WorldWideScience

Sample records for test automated methods

  1. Applications of Automation Methods for Nonlinear Fracture Test Analysis

    Science.gov (United States)

    Allen, Phillip A.; Wells, Douglas N.

    2013-01-01

    Using automated and standardized computer tools to calculate the pertinent test result values has several advantages such as: 1. allowing high-fidelity solutions to complex nonlinear phenomena that would be impractical to express in written equation form, 2. eliminating errors associated with the interpretation and programing of analysis procedures from the text of test standards, 3. lessening the need for expertise in the areas of solid mechanics, fracture mechanics, numerical methods, and/or finite element modeling, to achieve sound results, 4. and providing one computer tool and/or one set of solutions for all users for a more "standardized" answer. In summary, this approach allows a non-expert with rudimentary training to get the best practical solution based on the latest understanding with minimum difficulty.Other existing ASTM standards that cover complicated phenomena use standard computer programs: 1. ASTM C1340/C1340M-10- Standard Practice for Estimation of Heat Gain or Loss Through Ceilings Under Attics Containing Radiant Barriers by Use of a Computer Program 2. ASTM F 2815 - Standard Practice for Chemical Permeation through Protective Clothing Materials: Testing Data Analysis by Use of a Computer Program 3. ASTM E2807 - Standard Specification for 3D Imaging Data Exchange, Version 1.0 The verification, validation, and round-robin processes required of a computer tool closely parallel the methods that are used to ensure the solution validity for equations included in test standard. The use of automated analysis tools allows the creation and practical implementation of advanced fracture mechanics test standards that capture the physics of a nonlinear fracture mechanics problem without adding undue burden or expense to the user. The presented approach forms a bridge between the equation-based fracture testing standards of today and the next generation of standards solving complex problems through analysis automation.

  2. Comparison of three flaw-location methods for automated ultrasonic testing

    International Nuclear Information System (INIS)

    Seiger, H.

    1982-01-01

    Two well-known methods for locating flaws by measurement of the transit time of ultrasonic pulses are examined theoretically. It is shown that neither is sufficiently reliable for use in automated ultrasonic testing. A third method, which takes into account the shape of the sound field from the probe and the uncertainty in measurement of probe-flaw distance and probe position, is introduced. An experimental comparison of the three methods indicates that use of the advanced method results in more accurate location of flaws. (author)

  3. Automated ultrasonic testing--capabilities, limitations and methods

    International Nuclear Information System (INIS)

    Beller, L.S.; Mikesell, C.R.

    1977-01-01

    The requirements for precision and reproducibility of ultrasonic testing during inservice inspection of nuclear reactors are both quantitatively and qualitatively more severe than most current practice in the field can provide. An automated ultrasonic testing (AUT) system, which provides a significant advancement in field examination capabilities, is described. Properties of the system, its application, and typical results are discussed

  4. Automation of Test Cases for Web Applications : Automation of CRM Test Cases

    OpenAIRE

    Seyoum, Alazar

    2012-01-01

    The main theme of this project was to design a test automation framework for automating web related test cases. Automating test cases designed for testing a web interface provide a means of improving a software development process by shortening the testing phase in the software development life cycle. In this project an existing AutoTester framework and iMacros test automation tools were used. CRM Test Agent was developed to integrate AutoTester to iMacros and to enable the AutoTester,...

  5. Research on the Reliability Testing of Electrical Automation Control Equipment

    OpenAIRE

    Yongjie Luo

    2014-01-01

    According to the author’s many years’ work experience, this paper first discusses the concepts of electrical automation control equipment reliability testing, and then analyzes the test method of electrical automation control equipment reliability testing, finally, on this basis, this article discusses how to determine the reliability test method of electrical automation control equipment. Results of this study will provide a useful reference for electrical automation control equipment reliab...

  6. Automating Test Activities: Test Cases Creation, Test Execution, and Test Reporting with Multiple Test Automation Tools

    OpenAIRE

    Loke Mun Sei

    2015-01-01

    Software testing has become a mandatory process in assuring the software product quality. Hence, test management is needed in order to manage the test activities conducted in the software test life cycle. This paper discusses on the challenges faced in the software test life cycle, and how the test processes and test activities, mainly on test cases creation, test execution, and test reporting is being managed and automated using several test automation tools, i.e. Jira, ...

  7. Evaluating a method for automated rigid registration

    DEFF Research Database (Denmark)

    Darkner, Sune; Vester-Christensen, Martin; Larsen, Rasmus

    2007-01-01

    to point distance. T-test for common mean are used to determine the performance of the two methods (supported by a Wilcoxon signed rank test). The performance influence of sampling density, sampling quantity, and norms is analyzed using a similar method.......We evaluate a novel method for fully automated rigid registration of 2D manifolds in 3D space based on distance maps, the Gibbs sampler and Iterated Conditional Modes (ICM). The method is tested against the ICP considered as the gold standard for automated rigid registration. Furthermore...

  8. Semantics-based Automated Web Testing

    Directory of Open Access Journals (Sweden)

    Hai-Feng Guo

    2015-08-01

    Full Text Available We present TAO, a software testing tool performing automated test and oracle generation based on a semantic approach. TAO entangles grammar-based test generation with automated semantics evaluation using a denotational semantics framework. We show how TAO can be incorporated with the Selenium automation tool for automated web testing, and how TAO can be further extended to support automated delta debugging, where a failing web test script can be systematically reduced based on grammar-directed strategies. A real-life parking website is adopted throughout the paper to demonstrate the effectivity of our semantics-based web testing approach.

  9. Human-centered automation of testing, surveillance and maintenance

    International Nuclear Information System (INIS)

    Bhatt, S.C.; Sun, B.K.H.

    1991-01-01

    Manual surveillance and testing of instrumentation, control and protection systems at nuclear power plants involves system and human errors which can lead to substantial plant down time. Frequent manual testing can also contribute significantly to operation and maintenance cost. Automation technology offers potential for prudent applications at the power plant to reduce testing errors and cost. To help address the testing problems and to harness the benefit of automation application, input from utilities is obtained on suitable automation approaches. This paper includes lessens from successful past experience at a few plants where some island of automation exist. The results are summarized as a set of specifications for semi automatic testing. A human-centered automation methodology is proposed with the guidelines for optimal human/computer division of tasks given. Implementation obstacles for significant changes of testing practices are identified and methods acceptable to nuclear power plants for addressing these obstacles have been suggested

  10. Automate functional testing

    Directory of Open Access Journals (Sweden)

    Ramesh Kalindri

    2014-06-01

    Full Text Available Currently, software engineers are increasingly turning to the option of automating functional tests, but not always have successful in this endeavor. Reasons range from low planning until over cost in the process. Some principles that can guide teams in automating these tests are described in this article.

  11. Automation of diagnostic genetic testing: mutation detection by cyclic minisequencing.

    Science.gov (United States)

    Alagrund, Katariina; Orpana, Arto K

    2014-01-01

    The rising role of nucleic acid testing in clinical decision making is creating a need for efficient and automated diagnostic nucleic acid test platforms. Clinical use of nucleic acid testing sets demands for shorter turnaround times (TATs), lower production costs and robust, reliable methods that can easily adopt new test panels and is able to run rare tests in random access principle. Here we present a novel home-brew laboratory automation platform for diagnostic mutation testing. This platform is based on the cyclic minisequecing (cMS) and two color near-infrared (NIR) detection. Pipetting is automated using Tecan Freedom EVO pipetting robots and all assays are performed in 384-well micro plate format. The automation platform includes a data processing system, controlling all procedures, and automated patient result reporting to the hospital information system. We have found automated cMS a reliable, inexpensive and robust method for nucleic acid testing for a wide variety of diagnostic tests. The platform is currently in clinical use for over 80 mutations or polymorphisms. Additionally to tests performed from blood samples, the system performs also epigenetic test for the methylation of the MGMT gene promoter, and companion diagnostic tests for analysis of KRAS and BRAF gene mutations from formalin fixed and paraffin embedded tumor samples. Automation of genetic test reporting is found reliable and efficient decreasing the work load of academic personnel.

  12. Testing an Automated Accuracy Assessment Method on Bibliographic Data

    Directory of Open Access Journals (Sweden)

    Marlies Olensky

    2014-12-01

    Full Text Available This study investigates automated data accuracy assessment as described in data quality literature for its suitability to assess bibliographic data. The data samples comprise the publications of two Nobel Prize winners in the field of Chemistry for a 10-year-publication period retrieved from the two bibliometric data sources, Web of Science and Scopus. The bibliographic records are assessed against the original publication (gold standard and an automatic assessment method is compared to a manual one. The results show that the manual assessment method reflects truer accuracy scores. The automated assessment method would need to be extended by additional rules that reflect specific characteristics of bibliographic data. Both data sources had higher accuracy scores per field than accumulated per record. This study contributes to the research on finding a standardized assessment method of bibliographic data accuracy as well as defining the impact of data accuracy on the citation matching process.

  13. Automated Test-Form Generation

    Science.gov (United States)

    van der Linden, Wim J.; Diao, Qi

    2011-01-01

    In automated test assembly (ATA), the methodology of mixed-integer programming is used to select test items from an item bank to meet the specifications for a desired test form and optimize its measurement accuracy. The same methodology can be used to automate the formatting of the set of selected items into the actual test form. Three different…

  14. GUI test automation for Qt application

    OpenAIRE

    Wang, Lei

    2015-01-01

    GUI test automation is a popular and interesting subject in the testing industry. Many companies plan to start test automation projects in order to implement efficient, less expensive software testing. However, there are challenges for the testing team who lack experience performing GUI tests automation. Many GUI test automation projects have ended in failure due to mistakes made during the early stages of the project. The major work of this thesis is to find a solution to the challenges of e...

  15. Automation for a base station stability testing

    OpenAIRE

    Punnek, Elvis

    2016-01-01

    This Batchelor’s thesis was commissioned by Oy LM Ericsson Ab Oulu. The aim of it was to help to investigate and create a test automation solution for the stability testing of the LTE base station. The main objective was to create a test automation for a predefined test set. This test automation solution had to be created for specific environments and equipment. This work included creating the automation for the test cases and putting them to daily test automation jobs. The key factor...

  16. Integrating Test-Form Formatting into Automated Test Assembly

    Science.gov (United States)

    Diao, Qi; van der Linden, Wim J.

    2013-01-01

    Automated test assembly uses the methodology of mixed integer programming to select an optimal set of items from an item bank. Automated test-form generation uses the same methodology to optimally order the items and format the test form. From an optimization point of view, production of fully formatted test forms directly from the item pool using…

  17. Myths in test automation

    Directory of Open Access Journals (Sweden)

    Jazmine Francis

    2014-12-01

    Full Text Available Myths in automation of software testing is an issue of discussion that echoes about the areas of service in validation of software industry. Probably, the first though that appears in knowledgeable reader would be Why this old topic again? What's New to discuss the matter? But, for the first time everyone agrees that undoubtedly automation testing today is not today what it used to be ten or fifteen years ago, because it has evolved in scope and magnitude. What began as a simple linear scripts for web applications today has a complex architecture and a hybrid framework to facilitate the implementation of testing applications developed with various platforms and technologies. Undoubtedly automation has advanced, but so did the myths associated with it. The change in perspective and knowledge of people on automation has altered the terrain. This article reflects the points of views and experience of the author in what has to do with the transformation of the original myths in new versions, and how they are derived; also provides his thoughts on the new generation of myths.

  18. Myths in test automation

    Directory of Open Access Journals (Sweden)

    Jazmine Francis

    2015-01-01

    Full Text Available Myths in automation of software testing is an issue of discussion that echoes about the areas of service in validation of software industry. Probably, the first though that appears in knowledgeable reader would be Why this old topic again? What's New to discuss the matter? But, for the first time everyone agrees that undoubtedly automation testing today is not today what it used to be ten or fifteen years ago, because it has evolved in scope and magnitude. What began as a simple linear scripts for web applications today has a complex architecture and a hybrid framework to facilitate the implementation of testing applications developed with various platforms and technologies. Undoubtedly automation has advanced, but so did the myths associated with it. The change in perspective and knowledge of people on automation has altered the terrain. This article reflects the points of views and experience of the author in what has to do with the transformation of the original myths in new versions, and how they are derived; also provides his thoughts on the new generation of myths.

  19. Application of a path sensitizing method on automated generation of test specifications for control software

    International Nuclear Information System (INIS)

    Morimoto, Yuuichi; Fukuda, Mitsuko

    1995-01-01

    An automated generation method for test specifications has been developed for sequential control software in plant control equipment. Sequential control software can be represented as sequential circuits. The control software implemented in a control equipment is designed from these circuit diagrams. In logic tests of VLSI's, path sensitizing methods are widely used to generate test specifications. But the method generates test specifications at a single time only, and can not be directly applied to sequential control software. The basic idea of the proposed method is as follows. Specifications of each logic operator in the diagrams are defined in the software design process. Therefore, test specifications of each operator in the control software can be determined from these specifications, and validity of software can be judged by inspecting all of the operators in the logic circuit diagrams. Candidates for sensitized paths, on which test data for each operator propagates, can be generated by the path sensitizing method. To confirm feasibility of the method, it was experimentally applied to control software in digital control equipment. The program could generate test specifications exactly, and feasibility of the method was confirmed. (orig.) (3 refs., 7 figs.)

  20. NIF ICCS Test Controller for Automated and Manual Testing

    International Nuclear Information System (INIS)

    Zielinski, J S

    2007-01-01

    The National Ignition Facility (NIF) Integrated Computer Control System (ICCS) is a large (1.5 MSLOC), hierarchical, distributed system that controls all aspects of the NIF laser [1]. The ICCS team delivers software updates to the NIF facility throughout the year to support shot operations and commissioning activities. In 2006, there were 48 releases of ICCS: 29 full releases, 19 patches. To ensure the quality of each delivery, thousands of manual and automated tests are performed using the ICCS Test Controller test infrastructure. The TestController system provides test inventory management, test planning, automated test execution and manual test logging, release testing summaries and test results search, all through a web browser interface. Automated tests include command line based frameworks server tests and Graphical User Interface (GUI) based Java tests. Manual tests are presented as a checklist-style web form to be completed by the tester. The results of all tests, automated and manual, are kept in a common repository that provides data to dynamic status reports. As part of the 3-stage ICCS release testing strategy, the TestController system helps plan, evaluate and track the readiness of each release to the NIF facility

  1. 78 FR 53466 - Modification of Two National Customs Automation Program (NCAP) Tests Concerning Automated...

    Science.gov (United States)

    2013-08-29

    ... Customs Automation Program (NCAP) Tests Concerning Automated Commercial Environment (ACE) Document Image... National Customs Automation Program (NCAP) tests concerning document imaging, known as the Document Image... the National Customs Automation Program (NCAP) tests concerning document imaging, known as the...

  2. Automated [inservice testing] IST program

    International Nuclear Information System (INIS)

    Wright, W.M.

    1990-01-01

    There are two methods used to manage a Section XI program: Manual and Automated. The manual method usually consists of hand written records of test results and scheduling requirements. This method while initially lower in cost, results in problems later on in the life of a plant as data continues to accumulate. Automation allows instant access to forty years of test results. Due to the lower cost and higher performance of todays' personal computers, an automated method via a computer program provides an excellent method for managing the vast amount of data that accumulates over the forty year life of a plant. Through the use of a computer, special functions involving this data are available, which through a manual method would not be practical. This paper will describe some of the advantages in using a computer program to manage the Section XI 1ST program. The ISTBASE consists of program code and numerous databases. The source code is written and complied in CLIPPER (tm) language. Graphing routines are performed by dGE (tm) graphics library. Graphs are displayed in EGA form. Since it was estimated that the total complied code, would exceed 640K of ram, overlays through the use of modular programming were used to facilitate the DOS restrictions of 640K ram. The use of overlays still require the user to gain access to ISTBASE through the PASSWORD module. The database files are designed to be compatible with dBASE III+ (tm) data structure. This allows transfer of data between ISTBASE and other database managers/applications. A math co-processor is utilized to speed up calculations on graphs and other mathematical calculations. Program code and data files require a hard disk drive with at least 28 Meg capacity. While ISTBASE will execute on a 8088 based computer, an 80286 computer with a 12 MHz operating speed should be considered the minimum system configuration

  3. Comparison of Automated Graphical User Interface Testing Tools

    OpenAIRE

    Gaber, Domen

    2018-01-01

    The thesis presents the analysis of modern tools for automated testing of various web based user interfaces. The purpose of the work is to compare specific test automation solutions and point out the most suitable test automation tool amongst them. One of the main goals of test automation is to gain faster execution when compared to manual testing and overall cost deduction. There are multiple test automation solutions available on the market, which differ in complexity of use, type of o...

  4. Automation of Electrical Cable Harnesses Testing

    Directory of Open Access Journals (Sweden)

    Zhuming Bi

    2017-12-01

    Full Text Available Traditional automated systems, such as industrial robots, are applied in well-structured environments, and many automated systems have a limited adaptability to deal with complexity and uncertainty; therefore, the applications of industrial robots in small- and medium-sized enterprises (SMEs are very limited. The majority of manual operations in SMEs are too complicated for automation. The rapidly developed information technologies (IT has brought new opportunities for the automation of manufacturing and assembly processes in the ill-structured environments. Note that an automation solution should be designed to meet the given requirements of the specified application, and it differs from one application to another. In this paper, we look into the feasibility of automated testing for electric cable harnesses, and our focus is on some of the generic strategies for the improvement of the adaptability of automation solutions. Especially, the concept of modularization is adopted in developing hardware and software to maximize system adaptability in testing a wide scope of products. A proposed system has been implemented, and the system performances have been evaluated by executing tests on actual products. The testing experiments have shown that the automated system outperformed manual operations greatly in terms of cost-saving, productivity and reliability. Due to the potential of increasing system adaptability and cost reduction, the presented work has its theoretical and practical significance for an extension for other automation solutions in SMEs.

  5. Automated test data generation for branch testing using incremental

    Indian Academy of Sciences (India)

    Cost of software testing can be reduced by automated test data generation to find a minimal set of data that has maximum coverage. Search-based software testing (SBST) is one of the techniques recently used for automated testing task. SBST makes use of control flow graph (CFG) and meta-heuristic search algorithms to ...

  6. 78 FR 66039 - Modification of National Customs Automation Program Test Concerning Automated Commercial...

    Science.gov (United States)

    2013-11-04

    ... Customs Automation Program Test Concerning Automated Commercial Environment (ACE) Cargo Release (Formerly...) plan to both rename and modify the National Customs Automation Program (NCAP) test concerning the... data elements required to obtain release for cargo transported by air. The test will now be known as...

  7. Designing a Software Test Automation Framework

    Directory of Open Access Journals (Sweden)

    Sabina AMARICAI

    2014-01-01

    Full Text Available Testing is an art and science that should ultimately lead to lower cost businesses through increasing control and reducing risk. Testing specialists should thoroughly understand the system or application from both the technical and the business perspective, and then design, build and implement the minimum-cost, maximum-coverage validation framework. Test Automation is an important ingredient for testing large scale applications. In this paper we discuss several test automation frameworks, their advantages and disadvantages. We also propose a custom automation framework model that is suited for applications with very complex business requirements and numerous interfaces.

  8. Designing and implementing test automation frameworks with QTP

    CERN Document Server

    Bhargava, Ashish

    2013-01-01

    A tutorial-based approach, showing basic coding and designing techniques to build test automation frameworks.If you are a beginner, an automation engineer, an aspiring test automation engineer, a manual tester, a test lead or a test architect who wants to learn, create, and maintain test automation frameworks, this book will accelerate your ability to develop and adapt the framework.

  9. Automated Functional Testing based on the Navigation of Web Applications

    Directory of Open Access Journals (Sweden)

    Boni García

    2011-08-01

    Full Text Available Web applications are becoming more and more complex. Testing such applications is an intricate hard and time-consuming activity. Therefore, testing is often poorly performed or skipped by practitioners. Test automation can help to avoid this situation. Hence, this paper presents a novel approach to perform automated software testing for web applications based on its navigation. On the one hand, web navigation is the process of traversing a web application using a browser. On the other hand, functional requirements are actions that an application must do. Therefore, the evaluation of the correct navigation of web applications results in the assessment of the specified functional requirements. The proposed method to perform the automation is done in four levels: test case generation, test data derivation, test case execution, and test case reporting. This method is driven by three kinds of inputs: i UML models; ii Selenium scripts; iii XML files. We have implemented our approach in an open-source testing framework named Automatic Testing Platform. The validation of this work has been carried out by means of a case study, in which the target is a real invoice management system developed using a model-driven approach.

  10. Parallelize Automated Tests in a Build and Test Environment

    OpenAIRE

    Durairaj, Selva Ganesh

    2016-01-01

    This thesis investigates the possibilities of finding solutions, in order to reduce the total time spent for testing and waiting times for running multiple automated test cases in a test framework. The “Automated Test Framework”, developed by Axis Communications AB, is used to write the functional tests to test both hardware and software of a resource. The functional tests that tests the software is considered in this thesis work. In the current infrastructure, tests are executed sequentially...

  11. Development of Hardware and Software for Automated Ultrasonic Testing

    International Nuclear Information System (INIS)

    Choi, Sung Nam; Lee, Hee Jong; Yang, Seung Ok

    2012-01-01

    Nondestructive testing (NDT) for the construction and operating of NPPs plays an important role in confirming the integrity of the NPPs. Especially, Automated ultrasonic testing (AUT) is one of the primary nondestructive examination methods for in-service inspection of the welding parts in major components in NPPs. AUT is a reliable nondestructive testing because the data of AUT are saved and reviewed with other examiners. Korea Hydro and Nuclear Power-Central Research Institute (KHNP-CRI) has developed an automated ultrasonic testing (AUT) system based on a high speed pulser-receiver. In combination with the designed software and hardware architecture, this new system permits user configurations for a wide range of user-specific applications through fully automated inspections using compact portable systems with up to eight channels. This paper gives an overview of hardware (H/W) and software (S/W) for the AUT system to inspect welds in NPPs

  12. Automated Test Methods for XML Metadata

    Science.gov (United States)

    2017-12-28

    8933 Com (661) 277 8933 email jon.morgan.2.ctr@us.af.mil Secretariat, Range Commanders Council ATTN: TEDT-WS-RCC 1510 Headquarters Avenue White...Sands Missile Range, New Mexico 88002-5110 Phone: DSN 258-1107 Com (575) 678-1107 Fax: DSN 258-7519 Com (575) 678-7519 email ...Method for Testing Syntax The test method is as follows. 1. Initialize the programming environment. 2. Write test application code to use the

  13. 77 FR 48527 - National Customs Automation Program (NCAP) Test Concerning Automated Commercial Environment (ACE...

    Science.gov (United States)

    2012-08-14

    ... National Customs Automation Program (NCAP) test concerning the simplified entry functionality in the... DEPARTMENT OF HOMELAND SECURITY U.S. Customs and Border Protection National Customs Automation Program (NCAP) Test Concerning Automated Commercial Environment (ACE) Simplified Entry: Modification of...

  14. Automated Testing of Event-Driven Applications

    DEFF Research Database (Denmark)

    Jensen, Casper Svenning

    may be tested by selecting an interesting input (i.e. a sequence of events), and deciding if a failure occurs when the selected input is applied to the event-driven application under test. Automated testing promises to reduce the workload for developers by automatically selecting interesting inputs...... and detect failures. However, it is non-trivial to conduct automated testing of event-driven applications because of, for example, infinite input spaces and the absence of specifications of correct application behavior. In this PhD dissertation, we identify a number of specific challenges when conducting...... automated testing of event-driven applications, and we present novel techniques for solving these challenges. First, we present an algorithm for stateless model-checking of event-driven applications with partial-order reduction, and we show how this algorithm may be used to systematically test web...

  15. Launch Control System Software Development System Automation Testing

    Science.gov (United States)

    Hwang, Andrew

    2017-01-01

    The Spaceport Command and Control System (SCCS) is the National Aeronautics and Space Administration's (NASA) launch control system for the Orion capsule and Space Launch System, the next generation manned rocket currently in development. This system requires high quality testing that will measure and test the capabilities of the system. For the past two years, the Exploration and Operations Division at Kennedy Space Center (KSC) has assigned a group including interns and full-time engineers to develop automated tests to save the project time and money. The team worked on automating the testing process for the SCCS GUI that would use streamed simulated data from the testing servers to produce data, plots, statuses, etc. to the GUI. The software used to develop automated tests included an automated testing framework and an automation library. The automated testing framework has a tabular-style syntax, which means the functionality of a line of code must have the appropriate number of tabs for the line to function as intended. The header section contains either paths to custom resources or the names of libraries being used. The automation library contains functionality to automate anything that appears on a desired screen with the use of image recognition software to detect and control GUI components. The data section contains any data values strictly created for the current testing file. The body section holds the tests that are being run. The function section can include any number of functions that may be used by the current testing file or any other file that resources it. The resources and body section are required for all test files; the data and function sections can be left empty if the data values and functions being used are from a resourced library or another file. To help equip the automation team with better tools, the Project Lead of the Automated Testing Team, Jason Kapusta, assigned the task to install and train an optical character recognition (OCR

  16. Automated Test Case Generation

    CERN Multimedia

    CERN. Geneva

    2015-01-01

    I would like to present the concept of automated test case generation. I work on it as part of my PhD and I think it would be interesting also for other people. It is also the topic of a workshop paper that I am introducing in Paris. (abstract below) Please note that the talk itself would be more general and not about the specifics of my PhD, but about the broad field of Automated Test Case Generation. I would introduce the main approaches (combinatorial testing, symbolic execution, adaptive random testing) and their advantages and problems. (oracle problem, combinatorial explosion, ...) Abstract of the paper: Over the last decade code-based test case generation techniques such as combinatorial testing or dynamic symbolic execution have seen growing research popularity. Most algorithms and tool implementations are based on finding assignments for input parameter values in order to maximise the execution branch coverage. Only few of them consider dependencies from outside the Code Under Test’s scope such...

  17. Instant Sikuli test automation

    CERN Document Server

    Lau, Ben

    2013-01-01

    Get to grips with a new technology, understand what it is and what it can do for you, and then get to work with the most important features and tasks. A concise guide written in an easy-to follow style using the Starter guide approach.This book is aimed at automation and testing professionals who want to use Sikuli to automate GUI. Some Python programming experience is assumed.

  18. 78 FR 44142 - Modification of Two National Customs Automation Program (NCAP) Tests Concerning Automated...

    Science.gov (United States)

    2013-07-23

    ... Customs Automation Program (NCAP) Tests Concerning Automated Commercial Environment (ACE) Document Image... (CBP's) plan to modify the National Customs Automation Program (NCAP) tests concerning document imaging... entry process by reducing the number of data elements required to obtain release for cargo transported...

  19. 21 CFR 864.9300 - Automated Coombs test systems.

    Science.gov (United States)

    2010-04-01

    ... Blood and Blood Products § 864.9300 Automated Coombs test systems. (a) Identification. An automated Coombs test system is a device used to detect and identify antibodies in patient sera or antibodies bound... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Automated Coombs test systems. 864.9300 Section...

  20. 76 FR 34246 - Automated Commercial Environment (ACE); Announcement of National Customs Automation Program Test...

    Science.gov (United States)

    2011-06-13

    ... Environment (ACE); Announcement of National Customs Automation Program Test of Automated Procedures for In... Customs Automation Program (NCAP) test relating to highway movements of commercial goods that are transported in-bond through the United States from one point in Canada to another point in Canada. The NCAP...

  1. Test Automation Process Improvement A case study of BroadSoft

    OpenAIRE

    Gummadi, Jalendar

    2016-01-01

    This master thesis research is about improvement of test automation process at BroadSoft Finland as a case study. Test automation project recently started at BroadSoft but the project is not properly integrated in to existing process. Project is about converting manual test cases to automation test cases. The aim of this thesis is about studying existing BroadSoft test process and studying different test automation frameworks. In this thesis different test automation process are studied ...

  2. Non-destructive automated express method for determining the inclination of chromium-nickel steels IGC

    International Nuclear Information System (INIS)

    Nazarov, A.A.; Kamenev, Yu.B.; Kuusk, L.V.; Kormin, E.G.; Vasil'ev, A.N.; Sumbaeva, T.E.

    1986-01-01

    Methods of automated control of 18-10-type steel inclination to IGC are developed and a corresponding automated testing complex (ATS) is created. 08Kh18N10T steel samples had two variants of thermal treatment: 1) 1200 deg (5 h), 600 deg (50 h); 2) 1200 deg (5 h). Methods of non-destructive automated control of 18-10-type steel inclination to IGC are developed on the basis of potentiodynamic reactivation (PR) principle. Automated testing complex is developed, which has undergone experimental running and demonstrated a high confidence of results, reliability and easy operation

  3. Test/score/report: Simulation techniques for automating the test process

    Science.gov (United States)

    Hageman, Barbara H.; Sigman, Clayton B.; Koslosky, John T.

    1994-01-01

    A Test/Score/Report capability is currently being developed for the Transportable Payload Operations Control Center (TPOCC) Advanced Spacecraft Simulator (TASS) system which will automate testing of the Goddard Space Flight Center (GSFC) Payload Operations Control Center (POCC) and Mission Operations Center (MOC) software in three areas: telemetry decommutation, spacecraft command processing, and spacecraft memory load and dump processing. Automated computer control of the acceptance test process is one of the primary goals of a test team. With the proper simulation tools and user interface, the task of acceptance testing, regression testing, and repeatability of specific test procedures of a ground data system can be a simpler task. Ideally, the goal for complete automation would be to plug the operational deliverable into the simulator, press the start button, execute the test procedure, accumulate and analyze the data, score the results, and report the results to the test team along with a go/no recommendation to the test team. In practice, this may not be possible because of inadequate test tools, pressures of schedules, limited resources, etc. Most tests are accomplished using a certain degree of automation and test procedures that are labor intensive. This paper discusses some simulation techniques that can improve the automation of the test process. The TASS system tests the POCC/MOC software and provides a score based on the test results. The TASS system displays statistics on the success of the POCC/MOC system processing in each of the three areas as well as event messages pertaining to the Test/Score/Report processing. The TASS system also provides formatted reports documenting each step performed during the tests and the results of each step. A prototype of the Test/Score/Report capability is available and currently being used to test some POCC/MOC software deliveries. When this capability is fully operational it should greatly reduce the time necessary

  4. Automation of the testing procedure

    International Nuclear Information System (INIS)

    Haas, H.; Fleischer, M.; Bachner, E.

    1979-01-01

    For the judgement of technologies applied and the testing of specific components of the HTR primary circuit, complex test procedures and data evaluations are required. Extensive automation of these test procedures is indispensable. (orig.) [de

  5. Automated methods of corrosion measurement

    DEFF Research Database (Denmark)

    Andersen, Jens Enevold Thaulov; Bech-Nielsen, Gregers; Reeve, John Ch

    1997-01-01

    to revise assumptions regarding the basis of the method, which sometimes leads to the discovery of as-yet unnoticed phenomena. The present selection of automated methods for corrosion measurements is not motivated simply by the fact that a certain measurement can be performed automatically. Automation...... is applied to nearly all types of measurements today....

  6. Spaceport Command and Control System Automation Testing

    Science.gov (United States)

    Hwang, Andrew

    2017-01-01

    The Spaceport Command and Control System (SCCS) is the National Aeronautics and Space Administrations (NASA) launch control system for the Orion capsule and Space Launch System, the next generation manned rocket currently in development. This large system requires high quality testing that will properly measure the capabilities of the system. Automating the test procedures would save the project time and money. Therefore, the Electrical Engineering Division at Kennedy Space Center (KSC) has recruited interns for the past two years to work alongside full-time engineers to develop these automated tests, as well as innovate upon the current automation process.

  7. Spaceport Command and Control System Automated Testing

    Science.gov (United States)

    Stein, Meriel

    2017-01-01

    The Spaceport Command and Control System (SCCS) is the National Aeronautics and Space Administrations (NASA) launch control system for the Orion capsule and Space Launch System, the next generation manned rocket currently in development. This large system requires high quality testing that will properly measure the capabilities of the system. Automating the test procedures would save the project time and money. Therefore, the Electrical Engineering Division at Kennedy Space Center (KSC) has recruited interns for the past two years to work alongside full-time engineers to develop these automated tests, as well as innovate upon the current automation process.

  8. A test matrix sequencer for research test facility automation

    Science.gov (United States)

    Mccartney, Timothy P.; Emery, Edward F.

    1990-01-01

    The hardware and software configuration of a Test Matrix Sequencer, a general purpose test matrix profiler that was developed for research test facility automation at the NASA Lewis Research Center, is described. The system provides set points to controllers and contact closures to data systems during the course of a test. The Test Matrix Sequencer consists of a microprocessor controlled system which is operated from a personal computer. The software program, which is the main element of the overall system is interactive and menu driven with pop-up windows and help screens. Analog and digital input/output channels can be controlled from a personal computer using the software program. The Test Matrix Sequencer provides more efficient use of aeronautics test facilities by automating repetitive tasks that were once done manually.

  9. Automated Methods of Corrosion Measurements

    DEFF Research Database (Denmark)

    Andersen, Jens Enevold Thaulov

    1997-01-01

    . Mechanical control, recording, and data processing must therefore be automated to a high level of precision and reliability. These general techniques and the apparatus involved have been described extensively. The automated methods of such high-resolution microscopy coordinated with computerized...

  10. An automated method for the layup of fiberglass fabric

    Science.gov (United States)

    Zhu, Siqi

    This dissertation presents an automated composite fabric layup solution based on a new method to deform fiberglass fabric referred to as shifting. A layup system was designed and implemented using a large robotic gantry and custom end-effector for shifting. Layup tests proved that the system can deposit fabric onto two-dimensional and three-dimensional tooling surfaces accurately and repeatedly while avoiding out-of-plane deformation. A process planning method was developed to generate tool paths for the layup system based on a geometric model of the tooling surface. The approach is analogous to Computer Numerical Controlled (CNC) machining, where Numerical Control (NC) code from a Computer-Aided Design (CAD) model is generated to drive the milling machine. Layup experiments utilizing the proposed method were conducted to validate the performance. The results show that the process planning software requires minimal time or human intervention and can generate tool paths leading to accurate composite fabric layups. Fiberglass fabric samples processed with shifting deformation were observed for meso-scale deformation. Tow thinning, bending and spacing was observed and measured. Overall, shifting did not create flaws in amounts that would disqualify the method from use in industry. This suggests that shifting is a viable method for use in automated manufacturing. The work of this dissertation provides a new method for the automated layup of broad width composite fabric that is not possible with any available composite automation systems to date.

  11. Automated touch sensing in the mouse tapered beam test using Raspberry Pi.

    Science.gov (United States)

    Ardesch, Dirk Jan; Balbi, Matilde; Murphy, Timothy H

    2017-11-01

    Rodent models of neurological disease such as stroke are often characterized by motor deficits. One of the tests that are used to assess these motor deficits is the tapered beam test, which provides a sensitive measure of bilateral motor function based on foot faults (slips) made by a rodent traversing a gradually narrowing beam. However, manual frame-by-frame scoring of video recordings is necessary to obtain test results, which is time-consuming and prone to human rater bias. We present a cost-effective method for automated touch sensing in the tapered beam test. Capacitive touch sensors detect foot faults onto the beam through a layer of conductive paint, and results are processed and stored on a Raspberry Pi computer. Automated touch sensing using this method achieved high sensitivity (96.2%) as compared to 'gold standard' manual video scoring. Furthermore, it provided a reliable measure of lateralized motor deficits in mice with unilateral photothrombotic stroke: results indicated an increased number of contralesional foot faults for up to 6days after ischemia. The automated adaptation of the tapered beam test produces results immediately after each trial, without the need for labor-intensive post-hoc video scoring. It also increases objectivity of the data as it requires less experimenter involvement during analysis. Automated touch sensing may provide a useful adaptation to the existing tapered beam test in mice, while the simplicity of the hardware lends itself to potential further adaptations to related behavioral tests. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Automated damage test facilities for materials development and production optic quality assurance at Lawrence Livermore National Laboratory

    International Nuclear Information System (INIS)

    Battersby, C.; Dickson, R.; Jennings, R.; Kimmons, J.; Kozlowski, M. R.; Maricle, S.; Mouser, R.; Runkel, M.; Schwartz, S.; Sheehan, L. M.; Weinzapfel, C.

    1998-01-01

    The Laser Program at LLNL has developed automated facilities for damage testing optics up to 1 meter in diameter. The systems were developed to characterize the statistical distribution of localized damage performance across large-aperture National Ignition Facility optics. Full aperture testing is a key component of the quality assurance program for several of the optical components. The primary damage testing methods used are R:1 mapping and raster scanning. Automation of these test methods was required to meet the optics manufacturing schedule. The automated activities include control and diagnosis of the damage-test laser beam as well as detection and characterization of damage events

  13. Toponomics method for the automated quantification of membrane protein translocation.

    Science.gov (United States)

    Domanova, Olga; Borbe, Stefan; Mühlfeld, Stefanie; Becker, Martin; Kubitz, Ralf; Häussinger, Dieter; Berlage, Thomas

    2011-09-19

    Intra-cellular and inter-cellular protein translocation can be observed by microscopic imaging of tissue sections prepared immunohistochemically. A manual densitometric analysis is time-consuming, subjective and error-prone. An automated quantification is faster, more reproducible, and should yield results comparable to manual evaluation. The automated method presented here was developed on rat liver tissue sections to study the translocation of bile salt transport proteins in hepatocytes. For validation, the cholestatic liver state was compared to the normal biological state. An automated quantification method was developed to analyze the translocation of membrane proteins and evaluated in comparison to an established manual method. Firstly, regions of interest (membrane fragments) are identified in confocal microscopy images. Further, densitometric intensity profiles are extracted orthogonally to membrane fragments, following the direction from the plasma membrane to cytoplasm. Finally, several different quantitative descriptors were derived from the densitometric profiles and were compared regarding their statistical significance with respect to the transport protein distribution. Stable performance, robustness and reproducibility were tested using several independent experimental datasets. A fully automated workflow for the information extraction and statistical evaluation has been developed and produces robust results. New descriptors for the intensity distribution profiles were found to be more discriminative, i.e. more significant, than those used in previous research publications for the translocation quantification. The slow manual calculation can be substituted by the fast and unbiased automated method.

  14. A method for automated processing of measurement information during mechanical drilling

    Energy Technology Data Exchange (ETDEWEB)

    Samonenko, V.I.; Belinkov, V.G.; Romanova, L.A.

    1984-01-01

    An algorithm is cited for a developed method for automated processing of measurement information during mechanical drilling. Its use in conditions of operation of an automated control system (ASU) from drilling will make it possible to precisely identify a change in the lithology, the physical and mechanical and the abrasive properties, in the stratum (pore) pressure in the rock being drilled out during mechanical drilling, which along with other methods for testing the drilling process will increase the reliability of the decisions made.

  15. Exploratory analysis of methods for automated classification of laboratory test orders into syndromic groups in veterinary medicine.

    Directory of Open Access Journals (Sweden)

    Fernanda C Dórea

    Full Text Available BACKGROUND: Recent focus on earlier detection of pathogen introduction in human and animal populations has led to the development of surveillance systems based on automated monitoring of health data. Real- or near real-time monitoring of pre-diagnostic data requires automated classification of records into syndromes--syndromic surveillance--using algorithms that incorporate medical knowledge in a reliable and efficient way, while remaining comprehensible to end users. METHODS: This paper describes the application of two of machine learning (Naïve Bayes and Decision Trees and rule-based methods to extract syndromic information from laboratory test requests submitted to a veterinary diagnostic laboratory. RESULTS: High performance (F1-macro = 0.9995 was achieved through the use of a rule-based syndrome classifier, based on rule induction followed by manual modification during the construction phase, which also resulted in clear interpretability of the resulting classification process. An unmodified rule induction algorithm achieved an F(1-micro score of 0.979 though this fell to 0.677 when performance for individual classes was averaged in an unweighted manner (F(1-macro, due to the fact that the algorithm failed to learn 3 of the 16 classes from the training set. Decision Trees showed equal interpretability to the rule-based approaches, but achieved an F(1-micro score of 0.923 (falling to 0.311 when classes are given equal weight. A Naïve Bayes classifier learned all classes and achieved high performance (F(1-micro= 0.994 and F(1-macro = .955, however the classification process is not transparent to the domain experts. CONCLUSION: The use of a manually customised rule set allowed for the development of a system for classification of laboratory tests into syndromic groups with very high performance, and high interpretability by the domain experts. Further research is required to develop internal validation rules in order to establish

  16. Automated Test Case Generation for an Autopilot Requirement Prototype

    Science.gov (United States)

    Giannakopoulou, Dimitra; Rungta, Neha; Feary, Michael

    2011-01-01

    Designing safety-critical automation with robust human interaction is a difficult task that is susceptible to a number of known Human-Automation Interaction (HAI) vulnerabilities. It is therefore essential to develop automated tools that provide support both in the design and rapid evaluation of such automation. The Automation Design and Evaluation Prototyping Toolset (ADEPT) enables the rapid development of an executable specification for automation behavior and user interaction. ADEPT supports a number of analysis capabilities, thus enabling the detection of HAI vulnerabilities early in the design process, when modifications are less costly. In this paper, we advocate the introduction of a new capability to model-based prototyping tools such as ADEPT. The new capability is based on symbolic execution that allows us to automatically generate quality test suites based on the system design. Symbolic execution is used to generate both user input and test oracles user input drives the testing of the system implementation, and test oracles ensure that the system behaves as designed. We present early results in the context of a component in the Autopilot system modeled in ADEPT, and discuss the challenges of test case generation in the HAI domain.

  17. Point-of-Care Test Equipment for Flexible Laboratory Automation.

    Science.gov (United States)

    You, Won Suk; Park, Jae Jun; Jin, Sung Moon; Ryew, Sung Moo; Choi, Hyouk Ryeol

    2014-08-01

    Blood tests are some of the core clinical laboratory tests for diagnosing patients. In hospitals, an automated process called total laboratory automation, which relies on a set of sophisticated equipment, is normally adopted for blood tests. Noting that the total laboratory automation system typically requires a large footprint and significant amount of power, slim and easy-to-move blood test equipment is necessary for specific demands such as emergency departments or small-size local clinics. In this article, we present a point-of-care test system that can provide flexibility and portability with low cost. First, the system components, including a reagent tray, dispensing module, microfluidic disk rotor, and photometry scanner, and their functions are explained. Then, a scheduler algorithm to provide a point-of-care test platform with an efficient test schedule to reduce test time is introduced. Finally, the results of diagnostic tests are presented to evaluate the system. © 2014 Society for Laboratory Automation and Screening.

  18. Optimization of automation: I. Estimation method of cognitive automation rates reflecting the effects of automation on human operators in nuclear power plants

    International Nuclear Information System (INIS)

    Lee, Seung Min; Kim, Jong Hyun; Seong, Poong Hyun

    2014-01-01

    Highlights: • We propose an estimation method of the automation rate by taking the advantages of automation as the estimation measures. • We conduct the experiments to examine the validity of the suggested method. • The higher the cognitive automation rate is, the greater the decreased rate of the working time will be. • The usefulness of the suggested estimation method is proved by statistical analyses. - Abstract: Since automation was introduced in various industrial fields, the concept of the automation rate has been used to indicate the inclusion proportion of automation among all work processes or facilities. Expressions of the inclusion proportion of automation are predictable, as is the ability to express the degree of the enhancement of human performance. However, many researchers have found that a high automation rate does not guarantee high performance. Therefore, to reflect the effects of automation on human performance, this paper proposes a new estimation method of the automation rate that considers the effects of automation on human operators in nuclear power plants (NPPs). Automation in NPPs can be divided into two types: system automation and cognitive automation. Some general descriptions and characteristics of each type of automation are provided, and the advantages of automation are investigated. The advantages of each type of automation are used as measures of the estimation method of the automation rate. One advantage was found to be a reduction in the number of tasks, and another was a reduction in human cognitive task loads. The system and the cognitive automation rate were proposed as quantitative measures by taking advantage of the aforementioned benefits. To quantify the required human cognitive task loads and thus suggest the cognitive automation rate, Conant’s information-theory-based model was applied. The validity of the suggested method, especially as regards the cognitive automation rate, was proven by conducting

  19. Design and Achievement of User Interface Automation Testing of Linux Based on Element Tree of DogTail

    Directory of Open Access Journals (Sweden)

    Yuan Wen-Chao

    2017-01-01

    Full Text Available As Linux gets more popular around the world, the advantage of the open source on software makes people do automated UI test by unified testing framework. UI software testing can guarantee the rationality of User Interface of Linux and accuracy of the UI’s widgets. In order to set free from fuzzy and repeated manual testing, and improve efficiency, this paper achieves automation testing of UI under Linux, and proposes a method to identify and test UI widgets under Linux, which is according to element tree of DogTail automaton testing framework. It achieves automation test of UI under Linux. According to this method, Aiming at the product of Red Hat Subscription Manager under Red Hat Enterprise Linux, it designs the automation test plan of this series of product’s dialogs. After many tests, it is indicated that this plan can identify UI widgets accurately and rationally, describe the structure of software clearly, avoid software errors and improve efficiency of the software. Simultaneously, it also can be used in the internationalization testing for checking translation during software internationalization.

  20. Methods for sorting out the defects according to size in automated ultrasonic testing of large-diameter thin-walled tubes

    International Nuclear Information System (INIS)

    Golovkin, A.M.; Matveev, A.S

    1977-01-01

    Two methods have been considered of identifying defects according to their size in the course of an automated ultrasonic testing, namely, according to the echo-signal amplitude, and according to the conventional depth of a defect. The peculiar features of the second method are analyzed, and its equivalence to the first one is proved. For the purpose of identifying defects according to their conventional width, a technique is suggested of standartizing flaw detectors according to the control reflectors of two sizes

  1. Operational Based Vision Assessment Automated Vision Test Collection User Guide

    Science.gov (United States)

    2017-05-15

    AFRL-SA-WP-SR-2017-0012 Operational Based Vision Assessment Automated Vision Test Collection User Guide Elizabeth Shoda, Alex...June 2015 – May 2017 4. TITLE AND SUBTITLE Operational Based Vision Assessment Automated Vision Test Collection User Guide 5a. CONTRACT NUMBER... automated vision tests , or AVT. Development of the AVT was required to support threshold-level vision testing capability needed to investigate the

  2. Automated quality control methods for sensor data: a novel observatory approach

    Directory of Open Access Journals (Sweden)

    J. R. Taylor

    2013-07-01

    Full Text Available National and international networks and observatories of terrestrial-based sensors are emerging rapidly. As such, there is demand for a standardized approach to data quality control, as well as interoperability of data among sensor networks. The National Ecological Observatory Network (NEON has begun constructing their first terrestrial observing sites, with 60 locations expected to be distributed across the US by 2017. This will result in over 14 000 automated sensors recording more than > 100 Tb of data per year. These data are then used to create other datasets and subsequent "higher-level" data products. In anticipation of this challenge, an overall data quality assurance plan has been developed and the first suite of data quality control measures defined. This data-driven approach focuses on automated methods for defining a suite of plausibility test parameter thresholds. Specifically, these plausibility tests scrutinize the data range and variance of each measurement type by employing a suite of binary checks. The statistical basis for each of these tests is developed, and the methods for calculating test parameter thresholds are explored here. While these tests have been used elsewhere, we apply them in a novel approach by calculating their relevant test parameter thresholds. Finally, implementing automated quality control is demonstrated with preliminary data from a NEON prototype site.

  3. Optimization of automation: III. Development of optimization method for determining automation rate in nuclear power plants

    International Nuclear Information System (INIS)

    Lee, Seung Min; Kim, Jong Hyun; Kim, Man Cheol; Seong, Poong Hyun

    2016-01-01

    Highlights: • We propose an appropriate automation rate that enables the best human performance. • We analyze the shortest working time considering Situation Awareness Recovery (SAR). • The optimized automation rate is estimated by integrating the automation and ostracism rate estimation methods. • The process to derive the optimized automation rate is demonstrated through case studies. - Abstract: Automation has been introduced in various industries, including the nuclear field, because it is commonly believed that automation promises greater efficiency, lower workloads, and fewer operator errors through reducing operator errors and enhancing operator and system performance. However, the excessive introduction of automation has deteriorated operator performance due to the side effects of automation, which are referred to as Out-of-the-Loop (OOTL), and this is critical issue that must be resolved. Thus, in order to determine the optimal level of automation introduction that assures the best human operator performance, a quantitative method of optimizing the automation is proposed in this paper. In order to propose the optimization method for determining appropriate automation levels that enable the best human performance, the automation rate and ostracism rate, which are estimation methods that quantitatively analyze the positive and negative effects of automation, respectively, are integrated. The integration was conducted in order to derive the shortest working time through considering the concept of situation awareness recovery (SAR), which states that the automation rate with the shortest working time assures the best human performance. The process to derive the optimized automation rate is demonstrated through an emergency operation scenario-based case study. In this case study, four types of procedures are assumed through redesigning the original emergency operating procedure according to the introduced automation and ostracism levels. Using the

  4. Automation of unit for leakage test

    OpenAIRE

    LYCHKOVSKAYA V.S.; TSYGANKOV A.S.; GRINBERG G.M.; STANOVOVA O.A.

    2015-01-01

    Federal state educational standard requirements for training of university students have been considered. Leakage test procedures for components of aerospace vehicles have been described. Automation procedures of existing laboratory leakage test units have been outlined.

  5. Formal Test Automation: A Simple Experiment

    NARCIS (Netherlands)

    Belinfante, Axel; Feenstra, J.; de Vries, R.G.; Tretmans, G.J.; Goga, N.; Feijs, Loe; Mauw, Sjouke; Heerink, A.W.; Csopaki, Gyula; Dibuz, Sarolta; Tarnay, Katalin

    1999-01-01

    In this paper1 we study the automation of test derivation and execution in the area of conformance testing. The test scenarios are derived from multiple specication languages: LOTOS, Promela and SDL. A central theme of this study is the usability of batch-oriented and on-the-fly testing approaches.

  6. Automation of electromagnetic compatability (EMC) test facilities

    Science.gov (United States)

    Harrison, C. A.

    1986-01-01

    Efforts to automate electromagnetic compatibility (EMC) test facilities at Marshall Space Flight Center are discussed. The present facility is used to accomplish a battery of nine standard tests (with limited variations) deigned to certify EMC of Shuttle payload equipment. Prior to this project, some EMC tests were partially automated, but others were performed manually. Software was developed to integrate all testing by means of a desk-top computer-controller. Near real-time data reduction and onboard graphics capabilities permit immediate assessment of test results. Provisions for disk storage of test data permit computer production of the test engineer's certification report. Software flexibility permits variation in the tests procedure, the ability to examine more closely those frequency bands which indicate compatibility problems, and the capability to incorporate additional test procedures.

  7. Comparison of Size Modulation Standard Automated Perimetry and Conventional Standard Automated Perimetry with a 10-2 Test Program in Glaucoma Patients.

    Science.gov (United States)

    Hirasawa, Kazunori; Takahashi, Natsumi; Satou, Tsukasa; Kasahara, Masayuki; Matsumura, Kazuhiro; Shoji, Nobuyuki

    2017-08-01

    This prospective observational study compared the performance of size modulation standard automated perimetry with the Octopus 600 10-2 test program, with stimulus size modulation during testing, based on stimulus intensity and conventional standard automated perimetry, with that of the Humphrey 10-2 test program in glaucoma patients. Eighty-seven eyes of 87 glaucoma patients underwent size modulation standard automated perimetry with Dynamic strategy and conventional standard automated perimetry using the SITA standard strategy. The main outcome measures were global indices, point-wise threshold, visual defect size and depth, reliability indices, and test duration; these were compared between size modulation standard automated perimetry and conventional standard automated perimetry. Global indices and point-wise threshold values between size modulation standard automated perimetry and conventional standard automated perimetry were moderately to strongly correlated (p 33.40, p modulation standard automated perimetry than with conventional standard automated perimetry, but the visual-field defect size was smaller (p modulation-standard automated perimetry than on conventional standard automated perimetry. The reliability indices, particularly the false-negative response, of size modulation standard automated perimetry were worse than those of conventional standard automated perimetry (p modulation standard automated perimetry than with conventional standard automated perimetry (p = 0.02). Global indices and the point-wise threshold value of the two testing modalities correlated well. However, the potential of a large stimulus presented at an area with a decreased sensitivity with size modulation standard automated perimetry could underestimate the actual threshold in the 10-2 test protocol, as compared with conventional standard automated perimetry.

  8. Test Results for the Automated Rendezvous and Capture System

    Science.gov (United States)

    Cruzen, Craig; Dabney, Richard; Lomas, James

    1999-01-01

    The Automated Rendezvous and Capture (AR&C) system was designed and tested at NASA's Marshall Space Flight Center (MSFC) to demonstrate technologies and mission strategies for automated rendezvous and docking of spacecraft in Earth orbit, The system incorporates some of the latest innovations in Global Positioning, System space navigation, laser sensor technologies and automated mission sequencing algorithms. The system's initial design and integration was completed in 1998 and has undergone testing at MSFC. This paper describes the major components of the AR&C system and presents results from the official system tests performed in MSFC's Flight Robotics Laboratory with digital simulations and hardware in the loop tests. The results show that the AR&C system can safely and reliably perform automated rendezvous and docking missions in the absence of system failures with 100 percent success. When system failures are included, the system uses its automated collision avoidance maneuver logic to recover in a safe manner. The primary objective of the AR&C project is to prove that by designing a safe and robust automated system, mission operations cost can be reduced by decreasing the personnel required for mission design, preflight planning and training required for crewed rendezvous and docking missions.

  9. The automated testing system of programs with the graphic user interface within the context of educational process

    OpenAIRE

    Sychev, O.; Kiryushkin, A.

    2009-01-01

    The paper describes the problems of automation of educational process at the course "Programming on high level language. Algorithmic languages". Complexities of testing of programs with the user interface are marked. Existing analogues was considered. Methods of automation of student's jobs testing are offered.

  10. Model-based automated testing of critical PLC programs.

    CERN Document Server

    Fernández Adiego, B; Tournier, J-C; González Suárez, V M; Bliudze, S

    2014-01-01

    Testing of critical PLC (Programmable Logic Controller) programs remains a challenging task for control system engineers as it can rarely be automated. This paper proposes a model based approach which uses the BIP (Behavior, Interactions and Priorities) framework to perform automated testing of PLC programs developed with the UNICOS (UNified Industrial COntrol System) framework. This paper defines the translation procedure and rules from UNICOS to BIP which can be fully automated in order to hide the complexity of the underlying model from the control engineers. The approach is illustrated and validated through the study of a water treatment process.

  11. Automated particulate sampler field test model operations guide

    Energy Technology Data Exchange (ETDEWEB)

    Bowyer, S.M.; Miley, H.S.

    1996-10-01

    The Automated Particulate Sampler Field Test Model Operations Guide is a collection of documents which provides a complete picture of the Automated Particulate Sampler (APS) and the Field Test in which it was evaluated. The Pacific Northwest National Laboratory (PNNL) Automated Particulate Sampler was developed for the purpose of radionuclide particulate monitoring for use under the Comprehensive Test Ban Treaty (CTBT). Its design was directed by anticipated requirements of small size, low power consumption, low noise level, fully automatic operation, and most predominantly the sensitivity requirements of the Conference on Disarmament Working Paper 224 (CDWP224). This guide is intended to serve as both a reference document for the APS and to provide detailed instructions on how to operate the sampler. This document provides a complete description of the APS Field Test Model and all the activity related to its evaluation and progression.

  12. High-throughput in vivo genotoxicity testing: an automated readout system for the somatic mutation and recombination test (SMART.

    Directory of Open Access Journals (Sweden)

    Benoit Lombardot

    Full Text Available Genotoxicity testing is an important component of toxicity assessment. As illustrated by the European registration, evaluation, authorization, and restriction of chemicals (REACH directive, it concerns all the chemicals used in industry. The commonly used in vivo mammalian tests appear to be ill adapted to tackle the large compound sets involved, due to throughput, cost, and ethical issues. The somatic mutation and recombination test (SMART represents a more scalable alternative, since it uses Drosophila, which develops faster and requires less infrastructure. Despite these advantages, the manual scoring of the hairs on Drosophila wings required for the SMART limits its usage. To overcome this limitation, we have developed an automated SMART readout. It consists of automated imaging, followed by an image analysis pipeline that measures individual wing genotoxicity scores. Finally, we have developed a wing score-based dose-dependency approach that can provide genotoxicity profiles. We have validated our method using 6 compounds, obtaining profiles almost identical to those obtained from manual measures, even for low-genotoxicity compounds such as urethane. The automated SMART, with its faster and more reliable readout, fulfills the need for a high-throughput in vivo test. The flexible imaging strategy we describe and the analysis tools we provide should facilitate the optimization and dissemination of our methods.

  13. Robotium automated testing for Android

    CERN Document Server

    Zadgaonkar, Hrushikesh

    2013-01-01

    This is a step-by-step, example-oriented tutorial aimed at illustrating the various test scenarios and automation capabilities of Robotium.If you are an Android developer who is learning how to create test cases to test their application, and are looking to get a good grounding in different features in Robotium, this book is ideal for you. It's assumed that you have some experience in Android development, as well be familiar with the Android test framework, as Robotium is a wrapper to Android test framework.

  14. JTst - An Automated Unit Testing Tool for Java Program

    OpenAIRE

    Kamal Z.  Zamli; Nor A. M.  Isa

    2008-01-01

    Software testing is an integral part of software development lifecycle. Lack of testing can often lead to disastrous consequences including lost of data, fortunes, and even lives. Despite its importance, current software testing practice lacks automation, and is still primarily based on highly manual processes from the generation of test cases up to the actual execution of the test. Although the emergence of helpful automated testing tools in the market is blooming, their adoptions are lackin...

  15. Constructing Aligned Assessments Using Automated Test Construction

    Science.gov (United States)

    Porter, Andrew; Polikoff, Morgan S.; Barghaus, Katherine M.; Yang, Rui

    2013-01-01

    We describe an innovative automated test construction algorithm for building aligned achievement tests. By incorporating the algorithm into the test construction process, along with other test construction procedures for building reliable and unbiased assessments, the result is much more valid tests than result from current test construction…

  16. Exploring the Use of a Test Automation Framework

    Science.gov (United States)

    Cervantes, Alex

    2009-01-01

    It is known that software testers, more often than not, lack the time needed to fully test the delivered software product within the time period allotted to them. When problems in the implementation phase of a development project occur, it normally causes the software delivery date to slide. As a result, testers either need to work longer hours, or supplementary resources need to be added to the test team in order to meet aggressive test deadlines. One solution to this problem is to provide testers with a test automation framework to facilitate the development of automated test solutions.

  17. An automated full-symmetry Patterson search method

    International Nuclear Information System (INIS)

    Rius, J.; Miravitlles, C.

    1987-01-01

    A full-symmetry Patterson search method is presented that performs a molecular coarse rotation search in vector space and orientation refinement using the σ function. The oriented molecule is positioned using the fast translation function τ 0 , which is based on the automated interpretation of τ projections using the sum function. This strategy reduces the number of Patterson-function values to be stored in the rotation search, and the use of the τ 0 function minimizes the required time for the development of all probable rotation search solutions. The application of this method to five representative test examples is shown. (orig.)

  18. Galileo battery testing and the impact of test automation

    Science.gov (United States)

    Pertuch, W. T.; Dils, C. T.

    1985-01-01

    Test complexity, changes of test specifications, and the demand for tight control of tests led to the development of automated testing used for Galileo and other projects. The use of standardized interfacing, i.e., IEEE-488, with desktop computers and test instruments, resulted in greater reliability, repeatability, and accuracy of both control and data reporting. Increased flexibility of test programming has reduced costs by permitting a wide spectrum of test requirements at one station rather than many stations.

  19. Automated ECU software tests on hardware-in-the-loop test benches; Automatisierte ECU-Software-Tests an Hardware-in-the-Loop-Pruefstaenden

    Energy Technology Data Exchange (ETDEWEB)

    Voegl, R. [AVL List GmbH, Graz (Austria). Abteilung Kalibrierung Ottomotoren; Duerager, Ch. [AVL List GmbH, Graz (Austria). Abteilung Kalibriermethodik; Beer, W.; Martini, E. [AVL List GmbH, Graz (Austria)

    2005-08-01

    Due to the continuous increase in complexity of engine application, AVL List decided to develop methods for automated ECU software commissioning on HiL test benches. This required the intensive co-operation of the departments for calibration methodology, calibration and electrical/electronic engineering. The result is a practical orientated collection of methods that significantly increase the test coverage for a new software version without extending the commissioning time. (orig.)

  20. Validation of programmable industrial automation systems for safety critical applications in NPP's; dynamic testing

    International Nuclear Information System (INIS)

    Haapanen, P.; Korhonen, J.

    1995-01-01

    The safety assessment of programmable automation systems cannot be totally be based on conventional probabilistic methods because of the difficulties in quantification of the reliability of the software as well as the hardware. Additional means shall therefore be used to gain more confidence on the system dependability. One central confidence building measure is the independent dynamic testing of the completed system. An automated test harness is needed to run the required large amount of test cases in a restricted time span. This paper describes a prototype dynamic testing harness for programmable digital systems developed at VTT. (author). 12 refs, 2 figs, 2 tabs

  1. Automation of Flight Software Regression Testing

    Science.gov (United States)

    Tashakkor, Scott B.

    2016-01-01

    NASA is developing the Space Launch System (SLS) to be a heavy lift launch vehicle supporting human and scientific exploration beyond earth orbit. SLS will have a common core stage, an upper stage, and different permutations of boosters and fairings to perform various crewed or cargo missions. Marshall Space Flight Center (MSFC) is writing the Flight Software (FSW) that will operate the SLS launch vehicle. The FSW is developed in an incremental manner based on "Agile" software techniques. As the FSW is incrementally developed, testing the functionality of the code needs to be performed continually to ensure that the integrity of the software is maintained. Manually testing the functionality on an ever-growing set of requirements and features is not an efficient solution and therefore needs to be done automatically to ensure testing is comprehensive. To support test automation, a framework for a regression test harness has been developed and used on SLS FSW. The test harness provides a modular design approach that can compile or read in the required information specified by the developer of the test. The modularity provides independence between groups of tests and the ability to add and remove tests without disturbing others. This provides the SLS FSW team a time saving feature that is essential to meeting SLS Program technical and programmatic requirements. During development of SLS FSW, this technique has proved to be a useful tool to ensure all requirements have been tested, and that desired functionality is maintained, as changes occur. It also provides a mechanism for developers to check functionality of the code that they have developed. With this system, automation of regression testing is accomplished through a scheduling tool and/or commit hooks. Key advantages of this test harness capability includes execution support for multiple independent test cases, the ability for developers to specify precisely what they are testing and how, the ability to add

  2. Development of the Automated Ultrasonic Testing System for Inspection of the flaw in the Socket Weldment

    International Nuclear Information System (INIS)

    Lee, Jeong Ki; Park, Moon Ho; Park, Ki Sung; Lee, Jae Ho; Lim, Sung Jin

    2004-01-01

    Socket weldment used to change the flow direction of fluid nay have flaws such as lack of fusion and cracks. Liquid penetrant testing or Radiography testing have been applied as NDT methods for flaw detection of the socket weldment. But it is difficult to detect the flaw inside of the socket weldment with these methods. In order to inspect the flaws inside the socket weldment, a ultrasonic testing method is established and a ultrasonic transducer and automated ultrasonic testing system are developed for the inspection. The automated ultrasonic testing system is based on the portable personal computer and operated by the program based Windows 98 or 2000. The system has a pulser/receiver, 100MHz high speed A/D board, and basic functions of ultrasonic flaw detector using the program. For the automated testing, motion controller board of ISA interface type is developed to control the 4-axis scanner and a real time iC-scan image of the automated testing is displayed on the monitor. A flaws with the size of less than 1mm in depth are evaluated smaller than its actual site in the testing, but the flaws larger than 1mm appear larger than its actual size on the contrary. This tendency is shown to be increasing as the flaw size increases. h reliable and objective testing results are obtained with the developed system, so that it is expected that it can contribute to safety management and detection of repair position of pipe lines of nuclear power plants and chemical plants

  3. Comparison of manual and automated pretreatment methods for AMS radiocarbon dating of plant fossils

    Science.gov (United States)

    Bradley, L.A.; Stafford, Thomas W.

    1994-01-01

    A new automated pretreatment system for the preparation of materials submitted for accelerator mass spectrometry (AMS) analysis is less time-consuming and results in a higher sample yield. The new procedure was tested using two groups of plant fossils: one group was pretreated using the traditional method, and the second, using the automated pretreatment apparatus. The time it took to complete the procedure and the amount of sample material remaining were compared. The automated pretreatment apparatus proved to be more than three times faster and, in most cases, produced a higher yield. A darker discoloration of the KOH solutions was observed indicating that the automated system is more thorough in removing humates from the specimen compared to the manual method. -Authors

  4. The SSM/PMAD automated test bed project

    Science.gov (United States)

    Lollar, Louis F.

    1991-01-01

    The Space Station Module/Power Management and Distribution (SSM/PMAD) autonomous subsystem project was initiated in 1984. The project's goal has been to design and develop an autonomous, user-supportive PMAD test bed simulating the SSF Hab/Lab module(s). An eighteen kilowatt SSM/PMAD test bed model with a high degree of automated operation has been developed. This advanced automation test bed contains three expert/knowledge based systems that interact with one another and with other more conventional software residing in up to eight distributed 386-based microcomputers to perform the necessary tasks of real-time and near real-time load scheduling, dynamic load prioritizing, and fault detection, isolation, and recovery (FDIR).

  5. Comparisons of fully automated syphilis tests with conventional VDRL and FTA-ABS tests.

    Science.gov (United States)

    Choi, Seung Jun; Park, Yongjung; Lee, Eun Young; Kim, Sinyoung; Kim, Hyon-Suk

    2013-06-01

    Serologic tests are widely used for the diagnosis of syphilis. However, conventional methods require well-trained technicians to produce reliable results. We compared automated nontreponemal and treponemal tests with conventional methods. The HiSens Auto Rapid Plasma Reagin (AutoRPR) and Treponema Pallidum particle agglutination (AutoTPPA) tests, which utilize latex turbidimetric immunoassay, were assessed. A total of 504 sera were assayed by AutoRPR, AutoTPPA, conventional VDRL and FTA-ABS. Among them, 250 samples were also tested by conventional TPPA. The concordance rate between the results of VDRL and AutoRPR was 67.5%, and 164 discrepant cases were all VDRL reactive but AutoRPR negative. In the 164 cases, 133 showed FTA-ABS reactivity. Medical records of 106 among the 133 cases were reviewed, and 82 among 106 specimens were found to be collected from patients already treated for syphilis. The concordance rate between the results of AutoTPPA and FTA-ABS was 97.8%. The results of conventional TPPA and AutoTPPA for 250 samples were concordant in 241 cases (96.4%). AutoRPR showed higher specificity than that of VDRL, while VDRL demonstrated higher sensitivity than that of AutoRPR regardless of whether the patients had been already treated for syphilis or not. Both FTA-ABS and AutoTPPA showed high sensitivities and specificities greater than 98.0%. Automated RPR and TPPA tests could be alternatives to conventional syphilis tests, and AutoRPR would be particularly suitable in treatment monitoring, since results by AutoRPR in cases after treatment became negative more rapidly than by VDRL. Copyright © 2013. Published by Elsevier Inc.

  6. Generating an Automated Test Suite by Variable Strength Combinatorial Testing for Web Services

    Directory of Open Access Journals (Sweden)

    Yin Li

    2016-09-01

    Full Text Available Testing Web Services has become the spotlight of software engineering as an important means to assure the quality of Web application. Due to lacking of graphic interface and source code, Web services need an automated testing method, which is an important part in efficiently designing and generating test suite. However, the existing testing methods may lead to the redundancy of test suite and the decrease of fault-detecting ability since it cannot handle scenarios where the strengths of the different interactions are not uniform. With the purpose of solving this problem, firstly the formal tree model based on WSDL is constructed and the actual interaction relationship of each node is made sufficient consideration into, then the combinatorial testing is proposed to generate variable strength combinatorial test suite based on One-test-at-a-time strategy. At last test cases are minimized according to constraint rules. The results show that compared with conventional random testing, the proposed approach can detect more errors with the same amount of test cases which turning out to be more ideal than existing ones in size.

  7. Automated Critical Peak Pricing Field Tests: Program Descriptionand Results

    Energy Technology Data Exchange (ETDEWEB)

    Piette, Mary Ann; Watson, David; Motegi, Naoya; Kiliccote, Sila; Xu, Peng

    2006-04-06

    California utilities have been exploring the use of critical peak prices (CPP) to help reduce needle peaks in customer end-use loads. CPP is a form of price-responsive demand response (DR). Recent experience has shown that customers have limited knowledge of how to operate their facilities in order to reduce their electricity costs under CPP (Quantum 2004). While the lack of knowledge about how to develop and implement DR control strategies is a barrier to participation in DR programs like CPP, another barrier is the lack of automation of DR systems. During 2003 and 2004, the PIER Demand Response Research Center (DRRC) conducted a series of tests of fully automated electric demand response (Auto-DR) at 18 facilities. Overall, the average of the site-specific average coincident demand reductions was 8% from a variety of building types and facilities. Many electricity customers have suggested that automation will help them institutionalize their electric demand savings and improve their overall response and DR repeatability. This report focuses on and discusses the specific results of the Automated Critical Peak Pricing (Auto-CPP, a specific type of Auto-DR) tests that took place during 2005, which build on the automated demand response (Auto-DR) research conducted through PIER and the DRRC in 2003 and 2004. The long-term goal of this project is to understand the technical opportunities of automating demand response and to remove technical and market impediments to large-scale implementation of automated demand response (Auto-DR) in buildings and industry. A second goal of this research is to understand and identify best practices for DR strategies and opportunities. The specific objectives of the Automated Critical Peak Pricing test were as follows: (1) Demonstrate how an automated notification system for critical peak pricing can be used in large commercial facilities for demand response (DR). (2) Evaluate effectiveness of such a system. (3) Determine how customers

  8. Validation of programmable industrial automation systems for safety critical applications in NPP's dynamic testing

    International Nuclear Information System (INIS)

    Haapanen, P.; Korhonen, J.

    1995-01-01

    The safety assessment of programmable automation systems can not totally be based on conventional probabilistic methods because of the difficulties in quantification of the reliability of the software as well as the hardware. Additional means shall therefore be used to gain more confidence on the system dependability. One central confidence building measure is the independent dynamic testing of the completed system. An automated test harness is needed to run the required large amount of test cases in a restricted time span. The prototype dynamic testing harness for programmable digital systems developed at the Technical Research Centre of Finland (VTT) is described in the presentation. (12 refs., 2 figs., 2 tabs.)

  9. Evaluation of the PREVI® Isola automated seeder system compared to reference manual inoculation for antibiotic susceptibility testing by the disk diffusion method.

    Science.gov (United States)

    Le Page, S; van Belkum, A; Fulchiron, C; Huguet, R; Raoult, D; Rolain, J-M

    2015-09-01

    The disk diffusion (DD) method remains the most popular manual technique for antibiotic susceptibility testing (AST) in clinical microbiology laboratories. This is because of its simplicity, reproducibility, and limited cost compared to (automated) microdilution systems, which are usually less sensitive at detecting certain important mechanisms of resistance. Here, we evaluate the PREVI® Isola automated seeder system using a new protocol for spreading bacterial suspensions (eight deposits of calibrated inocula of bacteria, followed by two rounds of rotation) in comparison with manual DD reference testing on a large series of clinical and reference strains. The average time required for seeding one agar plate for DD with this new protocol was 51 s per plate, i.e., 70 agar plates/h. Reproducibility and repeatability was assessed on three reference and three randomly chosen clinical strains, as usually requested by the European Committee on Antimicrobial Susceptibility Testing (EUCAST), and was excellent compared to the manual method. The standard deviations of zones of growth inhibition showed no statistical discrimination. The correlation between the two methods, assessed using 294 clinical isolates and a panel of six antibiotics (n = 3,528 zones of growth inhibition measured), was excellent, with a correlation coefficient of 0.977. The new PREVI® Isola protocol adapted for DD had a sensitivity of 99 % and a specificity of 100 % compared to the manual technique for interpreting DD as recommended by the EUCAST.

  10. Start up testing for the secure automated fabrication line

    International Nuclear Information System (INIS)

    Gerber, E.W.; Benson, E.M.; Dahl, R.E.

    1987-01-01

    The secure automated fabrication (SAF) line is a remotely operated, liquid metal reactor fuel fabrication process being built by Westinghouse Hanford Company for the Department of Energy. All process and control equipment is installed and start up testing has been initiated. Start up testing is comprised of five phases, each incorporating higher degrees of equipment integration, automation, and remote control. Testing methodology for SAF line start up is described in this report

  11. Automated Test Requirement Document Generation

    Science.gov (United States)

    1987-11-01

    DIAGNOSTICS BASED ON THE PRINCIPLES OF ARTIFICIAL INTELIGENCE ", 1984 International Test Conference, 01Oct84, (A3, 3, Cs D3, E2, G2, H2, 13, J6, K) 425...j0O GLOSSARY OF ACRONYMS 0 ABBREVIATION DEFINITION AFSATCOM Air Force Satellite Communication Al Artificial Intelligence ASIC Application Specific...In-Test Equipment (BITE) and AI ( Artificial Intelligence) - Expert Systems - need to be fully applied before a completely automated process can be

  12. National Ignition Facility TestController for automated and manual testing

    Energy Technology Data Exchange (ETDEWEB)

    Zielinski, Jason, E-mail: fishler2@llnl.gov [Lawrence Livermore National Laboratory, Livermore, CA 94551 (United States)

    2012-12-15

    The Controls and Information Systems (CIS) organization for the National Ignition Facility (NIF) has developed controls, configuration and analysis software applications that combine for several million lines of code. The team delivers updates throughout the year, from major releases containing hundreds of changes to patch releases containing a small number of focused updates. To ensure the quality of each delivery, manual and automated tests are performed using the NIF TestController test infrastructure. The TestController system provides test inventory management, test planning, automated and manual test execution, release testing summaries and results search, all through a web browser interface. As part of the three-stage software testing strategy, the NIF TestController system helps plan, evaluate and track the readiness of each release to the NIF production environment. After several years of use in testing NIF software applications, the TestController's manual testing features have been leveraged for verifying the installation and operation of NIF Target Diagnostic hardware. The TestController recorded its first test results in 2004. Today, the system has recorded the execution of more than 160,000 tests and continues to play a central role in ensuring that NIF hardware and software meet the requirements of a high reliability facility. This paper describes the TestController system and discusses its use in assuring the quality of software delivered to the NIF.

  13. National Ignition Facility TestController for automated and manual testing

    International Nuclear Information System (INIS)

    Zielinski, Jason

    2012-01-01

    The Controls and Information Systems (CIS) organization for the National Ignition Facility (NIF) has developed controls, configuration and analysis software applications that combine for several million lines of code. The team delivers updates throughout the year, from major releases containing hundreds of changes to patch releases containing a small number of focused updates. To ensure the quality of each delivery, manual and automated tests are performed using the NIF TestController test infrastructure. The TestController system provides test inventory management, test planning, automated and manual test execution, release testing summaries and results search, all through a web browser interface. As part of the three-stage software testing strategy, the NIF TestController system helps plan, evaluate and track the readiness of each release to the NIF production environment. After several years of use in testing NIF software applications, the TestController's manual testing features have been leveraged for verifying the installation and operation of NIF Target Diagnostic hardware. The TestController recorded its first test results in 2004. Today, the system has recorded the execution of more than 160,000 tests and continues to play a central role in ensuring that NIF hardware and software meet the requirements of a high reliability facility. This paper describes the TestController system and discusses its use in assuring the quality of software delivered to the NIF.

  14. Automated Software Testing : A Study of the State of Practice

    OpenAIRE

    Rafi, Dudekula Mohammad; Reddy, Kiran Moses Katam

    2012-01-01

    Context: Software testing is expensive, labor intensive and consumes lot of time in a software development life cycle. There was always a need in software testing to decrease the testing time. This also resulted to focus on Automated Software Testing (AST), because using automated testing, with specific tools, this effort can be dramatically reduced and the costs related with testing can decrease [11]. Manual Testing (MT) requires lot of effort and hard work, if we measure in terms of person ...

  15. The light spot test: Measuring anxiety in mice in an automated home-cage environment.

    Science.gov (United States)

    Aarts, Emmeke; Maroteaux, Gregoire; Loos, Maarten; Koopmans, Bastijn; Kovačević, Jovana; Smit, August B; Verhage, Matthijs; Sluis, Sophie van der

    2015-11-01

    Behavioral tests of animals in a controlled experimental setting provide a valuable tool to advance understanding of genotype-phenotype relations, and to study the effects of genetic and environmental manipulations. To optimally benefit from the increasing numbers of genetically engineered mice, reliable high-throughput methods for comprehensive behavioral phenotyping of mice lines have become a necessity. Here, we describe the development and validation of an anxiety test, the light spot test, that allows for unsupervised, automated, high-throughput testing of mice in a home-cage system. This automated behavioral test circumvents bias introduced by pretest handling, and enables recording both baseline behavior and the behavioral test response over a prolonged period of time. We demonstrate that the light spot test induces a behavioral response in C57BL/6J mice. This behavior reverts to baseline when the aversive stimulus is switched off, and is blunted by treatment with the anxiolytic drug Diazepam, demonstrating predictive validity of the assay, and indicating that the observed behavioral response has a significant anxiety component. Also, we investigated the effectiveness of the light spot test as part of sequential testing for different behavioral aspects in the home-cage. Two learning tests, administered prior to the light spot test, affected the light spot test parameters. The light spot test is a novel, automated assay for anxiety-related high-throughput testing of mice in an automated home-cage environment, allowing for both comprehensive behavioral phenotyping of mice, and rapid screening of pharmacological compounds. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. The development of a Flight Test Engineer's Workstation for the Automated Flight Test Management System

    Science.gov (United States)

    Tartt, David M.; Hewett, Marle D.; Duke, Eugene L.; Cooper, James A.; Brumbaugh, Randal W.

    1989-01-01

    The Automated Flight Test Management System (ATMS) is being developed as part of the NASA Aircraft Automation Program. This program focuses on the application of interdisciplinary state-of-the-art technology in artificial intelligence, control theory, and systems methodology to problems of operating and flight testing high-performance aircraft. The development of a Flight Test Engineer's Workstation (FTEWS) is presented, with a detailed description of the system, technical details, and future planned developments. The goal of the FTEWS is to provide flight test engineers and project officers with an automated computer environment for planning, scheduling, and performing flight test programs. The FTEWS system is an outgrowth of the development of ATMS and is an implementation of a component of ATMS on SUN workstations.

  17. Highly Automated Agile Testing Process: An Industrial Case Study

    Directory of Open Access Journals (Sweden)

    Jarosław Berłowski

    2016-09-01

    Full Text Available This paper presents a description of an agile testing process in a medium size software project that is developed using Scrum. The research methods used is the case study were as follows: surveys, quantifiable project data sources and qualitative project members opinions were used for data collection. Challenges related to the testing process regarding a complex project environment and unscheduled releases were identified. Based on the obtained results, we concluded that the described approach addresses well the aforementioned issues. Therefore, recommendations were made with regard to the employed principles of agility, specifically: continuous integration, responding to change, test automation and test driven development. Furthermore, an efficient testing environment that combines a number of test frameworks (e.g. JUnit, Selenium, Jersey Test with custom-developed simulators is presented.

  18. A semi-automated method for bone age assessment using cervical vertebral maturation.

    Science.gov (United States)

    Baptista, Roberto S; Quaglio, Camila L; Mourad, Laila M E H; Hummel, Anderson D; Caetano, Cesar Augusto C; Ortolani, Cristina Lúcia F; Pisa, Ivan T

    2012-07-01

    To propose a semi-automated method for pattern classification to predict individuals' stage of growth based on morphologic characteristics that are described in the modified cervical vertebral maturation (CVM) method of Baccetti et al. A total of 188 lateral cephalograms were collected, digitized, evaluated manually, and grouped into cervical stages by two expert examiners. Landmarks were located on each image and measured. Three pattern classifiers based on the Naïve Bayes algorithm were built and assessed using a software program. The classifier with the greatest accuracy according to the weighted kappa test was considered best. The classifier showed a weighted kappa coefficient of 0.861 ± 0.020. If an adjacent estimated pre-stage or poststage value was taken to be acceptable, the classifier would show a weighted kappa coefficient of 0.992 ± 0.019. Results from this study show that the proposed semi-automated pattern classification method can help orthodontists identify the stage of CVM. However, additional studies are needed before this semi-automated classification method for CVM assessment can be implemented in clinical practice.

  19. Automated smartphone audiometry: Validation of a word recognition test app.

    Science.gov (United States)

    Dewyer, Nicholas A; Jiradejvong, Patpong; Henderson Sabes, Jennifer; Limb, Charles J

    2018-03-01

    Develop and validate an automated smartphone word recognition test. Cross-sectional case-control diagnostic test comparison. An automated word recognition test was developed as an app for a smartphone with earphones. English-speaking adults with recent audiograms and various levels of hearing loss were recruited from an audiology clinic and were administered the smartphone word recognition test. Word recognition scores determined by the smartphone app and the gold standard speech audiometry test performed by an audiologist were compared. Test scores for 37 ears were analyzed. Word recognition scores determined by the smartphone app and audiologist testing were in agreement, with 86% of the data points within a clinically acceptable margin of error and a linear correlation value between test scores of 0.89. The WordRec automated smartphone app accurately determines word recognition scores. 3b. Laryngoscope, 128:707-712, 2018. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.

  20. Automatic Testing with Formal Methods

    NARCIS (Netherlands)

    Tretmans, G.J.; Belinfante, Axel

    1999-01-01

    The use of formal system specifications makes it possible to automate the derivation of test cases from specifications. This allows to automate the whole testing process, not only the test execution part of it. This paper presents the state of the art and future perspectives in testing based on

  1. Automated testing of health physics instruments

    International Nuclear Information System (INIS)

    Swinth, K.L.; Endres, A.W.; Hadley, R.T.; Kenoyer, J.L.

    1983-12-01

    A microcomputer controlled CAMAC system has been adapted for automated testing of health physics survey instruments. Once the survey instrument is positioned, the system automatically performs tests for angular dependence or battery lifetime. Rotation of the instrument is performed by a computer controlled stepping motor while readout is performed by an auto ranging digital volt meter and data stored on computer disks

  2. Automated Testing with Targeted Event Sequence Generation

    DEFF Research Database (Denmark)

    Jensen, Casper Svenning; Prasad, Mukul R.; Møller, Anders

    2013-01-01

    Automated software testing aims to detect errors by producing test inputs that cover as much of the application source code as possible. Applications for mobile devices are typically event-driven, which raises the challenge of automatically producing event sequences that result in high coverage...

  3. Programmable automated transistor test system

    International Nuclear Information System (INIS)

    Truong, L.V.; Sundberg, G.R.

    1986-01-01

    The paper describes a programmable automated transistor test system (PATTS) and its utilization to evaluate bipolar transistors and Darlingtons, and such MOSFET and special types as can be accommodated with the PATTS base-drive. An application of a pulsed power technique at low duty cycles in a non-destructive test is used to examine the dynamic switching characteristic curves of power transistors. Data collection, manipulation, storage, and output are operator interactive but are guided and controlled by the system software. In addition a library of test data is established on disks, tapes, and hard copies for future reference

  4. Optimization-based Method for Automated Road Network Extraction

    International Nuclear Information System (INIS)

    Xiong, D

    2001-01-01

    Automated road information extraction has significant applicability in transportation. It provides a means for creating, maintaining, and updating transportation network databases that are needed for purposes ranging from traffic management to automated vehicle navigation and guidance. This paper is to review literature on the subject of road extraction and to describe a study of an optimization-based method for automated road network extraction

  5. White matter hyperintensities segmentation: a new semi-automated method

    Directory of Open Access Journals (Sweden)

    Mariangela eIorio

    2013-12-01

    Full Text Available White matter hyperintensities (WMH are brain areas of increased signal on T2-weighted or fluid attenuated inverse recovery magnetic resonance imaging (MRI scans. In this study we present a new semi-automated method to measure WMH load that is based on the segmentation of the intensity histogram of fluid-attenuated inversion recovery images. Thirty patients with Mild Cognitive Impairment with variable WMH load were enrolled. The semi-automated WMH segmentation included: removal of non-brain tissue, spatial normalization, removal of cerebellum and brain stem, spatial filtering, thresholding to segment probable WMH, manual editing for correction of false positives and negatives, generation of WMH map and volumetric estimation of the WMH load. Accuracy was quantitatively evaluated by comparing semi-automated and manual WMH segmentations performed by two independent raters. Differences between the two procedures were assessed using Student’s t tests and similarity was evaluated using linear regression model and Dice Similarity Coefficient (DSC. The volumes of the manual and semi-automated segmentations did not statistically differ (t-value= -1.79, DF=29, p= 0.839 for rater 1; t-value= 1.113, DF=29, p= 0.2749 for rater 2, were highly correlated (R²= 0.921, F (1,29 =155,54, p

  6. A standard analysis method (SAM) for the automated analysis of polychlorinated biphenyls (PCBs) in soils using the chemical analysis automation (CAA) paradigm: validation and performance

    International Nuclear Information System (INIS)

    Rzeszutko, C.; Johnson, C.R.; Monagle, M.; Klatt, L.N.

    1997-10-01

    The Chemical Analysis Automation (CAA) program is developing a standardized modular automation strategy for chemical analysis. In this automation concept, analytical chemistry is performed with modular building blocks that correspond to individual elements of the steps in the analytical process. With a standardized set of behaviors and interactions, these blocks can be assembled in a 'plug and play' manner into a complete analysis system. These building blocks, which are referred to as Standard Laboratory Modules (SLM), interface to a host control system that orchestrates the entire analytical process, from sample preparation through data interpretation. The integrated system is called a Standard Analysis Method (SAME). A SAME for the automated determination of Polychlorinated Biphenyls (PCB) in soils, assembled in a mobile laboratory, is undergoing extensive testing and validation. The SAME consists of the following SLMs: a four channel Soxhlet extractor, a High Volume Concentrator, column clean up, a gas chromatograph, a PCB data interpretation module, a robot, and a human- computer interface. The SAME is configured to meet the requirements specified in U.S. Environmental Protection Agency's (EPA) SW-846 Methods 3541/3620A/8082 for the analysis of pcbs in soils. The PCB SAME will be described along with the developmental test plan. Performance data obtained during developmental testing will also be discussed

  7. Study of geologic-structural situation around Semipalatinsk test site test - holes using space images automated decoding method

    International Nuclear Information System (INIS)

    Gorbunova, Eh.M.; Ivanchenko, G.N.

    2004-01-01

    Performance of underground nuclear explosions (UNE) leads to irreversible changes in geological environment around the boreholes. In natural environment it was detected inhomogeneity of rock massif condition changes, which depended on characteristics of the underground nuclear explosion, anisotropy of medium and presence of faulting. Application of automated selection and statistic analysis of unstretched lineaments in high resolution space images using special software pack LESSA allows specifying the geologic-structural features of Semipalatinsk Test Site (STS), ranging selected fracture zones, outlining and analyzing post-explosion zone surface deformations. (author)

  8. Automated model-based testing of hybrid systems

    NARCIS (Netherlands)

    Osch, van M.P.W.J.

    2009-01-01

    In automated model-based input-output conformance testing, tests are automati- cally generated from a speci¯cation and automatically executed on an implemen- tation. Input is applied to the implementation and output is observed from the implementation. If the observed output is allowed according to

  9. A new automated method of e-learner's satisfaction measurement

    Directory of Open Access Journals (Sweden)

    Armands Strazds

    2007-06-01

    Full Text Available This paper presents a new method of measuring learner’s satisfaction while using electronic learning materials (e-courses, edutainment games, etc. in virtual non-linear environments. Method is based on a relation of Discovering and Learning probability distribution curves obtained by collecting and evaluating the human-computer interaction data. While being near real-time, this measurement is considered highly unobtrusive and cost-effective because of its automated approach. The first working prototype EDUSA 1.0 was developed and successfully tested by the Distance Education Studies Centre of Riga Technical University.

  10. Programmable, automated transistor test system

    Science.gov (United States)

    Truong, L. V.; Sundburg, G. R.

    1986-01-01

    A programmable, automated transistor test system was built to supply experimental data on new and advanced power semiconductors. The data will be used for analytical models and by engineers in designing space and aircraft electric power systems. A pulsed power technique was used at low duty cycles in a nondestructive test to examine the dynamic switching characteristic curves of power transistors in the 500 to 1000 V, 10 to 100 A range. Data collection, manipulation, storage, and output are operator interactive but are guided and controlled by the system software.

  11. Automation Hooks Architecture for Flexible Test Orchestration - Concept Development and Validation

    Science.gov (United States)

    Lansdowne, C. A.; Maclean, John R.; Winton, Chris; McCartney, Pat

    2011-01-01

    The Automation Hooks Architecture Trade Study for Flexible Test Orchestration sought a standardized data-driven alternative to conventional automated test programming interfaces. The study recommended composing the interface using multicast DNS (mDNS/SD) service discovery, Representational State Transfer (Restful) Web Services, and Automatic Test Markup Language (ATML). We describe additional efforts to rapidly mature the Automation Hooks Architecture candidate interface definition by validating it in a broad spectrum of applications. These activities have allowed us to further refine our concepts and provide observations directed toward objectives of economy, scalability, versatility, performance, severability, maintainability, scriptability and others.

  12. Factors That Influence Standard Automated Perimetry Test Results in Glaucoma : Test Reliability, Technician Experience, Time of Day, and Season

    NARCIS (Netherlands)

    Montolio, Francisco G. Junoy; Wesselink, Christiaan; Gordijn, Marijke; Jansonius, Nomdo M.

    2012-01-01

    PURPOSE. To determine the influence of several factors on standard automated perimetry test results in glaucoma. METHODS. Longitudinal Humphrey field analyzer 30-2 Swedish interactive threshold algorithm data from 160 eyes of 160 glaucoma patients were used. The influence of technician experience,

  13. Factors that influence standard automated perimetry test results in glaucoma: Test reliability, technician experience, time of day, and season

    NARCIS (Netherlands)

    F.G.J. Montolio (Francisco G. Junoy); C. Wesselink (Christiaan); M.C.M. Gordijn (Marijke); N.M. Jansonius (Nomdo)

    2012-01-01

    textabstractPURPOSE. To determine the influence of several factors on standard automated perimetry test results in glaucoma. METHODS. Longitudinal Humphrey field analyzer 30-2 Swedish interactive threshold algorithm data from 160 eyes of 160 glaucoma patients were used. The influence of technician

  14. Automated Cross-Sectional Measurement Method of Intracranial Dural Venous Sinuses.

    Science.gov (United States)

    Lublinsky, S; Friedman, A; Kesler, A; Zur, D; Anconina, R; Shelef, I

    2016-03-01

    MRV is an important blood vessel imaging and diagnostic tool for the evaluation of stenosis, occlusions, or aneurysms. However, an accurate image-processing tool for vessel comparison is unavailable. The purpose of this study was to develop and test an automated technique for vessel cross-sectional analysis. An algorithm for vessel cross-sectional analysis was developed that included 7 main steps: 1) image registration, 2) masking, 3) segmentation, 4) skeletonization, 5) cross-sectional planes, 6) clustering, and 7) cross-sectional analysis. Phantom models were used to validate the technique. The method was also tested on a control subject and a patient with idiopathic intracranial hypertension (4 large sinuses tested: right and left transverse sinuses, superior sagittal sinus, and straight sinus). The cross-sectional area and shape measurements were evaluated before and after lumbar puncture in patients with idiopathic intracranial hypertension. The vessel-analysis algorithm had a high degree of stability with <3% of cross-sections manually corrected. All investigated principal cranial blood sinuses had a significant cross-sectional area increase after lumbar puncture (P ≤ .05). The average triangularity of the transverse sinuses was increased, and the mean circularity of the sinuses was decreased by 6% ± 12% after lumbar puncture. Comparison of phantom and real data showed that all computed errors were <1 voxel unit, which confirmed that the method provided a very accurate solution. In this article, we present a novel automated imaging method for cross-sectional vessels analysis. The method can provide an efficient quantitative detection of abnormalities in the dural sinuses. © 2016 by American Journal of Neuroradiology.

  15. [Accuracy, precision and speed of parenteral nutrition admixture bags manufacturing: comparison between automated and manual methods].

    Science.gov (United States)

    Zegbeh, H; Pirot, F; Quessada, T; Durand, T; Vételé, F; Rose, A; Bréant, V; Aulagner, G

    2011-01-01

    The parenteral nutrition admixture (PNA) manufacturing in hospital pharmacy is realized by aseptic transfer (AT) or sterilizing filtration (SF). The development of filling systems for PNA manufacturing requires, without standard, an evaluation comparing to traditional methods of SF. The filling accuracy of automated AT and SF was evaluated by mass and physical-chemistry tests in repeatability conditions (identical composition of PNA; n=five bags) and reproducibility conditions (different composition of PNA; n=57 bags). For each manufacturing method, the filling precision and the average time for PNA bags manufacturing were evaluated starting from an identical composition and volume PNA (n=five trials). Both manufacturing methods did not show significant difference of accuracy. Precision of both methods was lower than limits generally admitted for acceptability of mass and physical-chemistry tests. However, the manufacturing time for SF was superior (five different binary admixtures in five bags) or inferior (one identical binary admixture in five bags) to time recorded for automated AT. We show that serial manufacturing of PNA bags by SF with identical composition is faster than automated AT. Nevertheless, automated AT is faster than SF in variable composition of PNA. The manufacturing method choice will be motivate by the nature (i. e., variable composition or not) of the manufactured bags. Copyright © 2010 Elsevier Masson SAS. All rights reserved.

  16. Doping control in Japan. An automated extraction procedure for the doping test.

    Science.gov (United States)

    Nakajima, T.; Matsumoto, T.

    1976-01-01

    Horse racing in Japan consists of two systems, the National (10 racecourses) and the Regional public racing (32 racecourses) having about 2,500 racing meetings in total per year. Urine or saliva samples for dope testing are collected by the officials from thw winner, second and third, and transported to the laboratory in a frozen state. In 1975, 76, 117 samples were analyzed by this laboratory. The laboratory provides the following four methods of analysis, which are variously combined by request. (1) Method for detection of drugs extracted by chloroform from alkalinized sample. (2) Methods for detection of camphor and its derivatives. (3) Method for detection of barbiturates. (4) Method for detection of ethanol. These methods consist of screening, mainly by thin layer chromatography and confirmatory tests using ultra violet spectrophotometry, gas chromatography and mass spectrometry combined with gas chromatography. In the screening test of doping drugs, alkalinized samples are extracted with chloroform. In order to automate the extraction procedure, the authors contrived a new automatic extractor. They also devised a means of pH adjustment of horse urine by using buffer solution and an efficient mechanism of evaporation of organic solvent. Analytical data obtained by the automatic extractor are presented in this paper. In 1972, we started research work to automate the extraction procedure in method (1) above, and the Automatic Extractor has been in use in routine work since last July. One hundred and twnety samples per hour are extracted automatically by three automatic extractors. The analytical data using this apparatus is presented below. PMID:1000163

  17. Automated Non-Destructive Testing Array Evaluation System

    Energy Technology Data Exchange (ETDEWEB)

    Wei, T.; Zavaljevski, N.; Bakhtiari, S.; Miron, A.; Jupperman, D.

    2004-12-31

    Utilities perform eddy current tests on nuclear power plant steam generator (SG) tubes to detect degradation. This report summarizes the status of ongoing research to develop signal processing algorithms that automate analysis of eddy current test data. The research focuses on analyzing array probe data for detecting, classifying, and characterizing degradation in SG tubes.

  18. Automated Non-Destructive Testing Array Evaluation System

    International Nuclear Information System (INIS)

    Wei, T.; Zavaljevski, N.; Bakhtiari, S.; Miron, A.; Kupperman, D.

    2004-01-01

    Utilities perform eddy current tests on nuclear power plant steam generator (SG) tubes to detect degradation. This report summarizes the status of ongoing research to develop signal processing algorithms that automate analysis of eddy current test data. The research focuses on analyzing array probe data for detecting, classifying, and characterizing degradation in SG tubes

  19. Universal Verification Methodology Based Register Test Automation Flow.

    Science.gov (United States)

    Woo, Jae Hun; Cho, Yong Kwan; Park, Sun Kyu

    2016-05-01

    In today's SoC design, the number of registers has been increased along with complexity of hardware blocks. Register validation is a time-consuming and error-pron task. Therefore, we need an efficient way to perform verification with less effort in shorter time. In this work, we suggest register test automation flow based UVM (Universal Verification Methodology). UVM provides a standard methodology, called a register model, to facilitate stimulus generation and functional checking of registers. However, it is not easy for designers to create register models for their functional blocks or integrate models in test-bench environment because it requires knowledge of SystemVerilog and UVM libraries. For the creation of register models, many commercial tools support a register model generation from register specification described in IP-XACT, but it is time-consuming to describe register specification in IP-XACT format. For easy creation of register model, we propose spreadsheet-based register template which is translated to IP-XACT description, from which register models can be easily generated using commercial tools. On the other hand, we also automate all the steps involved integrating test-bench and generating test-cases, so that designers may use register model without detailed knowledge of UVM or SystemVerilog. This automation flow involves generating and connecting test-bench components (e.g., driver, checker, bus adaptor, etc.) and writing test sequence for each type of register test-case. With the proposed flow, designers can save considerable amount of time to verify functionality of registers.

  20. Server Interface Descriptions for Automated Testing of JavaScript Web Applications

    DEFF Research Database (Denmark)

    Jensen, Casper Svenning; Møller, Anders; Su, Zhendong

    2013-01-01

    Automated testing of JavaScript web applications is complicated by the communication with servers. Specifically, it is difficult to test the JavaScript code in isolation from the server code and database contents. We present a practical solution to this problem. First, we demonstrate that formal...... server interface descriptions are useful in automated testing of JavaScript web applications for separating the concerns of the client and the server. Second, to support the construction of server interface descriptions for existing applications, we introduce an effective inference technique that learns...... communication patterns from sample data. By incorporating interface descriptions into the testing tool Artemis, our experimental results show that we increase the level of automation for high-coverage testing on a collection of JavaScript web applications that exchange JSON data between the clients and servers...

  1. Automation in Immunohematology

    Directory of Open Access Journals (Sweden)

    Meenu Bajpai

    2012-01-01

    Full Text Available There have been rapid technological advances in blood banking in South Asian region over the past decade with an increasing emphasis on quality and safety of blood products. The conventional test tube technique has given way to newer techniques such as column agglutination technique, solid phase red cell adherence assay, and erythrocyte-magnetized technique. These new technologies are adaptable to automation and major manufacturers in this field have come up with semi and fully automated equipments for immunohematology tests in the blood bank. Automation improves the objectivity and reproducibility of tests. It reduces human errors in patient identification and transcription errors. Documentation and traceability of tests, reagents and processes and archiving of results is another major advantage of automation. Shifting from manual methods to automation is a major undertaking for any transfusion service to provide quality patient care with lesser turnaround time for their ever increasing workload. This article discusses the various issues involved in the process.

  2. Automated installation methods for photovoltaic arrays

    Science.gov (United States)

    Briggs, R.; Daniels, A.; Greenaway, R.; Oster, J., Jr.; Racki, D.; Stoeltzing, R.

    1982-11-01

    Since installation expenses constitute a substantial portion of the cost of a large photovoltaic power system, methods for reduction of these costs were investigated. The installation of the photovoltaic arrays includes all areas, starting with site preparation (i.e., trenching, wiring, drainage, foundation installation, lightning protection, grounding and installation of the panel) and concluding with the termination of the bus at the power conditioner building. To identify the optimum combination of standard installation procedures and automated/mechanized techniques, the installation process was investigated including the equipment and hardware available, the photovoltaic array structure systems and interfaces, and the array field and site characteristics. Preliminary designs of hardware for both the standard installation method, the automated/mechanized method, and a mix of standard installation procedures and mechanized procedures were identified to determine which process effectively reduced installation costs. In addition, costs associated with each type of installation method and with the design, development and fabrication of new installation hardware were generated.

  3. 21 CFR 864.9175 - Automated blood grouping and antibody test system.

    Science.gov (United States)

    2010-04-01

    ...) Identification. An automated blood grouping and antibody test system is a device used to group erythrocytes (red blood cells) and to detect antibodies to blood group antigens. (b) Classification. Class II (performance... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Automated blood grouping and antibody test system...

  4. [Automated analyzer of enzyme immunoassay].

    Science.gov (United States)

    Osawa, S

    1995-09-01

    Automated analyzers for enzyme immunoassay can be classified by several points of view: the kind of labeled antibodies or enzymes, detection methods, the number of tests per unit time, analytical time and speed per run. In practice, it is important for us consider the several points such as detection limits, the number of tests per unit time, analytical range, and precision. Most of the automated analyzers on the market can randomly access and measure samples. I will describe the recent advance of automated analyzers reviewing their labeling antibodies and enzymes, the detection methods, the number of test per unit time and analytical time and speed per test.

  5. Prick test: evolution towards automated reading.

    Science.gov (United States)

    Justo, X; Díaz, I; Gil, J J; Gastaminza, G

    2016-08-01

    The prick test is one of the most common medical methods for diagnosing allergies, and it has been carried out in a similar and laborious manner over many decades. In an attempt to standardize the reading of the test, many researchers have tried to automate the process of measuring the allergic reactions found by developing systems and algorithms based on multiple technologies. This work reviews the techniques for automatic wheal measurement with the aim of pointing out their advantages and disadvantages and the progress in the field. Furthermore, it provides a classification scheme for the different technologies applied. The works discussed herein provide evidence that significant challenges still exist for the development of an automatic wheal measurement system that not only helps allergists in their medical practice but also allows for the standardization of the reading and data exchange. As such, the aim of the work was to serve as guideline for the development of a proper and feasible system. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  6. A semi-automated method of monitoring dam passage of American Eels Anguilla rostrata

    Science.gov (United States)

    Welsh, Stuart A.; Aldinger, Joni L.

    2014-01-01

    Fish passage facilities at dams have become an important focus of fishery management in riverine systems. Given the personnel and travel costs associated with physical monitoring programs, automated or semi-automated systems are an attractive alternative for monitoring fish passage facilities. We designed and tested a semi-automated system for eel ladder monitoring at Millville Dam on the lower Shenandoah River, West Virginia. A motion-activated eel ladder camera (ELC) photographed each yellow-phase American Eel Anguilla rostrata that passed through the ladder. Digital images (with date and time stamps) of American Eels allowed for total daily counts and measurements of eel TL using photogrammetric methods with digital imaging software. We compared physical counts of American Eels with camera-based counts; TLs obtained with a measuring board were compared with TLs derived from photogrammetric methods. Data from the ELC were consistent with data obtained by physical methods, thus supporting the semi-automated camera system as a viable option for monitoring American Eel passage. Time stamps on digital images allowed for the documentation of eel passage time—data that were not obtainable from physical monitoring efforts. The ELC has application to eel ladder facilities but can also be used to monitor dam passage of other taxa, such as crayfishes, lampreys, and water snakes.

  7. Automated PCR setup for forensic casework samples using the Normalization Wizard and PCR Setup robotic methods.

    Science.gov (United States)

    Greenspoon, S A; Sykes, K L V; Ban, J D; Pollard, A; Baisden, M; Farr, M; Graham, N; Collins, B L; Green, M M; Christenson, C C

    2006-12-20

    Human genome, pharmaceutical and research laboratories have long enjoyed the application of robotics to performing repetitive laboratory tasks. However, the utilization of robotics in forensic laboratories for processing casework samples is relatively new and poses particular challenges. Since the quantity and quality (a mixture versus a single source sample, the level of degradation, the presence of PCR inhibitors) of the DNA contained within a casework sample is unknown, particular attention must be paid to procedural susceptibility to contamination, as well as DNA yield, especially as it pertains to samples with little biological material. The Virginia Department of Forensic Science (VDFS) has successfully automated forensic casework DNA extraction utilizing the DNA IQ(trade mark) System in conjunction with the Biomek 2000 Automation Workstation. Human DNA quantitation is also performed in a near complete automated fashion utilizing the AluQuant Human DNA Quantitation System and the Biomek 2000 Automation Workstation. Recently, the PCR setup for casework samples has been automated, employing the Biomek 2000 Automation Workstation and Normalization Wizard, Genetic Identity version, which utilizes the quantitation data, imported into the software, to create a customized automated method for DNA dilution, unique to that plate of DNA samples. The PCR Setup software method, used in conjunction with the Normalization Wizard method and written for the Biomek 2000, functions to mix the diluted DNA samples, transfer the PCR master mix, and transfer the diluted DNA samples to PCR amplification tubes. Once the process is complete, the DNA extracts, still on the deck of the robot in PCR amplification strip tubes, are transferred to pre-labeled 1.5 mL tubes for long-term storage using an automated method. The automation of these steps in the process of forensic DNA casework analysis has been accomplished by performing extensive optimization, validation and testing of the

  8. Automated analysis of pumping tests; Analise automatizada de testes de bombeamento

    Energy Technology Data Exchange (ETDEWEB)

    Sugahara, Luiz Alberto Nozaki

    1996-01-01

    An automated procedure for analysis of pumping test data performed in groundwater wells is described. A computer software was developed to be used under the Windows operational system. The software allows the choice of 3 mathematical models for representing the aquifer behavior, which are: Confined aquifer (Theis model); Leaky aquifer (Hantush model); unconfined aquifer (Boulton model). The analysis of pumping test data using the proper aquifer model, allows for the determination of the model parameters such as transmissivity, storage coefficient, leakage coefficient and delay index. The computer program can be used for the analysis of data obtained from both pumping tests, with one or more pumping rates, and recovery tests. In the multiple rate case, a de superposition procedure has been implemented in order to obtain the equivalent aquifer response for the first flow rate, which is used in obtaining an initial estimate of the model parameters. Such initial estimate is required in the non-linear regression analysis method. The solutions to the partial differential equations describing the aquifer behavior were obtained in Laplace space, followed by numerical inversion of the transformed solution using the Stehfest algorithm. The data analysis procedure is based on a non-linear regression method by matching the field data to the theoretical response of a selected aquifer model, for a given type of test. A least squared regression analysis method was implemented using either Gauss-Newton or Levenberg-Marquardt procedures for minimization of a objective function. The computer software can also be applied to multiple rate test data in order to determine the non-linear well coefficient, allowing for the computation of the well inflow performance curve. (author)

  9. Diversity and testing requirements of programmable automation systems

    International Nuclear Information System (INIS)

    Haapanen, P.; Maskuniitty, M.

    1993-04-01

    In the report programmable digital operation and safety automation systems for nuclear power plants are discussed. The programmable systems deviate by their properties and behaviour from the conventional non-programmable systems in such extent, that their verification and validation for safety critical applications requires new methods and practices. The safety assessment can not be based on conventional probabilistic methods due to the difficulties in the quantification of the reliability of the software and hardware. A safety critical programmable system shall include diverse redundant parts so that no residual program fault can not cause the failure of the intended function of the system. Although complete testing of a programmable system is impossible, different tests have a central role in the production and validation process of the system. Diversity is important also in confidence building measures for the implemented system. Independent analysis and testing of the system should use different methods and tools from those used in the production and validation process by the system vendor. Use of diversity and testing are concluded to be central issues in producing safe programmable system and in proving them to be safe enough. By combining functional and programming diversity in a suitable way one can produce a system that is safe enough without having a non-programmable back-up system. (48 refs., 10 figs., 2 tabs.)

  10. Automated real-time testing (ARTT) for embedded control systems (ECS)

    International Nuclear Information System (INIS)

    Hawkins, J; Howard, R; Nguyen, H.

    2001-01-01

    Many of today's automated real-time testing systems for embedded systems were developed using expensive custom hardware and software. In this article they describe how to use commercially available off-the-shelf hardware and software to design and develop an automated real-time test systems for Embedded Programmable Logic Controller (PLC) Based Control Systems. The system development began with the implementation of the VALI/TEST Pro testing methodology as a means for structuring the testing. Using this methodology, they were able to decompose system requirement documents for a Personnel Safety System (PSS) into its high, intermediate and detail level requirements. next, the validation procedures for the PSS system were decomposed into testing units called builds, test runs and test cases. To measure the PSS system's test coverage three levels of system requirements were mapped to their respective unit level of test using a specially constructed validation matrix that was designed to handle over 150 test cases and requirements. All of the above work led to the development of an Automated Real-Time Test System (ARTTS) that is capable of performing complete black box testing in real-time for Embedded PLC Based Control Systems. Also note, that the PSS system under test and mentioned in this paper is located at the Advance Photon Source (APS) at Argonne National Laboratory Basic Energy Science Facility in Argonne, Illinois

  11. Repeatability of an automated Landolt C test, compared with the early treatment of diabetic retinopathy study (ETDRS) chart testing.

    Science.gov (United States)

    Ruamviboonsuk, Paisan; Tiensuwan, Montip; Kunawut, Catleya; Masayaanon, Patcharapim

    2003-10-01

    To evaluate the repeatability of visual acuity scores from the automated test and compare them with the Early Treatment of Diabetic Retinopathy Study (ETDRS) chart. Instrument validation study based on a model of repeatability study in two observations. SMETHODS: a prospective, clinic-based, comparative study. A total of 206 participants without ocular diseases and refractive errors in their right eyes were randomly enrolled in the automated group in which 107 participants performed the automated test and the ETDRS group in which 99 participants read the ETDRS chart. All participants were tested with only their right eyes without corrections at 4 meters and came back to have the same tests 1 week later. The automated test used the Landolt rings as optotypes and was conducted by a low-ended personal computer with a 15-inch monitor and a wireless keyboard. The "letter" score calculated by counting every correct response to optotypes, and the "threshold curve" score interpreted from the optotype size at the midpoint of a visual acuity threshold curve. The 95% confidence interval of test-retest of visual acuity scores from the automated test are comparable to the ETDRS chart (.143 compared with.125 for letter scores,.145 compared with.122 for threshold curve scores). The score repeatabilities, calculated from the standard deviations of test-retest, from the automated test are also comparable to the ETDRS chart (.201 compared with.177 for letter scores,.206 compared with.172 for threshold curve scores). All comparisons demonstrated no statistical difference (P >.05). The automated testing system in this study enables practical measuring visual acuity by the Landolt rings. The system's repeatability, which is comparable to the ETDRS chart, supports its role as an alternative tool for measuring outcome in new clinical research. Its ability to practically generate visual acuity threshold curves may also be useful in future clinical research studies.

  12. Comparing in vitro activity of tigecycline by using the disk diffusion test, the manual microdilution method, and the VITEK 2 automated system.

    Science.gov (United States)

    Leal Castro, A L; Buitrago Gutierrez, G; Ovalle, V; Cortes, J A; Alvarez, C A

    2010-01-01

    Tigecycline is a broad spectrum antibiotic having activity against multiresistant isolates. In vitro susceptibility testing is difficult to perform with the use of traditional microbiological techniques. The aim of this study was to evaluate the disk diffusion test with three different Mueller-Hinton agar brands, and the Vitek 2 automated system in comparison with the standard broth microdilution method against 200 gram-negative isolates (Escherichia coil, Klebsiella pneumoniae, Enterobacter cloacae, Serratia marcescens and Acinetobacter baumannii). Among Enterobacteriaceae, the Becton Dickinson agar had the lowest rate of minor (32.5%) and major errors (3.8%). No very major errors were found. For A. baumanni, the rate of minor and major errors was lower. A high rate of agreement (94%) was found between the broth microdilution method and the Vitek 2 system. Our results show that there are important differences between agars used for the disk diffusion test, and that Vitek 2 is a valid tool for susceptibility testing in clinical laboratories.

  13. Automated detection of test fixture strategies and smells

    NARCIS (Netherlands)

    Greiler, M.S.; Van Deursen, A.; Storey, M.A.

    2013-01-01

    Paper accepted for publication in the Proceedings of the Sixth International Conference on Software Testing, Verification and Validation, IEEE Computer Society, 18-22 March 2013, ISBN 978-1-4673-5961-0, doi: 10.1109/ICST.2013.45 Designing automated tests is a challenging task. One important concern

  14. Factors to Consider When Implementing Automated Software Testing

    Science.gov (United States)

    2016-11-10

    development and integration is a continuous process throughout the acquisition life cycle . Automated Software Testing can improve testing capabilities...requires a lab, conference room, or both, and whether it should be located in- house or an external facility. 2. Ensure space is adequate to support team

  15. 78 FR 27984 - Modification of the National Customs Automation Program Test (NCAP) Regarding Reconciliation for...

    Science.gov (United States)

    2013-05-13

    ... Customs Automation Program Test (NCAP) Regarding Reconciliation for Filing Certain Post-Importation Claims... Automation Program (NCAP) Reconciliation prototype test to include the filing of post-importation [[Page... of the Test Reconciliation, a planned component of the National Customs Automation Program (NCAP), as...

  16. Comparison among single-phase test, automated screening method and GC/MS for the traceability of ketamine in urine

    Directory of Open Access Journals (Sweden)

    Alice Visione

    2016-12-01

    CONCLUSION Following the law indications, ketamine is not searched: this limit does not make the authorities able to apply the penalties expected for road laws violations. The automation is essential to guarantee the reliability of toxicological screening tests, especially to medico-legal significance. This results highlight the absolutely necessity of the execution of the confirmation test, successively to screening analysis.

  17. Automated Execution and Tracking of the LHC Commissioning Tests

    CERN Document Server

    Fuchsberger, K; Galetzka, M; Gorbonosov, R; Pojer, M; Solfaroli Camillocci, M; Zerlauth, M

    2012-01-01

    To ensure the correct operation and prevent system failures, which can lead to equipment damage in the worst case, all critical systems in the Large Hadron Collider (LHC), among them the superconducting circuits, have to be tested thoroughly during dedicated commissioning phases after each intervention. In view of the around 7,000 individual tests to be performed each year after a Christmas stop, a lot of effort was already put into the automation of these tests at the beginning of LHC hardware commissioning in 2005, to assure the dependable execution and analysis of these tests. To further increase the productivity during the commissioning campaigns and to enforce a more consistent workflow, the development of a dedicated testing framework was launched. This new framework is designed to schedule and track the automated tests for all systems of the LHC and will also be extendable, e.g., to beam commissioning tests. This is achieved by re-using different, already existing execution frameworks. In this paper, w...

  18. Automated cloning methods.; TOPICAL

    International Nuclear Information System (INIS)

    Collart, F.

    2001-01-01

    Argonne has developed a series of automated protocols to generate bacterial expression clones by using a robotic system designed to be used in procedures associated with molecular biology. The system provides plate storage, temperature control from 4 to 37 C at various locations, and Biomek and Multimek pipetting stations. The automated system consists of a robot that transports sources from the active station on the automation system. Protocols for the automated generation of bacterial expression clones can be grouped into three categories (Figure 1). Fragment generation protocols are initiated on day one of the expression cloning procedure and encompass those protocols involved in generating purified coding region (PCR)

  19. Automated method of phasing difficult nuclear magnetic resonance spectra with application to the unsaturated carbon analysis of oils

    Energy Technology Data Exchange (ETDEWEB)

    Sterna, L.L.; Tong, V.P. (Shell Development Company, Houston, TX (USA). Westhollow Research Center)

    1991-08-01

    A new method for the automated phasing of n.m.r. spectra is described. The basis of the automation is that the software performs the phasing in the same fashion as a trained n.m.r. operator rather than using mathematical relationships between absorptive and dispersive spectra. The method is illustrated with processing of the {sup 13}C n.m.r. spectrum of a catalytic cracking feedstock. The software readily phased the spectrum even though the spectrum had very broad features and a significant baseline correction. The software performed well even when the time-domain data was left-shifted to introduce a large first-order phase error. The method was applied to measure the percentage of unsaturated carbon in hydrocarbons. Extensive tests were performed to compare automated processing with manual processing for this application; the automated method was found to give both better precision and accuracy. The method can be easily tailored to many other types of analyses. 9 refs., 4 figs., 3 tabs.

  20. Validation of hippocampal volumes measured using a manual method and two automated methods (FreeSurfer and IBASPM) in chronic major depressive disorder

    Energy Technology Data Exchange (ETDEWEB)

    Tae, Woo Suk; Lee, Kang Uk; Nam, Eui-Cheol; Kim, Keun Woo [Kangwon National University College of Medicine, Neuroscience Research Institute, Kangwon (Korea); Kim, Sam Soo [Kangwon National University College of Medicine, Neuroscience Research Institute, Kangwon (Korea); Kangwon National University Hospital, Department of Radiology, Kangwon-do (Korea)

    2008-07-15

    To validate the usefulness of the packages available for automated hippocampal volumetry, we measured hippocampal volumes using one manual and two recently developed automated volumetric methods. The study included T1-weighted magnetic resonance imaging (MRI) of 21 patients with chronic major depressive disorder (MDD) and 20 normal controls. Using coronal turbo field echo (TFE) MRI with a slice thickness of 1.3 mm, the hippocampal volumes were measured using three methods: manual volumetry, surface-based parcellation using FreeSurfer, and individual atlas-based volumetry using IBASPM. In addition, the intracranial cavity volume (ICV) was measured manually. The absolute left hippocampal volume of the patients with MDD measured using all three methods was significantly smaller than the left hippocampal volume of the normal controls (manual P=0.029, FreeSurfer P=0.035, IBASPM P=0.018). After controlling for the ICV, except for the right hippocampal volume measured using FreeSurfer, both measured hippocampal volumes of the patients with MDD were significantly smaller than the measured hippocampal volumes of the normal controls (right manual P=0.019, IBASPM P=0.012; left manual P=0.003, FreeSurfer P=0.010, IBASPM P=0.002). In the intrarater reliability test, the intraclass correlation coefficients (ICCs) were all excellent (manual right 0.947, left 0.934; FreeSurfer right 1.000, left 1.000; IBASPM right 1.000, left 1.000). In the test of agreement between the volumetric methods, the ICCs were right 0.846 and left 0.848 (manual and FreeSurfer), and right 0.654 and left 0.717 (manual and IBASPM). The automated hippocampal volumetric methods showed good agreement with manual hippocampal volumetry, but the volume measured using FreeSurfer was 35% larger and the agreement was questionable with IBASPM. Although the automated methods could detect hippocampal atrophy in the patients with MDD, the results indicate that manual hippocampal volumetry is still the gold standard

  1. Validation of hippocampal volumes measured using a manual method and two automated methods (FreeSurfer and IBASPM) in chronic major depressive disorder

    International Nuclear Information System (INIS)

    Tae, Woo Suk; Lee, Kang Uk; Nam, Eui-Cheol; Kim, Keun Woo; Kim, Sam Soo

    2008-01-01

    To validate the usefulness of the packages available for automated hippocampal volumetry, we measured hippocampal volumes using one manual and two recently developed automated volumetric methods. The study included T1-weighted magnetic resonance imaging (MRI) of 21 patients with chronic major depressive disorder (MDD) and 20 normal controls. Using coronal turbo field echo (TFE) MRI with a slice thickness of 1.3 mm, the hippocampal volumes were measured using three methods: manual volumetry, surface-based parcellation using FreeSurfer, and individual atlas-based volumetry using IBASPM. In addition, the intracranial cavity volume (ICV) was measured manually. The absolute left hippocampal volume of the patients with MDD measured using all three methods was significantly smaller than the left hippocampal volume of the normal controls (manual P=0.029, FreeSurfer P=0.035, IBASPM P=0.018). After controlling for the ICV, except for the right hippocampal volume measured using FreeSurfer, both measured hippocampal volumes of the patients with MDD were significantly smaller than the measured hippocampal volumes of the normal controls (right manual P=0.019, IBASPM P=0.012; left manual P=0.003, FreeSurfer P=0.010, IBASPM P=0.002). In the intrarater reliability test, the intraclass correlation coefficients (ICCs) were all excellent (manual right 0.947, left 0.934; FreeSurfer right 1.000, left 1.000; IBASPM right 1.000, left 1.000). In the test of agreement between the volumetric methods, the ICCs were right 0.846 and left 0.848 (manual and FreeSurfer), and right 0.654 and left 0.717 (manual and IBASPM). The automated hippocampal volumetric methods showed good agreement with manual hippocampal volumetry, but the volume measured using FreeSurfer was 35% larger and the agreement was questionable with IBASPM. Although the automated methods could detect hippocampal atrophy in the patients with MDD, the results indicate that manual hippocampal volumetry is still the gold standard

  2. Automated testing of reactor protection instrumentation made easy

    International Nuclear Information System (INIS)

    Iborra, A.; De Marcos, F.; Pastor, J.A.; Alvarez, B.; Jimenez, A.; Mesa, E.; Alsonso, L.; Regidor, J.J.

    1997-01-01

    Maintenance and testing of reactor protection systems is an important cause of unplanned reactor trips. Automated testing is the answer because it minimises test times and reduces human error. The GAMA I system, developed and implemented at Vandellos II in Spain, has the added advantage that it uses visual programming, which means that changing the software does not need specialist programming skills. (author)

  3. Twelve automated thresholding methods for segmentation of PET images: a phantom study

    International Nuclear Information System (INIS)

    Prieto, Elena; Peñuelas, Iván; Martí-Climent, Josep M; Lecumberri, Pablo; Gómez, Marisol; Pagola, Miguel; Bilbao, Izaskun; Ecay, Margarita

    2012-01-01

    Tumor volume delineation over positron emission tomography (PET) images is of great interest for proper diagnosis and therapy planning. However, standard segmentation techniques (manual or semi-automated) are operator dependent and time consuming while fully automated procedures are cumbersome or require complex mathematical development. The aim of this study was to segment PET images in a fully automated way by implementing a set of 12 automated thresholding algorithms, classical in the fields of optical character recognition, tissue engineering or non-destructive testing images in high-tech structures. Automated thresholding algorithms select a specific threshold for each image without any a priori spatial information of the segmented object or any special calibration of the tomograph, as opposed to usual thresholding methods for PET. Spherical 18 F-filled objects of different volumes were acquired on clinical PET/CT and on a small animal PET scanner, with three different signal-to-background ratios. Images were segmented with 12 automatic thresholding algorithms and results were compared with the standard segmentation reference, a threshold at 42% of the maximum uptake. Ridler and Ramesh thresholding algorithms based on clustering and histogram-shape information, respectively, provided better results that the classical 42%-based threshold (p < 0.05). We have herein demonstrated that fully automated thresholding algorithms can provide better results than classical PET segmentation tools. (paper)

  4. Start up testing for the secure automated fabrication line

    International Nuclear Information System (INIS)

    Gerber, E.W.; Benson, E.M.; Dahl, R.E.

    1986-01-01

    The Secure Automated Fabrication (SAF) Line has been designed and built by Westinghouse Hanford Company for the Department of Energy at the Hanford Site near Richland, Washington. The SAF Line will provide the capability for remote manufacture of fuel for Liquid Metal Reactors, and will supply fuel for the Fast Flux Test Facility (FFTF). The SAF process is highly automated and represents a major advancement in nuclear fuel manufacturing, offering significant improvements in product quality, productivity, safety, and accountability of Special Nuclear Materials. The construction phase of the project is complete, and testing has been initiated to accomplish start up of the plant for manufacture of FFTF fuel. This paper describes the test methodology used for SAF Line start up

  5. Design, Automation, and Test in Europe

    DEFF Research Database (Denmark)

    Systems in CMOS and Beyond; - Physical Design and Validation; - Test and Verification. The winners of the prestigious EDAA Lifetime Achievement Award as well as oher recognized experts in their field wrote an introduction to each section, summarizing the history in their domain and indicating how......The Design, Automation, and Test in Europe (DATE) conference celebrated in 2007 its tenth anniversary. As a tribute to the chip and system-level design and design technology community, this book presents a compilation of the three most influential papers of each year. This provides an excellent...

  6. Development of An Optimization Method for Determining Automation Rate in Nuclear Power Plants

    International Nuclear Information System (INIS)

    Lee, Seung Min; Seong, Poong Hyun; Kim, Jong Hyun

    2014-01-01

    Since automation was introduced in various industrial fields, it has been known that automation provides positive effects like greater efficiency and fewer human errors, and negative effect defined as out-of-the-loop (OOTL). Thus, before introducing automation in nuclear field, the estimation of the positive and negative effects of automation on human operators should be conducted. In this paper, by focusing on CPS, the optimization method to find an appropriate proportion of automation is suggested by integrating the suggested cognitive automation rate and the concepts of the level of ostracism. The cognitive automation rate estimation method was suggested to express the reduced amount of human cognitive loads, and the level of ostracism was suggested to express the difficulty in obtaining information from the automation system and increased uncertainty of human operators' diagnosis. The maximized proportion of automation that maintains the high level of attention for monitoring the situation is derived by an experiment, and the automation rate is estimated by the suggested automation rate estimation method. It is expected to derive an appropriate inclusion proportion of the automation system avoiding the OOTL problem and having maximum efficacy at the same time

  7. Automated Security Testing of Web Widget Interactions

    NARCIS (Netherlands)

    Bezemer, C.P.; Mesbah, A.; Van Deursen, A.

    2009-01-01

    This paper is a pre-print of: Cor-Paul Bezemer, Ali Mesbah, and Arie van Deursen. Automated Security Testing of Web Widget Interactions. In Proceedings of the 7th joint meeting of the European Software Engineering Conference and the ACM SIGSOFT Symposium on the Foundations of Software Engineering

  8. Flexible test automation a software framework for easily developing measurement applications

    CERN Document Server

    Arpaia, Pasquale; De Matteis, Ernesto

    2014-01-01

    In laboratory management of an industrial test division, a test laboratory, or a research center, one of the main activities is producing suitable software for automatic benches by satisfying a given set of requirements. This activity is particularly costly and burdensome when test requirements are variable over time. If the batches of objects have small size and frequent occurrence, the activity of measurement automation becomes predominating with respect to the test execution. Flexible Test Automation shows the development of a software framework as a useful solution to satisfy this exigency. The framework supports the user in producing measurement applications for a wide range of requirements with low effort and development time.

  9. Error response test system and method using test mask variable

    Science.gov (United States)

    Gender, Thomas K. (Inventor)

    2006-01-01

    An error response test system and method with increased functionality and improved performance is provided. The error response test system provides the ability to inject errors into the application under test to test the error response of the application under test in an automated and efficient manner. The error response system injects errors into the application through a test mask variable. The test mask variable is added to the application under test. During normal operation, the test mask variable is set to allow the application under test to operate normally. During testing, the error response test system can change the test mask variable to introduce an error into the application under test. The error response system can then monitor the application under test to determine whether the application has the correct response to the error.

  10. Automation Hooks Architecture Trade Study for Flexible Test Orchestration

    Science.gov (United States)

    Lansdowne, Chatwin A.; Maclean, John R.; Graffagnino, Frank J.; McCartney, Patrick A.

    2010-01-01

    We describe the conclusions of a technology and communities survey supported by concurrent and follow-on proof-of-concept prototyping to evaluate feasibility of defining a durable, versatile, reliable, visible software interface to support strategic modularization of test software development. The objective is that test sets and support software with diverse origins, ages, and abilities can be reliably integrated into test configurations that assemble and tear down and reassemble with scalable complexity in order to conduct both parametric tests and monitored trial runs. The resulting approach is based on integration of three recognized technologies that are currently gaining acceptance within the test industry and when combined provide a simple, open and scalable test orchestration architecture that addresses the objectives of the Automation Hooks task. The technologies are automated discovery using multicast DNS Zero Configuration Networking (zeroconf), commanding and data retrieval using resource-oriented Restful Web Services, and XML data transfer formats based on Automatic Test Markup Language (ATML). This open-source standards-based approach provides direct integration with existing commercial off-the-shelf (COTS) analysis software tools.

  11. A Method for Automated Planning of FTTH Access Network Infrastructures

    DEFF Research Database (Denmark)

    Riaz, Muhammad Tahir; Pedersen, Jens Myrup; Madsen, Ole Brun

    2005-01-01

    In this paper a method for automated planning of Fiber to the Home (FTTH) access networks is proposed. We introduced a systematic approach for planning access network infrastructure. The GIS data and a set of algorithms were employed to make the planning process more automatic. The method explains...... method. The method, however, does not fully automate the planning but make the planning process significantly fast. The results and discussion are presented and conclusion is given in the end....

  12. A fully automated Drosophila olfactory classical conditioning and testing system for behavioral learning and memory assessment.

    Science.gov (United States)

    Jiang, Hui; Hanna, Eriny; Gatto, Cheryl L; Page, Terry L; Bhuva, Bharat; Broadie, Kendal

    2016-03-01

    Aversive olfactory classical conditioning has been the standard method to assess Drosophila learning and memory behavior for decades, yet training and testing are conducted manually under exceedingly labor-intensive conditions. To overcome this severe limitation, a fully automated, inexpensive system has been developed, which allows accurate and efficient Pavlovian associative learning/memory analyses for high-throughput pharmacological and genetic studies. The automated system employs a linear actuator coupled to an odorant T-maze with airflow-mediated transfer of animals between training and testing stages. Odorant, airflow and electrical shock delivery are automatically administered and monitored during training trials. Control software allows operator-input variables to define parameters of Drosophila learning, short-term memory and long-term memory assays. The approach allows accurate learning/memory determinations with operational fail-safes. Automated learning indices (immediately post-training) and memory indices (after 24h) are comparable to traditional manual experiments, while minimizing experimenter involvement. The automated system provides vast improvements over labor-intensive manual approaches with no experimenter involvement required during either training or testing phases. It provides quality control tracking of airflow rates, odorant delivery and electrical shock treatments, and an expanded platform for high-throughput studies of combinational drug tests and genetic screens. The design uses inexpensive hardware and software for a total cost of ∼$500US, making it affordable to a wide range of investigators. This study demonstrates the design, construction and testing of a fully automated Drosophila olfactory classical association apparatus to provide low-labor, high-fidelity, quality-monitored, high-throughput and inexpensive learning and memory behavioral assays. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. An Automated Processing Method for Agglomeration Areas

    Directory of Open Access Journals (Sweden)

    Chengming Li

    2018-05-01

    Full Text Available Agglomeration operations are a core component of the automated generalization of aggregated area groups. However, because geographical elements that possess agglomeration features are relatively scarce, the current literature has not given sufficient attention to agglomeration operations. Furthermore, most reports on the subject are limited to the general conceptual level. Consequently, current agglomeration methods are highly reliant on subjective determinations and cannot support intelligent computer processing. This paper proposes an automated processing method for agglomeration areas. Firstly, the proposed method automatically identifies agglomeration areas based on the width of the striped bridging area, distribution pattern index (DPI, shape similarity index (SSI, and overlap index (OI. Next, the progressive agglomeration operation is carried out, including the computation of the external boundary outlines and the extraction of agglomeration lines. The effectiveness and rationality of the proposed method has been validated by using actual census data of Chinese geographical conditions in the Jiangsu Province.

  14. Establishing a novel automated magnetic bead-based method for the extraction of DNA from a variety of forensic samples.

    Science.gov (United States)

    Witt, Sebastian; Neumann, Jan; Zierdt, Holger; Gébel, Gabriella; Röscheisen, Christiane

    2012-09-01

    Automated systems have been increasingly utilized for DNA extraction by many forensic laboratories to handle growing numbers of forensic casework samples while minimizing the risk of human errors and assuring high reproducibility. The step towards automation however is not easy: The automated extraction method has to be very versatile to reliably prepare high yields of pure genomic DNA from a broad variety of sample types on different carrier materials. To prevent possible cross-contamination of samples or the loss of DNA, the components of the kit have to be designed in a way that allows for the automated handling of the samples with no manual intervention necessary. DNA extraction using paramagnetic particles coated with a DNA-binding surface is predestined for an automated approach. For this study, we tested different DNA extraction kits using DNA-binding paramagnetic particles with regard to DNA yield and handling by a Freedom EVO(®)150 extraction robot (Tecan) equipped with a Te-MagS magnetic separator. Among others, the extraction kits tested were the ChargeSwitch(®)Forensic DNA Purification Kit (Invitrogen), the PrepFiler™Automated Forensic DNA Extraction Kit (Applied Biosystems) and NucleoMag™96 Trace (Macherey-Nagel). After an extensive test phase, we established a novel magnetic bead extraction method based upon the NucleoMag™ extraction kit (Macherey-Nagel). The new method is readily automatable and produces high yields of DNA from different sample types (blood, saliva, sperm, contact stains) on various substrates (filter paper, swabs, cigarette butts) with no evidence of a loss of magnetic beads or sample cross-contamination. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  15. Comparison of manual and automated quantification methods of 123I-ADAM

    International Nuclear Information System (INIS)

    Kauppinen, T.; Keski-Rahkonen, A.; Sihvola, E.; Helsinki Univ. Central Hospital

    2005-01-01

    123 I-ADAM is a novel radioligand for imaging of the brain serotonin transporters (SERTs). Traditionally, the analysis of brain receptor studies has been based on observer-dependent manual region of interest definitions and visual interpretation. Our aim was to create a template for automated image registrations and volume of interest (VOI) quantification and to show that an automated quantification method of 123 I-ADAM is more repeatable than the manual method. Patients, methods: A template and a predefined VOI map was created from 123 I-ADAM scans done for healthy volunteers (n=15). Scans of another group of healthy persons (HS, n=12) and patients with bulimia nervosa (BN, n=10) were automatically fitted to the template and specific binding ratios (SBRs) were calculated by using the VOI map. Manual VOI definitions were done for the HS and BN groups by both one and two observers. The repeatability of the automated method was evaluated by using the BN group. Results: For the manual method, the interobserver coefficient of repeatability was 0.61 for the HS group and 1.00 for the BN group. The intra-observer coefficient of repeatability for the BN group was 0.70. For the automated method, the coefficient of repeatability was 0.13 for SBRs in midbrain. Conclusion: An automated quantification gives valuable information in addition to visual interpretation decreasing also the total image handling time and giving clear advantages for research work. An automated method for analysing 123 I-ADAM binding to the brain SERT gives repeatable results for fitting the studies to the template and for calculating SBRs, and could therefore replace manual methods. (orig.)

  16. A Framework for Automated Testing of JavaScript Web Applications

    DEFF Research Database (Denmark)

    Artzi, Shay; Dolby, Julian; Jensen, Simon Holm

    2011-01-01

    Current practice in testing JavaScript web applications requires manual construction of test cases, which is difficult and tedious. We present a framework for feedback-directed automated test generation for JavaScript in which execution is monitored to collect information that directs the test...

  17. Development of an Automated LIBS Analytical Test System Integrated with Component Control and Spectrum Analysis Capabilities

    International Nuclear Information System (INIS)

    Ding Yu; Tian Di; Chen Feipeng; Chen Pengfei; Qiao Shujun; Yang Guang; Li Chunsheng

    2015-01-01

    The present paper proposes an automated Laser-Induced Breakdown Spectroscopy (LIBS) analytical test system, which consists of a LIBS measurement and control platform based on a modular design concept, and a LIBS qualitative spectrum analysis software and is developed in C#. The platform provides flexible interfacing and automated control; it is compatible with different manufacturer component models and is constructed in modularized form for easy expandability. During peak identification, a more robust peak identification method with improved stability in peak identification has been achieved by applying additional smoothing on the slope obtained by calculation before peak identification. For the purpose of element identification, an improved main lines analysis method, which detects all elements on the spectral peak to avoid omission of certain elements without strong spectral lines, is applied to element identification in the tested LIBS samples. This method also increases the identification speed. In this paper, actual applications have been carried out. According to tests, the analytical test system is compatible with components of various models made by different manufacturers. It can automatically control components to get experimental data and conduct filtering, peak identification and qualitative analysis, etc. on spectral data. (paper)

  18. Development testing of the chemical analysis automation polychlorinated biphenyl standard analysis method during surface soils sampling at the David Witherspoon 1630 site

    International Nuclear Information System (INIS)

    Hunt, M.A.; Klatt, L.N.; Thompson, D.H.

    1998-02-01

    The Chemical Analysis Automation (CAA) project is developing standardized, software-driven, site-deployable robotic laboratory systems with the objective of lowering the per-sample analysis cost, decreasing sample turnaround time, and minimizing human exposure to hazardous and radioactive materials associated with DOE remediation projects. The first integrated system developed by the CAA project is designed to determine polychlorinated biphenyls (PCB) content in soil matrices. A demonstration and development testing of this system was conducted in conjuction with surface soil characterization activities at the David Witherspoon 1630 Site in Knoxville, Tennessee. The PCB system consists of five hardware standard laboratory modules (SLMs), one software SLM, the task sequence controller (TSC), and the human-computer interface (HCI). Four of the hardware SLMs included a four-channel Soxhlet extractor, a high-volume concentrator, a column cleanup, and a gas chromatograph. These SLMs performed the sample preparation and measurement steps within the total analysis protocol. The fifth hardware module was a robot that transports samples between the SLMs and the required consumable supplies to the SLMs. The software SLM is an automated data interpretation module that receives raw data from the gas chromatograph SLM and analyzes the data to yield the analyte information. The TSC is a software system that provides the scheduling, management of system resources, and the coordination of all SLM activities. The HCI is a graphical user interface that presents the automated laboratory to the analyst in terms of the analytical procedures and methods. Human control of the automated laboratory is accomplished via the HCI. Sample information required for processing by the automated laboratory is entered through the HCI. Information related to the sample and the system status is presented to the analyst via graphical icons

  19. Spaceport Command and Control System Automation Testing

    Science.gov (United States)

    Plano, Tom

    2017-01-01

    The goal of automated testing is to create and maintain a cohesive infrastructure of robust tests that could be run independently on a software package in its entirety. To that end, the Spaceport Command and Control System (SCCS) project at the National Aeronautics and Space Administration's (NASA) Kennedy Space Center (KSC) has brought in a large group of interns to work side-by-side with full time employees to do just this work. Thus, our job is to implement the tests that will put SCCS through its paces.

  20. Automated reactor protection testing saves time and avoids errors

    International Nuclear Information System (INIS)

    Raimondo, E.

    1990-01-01

    When the Pressurized Water Reactor units in the French 900MWe series were designed, the instrumentation and control systems were equipped for manual periodic testing. Manual reactor protection system testing has since been successfully replaced by an automatic system, which is also applicable to other instrumentation testing. A study on the complete automation of process instrumentation testing has been carried out. (author)

  1. A Case Study Improvement of a Testing Process by Combining Lean Management, Industrial Engineering and Automation Methods

    Directory of Open Access Journals (Sweden)

    Simon Withers

    2013-07-01

    Full Text Available Increasingly competitive market environments have forced not only large manufacturing, but also smalland-medium size enterprises (SME to look for means to improve their operations in order to increase competitive strength. This paper presents an adaptation and adoption by a UK SME engineering service organisation, of lean management, industrial engineering, and automation metods developed within larger organisations. This SME sought to improve the overall performance of one of its core testing processes. An exploratory analysis, based on the lean management concept of “value added” and work measurement technique “time study”, was developed and carried out in order to understand the current performance of a testing process for gas turbine fuel flow dividers. A design for the automation of some operations of the testing process was followed as an approach to reduce non-value added activities, and improve the overall efficiency of the testing process. The overall testing time was reduced from 12.41 to 7.93 hours (36.09 percent while the man hours and non-value added time were also reduced from 23.91 to 12.94 hours (45.87 percent and from 11.08 to 6.69 (39.67 percent hours respectively. This resulted in an increase in process efficiency in terms of man hours from 51.91 to 61.28 percent. The contribution of this paper resides in presenting a case study that can be used as a guiding reference for managers and engineers to undertake improvement projects, in their organisations, similar to the one presented in this paper.

  2. Babcock experience of automated ultrasonic non-destructive testing of PWR pressure vessels during manufacture

    International Nuclear Information System (INIS)

    Dikstra, B.J.; Farley, J.M.; Scruton, G.

    1990-01-01

    Major developments in ultrasonic techniques, equipment and systems for automated inspection have lead, over a period of about ten years, to the regular application of sophisticated computer-controlled systems during the manufacture of nuclear reactor pressure vessels. Ten years ago the use of procedures defined in a code such as ASME XI might have been considered sufficient, but it is now necessary, as was demonstrated by the results of the UKAEA defect detection trials and the PISC II trials, to apply more comprehensive arrays of probes and higher test sensitivities. The ultrasonic techniques selected are demonstrated to be adequate by modelling or test-block exercises, the automated systems applied are subject to stringent quality assurance testing, and very rigorous inspection procedures are used in conjunction with a high degree of automation to ensure reproducibility of inspection quality. The state-of-the-art in automated ultrasonic testing of pressure vessels by Babcock is described. Current developments by the company, including automated flaw recognition, integrated modelling of inspection capability, and the use of electronically scanned variable-angle probes are reviewed. Examples quoted include the automated ultrasonic inspections of the Sizewell B pressurized water reactor vessel. (author)

  3. Automation of ultrasonic testing of turbine disk billets

    International Nuclear Information System (INIS)

    Gorodkov, V.E.; Domashevskij, B.N.; Pron', N.I.; Tkachenko, V.A.

    1984-01-01

    cations of ultrasonic facility for automation of testing turbine disk billets of 25Kh2PMFA and 34KhM1A steels are considered. The operating principle and the design of ''Disk-1'' facility are described, its test results are presented. It is shown that the facility increases the test efficiency five times, enables to estimate dimensions of revealed defect with regard to the quality of acoustic contact, thus facilitating the work of personnel and improving the test quality

  4. Completely automated modal analysis procedure based on the combination of different OMA methods

    Science.gov (United States)

    Ripamonti, Francesco; Bussini, Alberto; Resta, Ferruccio

    2018-03-01

    In this work a completely automated output-only Modal Analysis procedure is presented and all its benefits are listed. Based on the merging of different Operational Modal Analysis methods and a statistical approach, the identification process has been improved becoming more robust and giving as results only the real natural frequencies, damping ratios and mode shapes of the system. The effect of the temperature can be taken into account as well, leading to the creation of a better tool for automated Structural Health Monitoring. The algorithm has been developed and tested on a numerical model of a scaled three-story steel building present in the laboratories of Politecnico di Milano.

  5. Formal Test Automation: The Conference protocol with TGV/TorX

    NARCIS (Netherlands)

    Ural, Hasan; Du Bousquet, Lydie; Ramangalahy, Solofo; Probert, Robert L.; von Bochmann, Gregor; Simon, Severine; Viho, Cesar; Belinfante, Axel; de Vries, R.G.

    We present an experiment of automated formal conformance testing of the Conference Protocol Entity as reported in [2]. Our approach differs from other experiments, since it investigates the combination of the tools TGV for abstract test generation and TorX for test execution.

  6. A novel automated rat catalepsy bar test system based on a RISC microcontroller.

    Science.gov (United States)

    Alvarez-Cervera, Fernando J; Villanueva-Toledo, Jairo; Moo-Puc, Rosa E; Heredia-López, Francisco J; Alvarez-Cervera, Margarita; Pineda, Juan C; Góngora-Alfaro, José L

    2005-07-15

    Catalepsy tests performed in rodents treated with drugs that interfere with dopaminergic transmission have been widely used for the screening of drugs with therapeutic potential in the treatment of Parkinson's disease. The basic method for measuring catalepsy intensity is the "standard" bar test. We present here an easy to use microcontroller-based automatic system for recording bar test experiments. The design is simple, compact, and has a low cost. Recording intervals and total experimental time can be programmed within a wide range of values. The resulting catalepsy times are stored, and up to five simultaneous experiments can be recorded. A standard personal computer interface is included. The automated system also permits the elimination of human error associated with factors such as fatigue, distraction, and data transcription, occurring during manual recording. Furthermore, a uniform criterion for timing the cataleptic condition can be achieved. Correlation values between the results obtained with the automated system and those reported by two independent observers ranged between 0.88 and 0.99 (P<0.0001; three treatments, nine animals, 144 catalepsy time measurements).

  7. A Systematic, Automated Network Planning Method

    DEFF Research Database (Denmark)

    Holm, Jens Åge; Pedersen, Jens Myrup

    2006-01-01

    This paper describes a case study conducted to evaluate the viability of a systematic, automated network planning method. The motivation for developing the network planning method was that many data networks are planned in an adhoc manner with no assurance of quality of the solution with respect...... structures, that are ready to implement in a real world scenario, are discussed in the end of the paper. These are in the area of ensuring line independence and complexity of the design rules for the planning method....

  8. SU-E-CAMPUS-T-01: Automation of the Winston-Lutz Test for Stereotactic Radiosurgery

    Energy Technology Data Exchange (ETDEWEB)

    Litzenberg, D; Irrer, J; Kessler, M; Lam, K [University of Michigan, Ann Arbor, MI (United States); Keranen, W [Varian Medical Systems, Inc., Palo Alto, CA (United States)

    2014-06-15

    Purpose: To optimize clinical efficiency and shorten patient wait time by minimizing the time and effort required to perform the Winston-Lutz test before stereotactic radiosurgery (SRS) through automation of the delivery, analysis, and documentation of results. Methods: The radiation fields of the Winston-Lutz (WL) test were created in a “machine-QA patient” saved in ARIA for use before SRS cases. Images of the BRW target ball placed at mechanical isocenter are captured with the portal imager for each of four, 2cm×2cm, MLC-shaped beams. When the WL plan is delivered and closed, this event is detected by in-house software called EventNet which automates subsequent processes with the aid of the ARIA web services. Images are automatically retrieved from the ARIA database and analyzed to determine the offset of the target ball from radiation isocenter. The results are posted to a website and a composite summary image of the results is pushed back into ImageBrowser for review and authenticated documentation. Results: The total time to perform the test was reduced from 20-25 minutes to less than 4 minutes. The results were found to be more accurate and consistent than the previous method which used radiochromic film. The images were also analyzed with DoseLab for comparison. The difference between the film and automated WL results in the X and Y direction and the radius were (−0.17 +/− 0.28) mm, (0.21 +/− 0.20) mm and (−0.14 +/− 0.27) mm, respectively. The difference between the DoseLab and automated WL results were (−0.05 +/− 0.06) mm, (−0.01 +/− 0.02) mm and (0.01 +/− 0.07) mm, respectively. Conclusions: This process reduced patient wait times by 15–20 minutes making the treatment machine available to treat another patient. Accuracy and consistency of results were improved over the previous method and were comparable to other commercial solutions. Access to the ARIA web services is made possible through an Eclipse co-development agreement

  9. Automated Vision Test Development and Validation

    Science.gov (United States)

    2016-11-01

    crystal display monitor (NEC Multisync, P232W) at 1920x1080 resolution. Proper calibration was confirmed using a spot photometer/colorimeter (X-Rite i1...visual input to the right and left eye was achieved using liquid crystal display shuttered glasses (NVIDIA 3D Vision 2). The stereo target (Figure 4...threshold on the automated tasks. • Subjects had a lower (better) threshold on color testing for all cone types using the OCCT due to a ceiling

  10. Automated testing of electro-optical systems; Proceedings of the Meeting, Orlando, FL, Apr. 7, 8, 1988

    International Nuclear Information System (INIS)

    Nestler, J.; Richardson, P.I.

    1988-01-01

    Various papers on the automated testing of electrooptical systems are presented. Individual topics addressed include: simultaneous automated testing of Thematic Mapper dynamic spatial performance characteristics, results of objective automatic minimum resolvable temperature testing of thermal imagers using a proposed new figure of merit, test and manufacture of three-mirror laboratory telescope, calculation of apparent delta-T errors for band-limited detectors, and automated laser seeker performance evaluation system

  11. Comparison of manual and automated quantification methods of {sup 123}I-ADAM

    Energy Technology Data Exchange (ETDEWEB)

    Kauppinen, T. [Helsinki Univ. Central Hospital (Finland). HUS Helsinki Medical Imaging Center; Helsinki Univ. Central Hospital (Finland). Division of Nuclear Medicine; Koskela, A.; Ahonen, A. [Helsinki Univ. Central Hospital (Finland). Division of Nuclear Medicine; Diemling, M. [Hermes Medical Solutions, Stockholm (Sweden); Keski-Rahkonen, A.; Sihvola, E. [Helsinki Univ. (Finland). Dept. of Public Health; Helsinki Univ. Central Hospital (Finland). Dept. of Psychiatry

    2005-07-01

    {sup 123}I-ADAM is a novel radioligand for imaging of the brain serotonin transporters (SERTs). Traditionally, the analysis of brain receptor studies has been based on observer-dependent manual region of interest definitions and visual interpretation. Our aim was to create a template for automated image registrations and volume of interest (VOI) quantification and to show that an automated quantification method of {sup 123}I-ADAM is more repeatable than the manual method. Patients, methods: A template and a predefined VOI map was created from {sup 123}I-ADAM scans done for healthy volunteers (n=15). Scans of another group of healthy persons (HS, n=12) and patients with bulimia nervosa (BN, n=10) were automatically fitted to the template and specific binding ratios (SBRs) were calculated by using the VOI map. Manual VOI definitions were done for the HS and BN groups by both one and two observers. The repeatability of the automated method was evaluated by using the BN group. Results: For the manual method, the interobserver coefficient of repeatability was 0.61 for the HS group and 1.00 for the BN group. The intra-observer coefficient of repeatability for the BN group was 0.70. For the automated method, the coefficient of repeatability was 0.13 for SBRs in midbrain. Conclusion: An automated quantification gives valuable information in addition to visual interpretation decreasing also the total image handling time and giving clear advantages for research work. An automated method for analysing {sup 123}I-ADAM binding to the brain SERT gives repeatable results for fitting the studies to the template and for calculating SBRs, and could therefore replace manual methods. (orig.)

  12. Improving automated 3D reconstruction methods via vision metrology

    Science.gov (United States)

    Toschi, Isabella; Nocerino, Erica; Hess, Mona; Menna, Fabio; Sargeant, Ben; MacDonald, Lindsay; Remondino, Fabio; Robson, Stuart

    2015-05-01

    This paper aims to provide a procedure for improving automated 3D reconstruction methods via vision metrology. The 3D reconstruction problem is generally addressed using two different approaches. On the one hand, vision metrology (VM) systems try to accurately derive 3D coordinates of few sparse object points for industrial measurement and inspection applications; on the other, recent dense image matching (DIM) algorithms are designed to produce dense point clouds for surface representations and analyses. This paper strives to demonstrate a step towards narrowing the gap between traditional VM and DIM approaches. Efforts are therefore intended to (i) test the metric performance of the automated photogrammetric 3D reconstruction procedure, (ii) enhance the accuracy of the final results and (iii) obtain statistical indicators of the quality achieved in the orientation step. VM tools are exploited to integrate their main functionalities (centroid measurement, photogrammetric network adjustment, precision assessment, etc.) into the pipeline of 3D dense reconstruction. Finally, geometric analyses and accuracy evaluations are performed on the raw output of the matching (i.e. the point clouds) by adopting a metrological approach. The latter is based on the use of known geometric shapes and quality parameters derived from VDI/VDE guidelines. Tests are carried out by imaging the calibrated Portable Metric Test Object, designed and built at University College London (UCL), UK. It allows assessment of the performance of the image orientation and matching procedures within a typical industrial scenario, characterised by poor texture and known 3D/2D shapes.

  13. A Novel Tool for High-Throughput Screening of Granulocyte-Specific Antibodies Using the Automated Flow Cytometric Granulocyte Immunofluorescence Test (Flow-GIFT

    Directory of Open Access Journals (Sweden)

    Xuan Duc Nguyen

    2011-01-01

    Full Text Available Transfusion-related acute lung injury (TRALI is a severe complication related with blood transfusion. TRALI has usually been associated with antibodies against leukocytes. The flow cytometric granulocyte immunofluorescence test (Flow-GIFT has been introduced for routine use when investigating patients and healthy blood donors. Here we describe a novel tool in the automation of the Flow-GIFT that enables a rapid screening of blood donations. We analyzed 440 sera from healthy female blood donors for the presence of granulocyte antibodies. As positive controls, 12 sera with known antibodies against anti-HNA-1a, -b, -2a; and -3a were additionally investigated. Whole-blood samples from HNA-typed donors were collected and the test cells isolated using cell sedimentation in a Ficoll density gradient. Subsequently, leukocytes were incubated with the respective serum and binding of antibodies was detected using FITC-conjugated antihuman antibody. 7-AAD was used to exclude dead cells. Pipetting steps were automated using the Biomek NXp Multichannel Automation Workstation. All samples were prepared in the 96-deep well plates and analyzed by flow cytometry. The standard granulocyte immunofluorescence test (GIFT and granulocyte agglutination test (GAT were also performed as reference methods. Sixteen sera were positive in the automated Flow-GIFT, while five of these sera were negative in the standard GIFT (anti—HNA 3a, n = 3; anti—HNA-1b, n = 1 and GAT (anti—HNA-2a, n = 1. The automated Flow-GIFT was able to detect all granulocyte antibodies, which could be only detected in GIFT in combination with GAT. In serial dilution tests, the automated Flow-GIFT detected the antibodies at higher dilutions than the reference methods GIFT and GAT. The Flow-GIFT proved to be feasible for automation. This novel high-throughput system allows an effective antigranulocyte antibody detection in a large donor population in order to prevent TRALI due to transfusion of

  14. A novel tool for high-throughput screening of granulocyte-specific antibodies using the automated flow cytometric granulocyte immunofluorescence test (Flow-GIFT).

    Science.gov (United States)

    Nguyen, Xuan Duc; Dengler, Thomas; Schulz-Linkholt, Monika; Klüter, Harald

    2011-02-03

    Transfusion-related acute lung injury (TRALI) is a severe complication related with blood transfusion. TRALI has usually been associated with antibodies against leukocytes. The flow cytometric granulocyte immunofluorescence test (Flow-GIFT) has been introduced for routine use when investigating patients and healthy blood donors. Here we describe a novel tool in the automation of the Flow-GIFT that enables a rapid screening of blood donations. We analyzed 440 sera from healthy female blood donors for the presence of granulocyte antibodies. As positive controls, 12 sera with known antibodies against anti-HNA-1a, -b, -2a; and -3a were additionally investigated. Whole-blood samples from HNA-typed donors were collected and the test cells isolated using cell sedimentation in a Ficoll density gradient. Subsequently, leukocytes were incubated with the respective serum and binding of antibodies was detected using FITC-conjugated antihuman antibody. 7-AAD was used to exclude dead cells. Pipetting steps were automated using the Biomek NXp Multichannel Automation Workstation. All samples were prepared in the 96-deep well plates and analyzed by flow cytometry. The standard granulocyte immunofluorescence test (GIFT) and granulocyte agglutination test (GAT) were also performed as reference methods. Sixteen sera were positive in the automated Flow-GIFT, while five of these sera were negative in the standard GIFT (anti-HNA 3a, n = 3; anti-HNA-1b, n = 1) and GAT (anti-HNA-2a, n = 1). The automated Flow-GIFT was able to detect all granulocyte antibodies, which could be only detected in GIFT in combination with GAT. In serial dilution tests, the automated Flow-GIFT detected the antibodies at higher dilutions than the reference methods GIFT and GAT. The Flow-GIFT proved to be feasible for automation. This novel high-throughput system allows an effective antigranulocyte antibody detection in a large donor population in order to prevent TRALI due to transfusion of blood products.

  15. A multi-atlas based method for automated anatomical rat brain MRI segmentation and extraction of PET activity.

    Science.gov (United States)

    Lancelot, Sophie; Roche, Roxane; Slimen, Afifa; Bouillot, Caroline; Levigoureux, Elise; Langlois, Jean-Baptiste; Zimmer, Luc; Costes, Nicolas

    2014-01-01

    Preclinical in vivo imaging requires precise and reproducible delineation of brain structures. Manual segmentation is time consuming and operator dependent. Automated segmentation as usually performed via single atlas registration fails to account for anatomo-physiological variability. We present, evaluate, and make available a multi-atlas approach for automatically segmenting rat brain MRI and extracting PET activies. High-resolution 7T 2DT2 MR images of 12 Sprague-Dawley rat brains were manually segmented into 27-VOI label volumes using detailed protocols. Automated methods were developed with 7/12 atlas datasets, i.e. the MRIs and their associated label volumes. MRIs were registered to a common space, where an MRI template and a maximum probability atlas were created. Three automated methods were tested: 1/registering individual MRIs to the template, and using a single atlas (SA), 2/using the maximum probability atlas (MP), and 3/registering the MRIs from the multi-atlas dataset to an individual MRI, propagating the label volumes and fusing them in individual MRI space (propagation & fusion, PF). Evaluation was performed on the five remaining rats which additionally underwent [18F]FDG PET. Automated and manual segmentations were compared for morphometric performance (assessed by comparing volume bias and Dice overlap index) and functional performance (evaluated by comparing extracted PET measures). Only the SA method showed volume bias. Dice indices were significantly different between methods (PF>MP>SA). PET regional measures were more accurate with multi-atlas methods than with SA method. Multi-atlas methods outperform SA for automated anatomical brain segmentation and PET measure's extraction. They perform comparably to manual segmentation for FDG-PET quantification. Multi-atlas methods are suitable for rapid reproducible VOI analyses.

  16. A review on automated pavement distress detection methods

    NARCIS (Netherlands)

    Coenen, Tom B.J.; Golroo, Amir

    2017-01-01

    In recent years, extensive research has been conducted on pavement distress detection. A large part of these studies applied automated methods to capture different distresses. In this paper, a literature review on the distresses and related detection methods are presented. This review also includes

  17. Automated migration analysis based on cell texture: method & reliability

    Directory of Open Access Journals (Sweden)

    Chittenden Thomas W

    2005-03-01

    Full Text Available Abstract Background In this paper, we present and validate a way to measure automatically the extent of cell migration based on automated examination of a series of digital photographs. It was designed specifically to identify the impact of Second Hand Smoke (SHS on endothelial cell migration but has broader applications. The analysis has two stages: (1 preprocessing of image texture, and (2 migration analysis. Results The output is a graphic overlay that indicates the front lines of cell migration superimposed on each original image, with automated reporting of the distance traversed vs. time. Expert preference compares to manual placement of leading edge shows complete equivalence of automated vs. manual leading edge definition for cell migration measurement. Conclusion Our method is indistinguishable from careful manual determinations of cell front lines, with the advantages of full automation, objectivity, and speed.

  18. METHODOLOGICAL PROBLEMS AND WAYS OF CREATION OF THE AIRCRAFT EQUIPMENT TEST AUTOMATED MANAGEMENT SYSTEM

    Directory of Open Access Journals (Sweden)

    Vladimir Michailovich Vetoshkin

    2017-01-01

    Full Text Available The development of new and modernization of existing aviation equipment specimens of different classes are ac- companied and completed by the complex process of ground and flight tests. This phase of aviation equipment life cycle is implemented by means of organizational and technical systems - running centers. The latter include various proving grounds, measuring complex and systems, aircraft, ships, security and flight control offices, information processing laborato- ries and many other elements. The system analysis results of development challenges of the automated control systems of aviation equipment tests operations are presented. The automated control systems are in essence an automated data bank. The key role of development of flight tests automated control system in the process of creation of the automated control sys- tems of aviation equipment tests operations is substantiated. The way of the mobile modular measuring complexes integra- tion and the need for national methodologies and technological standards for database systems design concepts are grounded. Database system, as a central element in this scheme, provides collection, storing and updating of values of the elements described above in pace and the required frequency of the controlled object state monitoring. It is database system that pro- vides the supervisory unit with actual data corresponding to specific moments of time, which concern the state processes, assessments of the progress and results of flight experiments, creating the necessary environment for aviation equipment managing and testing as a whole. The basis for development of subsystems of automated control systems of aviation equip- ment tests operations are conceptual design processes of the respective database system, the implementation effectiveness of which largely determines the level of success and ability to develop the systems being created. Introduced conclusions and suggestions can be used in the

  19. 用于统计测试概率分布生成的自动搜索方法%Automated Search Method for Statistical Test Probability Distribution Generation

    Institute of Scientific and Technical Information of China (English)

    周晓莹; 高建华

    2013-01-01

    A strategy based on automated search for probability distribution construction is proposed, which comprises the design of representation format and evaluation function for the probability distribution. Combining with simulated annealing algorithm, an indicator is defined to formalize the automated search process based on the Markov model. Experimental results show that the method effectively improves the accuracy of the automated search, which can reduce the expense of statistical test by providing the statistical test with fairly efficient test data since it successfully finds the neat-optimal probability distribution within a certain time.%提出一种基于自动搜索的概率分布生成方法,设计对概率分布的表示形式与评估函数,同时结合模拟退火算法设计基于马尔可夫模型的自动搜索过程.实验结果表明,该方法能够有效地提高自动搜索的准确性,在一定时间内成功找到接近最优的概率分布,生成高效的测试数据,同时达到降低统计测试成本的目的.

  20. Intraoperative Cochlear Implant Device Testing Utilizing an Automated Remote System: A Prospective Pilot Study.

    Science.gov (United States)

    Lohmann, Amanda R; Carlson, Matthew L; Sladen, Douglas P

    2018-03-01

    Intraoperative cochlear implant device testing provides valuable information regarding device integrity, electrode position, and may assist with determining initial stimulation settings. Manual intraoperative device testing during cochlear implantation requires the time and expertise of a trained audiologist. The purpose of the current study is to investigate the feasibility of using automated remote intraoperative cochlear implant reverse telemetry testing as an alternative to standard testing. Prospective pilot study evaluating intraoperative remote automated impedance and Automatic Neural Response Telemetry (AutoNRT) testing in 34 consecutive cochlear implant surgeries using the Intraoperative Remote Assistant (Cochlear Nucleus CR120). In all cases, remote intraoperative device testing was performed by trained operating room staff. A comparison was made to the "gold standard" of manual testing by an experienced cochlear implant audiologist. Electrode position and absence of tip fold-over was confirmed using plain film x-ray. Automated remote reverse telemetry testing was successfully completed in all patients. Intraoperative x-ray demonstrated normal electrode position without tip fold-over. Average impedance values were significantly higher using standard testing versus CR120 remote testing (standard mean 10.7 kΩ, SD 1.2 vs. CR120 mean 7.5 kΩ, SD 0.7, p automated testing with regard to the presence of open or short circuits along the array. There were, however, two cases in which standard testing identified an open circuit, when CR120 testing showed the circuit to be closed. Neural responses were successfully obtained in all patients using both systems. There was no difference in basal electrode responses (standard mean 195.0 μV, SD 14.10 vs. CR120 194.5 μV, SD 14.23; p = 0.7814); however, more favorable (lower μV amplitude) results were obtained with the remote automated system in the apical 10 electrodes (standard 185.4 μV, SD 11.69 vs. CR

  1. Grasping devices and methods in automated production processes

    DEFF Research Database (Denmark)

    Fantoni, Gualtiero; Santochi, Marco; Dini, Gino

    2014-01-01

    assembly to disassembly, from aerospace to food industry, from textile to logistics) are discussed. Finally, the most recent research is reviewed in order to introduce the new trends in grasping. They provide an outlook on the future of both grippers and robotic hands in automated production processes. (C......In automated production processes grasping devices and methods play a crucial role in the handling of many parts, components and products. This keynote paper starts with a classification of grasping phases, describes how different principles are adopted at different scales in different applications...

  2. Proceedings of Design, Automation and Test in Europe (DATE07)

    DEFF Research Database (Denmark)

    Welcome to the DATE 07 Conference Proceedings. DATE combines the world’s leading electronic systems design conference and Europe's leading international exhibition for electronic design, automation and test, from system level hardware and software implementation right down to integrated circuit...... with 78 sessions covering the latest in system design and embedded software, IC design methodologies and EDA tool developments. One of the main strengths of the conference is a wide but high-quality coverage of design, design automation and test topics, from the system level (including PCB and FPGA......) to the integrated circuit level. In addition, for the third year a special embedded software track is offered to allow for the increasing importance of software in embedded systems. Compared with previous years, submissions in design, test and embedded software have grown significantly, showing a clear trend toward...

  3. SmartUnit: Empirical Evaluations for Automated Unit Testing of Embedded Software in Industry

    OpenAIRE

    Zhang, Chengyu; Yan, Yichen; Zhou, Hanru; Yao, Yinbo; Wu, Ke; Su, Ting; Miao, Weikai; Pu, Geguang

    2018-01-01

    In this paper, we aim at the automated unit coverage-based testing for embedded software. To achieve the goal, by analyzing the industrial requirements and our previous work on automated unit testing tool CAUT, we rebuild a new tool, SmartUnit, to solve the engineering requirements that take place in our partner companies. SmartUnit is a dynamic symbolic execution implementation, which supports statement, branch, boundary value and MC/DC coverage. SmartUnit has been used to test more than one...

  4. Test oracle automation for V&V of an autonomous spacecraft's planner

    Science.gov (United States)

    Feather, M. S.; Smith, B.

    2001-01-01

    We built automation to assist the software testing efforts associated with the Remote Agent experiment. In particular, our focus was upon introducing test oracles into the testing of the planning and scheduling system component. This summary is intended to provide an overview of the work.

  5. Fully automated treatment planning for head and neck radiotherapy using a voxel-based dose prediction and dose mimicking method

    Science.gov (United States)

    McIntosh, Chris; Welch, Mattea; McNiven, Andrea; Jaffray, David A.; Purdie, Thomas G.

    2017-08-01

    Recent works in automated radiotherapy treatment planning have used machine learning based on historical treatment plans to infer the spatial dose distribution for a novel patient directly from the planning image. We present a probabilistic, atlas-based approach which predicts the dose for novel patients using a set of automatically selected most similar patients (atlases). The output is a spatial dose objective, which specifies the desired dose-per-voxel, and therefore replaces the need to specify and tune dose-volume objectives. Voxel-based dose mimicking optimization then converts the predicted dose distribution to a complete treatment plan with dose calculation using a collapsed cone convolution dose engine. In this study, we investigated automated planning for right-sided oropharaynx head and neck patients treated with IMRT and VMAT. We compare four versions of our dose prediction pipeline using a database of 54 training and 12 independent testing patients by evaluating 14 clinical dose evaluation criteria. Our preliminary results are promising and demonstrate that automated methods can generate comparable dose distributions to clinical. Overall, automated plans achieved an average of 0.6% higher dose for target coverage evaluation criteria, and 2.4% lower dose at the organs at risk criteria levels evaluated compared with clinical. There was no statistically significant difference detected in high-dose conformity between automated and clinical plans as measured by the conformation number. Automated plans achieved nine more unique criteria than clinical across the 12 patients tested and automated plans scored a significantly higher dose at the evaluation limit for two high-risk target coverage criteria and a significantly lower dose in one critical organ maximum dose. The novel dose prediction method with dose mimicking can generate complete treatment plans in 12-13 min without user interaction. It is a promising approach for fully automated treatment

  6. A catalog of automated analysis methods for enterprise models.

    Science.gov (United States)

    Florez, Hector; Sánchez, Mario; Villalobos, Jorge

    2016-01-01

    Enterprise models are created for documenting and communicating the structure and state of Business and Information Technologies elements of an enterprise. After models are completed, they are mainly used to support analysis. Model analysis is an activity typically based on human skills and due to the size and complexity of the models, this process can be complicated and omissions or miscalculations are very likely. This situation has fostered the research of automated analysis methods, for supporting analysts in enterprise analysis processes. By reviewing the literature, we found several analysis methods; nevertheless, they are based on specific situations and different metamodels; then, some analysis methods might not be applicable to all enterprise models. This paper presents the work of compilation (literature review), classification, structuring, and characterization of automated analysis methods for enterprise models, expressing them in a standardized modeling language. In addition, we have implemented the analysis methods in our modeling tool.

  7. Semi-automated extraction of longitudinal subglacial bedforms from digital terrain models - Two new methods

    Science.gov (United States)

    Jorge, Marco G.; Brennand, Tracy A.

    2017-07-01

    Relict drumlin and mega-scale glacial lineation (positive relief, longitudinal subglacial bedforms - LSBs) morphometry has been used as a proxy for paleo ice-sheet dynamics. LSB morphometric inventories have relied on manual mapping, which is slow and subjective and thus potentially difficult to reproduce. Automated methods are faster and reproducible, but previous methods for LSB semi-automated mapping have not been highly successful. Here, two new object-based methods for the semi-automated extraction of LSBs (footprints) from digital terrain models are compared in a test area in the Puget Lowland, Washington, USA. As segmentation procedures to create LSB-candidate objects, the normalized closed contour method relies on the contouring of a normalized local relief model addressing LSBs on slopes, and the landform elements mask method relies on the classification of landform elements derived from the digital terrain model. For identifying which LSB-candidate objects correspond to LSBs, both methods use the same LSB operational definition: a ruleset encapsulating expert knowledge, published morphometric data, and the morphometric range of LSBs in the study area. The normalized closed contour method was separately applied to four different local relief models, two computed in moving windows and two hydrology-based. Overall, the normalized closed contour method outperformed the landform elements mask method. The normalized closed contour method performed on a hydrological relief model from a multiple direction flow routing algorithm performed best. For an assessment of its transferability, the normalized closed contour method was evaluated on a second area, the Chautauqua drumlin field, Pennsylvania and New York, USA where it performed better than in the Puget Lowland. A broad comparison to previous methods suggests that the normalized relief closed contour method may be the most capable method to date, but more development is required.

  8. Drilling Automation Tests At A Lunar/Mars Analog Site

    Science.gov (United States)

    Glass, B.; Cannon, H.; Hanagud, S.; Lee, P.; Paulsen, G.

    2006-01-01

    Future in-situ lunar/martian resource utilization and characterization, as well as the scientific search for life on Mars, will require access to the subsurface and hence drilling. Drilling on Earth is hard - an art form more than an engineering discipline. The limited mass, energy and manpower in planetary drilling situations makes application of terrestrial drilling techniques problematic. The Drilling Automation for Mars Exploration (DAME) project is developing drilling automation and robotics for projected use in missions to the Moon and Mars in the 2011-15 period. This has been tested recently, drilling in permafrost at a lunar/martian analog site (Haughton Crater, Devon Island, Canada).

  9. Comparison of manual & automated analysis methods for corneal endothelial cell density measurements by specular microscopy.

    Science.gov (United States)

    Huang, Jianyan; Maram, Jyotsna; Tepelus, Tudor C; Modak, Cristina; Marion, Ken; Sadda, SriniVas R; Chopra, Vikas; Lee, Olivia L

    2017-08-07

    To determine the reliability of corneal endothelial cell density (ECD) obtained by automated specular microscopy versus that of validated manual methods and factors that predict such reliability. Sharp central images from 94 control and 106 glaucomatous eyes were captured with Konan specular microscope NSP-9900. All images were analyzed by trained graders using Konan CellChek Software, employing the fully- and semi-automated methods as well as Center Method. Images with low cell count (input cells number <100) and/or guttata were compared with the Center and Flex-Center Methods. ECDs were compared and absolute error was used to assess variation. The effect on ECD of age, cell count, cell size, and cell size variation was evaluated. No significant difference was observed between the Center and Flex-Center Methods in corneas with guttata (p=0.48) or low ECD (p=0.11). No difference (p=0.32) was observed in ECD of normal controls <40 yrs old between the fully-automated method and manual Center Method. However, in older controls and glaucomatous eyes, ECD was overestimated by the fully-automated method (p=0.034) and semi-automated method (p=0.025) as compared to manual method. Our findings show that automated analysis significantly overestimates ECD in the eyes with high polymegathism and/or large cell size, compared to the manual method. Therefore, we discourage reliance upon the fully-automated method alone to perform specular microscopy analysis, particularly if an accurate ECD value is imperative. Copyright © 2017. Published by Elsevier España, S.L.U.

  10. Verification Test of Automated Robotic Assembly of Space Truss Structures

    Science.gov (United States)

    Rhodes, Marvin D.; Will, Ralph W.; Quach, Cuong C.

    1995-01-01

    A multidisciplinary program has been conducted at the Langley Research Center to develop operational procedures for supervised autonomous assembly of truss structures suitable for large-aperture antennas. The hardware and operations required to assemble a 102-member tetrahedral truss and attach 12 hexagonal panels were developed and evaluated. A brute-force automation approach was used to develop baseline assembly hardware and software techniques. However, as the system matured and operations were proven, upgrades were incorporated and assessed against the baseline test results. These upgrades included the use of distributed microprocessors to control dedicated end-effector operations, machine vision guidance for strut installation, and the use of an expert system-based executive-control program. This paper summarizes the developmental phases of the program, the results of several assembly tests, and a series of proposed enhancements. No problems that would preclude automated in-space assembly or truss structures have been encountered. The test system was developed at a breadboard level and continued development at an enhanced level is warranted.

  11. Studies of criticality Monte Carlo method convergence: use of a deterministic calculation and automated detection of the transient

    International Nuclear Information System (INIS)

    Jinaphanh, A.

    2012-01-01

    Monte Carlo criticality calculation allows to estimate the effective multiplication factor as well as local quantities such as local reaction rates. Some configurations presenting weak neutronic coupling (high burn up profile, complete reactor core,...) may induce biased estimations for k eff or reaction rates. In order to improve robustness of the iterative Monte Carlo methods, a coupling with a deterministic code was studied. An adjoint flux is obtained by a deterministic calculation and then used in the Monte Carlo. The initial guess is then automated, the sampling of fission sites is modified and the random walk of neutrons is modified using splitting and russian roulette strategies. An automated convergence detection method has been developed. It locates and suppresses the transient due to the initialization in an output series, applied here to k eff and Shannon entropy. It relies on modeling stationary series by an order 1 auto regressive process and applying statistical tests based on a Student Bridge statistics. This method can easily be extended to every output of an iterative Monte Carlo. Methods developed in this thesis are tested on different test cases. (author)

  12. Feasibility studies of safety assessment methods for programmable automation systems. Final report of the AVV project

    International Nuclear Information System (INIS)

    Haapanen, P.; Maskuniitty, M.; Pulkkinen, U.; Heikkinen, J.; Korhonen, J.; Tuulari, E.

    1995-10-01

    Feasibility studies of two different groups of methodologies for safety assessment of programmable automation systems has been executed at the Technical Research Centre of Finland (VTT). The studies concerned the dynamic testing methods and the fault tree (FT) and failure mode and effects analysis (FMEA) methods. In order to get real experience in the application of these methods, an experimental testing of two realistic pilot systems were executed and a FT/FMEA analysis of a programmable safety function accomplished. The purpose of the studies was not to assess the object systems, but to get experience in the application of methods and assess their potentials and development needs. (46 refs., 21 figs.)

  13. Automated spectrophotometric bicarbonate analysis in duodenal juice compared to the back titration method.

    Science.gov (United States)

    Erchinger, Friedemann; Engjom, Trond; Gudbrandsen, Oddrun Anita; Tjora, Erling; Gilja, Odd H; Dimcevski, Georg

    2016-01-01

    We have recently evaluated a short endoscopic secretin test for exocrine pancreatic function. Bicarbonate concentration in duodenal juice is an important parameter in this test. Measurement of bicarbonate by back titration as the gold standard method is time consuming, expensive and technically difficult, thus a simplified method is warranted. We aimed to evaluate an automated spectrophotometric method in samples spanning the effective range of bicarbonate concentrations in duodenal juice. We also evaluated if freezing of samples before analyses would affect its results. Patients routinely examined with short endoscopic secretin test suspected to have decreased pancreatic function of various reasons were included. Bicarbonate in duodenal juice was quantified by back titration and automatic spectrophotometry. Both fresh and thawed samples were analysed spectrophotometrically. 177 samples from 71 patients were analysed. Correlation coefficient of all measurements was r = 0.98 (p titration gold standard. This is a major simplification of direct pancreas function testing, and allows a wider distribution of bicarbonate testing in duodenal juice. Extreme values for Bicarbonate concentration achieved by the autoanalyser method have to be interpreted with caution. Copyright © 2016 IAP and EPC. Published by Elsevier India Pvt Ltd. All rights reserved.

  14. Research issues in the automated testing of Ajax applications

    NARCIS (Netherlands)

    Van Deursen, A.; Mesbah, A.

    2009-01-01

    Note: This paper is a pre-print of: Arie van Deursen and Ali Mesbah. Research Issues in the Automated Testing of Ajax Applications. In Proceedings 36th International Conference on Current Trend in Theory and Practice of Computer Science (SOFSEM), pp. 16-28. Lecture Notes in Computer Science 5901,

  15. Uncertainties in the Item Parameter Estimates and Robust Automated Test Assembly

    Science.gov (United States)

    Veldkamp, Bernard P.; Matteucci, Mariagiulia; de Jong, Martijn G.

    2013-01-01

    Item response theory parameters have to be estimated, and because of the estimation process, they do have uncertainty in them. In most large-scale testing programs, the parameters are stored in item banks, and automated test assembly algorithms are applied to assemble operational test forms. These algorithms treat item parameters as fixed values,…

  16. Study radiolabeling of urea-based PSMA inhibitor with 68-Galliu: Comparative evaluation of automated and not automated methods

    International Nuclear Information System (INIS)

    Alcarde, Lais Fernanda

    2016-01-01

    The methods for clinical diagnosis of prostate cancer include rectal examination and the dosage of the prostatic specific antigen (PSA). However, the PSA level is elevated in about 20 to 30% of cases related to benign pathologies, resulting in false positives and leading patients to unnecessary biopsies. The prostate specific membrane antigen (PSMA), in contrast, is over expressed in prostate cancer and founded at low levels in healthy organs. As a result, it stimulated the development of small molecule inhibitors of PSMA, which carry imaging agents to the tumor and are not affected by their microvasculature. Recent studies suggest that the HBED-CC chelator intrinsically contributes to the binding of the PSMA inhibitor peptide based on urea (Glu-urea-Lys) to the pharmacophore group. This work describes the optimization of radiolabeling conditions of PSMA-HBED-CC with "6"8Ga, using automated system (synthesis module) and no automated method, seeking to establish an appropriate condition to prepare this new radiopharmaceutical, with emphasis on the labeling yield and radiochemical purity of the product. It also aimed to evaluate the stability of the radiolabeled peptide in transport conditions and study the biological distribution of the radiopharmaceutical in healthy mice. The study of radiolabeling parameters enabled to define a non-automated method which resulted in high radiochemical purity (> 95 %) without the need for purification of the labeled peptide. The automated method has been adapted, using a module of synthesis and software already available at IPEN, and also resulted in high synthetic yield (≥ 90%) specially when compared with those described in the literature, with the associated benefit of greater control of the production process in compliance with Good Manufacturing Practices. The study of radiolabeling parameters afforded the PSMA-HBED-CC-"6"8Ga with higher specific activity than observed in published clinical studies (≥ 140,0 GBq

  17. Lifecycle, Iteration, and Process Automation with SMS Gateway

    Directory of Open Access Journals (Sweden)

    Fenny Fenny

    2015-12-01

    Full Text Available Producing a better quality software system requires an understanding of the indicators of the software quality through defect detection, and automated testing. This paper aims to elevate the design and automated testing process in an engine water pump of a drinking water plant. This paper proposes how software developers can improve the maintainability and reliability of automated testing system and report the abnormal state when an error occurs on the machine. The method in this paper uses literature to explain best practices and case studies of a drinking water plant. Furthermore, this paper is expected to be able to provide insights into the efforts to better handle errors and perform automated testing and monitoring on a machine.

  18. Contact method or automated immersion technique: possible application and limitations of ultrasonic testing in the fusion reactor; Kontakttechnik oder automatisierte Tauchtechnik. Einsatzmoeglichkeiten und Beschraenkungen der Ultraschallpruefung im Fusionsreaktor

    Energy Technology Data Exchange (ETDEWEB)

    Martin, Tatiana; Knaak, Stefan; Aktaa, Jarir [Karlsruher Institut fuer Technologie (KIT), Eggenstein-Leopoldshafen (Germany). Inst. fuer Angewandte Materialien Werkstoff- und Biomechanik (IAM-WBM); Rey, Joerg; Neuberger, Heiko [Karlsruher Institut fuer Technologie (KIT), Eggenstein-Leopoldshafen (Germany). Inst. fuer Neutronenphysik und Reaktortechnik (INR); Krueger, Friedhelm [Krueger Erodiertechnik GmbH und Co.KG, Biedenkopf (Germany); Karlsruher Institut fuer Technologie (KIT), Eggenstein-Leopoldshafen (Germany)

    2014-11-01

    The tritium breeding blanket is the most important component of a thermonuclear reactor combining the protective function against plasma impact and heat exchange. The breeding blanket concept is based on the use of helium as coolant and beryllium pebbles as neutron multiplier. As structural material the low-activation ferritic-martensitic steel EUROFER (9Cr-W-V-T) is used. For quality assurance the components of the breeding blankets are tested using different non-destructive testing methods. The contact methodology applies the testing equipment VEO in combination of the 10 MHz array-wheel sensor of the ultrasonic phased array series. Immersion testing is performed using the automated facility KC 200 from GE Inspection technologies.

  19. Development and verification testing of automation and robotics for assembly of space structures

    Science.gov (United States)

    Rhodes, Marvin D.; Will, Ralph W.; Quach, Cuong C.

    1993-01-01

    A program was initiated within the past several years to develop operational procedures for automated assembly of truss structures suitable for large-aperture antennas. The assembly operations require the use of a robotic manipulator and are based on the principle of supervised autonomy to minimize crew resources. A hardware testbed was established to support development and evaluation testing. A brute-force automation approach was used to develop the baseline assembly hardware and software techniques. As the system matured and an operation was proven, upgrades were incorprated and assessed against the baseline test results. This paper summarizes the developmental phases of the program, the results of several assembly tests, the current status, and a series of proposed developments for additional hardware and software control capability. No problems that would preclude automated in-space assembly of truss structures have been encountered. The current system was developed at a breadboard level and continued development at an enhanced level is warranted.

  20. Automated Methods Of Corrosion Measurements

    DEFF Research Database (Denmark)

    Bech-Nielsen, Gregers; Andersen, Jens Enevold Thaulov; Reeve, John Ch

    1997-01-01

    The chapter describes the following automated measurements: Corrosion Measurements by Titration, Imaging Corrosion by Scanning Probe Microscopy, Critical Pitting Temperature and Application of the Electrochemical Hydrogen Permeation Cell.......The chapter describes the following automated measurements: Corrosion Measurements by Titration, Imaging Corrosion by Scanning Probe Microscopy, Critical Pitting Temperature and Application of the Electrochemical Hydrogen Permeation Cell....

  1. Automated X-ray television complex for testing large dynamic objects

    International Nuclear Information System (INIS)

    Gusev, E.A.; Luk'yanenko, Eh.A.; Chelnokov, V.B.; Kuleshov, V.K.; Alkhimov, Yu.V.

    1992-01-01

    An automated X-ray television complex on the base of matrix gas-dischage large-area (2.1x1.0 m) converter for testing large cargoes and containers, as well as for inductrial article diagnostics is described. The complex pulsed operation with the 512 kbytes television digital memory unit provides for testing dynamic objects under minimal doses (20-100 μR)

  2. Construct validity and reliability of automated body reaction test ...

    African Journals Online (AJOL)

    Automated Body Reaction Test (ABRT) is a new device for skills and physical assessment instrument to measure ability on react, move quickly and accurately in accordance with stimulus. A total of 474 subjects aged 7-17 years old were randomly selected for the construct validity (n=330) and reliability (n=144). The ABRT ...

  3. Multi-Sensor Testing for Automated Rendezvous and Docking Sensor Testing at the Flight Robotics Laboratory

    Science.gov (United States)

    Brewster, L.; Johnston, A.; Howard, R.; Mitchell, J.; Cryan, S.

    2007-01-01

    The Exploration Systems Architecture defines missions that require rendezvous, proximity operations, and docking (RPOD) of two spacecraft both in Low Earth Orbit (LEO) and in Low Lunar Orbit (LLO). Uncrewed spacecraft must perform automated and/or autonomous rendezvous, proximity operations and docking operations (commonly known as AR&D). The crewed missions may also perform rendezvous and docking operations and may require different levels of automation and/or autonomy, and must provide the crew with relative navigation information for manual piloting. The capabilities of the RPOD sensors are critical to the success of the Exploration Program. NASA has the responsibility to determine whether the Crew Exploration Vehicle (CEV) contractor proposed relative navigation sensor suite will meet the requirements. The relatively low technology readiness level of AR&D relative navigation sensors has been carried as one of the CEV Project's top risks. The AR&D Sensor Technology Project seeks to reduce the risk by the testing and analysis of selected relative navigation sensor technologies through hardware-in-the-loop testing and simulation. These activities will provide the CEV Project information to assess the relative navigation sensors maturity as well as demonstrate test methods and capabilities. The first year of this project focused on a series of"pathfinder" testing tasks to develop the test plans, test facility requirements, trajectories, math model architecture, simulation platform, and processes that will be used to evaluate the Contractor-proposed sensors. Four candidate sensors were used in the first phase of the testing. The second phase of testing used four sensors simultaneously: two Marshall Space Flight Center (MSFC) Advanced Video Guidance Sensors (AVGS), a laser-based video sensor that uses retroreflectors attached to the target vehicle, and two commercial laser range finders. The multi-sensor testing was conducted at MSFC's Flight Robotics Laboratory (FRL

  4. Multi-Sensor Testing for Automated Rendezvous and Docking Sensor Testing at the Flight Robotics Lab

    Science.gov (United States)

    Brewster, Linda L.; Howard, Richard T.; Johnston, A. S.; Carrington, Connie; Mitchell, Jennifer D.; Cryan, Scott P.

    2008-01-01

    The Exploration Systems Architecture defines missions that require rendezvous, proximity operations, and docking (RPOD) of two spacecraft both in Low Earth Orbit (LEO) and in Low Lunar Orbit (LLO). Uncrewed spacecraft must perform automated and/or autonomous rendezvous, proximity operations and docking operations (commonly known as AR&D). The crewed missions may also perform rendezvous and docking operations and may require different levels of automation and/or autonomy, and must provide the crew with relative navigation information for manual piloting. The capabilities of the RPOD sensors are critical to the success ofthe Exploration Program. NASA has the responsibility to determine whether the Crew Exploration Vehicle (CEV) contractor-proposed relative navigation sensor suite will meet the requirements. The relatively low technology readiness level of AR&D relative navigation sensors has been carried as one of the CEV Project's top risks. The AR&D Sensor Technology Project seeks to reduce the risk by the testing and analysis of selected relative navigation sensor technologies through hardware-in-the-Ioop testing and simulation. These activities will provide the CEV Project information to assess the relative navigation sensors maturity as well as demonstrate test methods and capabilities. The first year of this project focused on a series of "pathfinder" testing tasks to develop the test plans, test facility requirements, trajectories, math model architecture, simulation platform, and processes that will be used to evaluate the Contractor-proposed sensors. Four candidate sensors were used in the first phase of the testing. The second phase of testing used four sensors simultaneously: two Marshall Space Flight Center (MSFC) Advanced Video Guidance Sensors (AVGS), a laser-based video sensor that uses retroreflectors attached to the target vehicle, and two commercial laser range finders. The multi-sensor testing was conducted at MSFC's Flight Robotics Laboratory (FRL

  5. An Automated Test Framework for Experimenting with Stochastic Behavior in Reconfigurable Logic

    DEFF Research Database (Denmark)

    Birklykke, Alex Aaen; Le Moullec, Yannick; Alminde, Lars

    2012-01-01

    In this paper, we present an automated test frame- work for the characterization of stochastic behavior in logic circuits. The framework is intended as a platform for experimenting with and providing statistics on digital architectures given behavioral uncertainties at the gate-level. As an exper......In this paper, we present an automated test frame- work for the characterization of stochastic behavior in logic circuits. The framework is intended as a platform for experimenting with and providing statistics on digital architectures given behavioral uncertainties at the gate...... block subject to voltage/frequency scaling and Vdd -noise. The framework provides easy interfacing with laboratory equipment, design of experiment capabilities and automatic test execution, thus providing a powerful tool for characterizing stochastic behavior in reconfigurable logic....

  6. Flexible Method for the Automated Offline-Detection of Artifacts in Multi-Channel Electroencephalogram Recordings

    DEFF Research Database (Denmark)

    Waser, Markus; Garn, Heinrich; Benke, Thomas

    2017-01-01

    . However, these preprocessing steps do not allow for complete artifact correction. We propose a method for the automated offline-detection of remaining artifacts after preprocessing in multi-channel EEG recordings. In contrast to existing methods it requires neither adaptive parameters varying between...... recordings nor a topography template. It is suited for short EEG segments and is flexible with regard to target applications. The algorithm was developed and tested on 60 clinical EEG samples of 20 seconds each that were recorded both in resting state and during cognitive activation to gain a realistic...

  7. Validation Testing for Automated Solubility Measurement Equipment Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Lachut, J. S. [Washington River Protection Solutions LLC, Richland, WA (United States)

    2016-01-11

    Laboratory tests have been completed to test the validity of automated solubility measurement equipment using sodium nitrate and sodium chloride solutions (see test plan WRPS-1404441, “Validation Testing for Automated Solubility Measurement Equipment”). The sodium nitrate solution results were within 2-3% of the reference values, so the experiment is considered successful using the turbidity meter. The sodium chloride test was done by sight, as the turbidity meter did not work well using sodium chloride. For example, the “clear” turbidity reading was 53 FNU at 80 °C, 107 FNU at 55 °C, and 151 FNU at 20 °C. The sodium chloride did not work because it is granular and large; as the solution was stirred, the granules stayed to the outside of the reactor and just above the stir bar level, having little impact on the turbidity meter readings as the meter was aimed at the center of the solution. Also, the turbidity meter depth has an impact. The salt tends to remain near the stir bar level. If the meter is deeper in the slurry, it will read higher turbidity, and if the meter is raised higher in the slurry, it will read lower turbidity (possibly near zero) because it reads the “clear” part of the slurry. The sodium chloride solution results, as measured by sight rather than by turbidity instrument readings, were within 5-6% of the reference values.

  8. A computer-controlled automated test system for fatigue and fracture testing

    International Nuclear Information System (INIS)

    Nanstad, R.K.; Alexander, D.J.; Swain, R.L.; Hutton, J.T.; Thomas, D.L.

    1989-01-01

    A computer-controlled system consisting of a servohydraulic test machine, an in-house designed test controller, and a desktop computer has been developed for performing automated fracture toughness and fatigue crack growth testing both in the laboratory and in hot cells for remote testing of irradiated specimens. Both unloading compliance and dc-potential drop can be used to monitor crack growth. The test controller includes a dc-current supply programmer, a function generator for driving the servohydraulic test machine to required test outputs, five measurement channels (each consisting of low-pass filter, track/hold amplifier, and 16-bit analog-to-digital converter), and digital logic for various control and data multiplexing functions. The test controller connects to the computer via a 16-bit wide photo-isolated bidirectional bus. The computer, a Hewlett-Packard series 200/300, inputs specimen and test parameters from the operator, configures the test controller, stores test data from the test controller in memory, does preliminary analysis during the test, and records sensor calibrations, specimen and test parameters, and test data on flexible diskette for later recall and analysis with measured initial and final crack length information. During the test, the operator can change test parameters as necessary. 24 refs., 6 figs

  9. Economic and workflow analysis of a blood bank automated system.

    Science.gov (United States)

    Shin, Kyung-Hwa; Kim, Hyung Hoi; Chang, Chulhun L; Lee, Eun Yup

    2013-07-01

    This study compared the estimated costs and times required for ABO/Rh(D) typing and unexpected antibody screening using an automated system and manual methods. The total cost included direct and labor costs. Labor costs were calculated on the basis of the average operator salaries and unit values (minutes), which was the hands-on time required to test one sample. To estimate unit values, workflows were recorded on video, and the time required for each process was analyzed separately. The unit values of ABO/Rh(D) typing using the manual method were 5.65 and 8.1 min during regular and unsocial working hours, respectively. The unit value was less than 3.5 min when several samples were tested simultaneously. The unit value for unexpected antibody screening was 2.6 min. The unit values using the automated method for ABO/Rh(D) typing, unexpected antibody screening, and both simultaneously were all 1.5 min. The total cost of ABO/Rh(D) typing of only one sample using the automated analyzer was lower than that of testing only one sample using the manual technique but higher than that of testing several samples simultaneously. The total cost of unexpected antibody screening using an automated analyzer was less than that using the manual method. ABO/Rh(D) typing using an automated analyzer incurs a lower unit value and cost than that using the manual technique when only one sample is tested at a time. Unexpected antibody screening using an automated analyzer always incurs a lower unit value and cost than that using the manual technique.

  10. Automated aerosol sampling and analysis for the Comprehensive Test Ban Treaty

    International Nuclear Information System (INIS)

    Miley, H.S.; Bowyer, S.M.; Hubbard, C.W.; McKinnon, A.D.; Perkins, R.W.; Thompson, R.C.; Warner, R.A.

    1998-01-01

    Detecting nuclear debris from a nuclear weapon exploded in or substantially vented to the Earth's atmosphere constitutes the most certain indication that a violation of the Comprehensive Test Ban Treaty has occurred. For this reason, a radionuclide portion of the International Monitoring System is being designed and implemented. The IMS will monitor aerosols and gaseous xenon isotopes to detect atmospheric and underground tests, respectively. An automated system, the Radionuclide Aerosol Sampler/Analyzer (RASA), has been developed at Pacific Northwest National Laboratory to meet CTBT aerosol measurement requirements. This is achieved by the use of a novel sampling apparatus, a high-resolution germanium detector, and very sophisticated software. This system draws a large volume of air (∼ 20,000 m 3 /day), performs automated gamma-ray spectral measurements (MDC( 140 Ba) 3 ), and communicates this and other data to a central data facility. Automated systems offer the added benefit of rigid controls, easily implemented QA/QC procedures, and centralized depot maintenance and operation. Other types of automated communication include pull or push transmission of State-Of-Health data, commands, and configuration data. In addition, a graphical user interface, Telnet, and other interactive communications are supported over ordinary phone or network lines. This system has been the subject of a USAF commercialization effort to meet US CTBT monitoring commitments. It will also be available to other CTBT signatories and the monitoring community for various governmental, environmental, or commercial needs. The current status of the commercialization is discussed

  11. Automated Analysis of Human Sperm Number and Concentration (Oligospermia) Using Otsu Threshold Method and Labelling

    Science.gov (United States)

    Susrama, I. G.; Purnama, K. E.; Purnomo, M. H.

    2016-01-01

    Oligospermia is a male fertility issue defined as a low sperm concentration in the ejaculate. Normally the sperm concentration is 20-120 million/ml, while Oligospermia patients has sperm concentration less than 20 million/ml. Sperm test done in the fertility laboratory to determine oligospermia by checking fresh sperm according to WHO standards in 2010 [9]. The sperm seen in a microscope using a Neubauer improved counting chamber and manually count the number of sperm. In order to be counted automatically, this research made an automation system to analyse and count the sperm concentration called Automated Analysis of Sperm Concentration Counters (A2SC2) using Otsu threshold segmentation process and morphology. Data sperm used is the fresh sperm directly in the analysis in the laboratory from 10 people. The test results using A2SC2 method obtained an accuracy of 91%. Thus in this study, A2SC2 can be used to calculate the amount and concentration of sperm automatically

  12. An automated repair method of water pipe infrastructure using carbon fiber bundles

    Science.gov (United States)

    Wisotzkey, Sean; Carr, Heath; Fyfe, Ed

    2011-04-01

    The United States water pipe infrastructure is made up of over 2 million miles of pipe. Due to age and deterioration, a large portion of this pipe is in need of repair to prevent catastrophic failures. Current repair methods generally involve intrusive techniques that can be time consuming and costly, but also can cause major societal impacts. A new automated repair method incorporating innovative carbon fiber technology is in development. This automated method would eliminate the need for trenching and would vastly cut time and labor costs, providing a much more economical pipe repair solution.

  13. An engineer's guide to automated testing of high-speed interfaces

    CERN Document Server

    Moreira, Jose

    2010-01-01

    Providing a complete introduction to the state-of-the-art in high-speed digital testing with automated test equipment (ATE), this practical resource is the first book focus exclusively on this increasingly important topic. Featuring clear examples, this one-stop reference covers all critical aspects of the subject, from high-speed digital basics, ATE instrumentation for digital applications, and test and measurements, to production testing, support instrumentation and text fixture design. This in-depth volume also discusses at advanced ATE topics, such as multiplexing of ATE pin channels and t

  14. Field test of the PNNL Automated Radioxenon Sampler/Analyzer (ARSA)

    International Nuclear Information System (INIS)

    Lagomarsino, R.J.; Ku, E.; Latner, N.; Sanderson, C.G.

    1998-07-01

    As part of the requirements of the Comprehensive Test Ban Treaty (CTBT), the Automated Radioxenon/Sampler Analyzer (ARSA) was designed and engineered by the Pacific Northwest National Laboratory (PNNL). The instrument is to provide near real-time detection and measurement of the radioxenons released into the atmosphere after a nuclear test. Forty-six field tests, designed to determine the performance of the ARSA prototype under simulated field conditions, were conducted at EML from March to December 1997. This final report contains detailed results of the tests with recommendations for improvements in instrument performance

  15. Field test of the PNNL Automated Radioxenon Sampler/Analyzer (ARSA)

    Energy Technology Data Exchange (ETDEWEB)

    Lagomarsino, R.J.; Ku, E.; Latner, N.; Sanderson, C.G.

    1998-07-01

    As part of the requirements of the Comprehensive Test Ban Treaty (CTBT), the Automated Radioxenon/Sampler Analyzer (ARSA) was designed and engineered by the Pacific Northwest National Laboratory (PNNL). The instrument is to provide near real-time detection and measurement of the radioxenons released into the atmosphere after a nuclear test. Forty-six field tests, designed to determine the performance of the ARSA prototype under simulated field conditions, were conducted at EML from March to December 1997. This final report contains detailed results of the tests with recommendations for improvements in instrument performance.

  16. The Halden Reactor Project workshop meeting on human centred automation and function allocation methods

    International Nuclear Information System (INIS)

    Sebok, Angelia; Green, Marit; Larsen, Marit; Miberg, Ann Britt; Morisseau, Dolores

    1998-02-01

    A workshop on Human Centred Automation (HCA) and Function Allocation Methods was organised in Halden, September 29-30, 1997. The purpose of the workshop was to discuss and make recommendations on requirements for the Halden Project research agenda. The workshop meeting began with several presentations summarising current issues in HCA, Function Allocation Methods and Functional Modelling. Invited speakers presented their research or modelling efforts. Following the presentations, the workshop was divided into three working groups, all tasked with answering the same four questions: (1) What are the most important issues in Human Centred Automation? (2) Which strengths could be achieved by integrating Functional Modelling Methods into experimental Human Centred Automation research? (3) How should analytical and experimental methods be balanced? (4) What are the most important aspects in automation design methodology? Each group discussed the questions and produced specific recommendations that were summarised by the group's facilitator in a joint session of the workshop. (author)

  17. A production throughput forecasting system in an automated hard disk drive test operation using GRNN

    Energy Technology Data Exchange (ETDEWEB)

    Samattapapong, N.; Afzulpurkar, N.

    2016-07-01

    The goal of this paper is to develop a pragmatic system of a production throughput forecasting system for an automated test operation in a hard drive manufacturing plant. The accurate forecasting result is necessary for the management team to response to any changes in the production processes and the resources allocations. In this study, we design a production throughput forecasting system in an automated test operation in hard drive manufacturing plant. In the proposed system, consists of three main stages. In the first stage, a mutual information method was adopted for selecting the relevant inputs into the forecasting model. In the second stage, a generalized regression neural network (GRNN) was implemented in the forecasting model development phase. Finally, forecasting accuracy was improved by searching the optimal smoothing parameter which selected from comparisons result among three optimization algorithms: particle swarm optimization (PSO), unrestricted search optimization (USO) and interval halving optimization (IHO). The experimental result shows that (1) the developed production throughput forecasting system using GRNN is able to provide forecasted results close to actual values, and to projected the future trends of production throughput in an automated hard disk drive test operation; (2) An IHO algorithm performed as superiority appropriate optimization method than the other two algorithms. (3) Compared with current forecasting system in manufacturing, the results show that the proposed system’s performance is superior to the current system in prediction accuracy and suitable for real-world application. The production throughput volume is a key performance index of hard disk drive manufacturing systems that need to be forecast. Because of the production throughput forecasting result is useful information for management team to respond to any changing in production processes and resources allocation. However, a practically forecasting system for

  18. Evaluation of a fully automated treponemal test and comparison with conventional VDRL and FTA-ABS tests.

    Science.gov (United States)

    Park, Yongjung; Park, Younhee; Joo, Shin Young; Park, Myoung Hee; Kim, Hyon-Suk

    2011-11-01

    We evaluated analytic performances of an automated treponemal test and compared this test with the Venereal Disease Research Laboratory test (VDRL) and fluorescent treponemal antibody absorption test (FTA-ABS). Precision performance of the Architect Syphilis TP assay (TP; Abbott Japan, Tokyo, Japan) was assessed, and 150 serum samples were assayed with the TP before and after heat inactivation to estimate the effect of heat inactivation. A total of 616 specimens were tested with the FTA-ABS and TP, and 400 were examined with the VDRL. The TP showed good precision performance with total imprecision of less than a 10% coefficient of variation. An excellent linear relationship between results before and after heat inactivation was observed (R(2) = 0.9961). The FTA-ABS and TP agreed well with a κ coefficient of 0.981. The concordance rate between the FTA-ABS and TP was the highest (99.0%), followed by the rates between FTA-ABS and VDRL (85.0%) and between TP and VDRL (83.8%). The automated TP assay may be adequate for screening for syphilis in a large volume of samples and can be an alternative to FTA-ABS.

  19. Automated Smoke Testing on the JVM with Geb

    CERN Multimedia

    CERN. Geneva

    2015-01-01

    to prevent catastrophic failures from reaching the production environment. We will show how we have leveraged Geb -- a browser automation tool built on top of Selenium -- to develop a full suite of smoke tests for CERN's Electronic Document Handling (EDH) system -- a large web application with over 1 million lines of Java code, in production since 1998. Though the tool is aimed for use on the JVM, the concepts that will be presented can be applied in other languages that have wrappers for Selenium. In particular, patterns that can be used to better describe and structure functional/smoke tests, as well as how to integrate these tests with continuous integration systems, such as Atlassian Bamboo, using headless browsers (e.g. PhantomJS) or virtual frame buffers.

  20. CATS, continuous automated testing of seismological, hydroacoustic, and infrasound (SHI) processing software.

    Science.gov (United States)

    Brouwer, Albert; Brown, David; Tomuta, Elena

    2017-04-01

    To detect nuclear explosions, waveform data from over 240 SHI stations world-wide flows into the International Data Centre (IDC) of the Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO), located in Vienna, Austria. A complex pipeline of software applications processes this data in numerous ways to form event hypotheses. The software codebase comprises over 2 million lines of code, reflects decades of development, and is subject to frequent enhancement and revision. Since processing must run continuously and reliably, software changes are subjected to thorough testing before being put into production. To overcome the limitations and cost of manual testing, the Continuous Automated Testing System (CATS) has been created. CATS provides an isolated replica of the IDC processing environment, and is able to build and test different versions of the pipeline software directly from code repositories that are placed under strict configuration control. Test jobs are scheduled automatically when code repository commits are made. Regressions are reported. We present the CATS design choices and test methods. Particular attention is paid to how the system accommodates the individual testing of strongly interacting software components that lack test instrumentation.

  1. Early detection of pharmacovigilance signals with automated methods based on false discovery rates: a comparative study.

    Science.gov (United States)

    Ahmed, Ismaïl; Thiessard, Frantz; Miremont-Salamé, Ghada; Haramburu, Françoise; Kreft-Jais, Carmen; Bégaud, Bernard; Tubert-Bitter, Pascale

    2012-06-01

    Improving the detection of drug safety signals has led several pharmacovigilance regulatory agencies to incorporate automated quantitative methods into their spontaneous reporting management systems. The three largest worldwide pharmacovigilance databases are routinely screened by the lower bound of the 95% confidence interval of proportional reporting ratio (PRR₀₂.₅), the 2.5% quantile of the Information Component (IC₀₂.₅) or the 5% quantile of the Gamma Poisson Shrinker (GPS₀₅). More recently, Bayesian and non-Bayesian False Discovery Rate (FDR)-based methods were proposed that address the arbitrariness of thresholds and allow for a built-in estimate of the FDR. These methods were also shown through simulation studies to be interesting alternatives to the currently used methods. The objective of this work was twofold. Based on an extensive retrospective study, we compared PRR₀₂.₅, GPS₀₅ and IC₀₂.₅ with two FDR-based methods derived from the Fisher's exact test and the GPS model (GPS(pH0) [posterior probability of the null hypothesis H₀ calculated from the Gamma Poisson Shrinker model]). Secondly, restricting the analysis to GPS(pH0), we aimed to evaluate the added value of using automated signal detection tools compared with 'traditional' methods, i.e. non-automated surveillance operated by pharmacovigilance experts. The analysis was performed sequentially, i.e. every month, and retrospectively on the whole French pharmacovigilance database over the period 1 January 1996-1 July 2002. Evaluation was based on a list of 243 reference signals (RSs) corresponding to investigations launched by the French Pharmacovigilance Technical Committee (PhVTC) during the same period. The comparison of detection methods was made on the basis of the number of RSs detected as well as the time to detection. Results comparing the five automated quantitative methods were in favour of GPS(pH0) in terms of both number of detections of true signals and

  2. Automation and Evaluation of the SOWH Test with SOWHAT.

    Science.gov (United States)

    Church, Samuel H; Ryan, Joseph F; Dunn, Casey W

    2015-11-01

    The Swofford-Olsen-Waddell-Hillis (SOWH) test evaluates statistical support for incongruent phylogenetic topologies. It is commonly applied to determine if the maximum likelihood tree in a phylogenetic analysis is significantly different than an alternative hypothesis. The SOWH test compares the observed difference in log-likelihood between two topologies to a null distribution of differences in log-likelihood generated by parametric resampling. The test is a well-established phylogenetic method for topology testing, but it is sensitive to model misspecification, it is computationally burdensome to perform, and its implementation requires the investigator to make several decisions that each have the potential to affect the outcome of the test. We analyzed the effects of multiple factors using seven data sets to which the SOWH test was previously applied. These factors include a number of sample replicates, likelihood software, the introduction of gaps to simulated data, the use of distinct models of evolution for data simulation and likelihood inference, and a suggested test correction wherein an unresolved "zero-constrained" tree is used to simulate sequence data. To facilitate these analyses and future applications of the SOWH test, we wrote SOWHAT, a program that automates the SOWH test. We find that inadequate bootstrap sampling can change the outcome of the SOWH test. The results also show that using a zero-constrained tree for data simulation can result in a wider null distribution and higher p-values, but does not change the outcome of the SOWH test for most of the data sets tested here. These results will help others implement and evaluate the SOWH test and allow us to provide recommendations for future applications of the SOWH test. SOWHAT is available for download from https://github.com/josephryan/SOWHAT. © The Author(s) 2015. Published by Oxford University Press, on behalf of the Society of Systematic Biologists.

  3. The Science of Home Automation

    Science.gov (United States)

    Thomas, Brian Louis

    Smart home technologies and the concept of home automation have become more popular in recent years. This popularity has been accompanied by social acceptance of passive sensors installed throughout the home. The subsequent increase in smart homes facilitates the creation of home automation strategies. We believe that home automation strategies can be generated intelligently by utilizing smart home sensors and activity learning. In this dissertation, we hypothesize that home automation can benefit from activity awareness. To test this, we develop our activity-aware smart automation system, CARL (CASAS Activity-aware Resource Learning). CARL learns the associations between activities and device usage from historical data and utilizes the activity-aware capabilities to control the devices. To help validate CARL we deploy and test three different versions of the automation system in a real-world smart environment. To provide a foundation of activity learning, we integrate existing activity recognition and activity forecasting into CARL home automation. We also explore two alternatives to using human-labeled data to train the activity learning models. The first unsupervised method is Activity Detection, and the second is a modified DBSCAN algorithm that utilizes Dynamic Time Warping (DTW) as a distance metric. We compare the performance of activity learning with human-defined labels and with automatically-discovered activity categories. To provide evidence in support of our hypothesis, we evaluate CARL automation in a smart home testbed. Our results indicate that home automation can be boosted through activity awareness. We also find that the resulting automation has a high degree of usability and comfort for the smart home resident.

  4. Computers, coders, and voters: Comparing automated methods for estimating party positions

    DEFF Research Database (Denmark)

    Hjorth, F.; Klemmensen, R.; Hobolt, S.

    2015-01-01

    Assigning political actors positions in ideological space is a task of key importance to political scientists. In this paper we compare estimates obtained using the automated Wordscores and Wordfish techniques, along with estimates from voters and the Comparative Manifesto Project (CMP), against...... texts and a more ideologically charged vocabulary in order to produce estimates comparable to Wordscores. The paper contributes to the literature on automated content analysis by providing a comprehensive test of convergent validation, in terms of both number of cases analyzed and number of validation...

  5. Automated testing and reverification for training simulators using SATAR

    International Nuclear Information System (INIS)

    Charles, R.D.; Gaddy, C.D.; Nargarkar, A.; Colley, R.

    1990-01-01

    This paper reports that simulators used to train nuclear power plant operators must be recertified periodically to ensure fidelity for training (10 CFR 55.45). The objective of the Simulator Automated Testing and Reverification (SATAR) project was to develop software to reverify dynamic simulator performance automatically. The software resides in a standard configuration personal computer and in the simulator computer; the two computers are linked via serial ports. SATAR will automatically run performance tests, collect and analyze data, and compare data with baseline performance data. With SATAR, support from operations and simulator support personnel can be reduced greatly, and the repeatability of performance tests can be improved

  6. Automated search method for AFM and profilers

    Science.gov (United States)

    Ray, Michael; Martin, Yves C.

    2001-08-01

    A new automation software creates a search model as an initial setup and searches for a user-defined target in atomic force microscopes or stylus profilometers used in semiconductor manufacturing. The need for such automation has become critical in manufacturing lines. The new method starts with a survey map of a small area of a chip obtained from a chip-design database or an image of the area. The user interface requires a user to point to and define a precise location to be measured, and to select a macro function for an application such as line width or contact hole. The search algorithm automatically constructs a range of possible scan sequences within the survey, and provides increased speed and functionality compared to the methods used in instruments to date. Each sequence consists in a starting point relative to the target, a scan direction, and a scan length. The search algorithm stops when the location of a target is found and criteria for certainty in positioning is met. With today's capability in high speed processing and signal control, the tool can simultaneously scan and search for a target in a robotic and continuous manner. Examples are given that illustrate the key concepts.

  7. A new automated colorimetric method for measuring total oxidant status.

    Science.gov (United States)

    Erel, Ozcan

    2005-12-01

    To develop a new, colorimetric and automated method for measuring total oxidation status (TOS). The assay is based on the oxidation of ferrous ion to ferric ion in the presence of various oxidant species in acidic medium and the measurement of the ferric ion by xylenol orange. The oxidation reaction of the assay was enhanced and precipitation of proteins was prevented. In addition, autoxidation of ferrous ion present in the reagent was prevented during storage. The method was applied to an automated analyzer, which was calibrated with hydrogen peroxide and the analytical performance characteristics of the assay were determined. There were important correlations with hydrogen peroxide, tert-butyl hydroperoxide and cumene hydroperoxide solutions (r=0.99, Ptotal antioxidant capacity (TAC) (r=-0.66 Ptotal oxidant status.

  8. Multi-method automated diagnostics of rotating machines

    Science.gov (United States)

    Kostyukov, A. V.; Boychenko, S. N.; Shchelkanov, A. V.; Burda, E. A.

    2017-08-01

    The automated machinery diagnostics and monitoring systems utilized within the petrochemical plants are an integral part of the measures taken to ensure safety and, as a consequence, the efficiency of these industrial facilities. Such systems are often limited in their functionality due to the specifics of the diagnostic techniques adopted. As the diagnostic techniques applied in each system are limited, and machinery defects can have different physical nature, it becomes necessary to combine several diagnostics and monitoring systems to control various machinery components. Such an approach is inconvenient, since it requires additional measures to bring the diagnostic results in a single view of the technical condition of production assets. In this case, we mean by a production facility a bonded complex of a process unit, a drive, a power source and lines. A failure of any of these components will cause an outage of the production asset, which is unacceptable. The purpose of the study is to test a combined use of vibration diagnostics and partial discharge techniques within the diagnostic systems of enterprises for automated control of the technical condition of rotating machinery during maintenance and at production facilities. The described solutions allow you to control the condition of mechanical and electrical components of rotating machines. It is shown that the functionality of the diagnostics systems can be expanded with minimal changes in technological chains of repair and operation of rotating machinery. Automation of such systems reduces the influence of the human factor on the quality of repair and diagnostics of the machinery.

  9. Evaluation of an Automated System for Reading and Interpreting Disk Diffusion Antimicrobial Susceptibility Testing of Fastidious Bacteria.

    Science.gov (United States)

    Idelevich, Evgeny A; Becker, Karsten; Schmitz, Janne; Knaack, Dennis; Peters, Georg; Köck, Robin

    2016-01-01

    Results of disk diffusion antimicrobial susceptibility testing depend on individual visual reading of inhibition zone diameters. Therefore, automated reading using camera systems might represent a useful tool for standardization. In this study, the ADAGIO automated system (Bio-Rad) was evaluated for reading disk diffusion tests of fastidious bacteria. 144 clinical isolates (68 β-haemolytic streptococci, 28 Streptococcus pneumoniae, 18 viridans group streptococci, 13 Haemophilus influenzae, 7 Moraxella catarrhalis, and 10 Campylobacter jejuni) were tested on Mueller-Hinton agar supplemented with 5% defibrinated horse blood and 20 mg/L β-NAD (MH-F, Oxoid) according to EUCAST. Plates were read manually with a ruler and automatically using the ADAGIO system. Inhibition zone diameters, indicated by the automated system, were visually controlled and adjusted, if necessary. Among 1548 isolate-antibiotic combinations, comparison of automated vs. manual reading yielded categorical agreement (CA) without visual adjustment of the automatically determined zone diameters in 81.4%. In 20% (309 of 1548) of tests it was deemed necessary to adjust the automatically determined zone diameter after visual control. After adjustment, CA was 94.8%; very major errors (false susceptible interpretation), major errors (false resistant interpretation) and minor errors (false categorization involving intermediate result), calculated according to the ISO 20776-2 guideline, accounted to 13.7% (13 of 95 resistant results), 3.3% (47 of 1424 susceptible results) and 1.4% (21 of 1548 total results), respectively, compared to manual reading. The ADAGIO system allowed for automated reading of disk diffusion testing in fastidious bacteria and, after visual validation of the automated results, yielded good categorical agreement with manual reading.

  10. Automated testing of arrhythmia monitors using annotated databases.

    Science.gov (United States)

    Elghazzawi, Z; Murray, W; Porter, M; Ezekiel, E; Goodall, M; Staats, S; Geheb, F

    1992-01-01

    Arrhythmia-algorithm performance is typically tested using the AHA and MIT/BIH databases. The tools for this test are simulation software programs. While these simulations provide rapid results, they neglect hardware and software effects in the monitor. To provide a more accurate measure of performance in the actual monitor, a system has been developed for automated arrhythmia testing. The testing system incorporates an IBM-compatible personal computer, a digital-to-analog converter, an RS232 board, a patient-simulator interface to the monitor, and a multi-tasking software package for data conversion and communication with the monitor. This system "plays" patient data files into the monitor and saves beat classifications in detection files. Tests were performed using the MIT/BIH and AHA databases. Statistics were generated by comparing the detection files with the annotation files. These statistics were marginally different from those that resulted from the simulation. Differences were then examined. As expected, the differences were related to monitor hardware effects.

  11. Detection of cut-off point for rapid automized naming test in good readers and dyslexics

    Directory of Open Access Journals (Sweden)

    Zahra Soleymani

    2014-01-01

    Full Text Available Background and Aim: Rapid automized naming test is an appropriate tool to diagnose learning disability even before teaching reading. This study aimed to detect the cut-off point of this test for good readers and dyslexics.Methods: The test has 4 parts including: objects, colors, numbers and letters. 5 items are repeated on cards randomly for 10 times. Children were asked to name items rapidly. We studied 18 dyslexic students and 18 age-matched good readers between 7 and 8 years of age at second and third grades of elementary school; they were recruited by non-randomize sampling into 2 groups: children with developmental dyslexia from learning disabilities centers with mean age of 100 months, and normal children with mean age of 107 months from general schools in Tehran. Good readers selected from the same class of dyslexics.Results: The area under the receiver operating characteristic curve was 0.849 for letter naming, 0.892 for color naming, 0.971 for number naming, 0.887 for picture naming, and 0.965 totally. The overall sensitivity and specificity was 1 and was 0.79, respectively. The highest sensitivity and specificity were related to number naming (1 and 0.90, respectively.Conclusion: Findings showed that the rapid automized naming test could diagnose good readers from dyslexics appropriately.

  12. Automated cognitive testing of monkeys in social groups yields results comparable to individual laboratory-based testing.

    Science.gov (United States)

    Gazes, Regina Paxton; Brown, Emily Kathryn; Basile, Benjamin M; Hampton, Robert R

    2013-05-01

    Cognitive abilities likely evolved in response to specific environmental and social challenges and are therefore expected to be specialized for the life history of each species. Specialized cognitive abilities may be most readily engaged under conditions that approximate the natural environment of the species being studied. While naturalistic environments might therefore have advantages over laboratory settings for cognitive research, it is difficult to conduct certain types of cognitive tests in these settings. We implemented methods for automated cognitive testing of monkeys (Macaca mulatta) in large social groups (Field station) and compared the performance to that of laboratory-housed monkeys (Laboratory). The Field station animals shared access to four touch-screen computers in a large naturalistic social group. Each Field station subject had an RFID chip implanted in each arm for computerized identification and individualized assignment of cognitive tests. The Laboratory group was housed and tested in a typical laboratory setting, with individual access to testing computers in their home cages. Monkeys in both groups voluntarily participated at their own pace for food rewards. We evaluated performance in two visual psychophysics tests, a perceptual classification test, a transitive inference test, and a delayed matching-to-sample memory test. Despite the differences in housing, social environment, age, and sex, monkeys in the two groups performed similarly in all tests. Semi-free ranging monkeys living in complex social environments are therefore viable subjects for cognitive testing designed to take advantage of the unique affordances of naturalistic testing environments.

  13. High precision automated face localization in thermal images: oral cancer dataset as test case

    Science.gov (United States)

    Chakraborty, M.; Raman, S. K.; Mukhopadhyay, S.; Patsa, S.; Anjum, N.; Ray, J. G.

    2017-02-01

    Automated face detection is the pivotal step in computer vision aided facial medical diagnosis and biometrics. This paper presents an automatic, subject adaptive framework for accurate face detection in the long infrared spectrum on our database for oral cancer detection consisting of malignant, precancerous and normal subjects of varied age group. Previous works on oral cancer detection using Digital Infrared Thermal Imaging(DITI) reveals that patients and normal subjects differ significantly in their facial thermal distribution. Therefore, it is a challenging task to formulate a completely adaptive framework to veraciously localize face from such a subject specific modality. Our model consists of first extracting the most probable facial regions by minimum error thresholding followed by ingenious adaptive methods to leverage the horizontal and vertical projections of the segmented thermal image. Additionally, the model incorporates our domain knowledge of exploiting temperature difference between strategic locations of the face. To our best knowledge, this is the pioneering work on detecting faces in thermal facial images comprising both patients and normal subjects. Previous works on face detection have not specifically targeted automated medical diagnosis; face bounding box returned by those algorithms are thus loose and not apt for further medical automation. Our algorithm significantly outperforms contemporary face detection algorithms in terms of commonly used metrics for evaluating face detection accuracy. Since our method has been tested on challenging dataset consisting of both patients and normal subjects of diverse age groups, it can be seamlessly adapted in any DITI guided facial healthcare or biometric applications.

  14. THE METHOD OF FORMING THE PIGGYBACK TECHNOLOGIES USING THE AUTOMATED HEURISTIC SYSTEM

    Directory of Open Access Journals (Sweden)

    Ye. Nahornyi

    2015-07-01

    Full Text Available In order to choose a rational piggyback technology there was offered a method that envisages the automated system improvement by giving it a heuristic nature. The automated system is based on a set of methods, techniques and strategies aimed at creating optimal resource saving technologies, which makes it possible to take into account with maximum efficiency the interests of all the participants of the delivery process. When organizing the piggyback traffic there is presupposed the coordination of operations between the piggyback traffic participants to minimize the cargo travel time.

  15. Development and evaluation of an automated system for testing current meters

    Directory of Open Access Journals (Sweden)

    Ezequiel Saretta

    2016-02-01

    Full Text Available ABSTRACT Current meters are equipment widely used for estimating flow velocity in rivers and streams. Periodic calibrations of current meters are important to ensure the quality of measurements, but the required testing facilities are complex and only available in a few institutions. However, advances in electronics and automation may contribute to developing simple and reliable calibration systems. Thus, this study aimed to develop an automated system for testing current meters, which consisted of a trapezoidal channel, a step motor, a tow car and a management system, composed of a supervisory application and microprocessed modules to control the motor and the data acquisition. Evaluations of the displacement velocity showed that it matched the reference value up to 1.85 m s-1 for a vertical-axis current meter and 2.3 m s-1 for a horizontal-axis one. The developed system showed reliability during tests, for both current meter movement and data acquisition. The management of the system based on the developed modules and the supervisory application improved its user interface, turning all the procedure into a simple task.

  16. Automated Testing Infrastructure and Result Comparison for Geodynamics Codes

    Science.gov (United States)

    Heien, E. M.; Kellogg, L. H.

    2013-12-01

    The geodynamics community uses a wide variety of codes on a wide variety of both software and hardware platforms to simulate geophysical phenomenon. These codes are generally variants of finite difference or finite element calculations involving Stokes flow or wave propagation. A significant problem is that codes of even low complexity will return different results depending on the platform due to slight differences in hardware, software, compiler, and libraries. Furthermore, changes to the codes during development may affect solutions in unexpected ways such that previously validated results are altered. The Computational Infrastructure for Geodynamics (CIG) is funded by the NSF to enhance the capabilities of the geodynamics community through software development. CIG has recently done extensive work in setting up an automated testing and result validation system based on the BaTLab system developed at the University of Wisconsin, Madison. This system uses 16 variants of Linux and Mac platforms on both 32 and 64-bit processors to test several CIG codes, and has also recently been extended to support testing on the XSEDE TACC (Texas Advanced Computing Center) Stampede cluster. In this work we overview the system design and demonstrate how automated testing and validation occurs and results are reported. We also examine several results from the system from different codes and discuss how changes in compilers and libraries affect the results. Finally we detail some result comparison tools for different types of output (scalar fields, velocity fields, seismogram data), and discuss within what margins different results can be considered equivalent.

  17. Frameworks for Performing on Cloud Automated Software Testing Using Swarm Intelligence Algorithm: Brief Survey

    Directory of Open Access Journals (Sweden)

    Mohammad Hossain

    2018-04-01

    Full Text Available This paper surveys on Cloud Based Automated Testing Software that is able to perform Black-box testing, White-box testing, as well as Unit and Integration Testing as a whole. In this paper, we discuss few of the available automated software testing frameworks on the cloud. These frameworks are found to be more efficient and cost effective because they execute test suites over a distributed cloud infrastructure. One of the framework effectiveness was attributed to having a module that accepts manual test cases from users and it prioritize them accordingly. Software testing, in general, accounts for as much as 50% of the total efforts of the software development project. To lessen the efforts, one the frameworks discussed in this paper used swarm intelligence algorithms. It uses the Ant Colony Algorithm for complete path coverage to minimize time and the Bee Colony Optimization (BCO for regression testing to ensure backward compatibility.

  18. [A study of biomechanical method for urine test based on color difference estimation].

    Science.gov (United States)

    Wang, Chunhong; Zhou, Yue; Zhao, Hongxia; Zhou, Fengkun

    2008-02-01

    The biochemical analysis of urine is an important inspection and diagnosis method in hospitals. The conventional method of urine analysis covers mainly colorimetric visual appraisement and automation detection, in which the colorimetric visual appraisement technique has been superseded basically, and the automation detection method is adopted in hospital; moreover, the price of urine biochemical analyzer on market is around twenty thousand RMB yuan (Y), which is hard to enter into ordinary families. It is known that computer vision system is not subject to the physiological and psychological influence of person, its appraisement standard is objective and steady. Therefore, according to the color theory, we have established a computer vision system, which can carry through collection, management, display, and appraisement of color difference between the color of standard threshold value and the color of urine test paper after reaction with urine liquid, and then the level of an illness can be judged accurately. In this paper, we introduce the Urine Test Biochemical Analysis method, which is new and can be popularized in families. Experimental result shows that this test method is easy-to-use and cost-effective. It can realize the monitoring of a whole course and can find extensive applications.

  19. Automated Model Fit Method for Diesel Engine Control Development

    NARCIS (Netherlands)

    Seykens, X.; Willems, F.P.T.; Kuijpers, B.; Rietjens, C.

    2014-01-01

    This paper presents an automated fit for a control-oriented physics-based diesel engine combustion model. This method is based on the combination of a dedicated measurement procedure and structured approach to fit the required combustion model parameters. Only a data set is required that is

  20. Automated model fit method for diesel engine control development

    NARCIS (Netherlands)

    Seykens, X.L.J.; Willems, F.P.T.; Kuijpers, B.; Rietjens, C.J.H.

    2014-01-01

    This paper presents an automated fit for a control-oriented physics-based diesel engine combustion model. This method is based on the combination of a dedicated measurement procedure and structured approach to fit the required combustion model parameters. Only a data set is required that is

  1. Simple heuristics: A bridge between manual core design and automated optimization methods

    International Nuclear Information System (INIS)

    White, J.R.; Delmolino, P.M.

    1993-01-01

    The primary function of RESCUE is to serve as an aid in the analysis and identification of feasible loading patterns for LWR reload cores. The unique feature of RESCUE is that its physics model is based on some recent advances in generalized perturbation theory (GPT) methods. The high order GPT techniques offer the accuracy, computational efficiency, and flexibility needed for the implementation of a full range of capabilities within a set of compatible interactive (manual and semi-automated) and automated design tools. The basic design philosophy and current features within RESCUE are reviewed, and the new semi-automated capability is highlighted. The online advisor facility appears quite promising and it provides a natural bridge between the traditional trial-and-error manual process and the recent progress towards fully automated optimization sequences. (orig.)

  2. Standard Test Method for Application and Analysis of Solid State Track Recorder (SSTR) Monitors for Reactor Surveillance, E706(IIIB)

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2003-01-01

    1.1 This test method describes the use of solid-state track recorders (SSTRs) for neutron dosimetry in light-water reactor (LWR) applications. These applications extend from low neutron fluence to high neutron fluence, including high power pressure vessel surveillance and test reactor irradiations as well as low power benchmark field measurement. (1) This test method replaces Method E 418. This test method is more detailed and special attention is given to the use of state-of-the-art manual and automated track counting methods to attain high absolute accuracies. In-situ dosimetry in actual high fluence-high temperature LWR applications is emphasized. 1.2 This test method includes SSTR analysis by both manual and automated methods. To attain a desired accuracy, the track scanning method selected places limits on the allowable track density. Typically good results are obtained in the range of 5 to 800 000 tracks/cm2 and accurate results at higher track densities have been demonstrated for some cases. (2) Trac...

  3. Comparison of subjective and fully automated methods for measuring mammographic density.

    Science.gov (United States)

    Moshina, Nataliia; Roman, Marta; Sebuødegård, Sofie; Waade, Gunvor G; Ursin, Giske; Hofvind, Solveig

    2018-02-01

    Background Breast radiologists of the Norwegian Breast Cancer Screening Program subjectively classified mammographic density using a three-point scale between 1996 and 2012 and changed into the fourth edition of the BI-RADS classification since 2013. In 2015, an automated volumetric breast density assessment software was installed at two screening units. Purpose To compare volumetric breast density measurements from the automated method with two subjective methods: the three-point scale and the BI-RADS density classification. Material and Methods Information on subjective and automated density assessment was obtained from screening examinations of 3635 women recalled for further assessment due to positive screening mammography between 2007 and 2015. The score of the three-point scale (I = fatty; II = medium dense; III = dense) was available for 2310 women. The BI-RADS density score was provided for 1325 women. Mean volumetric breast density was estimated for each category of the subjective classifications. The automated software assigned volumetric breast density to four categories. The agreement between BI-RADS and volumetric breast density categories was assessed using weighted kappa (k w ). Results Mean volumetric breast density was 4.5%, 7.5%, and 13.4% for categories I, II, and III of the three-point scale, respectively, and 4.4%, 7.5%, 9.9%, and 13.9% for the BI-RADS density categories, respectively ( P for trend density categories was k w  = 0.5 (95% CI = 0.47-0.53; P density increased with increasing density category of the subjective classifications. The agreement between BI-RADS and volumetric breast density categories was moderate.

  4. Engineering systems for novel automation methods

    International Nuclear Information System (INIS)

    Fischer, H.D.

    1997-01-01

    Modern automation methods of Optimal Control, or for state reconstruction or parameter identification, require a discrete dynamic path model. This is established among others by time and location discretisation of a system of partial differential equations. The digital wave filter principle is paricularly suitable for this purpose, since the numeric stability of the derived algorithms can be easily guaranteed, and their robustness as to effects of word length limitations can be proven. This principle is also particularly attractive in that it can be excellently integrated into currently existing engineering systems for instrumentation and control. (orig./CB) [de

  5. The Center-TRACON Automation System: Simulation and field testing

    Science.gov (United States)

    Denery, Dallas G.; Erzberger, Heinz

    1995-01-01

    A new concept for air traffic management in the terminal area, implemented as the Center-TRACON Automation System, has been under development at NASA Ames in a cooperative program with the FAA since 1991. The development has been strongly influenced by concurrent simulation and field site evaluations. The role of simulation and field activities in the development process will be discussed. Results of recent simulation and field tests will be presented.

  6. Simulation and Automation of the EEBI Test at ALS

    CERN Document Server

    Nishimura, Hiroshi

    2005-01-01

    The Errant Electron Beam Interlock (EEBI) is a system that protects the vacuum chamber of the Advanced Light Source (ALS) from synchrotron light damage should the orbit, through a superconducting bend magnet (superbend), become distorted. The EEBI system monitors the vertical beam position on two BPMs, one upstream and the other downstream, of the superbend and dumps the stored beam if the orbit exceeds preset limits in either offset or angle. Discussed are the modeling studies carried out to determine how to create a large vertical bump, both for performing the test and implementing the automated test software.

  7. Automated systems help prevent operator error during [reactor] I and C [instrumentation and control] testing

    International Nuclear Information System (INIS)

    Courcoux, R.

    1989-01-01

    On a nuclear steam supply system, even a minor failure can involve actuation of the whole reactor protection system (RPS). To reduce the likelihood of human error leading to unwanted trips during the maintenance of instrumentation and control systems, Framatome has been developing and installing various automated testing systems. Such automated systems are particularly helpful when periodic tests with a potential for RPS actuation have to be carried out, or when the test is on the critical path for the refuelling outage. The Sensitive Channel Programme described is an example of the sort of work that has been done. (author)

  8. A Novel Automated Method for Analyzing Cylindrical Computed Tomography Data

    Science.gov (United States)

    Roth, D. J.; Burke, E. R.; Rauser, R. W.; Martin, R. E.

    2011-01-01

    A novel software method is presented that is applicable for analyzing cylindrical and partially cylindrical objects inspected using computed tomography. This method involves unwrapping and re-slicing data so that the CT data from the cylindrical object can be viewed as a series of 2-D sheets in the vertical direction in addition to volume rendering and normal plane views provided by traditional CT software. The method is based on interior and exterior surface edge detection and under proper conditions, is FULLY AUTOMATED and requires no input from the user except the correct voxel dimension from the CT scan. The software is available from NASA in 32- and 64-bit versions that can be applied to gigabyte-sized data sets, processing data either in random access memory or primarily on the computer hard drive. Please inquire with the presenting author if further interested. This software differentiates itself in total from other possible re-slicing software solutions due to complete automation and advanced processing and analysis capabilities.

  9. Automated general temperature correction method for dielectric soil moisture sensors

    Science.gov (United States)

    Kapilaratne, R. G. C. Jeewantinie; Lu, Minjiao

    2017-08-01

    An effective temperature correction method for dielectric sensors is important to ensure the accuracy of soil water content (SWC) measurements of local to regional-scale soil moisture monitoring networks. These networks are extensively using highly temperature sensitive dielectric sensors due to their low cost, ease of use and less power consumption. Yet there is no general temperature correction method for dielectric sensors, instead sensor or site dependent correction algorithms are employed. Such methods become ineffective at soil moisture monitoring networks with different sensor setups and those that cover diverse climatic conditions and soil types. This study attempted to develop a general temperature correction method for dielectric sensors which can be commonly used regardless of the differences in sensor type, climatic conditions and soil type without rainfall data. In this work an automated general temperature correction method was developed by adopting previously developed temperature correction algorithms using time domain reflectometry (TDR) measurements to ThetaProbe ML2X, Stevens Hydra probe II and Decagon Devices EC-TM sensor measurements. The rainy day effects removal procedure from SWC data was automated by incorporating a statistical inference technique with temperature correction algorithms. The temperature correction method was evaluated using 34 stations from the International Soil Moisture Monitoring Network and another nine stations from a local soil moisture monitoring network in Mongolia. Soil moisture monitoring networks used in this study cover four major climates and six major soil types. Results indicated that the automated temperature correction algorithms developed in this study can eliminate temperature effects from dielectric sensor measurements successfully even without on-site rainfall data. Furthermore, it has been found that actual daily average of SWC has been changed due to temperature effects of dielectric sensors with a

  10. A method to establish seismic noise baselines for automated station assessment

    Science.gov (United States)

    McNamara, D.E.; Hutt, C.R.; Gee, L.S.; Benz, H.M.; Buland, R.P.

    2009-01-01

    We present a method for quantifying station noise baselines and characterizing the spectral shape of out-of-nominal noise sources. Our intent is to automate this method in order to ensure that only the highest-quality data are used in rapid earthquake products at NEIC. In addition, the station noise baselines provide a valuable tool to support the quality control of GSN and ANSS backbone data and metadata. The procedures addressed here are currently in development at the NEIC, and work is underway to understand how quickly changes from nominal can be observed and used within the NEIC processing framework. The spectral methods and software used to compute station baselines and described herein (PQLX) can be useful to both permanent and portable seismic stations operators. Applications include: general seismic station and data quality control (QC), evaluation of instrument responses, assessment of near real-time communication system performance, characterization of site cultural noise conditions, and evaluation of sensor vault design, as well as assessment of gross network capabilities (McNamara et al. 2005). Future PQLX development plans include incorporating station baselines for automated QC methods and automating station status report generation and notification based on user-defined QC parameters. The PQLX software is available through the USGS (http://earthquake. usgs.gov/research/software/pqlx.php) and IRIS (http://www.iris.edu/software/ pqlx/).

  11. Process automation

    International Nuclear Information System (INIS)

    Moser, D.R.

    1986-01-01

    Process automation technology has been pursued in the chemical processing industries and to a very limited extent in nuclear fuel reprocessing. Its effective use has been restricted in the past by the lack of diverse and reliable process instrumentation and the unavailability of sophisticated software designed for process control. The Integrated Equipment Test (IET) facility was developed by the Consolidated Fuel Reprocessing Program (CFRP) in part to demonstrate new concepts for control of advanced nuclear fuel reprocessing plants. A demonstration of fuel reprocessing equipment automation using advanced instrumentation and a modern, microprocessor-based control system is nearing completion in the facility. This facility provides for the synergistic testing of all chemical process features of a prototypical fuel reprocessing plant that can be attained with unirradiated uranium-bearing feed materials. The unique equipment and mission of the IET facility make it an ideal test bed for automation studies. This effort will provide for the demonstration of the plant automation concept and for the development of techniques for similar applications in a full-scale plant. A set of preliminary recommendations for implementing process automation has been compiled. Some of these concepts are not generally recognized or accepted. The automation work now under way in the IET facility should be useful to others in helping avoid costly mistakes because of the underutilization or misapplication of process automation. 6 figs

  12. Project TwEATs: a feasibility study testing the use of automated text messaging to monitor appetite ratings in a free-living population

    Science.gov (United States)

    Schembre, Susan M.; Yuen, Jessica

    2011-01-01

    There are no standardized methods for monitoring appetite in free-living populations. Fifteen participants tested a computer-automated text-messaging system designed to track hunger ratings over seven days. Participants were sent text-messages (SMS) hourly and instructed to reply during waking hours with their current hunger rating. Of 168 SMS, 0.6-7.1% were undelivered, varying by mobile service provider, On average 12 SMS responses were received daily with minor variations by observation day or day of the week. Compliance was over 74% and 93% of the ratings were received within 30-minutes. Automated text-messaging is a feasible method to monitor appetite ratings in this population. PMID:21251941

  13. 76 FR 69755 - National Customs Automation Program Test Concerning Automated Commercial Environment (ACE...

    Science.gov (United States)

    2011-11-09

    ... DEPARTMENT OF HOMELAND SECURITY U.S. Customs and Border Protection National Customs Automation... announces U.S. Customs and Border Protection's (CBP's) plan to conduct a National Customs Automation Program... conveyance transporting the cargo to the United States. This data will fulfill merchandise entry requirements...

  14. Diversity and testing requirements of programmable automation systems; Ohjelmoitavan automaation diversiteetti- ja testausvaatimukset

    Energy Technology Data Exchange (ETDEWEB)

    Haapanen, P.; Maskuniitty, M.

    1993-04-01

    In the report programmable digital operation and safety automation systems for nuclear power plants are discussed. The programmable systems deviate by their properties and behaviour from the conventional non-programmable systems in such extent, that their verification and validation for safety critical applications requires new methods and practices. The safety assessment can not be based on conventional probabilistic methods due to the difficulties in the quantification of the reliability of the software and hardware. A safety critical programmable system shall include diverse redundant parts so that no residual program fault can not cause the failure of the intended function of the system. Although complete testing of a programmable system is impossible, different tests have a central role in the production and validation process of the system. Diversity is important also in confidence building measures for the implemented system. Independent analysis and testing of the system should use different methods and tools from those used in the production and validation process by the system vendor. Use of diversity and testing are concluded to be central issues in producing safe programmable system and in proving them to be safe enough. By combining functional and programming diversity in a suitable way one can produce a system that is safe enough without having a non-programmable back-up system. (48 refs., 10 figs., 2 tabs.).

  15. Method for semi-automated microscopy of filtration-enriched circulating tumor cells.

    Science.gov (United States)

    Pailler, Emma; Oulhen, Marianne; Billiot, Fanny; Galland, Alexandre; Auger, Nathalie; Faugeroux, Vincent; Laplace-Builhé, Corinne; Besse, Benjamin; Loriot, Yohann; Ngo-Camus, Maud; Hemanda, Merouan; Lindsay, Colin R; Soria, Jean-Charles; Vielh, Philippe; Farace, Françoise

    2016-07-14

    Circulating tumor cell (CTC)-filtration methods capture high numbers of CTCs in non-small-cell lung cancer (NSCLC) and metastatic prostate cancer (mPCa) patients, and hold promise as a non-invasive technique for treatment selection and disease monitoring. However filters have drawbacks that make the automation of microscopy challenging. We report the semi-automated microscopy method we developed to analyze filtration-enriched CTCs from NSCLC and mPCa patients. Spiked cell lines in normal blood and CTCs were enriched by ISET (isolation by size of epithelial tumor cells). Fluorescent staining was carried out using epithelial (pan-cytokeratins, EpCAM), mesenchymal (vimentin, N-cadherin), leukocyte (CD45) markers and DAPI. Cytomorphological staining was carried out with Mayer-Hemalun or Diff-Quik. ALK-, ROS1-, ERG-rearrangement were detected by filter-adapted-FISH (FA-FISH). Microscopy was carried out using an Ariol scanner. Two combined assays were developed. The first assay sequentially combined four-color fluorescent staining, scanning, automated selection of CD45(-) cells, cytomorphological staining, then scanning and analysis of CD45(-) cell phenotypical and cytomorphological characteristics. CD45(-) cell selection was based on DAPI and CD45 intensity, and a nuclear area >55 μm(2). The second assay sequentially combined fluorescent staining, automated selection of CD45(-) cells, FISH scanning on CD45(-) cells, then analysis of CD45(-) cell FISH signals. Specific scanning parameters were developed to deal with the uneven surface of filters and CTC characteristics. Thirty z-stacks spaced 0.6 μm apart were defined as the optimal setting, scanning 82 %, 91 %, and 95 % of CTCs in ALK-, ROS1-, and ERG-rearranged patients respectively. A multi-exposure protocol consisting of three separate exposure times for green and red fluorochromes was optimized to analyze the intensity, size and thickness of FISH signals. The semi-automated microscopy method reported here

  16. Assessment selection in human-automation interaction studies: The Failure-GAM2E and review of assessment methods for highly automated driving.

    Science.gov (United States)

    Grane, Camilla

    2018-01-01

    Highly automated driving will change driver's behavioural patterns. Traditional methods used for assessing manual driving will only be applicable for the parts of human-automation interaction where the driver intervenes such as in hand-over and take-over situations. Therefore, driver behaviour assessment will need to adapt to the new driving scenarios. This paper aims at simplifying the process of selecting appropriate assessment methods. Thirty-five papers were reviewed to examine potential and relevant methods. The review showed that many studies still relies on traditional driving assessment methods. A new method, the Failure-GAM 2 E model, with purpose to aid assessment selection when planning a study, is proposed and exemplified in the paper. Failure-GAM 2 E includes a systematic step-by-step procedure defining the situation, failures (Failure), goals (G), actions (A), subjective methods (M), objective methods (M) and equipment (E). The use of Failure-GAM 2 E in a study example resulted in a well-reasoned assessment plan, a new way of measuring trust through feet movements and a proposed Optimal Risk Management Model. Failure-GAM 2 E and the Optimal Risk Management Model are believed to support the planning process for research studies in the field of human-automation interaction. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Conventional cable testing methods: strengths, weaknesses and possibilities

    International Nuclear Information System (INIS)

    Reynolds, P.H.

    1988-01-01

    The paper reviews the major conventional methods that can be used to test power plant cables. It assesses their usefulness in diagnosing the condition of the insulation of the cable and then proposes some possible directions for innovation. The methods examined are dc insulation resistance measurement, ac signal injection for continuous monitoring and fault location, and the ac measurement of capacitance and loss angle. Specific subjects considered are the effects of temperature, cable construction and installation, and the validity of insulation resistance or loss angle measurement. The innovative proposals refer to the use of automation in the measurement and of computer-based Expert Systems for the evaluation of the results

  18. LHCb - Automated Testing Infrastructure for the Software Framework Gaudi

    CERN Multimedia

    Clemencic, M

    2009-01-01

    An extensive test suite is the first step towards the delivery of robust software, but it is not always easy to implement it, especially in projects with many developers. An easy to use and flexible infrastructure to use to write and execute the tests reduces the work each developer has to do to instrument his packages with tests. At the same time, the infrastructure gives the same look and feel to the tests and allows automated execution of the test suite. For Gaudi, we decided to develop the testing infrastructure on top of the free tool QMTest, used already in LCG Application Area for the routine tests run in the nightly build system. The high flexibility of QMTest allowed us to integrate it in the Gaudi package structure. A specialized test class and some utility functions have been developed to simplify the definition of a test for a Gaudi-based application. Thanks to the testing infrastructure described here, we managed to quickly extend the standard Gaudi test suite and add tests to the main LHCb appli...

  19. Automation of ALK gene rearrangement testing with fluorescence in situ hybridization (FISH): a feasibility study.

    Science.gov (United States)

    Zwaenepoel, Karen; Merkle, Dennis; Cabillic, Florian; Berg, Erica; Belaud-Rotureau, Marc-Antoine; Grazioli, Vittorio; Herelle, Olga; Hummel, Michael; Le Calve, Michele; Lenze, Dido; Mende, Stefanie; Pauwels, Patrick; Quilichini, Benoit; Repetti, Elena

    2015-02-01

    In the past several years we have observed a significant increase in our understanding of molecular mechanisms that drive lung cancer. Specifically in the non-small cell lung cancer sub-types, ALK gene rearrangements represent a sub-group of tumors that are targetable by the tyrosine kinase inhibitor Crizotinib, resulting in significant reductions in tumor burden. Phase II and III clinical trials were performed using an ALK break-apart FISH probe kit, making FISH the gold standard for identifying ALK rearrangements in patients. FISH is often considered a labor and cost intensive molecular technique, and in this study we aimed to demonstrate feasibility for automation of ALK FISH testing, to improve laboratory workflow and ease of testing. This involved automation of the pre-treatment steps of the ALK assay using various protocols on the VP 2000 instrument, and facilitating automated scanning of the fluorescent FISH specimens for simplified enumeration on various backend scanning and analysis systems. The results indicated that ALK FISH can be automated. Significantly, both the Ikoniscope and BioView system of automated FISH scanning and analysis systems provided a robust analysis algorithm to define ALK rearrangements. In addition, the BioView system facilitated consultation of difficult cases via the internet. Copyright © 2015 Elsevier Inc. All rights reserved.

  20. Development of a robotics system for automated chemical analysis of sediments, sludges, and soils

    International Nuclear Information System (INIS)

    McGrail, B.P.; Dodson, M.G.; Skorpik, J.R.; Strachan, D.M.; Barich, J.J.

    1989-01-01

    Adaptation and use of a high-reliability robot to conduct a standard laboratory procedure for soil chemical analysis are reported. Results from a blind comparative test were used to obtain a quantitative measure of the improvement in precision possible with the automated test method. Results from the automated chemical analysis procedure were compared with values obtained from an EPA-certified lab and with results from a more extensive interlaboratory round robin conducted by the EPA. For several elements, up to fivefold improvement in precision was obtained with the automated test method

  1. Testing of an automated online EA-IRMS method for fast and simultaneous carbon content and stable isotope measurement of aerosol samples

    Science.gov (United States)

    Major, István; Gyökös, Brigitta; Túri, Marianna; Futó, István; Filep, Ágnes; Hoffer, András; Molnár, Mihály

    2016-04-01

    Comprehensive atmospheric studies have demonstrated that carbonaceous aerosol is one of the main components of atmospheric particulate matter over Europe. Various methods, considering optical or thermal properties, have been developed for quantification of the accurate amount of both organic and elemental carbon constituents of atmospheric aerosol. The aim of our work was to develop an alternative fast and easy method for determination of the total carbon content of individual aerosol samples collected on prebaked quartz filters whereby the mass and surface concentration becomes simply computable. We applied the conventional "elemental analyzer (EA) coupled online with an isotope ratio mass spectrometer (IRMS)" technique which is ubiquitously used in mass spectrometry. Using this technique we are able to measure simultaneously the carbon stable isotope ratio of the samples, as well. During the developing process, we compared the EA-IRMS technique with an off-line catalytic combustion method worked out previously at Hertelendi Laboratory of Environmental Studies (HEKAL). We tested the combined online total carbon content and stable isotope ratio measurement both on standard materials and real aerosol samples. Regarding the test results the novel method assures, on the one hand, at least 95% of carbon recovery yield in a broad total carbon mass range (between 100 and 3000 ug) and, on the other hand, a good reproducibility of stable isotope measurements with an uncertainty of ± 0.2 per mill. Comparing the total carbon results obtained by the EA-IRMS and the off-line catalytic combustion method we found a very good correlation (R2=0.94) that proves the applicability of both preparation method. Advantages of the novel method are the fast and simplified sample preparation steps and the fully automated, simultaneous carbon stable isotope ratio measurement processes. Furthermore stable isotope ratio results can effectively be applied in the source apportionment

  2. SlugIn 1.0: A Free Tool for Automated Slug Test Analysis.

    Science.gov (United States)

    Martos-Rosillo, Sergio; Guardiola-Albert, Carolina; Padilla Benítez, Alberto; Delgado Pastor, Joaquín; Azcón González, Antonio; Durán Valsero, Juan José

    2018-05-01

    The correct characterization of aquifer parameters is essential for water-supply and water-quality investigations. Slug tests are widely used for these purposes. While free software is available to interpret slug tests, some codes are not user-friendly, or do not include a wide range of methods to interpret the results, or do not include automatic, inverse solutions to the test data. The private sector has also generated several good programs to interpret slug test data, but they are not free of charge. The computer program SlugIn 1.0 is available online for free download, and is demonstrated to aid in the analysis of slug tests to estimate hydraulic parameters. The program provides an easy-to-use Graphical User Interface. SlugIn 1.0 incorporates automated parameter estimation and facilitates the visualization of several interpretations of the same test. It incorporates solutions for confined and unconfined aquifers, partially penetrating wells, skin effects, shape factor, anisotropy, high hydraulic conductivity formations and the Mace test for large-diameter wells. It is available in English and Spanish and can be downloaded from the web site of the Geological Survey of Spain. Two field examples are presented to illustrate how the software operates. © 2018, National Ground Water Association.

  3. Plant automation

    International Nuclear Information System (INIS)

    Christensen, L.J.; Sackett, J.I.; Dayal, Y.; Wagner, W.K.

    1989-01-01

    This paper describes work at EBR-II in the development and demonstration of new control equipment and methods and associated schemes for plant prognosis, diagnosis, and automation. The development work has attracted the interest of other national laboratories, universities, and commercial companies. New initiatives include use of new control strategies, expert systems, advanced diagnostics, and operator displays. The unique opportunity offered by EBR-II is as a test bed where a total integrated approach to automatic reactor control can be directly tested under real power plant conditions

  4. Automation of ultrasonic testing, instrumentation and rules for application and evaluation. Proceedings; Automatisierung der Ultraschallpruefung, Geraetetechnik und Regeln zur Anwendung und Auswertung. Vortraege des Seminars

    Energy Technology Data Exchange (ETDEWEB)

    Wuestenberg, H. [comp.

    1997-12-31

    The proceedings volume contains 18 lectures of the seminar addressing the following (selected) aspects: Requirements to be met by PC cards for US testing applications, defined by producers and appliers; digital technology and its impact on multichannel US testing instruments; the ALOK and array systems combined into one very efficient testing system (SAPHIR); a testing system combining US radiation source arrays and the pulsed eddy current method by means of highly integrated microelectronics (ASICs); regulatory standards and specifications for automated US testing; requirements for automated US testing in compliance with nuclear engineering codes; state of the art in standardisation for definition of required properties of US testing systems; critical review of the proposed standard relating to the TOFD method; automated evaluation shown with the example of US testing of pipelines. (orig./CB) [Deutsch] Dieser Band enthaelt 18 Vortraege mit folgenden Themen (Auswahl): Anforderungen an Ultraschall-PC-Karten aus der Sicht von Hersteller und Betreiber; Einfluss der Digitaltechnik auf Mehrkanal-Ultraschall-Pruefanlagen; Vereinigung der ALOK- und der Gruppenstrahler-Technik in einem leistungsfaehigen Pruefsystem (SAPHIR); Ein kombiniertes Pruefsystem fuer die Ultraschall-Gruppenstrahler- und Impuls-Wirbelstrom-Technik auf der Basis von hochintegrierter Mikroelektronik (ASICs); Regelwerke und Spezifikationen fuer die automatisierte Ultraschallpruefung; Anforderungen der kerntechnischen Regelwerke an die automatisierte Ultraschallpruefung; Stand der Normung bei der Charakterisierung der Eigenschaften von Ultraschall-Pruefsystemen; Kritische Bewertung des Normungsvorschlages zur Beugungslaufzeittechnik (TOFD); und Automatisierte Auswertung am Beispiel der Ultraschallpruefung von Fernrohrleitungen. (orig.)

  5. A multi-atlas based method for automated anatomical Macaca fascicularis brain MRI segmentation and PET kinetic extraction.

    Science.gov (United States)

    Ballanger, Bénédicte; Tremblay, Léon; Sgambato-Faure, Véronique; Beaudoin-Gobert, Maude; Lavenne, Franck; Le Bars, Didier; Costes, Nicolas

    2013-08-15

    MRI templates and digital atlases are needed for automated and reproducible quantitative analysis of non-human primate PET studies. Segmenting brain images via multiple atlases outperforms single-atlas labelling in humans. We present a set of atlases manually delineated on brain MRI scans of the monkey Macaca fascicularis. We use this multi-atlas dataset to evaluate two automated methods in terms of accuracy, robustness and reliability in segmenting brain structures on MRI and extracting regional PET measures. Twelve individual Macaca fascicularis high-resolution 3DT1 MR images were acquired. Four individual atlases were created by manually drawing 42 anatomical structures, including cortical and sub-cortical structures, white matter regions, and ventricles. To create the MRI template, we first chose one MRI to define a reference space, and then performed a two-step iterative procedure: affine registration of individual MRIs to the reference MRI, followed by averaging of the twelve resampled MRIs. Automated segmentation in native space was obtained in two ways: 1) Maximum probability atlases were created by decision fusion of two to four individual atlases in the reference space, and transformation back into the individual native space (MAXPROB)(.) 2) One to four individual atlases were registered directly to the individual native space, and combined by decision fusion (PROPAG). Accuracy was evaluated by computing the Dice similarity index and the volume difference. The robustness and reproducibility of PET regional measurements obtained via automated segmentation was evaluated on four co-registered MRI/PET datasets, which included test-retest data. Dice indices were always over 0.7 and reached maximal values of 0.9 for PROPAG with all four individual atlases. There was no significant mean volume bias. The standard deviation of the bias decreased significantly when increasing the number of individual atlases. MAXPROB performed better when increasing the number of

  6. Advanced fighter technology integration (AFTI)/F-16 Automated Maneuvering Attack System final flight test results

    Science.gov (United States)

    Dowden, Donald J.; Bessette, Denis E.

    1987-01-01

    The AFTI F-16 Automated Maneuvering Attack System has undergone developmental and demonstration flight testing over a total of 347.3 flying hours in 237 sorties. The emphasis of this phase of the flight test program was on the development of automated guidance and control systems for air-to-air and air-to-ground weapons delivery, using a digital flight control system, dual avionics multiplex buses, an advanced FLIR sensor with laser ranger, integrated flight/fire-control software, advanced cockpit display and controls, and modified core Multinational Stage Improvement Program avionics.

  7. Automated uncertainty analysis methods in the FRAP computer codes

    International Nuclear Information System (INIS)

    Peck, S.O.

    1980-01-01

    A user oriented, automated uncertainty analysis capability has been incorporated in the Fuel Rod Analysis Program (FRAP) computer codes. The FRAP codes have been developed for the analysis of Light Water Reactor fuel rod behavior during steady state (FRAPCON) and transient (FRAP-T) conditions as part of the United States Nuclear Regulatory Commission's Water Reactor Safety Research Program. The objective of uncertainty analysis of these codes is to obtain estimates of the uncertainty in computed outputs of the codes is to obtain estimates of the uncertainty in computed outputs of the codes as a function of known uncertainties in input variables. This paper presents the methods used to generate an uncertainty analysis of a large computer code, discusses the assumptions that are made, and shows techniques for testing them. An uncertainty analysis of FRAP-T calculated fuel rod behavior during a hypothetical loss-of-coolant transient is presented as an example and carried through the discussion to illustrate the various concepts

  8. Influence of Cultural, Organizational, and Automation Capability on Human Automation Trust: A Case Study of Auto-GCAS Experimental Test Pilots

    Science.gov (United States)

    Koltai, Kolina; Ho, Nhut; Masequesmay, Gina; Niedober, David; Skoog, Mark; Cacanindin, Artemio; Johnson, Walter; Lyons, Joseph

    2014-01-01

    This paper discusses a case study that examined the influence of cultural, organizational and automation capability upon human trust in, and reliance on, automation. In particular, this paper focuses on the design and application of an extended case study methodology, and on the foundational lessons revealed by it. Experimental test pilots involved in the research and development of the US Air Force's newly developed Automatic Ground Collision Avoidance System served as the context for this examination. An eclectic, multi-pronged approach was designed to conduct this case study, and proved effective in addressing the challenges associated with the case's politically sensitive and military environment. Key results indicate that the system design was in alignment with pilot culture and organizational mission, indicating the potential for appropriate trust development in operational pilots. These include the low-vulnerability/ high risk nature of the pilot profession, automation transparency and suspicion, system reputation, and the setup of and communications among organizations involved in the system development.

  9. A simple method for validation and verification of pipettes mounted on automated liquid handlers

    DEFF Research Database (Denmark)

    Stangegaard, Michael; Hansen, Anders Johannes; Frøslev, Tobias Guldberg

     We have implemented a simple method for validation and verification of the performance of pipettes mounted on automated liquid handlers as necessary for laboratories accredited under ISO 17025. An 8-step serial dilution of Orange G was prepared in quadruplicates in a flat bottom 96-well microtit...... available. In conclusion, we have set up a simple solution for the continuous validation of automated liquid handlers used for accredited work. The method is cheap, simple and easy to use for aqueous solutions but requires a spectrophotometer that can read microtiter plates....... We have implemented a simple method for validation and verification of the performance of pipettes mounted on automated liquid handlers as necessary for laboratories accredited under ISO 17025. An 8-step serial dilution of Orange G was prepared in quadruplicates in a flat bottom 96-well microtiter...

  10. Automated radiometric detection of bacteria

    International Nuclear Information System (INIS)

    Waters, J.R.

    1974-01-01

    A new radiometric method called BACTEC, used for the detection of bacteria in cultures or in supposedly sterile samples, was discussed from the standpoint of methodology, both automated and semi-automated. Some of the results obtained so far were reported and some future applications and development possibilities were described. In this new method, the test sample is incubated in a sealed vial with a liquid culture medium containing a 14 C-labeled substrate. If bacteria are present, they break down the substrate, producing 14 CO 2 which is periodically extracted from the vial as a gas and is tested for radioactivity. If this gaseous radioactivity exceeds a threshold level, it is evidence of bacterial presence and growth in the test vial. The first application was for the detection of bacteria in the blood cultures of hospital patients. Data were presented showing typical results. Also discussed were future applications, such as rapid screening for bacteria in urine industrial sterility testing and the disposal of used 14 C substrates. (Mukohata, S.)

  11. Implementation of an automated assessment system of the Winston-Lutz test based on the transformed generalized Hough; Implementacion de un sistema de evaluacion automatizada del test de Winston-Lutz basado en la transformada generalizada de Hough

    Energy Technology Data Exchange (ETDEWEB)

    Martin-Viera Cueto, J. A.; Moreno Saiz, C.; Benitez Villegas, E. M.; Fernandez Canadillas, M. J.; Caballero Lucena, E.; Cantero Carrillo, M.

    2013-07-01

    It has implemented a software tool based on the generalized Hough transform to automate the evaluation of test WL This method provides a quantitative evaluation of the test. It also eliminates the subjectivity of the evaluator which is an uncertainty of 0.3 mm. (Author)

  12. Automated Testing Experience of the Linear Aerospike SR-71 Experiment (LASRE) Controller

    Science.gov (United States)

    Larson, Richard R.

    1999-01-01

    System controllers must be fail-safe, low cost, flexible to software changes, able to output health and status words, and permit rapid retest qualification. The system controller designed and tested for the aerospike engine program was an attempt to meet these requirements. This paper describes (1) the aerospike controller design, (2) the automated simulation testing techniques, and (3) the real time monitoring data visualization structure. Controller cost was minimized by design of a single-string system that used an off-the-shelf 486 central processing unit (CPU). A linked-list architecture, with states (nodes) defined in a user-friendly state table, accomplished software changes to the controller. Proven to be fail-safe, this system reported the abort cause and automatically reverted to a safe condition for any first failure. A real time simulation and test system automated the software checkout and retest requirements. A program requirement to decode all abort causes in real time during all ground and flight tests assured the safety of flight decisions and the proper execution of mission rules. The design also included health and status words, and provided a real time analysis interpretation for all health and status data.

  13. Testing for nonrandom shape similarity between sister cells using automated shape comparison

    Science.gov (United States)

    Guo, Monica; Marshall, Wallace F.

    2009-02-01

    Several reports in the biological literature have indicated that when a living cell divides, the two daughter cells have a tendency to be mirror images of each other in terms of their overall cell shape. This phenomenon would be consistent with inheritance of spatial organization from mother cell to daughters. However the published data rely on a small number of examples that were visually chosen, raising potential concerns about inadvertent selection bias. We propose to revisit this issue using automated quantitative shape comparison methods which would have no contribution from the observer and which would allow statistical testing of similarity in large numbers of cells. In this report we describe a first order approach to the problem using rigid curve matching. Using test images, we compare a pointwise correspondence based distance metric with a chamfer matching strategy and find that the latter provides better correspondence and smaller distances between aligned curves, especially when we allow nonrigid deformation of the outlines in addition to rotation.

  14. Automated Test Assembly for Cognitive Diagnosis Models Using a Genetic Algorithm

    Science.gov (United States)

    Finkelman, Matthew; Kim, Wonsuk; Roussos, Louis A.

    2009-01-01

    Much recent psychometric literature has focused on cognitive diagnosis models (CDMs), a promising class of instruments used to measure the strengths and weaknesses of examinees. This article introduces a genetic algorithm to perform automated test assembly alongside CDMs. The algorithm is flexible in that it can be applied whether the goal is to…

  15. Data collection for the methods of in-pile materials testing

    International Nuclear Information System (INIS)

    Markina, N.V.; Rudkevich, A.V.; Lebedeva, E.E.

    1985-01-01

    Problems, relating to the creation of automated data banks intended for accumulatioon and systematization of data according to the methods of in-pile materials testing, taking into account their specific nature are discussed. The architecture of the bank, realized on the BESM-6 computer is described. The bank contains data on about 300 methods. The library of requests, which may be used by a user comprises about 20 descriptions. A new request description preparation and input take 5-20 min. The system answering time is from 30 sec to 3-4 min

  16. FMEA of manual and automated methods for commissioning a radiotherapy treatment planning system.

    Science.gov (United States)

    Wexler, Amy; Gu, Bruce; Goddu, Sreekrishna; Mutic, Maya; Yaddanapudi, Sridhar; Olsen, Lindsey; Harry, Taylor; Noel, Camille; Pawlicki, Todd; Mutic, Sasa; Cai, Bin

    2017-09-01

    To evaluate the level of risk involved in treatment planning system (TPS) commissioning using a manual test procedure, and to compare the associated process-based risk to that of an automated commissioning process (ACP) by performing an in-depth failure modes and effects analysis (FMEA). The authors collaborated to determine the potential failure modes of the TPS commissioning process using (a) approaches involving manual data measurement, modeling, and validation tests and (b) an automated process utilizing application programming interface (API) scripting, preloaded, and premodeled standard radiation beam data, digital heterogeneous phantom, and an automated commissioning test suite (ACTS). The severity (S), occurrence (O), and detectability (D) were scored for each failure mode and the risk priority numbers (RPN) were derived based on TG-100 scale. Failure modes were then analyzed and ranked based on RPN. The total number of failure modes, RPN scores and the top 10 failure modes with highest risk were described and cross-compared between the two approaches. RPN reduction analysis is also presented and used as another quantifiable metric to evaluate the proposed approach. The FMEA of a MTP resulted in 47 failure modes with an RPN ave of 161 and S ave of 6.7. The highest risk process of "Measurement Equipment Selection" resulted in an RPN max of 640. The FMEA of an ACP resulted in 36 failure modes with an RPN ave of 73 and S ave of 6.7. The highest risk process of "EPID Calibration" resulted in an RPN max of 576. An FMEA of treatment planning commissioning tests using automation and standardization via API scripting, preloaded, and pre-modeled standard beam data, and digital phantoms suggests that errors and risks may be reduced through the use of an ACP. © 2017 American Association of Physicists in Medicine.

  17. Structure of the automated uchebno-methodical complex on technical disciplines

    Directory of Open Access Journals (Sweden)

    Вячеслав Михайлович Дмитриев

    2010-12-01

    Full Text Available In article it is put and the problem of automation and information of process of training of students on the basis of the entered system-organizational forms which have received in aggregate the name of education methodical complexes on discipline dares.

  18. A semi-automated method for measuring thickness and white matter ...

    African Journals Online (AJOL)

    A semi-automated method for measuring thickness and white matter integrity of the corpus callosum. ... and interhemispheric differences. Future research will determine normal values for age and compare CC thickness with peripheral white matter volume loss in large groups of patients, using the semiautomated technique.

  19. Automating with SIMATIC S7-1500 configuring, programming and testing with STEP 7 Professional

    CERN Document Server

    Berger, Hans

    2014-01-01

    With many innovations, the SIMATIC S7-1500 programmable logic controller (PLC) sets new standards in productivity and efficiency in control technology. By its outstanding system performance and with PROFINET as the standard interface, it ensures extremely short system response times and the highest control quality with a maximum of flexibility for most demanding automation tasks. The engineering software STEP 7 Professional operates inside TIA Portal, a user interface that is designed for intuitive operation. Functionality includes all aspects of Automation: from the configuration of the controllers via the programming in the IEC languages ¿¿LAD, FBD, STL, and SCL up to the program test. In the book, the hardware components of the automation system S7-1500 are presented including the description of their configuration and parameterization. A comprehensive introduction into STEP 7 Professional illustrates the basics of programming and troubleshooting. Beginners learn the basics of automation with Simatic...

  20. Microscope image based fully automated stomata detection and pore measurement method for grapevines

    Directory of Open Access Journals (Sweden)

    Hiranya Jayakody

    2017-11-01

    Full Text Available Abstract Background Stomatal behavior in grapevines has been identified as a good indicator of the water stress level and overall health of the plant. Microscope images are often used to analyze stomatal behavior in plants. However, most of the current approaches involve manual measurement of stomatal features. The main aim of this research is to develop a fully automated stomata detection and pore measurement method for grapevines, taking microscope images as the input. The proposed approach, which employs machine learning and image processing techniques, can outperform available manual and semi-automatic methods used to identify and estimate stomatal morphological features. Results First, a cascade object detection learning algorithm is developed to correctly identify multiple stomata in a large microscopic image. Once the regions of interest which contain stomata are identified and extracted, a combination of image processing techniques are applied to estimate the pore dimensions of the stomata. The stomata detection approach was compared with an existing fully automated template matching technique and a semi-automatic maximum stable extremal regions approach, with the proposed method clearly surpassing the performance of the existing techniques with a precision of 91.68% and an F1-score of 0.85. Next, the morphological features of the detected stomata were measured. Contrary to existing approaches, the proposed image segmentation and skeletonization method allows us to estimate the pore dimensions even in cases where the stomatal pore boundary is only partially visible in the microscope image. A test conducted using 1267 images of stomata showed that the segmentation and skeletonization approach was able to correctly identify the stoma opening 86.27% of the time. Further comparisons made with manually traced stoma openings indicated that the proposed method is able to estimate stomata morphological features with accuracies of 89.03% for area

  1. A Framework for Fully Automated Performance Testing for Smart Buildings

    DEFF Research Database (Denmark)

    Markoska, Elena; Johansen, Aslak; Lazarova-Molnar, Sanja

    2018-01-01

    , setup of performance tests has been manual and labor-intensive and has required intimate knowledge of buildings’ complexity and systems. The emergence of the concept of smart buildings has provided an opportunity to overcome this restriction. In this paper, we propose a framework for automated......A significant proportion of energy consumption by buildings worldwide, estimated to ca. 40%, has yielded a high importance to studying buildings’ performance. Performance testing is a mean by which buildings can be continuously commissioned to ensure that they operate as designed. Historically...... performance testing of smart buildings that utilizes metadata models. The approach features automatic detection of applicable performance tests using metadata queries and their corresponding instantiation, as well as continuous commissioning based on metadata. The presented approach has been implemented...

  2. Test-retest reliability of automated whole body and compartmental muscle volume measurements on a wide bore 3T MR system

    Energy Technology Data Exchange (ETDEWEB)

    Thomas, Marianna S.; Newman, David; Kasmai, Bahman; Greenwood, Richard; Malcolm, Paul N. [Norfolk and Norwich University Hospital, Department of Radiology, Norwich (United Kingdom); Leinhard, Olof Dahlqvist [Linkoeping University, Center for Medical Image Science and Visualization, Linkoeping (Sweden); Linkoeping University, Department of Medical and Health Sciences, Linkoeping (Sweden); Karlsson, Anette; Borga, Magnus [Linkoeping University, Center for Medical Image Science and Visualization, Linkoeping (Sweden); Linkoeping University, Department of Biomedical Engineering, Linkoeping (Sweden); Rosander, Johannes [Advanced MR Analytics AB, Linkoeping (Sweden); Toms, Andoni P. [Norfolk and Norwich University Hospital, Department of Radiology, Norwich (United Kingdom); Radiology Academy, Cotman Centre, Norwich, Norfolk (United Kingdom)

    2014-09-15

    To measure the test-retest reproducibility of an automated system for quantifying whole body and compartmental muscle volumes using wide bore 3 T MRI. Thirty volunteers stratified by body mass index underwent whole body 3 T MRI, two-point Dixon sequences, on two separate occasions. Water-fat separation was performed, with automated segmentation of whole body, torso, upper and lower leg volumes, and manually segmented lower leg muscle volumes. Mean automated total body muscle volume was 19.32 L (SD9.1) and 19.28 L (SD9.12) for first and second acquisitions (Intraclass correlation coefficient (ICC) = 1.0, 95 % level of agreement -0.32-0.2 L). ICC for all automated test-retest muscle volumes were almost perfect (0.99-1.0) with 95 % levels of agreement 1.8-6.6 % of mean volume. Automated muscle volume measurements correlate closely with manual quantification (right lower leg: manual 1.68 L (2SD0.6) compared to automated 1.64 L (2SD 0.6), left lower leg: manual 1.69 L (2SD 0.64) compared to automated 1.63 L (SD0.61), correlation coefficients for automated and manual segmentation were 0.94-0.96). Fully automated whole body and compartmental muscle volume quantification can be achieved rapidly on a 3 T wide bore system with very low margins of error, excellent test-retest reliability and excellent correlation to manual segmentation in the lower leg. (orig.)

  3. Test-retest reliability of automated whole body and compartmental muscle volume measurements on a wide bore 3T MR system

    International Nuclear Information System (INIS)

    Thomas, Marianna S.; Newman, David; Kasmai, Bahman; Greenwood, Richard; Malcolm, Paul N.; Leinhard, Olof Dahlqvist; Karlsson, Anette; Borga, Magnus; Rosander, Johannes; Toms, Andoni P.

    2014-01-01

    To measure the test-retest reproducibility of an automated system for quantifying whole body and compartmental muscle volumes using wide bore 3 T MRI. Thirty volunteers stratified by body mass index underwent whole body 3 T MRI, two-point Dixon sequences, on two separate occasions. Water-fat separation was performed, with automated segmentation of whole body, torso, upper and lower leg volumes, and manually segmented lower leg muscle volumes. Mean automated total body muscle volume was 19.32 L (SD9.1) and 19.28 L (SD9.12) for first and second acquisitions (Intraclass correlation coefficient (ICC) = 1.0, 95 % level of agreement -0.32-0.2 L). ICC for all automated test-retest muscle volumes were almost perfect (0.99-1.0) with 95 % levels of agreement 1.8-6.6 % of mean volume. Automated muscle volume measurements correlate closely with manual quantification (right lower leg: manual 1.68 L (2SD0.6) compared to automated 1.64 L (2SD 0.6), left lower leg: manual 1.69 L (2SD 0.64) compared to automated 1.63 L (SD0.61), correlation coefficients for automated and manual segmentation were 0.94-0.96). Fully automated whole body and compartmental muscle volume quantification can be achieved rapidly on a 3 T wide bore system with very low margins of error, excellent test-retest reliability and excellent correlation to manual segmentation in the lower leg. (orig.)

  4. Measurement of the total antioxidant response in preeclampsia with a novel automated method.

    Science.gov (United States)

    Harma, Mehmet; Harma, Muge; Erel, Ozcan

    2005-01-10

    Preeclampsia is one of the most serious complications of pregnancy. Free radical damage has been implicated in the pathophysiology of this condition. In this study, we aimed to measure the antioxidant capacity in plasma samples from normotensive and preeclamptic pregnant women to evaluate their antioxidant status using a more recently developed automated measurement method. Our study group contained 42 women, 24 of whom had preeclampsia, while 18 had normotensive pregnancies. We measured the total plasma antioxidant capacity for all patients, as well as the levels of four major individual plasma antioxidant components; albumin, uric acid, ascorbic acid and bilirubin, and as a reciprocal measure, their total plasma peroxide levels. Statistically significant differences (determined using Student's t-test) were noted between the normotensive and the preeclamptic groups for their total antioxidant responses and their vitamin C levels (1.31 +/- 0.12 mmol versus 1.06 +/- 0.41 mmol Trolox eq./L; 30.2 +/- 17.83 micromol/L versus 18.1 +/- 11.37 micromol/L, respectively), which were both considerably reduced in the preeclamptic patients. In contrast, the total plasma peroxide levels were significantly elevated in this group (49.8 +/- 14.3 micromol/L versus 38.8 +/- 9.6 micromol/L). We found a decreased total antioxidant response in preeclamptic patients using a simple, rapid and reliable automated colorimetric assay, which may suitable for use in any routine clinical biochemistry laboratory, and considerably facilitates the assessment of this useful clinical parameter. We suggest that this novel method may be used as a routine test to evaluate and follow up of the levels of oxidative stress in preeclampsia.

  5. [A comparative study between the Vitek YBC and Microscan Walk Away RYID automated systems with conventional phenotypic methods for the identification of yeasts of clinical interest].

    Science.gov (United States)

    Ferrara, Giuseppe; Mercedes Panizol, Maria; Mazzone, Marja; Delia Pequeneze, Maria; Reviakina, Vera

    2014-12-01

    The aim of this study was to compare the identification of clin- ically relevant yeasts by the Vitek YBC and Microscan Walk Away RYID automated methods with conventional phenotypic methods. One hundred and ninety three yeast strains isolated from clinical samples and five controls strains were used. All the yeasts were identified by the automated methods previously mentioned and conventional phenotypic methods such as carbohydrate assimilation, visualization of microscopic morphology on corn meal agar and the use of chromogenic agar. Variables were assessed by 2 x 2 contingency tables, McNemar's Chi square, the Kappa index, and concordance values were calculated, as well as major and minor errors for the automated methods. Yeasts were divided into two groups: (1) frequent isolation and (2) rare isolation. The Vitek YBC and Microscan Walk Away RYID systems were concordant in 88.4 and 85.9% respectively, when compared to conventional phenotypic methods. Although both automated systems can be used for yeasts identification, the presence of major and minor errors indicates the possibility of misidentifications; therefore, the operator of this equipment must use in parallel, phenotypic tests such as visualization of microscopic morphology on corn meal agar and chromogenic agar, especially against infrequently isolated yeasts. Automated systems are a valuable tool; however, the expertise and judgment of the microbiologist are an important strength to ensure the quality of the results.

  6. Automation of eddy current system for in-service inspection of turbine and generator bores

    International Nuclear Information System (INIS)

    Viertl, J.R.M.

    1988-01-01

    The most commonly applied inspection method for ferromagnetic turbine and generator rotor bores is the magnetic particle test technique. This method is subjective, depends on the test operator's skill and diligence in identifying test indications, and suffers from poor repeatability, especially for small indications. Automation would improve repeatability. However, magnetic particle tests are not easily automated, because the data are in the form of sketches, photographs, and written and oral descriptions of the indications. Eddy current inspection has obvious potential to replace magnetic particle methods in this application. Eddy current tests can be readily automated, as the data are in the form of voltages that can be recorded, digitized, and manipulated by a computer. The current project continues the investigation of the correlation between eddy current and magnetic particle inspection. Two systems have been combined to acquire eddy current data automatically. This combination of systems consists of the Nortec-25L Eddyscope (to provide the analog eddy current signals) and the General Electric DATAQ (TM) System (to perform the automatic data acquisition). The automation of the system is discussed

  7. Method for semi-automated microscopy of filtration-enriched circulating tumor cells

    International Nuclear Information System (INIS)

    Pailler, Emma; Oulhen, Marianne; Billiot, Fanny; Galland, Alexandre; Auger, Nathalie; Faugeroux, Vincent; Laplace-Builhé, Corinne; Besse, Benjamin; Loriot, Yohann; Ngo-Camus, Maud; Hemanda, Merouan; Lindsay, Colin R.; Soria, Jean-Charles; Vielh, Philippe; Farace, Françoise

    2016-01-01

    Circulating tumor cell (CTC)-filtration methods capture high numbers of CTCs in non-small-cell lung cancer (NSCLC) and metastatic prostate cancer (mPCa) patients, and hold promise as a non-invasive technique for treatment selection and disease monitoring. However filters have drawbacks that make the automation of microscopy challenging. We report the semi-automated microscopy method we developed to analyze filtration-enriched CTCs from NSCLC and mPCa patients. Spiked cell lines in normal blood and CTCs were enriched by ISET (isolation by size of epithelial tumor cells). Fluorescent staining was carried out using epithelial (pan-cytokeratins, EpCAM), mesenchymal (vimentin, N-cadherin), leukocyte (CD45) markers and DAPI. Cytomorphological staining was carried out with Mayer-Hemalun or Diff-Quik. ALK-, ROS1-, ERG-rearrangement were detected by filter-adapted-FISH (FA-FISH). Microscopy was carried out using an Ariol scanner. Two combined assays were developed. The first assay sequentially combined four-color fluorescent staining, scanning, automated selection of CD45 − cells, cytomorphological staining, then scanning and analysis of CD45 − cell phenotypical and cytomorphological characteristics. CD45 − cell selection was based on DAPI and CD45 intensity, and a nuclear area >55 μm 2 . The second assay sequentially combined fluorescent staining, automated selection of CD45 − cells, FISH scanning on CD45 − cells, then analysis of CD45 − cell FISH signals. Specific scanning parameters were developed to deal with the uneven surface of filters and CTC characteristics. Thirty z-stacks spaced 0.6 μm apart were defined as the optimal setting, scanning 82 %, 91 %, and 95 % of CTCs in ALK-, ROS1-, and ERG-rearranged patients respectively. A multi-exposure protocol consisting of three separate exposure times for green and red fluorochromes was optimized to analyze the intensity, size and thickness of FISH signals. The semi-automated microscopy method reported here

  8. A mobile, high-throughput semi-automated system for testing cognition in large non-primate animal models of Huntington disease.

    Science.gov (United States)

    McBride, Sebastian D; Perentos, Nicholas; Morton, A Jennifer

    2016-05-30

    For reasons of cost and ethical concerns, models of neurodegenerative disorders such as Huntington disease (HD) are currently being developed in farm animals, as an alternative to non-human primates. Developing reliable methods of testing cognitive function is essential to determining the usefulness of such models. Nevertheless, cognitive testing of farm animal species presents a unique set of challenges. The primary aims of this study were to develop and validate a mobile operant system suitable for high throughput cognitive testing of sheep. We designed a semi-automated testing system with the capability of presenting stimuli (visual, auditory) and reward at six spatial locations. Fourteen normal sheep were used to validate the system using a two-choice visual discrimination task. Four stages of training devised to acclimatise animals to the system are also presented. All sheep progressed rapidly through the training stages, over eight sessions. All sheep learned the 2CVDT and performed at least one reversal stage. The mean number of trials the sheep took to reach criterion in the first acquisition learning was 13.9±1.5 and for the reversal learning was 19.1±1.8. This is the first mobile semi-automated operant system developed for testing cognitive function in sheep. We have designed and validated an automated operant behavioural testing system suitable for high throughput cognitive testing in sheep and other medium-sized quadrupeds, such as pigs and dogs. Sheep performance in the two-choice visual discrimination task was very similar to that reported for non-human primates and strongly supports the use of farm animals as pre-clinical models for the study of neurodegenerative diseases. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Selection of Filtration Methods in the Analysis of Motion of Automated Guided Vehicle

    Directory of Open Access Journals (Sweden)

    Dobrzańska Magdalena

    2016-08-01

    Full Text Available In this article the issues related to mapping the route and error correction in automated guided vehicle (AGV movement have been discussed. The nature and size of disruption have been determined using the registered runs in experimental studies. On the basis of the analysis a number of numerical runs have been generated, which mapped possible to obtain runs in a real movement of the vehicle. The obtained data set has been used for further research. The aim of this paper was to test the selected methods of digital filtering on the same data set and determine their effectiveness. The results of simulation studies have been presented in the article. The effectiveness of various methods has been determined and on this basis the conclusions have been drawn.

  10. E-learning platform for automated testing of electronic circuits using signature analysis method

    Science.gov (United States)

    Gherghina, Cǎtǎlina; Bacivarov, Angelica; Bacivarov, Ioan C.; Petricǎ, Gabriel

    2016-12-01

    Dependability of electronic circuits can be ensured only through testing of circuit modules. This is done by generating test vectors and their application to the circuit. Testability should be viewed as a concerted effort to ensure maximum efficiency throughout the product life cycle, from conception and design stage, through production to repairs during products operating. In this paper, is presented the platform developed by authors for training for testability in electronics, in general and in using signature analysis method, in particular. The platform allows highlighting the two approaches in the field namely analog and digital signature of circuits. As a part of this e-learning platform, it has been developed a database for signatures of different electronic components meant to put into the spotlight different techniques implying fault detection, and from this there were also self-repairing techniques of the systems with this kind of components. An approach for realizing self-testing circuits based on MATLAB environment and using signature analysis method is proposed. This paper analyses the benefits of signature analysis method and simulates signature analyzer performance based on the use of pseudo-random sequences, too.

  11. Orbit transfer rocket engine technology program: Automated preflight methods concept definition

    Science.gov (United States)

    Erickson, C. M.; Hertzberg, D. W.

    1991-01-01

    The possibility of automating preflight engine checkouts on orbit transfer engines is discussed. The minimum requirements in terms of information and processing necessary to assess the engine'e integrity and readiness to perform its mission were first defined. A variety of ways for remotely obtaining that information were generated. The sophistication of these approaches varied from a simple preliminary power up, where the engine is fired up for the first time, to the most advanced approach where the sensor and operational history data system alone indicates engine integrity. The critical issues and benefits of these methods were identified, outlined, and prioritized. The technology readiness of each of these automated preflight methods were then rated on a NASA Office of Exploration scale used for comparing technology options for future mission choices. Finally, estimates were made of the remaining cost to advance the technology for each method to a level where the system validation models have been demonstrated in a simulated environment.

  12. Large-scale automated analysis of news media: a novel computational method for obesity policy research.

    Science.gov (United States)

    Hamad, Rita; Pomeranz, Jennifer L; Siddiqi, Arjumand; Basu, Sanjay

    2015-02-01

    Analyzing news media allows obesity policy researchers to understand popular conceptions about obesity, which is important for targeting health education and policies. A persistent dilemma is that investigators have to read and manually classify thousands of individual news articles to identify how obesity and obesity-related policy proposals may be described to the public in the media. A machine learning method called "automated content analysis" that permits researchers to train computers to "read" and classify massive volumes of documents was demonstrated. 14,302 newspaper articles that mentioned the word "obesity" during 2011-2012 were identified. Four states that vary in obesity prevalence and policy (Alabama, California, New Jersey, and North Carolina) were examined. The reliability of an automated program to categorize the media's framing of obesity as an individual-level problem (e.g., diet) and/or an environmental-level problem (e.g., obesogenic environment) was tested. The automated program performed similarly to human coders. The proportion of articles with individual-level framing (27.7-31.0%) was higher than the proportion with neutral (18.0-22.1%) or environmental-level framing (16.0-16.4%) across all states and over the entire study period (Pnews media was demonstrated. © 2014 The Obesity Society.

  13. Low cost automation

    International Nuclear Information System (INIS)

    1987-03-01

    This book indicates method of building of automation plan, design of automation facilities, automation and CHIP process like basics of cutting, NC processing machine and CHIP handling, automation unit, such as drilling unit, tapping unit, boring unit, milling unit and slide unit, application of oil pressure on characteristics and basic oil pressure circuit, application of pneumatic, automation kinds and application of process, assembly, transportation, automatic machine and factory automation.

  14. Validation of shortened 2-day sterility testing of mesenchymal stem cell-based therapeutic preparation on an automated culture system.

    Science.gov (United States)

    Lysák, Daniel; Holubová, Monika; Bergerová, Tamara; Vávrová, Monika; Cangemi, Giuseppina Cristina; Ciccocioppo, Rachele; Kruzliak, Peter; Jindra, Pavel

    2016-03-01

    Cell therapy products represent a new trend of treatment in the field of immunotherapy and regenerative medicine. Their biological nature and multistep preparation procedure require the application of complex release criteria and quality control. Microbial contamination of cell therapy products is a potential source of morbidity in recipients. The automated blood culture systems are widely used for the detection of microorganisms in cell therapy products. However the standard 2-week cultivation period is too long for some cell-based treatments and alternative methods have to be devised. We tried to verify whether a shortened cultivation of the supernatant from the mesenchymal stem cell (MSC) culture obtained 2 days before the cell harvest could sufficiently detect microbial growth and allow the release of MSC for clinical application. We compared the standard Ph. Eur. cultivation method and the automated blood culture system BACTEC (Becton Dickinson). The time to detection (TTD) and the detection limit were analyzed for three bacterial and two fungal strains. The Staphylococcus aureus and Pseudomonas aeruginosa were recognized within 24 h with both methods (detection limit ~10 CFU). The time required for the detection of Bacillus subtilis was shorter with the automated method (TTD 10.3 vs. 60 h for 10-100 CFU). The BACTEC system reached significantly shorter times to the detection of Candida albicans and Aspergillus brasiliensis growth compared to the classical method (15.5 vs. 48 and 31.5 vs. 48 h, respectively; 10-100 CFU). The positivity was demonstrated within 48 h in all bottles, regardless of the size of the inoculum. This study validated the automated cultivation system as a method able to detect all tested microorganisms within a 48-h period with a detection limit of ~10 CFU. Only in case of B. subtilis, the lowest inoculum (~10 CFU) was not recognized. The 2-day cultivation technique is then capable of confirming the microbiological safety of MSC and

  15. A computer vision-based automated Figure-8 maze for working memory test in rodents.

    Science.gov (United States)

    Pedigo, Samuel F; Song, Eun Young; Jung, Min Whan; Kim, Jeansok J

    2006-09-30

    The benchmark test for prefrontal cortex (PFC)-mediated working memory in rodents is a delayed alternation task utilizing variations of T-maze or Figure-8 maze, which requires the animals to make specific arm entry responses for reward. In this task, however, manual procedures involved in shaping target behavior, imposing delays between trials and delivering rewards can potentially influence the animal's performance on the maze. Here, we report an automated Figure-8 maze which does not necessitate experimenter-subject interaction during shaping, training or testing. This system incorporates a computer vision system for tracking, motorized gates to impose delays, and automated reward delivery. The maze is controlled by custom software that records the animal's location and activates the gates according to the animal's behavior and a control algorithm. The program performs calculations of task accuracy, tracks movement sequence through the maze, and provides other dependent variables (such as running speed, time spent in different maze locations, activity level during delay). Testing in rats indicates that the performance accuracy is inversely proportional to the delay interval, decreases with PFC lesions, and that animals anticipate timing during long delays. Thus, our automated Figure-8 maze is effective at assessing working memory and provides novel behavioral measures in rodents.

  16. Test-retest reliability of automated whole body and compartmental muscle volume measurements on a wide bore 3T MR system.

    Science.gov (United States)

    Thomas, Marianna S; Newman, David; Leinhard, Olof Dahlqvist; Kasmai, Bahman; Greenwood, Richard; Malcolm, Paul N; Karlsson, Anette; Rosander, Johannes; Borga, Magnus; Toms, Andoni P

    2014-09-01

    To measure the test-retest reproducibility of an automated system for quantifying whole body and compartmental muscle volumes using wide bore 3 T MRI. Thirty volunteers stratified by body mass index underwent whole body 3 T MRI, two-point Dixon sequences, on two separate occasions. Water-fat separation was performed, with automated segmentation of whole body, torso, upper and lower leg volumes, and manually segmented lower leg muscle volumes. Mean automated total body muscle volume was 19·32 L (SD9·1) and 19·28 L (SD9·12) for first and second acquisitions (Intraclass correlation coefficient (ICC) = 1·0, 95% level of agreement -0·32-0·2 L). ICC for all automated test-retest muscle volumes were almost perfect (0·99-1·0) with 95% levels of agreement 1.8-6.6% of mean volume. Automated muscle volume measurements correlate closely with manual quantification (right lower leg: manual 1·68 L (2SD0·6) compared to automated 1·64 L (2SD 0·6), left lower leg: manual 1·69 L (2SD 0·64) compared to automated 1·63 L (SD0·61), correlation coefficients for automated and manual segmentation were 0·94-0·96). Fully automated whole body and compartmental muscle volume quantification can be achieved rapidly on a 3 T wide bore system with very low margins of error, excellent test-retest reliability and excellent correlation to manual segmentation in the lower leg. Sarcopaenia is an important reversible complication of a number of diseases. Manual quantification of muscle volume is time-consuming and expensive. Muscles can be imaged using in and out of phase MRI. Automated atlas-based segmentation can identify muscle groups. Automated muscle volume segmentation is reproducible and can replace manual measurements.

  17. Automated property optimization via ab initio O(N) elongation method: Application to (hyper-)polarizability in DNA

    Energy Technology Data Exchange (ETDEWEB)

    Orimoto, Yuuichi, E-mail: orimoto.yuuichi.888@m.kyushu-u.ac.jp [Department of Material Sciences, Faculty of Engineering Sciences, Kyushu University, 6-1 Kasuga-Park, Fukuoka 816-8580 (Japan); Aoki, Yuriko [Department of Material Sciences, Faculty of Engineering Sciences, Kyushu University, 6-1 Kasuga-Park, Fukuoka 816-8580 (Japan); Japan Science and Technology Agency, CREST, 4-1-8 Hon-chou, Kawaguchi, Saitama 332-0012 (Japan)

    2016-07-14

    An automated property optimization method was developed based on the ab initio O(N) elongation (ELG) method and applied to the optimization of nonlinear optical (NLO) properties in DNA as a first test. The ELG method mimics a polymerization reaction on a computer, and the reaction terminal of a starting cluster is attacked by monomers sequentially to elongate the electronic structure of the system by solving in each step a limited space including the terminal (localized molecular orbitals at the terminal) and monomer. The ELG-finite field (ELG-FF) method for calculating (hyper-)polarizabilities was used as the engine program of the optimization method, and it was found to show linear scaling efficiency while maintaining high computational accuracy for a random sequenced DNA model. Furthermore, the self-consistent field convergence was significantly improved by using the ELG-FF method compared with a conventional method, and it can lead to more feasible NLO property values in the FF treatment. The automated optimization method successfully chose an appropriate base pair from four base pairs (A, T, G, and C) for each elongation step according to an evaluation function. From test optimizations for the first order hyper-polarizability (β) in DNA, a substantial difference was observed depending on optimization conditions between “choose-maximum” (choose a base pair giving the maximum β for each step) and “choose-minimum” (choose a base pair giving the minimum β). In contrast, there was an ambiguous difference between these conditions for optimizing the second order hyper-polarizability (γ) because of the small absolute value of γ and the limitation of numerical differential calculations in the FF method. It can be concluded that the ab initio level property optimization method introduced here can be an effective step towards an advanced computer aided material design method as long as the numerical limitation of the FF method is taken into account.

  18. Automated property optimization via ab initio O(N) elongation method: Application to (hyper-)polarizability in DNA

    International Nuclear Information System (INIS)

    Orimoto, Yuuichi; Aoki, Yuriko

    2016-01-01

    An automated property optimization method was developed based on the ab initio O(N) elongation (ELG) method and applied to the optimization of nonlinear optical (NLO) properties in DNA as a first test. The ELG method mimics a polymerization reaction on a computer, and the reaction terminal of a starting cluster is attacked by monomers sequentially to elongate the electronic structure of the system by solving in each step a limited space including the terminal (localized molecular orbitals at the terminal) and monomer. The ELG-finite field (ELG-FF) method for calculating (hyper-)polarizabilities was used as the engine program of the optimization method, and it was found to show linear scaling efficiency while maintaining high computational accuracy for a random sequenced DNA model. Furthermore, the self-consistent field convergence was significantly improved by using the ELG-FF method compared with a conventional method, and it can lead to more feasible NLO property values in the FF treatment. The automated optimization method successfully chose an appropriate base pair from four base pairs (A, T, G, and C) for each elongation step according to an evaluation function. From test optimizations for the first order hyper-polarizability (β) in DNA, a substantial difference was observed depending on optimization conditions between “choose-maximum” (choose a base pair giving the maximum β for each step) and “choose-minimum” (choose a base pair giving the minimum β). In contrast, there was an ambiguous difference between these conditions for optimizing the second order hyper-polarizability (γ) because of the small absolute value of γ and the limitation of numerical differential calculations in the FF method. It can be concluded that the ab initio level property optimization method introduced here can be an effective step towards an advanced computer aided material design method as long as the numerical limitation of the FF method is taken into account.

  19. Remote systems and automation in radioactive waste package handling

    International Nuclear Information System (INIS)

    Gneiting, B.C.; Hayward, M.L.

    1987-01-01

    A proof-of-principle test was conducted at the Hanford Engineering Development Laboratory (HEDL) to demonstrate the feasibility of performing cask receiving and unloading operations in a remote and partially automated manner. This development testing showed feasibility of performing critical cask receipt, preparation, and unloading operations from a single control station using remote controls and indirect viewing. Using robotics and remote automation in a cask handling system can result in lower personnel exposure levels and cask turnaround times while maintaining operational flexibility. An automated cask handling system presents a flexible state-of-the-art, cost effective alternative solution to hands-on methods that have been used in the past

  20. Automation of Classical QEEG Trending Methods for Early Detection of Delayed Cerebral Ischemia: More Work to Do.

    Science.gov (United States)

    Wickering, Ellis; Gaspard, Nicolas; Zafar, Sahar; Moura, Valdery J; Biswal, Siddharth; Bechek, Sophia; OʼConnor, Kathryn; Rosenthal, Eric S; Westover, M Brandon

    2016-06-01

    The purpose of this study is to evaluate automated implementations of continuous EEG monitoring-based detection of delayed cerebral ischemia based on methods used in classical retrospective studies. We studied 95 patients with either Fisher 3 or Hunt Hess 4 to 5 aneurysmal subarachnoid hemorrhage who were admitted to the Neurosciences ICU and underwent continuous EEG monitoring. We implemented several variations of two classical algorithms for automated detection of delayed cerebral ischemia based on decreases in alpha-delta ratio and relative alpha variability. Of 95 patients, 43 (45%) developed delayed cerebral ischemia. Our automated implementation of the classical alpha-delta ratio-based trending method resulted in a sensitivity and specificity (Se,Sp) of (80,27)%, compared with the values of (100,76)% reported in the classic study using similar methods in a nonautomated fashion. Our automated implementation of the classical relative alpha variability-based trending method yielded (Se,Sp) values of (65,43)%, compared with (100,46)% reported in the classic study using nonautomated analysis. Our findings suggest that improved methods to detect decreases in alpha-delta ratio and relative alpha variability are needed before an automated EEG-based early delayed cerebral ischemia detection system is ready for clinical use.

  1. Automation of testing the metrological reliability of nondestructive control systems

    International Nuclear Information System (INIS)

    Zhukov, Yu.A.; Isakov, V.B.; Karlov, Yu.K.; Kovalevskij, Yu.A.

    1987-01-01

    Opportunities of microcomputers are used to solve the problem of testing control-measuring systems. Besides the main program the program of data processing when characterizing the nondestructive control systems is written in the microcomputer. The program includes two modules. The first module contains tests-programs, by which accuracy of functional elements of the microcomputer and interface elements with issuing a message to the operator on readiness of the elements for operation and failure of a certain element are determined. The second module includes: calculational programs when determining metrological reliability of measuring channel reliability, a calculational subprogram for random statistical measuring error, time instability and ''dead time''. Automation of testing metrological reliability of the nondestructive control systems increases reliability of determining metrological parameters and reduces time of system testing

  2. A New Automated Method and Sample Data Flow for Analysis of Volatile Nitrosamines in Human Urine*

    Science.gov (United States)

    Hodgson, James A.; Seyler, Tiffany H.; McGahee, Ernest; Arnstein, Stephen; Wang, Lanqing

    2016-01-01

    Volatile nitrosamines (VNAs) are a group of compounds classified as probable (group 2A) and possible (group 2B) carcinogens in humans. Along with certain foods and contaminated drinking water, VNAs are detected at high levels in tobacco products and in both mainstream and sidestream smoke. Our laboratory monitors six urinary VNAs—N-nitrosodimethylamine (NDMA), N-nitrosomethylethylamine (NMEA), N-nitrosodiethylamine (NDEA), N-nitrosopiperidine (NPIP), N-nitrosopyrrolidine (NPYR), and N-nitrosomorpholine (NMOR)—using isotope dilution GC-MS/MS (QQQ) for large population studies such as the National Health and Nutrition Examination Survey (NHANES). In this paper, we report for the first time a new automated sample preparation method to more efficiently quantitate these VNAs. Automation is done using Hamilton STAR™ and Caliper Staccato™ workstations. This new automated method reduces sample preparation time from 4 hours to 2.5 hours while maintaining precision (inter-run CV < 10%) and accuracy (85% - 111%). More importantly this method increases sample throughput while maintaining a low limit of detection (<10 pg/mL) for all analytes. A streamlined sample data flow was created in parallel to the automated method, in which samples can be tracked from receiving to final LIMs output with minimal human intervention, further minimizing human error in the sample preparation process. This new automated method and the sample data flow are currently applied in bio-monitoring of VNAs in the US non-institutionalized population NHANES 2013-2014 cycle. PMID:26949569

  3. Development of performance tests for an automated MC and A system

    International Nuclear Information System (INIS)

    Kok, K.D.; Klingensmith, R.W.; Riffle, W.; Carver, R.D.; Schumacher, S.S.; Lavender, J.C.; Smith, B.W.

    1988-01-01

    Performance tests of MC and A systems using computers are described, and some example scenarios are discussed. Facility personnel or an external inspection group may use performance tests to evaluate MC and A capabilities under actual operating conditions. This paper addresses test elements common to both user groups. Performance tests consist of scenario development, security, and safety measures, conduct, and evaluation. Because exercises often test scenarios against which the MC and A system is protecting, they may require additional security and safety measures. Computer systems enhance MC and A by providing greater speed, increased precision, and automated checks. Performance tests for MC and A systems using computers differ from performance tests employing manual data systems in that the scenarios must anticipate computer actions rather than utilize controllers to adjust the scenario

  4. Comparative performance evaluation of automated segmentation methods of hippocampus from magnetic resonance images of temporal lobe epilepsy patients.

    Science.gov (United States)

    Hosseini, Mohammad-Parsa; Nazem-Zadeh, Mohammad-Reza; Pompili, Dario; Jafari-Khouzani, Kourosh; Elisevich, Kost; Soltanian-Zadeh, Hamid

    2016-01-01

    Segmentation of the hippocampus from magnetic resonance (MR) images is a key task in the evaluation of mesial temporal lobe epilepsy (mTLE) patients. Several automated algorithms have been proposed although manual segmentation remains the benchmark. Choosing a reliable algorithm is problematic since structural definition pertaining to multiple edges, missing and fuzzy boundaries, and shape changes varies among mTLE subjects. Lack of statistical references and guidance for quantifying the reliability and reproducibility of automated techniques has further detracted from automated approaches. The purpose of this study was to develop a systematic and statistical approach using a large dataset for the evaluation of automated methods and establish a method that would achieve results better approximating those attained by manual tracing in the epileptogenic hippocampus. A template database of 195 (81 males, 114 females; age range 32-67 yr, mean 49.16 yr) MR images of mTLE patients was used in this study. Hippocampal segmentation was accomplished manually and by two well-known tools (FreeSurfer and hammer) and two previously published methods developed at their institution [Automatic brain structure segmentation (ABSS) and LocalInfo]. To establish which method was better performing for mTLE cases, several voxel-based, distance-based, and volume-based performance metrics were considered. Statistical validations of the results using automated techniques were compared with the results of benchmark manual segmentation. Extracted metrics were analyzed to find the method that provided a more similar result relative to the benchmark. Among the four automated methods, ABSS generated the most accurate results. For this method, the Dice coefficient was 5.13%, 14.10%, and 16.67% higher, Hausdorff was 22.65%, 86.73%, and 69.58% lower, precision was 4.94%, -4.94%, and 12.35% higher, and the root mean square (RMS) was 19.05%, 61.90%, and 65.08% lower than LocalInfo, FreeSurfer, and

  5. GESCAL: Quality management automated system for a calibration and test laboratory

    International Nuclear Information System (INIS)

    Manzano de Armas, J.; Valdes Ramos, M.; Morales Monzon, J.A.

    1998-01-01

    GESCAL is a software created to automate all elements composing the quality system in a calibration and test laboratory. It also evaluates quality according to its objectives and policies. This integrated data system decreases considerably the amount of time devoted to manage quality. It is speedier in searching and evaluating information registers thus notably in reducing the workload for laboratory staff

  6. Mechanical properties of bovine cortical bone based on the automated ball indentation technique and graphics processing method.

    Science.gov (United States)

    Zhang, Airong; Zhang, Song; Bian, Cuirong

    2018-02-01

    Cortical bone provides the main form of support in humans and other vertebrates against various forces. Thus, capturing its mechanical properties is important. In this study, the mechanical properties of cortical bone were investigated by using automated ball indentation and graphics processing at both the macroscopic and microstructural levels under dry conditions. First, all polished samples were photographed under a metallographic microscope, and the area ratio of the circumferential lamellae and osteons was calculated through the graphics processing method. Second, fully-computer-controlled automated ball indentation (ABI) tests were performed to explore the micro-mechanical properties of the cortical bone at room temperature and a constant indenter speed. The indentation defects were examined with a scanning electron microscope. Finally, the macroscopic mechanical properties of the cortical bone were estimated with the graphics processing method and mixture rule. Combining ABI and graphics processing proved to be an effective tool to obtaining the mechanical properties of the cortical bone, and the indenter size had a significant effect on the measurement. The methods presented in this paper provide an innovative approach to acquiring the macroscopic mechanical properties of cortical bone in a nondestructive manner. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Automated immunohistochemical method to analyze large areas of the human cortex.

    Science.gov (United States)

    Abbass, Mohamad; Trought, Kathleen; Long, David; Semechko, Anton; Wong, Albert H C

    2018-01-15

    There have been inconsistencies in the histological abnormalities found in the cerebral cortex from patients with schizophrenia, bipolar disorder and major depression. Discrepancies in previously published reports may arise from small sample sizes, inconsistent methodology and biased cell counting. We applied automated quantification of neuron density, neuron size and cortical layer thickness in large regions of the cerebral cortex in psychiatric patients. This method accurately segments DAPI positive cells that are also stained with CUX2 and FEZF2. Cortical layer thickness, neuron density and neuron size were automatically computed for each cortical layer in numerous Brodmann areas. We did not find pronounced cytoarchitectural abnormalities in the anterior cingulate cortex or orbitofrontal cortex in patients with schizophrenia, bipolar disorder or major depressive disorder. There were no significant differences in layer thickness measured in immunohistochemically stained slides compared with traditional Nissl stained slides. Automated cell counts were correlated, reliable and consistent with manual counts, while being much less time-consuming. We demonstrate the validity of using a novel automated analysis approach to post-mortem brain tissue. We were able to analyze large cortical areas and quantify specific cell populations using immunohistochemical markers. Future analyses could benefit from efficient automated analysis. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. A pattern-based method to automate mask inspection files

    Science.gov (United States)

    Kamal Baharin, Ezni Aznida Binti; Muhsain, Mohamad Fahmi Bin; Ahmad Ibrahim, Muhamad Asraf Bin; Ahmad Noorhani, Ahmad Nurul Ihsan Bin; Sweis, Jason; Lai, Ya-Chieh; Hurat, Philippe

    2017-03-01

    Mask inspection is a critical step in the mask manufacturing process in order to ensure all dimensions printed are within the needed tolerances. This becomes even more challenging as the device nodes shrink and the complexity of the tapeout increases. Thus, the amount of measurement points and their critical dimension (CD) types are increasing to ensure the quality of the mask. In addition to the mask quality, there is a significant amount of manpower needed when the preparation and debugging of this process are not automated. By utilizing a novel pattern search technology with the ability to measure and report match region scan-line (edge) measurements, we can create a flow to find, measure and mark all metrology locations of interest and provide this automated report to the mask shop for inspection. A digital library is created based on the technology product and node which contains the test patterns to be measured. This paper will discuss how these digital libraries will be generated and then utilized. As a time-critical part of the manufacturing process, this can also reduce the data preparation cycle time, minimize the amount of manual/human error in naming and measuring the various locations, reduce the risk of wrong/missing CD locations, and reduce the amount of manpower needed overall. We will also review an example pattern and how the reporting structure to the mask shop can be processed. This entire process can now be fully automated.

  9. Investigation of the performance of digital mammographic X-Ray equipment: Determination of noise equivalent quanta (NEQQC) and detective quantum efficiency (DQEQC) compared with the automated analysis of CDMAM test images with CDCOM and CDIC programs

    International Nuclear Information System (INIS)

    Loos, C.; Buhr, H.; Blendl, C.

    2013-01-01

    Purpose: The purpose of this study was to determine the values for noise equivalent quanta, detective quantum efficiency, modulation transfer function, noise power spectrum, and the values for the parameters for automated CDMAM test phantom analyses required to achieve satisfactory quality of digital mammograms. Materials and Methods: During the course of tests according to PAS 1054 (8 CR and 12 DR systems), test images were made with a test phantom insertion plate containing two lead edges in nearly horizontal and vertical directions. Only original data were processed with a program that was developed at the Cologne University of Applied Sciences (FH-Koeln). All equipment systems complied with the requirements regarding visual recognition of gold-plated mammo detail test objects. CDMAM test images were also evaluated using the CDIC (CUAS) and CDCOM (EUREF) programs. Results: CDMAM test images show comparable values for the parameters, precision, sensitivity and specificity. DR systems require about half the dose used for CR systems for similar results. The NEQ values achieved with the dose used for the CDMAM test images show larger scatter ranges. The MTF of the different equipment system types differ significantly from each other. Conclusion: Visual evaluation of CDMAM test images can be replaced by automated evaluation. Limiting values were determined for each parameter. Automated evaluation of CDMAM test phantom images should be used to determine the physical parameter NEQ QC . This method is much more sensitive to noise and sharpness influences and has a higher validity than diagnostic methods. Automated evaluation objectivizes testing. (orig.)

  10. Automated Cervical Screening and Triage, Based on HPV Testing and Computer-Interpreted Cytology.

    Science.gov (United States)

    Yu, Kai; Hyun, Noorie; Fetterman, Barbara; Lorey, Thomas; Raine-Bennett, Tina R; Zhang, Han; Stamps, Robin E; Poitras, Nancy E; Wheeler, William; Befano, Brian; Gage, Julia C; Castle, Philip E; Wentzensen, Nicolas; Schiffman, Mark

    2018-04-11

    State-of-the-art cervical cancer prevention includes human papillomavirus (HPV) vaccination among adolescents and screening/treatment of cervical precancer (CIN3/AIS and, less strictly, CIN2) among adults. HPV testing provides sensitive detection of precancer but, to reduce overtreatment, secondary "triage" is needed to predict women at highest risk. Those with the highest-risk HPV types or abnormal cytology are commonly referred to colposcopy; however, expert cytology services are critically lacking in many regions. To permit completely automatable cervical screening/triage, we designed and validated a novel triage method, a cytologic risk score algorithm based on computer-scanned liquid-based slide features (FocalPoint, BD, Burlington, NC). We compared it with abnormal cytology in predicting precancer among 1839 women testing HPV positive (HC2, Qiagen, Germantown, MD) in 2010 at Kaiser Permanente Northern California (KPNC). Precancer outcomes were ascertained by record linkage. As additional validation, we compared the algorithm prospectively with cytology results among 243 807 women screened at KPNC (2016-2017). All statistical tests were two-sided. Among HPV-positive women, the algorithm matched the triage performance of abnormal cytology. Combined with HPV16/18/45 typing (Onclarity, BD, Sparks, MD), the automatable strategy referred 91.7% of HPV-positive CIN3/AIS cases to immediate colposcopy while deferring 38.4% of all HPV-positive women to one-year retesting (compared with 89.1% and 37.4%, respectively, for typing and cytology triage). In the 2016-2017 validation, the predicted risk scores strongly correlated with cytology (P < .001). High-quality cervical screening and triage performance is achievable using this completely automated approach. Automated technology could permit extension of high-quality cervical screening/triage coverage to currently underserved regions.

  11. Automated ultrasonic pipe weld inspection. Part 1

    International Nuclear Information System (INIS)

    Karl Deutsch, W.A.; Schulte, P.; Joswig, M.; Kattwinkel, R.

    2006-01-01

    This article contains a brief overview on automated ultrasonic welded inspection for various pipe types. Some inspection steps might by carried out with portable test equipment (e.g. pipe and test), but the weld inspection in all internationally relevant specification must be automated. The pipe geometry, the production process, and the pipe usage determine the number of required probes. Recent updates for some test specifications enforce a large number of ultrasonic probes, e.g. the Shell standard. Since seamless pipes are sometimes replaced by ERW pipes and LSAW pipes (in both cases to save production cost), the inspection methods change gradually between the various pipe types. Each testing system is unique and shows its specialties which have to be discussed by supplier, testing system user and final customer of the pipe. (author)

  12. A Comparison of Two Scoring Methods for an Automated Speech Scoring System

    Science.gov (United States)

    Xi, Xiaoming; Higgins, Derrick; Zechner, Klaus; Williamson, David

    2012-01-01

    This paper compares two alternative scoring methods--multiple regression and classification trees--for an automated speech scoring system used in a practice environment. The two methods were evaluated on two criteria: construct representation and empirical performance in predicting human scores. The empirical performance of the two scoring models…

  13. Laboratory automation: trajectory, technology, and tactics.

    Science.gov (United States)

    Markin, R S; Whalen, S A

    2000-05-01

    Laboratory automation is in its infancy, following a path parallel to the development of laboratory information systems in the late 1970s and early 1980s. Changes on the horizon in healthcare and clinical laboratory service that affect the delivery of laboratory results include the increasing age of the population in North America, the implementation of the Balanced Budget Act (1997), and the creation of disease management companies. Major technology drivers include outcomes optimization and phenotypically targeted drugs. Constant cost pressures in the clinical laboratory have forced diagnostic manufacturers into less than optimal profitability states. Laboratory automation can be a tool for the improvement of laboratory services and may decrease costs. The key to improvement of laboratory services is implementation of the correct automation technology. The design of this technology should be driven by required functionality. Automation design issues should be centered on the understanding of the laboratory and its relationship to healthcare delivery and the business and operational processes in the clinical laboratory. Automation design philosophy has evolved from a hardware-based approach to a software-based approach. Process control software to support repeat testing, reflex testing, and transportation management, and overall computer-integrated manufacturing approaches to laboratory automation implementation are rapidly expanding areas. It is clear that hardware and software are functionally interdependent and that the interface between the laboratory automation system and the laboratory information system is a key component. The cost-effectiveness of automation solutions suggested by vendors, however, has been difficult to evaluate because the number of automation installations are few and the precision with which operational data have been collected to determine payback is suboptimal. The trend in automation has moved from total laboratory automation to a

  14. Engineering Mathematical Analysis Method for Productivity Rate in Linear Arrangement Serial Structure Automated Flow Assembly Line

    Directory of Open Access Journals (Sweden)

    Tan Chan Sin

    2015-01-01

    Full Text Available Productivity rate (Q or production rate is one of the important indicator criteria for industrial engineer to improve the system and finish good output in production or assembly line. Mathematical and statistical analysis method is required to be applied for productivity rate in industry visual overviews of the failure factors and further improvement within the production line especially for automated flow line since it is complicated. Mathematical model of productivity rate in linear arrangement serial structure automated flow line with different failure rate and bottleneck machining time parameters becomes the basic model for this productivity analysis. This paper presents the engineering mathematical analysis method which is applied in an automotive company which possesses automated flow assembly line in final assembly line to produce motorcycle in Malaysia. DCAS engineering and mathematical analysis method that consists of four stages known as data collection, calculation and comparison, analysis, and sustainable improvement is used to analyze productivity in automated flow assembly line based on particular mathematical model. Variety of failure rate that causes loss of productivity and bottleneck machining time is shown specifically in mathematic figure and presents the sustainable solution for productivity improvement for this final assembly automated flow line.

  15. A novel method to determine simultaneously methane production during in vitro gas production using fully automated equipment

    NARCIS (Netherlands)

    Pellikaan, W.F.; Hendriks, W.H.; Uwimanaa, G.; Bongers, L.J.G.M.; Becker, P.M.; Cone, J.W.

    2011-01-01

    An adaptation of fully automated gas production equipment was tested for its ability to simultaneously measure methane and total gas. The simultaneous measurement of gas production and gas composition was not possible using fully automated equipment, as the bottles should be kept closed during the

  16. Mobile Image Ratiometry: A New Method for Instantaneous Analysis of Rapid Test Strips

    OpenAIRE

    Donald C. Cooper; Bryan Callahan; Phil Callahan; Lee Burnett

    2012-01-01

    Here we describe Mobile Image Ratiometry (MIR), a new method for the automated quantification of standardized rapid immunoassay strips using consumer-based mobile smartphone and tablet cameras. To demonstrate MIR we developed a standardized method using rapid immunotest strips directed against cocaine (COC) and its major metabolite, benzoylecgonine (BE). We performed image analysis of three brands of commercially available dye-conjugated anti-COC/BE antibody test strips in response to three d...

  17. Automated reactivity anomaly surveillance in the Fast Flux Test Facility

    International Nuclear Information System (INIS)

    Knutson, B.J.; Harris, R.A.; Honeyman, D.J.; Shook, A.T.; Krohn, C.N.

    1985-01-01

    The automated technique for monitoring core reactivity during power operation used at the Fast Flux Test Facility (FFTF) is described. This technique relies on comparing predicted to measured rod positions to detect any anomalous (or unpredicted) core reactivity changes. It is implemented on the Plant Data System (PDS) computer and, thus, provides rapid indication of any abnormal core conditions. The prediction algorithms use thermal-hydraulic, control rod position and neutron flux sensor information to predict the core reactivity state

  18. Remote systems and automation in radioactive waste package handling

    International Nuclear Information System (INIS)

    Gneiting, B.C.; Hayward, M.L.

    1987-01-01

    A proof-of-principle test was conducted at the Hanford Engineering Development Laboratory (HEDL) to demonstrate the feasibility of performing cask receiving and unloading operations in a remote and partially automated manner. This development testing showed feasibility of performing critical cask receipt, preparation, and unloading operations from a single control station using remote controls and indirect viewing. Using robotics and remote automation in a cask handling system can result in lower personnel exposure levels and cask turnaround times while maintaining operational flexibility. An automated cask handling system presents a flexible state-of-the-art, cost effective alternative solution to hands-on methods that have been used in the past. 7 refs., 13 figs

  19. Comparison of manual versus automated data collection method for an evidence-based nursing practice study.

    Science.gov (United States)

    Byrne, M D; Jordan, T R; Welle, T

    2013-01-01

    The objective of this study was to investigate and improve the use of automated data collection procedures for nursing research and quality assurance. A descriptive, correlational study analyzed 44 orthopedic surgical patients who were part of an evidence-based practice (EBP) project examining post-operative oxygen therapy at a Midwestern hospital. The automation work attempted to replicate a manually-collected data set from the EBP project. Automation was successful in replicating data collection for study data elements that were available in the clinical data repository. The automation procedures identified 32 "false negative" patients who met the inclusion criteria described in the EBP project but were not selected during the manual data collection. Automating data collection for certain data elements, such as oxygen saturation, proved challenging because of workflow and practice variations and the reliance on disparate sources for data abstraction. Automation also revealed instances of human error including computational and transcription errors as well as incomplete selection of eligible patients. Automated data collection for analysis of nursing-specific phenomenon is potentially superior to manual data collection methods. Creation of automated reports and analysis may require initial up-front investment with collaboration between clinicians, researchers and information technology specialists who can manage the ambiguities and challenges of research and quality assurance work in healthcare.

  20. Automated corrosion fatigue crack growth testing in pressurized water environments

    International Nuclear Information System (INIS)

    Ceschini, L.J.; Liaw, P.K.; Rudd, G.E.; Logsdon, W.A.

    1984-01-01

    This paper describes in detail a novel approach to construct a test facility for developing corrosion fatigue crack growth rate (FCGR) properties in aggressive environments. The environment studied is that of a pressurized water reactor (PWR) at 288 0 C (550 0 F) and 13.8 MPa (200 psig). To expedite data generation, each chamber was designed to accommodate two test specimens. A common water recirculation and pressurization system was employed to service two test chambers. Thus, four fatigue crack propagation rate tests could be conducted simultaneously in the pressurized water environment. The data analysis was automated to minimize the typically high labor costs associated with corrosion fatigue crack propagation testing. Verification FCGR tests conducted on an ASTM A469 rotor steel in a room temperature air environment as well as actual PWR environment FCGR tests performed on an ASTM A533 Grade B Class 2 pressure vessel steel demonstrated that the dual specimen test facility is an excellent system for developing the FCGR properties of materials in adverse environments

  1. Automated Low-Cost Smartphone-Based Lateral Flow Saliva Test Reader for Drugs-of-Abuse Detection

    Directory of Open Access Journals (Sweden)

    Adrian Carrio

    2015-11-01

    Full Text Available Lateral flow assay tests are nowadays becoming powerful, low-cost diagnostic tools. Obtaining a result is usually subject to visual interpretation of colored areas on the test by a human operator, introducing subjectivity and the possibility of errors in the extraction of the results. While automated test readers providing a result-consistent solution are widely available, they usually lack portability. In this paper, we present a smartphone-based automated reader for drug-of-abuse lateral flow assay tests, consisting of an inexpensive light box and a smartphone device. Test images captured with the smartphone camera are processed in the device using computer vision and machine learning techniques to perform automatic extraction of the results. A deep validation of the system has been carried out showing the high accuracy of the system. The proposed approach, applicable to any line-based or color-based lateral flow test in the market, effectively reduces the manufacturing costs of the reader and makes it portable and massively available while providing accurate, reliable results.

  2. Automated Low-Cost Smartphone-Based Lateral Flow Saliva Test Reader for Drugs-of-Abuse Detection.

    Science.gov (United States)

    Carrio, Adrian; Sampedro, Carlos; Sanchez-Lopez, Jose Luis; Pimienta, Miguel; Campoy, Pascual

    2015-11-24

    Lateral flow assay tests are nowadays becoming powerful, low-cost diagnostic tools. Obtaining a result is usually subject to visual interpretation of colored areas on the test by a human operator, introducing subjectivity and the possibility of errors in the extraction of the results. While automated test readers providing a result-consistent solution are widely available, they usually lack portability. In this paper, we present a smartphone-based automated reader for drug-of-abuse lateral flow assay tests, consisting of an inexpensive light box and a smartphone device. Test images captured with the smartphone camera are processed in the device using computer vision and machine learning techniques to perform automatic extraction of the results. A deep validation of the system has been carried out showing the high accuracy of the system. The proposed approach, applicable to any line-based or color-based lateral flow test in the market, effectively reduces the manufacturing costs of the reader and makes it portable and massively available while providing accurate, reliable results.

  3. New clinical validation method for automated sphygmomanometer: a proposal by Japan ISO-WG for sphygmomanometer standard.

    Science.gov (United States)

    Shirasaki, Osamu; Asou, Yosuke; Takahashi, Yukio

    2007-12-01

    Owing to fast or stepwise cuff deflation, or measuring at places other than the upper arm, the clinical accuracy of most recent automated sphygmomanometers (auto-BPMs) cannot be validated by one-arm simultaneous comparison, which would be the only accurate validation method based on auscultation. Two main alternative methods are provided by current standards, that is, two-arm simultaneous comparison (method 1) and one-arm sequential comparison (method 2); however, the accuracy of these validation methods might not be sufficient to compensate for the suspicious accuracy in lateral blood pressure (BP) differences (LD) and/or BP variations (BPV) between the device and reference readings. Thus, the Japan ISO-WG for sphygmomanometer standards has been studying a new method that might improve validation accuracy (method 3). The purpose of this study is to determine the appropriateness of method 3 by comparing immunity to LD and BPV with those of the current validation methods (methods 1 and 2). The validation accuracy of the above three methods was assessed in human participants [N=120, 45+/-15.3 years (mean+/-SD)]. An oscillometric automated monitor, Omron HEM-762, was used as the tested device. When compared with the others, methods 1 and 3 showed a smaller intra-individual standard deviation of device error (SD1), suggesting their higher reproducibility of validation. The SD1 by method 2 (P=0.004) significantly correlated with the participant's BP, supporting our hypothesis that the increased SD of device error by method 2 is at least partially caused by essential BPV. Method 3 showed a significantly (P=0.0044) smaller interparticipant SD of device error (SD2), suggesting its higher interparticipant consistency of validation. Among the methods of validation of the clinical accuracy of auto-BPMs, method 3, which showed the highest reproducibility and highest interparticipant consistency, can be proposed as being the most appropriate.

  4. Automated drumlin shape and volume estimation using high resolution LiDAR imagery (Curvature Based Relief Separation): A test from the Wadena Drumlin Field, Minnesota

    Science.gov (United States)

    Yu, Peter; Eyles, Nick; Sookhan, Shane

    2015-10-01

    Resolving the origin(s) of drumlins and related megaridges in areas of megascale glacial lineations (MSGL) left by paleo-ice sheets is critical to understanding how ancient ice sheets interacted with their sediment beds. MSGL is now linked with fast-flowing ice streams but there is a broad range of erosional and depositional models. Further progress is reliant on constraining fluxes of subglacial sediment at the ice sheet base which in turn is dependent on morphological data such as landform shape and elongation and most importantly landform volume. Past practice in determining shape has employed a broad range of geomorphological methods from strictly visualisation techniques to more complex semi-automated and automated drumlin extraction methods. This paper reviews and builds on currently available visualisation, semi-automated and automated extraction methods and presents a new, Curvature Based Relief Separation (CBRS) technique; for drumlin mapping. This uses curvature analysis to generate a base level from which topography can be normalized and drumlin volume can be derived. This methodology is tested using a high resolution (3 m) LiDAR elevation dataset from the Wadena Drumlin Field, Minnesota, USA, which was constructed by the Wadena Lobe of the Laurentide Ice Sheet ca. 20,000 years ago and which as a whole contains 2000 drumlins across an area of 7500 km2. This analysis demonstrates that CBRS provides an objective and robust procedure for automated drumlin extraction. There is strong agreement with manually selected landforms but the method is also capable of resolving features that were not detectable manually thereby considerably expanding the known population of streamlined landforms. CBRS provides an effective automatic method for visualisation of large areas of the streamlined beds of former ice sheets and for modelling sediment fluxes below ice sheets.

  5. Computational Testing for Automated Preprocessing 2: Practical Demonstration of a System for Scientific Data-Processing Workflow Management for High-Volume EEG.

    Science.gov (United States)

    Cowley, Benjamin U; Korpela, Jussi

    2018-01-01

    Existing tools for the preprocessing of EEG data provide a large choice of methods to suitably prepare and analyse a given dataset. Yet it remains a challenge for the average user to integrate methods for batch processing of the increasingly large datasets of modern research, and compare methods to choose an optimal approach across the many possible parameter configurations. Additionally, many tools still require a high degree of manual decision making for, e.g., the classification of artifacts in channels, epochs or segments. This introduces extra subjectivity, is slow, and is not reproducible. Batching and well-designed automation can help to regularize EEG preprocessing, and thus reduce human effort, subjectivity, and consequent error. The Computational Testing for Automated Preprocessing (CTAP) toolbox facilitates: (i) batch processing that is easy for experts and novices alike; (ii) testing and comparison of preprocessing methods. Here we demonstrate the application of CTAP to high-resolution EEG data in three modes of use. First, a linear processing pipeline with mostly default parameters illustrates ease-of-use for naive users. Second, a branching pipeline illustrates CTAP's support for comparison of competing methods. Third, a pipeline with built-in parameter-sweeping illustrates CTAP's capability to support data-driven method parameterization. CTAP extends the existing functions and data structure from the well-known EEGLAB toolbox, based on Matlab, and produces extensive quality control outputs. CTAP is available under MIT open-source licence from https://github.com/bwrc/ctap.

  6. Sensors and Automated Analyzers for Radionuclides

    International Nuclear Information System (INIS)

    Grate, Jay W.; Egorov, Oleg B.

    2003-01-01

    The production of nuclear weapons materials has generated large quantities of nuclear waste and significant environmental contamination. We have developed new, rapid, automated methods for determination of radionuclides using sequential injection methodologies to automate extraction chromatographic separations, with on-line flow-through scintillation counting for real time detection. This work has progressed in two main areas: radionuclide sensors for water monitoring and automated radiochemical analyzers for monitoring nuclear waste processing operations. Radionuclide sensors have been developed that collect and concentrate radionuclides in preconcentrating minicolumns with dual functionality: chemical selectivity for radionuclide capture and scintillation for signal output. These sensors can detect pertechnetate to below regulatory levels and have been engineered into a prototype for field testing. A fully automated process monitor has been developed for total technetium in nuclear waste streams. This instrument performs sample acidification, speciation adjustment, separation and detection in fifteen minutes or less

  7. Learning About Cockpit Automation: From Piston Trainer to Jet Transport

    Science.gov (United States)

    Casner, Stephen M.

    2003-01-01

    Two experiments explored the idea of providing cockpit automation training to airline-bound student pilots using cockpit automation equipment commonly found in small training airplanes. In a first experiment, pilots mastered a set of tasks and maneuvers using a GPS navigation computer, autopilot, and flight director system installed in a small training airplane Students were then tested on their ability to complete a similar set of tasks using the cockpit automation system found in a popular jet transport aircraft. Pilot were able to successfully complete 77% of all tasks in the jet transport on their first attempt. An analysis of a control group suggests that the pilot's success was attributable to the application of automation principles they had learned in the small airplane. A second experiment looked at two different ways of delivering small-aeroplane cockpit automation training: a self-study method, and a dual instruction method. The results showed a slight advantage for the self-study method. Overall, the results of the two studies cast a strong vote for the incorporation of cockpit automation training in curricula designed for pilot who will later transition to the jet fleet.

  8. National SCADA Test Bed Substation Automation Evaluation Report

    Energy Technology Data Exchange (ETDEWEB)

    Kenneth Barnes; Briam Johnson

    2009-10-01

    Increased awareness of the potential for cyber attack has recently resulted in improved cyber security practices associated with the electrical power grid. However, the level of practical understanding and deployment of cyber security practices has not been evenly applied across all business sectors. Much of the focus has been centered on information technology business centers and control rooms. This report explores the current level of substation automation, communication, and cyber security protection deployed in electrical substations throughout existing utilities in the United States. This report documents the evaluation of substation automation implementation and associated vulnerabilities. This evaluation used research conducted by Newton-Evans Research Company for some of its observations and results. The Newton Evans Report aided in the determination of what is the state of substation automation in North American electric utilities. Idaho National Laboratory cyber security experts aided in the determination of what cyber vulnerabilities may pose a threat to electrical substations. This report includes cyber vulnerabilities as well as recommended mitigations. It also describes specific cyber issues found in typical substation automation configurations within the electric utility industry. The evaluation report was performed over a 5-month period starting in October 2008

  9. An independent evaluation of a new method for automated interpretation of lung scintigrams using artificial neural networks

    International Nuclear Information System (INIS)

    Holst, H.; Jaerund, A.; Evander, E.; Taegil, K.; Edenbrandt, L.; Maare, K.; Aastroem, K.; Ohlsson, M.

    2001-01-01

    The purpose of this study was to evaluate a new automated method for the interpretation of lung perfusion scintigrams using patients from a hospital other than that where the method was developed, and then to compare the performance of the technique against that of experienced physicians. A total of 1,087 scintigrams from patients with suspected pulmonary embolism comprised the training group. The test group consisted of scintigrams from 140 patients collected in a hospital different to that from which the training group had been drawn. An artificial neural network was trained using 18 automatically obtained features from each set of perfusion scintigrams. The image processing techniques included alignment to templates, construction of quotient images based on the perfusion/template images, and finally calculation of features describing segmental perfusion defects in the quotient images. The templates represented lungs of normal size and shape without any pathological changes. The performance of the neural network was compared with that of three experienced physicians who read the same test scintigrams according to the modified PIOPED criteria using, in addition to perfusion images, ventilation images when available and chest radiographs for all patients. Performances were measured as area under the receiver operating characteristic curve. The performance of the neural network evaluated in the test group was 0.88 (95% confidence limits 0.81-0.94). The performance of the three experienced experts was in the range 0.87-0.93 when using the perfusion images, chest radiographs and ventilation images when available. Perfusion scintigrams can be interpreted regarding the diagnosis of pulmonary embolism by the use of an automated method also in a hospital other than that where it was developed. The performance of this method is similar to that of experienced physicians even though the physicians, in addition to perfusion images, also had access to ventilation images for

  10. Using microwave Doppler radar in automated manufacturing applications

    Science.gov (United States)

    Smith, Gregory C.

    Since the beginning of the Industrial Revolution, manufacturers worldwide have used automation to improve productivity, gain market share, and meet growing or changing consumer demand for manufactured products. To stimulate further industrial productivity, manufacturers need more advanced automation technologies: "smart" part handling systems, automated assembly machines, CNC machine tools, and industrial robots that use new sensor technologies, advanced control systems, and intelligent decision-making algorithms to "see," "hear," "feel," and "think" at the levels needed to handle complex manufacturing tasks without human intervention. The investigator's dissertation offers three methods that could help make "smart" CNC machine tools and industrial robots possible: (1) A method for detecting acoustic emission using a microwave Doppler radar detector, (2) A method for detecting tool wear on a CNC lathe using a Doppler radar detector, and (3) An online non-contact method for detecting industrial robot position errors using a microwave Doppler radar motion detector. The dissertation studies indicate that microwave Doppler radar could be quite useful in automated manufacturing applications. In particular, the methods developed may help solve two difficult problems that hinder further progress in automating manufacturing processes: (1) Automating metal-cutting operations on CNC machine tools by providing a reliable non-contact method for detecting tool wear, and (2) Fully automating robotic manufacturing tasks by providing a reliable low-cost non-contact method for detecting on-line position errors. In addition, the studies offer a general non-contact method for detecting acoustic emission that may be useful in many other manufacturing and non-manufacturing areas, as well (e.g., monitoring and nondestructively testing structures, materials, manufacturing processes, and devices). By advancing the state of the art in manufacturing automation, the studies may help

  11. Reproducibility of Automated Voice Range Profiles, a Systematic Literature Review

    DEFF Research Database (Denmark)

    Printz, Trine; Rosenberg, Tine; Godballe, Christian

    2018-01-01

    literature on test-retest accuracy of the automated voice range profile assessment. Study design: Systematic review. Data sources: PubMed, Scopus, Cochrane Library, ComDisDome, Embase, and CINAHL (EBSCO). Methods: We conducted a systematic literature search of six databases from 1983 to 2016. The following......Objective: Reliable voice range profiles are of great importance when measuring effects and side effects from surgery affecting voice capacity. Automated recording systems are increasingly used, but the reproducibility of results is uncertain. Our objective was to identify and review the existing...... keywords were used: phonetogram, voice range profile, and acoustic voice analysis. Inclusion criteria were automated recording procedure, healthy voices, and no intervention between test and retest. Test-retest values concerning fundamental frequency and voice intensity were reviewed. Results: Of 483...

  12. Operational tests of a device with an elevator for automated outlet of heat for heating

    Energy Technology Data Exchange (ETDEWEB)

    Zinger, N.M.; Belevich, A.I.; Burd, A.L.; Krivitskiy, V.I.; Lokshin, L.S.

    1983-01-01

    The results are presented of operational tests of series produced jet pumps. The field of use of an automated elevator is determined and recommendations for increasing its operational qualities are given.

  13. Validation of commercially available automated canine-specific immunoturbidimetric method for measuring canine C-reactive protein

    DEFF Research Database (Denmark)

    Hillström, Anna; Hagman, Ragnvi; Tvedten, Harold

    2014-01-01

    BACKGROUND: Measurement of C-reactive protein (CRP) is used for diagnosing and monitoring systemic inflammatory disease in canine patients. An automated human immunoturbidimetric assay has been validated for measuring canine CRP, but cross-reactivity with canine CRP is unpredictable. OBJECTIVE......: The purpose of the study was to validate a new automated canine-specific immunoturbidimetric CRP method (Gentian cCRP). METHODS: Studies of imprecision, accuracy, prozone effect, interference, limit of quantification, and stability under different storage conditions were performed. The new method was compared...... with a human CRP assay previously validated for canine CRP determination. Samples from 40 healthy dogs were analyzed to establish a reference interval. RESULTS: Total imprecision was

  14. Virtual automation.

    Science.gov (United States)

    Casis, E; Garrido, A; Uranga, B; Vives, A; Zufiaurre, C

    2001-01-01

    Total laboratory automation (TLA) can be substituted in mid-size laboratories by a computer sample workflow control (virtual automation). Such a solution has been implemented in our laboratory using PSM, software developed in cooperation with Roche Diagnostics (Barcelona, Spain), to this purpose. This software is connected to the online analyzers and to the laboratory information system and is able to control and direct the samples working as an intermediate station. The only difference with TLA is the replacement of transport belts by personnel of the laboratory. The implementation of this virtual automation system has allowed us the achievement of the main advantages of TLA: workload increase (64%) with reduction in the cost per test (43%), significant reduction in the number of biochemistry primary tubes (from 8 to 2), less aliquoting (from 600 to 100 samples/day), automation of functional testing, drastic reduction of preanalytical errors (from 11.7 to 0.4% of the tubes) and better total response time for both inpatients (from up to 48 hours to up to 4 hours) and outpatients (from up to 10 days to up to 48 hours). As an additional advantage, virtual automation could be implemented without hardware investment and significant headcount reduction (15% in our lab).

  15. Evaluation of Oxidative Stress and Using a Novel Automated Method For Measurement of Total Antioxidant Status in Preeclampsia

    Directory of Open Access Journals (Sweden)

    Ebru Kale

    2006-04-01

    CONCLUSIONS: Our findings suggest that preeclampsia is related with enhanced lipid peroxidation and decreased total antioxidant response before delivery and these parameters may be related at least partly to the pathogenesis of preeclampsia. Decreased lipid peroxidation and increased total antioxidant response after delivery may suggest recov ery of preeclampsia and using a simple, rapid and reliable automated method f acilitates to ev aluate and follow up of the lev els of oxidativ e stress in preeclampsia and this novel method may be used as a routine test in clinical practice while managing preeclampsia

  16. Automated Scoring for the "TOEFL Junior"® Comprehensive Writing and Speaking Test. Research Report. ETS RR-15-09

    Science.gov (United States)

    Evanini, Keelan; Heilman, Michael; Wang, Xinhao; Blanchard, Daniel

    2015-01-01

    This report describes the initial automated scoring results that were obtained using the constructed responses from the Writing and Speaking sections of the pilot forms of the "TOEFL Junior"® Comprehensive test administered in late 2011. For all of the items except one (the edit item in the Writing section), existing automated scoring…

  17. A new automated assessment method for contrast-detail images by applying support vector machine and its robustness to nonlinear image processing.

    Science.gov (United States)

    Takei, Takaaki; Ikeda, Mitsuru; Imai, Kuniharu; Yamauchi-Kawaura, Chiyo; Kato, Katsuhiko; Isoda, Haruo

    2013-09-01

    The automated contrast-detail (C-D) analysis methods developed so-far cannot be expected to work well on images processed with nonlinear methods, such as noise reduction methods. Therefore, we have devised a new automated C-D analysis method by applying support vector machine (SVM), and tested for its robustness to nonlinear image processing. We acquired the CDRAD (a commercially available C-D test object) images at a tube voltage of 120 kV and a milliampere-second product (mAs) of 0.5-5.0. A partial diffusion equation based technique was used as noise reduction method. Three radiologists and three university students participated in the observer performance study. The training data for our SVM method was the classification data scored by the one radiologist for the CDRAD images acquired at 1.6 and 3.2 mAs and their noise-reduced images. We also compared the performance of our SVM method with the CDRAD Analyser algorithm. The mean C-D diagrams (that is a plot of the mean of the smallest visible hole diameter vs. hole depth) obtained from our devised SVM method agreed well with the ones averaged across the six human observers for both original and noise-reduced CDRAD images, whereas the mean C-D diagrams from the CDRAD Analyser algorithm disagreed with the ones from the human observers for both original and noise-reduced CDRAD images. In conclusion, our proposed SVM method for C-D analysis will work well for the images processed with the non-linear noise reduction method as well as for the original radiographic images.

  18. Highly selective coulometric method and equipment for the automated determination of plutonium

    International Nuclear Information System (INIS)

    Jackson, D.D.; Hollen, R.M.; Roensch, F.R.; Rein, J.E.

    1977-01-01

    A highly selective, controlled-potential coulometric method has been developed for the determination of plutonium. An automated instrument, consisting of commercial electronic components under control of a programmable calculator, is being constructed. Half-cell potentials and interfering anions are listed

  19. Factors that influence standard automated perimetry test results in glaucoma: test reliability, technician experience, time of day, and season.

    Science.gov (United States)

    Junoy Montolio, Francisco G; Wesselink, Christiaan; Gordijn, Marijke; Jansonius, Nomdo M

    2012-10-09

    To determine the influence of several factors on standard automated perimetry test results in glaucoma. Longitudinal Humphrey field analyzer 30-2 Swedish interactive threshold algorithm data from 160 eyes of 160 glaucoma patients were used. The influence of technician experience, time of day, and season on the mean deviation (MD) was determined by performing linear regression analysis of MD against time on a series of visual fields and subsequently performing a multiple linear regression analysis with the MD residuals as dependent variable and the factors mentioned above as independent variables. Analyses were performed with and without adjustment for the test reliability (fixation losses and false-positive and false-negative answers) and with and without stratification according to disease stage (baseline MD). Mean follow-up was 9.4 years, with on average 10.8 tests per patient. Technician experience, time of day, and season were associated with the MD. Approximately 0.2 dB lower MD values were found for inexperienced technicians (P Technician experience, time of day, season, and the percentage of false-positive answers have a significant influence on the MD of standard automated perimetry.

  20. Cooling method with automated seasonal freeze protection

    Science.gov (United States)

    Cambell, Levi; Chu, Richard; David, Milnes; Ellsworth, Jr, Michael; Iyengar, Madhusudan; Simons, Robert; Singh, Prabjit; Zhang, Jing

    2016-05-31

    An automated multi-fluid cooling method is provided for cooling an electronic component(s). The method includes obtaining a coolant loop, and providing a coolant tank, multiple valves, and a controller. The coolant loop is at least partially exposed to outdoor ambient air temperature(s) during normal operation, and the coolant tank includes first and second reservoirs containing first and second fluids, respectively. The first fluid freezes at a lower temperature than the second, the second fluid has superior cooling properties compared with the first, and the two fluids are soluble. The multiple valves are controllable to selectively couple the first or second fluid into the coolant in the coolant loop, wherein the coolant includes at least the second fluid. The controller automatically controls the valves to vary first fluid concentration level in the coolant loop based on historical, current, or anticipated outdoor air ambient temperature(s) for a time of year.

  1. A novel automated alternating current biosusceptometry method to characterization of controlled-release magnetic floating tablets of metronidazole.

    Science.gov (United States)

    Ferrari, Priscileila Colerato; dos Santos Grossklauss, Dany Bruno Borella; Alvarez, Matheus; Paixão, Fabiano Carlos; Andreis, Uilian; Crispim, Alexandre Giordano; de Castro, Ana Dóris; Evangelista, Raul Cesar; de Arruda Miranda, José Ricardo

    2014-08-01

    Alternating Current Biosusceptometry is a magnetically method used to characterize drug delivery systems. This work presents a system composed by an automated ACB sensor to acquire magnetic images of floating tablets. The purpose of this study was to use an automated Alternating Current Biosusceptometry (ACB) to characterize magnetic floating tablets for controlled drug delivery. Floating tablets were prepared with hydroxypropyl methylcellulose (HPMC) as hydrophilic gel material, sodium bicarbonate as gas-generating agent and ferrite as magnetic marker. ACB was used to characterize the floating lag time and the tablet hydration rate, by quantification of the magnetic images to magnetic area. Besides the buoyancy, the floating tablets were evaluated for weight uniformity, hardness, swelling and in vitro drug release. The optimized tablets were prepared with equal amounts of HPMC and ferrite, and began to float within 4 min, maintaining the flotation during more than 24 h. The data of all physical parameters lied within the pharmacopeial limits. Drug release at 24 h was about 40%. The ACB results showed that this study provided a new approach for in vitro investigation of controlled-release dosage forms. Moreover, using automated ACB will also be possible to test these parameters in humans allowing to establish an in vitro.in vivo correlation (IVIVC).

  2. Residual stress measurement by X-ray diffraction with the Gaussian curve method and its automation

    International Nuclear Information System (INIS)

    Kurita, M.

    1987-01-01

    X-ray technique with the Gaussian curve method and its automation are described for rapid and nondestructive measurement of residual stress. A simplified equation for measuring the stress by the Gaussian curve method is derived because in its previous form this method required laborious calculation. The residual stress can be measured in a few minutes, depending on materials, using an automated X-ray stress analyzer with a microcomputer which was developed in the laboratory. The residual stress distribution of a partially induction hardened and tempered (at 280 0 C) steel bar was measured with the Gaussian curve method. A sharp residual tensile stress peak of 182 MPa appeared right outside the hardened region at which fatigue failure is liable to occur

  3. Augmenting SCA project management and automation framework

    Science.gov (United States)

    Iyapparaja, M.; Sharma, Bhanupriya

    2017-11-01

    In our daily life we need to keep the records of the things in order to manage it in more efficient and proper way. Our Company manufactures semiconductor chips and sale it to the buyer. Sometimes it manufactures the entire product and sometimes partially and sometimes it sales the intermediary product obtained during manufacturing, so for the better management of the entire process there is a need to keep the track record of all the entity involved in it. Materials and Methods: Therefore to overcome with the problem the need raised to develop the framework for the maintenance of the project and for the automation testing. Project management framework provides an architecture which supports in managing the project by marinating the records of entire requirements, the test cases that were created for testing each unit of the software, defect raised from the past years. So through this the quality of the project can be maintained. Results: Automation framework provides the architecture which supports the development and implementation of the automation test script for the software testing process. Conclusion: For implementing project management framework the product of HP that is Application Lifecycle management is used which provides central repository to maintain the project.

  4. Specific Methods of Information Security for Nuclear Materials Control and Accounting Automate Systems

    Directory of Open Access Journals (Sweden)

    Konstantin Vyacheslavovich Ivanov

    2013-02-01

    Full Text Available The paper is devoted to specific methods of information security for nuclear materials control and accounting automate systems which is not required of OS and DBMS certifications and allowed to programs modification for clients specific without defenses modification. System ACCORD-2005 demonstrates the realization of this method.

  5. Development of Nuclear Power Plant Safety Evaluation Method for the Automation Algorithm Application

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seung Geun; Seong, Poong Hyun [KAIST, Daejeon (Korea, Republic of)

    2016-10-15

    It is commonly believed that replacing human operators to the automated system would guarantee greater efficiency, lower workloads, and fewer human error. Conventional machine learning techniques are considered as not capable to handle complex situations in NPP. Due to these kinds of issues, automation is not actively adopted although human error probability drastically increases during abnormal situations in NPP due to overload of information, high workload, and short time available for diagnosis. Recently, new machine learning techniques, which are known as ‘deep learning’ techniques have been actively applied to many fields, and the deep learning technique-based artificial intelligences (AIs) are showing better performance than conventional AIs. In 2015, deep Q-network (DQN) which is one of the deep learning techniques was developed and applied to train AI that automatically plays various Atari 2800 games, and this AI surpassed the human-level playing in many kind of games. Also in 2016, ‘Alpha-Go’, which was developed by ‘Google Deepmind’ based on deep learning technique to play the game of Go (i.e. Baduk), was defeated Se-dol Lee who is the World Go champion with score of 4:1. By the effort for reducing human error in NPPs, the ultimate goal of this study is the development of automation algorithm which can cover various situations in NPPs. As the first part, quantitative and real-time NPP safety evaluation method is being developed in order to provide the training criteria for automation algorithm. For that, EWS concept of medical field was adopted, and the applicability is investigated in this paper. Practically, the application of full automation (i.e. fully replaces human operators) may requires much more time for the validation and investigation of side-effects after the development of automation algorithm, and so the adoption in the form of full automation will take long time.

  6. Development of Nuclear Power Plant Safety Evaluation Method for the Automation Algorithm Application

    International Nuclear Information System (INIS)

    Kim, Seung Geun; Seong, Poong Hyun

    2016-01-01

    It is commonly believed that replacing human operators to the automated system would guarantee greater efficiency, lower workloads, and fewer human error. Conventional machine learning techniques are considered as not capable to handle complex situations in NPP. Due to these kinds of issues, automation is not actively adopted although human error probability drastically increases during abnormal situations in NPP due to overload of information, high workload, and short time available for diagnosis. Recently, new machine learning techniques, which are known as ‘deep learning’ techniques have been actively applied to many fields, and the deep learning technique-based artificial intelligences (AIs) are showing better performance than conventional AIs. In 2015, deep Q-network (DQN) which is one of the deep learning techniques was developed and applied to train AI that automatically plays various Atari 2800 games, and this AI surpassed the human-level playing in many kind of games. Also in 2016, ‘Alpha-Go’, which was developed by ‘Google Deepmind’ based on deep learning technique to play the game of Go (i.e. Baduk), was defeated Se-dol Lee who is the World Go champion with score of 4:1. By the effort for reducing human error in NPPs, the ultimate goal of this study is the development of automation algorithm which can cover various situations in NPPs. As the first part, quantitative and real-time NPP safety evaluation method is being developed in order to provide the training criteria for automation algorithm. For that, EWS concept of medical field was adopted, and the applicability is investigated in this paper. Practically, the application of full automation (i.e. fully replaces human operators) may requires much more time for the validation and investigation of side-effects after the development of automation algorithm, and so the adoption in the form of full automation will take long time

  7. Measurement of the total antioxidant potential in chronic obstructive pulmonary diseases with a novel automated method

    International Nuclear Information System (INIS)

    Ceylan, E.; Gencer, M.; Uzer, E.; Celik, H.

    2007-01-01

    To determine the oxidative and antioxidative status of plasma of patients with chronic obstructive pulmonary disease (COPD) and to compare these values with healthy smokers and healthy non-smokers control subjects using a more recently developed automated measurement method. This study involved 40 COPD patients, 25 healthy smokers, and 25 non-healthy smokers who attended the Chest Disease Outpatient Clinic in Harran University Research Hospital, Turkey between the period March 2006 and June 2006. We calculated the total antioxidant potential (TAOP) to determine the antioxidative status of plasma and we measured the total peroxide levels to determine the oxidative status of plasma. The TAOP of plasma was significantly lower in patients with COPD than in healthy smokers and healthy non-smokers (p< 0.001). In contrast, the mean total peroxide level of plasma was significantly higher in COPD patients than in healthy smokers and healthy non-smokers (p<0.001). We found a decreased in TAOP COPD patients using a simple, rapid and reliably automated colorimetric assay, which may suitable for use in routine clinical biochemistry laboratory and considerably facilitates the assessment of this useful clinical parameter. We suggest that this novel method may be used as a routine test to evaluate and follow-up the levels of oxidative stress in COPD. (author)

  8. A Comparison of Anti-Nuclear Antibody Quantification Using Automated Enzyme Immunoassays and Immunofluorescence Assays

    DEFF Research Database (Denmark)

    Baronaite, Renata; Engelhart, Merete; Mørk Hansen, Troels

    2014-01-01

    using IFA and automated EIA techniques. The IFA results generated by two independent laboratories were compared with the EIA results from antibodies against double-stranded DNA (dsDNA), from ANA screening, and from tests of the seven included subantigens. The final IFA and EIA results for 386 unique......, with Cohen's kappa value of 0.30 (95% confidence interval (CI) = 0.14-0.46), which decreased to 0.23 (95% CI = 0.06-0.40) when the results for dsDNA were omitted. The EIA method was less reliable for assessing nuclear and speckled reactivity patterns, whereas the IFA method presented difficulties detecting...... dsDNA and Ro activity. The automated EIA method was performed in a similar way to the conventional IFA method using HEp-2 cells; thus, automated EIA may be used as a screening test....

  9. Unmet needs in automated cytogenetics

    International Nuclear Information System (INIS)

    Bender, M.A.

    1976-01-01

    Though some, at least, of the goals of automation systems for analysis of clinical cytogenetic material seem either at hand, like automatic metaphase finding, or at least likely to be met in the near future, like operator-assisted semi-automatic analysis of banded metaphase spreads, important areas of cytogenetic analsis, most importantly the determination of chromosomal aberration frequencies in populations of cells or in samples of cells from people exposed to environmental mutagens, await practical methods of automation. Important as are the clinical diagnostic applications, it is apparent that increasing concern over the clastogenic effects of the multitude of potentially clastogenic chemical and physical agents to which human populations are being increasingly exposed, and the resulting emergence of extensive cytogenetic testing protocols, makes the development of automation not only economically feasible but almost mandatory. The nature of the problems involved, and acutal of possible approaches to their solution, are discussed

  10. The Space Station Module Power Management and Distribution automation test bed

    Science.gov (United States)

    Lollar, Louis F.

    1991-01-01

    The Space Station Module Power Management And Distribution (SSM/PMAD) automation test bed project was begun at NASA/Marshall Space Flight Center (MSFC) in the mid-1980s to develop an autonomous, user-supportive power management and distribution test bed simulating the Space Station Freedom Hab/Lab modules. As the test bed has matured, many new technologies and projects have been added. The author focuses on three primary areas. The first area is the overall accomplishments of the test bed itself. These include a much-improved user interface, a more efficient expert system scheduler, improved communication among the three expert systems, and initial work on adding intermediate levels of autonomy. The second area is the addition of a more realistic power source to the SSM/PMAD test bed; this project is called the Large Autonomous Spacecraft Electrical Power System (LASEPS). The third area is the completion of a virtual link between the SSM/PMAD test bed at MSFC and the Autonomous Power Expert at Lewis Research Center.

  11. Design and implementation of an automated email notification system for results of tests pending at discharge.

    Science.gov (United States)

    Dalal, Anuj K; Schnipper, Jeffrey L; Poon, Eric G; Williams, Deborah H; Rossi-Roh, Kathleen; Macleay, Allison; Liang, Catherine L; Nolido, Nyryan; Budris, Jonas; Bates, David W; Roy, Christopher L

    2012-01-01

    Physicians are often unaware of the results of tests pending at discharge (TPADs). The authors designed and implemented an automated system to notify the responsible inpatient physician of the finalized results of TPADs using secure, network email. The system coordinates a series of electronic events triggered by the discharge time stamp and sends an email to the identified discharging attending physician once finalized results are available. A carbon copy is sent to the primary care physicians in order to facilitate communication and the subsequent transfer of responsibility. Logic was incorporated to suppress selected tests and to limit notification volume. The system was activated for patients with TPADs discharged by randomly selected inpatient-attending physicians during a 6-month pilot. They received approximately 1.6 email notifications per discharged patient with TPADs. Eighty-four per cent of inpatient-attending physicians receiving automated email notifications stated that they were satisfied with the system in a brief survey (59% survey response rate). Automated email notification is a useful strategy for managing results of TPADs.

  12. Comparison and clinical utility evaluation of four multiple allergen simultaneous tests including two newly introduced fully automated analyzers

    Directory of Open Access Journals (Sweden)

    John Hoon Rim

    2016-04-01

    Full Text Available Background: We compared the diagnostic performances of two newly introduced fully automated multiple allergen simultaneous tests (MAST analyzers with two conventional MAST assays. Methods: The serum samples from a total of 53 and 104 patients were tested for food panels and inhalant panels, respectively, in four analyzers including AdvanSure AlloScreen (LG Life Science, Korea, AdvanSure Allostation Smart II (LG Life Science, PROTIA Allergy-Q (ProteomeTech, Korea, and RIDA Allergy Screen (R-Biopharm, Germany. We compared not only the total agreement percentages but also positive propensities among four analyzers. Results: Evaluation of AdvanSure Allostation Smart II as upgraded version of AdvanSure AlloScreen revealed good concordance with total agreement percentages of 93.0% and 92.2% in food and inhalant panel, respectively. Comparisons of AdvanSure Allostation Smart II or PROTIA Allergy-Q with RIDA Allergy Screen also showed good concordance performance with positive propensities of two new analyzers for common allergens (Dermatophagoides farina and Dermatophagoides pteronyssinus. The changes of cut-off level resulted in various total agreement percentage fluctuations among allergens by different analyzers, although current cut-off level of class 2 appeared to be generally suitable. Conclusions: AdvanSure Allostation Smart II and PROTIA Allergy-Q presented favorable agreement performances with RIDA Allergy Screen, although positive propensities were noticed in common allergens. Keywords: Multiple allergen simultaneous test, Automated analyzer

  13. Fully-automated computer-assisted method of CT brain scan analysis for the measurement of cerebrospinal fluid spaces and brain absorption density

    Energy Technology Data Exchange (ETDEWEB)

    Baldy, R.E.; Brindley, G.S.; Jacobson, R.R.; Reveley, M.A.; Lishman, W.A.; Ewusi-Mensah, I.; Turner, S.W.

    1986-03-01

    Computer-assisted methods of CT brain scan analysis offer considerable advantages over visual inspection, particularly in research; and several semi-automated methods are currently available. A new computer-assisted program is presented which provides fully automated processing of CT brain scans, depending on ''anatomical knowledge'' of where cerebrospinal fluid (CSF)-containing spaces are likely to lie. After identifying these regions of interest quantitative estimates are then provided of CSF content in each slice in cisterns, ventricles, Sylvian fissure and interhemispheric fissure. Separate measures are also provided of mean brain density in each slice. These estimates can be summated to provide total ventricular and total brain volumes. The program shows a high correlation with measures derived from mechanical planimetry and visual grading procedures, also when tested against a phantom brain of known ventricular volume. The advantages and limitations of the present program are discussed.

  14. Clinical evaluation of 64-slice CT assessment of global left ventricular function using automated cardiac phase selection

    International Nuclear Information System (INIS)

    Joemai, Raoul M.S.; Geleijns, Joemai; Veldkamp, Wouter J.H.; Kroft, Lucia J.M.

    2008-01-01

    Left ventricular (LV) function provides prognostic information regarding the morbidity and mortality of patients. An automated cardiac phase selection algorithm has the potential to support the assessment of LV function with computed tomography (CT). This algorithm is clinically evaluated for 64-slice cardiac CT. Examinations of twenty consecutive patients were selected. Electrocardiogram gated contrast-enhanced CT was performed. Reconstructions were performed using an automated and a manual method, followed by the determination of the global LV function. Significances were tested using 2-sided Student's t-tests. Reduction in post processing time and storage capacity were estimated. A slightly smaller mean end-systolic volume was found with the automated method (52±18 ml vs 54±17 ml, p=0.02, r=0.99). The mean LV ejection fraction was slightly larger with the automated method (65±8% vs 64±8%, p=0.004, r=0.99). The estimated reduction in post processing time was maximal 5 min per patient with a potential 80% data storage reduction. Results of the automated phase selection algorithm are similar to the manual method. The automated tool reduces post processing time, reconstruction time and transfer time. (author)

  15. A geometrically based method for automated radiosurgery planning

    International Nuclear Information System (INIS)

    Wagner, Thomas H.; Yi Taeil; Meeks, Sanford L.; Bova, Francis J.; Brechner, Beverly L.; Chen Yunmei; Buatti, John M.; Friedman, William A.; Foote, Kelly D.; Bouchet, Lionel G.

    2000-01-01

    Purpose: A geometrically based method of multiple isocenter linear accelerator radiosurgery treatment planning optimization was developed, based on a target's solid shape. Methods and Materials: Our method uses an edge detection process to determine the optimal sphere packing arrangement with which to cover the planning target. The sphere packing arrangement is converted into a radiosurgery treatment plan by substituting the isocenter locations and collimator sizes for the spheres. Results: This method is demonstrated on a set of 5 irregularly shaped phantom targets, as well as a set of 10 clinical example cases ranging from simple to very complex in planning difficulty. Using a prototype implementation of the method and standard dosimetric radiosurgery treatment planning tools, feasible treatment plans were developed for each target. The treatment plans generated for the phantom targets showed excellent dose conformity and acceptable dose homogeneity within the target volume. The algorithm was able to generate a radiosurgery plan conforming to the Radiation Therapy Oncology Group (RTOG) guidelines on radiosurgery for every clinical and phantom target examined. Conclusions: This automated planning method can serve as a valuable tool to assist treatment planners in rapidly and consistently designing conformal multiple isocenter radiosurgery treatment plans.

  16. Automating the simulator testing and data collection process

    Energy Technology Data Exchange (ETDEWEB)

    Magi, T.; Dimitri-Hakim, R. [L-3 Communications MAPPS Inc., Montreal, Quebec (Canada)

    2012-07-01

    Scenario-based training is a key process in the use of Full Scope Simulators (FSS) for operator training. Scenario-based training can be defined as any set of simulated plant operations performed with a specific training objective in mind. In order to meet this training objective, the ANSI/ANS-3.5-2009 standard requires that certain simulator training scenarios be tested to ensure that they reproduce the expected plant responses, that all plant procedures can be followed, and that scenario-based training objectives can be met. While malfunction testing provided a narrow view of the simulator performance revolving around the malfunction itself, scenario testing provides a broader, overall view. The concept of instructor validation of simulator scenarios to be used for training and evaluation, and oversight of simulator performance during the validation process, work hand-in-hand. This is where Scenario-Based Testing comes into play. With the description of Scenario-Based Testing (SBT) within Nuclear Energy Institute NEI 09-09 white paper and within the ANSI/ANS-3.5-2009 standard, the industry now has a way forward that reduces the regulatory uncertainty. Together, scenario-based testing and scenario-based training combine to produce better simulators which in turn can be used to more effectively and efficiently train new and existing power plant operators. However, they also impose a significant data gathering and analysis burden on FSS users. L-3 MAPPS Orchid Instructor Station (Orchid IS) facilitates this data gathering and analysis by providing features that automate this process with a simple, centralized, easy to use interface. (author)

  17. Automated diagnosis of myositis from muscle ultrasound: Exploring the use of machine learning and deep learning methods.

    Directory of Open Access Journals (Sweden)

    Philippe Burlina

    Full Text Available To evaluate the use of ultrasound coupled with machine learning (ML and deep learning (DL techniques for automated or semi-automated classification of myositis.Eighty subjects comprised of 19 with inclusion body myositis (IBM, 14 with polymyositis (PM, 14 with dermatomyositis (DM, and 33 normal (N subjects were included in this study, where 3214 muscle ultrasound images of 7 muscles (observed bilaterally were acquired. We considered three problems of classification including (A normal vs. affected (DM, PM, IBM; (B normal vs. IBM patients; and (C IBM vs. other types of myositis (DM or PM. We studied the use of an automated DL method using deep convolutional neural networks (DL-DCNNs for diagnostic classification and compared it with a semi-automated conventional ML method based on random forests (ML-RF and "engineered" features. We used the known clinical diagnosis as the gold standard for evaluating performance of muscle classification.The performance of the DL-DCNN method resulted in accuracies ± standard deviation of 76.2% ± 3.1% for problem (A, 86.6% ± 2.4% for (B and 74.8% ± 3.9% for (C, while the ML-RF method led to accuracies of 72.3% ± 3.3% for problem (A, 84.3% ± 2.3% for (B and 68.9% ± 2.5% for (C.This study demonstrates the application of machine learning methods for automatically or semi-automatically classifying inflammatory muscle disease using muscle ultrasound. Compared to the conventional random forest machine learning method used here, which has the drawback of requiring manual delineation of muscle/fat boundaries, DCNN-based classification by and large improved the accuracies in all classification problems while providing a fully automated approach to classification.

  18. Automated diagnosis of myositis from muscle ultrasound: Exploring the use of machine learning and deep learning methods.

    Science.gov (United States)

    Burlina, Philippe; Billings, Seth; Joshi, Neil; Albayda, Jemima

    2017-01-01

    To evaluate the use of ultrasound coupled with machine learning (ML) and deep learning (DL) techniques for automated or semi-automated classification of myositis. Eighty subjects comprised of 19 with inclusion body myositis (IBM), 14 with polymyositis (PM), 14 with dermatomyositis (DM), and 33 normal (N) subjects were included in this study, where 3214 muscle ultrasound images of 7 muscles (observed bilaterally) were acquired. We considered three problems of classification including (A) normal vs. affected (DM, PM, IBM); (B) normal vs. IBM patients; and (C) IBM vs. other types of myositis (DM or PM). We studied the use of an automated DL method using deep convolutional neural networks (DL-DCNNs) for diagnostic classification and compared it with a semi-automated conventional ML method based on random forests (ML-RF) and "engineered" features. We used the known clinical diagnosis as the gold standard for evaluating performance of muscle classification. The performance of the DL-DCNN method resulted in accuracies ± standard deviation of 76.2% ± 3.1% for problem (A), 86.6% ± 2.4% for (B) and 74.8% ± 3.9% for (C), while the ML-RF method led to accuracies of 72.3% ± 3.3% for problem (A), 84.3% ± 2.3% for (B) and 68.9% ± 2.5% for (C). This study demonstrates the application of machine learning methods for automatically or semi-automatically classifying inflammatory muscle disease using muscle ultrasound. Compared to the conventional random forest machine learning method used here, which has the drawback of requiring manual delineation of muscle/fat boundaries, DCNN-based classification by and large improved the accuracies in all classification problems while providing a fully automated approach to classification.

  19. [Automated measurement of distance vision based on the DIN strategy].

    Science.gov (United States)

    Effert, R; Steinmetz, H; Jansen, W; Rau, G; Reim, M

    1989-07-01

    A method for automated measurement of far vision is described which meets the test requirements laid down in the new DIN standards. The subject sits 5 m from a high-resolution monitor on which either Landolt rings or Snellen's types are generated by a computer. By moving a joystick the subject indicates to the computer whether he can see the critical detail (e.g., the direction of opening of the Landolt ring). Depending on the subject's input and the course of the test so far, the computer generates the next test symbol until the threshold criterion is reached. The sequence of presentation of the symbols and the threshold criterion are also in accordance with the DIN standard. Initial measurements of far vision using this automated system produced similar results to those obtained by conventional methods.

  20. JPLEX: Java Simplex Implementation with Branch-and-Bound Search for Automated Test Assembly

    Science.gov (United States)

    Park, Ryoungsun; Kim, Jiseon; Dodd, Barbara G.; Chung, Hyewon

    2011-01-01

    JPLEX, short for Java simPLEX, is an automated test assembly (ATA) program. It is a mixed integer linear programming (MILP) solver written in Java. It reads in a configuration file, solves the minimization problem, and produces an output file for postprocessing. It implements the simplex algorithm to create a fully relaxed solution and…

  1. Using Automated Essay Scores as an Anchor When Equating Constructed Response Writing Tests

    Science.gov (United States)

    Almond, Russell G.

    2014-01-01

    Assessments consisting of only a few extended constructed response items (essays) are not typically equated using anchor test designs as there are typically too few essay prompts in each form to allow for meaningful equating. This article explores the idea that output from an automated scoring program designed to measure writing fluency (a common…

  2. Automated Speech Rate Measurement in Dysarthria

    Science.gov (United States)

    Martens, Heidi; Dekens, Tomas; Van Nuffelen, Gwen; Latacz, Lukas; Verhelst, Werner; De Bodt, Marc

    2015-01-01

    Purpose: In this study, a new algorithm for automated determination of speech rate (SR) in dysarthric speech is evaluated. We investigated how reliably the algorithm calculates the SR of dysarthric speech samples when compared with calculation performed by speech-language pathologists. Method: The new algorithm was trained and tested using Dutch…

  3. Testing of a new prototype surgical stapler that automates the rollover sleeve technique for venous anastomoses

    OpenAIRE

    PATRICIA B CARROLL; WERVISTON DEFARIA; CARLOS GANDIA; MARIANA BERHO; EVANGELOS MISIAKOS; ANDREAS G TZAKIS

    2006-01-01

    The creation of successful vascular anastomoses is of primary importance in many surgical fields. Numerous attempts to automate this process have been made. These techniques have slowly gained acceptance, but their use is still limited. This report details feasibility testing of a new prototype stapler that automates the rollover sleeve technique for venous vascular anastomoses. Male and female mongrel dogs (n=7) (25-32 kg) were used. A segment of the right (n=5) or left (n=2) iliac vein was ...

  4. Breast Density Estimation with Fully Automated Volumetric Method: Comparison to Radiologists' Assessment by BI-RADS Categories.

    Science.gov (United States)

    Singh, Tulika; Sharma, Madhurima; Singla, Veenu; Khandelwal, Niranjan

    2016-01-01

    The objective of our study was to calculate mammographic breast density with a fully automated volumetric breast density measurement method and to compare it to breast imaging reporting and data system (BI-RADS) breast density categories assigned by two radiologists. A total of 476 full-field digital mammography examinations with standard mediolateral oblique and craniocaudal views were evaluated by two blinded radiologists and BI-RADS density categories were assigned. Using a fully automated software, mean fibroglandular tissue volume, mean breast volume, and mean volumetric breast density were calculated. Based on percentage volumetric breast density, a volumetric density grade was assigned from 1 to 4. The weighted overall kappa was 0.895 (almost perfect agreement) for the two radiologists' BI-RADS density estimates. A statistically significant difference was seen in mean volumetric breast density among the BI-RADS density categories. With increased BI-RADS density category, increase in mean volumetric breast density was also seen (P BI-RADS categories and volumetric density grading by fully automated software (ρ = 0.728, P BI-RADS density category by two observers showed fair agreement (κ = 0.398 and 0.388, respectively). In our study, a good correlation was seen between density grading using fully automated volumetric method and density grading using BI-RADS density categories assigned by the two radiologists. Thus, the fully automated volumetric method may be used to quantify breast density on routine mammography. Copyright © 2016 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  5. System and Method for Automated Rendezvous, Docking and Capture of Autonomous Underwater Vehicles

    Science.gov (United States)

    Stone, William C. (Inventor); Clark, Evan (Inventor); Richmond, Kristof (Inventor); Paulus, Jeremy (Inventor); Kapit, Jason (Inventor); Scully, Mark (Inventor); Kimball, Peter (Inventor)

    2018-01-01

    A system for automated rendezvous, docking, and capture of autonomous underwater vehicles at the conclusion of a mission comprising of comprised of a docking rod having lighted, pulsating (in both frequency and light intensity) series of LED light strips thereon, with the LEDs at a known spacing, and the autonomous underwater vehicle specially designed to detect and capture the docking rod and then be lifted structurally by a spherical end strop about which the vehicle can be pivoted and hoisted up (e.g., onto a ship). The method of recovery allows for very routine and reliable automated recovery of an unmanned underwater asset.

  6. Standard software for automated testing of infrared imagers, IRWindows, in practical applications

    Science.gov (United States)

    Irwin, Alan; Nicklin, Robert L.

    1998-08-01

    In the past, ad-hoc and manual testing of infrared images hasn't been a deterrent to the characterization of these systems due to the low volume of production and high ratio of skilled personnel to the quantity of units under test. However, with higher volume production, increasing numbers of development labs in emerging markets, and the push towards less expensive, faster development cycles, there is a strong need for standardized testing that is quickly configurable by test engineers, which can be run by less experienced test technicians, and which produce repeatable, accurate results. The IRWindowsTM system addresses these needs using a standard computing platform and existing automated IR test equipment. This paper looks at the general capabilities of the IRWindowsTM system, and then examines the specific results from its application in the PalmIR and Automotive IR production environments.

  7. An automated image processing method for classification of diabetic retinopathy stages from conjunctival microvasculature images

    Science.gov (United States)

    Khansari, Maziyar M.; O'Neill, William; Penn, Richard; Blair, Norman P.; Chau, Felix; Shahidi, Mahnaz

    2017-03-01

    The conjunctiva is a densely vascularized tissue of the eye that provides an opportunity for imaging of human microcirculation. In the current study, automated fine structure analysis of conjunctival microvasculature images was performed to discriminate stages of diabetic retinopathy (DR). The study population consisted of one group of nondiabetic control subjects (NC) and 3 groups of diabetic subjects, with no clinical DR (NDR), non-proliferative DR (NPDR), or proliferative DR (PDR). Ordinary least square regression and Fisher linear discriminant analyses were performed to automatically discriminate images between group pairs of subjects. Human observers who were masked to the grouping of subjects performed image discrimination between group pairs. Over 80% and 70% of images of subjects with clinical and non-clinical DR were correctly discriminated by the automated method, respectively. The discrimination rates of the automated method were higher than human observers. The fine structure analysis of conjunctival microvasculature images provided discrimination of DR stages and can be potentially useful for DR screening and monitoring.

  8. The BoneXpert method for automated determination of skeletal maturity

    DEFF Research Database (Denmark)

    Thodberg, Hans Henrik; Kreiborg, Sven; Juul, Anders

    2009-01-01

    Bone age rating is associated with a considerable variability from the human interpretation, and this is the motivation for presenting a new method for automated determination of bone age (skeletal maturity). The method, called BoneXpert, reconstructs, from radiographs of the hand, the borders...... component analysis; 3) the consensus bone age concept that defines bone age of each bone as the best estimate of the bone age of the other bones in the hand; 4) a common bone age model for males and females; and 5) the unified modelling of TW and GP bone age. BoneXpert is developed on 1559 images...

  9. A new automated assessment method for contrast–detail images by applying support vector machine and its robustness to nonlinear image processing

    International Nuclear Information System (INIS)

    Takei, Takaaki; Ikeda, Mitsuru; Imai, Kumiharu; Yamauchi-Kawaura, Chiyo; Kato, Katsuhiko; Isoda, Haruo

    2013-01-01

    The automated contrast–detail (C–D) analysis methods developed so-far cannot be expected to work well on images processed with nonlinear methods, such as noise reduction methods. Therefore, we have devised a new automated C–D analysis method by applying support vector machine (SVM), and tested for its robustness to nonlinear image processing. We acquired the CDRAD (a commercially available C–D test object) images at a tube voltage of 120 kV and a milliampere-second product (mAs) of 0.5–5.0. A partial diffusion equation based technique was used as noise reduction method. Three radiologists and three university students participated in the observer performance study. The training data for our SVM method was the classification data scored by the one radiologist for the CDRAD images acquired at 1.6 and 3.2 mAs and their noise-reduced images. We also compared the performance of our SVM method with the CDRAD Analyser algorithm. The mean C–D diagrams (that is a plot of the mean of the smallest visible hole diameter vs. hole depth) obtained from our devised SVM method agreed well with the ones averaged across the six human observers for both original and noise-reduced CDRAD images, whereas the mean C–D diagrams from the CDRAD Analyser algorithm disagreed with the ones from the human observers for both original and noise-reduced CDRAD images. In conclusion, our proposed SVM method for C–D analysis will work well for the images processed with the non-linear noise reduction method as well as for the original radiographic images.

  10. Screening of subfertile men for testicular carcinoma in situ by an automated image analysis-based cytological test of the ejaculate

    DEFF Research Database (Denmark)

    Almstrup, K; Lippert, Marianne; Mogensen, Hanne O

    2011-01-01

    a slightly lower sensitivity (0.51), possibly because of obstruction. We conclude that this novel non-invasive test combining automated immunocytochemistry and advanced image analysis allows identification of TC at the CIS stage with a high specificity, but a negative test does not completely exclude CIS...... and detected in ejaculates with specific CIS markers. We have built a high throughput framework involving automated immunocytochemical staining, scanning microscopy and in silico image analysis allowing automated detection and grading of CIS-like stained objects in semen samples. In this study, 1175 ejaculates...... from 765 subfertile men were tested using this framework. In 5/765 (0.65%) cases, CIS-like cells were identified in the ejaculate. Three of these had bilateral testicular biopsies performed and CIS was histologically confirmed in two. In total, 63 bilateral testicular biopsy were performed...

  11. TH-AB-207A-05: A Fully-Automated Pipeline for Generating CT Images Across a Range of Doses and Reconstruction Methods

    International Nuclear Information System (INIS)

    Young, S; Lo, P; Hoffman, J; Wahi-Anwar, M; Brown, M; McNitt-Gray, M; Noo, F

    2016-01-01

    Purpose: To evaluate the robustness of CAD or Quantitative Imaging methods, they should be tested on a variety of cases and under a variety of image acquisition and reconstruction conditions that represent the heterogeneity encountered in clinical practice. The purpose of this work was to develop a fully-automated pipeline for generating CT images that represent a wide range of dose and reconstruction conditions. Methods: The pipeline consists of three main modules: reduced-dose simulation, image reconstruction, and quantitative analysis. The first two modules of the pipeline can be operated in a completely automated fashion, using configuration files and running the modules in a batch queue. The input to the pipeline is raw projection CT data; this data is used to simulate different levels of dose reduction using a previously-published algorithm. Filtered-backprojection reconstructions are then performed using FreeCT_wFBP, a freely-available reconstruction software for helical CT. We also added support for an in-house, model-based iterative reconstruction algorithm using iterative coordinate-descent optimization, which may be run in tandem with the more conventional recon methods. The reduced-dose simulations and image reconstructions are controlled automatically by a single script, and they can be run in parallel on our research cluster. The pipeline was tested on phantom and lung screening datasets from a clinical scanner (Definition AS, Siemens Healthcare). Results: The images generated from our test datasets appeared to represent a realistic range of acquisition and reconstruction conditions that we would expect to find clinically. The time to generate images was approximately 30 minutes per dose/reconstruction combination on a hybrid CPU/GPU architecture. Conclusion: The automated research pipeline promises to be a useful tool for either training or evaluating performance of quantitative imaging software such as classifiers and CAD algorithms across the range

  12. TH-AB-207A-05: A Fully-Automated Pipeline for Generating CT Images Across a Range of Doses and Reconstruction Methods

    Energy Technology Data Exchange (ETDEWEB)

    Young, S; Lo, P; Hoffman, J; Wahi-Anwar, M; Brown, M; McNitt-Gray, M [UCLA School of Medicine, Los Angeles, CA (United States); Noo, F [University of Utah, Salt Lake City, UT (United States)

    2016-06-15

    Purpose: To evaluate the robustness of CAD or Quantitative Imaging methods, they should be tested on a variety of cases and under a variety of image acquisition and reconstruction conditions that represent the heterogeneity encountered in clinical practice. The purpose of this work was to develop a fully-automated pipeline for generating CT images that represent a wide range of dose and reconstruction conditions. Methods: The pipeline consists of three main modules: reduced-dose simulation, image reconstruction, and quantitative analysis. The first two modules of the pipeline can be operated in a completely automated fashion, using configuration files and running the modules in a batch queue. The input to the pipeline is raw projection CT data; this data is used to simulate different levels of dose reduction using a previously-published algorithm. Filtered-backprojection reconstructions are then performed using FreeCT-wFBP, a freely-available reconstruction software for helical CT. We also added support for an in-house, model-based iterative reconstruction algorithm using iterative coordinate-descent optimization, which may be run in tandem with the more conventional recon methods. The reduced-dose simulations and image reconstructions are controlled automatically by a single script, and they can be run in parallel on our research cluster. The pipeline was tested on phantom and lung screening datasets from a clinical scanner (Definition AS, Siemens Healthcare). Results: The images generated from our test datasets appeared to represent a realistic range of acquisition and reconstruction conditions that we would expect to find clinically. The time to generate images was approximately 30 minutes per dose/reconstruction combination on a hybrid CPU/GPU architecture. Conclusion: The automated research pipeline promises to be a useful tool for either training or evaluating performance of quantitative imaging software such as classifiers and CAD algorithms across the range

  13. Development of an automated asbestos counting software based on fluorescence microscopy.

    Science.gov (United States)

    Alexandrov, Maxym; Ichida, Etsuko; Nishimura, Tomoki; Aoki, Kousuke; Ishida, Takenori; Hirota, Ryuichi; Ikeda, Takeshi; Kawasaki, Tetsuo; Kuroda, Akio

    2015-01-01

    An emerging alternative to the commonly used analytical methods for asbestos analysis is fluorescence microscopy (FM), which relies on highly specific asbestos-binding probes to distinguish asbestos from interfering non-asbestos fibers. However, all types of microscopic asbestos analysis require laborious examination of large number of fields of view and are prone to subjective errors and large variability between asbestos counts by different analysts and laboratories. A possible solution to these problems is automated counting of asbestos fibers by image analysis software, which would lower the cost and increase the reliability of asbestos testing. This study seeks to develop a fiber recognition and counting software for FM-based asbestos analysis. We discuss the main features of the developed software and the results of its testing. Software testing showed good correlation between automated and manual counts for the samples with medium and high fiber concentrations. At low fiber concentrations, the automated counts were less accurate, leading us to implement correction mode for automated counts. While the full automation of asbestos analysis would require further improvements in accuracy of fiber identification, the developed software could already assist professional asbestos analysts and record detailed fiber dimensions for the use in epidemiological research.

  14. Evaluation of an antibody avidity index method for detecting recent human immunodeficiency virus type 1 infection using an automated chemiluminescence immunoassay.

    Science.gov (United States)

    Fernández, Gema; Manzardo, Christian; Montoliu, Alexandra; Campbell, Colin; Fernández, Gregorio; Casabona, Jordi; Miró, José Maria; Matas, Lurdes; Rivaya, Belén; González, Victoria

    2015-04-01

    Recent infection testing algorithms (RITAs) are used in public health surveillance to estimate the incidence of recently acquired HIV-1 infection. Our aims were (i) to evaluate the precision of the VITROS® Anti-HIV 1+2 automated antibody avidity assay for qualitative detection of antibodies to HIV 1+2 virus; (ii) to validate the accuracy of an automated guanidine-based antibody avidity assay to discriminate between recent and long standing infections using the VITROS 3600 platform; (iii) to compare this method with BED-CEIA assay; and (iv) to evaluate the occurrence of false recent misclassifications by the VITROS antibody avidity assay in patients with a CD4 count de Enfermedades Infecciosas y Microbiología Clínica. All rights reserved.

  15. Automated 13CO2 analyzing system for the 13C breath test

    International Nuclear Information System (INIS)

    Suehiro, Makiko; Kuroda, Akira; Maeda, Masahiro; Hinaga, Kou; Watanabe, Hiroyuki.

    1987-01-01

    An automated 13 CO 2 analyzing system for the 13 C breath test was designed, built and evaluated. The system, which was designed to be controlled by a micro-computer, includes CO 2 purification, 13 CO 2 abundance measurement, data processing and data filing. This article gives the description of the whole system with flow charts. This system has proved to work well and it has become feasible to dispose of 5 to 6 CO 2 samples per hour. With such a system, the 13 C breath test will be carried out much more easily and will obtain much greater popularity. (author)

  16. Experience of automation failures in training: effects on trust, automation bias, complacency and performance.

    Science.gov (United States)

    Sauer, Juergen; Chavaillaz, Alain; Wastell, David

    2016-06-01

    This work examined the effects of operators' exposure to various types of automation failures in training. Forty-five participants were trained for 3.5 h on a simulated process control environment. During training, participants either experienced a fully reliable, automatic fault repair facility (i.e. faults detected and correctly diagnosed), a misdiagnosis-prone one (i.e. faults detected but not correctly diagnosed) or a miss-prone one (i.e. faults not detected). One week after training, participants were tested for 3 h, experiencing two types of automation failures (misdiagnosis, miss). The results showed that automation bias was very high when operators trained on miss-prone automation encountered a failure of the diagnostic system. Operator errors resulting from automation bias were much higher when automation misdiagnosed a fault than when it missed one. Differences in trust levels that were instilled by the different training experiences disappeared during the testing session. Practitioner Summary: The experience of automation failures during training has some consequences. A greater potential for operator errors may be expected when an automatic system failed to diagnose a fault than when it failed to detect one.

  17. Path-Wise Test Data Generation Based on Heuristic Look-Ahead Methods

    Directory of Open Access Journals (Sweden)

    Ying Xing

    2014-01-01

    Full Text Available Path-wise test data generation is generally considered an important problem in the automation of software testing. In essence, it is a constraint optimization problem, which is often solved by search methods such as backtracking algorithms. In this paper, the backtracking algorithm branch and bound and state space search in artificial intelligence are introduced to tackle the problem of path-wise test data generation. The former is utilized to explore the space of potential solutions and the latter is adopted to construct the search tree dynamically. Heuristics are employed in the look-ahead stage of the search. Dynamic variable ordering is presented with a heuristic rule to break ties, values of a variable are determined by the monotonicity analysis on branching conditions, and maintaining path consistency is achieved through analysis on the result of interval arithmetic. An optimization method is also proposed to reduce the search space. The results of empirical experiments show that the search is conducted in a basically backtrack-free manner, which ensures both test data generation with promising performance and its excellence over some currently existing static and dynamic methods in terms of coverage. The results also demonstrate that the proposed method is applicable in engineering.

  18. Automated Detection of Salt Marsh Platforms : a Topographic Method

    Science.gov (United States)

    Goodwin, G.; Mudd, S. M.; Clubb, F. J.

    2017-12-01

    Monitoring the topographic evolution of coastal marshes is a crucial step toward improving the management of these valuable landscapes under the pressure of relative sea level rise and anthropogenic modification. However, determining their geometrically complex boundaries currently relies on spectral vegetation detection methods or requires labour-intensive field surveys and digitisation.We propose a novel method to reproducibly isolate saltmarsh scarps and platforms from a DEM. Field observations and numerical models show that saltmarshes mature into sub-horizontal platforms delineated by sub-vertical scarps: based on this premise, we identify scarps as lines of local maxima on a slope*relief raster, then fill landmasses from the scarps upward, thus isolating mature marsh platforms. Non-dimensional search parameters allow batch-processing of data without recalibration. We test our method using lidar-derived DEMs of six saltmarshes in England with varying tidal ranges and geometries, for which topographic platforms were manually isolated from tidal flats. Agreement between manual and automatic segregation exceeds 90% for resolutions of 1m, with all but one sites maintaining this performance for resolutions up to 3.5m. For resolutions of 1m, automatically detected platforms are comparable in surface area and elevation distribution to digitised platforms. We also find that our method allows the accurate detection of local bloc failures 3 times larger than the DEM resolution.Detailed inspection reveals that although tidal creeks were digitised as part of the marsh platform, automatic detection classifies them as part of the tidal flat, causing an increase in false negatives and overall platform perimeter. This suggests our method would benefit from a combination with existing creek detection algorithms. Fallen blocs and pioneer zones are inconsistently identified, particularly in macro-tidal marshes, leading to differences between digitisation and the automated method

  19. Automation-aided Task Loads Index based on the Automation Rate Reflecting the Effects on Human Operators in NPPs

    International Nuclear Information System (INIS)

    Lee, Seungmin; Seong, Poonghyun; Kim, Jonghyun

    2013-01-01

    Many researchers have found that a high automation rate does not guarantee high performance. Therefore, to reflect the effects of automation on human performance, a new estimation method of the automation rate that considers the effects of automation on human operators in nuclear power plants (NPPs) was suggested. These suggested measures express how much automation support human operators but it cannot express the change of human operators' workload, whether the human operators' workload is increased or decreased. Before considering automation rates, whether the adopted automation is good or bad might be estimated in advance. In this study, to estimate the appropriateness of automation according to the change of the human operators' task loads, automation-aided task loads index is suggested based on the concept of the suggested automation rate. To insure plant safety and efficiency on behalf of human operators, various automation systems have been installed in NPPs, and many works which were previously conducted by human operators can now be supported by computer-based operator aids. According to the characteristics of the automation types, the estimation method of the system automation and the cognitive automation rate were suggested. The proposed estimation method concentrates on the effects of introducing automation, so it directly express how much the automated system support human operators. Based on the suggested automation rates, the way to estimate how much the automated system can affect the human operators' cognitive task load is suggested in this study. When there is no automation, the calculated index is 1, and it means there is no change of human operators' task load

  20. Sleep-spindle detection: crowdsourcing and evaluating performance of experts, non-experts and automated methods

    DEFF Research Database (Denmark)

    Warby, Simon C.; Wendt, Sabrina Lyngbye; Welinder, Peter

    2014-01-01

    to crowdsource spindle identification by human experts and non-experts, and we compared their performance with that of automated detection algorithms in data from middle- to older-aged subjects from the general population. We also refined methods for forming group consensus and evaluating the performance...... of event detectors in physiological data such as electroencephalographic recordings from polysomnography. Compared to the expert group consensus gold standard, the highest performance was by individual experts and the non-expert group consensus, followed by automated spindle detectors. This analysis showed...... that crowdsourcing the scoring of sleep data is an efficient method to collect large data sets, even for difficult tasks such as spindle identification. Further refinements to spindle detection algorithms are needed for middle- to older-aged subjects....

  1. A fully-automated computer-assisted method of CT brain scan analysis for the measurement of cerebrospinal fluid spaces and brain absorption density

    International Nuclear Information System (INIS)

    Baldy, R.E.; Brindley, G.S.; Jacobson, R.R.; Reveley, M.A.; Lishman, W.A.; Ewusi-Mensah, I.; Turner, S.W.

    1986-01-01

    Computer-assisted methods of CT brain scan analysis offer considerable advantages over visual inspection, particularly in research; and several semi-automated methods are currently available. A new computer-assisted program is presented which provides fully automated processing of CT brain scans, depending on ''anatomical knowledge'' of where cerebrospinal fluid (CSF)-containing spaces are likely to lie. After identifying these regions of interest quantitative estimates are then provided of CSF content in each slice in cisterns, ventricles, Sylvian fissure and interhemispheric fissure. Separate measures are also provided of mean brain density in each slice. These estimates can be summated to provide total ventricular and total brain volumes. The program shows a high correlation with measures derived from mechanical planimetry and visual grading procedures, also when tested against a phantom brain of known ventricular volume. The advantages and limitations of the present program are discussed. (orig.)

  2. Digitising of ultrasonic pulse echo devices as a means for automation of ultrasonic testing

    International Nuclear Information System (INIS)

    Rosenberg, R.

    1989-01-01

    A universal multi-purpose test equipment - EPOCH 2002 - with a 12.5 cm picture tube and a digitally generated echo pulse representation with a format of 80x57 mm is introduced. The content of the screen and the equipment adjustment data can be passed on to external units via a video or RS 232 interface. These parameters favour the use of equipment in part-automated test systems, such as, for example, level monitoring with difficult geometries, continuous testing of shrinkage during profile extrusion and testing for cracks around bolts and rivets with a rotor scanner in aircraft construction. (orig./MM) [de

  3. Development and testing of the data automation subsystem for the Mariner Mars 1971 spacecraft

    Science.gov (United States)

    1971-01-01

    The data automation subsystem designed and built as part of the Mariner Mars 1971 program, sequences and controls the science instruments and formats all science data. A description of the subsystem with emphasis on major changes relative to Mariner Mars 1969 is presented. In addition, the complete test phase is described.

  4. An automated retinal imaging method for the early diagnosis of diabetic retinopathy.

    Science.gov (United States)

    Franklin, S Wilfred; Rajan, S Edward

    2013-01-01

    Diabetic retinopathy is a microvascular complication of long-term diabetes and is the major cause for eyesight loss due to changes in blood vessels of the retina. Major vision loss due to diabetic retinopathy is highly preventable with regular screening and timely intervention at the earlier stages. Retinal blood vessel segmentation methods help to identify the successive stages of such sight threatening diseases like diabetes. To develop and test a novel retinal imaging method which segments the blood vessels automatically from retinal images, which helps the ophthalmologists in the diagnosis and follow-up of diabetic retinopathy. This method segments each image pixel as vessel or nonvessel, which in turn, used for automatic recognition of the vasculature in retinal images. Retinal blood vessels were identified by means of a multilayer perceptron neural network, for which the inputs were derived from the Gabor and moment invariants-based features. Back propagation algorithm, which provides an efficient technique to change the weights in a feed forward network, is utilized in our method. Quantitative results of sensitivity, specificity and predictive values were obtained in our method and the measured accuracy of our segmentation algorithm was 95.3%, which is better than that presented by state-of-the-art approaches. The evaluation procedure used and the demonstrated effectiveness of our automated retinal imaging method proves itself as the most powerful tool to diagnose diabetic retinopathy in the earlier stages.

  5. Automated lesion detection on MRI scans using combined unsupervised and supervised methods

    International Nuclear Information System (INIS)

    Guo, Dazhou; Fridriksson, Julius; Fillmore, Paul; Rorden, Christopher; Yu, Hongkai; Zheng, Kang; Wang, Song

    2015-01-01

    Accurate and precise detection of brain lesions on MR images (MRI) is paramount for accurately relating lesion location to impaired behavior. In this paper, we present a novel method to automatically detect brain lesions from a T1-weighted 3D MRI. The proposed method combines the advantages of both unsupervised and supervised methods. First, unsupervised methods perform a unified segmentation normalization to warp images from the native space into a standard space and to generate probability maps for different tissue types, e.g., gray matter, white matter and fluid. This allows us to construct an initial lesion probability map by comparing the normalized MRI to healthy control subjects. Then, we perform non-rigid and reversible atlas-based registration to refine the probability maps of gray matter, white matter, external CSF, ventricle, and lesions. These probability maps are combined with the normalized MRI to construct three types of features, with which we use supervised methods to train three support vector machine (SVM) classifiers for a combined classifier. Finally, the combined classifier is used to accomplish lesion detection. We tested this method using T1-weighted MRIs from 60 in-house stroke patients. Using leave-one-out cross validation, the proposed method can achieve an average Dice coefficient of 73.1 % when compared to lesion maps hand-delineated by trained neurologists. Furthermore, we tested the proposed method on the T1-weighted MRIs in the MICCAI BRATS 2012 dataset. The proposed method can achieve an average Dice coefficient of 66.5 % in comparison to the expert annotated tumor maps provided in MICCAI BRATS 2012 dataset. In addition, on these two test datasets, the proposed method shows competitive performance to three state-of-the-art methods, including Stamatakis et al., Seghier et al., and Sanjuan et al. In this paper, we introduced a novel automated procedure for lesion detection from T1-weighted MRIs by combining both an unsupervised and a

  6. Automated processing of endoscopic surgical instruments.

    Science.gov (United States)

    Roth, K; Sieber, J P; Schrimm, H; Heeg, P; Buess, G

    1994-10-01

    This paper deals with the requirements for automated processing of endoscopic surgical instruments. After a brief analysis of the current problems, solutions are discussed. Test-procedures have been developed to validate the automated processing, so that the cleaning results are guaranteed and reproducable. Also a device for testing and cleaning was designed together with Netzsch Newamatic and PCI, called TC-MIC, to automate processing and reduce manual work.

  7. Automated Extraction of Formalin-Fixed, Paraffin-Embedded Tissue for High-Risk Human Papillomavirus Testing of Head and Neck Squamous Cell Carcinomas Using the Roche Cobas 4800 System.

    Science.gov (United States)

    Kerr, Darcy A; Sweeney, Brenda; Arpin, Ronald N; Ring, Melissa; Pitman, Martha B; Wilbur, David C; Faquin, William C

    2016-08-01

    -Testing for high-risk human papillomavirus (HR-HPV) in head and neck squamous cell carcinomas (HNSCCs) is important for both prognostication and clinical management. Several testing platforms are available for HR-HPV; however, effective alternative automated approaches are needed. -To assess the performance of the automated Roche cobas 4800 HPV real-time polymerase chain reaction-based system on formalin-fixed, paraffin-embedded HNSCC specimens and compare results with standard methods of in situ hybridization (ISH) and p16 immunohistochemistry. -Formalin-fixed, paraffin-embedded samples of HNSCC were collected from archival specimens in the Department of Pathology, Massachusetts General Hospital (Boston), and prepared using the automated system by deparaffinization and dehydration followed by tissue lysis. Samples were integrated into routine cervical cytology testing runs by cobas. Corresponding formalin-fixed, paraffin-embedded samples were evaluated for HR-HPV by ISH and p16 by immunohistochemistry. Discrepant cases were adjudicated by polymerase chain reaction. -Sixty-two HNSCC samples were analyzed using the automated cobas system, ISH, and immunohistochemistry. Fifty-two percent (n = 32 of 62) of formalin-fixed, paraffin-embedded tumors were positive for HR-HPV by cobas. Eighty-eight percent (n = 28 of 32) of cases were the HPV 16 subtype and 12% (n = 4 of 32) were other HR-HPV subtypes. Corresponding testing with ISH was concordant in 92% (n = 57 of 62) of cases. Compared with the adjudication polymerase chain reaction standard, there were 3 false-positive cases by cobas. -Concordance in HNSCC HR-HPV status between cobas and ISH was more than 90%. The cobas demonstrated a sensitivity of 100% and a specificity of 91% for detection of HR-HPV. Advantages favoring cobas include its automation, cost efficiency, objective results, and ease of performance.

  8. Automation of radioimmunoassay

    International Nuclear Information System (INIS)

    Yamaguchi, Chisato; Yamada, Hideo; Iio, Masahiro

    1974-01-01

    Automation systems for measuring Australian antigen by radioimmunoassay under development were discussed. Samples were processed as follows: blood serum being dispensed by automated sampler to the test tube, and then incubated under controlled time and temperature; first counting being omitted; labelled antibody being dispensed to the serum after washing; samples being incubated and then centrifuged; radioactivities in the precipitate being counted by auto-well counter; measurements being tabulated by automated typewriter. Not only well-type counter but also position counter was studied. (Kanao, N.)

  9. A method for the automated detection phishing websites through both site characteristics and image analysis

    Science.gov (United States)

    White, Joshua S.; Matthews, Jeanna N.; Stacy, John L.

    2012-06-01

    Phishing website analysis is largely still a time-consuming manual process of discovering potential phishing sites, verifying if suspicious sites truly are malicious spoofs and if so, distributing their URLs to the appropriate blacklisting services. Attackers increasingly use sophisticated systems for bringing phishing sites up and down rapidly at new locations, making automated response essential. In this paper, we present a method for rapid, automated detection and analysis of phishing websites. Our method relies on near real-time gathering and analysis of URLs posted on social media sites. We fetch the pages pointed to by each URL and characterize each page with a set of easily computed values such as number of images and links. We also capture a screen-shot of the rendered page image, compute a hash of the image and use the Hamming distance between these image hashes as a form of visual comparison. We provide initial results demonstrate the feasibility of our techniques by comparing legitimate sites to known fraudulent versions from Phishtank.com, by actively introducing a series of minor changes to a phishing toolkit captured in a local honeypot and by performing some initial analysis on a set of over 2.8 million URLs posted to Twitter over a 4 days in August 2011. We discuss the issues encountered during our testing such as resolvability and legitimacy of URL's posted on Twitter, the data sets used, the characteristics of the phishing sites we discovered, and our plans for future work.

  10. Automation-aided Task Loads Index based on the Automation Rate Reflecting the Effects on Human Operators in NPPs

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Seungmin; Seong, Poonghyun [Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of); Kim, Jonghyun [KEPCO International Nuclear Graduate School, Ulsan (Korea, Republic of)

    2013-05-15

    Many researchers have found that a high automation rate does not guarantee high performance. Therefore, to reflect the effects of automation on human performance, a new estimation method of the automation rate that considers the effects of automation on human operators in nuclear power plants (NPPs) was suggested. These suggested measures express how much automation support human operators but it cannot express the change of human operators' workload, whether the human operators' workload is increased or decreased. Before considering automation rates, whether the adopted automation is good or bad might be estimated in advance. In this study, to estimate the appropriateness of automation according to the change of the human operators' task loads, automation-aided task loads index is suggested based on the concept of the suggested automation rate. To insure plant safety and efficiency on behalf of human operators, various automation systems have been installed in NPPs, and many works which were previously conducted by human operators can now be supported by computer-based operator aids. According to the characteristics of the automation types, the estimation method of the system automation and the cognitive automation rate were suggested. The proposed estimation method concentrates on the effects of introducing automation, so it directly express how much the automated system support human operators. Based on the suggested automation rates, the way to estimate how much the automated system can affect the human operators' cognitive task load is suggested in this study. When there is no automation, the calculated index is 1, and it means there is no change of human operators' task load.

  11. Contaminant analysis automation, an overview

    International Nuclear Information System (INIS)

    Hollen, R.; Ramos, O. Jr.

    1996-01-01

    To meet the environmental restoration and waste minimization goals of government and industry, several government laboratories, universities, and private companies have formed the Contaminant Analysis Automation (CAA) team. The goal of this consortium is to design and fabricate robotics systems that standardize and automate the hardware and software of the most common environmental chemical methods. In essence, the CAA team takes conventional, regulatory- approved (EPA Methods) chemical analysis processes and automates them. The automation consists of standard laboratory modules (SLMs) that perform the work in a much more efficient, accurate, and cost- effective manner

  12. Automated interpretation of PET/CT images in patients with lung cancer

    DEFF Research Database (Denmark)

    Gutte, Henrik; Jakobsson, David; Olofsson, Fredrik

    2007-01-01

    cancer. METHODS: A total of 87 patients who underwent PET/CT examinations due to suspected lung cancer comprised the training group. The test group consisted of PET/CT images from 49 patients suspected with lung cancer. The consensus interpretations by two experienced physicians were used as the 'gold...... method measured as the area under the receiver operating characteristic curve, was 0.97 in the test group, with an accuracy of 92%. The sensitivity was 86% at a specificity of 100%. CONCLUSIONS: A completely automated method using artificial neural networks can be used to detect lung cancer......PURPOSE: To develop a completely automated method based on image processing techniques and artificial neural networks for the interpretation of combined [(18)F]fluorodeoxyglucose (FDG) positron emission tomography (PET) and computed tomography (CT) images for the diagnosis and staging of lung...

  13. Method of Modeling Questions for Automated Grading of Students’ Responses in E-Learning Systems

    Directory of Open Access Journals (Sweden)

    A. A. Gurchenkov

    2015-01-01

    scoring of algorithmic questions. The module supports both standalone mode using the test pages, and the mode of integration with any LMS. Special attention is given to fault tolerance of the module by allowing a continuous state preservation of algorithmic questions in the database. The developed module architecture enables the integration of any types of input and scoring algorithms in LMS. An advantage of the suggested approach is the capability to generate a number of question options, which is necessary to form the homework or tests to be given to groups of students.Application. The results can be used to extend the functionality of e-learning systems for the inclusion of complex question types that support automated scoring of student answers.Further studies. Further research based on this method may include the integration of new student’s answer input methods and their scoring algorithms, as well as creating other algorithms for the system feedback loop implemented in answer ( function. For example, one of the urgent problems consists in generation of hints based on the analysis of students’ wrong responses.

  14. An optimized method for automated analysis of algal pigments by HPLC

    NARCIS (Netherlands)

    van Leeuwe, M. A.; Villerius, L. A.; Roggeveld, J.; Visser, R. J. W.; Stefels, J.

    2006-01-01

    A recent development in algal pigment analysis by high-performance liquid chromatography (HPLC) is the application of automation. An optimization of a complete sampling and analysis protocol applied specifically in automation has not yet been performed. In this paper we show that automation can only

  15. Performance of five research-domain automated WM lesion segmentation methods in a multi-center MS study

    DEFF Research Database (Denmark)

    de Sitter, Alexandra; Steenwijk, Martijn D; Ruet, Aurélie

    2017-01-01

    (Lesion-TOADS); and k-Nearest Neighbor with Tissue Type Priors (kNN-TTP). Main software parameters were optimized using a training set (N = 18), and formal testing was performed on the remaining patients (N = 52). To evaluate volumetric agreement with the reference segmentations, intraclass correlation......BACKGROUND AND PURPOSE: In vivoidentification of white matter lesions plays a key-role in evaluation of patients with multiple sclerosis (MS). Automated lesion segmentation methods have been developed to substitute manual outlining, but evidence of their performance in multi-center investigations......-one-center-out design to exclude the center of interest from the training phase to evaluate the performance of the method on 'unseen' center. RESULTS: Compared to the reference mean lesion volume (4.85 ± 7.29 mL), the methods displayed a mean difference of 1.60 ± 4.83 (Cascade), 2.31 ± 7.66 (LGA), 0.44 ± 4.68 (LPA), 1...

  16. Tried and tested automation system helps to reduce air pollution. Ausgereifte Automatisierung hilft beim Reduzieren schaedlicher Emissionen

    Energy Technology Data Exchange (ETDEWEB)

    Haack, R. (Still Otto GmbH, Bochum (Germany, F.R.)); Schreiter, K.D. (Siemens AG, Erlangen (Germany, F.R.). Bereich Anlagentechnik)

    An important step in the coking process is the cooling of the red hot coke. This is mainly done by dowsing with water. The result is the emission of pollutant gases and the waste of heat energy. Disadvantages of this kind can be reduced by the use of a coke drying and cooling plant. This requires, however, because of its complex technology, a tried and tested automation system. A homogeneous solution to the problems faced by the automation system is found in the SIMATIC S5-150U automation unit which was delivered with the coke drying and cooling plant for Pohang (Korea) from the firm Still Otto GmbH in Bochum. This is the largest of its kind. (orig.).

  17. An Automated Baseline Correction Method Based on Iterative Morphological Operations.

    Science.gov (United States)

    Chen, Yunliang; Dai, Liankui

    2018-05-01

    Raman spectra usually suffer from baseline drift caused by fluorescence or other reasons. Therefore, baseline correction is a necessary and crucial step that must be performed before subsequent processing and analysis of Raman spectra. An automated baseline correction method based on iterative morphological operations is proposed in this work. The method can adaptively determine the structuring element first and then gradually remove the spectral peaks during iteration to get an estimated baseline. Experiments on simulated data and real-world Raman data show that the proposed method is accurate, fast, and flexible for handling different kinds of baselines in various practical situations. The comparison of the proposed method with some state-of-the-art baseline correction methods demonstrates its advantages over the existing methods in terms of accuracy, adaptability, and flexibility. Although only Raman spectra are investigated in this paper, the proposed method is hopefully to be used for the baseline correction of other analytical instrumental signals, such as IR spectra and chromatograms.

  18. Automated exchange transfusion and exchange rate.

    Science.gov (United States)

    Funato, M; Shimada, S; Tamai, H; Taki, H; Yoshioka, Y

    1989-10-01

    An automated blood exchange transfusion (BET) with a two-site technique has been devised by Goldmann et al and by us, using an infusion pump. With this method, we successfully performed exchange transfusions 189 times in the past four years on 110 infants with birth weights ranging from 530 g to 4,000 g. The exchange rate by the automated method was compared with the rate by Diamond's method. Serum bilirubin (SB) levels before and after BET and the maximal SB rebound within 24 hours after BET were: 21.6 +/- 2.4, 11.5 +/- 2.2, and 15.0 +/- 1.5 mg/dl in the automated method, and 22.0 +/- 2.9, 11.2 +/- 2.5, and 17.7 +/- 3.2 mg/dl in Diamond's method, respectively. The result showed that the maximal rebound of the SB level within 24 hours after BET was significantly lower in the automated method than in Diamond's method (p less than 0.01), though SB levels before and after BET were not significantly different between the two methods. The exchange rate was also measured by means of staining the fetal red cells (F cells) both in the automated method and in Diamond's method, and comparing them. The exchange rate of F cells in Diamond's method went down along the theoretical exchange curve proposed by Diamond, while the rate in the automated method was significantly better than in Diamond's, especially in the early stage of BET (p less than 0.01). We believe that the use of this automated method may give better results than Diamond's method in the rate of exchange, because this method is performed with a two-site technique using a peripheral artery and vein.

  19. Bayesian ISOLA: new tool for automated centroid moment tensor inversion

    Science.gov (United States)

    Vackář, Jiří; Burjánek, Jan; Gallovič, František; Zahradník, Jiří; Clinton, John

    2017-04-01

    Focal mechanisms are important for understanding seismotectonics of a region, and they serve as a basic input for seismic hazard assessment. Usually, the point source approximation and the moment tensor (MT) are used. We have developed a new, fully automated tool for the centroid moment tensor (CMT) inversion in a Bayesian framework. It includes automated data retrieval, data selection where station components with various instrumental disturbances and high signal-to-noise are rejected, and full-waveform inversion in a space-time grid around a provided hypocenter. The method is innovative in the following aspects: (i) The CMT inversion is fully automated, no user interaction is required, although the details of the process can be visually inspected latter on many figures which are automatically plotted.(ii) The automated process includes detection of disturbances based on MouseTrap code, so disturbed recordings do not affect inversion.(iii) A data covariance matrix calculated from pre-event noise yields an automated weighting of the station recordings according to their noise levels and also serves as an automated frequency filter suppressing noisy frequencies.(iv) Bayesian approach is used, so not only the best solution is obtained, but also the posterior probability density function.(v) A space-time grid search effectively combined with the least-squares inversion of moment tensor components speeds up the inversion and allows to obtain more accurate results compared to stochastic methods. The method has been tested on synthetic and observed data. It has been tested by comparison with manually processed moment tensors of all events greater than M≥3 in the Swiss catalogue over 16 years using data available at the Swiss data center (http://arclink.ethz.ch). The quality of the results of the presented automated process is comparable with careful manual processing of data. The software package programmed in Python has been designed to be as versatile as possible in

  20. Integrated Markov-neural reliability computation method: A case for multiple automated guided vehicle system

    International Nuclear Information System (INIS)

    Fazlollahtabar, Hamed; Saidi-Mehrabad, Mohammad; Balakrishnan, Jaydeep

    2015-01-01

    This paper proposes an integrated Markovian and back propagation neural network approaches to compute reliability of a system. While states of failure occurrences are significant elements for accurate reliability computation, Markovian based reliability assessment method is designed. Due to drawbacks shown by Markovian model for steady state reliability computations and neural network for initial training pattern, integration being called Markov-neural is developed and evaluated. To show efficiency of the proposed approach comparative analyses are performed. Also, for managerial implication purpose an application case for multiple automated guided vehicles (AGVs) in manufacturing networks is conducted. - Highlights: • Integrated Markovian and back propagation neural network approach to compute reliability. • Markovian based reliability assessment method. • Managerial implication is shown in an application case for multiple automated guided vehicles (AGVs) in manufacturing networks

  1. Automated Cable Preparation for Robotized Stator Cable Winding

    Directory of Open Access Journals (Sweden)

    Erik Hultman

    2017-04-01

    Full Text Available A method for robotized cable winding of the Uppsala University Wave Energy Converter generator stator has previously been presented and validated. The purpose of this study is to present and validate further developments to the method: automated stand-alone equipment for the preparation of the winding cables. The cable preparation consists of three parts: feeding the cable from a drum, forming the cable end and cutting the cable. Forming and cutting the cable was previously done manually and only small cable drums could be handled. Therefore the robot cell needed to be stopped frequently. The new equipment was tested in an experimental robot stator cable winding setup. Through the experiments, the equipment was validated to be able to perform fully automated and robust cable preparation. Suggestions are also given on how to further develop the equipment with regards to performance, robustness and quality. Hence, this work represents another important step towards demonstrating completely automated robotized stator cable winding.

  2. Use of Automated Scoring in Spoken Language Assessments for Test Takers with Speech Impairments. Research Report. ETS RR-17-42

    Science.gov (United States)

    Loukina, Anastassia; Buzick, Heather

    2017-01-01

    This study is an evaluation of the performance of automated speech scoring for speakers with documented or suspected speech impairments. Given that the use of automated scoring of open-ended spoken responses is relatively nascent and there is little research to date that includes test takers with disabilities, this small exploratory study focuses…

  3. Automated testing of microstrip detectors readout system for dual x-ray dual energy

    International Nuclear Information System (INIS)

    Bolanos, L.; Cabal, A. E.; Diaz, A.; Swientek, K.; Giubellino, P.; Marzari-Chiesa, A.; Prino, F.; Ramello, L.

    2008-01-01

    Circuits that carry out the signal acquisition and processing by multiple channels are required in digital radiography. These circuits should be tested in order to characterize their performance. This paper describes an automated system to control (by a software, from a personal computer) the characterization of a system based on RX64DTH specific integrated circuits with microstrip detectors. The results are shown. (Author)

  4. Methods for Automated and Continuous Commissioning of Building Systems

    Energy Technology Data Exchange (ETDEWEB)

    Larry Luskay; Michael Brambley; Srinivas Katipamula

    2003-04-30

    Avoidance of poorly installed HVAC systems is best accomplished at the close of construction by having a building and its systems put ''through their paces'' with a well conducted commissioning process. This research project focused on developing key components to enable the development of tools that will automatically detect and correct equipment operating problems, thus providing continuous and automatic commissioning of the HVAC systems throughout the life of a facility. A study of pervasive operating problems reveled the following would most benefit from an automated and continuous commissioning process: (1) faulty economizer operation; (2) malfunctioning sensors; (3) malfunctioning valves and dampers, and (4) access to project design data. Methodologies for detecting system operation faults in these areas were developed and validated in ''bare-bones'' forms within standard software such as spreadsheets, databases, statistical or mathematical packages. Demonstrations included flow diagrams and simplified mock-up applications. Techniques to manage data were demonstrated by illustrating how test forms could be populated with original design information and the recommended sequence of operation for equipment systems. Proposed tools would use measured data, design data, and equipment operating parameters to diagnosis system problems. Steps for future research are suggested to help more toward practical application of automated commissioning and its high potential to improve equipment availability, increase occupant comfort, and extend the life of system equipment.

  5. USING LEARNING VECTOR QUANTIZATION METHOD FOR AUTOMATED IDENTIFICATION OF MYCOBACTERIUM TUBERCULOSIS

    Directory of Open Access Journals (Sweden)

    Endah Purwanti

    2012-01-01

    Full Text Available In this paper, we are developing an automated method for the detection of tubercle bacilli in clinical specimens, principally the sputum. This investigation is the first attempt to automatically identify TB bacilli in sputum using image processing and learning vector quantization (LVQ techniques. The evaluation of the learning vector quantization (LVQ was carried out on Tuberculosis dataset show that average of accuracy is 91,33%.

  6. Time-Motion Analysis of Four Automated Systems for the Detection of Chlamydia trachomatis and Neisseria gonorrhoeae by Nucleic Acid Amplification Testing.

    Science.gov (United States)

    Williams, James A; Eddleman, Laura; Pantone, Amy; Martinez, Regina; Young, Stephen; Van Der Pol, Barbara

    2014-08-01

    Next-generation diagnostics for Chlamydia trachomatis and Neisseria gonorrhoeae are available on semi- or fully-automated platforms. These systems require less hands-on time than older platforms and are user friendly. Four automated systems, the ABBOTT m2000 system, Becton Dickinson Viper System with XTR Technology, Gen-Probe Tigris DTS system, and Roche cobas 4800 system, were evaluated for total run time, hands-on time, and walk-away time. All of the systems evaluated in this time-motion study were able to complete a diagnostic test run within an 8-h work shift, instrument setup and operation were straightforward and uncomplicated, and walk-away time ranged from approximately 90 to 270 min in a head-to-head comparison of each system. All of the automated systems provide technical staff with increased time to perform other tasks during the run, offer easy expansion of the diagnostic test menu, and have the ability to increase specimen throughput. © 2013 Society for Laboratory Automation and Screening.

  7. Automated processing of fluorescence in-situ hybridization slides for HER2 testing in breast and gastro-esophageal carcinomas.

    Science.gov (United States)

    Tafe, Laura J; Allen, Samantha F; Steinmetz, Heather B; Dokus, Betty A; Cook, Leanne J; Marotti, Jonathan D; Tsongalis, Gregory J

    2014-08-01

    HER2 fluorescence in-situ hybridization (FISH) is used in breast and gastro-esophageal carcinoma for determining HER2 gene amplification and patients' eligibility for HER2 targeted therapeutics. Traditional manual processing of the FISH slides is labor intensive because of multiple steps that require hands on manipulation of the slides and specifically timed intervals between steps. This highly manual processing also introduces inter-run and inter-operator variability that may affect the quality of the FISH result. Therefore, we sought to incorporate an automated processing instrument into our FISH workflow. Twenty-six cases including breast (20) and gastro-esophageal (6) cancer comprising 23 biopsies and three excision specimens were tested for HER2 FISH (Pathvysion, Abbott) using the Thermobrite Elite (TBE) system (Leica). Up to 12 slides can be run simultaneously. All cases were previously tested by the Pathvysion HER2 FISH assay with manual preparation. Twenty cells were counted by two observers for each case; five cases were tested on three separate runs by different operators to evaluate the precision and inter-operator variability. There was 100% concordance in the scoring between the manual and TBE methods as well as among the five cases that were tested on three runs. Only one case failed due to poor probe hybridization. In total, seven cases were positive for HER2 amplification (HER2:CEP17 ratio >2.2) and the remaining 19 were negative (HER2:CEP17 ratio <1.8) utilizing the 2007 ASCO/CAP scoring criteria. Due to the automated denaturation and hybridization, for each run, there was a reduction in labor of 3.5h which could then be dedicated to other lab functions. The TBE is a walk away pre- and post-hybridization system that automates FISH slide processing, improves work flow and consistency and saves approximately 3.5h of technologist time. The instrument has a small footprint thus occupying minimal counter space. TBE processed slides performed

  8. The Harvard Automated Phone Task: new performance-based activities of daily living tests for early Alzheimer's disease.

    Science.gov (United States)

    Marshall, Gad A; Dekhtyar, Maria; Bruno, Jonathan M; Jethwani, Kamal; Amariglio, Rebecca E; Johnson, Keith A; Sperling, Reisa A; Rentz, Dorene M

    2015-12-01

    Impairment in activities of daily living is a major burden for Alzheimer's disease dementia patients and caregivers. Multiple subjective scales and a few performance-based instruments have been validated and proven to be reliable in measuring instrumental activities of daily living in Alzheimer's disease dementia but less so in amnestic mild cognitive impairment and preclinical Alzheimer's disease. To validate the Harvard Automated Phone Task, a new performance-based activities of daily living test for early Alzheimer's disease, which assesses high level tasks that challenge seniors in daily life. In a cross-sectional study, the Harvard Automated Phone Task was associated with demographics and cognitive measures through univariate and multivariate analyses; ability to discriminate across diagnostic groups was assessed; test-retest reliability with the same and alternate versions was assessed in a subset of participants; and the relationship with regional cortical thickness was assessed in a subset of participants. Academic clinical research center. One hundred and eighty two participants were recruited from the community (127 clinically normal elderly and 45 young normal participants) and memory disorders clinics at Brigham and Women's Hospital and Massachusetts General Hospital (10 participants with mild cognitive impairment). As part of the Harvard Automated Phone Task, participants navigated an interactive voice response system to refill a prescription (APT-Script), select a new primary care physician (APT-PCP), and make a bank account transfer and payment (APT-Bank). The 3 tasks were scored based on time, errors, and repetitions from which composite z-scores were derived, as well as a separate report of correct completion of the task. We found that the Harvard Automated Phone Task discriminated well between diagnostic groups (APT-Script: p=0.002; APT-PCP: pHarvard Automated Phone Task and executive function (APT-PCP: pHarvard Automated Phone Task, which

  9. Volumetric analysis of pelvic hematomas after blunt trauma using semi-automated seeded region growing segmentation: a method validation study.

    Science.gov (United States)

    Dreizin, David; Bodanapally, Uttam K; Neerchal, Nagaraj; Tirada, Nikki; Patlas, Michael; Herskovits, Edward

    2016-11-01

    Manually segmented traumatic pelvic hematoma volumes are strongly predictive of active bleeding at conventional angiography, but the method is time intensive, limiting its clinical applicability. We compared volumetric analysis using semi-automated region growing segmentation to manual segmentation and diameter-based size estimates in patients with pelvic hematomas after blunt pelvic trauma. A 14-patient cohort was selected in an anonymous randomized fashion from a dataset of patients with pelvic binders at MDCT, collected retrospectively as part of a HIPAA-compliant IRB-approved study from January 2008 to December 2013. To evaluate intermethod differences, one reader (R1) performed three volume measurements using the manual technique and three volume measurements using the semi-automated technique. To evaluate interobserver differences for semi-automated segmentation, a second reader (R2) performed three semi-automated measurements. One-way analysis of variance was used to compare differences in mean volumes. Time effort was also compared. Correlation between the two methods as well as two shorthand appraisals (greatest diameter, and the ABC/2 method for estimating ellipsoid volumes) was assessed with Spearman's rho (r). Intraobserver variability was lower for semi-automated compared to manual segmentation, with standard deviations ranging between ±5-32 mL and ±17-84 mL, respectively (p = 0.0003). There was no significant difference in mean volumes between the two readers' semi-automated measurements (p = 0.83); however, means were lower for the semi-automated compared with the manual technique (manual: mean and SD 309.6 ± 139 mL; R1 semi-auto: 229.6 ± 88.2 mL, p = 0.004; R2 semi-auto: 243.79 ± 99.7 mL, p = 0.021). Despite differences in means, the correlation between the two methods was very strong and highly significant (r = 0.91, p hematoma volumes correlate strongly with manually segmented volumes. Since semi-automated segmentation

  10. Quantitative traits for the tail suspension test: automation, optimization, and BXD RI mapping.

    Science.gov (United States)

    Lad, Heena V; Liu, Lin; Payá-Cano, José L; Fernandes, Cathy; Schalkwyk, Leonard C

    2007-07-01

    Immobility in the tail suspension test (TST) is considered a model of despair in a stressful situation, and acute treatment with antidepressants reduces immobility. Inbred strains of mouse exhibit widely differing baseline levels of immobility in the TST and several quantitative trait loci (QTLs) have been nominated. The labor of manual scoring and various scoring criteria make obtaining robust data and comparisons across different laboratories problematic. Several studies have validated strain gauge and video analysis methods by comparison with manual scoring. We set out to find objective criteria for automated scoring parameters that maximize the biological information obtained, using a video tracking system on tapes of tail suspension tests of 24 lines of the BXD recombinant inbred panel and the progenitor strains C57BL/6J and DBA/2J. The maximum genetic effect size is captured using the highest time resolution and a low mobility threshold. Dissecting the trait further by comparing genetic association of multiple measures reveals good evidence for loci involved in immobility on chromosomes 4 and 15. These are best seen when using a high threshold for immobility, despite the overall better heritability at the lower threshold. A second trial of the test has greater duration of immobility and a completely different genetic profile. Frequency of mobility is also an independent phenotype, with a distal chromosome 1 locus.

  11. A Fully Automated Method to Detect and Segment a Manufactured Object in an Underwater Color Image

    Science.gov (United States)

    Barat, Christian; Phlypo, Ronald

    2010-12-01

    We propose a fully automated active contours-based method for the detection and the segmentation of a moored manufactured object in an underwater image. Detection of objects in underwater images is difficult due to the variable lighting conditions and shadows on the object. The proposed technique is based on the information contained in the color maps and uses the visual attention method, combined with a statistical approach for the detection and an active contour for the segmentation of the object to overcome the above problems. In the classical active contour method the region descriptor is fixed and the convergence of the method depends on the initialization. With our approach, this dependence is overcome with an initialization using the visual attention results and a criterion to select the best region descriptor. This approach improves the convergence and the processing time while providing the advantages of a fully automated method.

  12. Determination of the Optimized Automation Rate considering Effects of Automation on Human Operators in Nuclear Power Plants

    International Nuclear Information System (INIS)

    Lee, Seung Min; Seong, Poong Hyun; Kim, Jong Hyun; Kim, Man Cheol

    2015-01-01

    Automation refers to the use of a device or a system to perform a function previously performed by a human operator. It is introduced to reduce the human errors and to enhance the performance in various industrial fields, including the nuclear industry. However, these positive effects are not always achieved in complex systems such as nuclear power plants (NPPs). An excessive introduction of automation can generate new roles for human operators and change activities in unexpected ways. As more automation systems are accepted, the ability of human operators to detect automation failures and resume manual control is diminished. This disadvantage of automation is called the Out-of-the- Loop (OOTL) problem. We should consider the positive and negative effects of automation at the same time to determine the appropriate level of the introduction of automation. Thus, in this paper, we suggest an estimation method to consider the positive and negative effects of automation at the same time to determine the appropriate introduction of automation. This concept is limited in that it does not consider the effects of automation on human operators. Thus, a new estimation method for automation rate was suggested to overcome this problem

  13. Automated Fast Screening Method for Cocaine Identification in Seized Drug Samples Using a Portable Fourier Transform Infrared (FT-IR) Instrument.

    Science.gov (United States)

    Mainali, Dipak; Seelenbinder, John

    2016-05-01

    Quick and presumptive identification of seized drug samples without destroying evidence is necessary for law enforcement officials to control the trafficking and abuse of drugs. This work reports an automated screening method to detect the presence of cocaine in seized samples using portable Fourier transform infrared (FT-IR) spectrometers. The method is based on the identification of well-defined characteristic vibrational frequencies related to the functional group of the cocaine molecule and is fully automated through the use of an expert system. Traditionally, analysts look for key functional group bands in the infrared spectra and characterization of the molecules present is dependent on user interpretation. This implies the need for user expertise, especially in samples that likely are mixtures. As such, this approach is biased and also not suitable for non-experts. The method proposed in this work uses the well-established "center of gravity" peak picking mathematical algorithm and combines it with the conditional reporting feature in MicroLab software to provide an automated method that can be successfully employed by users with varied experience levels. The method reports the confidence level of cocaine present only when a certain number of cocaine related peaks are identified by the automated method. Unlike library search and chemometric methods that are dependent on the library database or the training set samples used to build the calibration model, the proposed method is relatively independent of adulterants and diluents present in the seized mixture. This automated method in combination with a portable FT-IR spectrometer provides law enforcement officials, criminal investigators, or forensic experts a quick field-based prescreening capability for the presence of cocaine in seized drug samples. © The Author(s) 2016.

  14. Total laboratory automation: Do stat tests still matter?

    Science.gov (United States)

    Dolci, Alberto; Giavarina, Davide; Pasqualetti, Sara; Szőke, Dominika; Panteghini, Mauro

    2017-07-01

    During the past decades the healthcare systems have rapidly changed and today hospital care is primarily advocated for critical patients and acute treatments, for which laboratory test results are crucial and need to be always reported in predictably short turnaround time (TAT). Laboratories in the hospital setting can face this challenge by changing their organization from a compartmentalized laboratory department toward a decision making-based laboratory department. This requires the implementation of a core laboratory, that exploits total laboratory automation (TLA) using technological innovation in analytical platforms, track systems and information technology, including middleware, and a number of satellite specialized laboratory sections cooperating with care teams for specific medical conditions. In this laboratory department model, the short TAT for all first-line tests performed by TLA in the core laboratory represents the key paradigm, where no more stat testing is required because all samples are handled in real-time and (auto)validated results dispatched in a time that fulfills clinical needs. To optimally reach this goal, laboratories should be actively involved in managing all the steps covering the total examination process, speeding up also extra-laboratory phases, such sample delivery. Furthermore, to warrant effectiveness and not only efficiency, all the processes, e.g. specimen integrity check, should be managed by middleware through a predefined set of rules defined in light of the clinical governance. Crown Copyright © 2017. Published by Elsevier Inc. All rights reserved.

  15. Automated model building

    CERN Document Server

    Caferra, Ricardo; Peltier, Nicholas

    2004-01-01

    This is the first book on automated model building, a discipline of automated deduction that is of growing importance Although models and their construction are important per se, automated model building has appeared as a natural enrichment of automated deduction, especially in the attempt to capture the human way of reasoning The book provides an historical overview of the field of automated deduction, and presents the foundations of different existing approaches to model construction, in particular those developed by the authors Finite and infinite model building techniques are presented The main emphasis is on calculi-based methods, and relevant practical results are provided The book is of interest to researchers and graduate students in computer science, computational logic and artificial intelligence It can also be used as a textbook in advanced undergraduate courses

  16. Automated collimation testing by determining the statistical correlation coefficient of Talbot self-images.

    Science.gov (United States)

    Rana, Santosh; Dhanotia, Jitendra; Bhatia, Vimal; Prakash, Shashi

    2018-04-01

    In this paper, we propose a simple, fast, and accurate technique for detection of collimation position of an optical beam using the self-imaging phenomenon and correlation analysis. Herrera-Fernandez et al. [J. Opt.18, 075608 (2016)JOOPDB0150-536X10.1088/2040-8978/18/7/075608] proposed an experimental arrangement for collimation testing by comparing the period of two different self-images produced by a single diffraction grating. Following their approach, we propose a testing procedure based on correlation coefficient (CC) for efficient detection of variation in the size and fringe width of the Talbot self-images and thereby the collimation position. When the beam is collimated, the physical properties of the self-images of the grating, such as its size and fringe width, do not vary from one Talbot plane to the other and are identical; the CC is maximum in such a situation. For the de-collimated position, the size and fringe width of the self-images vary, and correspondingly the CC decreases. Hence, the magnitude of CC is a measure of degree of collimation. Using the method, we could set the collimation position to a resolution of 1 μm, which relates to ±0.25   μ    radians in terms of collimation angle (for testing a collimating lens of diameter 46 mm and focal length 300 mm). In contrast to most collimation techniques reported to date, the proposed technique does not require a translation/rotation of the grating, use of complicated phase evaluation algorithms, or an intricate method for determination of period of the grating or its self-images. The technique is fully automated and provides high resolution and precision.

  17. A new automated NaCl based robust method for routine production of gallium-68 labeled peptides

    International Nuclear Information System (INIS)

    Schultz, Michael K.; Mueller, Dirk; Baum, Richard P.; Leonard Watkins, G.; Breeman, Wouter A.P.

    2013-01-01

    A new NaCl based method for preparation of gallium-68 labeled radiopharmaceuticals has been adapted for use with an automated gallium-68 generator system. The method was evaluated based on 56 preparations of [ 68 Ga]DOTATOC and compared to a similar acetone-based approach. Advantages of the new NaCl approach include reduced preparation time ( 97%), and specific activity (>40 MBq nmole −1 [ 68 Ga]DOTATOC) and is well-suited for clinical production of radiopharmaceuticals. - Highlights: ► A NaCl based automated production of Ga-68-radiopharmaceuticals is described. ► Using 5 M NaCl for pre-purification of 68Ga eliminates the need for organic solvents. ► The method provides for high efficiency, specific activity, and radiochemical purity. ► The new method eliminates the need for the quality control by gas chromatography

  18. Microbleed detection using automated segmentation (MIDAS): a new method applicable to standard clinical MR images.

    Science.gov (United States)

    Seghier, Mohamed L; Kolanko, Magdalena A; Leff, Alexander P; Jäger, Hans R; Gregoire, Simone M; Werring, David J

    2011-03-23

    Cerebral microbleeds, visible on gradient-recalled echo (GRE) T2* MRI, have generated increasing interest as an imaging marker of small vessel diseases, with relevance for intracerebral bleeding risk or brain dysfunction. Manual rating methods have limited reliability and are time-consuming. We developed a new method for microbleed detection using automated segmentation (MIDAS) and compared it with a validated visual rating system. In thirty consecutive stroke service patients, standard GRE T2* images were acquired and manually rated for microbleeds by a trained observer. After spatially normalizing each patient's GRE T2* images into a standard stereotaxic space, the automated microbleed detection algorithm (MIDAS) identified cerebral microbleeds by explicitly incorporating an "extra" tissue class for abnormal voxels within a unified segmentation-normalization model. The agreement between manual and automated methods was assessed using the intraclass correlation coefficient (ICC) and Kappa statistic. We found that MIDAS had generally moderate to good agreement with the manual reference method for the presence of lobar microbleeds (Kappa = 0.43, improved to 0.65 after manual exclusion of obvious artefacts). Agreement for the number of microbleeds was very good for lobar regions: (ICC = 0.71, improved to ICC = 0.87). MIDAS successfully detected all patients with multiple (≥2) lobar microbleeds. MIDAS can identify microbleeds on standard MR datasets, and with an additional rapid editing step shows good agreement with a validated visual rating system. MIDAS may be useful in screening for multiple lobar microbleeds.

  19. Automated Critical PeakPricing Field Tests: 2006 Pilot ProgramDescription and Results

    Energy Technology Data Exchange (ETDEWEB)

    Piette, Mary Ann; Watson, David; Motegi, Naoya; Kiliccote, Sila

    2007-06-19

    During 2006 Lawrence Berkeley National Laboratory (LBNL) and the Demand Response Research Center (DRRC) performed a technology evaluation for the Pacific Gas and Electric Company (PG&E) Emerging Technologies Programs. This report summarizes the design, deployment, and results from the 2006 Automated Critical Peak Pricing Program (Auto-CPP). The program was designed to evaluate the feasibility of deploying automation systems that allow customers to participate in critical peak pricing (CPP) with a fully-automated response. The 2006 program was in operation during the entire six-month CPP period from May through October. The methodology for this field study included site recruitment, control strategy development, automation system deployment, and evaluation of sites' participation in actual CPP events through the summer of 2006. LBNL recruited sites in PG&E's territory in northern California through contacts from PG&E account managers, conferences, and industry meetings. Each site contact signed a memorandum of understanding with LBNL that outlined the activities needed to participate in the Auto-CPP program. Each facility worked with LBNL to select and implement control strategies for demand response and developed automation system designs based on existing Internet connectivity and building control systems. Once the automation systems were installed, LBNL conducted communications tests to ensure that the Demand Response Automation Server (DRAS) correctly provided and logged the continuous communications of the CPP signals with the energy management and control system (EMCS) for each site. LBNL also observed and evaluated Demand Response (DR) shed strategies to ensure proper commissioning of controls. The communication system allowed sites to receive day-ahead as well as day-of signals for pre-cooling, a DR strategy used at a few sites. Measurement of demand response was conducted using two different baseline models for estimating peak load savings. One

  20. GSMA: Gene Set Matrix Analysis, An Automated Method for Rapid Hypothesis Testing of Gene Expression Data

    Directory of Open Access Journals (Sweden)

    Chris Cheadle

    2007-01-01

    Full Text Available Background: Microarray technology has become highly valuable for identifying complex global changes in gene expression patterns. The assignment of functional information to these complex patterns remains a challenging task in effectively interpreting data and correlating results from across experiments, projects and laboratories. Methods which allow the rapid and robust evaluation of multiple functional hypotheses increase the power of individual researchers to data mine gene expression data more efficiently.Results: We have developed (gene set matrix analysis GSMA as a useful method for the rapid testing of group-wise up- or downregulation of gene expression simultaneously for multiple lists of genes (gene sets against entire distributions of gene expression changes (datasets for single or multiple experiments. The utility of GSMA lies in its flexibility to rapidly poll gene sets related by known biological function or as designated solely by the end-user against large numbers of datasets simultaneously.Conclusions: GSMA provides a simple and straightforward method for hypothesis testing in which genes are tested by groups across multiple datasets for patterns of expression enrichment.

  1. [Comparison of manual and automated (MagNA Pure) nucleic acid isolation methods in molecular diagnosis of HIV infections].

    Science.gov (United States)

    Alp, Alpaslan; Us, Dürdal; Hasçelik, Gülşen

    2004-01-01

    Rapid quantitative molecular methods are very important for the diagnosis of human immunodeficiency virus (HIV) infections, assessment of prognosis and follow up. The purpose of this study was to compare and evaluate the performances of conventional manual extraction method and automated MagNA Pure system, for the nucleic acid isolation step which is the first and most important step in molecular diagnosis of HIV infections. Plasma samples of 35 patients in which anti-HIV antibodies were found as positive by microparticule enzyme immunoassay and confirmed by immunoblotting method, were included in the study. The nucleic acids obtained simultaneously by manual isolation kit (Cobas Amplicor, HIV-1 Monitor Test, version 1.5, Roche Diagnostics) and automated system (MagNA Pure LC Total Nucleic Acid Isolation Kit, Roche Diagnostics), were amplified and detected in Cobas Amplicor (Roche Diagnostics) instrument. Twenty three of 35 samples (65.7%) were found to be positive, and 9 (25.7%) were negative by both of the methods. The agreement between the methods were detected as 91.4%, for qualitative results. Viral RNA copies detected by manual and MagNA Pure isolation methods were found between 76.0-7.590.000 (mean: 487.143) and 113.0-20.300.0000 (mean: 2.174.097) copies/ml, respectively. When both of the overall and individual results were evaluated, the number of RNA copies obtained with automatized system, were found higher than the manual method (p<0.05). Three samples which had low numbers of nucleic acids (113, 773, 857, respectively) with MagNA Pure, yielded negative results with manual method. In conclusion, the automatized MagNA Pure system was found to be a reliable, rapid and practical method for the isolation of HIV-RNA.

  2. Comparison of semi-automated center-dot and fully automated endothelial cell analyses from specular microscopy images.

    Science.gov (United States)

    Maruoka, Sachiko; Nakakura, Shunsuke; Matsuo, Naoko; Yoshitomi, Kayo; Katakami, Chikako; Tabuchi, Hitoshi; Chikama, Taiichiro; Kiuchi, Yoshiaki

    2017-10-30

    To evaluate two specular microscopy analysis methods across different endothelial cell densities (ECDs). Endothelial images of one eye from each of 45 patients were taken by using three different specular microscopes (three replicates each). To determine the consistency of the center-dot method, we compared SP-6000 and SP-2000P images. CME-530 and SP-6000 images were compared to assess the consistency of the fully automated method. The SP-6000 images from the two methods were compared. Intraclass correlation coefficients (ICCs) for the three measurements were calculated, and parametric multiple comparisons tests and Bland-Altman analysis were performed. The ECD mean value was 2425 ± 883 (range 516-3707) cells/mm 2 . ICC values were > 0.9 for all three microscopes for ECD, but the coefficients of variation (CVs) were 0.3-0.6. For ECD measurements, Bland-Altman analysis revealed that the mean difference was 42 cells/mm 2 between the SP-2000P and SP-6000 for the center-dot method; 57 cells/mm 2 between the SP-6000 measurements from both methods; and -5 cells/mm 2 between the SP-6000 and CME-530 for the fully automated method (95% limits of agreement: - 201 to 284 cell/mm 2 , - 410 to 522 cells/mm 2 , and - 327 to 318 cells/mm 2 , respectively). For CV measurements, the mean differences were - 3, - 12, and 13% (95% limits of agreement - 18 to 11, - 26 to 2, and - 5 to 32%, respectively). Despite using three replicate measurements, the precision of the center-dot method with the SP-2000P and SP-6000 software was only ± 10% for ECD data and was even worse for the fully automated method. Japan Clinical Trials Register ( http://www.umin.ac.jp/ctr/index/htm9 ) number UMIN 000015236.

  3. Automated Groundwater Screening

    International Nuclear Information System (INIS)

    Taylor, Glenn A.; Collard, Leonard B.

    2005-01-01

    The Automated Intruder Analysis has been extended to include an Automated Ground Water Screening option. This option screens 825 radionuclides while rigorously applying the National Council on Radiation Protection (NCRP) methodology. An extension to that methodology is presented to give a more realistic screening factor for those radionuclides which have significant daughters. The extension has the promise of reducing the number of radionuclides which must be tracked by the customer. By combining the Automated Intruder Analysis with the Automated Groundwater Screening a consistent set of assumptions and databases is used. A method is proposed to eliminate trigger values by performing rigorous calculation of the screening factor thereby reducing the number of radionuclides sent to further analysis. Using the same problem definitions as in previous groundwater screenings, the automated groundwater screening found one additional nuclide, Ge-68, which failed the screening. It also found that 18 of the 57 radionuclides contained in NCRP Table 3.1 failed the screening. This report describes the automated groundwater screening computer application

  4. Automation of the linear array HPV genotyping test and its application for routine typing of human papillomaviruses in cervical specimens of women without cytological abnormalities in Switzerland.

    Science.gov (United States)

    Dobec, Marinko; Bannwart, Fridolin; Kaeppeli, Franz; Cassinotti, Pascal

    2009-05-01

    There is a need for reliable, automated high throughput HPV detection and genotyping methods for pre- and post-prophylactic vaccine intervention analyses. To optimize the linear array (LA) HPV genotyping test (Roche Diagnostics, Rotkreuz) in regard to possible automation steps for the routine laboratory diagnosis of HPV infections and to analyze the HPV genotype distribution in cervical specimens of women without cytological abnormalities in Switzerland. 680 cervical cell specimens with normal cytology, obtained from women undergoing routine cervical screening by liquid-based Pap smear, were analyzed by the LA HPV genotyping test for HPV-DNA. The automation of the LA HPV genotyping test resulted in a total hands-on time reduction of 255 min (from 480 to 225 min; 53%). Any of 37 HPV genotypes were detected in 117 (17.2%) and high-risk (HR) HPV in 55 (8.1%) of 680 women with normal cytology. The highest prevalence of any HPV (28.1%) and HR-HPV (15.1%) was observed in age-group 21-30 and showed a continuous decrease in older age-groups. The most common HR-HPV genotypes were HPV-16 (12%), HPV-31 (9.4%), HPV-52 (6%), HPV-51 (5.1%), HPV-45 (4.3%), HPV-58 (4.3%) and HPV-59 (4.3%). The optimization and automation of the LA HPV genotyping test makes it suited for high throughput HPV detection and typing. The epidemiological data provides information about distribution of HPV genotypes in women without cytological abnormalities in Switzerland and may be important for determining the future impact of vaccines and potential changes in the country's epidemiological HPV profile.

  5. Transformation From a Conventional Clinical Microbiology Laboratory to Full Automation.

    Science.gov (United States)

    Moreno-Camacho, José L; Calva-Espinosa, Diana Y; Leal-Leyva, Yoseli Y; Elizalde-Olivas, Dolores C; Campos-Romero, Abraham; Alcántar-Fernández, Jonathan

    2017-12-22

    To validate the performance, reproducibility, and reliability of BD automated instruments in order to establish a fully automated clinical microbiology laboratory. We used control strains and clinical samples to assess the accuracy, reproducibility, and reliability of the BD Kiestra WCA, the BD Phoenix, and BD Bruker MALDI-Biotyper instruments and compared them to previously established conventional methods. The following processes were evaluated: sample inoculation and spreading, colony counts, sorting of cultures, antibiotic susceptibility test, and microbial identification. The BD Kiestra recovered single colonies in less time than conventional methods (e.g. E. coli, 7h vs 10h, respectively) and agreement between both methodologies was excellent for colony counts (κ=0.824) and sorting cultures (κ=0.821). Antibiotic susceptibility tests performed with BD Phoenix and disk diffusion demonstrated 96.3% agreement with both methods. Finally, we compared microbial identification in BD Phoenix and Bruker MALDI-Biotyper and observed perfect agreement (κ=1) and identification at a species level for control strains. Together these instruments allow us to process clinical urine samples in 36h (effective time). The BD automated technologies have improved performance compared with conventional methods, and are suitable for its implementation in very busy microbiology laboratories. © American Society for Clinical Pathology 2017. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  6. Automated reconstruction of pre-transformation microstructures in zirconium

    International Nuclear Information System (INIS)

    Krishna, K.V. Mani; Tripathi, P.; Hiwarkar, V.D.; Pant, P.; Samajdar, I.; Srivastava, D.; Dey, G.K.

    2010-01-01

    An automated reconstruction of the pre-transformation microstructure from the microtexture data of the post-transformation product phase is proposed. The method involves identifying triplets of neighboring product grains with a common variant and linking such neighboring triplets via a generalized misorientation criterion. The approach is non-iterative and extremely efficient computationally. The method was tested successfully for different post-transformation microstructures in zirconium.

  7. Comparison of Particulate Mercury Measured with Manual and Automated Methods

    Directory of Open Access Journals (Sweden)

    Rachel Russo

    2011-01-01

    Full Text Available A study was conducted to compare measuring particulate mercury (HgP with the manual filter method and the automated Tekran system. Simultaneous measurements were conducted with the Tekran and Teflon filter methodologies in the marine and coastal continental atmospheres. Overall, the filter HgP values were on the average 21% higher than the Tekran HgP, and >85% of the data were outside of ±25% region surrounding the 1:1 line. In some cases the filter values were as much as 3-fold greater, with

  8. Routine tests and automated urinalysis in patients with suspected urinary tract infection at the ED

    NARCIS (Netherlands)

    Middelkoop, S. J. M.; van Pelt, L. J.; Kampinga, G. A.; ter Maaten, J. C.; Stegeman, C. A.

    Background: Urinary tract infections (UTIs) are frequently encountered. Diagnostics of UTI (urine dipstick, Gram stain, urine culture) lack proven accuracy and precision in the emergency department. Utility of automated urinalysis shows promise for UTI diagnosis but has not been validated. Methods:

  9. Studying human-automation interactions: methodological lessons learned from the human-centred automation experiments 1997-2001

    International Nuclear Information System (INIS)

    Massaiu, Salvatore; Skjerve, Ann Britt Miberg; Skraaning, Gyrd Jr.; Strand, Stine; Waeroe, Irene

    2004-04-01

    This report documents the methodological lessons learned from the Human Centred Automation (HCA) programme both in terms of psychometric evaluation of the measurement techniques developed for human-automation interaction study, and in terms of the application of advanced statistical methods for analysis of experiments. The psychometric evaluation is based on data from the four experiments performed within the HCA programme. The result is a single-source reference text of measurement instruments for the study of human-automation interaction, part of which were specifically developed by the programme. The application of advanced statistical techniques is exemplified by additional analyses performed on the IPSN-HCA experiment of 1998. Special importance is given to the statistical technique Structural Equation Modeling, for the possibility it offers to advance, and empirically test, comprehensive explanations about human-automation interactions. The additional analyses of the IPSN-HCA experiment investigated how the operators formed judgments about their own performance. The issue is of substantive interest for human automation interaction research because the operators' over- or underestimation of their own performance could be seen as a symptom of human-machine mismatch, and a potential latent failure. These analyses concluded that it is the interplay between (1) the level of automation and several factors that determines the operators' bias in performance self-estimation: (2) the nature of the task, (3) the level of scenario complexity, and (4) the level of trust in the automatic system. A structural model that expresses the interplay of all these factors was empirically evaluated and was found able to provide a concise and elegant explanation of the intricate pattern of relationships between the identified factors. (Author)

  10. Hybrid digital signal processing and neural networks for automated diagnostics using NDE methods

    International Nuclear Information System (INIS)

    Upadhyaya, B.R.; Yan, W.

    1993-11-01

    The primary purpose of the current research was to develop an integrated approach by combining information compression methods and artificial neural networks for the monitoring of plant components using nondestructive examination data. Specifically, data from eddy current inspection of heat exchanger tubing were utilized to evaluate this technology. The focus of the research was to develop and test various data compression methods (for eddy current data) and the performance of different neural network paradigms for defect classification and defect parameter estimation. Feedforward, fully-connected neural networks, that use the back-propagation algorithm for network training, were implemented for defect classification and defect parameter estimation using a modular network architecture. A large eddy current tube inspection database was acquired from the Metals and Ceramics Division of ORNL. These data were used to study the performance of artificial neural networks for defect type classification and for estimating defect parameters. A PC-based data preprocessing and display program was also developed as part of an expert system for data management and decision making. The results of the analysis showed that for effective (low-error) defect classification and estimation of parameters, it is necessary to identify proper feature vectors using different data representation methods. The integration of data compression and artificial neural networks for information processing was established as an effective technique for automation of diagnostics using nondestructive examination methods

  11. Red Blood Cell Count Automation Using Microscopic Hyperspectral Imaging Technology.

    Science.gov (United States)

    Li, Qingli; Zhou, Mei; Liu, Hongying; Wang, Yiting; Guo, Fangmin

    2015-12-01

    Red blood cell counts have been proven to be one of the most frequently performed blood tests and are valuable for early diagnosis of some diseases. This paper describes an automated red blood cell counting method based on microscopic hyperspectral imaging technology. Unlike the light microscopy-based red blood count methods, a combined spatial and spectral algorithm is proposed to identify red blood cells by integrating active contour models and automated two-dimensional k-means with spectral angle mapper algorithm. Experimental results show that the proposed algorithm has better performance than spatial based algorithm because the new algorithm can jointly use the spatial and spectral information of blood cells.

  12. Automated audiometry using apple iOS-based application technology.

    Science.gov (United States)

    Foulad, Allen; Bui, Peggy; Djalilian, Hamid

    2013-11-01

    The aim of this study is to determine the feasibility of an Apple iOS-based automated hearing testing application and to compare its accuracy with conventional audiometry. Prospective diagnostic study. Setting Academic medical center. An iOS-based software application was developed to perform automated pure-tone hearing testing on the iPhone, iPod touch, and iPad. To assess for device variations and compatibility, preliminary work was performed to compare the standardized sound output (dB) of various Apple device and headset combinations. Forty-two subjects underwent automated iOS-based hearing testing in a sound booth, automated iOS-based hearing testing in a quiet room, and conventional manual audiometry. The maximum difference in sound intensity between various Apple device and headset combinations was 4 dB. On average, 96% (95% confidence interval [CI], 91%-100%) of the threshold values obtained using the automated test in a sound booth were within 10 dB of the corresponding threshold values obtained using conventional audiometry. When the automated test was performed in a quiet room, 94% (95% CI, 87%-100%) of the threshold values were within 10 dB of the threshold values obtained using conventional audiometry. Under standardized testing conditions, 90% of the subjects preferred iOS-based audiometry as opposed to conventional audiometry. Apple iOS-based devices provide a platform for automated air conduction audiometry without requiring extra equipment and yield hearing test results that approach those of conventional audiometry.

  13. Architecture and method for optimization of cloud resources used in software testing

    Directory of Open Access Journals (Sweden)

    Joana Coelho Vigário

    2016-03-01

    Full Text Available Nowadays systems can evolve quickly, and to this growth is associated, for example, the production of new features, or even the change of system perspective, required by the stakeholders. These conditions require the development of software testing in order to validate the systems. Run a large battery of tests sequentially can take hours. However, tests can run faster in a distributed environment with rapid availability of pre-configured systems, such as cloud computing. There is increasing demand for automation of the entire process, including integration, build, running tests and management of cloud resources.This paper aims to demonstrate the applicability of the practice continuous integration (CI in Information Systems, for automating the build and software testing performed in a distributed environment of cloud computing, in order to achieve optimization and elasticity of the resources provided by the cloud.

  14. Radiographic examination takes on an automated image

    International Nuclear Information System (INIS)

    Aman, J.

    1988-01-01

    Automation can be effectively applied to nondestructive testing (NDT). Until recently, film radiography used in NDT was largely a manual process, involving the shooting of a series of x-rays, manually positioned and manually processed. In other words, much radiographic work is being done the way it was over 50 years ago. Significant advances in automation have changed the face of manufacturing, and industry has shared in the benefits brought by such progress. The handling of parts, which was once responsible for a large measure of labor costs, is now assigned to robotic equipment. In nondestructive testing processes, some progress has been achieved in automation - for example, in real-time imaging systems. However, only recently have truly automated NDT begun to emerge. There are two major reasons to introduce automation into NDT - reliability and productivity. Any process or technique that can improve the reliability of parts testing could easily justify the capital investments required

  15. Automated extraction of DNA from biological stains on fabric from crime cases. A comparison of a manual and three automated methods.

    Science.gov (United States)

    Stangegaard, Michael; Hjort, Benjamin B; Hansen, Thomas N; Hoflund, Anders; Mogensen, Helle S; Hansen, Anders J; Morling, Niels

    2013-05-01

    The presence of PCR inhibitors in extracted DNA may interfere with the subsequent quantification and short tandem repeat (STR) reactions used in forensic genetic DNA typing. DNA extraction from fabric for forensic genetic purposes may be challenging due to the occasional presence of PCR inhibitors that may be co-extracted with the DNA. Using 120 forensic trace evidence samples consisting of various types of fabric, we compared three automated DNA extraction methods based on magnetic beads (PrepFiler Express Forensic DNA Extraction Kit on an AutoMate Express, QIAsyphony DNA Investigator kit either with the sample pre-treatment recommended by Qiagen or an in-house optimized sample pre-treatment on a QIAsymphony SP) and one manual method (Chelex) with the aim of reducing the amount of PCR inhibitors in the DNA extracts and increasing the proportion of reportable STR-profiles. A total of 480 samples were processed. The highest DNA recovery was obtained with the PrepFiler Express kit on an AutoMate Express while the lowest DNA recovery was obtained using a QIAsymphony SP with the sample pre-treatment recommended by Qiagen. Extraction using a QIAsymphony SP with the sample pre-treatment recommended by Qiagen resulted in the lowest percentage of PCR inhibition (0%) while extraction using manual Chelex resulted in the highest percentage of PCR inhibition (51%). The largest number of reportable STR-profiles was obtained with DNA from samples extracted with the PrepFiler Express kit (75%) while the lowest number was obtained with DNA from samples extracted using a QIAsymphony SP with the sample pre-treatment recommended by Qiagen (41%). Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  16. Testing Automation of Context-Oriented Programs Using Separation Logic

    Directory of Open Access Journals (Sweden)

    Mohamed A. El-Zawawy

    2014-01-01

    Full Text Available A new approach for programming that enables switching among contexts of commands during program execution is context-oriented programming (COP. This technique is more structured and modular than object-oriented and aspect-oriented programming and hence more flexible. For context-oriented programming, as implemented in COP languages such as ContextJ* and ContextL, this paper introduces accurate operational semantics. The language model of this paper uses Java concepts and is equipped with layer techniques for activation/deactivation of layer contexts. This paper also presents a logical system for COP programs. This logic is necessary for the automation of testing, developing, and validating of partial correctness specifications for COP programs and is an extension of separation logic. A mathematical soundness proof for the logical system against the proposed operational semantics is presented in the paper.

  17. The use of an automated flight test management system in the development of a rapid-prototyping flight research facility

    Science.gov (United States)

    Duke, Eugene L.; Hewett, Marle D.; Brumbaugh, Randal W.; Tartt, David M.; Antoniewicz, Robert F.; Agarwal, Arvind K.

    1988-01-01

    An automated flight test management system (ATMS) and its use to develop a rapid-prototyping flight research facility for artificial intelligence (AI) based flight systems concepts are described. The ATMS provides a flight test engineer with a set of tools that assist in flight planning and simulation. This system will be capable of controlling an aircraft during the flight test by performing closed-loop guidance functions, range management, and maneuver-quality monitoring. The rapid-prototyping flight research facility is being developed at the Dryden Flight Research Facility of the NASA Ames Research Center (Ames-Dryden) to provide early flight assessment of emerging AI technology. The facility is being developed as one element of the aircraft automation program which focuses on the qualification and validation of embedded real-time AI-based systems.

  18. Nondestructive testing method

    International Nuclear Information System (INIS)

    Porter, J.F.

    1996-01-01

    Nondestructive testing (NDT) is the use of physical and chemical methods for evaluating material integrity without impairing its intended usefulness or continuing service. Nondestructive tests are used by manufaturer's for the following reasons: 1) to ensure product reliability; 2) to prevent accidents and save human lives; 3) to aid in better product design; 4) to control manufacturing processes; and 5) to maintain a uniform quality level. Nondestructive testing is used extensively on power plants, oil and chemical refineries, offshore oil rigs and pipeline (NDT can even be conducted underwater), welds on tanks, boilers, pressure vessels and heat exchengers. NDT is now being used for testing concrete and composite materials. Because of the criticality of its application, NDT should be performed and the results evaluated by qualified personnel. There are five basic nondestructive examination methods: 1) liquid penetrant testing - method used for detecting surface flaws in materials. This method can be used for metallic and nonmetallic materials, portable and relatively inexpensive. 2) magnetic particle testing - method used to detect surface and subsurface flaws in ferromagnetic materials; 3) radiographic testing - method used to detect internal flaws and significant variation in material composition and thickness; 4) ultrasonic testing - method used to detect internal and external flaws in materials. This method uses ultrasonics to measure thickness of a material or to examine the internal structure for discontinuities. 5) eddy current testing - method used to detect surface and subsurface flaws in conductive materials. Not one nondestructive examination method can find all discontinuities in all of the materials capable of being tested. The most important consideration is for the specifier of the test to be familiar with the test method and its applicability to the type and geometry of the material and the flaws to be detected

  19. Association between fully automated MRI-based volumetry of different brain regions and neuropsychological test performance in patients with amnestic mild cognitive impairment and Alzheimer's disease.

    Science.gov (United States)

    Arlt, Sönke; Buchert, Ralph; Spies, Lothar; Eichenlaub, Martin; Lehmbeck, Jan T; Jahn, Holger

    2013-06-01

    Fully automated magnetic resonance imaging (MRI)-based volumetry may serve as biomarker for the diagnosis in patients with mild cognitive impairment (MCI) or dementia. We aimed at investigating the relation between fully automated MRI-based volumetric measures and neuropsychological test performance in amnestic MCI and patients with mild dementia due to Alzheimer's disease (AD) in a cross-sectional and longitudinal study. In order to assess a possible prognostic value of fully automated MRI-based volumetry for future cognitive performance, the rate of change of neuropsychological test performance over time was also tested for its correlation with fully automated MRI-based volumetry at baseline. In 50 subjects, 18 with amnestic MCI, 21 with mild AD, and 11 controls, neuropsychological testing and T1-weighted MRI were performed at baseline and at a mean follow-up interval of 2.1 ± 0.5 years (n = 19). Fully automated MRI volumetry of the grey matter volume (GMV) was performed using a combined stereotactic normalisation and segmentation approach as provided by SPM8 and a set of pre-defined binary lobe masks. Left and right hippocampus masks were derived from probabilistic cytoarchitectonic maps. Volumes of the inner and outer liquor space were also determined automatically from the MRI. Pearson's test was used for the correlation analyses. Left hippocampal GMV was significantly correlated with performance in memory tasks, and left temporal GMV was related to performance in language tasks. Bilateral frontal, parietal and occipital GMVs were correlated to performance in neuropsychological tests comprising multiple domains. Rate of GMV change in the left hippocampus was correlated with decline of performance in the Boston Naming Test (BNT), Mini-Mental Status Examination, and trail making test B (TMT-B). The decrease of BNT and TMT-A performance over time correlated with the loss of grey matter in multiple brain regions. We conclude that fully automated MRI

  20. LOGICAL CONDITIONS ANALYSIS METHOD FOR DIAGNOSTIC TEST RESULTS DECODING APPLIED TO COMPETENCE ELEMENTS PROFICIENCY

    Directory of Open Access Journals (Sweden)

    V. I. Freyman

    2015-11-01

    Full Text Available Subject of Research.Representation features of education results for competence-based educational programs are analyzed. Solution importance of decoding and proficiency estimation for elements and components of discipline parts of competences is shown. The purpose and objectives of research are formulated. Methods. The paper deals with methods of mathematical logic, Boolean algebra, and parametrical analysis of complex diagnostic test results, that controls proficiency of some discipline competence elements. Results. The method of logical conditions analysis is created. It will give the possibility to formulate logical conditions for proficiency determination of each discipline competence element, controlled by complex diagnostic test. Normalized test result is divided into noncrossing zones; a logical condition about controlled elements proficiency is formulated for each of them. Summarized characteristics for test result zones are imposed. An example of logical conditions forming for diagnostic test with preset features is provided. Practical Relevance. The proposed method of logical conditions analysis is applied in the decoding algorithm of proficiency test diagnosis for discipline competence elements. It will give the possibility to automate the search procedure for elements with insufficient proficiency, and is also usable for estimation of education results of a discipline or a component of competence-based educational program.

  1. The Harvard Automated Phone Task: new performance-based activities of daily living tests for early Alzheimer’s disease

    Science.gov (United States)

    Marshall, Gad A.; Dekhtyar, Maria; Bruno, Jonathan M.; Jethwani, Kamal; Amariglio, Rebecca E.; Johnson, Keith A.; Sperling, Reisa A.; Rentz, Dorene M.

    2015-01-01

    Background Impairment in activities of daily living is a major burden for Alzheimer’s disease dementia patients and caregivers. Multiple subjective scales and a few performance-based instruments have been validated and proven to be reliable in measuring instrumental activities of daily living in Alzheimer’s disease dementia but less so in amnestic mild cognitive impairment and preclinical Alzheimer’s disease. Objective To validate the Harvard Automated Phone Task, a new performance-based activities of daily living test for early Alzheimer’s disease, which assesses high level tasks that challenge seniors in daily life. Design In a cross-sectional study, the Harvard Automated Phone Task was associated with demographics and cognitive measures through univariate and multivariate analyses; ability to discriminate across diagnostic groups was assessed; test-retest reliability with the same and alternate versions was assessed in a subset of participants; and the relationship with regional cortical thickness was assessed in a subset of participants. Setting Academic clinical research center. Participants One hundred and eighty two participants were recruited from the community (127 clinically normal elderly and 45 young normal participants) and memory disorders clinics at Brigham and Women’s Hospital and Massachusetts General Hospital (10 participants with mild cognitive impairment). Measurements As part of the Harvard Automated Phone Task, participants navigated an interactive voice response system to refill a prescription (APT-Script), select a new primary care physician (APT-PCP), and make a bank account transfer and payment (APT-Bank). The 3 tasks were scored based on time, errors, and repetitions from which composite z-scores were derived, as well as a separate report of correct completion of the task. Results We found that the Harvard Automated Phone Task discriminated well between diagnostic groups (APT-Script: p=0.002; APT-PCP: pHarvard Automated Phone

  2. Automated jitter correction for IR image processing to assess the quality of W7-X high heat flux components

    International Nuclear Information System (INIS)

    Greuner, H; De Marne, P; Herrmann, A; Boeswirth, B; Schindler, T; Smirnow, M

    2009-01-01

    An automated IR image processing method was developed to evaluate the surface temperature distribution of cyclically loaded high heat flux (HHF) plasma facing components. IPP Garching will perform the HHF testing of a high percentage of the series production of the WENDELSTEIN 7-X (W7-X) divertor targets to minimize the number of undiscovered uncertainties in the finally installed components. The HHF tests will be performed as quality assurance (QA) complementary to the non-destructive examination (NDE) methods used during the manufacturing. The IR analysis of an HHF-loaded component detects growing debonding of the plasma facing material, made of carbon fibre composite (CFC), after a few thermal cycles. In the case of the prototype testing, the IR data was processed manually. However, a QA method requires a reliable, reproducible and efficient automated procedure. Using the example of the HHF testing of W7-X pre-series target elements, the paper describes the developed automated IR image processing method. The algorithm is based on an iterative two-step correlation analysis with an individually defined reference pattern for the determination of the jitter.

  3. Possibilities of the common research-development action in the field of automated logistical engines

    Directory of Open Access Journals (Sweden)

    Pap Lajos

    2003-12-01

    Full Text Available The paper briefly presents the R&D cooperation of the Department of Materials Handling and Logistics and Departments of Automation. The main fields of cooperation are introduced. Different kind of Linear Motor (hereafter LM drives are being developed and tested for warehouse and rolling conveyor systems. Modern control strategies using AI methods are being investigated and tested for Automated guide vehicle. Wireless communication methods are being searched and developed for mobile material handling devices. Application possibilities of voice recognition and image processing are being tested for control of material handling robots and devices. Application of process visualization programs are being developed and investigated. Multi-level industrial communication system is being developed for the laboratories of the cooperating departments.

  4. Methods for automated identification of informative behaviors in natural bioptic driving.

    Science.gov (United States)

    Luo, Gang; Peli, Eli

    2012-06-01

    Visually impaired people may legally drive if wearing bioptic telescopes in some developed countries. To address the controversial safety issue of the practice, we have developed a low-cost in-car recording system that can be installed in study participants' own vehicles to record their daily driving activities. We also developed a set of automated identification techniques of informative behaviors to facilitate efficient manual review of important segments submerged in the vast amount of uncontrolled data. Here, we present the methods and quantitative results of the detection performance for six types of driving maneuvers and behaviors that are important for bioptic driving: bioptic telescope use, turns, curves, intersections, weaving, and rapid stops. The testing data were collected from one normally sighted and two visually impaired subjects across multiple days. The detection rates ranged from 82% up to 100%, and the false discovery rates ranged from 0% to 13%. In addition, two human observers were able to interpret about 80% of targets viewed through the telescope. These results indicate that with appropriate data processing the low-cost system is able to provide reliable data for natural bioptic driving studies.

  5. Automated fibroglandular tissue segmentation and volumetric density estimation in breast MRI using an atlas-aided fuzzy C-means method

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Shandong; Weinstein, Susan P.; Conant, Emily F.; Kontos, Despina, E-mail: despina.kontos@uphs.upenn.edu [Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania 19104 (United States)

    2013-12-15

    Purpose: Breast magnetic resonance imaging (MRI) plays an important role in the clinical management of breast cancer. Studies suggest that the relative amount of fibroglandular (i.e., dense) tissue in the breast as quantified in MR images can be predictive of the risk for developing breast cancer, especially for high-risk women. Automated segmentation of the fibroglandular tissue and volumetric density estimation in breast MRI could therefore be useful for breast cancer risk assessment. Methods: In this work the authors develop and validate a fully automated segmentation algorithm, namely, an atlas-aided fuzzy C-means (FCM-Atlas) method, to estimate the volumetric amount of fibroglandular tissue in breast MRI. The FCM-Atlas is a 2D segmentation method working on a slice-by-slice basis. FCM clustering is first applied to the intensity space of each 2D MR slice to produce an initial voxelwise likelihood map of fibroglandular tissue. Then a prior learned fibroglandular tissue likelihood atlas is incorporated to refine the initial FCM likelihood map to achieve enhanced segmentation, from which the absolute volume of the fibroglandular tissue (|FGT|) and the relative amount (i.e., percentage) of the |FGT| relative to the whole breast volume (FGT%) are computed. The authors' method is evaluated by a representative dataset of 60 3D bilateral breast MRI scans (120 breasts) that span the full breast density range of the American College of Radiology Breast Imaging Reporting and Data System. The automated segmentation is compared to manual segmentation obtained by two experienced breast imaging radiologists. Segmentation performance is assessed by linear regression, Pearson's correlation coefficients, Student's pairedt-test, and Dice's similarity coefficients (DSC). Results: The inter-reader correlation is 0.97 for FGT% and 0.95 for |FGT|. When compared to the average of the two readers’ manual segmentation, the proposed FCM-Atlas method achieves a

  6. Automated fibroglandular tissue segmentation and volumetric density estimation in breast MRI using an atlas-aided fuzzy C-means method

    International Nuclear Information System (INIS)

    Wu, Shandong; Weinstein, Susan P.; Conant, Emily F.; Kontos, Despina

    2013-01-01

    Purpose: Breast magnetic resonance imaging (MRI) plays an important role in the clinical management of breast cancer. Studies suggest that the relative amount of fibroglandular (i.e., dense) tissue in the breast as quantified in MR images can be predictive of the risk for developing breast cancer, especially for high-risk women. Automated segmentation of the fibroglandular tissue and volumetric density estimation in breast MRI could therefore be useful for breast cancer risk assessment. Methods: In this work the authors develop and validate a fully automated segmentation algorithm, namely, an atlas-aided fuzzy C-means (FCM-Atlas) method, to estimate the volumetric amount of fibroglandular tissue in breast MRI. The FCM-Atlas is a 2D segmentation method working on a slice-by-slice basis. FCM clustering is first applied to the intensity space of each 2D MR slice to produce an initial voxelwise likelihood map of fibroglandular tissue. Then a prior learned fibroglandular tissue likelihood atlas is incorporated to refine the initial FCM likelihood map to achieve enhanced segmentation, from which the absolute volume of the fibroglandular tissue (|FGT|) and the relative amount (i.e., percentage) of the |FGT| relative to the whole breast volume (FGT%) are computed. The authors' method is evaluated by a representative dataset of 60 3D bilateral breast MRI scans (120 breasts) that span the full breast density range of the American College of Radiology Breast Imaging Reporting and Data System. The automated segmentation is compared to manual segmentation obtained by two experienced breast imaging radiologists. Segmentation performance is assessed by linear regression, Pearson's correlation coefficients, Student's pairedt-test, and Dice's similarity coefficients (DSC). Results: The inter-reader correlation is 0.97 for FGT% and 0.95 for |FGT|. When compared to the average of the two readers’ manual segmentation, the proposed FCM-Atlas method achieves a correlation ofr = 0

  7. [Development of an automated processing method to detect coronary motion for coronary magnetic resonance angiography].

    Science.gov (United States)

    Asou, Hiroya; Imada, N; Sato, T

    2010-06-20

    On coronary MR angiography (CMRA), cardiac motions worsen the image quality. To improve the image quality, detection of cardiac especially for individual coronary motion is very important. Usually, scan delay and duration were determined manually by the operator. We developed a new evaluation method to calculate static time of individual coronary artery. At first, coronary cine MRI was taken at the level of about 3 cm below the aortic valve (80 images/R-R). Chronological change of the signals were evaluated with Fourier transformation of each pixel of the images were done. Noise reduction with subtraction process and extraction process were done. To extract higher motion such as coronary arteries, morphological filter process and labeling process were added. Using these imaging processes, individual coronary motion was extracted and individual coronary static time was calculated automatically. We compared the images with ordinary manual method and new automated method in 10 healthy volunteers. Coronary static times were calculated with our method. Calculated coronary static time was shorter than that of ordinary manual method. And scan time became about 10% longer than that of ordinary method. Image qualities were improved in our method. Our automated detection method for coronary static time with chronological Fourier transformation has a potential to improve the image quality of CMRA and easy processing.

  8. Participation through Automation: Fully Automated Critical PeakPricing in Commercial Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Piette, Mary Ann; Watson, David S.; Motegi, Naoya; Kiliccote,Sila; Linkugel, Eric

    2006-06-20

    California electric utilities have been exploring the use of dynamic critical peak prices (CPP) and other demand response programs to help reduce peaks in customer electric loads. CPP is a tariff design to promote demand response. Levels of automation in DR can be defined as follows: Manual Demand Response involves a potentially labor-intensive approach such as manually turning off or changing comfort set points at each equipment switch or controller. Semi-Automated Demand Response involves a pre-programmed demand response strategy initiated by a person via centralized control system. Fully Automated Demand Response does not involve human intervention, but is initiated at a home, building, or facility through receipt of an external communications signal. The receipt of the external signal initiates pre-programmed demand response strategies. They refer to this as Auto-DR. This paper describes the development, testing, and results from automated CPP (Auto-CPP) as part of a utility project in California. The paper presents the project description and test methodology. This is followed by a discussion of Auto-DR strategies used in the field test buildings. They present a sample Auto-CPP load shape case study, and a selection of the Auto-CPP response data from September 29, 2005. If all twelve sites reached their maximum saving simultaneously, a total of approximately 2 MW of DR is available from these twelve sites that represent about two million ft{sup 2}. The average DR was about half that value, at about 1 MW. These savings translate to about 0.5 to 1.0 W/ft{sup 2} of demand reduction. They are continuing field demonstrations and economic evaluations to pursue increasing penetrations of automated DR that has demonstrated ability to provide a valuable DR resource for California.

  9. Towards a Development Environment for Model Based Test Design

    OpenAIRE

    Jing, Han

    2008-01-01

    Within the UP IP I&V organization there is high focus on increasing the ability to predict product quality in a cost efficient way. Test automation has therefore been an important enabler for us. The IP test design environment is continuously evolving and the investigations will show which improvements that is most important to implement in short and long term. In Ericsson UP IP I&V, the test automation framework environments are severed to complete some process by automated method, f...

  10. Novel automated blood separations validate whole cell biomarkers.

    Directory of Open Access Journals (Sweden)

    Douglas E Burger

    Full Text Available Progress in clinical trials in infectious disease, autoimmunity, and cancer is stymied by a dearth of successful whole cell biomarkers for peripheral blood lymphocytes (PBLs. Successful biomarkers could help to track drug effects at early time points in clinical trials to prevent costly trial failures late in development. One major obstacle is the inaccuracy of Ficoll density centrifugation, the decades-old method of separating PBLs from the abundant red blood cells (RBCs of fresh blood samples.To replace the Ficoll method, we developed and studied a novel blood-based magnetic separation method. The magnetic method strikingly surpassed Ficoll in viability, purity and yield of PBLs. To reduce labor, we developed an automated platform and compared two magnet configurations for cell separations. These more accurate and labor-saving magnet configurations allowed the lymphocytes to be tested in bioassays for rare antigen-specific T cells. The automated method succeeded at identifying 79% of patients with the rare PBLs of interest as compared with Ficoll's uniform failure. We validated improved upfront blood processing and show accurate detection of rare antigen-specific lymphocytes.Improving, automating and standardizing lymphocyte detections from whole blood may facilitate development of new cell-based biomarkers for human diseases. Improved upfront blood processes may lead to broad improvements in monitoring early trial outcome measurements in human clinical trials.

  11. Novel automated blood separations validate whole cell biomarkers.

    Science.gov (United States)

    Burger, Douglas E; Wang, Limei; Ban, Liqin; Okubo, Yoshiaki; Kühtreiber, Willem M; Leichliter, Ashley K; Faustman, Denise L

    2011-01-01

    Progress in clinical trials in infectious disease, autoimmunity, and cancer is stymied by a dearth of successful whole cell biomarkers for peripheral blood lymphocytes (PBLs). Successful biomarkers could help to track drug effects at early time points in clinical trials to prevent costly trial failures late in development. One major obstacle is the inaccuracy of Ficoll density centrifugation, the decades-old method of separating PBLs from the abundant red blood cells (RBCs) of fresh blood samples. To replace the Ficoll method, we developed and studied a novel blood-based magnetic separation method. The magnetic method strikingly surpassed Ficoll in viability, purity and yield of PBLs. To reduce labor, we developed an automated platform and compared two magnet configurations for cell separations. These more accurate and labor-saving magnet configurations allowed the lymphocytes to be tested in bioassays for rare antigen-specific T cells. The automated method succeeded at identifying 79% of patients with the rare PBLs of interest as compared with Ficoll's uniform failure. We validated improved upfront blood processing and show accurate detection of rare antigen-specific lymphocytes. Improving, automating and standardizing lymphocyte detections from whole blood may facilitate development of new cell-based biomarkers for human diseases. Improved upfront blood processes may lead to broad improvements in monitoring early trial outcome measurements in human clinical trials.

  12. Automated PCB Inspection System

    Directory of Open Access Journals (Sweden)

    Syed Usama BUKHARI

    2017-05-01

    Full Text Available Development of an automated PCB inspection system as per the need of industry is a challenging task. In this paper a case study is presented, to exhibit, a proposed system for an immigration process of a manual PCB inspection system to an automated PCB inspection system, with a minimal intervention on the existing production flow, for a leading automotive manufacturing company. A detailed design of the system, based on computer vision followed by testing and analysis was proposed, in order to aid the manufacturer in the process of automation.

  13. Automated pure-tone audiometry: an analysis of capacity, need, and benefit.

    Science.gov (United States)

    Margolis, Robert H; Morgan, Donald E

    2008-12-01

    The rationale for automating pure-tone audiometry based on the need for hearing tests and the capacity of audiologists to provide testing is presented. The personnel time savings from automated testing are analyzed. Some possible effects of automated testing on the profession are explored. Need for testing was based on prevalence of hearing impairment, number of normal hearing patients seen for testing, and an assumption of the frequency of testing. Capacity is based on the number of audiologists and the number of audiograms performed in a typical workday. Time savings were estimated from the average duration of an audiogram and an assumption that 80% can be automated. A large gap exists between the need and the capacity of audiologists to provide testing. Automating 80% of audiograms would only partially close the gap. A significant time savings could accrue, permitting reallocation of time for doctoral level services. Although certain jobs could be affected, the gap between capacity and need is so great that automated audiometry will not significantly affect employment. Automation could increase the number of hearing impaired patients that could be served. The reallocation of personnel time would be a positive change for our patients and our profession.

  14. Adaptation of a T3-uptake test and of radioimmunoassays for serum digoxin, thyroxine, and triiodothyronine to an automated radioimmunoassay system: ''Centria''

    International Nuclear Information System (INIS)

    Ertingshausen, G.; Shapiro, S.I.; Green, G.; Zborowski, G.

    1975-01-01

    We report the adaptation of four radioassays to the prototype of an automated radioimmunoassay system (''Centria,'' Union Carbide). The system consists of three integrated modules: an automated pipettor, which dispenses samples and reagents; the key module, an incubator/separator, in which centrifugal force is used to initiate and terminate multiple radioassay incubations and separations simultaneously; and a gamma-counter/computer, which counts three tubes simultaneously and converts counts into concentration units. Radioimmunoassays for thyroxine, triiodothyronine, and digoxin were developed with use of well-characterized antibodies and of prepackaged Sephadex-containing columns to separate bound and free radioactive ligand. A triiodothyronine-uptake test in which the same kind of columns were used was also adapted to the instrument. Results for clinical samples compared favorably with those obtained by manual procedures. We report data on correlation between different methods and preliminary data on precision of the prototype system

  15. Feasibility of Commercially Available, Fully Automated Hepatic CT Volumetry for Assessing Both Total and Territorial Liver Volumes in Liver Transplantation

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Cheong Il; Kim, Se Hyung; Rhim, Jung Hyo; Yi, Nam Joon; Suh, Kyung Suk; Lee, Jeong Min; Han, Joon Koo; Choi, Byung Ihn [Seoul National University Hospital, Seoul (Korea, Republic of)

    2013-02-15

    To assess the feasibility of commercially-available, fully automated hepatic CT volumetry for measuring both total and territorial liver volumes by comparing with interactive manual volumetry and measured ex-vivo liver volume. For the assessment of total and territorial liver volume, portal phase CT images of 77 recipients and 107 donors who donated right hemiliver were used. Liver volume was measured using both the fully automated and interactive manual methods with Advanced Liver Analysis software. The quality of the automated segmentation was graded on a 4-point scale. Grading was performed by two radiologists in consensus. For the cases with excellent-to-good quality, the accuracy of automated volumetry was compared with interactive manual volumetry and measured ex-vivo liver volume which was converted from weight using analysis of variance test and Pearson's or Spearman correlation test. Processing time for both automated and interactive manual methods was also compared. Excellent-to-good quality of automated segmentation for total liver and right hemiliver was achieved in 57.1% (44/77) and 17.8% (19/107), respectively. For both total and right hemiliver volumes, there were no significant differences among automated, manual, and ex-vivo volumes except between automate volume and manual volume of the total liver (p = 0.011). There were good correlations between automate volume and ex-vivo liver volume ({gamma}= 0.637 for total liver and {gamma}= 0.767 for right hemiliver). Both correlation coefficients were higher than those with manual method. Fully automated volumetry required significantly less time than interactive manual method (total liver: 48.6 sec vs. 53.2 sec, right hemiliver: 182 sec vs. 244.5 sec). Fully automated hepatic CT volumetry is feasible and time-efficient for total liver volume measurement. However, its usefulness for territorial liver volumetry needs to be improved.

  16. Feasibility of Commercially Available, Fully Automated Hepatic CT Volumetry for Assessing Both Total and Territorial Liver Volumes in Liver Transplantation

    International Nuclear Information System (INIS)

    Shin, Cheong Il; Kim, Se Hyung; Rhim, Jung Hyo; Yi, Nam Joon; Suh, Kyung Suk; Lee, Jeong Min; Han, Joon Koo; Choi, Byung Ihn

    2013-01-01

    To assess the feasibility of commercially-available, fully automated hepatic CT volumetry for measuring both total and territorial liver volumes by comparing with interactive manual volumetry and measured ex-vivo liver volume. For the assessment of total and territorial liver volume, portal phase CT images of 77 recipients and 107 donors who donated right hemiliver were used. Liver volume was measured using both the fully automated and interactive manual methods with Advanced Liver Analysis software. The quality of the automated segmentation was graded on a 4-point scale. Grading was performed by two radiologists in consensus. For the cases with excellent-to-good quality, the accuracy of automated volumetry was compared with interactive manual volumetry and measured ex-vivo liver volume which was converted from weight using analysis of variance test and Pearson's or Spearman correlation test. Processing time for both automated and interactive manual methods was also compared. Excellent-to-good quality of automated segmentation for total liver and right hemiliver was achieved in 57.1% (44/77) and 17.8% (19/107), respectively. For both total and right hemiliver volumes, there were no significant differences among automated, manual, and ex-vivo volumes except between automate volume and manual volume of the total liver (p = 0.011). There were good correlations between automate volume and ex-vivo liver volume (γ= 0.637 for total liver and γ= 0.767 for right hemiliver). Both correlation coefficients were higher than those with manual method. Fully automated volumetry required significantly less time than interactive manual method (total liver: 48.6 sec vs. 53.2 sec, right hemiliver: 182 sec vs. 244.5 sec). Fully automated hepatic CT volumetry is feasible and time-efficient for total liver volume measurement. However, its usefulness for territorial liver volumetry needs to be improved.

  17. Automated gravity gradient tensor inversion for underwater object detection

    International Nuclear Information System (INIS)

    Wu, Lin; Tian, Jinwen

    2010-01-01

    Underwater abnormal object detection is a current need for the navigation security of autonomous underwater vehicles (AUVs). In this paper, an automated gravity gradient tensor inversion algorithm is proposed for the purpose of passive underwater object detection. Full-tensor gravity gradient anomalies induced by an object in the partial area can be measured with the technique of gravity gradiometry on an AUV. Then the automated algorithm utilizes the anomalies, using the inverse method to estimate the mass and barycentre location of the arbitrary-shaped object. A few tests on simple synthetic models will be illustrated, in order to evaluate the feasibility and accuracy of the new algorithm. Moreover, the method is applied to a complicated model of an abnormal object with gradiometer and AUV noise, and interference from a neighbouring illusive smaller object. In all cases tested, the estimated mass and barycentre location parameters are found to be in good agreement with the actual values

  18. Combining Archetypes, Ontologies and Formalization Enables Automated Computation of Quality Indicators.

    Science.gov (United States)

    Legaz-García, María Del Carmen; Dentler, Kathrin; Fernández-Breis, Jesualdo Tomás; Cornet, Ronald

    2017-01-01

    ArchMS is a framework that represents clinical information and knowledge using ontologies in OWL, which facilitates semantic interoperability and thereby the exploitation and secondary use of clinical data. However, it does not yet support the automated assessment of quality of care. CLIF is a stepwise method to formalize quality indicators. The method has been implemented in the CLIF tool which supports its users in generating computable queries based on a patient data model which can be based on archetypes. To enable the automated computation of quality indicators using ontologies and archetypes, we tested whether ArchMS and the CLIF tool can be integrated. We successfully automated the process of generating SPARQL queries from quality indicators that have been formalized with CLIF and integrated them into ArchMS. Hence, ontologies and archetypes can be combined for the execution of formalized quality indicators.

  19. Interpreting complex data by methods of recognition and classification in an automated system of aerogeophysical material processing

    Energy Technology Data Exchange (ETDEWEB)

    Koval' , L.A.; Dolgov, S.V.; Liokumovich, G.B.; Ovcharenko, A.V.; Priyezzhev, I.I.

    1984-01-01

    The system of automated processing of aerogeophysical data, ASOM-AGS/YeS, is equipped with complex interpretation of multichannel measurements. Algorithms of factor analysis, automatic classification and apparatus of a priori specified (selected) decisive rules are used. The areas of effect of these procedures can be initially limited to the specified geological information. The possibilities of the method are demonstrated by the results of automated processing of the aerogram-spectrometric measurements in the region of the known copper-porphyr manifestation in Kazakhstan. This ore deposit was clearly noted after processing by the method of main components by complex aureole of independent factors U (severe increase), Th (noticeable increase), K (decrease).

  20. Automation of On-Board Flightpath Management

    Science.gov (United States)

    Erzberger, H.

    1981-01-01

    The status of concepts and techniques for the design of onboard flight path management systems is reviewed. Such systems are designed to increase flight efficiency and safety by automating the optimization of flight procedures onboard aircraft. After a brief review of the origins and functions of such systems, two complementary methods are described for attacking the key design problem, namely, the synthesis of efficient trajectories. One method optimizes en route, the other optimizes terminal area flight; both methods are rooted in optimal control theory. Simulation and flight test results are reviewed to illustrate the potential of these systems for fuel and cost savings.

  1. Migration monitoring with automated technology

    Science.gov (United States)

    Rhonda L. Millikin

    2005-01-01

    Automated technology can supplement ground-based methods of migration monitoring by providing: (1) unbiased and automated sampling; (2) independent validation of current methods; (3) a larger sample area for landscape-level analysis of habitat selection for stopover, and (4) an opportunity to study flight behavior. In particular, radar-acoustic sensor fusion can...

  2. Comparison of the Cellient(™) automated cell block system and agar cell block method.

    Science.gov (United States)

    Kruger, A M; Stevens, M W; Kerley, K J; Carter, C D

    2014-12-01

    To compare the Cellient(TM) automated cell block system with the agar cell block method in terms of quantity and quality of diagnostic material and morphological, histochemical and immunocytochemical features. Cell blocks were prepared from 100 effusion samples using the agar method and Cellient system, and routinely sectioned and stained for haematoxylin and eosin and periodic acid-Schiff with diastase (PASD). A preliminary immunocytochemical study was performed on selected cases (27/100 cases). Sections were evaluated using a three-point grading system to compare a set of morphological parameters. Statistical analysis was performed using Fisher's exact test. Parameters assessing cellularity, presence of single cells and definition of nuclear membrane, nucleoli, chromatin and cytoplasm showed a statistically significant improvement on Cellient cell blocks compared with agar cell blocks (P cell groups, PASD staining or the intensity or clarity of immunocytochemical staining. A discrepant immunocytochemistry (ICC) result was seen in 21% (13/63) of immunostains. The Cellient technique is comparable with the agar method, with statistically significant results achieved for important morphological features. It demonstrates potential as an alternative cell block preparation method which is relevant for the rapid processing of fine needle aspiration samples, malignant effusions and low-cellularity specimens, where optimal cell morphology and architecture are essential. Further investigation is required to optimize immunocytochemical staining using the Cellient method. © 2014 John Wiley & Sons Ltd.

  3. Rapid, automated, nonradiometric susceptibility testing of Mycobacterium tuberculosis complex to four first-line antituberculous drugs used in standard short-course chemotherapy

    DEFF Research Database (Denmark)

    Johansen, Isik Somuncu; Thomsen, Vibeke Østergaard; Marjamäki, Merja

    2004-01-01

    The increasing prevalence of drug-resistant tuberculosis necessitates rapid and accurate susceptibility testing. The nonradiometric BACTEC Mycobacteria Growth Indicator Tube 960 (MGIT) system for susceptibility testing was evaluated on 222 clinical Mycobacterium tuberculosis complex isolates...... for isoniazid, rifampin, and ethambutol. Fifty-seven of the isolates were tested for pyrazinamide. Results were compared to those of radiometric BACTEC 460 system and discrepancies were resolved by the agar proportion method. We found an overall agreement of 99.0% for isoniazid, 99.5% for rifampin, 98.......2% for ethambutol, and 100% for pyrazinamide. After resolution of discrepancies, MGIT yielded no false susceptibility for rifampin and isoniazid. Although turnaround times were comparable, MGIT provides an advantage as inoculation can be done on any weekday as the growth is monitored automatically. The automated...

  4. A Parallel Multiblock Structured Grid Method with Automated Interblocked Unstructured Grids for Chemically Reacting Flows

    Science.gov (United States)

    Spiegel, Seth Christian

    An automated method for using unstructured grids to patch non- C0 interfaces between structured blocks has been developed in conjunction with a finite-volume method for solving chemically reacting flows on unstructured grids. Although the standalone unstructured solver, FVFLO-NCSU, is capable of resolving flows for high-speed aeropropulsion devices with complex geometries, unstructured-mesh algorithms are inherently inefficient when compared to their structured counterparts. However, the advantages of structured algorithms in developing a flow solution in a timely manner can be negated by the amount of time required to develop a mesh for complex geometries. The global domain can be split up into numerous smaller blocks during the grid-generation process to alleviate some of the difficulties in creating these complex meshes. An even greater abatement can be found by allowing the nodes on abutting block interfaces to be nonmatching or non-C 0 continuous. One code capable of solving chemically reacting flows on these multiblock grids is VULCAN, which uses a nonconservative approach for patching non-C0 block interfaces. The developed automated unstructured-grid patching algorithm has been installed within VULCAN to provide it the capability of a fully conservative approach for patching non-C0 block interfaces. Additionally, the FVFLO-NCSU solver algorithms have been deeply intertwined with the VULCAN source code to solve chemically reacting flows on these unstructured patches. Finally, the CGNS software library was added to the VULCAN postprocessor so structured and unstructured data can be stored in a single compact file. This final upgrade to VULCAN has been successfully installed and verified using test cases with particular interest towards those involving grids with non- C0 block interfaces.

  5. Statistical analysis to assess automated level of suspicion scoring methods in breast ultrasound

    Science.gov (United States)

    Galperin, Michael

    2003-05-01

    A well-defined rule-based system has been developed for scoring 0-5 the Level of Suspicion (LOS) based on qualitative lexicon describing the ultrasound appearance of breast lesion. The purposes of the research are to asses and select one of the automated LOS scoring quantitative methods developed during preliminary studies in benign biopsies reduction. The study has used Computer Aided Imaging System (CAIS) to improve the uniformity and accuracy of applying the LOS scheme by automatically detecting, analyzing and comparing breast masses. The overall goal is to reduce biopsies on the masses with lower levels of suspicion, rather that increasing the accuracy of diagnosis of cancers (will require biopsy anyway). On complex cysts and fibroadenoma cases experienced radiologists were up to 50% less certain in true negatives than CAIS. Full correlation analysis was applied to determine which of the proposed LOS quantification methods serves CAIS accuracy the best. This paper presents current results of applying statistical analysis for automated LOS scoring quantification for breast masses with known biopsy results. It was found that First Order Ranking method yielded most the accurate results. The CAIS system (Image Companion, Data Companion software) is developed by Almen Laboratories and was used to achieve the results.

  6. Low resolution spectroscopic investigation of Am stars using Automated method

    Science.gov (United States)

    Sharma, Kaushal; Joshi, Santosh; Singh, Harinder P.

    2018-04-01

    The automated method of full spectrum fitting gives reliable estimates of stellar atmospheric parameters (Teff, log g and [Fe/H]) for late A, F, G, and early K type stars. Recently, the technique was further improved in the cooler regime and the validity range was extended up to a spectral type of M6 - M7 (Teff˜ 2900 K). The present study aims to explore the application of this method on the low-resolution spectra of Am stars, a class of chemically peculiar stars, to examine its robustness for these objects. We use ULySS with the Medium-resolution INT Library of Empirical Spectra (MILES) V2 spectral interpolator for parameter determination. The determined Teff and log g values are found to be in good agreement with those obtained from high-resolution spectroscopy.

  7. Development and validation of an automated, microscopy-based method for enumeration of groups of intestinal bacteria

    NARCIS (Netherlands)

    Jansen, GJ; Wildeboer-Veloo, ACM; Tonk, RHJ; Franks, AH; Welling, G

    An automated microscopy-based method using fluorescently labelled 16S rRNA-targeted oligonucleotide probes directed against the predominant groups of intestinal bacteria was developed and validated. The method makes use of the Leica 600HR. image analysis system, a Kodak MegaPlus camera model 1.4 and

  8. ANA Testing: What should we know about the methods, indication and interpretation?

    Directory of Open Access Journals (Sweden)

    Au Elaine Yuen Ling

    2017-11-01

    Full Text Available Though ANA is a common test requested in several settings, one may not be aware of the potential traps for interpretation. Nowadays, there is a trend for autoantibodies diagnostics to move from traditional time honored manual methods to high throughput automated platforms. Nevertheless, the clinical significance and assay performance characteristics may be different from those “historical” methods. Though indirect immunofluorescence is the gold standard method for ANA tests, different laboratories vary in the slides (from different cell lines and commercial source, e.g., Hep 2, Hep 2000, etc., screening dilutions, terminology, reporting format and expertise. Hence, discrepancy in results among different laboratories is not uncommon and could be confusing. Knowing the assay characteristic and limitations helps proper results interpretation and facilitate patient’s management. Indeed, the titer and pattern by indirect immunofluorescence do provide valuable information in screening patients. In particular, DFS pattern with the associated anti-DFS70 antibodies has been shown to have a role to risk stratify cases referred for suspected autoimmune rheumatic disease.

  9. Automated replication of cone beam CT-guided treatments in the Pinnacle(3) treatment planning system for adaptive radiotherapy.

    Science.gov (United States)

    Hargrave, Catriona; Mason, Nicole; Guidi, Robyn; Miller, Julie-Anne; Becker, Jillian; Moores, Matthew; Mengersen, Kerrie; Poulsen, Michael; Harden, Fiona

    2016-03-01

    Time-consuming manual methods have been required to register cone-beam computed tomography (CBCT) images with plans in the Pinnacle(3) treatment planning system in order to replicate delivered treatments for adaptive radiotherapy. These methods rely on fiducial marker (FM) placement during CBCT acquisition or the image mid-point to localise the image isocentre. A quality assurance study was conducted to validate an automated CBCT-plan registration method utilising the Digital Imaging and Communications in Medicine (DICOM) Structure Set (RS) and Spatial Registration (RE) files created during online image-guided radiotherapy (IGRT). CBCTs of a phantom were acquired with FMs and predetermined setup errors using various online IGRT workflows. The CBCTs, DICOM RS and RE files were imported into Pinnacle(3) plans of the phantom and the resulting automated CBCT-plan registrations were compared to existing manual methods. A clinical protocol for the automated method was subsequently developed and tested retrospectively using CBCTs and plans for six bladder patients. The automated CBCT-plan registration method was successfully applied to thirty-four phantom CBCT images acquired with an online 0 mm action level workflow. Ten CBCTs acquired with other IGRT workflows required manual workarounds. This was addressed during the development and testing of the clinical protocol using twenty-eight patient CBCTs. The automated CBCT-plan registrations were instantaneous, replicating delivered treatments in Pinnacle(3) with errors of ±0.5 mm. These errors were comparable to mid-point-dependant manual registrations but superior to FM-dependant manual registrations. The automated CBCT-plan registration method quickly and reliably replicates delivered treatments in Pinnacle(3) for adaptive radiotherapy.

  10. An automated LS(β)- NaI(Tl)(γ) coincidence system as absolute standard for radioactivity measurements.

    Science.gov (United States)

    Joseph, Leena; Das, A P; Ravindra, Anuradha; Kulkarni, D B; Kulkarni, M S

    2018-07-01

    4πβ-γ coincidence method is a powerful and widely used method to determine the absolute activity concentration of radioactive solutions. A new automated liquid scintillator based coincidence system has been designed, developed, tested and established as absolute standard for radioactivity measurements. The automation is achieved using PLC (programmable logic controller) and SCADA (supervisory control and data acquisition). Radioactive solution of 60 Co was standardized to compare the performance of the automated system with proportional counter based absolute standard maintained in the laboratory. The activity concentrations determined using these two systems were in very good agreement; the new automated system can be used for absolute measurement of activity concentration of radioactive solutions. Copyright © 2018. Published by Elsevier Ltd.

  11. Automated washing of FTA Card punches and PCR setup for reference samples using a LIMS-controlled Sias Xantus automated liquid handler

    DEFF Research Database (Denmark)

    Stangegaard, Michael; Olsen, Addie Nina; Frøslev, Tobias G.

    2009-01-01

    We have implemented and validated automated methods for washing FTA Card punches containing buccal samples and subsequent PCR setup using a Sias Xantus automated liquid handler. The automated methods were controlled by worklists generated by our LabWare Laboratory Information Management System...

  12. Automated optical testing of LWIR objective lenses using focal plane array sensors

    Science.gov (United States)

    Winters, Daniel; Erichsen, Patrik; Domagalski, Christian; Peter, Frank; Heinisch, Josef; Dumitrescu, Eugen

    2012-10-01

    The image quality of today's state-of-the-art IR objective lenses is constantly improving while at the same time the market for thermography and vision grows strongly. Because of increasing demands on the quality of IR optics and increasing production volumes, the standards for image quality testing increase and tests need to be performed in shorter time. Most high-precision MTF testing equipment for the IR spectral bands in use today relies on the scanning slit method that scans a 1D detector over a pattern in the image generated by the lens under test, followed by image analysis to extract performance parameters. The disadvantages of this approach are that it is relatively slow, it requires highly trained operators for aligning the sample and the number of parameters that can be extracted is limited. In this paper we present lessons learned from the R and D process on using focal plane array (FPA) sensors for testing of long-wave IR (LWIR, 8-12 m) optics. Factors that need to be taken into account when switching from scanning slit to FPAs are e.g.: the thermal background from the environment, the low scene contrast in the LWIR, the need for advanced image processing algorithms to pre-process camera images for analysis and camera artifacts. Finally, we discuss 2 measurement systems for LWIR lens characterization that we recently developed with different target applications: 1) A fully automated system suitable for production testing and metrology that uses uncooled microbolometer cameras to automatically measure MTF (on-axis and at several o-axis positions) and parameters like EFL, FFL, autofocus curves, image plane tilt, etc. for LWIR objectives with an EFL between 1 and 12mm. The measurement cycle time for one sample is typically between 6 and 8s. 2) A high-precision research-grade system using again an uncooled LWIR camera as detector, that is very simple to align and operate. A wide range of lens parameters (MTF, EFL, astigmatism, distortion, etc.) can be

  13. Automated Search-Based Robustness Testing for Autonomous Vehicle Software

    Directory of Open Access Journals (Sweden)

    Kevin M. Betts

    2016-01-01

    Full Text Available Autonomous systems must successfully operate in complex time-varying spatial environments even when dealing with system faults that may occur during a mission. Consequently, evaluating the robustness, or ability to operate correctly under unexpected conditions, of autonomous vehicle control software is an increasingly important issue in software testing. New methods to automatically generate test cases for robustness testing of autonomous vehicle control software in closed-loop simulation are needed. Search-based testing techniques were used to automatically generate test cases, consisting of initial conditions and fault sequences, intended to challenge the control software more than test cases generated using current methods. Two different search-based testing methods, genetic algorithms and surrogate-based optimization, were used to generate test cases for a simulated unmanned aerial vehicle attempting to fly through an entryway. The effectiveness of the search-based methods in generating challenging test cases was compared to both a truth reference (full combinatorial testing and the method most commonly used today (Monte Carlo testing. The search-based testing techniques demonstrated better performance than Monte Carlo testing for both of the test case generation performance metrics: (1 finding the single most challenging test case and (2 finding the set of fifty test cases with the highest mean degree of challenge.

  14. Automated quality control in a file-based broadcasting workflow

    Science.gov (United States)

    Zhang, Lina

    2014-04-01

    Benefit from the development of information and internet technologies, television broadcasting is transforming from inefficient tape-based production and distribution to integrated file-based workflows. However, no matter how many changes have took place, successful broadcasting still depends on the ability to deliver a consistent high quality signal to the audiences. After the transition from tape to file, traditional methods of manual quality control (QC) become inadequate, subjective, and inefficient. Based on China Central Television's full file-based workflow in the new site, this paper introduces an automated quality control test system for accurate detection of hidden troubles in media contents. It discusses the system framework and workflow control when the automated QC is added. It puts forward a QC criterion and brings forth a QC software followed this criterion. It also does some experiments on QC speed by adopting parallel processing and distributed computing. The performance of the test system shows that the adoption of automated QC can make the production effective and efficient, and help the station to achieve a competitive advantage in the media market.

  15. Automated building of organometallic complexes from 3D fragments.

    Science.gov (United States)

    Foscato, Marco; Venkatraman, Vishwesh; Occhipinti, Giovanni; Alsberg, Bjørn K; Jensen, Vidar R

    2014-07-28

    A method for the automated construction of three-dimensional (3D) molecular models of organometallic species in design studies is described. Molecular structure fragments derived from crystallographic structures and accurate molecular-level calculations are used as 3D building blocks in the construction of multiple molecular models of analogous compounds. The method allows for precise control of stereochemistry and geometrical features that may otherwise be very challenging, or even impossible, to achieve with commonly available generators of 3D chemical structures. The new method was tested in the construction of three sets of active or metastable organometallic species of catalytic reactions in the homogeneous phase. The performance of the method was compared with those of commonly available methods for automated generation of 3D models, demonstrating higher accuracy of the prepared 3D models in general, and, in particular, a much wider range with respect to the kind of chemical structures that can be built automatically, with capabilities far beyond standard organic and main-group chemistry.

  16. Development, field testing and implementation of automated hydraulically controlled, variable volume loading systems for reciprocating compressors

    Energy Technology Data Exchange (ETDEWEB)

    Hickman, Dwayne A. [ACI Services, Inc., Cambridge, OH (United States); Slupsky, John [Kvaerner Process Systems, Calgary, Alberta (Canada); Chrisman, Bruce M.; Hurley, Tom J. [Cooper Energy Services, Oklahoma City, OK (United States). Ajax Division

    2003-07-01

    Automated, variable volume unloaders provide the ability to smoothly load/unload reciprocating compressors to maintain ideal operations in ever-changing environments. Potential advantages provided by this load control system include: maximizing unit capacity, optimizing power economy, maintaining low exhaust emissions, and maintaining process suction and discharge pressures. Obstacles foreseen include: reliability, stability, serviceability and automation integration. Results desired include: increased productivity for the compressor and its operators, increased up time, and more stable process control. This presentation covers: system design features with descriptions of how different types of the devices were developed, initial test data, and how they can be effectively operated; three actual-case studies detailing the reasons why automated, hydraulically controlled, variable volume, head-end unloaders were chosen over other types of unloading devices; sophisticated software used in determining the device sizing and predicted performance; mechanical and field considerations; installation, serviceability and operating considerations; device control issues, including PC and PLC considerations; monitoring of actual performance and comparison of such with predicted performance; analysis of mechanical reliability and stability; and preliminary costs versus return on investment analysis. (author)

  17. Automation Diagnosis of Skin Disease in Humans using Dempster-Shafer Method

    Science.gov (United States)

    Khairina, Dyna Marisa; Hatta, Heliza Rahmania; Rustam; Maharani, Septya

    2018-02-01

    Skin disease is an infectious disease that is common in people of all ages. Disorders of the skin often occur because there are factors, among others, are climate, environment, shelter, unhealthy living habits, allergies and others. Skin diseases in Indonesia are mostly caused by bacterial, fungal, parasitic, and allergies. The objective of the research is to diagnose skin diseases in humans by using the method of making decision tree then performing the search by forward chaining and calculating the probability value of Dempster-Shafer method. The results of research in the form of an automated system that can resemble an expert in diagnosing skin disease accurately and can help in overcoming the problem of skin diseases.

  18. Model-Based Security Testing

    Directory of Open Access Journals (Sweden)

    Ina Schieferdecker

    2012-02-01

    Full Text Available Security testing aims at validating software system requirements related to security properties like confidentiality, integrity, authentication, authorization, availability, and non-repudiation. Although security testing techniques are available for many years, there has been little approaches that allow for specification of test cases at a higher level of abstraction, for enabling guidance on test identification and specification as well as for automated test generation. Model-based security testing (MBST is a relatively new field and especially dedicated to the systematic and efficient specification and documentation of security test objectives, security test cases and test suites, as well as to their automated or semi-automated generation. In particular, the combination of security modelling and test generation approaches is still a challenge in research and of high interest for industrial applications. MBST includes e.g. security functional testing, model-based fuzzing, risk- and threat-oriented testing, and the usage of security test patterns. This paper provides a survey on MBST techniques and the related models as well as samples of new methods and tools that are under development in the European ITEA2-project DIAMONDS.

  19. Manual and automation testing and verification of TEQ [ECI PROPIRETRY

    Science.gov (United States)

    Abhichandra, Ravi; Jasmine Pemeena Priyadarsini, M.

    2017-11-01

    The telecommunication industry has progressed from 1G to 4G and now 5G is gaining prominence. Given the pace of this abrupt transformation, technological obsolescence is becoming a serious issue to deal with. Adding to this fact is that the execution of each technology requires ample investment into network, infrastructure, development etc. As a result, the industry is becoming more dynamic and strategy oriented. It requires professionals who not only can understand technology but also can evaluate the same from a business perspective. The “Information Revolution” and the dramatic advances in telecommunications technology, which has made this possible, currently drive the global economy in large part. As wireless networks become more advanced and far-reaching, we are redefining the notion of connectivity and the possibilities of communications technology. In this paper I test and verify the optical cards and automate this test procedure by using a new in-house technology “TEQ” developed by ECI TELECOM which uses one the optical cards itself to pump traffic of 100gbps.

  20. Drilling Automation Demonstrations in Subsurface Exploration for Astrobiology

    Science.gov (United States)

    Glass, Brian; Cannon, H.; Lee, P.; Hanagud, S.; Davis, K.

    2006-01-01

    This project proposes to study subsurface permafrost microbial habitats at a relevant Arctic Mars-analog site (Haughton Crater, Devon Island, Canada) while developing and maturing the subsurface drilling and drilling automation technologies that will be required by post-2010 missions. It builds on earlier drilling technology projects to add permafrost and ice-drilling capabilities to 5m with a lightweight drill that will be automatically monitored and controlled in-situ. Frozen cores obtained with this drill under sterilized protocols will be used in testing three hypotheses pertaining to near-surface physical geology and ground H2O ice distribution, viewed as a habitat for microbial life in subsurface ice and ice-consolidated sediments. Automation technologies employed will demonstrate hands-off diagnostics and drill control, using novel vibrational dynamical analysis methods and model-based reasoning to monitor and identify drilling fault states before and during faults. Three field deployments, to a Mars-analog site with frozen impact crater fallback breccia, will support science goals, provide a rigorous test of drilling automation and lightweight permafrost drilling, and leverage past experience with the field site s particular logistics.

  1. Automated Quality Assurance of Medical Digital X-Ray Equipment

    International Nuclear Information System (INIS)

    Zelikman, Mikhail; Kruchinin, Sergey

    2013-06-01

    Quality assurance of the x-ray equipment includes a set of various tests among which are installation and periodic exams performed by qualified engineers as well as daily routine tests carried out by the medical staff of the Radiology Department. As a rule, the decision concerning the applicability of the x-ray equipment for using in clinical studies is made on the basis of the routine tests results. The presented method is based on the detector's output signals, Signal-to-Noise Ratio and Modulation Transfer Function evaluation in automated way using the simple test-object's digital image registered with given geometry and x-ray exposure parameters settings. Rectangular 20 mm thick aluminum plate with fixed 1 mm thick well-finished steel edge (for general x-ray radiography/fluoroscopy systems) or 2 mm thick aluminum plate with fixed 1 mm thick aluminum well-finished edge (for digital x-ray mammography systems) can be used as a test equipment. Relevant to the decision concerning the x-ray device operation status are the parameters: deviations from the reference levels of the tube voltage and mAs as well as internal detector's noise variance and detector's gain deviations. Everyday testing procedure includes the following steps. On the first step the roentgenographer places the test-object at the center of the detector's surface, makes an exposure with specified parameters setting and geometry and after this, test results are displayed on the work station monitor or console screen in automatic way. In order to provide an automated regime of the presenting algorithm, the software must be integrated with the program module intended for the x-ray device control. The use of the presented method in clinical practice provides the reliable daily monitoring of the x-ray equipment operation status prior to its utilizing for patient diagnostic process. As a rule, it will take not more than 3-5 minutes for the roentgenographer to complete the routine

  2. Optimization of automation: II. Estimation method of ostracism rate based on the loss of situation awareness of human operators in nuclear power plants

    International Nuclear Information System (INIS)

    Lee, Seung Min; Kim, Man Cheol; Kim, Jong Hyun; Seong, Poong Hyun

    2015-01-01

    Highlights: • We analyze the relationship between Out-of-the-Loop and the loss of human operators’ situation awareness. • We propose an ostracism rate estimation method by only considering the negative effects of automation. • The ostracism rate reflects how much automation interrupts human operators to receive information. • The higher the ostracism rate is, the lower the accuracy of human operators’ SA will be. - Abstract: With the introduction of automation in various industries including the nuclear field, its side effect, referred to as the Out-of-the-Loop (OOTL) problem, has emerged as a critical issue that needs to be addressed. Many studies have been attempted to analyze and solve the OOTL problem, but this issue still needs a clear solution to provide criteria for introducing automation. Therefore, a quantitative estimation method for identifying negative effects of automation is proposed in this paper. The representative aspect of the OOTL problem in nuclear power plants (NPPs) is that human operators in automated operations are given less information than human operators in manual operations. In other words, human operators have less opportunity to obtain needed information as automation is introduced. From this point of view, the degree of difficulty in obtaining information from automated systems is defined as the Level of Ostracism (LOO). Using the LOO and information theory, we propose the ostracism rate, which is a new estimation method that expresses how much automation interrupts human operators’ situation awareness. We applied production rules to describe the human operators’ thinking processes, Bayesian inference to describe the production rules mathematically, and information theory to calculate the amount of information that human operators receive through observations. The validity of the suggested method was proven by conducting an experiment. The results show that the ostracism rate was significantly related to the accuracy

  3. 75 FR 3253 - Lamb Assembly and Test, LLC, Subsidiary of Mag Industrial Automation Systems, Machesney Park, IL...

    Science.gov (United States)

    2010-01-20

    ... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-70,516] Lamb Assembly and Test, LLC, Subsidiary of Mag Industrial Automation Systems, Machesney Park, IL; Notice of Negative... workers of Lamb Technicon, a division of Unova, Warren, Michigan and Lake Orion, Michigan were previously...

  4. State-of-the-art methods for testing materials outdoors

    Science.gov (United States)

    R. Sam Williams

    2004-01-01

    In recent years, computers, sensors, microelectronics, and communication technologies have made it possible to automate the way materials are tested in the field. It is now possible to purchase monitoring equipment to measure weather and materials properties. The measurement of materials response often requires innovative approaches and added expense, but the...

  5. Streamlining and automation of radioanalytical methods at a commercial laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Harvey, J.T.; Dillard, J.W. [IT Corp., Knoxville, TN (United States)

    1993-12-31

    Through the careful planning and design of laboratory facilities and incorporation of modern instrumentation and robotics systems, properly trained and competent laboratory associates can efficiently and safely handle radioactive and mixed waste samples. This paper addresses the potential improvements radiochemistry and mixed waste laboratories can achieve utilizing robotics for automated sample analysis. Several examples of automated systems for sample preparation and analysis will be discussed.

  6. Streamlining and automation of radioanalytical methods at a commercial laboratory

    International Nuclear Information System (INIS)

    Harvey, J.T.; Dillard, J.W.

    1993-01-01

    Through the careful planning and design of laboratory facilities and incorporation of modern instrumentation and robotics systems, properly trained and competent laboratory associates can efficiently and safely handle radioactive and mixed waste samples. This paper addresses the potential improvements radiochemistry and mixed waste laboratories can achieve utilizing robotics for automated sample analysis. Several examples of automated systems for sample preparation and analysis will be discussed

  7. Evaluation of an automated microplate technique in the Galileo system for ABO and Rh(D) blood grouping.

    Science.gov (United States)

    Xu, Weiyi; Wan, Feng; Lou, Yufeng; Jin, Jiali; Mao, Weilin

    2014-01-01

    A number of automated devices for pretransfusion testing have recently become available. This study evaluated the Immucor Galileo System, a fully automated device based on the microplate hemagglutination technique for ABO/Rh (D) determinations. Routine ABO/Rh typing tests were performed on 13,045 samples using the Immucor automated instruments. Manual tube method was used to resolve ABO forward and reverse grouping discrepancies. D-negative test results were investigated and confirmed manually by the indirect antiglobulin test (IAT). The system rejected 70 tests for sample inadequacy. 87 samples were read as "No-type-determined" due to forward and reverse grouping discrepancies. 25 tests gave these results because of sample hemolysis. After further tests, we found 34 tests were caused by weakened RBC antibodies, 5 tests were attributable to weak A and/or B antigens, 4 tests were due to mixed-field reactions, and 8 tests had high titer cold agglutinin with blood qualifications which react only at temperatures below 34 degrees C. In the remaining 11 cases, irregular RBC antibodies were identified in 9 samples (seven anti-M and two anti-P) and two subgroups were identified in 2 samples (one A1 and one A2) by a reference laboratory. As for D typing, 2 weak D+ samples missed by automated systems gave negative results, but weak-positive reactions were observed in the IAT. The Immucor Galileo System is reliable and suited for ABO and D blood groups, some reasons may cause a discrepancy in ABO/D typing using a fully automated system. It is suggested that standardization of sample collection may improve the performance of the fully automated system.

  8. Test-retest reliability and longitudinal analysis of automated hippocampal subregion volumes in healthy ageing and Alzheimer's disease populations.

    Science.gov (United States)

    Worker, Amanda; Dima, Danai; Combes, Anna; Crum, William R; Streffer, Johannes; Einstein, Steven; Mehta, Mitul A; Barker, Gareth J; C R Williams, Steve; O'daly, Owen

    2018-04-01

    The hippocampal formation is a complex brain structure that is important in cognitive processes such as memory, mood, reward processing and other executive functions. Histological and neuroimaging studies have implicated the hippocampal region in neuropsychiatric disorders as well as in neurodegenerative diseases. This highly plastic limbic region is made up of several subregions that are believed to have different functional roles. Therefore, there is a growing interest in imaging the subregions of the hippocampal formation rather than modelling the hippocampus as a homogenous structure, driving the development of new automated analysis tools. Consequently, there is a pressing need to understand the stability of the measures derived from these new techniques. In this study, an automated hippocampal subregion segmentation pipeline, released as a developmental version of Freesurfer (v6.0), was applied to T1-weighted magnetic resonance imaging (MRI) scans of 22 healthy older participants, scanned on 3 separate occasions and a separate longitudinal dataset of 40 Alzheimer's disease (AD) patients. Test-retest reliability of hippocampal subregion volumes was assessed using the intra-class correlation coefficient (ICC), percentage volume difference and percentage volume overlap (Dice). Sensitivity of the regional estimates to longitudinal change was estimated using linear mixed effects (LME) modelling. The results show that out of the 24 hippocampal subregions, 20 had ICC scores of 0.9 or higher in both samples; these regions include the molecular layer, granule cell layer of the dentate gyrus, CA1, CA3 and the subiculum (ICC > 0.9), whilst the hippocampal fissure and fimbria had lower ICC scores (0.73-0.88). Furthermore, LME analysis of the independent AD dataset demonstrated sensitivity to group and individual differences in the rate of volume change over time in several hippocampal subregions (CA1, molecular layer, CA3, hippocampal tail, fissure and presubiculum

  9. Automated extraction protocol for quantification of SARS-Coronavirus RNA in serum: an evaluation study

    Directory of Open Access Journals (Sweden)

    Lui Wing-bong

    2006-02-01

    Full Text Available Abstract Background We have previously developed a test for the diagnosis and prognostic assessment of the severe acute respiratory syndrome (SARS based on the detection of the SARS-coronavirus RNA in serum by real-time quantitative reverse transcriptase polymerase chain reaction (RT-PCR. In this study, we evaluated the feasibility of automating the serum RNA extraction procedure in order to increase the throughput of the assay. Methods An automated nucleic acid extraction platform using the MagNA Pure LC instrument (Roche Diagnostics was evaluated. We developed a modified protocol in compliance with the recommended biosafety guidelines from the World Health Organization based on the use of the MagNA Pure total nucleic acid large volume isolation kit for the extraction of SARS-coronavirus RNA. The modified protocol was compared with a column-based extraction kit (QIAamp viral RNA mini kit, Qiagen for quantitative performance, analytical sensitivity and precision. Results The newly developed automated protocol was shown to be free from carry-over contamination and have comparable performance with other standard protocols and kits designed for the MagNA Pure LC instrument. However, the automated method was found to be less sensitive, less precise and led to consistently lower serum SARS-coronavirus concentrations when compared with the column-based extraction method. Conclusion As the diagnostic efficiency and prognostic value of the serum SARS-CoV RNA RT-PCR test is critically associated with the analytical sensitivity and quantitative performance contributed both by the RNA extraction and RT-PCR components of the test, we recommend the use of the column-based manual RNA extraction method.

  10. Reproducibility of Automated Voice Range Profiles, a Systematic Literature Review

    DEFF Research Database (Denmark)

    Printz, Trine; Rosenberg, Tine; Godballe, Christian

    2018-01-01

    literature on test-retest accuracy of the automated voice range profile assessment. Study design: Systematic review. Data sources: PubMed, Scopus, Cochrane Library, ComDisDome, Embase, and CINAHL (EBSCO). Methods: We conducted a systematic literature search of six databases from 1983 to 2016. The following...

  11. Automated Method for Monitoring Water Quality Using Landsat Imagery

    Directory of Open Access Journals (Sweden)

    D. Clay Barrett

    2016-06-01

    Full Text Available Regular monitoring of water quality is increasingly necessary to keep pace with rapid environmental change and protect human health and well-being. Remote sensing has been suggested as a potential solution for monitoring certain water quality parameters without the need for in situ sampling, but universal methods and tools are lacking. While many studies have developed predictive relationships between remotely sensed surface reflectance and water parameters, these relationships are often unique to a particular geographic region and have little applicability in other areas. In order to remotely monitor water quality, these relationships must be developed on a region by region basis. This paper presents an automated method for processing remotely sensed images from Landsat Thematic Mapper (TM and Enhanced Thematic Mapper Plus (ETM+ and extracting corrected reflectance measurements around known sample locations to allow rapid development of predictive water quality relationships to improve remote monitoring. Using open Python scripting, this study (1 provides an openly accessible and simple method for processing publicly available remote sensing data; and (2 allows determination of relationships between sampled water quality parameters and reflectance values to ultimately allow predictive monitoring. The method is demonstrated through a case study of the Ozark/Ouchita-Appalachian ecoregion in eastern Oklahoma using data collected for the Beneficial Use Monitoring Program (BUMP.

  12. The Automated DC Parameter Testing of GaAs MESFETs Using the Singer Automatic Integrated Circuit Test System.

    Science.gov (United States)

    1980-09-01

    USING THE SINGER AUTOMATIC INTEGRATED CIRCUIT TEST SYSTEM, THOMAS L. HARPER AFIT/EE/GE/80- 7 Ist LT USAF -- -- - - __ AFIT/EE/GE/80-7 THE AUTOMATED DC...THOMAS L. HARPER ist Lt USAF Graduate Electrical Engineering September 1980 it’ Codes A _ _ _ J PREFACE This report is in support of the ongoing effort in...8217.-- I *t -1 ,p - tUel-, ir. ( /.s , j Yf) L) b ..... l P i:. +’ ,T i~: ",,’+l l L V i i ,’b : O Iil r, P V 47 C’+t ( ’ I ViH 47 V ’L 4 £, ,.;l 1 , h

  13. Sunglass detection method for automation of video surveillance system

    Science.gov (United States)

    Sikandar, Tasriva; Samsudin, Wan Nur Azhani W.; Hawari Ghazali, Kamarul; Mohd, Izzeldin I.; Fazle Rabbi, Mohammad

    2018-04-01

    Wearing sunglass to hide face from surveillance camera is a common activity in criminal incidences. Therefore, sunglass detection from surveillance video has become a demanding issue in automation of security systems. In this paper we propose an image processing method to detect sunglass from surveillance images. Specifically, a unique feature using facial height and width has been employed to identify the covered region of the face. The presence of covered area by sunglass is evaluated using facial height-width ratio. Threshold value of covered area percentage is used to classify the glass wearing face. Two different types of glasses have been considered i.e. eye glass and sunglass. The results of this study demonstrate that the proposed method is able to detect sunglasses in two different illumination conditions such as, room illumination as well as in the presence of sunlight. In addition, due to the multi-level checking in facial region, this method has 100% accuracy of detecting sunglass. However, in an exceptional case where fabric surrounding the face has similar color as skin, the correct detection rate was found 93.33% for eye glass.

  14. Laboratory automation and LIMS in forensics

    DEFF Research Database (Denmark)

    Stangegaard, Michael; Hansen, Anders Johannes; Morling, Niels

    2013-01-01

    . Furthermore, implementation of automated liquid handlers reduces the risk of sample misplacement. A LIMS can efficiently control the sample flow through the laboratory and manage the results of the conducted tests for each sample. Integration of automated liquid handlers with a LIMS provides the laboratory......Implementation of laboratory automation and LIMS in a forensic laboratory enables the laboratory, to standardize sample processing. Automated liquid handlers can increase throughput and eliminate manual repetitive pipetting operations, known to result in occupational injuries to the technical staff...... with the tools required for setting up automated production lines of complex laboratory processes and monitoring the whole process and the results. Combined, this enables processing of a large number of samples. Selection of the best automated solution for an individual laboratory should be based on user...

  15. Colorimetric determination of nitrate plus nitrite in water by enzymatic reduction, automated discrete analyzer methods

    Science.gov (United States)

    Patton, Charles J.; Kryskalla, Jennifer R.

    2011-01-01

    This report documents work at the U.S. Geological Survey (USGS) National Water Quality Laboratory (NWQL) to validate enzymatic reduction, colorimetric determinative methods for nitrate + nitrite in filtered water by automated discrete analysis. In these standard- and low-level methods (USGS I-2547-11 and I-2548-11), nitrate is reduced to nitrite with nontoxic, soluble nitrate reductase rather than toxic, granular, copperized cadmium used in the longstanding USGS automated continuous-flow analyzer methods I-2545-90 (NWQL laboratory code 1975) and I-2546-91 (NWQL laboratory code 1979). Colorimetric reagents used to determine resulting nitrite in aforementioned enzymatic- and cadmium-reduction methods are identical. The enzyme used in these discrete analyzer methods, designated AtNaR2 by its manufacturer, is produced by recombinant expression of the nitrate reductase gene from wall cress (Arabidopsis thaliana) in the yeast Pichia pastoris. Unlike other commercially available nitrate reductases we evaluated, AtNaR2 maintains high activity at 37°C and is not inhibited by high-phenolic-content humic acids at reaction temperatures in the range of 20°C to 37°C. These previously unrecognized AtNaR2 characteristics are essential for successful performance of discrete analyzer nitrate + nitrite assays (henceforth, DA-AtNaR2) described here.

  16. Automated methods for single-stranded DNA isolation and dideoxynucleotide DNA sequencing reactions on a robotic workstation

    International Nuclear Information System (INIS)

    Mardis, E.R.; Roe, B.A.

    1989-01-01

    Automated procedures have been developed for both the simultaneous isolation of 96 single-stranded M13 chimeric template DNAs in less than two hours, and for simultaneously pipetting 24 dideoxynucleotide sequencing reactions on a commercially available laboratory workstation. The DNA sequencing results obtained by either radiolabeled or fluorescent methods are consistent with the premise that automation of these portions of DNA sequencing projects will improve the reproducibility of the DNA isolation and the procedures for these normally labor-intensive steps provides an approach for rapid acquisition of large amounts of high quality, reproducible DNA sequence data

  17. Automated logic conversion method for plant controller systems

    International Nuclear Information System (INIS)

    Wada, Yutaka; Kobayashi, Yasuhiro; Miyo, Tsunemasa; Okano, Masato.

    1990-01-01

    An automated method is proposed for logic conversion from functional description diagrams to detailed logic schematics by incorporating expertise knowledge in plant controller systems design. The method uses connection data of function elements in the functional description diagram as input, and synthesizes a detailed logic structure by adding elements to the given connection data incrementally, and to generate detailed logic schematics. In logic synthesis, for building up complex synthesis procedures by combining generally-described knowledge, knowledge is applied by groups. The search order of the groups is given by upper-level knowledge. Furthermore, the knowledge is expressed in terms of two classes of rules; one for generating a hypothesis of individual synthesis operations and the other for considering several hypotheses to determine the connection ordering of elements to be added. In the generation of detailed logic schematics, knowledge is used as rules for deriving various kinds of layout conditions on schematics, and rules for generating two-dimensional coordinates of layout objects. Rules in the latter class use layout conditions to predict intersections among layout objects without their coordinates being fixed. The effectiveness of the method with 150 rules was verified by its experimental application to some logic conversions in a real power plant design. Evaluation of the results showed them to be equivalent to those obtained by well qualified designers. (author)

  18. A two-dimensionally coincident second difference cosmic ray spike removal method for the fully automated processing of Raman spectra.

    Science.gov (United States)

    Schulze, H Georg; Turner, Robin F B

    2014-01-01

    Charge-coupled device detectors are vulnerable to cosmic rays that can contaminate Raman spectra with positive going spikes. Because spikes can adversely affect spectral processing and data analyses, they must be removed. Although both hardware-based and software-based spike removal methods exist, they typically require parameter and threshold specification dependent on well-considered user input. Here, we present a fully automated spike removal algorithm that proceeds without requiring user input. It is minimally dependent on sample attributes, and those that are required (e.g., standard deviation of spectral noise) can be determined with other fully automated procedures. At the core of the method is the identification and location of spikes with coincident second derivatives along both the spectral and spatiotemporal dimensions of two-dimensional datasets. The method can be applied to spectra that are relatively inhomogeneous because it provides fairly effective and selective targeting of spikes resulting in minimal distortion of spectra. Relatively effective spike removal obtained with full automation could provide substantial benefits to users where large numbers of spectra must be processed.

  19. Performance analysis of automated evaluation of Crithidia luciliae-based indirect immunofluorescence tests in a routine setting - strengths and weaknesses.

    Science.gov (United States)

    Hormann, Wymke; Hahn, Melanie; Gerlach, Stefan; Hochstrate, Nicola; Affeldt, Kai; Giesen, Joyce; Fechner, Kai; Damoiseaux, Jan G M C

    2017-11-27

    Antibodies directed against dsDNA are a highly specific diagnostic marker for the presence of systemic lupus erythematosus and of particular importance in its diagnosis. To assess anti-dsDNA antibodies, the Crithidia luciliae-based indirect immunofluorescence test (CLIFT) is one of the assays considered to be the best choice. To overcome the drawback of subjective result interpretation that inheres indirect immunofluorescence assays in general, automated systems have been introduced into the market during the last years. Among these systems is the EUROPattern Suite, an advanced automated fluorescence microscope equipped with different software packages, capable of automated pattern interpretation and result suggestion for ANA, ANCA and CLIFT analysis. We analyzed the performance of the EUROPattern Suite with its automated fluorescence interpretation for CLIFT in a routine setting, reflecting the everyday life of a diagnostic laboratory. Three hundred and twelve consecutive samples were collected, sent to the Central Diagnostic Laboratory of the Maastricht University Medical Centre with a request for anti-dsDNA analysis over a period of 7 months. Agreement between EUROPattern assay analysis and the visual read was 93.3%. Sensitivity and specificity were 94.1% and 93.2%, respectively. The EUROPattern Suite performed reliably and greatly supported result interpretation. Automated image acquisition is readily performed and automated image classification gives a reliable recommendation for assay evaluation to the operator. The EUROPattern Suite optimizes workflow and contributes to standardization between different operators or laboratories.

  20. European conference on nondestructive testing

    Energy Technology Data Exchange (ETDEWEB)

    Klyuev, V V

    1985-01-01

    Information on the 3-d European conference on nondestructive testing (NT) held in October, 1984 in Florence, is presented. Plenary reports were devoted to complex use of different NT methods, tendencies to NT automation and robotics, transition from defectoscopy to quality control, determination of phisico-mechanical properties of items using different control methods, formulation of unified international programs on professional training and qualification. Section reports cover the following directions: NT use in aviation and astronautics, construction, welding engineering, studying works of art; personnel training, economics, NT functioning, automation, calibration, standardization, quality control over metallic and nonmetallic objects. Some reports concerned nondestructive testing of items during their use. Attention is paied to radiographic testing and neutron radiography as well as to image processing. NT equipment was also discussed.