WorldWideScience

Sample records for test assembly quality

  1. Tritium systems test assembly quality assurance program

    International Nuclear Information System (INIS)

    Kerstiens, F.L.; Wilhelm, R.C.

    1986-07-01

    A quality assurance program should establish the planned and systematic actions necessary to provide adequate confidence that fusion facilities and their subsystems will perform satisfactorily in service. The Tritium Systems Test Assembly (TSTA) Quality Assurance Program has been designed to assure that the designs, tests, data, and interpretive reports developed at TSTA are valid, accurate, and consistent with formally specified procedures and reviews. The quality consideration in all TSTA activities is directed toward the early detection of quality problems, coupled with timely and positive disposition and corrective action

  2. Image quality testing of assembled IR camera modules

    Science.gov (United States)

    Winters, Daniel; Erichsen, Patrik

    2013-10-01

    Infrared (IR) camera modules for the LWIR (8-12_m) that combine IR imaging optics with microbolometer focal plane array (FPA) sensors with readout electronics are becoming more and more a mass market product. At the same time, steady improvements in sensor resolution in the higher priced markets raise the requirement for imaging performance of objectives and the proper alignment between objective and FPA. This puts pressure on camera manufacturers and system integrators to assess the image quality of finished camera modules in a cost-efficient and automated way for quality control or during end-of-line testing. In this paper we present recent development work done in the field of image quality testing of IR camera modules. This technology provides a wealth of additional information in contrast to the more traditional test methods like minimum resolvable temperature difference (MRTD) which give only a subjective overall test result. Parameters that can be measured are image quality via the modulation transfer function (MTF) for broadband or with various bandpass filters on- and off-axis and optical parameters like e.g. effective focal length (EFL) and distortion. If the camera module allows for refocusing the optics, additional parameters like best focus plane, image plane tilt, auto-focus quality, chief ray angle etc. can be characterized. Additionally, the homogeneity and response of the sensor with the optics can be characterized in order to calculate the appropriate tables for non-uniformity correction (NUC). The technology can also be used to control active alignment methods during mechanical assembly of optics to high resolution sensors. Other important points that are discussed are the flexibility of the technology to test IR modules with different form factors, electrical interfaces and last but not least the suitability for fully automated measurements in mass production.

  3. Development of a quality-assurance program for the Tritium Systems Test Assembly

    International Nuclear Information System (INIS)

    Minor, R.C.

    1981-01-01

    A quality assurance program was developed for TSTA with the attempt in mind to satisfy the developmental nature of the project. Numerous reviews replace strict guidelines because guidelines are one of the objectives of the project, not a basis for it. The reviews assure adequate technical consideration and avoid unilateral decisions. Other major requirements of the program plan include interfacing with another quality assurance organization, the assignment of responsibilities, and instructions for the preparation of SDD's. Areas of concern are, in general, budget related, and include receiving inspection and acceptance of items. A software program is only now being established

  4. Test quality

    International Nuclear Information System (INIS)

    Hartley, R.S.; Keller, A.E.

    1992-01-01

    Inservice testing of safety-related components at nuclear power plants is performed under the American Society of Mechanical Engineers Boiler and Pressure Vessel Code (the Code). Subsections IWP and IWV of Section 11 of the Code state test method and frequency requirements for pumps and valves, respectively. Tests vary greatly in quality and frequency. This paper explores the concept of test quality and its relationship with operational readiness and preventive maintenance. This paper also considers the frequencies of component testing. Test quality is related to a test's ability to detect degradation that can cause component failure. The quality of the test depends on several factors, including specific parameters measured, system or component conditions, and instrument accuracy. The quality of some currently required tests for check valves, motor-operated valves, and pumps is also discussed. Suggestions are made to improve test quality by measuring different parameters, testing valves under load, and testing positive displacement pumps at high pressure and centrifugal pumps at high flow rate conditions. These suggestions can help to improve the level of assurance of component operational readiness gained from testing

  5. Test quality

    International Nuclear Information System (INIS)

    Hartley, R.S.; Keller, A.E.

    1992-01-01

    This document discusses inservice testing of safety-related components at nuclear power plants which is performed under the American Society of Mechanical Engineers Boiler and Pressure Vessel Code (the Code). Subsections IWP and IWV of Section XI of the Code state test method and frequency requirements for pumps and valves respectively. Tests vary greatly in quality and frequency. This paper explores the concept of test quality and its relationship with operational readiness and preventive maintenance. This paper also considers the frequencies of component testing. Test quality is related to a test's ability to detect degradation that can cause component failure. The quality of the test depends on several factors, including specific parameters measured, system or component conditions, and instrument accuracy. The quality of some currently required tests for check valves, motor-operated valves, and pumps is also discussed. Suggestions are made to improve test quality by measuring different parameters, testing valves under load, and testing positive displacement pumps at high pressure and centrifugal pumps at high flow rate conditions. These suggestions can help to improve the level of assurance of component operational readiness gained from testing

  6. FMIT Test assemblies. Progress report

    International Nuclear Information System (INIS)

    Nygren, R.E.; Opperman, E.K.

    1978-08-01

    This progress report is a reference document for a number of inter-related tasks supporting the Fusion Materials Irradiation Test (FMIT) Facility being developed by the Hanford Engineering Development Laboratory. The report describes the basic configuration of test assemblies and supporting rationale based on the neutron flux distribution. Perturbed and unperturbed flux profiles are discussed as well as heating rates and cooling requirements

  7. EFTF cobalt test assembly results

    International Nuclear Information System (INIS)

    Rawlins, J.A.; Wootan, D.W.; Carter, L.L.; Brager, H.R.; Schenter, R.E.

    1988-01-01

    A cobalt test assembly containing yttrium hydride pins for neutron moderation was irradiated in the Fast Flux Test Facility during Cycle 9A for 137.7 equivalent full power days at a power level fo 291 MW. The 36 test pins consisted of a batch of 32 pins containing cobalt metal to produce Co-60, and a set of 4 pins with europium oxide to produce Gd-153, a radioisotope used in detection of the bone disease Osteoporosis. Post-irradiation examination of the cobalt pins determined the Co-60 produced with an accuracy of about 5 %. The measured Co-60 spatially distributed concentrations were within 20 % of the calculated concentrations. The assembly average Co-60 measured activity was 4 % less than the calculated value. The europium oxide pins were gamma scanned for the europium isotopes Eu-152 and Eu-154 to an absolute accuracy of about 10 %. The measured europium radioisotpe anc Gd-153 concentrations were within 20 % of calculated values. In conclusion, the hydride assembly performed well and is an excellent vehicle for many Fast Flux Test Facility isotope production applications. The results also demonstrate that the calculational methods developed by the Westinghouse Hanford Company are very accurate. (author)

  8. Quality and reliability control on assemblies

    International Nuclear Information System (INIS)

    Mueller, H.

    1976-01-01

    Taking as an example electronic assemblies in printed circuit board engineering, quality control during manufacture is dealt with. After giving a survey of four phases of quality and reliability control, some specific methods of quality control are dealt with by means of a flowchart, and by some examples the necessity and the success of these measures are shown. (RW) [de

  9. QUAST: quality assessment tool for genome assemblies.

    Science.gov (United States)

    Gurevich, Alexey; Saveliev, Vladislav; Vyahhi, Nikolay; Tesler, Glenn

    2013-04-15

    Limitations of genome sequencing techniques have led to dozens of assembly algorithms, none of which is perfect. A number of methods for comparing assemblers have been developed, but none is yet a recognized benchmark. Further, most existing methods for comparing assemblies are only applicable to new assemblies of finished genomes; the problem of evaluating assemblies of previously unsequenced species has not been adequately considered. Here, we present QUAST-a quality assessment tool for evaluating and comparing genome assemblies. This tool improves on leading assembly comparison software with new ideas and quality metrics. QUAST can evaluate assemblies both with a reference genome, as well as without a reference. QUAST produces many reports, summary tables and plots to help scientists in their research and in their publications. In this study, we used QUAST to compare several genome assemblers on three datasets. QUAST tables and plots for all of them are available in the Supplementary Material, and interactive versions of these reports are on the QUAST website. http://bioinf.spbau.ru/quast . Supplementary data are available at Bioinformatics online.

  10. Reusable fuel test assembly for the FFTF

    International Nuclear Information System (INIS)

    Pitner, A.L.; Dittmer, J.O.

    1992-01-01

    A fuel test assembly that provides re-irradiation capability after interim discharge and reconstitution of the test pin bundle has been developed for use in the Fast Flux Test Facility (FFTF). This test vehicle permits irradiation test data to be obtained at multiple exposures on a few select test pins without the substantial expense of fabricating individual test assemblies as would otherwise be required. A variety of test pin types can be loaded in the reusable test assembly. A reusable test vehicle for irradiation testing in the FFTF has long been desired, but a number of obstacles previously prevented the implementation of such an experimental rig. The MFF-8A test assembly employs a 169-pin bundle using HT-9 alloy for duct and cladding material. The standard driver pins in the fuel bundle are sodium-bonded metal fuel (U-10 wt% Zr). Thirty-seven positions in the bundle are replaceable pin positions. Standard MFF-8A driver pins can be loaded in any test pin location to fill the bundle if necessary. Application of the MFF-8A reusable test assembly in the FFTF constitutes a considerable cost-saving measure with regard to irradiation testing. Only a few well-characterized test pins need be fabricated to conduct a test program rather than constructing entire test assemblies

  11. Quantifying quality in DNA self-assembly

    Science.gov (United States)

    Wagenbauer, Klaus F.; Wachauf, Christian H.; Dietz, Hendrik

    2014-01-01

    Molecular self-assembly with DNA is an attractive route for building nanoscale devices. The development of sophisticated and precise objects with this technique requires detailed experimental feedback on the structure and composition of assembled objects. Here we report a sensitive assay for the quality of assembly. The method relies on measuring the content of unpaired DNA bases in self-assembled DNA objects using a fluorescent de-Bruijn probe for three-base ‘codons’, which enables a comparison with the designed content of unpaired DNA. We use the assay to measure the quality of assembly of several multilayer DNA origami objects and illustrate the use of the assay for the rational refinement of assembly protocols. Our data suggests that large and complex objects like multilayer DNA origami can be made with high strand integration quality up to 99%. Beyond DNA nanotechnology, we speculate that the ability to discriminate unpaired from paired nucleic acids in the same macromolecule may also be useful for analysing cellular nucleic acids. PMID:24751596

  12. Quality Assessment of Domesticated Animal Genome Assemblies

    DEFF Research Database (Denmark)

    Seemann, Stefan E; Anthon, Christian; Palasca, Oana

    2015-01-01

    affected by the lack of genomic sequence. Herein, we quantify the quality of the genome assemblies of 20 domesticated animals and related species by assessing a range of measurable parameters, and we show that there is a positive correlation between the fraction of mappable reads from RNAseq data...... domesticated animal genomes still need to be sequenced deeper in order to produce high-quality assemblies. In the meanwhile, ironically, the extent to which RNAseq and other next-generation data is produced frequently far exceeds that of the genomic sequence. Furthermore, basic comparative analysis is often...

  13. Tritium systems test assembly stabilization

    International Nuclear Information System (INIS)

    Jasen, William G.; Michelotti, Roy A.; Anast, Kurt R.; Tesch, Charles

    2004-01-01

    The Tritium Systems Test Assembly (TSTA) was a facility dedicated to tritium technology Research and Development (R and D) primarily for future fusion power reactors. The facility was conceived in mid 1970's, operations commenced in early 1980's, stabilization and deactivation began in 2000 and were completed in 2003. The facility will remain in a Surveillance and Maintenance (S and M) mode until the Department of Energy (DOE) funds demolition of the facility, tentatively in 2009. A safe and stable end state was achieved by the TSTA Facility Stabilization Project (TFSP) in anticipation of long term S and M. At the start of the stabilization project, with an inventory of approximately 140 grams of tritium, the facility was designated a Hazard Category (HC) 2 Non-Reactor Nuclear facility as defined by US Department of Energy standard DOE-STD-1027-92 (1997). The TSTA facility comprises a laboratory area, supporting rooms, offices and associated laboratory space that included more than 20 major tritium handling systems. The project's focus was to reduce the tritium inventory by removing bulk tritium, tritiated water wastes, and tritium-contaminated high-inventory components. Any equipment that remained in the facility was stabilized in place. All of the gloveboxes and piping were rendered inoperative and vented to atmosphere. All equipment, and inventoried tritium contamination, remaining in the facility was left in a safe-and-stable state. The project used the End Points process as defined by the DOE Office of Environmental Management (web page http://www.em.doe.- gov/deact/epman.htmtlo) document and define the end state required for the stabilization of TSTA Facility. The End Points process added structure that was beneficial through virtually all phases of the project. At completion of the facility stabilization project the residual tritium inventory was approximately 3,000 curies, considerably less than the 1.6-gram threshold for a HC 3 facility. TSTA is now

  14. The NIRspec assembly integration and test status

    Science.gov (United States)

    Wettemann, Thomas; Ehrenwinkler, Ralf; Johnson, Thomas E.; Maschmann, Marc; Mosner, Peter; te Plate, Maurice; Rödel, Andreas

    2017-11-01

    The Near-Infrared Spectrograph (NIRSpec) is one of the four instruments on the James Webb Space Telescope (JWST) scheduled for launch in 2018. NIRSpec has been manufactured and tested by an European industrial consortium led by Airbus Defence and Space and delivered to the European Space Agency (ESA) and NASA in September 2013. Since then it has successfully been integrated into the JWST Integrated Science Instrument Module (ISIM) and is currently in ISIM Cryo-Vacuum Test#2. Since however two of its most important assemblies, the Focal Plane Assembly (FPA) and the Micro-Shutter Assembly (MSA) need to be replaced by new units we will present the status of the instrument, the status of its new flight assemblies in manufacturing and testing and give an outlook on the planned exchange activities and the following instrument re-verification.

  15. ATLAS silicon module assembly and qualification tests at IFIC Valencia

    International Nuclear Information System (INIS)

    Bernabeu, J; Civera, J V; Costa, M J; Escobar, C; Fuster, J; Garcia, C; Garcia-Navarro, J E; Gonzalez, F; Gonzalez-Sevilla, S; Lacasta, C; Llosa, G; Marti-Garcia, S; Minano, M; Mitsou, V A; Modesto, P; Nacher, J; Rodriguez-Oliete, R; Sanchez, F J; Sospedra, L; Strachko, V

    2007-01-01

    ATLAS experiment, designed to probe the interactions of particles emerging out of proton proton collisions at energies of up to 14 TeV, will assume operation at the Large Hadron Collider (LHC) at CERN in 2007. This paper discusses the assembly and the quality control tests of forward detector modules for the ATLAS silicon microstrip detector assembled at the Instituto de Fisica Corpuscular (IFIC) in Valencia. The construction and testing procedures are outlined and the laboratory equipment is briefly described. Emphasis is given on the module quality achieved in terms of mechanical and electrical stability

  16. SPECT quality control tests

    International Nuclear Information System (INIS)

    Robilotta, C.C.; Rebelo, M.F.S.; Oliveira, M.A.; Abe, R.

    1987-01-01

    Quality control tests of tomographic system composed by a rotatory chamber (CGR Gammatomome T-9000) and a microcomputer are presented. Traditional quality control tests for scintilation chambers and specific tests for tomographic systems are reported. (M.A.C.) [pt

  17. SP-100 nuclear assembly test: Test assembly functional requirements and system arrangement

    International Nuclear Information System (INIS)

    Fallas, T.T.; Gluck, R.; Motwani, K.; Clay, H.; O'Neill, G.

    1991-01-01

    This paper describes the functional requirements and the system that will be tested to validate the reactor, flight shield, and flight controller of the SP-100 Generic Flight System (GFS). The Nuclear Assembly Test (NAT) consists of the test article (SP-100 reactor with control devices and the flight shield) and its supporting systems. The NAT test assembly is being designed by GE. Westinghouse Hanford Company (WHC) is designing the test cell and vacuum vessel system that will contain the NAT test assembly (Renkey et al. 1989). Preliminary design reviews have been completed and the final design is under way

  18. TESS Lens-Bezel Assembly Modal Testing

    Science.gov (United States)

    Dilworth, Brandon J.; Karlicek, Alexandra

    2017-01-01

    The Transiting Exoplanet Survey Satellite (TESS) program, led by the Kavli Institute for Astrophysics and Space Research at the Massachusetts Institute of Technology (MIT) will be the first-ever spaceborne all-sky transit survey. MIT Lincoln Laboratory is responsible for the cameras, including the lens assemblies, detector assemblies, lens hoods, and camera mounts. TESS is scheduled to be launched in August of 2017 with the primary goal to detect small planets with bright host starts in the solar neighborhood, so that detailed characterizations of the planets and their atmospheres can be performed. The TESS payload consists of four identical cameras and a data handling unit. Each camera consists of a lens assembly with seven optical elements and a detector assembly with four charge-coupled devices (CCDs) including their associated electronics. The optical prescription requires that several of the lenses are in close proximity to a neighboring element. A finite element model (FEM) was developed to estimate the relative deflections between each lens-bezel assembly under launch loads to predict that there are adequate clearances preventing the lenses from making contact. Modal tests using non-contact response measurements were conducted to experimentally estimate the modal parameters of the lens-bezel assembly, and used to validate the initial FEM assumptions. Key Words Non-contact measurements, modal analysis, model validation

  19. MITG test assembly design and fabrication

    International Nuclear Information System (INIS)

    Schock, A.

    1983-01-01

    The design, analysis, and evaluation of the Modular Isotopic Thermoelectric Generator (MITG), described in an earlier paper, led to a program to build and test prototypical, modules of that generator. Each test module duplicates the thermoelectric converters, thermal insulation, housing and radiator fins of a typical generator slice, and simulates its isotope heat source module by means of an electrical heater encased in a prototypical graphite box. Once the approx. 20-watt MITG module has been developed, it can be assembled in appropriate number to form a generator design yielding the desired power output. The present paper describes the design and fabrication of the MITG test assembly, which confirmed the fabricability of the multicouples and interleaved multifoil insulation called for by the design. Test plans, procedures, instrumentation, results, and post-test analyses, as well as revised designs, fabrication procedures, and performance estimates, are described in subsequent papers in these proceedings

  20. Integrating Test-Form Formatting into Automated Test Assembly

    Science.gov (United States)

    Diao, Qi; van der Linden, Wim J.

    2013-01-01

    Automated test assembly uses the methodology of mixed integer programming to select an optimal set of items from an item bank. Automated test-form generation uses the same methodology to optimally order the items and format the test form. From an optimization point of view, production of fully formatted test forms directly from the item pool using…

  1. A hall for assembly and cryogenic tests

    International Nuclear Information System (INIS)

    Beaunier, J.; Buhler, S.; Caruette, A.; Chevrollier, R.; Junquera, T.; Le Scornet, J.C.

    1999-01-01

    Cryodrome, an assembly hall and the testing ground for cryogenic equipment and R and D experiments for the superconducting cavities is going to be transformed for its future missions. The cryogenic utilities, especially the He low pressure pumping capacity, was rearranged and extended to a new area. Space was provided to install CRYHOLAB, a new horizontal cryostat for cavity testing. Automatic control and supervision of the utilities and the experimental area are rebuilt and updated. (authors)

  2. Progress in FMIT test assembly development

    International Nuclear Information System (INIS)

    Opperman, E.K.; Vogel, M.A.; Shen, E.J.; Trego, A.L.

    1983-08-01

    Research and development supporting the completed design of the Fusion Materials Irradiation Test (FMIT) Facility is continuing at the Hanford Engineering Development Laboratory (HEDL) in Richland, Washington. The FMIT, a deuteron accelerator based (d + Li) neutron source, will produce an intense flux of high energy neutrons for use in radiation damage studies of fusion reactor materials. The most intense flux magnitude of greater than 10 15 n/cm 2 -s is located close to the neutron producing lithium target and is distributed within a volume about the size of an American football. The conceptual design and development of FMIT experiments called Test Assemblies has progressed over the past five years in parallel with the design of the FMIT. The paper will describe the recent accomplishments made in developing test assemblies appropriate for use in the limited volume close to the FMIT target where high neutron flux and heating rates and the associated spacial gradients significantly impact design considerations

  3. Methods and characteristics of assembly language software testing

    International Nuclear Information System (INIS)

    Wang Lingfang

    2001-01-01

    Single chip micro-controllers are widely implemented to the controlling and testing products in industrial controlling and national defence embedded controlling systems. The invalidation of the source programs could lead to the unreliability of the whole systems, even to cause fatal results. Therefore, software testing is the necessary measures to reduce the mistakes and to improve the quality of the software. In the paper, the development of the software testing is presented. The distinctions between the assembly language testing and those of the high level languages is introduced. And the essential flow and methods of software testing are discussed in detail

  4. Fluid flow test for KMRR fuel assemblies

    International Nuclear Information System (INIS)

    Chung, Moon Ki; Yang, Sun Kyu; Chung, Chang Hwan; Chun, See Young; Song, Chul Hha; Jun, Hyung Gil; Chung, Heung Joon; Won, Soon Yeun; Cho, Young Rho; Kim, Bok Deuk

    1991-01-01

    Hydraulic and velocity measurment tests were carried out for the KMRR fuel assembly. Two types of the KMRR fuel assembly are consist of longitudinally finned rods. Experimental data of the pressure drops and friction factors for the KMRR fuel assemlby were produced. The measurement technique for the turbulent flow structure in subchannels using the LDV was obtained. The measurement of the experimental constant of the thermal hydraulic analysis code was investigated. The results in this study are used as the basic data for the development of an analysis code. The measurement technique acquired in this study can be applied to the KMRR thermal hydraulic commissioning test and development of the domestic KMRR fuel fabrication. (Author)

  5. The TileCal Barrel Test Assembly

    CERN Multimedia

    Leitner, R

    On 30th October, the mechanics test assembly of the central barrel of the ATLAS tile hadronic calorimeter was completed in building 185. It started on 23rd June and is the second wheel for the Tilecal completely assembled this year. The ATLAS engineers and technicians are quick: instead of the 27 weeks initially foreseen for assembling the central barrel of the tile hadronic calorimeter (Tilecal) in building 185, they inserted the last of the 64 modules on 30th October after only 19 weeks. In part, this was due to the experience gained in the dry run assembly of the first extended barrel, produced in Spain, in spring this year (see Bulletin 23/2003); however, the central barrel is twice as long - and twice as heavy. With a length of 6.4 metres, an outer diameter of 8.5 metres and an inner diameter of 4.5 metres, the object weight is 1300 tonnes. The whole barrel cylinder is supported by the stainless steel support structure weighing only 27 tons. The barrel also has to have the right shape: over the whole 8...

  6. Technical operations procedure for assembly and emplacement of the soil temperature test--test assembly

    International Nuclear Information System (INIS)

    Weber, A.P.

    1978-01-01

    A description is given of the plan for assembly, instrumentation, emplacement, and operational checkout of the soil temperature test assembly and dry well liner. The activities described cover all operations necessary to accomplish the receiving inspection, instrumentation and pre-construction handling of the dry well liner, plus all operations performed with the test article. Actual details of construction work are not covered by this procedure. Each part and/or section of this procedure is a separate function to be accomplished as required by the nature of the operation. The organization of the procedure is not intended to imply a special operational sequence or schedular requirement. Specific procedure operational sections include: receiving inspection; liner assembly operations; construction operations (by others); prepare shield plug; test article assembly and installation; and operational checkout

  7. Test of GERDA Phase II detector assembly

    Energy Technology Data Exchange (ETDEWEB)

    Bode, Tobias; Gusev, Konstantin [Technische Universitaet Muenchen (Germany); Schwingenheuer, Bernhard; Wagner, Victoria [Max-Planck Institut fuer Kernphysik, Heidelberg (Germany); Collaboration: GERDA-Collaboration

    2014-07-01

    The GERDA experiment searches for the lepton number violating neutrinoless double beta decay (0νββ) of {sup 76}Ge. The experiment uses HPGe detectors enriched in {sup 76}Ge as source and detection material. In GERDA Phase I five BEGe detectors were operated successfully. These detectors are distinguished for improved energy resolution and enhanced pulse shape discrimination (PSD) against background events. In Phase II additional 25 BEGe detectors will be installed. New electronics and radio-pure low-mass holders were specially designed for Phase II. Prior to the installation in GERDA all BEGe detectors are tested in their final assembly in the LNGS underground laboratory. This talk presents the mechanics and performance of the GERDA Phase II detector assembly.

  8. New phenomena observed during fuel assemblies testing

    International Nuclear Information System (INIS)

    Tzotcheva, V.

    2001-01-01

    The paper presents a new attempt to explain inexplicable increase of specific activity for some of the fuel assemblies during the fuel tightness testing procedures on Kozloduy NPP. A brief description of established procedure for fuel tightness control is presented in the paper. Special emphasis is given on a hypothesis that explains the fact of existence of deviation in Iodine activity more than usual, which have no reasonable interpretation. The reasons for uniform high Iodine activity for reloaded assemblies, that have kept in the open measuring can for a long time (1-3 hours), is found to be the process of Iodine dissolving in the water and the accelerated process of natural degassing. A proposal to use the 134 Cs and 137 Cs as stand-alone criteria for more precise results is made in respect to increase the reliability of fuel reloading and storage procedures

  9. Assembly for testing weldability of sheet metal

    International Nuclear Information System (INIS)

    David, S.A.; Woodhouse, J.J.

    1985-01-01

    A test assembly for determining the weldability of sheet metal includes a base having a flat side surface with an annular groove in the side surface, a counterbore being formed in the outer wall of the groove and the surface portion of the base circumscribed by the inner wall of the groove being substantially coplanar with the bottom of the counterbore, a test disk of sheet metal the periphery of which is positioned in the counterbore and the outer surface of which is coplanar with one side of the base, and a clamp ring overlying the side surface of the base and the edge portion of the test disk and a plurality of clamp screws which extend through the clamp ring for holding the periphery of the test disk against the bottom of the counterbore

  10. Tritium Systems Test Assembly operator training program

    International Nuclear Information System (INIS)

    Kerstiens, F.L.

    1985-01-01

    Proper operator training is needed to help ensure the safe operation of fusion facilities by personnel who are qualified to carry out their assigned responsibilities. Operators control and monitor the Tritium Systems Test Assembly (TSTA) during normal, emergency, and maintenance phases. Their performance is critical both to operational safety, assuring no release of tritium to the atmosphere, and to the successful simulation of the fusion reaction progress. Through proper training we are helping assure that TSTA facility operators perform their assignments in a safe and efficient manner and that the operators maintain high levels of operational proficiency through continuing training, retraining, requalification, and recertification

  11. Severe accident testing of electrical penetration assemblies

    International Nuclear Information System (INIS)

    Clauss, D.B.

    1989-11-01

    This report describes the results of tests conducted on three different designs of full-size electrical penetration assemblies (EPAs) that are used in the containment buildings of nuclear power plants. The objective of the tests was to evaluate the behavior of the EPAs under simulated severe accident conditions using steam at elevated temperature and pressure. Leakage, temperature, and cable insulation resistance were monitored throughout the tests. Nuclear-qualified EPAs were produced from D. G. O'Brien, Westinghouse, and Conax. Severe-accident-sequence analysis was used to generate the severe accident conditions (SAC) for a large dry pressurized-water reactor (PWR), a boiling-water reactor (BWR) Mark I drywell, and a BWR Mark III wetwell. Based on a survey conducted by Sandia, each EPA was matched with the severe accident conditions for a specific reactor type. This included the type of containment that a particular EPA design was used in most frequently. Thus, the D. G. O'Brien EPA was chosen for the PWR SAC test, the Westinghouse was chosen for the Mark III test, and the Conax was chosen for the Mark I test. The EPAs were radiation and thermal aged to simulate the effects of a 40-year service life and loss-of-coolant accident (LOCA) before the SAC tests were conducted. The design, test preparations, conduct of the severe accident test, experimental results, posttest observations, and conclusions about the integrity and electrical performance of each EPA tested in this program are described in this report. In general, the leak integrity of the EPAs tested in this program was not compromised by severe accident loads. However, there was significant degradation in the insulation resistance of the cables, which could affect the electrical performance of equipment and devices inside containment at some point during the progression of a severe accident. 10 refs., 165 figs., 16 tabs

  12. Assembly, alignment and test of the Transiting Exoplanet Survey Satellite (TESS) optical assemblies

    Science.gov (United States)

    Balonek, Gregory; Brown, Joshua J.; Andre, James E.; Chesbrough, Christian D.; Chrisp, Michael P.; Dalpiaz, Michael; Lennon, Joseph; Richards, B. C.; Clark, Kristin E.

    2017-08-01

    The Transiting Exoplanet Survey Satellite (TESS) will carry four visible waveband, seven-element, refractive F/1.4 lenses, each with a 34 degree diagonal field of view. This paper describes the methods used for the assembly, alignment and test of the four flight optical assemblies. Prior to commencing the build of the four flight optical assemblies, a Risk Reduction Unit (RRU) was successfully assembled and tested [1]. The lessons learned from the RRU were applied to the build of the flight assemblies. The main modifications to the flight assemblies include the inking of the third lens element stray light mitigation, tighter alignment tolerances, and diamond turning for critical mechanical surfaces. Each of the optical assemblies was tested interferometrically and measured with a low coherence distance measuring interferometer (DMI) to predict the optimal shim thickness between the lens assembly and detector before -75°C environmental testing. In addition to individual test data, environmental test results from prior assemblies allow for the exploration of marginal performance differences between each of the optical assemblies.

  13. Electrical Quality Assurance of the Superconducting Circuits during LHC Machine Assembly

    CERN Document Server

    Bozzini, D; Desebe, O; Mess, K H; Russenschuck, Stephan; Bednarek, M; Dworak, D; Górnicki, E; Jurkiewicz, P; Kapusta, P; Kotarba, A; Ludwin, J; Olek, S; Talach, M; Zieblinski, M; Klisch, M; Prochal, B

    2008-01-01

    Based on the LHC powering reference database, all-together 1750 superconducting circuits were connected in the various cryogenic transfer lines of the LHC machine. Testing the continuity, magnet polarity, and the quality of the electrical insulation were the main tasks of the Electrical Quality Assurance (ELQA) activities during the LHC machine assembly. With the assembly of the LHC now complete, the paper reviews the work flow, resources, and the qualification results including the different types of electrical non-conformities.

  14. LEU WWR-M2 fuel assemblies burnable test

    International Nuclear Information System (INIS)

    Kirsanov, G.A.; Konoplev, K.A.; Pikulik, R.G.; Sajkov, Yu. P.; Tchmshkyan, D.V.; Tedoradze, L.V.; Zakharov, A.S.

    2000-01-01

    The results of in-pile irradiation tests of LEU WWR-M2 fuel assemblies with reduced enrichment of fuel are submitted in the report. The tests are made according to the Russian Program on Reduced Enrichment for Research and Test Reactors (RERTR). United States Department of Energy and the Ministry of Atomic Energy of Russian Federation jointly fund this Program. The irradiation tests of 5 WWR-M2 experimental assemblies are carried out at WWR-M reactor of the Petersburg Nuclear Physics Institute (PNPI). The information on assembly design and technique of irradiation tests is presented. In the irradiation tests the integrity of fuel assemblies is periodically measured. The report presents the data for the integrity maintained during the burnup of 5 fuel assemblies up to 45%. These results demonstrate the high reliability of the experimental fuel assemblies within the guaranteed burnup limits specified by the manufacturer. The tests are still in progress; it is planned to test and analyze the change in integrity for burnup of up to 70% - 75% or more. LEU WWR-M2 fuel assemblies are to be offered for export by their Novosibirsk manufacturer. Currently, HEU WWR-M2 fuel assemblies are used in Hungary, Ukraine and Vietnam. LEU WWR-M2 fuel assemblies were designed as a possible replacement for the HEU WWR-M2 fuel assemblies in those countries, but their use can be extended to other research reactors. (author)

  15. Development of quality assurance methods for low enriched fuel assemblies

    International Nuclear Information System (INIS)

    Woolstenhulme, N.E.; Moore, G.A.; Perez, D.M.; Wachs, D.M.

    2010-01-01

    As the Reduced Enrichment for Research and Test Reactors (RERTR) fuel development program has furthered the technology of low enriched uranium fuels, much effort has been expended to specify requirements, perform appropriate inspections, and to qualify experimental fuel plates and assemblies for irradiation. A great deal of consideration has been given to generate examinations and criteria that are both applicable to the unique fuel types being developed and consistent with industry practices for inspecting plate-type reactor fuel. Recent developments in quality assurance (QA) methodologies have given a heightened confidence in satisfactory fuel plate performance. At the same time, recommendations are given to further develop a system suitable for the testing and acceptance of production fuel elements containing low enriched uranium fuels. (author)

  16. Optimal testlet pool assembly for multistage testing designs

    NARCIS (Netherlands)

    Ariel, A.; Veldkamp, Bernard P.; Breithaupt, Krista

    2006-01-01

    Computerized multistage testing (MST) designs require sets of test questions (testlets) to be assembled to meet strict, often competing criteria. Rules that govern testlet assembly may dictate the number of questions on a particular subject or may describe desirable statistical properties for the

  17. 49 CFR 572.144 - Thorax assembly and test procedure.

    Science.gov (United States)

    2010-10-01

    ...-year-Old Child Crash Test Dummy, Alpha Version § 572.144 Thorax assembly and test procedure. (a) Thorax... displacement (compression) relative to the spine, measured with the chest deflection transducer (SA-572-S50...

  18. 49 CFR 572.164 - Thorax assembly and test procedure.

    Science.gov (United States)

    2010-10-01

    ... Hybrid III Six-Year-Old Weighted Child Test Dummy § 572.164 Thorax assembly and test procedure. (a... specified in 49 CFR 572.124(c): (1) The maximum sternum displacement relative to the spine, measured with...

  19. Maximum thermal loading test of BWR fuel assembly

    International Nuclear Information System (INIS)

    Nakajima, Yoshitaka; Yoshimura, Kunihiro; Nakamura, Satoshi; Ishizuka, Takao.

    1987-01-01

    Various proving tests on the reliability of nuclear power plants have been conducted at the Nuclear Power Engineering Test Center and at the Japan Power Plant Engineering and Inspection Corporation. The tests were initiated at the request of the Ministry of International Trade and Industry (MITI). Toshiba undertook one of the proving tests on the reliability of nuclear fuel assembly; the maximum thermal loading test of BWR fuel assembly from the Nuclear Power Engineering Test Center. These tests are part of the proving tests mentioned above, and their purpose is to confirm the reliability of the thermal hydraulic engineering techniques. Toshiba has been engaged for the past nine years in the design, fabrication and testing of the equipment. For the project, a test model fuel assembly was used to measure the critical power of the BWR fuel assembly and the void and fluidity of the coolant. From the test results, it has been confirmed that the heat is transferred safely from the fuel assembly to the coolant in the BWR nuclear power plant. In addition, the propriety and reliability of the thermal hydraulic engineering techniques for the fuel assembly have been proved. (author)

  20. FAITH - Fast Assembly Inhibitor Test for HIV

    Czech Academy of Sciences Publication Activity Database

    Hadravová, Romana; Rumlová, Michaela; Ruml, T.

    2015-01-01

    Roč. 486, Dec (2015), s. 78-87 ISSN 0042-6822 R&D Projects: GA ČR(CZ) GA14-15326S; GA MŠk LO1302; GA MŠk(CZ) LO1304 Institutional support: RVO:61388963 Keywords : retrovirus * HIV * assembly * assay * inhibitor Subject RIV: EE - Microbiology, Virology Impact factor: 3.200, year: 2015 http://www.sciencedirect.com/science/article/pii/S0042682215003864

  1. The development of flow test technology for PWR fuel assembly

    International Nuclear Information System (INIS)

    Chung, Moon Ki; Cha, Chong Hee; Chung, Chang Hwan; Chun, Se Young; Song, Chul Hwa; Chung, Heung Joon; Won, Soon Yeun; Cho, Yeong Rho; Kim, Bok Deuk

    1988-05-01

    KAERI has an extensive program to develope PWR fuel assembly. In relation to the program, development of flow test technology is needed to evaluate the thermal hydraulic compactibility and mechanical integrity of domestically fabricated nuclear fuels. A high-pressure and high-temperature flow test facility was designed to test domestically fabricated fuel assembly. The test section of the facility has capacity of a 6x6 full length PWR fuel assembly. A flow test rig was designed and installed at Cold Test Loop to carry out model experiments with 5x5 rod assembly under atmosphere pressure to get information about the characteristics of pressure loss of spacer grids and velocity distribution in the subchannels. LDV measuring technology was established using TSI's Laser Dopper Velocimeter 9100-3 System

  2. Subsystem software for TSTA [Tritium Systems Test Assembly

    International Nuclear Information System (INIS)

    Mann, L.W.; Claborn, G.W.; Nielson, C.W.

    1987-01-01

    The Subsystem Control Software at the Tritium System Test Assembly (TSTA) must control sophisticated chemical processes through the physical operation of valves, motor controllers, gas sampling devices, thermocouples, pressure transducers, and similar devices. Such control software has to be capable of passing stringent quality assurance (QA) criteria to provide for the safe handling of significant amounts of tritium on a routine basis. Since many of the chemical processes and physical components are experimental, the control software has to be flexible enough to allow for trial/error learning curve, but still protect the environment and personnel from exposure to unsafe levels of radiation. The software at TSTA is implemented in several levels as described in a preceding paper in these proceedings. This paper depends on information given in the preceding paper for understanding. The top level is the Subsystem Control level

  3. Integrated Quality Control of Precision Assemblies using Computed Tomography

    DEFF Research Database (Denmark)

    Stolfi, Alessandro

    coor-dinate measuring machines (CMMs) when working with complex and fragile parts. This Ph.D. project at DTU Mechanical Engineering concerns the applicability of CT for quality control of precision assem-blies. Investigations to quantify the accuracy of CT measurements, reference artefacts to correct...

  4. Quality engineering in FFTF irradiation tests

    International Nuclear Information System (INIS)

    Caplinger, W.H.

    1980-01-01

    The design and fabrication of an irradiation test for the Fast Flux Test Facility are planned, controlled and documented in accordance with the Department of Energy standards. Tests built by Westinghouse Hanford Company are further controlled and guided by a series of increasingly specific documents, including guidelines for program control, procedures for engineering operations, standard practices and detailed operating procedures. In response to this guidance, a series of five documents is prepared covering each step of the experiment from conception through fabrication and assembly. This paper describes the quality assurance accompanying these five steps

  5. Mechanical test for fuel assembly spacer grid

    International Nuclear Information System (INIS)

    Kang, Heung Seok; Jeong, Yeon Ho; Song, Kee Nam; Kim, Hyung Kyu; Yoon, Kyung Ho; Bang, Je Keun.

    1997-06-01

    In order to propose some tests for a new spacer grid, the grid mechanical tests performed by ABB-CE, KWU and Westinghouse have been investigated. It is known that a static compression test, a dynamic impact test, and a grid spring characteristic test were commonly carried out by the vendors when a prototype spacer grid was developed. The static compression test is to measure the stresses on the strips as well as to obtain the grid stiffness. The dynamic impact test is to get some basic data for accident analysis such as impact stiffness, impact strength, and coefficient of restitution. Since each fuel vendor has his theory on an accident analysis, every vendor employs his particular method for the dynamic impact test. The dynamic impact test can be divided into two in accordance with the number of impact face, and the duration of impact pulse. One is an one-sided impact test and the other is an through-gird impact test. The duration of the impact pulse for the former is considerably shorter than the latter. Therefore, the grid can endure much higher load under the one-sided impact condition than under the through-grid impact condition. The grid spring characteristic test is to obtain a force versus deflection curve. This curve is very important in designing the spacer grid to provide fuel rods with a sound supports in core. (author). 18 tabs., 26 figs

  6. Quality assurance in the procurement, design and manufacture of nuclear fuel assemblies

    International Nuclear Information System (INIS)

    1983-01-01

    This Safety Guide provides requirements and recommendations for quality assurance programmes that are relevant for the unique features of the procurement, design, manufacture, inspection, testing, packaging, shipping, storage, and receiving inspection of fuel assemblies for nuclear power plants. The generic quality assurance requirements of the Code and related Safety Guides are referred to where applicable, and are duplicated in this document where increased emphasis is desirable

  7. Assembly and installation of the large coil test facility test stand

    International Nuclear Information System (INIS)

    Queen, C.C. Jr.

    1983-01-01

    The Large Coil Test Facility (LCTF) was built to test six tokamak-type superconducting coils, with three to be designed and built by US industrial teams and three provided by Japan, Switzerland, and Euratom under an international agreement. The facility is designed to test these coils in an environment which simulates that of a tokamak. The heart of this facility is the test stand, which is made up of four major assemblies: the Gravity Base Assembly, the Bucking Post Assembly, the Torque Ring Assembly, and the Pulse Coil Assembly. This paper provides a detailed review of the assembly and installation of the test stand components and the handling and installation of the first coil into the test stand

  8. Results of assembly test of HTTR reactor internals

    International Nuclear Information System (INIS)

    Maruyama, S.; Saikusa, A.; Shiozawa, S.; Tsuji, N.; Miki, T.

    1996-01-01

    The assembly test of the HTTR actual reactor internals had been carried out at the works, prior to their installation in the actual reactor pressure vessel(RPV) at the construction site. The assembly test consists of several items such as examining fabricating precision of each component and alignment of piled-up structures, measuring circumferential coolant velocity profile in the passage between the simulated RPV and the reactor internals as well as under the support plates, measuring by-pass flow rate through gaps between the reactor internals, and measuring the binding force of the core restraint mechanism. Results of the test showed good performance of the HTTR reactor internals. Installation of the reactor internals in the actual RPV was started at the construction site of HTTR in April, 1995. In the installation process, main items of the assembly test at the works were repeated to investigate the reproducibility of installation. (author). 5 refs, 11 figs

  9. Tomographic imaging of severely disrupted fuel assemblies tested in TREAT

    International Nuclear Information System (INIS)

    Morman, J.A.; Froehle, P.H.; Holland, J.W.; Bennett, J.D.

    1990-01-01

    A series of CT codes is under development in the Reactor Analysis and Safety Division of Argonne National Laboratory for use as a post-test examination tool to analyze segments of the final fuel-bundle configuration of TREAT tests. This paper presents the results of CT analysis for fuel assemblies using neutron radiography. Fuel relocation following overpower transients in the TREAT reactor is examined for sections of the assemblies, and results are compared to metallographic sections. Further improvements are expected to increase the use and reliability of CT analysis as a standard post-test examination tool

  10. Performance of multihundred-watt fueled-sphere assemblies in the safety verification test

    International Nuclear Information System (INIS)

    Cramer, E.M.

    1975-09-01

    Seven fueled-sphere assemblies equivalent to those proposed for use in multihundred-watt thermoelectric generators were subjected to conditions that simulated the sequential environments produced by an orbital abort and earth impact. The procedures were similar to those in the Safety Sequential Test, and the assemblies differed only in minor dimensional and power level changes. All assemblies met the specifications for flight quality units. Visual examination indicated that all the iridium shells had lost their containment capability; however, rupturing of two shells was not confirmed. Five were obviously ruptured, and the fuel in three was exposed. All iridium fractures were essentially intergranular. A large grain size may have promoted this type of failure. Half of the vent assemblies failed to pass helium at ambient temperature after the test. Failure was because of nonmetallic materials in the vent frits. Release of plutonia per unit area of cracks in a containment shell ruptured by simulated earth impact was determined

  11. Test specification for decant pump and winch assembly. Revision 2

    International Nuclear Information System (INIS)

    Staehr, T.W.

    1995-01-01

    This specification provides the requirements for testing of the vertical turbine decant pump including the floating suction with load sensing winch control, instrumentation and the associated PLC/PC control system. All assembly necessary for testing including piping, temporary wiring, etc., shall be performed by the Seller. All referenced figures are at the back of this document. The testing consists of performance testing, winch testing and calibration, instrumentation verification testing and run-in testing of the pump. Testing shall be done in the presence and under the direction of the Buyer in accordance with this procedure

  12. Software quality testing process analysis

    OpenAIRE

    Mera Paz, Julián

    2016-01-01

    Introduction: This article is the result of reading, review, analysis of books, magazines and articles well known for their scientific and research quality, which have addressed the software quality testing process. The author, based on his work experience in software development companies, teaching and other areas, has compiled and selected information to argue and substantiate the importance of the software quality testing process. Methodology: the existing literature on the software qualit...

  13. Modal testing and identification of a PWR fuel assembly

    International Nuclear Information System (INIS)

    Pisapia, S.; Collard, B.; Mori, V.; Bellizzi, S.

    2003-01-01

    This study aims at characterizing the vibratory behavior of a full-scale fuel assembly using an experimental approach. The effect of the assembly environment (air, stagnant water, and water under flow) is studied. The analysis of the test series shows that the vibratory behavior of full-scale fuel assembly is strongly nonlinear. An identification phase, based on temporal mean square criterion, allows us to obtain a nonlinear model representative of the first vibration mode of a fuel assembly. The selected class of models including damping and stiffness nonlinear terms is efficient in air, in stagnant water, and in water under flow. In all environments, the stiffness decreases with the displacement level and the damping increases with the velocity level. In the presence of water, the damping goes up and increases again with flowrate. (author)

  14. Multiport riser and flange assemblies acceptance test report

    International Nuclear Information System (INIS)

    Precechtel, D.R.; Schroeder, B.K.

    1994-01-01

    This document presents the results of the acceptance test for the multiport riser (MPR) and multiport flange (MPF) assemblies. The accepted MPR and MPF assemblies will be used in support of the hydrogen mitigation project for double-shell waste tank 241-SY-101 and other related projects. The testing described in this document verifies that the mechanical and interface features are operating as designed and that the unit is ready for field service. The objectives of the acceptance testing were as follows: Basic equipment functions and mechanical interfaces were verified; Installation and removal of equipment were demonstrated to the degree possible; Operation of the decon spray system and all valving was confirmed; and the accumulated leak rate of the MPR and MPF assemblies was determined

  15. Verification Test of Automated Robotic Assembly of Space Truss Structures

    Science.gov (United States)

    Rhodes, Marvin D.; Will, Ralph W.; Quach, Cuong C.

    1995-01-01

    A multidisciplinary program has been conducted at the Langley Research Center to develop operational procedures for supervised autonomous assembly of truss structures suitable for large-aperture antennas. The hardware and operations required to assemble a 102-member tetrahedral truss and attach 12 hexagonal panels were developed and evaluated. A brute-force automation approach was used to develop baseline assembly hardware and software techniques. However, as the system matured and operations were proven, upgrades were incorporated and assessed against the baseline test results. These upgrades included the use of distributed microprocessors to control dedicated end-effector operations, machine vision guidance for strut installation, and the use of an expert system-based executive-control program. This paper summarizes the developmental phases of the program, the results of several assembly tests, and a series of proposed enhancements. No problems that would preclude automated in-space assembly or truss structures have been encountered. The test system was developed at a breadboard level and continued development at an enhanced level is warranted.

  16. Research on construction quality and improvement of assembly construction

    Science.gov (United States)

    Cheng, Fei

    2017-11-01

    Based on the acceleration of the urbanization process and the improvement of the quality of life of our residents, the demand for building construction has been increasing. In this context, the construction industry in order to promote the construction efficiency, quality improvement, to meet the needs of the development of the times to strengthen the new technology, the use of new technologies. At present, China’s engineering construction units in the process of carrying out the project to strengthen the use of assembly-type construction technology, which thus achieved for the traditional construction work low-level, high time-consuming issues, and promote the steady improvement of production efficiency. Based on this, this paper focuses on the analysis of the connotation of the assembly structure and analyzes the quality problems in the construction process of the construction projects and puts forward the improvement measures to promote the improvement of the building quality and the construction of the building Construction speed. Based on this, this paper analyzes the structural system and design of prefabricated building.

  17. PLC based control system for RAM assembly test facility

    International Nuclear Information System (INIS)

    Kulkarni, S.S.; Kumar, Vinaya; Chandra, Umesh

    1994-01-01

    The flexibility, expandability, ease of programming and diagnostic features makes the programmable logic controller (PLC) suitable for a variety of control applications in engineering system test facilities. A PLC based control system for RAM assembly test facility (RATF) and for testing the related hydraulic components is being developed and installed at BARC. This paper describes the approach taken for meeting the control requirements and illustrates the PLC software that has been developed. (author). 1 fig

  18. Methodology of thermalhydraulic tests of fuel assemblies for WWER-1000

    International Nuclear Information System (INIS)

    Archipov, A.; Kolochko, V.N.

    2001-01-01

    At present 11 units with WWER-1000 are in operation in Ukraine. The NPPs are provided with nuclear fuel from Russia. The fuel assemblies are fabricated and delivered to Ukrainian NPPs from Russia. However the contemporary tendencies of nuclear energy development in the world assume a diversification of nuclear fuel vendors. Therefore the creation of the own nuclear fuel cycle of Ukraine is in mind in the strategy of nuclear energy development of Ukraine. As a part of the fuel assemblies fabrication process complex of the thermalhydraulic tests should be carried out to confirm design characteristics of the fuel assemblies before they are loaded in the reactor facility. The experimental basis and scientific infrastructure for the thermalhydraulic tests arrangement and realization of the programs and procedures for the core equipment examination are under consideration. (author)

  19. PIE of test assembly of Qinshan nuclear power plant

    International Nuclear Information System (INIS)

    Ran, M.; Yan, J.; Wang, S.

    2000-01-01

    The small dimensional test fuel assembly (3x3-2) for the Qinshan Nuclear Power Plant was irradiated up to 25.7 Gwd/tU in the in-pile loop (15.5 Mpa,320 C) in Heavy Water Research Reactor (HWRR), CIAE, at simulative condition to Qinshan PWR normal and short time overpower operation for verifying the design, technology, and material properties of the fuel assembly. Comprehensive post-irradiation examination (PIE) including dimension measurement, gamma scanning, eddy current test, X ray, radiography, measurement of fission gas release, and quantitative metallography etc. were performed. PIE results show that the diameter of the fuel rods changed, ridges appeared on the cladding, pellets swelled, and the rate of fission gas release was higher than what we expected. The results would be an important basis for further improvement of design, technology and material properties for Qinshan PWR assembly. (author)

  20. Development of training simulator based on critical assemblies test bench

    International Nuclear Information System (INIS)

    Narozhnyi, A.T.; Vorontsov, S.V.; Golubeva, O.A.; Dyudyaev, A.M.; Il'in, V.I.; Kuvshinov, M.I.; Panin, A.V.; Peshekhonov, D.P.

    2007-01-01

    When preparing critical mass experiment, multiplying system (MS) parts are assembled manually. This work is connected with maximum professional risk to personnel. Personnel training and keeping the skill of working experts is the important factor of nuclear safety maintenance. For this purpose authors develop a training simulator based on functioning critical assemblies test bench (CATB), allowing simulation of the MS assemblage using training mockups made of inert materials. The control program traces the current status of MS under simulation. A change in the assembly neutron physical parameters is mapped in readings of the regular devices. The simulator information support is provided by the computer database on physical characteristics of typical MS components The work in the training mode ensures complete simulation of real MS assemblage on the critical test bench. It makes it possible to elaborate the procedures related to CATB operation in a standard mode safely and effectively and simulate possible abnormal situations. (author)

  1. Subsystem cost data for the tritium systems test assembly

    International Nuclear Information System (INIS)

    Bartlit, J.R.; Anderson, J.L.; Rexroth, V.G.

    1983-01-01

    Details of subsystem costs are among the questions most frequently asked about the $14.4 million Tritium Systems Test Assembly (TSTA) at Los Alamos National Laboratory. This paper presents a breakdown of cost components for each of the 20 major subsystems of TSTA. Also included are details to aid in adjusting the costs to other years, contracting conditions, or system sizes

  2. Operating experience and procedures at the tritium systems test assembly

    International Nuclear Information System (INIS)

    Carlson, R.V.; Binning, K.E.; Cole, S.P.; Jenkins, E.M.; Wilhelm, R.C.; Cole, S.P.

    1988-01-01

    Operating procedures are important for the safe and efficient operation of the Tritium Systems Test Assembly (TSTA). TSTA has been operating for four years with tritium in a safe and efficient manner. The inventory of tritium in the process loop is 100 grams and several milestone runs have been completed. This paper describes the methods used to operate TSTA. 3 refs., 1 fig

  3. Tensile testing grips are easily assembled under liquid nitrogen

    Science.gov (United States)

    Skalka, R. J.; Vandergrift, E. F.

    1967-01-01

    Split-screw grips for tensile testing provide uniform loading on the specimen shoulders. Holes in the heads enable the screws and specimen to be threaded as an assembly into a grip body, closely controlled guides and seats afford positive seating, and precision machining of mating surfaces minimizes misalignment effects.

  4. 49 CFR 572.142 - Head assembly and test procedure.

    Science.gov (United States)

    2010-10-01

    ... acceleration versus time history curve shall be unimodal, and the oscillations occurring after the main pulse... for testing. (3) Suspend the head assembly with its midsagittal plane in vertical orientation as shown... head in transverse alignment with the CG, shall be used to ensure that the head transverse plane is...

  5. Indoor Air Quality Test House

    Data.gov (United States)

    Federal Laboratory Consortium — Description:In order to enable studies of a range of indoor air quality and ventilation issues, EL maintains a highly instrumented three-bedroom test house. Previous...

  6. Quality control of FWC during assembly and commissioning in SST-1 Tokamak

    Science.gov (United States)

    Patel, Hitesh; Santra, Prosenjit; Parekh, Tejas; Biswas, Prabal; Jayswal, Snehal; Chauhan, Pradeep; Paravastu, Yuvakiran; George, Siju; Semwal, Pratibha; Thankey, Prashant; Ramesh, Gattu; Prakash, Arun; Dhanani, Kalpesh; Raval, D. C.; Khan, Ziauddin; Pradhan, Subrata

    2017-04-01

    First Wall Components (FWC) of SST-1 tokamak, which are in the immediate vicinity of plasma, comprises of limiters, divertors, baffles, passive stabilizers designed to operate long duration (∼1000 s) discharges of elongated plasma. All FWC consist of copper alloy heat sink modules with SS cooling tubes brazed onto it, graphite tiles acting as armour material facing the plasma, and are mounted to the vacuum vessels with suitable Inconel support structures at inter-connected ring & port locations. The FWC are very recently assembled and commissioned successfully inside the vacuum vessel of SST-1 undergoing a rigorous quality control and checks at every stage of the assembly process. This paper will present the quality control aspects and checks of FWC from commencement of assembly procedure, namely material test reports, leak testing of high temperature baked components, assembled dimensional tolerances, leak testing of all welded joints, graphite tile tightening torques, electrical continuity and electrical isolation of passive stabilizers from vacuum vessel, baking and cooling hydraulic connections inside vacuum vessel.

  7. Quality control of FWC during assembly/commissioning on SST-1

    International Nuclear Information System (INIS)

    Patel, Hiteshkumar; Santra, Prosenjit; Jaiswal, Snehal

    2015-01-01

    First Wall components (FWC) of SST-1 tokamak, which are in the immediate vicinity of plasma comprises of limiters, divertors, baffles, passive stabilizers are designed to operate long duration (1000 s) discharges of elongated plasma. All FWC consists of a copper alloy heat sink modules with SS cooling tubes brazed onto it, graphite tiles acting as armour material facing the plasma, and are mounted to the vacuum vessels with suitable Inconel support structures at ring and port locations. The FWC are very recently assembled and commissioned successfully inside the vacuum vessel of SST-1 under going a rigorous quality control and checks at every stage of the assembly process. This paper will present the quality control and checks of FWC from commencement of assembly procedure, namely material test reports, leak testing of high temperature baked components, assembled dimensional tolerances, leak testing of all welded joints, graphite tile tightening torques, electrical continuity of passive stabilizers, and electrical isolation of passive stabilizers from vacuum vessel, baking and cooling hydraulic connections inside vacuum vessel. (author)

  8. Decant pump assembly and controls qualification testing - test report

    Energy Technology Data Exchange (ETDEWEB)

    Staehr, T.W., Westinghouse Hanford

    1996-05-02

    This report summarizes the results of the qualification testing of the supernate decant pump and controls system to be used for in-tank sludge washing in aging waste tank AZ-101. The test was successful and all components are qualified for installation and use in the tank.

  9. Quality assurance on the welding work during the assembly of Wendelstein 7-X

    International Nuclear Information System (INIS)

    Schroeder, Michael

    2011-01-01

    At the Max-Planck-Institut fuer Plasmaphysik (IPP) in Greifswald (Germany) the stellarator experiment W7-X is presently being assembled. During this assembly many different weld connections are made, which are very important for the proper functionality of the experiment. This concerns mainly the structural integrity and the leak tightness. The quality requirements for the weld seams are high (mainly class B according to DIN EN ISO 5817), because the complex machine must operate reliably for more than 15 years and the possibility of any repair or change of important components is very small. To guarantee a high quality of the welds they are submitted to different tests. The applied test methods are depending on the function of the weld, the wall thickness, the seam geometry, and the material. The main test methods are visual testing (VT), penetrant testing (PT), radiographic testing (RT), ultrasonic testing (UT), leak testing (LT), permeability testing and macros. The paper will describe the application of these test methods and show their need by examples of typical weld imperfections.

  10. BWR 9 X 9 Fuel Assembly Thermal-Hydraulic Tests (2): Hydraulic Vibration Test

    International Nuclear Information System (INIS)

    Yoshiaki Tsukuda; Katsuichiro Kamimura; Toshiitsu Hattori; Akira Tanabe; Noboru Saito; Masahiko Warashina; Yuji Nishino

    2002-01-01

    Nuclear Power Engineering Corporation (NUPEC) conducted thermal-hydraulic projects for verification of thermal-hydraulic design reliability for BWR high-burnup 8 x 8 and 9 x 9 fuel assemblies, entrusted by the Ministry of Economy, Trade and Industry (METI). As a part of the NUPEC thermal-hydraulic projects, hydraulic vibration tests using full-scale test assemblies simulating 9 x 9 fuel assemblies were carried out to evaluate BWR fuel integrity. The test data were applied to development of a new correlation for the estimation of fuel rod vibration amplitude. (authors)

  11. Reliability Testing the Die-Attach of CPV Cell Assemblies

    Energy Technology Data Exchange (ETDEWEB)

    Bosco, N.; Sweet, C.; Kurtz, S.

    2011-02-01

    Results and progress are reported for a course of work to establish an efficient reliability test for the die-attach of CPV cell assemblies. Test vehicle design consists of a ~1 cm2 multijunction cell attached to a substrate via several processes. A thermal cycling sequence is developed in a test-to-failure protocol. Methods of detecting a failed or failing joint are prerequisite for this work; therefore both in-situ and non-destructive methods, including infrared imaging techniques, are being explored as a method to quickly detect non-ideal or failing bonds.

  12. The Assembly and Test of Pressure Vessel for Irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Park, Kook Nam; Lee, Jong Min; Youn, Young Jung; June, Hyung Kil; Ahn, Sung Ho; Lee, Kee Hong; Kim, Young Ki [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Kennedy, Timothy C. [Oregon State University, Corvallis (United States)

    2009-02-15

    The Fuel Test Loop(FTL) which is capable of an irradiation testing under a similar operating condition to those of PWR(Pressurized Water Reactor) and CANDU(CANadian Deuterium Uranium reactor) nuclear power plants has been developed and installed in HANARO, KAERI(Korea Atomic Energy Research Institute). It consists of In-Pile Section(IPS) and Out-of Pile System(OPS). The IPS, which is located inside the pool is divided into 3-parts: the in-pool pipes, the IVA(IPS Vessel Assembly) and the support structures. The test fuel is loaded inside a double wall, inner pressure vessel and outer pressure vessel, to keep the functionality of the reactor coolant pressure boundary. The IVA is manufactured by local company and the functional test and verification were done through pressure drop, vibration, hydraulic and leakage tests. The brazing technique for the instrument lines has been checked for its functionality and performance. An IVA has been manufactured by local technique and have finally tested under high temperature and high pressure. The IVA and piping did not experience leakage, as we have checked the piping, flanges, assembly parts. We have obtained good data during the three cycle test which includes a pressure test, pressure and temperature cycling, and constant temperature.

  13. The Assembly and Test of Pressure Vessel for Irradiation

    International Nuclear Information System (INIS)

    Park, Kook Nam; Lee, Jong Min; Youn, Young Jung; June, Hyung Kil; Ahn, Sung Ho; Lee, Kee Hong; Kim, Young Ki; Kennedy, Timothy C.

    2009-01-01

    The Fuel Test Loop(FTL) which is capable of an irradiation testing under a similar operating condition to those of PWR(Pressurized Water Reactor) and CANDU(CANadian Deuterium Uranium reactor) nuclear power plants has been developed and installed in HANARO, KAERI(Korea Atomic Energy Research Institute). It consists of In-Pile Section(IPS) and Out-of Pile System(OPS). The IPS, which is located inside the pool is divided into 3-parts: the in-pool pipes, the IVA(IPS Vessel Assembly) and the support structures. The test fuel is loaded inside a double wall, inner pressure vessel and outer pressure vessel, to keep the functionality of the reactor coolant pressure boundary. The IVA is manufactured by local company and the functional test and verification were done through pressure drop, vibration, hydraulic and leakage tests. The brazing technique for the instrument lines has been checked for its functionality and performance. An IVA has been manufactured by local technique and have finally tested under high temperature and high pressure. The IVA and piping did not experience leakage, as we have checked the piping, flanges, assembly parts. We have obtained good data during the three cycle test which includes a pressure test, pressure and temperature cycling, and constant temperature

  14. Subcooler assembly for SSC single magnet test program

    International Nuclear Information System (INIS)

    Wu, K.C.; Brown, D.P.; Sondericker, J.H.; Farah, Y.; Zantopp, D.; Nicoletti, A.

    1991-01-01

    A subcooler assembly has been designed, constructed and installed in the MAGCOOL magnet test area at Brookhaven National Laboratory. Since July 1989, it has been used for testing SSC magnets. This subcooler assembly and cryogenic system are the first of its kind ever built. Today, with more than 5000 hours of operating time, the subcooler has proved to be a reliable unit with individual components meeting design expectations. The lowest temperatures achieved with one SSC dipole are 3.0 K at the suction of the cold vacuum pump and 3.2 K at the return of the magnet. The system performs well in both steady state operation and during magnet quench, subcooling, cooldown and warmup. 4 refs., 7 figs

  15. The Tritium Systems Test Assembly applicability to ITER

    International Nuclear Information System (INIS)

    Anderson, J.L.

    1988-01-01

    The Tritium Systems Test Assembly (TSTA), is operated by the Los Alamos National Laboratory (LANL) under the sponsorship of the US Department of Energy (DOE) and the Japan Atomic Energy Research Institute (JAERI). The objectives of the TSTA project are to develop, demonstrate, and evaluate the exhaust gas processing and tritium related safety systems for the magnetic fusion energy program. The applicability of these processes for the ITER Tokamak is discussed

  16. Current operations and experiments at the Tritium Systems Test Assembly

    International Nuclear Information System (INIS)

    Bartlit, J.R.; Anderson, J.L.

    1985-01-01

    The Tritium Systems Test Assembly (TSTA) has continued to move toward operation of a fully-integrated, full-sized, computer-controlled fusion fuel processing loop. Concurrent, nonloop experiments have answered important questions on new components and issues such as palladium diffusion membranes, ceramic electrolysis cells, regenerable tritium getters, laser Raman spectroscopy, unregenerable tritium inventory on molecular sieves, tritium contamination problems and decontamination methods, and operating data on reliability, emissions, doses, and wastes generated. 4 refs., 2 figs

  17. An Interactive Method to Solve Infeasibility in Linear Programming Test Assembling Models

    Science.gov (United States)

    Huitzing, Hiddo A.

    2004-01-01

    In optimal assembly of tests from item banks, linear programming (LP) models have proved to be very useful. Assembly by hand has become nearly impossible, but these LP techniques are able to find the best solutions, given the demands and needs of the test to be assembled and the specifics of the item bank from which it is assembled. However,…

  18. Tower Shielding Reactor II design and operation report. Vol. 3. Assembling and testing of the control mechanism assembly

    International Nuclear Information System (INIS)

    Ward, D.R.; Holland, L.B.

    1979-09-01

    The mechanisms that are operated to control the reactivity of the Tower Shielding Reactor II(TSR-II) are mounted on a Control Mechanism Housing (CMH) that is centered inside the reactor core. The information required to procure, fabricate, inspect, and assemble a CMH is contained in the ORNL engineering drawings listed in the appropriate sections. The components are fabricated and inspected from these drawings in accordance with a Quality Assurance Plan and a Manufacturing Plan. The material in this report describes the acceptance and performance tests of CMH subassemblies used ty the Tower Shielding Facility (TSF) staff but it can also be used by personnel fabricating the components. This information which was developed and used before the advent of the formalized QA Program and Manufacturing Plans evolved during the fabrication and testing of the first five CMHs

  19. Development of tritium technology at the Tritium Systems Test Assembly

    International Nuclear Information System (INIS)

    Anderson, J.L.; Bartlit, J.R.

    1982-01-01

    The Tritium Systems Test Assembly (TSTA) at the Los Alamos National Laboratory is dedicated to the development, demonstration, and interfacing of technologies related to the deuterium-tritium fuel cycle for large scale fusion reactor systems starting with the Fusion Engineering Device (FED) or the International Tokamak Reactor (INTOR). This paper briefly describes the fuel cycle and safety systems at TSTA including the Vacuum Facility, Fuel Cleanup, Isotope Separation, Transfer Pumping, Emergency Tritium Cleanup, Tritium Waste Treatment, Tritium Monitoring, Data Acquisition and Control, Emergency Power and Gas Analysis systems. Discussed in further detail is the experimental program proposed for the startup and testing of these systems

  20. Quality of dry chemistry testing.

    Science.gov (United States)

    Nakamura, H; Tatsumi, N

    1999-01-01

    Since the development of the qualitative test paper for urine in 1950s, several kinds of dry-state-reagents and their automated analyzers have been developed. "Dry chemistry" has become to be called since the report on the development of quantitative test paper for serum bilirubin with reflectometer in the end of 1960s and dry chemistry has been world widely known since the presentation on the development of multilayer film reagent for serum biochemical analytes by Eastman Kodak Co at the 10th IFCC Meeting in the end of 1970s. We have reported test menu, results in external quality assessment, merits and demerits, and the future possibilities of dry chemistry.

  1. Vibration test and endurance test for HANARO 36-element fuel assembly

    International Nuclear Information System (INIS)

    Ryu, Jeong Soo; Kim, Heon ll; Chung, Heung June

    1998-06-01

    Vibration test and endurance test for HANARO DU (depleted uranium) 36-element fuel assembly which was fabricated by KAERI were carried out based on the HANARO operation conditions. The endurance test of 22 days was added to the previous 18 days test. The vibration test was performed at various flow rates. Vibration frequency for the 36-element fuel assembly is between 11 to 14.5 Hz. And the maximum vibration displacement is less than 100 μm. From the endurance test result, it can be concluded that the appreciable fretting wear for the 36-element fuel assembly and the hexagonal flow tube was not observed. (author). 4 refs., 5 tabs., 29 figs

  2. DKIST enclosure modeling and verification during factory assembly and testing

    Science.gov (United States)

    Larrakoetxea, Ibon; McBride, William; Marshall, Heather K.; Murga, Gaizka

    2014-08-01

    The Daniel K. Inouye Solar Telescope (DKIST, formerly the Advanced Technology Solar Telescope, ATST) is unique as, apart from protecting the telescope and its instrumentation from the weather, it holds the entrance aperture stop and is required to position it with millimeter-level accuracy. The compliance of the Enclosure design with the requirements, as of Final Design Review in January 2012, was supported by mathematical models and other analyses which included structural and mechanical analyses (FEA), control models, ventilation analysis (CFD), thermal models, reliability analysis, etc. During the Enclosure Factory Assembly and Testing the compliance with the requirements has been verified using the real hardware and the models created during the design phase have been revisited. The tests performed during shutter mechanism subsystem (crawler test stand) functional and endurance testing (completed summer 2013) and two comprehensive system-level factory acceptance testing campaigns (FAT#1 in December 2013 and FAT#2 in March 2014) included functional and performance tests on all mechanisms, off-normal mode tests, mechanism wobble tests, creation of the Enclosure pointing map, control system tests, and vibration tests. The comparison of the assumptions used during the design phase with the properties measured during the test campaign provides an interesting reference for future projects.

  3. The Assembly of the LHC Short Straight Sections at CERN Work Organization, Quality Assurance and Lessons Learned

    CERN Document Server

    Bourcey, N; López, R; Poncet, A; Parma, V

    2007-01-01

    After 4 years of activity, the assembly of approximately 500 Short Straight Sections (SSS) for the LHC has come to an end at the beginning of 2007. This activity, which was initially foreseen in European industry, was in-sourced at CERN because of the insolvency of the prime contractor. While the quadrupole cold masses were produced in industry, the assembly within their cryostats was transferred to CERN and executed by an external company under a result-oriented contract. CERN procured cryostat components, set up a dedicated 2000 m2 assembly hall with all the specific assembly equipment and tooling and defined the assembly and testing procedures. The contractor took up responsibility for the delivery, on time, of assemblies according to the required quality. A dedicated CERN production and quality assurance team was constituted. A specific quality assurance plan was set up involving 2 additional contractors responsible for weld inspections on a total of about 20'000 assembly welds and the execution of about ...

  4. Design of a high-flux test assembly for the Fusion Materials Irradiation Test Facility

    International Nuclear Information System (INIS)

    Opperman, E.K.; Vogel, M.A.

    1982-01-01

    The Fusion Material Test Facility (FMIT) will provide a high flux fusion-like neutron environment in which a variety of structural and non-structural materials irradiations can be conducted. The FMIT experiments, called test assemblies, that are subjected to the highest neutron flux magnitudes and associated heating rates will require forced convection liquid metal cooling systems to remove the neutron deposited power and maintain test specimens at uniform temperatures. A brief description of the FMIT facility and experimental areas is given with emphasis on the design, capabilities and handling of the high flux test assembly

  5. Software design for the Tritium System Test Assembly

    International Nuclear Information System (INIS)

    Claborn, G.W.; Heaphy, R.T.; Lewis, P.S.; Mann, L.W.; Nielson, C.W.

    1983-01-01

    The control system for the Tritium Systems Test Assembly (TSTA) must execute complicated algorithms for the control of several sophisticated subsystems. It must implement this control with requirements for easy modifiability, for high availability, and provide stringent protection for personnel and the environment. Software techniques used to deal with these requirements are described, including modularization based on the structure of the physical systems, a two-level hierarchy of concurrency, a dynamically modifiable man-machine interface, and a specification and documentation language based on a computerized form of structured flowcharts

  6. Manufacture, testing and assembly preparation of the JET vacuum vessel

    International Nuclear Information System (INIS)

    Arbez, J.; Baeumel, S.; Dean, J.R.; Duesling, G.; Froger, C.; Hemmerich, J.L.; Walravens, M.; Walter, K.; Winkel, T.

    1983-01-01

    To reach the target pressure of 10 -9 mbar, JET's double-walled Inconel vacuum vessel is being manufactured and assembled in clean conditions and with meticulous leak detection. Each octant (1/8 of the torus) is baked in an oven to 520 0 C and leak tested at 350 0 C to reveal leaks as small as 10 -9 mbar l/s, which are repaired. In service the vessel will be baked periodically to 500 0 C by CO 2 passing between its walls. The single-walled ports will be electrically heated. (author)

  7. Tritium system test assembly control system cost estimate

    International Nuclear Information System (INIS)

    Stutz, R.A.

    1979-01-01

    The principal objectives of the Tritium Systems Test Assembly (TSTA), which includes the development, demonstration and interfacing of technologies related to the deuterium--tritium fuel cycle for fusion reactor systems, are concisely stated. The various integrated subsystems comprising TSTA and their functions are discussed. Each of the four major subdivisions of TSTA, including the main process system, the environmental and safety systems, supporting systems and the physical plant are briefly discussed. An overview of the Master Data Acquisition and Control System, which will control all functional operation of TSTA, is provided

  8. Software design for the Tritium Systems Test Assembly

    International Nuclear Information System (INIS)

    Claborn, G.W.; Keaphy, R.T.

    1983-01-01

    The control system for the Tritium Systems Test Assembly (TSTA) must execute complicated algorithms for the control of several sophisticated subsystems. It must implement this control with requirements for easy modifiability, for high availability, and provide stringent protection for personnel and the environment. Software techniques used to deal with these requirements are described, including modularization based on the structure of the physical systems, a two-level hierarchy of concurrency, a dynamically modifiable manmachine interface, and a specification and documentation language based on a computerized form of structured flowcharts

  9. Installation Test of Cold Neutron Soruce In-pool Assembly

    International Nuclear Information System (INIS)

    Lee, Kye Hong; Choi, J.; Wu, S. I.; Kim, Y. K.; Cho, Y. G.; Lee, C. H.; Kim, K. R.

    2006-04-01

    Before installation of the final cold neutron source in-pool assembly (IPA) in the vertical CN hole at the HANARO, the research reactor, the installation test of IPA has been conducted in the CN hole of the reactor using a full-scaled mock-up in-pool assembly. The well-known cold neutron sources, being safely operated or being now constructed, had been constructed together with each research reactor; therefore, there was little limitation to obtain the optimal cold neutron source since a cold neutron source had been decided to be installed in the reactor from the beginning of the design for the reactor construction. Unlikely, the HANARO has been operated for 10 years so that we have got lots of design limitation in terms of the decisions in the optimal shape, size, minimal light-water gap, and adhesion degree to the CN beam tube, IPA installation tools, etc. for the construction of the CNS. Accordingly, the main objective of this test is to understand any potential problem or interference happened inside the reactor by installing the mock-up IPA and installation bracket. The outcomes from this test is reflected on the finalizing process of the IPA detail design

  10. Kodak Mirror Assembly Tested at Marshall Space Flight Center

    Science.gov (United States)

    2003-01-01

    This photo (a frontal view) is of one of many segments of the Eastman-Kodak mirror assembly being tested for the James Webb Space Telescope (JWST) project at the X-Ray Calibration Facility at Marshall Space Flight Center (MSFC). MSFC is supporting Goddard Space Flight Center (GSFC) in developing the JWST by taking numerous measurements to predict its future performance. The tests are conducted in a vacuum chamber cooled to approximate the super cold temperatures found in space. During its 27 years of operation, the facility has performed testing in support of a wide array of projects, including the Hubble Space Telescope (HST), Solar A, Chandra technology development, Chandra High Resolution Mirror Assembly and science instruments, Constellation X-Ray Mission, and Solar X-Ray Imager, currently operating on a Geostationary Operational Environment Satellite. The JWST is NASA's next generation space telescope, a successor to the Hubble Space Telescope, named in honor of NASA's second administrator, James E. Webb. It is scheduled for launch in 2010 aboard an expendable launch vehicle. It will take about 3 months for the spacecraft to reach its destination, an orbit of 940,000 miles in space.

  11. Pixel Detector Trial Assembly Test in the SR1 building

    CERN Multimedia

    D. Giugni

    2004-01-01

    During the last two months the Pixel group [LBL, Milan and Wuppertal] made a successful integration test on the mechanics of the barrel. The scope of the test was to qualify the integration procedures and the various assembling tools. The test took place in the clean room of the SR1 building at CERN, where the detector has been assembled around a dummy beam pipe made of Stainless Steel. The process is rather complex: the shells come in two parts and they have to be clamped together to get the full shell. This operation is carried out by a dedicated tool which is shown to the right in the picture below. The layer 1 shell is clamped around a "service" pipe that will be used for moving the full layer to the integration tool [ITT] which is visible on the left. View of the tools devoted to the Pixel barrel integration in the SR1 building Also visible in the picture is the global frame that is actually held by the tool. It will engage the layers sliding onto the rails. The first two layers are sequentially...

  12. Tritium Systems Test Assembly: design for major device fabrication review

    International Nuclear Information System (INIS)

    Anderson, J.L.; Sherman, R.H.

    1977-06-01

    This document has been prepared for the Major Device Fabrication Review for the Tritium Systems Test Assembly (TSTA). The TSTA is dedicated to the development, demonstration, and interfacing of technologies related to the deuterium-tritium fuel cycle for fusion reactor systems. The principal objectives for TSTA are: (a) demonstrate the fuel cycle for fusion reactor systems; (b) develop test and qualify equipment for tritium service in the fusion program; (c) develop and test environmental and personnel protective systems; (d) evaluate long-term reliability of components; (e) demonstrate long-term safe handling of tritium with no major releases or incidents; and (f) investigate and evaluate the response of the fuel cycle and environmental packages to normal, off-normal, and emergency situations. This document presents the current status of a conceptual design and cost estimate for TSTA. The total cost to design, construct, and operate TSTA through FY-1981 is estimated to be approximately $12.2 M

  13. Open test assembly (OTA) shear demonstration testing work/test plan

    International Nuclear Information System (INIS)

    Hiller, S.W.

    1998-01-01

    This document describes the development testing phase associated with the OTA Shear activity and defines the controls to be in place throughout the testing. The purpose of the OTA Shear Program was to provide equipment that is needed for the processing of 40 foot long, sodium wetted, irradiated core components previously used in the FFTF reactor to monitor fuel and materials tests. There are currently 15 of these OTA test stalks located in the Test Assembly Conditioning Station (TACS) inerted vault. These need to be dispositioned for a shutdown mission to eliminate this highly activated, high dose inventory prior to turnover to the ERC since they must be handled by remote operations. These would also need to be dispositioned for a restart mission to free up the vault they currently reside in. The waste handling and cleaning equipment in the J33M Cell was designed and built for the handling of reactor components up to the standard 12 foot length. This program will provide the equipment to the IEM Cell to remotely section the OTAS into pieces less than 12 feet in length to allow for the necessary handling and cleaning operations required for proper disposition. Due to the complexity of all operations associated with remote handling, the availability of the IEM Cell training facility, and the major difficulty with reworking contaminated equipment, it was determined that preliminary testing of the equipment was desirable, This testing activity would provide the added assurance that the equipment will operate as designed prior to performance of the formal Acceptance Test Procedure (ATP) at the IEM Cell, This testing activity will also allow for some operator familiarity and procedure checkout prior to actual installation into the IEM Cell. This development testing will therefore be performed at the conclusion of equipment fabrication and prior to transfer of the equipment to the 400 Area

  14. Support of Construction and Verification of Out-of-Pile Fuel Assembly Test Facilities

    Energy Technology Data Exchange (ETDEWEB)

    Park, Nam Gyu; Kim, K. T.; Park, J. K. [KNF, Daejeon (Korea, Republic of)] (and others)

    2006-12-15

    Fuel assembly and components should be verified by the out-of-pile test facilities in order to load the developed fuel in reactor. Even though most of the component-wise tests have been performed using the facilities in land, the assembly-wise tests has been depended on the oversees' facility due to the lack of the facilities. KAERI started to construct the assembly-wise mechanical/hydraulic test facilities and KNF, as an end user, is supporting the mechanical/hydraulic test facility construction by using the technologies studied through the fuel development programs. The works performed are as follows: - Test assembly shipping container design and manufacturing support - Fuel handling tool design : Gripper, Upper and lower core simulators for assembly mechanical test facility, Internals for assembly hydraulic test facility - Manufacture of test specimens : skeleton and assembly for preliminary functional verification of assembly mechanical/hydraulic test facilities, two assemblies for the verification of assembly mechanical/hydraulic test facilities, Instrumented rod design and integrity evaluation - Verification of assembly mechanical/hydraulic test facilities : test data evaluation.

  15. Support of Construction and Verification of Out-of-Pile Fuel Assembly Test Facilities

    International Nuclear Information System (INIS)

    Park, Nam Gyu; Kim, K. T.; Park, J. K.

    2006-12-01

    Fuel assembly and components should be verified by the out-of-pile test facilities in order to load the developed fuel in reactor. Even though most of the component-wise tests have been performed using the facilities in land, the assembly-wise tests has been depended on the oversees' facility due to the lack of the facilities. KAERI started to construct the assembly-wise mechanical/hydraulic test facilities and KNF, as an end user, is supporting the mechanical/hydraulic test facility construction by using the technologies studied through the fuel development programs. The works performed are as follows: - Test assembly shipping container design and manufacturing support - Fuel handling tool design : Gripper, Upper and lower core simulators for assembly mechanical test facility, Internals for assembly hydraulic test facility - Manufacture of test specimens : skeleton and assembly for preliminary functional verification of assembly mechanical/hydraulic test facilities, two assemblies for the verification of assembly mechanical/hydraulic test facilities, Instrumented rod design and integrity evaluation - Verification of assembly mechanical/hydraulic test facilities : test data evaluation

  16. [Design of coal stove, construction, assembly and test

    International Nuclear Information System (INIS)

    Bitrus, K.D.; Dauda, S.

    2004-01-01

    Some years back, after the discovery of Petroleum, Kerosene as one of the fraction of the distillation of Petroleum came into use as cooking fuel and a reduction in pressure was seen on wood and vegetation. Along this line, by the improvement of sciences and technology gas cooker and electric cooker were developed; but epileptic supply of electricity, gas and government policy on deforestation showed that continuous dependence on wood, electricity, gas and kerosene as the only sources of cooking fuel is not going to solve Nigeria domestic cooking problem. To solve this, coal as a source of heat energy could be used as a cooking fuel. However, this paper reports the design of coal stove, construction, assembly and test. The test result showed that using coal (anthracite) as the fuel on a pot of 200g containing 800g of water at room temperature could boil the water in 20 minutes

  17. Development and applications of a computer-aided phased array assembly for ultrasonic testing

    International Nuclear Information System (INIS)

    Schenk, G.; Montag, H.J.; Wuestenberg, H.; Erhard, A.

    1985-01-01

    The use of modern electronic equipment for programmable signal delay increasingly allows transit-time controlled phased arrays to be applied in non-destructive, ultrasonic materials testing. A phased-array assembly is described permitting fast variation of incident angle of acoustic wave and of sonic beam focus, together with numerical evaluation of measured data. Phased arrays can be optimized by adding programmable electronic equipment so that the quality of conventional designs can be achieved. Applications of the new technical improvement are explained, referring to stress corrosion cracking, turbine testing, echo tomography of welded joints. (orig./HP) [de

  18. 49 CFR 572.75 - Lumbar spine, abdomen, and pelvis assembly and test procedure.

    Science.gov (United States)

    2010-10-01

    ...) ANTHROPOMORPHIC TEST DEVICES 6-Year-Old Child § 572.75 Lumbar spine, abdomen, and pelvis assembly and test procedure. (a) Lumbar spine, abdomen, and pelvis assembly. The lumbar spine, abdomen, and pelvis consist of... 49 Transportation 7 2010-10-01 2010-10-01 false Lumbar spine, abdomen, and pelvis assembly and...

  19. Nondestructive test for assembly relationship of initiating explosive device

    International Nuclear Information System (INIS)

    Wang Xiangang; Zhang Chaozong; Guo Zhiping

    2009-01-01

    A 3D computed tomography (CT) method to inspect assembly relationship of initiating explosive device and to nondestructively evaluate assembly relationship by building geometric model from CT images was described. The experiment result proves that this method accurately inspects assembly relationship of initiating explosive device. (authors)

  20. The tritium systems test assembly: Overview and recent results

    International Nuclear Information System (INIS)

    Bartlit, J.R.; Anderson, J.L.

    1988-01-01

    The fusion technology development program for tritium in the US is centered around the Tritium Systems Test Assembly (TSTA) at Los Alamos National Laboratory. The TSTA is a full-scale system of reactor exhaust gas reprocessing for an ITER-sized machine. That is, TSTA has the capacity to process tritium in a closed loop mode at the rate of 1 kg per day, requiring a tritium inventory of about 100 g. The TSTA program also interacts with all other tritium-related fusion technology programs in the US and all major programs abroad. This report summarizes the current status, results and interactions of the TSTA. Special emphasis is given to operations in May/June using large compound cryopumps that completed the fuel loop integration of all TSTA subsystems for the first time. 6 refs., 2 figs

  1. Tritium contaminated waste management at the tritium systems test assembly

    International Nuclear Information System (INIS)

    Jalbert, R.A.; Carlson, R.V.

    1987-01-01

    The Tritium Systems Test Assembly (TSTA) at Los Alamos continues to move toward full operation of an integrated, full-sized, computer-controlled fusion fuel processing loop. Concurrent nonloop experiments further the development of advanced tritium technologies and handling methods. Since tritium operations began in June 1984, tritium contaminated wastes have been produced at TSTA that are roughly typical in kind and amount of those to be produced by tritium fueling operations at fusion reactors. Methods of managing these wastes are described, including information on some methods of decontamination so that equipment can be reused. Data are given on the kinds and amounts of wastes and the general level of contamination. Also included are data on environmental emissions and doses to personnel that have resulted from TSTA operations. Particular problems in waste managements are discussed

  2. Report of lower endplug welding, and testing and inspecting result for MONJU 1{sup th} reload core fuel assembly

    Energy Technology Data Exchange (ETDEWEB)

    Kajiyama, Takasi; Numata, Kazuaki; Ohtani, Seiji [Quality Assuranse Section, Technical Administration Division, Plutonium Fuel Center, Tokai Works, Japan Nuclear Cycle Development Inst., Tokai, Ibaraki (Japan); Kobayashi, Hiromi; Watanabe, Hiroaki; Goto, Tatsuro; Takahashi, Hideki; Nagasaku, Katsuhiko [Inspection Development Campany Ltd., Tokai, Ibaraki (Japan)

    2000-02-01

    The procedure and result of lower endplugwelding, Test and Inspection and Shipment of the 1{sup th} reload core fuel assembly (80 Fuel Assemblies) for the fast breeder reactor MONJU are reported, which had been examined and inspected in Tamatsukuri Branch, Material Insurance Office, Quality Assurance Section, Technical Administration Division, Plutonium Fuel Center (before: Inspection Section, Plutonium Fuel Division), from June 1994 to January 1996. The number of cladding tubes welded to the endplug were totally 13,804: 7,418 for Core - Inside of 43 fuel Assemblies and 6,836 for Core-Outside of 37 fuel Assemblies. 13,794 of them, 7,414 Core-Inside and 6,379 Core-Outside, were approved by the test and sent to Plutonium Fuel Center. 10 of them weren't approved mainly because of default welding. Disapproval rating was 0.07%. (author)

  3. 16 x 16 Vantage+ Fuel Assembly Flow Vibrational Testing

    International Nuclear Information System (INIS)

    Chambers, Martin; Kurincic, Bojan

    2014-01-01

    Nuklearna Elektrarna Krsko (NEK) has experienced leaking fuel after increasing the cycle duration to 18 months. The leaking fuel mechanism has predominantly been consistent over multiple cycles and is typically observed in highly irradiated Fuel Assemblies (FA) after around 4 years of continuous operation that were located at the core periphery (baffle). The cause of the leaking fuel is due to Grid-To-Rod-Fretting (GRTF) and occasional debris fretting. NEK utilises a 16x16 Vantage+ FA design with all Inconel structural mixing vane grids (8 in total), Zirlo thimbles, Integral Fuel Burnable Absorber (IFBA) rods with enriched ZrB2, enriched Annular Blanket, Debris Filter Bottom Nozzle (DFBN), Removable Top Nozzle (RTN) and Zirlo fuel cladding material with a high burnup capability of 60 GWD/MTU. Numerous design and operational changes are thought to have reduced the original 16x16 FA design margin to fretting resistance of either vibration or its wear work rate, such as significant power uprate (spring force loss, rod creep down...), operational cycle duration increase from 12 to 18 months (increasing residence time as well as lead FA and fuel rod burnup values), Reactor Coolant System flow increase (increased vibration), removal of Thimble Plugs (increased bypass flow, increased vibration) and Zirc-4 to Zirlo cladding change (decreasing wear work rate). The fuel rod to grid spring as well as dimple contact areas are relatively smaller than other FA designs that exhibit good in-reactor fretting performance. A FA design change project to address the small rod to dimple / spring contact area and utilise fuel cladding oxide coating is currently being pursued with the fuel supplier. The FA vibrational properties are very important to the in-reactor FA performance and reliability. The 16x16 Vantage+ vibrational testing was performed with a full size FA in the Fuel Assembly Compatibility Testing (FACTS) loop that is able to provide full flow rates at elevated temperature

  4. FAITH – Fast Assembly Inhibitor Test for HIV

    Energy Technology Data Exchange (ETDEWEB)

    Hadravová, Romana [Institute of Organic Chemistry and Biochemistry IOCB Research Centre & Gilead Sciences, Academy of Sciences of the Czech Republic, Flemingovo nám. 2, 166 10 Prague (Czech Republic); Rumlová, Michaela, E-mail: michaela.rumlova@vscht.cz [Institute of Organic Chemistry and Biochemistry IOCB Research Centre & Gilead Sciences, Academy of Sciences of the Czech Republic, Flemingovo nám. 2, 166 10 Prague (Czech Republic); Department of Biotechnology, University of Chemistry and Technology, Prague, Technická 5, 166 28 Prague (Czech Republic); Ruml, Tomáš, E-mail: tomas.ruml@vscht.cz [Department of Biochemistry and Microbiology, University of Chemistry and Technology, Prague, Technická 3, 166 28 Prague (Czech Republic)

    2015-12-15

    Due to the high number of drug-resistant HIV-1 mutants generated by highly active antiretroviral therapy (HAART), there is continuing demand for new types of inhibitors. Both the assembly of the Gag polyprotein into immature and mature HIV-1 particles are attractive candidates for the blocking of the retroviral life cycle. Currently, no therapeutically-used assembly inhibitor is available. One possible explanation is the lack of a reliable and simple assembly inhibitor screening method. To identify compounds potentially inhibiting the formation of both types of HIV-1 particles, we developed a new fluorescent high-throughput screening assay. This assay is based on the quantification of the assembly efficiency in vitro in a 96-well plate format. The key components of the assay are HIV-1 Gag-derived proteins and a dual-labelled oligonucleotide, which emits fluorescence only when the assembly of retroviral particles is inhibited. The method was validated using three (CAI, BM2, PF74) reported assembly inhibitors. - Highlights: • Allows screening of assembly inhibitors of both mature and immature HIV-1 particles. • Based on Gag-derived proteins with CA in mature or immature conformation. • Simple and sensitive method suitable for high-throughput screening of inhibitors. • Unlike in other HIV assembly methods, works under physiological conditions. • No washing steps are necessary.

  5. FAITH – Fast Assembly Inhibitor Test for HIV

    International Nuclear Information System (INIS)

    Hadravová, Romana; Rumlová, Michaela; Ruml, Tomáš

    2015-01-01

    Due to the high number of drug-resistant HIV-1 mutants generated by highly active antiretroviral therapy (HAART), there is continuing demand for new types of inhibitors. Both the assembly of the Gag polyprotein into immature and mature HIV-1 particles are attractive candidates for the blocking of the retroviral life cycle. Currently, no therapeutically-used assembly inhibitor is available. One possible explanation is the lack of a reliable and simple assembly inhibitor screening method. To identify compounds potentially inhibiting the formation of both types of HIV-1 particles, we developed a new fluorescent high-throughput screening assay. This assay is based on the quantification of the assembly efficiency in vitro in a 96-well plate format. The key components of the assay are HIV-1 Gag-derived proteins and a dual-labelled oligonucleotide, which emits fluorescence only when the assembly of retroviral particles is inhibited. The method was validated using three (CAI, BM2, PF74) reported assembly inhibitors. - Highlights: • Allows screening of assembly inhibitors of both mature and immature HIV-1 particles. • Based on Gag-derived proteins with CA in mature or immature conformation. • Simple and sensitive method suitable for high-throughput screening of inhibitors. • Unlike in other HIV assembly methods, works under physiological conditions. • No washing steps are necessary.

  6. California; Antelope Valley Air Quality Management District; VOCs from Motor Vehicle Assembly Coating Operations

    Science.gov (United States)

    EPA is proposing to approve a revision to the Antelope Valley Air Quality Management District portion of the California SIP concerning emissions of volatile organic compounds (VOCs) from motor vehicle assembly coating operations.

  7. Preliminary study for the reliability Assurance on results and procedure of the out-pile mechanical characterization test for a fuel assembly; Lateral Vibration Test (I)

    International Nuclear Information System (INIS)

    Lee, Kang Hee; Yoon, Kyung Hee; Kim, Hyung Kyu

    2007-01-01

    The reliability assurance with respect to the test procedure and results of the out-pile mechanical performance test for the nuclear fuel assembly is an essential task to assure the test quality and to get a permission for fuel loading into the commercial reactor core. For the case of vibration test, proper management and appropriate calibration of instruments and devices used in the test, various efforts to minimize the possible error during the test and signal acquisition process are needed. Additionally, the deep understanding both of the theoretical assumption and simplification for the signal processing/modal analysis and of the functions of the devices used in the test were highly required. In this study, the overall procedure and result of lateral vibration test were assembly's mechanical characterization were briefly introduced. A series of measures to assure and improve the reliability of the vibration test were discussed

  8. Preliminary study for the reliability Assurance on results and procedure of the out-pile mechanical characterization test for a fuel assembly; Lateral Vibration Test (I)

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kang Hee; Yoon, Kyung Hee; Kim, Hyung Kyu [KAERI, Daejeon (Korea, Republic of)

    2007-07-01

    The reliability assurance with respect to the test procedure and results of the out-pile mechanical performance test for the nuclear fuel assembly is an essential task to assure the test quality and to get a permission for fuel loading into the commercial reactor core. For the case of vibration test, proper management and appropriate calibration of instruments and devices used in the test, various efforts to minimize the possible error during the test and signal acquisition process are needed. Additionally, the deep understanding both of the theoretical assumption and simplification for the signal processing/modal analysis and of the functions of the devices used in the test were highly required. In this study, the overall procedure and result of lateral vibration test were assembly's mechanical characterization were briefly introduced. A series of measures to assure and improve the reliability of the vibration test were discussed.

  9. Pursuing the Qualities of a "Good" Test

    Science.gov (United States)

    Coniam, David

    2014-01-01

    This article examines the issue of the quality of teacher-produced tests, limiting itself in the current context to objective, multiple-choice tests. The article investigates a short, two-part 20-item English language test. After a brief overview of the key test qualities of reliability and validity, the article examines the two subtests in terms…

  10. System support software for TSTA [Tritium Systems Test Assembly

    International Nuclear Information System (INIS)

    Claborn, G.W.; Mann, L.W.; Nielson, C.W.

    1987-10-01

    The fact that Tritium Systems Test Assembly (TSTA) is an experimental facility makes it impossible and undesirable to try to forecast the exact software requirements. Thus the software had to be written in a manner that would allow modifications without compromising the safety requirements imposed by the handling of tritium. This suggested a multi-level approach to the software. In this approach (much like the ISO network model) each level is isolated from the level below and above by cleanly defined interfaces. For example, the subsystem support level interfaces with the subsystem hardware through the software support level. Routines in the software support level provide operations like ''OPEN VALVE'' and CLOSE VALVE'' to the subsystem level. This isolates the subsystem level from the actual hardware. This is advantageous because changes can occur in any level without the need for propagating the change to any other level. The TSTA control system consists of the hardware level, the data conversion level, the operator interface level, and the subsystem process level. These levels are described

  11. Uncertainties in the Item Parameter Estimates and Robust Automated Test Assembly

    Science.gov (United States)

    Veldkamp, Bernard P.; Matteucci, Mariagiulia; de Jong, Martijn G.

    2013-01-01

    Item response theory parameters have to be estimated, and because of the estimation process, they do have uncertainty in them. In most large-scale testing programs, the parameters are stored in item banks, and automated test assembly algorithms are applied to assemble operational test forms. These algorithms treat item parameters as fixed values,…

  12. Using Set Covering with Item Sampling to Analyze the Infeasibility of Linear Programming Test Assembly Models

    Science.gov (United States)

    Huitzing, Hiddo A.

    2004-01-01

    This article shows how set covering with item sampling (SCIS) methods can be used in the analysis and preanalysis of linear programming models for test assembly (LPTA). LPTA models can construct tests, fulfilling a set of constraints set by the test assembler. Sometimes, no solution to the LPTA model exists. The model is then said to be…

  13. Irradiation Testing Vehicles for Fast Reactors from Open Test Assemblies to Closed Loops

    Energy Technology Data Exchange (ETDEWEB)

    Sienicki, James J. [Argonne National Lab. (ANL), Argonne, IL (United States); Grandy, Christopher [Argonne National Lab. (ANL), Argonne, IL (United States)

    2016-12-15

    A review of irradiation testing vehicle approaches and designs that have been incorporated into past Sodium-Cooled Fast Reactors (SFRs) or envisioned for incorporation has been carried out. The objective is to understand the essential features of the approaches and designs so that they can inform test vehicle designs for a future U.S. Fast Test Reactor. Fast test reactor designs examined include EBR-II, FFTF, JOYO, BOR-60, PHÉNIX, JHR, and MBIR. Previous designers exhibited great ingenuity in overcoming design and operational challenges especially when the original reactor plant’s mission changed to an irradiation testing mission as in the EBRII reactor plant. The various irradiation testing vehicles can be categorized as: Uninstrumented open assemblies that fit into core locations; Instrumented open test assemblies that fit into special core locations; Self-contained closed loops; and External closed loops. A special emphasis is devoted to closed loops as they are regarded as a very desirable feature of a future U.S. Fast Test Reactor. Closed loops are an important technology for irradiation of fuels and materials in separate controlled environments. The impact of closed loops on the design of fast reactors is also discussed in this report.

  14. Mobile work station concept for assembly of large space structures (zero gravity simulation tests)

    Science.gov (United States)

    Heard, W. L., Jr.; Bush, H. G.; Wallsom, R. E.; Jensen, J. K.

    1982-03-01

    The concept presented is intended to enhance astronaut assembly of truss structure that is either too large or complex to fold for efficient Shuttle delivery to orbit. The potential of augmented astronaut assembly is illustrated by applying the result of the tests to a barebones assembly of a truss structure. If this structure were assembled from the same nestable struts that were used in the Mobile Work Station assembly tests, the spacecraft would be 55 meters in diameter and consist of about 500 struts. The struts could be packaged in less than 1/2% of the Shuttle cargo bay volume and would take up approximately 3% of the mass lift capability. They could be assembled in approximately four hours. This assembly concept for erectable structures is not only feasible, but could be used to significant economic advantage by permitting the superior packaging feature of erectable structures to be exploited and thereby reduce expensive Shuttle delivery flights.

  15. Pressure drop performance evaluation for test assemblies with the newly developed top and bottom nozzles

    International Nuclear Information System (INIS)

    Lee, S. K.; Park, N. K.; Su, J. M.; Kim, H. K.; Lee, J. N.; Kim, K. T.

    2003-01-01

    To perform the hydraulic test for the newly developed top and bottom nozzles, two kinds of test assemblies were manufactured i. e. one is the test assembly which has the newly developed top and bottom nozzles and the other is Guardian test assembly which is commercially in mass production now. The test results show that the test assembly with one top nozzle and two bottom nozzles has a greater pressure loss coefficient than Guardian test assembly by 60.9% and 90.4% at the bottom nozzle location. This cause is due to the debris filtering plate for bottom nozzle to improve a filtering efficiency aginst foreign material. In the region of mid grid and top nozzle, there is no difference in pressure loss coefficient between the test assemblies since the componet features in these regions are very similar or same each other. The loss coefficients are 14.2% and 21.9% for model A and B respectively in the scale of test assembly, and the value would be within the 10% in the scale of real fuel assembly. As a result of hydraulic performance evaluation, model A is superior to model B

  16. Assembly Test of Elastic Averaging Technique to Improve Mechanical Alignment for Accelerating Structure Assemblies in CLIC

    CERN Document Server

    Huopana, J

    2010-01-01

    The CLIC (Compact LInear Collider) is being studied at CERN as a potential multi-TeV e+e- collider [1]. The manufacturing and assembly tolerances for the required RF-components are important for the final efficiency and for the operation of CLIC. The proper function of an accelerating structure is very sensitive to errors in shape and location of the accelerating cavity. This causes considerable issues in the field of mechanical design and manufacturing. Currently the design of the accelerating structures is a disk design. Alternatively it is possible to create the accelerating assembly from quadrants, which favour the mass manufacturing. The functional shape inside of the accelerating structure remains the same and a single assembly uses less parts. The alignment of these quadrants has been previously made kinematic by using steel pins or spheres to align the pieces together. This method proved to be a quite tedious and time consuming method of assembly. To limit the number of different error sources, a meth...

  17. 49 CFR 572.145 - Upper and lower torso assemblies and torso flexion test procedure.

    Science.gov (United States)

    2010-10-01

    ...) ANTHROPOMORPHIC TEST DEVICES 3-year-Old Child Crash Test Dummy, Alpha Version § 572.145 Upper and lower torso... lumbar spine and abdomen of a fully assembled dummy (drawing 210-0000) to flexion articulation between... in paragraph (c) of this section, the lumbar spine-abdomen assembly shall flex by an amount that...

  18. Operational Testing and Measurement of the Resolving Time of a Counting Assembly

    International Nuclear Information System (INIS)

    Manent, G.; Scheemaecker, J. de

    1968-01-01

    An experiment is described which constitutes a very sensitive test of the satisfactory operation of a counting assembly. It makes it possible to measure the resolving time of an assembly to an accuracy of 1 per cent. A certain number of examples are presented which show the sensitivity of the test. (author) [fr

  19. Closed Loop In-Reactor Assembly (CLIRA): a fast flux test facility test vehicle

    International Nuclear Information System (INIS)

    Oakley, D.J.

    1978-01-01

    The Closed Loop In-Reactor Assembly (CLIRA) is a test vehicle for in-core material and fuel experiments in the Fast Flux Test Facility (FFTF). The FFTF is a fast flux nuclear test reactor operated for the Department of Energy (DOE) by Westinghouse Hanford Company in Richland, Washington. The CLIRA is a removable/replaceable part of the Closed Loop System (CLS) which is a sodium coolant system providing flow and temperature control independent of the reactor coolant system. The primary purpose of the CLIRA is to provide a test vehicle which will permit testing of nuclear fuels and materials at conditions more severe than exist in the FTR core, and to isolate these materials from the reactor core

  20. Assembly and method for testing the integrity of stuffing tubes

    Energy Technology Data Exchange (ETDEWEB)

    Morrison, E.F.

    1996-12-31

    A stuffing tube integrity checking assembly includes first and second annular seals, with each seal adapted to be positioned about a stuffing tube penetration component. An annular inflation bladder is provided, the bladder having a slot extending longitudinally there along and including a separator for sealing the slot. A first valve is in fluid communication with the bladder for introducing pressurized fluid to the space defined by the bladder when mounted about the tube. First and second releasible clamps are provided. Each clamp assembly is positioned about the bladder for securing the bladder to one of the seals for thereby establishing a fluid-tight chamber about the tube.

  1. Challenges, Solutions, and Quality Metrics of Personal Genome Assembly in Advancing Precision Medicine

    Directory of Open Access Journals (Sweden)

    Wenming Xiao

    2016-04-01

    Full Text Available Even though each of us shares more than 99% of the DNA sequences in our genome, there are millions of sequence codes or structure in small regions that differ between individuals, giving us different characteristics of appearance or responsiveness to medical treatments. Currently, genetic variants in diseased tissues, such as tumors, are uncovered by exploring the differences between the reference genome and the sequences detected in the diseased tissue. However, the public reference genome was derived with the DNA from multiple individuals. As a result of this, the reference genome is incomplete and may misrepresent the sequence variants of the general population. The more reliable solution is to compare sequences of diseased tissue with its own genome sequence derived from tissue in a normal state. As the price to sequence the human genome has dropped dramatically to around $1000, it shows a promising future of documenting the personal genome for every individual. However, de novo assembly of individual genomes at an affordable cost is still challenging. Thus, till now, only a few human genomes have been fully assembled. In this review, we introduce the history of human genome sequencing and the evolution of sequencing platforms, from Sanger sequencing to emerging “third generation sequencing” technologies. We present the currently available de novo assembly and post-assembly software packages for human genome assembly and their requirements for computational infrastructures. We recommend that a combined hybrid assembly with long and short reads would be a promising way to generate good quality human genome assemblies and specify parameters for the quality assessment of assembly outcomes. We provide a perspective view of the benefit of using personal genomes as references and suggestions for obtaining a quality personal genome. Finally, we discuss the usage of the personal genome in aiding vaccine design and development, monitoring host

  2. [Quality assurance in human genetic testing].

    Science.gov (United States)

    Stuhrmann-Spangenberg, Manfred

    2015-02-01

    Advances in technical developments of genetic diagnostics for more than 50 years, as well as the fact that human genetic testing is usually performed only once in a lifetime, with additional impact for blood relatives, are determining the extraordinary importance of quality assurance in human genetic testing. Abidance of laws, directives, and guidelines plays a major role. This article aims to present the major laws, directives, and guidelines with respect to quality assurance of human genetic testing, paying careful attention to internal and external quality assurance. The information on quality assurance of human genetic testing was obtained through a web-based search of the web pages that are referred to in this article. Further information was retrieved from publications in the German Society of Human Genetics and through a PubMed-search using term quality + assurance + genetic + diagnostics. The most important laws, directives, and guidelines for quality assurance of human genetic testing are the gene diagnostics law (GenDG), the directive of the Federal Medical Council for quality control of clinical laboratory analysis (RiliBÄK), and the S2K guideline for human genetic diagnostics and counselling. In addition, voluntary accreditation under DIN EN ISO 15189:2013 offers a most recommended contribution towards quality assurance of human genetic testing. Legal restraints on quality assurance of human genetic testing as mentioned in § 5 GenDG are fulfilled once RiliBÄK requirements are followed.

  3. ROSA-IV Large Scale Test Facility (LSTF) system description for second simulated fuel assembly

    International Nuclear Information System (INIS)

    1990-10-01

    The ROSA-IV Program's Large Scale Test Facility (LSTF) is a test facility for integral simulation of thermal-hydraulic response of a pressurized water reactor (PWR) during small break loss-of-coolant accidents (LOCAs) and transients. In this facility, the PWR core nuclear fuel rods are simulated using electric heater rods. The simulated fuel assembly which was installed during the facility construction was replaced with a new one in 1988. The first test with this second simulated fuel assembly was conducted in December 1988. This report describes the facility configuration and characteristics as of this date (December 1988) including the new simulated fuel assembly design and the facility changes which were made during the testing with the first assembly as well as during the renewal of the simulated fuel assembly. (author)

  4. Quality Assurance Tests of the LHCb VELO Modules

    CERN Document Server

    Marinho, Franciole

    2007-01-01

    The LHCb experiment has a dedicated vertex detector (VELO) to measure the particle’s tracks close to the interaction point. This paper describes the main steps of the quality assurance tests performed during assembly, reception and installation of the LHCb VELO modules. Visual inspection, electrical tests, thermal tests and metrology measurements were made. A burn-in test of the modules was performed in a vacuum environment similar to that of the LHCb experiment. The signal to noise of the sensors was estimated to be 20.4 3.0 for R sensors and 22.4 3 0 for Φ sensors. The modules were tested up to 350 V and the leakage current of the modules did not exceed 20µA at any stage of the testing. Only 0.6% of channels were found to be noisy or not fully functional. The acceptable operating pressures of the modules in vacuum was also evaluated.

  5. Data Organization for Quality Control Test

    International Nuclear Information System (INIS)

    Yahaya Talib; Glam Hadzir Patai Mohamad; Wan Hamirul Bahrin Wan Kamal

    2011-01-01

    Test data and results for quality control of Mo-99/ Tc-99m generator shall be organized properly. A computer program was developed using Visual Basic 6.0 to process test data, store data and results to specific folder, generate test reports and certificates. Its performance has been evaluated and tested. (author)

  6. Installation and Quality Assurance of the Interconnections between Cryo-assemblies of the LHC Long Straight Sections

    CERN Document Server

    Garion, C; Tock, J P

    2006-01-01

    The interconnections between the cryomagnets and cryogenic utilities in the LHC long Straight Sections constitute the last machine installation activity. They are ensuring continuity of the beam and insulation vacuum systems, cryogenic fluid and electrical circuits and thermal insulation. The assembly is carried out in a constraining tunnel environment with restricted space. Therefore, the assembly sequence has to be well defined and specific tests have to be performed during the interconnection work to secure the reliability of the system and thus to ensure the global accelerator availability. The LHC has 8 long straight insertion zones composed of special cryomagnets involving specific interconnection procedures and QA plans. The aim of this paper is to present the installation and quality assurance procedures implemented for the LHC LSS interconnections. Technologies such as manual and automatic welding and resistive soldering will be described as well as the different quality controls, such as visual and ...

  7. Validation of PWR core seismic models with shaking table tests on interacting scale 1 fuel assemblies

    International Nuclear Information System (INIS)

    Viallet, E.; Bolsee, G.; Ladouceur, B.; Goubin, T.; Rigaudeau, J.

    2003-01-01

    The fuel assembly mechanical strength must be justified with respect to the lateral loads under accident conditions, in particular seismic loads. This justification is performed by means of time-history analyses with dynamic models of an assembly row in the core, allowing for assembly deformations, impacts at grid locations and reactor coolant effects. Due to necessary simplifications, the models include 'equivalent' parameters adjusted with respect to dynamic characterisation tests of the fuel assemblies. Complementing such tests on isolated assemblies by an overall model validation with shaking table tests on interacting assemblies is obviously desirable. Seismic tests have been performed by French CEA (Commissariat a l'Energie Atomique) on a row of six full scale fuel assemblies, including two types of 17 x 17 12ft design. The row models are built according to the usual procedure, with preliminary characterisation tests performed on a single assembly. The test-calculation comparisons are made for two test configurations : in air and in water. The relatively large number of accelerograms (15, used for each configuration) is also favourable to significant comparisons. The results are presented for the impact forces at row ends, displacements at mid assembly, and also 'statistical' parameters. Despite a non-negligible scattering in the results obtained with different accelerograms, the calculations prove realistic, and the modelling process is validated with a good confidence level. This satisfactory validation allows to evaluate precisely the margins in the seismic design methodology of the fuel assemblies, and thus to confirm the safety of the plants in case of seismic event. (author)

  8. A study for the development of the capsule assembly machine for the re-irradiation test

    International Nuclear Information System (INIS)

    Kang, Y. H.; Kim, J. K.; Yeom, K. Y.; Yoon, K. B.; Choi, M. H.; Kim, B. K.

    2004-01-01

    A series of in-pile tests are being carried out to support the advanced fuel development programs at the HANARO reactor. There are still some limitations for satisfying the test requirements. To meet the demands for the high burnup test at HANARO, new capsule assembling technology is required. This paper describes the design requirements, design and fabrication of the mockup, and pre-operational tests performed for the development of the new capsule assembly machine. The mockup manufactured consists of a base plate, a capsule stand, a capsule guide pipe and clamping device and is 1m in outer diameter, 1.8m in height and 136kg in weight. From the pre-operation tests, the optimum clamping torque was 450kgf·cm for preventing rotation and shaking of the capsule main body during assembling capsule main body and protection tube, and this remote assembling procedure can be applicable to the high burnup test

  9. Development and verification testing of automation and robotics for assembly of space structures

    Science.gov (United States)

    Rhodes, Marvin D.; Will, Ralph W.; Quach, Cuong C.

    1993-01-01

    A program was initiated within the past several years to develop operational procedures for automated assembly of truss structures suitable for large-aperture antennas. The assembly operations require the use of a robotic manipulator and are based on the principle of supervised autonomy to minimize crew resources. A hardware testbed was established to support development and evaluation testing. A brute-force automation approach was used to develop the baseline assembly hardware and software techniques. As the system matured and an operation was proven, upgrades were incorprated and assessed against the baseline test results. This paper summarizes the developmental phases of the program, the results of several assembly tests, the current status, and a series of proposed developments for additional hardware and software control capability. No problems that would preclude automated in-space assembly of truss structures have been encountered. The current system was developed at a breadboard level and continued development at an enhanced level is warranted.

  10. Packaging and transport case of test fuel assembly irradiated in the Creys-Malville reactor

    International Nuclear Information System (INIS)

    Geffroy, J.; Vivien, J.; Pouard, M.; Dujardin, G.N.; Veron, B.; Michoux, H.

    1986-06-01

    Some irradiated fuel assemblies from the fast neutron Creys Malville reactor will be sent to hot laboratories to follow fuel behavior. These test assemblies will be examined after a limited cooling time and transport is realized at high residual power (about 10kW) and cladding temperature should not rise over 500deg C. The fuel assemblies are not dismantled and transported into sodium. The assembly is placed into a case containing sodium plugged and put into a packaging. Dimensioning, thermal behavior, radiation protection and containment are examined [fr

  11. Statistical Methods in Assembly Quality Management of Multi-Element Products on Automatic Rotor Lines

    Science.gov (United States)

    Pries, V. V.; Proskuriakov, N. E.

    2018-04-01

    To control the assembly quality of multi-element mass-produced products on automatic rotor lines, control methods with operational feedback are required. However, due to possible failures in the operation of the devices and systems of automatic rotor line, there is always a real probability of getting defective (incomplete) products into the output process stream. Therefore, a continuous sampling control of the products completeness, based on the use of statistical methods, remains an important element in managing the quality of assembly of multi-element mass products on automatic rotor lines. The feature of continuous sampling control of the multi-element products completeness in the assembly process is its breaking sort, which excludes the possibility of returning component parts after sampling control to the process stream and leads to a decrease in the actual productivity of the assembly equipment. Therefore, the use of statistical procedures for continuous sampling control of the multi-element products completeness when assembled on automatic rotor lines requires the use of such sampling plans that ensure a minimum size of control samples. Comparison of the values of the limit of the average output defect level for the continuous sampling plan (CSP) and for the automated continuous sampling plan (ACSP) shows the possibility of providing lower limit values for the average output defects level using the ACSP-1. Also, the average sample size when using the ACSP-1 plan is less than when using the CSP-1 plan. Thus, the application of statistical methods in the assembly quality management of multi-element products on automatic rotor lines, involving the use of proposed plans and methods for continuous selective control, will allow to automating sampling control procedures and the required level of quality of assembled products while minimizing sample size.

  12. Testing plutonium fuel assembly production for fast-neutron reactors

    International Nuclear Information System (INIS)

    Nougues, B.; Benhamou, A.; Bertothy, G.; Lepetit, H.

    1975-01-01

    The main characteristics of plutonium fuel elements for fast breeder reactors justify specific test procedures and special techniques. The specific tests relating to the Pu content consist of Pu enrichment and distribution tests, determination of the O/M ratio and external contamination tests. The specific tests performed on fuel configuration are: testing of sintered pellet diameter, testing of pin welding and checking of internal assmbly [fr

  13. Assembly and testing of microparticle and microcapsule smart tattoo materials

    Science.gov (United States)

    McShane, Michael J.

    2007-01-01

    Microscale biochemical sensors are attractive for in vitro diagnostics and disease management, as well as medical and biological research applications. Fluorescent sensors, coupling specific glucose-binding proteins with fluorescent readout methods, have been developed for this purpose. Our work has focused on the development of assembly and packaging systems for producing micro- and nanoscale sensing components that can be used as implants, intracellular reporters, or as elements in larger systems. Both hybrid organic/inorganic particles and hollow microshells have been developed to physically couple the sensing materials together in biocompatible, semipermeable packages. Fabrication details and sensor characterization are used to demonstrate the potential of these sensor concepts.

  14. Design of a mixed-oxide fuel assembly to be assessed as a lead test assembly in a BWR reactor

    International Nuclear Information System (INIS)

    Hernandez, H.; Alonso, G.

    2001-01-01

    The open and the close cycle are the two alternatives to pursue during power generation. The reprocessing is a mature process that now shows a more competitive economic aspect, making it more attractive than ever. Mexico has not decided what to do with the existing and future depleted fuel assemblies that will be generated from the power operation, thus the direct disposal and the reprocessing are still being considered. To have enough arguments in one or the other alternatives it is necessary to make an assessment of both. This investigation focus in the MOX fuel design assuming that the reprocessing is the option to follow and looking for the lowest impact in power generation. The first step in a reprocessing program is to analyze the performance of four lead test assemblies (LTA's), thus in this investigation we design the corresponding MOX to be used as LTA's and assess their performance through one operational cycle. (author)

  15. Environmental Exposure and Accelerated Testing of Rubber-to-Metal Vulcanized Bonded Assemblies

    Science.gov (United States)

    1974-11-01

    btadiene/acrylonitrile ( NBR ) rubber -to-metat -. canized bonded assemblies at the two exposure sites are shown in Table 5. After exposure for one year...AD-A0-17 368 EN~VIRONMENTAL EXPOSURE AND ACCELERATED TESTING OF RUBBER -TO-METAL VULCANIZED BONDED ASSEMBLIES John A. WilliamsI Rock Island Arseital...COMMERCE 325116 1AD R-TR-75-013 ENViRONMENTAL EXPOSURE AND ACCELERATED TESTING OF RUBBER -TO-METAL VULCANIZED BONDED ASSEMBLIES by __ John A. Williams

  16. Hybrid Wing Body Multi-Bay Test Article Analysis and Assembly Final Report

    Science.gov (United States)

    Velicki, Alexander; Hoffman, Krishna; Linton, Kim A.; Baraja, Jaime; Wu, Hsi-Yung T.; Thrash, Patrick

    2017-01-01

    This report summarizes work performed by The Boeing Company, through its Boeing Research & Technology organization located in Huntington Beach, California, under the Environmentally Responsible Aviation (ERA) project. The report documents work performed to structurally analyze and assemble a large-scale Multi-bay Box (MBB) Test Article capable of withstanding bending and internal pressure loadings representative of a Hybrid Wing Body (HWB) aircraft. The work included fabrication of tooling elements for use in the fabrication and assembly of the test article.

  17. A multiple objective test assembly approach for exposure control problems in Computerized Adaptive Testing

    Directory of Open Access Journals (Sweden)

    Theo J.H.M. Eggen

    2010-01-01

    Full Text Available Overexposure and underexposure of items in the bank are serious problems in operational computerized adaptive testing (CAT systems. These exposure problems might result in item compromise, or point at a waste of investments. The exposure control problem can be viewed as a test assembly problem with multiple objectives. Information in the test has to be maximized, item compromise has to be minimized, and pool usage has to be optimized. In this paper, a multiple objectives method is developed to deal with both types of exposure problems. In this method, exposure control parameters based on observed exposure rates are implemented as weights for the information in the item selection procedure. The method does not need time consuming simulation studies, and it can be implemented conditional on ability level. The method is compared with Sympson Hetter method for exposure control, with the Progressive method and with alphastratified testing. The results show that the method is successful in dealing with both kinds of exposure problems.

  18. [Seed quality test methods of Paeonia suffruticosa].

    Science.gov (United States)

    Cao, Ya-Yue; Zhu, Zai-Biao; Guo, Qiao-Sheng; Liu, Li; Wang, Chang-Lin

    2014-11-01

    In order to optimize the testing methods for Paeonia suffruticosa seed quality, and provide basis for establishing seed testing rules and seed quality standard of P. suffruticosa. The seed quality of P. suffruticosa from different producing areas was measured based on the related seed testing regulations. The seed testing methods for quality items of P. suffruticosa was established preliminarily. The samples weight of P. suffruticosa was at least 7 000 g for purity analysis and was at least 700 g for test. The phenotypic observation and size measurement were used for authenticity testing. The 1 000-seed weight was determined by 100-seed method, and the water content was carried out by low temperature drying method (10 hours). After soaking in distilled water for 24 h, the seeds was treated with different temperature stratifications of day and night (25 degrees C/20 degrees C, day/night) in the dark for 60 d. After soaking in the liquor of GA3 300 mg x L(-1) for 24 h, the P. suffruticos seeds were cultured in wet sand at 15 degrees C for 12-60 days for germination testing. Seed viability was tested by TlC method.

  19. Assembly And Test Of A 120 MM Bore 15 T Nb3Sn Quadrupole For The LHC Upgrade

    International Nuclear Information System (INIS)

    Felice, H.; Caspi, S.; Cheng, D.; Dietderich, D.; Ferracin, P.; Hafalia, R.; Joseph, J.; Lizarazo, J.; Sabbi, G.L.; Wang, X.; Anerella, M.; Ghosh, A.K.; Schmalzle, J.; Wanderer, P.; Ambrosio, G.; Bossert, R.; Zlobin, A.V.

    2010-01-01

    In support of the Large Hadron Collider (LHC) luminosity upgrade, the US LHC Accelerator Research Program (LARP) has been developing a 1-meter long, 120 mm bore Nb 3 Sn IR quadrupole magnet (HQ). With a design short sample gradient of 219 T/m at 1.9 K and a peak field approaching 15 T, one of the main challenges of this magnet is to provide appropriate mechanical support to the coils. Compared to the previous LARP Technology Quadrupole and Long Quadrupole magnets, the purpose of HQ is also to demonstrate accelerator quality features such as alignment and cooling. So far, 8 HQ coils have been fabricated and 4 of them have been assembled and tested in HQ01a. This paper presents the mechanical assembly and test results of HQ01a.

  20. A pH-Regulated Quality Control Cycle for Surveillance of Secretory Protein Assembly

    Science.gov (United States)

    Vavassori, Stefano; Cortini, Margherita; Masui, Shoji; Sannino, Sara; Anelli, Tiziana; Caserta, Imma R.; Fagioli, Claudio; Mossuto, Maria F.; Fornili, Arianna; van Anken, Eelco; Degano, Massimo; Inaba, Kenji; Sitia, Roberto

    2013-01-01

    Summary To warrant the quality of the secretory proteome, stringent control systems operate at the endoplasmic reticulum (ER)-Golgi interface, preventing the release of nonnative products. Incompletely assembled oligomeric proteins that are deemed correctly folded must rely on additional quality control mechanisms dedicated to proper assembly. Here we unveil how ERp44 cycles between cisGolgi and ER in a pH-regulated manner, patrolling assembly of disulfide-linked oligomers such as IgM and adiponectin. At neutral, ER-equivalent pH, the ERp44 carboxy-terminal tail occludes the substrate-binding site. At the lower pH of the cisGolgi, conformational rearrangements of this peptide, likely involving protonation of ERp44’s active cysteine, simultaneously unmask the substrate binding site and −RDEL motif, allowing capture of orphan secretory protein subunits and ER retrieval via KDEL receptors. The ERp44 assembly control cycle couples secretion fidelity and efficiency downstream of the calnexin/calreticulin and BiP-dependent quality control cycles. PMID:23685074

  1. Accelerated thermal and mechanical testing of CSP assemblies

    Science.gov (United States)

    Ghaffarian, R.

    2000-01-01

    Chip Scale Packages (CSP) are now widely used for many electronic applications including portable and telecommunication products. A test vehicle (TV-1) with eleven package types and pitches was built and tested by the JPL MicrotypeBGA Consortium during 1997 to 1999. Lessons learned by the team were published as a guidelines document for industry use. The finer pitch CSP packages which recently became available were indluded in the next test vehicle of the JPL CSP Consortium.

  2. Project assembling and commissioning of a rewetting test facility

    International Nuclear Information System (INIS)

    Rezende, H.C.

    1985-08-01

    A test facility (ITR - Instalacao de Testes de Remolhamento) has been erected at the Thermal-hydraulics Laboratory of CDTN, dedicated to the investigation of the basic phenomena that can occur during the reflood phase of a Loss of Coolant Accident (LOCA) in a Pressurized Water Reactor (PWR), utilizing tubular and annular test sections. The present work consists in a presentation of the facility design and a report of its commissioning. The mechanical aspects of the facility, its power supply system and its instrumentation are described. The results of the instruments calibration and two operational tests are presented and a comparison is done with calculations perfomed usign a computer code. (Author) [pt

  3. Cryogenic Fiber Optic Assemblies for Spaceflight Environments: Design, Manufacturing, Testing, and Integration

    Science.gov (United States)

    Thomes, W. Joe; Ott, Melanie N.; Chuska, Richard; Switzer, Robert; Onuma, Eleanya; Blair, Diana; Frese, Erich; Matyseck, Marc

    2016-01-01

    Fiber optic assemblies have been used on spaceflight missions for many years as an enabling technology for routing, transmitting, and detecting optical signals. Due to the overwhelming success of NASA in implementing fiber optic assemblies on spaceflight science-based instruments, system scientists increasingly request fibers that perform in extreme environments while still maintaining very high optical transmission, stability, and reliability. Many new applications require fiber optic assemblies that will operate down to cryogenic temperatures as low as 20 Kelvin. In order for the fiber assemblies to operate with little loss in optical throughput at these extreme temperatures requires a system level approach all the way from how the fiber assembly is manufactured to how it is held, routed, and integrated. The NASA Goddard Code 562 Photonics Group has been designing, manufacturing, testing, and integrating fiber optics for spaceflight and other high reliability applications for nearly 20 years. Design techniques and lessons learned over the years are consistently applied to developing new fiber optic assemblies that meet these demanding environments. System level trades, fiber assembly design methods, manufacturing, testing, and integration will be discussed. Specific recent examples of ground support equipment for the James Webb Space Telescope (JWST); the Ice, Cloud and Land Elevation Satellite-2 (ICESat-2); and others will be included.

  4. Assembling and testing of laboratory scale grey water treatment system

    OpenAIRE

    Harju, Vilhelmiina

    2010-01-01

    Grey water management and reuse is slowly gaining importance in the management of water resources. The benefits of well organized grey water management is that it offers a tool for coping with water scarcity and reduces the amount of pollution to enter the hydrological cycle. Grey water management aims on using treated grey water in applications which do not require drinking water quality. These non-potable reuse applications include industrial processes, irrigation, toilet flushing and lau...

  5. Full scale tests on remote handled FFTF fuel assembly waste handling and packaging

    International Nuclear Information System (INIS)

    Allen, C.R.; Cash, R.J.; Dawson, S.A.; Strode, J.N.

    1986-01-01

    Handling and packaging of remote handled, high activity solid waste fuel assembly hardware components from spent FFTF reactor fuel assemblies have been evaluated using full scale components. The demonstration was performed using FFTF fuel assembly components and simulated components which were handled remotely using electromechanical manipulators, shielding walls, master slave manipulators, specially designed grapples, and remote TV viewing. The testing and evaluation included handling, packaging for current and conceptual shipping containers, and the effects of volume reduction on packing efficiency and shielding requirements. Effects of waste segregation into transuranic (TRU) and non-transuranic fractions also are discussed

  6. TESTING IN SITU ASSEMBLY WITH THE KEPLER PLANET CANDIDATE SAMPLE

    Energy Technology Data Exchange (ETDEWEB)

    Hansen, Brad M. S. [Department of Physics and Astronomy and Institute of Geophysics and Planetary Physics, University of California Los Angeles, Los Angeles, CA 90095 (United States); Murray, Norm, E-mail: hansen@astro.ucla.edu, E-mail: murray@cita.utoronto.ca [Canadian Institute for Theoretical Astrophysics, 60 St. George Street, University of Toronto, Toronto, ON M5S 3H8 (Canada)

    2013-09-20

    We present a Monte Carlo model for the structure of low-mass (total mass <25 M{sub ⊕}) planetary systems that form by the in situ gravitational assembly of planetary embryos into final planets. Our model includes distributions of mass, eccentricity, inclination, and period spacing that are based on the simulation of a disk of 20 M{sub ⊕}, forming planets around a solar-mass star, and assuming a power-law surface density distribution that drops with distance a as ∝ a {sup –1.5}. The output of the Monte Carlo model is then subjected to the selection effects that mimic the observations of a transiting planet search such as that performed by the Kepler satellite. The resulting comparison of the output to the properties of the observed sample yields an encouraging agreement in terms of the relative frequencies of multiple-planet systems and the distribution of the mutual inclinations when moderate tidal circularization is taken into account. The broad features of the period distribution and radius distribution can also be matched within this framework, although the model underpredicts the distribution of small period ratios. This likely indicates that some dissipation is still required in the formation process. The most striking deviation between the model and observations is in the ratio of single to multiple systems in that there are roughly 50% more single-planet candidates observed than are produced in any model population. This suggests that some systems must suffer additional attrition to reduce the number of planets or increase the range of inclinations.

  7. Analysis of confinement effects for in-water seismic tests on PWR fuel assemblies

    International Nuclear Information System (INIS)

    Broc, Daniel; Queval, Jean-Claude; Rigaudeau, J.; Viallet, E.

    2001-01-01

    In the framework of a comprehensive program on the seismic behaviour of the PWR reactor cores, tests have been performed on a row of six PWR fuel assemblies, with two confinement configurations in water. Global fluid motion along the row is not allowed in the 'full confinement configuration', and is allowed in the 'lateral confinement configuration'. The seismic test results show that the impact forces at assembly grid levels are significantly smaller with the full confinement. This is due to damping, which is found to be larger in this configuration where the average fluid velocity inside the assembly (around the rods) is itself larger. We present analyses of these phenomena from theoretical and experimental standpoint. This involves both fluid models and structural models of the assembly row. (author)

  8. Development of a capsule assembly machine for the re-irradiation tests in HANARO

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Y. H.; Choi, M. H.; Sohn, J. M.; Choo, K. N.; Cho, M. S.; Kim, B. G. [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2008-11-15

    A capsule assembly machine (CAM) for the long term irradiation tests in the HANARO reactor has been designed, developed and demonstrated at the Korea Atomic Energy Reasearch Institute (KAERI). The CAM will provide a technical base for viable re-irradiation servives. This machine will be installed in the reactor service pool of the HANARO reactor. The new assembly technique by using a mockup of the CAM in air demonstrated its suitability for an assembly operation, and for an application of this technique to a reactor. The technique will be upgraded after a commissioning test under water environments. This would be expected to be recommended for a country where an under water canal for transporting irradiated devices and enough space of a hot cell for assembling capsule components are not available.

  9. Test specification for decant pump and winch assembly

    International Nuclear Information System (INIS)

    Staehr, T.W.

    1994-01-01

    This specification provides the requirements for testing of the vertical turbine decant pump including the floating suction arm with load sensing winch control, instrumentation and the associated PLC/PC control system

  10. Quality assurance in the nuclear test program

    International Nuclear Information System (INIS)

    Shearer, J.N.

    1979-01-01

    In February 1979 Test Program laid the ground work for a new quality assurance structure. The new approach was based on the findings and recommendations of the Ad Hoc QA Program Review panel, which are summarized in this report. The new structure places the responsibility for quality assurance in the hands of the line organizations, both in the programmatic and functional elements of the LLL matrix

  11. CHALLENGES OF SOFTWARE QUALITY ASSURANCE AND TESTING

    Directory of Open Access Journals (Sweden)

    Md.Shahadat Hossain

    2018-02-01

    Full Text Available Uncertainty exists in Software Company over the world. Software quality problem is leading issue for the software industry. The issue exists from 40 years or 50 years long. The industry is suffering and closing for this issue. In this circumstance, it is important to address and remove its root cause. Otherwise, day by day industry economic loss will increase. I figure out some vital challenges of software quality assurance and testing which have been facing by software industries. The research focused on several small and medium software companies of the world. This paper represents different category of challenges along with responsible stakeholders. This research finds out that testing tools are available testing elements are available testing process has improved but still software has some testing challenges. My research figured out the bottleneck of challenges and explained in this paper. Here software engineers have scope to improve & overcome those challenges. This paper suggests systematic approach to solve the problem.

  12. Development of Out-pile Test Technology for Fuel Assembly Performance Verification

    Energy Technology Data Exchange (ETDEWEB)

    Chun, Tae Hyun; In, W. K.; Oh, D. S. [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)] (and others)

    2007-03-15

    Out-pile tests with full scale fuel assembly are to verify the design and to evaluate the performance of the final products. HTL for the hydraulic tests and FAMeCT for mechanical/structural tests were constructed in this project. The maximum operating conditions of HTL are 30 bar, 320 .deg. C, and 500 m3/hr. This facility can perform the pressure drop test, fuel assembly uplift test, and flow induced vibration test. FAMeCT can perform the bending and vibration tests. The verification of the developed facilities were carried out by comparing the reference data of the fuel assembly which was obtained at the Westinghouse Co. The compared data showed a good coincidence within uncertainties. FRETONUS was developed for high temperature and high pressure fretting wear simulator and performance test. A performance test was conducted for 500 hours to check the integrity, endurance, data acquisition capability of the simulator. The technology of turbulent flow analysis and finite element analysis by computation was developed. From the establishments of out-pile test facilities for full scale fuel assembly, the domestic infrastructure for PWR fuel development has been greatly upgraded.

  13. Flying spin qualities testing of airplane

    Directory of Open Access Journals (Sweden)

    Kostić Čedomir J.

    2015-01-01

    Full Text Available In this paper is presented the theoretical analysis of origins and characteristics of spinning motion. There are precise explanation of every stage spin flight and basic meaning of notion. Personated equation of motion in spin and equitation of motion airplane in settled spin motion, analysis of them and general recommendation for pilots for recovering from spins. Introduced in valid military and civil specifications flight test demonstration requirements for departure resistance and flying stall and spin qualities testing of airplane. Special attention was given on predicting departure, stall and spin susceptibility and theoretical analysis in the name of magnify flight testing security. There are explanation of test equipment and methodology of flying qualities testing of airplanes. Like a support of this theme are described method and results of flight stall and spin qualities testing of airplane G-4(N-62 super see-gull with precise recommendation for pilots for recovering from spins, from TOC SLI VS (Technical testing center, department for fight testing Air Force of Serbia.

  14. Test-element assembly and loading parameters for the in-pile test of HCPB ceramic pebble beds

    Energy Technology Data Exchange (ETDEWEB)

    Laan, J.G. van der E-mail: vanderlaan@nrg-nl.com; Boccaccini, L.V.; Conrad, R.; Fokkens, J.H.; Jong, M.; Magielsen, A.J.; Pijlgroms, B.J.; Reimann, J.; Stijkel, M.P.; Malang, S

    2002-11-01

    In the framework of developing the helium cooled pebble-bed (HCPB) blanket an irradiation test of pebble-bed assemblies is prepared at the HFR Petten. The test objective is to concentrate on the effect of neutron irradiation on the thermal-mechanical behaviour of the HCPB breeder pebble-bed at DEMO representative levels of temperature and defined thermal-mechanical loads. The paper reports on the project status, and presents the results of pre-tests, material characteristics, the manufacturing of the pebble-bed assemblies, and the nuclear and thermo-mechanical loading parameters.

  15. Spinal cord testing: auditing for quality assurance.

    Science.gov (United States)

    Marr, J A; Reid, B

    1991-04-01

    A quality assurance audit of spinal cord testing as documented by staff nurses was carried out. Twenty-five patient records were examined for accuracy of documented testing and compared to assessments performed by three investigators. A pilot study established interrater reliability of a tool that was designed especially for this study. Results indicated staff nurses failed to meet pre-established 100% standard in all categories of testing when compared with investigator's findings. Possible reasons for this disparity are discussed as well as indications for modifications in the spinal testing record, teaching program and preset standards.

  16. 49 CFR 572.124 - Thorax assembly and test procedure.

    Science.gov (United States)

    2010-10-01

    ... test procedure in paragraph (c) of this section: (1) The maximum sternum displacement (compression... displacement but before reaching the minimum required 38.0 mm (1.5 in) sternum displacement limit shall not exceed 1500 N (337.2 lbf). (2) The internal hysteresis of the ribcage in each impact as determined by the...

  17. Clock and trigger distribution for CBM-TOF quality evaluation of RPC super module detector assemblies

    Science.gov (United States)

    Li, C.; Huang, X.; Cao, P.; Wang, J.; An, Q.

    2018-03-01

    RPC Super module (SM) detector assemblies are used for charged hadron identification in the Time-of-Flight (TOF) spectrometer at the Compressed Baryonic Matter (CBM) experiment. Each SM contains several multi-gap Resistive Plate Chambers (MRPCs) and provides up to 320 electronic channels in total for high-precision time measurements. Time resolution of the Time-to-Digital Converter (TDC) is required to be better than 20 ps. During mass production, the quality of each SM needs to be evaluated. In order to meet the requirements, the system clock signal as well as the trigger signal should be distributed precisely and synchronously to all electronics modules within the evaluation readout system. In this paper, a hierarchical clock and trigger distribution method is proposed for the quality evaluation of CBM-TOF SM detectors. In a first stage, the master clock and trigger module (CTM) allocated in a 6U PXI chassis distributes the clock and trigger signals to the slave CTM in the same chassis. In a second stage, the slave CTM transmits the clock and trigger signals to the TDC readout module (TRM) through one optical link. In a third stage, the TRM distributes the clock and trigger signals synchronously to 10 individual TDC boards. Laboratory test results show that the clock jitter at the third stage is less than 4 ps (RMS) and the trigger transmission latency from the master CTM to the TDC is about 272 ns with 11 ps (RMS) jitter. The overall performance complies well with the required specifications.

  18. Sodium flow distribution in test fuel assembly P-23B

    International Nuclear Information System (INIS)

    Taylor, J.P.S.

    1978-08-01

    Relatively large cladding diametral increases in the exterior fuel pins of HEDL's test fuel subassembly P-23B were successfully explained by a thermal-hydraulic/solid mechanics analysis. This analysis indicates that while at power, the subassembly flow was less than planned and that the fuel pins were considerably displaced and bowed from their nominal position. In accomplishing this analysis, a method was developed to estimate the sodium flow distribution and pin distortions in a fuel subassembly at power

  19. Multidimensional Test Assembly Based on Lagrangian Relaxation Techniques. Research Report 98-08.

    Science.gov (United States)

    Veldkamp, Bernard P.

    In this paper, a mathematical programming approach is presented for the assembly of ability tests measuring multiple traits. The values of the variance functions of the estimators of the traits are minimized, while test specifications are met. The approach is based on Lagrangian relaxation techniques and provides good results for the two…

  20. USNRC-OECD Halden Project fuel behavior test program: experiment data report for test assemblies IFA-226 and IFA 239

    International Nuclear Information System (INIS)

    Laats, E.T.; MacDonald, P.E.; Quapp, W.J.

    1975-12-01

    The experimental data which were obtained from the IFA-226 and IFA-239 test assemblies during operation in the Halden Boiling Water Reactor are reported. Included are cladding elongation, fuel centerline temperature, internal gas pressure, and power history data from IFA-226 which were obtained from November 1971 through April 1974, and cladding elongation, diametral profile, and power history data from IFA-239 covering the period from March 1973 through April 1974. The data, presented in the form of composite graphs, have been analyzed only to the extent necessary to assure that they are reasonable and correct. A description of these mixed oxide fuel test assemblies and their instrumentation is presented. Test pin fabrication history, instrument calibration data, assembly power calibration methods, and the neutron detector data reduction technique are included as appendices

  1. Application of PLUTO Test Facility for U. S. NRC Licensing of a Fuel Assembly

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Dongseok; Shin, Changhwan; Lee, Kanghee; Kang, Heungseok [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2013-10-15

    The fuel assembly of the PLUS-7 loaded in the APR-1400 follows the same schedule. Meanwhile, In July 1998, the U.S. NRC adopted a research plan to address the effects of high burnup from a Loss of Coolant Accident (LOCA). From these programs, several important technical findings for rule revision were obtained. Based on the technical findings, the U. S. NRC has amended the 10 CFR 50.46 which will be proclaimed sooner or later. Through the amendment, a LOCA analysis on the fuel assembly has to show the safety at both a fresh and End of Life (EOL) state. The U. S. NRC has already required EOL effects on seismic/LOCA performance for a fuel assembly since 1998. To obtain U.S NRC licensing of a fuel assembly, based on the amendment of 10CFR50.46, a LOCA analysis of the fuel assembly has to show safety both fresh and EOL states. The proper damping factor of the fuel assembly measured at the hydraulic test loop for a dynamic model in a LOCA and a seismic analysis code are at least required. In this paper, we have examined the damping technologies and compared the test facility of PLUTO with others in terms of performance. PLUTO has a better performance on the operating conditions than any others.

  2. The assembly of the silicon tracker for the GLAST beam test engineering model

    International Nuclear Information System (INIS)

    Allport, P.; Atwood, E.; Atwood, W.; Beck, G.; Bhatnager, B.; Bloom, E.; Broeder, J.; Chen, V.; Clark, J.; Cotton, N.; Couto e Silva, E. do; Feerick, B.; Giebels, G.; Godfrey, G.; Handa, T.; Hernando, J.A.; Hirayama, M.; Johnson, R.P.; Kamae, T.; Kashiguine, S.; Kroeger, W.; Milbury, C.; Miller, W.; Millican, O.; Nikolaou, M.; Nordby, M.; Ohsugi, T.; Paliaga, G.; Ponslet, E.; Rowe, W.; Sadrozinski, H.F.-W.; Spencer, E.; Stromberg, S.; Swensen, E.; Takayuki, M.; Tournear, D.; Webster, A.; Winkler, G.; Yamamoto, K.; Yamamura, K.; Yoshida, S.

    2001-01-01

    The silicon tracker for the engineering model of the GLAST Large Area Telescope (LAT) to date represents the largest surface of silicon microstrip detectors assembled in a tracker (2.7 m 2 ). It demonstrates the feasibility of employing this technology for satellite based experiments, in which large effective areas and high reliability are required. This note gives an overview of the assembly of this silicon tracker and discusses in detail studies performed to track quality assurance: leakage current, mechanical alignment and production yields

  3. Post-Irradiation Examination Test of the Parts of X-Gen Nuclear Fuel Assembly

    International Nuclear Information System (INIS)

    Ahn, S. B.; Ryu, W. S.; Choo, Y. S.

    2008-08-01

    The mechanical properties of the parts of a nuclear fuel assembly are degraded during the operation of the reactor, through the mechanism of irradiation damage. The properties changes of the parts of the fuel assembly should be quantitatively estimated to ensure the safety of the fuel assembly and rod during the operation. The test techniques developed in this report are used to produce the irradiation data of the grid 1x1 cell spring, the grid 1x1 cell, the spring on one face of the 1x1 cell, the inner/outer strip of the grid and the welded part. The specimens were irradiated in the CT test hole of HANARO of a 30 MW thermal output at 300 deg. C during about 100 days From the spring test of mid grid 1x1 cell and grid plate, the irradiation effects can be examined. The irradiation effects on the irradiation growth also were occurred. The buckling load of mid grid 1x1 cell does not change with a neutron irradiation. From the tensile tests, the strengths increased but the elongations decreased due to an irradiation. The tensile test and microstructure examination of the spot and fillet welded parts are performed for the evaluation of an irradiation effects. Through these tests of components, the essential data on the fuel assembly design could be obtained. These results will be used to update the irradiation behavior databases, to improve the performance of fuel assembly, and to predict the service life of the fuel assembly in a reactor

  4. Iowa Central Quality Fuel Testing Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Heach, Don; Bidieman, Julaine

    2013-09-30

    The objective of this project is to finalize the creation of an independent quality fuel testing laboratory on the campus of Iowa Central Community College in Fort Dodge, Iowa that shall provide the exploding biofuels industry a timely and cost-effective centrally located laboratory to complete all state and federal fuel and related tests that are required. The recipient shall work with various state regulatory agencies, biofuel companies and state and national industry associations to ensure that training and testing needs of their members and American consumers are met. The recipient shall work with the Iowa Department of Ag and Land Stewardship on the development of an Iowa Biofuel Quality Standard along with the Development of a standard that can be used throughout industry.

  5. Upgraded Features of Newly Constructed Fuel Assembly Mechanical Characterization Test Facility in KAERI

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kang Hee; Kang, Heung Seok; Yoon, Kyung Ho; Kim, Hyung Kyu; Lee, Young Ho; Kim, Soo Ho; Yang, Jae Ho [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    Fuel assembly mechanical characterization test facility (FAMeCT) in KAERI is newly constructed with upgraded functional features such as increased loading capacity, under-water vibration testing and severe earthquake simulation for extended fuel design guideline. The facility building is compactly designed in the scale of 3rd floor building and has regions for assembly-wise mechanical test equipment, dynamic load (seismic) simulating test system, small scale hydraulic loop and component wise test equipment. Figure 1 shows schematic regional layout of the facility building. Mechanical test platform and system is designed to increase loading capacity for axial compression test. Structural stability of the support system of new upper core plate simulator is validated through a limit case functional test. Fuel assembly mechanical characterization test facility in KAERI is newly constructed and upgraded with advanced functional features such as uprated loading capacity, under-water vibration testing and severe earthquake simulation for extended fuel design guideline. This paper briefly introduce the test facility construction and scope of the facility and is focused on the upgraded design features of the facility. Authors hope to facilitate the facility more in the future and collaborate with the industry.

  6. INSURANCE OF KNITTED PRODUCTS QUALITY THROUGH THE ANALYSIS AND EVALUATION OF NON-QUALITY DURING ASSEMBLY BY STITCHING

    Directory of Open Access Journals (Sweden)

    LUTIC Liliana

    2014-05-01

    Full Text Available In a knitting factory, any activity oriented toward evaluation, maintenance or improvement of products quality level is based on measuring and examining the product quality characteristics, in order to establish conformity to the quality specifications and/or naming the non-quality characteristics, thus noticing defects or fabrication deficiencies. The quality of the stitching operation has a particular influence on the finite product quality and is determined on side by the quality of knitted pieces, and on the other by insuring the correlation between the technological parameters of the stitching operation and the physico-mechanical characteristics of the knittings that are to be assembled through stitching. Although the product execution processes comprise of manufacturing the elements and distinct subassemblies and their ulterior assembly, they present various difference dictated by the constructive particularities of the machine, as well as fabric characteristics. Because of the multiple interactions between the material, yarn and working parts of the sawing machine, inadequacies in the technological discipline can result in negative effects on both the knitted and stitching thread as well as the machine. A part of these can be fixed by extra time consuming tasks (yarn breaks, stitching ruffling etc., while other defects appear during the usage of the product cheapening it (stitch tearing by perforating the knitted on the stitching line, pilling effect, dimensional instability etc.. This paper systematically presents, the main defects that may occur during the stitching operation of the products made out of circular knitted, as well as the causes that generate them along with preventive or corrective actions.

  7. Fast and thermal data testing of 233U critical assemblies

    International Nuclear Information System (INIS)

    Wright, R.Q.; Jordan, W.C.; Leal, L.C.

    1999-01-01

    Many sources have been used to obtain 233 U benchmark descriptions. Unfortunately, some of these are not reliable since a thorough and complete benchmark evaluation often has not been done. For 24 yr a principal source for 233 U benchmarks has been the Cross Section Evaluation Working Group (CSEWG) Benchmark Specifications. The CSEWG specifications included only two fast benchmarks and three thermal benchmarks. The thermal benchmarks were H 2 O-moderated thorium-oxide exponential lattices. Since the thorium-oxide lattices were exponential experiments, they have not been widely used. CSEWG has also used the 233 U Oak Ridge National Laboratory (ORNL) spheres for many years. One advantage of the CSEWG fast benchmarks, JEZEBEL-23 and FLATTOP-23, is that experiments were done for central-reaction-rate ratios. These reaction-rate ratios provide very valuable information to data testers and evaluators that would not otherwise be available. In recent years the International Handbook of Evaluated Criticality Safety Benchmark Experiments has, in general, been a very useful and reliable source. The Handbook does not include central-reaction-rate ratio experiments, however. A new set of 233 U benchmark experiments has been added to the most recent release of the Handbook, U233-SOL-THERM-004. These are paraffin-reflected cylinders of 233 U uranyl-nitrate solutions. Unfortunately, the estimated benchmark uncertainties are on the order of 0.9 to 1.0% in k eff . Benchmark testing has been done for some of these U233-SOL-THERM-004 experiments. The authors have also discovered that the benchmark specifications for the Thomas uranyl-nitrate experiments given in Ref. 5 are incorrect. One problem with the Ref. 5 specifications is that the excess acid was not included. As part of this work, the authors developed revised specifications that include an excess acid correlation based on information from the experimental logbook

  8. Failure analysis of beryllium tile assembles following high heat flux testing for the ITER program

    International Nuclear Information System (INIS)

    Odegard, B.C. Jr.; Cadden, C. H.; Yang, N. Y. C.

    2000-01-01

    The following document describes the processing, testing and post-test analysis of two Be-Cu assemblies that have successfully met the heat load requirements for the first wall and dome sections for the ITER (International Thermonuclear Experimental Reactor) fusion reactor. Several different joint assemblies were evaluated in support of a manufacturing technology investigation aimed at diffusion bonding or brazing a beryllium armor tile to a copper alloy heat sink for fusion reactor applications. Judicious selection of materials and coatings for these assemblies was essential to eliminate or minimize interactions with the highly reactive beryllium armor material. A thin titanium layer was used as a diffusion barrier to isolate the copper heat sink from the beryllium armor. To reduce residual stresses produced by differences in the expansion coefficients between the beryllium and copper, a compliant layer of aluminum or aluminum-beryllium (AlBeMet-150) was used. Aluminum was chosen because it does not chemically react with, and exhibits limited volubility in, beryllium. Two bonding processes were used to produce the assemblies. The primary process was a diffusion bonding technique. In this case, undesirable metallurgical reactions were minimized by keeping the materials in a solid state throughout the fabrication cycle. The other process employed an aluminum-silicon layer as a brazing filler material. In both cases, a hot isostatic press (HIP) furnace was used in conjunction with vacuum-canned assemblies in order to minimize oxidation and provide sufficient pressure on the assemblies for full metal-to-metal contact and subsequent bonding. The two final assemblies were subjected to a suite of tests including: tensile tests and electron and optical metallography. Finally, high heat flux testing was conducted at the electron beam testing system (EBTS) at Sandia National Laboratories, New Mexico. Here, test mockups were fabricated and subjected to normal heat loads to

  9. Streamlined Approach for Environmental Restoration Work Plan for Corrective Action Unit 461: Joint Test Assembly Sites and Corrective Action Unit 495: Unconfirmed Joint Test Assembly Sites Tonopah Test Range, Nevada

    Energy Technology Data Exchange (ETDEWEB)

    Jeff Smith

    1998-08-01

    This Streamlined Approach for Environmental Restoration plan addresses the action necessary for the clean closure of Corrective Action Unit 461 (Test Area Joint Test Assembly Sites) and Corrective Action Unit 495 (Unconfirmed Joint Test Assembly Sites). The Corrective Action Units are located at the Tonopah Test Range in south central Nevada. Closure for these sites will be completed by excavating and evaluating the condition of each artillery round (if found); detonating the rounds (if necessary); excavating the impacted soil and debris; collecting verification samples; backfilling the excavations; disposing of the impacted soil and debris at an approved low-level waste repository at the Nevada Test Site

  10. Subchannel analysis of a critical power test, using simulated BWR 8x8 fuel assembly

    International Nuclear Information System (INIS)

    Mitsutake, T.; Terasaka, H.; Yoshimura, K.; Oishi, M.; Inoue, A.; Akiyama, M.

    1990-01-01

    Critical power predictions have been compared with the critical power test data obtained in simulated BWR 8x8 fuel rod assemblies. Two analytical methods for the critical power prediction in rod assemblies are used in the prediction, which are the subchannel analysis using the COBRA/BWR subchannel computer code with empirical critical heat flux (CHF) correlations and the liquid film dryout estimation using the CRIPP-3F 'multi-fluid' computer code. Improvements in both the analytical methods were made for spacer effect modeling, though they were specific for application to the current BWR rod assembly type. In general a reasonable agreement was obtained, though comparisons, between the prediction and the obtained test data. (orig.)

  11. Mechanical characterization tests of the X2-Gen fuel assembly and skeleton

    International Nuclear Information System (INIS)

    Kim, Hyung Kyu; Yoon, Kyung Ho; Lee, Kang Hee; Kim, Jae Yong; Lee, Young Ho; Kang, Heung Seok

    2011-01-01

    The KNF (KEPCO Nuclear Fuel) requested mechanical characterization tests of a fuel assembly and a skeleton of the X2-Gen fuel. The tests consisted of the lateral vibration and lateral/axial stiffness, lateral/axial impact and combined deflection tests carried out by using the FAMeCT (Fuel Assembly Mechanical Characterization Tester) in KAERI. The upper and lower core plate simulators were newly designed and manufactured because the fuel geometry of the X2-Gen was different from the KSNP type fuel assembly. In addition to this, the upper carriage was also revised with the LM guide system from the previous two guide rods system. Therefore, the axial and combined deflection tests were soundly executed. Each test was repeated twice to confirm the repeatability. The discrepancy from the repetition was small enough to be neglected. The mechanical characterization tests were accredited with the KOLAS (Korea Laboratory Accreditation Scheme) standard, and the certified test reports (lateral vibration, lateral/axial bending and lateral/axial impact) and the uncertified test report (combined deflection) were issued together with the current test result report

  12. Surrogate fuel assembly multi-axis shaker tests to simulate normal conditions of rail and truck transport

    Energy Technology Data Exchange (ETDEWEB)

    McConnell, Paul E. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Koenig, Greg John [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Uncapher, William Leonard [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Grey, Carissa [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Engelhardt, Charles [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Saltzstein, Sylvia J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Sorenson, Ken B. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2016-05-01

    This report describes the third set of tests (the “DCLa shaker tests”) of an instrumented surrogate PWR fuel assembly. The purpose of this set of tests was to measure strains and accelerations on Zircaloy-4 fuel rods when the PWR assembly was subjected to rail and truck loadings simulating normal conditions of transport when affixed to a multi-axis shaker. This is the first set of tests of the assembly simulating rail normal conditions of transport.

  13. Surrogate fuel assembly multi-axis shaker tests to simulate normal conditions of rail and truck transport

    Energy Technology Data Exchange (ETDEWEB)

    McConnell, Paul E. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Koenig, Greg John [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Uncapher, William Leonard [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Grey, Carissa [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Engelhardt, Charles [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Saltzstein, Sylvia J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Sorenson, Ken B. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2016-05-12

    This report describes the third set of tests (the “DCLa shaker tests”) of an instrumented surrogate PWR fuel assembly. The purpose of this set of tests was to measure strains and accelerations on Zircaloy-4 fuel rods when the PWR assembly was subjected to rail and truck loadings simulating normal conditions of transport when affixed to a multi-axis shaker. This is the first set of tests of the assembly simulating rail normal conditions of transport.

  14. Evaluation of GRCh38 and de novo haploid genome assemblies demonstrates the enduring quality of the reference assembly.

    Science.gov (United States)

    Schneider, Valerie A; Graves-Lindsay, Tina; Howe, Kerstin; Bouk, Nathan; Chen, Hsiu-Chuan; Kitts, Paul A; Murphy, Terence D; Pruitt, Kim D; Thibaud-Nissen, Françoise; Albracht, Derek; Fulton, Robert S; Kremitzki, Milinn; Magrini, Vincent; Markovic, Chris; McGrath, Sean; Steinberg, Karyn Meltz; Auger, Kate; Chow, William; Collins, Joanna; Harden, Glenn; Hubbard, Timothy; Pelan, Sarah; Simpson, Jared T; Threadgold, Glen; Torrance, James; Wood, Jonathan M; Clarke, Laura; Koren, Sergey; Boitano, Matthew; Peluso, Paul; Li, Heng; Chin, Chen-Shan; Phillippy, Adam M; Durbin, Richard; Wilson, Richard K; Flicek, Paul; Eichler, Evan E; Church, Deanna M

    2017-05-01

    The human reference genome assembly plays a central role in nearly all aspects of today's basic and clinical research. GRCh38 is the first coordinate-changing assembly update since 2009; it reflects the resolution of roughly 1000 issues and encompasses modifications ranging from thousands of single base changes to megabase-scale path reorganizations, gap closures, and localization of previously orphaned sequences. We developed a new approach to sequence generation for targeted base updates and used data from new genome mapping technologies and single haplotype resources to identify and resolve larger assembly issues. For the first time, the reference assembly contains sequence-based representations for the centromeres. We also expanded the number of alternate loci to create a reference that provides a more robust representation of human population variation. We demonstrate that the updates render the reference an improved annotation substrate, alter read alignments in unchanged regions, and impact variant interpretation at clinically relevant loci. We additionally evaluated a collection of new de novo long-read haploid assemblies and conclude that although the new assemblies compare favorably to the reference with respect to continuity, error rate, and gene completeness, the reference still provides the best representation for complex genomic regions and coding sequences. We assert that the collected updates in GRCh38 make the newer assembly a more robust substrate for comprehensive analyses that will promote our understanding of human biology and advance our efforts to improve health. © 2017 Schneider et al.; Published by Cold Spring Harbor Laboratory Press.

  15. Final Approval of California Air Plan Revision; Antelope Valley Air Quality Management District; VOCs From Motor Vehicle Assembly Coating Operations

    Science.gov (United States)

    EPA is taking final action to approve a revision to the Antelope Valley Air Quality Management District (AVAQMD) portion of the California SIP concerning the emissions of volatile organic compounds (VOCs) from motor vehicle assembly coating operations.

  16. JPLEX: Java Simplex Implementation with Branch-and-Bound Search for Automated Test Assembly

    Science.gov (United States)

    Park, Ryoungsun; Kim, Jiseon; Dodd, Barbara G.; Chung, Hyewon

    2011-01-01

    JPLEX, short for Java simPLEX, is an automated test assembly (ATA) program. It is a mixed integer linear programming (MILP) solver written in Java. It reads in a configuration file, solves the minimization problem, and produces an output file for postprocessing. It implements the simplex algorithm to create a fully relaxed solution and…

  17. Speech production in people who stutter: Testing the motor plan assembly hypothesis

    NARCIS (Netherlands)

    Lieshout, P.H.H.M. van; Hulstijn, W.; Peters, H.F.M.

    1996-01-01

    The main purpose of the present study was to test the hypothesis that persons who stutter, when compared to persons who do not stutter, are less able to assemble abstract motor plans for short verbal responses. Subjects were adult males who stutter and age- and sex-matched control speakers, who were

  18. Automated simultaneous assembly of multi-stage testing for the uniform CPA examination

    NARCIS (Netherlands)

    Breithaupt, Krista; Ariel, A.; Veldkamp, Bernard P.

    2004-01-01

    Some solutions used in the assembly of the computerized Uniform Certified Public Accountancy (CPA) licensing examination are offered as practical alternatives for operational programs producing large numbers of forms. The Uniform CPA examination will be offered as an adaptive multi-stage test (MST)

  19. Automated Test Assembly for Cognitive Diagnosis Models Using a Genetic Algorithm

    Science.gov (United States)

    Finkelman, Matthew; Kim, Wonsuk; Roussos, Louis A.

    2009-01-01

    Much recent psychometric literature has focused on cognitive diagnosis models (CDMs), a promising class of instruments used to measure the strengths and weaknesses of examinees. This article introduces a genetic algorithm to perform automated test assembly alongside CDMs. The algorithm is flexible in that it can be applied whether the goal is to…

  20. Evaluation of tests in 4x4 assemblies carried out in Columbia University

    International Nuclear Information System (INIS)

    Pedron, M.Q.

    1989-01-01

    Tests in 4x4 assemblies with BWR characteristics carried out in Columbia University are analysed, using the PANTERA-1P computer code. The experiments aim for measuring fluid, flow and enthalpies in exits of two subchannels, the coldest and hottest using iso kinetic sampling method. (M.C.K.)

  1. When less is more: 'slicing' sequencing data improves read decoding accuracy and de novo assembly quality.

    Science.gov (United States)

    Lonardi, Stefano; Mirebrahim, Hamid; Wanamaker, Steve; Alpert, Matthew; Ciardo, Gianfranco; Duma, Denisa; Close, Timothy J

    2015-09-15

    As the invention of DNA sequencing in the 70s, computational biologists have had to deal with the problem of de novo genome assembly with limited (or insufficient) depth of sequencing. In this work, we investigate the opposite problem, that is, the challenge of dealing with excessive depth of sequencing. We explore the effect of ultra-deep sequencing data in two domains: (i) the problem of decoding reads to bacterial artificial chromosome (BAC) clones (in the context of the combinatorial pooling design we have recently proposed), and (ii) the problem of de novo assembly of BAC clones. Using real ultra-deep sequencing data, we show that when the depth of sequencing increases over a certain threshold, sequencing errors make these two problems harder and harder (instead of easier, as one would expect with error-free data), and as a consequence the quality of the solution degrades with more and more data. For the first problem, we propose an effective solution based on 'divide and conquer': we 'slice' a large dataset into smaller samples of optimal size, decode each slice independently, and then merge the results. Experimental results on over 15 000 barley BACs and over 4000 cowpea BACs demonstrate a significant improvement in the quality of the decoding and the final assembly. For the second problem, we show for the first time that modern de novo assemblers cannot take advantage of ultra-deep sequencing data. Python scripts to process slices and resolve decoding conflicts are available from http://goo.gl/YXgdHT; software Hashfilter can be downloaded from http://goo.gl/MIyZHs stelo@cs.ucr.edu or timothy.close@ucr.edu Supplementary data are available at Bioinformatics online. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  2. Study of weld quality real-time monitoring system for auto-body assembly

    Science.gov (United States)

    Xu, Jun; Li, Yong-Bing; Chen, Guan-Long

    2005-12-01

    Resistance spot welding (RSW) is widely used for the auto-body assembly in automotive industry. But RSW suffers from a major problem of inconsistent quality from weld to weld. The major problem is the complexity of the basic process that may involve material coatings, electrode force, electrode wear, fit up, etc. Therefore weld quality assurance is still a big challenge and goal. Electrode displacement has proved to be a particularly useful signal which correlates well with weld quality. This paper introduces a novel auto-body spot weld quality monitoring system which uses electrode displacement as the quality parameter. This system chooses the latest laser displacement sensor with high resolution to measure the real-time electrode displacement. It solves the interference problem of sensor mounting by designing special fixture, and can be successfully applied on the portable welding machine. It is capable of evaluating weld quality and making diagnosis of process variations such as surface asperities, shunting, worn electrode and weld expansion with real-time electrode displacement. As proved by application in the workshop, the monitoring system has good stability and reliability, and is qualified for monitoring weld quality in process.

  3. Life-test results on the Zetatron tube, transformer and the tube-transformer assembly

    International Nuclear Information System (INIS)

    Shope, L.A.

    1983-01-01

    In the development of the PFN probe it became evident that some considerable life testing of the neutron tube, high-voltage pulse transformer, and the tube-transformer assembly (TTA) were needed to (1) identify life limiting mechanisms, (2) estimate performance degradation, and (3) provide a data base for end-of-life predictions. Initial results had shown clearly that testing monitored by technicians would be much too costly. Consequently, a computer-controlled and monitored test was developed. This paper describes the test, summarizes the records, and discusses the results. Also presented are early results of actual probe life testing now underway

  4. Five years of tritium handling experience at the Tritium Systems Test Assembly

    International Nuclear Information System (INIS)

    Carlson, R.V.

    1989-01-01

    The Tritium Systems Test Assembly (TSTA) at Los Alamos National Laboratory is a facility designed to develop and demonstrate, in full scale, technologies necessary for safe and efficient operation of tritium systems required for tokamak fusion reactors. TSTA currently consists of systems for evacuating reactor exhaust gas with compound cryopumps; for removing impurities from plasma exhaust gas and recovering the chemically-combined tritium; for separating the isotopes of hydrogen; for transfer pumping; or storage of hydrogen isotopes; for gas analysis; and for assuring safety by the necessary control, monitoring, and tritium removal from effluent streams. TSTA also has several small scale experiments to develop and test new equipment and processes necessary for fusion reactors. In this paper, data on component reliability, failure types and rates, and waste quantities are presented. TSTA has developed a Quality Assurance program for preparing and controlling the documentation of the procedures required for the design, purchase, and operation of the tritium systems. Operational experience under normal, abnormal, and emergency conditions is presented. One unique aspect of operations at TSTA is that the design personnel for the TSTA systems are also part of the operating personnel. This has allowed for the relatively smooth transition from design to operations. TSTA has been operated initially as a research facility. As the system is better defined, operations are proceeding toward production modes. The DOE requirements for the operation of a tritium facility like TSTA include personnel training, emergency preparedness, radiation protection, safety analysis, and preoperational appraisals. The integration of these requirements into TSTA operations is discussed. 4 refs., 3 figs., 3 tabs

  5. Quality Indicators for the Total Testing Process.

    Science.gov (United States)

    Plebani, Mario; Sciacovelli, Laura; Aita, Ada

    2017-03-01

    ISO 15189:2012 requires the use of quality indicators (QIs) to monitor and evaluate all steps of the total testing process, but several difficulties dissuade laboratories from effective and continuous use of QIs in routine practice. An International Federation of Clinical Chemistry and Laboratory Medicine working group addressed this problem and implemented a project to develop a model of QIs to be used in clinical laboratories worldwide to monitor and evaluate all steps of the total testing process, and decrease error rates and improve patient services in laboratory testing. All laboratories are invited, at no cost, to enroll in the project and contribute to harmonized management at the international level. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. A CAREM fuel assembly prototype construction in order to verify its mechanical design using hydrodynamic testing

    International Nuclear Information System (INIS)

    Aparicio, Gaspar; Di Marco, Agustin; Falcone, Jose M.; Giorgis, Miguel A.; Mathot, Sergio R.; Migliori, Julio; Orlando, Oscar S.; Restelli, Miguel A.; Ruggirello, Gabriel; Sapia, Gustavo C.; Zinzallari, Fausto; Bianchi, Daniel R.; Volpi, Ricardo M.

    2000-01-01

    The scope of this paper is to describe the activities of several Groups from three Atomic Centers (C. A. Bariloche, C. A. Ezeiza and C. A. Constituyentes), involved in the manufacturing of a CAREM fuel assembly prototype. The Design Group (UAIN-CAB) carried out the fuel assembly engineering. Cladding components were constructed by the Special Alloys Pilot Factory (UAMCN-CAE). Engineering Group (UACN-CAC) manufactured the parts to be processed, resorting to qualified suppliers. Elastic spacers were completely designed and constructed by this Group, and fuel rods, control rods, guide tubes and spacers were also welded here. Research Reactors Fuels Group (UACN-CAC) carried out the dimensional control of the elaborated parts, while Postirradiation Testing Group (UACN-CAC) performed the assembling of the fuel element. This paper also refers to the design and development of special equipment and devices, all of them required for the prototype construction. (author)

  7. Sampling analytical tests and destructive tests for quality assurance

    International Nuclear Information System (INIS)

    Saas, A.; Pasquini, S.; Jouan, A.; Angelis, de; Hreen Taywood, H.; Odoj, R.

    1990-01-01

    In the context of the third programme of the European Communities on the monitoring of radioactive waste, various methods have been developed for the performance of sampling and measuring tests on encapsulated waste of low and medium level activity, on the one hand, and of high level activity, on the other hand. The purpose was to provide better quality assurance for products to be stored on an interim or long-term basis. Various testing sampling means are proposed such as: - sampling of raw waste before conditioning and determination of the representative aliquot, - sampling of encapsulated waste on process output, - sampling of core specimens subjected to measurement before and after cutting. Equipment suitable for these sampling procedures have been developed and, in the case of core samples, a comparison of techniques has been made. The results are described for the various analytical tests carried out on the samples such as: - mechanical tests, - radiation resistance, - fire resistance, - lixiviation, - determination of free water, - biodegradation, - water resistance, - chemical and radiochemical analysis. Every time it was possible, these tests were compared with non-destructive tests on full-scale packages and some correlations are given. This word has made if possible to improve and clarify sample optimization, with fine sampling techniques and methodologies and draw up characterization procedures. It also provided an occasion for a first collaboration between the laboratories responsible for these studies and which will be furthered in the scope of the 1990-1994 programme

  8. FIELD TEST OF THE FLAME QUALITY INDICATOR

    Energy Technology Data Exchange (ETDEWEB)

    Rudin, Andrew M; Butcher, Thomas; Troost, Henry

    2003-02-04

    The flame quality indicator concept was developed at BNL specifically to monitor the brightness of the flame in a small oil burner and to provide a ''call for service'' notification when the brightness has changed from its setpoint, either high or low. In prior development work BNL has explored the response of this system to operational upsets such as excess air changes, fouled atomizer nozzles, poor fuel quality, etc. Insight Technologies, Inc. and Honeywell, Inc. have licensed this technology from the U.S. Department of Energy and have been cooperating to develop product offerings which meet industry needs with an optimal combination of function and price. Honeywell has recently completed the development of the Flame Quality Monitor (FQM or Honeywell QS7100F). This is a small module which connects via a serial cable to the burners primary operating control. Primary advantages of this approach are simplicity, cost, and ease of installation. Call-for-service conditions are output in the form of front panel indicator lights and contact closure which can trigger a range of external communication options. Under this project a field test was conducted of the FQM in cooperation with service organizations in Virginia, Pennsylvania, New Jersey, New York, and Connecticut. At total of 83 field sites were included. At each site the FQM was installed in parallel with another embodiment of this concept--the Insight AFQI. The AFQI incorporates a modem and provides the ability to provide detailed information on the trends in the flame quality over the course of the two year test period. The test site population was comprised of 79.5% boilers, 13.7% warm air furnaces, and 6.8% water heaters. Nearly all were of residential size--with firing rates ranging from 0.6 gallons of oil per hour to 1.25. During the course of the test program the monitoring equipment successfully identified problems including: plugged fuel lines, fouled nozzles, collapsed combustion

  9. The footwear factory's assembly sector: opposing organizational structure and quality from the ergonomic work analysis.

    Science.gov (United States)

    Silva, Kláudia M M N; Coelho, Bernardo G P; Junior, Josemir V S; Faria, Luiz F M; Dutra, Ludmila; Alvarenga, Marília; Roggini, Renan; Echternach, Eliza Helena de Oliveira

    2012-01-01

    Data from 2006 indicated that Brazilian footwear leather industry was composed of approximately 9,488 formally registered establishments, considering the leather industry, footwear and leather goods. It was responsible for 211,582 people employed. However, in spite of having many employees, this kind of organization found several problems when analyzed from the ergonomics view. With this premise, then, in order to identify bottlenecks and other engineering problems that could cause discomfort and motivation lack among workers, leading directly to the loss of the product quality, the assembly sector of women's shoes factory was characterized.

  10. Testing fruit quality by photoacoustic spectroscopy assay

    International Nuclear Information System (INIS)

    Popa, C; Dumitras, D C; Patachia, M; Banita, S

    2014-01-01

    This study was conducted with the aim of testing the hypothesis that raspberry and strawberry fruits from nonorganic farming release more ethylene gas compounds compared to organic ones. At the same time, the experiments focused on evaluation of the potential and capabilities of the laser photoacoustic spectroscopy (LPAS) method in the assessment of fruit quality related to the effects of nitrogen. Ethylene gas can be harmful and carcinogenic, because it can accelerate the natural ripening process of physiologically mature fruits and makes the fruits more consistent in size. With the advantages of LPAS, we demonstrate that the concentration of ethylene from nonorganic raspberry and strawberry fruits is greater than from organic ones. (paper)

  11. Tests of the RBMK-1500 reactor fuel assemblies in the Leningrad reactor

    International Nuclear Information System (INIS)

    Aden, V.C.; Varovin, I.A.; Vorontsov, B.A.

    1981-01-01

    Test of fuel assemblies of the RBMK-1500 reactor is conducted in the reactor of the Leningrad NPP unit 2 for proving the calculational values of critical power of the RBMK-1500 reactor fuel assemblies adopted in design. The experiment presupposes the maximal approximation of the fuel assembly operation parameters to the calculational critical parameters without bringing into the mode of heat transfer crisis. The experiments are carried out at 500, 850 and 900 MW(el) of the reactor. The maximal channel power made up 472 kW at 20.5 t/h coolant flow rate and 49% mass steam content at the outlet of the channel. It was concluded that there was supply up to the heat transfer crisis in all the investigated modes. Data of temperature measurings of the fuel element cans, readings of the devices of the failure control system of the fuel element cans and external inspection of the assemblies after the tests testify to it [ru

  12. Test Specifications and the Design of the Wire Wrapped 37-Pin Fuel Assembly for Hydrodynamic Experiments

    International Nuclear Information System (INIS)

    Chang, S. K.; Euh, D. J.; Bae, H.; Lee, H. Y.; Choi, S. R.

    2013-01-01

    Most influencing parameters on uncertainties and sensitivities of the CFD analyses are the friction coefficient and the mixing coefficient. The friction coefficient is related to the flow distribution in reactor sub-channels. The mixing coefficient is defined with the cross flow between neighboring sub-channels. The eventual purpose of the thermal hydraulic design considering these parameters is to guarantee the fuel cladding integrity as the design limit parameter. At the moment, the experimental program is being undertaken to quantify these friction and mixing parameters which characterize the flow distribution in sub-channels, and the wire wrapped 37-pin rod assembly and its hexagonal test rig have been designed and fabricated. The quantified thermal hydraulic experimental data from this program are utilized primarily to estimate the accuracy of the safety analysis codes and their thermal hydraulic model. A wire wrapped 37 pin fuel assembly has been designed for the measurements of the flow distribution, where the measurements are utilized to quantify the friction coefficient and the mixing coefficient. The test rig of the wire wrapped 37 pin fuel assembly has been fabricated considering the geometric and flow dynamic similarities. It comprises four components i. e., the upper plenum, the fuel housing, the lower plenum, and the wire wrapped 37 pin fuel assembly. At further works, the quantified friction and mixing coefficients through the experiments are going to be utilized for insuring the reliability of the CFD analysis results

  13. 7 CFR 58.642 - Quality control tests.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Quality control tests. 58.642 Section 58.642... Procedures § 58.642 Quality control tests. All mix ingredients shall be subject to inspection for quality and condition throughout each processing operation. Quality control tests shall be made on flow line samples as...

  14. 7 CFR 58.928 - Quality control tests.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Quality control tests. 58.928 Section 58.928... Procedures § 58.928 Quality control tests. All dairy products and other ingredients shall be subject to inspection for quality and condition throughout each processing operation. Quality control tests shall be...

  15. 7 CFR 58.335 - Quality control tests.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Quality control tests. 58.335 Section 58.335... Procedures § 58.335 Quality control tests. All milk, cream and related products are subject to inspection for quality and condition throughout each processing operation. Quality control tests shall be made on flow...

  16. Quality control tests for conventional mammography

    International Nuclear Information System (INIS)

    Dawod, Alnazer Ahmed Ibrahim

    2014-12-01

    Mammography is this the test that allows the radiologist to look at images of the inside of the breasts. Mammograms help detect breast cancer early successful treatment of breast cancer depends on that early diagnosis. Breast cancer is a very common condition. About one in every nine women develops breast cancer by the age of eighty. In addition to the clinical examination and self-examination, mammography plays important role in the detection of breast cancer before they become clinically visible tumors. The mammography is the most common test for early detection of breast cancer. Quality control techniques that done ensured importance of this programme to produce images with good diagnostic values and help radiologist to diagnose breast discase easily and avoid exposing patient to radiation hazards.(Author)

  17. Process and quality control in manufacturing of nuclear fuel assemblies of LWRs

    International Nuclear Information System (INIS)

    Dietrich, M.; Hoff, A.; Reimann, P.

    2000-01-01

    Manufacturing of nuclear fuel assemblies requires a multitude of different process and quality methods to assure and maintain a high quality level. In recent years methods have been applied which prevent deviations rather than detect deviant products. This paper gives an example on how to control a complex manufacturing process by using a small number of key parameters and second, it demonstrates the importance of graphical data evaluation and presentation methods. In the past many product and product characteristics were inspected m comparison with specification limits only. However, todays methods allow the early identification of trends, increase of variation, shifts disturbances etc. before the product characteristics exceed the specification limits. These methods are process control charts, x-y-plots, boxplots, failure mode and effect analysis (FMEA), process capability numbers and others. This paper demonstrates the beneficial use of some of the methods by presenting selected examples applied at Advanced Nuclear Fuels GmbH (ANF). (author)

  18. Assembly and Quality Control of the LHC Cryostats at CERN Motivations, Means, Results and Lessons Learnt

    CERN Document Server

    Poncet, A; Parma, V; Strubin, P; Tock, JP; Tommasini, D

    2007-01-01

    In 2001, the project management decided to perform at CERN the final assembly of the LHC superconducting magnets with cryostat parts and cold masses produced by European Industry in large series. This industrial-like production has required a very significant investment in tooling, production facilities, engineering and quality control efforts, in contractual partnership with a consortium of firms. This unusual endeavour of a limited lifetime represented more than 850,000 working hours spanning over five years, the work being done on a result-oriented basis by the contractor. This paper presents the reasons for having conducted this project at CERN, summarizes the work breakdown structure, the production means and methods, the infrastructure specially developed, the tooling, logistics and quality control aspects of the work performed and the results achieved, in analytical form. Finally, the lessons learnt are outlined.

  19. Combustion tests with different pellet qualities

    International Nuclear Information System (INIS)

    Bachs, A.; Dahlstroem, J.E.; Persson, Henrik; Tullin, C.

    1999-05-01

    Eight different pellet qualities with the diameters 6, 8 and 10 mm, from eight different producers has been tested in three pellet burners and two pellet stoves. The objective was to investigate how different diameter affect the emissions of CO, OGC and NO x . Previous experience has indicated that the pellet diameter could have significant importance for the combustion. This was not verified in the study. It showed contradictory that the diameter has a minor effect on the combustion result. The study shows that different combustion equipment give different emission. For e g hydrocarbon emissions the difference is a factor 2.2 between the 'best' and the 'worst' equipment fired on full load. The difference increases to 2.7 with lower load. The choice of fuel has a big importance for the quality of the combustion. For hydrocarbons the emissions could in an extreme situation differ with a factor 25 between 'best' and 'worst' fuel. More normally the difference is about a factor of five. Nitrogen oxide emissions are to a major part related to the nitrogen contents in the fuel. The difference between the 'best' and 'worst' fuel is in the range of a factor two. Tests with the same fuel in different equipment gives a variation of 20-30%. The combustion result depends on both the pellet quality and the equipment and there is no fuel that is good in all equipment. The big variation in combustion results shows that there is a big indifference between fuels used for small scale heating Project report from the program: Small scale combustion of biofuels. 2 refs, 15 figs, 5 tabs

  20. Tensile Test of Welding Joint Parts for a Plate-type Fuel Assembly

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, K. H.; Kim, J. Y.; Kim, H. J.; Yim, J. S. [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2013-05-15

    The tensile tests were performed using an INSTRON 4505 (universal tensile) testing machine. These welding joints are composed of two parts for the soundness of the fuel assembly; one is the side plate with a fixing bar and the other is a side plate with an end fitting. These two joint parts are fabricated by TIG welding method. The tensile tests of the welding joints of a plate-type FA are executed by a tensile test. The fixture configurations for the specimen are very important to obtain the strict test results. The maximum strength has an approximately linear correlation with the unit bonding length of the welding joints. In spite of these results, the maximum strengths of the welding joints are satisfied according to the minimum requirement. These tensile tests of the joint parts for a plate-type fuel assembly (FA) have to be executed to evaluate the structural strength. For the tensile test, the joint parts of a FA used in the test are made of aluminum alloy (Al6061-T6)

  1. Tensile Test of Welding Joint Parts for a Plate-type Fuel Assembly

    International Nuclear Information System (INIS)

    Yoon, K. H.; Kim, J. Y.; Kim, H. J.; Yim, J. S.

    2013-01-01

    The tensile tests were performed using an INSTRON 4505 (universal tensile) testing machine. These welding joints are composed of two parts for the soundness of the fuel assembly; one is the side plate with a fixing bar and the other is a side plate with an end fitting. These two joint parts are fabricated by TIG welding method. The tensile tests of the welding joints of a plate-type FA are executed by a tensile test. The fixture configurations for the specimen are very important to obtain the strict test results. The maximum strength has an approximately linear correlation with the unit bonding length of the welding joints. In spite of these results, the maximum strengths of the welding joints are satisfied according to the minimum requirement. These tensile tests of the joint parts for a plate-type fuel assembly (FA) have to be executed to evaluate the structural strength. For the tensile test, the joint parts of a FA used in the test are made of aluminum alloy (Al6061-T6)

  2. 7 CFR 58.733 - Quality control tests.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Quality control tests. 58.733 Section 58.733... Procedures § 58.733 Quality control tests. (a) Chemical analyses. The following chemical analyses shall be... pasteurization by means of the phosphatase test, as well as any other tests necessary to assure good quality...

  3. Development of techniques for joining fuel rod simulators to test assemblies

    International Nuclear Information System (INIS)

    Moorhead, A.J.; Reed, R.W.

    1980-01-01

    A unique tubular electrode carrier is described for gas tungsten-arc welding small-diameter nuclear fuel rod simulators to the tubesheet of a test assembly. Both the close-packed geometry of the array of simulators and the extension of coaxial electrical conductors from each simulator hindered access to the weld joint. Consequently, a conventional gas tungsten-arc torch could not be used. Two seven-rod assemblies that were mockups of the simulator-to-tubesheet joint area were welded and successfully tested. Modified versions of the electrode carrier for brazing electrical leads to the upper ends of the fuel pin simulators are also described. Satisfactory brazes have been made on both single-rod mockups and an array of 25 simulators by using the modified electrode carrier and a filler metal with a composition of 71.5 Ag-28 Cu-0.5 Ni

  4. Testing and assembly of the detectors for the Millimeter Bolometer Array Camera on ACT

    International Nuclear Information System (INIS)

    Marriage, T.A.; Chervenak, J.A.; Doriese, W.B.

    2006-01-01

    The Millimeter Bolometer Array Camera (MBAC) for the Atacama Cosmology Telescope consists of three Transition Edge Sensor (TES) arrays to make simultaneous observations of the Cosmic Microwave Background in three frequency bands. MBAC TESs are NASA Goddard Pop-Up Detectors (PUD) which are read-out by NIST time-domain multiplexers. MBAC is constructed by stacking 1x32 TES columns to form the 32x32 element arrays. The arrays are modular (connectorized) at the 1x32 column level such that array assembly is reversible and camera repair possible. Prior to assembly, each column is tested in a quick (2h) cycling 4 He/ 3 He adsorption refrigerator. Tests include measurements of TES current-voltage curves and TES complex impedance

  5. Testing and assembly of the detectors for the Millimeter Bolometer Array Camera on ACT

    Energy Technology Data Exchange (ETDEWEB)

    Marriage, T.A. [Physics Department, Princeton University, Washington Road, Princeton, NJ 08544 (United States)]. E-mail: marriage@princeton.edu; Chervenak, J.A. [NASA Goddard Space Flight Center, Greenbelt, MD 20771 (United States); Doriese, W.B. [National Institute of Standards, 325 Broadway, Boulder, CO 80305 (United States)

    2006-04-15

    The Millimeter Bolometer Array Camera (MBAC) for the Atacama Cosmology Telescope consists of three Transition Edge Sensor (TES) arrays to make simultaneous observations of the Cosmic Microwave Background in three frequency bands. MBAC TESs are NASA Goddard Pop-Up Detectors (PUD) which are read-out by NIST time-domain multiplexers. MBAC is constructed by stacking 1x32 TES columns to form the 32x32 element arrays. The arrays are modular (connectorized) at the 1x32 column level such that array assembly is reversible and camera repair possible. Prior to assembly, each column is tested in a quick (2h) cycling {sup 4}He/{sup 3}He adsorption refrigerator. Tests include measurements of TES current-voltage curves and TES complex impedance.

  6. A thermal-hydraulic test rig for advanced fast reactor fuel assemblies

    International Nuclear Information System (INIS)

    Rapier, A.C.

    1989-03-01

    A new design of fast reactor fuel assemblies has been proposed in which the pins are supported in grids attached to the wrapper by flexible skirts. Coolant mixing is enhanced by the skirts diverting flow into the cluster of pins at each grid. There are insufficient empirical data available for the detailed design of the skirt or for the input to computer calculations of flow and heat transfer. A test rig to provide these data has been designed and built. (author)

  7. Data base for failure/maintenance at the Tritium Systems Test Assembly

    International Nuclear Information System (INIS)

    Gruetzmacher, K.M.; Wilhelm, R.C.

    1986-01-01

    A data collection system for obtaining availability/reliability data on fusion technology has been installed at the Tritium Systems Test Assembly (TSTA) of Los Alamos National Laboratory. The system is fashioned after the Centralized Reliability Data Organization developed at Oak Ridge National Laboratory. The data collection system is currently being used at TSTA and is working well. The amount of data that has been collected at TSTA to date is not sufficient to indicate meaningful trends in availability analysis

  8. Design and test of a 2.25-MW transformer rectifier assembly

    Science.gov (United States)

    Cormier, R.; Daeges, J.

    1989-01-01

    A new 2.25-MW transformer rectifier assembly was fabricated for DSS-13 at Goldstone, California. The transformer rectifier will provide constant output power of 2.25 MW at any voltage from 31 kV to 125 kV. This will give a new capability of 1 MW of RF power at X-band, provided appropriate microwave tubes are in the power amplifier. A description of the design and test results is presented.

  9. Report on the evaluation of the tritium producing burnable absorber rod lead test assembly. Revision 1

    International Nuclear Information System (INIS)

    1997-03-01

    This report describes the design and fabrication requirements for a tritium-producing burnable absorber rod lead test assembly and evaluates the safety issues associated with tritium-producing burnable absorber rod irradiation on the operation of a commercial light water reactor. The report provides an evaluation of the tritium-producing burnable absorber rod design and concludes that irradiation can be performed within U.S. Nuclear Regulatory Commission regulations applicable to a commercial pressurized light water reactor

  10. Quality assurance during preoperational testing and during startup operation

    International Nuclear Information System (INIS)

    Eisele, H.; Meyer, F.A.

    1980-01-01

    Rules and guidelines for the quality assurance. Quality assurance in the course of preoperational testing and the startup period: preoperational testing; hot functional test I; hot functional test II; initial making critical and zero power physics testing; power range testing. Startup documents: startup program; startup instructions; startup data sheet; startup sequence outlines; final startup reports. Advisory safety committee for nuclear startup. (orig./RW)

  11. Endurance test for IR rig for RI production assembly (test procedure)

    International Nuclear Information System (INIS)

    Chung, Heung June; Ryu, Jeong Soo

    2000-08-01

    This test procedure details the test loop, test method, and test procedure for pressure drop, vibration and endurance test of IR Rig for RI production. From the pressure drop test, the hydraulic design requirements of the capsule are verified. HANARO limit condition is checked and the compatibility with HANARO core is verified. From flow induced vibration test vibration frequency and displacement are investigated. The wear of IR Rig is investigated through endurance test, and these data are used to evaluate the expected wear at maximum resident time of the IR Rig for RI production

  12. Implementation of a quality assurance system for the design and manufacturing of fuel assembly MTR-plate type

    International Nuclear Information System (INIS)

    Koll, J.H.

    1987-01-01

    Since more than 30 years ago, fuel assemblies (FA) of the MTR-Plate type, for research reactors, have been developed and produced using well known technologies, with different methods for the design, manufacturing, quality control and subsequent verification of FA behaviour, as well as of the design data. The FA and its reliability has been improved through the recycling of the obtained information. No nuclear accidents or major incidents have taken place that can be blamed to FA due to design, manufacturing or its use. Since the 70's, the use of Quality Assurance methodology has been increased, especially for Nuclear Power Plants, in order to ensure safety for these reactors. The use of QA for reactors for research, testing or other uses, has also been steadily increased, not only due to safety reasons, but also because of its convenience for a good operation, being presently a common requirement of the operator of the installation. Herewith is described the way the QA system that has been developed for the design, manufacturing, quality control and supply of MTR-plate type FA, at the Development Section of the Argentine Atomic Energy Commission (CNEA). (Author)

  13. Cytosolic chaperones mediate quality control of higher-order septin assembly in budding yeast.

    Science.gov (United States)

    Johnson, Courtney R; Weems, Andrew D; Brewer, Jennifer M; Thorner, Jeremy; McMurray, Michael A

    2015-04-01

    Septin hetero-oligomers polymerize into cytoskeletal filaments with essential functions in many eukaryotic cell types. Mutations within the oligomerization interface that encompasses the GTP-binding pocket of a septin (its "G interface") cause thermoinstability of yeast septin hetero-oligomer assembly, and human disease. When coexpressed with its wild-type counterpart, a G interface mutant is excluded from septin filaments, even at moderate temperatures. We show that this quality control mechanism is specific to G interface mutants, operates during de novo septin hetero-oligomer assembly, and requires specific cytosolic chaperones. Chaperone overexpression lowers the temperature permissive for proliferation of cells expressing a G interface mutant as the sole source of a given septin. Mutations that perturb the septin G interface retard release from these chaperones, imposing a kinetic delay on the availability of nascent septin molecules for higher-order assembly. Un-expectedly, the disaggregase Hsp104 contributes to this delay in a manner that does not require its "unfoldase" activity, indicating a latent "holdase" activity toward mutant septins. These findings provide new roles for chaperone-mediated kinetic partitioning of non-native proteins and may help explain the etiology of septin-linked human diseases. © 2015 Johnson et al. This article is distributed by The American Society for Cell Biology under license from the author(s). Two months after publication it is available to the public under an Attribution–Noncommercial–Share Alike 3.0 Unported Creative Commons License (http://creativecommons.org/licenses/by-nc-sa/3.0).

  14. Engineering design and analysis of an ITER-like first mirror test assembly on JET

    DEFF Research Database (Denmark)

    Vizvary, Z.; Bourdel, B.; Garcia-Carrasco, A.

    2017-01-01

    is underway on JET, under contract to ITER, with primary objective to test if, under realistic plasma and wall material conditions and with ITER-like first mirror aperture geometry, deposits do grow on first mirrors. This paper describes the engineering design and analysis of this mirror test assembly......The ITER first mirrors are the components of optical diagnostic systems closest to the plasma. Deposition may build up on the surfaces of the mirror affecting their ability to fulfil their function. However, physics modelling of this layer growth is fraught with uncertainty. A new experiment...

  15. Forced-convection boiling tests performed in parallel simulated LMR fuel assemblies

    International Nuclear Information System (INIS)

    Rose, S.D.; Carbajo, J.J.; Levin, A.E.; Lloyd, D.B.; Montgomery, B.H.; Wantland, J.L.

    1985-01-01

    Forced-convection tests have been carried out using parallel simulated Liquid Metal Reactor fuel assemblies in an engineering-scale sodium loop, the Thermal-Hydraulic Out-of-Reactor Safety facility. The tests, performed under single- and two-phase conditions, have shown that for low forced-convection flow there is significant flow augmentation by thermal convection, an important phenomenon under degraded shutdown heat removal conditions in an LMR. The power and flows required for boiling and dryout to occur are much higher than decay heat levels. The experimental evidence supports analytical results that heat removal from an LMR is possible with a degraded shutdown heat removal system

  16. Modeling and simulation for microelectronic packaging assembly manufacturing, reliability and testing

    CERN Document Server

    Liu, Sheng

    2011-01-01

    Although there is increasing need for modeling and simulation in the IC package design phase, most assembly processes and various reliability tests are still based on the time consuming ""test and try out"" method to obtain the best solution. Modeling and simulation can easily ensure virtual Design of Experiments (DoE) to achieve the optimal solution. This has greatly reduced the cost and production time, especially for new product development. Using modeling and simulation will become increasingly necessary for future advances in 3D package development.  In this book, Liu and Liu allow people

  17. Lead test assembly irradiation and analysis Watts Bar Nuclear Plant, Tennessee and Hanford Site, Richland, Washington

    International Nuclear Information System (INIS)

    1997-07-01

    The U.S. Department of Energy (DOE) needs to confirm the viability of using a commercial light water reactor (CLWR) as a potential source for maintaining the nation's supply of tritium. The Proposed Action discussed in this environmental assessment is a limited scale confirmatory test that would provide DOE with information needed to assess that option. This document contains the environmental assessment results for the Lead test assembly irradiation and analysis for the Watts Bar Nuclear Plant, Tennessee, and the Hanford Site in Richland, Washington

  18. Neutron data testing for plutonium isotopes in experiments at fast critical assemblies

    International Nuclear Information System (INIS)

    Bednyakov, S.M.; Dulin, V.A.; Manturov, G.N.; Mozhaev, V.K.; Semenov, M.Yu.; Tsibulya, A.M.

    1996-01-01

    Experimental results on checking neutron data, obtained at the fast critical assemblies, are presented. They constitute sufficiently large collection of data making it possible to test nuclear neutron constants of plutonium isotopes for the new system of group constants BNAB-93. The work contains comparison of the measurement results on average fission cross section ratios and reactivity coefficients ratios for 239,240,241 Pu (to 235 U) with calculational data, obtained on the basis of the new testing system of the BNAB-93 group constants system. 14 refs., 6 figs

  19. The in-pile proving test for fuel assembly of Qinshan nuclear power plant

    International Nuclear Information System (INIS)

    Chen Dianshan; Zhang Shucheng; Kang Rixin; Wang Huarong; Chen Guanghan

    1989-10-01

    The in-pile proving test for fuel assembly of Qinshan nuclear power plant had been conducted in the experimental loop of HWRR at IAE (Institute of Atomic Energy) in Beijing, China, from January 1985 to December 1986. Average burnup of 27000 MWd/tU and peak burnup of 34000 MWd/tU of fuel rod had already been reached. The basic status of the experiment are described, emphasis is placed on the discussion of proving test parameters and analysis of experiment results

  20. Fuel cleanup system for the tritium systems test assembly: design and experiments

    International Nuclear Information System (INIS)

    Kerr, E.C.; Bartlit, J.R.; Sherman, R.H.

    1980-01-01

    A major subsystem of the Tritium Systems Test Assembly is the Fuel Cleanup System (FCU) whose functons are to: (1) remove impurities in the form of argon and tritiated methane, water, and ammonia from the reactor exhaust stream and (2) recover tritium for reuse from the tritiated impurities. To do this, a hybrid cleanup system has been designed which utilizes and will test concurrently two differing technologies - one based on disposable, hot metal (U and Ti) getter beds and a second based on regenerable cryogenic asdorption beds followed by catalytic oxidation of impurities to DTO and stackable gases and freezout of the resultant DTO to recover essentially all tritium for reuse

  1. Design, development, and testing of the DCT Cassegrain instrument support assembly

    Science.gov (United States)

    Bida, Thomas A.; Dunham, Edward W.; Nye, Ralph A.; Chylek, Tomas; Oliver, Richard C.

    2012-09-01

    The 4.3m Discovery Channel Telescope delivers an f/6.1 unvignetted 0.5° field to its RC focal plane. In order to support guiding, wavefront sensing, and instrument installations, a Cassegrain instrument support assembly has been developed which includes a facility guider and wavefront sensor package (GWAVES) and multiple interfaces for instrumentation. A 2-element, all-spherical, fused-silica corrector compensates for field curvature and astigmatism over the 0.5° FOV, while reducing ghost pupil reflections to minimal levels. Dual roving GWAVES camera probes pick off stars in the outer annulus of the corrected field, providing simultaneous guiding and wavefront sensing for telescope operations. The instrument cube supports 5 co-mounted instruments with rapid feed selection via deployable fold mirrors. The corrected beam passes through a dual filter wheel before imaging with the 6K x 6K single CCD of the Large Monolithic Imager (LMI). We describe key development strategies for the DCT Cassegrain instrument assembly and GWAVES, including construction of a prime focus test assembly with wavefront sensor utilized in fall 2011 to begin characterization of the DCT primary mirror support. We also report on 2012 on-sky test results of wavefront sensing, guiding, and imaging with the integrated Cassegrain cube.

  2. Pendulum support of the W7-X plasma vessel: Design, tests, manufacturing, assembly, critical aspects, status

    Energy Technology Data Exchange (ETDEWEB)

    Missal, B., E-mail: bernd.missal@ipp.mpg.de [Max-Planck-Institut für Plasmaphysik, EURATOM Association, Teilinstitut Greifswald, Wendelsteinstraße 1, D-17491 Greifswald (Germany); Leher, F.; Schiller, T. [MAN Diesel and Turbo SE, Werftstraße 17, 94469 Deggendorf (Germany); Friedrich, P. [Universität Rostock, FB Maschinenbau und Schiffstechnik, Albert-Einsteins-Straße 2, 18051 Rostock (Germany); Capriccioli, A. [ENEA Frascati, Fusion Technology Unit, Frascati (Italy)

    2014-10-15

    Highlights: • Plasma vessel support has to allow vertical adjustment and horizontal passive movement. • Planar sliding tables with PTFE do not fulfill all requirements. • Pendulums can fulfill all requirements. • Geometry and material of spherical bearings had to be optimized in calculations and tests. • Optimized pendulums were manufactured and assembled. - Abstract: The superconducting helical advanced stellarator Wendelstein 7-X (W7-X) is under construction at the Max-Planck-Institut für Plasmaphysik (IPP) in Greifswald, Germany. The three dimensional shape of plasma will be generated by 50 non-planar magnetic coils. The plasma vessel geometry follows exactly this three dimensional shape of plasma. To ensure the superconductivity of coils a cryo vacuum has to be generated. Therefore the coils and their support structure are enclosed within the outer vessel. Plasma vessel, coil structures and outer vessel have to be supported separately. This paper will describe the vertical supports of plasma vessel which have to fulfill two special requirements, vertical adjustability and horizontal mobility. These two tasks will be carried out by plasma vessel supports (PVS) with hydraulic cylinders, special sliding tables during assembly and pendulum supports during operating phase. The paper will give an overview of design, calculation, tests, fabrication, assembly, critical aspects and status of PVS.

  3. Numerical design and test on an assembled structure of a bolted joint with viscoelastic damping

    Science.gov (United States)

    Hammami, Chaima; Balmes, Etienne; Guskov, Mikhail

    2016-03-01

    Mechanical assemblies are subjected to many dynamic loads and modifications are often needed to achieve acceptable vibration levels. While modifications on mass and stiffness are well mastered, damping modifications are still considered difficult to design. The paper presents a case study on the design of a bolted connection containing a viscoelastic damping layer. The notion of junction coupling level is introduced to ensure that sufficient energy is present in the joints to allow damping. Static performance is then addressed and it is shown that localization of metallic contact can be used to meet objectives, while allowing the presence of viscoelastic materials. Numerical prediction of damping then illustrates difficulties in optimizing for robustness. Modal test results of three configurations of an assembled structure, inspired by aeronautic fuselages, are then compared to analyze the performance of the design. While validity of the approach is confirmed, the effect of geometric imperfections is shown and stresses the need for robust design.

  4. Digital test assembly of truck parts with the IMMA-tool--an illustrative case.

    Science.gov (United States)

    Hanson, L; Högberg, D; Söderholm, M

    2012-01-01

    Several digital human modelling (DHM) tools have been developed for simulation and visualisation of human postures and motions. In 2010 the DHM tool IMMA (Intelligently Moving Manikins) was introduced as a DHM tool that uses advanced path planning techniques to generate collision free and biomechanically acceptable motions for digital human models (as well as parts) in complex assembly situations. The aim of the paper is to illustrate how the IPS/IMMA tool is used at Scania CV AB in a digital test assembly process, and to compare the tool with other DHM tools on the market. The illustrated case of using the IMMA tool, here combined with the path planner tool IPS, indicates that the tool is promising. The major strengths of the tool are its user friendly interface, the motion generation algorithms, the batch simulation of manikins and the ergonomics assessment methods that consider time.

  5. Thermal-hydraulic analysis of PWR small assembly for irradiation test of CARR

    International Nuclear Information System (INIS)

    Yin Hao; Zou Yao; Liu Xingmin

    2015-01-01

    The thermal-hydraulic behaviors of the PWR 4 × 4 small assembly tested in the high temperature and high pressure loop of China Advanced Research Reactor were analyzed. The CFD method was used to carry out 3D simulation of the model, thus detailed thermal-hydraulic parameters were obtained. Firstly, the simplified model was simulated to give the 3D temperature and velocity distributions and analyze the heat transfer process. Then the whole scale small assembly model was simulated and the simulation results were compared with those of simplified rod bundle model. Its flow behavior was studied and flow mixing characteristics of the grids were analyzed, and the mixing factor of the grid was calculated and can be used for further thermal-hydraulic study. It is shown that the highest temperature of the fuel rod meets the design limit and the mixing effect of the grid is obvious. (authors)

  6. 7 CFR 58.523 - Laboratory and quality control tests.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Laboratory and quality control tests. 58.523 Section... Service 1 Operations and Operating Procedures § 58.523 Laboratory and quality control tests. (a) Quality control tests shall be made on samples as often as necessary to determine the shelf-life and stability of...

  7. Formation of high-quality self-assembled monolayers of conjugated dithiols on gold: base matters.

    Science.gov (United States)

    Valkenier, Hennie; Huisman, Everardus H; van Hal, Paul A; de Leeuw, Dago M; Chiechi, Ryan C; Hummelen, Jan C

    2011-04-06

    This Article reports a systematic study on the formation of self-assembled monolayers (SAMs) of conjugated molecules for molecular electronic (ME) devices. We monitored the deprotection reaction of acetyl protected dithiols of oligophenylene ethynylenes (OPEs) in solution using two different bases and studied the quality of the resulting SAMs on gold. We found that the optimal conditions to reproducibly form dense, high-quality monolayers are 9-15% triethylamine (Et(3)N) in THF. The deprotection base tetrabutylammonium hydroxide (Bu(4)NOH) leads to less dense SAMs and the incorporation of Bu(4)N into the monolayer. Furthermore, our results show the importance of the equilibrium concentrations of (di)thiolate in solution on the quality of the SAM. To demonstrate the relevance of these results for molecular electronics applications, large-area molecular junctions were fabricated using no base, Et(3)N, and Bu(4)NOH. The magnitude of the current-densities in these devices is highly dependent on the base. A value of β=0.15 Å(-1) for the exponential decay of the current-density of OPEs of varying length formed using Et(3)N was obtained. © 2011 American Chemical Society

  8. Testing Whether Defective Chromatin Assembly in S-Phase Contributes to Breast Cancer

    National Research Council Canada - National Science Library

    Adams, Peter

    2003-01-01

    .... We used a dominant negative mutant of (chromatin assembly factor-I) CAF1, a complex that assembles newly synthesized DNA into nucleosomes, to inhibit S-phase chromatin assembly and found that this induced S-phase arrest...

  9. Testing Whether Defective Chromatin Assembly in S-Phase Contributes to Breast Cancer

    National Research Council Canada - National Science Library

    Adams, Peter

    2004-01-01

    .... We used a dominant negative mutant of (chromatin assembly factor-I) CAF1, a complex that assembles newly synthesized DNA into nucleosomes, to inhibit S-phase chromatin assembly and found that this induced S-phase arrest...

  10. Manufacturing, assembly and tests of SPIDER Vacuum Vessel to develop and test a prototype of ITER neutral beam ion source

    Energy Technology Data Exchange (ETDEWEB)

    Zaccaria, Pierluigi, E-mail: pierluigi.zaccaria@igi.cnr.it [Consorzio RFX (CNR, ENEA, INFN, Università di Padova, Acciaierie Venete S.p.A.), Padova (Italy); Valente, Matteo; Rigato, Wladi; Dal Bello, Samuele; Marcuzzi, Diego; Agostini, Fabio Degli; Rossetto, Federico; Tollin, Marco [Consorzio RFX (CNR, ENEA, INFN, Università di Padova, Acciaierie Venete S.p.A.), Padova (Italy); Masiello, Antonio [Fusion for Energy F4E, Barcelona (Spain); Corniani, Giorgio; Badalocchi, Matteo; Bettero, Riccardo; Rizzetto, Dario [Ettore Zanon S.p.A., Schio (VI) (Italy)

    2015-10-15

    Highlights: • The SPIDER experiment aims to qualify and optimize the ion source for ITER injectors. • The large SPIDER Vacuum Vessel was built and it is under testing at the supplier. • The main working and assembly steps for production are presented in the paper. - Abstract: The SPIDER experiment (Source for the Production of Ions of Deuterium Extracted from an RF plasma) aims to qualify and optimize the full size prototype of the negative ion source foreseen for MITICA (full size ITER injector prototype) and the ITER Heating and Current Drive Injectors. Both SPIDER and MITICA experiments are presently under construction at Consorzio RFX in Padova (I), with the financial support from IO (ITER Organization), Fusion for Energy, Italian research institutions and contributions from Japan and India Domestic Agencies. The vacuum vessel hosting the SPIDER in-vessel components (Beam Source and calorimeters) has been manufactured, assembled and tested during the last two years 2013–2014. The cylindrical vessel, about 6 m long and 4 m in diameter, is composed of two cylindrical modules and two torispherical lids at the ends. All the parts are made by AISI 304 L stainless steel. The possibility of opening/closing the vessel for monitoring, maintenance or modifications of internal components is guaranteed by bolted junctions and suitable movable support structures running on rails fixed to the building floor. A large number of ports, about one hundred, are present on the vessel walls for diagnostic and service purposes. The main working steps for construction and specific technological issues encountered and solved for production are presented in the paper. Assembly sequences and tests on site are furthermore described in detail, highlighting all the criteria and requirements for correct positioning and testing of performances.

  11. Manufacturing, assembly and tests of SPIDER Vacuum Vessel to develop and test a prototype of ITER neutral beam ion source

    International Nuclear Information System (INIS)

    Zaccaria, Pierluigi; Valente, Matteo; Rigato, Wladi; Dal Bello, Samuele; Marcuzzi, Diego; Agostini, Fabio Degli; Rossetto, Federico; Tollin, Marco; Masiello, Antonio; Corniani, Giorgio; Badalocchi, Matteo; Bettero, Riccardo; Rizzetto, Dario

    2015-01-01

    Highlights: • The SPIDER experiment aims to qualify and optimize the ion source for ITER injectors. • The large SPIDER Vacuum Vessel was built and it is under testing at the supplier. • The main working and assembly steps for production are presented in the paper. - Abstract: The SPIDER experiment (Source for the Production of Ions of Deuterium Extracted from an RF plasma) aims to qualify and optimize the full size prototype of the negative ion source foreseen for MITICA (full size ITER injector prototype) and the ITER Heating and Current Drive Injectors. Both SPIDER and MITICA experiments are presently under construction at Consorzio RFX in Padova (I), with the financial support from IO (ITER Organization), Fusion for Energy, Italian research institutions and contributions from Japan and India Domestic Agencies. The vacuum vessel hosting the SPIDER in-vessel components (Beam Source and calorimeters) has been manufactured, assembled and tested during the last two years 2013–2014. The cylindrical vessel, about 6 m long and 4 m in diameter, is composed of two cylindrical modules and two torispherical lids at the ends. All the parts are made by AISI 304 L stainless steel. The possibility of opening/closing the vessel for monitoring, maintenance or modifications of internal components is guaranteed by bolted junctions and suitable movable support structures running on rails fixed to the building floor. A large number of ports, about one hundred, are present on the vessel walls for diagnostic and service purposes. The main working steps for construction and specific technological issues encountered and solved for production are presented in the paper. Assembly sequences and tests on site are furthermore described in detail, highlighting all the criteria and requirements for correct positioning and testing of performances.

  12. Quality Assurance and Functionality Tests on Electrical Components during the ATLAS IBL Production

    CERN Document Server

    Bassalat, A; The ATLAS collaboration

    2014-01-01

    During the shutdown of 2013-2014, for the enhancement of the current ATLAS Pixel Detector, a fourth layer (Insertable B Layer, IBL) is being built and will be installed between the innermost layer and a new beam pipe. A new generation of readout chip has been developed, and two different sensor designs, a rather conventional planar and a 3D design, have been bump bonded to the Front Ends. Additionally, new staves and module flex circuits have been developed. A production QA test bench was therefore established to test all production staves before integration with the new beam pipe. Quality assurance measurements under cleanroom conditions, including temperature and humidity control, are being performed on the individual components during the various production steps of the IBL; namely, connectivity tests, electrical tests and signal probing on individual parts and assembled subsystems. This paper discusses the pre-assembly QC procedures, the capabilities of the stave qualification setup, and recent results fr...

  13. Aqueous corrosion in static capsule tests representing multi-metal assemblies in the hydraulic circuit of Tore Supra

    Energy Technology Data Exchange (ETDEWEB)

    Lipa, M. [Association Euratom-CEA, CEA/DSM/DRFC, Centre de Cadarache, 13108 Saint-Paul-Lez-Durance (France)], E-mail: manfred.lipa@cea.fr; Blanchet, J.; Feron, D. [CEA/DEN/SCCME, Centre de Saclay, 91191 Gif sur Yvette (France); Cellier, F. [AREVA ANP, Centre Technique, 71380 Saint Marcel (France)

    2008-12-15

    Tore supra (TS) in vessel components represent a unique combination of metals in the hydraulic circuit. Different materials, e.g. stainless steel, copper alloys, nickel, etc., were joined together by fusion welding, brazing and friction. Since the operation and baking temperature of all in vessel components has been defined to be set at 230 deg. C/40 bars a special water chemistry of the cooling water loop was suggested in order to prevent eventual water leaks due to corrosion at relative high temperatures and pressures in tubes, bellows, coils and coolant plant ancillary equipments. Following experiences with water chemistry in Pressurised Water Reactors, an all volatile chemical treatment (AVT) has been defined for the cooling water quality of TS. Since then, a simplified static (no fluid circulation) corrosion test program at relatively high temperature and pressure has been performed using capsule-type samples made of above mentioned multi-metal assemblies.

  14. Adaptive testing for video quality assessment

    NARCIS (Netherlands)

    Menkovski, V.; Exarchakos, G.; Liotta, A.; Damásio, M.J.; Cardoso, G.; Quico, C.; Geerts, D.

    2011-01-01

    Optimizing the Quality of Experience and avoiding under or over provisioning in video delivery services requires understanding of how different resources affect the perceived quality. The utility of resources, such as bit-rate, is directly calculated by proportioningthe improvement in quality over

  15. Endurance of lead-free assembly under board level drop test and thermal cycling

    Energy Technology Data Exchange (ETDEWEB)

    Xia Yanghua [State Key Laboratory of Functional Materials for Informatics, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai 200050 (China)], E-mail: xia_yanghua@hotmail.com; Xie Xiaoming [State Key Laboratory of Functional Materials for Informatics, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai 200050 (China)

    2008-06-12

    The reliability of lead-free electronic assemblies under board level drop test and thermal cycling was investigated. TSOP (thin small outline package) devices with FeNi leads were reflow soldered on FR4 PCB (printed circuit board) with Sn3.0Ag0.5Cu (wt%) solder. The effects of different PCB finishes (organic solderability preservative (OSP) and electroless nickel immersion gold (ENIG)) on the reliability performance were studied. The results show that the assemblies with ENIG finishes reveal better reliability performance than its OSP counterparts under drop test, however, the OSP samples outperform those with ENIG finishes under thermal cycling. The failure mechanism is different under these two test conditions: the solder joints fracture into the intermetallic compounds (IMCs) layer under drop test, and cracks initiate in the bulk solder under thermal cycling. The surface finishes have an effect on the failure mode. The propagation of crack in the ENIG case is along the device/solder interface, while in the case of OSP, the crack extends parallel to the solder/PCB interface.

  16. Vibration test report for in-chimney bracket and instrumented fuel assembly

    Energy Technology Data Exchange (ETDEWEB)

    Ryu, Jeong Soo; Yoon, D. B.; Cho, Y. G.; Ahn, G. H.; Lee, J. H.; Park, J.H

    2000-10-01

    The vibration levels of in-chimney bracket structure which is installed in reactor chimney and instrumented fuel assembly(Type-B Bundle) are investigated under the steady state normal operating condition of the reactor. For this purpose, 4 acceleration data on the guide tube of the instrumented fuel assembly and in-chimney bracket structures subjected to fluid induced vibration are measured. For the analysis of the vibration data, vibration analysis program which can perform basic time and frequency domain analysis, is prepared, and its reliability is verified by comparing the analysis results with those of commercial analysis program(I-DEAS). In time domain analysis, maximum amplitudes, and RMS values of accelerations and displacements from the measured vibration signal, are obtained. The frequency components of the vibration data are analyzed by using the frequency domain analysis. These analysis results show that the levels of the measured vibrations are within the allowable level, and the low frequency component near 10 Hz is dominant in the vibration signal. For the evaluation of the structural integrity on the in-chimney bracket and related structures including the instrumented fuel assembly, the static analysis for ANSYS finite element model is carried out. These analysis results show that the maximum stresses are within the allowable stresses of the ASME code, and the maximum displacement of the top of the flow tube is within the displacement limit. Therefore any damage on the structural integrity is not expected when the irradiation test is performed using the in-chimney bracket.

  17. Vibration test report for in-chimney bracket and instrumented fuel assembly

    International Nuclear Information System (INIS)

    Ryu, Jeong Soo; Yoon, D. B.; Cho, Y. G.; Ahn, G. H.; Lee, J. H.; Park, J.H.

    2000-10-01

    The vibration levels of in-chimney bracket structure which is installed in reactor chimney and instrumented fuel assembly(Type-B Bundle) are investigated under the steady state normal operating condition of the reactor. For this purpose, 4 acceleration data on the guide tube of the instrumented fuel assembly and in-chimney bracket structures subjected to fluid induced vibration are measured. For the analysis of the vibration data, vibration analysis program which can perform basic time and frequency domain analysis, is prepared, and its reliability is verified by comparing the analysis results with those of commercial analysis program(I-DEAS). In time domain analysis, maximum amplitudes, and RMS values of accelerations and displacements from the measured vibration signal, are obtained. The frequency components of the vibration data are analyzed by using the frequency domain analysis. These analysis results show that the levels of the measured vibrations are within the allowable level, and the low frequency component near 10 Hz is dominant in the vibration signal. For the evaluation of the structural integrity on the in-chimney bracket and related structures including the instrumented fuel assembly, the static analysis for ANSYS finite element model is carried out. These analysis results show that the maximum stresses are within the allowable stresses of the ASME code, and the maximum displacement of the top of the flow tube is within the displacement limit. Therefore any damage on the structural integrity is not expected when the irradiation test is performed using the in-chimney bracket

  18. Benchmark physics tests in the metallic-fuelled assembly ZPPR-15

    International Nuclear Information System (INIS)

    McFarlane, H.F.; Brumbach, S.B.; Carpenter, S.G.; Collins, P.J.

    1987-01-01

    Results of the first benchmark physics tests of a metallic-fueled, demonstration-size, liquid metal reactor are reported. A simple, two-zone, cylindrical conventional assembly was built with three distinctly different compositions to represent the stages of the Integral Fast Reactor fuel cycle. Experiments included criticality, control, power distribution, reaction rate ratios, reactivity coefficients, shielding, kinetics and spectrum. Analysis was done with 3-D nodal diffusion calculations and ENDFIB-V.2 cross sections. Predictions of the ZPPR-15 reactor physics parameters agreed sufficiently well with the measured values to justify confidence in design analyses for metallic-fueled LMRs

  19. Benchmark physics tests in the metallic-fueled assembly ZPPR-15

    International Nuclear Information System (INIS)

    McFarlane, H.F.; Brumbach, S.B.; Carpenter, S.G.; Collins, P.J.

    1989-01-01

    Results of the first benchmark physics tests of a metallic-fueled, demonstration-size liquid-metal reactor (LMR) are reported. A simple, two-zone, cylindrical conventional assembly was built with three distinctly different compositions to represent the stages of the Integral Fast Reactor fuel cycle. Experiments included criticality, control, power distribution, reaction rate ratios, reactivity coefficients, shielding, kinetics, and spectrum. Analysis was done with three-dimensional nodal diffusion calculations and ENDF/B-V.2 cross sections. Predictions of the ZPPR-15 reactor physics parameters agreed sufficiently well with the measured values to justify confidence in design analyses for metallic-fueled LMRs

  20. The data collection system for failure/maintenance at the Tritium Systems Test Assembly

    International Nuclear Information System (INIS)

    Casey, M.A.; Gruetzmacher, K.M.; Bartlit, J.R.; Cadwallader, L.C.

    1988-01-01

    A data collection system for obtaining information which can be used to help determine the reliability and vailability of future fusion power plants has been installed at the Los Alamos National Laboratory's Tritium Systems Test Assembly (TSTA). Failure and maintenance data on components of TSTA's tritium systems have been collected since 1984. The focus of the data collection has been TSTA's Tritium Waste Tratment System (TWT), which has maintained high availability since it became operation in 1982. Data collection is still in progress and a total of 291 failure reports are in the data collection system at this time, 47 of which are from the TWT. 6 refs., 2 figs., 2 tabs

  1. Experiments on a ceramic electrolysis cell and a palladium diffuser at the tritium systems test assembly

    International Nuclear Information System (INIS)

    Konishi, Satoshi; Yoshida, Hiroshi; Ohno, Hideo; Naruse, Yuji; Coffin, D.O.; Walthers, C.R.; Binning, K.E.

    1985-01-01

    A ceramic electrolysis cell and a palladium diffuser are developed in Japan and is tested with tritium in Tritium Systems Test Assembly (TSTA) of the Los Alamos National Laboratory, in order to confirm the feasibility as possible upgrades for the fuel cleanup system (PCU). The ceramic electrolysis cell made of stabilized zirconia was operated at 630 0 C for an extended period with a mixture of 3% T 2 O in He carrier gas in the circulation system with oxidizing catalyst bed. The palladium diffuser was tested with circulated pure tritium gas at 280 0 C to verify the compatibility of the alloy with tritium, since the 3 He produced in the metal could cause a degradation. The isotopic effects were also measured for both devices

  2. Fusion fuel purification during the Tritium Systems Test Assembly 3-week loop experiment

    International Nuclear Information System (INIS)

    Willms, R.S.

    1989-01-01

    During the time period from April 19, 1989--May 5, 1989, the Tritium Systems Test Assembly (TSTA) at Los Alamos National Laboratory (LANL) conducted its longest continuous integrated loop operation to date. This provided an opportunity to test some hitherto unproven capabilities of the TSTA Fuel Cleanup System (FCU). Previous FCU tests were reported. The purpose of the FCU is to remove impurities from a stream of hydrogen isotopes (Q 2 ) representative of torus exhaust gas. During this run impurities loadings ranging from 60 to 179 sccm of 90% N 2 and 10% CH 4 were fed to the FCU. Each of the two FCU main flow molecular sieve beds (MSB's) were filled to breakthrough three times. The MSB's were regenerated during loop operations. 2 refs., 6 figs., 2 tabs

  3. Pressure loss tests for DR-BEP of fullsize 17 x 17 PWR fuel assembly

    International Nuclear Information System (INIS)

    Chung, Moon Ki; Chun, Se Young; Chang, Seok Kyu; Won, Soon Youn; Cho, Young Rho; Kim, Bok Deuk; Min, Kyoung Ho

    1993-01-01

    This report describes the conditions, procedure and results in the pressure loss tests carried out for a double grid type debris resistance bottom end piece (DR-BEP) designed by KAERI. In this test, the pressure loss coefficients of the full size 17 x 17 PWR simulated fuel assembly with DR-BET and with standard-BEP were measured respectively, and the pressure loss coefficients of DR-BEP were compared with the coefficients of STD-BET. The test conditions fall within the ranges of loop pressure from 5.2 to 45 bar, loop temperature from 27 to 221 deg C and Reynolds number in fuel bundle from 2.17 x 10 4 to 3.85 x 10 5 . (Author) 5 refs., 18 figs., 5 tabs

  4. Remote replacement of materials open-test assembly specimens at the FFTF/IEM cell

    International Nuclear Information System (INIS)

    Gibbons, P.W.; Ramsey, E.B.

    1990-01-01

    The Fast Flux Test Facility (FFTF) interim examination and maintenance (IEM) cell is used for the remote disassembly of irradiated fuel and materials experiments. The materials open-test assembly (MOTA) is brought to the IEM cell for materials test specimen removal. The specimens are shipped to the materials laboratory for sorting and installation in new specimen holders and then returned within 10 days to the IEM cell where they are installed in a new MOTA vehicle for further irradiation. Reconstituting a MOTA is a challenging remote operation involving dozens of steps and two separate facilities. Handling and disassembling sodium-wetted components pose interesting handling, cleaning, and disposal challenges. The success of this system is evidenced by its timely completion in the critical path of FFTF outage schedules

  5. Quality Assurance and Functionality Tests on Electrical Components during the ATLAS IBL Production

    CERN Document Server

    Jentzsch, J; The ATLAS collaboration

    2012-01-01

    For the first ATLAS pixel upgrade scheduled in 2013 a new front-end chip generation (FE- I4) has been developed. The second version (FE-I4B) hosting two different solid-state sensor technologies (planar silicon and 3D silicon) has been produced to be built into a new pixel layer (the Insertable B-Layer, IBL). Prototypes of these assembled modules have been tested in laboratory and testbeam measurements before and after irradiation. Quality assurance measurements under clean room conditions, including temperature and humidity control, have been and will be performed on the required parts during the various production steps of the IBL, namely connectivity as well as electrical tests and signal probing on individual parts and also assembled subsystems. Test results of measurements on flexes, modules and staves will be presented.

  6. 21 CFR 640.56 - Quality control test for potency.

    Science.gov (United States)

    2010-04-01

    ... quality control test for potency may be performed by a clinical laboratory which meets the standards of... 21 Food and Drugs 7 2010-04-01 2010-04-01 false Quality control test for potency. 640.56 Section...) BIOLOGICS ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Cryoprecipitate § 640.56 Quality control...

  7. Irradiation Test in HANARO of the Parts of an X-Gen Nuclear Fuel Assembly

    Energy Technology Data Exchange (ETDEWEB)

    Choo, K. N.; Kim, B. G.; Kang, Y. H. (and others)

    2008-08-15

    An instrumented capsule of 07M-13N was designed, fabricated and irradiated for an evaluation of the neutron irradiation properties of the parts of an X-Gen nuclear fuel assembly for PWR requested by KNF. Some specimens requested by Westinghouse Co. and Hanyang university were also inserted. 389 KNF specimens such as bucking and spring test specimens of 1x1 cell spacer grid, tensile, microstructure and tensile of welded parts, irradiation growth, spring test specimens made of HANA tube, Zirlo, Zircaloy-4, Inconel-718 were placed in the capsule. The capsule was composed of 5 stages having many kinds of specimens and an independent electric heater at each stage. During the irradiation test, the temperature of the specimens and the thermal/fast neutron fluences were measured by 14 thermocouples and 7 sets of Ni-Ti-Fe (2 sets contain additional Nb-Ag) neutron fluence monitors installed in the capsule. The capsule was irradiated for 59.19days (4 cycles) in the CT test hole of HANARO of a 30MW thermal output at 300 {approx} 420 .deg. C(for KNF specimens) up to a fast neutron fluence of 1.27x10{sup 21}(n/cm{sup 2}) (E>1MeV). After an irradiation test, the main body of the capsule was cut off at the bottom of the protection tube with a cutting system and it was transported to the IMEF (Irradiated Materials Examination Facility). The irradiated specimens were tested to evaluate the irradiation performance of the parts of an X-Gen fuel assembly in the IMEF hot cell.

  8. Mechanical characterization tests of a candidate skeleton for X-Gen fuel assembly

    International Nuclear Information System (INIS)

    Kim, Hyung Kyu; Yoon, Kyung Ho; Lee, Kang Hee; Kim, Jae Yong; Lee, Young Ho

    2007-09-01

    Since the KNFC (KEPCO Nuclear Fuel Co.) requested a mechanical characterization tests of a candidate skeleton for X-Gen fuel assembly (some welding locations of a center guide tube are free of welding compared with the PLUS7 case) were requested, transverse vibration and stiffness tests were carried out by using the FAMeCT. The major results are as follows. - Transverse vibration test There was no distinguishable discrepancy in the free vibration characteristics between the skeleton without welding at some locations of a center guide tube and that of original assembly (PLUS7; welded at every spacer grid locations). The natural frequencies were measured as 6.8 - 6.9 for the 1st mode; 17.7 - 18.3 for the 2nd mode; 30.2 - 31.2 for the 3rd mode; 50.4 - 52.1 Hz for the 4th mode. As a result, the difference in the vibration characteristics was extremely small regardless of the number of welding of a center guide tube. - Transverse bending test. The transverse bending test results of the X-Gen no. 2 were similar to those of the PLUS7 skeleton. The relationship between the force and displacement was found linear. 521 N was observed at the deflection of 30 mm, and the stiffness at the 6th grid location (load exerting location) was 17.4, 16.3 N/mm in the two consecutive tests. The displacements at the grid locations lower than the 6th grid were at bit smaller than those upper than that due to a comparatively higher rigidity

  9. Some observations about quality control tests of Spect

    International Nuclear Information System (INIS)

    Robilotta, C.C.; Rebelo, M.F.S.; Oliveira, M.A.

    1987-01-01

    Some observations about quality control tests done in the tomographic system of Heart Institute are described. Among the tests, the traditional test of quality control with scintillation camera and the specific test for tomography systems are induced. The traditional tests are essential, but not sufficient for evaluating the Spect equipment and the specific tests have been effectuated in controlled conditions. (C.G.C.) [pt

  10. High burnup performance of an advanced oxide fuel assembly in FFTF [Fast Flux Test Facility] with ferritic/martensitic materials

    International Nuclear Information System (INIS)

    Bridges, A.E.; Saito, G.H.; Lovell, A.J.; Makenas, B.J.

    1986-05-01

    An advanced oxide fuel assembly with ferritic/martensitic materials has successfully completed its sixth cycle of irradiation in the FFTF, reaching a peak pellet burnup greater than 100 MWd/KgM and a peak fast fluence greater than 15 x 10 22 n/cm 2 . The cladding, wire-wrap, and duct material for the ACO-1 test assembly is the ferritic/martensitic alloy, HT9, which was chosen for use in long-lifetime fuel assemblies because of its good nominal temperature creep strength and low swelling rate. Valuable experience on the performance of HT9 materials has been gained from this test, advancing our quest for long-lifetime fuel. Pertinent data, obtained from the ACO-1 test assembly, will support the irradiation of the Core Demonstration Experiment in FFTF

  11. Critical heat flux tests for a 12 finned-element assembly

    Energy Technology Data Exchange (ETDEWEB)

    Yang, J., E-mail: Jun.Yang@cnl.ca; Groeneveld, D.C.; Yuan, L.Q.

    2017-03-15

    Highlights: • CHF tests for a 12 finned-fuel-element assembly at highly subcooled conditions. • Test approach to maximize experimental information and minimize heater failures. • Three series of tests were completed in vertical upward light water flow. • Bundle simulators of two axial power profiles and three heated lengths were tested. • Results confirm that the prediction method predicts lower CHF values than measured. - Abstract: An experimental study was undertaken to provide relevant data to validate the current critical heat flux (CHF) prediction method of the NRU driver fuel for safety analysis, i.e., to confirm no CHF occurrence below the predicted values. The NRU driver fuel assembly consists of twelve finned fuel elements arranged in two rings – three in the inner ring and nine in the outer ring. To satisfy the experimental objective tests at very high heat fluxes, very high mass velocities, and high subcoolings were conducted where the CHF mechanism is the departure from nucleate boiling (DNB). Such a CHF experiment can be very difficult, costly and time consuming since failure of the heating surface due to rupture or melting (physical burnout) is expected when the DNB type of CHF is reached. A novel experimental approach has been developed to maximize the amount of relevant experimental information on safe operating conditions in the tests, and to minimize any possible heater failures that inherently accompany the CHF occurrence at these conditions. Three series of tests using electrically heated NRU driver fuel simulators with three heated lengths and two axial power profiles (or axial heat flux distribution (AFD)) were completed in vertical upward light water flow. Each series of tests covered two mass flow rates, several heat flux levels, and local subcoolings that bound the ranges of interest for the analysis of postulated slow loss-of-regulation accident (LORA) and loss-of-flow accident (LOFA) scenarios. Tests for each mass flow rate of

  12. Drop performance test of conceptually designed control rod assembly for prototype generation IV sodium-cooled fast reactor

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Young Kyu; Lee, Jae Han; Kim, Hoe Woong; KIm, Sung Kyun; Kim, Jong Bum [Sodium-cooled Fast Reactor NSSS Design Division, Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2017-06-15

    The control rod assembly controls reactor power by adjusting its position during normal operation and shuts down chain reactions by its free drop under scram conditions. Therefore, the drop performance of the control rod assembly is important for the safety of a nuclear reactor. In this study, the drop performance of the conceptually designed control rod assembly for the prototype generation IV sodium-cooled fast reactor that is being developed at the Korea Atomic Energy Research Institute as a next-generation nuclear reactor was experimentally investigated. For the performance test, the test facility and test procedure were established first, and several free drop performance tests of the control rod assembly under different flow rate conditions were then carried out. Moreover, performance tests under several types and magnitudes of seismic loading conditions were also conducted to investigate the effects of seismic loading on the drop performance of the control rod assembly. The drop time of the conceptually designed control rod assembly for 0% of the tentatively designed flow rate was measured to be 1.527 seconds, and this agrees well with the analytically calculated drop time. It was also observed that the effect of seismic loading on the drop time was not significant.

  13. A comparative evaluation of genome assembly reconciliation tools.

    Science.gov (United States)

    Alhakami, Hind; Mirebrahim, Hamid; Lonardi, Stefano

    2017-05-18

    The majority of eukaryotic genomes are unfinished due to the algorithmic challenges of assembling them. A variety of assembly and scaffolding tools are available, but it is not always obvious which tool or parameters to use for a specific genome size and complexity. It is, therefore, common practice to produce multiple assemblies using different assemblers and parameters, then select the best one for public release. A more compelling approach would allow one to merge multiple assemblies with the intent of producing a higher quality consensus assembly, which is the objective of assembly reconciliation. Several assembly reconciliation tools have been proposed in the literature, but their strengths and weaknesses have never been compared on a common dataset. We fill this need with this work, in which we report on an extensive comparative evaluation of several tools. Specifically, we evaluate contiguity, correctness, coverage, and the duplication ratio of the merged assembly compared to the individual assemblies provided as input. None of the tools we tested consistently improved the quality of the input GAGE and synthetic assemblies. Our experiments show an increase in contiguity in the consensus assembly when the original assemblies already have high quality. In terms of correctness, the quality of the results depends on the specific tool, as well as on the quality and the ranking of the input assemblies. In general, the number of misassemblies ranges from being comparable to the best of the input assembly to being comparable to the worst of the input assembly.

  14. Tritium handling experience in vacuum systems at TSTA [Tritium Systems Test Assembly

    International Nuclear Information System (INIS)

    Anderson, J.L.; Jenkins, E.M.; Walthers, C.R.; Yoshida, H.; Fukui, H.; Naruse, Y.

    1989-01-01

    Compound cryopumps have been added to the Tritium Systems Test Assembly (TSTA) integrated fusion fuel loop. Operations have been performed which closely simulate an actual fusion reactor pumping scenario. In addition, performance data have been taken that support the concept of using coconut charcoal as a sorbent at 4K for pumping helium. Later tests show that coconut charcoal may be used to co-pump D,T and He mixtures on a single 4K panel. Rotary spiral pumps have been used successfully in several applications at TSTA and have acquired more than 9000 hours of maintenance-free operation. Metal bellows pumps have been used to back the spiral pumps and have been relatively trouble free in loop operations. Bellows pumps also have more than 9000 hours of maintenance-free operation. 5 refs., 6 figs

  15. Should We Stop Developing Heuristics and Only Rely on Mixed Integer Programming Solvers in Automated Test Assembly? A Rejoinder to van der Linden and Li (2016).

    Science.gov (United States)

    Chen, Pei-Hua

    2017-05-01

    This rejoinder responds to the commentary by van der Linden and Li entiled "Comment on Three-Element Item Selection Procedures for Multiple Forms Assembly: An Item Matching Approach" on the article "Three-Element Item Selection Procedures for Multiple Forms Assembly: An Item Matching Approach" by Chen. Van der Linden and Li made a strong statement calling for the cessation of test assembly heuristics development, and instead encouraged embracing mixed integer programming (MIP). This article points out the nondeterministic polynomial (NP)-hard nature of MIP problems and how solutions found using heuristics could be useful in an MIP context. Although van der Linden and Li provided several practical examples of test assembly supporting their view, the examples ignore the cases in which a slight change of constraints or item pool data might mean it would not be possible to obtain solutions as quickly as before. The article illustrates the use of heuristic solutions to improve both the performance of MIP solvers and the quality of solutions. Additional responses to the commentary by van der Linden and Li are included.

  16. Improvement of the test quality for specific test problems. Proceedings

    International Nuclear Information System (INIS)

    2011-01-01

    This proceedings CD discusses the many factors that are relevant in nearly all tests, as well as their effects on the validity of the test result. Interfaces with technical rules, staff qualification, POD, and validation of test results by supplementary techniques are presented as well. Three of the 17 papers are available as separate records in the ENERGY database. [de

  17. EUROFAB: fabrication of four MOX lead tests assemblies for the US DOE

    International Nuclear Information System (INIS)

    Jean-Pierre Bariteau

    2006-01-01

    In a multilateral agreement, the United States (US) and the Russian Federation agreed to reduce their respective weapons stockpiles by each country disposing of 34 tons of military origin plutonium. On behalf of the US government, the Department of Energy contracted with Duke, COGEMA, Stone and Webster (DCS) to design a Mixed Oxide Fuel Fabrication facility (MFFF) which would be built and operated at the DOE Savannah River Site near Aiken, South Carolina. This plant will transform the US excess weapons stockpile into MOX fuel, which will be used it in existing domestic commercial power reactors. The MFFF is based on a replication of AREVA existing facilities (La Hague for Pu polishing and Melox for MOX fabrication). In parallel with the design, construction and startup of the MFFF facility, DOE commissioned fabrication and irradiation of 4 lead test assemblies in one of the Mission Reactors to assist in obtaining NRC approval for MOX fuel loading in US NPPs prior to the production phase of the MFFF facility. This program was named 'EUROFAB', since fabrication had to be made in Europe because no facility implementing the MFFF technology was existing in the USA. The COGEMA Recycling Business unit transmitted a bid to DCS in April 2003, which proposed to perform Eurofab fabrication in its Cadarache (pellets and rods) and Melox (assembly mounting) facilities. In August 2003, the decision was made by DCS, on behalf of the DOE, to award the EUROFAB fabrication contract to COGEMA. (author)

  18. Recent palladium membrane reactor development at the tritium systems test assembly

    International Nuclear Information System (INIS)

    Willms, R.S.; Birdsell, S.A.; Wilhelm, R.C.

    1995-01-01

    The palladium membrane reactor (PMR) is proving to be a simple and effective means for recovering hydrogen isotopes from fusion fuel impurities such as methane and water. This device directly combines two techniques which have long been utilized for hydrogen processing, namely catalytic shift reactions and palladium/silver permeators. A proof-of-principle (PMR) has been constructed and tested at the Tritium Systems Test Assembly of Los Alamos National Laboratory. The first tests with this device showed that is was effective for the proposed purpose. Initial work concluded that a nickel catalyst was an appropriate choice for use in a PMR. More detailed testing of the PMR with such a catalyst was performed and reported in other works. It was shown that a nickel catalyst-packed PMR did, indeed, recover hydrogen from water and methane with efficiencies approaching 100% in a single processing pass. These experiments were conducted over an extended period of time and no failure or need for regeneration was encountered. These positive results have prompted further PMR development. Topics addressed include alternate PMR geometries and initial testing of the PMR with tritium. These are the subjects of this paper

  19. Lageos assembly operation plan

    Science.gov (United States)

    Brueger, J.

    1975-01-01

    Guidelines and constraints procedures for LAGEOS assembly, operation, and design performance are given. Special attention was given to thermal, optical, and dynamic analysis and testing. The operation procedures illustrate the interrelation and sequence of tasks in a flow diagram. The diagram also includes quality assurance functions for verification of operation tasks.

  20. The approximate thermal-model-testing method for non-stationary temperature fields in central zones of fast reactor assemblies

    International Nuclear Information System (INIS)

    Mikhin, V.I.; Matukhin, N.M.

    2000-01-01

    The approach to generalization of the non-stationary heat exchange data for the central zones of the nuclear reactor fuel assemblies and the approximate thermal-model-testing criteria are proposed. The fuel assemblies of fast and water-cooled reactors with different fuel compositions have been investigated. The reason of the non-stationary heat exchange is the fuel-energy-release time dependence. (author)

  1. Fabrication and quality assurance of some important components and sub-assemblies for Prototype Fast Breeder Reactor (PFBR) project

    International Nuclear Information System (INIS)

    Dutta, N.G.; More, S.S.

    2010-01-01

    Bharatiya Nabhikiya Vidyut Nigam (BHAVINI) is engaged in construction of 500 MWe prototype fast breeder reactor (PFBR) at Kalpakkam, Chennai. In this very important and prestigious national programmed M/s Kay Bouvet Engg. Pvt. Ltd. (M/s KBEPL) Satara is contributing in a major way by supplying many important sub-assemblies. M/s KBEPL is engaged in manufacturing, quality assurance and supply of many subassemblies of PFBR like under water trolley (UWT), shielding door, container and container storage rack (CSR), vessel in fuel transfer cell (FTC), personnel air lock (PAL), emergency air lock (EAL) and material air lock (MAL), absorber rod drive mechanism (ARDM) flask assembly and carriage in MAL etc. Two partition doors and four nos. of embedded parts (SS 304L) have already been supplied to Bhavini. The paper deals with manufacturing and Q.A. activities being carried out for supply of these important assemblies to PFBR projects. (author)

  2. Quality of routine spirometry tests in Dutch general practices

    Science.gov (United States)

    Schermer, Tjard RJ; Crockett, Alan J; Poels, Patrick JP; van Dijke, Jacob J; Akkermans, Reinier P; Vlek, Hans F; Pieters, Willem R

    2009-01-01

    Background Spirometry is an indispensable tool for diagnosis and monitoring of chronic airways disease in primary care. Aim To establish the quality of routine spirometry tests in general practice, and explore associations between test quality and patient characteristics. Design of study Analysis of routine spirometry test records. Setting Fifteen general practices which had a working agreement with a local hospital pulmonary function laboratory for spirometry assessment regarding test quality and interpretation. Method Spirometry tests were judged by a pulmonary function technician and a chest physician. Proportions of test adequacy were analysed using markers for manoeuvre acceptability and test reproducibility derived from the 1994 American Thoracic Society spirometry guideline. Associations between quality markers and age, sex, and severity of obstruction were examined using logistic regression. Results Practices performed a mean of four (standard deviation = 2) spirometry tests per week; 1271 tests from 1091 adult patients were analysed; 96.4% (95% confidence interval [CI] = 95.6 to 97.2) of all tests consisted of ≥3 blows. With 60.6% of tests, forced expiratory time was the marker with the lowest acceptability rate. An overall 38.8% (95% CI = 36.0 to 41.6) of the tests met the acceptability as well as reproducibility criteria. Age, sex, and severity of obstruction were associated with test quality markers. Conclusion The quality of routine spirometry tests was better than in previous reports from primary care research settings, but there is still substantial room for improvement. Sufficient duration of forced expiratory time is the quality marker with the highest rate of inadequacy. Primary care professionals should be aware of patient characteristics that may diminish the quality of their spirometry tests. Further research is needed to establish to what extent spirometry tests that are inadequate, according to stringent international expert criteria

  3. DOE standard: Quality assurance inspection and testing of HEPA filters

    International Nuclear Information System (INIS)

    1999-02-01

    This standard establishes essential elements for the quality assurance inspection and testing of HEPA filters by US Department of Energy (DOE)-accepted Filter Test Facilities (FTF). The standard specifies HEPA filter quality assurance inspection and testing practices established in DOE-STD-3022-98, DOE HEPA Filter Test Program, and provides a basis for the preparation of written operating procedures for primary FTF functions

  4. Construction and testing of a blower-door assembly for regulation of air pressure within structures

    International Nuclear Information System (INIS)

    Steele, W.D.

    1987-09-01

    The Technical Measurements Center is evaluating several methods to decrease the time required to determine an annual average radon-daughter concentration in structures. One method involves stabilizing the air pressure within the structure at a constant pressure with reference to external atmospheric or soil-gas pressure. This report describes the construction and preliminary testing of a blower-door system to maintain a constant differential air pressure within a structure. The blower-door assembly includes a collapsible frame and a large fan to occlude a doorway, a damper with an actuator to control air flow, a controller to drive the damper actuator, and a pressure transducer to measure the differential pressure. Preliminary testing of the system indicates that pressure within the structure in the range of 1 to 20 Pascals can be held to within approximately +-1 Pa of the set point. Further testing of the blower-door system is planned to provide data on the applicability of this method to short-duration tests for annual average radon-daughter concentration estimates. 13 figs., 1 tab

  5. Preliminary analysis of the safety and environmental impact of the Tritium Systems Test Assembly

    International Nuclear Information System (INIS)

    Carlson, R.V.; Jalbert, R.A.

    1980-01-01

    The Tritium Systems Test Assembly (TSTA) is a facility dedicated to the development of technologies associated with the D-T fuel cycle of future fusion reactors while demonstrating that TSTA can be operated safely with no significant losses to the environment. During the initial design stage of TSTA, a safety analysis was performed which investigated the effects of major subsystem component failure, the meteorology and seismicity of the site and their possible effect on the facility, and accident scenarios which result in tritium releases. Major releases of tritium to the environment are considered highly improbable since they require a compound failure of primary and secondary containment, along with either a breach of the building or a failure of the Emergency Tritium Cleanup system. Accidental releases caused by natural phenomena (earthquake, tornado, etc.) are considered highly improbable

  6. Description of a reference design tokamak for the Technology Test Assembly

    International Nuclear Information System (INIS)

    Haubenreich, P.N.

    1975-10-01

    Early conceptual studies for the Technology Test Assembly involved a reference conceptual design for a tokamak with superconducting toroidal field magnets. The TF magnet conductors are NbTi filaments in a copper matrix. The 24 TF coils and associated structure operate at 4--5 K and a maximum field (at the windings) of 75 kG. Principal dimensions of the machine are: TF coil bore, 1.8 x 2.4 m (oval); major radius, 2.25 m; plasma minor radius, 0.6 m. A preliminary but detailed cost estimate for the reference machine was prepared to serve as an anchor point for cost scaling for larger machines in subsequent TTA parameter studies

  7. Test beam analysis of ultra-thin hybrid pixel detector assemblies with Timepix readout ASICs

    CERN Document Server

    Alipour Tehrani, Niloufar; Dannheim, Dominik; Firu, Elena; Kulis, Szymon; Redford, Sophie; Sicking, Eva

    2016-01-01

    The requirements for the vertex detector at the proposed Compact Linear Collider imply a very small material budget: less than 0.2% of a radiation length per detection layer including services and mechanical supports. We present here a study using Timepix readout ASICs hybridised to pixel sensors of 50 − 500 μm thickness, including assemblies with 100 μm thick sensors bonded to thinned 100μm thick ASICs. Sensors from three producers (Advacam, Micron Semiconductor Ltd, Canberra) with different edge termination technologies (active edge, slim edge) were bonded to Timepix ASICs. These devices were characterised with the EUDET telescope at the DESY II test beam using 5.6 GeV electrons. Their performance for the detection and tracking of minimum ionising particles was evaluated in terms of charge sharing, detection efficiency, single-point resolution and energy deposition.

  8. Procedures for parametric studies of costs of superconducting toroidal test assemblies

    International Nuclear Information System (INIS)

    Thompson, P.B.

    1976-05-01

    A cost scaling procedure, based on a detailed reference conceptual design, has been developed to determine the effects of variations in the characteristic parameters of superconducting toroidal field coils on project costs. The primary purpose was to provide reasonably simple rational formulae for obtaining approximate costs of a complete installation, focusing on the trends and sensitivities of costs to changes in various parameters such as field strength, coil size, number of coils, and current density rather than establishing absolute costs. No results are included here because early studies applying these procedures are no longer pertinent to the present Superconducting Magnet Development Program. However, planning for the Large Coil Project and the preliminary conceptual design of the Technology Test Assembly with Plasma have employed the techniques described and results will be reported in the appropriate project documents

  9. 7 CFR 58.442 - Laboratory and quality control tests.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Laboratory and quality control tests. 58.442 Section... Service 1 Operations and Operating Procedures § 58.442 Laboratory and quality control tests. (a) Chemical... Methods or by other methods giving equivalent results. (b) Weight or volume control. Representative...

  10. Quality of routine spirometry tests in Dutch general practices.

    NARCIS (Netherlands)

    Schermer, T.R.J.; Crockett, A.J.; Poels, P.J.P.; Dijke, J.J. van; Akkermans, R.P.; Vlek, H.F.; Pieters, W.R.

    2009-01-01

    BACKGROUND: Spirometry is an indispensable tool for diagnosis and monitoring of chronic airways disease in primary care. AIM: To establish the quality of routine spirometry tests in general practice, and explore associations between test quality and patient characteristics. DESIGN OF STUDY: Analysis

  11. Internal quality control in serological tests for syphilis.

    OpenAIRE

    Wasley, G D

    1985-01-01

    The importance of syphilis serological tests demands that laboratory reports are reliable. Internal quality control applied to the organisation of a syphilis serology service improves laboratory bench performance and reporting. Described here are internal quality control procedures of a department that serves a genitourinary medicine clinic and conducts 70 000 tests a year to investigate for syphilis.

  12. Accelerating the design and testing of LEU fuel assemblies for conversion of Russian-designed research reactors outside Russia

    International Nuclear Information System (INIS)

    Matos, J.E

    2003-01-01

    This paper identifies proposed geometries and loading specifications of LEU tube-type and pin-type test assemblies that would be suitable for accelerating the conversion of Russian-designed research reactors outside of Russia if these fuels are manufactured, qualified by irradiation testing, and made commercially available in Russia. (author)

  13. Quality assurance of radiopharmaceuticals-specifications and test procedures

    International Nuclear Information System (INIS)

    Baldas, J.; Bonnyman, J.; Pojer, P.M.

    1981-08-01

    This report is a compilation of test methods used and specifications adopted for the Radiopharmaceutical Quality Assurance Test Programme conducted by the Australian Radiation Laboratory. In some cases test procedures described have been taken from various Pharmacopoeias or methods published in the literature. In other cases test methods have been developed at the ARL

  14. Component design challenges for the ground-based SP-100 nuclear assembly test

    International Nuclear Information System (INIS)

    Markley, R.A.; Disney, R.K.; Brown, G.B.

    1989-01-01

    The SP-100 ground engineering system (GES) program involves a ground test of the nuclear subsystems to demonstrate their design. The GES nuclear assembly test (NAT) will be performed in a simulated space environment within a vessel maintained at ultrahigh vacuum. The NAT employs a radiation shielding system that is comprised of both prototypical and nonprototypical shield subsystems to attenuate the reactor radiation leakage and also nonprototypical heat transport subsystems to remove the heat generated by the reactor. The reactor is cooled by liquid lithium, which will operate at temperatures prototypical of the flight system. In designing the components for these systems, a number of design challenges were encountered in meeting the operational requirements of the simulated space environment (and where necessary, prototypical requirements) while also accommodating the restrictions of a ground-based test facility with its limited available space. This paper presents a discussion of the design challenges associated with the radiation shield subsystem components and key components of the heat transport systems

  15. Installation, test and non-linear vibratory analysis of an experiment with four fuel assembly models under axial flow

    International Nuclear Information System (INIS)

    Clement, Simon

    2014-01-01

    The present study is in the scope of pressurized water reactors (PWR) core response to earthquakes. The goal of this thesis is to measure the coupling between fuel assemblies caused an axial water flow. The design, production and installation a new test facility named ICARE EXPERIMENTAL are presented. ICARE EXPERIMENTAL was built in order to measure simultaneously the vibrations of four fuel assemblies (2 x 2) under an axial flow. Vibrations are produced by imposing the dynamic of one of the fuel assemblies and the displacements of the three others, induced by the fluid, are measured in the horizontal plane at grids level. A new data analysis method combining time-frequency analysis and orthogonal mode decomposition (POD) is described. This method, named Sliding Window POD (SWPOD), allows analysing multicomponent data, of which spatial repartition of energy and frequency content are time dependent. In the case of mechanical systems (linear and nonlinear), the link between the proper orthogonal modes obtained through SWPOD and the normal modes (linear and nonlinear) is studied. The SWPOD is applied to experimental tests of a steam generators U-tube, showing the appearance of internal resonances. The method is also applied to dynamic experimental tests of a fuel assembly under axial flow, the evolution of its normal modes is obtained as a function of the fluid velocity. The measures acquired with the ICARE EXPERIMENTAL installation are analysed using the SWPOD. The first results show characteristic behavior of the free fuel assemblies at their resonances. The coupling between fuel assemblies, induced by the fluid, is reproduced by simulations performed using the COEUR3D code. This code is based on a porous media model in order to simulate a fuel assemblies network under axial flow. (author) [fr

  16. Overview of tritium processing development at the tritium systems test assembly

    International Nuclear Information System (INIS)

    Anderson, J.L.

    1986-01-01

    The Tritium Systems Test Assembly (TSTA) at the Los Alamos National Laboratory has been operating with tritium since June 1984. Presently there are some 50 g of tritium in the main processing loop. This 50 g has been sufficient to do a number of experiments involving the cryogenic distillation isotope separation system and to integrate the fuel cleanup system into the main fuel processing loop. In January 1986 two major experiments were conducted. During these experiments the fuel cleanup system was integrated, through the transfer pumping system, with the isotope separation system, thus permitting testing on the integrated fuel processing loop. This integration of these systems leaves only the main vacuum system to be integrated into the TSTA fuel processing loop. In September 1986 another major tritium experiment was performed in which the integrated loop was operated, the tritium inventory increased to 50 g and additional measurements on the performance of the distillation system were taken. In the period June 1984 through September 1986 the TSTA system has processed well over 10 8 Ci of tritium. Total tritium emissions to the environment over this period have been less than 15 Ci. Personnel exposures during this period have totaled less than 100 person-mRem. To date, the development of tritium technology at TSTA has proceeded in progressive and orderly steps. In two years of operation with tritium, no major design flows have been uncovered

  17. Test of Flow Characteristics in Tubular Fuel Assembly I - Establishment of test loop and measurement validation test

    International Nuclear Information System (INIS)

    Park, Jong Hark; Chae, H. T.; Park, C.; Kim, H.

    2005-12-01

    Tubular type fuel has been developed as one of candidates for Advanced HANARO Reactor(AHR). It is necessary to test the flow characteristics such as velocity in each flow channels and pressure drop of tubular type fuel. A hydraulic test-loop to examine the hydraulic characteristics for a tubular type fuel has been designed and constructed. It consists of three parts; a) piping-loop including pump and motor, magnetic flow meter and valves etc, b) test-section part where a simulated tubular type fuel is located, and 3) data acquisition system to get reading signals from sensors or instruments. In this report, considerations during the design and installation of the facility and the selection of data acquisition sensors and instruments are described in detail. Before doing the experiment to measure the flow velocities in flow channels, a preliminary tests have been done for measuring the coolant velocities using pitot-tube and for validating the measurement accuracy as well. Local velocities of the radial direction in circular tubes are measured at regular intervals of 60 degrees by three pitot-tubes. Flow rate inside the circular flow channel can be obtained by integrating the velocity distribution in radial direction. The measured flow rate was compared to that of magnetic flow meter. According to the results, two values had a good agreement, which means that the measurement of coolant velocity by using pitot-tube and the flow rate measured by the magnetic flow meter are reliable. Uncertainty analysis showed that the error of velocity measurement by pitot-tube is less than ±2.21%. The hydraulic test-loop also can be adapted to others such as HANARO 18 and 36 fuel, in-pile system of FTL(Fuel Test Loop), etc

  18. Quality Assurance Tests of the CMS Endcap RPCs

    CERN Document Server

    Ahmed, Ijaz; Hamid Ansari, M; Irfan Asghar, M; Asghar, Sajjad; Awan, Irfan Ullah; Butt, Jamila; Hoorani, Hafeez R; Hussain, Ishtiaq; Khurshid, Taimoor; Muhammad, Saleh; Shahzad, Hassan; Aftab, Zia; Iftikhar, Mian; Khan, Mohammad Khalid; Saleh, M

    2008-01-01

    In this note, we have described the quality assurance tests performed for endcap Resistive Plate Chambers (RPCs) at two different sites, Pakistan Atomic Energy Commission (PAEC) and National Centre for Physics (NCP), in Pakistan. This paper describes various quality assurance tests both at the level of gas gaps and the chambers. The data has been obtained at different time windows during the large scale production of CMS RPCs of RE2/2 and RE2/3 type. In the quality assurance tests, we have investigated parameters like dark current, strip occupancy, cluster size and efficiency of RPCs.

  19. Overview of Power Quality and Integrated Testing at JSC

    Science.gov (United States)

    Davies, Francis

    2018-01-01

    This presentation describes the basic philosophy behind integrated testing and partially integrated testing. It lists some well known errors in space systems that were or could have been caught during integrated testing. Two examples of integrated testing at the Johnson Space Center (JSC) are mentioned, and then an overview of two test facilities that do power testing (partially integrated testing) at JSC are presented, with information on the capabilities of each. Finally a list of three projects that has problems caught during power quality or Electromagnetic Interference (EMI) testing is presented.

  20. Test Code Quality and Its Relation to Issue Handling Performance

    NARCIS (Netherlands)

    Athanasiou, D.; Nugroho, A.; Visser, J.; Zaidman, A.

    2014-01-01

    Automated testing is a basic principle of agile development. Its benefits include early defect detection, defect cause localization and removal of fear to apply changes to the code. Therefore, maintaining high quality test code is essential. This study introduces a model that assesses test code

  1. A Neural Assembly-Based View on Word Production: The Bilingual Test Case

    Science.gov (United States)

    Strijkers, Kristof

    2016-01-01

    I will propose a tentative framework of how words in two languages could be organized in the cerebral cortex based on neural assembly theory, according to which neurons that fire synchronously are bound into large-scale distributed functional units (assemblies), which represent a mental event as a whole ("gestalt"). For language this…

  2. Nupec thermal hydraulic test to evaluate post-DNB characteristics for PWR fuel assemblies (1. general test plan and results)

    International Nuclear Information System (INIS)

    Norio, Kono; Kenji, Murai; Kaichiro, Misima; Takayuki, Suemura; Yoshiei, Akiyama; Keiichi, Hori

    2001-01-01

    In the present thermal hydraulic design of Pressurized Water Reactor (PWR), a departure from nucleate boiling (DNB) under anticipated transient conditions is not allowed. However, it is recognized that the DNB dose not cause a fuel rod failure immediately, and a suitable reactor trip can prevent the core from severe damages. If the fuel rod temperature under the post-DNB conditions can be accurately evaluated, the potentially existing margin in the present design method will be quantitatively assessed. To establish the heat transfer evaluation method on post-DNB event for PWR thermal hydraulic design, Nuclear Power Engineering Corporation (NUPEC) started a program, NUPEC Thermal Hydraulic Test to Evaluate Post-DNB Characteristics for PWR Fuel Assemblies (NUPEC-TH-P), in 1995 (hereinafter the year means fiscal year) under the sponsorship of Ministry of Economy, Trade and industry (METI). This program is now under going until 2001. This paper is to show the overall plan and the status of NUPEC-TH-P. (authors)

  3. Quality of HIV laboratory testing in Tanzania: a situation analysis ...

    African Journals Online (AJOL)

    December 2004 to February 2005 in 12 laboratories which were conveniently selected to represent all the zones of Tanzania. The questionnaires comprised of questions on laboratory particulars, internal and external quality control for HIV testing and quality control of reagents. Source and level of customer satisfaction of ...

  4. Production and quality testing of fuel briquettes made from ...

    Indian Academy of Sciences (India)

    Santhosh Ujjinappa

    2018-04-13

    Apr 13, 2018 ... Thus, this work proved that the blending of PS and TS gives better quality briquettes ... parameters such as compressed density, relaxed density, relaxation ratio ... developed for coal. The test was conducted after two weeks.

  5. Suggestion for improvement of PET quality control tests in Brazil

    International Nuclear Information System (INIS)

    Ferreira, Fernanda C.L.; Magalhaes, Cinthia M.S.; Souza, Divanizia N.

    2009-01-01

    Nowadays nuclear medicine has a considerable importance among the other medical specialties. This medical specialty utilizes high-tech equipment for imaging in the diagnosis, obtaining information on the clinical functionality of organs and systems of the human body through the use of radioisotopes . In view of the importance of guaranteeing the image quality in SPECT and PET systems, enabling patients not repeat exams due to lack of quality control of equipment used in nuclear medicine, this paper aims to present a possible suggestion to update the quality control tests needed for quality assurance of nuclear medicine services. They were considered the requirements of the National Commission of Nuclear Energy (CNEN) and the National Health Surveillance Agency (ANVISA) in Brazil. The minimum requirements to be defined for inclusion of quality control tests on PET in the standard CNEN are extremely important because they will guide the evaluation of PET systems, determining the quality control tests to be performed. And those tests for PET will be a regulatory requirement by the CNEN and ANVISA. As the National Health Surveillance Agency has already publication of RDC 38 with recommendations for services of nuclear medicine. This study will continue with evaluation of PET systems and presenting the tests of quality control with additional objects and simulators to ensure safety in PET systems have not standardized in nuclear medicine services in Brazil. (author)

  6. 6. colloquium on quality assurance by materials testing. Proceedings

    International Nuclear Information System (INIS)

    2001-01-01

    This conference, now in its tenth year, has become an integral element of nondestructive testing research in Germany. It focuses on the role of nondestructive testing as a tool of in-house quality management and presents practical solutions. In accordance with its long tradition in the motor car industry, this is still a central field of interest. This CD-ROM provides information on shorter development times, diversified type production, modern high-productivity fabrication, and higher quality specifications. (orig.) [de

  7. 75 FR 3253 - Lamb Assembly and Test, LLC, Subsidiary of Mag Industrial Automation Systems, Machesney Park, IL...

    Science.gov (United States)

    2010-01-20

    ... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-70,516] Lamb Assembly and Test, LLC, Subsidiary of Mag Industrial Automation Systems, Machesney Park, IL; Notice of Negative... workers of Lamb Technicon, a division of Unova, Warren, Michigan and Lake Orion, Michigan were previously...

  8. Comparison of Integer Programming (IP) Solvers for Automated Test Assembly (ATA). Research Report. ETS RR-15-05

    Science.gov (United States)

    Donoghue, John R.

    2015-01-01

    At the heart of van der Linden's approach to automated test assembly (ATA) is a linear programming/integer programming (LP/IP) problem. A variety of IP solvers are available, ranging in cost from free to hundreds of thousands of dollars. In this paper, I compare several approaches to solving the underlying IP problem. These approaches range from…

  9. Experimental Study of an Assembly with Extreme Particulate, Molecular, and Biological Requirements in Different Environmental Scenarios from Quality Point of View

    Science.gov (United States)

    Müller, A.; Urich, D.; Kreck, G.; Metzmacher, M.; Lindner, R.

    2018-04-01

    The presentation will cover results from an ESA supported investigation to collect lessons learned for mechanism assembly with the focus on quality and contamination requirements verification in exploration projects such as ExoMars.

  10. An impact test system design and its applications to dynamic buckling of a spacer grid assembly

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Sheng, E-mail: liusheng_05@126.com; Fan, Chenguang; Yang, Yiren

    2016-11-15

    This study is aimed at investigating the dynamic buckling load, dynamic stiffness, damping and buckling characteristics of the spacer grid assembly (SGA). A pendulum impact test system is designed to experiment the buckling of SGAs. Three criterions are discussed and compared to determine the buckling loads of SGAs: B-R criterion, energy criterion and extreme value criterion. Two approaches are applied to calculate the dynamic stiffness of SGAs: One method is natural period method based on the hypothesis of harmonic motion of the pendulum whose period is approximated because of the passivation and tailing of the impact force time history; and the other is energy method based on the conservation of mechanical energy. The equivalent viscous damping is defined as the resultant cause of dissipation and is obtained by the energy principle. The impact force time history loses its approximate symmetry after buckling occurs. The impact force and displacement reach their maxima almost at the same time at pre-buckling states but not post-buckling states. Vertical straps in SGA are found to be transversely shared by horizontal straps at the buckling position. The buckling of SGA results from the lack of strength of complete structure; and the strength of material has no effects on the buckling.

  11. A modification design and adjusting test for instruments and control system of critical assembly

    International Nuclear Information System (INIS)

    Wu Manrong; Li Guangjian

    1996-12-01

    A more reliable and safe control system and it's instruments for HFETRCA (high flux engineering test reactor critical assembly) have been built. In the system high performance CMOS unit was used, which has high integration, strong anti-interference and high trigger threshold. In the design of control rod driving circuit, the speed negative feedback principle was applied that results in more stable rotating rate of motors of transmission mechanism and more flexibility of adjusting rod speed. In order to improve reactor safety in accident, additional control circuit is equipped, by which not only control rods with electromagnet will rapidly drop but also other control rods will insert at the speed of 2∼6 times faster than the normal inserting speed. The key technique in the adjustment and new method of anti-interference are also introduced. After more than 40 times physical experiments with (4 x 4 - 4) fuel element in HFETRC, it is proved that the design and adjustment of the system is successful and they can be used as a reference to others. (3 figs., 2 tabs.)

  12. A Systems Engineering Approach to Quality Assurance for Aerospace Testing

    Science.gov (United States)

    Shepherd, Christena C.

    2015-01-01

    On the surface, it appears that AS91001 has little to say about how to apply a Quality Management System (QMS) to major aerospace test programs (or even smaller ones). It also appears that there is little in the quality engineering Body of Knowledge (BOK)2 that applies to testing, unless it is nondestructive examination (NDE), or some type of lab or bench testing associated with the manufacturing process. However, if one examines: a) how the systems engineering (SE) processes are implemented throughout a test program; and b) how these SE processes can be mapped to the requirements of AS9100, a number of areas for involvement of the quality professional are revealed. What often happens is that quality assurance during a test program is limited to inspections of the test article; what could be considered a manufacturing al fresco approach. This limits the quality professional and is a disservice to the programs and projects, since there are a number of ways that quality can enhance critical processes, and support efforts to improve risk reduction, efficiency and effectiveness.

  13. A Test Setup for Quality Assurance of Front End Hybrids

    CERN Document Server

    Axer, Markus; Camps, Clemens; Commichau, Volker; Flügge, Günter; Franke, Torsten; Hangarter, Klaus; Ilgin, Can; Mnich, Joachim; Niehusmann, Jan; Poettgens, Michael; Schorn, Peter; Schulte, Reiner; Struczinski, Wolfgang

    2001-01-01

    The APV Readout Control (ARC) Test Setup is a compact, cost efficient test and diagnostic tool which is suited for full operation and characterisation of FE hybrids and Si-Detector modules. This note gives an overview of the construction and the features of the test facility. Based on the ARC setup and the experience gained with one prototype FE hybrid, possible quality assurance scenarios for short and long term tests of FE hybrids are also presented.

  14. Design and Testing of the Fusion Virtual Assembly System FVAS1.0

    International Nuclear Information System (INIS)

    Pengcheng Long; Songlin Liu; Yican Wu

    2006-01-01

    Virtual assembly (VA), utilizing virtual reality (VR) technologies to plan and evaluate assembly process, retains the benefits (time-saving, inexpensive and no hazardous) of VR technologies and conquers the shortcoming of physical prototypes, such as long circle, high cost, low precision, and so on. Presented in this paper is the Fusion Virtual Assembly System FVAS 1.0 that makes possible engineering application for assemblies of large-scale complex nuclear facilities. FVAS 1.0 is designed to support the planning, evaluation and demonstration of assembly process, and training assemblers, and to work on PC (personal computer) platform. In this paper, architecture and main features of FVAS are introduced firstly. Then, design of the key sections (such as collision detection, virtual roaming) are described in detail. Finally, some successful application cases are presented. To enhance the real-time performance for large-scale nuclear facilities simulation, a policy based on separation of display scene and collision detection scene has been adopted. The display scene can be predigested to reduce the time of scene refreshment, and the collision detection performance is greatly improved by using the mature interference check ability of commercial CAD systems. Convenient observation mechanism brings more practicability. So a multi-viewpoints roaming scheme has been utilized to facilitate users' assembly operation. Users can obtain much optical information from multiple angles by switching between multi-viewpoints. The ESAT superconducting tokamak is characterized by large volume, complicated constitution and high assembly precision, e.g. the strict precision requirement in the assembly for the three tori (the tori of vacuum vessel, thermal shield, and toroidal coil). FVAS 1.0 has succeeded in demonstrating the assembly process of ESAT components. Furthermore, FVAS 1.0 has been applied to evaluate FDS-I (Fusion-Driven Sub-critical system) concept from assembly point of

  15. Neutron metrology in the fuel assemblies of a material test reactor

    International Nuclear Information System (INIS)

    Voorbraak, W.P.; Paardekoper, A.; Polle, A.N.; Freudenreich, W.E.

    1993-08-01

    Results are presented of detailed thermal and fast neutron measurements performed in all fuel and control assemblies of the HFR in Petten. The results give information about deviations of a general shape of vertical thermal and fast fluence rate distributions due to material transitions in the reactor core and different control assembly settings. Further it is demonstrated that the ratio of fast and thermal fluence rate at the various monitor positions in the assemblies give useful information for the (relative) local burn-up of the fuel. (orig.)

  16. Comparison of HYDRA predictions to temperature data from two single-assembly spent fuel heat transfer tests

    International Nuclear Information System (INIS)

    McCann, R.A.

    1986-12-01

    The HYDRA computer code was used to simulate the thermal performance of an actual and a model spent fuel assembly. The HYDRA-predicted temperatures were then compared with measured data from two single-assembly test sections. The objective of this effort was to further verify the predictive capabilities of the HYDRA code for use in assessments of the hydrothermal performance of spent fuel dry storage systems. After HYDRA has been adequately evaluated and validated, the code will be documented to permit design and licensing safety analyses

  17. Development testing of high temperature bearings for SP-100 control drive assemblies

    Science.gov (United States)

    Dalcher, Alfred W.; Kjaer-Olsen, Christian G.; Martinez, Carlos; Ogawa, Stanley Y.; Springer, Dwight R.; Yaspo, Robert

    1992-01-01

    Initial phases of two distinct SP-100 control drive assembly bearing test programs were successfully completed at elevated temperature in vacuum. The first was for the reflector drive line spherical self-aligning bearings. Each bearing consisted of a carbon-graphite ball mounted on an aluminum oxide-coated Ta-10%W shaft, captured by an aluminum oxide-coated Ta-10%W socket. One set of these bearings was exposed to temperatures up to 1180K (1665°F) at 1.33×10-6 Pa (1×10-8 torr) and subjected to 38000 cycles of motion. Friction coefficients were found to be between 0.11 and 0.25 over the full range of operation. Overall performance of the bearings was excellent, with only slight wear observed. The second test program was for the safety rod slider bearing. Zirconium carbide coated Nb-1%Zr bearings pads were stroked inside a molybdenum tube at temperatures up to 1422 K (2100°F) at ˜1.33×10-6 Pa with a normal load of 1.02 Kg between each sliding surface. Coefficients of sliding friction were found to increase from 0.90 at 293 K to 1.20 at 1422 K prior to high temperature dwells. Results were consistent over the range of stroke velocities; 5.1 to 51 mm (0.2 to 2.0 inches) per second. Following dwells of 92, 72, and 110 hours at 1422 K, static friction coefficients as high as 5.4 were observed prior to initiation of sliding, after which sliding friction coefficients of ˜1.6 were seen. Breakaway forces were well within the actuator design limits.

  18. Structured flowcharts for control logic specification in the Tritium Systems Test Assembly

    International Nuclear Information System (INIS)

    Nielson, C.W.; Claborn, G.W.

    1983-01-01

    The Tritium Systems Test Assembly (TSTA) contains several subsystems employing sophisticated chemical and physical processes to purify, transport, and capture the isotopes of hydrogen. The ultimate responsibility for the correct and safe operation of these subsystems lies with their designers. However, the logic is implemented in a computer system with program control. A means to insure unambiguous specification of the control logic in a form understandable to both the non-programming designers and the software staff was required. The computer programs are written in RATFOR, a language providing clear control structures and powerful symbol definition facilities. However, the actual code was considered unsatisfactory as a means of primary specification by the non-programming designers. On the other hand, simple English language descriptions of the desired behavior were not precise enough to insure correctness. Experimentation with traditional flowcharts proved that they were more difficult to follow than the RATFOR code. On the other hand, the use of structured flowcharts derived from those introduced by Nassi and Shneidermanl have proven to be very powerful. Using simple geometric forms for the basic control structures such as loops and conditional tests, and by using expansion rather than connection as the means of reducing any flowchart to a single page, a specification that is both understandable and precise has been obtained. A computer code automates the production and modification of these flowcharts. Combining these flowcharts with primitive subroutines which hide most of the details of control implementation has provided an effective medium for algorithm specification and validation. Examples of the flowcharts and the language used to specify them will be given

  19. Quality assurance and functionality tests on electrical components during the ATLAS IBL production

    International Nuclear Information System (INIS)

    Jentzsch, J

    2013-01-01

    To improve performance of the ATLAS inner tracker, a fourth Pixel layer, called the Insertable B-layer (IBL), will be installed in 2014 on a new beam pipe. A new read out chip generation, FE-I4, has been developed and two different sensor designs, a rather conventional planar and a 3D design, have been flip chipped to these front ends. New staves holding new stave and module flex circuits have been developed as well. Therefore, a production QA test bench has been established to test all production staves before integration with the new beam pipe. This setup combines former ATLAS Pixel services and a new readout system, namely the RCE (Reconfigurable Cluster Element) system developed at SLAC. With this setup all production staves will be tested to ensure the installation of only those staves which fulfill the IBL criteria. Quality assurance measurements under cleanroom conditions, including temperature and humidity control, are performed on the individual components during the various production steps of the IBL, namely connectivity as well as electrical tests and signal probing on individual parts and assembled subsystems. The pre-assembly QC procedures, the capabilities of the stave qualification setup, and recent results from testing a prototype stave are presented and discussed.

  20. Quality assurance and functionality tests on electrical components during the ATLAS IBL production

    Science.gov (United States)

    Jentzsch, J.

    2013-02-01

    To improve performance of the ATLAS inner tracker, a fourth Pixel layer, called the Insertable B-layer (IBL), will be installed in 2014 on a new beam pipe. A new read out chip generation, FE-I4, has been developed and two different sensor designs, a rather conventional planar and a 3D design, have been flip chipped to these front ends. New staves holding new stave and module flex circuits have been developed as well. Therefore, a production QA test bench has been established to test all production staves before integration with the new beam pipe. This setup combines former ATLAS Pixel services and a new readout system, namely the RCE (Reconfigurable Cluster Element) system developed at SLAC. With this setup all production staves will be tested to ensure the installation of only those staves which fulfill the IBL criteria. Quality assurance measurements under cleanroom conditions, including temperature and humidity control, are performed on the individual components during the various production steps of the IBL, namely connectivity as well as electrical tests and signal probing on individual parts and assembled subsystems. The pre-assembly QC procedures, the capabilities of the stave qualification setup, and recent results from testing a prototype stave are presented and discussed.

  1. Formation of high-quality self-assembled monolayers of conjugated dithiols on gold : Base matters

    NARCIS (Netherlands)

    Valkenier, Hennie; Huisman, Everardus H.; Hal, Paul A. van; de Leeuw, Dagobert; Chiechi, Ryan C.; Hummelen, Jan C.

    2011-01-01

    This Article reports a systematic study on the formation of self-assembled monolayers (SAMs) of conjugated molecules for molecular electronic (ME) devices. We monitored the deprotection reaction of acetyl protected dithiols of oligophenylene ethynylenes (OPEs) in solution using two different bases

  2. Status of the in-pile test of HCPB pebble-bed assemblies in the HFR Petten

    Energy Technology Data Exchange (ETDEWEB)

    Laan, J.G. van der; Fokkens, J.H.; Hofmans, H.E.; Jong, M.; Magielsen, A.J.; Pijlgroms, B.J.; Stijkel, M.P. [NRG, Petten (Netherlands); Conrad, R. [JRC, Inst. for Energy, Petten (Netherlands); Malang, S.; Reimann, J. [FZK, Karlsruhe (Germany); Roux, N. [CEA Saclay (France)

    2002-06-01

    In the framework of developing the helium cooled pebble-bed (HCPB) blanket an irradiation test of pebble-bed assemblies is prepared at the HFR Petten. The test objective is to concentrate on the effect of neutron irradiation on the thermal-mechanical behaviour of the HCPB breeder pebble-bed at DEMO representative levels of temperature and defined thermal-mechanical loads. The basic test elements are EUROFER-97 cylinders with a horizontal bed of ceramic breeder pebbles sandwiched between two beryllium beds. The pebble beds are separated by EUROFER-97 steel plates. The heat flow is managed such as to have a radial temperature distribution in the ceramic breeder pebble-bed as flat as reasonably possible. The paper reports on the project status, and presents the results of pre-tests, material characteristics, the manufacturing of the pebble-bed assemblies, and the nuclear and thermo-mechanical loading parameters. (orig.)

  3. Direct current linear measurement sub-assembly data and test methods. Nuclear electronic equipment for control and monitoring panel

    International Nuclear Information System (INIS)

    1977-12-01

    The M.C.H./M.E.N.T.3 document is concerned with sub-assemblies intended for measuring on a linear scale the neutron fluence rate or radiation dose rate when connected with nuclear detectors working in current. The symbols used are described. Some definitions and a bibliography are given. The main characteristics of direct current linear measurement sub-assemblies are then described together with corresponding test methods. This type of instrument indicates on a linear scale the level of a direct current applied to its input. The document reviews linear sub-assemblies for general purpose applications, difference amplifiers for monitoring, and averaging amplifiers. The document is intended for electronics manufacturers, designers, persons participating in acceptance trials and plant operators [fr

  4. Analysis and results of a hydrogen-moderated isotope production assembly in the Fast Flux Test Facility

    International Nuclear Information System (INIS)

    Wootan, D.W.; Rawlins, J.A.; Carter, L.L.; Brager, H.R.; Schenter, R.E.

    1989-01-01

    This paper reports on a cobalt test assembly containing yttrium hydride pins for neutron moderation irradiated in the Fast Flux Test Facility (FFTF) during cycle 9A for 137.7 equivalent full-power days at a power level of 291 MW. The 36 test pins consisted of a batch of 32 pins containing cobalt metal used to produce 60 Co and a set of four pins with europium oxide to produce 153 Gd, a radioisotope used in detection of the bone disease osteoporosis. Postirradiation examination of the cobalt pins determined the 60 Co production to be predictable to an accuracy of ∼ 5%. The measured 60 Co spatially distributed concentrations were within 20% of the calculated concentrations. The assembly average 60 Co measured activity was 4% less than the calculated value. The europium oxide pins were gamma scanned for the europium isotopes 152 Eu and 154 Eu to an absolute accuracy of ≅ 10%. The measured europium radioisotope and 153 Gd concentrations were within 20% of calculated values. The hydride assembly performed well and is an excellent vehicle for many FFTF isotope production applications. The results also demonstrate the accuracy of the calculational methods developed by the Westinghouse Hanford Company for predicting isotope production rates in this type of assembly

  5. European wind turbine testing procedure developments. Task 2: Power quality

    DEFF Research Database (Denmark)

    Sørensen, Poul Ejnar; Friis Pedersen, Troels; Gerdes, G.

    2001-01-01

    The present report describes the work done in the power quality subtask of the European Wind Turbine Testing Procedure Developments project funded by the EU SMT program. The objective of the power quality subtask has been to make recommendations andprovide background for new standards...... for measurement and testing of wind turbine power quality. The focus in the work has been to support the ongoing standardisation work in IEC with a new standard IEC61400-21 for measurement and assessment of powerquality characteristics of grid connected wind turbines. The work has also been based on the power...... quality measuremnet procedure in the Measnet cooperation of European test stations for wind turbines. The first working item of the project has been toverify the state of the art of the measurement procedures by analyses and comparisons of the measurements and data processing software of the participating...

  6. The effect of swelling in Inconel 600 on the performance of FFTF [Fast Flux Test Facility] reflector assemblies

    International Nuclear Information System (INIS)

    Makenas, B.J.; Trenchard, R.G.; Hecht, S.L.; McCarthy, J.M.; Garner, F.A.

    1986-02-01

    The Fast Flux Test Facility (FFTF) is designed with non-fueled outer row assemblies, each of which consists of a stack of Inconel 600 blocks penetrated by 316 stainless steel (SS) coolant tubes. These assemblies act as a radial neutron reflector and as a straight but flexible core boundary. During an FFTF refueling outage it was observed that the degree of difficulty in withdrawing an outer row driver fuel assembly was a function of the peak fast fluence of neighboring reflector assemblies. It was subsequently determined through various postirradiation examinations that the reflector assemblies were both bowed and stiff. Measurements of the individual Inconel 600 blocks indicated that the blocks had distorted into a trapezoidal cross section due to differential swelling of Inconel 600 in a steep radial flux gradient. Immersion density results indicate greater irradiation induced volumetric swelling than any previously reported data or correlation for Inconel 600 at equivalent fast fluence. The Inconel 600 swelled approximately the same amount as the SA 316 SS reflector components. Transmission electron microscopy studies on the Inconel blocks and swelling measurements on related materials have been performed and these data have been related to the performance of the reflector materials

  7. Current quality assurance concepts and considerations for quality control of in-clinic biochemistry testing.

    Science.gov (United States)

    Lester, Sally; Harr, K E; Rishniw, Mark; Pion, Paul

    2013-01-15

    Quality assurance is an implied concept inherent in every consumer's purchase of a product or service. In laboratory testing, quality assurance encompasses preanalytic (sampling, transport, and handling prior to testing), analytic (measurement), and postanalytic (reporting and interpretation) factors. Quality-assurance programs require that procedures are in place to detect errors in all 3 components and that the procedures are characterized by both documentation and correction of errors. There are regulatory bodies that provide mandatory standards for and regulation of human medical laboratories. No such regulations exist for veterinary laboratory testing. The American Society for Veterinary Clinical Pathology (ASVCP) Quality Assurance and Laboratory Standards Committee was formed in 1996 in response to concerns of ASVCP members about quality assurance and quality control in laboratories performing veterinary testing. Guidelines for veterinary laboratory testing have been developed by the ASVCP. The purpose of this report was to provide an overview of selected quality-assurance concepts and to provide recommendations for quality control for in-clinic biochemistry testing in general veterinary practice.

  8. Visual Perception-Based Statistical Modeling of Complex Grain Image for Product Quality Monitoring and Supervision on Assembly Production Line.

    Directory of Open Access Journals (Sweden)

    Jinping Liu

    Full Text Available Computer vision as a fast, low-cost, noncontact, and online monitoring technology has been an important tool to inspect product quality, particularly on a large-scale assembly production line. However, the current industrial vision system is far from satisfactory in the intelligent perception of complex grain images, comprising a large number of local homogeneous fragmentations or patches without distinct foreground and background. We attempt to solve this problem based on the statistical modeling of spatial structures of grain images. We present a physical explanation in advance to indicate that the spatial structures of the complex grain images are subject to a representative Weibull distribution according to the theory of sequential fragmentation, which is well known in the continued comminution of ore grinding. To delineate the spatial structure of the grain image, we present a method of multiscale and omnidirectional Gaussian derivative filtering. Then, a product quality classifier based on sparse multikernel-least squares support vector machine is proposed to solve the low-confidence classification problem of imbalanced data distribution. The proposed method is applied on the assembly line of a food-processing enterprise to classify (or identify automatically the production quality of rice. The experiments on the real application case, compared with the commonly used methods, illustrate the validity of our method.

  9. Visual Perception-Based Statistical Modeling of Complex Grain Image for Product Quality Monitoring and Supervision on Assembly Production Line.

    Science.gov (United States)

    Liu, Jinping; Tang, Zhaohui; Zhang, Jin; Chen, Qing; Xu, Pengfei; Liu, Wenzhong

    2016-01-01

    Computer vision as a fast, low-cost, noncontact, and online monitoring technology has been an important tool to inspect product quality, particularly on a large-scale assembly production line. However, the current industrial vision system is far from satisfactory in the intelligent perception of complex grain images, comprising a large number of local homogeneous fragmentations or patches without distinct foreground and background. We attempt to solve this problem based on the statistical modeling of spatial structures of grain images. We present a physical explanation in advance to indicate that the spatial structures of the complex grain images are subject to a representative Weibull distribution according to the theory of sequential fragmentation, which is well known in the continued comminution of ore grinding. To delineate the spatial structure of the grain image, we present a method of multiscale and omnidirectional Gaussian derivative filtering. Then, a product quality classifier based on sparse multikernel-least squares support vector machine is proposed to solve the low-confidence classification problem of imbalanced data distribution. The proposed method is applied on the assembly line of a food-processing enterprise to classify (or identify) automatically the production quality of rice. The experiments on the real application case, compared with the commonly used methods, illustrate the validity of our method.

  10. Best Practices: Power Quality and Integrated Testing at JSC

    Science.gov (United States)

    Davis, Lydia

    2018-01-01

    This presentation discusses Best Practices for Power Quality and Integrated Testing at JSC in regards to electrical systems. These high-level charts include mostly generic information; however, a specific issue is discussed involving flight hardware that could have been discovered prior to flight with an integrated test.

  11. System Quality Management in Software Testing Laboratory that Chooses Accreditation

    Directory of Open Access Journals (Sweden)

    Yanet Brito R.

    2013-12-01

    Full Text Available The evaluation of software products will reach full maturity when executed by the scheme and provides third party certification. For the validity of the certification, the independent laboratory must be accredited for that function, using internationally recognized standards. This brings with it a challenge for the Industrial Laboratory Testing Software (LIPS, responsible for testing the products developed in Cuban Software Industry, define strategies that will permit it to offer services with a high level of quality. Therefore it is necessary to establish a system of quality management according to NC-ISO/IEC 17025: 2006 to continuously improve the operational capacity and technical competence of the laboratory, with a view to future accreditation of tests performed. This article discusses the process defined in the LIPS for the implementation of a Management System of Quality, from the current standards and trends, as a necessary step to opt for the accreditation of the tests performed.

  12. Engineering scale tests of mechanical disassembly and short stroke shearing systems for FBR fuel assembly

    International Nuclear Information System (INIS)

    Higuchi, Hidetoshi; Kitagaki, Toru; Koizumi, Kenji; Hirano, Hiroyasu; Takeuchi, Masayuki; Washiya, Tadahiro; Kawabe, Yukinari; Kobayashi, Tsuguyuki

    2011-01-01

    Japan Atomic Energy Agency (JAEA) and The Japan Atomic Power Company (JAPC) have been developing an advanced head-end process based on mechanical disassembly and short stroke shearing systems as a part of Fast Reactor Cycle Technology Development (FaCT). Fuel pins for a fast reactor are installed within a hexagonal shaped wrapper tube made of stainless steel. In order to reprocess the fast reactor fuel pins, they must be removed from the wrapper tube and transported to the shearing system without failure. In addition, the advanced aqueous reprocessing process, called 'NEXT' (New Extraction System for TRU Recovery) process requires a solution of the spent fuel with relatively high concentration (500g/L). JAEA and JAPC have developed the mechanical disassembly and the short stroke shearing technology which is expected to make fragmented fuel to satisfy these requirements. This paper reports the results of engineering scale tests on the mechanical disassembly and short stroke shearing systems. These tests were carried out with simulated FBR fuel assembly and removed pins. The mechanical cutting method has been developed to avoid fuel pin failure during disassembly operation. The cutting process is divided into two modes, so called 'slit-cut' for cutting the wrapper tube and 'crop-cut' for the end plug region of the fuel pin bundle. In the slit-cut mode, the depth of cutting was automatically controlled based on the calculated wastage of the cutting tool and deformation of the wrapper tube which had been measured before the cutting. This procedure was confirmed to minimize the fuel pin failure which was hard to prevent in the case of laser cutting. The cutting speed was also controlled automatically by the electric current of the cutting motor to lower the load of the cutting tool. The removed fuel pins were transported to the shearing machine, whose fuel shearing magazine width was set to be narrow to realize the suitable configuration for the short stroke shearing

  13. Quality testing as a reserve for rationalization measures

    International Nuclear Information System (INIS)

    Babic, H.G.

    1979-01-01

    The increase in large-scale planning activities and their realization in all fields of quality testing as opposed to the requirements for a reduction of costs emphasizes the necessity of rationaling measures. Especially during the planning phases there are a number of possibilities for solving this problem: the determination of reference dates for production devices based on the preparation of dates with regard to machines and testing, the assignment of the testing frequency in dependence of the quotient from deviations in production and characteristics tolerances, the application of methods of operation planning following different priority rules. Apart from already existing systems for normal and computeraided planning of testing material application by the help of which the most optimal testing material is selected for certain testing jobs systematic representations and programs for the planning of the testing procedure and the testing precision will enrich the joint complex of the organization of testing procedures. (orig./RW) [de

  14. Dispositional optimism and sleep quality: a test of mediating pathways.

    Science.gov (United States)

    Uchino, Bert N; Cribbet, Matthew; de Grey, Robert G Kent; Cronan, Sierra; Trettevik, Ryan; Smith, Timothy W

    2017-04-01

    Dispositional optimism has been related to beneficial influences on physical health outcomes. However, its links to global sleep quality and the psychological mediators responsible for such associations are less studied. This study thus examined if trait optimism predicted global sleep quality, and if measures of subjective well-being were statistical mediators of such links. A community sample of 175 participants (93 men, 82 women) completed measures of trait optimism, depression, and life satisfaction. Global sleep quality was assessed using the Pittsburgh Sleep Quality Index. Results indicated that trait optimism was a strong predictor of better PSQI global sleep quality. Moreover, this association was mediated by depression and life satisfaction in both single and multiple mediator models. These results highlight the importance of optimism for the restorative process of sleep, as well as the utility of multiple mediator models in testing distinct psychological pathways.

  15. Standards for measurements and testing of wind turbine power quality

    Energy Technology Data Exchange (ETDEWEB)

    Soerensen, P [Risoe National Lab., Roskilde (Denmark); Gerdes, G; Klosse, R; Santjer, F [DEWI, Wilhelmshaven (Germany); Robertson, N; Davy, W [NEL, Glasgow (United Kingdom); Koulouvari, M; Morfiadakis, E [CRES, Pikermi (Greece); Larsson, Aa [Chalmers Univ. of Technology, Goeteborg (Sweden)

    1999-03-01

    The present paper describes the work done in power quality sub-task of the project `European Wind Turbine Testing Procedure Developments` funded by the EU SMT program. The objective of the power quality sub-task has been to make analyses and new recommendation(s) for the standardisation of measurement and verification of wind turbine power quality. The work has been organised in three major activities. The first activity has been to propose measurement procedures and to verify existing and new measurement procedures. This activity has also involved a comparison of the measurements and data processing of the participating partners. The second activity has been to investigate the influence of terrain, grid properties and wind farm summation on the power quality of wind turbines with constant rotor speed. The third activity has been to investigate the influence of terrain, grid properties and wind farm summation on the power quality of wind turbines with variable rotor speed. (au)

  16. Pre-test nondestructive examination data summary report on Turkey Point spent fuel assemblies D01, D04 and D06 for the climax-spent fuel test

    International Nuclear Information System (INIS)

    Davis, R.B.

    1981-01-01

    Fuel assembly sip testing conducted at Turkey Point and Battelle Columbus Laboratories (BCL) confirmed no leaking rods were among the thirteen fuel assemblies included in the Climax-Spent Fuel Test. A detailed nondestructive examination was conducted on three of the thirteen assemblies. Fuel assembly lengths and widths averaged 153.6 inches and 8.3 inches, respectively. The assemblies weighed 1459 +- 3 lbs. Total neutron flux measured at the fuel column midplane was 1.06 x 10 4 N/cm 2 /s with an average neutron energy of 1.4 MeV. Gamma dose rates were measured axially and vertically to the fuel column with maximum contact dose rate of 9.52 x 10 4 R/h. Twenty rods underwent detailed rod nondestructive examination. Rod lengths and weights averaged 152.5 inches and 6.82 lb, respectively. Spiral profilometry scans showed the maximum ovality for the twenty rods was 0.0105 inch with average rod diameters ranging from 0.4201 inch to 0.4211 inch. Extensive ridging from pellet cladding interaction was evident over most of the length on all rods. Gamma scan results showed no cesium peaking and no unusually large pellet to pellet gaps. Approximate 10% gamma activity depressions were found at the grid spacer locations. Several areas were identified as locations with an internal anomaly using eddy current results. Fifteen rods were reinserted into the three fuel assemblies at the completion of the nondestructive examinations. Five rods remained at BCL for destructive characterization

  17. Recent Progress toward Microfluidic Quality Control Testing of Radiopharmaceuticals

    Directory of Open Access Journals (Sweden)

    Noel S. Ha

    2017-11-01

    Full Text Available Radiopharmaceuticals labeled with short-lived positron-emitting or gamma-emitting isotopes are injected into patients just prior to performing positron emission tomography (PET or single photon emission tomography (SPECT scans, respectively. These imaging modalities are widely used in clinical care, as well as in the development and evaluation of new therapies in clinical research. Prior to injection, these radiopharmaceuticals (tracers must undergo quality control (QC testing to ensure product purity, identity, and safety for human use. Quality tests can be broadly categorized as (i pharmaceutical tests, needed to ensure molecular identity, physiological compatibility and that no microbiological, pyrogenic, chemical, or particulate contamination is present in the final preparation; and (ii radioactive tests, needed to ensure proper dosing and that there are no radiochemical and radionuclidic impurities that could interfere with the biodistribution or imaging. Performing the required QC tests is cumbersome and time-consuming, and requires an array of expensive analytical chemistry equipment and significant dedicated lab space. Calibrations, day of use tests, and documentation create an additional burden. Furthermore, in contrast to ordinary pharmaceuticals, each batch of short-lived radiopharmaceuticals must be manufactured and tested within a short period of time to avoid significant losses due to radioactive decay. To meet these challenges, several efforts are underway to develop integrated QC testing instruments that automatically perform and document all of the required tests. More recently, microfluidic quality control systems have been gaining increasing attention due to vastly reduced sample and reagent consumption, shorter analysis times, higher detection sensitivity, increased multiplexing, and reduced instrumentation size. In this review, we describe each of the required QC tests and conventional testing methods, followed by a

  18. Pharmacists performing quality spirometry testing: an evidence based review.

    Science.gov (United States)

    Cawley, Michael J; Warning, William J

    2015-10-01

    The scope of pharmacist services for patients with pulmonary disease has primarily focused on drug related outcomes; however pharmacists have the ability to broaden the scope of clinical services by performing diagnostic testing including quality spirometry testing. Studies have demonstrated that pharmacists can perform quality spirometry testing based upon international guidelines. The primary aim of this review was to assess the published evidence of pharmacists performing quality spirometry testing based upon American Thoracic Society/European Respiratory Society (ATS/ERS) guidelines. In order to accomplish this, the description of evidence and type of outcome from these services were reviewed. A literature search was conducted using five databases [PubMed (1946-January 2015), International Pharmaceutical Abstracts (1970 to January 2015), Cumulative Index of Nursing and Allied Health Literature, Cochrane Central Register of Controlled Trials and Cochrane Database of Systematic Reviews] with search terms including pharmacy, spirometry, pulmonary function, asthma or COPD was conducted. Searches were limited to publications in English and reported in humans. In addition, Uniform Resource Locators and Google Scholar searches were implemented to include any additional supplemental information. Eight studies (six prospective multi-center trials, two retrospective single center studies) were included. Pharmacists in all studies received specialized training in performing spirometry testing. Of the eight studies meeting inclusion and exclusion criteria, 8 (100%) demonstrated acceptable repeatability of spirometry testing based upon standards set by the ATS/ERS guidelines. Acceptable repeatability of seven studies ranged from 70 to 99% consistent with published data. Available evidence suggests that quality spirometry testing can be performed by pharmacists. More prospective studies are needed to add to the current evidence of quality spirometry testing performed by

  19. Interim guidance risk assessment of the device assembly facility at the Nevada test site

    International Nuclear Information System (INIS)

    Altenbach, T.J.

    1996-05-01

    The risks of plutonium dispersal and/or high explosive detonation from nuclear explosive operations at the Device Assembly Facility were examined in accordance with DOE Order 5610.11 and the Interim Guidance. The assessment consisted of a qualitative task and hazards analysis, and a quantitative risk screening. Results are displayed on risk matrices for the major types of operations. Most accident scenarios were considered to have Low risk; a few scenarios have Moderate risk; and none have High risk. The highest risk scenarios (Moderate category) consist of a high explosive detonation during assembly operations in a cell, with bare conventional high explosive surrounding the pit

  20. Relationship of psychosocial work factors and health-related quality of life in male automotive assembly workers in Malaysia.

    Science.gov (United States)

    Edimansyah, Bin Abdin; Rusli, Bin Nordin; Naing, Lin; Mohamed Rusli, Bin Abdullah; Winn, Than

    2007-06-01

    The present study investigates the relationship between psychosocial work factors and health-related quality of life (HRQOL) in male automotive assembly plant workers in Malaysia. A total of 728 male workers were recruited in March-July 2005 from 2 major automotive assembly plants in Selangor and Pahang. In this cross-sectional study, information on socio-demography, psychosocial work factors using the 97-item Job Content Questionnaire (JCQ) and an abbreviated 26-item version of the World Health Organization Quality of Life-Brief Version (WHOQOL-BREF) questionnaire containing 4 domains (physical health, psychological, social relationship, and environment) was self-administered to all workers involved. The prevalence of reported good or very good overall HRQOL and general health was 64.9% and 53.7%, respectively. Multiple linear regression analysis indicated that created skill was positively associated with physical health and psychological domains; whilst, skill discretion was positively associated with social relationship and environment domains. Social support was positively associated with physical health and environment domains; whilst, co-worker support was positively associated with psychological and social relationship domains. Job insecurity and hazardous condition were negatively associated with all domains, whilst psychological job demands was negatively associated with the environment domain of HRQOL.

  1. Synthesis of high quality single-walled carbon nanotubes via a catalytic layer reinforced by self-assembled monolayers

    International Nuclear Information System (INIS)

    Adhikari, Prashanta Dhoj; Song, Wooseok; Cha, Myoung-Jun; Park, Chong-Yun

    2013-01-01

    This work reports the synthesis of high quality single-walled carbon nanotubes (SWCNT) using a catalytic layer reinforced by self-assembled monolayers (SAM). Amine-SAM was introduced on a SiO 2 /Si substrate and then an iron nanoparticles solution was dropped on the substrate by spin-coating. This catalytic template was used to grow carbon nanotubes by chemical vapor deposition and the synthesized SWCNT were observed to be prominent, based on the size distribution. Highly dense SWCNT with a diameter of about 1.1-1.2 nm were produced at 800-850 °C. Moreover, the diameter distribution of the SWCNT was more selective at a growth temperature of 900 °C. These findings provide important insights for a SAM support layer that can play the role as a restriction for the agglomeration of iron catalyst and is promising for the synthesis of high quality SWCNT. - Highlights: • Fe nanoparticles on self-assembled monolayers (SAM) containing template is underlined. • Its catalytic behavior to synthesis single-walled carbon nanotubes is studied. • The role of SAM on catalytic template is explored

  2. Study of the thermo-mechanical performances of the IFMIF-EVEDA Lithium Test Loop target assembly

    Energy Technology Data Exchange (ETDEWEB)

    Di Maio, P.A., E-mail: dimaio@din.unipa.it [Dipartimento dell' Energia, Universita di Palermo, Viale delle Scienze, 90128 Palermo (Italy); Arena, P.; Bongiovi, G. [Dipartimento dell' Energia, Universita di Palermo, Viale delle Scienze, 90128 Palermo (Italy); Giammusso, R.; Micciche, G.; Tincani, A. [ENEA C. R. Brasimone, 40032 Camugnano, Bologna (Italy)

    2012-08-15

    Highlights: Black-Right-Pointing-Pointer IFMIF-EVEDA target assembly thermo-mechanical behavior has been investigated. Black-Right-Pointing-Pointer Finite element method has been followed and a commercial code has been used. Black-Right-Pointing-Pointer Nominal, design and pressure test steady state scenarios and start-up transient conditions have been investigated. Black-Right-Pointing-Pointer Steady state results have shown that back-plate yielding may occur only under the design scenario. Black-Right-Pointing-Pointer Transient analysis has indicated that TA start-up lasts for {approx}60 h. - Abstract: Within the framework of the IFMIF R and D program and in close cooperation with ENEA-Brasimone, at the Department of Energy of the University of Palermo a research campaign has been launched to investigate the thermo-mechanical behavior of the target assembly under both steady state and start-up transient conditions. A theoretical approach based on the finite element method (FEM) has been followed and a well-known commercial code has been adopted. A realistic 3D FEM model of the target assembly has been set-up and optimized by running a mesh independency analysis. A proper set of loads and boundary conditions, mainly concerned with radiation heat transfer between the target assembly external walls and the inner walls of its containment vessel, have been considered and the target assembly thermo-mechanical behavior under nominal, design and pressure test steady state scenarios and start-up transient conditions has been investigated. Results are herewith reported and discussed.

  3. Optimization of a readout board for mass assembly and light yield measurements with a cosmic ray test stand

    Energy Technology Data Exchange (ETDEWEB)

    Chau, Phi [Johannes Gutenberg-Universitaet Mainz, Institut fuer Physik (Germany); Collaboration: CALICE-D-Collaboration

    2016-07-01

    We have built a readout board prototype, equipped with SiPMs, scintillators and readout electronics for an highly granular calorimeter. The design was optimized for mass assembly due to about 8 million channels in the final detector. The prototype showed good performance in several test beams and in a cosmic ray test stand, which was built to characterize the MIP response of these kinds of boards. We show an overview of the cosmic ray test stand and measurement results for the readout board and plans for an improved 2nd generation prototype.

  4. ITC Guidelines on Quality Control in Scoring, Test Analysis, and Reporting of Test Scores

    Science.gov (United States)

    Allalouf, Avi

    2014-01-01

    The Quality Control (QC) Guidelines are intended to increase the efficiency, precision, and accuracy of the scoring, analysis, and reporting process of testing. The QC Guidelines focus on large-scale testing operations where multiple forms of tests are created for use on set dates. However, they may also be used for a wide variety of other testing…

  5. Field test and evaluation of the IAEA coincidence collar for the measurement of unirradiated BWR fuel assemblies

    International Nuclear Information System (INIS)

    Menlove, H.O.; Keddar, A.

    1982-12-01

    The neutron coincidence counter has been field tested and evaluated for the measurement of boiling-water-reactor (BWR) fuel assemblies at the ASEA-ATOM Fuel Fabrication Facility. The system measures the 235 U content per unit length of full fuel assemblies using neutron interrogation and coincidence counting. The 238 U content is measured in the passive mode without the AmLi neutron interrogatioin source. The field tests included both standard production movable fuel rods to investigate enrichment and absorber variations. Results gave a response standard deviation of 0.9% for the active case and 2.1% for the passive case in 1000-s measurement times. 10 figures, 2 tables

  6. Development of a bellows assembly with RF-shield for KEKB II: abrasion and pumping down tests

    International Nuclear Information System (INIS)

    Suetsugu, Yusuke; Kanazawa, Ken-ichi; Kawahara, Masaharu; Harada, Yosuke; Kaneko, Motosada

    1997-01-01

    A bellows assembly with RF-shield as been designed and developed for the KEK B-factory (KEKB). The RF-shield is a usual finger-type but has special spring-fingers to press contact-fingers (shield-fingers) surely onto inner tube (beam tube). In a chain of design studies an abrasion test of the contact-fingers was performed in vacuum. A quantity of generated metal particles was estimated and expected to have little harm on the beam lifetime if the inner tube is coated with silver. The gas desorption rate and the residual gas components of the bellows assembly were also measured as a final bench test. The gas desorption rate of 1 - 1.5x10 -10 Pa·l/s/cm 2 was obtained after a bake at 150degC for 24 hours. (author)

  7. Newnes electronics assembly handbook

    CERN Document Server

    Brindley, Keith

    2013-01-01

    Newnes Electronics Assembly Handbook: Techniques, Standards and Quality Assurance focuses on the aspects of electronic assembling. The handbook first looks at the printed circuit board (PCB). Base materials, basic mechanical properties, cleaning of assemblies, design, and PCB manufacturing processes are then explained. The text also discusses surface mounted assemblies and packaging of electromechanical assemblies, as well as the soldering process. Requirements for the soldering process; solderability and protective coatings; cleaning of PCBs; and mass solder/component reflow soldering are des

  8. A Solar Powered Wireless Computer Mouse: Design, Assembly and Preliminary Testing of 15 Prototypes

    NARCIS (Netherlands)

    van Sark, W.G.J.H.M.; Reich, N.H.; Alsema, E.A.; Netten, M.P.; Veefkind, M.; Silvester, S.; Elzen, B.; Verwaal, M.

    2007-01-01

    The concept and design of a solar powered wireless computer mouse has been completed, and 15 prototypes have been successfully assembled. After necessary cutting, the crystalline silicon cells show satisfactory efficiency: up to 14% when implemented into the mouse device. The implemented voltage

  9. [Testing methods for seed quality of Bletilla striata].

    Science.gov (United States)

    Zhang, Zhi-Hui; Liu, Da-Hui; Zhu, Xin-Yan; Ji, Peng-Zhang; Wang, Li; Shi, Ya-Na; Ma, Cong-Ji

    2016-06-01

    In order to provide a basis for establishing seed testing rules and seed quality standard of Bletilla striata, the seed quality of B.striata from different producing area was measured referring to the Rules for Agricultural Seed Testing(GB/T 3543-1995).The results showed that the seeds of B.striata passed through 20-mesh sieve for purity analysis.The weight of seeds was measured by 1000-seed method and the water content was measured at the higher temperature (133±2) ℃ for 3 hours.The seeds were cultured on the wet filter paper at 30 ℃ for 4-20 days in light for germination testing.The method of testing seed viability was that seeds were dipped into 1% TTC solution for 7 hours at temperature of 40 ℃. Copyright© by the Chinese Pharmaceutical Association.

  10. ROSA-V large scale test facility (LSTF) system description for the third and fourth simulated fuel assemblies

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Mitsuhiro; Nakamura, Hideo; Ohtsu, Iwao [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment] [and others

    2003-03-01

    The Large Scale Test Facility (LSTF) is a full-height and 1/48 volumetrically scaled test facility of the Japan Atomic Energy Research Institute (JAERI) for system integral experiments simulating the thermal-hydraulic responses at full-pressure conditions of a 1100 MWe-class pressurized water reactor (PWR) during small break loss-of-coolant accidents (SBLOCAs) and other transients. The LSTF can also simulate well a next-generation type PWR such as the AP600 reactor. In the fifth phase of the Rig-of-Safety Assessment (ROSA-V) Program, eighty nine experiments have been conducted at the LSTF with the third simulated fuel assembly until June 2001, and five experiments have been conducted with the newly-installed fourth simulated fuel assembly until December 2002. In the ROSA-V program, various system integral experiments have been conducted to certify effectiveness of both accident management (AM) measures in beyond design basis accidents (BDBAs) and improved safety systems in the next-generation reactors. In addition, various separate-effect tests have been conducted to verify and develop computer codes and analytical models to predict non-homogeneous and multi-dimensional phenomena such as heat transfer across the steam generator U-tubes under the presence of non-condensable gases in both current and next-generation reactors. This report presents detailed information of the LSTF system with the third and fourth simulated fuel assemblies for the aid of experiment planning and analyses of experiment results. (author)

  11. Higher quality of molecular testing, an unfulfilled priority: Results from external quality assessment for KRAS mutation testing in colorectal cancer.

    Science.gov (United States)

    Tembuyser, Lien; Ligtenberg, Marjolijn J L; Normanno, Nicola; Delen, Sofie; van Krieken, J Han; Dequeker, Elisabeth M C

    2014-05-01

    Precision medicine is now a key element in clinical oncology. RAS mutational status is a crucial predictor of responsiveness to anti-epidermal growth factor receptor agents in metastatic colorectal cancer. In an effort to guarantee high-quality testing services in molecular pathology, the European Society of Pathology has been organizing an annual KRAS external quality assessment program since 2009. In 2012, 10 formalin-fixed, paraffin-embedded samples, of which 8 from invasive metastatic colorectal cancer tissue and 2 artificial samples of cell line material, were sent to more than 100 laboratories from 26 countries with a request for routine KRAS testing. Both genotyping and clinical reports were assessed independently. Twenty-seven percent of the participants genotyped at least 1 of 10 samples incorrectly. In total, less than 5% of the distributed specimens were genotyped incorrectly. Genotyping errors consisted of false negatives, false positives, and incorrectly genotyped mutations. Twenty percent of the laboratories reported a technical error for one or more samples. A review of the written reports showed that several essential elements were missing, most notably a clinical interpretation of the test result, the method sensitivity, and the use of a reference sequence. External quality assessment serves as a valuable educational tool in assessing and improving molecular testing quality and is an important asset for monitoring quality assurance upon incorporation of new biomarkers in diagnostic services. Copyright © 2014 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.

  12. Does quantity generate quality? Testing the fundamental principle of brainstorming.

    Science.gov (United States)

    Muñoz Adánez, Alfredo

    2005-11-01

    The purpose of this work is to test the chief principle of brainstorming, formulated as "quantity generates quality." The study is included within a broad program whose goal is to detect the strong and weak points of creative techniques. In a sample of 69 groups, containing between 3 and 8 members, the concurrence of two commonly accepted criteria was established as a quality rule: originality and utility or value. The results fully support the quantity-quality relation (r = .893): the more ideas produced to solve a problem, the better quality of the ideas. The importance of this finding, which supports Osborn's theory, is discussed, and the use of brainstorming is recommended to solve the many open problems faced by our society.

  13. Quality Control Tests on Andrographis paniculata Nees (Family ...

    African Journals Online (AJOL)

    Purpose: To characterize the aerial parts of Andrographis paniculata, a bitter Indian herb grown in Nigeria, for the purpose of quality control. Methods: The determination of bitterness value and of various physicochemical characteristics; tests for key phytochemicals; and thin layer chromatography (TLC) of the air-dried herb, ...

  14. Quality control tests for the CMS Barrel RPCs

    International Nuclear Information System (INIS)

    Abbrescia, M.; Colaleo, A.; Guida, R.; Iaselli, G.; Loddo, F.; Maggi, M.; Marangelli, B.; Natali, S.; Nuzzo, S.; Pugliese, G.; Ranieri, A.; Romano, F.; Trentadue, R.; Cavallo, N.; Fabozzi, F.; Paolucci, P.; Piccolo, D.; Polese, G.; Sciacca, C.; Belli, G.; Necchi, M.; Ratti, S.P.; Riccardi, C.; Torre, P.; Vitulo, P.; Anguelov, T.; Genchev, V.; Panev, B.; Piperov, S.; Sultanov, G.; Vankov, P.; Dimitrov, A.; Litov, L.; Pavlov, B.; Petkov, P.

    2006-01-01

    An RPC based system will be employed for the CMS muon first level trigger. Severe quality controls and certification have been established all along the entire production chain. Procedures are briefly described and results for the acceptance percentage are given for the second part of the single gaps and double gaps production. Summary results are also reported for the full sets of tested chambers

  15. Improvement in quality testing of Braille printer output with Euclidean ...

    African Journals Online (AJOL)

    This paper focuses on quality testing of Braille printed paper using calibrated camera by detecting dots and measuring the Euclidean distances between them with equal gap, vertically and horizontally. For higher accuracy, camera calibration is essential to observe a planar checker board pattern from different distances and ...

  16. Quality Tests of Double-Sided Silicon Strip Detectors

    CERN Document Server

    Cambon, T; CERN. Geneva; Fintz, P; Guillaume, G; Jundt, F; Kuhn, C; Lutz, Jean Robert; Pagès, P; Pozdniakov, S; Rami, F; Sparavec, K; Dulinski, W; Arnold, L

    1997-01-01

    The quality of the SiO2 insulator (AC coupling between metal and implanted strips) of double-sided Silicon strip detectors has been studied by using a probe station. Some tests performed on 23 wafers are described and the results are discussed. Remark This note seems to cause problems with ghostview but it can be printed without any problem.

  17. Water Quality: A Field-Based Quality Testing Program for Middle Schools and High Schools.

    Science.gov (United States)

    Massachusetts State Water Resources Authority, Boston.

    This manual contains background information, lesson ideas, procedures, data collection and reporting forms, suggestions for interpreting results, and extension activities to complement a water quality field testing program. Information on testing water temperature, water pH, dissolved oxygen content, biochemical oxygen demand, nitrates, total…

  18. Rules of thumb to increase the software quality through testing

    Science.gov (United States)

    Buttu, M.; Bartolini, M.; Migoni, C.; Orlati, A.; Poppi, S.; Righini, S.

    2016-07-01

    The software maintenance typically requires 40-80% of the overall project costs, and this considerable variability mostly depends on the software internal quality: the more the software is designed and implemented to constantly welcome new changes, the lower will be the maintenance costs. The internal quality is typically enforced through testing, which in turn also affects the development and maintenance costs. This is the reason why testing methodologies have become a major concern for any company that builds - or is involved in building - software. Although there is no testing approach that suits all contexts, we infer some general guidelines learned during the Development of the Italian Single-dish COntrol System (DISCOS), which is a project aimed at producing the control software for the three INAF radio telescopes (the Medicina and Noto dishes, and the newly-built SRT). These guidelines concern both the development and the maintenance phases, and their ultimate goal is to maximize the DISCOS software quality through a Behavior-Driven Development (BDD) workflow beside a continuous delivery pipeline. We consider different topics and patterns; they involve the proper apportion of the tests (from end-to-end to low-level tests), the choice between hardware simulators and mockers, why and how to apply TDD and the dependency injection to increase the test coverage, the emerging technologies available for test isolation, bug fixing, how to protect the system from the external resources changes (firmware updating, hardware substitution, etc.) and, eventually, how to accomplish BDD starting from functional tests and going through integration and unit tests. We discuss pros and cons of each solution and point out the motivations of our choices either as a general rule or narrowed in the context of the DISCOS project.

  19. Project, fabrication, assembly and tests of different prototypes for CPS compound parabolic solar collectors; Projeto, fabricacao, montagem e testes de diferentes prototipos de coletores solares parabolicos compostos CPCs

    Energy Technology Data Exchange (ETDEWEB)

    Neto, Jose H.M. [Centro Federal de Educacao Tecnologica de Minas Gerais (CEFET), Belo Horizonte, MG (Brazil). Dept. de Engenharia Mecanica]. E-mail: henrique@daem.des.cefemg.br

    2000-07-01

    This work presents the results of the experiment involving the design, fabrication, assembly and tests of composite parabolic solar collectors prototypes with acceptance half-angles of 3 deg C, 6.5 deg C, 11 deg C, 14 deg C and 19.5 deg C of the tube type absorber and 14 deg C rectangular absorber. Field test were performed on all the prototypes for determination of thermal efficiency, time constants and optical efficiencies represented by the modified incidence angles. Tests were performed for the determination of the heat transfer global coefficients on each prototype. (author)

  20. Evaluation of the ceramographies of the KNK II/1 test zone fuel assembly NY-202-IA

    International Nuclear Information System (INIS)

    Geier, F.

    1983-12-01

    From the 211 fuel pins of the KNK II/1 fuel assembly NY-202-IA six intact fuel pins were selected in addition to the defective pin for destructive post-irradiation examinations in the Hot Cells of the KfK Karlsruhe. The assembly had been unloaded due to a pin failure after 192 equivalent full-power days and a maximum burnup of 5.4 %. The main aspect of these investigations was to record the fuel and fuel pin behavior and thus to allow a comparison of the status before and after irradiation. The results can also be used for comparative calculations and adaptations of existing calculational models. This report documents in detailed form the results of the fuel and fuel pin examinations [de

  1. Limited streamer chamber testing and quality evaluation in ASTRA

    International Nuclear Information System (INIS)

    Anzivino, G.; Bianco, S.; Casaccia, R.

    1991-01-01

    Limited streamer chambers are extensively used for high-energy and nuclear physics experiments in accelerator and underground laboratories. The tracking system of LVD, an underground experiment to study muons and nutrino astronomy, will use roughly 15000 limited streamer chambers and 100000 external pickup strips with digital readout electronics. In the article the different aspects of chamber operation that serve to establish a testing procedure and to define acceptance criteria for selecting reliable and long-life devices, are discussed. The procedures and the results obtained from a long-term test to evaluate streamer chamber quality, based upon a sample of 2900 items, are described. The selection tests and the long-term observations have been performed in the ASTRA laboratory, established at the Laboratori Nazionali di Frascati to carry out quality control procedures for streamer chambers on a large scale and in a controlled environment

  2. The 1993 baseline biological studies and proposed monitoring plan for the Device Assembly Facility at the Nevada Test Site

    Energy Technology Data Exchange (ETDEWEB)

    Woodward, B.D.; Hunter, R.B.; Greger, P.D.; Saethre, M.B.

    1995-02-01

    This report contains baseline data and recommendations for future monitoring of plants and animals near the new Device Assembly Facility (DAF) on the Nevada Test Site (NTS). The facility is a large structure designed for safely assembling nuclear weapons. Baseline data was collected in 1993, prior to the scheduled beginning of DAF operations in early 1995. Studies were not performed prior to construction and part of the task of monitoring operational effects will be to distinguish those effects from the extensive disturbance effects resulting from construction. Baseline information on species abundances and distributions was collected on ephemeral and perennial plants, mammals, reptiles, and birds in the desert ecosystems within three kilometers (km) of the DAF. Particular attention was paid to effects of selected disturbances, such as the paved road, sewage pond, and the flood-control dike, associated with the facility. Radiological monitoring of areas surrounding the DAF is not included in this report.

  3. Use of Quality Models and Indicators for Evaluating Test Quality in an ESP Course

    Directory of Open Access Journals (Sweden)

    IEVA RUDZINSKA

    2013-12-01

    Full Text Available Qualitative methods of assessment play a decisive role in education in general and in language learning in particular. The necessity to perform a qualitative assessment comes from both increased student competition in higher education institutions (HEIs, and hence higher demands for fair assessment, and a growing public awareness on higher education issues, and therefore the need to account for a wider circle of stakeholders, including society as a whole. The aim of the present paper is to study the regulations and laws pertaining to the issue of assessment in Latvian HEIs, as well as to carry out literature sources analysis about assessment in language testing, seeking to select criteria characterizing the quality of English for Specific Purposes (ESP tests and to apply the model of evaluating the quality of a language test on an example of a test in sport English, developed in a Latvian higher education institution. An analysis of the regulations and laws about assessment in higher education and literature sources about tests in language courses has enabled the development of a test quality model, consisting of seven intrinsic quality criteria: clarity, adequacy, deep approach, attractiveness, originality/similarity, orientation towards student learning result/process, test scoring objectivity/subjectivity. Quality criteria comprise eleven indicators. The reliability of the given model is evaluated by means of the whole model, its criteria and indicator Cronbach’s alphas and point-biserial (item-total correlations or discrimination indexes DI. The test was taken by 63 participants, all of them 2nd year full time students attending a Latvian higher education institution. A statistical data analysis was performed with SPSS 17.0. The results show that, although test adequacy and clarity is sufficiently high, attractiveness and deep approach should be improved. Also the reliability of one version of the test is higher than that of the other one

  4. Higher Quality of Molecular Testing, an Unfulfilled Priority: Results from External Quality Assessment for KRAS Mutation Testing in Colorectal Cancer

    NARCIS (Netherlands)

    Tembuyser, L.; Ligtenberg, M.J.L.; Normanno, N.; Delen, S.; Krieken, J.H.J.M. van; Dequeker, E.M.

    2014-01-01

    Precision medicine is now a key element in clinical oncology. RAS mutational status is a crucial predictor of responsiveness to anti-epidermal growth factor receptor agents in metastatic colorectal cancer. In an effort to guarantee high-quality testing services in molecular pathology, the European

  5. Handling Qualities Flight Testing of the Stratospheric Observatory for Infrared Astronomy (SOFIA)

    Science.gov (United States)

    Glaser, Scott T.; Strovers, Brian K.

    2011-01-01

    Airborne infrared astronomy has a long successful history, albeit relatively unknown outside of the astronomy community. A major problem with ground based infrared astronomy is the absorption and scatter of infrared energy by water in the atmosphere. Observing the universe from above 40,000 ft puts the observation platform above 99% of the water vapor in the atmosphere, thereby addressing this problem at a fraction of the cost of space based systems. The Stratospheric Observatory For Infrared Astronomy (SOFIA) aircraft is the most ambitious foray into the field of airborne infrared astronomy in history. Using a 747SP (The Boeing Company, Chicago, Illinois) aircraft modified with a 2.5m telescope located in the aft section of the fuselage, the SOFIA endeavors to provide views of the universe never before possible and at a fraction of the cost of space based systems. The modification to the airplane includes moveable doors and aperture that expose the telescope assembly. The telescope assembly is aimed and stabilized using a multitude of on board systems. This modification has the potential to cause aerodynamic anomalies that could induce undesired forces either at the cavity itself or indirectly due to interference with the empennage, both of which could cause handling qualities issues. As a result, an extensive analysis and flight test program was conducted from December 2009 through March 2011. Several methods, including a Lower Order Equivalent Systems analysis and pilot assessment, were used to ascertain the effects of the modification. The SOFIA modification was found to cause no adverse handling qualities effects and the aircraft was cleared for operational use. This paper discusses the history and modification to the aircraft, development of test procedures and analysis, results of testing and analysis, lessons learned for future projects and justification for operational certification.

  6. Region III involvement in quality control and quality assurance of radon testing methods

    International Nuclear Information System (INIS)

    Coyle, F.T.

    1990-01-01

    Region III has set a goal of increasing the testing for radon by our residents. One approach to this goal, is to bolster the public's confidence in the testing laboratories. We believe that this can be done most effectively by assuring the quality of the measurements available to the public. All Proficient Laboratories and Pennsylvania Certified Laboratories have submitted a quality assurance (QA) program. A QA audit checklist has been developed which will be finalized and made available to the states in our Region. This paper deals with inspection, verification, and documentation of the various laboratories and their compliance with prudent measuring protocols and addresses the following items: Organization and responsibilities; Sampling procedures; Detector chain of custody; Measurement procedures, quality control checks; State certification and RMP; Data resection, validation, and reporting; Quality assurance reports to management; Interview and discussion of QA audit with responsible officer

  7. Rail-Cask Tests: Normal-Conditionsof- Transport Tests of Surrogate PWR Fuel Assemblies in an ENSA ENUN 32P Cask.

    Energy Technology Data Exchange (ETDEWEB)

    McConnell, Paul E. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Ross, Steven [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Grey, Carissa Ann [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Uncapher, William Leonard [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Arviso, Michael [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Garmendia, Rafael [Equipos Nucleares Sociedad Anonima, Madrid (Spain); Fernandez Perez, Ismael [Equipos Nucleares Sociedad Anonima, Madrid (Spain); Palacio, Alejandro [Equipos Nucleares Sociedad Anonima, Madrid (Spain); Calleja, Guillermo [Equipos Nucleares Sociedad Anonima, Madrid (Spain); Garrido, David [COORDINADORA, Madrid (Spain); Rodriguez Casas, Ana [COORDINADORA, Madrid (Spain); Gonzalez Garcia, Luis [COORDINADORA, Madrid (Spain); Chilton, Lyman Wes [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Ammerman, Douglas J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Walz, Jacob [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Gershon, Sabina [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Saltzstein, Sylvia J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Sorenson, Ken [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Klymyshyn, Nicholas [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Hanson, Brady [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Pena, Ruben [Transportation Technology Center, Inc., Pueblo, CO (United States); Walker, Russell [Transportation Technology Center, Inc., Pueblo, CO (United States)

    2018-01-01

    This report describes tests conducted using a full-size rail cask, the ENSA ENUN 32P, involving handling of the cask and transport of the cask via truck, ships, and rail. The purpose of the tests was to measure strains and accelerations on surrogate pressurized water reactor fuel rods when the fuel assemblies were subjected to Normal Conditions of Transport within the rail cask. In addition, accelerations were measured on the transport platform, the cask cradle, the cask, and the basket within the cask holding the assemblies. These tests were an international collaboration that included Equipos Nucleares S.A., Sandia National Laboratories, Pacific Northwest National Laboratory, Coordinadora Internacional de Cargas S.A., the Transportation Technology Center, Inc., the Korea Radioactive Waste Agency, and the Korea Atomic Energy Research Institute. All test results in this report are PRELIMINARY – complete analyses of test data will be completed and reported in FY18. However, preliminarily: The strains were exceedingly low on the surrogate fuel rods during the rail-cask tests for all the transport and handling modes. The test results provide a compelling technical basis for the safe transport of spent fuel.

  8. Tandem Mirror Experiment-Upgrade neutral beam test stand: A powerful tool for development and quality assurance

    International Nuclear Information System (INIS)

    Hibbs, S.M.; Kane, R.J.; Kerr, R.G.; Poulsen, P.

    1983-01-01

    During construction of the Tandem Mirror Experiment-Upgrade (TMX-U), a test stand was assembled to develop electronics for the neutral beam system. In the first six months of test stand use the authors operated a few neutral beam injector modules and directed considerable effort toward improving the electronic system. As system development progressed, the focus turned toward improving the injector modules themselves. The test stand has proved to be the largest single contributor to the successful operation of neutral beams on TMX-U, primarily because it provides quality assurance and development capability in conjunction with the scheduled activities of the main experiment. This support falls into five major categories: (1) electronics development, (2) operator training, (3) injector module testing and characterization, (4) injector module improvements, and (5) physics improvements (through areas affected by injector operation). Normal day-to-day operation of the test stand comes under the third category, testing and characterization, and comprises the final quality assurance activity for newly assembled or repaired modules before they are installed on TMX-U. They have also used the test stand to perform a series of physics experiments, including: reducing gas flow through valve and arc chamber characterization, reducing impurities by titanium gettering, and reducing streaming gas using apertures and collisional gas dynamics

  9. Artificial enzyme-powered microfish for water-quality testing.

    Science.gov (United States)

    Orozco, Jahir; García-Gradilla, Victor; D'Agostino, Mattia; Gao, Wei; Cortés, Allan; Wang, Joseph

    2013-01-22

    We present a novel micromotor-based strategy for water-quality testing based on changes in the propulsion behavior of artificial biocatalytic microswimmers in the presence of aquatic pollutants. The new micromotor toxicity testing concept mimics live-fish water testing and relies on the toxin-induced inhibition of the enzyme catalase, responsible for the biocatalytic bubble propulsion of tubular microengines. The locomotion and survival of the artificial microfish are thus impaired by exposure to a broad range of contaminants, that lead to distinct time-dependent irreversible losses in the catalase activity, and hence of the propulsion behavior. Such use of enzyme-powered biocompatible polymeric (PEDOT)/Au-catalase tubular microengine offers highly sensitive direct optical visualization of changes in the swimming behavior in the presence of common contaminants and hence to a direct real-time assessment of the water quality. Quantitative data on the adverse effects of the various toxins upon the swimming behavior of the enzyme-powered artificial swimmer are obtained by estimating common ecotoxicological parameters, including the EC(50) (exposure concentration causing 50% attenuation of the microfish locomotion) and the swimmer survival time (lifetime expectancy). Such novel use of artificial microfish addresses major standardization and reproducibility problems as well as ethical concerns associated with live-fish toxicity assays and hence offers an attractive alternative to the common use of aquatic organisms for water-quality testing.

  10. Development of a quality management system for borehole investigations. (1) Quality assurance and quality control methodology for hydraulic packer testing

    International Nuclear Information System (INIS)

    Takeuchi, Shinji; Kunimaru, Takanori; Ota, Kunio; Frieg, Bernd

    2011-01-01

    A quality assurance and quality control (QA/QC) system for the hydraulic packer tests has been established based on the surface-based investigations at JAEA's underground research laboratories in Mizunami and Horonobe. The established QA/QC system covers field investigations (data acquisition) and data analysis. For the field investigations, the adopted procedure is selection of a test section based on a detail fluid logging and checking with tally list, followed by inspection of test tools such as pressure transducers and shut-in valves, etc., test method selection using a 'sequential hydraulic test' for deciding appropriate method, and finally data quality confirmation by pressure changes and derivatives on a log-log plots during testing. Test event logs should also be described during testing for traceability. For the test data analysis, a quick analysis for rough estimation of hydraulic parameters, and a detailed analysis using type curve and/or numerical analyses are conducted stepwise. The established QA/QC system has been applied to the recent borehole investigations and its efficiency has been confirmed. (author)

  11. Connections between transcription, mRNP assembly and quality control in S. cerevisiae

    DEFF Research Database (Denmark)

    Jensen, Torben Heick

    in the context of THO and rna14-3 mutants improves mRNP quality by acting upstream of transcription-site retention and nuclear degradation of the transcripts. As Rad3p mutant effects can be phenocopied by other mutations known to affect transcription and by the addition of transcription elongation drugs, our...

  12. Quality assurance during site construction. Pt. 4

    International Nuclear Information System (INIS)

    Potrz, R.; Dilling, H.

    1980-01-01

    Quality control during the assembly of an pressure water reactor containment: 1.) Fundamental principles of the quality control: short explanation to the specification and job instruction. 2.) Quality control during the assembly: welding control, non destructive material test. 3.) Quality deviations: explanation of an repair-plan. 4.) Documentation: join together the workshop- and site documentation. (orig.)

  13. Quality of prenatal care questionnaire: instrument development and testing

    Science.gov (United States)

    2014-01-01

    Background Utilization indices exist to measure quantity of prenatal care, but currently there is no published instrument to assess quality of prenatal care. The purpose of this study was to develop and test a new instrument, the Quality of Prenatal Care Questionnaire (QPCQ). Methods Data for this instrument development study were collected in five Canadian cities. Items for the QPCQ were generated through interviews with 40 pregnant women and 40 health care providers and a review of prenatal care guidelines, followed by assessment of content validity and rating of importance of items. The preliminary 100-item QPCQ was administered to 422 postpartum women to conduct item reduction using exploratory factor analysis. The final 46-item version of the QPCQ was then administered to another 422 postpartum women to establish its construct validity, and internal consistency and test-retest reliability. Results Exploratory factor analysis reduced the QPCQ to 46 items, factored into 6 subscales, which subsequently were validated by confirmatory factor analysis. Construct validity was also demonstrated using a hypothesis testing approach; there was a significant positive association between women’s ratings of the quality of prenatal care and their satisfaction with care (r = 0.81). Convergent validity was demonstrated by a significant positive correlation (r = 0.63) between the “Support and Respect” subscale of the QPCQ and the “Respectfulness/Emotional Support” subscale of the Prenatal Interpersonal Processes of Care instrument. The overall QPCQ had acceptable internal consistency reliability (Cronbach’s alpha = 0.96), as did each of the subscales. The test-retest reliability result (Intra-class correlation coefficient = 0.88) indicated stability of the instrument on repeat administration approximately one week later. Temporal stability testing confirmed that women’s ratings of their quality of prenatal care did not change as a result of giving

  14. Quality of prenatal care questionnaire: instrument development and testing.

    Science.gov (United States)

    Heaman, Maureen I; Sword, Wendy A; Akhtar-Danesh, Noori; Bradford, Amanda; Tough, Suzanne; Janssen, Patricia A; Young, David C; Kingston, Dawn A; Hutton, Eileen K; Helewa, Michael E

    2014-06-03

    Utilization indices exist to measure quantity of prenatal care, but currently there is no published instrument to assess quality of prenatal care. The purpose of this study was to develop and test a new instrument, the Quality of Prenatal Care Questionnaire (QPCQ). Data for this instrument development study were collected in five Canadian cities. Items for the QPCQ were generated through interviews with 40 pregnant women and 40 health care providers and a review of prenatal care guidelines, followed by assessment of content validity and rating of importance of items. The preliminary 100-item QPCQ was administered to 422 postpartum women to conduct item reduction using exploratory factor analysis. The final 46-item version of the QPCQ was then administered to another 422 postpartum women to establish its construct validity, and internal consistency and test-retest reliability. Exploratory factor analysis reduced the QPCQ to 46 items, factored into 6 subscales, which subsequently were validated by confirmatory factor analysis. Construct validity was also demonstrated using a hypothesis testing approach; there was a significant positive association between women's ratings of the quality of prenatal care and their satisfaction with care (r = 0.81). Convergent validity was demonstrated by a significant positive correlation (r = 0.63) between the "Support and Respect" subscale of the QPCQ and the "Respectfulness/Emotional Support" subscale of the Prenatal Interpersonal Processes of Care instrument. The overall QPCQ had acceptable internal consistency reliability (Cronbach's alpha = 0.96), as did each of the subscales. The test-retest reliability result (Intra-class correlation coefficient = 0.88) indicated stability of the instrument on repeat administration approximately one week later. Temporal stability testing confirmed that women's ratings of their quality of prenatal care did not change as a result of giving birth or between the early postpartum

  15. The Quality Testing of Water from Microbiology and Radioactivity

    International Nuclear Information System (INIS)

    Zainul Kamal; Yazid, M.; Mulyaningsih; Iim lmroatin

    2002-01-01

    The quality testing of well water from microbiologic and radioactivity has been done. The samples were taken from Degolan and Lodadi village, Ngemplak, Sleman. The quality testing based from standard procedure of microbiologic and environmental radioactivity. From the experimentally results showed that E. Coli in well water = 5 - 920 JPT / 100 ml, Streptococcus in well water 0 - 4 JPT /100 ml, E. Coli and Streptococcus in PAM water 0 JPT / 100 ml, radioactivity β totally in well water 0.08-0.34 Bq/l and in PAM water 0.08 - 0.31 Bq/l. From the dates required could be concluded that in microbiologically aspects the value of E. Coli and Streptococcus in well water higher than the threshold value from Health Department Rl 416/Menkes/PER/IX/1990, in radioactivity aspect lower than the threshold value from Health Department RI 416/Menkes/PER/IX/1990. (author)

  16. Assembly and Test of HD2, a 36 mm bore high field Nb3Sn Dipole Magnet

    International Nuclear Information System (INIS)

    Ferracin, P.; Bingham, B.; Caspi, S.; Cheng, D.W.; Dietderich, D.R.; Felice, H.; Godeke, A.; Hafalia, A.R.; Hannaford, C.R.; Joseph, J.; Lietzke, A.F.; Lizarazo, J.; Sabbi, G.; Trillaud, F.; Wang, X.

    2008-01-01

    We report on the fabrication, assembly, and test of the Nb 3 Sn dipole magnet HD2. The magnet, aimed at demonstrating the application of Nb 3 Sn superconductor in high field accelerator-type dipoles, features a 36 mm clear bore surrounded by block-type coils with tilted ends. The coil design is optimized to minimize geometric harmonics in the aperture and the magnetic peak field on the conductor in the coil ends. The target bore field of 15 T at 4.3 K is consistent with critical current measurements of extracted strands. The coils are horizontally pre-stressed during assembly using an external aluminum shell pre-tensioned with water-pressurized bladders. Axial pre-loading of the coil ends is accomplished through two end plates and four aluminum tension rods. The strain in coil, shell, and rods is monitored with strain gauges during assembly, cool-down and magnet excitation, and compared with 3D finite element computations. Magnet's training performance, quench locations, and ramp-rate dependence are then analyzed and discussed.

  17. Tandem mirror experiment-upgrade neutral beam test stand: a powerful tool for development and quality assurance

    International Nuclear Information System (INIS)

    Hibbs, S.M.; Kane, R.J.; Kerr, R.G.; Poulsen, P.

    1983-01-01

    During construction of the Tandem Mirror Experiment-Upgrade (TMX-U), we assembled a test stand to develop electronics for the neutral beam system. In the first six months of test stand use we operated a few neutral beam injector modules and directed considerable effort toward improving the electronic system. As system development progressed, our focus turned toward improving the injector modules themselves. The test stand has proved to be the largest single contributor to the successful operation of neutral beams on TMX-U, primarily because it provides quality assurance andd development capability in conjunction with the scheduled activities of the main experiment. This support falls into five major categories: (1) electronics development, (2) operator training, (3) injector module testing and characterization, (4) injector module improvements, and (5) physics improvements (through areas affected by injector operation). Normal day-to-day operation of the test stand comes under the third category, testing and characterization, and comprises our final quality assurance activity for newly assembled or repaired modules before they are installed on TMX-U

  18. Analysis of factors affecting the LOCA test quality

    International Nuclear Information System (INIS)

    Wang Lu

    2008-01-01

    Localization of nuclear safety-related equipment has become an important way of nuclear power development in China. To meet this demand, the competence should be promoted in the following two areas, one is to develop the capability of R and D and manufacturing of nuclear safety-related equipment, the other is to implement equipment qualification according to relevant codes and standards. As LOCA test is one of the most important parts in the qualification test of nuclear safety-related equipment, the main factors related with the quality of the LOCA test are analyzed in this paper, and this may be a reference to improve the skills in designing, constructing and operating LOCA test devices. (authors)

  19. Quality assurance of radiopharmaceuticals - specifications and test procedures

    International Nuclear Information System (INIS)

    Baldas, J.; Bonnyman, J.; Colmanet, S.F.; Ivanov, Z.; Lauder, R.A.

    1990-10-01

    The authors report on a Radiopharmaceutical Quality Assurance Test Programme carried out by the Australian Radiation Laboratory in which radiopharmaceuticals used in nuclear medicine in Australia are tested for compliance with specifications. Where the radiopharmaceutical is the subject of a monograph in the British Pharmacopoeia or the European Pharmacopoeia, then the specifications given in the Pharmacopoeia are adopted. In other cases the specifications given have been adopted by this Laboratory and have no legal status. In some cases test procedures described have been taken from various Pharmacopoeias or methods published in the literature. In other cases test methods described have been developed at this Laboratory. It should be noted that, unless stated otherwise, specifications listed apply at all times up until product expire

  20. [Study on seed quality test and quality standard of Pesudostellaria heterophylla].

    Science.gov (United States)

    Xiao, Cheng-Hong; Zhou, Tao; Jiang, Wei-Ke; Chen, Min; Xiong, Hou-Xi; Liao, Ming-Wu

    2014-08-01

    Referring to the rules for agricultural seed testing (GB /T 3543-1995) issued by China, the test of sampling, seed purity, weight per 1 000 seeds, seed moisture, seed viability and germination rate had been studied for screening seed quality test methods of Pesudostellaria heterophylla. The seed quality from different collection areas was measured. The results showed that at least 6.5 g seeds should be sampled and passed through 10-mesh sieve for purity analysis. The weight of 1 000 seeds was determined by using the 500-seed method. The phenotypic observation and size measurement were used for authenticity testing. The seed moisture was determined under the higher temperature (130 ± 2) degrees C for 5 hours. The seeds were dipped into 0.2% TTC sustaining 1 hour at 40 degrees C, then the viability could be determined. The break dormancy seeds were cultured on sand at 10 degrees C. K cluster analysis was applied for the data analysis, the seed quality from different collection areas grading of P. Heterophylla was described as three grades. The seed quality of each grade should reach following requirements: for first grade seeds, germination rate ≥ 86%, 1 000-grain weight ≥ 2.59 g, purity ≥ 87%, moisture ≤ 13.1%; for second grade seeds, germination rate ≥ 70%, 1 000-grain weight ≥ 2.40 g, purity ≥ 77%, moisture ≤ 14.3%; for third grade seeds, germination rate ≥ 41%, 1 000-grain weight ≥ 2.29 g, purity ≥ 76%, moisture ≤ 15.8%. The seed testing methods for quality items of P. heterophylla had been initially established, as well as the primary P. heterophylla seed quality classification standard.

  1. [Study on seed quality test and quality standard of Lonicera macranthoides].

    Science.gov (United States)

    Zhang, Ying; Xu, Jin; Li, Long-Yun; Cui, Guang-Lin; She, Yue-Hui

    2016-04-01

    Referring to the rules for agricultural seed testing (GB/T 3543-1995) issued by China, the test of sampling, purity, thousand seed weight, moisture, viability, relative conductivity and germination rate had been studied for seed quality test methods of Lonicera macranthoides. The seed quality from 38 different collection areas was measured to establish quality classification standard by K-means clustering. The results showed that at least 7.5 g seeds should be sampled, and passed 20-mesh sieve for purity analysis.The 500-seed method used to measure thousand seed weight. The moisture was determined by crushed seeds dried in high temperature (130±2) ℃ for 3 h.The viability determined by 25 ℃ 0.1% TTC stained 5h in dark. 1.0 g seeds soaked in 50 ml ultra pure water in 25 ℃ for 12 hours to determine the relative conductivity. The seed by 4 ℃stratification for 80 days were cultured on paper at 15 ℃. Quality of the seeds from different areas was divided into three grades. The primary seed quality classification standard was established.The I grade and II grade were recommend use in production. Copyright© by the Chinese Pharmaceutical Association.

  2. Experimental Investigation Of Microbially Induced Corrosion Of Test Samples And Effect Of Self-assembled Hydrophobic Monolayers. Exposure Of Test Samples To Continuous Microbial Cultures, Chemical Analysis, And Biochemical Studies

    CERN Document Server

    Laurinavichius, K S

    1998-01-01

    Experimental Investigation Of Microbially Induced Corrosion Of Test Samples And Effect Of Self-assembled Hydrophobic Monolayers. Exposure Of Test Samples To Continuous Microbial Cultures, Chemical Analysis, And Biochemical Studies

  3. Quality Assurance Protocol for AFCI Advanced Structural Materials Testing

    Energy Technology Data Exchange (ETDEWEB)

    Busby, Jeremy T [ORNL

    2009-05-01

    The objective of this letter is to inform you of recent progress on the development of advanced structural materials in support of advanced fast reactors and AFCI. As you know, the alloy development effort has been initiated in recent months with the procurement of adequate quantities of the NF616 and HT-UPS alloys. As the test alloys become available in the coming days, mechanical testing, evaluation of optimizing treatments, and screening of environmental effects will be possible at a larger scale. It is therefore important to establish proper quality assurance protocols for this testing effort in a timely manner to ensure high technical quality throughout testing. A properly implemented quality assurance effort will also enable preliminary data taken in this effort to be qualified as NQA-1 during any subsequent licensing discussions for an advanced design or actual prototype. The objective of this report is to describe the quality assurance protocols that will be used for this effort. An essential first step in evaluating quality protocols is assessing the end use of the data. Currently, the advanced structural materials effort is part of a long-range, basic research and development effort and not, as yet, involved in licensing discussions for a specific reactor design. After consultation with Mark Vance (an ORNL QA expert) and based on the recently-issued AFCI QA requirements, the application of NQA-1 quality requirements will follow the guidance provided in Part IV, Subpart 4.2 of the NQA-1 standard (Guidance on Graded Application of QA for Nuclear-Related Research and Development). This guidance mandates the application of sound scientific methodology and a robust peer review process in all phases, allowing for the data to be qualified for use even if the programmatic mission changes to include licensing discussions of a specific design or prototype. ORNL has previously implemented a QA program dedicated to GNEP activities and based on an appropriately graded

  4. Quality Assurance Protocol for AFCI Advanced Structural Materials Testing

    International Nuclear Information System (INIS)

    Busby, Jeremy T.

    2009-01-01

    The objective of this letter is to inform you of recent progress on the development of advanced structural materials in support of advanced fast reactors and AFCI. As you know, the alloy development effort has been initiated in recent months with the procurement of adequate quantities of the NF616 and HT-UPS alloys. As the test alloys become available in the coming days, mechanical testing, evaluation of optimizing treatments, and screening of environmental effects will be possible at a larger scale. It is therefore important to establish proper quality assurance protocols for this testing effort in a timely manner to ensure high technical quality throughout testing. A properly implemented quality assurance effort will also enable preliminary data taken in this effort to be qualified as NQA-1 during any subsequent licensing discussions for an advanced design or actual prototype. The objective of this report is to describe the quality assurance protocols that will be used for this effort. An essential first step in evaluating quality protocols is assessing the end use of the data. Currently, the advanced structural materials effort is part of a long-range, basic research and development effort and not, as yet, involved in licensing discussions for a specific reactor design. After consultation with Mark Vance (an ORNL QA expert) and based on the recently-issued AFCI QA requirements, the application of NQA-1 quality requirements will follow the guidance provided in Part IV, Subpart 4.2 of the NQA-1 standard (Guidance on Graded Application of QA for Nuclear-Related Research and Development). This guidance mandates the application of sound scientific methodology and a robust peer review process in all phases, allowing for the data to be qualified for use even if the programmatic mission changes to include licensing discussions of a specific design or prototype. ORNL has previously implemented a QA program dedicated to GNEP activities and based on an appropriately graded

  5. The influence of biomass quality on the purification of flue gases and multicyclone assembly material

    Directory of Open Access Journals (Sweden)

    A. Čikić

    2013-01-01

    Full Text Available Various types, forms and states affect the heating value of biomass and its conversion into exploitable energy forms. As a result of biomass quality investigations, the share of solid particles in flue gases purified in a multicyclone was measured and analyzed at various heating loads of a boiler, the maximum power of which amounts to 2,2 MW. This paper presents the influence of flue gases on the roughness and corrosiveness of multicyclone material inner wall. A corrective dimensional parameter of the multicyclone was suggested for the purpose of maximum purification of flue gases at unfavorable incineration conditions and biomass characteristics.

  6. Quality standards for sample collection in coagulation testing.

    Science.gov (United States)

    Lippi, Giuseppe; Salvagno, Gian Luca; Montagnana, Martina; Lima-Oliveira, Gabriel; Guidi, Gian Cesare; Favaloro, Emmanuel J

    2012-09-01

    Preanalytical activities, especially those directly connected with blood sample collection and handling, are the most vulnerable steps throughout the testing process. The receipt of unsuitable samples is commonplace in laboratory practice and represents a serious problem, given the reliability of test results can be adversely compromised following analysis of these specimens. The basic criteria for an appropriate and safe venipuncture are nearly identical to those used for collecting blood for clinical chemistry and immunochemistry testing, and entail proper patient identification, use of the correct technique, as well as appropriate devices and needles. There are, however, some peculiar aspects, which are deemed to be particularly critical when collecting quality specimens for clot-based tests, and these require clearer recognition. These include prevention of prolonged venous stasis, collection of nonhemolyzed specimens, order of draw, and appropriate filling and mixing of the primary collection tubes. All of these important preanalytical issues are discussed in this article, and evidence-based suggestions as well as recommendations on how to obtain a high-quality sample for coagulation testing are also illustrated. We have also performed an investigation aimed to identify variation of test results due to underfilling of primary blood tubes, and have identified a clinically significant bias in test results when tubes are drawn at less than 89% of total fill for activated partial thromboplastin time, less than 78% for fibrinogen, and less than 67% for coagulation factor VIII, whereas prothrombin time and activated protein C resistance remain relatively reliable even in tubes drawn at 67% of the nominal volume. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  7. NHR dynamic analysis of control rod and fuel assembly of test model

    International Nuclear Information System (INIS)

    Wang Jiachun; Cai Laizhong

    2001-01-01

    The basic purpose is to analyze the dynamic response of the structure, with the seismic excitation, which is the important components of 200 MW Heating Reactor, including the control rod, fuel assembly, zirconium alloy boxes and the relevant parts. The author presents the simplification and building of the model. By comparing the effects under different constraint conditions, the final analyzed model is determined after the preliminary analysis. Then the model is calculated to obtain the frequencies of the model, the analysis of the response spectrum and the time series data under some seismic excitations. From the outcome what is received above, the influence of the basic frequency is discussed. And the displacement and acceleration responses of different sample points are obtained and analyzed to predict the safety of the reactor

  8. Performance of multihundred-watt fueled-sphere assemblies in the safety sequential test program

    International Nuclear Information System (INIS)

    Cramer, E.M.

    1975-07-01

    Five fueled-sphere assemblies similar to those proposed for use in the multihundred-watt radioisotope thermoelectric generator were subjected to conditions simulating earth impact after orbital abort. Of the five, one had no visible cracks, two had superficial cracks whose penetration of the iridium containment shell was not verified by metallography, one was obviously ruptured, and the fuel of one was exposed. The basic causes of containment failure were as follows: large-grained iridium provided short, straight boundary paths susceptible to intergranular fracturing; large plutonia fragments produced excessive tensile strain in the containment where it was forced to bend over their projecting edges at the moment of impact; vents failed because of sintering and CVD of nonmetallic materials in the filter frits; and, of less significance, directional grain growth in closure welds apparently caused one failure. (U.S.)

  9. Results of the quality assurance testing program for radiopharmaceuticals 1995

    International Nuclear Information System (INIS)

    Baldas, J.; Binnyman, J.; Ivanov, Z.; Lauder, R.

    1996-07-01

    The results of the quality assurance testing conducted by the Australian Radiation Laboratory is summarised. Overall 111 batches of 27 different types of radiopharmaceuticals were tested on samples obtained through normal commercial channels. Failure to meet full specifications was observed in 10 of the 111 batches. All technetium-99m cold kits were reconstituted according to the directions in the package insert using sodium pertechnetate ( 99m Tc) injection. Radionuclidic purity has been determined at the calibration time, except for Thallous [ 201 Tl] Chloride injection where the highest impurity level up to product expiry is quoted. Non-compliance of the vial label was observed in one of the ten batches failing specification and was the sole cause of product failure for this batch. Vial label non-compliance consisted of, absence of volume in the vial. Six batches failed the biodistribution test but in no case did this involve failure of the distribution for the target organs. tabs

  10. Results of the quality assurance testing program for radiopharmaceuticals 1995

    Energy Technology Data Exchange (ETDEWEB)

    Baldas, J.; Binnyman, J.; Ivanov, Z.; Lauder, R.

    1996-07-01

    The results of the quality assurance testing conducted by the Australian Radiation Laboratory is summarised. Overall 111 batches of 27 different types of radiopharmaceuticals were tested on samples obtained through normal commercial channels. Failure to meet full specifications was observed in 10 of the 111 batches. All technetium-99m cold kits were reconstituted according to the directions in the package insert using sodium pertechnetate ( {sup 99m}Tc) injection. Radionuclidic purity has been determined at the calibration time, except for Thallous [{sup 201}Tl] Chloride injection where the highest impurity level up to product expiry is quoted. Non-compliance of the vial label was observed in one of the ten batches failing specification and was the sole cause of product failure for this batch. Vial label non-compliance consisted of, absence of volume in the vial. Six batches failed the biodistribution test but in no case did this involve failure of the distribution for the target organs. tabs.

  11. Data Quality Objectives For Selecting Waste Samples To Test The Fluid Bed Steam Reformer Test

    International Nuclear Information System (INIS)

    Banning, D.L.

    2010-01-01

    This document describes the data quality objectives to select archived samples located at the 222-S Laboratory for Fluid Bed Steam Reformer testing. The type, quantity and quality of the data required to select the samples for Fluid Bed Steam Reformer testing are discussed. In order to maximize the efficiency and minimize the time to treat Hanford tank waste in the Waste Treatment and Immobilization Plant, additional treatment processes may be required. One of the potential treatment processes is the fluid bed steam reformer (FBSR). A determination of the adequacy of the FBSR process to treat Hanford tank waste is required. The initial step in determining the adequacy of the FBSR process is to select archived waste samples from the 222-S Laboratory that will be used to test the FBSR process. Analyses of the selected samples will be required to confirm the samples meet the testing criteria.

  12. Fireworks Assembler (Fireworks) 737.887 -- Technical Report on Standardization of the General Aptitude Test Battery.

    Science.gov (United States)

    Manpower Administration (DOL), Washington, DC. U.S. Training and Employment Service.

    The United States Training and Employment Service General Aptitude Test Battery (GATB), first published in 1947, has been included in a continuing program of research to validate the tests against success in many different occupations. The GATB consists of 12 tests which measure nine aptitudes: General Learning Ability; Verbal Aptitude; Numerical…

  13. DOE JGI Quality Metrics; Approaches to Scaling and Improving Metagenome Assembly (Metagenomics Informatics Challenges Workshop: 10K Genomes at a Time)

    Energy Technology Data Exchange (ETDEWEB)

    Copeland, Alex; Brown, C. Titus

    2011-10-13

    DOE JGI's Alex Copeland on "DOE JGI Quality Metrics" and Michigan State University's C. Titus Brown on "Approaches to Scaling and Improving Metagenome Assembly" at the Metagenomics Informatics Challenges Workshop held at the DOE JGI on October 12-13, 2011.

  14. Necessity for quality assurance tests of tritium gas

    International Nuclear Information System (INIS)

    Bender, L.; Bhat, R.; Guadagno, J.; Sotomayor, R.; Funkhouser, M.; Plasket, E.

    1989-01-01

    For the past 20 years, the U.S. Army has used self-illuminating tritium excited phosphor vials inside the Lensatic compass for night illumination. Tritium was selected as the illuminating mechanism based on calculations from its half-life that projected its field life to be 12 years. Studies conducted by the Radiation Research Group detected deficiencies between the actual luminosity life of the compass and the projected life. Based on this observation, the group conducted subsequent studies to determine if the discrepancy could be attributed to the phosphor or the composition of the tritium contained in the vial. These studies revealed that the composition of tritium gas used in the compass did not match the specifications set for the gas. The group has since incorporated rigorous quality controls in the specifications to avoid future discrepancies. This work has pointed out the need for all tritium vial users to establish specifications and quality control tests for tritium vials

  15. Physical quality control and nondestructive testing in industry

    International Nuclear Information System (INIS)

    Akay, K. S.; Avinc, A.

    2000-01-01

    The applications of Total Quality Management which now constitute the main factor of production and industrial life, are becoming widespread each day. This study evaluates the place, and the role of the physicist in the development and the application of measuring and central method, providing information on quality, environment and especially reliability, which is me of the most significant components of these concepts, acting as a guide and known, as Nondestructive Testing Methods in technology. Basic physical principles of the techniques, employed in practical applications as well as research and development stages of different fields requiring advanced technology, are presented and their advantages and disadvantages in usage are demonstrated in a comparative way. (authors)

  16. Standard Practice for Quality Management Systems for Nondestructive Testing Agencies

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This practice covers general requirements for the establishment and maintenance of a quality management system for agencies engaged in nondestructive testing (NDT). 1.2 This practice utilizes criteria contained in Practice E 543. 1.3 This practice utilizes criteria contained in American National Standard ANSI/ISO/ASQ Q9001–2000, Quality management systems—Requirements. 1.4 This practice recognizes the importance of establishing minimum safety criteria. 1.5 The use of SI or inch-pound units, or combinations thereof, will be the responsibility of the technical committee whose standards are referred to in this standard. 1.6 This practice does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this practice to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  17. Quality Assurance and Quality Control in Point-of-Care Testing.

    Science.gov (United States)

    Newman, Ashleigh W; Behling-Kelly, Erica

    2016-03-01

    With advancements in the standard of care in veterinary medicine and instrument technology, performing in-house laboratory work on a variety of point-of-care instruments, ranging from glucometers to benchtop chemistry analyzers, has become increasingly commonplace. However, the ability of an instrument to perform a test does not guarantee that those results are accurate. Ensuring that your in-clinic laboratory is providing reliable data requires a comprehensive plan that encompasses both common sense practices aimed at preventing errors at each stage of the testing process, as well as standard operating procedures to validate and monitor analyzer performance. These 2 arms of the plan are known as quality assurance and quality control. Although these concepts are typically out of the comfort zone for veterinarians, just as the thought of business management may deter some veterinarians from practice ownership, it is not beyond the capabilities of veterinarians to learn, understand, and incorporate them into their practice. The objectives of this article are to convey the importance of quality assurance and quality control, walk you through the American Society for Veterinary Clinical Pathology guidelines on this topic, and provide direction to additional resources for further education on this topic, all with the focus on point-of-care testing in the in-clinic laboratory. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. Effect of Time and Deposition Method on Quality of Phosphonic Acid Modifier Self-Assembled Monolayers on Indium Zinc Oxide

    Energy Technology Data Exchange (ETDEWEB)

    Sang, Lingzi; Knesting, Kristina M.; Bulusu, Anuradha; Sigdel, Ajaya K.; Giordano, Anthony J.; Marder, Seth R.; Berry, Joseph J.; Graham, Samuel; Ginger, David S.; Pemberton, Jeanne E.

    2016-12-15

    Phosphonic acid (PA) self-assembled monolayers (SAMs) are utilized at critical interfaces between transparent conductive oxides (TCO) and organic active layers in organic photovoltaic devices (OPVs). The effects of PA deposition method and time on the formation of close-packed, high-quality monolayers is investigated here for SAMs fabricated by solution deposition, micro-contact printing, and spray coating. The solution deposition isotherm for pentafluorinated benzylphosphonic acid (F5BnPA) on indium-doped zinc oxide (IZO) is studied using polarization modulation-infrared reflection-absorption spectroscopy (PM-IRRAS) at room temperature as a model PA/IZO system. Fast surface adsorption occurs within the first min; however, well-oriented high-quality SAMs are reached only after -48 h, presumably through a continual process of molecular adsorption/desorption and monolayer filling accompanied by molecular reorientation. Two other rapid, soak-free deposition techniques, micro-contact printing and spray coating, are also explored. SAM quality is compared for deposition of phenyl phosphonic acid (PPA), F13-octylphosphonic acid (F13OPA), and pentafluorinated benzyl phosphonic acid (F5BnPA) by solution deposition, micro-contact printing and spray coating using PM-IRRAS. In contrast to micro-contact printing and spray coating techniques, 48-168 h solution deposition at both room temperature and 70 degrees C result in contamination- and surface etch-free close-packed monolayers with good reproducibility. SAMs fabricated by micro-contact printing and spray coating are much less well ordered.

  19. Testing expected and perceived service quality in the hotel industry

    OpenAIRE

    Vujko Aleksandra; Gajić Tamara; Mladenovski Milan; Momirski Jovan

    2015-01-01

    Guest satisfaction is the key to retaining existing and attracting new guests. In order to reach this goal, managers in hotels have become aware of the fact that the quality stay is reflected in the unique experiences of the tourists in particular. Guest satisfaction with hotel services can be tested by various methods. In this study, we used a questionnaire technique, in which respondents were guests of the hotel 'Vojvodina', 'Novi Sad' and 'Park' in Novi Sad, then the guests of the hotel 'V...

  20. Thermography During Thermal Test of the Gaia Deployable Sunshield Assembly Qualification Model in the ESTEC Large Space Simulator

    Science.gov (United States)

    Simpson, R.; Broussely, M.; Edwards, G.; Robinson, D.; Cozzani, A.; Casarosa, G.

    2012-07-01

    The National Physical Laboratory (NPL) and The European Space Research and Technology Centre (ESTEC) have performed for the first time successful surface temperature measurements using infrared thermal imaging in the ESTEC Large Space Simulator (LSS) under vacuum and with the Sun Simulator (SUSI) switched on during thermal qualification tests of the GAIA Deployable Sunshield Assembly (DSA). The thermal imager temperature measurements, with radiosity model corrections, show good agreement with thermocouple readings on well characterised regions of the spacecraft. In addition, the thermal imaging measurements identified potentially misleading thermocouple temperature readings and provided qualitative real-time observations of the thermal and spatial evolution of surface structure changes and heat dissipation during hot test loadings, which may yield additional thermal and physical measurement information through further research.

  1. Assembly reliability of CSPs with various chiip sizes by accelerated thermal and mechanical cycling test

    Science.gov (United States)

    Ghaffarian, R.

    2000-01-01

    A JPL-led chip scale package (CSP) Consortium, composed of team members representing government agencies and private companies, recently joined together to pool in-kind resources for developing the quality and reliability of chip scale packages (CSPs) for a variety of projects.

  2. Quality assurance test of a real time radiography system

    International Nuclear Information System (INIS)

    Yadav, R.K.; Rama, R.; Sharma, A.; Kannan, R.

    2005-01-01

    Any radiation generating equipment can be used and marketed in India only after obtaining specific type approval certificate from the Competent Authority i.e. Chairman, Atomic Energy Regulatory Board (AERB), Mumbai. Recently AERB has enforced a directive that the Industrial X-ray machines should also be permitted to use only after getting NOC or type approval. Type approval is granted based upon the satisfactory QA test report of the radiation generating equipment. X-ray machines with Real Time Radiography (RTR) facility are used in industrial radiography for faster inspection of equipment's and products online. A standard test protocol was developed for QA tests of a real time radiography system. This will be helpful for evaluation of an industrial X-ray machine. Also above procedure can be used to check a RTR system each day or a system-qualification can be done when the image quality diminishes as recommended by American Society of Testing Material (ASTM). Various tests carried out on a constant potential 450 kV, 10 mA industrial X-ray machine having real time radiography facility to monitor the products online, is described in this paper. (author)

  3. 1994 Baseline biological studies for the Device Assembly Facility at the Nevada Test Site

    Energy Technology Data Exchange (ETDEWEB)

    Townsend, Y.E. [ed.; Woodward, B.D.; Hunter, R.B.; Greger, P.D.; Saethre, M.B.

    1995-02-01

    This report describes environmental work performed at the Device Assembly Facility (DAF) in 1994 by the Basic Environmental Monitoring and Compliance Program (BECAMP). The DAF is located near the Mojave-Great Basin desert transition zone 27 km north of Mercury. The area immediately around the DAF building complex is a gentle slope cut by 1 to 3 m deep arroyos, and occupied by transitional vegetation. In 1994, construction activities were largely limited to work inside the perimeter fence. The DAF was still in a preoperational mode in 1994, and no nuclear materials were present. The DAF facilities were being occupied so there was water in the sewage settling pond, and the roads and lights were in use. Sampling activities in 1994 represent the first year in the proposed monitoring scheme. The proposed biological monitoring plan gives detailed experimental protocols. Plant, lizard, tortoise, small mammal, and bird surveys were performed in 1994. The authors briefly outline procedures employed in 1994. Studies performed on each taxon are reviewed separately then summarized in a concluding section.

  4. 49 CFR 572.165 - Upper and lower torso assemblies and torso flexion test procedure.

    Science.gov (United States)

    2010-10-01

    ...) ANTHROPOMORPHIC TEST DEVICES Hybrid III Six-Year-Old Weighted Child Test Dummy § 572.165 Upper and lower torso... determine the stiffness effects of the lumbar spine (specified in 49 CFR 572.125(a)), including cable... bushing (specified in 49 CFR 572.125(a)), nut (specified in 49 CFR 572.125(a)), spine box weighting plates...

  5. Force Limiting Vibration Tests Evaluated from both Ground Acoustic Tests and FEM Simulations of a Flight Like Vehicle System Assembly

    Science.gov (United States)

    Smith, Andrew; LaVerde, Bruce; Waldon, James; Hunt, Ron

    2014-01-01

    Marshall Space Flight Center has conducted a series of ground acoustic tests with the dual goals of informing analytical judgment, and validating analytical methods when estimating vibroacoustic responses of launch vehicle subsystems. The process of repeatedly correlating finite element-simulated responses with test-measured responses has assisted in the development of best practices for modeling and post-processing. In recent work, force transducers were integrated to measure interface forces at the base of avionics box equipment. Other force data was indirectly measured using strain gauges. The combination of these direct and indirect force measurements has been used to support and illustrate the advantages of implementing the Force Limiting approach for equipment qualification tests. The comparison of force response from integrated system level tests to measurements at the same locations during component level vibration tests provides an excellent illustration. A second comparison of the measured response cases from the system level acoustic tests to finite element simulations has also produced some principles for assessing the suitability of Finite Element Models (FEMs) for making vibroacoustics estimates. The results indicate that when FEM models are employed to guide force limiting choices, they should include sufficient detail to represent the apparent mass of the system in the frequency range of interest.

  6. Can water quality of tubewells be assessed without chemical testing?

    Science.gov (United States)

    Hoque, Mohammad A.; Butler, Adrian P.

    2016-04-01

    Arsenic is one of the major pollutants found in aquifers on a global scale. The screening of tubewells for arsenic has helped many people to avoid drinking from highly polluted wells in the Bengal Delta (West Bengal and Bangladesh). However, there are still many millions of tubewells in Bangladesh yet to be tested, and a substantial proportion of these are likely to contain excessive arsenic. Due to the level of poverty and lack of infrastructure, it is unlikely that the rest of the tubewells will be tested quickly. However, water quality assessment without needing a chemical testing may be helpful in this case. Studies have found that qualitative factors, such as staining in the tubewell basement and/or on utensils, can indicate subsurface geology and water quality. The science behind this staining is well established, red staining is associated with iron reduction leading to release of arsenic whilst black staining is associated with manganese reduction (any release of arsenic due to manganese reduction is sorbed back on the, yet to be reduced, iron), whereas mixed staining may indicate overlapping manganese and iron reduction at the tubewell screen. Reduction is not uniform everywhere and hence chemical water quality including dissolved arsenic varies from place to place. This is why coupling existing tubewell arsenic information with user derived staining data could be useful in predicting the arsenic status at a particular site. Using well location, depth, along with colour of staining, an assessment of both good (nutrients) and bad (toxins and pathogens) substances in the tubewell could be provided. Social-network technology, combined with increasing use of smartphones, provides a powerful opportunity for both sharing and providing feedback to the user. Here we outline how a simple digital application can couple the reception both qualitative and quantitative tubewell data into a centralised interactive database and provide manipulated feedback to an

  7. Preparation and optimization of self-assembled chondroitin sulfate-nisin nanogel based on quality by design concept.

    Science.gov (United States)

    Mohtashamian, Shahab; Boddohi, Soheil; Hosseinkhani, Saman

    2018-02-01

    Self-assembled nanogel was prepared by electrostatic complexation of two oppositely charged biological macromolecules, which were cationic nisin and anionic chondroitin sulfate (ChS). The critical factors affected the physical properties of ChS-nisin nanogel was screened and optimized by Plackett-Burman design (PB) and central composite design (CCD). The independent factors selected were: concentration ratio of nisin to ChS, injection rate of nisin solution, buffer solvent type, magnetic stirring rate, pH of initial buffer solution, centrifuge-cooling temperature, and centrifuge rotation speed. Among these factors, concentration ratio changed the entrapment efficiency and loading capacity significantly. In addition, the hydrodynamic diameter and loading capacity were significantly influenced by injection rate and pH of initial buffer solution. The optimized nanogel structure was obtained by concentration ratio of 6.4mg/mL nisin to 1mg/mL ChS, pH of buffer solution at 4.6, and nisin solution injection rate of 0.2mL/min. The observed values of dependent responses were close to predicted values confirmed by model from response surface methodology. The results obviously showed that quality by design concept (QbD) could be effectively applied to optimize the developed ChS-nisin nanogel. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Assembly Tests of the First Nb$_{3}$Sn Low-Beta Quadrupole Short Model for the Hi-Lumi LHC

    CERN Document Server

    Pan, H; Cheng, D W; Anderssen, E; Ambrosio, G; Perez, J C; Juchno, M; Ferracin, P; Prestemon, S O

    2016-01-01

    In preparation for the high-luminosity upgrade of the Large Hadron Collider (LHC), the LHC Accelerator Research Program (LARP) in collaboration with CERN is pursuing the development of MQXF: a 150-mm-aperture high-field Nb$_{3}$Sn quadrupole magnet. The development phase starts with the fabrication and test of several short models (1.2-m magnetic length) and will continue with the development of several long prototypes. All of them are mechanically supported using a shell-based support structure, which has been extensively demonstrated on several R&D; models within LARP. The first short model MQXFS-AT has been assembled at LBNL with coils fabricated by LARP and CERN. In this paper, we summarize the assembly process and show how it relies strongly on experience acquired during the LARP 120-mm-aperture HQ magnet series. We present comparison between strain gauges data and finite-element model analysis. Finally, we present the implication of the MQXFS-AT experience on the design of the long prototype support...

  9. In-plant test and evaluation of the neutron collar for verification of PWR fuel assemblies at Resende, Brazil

    International Nuclear Information System (INIS)

    Menlove, H.O.; Marzo, M.A.S.; de Almeida, S.G.; de Almeida, M.C.; Moitta, L.P.M.; Conti, L.F.; de Paiva, J.R.T.

    1985-11-01

    The neutron-coincidence collar has been evaluated for the measurement of pressurized-water reactor (PWR) fuel assemblies at the Fabrica de Elementos Combustiveis plant in Resende, Brazil. This evaluation was part of the cooperative-bilateral-safeguards technical-exchange program between the United States and Brazil. The neutron collar measures the 235 U content per unit length of full fuel assemblies using neutron interrogation and coincidence counting. The 238 U content is measured in the passive mode without the AmLi neutron-interrogation source. The extended evaluation took place over a period of 6 months with both scanning and single-zone measurements. The results of the tests gave a coincidence-response standard deviation of 0.7% (sigma = 1.49% for mass) for the active case and 2.5% for the passive case in 1000-s measurement times. The length measurement in the scanning mode was accurate to 0.77%. The accuracies of different calibration methods were evaluated and compared

  10. WIPP [Waste Isolation Pilot Plant]/SRL in situ tests: Part 2, Pictorial history of MIIT [Materials Interface Interactions Tests] and final MIIT matrices, assemblies, and sample listings

    International Nuclear Information System (INIS)

    Wicks, G.G.; Weinle, M.E.; Molecke, M.A.

    1987-01-01

    In situ testing of Savannah River Plant [SRP] waste glass is an important component in ensuring technical and public confidence in the safety and effective performance of the wasteforms. Savannah River Laboratory [SRL] is currently involved in joint programs involving field testing of SRP waste in Sweden, Belgium, and the United Kingdom. Most recently, this in situ effort has been expanded to include the first field tests to be conducted in the United States, involving burial of a variety of simulated nuclear waste systems. This new effort, called the Materials Interface Interactions Tests or MIIT, is a program jointly conducted by Sandia National Laboratory/Waste Isolation Pilot Plant [WIPP] and SRL. Over 1800 samples, supplied by the United States, France, West Germany, Belgium, Canada, Japan, and the United Kingdom, were buried approximately 650m below the earth's surface in the salt geology at WIPP, near Carlsbad, New Mexico. The MIIT program is one of the largest cooperative efforts ever undertaken in the waste management field; the data produced from these tests are designed to benefit a wide cross-section of the waste management community. An earlier document provided an overview of the WIPP MIIT program and described its place in the waste glass assessment program at Savannah River. This document represents the second in this series and its objectives include: (1) providing a pictorial history of assembly and installation of wasteforms, metals, and geologic samples in WIPP; (2) providing 'finalized and completed' sample matrices for the entire 7-part MIIT program; (3) documenting final sample assemblies by the use of schematic drawings, including each sample, its orientation, and its environment; and (4) providing a complete listing of all samples and the means for managing analyses and resulting data

  11. Benchmark physics tests in the metallic-fuelled assembly ZPPR-15

    International Nuclear Information System (INIS)

    McFarlane, H.F.; Brumbach, S.B.; Carpenter, S.G.; Collins, P.J.

    1987-01-01

    In the last two years a shift in emphasis to inherent safety and economic competitiveness has led to a resurgence in US interest in metallic-alloy fuels for LMRs. Argonne National Laboratory initiated an extensive testing program for metallic-fuelled LMR technology that has included benchmark physics as one component. The tests done in the ZPPR-15 Program produced the first physics results in over 20 years for a metal-composition LMR core

  12. Self-assembly of star micelle into vesicle in solvents of variable quality: the star micelle retains its core-shell nanostructure in the vesicle.

    Science.gov (United States)

    Liu, Nijuan; He, Qun; Bu, Weifeng

    2015-03-03

    Intra- and intermolecular interactions of star polymers in dilute solutions are of fundamental importance for both theoretical interest and hierarchical self-assembly into functional nanostructures. Here, star micelles with a polystyrene corona and a small ionic core bearing platinum(II) complexes have been regarded as a model of star polymers to mimic their intra- and interstar interactions and self-assembled behaviors in solvents of weakening quality. In the chloroform/methanol mixture solvents, the star micelles can self-assemble to form vesicles, in which the star micelles shrink significantly and are homogeneously distributed on the vesicle surface. Unlike the morphological evolution of conventional amphiphiles from micellar to vesicular, during which the amphiphilic molecules are commonly reorganized, the star micelles still retain their core-shell nanostructures in the vesicles and the coronal chains of the star micelle between the ionic cores are fully interpenetrated.

  13. Acceptance testing and quality assurance of Simulix evolution radiotherapy simulator

    International Nuclear Information System (INIS)

    Sinha, Ashutosh; Singh, Navin; Gurjar, Om Prakash; Bagdare, Priyusha

    2015-01-01

    The success of radiotherapy depends on precise treatment simulation and proper patient positioning. The simulator is a conventional radiographic and fluoroscopic system which emulates the geometrical positions of radiotherapy treatment unit. Hence, the acceptance tests and quality assurance (QA) of the simulator are important prior to its commissioning for the safe and precise clinical use. The verification of mechanical and optical readouts, field size, isocenter, optical and radiation field congruence were performed. The X-ray beam parameters were tested for kVp, mAs and consistency of radiation output. The flat panel detector performance was checked with respect to resolution, low contrast sensitivity (LCS), automatic dose rate control (ADRC), and gray image resolution (GIR). Gantry, table, and imaging system collision possibility was checked. Radiation survey around the room was also performed. The field size test for digital readout and on graph paper, the results of isocenter checkup for rotation of gantry, collimator, and couch, and the deviations observed in auto stop for various movements were found within the tolerance limits. Optical field and radiation field was found congruent. All the lasers were found aligned with the established isocenter. Maximum deviation for set and measured kV was found to be 3% in fluoro mode. The maximum deviation observed in mAs was 1.5% in 3-point as well as in 2-point film exposed mode. The X-ray output was found consistent. The results of tests for resolution, LCS, ADRC, and GIR of the flat panel detector were within tolerance limits. All the six safety interlocks were found working. Radiation level around the room was found within the acceptable limits. All the tests carried out were found within the tolerance limits. The data which has been taken in this study will provide basic support to the routine QA of the simulator. (author)

  14. Numerical Analysis Of The Resistance To Pullout Test Of Clinched Assemblies Of Thin Metal Sheets

    International Nuclear Information System (INIS)

    Jomaa, Moez; Billardon, Rene

    2007-01-01

    This paper presents the finite element analysis of the resistance of a clinch point to pullout test -that follows the numerical analysis of the forming process of the point-. The simulations have been validated by comparison with experimental evidences. The influence on the numerical predictions of various computation and process parameters have been evaluated

  15. Application of statistical methods to the testing of nuclear counting assemblies

    International Nuclear Information System (INIS)

    Gilbert, J.P.; Friedling, G.

    1965-01-01

    This report describes the application of the hypothesis test theory to the control of the 'statistical purity' and of the stability of the counting batteries used for measurements on activation detectors in research reactors. The principles involved and the experimental results obtained at Cadarache on batteries operating with the reactors PEGGY and AZUR are given. (authors) [fr

  16. Assembly and Tests of SQ02, a Nb3Sn Racetrack Quadrupole Magnet for LARP

    Energy Technology Data Exchange (ETDEWEB)

    Ferracin, Paolo; Ambrosio, G.; Barzi, E.; Caspi, S.; Dietderich, D.R.; Feher, S.; Gourlay, S.A.; Hafalia, A.R.; Hannaford, C.R.; Lizarazo, J.; Lietzke, A.F.; McInturff, A.D.; Sabbi, G.L.; Zlobin, A.V.

    2007-06-01

    The US LHC Accelerator Research Program (LARP) consists of four US laboratories (BNL, FNAL, LBNL, and SLAC) collaborating with CERN to achieve a successful commissioning of the LHC and to develop the next generation of Interaction Region magnets. In 2004, a large aperture Nb{sub 3}Sn racetrack quadrupole magnet (SQ01) has been fabricated and tested at LBNL. The magnet utilized four subscale racetrack coils and was instrumented with strain gauges on the support structure and directly over the coil's turns. SQ01 exhibited training quenches in two of the four coils and reached a peak field in the conductor of 10.4 T at a current of 10.6 kA. After the test, the magnet was disassembled, inspected with pressure indicating films, and reassembled with minor modifications. A second test (SQ01b) was performed at FNAL and included training studies, strain gauge measurements and magnetic measurements. Magnet inspection, test results, and magnetic measurements are reported and discussed, and a comparison between strain gauge measurements and 3D finite element computations is presented.

  17. Assembly and Tests of SQ02, a Nb3Sn Racetrack Quadrupole Magnet for LARP

    International Nuclear Information System (INIS)

    Ferracin, Paolo; Ambrosio, G.; Barzi, E.; Caspi, S.; Dietderich, D.R.; Feher, S.; Gourlay, S.A.; Hafalia, A.R.; Hannaford, C.R.; Lizarazo, J.; Lietzke, A.F.; McInturff, A.D.; Sabbi, G.L.; Zlobin, A.V.

    2007-01-01

    The US LHC Accelerator Research Program (LARP) consists of four US laboratories (BNL, FNAL, LBNL, and SLAC) collaborating with CERN to achieve a successful commissioning of the LHC and to develop the next generation of Interaction Region magnets. In 2004, a large aperture Nb 3 Sn racetrack quadrupole magnet (SQ01) has been fabricated and tested at LBNL. The magnet utilized four subscale racetrack coils and was instrumented with strain gauges on the support structure and directly over the coil's turns. SQ01 exhibited training quenches in two of the four coils and reached a peak field in the conductor of 10.4 T at a current of 10.6 kA. After the test, the magnet was disassembled, inspected with pressure indicating films, and reassembled with minor modifications. A second test (SQ01b) was performed at FNAL and included training studies, strain gauge measurements and magnetic measurements. Magnet inspection, test results, and magnetic measurements are reported and discussed, and a comparison between strain gauge measurements and 3D finite element computations is presented

  18. Low-cost and versatile thermal test chip for power assemblies assessment and thermometric calibration purposes

    International Nuclear Information System (INIS)

    Jorda, X.; Perpina, X.; Vellvehi, M.; Madrid, F.; Flores, D.; Hidalgo, S.; Millan, J.

    2011-01-01

    Chips specifically designed for thermal tests such as the assessment of packages, are of main interest in Microelectronics. Nevertheless, these test dies are required in relatively low quantities and their price is a limiting factor. This work describes a low-cost thermal test chip, specifically developed for the needs of power electronics. It is based on a poly-silicon heating resistor and a decoupled Pt temperature sensing resistor on the top, allowing to dissipate more than 60 W (170 W/cm 2 ) and reaching temperatures up to 200 o C. Its simple structure allows an easy simulation and modeling. These features have been taken in profit for packaging materials assessment, calibration of temperature measurement apparatus and methods, and validation of thermal models and simulations. - Highlights: → We describe a low-cost thermal test chip developed for power electronics applications. → It integrates a poly-silicon heating resistor and a Pt temperature sensing resistor on the top. → It can dissipate up to 200 W/cm 2 and work up to 200 o C. → It has been used for thermal resistance and conductivity measurement of substrates. → It allowed also the calibration of advanced thermometric equipments.

  19. Faucet: streaming de novo assembly graph construction.

    Science.gov (United States)

    Rozov, Roye; Goldshlager, Gil; Halperin, Eran; Shamir, Ron

    2018-01-01

    We present Faucet, a two-pass streaming algorithm for assembly graph construction. Faucet builds an assembly graph incrementally as each read is processed. Thus, reads need not be stored locally, as they can be processed while downloading data and then discarded. We demonstrate this functionality by performing streaming graph assembly of publicly available data, and observe that the ratio of disk use to raw data size decreases as coverage is increased. Faucet pairs the de Bruijn graph obtained from the reads with additional meta-data derived from them. We show these metadata-coverage counts collected at junction k-mers and connections bridging between junction pairs-contain most salient information needed for assembly, and demonstrate they enable cleaning of metagenome assembly graphs, greatly improving contiguity while maintaining accuracy. We compared Fauceted resource use and assembly quality to state of the art metagenome assemblers, as well as leading resource-efficient genome assemblers. Faucet used orders of magnitude less time and disk space than the specialized metagenome assemblers MetaSPAdes and Megahit, while also improving on their memory use; this broadly matched performance of other assemblers optimizing resource efficiency-namely, Minia and LightAssembler. However, on metagenomes tested, Faucet,o outputs had 14-110% higher mean NGA50 lengths compared with Minia, and 2- to 11-fold higher mean NGA50 lengths compared with LightAssembler, the only other streaming assembler available. Faucet is available at https://github.com/Shamir-Lab/Faucet. rshamir@tau.ac.il or eranhalperin@gmail.com. Supplementary data are available at Bioinformatics online. © The Author 2017. Published by Oxford University Press.

  20. Effect of time and deposition method on quality of phosphonic acid modifier self-assembled monolayers on indium zinc oxide

    Energy Technology Data Exchange (ETDEWEB)

    Sang, Lingzi [Department of Chemistry and Biochemistry, University of Arizona, Tucson, AZ 85721 (United States); Knesting, Kristina M. [Department of Chemistry, University of Washington, Seattle, WA 98195-1700 (United States); Bulusu, Anuradha [School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA 30332 (United States); Sigdel, Ajaya K. [National Renewable Energy Laboratory, Golden, CO 80401 (United States); Giordano, Anthony J.; Marder, Seth R. [School of Chemistry and Biochemistry and Center for Organic Photonics and Electronics, Georgia Institute of Technology, Atlanta, GA 30332-0400 (United States); Berry, Joseph J. [National Renewable Energy Laboratory, Golden, CO 80401 (United States); Graham, Samuel [School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA 30332 (United States); Ginger, David S. [Department of Chemistry, University of Washington, Seattle, WA 98195-1700 (United States); Pemberton, Jeanne E., E-mail: pembertn@email.arizona.edu [Department of Chemistry and Biochemistry, University of Arizona, Tucson, AZ 85721 (United States)

    2016-12-15

    Highlights: • Deposition of phosphonic acid monolayers on oxides from ethanol solutions occurs by rapid adsorption within 10 s with slower equilibration complete in 48 h. • The slower equilibration step involves molecular reorientation and vacancy filling on the oxide surface. • Soak-free deposition by spray coating and microcontact printing do not provide reproducible, fully-covered, uniform monolayers without substrate etching. • Adjustments to exposure time, substrate temperature, and solution/substrate contact efficiency are necessary to optimize soak-free methods. - Abstract: Phosphonic acid (PA) self-assembled monolayers (SAMs) are utilized at critical interfaces between transparent conductive oxides (TCO) and organic active layers in organic photovoltaic devices (OPVs). The effects of PA deposition method and time on the formation of close-packed, high-quality monolayers is investigated here for SAMs fabricated by solution deposition, micro-contact printing, and spray coating. The solution deposition isotherm for pentafluorinated benzylphosphonic acid (F{sub 5}BnPA) on indium-doped zinc oxide (IZO) is studied using polarization modulation-infrared reflection-absorption spectroscopy (PM-IRRAS) at room temperature as a model PA/IZO system. Fast surface adsorption occurs within the first min; however, well-oriented high-quality SAMs are reached only after ∼48 h, presumably through a continual process of molecular adsorption/desorption and monolayer filling accompanied by molecular reorientation. Two other rapid, soak-free deposition techniques, micro-contact printing and spray coating, are also explored. SAM quality is compared for deposition of phenyl phosphonic acid (PPA), F{sub 13}-octylphosphonic acid (F{sub 13}OPA), and pentafluorinated benzyl phosphonic acid (F{sub 5}BnPA) by solution deposition, micro-contact printing and spray coating using PM-IRRAS. In contrast to micro-contact printing and spray coating techniques, 48–168 h solution

  1. ATM Quality of Service Tests for Digitized Video Using ATM Over Satellite: Laboratory Tests

    Science.gov (United States)

    Ivancic, William D.; Brooks, David E.; Frantz, Brian D.

    1997-01-01

    A digitized video application was used to help determine minimum quality of service parameters for asynchronous transfer mode (ATM) over satellite. For these tests, binomially distributed and other errors were digitally inserted in an intermediate frequency link via a satellite modem and a commercial gaussian noise generator. In this paper, the relation- ship between the ATM cell error and cell loss parameter specifications is discussed with regard to this application. In addition, the video-encoding algorithms, test configurations, and results are presented in detail.

  2. The Test for Flow Characteristics of Tubular Fuel Assembly(II) - Experimental results and CFD analysis

    International Nuclear Information System (INIS)

    Park, Jong Hark; Chae, H. T.; Park, C.; Kim, H.

    2006-12-01

    A test facility had been established for the experiment of velocity distribution and pressure drop in a tubular fuel. A basic test had been conducted to examine the performance of the test loop and to verify the accuracy of measurement by pitot-tube. In this report, test results and CFD analysis for the hydraulic characteristics of a tubular fuel, following the previous tests, are described. Coolant velocities in all channels were measured using pitot-tube and the effect of flow rate change on the velocity distribution was also examined. The pressure drop through the tubular fuel was measured for various flow rates in range of 1 kg/s to 21 kg/s to obtain a correlation of pressure drop with variation of flow rate. In addition, a CFD(Computational Fluid Dynamics) analysis was also done to find out the hydraulic characteristics of tubular fuel such as velocity distribution and pressure drop. As the results of CFD analysis can give us a detail insight on coolant flow in the tubular fuel, the CFD method is a very useful tool to understand the flow structure and phenomena induced by fluid flow. The CFX-10, a commercial CFD code, was used in this study. The two results by the experiment and the CFD analysis were investigated and compared with each other. Overall trend of velocity distribution by CFD analysis was somewhat different from that of experiment, but it would be reasonable considering measurement uncertainties. The CFD prediction for pressure drop of a tubular fuel shows a tolerably good agreement with experiment within 8% difference

  3. Soldering in electronics assembly

    CERN Document Server

    Judd, Mike

    2013-01-01

    Soldering in Electronics Assembly discusses several concerns in soldering of electronic assemblies. The book is comprised of nine chapters that tackle different areas in electronic assembly soldering. Chapter 1 discusses the soldering process itself, while Chapter 2 covers the electronic assemblies. Chapter 3 talks about solders and Chapter 4 deals with flux. The text also tackles the CS and SC soldering process. The cleaning of soldered assemblies, solder quality, and standards and specifications are also discussed. The book will be of great use to professionals who deal with electronic assem

  4. Improving Quality of Seal Leak Test Product using Six Sigma

    Science.gov (United States)

    Luthfi Malik, Abdullah; Akbar, Muhammad; Irianto, Dradjad

    2016-02-01

    Seal leak test part is a polyurethane material-based product. Based on past data, defect level of this product was 8%, higher than the target of 5%. Quality improvement effort was done using six sigma method that included phases of define, measure, analyse, improve, and control. In the design phase, a Delphi method was used to identify factors that were critical to quality. In the measure phase, stability and process capability was measured. Fault tree analysis (FTA) and failure mode and effect analysis (FMEA) were used in the next phase to analize the root cause and to determine the priority issues. Improve phase was done by compiling, selecting, and designing alternative repair. Some improvement efforts were identified, i.e. (i) making a checklist for maintenance schedules, (ii) making written reminder form, (iii) modifying the SOP more detail, and (iv) performing a major service to the vacuum machine. To ensure the continuity of improvement efforts, some control activities were executed, i.e. (i) controlling, monitoring, documenting, and setting target frequently, (ii) implementing reward and punishment system, (iii) adding cleaning tool, and (iv) building six sigma organizational structure.

  5. Development and validation of a Chinese music quality rating test.

    Science.gov (United States)

    Cai, Yuexin; Zhao, Fei; Zheng, Yiqing

    2013-09-01

    The present study aims to develop and validate a Chinese music quality rating test (MQRT). In Experiment 1, 22 music pieces were initially selected and paired as a 'familiar music piece' and 'unfamiliar music piece' based on familiarities amongst the general public in the categories of classical music (6), Chinese folk music (8), and pop music (8). Following the selection criteria, one pair of music pieces from each music category was selected and used for the MQRT in Experiment 2. In Experiment 2, the MQRT was validated using these music pieces in the categories 'Pleasantness', 'Naturalness', 'Fullness', 'Roughness', and 'Sharpness'. Seventy-two adult participants and 30 normal-hearing listeners were recruited in Experiments 1 and 2, respectively. Significant differences between the familiar and unfamiliar music pieces were found in respect of pleasantness rating for folk and pop music pieces as well as in sharpness rating for pop music pieces. The comparison of music category effect on MQRT found significant differences in pleasantness, fullness, and sharpness ratings. The Chinese MQRT developed in the present study is an effective tool for assessing music quality.

  6. Improving Quality of Seal Leak Test Product using Six Sigma

    International Nuclear Information System (INIS)

    Malik, Abdullah Luthfi; Akbar, Muhammad; Irianto, Dradjad

    2016-01-01

    Seal leak test part is a polyurethane material-based product. Based on past data, defect level of this product was 8%, higher than the target of 5%. Quality improvement effort was done using six sigma method that included phases of define, measure, analyse, improve, and control. In the design phase, a Delphi method was used to identify factors that were critical to quality. In the measure phase, stability and process capability was measured. Fault tree analysis (FTA) and failure mode and effect analysis (FMEA) were used in the next phase to analize the root cause and to determine the priority issues. Improve phase was done by compiling, selecting, and designing alternative repair. Some improvement efforts were identified, i.e. (i) making a checklist for maintenance schedules, (ii) making written reminder form, (iii) modifying the SOP more detail, and (iv) performing a major service to the vacuum machine. To ensure the continuity of improvement efforts, some control activities were executed, i.e. (i) controlling, monitoring, documenting, and setting target frequently, (ii) implementing reward and punishment system, (iii) adding cleaning tool, and (iv) building six sigma organizational structure. (paper)

  7. Relevant criteria for testing the quality of turbulence models

    DEFF Research Database (Denmark)

    Frandsen, Sten Tronæs; Ejsing Jørgensen, Hans; Sørensen, J.D.

    2007-01-01

    Seeking relevant criteria for testing the quality of turbulence models, the scale of turbulence and the gust factor have been estimated from data and compared with predictions from first-order models of these two quantities. It is found that the mean of the measured length scales is approx. 10......% smaller than the IEC model, for wind turbine hub height levels. The mean is only marginally dependent on trends in time series. It is also found that the coefficient of variation of the measured length scales is about 50%. 3sec and 10sec pre-averaging of wind speed data are relevant for MW-size wind...... turbines when seeking wind characteristics that correspond to one blade and the entire rotor, respectively. For heights exceeding 50-60m the gust factor increases with wind speed. For heights larger the 60-80m, present assumptions on the value of the gust factor are significantly conservative, both for 3...

  8. Test of the palladium diffuser in the JAERI Fuel Cleanup System in the Tritium Systems Test Assembly

    International Nuclear Information System (INIS)

    Konishi, Satoshi; Hayashi, Takumi; O-hira, Shigeru

    1993-03-01

    The JAERI Fuel Cleanup System (JFCU) is a major subsystem of the TSTA simulated fusion fuel loop. The palladium diffuser, that accepts simulated plasma exhaust and purifies the hydrogen isotopes mixture for the feed to the Isotope Separation System, was tested with deuterium to investigate the characteristics of the components. Permeation flow rate is a linear function of the difference of the square root of the pressure across the palladium alloy membrane. However at the low pressure region, an impediment on the permeation was observed. It was suspected to be caused by the impurity adsorbed on the surface of the permeated side of the membrane and was reduced by oxidation treatment. (author)

  9. Quality assurance testing of acoustic doppler current profiler transform matrices

    Science.gov (United States)

    Armstrong, Brandy; Fulford, Janice M.; Thibodeaux, Kirk G.

    2015-01-01

    The U.S. Geological Survey (USGS) Hydrologic Instrumentation Facility (HIF) is nationally responsible for the design, testing, evaluation, repair, calibration, warehousing, and distribution of hydrologic instrumentation in use within the USGS Water Mission Area (WMA). The HIF's Hydraulic Laboratory has begun routine quality assurance (QA) testing and documenting the performance of every USGS WMA acoustic Doppler current profiler (ADCP) used for making velocity and discharge measurements. All existing ADCPs are being registered and tracked in a database maintained by the HIF, and called for QA checks in the HIF's Hydraulic Laboratory on a 3- year cycle. All new ADCPs purchased directly from the manufacturer as well as ADCPs sent to the HIF or the manufacturer for repair are being registered and tracked in the database and QA checked in the laboratory before being placed into service. Meters failing the QA check are sent directly to the manufacturer for repairs and rechecked by HIF or removed from service. Although this QA program is specific to the SonTek1 and Teledyne RD Instruments1, ADCPs most commonly used within the WMA, it is the intent of the USGS Office of Surface Water and the HIF to expand this program to include all bottom tracking ADCPs as they become available and more widely used throughout the WMA. As part of the HIF QA process, instruments are inspected for physical damage, the instrument must pass the ADCP diagnostic self-check tests, the temperature probe must be within ± 2 degrees Celsius of a National Institute of Standards and Technology traceable reference thermometer and the distance made good over a fixed distance must meet the manufacturer's specifications (+/-0.25% or +/-1% difference). The transform matrix is tested by conducting distance-made-good (DMG) tests comparing the straight-line distance from bottom tracking to the measured tow-track distance. The DMG test is conducted on each instrument twice in the forward and reverse

  10. ADIMEW: Fracture assessment and testing of an aged dissimilar metal weld pipe assembly

    International Nuclear Information System (INIS)

    Wintle, J.B.; Hayes, B.; Goldthorpe, M.R.

    2004-01-01

    ADIMEW (Assessment of Aged Piping Dissimilar Metal Weld Integrity) was a three-year collaborative research programme carried out under the EC 5th Framework Programme. The objective of the study was to advance the understanding of the behaviour and safety assessment of defects in dissimilar metal welds between pipes representative of those found in nuclear power plant. ADIMEW studied and compared different methods for predicting the behaviour of defects located near the fusion boundaries of dissimilar metal welds typically used to join sections of austenitic and ferritic piping operating at high temperature. Assessment of such defects is complicated by issues that include: severe mis-match of yield strength of the constituent parent and weld metals, strong gradients of material properties, the presence of welding residual stresses and mixed mode loading of the defect. The study includes the measurement of material properties and residual stresses, predictive engineering analysis and validation by means of a large-scale test. The particular component studied was a 453mm diameter pipe that joins a section of type A508 Class 3 ferritic pipe to a section of type 316L austenitic pipe by means of a type 308 austenitic weld with type 308/309L buttering laid on the ferritic pipe. A circumferential, surface-breaking defect was cut using electro discharge machining into the 308L/309L weld buttering layer parallel to the fusion line. The test pipe was subjected to four-point bending to promote ductile tearing of the defect. This paper presents the results of TWI contributions to ADIMEW including: fracture toughness testing, residual stress measurements and assessments of the ADIMEW test using elastic-plastic, cracked body, finite element analysis. (orig.)

  11. The Preparation of the Cryomagnets and the Assembly of the LHC Test String 2

    CERN Document Server

    Andujar, O; Calzas-Rodriguez, C; Cruikshank, P; Desebe, O; Dobers, T; Jacquemod, A; Kos, N; Lepeule, P; Maan, W; Missiaen, D; Parma, Vittorio; Riddone, G; Rodríguez-Mateos, F; Rohmig, P; Saban, R I; Schneider, G; Serio, L; Skoczen, Blazej; Tock, J P; Veness, R J M; Vuitton, C

    2001-01-01

    The numerous complex activities required to prepare the cryomagnets for the installation in String 2 are described. These include the configuration of the mechanical interfaces, thee conditioning of the beam tubes, the installation of beam screens and the instrumentation as well as the final checks. The preparation of the cryomagnets for String 2 has been a dress rehearsal for the preparation that the cryomagnets will undergo before their installation in the tunnel. After a description of the interconnection procedures of the components for String 2, the tests carried-out to release the String for operation are described. A brief account of the lessons learnt is also given.

  12. Tritium experiments on components for fusion fuel processing at the Tritium Systems Test Assembly

    International Nuclear Information System (INIS)

    Konishi, S.; Yoshida, H.; Naruse, Y.; Carlson, R.V.; Binning, K.E.; Bartlit, J.R.; Anderson, J.L.

    1990-01-01

    Under a collaborative agreement between US and Japan, two tritium processing components, a palladium diffuser and a ceramic electrolysis cell have been tested with tritium for application to a Fuel Cleanup System (FCU) for plasma exhaust processing at the Los Alamos National Laboratory. The fundamental characteristics, compatibility with tritium, impurities effects with tritium, and long-term behavior of the components, were studied over a three year period. Based on these studies, an integrated process loop, ''JAERI Fuel Cleanup System'' equipped with above components was installed at the TSTA for full scale demonstration of the plasma exhaust reprocessing

  13. LHCb VErtex LOcator module characterisation and long term quality assurance tests

    CERN Document Server

    Bates, A; Doherty, F; Dumps, R; Dwyer, L; Gersabeck, M; Marinho, 1, F; Melone, J; Parkes, C; Saavedra, A; Tobin, M; Viret, S

    2009-01-01

    LHCb is the dedicated b-physics experiment of the LHC. Its vertex detector, the VErtex LOcator (VELO), will operate in a harsh radiation environment with limited access due to its proximity to the LHC beam. To ensure the long term operation and performance, every module was required to pass a set of quality assurance tests. These were specifically developed for the VELO modules to take into account their operational environment and assembly steps. Each VELO module was rigorously inspected, tested and thermally cycled in the Glasgow module burn-in procedures. This paper provides details of the burn-in procedures and summarises the main results that were found. Some of the major results presented in this paper are: the full characterisation of the leakage currents; identification of bad channels; and signal to noise measurements. A few minor problems were identified through visual inspections of the modules and the feedback into the production process proved critical. As a result of the electrical and thermal t...

  14. Quality Improvement Intervention for Reduction of Redundant Testing

    Directory of Open Access Journals (Sweden)

    Alan M. Ducatman MD, MS

    2017-05-01

    Full Text Available Laboratory data are critical to analyzing and improving clinical quality. In the setting of residual use of creatine kinase M and B isoenzyme testing for myocardial infarction, we assessed disease outcomes of discordant creatine kinase M and B isoenzyme +/troponin I (− test pairs in order to address anticipated clinician concerns about potential loss of case-finding sensitivity following proposed discontinuation of routine creatine kinase and creatine kinase M and B isoenzyme testing. Time-sequenced interventions were introduced. The main outcome was the percentage of cardiac marker studies performed within guidelines. Nonguideline orders dominated at baseline. Creatine kinase M and B isoenzyme testing in 7496 order sets failed to detect additional myocardial infarctions but was associated with 42 potentially preventable admissions/quarter. Interruptive computerized soft stops improved guideline compliance from 32.3% to 58% ( P 80% ( P < .001 with peer leadership that featured dashboard feedback about test order performance. This successful experience was recapitulated in interrupted time series within 2 additional services within facility 1 and then in 2 external hospitals (including a critical access facility. Improvements have been sustained postintervention. Laboratory cost savings at the academic facility were estimated to be ≥US$635 000 per year. National collaborative data indicated that facility 1 improved its order patterns from fourth to first quartile compared to peer norms and imply that nonguideline orders persist elsewhere. This example illustrates how pathologists can provide leadership in assisting clinicians in changing laboratory ordering practices. We found that clinicians respond to local laboratory data about their own test performance and that evidence suggesting harm is more compelling to clinicians than evidence of cost savings. Our experience indicates that interventions done at an academic facility can be readily

  15. Transcriptome assembly and analysis of Tibetan Hulless Barley (Hordeum vulgare L. var. nudum developing grains, with emphasis on quality properties.

    Directory of Open Access Journals (Sweden)

    Xin Chen

    Full Text Available BACKGROUND: Hulless barley is attracting increasing attention due to its unique nutritional value and potential health benefits. However, the molecular biology of the barley grain development and nutrient storage are not well understood. Furthermore, the genetic potential of hulless barley has not been fully tapped for breeding. METHODOLOGY/PRINCIPAL FINDINGS: In the present study, we investigated the transcriptome features during hulless barley grain development. Using Illumina paired-end RNA-Sequencing, we generated two data sets of the developing grain transcriptomes from two hulless barley landraces. A total of 13.1 and 12.9 million paired-end reads with lengths of 90 bp were generated from the two varieties and were assembled to 48,863 and 45,788 unigenes, respectively. A combined dataset of 46,485 All-Unigenes were generated from two transcriptomes with an average length of 542 bp, and 36,278 among were annotated with gene descriptions, conserved protein domains or gene ontology terms. Furthermore, sequences and expression levels of genes related to the biosynthesis of storage reserve compounds (starch, protein, and β-glucan were analyzed, and their temporal and spatial patterns were deduced from the transcriptome data of cultivated barley Morex. CONCLUSIONS/SIGNIFICANCE: We established a sequences and functional annotation integrated database and examined the expression profiles of the developing grains of Tibetan hulless barley. The characterization of genes encoding storage proteins and enzymes of starch synthesis and (1-3;1-4-β-D-glucan synthesis provided an overview of changes in gene expression associated with grain nutrition and health properties. Furthermore, the characterization of these genes provides a gene reservoir, which helps in quality improvement of hulless barley.

  16. Final configuration with assembly assessment of the 100 kV high voltage bushing for the Indian test facility

    International Nuclear Information System (INIS)

    Sharma, Dheeraj Kumar; Shah, Sejal; Venkata Nagaraju, M.; Bandyopadhyay, Mainak; Rotti, Chandramouli; Chakraborty, Arun Kumar

    2015-01-01

    The Indian Test Facility (INTF) of Neutral Beam (NB) system is an Indian voluntary effort for the full characterization of the diagnostic neutral beam which is the part of ITER's neutral beam system. The design activities of INTF NB system are completed. The INTF High Voltage Bushing (HVB), which is one of the component of NB system, is designed to connect all the required feedlines, e.g. electrical busbars, RF co-axial lines, diagnostic lines and hydraulic and gas feed lines, carried by the transmission line from the HV deck to the Beam Source of NB system. It forms the primary vacuum boundary and provides 100 kV isolation for INTF beam operation. The entire feedlines pass through a metallic plate of HVB called Dished Head (DH) where all the feedlines converge. The overall diameter of DH is 847 mm which is governed by the diameter of the Porcelain insulator which is meant for 100 kV isolation. The effective diameter where all the feedlines converge at the dished head is ∼ 600 mm which is quite a challenge to accommodate 26 feedlines each of average diameter 60 mm. Electrical feedlines require Vacuum-Electrical feedthroughs for voltage isolation whereas water and gas lines are considered to be directly welded with the DH except one water line which requires 12 kV voltage isolation with respect to DH. For RF lines, different scheme is considered which includes separate Electrical Feedthrough and Vacuum Barrier. To provide connection to electrical cables of heaters and thermocouples, 4 numbers of multipin vacuum compatible electrical feedthroughs are provided which can accommodate ∼250 cables. Due to space constraints, Vacuum-Electrical Feedthroughs are considered to be welded with the DH and therefore they shall be of metal-ceramic-metal configuration to allow welding. To avoid undue loading on the ceramic part, the feedlines are supported additionally at DH using vacuum compatible and electrically insulating material. One more important aspect of the INTF

  17. Recent palladium membrane reactor development at the tritium systems test assembly

    International Nuclear Information System (INIS)

    Scott, W.R.; Birdsell, S.A.; Wilhelm, R.C.

    1995-01-01

    The palladium membrane reactor (PMR) is being investigated as a means for recovering hydrogen isotopes (including tritium) from compounds such as water and methane. Previous work with protiated water and methane showed that this device can be used to obtain high hydrogen recovery efficiencies using a single processing pass and with essentially no waste production. With these successful proof-of-principle results completed, recent work has focused on PMR development. This included studies of various geometries and testing with tritium. The results, which are reported here, have led to a better understanding of the PMR and will lead to the ultimate goal of building a production PMR and putting it into practical tritium processing service. 3 refs., 5 figs., 1 tab

  18. Monitoring Quality Across Home Visiting Models: A Field Test of Michigan's Home Visiting Quality Assurance System.

    Science.gov (United States)

    Heany, Julia; Torres, Jennifer; Zagar, Cynthia; Kostelec, Tiffany

    2018-06-05

    Introduction In order to achieve the positive outcomes with parents and children demonstrated by many home visiting models, home visiting services must be well implemented. The Michigan Home Visiting Initiative developed a tool and procedure for monitoring implementation quality across models referred to as Michigan's Home Visiting Quality Assurance System (MHVQAS). This study field tested the MHVQAS. This article focuses on one of the study's evaluation questions: Can the MHVQAS be applied across models? Methods Eight local implementing agencies (LIAs) from four home visiting models (Healthy Families America, Early Head Start-Home Based, Parents as Teachers, Maternal Infant Health Program) and five reviewers participated in the study by completing site visits, tracking their time and costs, and completing surveys about the process. LIAs also submitted their most recent review by their model developer. The researchers conducted participant observation of the review process. Results Ratings on the MHVQAS were not significantly different between models. There were some differences in interrater reliability and perceived reliability between models. There were no significant differences between models in perceived validity, satisfaction with the review process, or cost to participate. Observational data suggested that cross-model applicability could be improved by assisting sites in relating the requirements of the tool to the specifics of their model. Discussion The MHVQAS shows promise as a tool and process to monitor implementation quality of home visiting services across models. The results of the study will be used to make improvements before the MHVQAS is used in practice.

  19. Testing Gravity via Lunar Laser Ranging: Maximizing Data Quality

    Science.gov (United States)

    Murphy, Thomas

    Apache Observatory and from a high-quality Global Positioning System (GPS) station 2.5 km away, will greatly improve our understanding of the instantaneous location of the Observatory with respect to the Earth’s center of mass (needed for the gravitational tests) by exposing subtle Earth dynamics that must be incorporated into the model. In addition to dramatic improvements in the classical gravitational tests listed above, APOLLO will permit exploration of new ideas in physics relating to dark energy, extra dimensions, and violations of Lorentz Invariance. This proposal will have two thrusts: to continue acquiring APOLLO data, thereby probing longer-period terms in the lunar orbit; and to design and construct an absolute calibration system that can either verify APOLLO data accuracy and stability or expose elements in need of attention. APOLLO has been effective at public outreach and education not only by direct involvement with students and underrepresented groups, but also via news articles, magazine articles, radio interviews, and appearances on popular television shows. This level of media attention should continue into the future, given the appealing combination of tests of Einstein's gravity, the legendary lunar landings, and remarkable technology.

  20. South Coast Air Quality Management District Truck Testing | Transportation

    Science.gov (United States)

    Research | NREL South Coast Air Quality Management District Truck Evaluation South Coast Air Quality Management District Truck Evaluation Photo of heavy-duty truck cab. Electric drayage truck Cargo Transportation project, conducted in partnership with the South Coast Air Quality Management

  1. Solid Oxide Cell and Stack Testing, Safety and Quality Assurance (SOCTESQA)

    DEFF Research Database (Denmark)

    Auer, C.; Lang, M.; Couturier, K.

    2015-01-01

    In the EU-funded project “SOCTESQA” partners from Europe and Singapore are working together to develop uniform and industry wide test procedures and protocols for solid oxide cells and stacks SOC cell/stack assembly. New application fields which are based on the operation of the SOC cell/stack as......In the EU-funded project “SOCTESQA” partners from Europe and Singapore are working together to develop uniform and industry wide test procedures and protocols for solid oxide cells and stacks SOC cell/stack assembly. New application fields which are based on the operation of the SOC cell...

  2. Testing expected and perceived service quality in the hotel industry

    Directory of Open Access Journals (Sweden)

    Vujko Aleksandra

    2015-01-01

    Full Text Available Guest satisfaction is the key to retaining existing and attracting new guests. In order to reach this goal, managers in hotels have become aware of the fact that the quality stay is reflected in the unique experiences of the tourists in particular. Guest satisfaction with hotel services can be tested by various methods. In this study, we used a questionnaire technique, in which respondents were guests of the hotel 'Vojvodina', 'Novi Sad' and 'Park' in Novi Sad, then the guests of the hotel 'Vojvodina' and 'Gold Class' in Zrenjanin, as well as the guests of the hotel 'Brothers Sekulic' in Zlatibor. The respondents were asked to evaluate various aspects of the business environment, employees' attitude towards guests, taste and variety of food and beverages. Data are presented in tables with brief comments. Based on the analysis of dependent and independent variables, we concluded that the physical features of a hotel, as well as the guest-employee relationship, are primarily related to the personal experience. Guests were the least satisfied with the hotel bar. These pieces of information are crucial for the hotel enterprises and contribute to the advancement of business through the adjustment of the product to the needs of the customer.

  3. Testing the quality of underground transport in Bucharest

    Directory of Open Access Journals (Sweden)

    Statescu Alexandru

    2017-07-01

    Full Text Available In a city with overcrowded traffic, a component of the common transport is Bucharest transportation of metro (subway passenger transport on the railway network underground and surface and is the core activity of METROREX S.A. The company aims each year a greater number of passengers according to the charts of the movement of subway trains to ensure adequate transport capacity as required and optimal conditions of comfort and safety. Each year, the company aims to find out the opinion of passengers on the transport conditions and, in this respect, organize a survey with the aim of testing the quality of underground transport in Bucharest in 16 subway stations considered to be representative. In this paper I intend to do an analysis using statistical research methods, of the quality of underground transport in Bucharest, using data from the survey conducted in the year 2014. Data collection in the stations was realized through 32 operators, by 2 in each station (one in each direction of travel by completing questionnaires (using interview technique or face to face technique, using a sample considered representative of 2,400 travelers with a margin of error of ± 2% on a 95% probability level. Data collection was made during the period when passenger traffic is large enough to provide a good representation of data and cover the entire program running underground. The questionnaire contains eight questions that have allowed those who responded to the survey to fit in the time between trains in circulation. In 2016, the structure of the questionnaire was modified, questions were modified for a more effective assessment of characteristics of observation. The answers to the questions contained in the questionnaire were collected by operators in the 16 subway stations: Piața Unirii 1 and 2, Piața Victoriei 1 and 2, Dristor 2, Nicolae Grigorescu, Universitate, Piața Sudului, Pipera, Eroilor, Gara de Nord 1, Obor, Crângași, Pantelimon, Parc Bazilescu

  4. In vitro assembly into virus-like particles is an intrinsic quality of Pichia pastoris derived HCV core protein

    International Nuclear Information System (INIS)

    Acosta-Rivero, Nelson; Rodriguez, Armando; Musacchio, Alexis; Falcon, Viviana; Suarez, Viana M.; Martinez, Gillian; Guerra, Ivis; Paz-Lago, Dalila; Morera, Yanelys; Rosa, Maria C. de la; Morales-Grillo, Juan; Duenas-Carrera, Santiago

    2004-01-01

    Different variants of hepatitis C virus core protein (HCcAg) have proved to self-assemble in vitro into virus-like particles (VLPs). However, difficulties in obtaining purified mature HCcAg have limited these studies. In this study, a high degree of monomeric HCcAg purification was accomplished using chromatographic procedures under denaturing conditions. Size exclusion chromatography and sucrose density gradient centrifugation of renatured HCcAg (in the absence of structured RNA) under reducing conditions suggested that it assembled into empty capsids. The electron microscopy analysis of renatured HCcAg showed the presence of spherical VLPs with irregular shapes and an average diameter of 35 nm. Data indicated that HCcAg monomers assembled in vitro into VLPs in the absence of structured RNA, suggesting that recombinant HCcAg used in this work contains all the information necessary for the assembly process. However, they also suggest that some cellular factors might be required for the proper in vitro assembly of capsids

  5. Dynamic behaviour of diagnostic assemblies

    International Nuclear Information System (INIS)

    Pecinka, L.

    1980-01-01

    The methodology is shown of calculating the frequency spectrum of a diagnostic assembly. The oscillations of the assembly as a whole, of a fuel rod bundle, the assembly jacket and of the individual rods in the bundle were considered. The manufacture is suggested of a model assembly which would be used for testing forced vibrations using an experimental water loop. (M.S.)

  6. Prediction of Pressing Quality for Press-Fit Assembly Based on Press-Fit Curve and Maximum Press-Mounting Force

    Directory of Open Access Journals (Sweden)

    Bo You

    2015-01-01

    Full Text Available In order to predict pressing quality of precision press-fit assembly, press-fit curves and maximum press-mounting force of press-fit assemblies were investigated by finite element analysis (FEA. The analysis was based on a 3D Solidworks model using the real dimensions of the microparts and the subsequent FEA model that was built using ANSYS Workbench. The press-fit process could thus be simulated on the basis of static structure analysis. To verify the FEA results, experiments were carried out using a press-mounting apparatus. The results show that the press-fit curves obtained by FEA agree closely with the curves obtained using the experimental method. In addition, the maximum press-mounting force calculated by FEA agrees with that obtained by the experimental method, with the maximum deviation being 4.6%, a value that can be tolerated. The comparison shows that the press-fit curve and max press-mounting force calculated by FEA can be used for predicting the pressing quality during precision press-fit assembly.

  7. Recommendations for quality improvement in genetic testing for cystic fibrosis European Concerted Action on Cystic Fibrosis

    NARCIS (Netherlands)

    Dequeker, E; Cuppens, H; Dodge, J; Estivill, [No Value; Goossens, M; Pignatti, PF; Scheffer, H; Schwartz, M; Schwarz, M; Tummler, B; Cassiman, JJ

    These recommendations for quality improvement of cystic fibrosis genetic diagnostic testing provide general guidelines for the molecular genetic testing of cystic fibrosis in patients/individuals. General strategies for testing as well as guidelines for laboratory procedures, internal and external

  8. Partial Defect Verification of Spent Fuel Assemblies by PDET: Principle and Field Testing in Interim Spent Fuel Storage Facility (CLAB) in Sweden

    Energy Technology Data Exchange (ETDEWEB)

    Ham, Y.S.; Kerr, P.; Sitaraman, S.; Swan, R. [Global Security Directorate, Lawrence Livermore National Laboratory, Livermore, CA 94550 (United States); Rossa, R. [SCK-CEN, Mol (Belgium); Liljenfeldt, H. [SKB in Oskarshamn (Sweden)

    2015-07-01

    The need for the development of a credible method and instrument for partial defect verification of spent fuel has been emphasized over a few decades in the safeguards communities as the diverted spent fuel pins can be the source of nuclear terrorism or devices. The need is increasingly more important and even urgent as many countries have started to transfer spent fuel to so called 'difficult-to-access' areas such as dry storage casks, reprocessing or geological repositories. Partial defect verification is required by IAEA before spent fuel is placed into 'difficult-to-access' areas. Earlier, Lawrence Livermore National Laboratory (LLNL) has reported the successful development of a new, credible partial defect verification method for pressurized water reactor (PWR) spent fuel assemblies without use of operator data, and further reported the validation experiments using commercial spent fuel assemblies with some missing fuel pins. The method was found to be robust as the method is relatively invariant to the characteristic variations of spent fuel assemblies such as initial fuel enrichment, cooling time, and burn-up. Since then, the PDET system has been designed and prototyped for 17x17 PWR spent fuel assemblies, complete with data acquisition software and acquisition electronics. In this paper, a summary description of the PDET development followed by results of the first successful field testing using the integrated PDET system and actual spent fuel assemblies performed in a commercial spent fuel storage site, known as Central Interim Spent fuel Storage Facility (CLAB) in Sweden will be presented. In addition to partial defect detection initial studies have determined that the tool can be used to verify the operator declared average burnup of the assembly as well as intra-assembly burnup levels. (authors)

  9. Some auxiliary technology equipment for ATLAS hadron calorimeter module and submodule manipulations and the quality control of the assembled module

    International Nuclear Information System (INIS)

    Budagov, Yu.; Lebedev, A.; Lomakin, Yu.; Romanov, V.; Rusakovich, N.; Shchelchkov, A.; Sisakyan, A.; Sorokina, Yu.; Topilin, N.; Kul'chitskij, Yu.

    1997-01-01

    Describing of the auxiliary technology equipment for the submodule and module manipulations is presented. The results of the 0-module beam incoming control are given. The variations of the assembled module control measurements are described. The description of the construction for the 0-module transportation is presented

  10. A high-quality carrot genome assembly provides new insights into carotenoid accumulation and asterid genome evolution

    Science.gov (United States)

    We report a chromosome-scale assembly and analysis of the Daucus carota genome, an important source of provitamin A in the human diet and the first sequenced genome among members of the Euasterid II clade. We characterized two new polyploidization events, both occurring after the divergence of carro...

  11. Reference quality assembly of the 3.5 Gb genome of Capsicum annuum form a single linked-read library

    Science.gov (United States)

    Linked-Read sequencing technology has recently been employed successfully for de novo assembly of multiple human genomes, however the utility of this technology for complex plant genomes is unproven. We evaluated the technology for this purpose by sequencing the 3.5 gigabase (Gb) diploid pepper (Cap...

  12. Quality assurance testing on video games : The importance and impact of a misunderstood industry

    OpenAIRE

    Ruuska, Essi

    2015-01-01

    The aim of this research was to provide a more holistic insight of the video game quality assurance industry to video game industry professionals and prospective employees in order to promote the importance and impact of quality assurance testing in video games. The motive for this thesis came from the author's work experience in video game quality assurance testing, and from realizing how little is known about the industry. The research question was defined as 'what is video game quality ass...

  13. Ballistic Resistance of Armored Passenger Vehicles: Test Protocols and Quality Methods

    Energy Technology Data Exchange (ETDEWEB)

    Jeffrey M. Lacy; Robert E. Polk

    2005-07-01

    This guide establishes a test methodology for determining the overall ballistic resistance of the passenger compartment of assembled nontactical armored passenger vehicles (APVs). Because ballistic testing of every piece of every component of an armored vehicle is impractical, if not impossible, this guide describes a testing scheme based on statistical sampling of exposed component surface areas. Results from the test of the sampled points are combined to form a test score that reflects the probability of ballistic penetration into the passenger compartment of the vehicle.

  14. VERIFICATION TESTING OF AIR POLLUTION CONTROL TECHNOLOGY QUALITY MANAGEMENT PLAN

    Science.gov (United States)

    This document is the basis for quality assurance for the Air Pollution Control Technology Verification Center (APCT Center) operated under the U.S. Environmental Protection Agency (EPA). It describes the policies, organizational structure, responsibilities, procedures, and qualit...

  15. Framework and indicator testing protocol for developing and piloting quality indicators for the UK quality and outcomes framework

    NARCIS (Netherlands)

    Campbell, S.M.; Kontopantelis, E.; Hannon, K.; Burke, M.; Barber, A.; Lester, H.E.

    2011-01-01

    BACKGROUND: Quality measures should be subjected to a testing protocol before being used in practice using key attributes such as acceptability, feasibility and reliability, as well as identifying issues derived from actual implementation and unintended consequences. We describe the methodologies

  16. Solid Oxide Cell and Stack Testing, Safety and Quality Assurance (SOCTESQA)

    OpenAIRE

    Auer, Corinna; Lang, Michael; Couturier, Karine; Nielsen, Eva Ravn; Mc Phail, Stephen; Tsotridis, Georgios; FU, Qingxi; Chan, Siew Hwa

    2015-01-01

    The market penetration of fuel and electrolysis cell energy systems in Europe requires the development of reliable assessment, testing and prediction of performance and durability of solid oxide cells and stacks (SOC). To advance in this field the EU-project “SOCTESQA” was launched in May 2014. Partners from different countries in Europe and one external party from Singapore are working together to develop uniform and industry wide test procedures and protocols for SOC cell/stack assembly. In...

  17. Testing - Smart strategy for safety and mission quality

    Science.gov (United States)

    Rodney, George A.

    The paper is concerned with the need for a comprehensive test plan for the Space Station Freedom (SST) that would fully verify specification compliance and be based on an error budget. In particular, attention is given to some lessons learned from other NASA programs and the principal challenges for SSF testing, including phase C/D/E agreements, testing parameters, phase testing, and the human element. The importance of close teamwork between the NASA/Contractor systems engineers and assurance engineers is emphasized.

  18. Flaw detection of welded joints in NPP equipment assembly

    International Nuclear Information System (INIS)

    Kesler, N.A.; Polevik, V.A.; Orlov, N.S.

    1984-01-01

    State of the art and prospects of development of ultrasonic and radiography testing of welded joints for quality used in NPP equipment assembly are considered. Recommendations are given on reducing the labour content with the use of these methods. Specifications for the developed facilities intended for automation and mechanization of the described quality control methods are presented

  19. Test-system for the control and selection of tests applicable to a weldment and its documentation for assembling the Angra - 2 pipelines

    International Nuclear Information System (INIS)

    Carvalho Nunez, J.I. de; Spiegelberg, N.; Souza Rosa, M. de; Soares Filho, J.C.T.

    1988-01-01

    Due to quality assurance characteristics applicable to the construction of a Nuclear Power Plant, the welding inspection for the piping erection becomes a very well controlled and documented activity. By means of informatic support, a system was developed for the control and selection of testes applicable to a weldment according to the suitable specification. As a result, it is obtained: cost reduction during the project phase, expedition of modifications due to isometric revision, better control and follow-up of inspections activities and piping erection, and the guarantee of the correct interpretation for the applicable specification. (author) [pt

  20. Control of quality in the tests of systems of containment of vehicles. Intercomparison of the results of the tests

    International Nuclear Information System (INIS)

    Lopez Ramos, S.

    2009-01-01

    This article tries to offer information on how Central Laboratory of Structures and Materials are made the tests for Marca N of AENOR of the systems of containment of vehicles and its control of external quality. (Author) 15 refs

  1. Framework and indicator testing protocol for developing and piloting quality indicators for the UK quality and outcomes framework

    Directory of Open Access Journals (Sweden)

    Burke Martyn

    2011-08-01

    Full Text Available Abstract Background Quality measures should be subjected to a testing protocol before being used in practice using key attributes such as acceptability, feasibility and reliability, as well as identifying issues derived from actual implementation and unintended consequences. We describe the methodologies and results of an indicator testing protocol (ITP using data from proposed quality indicators for the United Kingdom Quality and Outcomes Framework (QOF. Methods The indicator testing protocol involved a multi-step and methodological process: 1 The RAND/UCLA Appropriateness Method, to test clarity and necessity, 2 data extraction from patients' medical records, to test technical feasibility and reliability, 3 diaries, to test workload, 4 cost-effectiveness modelling, and 5 semi-structured interviews, to test acceptability, implementation issues and unintended consequences. Testing was conducted in a sample of representative family practices in England. These methods were combined into an overall recommendation for each tested indicator. Results Using an indicator testing protocol as part of piloting was seen as a valuable way of testing potential indicators in 'real world' settings. Pilot 1 (October 2009-March 2010 involved thirteen indicators across six clinical domains and twelve indicators passed the indicator testing protocol. However, the indicator testing protocol identified a number of implementation issues and unintended consequences that can be rectified or removed prior to national roll out. A palliative care indicator is used as an exemplar of the value of piloting using a multiple attribute indicator testing protocol - while technically feasible and reliable, it was unacceptable to practice staff and raised concerns about potentially causing actual patient harm. Conclusions This indicator testing protocol is one example of a protocol that may be useful in assessing potential quality indicators when adapted to specific country health

  2. ASVCP quality assurance guidelines: external quality assessment and comparative testing for reference and in-clinic laboratories.

    Science.gov (United States)

    Camus, Melinda S; Flatland, Bente; Freeman, Kathleen P; Cruz Cardona, Janice A

    2015-12-01

    The purpose of this document is to educate providers of veterinary laboratory diagnostic testing in any setting about comparative testing. These guidelines will define, explain, and illustrate the importance of a multi-faceted laboratory quality management program which includes comparative testing. The guidelines will provide suggestions for implementation of such testing, including which samples should be tested, frequency of testing, and recommendations for result interpretation. Examples and a list of vendors and manufacturers supplying control materials and services to veterinary laboratories are also included. © 2015 American Society for Veterinary Clinical Pathology.

  3. Quality control for quantitative PCR based on amplification compatibility test

    Czech Academy of Sciences Publication Activity Database

    Tichopád, Aleš; Bar, T.; Pecen, Ladislav; Kitchen, R.R.; Kubista, Mikael; Pfaffl, M.W.

    2010-01-01

    Roč. 50, č. 4 (2010), s. 308-312 ISSN 1046-2023 R&D Projects: GA AV ČR IAA500520809; GA AV ČR IAA500970904 Institutional research plan: CEZ:AV0Z50520701 Keywords : Quantitative PCR * Quality control * Amplification efficiency Subject RIV: EB - Genetics ; Molecular Biology Impact factor: 4.527, year: 2010

  4. Test calculations of physical parameters of the TRX,BETTIS and MIT critical assemblies according to the TRIFON program

    International Nuclear Information System (INIS)

    Kochurov, B.P.

    1980-01-01

    Results of calculations of physical parameters characterizing the TRX, MIT and BETTIS critical assemblies obtained according to the program TRIFON are presented. The program TRIFON permits to calculate the space-energy neutron distribution in the multigroup approximation in a multizone cylindrical cell. Results of comparison of the TRX, BETTIS and MIT crytical assembly parameters with experimental data and calculational results according to the Monte Carlo method are presented as well. Deviations of the parameters are in the range of 1.5-2 of experimental errors. Data on the interference of uranium 238 levels in the resonant neutron absorption in the cell are given [ru

  5. Results of water corrosion in static cell tests representing multi-metal assemblies in the hydraulic circuits of Tore supra

    Energy Technology Data Exchange (ETDEWEB)

    Lipa, M. [CEA/DSM/DRFC Centre de Cadarache, 13 - Saint-Paul lez Durance (France); Blanchet, J.; Cellier, F. [Framatome, 71 - Saint Marcel (France). Centre Technique

    2007-07-01

    Following experiences obtained with steam generator tubes of nuclear power plants, a cooling water quality of AVT (all volatile treatment) has been defined based on demineralised water with adjustment of the pH value to about 9.0/7.0 (25 C/200 C) by addiction of ammoniac, and hydrazine in order to absorb oxygen dissolved in water. At that time, a simplified water corrosion test program has been performed using static (no circulation) test cell samples made of above mentioned TS metal combinations. All test cell samples, prepared and filled with AVT water, were performed at 280 C and 65 bars in an autoclave during 3000 hours. The test cell water temperature has been chosen to be sufficient above the TS component working temperature, in order to accelerate an eventual corrosion process. Generally all above mentioned metal combinations survived the test campaign without stress corrosion cracking, with the exception of the memory metal junction (creep in Cu) and the bellows made of St-St 316L and Inconel 625 while 316 Ti bellows survived. In contrary to the vacuum brazed Cu-LSTP to St-St samples, some of flame brazed Cu to St-St samples failed either in the braze joint or in the copper structure itself. For comparison, a spot weld of an inflated 316L panel sample, filled voluntary with a caustic solution of pH 11.5 (25 C), failed after 90 h of testing (intergranular cracking at the spot weld), while an identical sample containing AVT water of pH 9.0 (25 C) survived without damage. The results of these tests, performed during 1986 and 1997, have never been published and therefore are presented more in detail in this paper since corrosion in hydraulic circuits is also an issue of ITER. Up to day, the TS cooling water plant operates with an above mentioned water treatment and no water leaks have been detected on in-vessel components originating from water corrosion at high temperature and high pressure. (orig.)

  6. Results of water corrosion in static cell tests representing multi-metal assemblies in the hydraulic circuits of Tore supra

    International Nuclear Information System (INIS)

    Lipa, M.; Blanchet, J.; Cellier, F.

    2007-01-01

    Following experiences obtained with steam generator tubes of nuclear power plants, a cooling water quality of AVT (all volatile treatment) has been defined based on demineralised water with adjustment of the pH value to about 9.0/7.0 (25 C/200 C) by addiction of ammoniac, and hydrazine in order to absorb oxygen dissolved in water. At that time, a simplified water corrosion test program has been performed using static (no circulation) test cell samples made of above mentioned TS metal combinations. All test cell samples, prepared and filled with AVT water, were performed at 280 C and 65 bars in an autoclave during 3000 hours. The test cell water temperature has been chosen to be sufficient above the TS component working temperature, in order to accelerate an eventual corrosion process. Generally all above mentioned metal combinations survived the test campaign without stress corrosion cracking, with the exception of the memory metal junction (creep in Cu) and the bellows made of St-St 316L and Inconel 625 while 316 Ti bellows survived. In contrary to the vacuum brazed Cu-LSTP to St-St samples, some of flame brazed Cu to St-St samples failed either in the braze joint or in the copper structure itself. For comparison, a spot weld of an inflated 316L panel sample, filled voluntary with a caustic solution of pH 11.5 (25 C), failed after 90 h of testing (intergranular cracking at the spot weld), while an identical sample containing AVT water of pH 9.0 (25 C) survived without damage. The results of these tests, performed during 1986 and 1997, have never been published and therefore are presented more in detail in this paper since corrosion in hydraulic circuits is also an issue of ITER. Up to day, the TS cooling water plant operates with an above mentioned water treatment and no water leaks have been detected on in-vessel components originating from water corrosion at high temperature and high pressure. (orig.)

  7. Quality checking task force destructive testing of active waste forms

    International Nuclear Information System (INIS)

    James, J.M.; Smith, D.L.

    1987-03-01

    The implications of sampling and testing of full size active packages of intermediate level wastes are summarised in this report. Sampling operations are technically feasible but a major difficulty will be the disposal of secondary waste. A literature survey indicated that destructive testing of wasteforms is not carried out as a routine operation in Europe or the USA. (author)

  8. Evaluation of data from HEPA filter quality assurance testing stations

    International Nuclear Information System (INIS)

    Collins, J.T.; Bellamy, R.R.; Allen, J.R.

    1979-01-01

    In Revision 1 to Regulatory Guide 1.52, issued in July 1976, the NRC recommended that high efficiency particulate air (HEPA) filters for use in engineered safety features (ESF) atmosphere cleanup systems be visually inspected and dioctylphtalate (DOP) tested at either of two Department of Energy (DOE) operated QA Filter Testing Stations prior to their installation and use in commercial nuclear power plants. This practice was initiated because filter vendors were unable to consistently provide a HEPA filter that would meet the stringent requirements established by DOE and NRC and its predecessor the AEC. In 1977, the NRC staff undertook a program to revise Regulatory Guide 1.52 to reflect recently issued industry standards (e.g., ANSI N509 and N510) and current industry practices. Revision 2 to Regulatory Guide 1.52 was formally issued in March 1978. In conducting this review, the recommendation that HEPA filters, intended for use in ESF systems in commercial nuclear power plants, be routinely tested at the DOE-QA Filter Testing Stations was revaluated. As part of this evluation a detailed analysis of the filter test results recorded by the two QA Testing Stations during the period 1971 to 1977 was conducted. This paper summarizes the results of the analysis and explains the rationale for deleting the requirement that all HEPA filters intended for use in ESF systems be tested at the AQ Testing Station

  9. Field Measurements of Perceived Air Quality in the Test-Bed for Innovative Climate Conditioning Technologies

    DEFF Research Database (Denmark)

    Kolarik, Jakub; Toftum, Jørn; Kabrhel, Michal

    the potential influence of aforementioned technologies on the perceived air quality. Additionally, the effect of Demand Controlled Ventilation (DCV) on the perceived air quality was tested. Measurements comprised of the assessments of perceived air quality and objective measurements of operative temperature...

  10. GESCAL: Quality management automated system for a calibration and test laboratory

    International Nuclear Information System (INIS)

    Manzano de Armas, J.; Valdes Ramos, M.; Morales Monzon, J.A.

    1998-01-01

    GESCAL is a software created to automate all elements composing the quality system in a calibration and test laboratory. It also evaluates quality according to its objectives and policies. This integrated data system decreases considerably the amount of time devoted to manage quality. It is speedier in searching and evaluating information registers thus notably in reducing the workload for laboratory staff

  11. Gasoline-Engine Assembler (engine & turbine) 806.781; Internal-Combustion-Engine-Assembler (engine & turbine) 806.781; Outboard-Motor Assembler (engine & turbine) 806.781--Technical Report on Development of USTES Aptitude Test Battery.

    Science.gov (United States)

    Manpower Administration (DOL), Washington, DC. U.S. Training and Employment Service.

    The United States Training and Employment Service General Aptitude Test Battery (GATB), first published in 1947, has been included in a continuing program of research to validate the tests against success in many different occupations. The GATB consists of 12 tests which measure nine aptitudes: General Learning Ability; Verbal Aptitude; Numerical…

  12. Sandia National Laboratories, Tonopah Test Range Assembly Building 9B (Building 09-54): Photographs and Written Historical and Descriptive Data

    Energy Technology Data Exchange (ETDEWEB)

    Ullrich, Rebecca A. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Corporate Archives and History Program

    2017-08-01

    Assembly Building 9B (Building 09-54) is a contributing element to the Sandia National Laboratories (SNL) Tonopah Test Range (TTR) Historic District. The SNL TTR Historic District played a significant role in U.S. Cold War history in the areas of stockpile surveillance and non-nuclear field testing of nuclear weapons designs. The district covers approximately 179,200 acres and illustrates Cold War development testing of nuclear weapons components and systems. This report includes historical information, architectural information, sources of information, project information, maps, blueprints, and photographs.

  13. Quality Control, Testing, and Deployment Results in the NIF ICCS

    International Nuclear Information System (INIS)

    Woodruff, J P; Casavant, D; Cline, B D; Gorvad, M R

    2001-01-01

    The strategy used to develop the NIF Integrated Computer Control System (ICCS) calls for incremental cycles of construction and formal test to deliver a total of 1 million lines of code. Each incremental release takes four to six months to implement specific functionality and culminates when offline tests conducted in the ICCS Integration and Test Facility verify functional, performance, and interface requirements. Tests are then repeated on line to confirm integrated operation in dedicated laser laboratories or ultimately in the NIF. Test incidents along with other change requests are recorded and tracked to closure by the software change control board (SCCB). Annual independent audits advise management on software process improvements. Extensive experience has been gained by integrating controls in the prototype laser preamplifier laboratory. The control system installed in the preamplifier lab contains five of the ten planned supervisory subsystems and seven of sixteen planned front-end processors (FEPs). Beam alignment, timing, diagnosis and laser pulse amplification up to 20 joules was tested through an automated series of shots. Other laboratories have provided integrated testing of six additional FEPs. Process measurements including earned-value, product size, and defect densities provide software project controls and generate confidence that the control system will be successfully deployed

  14. Production and Testing of Kiln-cast Glass Components for an Interlocking, Dry-assembled Transparent Bridge

    NARCIS (Netherlands)

    Bristogianni, T.; Oikonomopoulou, F.; Veer, F.A.; Snijder, A.H.; Nijsse, R.

    A pedestrian glass bridge, located at the TU Delft campus site, is being designed by the TU Delft Glass & Transparency Lab. Specifically, the arch-formed bridge consists of cast glass, dry-assembled, interlocking components. To validate the shape of the components, glass mock-ups in 1:2 scale

  15. Test Report: Assembly and Structural Loading of Army Research Lab’s High Strength Low Alloy - Vanadium (HSLA - V) Bridge

    Science.gov (United States)

    2010-04-28

    34 to 1" drive adapter MHE ============ 15,000 lbs forklift 6,000 lbs. forklift 5,000 pallet truck Two 30,000 lbs. 6’x16’ caster wheeled carts...Suggested modifications to reduce assembly time* ================================================== Use powered torque multipliers to torque bolts

  16. Is reverberation time adequate for testing the acoustical quality of unroofed auditoriums?

    DEFF Research Database (Denmark)

    Paini, Dario; Gade, Anders Christian; Rindel, Jens Holger

    2006-01-01

    30) and other acoustical parameters normally used to test the acoustical quality of closed auditoria, such as concert halls, theatres, opera houses, are suitable and sufficient for testing the acoustical quality of open performance spaces. Simulations as well as measurements were carried out to study...

  17. Fuel Assembly Damping Summary

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kanghee; Kang, Heungseok; Oh, Dongseok; Yoon, Kyungho; Kim, Hyungkyu; Kim, Jaeyong [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2013-10-15

    This paper summary the fuel assembly damping data in air/in still water/under flow, released from foreign fuel vendors, compared our data with the published data. Some technical issues in fuel assembly damping measurement testing are also briefly discussed. Understanding of each fuel assembly damping mechanisms according to the surrounding medium and flow velocity can support the fuel design improvement in fuel assembly dynamics and structural integrity aspect. Because the upgraded requirements of the newly-developed advanced reactor system will demands to minimize fuel design margin in integrity evaluation, reduction in conservatism of fuel assembly damping can contribute to alleviate the fuel design margin for sure. Damping is an energy dissipation mechanism in a vibrating mechanical structure and prevents a resonant structure from having infinite vibration amplitudes. The sources of fuel assembly damping are various from support friction to flow contribution, and it can be increased by the viscosity or drag of surrounding fluid medium or the average velocity of water flowing. Fuel licensing requires fuel design evaluation in transient or accidental condition. Dynamic response analysis of fuel assembly is to show fuel integrity and requires information on assembly-wise damping in dry condition and under wet or water flowing condition. However, damping measurement test for the full-scale fuel assembly prototype is not easy to carry out because of the scale (fuel prototype, test facility), unsteadiness of test data (scattering, random sampling and processing), instrumentation under water flowing (water-proof response measurement), and noise. LWR fuel technology division in KAERI is preparing the infra structure for damping measurement test of full-scale fuel assembly, to support fuel industries and related research activities. Here is a preliminary summary of fuel assembly damping, published in the literature. Some technical issues in fuel assembly damping

  18. Quality assurance of HIV counselling and testing for the prevention ...

    African Journals Online (AJOL)

    child transmission of HIV in Rivers State, Nigeria. ... Similarly, other resources for counselling such as television and video sets, posters and banners were in short supply. Important issues in post-test counselling such as information about ...

  19. Modern instrumentation for radiation introscopic testing of welding quality

    International Nuclear Information System (INIS)

    Sosnin, F.R.

    1985-01-01

    Modern instrumenlation used for radiation introscopy of welded joints is discussed. the absolute (relative) sensitivity of radiation testing, resolution range, efficiency are considered as basic parameters of introscopes. The characteristics of fluoroscopes, radiation-television installations with the external scintillator and radiative image converter as well as with X-ray vidicons are given. The characterisitcs of radiation introscopes with manipulators to move objects being tested are analysed as well as digitized radiation introscopes

  20. Commissioning of the STAR test section for experimental simulation of loss of coolant accident using the EC-208 instrumented fuel assembly of the IEA-R1 reactor

    Energy Technology Data Exchange (ETDEWEB)

    Maprelian, Eduardo; Torres, Walmir M.; Prado, Adelk C.; Umbehaun, Pedro E.; Franca, Renato L.; Santos, Samuel C.; Macedo, Luiz A.; Sabundjian, Gaiane, E-mail: emaprel@ipen.br, E-mail: wmtorres@ipen.br, E-mail: acprado@ipen.br, E-mail: umbehaun@ipen.br, E-mail: rlfranca@ipen.br, E-mail: samuelcs@ipen.br, E-mail: lamacedo@ipen.br, E-mail: gdjian@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SO (Brazil)

    2015-07-01

    The three basic safety functions of Research Reactors (RR) are the safe shutdown of the reactor, the proper cooling of the decay heat of the fuel elements and the confinement of radioactive materials. Compared to Nuclear Power Reactors, RR power release is small, yet its three safety functions must be met to ensure the integrity of the reactor. During a loss of coolant accident (LOCA) in pool type RR, partial or complete loss of pool water may occur, with consequent partial or complete uncovering of the fuel assemblies. In such an accident, the decay heat removal safety function must not be compromised. The Test Section for Experimental Simulation of Loss of Coolant Accident (STAR) is in commissioning phase. This test section will provide experimental data on partial and total uncovering of the EC-208 instrumented fuel assembly (IFA) irradiated in the IEA-R1. Experimental results will be useful in validation of computer codes for RR safety analysis, particularly on heat removal efficiency aspects (safety function) in accident conditions. STAR comprises a base on which is installed the IFA, the cylindrical stainless steel hull, the compressed air system for the test section emptying and refilling, and the instrumentation for temperature and level measurements. The commissioning tests or pre-operational check, consist of several preliminary tests to verify experimental procedures, the difficulties during assembling of STAR in the pool, the difficulties in control the emptying and refilling velocities, as well as, the repeatability capacity, tests of equipment, valves and systems and tests of instrumentation and data acquisition system. Safety, accuracy and easiness of operation will be checked. (author)

  1. Qualification of quality testing personnel, in particular the training offered

    International Nuclear Information System (INIS)

    Knoedler, D.

    1980-01-01

    Personnel qualification is one of the most important tasks of quality assurance. The qualification is reached by professional education, by experience made on the job and by additional external and company-internal training. A determination of qualification requirements should cover only the general principles. Especially this should be considered specifying the requirements for theoretical knowledge and for examinations since the factor of relevant experience is difficult to be estimated by third parties. Equal principles apply for the personnel of the manufacturer, of the main contractor, of the utility and of the auhtorized inspectors' organizations. The detailed guidelines should be part of the internal QA-systems of the organizations involved. (orig.) [de

  2. Investigation of grid performance using simple image quality tests

    Directory of Open Access Journals (Sweden)

    Dogan Bor

    2016-01-01

    Full Text Available Antiscatter grids improve the X-ray image contrast at a cost of patient radiation doses. The choice of appropriate grid or its removal requires a good knowledge of grid characteristics, especially for pediatric digital imaging. The aim of this work is to understand the relation between grid performance parameters and some numerical image quality metrics for digital radiological examinations. The grid parameters such as bucky factor (BF, selectivity (Σ, Contrast improvement factor (CIF, and signal-to-noise improvement factor (SIF were determined following the measurements of primary, scatter, and total radiations with a digital fluoroscopic system for the thicknesses of 5, 10, 15, 20, and 25 cm polymethyl methacrylate blocks at the tube voltages of 70, 90, and 120 kVp. Image contrast for low- and high-contrast objects and high-contrast spatial resolution were measured with simple phantoms using the same scatter thicknesses and tube voltages. BF and SIF values were also calculated from the images obtained with and without grids. The correlation coefficients between BF values obtained using two approaches (grid parameters and image quality metrics were in good agreement. Proposed approach provides a quick and practical way of estimating grid performance for different digital fluoroscopic examinations.

  3. Quality control/quality assurance testing for joint density and segregation of asphalt mixtures.

    Science.gov (United States)

    2013-04-01

    Longitudinal joint quality control/assurance is essential to the successful performance of asphalt pavements and it has received considerable amount of attention in recent years. The purpose of the study is to evaluate the level of compaction at the ...

  4. Quality Assurance Tests for Modern Optical Imaging Systems

    Science.gov (United States)

    Cole, R.W.; Stack, R.F.

    2010-01-01

    r10-1 Modern light microscopes are highly evolved opto-electronic-mechanical devices, most costing in the 100′s of thousands of dollars.The days of simply be being able to ascertain instrument performance by looking through the eye pieces at a specimen are gone.However, users as well as granting agencies need to be confident that data collected will be uniform and quantifiable both over time on the same instrument andfrom instrument to instrument.We have conducted the first stage of a world-wide research study on instrument performance utilizing three image-based tests.The goal of this study was not to compare the performance of different brands of instruments, nor to ascertain which brand had better performance in a given area.Simply, the aims of the study were: to ascertain the current state of light microscopes through simple and efficient, yet robust tests and to develop relative standards that will assist core managers and/or users in maintaining their instruments in optimal operating conditions. In an ideal world, a LASER would not fluctuate, illumination would be completely uniform and all colors would perfectly align.The tests selected were: long and short term stability tests of illumination sources, uniformity of field illumination, and co-localization across various wavelengths. There were instances where data from a single microscope was within range for some tests but not for all.There were other instances where single microscopes meet all or conversely none of the expected performance levels.From this data it is obvious that all three tests need to be performed on a regular basis to assure high fidelity data.

  5. DOE standard: Filter test facility quality program plan

    International Nuclear Information System (INIS)

    1999-02-01

    This standard was developed primarily for application in US Department of Energy programs. It contains specific direction for HEPA filter testing performed at a DOE-accepted HEPA Filter Test Facility (FTF). Beneficial comments (recommendations, additions, deletions) and any pertinent data that may improve this document should be sent to the Office of Nuclear Safety Policy and Standards (EH-31), US Department of Energy, Washington, DC 20585, by letter or by using the self-addressed Document Improvement Proposal form (DOE F 1300.3) appearing at the end of this document

  6. Results of water corrosion in static cell tests representing multi-metal assemblies in the hydraulic circuits of Tore Supra

    Energy Technology Data Exchange (ETDEWEB)

    Lipa, M.; Blanchet, J. [Association Euratom-CEA Cadarache, 13 - Saint-Paul-lez-Durance (France). Dept. de Recherches sur la Fusion Controlee; Cellier, F. [Framatome, Centre Technique, 71 - Saint Marcel (France)

    2007-07-01

    Full text of publication follows: Tore supra (TS) has used from the beginning of operation in 1989 actively cooled plasma facing components. Since the operation and baking temperature of all in vessel components has been defined to be up to 230 deg. C at 40 bars, a special water chemistry of the cooling water plant was suggested in order to avoid eventual water leaks due to corrosion (general corrosion, galvanic corrosion, stress corrosion, etc.) at relative high temperatures and pressures in tubes, pipes, bellows, water boxes, coils, etc. From the beginning of TS operation, in vessel components (e.g. wall protection panels, limiters, ergodic divertor coils, neutralisers and diagnostics) represented a unique combination of metals in the hydraulic circuit mainly such as stainless steel, Inconel, CuCrZr, Nickel and Copper. These different materials were joined together by welding (St to St, Inconel to Inconel, CuCrZr to CuCrZr and CuCrZr to St-St via a Ni sleeve adapter), brazing (St-St to Cu and Cu-LSTP), friction (CuCrZr and Cu to St-St), explosion (CuCrZr to St-St) and memory metal junction (Cryo-fit to Cu - only test sample). Following experiences obtained with steam generator tubes of nuclear power plants, a cooling water quality of AVT (all volatile treatment) has been defined based on demineralized water with adjustment of the pH value to about 9.0/ 7.0 (25 deg. C/ 200 deg. C) by addiction of ammoniac, and hydrazine in order to absorb oxygen dissolved in water. At that time, a simplified water corrosion test program has been performed using static (no circulation) test cell samples made of above mentioned TS metal combinations. All test cell samples, prepared and filled with AVT water, were performed at 280 deg. C and 65 bars in an autoclave during 3000 hours. The test cell water temperature has been chosen to be sufficient above the TS component working temperature, in order to accelerate an eventual corrosion process. Generally all above mentioned metal

  7. Results of water corrosion in static cell tests representing multi-metal assemblies in the hydraulic circuits of Tore Supra

    International Nuclear Information System (INIS)

    Lipa, M.; Blanchet, J.

    2007-01-01

    Full text of publication follows: Tore supra (TS) has used from the beginning of operation in 1989 actively cooled plasma facing components. Since the operation and baking temperature of all in vessel components has been defined to be up to 230 deg. C at 40 bars, a special water chemistry of the cooling water plant was suggested in order to avoid eventual water leaks due to corrosion (general corrosion, galvanic corrosion, stress corrosion, etc.) at relative high temperatures and pressures in tubes, pipes, bellows, water boxes, coils, etc. From the beginning of TS operation, in vessel components (e.g. wall protection panels, limiters, ergodic divertor coils, neutralisers and diagnostics) represented a unique combination of metals in the hydraulic circuit mainly such as stainless steel, Inconel, CuCrZr, Nickel and Copper. These different materials were joined together by welding (St to St, Inconel to Inconel, CuCrZr to CuCrZr and CuCrZr to St-St via a Ni sleeve adapter), brazing (St-St to Cu and Cu-LSTP), friction (CuCrZr and Cu to St-St), explosion (CuCrZr to St-St) and memory metal junction (Cryo-fit to Cu - only test sample). Following experiences obtained with steam generator tubes of nuclear power plants, a cooling water quality of AVT (all volatile treatment) has been defined based on demineralized water with adjustment of the pH value to about 9.0/ 7.0 (25 deg. C/ 200 deg. C) by addiction of ammoniac, and hydrazine in order to absorb oxygen dissolved in water. At that time, a simplified water corrosion test program has been performed using static (no circulation) test cell samples made of above mentioned TS metal combinations. All test cell samples, prepared and filled with AVT water, were performed at 280 deg. C and 65 bars in an autoclave during 3000 hours. The test cell water temperature has been chosen to be sufficient above the TS component working temperature, in order to accelerate an eventual corrosion process. Generally all above mentioned metal

  8. Evaluation of seed vigor tests for determinig alfalfa seed quality

    Directory of Open Access Journals (Sweden)

    hamidreza tavakoli kakhki

    2009-06-01

    Full Text Available In order to determine the best seed vigor test in laboratory which may provide high correlation between alfalfa seedling stablishment in the field, two experiment were conducted in field as well as in laboratory. Four alfalfa cultivars Bami, Ghareyonjeh, Hamadani and Yazdi were used. Different seed vigor tests including standard germination, germination in low tempretaure (5c , germination rate, osmotic stress, accelerated ageing and electrical conductivity tests were laid out in a randomized completely design (RCD with four replications in laboratory experiment‌. The second experiment was carried out in a randomized completely block design (RCBD and each treatment replicated four times‌. Results revealed significant differences (p≤ 0.01 among different cultivars for establishment percentage and rate. Results also showed that there were significant correlations between electrical conductivity test and establishment percentage (r= -0.65 , p ≤ 0.01 as well as establishment rate (r= -0.80 , p ≤ 0.01. Correlation coefficients for rate and emergence percentage were significant and positive (r= 0.91, p ≤ 0.01 . Stepwise method disclosed that the regression model (y=165.23 – 0.15 x r2=0.64 , (p ≤ 0.01 for predicting rate of emergence could be recommended. In this model x (dependent variable is value of electrical conductivity and y (independent variable is rate of emergence.

  9. Quality of Liver and Kidney Function Tests among Public Medical ...

    African Journals Online (AJOL)

    The aim of this study is to assess the accuracy and precision of clinical chemistry laboratories in western region of Amhara national regional state of Ethiopia in testing liver and kidney functions. Methods: Eight laboratories in hospitals and a Regional Health Research Laboratory Center participated in this study from ...

  10. Bacteriophage Assembly

    Directory of Open Access Journals (Sweden)

    Anastasia A. Aksyuk

    2011-02-01

    Full Text Available Bacteriophages have been a model system to study assembly processes for over half a century. Formation of infectious phage particles involves specific protein-protein and protein-nucleic acid interactions, as well as large conformational changes of assembly precursors. The sequence and molecular mechanisms of phage assembly have been elucidated by a variety of methods. Differences and similarities of assembly processes in several different groups of bacteriophages are discussed in this review. The general principles of phage assembly are applicable to many macromolecular complexes.

  11. Fuel assemblies

    International Nuclear Information System (INIS)

    Nakatsuka, Masafumi.

    1979-01-01

    Purpose: To prevent scattering of gaseous fission products released from fuel assemblies stored in an fbr type reactor. Constitution; A cap provided with means capable of storing gas is adapted to amount to the assembly handling head, for example, by way of threading in a storage rack of spent fuel assemblies consisting of a bottom plate, a top plate and an assembly support mechanism. By previously eliminating the gas inside of the assembly and the cap in the storage rack, gaseous fission products upon loading, if released from fuel rods during storage, are stored in the cap and do not scatter in the storage rack. (Horiuchi, T.)

  12. Sequence assembly

    DEFF Research Database (Denmark)

    Scheibye-Alsing, Karsten; Hoffmann, S.; Frankel, Annett Maria

    2009-01-01

    Despite the rapidly increasing number of sequenced and re-sequenced genomes, many issues regarding the computational assembly of large-scale sequencing data have remain unresolved. Computational assembly is crucial in large genome projects as well for the evolving high-throughput technologies and...... in genomic DNA, highly expressed genes and alternative transcripts in EST sequences. We summarize existing comparisons of different assemblers and provide a detailed descriptions and directions for download of assembly programs at: http://genome.ku.dk/resources/assembly/methods.html....

  13. Assessment of the quality of test results from selected civil engineering material testing laboratories in Tanzania

    CSIR Research Space (South Africa)

    Mbawala, SJ

    2017-12-01

    Full Text Available Civil and geotechnical engineering material testing laboratories are expected to produce accurate and reliable test results. However, the ability of laboratories to produce accurate and reliable test results depends on many factors, among others...

  14. Ventilation System Effectiveness and Tested Indoor Air Quality Impacts

    Energy Technology Data Exchange (ETDEWEB)

    Rudd, Armin [National Renewable Energy Lab. (NREL), Golden, CO (United States); Bergey, Daniel [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2014-02-01

    Ventilation system effectiveness testing was conducted at two unoccupied, single-family, detached lab homes at the University of Texas - Tyler. Five ventilation system tests were conducted with various whole-building ventilation systems. Multizone fan pressurization testing characterized building and zone enclosure leakage. PFT testing showed multizone air change rates and interzonal airflow. Cumulative particle counts for six particle sizes, and formaldehyde and other Top 20 VOC concentrations were measured in multiple zones. The testing showed that single-point exhaust ventilation was inferior as a whole-house ventilation strategy. It was inferior because the source of outside air was not direct from outside, the ventilation air was not distributed, and no provision existed for air filtration. Indoor air recirculation by a central air distribution system can help improve the exhaust ventilation system by way of air mixing and filtration. In contrast, the supply and balanced ventilation systems showed that there is a significant benefit to drawing outside air from a known outside location, and filtering and distributing that air. Compared to the Exhaust systems, the CFIS and ERV systems showed better ventilation air distribution and lower concentrations of particulates, formaldehyde and other VOCs. System improvement percentages were estimated based on four System Factor Categories: Balance, Distribution, Outside Air Source, and Recirculation Filtration. Recommended System Factors could be applied to reduce ventilation fan airflow rates relative to ASHRAE Standard 62.2 to save energy and reduce moisture control risk in humid climates. HVAC energy savings were predicted to be 8-10%, or $50-$75/year.

  15. Ventilation System Effectiveness and Tested Indoor Air Quality Impacts

    Energy Technology Data Exchange (ETDEWEB)

    Rudd, Armin [Building Science Corporation, Somerville, MA (United States); Bergey, Daniel [Building Science Corporation, Somerville, MA (United States)

    2014-02-01

    In this project, Building America research team Building Science Corporation tested the effectiveness of ventilation systems at two unoccupied, single-family, detached lab homes at the University of Texas - Tyler. Five ventilation system tests were conducted with various whole-building ventilation systems. Multizone fan pressurization testing characterized building and zone enclosure leakage. PFT testing showed multizone air change rates and interzonal airflow. Cumulative particle counts for six particle sizes, and formaldehyde and other Top 20 VOC concentrations were measured in multiple zones. The testing showed that single-point exhaust ventilation was inferior as a whole-house ventilation strategy. This was because the source of outside air was not direct from outside, the ventilation air was not distributed, and no provision existed for air filtration. Indoor air recirculation by a central air distribution system can help improve the exhaust ventilation system by way of air mixing and filtration. In contrast, the supply and balanced ventilation systems showed that there is a significant benefit to drawing outside air from a known outside location, and filtering and distributing that air. Compared to the exhaust systems, the CFIS and ERV systems showed better ventilation air distribution and lower concentrations of particulates, formaldehyde and other VOCs. System improvement percentages were estimated based on four system factor categories: balance, distribution, outside air source, and recirculation filtration. Recommended system factors could be applied to reduce ventilation fan airflow rates relative to ASHRAE Standard 62.2 to save energy and reduce moisture control risk in humid climates. HVAC energy savings were predicted to be 8-10%, or $50-$75/year.

  16. Underground Test Area Quality Assurance Project Plan Nevada National Security Site, Nevada, Revision 0

    Energy Technology Data Exchange (ETDEWEB)

    Irene Farnham

    2011-05-01

    This Quality Assurance Project Plan (QAPP) provides the overall quality assurance (QA) program requirements and general quality practices to be applied to the U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Site Office (NNSA/NSO) Underground Test Area (UGTA) Sub-Project (hereafter the Sub-Project) activities. The requirements in this QAPP are consistent with DOE Order 414.1C, Quality Assurance (DOE, 2005); U.S. Environmental Protection Agency (EPA) Guidance for Quality Assurance Project Plans for Modeling (EPA, 2002); and EPA Guidance on the Development, Evaluation, and Application of Environmental Models (EPA, 2009). The QAPP Revision 0 supersedes DOE--341, Underground Test Area Quality Assurance Project Plan, Nevada Test Site, Nevada, Revision 4.

  17. Testing Requirements to Manage Data Exchange Specifications in Enterprise Integration - A Schema Design Quality Focus.

    Energy Technology Data Exchange (ETDEWEB)

    Kulvatunyou, Boonserm [ORNL; Ivezic, Nenad [ORNL; Buhwan, Jeong [POSTECH University, South Korea

    2004-07-01

    In this paper, we describe the requirements to test W3C XML Schema usage when defining message schemas for data exchange in any large and evolving enterprise integration project. We then decompose the XML Schema testing into four (4) aspects including the message schema conformance to the XML Schema specification grammar, the message schema conformance to the XML Schema specification semantics, the message schema conformance to design quality testing, and canonical semantics testing of the message schema. We describe these four testing aspects in some detail and point to other related efforts. We further focus to provide some technical details for the message schema design quality testing. As a future work, we describe the requirements for canonical semantics testing and potential solution approaches. Finally, we describe an implementation architecture for the message schema design quality testing.

  18. Quality tests for SM1 MicroMegas detector module

    CERN Document Server

    Del Gaudio, M

    2016-01-01

    The Phase-I ATLAS upgrade (2018) aims to improve the detector performance at high luminosity (2 × 10$^{34}$ cm$^{−2}s$^{−1}$). In particular, the upgrade of the muon spectrometer focuses on the Small Wheels (SW) in the end-cap region, which cover 1.3 < |η| < 2.7. The SW will be replaced by the New Small Wheels (NSW), which is a set of precision tracking and trigger detectors able to work at high rates with excellent real-time spatial and time resolution. Each NSW will be constituted by multiplet of planar gaseous detectors, with trapezoidal shape: smallstrip Thin Gap Chamber (sTGC) and Micro-MEsh Gaseous Structure (MM). This paper describes some of the quality controls that the MM detectors must comply: planarity, thickness and gas tightness.

  19. Looking at prescription quality in Ayurveda: Developing, validating and pilot testing a prescription quality index for Ayurveda.

    Science.gov (United States)

    Rastogi, Sanjeev

    2017-11-06

    Prescription quality can be a direct predictor of the net outcome of a health care delivery effort. Quality of prescription may be considered as a cumulative matrix of multiple components of a prescription on the basis of their relative importance. Prescription quality index is a recognized tool in clinical medicine for multiple purposes including the prediction of health care intervention outcome. Considering the importance of prescription quality among every system of medicine, an attempt was made to design a prescription quality index for Ayurveda. The Prescription Quality Index for Ayurveda was designed through item selection following a thorough literature search and was validated through multiple peer group discussions. Final draft of index containing 38 individual items carrying different scores as per their importance in the prescription was subjected to a pilot test upon 1576 indoor prescriptions generated in 2015 at State Ayurvedic College Hospital, Lucknow. The study revealed large information gaps in the components of the prescription where it was supposed to be noted by the prescribers. These gaps in the Ayurvedic prescriptions were most significant in the areas pertaining to Ayurvedic fundamentals of clinical examination, disease diagnosis and Ayurvedic drug intake methods. Prescription Quality Index for Ayurveda was found useful in underlining the gaps between the ideal and generated prescriptions. This can be utilized as a useful tool to evaluate the quality of Ayurvedic prescriptions by seeing their adherence to the standard prescription template. Copyright © 2017 Transdisciplinary University, Bangalore and World Ayurveda Foundation. Published by Elsevier B.V. All rights reserved.

  20. Identification of the Quality Spot Welding used Non Destructive Test-Ultrasonic Testing: (Effect of Welding Time)

    Science.gov (United States)

    Sifa, A.; Endramawan, T.; Badruzzaman

    2017-03-01

    Resistance Spot Welding (RSW) is frequently used as one way of welding is used in the manufacturing process, especially in the automotive industry [4][5][6][7]. Several parameters influence the process of welding points. To determine the quality of a welding job needs to be tested, either by damaging or testing without damage, in this study conducted experimental testing the quality of welding or identify quality of the nugget by using Non-Destructive Test (NDT) -Ultrasonic Testing (UT), in which the identification of the quality of the welding is done with parameter thickness of worksheet after welding using NDT-UT with use same material worksheet and have more thickness of worksheet, the thickness of the worksheet single plate 1mm, with the capability of propagation Ultrasonic Testing (UT) standard limited> 3 mm [1], welding process parameters such as the time difference between 1-10s and the welding current of 8 KV, visually Heat Affected Zone ( HAZ ) have different results due to the length of time of welding. UT uses a probe that is used with a frequency of 4 MHz, diameter 10 mm, range 100 and the couplant used is oil. Identification techniques using drop 6dB, with sound velocity 2267 m / s of Fe, with the result that the effect of the Welding time affect the size of the HAZ, identification with the lowest time 1s show results capable identified joined through NDT - UT.

  1. TPX assembly plan

    International Nuclear Information System (INIS)

    Knutson, D.

    1993-01-01

    The TPX machine will be assembled in the TFTR Test Cell at the Plasma Physics Laboratory, utilizing the existing TFTR machine foundation. Preparation of the area for assembly will begin after completion of the decontamination and decommissioning phase on TFTR and certification that the radiation levels remaining, if any, are consistent with the types of operations planned. Assembly operations begin with the arrival of the first components, and conclude, approximately 24 months later, with the successful completion of the integrated systems tests and the achievement of a first plasma

  2. Establishment of a radiotherapy service with a linear accelerator (photons): acceptance tests, dosimetry and quality control

    International Nuclear Information System (INIS)

    Berdaky, Mafalda Feliciano

    2000-01-01

    This work presents the operational part of the final process of the establishment of a radiotherapy service with a linear accelerator (6 MeV photon beams), including the acceptance tests, commissioning tests and the implementation of a quality control program through routine mechanical and radiation tests. All acceptance tests were satisfactory, showing results below the allowed limits of the manufacturer, the commissioning tests presented results within those of the international recommendations. The quality control program was performed during 34 months and showed an excellent stability of this accelerator. (author)

  3. Comparative analysis of quality control tests on computed tomography in accordance with national and international laws

    International Nuclear Information System (INIS)

    Ramos, Fernando S.; Vasconcelos, Rebeca S.; Goncalves, Marcel S.; Oliveira, Marcus V.L. de

    2014-01-01

    The objective of this study is to perform a comparative analysis between the Brazilian legislation and internationals protocols, with respect to the quality control tests for computerized tomography. We used 07 references, published from 1998-2012: the Protocolo Brasileiro - Portaria 453/98 SVS/MS and the Guia de Radiodiagnostico Medico da ANVISA; Quality Assurance Programme for Computed Tomography: Diagnostic and Therapy Applications of the IAEA; European Protocol - European Guidelines on Quality Criteria for Computed Tomography of the EUR No. 16262 EN; Radiation Protection No. 162 - Criteria for Acceptability of Medical Radiology, Nuclear Medicine and Radiotherapy of the European Commission; the Protocols of Control de Calidad en Radiodiagnostico IAEA / ARCAL XLIX; and the Protocolo Espanol de Control de Calidad en Radiodignostico. The comparative analysis of these legislations was based on aspects of tolerance / limit, frequency and objectives of the recommended tests. Were found 18 tests in the Brazilian legislation. The tests were grouped according to their nature (dosimetric tests / exposure and geometric tests and image quality tests). Among the evaluated protocols was identified divergence between tests contained in the documents and the criteria of assessment set out in this work. It is clear, moreover, that for certain documents are not observed tolerances, well-defined methodologies and even frequency of testing. We conclude that the current legislation in Brazil differs in certain respects from international protocols analyzed, although this has a great numbers of quality control tests. However, it is necessary that the Brazilian legislation takes into account technological advances presented to time

  4. Constancy tests and quality assurance of the activimeters used in a radiopharmaceutical production unit

    International Nuclear Information System (INIS)

    Gontijo, Rodrigo M.G.; Mamede, Marcelo; Ferreira, Andréa V.; Nascimento, Leonardo T.C.; Costa, Flávia M.; Silva, Juliana B.

    2017-01-01

    Activimeters (or dose calibrators) are essential instruments to verify activity of radiopharmaceutical after production and also before the dose administration in humans or animals for molecular imaging. The efficiency and safety measurements depend on, beside other factors, constancy tests and quality assurance. Thereby, the aim of this work was to perform constancy tests and quality assurance in the activimeters of the UPPR/CDTN, based on the CNEN-NN 3.05 Brazilian standard and the manufacturer's manual. Physical inspection, auto zero, background check, camera voltage, data check and constancy test were done. In addition, accuracy and precision tests were performed using a set of standard certified radioactive sources ( 57 Co, 133 Ba and 137 Cs), according to the CNEN NN 3.05 Brazilian standard. Linearity test was also performed to evaluate the response of the equipment in over the entire range of activities used in routine. The equipment are periodically submitted to the quality control tests and the results were compared. After performing the proposed tests it is possible to conclude that activimeters are in accordance with the requirements of the CNEN standard and manufacturer's manual. A quality control checklist was prepared to guide users and to record the results of quality assurance testing to monitor the equipment performance. This initiative is part of the quality assurance program implemented at UPPR. (author)

  5. Constancy tests and quality assurance of the activimeters used in a radiopharmaceutical production unit

    Energy Technology Data Exchange (ETDEWEB)

    Gontijo, Rodrigo M.G.; Mamede, Marcelo [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Ferreira, Andréa V.; Nascimento, Leonardo T.C.; Costa, Flávia M.; Silva, Juliana B., E-mail: rodrigo.gontijo@cdtn.br, E-mail: mamede.mm@gmail.com [Universidade Federal de Minas Gerais (IMA/FM/UFMG), Belo Horizonte, MG (Brazil). Departamento de Anatomia e Imagem

    2017-07-01

    Activimeters (or dose calibrators) are essential instruments to verify activity of radiopharmaceutical after production and also before the dose administration in humans or animals for molecular imaging. The efficiency and safety measurements depend on, beside other factors, constancy tests and quality assurance. Thereby, the aim of this work was to perform constancy tests and quality assurance in the activimeters of the UPPR/CDTN, based on the CNEN-NN 3.05 Brazilian standard and the manufacturer's manual. Physical inspection, auto zero, background check, camera voltage, data check and constancy test were done. In addition, accuracy and precision tests were performed using a set of standard certified radioactive sources ({sup 57}Co, {sup 133}Ba and {sup 137}Cs), according to the CNEN NN 3.05 Brazilian standard. Linearity test was also performed to evaluate the response of the equipment in over the entire range of activities used in routine. The equipment are periodically submitted to the quality control tests and the results were compared. After performing the proposed tests it is possible to conclude that activimeters are in accordance with the requirements of the CNEN standard and manufacturer's manual. A quality control checklist was prepared to guide users and to record the results of quality assurance testing to monitor the equipment performance. This initiative is part of the quality assurance program implemented at UPPR. (author)

  6. Quality evaluation tests for pervious concrete pavements’ placement

    Directory of Open Access Journals (Sweden)

    Milena Rangelov

    2017-05-01

    Full Text Available Pervious concrete pavements are gaining popularity for stormwater management. Therefore, there is an impending need for the development of quality control and acceptance specifications. In this study, the necessary initial steps are taken towards this goal. The procedures to conduct fresh and hardened density/porosity (φ and 28-day compressive strength (f′c were evaluated. The proper methodology for casting specimens in the field was identified by examining the agreement between the fresh (D and hardened density (ρ. The effect of cylindrical size, and curing methods as combinations of air and moist curing during the four-week period on f′c was studied.Both cylinder sizes demonstrated comparable values of hardened porosity (φ = 16 percent and hardened density (D = 2.11 kg/m3, as well as strong linear φ–D correlations (R2 range 0.60–0.90. The values of D agree well with those of the fresh density (two percent or less difference, which confirmed the suitability of the implemented casting and compaction procedure. Small cylinders presented higher 28-day f′c than large cylinders by 7.7 to 19 percent, depending on the curing category. The two-week air followed by two-week moist curing (2A2 M method yielded the highest 28-day f′c for both specimen sizes, however, longer periods of moist curing did not result in higher strengths. Cylinders from 1A3M, which were exposed to the longest moist curing, demonstrate the lowest f′c. Thermogravimetric analysis (TGA confirmed the trends seen in 28-day f′c and proved (that longer moist curing resulted in the loss of C–S–H and Ca(OH2. Keywords: Pervious concrete, Porosity, Density, Compressive strength, Curing

  7. The Influence of Anxiety and Quality of Interaction on Collaborative Test Performance

    Science.gov (United States)

    Pandey, Carol; Kapitanoff, Susan

    2011-01-01

    This research investigated the relationships among test performance, anxiety, and the quality of interaction during collaborative testing of college students. It also explored which students are most likely to benefit from collaborative testing. It was randomly determined whether a student would take each of six examinations alone or with a…

  8. Stress test performed on gas transport pipelines as a method for quality assurance

    International Nuclear Information System (INIS)

    Kuelzer, J.; Baessler, R.

    1991-01-01

    Modern pipeline construction increasingly uses the stress test as an integral component test while aiming at enhanced safety and availability. The application described by the article highlights the particular fact that expanded and non-expanded pipes of identical material quality will reveal a different behaviour in the stress test. (orig.) [de

  9. Immediate tasks in realization of 52-53 Sessions of United Nations Organization General Assembly resolution on Semipalatinsk nuclear test site

    International Nuclear Information System (INIS)

    Ibraev, S.

    2000-01-01

    The author points out, that ecological heritage of Semipalatinsk test site is not studied, scattered investigations does not give objective assessment about radiation situation in the region. Only operations of close down of wells on the base of inter-state agreement between Republic of Kazakhstan and the United States of America were carried out. There are following main rehabilitation measures on liquidation of nuclear tests consequences in the region: study, deactivation and re-cultivation of populated territories; study of radioactive contamination level in underground waters and definition radionuclides migration by biological chain for taking preventative measures. It is noted, that citizens of the region with gratitude took solution of 52-53 Sessions of United Nations Organization General Assembly 'On liquidation of nuclear tests consequences on Semipalatinsk nuclear test site

  10. Design, Assembly, Integration, and Testing of a Power Processing Unit for a Cylindrical Hall Thruster, the NORSAT-2 Flatsat, and the Vector Gravimeter for Asteroids Instrument Computer

    Science.gov (United States)

    Svatos, Adam Ladislav

    This thesis describes the author's contributions to three separate projects. The bus of the NORSAT-2 satellite was developed by the Space Flight Laboratory (SFL) for the Norwegian Space Centre (NSC) and Space Norway. The author's contributions to the mission were performing unit tests for the components of all the spacecraft subsystems as well as designing and assembling the flatsat from flight spares. Gedex's Vector Gravimeter for Asteroids (VEGA) is an accelerometer for spacecraft. The author's contributions to this payload were modifying the instrument computer board schematic, designing the printed circuit board, developing and applying test software, and performing thermal acceptance testing of two instrument computer boards. The SFL's cylindrical Hall effect thruster combines the cylindrical configuration for a Hall thruster and uses permanent magnets to achieve miniaturization and low power consumption, respectively. The author's contributions were to design, build, and test an engineering model power processing unit.

  11. Non-destructive testing of assemblies by welding, brazing or bonding, and material to use for this process

    International Nuclear Information System (INIS)

    Benoit, J.

    1983-01-01

    The process consists in doing a neutron photography of the pieces assembled with the aid of a joining material containing a neutrophage element, such as gadolinium, samarium, europium, boron, cadmium. The neutrophage element, e.g. gadolinium, is dispersed in the joining material with contents between 0,5 and 7,5% of weight. Its granulometry must be less than 1000 MESH. The incorporation of a neutrophage element in the joining material of metallic pieces by welding or brazing, allows to visualize, among others, the following defects: blistering, cracks, slag inclusions, undercuts, bad distribution of the successive passes [fr

  12. ENDF/B-VII.1 Neutron Cross Section Data Testing with Critical Assembly Benchmarks and Reactor Experiments

    Energy Technology Data Exchange (ETDEWEB)

    Kahler, A.C.; Herman, M.; Kahler,A.C.; MacFarlane,R.E.; Mosteller,R.D.; Kiedrowski,B.C.; Frankle,S.C.; Chadwick,M.B.; McKnight,R.D.; Lell,R.M.; Palmiotti,G.; Hiruta,H.; Herman,M.; Arcilla,R.; Mughabghab,S.F.; Sublet,J.C.; Trkov,A.; Trumbull,T.H.; Dunn,M.

    2011-12-01

    The ENDF/B-VII.1 library is the latest revision to the United States Evaluated Nuclear Data File (ENDF). The ENDF library is currently in its seventh generation, with ENDF/B-VII.0 being released in 2006. This revision expands upon that library, including the addition of new evaluated files (was 393 neutron files previously, now 423 including replacement of elemental vanadium and zinc evaluations with isotopic evaluations) and extension or updating of many existing neutron data files. Complete details are provided in the companion paper [M. B. Chadwick et al., 'ENDF/B-VII.1 Nuclear Data for Science and Technology: Cross Sections, Covariances, Fission Product Yields and Decay Data,' Nuclear Data Sheets, 112, 2887 (2011)]. This paper focuses on how accurately application libraries may be expected to perform in criticality calculations with these data. Continuous energy cross section libraries, suitable for use with the MCNP Monte Carlo transport code, have been generated and applied to a suite of nearly one thousand critical benchmark assemblies defined in the International Criticality Safety Benchmark Evaluation Project's International Handbook of Evaluated Criticality Safety Benchmark Experiments. This suite covers uranium and plutonium fuel systems in a variety of forms such as metallic, oxide or solution, and under a variety of spectral conditions, including unmoderated (i.e., bare), metal reflected and water or other light element reflected. Assembly eigenvalues that were accurately predicted with ENDF/B-VII.0 cross sections such as unmoderated and uranium reflected {sup 235}U and {sup 239}Pu assemblies, HEU solution systems and LEU oxide lattice systems that mimic commercial PWR configurations continue to be accurately calculated with ENDF/B-VII.1 cross sections, and deficiencies in predicted eigenvalues for assemblies containing selected materials, including titanium, manganese, cadmium and tungsten are greatly reduced. Improvements are also

  13. ENDF/B-VII.1 Neutron Cross Section Data Testing with Critical Assembly Benchmarks and Reactor Experiments

    Energy Technology Data Exchange (ETDEWEB)

    Kahler, A. [Los Alamos National Laboratory (LANL); Macfarlane, R E [Los Alamos National Laboratory (LANL); Mosteller, R D [Los Alamos National Laboratory (LANL); Kiedrowski, B C [Los Alamos National Laboratory (LANL); Frankle, S C [Los Alamos National Laboratory (LANL); Chadwick, M. B. [Los Alamos National Laboratory (LANL); Mcknight, R D [Argonne National Laboratory (ANL); Lell, R M [Argonne National Laboratory (ANL); Palmiotti, G [Idaho National Laboratory (INL); Hiruta, h [Idaho National Laboratory (INL); Herman, Micheal W [Brookhaven National Laboratory (BNL); Arcilla, r [Brookhaven National Laboratory (BNL); Mughabghab, S F [Brookhaven National Laboratory (BNL); Sublet, J C [Culham Science Center, Abington, UK; Trkov, A. [Jozef Stefan Institute, Slovenia; Trumbull, T H [Knolls Atomic Power Laboratory; Dunn, Michael E [ORNL

    2011-01-01

    The ENDF/B-VII.1 library is the latest revision to the United States' Evaluated Nuclear Data File (ENDF). The ENDF library is currently in its seventh generation, with ENDF/B-VII.0 being released in 2006. This revision expands upon that library, including the addition of new evaluated files (was 393 neutron files previously, now 423 including replacement of elemental vanadium and zinc evaluations with isotopic evaluations) and extension or updating of many existing neutron data files. Complete details are provided in the companion paper [1]. This paper focuses on how accurately application libraries may be expected to perform in criticality calculations with these data. Continuous energy cross section libraries, suitable for use with the MCNP Monte Carlo transport code, have been generated and applied to a suite of nearly one thousand critical benchmark assemblies defined in the International Criticality Safety Benchmark Evaluation Project's International Handbook of Evaluated Criticality Safety Benchmark Experiments. This suite covers uranium and plutonium fuel systems in a variety of forms such as metallic, oxide or solution, and under a variety of spectral conditions, including unmoderated (i.e., bare), metal reflected and water or other light element reflected. Assembly eigenvalues that were accurately predicted with ENDF/B-VII.0 cross sections such as unrnoderated and uranium reflected (235)U and (239)Pu assemblies, HEU solution systems and LEU oxide lattice systems that mimic commercial PWR configurations continue to be accurately calculated with ENDF/B-VII.1 cross sections, and deficiencies in predicted eigenvalues for assemblies containing selected materials, including titanium, manganese, cadmium and tungsten are greatly reduced. Improvements are also confirmed for selected actinide reaction rates such as (236)U; (238,242)Pu and (241,243)Am capture in fast systems. Other deficiencies, such as the overprediction of Pu solution system critical

  14. Study on the testing standards of quality assurance for CT image

    International Nuclear Information System (INIS)

    Liu Jingxin; Yang Haishan; Liu Gang; Wang Liyun

    2000-01-01

    Objective: To establish national testing standards of quality assurance for CT image. Methods: 104 sets of CT system were tested using quality assurance test phantoms and devices including American RMI 461A, RMI 463, MDH 1015 C with ION Chamber, Sweden UNF 9004 kvp meter. These CT were made from different manufacturers including out of date of CT and state-of-art spiral CT system. Thirteen kinds of standards on CT from different countries and 87 sets of technical specifications of CT were collected. The results of the test were compared using phantoms of RMI, Victoreen, Catphan on the same CT system (Siemens HQS). Results: Based on the test results of this study, with reference to the foreign standards and some of regulations in China, CT test items should include high contrast resolution, low contrast resolution, noise, uniformity, mean CT unit, dose slice thickness, localization light, positioning of patient support and gantry tilt. Standards including acceptance test, status test, and constancy test were made in specification. Among them, constancy test equals to IEC 122-2-6; items and results in acceptance test are stricter than in the status test; and low contrast resolution, uniformity, localization light accuracy and positioning of patient support in the acceptance test are even stricter than that in foreign standards. Conclusion: The testing standards of quality assurance for CT developed in this study shows practical and useful in China, which supplemented to the existing international standards

  15. Integral test of International Reactor Dosimetry and Fusion File with Li{sub 2}O assembly and DT neutron source at JAEA/FNS

    Energy Technology Data Exchange (ETDEWEB)

    Sato, Satoshi, E-mail: sato.satoshi92@jaea.go.jp [Japan Atomic Energy Agency, Tokai-mura, Naka-gun, Ibaraki-ken (Japan); Kwon, Saerom; Ohta, Masayuki [Japan Atomic Energy Agency, Tokai-mura, Naka-gun, Ibaraki-ken (Japan); Ochiai, Kentaro [Japan Atomic Energy Agency, Rokkasho-mura, Kamikita-gun, Aomori-ken (Japan); Konno, Chikara [Japan Atomic Energy Agency, Tokai-mura, Naka-gun, Ibaraki-ken (Japan)

    2016-11-01

    In order to validate a new library of dosimetry cross section data, International Reactor Dosimetry and Fusion File release 1.0 (IRDFF 1.0), not only for DT neutrons but also for neutrons with energy of less than 14 MeV, we perform an integral test with a Li{sub 2}O rectangular assembly of 60.7 cm in thickness and a DT neutron source at JAEA/FNS. We place a lot of activation foils at depths of 10.1 cm and 30.4 cm for measurements of dosimetry reaction rates in small space along the central axis in the assembly, measure decay gamma-rays from the activation foils with high-purity Ge detectors after the DT neutron irradiation by the foil activation technique, and deduce a variety of dosimetry reaction rates. We calculate the reaction rates by using a Monte Carlo code MCNP5-1.40 and the nuclear data library ENDF/B-VII.1 with the IRDFF-v.1.05 as the response functions for the dosimetry reactions. The calculation results generally show good agreements with the measured ones, and it can be confirmed that most of the data in IRDFF-v.1.05 are valid for the neutron field in the Li{sub 2}O assembly with the DT neutrons.

  16. Assessment Sleep Quality and its Relationship with Test Anxiety among High School Students in Qom- Iran

    Directory of Open Access Journals (Sweden)

    Saman barmeh ziyar

    2016-10-01

    Full Text Available Background Test anxiety is a special case of a general anxiety which is of particular importance in students, because students will be the future of the country and the society activists. On the other hand, sleep quality and sleep disorders, have correlation with ailments, poor performance, decreased quality of life and increase of associated costs; This study aimed to determine the quality of sleep and its relationship with test anxiety among students in Qom city, Iran. Materials and Methods This study was a cross-sectional study, which was performed among 250 students who were going to pass the exam preparation classes. In order to collect data Pittsburgh Sleep Quality Index (PSQI questionnaires and Test Anxiety Inventory (TAI questionnaire were used. Data were analyzed using SPSS-16 with descriptive statistics and statistical methods, independent t-test, ANOVA and Pearson correlation coefficient. Results In this study, 50% of participants were boys (n=125 and 50 percent were girls (n=125. 81.4% of subjects had poor sleep quality and 69.6% had average to high score for test anxiety. Based on the results of anxiety test and sleep quality index there was a significant correlation between anxiety and sleep quality with gender (P=0.003, r=0.447. Conclusion School children had poor sleep quality and high test anxiety, and due to their direct and significant correlation, attention to this category of students, especially for girls, is important. Therefore, anxiety and promoting sleep quality control programs are recommended in this group.

  17. Quality of education and memory test performance in older men: the New York University Paragraph Recall Test normative data.

    Science.gov (United States)

    Mathews, Melissa; Abner, Erin; Caban-Holt, Allison; Dennis, Brandon C; Kryscio, Richard; Schmitt, Frederick

    2013-09-01

    Memory evaluation is a key component in the accurate diagnosis of cognitive disorders.One memory procedure that has shown promise in discriminating disease-related cognitive decline from normal cognitive aging is the New York University Paragraph Recall Test; however, the effects of education have been unexamined as they pertain to one's literacy level. The current study provides normative data stratified by estimated quality of education as indexed by irregular word reading skill. Conventional norms were derived from a sample (N = 385) of cognitively intact elderly men who were initially recruited for participation in the PREADViSE clinical trial. A series of multiple linear regression models were constructed to assess the influence of demographic variables on mean NYU Paragraph Immediate and Delayed Recall scores. Test version, assessment site, and estimated quality of education were significant predictors of performance on the NYU Paragraph Recall Test. Findings indicate that estimated quality of education is a better predictor of memory performance than ethnicity and years of total education. Normative data stratified according to estimated quality of education are presented. The current study provides evidence and support for normativedata stratified by quality of education as opposed to years of education.

  18. Integrated corridor management initiative : demonstration phase evaluation, San Diego air quality test plan.

    Science.gov (United States)

    2012-08-01

    This report presents the test plan for conducting the Air Quality Analysis for the United States Department of Transportation (U.S. DOT) evaluation of the San Diego Integrated Corridor Management (ICM) Initiative Demonstration. The ICM projects being...

  19. Integrated corridor management initiative : demonstration phase evaluation, Dallas air quality test plan.

    Science.gov (United States)

    2012-08-01

    This report presents the test plan for conducting the Air Quality Analysis for the United States : Department of Transportation (U.S. DOT) evaluation of the Dallas U.S. 75 Integrated Corridor : Management (ICM) Initiative Demonstration. The ICM proje...

  20. Disrupting self-assembly and toxicity of amyloidogenic protein oligomers by "molecular tweezers" - from the test tube to animal models.

    Science.gov (United States)

    Attar, Aida; Bitan, Gal

    2014-01-01

    Despite decades of research, therapy for diseases caused by abnormal protein folding and aggregation (amyloidoses) is limited to treatment of symptoms and provides only temporary and moderate relief to sufferers. The failure in developing successful disease-modifying drugs for amyloidoses stems from the nature of the targets for such drugs - primarily oligomers of amyloidogenic proteins, which are distinct from traditional targets, such as enzymes or receptors. The oligomers are metastable, do not have well-defined structures, and exist in dynamically changing mixtures. Therefore, inhibiting the formation and toxicity of these oligomers likely will require out-of-the-box thinking and novel strategies. We review here the development of a strategy based on targeting the combination of hydrophobic and electrostatic interactions that are key to the assembly and toxicity of amyloidogenic proteins using lysine (K)-specific "molecular tweezers" (MTs). Our discussion includes a survey of the literature demonstrating the important role of K residues in the assembly and toxicity of amyloidogenic proteins and the development of a lead MT derivative called CLR01, from an inhibitor of protein aggregation in vitro to a drug candidate showing effective amelioration of disease symptoms in animal models of Alzheimer's and Parkinson's diseases.