WorldWideScience

Sample records for tess tandem experiment

  1. The TESS [Tandem Experiment Simulation Studies] computer code user's manual

    International Nuclear Information System (INIS)

    Procassini, R.J.

    1990-01-01

    TESS (Tandem Experiment Simulation Studies) is a one-dimensional, bounded particle-in-cell (PIC) simulation code designed to investigate the confinement and transport of plasma in a magnetic mirror device, including tandem mirror configurations. Mirror plasmas may be modeled in a system which includes an applied magnetic field and/or a self-consistent or applied electrostatic potential. The PIC code TESS is similar to the PIC code DIPSI (Direct Implicit Plasma Surface Interactions) which is designed to study plasma transport to and interaction with a solid surface. The codes TESS and DIPSI are direct descendants of the PIC code ES1 that was created by A. B. Langdon. This document provides the user with a brief description of the methods used in the code and a tutorial on the use of the code. 10 refs., 2 tabs

  2. VVER-440 training simulators upgrades - Experience of CORYS T.E.S.S

    International Nuclear Information System (INIS)

    Bartak, J.; Fallon, B.

    2006-01-01

    The paper presents recent projects of upgrading screen operated simulators of VVER-440 nuclear power plants to full scale replica simulators, implemented by CORYS TESS. Control room replica full scope simulators were built for the Bohunice NPP in Slovakia and the Novovoronezh NPP in Russia. The scope of simulation was extended to reflect the current status of the units, which have undergone significant modernization programs over the last few years. The paper describes the software and hardware adaptations and evolutions of the existing simulators, the implementation in the simulator of modern supervision systems as well as of systems and equipment designed in the seventies and still used on the reference units. The training benefits of parallel use of control room replica and screen-operated simulators in the training process are discussed. (author)

  3. TESS Objects of Interest

    Science.gov (United States)

    Guerrero, Natalia; Glidden, Ana; Fausnaugh, Michael; TESS Team

    2018-01-01

    We describe the search for TESS Objects of Interest (TOIs), led by the MIT branch of the TESS Science Office (TSO). TSO has developed a tool called TESS Exoplanet Vetter (TEV) to facilitate this process. Individuals independently examine data validation products for each target and assign a category to the object: planet candidate, eclipsing binary, other astrophysical, stellar variability, or instrument noise/systematic. TEV assigns a preliminary follow-up priority designation to each object and allows for modification when final dispositions are decided on in a group setting. When all targets are vetted, TEV exports a catalogue of TOIs which is delivered to the TESS Follow-Up Observing Program (TFOP), working with ExoFOP-TESS, and made publicly available on the official TESS website and the Mikulski Archive for Space Telescopes (MAST).

  4. Current results of the tandem mirror experiment

    International Nuclear Information System (INIS)

    Drake, R.P.

    1980-01-01

    The basic operating characteristics of the Tandem Mirror Experiment, (TMX) at the Lawrence Livermore Laboratory in the USA have been established. Tandem-mirror plasmas have been produced using neutral-beam-fueled end plugs and a gas-fueled center cell. An axial potential well between the end plugs has been measured. There is direct evidence that this potential well enhances the axial confinement of the center-cell ions. The observed densities and loss currents are consistent with preliminary studies of the particle sources and losses near the magnetic axis. The observed confinement is consistent with theory when plasma fluctuations are low. When the requirement of drift-cyclotron loss-cone mode stability is violated, the plasma fluctuations degrade the center-cell confinement

  5. Triple echo steady-state (TESS) relaxometry.

    Science.gov (United States)

    Heule, Rahel; Ganter, Carl; Bieri, Oliver

    2014-01-01

    Rapid imaging techniques have attracted increased interest for relaxometry, but none are perfect: they are prone to static (B0 ) and transmit (B1 ) field heterogeneities, and commonly biased by T2 /T1 . The purpose of this study is the development of a rapid T1 and T2 relaxometry method that is completely (T2 ) or partly (T1 ) bias-free. A new method is introduced to simultaneously quantify T1 and T2 within one single scan based on a triple echo steady-state (TESS) approach in combination with an iterative golden section search. TESS relaxometry is optimized and evaluated from simulations, in vitro studies, and in vivo experiments. It is found that relaxometry with TESS is not biased by T2 /T1 , insensitive to B0 heterogeneities, and, surprisingly, that TESS-T2 is not affected by B1 field errors. Consequently, excellent correspondence between TESS and reference spin echo data is observed for T2 in vitro at 1.5 T and in vivo at 3 T. TESS offers rapid T1 and T2 quantification within one single scan, and in particular B1 -insensitive T2 estimation. As a result, the new proposed method is of high interest for fast and reliable high-resolution T2 mapping, especially of the musculoskeletal system at high to ultra-high fields. Copyright © 2013 Wiley Periodicals, Inc.

  6. TMX-U [Tandem Mirror Experiment-Upgrade] tandem-mirror thermal-barrier experiments

    International Nuclear Information System (INIS)

    Simonen, T.C.; Allen, S.L.; Baldwin, D.E.

    1986-01-01

    Thermal-barrier experiments have been carried out in the Tandem Mirror Experiment-Upgrade (TMX-U). Measurements of nonambipolar and ambipolar radial transport show that these transport processes, as well as end losses, can be controlled at modest densities and durations. Central-cell heating methods using ion-cyclotron heating (ICH) and neutral-beam injection have been demonstrated. Potential mesurements with recently developed methods indicate that deep thermal barriers can be established

  7. Results from the Tara tandem mirror experiment

    International Nuclear Information System (INIS)

    Lane, B.G.

    1987-09-01

    A summary of the experimental results from the Tara tandem mirror experiment is presented. Optimization of the fueling configuration, slow wave ion cyclotron heating from a magnetic ''plateau'' using an aperture antenna design, and enhanced stabilization from a magnetic divertor have allowed the attainment of a stable start up plasma (T/sub i,perpendicular/ = 800 - 1500 eV, n/sub e/ = 4 - 5 x 10 12 cm -3 , T/sub e/ = 70 - 80 eV). Plugging experiments using radiofrequency waves near the plug midplane ion cyclotron frequency have proved successful in reducing endloss, while simultaneously leading to an increase in central cell density. The plugging potentials have been limited to approximately the ion parallel temperature. This limitation is due to low frequency instabilities localized in the plug. Axial plugging experiments using electron cyclotron (ECH) resonant microwave radiation in the plug cells have had ambiguous results. Endloss reductions up to 100% have been achieved without build-up of central cell densities or the appearance of the reflected particles at the other end of the machine. We conjecture that rapid radial losses accompany the use of ECH, although the mechanisms for this loss remain unidentified. 9 refs., 9 figs

  8. Transiting Exoplanet Survey Satellite (TESS)

    Science.gov (United States)

    Ricker, G. R.; Clampin, M.; Latham, D. W.; Seager, S.; Vanderspek, R. K.; Villasenor, J. S.; Winn, J. N.

    2012-01-01

    The Transiting Exoplanet Survey Satellite (TESS) will discover thousands of exoplanets in orbit around the brightest stars in the sky. In a two-year survey, TESS will monitor more than 500,000 stars for temporary drops in brightness caused by planetary transits. This first-ever spaceborne all-sky transit survey will identify planets ranging from Earth-sized to gas giants, around a wide range of stellar types and orbital distances. No ground-based survey can achieve this feat. A large fraction of TESS target stars will be 30-100 times brighter than those observed by Kepler satellite, and therefore TESS . planets will be far easier to characterize with follow-up observations. TESS will make it possible to study the masses, sizes, densities, orbits, and atmospheres of a large cohort of small planets, including a sample of rocky worlds in the habitable zones of their host stars. TESS will provide prime targets for observation with the James Webb Space Telescope (JWST), as well as other large ground-based and space-based telescopes of the future. TESS data will be released with minimal delay (no proprietary period), inviting immediate community-wide efforts to study the new planets. The TESS legacy will be a catalog of the very nearest and brightest main-sequence stars hosting transiting exoplanets, thus providing future observers with the most favorable targets for detailed investigations.

  9. TANDEM

    Data.gov (United States)

    Federal Laboratory Consortium — The Tandem Van de Graaff facility provides researchers with beams of more than 40 different types of ions - atoms that have been stripped of their electrons. One of...

  10. Tandem mirror and field-reversed mirror experiments

    Energy Technology Data Exchange (ETDEWEB)

    Coensgen, F.H.; Simonen, T.C.; Turner, W.C.

    1979-08-21

    This paper is largely devoted to tandem mirror and field-reversed mirror experiments at the Lawrence Livermore Laboratory (LLL), and briefly summarizes results of experiments in which field-reversal has been achieved. In the tandem experiment, high-energy, high-density plasmas (nearly identical to 2XIIB plasmas) are located at each end of a solenoid where plasma ions are electrostatically confined by the high positive poentials arising in the end plug plasma. End plug ions are magnetically confined, and electrons are electrostatically confined by the overall positive potential of the system. The field-reversed mirror reactor consists of several small field-reversed mirror plasmas linked together for economic reasons. In the LLL Beta II experiment, generation of a field-reversed plasma ring will be investigated using a high-energy plasma gun with a transverse radial magnetic field. This plasma will be further heated and sustained by injection of intense, high-energy neutral beams.

  11. Neutral beam control systems for the Tandem Mirror Experiment

    International Nuclear Information System (INIS)

    Ross, R.I.

    1979-01-01

    The Tandem Mirror Experiment (TMX) is presently developing the technology and approaches which will be used in larger fusion systems. This paper describes some of the designs which were used in creating the control system for the TMX neutral beams. To create a system of controls that would work near these large, rapid switching current sources required a mixture of different technologies: fiberoptic data transmission, printed circuit and wirewrap techniques, etc

  12. Summary of results from the Tandem Mirror Experiment (TMX)

    International Nuclear Information System (INIS)

    Simonen, T.C.

    1981-01-01

    This report summarizes results from the successful experimental operation of the Tandem Mirror Experiment (TMX) over the period October 1978 through September 1980. The experimental program, summarized by the DOE milestones given in Table 1-1, had three basic phases: (1) an 8-month checkout period, October 1978 through May 1979; (2) a 6-month initial period of operation, June through November 1979, during which the basic principles of the tandem configuration were demonstrated (i.e., plasma confinement was improved over that of a single-cell mirror); and (3) a 10-month period, December 1979 through September 1980, during which the initial TMX results were corroborated by additional diagnostic measurements and many detailed physics investigations were carried out. This report summarizes the early results, presents results of recent data analysis, and outlines areas of ongoing research and data analysis which will be reported in future journal publications

  13. Gas box control system for Tandem Mirror Experiment-Upgrade

    International Nuclear Information System (INIS)

    Bell, H.H. Jr.; Hunt, A.L.; Clower, C.A. Jr.

    1983-01-01

    The Tandem Mirror Experiment-Upgrade (TMX-U) uses several methods to feed gas (usually deuterium) at different energies into the plasma region of the machine. One is an arrangement of eight high-speed piezo-electric valves mounted on special manifolds (gas box) that feed cold gas directly to the plasma. This paper describes the electronic valve control and data acquisition portions of the gas box, which are controlled by a desk-top computer. Various flow profiles have been developed and stored in the control computer for ready access by the operator. The system uses two modes of operation, one that exercises and characterizes the valves and one that operates the valves with the rest of the experiment. Both the valve control signals and the pressure transducers data are recorded on the diagnostics computer so that they are available for experiment analysis

  14. Preliminary pellet injection experiment in the Gamma 10 tandem mirror

    Energy Technology Data Exchange (ETDEWEB)

    Kawamori, Eiichirou; Tamano, Teruo; Nakashima, Yousuke; Yoshikawa, Masayuki; Kobayashi, Shinji; Cho, Teruji; Ishii, Kameo; Yatsu, Kiyoshi [Plasma Research Center, University of Tsukuba, Tsukuba, Ibaraki (Japan); Mase, Atsushi [Advanced Sceince and Technology Center for Cooperative Research, Kyushu University, Kasuga, Fukuoka (Japan)

    2000-07-01

    In the GAMMA 10 tandem mirror, pellet injection experiments have been started as a solution for the density limit problem. This is the first pellet injection experiment in open systems. We describe the possibilities of confinement of pellet fueled particles. For that, we measure the number of end loss particles and compare them with pellet fueled ones in various conditions of confining potentials. The deterioration of confining potential with the pellet injection is a fundamental issue. The results show that the ion confining potential recover faster than central electron temperature due to thermal barrier. We also consider the operating space for fueling method. It is demonstrated that the operating space for pellet injection exceeds gas fueled one on hot ion mode plasmas. (author)

  15. Multifactorial Understanding of Ion Abundance in Tandem Mass Spectrometry Experiments.

    Science.gov (United States)

    Fazal, Zeeshan; Southey, Bruce R; Sweedler, Jonathan V; Rodriguez-Zas, Sandra L

    2013-01-29

    In a bottom-up shotgun approach, the proteins of a mixture are enzymatically digested, separated, and analyzed via tandem mass spectrometry. The mass spectra relating fragment ion intensities (abundance) to the mass-to-charge are used to deduce the amino acid sequence and identify the peptides and proteins. The variables that influence intensity were characterized using a multi-factorial mixed-effects model, a ten-fold cross-validation, and stepwise feature selection on 6,352,528 fragment ions from 61,543 peptide ions. Intensity was higher in fragment ions that did not have neutral mass loss relative to any mass loss or that had a +1 charge state. Peptide ions classified for proton mobility as non-mobile had lowest intensity of all mobility levels. Higher basic residue (arginine, lysine or histidine) counts in the peptide ion and low counts in the fragment ion were associated with lower fragment ion intensities. Higher counts of proline in peptide and fragment ions were associated with lower intensities. These results are consistent with the mobile proton theory. Opposite trends between peptide and fragment ion counts and intensity may be due to the different impact of factor under consideration at different stages of the MS/MS experiment or to the different distribution of observations across peptide and fragment ion levels. Presence of basic residues at all three positions next to the fragmentation site was associated with lower fragment ion intensity. The presence of proline proximal to the fragmentation site enhanced fragmentation and had the opposite trend when located distant from the site. A positive association between fragment ion intensity and presence of sulfur residues (cysteine and methionine) on the vicinity of the fragmentation site was identified. These results highlight the multi-factorial nature of fragment ion intensity and could improve the algorithms for peptide identification and the simulation in tandem mass spectrometry experiments.

  16. Data preparation for asteroseismology with TESS

    Directory of Open Access Journals (Sweden)

    Lund Mikkel N.

    2017-01-01

    Full Text Available The Transiting Exoplanet Survey Satellite (TESS is a NASA Astrophysics Explorer mission. Following its scheduled launch in 2017, TESS will focus on detecting exoplanets around the nearest and brightest stars in the sky, for which detailed follow-up observations are possible. TESS will, as the NASA Kepler mission, include a asteroseismic program that will be organized within the TESS Asteroseismic Science Consortium (TASC, building on the success of the Kepler Asteroseismic Science Consortium (KASC. Within TASC data for asteroseismic analysis will be prepared by the TASC Working Group 0 (WG-0, who will facilitate data to the community via the TESS Asteroseismic Science Operations Center (TASOC, again building on the success of the corresponding KASOC platform for Kepler. Here, we give an overview of the steps being taken within WG-0 to prepare for the upcoming TESS mission.

  17. Data preparation for asteroseismology with TESS

    Science.gov (United States)

    Lund, Mikkel N.; Handberg, Rasmus; Kjeldsen, Hans; Chaplin, William J.; Christensen-Dalsgaard, Jørgen

    2017-10-01

    The Transiting Exoplanet Survey Satellite (TESS) is a NASA Astrophysics Explorer mission. Following its scheduled launch in 2017, TESS will focus on detecting exoplanets around the nearest and brightest stars in the sky, for which detailed follow-up observations are possible. TESS will, as the NASA Kepler mission, include a asteroseismic program that will be organized within the TESS Asteroseismic Science Consortium (TASC), building on the success of the Kepler Asteroseismic Science Consortium (KASC). Within TASC data for asteroseismic analysis will be prepared by the TASC Working Group 0 (WG-0), who will facilitate data to the community via the TESS Asteroseismic Science Operations Center (TASOC), again building on the success of the corresponding KASOC platform for Kepler. Here, we give an overview of the steps being taken within WG-0 to prepare for the upcoming TESS mission.

  18. Thermal Excitation System for Shearography (TESS)

    Science.gov (United States)

    Lansing, Matthew D.; Bullock, Michael W.

    1996-01-01

    One of the most convenient and effective methods of stressing a part or structure for shearographic evaluation is thermal excitation. This technique involves heating the part, often convectively with a heat gun, and then monitoring with a shearography device the deformation during cooling. For a composite specimen, unbonds, delaminations, inclusions, or matrix cracking will deform during cooling differently than other more structurally sound regions and thus will appear as anomalies in the deformation field. However, one of the difficulties that cause this inspection to be dependent on the operator experience is the conventional heating process. Fanning the part with a heat gun by hand introduces a wide range of variability from person to person and from one inspection to the next. The goal of this research effort was to conduct research in the methods of thermal excitation for shearography inspection. A computerized heating system was developed for inspection of 0.61 m (24 in.) square panels. The Thermal Excitation System for Shearography (TESS) provides radiant heating with continuous digital measurement of the surface temperature profile to ensure repeatability. The TESS device functions as an accessory to any electronic shearography device.

  19. Construction and operational experience of the Tandem Mirror Experiment-Upgrade (TMX-U)

    International Nuclear Information System (INIS)

    Chargin, A.K.; Calderon, M.O.; Moore, T.L.

    1983-01-01

    The Tandem Mirror Experiment-Upgrade (TMX-U) incorporates two new features at Lawrence Livermore National Laboratory (LLNL) tandem mirror program, thermal barriers in the end plugs and injection of the neutral beams at several oblique angles. The thermal barriers isolate the electrons in the end plugs from those in the central cell, making it possible to heat them independently with microwaves. In addition, this innovation produces a large potential gradient in the end plugs with lower magnetic fields and lower neutral-beam energies than would be possible in a conventional tandem mirror device. The TMX-U is also designed to test neutral-beam-injection angles as an experimental parameter. We use angles other than 90 0 to produce a plasma with improved microstability

  20. Negotiating Multiple Identities through eTandem Learning Experiences

    Science.gov (United States)

    Yang, Se Jeong; Yi, Youngjoo

    2017-01-01

    Much of eTandem research has investigated either linguistic or cross-cultural aspects of second language (L2) learning, but relatively little is known about issues of identity construction in an eTandem context. Situating the study within theories and research of language learner identity, we examined ways in which two adult L2 learners (a Korean…

  1. LLNL Tandem Mirror Experiment (TMX) upgrade vacuum system

    International Nuclear Information System (INIS)

    Pickles, W.L.; Chargin, A.K.; Drake, R.P.

    1981-01-01

    TMX Upgrade is a large, tandem, magnetic-mirror fusion experiment with stringent requirements on base pressure (10 -8 torr), low H reflux from the first walls, and peak gas pressure (5 x 10 -7 torr) due to neutral beam gas during plasma operation. The 225 m 3 vacuum vessel is initially evacuated by turbopumps. Cryopumps provide a continuous sink for gases other than helium, deuterium, and hydrogen. The neutral beam system introduces up to 480 l/s of H or D. The hydrogen isotopes are pumped at very high speed by titanium sublimed onto two cylindrical radially separated stainless steel quilted liners with a total surface area of 540 m 2 . These surfaces (when cooled to about 80 0 K) provide a pumping speed of 6 x 10 7 l/s for hydrogen. The titanium getter system is programmable and is used for heating as well as gettering. The inner plasma liner can be operated at elevated temperatures to enhance migration of gases away from the surfaces close to the plasma. Glow discharge cleaning is part of the pumpdown procedure. The design features are discussed in conjunction with the operating procedures developed to manage the dynamic vacuum conditions

  2. Tess of the D'Urbervilles

    NARCIS (Netherlands)

    Hardy, Thomas

    2005-01-01

    Tess Durbeyfield, an innocent village girl, is seduced by a wealthy rake, Alec D'Urberville. Though he makes her pregnant she does not love him and and leaves him to return to her home in disgrace. Some time after the baby's death Tess meets her true love Angel Clare, but they cannot escape the

  3. TESS Ground System Operations and Data Products

    Science.gov (United States)

    Glidden, Ana; Guerrero, Natalia; Fausnaugh, Michael; TESS Team

    2018-01-01

    We describe the ground system operations for processing data from the Transiting Exoplanet Survey Satellite (TESS), highlighting the role of the Science Operations Center (SOC). TESS is a spaced-based (nearly) all-sky mission, designed to find small planets around nearby bright stars using the transit method. We detail the flow of data from pixel measurements on the instrument to final products available at the Mikulski Archive for Space Telescopes (MAST). The ground system relies on a host of players to process the data, including the Payload Operations Center at MIT, the Science Processing Operation Center at NASA Ames, and the TESS Science Office, led by the Harvard-Smithsonian Center for Astrophysics and MIT. Together, these groups will deliver TESS Input Catalog, instrument calibration models, calibrated target pixels and full frame images, threshold crossing event reports, two-minute light curves, and the TESS Objects of Interest List.

  4. TMX-U [Tandem Mirror Experiment-Upgrade]: Final report, Volume 2

    International Nuclear Information System (INIS)

    Porter, G.D.

    1988-01-01

    This paper discusses the plasma control and the physics accomplishments of the Tandem Mirror Experiment-Upgrade. This particular volume discusses fueling, ion heating, Fokker-Planck modeling, plasma stability and technical development. 270 refs

  5. TMX-U [Tandem Mirror Experiment-Upgrade]: Final report, Volume 1

    International Nuclear Information System (INIS)

    Porter, G.D.

    1988-01-01

    This paper discusses the plasma control and the physics accomplishments of the Tandem Mirror Experiment-Upgrade. This particular volume discusses potential measurements, plasma confinement, and hot electron and ion physics. 230 refs

  6. Ion cyclotron resonant heating 2 x 1700 loop antenna for the Tandem Mirror Experiment-Upgrade

    International Nuclear Information System (INIS)

    Brooksby, C.A.; Ferguson, S.W.; Molvik, A.W.; Barter, J.

    1985-01-01

    This paper reviews the mechanical design and improvements that have taken place on the loop type ion cyclotron resonance heating (ICRH) antennas that are located in the center cell region of the Tandem Mirror Experiment-Upgrade (TMX-U)

  7. The Teaching of "Tess": A Disagreement.

    Science.gov (United States)

    Williamson, David

    1982-01-01

    Argues that the study of "Tess of the D'Urbervilles" will provoke both agreement and disagreement in its premises and its particular judgments, but that the ensuing thought and discussion can constitute an education in novel reading. (HOD)

  8. Experiments on hot-electron ECRH in the Tandem Mirror Experiment-Upgrade

    International Nuclear Information System (INIS)

    Stallard, B.W.

    1983-01-01

    Experiments have begun on the Tandem Mirror Experiment Upgrade (TMX-U) using electron-cyclotron resonant heating (ECRH) to generate the hot electron populations required for thermal barrier operation (Energy E/sub eh/ approx. 50 keV, density n/sub eh/ 12 , and hot-to-cold fraction n/sub eh/n approx. 0.9). For this operation, rf power produced by 28-GHz gyrotrons is injected with extraordinary mode polarization at both fundamental and second harmonic locations. Our initial experiments, which concentrated on startup of the hot electrons, were carried out at low density ( 12 cm - 3 ) where Fokker-Planck calculations predict high heating efficiency when the electron temperature (T/sub e/) is low. Under these conditions, we produced substantial hot electron populations (diamagnetic energy > 400 J, E/sub eh/ in the range of 15 to 50 keV, and n/sub eh//n > 0.5)

  9. Tomographic extreme-ultraviolet spectrographs: TESS.

    Science.gov (United States)

    Cotton, D M; Stephan, A; Cook, T; Vickers, J; Taylor, V; Chakrabarti, S

    2000-08-01

    We describe the system of Tomographic Extreme Ultraviolet (EUV) SpectrographS (TESS) that are the primary instruments for the Tomographic Experiment using Radiative Recombinative Ionospheric EUV and Radio Sources (TERRIERS) satellite. The spectrographs were designed to make high-sensitivity {80 counts/s)/Rayleigh [one Rayleigh is equivalent to 10(6) photons/(4pi str cm(2)s)}, line-of-sight measurements of the oi 135.6- and 91.1-nm emissions suitable for tomographic inversion. The system consists of five spectrographs, four identical nightglow instruments (for redundancy and added sensitivity), and one instrument with a smaller aperture to reduce sensitivity and increase spectral resolution for daytime operation. Each instrument has a bandpass of 80-140 nm with approximately 2- and 1-nm resolution for the night and day instruments, respectively. They utilize microchannel-plate-based two-dimensional imaging detectors with wedge-and-strip anode readouts. The instruments were designed, fabricated, and calibrated at Boston University, and the TERRIERS satellite was launched on 18 May 1999 from Vandenberg Air Force Base, California.

  10. Development of pixellated Ir-TESs

    Science.gov (United States)

    Zen, Nobuyuki; Takahashi, Hiroyuki; Kunieda, Yuichi; Damayanthi, Rathnayaka M. T.; Mori, Fumiakira; Fujita, Kaoru; Nakazawa, Masaharu; Fukuda, Daiji; Ohkubo, Masataka

    2006-04-01

    We have been developing Ir-based pixellated superconducting transition edge sensors (TESs). In the area of material or astronomical applications, the sensor with few eV energy resolution and over 1000 pixels imaging property is desired. In order to achieve this goal, we have been analyzing signals from pixellated TESs. In the case of a 20 pixel array of Ir-TESs, with 45 μm×45 μm pixel sizes, the incident X-ray signals have been classified into 16 groups. We have applied numerical signal analysis. On the one hand, the energy resolution of our pixellated TES is strongly degraded. However, using pulse shape analysis, we can dramatically improve the resolution. Thus, we consider that the pulse signal analysis will lead this device to be used as a practical photon incident position identifying TES.

  11. Development of pixellated Ir-TESs

    International Nuclear Information System (INIS)

    Zen, Nobuyuki; Takahashi, Hiroyuki; Kunieda, Yuichi; Dayanthi, Rathnayaka M.T.; Mori, Fumiakira; Fujita, Kaoru; Nakazawa, Masaharu; Fukuda, Daiji; Ohkubo, Masataka

    2006-01-01

    We have been developing Ir-based pixellated superconducting transition edge sensors (TESs). In the area of material or astronomical applications, the sensor with few eV energy resolution and over 1000 pixels imaging property is desired. In order to achieve this goal, we have been analyzing signals from pixellated TESs. In the case of a 20 pixel array of Ir-TESs, with 45 μmx45 μm pixel sizes, the incident X-ray signals have been classified into 16 groups. We have applied numerical signal analysis. On the one hand, the energy resolution of our pixellated TES is strongly degraded. However, using pulse shape analysis, we can dramatically improve the resolution. Thus, we consider that the pulse signal analysis will lead this device to be used as a practical photon incident position identifying TES

  12. Status of the Tandem Mirror Experiment-Upgrade (TMX-U) diagnostic system

    International Nuclear Information System (INIS)

    Coutts, G.W.; Coffield, F.E.; Hornady, R.S.

    1983-01-01

    This paper presents the current status of the Tandem Mirror Experiment-Upgrade (TMX-U) diagnostics system. For the initial instruments active on TMX-U, the expansions or upgrades that have been implemented are outlined. For the newly added systems, more implementation details are presented

  13. Design for the magnetic field requirements of the tandem mirror experiment

    International Nuclear Information System (INIS)

    Chen, F.K.; Chargin, A.K.; Denhoy, B.S.; Waugh, A.F.

    1977-01-01

    The tandem mirror magnetic geometry is described, followed by an analysis of the magnet set designed to meet the requirements of the TMX experiment. The final magnet line-up is composed of a baseball coil with two C coils for each plug, six solenoidal coils for the central cell, and two RC coils plus one octupole coil for each transition

  14. The Toxic Exposure Surveillance System (TESS): Risk assessment and real-time toxicovigilance across United States poison centers

    International Nuclear Information System (INIS)

    Watson, William A.; Litovitz, Toby L.; Belson, Martin G.; Funk Wolkin, Amy B.; Patel, Manish; Schier, Joshua G.; Reid, Nicole E.; Kilbourne, Edwin; Rubin, Carol

    2005-01-01

    The Toxic Exposure Surveillance System (TESS) is a uniform data set of US poison centers cases. Categories of information include the patient, the caller, the exposure, the substance(s), clinical toxicity, treatment, and medical outcome. The TESS database was initiated in 1985, and provides a baseline of more than 36.2 million cases through 2003. The database has been utilized for a number of safety evaluations. Consideration of the strengths and limitations of TESS data must be incorporated into data interpretation. Real-time toxicovigilance was initiated in 2003 with continuous uploading of new cases from all poison centers to a central database. Real-time toxicovigilance utilizing general and specific approaches is systematically run against TESS, further increasing the potential utility of poison center experiences as a means of early identification of potential public health threats

  15. The Toxic Exposure Surveillance System (TESS): risk assessment and real-time toxicovigilance across United States poison centers.

    Science.gov (United States)

    Watson, William A; Litovitz, Toby L; Belson, Martin G; Wolkin, Amy B Funk; Patel, Manish; Schier, Joshua G; Reid, Nicole E; Kilbourne, Edwin; Rubin, Carol

    2005-09-01

    The Toxic Exposure Surveillance System (TESS) is a uniform data set of US poison centers cases. Categories of information include the patient, the caller, the exposure, the substance(s), clinical toxicity, treatment, and medical outcome. The TESS database was initiated in 1985, and provides a baseline of more than 36.2 million cases through 2003. The database has been utilized for a number of safety evaluations. Consideration of the strengths and limitations of TESS data must be incorporated into data interpretation. Real-time toxicovigilance was initiated in 2003 with continuous uploading of new cases from all poison centers to a central database. Real-time toxicovigilance utilizing general and specific approaches is systematically run against TESS, further increasing the potential utility of poison center experiences as a means of early identification of potential public health threats.

  16. Tandem Mirror Experiment Upgrade (TMX-U) overview-recent events

    International Nuclear Information System (INIS)

    Calderon, M.O.; Bell, H.H.

    1985-01-01

    Since its construction and commissioning was completed in the winter of 1981, the Tandem Mirror Experiment Upgrade (TMX-U) has been conducting tandem mirror thermal barrier experiments. The work, following the fall of 1983 when strong plugging with thermal barriers was achieved, has been directed toward controlling radial transport and forming thermal barriers with high density and Beta. This paper describes the overall engineering component of these efforts. Major changes to the machine have included vacuum improvements, changes to the Electron and Ion Cyclotron Resonance Heating systems (ECRH and ICRH), and the installation of a Plasma Potential Control system (PPC) for radial transport reduction. TMX-U operates an extensive diagnostics system that acquires data from 21 types of diagnostic instruments with more than 600 channels, in addition to 246 machine parameters. The changes and additions will be presented. The closing section of this paper will describe the initial study work for a proposed TMX-U octupole configured machine

  17. Investigation of RF heating for tandem-mirror experiments. Phaedrus status report, Summer, 1983

    International Nuclear Information System (INIS)

    Breun, R.A.

    1983-01-01

    This report includes a summary description of experimental results obtained during the period of June, July and August, September 15, 1983 and details of major hardware changes to the Phaedrus experimental facility. Approximately one-third of the time was used to optimize conditions for neutral beam buildup. The remainder of the time was used to advance understanding of the RF heated and fueled tandem mirror experiments

  18. Plasma diagnostic techniques in thermal-barrier tandem-mirror fusion experiments

    International Nuclear Information System (INIS)

    Silver, E.H.; Clauser, J.F.; Carter, M.R.; Failor, B.H.; Foote, J.H.; Hornady, R.S.; James, R.A.; Lasnier, C.J.; Perkins, D.E.

    1986-01-01

    We review two classes of plasma diagnostic techniques used in thermal-barrier tandem-mirror fusion experiments. The emphasis of the first class is to study mirror-trapped electrons at the thermal-barrier location. The focus of the second class is to measure the spatial and temporal behavior of the plasma space potential at various axial locations. The design and operation of the instruments in these two categories are discussed and data that are representative of their performance is presented

  19. Technician support for operation and maintenance of large fusion experiments: the tandem mirror experiment upgrade (TMX-U) approach

    International Nuclear Information System (INIS)

    Mattson, G.E.

    1983-01-01

    As experiments continue to grow in size and complexity, a few technicians will no longer be able to maintain and operate the complete experiment. Specialization is becoming the norm. Subsystems are becoming very large and complex, requiring a great deal of experience and training for technicians to become qualified maintenance/operation personnel. Formal in-house and off-site programs supplement on-the-job training to fulfill the qualification criteria. This paper presents the Tandem Mirror Experiment-Upgrade (TMX-U) approach to manpower staffing, some problems encountered, possible improvements, and safety considerations for the successful operation of a large experimental facility

  20. The TESS Science Processing Operations Center

    Science.gov (United States)

    Jenkins, Jon M.; Twicken, Joseph D.; McCauliff, Sean; Campbell, Jennifer; Sanderfer, Dwight; Lung, David; Mansouri-Samani, Masoud; Girouard, Forrest; Tenenbaum, Peter; Klaus, Todd; hide

    2016-01-01

    The Transiting Exoplanet Survey Satellite (TESS) will conduct a search for Earth's closest cousins starting in early 2018 and is expected to discover approximately 1,000 small planets with R(sub p) less than 4 (solar radius) and measure the masses of at least 50 of these small worlds. The Science Processing Operations Center (SPOC) is being developed at NASA Ames Research Center based on the Kepler science pipeline and will generate calibrated pixels and light curves on the NASA Advanced Supercomputing Division's Pleiades supercomputer. The SPOC will also search for periodic transit events and generate validation products for the transit-like features in the light curves. All TESS SPOC data products will be archived to the Mikulski Archive for Space Telescopes (MAST).

  1. Optimizing the TESS Planet Finding Pipeline

    Science.gov (United States)

    Chitamitara, Aerbwong; Smith, Jeffrey C.; Tenenbaum, Peter; TESS Science Processing Operations Center

    2017-10-01

    The Transiting Exoplanet Survey Satellite (TESS) is a new NASA planet finding all-sky survey that will observe stars within 200 light years and 10-100 times brighter than that of the highly successful Kepler mission. TESS is expected to detect ~1000 planets smaller than Neptune and dozens of Earth size planets. As in the Kepler mission, the Science Processing Operations Center (SPOC) processing pipeline at NASA Ames Research center is tasked with calibrating the raw pixel data, generating systematic error corrected light curves and then detecting and validating transit signals. The Transiting Planet Search (TPS) component of the pipeline must be modified and tuned for the new data characteristics in TESS. For example, due to each sector being viewed for as little as 28 days, the pipeline will be identifying transiting planets based on a minimum of two transit signals rather than three, as in the Kepler mission. This may result in a significantly higher false positive rate. The study presented here is to measure the detection efficiency of the TESS pipeline using simulated data. Transiting planets identified by TPS are compared to transiting planets from the simulated transit model using the measured epochs, periods, transit durations and the expected detection statistic of injected transit signals (expected MES). From the comparisons, the recovery and false positive rates of TPS is measured. Measurements of recovery in TPS are then used to adjust TPS configuration parameters to maximize the planet recovery rate and minimize false detections. The improvements in recovery rate between initial TPS conditions and after various adjustments will be presented and discussed.

  2. TESS Lens-Bezel Assembly Modal Testing

    Science.gov (United States)

    Dilworth, Brandon J.; Karlicek, Alexandra

    2017-01-01

    The Transiting Exoplanet Survey Satellite (TESS) program, led by the Kavli Institute for Astrophysics and Space Research at the Massachusetts Institute of Technology (MIT) will be the first-ever spaceborne all-sky transit survey. MIT Lincoln Laboratory is responsible for the cameras, including the lens assemblies, detector assemblies, lens hoods, and camera mounts. TESS is scheduled to be launched in August of 2017 with the primary goal to detect small planets with bright host starts in the solar neighborhood, so that detailed characterizations of the planets and their atmospheres can be performed. The TESS payload consists of four identical cameras and a data handling unit. Each camera consists of a lens assembly with seven optical elements and a detector assembly with four charge-coupled devices (CCDs) including their associated electronics. The optical prescription requires that several of the lenses are in close proximity to a neighboring element. A finite element model (FEM) was developed to estimate the relative deflections between each lens-bezel assembly under launch loads to predict that there are adequate clearances preventing the lenses from making contact. Modal tests using non-contact response measurements were conducted to experimentally estimate the modal parameters of the lens-bezel assembly, and used to validate the initial FEM assumptions. Key Words Non-contact measurements, modal analysis, model validation

  3. The TESS Input Catalog and Selection of Targets for the TESS Transit Search

    Science.gov (United States)

    Pepper, Joshua; Stassun, Keivan G.; Paegert, Martin; Oelkers, Ryan; De Lee, Nathan Michael; Torres, Guillermo; TESS Target Selection Working Group

    2018-01-01

    The TESS mission will photometrically survey millions of the brightest stars over almost the entire the sky to detect transiting exoplanets. A key step to enable that search is the creation of the TESS Input Catalog (TIC), a compiled catalog of 700 million stars and galaxies with observed and calculated parameters. From the TIC we derive the Candidate Target List (CTL) to identify target stars for the 2-minute TESS postage stamps. The CTL is designed to identify the best stars for the detection of small planets, which includes all bright cool dwarf stars in the sky. I will describe the target selection strategy, the distribution of stars in the current CTL, and how both the TIC and CTL will expand and improve going forward.

  4. Circular waveguide systems for electron-cyclotron-resonant heating of the tandem mirror experiment-upgrade

    International Nuclear Information System (INIS)

    Felker, B.; Calderon, M.O.; Chargin, A.K.

    1983-01-01

    Extensive use of electron cyclotron resonant heating (ECRH) in the Tandem Mirror Experiment-Upgrade (TMX-U) requires continuous development of components to improve efficiency, increase reliability, and deliver power to new locations with respect to the plasma. We have used rectangular waveguide components on the experiment and have developed, tested, and installed circular waveguide components. We replaced the rectangular with the circular components because of the greater transmission efficiency and power-handling capability of the circular ones. Design, fabrication, and testing of all components are complete for all systems. In this paper we describe the design criteria for the system

  5. TMX tandem-mirror experiments and thermal-barrier theoretical studies

    International Nuclear Information System (INIS)

    Simonen, T.C.; Baldwin, D.E.; Allen, S.L.

    1982-01-01

    This paper describes recent analysis of energy confinement in the Tandem Mirror Experiment (TMX). TMX data also indicates that warm plasma limits the amplitude of the anisotropy driven Alfven ion cyclotron (AIC) mode. Theoretical calculations show strong AIC stabilization with off-normal beam injection as planned in TMX-U and MFTF-B. This paper reports results of theoretical analysis of hot electrons in thermal barriers including electron heating calculations by Monte Carlo and Fokker-Planck codes and analysis of hot electron MHD and microinstability. Initial results from the TMX-U experiment are presented which show the presence of sloshing ions

  6. Tandem-Mirror Experiment-Upgrade neutral pressure measurement diagnostic systems

    International Nuclear Information System (INIS)

    Pickles, W.L.; Allen, S.L.; Hill, D.N.; Hunt, A.L.; Simonen, T.C.

    1985-01-01

    The Tandem-Mirror Experiment-Upgrade (TMX-U) has a large and complex system of Bayard--Alpert, magnetron, and Penning gauges, in addition to mass spectrometers (RGA), all of which measure neutral pressures in the many internal regions of TMX-U. These pressure measurements are used as part of the confinement physics data base as well as for management of the TMX-U vacuum system. Dynamic pressures are modeled by a coupled-volumes simulation code, which includes wall reflux, getter pumping, and plasma pumping

  7. Neutral particle time-of-flight analyzer for the Tandem Mirror Experiment Upgrade (TMX-U)

    International Nuclear Information System (INIS)

    Hibbs, S.M.; Carter, M.R.; Coutts, G.W.

    1985-01-01

    We describe the design and performance of a time-of-flight (ToF) analyzer being built for installation on the east end cell of the Tandem Mirror Experiment Upgrade (TMX-U). Its primary purpose is to measure the velocity distribution of escaping charge exchange neutral particles having energies between 20 and 5000 electron volts (eV). It also enables direct determination of the thermal barrier potential when used in conjunction with the plasma potential diagnostic and the end loss ion spectrometer. In addition, it can measure the velocity distribution of passing ions leaving the central cell and of ions trapped in the thermal barrier

  8. The TESS-HERMES survey data release 1

    DEFF Research Database (Denmark)

    Sharma, Sanjib; Stello, Dennis; Buder, Sven

    2018-01-01

    -Australian Telescope as part of the TESS-HERMES survey. Comparing our results with the TESS Input Catalogue (TIC) shows that the TIC is generally efficient in separating dwarfs and giants, but it has flagged more than 100 cool dwarfs (T-eff

  9. Analyzing Exertion of Hardy's Tragic Effect in "Tess"

    Science.gov (United States)

    Yang, Wei

    2009-01-01

    This paper begins with a brief introduction to [Thomas] Hardy's whole life and his works, especially this novel "Tess [of the D'Urbervilles]" and points out the tragic effect's importance and Hardy's tragic idea. Linked to this tragic effect, this paper analyzes the nice application in "Tess." At last, we can understand more…

  10. Hot-electron plasma formation and confinement in the tandem mirror experiment-upgrade

    International Nuclear Information System (INIS)

    Ress, D.B.

    1988-06-01

    The tandem mirror experiment-upgrade (TMX-U) at the Lawrence Livermore National Laboratory (LLNL) is the first experiment to investigate the thermal-barrier tandem-mirror concept. One attractive feature of the tandem magnetic mirror as a commercial power reactor is that the fusion reactions occur in an easily accessible center-cell. On the other hand, complicated end-cells are necessary to provide magnetohydrodynamic (MHD) stability and improved particle confinement of the center-cell plasma. In these end-cells, enhanced confinement is achieved with a particular axial potential profile that is formed with electron-cyclotron range-of-frequency heating (ECRF heating, ECRH). By modifying the loss rates of electrons at spatially distinct locations within the end-cells, the ECRH can tailor the plasma potential profile in the desired fashion. Specifically, the thermal-barrier concept requires generation of a population of energetic electrons near the midplane of each end-cell. To be effective, the transverse (to the magnetic field) spatial structure of the hot-electron plasma must be fairly uniform. In this dissertation we characterize the spatial structure of the ECRH-generated plasma, and determine how the structure builds up in time. Furthermore, the plasma should efficiently absorb the ECRF power, and a large fraction of the electrons must be well confined near the end-cell midplane. Therefore, we also examine in detail the ECRH power balance, determining how the ECRF power is absorbed by the plasma, and the processes through which that power is confined and lost. 43 refs., 69 figs., 6 tabs

  11. Hot-electron plasma formation and confinement in the Tandem Mirror Experiment-Upgrade

    International Nuclear Information System (INIS)

    Ress, D.B.

    1988-01-01

    Electron-cyclotron range-of-frequency heating (ECRH) at 28 GHz is used to create a population of mirror-confined hot electrons in the Tandem Mirror Experiment-Upgrade (TMX-U). Generation of a large fraction of such electrons within each end-cell of TMX-U is essential to the formation of the desired electrostatic potential profile of the thermal-barrier tandem mirror. The formation and confinement of the ECRH-generated hot-electron plasma was investigated with a variety of diagnostic instruments, including a novel instrumented limiter probe. The author characterized the spatial structure of the hot-electron plasma. Details of the heating process cause the plasma to separate into two regions: a halo, consisting entirely of energetic electrons, and a core, which is dominated by cooler electrons. The plasma structure forms rapidly under the action of second-harmonic ECRH. Fundamental ECRH, which is typically applied simultaneously, is only weakly absorbed and generally does not create energetic electrons. The ECRH-generated plasma displays several loss mechanisms. Hot electrons in the halo region, with T e ∼ 30 keV, are formed by localized ECRH near the plasma boundary, and are lost through a radial process involving open magnetic-curvature-drift surfaces

  12. Status of the TESS Science Processing Operations Center

    Science.gov (United States)

    Jenkins, Jon Michael; Caldwell, Douglas A.; Davies, Misty; Li, Jie; Morris, Robert L.; Rose, Mark; Smith, Jeffrey C.; Tenenbaum, Peter; Ting, Eric; Twicken, Joseph D.; Wohler, Bill

    2018-06-01

    The Transiting Exoplanet Survey Satellite (TESS) was selected by NASA’s Explorer Program to conduct a search for Earth’s closest cousins starting in 2018. TESS will conduct an all-sky transit survey of F, G and K dwarf stars between 4 and 12 magnitudes and M dwarf stars within 200 light years. TESS is expected to discover 1,000 small planets less than twice the size of Earth, and to measure the masses of at least 50 of these small worlds. The TESS science pipeline is being developed by the Science Processing Operations Center (SPOC) at NASA Ames Research Center based on the highly successful Kepler science pipeline. Like the Kepler pipeline, the TESS pipeline provides calibrated pixels, simple and systematic error-corrected aperture photometry, and centroid locations for all 200,000+ target stars observed over the 2-year mission, along with associated uncertainties. The pixel and light curve products are modeled on the Kepler archive products and will be archived to the Mikulski Archive for Space Telescopes (MAST). In addition to the nominal science data, the 30-minute Full Frame Images (FFIs) simultaneously collected by TESS will also be calibrated by the SPOC and archived at MAST. The TESS pipeline searches through all light curves for evidence of transits that occur when a planet crosses the disk of its host star. The Data Validation pipeline generates a suite of diagnostic metrics for each transit-like signature, and then extracts planetary parameters by fitting a limb-darkened transit model to each potential planetary signature. The results of the transit search are modeled on the Kepler transit search products (tabulated numerical results, time series products, and pdf reports) all of which will be archived to MAST. Synthetic sample data products are available at https://archive.stsci.edu/tess/ete-6.html.Funding for the TESS Mission has been provided by the NASA Science Mission Directorate.

  13. The magnet power control system for the tandem mirror experiment-upgrade

    International Nuclear Information System (INIS)

    Bell, H.H.

    1983-01-01

    This paper describes the desktop computer/CAMAC based system that controls the power source for the Tandem Mirror Experiment-Upgrade (TMX-U) magnet power system. Presently it contains 42 dc rectifier power supplies connected to 24 magnet coils arranged in 17 circuits. During each shot, the system delivers 22.6 MW dc to the magnets for about 3 s. The system is presently being changed to add six power supplies, two solenoidal throttle coils, and two reverse C-coils. When complete, the delivered power will increase to 36.9 MW. The closed-loop control system usually provides current (and thus, magnetic field) that is within 1% of the requested current. Achieving this accuracy required using grounding, shielding, and isolation methods to reduce noise and related problems

  14. Review of the Tandem Mirror Experiment-Upgrade (TMX-U) machine-parameter-instrumentation system

    International Nuclear Information System (INIS)

    Kane, R.J.; Coffield, F.E.; Coutts, G.W.; Hornady, R.S.

    1983-01-01

    The Tandem Mirror Experiment-Upgrade (TMX-U) machine consists of seven major machine subsystems: magnet system, neutral beam system, microwave heating (ECRH), ion heating (ICRH), gas fueling, stream guns, and vacuum system. Satisfactory performance of these subsystems is necessary to achieve the experimental objectives planned for TMX-U operations. Since the performance quality of the subsystem is important and can greatly affect plasma parameters, a 233-channel instrumentation system has been installed. Data from the instrumentation system are acquired and stored with the plasma diagnostic information. Thus, the details of the machine performance are available during post-shot analysis. This paper describes all the machine-parameter-instrumentation hardware, presents some typical data, and outlines how the data are used

  15. Applications of small computers for systems control on the Tandem Mirror Experiment-Upgrade

    International Nuclear Information System (INIS)

    Bork, R.G.; Kane, R.J.; Moore, T.L.

    1983-01-01

    Desktop computers operating into a CAMAC-based interface are used to control and monitor the operation of the various subsystems on the Tandem Mirror Experiment-Upgrade (TMX-U) at Lawrence Livermore National Laboratory (LLNL). These systems include: shot sequencer/master timing, neutral beam control (four consoles), magnet power system control, ion-cyclotron resonant heating (ICRH) control, thermocouple monitoring, getter system control, gas fueling system control, and electron-cyclotron resonant heating (ECRH) monitoring. Two additional computers are used to control the TMX-U neutral beam test stand and provide computer-aided repair/test and development of CAMAC modules. These machines are usually programmed in BASIC, but some codes have been interpreted into assembly language to increase speed. Details of the computer interfaces and system complexity are described as well as the evolution of the systems to their present states

  16. The TESS-HERMES survey data release 1: high-resolution spectroscopy of the TESS southern continuous viewing zone

    Science.gov (United States)

    Sharma, Sanjib; Stello, Dennis; Buder, Sven; Kos, Janez; Bland-Hawthorn, Joss; Asplund, Martin; Duong, Ly; Lin, Jane; Lind, Karin; Ness, Melissa; Huber, Daniel; Zwitter, Tomaz; Traven, Gregor; Hon, Marc; Kafle, Prajwal R.; Khanna, Shourya; Saddon, Hafiz; Anguiano, Borja; Casey, Andrew R.; Freeman, Ken; Martell, Sarah; De Silva, Gayandhi M.; Simpson, Jeffrey D.; Wittenmyer, Rob A.; Zucker, Daniel B.

    2018-01-01

    The Transiting Exoplanet Survey Satellite (TESS) will provide high-precision time series photometry for millions of stars with at least a half-hour cadence. Of particular interest are the circular regions of 12° radius centred around the ecliptic poles that will be observed continuously for a full year. Spectroscopic stellar parameters are desirable to characterize and select suitable targets for TESS, whether they are focused on exploring exoplanets, stellar astrophysics or Galactic archaeology. Here, we present spectroscopic stellar parameters (Teff, log g, [Fe/H], v sin i, vmicro) for about 16 000 dwarf and subgiant stars in TESS' southern continuous viewing zone. For almost all the stars, we also present Bayesian estimates of stellar properties including distance, extinction, mass, radius and age using theoretical isochrones. Stellar surface gravity and radius are made available for an additional set of roughly 8500 red giants. All our target stars are in the range 10 using the High Efficiency and Resolution Multi-Element Spectrograph (HERMES; R ∼ 28 000) at the Anglo-Australian Telescope as part of the TESS-HERMES survey. Comparing our results with the TESS Input Catalogue (TIC) shows that the TIC is generally efficient in separating dwarfs and giants, but it has flagged more than 100 cool dwarfs (Teff < 4800 K) as giants, which ought to be high-priority targets for the exoplanet search. The catalogue can be accessed via http://www.physics.usyd.edu.au/tess-hermes/, or at Mikulski Archive for Space Telescopes (MAST).

  17. The TESS database. Use in product safety assessment.

    Science.gov (United States)

    Litovitz, T

    1998-01-01

    The Toxic Exposure Surveillance System or TESS is a comprehensive poisoning surveillance database maintained by the American Association of Poison Control Centers. It now includes data on more than 20.3 million human poison exposures reported to US poison centres. TESS data are submitted by 67 of the 75 US poison control centres, covering 87% of the US population. Reports to US poison centres included in TESS originate both from the general public and from health professionals (12.9%) and include both patients managed at home or at the site of the exposure (73.6%) and those managed in hospitals, emergency departments, or other healthcare facilities (22.8%). TESS data are used by the pharmaceutical industry to monitor or defend product safety, by regulatory agencies proposing new regulations or considering new approvals or over-the-counter switches, and by clinical researchers attempting to characterise toxicity profiles or determine treatment protocols. TESS is a key component of an effective post-marketing surveillance programme, allowing early identification of previously unsuspected hazards, and early changes in formulations, labelling, or packaging when needed, thereby minimising injuries, deaths and product liability. Deaths, severe outcomes and comparisons of poisoning outcomes and hospitalisation rates between products or product categories are used to identify safety outliers. TESS data for each case of poisoning include identification of the substances implicated (including brand and formulation where known), patient age, outcome, specific clinical effects, exposure route, reason for the exposure (unintentional, suicidal, therapeutic error, etc.), antidotes used and the level of healthcare intervention utilised. Pharmaceuticals are implicated in 42% of TESS poisoning cases. About 53% of all cases of poisoning occur in children under 6 years of age. Of the more than 2.1 million cases reported to TESS in 1996, 123,095 (5.7%) were therapeutic errors and 32

  18. Summary of Thomson-scattering data from the Tandem Mirror Experiment (TMX)

    International Nuclear Information System (INIS)

    Goodman, R.K.

    1982-01-01

    We provide a synthesis of our Thomson-scattering measurements of electron temperature (T/sub e/) and density (n/sub e/) for the Tandem Mirror Experiment (TMX). TMX operated in two modes - high and low T/sub e/. When performing in the high T/sub e/ mode (in general > 100 eV), heating the central-cell ions with neutral beams raised T/sub e/ in the end plug. We achieved a maximum T/sub e/ of 260 eV in the east end plug. Specifically, our experiments demonstrated that in the end plug, the radial T/sub e/ profiles were flat to r = 5 cm; the ratio of potential (phi/sub p/) to T/sub e/ ranged between four and six. In addition, we found that although T/sub e/ in the central cell was generally comparable to that in the plug, it was often not constant along a magnetic field line. Under some conditions a non-Maxwellian electron distribution may have been present

  19. Ion Cyclotron Resonant Heating 2 X 1700 loop antenna for the Tandem Mirror Experiment-Upgrade

    International Nuclear Information System (INIS)

    Brooksby, C.A.; Ferguson, S.W.; Molvik, A.W.; Barter, J.

    1986-01-01

    This paper reviews the mechanical design and improvements that have taken place on the loop type ion cyclotron resonance heating (ICRH) antennas that are located in the center cell region of the Tandem Mirror Experiment-Upgrade (TMX-U). A computer code (JASON) was used to design getter-shielded antenna supports that will hold off very high voltages (83 kV, DC) over a small insulator distance (2.25 inches) in a vacuum of 10/sup -5/ Torr. The authors also added corona shields on the ceramic-to-metal joints of the matching network capacitors. The system now operates reliably with peak radio frequency (RF) voltages of 40 kV at 2-to-4- MHz frequency and power levels up to 200 kW. The authors have just installed a new loop antenna in the east part of the central cell where the slot antenna was located. This antenna uses two of the slot's internal coax lines and the external matching network. The feedthroughs designed by Lawrence Livermore National Laboratory (LLNL) were replaced with two high-voltage RF feedthroughs designed by Oak Ridge National Laboratory (ORNL)

  20. Nickel-hydrogen battery design for the Transporter Energy Storage Subsystem (TESS)

    Science.gov (United States)

    Lapinski, John R.; Bourland, Deborah S.

    1992-01-01

    Information is given in viewgraph form on nickel hydrogen battery design for the transporter energy storage subsystem (TESS). Information is given on use in the Space Station Freedom, the launch configuration, use in the Mobile Servicing Center, battery design requirements, TESS subassembley design, proof of principle testing of a 6-cell battery, possible downsizing of TESS to support the Mobile Rocket Servicer Base System (MBS) redesign, TESS output capacity, and cell testing.

  1. TESS: A RELATIVISTIC HYDRODYNAMICS CODE ON A MOVING VORONOI MESH

    International Nuclear Information System (INIS)

    Duffell, Paul C.; MacFadyen, Andrew I.

    2011-01-01

    We have generalized a method for the numerical solution of hyperbolic systems of equations using a dynamic Voronoi tessellation of the computational domain. The Voronoi tessellation is used to generate moving computational meshes for the solution of multidimensional systems of conservation laws in finite-volume form. The mesh-generating points are free to move with arbitrary velocity, with the choice of zero velocity resulting in an Eulerian formulation. Moving the points at the local fluid velocity makes the formulation effectively Lagrangian. We have written the TESS code to solve the equations of compressible hydrodynamics and magnetohydrodynamics for both relativistic and non-relativistic fluids on a dynamic Voronoi mesh. When run in Lagrangian mode, TESS is significantly less diffusive than fixed mesh codes and thus preserves contact discontinuities to high precision while also accurately capturing strong shock waves. TESS is written for Cartesian, spherical, and cylindrical coordinates and is modular so that auxiliary physics solvers are readily integrated into the TESS framework and so that this can be readily adapted to solve general systems of equations. We present results from a series of test problems to demonstrate the performance of TESS and to highlight some of the advantages of the dynamic tessellation method for solving challenging problems in astrophysical fluid dynamics.

  2. Measurements of radial profiles of ion cyclotron resonance heating on the Tandem Mirror Experiment-Upgrade

    Energy Technology Data Exchange (ETDEWEB)

    Falabella, S.

    1988-05-11

    A small Radial Energy Analyzer (REA) was used on the Tandem Mirror Experiment-Upgrade (TMX-U), at Lawerence Livermore National Laboratory, to investigate the radial profiles of ion temperature, density, and plasma potential during Ion Cyclotron Resonance Heating (ICRH). The probe has been inserted into the central-cell plasma at temperatures of 200 eV and densities of 3 x 10/sup 12/cm/sup /minus 3// without damage to the probe, or major degradation of the plasma. This analyzer has indicated an increase in ion temperature from near 20 eV before ICRH to near 150 eV during ICRH, with about 60 kW of broadcast power. The REA measurements were cross-checked against other diagnostics on TMX-U and found to be consistent. The ion density measurement was compared to the line-density measured by microwave interferometry and found to agree within 10 to 20%. A radial intergral of n/sub i/T/sub i/ as measured by the REA shows good agreement with the diamagnetic loop measurement of plasma energy. The radial density profile is observed to broaden during the RF heating pulses, without inducing additional radial losses in the core plasma. The radial profile of plasma is seen to vary from axially peaked, to nearly flat as the plasma conditions carried over the series of experiments. To relate the increase in ion temperature to power absorbed by the plasma, a power balance as a function of radius was performed. The RF power absorbed is set equal to the sum of the losses during ICRH, minus those without ICRH. This method accounts for more than 70% of the broadcast power using a simple power balance model. The measured radial profile of the RF heating was compared to the calculations of two codes, ANTENA and GARFIELD, to test their effectiveness as predictors of power absorption profiles for TMX-U. 62 refs., 63 figs., 7 tabs.

  3. Measurements of radial profiles of ion cyclotron resonance heating on the Tandem Mirror Experiment-Upgrade

    International Nuclear Information System (INIS)

    Falabella, S.

    1988-01-01

    A small Radial Energy Analyzer (REA) was used on the Tandem Mirror Experiment-Upgrade (TMX-U), at Lawerence Livermore National Laboratory, to investigate the radial profiles of ion temperature, density, and plasma potential during Ion Cyclotron Resonance Heating (ICRH). The probe has been inserted into the central-cell plasma at temperatures of 200 eV and densities of 3 x 10 12 cm/sup /minus 3// without damage to the probe, or major degradation of the plasma. This analyzer has indicated an increase in ion temperature from near 20 eV before ICRH to near 150 eV during ICRH, with about 60 kW of broadcast power. The REA measurements were cross-checked against other diagnostics on TMX-U and found to be consistent. The ion density measurement was compared to the line-density measured by microwave interferometry and found to agree within 10 to 20%. A radial intergral of n/sub i/T/sub i/ as measured by the REA shows good agreement with the diamagnetic loop measurement of plasma energy. The radial density profile is observed to broaden during the RF heating pulses, without inducing additional radial losses in the core plasma. The radial profile of plasma is seen to vary from axially peaked, to nearly flat as the plasma conditions carried over the series of experiments. To relate the increase in ion temperature to power absorbed by the plasma, a power balance as a function of radius was performed. The RF power absorbed is set equal to the sum of the losses during ICRH, minus those without ICRH. This method accounts for more than 70% of the broadcast power using a simple power balance model. The measured radial profile of the RF heating was compared to the calculations of two codes, ANTENA and GARFIELD, to test their effectiveness as predictors of power absorption profiles for TMX-U. 62 refs., 63 figs., 7 tabs

  4. Measurements of radial profiles of ion cyclotron resonance heating on the tandem mirror experiment

    International Nuclear Information System (INIS)

    Falabella, S.

    1988-01-01

    A small Radial Energy Analyzer (REA) was used on the Tandem Mirror Experiment-Upgrade (TMX-U), at Lawrence Livermore National Laboratory, to investigate the radial profiles of ion temperature, density, and plasma potential during Ion Cyclotron Resonance Heating (ICRH). This analyzer indicates an increase in ion temperature from ∼20 eV before ICRH to ∼150 eV during ICRH, with ∼60 kW of broadcast power. The REA measurements were cross-checked against other diagnostics on TMX-U and found to be consistent. The ion density measurement was compared to the line-density measured by microwave interferometry and found to agree within 10 to 20%. A radial integral of n i T i as measured by the REA shows good agreement with the diamagnetic loop measurement of plasma energy. The radial density profile is observed to broaden during the RF heating pulses, without inducing additional radial losses in the core plasma. The radial profile of plasma potential is seen to vary from axially peaked, to nearly flat, as the plasma conditions varied over the series of experiments. To relate the increase in ion temperature to power absorbed by the plasma, a power balance as a function of radius was performed. The RF power absorbed is set equal to the sum of the losses during ICRH, minus those without ICRH. This method accounts for more than 70% of the broadcast power using a simple power balance model. The measured radial profile of the RF heating was compared to the calculations of two codes, ANTENA and GARFIELD, to test their effectiveness as predictors of power absorption profiles for TMX-U

  5. Reanalyzing the Characteristics of Modern Feminism in Tess of the D’Urb-ervilles

    Institute of Scientific and Technical Information of China (English)

    ZHANG Chun-yan

    2015-01-01

    This paper mainly focuses on the hero Tess, a beautiful, hardworking, sweet-natured and innocent girl. As the outstand⁃ing pioneer of the Feminists, Tess embodies the typical characteristics of the modern women:hardworking, brave, responsible and independent. Tess is not only a person who appears in the novel, but one representative of all the feminists in our modern society.

  6. Transiting Planets from Kepler, K2 & TESS

    Science.gov (United States)

    Lissauer, Jack

    2018-01-01

    NASA's Kepler spacecraft, launched in 2009, has been a resounding success. More than 4000 planet candidates have been identified using data from Kepler primary mission, which ended in 2013, and greater than 2000 of these candidates have been verified as bona fide exoplanets. After the loss of two reaction wheels ended the primary mission, the Kepler spacecraft was repurposed in 2014 to observe many fields on the sky for short periods. This new mission, dubbed K2, has led to the discovery of greater than 600 planet candidates, approximately 200 of which have been verified to date; most of these exoplanets are closer to us than the majority of exoplanets discovered by the primary Kepler mission. TESS, launching in 2018, will survey most of the sky for exoplanets, with emphasis on those orbiting nearby and/or bright host stars, making these planets especially well-suited for follow-up observations with other observatories to characterize atmospheric compositions and other properties. More than one-third of the planet candidates found by NASA's are associated with target stars that have more than one planet candidate, and such 'multis' account for the majority of candidates that have been verified as true planets. The large number of multis tells us that flat multiplanet systems like our Solar System are common. Virtually all of the candidate planetary systems are stable, as tested by numerical integrations that assume a physically motivated mass-radius relationship. Statistical studies performed on these candidate systems reveal a great deal about the architecture of planetary systems, including the typical spacing of orbits and flatness. The characteristics of several of the most interesting confirmed Kepler & K2 multi-planet systems will also be discussed.

  7. TESS Data Processing and Quick-look Pipeline

    Science.gov (United States)

    Fausnaugh, Michael; Huang, Xu; Glidden, Ana; Guerrero, Natalia; TESS Science Office

    2018-01-01

    We describe the data analysis procedures and pipelines for the Transiting Exoplanet Survey Satellite (TESS). We briefly review the processing pipeline developed and implemented by the Science Processing Operations Center (SPOC) at NASA Ames, including pixel/full-frame image calibration, photometric analysis, pre-search data conditioning, transiting planet search, and data validation. We also describe data-quality diagnostic analyses and photometric performance assessment tests. Finally, we detail a "quick-look pipeline" (QLP) that has been developed by the MIT branch of the TESS Science Office (TSO) to provide a fast and adaptable routine to search for planet candidates in the 30 minute full-frame images.

  8. Stellar activity for every TESS star in the Southern sky

    Science.gov (United States)

    Howard, Ward S.; Law, Nicholas; Fors, Octavi; Corbett, Henry T.; Ratzloff, Jeff; del Ser, Daniel

    2018-01-01

    Although TESS will search for Earths around more than 200,000 nearby stars, the life-impacting superflare occurrence of these stars remains poorly characterized. We monitor long-term stellar flare occurrence for every TESS star in the accessible sky at 2-minute cadence with the CTIO-based Evryscope, a combination of twenty-four telescopes, together giving instantaneous sky coverage of 8000 square degrees. In collaboration with Owens Valley Long Wavelength Array (LWA) all-sky monitoring, Evryscope also provides optical counterparts to radio flare, CME, and exoplanet-magnetosphere stellar activity searches. A Northern Evryscope will be installed at Mount Laguna Observatory, CA in collaboration with SDSU later this year, enabling stellar activity characterization for the full TESS target list and both continuous viewing zones, as well as providing 100% overlap with LWA radio activity. Targets of interest (e.g. Proxima Cen, TRAPPIST-1) are given special focus. We are currently sensitive to stellar activity down to 1% precision at g' ~ 10 and about 0.2 of a magnitude at g' ~ 15. With 2-minute cadence and a projected 5-year timeline, with 2+ years already recorded, we present preliminary results from an activity characterization of every Southern TESS target.

  9. Redefinition of the Position of Women in Osonye Tess Onwueme's ...

    African Journals Online (AJOL)

    Tess Onwueme is a Nigerian female playwright who is devoted to changing the position of women in her society, as her plays depicts. The Reign of Wazobia is one of such plays. The play portrays the story of women around a female character 'Wazobia' who rebels against the customs of her people. She articulates concern ...

  10. Travelling Theory The Feminism and Womanism of Tess Onwueme ...

    African Journals Online (AJOL)

    Osonye Tess Onwueme is arguably the leading female Nigerian dramatist today within and outside the country. Since leaving Nigeria for the United States, she seems to have acquired a deeper orientation of the concept and theory of feminism, especially feminism as praxis. The totality of her plays since A Hen too Soon ...

  11. Status of the TESS Science Processing Operations Center

    Science.gov (United States)

    Jenkins, Jon M.; Twicken, Joseph D.; Campbell, Jennifer; Tenebaum, Peter; Sanderfer, Dwight; Davies, Misty D.; Smith, Jeffrey C.; Morris, Rob; Mansouri-Samani, Masoud; Girouardi, Forrest; hide

    2017-01-01

    The Transiting Exoplanet Survey Satellite (TESS) science pipeline is being developed by the Science Processing Operations Center (SPOC) at NASA Ames Research Center based on the highly successful Kepler Mission science pipeline. Like the Kepler pipeline, the TESS science pipeline will provide calibrated pixels, simple and systematic error-corrected aperture photometry, and centroid locations for all 200,000+ target stars, observed over the 2-year mission, along with associated uncertainties. The pixel and light curve products are modeled on the Kepler archive products and will be archived to the Mikulski Archive for Space Telescopes (MAST). In addition to the nominal science data, the 30-minute Full Frame Images (FFIs) simultaneously collected by TESS will also be calibrated by the SPOC and archived at MAST. The TESS pipeline will search through all light curves for evidence of transits that occur when a planet crosses the disk of its host star. The Data Validation pipeline will generate a suite of diagnostic metrics for each transit-like signature discovered, and extract planetary parameters by fitting a limb-darkened transit model to each potential planetary signature. The results of the transit search will be modeled on the Kepler transit search products (tabulated numerical results, time series products, and pdf reports) all of which will be archived to MAST.

  12. Trajectory Design for the Transiting Exoplanet Survey Satellite (TESS)

    Science.gov (United States)

    Dichmann, Donald J.; Parker, Joel; Williams, Trevor; Mendelsohn, Chad

    2014-01-01

    The Transiting Exoplanet Survey Satellite (TESS) is a National Aeronautics and Space Administration (NASA) mission launching in 2017. TESS will travel in a highly eccentric orbit around Earth, with initial perigee radius near 17 Earth radii (Re) and apogee radius near 59 Re. The orbit period is near 2:1 resonance with the Moon, with apogee nearly 90 degrees out-of-phase with the Moon, in a configuration that has been shown to be operationally stable. TESS will execute phasing loops followed by a lunar flyby, with a final maneuver to achieve 2:1 resonance with the Moon. The goals of a resonant orbit with long-term stability, short eclipses and limited oscillations of perigee present significant challenges to the trajectory design. To rapidly assess launch opportunities, we adapted the SWM76 launch window tool to assess the TESS mission constraints. To understand the long-term dynamics of such a resonant orbit in the Earth-Moon system we employed Dynamical Systems Theory in the Circular Restricted 3-Body Problem (CR3BP). For precise trajectory analysis we use a high-fidelity model and multiple shooting in the General Mission Analysis Tool (GMAT) to optimize the maneuver delta-V and meet mission constraints. Finally we describe how the techniques we have developed can be applied to missions with similar requirements.

  13. Machine and plasma diagnostic instrumentation systems for the Tandem Mirror Experiment Upgrade

    International Nuclear Information System (INIS)

    Coutts, G.W.; Coffield, F.E.; Lang, D.D.; Hornady, R.S.

    1981-01-01

    To evaluate performance of a second generation Tandem Mirror Machine, an extensive instrumentation system is being designed and installed as part of the major device fabrication. The systems listed will be operational during the start-up phase of the TMX Upgrade machine and provide bench marks for future performance data. In addition to plasma diagnostic instrumentation, machine parameter monitoring systems will be installed prior to machine operation. Simultaneous recording of machine parameters will permit evaluation of plasma parameters sensitive to machine conditions

  14. Development of procedures to ensure quality and integrity in Tandem Mirror Experiment-Upgrade (TMX-U) diagnostics systems

    International Nuclear Information System (INIS)

    Coutts, G.W.; Coon, M.L.; Hinz, A.F.; Hornady, R.S.; Lang, D.D.; Lund, N.P.

    1983-01-01

    The diagnostic systems for Tandem Mirror Experiment-Upgrade (TMX-U) have grown from eleven initial systems to more than twenty systems. During operation, diagnostic system modifications are sometimes required to complete experimental objectives. Also, during operations new diagnostic systems are being developed and implemented. To ensure and maintain the quality and integrity of the data signals, a set of plans and systematic actions are being developed. This paper reviews the procedures set in place to maintain the integrity of existing data systems and ensure the performance objectives of new diagnostics being added

  15. Operational experience with compressed geometry acceleration tubes in the Oak Ridge 25URC tandem accelerator

    International Nuclear Information System (INIS)

    Jones, C.M.; Haynes, D.L.; Juras, R.C.; Meigs, M.J.; Ziegler, N.F.

    1989-01-01

    Installation of compressed geometry acceleration tubes and other associated modifications have increased the effective voltage capability of the Oak Ridge 25URC tandem accelerator by about 3 MV. Since mid-September 1988, the accelerator has been operated routinely at terminal potentials up to 24 MV and occasionally near 25 MV. In 3500 hours of full-column operation, including 1100 hours at potentials about 22 MV, no significant spark-included damage was observed. Some considerations related to further improvements in voltage performance are discussed. 7 refs., 5 figs

  16. Gas pressure measurements and control in the Tara tandem mirror experiment

    International Nuclear Information System (INIS)

    Post, R.S.; Brau, K.; Casey, J.

    1986-05-01

    The Tara Tandem Mirror has a 10 m long, 22 cm diameter central cell plasma heated by fundamental ion cyclotron heating. Typical central cell parameters in unplugged operation are n = 3 x 10 12 /cm 3 . T/sub i perpendicular/ = 300 eV, T/sub i parallel/ ≅ 75 eV. The axisymmetric plug cell incorporates sloshing ions and ECH to generate axial confining potentials. The axisymmetric central cell and plug comprise a max-B mirror which is observed to operate in both flute stable and unstable regimes. The flute instability is m = 1 and can be stabilized by an outboard anchor. The anchor plasma is formed by electron and ion cyclotron heating. Satisfactory operation of a tandem mirror requires extensive control of neutral gas from neutral beam (NB) sources and startup. Tara makes extensive use of Ti gettering in the beamlines, beam dumps and plasma surfaces for both hydrogen pumping and reflux control. A description of this technology along with its impact on plasma performance is discussed

  17. Ion cyclotron radio frequency systems and performance on the tandem mirror experiment-upgrade (TMX-U)

    International Nuclear Information System (INIS)

    Moore, T.L.; Molvik, A.W.; Cummins, W.F.; Pedrotti, L.R.; Henderson, A.L.; Karsner, P.G.; Scofield, D.W.; Brooksby, C.A.

    1983-01-01

    High power ion cyclotron radio frequency (ICRF) systems are now gaining greater attention than before as prime driver ion heating systems. Lawrence Livermore National Laboratory (LLNL) has installed a 200 kW high frequency (HF) transmitter system on its Tandem Mirror Experiment-Upgrade (TMX-U). This paper describes the system, antenna, controls, and monitoring apparatus. The transmitter operates into a high Q antenna installed in the central cell region of the experiment. It incorporates a dual-port feedback system to automatically adjust the transmitter's output power and allow the maximum consistent with the plasma loading of the antenna. Special techniques have been used to measure, in real-time, the dynamically changing loading values presented by the plasma. From the measurements, the antenna impedance can be optimized for specified plasma density

  18. TESS-based dose-response using pediatric clonidine exposures

    International Nuclear Information System (INIS)

    Benson, Blaine E.; Spyker, Daniel A.; Troutman, William G.; Watson, William A.

    2006-01-01

    Objective: The toxic and lethal doses of clonidine in children are unclear. This study was designed to determine whether data from the American Association of Poison Control Centers Toxic Exposure Surveillance System (TESS) could be utilized to determine a dose-response relationship for pediatric clonidine exposure. Methods: 3458 single-substance clonidine exposures in children <6 years of age reported to TESS from January 2000 through December 2003 were examined. Dose ingested, age, and medical outcome were available for 1550 cases. Respiratory arrest cases (n = 8) were classified as the most severe of the medical outcome categories (Arrest, Major, Moderate, Mild, and No effect). Exposures reported as a 'taste or lick' (n = 51) were included as a dose of 1/10 of the dosage form involved. Dose ranged from 0.4 to 1980 (median 13) μg/kg. Weight was imputed based on a quadratic estimate of weight for age. Dose certainty was coded as exact (26% of cases) or not exact (74%). Medical outcome (response) was examined via logistic regression using SAS JMP (release 5.1). Results: The logistic model describing medical outcome (P < 0.0001) included Log dose/kg (P 0.0000) and Certainty (P = 0.045). Conclusion: TESS data can provide the basis for a statistically sound description of dose-response for pediatric clonidine poisoning exposures

  19. TESS-based dose-response using pediatric clonidine exposures.

    Science.gov (United States)

    Benson, Blaine E; Spyker, Daniel A; Troutman, William G; Watson, William A

    2006-06-01

    The toxic and lethal doses of clonidine in children are unclear. This study was designed to determine whether data from the American Association of Poison Control Centers Toxic Exposure Surveillance System (TESS) could be utilized to determine a dose-response relationship for pediatric clonidine exposure. 3,458 single-substance clonidine exposures in children TESS from January 2000 through December 2003 were examined. Dose ingested, age, and medical outcome were available for 1550 cases. Respiratory arrest cases (n = 8) were classified as the most severe of the medical outcome categories (Arrest, Major, Moderate, Mild, and No effect). Exposures reported as a "taste or lick" (n = 51) were included as a dose of 1/10 of the dosage form involved. Dose ranged from 0.4 to 1980 (median 13) microg/kg. Weight was imputed based on a quadratic estimate of weight for age. Dose certainty was coded as exact (26% of cases) or not exact (74%). Medical outcome (response) was examined via logistic regression using SAS JMP (release 5.1). The logistic model describing medical outcome (P TESS data can provide the basis for a statistically sound description of dose-response for pediatric clonidine poisoning exposures.

  20. ICRF experiments and potential formation on the GAMMA 10 tandem mirror

    International Nuclear Information System (INIS)

    Ichimura, M.; Cho, T.; Higaki, H.

    2005-01-01

    Target plasmas, on which the formation of the electrostatic potentials and the improvement of the confinement are studied, are produced with ICRF in the GAMMA 10 tandem mirror. The ion temperature of more than 10 keV has been achieved in relatively low density plasmas. When the strong ICRF heating is applied, it is observed that the high frequency and the low frequency fluctuations are excited and suppress the increase in the plasma parameters. Recently, a new high power gyrotron system has been constructed and the plug ECRH power extends up to 370 kW. The improvement of the confinement due to the formation of the potential in the axial direction and the strong radial electric field shear has been observed. (author)

  1. Utilizing subcooled, superfluid He-II in the design of a 12-Tesla tandem mirror experiment

    International Nuclear Information System (INIS)

    Hoard, R.W.; Cornish, D.N.; Baldi, R.W.; Taylor, W.D.

    1981-01-01

    A design study of 12-T yin-yang coils for a conceptual Tandem Mirror Next Step facility has been recently performed by Lawrence Livermore National Laboratory in conjunction with the Convair Division of General Dynamics. The large magnets have major and mirror radii of 3.7 and 1.5 m, 0.70 x 3.75 m 2 cross section, 46.3 MA turns, and an overall current density of 1765 A/cm 2 , obtained by the use of Nb 3 Sn and Nb-Ti superconductors. Each coil is composed of several subcoils separated by internal strengthening substructure to react the enormous electromagnetic forces. The size of the yin-yang coils, and hence the current density, was reduced by utilizing subcooled, superfluid He-II at 1.8 K for the coolant. This paper reviews the design study, with emphasis on He-II heat transport and conductor stability. Methods are also presented which allow the extension of Gorter-Mellink-channel calculations to encompass multiple, interconnecting coolant channels

  2. Contemporary Interpretations of "Tess of the d'Urbervilles": Implications for the Classroom.

    Science.gov (United States)

    Edwards, Suzanne O.

    Because of its wide range of justifiable interpretations, Thomas Hardy's "Tess of the d'Urbervilles" is an appropriate novel to use to help students become better critical readers. Scholarly criticism continues to debate the topic of Tess's character, yet recent feminist and deconstructionist approaches, as well as recently published…

  3. On the detectability of solar-like oscillations with the NASA TESS mission

    Science.gov (United States)

    Campante, Tiago L.

    2017-10-01

    The upcoming NASA TESS mission will perform an all-sky survey for planets transiting bright nearby stars. In addition, its excellent photometric precision will enable asteroseismology of solar-type and red-giant stars. We apply a newly developed detection test along a sequence of stellar evolutionary tracks in order to predict the detectability of solar-like oscillations with TESS.

  4. Do Students Share the Same Experience in an Online Language Exchange Programme?--The Chinese-French eTandem Case

    Science.gov (United States)

    Szilas, Jue Wang; Zhang, Ling; Berger, Claudia

    2013-01-01

    This article presents the findings of an eTandem Chinese-French exchange course during two academic years, the year 2010-2011 when the course was not credited, and the year 2011-2012 when the course was credited in one university but not in the other. It focuses on the students' perspective about the language exchange experience. The participants…

  5. The operational experience with 15 UD Pelletron tandem accelerator and its status

    International Nuclear Information System (INIS)

    Joshi, R.; Singh, J.; Singh, P.

    2015-01-01

    IUAC, New Delhi is equipped with many accelerators of different energy ranges. The 15 UD Pelletron tandem accelerator, the first ion accelerator installed, is a heavy ion accelerator and can accelerate almost all the injected negative ions. It has been operational since 1990 and is being used efficiently in different areas of research. The up time of this accelerator has always been better than 95% while the beam on target time has improved from ∼35% in earlier years to more than 60%. In these years, immense efforts have been put in for its operational improvements and better ion beam energies as well as currents. Recently a proper diagnosis was performed to improve its terminal voltage. Regular maintenance of its charging system, accelerating columns and regular unit wise conditioning have improved overall terminal voltage. The conditioning voltage of 15.5 MV was recently achieved and beam tests were performed at 15.1 MV. This has overall improved the performance of accelerator and the stable beam was delivered to user at the maximum terminal potential of 13.9 MV. The 15 UD Pelletron accelerator is also being used regularly as an injector for LINAC. Recently, few problems were encountered, in 15 UD Pelletron, during a routine LINAC operation. Those problems caused lots of beam instability and consequently beam, after boosting the energy from LINAC, was unstable. Proper investigations were carried out and necessary steps were performed in ion source and 15 UD Pelletron accelerator to overcome these problems. Thereafter, stable beam was delivered to user, using LINAC, continuously for around three months. All the efforts done to improve the performance of 15 UD Pelletron as well as to achieve stable beam from LINAC will be discussed. (author)

  6. Tandem Mirror Experiment-Upgrade neutral beam test stand: A powerful tool for development and quality assurance

    International Nuclear Information System (INIS)

    Hibbs, S.M.; Kane, R.J.; Kerr, R.G.; Poulsen, P.

    1983-01-01

    During construction of the Tandem Mirror Experiment-Upgrade (TMX-U), a test stand was assembled to develop electronics for the neutral beam system. In the first six months of test stand use the authors operated a few neutral beam injector modules and directed considerable effort toward improving the electronic system. As system development progressed, the focus turned toward improving the injector modules themselves. The test stand has proved to be the largest single contributor to the successful operation of neutral beams on TMX-U, primarily because it provides quality assurance and development capability in conjunction with the scheduled activities of the main experiment. This support falls into five major categories: (1) electronics development, (2) operator training, (3) injector module testing and characterization, (4) injector module improvements, and (5) physics improvements (through areas affected by injector operation). Normal day-to-day operation of the test stand comes under the third category, testing and characterization, and comprises the final quality assurance activity for newly assembled or repaired modules before they are installed on TMX-U. They have also used the test stand to perform a series of physics experiments, including: reducing gas flow through valve and arc chamber characterization, reducing impurities by titanium gettering, and reducing streaming gas using apertures and collisional gas dynamics

  7. Nature and Culture in Thomas Hardy's Tess of the d'Urbervilles

    Directory of Open Access Journals (Sweden)

    Elisabeth Rallo-Ditche

    2011-05-01

    Full Text Available In the 19th century, Th.Hardy’s novels offer us a surprising and remarkable example of a reflection on the relationship between Nature and Culture : he undertakes to depict a rural society – in the process of disappearing – which experiences this relationship in a mode other than that of « Naturalism » (in the sense that Philippe Descola attributes to this word, to designate our western way of considering the world which was nascent in his time. Before the anthropology of today, Th. Hardy shows precisely a different way of apprehending the world among « hodges », in a region of England in the middle of the19th century. He reveals to the reader another way of considering the relationship whith non-human beings, which is just as worthy and interesting as that of the « naturalists » of his day. The individuals he describes are aware of an inner life and of the experience of their body situated in space but they also have the possibility of understanding the link they have with the non-human beings which surround them. Tess, the main character of the novel Tess of the d’Urbervilles, is one of these individuals, she lives in harmony with Nature and shows another kind of relationship with the plant and animal world. Her social exclusion will therefore be attributable not only to the ethics of society in her time, but also to a new conception of Nature : she cannot live in this world which is becoming one of triumphant Naturalism.

  8. Tandem mirror experiment-upgrade neutral beam test stand: a powerful tool for development and quality assurance

    International Nuclear Information System (INIS)

    Hibbs, S.M.; Kane, R.J.; Kerr, R.G.; Poulsen, P.

    1983-01-01

    During construction of the Tandem Mirror Experiment-Upgrade (TMX-U), we assembled a test stand to develop electronics for the neutral beam system. In the first six months of test stand use we operated a few neutral beam injector modules and directed considerable effort toward improving the electronic system. As system development progressed, our focus turned toward improving the injector modules themselves. The test stand has proved to be the largest single contributor to the successful operation of neutral beams on TMX-U, primarily because it provides quality assurance andd development capability in conjunction with the scheduled activities of the main experiment. This support falls into five major categories: (1) electronics development, (2) operator training, (3) injector module testing and characterization, (4) injector module improvements, and (5) physics improvements (through areas affected by injector operation). Normal day-to-day operation of the test stand comes under the third category, testing and characterization, and comprises our final quality assurance activity for newly assembled or repaired modules before they are installed on TMX-U

  9. Force Limited Random Vibration Test of TESS Camera Mass Model

    Science.gov (United States)

    Karlicek, Alexandra; Hwang, James Ho-Jin; Rey, Justin J.

    2015-01-01

    The Transiting Exoplanet Survey Satellite (TESS) is a spaceborne instrument consisting of four wide field-of-view-CCD cameras dedicated to the discovery of exoplanets around the brightest stars. As part of the environmental testing campaign, force limiting was used to simulate a realistic random vibration launch environment. While the force limit vibration test method is a standard approach used at multiple institutions including Jet Propulsion Laboratory (JPL), NASA Goddard Space Flight Center (GSFC), European Space Research and Technology Center (ESTEC), and Japan Aerospace Exploration Agency (JAXA), it is still difficult to find an actual implementation process in the literature. This paper describes the step-by-step process on how the force limit method was developed and applied on the TESS camera mass model. The process description includes the design of special fixtures to mount the test article for properly installing force transducers, development of the force spectral density using the semi-empirical method, estimation of the fuzzy factor (C2) based on the mass ratio between the supporting structure and the test article, subsequent validating of the C2 factor during the vibration test, and calculation of the C.G. accelerations using the Root Mean Square (RMS) reaction force in the spectral domain and the peak reaction force in the time domain.

  10. Exploring Algorithms for Stellar Light Curves With TESS

    Science.gov (United States)

    Buzasi, Derek

    2018-01-01

    The Kepler and K2 missions have produced tens of thousands of stellar light curves, which have been used to measure rotation periods, characterize photometric activity levels, and explore phenomena such as differential rotation. The quasi-periodic nature of rotational light curves, combined with the potential presence of additional periodicities not due to rotation, complicates the analysis of these time series and makes characterization of uncertainties difficult. A variety of algorithms have been used for the extraction of rotational signals, including autocorrelation functions, discrete Fourier transforms, Lomb-Scargle periodograms, wavelet transforms, and the Hilbert-Huang transform. In addition, in the case of K2 a number of different pipelines have been used to produce initial detrended light curves from the raw image frames.In the near future, TESS photometry, particularly that deriving from the full-frame images, will dramatically further expand the number of such light curves, but details of the pipeline to be used to produce photometry from the FFIs remain under development. K2 data offers us an opportunity to explore the utility of different reduction and analysis tool combinations applied to these astrophysically important tasks. In this work, we apply a wide range of algorithms to light curves produced by a number of popular K2 pipeline products to better understand the advantages and limitations of each approach and provide guidance for the most reliable and most efficient analysis of TESS stellar data.

  11. Tandem accelerator operation and improvements

    International Nuclear Information System (INIS)

    Yang Bingfan; Zhang Canzhe; Qin Jiuchang; Hu Yueming; Zhang Guilian; Jiang Yongliang; Hou Deyi; Yang Weimin; Yang Zhiren; Su Shengyong; Kan Chaoxin; Liu Dezhong; Wang Liyong; Bao Yiwen; You Qubo; Yang Tao; Zhang Yan; Zhou Lipeng; Chai Shiqin; Wang Meiyan

    1998-01-01

    The scheduled operation of HI-13 tandem accelerator for various experiments was performed well in 1996 and 1997. The machine running time was 4600 h and 4182 h while the beam time was 3845 h and 3712 h in 1996 and 1997, respectively. The operation of HI-13 tandem accelerator is pretty well. The beam distribution with terminal voltage and the distribution of beam time with ion species are shown out. The development of accelerating tubes for HI-13 tandem is in progress

  12. Computer control of the titanium getter system on the tandem mirror experiment-upgrade (TMX-U)

    International Nuclear Information System (INIS)

    McAlice, A.J.; Bork, R.G.; Clower, C.A.; Moore, T.L.; Lang, D.D.; Pico, R.E.

    1983-01-01

    Gettering has been a standard technique for achieving high-quality vacuum in fusion experiments for some time. On Lawrence Livermore National Laboratory's Tandem Mirror Experiment (TMX-U), an extensive gettering system is utilized with liquid-nitrogen-cooled panels to provide the fast pumping during each physics experiment. The getter wires are a 85% titanium and 15% tantalum alloy directly heated by an electrical current. TMX-U has 162 getter power-supply channels; each channel supplies approximately 106 A of regulated power to each getter for a 60-s cycle. In the vacuum vessel, the getter wires are organized into poles or arrays. On each pole there are six getter wires, each cables to the exterior of the vessel. This arrangement allows the power supplies to be switched from getter wire to getter wire as the individual wires deteriorate after 200 to 300 gettering cycles. To control the getter power suppiles, we will install a computer system to operate the system and document the performance of each getter circuit. This computer system will control the 162 power supplies via a Computer Automated Measurement and Control (CAMAC) architecture with a fiber-optic serial highway. Getter wire history will be stored on the built-in 10 megabyte disc drive with new entries backed up daily on a floppy disc. Overall, this system will allow positive tracking of getter wire condition, document the total gettering performance, and predict getter maintenance/changeover cycles. How we will employ the computer system to enhance the getter system is the subject of this paper

  13. X-ray imaging studies of electron cyclotron microwave-heated plasmas in the Tandem Mirror Experiment-Upgrade

    International Nuclear Information System (INIS)

    Failor, B.H.

    1986-02-01

    An x-ray pinhole camera designed to efficiently detect photons with energies between 5 and 250 keV was built to image bremsstrahlung emission from a microwave-heated hot electron plasma. This plasma is formed at one of the thermal barrier locations in the Tandem Experiment-Upgrade at Lawrence Livermore National Laboratory. The instrument consists of a lead aperture, an x-ray converter in the form of a sodium-activated cesium iodide scintillator, light intensifier electronics, and a recording medium that may either be high speed film or a CCD array. The nominal spatial and temporal resolutions are one part in 40 and 17 msec, respectively. The component requirements for optimum performance were determined both analytically and by computer simulation, and were verified experimentally. The details of these results are presented. The instrument has been used to measure x-ray emission from the TMX-U west end cell. Data acquired with the x-ray camera has allowed us to infer the temporal evolution of the mirror-trapped electron radial profile

  14. Plasma characteristics of the end-cell of the GAMMA 10 tandem mirror for the divertor simulation experiment

    International Nuclear Information System (INIS)

    Nakashima, Y.; Sakamoto, M.; Yoshikawa, M.; Takeda, H.; Ichimura, K.; Hosoi, K.; Hirata, M.; Ichimura, M.; Ikezoe, R.; Imai, T.; Kariya, T.; Katanuma, I.; Kohagura, J.; Minami, R.; Numakura, T.; Oki, K.; Ueda, H.; Asakura, Nobuyuki; Furuta, T.; Hatayama, A.; Toma, M.; Hirooka, Y.; Masuzaki, S.; Sagara, A.; Shoji, M.; Kado, S.; Matsuura, H.; Nagata, S.; Nishino, N.; Ohno, N.; Tonegawa, A.; Ueda, Y.

    2012-11-01

    In this paper, detailed characteristics and controllability of plasmas emitted from the end-cell of the GAMMA 10 tandem mirror are described from the viewpoint of divertor simulation studies. The energy analysis of ion flux by using end-loss ion energy analyzer (ELIEA) proved that the obtained high ion temperature (100 - 400 eV) was comparable to SOL plasma parameters in toroidal devices and was controlled by changing the ICRF power. Parallel ion temperature T i∥ determined from the probe and calorimeter shows a linear relationship with the ICRF power in the central-cell and agrees with the results of ELIEA. Additional ICRF heating revealed a significant enhancement of particle flux, which indicated an effectiveness of additional plasma heating in adjacent cells toward the improvement of the performance. Superimposing the ECH pulse of 380 kW, 5 ms attained the maximum heat-flux more than 10 MW/m 2 on axis. This value comes up to the heat-load of the divertor plate of ITER, which gives a clear prospect of generating the required heat density for divertor studies by building up heating systems to the end-mirror cell. Initial results of plasma irradiation experiment and construction of new divertor module are also described. (author)

  15. E parallel B end-loss-ion analyzer for the Tandem Mirror Experiment-Upgrade (TMX-U). Revision 1

    International Nuclear Information System (INIS)

    Wood, B.E.; Foote, J.H.; Coutts, G.W.; Pedrotti, L.R.; Schlander, L.F.; Brown, M.D.

    1985-01-01

    We have installed a new diagnostic instrument to investigate ions emanating along magnetic-field lines of the TMX-U tandem-mirror experiment. This analyzer contains parallel electric and magnetic fields, which yield ion mass and energy spatial separation. A dual array of 128 copper collector plates detects particles in the ion flux that is first collimated and then focused through the 180-degree bending magnetic field. An electric field applied transverse to the bending particle path then separates the ion masses in the direction perpendicular to the magnetic-pole faces while the magnetic field spreads out the different energies of each mass in a plane parallel to the magnetic-pole tips. The CAMAC-based data recorders are fiber-optically coupled to the system controller for data acquisition, analysis, and display. A commercial CAMAC data recorder was modified for current input. We expect to measure higher particle energies than the present gridded end-loss analyzers as well as to more accurately determine the energy spectra

  16. An x-ray detection system development for Tandem Mirror Experiment Upgrade (TMX-U): Hardware and software

    International Nuclear Information System (INIS)

    Jones, R.M.; Coutts, G.W.; Failor, B.H.

    1983-01-01

    This x-ray detection system measures the electron Bremstrahlung spectrum from the Tandem Mirror Experiment-Upgrade (TMX-U). From this spectrum, we can calculate the electron temperature. The low energy portion of the spectrum (0.5-40 keV) is measured by a liquid-nitrogen-cooled, lithium-drifted silicon detector. The higher energy spectrometer uses an intrinsic germanium detector to accommodate the 100 to 200 keV spectra. The system proceeds as follows. The preamplified detector signals are digitized by a high-speed A-to-D converter located in a Computer Automated Measurement and Control (CAMAC) crate. The data is then stored in a histogramming memory via a data router. The CAMAC crate interfaces with a local desktop computer or the main data acquisition computer that stores the data. The software sets up the modules, acquires the energy spectra (with sample times as short as 2 ms) and plots it. Up to 40 time-resolved spectra are available during one plasma cycle. The actual module configuration, CAMAC interfacing and software that runs the system are the subjects of this paper

  17. Design and fabrication of circular and rectangular components for electron-cyclotron-resonant heating of tandem mirror experiment-upgrade

    International Nuclear Information System (INIS)

    Felker, B.; Calderon, M.O.; Chargin, A.K.

    1983-01-01

    The electron-cyclotron-resonant heating (ECRH) systems of rectangular waveguides on Tandem Mirror Experiment-Upgrade (TMX-U) operated with a overall efficiency of 50%, each system using a 28-GHz, 200-kW pulsed gyrotron. We designed and built four circular-waveguide systems with greater efficiency and greater power-handling capabilities to replace the rectangular waveguides. Two of these circular systems, at the 5-kG second-harmonic heating locations, have a total transmission efficiency of >90%. The two systems at the 10-kG fundamental heating locations have a total transmission efficiency of 80%. The difference in efficiency is due to the additional components required to launch the microwaves in the desired orientation and polarization with respect to magnetic-field lines at the 10-kG points. These systems handle the total power available from each gyrotron but do not have the arcing limitation problem of the rectangular waveguide. Each system requires several complex components. The overall physical layout and the design considerations for the rectangular and circular waveguide components are described here

  18. Design and fabrication of circular and rectangular components for electron-cyclotron-resonant heating of tandem mirror experiment-upgrade

    Energy Technology Data Exchange (ETDEWEB)

    Felker, B.; Calderon, M.O.; Chargin, A.K.; Coffield, F.E.; Lang, D.D.; Rubert, R.R.; Pedrotti, L.R.; Stallard, B.W.; Gallagher, N.C. Jr.; Sweeney, D.W.

    1983-11-18

    The electron-cyclotron-resonant heating (ECRH) systems of rectangular waveguides on Tandem Mirror Experiment-Upgrade (TMX-U) operated with a overall efficiency of 50%, each system using a 28-GHz, 200-kW pulsed gyrotron. We designed and built four circular-waveguide systems with greater efficiency and greater power-handling capabilities to replace the rectangular waveguides. Two of these circular systems, at the 5-kG second-harmonic heating locations, have a total transmission efficiency of >90%. The two systems at the 10-kG fundamental heating locations have a total transmission efficiency of 80%. The difference in efficiency is due to the additional components required to launch the microwaves in the desired orientation and polarization with respect to magnetic-field lines at the 10-kG points. These systems handle the total power available from each gyrotron but do not have the arcing limitation problem of the rectangular waveguide. Each system requires several complex components. The overall physical layout and the design considerations for the rectangular and circular waveguide components are described here.

  19. The tandem mirror experiment upgrade (TMX-U) diagnostics data system

    International Nuclear Information System (INIS)

    Clauser, J.F.; Parrish, C.P.

    1983-01-01

    The diagnostics data system on the TMX-U experiment is a general purpose system for handling acquisition, processing, archiving, interactive selection and retrieval, and graphical and tabular outputting of data for pulsed controlled thermonuclear reaction experiments. It routinely acquires and processes three MBytes of data per shot at an average shot rate of one per 8 minutes. The computer hardware consists of five CPUs in a star configuration with approximately 500 MBytes of disk storage at the central node, upon which all CPUs may read and write. The use of several CPUs in parallel increases computing power, while the use of eight disk drives in parallel increases disk speed. All processing, outputting, and acquisition are performed by program modules that allow chained operations, i.e., the inputs for a given task (program execution) are the output(s) of a previous task or tasks. Inputs may be any data-set on disk. Tasks for various shots may overlap so that high priority results are immediately available, while low priority results may backlog and catch up during lulls in experiment operation. Task selection is thus both data-availability and priority driven. It is done in a distributed fashion, independently by each of the five CPUs (not master-slave). A given task will run on any available, suitable CPU. CPU suitability is determined using a device resource control system. Program resource requirements, task definitions, task lists, etc., as well as permanent definitions of all archived data-set configurations and symbols are saved using a commercial data-base system and custom editor, which form a data-system ''notebook''. The actual data are held in a custom data base with a hybrid relational/hierarchical form. Data-set formats are selectable from a rich, yet standardized set that can accommodate a large variety of acquired or calculated data

  20. Thermal barrier confinement experiments in TMX-U tandem mirror. Revision 1

    International Nuclear Information System (INIS)

    Simonen, T.C.; Allen, S.L.; Baldwin, D.E.

    1984-01-01

    In our recent experiments on the TMX-U thermal-barrier device, we achieved the end plugging of axial ion losses up to a central cell density of n/sub c/ = 6 x 10 12 cm -3 . During lower density experiments, we measured the axial potential profile characteristic of a thermal barrier and found an ion-confining potential greater than 1.5 kV and a potential depression of 0.45 kV in the barrier region. The average beta of hot end plug electrons has reached 15% and of hot central cell ions has reached 6%. In addition, we heated deuterium ions in the central cell with ICRF to an average perpendicular energy of 2 keV. During strong end plugging at low density (7 x 10 11 cm -3 ), the axial ion confinement time tau/sub parallel to/ reached 50 to 100 ms while the nonambiopolar radial ion confinement time tau/sub perpendicular to/ was 14 ms - independent of end plugging. Electrically floating end walls doubled the radial ion confinement time. At higher densities and lower potentials, tau/sub parallel to/ was 6 to 12 ms and tau/sub perpendicular to/ exceeded 100 ms

  1. Titanium sublimation pumping systems and performances on the Tandem Mirror Experiment-Upgrade (TMX-U)

    International Nuclear Information System (INIS)

    Pico, R.E.

    1986-01-01

    This paper presents a brief history of the TMX-U Titanium Sublimation Pumping process (gettering). Titanium sublimation pumps offer an economical means of pumping chemically active gases (especially hydrogen) at high speeds, and serves as additional pumps, along with liquid nitrogen-cooled panels, to provide pumping during each physics experiment. Because of the size of the system, a complex computer program was written which is run-time compiled, and then run by the computer. With the multi-tasking capability of the computer, five programs are used in operation and run simultaneously. All getter wire history, deposition, and system notes are stored on the external disc drive. The progress and performance in the four years the system has been used, two year manually controlled, and two computer controlled with be covered. Emphasis on the computer control system and its by-products, which enhance the operation of the TMX-U, will be the subject of this paper

  2. MHD stability of tandem mirrors

    International Nuclear Information System (INIS)

    Poulsen, P.; Molvik, A.; Shearer, J.

    1982-01-01

    The TMX-Upgrade experiment was described, and the manner in which various plasma parameters could be affected was discussed. The initial analysis of the MHD stability of the tandem mirror was also discussed, with emphasis on the negative tandem configuration

  3. Recent experimental progress in the TMX-U thermal barrier tandem mirror experiment

    International Nuclear Information System (INIS)

    Turner, W.C.; Allen, S.L.; Casper, T.A.

    1984-01-01

    Recent experiments on the TMX-U thermal barrier device at LLNL have achieved the end plugging of axial ion losses up to a central cell density of n/sub c/ = 2 x 10 12 cm. During these tests, the axial potential profile characteristic of a thermal barrier has been measured experimentally, indicating an ion-confining potential greater than 1.5 kV and a potential depression of 0.45 kV in the barrier region. The average beta of hot electrons in the thermal barrier has been increased to 15% and appears limited only by classical scattering and ECRH pulse duration. Furthermore, deuterium ions in the central cell have been heated with ICRF to an average energy of 1.5 keV, with a heating efficiency of 40%. During strong end plugging, the axial ion confinement time reached 50 to 100 ms while the nonambipolar radial ion confinement time was 5 to 15 ms - independent of end plugging. Radial ion confinement time exceeding 100 ms has been attained on shots without end plugging. Plates, floated electrically on the end walls, have increased the radial ion confinement time by a factor of 1.8. Further improvement in the central cell density during end plugging can be expected by increasing the ICRF, improving the central cell vacuum conditions and beam heating efficiency, and increasing the radial extent of the potential control plates on the end walls

  4. Precision Stellar and Planetary Astrophysics with TESS and Gaia

    Science.gov (United States)

    Stevens, Daniel J.; KELT Collaboration

    2018-01-01

    There is an ever-present need for precise and accurate stellar parameters, particularly for low-mass stars. For example, some fraction of measured M dwarf radii are inflated and have effective temperatures that are suppressed relative to predictions from models, but the physical cause of these effects is still uncertain. This is exacerbated by the fact that only a handful of M dwarfs -- all from double-lined eclipsing binaries (EBs) -- have both masses and radii measured to 3% or better. In the Gaia era, we can now measure model-independent masses and radii for single-lined EBs, thus expanding the sample of stars with precisely measured parameters by at least an order of magnitude, in principle. I will illustrate how one can combine Gaia parallaxes and broad-band stellar fluxes with the eclipse and radial velocity data to provide model-independent masses and radii. I will present our expected achievable constraints on the masses and radii of single-lined EBs. I will discuss both our current effort to turn several dozens of single-lined EBs discovered by the KELT and HATNet surveys into a catalog of exquisitely characterized stars and exoplanets as well as the prospects for achieving similar science for a much larger number of systems with TESS.

  5. (ReViewing Maggie and Tess through the Lens of Standpoint Theory

    Directory of Open Access Journals (Sweden)

    Sardar M Anwaruddin

    2013-03-01

    Full Text Available Literary critics admire George Eliot's touching portrayal of Maggie Tulliver in The Mill on the Floss. Many readers prefer to read Maggie's character as a reworking of Eliot's own life. In this article, I compare Maggie with another famous literary heroine, Tess Durbeyfield of Thomas Hardy's Tess of the D'Urbervilles. Tess is a "low-born" country girl whose suffering begins as soon as her family discovers that they have noble connections. Both Maggie and Tess go through hardship and humiliation due to their sense of responsibility and commitment to do the best for their families. Looking at these two characters through the lens of feminist standpoint theory, I argue that Maggie and Tess' social locations, imposed gender-roles, and families' expectations are among the primary causes of their tragedy. As members of the oppressed (gender group, their epistemologies to understand the reality and to make sense of their social relationships contradict with those of the dominant group-masculine.

  6. Potential measurements in tandem mirrors

    International Nuclear Information System (INIS)

    Glowienka, J.C.

    1985-11-01

    The US mirror program has begun conducting experiments with a thermal barrier tandem mirror configuration. This configuration requires a specific axial potential profile and implies measurements of potential for documentation and optimization of the configuration. This report briefly outlines the motivation for the thermal barrier tandem mirror and then outlines the techniques used to document the potential profile in conventional and thermal barrier tandem mirrors. Examples of typical data sets from the world's major tandem mirror experiments, TMX and TMX-U at Lawrence Livermore National Laboratory (LLNL) and Gamma 10 at Tsukuba University in Japan, and the current interpretation of the data are discussed together with plans for the future improvement of measurements of plasma potential

  7. In Search of Stellar Music: Finding Pulsators for the TESS Mission

    Science.gov (United States)

    Richey-Yowell, Tyler; Pepper, Joshua; KELT Collaboration

    2017-01-01

    The Transiting Exoplanet Survey Satellite (TESS) will search for small transiting exoplanets orbiting bright stars. One of the additional mission objectives is to observe oscillating variable stars to precisely measure these stars’ masses, radii, and internal structures. Since TESS can observe only a limited number of stars with high enough cadence to detect these oscillations, it is necessary to identify candidates that will yield the most valuable results. Using data from the Kilodegree Extremely Little Telescope (KELT), we searched for bright stars showing oscillations to be included as TESS targets. We found 2,108 variable stars with B-V < 0.5 and P < 5 days. Further analysis will be carried out to establish final candidates. This project was funded by the National Science Foundation grant PHY-1359195 to the Lehigh University REU program.

  8. Note: Establishing α-particle radiation damage experiments using the Dalton Cumbrian Facility's 5 MV tandem pelletron

    Science.gov (United States)

    Bower, W. R.; Smith, A. D.; Pattrick, R. A. D.; Pimblott, S. M.

    2015-04-01

    Evaluating the radiation stability of mineral phases is a vital research challenge when assessing the performance of the materials employed in a Geological Disposal Facility for radioactive waste. This report outlines the setup and methodology for efficiently allowing the determination of the dose dependence of damage to a mineral from a single ion irradiated sample. The technique has been deployed using the Dalton Cumbrian Facility's 5 MV tandem pelletron to irradiate a suite of minerals with a controlled α-particle (4He2+) beam. Such minerals are proxies for near-field clay based buffer material surrounding radioactive canisters, as well as the sorbent components of the host rock.

  9. Characterization and Validation of Transiting Planets in the TESS SPOC Pipeline

    Science.gov (United States)

    Twicken, Joseph D.; Caldwell, Douglas A.; Davies, Misty; Jenkins, Jon Michael; Li, Jie; Morris, Robert L.; Rose, Mark; Smith, Jeffrey C.; Tenenbaum, Peter; Ting, Eric; Wohler, Bill

    2018-06-01

    Light curves for Transiting Exoplanet Survey Satellite (TESS) target stars will be extracted and searched for transiting planet signatures in the Science Processing Operations Center (SPOC) Science Pipeline at NASA Ames Research Center. Targets for which the transiting planet detection threshold is exceeded will be processed in the Data Validation (DV) component of the Pipeline. The primary functions of DV are to (1) characterize planets identified in the transiting planet search, (2) search for additional transiting planet signatures in light curves after modeled transit signatures have been removed, and (3) perform a comprehensive suite of diagnostic tests to aid in discrimination between true transiting planets and false positive detections. DV data products include extensive reports by target, one-page summaries by planet candidate, and tabulated transit model fit and diagnostic test results. DV products may be employed by humans and automated systems to vet planet candidates identified in the Pipeline. TESS will launch in 2018 and survey the full sky for transiting exoplanets over a period of two years. The SPOC pipeline was ported from the Kepler Science Operations Center (SOC) codebase and extended for TESS after the mission was selected for flight in the NASA Astrophysics Explorer program. We describe the Data Validation component of the SPOC Pipeline. The diagnostic tests exploit the flux (i.e., light curve) and pixel time series associated with each target to support the determination of the origin of each purported transiting planet signature. We also highlight the differences between the DV components for Kepler and TESS. Candidate planet detections and data products will be delivered to the Mikulski Archive for Space Telescopes (MAST); the MAST URL is archive.stsci.edu/tess. Funding for the TESS Mission has been provided by the NASA Science Mission Directorate.

  10. Transit Precovery: Determining Ephemerides for Long-Period TESS Detections with KELT Photometry

    Science.gov (United States)

    Yao, Xinyu; Pepper, Joshua; KELT Collaboration

    2018-01-01

    The majority of the known exoplanets were discovered by using the transit method such as with Kepler and the upcoming TESS mission. Unlike the Kepler mission which observed stars for several years, 74% of the area to be observed by TESS will only have an observational baseline of 27 days. For those planets with periods longer than 13 days, TESS can only capture one or two transits which means the true ephemerides are difficult to determine. Since the ground based all sky survey project KELT has much longer observation baseline (up to ten years) and monitors fields that overlap with TESS fields, by using KELT photometric data the ephemerides of the single and double-transit events that will be detected by TESS can be determined precisely. By conducting a simulation process to insert transits into KELT light curves and recover periods, we find that KELT photometry can be used to confirm ephemerides with high accuracy for planets of Neptune size or larger with orbital periods as long as a year, and therefore across a wide range of planet equilibrium temperatures. The resulting periods of the signals can then be used by follow-up teams, whether part of the TESS mission or the community-organized TFOP project, to plan and coordinate follow-up observations to confirm these cases as planets, eclipsing binaries, or other false positives, as well as conduct detailed transit observations with facilities like JWST or HST.This project makes use of data from the KELT survey, including support from The Ohio State University, Vanderbilt University, and Lehigh University.

  11. First results from a 1-D imaging spectrometer using Ir TESs

    Energy Technology Data Exchange (ETDEWEB)

    Smith, S.J.Stephen J. E-mail: sts@star.le.ac.uk; Whitford, Chris; Fraser, George W.; Holland, Andrew D.; Goldie, David; Ashton, Terence J.R.; Limpenny, Robert J.; Stevenson, Tim

    2004-03-11

    We are investigating Transition-Edge Sensors (TESs) for future X-ray Astronomy missions. In this paper, we report the first X-ray results from a one-dimensional imaging spectrometer or Distributed Read-Out Imaging Device (DROID). The DROID consists of two Iridium TESs with transitions temperatures of {approx}172 mK, at the ends of a 250 {mu}m by 4.7 mm Gold absorber. The event position can be determined from pulse height and rise/fall time information. Initial results were obtained by reading one end of the DROID only.

  12. First results from a 1-D imaging spectrometer using Ir TESs

    International Nuclear Information System (INIS)

    Smith, S.J.Stephen J.; Whitford, Chris; Fraser, George W.; Holland, Andrew D.; Goldie, David; Ashton, Terence J.R.; Limpenny, Robert J.; Stevenson, Tim

    2004-01-01

    We are investigating Transition-Edge Sensors (TESs) for future X-ray Astronomy missions. In this paper, we report the first X-ray results from a one-dimensional imaging spectrometer or Distributed Read-Out Imaging Device (DROID). The DROID consists of two Iridium TESs with transitions temperatures of ∼172 mK, at the ends of a 250 μm by 4.7 mm Gold absorber. The event position can be determined from pulse height and rise/fall time information. Initial results were obtained by reading one end of the DROID only

  13. Trajectory Design to Mitigate Risk on the Transiting Exoplanet Survey Satellite (TESS) Mission

    Science.gov (United States)

    Dichmann, Donald

    2016-01-01

    The Transiting Exoplanet Survey Satellite (TESS) will employ a highly eccentric Earth orbit, in 2:1 lunar resonance, reached with a lunar flyby preceded by 3.5 phasing loops. The TESS mission has limited propellant and several orbit constraints. Based on analysis and simulation, we have designed the phasing loops to reduce delta-V and to mitigate risk due to maneuver execution errors. We have automated the trajectory design process and use distributed processing to generate and to optimize nominal trajectories, check constraint satisfaction, and finally model the effects of maneuver errors to identify trajectories that best meet the mission requirements.

  14. Note: Establishing α-particle radiation damage experiments using the Dalton Cumbrian Facility’s 5 MV tandem pelletron

    Energy Technology Data Exchange (ETDEWEB)

    Bower, W. R. [Research Centre for Radwaste Disposal, University of Manchester, Oxford Road, Manchester M13 9PL (United Kingdom); Dalton Cumbrian Facility, Westlakes Science and Technology Park, University of Manchester, Cumbria CA24 3HA (United Kingdom); Smith, A. D.; Pimblott, S. M. [Dalton Cumbrian Facility, Westlakes Science and Technology Park, University of Manchester, Cumbria CA24 3HA (United Kingdom); Pattrick, R. A. D. [Research Centre for Radwaste Disposal, University of Manchester, Oxford Road, Manchester M13 9PL (United Kingdom)

    2015-04-15

    Evaluating the radiation stability of mineral phases is a vital research challenge when assessing the performance of the materials employed in a Geological Disposal Facility for radioactive waste. This report outlines the setup and methodology for efficiently allowing the determination of the dose dependence of damage to a mineral from a single ion irradiated sample. The technique has been deployed using the Dalton Cumbrian Facility’s 5 MV tandem pelletron to irradiate a suite of minerals with a controlled α-particle ({sup 4}He{sup 2+}) beam. Such minerals are proxies for near-field clay based buffer material surrounding radioactive canisters, as well as the sorbent components of the host rock.

  15. TESS Follow-up Observing Programs at the University of Wyoming

    Science.gov (United States)

    Jang-Condell, Hannah; Kasper, David; Kar, Aman; Sorber, Rebecca; Hancock, Daniel A.; Leuquire, Jacob D.; Suhaimi, Afiq; Kobulnicky, Henry A.; Pierce, Michael; Pilachowski, Catherine A.

    2018-06-01

    The Transiting Exoplanet Survey Satellite (TESS), launched in Spring 2018, will detect thousands of new exoplanet candidates. These candidates will need to be vetted by ground-based observatories to rule out false positives. The Observatories at the University of Wyoming are well-positioned to take active roles in TESS Follow-Up Observing Program (TFOP) Working Groups. The 0.6-m Red Buttes Observatory has already demonstrated its capability to do precision photometric monitoring of transiting exoplanet targets as a participant in the Kilodegree Extremely Little Telescope Follow-Up Network (KELT-FUN). A new echelle spectrograph, Fiber High-Resolution Echelle (FHiRE), being built for the 2.3-m Wyoming InfraRed Observatory (WIRO), will enable precision radial velocity measurements of exoplanet candidates. Over 180 nights/year at both observatories will be available to our team to undertake follow-up observations of TESS Objects of Interest (TOIs). We anticipate making significant contributions to new exoplanet discoveries in the era of TESS.

  16. Preparing for TESS: Precision Ground-based Light-curves of Newly Discovered Transiting Exoplanets

    Science.gov (United States)

    Li, Yiting; Stefansson, Gudmundur; Mahadevan, Suvrath; Monson, Andy; Hebb, Leslie; Wisniewski, John; Huehnerhoff, Joseph

    2018-01-01

    NASA’s Transiting Exoplanet Survey Satellite (TESS), to be launched in early 2018, is expected to catalog a myriad of transiting exoplanet candidates ranging from Earth-sized to gas giants, orbiting a diverse range of stellar types in the solar neighborhood. In particular, TESS will find small planets orbiting the closest and brightest stars, and will enable detailed atmospheric characterizations of planets with current and future telescopes. In the TESS era, ground-based follow-up resources will play a critical role in validating and confirming the planetary nature of the candidates TESS will discover. Along with confirming the planetary nature of exoplanet transits, high precision ground-based transit observations allow us to put further constraints on exoplanet orbital parameters and transit timing variations. In this talk, we present new observations of transiting exoplanets recently discovered by the K2 mission, using the optical diffuser on the 3.5m ARC Telescope at Apache Point Observatory. These include observations of the mini-Neptunes K2-28b and K2-104b orbiting early-to-mid M-dwarfs. In addition, other recent transit observations performed using the robotic 30cm telescope at Las Campanas Observatory in Chile will be presented.

  17. Prospects for Ground-Based Detection and Follow-up of TESS-Discovered Exoplanets

    Science.gov (United States)

    Varakian, Matthew; Deming, Drake

    2018-01-01

    The Transiting Exoplanet Survey Satellite (TESS) will monitor over 200,000 main sequence dwarf stars for exoplanetary transits, with the goal of discovering small planets orbiting stars that are bright enough for follow-up observations. We here evaluate the prospects for ground-based transit detection and follow-up of the TESS-discovered planets. We focus particularly on the TESS planets that only transit once during each 27.4 day TESS observing window per region, and we calculate to what extent ground-based recovery of additional transits will be possible. Using simulated exoplanet systems from Sullivan et al. and assuming the use of a 60-cm telescope at a high quality observing site, we project the S/N ratios for transits of such planets. We use Phoenix stellar models for stars with surface temperatures from 2500K to 12000K, and we account for limb darkening, red atmospheric noise, and missed transits due to the day-night cycle and poor weather.

  18. Galactic Archaeology with TESS: Prospects for Testing the Star Formation History in the Solar Neighbourhood

    Directory of Open Access Journals (Sweden)

    Thomas Alexandra

    2017-01-01

    proposed to explain the observed age-[α/Fe] distribution of stars in the solar neighbourhood. However, robust constraints on stellar ages are currently available for only a limited number of stars. The all-sky survey TESS (Transiting Exoplanet Survey Satellite will observe the brightest stars in the sky and thus can be used to investigate the age distributions of stars in these components of the Galaxy via asteroseismology, where previously this has been diffcult using other techniques. The aim of this preliminary study was to determine whether TESS will be able to provide evidence for quenching periods during the star formation history of the Milky Way. Using a population synthesis code, we produced populations based on various stellar formation history models and limited the analysis to red-giant-branch stars. We investigated the mass-Galactic-disk-height distributions, where stellar mass was used as an age proxy, to test for whether periods of quenching can be observed by TESS. We found that even with the addition of 15% noise to the inferred masses, it will be possible for TESS to find evidence for/against quenching periods suggested in the literature (e.g. between 7 and 9 Gyr ago, therefore providing stringent constraints on the formation and evolution of the Milky Way.

  19. Galactic Archaeology with TESS: Prospects for Testing the Star Formation History in the Solar Neighbourhood

    Science.gov (United States)

    Thomas, Alexandra; Stevenson, Emma; Gittins, Fabian W. R.; Miglio, Andrea; Davies, Guy; Girardi, Léo; Campante, Tiago L.; Schofield, Mathew

    2017-10-01

    A period of quenching between the formation of the thick and thin disks of the Milky Way has been recently proposed to explain the observed age-[α/Fe] distribution of stars in the solar neighbourhood. However, robust constraints on stellar ages are currently available for only a limited number of stars. The all-sky survey TESS (Transiting Exoplanet Survey Satellite) will observe the brightest stars in the sky and thus can be used to investigate the age distributions of stars in these components of the Galaxy via asteroseismology, where previously this has been diffcult using other techniques. The aim of this preliminary study was to determine whether TESS will be able to provide evidence for quenching periods during the star formation history of the Milky Way. Using a population synthesis code, we produced populations based on various stellar formation history models and limited the analysis to red-giant-branch stars. We investigated the mass-Galactic-disk-height distributions, where stellar mass was used as an age proxy, to test for whether periods of quenching can be observed by TESS. We found that even with the addition of 15% noise to the inferred masses, it will be possible for TESS to find evidence for/against quenching periods suggested in the literature (e.g. between 7 and 9 Gyr ago), therefore providing stringent constraints on the formation and evolution of the Milky Way.

  20. "Tess of the D'Urbervilles": What the Film Left out.

    Science.gov (United States)

    Veidemanis, Gladys V.

    1988-01-01

    Compares Roman Polanski's film adaptation of "Tess of the D'Urbervilles" with the original novel by Thomas Hardy. Suggests that a comparative analysis of the two works enhances students' awareness of Hardy's artistry and sharpens their ability to respond critically to literature. (MM)

  1. TESS Follow-up Observing Program (TFOP) Working Group:A Mission-led Effort to Coordinate Community Resources to Confirm TESS Planets

    Science.gov (United States)

    Collins, Karen; Quinn, Samuel N.; Latham, David W.; Christiansen, Jessie; Ciardi, David; Dragomir, Diana; Crossfield, Ian; Seager, Sara

    2018-01-01

    The Transiting Exoplanet Survey Satellite (TESS) will observe most of the sky over a period of two years. Observations will be conducted in 26 sectors of sky coverage and each sector will be observed for ~27 days. Data from each sector is expected to produce hundreds of transiting planet candidates (PCs) per month and thousands over the two year nominal mission. The TFOP Working Group (WG) is a mission-led effort organized to efficiently provide follow-up observations to confirm candidates as planets or reject them as false positives. The primary goal of the TFOP WG is to facilitate achievement of the Level One Science Requirement to measure masses for 50 transiting planets smaller than 4 Earth radii. Secondary goals are to serve any science coming out of TESS and to foster communication and coordination both within the TESS Science Team and with the community at large. The TFOP WG is organized as five Sub Groups (SGs). SG1 will provide seeing-limited imaging to measure blending within a candidate's aperture and time-series photometry to identify false positives and in some cases to improve ephemerides, light curves, and/or transit time variation (TTV) measurements. SG2 will provide reconnaissance spectroscopy to identify astrophysical false positives and to contribute to improved host star parameters. SG3 will provide high-resolution imaging with adaptive optics, speckle imaging, and lucky imaging to detect nearby objects. SG4 will provide precise radial velocities to derive orbits of planet(s) and measure their mass(es) relative to the host star. SG5 will provide space-based photometry to confirm and/or improve the TESS photometric ephemerides, and will also provide improved light curves for transit events or TTV measurements. We describe the TFOP WG observing and planet confirmation process, the five SGs that comprise the TFOP WG, ExoFOP-TESS and other web-based tools being developed to support TFOP WG observers, other advantages of joining the TFOP WG, the TFOP

  2. Microwave measurement test results of circular waveguide components for electron cyclotron resonant heating (ECRH) of the Tandem Mirror Experiment-Upgrade (TMX-U)

    International Nuclear Information System (INIS)

    Williams, C.W.; Rubert, R.R.; Coffield, F.E.; Felker, B.; Stallard, B.W.; Taska, J.

    1983-01-01

    Development of high-power components for electron cyclotron resonant heating (ECRH) applications requires extensive testing. In this paper we describe the high-power testing of various circular waveguide components designed for application on the Tandem Mirror Experiment-Upgrade (TMX-U). These include a 2.5-in. vacuum valve, polarizing reflectors, directional couplers, mode converters, and flexible waveguides. All of these components were tested to 200 kW power level with 40-ms pulses. Cold tests were used to determine field distribution. The techniques used in these tests are illustrated. The new high-power test facility at Lawrence Livermore National Laboratory (LLNL) is described and test procedures are discussed. We discuss the following test results: efficiency at high power of mode converters, comparison of high power vs low power for waveguide components, and full power tests of the waveguide system. We also explain the reasons behind selection of these systems for use on TMX-U

  3. Introduction to tandem mirror physics

    International Nuclear Information System (INIS)

    Kesner, J.; Gerver, M.J.; Lane, B.G.; McVey, B.D.; Catto, P.J.; D'Ippolito, D.A.; Myra, J.R.

    1983-09-01

    This monograph, prepared jointly by the MIT Plasma Fusion Center Mirror Fusion group and SAI, Boulder, Colorado, presents a review of the development of mirror fusion theory from its conception some thirty years ago to the present. Pertinent historic experiments and their contribution are discussed to set the stage for a detailed analysis of current experiments and the problems which remain to be solved in bringing tandem mirror magnetic confinement fusion to fruition. In particular, Chapter III discusses in detail the equilibrium and stability questions which must be dealt with before tandem mirror reactors become feasible, while Chapters IV and V discuss some of the current machines and those under construction which will help to resolve critical issues in both physics and engineering whose solutions are necessary to the commercialization of tandem mirror fusion

  4. Trajectory Design Enhancements to Mitigate Risk for the Transiting Exoplanet Survey Satellite (TESS)

    Science.gov (United States)

    Dichmann, Donald; Parker, Joel; Nickel, Craig; Lutz, Stephen

    2016-01-01

    The Transiting Exoplanet Survey Satellite (TESS) will employ a highly eccentric Earth orbit, in 2:1 lunar resonance, which will be reached with a lunar flyby preceded by 3.5 phasing loops. The TESS mission has limited propellant and several constraints on the science orbit and on the phasing loops. Based on analysis and simulation, we have designed the phasing loops to reduce delta-V (DV) and to mitigate risk due to maneuver execution errors. We have automated the trajectory design process and use distributed processing to generate and optimal nominal trajectories; to check constraint satisfaction; and finally to model the effects of maneuver errors to identify trajectories that best meet the mission requirements.

  5. Using TESS to predict transcription factor binding sites in DNA sequence.

    Science.gov (United States)

    Schug, Jonathan

    2008-03-01

    This unit describes how to use the Transcription Element Search System (TESS). This Web site predicts transcription factor binding sites (TFBS) in DNA sequence using two different kinds of models of sites, strings and positional weight matrices. The binding of transcription factors to DNA is a major part of the control of gene expression. Transcription factors exhibit sequence-specific binding; they form stronger bonds to some DNA sequences than to others. Identification of a good binding site in the promoter for a gene suggests the possibility that the corresponding factor may play a role in the regulation of that gene. However, the sequences transcription factors recognize are typically short and allow for some amount of mismatch. Because of this, binding sites for a factor can typically be found at random every few hundred to a thousand base pairs. TESS has features to help sort through and evaluate the significance of predicted sites.

  6. The Representation of Women in Thomas Hardy's Tess of the d'Urbervilles

    Directory of Open Access Journals (Sweden)

    Sabah Abdul Hameed Shakury

    2016-11-01

    Full Text Available This paper is an examination and exploration of Thomas Hardy’s representation of women in his novel, Tess of the d’Urbervilles. It provides a brief evaluation of the era in which Hardy was writing, placing emphasis on the psycho-sexual intricacies of the late Victorian era and their impact upon the characterization of women. The paper also shows Hardy’s attitudes toward women and how these attitudes affected his representation of women characters. The picture of vigorous womanhood and a victim of forces beyond control is clearly portrayed in Tess, the heroine. Women are presented as sensual creatures and weak. Hardy portrays women affected by the pressure exerted on them by their environment and heredity. Due to their humanity, suffering is inevitable and guilt is a common compassion.

  7. 7 Tesla quantitative hip MRI: a comparison between TESS and CPMG for T2 mapping.

    Science.gov (United States)

    Kraff, Oliver; Lazik-Palm, Andrea; Heule, Rahel; Theysohn, Jens M; Bieri, Oliver; Quick, Harald H

    2016-06-01

    We aimed to evaluate the feasibility of triple-echo steady state (TESS) T2 mapping as an alternative to conventional multi-echo-spin-echo (CPMG) T2 mapping for the quantitative assessment of hip joint cartilage at 7 T. A total of eight healthy volunteers and three patients were included. Reproducibility of both techniques was evaluated in five volunteers in five scans each. T2 relaxation times were measured by manually drawing regions of interest in multiple regions of the hip joint. Data from both methods were compared using Pearson correlation coefficient, intra-class correlation coefficient, and coefficient of repeatability. The overall image quality and presence of artifacts was assessed. Cartilage transplant and surrounding fluid were well depicted by both methods. Compared to CPMG, TESS provided systematically reduced T2 values (43.3 ± 7.3 vs. 19.2 ± 5.5 ms for acetabular cartilage, and 41.4 ± 5.6 vs. 21.7 ± 5.2 ms for femoral cartilage), in line with previously reported values. No correlation between both methods was found. TESS yielded a slightly better reproducibility than CPMG, while CPMG showed pronounced sensitivity to B1 inhomogeneities. TESS seems to be an attractive alternative to CPMG for improvements in quantitative hip joint imaging at 7 T, allowing shortening of the total acquisition time paired with insensitivity to B1, while rendering comparable image quality with good repeatability.

  8. A Big Data Analytics Pipeline for the Analysis of TESS Full Frame Images

    Science.gov (United States)

    Wampler-Doty, Matthew; Pierce Doty, John

    2015-12-01

    We present a novel method for producing a catalogue of extra-solar planets and transients using the full frame image data from TESS. Our method involves (1) creating a fast Monte Carlo simulation of the TESS science instruments, (2) using the simulation to create a labeled dataset consisting of exoplanets with various orbital durations as well as transients (such as tidal disruption events), (3) using supervised machine learning to find optimal matched filters, Support Vector Machines (SVMs) and statistical classifiers (i.e. naïve Bayes and Markov Random Fields) to detect astronomical objects of interest and (4) “Big Data” analysis to produce a catalogue based on the TESS data. We will apply the resulting methods to all stars in the full frame images. We hope that by providing libraries that conform to industry standards of Free Open Source Software we may invite researchers from the astronomical community as well as the wider data-analytics community to contribute to our effort.

  9. High-Resolution Spectroscopy at the Wyoming Infrared Observatory: Setting TESS Science on FHiRE

    Science.gov (United States)

    Jang-Condell, Hannah; Pierce, Michael J.; Pilachowski, C. A.; Kobulnicky, Henry; McLane, Jacob N.

    2018-01-01

    The Fiber High Resolution Echelle (FHiRE) spectrograph is a new instrument designed for the 2.3-m Wyoming InfraRed Observatory (WIRO). With the construction of a vacuum chamber for FHiRE to stabilize the spectrograph and a temperature-stabilized Thorium-Argon lamp for precise velocity calibration, we will be able to achieve 1 m/s RV precision, making it an ideal instrument for finding exoplanets. Details of the design of FHiRE are presented in a companion poster (Pierce et al.). The construction of this instrument is well-timed with the planned 2018 launch of NASA's Transiting Exoplanet Survey Satellite (TESS) mission. TESS will require a great deal of follow-up spectroscopy to characterize potential exoplanet host stars as well as radial velocity measurements to confirm new exoplanets. WIRO is ideally suited to acquire the long-term, high-cadence observations that will be required to make progress in this frontier area of astrophysics. We will coordinate our efforts with the TESS Follow-up Observing Program (TFOP), specifically as part of the Recon Spectroscopy and Precise Radial Velocity Work sub-groups.This work is supported by a grant from NASA EPSCOR.

  10. Maximizing the TESS Mission’s Yield of Long-Period Planets

    Science.gov (United States)

    Dragomir, Diana; Gaudi, B. Scott; Villanueva, Steven; Crossfield, Ian; Huang, Xu; Ribas, Ignasi; Quinn, Samuel

    2018-01-01

    The upcoming TESS mission will discover thousands of transiting planets around bright stars. However, during its primary mission the satellite will observe most of the sky for just 27 days (and for at most one year even in its continuous viewing zones near the ecliptic poles), thus limiting the mission’s yield of long-period planets that show three or more transits in the TESS light curves. By also pursuing single- and double-transit events, we can increase by several hundred the number of planets with periods longer than 10 days that TESS will discover. I will show how strategic planning and the judicious use of follow-up observations can confirm these planets and refine their ephemerides. Through this program, we will generate a sample of long-period planets transiting bright stars that are ripe for detailed characterization studies such as mass measurements and atmospheric observations. In turn, these studies will provide important constraints on the composition and formation of long-period planets.

  11. The influence of impurity and particle control on TMX-U [Tandem Mirror Experiment Upgrade] plasma operation

    International Nuclear Information System (INIS)

    Allen, S.L.; Yu, T.L.; Foote, J.H.; Pickles, W.L.

    1985-11-01

    A variety of techniques are used in TMX-U to control impurities and reflux: repeated plasma pulses, glow discharge cleaning (GDC), and gettering. A series of experiments under three different plasma-wall conditions was performed: no wall conditioning after a machine maintenance cycle, a glow-discharge-cleaned wall, and a gettered wall. Several plasma diagnostics to determine the effect of these procedures on TMX-U plasma parameters were used. Spectroscopic measurements indicated that GDC reduced impurities and increased the electron temperature, enabling full-duration beam-sustained plasma operation without a large number of repeated plasma pulses. Gettering further reduced the impurities and the neutral pressure, and this improved condition persisted for several shots after gettering was stopped. Measurements from residual gas analyzers and an end-loss ion spectrometer indicated that hydrogen is present in the plasma during the initial deuterium operation after pumpdown; the hydrogen level decreased after plasma operation with gettering, indicating reduced wall recycling

  12. Quality assurance (QA) for operations of fusion machines as applied to the tandem mirror experiment upgrade (TMX-U)

    International Nuclear Information System (INIS)

    Chargin, A.K.; Damm, C.C.; Turner, W.C.

    1983-01-01

    Even the best QA plan and its successful execution during construction of a typical fusion machine will produce hardware that is inoperative for some fraction of time. Operating a machine with its hardware out of tolerance, with respect to the specifications, does produce data which is the goal of the experiment. However, a majority of such data are difficult to interpret and may not contribute to understanding the behavior of the experiment. In addition, few fusion machines just operate. The majority of the machines are in the process of being rebuilt and/or added to as they operate. These modifications can keep an otherwise operational machine from running. To insure quality in operation of TMX-U, the authors employ a series of QA procedures. They start with technical milestones, schedules, and budgets that are all negotiated with DOE. Within that framework they implement a total management scheme which, in addition to normal schedule and budget controls, includes: detailed experimental run plans, definition of machine configuration required to accomplish the run plan, subsystem work-ups, instrument calibration, verification of subsystem operation, and repetition of standard physics plasma parameters. All of these activities must be completed before taking data for the experimental run plan. If a subsystem is found out of tolerance, a decision must be made either to delay operation and fix the problem or to continue on a contingency-run plan which should still produce the data relevant to the project milestones. In this presentation those QA procedures for TMX-U operations that are applied to minimize the cost and time required to achieve the technical objectives are discussed

  13. Towards a comparable carbon footprint for local initiatives: The FP7 project TESS

    Science.gov (United States)

    Reusser, Dominik E.; Kropp, Jürgen P.

    2014-05-01

    TESS (Towards European Societal Sustainability -- www.tess-transition.eu) is a three-year, European-wide research project. It aims to reach an understanding of the potential for community-led initiatives to help deliver a truly sustainable, low-carbon future. Transitions to low-carbon societies take place at multiple and complementary scales. Transition processes are highly dependent on the innovative potential of community-based initiatives and their articulation with appropriate institutional architecture. Community-based initiatives are potentially more adaptable and less constrained by current structural circumstances than top-down policies and can give impetus to large-scale and technology driven changes. TESS will provide an understanding on the upscaling possibilities of such high-potential community-based initiatives by addressing two main questions: What is the impact of community-based initiatives in terms of carbon reduction potential and economic effect? What institutional structures (values, policies and mechanisms) support these initiatives in persisting beyond the initial phase and moving into an acceleration phase, spreading desired impacts? Answers will be provided through (1) a novel measuring, reporting and verification (MRV) framework for benchmarking community-based initiatives. This will enable quantifiable, comparable and standardised evaluation, and (2) the identification of success factors for the emergence, persistence and diffusion of promising initiatives, including online initiatives. We will identify these initiatives through case studies across regions and sectors and produce a systemic understanding of their impact on societal transitions towards sustainability. Our research will be integrated and transdisciplinary, with the unique opportunity to bring together social and natural scientists to foster a transition towards European societal sustainability. Our work will feed into and extend the Climate Adapt database to facilitate

  14. Empirical Accurate Masses and Radii of Single Stars with TESS and Gaia

    Science.gov (United States)

    Stassun, Keivan G.; Corsaro, Enrico; Pepper, Joshua A.; Gaudi, B. Scott

    2018-01-01

    We present a methodology for the determination of empirical masses of single stars through the combination of three direct observables with Gaia and Transiting Exoplanet Survey Satellite (TESS): (i) the surface gravity via granulation-driven variations in the TESS light curve, (ii) the bolometric flux at Earth via the broadband spectral energy distribution, and (iii) the distance via the Gaia parallax. We demonstrate the method using 525 Kepler stars for which these measures are available in the literature, and show that the stellar masses can be measured with this method to a precision of ∼25%, limited by the surface-gravity precision of the granulation “flicker” method (∼0.1 dex) and by the parallax uncertainties (∼10% for the Kepler sample). We explore the impact of expected improvements in the surface gravity determinations—through the application of granulation background fitting and the use of recently published granulation-metallicity relations—and improvements in the parallaxes with the arrival of the Gaia second data release. We show that the application of this methodology to stars that will be observed by TESS should yield radii good to a few percent and masses good to ≈10%. Importantly, the method does not require the presence of an orbiting, eclipsing, or transiting body, nor does it require spatial resolution of the stellar surface. Thus, we can anticipate the determination of fundamental, accurate stellar radii and masses for hundreds of thousands of bright single stars—across the entire sky and spanning the Hertzsprung–Russell diagram—including those that will ultimately be found to host planets.

  15. Tandem Terminal Ion Source

    International Nuclear Information System (INIS)

    Harper, G.C.; Lindner, C.E.; Myers, A.W.; Wechel, T.D. van

    2000-01-01

    OAK-B135 Tandem Terminal Ion Source. The terminal ion source (TIS) was used in several experiments during this reporting period, all for the 7 Be(γ) 8 B experiment. Most of the runs used 1 H + at terminal voltages from 0.3 MV to 1.5 MV. One of the runs used 2 H + at terminal voltage of 1.4 MV. The other run used 4 He + at a terminal voltage of 1.37 MV. The list of experiments run with the TIS to date is given in table 1 below. The tank was opened four times for unscheduled source repairs. On one occasion the tank was opened to replace the einzel lens power supply which had failed. The 10 kV unit was replaced with a 15 kV unit. The second time the tank was opened to repair the extractor supply which was damaged by a tank spark. On the next occasion the tank was opened to replace a source canal which had sputtered away. Finally, the tank was opened to replace the discharge bottle which had been coated with aluminum sputtered from the exit canal

  16. Tandem Terminal Ion Source

    International Nuclear Information System (INIS)

    None

    2000-01-01

    OAK-B135 Tandem Terminal Ion Source. The terminal ion source (TIS) was used in several experiments during this reporting period, all for the(sup 7)Be((gamma))(sup 8)B experiment. Most of the runs used(sup 1)H(sup+) at terminal voltages from 0.3 MV to 1.5 MV. One of the runs used(sup 2)H(sup+) at terminal voltage of 1.4 MV. The other run used(sup 4)He(sup+) at a terminal voltage of 1.37 MV. The list of experiments run with the TIS to date is given in table 1 below. The tank was opened four times for unscheduled source repairs. On one occasion the tank was opened to replace the einzel lens power supply which had failed. The 10 kV unit was replaced with a 15 kV unit. The second time the tank was opened to repair the extractor supply which was damaged by a tank spark. On the next occasion the tank was opened to replace a source canal which had sputtered away. Finally, the tank was opened to replace the discharge bottle which had been coated with aluminum sputtered from the exit canal

  17. Large tandem accelerators

    International Nuclear Information System (INIS)

    Jones, C.M.

    1976-01-01

    The increasing importance of energetic heavy ion beams in the study of atomic physics, nuclear physics, and materials science has partially or wholly motivated the construction of a new generation of tandem accelerators designed to operate at maximum terminal potentials in the range 14 to 30 MV. In addition, a number of older tandem accelerators are now being significantly upgraded to improve their heavy ion performance. Both of these developments have reemphasized the importance of negative heavy ion sources. The new large tandem accelerators are described, and the requirements placed on negative heavy ion source technology by these and other tandem accelerators used for the acceleration of heavy ions are discussed. First, a brief description is given of the large tandem accelerators which have been completed recently, are under construction, or are funded for construction, second, the motivation for construction of these accelerators is discussed, and last, criteria for negative ion sources for use with these accelerators are presented

  18. Brief-stimulus presentations on multiform tandem schedules

    OpenAIRE

    Reed, Phil

    1994-01-01

    Three experiments examined the influence of a brief stimulus (a light) on the behavior of food-deprived rats whose lever pressing on tandem schedules comprising components of different schedule types resulted in food presentation. In Experiment 1, either a tandem variable-ratio variable-interval or a tandem variable-interval variable-ratio schedule was used. The variable-interval requirement in the tandem variable-ratio variable-interval schedule was yoked to the time taken to complete the va...

  19. Cross-cultural adaptation and validation of the Japanese version of the Toronto Extremity Salvage Score (TESS) for patients with malignant musculoskeletal tumors in the lower extremities.

    Science.gov (United States)

    Ogura, Koichi; Uehara, Kosuke; Akiyama, Toru; Iwata, Shintaro; Shinoda, Yusuke; Kobayashi, Eisuke; Saita, Kazuo; Yonemoto, Tsukasa; Kawano, Hirotaka; Chuman, Hirokazu; Davis, Aileen M; Kawai, Akira

    2015-11-01

    Before this work a Japanese version of the Toronto Extremity Salvage Score (TESS), a disease-specific patient-completed questionnaire widely used to assess the physical function of patients with musculoskeletal tumors, had not been developed. The purpose of this study was cross-cultural adaptation and validation of the English-language version of the TESS to facilitate international comparisons of treatment results. The TESS was translated into Japanese, back-translated into English, and reviewed by a committee to develop a consensus Japanese version of the TESS. One hundred and two patients were assessed by use of this Japanese version to examine its reliability and validity. Test-retest reliability and internal consistency determined by using the intraclass correlation coefficient (0.941) and Cronbach's alpha test (0.978), respectively, were excellent. Factor analysis showed that the structure consisted of a three-item cluster; the Akaike information criterion (AIC) network also demonstrated that the items could be divided into three domains in accordance with their content. The Japanese version of the TESS correlated with the Musculoskeletal Tumor Society rating scale (r = 0.811; P TESS is a reliable and valid instrument for measuring patient-reported functional outcome for patients with lower extremity sarcoma, and that it enables international comparisons of treatment results. The spatial association of each item demonstrated by using the AIC network also suggested that the underlying structure of the TESS reflected its coverage of a wide range of physical functions.

  20. Cross-cultural adaptation and validation of the Japanese version of the Toronto Extremity Salvage Score (TESS) for patients with malignant musculoskeletal tumors in the upper extremities.

    Science.gov (United States)

    Akiyama, Toru; Uehara, Kosuke; Ogura, Koichi; Shinoda, Yusuke; Iwata, Shintaro; Saita, Kazuo; Tanzawa, Yoshikazu; Nakatani, Fumihiko; Yonemoto, Tsukasa; Kawano, Hirotaka; Davis, Aileen M; Kawai, Akira

    2017-01-01

    The Toronto Extremity Salvage Score (TESS) is a widely used disease-specific patient-completed questionnaire for the assessment of physical function in patients with musculoskeletal tumors; however, there had not been the validated Japanese version of the TESS. The aim of this study was to validate the Japanese version of the TESS in patients with musculoskeletal tumors in the upper extremity. After developing a Japanese version of the TESS, the questionnaire was administered to 53 patients to examine its reliability and validity in comparison with the Musculoskeletal Tumor Society (MSTS) scoring system and Short Form-36 (SF-36). Test-retest reliability with intraclass correlation coefficient (0.93) and internal consistency with Cronbach's alpha (0.90) were excellent. Factor analysis showed that the construct structure consisted of 3-item clusters, and the Akaike Information Criterion network also demonstrated that the items could be divided into 3 domains according to their content. The TESS strongly correlated with the MSTS rating scale (r = 0.750; P TESS had low correlations with the SF-36 mental health and role-emotional subscales and the MSTS scoring system manual dexterity domain. Our study suggests that the TESS is a reliable and valid instrument to measure patient-reported physical functioning in patients with upper extremity sarcoma. Copyright © 2016 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.

  1. Results of the Total Evolutive Shoulder System (TESS): a single-centre study of 56 consecutive patients.

    Science.gov (United States)

    Kadum, Bakir; Mafi, Nader; Norberg, Sigge; Sayed-Noor, Arkan S

    2011-12-01

    Shoulder arthroplasty surgery has undergone remarkable progress. New concepts like reverse and stemless shoulder prostheses have been widely used. The Total Evolutive Shoulder System (TESS) is a new innovative system that provides the surgeon with different prosthetic versions. The purpose of the present study was to evaluate our short-term results and complications of the TESS. 56 consecutive patients were operated with one of the two versions of TESS (anatomical or reverse) between October 2007 and December 2009. Preoperative and postoperative evaluation of the function and life quality was achieved by the Quick Disability of the Arm, Shoulder and Hand (DASH) index and EQ-5D self-report questionnaire, respectively. Radiographic follow-up by anteroposterior, axillary and lateral views was done. The anterosuperior approach was used in all cases. We compared the outcome in fracture patients with other categories. 49 patients were available for 9-24 months (mean 14) clinical and radiographic postoperative follow-up. The mean of quick DASH improved from 56 preoperatively to 34 postoperatively (p TESS prosthesis showed promising short-term results with few complications. The reverse version could be implanted without stem if initial stability was adequate. Long-term follow-up is required to confirm the results of this innovative system in the long run.

  2. An optical test bench for the precision characterization of absolute quantum efficiency for the TESS CCD detectors

    International Nuclear Information System (INIS)

    Krishnamurthy, A.; Villasenor, J.; Kissel, S.; Ricker, G.; Vanderspek, R.

    2017-01-01

    The Transiting Exoplanet Survey Satellite (TESS) will search for planets transiting bright stars with Ic ∼< 13. TESS has been selected by NASA for launch in 2018 as an Astrophysics Explorer mission, and is expected to discover a thousand or more planets that are smaller in size than Neptune. TESS will employ four wide-field optical charge-coupled device (CCD) cameras with a band-pass of 650 nm–1050 nm to detect temporary drops in brightness of stars due to planetary transits. The 1050 nm limit is set by the quantum efficiency (QE) of the CCDs. The detector assembly consists of four back-illuminated MIT Lincoln Laboratory CCID-80 devices. Each CCID-80 device consists of 2048×2048 imaging array and 2048×2048 frame store regions. Very precise on-ground calibration and characterization of CCD detectors will significantly assist in the analysis of the science data obtained in space. The characterization of the absolute QE of the CCD detectors is a crucial part of the characterization process because QE affects the performance of the CCD significantly over the redder wavelengths at which TESS will be operating. An optical test bench with significantly high photometric stability has been developed to perform precise QE measurements. The design of the test setup along with key hardware, methodology, and results from the test campaign are presented.

  3. The Telehealth Satisfaction Scale (TeSS): Reliability, validity, and satisfaction with telehealth in a rural memory clinic population

    Science.gov (United States)

    Morgan, Debra G; Kosteniuk, Julie; Stewart, Norma; O’Connell, Megan E; Karunanyake, Chandima; Beever, Rob

    2015-01-01

    Introduction Patient satisfaction is a key aspect of quality of care and can inform continuous quality improvement. Of the few studies that have reported on patient satisfaction with telehealth in programs aimed at individuals with memory problems, none has reported on the psychometric properties of the user satisfaction scales employed. Methods We evaluated the construct validity and internal consistency reliability of the Telehealth Satisfaction Scale (TeSS), a 10-item scale adapted for use in a Rural and Remote Memory Clinic (RRMC). The RRMC is a one-stop interprofessional clinic for rural and remote seniors with suspected dementia, located in a tertiary care hospital. Telehealth videoconferencing is used for pre-clinic assessment and for follow-up. Patients and caregivers completed the TeSS after each telehealth appointment. With data from 223 patients, exploratory factor analysis was conducted using the principal components analysis extraction method. Results The eigenvalue for the first factor (5.2) was greater than 1 and much larger than the second eigenvalue (.92), supporting a one-factor solution that was confirmed by the scree plot. The total variance explained by factor 1 was 52.1%. Factor loadings (range 0.54 – 0.84) were above recommended cutoffs. The TeSS items demonstrated high internal consistency reliability (Cronbach’s alpha = 0.90). Satisfaction scores on the TeSS items ranged from 3.43 to 3.72 on a 4-point Likert scale, indicating high satisfaction with telehealth. Conclusions The study findings demonstrate high user satisfaction with telehealth in a rural memory clinic, and sound psychometric properties of the TeSS in this population. PMID:25272141

  4. Synergies Between the Kepler, K2 and TESS Missions with the PLATO Mission (Revised)

    Science.gov (United States)

    Jenkins, Jon M.

    2017-01-01

    Two transit survey missions will have been flown by NASA prior to the launch of ESA's PLATO Mission in 2026, laying the groundwork for exoplanet discovery via the transit method. The Kepler Mission, which launched in 2009, collected data on its 100+ square degree field of view for four years before failure of a reaction wheel ended its primary mission. The results from Kepler include 2300+ confirmed or validated exoplanets, 2200+ planetary candidates, 2100+ eclipsing binaries. Kepler also revolutionized the field of asteroseismology by measuring the pressure mode oscillations of over 15000 solar-like stars spanning the lifecycle of such stars from hydrogen-burning dwarfs to helium-burning red giants. The re-purposed Kepler Mission, dubbed K2, continues to observe fields of view in and near the ecliptic plane for 80 days each, significantly broadening the scope of the astrophysical investigations as well as discovering an additional 156 exoplanets to date. The TESS mission will launch in 2017 to conduct an all-sky survey for small exoplanets orbiting stars 10X closer and 100X brighter than Kepler exoplanet host stars, allowing for far greater follow-up and characterization of their masses as well as their sizes for at least 50 small planets. Future assets such as James Webb Space Telescope, and ground-based assets such as ESOs Very Large Telescope (VLT) array, the Exremely Large Telescope (ELT), and the Thirty Meter Telescope (TMT) will be able to characterize the atmospheric composition and properties of these small planets. TESS will observe each 24 X 96 field of view for 30 days and thereby cover first the southern and then the northern hemisphere over 13 pointings during each year of the primary mission. The pole-most camera will observe the James Webb continuous viewing zone for one year in each hemisphere, permitting much longer period planets to be detected in this region. The PLATO mission will seek to detect habitable Earth-like planets with an instrument

  5. An Comparative Study of Jane Eyre's Fate and Tess's Fate from Femi?nist Viewpoint

    Institute of Scientific and Technical Information of China (English)

    CHEN Jing; HE Ling-jing

    2017-01-01

    In"Jane Eyre", Charlotte Bronte's masterpiece the heroine, Jane Eyre has fully reflected her self-esteem, equality, and pure personality, which are also reflected in her concept of love vividly. However, Thomas Hardy's Tess is poor and kind, but she does not have a complete love like Jane Eyre, and she is described by his criticism of the old moral character with good vir-tues in the traditional sense. She is a new image of modern feminism who suffered from the old moral sense and gradually has re-volt consciousness. From the feminism viewpoint, this paper attempts to analysis the causes of their different fate from different points and reveal the impact of social background on their fates.

  6. Optical Design of the Camera for Transiting Exoplanet Survey Satellite (TESS)

    Science.gov (United States)

    Chrisp, Michael; Clark, Kristin; Primeau, Brian; Dalpiaz, Michael; Lennon, Joseph

    2015-01-01

    The optical design of the wide field of view refractive camera, 34 degrees diagonal field, for the TESS payload is described. This fast f/1.4 cryogenic camera, operating at -75 C, has no vignetting for maximum light gathering within the size and weight constraints. Four of these cameras capture full frames of star images for photometric searches of planet crossings. The optical design evolution, from the initial Petzval design, took advantage of Forbes aspheres to develop a hybrid design form. This maximized the correction from the two aspherics resulting in a reduction of average spot size by sixty percent in the final design. An external long wavelength pass filter was replaced by an internal filter coating on a lens to save weight, and has been fabricated to meet the specifications. The stray light requirements were met by an extended lens hood baffle design, giving the necessary off-axis attenuation.

  7. Triple focussing electron spectrum selector (TESS-II) with a pair of sector magnets

    International Nuclear Information System (INIS)

    Nagai, Y.; Ejiri, H.; Shibata, T.; Okada, K.; Nakayama, S.; Suzuki, H.; Ohsumi, H.; Adachi, Y.; Osaka Univ., Toyonaka; Sakai, H.

    1982-01-01

    An achromatic geminate nuclear electron selector (AGNES) has been constructed for in-beam electron spectroscopy. It is essentially a pair of triple-focussing electron spectrum selectors (TESS). It consists of a pair of sector magnets with a field index n = 0. Conversion electrons emitted at 90 0 and 180 0 with respect to the beam axis are transported achromatically through the pair of sector magnets to two focussing points. Electrons are triply focussed in radial, vertical and momentum axes, and their energies are analyzed by cooled Si(Li) detectors. It has a large solid angle of 50 msr x 2 and a large momentum range of 57%. It is quite useful not only for measuring conversion coefficients and electron anisotropy but also for nuclear electron pairs. (orig.)

  8. Monte Carlo Analysis as a Trajectory Design Driver for the TESS Mission

    Science.gov (United States)

    Nickel, Craig; Lebois, Ryan; Lutz, Stephen; Dichmann, Donald; Parker, Joel

    2016-01-01

    The Transiting Exoplanet Survey Satellite (TESS) will be injected into a highly eccentric Earth orbit and fly 3.5 phasing loops followed by a lunar flyby to enter a mission orbit with lunar 2:1 resonance. Through the phasing loops and mission orbit, the trajectory is significantly affected by lunar and solar gravity. We have developed a trajectory design to achieve the mission orbit and meet mission constraints, including eclipse avoidance and a 30-year geostationary orbit avoidance requirement. A parallelized Monte Carlo simulation was performed to validate the trajectory after injecting common perturbations, including launch dispersions, orbit determination errors, and maneuver execution errors. The Monte Carlo analysis helped identify mission risks and is used in the trajectory selection process.

  9. Monte Carlo Analysis as a Trajectory Design Driver for the Transiting Exoplanet Survey Satellite (TESS) Mission

    Science.gov (United States)

    Nickel, Craig; Parker, Joel; Dichmann, Don; Lebois, Ryan; Lutz, Stephen

    2016-01-01

    The Transiting Exoplanet Survey Satellite (TESS) will be injected into a highly eccentric Earth orbit and fly 3.5 phasing loops followed by a lunar flyby to enter a mission orbit with lunar 2:1 resonance. Through the phasing loops and mission orbit, the trajectory is significantly affected by lunar and solar gravity. We have developed a trajectory design to achieve the mission orbit and meet mission constraints, including eclipse avoidance and a 30-year geostationary orbit avoidance requirement. A parallelized Monte Carlo simulation was performed to validate the trajectory after injecting common perturbations, including launch dispersions, orbit determination errors, and maneuver execution errors. The Monte Carlo analysis helped identify mission risks and is used in the trajectory selection process.

  10. Students' Reading Responses to Tess of the d'Urbervilles, a Novel by Thomas Hardy

    Directory of Open Access Journals (Sweden)

    Yazid Basthomi

    2016-02-01

    Full Text Available The study explored how students responded to Tess of the d'Urbervilles, a novel by Thomas Hardy. This study was a case study of an in-tact class of Prose I at the English Department, Universitas Negeri Malang. The data were collected from 25 students, and were in the form of students' papers, written in English, which were of the students' personal responses towards the novel. The study found that the students resorted to their re-ligius knowledge (ideology when responding to the characters and subject matter of the novel. Students also developed certain kinds of feeling (emotion as their religious ideology was challenged by that offered by the novel. The study also diclosed that the students' responses fell into the categories of thematic and empathetic. It follows that teachers of Literature need to make attempts to situate the students to arrive at higher level of responses: motivational, predictive, and critical-evaluative.

  11. Restoration of the joint geometry and outcome after stemless TESS shoulder arthroplasty.

    Science.gov (United States)

    von Engelhardt, Lars V; Manzke, Michael; Breil-Wirth, Andreas; Filler, Timm J; Jerosch, Joerg

    2017-10-18

    To evaluate the joint geometry and the clinical outcome of stemless, anatomical shoulder arthroplasty with the TESS system. Twenty-one shoulders with a mean follow-up 18 of months were included. On scaled digital radiographs the premorbid center of rotation (CoR) was assessed and compared to the CoR of the prosthesis by using the MediCAD ® software. Additionally, the pre- and post-operative geometry of the CoR was assessed in relation to the glenoid, the acromion as well as to the proximal humerus. Radiological changes, such as radiolucencies, were also assessed. Clinical outcome was assessed with the Constant and DASH score. Both, the Constant and DASH scores improved significantly from 11% to 75% and from 70 to 30 points, P 0.05). The pre- and postoperative humeral offset, the lateral glenohumeral offset, the height of the CoR, the acromiohumeral distance as well as neck-shaft angle showed no significant changes ( P > 0.05). The mean deviation of the CoR of the prosthesis from the anatomic center was 1.0 ± 2.8 mm. Three cases showed a medial deviation of more than 3 mm. These deviations of 5.1, 5.7 and 7.6 mm and were caused by an inaccurate humeral neck cut. These 3 patients showed a relatively poor outcome scoring. TESS arthroplasty allows an anatomical joint reconstruction with a very good outcome. Outliers described in this study sensitize the surgeon for an accurate humeral neck cut.

  12. Tandem mirror technology demonstration facility

    Energy Technology Data Exchange (ETDEWEB)

    1983-10-01

    This report describes a facility for generating engineering data on the nuclear technologies needed to build an engineering test reactor (ETR). The facility, based on a tandem mirror operating in the Kelley mode, could be used to produce a high neutron flux (1.4 MW/M/sup 2/) on an 8-m/sup 2/ test area for testing fusion blankets. Runs of more than 100 h, with an average availability of 30%, would produce a fluence of 5 mW/yr/m/sup 2/ and give the necessary experience for successful operation of an ETR.

  13. Tandem mirror technology demonstration facility

    International Nuclear Information System (INIS)

    1983-10-01

    This report describes a facility for generating engineering data on the nuclear technologies needed to build an engineering test reactor (ETR). The facility, based on a tandem mirror operating in the Kelley mode, could be used to produce a high neutron flux (1.4 MW/M 2 ) on an 8-m 2 test area for testing fusion blankets. Runs of more than 100 h, with an average availability of 30%, would produce a fluence of 5 mW/yr/m 2 and give the necessary experience for successful operation of an ETR

  14. Tandem mass spectrometry at low kinetic energy

    International Nuclear Information System (INIS)

    Cooks, R.G.; Hand, O.W.

    1987-01-01

    Recent progress in mass spectrometry, as applied to molecular analysis, is reviewed with emphasis on tandem mass spectrometry. Tandem instruments use multiple analyzers (sector magnets, quadrupole mass filters and time-of-flight devices) to select particular molecules in ionic form, react them in the gas-phase and then record the mass, momenta or kinetic energies of their products. The capabilities of tandem mass spectrometry for identification of individual molecules or particular classes of compounds in complex mixtures are illustrated. Several different types of experiments can be run using a tandem mass spectrometer; all share the feature of sifting the molecular mixture being analyzed on the basis of chemical properties expressed in terms of ionic mass, kinetic energy or charge state. Applications of mass spectrometry to biological problems often depend upon desorption methods of ionization in which samples are bombarded with particle beams. Evaporation of preformed charged species from the condensed phase into the vacuum is a particularly effective method of ionization. It is suggested that the use of accelerator mass spectrometers be extended to include problems of molecular analysis. In such experiments, low energy tandem mass spectrometry conducted in the eV or keV range of energies, would be followed by further characterization of the production ion beam using high selective MeV collision processes

  15. Simulated JWST/NIRISS Transit Spectroscopy of Anticipated TESS Planets Compared to Select Discoveries from Space-Based and Ground-Based Surveys

    Science.gov (United States)

    Louie, Dana; Deming, Drake; Albert, Loic; Bouma, Luke; Bean, Jacob; Lopez-Morales, Mercedes

    2018-01-01

    The Transiting Exoplanet Survey Satellite (TESS) will embark in 2018 on a 2-year wide-field survey mission of most of the celestial sky, discovering over a thousand super-Earth and sub-Neptune-sized exoplanets potentially suitable for follow-up observations using the James Webb Space Telescope (JWST). Bouma et al. (2017) and Sullivan et al. (2015) used Monte Carlo simulations to predict the properties of the planetary systems that TESS is likely to detect, basing their simulations upon Kepler-derived planet occurrence rates and photometric performance models for the TESS cameras. We employed a JWST Near InfraRed Imager and Slitless Spectrograph (NIRISS) simulation tool to estimate the signal-to-noise (S/N) that JWST/NIRISS will attain in transmission spectroscopy of these anticipated TESS discoveries, and we then compared the S/N for anticipated TESS discoveries to our estimates of S/N for 18 known exoplanets. We analyzed the sensitivity of our results to planetary composition, cloud cover, and presence of an observational noise floor. We find that only a few anticipated TESS discoveries in the terrestrial planet regime will result in better JWST/NIRISS S/N than currently known exoplanets, such as the TRAPPIST-1 planets, GJ1132b, or LHS1140b. However, we emphasize that this outcome is based upon Kepler-derived occurrence rates, and that co-planar compact systems (e.g. TRAPPIST-1) were not included in predicting the anticipated TESS planet yield. Furthermore, our results show that several hundred anticipated TESS discoveries in the super-Earth and sub-Neptune regime will produce S/N higher than currently known exoplanets such as K2-3b or K2-3c. We apply our results to estimate the scope of a JWST follow-up observation program devoted to mapping the transition region between high molecular weight and primordial planetary atmospheres.

  16. Simulated JWST/NIRISS Spectroscopy of Anticipated TESS Planets and Selected Super-Earths Discovered from K2 and Ground-Based Surveys

    Science.gov (United States)

    Louie, Dana; Albert, Loic; Deming, Drake

    2017-01-01

    The 2018 launch of James Webb Space Telescope (JWST), coupled with the 2017 launch of the Transiting Exoplanet Survey Satellite (TESS), heralds a new era in Exoplanet Science, with TESS projected to detect over one thousand transiting sub-Neptune-sized planets (Ricker et al, 2014), and JWST offering unprecedented spectroscopic capabilities. Sullivan et al (2015) used Monte Carlo simulations to predict the properties of the planets that TESS is likely to detect, and published a catalog of 962 simulated TESS planets. Prior to TESS launch, the re-scoped Kepler K2 mission and ground-based surveys such as MEarth continue to seek nearby Earth-like exoplanets orbiting M-dwarf host stars. The exoplanet community will undoubtedly employ JWST for atmospheric characterization follow-up studies of promising exoplanets, but the targeted planets for these studies must be chosen wisely to maximize JWST science return. The goal of this project is to estimate the capabilities of JWST’s Near InfraRed Imager and Slitless Spectrograph (NIRISS)—operating with the GR700XD grism in Single Object Slitless Spectrography (SOSS) mode—during observations of exoplanets transiting their host stars. We compare results obtained for the simulated TESS planets, confirmed K2-discovered super-Earths, and exoplanets discovered using ground-based surveys. By determining the target planet characteristics that result in the most favorable JWST observing conditions, we can optimize the choice of target planets in future JWST follow-on atmospheric characterization studies.

  17. Cultural adaptation, translation and validation of a functional outcome questionnaire (TESS) to Portuguese with application to patients with lower extremity osteosarcoma.

    Science.gov (United States)

    Saraiva, Daniela; de Camargo, Beatriz; Davis, Aileen M

    2008-05-01

    Evaluation of physical functioning is an important tool for planning rehabilitation. Instruments need to be culturally adapted for use in non-English speaking countries. The aim of this study was to culturally adapt, including translation and preliminary validation, the Toronto extremity salvage score (TESS) for Brazil, in a sample of adolescents and young adults treated for lower extremity osteosarcoma. The process included two independent forward translations of TESS questionnaire, consensus between translators on a forward translation, back-translation by two independent translators, and a review of the back-translations. Internal consistency of the TESS and known groups validity were also evaluated. Internal consistency for the 30 item TESS was high (coefficient alpha = 0.87). TESS score ranges from 0 to 100. Forty-eight patients completed the questionnaire and scores ranged from 56 to 100 (mean score: 89.6). Patients receiving no pain medications scored higher on the TESS than those who were receiving pain medication (P = 0.014), and patients using walking aids had slightly higher but not statistically different scores. Those who were treated with amputation had higher scores than those who were treated with limb salvage procedures (P = 0.003). Preliminary evidence suggests that Brazilian-Portuguese translation is acceptable, understandable, reliable, and valid for evaluating the function in adolescents and young adults with osteosarcoma in lower extremity in Brazil. (c) 2008 Wiley-Liss, Inc.

  18. Simultaneous multislice triple-echo steady-state (SMS-TESS) T1 , T2 , PD, and off-resonance mapping in the human brain.

    Science.gov (United States)

    Heule, Rahel; Celicanin, Zarko; Kozerke, Sebastian; Bieri, Oliver

    2018-02-21

    To investigate the ability of simultaneous multislice triple-echo steady-state (SMS-TESS) imaging to provide quantitative maps of multiple tissue parameters, i.e., longitudinal and transverse relaxation times (T 1 and T 2 ), proton density (PD), and off-resonance (ΔB 0 ), in the human brain at 3T from a single scan. TESS acquisitions were performed in 2D mode to reduce motion sensitivity and accelerated by an SMS excitation scheme (CAIPIRINHA) with SENSE reconstruction. SMS-acceleration factors (R) of 2 and 4 were evaluated. The in vitro and in vivo validation process included standard reference scans to analyze the accuracy of T 1 , T 2 , and ΔB 0 estimates, as well as single-slice TESS measurements. For R = 2, the quantification of T 1 , T 2 , PD, and ΔB 0 was overall reliable with marginal noise enhancement. T 1 and T 2 values were in good agreement with the reference measurements and single-slice TESS. For R = 4, the agreement of ΔB 0 with the standard reference was excellent and the determination of T 1 , T 2 , and PD was reproducible; however, increased variations in T 1 and T 2 values with respect to single-slice TESS were observed. SMS-TESS has shown potential to offer rapid simultaneous T 1 , T 2 , PD, and ΔB 0 mapping of human brain tissues. © 2018 International Society for Magnetic Resonance in Medicine.

  19. 25 MV tandem accelerator at Oak Ridge

    International Nuclear Information System (INIS)

    Jones, C.M.

    1980-01-01

    A new heavy-ion accelerator facility is under construction at the Oak Ridge National Laboratory. A brief description of the scope and status of this project is presented with emphasis on the first operational experience with the 25 MV tandem accelerator

  20. Tandem mirror next step conceptual design

    International Nuclear Information System (INIS)

    Doggett, J.N.; Damm, C.C.; Bulmer, R.H.

    1980-01-01

    A study was made to define the features of the experimental mirror fusion device - The Tandem Mirror Next Step, or TMNS - that will bridge the gap between present mirror confinement experiments and a power-producing reactor. We outline the project goals, describe some initial device parameters, and relate the technological requirements to ongoing development programs

  1. From moon stones to simulation - More than 40 years of experiments on the 7 MV tandem accelerator at Cea/Dam Ile de France; Des pierres de lune a la simulation - Plus de 40 ans d'experiences aupres de l'accelerateur Van de Graaff tandem 7 MV CEA/DAM Ile de France

    Energy Technology Data Exchange (ETDEWEB)

    Bauge, E.; Bersillon, O.; Couillaud, Ch.; Daugas, J.M.; Flament, J.L.; Frehaut, J.; Haouat, G.; Joly, S.; Laborie, J.M.; Ledoux, X.; Marmouget, J.G.; Patin, Y.; Poncy, J.L.; Sigaud, J.; Varignon, C

    2009-07-01

    Following the decommissioning of the 7 MV tandem accelerator of CEA/DAM by the end of 2007, the present report relates the history of the accelerator from its beginning in the sixties and then the nuclear physics studies on fission, (x,xn) reactions, elastic and inelastic scattering, etc and other studies in microelectronics, biology, etc) performed with that installation. (authors)

  2. Development of a compassion-focused and contextual behavioural environment and validation of the Therapeutic Environment Scales (TESS).

    Science.gov (United States)

    Veale, David; Miles, Sarah; Naismith, Iona; Pieta, Maria; Gilbert, Paul

    2016-02-01

    Aims and method The aims of the study were to develop a scale sensitive enough to measure the interpersonal processes within a therapeutic environment, and to explore whether the new scale was sensitive enough to detect differences between settings, including a community based on compassionate mind and contextual behaviourism. The Therapeutic Environment Scales (TESS) were validated with 81 participants in three different settings: a specialist service for anxiety disorders, a specialist in-patient ward and a psychodynamic therapeutic community. Results TESS was found to be reliable and valid. Significant differences were seen between the services on the dimensions of compassion, belongingness, feeling safe, positive reinforcement of members' acts of courage, extinction and accommodation of unhelpful behaviours, inconsistency and high expressed emotion. These processes were over time associated with improved outcomes on a specialist service for anxiety disorders. Clinical implications The TESS offers a first step in exploring important interpersonal relationships in therapeutic environments and communities. An environment based on a compassionate mind and contextual behaviourism offers promise for the running of a therapeutic community.

  3. Tandem mirror reactor

    International Nuclear Information System (INIS)

    Moir, R.W.; Barr, W.L.; Carlson, G.A.

    1977-01-01

    A parametric analysis and a preliminary conceptual design for a 1000 MWe Tandem Mirror Reactor (TMR) are described. The concept is sufficiently attractive to encourage further work, both for a pure fusion TMR and a low technology TMR Fusion-Fission Hybrid

  4. Edge diagnostics for tandem mirror machines

    International Nuclear Information System (INIS)

    Allen, S.L.

    1984-01-01

    The edge plasma in a tandem mirror machine shields the plasma core from cold neutral gas and impurities. A variety of diagnostics are used to measure the fueling, shielding, and confinement of the edge plasma in both the end plug and central cell regions. Fast ion gauges and residual gas analyzers measure the gas pressure and composition outside of the plasma. An array of Langmuir probes is used to measure the electron density and temperature. Extreme ultraviolet (euv) and visible spectroscopy are used to measure both the impurity and deuterium densities and to estimate the shielding factor for the core plasma. The linear geometry of a tandem mirror also allows direct measurements of the edge plasma by sampling the ions and electrons lost but the ends of the machine. Representative data obtained by these diagnostics during operation of the Tandem Mirror Experiment (TMX) and Tandem Mirror Experiment-Upgrade (TMX-U) experiments are presented. Diagnostics that are currently being developed to diagnose the edge plasma are also discussed

  5. Assembly, alignment and test of the Transiting Exoplanet Survey Satellite (TESS) optical assemblies

    Science.gov (United States)

    Balonek, Gregory; Brown, Joshua J.; Andre, James E.; Chesbrough, Christian D.; Chrisp, Michael P.; Dalpiaz, Michael; Lennon, Joseph; Richards, B. C.; Clark, Kristin E.

    2017-08-01

    The Transiting Exoplanet Survey Satellite (TESS) will carry four visible waveband, seven-element, refractive F/1.4 lenses, each with a 34 degree diagonal field of view. This paper describes the methods used for the assembly, alignment and test of the four flight optical assemblies. Prior to commencing the build of the four flight optical assemblies, a Risk Reduction Unit (RRU) was successfully assembled and tested [1]. The lessons learned from the RRU were applied to the build of the flight assemblies. The main modifications to the flight assemblies include the inking of the third lens element stray light mitigation, tighter alignment tolerances, and diamond turning for critical mechanical surfaces. Each of the optical assemblies was tested interferometrically and measured with a low coherence distance measuring interferometer (DMI) to predict the optimal shim thickness between the lens assembly and detector before -75°C environmental testing. In addition to individual test data, environmental test results from prior assemblies allow for the exploration of marginal performance differences between each of the optical assemblies.

  6. Leveraging the Thousands of Known Planets to Inform TESS Follow-Up

    Science.gov (United States)

    Ballard, Sarah

    2017-10-01

    The Solar System furnishes our most familiar planetary architecture: many planets, orbiting nearly coplanar to one another. However, a typical system of planets in the Milky Way orbits a much smaller M dwarf star, and these stars furnish a different blueprint in key ways than the conditions that nourished evolution of life on Earth. With ensemble studies of hundreds-to-thousands of exoplanets, I will describe the emerging links between planet formation from disks, orbital dynamics of planets, and the content and observability of planetary atmospheres. These quantities can be tied to observables even in discovery light curves, to enable judicious selection of follow-up targets from the ground and from space. After TESS exoplanet discoveries start in earnest, the studies of individual planets with large, space-based platforms comprise the clear next step toward understanding the hospitability of the Milky Way to life. Our success hinges upon leveraging the many thousands of planet discoveries in hand to determine how to use these precious and limited resources.

  7. A PSF photometry tool for NASA's Kepler, K2, and TESS missions

    Science.gov (United States)

    Cardoso, Jose Vinicius De Miranda; Barentsen, Geert; Hedges, Christina L.; Gully-Santiago, Michael A.; Cody, Ann Marie; Montet, Ben

    2018-01-01

    NASA's Kepler and K2 missions have impacted all areas of astrophysics in unique and important ways by delivering high-precision time series data on asteroids, stars, and galaxies. For example, both the official Kepler pipeline and the various community-owned pipelines have been successful at discovering a myriad of transiting exoplanets around a wide range of stellar types. However, the existing pipelines tend to focus on studying isolated stars using simple aperture photometry, and often perform sub-optimally in crowded fields where objects are blended. To address this issue, we present a Point Spread Function (PSF) photometry toolkit for Kepler and K2 which is able to extract light curves from crowded regions, such as the Beehive Cluster, the Lagoon Nebula, and the M67 globular cluster, which were all recently observed by Kepler. We present a detailed discussion on the theory, the practical use, and demonstrate our tool on various levels of crowding. Finally, we discuss the future use of the tool on data from the TESS mission. The code is open source and available on GitHub as part of the PyKE toolkit for Kepler/K2 data analysis.

  8. Teleneurology to improve stroke care in rural areas: The Telemedicine in Stroke in Swabia (TESS) Project.

    Science.gov (United States)

    Wiborg, Andreas; Widder, Bernhard

    2003-12-01

    Assessing both stroke patients and their CT scans by using a conventional videoconference system offers an interesting opportunity to improve stroke care in rural areas. However, until now there have been no studies to suggest whether this method is feasible in routine stroke management. Seven rural hospitals in the southern part of Germany in Swabia were connected to the stroke unit of Günzburg with the use of a videoconference link (Telemedicine in Stroke in Swabia [TESS] Project). The local physicians are free to present every admitted stroke patient to the Günzburg stroke expert, who can assess the clinical status and CT images, thereafter giving therapeutic recommendations. All teleconsultations are rated concerning transmission quality and relevance of telemedicine for stroke management. A total of 153 stroke patients were examined by teleconsultation. Mean age was 67.5 years. Eighty-seven patients had suffered an ischemic stroke, 9 had an intracerebral hemorrhage, and 17 suffered a transient ischemic attack. Forty patients were revealed to have a diagnosis other than stroke. Duration of teleconsultation was 15 minutes on average. User satisfaction was good concerning imaging and audio quality, and patient satisfaction was very good or good in all cases. Relevant contributions could be made in >75% of the cases concerning diagnostic workup, CT assessment, and therapeutic recommendations. Teleconsultation using a videoconference system seems to be a feasible and promising method to improve stroke care in rural areas where management in a stroke unit is hindered by long transportation distances.

  9. A Numerical Simulation Of The Pulse Sequence Reconstruction in AC Biased TESs With a β Source

    International Nuclear Information System (INIS)

    Ferrari, Lorenza; Vaccarone, Renzo

    2009-01-01

    We study the response of micro-calorimeters based on Ir/Au TESs biased by an AC voltage in the MHz range to the power input generated by beta emission in a Re source thermally connected to the calorimeter itself. The micro-calorimeter is assumed to work at -80 mK, and the energy pulses corresponding to the beta emission have an energy distributed between zero and 2.58 KeV. In this numerical simulation the TES is inserted in a RLC resonating circuit, with a low quality factor. The thermal conductivities between the source and the calorimeter and that from the calorimeter to the heat sink are non-linear. The superconducting to normal transition of the TES is described by a realistic non-linear model. The AC current at the carrier frequency, modulated by the changing resistance of the TES, is demodulated and the output is filtered. The resulting signal is analyzed to deduce the attainable time resolution and the linearity of the response.

  10. The tandem betatron accelerator

    International Nuclear Information System (INIS)

    Keinigs, R.

    1991-01-01

    This paper reports that the tandem betatron is a compact, high-current induction accelerator that has the capability to accelerate electrons to an energy of order one gigavolt. Based upon the operating principle of a conventional betatron, the tandem betatron employs two synchronized induction cores operating 180 degrees out of phase. Embedded within the cores are the vacuum chambers, and these are connected by linear transport sections to allow for moving the beam back and forth between the two betatrons. The 180 degree phase shift between the core fluxes permits the circumvention of the flux swing constraint that limits the maximum energy gain of a conventional betatron. By transporting the beam between the synchronized cores, an electron can access more than one acceleration cycle, and thereby continue to gain energy. This added degree of freedom also permits a significant decrease in the size of the magnet system. Biasing coils provide independent control of the confining magnetic field. Provided that efficient beam switching can be performed, it appears feasible that a one gigavolt electron beam can be generated and confined. At this energy, a high current electron beam circulating in a one meter radius orbit could provide a very intense source of short wavelength (λ < 10 nm) synchrotron radiation. This has direct application to the emerging field of x-ray lithography. At more modest energies (10 MeV-30 MEV) a compact tandem betatron could be employed in the fields of medical radiation therapy, industrial radiography, and materials processing

  11. Tandem mirror next step: remote maintenance

    International Nuclear Information System (INIS)

    Doggett, J.N.; Damm, C.C.; Hanson, C.L.

    1980-01-01

    This study of the next proposed experiment in the Mirror Fusion Program, the Tandem Mirror Next Step (TMNS), has included serious consideration of the maintenance requirements of such a large source of high energy neutrons with its attendant throughput of tritium. Although maintenance will be costly in time and money, our conclusion is that with careful attention to a design for maintenance plan such a device can be reliably operated

  12. Status of JAERI tandem accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida, Tadashi; Kanda, Susumu; Takeuchi, Suehiro [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment] (and others)

    2001-02-01

    JAERI Tandem Accelerator had been operated approximately 230 days in fiscal year of 1999. Meanwhile, we had three times of maintenance period with vent. Total operation-times were 5273 hours. We could not carry out the experiment using rare gas, due to malfunction of the RF power supply for the ECR ion source. The type of the RF power supply is peculiar and it is impossible to get spare parts for repair. We are now investigating the backup RF power supply. The power supply for the magnet became unstable due to degradation of insulation in the shunt resistance, which is used for feedback stabilization. Stability was recovered after cleaning. The acrylic resin shaft was cracked. This cracks have a potential for severe accidents. So far bearing of the shaft has no problem. The reason of cracks may be self-destruction by charge accumulation in the shaft. JAERI Tandem Accelerator is approximately 20 years old. There appear requirements on the higher ion currents for additional ion species. Therefore, authors are investigating cost effective improvement plans of RFQ (Radio Frequency Quadra-pole) and IH type accelerator based on KEK (High Energy Accelerator Research Organization) R and D. As a whole, maintenance services for the control system are increasing due to some changes of computer programs. There are some difficulties to keep skilled personnel for facilities operation. Authors are gradually increasing hired personnel with contract from 1993. However, loads for JAERI permanent staffs are still heavy. It takes much longer time to educate skilled persons especially for safety. (Y. Tanaka)

  13. Quality evaluation of tandem mass spectral libraries.

    Science.gov (United States)

    Oberacher, Herbert; Weinmann, Wolfgang; Dresen, Sebastian

    2011-06-01

    Tandem mass spectral libraries are gaining more and more importance for the identification of unknowns in different fields of research, including metabolomics, forensics, toxicology, and environmental analysis. Particularly, the recent invention of reliable, robust, and transferable libraries has increased the general acceptance of these tools. Herein, we report on results obtained from thorough evaluation of the match reliabilities of two tandem mass spectral libraries: the MSforID library established by the Oberacher group in Innsbruck and the Weinmann library established by the Weinmann group in Freiburg. Three different experiments were performed: (1) Spectra of the libraries were searched against their corresponding library after excluding either this single compound-specific spectrum or all compound-specific spectra prior to searching; (2) the libraries were searched against each other using either library as reference set or sample set; (3) spectra acquired on different mass spectrometric instruments were matched to both libraries. Almost 13,000 tandem mass spectra were included in this study. The MSforID search algorithm was used for spectral matching. Statistical evaluation of the library search results revealed that principally both libraries enable the sensitive and specific identification of compounds. Due to higher mass accuracy of the QqTOF compared with the QTrap instrument, matches to the MSforID library were more reliable when comparing spectra with both libraries. Furthermore, only the MSforID library was shown to be efficiently transferable to different kinds of tandem mass spectrometers, including "tandem-in-time" instruments; this is due to the coverage of a large range of different collision energy settings-including the very low range-which is an outstanding characteristics of the MSforID library.

  14. The concurrence of the spatio-temporal and psychological planes in Tess of the d'urbervilles and Mrs Dalloway The concurrence of the spatio-temporal and psychological planes in Tess of the d'urbervilles and Mrs Dalloway

    Directory of Open Access Journals (Sweden)

    Brunilda Tempel Reichmann

    2008-04-01

    Full Text Available For one who has read Tess of the D'Urbervilles by Thomas ardy,1 the atmosphere created by Virginia Woolf in the opening scene of Mrs Dalloway brings back to his mind the atmosphere prevailing in the "second beginning" in the novel by Hardy. Even though the phrase "second beginning' may sound puzzling, it seems to be an appropriate expression, because we can feel that Chapter XVI was conceived by Hardy himself as another beginning in the life of his female protagonist; the previous chapters being the germ of the tragedy that, were the ideology of the author a different one, could have been avoided. For one who has read Tess of the D'Urbervilles by Thomas ardy,1 the atmosphere created by Virginia Woolf in the opening scene of Mrs Dalloway brings back to his mind the atmosphere prevailing in the "second beginning" in the novel by Hardy. Even though the phrase "second beginning' may sound puzzling, it seems to be an appropriate expression, because we can feel that Chapter XVI was conceived by Hardy himself as another beginning in the life of his female protagonist; the previous chapters being the germ of the tragedy that, were the ideology of the author a different one, could have been avoided.

  15. Tandem accelerators, 1973--1974

    International Nuclear Information System (INIS)

    Howard, F.T.

    1974-01-01

    High voltage tandem accelerators are very important instruments in the field of nuclear physics research, especially in the acceleration of heavy ions. This survey identifies 77 tandems installed in 21 countries; of these, 34 are in the United States. Most installations have supplied data sheets identifying their machines and briefly characterizing their research programs. (U.S.)

  16. Tandems as injectors for synchrotrons

    International Nuclear Information System (INIS)

    Ruggiero, A.G.

    1993-01-01

    This is a review on the use of tandem electrostatic accelerators for injection and fitting of synchrotrons to accelerate intense beams of heavy ions to relativistic energies. The paper emphasizes the need of operating the tandems in pulsed mode for this application. It has been experimentally demonstrated that at present this type of accelerator still provides the most reliable and best performance. (orig.)

  17. Ultra-Sensitive Transition-Edge Sensors (TESs) for Far-IR/Submm Space-Borne Spectroscopy

    Science.gov (United States)

    Kenyon, M.; Day, P. K.; Bradford, C. M.; Bock, J .J.; Leduc, H. G.

    2011-01-01

    We have built surface micromachined thin-film metallized Si(x)N(y) optical absorbers for transition-edge sensors (TESs) suitable for the Background - Limited far-IR/Submm Spectrograph (BLISS). BLISS is a broadband (38 micrometers - 433 micrometers), grating spectrometer consisting of five wavebands each with a modest resolution of R (is) approx. 1000. Because BLISS requires the effective noise equivalent power (NEP) of the TES to be below 10 (exp 19) W/Hz(exp 1/2), our TESs consist of four long (1000 micrometers), narrow (0.4 micrometers ), and thin (0.25 micrometers ) Si(x) N(y) support beams that reduce the thermal conductance G between the substrate and the optical absorber. To reduce the heat capacity of the absorber and make the response time tau fast enough for BLISS, our absorbers are patterned into a mesh geometry with a fill factor of less than 10%. We use a bilayer of Ti/Au to make the effective impedance of the absorber match the impedance of the incoming radiation for each band. Measurements of the response time of the metallized absorbers to heat pulses show that their heat capacity exceeds the predictions of the Debye model. Our results are suggestive that the surface of the low pressure chemical vapor deposition (LPCVD) Si(x)N(y) used in the absorbers' construction is the source of microstates that dominate the heat capacity.

  18. TESS: an R package for efficiently simulating phylogenetic trees and performing Bayesian inference of lineage diversification rates.

    Science.gov (United States)

    Höhna, Sebastian; May, Michael R; Moore, Brian R

    2016-03-01

    Many fundamental questions in evolutionary biology entail estimating rates of lineage diversification (speciation-extinction) that are modeled using birth-death branching processes. We leverage recent advances in branching-process theory to develop a flexible Bayesian framework for specifying diversification models-where rates are constant, vary continuously, or change episodically through time-and implement numerical methods to estimate parameters of these models from molecular phylogenies, even when species sampling is incomplete. We enable both statistical inference and efficient simulation under these models. We also provide robust methods for comparing the relative and absolute fit of competing branching-process models to a given tree, thereby providing rigorous tests of biological hypotheses regarding patterns and processes of lineage diversification. The source code for TESS is freely available at http://cran.r-project.org/web/packages/TESS/ CONTACT: Sebastian.Hoehna@gmail.com. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  19. JAERI tandem-accelerator and tandem-booster

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida, Tadashi [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1998-03-01

    In 1982, aiming at the new development of atomic energy research, the tandem accelerator of Japan Atomic Energy Research Institute (JAERI) was installed. In fiscal year 1993, the superconducting boosters which can increase the ion energy by up to 4 times were added, and the research in the region below 1000 MeV became possible. Those are electrostatic type accelerators which are easy to be used especially in basic research field, and are useful for future research. The tandem accelerator has been operated while maintaining the first class performance as the accelerator for various kinds of heavy ion beam. It has the special shape among electrostatic type accelerators, and is excellent in the easiness of control and stability. The main particulars of the tandem accelerator are shown. As for the ion sources of the tandem accelerator, three cesium sputter type ion sources are installed on two high voltage stands. The kinds of the ions which can be accelerated are mainly negative ions. As the improvement, electron cyclotron resonance (ECR) ion sources are expected to be adopted. As for the tandem boosters, the 1/4 wavelength type resonance hollow cylinder was adopted. The constitution of the tandem boosters is explained. The way of utilizing the tandem accelerator system and the aim for hereafter are reported. (K.I.)

  20. Design of tandem mirror reactors with thermal barriers

    International Nuclear Information System (INIS)

    Carlson, G.A.

    1980-01-01

    End-plug technologies for tandem mirror reactors include high-field superconducting magnets, neutral beam injectors, and gyrotrons for electron cyclotron resonant heating (ECRH). In addition to their normal use for sustenance of the end-plug plasmas, neutral beam injectors are used for ''pumping'' trapped ions from the thermal barrier regions by charge exchange. An extra function of the axially directed pump beams is the removal of thermalized alpha particles from the reactor. The principles of tandem mirror operation with thermal barriers will be demonstrated in the upgrade of the Tandem Mirror Experiment (TMX-U) in 1981 and the tandem configuration of the Mirror fusion Test Facility (MFTF-B) in 1984

  1. Functional outcome after endoprosthetic limb-salvage therapy of primary bone tumours—a comparative analysis using the MSTS score, the TESS and the RNL index

    Science.gov (United States)

    Pomraenke, D.; Goerling, U.; Hohenberger, P.

    2007-01-01

    Limb-saving therapy for primary bone tumours is the treatment of choice. We aimed at analysing the quality of life of this group of patients by combining three different tools. Eighty-seven patients (46 females, 41 males) with a primary bone tumour of the extremity who had undergone endoprosthetic reconstruction between 1982 and 2000 were included in this retrospective study. The median age at the time of evaluation was 30 (12–73) years. The Toronto Extremity Salvage Score (TESS) and the Reintegration to Normal Living index (RNL) were recorded an average of 5.8 years after reconstruction and the Musculoskeletal Tumour Society Score (MSTS) after an average of 6.5 years. The mean MSTS score was 77% (13–93%). The mean TESS was 82% (22–99%), and the mean RNL index was 87% (32–98%). The subjective satisfaction and acceptance of physical impairment were significantly higher than the objective score (p TESS was 88% in patients aged 12–25 years, 81% in those aged 26–40 years and 57% in those aged 41–73 years. Parallel recording of the MSTS score, TESS and RNL index provides a better measure reflecting the complex situation of the patients by combining objective and subjective parameters. PMID:17701173

  2. Functional outcome after endoprosthetic limb-salvage therapy of primary bone tumours--a comparative analysis using the MSTS score, the TESS and the RNL index.

    Science.gov (United States)

    Tunn, P U; Pomraenke, D; Goerling, U; Hohenberger, P

    2008-10-01

    Limb-saving therapy for primary bone tumours is the treatment of choice. We aimed at analysing the quality of life of this group of patients by combining three different tools. Eighty-seven patients (46 females, 41 males) with a primary bone tumour of the extremity who had undergone endoprosthetic reconstruction between 1982 and 2000 were included in this retrospective study. The median age at the time of evaluation was 30 (12-73) years. The Toronto Extremity Salvage Score (TESS) and the Reintegration to Normal Living index (RNL) were recorded an average of 5.8 years after reconstruction and the Musculoskeletal Tumour Society Score (MSTS) after an average of 6.5 years. The mean MSTS score was 77% (13-93%). The mean TESS was 82% (22-99%), and the mean RNL index was 87% (32-98%). The subjective satisfaction and acceptance of physical impairment were significantly higher than the objective score (p TESS was 88% in patients aged 12-25 years, 81% in those aged 26-40 years and 57% in those aged 41-73 years. Parallel recording of the MSTS score, TESS and RNL index provides a better measure reflecting the complex situation of the patients by combining objective and subjective parameters.

  3. The Classroom Trial of "Tess of the D'Urbervilles": A Way to See, Speak, Hear, and Live a Persuasive Essay.

    Science.gov (United States)

    Young, Michael W.

    Courtroom scenes in literature seem to have a special magic with students (probably because of all the trials seen on television, fiction or non-fiction). Students in a composition and literature course at the University of Nebraska, after reading Thomas Hardy's "Tess of the D'Urbervilles," wrote "closing arguments" for either…

  4. Simulated JWST/NIRISS Transit Spectroscopy of Anticipated Tess Planets Compared to Select Discoveries from Space-based and Ground-based Surveys

    Science.gov (United States)

    Louie, Dana R.; Deming, Drake; Albert, Loic; Bouma, L. G.; Bean, Jacob; Lopez-Morales, Mercedes

    2018-04-01

    The Transiting Exoplanet Survey Satellite (TESS) will embark in 2018 on a 2 year wide-field survey mission, discovering over a thousand terrestrial, super-Earth and sub-Neptune-sized exoplanets ({R}pl}≤slant 4 {R}\\oplus ) potentially suitable for follow-up observations using the James Webb Space Telescope (JWST). This work aims to understand the suitability of anticipated TESS planet discoveries for atmospheric characterization by JWST’s Near InfraRed Imager and Slitless Spectrograph (NIRISS) by employing a simulation tool to estimate the signal-to-noise (S/N) achievable in transmission spectroscopy. We applied this tool to Monte Carlo predictions of the TESS expected planet yield and then compared the S/N for anticipated TESS discoveries to our estimates of S/N for 18 known exoplanets. We analyzed the sensitivity of our results to planetary composition, cloud cover, and presence of an observational noise floor. We find that several hundred anticipated TESS discoveries with radii 1.5 {R}\\oplus R}pl}≤slant 2.5 {R}\\oplus will produce S/N higher than currently known exoplanets in this radius regime, such as K2-3b or K2-3c. In the terrestrial planet regime, we find that only a few anticipated TESS discoveries will result in higher S/N than currently known exoplanets, such as the TRAPPIST-1 planets, GJ1132b, and LHS1140b. However, we emphasize that this outcome is based upon Kepler-derived occurrence rates, and that co-planar compact multi-planet systems (e.g., TRAPPIST-1) may be under-represented in the predicted TESS planet yield. Finally, we apply our calculations to estimate the required magnitude of a JWST follow-up program devoted to mapping the transition region between hydrogen-dominated and high molecular weight atmospheres. We find that a modest observing program of between 60 and 100 hr of charged JWST time can define the nature of that transition (e.g., step function versus a power law).

  5. Tandem mirror reactor studies at Lawrence Livermore National Laboratory, FY 1980

    Energy Technology Data Exchange (ETDEWEB)

    Carlson, G.A.; Neef, W.S. Jr.

    1981-03-20

    The principles of tandem mirror operation with thermal barriers will be demonstrated in the upgrade of the Tandem Mirror Experiment (TMX-U) in 1981 and the tandem configuration of the Mirror Fusion Test Facility (MFTF-B) in 1984. Continued analysis and conceptual design over this period will evolve the optimal configuration and parameters for a power-producing reactor. In this article we describe the progress we have made in this reactor design study effort during 1980.

  6. Tandem mirror reactor studies at Lawrence Livermore National Laboratory, FY 1980

    International Nuclear Information System (INIS)

    Carlson, G.A.; Neef, W.S. Jr.

    1981-01-01

    The principles of tandem mirror operation with thermal barriers will be demonstrated in the upgrade of the Tandem Mirror Experiment (TMX-U) in 1981 and the tandem configuration of the Mirror Fusion Test Facility (MFTF-B) in 1984. Continued analysis and conceptual design over this period will evolve the optimal configuration and parameters for a power-producing reactor. In this article we describe the progress we have made in this reactor design study effort during 1980

  7. Function Preservation After Conservative Resection and Radiotherapy for Soft-tissue Sarcoma of the Distal Extremity: Utility and Application of the Toronto Extremity Salvage Score (TESS).

    Science.gov (United States)

    Cassidy, Richard J; Indelicato, Daniel J; Gibbs, Charles P; Scarborough, Mark T; Morris, Christopher G; Zlotecki, Robert A

    2016-12-01

    To evaluate outcomes after conservative resection and radiotherapy (RT) for soft-tissue sarcoma (STS) of the distal extremity, with assessment of functional quality of life using the validated Toronto Extremity Salvage Score (TESS) questionnaire and Common Terminology Criteria for Adverse Events (CTCAE), v4.0. Thirty-three patients with STS involving the hand/wrist (N=18) or foot/ankle (N=15) complex received adjuvant RT with conservative resection and were evaluated for local tumor control, survival, toxicities, and preservation of objective functional ability. Eight patients were treated with preoperative RT (median dose, 50.4 Gy) and 25 with postoperative RT (median dose, 61.8 Gy). Median follow-up was 11.5 years. Functional outcomes were measured using TESS; patients with amputations were excluded from the TESS analysis. Adverse events related to gait, limb edema, skin infection, wound complication, and wound dehiscence were assessed using the CTCAE. The 5- and 10-year local control rates were both 90%. The 10-year cause-specific, absolute, and distant metastasis-free survival rates were 97%, 87%, and 84%, respectively. Three patients had an amputation for reasons other than local recurrence or treatment complications and underwent amputation for patient preference. One third of the subjects (11/33 patients) were able to complete the TESS questionnaire; scores ranged from 88 to 100 (mean, 98.2). CTCAEv4 acute adverse events occurred in 2 cases: 1 patient had a grade 3 skin infection and 1 had a grade 2 wound complication of dehiscence. For management of distal extremity STS, the combination of adjuvant RT and conservative surgery achieves excellent local control and overall survival with few adverse events. In addition, through application of the TESS survey instrument, we have demonstrated that this treatment plan achieves robust functional preservation objectively and quantifiably.

  8. Use of the Trauma Embolic Scoring System (TESS) to predict symptomatic deep vein thrombosis and fatal and non-fatal pulmonary embolism in severely injured patients.

    Science.gov (United States)

    Ho, K M; Rao, S; Rittenhouse, K J; Rogers, F B

    2014-11-01

    Fatal pulmonary embolism is the third most common cause of death after major trauma. We hypothesised that the Trauma Embolic Scoring System (TESS) would have adequate calibration and discrimination in a group of severely injured trauma patients in predicting venous thromboembolism (VTE), and could be used to predict fatal and non-fatal symptomatic pulmonary embolism. Calibration and discrimination of the TESS were assessed by the slope and intercept of the calibration curve and the area under the receiver operating characteristic curve, respectively. Of the 357 patients included in the study, 74 patients (21%) developed symptomatic VTE after a median period of 14 days following injury. The TESS predicted risks of VTE were higher among patients who developed VTE than those who did not (14 versus 9%, P=0.001) and had a moderate ability to discriminate between patients who developed VTE and those who did not (area under the receiver operating characteristic curve 0.71, 95% confidence interval 0.65 to 0.77). The slope and intercept of the calibration curve were 2.76 and 0.34, respectively, suggesting that the predicted risks of VTE were not sufficiently extreme and overall, underestimated the observed risks of VTE. Using 5% predicted risk of VTE as an arbitrary cut-point, TESS had a high sensitivity and negative predictive value (both ≥0.97) in excluding fatal and non-fatal pulmonary embolism. The TESS had a reasonable ability to discriminate between patients who developed VTE and those who did not and may be useful to select different strategies to prevent VTE in severely injured patients.

  9. Feedback stabilized tandem Fabry-Perot interferometer

    International Nuclear Information System (INIS)

    Fukushima, Hiroyuki; Ito, Mikio; Shirasu, Hiroshi.

    1986-01-01

    A new system for measuring the isotopic ratio of uranium, in which two plane-type Fabry-Perot interferometers (tandem FP) are connected in series. The parallelism between the two FPs is achieved automatically by a feedback control mechanism based on laser interference fringe monitoring. The structure of the tandem FP, feedback control system, automatic parallelism adjustment mechanism and wavelength synchronization mechanism are described in detail. For experiments, a hollow cathode discharge tube of a pulse discharge type is employed. Measurements are made to determine the effects of pulse width on the 238 U peak height of 502.7 nm line, recorder traces of 235 U and 238 U lines, half width for 238 U component of the 502.7 nm line, SN ratio, reproducibility of the 235 U/ 238 U peak height ratio and 235 U/ 238 U intensity ratio. Considerations are made on the spectral line width, contrast, transmission factor, and stability of automatic parallelism control and wavelength synchronization. Results obtained indicates that a single-type interferometer would serve adequately for measuring the 235 U/ 238 U ratio if the automatic parallelism control developed here is used. The ultimate object of the tandem system is to make measurement of 236 U. Satisfactory results have not obtained as yet, but most likely the present system would make it possible if a light source of a higher intensity and advanced photometric techniques are developed. (Nogami, K.)

  10. Tandem Van de Graaff facility

    Data.gov (United States)

    Federal Laboratory Consortium — Completed in 1970, the Tandem Van de Graaff facility was for many years the world's largest electrostatic accelerator facility. It can provide researchers with beams...

  11. Superconducting linacs used with tandems

    International Nuclear Information System (INIS)

    Ben-Zvi, I.

    1984-01-01

    The main features of superconducting linacs used as post-accelerators of tandems are reviewed. Various aspects of resonators, cryogenics and electronics are discussed, and recent advances in the field are presented. (orig.)

  12. An Comparative Study of Jane Eyre's Fate and Tess's Fate from Femi-nist Viewpoint%An Comparative Study of Jane Eyre's Fate and Tess's Fate from Femi?nist Viewpoint

    Institute of Scientific and Technical Information of China (English)

    陈静; 何泠静

    2017-01-01

    In"Jane Eyre", Charlotte Bronte's masterpiece the heroine, Jane Eyre has fully reflected her self-esteem, equality, and pure personality, which are also reflected in her concept of love vividly. However, Thomas Hardy's Tess is poor and kind, but she does not have a complete love like Jane Eyre, and she is described by his criticism of the old moral character with good vir-tues in the traditional sense. She is a new image of modern feminism who suffered from the old moral sense and gradually has re-volt consciousness. From the feminism viewpoint, this paper attempts to analysis the causes of their different fate from different points and reveal the impact of social background on their fates.

  13. Fusion oriented plasma research in Bangladesh: theoretical study on low-frequency dust modes and edge plasma control experiment in tandem mirror

    International Nuclear Information System (INIS)

    Khairul Islam, Md.; Salimullah, Mohammed; Yatsu, Kiyoshi; Nakashima, Yousuke; Ishimoto, Yuki

    2003-01-01

    A collaboration with a Japanese institute in the field of plasma-wall interaction and dusty plasma has been formed in order to understand the physical properties of edge plasma. Results of the theoretical study on dusty plasma and the experimental study on GAMMA10 plasma are presented in this paper. Part A deals with the results obtained from the theoretical investigation of the properties and excitation of low-frequency electrostatic dust modes, e.g. the dust-acoustic (DA) and dust-lower-hybrid (DLH) waves, using the fluid models. In this study, dust grain charge is considered as a dynamic variable in streaming magnetized dusty plasmas with a background of neutral atoms. Dust charge fluctuation, collisional and streaming effects on DA and DLH modes are discussed. Part B deals with the results of the plasma control experiment in a non-axisymmetric magnetic field region of the anchor cell of GAMMA10. The observations, which indicate the comparatively low-temperature plasma formation in the anchor cell, are explained from the viewpoint of enhanced outgassing from the wall due to the interaction of the drifted-out ions. The drifting of ions is thought to be due to the effect of a local non-axisymmetric magnetic field. Experimental results on the control of the wall-plasma interaction by covering the flux tube of a non-axisymmetric magnetic field region by conducting plates are given. Possible influences of the asymmetric magnetic field and conducting plates on the GAMMA10 plasma parameters are discussed. (author)

  14. Variability Properties of Four Million Sources in the TESS Input Catalog Observed with the Kilodegree Extremely Little Telescope Survey

    Science.gov (United States)

    Oelkers, Ryan J.; Rodriguez, Joseph E.; Stassun, Keivan G.; Pepper, Joshua; Somers, Garrett; Kafka, Stella; Stevens, Daniel J.; Beatty, Thomas G.; Siverd, Robert J.; Lund, Michael B.; Kuhn, Rudolf B.; James, David; Gaudi, B. Scott

    2018-01-01

    The Kilodegree Extremely Little Telescope (KELT) has been surveying more than 70% of the celestial sphere for nearly a decade. While the primary science goal of the survey is the discovery of transiting, large-radii planets around bright host stars, the survey has collected more than 106 images, with a typical cadence between 10–30 minutes, for more than four million sources with apparent visual magnitudes in the approximate range 7TESS Input catalog and the AAVSO Variable Star Index to precipitate the follow-up and classification of each source. The catalog is maintained as a living database on the Filtergraph visualization portal at the URL https://filtergraph.com/kelt_vars.

  15. Short-term results of the reverse Total Evolutive Shoulder System (TESS) in cuff tear arthropathy and revision arthroplasty cases.

    Science.gov (United States)

    von Engelhardt, Lars Victor; Manzke, Michael; Filler, Timm J; Jerosch, Joerg

    2015-07-01

    The aim of this study was to evaluate the clinical and radiological outcome of the Total Evolutive Shoulder System (TESS) in patients with cuff tear arthropathy and patients in need of a revision arthroplasty. In this sequential study, 67 patients (56 non-stemmed, 11 stemmed) were evaluated after a mean follow-up of 17.5 months. The relative Constant and DASH scores, radiological joint geometry changes, complications and postoperative problems, which are not likely to affect the outcome, were evaluated. A significant increase was noticed for the relative Constant (11.3 vs. 78.8 %) and DASH scores (73.7 vs. 31.8) without significant differences between both etiology groups. Complication rates were similar to previous studies. An aseptic loosening of the non-stemmed humeral component was not noticed in the cuff tear arthropathy group, whereas one case with a loosening was noticed in the revision arthroplasty group. With nine cases (13.4 %), scapular notching rates were very low. On average, the acromiohumeral distance increased by 17 mm and the humeral offset by 13.9 mm; the height of the center of rotation decreased by 4.6 mm and the lateral glenohumeral offset by 6.1 mm, p TESS system provided adequate distalization and medialization of the humerus and the center of rotation. This corresponds to a good clinical outcome. The use of the surgical opportunity to implant the prosthesis with a relatively low neck-shaft angle might explain the low rates of scapular notching in our series. Regarding the case with a loosening of the humeral component, the surgeon should carefully indicate a stemless version for metaphyseal press-fit fixation in patients with revision arthroplasty.

  16. Plasma confinement in the TMX tandem mirror

    International Nuclear Information System (INIS)

    Hooper, E.B. Jr.; Allen, S.L.; Casper, T.A.

    1981-01-01

    Plasma confinement in the Tandem Mirror Experiment (TMX) is described. Axially confining potentials are shown to exist throughout the central 20-cm core of TMX. Axial electron-confinement time is up to 100 times that of single-cell mirror machines. Radial transport of ions is smaller than axial transport near the axis. It has two parts at large radii: nonambipolar, in rough agreement with predictions from resonant-neoclassical transport theory, and ambipolar, observed near the plasma edge under certain conditions, accompanied by a low-frequency, m = 1 instability or strong turbulence

  17. JAERI 20 MV tandem accelerator

    International Nuclear Information System (INIS)

    Tsukada, Kineo; Harada, Kichinosuke

    1977-01-01

    Accelerators have been developed as the experimental apparatuses for the studies on nuclei and elementary particles. One direction of the development is the acceleration of protons and electrons to more and more high energy, and another direction is the acceleration of heavy ions up to uranium to several MeV up to several hundreds MeV. However recently, accelerators are used as the useful tools for the studies in wider fields. There are electrostatic acceleration and high frequency acceleration in ion acceleration, and at present, super-large accelerators are high frequency acceleration type. In Japan Atomic Energy Research Institute, it was decided in 1975 to construct an electrostatic accelerator of tandem type in order to accelerate heavy ions. In case of the electrostatic acceleration, the construction is relatively simple, the acceleration of heavy ions is easy, the property of the ion beam is very good, and the energy is stable. Especially, the tandem type is convenient for obtaining high energy. The tandem accelerator of 20 MV terminal voltage was ordered from the National Electrostatics Corp., USA, and is expected to be completed in 1978. The significance of heavy ion acceleration in the development and research of atomic energy, tandem van de Graaff accelerators, the JAERI 20MV tandem accelerator, and the research project with this accelerator are described. (Kako, I.)

  18. The "Bologna-München" Tandem--Experiencing Interculturality

    Science.gov (United States)

    De Martino, Sandro

    2016-01-01

    This case study describes the "Bologna-München" Tandem, a cross-border collaboration which began in 2011. The aim of the collaboration is to give students studying Italian at the Ludwig- Maximilians-University in Munich and students studying German at the University of Bologna the opportunity to experience interculturality through…

  19. Toxic Exposure Surveillance System (TESS)-based characterization of U.S. non-native venomous snake exposures, 1995-2004.

    Science.gov (United States)

    Seifert, Steven A; Oakes, Jennifer A; Boyer, Leslie V

    2007-01-01

    Non-native (exotic) snake exposures in the United States have not been systematically characterized. The Toxic Exposure Surveillance System (TESS) database of the American Association of Poison Control Centers was analyzed to quantify the number and types, demographic associations, clinical presentations, managements and outcomes, and the health resource utilization of non-native snake exposures. From 1995 through 2004, there were 399 non-native exposures in the TESS database. Of these, 350 snakes (87%) were identified by genus and species, comprising at least 77 different varieties. Roughly equal percentages of snakes originated in Asia, Africa and Latin America, with a smaller number from the Middle-East, Australia, and Europe. Nearly half were viperids and a little more than a third were elapids. The vast majority of exposed individuals were adults. However, almost 15% were aged 17 years or less, and almost 7% were children aged 5 years or younger. Eighty-four percent were males. The vast majority of exposures occurred at the victim's own residence. Over 50% were evaluated at a healthcare facility, with 28.7% admitted to an ICU. Overall, 26% of patients were coded as receiving antivenom treatment. Coded outcomes were similar between viperid and elapid envenomations. There were three deaths, two involving viperid snakes and one elapid. Enhancements to the TESS database are required for better precision in and more complete characterization of non-native snake envenomations.

  20. The TESS reverse shoulder arthroplasty without a stem in the treatment of cuff-deficient shoulder conditions: clinical and radiographic results.

    Science.gov (United States)

    Teissier, Philippe; Teissier, Jacques; Kouyoumdjian, Pascal; Asencio, Gérard

    2015-01-01

    Reverse total shoulder arthroplasty (RSA) is a recent concept that enables good functional outcomes in cases of massive rotator cuff tear and cuff tear arthropathy. Design parameters influence the functional results and complications. The purpose of this study is to present the results of a novel RSA, the Total Evolutive Shoulder System (TESS; Biomet, Warsaw, IN, USA), based on a reverse corolla without a stem. We enrolled 101 patients with 105 RSAs in a prospective study, with a minimum follow-up period of 24 months. The analysis concerned 91 RSAs in 87 patients (61 men and 26 women), with a mean age of 73 years, at a mean follow-up of 41 months (range, 24-69 months). Ninety-six percent of patients rated their satisfaction as good or excellent. Mean flexion was 143° (range, 90°-170°), and mean external rotation was 39° (range, 20°-70°). The Constant score improved from 40 points preoperatively to 68 points at last follow-up (P TESS RSA provided encouraging midterm results with favorable outcomes and a low rate of complications. The stemless TESS with a reverse corolla is a reliable, less invasive system. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  1. JAERI tandem annual report, 1982

    International Nuclear Information System (INIS)

    Harada, Kichinosuke; Maruyama, Michio; Ozawa, Kunio; Shikazono, Naomoto; Tamura, Tsutomu; Tanaka, Shigeya

    1983-06-01

    This annual report describes research activities which have been performed with JAERI tandem accelerator from September 1, 1981 to March 31, 1983. Summary reports of 38 papers, publications, personnel and a list of co-operative researches with universities are contained. (author)

  2. JAERI Tandem annual report 1983

    International Nuclear Information System (INIS)

    Harada, Kichinosuke; Maruyama, Michio; Okashita, Hiroshi; Ozawa, Kunio; Shikazono, Naomoto; Tanaka, Shigeya

    1984-07-01

    This annual report describes research activities which have been performed with JAERI tandem accelerator from April 1, 1983 to March 31, 1984. Summary reports of 32 papers, publications, personnel and a list of co-operative reserches with universities are contained. (author)

  3. Status of tandem mirror theory

    International Nuclear Information System (INIS)

    Baldwin, D.E.

    1979-01-01

    This report contains the text and slides used for the review talk on tandem mirror theory presented at the meeting of the Division of Plasma Physics, A.P.S., Boston, MA, November 12-16, 1979. Topics covered include classical confinement, equilibria, MHD- and micro-stability, radial transport, and thermal barriers

  4. Status of tandem-mirror confinement

    International Nuclear Information System (INIS)

    Baldwin, D.E.

    1983-01-01

    Recent end-stopping experiments in TMX-Upgrade show strong plugging of the central cell by lower-density plugs, requiring both electron-cyclotron heating (ECRH) and 47 0 neutral-beam injection, consistent with the thermal-barrier concept. These experiments have low density (n 12 cm -3 ) due to inefficient ECRH power coupling. Hot-ion and hot-electron buildup are consistent with Fokker-Planck calculations. No ion-cyclotron activity is observed in the plugs; occasional electron-cyclotron activity is observed. With plugging, axial lifetimes (tau/sub parallel/ > 40 ms) are larger than radial (tau/sub perpendicular/ = 5 to 10 ms) due to observed non-ambipolar ion transport. Recent tandem-mirror theoretical activities are also surveyed

  5. Progress in the tandem mirror program

    International Nuclear Information System (INIS)

    Fowler, T.K.; Borchers, R.R.

    1981-01-01

    Experimental results in TMX have confirmed the basic principles of the tandem-mirror concept. A center-cell particle confinement parameter eta tau approx. 10 11 cm -3 s has been obtained at ion temperatures around 100 eV, which is a hundred-fold improvement over single mirrors at the same temperatures. For TMX these results have been obtained at peak beta values in the center cell in the range 10 to 40%, not yet limited by MHD activity; and ion-cyclotron resonant heating (ICRH) in the Phaedrus tandem-mirror experiment has produced beta values approx. 25%, which is several times the ideal MHD limit for that device. In addition, it has been demonstrated that the end fan chambers of TMX simultaneously isolate the hot electrons from the end walls, provide adequate pumping and conveniently dispose of the exhaust plasma energy either by thermal deposition on the end wall or by direct conversion to electricity (at 48% efficiency in agreement with calculations). Also, evidence was obtained for inherent divertor action in TMX, presumably in part responsible for the observed low impurity level

  6. A study of reflex tandem accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Nakajima, Takao; Morinobu, Shunpei; Gono, Yasuyuki; Sagara, Kenji; Sugimitsu, Tsuyoshi; Mitarai, Shiro; Nakamura, Hiroyuki; Ikeda, Nobuo; Morikawa, Tsuneyasu [Kyushu Univ., Fukuoka (Japan). Faculty of Science

    1996-12-01

    An investigation on `developing research theme and its realizing experimental apparatus` based on the tandem accelerator facility is executed. At a standpoint of recognition on essentiality of preparation, improvement or novel technical development capable of extreme increase in capacity of the tandem accelerator facility to form COE with high uniqueness, proposal of numerous ideas and their investigations and searches were conducted. In this paper, consideration results of `beam reacceleration using tandem accelerator` were shown as follows: (1) Short life unstable nuclei formed by nuclear reaction using tandem acceleration primary beam is ionized to negative and to reaccelerate by using the same tandem accelerator. And (2) by combination of plural electrons with the tandem primary accelerated beam, numbers of charge is reduced to reaccelerate by the tandem. (G.K.)

  7. II-IV-V Based Thin Film Tandem Photovoltaic Cell

    Energy Technology Data Exchange (ETDEWEB)

    Newman, Nathan [Arizona State Univ., Mesa, AZ (United States); van Schilfgaarde, Mark [Arizona State Univ., Mesa, AZ (United States)

    2012-10-04

    [Through a combination of theory and experiment that, absent unknown mitigating factors, a tandem cell whose (wide-gap. 1.8 eV) top layer is made of ZnSnP2 and whose (narrow gap, 1.1 eV) bottom layer consisting of ZnGeAs2 are near-ideal materials for a tandem cell. Not only are there gaps optimally adjusted to the solar spectrum, but the two compounds are lattice-matched, and their energy band structure and optical absorption are also near-ideal (they closely resemble that of GaAs). Our first major challenge is to establish that high-quality II-IV-V thin films can be synthesized. We have begun growing and characterizing films of ZnGeAs2 and ZnSnP2, initially grown on Ge substrates (the lattice constant of Ge matches these compounds) by pulsed laser ablation and sputtering. In tandem are theoretical calculations to guide the experiments. The goal is to develop methods that can be used to produce a pair of lattice-matched thin films that will be useful in tandem cells.

  8. Tandem electrostatic accelerators for BNCT

    International Nuclear Information System (INIS)

    Ma, J.C.

    1994-01-01

    The development of boron neutron capture therapy (BNCT) into a viable therapeutic modality will depend, in part, on the availability of suitable neutron sources compatible with installation in a hospital environment. Low-energy accelerator-based intense neutron sources, using electrostatic or radio frequency quadrupole proton accelerators have been suggested for this purpose and are underdevelopment at several laboratories. New advances in tandem electrostatic accelerator technology now allow acceleration of the multi-milliampere proton beams required to produce therapeutic neutron fluxes for BNCT. The relatively compact size, low weight and high power efficiency of these machines make them particularly attractive for installation in a clinical or research facility. The authors will describe the limitations on ion beam current and available neutron flux from tandem accelerators relative to the requirements for BNCT research and therapy. Preliminary designs and shielding requirements for a tandern accelerator-based BNCT research facility will also be presented

  9. MINIMARS tandem mirror reactor study

    International Nuclear Information System (INIS)

    Perkins, L.J.; Logan, B.G.; Doggett, J.N.

    1986-01-01

    During 1985-1986, Lawrence Livermore National Lab., in partnership with the Fusion Engineering Design Center of Oak Ridge National Lab., the Univ. of Wisconsin, TRW, Grumman Aerospace Corporation, General Dynamics/Convair, Argonne National Lab., and the Canadian Fusion Fuels Technology Project, has conducted the conceptual design of MINIMARS, a small commercial tandem mirror reactor with novel octopole end plugs. With a net electric output of 600 MW(e), MINIMARS is expressly designed for short (∼4- to 5-yr) construction time, factory-built modules, and a passively safe blanket and thermal cycle. In this way, we intend to achieve a small reactor based on the tandem mirror principle that will minimize utility financial risk, thereby providing an attractive alternative to the more conventional large fusion plant designs encountered to date

  10. "Nanocrystal bilayer for tandem catalysis"

    Energy Technology Data Exchange (ETDEWEB)

    Yamada, Yusuke; Tsung, Chia Kuang; Huang, Wenyu; Huo, Ziyang; E.Habas, Susan E; Soejima, Tetsuro; Aliaga, Cesar E; Samorjai, Gabor A; Yang, Peidong

    2011-01-24

    Supported catalysts are widely used in industry and can be optimized by tuning the composition and interface of the metal nanoparticles and oxide supports. Rational design of metal-metal oxide interfaces in nanostructured catalysts is critical to achieve better reaction activities and selectivities. We introduce here a new class of nanocrystal tandem catalysts that have multiple metal-metal oxide interfaces for the catalysis of sequential reactions. We utilized a nanocrystal bilayer structure formed by assembling platinum and cerium oxide nanocube monolayers of less than 10 nm on a silica substrate. The two distinct metal-metal oxide interfaces, CeO2-Pt and Pt-SiO2, can be used to catalyse two distinct sequential reactions. The CeO2-Pt interface catalysed methanol decomposition to produce CO and H2, which were subsequently used for ethylene hydroformylation catalysed by the nearby Pt-SiO2 interface. Consequently, propanal was produced selectively from methanol and ethylene on the nanocrystal bilayer tandem catalyst. This new concept of nanocrystal tandem catalysis represents a powerful approach towards designing high-performance, multifunctional nanostructured catalysts

  11. Folded tandem ion accelerator facility at BARC

    International Nuclear Information System (INIS)

    Agarwal, Arun; Padmakumar, Sapna; Subrahmanyam, N.B.V.; Singh, V.P.; Bhatt, J.P.; Ware, Shailaja V.; Pol, S.S; Basu, A.; Singh, S.K.; Krishnagopal, S.; Bhagwat, P.V.

    2017-01-01

    The 5.5 MV single stage Van de Graaff (VDG) accelerator was in continuous operation at Nuclear Physics Division (NPD), Bhabha Atomic Research Centre (BARC) since its inception in 1962. During 1993-96, VDG accelerator was converted to a Folded Tandem Ion Accelerator (FOTIA). The scientists and engineers of NPD, IADD (then a part of NPD) along with several other divisions of BARC joined hands together in designing, fabrication, installation and commissioning of the FOTIA for the maximum terminal voltage of 6 MV. After experiencing the first accelerated ion beam on the target from FOTIA during April 2000, different ion species were accelerated and tested. Now this accelerator FOTIA is in continuous use for different kind of experiments

  12. Educational activities with a tandem accelerator

    Science.gov (United States)

    Casolaro, P.; Campajola, L.; Balzano, E.; D'Ambrosio, E.; Figari, R.; Vardaci, E.; La Rana, G.

    2018-05-01

    Selected experiments in fundamental physics have been proposed for many years at the Tandem Accelerator of the University of Napoli ‘Federico II’s Department of Physics as a part of a one-semester laboratory course for graduate students. The aim of this paper is to highlight the educational value of the experimental realization of the nuclear reaction 19F(p,α)16O. With the purpose of verifying the mass-energy equivalence principle, different aspects of both classical and modern physics can be investigated, e.g. conservation laws, atomic models, nuclear physics applications to compositional analysis, nuclear cross-section, Q-value and nuclear spectroscopic analysis.

  13. Lessons Learned from Developing and Operating the Kepler Science Pipeline and Building the TESS Science Pipeline

    Science.gov (United States)

    Jenkins, Jon M.

    2017-01-01

    The experience acquired through development, implementation and operation of the KeplerK2 science pipelines can provide lessons learned for the development of science pipelines for other missions such as NASA's Transiting Exoplanet Survey Satellite, and ESA's PLATO mission.

  14. A Collision of Vice and Virtue in Thomas Hardy’s Tess of the D’Urbervilles: “A Pure Woman Faithfully Presented” or a Fallen Angel

    Directory of Open Access Journals (Sweden)

    Nafiseh Salman Saleh

    2014-06-01

    Full Text Available Heralded as a sympathizer with the oppressed nineteenth century femininity, Thomas Hardy adopted an aggressive stance towards the institutionized codes of the time particularly the ideal of femininity which results in presenting him as one of the promethean forerunners of “New Woman” fiction. His outspoken attitudes are tangible in his fictional prose where he valiantly tries to challenge the Victorian ideals of femininity. By creating non-conformist heroines, Hardy took the first step to move away from the constitutionalized codes of the time particularly on behalf of femininity. In effect, Hardy valiantly tries to challenge the Victorian ideological discourse of femininity through spotlighting on his fictional women’s flaws which comes into conflict with the time’s conception of a pure woman. Tess of the D’Urbervilles (1891, as a typical example of his fiction, is representative of Hardy’s vision towards the Victorian ideal of femininity through the “Fallen” Tess. This paper is an attempt to re-read Hardy’s Tess of the D’Urbervilles to explore the Victorian ideal conception of femininity first and, then, an attempt has been made to delineate the discrepancy between Hardy’s perceptions of a “Fallen Woman” in contrast with the Victorian’s. This paper, finally, concludes that although Hardy’s genuine commiseration towards the “Fallen Woman” shows close affinity with the radical feminist notions of the day, Tess’s sheer misery and her final tragic death in Stonehenge attest to Hardy’s substantial contribution as a Victorian male novelist to the ideologies circulating at the time.

  15. Refractory Abundances of Terrestrial Planets and Their Stars: Testing [Si/Fe] Correlations with TESS and PLATO

    Science.gov (United States)

    Wolfgang, Angie; Fortney, Jonathan

    2018-01-01

    In standard models for planet formation, solid material in protoplanetary disks coagulate and collide to form rocky bodies. It therefore seems reasonable to assume that their chemical composition will follow the abundances of refractory elements, such as Si and Fe, in the host star, which has also accreted material from the disk. Backed by planet formation simulations which validate this assumption, planetary internal structure models have begun to use stellar abundances to break degeneracies in low-mass planet compositions inferred only from mass and radius. Inconveniently, our own Solar System contradicts this approach, as its terrestrial bodies exhibit a range of rock/iron ratios and the Sun's [Si/Fe] ratio is offset from the mean planetary [Si/Fe]. In this work, we explore what number and quality of observations we need to empirically measure the exoplanet-star [Si/Fe] correlation, given future transit missions, RV follow-up, and stellar characterization. Specifically, we generate synthetic datasets of terrestrial planet masses and radii and host star abundances assuming that the planets’ bulk [Si/Fe] ratio exactly tracks that of their host stars. We assign measurement uncertainties corresponding to expected precisions for TESS, PLATO, Gaia, and future RV instrumentation, and then invert the problem to infer the planet-star [Si/Fe] correlation given these observational constraints. Comparing the result to the generated truth, we find that 1% precision on the planet radii is needed to test whether [Si/Fe] ratios are correlated between exoplanet and host star. On the other hand, lower precisions can test for systematic offsets between planet and star [Si/Fe], which can constrain the importance of giant impacts for extrasolar terrestrial planet formation.

  16. Molecular ion acceleration using tandem accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Saito, Yuichi; Mizuhashi, Kiyoshi; Tajima, Satoshi [Japan Atomic Energy Research Inst., Takasaki, Gunma (Japan). Takasaki Radiation Chemistry Research Establishment

    1996-12-01

    In TIARA compound beam radiation system, cluster beams have been produced using 3 MV tandem accelerator (9SDH-2) to supply them to various radiation on injection experiments. Till now, productions of C{sub 2-8}, Si{sub 2-4} and O{sub 2} and their accelerations up to 6 MeV have been succeeded. This study aimed at production and acceleration of B{sub 2-4} and LiF. Anion clusters were produced using the conventional ion source of cesium sputter type. The proportions of atoms, molecules and clusters elicited from the ion source were varied depending on the material`s properties and the operating conditions of ion source such as sample temperature, sputter voltage and the shape of sample. The anion clusters were accelerated toward the high voltage terminal in the center of tandem accelerator, leading to cations through losing their electrons by the collision to N{sub 2} gas in a charge conversion cell at the terminal. Positively charged cluster ions could be obtained by modulating the pressure of N{sub 2} gas. Thus, B{sub 2} (64 nA), B{sub 3} (4.4 nA) and B{sub 4} (2.7 nA) have been produced and their maximum survival probabilities were higher than those of carbon or silicon clusters. In addition, the relationship between beam current and gas pressure was investigated for Bn (n = 2-4) and LiF. (M.N.)

  17. Injector of the Utrecht EN tandem

    Energy Technology Data Exchange (ETDEWEB)

    Borg, K. van der; Haas, A.P. de; Hoogenboom, A.M.; Strasters, B.A.; Vermeer, A.; Zwol, N.A. van (Rijksuniversiteit Utrecht (Netherlands). Fysisch Lab.)

    1984-02-15

    An injector has been built to obtain improved beam transmission through the EN tandem. The injector has been provided with a 90/sup 0/ analysing magnet, m/..delta..m=300, and 130 kV preacceleration. Beam optics calculations have been made for the injector and tandem. The injector has been equipped with a fiber optics control and data acquisition system.

  18. The injector of the Utrecht EN tandem

    International Nuclear Information System (INIS)

    Borg, K. van der; Haas, A.P. de; Hoogenboom, A.M.; Strasters, B.A.; Vermeer, A.; Zwol, N.A. van

    1984-01-01

    An injector has been built to obtain improved beam transmission through the EN tandem. The injector has been provided with a 90 0 analysing magnet, m/Δm=300, and 130 kV preacceleration. Beam optics calculations have been made for the injector and tandem. The injector has been equipped with a fiber optics control and data acquisition system. (orig.)

  19. The Kyoto University tandem upgrading project

    International Nuclear Information System (INIS)

    Nakamura, Masanobu; Shimoura, Susumu; Takimoto, Kiyohiko; Sakaguchi, Harutaka; Kobayashi, Shinsaku

    1988-01-01

    A brief description on the Kyoto University tandem upgrading project. The project consists of replacing the old 5 MV tandem Van de Graaff by an 8UDH pelletron. The old pressure vessel and beam lines are used again without significant modification. The project is planned to be completed at the end of 1989. (orig.)

  20. Parametric studies of tandem mirror reactors

    International Nuclear Information System (INIS)

    Carlson, G.A.; Boghosian, B.M.; Fink, J.H.; Myall, J.O.; Neef, W.S. Jr.

    1979-01-01

    This report, along with its companion, An Improved Tandem Mirror Reactor, discusses the recent progress and present status of our tandem mirror reactor studies. This report presents the detailed results of parametric studies up to, but not including, the very new ideas involving thermal barriers

  1. Packet models revisited: tandem and priority systems

    NARCIS (Netherlands)

    M.R.H. Mandjes (Michel)

    2004-01-01

    textabstractWe examine two extensions of traditional single-node packet-scale queueing models: tandem networks and (strict) priority systems. Two generic input processes are considered: periodic and Poisson arrivals. For the two-node tandem, an exact expression is derived for the joint distribution

  2. Tandem Translation Classroom: A Case Study

    Science.gov (United States)

    Kim, Dohun; Koh, Taejin

    2018-01-01

    The transition to student-centred learning, advances in teleconferencing tools, and active international student exchange programmes have stimulated tandem learning in many parts of the world. This pedagogical model is based on a mutual language exchange between tandem partners, where each student is a native speaker in the language the…

  3. Device operation of organic tandem solar cells

    NARCIS (Netherlands)

    Hadipour, A.; de Boer, B.; Blom, P. W. M.

    2008-01-01

    A generalized methodology is developed to obtain the current-voltage characteristic of polymer tandem solar cells by knowing the electrical performance of both sub cells. We demonstrate that the electrical characteristics of polymer tandem solar cells are correctly predicted for both the series and

  4. The Therapeutic Environment Screening Survey for Nursing Homes (TESS-NH): an observational instrument for assessing the physical environment of institutional settings for persons with dementia.

    Science.gov (United States)

    Sloane, Philip D; Mitchell, C Madeline; Weisman, Gerald; Zimmerman, Sheryl; Foley, Kristie M Long; Lynn, Mary; Calkins, Margaret; Lawton, M Powell; Teresi, Jeanne; Grant, Leslie; Lindeman, David; Montgomery, Rhonda

    2002-03-01

    To develop an observational instrument that describes the ability of physical environments of institutional settings to address therapeutic goals for persons with dementia. A National Institute on Aging workgroup identified and subsequently revised items that evaluated exit control, maintenance, cleanliness, safety, orientation/cueing, privacy, unit autonomy, outdoor access, lighting, noise, visual/tactile stimulation, space/seating, and familiarity/homelikeness. The final instrument contains 84 discrete items and one global rating. A summary scale, the Special Care Unit Environmental Quality Scale (SCUEQS), consists of 18 items. Lighting items were validated using portable light meters. Concurrent criterion validation compared SCUEQS scores with the Professional Environmental Assessment Protocol (PEAP). Interrater kappa statistics for 74% of items were above.60. For another 10% of items, kappas could not be calculated due to empty cells, but interrater agreement was above 80%. The SCUEQS demonstrated an interrater reliability of.93, a test--retest reliability of.88, and an internal consistency of.81--.83. Light meter ratings correlated significantly with the Therapeutic Environment Screening Survey for Nursing Homes (TESS-NH) lighting items (r =.29--.38, p =.01--.04), and the SCUEQS correlated significantly with global PEAP ratings (r =.52, p TESS-NH efficiently assesses discrete elements of the physical environment and has strong reliability and validity. The SCUEQS provides a quantitative measure of environmental quality in institutional settings.

  5. Tandem catalysis: a new approach to polymers.

    Science.gov (United States)

    Robert, Carine; Thomas, Christophe M

    2013-12-21

    The creation of polymers by tandem catalysis represents an exciting frontier in materials science. Tandem catalysis is one of the strategies used by Nature for building macromolecules. Living organisms generally synthesize macromolecules by in vivo enzyme-catalyzed chain growth polymerization reactions using activated monomers that have been formed within cells during complex metabolic processes. However, these biological processes rely on highly complex biocatalysts, thus limiting their industrial applications. In order to obtain polymers by tandem catalysis, homogeneous and enzyme catalysts have played a leading role in the last two decades. In the following feature article, we will describe selected published efforts to achieve these research goals.

  6. Tandem Mirror Reactor Systems Code (Version I)

    International Nuclear Information System (INIS)

    Reid, R.L.; Finn, P.A.; Gohar, M.Y.

    1985-09-01

    A computer code was developed to model a Tandem Mirror Reactor. Ths is the first Tandem Mirror Reactor model to couple, in detail, the highly linked physics, magnetics, and neutronic analysis into a single code. This report describes the code architecture, provides a summary description of the modules comprising the code, and includes an example execution of the Tandem Mirror Reactor Systems Code. Results from this code for two sensitivity studies are also included. These studies are: (1) to determine the impact of center cell plasma radius, length, and ion temperature on reactor cost and performance at constant fusion power; and (2) to determine the impact of reactor power level on cost

  7. Preliminary design of a tandem mirror reactor

    International Nuclear Information System (INIS)

    Strohmayer, J.N.

    1984-04-01

    The purpose of this thesis is to examine the TARA mirror experiment as a possible tandem mirror reactor configuration. This is a preliminary study to size the coil structure based on using the smallest end cell axial length that physics and engineering allow, zeroing the central cell parallel currents and having interchange stability. The input powers are estimated for the final reactor design so a Q value may be estimated. The Q value is defined as the fusion power divided by the total injected power absorbed by the plasma. A computer study was performed on the effect of the transition size, the transition vertical spacing and transition current. These parameters affect the central cell parallel currents, the recircularization of the flux tube and the ratio of central cell beta to anchor beta needed for marginal stability. Two designs were identified. The first uses 100 keV and 13 keV neutral beams to pump the ions that trap in the thermal barrier. The Q value of this reactor is 11.3. The second reactor uses a pump beam at 40 keV. This energy is chosen because there is a resonance for the charge exchange cross section between D 0 and He 2+ at this energy, thus the alpha ash will be pumped along with the deuterium and tritium. The Q value of this reactor is 11.6

  8. IMPACT OF SOME GEOMETRICAL ASPECTS ON THE TANDEM CO-ROTATING PROPELLER HYDRODYNAMIC CHARACTERISTICS

    Directory of Open Access Journals (Sweden)

    Boucetta Djahida

    2017-01-01

    Full Text Available In the present paper, a numerical simulation based on Kω-SST turbulence model has been carried out to determine the tandem propeller hydrodynamic characteristics in non-cavitating viscous flow by using the commercial code Fluent. As the first step, the numerical approach has been applied to the case of single propeller and the comparison with experiment results was in a good agreement. Next, the effects of axial and angular displacement as well as the diameter ratio between the tandem propellers have been investigated. This part of the study reveals that the tandem with idem propeller diameters is strongly recommended to assure more advantages. Furthermore, the tandem geometry corresponding to the axial displacement equal to 0.6D seems to be the best configuration and the open water performances remain almost unchanged with the variation of angular displacement. On the other hand, details of the mutual interaction between tandem propellers were also given by showing pressure contours, streamlines and thrust coefficient. Globally, this study illustrates the advantages of replacing single propellers by tandem solution.

  9. TASKA - Tandem Spiegelmaschine Karlsruhe. Vol. 1

    International Nuclear Information System (INIS)

    1982-06-01

    TASKA (Tandem Spiegelmaschine Karlsruhe) is a near term engineering test facility based on a tandem mirror concept with thermal barriers. The main objectives of this study were to develop a preconceptual design of a facility that could provide engineering design information for a Demonstration Fusion Power Reactor. Thus TASKA has to serve as testbed for technologies of plasma engineering, superconducting magnets, materials, plasma heating, breeding and test blankets, tritium technology, and remote handling. (orig.) [de

  10. Feasibility study on tandem fuel cycle

    International Nuclear Information System (INIS)

    Han, P.S.; Suh, I.S.; Rim, C.S.; Kim, B.K.; Suh, K.S.; Ro, S.K.; Juhn, P.I.; Kim, S.Y.

    1983-01-01

    The objective of this feasibility study is to review and assess the current state of technology concerning the tandem fuel cycle. Based on the results from this study, a long-term development plan suitable for Korea has been proposed for this cycle, i.e., the PWR → CANDU tandem fuel cycle which used plutonium and uranium, recovered from spent PWR fuel by co-processing, as fuel material for CANDU reactors. (Author)

  11. TASKA - Tandem Spiegelmaschine Karlsruhe. Vol. 2

    International Nuclear Information System (INIS)

    1982-06-01

    TASKA (Tandem Spiegelmaschine Karlsruhe) is a near term engineering test facility based on a tandem mirror concept with thermal barriers. The main objectives of this study were to develop a preconceptual design of a facility that could provide engineering design information for a Demonstration Fusion Power Reactor. Thus TASKA has to serve as testbed for technologies of plasma engineering, superconducting magnets, materials, plasma heating, breeding and test blankets, tritium technology, and remote handling. (orig.) [de

  12. North-American MP Tandem accelerators

    International Nuclear Information System (INIS)

    Wegner, H.E.; Thieberger, P.

    1977-01-01

    There are six North-American MP Tandem accelerators: Yale; Minnesota; Chalk River; Rochester; and two at Brookhaven. The current status and operating characteristics of these six tandem accelerators are discussed. Upgrade and special improvements of the different machines is reviewed and new developments since the last Electrostatic Conference are discussed in detail. The overall operating characteristics of the different machines during the last year of operation are compared

  13. Vortex shedding from tandem cylinders

    Science.gov (United States)

    Alam, Md. Mahbub; Elhimer, Mehdi; Wang, Longjun; Jacono, David Lo; Wong, C. W.

    2018-03-01

    An experimental investigation is conducted on the flow around tandem cylinders for ranges of diameter ratio d/ D = 0.25-1.0, spacing ratio L/ d = 5.5-20, and Reynolds number Re = 0.8 × 104-2.42 × 104, where d and D are the diameters of the upstream and downstream cylinders, respectively, L is the distance from the upstream cylinder center to the forward stagnation point of the downstream one. The focus is given on examining the effects of d/ D, L/ d and Re on Strouhal number St, flow structures and fluid forces measured using hotwire, particle image velocimetry (PIV) and load cell measurement techniques, respectively. Changes in d/ D and L/ d in the ranges examined lead to five flow regimes, namely lock-in, intermittent lock-in, no lock-in, subharmonic lock-in and shear-layer reattachment regimes. Time-mean drag coefficient ( C D) and fluctuating drag and lift coefficients ({C^'D} and {C^'L}) are more sensitive to L/ d than d/ D. The scenario is opposite for St where d/ D is more prominent than L/ d to change the St. The detailed facet of the dependence on d/ D and L/ d of C D, {C^'D}, {C^'L} and St is discussed based on shear-layer velocity, approaching velocity, vortex formation length, and wake width.

  14. Deep learning classification in asteroseismology using an improved neural network: results on 15 000 Kepler red giants and applications to K2 and TESS data

    Science.gov (United States)

    Hon, Marc; Stello, Dennis; Yu, Jie

    2018-05-01

    Deep learning in the form of 1D convolutional neural networks have previously been shown to be capable of efficiently classifying the evolutionary state of oscillating red giants into red giant branch stars and helium-core burning stars by recognizing visual features in their asteroseismic frequency spectra. We elaborate further on the deep learning method by developing an improved convolutional neural network classifier. To make our method useful for current and future space missions such as K2, TESS, and PLATO, we train classifiers that are able to classify the evolutionary states of lower frequency resolution spectra expected from these missions. Additionally, we provide new classifications for 8633 Kepler red giants, out of which 426 have previously not been classified using asteroseismology. This brings the total to 14983 Kepler red giants classified with our new neural network. We also verify that our classifiers are remarkably robust to suboptimal data, including low signal-to-noise and incorrect training truth labels.

  15. NeuroTessMesh: A Tool for the Generation and Visualization of Neuron Meshes and Adaptive On-the-Fly Refinement

    Directory of Open Access Journals (Sweden)

    Juan J. Garcia-Cantero

    2017-06-01

    Full Text Available Gaining a better understanding of the human brain continues to be one of the greatest challenges for science, largely because of the overwhelming complexity of the brain and the difficulty of analyzing the features and behavior of dense neural networks. Regarding analysis, 3D visualization has proven to be a useful tool for the evaluation of complex systems. However, the large number of neurons in non-trivial circuits, together with their intricate geometry, makes the visualization of a neuronal scenario an extremely challenging computational problem. Previous work in this area dealt with the generation of 3D polygonal meshes that approximated the cells’ overall anatomy but did not attempt to deal with the extremely high storage and computational cost required to manage a complex scene. This paper presents NeuroTessMesh, a tool specifically designed to cope with many of the problems associated with the visualization of neural circuits that are comprised of large numbers of cells. In addition, this method facilitates the recovery and visualization of the 3D geometry of cells included in databases, such as NeuroMorpho, and provides the tools needed to approximate missing information such as the soma’s morphology. This method takes as its only input the available compact, yet incomplete, morphological tracings of the cells as acquired by neuroscientists. It uses a multiresolution approach that combines an initial, coarse mesh generation with subsequent on-the-fly adaptive mesh refinement stages using tessellation shaders. For the coarse mesh generation, a novel approach, based on the Finite Element Method, allows approximation of the 3D shape of the soma from its incomplete description. Subsequently, the adaptive refinement process performed in the graphic card generates meshes that provide good visual quality geometries at a reasonable computational cost, both in terms of memory and rendering time. All the described techniques have been

  16. Workshop of the JAEA-Tokai Tandem Accelerator. Memorial of 100,000-hour operation

    International Nuclear Information System (INIS)

    Ishii, Tetsuro; Osa, Akihiko

    2009-04-01

    Workshop of the JAEA-Tokai tandem accelerator has been held every two years. As a memorial of 100,000-hour operation of the tandem accelerator, we have organized the workshop focusing on the activity at this facility. This workshop covers developments and experiments carried out so far, together with experiments in progress and proposals in future. As previous series of workshops, we offered an opportunity to have active discussion among scientists in different fields including accelerator, nuclear physics, nuclear chemistry, radiation effects, atomic physics and so on, aiming at extending facility and research interactively. As a memorial lecture, we invited Dr. Akira Tonomura of fellow of Hitachi, Ltd, a distinctive scientist for development of electron holography. He delivered a lecture titled 'Structure of magnetic flux observed by electron beam'. He once used the tandem accelerator to induce columnar defects in high-temperature superconductor and studied vortices trapped along the defects. Prof. Shigeru Kubono of University of Tokyo, a chairman of program advisory committee of the tandem accelerator, encouraged us through a talk of 'Expectations for the JAEA-Tokai tandem accelerator'. This workshop was held at Advanced Science Research Center Building in Nuclear Science Research Institute on January 6th and 7th in 2009, having 24 oral presentations and 48 posters, and successfully carried out with as many as 120 participants and a lot of science discussions. This review is the collection of slides of oral presentations. The colored slides can be also found in the home page of the tandem accelerator facility (http://rrsys.tokai-sc.jaea.go.jp/rrsys/html/tandem/index.html). (author)

  17. Tandemly Arrayed Genes in Vertebrate Genomes

    Directory of Open Access Journals (Sweden)

    Deng Pan

    2008-01-01

    Full Text Available Tandemly arrayed genes (TAGs are duplicated genes that are linked as neighbors on a chromosome, many of which have important physiological and biochemical functions. Here we performed a survey of these genes in 11 available vertebrate genomes. TAGs account for an average of about 14% of all genes in these vertebrate genomes, and about 25% of all duplications. The majority of TAGs (72–94% have parallel transcription orientation (i.e., they are encoded on the same strand in contrast to the genome, which has about 50% of its genes in parallel transcription orientation. The majority of tandem arrays have only two members. In all species, the proportion of genes that belong to TAGs tends to be higher in large gene families than in small ones; together with our recent finding that tandem duplication played a more important role than retroposition in large families, this fact suggests that among all types of duplication mechanisms, tandem duplication is the predominant mechanism of duplication, especially in large families. Finally, several species have a higher proportion of large tandem arrays that are species-specific than random expectation.

  18. Mass spectrometry by means of tandem accelerators

    International Nuclear Information System (INIS)

    Tuniz, C.

    1985-01-01

    Mass spectrometry based on an accelerator allows to measure rare cosmogenic isotopes found in natural samples with isotopic abundances up to 10E-15. The XTU Tandem of Legnaro National Laboratories can measure mean heavy isotopes (36Cl, 41Ca, 129I) in applications interesting cosmochronology and Medicine. The TTT-3 Tandem of the Naples University has been modified in view of precision studies of C14 in Archeology, Paleantology and Geology. In this paper a review is made of principles and methodologies and of some applicationy in the framework of the National Program for mass spectrametry research with the aid of accelerators

  19. Electron and ion cyclotron heating calculations in the tandem-mirror modeling code MERTH

    International Nuclear Information System (INIS)

    Smith, G.R.

    1985-01-01

    To better understand and predict tandem-mirror experiments, we are building a comprehensive Mirror Equilibrium Radial Transport and Heating (MERTH) code. In this paper we first describe our method for developing the code. Then we report our plans for the installation of physics packages for electron- and ion-cyclotron heating of the plasma

  20. A proposal for study of ion-beam induced chemical reactions using JAERI tandem accelerator

    International Nuclear Information System (INIS)

    1985-11-01

    Problems in ion-beam induced chemical reactions using JAERI Tandem Accelerator were discussed. Research philosophy, some proposed experiments which are based on measurements during ion-beam bombardment, and main features of the experimental apparatus are briefly described in this report. (author)

  1. Octopole and hexapole end cells for tandem mirrors

    International Nuclear Information System (INIS)

    Devoto, R.S.

    1985-01-01

    To date, nearly all operating or planned tandem mirror experiments use quadrupole magnetic fields in the end cells for stabilization of magnetohydrodynamic (MHD) instabilities. A disadvantage with quadrupole fields is the considerable aximuthal asymmetry in the magnetic field. As a result, those center-cell ions which pass into the end cell can suffer a radial deflection and be lost by radial diffusion. The diffusion can be minimized by adding C-coils to the end cell to symmetrize the geodesic curvature in the end cell. Very small radial deflection can be obtained on each field line. Such a method is used in the design of the MFTF-B experiment and the MARS reactor. A disadvantage of this approach is the large number of coils required. In addition, since ions drift azimuthally as they reflect in the end cell, even perfect cancellation on individual field lines will, in general, not lead to zero radial diffusion. One way to form a more symmetric field in the end cells is to use multipoles higher than quadrupole. The use of an octopole end cell for a small tandem-mirror reactor was recently proposed/sup L/ and has been adopted for the miniMARS reactor study. In this paper the author discusses some feature of octopole, and to a lesser extent, hexapole end cells in both reactor and experimental (MFTF-B) applications

  2. Plasma confinement in the GAMMA 10 tandem mirror

    International Nuclear Information System (INIS)

    Yatsu, K.; Bruskin, L.G.; Cho, T.

    1999-01-01

    The central-cell density and the diamagnetic signal were doubled due to plug potential formation by ECRH in the hot ion mode experiments on the GAMMA 10 tandem mirror. In order to obtain these remarkable results, the axisymmetrized heating patterns of ECRH and ICRF were optimized. Furthermore, conducting plates were installed adjacent to the surface of the plasma along the flat shaped magnetic flux tube located at the anchor transition regions; the plates may contribute to reduce some irregular electric fields produced possibly with ECRH in these thin flux tube regions. The conducting plates contributed to the reduction of the radial loss rate to be less than 3% of the total particle losses along with the improvements in the reproducibility of the experiments and the controllability of the potential confinement. The increases in the central-cell density and the diamagnetism in association with the increase in the plug potentials scaled well with increasing the ECRH powers. A plug potential of 0.6 kV and a density increase of 100% were achieved using an ECRH power of 140 kW injected into both plug regions. The plasma confinement was improved by an order of magnitude over a simple mirror confinement due to the tandem mirror potential formation. (author)

  3. Thirty years of physics at the Bucharest tandem accelerator

    International Nuclear Information System (INIS)

    Dobrescu, S.; Marinescu, L.; Dumitru, G.; Cata-Danil, Gh.

    2003-01-01

    The main parameters of the Bucharest tandem accelerator, as well as the main milestones of its history since March 1973 when it was commissioned are shortly presented. A general presentation of the main basic and applied physics research so far undertaken at the tandem is given, ending with some ideas related with the future perspectives of the tandem. (authors)

  4. STATIONARY DISTRIBUTION OF A TANDEM QUEUE WITH ADDITIONAL FLOWS ON THE STATIONS OF THE TANDEM

    Directory of Open Access Journals (Sweden)

    V. I. Klimenok

    2017-01-01

    Full Text Available A tandem queueing system consisting of a finite number of multi-server stations without buffers is analized. The input flow at the first station is a ???????????? (Markovian arrival process. The customers from this flow aim to be served at all stations of the tandem. For any station, besides transit customers proceeding from the previous station, an additional ???????????? flow of new customers arrives at this station directly. Customers from this flow aim to be served at this station and all subsequent stations of the tandem. The service times of customer at the stations are exponentially distributed with the service rate depending of number of the station. The algorithms for culculation of stationary distributions and the loss probabilities associated with the tandem are given.

  5. A tandem queue with delayed server release

    NARCIS (Netherlands)

    Nawijn, W.M.

    1997-01-01

    We consider a tandem queue with two stations. The rst station is an s-server queue with Poisson arrivals and exponential service times. After terminating his service in the rst station, a customer enters the second station to require service at an exponential single server, while in the meantime he

  6. The PSI/ETH tandem accelerator facility

    Energy Technology Data Exchange (ETDEWEB)

    Synal, H.A.; Doebeli, M.; Fuhrmann, H.; Kubik, P.W.; Nebiker, P.W. [Paul Scherrer Inst. (PSI), Villigen (Switzerland)] [and others

    1997-09-01

    The 1996 operation of the PSI/ETH tandem accelerator at ETH Hoenggerberg is summarised with a detailed compilation of the beam time statistics and the statistics of AMS samples for the different radioisotopes and for the major fields of research. (author) 2 tab.

  7. Optimal dispatching in a tandem queue

    NARCIS (Netherlands)

    van Leeuwen, D.; Núñez Queija, R.

    2017-01-01

    We investigate a Markovian tandem queueing model in which service to the first queue is provided in batches. The main goal is to choose the batch sizes so as to minimize a linear cost function of the mean queue lengths. This model can be formulated as a Markov Decision Process (MDP) for which the

  8. Tandem queue with server slow-down

    NARCIS (Netherlands)

    Miretskiy, D.I.; Scheinhardt, W.R.W.; Mandjes, M.R.H.

    2007-01-01

    We study how rare events happen in the standard two-node tandem Jackson queue and in a generalization, the socalled slow-down network, see [2]. In the latter model the service rate of the first server depends on the number of jobs in the second queue: the first server slows down if the amount of

  9. Modelling of tandem cell temperature coefficients

    Energy Technology Data Exchange (ETDEWEB)

    Friedman, D.J. [National Renewable Energy Lab., Golden, CO (United States)

    1996-05-01

    This paper discusses the temperature dependence of the basic solar-cell operating parameters for a GaInP/GaAs series-connected two-terminal tandem cell. The effects of series resistance and of different incident solar spectra are also discussed.

  10. In situ detection of tandem DNA repeat length

    Energy Technology Data Exchange (ETDEWEB)

    Yaar, R.; Szafranski, P.; Cantor, C.R.; Smith, C.L. [Boston Univ., MA (United States)

    1996-11-01

    A simple method for scoring short tandem DNA repeats is presented. An oligonucleotide target, containing tandem repeats embedded in a unique sequence, was hybridized to a set of complementary probes, containing tandem repeats of known lengths. Single-stranded loop structures formed on duplexes containing a mismatched (different) number of tandem repeats. No loop structure formed on duplexes containing a matched (identical) number of tandem repeats. The matched and mismatched loop structures were enzymatically distinguished and differentially labeled by treatment with S1 nuclease and the Klenow fragment of DNA polymerase. 7 refs., 4 figs.

  11. Annual report of the Tandem Accelerator Center, University of Tsukuba

    International Nuclear Information System (INIS)

    1985-01-01

    This annual report covers the work carried out at the Tandem Accelerator Center, University of Tsukuba, during fiscal year 1984. The 12 UD Pelletron tandem accelerator was operated very stably. In addition, the heavy ion post accelerator with interdigital-H structure has worked well, providing additional energy of 2 MeV per charge for heavy ions. The constructions of a new Lamb-shift polarized ion source, a multi-computer control system for the ion sources of the UTTA, an electrostatic inflection system of incident ions for the UTTA, a new beam bunching system, and a new SF 6 gas handling system were under way. The development and performance test of various radiation detector systems were carried out. Two thirds of the research works were performed by using the beam from the Lamb-shift polarized ion source (PIS). A newly constructed fast spin state interchange control system for the PIS made polarization experiment more effective and accurate. The research activities in the fields of nuclear physics, atomic and solid state physics, and biology and medical science are reported. (Kako, I.)

  12. Hydrodynamic studies on two traveling wavy foils in tandem arrangement

    Science.gov (United States)

    Deng, Jian; Shao, Xue-Ming; Yu, Zhao-Sheng

    2007-11-01

    In this study, the hydrodynamic interactions between two tandem foils undergoing fishlike swimming motion are investigated numerically by solving the Navier-Stokes equations with the immersed-boundary method. The two foils represent two tandem propellers attached on a concept ship. The thrusts and efficiencies at three typical Strouhal numbers, i.e., St =0.4, 0.6, and 0.8, are investigated. The results show that a fish situated directly behind another one does not always undergo a lower thrust. Whether it experiences a thrust enhancement or reduction depends on the Strouhal number. At a relatively low Strouhal number (e.g., St =0.4), the usual wake drag-reduction effect predominates over the drag-enhancement effect caused by the reverse von Kármán vortices, resulting in a thrust enhancement. The opposite happens at a relatively high Strouhal number (e.g., St =0.8). The downstream fish can benefit from the upstream one by slalom between the vortices rather than through them. For the upstream fish, the thrusts and efficiencies for all Strouhal numbers studied are higher than those for a single fish when the two fish are closely spaced, and approach those for a single fish as the spacing is increased.

  13. Operation of the tandem-linac accelerator

    International Nuclear Information System (INIS)

    Anon.

    1985-01-01

    The tandem-linac accelerator system is operated as a source of energetic heavy-ion projectiles for research in several areas of nuclear physics and occasionally in other areas of science. The accelerator system consists of a 9-MV tandem electrostatic accelerator and a superconducting-linac energy booster that can provide an additional 20 MV of acceleration. A figure shows the layout of this system, which will be operated in its present form until September 1985, when it will be incorporated into the larger ATLAS system. In both the present and future forms the accelerator is designed to provide the exceptional beam quality and overall versatility required for precision nuclear-structure research

  14. Moment approach to tandem mirror radial transport

    International Nuclear Information System (INIS)

    Siebert, K.D.; Callen, J.D.

    1986-02-01

    A moment approach is proposed for the study of tandem mirror radial transport in the resonant plateau regime. The salient features of the method are described with reference to axisymmetric tokamak transport theory. In particular, the importance of momentum conservation to the establishment of the azimuthal variations in the electrostatic potential is demonstrated. Also, an ad hoc drift kinetic equation is solved to determine parallel viscosity coefficients which are required to close the moment system

  15. Designs of tandem-mirror fusion reactors

    International Nuclear Information System (INIS)

    Carlson, G.A.; Barr, W.L.; Boghosian, B.M.

    1981-01-01

    We have completed a comparative evaluation of several end plug configurations for tandem mirror fusion reactors with thermal barriers. The axi-cell configuration has been selected for further study and will be the basis for a detailed conceptual design study to be carried out over the next two years. The axi-cell end plug has a simple mirror cell produced by two circular coils followed by a transition coil and a yin-yang pair, which provides for MHD stability

  16. Cold Climate Heat Pumps Using Tandem Compressors

    Energy Technology Data Exchange (ETDEWEB)

    Shen, Bo [ORNL; Abdelaziz, Omar [ORNL; Rice, C Keith [ORNL; Baxter, Van D [ORNL

    2016-01-01

    In cold climate zones, e.g. ASHRAE climate regions IV and V, conventional electric air-source heat pumps (ASHP) do not work well, due to high compressor discharge temperatures, large pressure ratios and inadequate heating capacities at low ambient temperatures. Consequently, significant use of auxiliary strip heating is required to meet the building heating load. We introduce innovative ASHP technologies as part of continuing efforts to eliminate auxiliary strip heat use and maximize heating COP with acceptable cost-effectiveness and reliability. These innovative ASHP were developed using tandem compressors, which are capable of augmenting heating capacity at low temperatures and maintain superior part-load operation efficiency at moderate temperatures. Two options of tandem compressors were studied; the first employs two identical, single-speed compressors, and the second employs two identical, vapor-injection compressors. The investigations were based on system modeling and laboratory evaluation. Both designs have successfully met the performance criteria. Laboratory evaluation showed that the tandem, single-speed compressor ASHP system is able to achieve heating COP = 4.2 at 47 F (8.3 C), COP = 2.9 at 17 F (-8.3 C), and 76% rated capacity and COP = 1.9 at -13 F (-25 C). This yields a HSPF = 11.0 (per AHRI 210/240). The tandem, vapor-injection ASHP is able to reach heating COP = 4.4 at 47 F, COP = 3.1 at 17 F, and 88% rated capacity and COP = 2.0 at -13 F. This yields a HSPF = 12.0. The system modeling and further laboratory evaluation are presented in the paper.

  17. The Influence of the Phase Difference between the Crank Angle of the Pilot and that of the Stoker on the Drag Acting on a Tandem Bike

    Directory of Open Access Journals (Sweden)

    Kazuya Seo

    2018-02-01

    Full Text Available Two wind tunnel experiments were carried out to investigate the drag acting on a tandem bike. One experiment involved measurement of the drag acting on two full-scale human models on a tandem. These two human models can pedal the tandem. In the other experiment, two oscillating cylinders were used as a simplified model of the legs of the pilot and the stoker. These were arranged to represent the legs of the riders on a tandem. Measurements of the drag on this model were made. It was found that the drag decreases when the crank angle of the stoker’s pedal is delayed with respect to the pilot’s pedal.

  18. TandEM: Titan and Enceladus mission

    Science.gov (United States)

    Coustenis, A.; Atreya, S.K.; Balint, T.; Brown, R.H.; Dougherty, M.K.; Ferri, F.; Fulchignoni, M.; Gautier, D.; Gowen, R.A.; Griffith, C.A.; Gurvits, L.I.; Jaumann, R.; Langevin, Y.; Leese, M.R.; Lunine, J.I.; McKay, C.P.; Moussas, X.; Muller-Wodarg, I.; Neubauer, F.; Owen, T.C.; Raulin, F.; Sittler, E.C.; Sohl, F.; Sotin, Christophe; Tobie, G.; Tokano, T.; Turtle, E.P.; Wahlund, J.-E.; Waite, J.H.; Baines, K.H.; Blamont, J.; Coates, A.J.; Dandouras, I.; Krimigis, T.; Lellouch, E.; Lorenz, R.D.; Morse, A.; Porco, C.C.; Hirtzig, M.; Saur, J.; Spilker, T.; Zarnecki, J.C.; Choi, E.; Achilleos, N.; Amils, R.; Annan, P.; Atkinson, D.H.; Benilan, Y.; Bertucci, C.; Bezard, B.; Bjoraker, G.L.; Blanc, M.; Boireau, L.; Bouman, J.; Cabane, M.; Capria, M.T.; Chassefiere, E.; Coll, P.; Combes, M.; Cooper, J.F.; Coradini, A.; Crary, F.; Cravens, T.; Daglis, I.A.; de Angelis, E.; De Bergh, C.; de Pater, I.; Dunford, C.; Durry, G.; Dutuit, O.; Fairbrother, D.; Flasar, F.M.; Fortes, A.D.; Frampton, R.; Fujimoto, M.; Galand, M.; Grasset, O.; Grott, M.; Haltigin, T.; Herique, A.; Hersant, F.; Hussmann, H.; Ip, W.; Johnson, R.; Kallio, E.; Kempf, S.; Knapmeyer, M.; Kofman, W.; Koop, R.; Kostiuk, T.; Krupp, N.; Kuppers, M.; Lammer, H.; Lara, L.-M.; Lavvas, P.; Le, Mouelic S.; Lebonnois, S.; Ledvina, S.; Li, Ji; Livengood, T.A.; Lopes, R.M.; Lopez-Moreno, J. -J.; Luz, D.; Mahaffy, P.R.; Mall, U.; Martinez-Frias, J.; Marty, B.; McCord, T.; Salvan, C.M.; Milillo, A.; Mitchell, D.G.; Modolo, R.; Mousis, O.; Nakamura, M.; Neish, Catherine D.; Nixon, C.A.; Mvondo, D.N.; Orton, G.; Paetzold, M.; Pitman, J.; Pogrebenko, S.; Pollard, W.; Prieto-Ballesteros, O.; Rannou, P.; Reh, K.; Richter, L.; Robb, F.T.; Rodrigo, R.; Rodriguez, S.; Romani, P.; Bermejo, M.R.; Sarris, E.T.; Schenk, P.; Schmitt, B.; Schmitz, N.; Schulze-Makuch, D.; Schwingenschuh, K.; Selig, A.; Sicardy, B.; Soderblom, L.; Spilker, L.J.; Stam, D.; Steele, A.; Stephan, K.; Strobel, D.F.; Szego, K.; Szopa,

    2009-01-01

    TandEM was proposed as an L-class (large) mission in response to ESA’s Cosmic Vision 2015–2025 Call, and accepted for further studies, with the goal of exploring Titan and Enceladus. The mission concept is to perform in situ investigations of two worlds tied together by location and properties, whose remarkable natures have been partly revealed by the ongoing Cassini–Huygens mission. These bodies still hold mysteries requiring a complete exploration using a variety of vehicles and instruments. TandEM is an ambitious mission because its targets are two of the most exciting and challenging bodies in the Solar System. It is designed to build on but exceed the scientific and technological accomplishments of the Cassini–Huygens mission, exploring Titan and Enceladus in ways that are not currently possible (full close-up and in situ coverage over long periods of time). In the current mission architecture, TandEM proposes to deliver two medium-sized spacecraft to the Saturnian system. One spacecraft would be an orbiter with a large host of instruments which would perform several Enceladus flybys and deliver penetrators to its surface before going into a dedicated orbit around Titan alone, while the other spacecraft would carry the Titan in situ investigation components, i.e. a hot-air balloon (Montgolfière) and possibly several landing probes to be delivered through the atmosphere.

  19. ORNL 25 MV tandem accelerator control system

    International Nuclear Information System (INIS)

    Juras, R.C.; Biggerstaff, J.A.; Hoglund, D.E.

    1985-01-01

    The CAMAC-based control system for the 25 MV tandem electrostatic accelerator of the Holifield Heavy Ion Research Facility at Oak Ridge National Laboratory (ORNL) was specified by ORNL and built by the National Electrostatics Corporation. Two Perkin-Elmer 32-bit minicomputers are used in the system, a message switching computer and a supervisory computer. The message switching computer transmits and receives control information on six serial highways. This computer shares memory with the supervisory computer. Operator consoles are located on a serial highway; control is by means of a console CRT, trackball, and assignable shaft encoders and meters. Two identical consoles operate simultaneously: one is located in the tandem control room; the other is located in the cyclotron control room to facilitate operation during injection of tandem beams into the cyclotron or when beam lines under control of the cyclotron control system are used. The supervisory computer is used for accelerator parameter setup calculations, actual accelerator setup for new beams based on scaled, recorded parameters from previously run beams, and various other functions. Nearly seven years of control system operation and improvements will be discussed

  20. Thermodynamic characterization of tandem mismatches found in naturally occurring RNA

    Science.gov (United States)

    Christiansen, Martha E.; Znosko, Brent M.

    2009-01-01

    Although all sequence symmetric tandem mismatches and some sequence asymmetric tandem mismatches have been thermodynamically characterized and a model has been proposed to predict the stability of previously unmeasured sequence asymmetric tandem mismatches [Christiansen,M.E. and Znosko,B.M. (2008) Biochemistry, 47, 4329–4336], experimental thermodynamic data for frequently occurring tandem mismatches is lacking. Since experimental data is preferred over a predictive model, the thermodynamic parameters for 25 frequently occurring tandem mismatches were determined. These new experimental values, on average, are 1.0 kcal/mol different from the values predicted for these mismatches using the previous model. The data for the sequence asymmetric tandem mismatches reported here were then combined with the data for 72 sequence asymmetric tandem mismatches that were published previously, and the parameters used to predict the thermodynamics of previously unmeasured sequence asymmetric tandem mismatches were updated. The average absolute difference between the measured values and the values predicted using these updated parameters is 0.5 kcal/mol. This updated model improves the prediction for tandem mismatches that were predicted rather poorly by the previous model. This new experimental data and updated predictive model allow for more accurate calculations of the free energy of RNA duplexes containing tandem mismatches, and, furthermore, should allow for improved prediction of secondary structure from sequence. PMID:19509311

  1. An RF heated tandem mirror plasma propulsion study

    Science.gov (United States)

    Yang, T. F.; Yao, X.; Peng, S.; Krueger, W. A.; Chang-Diaz, F. R.

    1989-01-01

    Experimental results on a tandem mirror hybrid plume rocket involving a three-stage system of plasma injection, heating, and subsequent injection through a magnetic nozzle are presented. In the experiments, a plasma is created by breaking down the gas with electron cyclotron resonance heating at 2 kW in the central cell, and the ion species is then heated to high temperatures with ion cyclotron resonance heating at 10 kW in the end cell. A Langmuir probe measured an electron density of 2.5 x 10 to the 16th/cu m and a temperature of 100 eV in the central cell and an ion density of 1.25 x 10 to the 17th/cu m and a temperature of 500 eV in the end cell.

  2. Actualization of the Tandem-E N Accelerator of the Nuclear Centre of Mexico

    International Nuclear Information System (INIS)

    Villasenor S, P.; Aguilera R, E.; Aspiazu F, J.; Fernandez A, J.; Fernandez B, M.; Garcia R, B.; Lopez M, J.; Martinez Q, E.; Mendez G, B.; Moreno B, E.; Murillo O, G.; Policroniades R, R.; Ramirez T, J.; Reynoso V, R.; Varela G, A.; Vega C, J.

    2004-01-01

    In this work, the activities are described carried out to change the tubes accelerators and original resistances of the accelerator Tandem-E N of the Nuclear Center, for tubes DOWLISH and resistances again design, both donated ones for ORNL. This way same, the problem is described that imply this changes, and like it was solved by the personnel of the laboratory, without having to appeal to external services, what there is redounded in a considerable increment in the costs. In form preliminary the improvements are described observed after the rehabilitation of the Accelerator. (Author)

  3. Experiments related to marine environmental science using a tandem Pelletron

    International Nuclear Information System (INIS)

    Kitamura, A.; Hamamoto, S.; Ohtani, Y.; Furuyama, Y.; Taniike, A.; Kubota, N.; Yamauchi, T.; Mimura, H.

    2003-01-01

    Activities related to marine environmental science, which have been made in our laboratory using a 1.7MV Pelletron 5SDH2 accelerator, are reviewed. One is successful application of proton beams to radiation-induced graft polymerization for making amidoxime-type adsorbents that are very effective for collecting doubly charged ions of metal elements, such as uranium and vanadium, abundantly dissolved in seawater. The other is effective application of accelerator analyses to investigation of interaction of tributyltin (TBT) chloride, which had been used in self-polishing antifouling paints and are endocrine disrupter having mutagenicity, with a TBT resistant marine microorganism newly isolated from sediment of a ship's ballast water tank. (author)

  4. Modeling of ICRH experiments in the Tara tandem mirror

    International Nuclear Information System (INIS)

    Myer, R.C.; Golovato, S.N.

    1987-01-01

    The production and heating of the central cell plasma in Tara is provided by a slot antenna located on the midplane bump of the axial magnetic field profile. Slow ion cyclotron waves excited by the slot propagate down a magnetic beach to ion cyclotron resonance layers located on either side of the bump where the RF power is strongly damped by the ions. Two different theoretical models are being used to study the efficiency of coupling to slow waves in this configuration. Wave propagation models which are based on the infinite plasma dispersion relation for a cold plasma indicate that radially propagating left hand polarized slow waves are converted to right hand polarized fast waves at the Alfven resonance layer due to the radial density gradient. If this were to occur we would expect a lower coupling efficiency to the ions in the plasma core. On the other hand, a nonlocal kinetic model of RF wave propagation in a nonuniform plasma slab indicates that significant left hand component of the electric field extends beyond the Alfven resonance layer. Preliminary experimental measurements of the radial inductive field profile agree qualitatively with the predictions of the cold plasma model, however, there is insufficient data at this time time to establish that a density limit for slow wave accessibility to the plasma core exists

  5. Modeling of ICRH experiments in the Tara tandem mirror

    International Nuclear Information System (INIS)

    Myer, R.C.; Golovato, S.N.

    1987-05-01

    The production and heating of the central cell plasma in Tara are provided by a slot antenna located on the midplane bump of the axial magnetic field profile. Slow ion cyclotron waves excited by the slot propagate down a magnetic beach to ion cyclotron resonance layers located on either side of the bump where the rf power is strongly damped by the ions. Two different theoretical models are being used to study the efficiency of coupling to slow waves in this configuration. Wave propagation models which are based on the infinite plasma dispersion relation for a cold plasma indicate that radially propagating left hand polarized slow waves are converted to right hand polarized fast waves at the Alfven resonance layer due to the radial density gradient. If this were to occur we would expect a lower coupling efficiency to the ions in the plasma core. On the other hand, a nonlocal kinetic model of rf wave propagation in a nonuniform plasma slab indicates that a significant left hand component of the electric field extends beyond the Alfven resonance layer. Preliminary experimental measurements of the radial inductive field profile agree qualitatively with the predictions of the cold plasma model, however, there is insufficient data at this time to establish that a density limit for slow wave accessibility to the plasma core exists

  6. Present status of tandem accelerator in Japan Atomic Energy Research Institute

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida, Tadashi; Kanda, Susumu; Takeuchi, Suehiro [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1996-12-01

    The tandem accelerator in Japan Atomic Energy Research Institute was made by NEC in USA. Since it is the accelerator of turning-up structure, it has large magnet at the high voltage terminal, and supplies electric power by driving a generator with large diameter shaft. The control is carried out by CAMUCK, and the electronic circuit is protected from the surging arising due to discharge. Since the experiment on full scale was begun, 14 years have elapsed, and at present, it became a very stable accelerator. As to the operation mode, the acceleration voltage is limited to below 17 MV. The operation voltage and the state of operation are shown. Recently, the troubles of chains originating in oil have occurred. The adjustment of the tandem accelerator requires more than one month. The adjustment is mainly related to the chains and shafts, and this is explained. The ion source used for the tandem accelerator at present is the negative ion source made by NEC. The installation of an ECR ion source is planned. The utilization of the tandem accelerator system is reported. (K.I.)

  7. Flexible and fragmentable tandem photosensitive nanocrystal skins

    Science.gov (United States)

    Akhavan, S.; Uran, C.; Bozok, B.; Gungor, K.; Kelestemur, Y.; Lesnyak, V.; Gaponik, N.; Eychmüller, A.; Demir, H. V.

    2016-02-01

    We proposed and demonstrated the first account of large-area, semi-transparent, tandem photosensitive nanocrystal skins (PNSs) constructed on flexible substrates operating on the principle of photogenerated potential buildup, which avoid the need for applying an external bias and circumvent the current-matching limitation between junctions. We successfully fabricated and operated the tandem PNSs composed of single monolayers of colloidal water-soluble CdTe and CdHgTe nanocrystals (NCs) in adjacent junctions on a Kapton polymer tape. Owing to the usage of a single NC layer in each junction, noise generation was significantly reduced while keeping the resulting PNS films considerably transparent. In each junction, photogenerated excitons are dissociated at the interface of the semi-transparent Al electrode and the NC layer, with holes migrating to the contact electrode and electrons trapped in the NCs. As a result, the tandem PNSs lead to an open-circuit photovoltage buildup equal to the sum of those of the two single junctions, exhibiting a total voltage buildup of 128.4 mV at an excitation intensity of 75.8 μW cm-2 at 350 nm. Furthermore, we showed that these flexible PNSs could be bent over 3.5 mm radius of curvature and cut out in arbitrary shapes without damaging the operation of individual parts and without introducing any significant loss in the total sensitivity. These findings indicate that the NC skins are promising as building blocks to make low-cost, flexible, large-area UV/visible sensing platforms with highly efficient full-spectrum conversion.We proposed and demonstrated the first account of large-area, semi-transparent, tandem photosensitive nanocrystal skins (PNSs) constructed on flexible substrates operating on the principle of photogenerated potential buildup, which avoid the need for applying an external bias and circumvent the current-matching limitation between junctions. We successfully fabricated and operated the tandem PNSs composed of

  8. First operation of ATLAS using the PII linac and a comparison to tandem injection

    International Nuclear Information System (INIS)

    Pardo, R.C.; Bollinger, L.M.; Billquist, P.J.; Bogaty, J.M.; Clifft, B.E.; Markovich, P.; Munson, F.H.; Shepard, K.W.; Zinkann, G.P.

    1991-01-01

    The ATLAS Positive Ion Injector (PII) is designed to replace the tandem injector for the ATLAS heavy-ion facility. When the PII project is complete, ATLAS will be able to accelerate all ions through uranium to energies above the Coulomb barrier. PII consists of an ECR ion source on a 350 kV platform and a very low-velocity superconducting linac. The PII project is nearing completion. First beam from the complete system is expected in early 1992. Beam tests and experiments using a partially completed PII linac have demonstrated that the technical design goals are being met. The results of the early beam tests and first experiments will be discussed and compared to the performance of ATLAS with tandem injection. 10 refs., 2 figs

  9. First operation of ATLAS using the PII linac and a comparison to tandem injection

    Energy Technology Data Exchange (ETDEWEB)

    Pardo, R.C.; Bollinger, L.M.; Billquist, P.J.; Bogaty, J.M.; Clifft, B.E.; Markovich, P.; Munson, F.H.; Shepard, K.W.; Zinkann, G.P.

    1991-12-31

    The ATLAS Positive Ion Injector (PII) is designed to replace the tandem injector for the ATLAS heavy-ion facility. When the PII project is complete, ATLAS will be able to accelerate all ions through uranium to energies above the Coulomb barrier. PII consists of an ECR ion source on a 350 kV platform and a very low-velocity superconducting linac. The PII project is nearing completion. First beam from the complete system is expected in early 1992. Beam tests and experiments using a partially completed PII linac have demonstrated that the technical design goals are being met. The results of the early beam tests and first experiments will be discussed and compared to the performance of ATLAS with tandem injection. 10 refs., 2 figs.

  10. First operation of ATLAS using the PII linac and a comparison to tandem injection

    Energy Technology Data Exchange (ETDEWEB)

    Pardo, R.C.; Bollinger, L.M.; Billquist, P.J.; Bogaty, J.M.; Clifft, B.E.; Markovich, P.; Munson, F.H.; Shepard, K.W.; Zinkann, G.P.

    1991-01-01

    The ATLAS Positive Ion Injector (PII) is designed to replace the tandem injector for the ATLAS heavy-ion facility. When the PII project is complete, ATLAS will be able to accelerate all ions through uranium to energies above the Coulomb barrier. PII consists of an ECR ion source on a 350 kV platform and a very low-velocity superconducting linac. The PII project is nearing completion. First beam from the complete system is expected in early 1992. Beam tests and experiments using a partially completed PII linac have demonstrated that the technical design goals are being met. The results of the early beam tests and first experiments will be discussed and compared to the performance of ATLAS with tandem injection. 10 refs., 2 figs.

  11. Some new ideas for Tandem Mirror blankets

    International Nuclear Information System (INIS)

    Neef, W.S. Jr.

    1981-01-01

    The Tandem Mirror Reactor, with its cylindrical central cell, has led to numerous blanket designs taking advantage of the simple geometry. Also many new applications for fusion neutrons are now being considered. To the pure fusion electricity producers and hybrids producing fissile fuel, we are adding studies of synthetic fuel producers and fission-suppressed hybrids. The three blanket concepts presented are new ideas and should be considered illustrative of the breadth of Livermore's application studies. They are not meant to imply fully analyzed designs

  12. Tandem mirror and tokamak reactor maintainability comparison

    International Nuclear Information System (INIS)

    Zahn, H.S.

    1981-01-01

    The analysis proceeds through estimates of downtime and resources required for selected maintenance actions and optimization of the replacement fraction, availability and cost of electricity. Scheduled downtime estimates and availability goals provide a basis for determining allowable forced outage downtimes. These analyses have been conducted with the assumption of redundancy wherever feasible but without the impact of maintenance equipment outages. Annual maintenance cost estimates and availabilities for both reactors are found to be approximately equal. However, the tandem mirror reactor capital costs are higher. Reduction of these costs appears feasible with the trend of current design studies toward smaller and more accessible machines

  13. Parametric systems analysis for tandem mirror hybrids

    International Nuclear Information System (INIS)

    Lee, J.D.; Chapin, D.L.; Chi, J.W.H.

    1980-09-01

    Fusion fission systems, consisting of fissile producing fusion hybrids combining a tandem mirror fusion driver with various blanket types and net fissile consuming LWR's, have been modeled and analyzed parametrically. Analysis to date indicates that hybrids can be competitive with mined uranium when U 3 O 8 cost is about 100 $/lb., adding less than 25% to present day cost of power from LWR's. Of the three blanket types considered, uranium fast fission (UFF), thorium fast fission (ThFF), and thorium fission supressed (ThFS), the ThFS blanket has a modest economic advantage under most conditions but has higher support ratios and potential safety advantages under all conditions

  14. NSF tandem stack support structure deflection characteristics

    International Nuclear Information System (INIS)

    Cook, J.

    1979-12-01

    Results are reported of load tests carried out on the glass legs of the insulating stack of the 30 MV tandem Van de Graaff accelerator now under construction at Daresbury Laboratory. The tests to investigate the vulnerability of the legs when subjected to tensile stresses were designed to; establish the angle of rotation of the pads from which the stresses in the glass legs may be calculated, proof-test the structure and at the same time reveal any asymmetry in pad rotations or deflections, and to confirm the validity of the computer design analysis. (UK)

  15. A tandem queue with delayed server release

    OpenAIRE

    Nawijn, W.M.

    1997-01-01

    We consider a tandem queue with two stations. The rst station is an s-server queue with Poisson arrivals and exponential service times. After terminating his service in the rst station, a customer enters the second station to require service at an exponential single server, while in the meantime he is blocking his server in station 1 until he completes service in station 2, whereupon the server in station 1 is released. An analysis of the generating function of the simultaneous probability di...

  16. Negative ion sources for tandem accelerator

    International Nuclear Information System (INIS)

    Minehara, Eisuke

    1980-08-01

    Four kinds of negative ion sources (direct extraction Duoplasmatron ion source, radial extraction Penniing ion source, lithium charge exchange ion source and Middleton-type sputter ion source) have been installed in the JAERI tandem accelerator. The ion sources can generate many negative ions ranging from Hydrogen to Uranium with the exception of Ne, Ar, Kr, Xe and Rn. Discussions presented in this report include mechanisms of negative ion formation, electron affinity and stability of negative ions, performance of the ion sources and materials used for negative ion production. Finally, the author will discuss difficult problems to be overcome in order to get any negative ion sufficiently. (author)

  17. Tandem Carbocupration/Oxygenation of Terminal Alkynes

    Science.gov (United States)

    Zhang, Donghui; Ready, Joseph M.

    2008-01-01

    A direct and general synthesis of α-branched aldehydes and their enol derivatives is described. Carbocupration of terminal alkynes and subsequent oxygenation with lithium tert-butyl peroxide generates a metallo-enolate. Trapping with various electrophiles provides α-branched aldehydes or stereo-defined trisubstituted enol esters or silyl ethers. The tandem carbocupration/oxygenation tolerates alkyl and silyl ethers, esters and tertiary amines. The reaction is effective with organocopper complexes derived from primary, secondary and tertiary Grignard reagents and from n-butyllithium. PMID:16321021

  18. Beam trajectories through the upgraded XTU tandem

    International Nuclear Information System (INIS)

    Guan Xialing

    1988-01-01

    The paper deals with a problem applicable to all electrostatic accelerators with inclined field accelerating tubes, how the trajectory of the central beam particle is affected if one of the accelerating gaps must be shorted out due to insulator failure. For the long tube of the Legnaro XTU tandem the effect of each accelerator gap is calculated and a method of compensation either by shorting out an appropriate gap with reversed incline or by appropriately steering the beam into the entrance of the low energy tube is given. (orig.)

  19. TANDEM - French-German cooperation for local energy transition

    International Nuclear Information System (INIS)

    Mouchard, Claire; Garreau, Enora; Maurer, Christiane; Schilken, Peter; Keilmann, Jenny-Claire; Janssen, Ulrike

    2014-01-01

    The simultaneous implementation of the German 'Energiewende' and the French 'Transition energetique' prompted both country's governments to sign various cooperation agreements. As both 'Energiewende' and 'Transition energetique' put a strong focus on decentralization of energy supply, establishing close inter-communal cooperation is particularly promising. The project TANDEM, which is jointly led by Klima-Buendnis and Energy Cities - both local authority networks - and co-funded by Germany's Federal Environment Agency (UBA) and the French Energy Agency ADEME provides French and German local authorities with a unique opportunity to exchange experiences and create partnerships for climate protection having the following objectives: - Creating broad mutual understanding for the respective situation, challenges and framework in energy and climate policy; - Encourage exchanges with regard to obstacles and success factors concerning the realization of ambitious energy- and climate-goals and promoting mutual transfer of know-how; - Stimulating close collaboration between local authorities from both countries while involving and supporting local stakeholders and citizens; - Implementing initial stages of cooperation projects during the lifetime of the TANDEM project and creating a foundation for long-term cooperation; - Raise awareness for demands, requirements and concerns of local authorities on a national and European level in order to strengthen their influence and enlarge their scope of action. In this document, the authors briefly present the French, German and European contexts and the organization of both countries regarding energy transition. Then, a parallel is made between the national energy-climate plans of both countries ('Klimaschutzkonzepte' and 'Plans Climat-Energie Territoriaux') to identify the similarities and differences in order to learn from each other and to be able to create cooperations between both policy mechanisms

  20. Radioisotope detection with tandem electrostatic accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Gove, H E; Elmore, D; Ferraro, R [Rochester Univ., NY (USA). Nuclear Structure Research Lab.; Beukens, R P; Chang, K H; Kilius, L R; Lee, H W; Litherland, A E [Toronto Univ., Ontario (Canada). Dept. of Physics; Purser, K H [General Ionex Corp., Newburyport, MA (USA)

    1980-01-01

    An MP tandem Van de Graaff accelerator at the University of Rochester has been employed since May 1977 to detect /sup 14/C in terrestrial samples, /sup 36/Cl in terrestrial and extraterrestrial samples and /sup 10/Be and /sup 26/Al in samples produced by reactor and accelerator irradiation. The sample sizes ranged from about 10 to less than 1 mg and the ratio of the radioisotope to the stable isotopes approached one part in 10/sup 16/ for /sup 14/C and /sup 36/Cl and one part in 10/sup 14/ for /sup 10/Be and /sup 26/Al. /sup 14/C has been measured in a number of samples of geological and archaelogical interest. /sup 36/Cl has been measured in various groundwater samples as well as samples at Antarctic meteorites and ice. Dedicated systems for /sup 14/C dating and geological measurements based on the tandem electrostatic accelerator principle are presently under construction for laboratories in the U.S.A., U.K. and Canada.

  1. Remote maintenance of tandem mirror hybrid coils

    International Nuclear Information System (INIS)

    Dietz, L.P.

    1983-01-01

    Hybrid Coils (superconducting coils with normal conducting inserts) are being employed with increasing frequency on Tandem Mirror Devices to obtain high field strengths. The normal conducting copper inserts are short lived in comparison to their encircling superconductors. It becomes desirable, therefore, to devise design features and maintenance procedures to replace the inner normal conducting coils without simultaneously replacing the longer lived (and significantly more costly) superconducting coils. The high neutron wall loadings require that the task be accomplished by remote control. The approach is to permanently mount the coil assemblies on track mounted carriages which serve, during machine operation merely as structural supports, but during maintenance procedures as moveable transport devices. The carriages incorporate all necessary provisions to facilitate remote maintenance operations and to adjust and align the coil assemblies with respect to adjacent machine components. The vacuum vessel is severed on both sides of the hybrid coil by means of a remote cutting machine. The entire coil is transported horizontally, normal to the machine axis to a nearby repair station. Prepositioned carriage mounted repair equipment at the repair station withdraws the damaged normal coil as a single entity and inserts a preassembled spare unit. The repaired hybrid coil is reassembled to the reactor. A cost and risk effective procedure has been evolved to maintain one of the more critical components of a Tandem Mirror Machine

  2. Recent improvements of the tandem facility at LNS

    International Nuclear Information System (INIS)

    Ciavola, G.; Calabretta, L.; Cuttone, G.; Gammino, S.; Raia, G.; Rifuggiato, D.; Rovelli, A.; Scuderi, V.

    1993-01-01

    The Laboratorio Nazionale del Sud (LNS) of Catania is equipped with an upgraded 15 MV SMP tandem that is going to be coupled to a k=800 superconducting cyclotron. The status of the facility and the performances of the upgraded tandem are presented. (orig.)

  3. Status report on the folded tandem ion accelerator at BARC

    Indian Academy of Sciences (India)

    Folded tandem ion accelerator; charged particle beams; voltage stability; Rutherford backscattering; ion optics; beam lines. Abstract. The folded tandem ion accelerator (FOTIA) facility set up at BARC has become operational. At present, it is used for elemental analysis studies using the Rutherford backscattering technique.

  4. High-sensitivity mass spectrometry with a tandem accelerator

    International Nuclear Information System (INIS)

    Henning, W.

    1984-01-01

    The characteristic features of accelerator mass spectrometry are discussed. A short overview is given of the current status of mass spectrometry with high-energy (MeV/nucleon) heavy-ion accelerators. Emphasis is placed on studies with tandem accelerators and on future mass spectrometry of heavier isotopes with the new generation of higher-voltage tandems

  5. Performance analysis of tandem queues with small buffers

    NARCIS (Netherlands)

    Vuuren, van M.; Adan, I.J.B.F.; Papadopoulos, C.T.

    2005-01-01

    In this paper we present an approximation for the performance analysis of single-server tandem queues with small buffers and generally distributed service times. The approximation is based on decomposition of the tandem queue in subsystems, the parameters of which are determined by an iterative

  6. A solution process for inverted tandem solar cells

    DEFF Research Database (Denmark)

    Larsen-Olsen, Thue Trofod; Bundgaard, Eva; Sylvester-Hvid, Kristian O.

    2011-01-01

    Tandem solar cells with normal and inverted device geometries were prepared by a solution process. Both device types were based on the use of zinc(II)oxide as the electron transporting layer (ETL). The hole transporting layer (HTL) was either PEDOT:PSS for normal geometry tandem solar cells...... or vanadium(V)oxide in the case of inverted tandem cells. It was found that the inverted tandem solar cells performed comparable or better than the normal geometry devices, showing that the connection structure of vanadium(V)oxide, Ag nanoparticles and zinc(II)oxide functions both as a good recombination...... layer, ensuring serial connection, and as a solvent barrier, protecting the first photoactive layer from processing of the second layer. This successfully demonstrates a tandem solar cell fabrication process fully compatible with state-of-the-art solution based automated production procedures....

  7. Solution Structure of the Tandem Acyl Carrier Protein Domains from a Polyunsaturated Fatty Acid Synthase Reveals Beads-on-a-String Configuration

    KAUST Repository

    Trujillo, Uldaeliz

    2013-02-28

    The polyunsaturated fatty acid (PUFA) synthases from deep-sea bacteria invariably contain multiple acyl carrier protein (ACP) domains in tandem. This conserved tandem arrangement has been implicated in both amplification of fatty acid production (additive effect) and in structural stabilization of the multidomain protein (synergistic effect). While the more accepted model is one in which domains act independently, recent reports suggest that ACP domains may form higher oligomers. Elucidating the three-dimensional structure of tandem arrangements may therefore give important insights into the functional relevance of these structures, and hence guide bioengineering strategies. In an effort to elucidate the three-dimensional structure of tandem repeats from deep-sea anaerobic bacteria, we have expressed and purified a fragment consisting of five tandem ACP domains from the PUFA synthase from Photobacterium profundum. Analysis of the tandem ACP fragment by analytical gel filtration chromatography showed a retention time suggestive of a multimeric protein. However, small angle X-ray scattering (SAXS) revealed that the multi-ACP fragment is an elongated monomer which does not form a globular unit. Stokes radii calculated from atomic monomeric SAXS models were comparable to those measured by analytical gel filtration chromatography, showing that in the gel filtration experiment, the molecular weight was overestimated due to the elongated protein shape. Thermal denaturation monitored by circular dichroism showed that unfolding of the tandem construct was not cooperative, and that the tandem arrangement did not stabilize the protein. Taken together, these data are consistent with an elongated beads-on-a-string arrangement of the tandem ACP domains in PUFA synthases, and speak against synergistic biocatalytic effects promoted by quaternary structuring. Thus, it is possible to envision bioengineering strategies which simply involve the artificial linking of multiple ACP

  8. Solution Structure of the Tandem Acyl Carrier Protein Domains from a Polyunsaturated Fatty Acid Synthase Reveals Beads-on-a-String Configuration

    KAUST Repository

    Trujillo, Uldaeliz; Vá zquez-Rosa, Edwin; Oyola-Robles, Delise; Stagg, Loren J.; Vassallo, David A.; Vega, Irving E.; Arold, Stefan T.; Baerga-Ortiz, Abel

    2013-01-01

    The polyunsaturated fatty acid (PUFA) synthases from deep-sea bacteria invariably contain multiple acyl carrier protein (ACP) domains in tandem. This conserved tandem arrangement has been implicated in both amplification of fatty acid production (additive effect) and in structural stabilization of the multidomain protein (synergistic effect). While the more accepted model is one in which domains act independently, recent reports suggest that ACP domains may form higher oligomers. Elucidating the three-dimensional structure of tandem arrangements may therefore give important insights into the functional relevance of these structures, and hence guide bioengineering strategies. In an effort to elucidate the three-dimensional structure of tandem repeats from deep-sea anaerobic bacteria, we have expressed and purified a fragment consisting of five tandem ACP domains from the PUFA synthase from Photobacterium profundum. Analysis of the tandem ACP fragment by analytical gel filtration chromatography showed a retention time suggestive of a multimeric protein. However, small angle X-ray scattering (SAXS) revealed that the multi-ACP fragment is an elongated monomer which does not form a globular unit. Stokes radii calculated from atomic monomeric SAXS models were comparable to those measured by analytical gel filtration chromatography, showing that in the gel filtration experiment, the molecular weight was overestimated due to the elongated protein shape. Thermal denaturation monitored by circular dichroism showed that unfolding of the tandem construct was not cooperative, and that the tandem arrangement did not stabilize the protein. Taken together, these data are consistent with an elongated beads-on-a-string arrangement of the tandem ACP domains in PUFA synthases, and speak against synergistic biocatalytic effects promoted by quaternary structuring. Thus, it is possible to envision bioengineering strategies which simply involve the artificial linking of multiple ACP

  9. Solution structure of the tandem acyl carrier protein domains from a polyunsaturated fatty acid synthase reveals beads-on-a-string configuration.

    Directory of Open Access Journals (Sweden)

    Uldaeliz Trujillo

    Full Text Available The polyunsaturated fatty acid (PUFA synthases from deep-sea bacteria invariably contain multiple acyl carrier protein (ACP domains in tandem. This conserved tandem arrangement has been implicated in both amplification of fatty acid production (additive effect and in structural stabilization of the multidomain protein (synergistic effect. While the more accepted model is one in which domains act independently, recent reports suggest that ACP domains may form higher oligomers. Elucidating the three-dimensional structure of tandem arrangements may therefore give important insights into the functional relevance of these structures, and hence guide bioengineering strategies. In an effort to elucidate the three-dimensional structure of tandem repeats from deep-sea anaerobic bacteria, we have expressed and purified a fragment consisting of five tandem ACP domains from the PUFA synthase from Photobacterium profundum. Analysis of the tandem ACP fragment by analytical gel filtration chromatography showed a retention time suggestive of a multimeric protein. However, small angle X-ray scattering (SAXS revealed that the multi-ACP fragment is an elongated monomer which does not form a globular unit. Stokes radii calculated from atomic monomeric SAXS models were comparable to those measured by analytical gel filtration chromatography, showing that in the gel filtration experiment, the molecular weight was overestimated due to the elongated protein shape. Thermal denaturation monitored by circular dichroism showed that unfolding of the tandem construct was not cooperative, and that the tandem arrangement did not stabilize the protein. Taken together, these data are consistent with an elongated beads-on-a-string arrangement of the tandem ACP domains in PUFA synthases, and speak against synergistic biocatalytic effects promoted by quaternary structuring. Thus, it is possible to envision bioengineering strategies which simply involve the artificial linking of

  10. Flying Posture of Tandem Warhead Influences its Penetrating and Following Performance

    Directory of Open Access Journals (Sweden)

    Jin-tao Wang

    2014-02-01

    Full Text Available In this study, we investigated a novel monolithic tandem penetrating-blast warhead, which can destroy targets with adjustable parameters including attack velocity, angles, as well as yaw angles. Different flying postures determine different performance of the precursory EFP in penetration process and its following projectile in secondary process. In order to characterize the influence of flying posture, we established a finite elements analysis model. This model has been verified by a static experiment. Our results indicated that the attack velocity of the warhead has tiny influence of the penetration process. However, larger attack angle of the warhead will lead to bad performance of the warhead. Meanwhile, yaw angle range should be controlled in small values due to its randomness. The comprehensive properties of the tandem warhead meet the design requirement, and it is able to damage the target effectively.

  11. Mechanical device for enhancing halo density in the TMX-U tandem mirror

    International Nuclear Information System (INIS)

    Hsu, W.L.; Barr, W.L.; Simonen, T.C.

    1984-04-01

    The halo recycler, a mechanical device similar to pumped limiters used in tokamaks, is studied as a means of enhancing the halo plasma density in the Tandem Mirror Experiment Upgrade (TMX-U). The recycler structure consists of an annular chamber at each end of the tandem mirror device where the halo plasma is collected. The halo plasma density is increased by recycling the halo ions as they are neutralized by the collector plate. With sufficient power fed into the halo electrons, the recycler can sustain an upstream electron temperature of 30 eV for effective halo shielding while maintaining a low temperature of 5 eV near the collector plate to reduce sputtering. A power flow model has shown that the required power for heating the halo is low enough to make the halo recycler a practical concept

  12. Chemical modification of DNA: Molecular specificity studied by tandem mass spectrometry and liquid chromatography

    International Nuclear Information System (INIS)

    Chang, Ching-jer; Cooks, R.G.; Chae, Whi-Gun; Wood, J.M.

    1989-01-01

    Chemical modifications of DNA in vitro could be directly studied by C-13 NMR and P-31 NMR, which eliminated all degradation and separation processes. The prospects of utilized the NMR method in the in vitro experiments are limited because of the inherent low sensitivity of NMR and low level of DNA modification. We have developed a reverse-phase ion-paired HPLC method to study DNA modifications by methylating agents. The structural specificity of HPLC is significantly enhanced by conjunction with the specificity of enzymic transformations. The HPLC studies have also revealed the limitation of HPLC method for simultaneous determination of many minor modified nucleosides. This problem has been overcome by tandem mass spectrometry. In conjunction with the resolving power of HPLC in separating isomers, desorption chemical ionization tandem mass spectrometry has been utilized in the determination of the modified nucleosides at the picomole level using stable-isotope labeled compounds as internal references

  13. Tandem ion mobility spectrometry coupled to laser excitation

    Energy Technology Data Exchange (ETDEWEB)

    Simon, Anne-Laure; Choi, Chang Min; Clavier, Christian; Barbaire, Marc; Maurelli, Jacques; Dagany, Xavier; MacAleese, Luke; Dugourd, Philippe, E-mail: philippe.dugourd@univ-lyon1.fr [Institut Lumière Matière, Université de Lyon, Université Lyon 1-CNRS, 69622 Villeurbanne cedex (France); Chirot, Fabien [Institut des Sciences Analytiques, Université de Lyon, Université Lyon 1-CNRS, 69622 Villeurbanne cedex (France)

    2015-09-15

    This manuscript describes a new experimental setup that allows to perform tandem ion mobility spectrometry (IMS) measurements and which is coupled to a high resolution time-of-flight mass spectrometer. It consists of two 79 cm long drift tubes connected by a dual ion funnel assembly. The setup was built to permit laser irradiation of the ions in the transfer region between the two drift tubes. This geometry allows selecting ions according to their ion mobility in the first drift tube, to irradiate selected ions, and examine the ion mobility of the product ions in the second drift tube. Activation by collision is possible in the same region (between the two tubes) and between the second tube and the time-of-flight. IMS-IMS experiments on Ubiquitin are reported. We selected a given isomer of charge state +7 and explored its structural rearrangement following collisional activation between the two drift tubes. An example of IMS-laser-IMS experiment is reported on eosin Y, where laser irradiation was used to produce radical ions by electron photodetachment starting from doubly deprotonated species. This allowed measuring the collision cross section of the radical photo-product, which cannot be directly produced with an electrospray source.

  14. Prospects for a DD tandem mirror

    International Nuclear Information System (INIS)

    Logan, B.G.

    1977-01-01

    The possibility of burning advanced fusion fuels in a tandem mirror is considered for a catalyzed DD cycle, in which the T and 3 He reaction products from DD burn in both the solenoid and plugs are reinjected for complete burnup: 3D → p + 4 He + n + 21.6 MeV. Classical radial transport of the 4 He ash determines the steady state alpha fraction in the solenoid. Synchrotron radiation losses are minimized at high beta, such that charged particle fusion power recovered in a direct converter exceeds radiation losses by a factor greater than two. An overall system Q = 4.5 is found for one reaction example but the power output is large (3 GE(e) net) due to the low power density in the solenoid. Optimizing recirculating power cost (Q) against plug/solenoid density ratio (power density) should result in much smaller reactor size and cost

  15. Tandem mirror reactor power balance studies

    International Nuclear Information System (INIS)

    Gorker, G.E.; Perkins, L.J.

    1985-01-01

    A tandem mirror reactor (TMR) power plant balance model has been developed and is now being used as a computer aid for performing parametric studies. End-cell power injection into the plasma and the physics thermal Q are used to determine the fusion power. About 80% of the fusion power is transferred by high-energy neutrons to the blanket modules and structures. The other 20% of the fusion power in the high-energy alpha particles is used to heat the deuterium-tritium (D-T) plasma. Most of the plasma-ionized particles transfer their energy to the halo dumps and direct converters. The plant efficiency is calculated for three different system cycles: (1) the pressurized water/saturated steam cycle; (2) the superheated steam cycle; and (3) the more complex superheat/reheat cycle. There is a signficiant improvement in plant efficiency as the electrical power multiplication factor and steam cycle efficiency increases

  16. Stable operation of an effectively axisymmetric neutral beam driven tandem mirror

    International Nuclear Information System (INIS)

    Molvik, A.W.; Barter, J.D.; Buchenauer, D.A.; Casper, T.A.; Correll, D.L.; Dimonte, G.; Falabella, S.; Foote, J.H.; Pincosy, P.A.

    1990-01-01

    A quiescent plasma is sustained for 80 energy confinement times by only gas fuelling and neutral beam heating in an axisymmetric region of the Tandem Mirror Experiment Upgrade (TMX-U). This plasma should be unstable because of the bad magnetic curvature and the absence of ion cyclotron heating which previously provided ponderomotive stabilization to sustain plasmas in bad-curvature regions of other axisymmetric mirror experiments. The TMX-U data are consistent with stabilization by a symbiosis between two mechanisms - line tying, which reduces the growth rate, and finite Larmor radius edge stabilization, which can result in quiescent operation. (author). 42 refs, 8 figs, 1 tab

  17. Tandem repeat regions within the Burkholderia pseudomallei genome and their application for high resolution genotyping

    Directory of Open Access Journals (Sweden)

    Harvey Steven P

    2007-03-01

    Full Text Available Abstract Background The facultative, intracellular bacterium Burkholderia pseudomallei is the causative agent of melioidosis, a serious infectious disease of humans and animals. We identified and categorized tandem repeat arrays and their distribution throughout the genome of B. pseudomallei strain K96243 in order to develop a genetic typing method for B. pseudomallei. We then screened 104 of the potentially polymorphic loci across a diverse panel of 31 isolates including B. pseudomallei, B. mallei and B. thailandensis in order to identify loci with varying degrees of polymorphism. A subset of these tandem repeat arrays were subsequently developed into a multiple-locus VNTR analysis to examine 66 B. pseudomallei and 21 B. mallei isolates from around the world, as well as 95 lineages from a serial transfer experiment encompassing ~18,000 generations. Results B. pseudomallei contains a preponderance of tandem repeat loci throughout its genome, many of which are duplicated elsewhere in the genome. The majority of these loci are composed of repeat motif lengths of 6 to 9 bp with 4 to 10 repeat units and are predominately located in intergenic regions of the genome. Across geographically diverse B. pseudomallei and B.mallei isolates, the 32 VNTR loci displayed between 7 and 28 alleles, with Nei's diversity values ranging from 0.47 and 0.94. Mutation rates for these loci are comparable (>10-5 per locus per generation to that of the most diverse tandemly repeated regions found in other less diverse bacteria. Conclusion The frequency, location and duplicate nature of tandemly repeated regions within the B. pseudomallei genome indicate that these tandem repeat regions may play a role in generating and maintaining adaptive genomic variation. Multiple-locus VNTR analysis revealed extensive diversity within the global isolate set containing B. pseudomallei and B. mallei, and it detected genotypic differences within clonal lineages of both species that were

  18. DB2: a probabilistic approach for accurate detection of tandem duplication breakpoints using paired-end reads.

    Science.gov (United States)

    Yavaş, Gökhan; Koyutürk, Mehmet; Gould, Meetha P; McMahon, Sarah; LaFramboise, Thomas

    2014-03-05

    With the advent of paired-end high throughput sequencing, it is now possible to identify various types of structural variation on a genome-wide scale. Although many methods have been proposed for structural variation detection, most do not provide precise boundaries for identified variants. In this paper, we propose a new method, Distribution Based detection of Duplication Boundaries (DB2), for accurate detection of tandem duplication breakpoints, an important class of structural variation, with high precision and recall. Our computational experiments on simulated data show that DB2 outperforms state-of-the-art methods in terms of finding breakpoints of tandem duplications, with a higher positive predictive value (precision) in calling the duplications' presence. In particular, DB2's prediction of tandem duplications is correct 99% of the time even for very noisy data, while narrowing down the space of possible breakpoints within a margin of 15 to 20 bps on the average. Most of the existing methods provide boundaries in ranges that extend to hundreds of bases with lower precision values. Our method is also highly robust to varying properties of the sequencing library and to the sizes of the tandem duplications, as shown by its stable precision, recall and mean boundary mismatch performance. We demonstrate our method's efficacy using both simulated paired-end reads, and those generated from a melanoma sample and two ovarian cancer samples. Newly discovered tandem duplications are validated using PCR and Sanger sequencing. Our method, DB2, uses discordantly aligned reads, taking into account the distribution of fragment length to predict tandem duplications along with their breakpoints on a donor genome. The proposed method fine tunes the breakpoint calls by applying a novel probabilistic framework that incorporates the empirical fragment length distribution to score each feasible breakpoint. DB2 is implemented in Java programming language and is freely available

  19. In-terminal ECR Ion Source of the Tandem Accelerator at JAERI

    CERN Document Server

    Matsuda, M; Takeuchi, S

    1999-01-01

    Electron Cyclotron Resonance Ion Source(ECRIS)s are able to produce intense beams of highly charged positive ions and used injection system for cyclotron, linac as well as experiments of atomic physics. The tandem accelerator system has been benefiting from use of an electron stripper at the high voltage terminal. The most probable charged state after a foil stripper is, however, much lower than the highest charge state of ions with an intensity of more than several emA from a high performance ECRIS. With respect to beam current, the life time of stripper foils decrease with increasing beam current. Especially for very heavy ions, it is difficult to obtain a stable and intense beam for a long time without foil exchange. Use of an ECRIS in a tandem accelerator is expected to increase beam intensity, beam energy and beam species. A small permanent magnet ECRIS has been installed in the high voltage terminal of the vertical and folded type 20UR Pelletron tandem accelerator at Japan Atomic Energy Research Institu...

  20. Des hôtesses de karaoké à Phnom Penh Karaoke Hostesses in Phnom Penh. Negotiating Risk in Reproductive Health

    Directory of Open Access Journals (Sweden)

    Pascale Hancart-Petitet

    2012-10-01

    Full Text Available Au Cambodge, dans un contexte alliant paupérisation et forte pression sociale à la consommation, des jeunes femmes issues de milieux ruraux viennent s’installer à Phnom Penh, la capitale, afin de trouver une activité permettant de subvenir à leurs besoins et à ceux de leur famille. Parmi elles, nombreuses sont celles qui, par l’intermédiaire d’un membre de leur réseau familial ou amical, ou à la suite d’une information glanée à l’occasion d’une rencontre sur place, trouvent une activité en tant qu’hôtesse de bar karaoké. Cette activité induit des changements corporels, sociaux et culturels divers pour ces jeunes femmes et modifie en partie leur rapport à leur féminité, à leur sexualité et à leur santé. Considérées par les acteurs de santé publique comme des « populations vulnérables », en particulier en raison de leur activité dans la vente de services sexuels, ces femmes sont, parfois, la cible d’activités de prévention et de soins en santé de la reproduction. Cette contribution approche, d’une part, certains aspects de la construction des politiques sanitaires dans le contexte de la prostitution au Cambodge. Par ailleurs, l’article vise à explorer la façon dont ces jeunes femmes s’accommodent de leur nouveau rôle et dont elles mettent en œuvre, négocient ou détournent les pratiques de soins recommandées en matière de prévention du VIH et des grossesses non désirées. Les données ethnographiques illustrent comment les migrations spatiales et sociales des femmes observées au Cambodge induisent des pratiques « inédites » en santé de la reproduction ainsi que des formes nouvelles de construction d’identité de genre et du corps féminin. Au-delà, cette contribution propose de revisiter le conceptIn Cambodia, young women from rural areas come to live in Phnom Penh, the capital city, in order to find an activity able to meet their needs and those of their families. Among

  1. Vacuum vessel for the tandem Mirror Fusion Test Facility

    International Nuclear Information System (INIS)

    Gerich, J.W.

    1986-01-01

    In 1980, the US Department of Energy gave the Lawrence Livermore National Laboratory approval to design and build a tandem Mirror Fusion Test Facility (MFTF-B) to support the goals of the National Mirror Program. We designed the MFTF-B vacuum vessel both to maintain the required ultrahigh vacuum environment and to structurally support the 42 superconducting magnets plus auxiliary internal and external equipment. During our design work, we made extensive use of both simple and complex computer models to arrive at a cost-effective final configuration. As part of this work, we conducted a unique dynamic analysis to study the interaction of the 32,000-tonne concrete-shielding vault with the 2850-tonne vacuum vessel system. To maintain a vacuum of 2 x 10 -8 torr during the physics experiments inside the vessel, we designed a vacuum pumping system of enormous capacity. The vacuum vessel (4200-m 3 internal volume) has been fabricated and erected, and acceptance tests have been completed at the Livermore site. The rest of the machine has been assembled, and individual systems have been successfully checked. On October 1, 1985, we began a series of integrated engineering tests to verify the operation of all components as a complete system

  2. Role of ECRH in potential formation for tandem mirrors

    International Nuclear Information System (INIS)

    Rognlien, T.D.; Matsuda, Y.; Stewart, J.J.

    1985-01-01

    The axial ion plugging potential in a tandem mirror is produced by electron cyclotron resonance heating (ECRH) applied at two locations in the end mirror cell. A second harmonic (ω = 2ω/sub c/) resonance is used near the midplane to generate hot electrons which yield an electron potential barrier between center cell electrons and electrons outboard of the end cell midplane. The latter group of electrons is then heated at the fundamental resonance (ω = ω/sub c/) on the outboard side of the magnetic well which drives an ion confining potential. Fokker-Planck and Monte Carlo calculations show that such a configuration is achievable, and the scaling obeys a rather simple set of equations. Another aspect of this configuration is the experimental observation that the fundamental heating drives the overall potential of the device relative to the wall to approx. 1 kV. An analytic model predicts this behavior for very strong ECRH. Results are given a numerical study of electron confinement in a mirror cell owing to fundamental heating as the level of the rf electric field, E/sub rf/, is increased. For the second part of the paper, we show that moderate levels of uniformly distributed rf fields, called cavity fields, can result in very hot (>250 keV) tails in the electron distribution as seen in the TMX-U experiment

  3. Concurrent control system for the JAERI tandem accelerator

    International Nuclear Information System (INIS)

    Hanashima, Susumu; Shozi, Tokio; Shiozaki, Yasuo; Saito, Motoi; Oogane, Yasuo; Sekiguchi, Satoshi.

    1994-01-01

    A new control system for the JAERI tandem accelerator is constructed. The system utilizes concurrent processing technology with multiprocessor. Transputers are used both for central processor and I/O front end processors. (author)

  4. Monolithic Perovskite Silicon Tandem Solar Cells with Advanced Optics

    Energy Technology Data Exchange (ETDEWEB)

    Goldschmidt, Jan C.; Bett, Alexander J.; Bivour, Martin; Blasi, Benedikt; Eisenlohr, Johannes; Kohlstadt, Markus; Lee, Seunghun; Mastroianni, Simone; Mundt, Laura; Mundus, Markus; Ndione, Paul; Reichel, Christian; Schubert, Martin; Schulze, Patricia S.; Tucher, Nico; Veit, Clemens; Veurman, Welmoed; Wienands, Karl; Winkler, Kristina; Wurfel, Uli; Glunz, Stefan W.; Hermle, Martin

    2016-11-14

    For high efficiency monolithic perovskite silicon tandem solar cells, we develop low-temperature processes for the perovskite top cell, rear-side light trapping, optimized perovskite growth, transparent contacts and adapted characterization methods.

  5. Argonne tandem as injector to a superconducting linac

    International Nuclear Information System (INIS)

    Yntema, J.L.; Den Hartog, P.K.; Henning, W.; Kutschera, W.

    1980-01-01

    The Argonne Tandem uses Pelletron chains, NEC accelerator tubes, and a dual closed-corona system. Its main function is to be an injector for a superconducting linear accelerator. As long as the transverse and longitudinal emittances are within the acceptance of the linac, the output beam quality of the tandem-linac system is essentially determined by the tandem. The sensitivity of the linac to the longitudinal emittance ΔEΔt of the incident beam makes the output beam quality dependent on the negative-ion velocity distribution in the source, transit-time effects in the tandem, molecular-beam dissociation, and stripper-foil uniformity. This paper discusses these beam-degrading effects

  6. Green oxidations: Titanium dioxide induced tandem oxidation coupling reactions

    OpenAIRE

    Jeena, Vineet; Robinson, Ross S

    2009-01-01

    Summary The application of titanium dioxide as an oxidant in tandem oxidation type processes is described. Under microwave irradiation, quinoxalines have been synthesized in good yields from the corresponding ?-hydroxyketones.

  7. Tandem Wittig-ene reaction approach to kainic acid

    Digital Repository Service at National Institute of Oceanography (India)

    Majik, M.S.; Parameswaran, P.S.; Tilve, S.G.

    The first example of a tandem Wittig-intramolecular ene reaction approach and its application toward the synthesis of kainic acid is reported. The synthetic pathway involves conversion of prenyl bromide into phosphorane 3, followed by one-pot Wittig...

  8. Solution-Processed Nanocrystal Quantum Dot Tandem Solar Cells

    KAUST Repository

    Choi, Joshua J.; Wenger, Whitney N.; Hoffman, Rachel S.; Lim, Yee-Fun; Luria, Justin; Jasieniak, Jacek; Marohn, John A.; Hanrath, Tobias

    2011-01-01

    Solution-processed tandem solar cells created from nanocrystal quantum dots with size-tuned energy levels are demonstrated. Prototype devices featuring interconnected quantum dot layers of cascaded energy gaps exhibit IR sensitivity and an open circuit voltage, V oc, approaching 1 V. The tandem solar cell performance depends critically on the optical and electrical properties of the interlayer. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Zinc Mediated Tandem Fragmentation-Allylation of Methyl 5-Iodopentofuranosides

    DEFF Research Database (Denmark)

    Hyldtoft, Lene; Madsen, Robert

    1999-01-01

    In the presence of zinc and allyl bromide methyl 5-iodopentofuranosides undergo a tandem fragmentation alkylation to give functionalized dienes. These can undergo ring-closing olefin metathesis to produce cyclohexenes which on dihydroxylation give quercitols.......In the presence of zinc and allyl bromide methyl 5-iodopentofuranosides undergo a tandem fragmentation alkylation to give functionalized dienes. These can undergo ring-closing olefin metathesis to produce cyclohexenes which on dihydroxylation give quercitols....

  10. Solution-Processed Nanocrystal Quantum Dot Tandem Solar Cells

    KAUST Repository

    Choi, Joshua J.

    2011-06-03

    Solution-processed tandem solar cells created from nanocrystal quantum dots with size-tuned energy levels are demonstrated. Prototype devices featuring interconnected quantum dot layers of cascaded energy gaps exhibit IR sensitivity and an open circuit voltage, V oc, approaching 1 V. The tandem solar cell performance depends critically on the optical and electrical properties of the interlayer. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. The pressure vessel for the NSF tandem

    International Nuclear Information System (INIS)

    Jones, C.W.

    1979-04-01

    The pressure vessel is a major component of the 30 MV tandem Van de Graaff electrostatic accelerator to be used in nuclear structure research at Daresbury Laboratory. The accelerator will be capable of accelerating the full range of ions in the form of a beam. Acceleration takes place in a vertical evacuated tube (beam tube) by means of a high potential on a terminal at the central position, the terminal and beam tube assembly being supported by an insulated stack structure within the pressure vessel. Under operating conditions the vessel is filled with sulphur hexafluoride gas (SF 6 ) at high pressure which acts as an insulating medium between the centre terminal and the vessel wall. The vessel is situated inside a concrete tower which besides supporting the injector room above the vessel also acts as radiation shielding around the accelerator. The report covers: functional requirements; fundamental considerations with regard to the design and procurement; detail design; materials; manufacture; acceptance test; surface treatment; final leak test. (U.K.)

  12. Short tandem repeat analysis in Japanese population.

    Science.gov (United States)

    Hashiyada, M

    2000-01-01

    Short tandem repeats (STRs), known as microsatellites, are one of the most informative genetic markers for characterizing biological materials. Because of the relatively small size of STR alleles (generally 100-350 nucleotides), amplification by polymerase chain reaction (PCR) is relatively easy, affording a high sensitivity of detection. In addition, STR loci can be amplified simultaneously in a multiplex PCR. Thus, substantial information can be obtained in a single analysis with the benefits of using less template DNA, reducing labor, and reducing the contamination. We investigated 14 STR loci in a Japanese population living in Sendai by three multiplex PCR kits, GenePrint PowerPlex 1.1 and 2.2. Fluorescent STR System (Promega, Madison, WI, USA) and AmpF/STR Profiler (Perkin-Elmer, Norwalk, CT, USA). Genomic DNA was extracted using sodium dodecyl sulfate (SDS) proteinase K or Chelex 100 treatment followed by the phenol/chloroform extraction. PCR was performed according to the manufacturer's protocols. Electrophoresis was carried out on an ABI 377 sequencer and the alleles were determined by GeneScan 2.0.2 software (Perkin-Elmer). In 14 STRs loci, statistical parameters indicated a relatively high rate, and no significant deviation from Hardy-Weinberg equilibrium was detected. We apply this STR system to paternity testing and forensic casework, e.g., personal identification in rape cases. This system is an effective tool in the forensic sciences to obtain information on individual identification.

  13. Engineering problems of tandem-mirror reactors

    International Nuclear Information System (INIS)

    Moir, R.W.; Barr, W.L.; Boghosian, B.M.

    1981-01-01

    We have completed a comparative evaluation of several end plug configurations for tandem mirror fusion reactors with thermal barriers. The axi-cell configuration has been selected for further study and will be the basis for a detailed conceptual design study to be carried out over the next two years. The axi-cell end plug has a simple mirror cell produced by two circular coils followed by a transition coil and a yin-yang pair, which provides for MHD stability. This paper discusses some of the many engineering problems facing the designer. We estimated the direct cost to be 2$/W/sub e/. Assuming total (direct and indirect) costs to be twice this number, we need to reduce total costs by factors between 1.7 and 2.3 to compete with future LWRs levelized cost of electricity. These reductions may be possible by designing magnets producing over 20T made possible by use of combinations of superconducting and normal conducting coils as well as improvements in performance and cost of neutral beam and microwave power systems. Scientific and technological understanding and innovation are needed in the area of thermal barrier pumping - a process by which unwanted particles are removed (pumped) from certain regions of velocity and real space in the end plug. Removal of exhaust fuel ions, fusion ash and impurities by action of a halo plasma and plasma dump in the mirror end region is another challenging engineering problem discussed in this paper

  14. Transcription of tandemly repetitive DNA: functional roles.

    Science.gov (United States)

    Biscotti, Maria Assunta; Canapa, Adriana; Forconi, Mariko; Olmo, Ettore; Barucca, Marco

    2015-09-01

    A considerable fraction of the eukaryotic genome is made up of satellite DNA constituted of tandemly repeated sequences. These elements are mainly located at centromeres, pericentromeres, and telomeres and are major components of constitutive heterochromatin. Although originally satellite DNA was thought silent and inert, an increasing number of studies are providing evidence on its transcriptional activity supporting, on the contrary, an unexpected dynamicity. This review summarizes the multiple structural roles of satellite noncoding RNAs at chromosome level. Indeed, satellite noncoding RNAs play a role in the establishment of a heterochromatic state at centromere and telomere. These highly condensed structures are indispensable to preserve chromosome integrity and genome stability, preventing recombination events, and ensuring the correct chromosome pairing and segregation. Moreover, these RNA molecules seem to be involved also in maintaining centromere identity and in elongation, capping, and replication of telomere. Finally, the abnormal variation of centromeric and pericentromeric DNA transcription across major eukaryotic lineages in stress condition and disease has evidenced the critical role that these transcripts may play and the potentially dire consequences for the organism.

  15. Analysis of tandem mirror reactor performance

    International Nuclear Information System (INIS)

    Wu, K.F.; Campbell, R.B.; Peng, Y.K.M.

    1984-11-01

    Parametric studies are performed using a tandem mirror plasma point model to evaluate the wall loading GAMMA and the physics figure of merit, Q (fusion power/injected power). We explore the relationship among several dominant parameters and determine the impact on the plasma performance of electron cyclotron resonance heating in the plug region. These global particle and energy balance studies were carried out under the constraints of magnetohydrodynamic (MHD) equilibrium and stability and constant magnetic flux, assuming a fixed end-cell geometry. We found that the higher the choke coil fields, the higher the Q, wall loading, and fusion power due to the combination of the increased central-cell field B/sub c/ and density n/sub c/ and the reduced central-cell beta β/sub c/. The MHD stability requirement of constant B/sub c/ 2 β/sub c/ causes the reduction in β/sub c/. In addition, a higher value of fusion power can also be obtained, at a fixed central-cell length, by operating at a lower value of B/sub c/ and a higher value of β/sub c/

  16. Tandem mass spectrometry: analysis of complex mixtures

    International Nuclear Information System (INIS)

    Singleton, K.E.

    1985-01-01

    Applications of tandem mass spectrometry (MS/MS) for the analysis of complex mixtures results in increased specificity and selectivity by using a variety of reagent gases in both negative and positive ion modes. Natural isotopic abundance ratios were examined in both simple and complex mixtures using parent, daughter and neutral loss scans. MS/MS was also used to discover new compounds. Daughter scans were used to identify seven new alkaloids in a cactus species. Three of these alkaloids were novel compounds, and included the first simple, fully aromatic isoquinoline alkaloids reported in Cactaceae. MS/MS was used to characterize the chemical reaction products of coal in studies designed to probe its macromolecular structure. Negative ion chemical ionization was utilized to study reaction products resulting from the oxidation of coal. Possible structural units in the precursor coal were predicted based on the reaction products identified, aliphatic and aromatic acids and their anhydrides. The MS/MS method was also used to characterize reaction products resulting from coal liquefaction and/or extraction. These studies illustrate the types of problems for which MS/MS is useful. Emphasis has been placed on characterization of complex mixtures by selecting experimental parameters which enhance the information obtained. The value of using MS/MS in conjunction with other analytical techniques as well as the chemical pretreatment is demonstrated

  17. Software dependability in the Tandem GUARDIAN system

    Science.gov (United States)

    Lee, Inhwan; Iyer, Ravishankar K.

    1995-01-01

    Based on extensive field failure data for Tandem's GUARDIAN operating system this paper discusses evaluation of the dependability of operational software. Software faults considered are major defects that result in processor failures and invoke backup processes to take over. The paper categorizes the underlying causes of software failures and evaluates the effectiveness of the process pair technique in tolerating software faults. A model to describe the impact of software faults on the reliability of an overall system is proposed. The model is used to evaluate the significance of key factors that determine software dependability and to identify areas for improvement. An analysis of the data shows that about 77% of processor failures that are initially considered due to software are confirmed as software problems. The analysis shows that the use of process pairs to provide checkpointing and restart (originally intended for tolerating hardware faults) allows the system to tolerate about 75% of reported software faults that result in processor failures. The loose coupling between processors, which results in the backup execution (the processor state and the sequence of events) being different from the original execution, is a major reason for the measured software fault tolerance. Over two-thirds (72%) of measured software failures are recurrences of previously reported faults. Modeling, based on the data, shows that, in addition to reducing the number of software faults, software dependability can be enhanced by reducing the recurrence rate.

  18. WE-A-17A-05: Differences in Applicator Configuration and Dwell Loading Between Standard and Image-Guided Tandem and Ring (T and R) HDR Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Damato, A; Cormack, R; Bhagwat, M; Buzurovic, I; Lee, L; Viswanathan, A [Brigham and Women' s Hospital, Boston, MA (United States)

    2014-06-15

    Purpose: To investigate differences in: (i) relative location of the tandem and the ring compared to a rigid standard applicator model; and (ii) relative loading and changes in loading pattern between standard and image-guided planning. Methods: All T and R insertions performed in 2013 in our institution under CT- or MR-guidance were analyzed. Standard plans were generated using library applicator models with a fixed relationship between ring and tandem, standardized uniform dwell loading and normalization to point A. The graphic plans and the associated standard-plan dwell configurations were compared: the rings were rigidly registered, and the residual tandem shift, rotation and maximum distance between plan tandem dwell and corresponding model tandem dwell were calculated. The normalization ratio (NR = the ratio of graphic versus standard-plan total reference air kerma [TRAK]), the general loading difference (GLD = the difference between graphic and standard ratios of the tandem versus the ring TRAK), and the percent standard deviation (SD% = SD/mean) of the tandem and the ring TRAK for the graphic plan (all standard-plans SD% = 0) were calculated. Results: 71 T and R were analyzed. Residual tandem shift, rotation and maximum corresponding dwell distance were 1.2±0.8mm (0.4±0.4mm lateral, 0.9±0.8mm craniocaudal, 0.4±0.3mm anterior-posterior), 2.3±1.9deg and 3.4±2.3mm. NR was 0.86±0.11 indicating a lower overall loading of the graphic compared to the standard plans. GLD was -0.12±0.16 indicating a modest increased ring loading relative to the tandem in the graphic plans. SD% was 2.1±1.6% for tandem and 2.8±1.9% for ring, indicating small deviations from uniform loading. Conclusion: Variability in the relative locations of the tandem and the ring necessitates the independent registration of each component model for accurate digitization. Our clinical experience suggests that graphically planned T and R results on average in a lower total dose to the

  19. WE-A-17A-05: Differences in Applicator Configuration and Dwell Loading Between Standard and Image-Guided Tandem and Ring (T and R) HDR Brachytherapy

    International Nuclear Information System (INIS)

    Damato, A; Cormack, R; Bhagwat, M; Buzurovic, I; Lee, L; Viswanathan, A

    2014-01-01

    Purpose: To investigate differences in: (i) relative location of the tandem and the ring compared to a rigid standard applicator model; and (ii) relative loading and changes in loading pattern between standard and image-guided planning. Methods: All T and R insertions performed in 2013 in our institution under CT- or MR-guidance were analyzed. Standard plans were generated using library applicator models with a fixed relationship between ring and tandem, standardized uniform dwell loading and normalization to point A. The graphic plans and the associated standard-plan dwell configurations were compared: the rings were rigidly registered, and the residual tandem shift, rotation and maximum distance between plan tandem dwell and corresponding model tandem dwell were calculated. The normalization ratio (NR = the ratio of graphic versus standard-plan total reference air kerma [TRAK]), the general loading difference (GLD = the difference between graphic and standard ratios of the tandem versus the ring TRAK), and the percent standard deviation (SD% = SD/mean) of the tandem and the ring TRAK for the graphic plan (all standard-plans SD% = 0) were calculated. Results: 71 T and R were analyzed. Residual tandem shift, rotation and maximum corresponding dwell distance were 1.2±0.8mm (0.4±0.4mm lateral, 0.9±0.8mm craniocaudal, 0.4±0.3mm anterior-posterior), 2.3±1.9deg and 3.4±2.3mm. NR was 0.86±0.11 indicating a lower overall loading of the graphic compared to the standard plans. GLD was -0.12±0.16 indicating a modest increased ring loading relative to the tandem in the graphic plans. SD% was 2.1±1.6% for tandem and 2.8±1.9% for ring, indicating small deviations from uniform loading. Conclusion: Variability in the relative locations of the tandem and the ring necessitates the independent registration of each component model for accurate digitization. Our clinical experience suggests that graphically planned T and R results on average in a lower total dose to the

  20. Actualization of the Tandem-E N Accelerator of the Nuclear Centre of Mexico; Actualizacion del Acelerador Tandem-EN del Centro Nuclear

    Energy Technology Data Exchange (ETDEWEB)

    Villasenor S, P.; Aguilera R, E.; Aspiazu F, J.; Fernandez A, J.; Fernandez B, M.; Garcia R, B.; Lopez M, J.; Martinez Q, E.; Mendez G, B.; Moreno B, E.; Murillo O, G.; Policroniades R, R.; Ramirez T, J.; Reynoso V, R.; Varela G, A.; Vega C, J. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)

    2004-07-01

    In this work, the activities are described carried out to change the tubes accelerators and original resistances of the accelerator Tandem-E N of the Nuclear Center, for tubes DOWLISH and resistances again design, both donated ones for ORNL. This way same, the problem is described that imply this changes, and like it was solved by the personnel of the laboratory, without having to appeal to external services, what there is redounded in a considerable increment in the costs. In form preliminary the improvements are described observed after the rehabilitation of the Accelerator. (Author)

  1. Annual report of the Tandem Accelerator Center, University of Tsukuba. April 1, 1993 - March 31, 1994

    International Nuclear Information System (INIS)

    1994-07-01

    In this annual report, the research activities and the technical developments carried out at the Tandem Accelerator Center, University of Tsukuba, for the period from April, 1993 to March, 1994 are described. The tandem accelerator worked with high stability, and provided with sufficient beam time for experiments till the middle of November, however, one of the charging chains broke on November 18. The replacement of the chain was finished in a short time, and experiments were continued to the end of December. From January, 1994, the operation of the accelerator was shut down to replace the cooling towers for building air conditioning and to reconstruct the cooling system for the accelerator. In this book, the activities in the accelerator and experimental facilities and the departments of the experiment and theory on nuclear physics, atomic and solid state physics, and ion beam application are reported. As the new development of experimental instruments, a new rf amplifier for the heavy ion postaccelerator was constructed, and with a liquid helium polarimeter, test experiments are in progress. (K.I.)

  2. Annual report of Department of Research Reactors and Tandem Accelerator, JFY2006. Operation, utilization and technical development of JRR-3, JRR-4, NSRR and Tandem Accelerator

    International Nuclear Information System (INIS)

    2007-12-01

    The Department of Research Reactors and Tandem Accelerator is in charge of the operation, utilization and technical development of JRR-3 (Japan Research Reactor-3), JRR-4 (Japan Research Reactor-4) and NSRR (Nuclear Safety Research Reactor) and Tandem Accelerator. The following services and technical developments were achieved in Japanese Fiscal Year 2006: 1) JRR-3 was operated for 181 days in 7 cycles and JRR-4 for 149 days in 37 cycles to provide neutrons for research and development of in-house and outside users. 2) JRR-3 and JRR-4 were utilized through deliberate coordination as follows, a) Neutron irradiations of 628 materials, for neutron transmutation doping of silicon etc. b) Capsule irradiations of 3,067 samples, for neutron activation analyses etc. c) Neutron beam experiments of 6,338 cases x days. 3) Concerning to the 10 times increasing plan of cold neutron beams from JRR-3, a pressure resistant test model of the high-performance neutron moderator vessel which had been designed to increase cold neutrons twice as much as the present one was fabricated. Various developments for upgrading cold neutron guide tubes with super mirrors were in progress. 4) Boron neutron capture therapy was carried out 34 times using JRR-4. Improved neutron collimators were built to fit well to any irregular outline for cancer around the neck. 5) NSRR carried out 4 times of pulse irradiations of high burn-up MOX fuels and 9 times of un-irradiated fuels to contribute to fuel safety researches. 6) The Tandem Accelerator was operated for 201 days to contribute to the researches of nuclear physics and solid state physics with high energy heavy ions. The new utilization program of sharing beam times with outside users was performed by carrying out 45 days. The beam intensity increasing program with a high performance ion source, in place of the compact one which has been working in the high voltage terminal, has made great progress. (author)

  3. High performance and thermally stable tandem solar selective absorber coating for concentrated solar thermal power (CSP) application

    Science.gov (United States)

    Prasad, M. Shiva; Kumar, K. K. Phani; Atchuta, S. R.; Sobha, B.; Sakthivel, S.

    2018-05-01

    A novel tandem absorber system (Mn-Cu-Co-Ox-ZrO2/SiO2) developed on an austenitic stainless steel (SS-304) substrate to show an excellent optical performance (αsol: 0.96; ɛ: 0.23@500 °C). In order to achieve this durable tandem, we experimented with two antireflective layers such as ZrO2-SiO2 and nano SiO2 layer on top of Mn-Cu-Co-Ox-ZrO2 layer. We optimized the thickness of antireflective layers to get good tandem system in terms of solar absorptance and emittance. Field emission scanning electron microscopy (FESEM), UV-Vis-NIR and Fourier transform infrared spectroscopy (FTIR) were used to characterize the developed coatings. Finally, the Mn-Cu-Co-Ox-ZrO2/SiO2 exhibits high temperature resistance up to 800 °C, thus allow an increase in the operating temperature of CSP which may lead to high efficiency. We successfully developed a high temperature resistant tandem layer with easy manufacturability at low cost which is an attractive candidate for concentrated solar power generation (CSP).

  4. Use of a tandem accelerator in the basic studies on nuclear fusion and environmental diagnostics

    International Nuclear Information System (INIS)

    Oguri, Yoshiyuki; Hasegawa, Jun; Fukuda, Hitoshi; Ogawa, Masao

    2001-01-01

    A small tandem electrostatic accelerator has worked well 16 years after installation. In the last year, however, a pellet chain touched to inductor and a considerable amount of metallic powder was sprayed inside the pressure vessel. Basic experiments have been made on the interaction of plasma and heavy ion beams. Stopping powers of a plasma produced by laser irradiation were measured as a function of the injection energy. In addition, fabrication of solid hydrogen targets has been tried. PIXE analysis has been applied to air pollution in monitoring a long major roads. In addition preparatory treatments and procedures for thick samples are tested. (M. Tanaka)

  5. Giessen polarization facility. II. 1. 2 MeV tandem accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Arnold, W; Ulbricht, J; Berg, H; Keiner, P; Krause, H H; Schmidt, R; Clausnitzer, G [Giessen Univ. (Germany, F.R.). Strahlenzentrum

    1977-06-15

    A small pressure insulated tandem accelerator with 600 kV terminal voltage was constructed for the application of a polarized ion source of the Lambshift type: thin carbon foils or gas stripping is used for the charge exchange in the high voltage terminal. The calculated ion optical properties were realized in the construction; transmission and energy resolution are sufficient to obtain high intensity polarized beams on target (maximum 0.6..mu..A protons with P=0.75 ) for precision polarization experiments in the 0.2-1.2 MeV energy region.

  6. Study of carbon ion behavior by using collisional radiative model in the GAMMA 10 tandem mirror

    International Nuclear Information System (INIS)

    Kobayashi, Takayuki; Yoshikawa, Masayuki; Kubota, Yuusuke; Saito, Masashi; Matama, Ken; Itakura, Akiyoshi; Cho, Teruji; Kato, Takako

    2006-01-01

    In a plasma experiment, collisional radiative model (CRM) is very useful model to evaluate impurity behaviors and plasma parameters with line emission from a plasma. CRMs for carbon and oxygen have been developed. However verification and application of the model for analysis of experimental results are not enough. Then we applied CRM calculation results to observed impurity spectra in the GAMMA 10 tandem mirror to evaluate the impurity density profile and the particle balance of each charge state of carbon ion. We calculated the effective ionization rate for each charge state of carbon ion and obtained the density profile of each ion. Moreover, we calculated absolute emission intensities from all carbon ions. (author)

  7. Test facility of proton beam utilization of the PEFP at the SNU-AMS tandem accelerator

    International Nuclear Information System (INIS)

    Kim, K. R.; Park, B. S.; Lee, H. R.

    2004-01-01

    The PEFP (Proton Engineering Frontier Project) will supply users with a 20-MeV proton beam by the middle of 2007. A survey on users' demand was performed to draw the concept for the 20-MeV user facilities and to investigate users' requirements. In the mean time, a 6-MeV test facility has been developed to give users opportunities to experiment with proton beams. That facility will be attached to the 3-MV tandem accelerator at Seoul National University.

  8. The impact of genome triplication on tandem gene evolution in Brassica rapa

    Directory of Open Access Journals (Sweden)

    Lu eFang

    2012-11-01

    Full Text Available Whole genome duplication (WGD and tandem duplication (TD are both important modes of gene expansion. However, how whole genome duplication influences tandemly duplicated genes is not well studied. We used Brassica rapa, which has undergone an additional genome triplication (WGT and shares a common ancestor with Arabidopsis thaliana, Arabidopsis lyrata and Thellungiella parvula, to investigate the impact of genome triplication on tandem gene evolution. We identified 2,137, 1,569, 1,751 and 1,135 tandem gene arrays in B. rapa, A. thaliana, A. lyrata and T. parvula respectively. Among them, 414 conserved tandem arrays are shared by the 3 species without WGT, which were also considered as existing in the diploid ancestor of B. rapa. Thus, after genome triplication, B. rapa should have 1,242 tandem arrays according to the 414 conserved tandems. Here, we found 400 out of the 414 tandems had at least one syntenic ortholog in the genome of B. rapa. Furthermore, 294 out of the 400 shared syntenic orthologs maintain tandem arrays (more than one gene for each syntenic hit in B. rapa. For the 294 tandem arrays, we obtained 426 copies of syntenic paralogous tandems in the triplicated genome of B. rapa. In this study, we demonstrated that tandem arrays in B. rapa were dramatically fractionated after WGT when compared either to non-tandem genes in the B. rapa genome or to the tandem arrays in closely related species that have not experienced a recent whole-genome polyploidization event.

  9. In situ ion irradiation/implantation studies in the HVEM-Tandem Facility at Argonne National Laboratory

    International Nuclear Information System (INIS)

    Allen, C.W.; Funk, L.L.; Ryan, E.A.; Taylor, A.

    1988-09-01

    The HVEM-Tandem User Facility at Argonne National Laboratory interfaces two ion accelerators, a 2 MV tandem accelerator and a 650 kV ion implanter, to a 1.2 MV high voltage electron microscope. This combination allows experiments involving simultaneous ion irradiation/ion implantation, electron irradiation and electron microscopy/electron diffraction to be performed. In addition the availability of a variety of microscope sample holders permits these as well as other types of in situ experiments to be performed at temperatures ranging from 10-1300 K, with the sample in a stressed state or with simultaneous determination of electrical resistivity of the specimen. This paper summarizes the details of the Facility which are relevant to simultaneous ion beam material modification and electron microscopy, presents several current applications and briefly describes the straightforward mechanism for potential users to access this US Department of Energy supported facility. 7 refs., 1 fig., 1 tab

  10. The design and numerical analysis of tandem thermophotovoltaic cells

    International Nuclear Information System (INIS)

    Yang Hao-Yu; Liu Ren-Jun; Wang Lian-Kai; Lü You; Li Tian-Tian; Li Guo-Xing; Zhang Yuan-Tao; Zhang Bao-Lin

    2013-01-01

    In this paper, numerical analysis of GaSb =(E g = 0.72 eV)/Ga 0.84 In 0.16 As 0.14 Sb 0.86 (E g = 0.53 eV) tandem thermophotovoltaic (TPV) cells is carried out by using Silvaco/Atlas software. In the tandem cells, a GaSb p-n homojunction is used for the top cell and a GaInAsSb p-n homojunction for the bottom cell. A heavily doped GaSb tunnel junction connects the two sub-cells together. The simulations are carried out at a radiator temperature of 2000 K and a cell temperature of 300 K. The radiation photons are injected from the top of the tandem cells. Key properties of the single- and dual-junction TPV cells, including I–V characteristic, maximum output power (P max ), open-circuit voltage (V oc ), short-circuit current (I sc ), etc. are presented. The effects of the sub-cell thickness and carrier concentration on the key properties of tandem cells are investigated. A comparison of the dual-TPV cells with GaSb and GaInAsSb single junction cells shows that the P max of tandem cells is almost twice as great as that of the single-junction cells. (interdisciplinary physics and related areas of science and technology)

  11. A high-resolution tandem mass spectrometer for the collision-induced dissociation of large molecule ions

    International Nuclear Information System (INIS)

    Ouwerkerk, C.E.D.

    1988-01-01

    Instrumental development in the field of tandem mass spectrometry is described in order to use the technique for the analysis of large organic molecules. Experiments are also described in which the process of collision-induced dissociation (CID) is investigated. The fragmentation pattern of CH 4 + has been measured for three different target gases He, Ar and Xe. From these measurements fragmentation cross sections are calculated. 192 refs.; 47 figs.; 6 tabs

  12. Present state of tandem superconductive booster of JAERI

    Energy Technology Data Exchange (ETDEWEB)

    Takeuchi, Suehiro; Matsuda, Makoto; Kanazawa, Shuhei; Yoshida, Tadashi; Ouchi, Isao; Shoji, Tokio [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1996-12-01

    The superconductive booster constructed rear-stage accelerator of the tandem accelerator of the Tokai Research Establishment, JAERI (Japan Atomic Energy Research Institute), was completed in construction of its whole system on October, 1993, and through its beam accelerating test and remodulation its design characteristics were established on September, 1994. From November, 1994 to April, 1995 a repulsion-forming nuclear isolation apparatus was installed to modulate at target room, and was begun to use on June, 1995. The beam reaccelerated at the booster was used mainly for nuclear spectroscopy experiment, a collaborative research was developed using mini-crystal balls made by collecting from University of Tsukuba and so forth. The accelerating part of the booster is a phase independent setting type Linac consisting of 40 niobium superconducting holes with 1/4 wave-length type and 130 MHz in frequency, in which a hole can form 5 MV/m of accelerating electric field for 4 W of radio frequency spent power of 0.75 MV of accelerating voltage per hole, to form 30 MV of voltage in a whole. 4 holes are contained into each 10 cryostats, respectively. In accelerating tests, Si, Cl, Ni, Ge, Ag, I and Au ions are accelerated to establish 30 mV of total accelerating voltage in its design value, which reaches to their expected energy characteristics. Its used days in this year are 25 days after beginning of its use, and operating days of the cooling apparatus was 135 days in total. (G.K.)

  13. TRStalker: an efficient heuristic for finding fuzzy tandem repeats.

    Science.gov (United States)

    Pellegrini, Marco; Renda, M Elena; Vecchio, Alessio

    2010-06-15

    Genomes in higher eukaryotic organisms contain a substantial amount of repeated sequences. Tandem Repeats (TRs) constitute a large class of repetitive sequences that are originated via phenomena such as replication slippage and are characterized by close spatial contiguity. They play an important role in several molecular regulatory mechanisms, and also in several diseases (e.g. in the group of trinucleotide repeat disorders). While for TRs with a low or medium level of divergence the current methods are rather effective, the problem of detecting TRs with higher divergence (fuzzy TRs) is still open. The detection of fuzzy TRs is propaedeutic to enriching our view of their role in regulatory mechanisms and diseases. Fuzzy TRs are also important as tools to shed light on the evolutionary history of the genome, where higher divergence correlates with more remote duplication events. We have developed an algorithm (christened TRStalker) with the aim of detecting efficiently TRs that are hard to detect because of their inherent fuzziness, due to high levels of base substitutions, insertions and deletions. To attain this goal, we developed heuristics to solve a Steiner version of the problem for which the fuzziness is measured with respect to a motif string not necessarily present in the input string. This problem is akin to the 'generalized median string' that is known to be an NP-hard problem. Experiments with both synthetic and biological sequences demonstrate that our method performs better than current state of the art for fuzzy TRs and that the fuzzy TRs of the type we detect are indeed present in important biological sequences. TRStalker will be integrated in the web-based TRs Discovery Service (TReaDS) at bioalgo.iit.cnr.it. Supplementary data are available at Bioinformatics online.

  14. Tandem Mass Spectrometry of Modified and Platinated Oligoribonucleotides

    Science.gov (United States)

    Nyakas, Adrien; Stucki, Silvan R.; Schürch, Stefan

    2011-05-01

    Therapeutic approaches for treatment of various diseases aim at the interruption of transcription or translation. Modified oligonucleotides, such as 2'- O-methyl- and methylphosphonate-derivatives, exhibit high resistance against cellular nucleases, thus rendering application for, e.g., antigene or antisense purposes possible. Other approaches are based on administration of cross-linking agents, such as cis-diamminedichloroplatinum(II) (cisplatin, DDP), which is still the most widely used anticancer drug worldwide. Due to the formation of 1,2-intrastrand cross links at adjacent guanines, replication of the double-strand is disturbed, thus resulting in significant cytotoxicity. Evidence for the gas-phase dissociation mechanism of platinated RNA is given, based on nano-electrospray ionization high-resolution multistage tandem mass spectrometry (MS n ). Confirmation was found by investigating the fragmentation pattern of platinated and unplatinated 2'-methoxy oligoribonucleotide hexamers and their corresponding methylphosphonate derivatives. Platinated 2'-methoxy oligoribonucleotides exhibit a similar gas-phase dissociation behavior as the corresponding DNA and RNA sequences, with the 3'-C-O bond adjacent to the vicinal guanines being cleaved preferentially, leading to wx-ion formation. By examination of the corresponding platinated methylphosphonate derivatives of the 2'-methoxy oligoribonucleotides, the key role of the negatively charged phosphate oxygen atoms in direct proximity to the guanines was proven. The significant alteration of fragmentation due to platination is demonstrated by comparison of the fragment ion patterns of unplatinated and platinated 2'- O-methyl- and 2'- O-methyl methylphosphonate oligoribonucleotides, and the results obtained by H/D exchange experiments.

  15. Telemetry component tests in the FN tandem terminal

    International Nuclear Information System (INIS)

    Bicek, J.J.; Billquis, P.J.; Yntema, J.L.

    1977-01-01

    When an electrostatic tandem accelerator is used primarily for heavy ion acceleration, numerous communication channels with the high voltage terminal are desirable. The ANL FN tandem operates at a tank pressure of 100 psi SF 6 at terminal voltages up to 9.5 MeV. A low powered He-Ne laser with 15 percent modulation has been successfully tested in the terminal under normal operating conditions. Such a system allows the transmission of information without the use of light guides. Multistranded light guides did not withstand voltage gradients as low as 0.4 MV/m. Single core light guides with a diameter of 0.5 mm have been successfully operated at voltage gradients in excess of 1.7 MV/m. In addition to the laser a microprocessor has also been tested in the tandem terminal. With suitable protection, an 8080 microprocessor and a programmable ROM operated successfully for several weeks under normal operating conditions

  16. Optical klystron FELs based on tandem electrostatic accelerators

    International Nuclear Information System (INIS)

    Gover, A.; Friedman, A.

    1989-01-01

    The operation of tandem electrostatic accelerator FELs in an optical klystron configuration makes it possible to take advantage of the high quality (low emittance and low energy spread) of the electron beam in electrostatic accelerators. With evolving microwiggler technology, state-of-the-art moderate energy (6-14-MeV) tandem electrostatic accelerators may be used for the development of highly coherent tunable radiation sources in the entire IR region. The authors present the general design considerations and the predicted operating characteristics of such devices and refer in specifics to a design of a 10-1000-μm FEL based on the parameters of a 5-6-MeV high current tandem accelerator. The operating wavelength of FELs is determined by the Doppler shift formula

  17. Study of Tandem Accelerator Technology and Its Prospects

    International Nuclear Information System (INIS)

    Sigit-Hariyanto; Sudjatmoko; Djoko-S-Pudjorahardjo; Suryadi; Widdi-Usada; Suprapto; Djasiman; Tono-Wibowo; Agus-Purwadi

    2000-01-01

    Tandem accelerator is an ion acceleration tool in which negative ions injected in the accelerator tube and stripped to become positive ions, then accelerated by electrostatic high voltage such that its energy is multiplied. In this paper, we describe the prospect of accelerator application briefly in agriculture and biotechnology, industry, health and medicine, environment fields. Technical study on tandem accelerator included SNICS and alphatross ion sources, acceleration system and stripper system. The study result for many kinds of negative ions and its current which should be injected in the accelerator tube and the output of tandem accelerator H + , and the distribution of C + , Ni + , Au + , Br + ion on varying charge state is shown. (author)

  18. Tandem photovoltaic solar cells and increased solar energy conversion efficiency

    Science.gov (United States)

    Loferski, J. J.

    1976-01-01

    Tandem photovoltaic cells, as proposed by Jackson (1955) to increase the efficiency of solar energy conversion, involve the construction of a system of stacked p/n homojunction photovoltaic cells composed of different semiconductors. It had been pointed out by critics, however, that the total power which could be extracted from the cells in the stack placed side by side was substantially greater than the power obtained from the stacked cells. A reexamination of the tandem cell concept in view of the development of the past few years is conducted. It is concluded that the use of tandem cell systems in flat plate collectors, as originally envisioned by Jackson, may yet become feasible as a result of the development of economically acceptable solar cells for large scale terrestrial power generation.

  19. Technical specification for a 25 MV tandem electrostatic accelerator

    International Nuclear Information System (INIS)

    Jones, C.M.; Biggerstaff, J.A.; Blair, J.K.; Ball, J.B.; Larson, J.D.; Martin, J.A.; McConnell, J.W.; Milner, W.T.; Murray, J.A.; Ziegler, N.F.

    1975-08-01

    Specifications are given for an accelerator system to consist of a 25 MV tandem electrostatic accelerator and specified ancillary equipment, including an injector, a beam transport system, a vacuum system, a control system, and a system for storage of the insulating gas and transport of the gas to and from the accelerator. The insulating gas shall be SF 6 . The tandem electrostatic accelerator shall be vertical in orientation and of folded construction, and shall be installed in a new structure adjacent to the Oak Ridge Isochronous Cyclotron. (auth)

  20. New uses for the Tandem Van de Graaff Accelerator

    International Nuclear Information System (INIS)

    Balcazar Garcia, M.

    1989-01-01

    The Tandem Van de Graaff is a very high resolution magnetic separator whose application offers a rich and virgin field for research in other areas. This work presents some of the radioisotopes of interest; their mechanisms of formation and this relationship with studies in solar activity variations in earth magnetic fields, carbon cycle dynamics, archaeological dating, dating of aquifer deposits, solar influences on variations in earth climates and the mechanics of tectonic plates. Discussed are the advantages of the Tandem utilization as an isotope separator compared with conventional techniques. (Author)

  1. Overview and direction in the tandem mirror program

    International Nuclear Information System (INIS)

    Thomassen, K.I.

    1983-04-01

    There are two main thrusts to the tandem mirror program at the present time. One is to gather the experimental data base to verify the axicell thermal-barrier concept and the other to improve the end plugs for tandems. With such improvements one might approach the ideal fusion reactor, a simple solenoid of modular elements whose ends are but a modest perturbation on the configuration from both a cost and technological viewpoint. Progress toward these two goals is discussed here, and the directions to be taken in the immediate future are described

  2. Axisymmetric tandem mirror stabilized by a magnetic limiter

    International Nuclear Information System (INIS)

    Kesner, J.; Post, R.S.; Lane, B.

    1985-06-01

    In order to stabilize MHD-like, fast growing m = 1 fluctuations in the central cell of a tandem mirror we propose the introduction of a magnetic limiter. The magnetic limiter would create a ring null in the magnetic field. Electrons which enter the null can stream azimuthally and thereby ''short-circuit'' m = 1 fluctuations. Some pressure could be maintained on the separatrix flux surface by locating the null on a local magnetic maxima or by axial plugging. This scheme introduces the possibility of a fully axisymmetric tandem mirror

  3. Ohio University tandem Van de Graaff accelerator. Final report

    International Nuclear Information System (INIS)

    Lane, R.O.

    1977-11-01

    A summary is given of the work carried out at the John Edwards Tandem Accelerator Laboratory of Ohio University during the period 1970 to 1977 on studies of neutron-nucleus interactions and nuclear structure using neutrons as probes. This work utilizes the main and unique characteristic of the accelerator: high current, high voltage tandem. Certain applied areas were also studied, such as the production of short-lived isotopes for use in medical diagnoses, production of very high neutron intensity to observe possible sputtering effects, and proton induced x-ray emission with a microprobe beam

  4. Approach to the open advanced facilities initiative for innovation (strategic use by industry) at the University of Tsukuba, Tandem Accelerator Complex

    International Nuclear Information System (INIS)

    Sasa, K.; Tagishi, Y.; Naramoto, H.; Kudo, H.; Kita, E.

    2010-01-01

    The University of Tsukuba, Tandem Accelerator Complex (UTTAC) possesses the 12UD Pelletron tandem accelerator and the 1 MV Tandetron accelerator for University's inter-department education research. We have actively advanced collaborative researches with other research institutes and industrial users. Since the Open Advanced Facilities Initiative for Innovation by the Ministry of Education, Culture, Sports, Science and Technology started in 2007, 12 industrial experiments have been carried out at the UTTAC. This report describes efforts by University's accelerator facility to get industrial users. (author)

  5. A Study on Organic-Metal Halide Perovskite Film Morphology, Interfacial Layers, Tandem Applications, and Encapsulation

    Science.gov (United States)

    Fisher, Dallas A.

    Organic-metal halide perovskites have brought about a new wave of research in the photovoltaic community due to their ideally suited optical and electronic parameters. In less than a decade, perovskite solar cell performance has skyrocketed to unprecedented efficiencies with numerous reported methodologies. Perovskites face many challenges with high-quality film morphology, interfacial layers, and long-term stability. In this work, these active areas are explored through a combination of studies. First, the importance of perovskite film precursor ratios is explored with an in-depth study of carrier lifetime and solvent-grain effects. It was found that excess lead iodide precursor greatly improves the film morphology by reducing pinholes in the solar absorber. Dimethyl sulfoxide (DMSO) solvent was found to mend grains, as well as improve carrier lifetime and device performance, possibly by passivation of grain boundary traps. Second, applications of perovskite with tandem cells is investigated, with an emphasis for silicon devices. Perovskites can easily be integrated with silicon, which already has strong market presence. Additionally, both materials' bandgaps are ideally suited for maximum tandem efficiency. The silicon/perovskite tandem device structure necessitated the optimization of inverted (p-i-n) structure devices. PEDOT:PSS, copper oxide, and nickel oxide p-type layers were explored through a combination of photoluminescent, chemical reactivity, and solar simulation results. Results were hindered due to resistive ITO and rough silicon substrates, but tandem devices displayed Voc indicative of proper monolithic performance. Third, replacement of titanium dioxide n-type layer with iron oxide (Fe 2O3, common rust) was studied. Iron oxide experiences less ultraviolet instability than that of titanium dioxide under solar illumination. It was found that current density slightly decreased due to parasitic absorption from the rust, but that open circuit voltage

  6. MSOAR 2.0: Incorporating tandem duplications into ortholog assignment based on genome rearrangement

    Directory of Open Access Journals (Sweden)

    Zhang Liqing

    2010-01-01

    Full Text Available Abstract Background Ortholog assignment is a critical and fundamental problem in comparative genomics, since orthologs are considered to be functional counterparts in different species and can be used to infer molecular functions of one species from those of other species. MSOAR is a recently developed high-throughput system for assigning one-to-one orthologs between closely related species on a genome scale. It attempts to reconstruct the evolutionary history of input genomes in terms of genome rearrangement and gene duplication events. It assumes that a gene duplication event inserts a duplicated gene into the genome of interest at a random location (i.e., the random duplication model. However, in practice, biologists believe that genes are often duplicated by tandem duplications, where a duplicated gene is located next to the original copy (i.e., the tandem duplication model. Results In this paper, we develop MSOAR 2.0, an improved system for one-to-one ortholog assignment. For a pair of input genomes, the system first focuses on the tandemly duplicated genes of each genome and tries to identify among them those that were duplicated after the speciation (i.e., the so-called inparalogs, using a simple phylogenetic tree reconciliation method. For each such set of tandemly duplicated inparalogs, all but one gene will be deleted from the concerned genome (because they cannot possibly appear in any one-to-one ortholog pairs, and MSOAR is invoked. Using both simulated and real data experiments, we show that MSOAR 2.0 is able to achieve a better sensitivity and specificity than MSOAR. In comparison with the well-known genome-scale ortholog assignment tool InParanoid, Ensembl ortholog database, and the orthology information extracted from the well-known whole-genome multiple alignment program MultiZ, MSOAR 2.0 shows the highest sensitivity. Although the specificity of MSOAR 2.0 is slightly worse than that of InParanoid in the real data experiments

  7. Dinuclear Tetrapyrazolyl Palladium Complexes Exhibiting Facile Tandem Transfer Hydrogenation/Suzuki Coupling Reaction of Fluoroarylketone

    KAUST Repository

    Dehury, Niranjan; Maity, Niladri; Tripathy, Suman Kumar; Basset, Jean-Marie; Patra, Srikanta

    2016-01-01

    Herein, we report an unprecedented example of dinuclear pyrazolyl-based Pd complexes exhibiting facile tandem catalysis for fluoroarylketone: Tetrapyrazolyl di-palladium complexes with varying Pd-Pd distances efficiently catalyze the tandem reaction

  8. Hybrid tandem quantum dot/organic photovoltaic cells with complementary near infrared absorption

    KAUST Repository

    Kim, Taesoo; Palmiano, Elenita; Liang, Ru-Ze; Hu, Hanlin; Banavoth, Murali; Kirmani, Ahmad R.; Firdaus, Yuliar; Gao, Yangqin; Sheikh, Arif D.; Yuan, Mingjian; Mohammed, Omar F.; Hoogland, Sjoerd; Beaujuge, Pierre; Sargent, Edward H.; Amassian, Aram

    2017-01-01

    Monolithically integrated hybrid tandem solar cells that effectively combine solution-processed colloidal quantum dot (CQD) and organic bulk heterojunction subcells to achieve tandem performance that surpasses the individual subcell efficiencies

  9. Stern-Gerlach Experiments and Complex Numbers in Quantum Physics

    OpenAIRE

    Sivakumar, S.

    2012-01-01

    It is often stated that complex numbers are essential in quantum theory. In this article, the need for complex numbers in quantum theory is motivated using the results of tandem Stern-Gerlach experiments

  10. The ''Kinetic Stabilizer'': A Simpler Tandem Mirror Confinement?

    International Nuclear Information System (INIS)

    Post, R.F.

    2000-01-01

    In the search for better approaches to magnetic fusion it is important to keep in mind the lessons learned in the 50 years that fusion plasma confinement has been studied. One of the lessons learned is that ''closed'' and ''open'' fusion devices differ fundamentally with respect to an important property of their confinement, as follows: Without known exception closed systems such as the tokamak, the stellarator, or the reversed-field pinch, have been found to have their confinement times limited by non-classical, i.e., turbulence-related, processes, leading to the requirement that such systems must be scaled-up in dimensions to sizes much larger than would be the case in the absence of turbulence. By contrast, from the earliest days of fusion research, it has been demonstrated that open magnetic systems of the mirror variety can achieve confinement times close to that associated with classical, i.e., collisional, processes. While these good results have been obtained in both axially symmetric fields and in non-axisymmetric fields, the clearest cases have been those in which the confining fields are solenoidal and axially symmetric. These observations, i.e., of confinement not enhanced by turbulence, can be traced theoretically to such factors as the absence of parallel currents in the plasma, and to the constraints on particle drifts imposed by the adiabatic invariants governing particle confinement in axisymmetric open systems. In the past the MHD instability of axially symmetric open systems has been seen as a barrier to their use. However, theory predicts MHD-stable confinement is achievable if sufficient plasma is present in the ''good curvature'' regions outside the mirrors. This theory has been confirmed by experiments on the Gas Dynamic Trap mirror-based experiment at Novosibirsk, In this paper a new way of exploiting this stabilizing principle, involving creating a localized ''stabilizer plasma'' outside a mirror, will be discussed. To create this plasma

  11. Quantitative Caffeine Analysis Using a Surface Sampling Probe Electrospray Ionization Tandem Mass Spectrometry System

    Energy Technology Data Exchange (ETDEWEB)

    Ford, Michael J [ORNL; Deibel, Michael A. [Earlham College; Tomkins, Bruce A [ORNL; Van Berkel, Gary J [ORNL

    2005-01-01

    Quantitative determination of caffeine on reversed-phase C8 thin-layer chromatography plates using a surface sampling electrospray ionization system with tandem mass spectrometry detection is reported. The thin-layer chromatography/electrospray tandem mass spectrometry method employed a deuterium-labeled caffeine internal standard and selected reaction monitoring detection. Up to nine parallel caffeine bands on a single plate were sampled in a single surface scanning experiment requiring 35 min at a surface scan rate of 44 {mu}m/s. A reversed-phase HPLC/UV caffeine assay was developed in parallel to assess the mass spectrometry method performance. Limits of detection for the HPLC/UV and thin-layer chromatography/electrospray tandem mass spectrometry methods determined from the calibration curve statistics were 0.20 ng injected (0.50 {mu}L) and 1.0 ng spotted on the plate, respectively. Spike recoveries with standards and real samples ranged between 97 and 106% for both methods. The caffeine content of three diet soft drinks (Diet Coke, Diet Cherry Coke, Diet Pepsi) and three diet sport drinks (Diet Turbo Tea, Speed Stack Grape, Speed Stack Fruit Punch) was measured. The HPLC/UV and mass spectrometry determinations were in general agreement, and these values were consistent with the quoted values for two of the three diet colas. In the case of Diet Cherry Coke and the diet sports drinks, the determined caffeine amounts using both methods were consistently higher (by 8% or more) than the literature values.

  12. Protein Inference from the Integration of Tandem MS Data and Interactome Networks.

    Science.gov (United States)

    Zhong, Jiancheng; Wang, Jianxing; Ding, Xiaojun; Zhang, Zhen; Li, Min; Wu, Fang-Xiang; Pan, Yi

    2017-01-01

    Since proteins are digested into a mixture of peptides in the preprocessing step of tandem mass spectrometry (MS), it is difficult to determine which specific protein a shared peptide belongs to. In recent studies, besides tandem MS data and peptide identification information, some other information is exploited to infer proteins. Different from the methods which first use only tandem MS data to infer proteins and then use network information to refine them, this study proposes a protein inference method named TMSIN, which uses interactome networks directly. As two interacting proteins should co-exist, it is reasonable to assume that if one of the interacting proteins is confidently inferred in a sample, its interacting partners should have a high probability in the same sample, too. Therefore, we can use the neighborhood information of a protein in an interactome network to adjust the probability that the shared peptide belongs to the protein. In TMSIN, a multi-weighted graph is constructed by incorporating the bipartite graph with interactome network information, where the bipartite graph is built with the peptide identification information. Based on multi-weighted graphs, TMSIN adopts an iterative workflow to infer proteins. At each iterative step, the probability that a shared peptide belongs to a specific protein is calculated by using the Bayes' law based on the neighbor protein support scores of each protein which are mapped by the shared peptides. We carried out experiments on yeast data and human data to evaluate the performance of TMSIN in terms of ROC, q-value, and accuracy. The experimental results show that AUC scores yielded by TMSIN are 0.742 and 0.874 in yeast dataset and human dataset, respectively, and TMSIN yields the maximum number of true positives when q-value less than or equal to 0.05. The overlap analysis shows that TMSIN is an effective complementary approach for protein inference.

  13. Investigation of beam transmission in A 9SDH-2 3.0 MV NEC pelletron tandem accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Deoli, Naresh T.; Kummari, Venkata C.; Pacheco, Jose L.; Duggan, Jerome L.; Glass, Gary A.; McDaniel, Floyd D.; Reinert, Tilo; Rout, Bibhudutta; Weathers, Duncan L. [Ion Beam Modification And Analysis Laboratory, Department of Physics, University of North Texas, Denton, Texas 76203 (United States)

    2013-04-19

    Electrostatic tandem accelerators are widely used to accelerate ions for experiments in materials science such as high energy ion implantation, materials modification, and analyses. Many applications require high beam current as well as high beam brightness at the target; thus, maximizing the beam transmission through such electrostatic accelerators becomes important. The Ion Beam Modification and Analysis Laboratory (IBMAL) at University of North Texas is equipped with four accelerators, one of which is a 9SDH-2 3.0 MV National Electrostatic Corporation (NEC) Pelletron Registered-Sign tandem accelerator. The tandem accelerator is equipped with three ion sources: one radio frequency-He ion source (Alphatross) and two ion sources of Cs-sputter type, the SNICS II (Source of Negative Ions by Cesium Sputtering) and a Cs-sputter source for trace-element accelerator based mass spectrometry. This work presents a detailed study of the beam transmission of hydrogen, silicon, and silver ions through the accelerator using the SNICS ion source with injection energies ranging from 20 keV to 70 keV. The beam transmission is quantified for three different terminal voltages: 1.5 MV, 2.0 MV and 2.5 MV. For a given terminal voltage, it has been found that beam transmission is strongly dependent on the ion source injector potential. Details of experiments and data analysis are presented.

  14. Tandem neopentyl glycol maltosides (TNMs) for membrane protein stabilisation†

    OpenAIRE

    Bae, Hyoung Eun; Mortensen, Jonas S.; Ribeiro, Orquidea; Du, Yang; Ehsan, Muhammad; Kobilka, Brian K.; Loland, Claus J.; Byrne, Bernadette; Chae, Pil Seok

    2016-01-01

    A novel class of detergents, designated tandem neopentyl glycol maltosides (TNMs), were evaluated with four target membrane proteins. The best detergent varied depending on the target, but TNM-C12L and TNM-C11S were notable for their ability to confer increased membrane protein stability compared to DDM. These agents have potential for use in membrane protein research.

  15. Tandem neopentyl glycol maltosides (TNMs) for membrane protein stabilisation.

    Science.gov (United States)

    Bae, Hyoung Eun; Mortensen, Jonas S; Ribeiro, Orquidea; Du, Yang; Ehsan, Muhammad; Kobilka, Brian K; Loland, Claus J; Byrne, Bernadette; Chae, Pil Seok

    2016-10-04

    A novel class of detergents, designated tandem neopentyl glycol maltosides (TNMs), were evaluated with four target membrane proteins. The best detergent varied depending on the target, but TNM-C12L and TNM-C11S were notable for their ability to confer increased membrane protein stability compared to DDM. These agents have potential for use in membrane protein research.

  16. Tandem neopentyl glycol maltosides (TNMs) for membrane protein stabilisation†

    Science.gov (United States)

    Bae, Hyoung Eun; Mortensen, Jonas S.; Ribeiro, Orquidea; Du, Yang; Ehsan, Muhammad; Kobilka, Brian K.; Loland, Claus J.; Byrne, Bernadette

    2017-01-01

    A novel class of detergents, designated tandem neopentyl glycol maltosides (TNMs), were evaluated with four target membrane proteins. The best detergent varied depending on the target, but TNM-C12L and TNM-C11S were notable for their ability to confer increased membrane protein stability compared to DDM. These agents have potential for use in membrane protein research. PMID:27711401

  17. Tandem neopentyl glycol maltosides (TNMs) for membrane protein stabilisation

    DEFF Research Database (Denmark)

    Bae, Hyoung Eun; Mortensen, Jonas S; Ribeiro, Orquidea

    2016-01-01

    A novel class of detergents, designated tandem neopentyl glycol maltosides (TNMs), were evaluated with four target membrane proteins. The best detergent varied depending on the target, but TNM-C12L and TNM-C11S were notable for their ability to confer increased membrane protein stability compared...

  18. Accelerator mass analysis at tandem accelerator in Kyoto University

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, Masanobu; Tazawa, Yuji; Matsumoto, Hiroshi; Hirose, Masanori [Kyoto Univ. (Japan). Faculty of Science; Ogino, Koya; Kohno, Masuchika; Funaba, Hiroyuki

    1996-12-01

    Tandem accelerator in Science Faculty, Kyoto University was renewed from 5 MV in the highest terminal voltage of Van de Graaff to 8 MV of Peletron in 1992. And, AMS effective for cosmic ray, dating, environment measurement and so forth is determined to a column of collaborative studies by universities and institutes in Japan. On this renewal, because of using high energy beam transportation of the present tandem accelerator, super high sensitivity measurement of long half-life radioactive isotopes of heavy elements such as {sup 36}Cl, {sup 41}Ca, {sup 129}I and so forth is aimed, although having some limitations due to small magnet. The accelerator is active in characteristics of the middle size tandem accelerator, and developing {sup 14}C measurement for its standard technology, as aiming at {sup 36}Cl measurement, at first. As a result, in this tandem accelerator stable and high beam transmittance could be obtained by adding a slit at negative ion source to make emittance of incident beam smaller. {sup 14}C/{sup 12}C ratio of Modan`s sample obtained by graphitizing NBS oxalic acid and Ded`s sample consisting of mineral graphite produced in Sri Lanka are measured to confirm better reproductivity of this system. Future development of successive incident method is planned to test actual carbon samples. (G.K.)

  19. Note on a tandem queue with delayed server release

    NARCIS (Netherlands)

    Nawijn, W.M.

    2000-01-01

    We consider a tandem queue with two stations. The first station is an $s$-server queue with Poisson arrivals and exponential service times. After terminating his service in the first station, a customer enters the second station to require service at a single server, while in the meantime he is

  20. Finding all sorting tandem duplication random loss operations

    DEFF Research Database (Denmark)

    Bernt, Matthias; Chen, Kuan Yu; Chen, Ming Chiang

    2011-01-01

    A tandem duplication random loss (TDRL) operation duplicates a contiguous segment of genes, followed by the random loss of one copy of each of the duplicated genes. Although the importance of this operation is founded by several recent biological studies, it has been investigated only rarely from...

  1. Y-Chromosome short tandem repeat, typing technology, locus ...

    African Journals Online (AJOL)

    Aghomotsegin

    2015-07-08

    Jul 8, 2015 ... Y-Chromosome short tandem repeat, typing technology, locus information and allele frequency in different population: A review. Muhanned Abdulhasan Kareem1, Ameera Omran Hussein2 and Imad Hadi Hameed2*. 1Babylon University, Centre of Environmental Research, Hilla City, Iraq. 2Department of ...

  2. Genetic Analysis of Eight X-Chromosomal Short Tandem Repeat ...

    African Journals Online (AJOL)

    X-Chromosome short tandem repeat (STR) typing can complement existing DNA profiling protocols and can also offer useful information in cases of complex kinship analysis. This is the first population study of 8 X-linked STRs in Iraq. The purpose of this work was to provide a basic data of allele and haplotype frequency for ...

  3. X-Chromosome short tandem repeat, advantages and typing ...

    African Journals Online (AJOL)

    Microsatellites of the X-chromosome have been increasingly studied in recent years as a useful tool in forensic analysis. This review describes some details of X-chromosomal short tandem repeat (STR) analysis. Among them are: microsatellites, amplification using polymerase chain reaction (PCR) of STRs, PCR product ...

  4. Near-optimal switching strategies for a tandem queue

    NARCIS (Netherlands)

    van Leeuwen, D.; Núñez-Queija, R.; Boucherie, R.J.; van Dijk, N.M.

    2017-01-01

    Motivated by various applications in logistics, road traffic and production management, we investigate two versions of a tandem queueing model in which the service rate of the first queue can be controlled. The objective is to keep the mean number of jobs in the second queue as low as possible,

  5. Near-optimal switching strategies for a tandem queue

    NARCIS (Netherlands)

    D. van Leeuwen (Daphne); R. Núñez Queija (Rudesindo)

    2017-01-01

    textabstractMotivated by various applications in logistics, road traffic and production management, we investigate two versions of a tandem queueing model in which the service rate of the first queue can be controlled. The objective is to keep the mean number of jobs in the second queue as low as

  6. Ultimate performance of polymer: Fullerene bulk heterojunction tandem solar cells

    NARCIS (Netherlands)

    Kotlarski, J.D.; Blom, P.W.M.

    2011-01-01

    We present the model calculations to explore the potential of polymer:fullerene tandem solar cells. As an approach we use a combined optical and electrical device model, where the absorption profiles are used as starting point for the numerical current-voltage calculations. With this model a maximum

  7. Analysis of posttranslational modifications of proteins by tandem mass spectrometry

    DEFF Research Database (Denmark)

    Larsen, Martin Røssel; Trelle, Morten B; Thingholm, Tine E

    2006-01-01

    -temporal distribution in cells and tissues. Most PTMs can be detected by protein and peptide analysis by mass spectrometry (MS), either as a mass increment or a mass deficit relative to the nascent unmodified protein. Tandem mass spectrometry (MS/MS) provides a series of analytical features that are highly useful...

  8. Beam transport calculations for the EN tandem installation

    International Nuclear Information System (INIS)

    Sparks, R.J.

    1980-12-01

    Transport of a charged particle beam through the new EN tandem accelerator installation of the Institute of Nuclear Sciences has been analysed using simplified mathematical models. The purpose is to identify the factors affecting transmission of the beam, and to arrive at a design for the system to inject the beam into the accelerator

  9. Biological effects of tandem shock waves demonstrated on magnetic resonance

    Czech Academy of Sciences Publication Activity Database

    Beneš, J.; Zeman, J.; Poučková, P.; Zadinová, M.; Šunka, Pavel; Lukeš, Petr

    Roč. 113, č. 6 ( 2012 ), s. 335-338 ISSN 0006-9248 R&D Projects: GA ČR GA202/09/1151 Institutional research plan: CEZ:AV0Z20430508 Keywords : electrical discharges in water * focused shock waves * cavitations * tandem shock waves Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 0.472, year: 2012

  10. Cable systems for experimental facilities in JAERI TANDEM ACCELERATOR BUILDING

    International Nuclear Information System (INIS)

    Tukihashi, Yoshihiro; Yoshida, Tadashi; Takekoshi, Eiko

    1979-03-01

    Measuring cable systems for experimental facilities in JAERI TANDEM ACCELERATOR BUILDING were completed recently. Measures are taken to prevent penetration of noises into the measuring systems. The cable systems are described in detail, including power supplies and grounding for the measuring systems. (author)

  11. Accelerator mass spectrometry with a coupled tandem-linac system

    International Nuclear Information System (INIS)

    Kutschera, W.

    1984-01-01

    A coupled system provides higher energies, which allows one to extend AMS to hitherto untouched mass regions. Another important argument is that the complexity, although bothersome for the operation, increases the selectivity of detecting a particular isotope. The higher-energy argument holds for any heavy-ion accelerator which is capable of delivering higher energy than a tandem. The present use of tandem-linac combinations for AMS, rather than cyclotrons, linacs or combinations of these machines, has mainly to do with the fact that this technique was almost exclusively developed around tandem accelerators. Therefore the tandem-linac combination is a natural extension to higher energies. The use of negative ions has some particular advantages in suppressing background from unwanted elements that do not form stable negative ions (e.g., N, Mg, Ar). On the other hand, this limits the detection of isotopes to elements which do form negative ions. For particular problems it may therefore be advantageous to use a positive-ion machine. What really matters most for choosing one or the other machine is to what extent the entire accelerator system can be operated in a truly quantiative way from the ion source to the detection system. 20 references, 4 figures

  12. Stochastic motion of particles in tandem mirror devices

    International Nuclear Information System (INIS)

    Ichikawa, Y.H.; Kamimura, T.

    1982-01-01

    Stochastic motion of particles in tandem mirror devices is examined on basis of a nonlinear mapping of particle positions on the equatorial plane. Local stability analysis provides detailed informations on particle trajectories. The rate of stochastic plasma diffusion is estimated from numerical observations of motions of particles over a large number of time steps. (author)

  13. Concurrent control system for the JAERI tandem accelerator

    International Nuclear Information System (INIS)

    Hanashima, S.; Shoji, T.; Horie, K.; Tsukihashi, Y.

    1992-01-01

    Concurrent processing with a multiprocessor system is introduced to the particle accelerator control system region. The control system is a good application in both logical and physical aspects. A renewal plan of the control system for the JAERI tandem accelerator is discussed. (author)

  14. Characteristics of KUMM Tandem Electrostatic Accelerator 5SDH-2

    International Nuclear Information System (INIS)

    Kitamura, Akira; Furuyama, Yuichi; Taniike, Akira; Kubota, Naoyoshi

    1998-01-01

    The KUMM Tandem Electrostatic Accelerator was heavily damaged by the Hanshin Earthquake in Jan. 1995, and the renewed version 5SDH-2 was installed in 1996. The fundamental characteristics of the renewed system is reported together with the system composition. (author)

  15. Scaling of the optical parameters for the JAERI tandem accelerator

    International Nuclear Information System (INIS)

    Hanashima, S.; Minehara, E.

    1986-01-01

    A scaling rule of the beam optical parameters was adopted for computer-aided beam transport in the JAERI tandem accelerator. Tests have shown that the computer program can transport a specified beam in a short time using a reference parameter set. Problems of ion source control and accuracy of the optical devices are also discussed

  16. State-dependent importance sampling for a slowdown tandem queue

    NARCIS (Netherlands)

    Miretskiy, D.I.; Scheinhardt, W.R.W.; Mandjes, M.R.H.

    2011-01-01

    In this paper we investigate an advanced variant of the classical (Jackson) tandem queue, viz. a two-node system with server slowdown. By this mechanism, the service speed of the upstream queue is reduced as soon as the number of jobs in the downstream queue reaches some pre-specified threshold. We

  17. A tandem queue with server slow-down and blocking

    NARCIS (Netherlands)

    van Foreest, N.D.; van Ommeren, Jan C.W.; Mandjes, M.R.H.; Scheinhardt, Willem R.W.

    2005-01-01

    We consider two variants of a two-station tandem network with blocking. In both variants the first server ceases to work when the queue length at the second station hits a 'blocking threshold.' In addition, in variant 2 the first server decreases its service rate when the second queue exceeds a

  18. A tandem queue with server slow-down and blocking.

    NARCIS (Netherlands)

    van Foreest, N.; van Ommeren, J.C.; Mandjes, M.R.H.; Scheinhardt, W.

    2005-01-01

    We consider two variants of a two-station tandem network with blocking. In both variants the first server ceases to work when the queue length at the second station hits a 'blocking threshold.' In addition, in variant 2 the first server decreases its service rate when the second queue exceeds a

  19. The nuclear structure facility tandem at Daresbury laboratory

    International Nuclear Information System (INIS)

    Voss, R.G.P.

    1976-01-01

    A 30MV tandem electrostatic accelerator for ions of all types, including heavy ions, is being built at Daresbury Laboratory. Construction is well advanced, and considerable effort is continuing to be devoted to R and D programme into the technology of electrostatic accelerators

  20. Optochemokine Tandem for Light-Control of Intracellular Ca2.

    Directory of Open Access Journals (Sweden)

    Katrin Feldbauer

    Full Text Available An optochemokine tandem was developed to control the release of calcium from endosomes into the cytosol by light and to analyze the internalization kinetics of G-protein coupled receptors (GPCRs by electrophysiology. A previously constructed rhodopsin tandem was re-engineered to combine the light-gated Ca2+-permeable cation channel Channelrhodopsin-2(L132C, CatCh, with the chemokine receptor CXCR4 in a functional tandem protein tCXCR4/CatCh. The GPCR was used as a shuttle protein to displace CatCh from the plasma membrane into intracellular areas. As shown by patch-clamp measurements and confocal laser scanning microscopy, heterologously expressed tCXCR4/CatCh was internalized via the endocytic SDF1/CXCR4 signaling pathway. The kinetics of internalization could be followed electrophysiologically via the amplitude of the CatCh signal. The light-induced release of Ca2+ by tandem endosomes into the cytosol via CatCh was visualized using the Ca2+-sensitive dyes rhod2 and rhod2-AM showing an increase of intracellular Ca2+ in response to light.

  1. A New Synthetic Route to Dihydrobenzopyran Via Tandem Demethylation Cyclisation

    Directory of Open Access Journals (Sweden)

    G. Shanmugam

    2000-06-01

    Full Text Available A tandem demethylation-cyclisation reaction resulting in the formation of pyran rings using AlCl3/EtSH reagent under mild reaction conditions is reported. X-ray diffraction studies on the intermediate support the suggested mechanism.

  2. Interim report on the tandem mirror hybrid design study

    International Nuclear Information System (INIS)

    Moir, R.W.

    1979-01-01

    The initial phase of a 2-year design study of a tandem mirror fusion reactor is presented. The following chapters are included: (1) mechanical design of the plant; (2) plasma physics; (3) blanket design; (4) magnet design; (5) injector design; (6) direct convertor design; (7) balance of plant design; (8) fission burner reactor; (9) environment and safety; and (10) economic analysis

  3. State-dependent importance sampling for a Jackson tandem network

    NARCIS (Netherlands)

    Miretskiy, D.I.; Scheinhardt, W.R.W.; Mandjes, M.R.H.

    2008-01-01

    This paper considers importance sampling as a tool for rare-event simulation. The focus is on estimating the probability of overflow in the downstream queue of a Jacksonian two-node tandem queue – it is known that in this setting ‘traditional’ stateindependent importance-sampling distributions

  4. State-dependent importance sampling for a Jackson tandem network

    NARCIS (Netherlands)

    D.I. Miretskiy; W.R.W. Scheinhardt (Werner); M.R.H. Mandjes (Michel)

    2008-01-01

    htmlabstractThis paper considers importance sampling as a tool for rare-event simulation. The focus is on estimating the probability of overflow in the downstream queue of a Jacksonian two-node tandem queue – it is known that in this setting ‘traditional’ stateindependent importance-sampling

  5. Multiresidue analysis of 47 pesticides in cooked wheat flour and polished rice by liquid chromatography with tandem mass spectrometry.

    Science.gov (United States)

    Lee, Sung Jung; Park, Hyeong Jin; Kim, Wooseong; Jin, Jong Sung; Abd El-Aty, A M; Shim, Jae-Han; Shin, Sung Chul

    2009-04-01

    Liquid chromatography in conjunction with tandem mass spectrometry was used to directly quantify of 47 pesticide residues from cooked wheat flour and polished rice, which are the most widely consumed cereals in the Republic of Korea. The sample clean-up was carried out according to the method established by the Korea Food and Drug Administration. The mobile phase for liquid chromatography separation consisted of water and 5 mm methanolic ammonium formate. Tandem mass spectroscopy experiments were performed in electrospray ionization positive mode and the multiple reaction monitoring mode. The matrix effects estimated for the 47 pesticides had a mean value of 99% and ranged from 45 to 147%. High recoveries (70-140%) and relative standard deviations (flour and polished rice samples. Of the screened pesticide residues, only tricyclazole and fenobucarb were found in polished rice samples. However, no samples contained residues above the MRL established by the Korea Food and Drug Administration.

  6. Efficient organic tandem solar cells based on small molecules

    Energy Technology Data Exchange (ETDEWEB)

    Riede, Moritz; Widmer, Johannes; Timmreck, Ronny; Wynands, David; Leo, Karl [Institut fuer Angewandte Photophysik, Technische Universitaet Dresden, George-Baehr-Str. 1, 01069 Dresden (Germany); Uhrich, Christian; Schwartz, Gregor; Gnehr, Wolf-Michael; Hildebrandt, Dirk; Weiss, Andre; Pfeiffer, Martin [Heliatek GmbH, Treidlerstr. 3, 01139 Dresden (Germany); Hwang, Jaehyung; Sundarraj, Sudhakar; Erk, Peter [BASF SE, GVC/E-J542, 67056 Ludwigshafen (Germany)

    2011-08-23

    In this paper, two vacuum processed single heterojunction organic solar cells with complementary absorption are described and the construction and optimization of tandem solar cells based on the combination of these heterojunctions demonstrated. The red-absorbing heterojunction consists of C{sub 60} and a fluorinated zinc phthalocyanine derivative (F4-ZnPc) that leads to a 0.1-0.15 V higher open circuit voltage V{sub oc} than the commonly used ZnPc. The second heterojunction incorporates C{sub 60} and a dicyanovinyl-capped sexithiophene derivative (DCV6T) that mainly absorbs in the green. The combination of both heterojunctions into one tandem solar cell leads to an absorption over the whole visible range of the sun spectrum. Thickness variations of the transparent p-doped optical spacer between both subcells in the tandem solar cell is shown to lead to a significant change in short circuit current density j{sub sc} due to optical interference effects, whereas V{sub oc} and fill factor are hardly affected. The maximum efficiency {eta} of about 5.6% is found for a spacer thickness of 150-165 nm. Based on the optimized 165nm thick spacer, effects of intensity and angle of illumination, and temperature on a tandem device are investigated. Variations in illumination intensity lead to a linear change in j{sub sc} over three orders of magnitude and a nearly constant {eta} in the range of 30 to 310 mW cm{sup -2}. Despite the stacked heterojunctions, the performance of the tandem device is robust against different illumination angles: j{sub sc} and {eta} closely follow a cosine behavior between 0 and 70 . Investigations of the temperature behavior of the tandem device show an increase in {eta} of 0.016 percentage points per Kelvin between -20 C and 25 C followed by a plateau up to 50 C. Finally, further optimization of the tandem stack results in a certified {eta} of (6.07 {+-} 0.24)% on (1.9893 {+-} 0.0060)cm{sup 2} (Fraunhofer ISE), i.e., areas large enough to be of

  7. Annual report of Department of Research Reactor and Tandem Accelerator, JFY2007. Operation, utilization and technical development of JRR-3, JRR-4, NSRR and tandem accelerator

    International Nuclear Information System (INIS)

    Miyazaki, Osamu; Awa, Yasuaki; Isaka, Koji; Kutsukake, Kenichi; Komeda, Masao; Shibata, Ko; Hiyama, Kazuhisa; Suzuki, Mayu; Sone, Takuya; Ohuchi, Tomoaki; Terakado, Yuichi; Sataka, Masao

    2009-06-01

    The Department of Research Reactors and Tandem Accelerator is in charge of the operation, utilization and technical development of JRR-3(Japan Research Reactor-3), JRR-4(Japan Research Reactor-4), NSRR(Nuclear Safety Research Reactor) and Tandem Accelerator. This annual report describes a summary of activities of services and technical developments carried out in the period between April 1, 2007 and March 31, 2008. The activities were categorized into five service/development fields: (1) Operation and maintenance of research reactors and tandem accelerator. (2) Utilization of research reactors and tandem accelerator. (3) Upgrading of utilization techniques of research reactors and tandem accelerator. (4) Safety administration for research reactors and tandem accelerator. (5) International cooperation. Also contained are lists of publications, meetings, granted permissions on lows and regulations concerning atomic energy, commendation, plans and outcomes in service and technical developments and so on. (author)

  8. Annual report of Department of Research Reactor and Tandem Accelerator, JFY2010. Operation, utilization and technical development of JRR-3, JRR-4, NSRR and Tandem Accelerator

    International Nuclear Information System (INIS)

    Ishii, Tetsuro; Nakamura, Kiyoshi; Kawamata, Satoshi; Yamada, Yusuke; Kawashima, Kazuhiro; Asozu, Takuhiro; Nakamura, Takemi; Arai, Masaji; Yoshinari, Shuji; Sataka, Masao

    2012-03-01

    The Department of Research Reactors and Tandem Accelerator is in charge of the operation, utilization and technical development of JRR-3(Japan Research Reactor No.3), JRR-4(Japan Research Reactor No.4), NSRR(Nuclear Safety Research Reactor) and Tandem Accelerator. This annual report describes a summary of activities of services and technical developments carried out in the period between April 1, 2010 and March 31, 2011. The activities were categorized into five service/development fields: (1) Operation and maintenance of research reactors and tandem accelerator, (2) Utilization of research reactors and tandem accelerator, (3) Upgrading of utilization techniques of research reactors and tandem accelerator, (4) Safety administration for research reactors and tandem accelerator, (5) International cooperation. Also contained are lists of publications, meetings, granted permissions on lows and regulations concerning atomic energy, commendation, outcomes in service and technical developments and so on. (author)

  9. Development of an advanced spacecraft tandem mass spectrometer

    Science.gov (United States)

    Drew, Russell C.

    1992-03-01

    The purpose of this research was to apply current advanced technology in electronics and materials to the development of a miniaturized Tandem Mass Spectrometer that would have the potential for future development into a package suitable for spacecraft use. The mass spectrometer to be used as a basis for the tandem instrument would be a magnetic sector instrument, of Nier-Johnson configuration, as used on the Viking Mars Lander mission. This instrument configuration would then be matched with a suitable second stage MS to provide the benefits of tandem MS operation for rapid identification of unknown organic compounds. This tandem instrument is configured with a newly designed GC system to aid in separation of complex mixtures prior to MS analysis. A number of important results were achieved in the course of this project. Among them were the development of a miniaturized GC subsystem, with a unique desorber-injector, fully temperature feedback controlled oven with powered cooling for rapid reset to ambient conditions, a unique combination inlet system to the MS that provides for both membrane sampling and direct capillary column sample transfer, a compact and ruggedized alignment configuration for the MS, an improved ion source design for increased sensitivity, and a simple, rugged tandem MS configuration that is particularly adaptable to spacecraft use because of its low power and low vacuum pumping requirements. The potential applications of this research include use in manned spacecraft like the space station as a real-time detection and warning device for the presence of potentially harmful trace contaminants of the spacecraft atmosphere, use as an analytical device for evaluating samples collected on the Moon or a planetary surface, or even use in connection with monitoring potentially hazardous conditions that may exist in terrestrial locations such as launch pads, environmental test chambers or other sensitive areas. Commercial development of the technology

  10. Monolithic Parallel Tandem Organic Photovoltaic Cell with Transparent Carbon Nanotube Interlayer

    Science.gov (United States)

    Tanaka, S.; Mielczarek, K.; Ovalle-Robles, R.; Wang, B.; Hsu, D.; Zakhidov, A. A.

    2009-01-01

    We demonstrate an organic photovoltaic cell with a monolithic tandem structure in parallel connection. Transparent multiwalled carbon nanotube sheets are used as an interlayer anode electrode for this parallel tandem. The characteristics of front and back cells are measured independently. The short circuit current density of the parallel tandem cell is larger than the currents of each individual cell. The wavelength dependence of photocurrent for the parallel tandem cell shows the superposition spectrum of the two spectral sensitivities of the front and back cells. The monolithic three-electrode photovoltaic cell indeed operates as a parallel tandem with improved efficiency.

  11. Oak Ridge 24URC tandem accelerator

    International Nuclear Information System (INIS)

    Meigs, M.J.; Haynes, D.L.; Juras, R.C.

    1997-01-01

    This report discusses the operation of the Holifield Radioactive Ion Beam Facility (HRIBF) which was dedicated on December 12, 1996, with a formal ceremony followed by a reception and tour. This dedication marked the culmination of the reconfiguration, started in the middle of 1992, and the beginning of full-time operation as an international user facility. Although construction and commissioning are finished, development continues on ion sources and better methods to produce new and more intense radioactive ion beams (RIBs). The first RIB experiment, Coulomb excitation of 69 As, was completed on June 6, 1997. During the time period from June 1-6, 69 As and 67 Ga were provided for seventy-six hours with a maximum of 1.5 x 10 6 particles/sec at the experimental station. Four μA of primary beam, 42 MeV protons from the Oak Ridge Isochronous Cyclotron (ORIC), was on the 70 Ge target to produce this maximum beam. The experimenter was not set up to use this much beam, so most of the run was done at reduced levels. A second RIB experiment, again using 69 As beam, was attempted on 9/9/97. Although a beam of about 10 5 particles/second was successfully tuned to the Recoil Mass Spectrometer, the intensity produced by the RIB injector source was inadequate to complete the experiment

  12. The elastic free energy of a tandem modular protein under force.

    Science.gov (United States)

    Valle-Orero, Jessica; Eckels, Edward C; Stirnemann, Guillaume; Popa, Ionel; Berkovich, Ronen; Fernandez, Julio M

    2015-05-01

    Recent studies have provided a theoretical framework for including entropic elasticity in the free energy landscape of proteins under mechanical force. Accounting for entropic elasticity using polymer physics models has helped explain the hopping behavior seen in single molecule experiments in the low force regime. Here, we expand on the construction of the free energy of a single protein domain under force proposed by Berkovich et al. to provide a free energy landscape for N tandem domains along a continuous polypeptide. Calculation of the free energy of individual domains followed by their concatenation provides a continuous free energy landscape whose curvature is dominated by the worm-like chain at forces below 20 pN. We have validated our free energy model using Brownian dynamics and reproduce key features of protein folding. This free energy model can predict the effects of changes in the elastic properties of a multidomain protein as a consequence of biological modifications such as phosphorylation or the formation of disulfide bonds. This work lays the foundations for the modeling of tissue elasticity, which is largely determined by the properties of tandem polyproteins. Copyright © 2015. Published by Elsevier Inc.

  13. Fast quantitative detection of cocaine in beverages using nanoextractive electrospray ionization tandem mass spectrometry.

    Science.gov (United States)

    Hu, Bin; Peng, Xuejiao; Yang, Shuiping; Gu, Haiwei; Chen, Huanwen; Huan, Yanfu; Zhang, Tingting; Qiao, Xiaolin

    2010-02-01

    Without any sample pretreatment, effervescent beverage fluids were manually sprayed into the primary ion plume created by using a nanoelectrospray ionization source for direct ionization, and the analyte ions of interest were guided into an ion trap mass spectrometer for tandem mass analysis. Functional ingredients (e.g., vitamins, taurine, and caffeine, etc.) and spiked impurity (e.g., cocaine) in various beverages, such as Red Bull energy drink, Coco-cola, and Pepsi samples were rapidly identified within 1.5 s. The limit of detection was found to be 7-15 fg (S/N = 3) for cocaine in different samples using the characteristic fragment (m/z 150) observed in the MS(3) experiments. Typical relative standard deviation and recovery of this method were 6.9%-8.6% and 104%-108% for direct analysis of three actual samples, showing that nanoextractive electrospray ionization tandem mass spectrometry is a useful technique for fast screening cocaine presence in beverages. 2010. Published by Elsevier Inc.

  14. Evolution of the Argonne Tandem Linear Accelerator System (ATLAS) control system

    International Nuclear Information System (INIS)

    Power, M.; Munson, F.

    2012-01-01

    Given that the Argonne Tandem Linear Accelerator System (ATLAS) recently celebrated its 25. anniversary, this paper will explore the past, present, and future of the ATLAS Control System, and how it has evolved along with the accelerator and control system technology. ATLAS as we know it today, originated with a Tandem Van de Graff in the sixties. With the addition of the Booster section in the late seventies, came the first computerized control. ATLAS itself was placed into service on June 25, 1985, and was the world's first superconducting linear accelerator for ions. Since its dedication as a National User Facility, more than a thousand experiments by more than 2,000 users worldwide, have taken advantage of the unique capabilities it provides. Today, ATLAS continues to be a user facility for physicists who study the particles that form the heart of atoms. Its most recent addition, CARIBU (Californium Rare Isotope Breeder Upgrade), creates special beams that feed into ATLAS. ATLAS is similar to a living organism, changing and responding to new technological challenges and research needs. As it continues to evolve, so does the control system: from the original days using a DEC PDP-11/34 computer and two CAMAC crates, to a DEC Alpha computer running Vsystem software and more than twenty CAMAC crates, to distributed computers and VME systems. Future upgrades are also in the planning stages that will continue to evolve the control system. (authors)

  15. MS2Analyzer: A Software for Small Molecule Substructure Annotations from Accurate Tandem Mass Spectra

    Science.gov (United States)

    2015-01-01

    Systematic analysis and interpretation of the large number of tandem mass spectra (MS/MS) obtained in metabolomics experiments is a bottleneck in discovery-driven research. MS/MS mass spectral libraries are small compared to all known small molecule structures and are often not freely available. MS2Analyzer was therefore developed to enable user-defined searches of thousands of spectra for mass spectral features such as neutral losses, m/z differences, and product and precursor ions from MS/MS spectra in MSP/MGF files. The software is freely available at http://fiehnlab.ucdavis.edu/projects/MS2Analyzer/. As the reference query set, 147 literature-reported neutral losses and their corresponding substructures were collected. This set was tested for accuracy of linking neutral loss analysis to substructure annotations using 19 329 accurate mass tandem mass spectra of structurally known compounds from the NIST11 MS/MS library. Validation studies showed that 92.1 ± 6.4% of 13 typical neutral losses such as acetylations, cysteine conjugates, or glycosylations are correct annotating the associated substructures, while the absence of mass spectra features does not necessarily imply the absence of such substructures. Use of this tool has been successfully demonstrated for complex lipids in microalgae. PMID:25263576

  16. Potential formation and confinement in high density plasma on the GAMMA 10 tandem mirror

    International Nuclear Information System (INIS)

    Yatsu, K.

    2002-01-01

    After the attainment of doubling of the density due to the potential confinement, GAMMA 10 experiments have been directed to realization of a high density plasma and also to study dependence of the confining potential and confinement time on the plasma density. These problems are important to understand the physics of potential formation in tandem mirrors and also for the development of a tandem mirror reactor. We reported high density plasma production by using an ion cyclotron range of frequency heating at a high harmonic frequency in the last IAEA Conference. However, the diamagnetic signal of the high density plasma decreased when electron cyclotron resonance heating (ECRH) was applied due to some instabilities. Recently, the high density plasma production was much improved by adjusting the spacing of the conducting plates installed in the anchor transition regions, which enabled us to produce a high density plasma without degradation of the diamagnetic signal with ECRH and also to study the density dependence. In this paper we report production of a high density plasma and dependence of the confining potential and the confinement time on the density. (author)

  17. In situ TEM-tandem/implanter interface facility in Wuhan University for investigation of radiation effects

    International Nuclear Information System (INIS)

    Guo Liping; Li Ming; Liu Chuansheng; Song Bo; Ye Mingsheng; Fan Xiangjun; Fu Dejun

    2007-01-01

    Transmission electron microscope (TEM) interfaced to one or more ion implanters and/or accelerators, i.e. in situ TEM, provides effective tools to observe microstructural changes of studied samples during the ion irradiation. Evolution of both radiation damages and irradiation-induced nano-sized microstructures can be investigated with this technique, much more convenient than conventional ex situ techniques. In situ TEM technique has been widely applied in various fields, especially in the study of radiation damages of structural materials of fission and fusion nuclear reactors, and in evaluation and qualification of radioactive waste forms. Nowadays there are more than a dozen such facilities located in Japan, France, and the United States. Recently, we have constructed the first TEM-Tandem/Implanter interface facility of China in Wuhan University. A modified Hitachi H800 TEM was interfaced to a 200 kV ion implanter and a 2 x 1.7 MV tandem accelerator. Effective steps were taken to isolate the TEM from mechanical vibration from the ion beam line, and no obvious wobbling of the TEM image was observed during the ion implantation. The amorphization process of Si crystal irradiated by 115 keV N + ion beam was observed in the primary experiments, demonstrating that this interface facility is capable of in situ study of radiation effects. An online low energy gaseous ion source which may provide 1-20 keV H + and He + is under construction. (authors)

  18. On the startup and shutdown of a tandem mirror reactor

    International Nuclear Information System (INIS)

    Chang, F.R.; DeCanio, F.T.; Fisher, J.L.; Madden, P.A.

    1979-01-01

    The startup and shutdown of a fusion reactor must be performed in such a way that the plasma remains MHD stable. In a tandem mirror the stability depends on a sufficiently high pressure ratio between the plugs and the central cell, of the order of 100. Control of the neutral beam input to the plugs by means of active feedback has been investigated to achieve an acceptable pressure ratio throughout the entire startup/shutdown transient. An algorithm to control the beam input power has been developed. The control law was subsequently tested in a tandem mirror simulation code. This paper describes the basic models incorporated in the simulation, as well as the derivation of the control algorithm. The simulation results are presented and the practicality of implementing the algorithm is discussed. 4 refs

  19. Single P-N junction tandem photovoltaic device

    Science.gov (United States)

    Walukiewicz, Wladyslaw [Kensington, CA; Ager, III, Joel W.; Yu, Kin Man [Lafayette, CA

    2011-10-18

    A single P-N junction solar cell is provided having two depletion regions for charge separation while allowing the electrons and holes to recombine such that the voltages associated with both depletion regions of the solar cell will add together. The single p-n junction solar cell includes an alloy of either InGaN or InAlN formed on one side of the P-N junction with Si formed on the other side in order to produce characteristics of a two junction (2J) tandem solar cell through only a single P-N junction. A single P-N junction solar cell having tandem solar cell characteristics will achieve power conversion efficiencies exceeding 30%.

  20. Magnet system for a thermal barrier Tandem Mirror Reactor

    International Nuclear Information System (INIS)

    Kim, N.S.; Conn, R.W.

    1981-01-01

    The magnet system for a thermal barrier D-D tandem mirror reactor has been studied as part of the UCLA tandem mirror reactor design study SATYR. Three main considerations in designing the SATYR magnet system are to obtain the desired field strength variation throughout the system, to have proper space for plasma and neutron shielding, and to satisfy the MHD stability to achieve maximum central cell /beta/. Due to the importance and the complexity, the 'internal' field reversal magnet is the main concern in the entire magnet system for SATYR. Two different magnet designs, a non-uniform current density solenoid and a higher-order solenoid, are discussed. Coil levitation for the internal field reversal magnet has been analyzed

  1. Graphene based integrated tandem supercapacitors fabricated directly on separators

    KAUST Repository

    Chen, Wei

    2015-04-09

    It is of great importance to fabricate integrated supercapacitors with extended operation voltages as high energy density storage devices. In this work, we develop a novel direct electrode deposition on separator (DEDS) process to fabricate graphene based integrated tandem supercapacitors for the first time. The DEDS process generates compact graphene-polyaniline electrodes directly on the separators to form integrated supercapacitors. The integrated graphene-polyaniline tandem supercapacitors demonstrate ultrahigh volumetric energy density of 52.5 Wh L^(−1) at power density of 6037 W L^(−1) and excellent gravimetric energy density of 26.1 Wh kg^(−1) at power density of 3002 W kg^(−1) with outstanding electrochemical stability for over 10000 cycles. This study show great promises for the future development of integrated energy storage devices.

  2. Major maintenance of the Munich MP-tandem

    International Nuclear Information System (INIS)

    Muenzer, H.; Carli, W.; Hartung, P.; Jakob, H.; Nocker, H.; Rohrer, L.; Schnitter, H.; Assmann, W.; Maier, H.J.; Machlitt, N.; Steffens, H.

    1988-01-01

    Several measures have been taken to restore the voltage performance of the Munich tandem. 1. All accelerator tubes were reconditioned by sandblasting, new electrodes and diaphragms were inserted and preassembled groups of tubes were baked in high vacuum. 2. All other vacuum components were cleaned, baked in high vacuum and partly pressure leak tested outside the tandem. 3. High voltage tests were performed with tubes. Without portico voltages up to 16 MV were obtained, with portico up to 17.5 MV. 4. Some modifications (e.g. infrared light links) were introduced. The shutdown lasted 6 months. In March 1987 beam operation was resumed at moderate terminal voltages, interrupted by intervals of soft conditioning. (orig.)

  3. Use of molecular ion beams from a tandem accelerator

    International Nuclear Information System (INIS)

    Faibis, A.; Goldring, G.; Hass, M.; Kaim, R.; Plesser, I.; Vager, Z.

    1981-01-01

    A large variety of positive molecular ion beams can be produced by gaseous charge exchange in the terminal of a tandem accelerator. After acceleration the molecules are usually dissociated by passage through a thin foil. Measurements of the break-up products provide a way to study both the structure of incident ions and the effects of electronic potentials on the internuclear interaction inside the foil. Beam intensities of a few picoamperes are quite adequate for these measurements, and the relatively high energy obtained by use of a tandem accelerator has the advantage of minimizing multiple scattering effects in the foil. The main difficulty in using the molecular beams lies in the large magnetic rigidity of singly-charged heavy molecular ions

  4. Radiocarbon dating with the Chalk River MP Tandem accelerator

    International Nuclear Information System (INIS)

    Ball, G.C.; Andrews, H.R.; Brown, R.M.; Burn, N.; Davies, W.G.; Imahori, Y.; Milton, J.C.D.

    1981-01-01

    During the past three years an automated radiocarbon dating system based on the MP Tandem accelerator has been developed for the analysis of 14 C in groundwater samples from the nuclear waste disposal research program and other small samples of scientific interest. At the present time 14 C/ 12 C ratio measurements can be determined with an accuracy of about 5% and the system background levels (approx. 35000 to 45000 years) are totally determined by sample and/or ion source contamination. Our goal has been to develop a dedicated reliable system for routine analysis that will produce accurate results with a minimum expenditure of human resources and accelerator beam time. Improvements required to operate the tandem accelerator as a quantitative tool have also benefited the rest of the experimental nuclear physics program. The early evolution of the dating facility was described previously. This paper is a brief report of the current status at Chalk River

  5. Rhodium-Biphephos-Catalyzed Tandem Isomerization–Hydroformylation of Oleonitrile

    Directory of Open Access Journals (Sweden)

    Lucas Le Goanvic

    2018-01-01

    Full Text Available Tandem isomerization–hydroformylation of oleonitrile (an 18-carbon nitrile with a remote internal (9-C=C bond has been studied using Rh-bisphosphite catalyst systems, targeting formation of the linear aldehyde. The best compromise between regioselectivity (l/b = 58:42 and chemoselectivity (60% was obtained at 120 °C and 10 bar CO/H2 (1:1 with a catalyst based on Biphephos at a 0.5 mol % catalyst load and a low ligand excess (2 equiv. versus Rh. These values stand among the better reported ones for the tandem isomerization–hydroformylation of long chain olefins with a single-component catalyst system.

  6. Accelerator tube vacuum conditions in the NSF tandem

    International Nuclear Information System (INIS)

    Groome, A.E.

    1979-08-01

    The Nuclear Structure Facility currently under construction at the Daresbury Laboratory contains a 30 MV tandem Van de Graaff accelerator with a modular design of accelerator tube. The vacuum system requirements are specified to limit beam loss due to charge-state-changing collisions in the residual gas. This report gives an assessment of some of the parameters affecting the vacuum pressure in an operational machine. Measurements are made of the vacuum conductance and outgassing rate of accelerator tube modules. An assessment is made of the effects of temperature rise, beam mis-steering and the presence of suppression magnets on the ultimate vacuum obtainable. Predictions are made of the pressure profile throughout the machine and consideration is given to operational problems such as tube conditioning and temporary loss of pumping. A schematic diagram of the tandem and its vacuum system is shown. (author)

  7. MINIMARS: An attractive small tandem mirror fusion reactor

    International Nuclear Information System (INIS)

    Perkins, L.J.; Logan, B.G.; Doggett, J.N.; Devoto, R.S.

    1986-01-01

    Through the innovative design of a novel end plug scheme employing octopole MHD stabilization, the authors present the conceptual design of ''MINIMARS'', a small commercial fusion reactor based on the tandem mirror principle. The current baseline for MINIMARS has a net electric output of 600 MWe and they have configured the design for short construction times, factory-built modules, inherently safe blanket systems, and multiplexing in station sizes of ≅ 600-2400 MWe. They demonstrate that the compact octopole end cell provides a number of advantages over the more conventional quadrupole (yin-yang) end cell encountered in the MARS tandem mirror reactor study, and enables ignition to be achieved with much shorter central cell lengths. Accordingly, being economic in small sizes, MINIMARS provides an attractive alternative to the more conventional larger conceptual fusion reactors encountered to date, and would contribute significantly to the lowering of utility financial risk in a developing fusion economy

  8. Interpretation of Tandem Mass Spectrometry (MSMS) Spectra for Peptide Analysis

    DEFF Research Database (Denmark)

    Hjernø, Karin; Højrup, Peter

    2015-01-01

    The aim of this chapter is to give a short introduction to peptide analysis by mass spectrometry (MS) and interpretation of fragment mass spectra. Through examples and guidelines we demonstrate how to understand and validate search results and how to perform de novo sequencing based on the often...... very complex fragmentation pattern obtained by tandem mass spectrometry (also referred to as MSMS). The focus is on simple rules for interpretation of MSMS spectra of tryptic as well as non-tryptic peptides....

  9. The Friction of Vehicle Brake Tandem Master Cylinder

    International Nuclear Information System (INIS)

    Kao, M J; Chang, H; Tsung, T T; Lin, H M

    2006-01-01

    The behaviour of an elastomeric seal for vehicle brake Tandem master cylinder is measured and analyzed in temperature and brake fluids changed. Working conditions are simulated for different piston rod velocity and cylinder supply pressure, in temperature rising, brakefluid boundary and Nanoaluminum oxide brakefluid oxide brakefluid lubrication. The result shows that Nanoaluminum oxide brakefluid with its ball shape can highly reduce friction coefficient to avoid seal excessive wear and reduce slick slip in brake applications

  10. Accelerator mass spectrometry at the Rossendorf 5 MV tandem accelerator

    International Nuclear Information System (INIS)

    Friedrich, M.; Buerger, W.; Curian, H.; Hartmann, B.; Hentschel, E.; Matthes, H.; Probst, W.; Seidel, M.; Turuc, S.; Hebert, D.; Rothe, T.; Stolz, W.

    1992-01-01

    The Rossendorf electrostatic accelerators (5 MV tandem accelerator and single ended 2 MV van de Graaff accelerator) are already used for ion beam analysis. The existing methods (RBS, PIXE, ERDA, NRA, nuclear microprobe and external beam) will be completed by introduction of Accelerator Mass Spectrometry (AMS). A short description of the Rossendorf AMS system is given and first experimental results are presented. (R.P.) 4 refs.; 6 figs

  11. Charge exchange cooling in the tandem mirror plasma confinement apparatus

    Science.gov (United States)

    Logan, B. Grant

    1978-01-01

    Method and apparatus for cooling a plasma of warm charged species confined in the center mirror cell of the tandem mirror apparatus by injecting cold neutral species of the plasma into at least one mirroring region of the center mirror cell, the cooling due to the loss of warm charged species through charge exchange with the cold neutral species with resulting diffusion of the warm neutral species out of the plasma.

  12. Charge exchange cooling in the tandem mirror plasma confinement apparatus

    International Nuclear Information System (INIS)

    Logan, B.G.

    1978-01-01

    A method and apparatus are described for cooling a plasma confined in the center mirror cell of the tandem mirror apparatus by injecting cold neutral species of the plasma into at least one mirroring region of the center mirror cell. The cooling is due to the loss of warm charged species through charge exchange with the cold neutral species with resulting diffusion of the warm neutral species out of the plasma

  13. Tandem planet formation for solar system-like planetary systems

    Directory of Open Access Journals (Sweden)

    Yusuke Imaeda

    2017-03-01

    Full Text Available We present a new united theory of planet formation, which includes magneto-rotational instability (MRI and porous aggregation of solid particles in a consistent way. We show that the “tandem planet formation” regime is likely to result in solar system-like planetary systems. In the tandem planet formation regime, planetesimals form at two distinct sites: the outer and inner edges of the MRI suppressed region. The former is likely to be the source of the outer gas giants, and the latter is the source for the inner volatile-free rocky planets. Our study spans disks with a various range of accretion rates, and we find that tandem planet formation can occur for M˙=10−7.3-10−6.9M⊙yr−1. The rocky planets form between 0.4–2 AU, while the icy planets form between 6–30 AU; no planets form in 2–6 AU region for any accretion rate. This is consistent with the gap in the solid component distribution in the solar system, which has only a relatively small Mars and a very small amount of material in the main asteroid belt from 2–6 AU. The tandem regime is consistent with the idea that the Earth was initially formed as a completely volatile-free planet. Water and other volatile elements came later through the accretion of icy material by occasional inward scattering from the outer regions. Reactions between reductive minerals, such as schreibersite (Fe3P, and water are essential to supply energy and nutrients for primitive life on Earth.

  14. Tamiz metabólico neonatal por espectrometría de masas en tándem: dos años de experiencia en Nuevo León, México Expand newborn screening using tandem mass spectrometry: two years' experience in Nuevo León, Mexico

    Directory of Open Access Journals (Sweden)

    María del Rosario Torres-Sepúlveda

    2008-06-01

    Full Text Available OBJETIVO: Instituir un programa estatal de tamizaje neonatal ampliado para identificar errores innatos del metabolismo y determinar su prevalencia en la población de recién nacidos del estado de Nuevo León. MATERIAL Y MÉTODOS: Entre marzo de 2002 y febrero de 2004 se incluyeron neonatos consecutivos nacidos en hospitales públicos del estado. Se colectaron muestras de sangre en papel filtro entre las 24 y 48 horas de vida y se las sometió a tamiz metabólico mediante espectrometría de masas en tándem. RESULTADOS: Se analizaron 42 264 primeras muestras y se detectaron siete casos, uno de cada padecimiento: homocistinuria, fenilcetonuria, citrulinemia, tirosinemia/transitoria, deficiencia de 3-metilcrotonil-CoA carboxilasa, deficiencia de 3-hidroxi-3-metilglutaril-CoA liasa y galactosemia típica. CONCLUSIONES: La incidencia acumulada de defectos metabólicos en la población fue de 1:5 000 con 0.22% de casos falso-positivos. El programa permitió identificar y tratar con oportunidad los trastornos metabólicos al nacimiento con una efectiva prevención secundaria del retraso mental.OBJECTIVE: To initiate a statewide expanded metabolic screening program in neonates with the purpose of identifying the most common inborn errors of metabolism. MATERIAL AND METHODS: From March 2002 through February 2004, a blood sample was obtained between 24 and 48 hours after delivery from every consecutive child born in public hospitals in Nuevo León. It was spotted on filter paper and analyzed by tandem mass spectrometry for expanded metabolic screening. RESULTS: A total of 42 264 samples were analyzed. Were obtained seven positive results, one for each disorder: homocystinuria, hyperphenylalaninemia, citrulinemia, transient tyrosinemia, 3-methylcrotonyl CoA carboxylase deficiency, 3-hydroxy-3-methylglutaryl CoA deficiency, and classic galactosemia. CONCLUSIONS: The estimated incidence of inborn errors of metabolism is 1:5 000, with a false positive rate

  15. Solution processed organic bulk heterojunction tandem solar cells

    Energy Technology Data Exchange (ETDEWEB)

    Albrecht, Steve; Neher, Dieter [Soft Matter Physics, University of Potsdam, D-14476 Potsdam (Germany)

    2011-07-01

    One of the critical issues regarding the preparation of organic tandem solar cells from solution is the central recombination contact. This contact should be highly transparent and conductive to provide high recombination currents. Moreover it should protect the 1st subcell from the solution processing of the 2nd subcell. Here, we present a systematic study of various recombination contacts in organic bulk heterojunction tandem solar cells made from blends of different polymers with PCBM. We compare solution processed recombination contacts fabricated from metal-oxides (TiO{sub 2} and ZnO) and PEDOT:PSS with evaporated recombination contacts made from thin metal layers and molybdenum-oxide. The solar cell characteristics as well as the morphology of the contacts measured by AFM and SEM are illustrated. To compare the electrical properties of the varying contacts we show measurements on single carrier devices for different contact-structures. Alongside we present the results of optical modeling of the subcells and the complete tandem device and relate these results to experimental absorption and reflection spectra of the same structures. Based on these studies, layer thicknesses were adjusted for optimum current matching and device performance.

  16. Preliminary design of a Tandem-Mirror-Next-Step facility

    International Nuclear Information System (INIS)

    Damm, C.C.; Doggett, J.N.; Bulmer, R.H.

    1980-01-01

    The Tandem-Mirror-Next-Step (TMNS) facility is designed to demonstrate the engineering feasibility of a tandem-mirror reactor. The facility is based on a deuterium-tritium (D-T) burning, tandem-mirror device with a fusion power output of 245 MW. The fusion power density in the central cell is 2.1 MW/m 3 , with a resultant neutron wall loading of 0.5 MW/m 2 . Overall machine length is 116 m, and the effective central-cell length is 50.9 m. The magnet system includes end cells with yin-yang magnets to provide magnetohydrodynamic (MHD) stability and thermal-barrier cells to help achieve a plasma Q of 4.7 (where Q = fusion power/injected power). Neutral beams at energies up to 200 keV are used for plasma heating, fueling, and barrier pumping. Electron cyclotron resonant heating at 50 and 100 GHz is used to control the electron temperature in the barriers. Based on the resulting engineering design, the overall cost of the facility is estimated to be just under $1 billion. Unresolved physics issues include central-cell β-limits against MHD ballooning modes (the assumed reference value of β exceeds the current theory-derived limit), and the removal of thermalized α-particles from the plasma

  17. Photonic intermediate layer for silicon tandem solar cells

    Energy Technology Data Exchange (ETDEWEB)

    Bielawny, Andreas; Miclea, Paul-Tiberiu; Wehrspohn, Ralf [Martin-Luther Universitaet Halle-Wittenberg (Germany). Inst. fuer Physik, Mikro-MD; Lee, Seuong-Mo; Knez, Mato [Max-Planck-Inst. fuer Mikrostrukturphysik, Halle (Germany); Carius, Reinhard [Forschungszentrum Juelich (DE). Inst. fuer Photovoltaik (IEF-5); Lisca, Marian; Rockstuhl, Carsten; Lederer, Falk [Universitaet Jena (Germany). Dept. Physik

    2008-07-01

    The concept of incorporation of a 3D photonic crystal as diffractive spectral filter within a-Si/mc-Si tandem solar cells has been investigated as a promising application. Our intermediate reflective filter enhances the pathway of spectrally selected light within an amorphous silicon top cell in its spectral region of low absorption. From our previous work, we expect a significant improvement of the tandem's efficiency of about 1.2%(absolute). This increases efficiency for a typical silicon tandem cell from 11.2% to 12.4%, as a result of the optical current-matching of the two junctions. Our wavelength-selective optical element is a 3D-structured optical thin-film - prepared by self-organized artificial opal templates and finalized with atomic layer deposition techniques. The resulting samples are highly periodical thin-film inverted opals made of zinc-oxide. We compare recent experimental data on the optical properties with our simulations and photonic bandstructure calculations.

  18. Evolution of the Fusion Power Demonstration tandem mirror reactor configuration

    International Nuclear Information System (INIS)

    O'Toole, J.A.; Lousteau, D.C.

    1985-01-01

    This paper gives a presentation of the evolution of configurations proposed for tandem mirror Fusion Power Demonstration (FPD) machines. The FPD study was undertaken to scope the mission as well as the technical and design requirements of the next tandem mirror device. Three configurations, entitled FPD I, II, and III were studied. During this process new systems were conceived and integrated into the design, resulting in a significantly changed overall machine configuration. The machine can be divided into two areas. A new center cell configuration, minimizing magnetic field ripple and thus maximizing center cell fusion power, features a semicontinuous solenoid. A new end cell has evolved which maintains the required thermal barrier in a significantly reduced axial length. The reduced end cell effective length leads to a shorter central cell length being required to obtain minimum ignition conditions. Introduced is the concept of an electron mantle stabilized octopole arrangement. The engineering features of the new end cell and maintenance concepts developed are influenced to a great extent by the octopole-based design. The new ideas introduced during the FPD study have brought forth a new perspective of the size, design, and maintenance of tandem mirror reactors, making them more attractive as commercial power sources

  19. Oak Ridge 25URC tandem accelerator 1994 SNEAP lab report

    International Nuclear Information System (INIS)

    Alton, G.D.; Dinehart, M.R.; Dowling, D.T.

    1994-01-01

    The 25URC tandem accelerator is still in shut-down mode until the facility is reconfigured to produce radioactive ion beams (RIBs). Again, the authors have operated approximately 200 hours for ion implantation studies in support of RIB development. Operation of the accelerator has been generally very reliable with most problems being associated with power supplies and components located outside the accelerator. The major operational problem this year was the development of internal shorts in the coils of the energy-analyzing magnet which caused beam instability. The major development activity for the tandem accelerator was the replacement of the corona-point voltage-grading system with resistors. Several milestones for the RIB project have been met since SNEAP 1993. The high-voltage platforms have been built and tested at the required 300 kV. Most equipment has been installed on the platforms so that the first beam can be developed using the Mark I target-ion source. This ion source was characterized on the ion source test facility before moving it to the platform. The second-stage mass-separator magnets have been specified and the contract has been awarded to Sigma Phi. The final optics design for the beam line from the second-stage separator to the tandem accelerator is being completed and equipment and controls are being procured

  20. Tandem collimators for the JET tangential gamma-ray spectrometer

    International Nuclear Information System (INIS)

    Soare, Sorin; Balshaw, Nick; Blanchard, Patrick; Craciunescu, Teddy; Croft, David; Curuia, Marian; Edlington, Trevor; Kiptily, Vasily; Murari, Andrea; Prior, Phil; Sanders, Steven; Syme, Brian; Zoita, Vasile

    2011-01-01

    The tangential gamma-ray spectrometer (TGRS) of the JET tokamak fusion facility is an important diagnostics for investigating the fast particle evolution. A well defined field of view for the TGRS diagnostics is essential for its proper operation and this is to be determined by a rather complex system of collimators and shields both for the neutron and gamma radiations. A conceptual design for this system has been carried out with the main design target set to maximize the signal-to-background ratio at the spectrometer detector, the ratio being defined in terms of the plasma emitted gamma radiation and the gamma-ray background. As a first phase of the TGRS diagnostics upgrade a set of two tandem collimators has been designed with the aim of determining a quasi-tangential field of view through JET tokamak plasmas. A modular design of the tandem system has been developed in order to allow for the construction of different configurations for deuterium and deuterium-tritium discharges. The internal structure of the collimators consists of nuclear grade lead and high density polyethylene slabs arranged in an optimized pattern. The performance of a simplified geometry of the tandem collimator configuration has been evaluated by neutron and photon transport calculations and the numerical results show that the design parameters can be attained.

  1. Annotating and Interpreting Linear and Cyclic Peptide Tandem Mass Spectra.

    Science.gov (United States)

    Niedermeyer, Timo Horst Johannes

    2016-01-01

    Nonribosomal peptides often possess pronounced bioactivity, and thus, they are often interesting hit compounds in natural product-based drug discovery programs. Their mass spectrometric characterization is difficult due to the predominant occurrence of non-proteinogenic monomers and, especially in the case of cyclic peptides, the complex fragmentation patterns observed. This makes nonribosomal peptide tandem mass spectra annotation challenging and time-consuming. To meet this challenge, software tools for this task have been developed. In this chapter, the workflow for using the software mMass for the annotation of experimentally obtained peptide tandem mass spectra is described. mMass is freely available (http://www.mmass.org), open-source, and the most advanced and user-friendly software tool for this purpose. The software enables the analyst to concisely annotate and interpret tandem mass spectra of linear and cyclic peptides. Thus, it is highly useful for accelerating the structure confirmation and elucidation of cyclic as well as linear peptides and depsipeptides.

  2. Polarized ionic source of the tandem accelerator in Kyoto University

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, Masanobu; Kuwamoto, Shuichi; Takahashi, Seiji [Kyoto Univ. (Japan). Dept. of Physics] [and others

    1997-02-01

    A polarized ion source developed under the National Laboratory of High Energy Physics was transferred to the tandem accelerator in Kyoto University at beginning of 1993 to constitute a displacement of incidence into the accelerator. This was an atomic beam type polarized ion source, which is designed to adopt permanent magnets for 6 poles magnet to polarize the electron, to take out atomic nucleus on a shape of positive ion by ECR ionizer after transferring its polarization through transition using radio frequency (RFT), to make it negative ion by charge conversion using alkaline metal vapor, and to put it into the tandem accelerator. Test of the positive ion was finished at the National Laboratory of High Energy Physics, and test in Kyoto University was required after its negative ionization. As the estimated cost was unsufficient and entrance into the ion source facility in the tandem accelerator building was limited in Kyoto University, step of development was slow. Here is reported on present state of the ion source which is now operating stably. (G.K.)

  3. Forensic analysis of printing inks using tandem Laser Induced Breakdown Spectroscopy and Laser Ablation Inductively Coupled Plasma Mass Spectrometry

    International Nuclear Information System (INIS)

    Subedi, Kiran; Trejos, Tatiana; Almirall, José

    2015-01-01

    Elemental analysis, using either LA-ICP-MS or LIBS, can be used for the chemical characterization of materials of forensic interest to discriminate between source materials originating from different sources and also for the association of materials known to originate from the same source. In this study, a tandem LIBS/LA-ICP-MS system that combines the benefits of both LIBS and LA-ICP-MS was evaluated for the characterization of samples of printing inks (toners, inkjets, intaglio and offset.). The performance of both laser sampling methods is presented. A subset of 9 black laser toners, 10 colored (CMYK) inkjet samples, 12 colored (CMYK) offset samples and 12 intaglio inks originating from different manufacturing sources were analyzed to evaluate the discrimination capability of the tandem method. These samples were selected because they presented a very similar elemental profile by LA-ICP-MS. Although typical discrimination between different ink sources is found to be > 99% for a variety of inks when only LA-ICP-MS was used for the analysis, additional discrimination was achieved by combining the elemental results from the LIBS analysis to the LA-ICP-MS analysis in the tandem technique, enhancing the overall discrimination capability of the individual laser ablation methods. The LIBS measurements of the Ca, Fe, K and Si signals, in particular, improved the discrimination for this specific set of different ink samples previously shown to exhibit very similar LA-ICP-MS elemental profiles. The combination of these two techniques in a single setup resulted in better discrimination of the printing inks with two distinct fingerprint spectra, providing information from atomic/ionic emissions and isotopic composition (m/z) for each ink sample. - Highlights: • The optimization of the parameters for LA-ICP-MS and LIBS in a tandem experiment are presented. • The analytical figures of merit for the tandem experiment for data collected simultaneously, are presented. • A

  4. Forensic analysis of printing inks using tandem Laser Induced Breakdown Spectroscopy and Laser Ablation Inductively Coupled Plasma Mass Spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Subedi, Kiran, E-mail: ksube001@fiu.edu; Trejos, Tatiana, E-mail: trejost@fiu.edu; Almirall, José, E-mail: almirall@fiu.edu

    2015-01-01

    Elemental analysis, using either LA-ICP-MS or LIBS, can be used for the chemical characterization of materials of forensic interest to discriminate between source materials originating from different sources and also for the association of materials known to originate from the same source. In this study, a tandem LIBS/LA-ICP-MS system that combines the benefits of both LIBS and LA-ICP-MS was evaluated for the characterization of samples of printing inks (toners, inkjets, intaglio and offset.). The performance of both laser sampling methods is presented. A subset of 9 black laser toners, 10 colored (CMYK) inkjet samples, 12 colored (CMYK) offset samples and 12 intaglio inks originating from different manufacturing sources were analyzed to evaluate the discrimination capability of the tandem method. These samples were selected because they presented a very similar elemental profile by LA-ICP-MS. Although typical discrimination between different ink sources is found to be > 99% for a variety of inks when only LA-ICP-MS was used for the analysis, additional discrimination was achieved by combining the elemental results from the LIBS analysis to the LA-ICP-MS analysis in the tandem technique, enhancing the overall discrimination capability of the individual laser ablation methods. The LIBS measurements of the Ca, Fe, K and Si signals, in particular, improved the discrimination for this specific set of different ink samples previously shown to exhibit very similar LA-ICP-MS elemental profiles. The combination of these two techniques in a single setup resulted in better discrimination of the printing inks with two distinct fingerprint spectra, providing information from atomic/ionic emissions and isotopic composition (m/z) for each ink sample. - Highlights: • The optimization of the parameters for LA-ICP-MS and LIBS in a tandem experiment are presented. • The analytical figures of merit for the tandem experiment for data collected simultaneously, are presented. • A

  5. Present status of Kyushu University tandem accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, Hiroyuki; Marinobu, Shunpei; Makajima, Takao [Kyushu Univ., Fukuoka (Japan). Faculty of Science; and others

    1996-12-01

    The accelerator has been operated almost smoothly. The number of uncovering in the last one year was several times for exchanging C-foils. The time of operation in 1995 was about 2500 hours. The nuclides of the beams used in the last one year are shown, and the nuclide that the nuclear spectroscopy group used changed from Si and S to B and others. The coil which has been used for 20 years was renewed in 1995, due to current leak and unstable magnetic field. For purifying SF6 gas, when it is filled in a tank, it is passed through a molecular sieve. The molecular sieve is regenerated by heating the tower above 100 deg C while vacuumizing for removing absorbed moisture. Vacuum leak occurred in this molecular sieve tower due to thermal history and humidity for more than 10 years. The electromagnet of QQDDQQ was installed anew to the recoil particle analyzer. For analyzing {sup 36}Cl the time division operation with {sup 35}Cl and {sup 37}C1 was carried out, and the first test was finished. Helium negative ions were taken out from the polarized ion source, and used for experiment. The intensity of the negative ions was same as that of polarized beam. The development of BIGT was carried out. (K.I.)

  6. Phaedrus tandem mirror. Status report, Spring 1983

    International Nuclear Information System (INIS)

    1983-01-01

    During the spring of 1983, the Phaedrus group undertook a major up to air to improve diagnostic capabilities, modify RF antennas and clean up the inner vacuum surfaces of accumulated getter material. This time was also used to analyze more thoroughly our present data base and correlate it with relevant theoretical predictions. A neutral beam build up code has been developed to model RF central stream trapping and heating, neutral gas charge exchange losses with finite gyroradius effects, and beam aiming sensitivity. MHD stability of the central cell stand alone operation has been explained by a radial ponderomotive force which opposes the centrifugal force due to bad field line curvature. First drafts of research papers on RF trapping, electron cyclotron heating, the stand alone mode, and MHD instability studies were completed. All of these papers require more experiments to tie up loose ends but the loose ends were identified more clearly by this process. The remainder of this report will be organized by experimental area, describing in limited detail the status of current research, recent modifications to diagnostic and machine hardware and immediate future experimental objectives

  7. MAPPING GNSS RESTRICTED ENVIRONMENTS WITH A DRONE TANDEM AND INDIRECT POSITION CONTROL

    Directory of Open Access Journals (Sweden)

    E. Cledat

    2017-08-01

    Full Text Available The problem of autonomously mapping highly cluttered environments, such as urban and natural canyons, is intractable with the current UAV technology. The reason lies in the absence or unreliability of GNSS signals due to partial sky occlusion or multi-path effects. High quality carrier-phase observations are also required in efficient mapping paradigms, such as Assisted Aerial Triangulation, to achieve high ground accuracy without the need of dense networks of ground control points. In this work we consider a drone tandem in which the first drone flies outside the canyon, where GNSS constellation is ideal, visually tracks the second drone and provides an indirect position control for it. This enables both autonomous guidance and accurate mapping of GNSS restricted environments without the need of ground control points. We address the technical feasibility of this concept considering preliminary real-world experiments in comparable conditions and we perform a mapping accuracy prediction based on a simulation scenario.

  8. Generating hydrogen from sunlight and water using photovoltaic tandem cell

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2006-07-15

    Photoelectrochemical conversion of solar energy to energy in hydrogen at viable efficiency is a long-term goal needed to usher in the hydrogen economy worldwide. The twin cell technology based Tandem Cell tackles a number of challenges faced by single photoelectrochemical cell based water splitting and offers a novel way of utilising complimentary parts of the solar spectrum in two cells. The overall process results in a complete system driven by solar energy that splits water into hydrogen and oxygen. Hydrogen Solar Ltd is a UK based enterprise that is working towards commercialisation of this Tandem Cell technology. One of the main project activities involved the development and optimisation of methods for preparation of larger scale photocatalytic electrodes using reproducible low cost industrial processes, with efficiencies equal to or greater than those from small scale samples made experimentally in University laboratories. Stability is also an important issue and endurance testing was performed on some samples. Spray pyrolysis methods offer considerable promise as for preparation of metal oxide semiconductor films at low cost, reproducibly. These studies lead to optimised designs for Tandem Cells, resulting in construction of an array of 12 Tandem Cells. The findings of this array work, in particular engineering issues, were very significant. Based on this work it is intended to build another two array systems that consists of 24 Tandem Cells which will be tested for light to chemical conversion efficiency, to determine what efficiency has been achieved overall. The main conclusions resulting from this project were as follows. Overall, considerable progress was made in characterising the factors that affect photoelectrode performance efficiency but that, losses in efficiency when increasing the area of photoelectrodes was greater than expected and optimisation of efficiency at practical device scale needs more work. Based on the outcome of this work program

  9. Solution-processed parallel tandem polymer solar cells using silver nanowires as intermediate electrode.

    Science.gov (United States)

    Guo, Fei; Kubis, Peter; Li, Ning; Przybilla, Thomas; Matt, Gebhard; Stubhan, Tobias; Ameri, Tayebeh; Butz, Benjamin; Spiecker, Erdmann; Forberich, Karen; Brabec, Christoph J

    2014-12-23

    Tandem architecture is the most relevant concept to overcome the efficiency limit of single-junction photovoltaic solar cells. Series-connected tandem polymer solar cells (PSCs) have advanced rapidly during the past decade. In contrast, the development of parallel-connected tandem cells is lagging far behind due to the big challenge in establishing an efficient interlayer with high transparency and high in-plane conductivity. Here, we report all-solution fabrication of parallel tandem PSCs using silver nanowires as intermediate charge collecting electrode. Through a rational interface design, a robust interlayer is established, enabling the efficient extraction and transport of electrons from subcells. The resulting parallel tandem cells exhibit high fill factors of ∼60% and enhanced current densities which are identical to the sum of the current densities of the subcells. These results suggest that solution-processed parallel tandem configuration provides an alternative avenue toward high performance photovoltaic devices.

  10. Classroom tandem – Outlining a model for language learning and ınstruction

    Directory of Open Access Journals (Sweden)

    Katri Karjalaınen

    2013-11-01

    Full Text Available The aim of this paper is to outline classroom tandem by comparing it with informal tandem learning contexts and other language instruction methods. Classroom tandem is used for second language instruction in mixed language groups in the subjects of Finnish and Swedish as L2. Tandem learning entails that two persons with different mother tongues learn each other’s native languages in reciprocal cooperation. The students function, in turns, as a second language learner and as a model in the native language. We aim to give an overview description of the interaction in classroom tandem practice. The empirical data consists of longitudinal video recordings of meetings of one tandem dyad within a co-located Swedishmedium and Finnish-medium school. Focus in the analysis is on the language aspects the informants orient to and topicalize in their interaction. The language aspects vary depending on what classroom activities they are engaged in, text-based or oral activities.

  11. On the Relativistic Correction of Particles Trajectory in Tandem Type Electrostatic Accelerator

    OpenAIRE

    Minárik Stanislav

    2015-01-01

    A constant potential is applied to the acceleration of the ion-beam in the tandem type electrostatic accelerator. However, not just one voltage is applied, but instead a number of applications can be made in succession by means of the tandem arrangement of high voltage tubes. This number of voltage applications, which is the number of so-called "stages" of a tandem accelerator, may be two, three, or four, depending on the chosen design. Electrostatic field with approximately constant intensit...

  12. Establishment of a tandem ionization chamber system in standard mammography beams

    International Nuclear Information System (INIS)

    Silva, Jonas O. da; Caldas, L.V.E.

    2011-01-01

    A double-faced tandem ionization chamber system was developed at the Calibration Laboratory of IPEN. It has different collecting electrode materials: aluminium and graphite. The response repeatability and reproducibility and the energy dependence test of this tandem ionization chamber were evaluated. The chamber response stability is within the ±3% limit recommended in international standards. The energy dependence test of the ionization chamber system using the tandem curve obtained, presented agreement with literature results. (author)

  13. Field Test: Results of Tandem Walk Performance Following Long-Duration Spaceflight

    Science.gov (United States)

    Rosenberg, M. J. F.; Reschke, M. F.; Cerisano, J. M.; Kofman, I. S.; Fisher, E. A.; Gadd, N. E.; May-Phillips, T. R.; Lee, S. M. C.; Laurie, S. S.; Stenger, M. B.; hide

    2016-01-01

    BACKGROUND: Coordinated locomotion has proven to be challenging for many astronauts following long duration spaceflight. As NASA's vision for spaceflight points toward interplanetary travel, we must prepare for unassisted landings, where crewmembers may need to perform mission critical tasks within minutes of landing. Thus, it is vital to develop a knowledge base from which operational guidelines can be written that define when astronauts can be expected to safely perform certain tasks. Data obtained during the Field Test experiment (FT) will add important insight to this knowledge base. Specifically, we aim to develop a recovery timeline of functional sensorimotor performance during the first 24 hours and several days after landing. METHODS: FT is an ongoing study of 30 long-duration ISS crewmembers. Thus far, 9 have completed the full FT (5 U.S. Orbital Segment [USOS] astronauts and 4 Russian cosmonauts) and 4 more consented and launching within the next year. This is in addition to the eighteen crewmembers that participated in the pilot FT (11 USOS and 7 Russian crewmembers). The FT is conducted three times preflight and three times during the first 24 hours after landing. All crewmembers were tested in Kazakhstan in either the medical tent at the Soyuz landing site (one hour post-landing), or at the airport (four hours post-landing). The USOS crewmembers were also tested at the refueling stop (12 hours post-landing) and at the NASA Johnson Space Center (24 hours post-landing) and a final session 7 days post-landing. Crewmembers are instrumented with 9 inertial measurement unit sensors that measure acceleration and angular displacement (APDM's Emerald Sensors) and foot pressure-sensing insoles that measure force, acceleration, and center of pressure (Moticon GmbH, Munich, Germany) along with heart rate and blood pressure recording instrumentation. The FT consists of 12 tasks, but here we will focus on the most challenging task, the Tandem Walk, which was also

  14. Status of the tandem FEL project development in Israel

    International Nuclear Information System (INIS)

    Benzvi, I.; Sokolowski, J.; Jerby, E.; Chomski, D.; Ruschin, S.

    1989-01-01

    The authors report the status of a collaborative research project development aimed toward construction of an IR FEL based on the EN tandem electrostatic accelerator of the Weizmann Institute of Science. A preliminary feasibility demonstration project yielded encouraging progress in three aspects: (1) Electron gun and accelerator conversion: A 50-kV 1-A electron gun injector was designed, built, tested, and assembled on the 6-MeV tandem accelerator which was previously converted and conditioned to operate as an electron accelerator in a positively charged HV terminal configuration. Contrary to the configuration of the only electrostatic accelerator FEL demonstrated so far, the electron gun and multistage depressed collector are connected to the ground, and the wiggler is placed in the HV terminal of the straight geometry tandem accelerator. This configuration promises to provide a high current high quality e-beam. (2) Electron-beam transport: The first installation of the electron optical beam recovery system yielded transport efficiency of 80%. Substantial improvement is expected with planned electron optics modifications. An effect, highly significant for realizing long pulse (quasi-cw) FEL operation, was observed experimentally. Due to the damping effect of the accelerator column capacitance network, the voltage terminal stayed constant for milliseconds even with poor beam transport efficiency. This points to the possibility of developing a long pulse FEL which may operate at a single longitudinal mode. (3) Wiggler development: A conventional 4.4-cm period SmCo planar wiggler was acquired and evaluated using a recently constructed floating wire magnetic field measurement setup

  15. Improved Tandem Measurement Techniques for Aerosol Particle Analysis

    Science.gov (United States)

    Rawat, Vivek Kumar

    Non-spherical, chemically inhomogeneous (complex) nanoparticles are encountered in a number of natural and engineered environments, including combustion systems (which produces highly non-spherical aggregates), reactors used in gas-phase materials synthesis of doped or multicomponent materials, and in ambient air. These nanoparticles are often highly diverse in size, composition and shape, and hence require determination of property distribution functions for accurate characterization. This thesis focuses on development of tandem mobility-mass measurement techniques coupled with appropriate data inversion routines to facilitate measurement of two dimensional size-mass distribution functions while correcting for the non-idealities of the instruments. Chapter 1 provides the detailed background and motivation for the studies performed in this thesis. In chapter 2, the development of an inversion routine is described which is employed to determine two dimensional size-mass distribution functions from Differential Mobility Analyzer-Aerosol Particle Mass analyzer tandem measurements. Chapter 3 demonstrates the application of the two dimensional distribution function to compute cumulative mass distribution function and also evaluates the validity of this technique by comparing the calculated total mass concentrations to measured values for a variety of aerosols. In Chapter 4, this tandem measurement technique with the inversion routine is employed to analyze colloidal suspensions. Chapter 5 focuses on application of a transverse modulation ion mobility spectrometer coupled with a mass spectrometer to study the effect of vapor dopants on the mobility shifts of sub 2 nm peptide ion clusters. These mobility shifts are then compared to models based on vapor uptake theories. Finally, in Chapter 6, a conclusion of all the studies performed in this thesis is provided and future avenues of research are discussed.

  16. Effective Maxillary Protraction with Tandem Traction Bow Appliance

    Directory of Open Access Journals (Sweden)

    Pravin Kumar S Marure

    2014-01-01

    Full Text Available Tandem traction bow appliance (TTBA promotes patient compliance, because it is more esthetic and comfortable than extraoral appliances. TTBA should be used only in case where maxillary deficiency and normal mandible is present. Advantages of it includes good oral hygiene, early treatment of any Class III malocclusion, optimal retention, distribution of the forces for protraction to all maxillary teeth, free mandibular movement. It can be used in conjunction with fixed appliances if necessary. This paper includes two case reports. The treatment results in both the cases demonstrated significant skeletal and dental response to TTBA therapy. Skeletal change was primarily a result of anterior movement of the maxilla.

  17. Parametric design study of tandem mirror fusion reactors

    International Nuclear Information System (INIS)

    Carlson, G.A.

    1977-01-01

    The parametric design study of the tandem mirror reactor (TMR) is described. The results of this study illustrate the variation of reactor characteristics with changes in the independent design parameters, reveal the set of design parameters which minimizes the cost of the reactor, and show the sensitivity of the optimized design to physics and technological uncertainties. The total direct capital cost of an optimized 1000 MWe TMR is estimated to be $1300/kWe. The direct capital cost of a 2000 MWe plant is less than $1000/kWe

  18. Instruction manual for ORNL tandem high abundance sensitivity mass spectrometer

    International Nuclear Information System (INIS)

    Smith, D.H.; McKown, H.S.; Chrisite, W.H.; Walker, R.L.; Carter, J.A.

    1976-06-01

    This manual describes the physical characteristics of the tandem mass spectrometer built by Oak Ridge National Laboratory for the International Atomic Energy Agency. Specific requirements met include ability to run small samples, high abundance sensitivity, good precision and accuracy, and adequate sample throughput. The instrument is capable of running uranium samples as small as 10 -12 g and has an abundance sensitivity in excess of 10 6 . Precision and accuracy are enhanced by a special sweep control circuit. Sample throughput is 6 to 12 samples per day. Operating instructions are also given

  19. A tandem cross-metathesis/semipinacol rearrangement reaction.

    Science.gov (United States)

    Plummer, Christopher W; Soheili, Arash; Leighton, James L

    2012-05-18

    An efficient and (E)-selective synthesis of a 6-alkylidenebicyclo[3.2.1]octan-8-one has been developed. The key step is a tandem cross-metathesis/semipinacol rearrangement reaction, wherein the Hoveyda-Grubbs II catalyst, or more likely a derivative thereof, serves as the Lewis acid for the rearrangement. Despite the fact that both the starting alkene and the cross-metathesis product are viable rearrangement substrates, only the latter rearranges, suggesting that the Lewis acidic species is generated only after the cross-metathesis reaction is complete.

  20. Tailoring of targets for a tandem accelerator laboratory

    International Nuclear Information System (INIS)

    Sletten, G.

    1976-01-01

    The organization of a target laboratory serving the nuclear physics research at a tandem van de graaff accelerator is described. Emphasis is put on the layout of the laboratory and the mode of operation. The working force is about 40 h per week shared by two technical assistants, and they are supervised by a physicist who on the average spends about 1/3 of his time on target-related problems. Selected topics like heavy ion sputtering of actinides and the preparation of multilayer targets are described in detail. (author)

  1. Electrostatic field distributions in the Harwell Tandem accelerator

    International Nuclear Information System (INIS)

    Read, P.M.

    1981-11-01

    The electrostatic field distributions in the Harwell Tandem accelerator have been precisely calculated using the electrostatics program FINALE. The results indicate that the accelerator which presently has an upper voltage limit of 6.5 MV has the potential to operate at 8 MV. Such an upgrade could be achieved by a modification to the high voltage terminal. Replacement of the existing accelerator tubes with accelerator tubes capable of a gradient of 1.8 MV/m would also be required. The existing stack may also require replacement. The terminal modification itself would reduce the terminal to tank breakdown frequency. (author)

  2. Tandem mass spectrometry data quality assessment by self-convolution

    Directory of Open Access Journals (Sweden)

    Tham Wai

    2007-09-01

    Full Text Available Abstract Background Many algorithms have been developed for deciphering the tandem mass spectrometry (MS data sets. They can be essentially clustered into two classes. The first performs searches on theoretical mass spectrum database, while the second based itself on de novo sequencing from raw mass spectrometry data. It was noted that the quality of mass spectra affects significantly the protein identification processes in both instances. This prompted the authors to explore ways to measure the quality of MS data sets before subjecting them to the protein identification algorithms, thus allowing for more meaningful searches and increased confidence level of proteins identified. Results The proposed method measures the qualities of MS data sets based on the symmetric property of b- and y-ion peaks present in a MS spectrum. Self-convolution on MS data and its time-reversal copy was employed. Due to the symmetric nature of b-ions and y-ions peaks, the self-convolution result of a good spectrum would produce a highest mid point intensity peak. To reduce processing time, self-convolution was achieved using Fast Fourier Transform and its inverse transform, followed by the removal of the "DC" (Direct Current component and the normalisation of the data set. The quality score was defined as the ratio of the intensity at the mid point to the remaining peaks of the convolution result. The method was validated using both theoretical mass spectra, with various permutations, and several real MS data sets. The results were encouraging, revealing a high percentage of positive prediction rates for spectra with good quality scores. Conclusion We have demonstrated in this work a method for determining the quality of tandem MS data set. By pre-determining the quality of tandem MS data before subjecting them to protein identification algorithms, spurious protein predictions due to poor tandem MS data are avoided, giving scientists greater confidence in the

  3. Tandem mass spectrometry data quality assessment by self-convolution.

    Science.gov (United States)

    Choo, Keng Wah; Tham, Wai Mun

    2007-09-20

    Many algorithms have been developed for deciphering the tandem mass spectrometry (MS) data sets. They can be essentially clustered into two classes. The first performs searches on theoretical mass spectrum database, while the second based itself on de novo sequencing from raw mass spectrometry data. It was noted that the quality of mass spectra affects significantly the protein identification processes in both instances. This prompted the authors to explore ways to measure the quality of MS data sets before subjecting them to the protein identification algorithms, thus allowing for more meaningful searches and increased confidence level of proteins identified. The proposed method measures the qualities of MS data sets based on the symmetric property of b- and y-ion peaks present in a MS spectrum. Self-convolution on MS data and its time-reversal copy was employed. Due to the symmetric nature of b-ions and y-ions peaks, the self-convolution result of a good spectrum would produce a highest mid point intensity peak. To reduce processing time, self-convolution was achieved using Fast Fourier Transform and its inverse transform, followed by the removal of the "DC" (Direct Current) component and the normalisation of the data set. The quality score was defined as the ratio of the intensity at the mid point to the remaining peaks of the convolution result. The method was validated using both theoretical mass spectra, with various permutations, and several real MS data sets. The results were encouraging, revealing a high percentage of positive prediction rates for spectra with good quality scores. We have demonstrated in this work a method for determining the quality of tandem MS data set. By pre-determining the quality of tandem MS data before subjecting them to protein identification algorithms, spurious protein predictions due to poor tandem MS data are avoided, giving scientists greater confidence in the predicted results. We conclude that the algorithm performs well

  4. Distributed control system for NSC tandem-LINAC

    International Nuclear Information System (INIS)

    Ajith Kumar, B.P.; Subrahmaniam, E.T.; Singh, Kundan

    2001-01-01

    The new control system for the tandem-LINAC accelerator system at Nuclear Science Centre (NSC), runs on a network of Pentiums under the LINUX operating system. Some of the computers are interfaced to the devices of the accelerator, using CAMAC, and run a server program. On the same network there are machines providing the operator interface, by running the client program. The client computers use the x-window graphics and shaft encoder knobs interfaced to them to provide the operator interface. The system supports the monitoring and controlling of all the accelerator parameters including the beam profile monitors, from any of the clients. (author)

  5. Characterization of Disulfide-Linked Peptides Using Tandem Mass Spectrometry Coupled with Automated Data Analysis Software

    Science.gov (United States)

    Liang, Zhidan; McGuinness, Kenneth N.; Crespo, Alejandro; Zhong, Wendy

    2018-05-01

    Disulfide bond formation is critical for maintaining structure stability and function of many peptides and proteins. Mass spectrometry has become an important tool for the elucidation of molecular connectivity. However, the interpretation of the tandem mass spectral data of disulfide-linked peptides has been a major challenge due to the lack of appropriate tools. Developing proper data analysis software is essential to quickly characterize disulfide-linked peptides. A thorough and in-depth understanding of how disulfide-linked peptides fragment in mass spectrometer is a key in developing software to interpret the tandem mass spectra of these peptides. Two model peptides with inter- and intra-chain disulfide linkages were used to study fragmentation behavior in both collisional-activated dissociation (CAD) and electron-based dissociation (ExD) experiments. Fragments generated from CAD and ExD can be categorized into three major types, which result from different S-S and C-S bond cleavage patterns. DiSulFinder is a computer algorithm that was newly developed based on the fragmentation observed in these peptides. The software is vendor neutral and capable of quickly and accurately identifying a variety of fragments generated from disulfide-linked peptides. DiSulFinder identifies peptide backbone fragments with S-S and C-S bond cleavages and, more importantly, can also identify fragments with the S-S bond still intact to aid disulfide linkage determination. With the assistance of this software, more comprehensive disulfide connectivity characterization can be achieved. [Figure not available: see fulltext.

  6. Characterization of Disulfide-Linked Peptides Using Tandem Mass Spectrometry Coupled with Automated Data Analysis Software.

    Science.gov (United States)

    Liang, Zhidan; McGuinness, Kenneth N; Crespo, Alejandro; Zhong, Wendy

    2018-01-25

    Disulfide bond formation is critical for maintaining structure stability and function of many peptides and proteins. Mass spectrometry has become an important tool for the elucidation of molecular connectivity. However, the interpretation of the tandem mass spectral data of disulfide-linked peptides has been a major challenge due to the lack of appropriate tools. Developing proper data analysis software is essential to quickly characterize disulfide-linked peptides. A thorough and in-depth understanding of how disulfide-linked peptides fragment in mass spectrometer is a key in developing software to interpret the tandem mass spectra of these peptides. Two model peptides with inter- and intra-chain disulfide linkages were used to study fragmentation behavior in both collisional-activated dissociation (CAD) and electron-based dissociation (ExD) experiments. Fragments generated from CAD and ExD can be categorized into three major types, which result from different S-S and C-S bond cleavage patterns. DiSulFinder is a computer algorithm that was newly developed based on the fragmentation observed in these peptides. The software is vendor neutral and capable of quickly and accurately identifying a variety of fragments generated from disulfide-linked peptides. DiSulFinder identifies peptide backbone fragments with S-S and C-S bond cleavages and, more importantly, can also identify fragments with the S-S bond still intact to aid disulfide linkage determination. With the assistance of this software, more comprehensive disulfide connectivity characterization can be achieved. Graphical Abstract ᅟ.

  7. The Axisymmetric Tandem Mirror: A Magnetic Mirror Concept Game Changer Magnet Mirror Status Study Group

    International Nuclear Information System (INIS)

    Simonen, T.; Cohen, R.; Correll, D.; Fowler, K.; Post, D.; Berk, H.; Horton, W.; Hooper, E.B.; Fisch, N.; Hassam, A.; Baldwin, D.; Pearlstein, D.; Logan, G.; Turner, B.; Moir, R.; Molvik, A.; Ryutov, D.; Ivanov, A.A; Kesner, J.; Cohen, B.; McLean, H.; Tamano, T.; Tang, X.Z.; Imai, T.

    2008-01-01

    Experimental results, theory and innovative ideas now point with increased confidence to the possibility of a Gas Dynamic Trap (GDT) neutron source which would be on the path to an attractively simple Axisymmetric Tandem Mirror (ATM) power plant. Although magnetic mirror research was terminated in the US 20 years ago, experiments continued in Japan (Gamma 10) and Russia (GDT), with a very small US effort. This research has now yielded data, increased understanding, and generated ideas resulting in the new concepts described here. Early mirror research was carried out with circular axisymmetric magnets. These plasmas were MHD unstable due to the unfavorable magnetic curvature near the mid-plane. Then the minimum-B concept emerged in which the field line curvature was everywhere favorable and the plasma was situated in a MHD stable magnetic well (70% average beta in 2XII-B). The Ioffe-bar or baseball-coil became the standard for over 40 years. In the 1980's, driven by success with minimum-B stabilization and the control of ion cyclotron instabilities in PR6 and 2XII-B, mirrors were viewed as a potentially attractive concept with near-term advantages as a lower Q neutron source for applications such as a hybrid fission fuel factory or toxic waste burner. However there are down sides to the minimum-B geometry: coil construction is complex; restraining magnetic forces limit field strength and mirror ratios. Furthermore, the magnetic field lines have geodesic curvature which introduces resonant and neoclassical radial transport as observed in early tandem mirror experiments. So what now leads us to think that simple axisymmetric mirror plasmas can be stable? The Russian GDT experiment achieves on-axis 60% beta by peaking of the kinetic plasma pressure near the mirror throat (where the curvature is favorable) to counter-balance the average unfavorable mid-plane curvature. Then a modest augmentation of plasma pressure in the expander results in stability. The GDT

  8. The Axisymmetric Tandem Mirror: A Magnetic Mirror Concept Game Changer Magnet Mirror Status Study Group

    Energy Technology Data Exchange (ETDEWEB)

    Simonen, T; Cohen, R; Correll, D; Fowler, K; Post, D; Berk, H; Horton, W; Hooper, E B; Fisch, N; Hassam, A; Baldwin, D; Pearlstein, D; Logan, G; Turner, B; Moir, R; Molvik, A; Ryutov, D; Ivanov, A A; Kesner, J; Cohen, B; McLean, H; Tamano, T; Tang, X Z; Imai, T

    2008-10-24

    Experimental results, theory and innovative ideas now point with increased confidence to the possibility of a Gas Dynamic Trap (GDT) neutron source which would be on the path to an attractively simple Axisymmetric Tandem Mirror (ATM) power plant. Although magnetic mirror research was terminated in the US 20 years ago, experiments continued in Japan (Gamma 10) and Russia (GDT), with a very small US effort. This research has now yielded data, increased understanding, and generated ideas resulting in the new concepts described here. Early mirror research was carried out with circular axisymmetric magnets. These plasmas were MHD unstable due to the unfavorable magnetic curvature near the mid-plane. Then the minimum-B concept emerged in which the field line curvature was everywhere favorable and the plasma was situated in a MHD stable magnetic well (70% average beta in 2XII-B). The Ioffe-bar or baseball-coil became the standard for over 40 years. In the 1980's, driven by success with minimum-B stabilization and the control of ion cyclotron instabilities in PR6 and 2XII-B, mirrors were viewed as a potentially attractive concept with near-term advantages as a lower Q neutron source for applications such as a hybrid fission fuel factory or toxic waste burner. However there are down sides to the minimum-B geometry: coil construction is complex; restraining magnetic forces limit field strength and mirror ratios. Furthermore, the magnetic field lines have geodesic curvature which introduces resonant and neoclassical radial transport as observed in early tandem mirror experiments. So what now leads us to think that simple axisymmetric mirror plasmas can be stable? The Russian GDT experiment achieves on-axis 60% beta by peaking of the kinetic plasma pressure near the mirror throat (where the curvature is favorable) to counter-balance the average unfavorable mid-plane curvature. Then a modest augmentation of plasma pressure in the expander results in stability. The GDT

  9. Present status of tandem accelerator in Tsukuba University

    Energy Technology Data Exchange (ETDEWEB)

    Ishihara, Toyoyuki; Oshima, Hiroyuki; Ishii, Satoshi [Tsukuba Univ., Ibaraki (Japan). Tandem Accelerator Center; and others

    1996-12-01

    The tandem accelerator in Tsukuba University, 12UD Peletron, has continued the operation for 21 years, and the total operation time became 61,822 hours as of the end of March, 1996. In this paper, the state of operation of the tandem accelerator in 1995 and the state of use classified by experimental fields are reported. As for the improvement of peripheral equipment, the renewal of the radiation monitoring system and the new installation of the going-in and out control system for radiation control zones were carried out. In fiscal year 1995, the operation time of the accelerator was 3,966 hours, and ion acceleration time was 3,427 hours or 86%. The renewal and improvement of the accelerator system that had been begun in fiscal year 1989 was completed. Also the operation at highest accelerating voltage 12 MV was carried out for 7 hours. In March, the operation was not done because of the periodic inspection. The state of use of two ion sources for joint utilization is shown, and 20 kinds of ions were used. The state of joint utilization, the troubles and repair, and the renewal and new installation are reported. The plan of installing 1 MV TANDETRON is explained. (K.I.)

  10. {sup 36}Cl exposure dating with a 3-MV tandem

    Energy Technology Data Exchange (ETDEWEB)

    Steier, Peter, E-mail: peter.steier@univie.ac.a [VERA Laboratory, Fakultaet fuer Physik - Isotopenforschung, Universitaet Wien, Waehringer Strasse 17, A-1090 Wien (Austria); HPK H 31, Institut fuer Teilchenphysik, ETH Zuerich, Schafmattstr. 20 CH-8093 Zuerich (Switzerland); Forstner, Oliver; Golser, Robin; Kutschera, Walter; Martschini, Martin [VERA Laboratory, Fakultaet fuer Physik - Isotopenforschung, Universitaet Wien, Waehringer Strasse 17, A-1090 Wien (Austria); HPK H 31, Institut fuer Teilchenphysik, ETH Zuerich, Schafmattstr. 20 CH-8093 Zuerich (Switzerland); Merchel, Silke [CEREGE, CNRS-IRD-Universite Aix-Marseille, Europole Mediterraneen de L' Arbois, 13545 Aix-en-Provence (France); Forschungszentrum Dresden-Rossendorf, D-01314 Dresden (Germany); HPK H 31, Institut fuer Teilchenphysik, ETH Zuerich, Schafmattstr. 20 CH-8093 Zuerich (Switzerland); Orlowski, Tobias; Priller, Alfred [VERA Laboratory, Fakultaet fuer Physik - Isotopenforschung, Universitaet Wien, Waehringer Strasse 17, A-1090 Wien (Austria); HPK H 31, Institut fuer Teilchenphysik, ETH Zuerich, Schafmattstr. 20 CH-8093 Zuerich (Switzerland); Vockenhuber, Christof [Forschungszentrum Dresden-Rossendorf, D-01314 Dresden (Germany); HPK H 31, Institut fuer Teilchenphysik, ETH Zuerich, Schafmattstr. 20 CH-8093 Zuerich (Switzerland); Wallner, Anton [VERA Laboratory, Fakultaet fuer Physik - Isotopenforschung, Universitaet Wien, Waehringer Strasse 17, A-1090 Wien (Austria); HPK H 31, Institut fuer Teilchenphysik, ETH Zuerich, Schafmattstr. 20 CH-8093 Zuerich (Switzerland)

    2010-04-15

    {sup 36}Cl AMS measurements at natural isotopic concentrations have yet been performed only at tandem accelerators with 5 MV terminal voltage or beyond. We have developed a method to detect {sup 36}Cl at natural terrestrial isotopic concentrations with a 3-MV system, operated above specifications at 3.5 MV. An effective separation was obtained with an optimized split-anode ionization chamber design (adopted from the ETH/PSI Zurich AMS group), providing a suppression factor of up to 30,000 for the interfering isobar {sup 36}S. Despite the good separation, a relatively high sulfur output from the ion source ({sup 36}S{sup -}/{sup 35}Cl{sup -} approx 4 x 10{sup -10} for samples prepared from chemically pure reagents), and a possibly cross contamination resulted in a background corresponding to {sup 36}Cl/Cl approx 3 x 10{sup -14}. The method was applied to samples containing between 10{sup 5} and 10{sup 6} atoms {sup 36}Cl/g rock from sites in Italy and Iran, which were already investigated by other laboratories for surface exposure dating. The {sup 36}Cl/Cl ratios in the range from 2 x 10{sup -13} to 5 x 10{sup -12} show a generally good agreement with the previous results. These first measurements demonstrate that also 3-MV tandems, constituting the majority of dedicated AMS facilities, are capable of {sup 36}Cl exposure dating, which is presently the domain of larger facilities.

  11. A Tandem-electrostatic-quadrupole for accelerator-based BNCT

    International Nuclear Information System (INIS)

    Kreiner, A.J.; Kwan, J.W.; Burlon, A.A.; Di Paolo, H.; Henestroza, E.; Minsky, D.M.; Valda, A.A.; Debray, M.E.; Somacal, H.

    2007-01-01

    A project to develop a Tandem-electrostatic-quadrupole (TESQ) accelerator for accelerator-based boron neutron capture therapy (AB-BNCT) is described. A folded Tandem, with 1.25 MV terminal voltage, combined with an electrostatic quadrupole (ESQ) chain is being proposed. The project goal is a machine capable of delivering 30 mA of 2.5 MeV protons to be used in conjunction with a neutron production target based on the 7 Li(p, n) 7 Be reaction slightly beyond its resonance at 2.25 MeV. This machine is conceptually shown to be capable of accelerating a 30 mA proton beam to 2.5 MeV. These are the specifications needed to produce sufficiently intense and clean epithermal neutron beams, based on the 7 Li(p, n) 7 Be reaction, to perform BNCT treatment for deep-seated tumors in less than an hour. This electrostatic machine is the technologically simplest and cheapest solution for optimized AB-BNCT

  12. Kyushu University Tandem Accelerator Laboratory report, 1988-1990

    International Nuclear Information System (INIS)

    Sagara, Kenshi; Morinobu, Shunpei

    1991-03-01

    Ten years have elapsed since the first beam was obtained from the Kyushu University tandem accelerator. Although the laboratory has achieved successful scientific results, the performance of the accelerator has been on a decline mainly due to the aging. In the last two and a half years, the tandem accelerator has suffered from the fall of terminal voltage to around 8 MV. However, the experimental studies in the laboratory have been active. The utilization of the polarized beams of protons and deuterons to study the scattering of the p+d system, the use of heavy ion beam for the systematic search for the molecular resonance in relatively heavy systems and for the study on reaction mechanism, the use of both light and heavy ion beams for the studies on nuclear engineering, material science and geological science and so on were carried out. The gamma ray spectroscopic study on the state near yrast line was largely hampered by the accelerator troubles, instead, the collaboration with the Niels Bohr Institute provided a wonderful research ground for the studies. (K.I.)

  13. Beam emittance of the Stony Brook Tandem-LINAC booster

    International Nuclear Information System (INIS)

    Scholldorf, A.H.

    1984-01-01

    This dissertation is primarily a study of the longitudinal and transverse beam emittance of the Stony Brook Heavy Ion Tandem LINAC Accelerator Facility, with a secondary emphasis on the beam dynamical design of two key elements of the system: a low energy double-drift buncher, and an achromatic double-90 0 LINAC injection system. A transverse emittance measuring system consisting of two translation stages controlled by stepper motors is described. Each stage carried a pair of beam defining slits mounted so that both horizontal and vertical emittances could be measured with only linear motion of the stage assembly. Beam currents were measured directly by a low-noise, high-sensitivity electrometer circuit integrated with the second slit-stage assembly. A mini-computer controlled the motors and acquired and displayed the data. Transverse emittance areas of beams of 12 C, 16 O, 32 S, and 58 Ni were measured at ion source extraction potential, after ion source acceleration, after tandem acceleration, and after LINAC acceleration. The results were analyzed in terms of source sputter-cone geometry, angle straggling in gas and foil strippers, and a variety of other factors

  14. Tandem walking as a quick screening test for vestibular disorders.

    Science.gov (United States)

    Cohen, Helen S; Stitz, Jasmine; Sangi-Haghpeykar, Haleh; Williams, Susan P; Mulavara, Ajitkumar P; Peters, Brian T; Bloomberg, Jacob J

    2017-12-11

    Although many screening tests of balance are available, few of them have been well validated for clinical or research uses. The goal of this study was to test an updated version of an old test, Tandem Walking, to determine how useful it is for screening patients with vestibular disorders. Case-control study. Subjects were 90 adult patients with vestibular disorders and 292 healthy adult controls. They were tested on the number of correct tandem steps they could perform with arms crossed and eyes closed in a series of 10 steps. Correct steps could be nonconsecutive. Subjects were given one practice trial with eyes open and three experimental trials with eyes closed. Receiver operating characteristic (ROC), and sensitivity and specificity were calculated. ROC values, sensitivity, and specificity were, at best, only moderate, no matter how the age range was cut. Even for subjects in the age group with the highest ROC value (i.e., age less than 50 years), ROC = 0.8, sensitivity = 0.77, and specificity = 0.72. These results indicate that 23% of patients will not be identified. Therefore, we recommend that if this test is used for screening patients in the clinic or healthy volunteers, the result should be interpreted with care. 3b Laryngoscope, 2017. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.

  15. Carbon nanotube foils for electron stripping in tandem accelerators

    International Nuclear Information System (INIS)

    Reden, Karl von; Zhang Mei; Meigs, Martha; Sichel, Enid; Fang Shaoli; Baughman, Ray H.

    2007-01-01

    Carbon nanotube technology has rapidly advanced in recent years, making it possible to create meter-long, ∼4 cm wide films of multi-walled tubes of less than 3 μg/cm 2 areal density in a bench top open-air procedure. The physical properties of individual carbon nanotubes have been well established, equaling or surpassing electrical and thermal conductivity and mechanical strength of most other materials, graphite in particular. The handling and transport of such nanotube films, dry-mounted self-supporting on metal frames with several cm 2 of open area, is problem-free: the aerogel films having a volumetric density of about 1.5 mg/cm 3 survived the trip by car and air from Dallas to Oak Ridge without blemish. In this paper we will present the results of first tests of these nanotube films as electron stripper media in a tandem accelerator. The tests were performed in the Model 25 URC tandem accelerator of the Holifield radioactive ion beam facility (HRIBF) at Oak Ridge National Laboratory. We will discuss the performance of nanotube films in comparison with chemical vapor deposition and laser-ablated carbon foils

  16. Use of TANDEM methodology for quality control in radiation protection

    International Nuclear Information System (INIS)

    Mello, O.A.; Oliveira, I.R.; Leyton, F.; Nogueira, M.S.; Borges, F.L.S.; Joana, G.S.

    2014-01-01

    Recent studies have indicated the increase of the incidence of lens opacities for low radiation doses. Considering epidemiological data, the International Commission on Radiological Protection (ICRP) issued a statement that changed the absorbed dose threshold for the eye lens. The statement also recommends a reduction in the dose limits to the eye lens for occupationally exposed persons; now it is considered to be 20 mSv in a year averaged over five years. For this research two types of thermoluminescent dosimeters TL were used in the construction of the curve tandem. (LiF-100H e LiF-200). For system calibration three monitors were irradiated for each radiation beam. The monitors were irradiated with 4 mGy kerma at 1.5 m from the focal point. The Tandem curve was obtained by the ratio between the values of the energy dependence curves of each dosimeter. Data obtained for the corresponding x-ray beams to radiation reference N60 to N120 are more accurate for determining the energy - steepest part of the curve. The results are shown similar to similar studies and confirm the possibility of using the method for determining the unknown energy radiation fields. (author)

  17. Vacuum system of tandem type electrostatic accelerator of Kyushu University

    International Nuclear Information System (INIS)

    Nakajima, Yutaka

    1981-01-01

    In the tandem type electrostatic accelerator of Kyushu University, the problem of vacuum in the beam transport system including the accelerator tube has been considered as one of the important elements for the performance of the electrostatic accelerator from the beginning of construction. Though the three-stage tandem accelerating scheme was considered as the beam transport system at the beginning of the program, in which the existing 6 MV Van de Graaf accelerator was to be used as the injector, three types of ion sources are prepared at present; the sputter ion source to generate negative heavy ions, the polarizing ion source to generate negative polarized protons or deuterons, and direct extraction type negative ion source. Ultrahigh evacuating system, in which the sputter ion pump is mainly employed, and the turbo-molecular pump is used supplementarily, was installed in the vacuum system. The vacuum of approximately 10 - 9 Torr level off-beam at the inlet or outlet of the accelerator tube and approximately 10 - 8 Torr level in the tubing section in the center terminal were achieved. Since the upper limit of withstand voltage of the accelerating tube was not able to be satisfied for the insufficient baking at the beginning, it was finally decided that the accelerating tube should be heated by directly supplying power to the electrode through low voltage discharge in the tube. This method enabled the generated voltage at the terminal to exceed 10 MV. (Wakatsuki, Y.)

  18. Two tandemly repeated telomere-associated sequences in Nicotiana plumbaginifolia.

    Science.gov (United States)

    Chen, C M; Wang, C T; Wang, C J; Ho, C H; Kao, Y Y; Chen, C C

    1997-12-01

    Two tandemly repeated telomere-associated sequences, NP3R and NP4R, have been isolated from Nicotiana plumbaginifolia. The length of a repeating unit for NP3R and NP4R is 165 and 180 nucleotides respectively. The abundance of NP3R, NP4R and telomeric repeats is, respectively, 8.4 x 10(4), 6 x 10(3) and 1.5 x 10(6) copies per haploid genome of N. plumbaginifolia. Fluorescence in situ hybridization revealed that NP3R is located at the ends and/or in interstitial regions of all 10 chromosomes and NP4R on the terminal regions of three chromosomes in the haploid genome of N. plumbaginifolia. Sequence homology search revealed that not only are NP3R and NP4R homologous to HRS60 and GRS, respectively, two tandem repeats isolated from N. tabacum, but that NP3R and NP4R are also related to each other, suggesting that they originated from a common ancestral sequence. The role of these repeated sequences in chromosome healing is discussed based on the observation that two to three copies of a telomere-similar sequence were present in each repeating unit of NP3R and NP4R.

  19. The First Tandem, All-exciplex-based WOLED

    Science.gov (United States)

    Hung, Wen-Yi; Fang, Guan-Cheng; Lin, Shih-Wei; Cheng, Shuo-Hsien; Wong, Ken-Tsung; Kuo, Ting-Yi; Chou, Pi-Tai

    2014-06-01

    Exploiting our recently developed bilayer interface methodology, together with a new wide energy-gap, low LUMO acceptor (A) and the designated donor (D) layers, we succeeded in fabricating an exciplex-based organic light-emitting diode (OLED) systematically tuned from blue to red. Further optimization rendered a record-high blue exciplex OLED with ηext of 8%. We then constructed a device structure configured by two parallel blend layers of mCP/PO-T2T and DTAF/PO-T2T, generating blue and yellow exciplex emission, respectively. The resulting device demonstrates for the first time a tandem, all-exciplex-based white-light OLED (WOLED) with excellent efficiencies ηext: 11.6%, ηc: 27.7 cd A-1, and ηp: 15.8 ml W-1 with CIE(0.29, 0.35) and CRI 70.6 that are nearly independent of EL intensity. The tandem architecture and blend-layer D/A (1:1) configuration are two key elements that fully utilize the exciplex delay fluorescence, providing a paragon for the use of low-cost, abundant organic compounds en route to commercial WOLEDs.

  20. Tandem-ESQ for accelerator-based BNCT

    International Nuclear Information System (INIS)

    Kreiner, A.J.; Burlon, A.A.; Di Paolo, H.; Minsky, D.M.; Valda, A.A.; Debray, M.E.; Somacal, H.R.; Kwan, J.W.; Henestroza, E.

    2006-01-01

    A project to develop a Tandem-ElectroStatic-Quadrupole (TESQ) accelerator for Accelerator-Based Boron Neutron Capture Therapy (AB-BNCT) is described. A folded tandem, with 1.25 MV terminal voltage, combined with an ElectroStatic Quadrupole (ESQ) chain is being proposed. The project goal is a machine capable of delivering 30 mA of 2.5 MeV protons to be used in conjunction with a neutron production target based on the 7 Li(p,n) 7 Be reaction beyond its resonance at 2.25 MeV. This machine is conceptually shown to be capable of accelerating a 30 mA proton beam to 2.5 MeV. These are the specifications needed to produce sufficiently intense and clean epithermal neutron beams, based on the '7Li(p,n) 7 Be reaction, to perform BNCT treatment for deep-seated tumors in less than an hour. This electrostatic machine is the technologically simplest and cheapest solution for optimized AB-BNCT. (author)

  1. Development of high current injector for tandem accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Baba, Takashi; Iwamoto, Eiji [Nissin - High Voltage Co. Ltd., Kyoto (Japan); Kishimoto, Naoki; Saito, Tetsuya; Mori, Yoshiharu

    1997-02-01

    The development of the electrostatic type tandem accelerators has been carried out so far, but by the recent remarkable progress of negative ion sources, the beam current which was inconceivable so far has become obtainable, and the use as the electrostatic type tandem accelerators is expanding rapidly. The problem which must be solved in the development of a high energy, large current heavy ion injection device is the development of an injector. As to the generation of negative ions, by the development of plasma sputter negative ion sources, the almost satisfactory performance has been obtained in beam current, emittance, life and so on, but as for the transport and control of generated negative ion beam, there is the large problem of spatial charge effect. This time, the verifying test on this problem was carried out, therefore, its contents and results are reported. The equipment which was developed this time was delivered to the Institute for Materials Research. Its specifications are shown. The whole constitution, negative ion source, and beam transport system are described. Beam generation test and spatial charge effect test are reported. The test stand was made, and in the verifying test, the maximum beams of 4 mA in Cu and 3 mA in Ni were able to be generated and transported. The effect of the countermeasures to spatial charge effect was confirmed. (K.I.)

  2. Installation of an injector for SNICS source of the Tandem Accelerator; Instalacion de un Inyector para fuente SNICS del Acelerador Tandem

    Energy Technology Data Exchange (ETDEWEB)

    Villasenor S, P. [ININ, Centro Nuclear Nabor Carrillo (Mexico)]. e-mail: peguvi@nuclear.inin.mx

    2006-07-01

    Presently work, the adaptation and installation of an accelerating tube (that operates as Injector of 75 KV), to the source of ions 'Sputtering Negative Ion Cesium Source', (SNICS), of the Tandem Accelerator EN of the Nuclear Center is presented. This work allowed to increase the acceleration energy from the negative ions to the beginning of the tank. Since the beam energy that it was possible to obtain from the source, it was very below the design parameters, what limited in great measure the reach of the experiments that could be carried out, was urgent to carry out the installation of the accelerator tube mentioned to the source. The limitations in the available resources had impeded this improvement and it took time being deferred. The added value of this adaptation, it resides in that it is a specialized work and it was, finally, carried out with success by the workers of the Accelerator, adapting to the few existent resources and achieving with it a substantial improvement of the bombing currents obtained for the samples of the investigators. (Author)

  3. Determination of 5-fluorouracil in plasma with HPLC-tandem mass spectrometry

    NARCIS (Netherlands)

    van Kuilenburg, A. B. P.; van Lenthe, H.; Maring, J. G.; van Gennip, A. H.

    2006-01-01

    In this article, we describe a fast and specific method to measure 5FU with HPLC tandem-mass spectrometry. Reversed-phase HPLC was combined with electrospray ionization tandem mass spectrometry and detection was performed by multiple-reaction monitoring. Stable-isotope-labeled 5FU (1,3-15N2-5FU) was

  4. Status of the Catania tandem as injector of the superconducting cyclotron

    International Nuclear Information System (INIS)

    Ciavola, G.; Cuttone, G.; Raia, G.

    1990-01-01

    The Catania LNS tandem facility is operating since 1984. The status and the main modifications of the accelerator during these years are described and the performance obtained is reported. A superconducting cyclotron will be installed at the LNS facility as tandem booster; the main progress is presented. (orig.)

  5. Catalytic stereoselective synthesis of highly substituted indanones via tandem Nazarov cyclization and electrophilic fluorination trapping.

    Science.gov (United States)

    Nie, Jing; Zhu, Hong-Wei; Cui, Han-Feng; Hua, Ming-Qing; Ma, Jun-An

    2007-08-02

    A new catalytic stereoselective tandem transformation via Nazarov cyclization/electrophilic fluorination has been accomplished. This sequence is efficiently catalyzed by a Cu(II) complex to afford fluorine-containing 1-indanone derivatives with two new stereocenters with high diastereoselectivity (trans/cis up to 49/1). Three examples of catalytic enantioselective tandem transformation are presented.

  6. Solution-processed organic tandem solar cells with embedded optical spacers

    NARCIS (Netherlands)

    Hadipour, Afshin; de Boer, Bert; Blom, Paul W. M.

    2007-01-01

    We demonstrate a solution-processed polymer tandem solar cell in which the two photoactive single cells are separated by an optical spacer. The use of an optical spacer allows for an independent optimization of both the electronic and optical properties of the tandem cell. The optical transmission

  7. Analysis of genetic polymorphism of nine short tandem repeat loci in ...

    African Journals Online (AJOL)

    Yomi

    2012-03-15

    Mar 15, 2012 ... Key words: short tandem repeat, repeat motif, genetic polymorphism, Han population, forensic genetics. INTRODUCTION. Short tandem repeat (STR) is widely .... Data analysis. The exact test of Hardy-Weinberg equilibrium was conducted with. Arlequin version 3.5 software (Computational and Molecular.

  8. Simulation of Two Dimensional Electrophoresis and Tandem Mass Spectrometry for Teaching Proteomics

    Science.gov (United States)

    Fisher, Amanda; Sekera, Emily; Payne, Jill; Craig, Paul

    2012-01-01

    In proteomics, complex mixtures of proteins are separated (usually by chromatography or electrophoresis) and identified by mass spectrometry. We have created 2DE Tandem MS, a computer program designed for use in the biochemistry, proteomics, or bioinformatics classroom. It contains two simulations--2D electrophoresis and tandem mass spectrometry.…

  9. Exploring dark current voltage characteristics of micromorph silicon tandem cells with computer simulations

    NARCIS (Netherlands)

    Sturiale, A.; Li, H. B. T.; Rath, J.K.; Schropp, R.E.I.; Rubinelli, F.A.

    2009-01-01

    The transport mechanisms controlling the forward dark current-voltage characteristic of the silicon micromorph tandem solar cell were investigated with numerical modeling techniques. The dark current-voltage characteristics of the micromorph tandem structure at forward voltages show three regions:

  10. Hydra: software for tailored processing of H/D exchange data from MS or tandem MS analyses

    Directory of Open Access Journals (Sweden)

    Bennett Melissa

    2009-05-01

    Full Text Available Abstract Background Hydrogen/deuterium exchange mass spectrometry (H/DX-MS experiments implemented to characterize protein interaction and protein folding generate large quantities of data. Organizing, processing and visualizing data requires an automated solution, particularly when accommodating new tandem mass spectrometry modes for H/DX measurement. We sought to develop software that offers flexibility in defining workflows so as to support exploratory treatments of H/DX-MS data, with a particular focus on the analysis of very large protein systems and the mining of tandem mass spectrometry data. Results We present a software package ("Hydra" that supports both traditional and exploratory treatments of H/DX-MS data. Hydra's software architecture tolerates flexible data analysis procedures by allowing the addition of new algorithms without significant change to the underlying code base. Convenient user interfaces ease the organization of raw data files and input of peptide data. After executing a user-defined workflow, extracted deuterium incorporation values can be visualized in tabular and graphical formats. Hydra also automates the extraction and visualization of deuterium distribution values. Manual validation and assessment of results is aided by an interface that aligns extracted ion chromatograms and mass spectra, while providing a means of rapidly reprocessing the data following manual adjustment. A unique feature of Hydra is the automated processing of tandem mass spectrometry data, demonstrated on a large test data set in which 40,000 deuterium incorporation values were extracted from replicate analysis of approximately 1000 fragment ions in one hour using a typical PC. Conclusion The customizable workflows and user-friendly interfaces of Hydra removes a significant bottleneck in processing and visualizing H/DX-MS data and helps the researcher spend more time executing new experiments and interpreting results. This increased

  11. Zinc tin oxide as high-temperature stable recombination layer for mesoscopic perovskite/silicon monolithic tandem solar cells

    KAUST Repository

    Werner, Jé ré mie; Walter, Arnaud; Rucavado, Esteban; Moon, Soo Jin; Sacchetto, Davide; Rienaecker, Michael; Peibst, Robby; Brendel, Rolf; Niquille, Xavier; De Wolf, Stefaan; Lö per, Philipp; Morales-Masis, Monica; Nicolay, Sylvain; Niesen, Bjoern; Ballif, Christophe

    2016-01-01

    the concept, we fabricate monolithic tandem cells with mesoscopic top cell with up to 16% efficiency. We then investigate the effect of zinc tin oxide layer thickness variation, showing a strong influence on the optical interference pattern within the tandem

  12. Annual report of Department of Research Reactor and Tandem Accelerator, JFY2011. Operation, utilization and technical development of JRR-3, JRR-4, NSRR and tandem accelerator

    International Nuclear Information System (INIS)

    Ishii, Tetsuro; Nakamura, Kiyoshi; Kawamata, Satoshi; Ishikuro, Yasuhiro; Kawashima, Kazuhito; Kabumoto, Hiroshi; Nakamura, Takemi; Tamura, Itaru; Kawasaki, Sayuri; Sataka, Masao

    2013-03-01

    The Department of Research Reactors and Tandem Accelerator is in charge of the operation, utilization and technical development of JRR-3(Japan Research Reactor No.3), JRR-4(Japan Research Reactor No.4), NSRR(Nuclear Safety Research Reactor) and Tandem Accelerator. This annual report describes a summary of activities of services and technical developments carried out in the period between April 1, 2011 and March 31, 2012. The activities were categorized into six service/development fields: (1) Recovery from the Great East Japan Earthquake, (2) Operation and maintenance of research reactors and tandem accelerator, (3) Utilization of research reactors and tandem accelerator, (4) Upgrading of utilization techniques of research reactors and tandem accelerator, (5) Safety administration for research reactors and tandem accelerator, (6) International cooperation. Also contained are lists of publications, meetings, granted permissions on lows and regulations concerning atomic energy, number of staff members dispatched to Fukushima for the technical assistance, commendation, outcomes in service and technical developments and so on. (author)

  13. Use of TANDEM methodology for quality control in radiation protection; Aplicacao de metodologia TANDEM para controle de qualidade em radioprotecao

    Energy Technology Data Exchange (ETDEWEB)

    Mello, O.A.; Oliveira, I.R.; Leyton, F.; Nogueira, M.S., E-mail: mnogueira@cdtn.br [Centro de Desenvolvimeto da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Borges, F.L.S., E-mail: flavialuizaborges@yahoo.com.br [Vigilancia Sanitaria de Minas Gerais, Belo Horizonte, MG (Brazil); Joana, G.S., E-mail: georgia.joana@gmail.com [Universidade Federal de Minas Gerais (DEN/UFMG), Belo Horizonte, MG (Brazil)

    2014-07-01

    Recent studies have indicated the increase of the incidence of lens opacities for low radiation doses. Considering epidemiological data, the International Commission on Radiological Protection (ICRP) issued a statement that changed the absorbed dose threshold for the eye lens. The statement also recommends a reduction in the dose limits to the eye lens for occupationally exposed persons; now it is considered to be 20 mSv in a year averaged over five years. For this research two types of thermoluminescent dosimeters TL were used in the construction of the curve tandem. (LiF-100H e LiF-200). For system calibration three monitors were irradiated for each radiation beam. The monitors were irradiated with 4 mGy kerma at 1.5 m from the focal point. The Tandem curve was obtained by the ratio between the values of the energy dependence curves of each dosimeter. Data obtained for the corresponding x-ray beams to radiation reference N60 to N120 are more accurate for determining the energy - steepest part of the curve. The results are shown similar to similar studies and confirm the possibility of using the method for determining the unknown energy radiation fields. (author)

  14. Tandem Accelerator Center, University of Tsukuba, annual report 1998. April 1, 1998 - March 31, 1999

    International Nuclear Information System (INIS)

    1999-07-01

    The operation of the 12 UD Pelletron tandem accelerators was very stable until December 12, 1998. A total beam time for experiments is 2383 hours. This report describes the activities at Tandem Accelerator Center of the University of Tsukuba in fiscal year 1998. The 32 reports are presented in the 4 categories; that are (1) Accelerator and Experimental Facilities (7 reports), (2) Nuclear Physics (12 reports), (3) Atomic and Solid State Physics, and Cluster Science (10 reports), (4) Ion Beam Application (3 reports). New development of experimental instruments were made on a proton polarimeter at very low energies, a detector of atomic cluster at low velocity, a long focal-plane position sensitive detector, and a liquid-helium-free superconducting solenoid for an Ecr ion source. In the field of nuclear physics, progresses were made in proton total-reaction cross sections, the continuum discretized coupled channel (CDCC) theory, (d, αX) reactions, 7 Li breakup reactions, hole states via (p, d) reaction, and nuclear structure physics by means of in-beam γ ray spectroscopy. New approaches were initiated on the precise measurement of proton-proton elastic scattering to search for magnetic monopole, and on perturbed angular correlations to measure nuclear g-factors in the pico second region. The investigation of ion-induced secondary electron is made in the binary-encounter electron emission from crystalline and non crystalline targets. An applicability of ion-induced Auger electrons to structure analysis was also demonstrated. An experiments of Br and I ions opened a new approach to the study of structural defects in amorphous silica. The study of deuteron implantation into silicon single crystal resulted in an interpretation of macroscopic migration. Microscopic migration was investigated on some metals. In atomic cluster physics, angular distributions of several noble-gas ions were measured to derive a new interaction potential. Mass spectra of semiconductor and 3d

  15. Mass spectrometry and tandem mass spectrometry of citrus limonoids.

    Science.gov (United States)

    Tian, Qingguo; Schwartz, Steven J

    2003-10-15

    Methods for atmospheric pressure chemical ionization tandem mass spectrometry (APCI-MS/MS) of citrus limonoid aglycones and electrospray ionization tandem mass spectrometry (ESI-MS/MS) of limonoid glucosides are reported. The fragmentation patterns of four citrus limonoid aglycones (limonin, nomilin, obacunone, and deacetylnomilin) and six limonoid glucosides, that is, limonin 17-beta-D-glucopyranoside (LG), nomilin 17-beta-D-glucopyranoside (NG), nomilinic acid 17-beta-D-glucopyranoside (NAG), deacetyl nomilinic acid 17-beta-D-glucopyranoside (DNAG), obacunone 17-beta-D-glucopyranoside (OG), and obacunoic acid 17-beta-D-glucopyranoside (OAG) were investigated using a quadruple mass spectrometer in low-energy collisionally activated dissociation (CAD). The four limonoid aglycones and four limonoid glucosides (LG, OG, NAG, and DNAG) were purified from citrus seeds; the other two limonoid glucosides (NG and OAG) were tentatively identified in the crude extract of grapefruit seeds by ESI mass spectrometry in both positive and negative ion analysis. Ammonium hydroxide or acetic acid was added to the mobile phase to facilitate ionization. During positive ion APCI analysis of limonoid aglycones, protonated molecular ion, [M + H]+, or adduct ion, [M + NH3 + H]-, was formed as base peaks when ammonium hydroxide was added to the mobile phase. Molecular anions or adduct ions with acetic acid ([M + HOAc - H] and [M + HOAc]-) or a deprotonated molecular ion were produced during negative ion APCI analysis of limonoid aglycones, depending on the mobile-phase modifier used. Positive ion ESI-MS of limonoid glucosides produced adduct ions of [M + H + NH3]+, [M + Na]+, and [M + K]+ when ammonium hydroxide was added to the mobile phase. After collisionally activated dissociation (CAD) of the limonoid aglycone molecular ions in negative ion APCI analysis, fragment ions indicated structural information of the precursor ions, showing the presence of methyl, carboxyl, and oxygenated ring

  16. 21 CFR 862.1055 - Newborn screening test system for amino acids, free carnitine, and acylcarnitines using tandem...

    Science.gov (United States)

    2010-04-01

    ..., free carnitine, and acylcarnitines using tandem mass spectrometry. 862.1055 Section 862.1055 Food and... screening test system for amino acids, free carnitine, and acylcarnitines using tandem mass spectrometry. (a) Identification. A newborn screening test system for amino acids, free carnitine, and acylcarnitines using tandem...

  17. Multiple analyte adduct formation in liquid chromatography-tandem mass spectrometry - Advantages and limitations in the analysis of biologically-related samples.

    Science.gov (United States)

    Dziadosz, Marek

    2018-05-01

    Multiple analyte adduct formation was examined and discussed in the context of reproducible signal detection in liquid chromatography-tandem mass spectrometry applied in the analysis of biologically-related samples. Appropriate infusion solutions were prepared in H 2 O/methanol (3/97, v/v) with 1 mM sodium acetate and 10 mM acetic acid. An API 4000 QTrap tandem mass spectrometer was used for experiments performed in the negative scan mode (-Q1 MS) and the negative enhanced product ion mode (-EPI). γ‑Hydroxybutyrate and its deuterated form were used as model compounds to highlight both the complexity of adduct formation in popular mobile phases used and the effective signal compensation by the application of isotope-labelled analytes as internal standards. Copyright © 2018 Elsevier B.V. All rights reserved.

  18. The utility of ultra-high performance supercritical fluid chromatography-tandem mass spectrometry (UHPSFC-MS/MS) for clinically relevant steroid analysis.

    Science.gov (United States)

    Storbeck, Karl-Heinz; Gilligan, Lorna; Jenkinson, Carl; Baranowski, Elizabeth S; Quanson, Jonathan L; Arlt, Wiebke; Taylor, Angela E

    2018-05-15

    Liquid chromatography tandem mass spectrometry (LC-MS/MS) assays are considered the reference standard for serum steroid hormone analyses, while full urinary steroid profiles are only achievable by gas chromatography (GC-MS). Both LC-MS/MS and GC-MS have well documented strengths and limitations. Recently, commercial ultra-high performance supercritical fluid chromatography-tandem mass spectrometry (UHPSFC-MS/MS) systems have been developed. These systems combine the resolution of GC with the high-throughput capabilities of UHPLC. Uptake of this new technology into research and clinical labs has been slow, possibly due to the perceived increase in complexity. Here we therefore present fundamental principles of UHPSFC-MS/MS and the likely applications for this technology in the clinical research setting, while commenting on potential hurdles based on our experience to date. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.

  19. Annual report of the Tandem Accelerator Center, University of Tsukuba, 1987

    International Nuclear Information System (INIS)

    1988-07-01

    This annual report covers the research activities and technical developments of the Tandem Accelerator Center, University of Tsukuba, in the period from April, 1987 to March, 1988. In the field of nuclear physics, the elastic and inelastic scattering of polarized protons from even-even medium weight nuclei was investigated systematically by light ion beam experiment. A QDQ type magnetic spectrograph for double scattering experiment was almost complete. The studies on heavy ion-induced fission reaction advanced by measuring anisotropy in fission angular distribution, and a view on the mechanism of the reaction was acquired. A new, ingenious technique enabled to identify prompt characteristics X-ray accompanying the fusion reaction induced by heavy ions. In the field of atomic and solid state physics, a strange dependence of equilibrium charge state on the atomic number of projectile heavy ions has been elucidated. The research on ion beam shadowing effect on the emission of ion-induced secondary electrons was continued. The Rutherford backscattering of O 4+ ions was applied to determine the composition of Y-Ba-Cu oxide film, and it shed light on the condition governing the nature of superconductive materials. The 12 UD Pelletron was operated quite satisfactorily. (Kako, I.)

  20. Annual report of the Tandem Accelerator Center, Nuclear and Solid State Research Project, University of Tsukuba

    International Nuclear Information System (INIS)

    1981-01-01

    During the academic year 1980 - 1981, the 12 UD Pelletron tandem accelerator in UTTAC has experienced several troubles. The accelerator tank had to be opened six times including the scheduled overhaul. Due to these troubles, both the beam time and the chain operation time were reduced by 20% as compared with the preceding year. However, the beam pulsing system was completed, and pulsed beam has been in use. The polarized ion source and the sputter ion source have worked well. A heavy ion booster with interdigital H-structure was designed, and has been under construction. Special efforts have been exerted on the detectors and detector systems. The examples of the achievements mainly associated with the Nuclear and Solid State Research Project are enumerated as follows. The complete experiment on d-p system provided the data on nuclear three body problem. The information about the mechanism of two-nucleon transfer reaction (p,t) was obtained. The mechanisms of (p,p) and (p,d) reactions were clarified. The experiment on the measurement of the magnetic moment of β-emitting products with polarized beam began. The properties of very highly excited states were clarified by the study of heavy ion-induced reactions. A new model for heavy ion fusion reaction was proposed. The mechanism of inner shell ionization was clarified by passing heavy ions through solids. (Kako, I.)

  1. Annual report of the Tandem Accelerator Center, University of Tsukuba. April 1, 1995 - March 31, 1996

    International Nuclear Information System (INIS)

    1996-10-01

    This annual report includes the research activities from April, 1995 to March, 1996. The 12 UD Pelletron tandem accelerator has been operated successfully to provide sufficient beam time for experiments. The stable operation of the accelerator brought out steady advances in many investigations continued as long range projects. Those are polarization phenomena in nuclear reactions, the nonresonant breakup of Li-7, further refinement of continuum discretized coupled channels theory, fusion and fission in heavy ion reactions, nuclear structure physics by means of in-beam γ ray spectroscopy, solid state physics using fast ion beams, Moessbauer effect, NMR, and the application of accelerated ion beams to PIXE and accelerator mass spectrometry. As the new developments of experimental instruments, an ion source for micro-cluster beams and a pulsing system for low velocity cluster ions have been successfully constructed. A beam line producing proton micro-beam has been constructed. In this report, the accelerator and experimental facilities, the experiments and theories of nuclear physics, atomic and solid state physics, ion beam applications, publications, theses and seminars, and personnel are reported. (K.I.)

  2. Physics-magnetics trade studies for tandem mirror reactors

    International Nuclear Information System (INIS)

    Campbell, R.B.; Perkins, L.J.; Blackfield, D.T.

    1985-01-01

    We describe and present results obtained from the optimization package of the Tandem Mirror Reactor Systems Code. We have found it to be very useful in searching through multidimensional parameter space, and have applied it here to study the effect of choke coil field strength and net electric power on cost of electricity (COE) and mass utilization factor (MUF) for MINIMARS type reactors. We have found that a broad optimum occurs at B/sub choke/ = 26 T for both COE and MUF. The COE economy of scale approaches saturation at quite low powers, around 600 MW(e). The saturation is mainly due to longer construction times for large plants, and the associated time related costs. The MUF economy of scale does not saturate, at least for powers up to 2400 MW(e)

  3. Configuration and layout of the tandem mirror Fusion Power Demonstrator

    International Nuclear Information System (INIS)

    Clarkson, I.R.; Neef, W.S.

    1983-01-01

    Studies have been performed during the past year to determine the configuration of a tandem mirror Fusion Power Demonstrator (FPD) machine capable of producing 1750 MW of fusion power. The FPD is seen as the next logical step after the Mirror Fusion Test Facility-B (MFTF-B) toward operation of a power reactor. The design of the FPD machine allows a phased construction: Phase I, a hydrogen or deuterium checkout machine; Phase 2, a DT breakeven machine; Phase 3, development of the Phase 2 machine to provide net power and act as a reactor demonstrator. These phases are essential to the development of remote handling equipment and the design of components that will ultimately be remotely handled. Phasing also permits more modes funding early in the program with some costs committed only after reaching major milestones

  4. The tandem Tritron control system, a status report

    International Nuclear Information System (INIS)

    Rohrer, L.; Schnitter, H.; Cazan, A.; Jakubowska, E.; Walchshaeusl, B.

    1994-01-01

    The control system for the tandem accelerator and the Tritron was put into operation in 1988 and has been developed further continuously. It consists of many Z280 microcomputer crates, equipped with I/O-boards to control accelerator devices, personal computers serving as control desks, a file server, an address server, and an error logger. All computers are interconnected by an ARCnet local area network. The program language in every computer and the communication language is FORTH. Every node contains a multitasking FORTH system with floating point arithmetic from the beginning and interprets or compiles the data stream coming from the ARCnet. Each node is programmed with its special program so that it can perform its specific control or monitor task. The system is very flexible. Every node may be changed or replaced by a better one, if necessary. The only condition is that it can be connected to the ARCnet and can be programmed in FORTH. ((orig.))

  5. Analysis and simulation of an electrostatic FN Tandem accelerator

    International Nuclear Information System (INIS)

    Ugarte, Ricardo

    2007-01-01

    An analysis, modeling, and simulation of a positive ion FN Tandem electrostatic accelerator has been done. That has induced a detailed study over all physics components inside the accelerators tank, the terminal control stabilizer (TPS), the corona point, the capacitor pick off (CPO) and over the generating voltmeter (GVM) signals. The parameter of the model has been developed using the Prediction Error estimation Methods (PEM), and within classical techniques of analysis of circuits. The result obtained was used to check and increase the stability of the terminal voltage using Matlab software tools. The result of the simulation was contrasted with the reality and it was possible to improve the stability of the terminal voltage, successfully. The facility belongs to ARN (Argentina) and, in principle, it was installed to development an AMS system. (author)

  6. Materials science symposium 'heavy ion science in tandem energy region'

    International Nuclear Information System (INIS)

    Iwamoto, Akira; Yoshida, Tadashi; Takeuchi, Suehiro

    2001-11-01

    The facility of the JAERI tandem accelerator and its booster has been contributing to obtain plenty of fruitful results in the fields of nuclear physics, nuclear chemistry, atomic and solid state physics and materials science, taking an advantage of its prominent performances of heavy ion acceleration. The previous meeting held in 1999 also offered an opportunity to scientists from all over the heavy ion science fields, including nuclear physics, solid state physics and cross-field physics to have active discussions. This meeting included oral presentations with a new plan and with a new scope of fields expected from now on, as an occasion for opening the 21st century in heavy ion science. The 50 of the presented papers are indexed individually. (J.P.N.)

  7. Energy calibration of the 3 MV tandem accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Bunnak, S; Mizuhashi, K; Tajima, S

    1996-12-01

    By this study, a graphite calorimeter has been developed to measure the average ion energy from electrostatic ion accelerator (3 MV Tandem Ion Accelerator of the Takasaki Ion Accelerators for Advanced Radiation Application). A graphite calorimeter was designed for measuring the ion beam energy in wide ion energy ranges (from 3 MeV to 10 MeV). By a couple of this study, the {sup 1} H({sup 15} N, {alpha} {gamma}) {sup 12} C resonant nuclear reactions (resonant energy 6.385 MeV and 13.355 MeV) has been applied for measuring the absolute ion beam energy serve as a comparative method. The obtained results were compared in terms of resolution and accuracy. Close agreement was found for both methods, the deviation was observed within {+-} 3%

  8. United theory of planet formation (i): Tandem regime

    Science.gov (United States)

    Ebisuzaki, Toshikazu; Imaeda, Yusuke

    2017-07-01

    The present paper is the first one of a series of papers that present the new united theory of planet formation, which includes magneto-rotational instability and porous aggregation of solid particles in an consistent way. We here describe the ;tandem; planet formation regime, in which a solar system like planetary systems are likely to be produced. We have obtained a steady-state, 1-D model of the accretion disk of a protostar taking into account the magneto-rotational instability (MRI) and and porous aggregation of solid particles. We find that the disk is divided into an outer turbulent region (OTR), a MRI suppressed region (MSR), and an inner turbulent region (ITR). The outer turbulent region is fully turbulent because of MRI. However, in the range, rout(= 8 - 60 AU) from the central star, MRI is suppressed around the midplane of the gas disk and a quiet area without turbulence appears, because the degree of ionization of gas becomes low enough. The disk becomes fully turbulent again in the range rin(= 0.2 - 1 AU), which is called the inner turbulent region, because the midplane temperature become high enough (>1000 K) due to gravitational energy release. Planetesimals are formed through gravitational instability at the outer and inner MRI fronts (the boundaries between the MRI suppressed region (MSR) and the outer and inner turbuent regions) without particle enhancement in the original nebula composition, because of the radial concentration of the solid particles. At the outer MRI front, icy particles grow through low-velocity collisions into porous aggregates with low densities (down to ∼10-5 gcm-3). They eventually undergo gravitational instability to form icy planetesimals. On the other hand, rocky particles accumulate at the inner MRI front, since their drift velocities turn outward due to the local maximum in gas pressure. They undergo gravitational instability in a sub-disk of pebbles to form rocky planetesimals at the inner MRI front. They are likely

  9. Research on optimizing pass schedule of tandem cold mill

    International Nuclear Information System (INIS)

    Lu, C.; Wang, J.S.; Zhao, Q.L.; Liu, X.H.; Wang, G.D.

    2000-01-01

    In this paper, research on pass schedule of tandem cold mill (TCM) is carried out. According to load (reduction, rolling force, motor power) balance, non-linear equations set with variables of inter-stand thickness is constructed. The pass schedule optimization is carried out by solving the non-linear equations set. As the traditional method, the Newton-Raphson method is used for solving the non-linear equations set. In this paper a new simple method is brought up. On basis of the monotone relations between thickness and load, the inter-stands thickness is adjusted dynamically. The solution of non-linear equations set can be converged by iterative calculation. This method can avoid the derivative calculation used by traditional method. So, this method is simple and calculation speed is high. It is suitable for on-line control. (author)

  10. Physics issues in mirror and tandem mirror systems

    International Nuclear Information System (INIS)

    Post, R.F.

    1984-01-01

    Over the years the study of the confinement of high temperature plasma in magnetic mirror systems has presented researchers with many unusual physics problems. Many of these issues are by now understood theoretically and documented experimentally. With the advent of the tandem mirror idea, some new issues have emerged and are now under intensive study. These include: (1) the generation and control of ambipolar confining potentials and their effect on axial confinement and, (2) the combined influence of nonaxisymmetric magnetic fields (used to ensure MHD stability) and electric magnetic particle drifts on radial transport. Physics considerations associated with these two categories of issues will be reviewed, including concepts for the control of radial transport, under study or proposed

  11. Tandem mirror magnet system for the mirror fusion test facility

    International Nuclear Information System (INIS)

    Bulmer, R.H.; Van Sant, J.H.

    1980-01-01

    The Tandem Mirror Fusion Test Facility (MFTF-B) will be a large magnetic fusion experimental facility containing 22 supercounducting magnets including solenoids and C-coils. State-of-the-art technology will be used extensively to complete this facility before 1985. Niobium titanium superconductor and stainless steel structural cases will be the principle materials of construction. Cooling will be pool boiling and thermosiphon flow of 4.5 K liquid helium. Combined weight of the magnets will be over 1500 tonnes and the stored energy will be over 1600 MJ. Magnetic field strength in some coils will be more than 8 T. Detail design of the magnet system will begin early 1981. Basic requirements and conceptual design are disclosed in this paper

  12. Potential measurement and radial transport in GAMMA 10 tandem mirror

    International Nuclear Information System (INIS)

    Ishii, K.; Katanuma, I.; Segawa, T.; Ohkawara, H.; Mase, A.; Miyoshi, S.

    1989-01-01

    GAMMA 10 is an effectively axisymmetric tandem mirror with thermal barriers. Potential information is important to investigate the plasma confinement. The barrier and central space potentials are determined by means of two gold neutral beam probes. Two-dimensional potential profiles have been measured in the barrier cell. In GAMMA 10, to assure magneto-hydrodynamic (MHD) stability, the nonaxisymmetric minimum-B mirror cells are contained between the central-solenoid and the plug/barrier cells at the ends of the machine. From the point of view of neoclassical resonant-plateau transport in circular equipotential contours, this effective axisymmetrization is successful. The measured potential profiles are slightly elongated during the onset of ω ce ECRH. In this paper we report the beam probe potential measurement, the neoclassical ion radial transport in the noncircular equipotential surface and the thermal barrier potential. (author) 6 refs., 5 figs

  13. Structural Basis of Actin Filament Nucleation by Tandem W Domains

    Science.gov (United States)

    Chen, Xiaorui; Ni, Fengyun; Tian, Xia; Kondrashkina, Elena; Wang, Qinghua; Ma, Jianpeng

    2013-01-01

    SUMMARY Spontaneous nucleation of actin is very inefficient in cells. To overcome this barrier, cells have evolved a set of actin filament nucleators to promote rapid nucleation and polymerization in response to specific stimuli. However, the molecular mechanism of actin nucleation remains poorly understood. This is hindered largely by the fact that actin nucleus, once formed, rapidly polymerizes into filament, thus making it impossible to capture stable multisubunit actin nucleus. Here, we report an effective double-mutant strategy to stabilize actin nucleus by preventing further polymerization. Employing this strategy, we solved the crystal structure of AMPPNP-actin in complex with the first two tandem W domains of Cordon-bleu (Cobl), a potent actin filament nucleator. Further sequence comparison and functional studies suggest that the nucleation mechanism of Cobl is probably shared by the p53 cofactor JMY, but not Spire. Moreover, the double-mutant strategy opens the way for atomic mechanistic study of actin nucleation and polymerization. PMID:23727244

  14. Pebble bed blanket design for deuterium burning tandem mirror reactors

    International Nuclear Information System (INIS)

    Grotz, S.P.; Dhir, V.K.

    1983-01-01

    The UCLA tandem mirror reactor, SATYR, was developed around the capability of tandem mirrors with thermal barriers to burn deuterium at reasonable efficiency levels. The pebble bed concept has been incorporated into our blanket design for the following reasons: 1) Large area-to-volume ratio for purposes of heat removal; 2) Large volume of structure for high thermal capacity thus increasing the safety margin during off-normal incidents; 3) Relatively inexpensive manufacturing costs because of large acceptable tolerances and lack of exotic materials (i.e., lithium). A simplified stress analysis of the blanket module was performed to optimize and simplify the design. The pre-specified stress intensity limitations used were based upon a 30-year predicted lifetime for each module. Along with stress analysis of the vessel a detailed thermal hydraulic analysis of the pebble bed has been completed. Parameters affecting the pebble bed design are fluidization velocity, pressure drop, heat transfer coefficient, thermally induced stress in the spheres and spatial variation of the power density. Although reasonable gross thermal efficiencies of the 2 designs has been achieved (28% for H 2 O and 39% for He) the high net recirculating power fraction for heating and neutral beams results in relatively low net plant efficiencies (21% and 27%). The results show that a blanket can be designed with good thermal efficiency and a relative-ly simple configuration. However, application of this concept to the high Q deuterium-tritium fuel cycle would have difficulties resulting from the need for continuous removal of the tritium. (orig./HP)

  15. Novel product ions of 2-aminoanilide and benzimidazole Ag(I) complexes using electrospray ionization with multi-stage tandem mass spectrometry.

    Science.gov (United States)

    Johnson, Byron S; Burinsky, David J; Burova, Svetlana A; Davis, Roman; Fitzgerald, Russ N; Matsuoka, Richard T

    2012-05-15

    The 2-aminoaniline scaffold is of significant value to the pharmaceutical industry and is embedded in a number of pharmacophores including 2-aminoanilides and benzimidazoles. A novel application of coordination ion spray mass spectrometry (CIS-MS) for interrogating the silver ion (Ag(+)) complexes of a homologous series of these compounds using multi-stage tandem mass spectrometry is described. Unlike the ubiquitous alkali metal ion complexes, Ag(+) complexes of 2-aminoanilides and benzimidazoles were found to yield [M - H](+) ions in significant abundance via gas-phase elimination of the metal hydride (AgH) resulting in unique product ion cascades. Sample introduction was by liquid chromatography with mass spectrometry analysis performed on a hybrid linear ion trap/orbitrap instrument capable of high-resolution measurements. Rigorous structural characterization by multi-stage tandem mass spectrometry using [M +  H](+), [M - H](-) and [M - H](+) precursor ions derived from ESI and CIS experiments was performed for the homologous series of 2-aminoanilide and benzimidazole compounds. A full tabular comparison of structural information resulting from these product ion cascades was produced. Multi-stage tandem mass spectrometry of [M - H](+) ions resulting from Ag(+) complexes of 2-aminoanilides and benzimidazoles in CIS-MS experiments produced unique product ion cascades that exhibited complementary structural information to that obtained from tandem mass spectrometry of [M  +  H](+) and [M - H](-) ions by electrospray ionization (ESI). These observations may be broadly applicable to other compounds that are observed to form Ag(+) complexes and eliminate AgH. Copyright © 2012 John Wiley & Sons, Ltd.

  16. Note: Tandem Kirkpatrick-Baez microscope with sixteen channels for high-resolution laser-plasma diagnostics

    Science.gov (United States)

    Yi, Shengzhen; Zhang, Zhe; Huang, Qiushi; Zhang, Zhong; Wang, Zhanshan; Wei, Lai; Liu, Dongxiao; Cao, Leifeng; Gu, Yuqiu

    2018-03-01

    Multi-channel Kirkpatrick-Baez (KB) microscopes, which have better resolution and collection efficiency than pinhole cameras, have been widely used in laser inertial confinement fusion to diagnose time evolution of the target implosion. In this study, a tandem multi-channel KB microscope was developed to have sixteen imaging channels with the precise control of spatial resolution and image intervals. This precise control was created using a coarse assembly of mirror pairs with high-accuracy optical prisms, followed by precise adjustment in real-time x-ray imaging experiments. The multilayers coated on the KB mirrors were designed to have substantially the same reflectivity to obtain a uniform brightness of different images for laser-plasma temperature analysis. The study provides a practicable method to achieve the optimum performance of the microscope for future high-resolution applications in inertial confinement fusion experiments.

  17. Tunable color parallel tandem organic light emitting devices with carbon nanotube and metallic sheet interlayers

    Energy Technology Data Exchange (ETDEWEB)

    Oliva, Jorge; Desirena, Haggeo; De la Rosa, Elder [Centro de Investigaciones en Optica, A.P. 1-948, León, Guanajuato 37160 (Mexico); Papadimitratos, Alexios [Solarno Inc., Coppell, Texas 75019 (United States); University of Texas at Dallas, Richardson, Texas 75080 (United States); Zakhidov, Anvar A., E-mail: Zakhidov@utdallas.edu [Solarno Inc., Coppell, Texas 75019 (United States); University of Texas at Dallas, Richardson, Texas 75080 (United States); Energy Efficiency Center, National University of Science and Technology, MISiS, Moscow 119049 (Russian Federation)

    2015-11-21

    Parallel tandem organic light emitting devices (OLEDs) were fabricated with transparent multiwall carbon nanotube sheets (MWCNT) and thin metal films (Al, Ag) as interlayers. In parallel monolithic tandem architecture, the MWCNT (or metallic films) interlayers are an active electrode which injects similar charges into subunits. In the case of parallel tandems with common anode (C.A.) of this study, holes are injected into top and bottom subunits from the common interlayer electrode; whereas in the configuration of common cathode (C.C.), electrons are injected into the top and bottom subunits. Both subunits of the tandem can thus be monolithically connected functionally in an active structure in which each subunit can be electrically addressed separately. Our tandem OLEDs have a polymer as emitter in the bottom subunit and a small molecule emitter in the top subunit. We also compared the performance of the parallel tandem with that of in series and the additional advantages of the parallel architecture over the in-series were: tunable chromaticity, lower voltage operation, and higher brightness. Finally, we demonstrate that processing of the MWCNT sheets as a common anode in parallel tandems is an easy and low cost process, since their integration as electrodes in OLEDs is achieved by simple dry lamination process.

  18. DNA Damage by Ionizing Radiation: Tandem Double Lesions by Charged Particles

    Science.gov (United States)

    Huo, Winifred M.; Chaban, Galina M.; Wang, Dunyou; Dateo, Christopher E.

    2005-01-01

    Oxidative damages by ionizing radiation are the source of radiation-induced carcinogenesis, damage to the central nervous system, lowering of the immune response, as well as other radiation-induced damages to human health. Monte Carlo track simulations and kinetic modeling of radiation damages to the DNA employ available molecular and cellular data to simulate the biological effect of high and low LET radiation io the DNA. While the simulations predict single and double strand breaks and base damages, so far all complex lesions are the result of stochastic coincidence from independent processes. Tandem double lesions have not yet been taken into account. Unlike the standard double lesions that are produced by two separate attacks by charged particles or radicals, tandem double lesions are produced by one single attack. The standard double lesions dominate at the high dosage regime. On the other hand, tandem double lesions do not depend on stochastic coincidences and become important at the low dosage regime of particular interest to NASA. Tandem double lesions by hydroxyl radical attack of guanine in isolated DNA have been reported at a dosage of radiation as low as 10 Gy. The formation of two tandem base lesions was found to be linear with the applied doses, a characteristic of tandem lesions. However, tandem double lesions from attack by a charged particle have not been reported.

  19. Targeted tandem duplication of a large chromosomal segment in Aspergillus oryzae.

    Science.gov (United States)

    Takahashi, Tadashi; Sato, Atsushi; Ogawa, Masahiro; Hanya, Yoshiki; Oguma, Tetsuya

    2014-08-01

    We describe here the first successful construction of a targeted tandem duplication of a large chromosomal segment in Aspergillus oryzae. The targeted tandem chromosomal duplication was achieved by using strains that had a 5'-deleted pyrG upstream of the region targeted for tandem chromosomal duplication and a 3'-deleted pyrG downstream of the target region. Consequently,strains bearing a 210-kb targeted tandem chromosomal duplication near the centromeric region of chromosome 8 and strains bearing a targeted tandem chromosomal duplication of a 700-kb region of chromosome 2 were successfully constructed. The strains bearing the tandem chromosomal duplication were efficiently obtained from the regenerated protoplast of the parental strains. However, the generation of the chromosomal duplication did not depend on the introduction of double-stranded breaks(DSBs) by I-SceI. The chromosomal duplications of these strains were stably maintained after five generations of culture under nonselective conditions. The strains bearing the tandem chromosomal duplication in the 700-kb region of chromosome 2 showed highly increased protease activity in solid-state culture, indicating that the duplication of large chromosomal segments could be a useful new breeding technology and gene analysis method.

  20. Complete Analysis of a Biologically Active Tetrapeptide: A Project Utilizing Thin-Layer Chromatography and Tandem Quadrupole Mass Spectrometry

    Science.gov (United States)

    Lefevre, Joseph W.; Dodsworth, David W.

    2000-04-01

    The biologically active tetrapeptide d-Ala-Gly-l-Phe-d-Leu ([des-Tyr1-d-Ala2-d-Leu5]enkephalin) was analyzed for its amino acid content and stereochemistry by normal and reversed-phase thin-layer chromatography (TLC), and its sequence was determined by tandem quadrupole mass spectrometry. The project involved sequential N-dansylation of a portion of the tetrapeptide, hydrolysis, isolation, and identification of the N-terminal amino acid as dansyl-alanine by comparison with standards using normal-phase TLC. A second portion of the tetrapeptide was hydrolyzed and the resulting four free amino acids were converted to their corresponding dansyl derivatives and purified by preparative normal-phase TLC. The three dansyl amino acids not identified previously were identified by TLC. The stereochemistry of each was determined by comparison with dansyl-dl-amino acid standards using reversed-phase TLC in the presence of ß-cyclodextrin, a chiral mobile phase additive. Finally, the correct amino acid sequence was determined by tandem quadrupole mass spectrometry. This project gives students valuable experience in microscale synthesis, both normal and reversed-phase TLC, stereochemical analysis, and mass spectrometry.