WorldWideScience

Sample records for tesla technical field

  1. Magnetic field calculations for the technical proposal of the TESLA spectrometer magnet

    International Nuclear Information System (INIS)

    Morozov, N.A.; Schreiber, H.J.

    2003-01-01

    The TESLA electron-positron linear collider is under consideration at DESY (Hamburg). The realization of the physical program at this collider requires the knowledge of the beam energy of both beams (e + and e - ) with a precision of ΔE/E ≤ 10 -4 . The magnetic spectrometer was proposed as an energy measuring device. The report describes calculations for the preliminary conceptual design of this type of the spectrometer. The 2D calculations of the magnetic field for the spectrometer magnet have been performed by POISSON SUPERFISH computer code. The basic technical parameters of the magnet have been determined. These data will serve as a basis for the technical design of the spectrometer magnet and discuss its integration in the spectrometer

  2. Technical challenges of superconductivity and cryogenics in pursuing TESLA-TTF

    International Nuclear Information System (INIS)

    Shu, Quan-Sheng

    1996-01-01

    TESLA (TeV Energy Superconducting Linear Accelerator) Collaboration is an international R ampersand D effort towards the development of an e + e - linear collider with 500 GeV center of mass by means of 20 km active superconducting accelerating structures at a frequency of 1.3 GHz. The ultimate challenges faced by the TESLA project are (1) to raise operational accelerating gradients to 25 MV/m from current world level of 5-10 MV/m, and (2) to reduce construction costs (cryomodules, klystrons, etc.) down to $2,000/MV from now about $40,000/MV. The TESLA Collaboration is building a prototype TESLA test facility (TTF) of a 500 MeV superconducting linear accelerator to establish the technical basis. TTF is presently under construction and will be commissioned at DESY in 1997, through the joint efforts of 24 laboratories from 8 countries. Significant progress has been made in reaching the high accelerating gradient of 25 MV/m in superconducting cavities, developing cryomodules and constructing TTF infrastructure, etc. This paper will briefly discuss the challenges being faced and review the progress achieved in the technical area of superconductivity and cryogenics by the TESLA Collaboration

  3. Nikola Tesla: the man behind the magnetic field unit.

    Science.gov (United States)

    Roguin, Ariel

    2004-03-01

    The magnetic field strength of both the magnet and gradient coils used in MR imaging equipment is measured in Tesla units, which are named for Nikola Tesla. This article presents the life and achievements of this Serbian-American inventor and researcher who discovered the rotating magnetic field, the basis of most alternating-current machinery. Nikola Tesla had 700 patents in the United States and Europe that covered every aspect of science and technology. Tesla's discoveries include the Tesla coil, AC electrical conduction, improved lighting, newer forms of turbine engines, robotics, fluorescent light, wireless transmission of electrical energy, radio, remote control, discovery of cosmic radio waves, and the use of the ionosphere for scientific purposes. He was a genius whose discoveries had a pivotal role in advancing us into the modern era. Copyright 2004 Wiley-Liss, Inc.

  4. Functionality of veterinary identification microchips following low- (0.5 tesla) and high-field (3 tesla) magnetic resonance imaging.

    Science.gov (United States)

    Piesnack, Susann; Frame, Mairi E; Oechtering, Gerhard; Ludewig, Eberhard

    2013-01-01

    The ability to read patient identification microchips relies on the use of radiofrequency pulses. Since radiofrequency pulses also form an integral part of the magnetic resonance imaging (MRI) process, the possibility of loss of microchip function during MRI scanning is of concern. Previous clinical trials have shown microchip function to be unaffected by MR imaging using a field strength of 1 Tesla and 1.5. As veterinary MRI scanners range widely in field strength, this study was devised to determine whether exposure to lower or higher field strengths than 1 Tesla would affect the function of different types of microchip. In a phantom study, a total of 300 International Standards Organisation (ISO)-approved microchips (100 each of three different types: ISO FDX-B 1.4 × 9 mm, ISO FDX-B 2.12 × 12 mm, ISO HDX 3.8 × 23 mm) were tested in a low field (0.5) and a high field scanner (3.0 Tesla). A total of 50 microchips of each type were tested in each scanner. The phantom was composed of a fluid-filled freezer pack onto which a plastic pillow and a cardboard strip with affixed microchips were positioned. Following an MRI scan protocol simulating a head study, all of the microchips were accurately readable. Neither 0.5 nor 3 Tesla imaging affected microchip function in this study. © 2013 Veterinary Radiology & Ultrasound.

  5. 4.5 Tesla magnetic field reduces range of high-energy positrons -- Potential implications for positron emission tomography

    International Nuclear Information System (INIS)

    Wirrwar, A.; Vosberg, H.; Herzog, H.; Halling, H.; Weber, S.; Mueller-Gaertner, H.W.; Forschungszentrum Juelich GmbH

    1997-01-01

    The authors have theoretically and experimentally investigated the extent to which homogeneous magnetic fields up to 7 Tesla reduce the spatial distance positrons travel before annihilation (positron range). Computer simulations of a noncoincident detector design using a Monte Carlo algorithm calculated the positron range as a function of positron energy and magnetic field strength. The simulation predicted improvements in resolution, defined as full-width at half-maximum (FWHM) of the line-spread function (LSF) for a magnetic field strength up to 7 Tesla: negligible for F-18, from 3.35 mm to 2.73 mm for Ga-68 and from 3.66 mm to 2.68 mm for Rb-82. Also a substantial noise suppression was observed, described by the full-width at tenth-maximum (FWTM) for higher positron energies. The experimental approach confirmed an improvement in resolution for Ga-68 from 3.54 mm at 0 Tesla to 2.99 mm FWHM at 4.5 Tesla and practically no improvement for F-18 (2.97 mm at 0 Tesla and 2.95 mm at 4.5 Tesla). It is concluded that the simulation model is appropriate and that a homogeneous static magnetic field of 4.5 Tesla reduces the range of high-energy positrons to an extent that may improve spatial resolution in positron emission tomography

  6. Quantitative techniques for musculoskeletal MRI at 7 Tesla.

    Science.gov (United States)

    Bangerter, Neal K; Taylor, Meredith D; Tarbox, Grayson J; Palmer, Antony J; Park, Daniel J

    2016-12-01

    Whole-body 7 Tesla MRI scanners have been approved solely for research since they appeared on the market over 10 years ago, but may soon be approved for selected clinical neurological and musculoskeletal applications in both the EU and the United States. There has been considerable research work on musculoskeletal applications at 7 Tesla over the past decade, including techniques for ultra-high resolution morphological imaging, 3D T2 and T2* mapping, ultra-short TE applications, diffusion tensor imaging of cartilage, and several techniques for assessing proteoglycan content in cartilage. Most of this work has been done in the knee or other extremities, due to technical difficulties associated with scanning areas such as the hip and torso at 7 Tesla. In this manuscript, we first provide some technical context for 7 Tesla imaging, including challenges and potential advantages. We then review the major quantitative MRI techniques being applied to musculoskeletal applications on 7 Tesla whole-body systems.

  7. Photon collider at TESLA

    International Nuclear Information System (INIS)

    Telnov, Valery

    2001-01-01

    High energy photon colliders (γγ, γe) based on backward Compton scattering of laser light is a very natural addition to e + e - linear colliders. In this report, we consider this option for the TESLA project. Recent study has shown that the horizontal emittance in the TESLA damping ring can be further decreased by a factor of four. In this case, the γγ luminosity in the high energy part of spectrum can reach about (1/3)L e + e - . Typical cross-sections of interesting processes in γγ collisions are higher than those in e + e - collisions by about one order of magnitude, so the number of events in γγ collisions will be more than that in e + e - collisions. Photon colliders can, certainly, give additional information and they are the best for the study of many phenomena. The main question is now the technical feasibility. The key new element in photon colliders is a very powerful laser system. An external optical cavity is a promising approach for the TESLA project. A free electron laser is another option. However, a more straightforward solution is ''an optical storage ring (optical trap)'' with a diode pumped solid state laser injector which is today technically feasible. This paper briefly reviews the status of a photon collider based on the linear collider TESLA, its possible parameters and existing problems

  8. [Studies of three-dimensional cardiac late gadolinium enhancement MRI at 3.0 Tesla].

    Science.gov (United States)

    Ishimoto, Takeshi; Ishihara, Masaru; Ikeda, Takayuki; Kawakami, Momoe

    2008-12-20

    Cardiac late Gadolinium enhancement MR imaging has been shown to allow assessment of myocardial viability in patients with ischemic heart disease. The current standard approach is a 3D inversion recovery sequence at 1.5 Tesla. The aims of this study were to evaluate the technique feasibility and clinical utility of MR viability imaging at 3.0 Tesla in patients with myocardial infarction and cardiomyopathy. In phantom and volunteer studies, the inversion time required to suppress the signal of interests and tissues was prolonged at 3.0 Tesla. In the clinical study, the average inversion time to suppress the signal of myocardium at 3.0 Tesla with respect to MR viability imaging at 1.5 Tesla was at 15 min after the administration of contrast agent (304.0+/-29.2 at 3.0 Tesla vs. 283.9+/-20.9 at 1.5 Tesla). The contrast between infarction and viable myocardium was equal at both field strengths (4.06+/-1.30 at 3.0 Tesla vs. 4.42+/-1.85 at 1.5 Tesla). Even at this early stage, MR viability imaging at 3.0 Tesla provides high quality images in patients with myocardial infarction. The inversion time is significantly prolonged at 3.0 Tesla. The contrast between infarction and viable myocardium at 3.0 Tesla are equal to 1.5 Tesla. Further investigation is needed for this technical improvement, for clinical evaluation, and for limitations.

  9. Report on the TESLA Engineering Study/Review

    Energy Technology Data Exchange (ETDEWEB)

    Cornuelle, John C.

    2002-08-30

    In March, 2001, the TESLA Collaboration published its Technical Design Report (TDR, see references and links in Appendix), the first sentence of which stated ''...TESLA (TeV-Energy Superconducting Linear Collider) (will be) a superconducting electron-positron collider of initially 500 GeV total energy, extendable to 800 GeV, and an integrated X-ray laser laboratory.'' The TDR included cost and manpower estimates for a 500 GeV e{sup +}e{sup -} collider (250 on 250 GeV) based on superconducting RF cavity technology. This was submitted as a proposal to the German government. The government asked the German Science Council to evaluate this proposal. The recommendation from this body is anticipated to be available by November 2002. The government has indicated that it will react on this recommendation by mid-2003. In June 2001, Steve Holmes, Fermilab's Associate Director for Accelerators, commissioned Helen Edwards and Peter Garbincius to organize a study of the TESLA Technical Design Report and the associated cost and manpower estimates. Since the elements and methodology used in producing the TESLA cost estimate were somewhat different from those used in preparing similar estimates for projects within the U.S., it is important to understand the similarities, differences, and equivalences between the TESLA estimate and U.S. cost estimates. In particular, the project cost estimate includes only purchased equipment, materials, and services, but not manpower from DESY or other TESLA collaborating institutions, which is listed separately. It does not include the R&D on the TESLA Test Facility (TTF) nor the costs of preparing the TDR nor the costs of performing the conceptual studies so far. The manpower for the pre-operations commissioning program (up to beam) is included in the estimate, but not the electrical power or liquid Nitrogen (for initial cooldown of the cryogenics plant). There is no inclusion of any contingency or management reserve. If

  10. Report on the TESLA Engineering Study/Review

    International Nuclear Information System (INIS)

    Cornuelle, John C.

    2002-01-01

    In March, 2001, the TESLA Collaboration published its Technical Design Report (TDR, see references and links in Appendix), the first sentence of which stated ''...TESLA (TeV-Energy Superconducting Linear Collider) (will be) a superconducting electron-positron collider of initially 500 GeV total energy, extendable to 800 GeV, and an integrated X-ray laser laboratory.'' The TDR included cost and manpower estimates for a 500 GeV e + e - collider (250 on 250 GeV) based on superconducting RF cavity technology. This was submitted as a proposal to the German government. The government asked the German Science Council to evaluate this proposal. The recommendation from this body is anticipated to be available by November 2002. The government has indicated that it will react on this recommendation by mid-2003. In June 2001, Steve Holmes, Fermilab's Associate Director for Accelerators, commissioned Helen Edwards and Peter Garbincius to organize a study of the TESLA Technical Design Report and the associated cost and manpower estimates. Since the elements and methodology used in producing the TESLA cost estimate were somewhat different from those used in preparing similar estimates for projects within the U.S., it is important to understand the similarities, differences, and equivalences between the TESLA estimate and U.S. cost estimates. In particular, the project cost estimate includes only purchased equipment, materials, and services, but not manpower from DESY or other TESLA collaborating institutions, which is listed separately. It does not include the R and D on the TESLA Test Facility (TTF) nor the costs of preparing the TDR nor the costs of performing the conceptual studies so far. The manpower for the pre-operations commissioning program (up to beam) is included in the estimate, but not the electrical power or liquid Nitrogen (for initial cooldown of the cryogenics plant). There is no inclusion of any contingency or management reserve. If the U.S. were to become

  11. MR cholangio-pancreatography using an open, low magnetic field of 0.2 Tesla. Early clinical results and comparison with a higher magnetic field (1.5 Tesla) and with ERCP

    International Nuclear Information System (INIS)

    Wacker, Q.; Branding, G.; Wolf, K.J.; Zimmer, T.; Faiss, S.

    1997-01-01

    Aim: To evaluate MR cholangio-pancreatography (MRCP) using an open low magnetic field apparatus in normals and in patients with mechanical cholestasis. Methods: MRCP was performed on five normals and on 30 patients, using both an 0.2 Tesla and 1.5 Tesla apparatus. With the low field system, rapid acquisition by relaxation enhancement was used, for the high field system, half Fourier acquisition single shot turbo spin-echo sequences were used. In all patients, sonography and ERCP of PTC was performed; 23 underwent surgery. Results: In all normals it was possible to show the bile duct, hepatic duct, gall bladder and intrahepatic ducts of the first order. Using the high field system, second order ducts could be shown and sometimes third order ducts. In the patients, MRCP, using either system, demonstrated all 21 obstructive sites due to tumours or stenoses. Stones were shown in 69% by the low field system and in 88% by the high field system. Conclusion: MRCP can be successfully carried out using the low field system. In the presence of mechanical cholestasis, image quality is adequate for the localisation of stenoses and occlusions, and using an open magnet, is suitable for planning further intervention. (orig.) [de

  12. TESLA superconducting RF cavity development

    International Nuclear Information System (INIS)

    Koepke, K.

    1995-01-01

    The TESLA collaboration has made steady progress since its first official meeting at Cornell in 1990. The infrastructure necessary to assemble and test superconducting rf cavities has been installed at the TESLA Test Facility (TTF) at DESY. 5-cell, 1.3 GHz cavities have been fabricated and have reached accelerating fields of 25 MV/m. Full sized 9-cell copper cavities of TESLA geometry have been measured to verify the higher order modes present and to evaluate HOM coupling designs. The design of the TESLA 9-cell cavity has been finalized and industry has started delivery. Two prototype 9-cell niobium cavities in their first tests have reached accelerating fields of 10 MV/m and 15 MV/m in a vertical dewar after high peak power (HPP) conditioning. The first 12 m TESLA cryomodule that will house 8 9-cell cavities is scheduled to be delivered in Spring 1995. A design report for the TTF is in progress. The TTF test linac is scheduled to be commissioned in 1996/1997. (orig.)

  13. TESLA: Large Signal Simulation Code for Klystrons

    International Nuclear Information System (INIS)

    Vlasov, Alexander N.; Cooke, Simon J.; Chernin, David P.; Antonsen, Thomas M. Jr.; Nguyen, Khanh T.; Levush, Baruch

    2003-01-01

    TESLA (Telegraphist's Equations Solution for Linear Beam Amplifiers) is a new code designed to simulate linear beam vacuum electronic devices with cavities, such as klystrons, extended interaction klystrons, twistrons, and coupled cavity amplifiers. The model includes a self-consistent, nonlinear solution of the three-dimensional electron equations of motion and the solution of time-dependent field equations. The model differs from the conventional Particle in Cell approach in that the field spectrum is assumed to consist of a carrier frequency and its harmonics with slowly varying envelopes. Also, fields in the external cavities are modeled with circuit like equations and couple to fields in the beam region through boundary conditions on the beam tunnel wall. The model in TESLA is an extension of the model used in gyrotron code MAGY. The TESLA formulation has been extended to be capable to treat the multiple beam case, in which each beam is transported inside its own tunnel. The beams interact with each other as they pass through the gaps in their common cavities. The interaction is treated by modification of the boundary conditions on the wall of each tunnel to include the effect of adjacent beams as well as the fields excited in each cavity. The extended version of TESLA for the multiple beam case, TESLA-MB, has been developed for single processor machines, and can run on UNIX machines and on PC computers with a large memory (above 2GB). The TESLA-MB algorithm is currently being modified to simulate multiple beam klystrons on multiprocessor machines using the MPI (Message Passing Interface) environment. The code TESLA has been verified by comparison with MAGIC for single and multiple beam cases. The TESLA code and the MAGIC code predict the same power within 1% for a simple two cavity klystron design while the computational time for TESLA is orders of magnitude less than for MAGIC 2D. In addition, recently TESLA was used to model the L-6048 klystron, code

  14. MODERN ELECTRIC CARS OF TESLA MOTORS COMPANY

    OpenAIRE

    O. F. Vynakov; E. V. Savolova; A. I. Skrynnyk

    2016-01-01

    This overview article shows the advantages of a modern electric car as compared with internal combustion cars by the example of the electric vehicles of Tesla Motors Company. It (в смысле- статья) describes the history of this firm, provides technical and tactical characteristics of three modifications of electric vehicles produced by Tesla Motors. Modern electric cars are not less powerful than cars with combustion engines both in speed and acceleration amount. They are reliable, economical ...

  15. 3.0 Tesla magnetic resonance imaging: A new standard in liver imaging?

    Science.gov (United States)

    Girometti, Rossano

    2015-07-28

    An ever-increasing number of 3.0 Tesla (T) magnets are installed worldwide. Moving from the standard of 1.5 T to higher field strength implies a number of potential advantage and drawbacks, requiring careful optimization of imaging protocols or implementation of novel hardware components. Clinical practice and literature review suggest that state-of-the-art 3.0 T is equivalent to 1.5 T in the assessment of focal liver lesions and diffuse liver disease. Therefore, further technical improvements are needed in order to fully exploit the potential of higher field strength.

  16. 3.0 Tesla magnetic resonance imaging: A new standard in liver imaging?

    Science.gov (United States)

    Girometti, Rossano

    2015-01-01

    An ever-increasing number of 3.0 Tesla (T) magnets are installed worldwide. Moving from the standard of 1.5 T to higher field strength implies a number of potential advantage and drawbacks, requiring careful optimization of imaging protocols or implementation of novel hardware components. Clinical practice and literature review suggest that state-of-the-art 3.0 T is equivalent to 1.5 T in the assessment of focal liver lesions and diffuse liver disease. Therefore, further technical improvements are needed in order to fully exploit the potential of higher field strength. PMID:26244063

  17. A 0.5 Tesla Transverse-Field Alternating Magnetic Field Demagnetizer

    Science.gov (United States)

    Schillinger, W. E.; Morris, E. R.; Finn, D. R.; Coe, R. S.

    2015-12-01

    We have built an alternating field demagnetizer that can routinely achieve a maximum field of 0.5 Tesla. It uses an amorphous magnetic core with an air-cooled coil. We have started with a 0.5 T design, which satisfies most of our immediate needs, but we can certainly achieve higher fields. In our design, the magnetic field is transverse to the bore and uniform to 1% over a standard (25 mm) paleomagnetic sample. It is powered by a 1 kW power amplifier and is compatible with our existing sample handler for automated demagnetization and measurement (Morris et al., 2009). It's much higher peak field has enabled us to completely demagnetize many of the samples that previously we could not with commercial equipment. This capability is especially needed for high-coercivity sedimentary and igneous rocks that contain magnetic minerals that alter during thermal demagnetization. It will also enable detailed automated demagnetization of high coercivity phases in extraterrestrial samples, such as native iron, iron-alloy and sulfide minerals that are common in lunar rocks and meteorites. Furthermore, it has opened the door for us to use the rock-magnetic technique of component analysis, using coercivity distributions derived from very detailed AF demagnetization of NRM and remanence produced in the laboratory to characterize the magnetic mineralogy of sedimentary rocks. In addition to the many benefits this instrument has brought to our own research, a much broader potential impact is to replace the transverse coils in automated AF demagnetization systems, which typically are limited to peak fields around 0.1 T.

  18. Design and Fabrication Study on the TESLA500 Superconducting Magnet Package

    Energy Technology Data Exchange (ETDEWEB)

    Garcia-Tabares, L.; Toral, F.; Calero, J.; Abramian, P.; Iturbe, R.; Etxeandia, J.; Lucia, C.; Landete, R.; Gomez, J.

    2001-07-01

    An international collaboration at DESY is currently studying the possibilities of a new type of particle accelerator: the superconducting linear collider (1). Developed under the project name TESLA, which stands for TeV Energy Superconducting Linear Accelerator, the facility would be placed in a 33 km long tunnel and would work at the energy range of 0.5 to 0.8 TeV. TESLA opens up new horizons not only as a particle accelerator because it can be also used to generate laser-type X-ray beams: the accelerated electrons would be guided through a refined system of magnetic fields to form a Free Electron Laser (FEL). This study is about one of the components of the accelerator: the magnet package. A technical design of this device and a cost estimate of the series production have been performed. The present report should be understood as a Spanish contribution to the TESLA project. The study has been lead by CIEMAT (Centro de Investigaciones Energeticas, Medioambientales y Tecnologicas) [2], and several Spanish companies have also been involved: ANTEC, JEMA and INGOVI. Special thanks are given to the Oficina de Ciencia y Tecnologia, which has granted this work. (Author) 16 refs.

  19. Design and Fabrication Study on the TESLA500 Superconducting Magnet Package

    International Nuclear Information System (INIS)

    Garcia-Tabares, L.; Toral, F.; Calero, J.; Abramian, P.; Iturbe, R.; Etxeandia, J.; Lucia, C.; Landete, R.; Gomez, J.

    2001-01-01

    An international collaboration at DESY is currently studying the possibilities of a new type of particle accelerator: the superconducting linear collider (1). Developed under the project name TESLA, which stands for TeV Energy Superconducting Linear Accelerator, the facility would be placed in a 33 km long tunnel and would work at the energy range of 0.5 to 0.8 TeV. TESLA opens up new horizons not only as a particle accelerator because it can be also used to generate laser-type X-ray beams: the accelerated electrons would be guided through a refined system of magnetic fields to form a Free Electron Laser (FEL). This study is about one of the components of the accelerator: the magnet package. A technical design of this device and a cost estimate of the series production have been performed. The present report should be understood as a Spanish contribution to the TESLA project. The study has been lead by CIEMAT (Centro de Investigaciones Energeticas, Medioambientales y Tecnologicas) [2], and several Spanish companies have also been involved: ANTEC, JEMA and INGOVI. Special thanks are given to the Oficina de Ciencia y Tecnologia, which has granted this work. (Author) 16 refs

  20. [Nikola Tesla in medicine, too].

    Science.gov (United States)

    Hanzek, Branko; Jakobović, Zvonimir

    2007-12-01

    Using primary and secondary sources we have shown in this paper the influence of Nikola Tesla's work on the field of medicine. The description of his experiments conduced within secondary-school education programs aimed to present the popularization of his work in Croatia. Although Tesla was dedicated primarily to physics and was not directly involved in biomedical research, his work significantly contributed to paving the way of medical physics particularly radiology and high-frequency electrotherapy.

  1. Artefacts induced by coiled intracranial aneurysms on 3.0-Tesla versus 1.5-Tesla MR angiography—An in vivo and in vitro study

    Energy Technology Data Exchange (ETDEWEB)

    Schaafsma, Joanna D., E-mail: j.d.schaafsma@umcutrecht.nl [Department of Neurology, Rudolf Magnus Institute of Neuroscience, University Medical Centre, PO Box 85500, 3508 GA Utrecht (Netherlands); Velthuis, Birgitta K., E-mail: b.k.velthuis@umcutrecht.nl [Imaging Division, University Medical Centre, PO Box 85500, 3508 GA Utrecht (Netherlands); Vincken, Koen L., E-mail: koen@isi.uu.nl [Image Sciences Institute, University Medical Centre, PO Box 85500, 3508 GA Utrecht (Netherlands); Kort, Gerard A.P. de, E-mail: g.a.p.dekort@umcutrecht.nl [Imaging Division, University Medical Centre, PO Box 85500, 3508 GA Utrecht (Netherlands); Rinkel, Gabriel J.E., E-mail: g.j.e.rinkel@umcutrecht.nl [Department of Neurology, Rudolf Magnus Institute of Neuroscience, University Medical Centre, PO Box 85500, 3508 GA Utrecht (Netherlands); Bartels, Lambertus W., E-mail: w.bartels@umcutrecht.nl [Image Sciences Institute, University Medical Centre, PO Box 85500, 3508 GA Utrecht (Netherlands)

    2014-05-15

    Objective: To compare metal-induced artefacts from coiled intracranial aneurysms on 3.0-Tesla and 1.5-Tesla magnetic resonance angiography (MRA), since concerns persist on artefact enlargement at 3.0 Tesla. Materials and methods: We scanned 19 patients (mean age 53; 16 women) with 20 saccular aneurysms treated with coils only, at 1.5 and 3.0 Tesla according to standard clinical 3D TOF-MRA protocols containing a shorter echo-time but weaker read-out gradient at 3.0 Tesla in addition to intra-arterial digital subtraction angiography (IA-DSA). Per modality two neuro-radiologists assessed the occlusion status, measured residual flow, and indicated whether coil artefacts disturbed this assessment on MRA. We assessed relative risks for disturbance by coil artefacts, weighted kappa's for agreement on occlusion levels, and we compared remnant sizes. For artefact measurements, a coil model was created and scanned with the same protocols followed by 2D MR scans with variation of echo-time and read-out gradient strength. Results: Coil artefacts disturbed assessments less frequently at 3.0 Tesla than at 1.5 Tesla (RR: 0.3; 95%CI: 0.1–0.8). On 3.0-Tesla MRA, remnants were larger than on 1.5-Tesla MRA (difference: 0.7 mm; 95%CI: 0.3–1.1) and larger than on IA-DSA (difference: 1.0 mm; 95%CI: 0.6–1.5) with similar agreement on occlusion levels with IA-DSA for both field strengths (κ 0.53; 95%CI: 0.23–0.84 for 1.5-Tesla MRA and IA-DSA; κ 0.47; 95%CI: 0.19–0.76 for 3.0-Tesla MRA and IA-DSA). Coil model artefacts were smaller at 3.0 Tesla than at 1.5 Tesla. The echo-time influenced artefact size more than the read-out gradient. Conclusions: Artefacts were not larger, but smaller at 3.0 Tesla because a shorter echo-time at 3.0 Tesla negated artefact enlargement. Despite smaller artefacts and larger remnants at 3.0 Tesla, occlusion levels were similar for both field strengths.

  2. Artefacts induced by coiled intracranial aneurysms on 3.0-Tesla versus 1.5-Tesla MR angiography—An in vivo and in vitro study

    International Nuclear Information System (INIS)

    Schaafsma, Joanna D.; Velthuis, Birgitta K.; Vincken, Koen L.; Kort, Gerard A.P. de; Rinkel, Gabriel J.E.; Bartels, Lambertus W.

    2014-01-01

    Objective: To compare metal-induced artefacts from coiled intracranial aneurysms on 3.0-Tesla and 1.5-Tesla magnetic resonance angiography (MRA), since concerns persist on artefact enlargement at 3.0 Tesla. Materials and methods: We scanned 19 patients (mean age 53; 16 women) with 20 saccular aneurysms treated with coils only, at 1.5 and 3.0 Tesla according to standard clinical 3D TOF-MRA protocols containing a shorter echo-time but weaker read-out gradient at 3.0 Tesla in addition to intra-arterial digital subtraction angiography (IA-DSA). Per modality two neuro-radiologists assessed the occlusion status, measured residual flow, and indicated whether coil artefacts disturbed this assessment on MRA. We assessed relative risks for disturbance by coil artefacts, weighted kappa's for agreement on occlusion levels, and we compared remnant sizes. For artefact measurements, a coil model was created and scanned with the same protocols followed by 2D MR scans with variation of echo-time and read-out gradient strength. Results: Coil artefacts disturbed assessments less frequently at 3.0 Tesla than at 1.5 Tesla (RR: 0.3; 95%CI: 0.1–0.8). On 3.0-Tesla MRA, remnants were larger than on 1.5-Tesla MRA (difference: 0.7 mm; 95%CI: 0.3–1.1) and larger than on IA-DSA (difference: 1.0 mm; 95%CI: 0.6–1.5) with similar agreement on occlusion levels with IA-DSA for both field strengths (κ 0.53; 95%CI: 0.23–0.84 for 1.5-Tesla MRA and IA-DSA; κ 0.47; 95%CI: 0.19–0.76 for 3.0-Tesla MRA and IA-DSA). Coil model artefacts were smaller at 3.0 Tesla than at 1.5 Tesla. The echo-time influenced artefact size more than the read-out gradient. Conclusions: Artefacts were not larger, but smaller at 3.0 Tesla because a shorter echo-time at 3.0 Tesla negated artefact enlargement. Despite smaller artefacts and larger remnants at 3.0 Tesla, occlusion levels were similar for both field strengths

  3. Artefacts induced by coiled intracranial aneurysms on 3.0-Tesla versus 1.5-Tesla MR angiography--An in vivo and in vitro study.

    Science.gov (United States)

    Schaafsma, Joanna D; Velthuis, Birgitta K; Vincken, Koen L; de Kort, Gerard A P; Rinkel, Gabriel J E; Bartels, Lambertus W

    2014-05-01

    To compare metal-induced artefacts from coiled intracranial aneurysms on 3.0-Tesla and 1.5-Tesla magnetic resonance angiography (MRA), since concerns persist on artefact enlargement at 3.0Tesla. We scanned 19 patients (mean age 53; 16 women) with 20 saccular aneurysms treated with coils only, at 1.5 and 3.0Tesla according to standard clinical 3D TOF-MRA protocols containing a shorter echo-time but weaker read-out gradient at 3.0Tesla in addition to intra-arterial digital subtraction angiography (IA-DSA). Per modality two neuro-radiologists assessed the occlusion status, measured residual flow, and indicated whether coil artefacts disturbed this assessment on MRA. We assessed relative risks for disturbance by coil artefacts, weighted kappa's for agreement on occlusion levels, and we compared remnant sizes. For artefact measurements, a coil model was created and scanned with the same protocols followed by 2D MR scans with variation of echo-time and read-out gradient strength. Coil artefacts disturbed assessments less frequently at 3.0Tesla than at 1.5Tesla (RR: 0.3; 95%CI: 0.1-0.8). On 3.0-Tesla MRA, remnants were larger than on 1.5-Tesla MRA (difference: 0.7mm; 95%CI: 0.3-1.1) and larger than on IA-DSA (difference: 1.0mm; 95%CI: 0.6-1.5) with similar agreement on occlusion levels with IA-DSA for both field strengths (κ 0.53; 95%CI: 0.23-0.84 for 1.5-Tesla MRA and IA-DSA; κ 0.47; 95%CI: 0.19-0.76 for 3.0-Tesla MRA and IA-DSA). Coil model artefacts were smaller at 3.0Tesla than at 1.5Tesla. The echo-time influenced artefact size more than the read-out gradient. Artefacts were not larger, but smaller at 3.0Tesla because a shorter echo-time at 3.0Tesla negated artefact enlargement. Despite smaller artefacts and larger remnants at 3.0Tesla, occlusion levels were similar for both field strengths. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  4. Ultra high field magnetic resonance imaging

    International Nuclear Information System (INIS)

    Lethimonnier, F.; Vedrine, P.

    2007-01-01

    Understanding human brain function, brain development and brain dysfunction is one of the great challenges of the twenty first century. Biomedical imaging has now run up against a number of technical constraints that are exposing limits to its potential. In order to overcome the current limits to high-field magnetic resonance cerebral imaging (MRI) and unleash its fullest potential, the Cea has built NeuroSpin, an ultra-high-field neuroimaging facility at its Saclay centre (in the Essonne). NeuroSpin already boasts three fully operational MRI systems. The first is a 3-tesla high-field system and the second is a very-high-field 7-tesla system, both of which are dedicated to clinical studies and investigations in humans, while the third is an ultra-high-field 17.65-tesla system designed for studies on small animals. In 2011, NeuroSpin will be commissioning an 11.7-tesla ultra-high-field system of unprecedented power that is designed for research on human subjects. The level of the magnetic field and the scale required will make this joint French-German project to build the magnet a breakthrough in the international arena. (authors)

  5. Non-enhanced magnetic resonance imaging of the small bowel at 7 Tesla in comparison to 1.5 Tesla: First steps towards clinical application.

    Science.gov (United States)

    Hahnemann, Maria L; Kraff, Oliver; Maderwald, Stefan; Johst, Soeren; Orzada, Stephan; Umutlu, Lale; Ladd, Mark E; Quick, Harald H; Lauenstein, Thomas C

    2016-06-01

    To perform non-enhanced (NE) magnetic resonance imaging (MRI) of the small bowel at 7 Tesla (7T) and to compare it with 1.5 Tesla (1.5T). Twelve healthy subjects were prospectively examined using a 1.5T and 7T MRI system. Coronal and axial true fast imaging with steady-state precession (TrueFISP) imaging and a coronal T2-weighted (T2w) half-Fourier acquisition single-shot turbo spin-echo (HASTE) sequence were acquired. Image analysis was performed by 1) visual evaluation of tissue contrast and detail detectability, 2) measurement and calculation of contrast ratios and 3) assessment of artifacts. NE MRI of the small bowel at 7T was technically feasible. In the vast majority of the cases, tissue contrast and image details were equivalent at both field strengths. At 7T, two cases revealed better detail detectability in the TrueFISP, and better contrast in the HASTE. Susceptibility artifacts and B1 inhomogeneities were significantly increased at 7T. This study provides first insights into NE ultra-high field MRI of the small bowel and may be considered an important step towards high quality T2w abdominal imaging at 7T MRI. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Design of an 18 Tesla, tandem mirror, fusion reactor, hybrid choke coil

    International Nuclear Information System (INIS)

    Parmer, J.F.; Agarwal, K.; Gurol, H.; Mancuso, A.; Michels, P.H.; Peck, S.D.; Burgeson, J.; Dalder, E.N.

    1987-01-01

    A hybrid, part normal part superconducting 18-Tesla solenoid choke coil is designed for a tandem mirror fusion reactor. The present state of the art is represented by the 12-Tesla, superconducting NbSn coil. Future applications other than tandem mirror fusion devices needing high field solenoids might require hybrid magnets of the type described herein. The hybrid design was generated because of critical field performance limitations on present, practical superconducting wires. A hybrid design might be required (due to structural limits) even if the critical field were higher. Also, hybrids could be a cost-effective way of getting very high fields for certain applications. The 18-Tesla solenoid described is composed of an inner coil made of water-cooled, high-strength zirconium copper which generates 3 Tesla. A superconducting NbSn background coil contributes the remaining 15 Tesla. The focus of the design study was on the inner coil. Demonstration fabrication and testing was performed

  7. 1.5 versus 3 versus 7 Tesla in abdominal MRI: A comparative study.

    Science.gov (United States)

    Laader, Anja; Beiderwellen, Karsten; Kraff, Oliver; Maderwald, Stefan; Wrede, Karsten; Ladd, Mark E; Lauenstein, Thomas C; Forsting, Michael; Quick, Harald H; Nassenstein, Kai; Umutlu, Lale

    2017-01-01

    The aim of this study was to investigate and compare the feasibility as well as potential impact of altered magnetic field properties on image quality and potential artifacts of 1.5 Tesla, 3 Tesla and 7 Tesla non-enhanced abdominal MRI. Magnetic Resonance (MR) imaging of the upper abdomen was performed in 10 healthy volunteers on a 1.5 Tesla, a 3 Tesla and a 7 Tesla MR system. The study protocol comprised a (1) T1-weighted fat-saturated spoiled gradient-echo sequence (2D FLASH), (2) T1-weighted fat-saturated volumetric interpolated breath hold examination sequence (3D VIBE), (3) T1-weighted 2D in and opposed phase sequence, (4) True fast imaging with steady-state precession sequence (TrueFISP) and (5) T2-weighted turbo spin-echo (TSE) sequence. For comparison reasons field of view and acquisition times were kept comparable for each correlating sequence at all three field strengths, while trying to achieve the highest possible spatial resolution. Qualitative and quantitative analyses were tested for significant differences. While 1.5 and 3 Tesla MRI revealed comparable results in all assessed features and sequences, 7 Tesla MRI yielded considerable differences in T1 and T2 weighted imaging. Benefits of 7 Tesla MRI encompassed an increased higher spatial resolution and a non-enhanced hyperintense vessel signal at 7 Tesla, potentially offering a more accurate diagnosis of abdominal parenchymatous and vasculature disease. 7 Tesla MRI was also shown to be more impaired by artifacts, including residual B1 inhomogeneities, susceptibility and chemical shift artifacts, resulting in reduced overall image quality and overall image impairment ratings. While 1.5 and 3 Tesla T2w imaging showed equivalently high image quality, 7 Tesla revealed strong impairments in its diagnostic value. Our results demonstrate the feasibility and overall comparable imaging ability of T1-weighted 7 Tesla abdominal MRI towards 3 Tesla and 1.5 Tesla MRI, yielding a promising diagnostic potential for

  8. Beamstrahlung Photon Load on the TESLA Extraction Septum Blade(LCC-0104)

    Energy Technology Data Exchange (ETDEWEB)

    Seryi, A

    2003-10-02

    This note describes work performed in the framework of the International Linear Collider Technical Review Committee [1] to estimate the power load on the TESLA extraction septum blade due to beamstrahlung photons. It is shown, that under realistic conditions the photon load can be several orders of magnitude higher than what was estimated in the TESLA TDR [2] for the ideal Gaussian beams, potentially representing a serious limitation of the current design.

  9. Beamstrahlung Photon Load on the TESLA Extraction Septum Blade(LCC-0104)

    International Nuclear Information System (INIS)

    Seryi, A

    2003-01-01

    This note describes work performed in the framework of the International Linear Collider Technical Review Committee [1] to estimate the power load on the TESLA extraction septum blade due to beamstrahlung photons. It is shown, that under realistic conditions the photon load can be several orders of magnitude higher than what was estimated in the TESLA TDR [2] for the ideal Gaussian beams, potentially representing a serious limitation of the current design

  10. Non-Enhanced MR Imaging of Cerebral Arteriovenous Malformations at 7 Tesla.

    Science.gov (United States)

    Wrede, Karsten H; Dammann, Philipp; Johst, Sören; Mönninghoff, Christoph; Schlamann, Marc; Maderwald, Stefan; Sandalcioglu, I Erol; Ladd, Mark E; Forsting, Michael; Sure, Ulrich; Umutlu, Lale

    2016-03-01

    To evaluate prospectively 7 Tesla time-of-flight (TOF) magnetic resonance angiography (MRA) and 7 Tesla non-contrast-enhanced magnetization-prepared rapid acquisition gradient-echo (MPRAGE) for delineation of intracerebral arteriovenous malformations (AVMs) in comparison to 1.5 Tesla TOF MRA and digital subtraction angiography (DSA). Twenty patients with single or multifocal AVMs were enrolled in this trial. The study protocol comprised 1.5 and 7 Tesla TOF MRA and 7 Tesla non-contrast-enhanced MPRAGE sequences. All patients underwent an additional four-vessel 3D DSA. Image analysis of the following five AVM features was performed individually by two radiologists on a five-point scale: nidus, feeder(s), draining vein(s), relationship to adjacent vessels, and overall image quality and presence of artefacts. A total of 21 intracerebral AVMs were detected. Both sequences at 7 Tesla were rated superior over 1.5 Tesla TOF MRA in the assessment of all considered AVM features. Image quality at 7 Tesla was comparable with DSA considering both sequences. Inter-observer accordance was good to excellent for the majority of ratings. This study demonstrates excellent image quality for depiction of intracerebral AVMs using non-contrast-enhanced 7 Tesla MRA, comparable with DSA. Assessment of untreated AVMs is a promising clinical application of ultra-high-field MRA. • Non-contrast-enhanced 7 Tesla MRA demonstrates excellent image quality for intracerebral AVM depiction. • Image quality at 7 Tesla was comparable with DSA considering both sequences. • Assessment of intracerebral AVMs is a promising clinical application of ultra-high-field MRA.

  11. The Grenoble station for producing strong transient magnetic fields higher than 100 teslas by an explosive driven flux compression

    International Nuclear Information System (INIS)

    Guillot, M.

    1976-01-01

    Reproducible transient magnetic fields up to 400 teslas (4 megaoersted) are achieved by a simple explosive driven flux compression. The results are described simply from the point of view of energy conversion. The problems of field measurements are studied: the precision is +-2% with a field cavity of 5 mm diameter [fr

  12. Manual of Tesla Experiments; Handbuch Tesla Experimente

    Energy Technology Data Exchange (ETDEWEB)

    Wahl, Guenter

    2009-07-01

    The first part, ''Making Lightning and Thunder'', describes a number of Tesla generators that can generate, e.g., coloured light arcs, ball lightning and swords of lightning. The second part, ''New Experiments with EMP, Tesla Waves and Microwaves'', presents a solid state Tesla generator for generating electrodynamic vortices and proposes circuiting alternatives to generate electromagnetic pulses (EMP). Further, mysterious Teslar wave, microwave and scalar wave generators are presented, as well as exotic Star Wars experiments like mass accelerators and plasma guns. The third section describes, among others, a tube-driven Tesla generator with 50 cm streamers. The reader will also find a catalogue of Messrs. Information Unlimited, USA, who are providers of many of the kits, circuiting diagrams and apparatuses presented here. (orig.) [German] Der erste Teil mit dem Titel ''Blitz und Donner selbst erzeugt'' beschreibt eine Reihe von Teslageneratoren, mit denen zum Beispiel bunte Lichtbogen, Kugelblitze und Blitzschwerter erzeugt werden koennen. Im zweiten Teil ''Neue Experimente mit EMPs, Tesla- and Mikrowellen'' findet der Leser einen Solid-State-Teslagenerator zur Erzeugung elektrodynamischer Wirbel sowie Schaltungsvorschlaege zum Thema ''Elektromagnetischer Impuls'' (EMP). Des Weiteren werden geheimnisumwitterte Tesla-, Mikro- und Skalarwellengeneratoren vorgestellt. Exotische Star-Wars-Experimente wie Massenbeschleuniger und Plasmakanonen fehlen ebenfalls nicht. Im dritten Teil wird unter anderem ein roehrenbetriebener Teslagenerator mit Streamern von 50 cm Laenge beschrieben. Ausserdem findet der Leser hier einen Katalog der US-Firma Information Unlimited, bei der viele im Buch besprochenen Bausaetze, Schaltplaene und Fertiggeraete bezogen werden koennen. (orig.)

  13. Quantitative analysis of magnetic resonance imaging susceptibility artifacts caused by neurosurgical biomaterials. Comparison of 0.5, 1.5, and 3.0 tesla magnetic fields

    International Nuclear Information System (INIS)

    Matsuura, Hideki; Inoue, Takashi; Ogasawara, Kuniaki; Sasaki, Makoto; Konno, Hiromu; Kuzu, Yasutaka; Nishimoto, Hideaki; Ogawa, Akira

    2005-01-01

    Magnetic resonance (MR) imaging is an important diagnostic tool for neurosurgical diseases but susceptibility artifacts caused by biomaterial instrumentation frequently causes difficulty in visualizing postoperative changes. The susceptibility artifacts caused by neurosurgical biomaterials were compared quantitatively by 0.5, 1.5, and 3.0 Tesla MR imaging. MR imaging of uniform size and shape of pieces ceramic (zirconia), pure titanium, titanium alloy, and cobalt-based alloy was performed at 0.5, 1.5, and 3.0 Tesla. A linear region of interest was defined across the center of the biomaterial in the transverse direction, and the susceptibility artifact diameter was calculated. Susceptibility artifacts developed around all biomaterials at all magnetic field strengths. The artifact diameters caused by pure titanium, titanium alloy, and cobalt-based alloy increased in the order of 0.5, 1.5, to 3.0 Tesla magnetic fields. The artifact diameter of ceramic was not influenced by magnetic field strength, and was the smallest of all biomaterials at all magnetic field strengths. The artifacts caused by biomaterials except ceramic increase with the magnetic field strength. Ceramic instrumentation will minimize artifacts in all magnetic fields. (author)

  14. Tesla man out of time

    CERN Document Server

    Cheney, Margaret

    1981-01-01

    Called a madman by some, a genius by others, and an enigma by nearly everyone, Nikola Tesla created astonishing, world-transforming devises that were virtually without theoretical precedent. Tesla not only discovered the rotating magnetic field, the basis of most alternating current machinery, but also introduced the fundamentals of robotry, computers, and missile science and helped pave the way for such technologies as satellites, microwaves, beam weapons, and nuclear fusion. Almost supernaturally gifted, Tesla was also unusually erratic, flamboyant, and neurotic. He was J. P. Morgan's client, counted Mark Twain as a friend, and considered Thomas Edison an enemy. But above all, he was the hero and mentor to many of the last century's most famous scientists. In a meticulously researched, engagingly written biography, Margaret Cheney presents the many different dimensions of this extraordinary man, capturing his human qualities and quirks as she chronicles a lifetime of discoveries that continue to alter our ...

  15. Upgrading the power supplies of TEXTOR for three Tesla operation

    International Nuclear Information System (INIS)

    Giesen, B.; Veiders, E.; Petree, F.; Fink, R.; Wagnitz, R.

    1986-01-01

    The toroidal magnetic system of TEXTOR can tolerate a magnetic field load of up to 2.6 Tesla routinely at full plasma current, and of up to 3 Tesla under certain boundary conditions and for a restricted number of discharges. The original power supply which can generate a toroidal magnetic field of 2 Tesla has been upgraded to operate at a field strength of 3 Tesla, by adding a new, controlled rectifier, with its own independent control, connected in parallel with the first. Studies were undertaken to determine its behaviour where control is lost, such as when a circuit breaker trips or in ''freewheel'' operation. This paper analyzes this asymmetrical arrangement and discusses the danger of damaging the smaller unit by commutating a large current into it. Moreover, in order to improve the availability of TEXTOR, the new controlled rectifier is redundant to two other units that control the vertical field and the ohmic heating coil currents. For this purpose the two bridges of this 12-pulse system are to be changed from a parallel to a series connexion, the free-wheeling diodes are disconnected and redeployed to block the large voltage pulses that are induced at plasma initiation, and 3-phase ''freewheeling'' thyristors are added that serve to reduce reactive power consumption

  16. Micromechanical ``Trampoline'' Magnetometers for Use in Pulsed Magnetic Fields Exceeding 60 Tesla

    Science.gov (United States)

    Balakirev, F. F.; Boebinger, G. S.; Aksyuk, V.; Gammel, P. L.; Haddon, R. C.; Bishop, D. J.

    1998-03-01

    We present the design, construction, and operation of a novel magnetometer for use in intense pulsed magnetic fields. The magnetometer consists of a silicon micromachined "trampoline" to which the sample is attached. The small size of the device (typically 400 microns on a side) gives a fast mechanical response (10,000 to 50,000 Hz) and extremely high sensitivity (10-11 Am^2, corresponding to 10-13 Am^2/Hz^(1/2)). The device is robust against electrical and mechanical noise and requires no special vibration isolation from the pulsed magnet. As a demonstration, we present data taken in a 60 tesla pulsed magnetic field which show clear de Haas-van Alphen oscillations in a one microgram sample of the organic superconductor K-(BEDT-TTF)_2Cu(NCS)_2.

  17. Non-enhanced MR imaging of cerebral aneurysms: 7 Tesla versus 1.5 Tesla.

    Science.gov (United States)

    Wrede, Karsten H; Dammann, Philipp; Mönninghoff, Christoph; Johst, Sören; Maderwald, Stefan; Sandalcioglu, I Erol; Müller, Oliver; Özkan, Neriman; Ladd, Mark E; Forsting, Michael; Schlamann, Marc U; Sure, Ulrich; Umutlu, Lale

    2014-01-01

    To prospectively evaluate 7 Tesla time-of-flight (TOF) magnetic resonance angiography (MRA) in comparison to 1.5 Tesla TOF MRA and 7 Tesla non-contrast enhanced magnetization-prepared rapid acquisition gradient-echo (MPRAGE) for delineation of unruptured intracranial aneurysms (UIA). Sixteen neurosurgical patients (male n = 5, female n = 11) with single or multiple UIA were enrolled in this trial. All patients were accordingly examined at 7 Tesla and 1.5 Tesla MRI utilizing dedicated head coils. The following sequences were obtained: 7 Tesla TOF MRA, 1.5 Tesla TOF MRA and 7 Tesla non-contrast enhanced MPRAGE. Image analysis was performed by two radiologists with regard to delineation of aneurysm features (dome, neck, parent vessel), presence of artifacts, vessel-tissue-contrast and overall image quality. Interobserver accordance and intermethod comparisons were calculated by kappa coefficient and Lin's concordance correlation coefficient. A total of 20 intracranial aneurysms were detected in 16 patients, with two patients showing multiple aneurysms (n = 2, n = 4). Out of 20 intracranial aneurysms, 14 aneurysms were located in the anterior circulation and 6 aneurysms in the posterior circulation. 7 Tesla MPRAGE imaging was superior over 1.5 and 7 Tesla TOF MRA in the assessment of all considered aneurysm and image quality features (e.g. image quality: mean MPRAGE7T: 5.0; mean TOF7T: 4.3; mean TOF1.5T: 4.3). Ratings for 7 Tesla TOF MRA were equal or higher over 1.5 Tesla TOF MRA for all assessed features except for artifact delineation (mean TOF7T: 4.3; mean TOF1.5T 4.4). Interobserver accordance was good to excellent for most ratings. 7 Tesla MPRAGE imaging demonstrated its superiority in the detection and assessment of UIA as well as overall imaging features, offering excellent interobserver accordance and highest scores for all ratings. Hence, it may bear the potential to serve as a high-quality diagnostic tool for pretherapeutic assessment and

  18. Non-enhanced MR imaging of cerebral arteriovenous malformations at 7 Tesla

    International Nuclear Information System (INIS)

    Wrede, Karsten H.; Dammann, Philipp; Johst, Soeren; Maderwald, Stefan; Moenninghoff, Christoph; Forsting, Michael; Schlamann, Marc; Sandalcioglu, I.E.; Ladd, Mark E.; Sure, Ulrich; Umutlu, Lale

    2016-01-01

    To evaluate prospectively 7 Tesla time-of-flight (TOF) magnetic resonance angiography (MRA) and 7 Tesla non-contrast-enhanced magnetization-prepared rapid acquisition gradient-echo (MPRAGE) for delineation of intracerebral arteriovenous malformations (AVMs) in comparison to 1.5 Tesla TOF MRA and digital subtraction angiography (DSA). Twenty patients with single or multifocal AVMs were enrolled in this trial. The study protocol comprised 1.5 and 7 Tesla TOF MRA and 7 Tesla non-contrast-enhanced MPRAGE sequences. All patients underwent an additional four-vessel 3D DSA. Image analysis of the following five AVM features was performed individually by two radiologists on a five-point scale: nidus, feeder(s), draining vein(s), relationship to adjacent vessels, and overall image quality and presence of artefacts. A total of 21 intracerebral AVMs were detected. Both sequences at 7 Tesla were rated superior over 1.5 Tesla TOF MRA in the assessment of all considered AVM features. Image quality at 7 Tesla was comparable with DSA considering both sequences. Inter-observer accordance was good to excellent for the majority of ratings. This study demonstrates excellent image quality for depiction of intracerebral AVMs using non-contrast-enhanced 7 Tesla MRA, comparable with DSA. Assessment of untreated AVMs is a promising clinical application of ultra-high-field MRA. (orig.)

  19. Non-enhanced MR imaging of cerebral arteriovenous malformations at 7 Tesla

    Energy Technology Data Exchange (ETDEWEB)

    Wrede, Karsten H.; Dammann, Philipp [University Duisburg-Essen, Erwin L. Hahn Institute for Magnetic Resonance Imaging, Essen (Germany); University Hospital Essen, Department of Neurosurgery, Essen (Germany); Johst, Soeren; Maderwald, Stefan [University Duisburg-Essen, Erwin L. Hahn Institute for Magnetic Resonance Imaging, Essen (Germany); Moenninghoff, Christoph; Forsting, Michael [University Hospital Essen, Department of Diagnostic and Interventional Radiology and Neuroradiology, Essen (Germany); Schlamann, Marc [University Hospital Essen, Department of Diagnostic and Interventional Radiology and Neuroradiology, Essen (Germany); University Hospital Giessen, Department of Neuroradiology, Giessen (Germany); Sandalcioglu, I.E. [University Hospital Essen, Department of Neurosurgery, Essen (Germany); Nordstadtkrankenhaus Hannover, Department of Neurosurgery, Hannover (Germany); Ladd, Mark E. [University Duisburg-Essen, Erwin L. Hahn Institute for Magnetic Resonance Imaging, Essen (Germany); University Hospital Essen, Department of Diagnostic and Interventional Radiology and Neuroradiology, Essen (Germany); German Cancer Research Center (DKFZ), Division of Medical Physics in Radiology (E020), Heidelberg (Germany); Sure, Ulrich [University Hospital Essen, Department of Neurosurgery, Essen (Germany); Umutlu, Lale [University Duisburg-Essen, Erwin L. Hahn Institute for Magnetic Resonance Imaging, Essen (Germany); University Hospital Essen, Department of Diagnostic and Interventional Radiology and Neuroradiology, Essen (Germany)

    2016-03-15

    To evaluate prospectively 7 Tesla time-of-flight (TOF) magnetic resonance angiography (MRA) and 7 Tesla non-contrast-enhanced magnetization-prepared rapid acquisition gradient-echo (MPRAGE) for delineation of intracerebral arteriovenous malformations (AVMs) in comparison to 1.5 Tesla TOF MRA and digital subtraction angiography (DSA). Twenty patients with single or multifocal AVMs were enrolled in this trial. The study protocol comprised 1.5 and 7 Tesla TOF MRA and 7 Tesla non-contrast-enhanced MPRAGE sequences. All patients underwent an additional four-vessel 3D DSA. Image analysis of the following five AVM features was performed individually by two radiologists on a five-point scale: nidus, feeder(s), draining vein(s), relationship to adjacent vessels, and overall image quality and presence of artefacts. A total of 21 intracerebral AVMs were detected. Both sequences at 7 Tesla were rated superior over 1.5 Tesla TOF MRA in the assessment of all considered AVM features. Image quality at 7 Tesla was comparable with DSA considering both sequences. Inter-observer accordance was good to excellent for the majority of ratings. This study demonstrates excellent image quality for depiction of intracerebral AVMs using non-contrast-enhanced 7 Tesla MRA, comparable with DSA. Assessment of untreated AVMs is a promising clinical application of ultra-high-field MRA. (orig.)

  20. Construction of 0.15 Tesla Overhauser Enhanced MRI.

    Science.gov (United States)

    Tokunaga, Yuumi; Nakao, Motonao; Naganuma, Tatsuya; Ichikawa, Kazuhiro

    2017-01-01

    Overhauser enhanced MRI (OMRI) is one of the free radical imaging technologies and has been used in biomedical research such as for partial oxygen measurements in tumor, and redox status in acute oxidative diseases. The external magnetic field of OMRI is frequently in the range of 5-10 mTesla to ensure microwave penetration into small animals, and the S/N ratio is limited. In this study, a 0.15 Tesla OMRI was constructed and tested to improve the S/N ratio for a small sample, or skin measurement. Specification of the main magnet was as follows: 0.15 Tesla permanent magnet; gap size 160 mm; homogenous spherical volume of 80 mm in diameter. The OMRI resonator was designed based on TE 101 cavity mode and machined from a phosphorus deoxidized copper block for electron spin resonance (ESR) excitation and a solenoid transmission/receive resonator for NMR detection. The resonant frequencies and Q values were 6.38 MHz/150 and 4.31-4.41 GHz/120 for NMR and ESR, respectively. The Q values were comparable to those of conventional low field OMRI resonators at 15 mTesla. As expected, the MRI S/N ratio was improved by a factor of 30. Triplet dynamic nuclear polarization spectra were observed for 14 N carboxy-PROXYL, along the excitation microwave sweep. In the current setup, the enhancement factor was ca. 0.5. In conclusion, the results of this preliminary evaluation indicate that the 0.15 Tesla OMRI could be useful for free radical measurement for small samples.

  1. Collimation system for the VUV free-electron laser at the TESLA test facility

    International Nuclear Information System (INIS)

    Schlarb, H.

    2001-11-01

    To perform a proof-of-principle experiment for a Free Electron Laser operating at VUV wavelengths an undulator has been installed in the TESLA Test Facility linac phase I. To meet the requirements on the magnetic field quality in the undulator, a hybrid type structure with NdFeB permanent magnets has been chosen. The permanent magnets are sensitive to radiation by high energy particles. In order to perform the various experiments planned at the TESLA Test Facility linac, a collimator section has been installed to protect the undulator from radiation. In this thesis the design, performance and required steps for commissioning the collimator system are presented. To identify potential difficulties for the linac operation, the beam halo and the dark current transport through the entire linac is discussed. Losses of primary electrons caused by technical failures, component misalignments, and operation errors are investigated by tracking simulations, in order to derive a complete understanding of the absorbed dose in the permanent magnets of the undulator. Various topics related to a collimator system such as the removal of secondary particles produced at the collimators, generation and shielding of neutrons, excitation of wake fields, and beam based alignment concepts are important subjects of this thesis. (orig.)

  2. Novel techniques for 7 tesla breast MRI

    NARCIS (Netherlands)

    van der Velden, T.A.

    2017-01-01

    This thesis introduced several new techniques to the field of 7 tesla breast MRI, enabling high field multi-parametric MR imaging and, potentially, patient specific treatment planning. Chapter 2 described the development of a RF coil setup for bilateral breast MR imaging and 31P spectroscopy. This

  3. Energy Spread Sources in TESLA and TTF

    International Nuclear Information System (INIS)

    Mosnier, A.; Tessier, J.M.

    1995-03-01

    The beam energy spread in the TESLA linac must be small enough to limit the emittance dilution due to the dispersive effects. This report summarizes the major sources of energy spread both for the TESLA linac and the TTF linac, where these estimations will be carefully checked with beam experiments. The first part recalls the intra-bunch energy spread while the second part looks into the bunch-to-bunch energy spread induced by rf field fluctuations within the bunch train and from pulse-to-pulse. (author). 3 refs., 4 figs

  4. Magnetic resonance examinations at two Tesla

    International Nuclear Information System (INIS)

    Grabbe, E.; Maas, R.; Heller, M.; Denkhaus, H.; Buecheler, E.

    1986-01-01

    After having used a 2 Tesla prototype whole body scanner for about one and a half years, it is now possible to comment on the clinical value of high field strengths. The methods and techniques employed are described. The problems arising from high field strengths are discussed and their effect on clinical diagnosis is indicated. (orig.) [de

  5. Proposed applications with implementation techniques of the upcoming renewable energy resource, The Tesla Turbine

    International Nuclear Information System (INIS)

    Khan, M Usman Saeed; Maqsood, M Irfan; Ali, Ehsan; Jamal, Shah; Javed, M

    2013-01-01

    Recent research has shown that tesla turbine can be one of the future efficient sources of renewable energy. Modern techniques used for designing of tesla turbine have given optimum results regarding efficiency and applications. In this paper we have suggested fully coordinated applications of tesla turbine in different fields particularly in power generation at both low level and high level generation. In Energy deficient countries the tesla turbine has wide range of applications and it can play an important role in energy management system. Our proposed applications includes, - the use of tesla turbine as renewable energy resource; - using tesla turbine in distributed generation system; - use of tesla turbine at home for power generation; - use of tesla turbine in irrigation channels; - using tesla turbine in hybrid electric vehicles; All applications are explained with the help of flow charts and block diagrams and their implementation techniques are also explained in details. The results of physical experiments and simulations are also included for some applications.

  6. Conceptual design of a 20 Tesla pulsed solenoid for a laser solenoid fusion reactor

    International Nuclear Information System (INIS)

    Nolan, J.J.; Averill, R.J.

    1977-01-01

    Design considerations are described for a strip wound solenoid which is pulsed to 20 tesla while immersed in a 20 tesla bias field so as to achieve within the bore of the pulsed solenoid at net field sequence starting at 20 tesla and going first down to zero, then up to 40 tesla, and finally back to 20 tesla in a period of about 5 x 10 -3 seconds. The important parameters of the solenoid, e.g., aperture, build, turns, stored and dissipated energy, field intensity and powering circuit, are given. A numerical example for a specific design is presented. Mechanical stresses in the solenoid and the subsequent choice of materials for coil construction are discussed. Although several possible design difficulties are not discussed in this preliminary report of a conceptual magnet design, such as uniformity of field, long-term stability of insulation under neutron bombardment and choice of structural materials of appropriate tensile strength and elasticity to withstand magnetic forces developed, these questions are addressed in detail in the complete design report and in part in reference one. Furthermore, the authors feel that the problems encountered in this conceptual design are surmountable and are not a hindrance to the construction of such a magnet system

  7. Low frequency AC losses in multi filamentary superconductors up to 15 Tesla

    International Nuclear Information System (INIS)

    Orlando, T.; Braun, C.; Foner, S.; Schwartz, B.; Zieba, A.

    1983-01-01

    Low frequency (1 Hz) ac losses were measured in a variety of A15 superconducting wires having different fiber geometries. Field modulations ofless than or equal to 1 tesla were superimposed on a fixed background field up to 15 tesla. Losses were measured for Nb 3 Sn in continuous fiber, modified jelly-roll, In Situ, and powder metallurgy processed materials, and for Nb 3 Al powder metallurgy processed materials. The results are compared with dc magnetization measurements. The losses are purely hysteretic at these low frequencies, scale with J /SUB c/ (above about 3 tesla), and are reduced substantially by twisting for all the materials. The lowest losses are observed for the Nb 3 Al wires

  8. D-zero rototrack: first stage of D-zero 2 Tesla solenoid field mapping device

    International Nuclear Information System (INIS)

    Yamada, R.; Korienek, J.; Krider, J.; Lindenmeyer, C.; Miksa, D.; Miksa, R.

    1997-09-01

    A simple and portable field mapping device was developed at Fermilab and successfully used to test the D0 2 Tesla solenoid at Toshiba Works in Japan. A description of the mechanical structure, electric driving and control system, and software of the field mapping device is given. Four Hall probe elements of Group3 Digital Gaussmeters are mounted on the radial extension arm of a carriage, which is mounted on a central rotating beam. The system gives two dimensional motions (axial and rotational) to the Hall probes. To make the system compact and portable, we used a laptop computer with PCMCIA cards. For the control system we used commercially available software LabVIEW and Motion Toolbox, and for the data analysis we used Microsoft Excel

  9. MODERN ELECTRIC CARS OF TESLA MOTORS COMPANY

    Directory of Open Access Journals (Sweden)

    O. F. Vynakov

    2016-08-01

    Full Text Available This overview article shows the advantages of a modern electric car as compared with internal combustion cars by the example of the electric vehicles of Tesla Motors Company. It (в смысле- статья describes the history of this firm, provides technical and tactical characteristics of three modifications of electric vehicles produced by Tesla Motors. Modern electric cars are not less powerful than cars with combustion engines both in speed and acceleration amount. They are reliable, economical and safe in operation. With every year the maximum range of an electric car is increasing and its battery charging time is decreasing.Solving the problem of environmental safety, the governments of most countries are trying to encourage people to switch to electric cars by creating subsidy programs, lending and abolition of taxation. Therefore, the advent of an electric vehicle in all major cities of the world is inevitable.

  10. Nell’anno di Nikola Tesla

    Directory of Open Access Journals (Sweden)

    Persida Lazarević Di Giacomo

    2006-12-01

    Full Text Available The 150th Anniversary Celebration of Nikola Tesla The paper deals with the 150th anniversary celebration of Nikola Tesla, the greatest ever Yugoslav scientist. Due to his origins, Tesla is contended between Serbia and Croatia, but he is also considered to be an American scientist since he registered most of his patents in the USA. Although there is some dissension between Serbia and Croatia regarding the historical facts about Tesla’s life, it can be asserted that Tesla appears to be an example of collaboration among the former Yugoslav countries. Tesla, however, deserves to be remembered as well as the author of autobiographical prose (My Inventions; Some Personal Recollections; A Strange Experience by Nikola Tesla and as the protagonist of many works published in Serbo-Croatian and in English, such as Miloš Crnjanski’s drama Tesla (1969 or The Hunger and Ecstasy of Vampires (1996 by Brian M. Stableford, for example. This fact should not be neglected and actually should be researched more fully.

  11. [70 years of Nikola Tesla studies].

    Science.gov (United States)

    Juznic, Stanislav

    2013-01-01

    Nikola Tesla's studies of chemistry are described including his not very scholarly affair in Maribor. After almost a century and half of hypothesis at least usable scenario of Tesla's life and "work" in Maribor is provided. The chemistry achievements of Tesla's most influential professors Martin Sekulić and Tesla's Graz professors are put into the limelight. The fact that Tesla in Graz studied on the technological chemistry Faculty of Polytechnic is focused.

  12. The TESLA RF System

    International Nuclear Information System (INIS)

    Choroba, S.

    2003-01-01

    The TESLA project proposed by the TESLA collaboration in 2001 is a 500 to 800GeV e+/e- linear collider with integrated free electron laser facility. The accelerator is based on superconducting cavity technology. Approximately 20000 superconducting cavities operated at 1.3GHz with a gradient of 23.4MV/m or 35MV/m will be required to achieve the energy of 500GeV or 800GeV respectively. For 500GeV ∼600 RF stations each generating 10MW of RF power at 1.3GHz at a pulse duration of 1.37ms and a repetition rate of 5 or 10Hz are required. The original TESLA design was modified in 2002 and now includes a dedicated 20GeV electron accelerator in a separate tunnel for free electron laser application. The TESLA XFEL will provide XFEL radiation of unprecedented peak brilliance and full transverse coherence in the wavelength range of 0.1 to 6.4nm at a pulse duration of 100fs. The technology of both accelerators, the TESLA linear collider and the XFEL, will be identical, however the number of superconducting cavities and RF stations for the XFEL will be reduced to 936 and 26 respectively. This paper describes the layout of the entire RF system of the TESLA linear collider and the TESLA XFEL and gives an overview of its various subsystems and components

  13. Improving heat generation of magnetic nanoparticles by pre-orientation of particles in a static three tesla magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Beck, Mathias M., E-mail: Mathias.Beck@tum.de [Institute for Machine Tools and Industrial Management, Technical University of Munich, Boltzmannstr. 15, 85748 Garching (Germany); Lammel, Christian [Institute for Machine Tools and Industrial Management, Technical University of Munich, Boltzmannstr. 15, 85748 Garching (Germany); Gleich, Bernhard [Institute of Medical Engineering, Technical University of Munich, Boltzmannstr. 11, 85748 Garching (Germany)

    2017-04-01

    Inductive heating of electrically insulating materials like fiberglass reinforced thermoplastics (FRTP) without susceptors is not possible. However, due to their low thermal conductivity a volumetric heat generation method is advisable to reach short heating times to melt this material for reshaping. This can be done with magnetic nanoparticles as susceptors within the thermoplastic of the FRTP using Néel relaxation. During the heating process the particle's magnetic moment rotates with the field while the particle itself is fixed within the thermoplastic. Therefore the heat dissipation of each particle depends on its orientation within the field. To achieve the maximum heat generation of the particles we pre-oriented the particles within a plastic at the best angle to the applied AC field for induction. To do this, five mass percent nanoparticles were dispersed in an epoxy resin, which was then hardened at room temperature in a static three Tesla magnetic field. After its solidification the heating behavior of the sample was compared to a reference sample, which was hardened without a field. The oriented particles showed an increased heating rate when oriented parallel to the applied AC field. The absorption rate was 3.3 times as high as the undirected reference sample. When the alternating electromagnetic field was perpendicular to the oriented particles, the specific absorption rate was similar to that of the reference sample. We compare this result with theory and with calculations from literature, and conduct a numerical simulation. - Highlights: • Magnetic nanoparticles are aligned using a static three tesla magnetic field. • Inductive heating depends on the particles pre-orientation in a solid matrix. • Alignment increases the heat generation significantly.

  14. TESLA & ILC Cryomodules

    Energy Technology Data Exchange (ETDEWEB)

    Peterson, T. J. [Fermi National Accelerator Laboratory (FNAL), Batavia, IL (United States); Weisend, II, J. G. [Fermi National Accelerator Laboratory (FNAL), Batavia, IL (United States)

    2016-01-01

    The TESLA collaboration developed a unique variant of SRF cryomodule designs, the chief feature being use of the large, low pressure helium vapor return pipe as the structural support backbone of the cryomodule. Additional innovative features include all cryogenic piping within the cryomodule (no parallel external cryogenic transfer line), long strings of RF cavities within a single cryomodule, and cryomodules connected in series. Several projects, including FLASH and XFEL at DESY, LCLS-II at SLAC, and the ILC technical design have adopted this general design concept. Advantages include saving space by eliminating the external transfer line, relatively tight packing of RF cavities along the beamline due to fewer warm-cold transitions, and potentially lower costs. However, a primary disadvantage is the relative lack of independence for warm-up, replacement, and cool-down of individual cryomodules.

  15. Nell’anno di Nikola Tesla

    OpenAIRE

    Persida Lazarević Di Giacomo

    2006-01-01

    The 150th Anniversary Celebration of Nikola Tesla The paper deals with the 150th anniversary celebration of Nikola Tesla, the greatest ever Yugoslav scientist. Due to his origins, Tesla is contended between Serbia and Croatia, but he is also considered to be an American scientist since he registered most of his patents in the USA. Although there is some dissension between Serbia and Croatia regarding the historical facts about Tesla’s life, it can be asserted that Tesla appears to be an...

  16. Linear Colliders TESLA

    International Nuclear Information System (INIS)

    Anon.

    1994-01-01

    The aim of the TESLA (TeV Superconducting Linear Accelerator) collaboration (at present 19 institutions from seven countries) is to establish the technology for a high energy electron-positron linear collider using superconducting radiofrequency cavities to accelerate its beams. Another basic goal is to demonstrate that such a collider can meet its performance goals in a cost effective manner. For this the TESLA collaboration is preparing a 500 MeV superconducting linear test accelerator at the DESY Laboratory in Hamburg. This TTF (TESLA Test Facility) consists of four cryomodules, each approximately 12 m long and containing eight 9-cell solid niobium cavities operating at a frequency of 1.3 GHz

  17. Neurobehavioral effects among subjects exposed to high static and gradient magnetic fields from a 1.5 Tesla magnetic resonance imaging system--a case-crossover pilot study.

    Science.gov (United States)

    de Vocht, Frank; van-Wendel-de-Joode, Berna; Engels, Hans; Kromhout, Hans

    2003-10-01

    The interactive use of magnetic resonance imaging (MRI) techniques is increasing in operating theaters. A study was performed on 17 male company volunteers to assess the neurobehavioral effects of exposure to magnetic fields from a 1.5 Tesla MRI system. The subjects' neurobehavioral performances on a neurobehavioral test battery were compared in four 1-hr sessions with and without exposure to magnetic fields, and with and without additional movements. Adverse effects were found for hand coordination (-4%, P Tesla MRI system may lead to neurobehavioral effects. Further research is recommended, especially in members of operating teams using interactive MRI systems. Copyright 2003 Wiley-Liss, Inc.

  18. Technical Assessment of Artifact Production from Neuro Endovascular Coil At 3 Tesla MRI: An In Vitro Study

    International Nuclear Information System (INIS)

    Kampaengtip, A.; Krisanachinda, A.; Singhara Na Ayudya, S.; Asavaphatiboon, S.

    2012-01-01

    Introduction: Magnetic resonance imaging (MRI) is an essential part of the diagnostic procedures in radiology. MRI 3 Tesla becomes more widespread due to high signal to noise ratio (SNR). The use of the neuro endovascular coil to overcome the neuro aneurysm can introduce the artifact in magnetic resonance imaging. Susceptibility artifacts and geometric distortions caused by magnetic field inhomogeneity- related signal loss is used to refer to an artifact in magnetic resonance images. It consists of a region of signal void with a surrounding area of an increased signal intensity that appears to be considerably larger than the actual size of the device causing the artifact. The objective of the study is to compare the size of the artifact on the MR image to the actual size of endovascular coils using a 3 Tesla magnetic resonance imaging system, in vitro study. Methods: The endovascular coils were made from detachable platinum and aneurysm models were constructed by using silicone tube. MRI 3 Tesla Philips Model Achieva with pulse sequence selections were: spin echo, fast spin echo, inversion recovery, fast gradient echo while additional parameters were echo time and turbo factor. Results: Improved visualization of perianeurysmal soft tissues is best accomplished by spin echo for fast spin echo sequences, even better suited to reduce metal artifact. Furthermore, shorter turbo factor and shorter effective TE in the latter sequences are beneficial for the same reason as sequences having shorter TE. Sequences with a shorter TE are preferred because of less time for dephasing and frequency shifting. Imaging at gradient echo series increases susceptibility artifacts. In this in vitro study, some of the major characteristics related to MRI imaging of coil packs have been defined. Discussion: Pulse sequence spin echo is the best sequence reducing the susceptibility artifact. Reducing the TE is the main factor in improving endovascular coil visualization on MRI images. The

  19. Experimental program with beam in TESLA test facility

    International Nuclear Information System (INIS)

    Mosnier, A.; Aune, B.

    1994-09-01

    In order to establish a technical basis for a high energy e + e - collider using the superconducting RF technology, the test of a string of 32 cavities with beam at an accelerating gradient of 15 MV/m is planned in an installation at DESY. Several experiments with beam in the TTF linac will be performed. The dissipated HOM power at helium temperature is a key issue for TESLA, its estimation requires careful calorimetric measurements and the full charge injector. Bunch wake potentials can be estimated with bunch charges of at least 1 to 2 nC. Multibunch measurements require a beam of a few hundreds of these bunches. The beam will be injected either on axis or off axis. RF steering due to couplers will be estimated by measuring the beam displacement for different RF phase settings. The expected resolution is well below the TESLA specification. The acceleration of dark currents will be observed for different settings of the focusing elements. 7 figs., 1 tab., 3 refs

  20. k-t SENSE-accelerated Myocardial Perfusion MR Imaging at 3.0 Tesla - comparison with 1.5 Tesla

    Science.gov (United States)

    Plein, Sven; Schwitter, Juerg; Suerder, Daniel; Greenwood, John P.; Boesiger, Peter; Kozerke, Sebastian

    2008-01-01

    Purpose To determine the feasibility and diagnostic accuracy of high spatial resolution myocardial perfusion MR at 3.0 Tesla using k-space and time domain undersampling with sensitivity encoding (k-t SENSE). Materials and Methods The study was reviewed and approved by the local ethic review board. k-t SENSE perfusion MR was performed at 1.5 Tesla and 3.0 Tesla (saturation recovery gradient echo pulse sequence, repetition time/echo time 3.0ms/1.0ms, flip angle 15°, 5x k-t SENSE acceleration, spatial resolution 1.3×1.3×10mm3). Fourteen volunteers were studied at rest and 37 patients during adenosine stress. In volunteers, comparison was also made with standard-resolution (2.5×2.5×10mm3) 2x SENSE perfusion MR at 3.0 Tesla. Image quality, artifact scores, signal-to-noise ratios (SNR) and contrast-enhancement ratios (CER) were derived. In patients, diagnostic accuracy of visual analysis to detect >50% diameter stenosis on quantitative coronary angiography was determined by receiver-operator-characteristics (ROC). Results In volunteers, image quality and artifact scores were similar for 3.0 Tesla and 1.5 Tesla, while SNR was higher (11.6 vs. 5.6) and CER lower (1.1 vs. 1.5, p=0.012) at 3.0 Tesla. Compared with standard-resolution perfusion MR, image quality was higher for k-t SENSE (3.6 vs. 3.1, p=0.04), endocardial dark rim artifacts were reduced (artifact thickness 1.6mm vs. 2.4mm, pTesla and 1.5 Tesla, respectively. Conclusions k-t SENSE accelerated high-resolution perfusion MR at 3.0 Tesla is feasible with similar artifacts and diagnostic accuracy as at 1.5 Tesla. Compared with standard-resolution perfusion MR, image quality is improved and artifacts are reduced. PMID:18936311

  1. Cryogenic system for the 45 Tesla hybrid magnet

    International Nuclear Information System (INIS)

    Van Sciver, S.W.; Miller, J.R.; Welton, S.; Schneider-Muntau, H.J.; McIntosh, G.E.

    1994-01-01

    The 45 Tesla hybrid magnet system will consist of a 14 Tesla superconducting outsert magnet and a 31 Tesla water cooled insert. The magnet is planned for operation in early 1995 at the National High Magnetic Field Laboratory. Its purpose is to provide the highest DC magnetic fields for the materials research community. The present paper discusses the overall design of the cryogenic system for the superconducting magnet. Unique features of this system include static 1.8 K pressurized He II as a coolant for the magnet and a refrigerated structural support system for load transfer during fault conditions. The system will consist of two connected cryostats. The magnet is contained within one cryostat which has a clear warm bore of 616 mm and is designed to be free of system interfaces and therefore minimize interference with the magnet user. A second supply cryostat provides the connections to the refrigeration system and magnet power supply. The magnet and supply cryostats are connected to each other through a horizontal services duct section. Issues to be discussed in the present paper include design and thermal analysis of the magnet system during cooldown and in steady state operation and overall cryogenic system design

  2. Two-Layer 16 Tesla Cosθ Dipole Design for the FCC

    Energy Technology Data Exchange (ETDEWEB)

    Holik, Eddie Frank [Fermilab; Ambrosio, Giorgio [Fermilab; Apollinari, G. [Fermilab

    2018-02-13

    The Future Circular Collider or FCC is a study aimed at exploring the possibility to reach 100 TeV total collision energy which would require 16 tesla dipoles. Upon the conclusion of the High Luminosity Upgrade, the US LHC Accelerator Upgrade Pro-ject in collaboration with CERN will have extensive Nb3Sn magnet fabrication experience. This experience includes robust Nb3Sn conductor and insulation scheming, 2-layer cos2θ coil fabrication, and bladder-and-key structure and assembly. By making im-provements and modification to existing technology the feasibility of a two-layer 16 tesla dipole is investigated. Preliminary designs indicate that fields up to 16.6 tesla are feasible with conductor grading while satisfying the HE-LHC and FCC specifications. Key challenges include accommodating high-aspect ratio conductor, narrow wedge design, Nb3Sn conductor grading, and especially quench protection of a 16 tesla device.

  3. Structural analysis of TFTR TF coils and support structure for 6 Tesla operation

    International Nuclear Information System (INIS)

    Zatz, I.J.; Cargulia, G.; Lontai, L.

    1995-01-01

    The Tokamak Fusion Test Reactor (TFTR), which has been on line since December 1982, has successfully operated at its design Toroidal Field (TF) of 5.2 Tesla. Analysis of test data has indicated that the measured peak D-D neutron power in supershots may be scaled to the fourth power of TF field. Increasing the TF field to 6 Tesla provides the opportunity to explore the possibility of improving the D-T fusion yield, with the use of tritium. This increase in TF field from 5.2 to 6.0 Tesla increases the centering force by 33% and the out-of-plane force by 15% over previous peak operating levels. To examine the impact of the increase in loads on the TF coil, case and supporting structure, finite element analyses (FEA) were performed with and without the presence of loose bolts in the TF case. Note that the loose bolts comprise a fraction of the total number of bolts fastening the TF case sidewalls to the inner and outer rings of the case. Extensive analysis was performed using the FEA results in conjunction with supplementary calculations. Results are presented for the TF case, bolts, copper conductors, insulation, and supporting structure which indicate that the TF coils can successfully operate at 6 Tesla for a reasonable number of pulses

  4. TESLA project goes public

    International Nuclear Information System (INIS)

    Flegel', I.

    2002-01-01

    The TESLA project connected with the creation of superconducting linear accelerator with colliding neutron and positron beams in the DESY Laboratory (Hamburg) is presented. Scientists of 36 countries make a contribution in the Feasibility study of new accelerator construction. Creation of new accelerator will open the way to the investigation into new elementary particles; TESLA is perfectly suitable for the production of Higgs particles. Exact measurements on the unit will allow to research into properties of supersymmetrical particles. The TESLA project involves the creation of X-ray free electron laser [ru

  5. Direct measurement of kilo-tesla level magnetic field generated with laser-driven capacitor-coil target by proton deflectometry

    Science.gov (United States)

    Law, K. F. F.; Bailly-Grandvaux, M.; Morace, A.; Sakata, S.; Matsuo, K.; Kojima, S.; Lee, S.; Vaisseau, X.; Arikawa, Y.; Yogo, A.; Kondo, K.; Zhang, Z.; Bellei, C.; Santos, J. J.; Fujioka, S.; Azechi, H.

    2016-02-01

    A kilo-tesla level, quasi-static magnetic field (B-field), which is generated with an intense laser-driven capacitor-coil target, was measured by proton deflectometry with a proper plasma shielding. Proton deflectometry is a direct and reliable method to diagnose strong, mm3-scale laser-produced B-field; however, this was not successful in the previous experiment. A target-normal-sheath-accelerated proton beam is deflected by Lorentz force in the laser-produced magnetic field with the resulting deflection pattern recorded on a radiochromic film stack. A 610 ± 30 T of B-field amplitude was inferred by comparing the experimental proton pattern with Monte-Carlo calculations. The amplitude and temporal evolutions of the laser-generated B-field were also measured by a differential magnetic probe, independently confirming the proton deflectometry measurement results.

  6. Repeatability of Brain Volume Measurements Made with the Atlas-based Method from T1-weighted Images Acquired Using a 0.4 Tesla Low Field MR Scanner.

    Science.gov (United States)

    Goto, Masami; Suzuki, Makoto; Mizukami, Shinya; Abe, Osamu; Aoki, Shigeki; Miyati, Tosiaki; Fukuda, Michinari; Gomi, Tsutomu; Takeda, Tohoru

    2016-10-11

    An understanding of the repeatability of measured results is important for both the atlas-based and voxel-based morphometry (VBM) methods of magnetic resonance (MR) brain volumetry. However, many recent studies that have investigated the repeatability of brain volume measurements have been performed using static magnetic fields of 1-4 tesla, and no study has used a low-strength static magnetic field. The aim of this study was to investigate the repeatability of measured volumes using the atlas-based method and a low-strength static magnetic field (0.4 tesla). Ten healthy volunteers participated in this study. Using a 0.4 tesla magnetic resonance imaging (MRI) scanner and a quadrature head coil, three-dimensional T 1 -weighted images (3D-T 1 WIs) were obtained from each subject, twice on the same day. VBM8 software was used to construct segmented normalized images [gray matter (GM), white matter (WM), and cerebrospinal fluid (CSF) images]. The regions-of-interest (ROIs) of GM, WM, CSF, hippocampus (HC), orbital gyrus (OG), and cerebellum posterior lobe (CPL) were generated using WFU PickAtlas. The percentage change was defined as[100 × (measured volume with first segmented image - mean volume in each subject)/(mean volume in each subject)]The average percentage change was calculated as the percentage change in the 6 ROIs of the 10 subjects. The mean of the average percentage changes for each ROI was as follows: GM, 0.556%; WM, 0.324%; CSF, 0.573%; HC, 0.645%; OG, 1.74%; and CPL, 0.471%. The average percentage change was higher for the orbital gyrus than for the other ROIs. We consider that repeatability of the atlas-based method is similar between 0.4 and 1.5 tesla MR scanners. To our knowledge, this is the first report to show that the level of repeatability with a 0.4 tesla MR scanner is adequate for the estimation of brain volume change by the atlas-based method.

  7. The success of the 11-Tesla project and its potential beyond particle physics

    CERN Multimedia

    CERN Bulletin

    2013-01-01

    On 7 March, the 1-metre-long single-aperture dipole model magnet under testing at Fermilab reached a current of 12.54 kA corresponding to a bore field of 11.5 Tesla, thus surpassing the goal set for the 11 T dipole project.   Computer generated model of the FNAL 1 metre 11 T dipole model magnet and a pair of CERN coils. Image: courtesy of Don Mitchell, FNAL. The 11-Tesla dipole project originated from a proposal made by High Luminosity LHC project coordinator, Lucio Rossi, in September 2010. To cope with the increasing amount of debris hitting the magnets when increasing the number of collisions produced by the LHC, he suggested replacing a few 8-Tesla dipole magnets in the LHC tunnel with shorter, stronger 11-Tesla magnets in order to create enough space to install additional collimators. The only way to achieve this goal is to use advanced niobium-tin technology. Rossi’s proposal aligned well with the goals of Fermilab’s High-Field Magnet R&D programme, which aims t...

  8. Analysis of technical-economic requirements for the construction of a solar power plant on the roof of the business building of the Electrical Engineering Institute 'Nikola Tesla'

    OpenAIRE

    Grbić, Maja; Antić, Radoslav; Ponoćko, Jelena; Mikulović, Jovan; Đurišić, Željko

    2014-01-01

    This paper presents an analysis of the technical-economic requirements for the construction of a solar power plant on the roof of the business building of the Electrical Engineering Institute 'Nikola Tesla' in Belgrade. Calculation of solar irradiation is performed and the conceptual design of the disposition of solar panels on the roof of the building is shown as well as their connections to the inverters. Conditions for connecting the plant to the distribution network are checked and an eco...

  9. A 4-Tesla superconducting whole-body magnet for MR imaging and spectroscopy

    International Nuclear Information System (INIS)

    Vetter, J.; Ries, G.; Reichert, T.

    1988-01-01

    Since January 87 a 4 tesla MR magnet with a 1.25 m diameter warm bore is in operation at the Siemens Research Laboratories. The magnet weighing 10 tons is part of a whole-body MR device devoted to in-vivo research studies at magnetic fields significantly higher than 2 tesla; the highest field strength presently used in standard MR whole-body systems. The stored energy of the adiabatically stable six-coil system is 39 MJ at 4 tesla. The rated current is 376 A. Superconducting and resistive shim-coils together with iron shims reduce the bare magnet inhomogeneity of 100 ppm down to less than 5 ppm in a 50 cm diameter spherical volume. The magnet operates in persistent mode with the current leads retracted. The field drift is less than 3 x 10/sup -8//h. A small helium refrigerator is used to cool both the two radiation shields of the cryostat and the current leads and to reliquify the evaporating helium gas. Results of coil design, analysis of forces and stresses, quench protection, cryostat design and magnet operation are reported

  10. Nikola Tesla: een biografie

    NARCIS (Netherlands)

    ir.ing. Ruud Thelosen

    2015-01-01

    De Technische uitvinder Tesla heeft 700 patenten op zijn naam staan als hij overlijdt. Zijn uitvindingen hebben de wereld in de 20e eeuw volledig veranderd. Zijn wisselstroom generator hebben heel de VS van elektriciteit voorzien. Radioverkeer , remote control werd mogelijk dankzij Tesla. Volgens

  11. Study and development of an input coupler for the future TESLA collider

    International Nuclear Information System (INIS)

    Dupery, C.

    1996-01-01

    The TESLA (TeV Superconducting Linear Accelerator) is operating with a high frequency cavity resonator input coupler. Some technical restraints (such as thermal, mechanical, electrical, vacuum, multipactor discharge phenomena) constrain the development of this coupler. In order to solve these problems, studies have been performed at the French Atomic Energy Commission (CEA) and are presented in this paper

  12. Impact of high strength electromagnetic fields generated by Tesla transformer on plant cell ultrastructure

    Directory of Open Access Journals (Sweden)

    Anna Rusakova

    2017-09-01

    Full Text Available Non-thermal effects of direct electric fields and alternating electromagnetic fields (EMF have been successfully used in a number of studies and applications in agriculture and biotechnology. Among different kinds of high strength EMF generators, the Tesla transformer (TT is known as a widely applied, low cost, and troubleproof device, which generates EMF in the range of 2–8 MHz. Despite of a number of developed and perspective applications of high strength EMFs in agriculture and biotechnology, the EMFs generated by TT, as well as the 1–50 MHz range of high strength EMF still remain unexplored in the fields of plant physiology, ultrastructure studies and biochemistry. In this work, we have shown that TT-EMFs (4 MHz induced fast stem and petiole bending, disappearance of cell organelles, vacuolar membranes, and increase of a non-photochemical chlorophyll fluorescence quenching in petioles. It is intriguing that such fatal effects can be evoked in plants by EMFs which are well known as harmless for man at the applied strength and frequency.

  13. Superconductivity in Strong Magnetic Field (Greater Than Upper Critical Field)

    International Nuclear Information System (INIS)

    Tessema, G.X.; Gamble, B.K.; Skove, M.J.; Lacerda, A.H.; Mielke, C.H.

    1998-01-01

    The National High Magnetic Field Laboratory, funded by the National Science Foundation and other US federal Agencies, has in recent years built a wide range of magnetic fields, DC 25 to 35 Tesla, short pulse 50 - 60 Tesla, and quasi-continuous 60 Tesla. Future plans are to push the frontiers to 45 Tesla DC and 70 to 100 Tesla pulse. This user facility, is open for national and international users, and creates an excellent tool for materials research (metals, semiconductors, superconductors, biological systems ..., etc). Here we present results of a systematic study of the upper critical field of a novel superconducting material which is considered a promising candidate for the search for superconductivity beyond H c2 as proposed by several new theories. These theories predict that superconductors with low carrier density can reenter the superconducting phase beyond the conventional upper critical field H c2 . This negates the conventional thinking that superconductivity and magnetic fields are antagonistic

  14. Tesla - A Flash of a Genius

    Science.gov (United States)

    Teodorani, M.

    2005-10-01

    This book, which is entirely dedicated to the inventions of scientist Nikola Tesla, is divided into three parts: a) all the most important innovative technological creations from the alternate current to the death ray, Tesla research in fundamental physics with a particular attention to the concept of "ether", ball lightning physics; b) the life and the bright mind of Nikola Tesla and the reasons why some of his most recent findings were not accepted by the establishment; c) a critical discussion of the most important work by Tesla followers.

  15. Prospects for 6 to 10 tesla magnets for a TEVATRON upgrade

    International Nuclear Information System (INIS)

    Mantsch, Paul M.

    1988-01-01

    The first SSC physics is at least 10 years away. An upgrade of the Fermilab Tevatron will ensure the continuity of a vigorous high-energy physics program until the SSC turns on. Three basic proposals are under consideration: /bar p/p at 3 /times/ 10 31 --Increase luminosity by improvements to the p source. pp at 1 TeV and 2 /times/ 10 32 --Move the main ring to a new tunnel, build a second Tevatron ring, and /bar p/p > 1.5 TeV and 7 /times/ 10 30 --Replace the tevatron with a higher energy ring. The last two options requires about a hundred 6.6-tesla dipoles in addition to a ring of Tevatron strength (4.4 T) magnets. These higher-field magnets are necessary in both rings to lengthen the straight sections in order to realize the collision optics. The third option requires a ring of magnets of 6.6 T or slightly higher to replace the present Tevatron plus a number of special 8--9 tesla magnets. The viability of the high-energy option then depends on the practicality of sizable numbers of reliable 8--9 tesla dipoles as well as 800 6.6-tesla dipoles. The following develops a specification for an 8.8 T dipole, examines the design considerations and reviews the current state of high-field magnet development. 22 figs., 3 tabs

  16. CERN: Ten-Tesla twin

    International Nuclear Information System (INIS)

    Anon.

    1991-01-01

    An important step in the development of the high field superconducting magnets for CERN's proposed LHC proton collider came on 21 October when a 1 metre-long model of the proposed twin-dipole magnet produced a field of 10 Tesla in its two o beam apertures at the design temperature of 1.8K. The LHC designers have to plan for proton beams approaching 8 TeV to attain the right conditions for the quarks and gluons hidden deep inside protons to produce new physics. To contain these very high energy protons in the tight track of the 27-kilometre LEP tunnel would need the strongest magnetic bending power ever used in a full storage ring

  17. Analysis of technical-economic requirements for the construction of a solar power plant on the roof of the business building of the Electrical Engineering Institute 'Nikola Tesla'

    Directory of Open Access Journals (Sweden)

    Grbić Maja

    2014-01-01

    Full Text Available This paper presents an analysis of the technical-economic requirements for the construction of a solar power plant on the roof of the business building of the Electrical Engineering Institute 'Nikola Tesla' in Belgrade. Calculation of solar irradiation is performed and the conceptual design of the disposition of solar panels on the roof of the building is shown as well as their connections to the inverters. Conditions for connecting the plant to the distribution network are checked and an economic analysis of the project is performed.

  18. Status and outlook for high power processing of 1.3 GHz TESLA multicell cavities

    International Nuclear Information System (INIS)

    Kirchgessner, J.; Barnes, P.; Graber, J.; Metzger, D.; Mofat, D.; Muller, H.; Padamsee, H.; Sears, J.; Tigner, M.; Matheisen, A.

    1993-01-01

    In order to increase the usable accelerating gradient in Superconducting TESLA cavities, the field emission threshold barrier must be raised. As has been previously demonstrated on S-band cavities, a way to accomplish this is with the use of high peak power RF processing. A transmitter with a peak power of 2 Mwatt and 300 μsec pulse length has been assembled and has been used to process TESLA cavities. Several five cell TESLA cavities at 1.3 GHz have been manufactured for this purpose. This transmitter and the cavities will be described and the results of the tests will be presented

  19. Imaging of patients with hippocampal sclerosis at 7 Tesla: initial results.

    Science.gov (United States)

    Breyer, Tobias; Wanke, Isabel; Maderwald, Stefan; Woermann, Friedrich G; Kraff, Oliver; Theysohn, Jens M; Ebner, Alois; Forsting, Michael; Ladd, Mark E; Schlamann, Marc

    2010-04-01

    Focal epilepsies potentially can be cured by neurosurgery; other treatment options usually remain symptomatic. High-resolution magnetic resonance (MR) imaging is the central imaging strategy in the evaluation of focal epilepsy. The most common substrate of temporal epilepsies is hippocampal sclerosis (HS), which cannot always be sufficiently characterized with current MR field strengths. Therefore, the purpose of our study was to demonstrate the feasibility of high-resolution MR imaging at 7 Tesla in patients with focal epilepsy resulting from a HS and to improve image resolution at 7 Tesla in patients with HS. Six patients with known HS were investigated with T1-, T2-, T2(*)-, and fluid-attenuated inversion recovery-weighted sequences at 7 Tesla with an eight-channel transmit-receive head coil. Total imaging time did not exceed 90 minutes per patient. High-resolution imaging at 7 Tesla is feasible and reveals high resolution of intrahippocampal structures in vivo. HS was confirmed in all patients. The maximum non-interpolated in-plane resolution reached 0.2 x 0.2 mm(2) in T2(*)-weighted images. The increased susceptibility effects at 7 Tesla revealed identification of intrahippocampal structures in more detail than at 1.5 Tesla, but otherwise led to stronger artifacts. Imaging revealed regional differences in hippocampal atrophy between patients. The scan volume was limited because of specific absorption rate restrictions, scanning time was reasonable. High-resolution imaging at 7 Tesla is promising in presurgical epilepsy imaging. "New" contrasts may further improve detection of even very small intrahippocampal structural changes. Therefore, further investigations will be necessary to demonstrate the potential benefit for presurgical selection of patients with various lesion patterns in mesial temporal epilepsies resulting from a unilateral HS. Copyright 2010 AUR. Published by Elsevier Inc. All rights reserved.

  20. Tesla coil theoretical model and experimental verification

    OpenAIRE

    Voitkans, Janis; Voitkans, Arnis

    2014-01-01

    Abstract – In this paper a theoretical model of a Tesla coil operation is proposed. Tesla coil is described as a long line with distributed parameters in a single-wired format, where the line voltage is measured against electrically neutral space. It is shown that equivalent two-wired scheme can be found for a single-wired scheme and already known long line theory can be applied to a Tesla coil. Formulas for calculation of voltage in a Tesla coil by coordinate and calculation of resonance fre...

  1. Prospects for 6- to 10-Tesla magnets for a Tevatron upgrade

    International Nuclear Information System (INIS)

    Mantsch, P.M.

    1989-01-01

    This paper reports on prospects for 6- to 10-tesla magnets for a Teratron upgrade. The first SSC physics is at least 10 years away. An upgrade of the Fermilab Tevatron will ensure the continuity of a vigorous high-energy physics program until the SSC turns on. Three basic proposals are under consideration: (1) bar pp at 3 x 10 31 --Increase luminosity by improvements to the bar p source. (2) p bar p at 1 TeV and 2 x 10 32 --Move the main ring to a new tunnel, build a second Tevatron ring. (3) bar pp > 1.5 TeV and 7 x 10 30 --Replace the Tevatron with a higher energy ring. The last two options require new higher-field magnets. The second option requires about a hundred 6.6-tesla dipoles in addition to a ring of Tevatron-strength (4.4-T) magnets. These higher-field magnets are necessary in both rings to lengthen the straight sections in order to realize the collision optics. The third option requires a ring of magnets of 6.6 T or slightly higher to replace the present Tevatron plus a number of special 8- to 9-tesla magnets

  2. Dynamic contrast-enhanced breast MRI at 7 Tesla utilizing a single-loop coil: a feasibility trial.

    Science.gov (United States)

    Umutlu, Lale; Maderwald, Stefan; Kraff, Oliver; Theysohn, Jens M; Kuemmel, Sherko; Hauth, Elke A; Forsting, Michael; Antoch, Gerald; Ladd, Mark E; Quick, Harald H; Lauenstein, Thomas C

    2010-08-01

    The aim of this study was to assess the feasibility of dynamic contrast-enhanced ultra-high-field breast imaging at 7 Tesla. A total of 15 subjects, including 5 patients with histologically proven breast cancer, were examined on a 7 Tesla whole-body magnetic resonance imaging system using a unilateral linearly polarized single-loop coil. Subjects were placed in prone position on a biopsy support system, with the coil placed directly below the region of interest. The examination protocol included the following sequences: 1) T2-weighted turbo spin echo sequence; 2) six dynamic T1-weighted spoiled gradient-echo sequences; and 3) subtraction imaging. Contrast-enhanced T1-weighted imaging at 7 Tesla could be obtained at high spatial resolution with short acquisition times, providing good image accuracy and a conclusively good delineation of small anatomical and pathological structures. T2-weighted imaging could be obtained with high spatial resolution at adequate acquisition times. Because of coil limitations, four high-field magnetic resonance examinations showed decreased diagnostic value. This first scientific approach of dynamic contrast-enhanced breast magnetic resonance imaging at 7 Tesla demonstrates the complexity of ultra-high-field breast magnetic resonance imaging and countenances the implementation of further advanced bilateral coil concepts to circumvent current limitations from the coil and ultra-high-field magnetic strength. 2010 AUR. Published by Elsevier Inc. All rights reserved.

  3. TESLA Test Facility. Status

    International Nuclear Information System (INIS)

    Aune, B.

    1996-01-01

    The TESLA Test Facility (TTF), under construction at DESY by an international collaboration, is an R and D test bed for the superconducting option for future linear e+/e-colliders. It consists of an infrastructure to process and test the cavities and of a 500 MeV linac. The infrastructure has been installed and is fully operational. It includes a complex of clean rooms, an ultra-clean water plant, a chemical etching installation and an ultra-high vacuum furnace. The linac will consist of four cryo-modules, each containing eight 1 meter long nine-cell cavities operated at 1.3 GHz. The base accelerating field is 15 MV/m. A first injector will deliver a low charge per bunch beam, with the full average current (8 mA in pulses of 800 μs). A more powerful injector based on RF gun technology will ultimately deliver a beam with high charge and low emittance to allow measurements necessary to qualify the TESLA option and to demonstrate the possibility of operating a free electron laser based on the Self-Amplified-Spontaneous-Emission principle. Overview and status of the facility will be given. Plans for the future use of the linac are presented. (R.P.)

  4. Generating Long Scale-Length Plasma Jets Embedded in a Uniform, Multi-Tesla Magnetic-Field

    Science.gov (United States)

    Manuel, Mario; Kuranz, Carolyn; Rasmus, Alex; Klein, Sallee; Fein, Jeff; Belancourt, Patrick; Drake, R. P.; Pollock, Brad; Hazi, Andrew; Park, Jaebum; Williams, Jackson; Chen, Hui

    2013-10-01

    Collimated plasma jets emerge in many classes of astrophysical objects and are of great interest to explore in the laboratory. In many cases, these astrophysical jets exist within a background magnetic field where the magnetic pressure approaches the plasma pressure. Recent experiments performed at the Jupiter Laser Facility utilized a custom-designed solenoid to generate the multi-tesla fields necessary to achieve proper magnetization of the plasma. Time-gated interferometry, Schlieren imaging, and proton radiography were used to characterize jet evolution and collimation under varying degrees of magnetization. Experimental results will be presented and discussed. This work is funded by the NNSA-DS and SC-OFES Joint Program in High-Energy-Density Laboratory Plasmas, grant number DE-NA0001840, by the National Laser User Facility Program, grant number DE-NA0000850, by the Predictive Sciences Academic Alliances Program in NNSA-ASC, grant number DEFC52-08NA28616, and by NASA through Einstein Postdoctoral Fellowship grant number PF3-140111 awarded by the Chandra X-ray Center, which is operated by the Smithsonian Astrophysical Observatory for NASA under contract NAS8-03060.

  5. Impetus for TESLA ! DESY welcomes decision of the Federal Research Ministry on large-scale facilities

    CERN Multimedia

    2003-01-01

    Based on the decision published today by the Federal Minister of Education and Research, Edelgard Bulmahn, the preparations for TESLA will now enter a new phase. For the X-ray laser project, the first step will be to work out the financial, technical and organizational framework with the interested European partners (1 page).

  6. Superconducting TESLA cavities

    Directory of Open Access Journals (Sweden)

    B. Aune

    2000-09-01

    Full Text Available The conceptional design of the proposed linear electron-positron collider TESLA is based on 9-cell 1.3 GHz superconducting niobium cavities with an accelerating gradient of E_{acc}≥25 MV/m at a quality factor Q_{0}≥5×10^{9}. The design goal for the cavities of the TESLA Test Facility (TTF linac was set to the more moderate value of E_{acc}≥15 MV/m. In a first series of 27 industrially produced TTF cavities the average gradient at Q_{0}=5×10^{9} was measured to be 20.1±6.2 MV/m, excluding a few cavities suffering from serious fabrication or material defects. In the second production of 24 TTF cavities, additional quality control measures were introduced, in particular, an eddy-current scan to eliminate niobium sheets with foreign material inclusions and stringent prescriptions for carrying out the electron-beam welds. The average gradient of these cavities at Q_{0}=5×10^{9} amounts to 25.0±3.2 MV/m with the exception of one cavity suffering from a weld defect. Hence only a moderate improvement in production and preparation techniques will be needed to meet the ambitious TESLA goal with an adequate safety margin. In this paper we present a detailed description of the design, fabrication, and preparation of the TESLA Test Facility cavities and their associated components and report on cavity performance in test cryostats and with electron beam in the TTF linac. The ongoing research and development towards higher gradients is briefly addressed.

  7. Diffusion-weighted MR imaging of the normal pancreas: reproducibility and variations of apparent diffusion coefficient measurement at 1.5- and 3.0-Tesla.

    Science.gov (United States)

    Barral, M; Soyer, P; Ben Hassen, W; Gayat, E; Aout, M; Chiaradia, M; Rahmouni, A; Luciani, A

    2013-04-01

    To evaluate reproducibility and variations in apparent diffusion coefficient (ADC) measurement in normal pancreatic parenchyma at 1.5- and 3.0-Tesla and determine if differences may exist between the four pancreatic segments. Diffusion-weighted MR imaging of the pancreas was performed at 1.5-Tesla in 20 patients and at 3.0-Tesla in other 20 patients strictly matched for gender and age using the same b values (0, 400 and 800s/mm(2)). Two independent observers placed regions of interest within the four pancreatic segments to measure ADC at both fields. Intra- and inter-observer agreement in ADC measurement was assessed using Bland-Altman analysis and comparison between ADC values obtained at both fields using non-parametrical tests. There were no significant differences in ADC between repeated measurements and between ADC obtained at 1.5-Tesla and those at 3.0-Tesla. The 95% limits of intra-observer agreement between ADC were 2.3%-22.7% at 1.5-Tesla and 1%-24.2% at 3.0-Tesla and those for inter-observer agreement between 1.9%-14% at 1.5-Tesla and 8%-25% at 3.0-Tesla. ADC values were similar in all pancreatic segments at 3.0-T whereas the tail had lower ADC at 1.5-Tesla. ADC measurement conveys high degrees of intra- and inter-observer reproducibility. ADC have homogeneous distribution among the four pancreatic segments at 3.0-Tesla. Copyright © 2012 Éditions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.

  8. Jakob Narkiewicz-Jodko-Tesla ``Predecessor''

    Science.gov (United States)

    Samuilov, Vladimir; Kiselev, Vladimir

    2014-03-01

    Prof. Jakob Narkiewicz-Jodko (1947-1905) is a bright figure in the history of science of the XIXth century. His major discoveries are: Electrography - the method of the visualization of electric discharge from the bodies due to the application of high strength and high frequency electric fields, and one of the first observations of the propagation of the electromagnetic waives and information transfer over the distances. We review Prof. Jakob Narkiewicz-Jodko's research results and explain our point why we consider him as the predecessor of Nikola Tesla.

  9. Small horizontal emittance in the TESLA damping ring

    International Nuclear Information System (INIS)

    Decking, W.

    2001-01-01

    The present TESLA damping ring is designed for a normalized horizontal emittance of 8x10 -6 m. γ-γ collisions at the TESLA linear collider will benefit from a further decrease of the horizontal emittance. This paper reviews the processes which limit the horizontal emittance in the damping ring. Preliminary estimates on the smallest horizontal emittance for the present TESLA damping ring design as well as an ultimate limit of the emittance reachable with the TESLA damping ring concept will be given

  10. NIKOLA TESLA AND THE X-RAY

    OpenAIRE

    Rade R. Babic

    2005-01-01

    After professor Wilhelm Konrad Röntgen published his study of an x-ray discovery (Academy Bulletin, Berlin, 08. 11. 1895.), Nikola Tesla published his first study of an x-ray on the 11th of March in 1896. (X-ray, Electrical Review). Until the 11th of August in 1897 he had published ten studies on this subject. All Tesla,s x-ray studies were experimental, which is specific to his work. Studying the nature of the x-ray, he established a new medical branch-radiology. He wrote:” There’s no doubt...

  11. Tesla Roadsterin vauriokorjaus

    OpenAIRE

    Hiltunen, Santeri

    2016-01-01

    Insinöörityössä perehdyttiin Tesla-sähköauton rakenteeseen sekä korjaamiseen, sähkötyö-turvallisuuteen sekä sähkötekniikkaan. Työn tavoitteena on selvittää, mitä laki vaatii sähköauton korjaamiseen, ja kuinka saada varaosia ja ohjeita ajoneuvoon, jolla ei ole Suomessa maahantuojaa. Lisäksi tavoitteena oli selvittää, minkälainen auto on kyseessä sekä mitä materiaaleja autoon on käytetty. Työssä korjattiin takaosasta mekaanisilta osiltaan vaurioitunut Tesla Roadster -merkkinen sähköaut...

  12. About the origin of matter - the TESLA project

    International Nuclear Information System (INIS)

    Heuer, R.D.

    2004-01-01

    An introduction to the TESLA project is given. After a general introduction to the standard model of elementary particles together with some possible extension the scientific potential of TESLA is described with special regards to the production of Higgs bosons and supersymmetric particles. Finally the technology of TESLA is considered. (HSI)

  13. Ultra high field magnetic resonance imaging; L'imagerie par resonance magnetique a ultra-haut champ. L'aimant, piece maitresse de l'imageur. Memo C: les principales techniques d'imagerie medicale

    Energy Technology Data Exchange (ETDEWEB)

    Lethimonnier, F. [CEA Saclay, Institut d' Imagerie Biomedicale - NeuroSpin, Dir. des Sciences du Vivant, 91 - Gif-sur-Yvette (France); Vedrine, P. [CEA Saclay, Direction des Sciences de la Matiere, 91 - Gif-sur-Yvette (France)

    2008-07-01

    Understanding human brain function, brain development and brain dysfunction is one of the great challenges of the twenty first century. Biomedical imaging has now run up against a number of technical constraints that are exposing limits to its potential. In order to overcome the current limits to high-field magnetic resonance cerebral imaging (MRI) and unleash its fullest potential, the Cea has built NeuroSpin, an ultra-high-field neuroimaging facility at its Saclay centre (in the Essonne). NeuroSpin already boasts three fully operational MRI systems. The first is a 3-tesla high-field system and the second is a very-high-field 7-tesla system, both of which are dedicated to clinical studies and investigations in humans, while the third is an ultra-high-field 17.65-tesla system designed for studies on small animals. In 2011, NeuroSpin will be commissioning an 11.7-tesla ultra-high-field system of unprecedented power that is designed for research on human subjects. The level of the magnetic field and the scale required will make this joint French-German project to build the magnet a breakthrough in the international arena. (authors)

  14. Rapid parametric mapping of the longitudinal relaxation time T1 using two-dimensional variable flip angle magnetic resonance imaging at 1.5 Tesla, 3 Tesla, and 7 Tesla.

    Science.gov (United States)

    Dieringer, Matthias A; Deimling, Michael; Santoro, Davide; Wuerfel, Jens; Madai, Vince I; Sobesky, Jan; von Knobelsdorff-Brenkenhoff, Florian; Schulz-Menger, Jeanette; Niendorf, Thoralf

    2014-01-01

    Visual but subjective reading of longitudinal relaxation time (T1) weighted magnetic resonance images is commonly used for the detection of brain pathologies. For this non-quantitative measure, diagnostic quality depends on hardware configuration, imaging parameters, radio frequency transmission field (B1+) uniformity, as well as observer experience. Parametric quantification of the tissue T1 relaxation parameter offsets the propensity for these effects, but is typically time consuming. For this reason, this study examines the feasibility of rapid 2D T1 quantification using a variable flip angles (VFA) approach at magnetic field strengths of 1.5 Tesla, 3 Tesla, and 7 Tesla. These efforts include validation in phantom experiments and application for brain T1 mapping. T1 quantification included simulations of the Bloch equations to correct for slice profile imperfections, and a correction for B1+. Fast gradient echo acquisitions were conducted using three adjusted flip angles for the proposed T1 quantification approach that was benchmarked against slice profile uncorrected 2D VFA and an inversion-recovery spin-echo based reference method. Brain T1 mapping was performed in six healthy subjects, one multiple sclerosis patient, and one stroke patient. Phantom experiments showed a mean T1 estimation error of (-63±1.5)% for slice profile uncorrected 2D VFA and (0.2±1.4)% for the proposed approach compared to the reference method. Scan time for single slice T1 mapping including B1+ mapping could be reduced to 5 seconds using an in-plane resolution of (2×2) mm2, which equals a scan time reduction of more than 99% compared to the reference method. Our results demonstrate that rapid 2D T1 quantification using a variable flip angle approach is feasible at 1.5T/3T/7T. It represents a valuable alternative for rapid T1 mapping due to the gain in speed versus conventional approaches. This progress may serve to enhance the capabilities of parametric MR based lesion detection and

  15. Predesign Study of a 4-5 tesla Superconducting Wiggler Magnet for the ESRF

    NARCIS (Netherlands)

    ten Kate, Herman H.J.; ter Avest, D.; ter Avest, D.; Ravex, A.; Lagnier, M.; Elleaume, P.

    1994-01-01

    The ESRF is currently setting up a beam line for very hard photons well above 250 keV. This requires the installation of a high field three polewavelength shifter. The nominal and target fields of the wiggler magnet are 4 and 5 tesla respectively while the nominal field integral over the central

  16. Tesla Coil Theoretical Model and its Experimental Verification

    Directory of Open Access Journals (Sweden)

    Voitkans Janis

    2014-12-01

    Full Text Available In this paper a theoretical model of Tesla coil operation is proposed. Tesla coil is described as a long line with distributed parameters in a single-wire form, where the line voltage is measured across electrically neutral space. By applying the principle of equivalence of single-wire and two-wire schemes an equivalent two-wire scheme can be found for a single-wire scheme and the already known long line theory can be applied to the Tesla coil. A new method of multiple reflections is developed to characterize a signal in a long line. Formulas for calculation of voltage in Tesla coil by coordinate and calculation of resonance frequencies are proposed. The theoretical calculations are verified experimentally. Resonance frequencies of Tesla coil are measured and voltage standing wave characteristics are obtained for different output capacities in the single-wire mode. Wave resistance and phase coefficient of Tesla coil is obtained. Experimental measurements show good compliance with the proposed theory. The formulas obtained in this paper are also usable for a regular two-wire long line with distributed parameters.

  17. Design of a 6 Tesla wiggler for the National Synchrotron Light Source

    International Nuclear Information System (INIS)

    Hsieh, H.; Krinsky, S.; Luccio, A.; van Steenbergen, A.

    1981-01-01

    A 6-pole, 6 Tesla wiggler with Nb-Ti superconducting windings has been designed, to be installed in a straight section of the 2.5 GeV x-ray storage ring of the NSLS. The technical problems of this magnet are discussed, in particular the optimization of the two-layer magnetic windings and the mechanical structure designed to counteract the strong magnetic forces. The effects of the insertion of the wiggler in the storage ring lattice are also studied

  18. The forced flow high field test facility SULTAN

    International Nuclear Information System (INIS)

    Horvath, I.; Vecsey, G.; Weymuth, P.

    1984-01-01

    The construction of the 8 Tesla, 1 m bore Test Facility SULTAN - I, a common action of ENEA (I-Frascati), ECN (NL-Petten) and SIN (CH-Villigen), is completed. Results on assembly, cooldown and the first operation of the whole system are presented. The SULTAN facility provides a wide range of capability of parameter variations (field, current, cooling) for the investigation of steady state performance and stability of technical superconductors unders nominal and limiting conditions

  19. 3D calculations of the Superconducting Super Collider (SSC) 3 Tesla magnet

    International Nuclear Information System (INIS)

    Lari, R.J.

    1984-01-01

    A 20 TeV Superconducting Super Collider (SSC) proton accelerator is being proposed by the High Energy Physics Community. One proposal would consist of a ring of magnets 164 km in circumference with a field strength of 3 Tesla and would cost 2.7 billion dollars. The magnet consists of stacked steel laminations with superconducting coils. The desired field uniformity is obtained for all fields from 0.2 to 3 Tesla by using three (or more) different pole shapes. These three different laminations are stacked in the order 1-2-3-1-2-3-... creating a truly three dimensional geometry. A three laminated stack 1-2-3 with periodic boundary conditions at 1 and 3 was assigned about 5000 finite elements per lamination and solved using the computer program TOSCA. To check the TOSCA results, the field of each of the three different shaped laminations was calculated separately using periodic boundary conditions and compared to the two dimensional field calculations using TRIM. This was done for a constant permeability of 2000 and using the B-H table for fully annealed 1010 steel. The difference of the field calculations in the region of interest was always less than +-.2%

  20. TeSLA e-assessment workshop pilot 2

    OpenAIRE

    Janssen, José

    2017-01-01

    Presentatie ten behoeve van de e-assessment workshop voor docenten van de Open Universiteit Nederland betrokken in de tweede TeSLA pilot. Topics: toetsfraude, toetsdesign, technologie voor authenticatie en verificatie van auteurschap, TeSLA instrument.

  1. The influence of potential exposure to radiation protection system of accelerator installation TESLA

    International Nuclear Information System (INIS)

    Orlic, M.; Cuknic, O.

    2000-01-01

    Potential exposure of individuals at big nuclear machines like Accelerator Installation Tesla (AIT) generates direct requirements to reliability of radiation protection system. Starting from technical characteristics of AlT and international recommendation concerning potential exposure and the probability of death has been calculated. The reference risk has been specified. Comparing then we calculated the probability of the failure of the protective system. The reliability of the system has to be better (author)

  2. MR cholangiopancreatography. Comparison of images obtained with 1.0 and 1.5 tesla units

    International Nuclear Information System (INIS)

    Yasui, Masayasu; Ito, Katsuyoshi; Koike, Shinji; Matsunaga, Naofumi

    2002-01-01

    The purpose of this study was to compare the image quality and visualization obtained in MR cholangiopancreatography (MRCP) using different high-field strength (1.0 vs. 1.5 Tesla) MR units and to assess the effect of field strength on MRCP. This study population included 10 healthy volunteers and 37 patients suspected of having pancreatobiliary diseases. MRCP images were obtained using two MR units with different high-field strengths (1.0 and 1.5 Tesla), with half-Fourier acquisition single-shot turbo spin-echo (HASTE) and rapid acquisition by relaxation enhancement (RARE) sequences. The image quality and visualization of each portion of the pancreatobiliary system were graded and recorded using a four-point scale. Additionally, the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were measured. The SNR and CNR in HASTE sequences acquired with the 1.5 Tesla (T) unit were significantly higher than those acquired with the 1.0 T unit (p=0.001). In qualitative analysis, there were no statistically significant differences in image quality or visualization of the ducts in either HASTE or RARE sequences between 1.0 T and 1.5 T. Our study showed that visual image quality provided by MRCP was equivalent at 1.0 and 1.5 T. (author)

  3. T2 relaxation time in patellar cartilage - global and regional reproducibility at 1.5 Tesla and 3 Tesla

    International Nuclear Information System (INIS)

    Glaser, C.; Horng, A.; Mendlik, T.; Weckbach, S.; Hoffmann, R.T.; Wagner, S.; Raya, J.G.; Reiser, M.; Horger, W.

    2007-01-01

    Purpose: Evaluation of the global and regional reproducibility of T2 relaxation time in patellar cartilage at 1.5 T and 3 T. Materials and Methods: 6 left patellae of 6 healthy volunteers (aged 25-30, 3 female, 3 male) were examined using a fat-saturated multiecho sequence and a T1-w 3D-FLASH sequence with water excitation at 1.5 Tesla and 3 Tesla. Three consecutive data sets were acquired within one MRI session with the examined knee being repositioned in the coil and scanner between each data set. The segmented cartilage (FLASH sequence) was overlaid on the multiecho data and T2 values were calculated for the total cartilage, 3 horizontal layers consisting of a superficial, intermedial and deep layer, 3 facets consisting of a medial, median (ridge) and lateral facet (global T2 values) and 27 ROIs/MRI slices (regional T2 value). The reproducibility (precision error) was calculated as the root mean square average of the individual standard deviations [ms] and coefficients of variation (COV) [%]. Results: The mean global reproducibility error for T2 was 3.53% (±0.38%) at 1.5 Tesla and 3.25% (±0.61%) at 3 Tesla. The mean regional reproducibility error for T2 was 8.62% (±2.61%) at 1.5 Tesla and 9.66% (±3.37%) at 3 Tesla. There was no significant difference with respect to absolute reproducibility errors between 1.5 Tesla and 3 Tesla at a constant spatial resolution. However, different reproducibility errors were found between the cartilage layers. One third of the data variability could be attributed to the influence of the different cartilage layers, and another 10% to the influence of the separate MRI slices. Conclusion: Our data provides an estimation of the global and regional reproducibility errors of T2 in healthy cartilage. In the analysis of small subregions, an increase in the regional reproducibility error must be accepted. The data may serve as a basis for sample size calculations of study populations and may contribute to the decision regarding the

  4. TeSLA workshop betrouwbaar toetsen op afstand

    NARCIS (Netherlands)

    Brouns, Francis; Janssen, José

    2017-01-01

    Presentatie ten behoeve van workshop betrouwbaar toetsen op afstand voor docenten van de Open Universiteit Nederland betrokken in de derde TeSLA pilot. Topics: toetsfraude, toetsdesign, technologie voor authenticatie en verificatie van auteurschap, TeSLA instrumenten.

  5. Diffusion tensor imaging of the spinal cord at 1.5 and 3.0 Tesla

    Energy Technology Data Exchange (ETDEWEB)

    Rossi, C. [Radiologische Universitaetsklinik, Tuebingen (Germany). Sektion fuer Experimentelle Radiologie; CNR-INFM CRS-Soft, La Sapienza-Univ. Roma (Italy); Enrico Fern Center, Roma (Italy); Boss, A.; Martirosian, P.; Steidle, G.; Schick, F. [Radiologische Universitaetsklinik, Tuebingen (Germany). Sektion fuer Experimentelle Radiologie; Lindig, T.M. [Enrico Fern Center, Roma (Italy); Radiologische Universitaetsklinik, Tuebingen (Germany). Sektion fuer Experimentelle Kernspinresonanz des ZNS; Universitaetsklinikum Tuebingen (Germany). Zentrum fuer Neurologie und Hertie-Inst. fuer klinische Hirnforschung; Maetzler, W. [Universitaetsklinikum Tuebingen (Germany). Zentrum fuer Neurologie und Hertie-Inst. fuer klinische Hirnforschung; Claussen, C.D. [Radiologische Universitaetsklinik, Tuebingen (Germany). Abt. fuer Radiologische Diagnostik; Klose, U. [Radiologische Universitaetsklinik, Tuebingen (Germany). Sektion fuer Experimentelle Kernspinresonanz des ZNS

    2007-03-15

    Purpose: The feasibility of highly resolved diffusion tensor imaging (DTI) of the human cervical spinal cord was tested on a clinical MR unit operating at 3.0 Tesla. DTI parametrical maps and signal-to-noise ratios (SNRs) were compared to results recorded at 1.5 Tesla. Materials and Methods: Eight healthy volunteers and one patient participated in the study. A transverse oriented single-shot ECG-triggered echo-planar imaging (EPI) sequence with double spin-echo diffusion preparation was applied for highly resolved DTI of the spinal cord. The signal yield, fractional anisotropy (FA), and mean diffusivity (MD) were compared for both field strengths. The clinical applicability of the protocol was also tested in one patient with amyotrophic lateral sclerosis (ALS) at 3.0 T. Results: A mean increase in SNR of 95.7 {+-} 4.6% was found at 3.0 Tesla compared to 1.5 Tesla. Improved quality of the DTI parametrical maps was observed at higher field strength (p < 0.02). Comparable FA and MD (reported in units of 10 - 3 mm2/s) values were computed in the dorsal white matter at both field strengths (1.5 T: FA = 0.75 {+-} 0.08, MD = 0.84 {+-} 0.12, 3.0 T: FA = 0.74 {+-} 0.04, MD = 0.93 {+-} 0.14). The DTI images exhibited diagnostic image quality in the patient. At the site of the diseased corticospinal tract, a decrease of 46.0 {+-} 3.8% in FA (0.40 {+-} 0.03) and an increase of 50.3 {+-} 5.6% in MD (1.40 {+-} 0.05) were found in the ALS patient. (orig.)

  6. Diffusion tensor imaging of the spinal cord at 1.5 and 3.0 Tesla

    International Nuclear Information System (INIS)

    Rossi, C.; Boss, A.; Martirosian, P.; Steidle, G.; Schick, F.; Lindig, T.M.; Radiologische Universitaetsklinik, Tuebingen; Universitaetsklinikum Tuebingen; Maetzler, W.; Claussen, C.D.; Klose, U.

    2007-01-01

    Purpose: The feasibility of highly resolved diffusion tensor imaging (DTI) of the human cervical spinal cord was tested on a clinical MR unit operating at 3.0 Tesla. DTI parametrical maps and signal-to-noise ratios (SNRs) were compared to results recorded at 1.5 Tesla. Materials and Methods: Eight healthy volunteers and one patient participated in the study. A transverse oriented single-shot ECG-triggered echo-planar imaging (EPI) sequence with double spin-echo diffusion preparation was applied for highly resolved DTI of the spinal cord. The signal yield, fractional anisotropy (FA), and mean diffusivity (MD) were compared for both field strengths. The clinical applicability of the protocol was also tested in one patient with amyotrophic lateral sclerosis (ALS) at 3.0 T. Results: A mean increase in SNR of 95.7 ± 4.6% was found at 3.0 Tesla compared to 1.5 Tesla. Improved quality of the DTI parametrical maps was observed at higher field strength (p < 0.02). Comparable FA and MD (reported in units of 10 - 3 mm2/s) values were computed in the dorsal white matter at both field strengths (1.5 T: FA = 0.75 ± 0.08, MD = 0.84 ± 0.12, 3.0 T: FA 0.74 ± 0.04, MD = 0.93 ± 0.14). The DTI images exhibited diagnostic image quality in the patient. At the site of the diseased corticospinal tract, a decrease of 46.0 ± 3.8% in FA (0.40 ± 0.03) and an increase of 50.3 ± 5.6% in MD (1.40 ± 0.05) were found in the ALS patient. (orig.)

  7. SU-F-J-166: Volumetric Spatial Distortions Comparison for 1.5 Tesla Versus 3 Tesla MRI for Gamma Knife Radiosurgery Scans Using Frame Marker Fusion and Co-Registration Modes

    International Nuclear Information System (INIS)

    Neyman, G

    2016-01-01

    Purpose: To compare typical volumetric spatial distortions for 1.5 Tesla versus 3 Tesla MRI Gamma Knife radiosurgery scans in the frame marker fusion and co-registration frame-less modes. Methods: Quasar phantom by Modus Medical Devices Inc. with GRID image distortion software was used for measurements of volumetric distortions. 3D volumetric T1 weighted scans of the phantom were produced on 1.5 T Avanto and 3 T Skyra MRI Siemens scanners. The analysis was done two ways: for scans with localizer markers from the Leksell frame and relatively to the phantom only (simulated co-registration technique). The phantom grid contained a total of 2002 vertices or control points that were used in the assessment of volumetric geometric distortion for all scans. Results: Volumetric mean absolute spatial deviations relatively to the frame localizer markers for 1.5 and 3 Tesla machine were: 1.39 ± 0.15 and 1.63 ± 0.28 mm with max errors of 1.86 and 2.65 mm correspondingly. Mean 2D errors from the Gamma Plan were 0.3 and 1.0 mm. For simulated co-registration technique the volumetric mean absolute spatial deviations relatively to the phantom for 1.5 and 3 Tesla machine were: 0.36 ± 0.08 and 0.62 ± 0.13 mm with max errors of 0.57 and 1.22 mm correspondingly. Conclusion: Volumetric spatial distortions are lower for 1.5 Tesla versus 3 Tesla MRI machines localized with markers on frames and significantly lower for co-registration techniques with no frame localization. The results show the advantage of using co-registration technique for minimizing MRI volumetric spatial distortions which can be especially important for steep dose gradient fields typically used in Gamma Knife radiosurgery. Consultant for Elekta AB

  8. SU-F-J-166: Volumetric Spatial Distortions Comparison for 1.5 Tesla Versus 3 Tesla MRI for Gamma Knife Radiosurgery Scans Using Frame Marker Fusion and Co-Registration Modes

    Energy Technology Data Exchange (ETDEWEB)

    Neyman, G [The Cleveland Clinic Foundation, Cleveland, OH (United States)

    2016-06-15

    Purpose: To compare typical volumetric spatial distortions for 1.5 Tesla versus 3 Tesla MRI Gamma Knife radiosurgery scans in the frame marker fusion and co-registration frame-less modes. Methods: Quasar phantom by Modus Medical Devices Inc. with GRID image distortion software was used for measurements of volumetric distortions. 3D volumetric T1 weighted scans of the phantom were produced on 1.5 T Avanto and 3 T Skyra MRI Siemens scanners. The analysis was done two ways: for scans with localizer markers from the Leksell frame and relatively to the phantom only (simulated co-registration technique). The phantom grid contained a total of 2002 vertices or control points that were used in the assessment of volumetric geometric distortion for all scans. Results: Volumetric mean absolute spatial deviations relatively to the frame localizer markers for 1.5 and 3 Tesla machine were: 1.39 ± 0.15 and 1.63 ± 0.28 mm with max errors of 1.86 and 2.65 mm correspondingly. Mean 2D errors from the Gamma Plan were 0.3 and 1.0 mm. For simulated co-registration technique the volumetric mean absolute spatial deviations relatively to the phantom for 1.5 and 3 Tesla machine were: 0.36 ± 0.08 and 0.62 ± 0.13 mm with max errors of 0.57 and 1.22 mm correspondingly. Conclusion: Volumetric spatial distortions are lower for 1.5 Tesla versus 3 Tesla MRI machines localized with markers on frames and significantly lower for co-registration techniques with no frame localization. The results show the advantage of using co-registration technique for minimizing MRI volumetric spatial distortions which can be especially important for steep dose gradient fields typically used in Gamma Knife radiosurgery. Consultant for Elekta AB.

  9. Dobutamine stress cardiovascular magnetic resonance at 3 Tesla

    Directory of Open Access Journals (Sweden)

    Klein C

    2008-10-01

    Full Text Available Abstract Purpose The assessment of inducible wall motion abnormalities during high-dose dobutamine-stress cardiovascular magnetic resonance (DCMR is well established for the identification of myocardial ischemia at 1.5 Tesla. Its feasibility at higher field strengths has not been reported. The present study was performed to prospectively determine the feasibility and diagnostic accuracy of DCMR at 3 Tesla for depicting hemodynamically significant coronary artery stenosis (≥ 50% diameter stenosis in patients with suspected or known coronary artery disease (CAD. Materials and methods Thirty consecutive patients (6 women (66 ± 9.3 years were scheduled for DCMR between January and May 2007 for detection of coronary artery disease. Patients were examined with a Philips Achieva 3 Tesla system (Philips Healthcare, Best, The Netherlands, using a spoiled gradient echo cine sequence. Technical parameters were: spatial resolution 2 × 2 × 8 mm3, 30 heart phases, spoiled gradient echo TR/TE: 4.5/2.6 msec, flip angle 15°. Images were acquired at rest and stress in accordance with a standardized high-dose dobutamine-atropine protocol during short breath-holds in three short and three long-axis views. Dobutamine was administered using a standard protocol (10 μg increments every 3 minutes up to 40 μg dobutamine/kg body weight/minute plus atropine if required to reach target heart rate. The study protocol included administration of 0.1 mmol/kg/body weight Gd-DTPA before the cine images at rest were acquired to improve the image quality. The examination was terminated if new or worsening wall-motion abnormalities or chest pain occurred or when > 85% of age-predicted maximum heart rate was reached. Myocardial ischemia was defined as new onset of wall-motion abnormality in at least one segment. In addition, late gadolinium enhancement (LGE was performed. Images were evaluated by two blinded readers. Diagnostic accuracy was determined with coronary

  10. New Tesla-Experiment; Neue Tesla-Experimente

    Energy Technology Data Exchange (ETDEWEB)

    Wahl, Guenter; Harthun, Norbert

    2010-07-01

    Mysterious Teslar wave, microwave and scalar wave generators are presented, as well as exotic Star Wars experiments like mass accelerators and plasma guns. The third section describes, among others, a tube-driven Tesla generator with 50 cm streamers. The reader will also find a catalogue of Messrs. Information Unlimited, USA, who are providers of many of the kits, circuiting diagrams and apparatuses presented here. Main topic in this issue is wireless energy transfer and telecommunication engineering.(orig./GL)

  11. Tesla the life and times of an electric messiah

    CERN Document Server

    Cawthorne, Nigel

    2014-01-01

    Despite being incredibly popular during his time, Nikola Tesla today remains largely overlooked among lists of the greatest inventors and scientists of the modern era.  Thomas Edison gets all the glory for discovering the light bulb, but it was his one time assistant and life long arch nemesis, Tesla, who made the breakthrough in alternating current technology.  Edison and Tesla carried on a bitter feud for years, but it was Tesla's AC generators that illuminated the 1893 World's Fair in Chicago; the first time that an event of such magnitude had ever taken place under artificial light.  Today, all homes and electrical appliances run on Tesla's AC current.Born in Croatia in 1856, Tesla spoke eight languages and as well as almost single handedly developing household electricity.  During his life, he patented more than 700 inventions.  He invented electrical generators, FM radio, remote control robots, spark plugs and fluorescent lights.  He had a photographic memory and did advanced calculus and physic...

  12. TeSLA pilot 2 pedagogical & quality aspects

    OpenAIRE

    Janssen, José

    2018-01-01

    Presentation given at the TeSLA project meeting at the Open University of the Netherlands, addressing pedagogical aspects of pilot 2 and clarification of the scope and limitations of the TeSLA instruments with respect to pedagogy, assessment activity and type of academic dishonesty.

  13. Design considerations and analysis of potential applications of a high power ultraviolet FEL at the TESLA test facility at DESY

    International Nuclear Information System (INIS)

    Pagani, C.; Saldin, E.L.; Schneidmiller, E.A.; Yurkov, M.V.

    1999-01-01

    A possibility of constructing a high power ultraviolet free electron laser at the TESLA test facility at DESY is discussed. The proposed facility consists of a tunable master oscillator (P av ∼10 mW, P peak ∼10 kW, λ≅200-350 nm) and an FEL amplifier with a tapered undulator. The average and peak radiation power at the exit of the FEL amplifier is about 7 kW and 220 GW, respectively. Installation of such a facility can significantly extend scientific potential of the TESLA test facility. The UV free electron laser can be used to construct a polarized, monochromatic gamma-source with the ultimate yield up to 10 12 gamma-quanta per second and the maximal energy of about 100 MeV. An intensive gamma-source can also form the base for constructing the test facility for the TESLA positron generation system. Another accelerator application of the proposed facility is verification of the main technical solutions for the laser and the optical system to be used in the gamma-gamma option of the TESLA collider. A high average power UV laser is also promising for industrial applications

  14. Report on the TESLA engineering study/review

    Energy Technology Data Exchange (ETDEWEB)

    C. Boffo et al.

    2002-07-18

    A team from Argonne National Lab, Cornell, Fermilab, Jefferson Lab, and SLAC has studied the TESLA TDR and its associated cost and manpower estimates, concentrating on the five largest cost sub-systems (Main Linac Modules, Main Linac RF Systems, Civil Engineering, Machine Infrastructure, and XFEL Incremental). These elements were concerned mainly with providing energy reach. We did not study the lower cost, but still technically challenging elements providing luminosity and physics capability, namely damping rings, beam delivery system, beam injection system, positron production, polarized beams, etc. The study did not attempt to validate the TDR cost estimates, but rather its purpose was to understand the technology and status of the large cost items, and the methodology by which their estimated cost was determined. In addition, topics of project oversight were studied.

  15. Emittance damping considerations for TESLA

    International Nuclear Information System (INIS)

    Floettmann, K.; Rossbach, J.

    1993-03-01

    Two schemes are considered to avoid very large damping rings for TESLA. The first (by K.F.) makes use of the linac tunnel to accomodate most of the damping 'ring' structure, which is, in fact, not a ring any more but a long linear structure with two small bends at each of its ends ('dog-bone'). The other scheme (by J.R.) is based on a positron (or electron, respectively) recycling scheme. It makes use of the specific TESLA property, that the full bunch train is much longer (240 km) than the linac length. The spent beams are recycled seven times after interaction, thus reducing the number of bunches to be stored in the damping ring by a factor of eight. Ultimately, this scheme can be used to operate TESLA in a storage ring mode ('storage linac'), with no damping ring at all. Finally, a combination of both schemes is considered. (orig.)

  16. Extension of TFTR operations to higher toroidal field levels

    International Nuclear Information System (INIS)

    Woolley, R.D.

    1995-01-01

    For the past year, TFTR has sometimes operated at extended toroidal field (TF) levels. The extension to 5.6 Tesla (79 kA) was crucial for TFTR's November 1994 10.7 MW DT fusion power record. The extension to 6.0 Tesla (85 kA) was commissioned on 9 September 1995. There are several reasons that one could expect the TF coils to survive the higher stresses that develop at higher fields. They were designed to operate at 5.2 Tesla with a vertical field of 0.5 Tesla, whereas the actual vertical field needed for the plasma does not exceed 0.35 Tesla. Their design specification explicitly required they survive some pulses at 6.0 Tesla. TF coil mechanical analysis computer models available during coil design were crude, leading to conservative design. And design analyses also had to consider worst-case misoperations that TFTR's real time Coil Protection Calculators (CPCs) now positively prevent from occurring

  17. Assessment of MRI Issues at 3 Tesla for a New Metallic Tissue Marker

    Science.gov (United States)

    Cronenweth, Charlotte M.; Shellock, Frank G.

    2015-01-01

    Purpose. To assess the MRI issues at 3 Tesla for a metallic tissue marker used to localize removal areas of tissue abnormalities. Materials and Methods. A newly designed, metallic tissue marker (Achieve Marker, CareFusion, Vernon Hills, IL) used to mark biopsy sites, particularly in breasts, was assessed for MRI issues which included standardized tests to determine magnetic field interactions (i.e., translational attraction and torque), MRI-related heating, and artifacts at 3 Tesla. Temperature changes were determined for the marker using a gelled-saline-filled phantom. MRI was performed at a relatively high specific absorption rate (whole body averaged SAR, 2.9-W/kg). MRI artifacts were evaluated using T1-weighted, spin echo and gradient echo pulse sequences. Results. The marker displayed minimal magnetic field interactions (2-degree deflection angle and no torque). MRI-related heating was only 0.1°C above background heating (i.e., the heating without the tissue marker present). Artifacts seen as localized signal loss were relatively small in relation to the size and shape of the marker. Conclusions. Based on the findings, the new metallic tissue marker is acceptable or “MR Conditional” (using current labeling terminology) for a patient undergoing an MRI procedure at 3 Tesla or less. PMID:26266051

  18. Magnetic-field dependence of the signal of a uranium-scintillator calorimeter

    International Nuclear Information System (INIS)

    Bruehl, S.

    1991-11-01

    The magnetic-field dependence of the signal from 3 GeV electrons and the signal from the uranium radioactivity of a uranium-SCSN-38 test calorimeter was studied with the three in the ZEUS calorimeter implemented uranium-plate coatings 0.2 mm V2A, 0.4 mm V2A, and 0.2 mm V2A and 0.2 mm magnetic C10 in two field directions with fields between 0.01 and 1.4 tesla. In fields oriented parallel to the calorimeter axis uranium and particle signal behave equally except for the case, in which V2A and C10 are applied. At 0.01 tesla the particle signal varies by 1% and the uranium signal by 1.5%. Both signals remain up to 0.1 tesla on this level and increase from this magnetic field. The variation reaches at 1 tesla 4.5% for the particle and 6% for the uranium signal. In the application of V2A and C10 no variation of the particle signal is to be recognized within the errors, while the uranium signal increases monotoneously from 0 to 1.5%. In perpendicularly to the calorimeter axis oriented fields from ≅ 0.3 tesla a different development in the particle and uranium signal occurs. Up to this fields the behaviour of particle and uranium signal is identical with the behaviour in the other field direction. In the application of V2A and C10 the particle respectively the uranium signal increases from 0 at 0.01 tesla to 1% respectively 1.5% at 0.03 tesla. Thereafter the plateau up to 0.1 tesla with the subsequent increasement follows. Independently on the uranium-plate coating the increasement of the uranium signal decreases from 0.3 tesla, reaches at 0.5 tesla a maximum of 3 to 4% and decreases thereafter to 1% at 1 tesla. The particle signal increases as in the other field direction and reaches a signal variation of 7% at 1 tesla. The results are used in the regardment of the magnetic-field effects on the calibration of the ZEUS calorimeter. (orig.) [de

  19. Voltage distribution in tapered winding of tesla-transformer during discharge process of PFL

    International Nuclear Information System (INIS)

    Xin Jiaqi; Chang Anbi; Li Mingjia; Kang Qiang

    2007-01-01

    The operation principle of integral construction of Tesla transformer and PFL was investigated in Tesla-transformer-type accelerator. Experiment was carried out on Tesla transformer's secondary winding to study the impulse voltage distribution while PFL was discharging. The regularities of turn-ground voltage distribution and interturn voltage distribution were summarized. Voltage distribution within PFL was calculated and it was compared with the experimental result. Structural winding of parallel coils in the head, parallel coils in the end and shading ring were used to improve voltage distribution and that was testified by experiment. The results indicate that taper winding doesn't effect electric field within PFL, the turn-ground voltage appears linearly, the interturn voltage fluctuates seriously and it is the biggest in head of winding. The three optimized methods help to depress oscillation, the structural winding of parallel coils in the head decreases the interturn voltage in head of winding remark-ably and the parallel coils in the end decrease the interturn voltage in the end. (authors)

  20. A review of the safety implications of magnetic resonance imaging at field strengths of 3 Tesla and above

    International Nuclear Information System (INIS)

    Crook, Neil; Robinson, Leslie

    2009-01-01

    Rationale: Diagnostic imaging is being driven by technological developments particularly so in the field of Magnetic Resonance Imaging (MRI). Electromagnetic fields used to produce images are becoming much stronger and switched more rapidly and it is essential that safety advice remains appropriate and current. Using a systematic methodology, this review aims to identify the clinical safety implications in performing MRI at field strengths of 3 Tesla (T) and above and determine whether the current clinical safety guidelines are appropriate. Method: References were sourced from The Cochrane Library, Centre for Reviews and Dissemination Science Direct, PubMed and Google Scholar. Related websites searched included The British Institute of Radiology, Society of Radiographers, Royal College of Radiologists, The Institution of Engineering and Technology, IMRSER (Institute for Magnetic Resonance Safety, Education, and Research), MagNet (NHS PASA). References supplied in retrieved papers were also checked for potential relevance. The use of consistent search terminology and inclusion and exclusion criteria ensured quality and provided rigour to conclusions drawn. Conclusion: According to the literature retrieved, the current body of knowledge has allowed safety guidelines to be established for patient safety and these are both appropriate and valid at field strengths of 3 T.

  1. Tesla Coil Theoretical Model and its Experimental Verification

    OpenAIRE

    Voitkans Janis; Voitkans Arnis

    2014-01-01

    In this paper a theoretical model of Tesla coil operation is proposed. Tesla coil is described as a long line with distributed parameters in a single-wire form, where the line voltage is measured across electrically neutral space. By applying the principle of equivalence of single-wire and two-wire schemes an equivalent two-wire scheme can be found for a single-wire scheme and the already known long line theory can be applied to the Tesla coil. A new method of multiple re...

  2. Multicontrast-weighted magnetic resonance imaging of atherosclerotic plaques at 3.0 and 1.5 Tesla: ex-vivo comparison with histopathologic correlation

    International Nuclear Information System (INIS)

    Koops, Andreas; Ittrich, Harald; Priest, Andrew; Stork, Alexander; Adam, Gerhard; Weber, Christoph; Petri, Susan; Lockemann, Ute

    2007-01-01

    The purpose was to analyze magnetic resonance (MR) plaque imaging at 3.0 Tesla and 1.5 Tesla in correlation with histopathology. MR imaging (MRI) of the abdominal aorta and femoral artery was performed on seven corpses using T1-weighted, T2-weighted, and PD-weighted sequences at 3.0 and 1.5 Tesla. Cross-sectional images at the branching of the inferior mesenteric artery and the profunda femoris were rated with respect to image quality. Corresponding cross sections of the imaged vessels were obtained at autopsy. The atherosclerotic plaques in the histological slides and MR images were classified according to the American Heart Association (AHA) and analyzed for differences. MRI at 3.0 Tesla offered superior depiction of arterial wall composition in all contrast weightings, rated best for T2-weighted images. Comparing for field strength, the highest differences were observed in T1-weighted and T2-weighted techniques (both P≤0.001), with still significant differences in PD-weighted sequence (P≤0.005). The majority of plaques were histologically classified as calcified plaques. In up to 21% of the cases, MRI at both field strengths detected signal loss characteristic of calcification although calcified plaque was absent in histology. MRI at 3.0 Tesla offers superior plaque imaging quality compared with 1.5 Tesla, but further work is necessary to determine whether this translates in superior diagnostic accuracy. (orig.)

  3. Seeing Like a Tesla: How Can We Anticipate Self-Driving Worlds?

    Directory of Open Access Journals (Sweden)

    Jack Stilgoe

    2018-02-01

    Full Text Available In the last five years, investment and innovation in self-driving cars has accelerated dramatically. Automotive autonomy, once seen as impossible, is now sold as inevitable. Much of the governance discussion has centred on risk: will the cars be safer than their human-controlled counterparts? As with conventional cars, harder long-term questions relate to the future worlds that self-driving technologies might enable or even demand. The vision of an autonomous vehicle – able to navigate the world’s complexity using only its sensors and processors – on offer from companies like Tesla is intentionally misleading. So-called “autonomous” vehicles will depend upon webs of social and technical connectivity. For their purported benefits to be realised, infrastructures that were designed around humans will need to be upgraded in order to become machine-readable. It is vital to anticipate the politics of self-driving worlds in order to avoid exacerbating the inequalities that have emerged around conventional cars. Rather than being dazzled by the Tesla view, policymakers should start seeing like a city, from multiple perspectives. Good governance for self-driving cars means democratising experimentation and creating genuine collaboration between companies and local governments.

  4. Nikola Tesla, the Ether and his Telautomaton

    Science.gov (United States)

    Milar, Kendall

    2014-03-01

    In the nineteenth century physicists' understanding of the ether changed dramatically. New developments in thermodynamics, energy physics, and electricity and magnetism dictated new properties of the ether. These have traditionally been examined from the perspective of the scientists re-conceptualizing the ether. However Nikola Tesla, a prolific inventor and writer, presents a different picture of nineteenth century physics. Alongside the displays that showcased his inventions he presented alternative interpretations of physical, physiological and even psychical research. This is particularly evident in his telautomaton, a radio remote controlled boat. This invention and Tesla's descriptions of it showcase some of his novel interpretations of physical theories. He offered a perspective on nineteenth century physics that focused on practical application instead of experiment. Sometimes the understanding of physical theories that Tesla reached was counterproductive to his own inventive work; other times he offered new insights. Tesla's utilitarian interpretation of physical theories suggests a more scientifically curious and invested inventor than previously described and a connection between the scientific and inventive communities.

  5. TESLA-N electron scattering with polarized targets at TESLA

    International Nuclear Information System (INIS)

    Korotokov, V.

    2001-01-01

    Measurements of polarized eN scattering can be realized at the TESLA linear collider facility at DESY with luminosities that are about two orders of magnitude higher than those expected for other experiments at comparable energies. A large variety of polarized parton distribution and fragmentation functions can be determined with unprecedented accuracy, many of them for the first time

  6. Implementation of fast macromolecular proton fraction mapping on 1.5 and 3 Tesla clinical MRI scanners: preliminary experience

    Science.gov (United States)

    Yarnykh, V.; Korostyshevskaya, A.

    2017-08-01

    Macromolecular proton fraction (MPF) is a biophysical parameter describing the amount of macromolecular protons involved into magnetization exchange with water protons in tissues. MPF represents a significant interest as a magnetic resonance imaging (MRI) biomarker of myelin for clinical applications. A recent fast MPF mapping method enabled clinical translation of MPF measurements due to time-efficient acquisition based on the single-point constrained fit algorithm. However, previous MPF mapping applications utilized only 3 Tesla MRI scanners and modified pulse sequences, which are not commonly available. This study aimed to test the feasibility of MPF mapping implementation on a 1.5 Tesla clinical scanner using standard manufacturer’s sequences and compare the performance of this method between 1.5 and 3 Tesla scanners. MPF mapping was implemented on 1.5 and 3 Tesla MRI units of one manufacturer with either optimized custom-written or standard product pulse sequences. Whole-brain three-dimensional MPF maps obtained from a single volunteer were compared between field strengths and implementation options. MPF maps demonstrated similar quality at both field strengths. MPF values in segmented brain tissues and specific anatomic regions appeared in close agreement. This experiment demonstrates the feasibility of fast MPF mapping using standard sequences on 1.5 T and 3 T clinical scanners.

  7. The TESLA physics program

    CERN Document Server

    Behnke, T

    2002-01-01

    The TESLA accelerator concept is based on superconducting cavities, which are operated at comparatively low frequencies (L-Band, 1.3 GHz) . Superconducting cavities in connection with the low frequency offer a number of significant advantages. Because the power dissipation in the superconducting cavity walls is very small, the accelerating field can be produced with long, low peak-power RF pulses. Thus the total power consumption of the accelerator can be kept at an acceptable limit, while still maintaining a high current and a long bunch train in the machine. In fact it is possible to use a long RF pulse (of 1 ms length) and large inter-bunch spacing within one pulse (337 ns at E/sub cms/ = 500 GeV). This allows collisions with zero- crossing angle at the experiment, and gives enough time between two bunches to operate a fast feedback system to maintain stable collisions. Even more important, the relatively low RF frequency results in significant smaller wake field effects than at machine operating at larger...

  8. Tesla-transformer-type electron beam accelerator

    International Nuclear Information System (INIS)

    Liu Jinliang; Zhong Huihuang; Tan Qimei; Li Chuanlu; Zhang Jiande

    2002-01-01

    An electron-beam Tesla-transformer accelerator is described. It consists of the primary storage energy system. Tesla transformer, oil Blumlein pulse form line, and the vacuum diode. The experiments of initial stage showed that diode voltage rises up to about 500 kV with an input of 20 kV and the maximum electron-beam current is about 9 kA, the pulse width is about 50 ns. This device can operate stably and be set up easily

  9. Achievement of 35 MV/m in the superconducting nine-cell cavities for TESLA

    International Nuclear Information System (INIS)

    Lilje, L.; Kostin, D.; Matheisen, A.; Moeller, W.D.; Proch, D.; Reschke, D.; Simrock, S.; Twarowski, K.; Kako, E.; Saito, K.; Schmueser, P.; Suzuki, T.

    2004-01-01

    The tera electronvolt superconducting linear accelerator TESLA is the only linear electron-positron collider project based on superconductor technology for particle acceleration. In the first stage with 500 GeV center-of-mass energy an accelerating field of 23.4 MV/m is needed in the superconducting niobium cavities which are operated at a temperature of 2 K and a quality factor Q 0 of 10 10 . This performance has been reliably achieved in the cavities of the TESLA test facility (TTF) accelerator. The upgrade of TESLA to 800 GeV requires accelerating gradients of 35 MV/m. Using an improved cavity treatment by electrolytic polishing it has been possible to raise the gradient to 35 - 43 MV/m in single cell resonators. Here we report on the successful transfer of the electropolishing technique to multi-cell cavities. Presently four nine-cell cavities have achieved 35 MV/m at Q 0 ≥ 5 x 10 9 , and a fifth cavity could be excited to 39 MV/m. In two high-power tests it could be verified that EP-cavities preserve their excellent performance after welding into the helium cryostat and assembly of the high-power coupler. One cavity has been operated for 1100 hours at the TESLA-800 gradient of 35 MV/m and 57 hours at 36 MV/m without loss in performance. (orig.)

  10. How Much Tesla Is Too Much?

    International Nuclear Information System (INIS)

    Monu, U.V.J.

    2015-01-01

    There are 7 Tesla (T) scanners operate in up to 35 research clinics worldwide. Currently 11T, 9T, 7T and 4T MRI in research facilities all over the world. The more powerful the magnet -the better the images, the faster the imaging time and the more patient put through. 10 -12 T seem to be the upper limit for current technology. The FDA has limited the power of the MRI for clinical use to 8T. Higher Field MRI Scanner-Advantages include Higher Field MRI Scanner, higher contrast to noise, higher spatial resolution and Images can be acquired at faster times. UltraHigh Field Imaging Advantageous in Sports medicine type patients with injury to tendons, ligaments and cartilage. Disadvantages of telsa to Safety Issues include Specific Absorption Rate (SARs) issues, Increased heating of tissues, Becomes an issue when imaging large structures, not a real problem in MSK except for spine imaging and Most units will adjust to approved parameters before scanning

  11. Contribution to study and realization of 20-Tesla superconducting magnet

    International Nuclear Information System (INIS)

    Marty, J.

    1981-11-01

    This work is mainly concerned with 20 Tesla induction production study. This magnetic induction should be produced by associating a series of coils using high critical field commercial: superconductors to the 10 Tesla magnet (diameter: 300; let's call it 10-300 magnet). The operation temperature lowering from 4,2 0 K to 1,8 0 K should effectively lead to much higher inductions (with equal effective diameter) than the greatest performances nowadays realized at 4,2 0 K temperature. To this performance augmentation is associated a more important energy density augmentation. This leads to the necessity of the knowledge of the superconducting material physical properties. They are studied in this report. Following, different methodes of magnet calculations are described: problems related to mechanical constraints, protection and stability must be known. Finally, some coils of the 10-300 magnet are presented together with their realization [fr

  12. Quantification of susceptibility artifacts in 0.5, 1.5 and 3.0 tesla magnetic resonance imaging produced from various biomaterials

    International Nuclear Information System (INIS)

    Matsuura, Hideki

    2002-01-01

    Several studies have examined various biomaterials to minimize susceptibility artifacts using low magnetic fields such as 0.5 Tesla or 1.5 Tesla, but no work has been done with high magnetic field. The purpose of the present study was to quantify the susceptibility artifacts produced from various biomaterials for neurosurgical implants in 0.5, 1.5 and 3.0 Tesla MR scanner. We performed MR imaging of six kinds of ceramics, two kinds of Co-based alloys with different combination, pure titanium, titanium alloy and stainless steel. Images were transferred to computer and analyzed. On all biomaterials, susceptibility artifacts developed parallel to the direction of the main magnetic field at both ends. Ceramics had considerably smaller artifact diameter compared with other biomaterials. Among ceramics, the artifact diameter of zirconia was the smallest. There were few differences between the artifact diameter of pure titanium and that of titanium alloy. Ceramics are promising biomaterials for minimum artifacts in higher field MR system. Although it is necessary to carry out degradation tests or retention force evaluation of the ceramics, we considered the ceramics are the most suitable biomaterials for the artifacts in MR imaging. (author)

  13. MR imaging of the prostate at 3 Tesla: comparison of an external phased-array coil to imaging with an endorectal coil at 1.5 Tesla.

    Science.gov (United States)

    Sosna, Jacob; Pedrosa, Ivan; Dewolf, William C; Mahallati, Houman; Lenkinski, Robert E; Rofsky, Neil M

    2004-08-01

    To qualitatively compare the image quality of torso phased-array 3-Tesla (3T) imaging of the prostate with that of endorectal 1.5-Tesla imaging. Twenty cases of torso phased-array prostate imaging performed at 3-Tesla with FSE T2 weighted images were evaluated by two readers independently for visualization of the posterior border (PB), seminal vesicles (SV), neurovascular bundles (NVB), and image quality rating (IQR). Studies were performed at large fields of view(FOV) (25 cm) (14 cases) (3TL) and smaller FOV (14 cm) (19 cases) (3TS). A comparison was made to 20 consecutive cases of 1.5-T endorectal evaluation performed during the same time period.Results. 3TL produced a significantly better image quality compared with the small FOV for PB (P = .0001), SV (P =.0001), and IQR (P = .0001). There was a marginally significant difference within the NVB category (P = .0535). 3TL produced an image of similar quality to image quality at 1.5 T for PB (P = .3893), SV (P = .8680), NB (P = .2684), and IQR (P = .8599). Prostate image quality at 3T with a torso phased-array coil can be comparable with that of endorectal 1.5-T imaging. These findings suggest that additional options are now available for magnetic resonance imaging of the prostate gland.

  14. Advanced MR methods at ultra-high field (7 Tesla) for clinical musculoskeletal applications

    Energy Technology Data Exchange (ETDEWEB)

    Trattnig, Siegfried [Medical University of Vienna/Vienna General Hospital, MR Centre - High Field MR, Department of Radiology, Vienna (Austria); Ludwig Boltzmann Institute for Experimental and Clinical Traumatology, Austrian Cluster for Tissue Regeneration, Vienna (Austria); Zbyn, Stefan; Schmitt, Benjamin; Friedrich, Klaus; Bogner, Wolfgang [Medical University of Vienna/Vienna General Hospital, MR Centre - High Field MR, Department of Radiology, Vienna (Austria); Juras, Vladimir; Szomolanyi, Pavol [Medical University of Vienna/Vienna General Hospital, MR Centre - High Field MR, Department of Radiology, Vienna (Austria); Slovak Academy of Sciences, Department of Imaging Methods, Institute of Measurement Science, Bratislava (Slovakia)

    2012-11-15

    This article provides an overview of the initial clinical results of musculoskeletal studies performed at 7 Tesla, with special focus on sodium imaging, new techniques such as chemical exchange saturation transfer (CEST) and T2* imaging, and multinuclear MR spectroscopy. Sodium imaging was clinically used at 7 T in the evaluation of patients after cartilage repair procedures because it enables the GAG content to be monitored over time. Sodium imaging and T2* mapping allow insights into the ultra-structural composition of the Achilles tendon and help detect early disease. Chemical exchange saturation transfer was, for the first time, successfully applied in the clinical set-up at 7 T in patients after cartilage repair surgery. The potential of phosphorus MR spectroscopy in muscle was demonstrated in a comparison study between 3 and 7 T, with higher spectral resolution and significantly shorter data acquisition times at 7 T. These initial clinical studies demonstrate the potential of ultra-high field MR at 7 T, with the advantage of significantly improved sensitivity for other nuclei, such as {sup 23}Na (sodium) and {sup 31}P (phosphorus). The application of non-proton imaging and spectroscopy provides new insights into normal and abnormal physiology of musculoskeletal tissues, particularly cartilage, tendons, and muscles. (orig.)

  15. Breath-hold imaging of the coronary arteries using Quiescent-Interval Slice-Selective (QISS) magnetic resonance angiography: pilot study at 1.5 Tesla and 3 Tesla.

    Science.gov (United States)

    Edelman, Robert R; Giri, S; Pursnani, A; Botelho, M P F; Li, W; Koktzoglou, I

    2015-11-23

    Coronary magnetic resonance angiography (MRA) is usually obtained with a free-breathing navigator-gated 3D acquisition. Our aim was to develop an alternative breath-hold approach that would allow the coronary arteries to be evaluated in a much shorter time and without risk of degradation by respiratory motion artifacts. For this purpose, we implemented a breath-hold, non-contrast-enhanced, quiescent-interval slice-selective (QISS) 2D technique. Sequence performance was compared at 1.5 and 3 Tesla using both radial and Cartesian k-space trajectories. The left coronary circulation was imaged in six healthy subjects and two patients with coronary artery disease. Breath-hold QISS was compared with T2-prepared 2D balanced steady-state free-precession (bSSFP) and free-breathing, navigator-gated 3D bSSFP. Approximately 10 2.1-mm thick slices were acquired in a single ~20-s breath-hold using two-shot QISS. QISS contrast-to-noise ratio (CNR) was 1.5-fold higher at 3 Tesla than at 1.5 Tesla. Cartesian QISS provided the best coronary-to-myocardium CNR, whereas radial QISS provided the sharpest coronary images. QISS image quality exceeded that of free-breathing 3D coronary MRA with few artifacts at either field strength. Compared with T2-prepared 2D bSSFP, multi-slice capability was not restricted by the specific absorption rate at 3 Tesla and pericardial fluid signal was better suppressed. In addition to depicting the coronary arteries, QISS could image intra-cardiac structures, pericardium, and the aortic root in arbitrary slice orientations. Breath-hold QISS is a simple, versatile, and time-efficient method for coronary MRA that provides excellent image quality at both 1.5 and 3 Tesla. Image quality exceeded that of free-breathing, navigator-gated 3D MRA in a much shorter scan time. QISS also allowed rapid multi-slice bright-blood, diastolic phase imaging of the heart, which may have complementary value to multi-phase cine imaging. We conclude that, with further clinical

  16. Cavity parameters identification for TESLA control system development

    Energy Technology Data Exchange (ETDEWEB)

    Czarski, T.; Pozniak, K.T.; Romaniuk, R.S. [Warsaw Univ. of Technology (Poland). ELHEP Lab., ISE; Simrock, S. [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany)

    2005-07-01

    The control system modeling for the TESLA - TeV-Energy Superconducting Linear Accelerator project has been developed for the efficient stabilization of the pulsed, accelerating EM field of the resonator. The cavity parameters identification is an essential task for the comprehensive control algorithm. The TESLA cavity simulator has been successfully implemented by applying very high speed FPGA - Field Programmable Gate Array technology. The electromechanical model of the cavity resonator includes the basic features - Lorentz force detuning and beam loading. The parameters identification bases on the electrical model of the cavity. The model is represented by the state space equation for the envelope of the cavity voltage driven by the current generator and the beam loading. For a given model structure, the over-determined matrix equation is created covering the long enough measurement range with the solution according to the least squares method. A low degree polynomial approximation is applied to estimate the time-varying cavity detuning during the pulse. The measurement channel distortion is considered, leading to the external cavity model seen by the controller. The comprehensive algorithm of the cavity parameters identification has been implemented in the Matlab system with different modes of the operation. Some experimental results have been presented for different cavity operational conditions. The following considerations have lead to the synthesis of the efficient algorithm for the cavity control system predicted for the potential FPGA technology implementation. (orig.)

  17. Cavity parameters identification for TESLA control system development

    International Nuclear Information System (INIS)

    Czarski, T.; Pozniak, K.T.; Romaniuk, R.S.

    2005-01-01

    The control system modeling for the TESLA - TeV-Energy Superconducting Linear Accelerator project has been developed for the efficient stabilization of the pulsed, accelerating EM field of the resonator. The cavity parameters identification is an essential task for the comprehensive control algorithm. The TESLA cavity simulator has been successfully implemented by applying very high speed FPGA - Field Programmable Gate Array technology. The electromechanical model of the cavity resonator includes the basic features - Lorentz force detuning and beam loading. The parameters identification bases on the electrical model of the cavity. The model is represented by the state space equation for the envelope of the cavity voltage driven by the current generator and the beam loading. For a given model structure, the over-determined matrix equation is created covering the long enough measurement range with the solution according to the least squares method. A low degree polynomial approximation is applied to estimate the time-varying cavity detuning during the pulse. The measurement channel distortion is considered, leading to the external cavity model seen by the controller. The comprehensive algorithm of the cavity parameters identification has been implemented in the Matlab system with different modes of the operation. Some experimental results have been presented for different cavity operational conditions. The following considerations have lead to the synthesis of the efficient algorithm for the cavity control system predicted for the potential FPGA technology implementation. (orig.)

  18. Spatial Distortion in MRI-Guided Stereotactic Procedures: Evaluation in 1.5-, 3- and 7-Tesla MRI Scanners.

    Science.gov (United States)

    Neumann, Jan-Oliver; Giese, Henrik; Biller, Armin; Nagel, Armin M; Kiening, Karl

    2015-01-01

    Magnetic resonance imaging (MRI) is replacing computed tomography (CT) as the main imaging modality for stereotactic transformations. MRI is prone to spatial distortion artifacts, which can lead to inaccuracy in stereotactic procedures. Modern MRI systems provide distortion correction algorithms that may ameliorate this problem. This study investigates the different options of distortion correction using standard 1.5-, 3- and 7-tesla MRI scanners. A phantom was mounted on a stereotactic frame. One CT scan and three MRI scans were performed. At all three field strengths, two 3-dimensional sequences, volumetric interpolated breath-hold examination (VIBE) and magnetization-prepared rapid acquisition with gradient echo, were acquired, and automatic distortion correction was performed. Global stereotactic transformation of all 13 datasets was performed and two stereotactic planning workflows (MRI only vs. CT/MR image fusion) were subsequently analysed. Distortion correction on the 1.5- and 3-tesla scanners caused a considerable reduction in positional error. The effect was more pronounced when using the VIBE sequences. By using co-registration (CT/MR image fusion), even a lower positional error could be obtained. In ultra-high-field (7 T) MR imaging, distortion correction introduced even higher errors. However, the accuracy of non-corrected 7-tesla sequences was comparable to CT/MR image fusion 3-tesla imaging. MRI distortion correction algorithms can reduce positional errors by up to 60%. For stereotactic applications of utmost precision, we recommend a co-registration to an additional CT dataset. © 2015 S. Karger AG, Basel.

  19. A new interlock design for the TESLA RF system

    International Nuclear Information System (INIS)

    Leich, H.; Kahl, J.; Choroba, S.; Grevsmuehl, T.; Heidbrook, N.

    2001-01-01

    The RF system for TESLA requires a comprehensive interlock system. Usually interlock systems are organized in a hierarchical way. In order to react to different fault conditions in a fast and flexible manner a nonhierarchical organization seems to be the better solution. At the TESLA Test Facility (TTF) at DESY the authors will install a nonhierarchical interlock system that is based on user designed reprogrammable gate-arrays (FPGA's) which incorporate an embedded microcontroller system. This system could be used later for the TESLA linear collider replacing a strictly hierarchical design

  20. Living laboratory for Nikola Tesla. Living laboratories, Tesla, Second Life, sustainable construction technologies and renewable energy sources; Wohnlabor fuer Nikola Tesla. Ueber Wohnlabors, Tesla, Second Life, nachhaltige Bautechnologien und erneuerbare Energie

    Energy Technology Data Exchange (ETDEWEB)

    Redi, Ivan; Redi, Andrea; Jovanovic, Branimir (and others)

    2008-07-01

    Adventure is the opposite of conventional teaching. Adventure is the moment when experience alone is not enough. Sometimes, courageous people challenge the nature of things, helping us to get new insights and achieve a new viewpoint. The experience-oriented ''work in progress'' university is an adventure of this kind. The book looks into the Tesla laboratory and the Wardenclyffe Tower, both of which could not be completed for financial reasons, and addresses them from today's state of technology. The conceptional section is based on the ''Tesla doctrine'' which comprises fundamental philosophical statements on civilisatory progress. The book presents the results of the investigation. The 16 architectural projects presented here were developed live on the online platform. Second Life, ORTLOS Sim. (orig.)

  1. Tesla inventor of the electrical age

    CERN Document Server

    Carlson, W Bernard

    2013-01-01

    Nikola Tesla was a major contributor to the electrical revolution that transformed daily life at the turn of the twentieth century. His inventions, patents, and theoretical work formed the basis of modern AC electricity, and contributed to the development of radio and television. Like his competitor Thomas Edison, Tesla was one of America's first celebrity scientists, enjoying the company of New York high society and dazzling the likes of Mark Twain with his electrical demonstrations. An astute self-promoter and gifted showman, he cultivated a public image of the eccentric genius. Even at t

  2. A high-resolution 7-Tesla fMRI dataset from complex natural stimulation with an audio movie.

    Science.gov (United States)

    Hanke, Michael; Baumgartner, Florian J; Ibe, Pierre; Kaule, Falko R; Pollmann, Stefan; Speck, Oliver; Zinke, Wolf; Stadler, Jörg

    2014-01-01

    Here we present a high-resolution functional magnetic resonance (fMRI) dataset - 20 participants recorded at high field strength (7 Tesla) during prolonged stimulation with an auditory feature film ("Forrest Gump"). In addition, a comprehensive set of auxiliary data (T1w, T2w, DTI, susceptibility-weighted image, angiography) as well as measurements to assess technical and physiological noise components have been acquired. An initial analysis confirms that these data can be used to study common and idiosyncratic brain response patterns to complex auditory stimulation. Among the potential uses of this dataset are the study of auditory attention and cognition, language and music perception, and social perception. The auxiliary measurements enable a large variety of additional analysis strategies that relate functional response patterns to structural properties of the brain. Alongside the acquired data, we provide source code and detailed information on all employed procedures - from stimulus creation to data analysis. In order to facilitate replicative and derived works, only free and open-source software was utilized.

  3. Clinical evaluation of cardiovascular disease by gated-MRI (magnetic resonance imaging) in the operating field of 0.35 and 1.5 Tesla

    International Nuclear Information System (INIS)

    Nishimura, Tsunehiko; Naito, Hiroaki; Yamada, Yukinori; Kozuka, Takahiro

    1985-01-01

    To evaluate the clinical usefulness of magnetic resonance imaging (MRI) in the cardiovascular disease, 21 patients were examined using 0.35 and 1.5 Tesla superconductive type (Magnetom, Siemens). In our study, all patients were performed using ECG-gated MRI. Therefore, the cardiac chambers were discriminated clearly from the myocardial wall compared to non-gated MRI. Gated-MRI was performed in 6 normal persons in the operating field at 0.35 and 1.5 Tesla. The image of the latter showed superior than that of the former because of high S/N ratio. In myocardial infarction, infarct area was demonstrated as the wall thinning in 4 of 5 patients. Hypertrophic cardiomyopathy showed thickened left ventricle associated with its narrowed cavity in 7 patients. In the remaining such as congenital and valvular heart disease, global and regional cardiac morphology were assessed noninvasively by gated MRI. In addition, gated MRI was also applied to the diagnosis of peripheral vascular diseases. In dissecting aneurysm, double channels with an intimal flap in the aorta were clearly visualized. And in the aortitis syndrome, aortic dilatation and stenosis were also assessed noninvasively. In conclusion, gated MRI in diagnosing various abnormalities of cardiovascular disease was confirmed. (author)

  4. Blood Flow and Brain Function: Investigations of neurovascular coupling using BOLD fMRI at 7 tesla

    NARCIS (Netherlands)

    Siero, J.C.W.

    2013-01-01

    The advent of ultra high field (7 tesla) MRI systems has opened the possibility to probe biological processes of the human body in great detail. Especially for studying brain function using BOLD fMRI there is a large benefit from the increased magnetic field strength. BOLD fMRI is the working horse

  5. Measurement of the Hall scattering factor in 4H SiC epilayers from 40 K to 290 K and up to magnetic fields of nine Tesla

    Energy Technology Data Exchange (ETDEWEB)

    Rutsch, G. [Pittsburgh Univ., PA (United States). Dept. of Physics and Astronomy]|[Dept. of Electrical Engineering, Univ. of Pittsburgh, PA (United States); Devaty, R.P.; Choyke, W.J. [Pittsburgh Univ., PA (United States). Dept. of Physics and Astronomy; Langer, D.W. [Dept. of Electrical Engineering, Univ. of Pittsburgh, PA (United States); Rowland, L.B. [Northrop Grumman Science and Technology Center, Pittsburgh, PA (United States)

    1998-06-01

    In order to accurately extract material properties from temperature dependent Hall measurements, it is necessary to know the Hall scattering factor (r{sub H}), among other material properties. We present measurements of the Hall scattering factor on nitrogen doped 4H SiC epitaxial layers from 40 K to room temperature in magnetic fields up to 9 Tesla. The measured effective Hall scattering factor varies from 0.91 to 1.21. (orig.) 6 refs.

  6. Instrumentation of the forward region of the TESLA detector

    International Nuclear Information System (INIS)

    Buesser, Karsten

    2004-01-01

    The expected beam-beam interaction at the proposed TESLA electron-positron linear collider has a significant impact on the design of the TESLA detector. Especially the instrumentation of the very forward region down to polar angles below 5 mrad will have to handle an immense background of electrons and positrons adding up to TeVs of energy deposition per bunch crossing. Instrumentation down to small angles is crucial not only for the measurement of the luminosity through Bhabha scattering, but also to maximize the hermeticity of the detector. Additionally these charged particles from beamstrahlung have to be measured as part of the feedback system of the TESLA accelerator and could also be used for beam diagnostics. The present design of the TESLA detector foresees two calorimeters in the forward region whose technologies have to meet the requirements regarding detector resolutions and radiation hardness. (orig.)

  7. Enhanced Energy Density in Permanent Magnets using Controlled High Magnetic Field during Processing

    Energy Technology Data Exchange (ETDEWEB)

    Carter, William G [ORNL; Rios, Orlando [ORNL; Constantinides, Steven [ORNL

    2016-05-05

    This ORNL Manufacturing Demonstraction Facility (MDF) technical collaboration focused on the use of high magnetic field processing (>2Tesla) using energy efficient large bore superconducting magnet technology and high frequency electromagnetics to improve magnet performance and reduce the energy budget associated with Alnico thermal processing. Alnico, alloys containing Al, Ni, Co and Fe, represent a class of functional nanostructured alloys, and show the greatest potential for supplementing or replacing commercial Nd-based rare-earth alloy magnets.

  8. [Nikola Tesla: flashes of inspiration].

    Science.gov (United States)

    Villarejo-Galende, Albero; Herrero-San Martín, Alejandro

    2013-01-16

    Nikola Tesla (1856-1943) was one of the greatest inventors in history and a key player in the revolution that led to the large-scale use of electricity. He also made important contributions to such diverse fields as x-rays, remote control, radio, the theory of consciousness or electromagnetism. In his honour, the international unit of magnetic induction was named after him. Yet, his fame is scarce in comparison with that of other inventors of the time, such as Edison, with whom he had several heated arguments. He was a rather odd, reserved person who lived for his inventions, the ideas for which came to him in moments of inspiration. In his autobiography he relates these flashes with a number of neuropsychiatric manifestations, which can be seen to include migraine auras, synaesthesiae, obsessions and compulsions.

  9. In vitro assessment of MRI issues at 3-Tesla for a breast tissue expander with a remote port.

    Science.gov (United States)

    Linnemeyer, Hannah; Shellock, Frank G; Ahn, Christina Y

    2014-04-01

    A patient with a breast tissue expander may require a diagnostic assessment using magnetic resonance imaging (MRI). To ensure patient safety, this type of implant must undergo in vitro MRI testing using proper techniques. Therefore, this investigation evaluated MRI issues (i.e., magnetic field interactions, heating, and artifacts) at 3-Tesla for a breast tissue expander with a remote port. A breast tissue expander with a remote port (Integra Breast Tissue Expander, Model 3612-06 with Standard Remote Port, PMT Corporation, Chanhassen, MN) underwent evaluation for magnetic field interactions (translational attraction and torque), MRI-related heating, and artifacts using standardized techniques. Heating was evaluated by placing the implant in a gelled-saline-filled phantom and MRI was performed using a transmit/receive RF body coil at an MR system reported, whole body averaged specific absorption rate of 2.9-W/kg. Artifacts were characterized using T1-weighted and GRE pulse sequences. Magnetic field interactions were not substantial and, thus, will not pose a hazard to a patient in a 3-Tesla or less MRI environment. The highest temperature rise was 1.7°C, which is physiologically inconsequential. Artifacts were large in relation to the remote port and metal connector of the implant but will only present problems if the MR imaging area of interest is where these components are located. A patient with this breast tissue expander with a remote port may safely undergo MRI at 3-Tesla or less under the conditions used for this investigation. These findings are the first reported at 3-Tesla for a tissue expander. Copyright © 2014 Elsevier Inc. All rights reserved.

  10. Influence of magnetic fields on the response of a uranium scintillator electromagnetic calorimeter

    International Nuclear Information System (INIS)

    Mainusch, J.; Corriveau, F.; Klanner, R.

    1991-04-01

    The response of a uranium scintillator sampling calorimeter to incident electrons and to the uranium radioactivity was measured in transverse magnetic fields up to 1.4 Tesla. The signal from electrons rises by as much as 9% due to the expected increase in light output of plastic scintillators in magnetic fields. For fields below 0.3 Tesla the response to the uranium radioactivity tracks the electron signal to within about 0.5%. At higher fields it drops sharply, reaching -1.5% at 1.4 Tesla. The consequences for the calibration of the ZEUS uranium scintillator calorimeter are discussed. We found no evidence for a change in the electromagnetic sampling fraction for fields below 0.3 Tesla. (orig.)

  11. Development of a 1.0 MV 100 Hz compact tesla transformer with PFL

    International Nuclear Information System (INIS)

    Kang Qiang; Chang Anbi; Li Mingjia; Meng Fanbao; Su Youbin

    2006-01-01

    The theory and characteristic of a compact Tesla transformer are introduced, and an unitized configuration design is performed for 1.0 MV, 100 Hz Tesla transformer and 40 Ω, 40 ns pulse forming line (PFL). Two coaxial open cores in Tesla transformer serve as the inner and outer conductors of PFL, and a traditional PFL is combined with the Tesla transformer, then the pulse generator can be smaller, more efficient, and more stable. The designed compact Tesla transformer employed in electron beams accelerator CHP01 can charge PFL of 600 pF for 1.3 MV voltage at a single shot, and keep 1.15 MV at 100 Hz repeated rates. Furthermore, a continuance run in 5 seconds is achieved by Tesla transformer under voltage and frequency ratings. (authors)

  12. Nikola Tesla and robotics

    Directory of Open Access Journals (Sweden)

    Vukobratović Miomir

    2006-01-01

    Full Text Available The paper analyzes some of Tesla's works and his most remarkable views concerning the problem of formulating theoretical bases of automatic control. As a tribute to Tesla's work on remote control of automated systems, as well to his (at the time far-seeing visions, special attention is paid to solving complex problem of control and feedback application. A more detailed discussion of the way and origin of formulating theoretical bases of automatic control are given. Besides, in more detail are presented the related pioneering works of Professor Nicholas Bernstein, great Russian physiologist who formulated the basic rules of the self-regulating movements of the man. Bernstein has achievements of highest scientific significance that has been in a direct function of identifying and proving the priority of his pioneering contributions in the domain of feedback, i.e. control and principles of cybernetics.

  13. Intraindividual comparison of image quality in MR urography at 1.5 and 3 Tesla in an animal model

    Energy Technology Data Exchange (ETDEWEB)

    Regier, M.; Adam, G.; Kemper, J. [Klinik und Poliklinik fuer Diagnostische und Interventionelle Radiologie, Universitaetsklinikum Hamburg-Eppendorf (Germany); Nolte-Ernsting, C. [Klinik fuer Diagnostische und Interventionelle Radiologie, Universitaetsklinikum Hamburg-Eppendorf (Germany)

    2008-10-15

    Purpose: experimental evaluation of image quality of the upper urinary tract in MR urography (MRU) at 1.5 and 3 Tesla in a porcine model. Materials and methods: in this study four healthy domestic pigs, weighing between 71 and 80 kg (mean 73.6 kg), were examined with a standard T 1w 3D-GRE and a high-resolution (HR) T 1w 3D-GRE sequence at 1.5 and 3 Tesla. Additionally, at 3 Tesla both sequences were performed with parallel imaging (SENSE factor 2). The MR urographic scans were performed after intravenous injection of gadolinium-DTPA (0.1 mmol/kg body weight (bw)) and low-dose furosemide (0.1 mg/kg bw). Image evaluation was performed by two independent radiologists blinded to sequence parameters and field strength. Image analysis included grading of image quality of the segmented collecting system based on a five-point grading scale regarding anatomical depiction and artifacts observed (1: the majority of the segment (> 50%) was not depicted or was obscured by major artifacts; 5: the segment was visualized without artifacts and had sharply defined borders). Signal-to-noise (SNR) and contrast-to-noise (CNR) ratios were determined. Statistical analysis included {kappa}-statistics, Wilcoxon and paired student t-test. Results: the mean scores for MR urographies at 1.5 Tesla were 2.83 for the 3D-GRE and 3.48 for the HR 3D-GRE sequence. Significantly higher values were determined using the corresponding sequences at 3 Tesla, averaging 3.19 for the 3D-GRE (p = 0.047) and 3.92 for the HR 3D-GRE (p = 0.023) sequence. Delineation of the pelvicaliceal system was rated significantly higher at 3 Tesla compared to 1.5 Tesla (3D-GRE: p = 0.015; HR 3D-GRE: p = 0.006). At 3 Tesla the mean SNR and CNR were significantly higher (p < 0.05). A {kappa} of 0.67 indicated good interobserver agreement. (orig.)

  14. Intraindividual comparison of image quality in MR urography at 1.5 and 3 Tesla in an animal model

    International Nuclear Information System (INIS)

    Regier, M.; Adam, G.; Kemper, J.; Nolte-Ernsting, C.

    2008-01-01

    Purpose: experimental evaluation of image quality of the upper urinary tract in MR urography (MRU) at 1.5 and 3 Tesla in a porcine model. Materials and methods: in this study four healthy domestic pigs, weighing between 71 and 80 kg (mean 73.6 kg), were examined with a standard T 1w 3D-GRE and a high-resolution (HR) T 1w 3D-GRE sequence at 1.5 and 3 Tesla. Additionally, at 3 Tesla both sequences were performed with parallel imaging (SENSE factor 2). The MR urographic scans were performed after intravenous injection of gadolinium-DTPA (0.1 mmol/kg body weight (bw)) and low-dose furosemide (0.1 mg/kg bw). Image evaluation was performed by two independent radiologists blinded to sequence parameters and field strength. Image analysis included grading of image quality of the segmented collecting system based on a five-point grading scale regarding anatomical depiction and artifacts observed (1: the majority of the segment (> 50%) was not depicted or was obscured by major artifacts; 5: the segment was visualized without artifacts and had sharply defined borders). Signal-to-noise (SNR) and contrast-to-noise (CNR) ratios were determined. Statistical analysis included κ-statistics, Wilcoxon and paired student t-test. Results: the mean scores for MR urographies at 1.5 Tesla were 2.83 for the 3D-GRE and 3.48 for the HR 3D-GRE sequence. Significantly higher values were determined using the corresponding sequences at 3 Tesla, averaging 3.19 for the 3D-GRE (p 0.047) and 3.92 for the HR 3D-GRE (p = 0.023) sequence. Delineation of the pelvicaliceal system was rated significantly higher at 3 Tesla compared to 1.5 Tesla (3D-GRE: p = 0.015; HR 3D-GRE: p = 0.006). At 3 Tesla the mean SNR and CNR were significantly higher (p < 0.05). A κ of 0.67 indicated good interobserver agreement. (orig.)

  15. A 4 Tesla/1 meter superferric MRI magnet

    International Nuclear Information System (INIS)

    Schmidt, W.M.; Huson, F.R.; Mackay, W.W.; Rocha, R.M.

    1991-01-01

    Superferric technology was first applied to Magnetic Resonance Imaging (MRI) magnets by the Texas Accelerator Center (TAC) in 1986 with the design and construction of a 4 Tesla/30 cm magnet. In an evolutionary step, this technology is now being applied to the development of a whole body 4 Tesla/1 meter superconducting magnet. The design of such a magnetis presented in this paper

  16. Beam orbit control in TESLA superconducting cavities from dipole mode measurements

    International Nuclear Information System (INIS)

    Paparella, R.

    2006-09-01

    The knowledge of the electromagnetic interaction between a beam and the surrounding vacuum chamber is necessary in order to optimize the accelerator performance in terms of stored current. Many instability phenomena may occur in the machine because of the fields produced by the beam and acting back on itself. Basically, these fields, wake-fields, produce an extra voltage, affecting the longitudinal dynamics, and a transverse kick which deflects the beam. In this thesis we present the results of theoretical and experimental investigations to demonstrate the possibility of using the dipolar wake fields of the superconducting accelerating to measure the beam transverse position. After an introduction to the ILC project and to the TESLA technology, of superconducting RF cavities, we will approach the problem from an analytical point of view in chapter 2. The expression of the wake fields in a cylindrical cavity will be investigated and the electromagnetic field modes derived from Maxwell equations in an original way. Graphical solutions of a Matlab program simulating the fields due to a particle passing through a pill-box cavity along a generic path will be shown. The interaction of the beam with higher order modes (HOM) in the TESLA cavities has been studied in the past at the TESLA Test Facility (TTF) in order to determine whether the modes with the highest loss factor are sufficiently damped. Starting from the results obtained before 2003, HOM signals has been better observed and examined in order to use dipole modes to find the electric center of each cavity in the first TTF accelerating module. The results presented in chapter 3 will show that by monitoring the HOM signal amplitude for two polarizations of a dipole mode, one can measure electrical center of the modes with a resolution of 50 μm. Moreover, a misalignment of the first TTF module with respect to the gun axis has been predicted using cavity dipole modes. Alternatives to this method are described in

  17. Effects of magnetic field on mental health staff employed in gas power plant, Shiraz, 2008

    Directory of Open Access Journals (Sweden)

    S. Gharepoor

    2010-10-01

    Full Text Available Background and aimsIn the industrial world, almost everyone is unavoidably exposed to ambient magnetic field (ELF generated by various technical and household appliances. According to the studies carried out in a power station in Shiraz, psychological disorders causedby jobs are among the most important problems of the workers.MethodsThis study is performed to determine the presence or absence of psychological disorders. The General Health Questionnaire (GHQ is used in this study to recognize psychosomatic disorders.ResultsMeasurements indicate that range of magnetic field varies from 0.087 micro Tesla(in the phone homes to 30micro Tesla( in power stations. The results of this study has shown that a significant number of staff which were exposed to magnetic fields and noise 78.2% were suspected to have a kind of mental disorders.ConclusionThe results obtained from this study which shows the prevalence of mental disorders among the suspected case is higher than the results of Noorbala and colleagues study in 2006. Therefore, there are necessities to do more research in order to find the relationship between electric and magnetic fields and psychological disorders.

  18. 76 FR 60124 - Tesla Motors, Inc.; Grant of Petition for Temporary Exemption From the Electronic Stability...

    Science.gov (United States)

    2011-09-28

    ...-0110] Tesla Motors, Inc.; Grant of Petition for Temporary Exemption From the Electronic Stability... notice grants the petition of Tesla Motors, Inc. (Tesla) for the temporary exemption of its Roadster... procedures in 49 CFR Part 555, Tesla Motors, Inc. (Tesla) submitted a petition dated June 7, 2011 asking the...

  19. Drift chamber performance in the field of a superconducting magnet: measurement of the drift angle

    International Nuclear Information System (INIS)

    Sanders, G.H.; Sherman, S.; McDonald, K.T.; Smith, A.J.S.; Thaler, J.J.

    1977-01-01

    Results are presented of the first measurements in a study of drift chamber performance in magnetic fields up to 6 tesla. The angle of the electron drift was measured as a function of electric and magnetic field intensity. It appears that even at the high fields of superconducting magnets (3 to 6 tesla) the drift angle induced by the Lorentz force can be corrected for with tilted electric drift fields and/or the use of Xenon gas. At 3 tesla a drift field tilted at 45 0 with a magnitude of 3.5 kV/cm should restore normal operating conditions. At 4 tesla, a 45 0 tilt field would have a magnitude 5 kV/cm

  20. TeSLA e-assessment workshop

    NARCIS (Netherlands)

    Janssen, José

    2016-01-01

    Presentatie ten behoeve van de e-assessment workshop voor docenten van de Open Universiteit Nederland betrokken in de eerste TeSLA pilot. Topics: toetsfraude, toetsdesign, technologie voor authenticatie en verificatie van auteurschap.

  1. Nikola Tesla: the Moon's rotation.

    Science.gov (United States)

    Tomić, A.; Jovanović, B. S.

    1993-09-01

    The review of three articles by N. Tesla, published in the year 1919 in the journal "Electrical experimenter" is given, with special reference to the astronomical contents and to circumstances in which they appeared.

  2. Cortical microinfarcts detected in vivo on 3 tesla MRI : Clinical and radiological correlates

    NARCIS (Netherlands)

    Van Dalen, Jan Willem; Scuric, Eva E M; Van Veluw, Susanne J.; Caan, Matthan W A; Nederveen, Aart J.; Biessels, Geert Jan; Van Gool, Willem A.; Richard, Edo

    2015-01-01

    Background and Purpose-Cortical microinfarcts (CMIs) are a common postmortem finding associated with vascular risk factors, cognitive decline, and dementia. Recently, CMIs identified in vivo on 7 Tesla MRI also proved retraceable on 3 Tesla MRI. Methods-We evaluated CMIs on 3 Tesla MRI in a

  3. Cortical microinfarcts detected in vivo on 3 Tesla MRI: clinical and radiological correlates

    NARCIS (Netherlands)

    Dalen, J.W. van; Scuric, E.E.; Veluw, S.J. van; Caan, M.W.; Nederveen, A.J.; Biessels, G.J.; Gool, W.A. van; Richard, E.

    2015-01-01

    BACKGROUND AND PURPOSE: Cortical microinfarcts (CMIs) are a common postmortem finding associated with vascular risk factors, cognitive decline, and dementia. Recently, CMIs identified in vivo on 7 Tesla MRI also proved retraceable on 3 Tesla MRI. METHODS: We evaluated CMIs on 3 Tesla MRI in a

  4. Undulator systems for the TESLA X-FEL

    International Nuclear Information System (INIS)

    Pflueger, J.; Tischer, M.

    2002-01-01

    A large X-ray FEL lab is under consideration within the TESLA project and is supposed to be operated in parallel with the TESLA linear collider. There will be five SASE FELs and five conventional spontaneous undulators. A conceptual design study has been made for the undulator systems for these X-FELs. It includes segmentation into 6.1 m long undulator 'cells'. Each consists of a 5 m long undulator 'segment', a separate quadrupole, one horizontal and one vertical corrector, and a phase shifter. These items are presented and discussed

  5. Radiation protection systems on the TESLA Accelerator Installation

    International Nuclear Information System (INIS)

    Pavlovic, R.

    1996-01-01

    In the Institute of Nuclear sciences VINCA, the Accelerator Installation TESLA which is an medium energy ion accelerator facility consisting of an isochronous cyclotron VINCY, a heavy ion source, a D/H ion source, three low energy and five high energy experimental channels is now under construction. Some problems in defining radiation protection and safety programme, particularly problems in construction appropriate shielding barriers at the Accelerator Installation TESLA are discussed in this paper. (author

  6. Superconducting magnet package for the TESLA test facility

    International Nuclear Information System (INIS)

    Koski, A.; Bandelmann, R.; Wolff, S.

    1996-01-01

    The magnetic lattice of the TeV electron superconducting linear accelerator (TESLA) will consist of superconducting quadrupoles for beam focusing and superconducting correction dipoles for beam steering, incorporated in the cryostats containing the superconducting cavities. This report describes the design of these magnets, presenting details of the magnetic as well as the mechanical design. The measured characteristics of the TESLA Test Facility (TTF) quadrupoles and dipoles are compared to the results obtained from numerical computations

  7. Ventricular Assist Device implant (AB 5000 prototype cannula: In vitro assessment of MRI issues at 3-Tesla

    Directory of Open Access Journals (Sweden)

    Valencerina Samuel

    2008-05-01

    Full Text Available Abstract Purpose To evaluate MRI issues at 3-Tesla for a ventricular assist device (VAD. Methods The AB5000 Ventricle with a prototype Nitinol wire-reinforced In-Flow Cannula and Out-Flow Cannula attached (Abiomed, Inc., Danvers, MA was evaluated for magnetic field interactions, heating, and artifacts at 3-Tesla. MRI-related heating was assessed with the device in a gelled-saline-filled, head/torso phantom using a transmit/received RF body coil while performing MRI at a whole body averaged SAR of 3-W/kg for 15-min. Artifacts were assessed for the main metallic component of this VAD (atrial cannula using T1-weighted, spin echo and gradient echo pulse sequences. Results The AB5000 Ventricle with the prototype In-Flow Cannula and Out-Flow Cannula attached showed relatively minor magnetic field interactions that will not cause movement in situ. Heating was not excessive (highest temperature change, +0.8°C. Artifacts may create issues for diagnostic imaging if the area of interest is in the same area or close to the implanted metallic component of this VAD (i.e., the venous cannula. Conclusion The results of this investigation demonstrated that it would be acceptable for a patient with this VAD (AB5000 Ventricle with a prototype Nitinol wire-reinforced In-Flow Cannula and Out-Flow Cannula attached to undergo MRI at 3-Tesla or less. Notably, it is likely that the operation console for this device requires positioning a suitable distance (beyond the 100 Gauss line or in the MR control room from the 3-Tesla MR system to ensure proper function of the VAD.

  8. Cryogenic Current Comparator for Absolute Measurement of the Dark Current of the Superconducting Cavities for Tesla

    CERN Document Server

    Knaack, K; Wittenburg, K

    2003-01-01

    A newly high performance SQUID based measurement system for detecting dark currents, generated by superconducting cavities for TESLA is proposed. It makes use of the Cryogenic Current Comparator principle and senses dark currents in the nA range with a small signal bandwidth of 70 kHz. To reach the maximum possible energy in the TESLA project is a strong motivation to push the gradients of the superconducting cavities closer to the physical limit of 50 MV/m. The field emission of electrons (the so called dark current) of the superconducting cavities at strong fields may limit the maximum gradient. The absolute measurement of the dark current in correlation with the gradient will give a proper value to compare and classify the cavities. This contribution describes a Cryogenic Current Comparator (CCC) as an excellent and useful tool for this purpose. The most important component of the CCC is a high performance DC SQUID system which is able to measure extremely low magnetic fields, e.g. caused by the extracted ...

  9. 77 FR 22383 - Petition for Exemption From the Federal Motor Vehicle Motor Theft Prevention Standard; TESLA

    Science.gov (United States)

    2012-04-13

    ... From the Federal Motor Vehicle Motor Theft Prevention Standard; TESLA AGENCY: National Highway Traffic... exemption. SUMMARY: This document grants in full the petition of Tesla Motors Inc's. (Tesla) for an... 49 CFR Part 541, Federal Motor Vehicle Theft Prevention Standard. Tesla requested confidential...

  10. Metal artifact suppression at the hip: diagnostic performance at 3.0 T versus 1.5 Tesla

    Energy Technology Data Exchange (ETDEWEB)

    Nardo, Lorenzo; Han, Misung; Kretschmar, Martin; Krug, Roland; Link, Thomas M. [University of California San Francisco, Musculoskeletal and Quantitative Imaging Research, Department of Radiology and Biomedical Imaging, San Francisco, CA (United States); Guindani, Michele [The University of Texas MD Anderson Cancer Center, Department of Biostatistics - Unit 1411, Houston, TX (United States); Koch, Kevin [Medical College of Wisconsin, Department of Biophysics, Milwaukee, WI (United States); Medical College of Wisconsin, Department of Radiology, Milwaukee, WI (United States); Vail, Thomas [University of California San Francisco, Department of Orthopedic Surgery, San Francisco, CA (United States)

    2015-11-15

    This work aimed to compare the diagnostic performance of a metal artifact suppression sequence (MAVRIC-SL) for imaging of hip arthroplasties (HA) at 1.5 and 3 Tesla (T) field strength. Eighteen patients (10 females; aged 27-74) with HA were examined at 3.0 and 1.5 T within 3 weeks. The sequence protocol included 3D-MAVRIC-SL PD (coronal), 3D-MAVRIC-SL STIR (axial), FSE T1, FSE PD and STIR sequences. Anatomical structures and pathological findings were assessed independently by two radiologists. Artifact extent and technical quality (image quality, fat saturation and geometric distortion) were also evaluated. Findings at 1.5 and 3.0 T were compared using a Wilcoxon signed rank test. While image quality was better at 1.5 T, visualization of anatomic structures and clinical abnormalities was not significantly different using the two field strengths (p > 0.05). Fat suppression and amount of artifacts were significantly better at 1.5 T (p < 0.01). Inter- and intra-reader agreement for different anatomic details, image quality and visualization of abnormalities ranged from k = 0.62 to k = 1.00. MAVRIC-SL at 1.5 T had a comparable diagnostic performance when compared MAVRIC-SL at 3.0 T; however, the higher field strength was associated with larger artifacts, limited image quality and worse fat saturation. (orig.)

  11. Metal artifact suppression at the hip: diagnostic performance at 3.0 T versus 1.5 Tesla

    International Nuclear Information System (INIS)

    Nardo, Lorenzo; Han, Misung; Kretschmar, Martin; Krug, Roland; Link, Thomas M.; Guindani, Michele; Koch, Kevin; Vail, Thomas

    2015-01-01

    This work aimed to compare the diagnostic performance of a metal artifact suppression sequence (MAVRIC-SL) for imaging of hip arthroplasties (HA) at 1.5 and 3 Tesla (T) field strength. Eighteen patients (10 females; aged 27-74) with HA were examined at 3.0 and 1.5 T within 3 weeks. The sequence protocol included 3D-MAVRIC-SL PD (coronal), 3D-MAVRIC-SL STIR (axial), FSE T1, FSE PD and STIR sequences. Anatomical structures and pathological findings were assessed independently by two radiologists. Artifact extent and technical quality (image quality, fat saturation and geometric distortion) were also evaluated. Findings at 1.5 and 3.0 T were compared using a Wilcoxon signed rank test. While image quality was better at 1.5 T, visualization of anatomic structures and clinical abnormalities was not significantly different using the two field strengths (p > 0.05). Fat suppression and amount of artifacts were significantly better at 1.5 T (p < 0.01). Inter- and intra-reader agreement for different anatomic details, image quality and visualization of abnormalities ranged from k = 0.62 to k = 1.00. MAVRIC-SL at 1.5 T had a comparable diagnostic performance when compared MAVRIC-SL at 3.0 T; however, the higher field strength was associated with larger artifacts, limited image quality and worse fat saturation. (orig.)

  12. Hydroforming of superconducting TESLA cavities

    International Nuclear Information System (INIS)

    Singer, W.; Kaiser, H.; Singer, X.

    2003-01-01

    Seamless fabrication of single-cell and multi-cell TESLA shape cavities by hydroforming has been developed at DESY. The forming takes place by expanding the seamless tube with internal water pressure while simultaneously swaging it axially. Tube radius and axial displacement are being computer controlled in accordance with results of FEM simulations and the experimentally obtained strain-stress curve of tube material. Several Nb single cell cavities have been produced. A first bulk Nb double cell cavity has been fabricated. The Nb seamless tubes have been produced by spinning and deep drawing. Surface treatment such as buffered chemical polishing, (BCP), electropolishing (EP), high pressure ultra pure water rinsing (HPR), annealing at 800degC and baking at ca. 150degC have been applied. The best single cell bulk Nb cavity has reached an accelerating gradient of Eacc > 42 MV/m after ca. 250 μm BCP and 100 μm EP. Several bimetallic NbCu single cell cavities of TESLA shape have been fabricated. The seamless tubes have been produced by explosive bonding and subsequent flow forming. The thicknesses of Nb and Cu layers in the tube wall are about 1 mm and 3 mm respectively. The RF performance of NbCu clad cavities is similar to that of bulk Nb cavities. The highest accelerating gradient achieved was 40 MV/m after ca. 180 μm BCP, annealing at 800degC and baking at 140degC for 30 hours. The degradation of the quality factor Qo after repeated quenching is moderate, after ca. 150 quenches it reaches the saturation point of Qo=1.4x10 10 at low field. This indicates that on the basis of RF performance and material costs the combination of hydroforming with tube cladding is a very promising option. (author)

  13. High field septum magnet using a superconducting shield for the Future Circular Collider

    Directory of Open Access Journals (Sweden)

    Dániel Barna

    2017-04-01

    Full Text Available A zero-field cooled superconducting shield is proposed to realize a high-field (3–4 T septum magnet for the Future Circular Collider hadron-hadron (FCC-hh ring. Three planned prototypes using different materials and technical solutions are presented, which will be used to evaluate the feasibility of this idea as a part of the FCC study. The numerical simulation methods are described to calculate the field patterns around such a shield. A specific excitation current configuration is presented that maintains a fairly homogeneous field outside of a rectangular shield in a wide range of field levels from 0 to 3 Tesla. It is shown that a massless septum configuration (with an opening in the shield is also possible and gives satisfactory field quality with realistic superconducting material properties.

  14. High field septum magnet using a superconducting shield for the Future Circular Collider

    CERN Document Server

    AUTHOR|(CDS)2069375

    2017-01-01

    A zero-field cooled superconducting shield is proposed to realize a high-field (3–4 T) septum magnet for the Future Circular Collider hadron-hadron (FCC-hh) ring. Three planned prototypes using different materials and technical solutions are presented, which will be used to evaluate the feasibility of this idea as a part of the FCC study. The numerical simulation methods are described to calculate the field patterns around such a shield. A specific excitation current configuration is presented that maintains a fairly homogeneous field outside of a rectangular shield in a wide range of field levels from 0 to 3 Tesla. It is shown that a massless septum configuration (with an opening in the shield) is also possible and gives satisfactory field quality with realistic superconducting material properties.

  15. Women’s Participation in Scientific and Technical Field in Malaysia

    Directory of Open Access Journals (Sweden)

    Nuraihan Mat Daud

    1999-12-01

    Full Text Available The scientific and technical fields are generally dominated by men. Women tend to shy away from using technical devices and from trying to understand the principles behind their operation. One of the major reasons for their seemingly lack of interest is the lack of encouragement from their family and society. This paper discusses the steps taken by a country, namely, Malaysia, to encourage its female population to venture into this area. Policies were created by the government for this purpose. Great emphasis is given on education, which is one of the important factors influencing one's choice of vocation. In its process of restructuring the society, the government has effectively increased the involvement of women particularly the Muslims in the professional and technical fields as the vast opportunities are provided for them to pursue their studies in this area. There is a marked increase in the number of female student intake in technical and vocational institutions. There is also an increase in the number of females in related fields such as accountancy, engineering, architecture and medicine. The ratio of male to female involvement has however not changed much when the figures are analysed.

  16. The Superconducting TESLA Cavities

    CERN Document Server

    Aune, B.; Bloess, D.; Bonin, B.; Bosotti, A.; Champion, M.; Crawford, C.; Deppe, G.; Dwersteg, B.; Edwards, D.A.; Edwards, H.T.; Ferrario, M.; Fouaidy, M.; Gall, P-D.; Gamp, A.; Gössel, A.; Graber, J.; Hubert, D.; Hüning, M.; Juillard, M.; Junquera, T.; Kaiser, H.; Kreps, G.; Kuchnir, M.; Lange, R.; Leenen, M.; Liepe, M.; Lilje, L.; Matheisen, A.; Möller, W-D.; Mosnier, A.; Padamsee, H.; Pagani, C.; Pekeler, M.; Peters, H-B.; Peters, O.; Proch, D.; Rehlich, K.; Reschke, D.; Safa, H.; Schilcher, T.; Schmüser, P.; Sekutowicz, J.; Simrock, S.; Singer, W.; Tigner, M.; Trines, D.; Twarowski, K.; Weichert, G.; Weisend, J.; Wojtkiewicz, J.; Wolff, S.; Zapfe, K.

    2000-01-01

    The conceptional design of the proposed linear electron-positron colliderTESLA is based on 9-cell 1.3 GHz superconducting niobium cavities with anaccelerating gradient of Eacc >= 25 MV/m at a quality factor Q0 > 5E+9. Thedesign goal for the cavities of the TESLA Test Facility (TTF) linac was set tothe more moderate value of Eacc >= 15 MV/m. In a first series of 27industrially produced TTF cavities the average gradient at Q0 = 5E+9 wasmeasured to be 20.1 +- 6.2 MV/m, excluding a few cavities suffering fromserious fabrication or material defects. In the second production of 24 TTFcavities additional quality control measures were introduced, in particular aneddy-current scan to eliminate niobium sheets with foreign material inclusionsand stringent prescriptions for carrying out the electron-beam welds. Theaverage gradient of these cavities at Q0 = 5E+9 amounts to 25.0 +- 3.2 MV/mwith the exception of one cavity suffering from a weld defect. Hence only amoderate improvement in production and preparation technique...

  17. Optic Nerve Assessment Using 7-Tesla Magnetic Resonance Imaging.

    Science.gov (United States)

    Singh, Arun D; Platt, Sean M; Lystad, Lisa; Lowe, Mark; Oh, Sehong; Jones, Stephen E; Alzahrani, Yahya; Plesec, Thomas

    2016-04-01

    The purpose of this study was to correlate high-resolution magnetic resonance imaging (MRI) and histologic findings in a case of juxtapapillary choroidal melanoma with clinical evidence of optic nerve invasion. With institutional review board approval, an enucleated globe with choroidal melanoma and optic nerve invasion was imaged using a 7-tesla MRI followed by histopathologic evaluation. Optical coherence tomography, B-scan ultrasonography, and 1.5-tesla MRI of the orbit (1-mm sections) could not detect optic disc invasion. Ex vivo, 7-tesla MRI detected optic nerve invasion, which correlated with histopathologic features. Our case demonstrates the potential to document the existence of optic nerve invasion in the presence of an intraocular tumor, a feature that has a major bearing on decision making, particularly for consideration of enucleation.

  18. [Examination of upper abdominal region in high spatial resolution diffusion-weighted imaging using 3-Tesla MRI].

    Science.gov (United States)

    Terada, Masaki; Matsushita, Hiroki; Oosugi, Masanori; Inoue, Kazuyasu; Yaegashi, Taku; Anma, Takeshi

    2009-03-20

    The advantage of the higher signal-to-noise ratio (SNR) of 3-Tesla magnetic resonance imaging (3-Tesla) has the possibility of contributing to the improvement of high spatial resolution without causing image deterioration. In this study, we compared SNR and the apparent diffusion coefficient (ADC) value with 3-Tesla as the condition in the diffusion-weighted image (DWI) parameter of the 1.5-Tesla magnetic resonance imaging (1.5-Tesla) and we examined the high spatial resolution images in the imaging method [respiratory-triggering (RT) method and breath free (BF) method] and artifact (motion and zebra) in the upper abdominal region of DWI at 3-Tesla. We have optimized scan parameters based on phantom and in vivo study. As a result, 3-Tesla was able to obtain about 1.5 times SNR in comparison with the 1.5-Tesla, ADC value had few differences. Moreover, the RT method was effective in correcting the influence of respiratory movement in comparison with the BF method, and image improvement by the effective acquisition of SNR and reduction of the artifact were provided. Thus, DWI of upper abdominal region was a useful sequence for the high spatial resolution in 3-Tesla.

  19. Nikola Tesla Educational Opportunity School.

    Science.gov (United States)

    Design Cost Data, 2001

    2001-01-01

    Describes the architectural design, costs, general description, and square footage data for the Nikola Tesla Educational Opportunity School in Colorado Springs, Colorado. A floor plan and photos are included along with a list of manufacturers and suppliers used for the project. (GR)

  20. MRI of the carotid artery at 7 Tesla: Quantitative comparison with 3 Tesla

    NARCIS (Netherlands)

    Koning, Wouter; De Rotte, Alexandra A J; Bluemink, Johanna J.; Van Der Velden, Tijl A.; Luijten, Peter R.; Klomp, DWJ; Zwanenburg, Jaco J M

    2015-01-01

    Purpose: To evaluate the 7 Tesla (T) MRI of the carotid arteries, as quantitatively compared with 3T. Materials and Methods: The 7T MRI of the carotid arteries was performed in six healthy subjects and in two patients with carotid stenosis. The healthy group was scanned at 3T and at 7T, using

  1. 76 FR 47639 - Tesla Motors, Inc.; Receipt of Petition for Temporary Exemption From the Electronic Stability...

    Science.gov (United States)

    2011-08-05

    ...-0110] Tesla Motors, Inc.; Receipt of Petition for Temporary Exemption From the Electronic Stability... accordance with the procedures in 49 CFR part 555, Tesla Motors, Inc., has petitioned the agency for a... part 555, Tesla Motors, Inc. (Tesla) submitted a petition dated June 7, 2001 asking the agency for a...

  2. Enhancing Thailand’s international competitiveness through women’s enrolment in technical fields in tertiary education

    OpenAIRE

    Rapson, Keira Jean Margaret

    2010-01-01

    Women’s low enrolment in technical fields in tertiary education is a worldwide phenomenon that is an area of concern for women’s equality. While this concern is substantial, a much greater concern for women’s low enrolment in technical fields is how their absence can affect a developing country. This paper will explore the role of women in technical fields in development. This paper hypothesizes that women represent a distinctive body of labour in technical fields as a result of their unique ...

  3. Using 3 Tesla magnetic resonance imaging in the pre-operative evaluation of tongue carcinoma.

    Science.gov (United States)

    Moreno, K F; Cornelius, R S; Lucas, F V; Meinzen-Derr, J; Patil, Y J

    2017-09-01

    This study aimed to evaluate the role of 3 Tesla magnetic resonance imaging in predicting tongue tumour thickness via direct and reconstructed measures, and their correlations with corresponding histological measures, nodal metastasis and extracapsular spread. A prospective study was conducted of 25 patients with histologically proven squamous cell carcinoma of the tongue and pre-operative 3 Tesla magnetic resonance imaging from 2009 to 2012. Correlations between 3 Tesla magnetic resonance imaging and histological measures of tongue tumour thickness were assessed using the Pearson correlation coefficient: r values were 0.84 (p Tesla magnetic resonance imaging had 83 per cent sensitivity, 82 per cent specificity, 82 per cent accuracy and a 90 per cent negative predictive value for detecting cervical lymph node metastasis. In this cohort, 3 Tesla magnetic resonance imaging measures of tumour thickness correlated highly with the corresponding histological measures. Further, 3 Tesla magnetic resonance imaging was an effective method of detecting malignant adenopathy with extracapsular spread.

  4. Conduction-coupled Tesla transformer.

    Science.gov (United States)

    Reed, J L

    2015-03-01

    A proof-of-principle Tesla transformer circuit is introduced. The new transformer exhibits the high voltage-high power output signal of shock-excited transformers. The circuit, with specification of proper circuit element values, is capable of obtaining extreme oscillatory voltages. The primary and secondary portions of the circuit communicate solely by conduction. The destructive arcing between the primary and secondary inductors in electromagnetically coupled transformers is ubiquitous. Flashover is eliminated in the new transformer as the high-voltage inductors do not interpenetrate and so do not possess an annular volume of electric field. The inductors are remote from one another. The high voltage secondary inductor is isolated in space, except for a base feed conductor, and obtains earth by its self-capacitance to the surroundings. Governing equations, for the ideal case of no damping, are developed from first principles. Experimental, theoretical, and circuit simulator data are presented for the new transformer. Commercial high-temperature superconductors are discussed as a means to eliminate the counter-intuitive damping due to small primary inductances in both the electromagnetic-coupled and new conduction-coupled transformers.

  5. Detailed survey of 60-Hz magnetic fields in schools

    International Nuclear Information System (INIS)

    Peralta, S.B.; Mader, D.L.; Scheer, R.R.

    1991-01-01

    Data concerning magnetic field exposure levels in schools is sparse in comparison with data for houses. Surveys were made of power frequency magnetic fields in two schools in the Toronto area of Ontario. One school was a small, older school with a relatively simple electrical network, while the other was a newer, larger facility with more a complex system. Measured field levels clustered around the 0.06-0.125 microTesla range, a factor of two less than the fields commonly encountered in homes. Classrooms exhibited low-level fields, typically of the order of 0.05 microTesla. While a transmission line near one school raised ambient levels slightly, fields were mainly due to local sources such as building wiring and distribution panels. In one school, the major field source is a site transformer. However, the highest fields outside the transformer room, 0.3 microTesla, are found right next to the room, and decay rapidly with distance from the transformer. 7 refs., 24 figs

  6. The excitation system of 727.5 MVA synchronous generator of the unit B1 in TPP 'Nikola Tesla B'

    Directory of Open Access Journals (Sweden)

    Ćirić Zoran

    2013-01-01

    Full Text Available This paper presents a technical solution for the replacement of the excitation system of the unit B1 in TPP 'Nikola Tesla B' as a part of the maintenance service in 2012. Since the generators of TPP 'Nikola Tesla B' have the greatest power in the power system of Serbia, it was necessary to achieve high reliability of the excitation system so that the process of producing electricity is not endangered Considering this, the implemented excitation system uses modern technology with redundancy both in the power and control blocks, which resulted in an increase in the hot reserve by 100%. In addition, it was necessary to adjust the excitation system to increased generator power and performance from 618MW to 667.5MW. In this paper, the main parameters of the excitation system are given: the power, the excitation system control, the thyristor ignition system, the event recorder system, the digital relay protection, as well as the measuring and signaling functions.

  7. Spherical near-field scanning at the Technical University of Denmark

    DEFF Research Database (Denmark)

    Hansen, J. E.; Jensen, F.

    1988-01-01

    The early work (1969-79) on spherical near-field antenna measurements at the Technical University of Denmark (TUD) is outlined. A spherical near-field transmission formula is described and the first probe-corrected spherical near-field measurements are discussed. The TUD-ESA (European Space Agency...

  8. MRI safety of a programmable shunt assistant at 3 and 7 Tesla.

    Science.gov (United States)

    Mirzayan, M Javad; Klinge, Petra M; Samii, Madjid; Goetz, Friedrich; Krauss, Joachim K

    2012-06-01

    Several new shunt technologies have been developed to optimize hydrocephalus treatment within the past few years. Overdrainage, however, still remains an unresolved problem. One new technology which may reduce the frequency of this complication is the use of a programmable shunt assistant (proSA). Inactive in a horizontal position, it impedes CSF flow in a vertical position according to a prescribed pressure level ranging from 0 to 40 cm H(2)O. We exposed the proSA valve in an ex vivo protocol to MR systems operating at 3 and 7 Tesla to investigate its MRI safety. Following 3 Tesla exposure, no changes in valve settings were noted. Adjustment to any pressure level was possible thereafter. The mean deflection angle was 23 ± 3°. After exposure to 7 Tesla, however, there were unintended pressure changes, and the mechanism for further adjustment of the valves even disintegrated. According to the results of this study, proSA is safe with heteropolar vertical magnet alignment at 3 Tesla. Following 7 Tesla exposure, the valves lost their functional capability.

  9. Analysis and tests of TF magnet insulation samples for the JET upgrade to 4 tesla

    CERN Document Server

    Miele, P; Bettinali, L; Kaye, A; Last, J; Papastergiou, S; Riccardo, V; Visca, E

    2000-01-01

    The JET Toroidal Field (TF) coils were originally designed for operation at 3.4 tesla. In order to upgrade the field to 4 tesla and thus improve the performance of the JET machine, new mechanical tests and analysis were carried out on the insulation of TF coil samples. They are aimed at investigating the mechanical properties and the status of the insulation in order to set allowable stresses and force limits. In particular since the shear stress in the insulation is strongly affected by the shear modulus of elasticity G, it is important to measure this parameter. A method for the measurement of G in glass-resin fibres, the V-notched beam method (Iosipescu method) , was applied. The particular shape of the rectangular Iosipescu V- notched sample and the particular modality of force application produce pure shear stress for a reliable measurement of the G value and of the shear strength of the insulation. The effect of temperature on these mechanical properties was also investigated. Results show higher averag...

  10. Calculation of secondary capacitance of compact Tesla pulse transformer

    International Nuclear Information System (INIS)

    Yu Binxiong; Liu Jinliang

    2013-01-01

    An analytic expression of the secondary capacitance of a compact Tesla pulse transformer is derived. Calculated result by the expression shows that two parts contribute to the secondary capacitance, namely the capacitance between inner and outer magnetic cores and the attached capacitance caused by the secondary winding. The attached capacitance equals to the capacitance of a coaxial line which is as long as the secondary coil, and whose outer and inner diameters are as large as the inner diameter of the outer magnetic and the outer diameter of the inner magnetic core respectively. A circuital model for analyzing compact Tesla transformer is built, and numeric calculation shows that the expression of the secondary capacitance is correct. Besides, a small compact Tesla transformer is developed, and related test is carried out. Test result confirms the calculated results by the expression derived. (authors)

  11. In vivo High Angular Resolution Diffusion-Weighted Imaging of Mouse Brain at 16.4 Tesla

    OpenAIRE

    Alomair, Othman I.; Brereton, Ian M.; Smith, Maree T.; Galloway, Graham J.; Kurniawan, Nyoman D.

    2015-01-01

    Magnetic Resonance Imaging (MRI) of the rodent brain at ultra-high magnetic fields (> 9.4 Tesla) offers a higher signal-to-noise ratio that can be exploited to reduce image acquisition time or provide higher spatial resolution. However, significant challenges are presented due to a combination of longer T 1 and shorter T 2/T2* relaxation times and increased sensitivity to magnetic susceptibility resulting in severe local-field inhomogeneity artefacts from air pockets and bone/brain interfaces...

  12. Technical design issues for a field-portable supercritical fluid extractor

    Energy Technology Data Exchange (ETDEWEB)

    Wright, B.W.; Zemanian, T.S.; Robins, W.H.; Wright, C.W.

    1995-01-01

    Supercritical fluid extraction is gaining acceptance as an alternative sample preparation method for trace organic analysis. The development of SFE instrumentation optimized for field use requires taking several technical design issues including size and weight requirements, user-friendly operation, and technical performance capabilities into consideration. Parameters associated with a prototype SFE instrument under development for potential use in conducting on-site inspections of the Chemical Weapons Convention and its preliminary technical and operational performance are described.

  13. 77 FR 2269 - Foreign-Trade Zone 18-San Jose, CA, Application for Subzone, Tesla Motors, Inc. (Electric...

    Science.gov (United States)

    2012-01-17

    ..., CA, Application for Subzone, Tesla Motors, Inc. (Electric Passenger Vehicles), Palo Alto and Fremont... passenger- vehicle manufacturing facilities of Tesla Motors, Inc. (Tesla), located in Palo Alto and Fremont... January 10, 2012. The Tesla facilities (currently employing over 1,000 workers) consist of two sites: Site...

  14. Cervical external immobilization devices: evaluation of magnetic resonance imaging issues at 3.0 Tesla.

    Science.gov (United States)

    Diaz, Francis L; Tweardy, Lisa; Shellock, Frank G

    2010-02-15

    Laboratory investigation, ex vivo. Currently, no studies have addressed the magnetic resonance imaging (MRI) issues for cervical external immobilization devices at 3-Tesla. Under certain conditions significant heating may occur, resulting in patient burns. Furthermore, artifacts can be substantial and prevent the diagnostic use of MRI. Therefore, the objective of this investigation was to evaluate MRI issues for 4 different cervical external immobilization devices at 3-Tesla. Excessive heating and substantial artifacts are 2 potential complications associated with performing MRI at 3-Tesla in patients with cervical external immobilization devices. Using ex vivo testing techniques, MRI-related heating and artifacts were evaluated for 4 different cervical devices during MRI at 3-Tesla. Four cervical external immobilization devices (Generation 80, Resolve Ring and Superstructure, Resolve Ring and Jerome Vest/Jerome Superstructure, and the V1 Halo System; Ossur Americas, Aliso Viejo, CA) underwent MRI testing at 3-Tesla. All devices were made from nonmetallic or nonmagnetic materials. Heating was determined using a gelled-saline-filled skull phantom with fluoroptic thermometry probes attached to the skull pins. MRI was performed at 3-Tesla, using a high level of RF energy. Artifacts were assessed at 3-Tesla, using standard cervical imaging techniques. The Generation 80 and V1 Halo devices exhibited substantial temperature rises (11.6 degrees C and 8.5 degrees C, respectively), with "sparking" evident for the Generation 80 during the MRI procedure. Artifacts were problematic for these devices, as well. By comparison, the 2 Resolve Ring-based cervical external immobilization devices showed little or no heating (Tesla.

  15. The Legacy of Nikola Tesla

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 12; Issue 4. The Legacy of Nikola Tesla - AC Power System and its Growth in India. D P Sen Gupta. General Article Volume 12 Issue 4 April 2007 pp 69-79. Fulltext. Click here to view fulltext PDF. Permanent link:

  16. Measurement and adjustment of dumb-bells for 9-cell TESLA cavity

    International Nuclear Information System (INIS)

    Xu Wencan; Quan Shengwen; Hao Jiankui; Jiang Tao; Zhang Baocheng; Zhao Kui

    2008-01-01

    Correct Dumb-bells are very important to make sure the right field flatness, frequency of TM010 mode and length of 9-cell TESLA cavity. The shape of the dumb-bells will be wrong due to deep drawing, machining and EB welding. Then, the dumb-bells should be adjusted after iris and stiffness welding according to the mechanical and microwave measurement. Peking University has set up facilities for measuring and correcting the dumb-bells. This paper discusses the method of measuring and correcting the dumb-bells. (authors)

  17. 3-Tesla MRI: Beneficial visualization of the meniscofemoral ligaments?

    Science.gov (United States)

    Ebrecht, Johanna; Krasny, Andrej; Hartmann, Dinah Maria; Rückbeil, Marcia Viviane; Ritz, Thomas; Prescher, Andreas

    2017-10-01

    Recent investigations have confirmed an important stabilizing and protective function of the meniscofemoral ligaments (MFLs) to the knee joint and suggest a clinical relevance. Concerning their incidences, however, there have been discrepancies between data acquired from cadaveric studies and MRI data using 0.3- to 1.5-Tesla field strengths probably due to lower resolution. This study aims to investigate whether imaging with 3-Tesla magnetic resonance imaging (3-T MRI) is beneficial in gaining information regarding the ligaments' incidence, length, width and anatomic variation. 3-T MRI images of 448 patients (224 males, 224 females, with, respectively, 32 patients of each sex in the age groups: 0-20, 21-30, 31-40, 41-50, 51-60, 61-70, >70years) were retrospectively reviewed. The influence of the parameters 'sex' and 'age' was determined. Whereas 71% of the patients had at least one MFL, 22% had an anterior MFL (aMFL), 53% had a posterior MFL (pMFL) and five percent had coexisting ligaments. The pMFLs were more likely to be present in female patients (P<0.05) but if so, they were longer in the males (P<0.05). The pMFL was categorized according to its insertion on the medial femoral condyle. 3-T MRI enables an excellent illustration of the anatomic variations of pMFLs. By modifying an anatomic classification for radiological use we measured lengths and widths of the MFLs without any difficulties. Despite its increased resolution, 3-T MRI lends no diagnostic benefit in visualizing the course of the aMFL or filigree coexisting ligaments as compared to MRI at lower field strengths. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Further investigations of the upper critical field and the high field critical current density in Nb-Ti and its alloys

    International Nuclear Information System (INIS)

    Hawksworth, D.G.; Larbalestier, D.C.

    1980-09-01

    This paper reports further measurements of Hc 2 in the Nb-Ti-Ta and Nb-Ti-Hf systems. Whilst we find only small enhancements of approx. 0.3 Tesla in μ 0 Hc 2 (4.2 0 K) compared to binary Nb-Ti, at 2 0 K there is a wide composition range in the Nb-Ti-Ta system where μ 0 Hc 2 (2 0 K) exceeds 15 Tesla, reaching a maximum of 15.5 Tesla. This represents an enhancement of 1.3 Tesla over unalloyed Nb-Ti. By comparison alloys in the Nb-Ti-Hf system show a maximum enhancement in μ 0 Hc 2 (2 0 K) of only 0.3 Tesla. The reasons both for the enhancements in Hc 2 and for the differences in behavior shown by alloys containing Ta and Hf are briefly discussed. This paper also discusses common features in the behavior of the high field critical current density, J/sub c/, of four commercial Nb-Ti composites and upon the basis of this behavior predict the enhancements in high field J/sub c/ to be expected from using Nb-Ti-Ta and its alloys

  19. Performance estimation of Tesla turbine applied in small scale Organic Rankine Cycle (ORC) system

    International Nuclear Information System (INIS)

    Song, Jian; Gu, Chun-wei; Li, Xue-song

    2017-01-01

    Highlights: • One-dimensional model of the Tesla turbine is improved and applied in ORC system. • Working fluid properties and system operating conditions impact efficiency. • The influence of turbine efficiency on ORC system performance is evaluated. • Potential of using Tesla turbine in ORC systems is estimated. - Abstract: Organic Rankine Cycle (ORC) system has been proven to be an effective method for the low grade energy utilization. In small scale applications, the Tesla turbine offers an attractive option for the organic expander if an efficient design can be achieved. The Tesla turbine is simple in structure and is easy to be manufactured. This paper improves the one-dimensional model for the Tesla turbine, which adopts a non-dimensional formulation that identifies the dimensionless parameters that dictates the performance features of the turbine. The model is used to predict the efficiency of a Tesla turbine that is applied in a small scale ORC system. The influence of the working fluid properties and the operating conditions on the turbine performance is evaluated. Thermodynamic analysis of the ORC system with different organic working fluids and under various operating conditions is conducted. The simulation results reveal that the ORC system can generate a considerable net power output. Therefore, the Tesla turbine can be regarded as a potential choice to be applied in small scale ORC systems.

  20. High magnetic field μSR instrument scientific case

    International Nuclear Information System (INIS)

    Amato, A.

    2005-10-01

    In order to gain more insight into the specific behavior of materials, it is often necessary to perform measurements as a function of different external parameters. Despite its high sensitivity to internal fields, this simple observation also applies for the μSR technique. The most common parameter which can be tuned during an experiment is the sample temperature. By using a range of cryostats, temperatures between 0.02 and 900 K can be covered at the PSI μSR Facility. On the other hand, and by using high-energy muons, pressures as high as 10'000 bars can nowadays be reached during μSR experiments. As will be demonstrated in the following Sections, the magnetic field is an additional external parameter playing a fundamental role when studying the ground state properties of materials in condensed matter physics and chemistry. However, the availability of high magnetic fields for μSR experiments is still rather limited. Hence, if on one hand the high value of the gyromagnetic ratio of the muon provides the high magnetic sensitivity of the method, on the other hand it can lead to very high muon-spin precession frequencies when performing measurements in applied fields (the muon-spin precession frequency in a field of 1 Tesla s 135.5 MHz). Consequently, the use of ultra-fast detectors and electronics is mandatory when measuring in magnetic fields exceeding 1 Tesla. If such fields are very intense when compared to the Earth magnetic field -4 Tesla), the energy associated with them is still modest in view of the thermal energy. Hence, the Zeeman energy splitting of a free electron in a magnetic field of 1 Tesla corresponds to a thermal energy as low as 0.67 Kelvin. It is worth mentioning that nowadays magnetic fields of the order of 10 to 15 Tesla are quite common in condensed matter laboratories and have opened up vast new exciting experimental possibilities. (author)

  1. High magnetic field {mu}SR instrument scientific case

    Energy Technology Data Exchange (ETDEWEB)

    Amato, A

    2005-10-15

    In order to gain more insight into the specific behavior of materials, it is often necessary to perform measurements as a function of different external parameters. Despite its high sensitivity to internal fields, this simple observation also applies for the {mu}SR technique. The most common parameter which can be tuned during an experiment is the sample temperature. By using a range of cryostats, temperatures between 0.02 and 900 K can be covered at the PSI {mu}SR Facility. On the other hand, and by using high-energy muons, pressures as high as 10'000 bars can nowadays be reached during {mu}SR experiments. As will be demonstrated in the following Sections, the magnetic field is an additional external parameter playing a fundamental role when studying the ground state properties of materials in condensed matter physics and chemistry. However, the availability of high magnetic fields for {mu}SR experiments is still rather limited. Hence, if on one hand the high value of the gyromagnetic ratio of the muon provides the high magnetic sensitivity of the method, on the other hand it can lead to very high muon-spin precession frequencies when performing measurements in applied fields (the muon-spin precession frequency in a field of 1 Tesla s 135.5 MHz). Consequently, the use of ultra-fast detectors and electronics is mandatory when measuring in magnetic fields exceeding 1 Tesla. If such fields are very intense when compared to the Earth magnetic field < 10{sup -4} Tesla), the energy associated with them is still modest in view of the thermal energy. Hence, the Zeeman energy splitting of a free electron in a magnetic field of 1 Tesla corresponds to a thermal energy as low as 0.67 Kelvin. It is worth mentioning that nowadays magnetic fields of the order of 10 to 15 Tesla are quite common in condensed matter laboratories and have opened up vast new exciting experimental possibilities. (author)

  2. The Legacy of Nikola Tesla

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 12; Issue 3. The Legacy of Nikola Tesla - The AC System that he Helped to Usher in. D P Sen Gupta. General Article Volume 12 Issue 3 March 2007 pp 54-69. Fulltext. Click here to view fulltext PDF. Permanent link:

  3. 3 tesla magnetic resonance imaging in children and adults with congenital heart disease; 3-Tesla-Magnetresonanztomographie zur Untersuchung von Kindern und Erwachsenen mit angeborenen Herzfehlern

    Energy Technology Data Exchange (ETDEWEB)

    Voges, I.; Hart, C.; Kramer, H.H.; Rickers, C. [Universitaetsklinikum Schleswig-Holstein, Klinik fuer angeborene Herzfehler und Kinderkardiologie, Kiel (Germany); Jerosch-Herold, M. [Harvard Medical School, Department of Radiology, Brigham and Women' s Hospital, Boston (United States); Helle, M. [Universitaetsklinikum Schleswig-Holstein, Institut fuer Neuroradiologie, Kiel (Germany)

    2010-09-15

    Cardiovascular magnetic resonance imaging (CMR) has become a routinely used imaging modality for congenital heart disease. A CMR examination allows the assessment of thoracic anatomy, global and regional cardiac function, blood flow in the great vessels and myocardial viability and perfusion. In the clinical routine cardiovascular MRI is mostly performed at field strengths of 1.5 Tesla (T). Recently, magnetic resonance systems operating at a field strengths of 3 T became clinically available and can also be used for cardiovascular MRI. The main advantage of CMR at 3 T is the gain in the signal-to-noise ratio resulting in improved image quality and/or allowing higher acquisition speed. Several further differences compared to MRI systems with lower field strengths have to be considered for practical applications. This article describes the impact of CMR at 3 T in patients with congenital heart disease by meanings of methodical considerations and case studies. (orig.) [German] Die kardiovaskulaere Magnetresonanztomographie (MRT) hat sich zu einer etablierten bildgebenden Methode zur Untersuchung von Patienten mit angeborenen Herzfehlern entwickelt. Sie erlaubt in einer einzigen Untersuchung die exakte Beurteilung von Anatomie, globaler und regionaler Funktion, Blutfluessen sowie der myokardialen Perfusion und Vitalitaet. In der klinischen Routine erfolgen die Untersuchungen zumeist bei einer Feldstaerke von 1,5 Tesla (T), mittlerweile gibt es jedoch Geraete und Bildgebungstechniken, die die kardiovaskulaere MRT auch bei 3 T ermoeglichen. Der wesentliche Vorteil der MRT bei 3 T ist das hoehere Signal-zu-Rausch-Verhaeltnis, das sowohl zu einer Verbesserung der Bildqualitaet als auch zu einer Verkuerzung der Untersuchungszeit genutzt werden kann. Darueber hinaus bestehen verschiedene andere Unterschiede gegenueber Systemen mit niedriger Feldstaerke, die im praktischen Einsatz beachtet werden muessen. Dieser Artikel beschreibt die Erfahrungen der 3-T-MRT fuer die

  4. Optoelectronics in TESLA, LHC and pi-of-the-sky experiments

    CERN Document Server

    Romaniuk, Ryszard; Simrock, Stefan; Wrochna, Grzegorz

    2004-01-01

    Optical and optoelectronics technologies are more and more widely used in the biggest world experiments of high energy and nuclear physics, as well as in the astronomy. The paper is a kind of a broad digest describing the usage of optoelectronics is such experiments and information about some of the involved teams. The described experiments include: TESLA linear accelerator and FEL, Compact Muon Solenoid at LHC and recently started pi-of-the-sky global gamma ray bursts (with associated optical flashes) observation experiment. Optoelectronics and photonics offer several key features which are either extending the technical parameters of existing solutions or adding quite new practical application possibilities. Some of these favorable features of photonic systems are: high selectivity of optical sensors, immunity to some kinds of noise processes, extremely broad bandwidth exchangeable for either terabit rate transmission or ultrashort pulse generation, parallel image processing capability, etc. The following g...

  5. Occipital cortical proton MRS at 4 Tesla in human moderate MDMA polydrug users

    OpenAIRE

    Cowan, Ronald L.; Bolo, Nicolas R.; Dietrich, Mary; Haga, Erica; Lukas, Scott E.; Renshaw, Perry F.

    2007-01-01

    The recreational drug MDMA (3,4, methylenedioxymethamphetamine; sold under the street name of Ecstasy) is toxic to serotonergic axons in some animal models of MDMA administration. In humans, MDMA use is associated with alterations in markers of brain function that are pronounced in occipital cortex. Among neuroimaging methods, magnetic resonance spectroscopy (MRS) studies of brain metabolites N-acetylaspartate (NAA) and myoinositol (MI) at a field strength of 1.5 Tesla (T) reveal inconsistent...

  6. A Laminar Flow-Based Microfluidic Tesla Pump via Lithography Enabled 3D Printing

    Directory of Open Access Journals (Sweden)

    Mohammed-Baker Habhab

    2016-11-01

    Full Text Available Tesla turbine and its applications in power generation and fluid flow were demonstrated by Nicholas Tesla in 1913. However, its real-world implementations were limited by the difficulty to maintain laminar flow between rotor disks, transient efficiencies during rotor acceleration, and the lack of other applications that fully utilize the continuous flow outputs. All of the aforementioned limits of Tesla turbines can be addressed by scaling to the microfluidic flow regime. Demonstrated here is a microscale Tesla pump designed and fabricated using a Digital Light Processing (DLP based 3D printer with 43 µm lateral and 30 µm thickness resolutions. The miniaturized pump is characterized by low Reynolds number of 1000 and a flow rate of up to 12.6 mL/min at 1200 rpm, unloaded. It is capable of driving a mixer network to generate microfluidic gradient. The continuous, laminar flow from Tesla turbines is well-suited to the needs of flow-sensitive microfluidics, where the integrated pump will enable numerous compact lab-on-a-chip applications.

  7. A Laminar Flow-Based Microfluidic Tesla Pump via Lithography Enabled 3D Printing.

    Science.gov (United States)

    Habhab, Mohammed-Baker; Ismail, Tania; Lo, Joe Fujiou

    2016-11-23

    Tesla turbine and its applications in power generation and fluid flow were demonstrated by Nicholas Tesla in 1913. However, its real-world implementations were limited by the difficulty to maintain laminar flow between rotor disks, transient efficiencies during rotor acceleration, and the lack of other applications that fully utilize the continuous flow outputs. All of the aforementioned limits of Tesla turbines can be addressed by scaling to the microfluidic flow regime. Demonstrated here is a microscale Tesla pump designed and fabricated using a Digital Light Processing (DLP) based 3D printer with 43 µm lateral and 30 µm thickness resolutions. The miniaturized pump is characterized by low Reynolds number of 1000 and a flow rate of up to 12.6 mL/min at 1200 rpm, unloaded. It is capable of driving a mixer network to generate microfluidic gradient. The continuous, laminar flow from Tesla turbines is well-suited to the needs of flow-sensitive microfluidics, where the integrated pump will enable numerous compact lab-on-a-chip applications.

  8. Interference with cardiac pacemakers by magnetic resonance imaging: are there irreversible changes at 0.5 Tesla?

    Science.gov (United States)

    Vahlhaus, C; Sommer, T; Lewalter, T; Schimpf, R; Schumacher, B; Jung, W; Lüderitz, B

    2001-04-01

    The safety and feasibility of magnetic resonance imaging (MRI) in patients with cardiac pacemakers is an issue of gaining significance. The effect of MRI on patients' pacemaker systems has only been analyzed retrospectively in some case reports. Therefore, this study prospectively investigated if MRI causes irreversible changes in patients' pacemaker systems. The effect of MRI at 0.5 Tesla on sensing and stimulation thresholds, lead impedance and battery voltage, current, and impedance was estimated during 34 MRI examinations in 32 patients with implanted pacemakers. After measurements at baseline and with documentation of intrinsic rhythm and modification of the pacing mode, patients underwent MRI. The rest of the function time of the pacemaker was calculated. Measurements were again performed after 99.5 +/- 29.6 minutes (mean +/- SD), immediately after MRI examination, and 3 months later. Lead impedance and sensing and stimulation thresholds did not change after MRI. Battery voltage decreased immediately after MRI and recovered 3 months later. Battery current and impedance tended to increase. The calculated rest of function time did not change immediately after MRI. MRI affected neither pacemaker programmed data, nor the ability to interrogate, program, or use telemetry. Surprisingly, in the gantry of the scanner, temporary deactivation of the reed switch occurred in 12 of 32 patients when positioned in the center of the magnetic field. Missing activation of the reed switch through the static magnetic field at 0.5 Tesla is not unusual. MRI at 0.5 Tesla does not cause irreversible changes in patients' pacemaker systems.

  9. Superconducting 63-Pole 2 Tesla Wiggler for Canadian Light Source

    International Nuclear Information System (INIS)

    Khruschev, S.V.; Kuper, E.A.; Lev, V.H.; Mezentsev, N.A.; Miginsky, E.G.; Repkov, V.V.; Shkaruba, B.A.; Syrovatin, V.M.; Tsukanov, V.M.

    2006-01-01

    A superconducting 63-pole wiggler with the average period 34 mm designed and fabricated at the Institute of Nuclear Physics in Novosibirsk for Synchrotron Radiation Center (CLS) in Canada is described. The maximum field 2.2 Tesla in the median plane has been achieved. The liquid helium consumption less than 0.03 liters per hour in operating mode has been reached. In January 2005, the wiggler was installed in the storage ring in CLS and now experiments are already underway. The main parameters of the magnet and the cryogenic systems as well as test results are presented

  10. Travelling wave accelerating structure design for TESLA positron injector linac

    CERN Document Server

    Jin, K; Zhou, F; Flöttmann, K

    2000-01-01

    A modified cup-like TW accelerating structure for TESLA Positron Pre-Accelerator (PPA) is designed by optimizing the structure geometry and by changing the iris thickness cell by cell in a section . This structure has high shunt-impedance and a large iris radius to meet with the requirements of high gradient and large transverse acceptance. The beam dynamics in the structure with the optimum solenoid focus field are studied. A satisfactory positron beam transmission and the beam performance at the PPA output have been obtained. In this paper the accelerating structure design is described in detail and the results are presented.

  11. Comparison of different undulator schemes with superimposed alternating gradients for the VUV-FEL at the TESLA Test Facility

    Energy Technology Data Exchange (ETDEWEB)

    Pflueger, J.; Nikitina, Y.M. [DESY/HASYLAB, Hamburg (Germany)

    1995-12-31

    For the VUV-FEL at the TESLA Test Facility an undulator with a total length of 30 m is needed. In this study three different approaches to realize an undulator with a sinusoidal plus a superimposed quadrupolar field were studied with the 3D code MAFIA.

  12. Ultra-high-field magnets for future hadron colliders

    International Nuclear Information System (INIS)

    McIntyre, P.M.; Shen, W.

    1997-01-01

    Several new concepts in magnetic design and coil fabrication are being incorporated into designs for ultra-high field collider magnets: a 16 Tesla block-coil dual dipole, also using Nb 3 Sn cable, featuring simple pancake coil construction and face-loaded prestress geometry; a 330 T/m block-coil quadrupole; and a ∼ 20 Tesla pipe-geometry dual dipole, using A15 or BSCCO tape. Field design and fabrication issues are discussed for each magnet

  13. Harmonized technical standards in the nuclear field

    International Nuclear Information System (INIS)

    Carbone, Ferdinando

    1976-01-01

    The need was felt of harmonizing and gradually standardizing technical norms, from the well-known Anglo-Saxon type codes of practice to the equally well-known recommendations of the International Commission on Radiological Protection (ICRP). The latter provide the basis for the Euratom Directives (basic standards), which, following their adoption, were embodied in the national laws of community Member countries. ISO (International Standardization Organization) is active in the nuclear technical regulations field, in particular through its Committee ISO/TC 85 ''Nuclear Energy'' at international level and, in Italy, through the National Italian Unification Agency (UNI) and its Nuclear Unification Commission (UNICEN). At its XI plenary meeting this body, on the proposal of the Secretary-General, set up a Study Group to promote revision of the regulation in force and coordination between legislation and development of UNICEN standards, considered as a set of integrative industrial technical standards. CISDEN, the Italian Nuclear Energy Forum (FIEN) and other interested organizations have been invited to collaborate in this work. (N.E.A.)

  14. TESLA accelerator installation

    International Nuclear Information System (INIS)

    Neskovic, N.; Ostojic, R.; Susini, A.; Milinkovic, Lj.; Ciric, D.; Dobrosavljevic, A.; Brajuskovic, B.; Cirkovic, S.; Bojovic, B.; Josipovic, M.

    1992-01-01

    The TESLA accelerator Installation is described. Its main parts are the VINCY Cyclotron, the multiply charged heavy-ion mVINIS Ion Source, and the negative light-ion pVINIS Ion Source. The Installation should be the principal installation of a regional center for basic and applied research in nuclear physics, atomic physics, surface physics and solid state physics, for production of radioisotopes, for research and therapy in nuclear medicine. The first extraction of the ion beam from the Cyclotron is planned for 1995. (R.P.) 3 refs.; 1 fig

  15. Operating experience with superconducting cavities at the TESLA test facility

    International Nuclear Information System (INIS)

    Moeller, Wolf-Dietrich

    2003-01-01

    A description of the TESLA Test Facility, which has been set up at DESY by the TeV Energy Superconducting Accelerator (TESLA) collaboration, will be given as it is now after five years of installation and operation. The experience with the first three modules, each containing 8 superconducting 9-cell cavities, installed and operated in the TTF-linac will be described. The measurements in the vertical and horizontal cryostats as well as in the modules will be compared. Recent results of the operation at the TESLA design current, macropulses of 800 μsec with bunches of 3.2 nC at a rate of 2.25 MHz are given. New measurement results of the higher order modes (HOM) will be presented. The operation and optimisation of the TTF Free Electron Laser (TTF-FEL) will also be covered in this paper. (author)

  16. In vivo high-resolution 7 Tesla MRI shows early and diffuse cortical alterations in CADASIL.

    Science.gov (United States)

    De Guio, François; Reyes, Sonia; Vignaud, Alexandre; Duering, Marco; Ropele, Stefan; Duchesnay, Edouard; Chabriat, Hugues; Jouvent, Eric

    2014-01-01

    Recent data suggest that early symptoms may be related to cortex alterations in CADASIL (Cerebral Autosomal-Dominant Arteriopathy with Subcortical Infarcts and Leukoencephalopathy), a monogenic model of cerebral small vessel disease (SVD). The aim of this study was to investigate cortical alterations using both high-resolution T2* acquisitions obtained with 7 Tesla MRI and structural T1 images with 3 Tesla MRI in CADASIL patients with no or only mild symptomatology (modified Rankin's scale ≤1 and Mini Mental State Examination (MMSE) ≥24). Complete reconstructions of the cortex using 7 Tesla T2* acquisitions with 0.7 mm isotropic resolution were obtained in 11 patients (52.1±13.2 years, 36% male) and 24 controls (54.8±11.0 years, 42% male). Seven Tesla T2* within the cortex and cortical thickness and morphology obtained from 3 Tesla images were compared between CADASIL and control subjects using general linear models. MMSE, brain volume, cortical thickness and global sulcal morphology did not differ between groups. By contrast, T2* measured by 7 Tesla MRI was significantly increased in frontal, parietal, occipital and cingulate cortices in patients after correction for multiple testing. These changes were not related to white matter lesions, lacunes or microhemorrhages in patients having no brain atrophy compared to controls. Seven Tesla MRI, by contrast to state of the art post-processing of 3 Tesla acquisitions, shows diffuse T2* alterations within the cortical mantle in CADASIL whose origin remains to be determined.

  17. In vivo high-resolution 7 Tesla MRI shows early and diffuse cortical alterations in CADASIL.

    Directory of Open Access Journals (Sweden)

    François De Guio

    Full Text Available Recent data suggest that early symptoms may be related to cortex alterations in CADASIL (Cerebral Autosomal-Dominant Arteriopathy with Subcortical Infarcts and Leukoencephalopathy, a monogenic model of cerebral small vessel disease (SVD. The aim of this study was to investigate cortical alterations using both high-resolution T2* acquisitions obtained with 7 Tesla MRI and structural T1 images with 3 Tesla MRI in CADASIL patients with no or only mild symptomatology (modified Rankin's scale ≤1 and Mini Mental State Examination (MMSE ≥24.Complete reconstructions of the cortex using 7 Tesla T2* acquisitions with 0.7 mm isotropic resolution were obtained in 11 patients (52.1±13.2 years, 36% male and 24 controls (54.8±11.0 years, 42% male. Seven Tesla T2* within the cortex and cortical thickness and morphology obtained from 3 Tesla images were compared between CADASIL and control subjects using general linear models.MMSE, brain volume, cortical thickness and global sulcal morphology did not differ between groups. By contrast, T2* measured by 7 Tesla MRI was significantly increased in frontal, parietal, occipital and cingulate cortices in patients after correction for multiple testing. These changes were not related to white matter lesions, lacunes or microhemorrhages in patients having no brain atrophy compared to controls.Seven Tesla MRI, by contrast to state of the art post-processing of 3 Tesla acquisitions, shows diffuse T2* alterations within the cortical mantle in CADASIL whose origin remains to be determined.

  18. Conclusion: probable and possible futures. MRI with ultra high magnetic field

    International Nuclear Information System (INIS)

    Le Bihan, D.

    2009-01-01

    MR neuroimaging does not interfere with brain function. Because it is safe, it can be used to study the brains of both patients and healthy volunteers. The tasks performed by neurons depend largely on their precise location, and high-field magnets have the potential to provide a 5- to 10-fold increase in spatio-temporal resolution. This should allow brain function to be studied on a scale of only a few thousand neurons, possibly at the intermediate scale of the 'neural code'. NeuroSpin, a new CEA research center, is dedicated to neuro-MRI at high magnetic field strengths. As a forum for dialogue between those developing and those using these instruments, it brings together researchers and engineers, technicians and medical doctors. NeuroSpin is one of the few institutions in Europe, if not the world, where these experts can come together in one place to design, construct and use machines equipped with ultra-strong magnets. The strongest 'routine' MR device currently operates at 3 Tesla (60 000 times the earth's magnetic field), whereas a first French system operating at 7 Tesla (140 000 times the earth's field) is now available for human studies, and another system operating at 11.7 Tesla (world record) should be delivered in 2011. Preclinical studies are also being conducted with magnets operating at 7 Tesla and, soon, 17.6 Tesla. (author)

  19. Electron scattering with polarized targets at TESLA

    International Nuclear Information System (INIS)

    Anselmino, M.; Aschenauer, E.C.; Belostotski, S.

    2000-11-01

    Measurements of polarized electron-nucleon scattering can be realized at the TESLA linear collider facility with projected luminosities that are about two orders of magnitude higher than those expected of other experiments at comparable energies. Longitudinally polarized electrons, accelerated as a small fraction of the total current in the e + arm of TESLA, can be directed onto a solid state target that may be either longitudinally or transversely polarized. A large variety of polarized parton distribution and fragmentation functions can be determined with unprecedented accuracy, many of them for the first time. A main goal of the experiment is the precise measurement of the x- and Q 2 -dependence of the experimentally totally unknown quark transversity distributions that will complete the information on the nucleon's quark spin structure as relevant for high energy processes. Comparing their Q 2 -evolution to that of the corresponding helicity distributions constitutes an important precision test of the predictive power of QCD in the spin sector. Measuring transversity distributions and tensor charges allows access to the hitherto unmeasured chirally odd operators in QCD which are of great importance to understand the role of chiral symmetry. The possibilities of using unpolarized targets and of experiments with a real photon beam turn TESLA-N into a versatile next-generation facility at the intersection of particle and nuclear physics. (orig.)

  20. Lumbar Modic Changes - A Comparison Between Findings at Low-and High-field MRI

    DEFF Research Database (Denmark)

    Bendix, Tom; Sorensen, Joan S; Henriksson, Gustaf A C

    2012-01-01

    Study Design. A cross-sectional observational study.Objective. To investigate if there is a difference in findings of lumbar Modic changes in low-field (0.3 Tesla) magnetic resonance imaging (MRI) as compared to high field (1.5 Tesla).Summary of Background Data. It is a challenge to give patients...

  1. Horizontal nystagmus and multiple sclerosis using 3-Tesla magnetic resonance imaging.

    Science.gov (United States)

    Iyer, P M; Fagan, A J; Meaney, J F; Colgan, N C; Meredith, S D; Driscoll, D O; Curran, K M; Bradley, D; Redmond, J

    2016-11-01

    Nystagmus in patients with multiple sclerosis (MS) is generally attributed to brainstem disease. Lesions in other regions may result in nystagmus. The identification of these other sites is enhanced by using 3-Tesla magnetic resonance imaging (3TMRI) due to increased signal-to-noise ratio. We sought to evaluate the distribution of structural lesions and disruption of tracts in patients with horizontal nystagmus secondary to MS using 3TMRI. Twenty-four patients (20 women, 4 men; age range 26-55 years) with horizontal nystagmus secondary to MS underwent 3TMRI brain scans; and 18 patients had diffusion tensor imaging (DTI) for tractography. Nystagmus was bidirectional in 11, right-sided in 6 and left-sided in 7. We identified 194 lesions in 20 regions within the neural integrator circuit in 24 patients; 140 were within the cortex and 54 were within the brainstem. Only two patients had no lesions in the cortex, and 9 had no lesions in the brainstem. There was no relationship between side of lesion and direction of nystagmus. Thirteen of 18 (72 %) had tract disruption with fractional anisotropy (FA) values below 0.2. FA was significantly lower in bidirectional compared to unidirectional nystagmus (p = 0.006). In MS patients with horizontal nystagmus, lesions in all cortical eye fields and their descending connections were evident. Technical improvements in tractography may help identify the specific site(s) resulting in nystagmus in MS.

  2. Gadolinium-based magnetic resonance contrast agents at 7 Tesla: in vitro T1 relaxivities in human blood plasma.

    Science.gov (United States)

    Noebauer-Huhmann, Iris M; Szomolanyi, Pavol; Juras, Vladimír; Kraff, Oliver; Ladd, Mark E; Trattnig, Siegfried

    2010-09-01

    PURPOSE/INTRODUCTION: The aim of this study was to determine the T1 relaxivities (r1) of 8 gadolinium (Gd)-based MR contrast agents in human blood plasma at 7 Tesla, compared with 3 Tesla. Eight commercially available Gd-based MR contrast agents were diluted in human blood plasma to concentrations of 0, 0.25, 0.5, 1, and 2 mmol/L. In vitro measurements were performed at 37 degrees C, on a 7 Tesla and on a 3 Tesla whole-body magnetic resonance imaging scanner. For the determination of T1 relaxation times, Inversion Recovery Sequences with inversion times from 0 to 3500 ms were used. The relaxivities were calculated. The r1 relaxivities of all agents, diluted in human blood plasma at body temperature, were lower at 7 Tesla than at 3 Tesla. The values at 3 Tesla were comparable to those published earlier. Notably, in some agents, a minor negative correlation of r1 with a concentration of up to 2 mmol/L could be observed. This was most pronounced in the agents with the highest protein-binding capacity. At 7 Tesla, the in vitro r1 relaxivities of Gd-based contrast agents in human blood plasma are lower than those at 3 Tesla. This work may serve as a basis for the application of Gd-based MR contrast agents at 7 Tesla. Further studies are required to optimize the contrast agent dose in vivo.

  3. MR appearances of intracranial tumors with a low tesla (0.064 T) permanent MR system

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hee Jin; Lim, Sun Kyung; Kwon, Dae Ik; Kim, Byung Young; Lee, Jong Gil [Fatima Hospital, Taegu (Korea, Republic of)

    1993-09-15

    In this report we describe twenty-two cases of intracranial tumors studied with an MR imager operating at a field strength of 0.064 T for evaluation of the clinical utility of low tesla MRI. The confirmed diagnoses were meningioma(9 cases), astrocytoma(4 cases), glioblastoma multiforme (1 case), craniopharyngioma(2 cases), intracranial metastasis(1 cases), pituitary microadenomal(1 cases), hemangioblastoma(1 cases), and trigerminal neurilemmoma(1 cases). Meningiomas appeared as well-marginated, homogeneous signal intensity masses (67%) in most cases. Most meningiomas showed iso-signal intensity(78%) on T1-weighted images, and high signal intensity on T2-weighted images. After Gd-DTPA enhancement, diffuse homogeneous contrast enhancement(75%) was well seen. The mutiple hemorrhage foci within the glioblastoma multiforme were identified, which showed high signal intensity on T1-weighted images and low signal intensity on T2-weighted images(intracellular methemoglobin) or high signal intensity on both T1 and T2-weighted images(extracellular methemoglobin). One case of cerebellar hemangioblastoma was a well- defined cystic mass with contrast enhanced mural nodule but no identification of characteristic signal void vessels. The remaining tumors showed low signal intensity on T1-weighted images, and high signal intensity on T2-weighted images. Gd-DTPA enhancement was helpful in separating the lesion from the surrounding edema or normal tissue, but had limited diagnostic value in characterizing the nature of the mass. The advantage of low tesla MRI are as follows: on requirement of cooling water or electricity, open design, shorter T1 relaxation time compared with high tesla unit that increases the difference of T1-relaxation time between tissues, ease of installation, and cost effectiveness. In conclusion, The low tesla MRI is useful for the detection and evaluation of the brain tumors.

  4. MR appearances of intracranial tumors with a low tesla (0.064 T) permanent MR system

    International Nuclear Information System (INIS)

    Kim, Hee Jin; Lim, Sun Kyung; Kwon, Dae Ik; Kim, Byung Young; Lee, Jong Gil

    1993-01-01

    In this report we describe twenty-two cases of intracranial tumors studied with an MR imager operating at a field strength of 0.064 T for evaluation of the clinical utility of low tesla MRI. The confirmed diagnoses were meningioma(9 cases), astrocytoma(4 cases), glioblastoma multiforme (1 case), craniopharyngioma(2 cases), intracranial metastasis(1 cases), pituitary microadenomal(1 cases), hemangioblastoma(1 cases), and trigerminal neurilemmoma(1 cases). Meningiomas appeared as well-marginated, homogeneous signal intensity masses (67%) in most cases. Most meningiomas showed iso-signal intensity(78%) on T1-weighted images, and high signal intensity on T2-weighted images. After Gd-DTPA enhancement, diffuse homogeneous contrast enhancement(75%) was well seen. The mutiple hemorrhage foci within the glioblastoma multiforme were identified, which showed high signal intensity on T1-weighted images and low signal intensity on T2-weighted images(intracellular methemoglobin) or high signal intensity on both T1 and T2-weighted images(extracellular methemoglobin). One case of cerebellar hemangioblastoma was a well- defined cystic mass with contrast enhanced mural nodule but no identification of characteristic signal void vessels. The remaining tumors showed low signal intensity on T1-weighted images, and high signal intensity on T2-weighted images. Gd-DTPA enhancement was helpful in separating the lesion from the surrounding edema or normal tissue, but had limited diagnostic value in characterizing the nature of the mass. The advantage of low tesla MRI are as follows: on requirement of cooling water or electricity, open design, shorter T1 relaxation time compared with high tesla unit that increases the difference of T1-relaxation time between tissues, ease of installation, and cost effectiveness. In conclusion, The low tesla MRI is useful for the detection and evaluation of the brain tumors

  5. Wakefield and RF Kicks Due to Coupler Asymmetry in TESLA-Type Accelerating Cavities

    International Nuclear Information System (INIS)

    Bane, K

    2008-01-01

    In a future linear collider, such as the International Linear Collider (ILC), trains of high current, low emittance bunches will be accelerated in a linac before colliding at the interaction point. Asymmetries in the accelerating cavities of the linac will generate fields that will kick the beam transversely and degrade the beam emittance and thus the collider performance. In the main linac of the ILC, which is filled with TESLA-type superconducting cavities, it is the fundamental (FM) and higher mode (HM) couplers that are asymmetric and thus the source of such kicks. The kicks are of two types: one, due to (the asymmetry in) the fundamental RF fields and the other, due to transverse wakefields that are generated by the beam even when it is on axis. In this report we calculate the strength of these kicks and estimate their effect on the ILC beam. The TESLA cavity comprises nine cells, one HM coupler in the upstream end, and one (identical, though rotated) HM coupler and one FM coupler in the downstream end (for their shapes and location see Figs. 1, 2) [1]. The cavity is 1.1 m long, the iris radius 35 mm, and the coupler beam pipe radius 39 mm. Note that the couplers reach closer to the axis than the irises, down to a distance of 30 mm

  6. Prostate cancer detection by prebiopsy 3.0-tesla magnetic resonance imaging

    International Nuclear Information System (INIS)

    Nishida, Sachiyo; Kinoshita, Hidefumi; Mishima, Takao; Kurokawa, Hiroaki; Sakaida, Noriko; Matsuda, Tadashi

    2011-01-01

    The diagnostic value of 3.0-Tesla magnetic resonance imaging (MRI) for prostate cancer remains to be determined. The aim of the present study was to assess the features of prostate cancer detectable by prebiopsy 3.0-Tesla MRI. From January 2007 through to December 2008, 116 patients who were examined by prebiopsy 3.0-Tesla MRI underwent radical prostatectomy for localized prostate cancer. Prostate specimens were examined to see whether the largest cancer area was the same as the area indicated on the MRI. Univariate and multivariate logistic regression analyses were conducted to identify variables predictive of agreement between MRI and histopathological findings. Sixty-six (56.9%) patients were suspected of having prostate cancer on the basis of MRI findings. In 49 of these patients (74.2%), it was considered that there was agreement between the abnormal area on the MRI and the index tumor. Univariate analysis revealed that there were significant differences in abnormal digital rectal examination, capsular penetration, the diameter of the index tumor of the radical prostatectomy specimen, and the Gleason scores of the biopsy and radical prostatectomy specimens. Multivariate analysis revealed that the Gleason score of the radical prostatectomy specimen was associated with the accurate detection of the prostate cancer by MRI (P=0.0177). In conclusion, 3.0-Tesla MRI tends to accurately diagnose prostate cancer with high tumor burden and aggressiveness. Multimodal examination (T2-weighted imaging, dynamic contrast-enhanced imaging, and diffusion-weighted imaging) is recommended for the diagnosis of prostate cancer using 3.0-Tesla MRI. (author)

  7. Overview of electrical axis measurement in TESLA-type cavities

    International Nuclear Information System (INIS)

    Labanc, Anton

    2007-01-01

    The cells of TESLA cavities are mechanically aligned and tuned before the cavities are installed into the cryomodule. The alignment minimizes unwanted interaction of the accelerated beam with the transverse electric field component and the magnetic field of the accelerating TM 010 -π mode. It also reduces an interaction with higher order modes. The tuning equalizes field amplitudes of the accelerating mode in all cells. Until now, the eccentricity (misalignment) of cells is measured mechanically with residual misalignment after tuning up to 0.4 mm. Unfortunately the mechanical measurement is only weakly related to the electromagnetic fields inside a cavity, both for the accelerating and higher order modes. For improvement of the precision a new method of electromagnetic field mapping inside a cavity, based on small perturbation theory was developed. This method can be applied to modes which do not propagate through the beam pipes. In the setup built for the axis measurement a metallic needle is used as field perturbing object. Conducted tests confirmed high precision of 0.1 mm. Tests on the copper model for which it is possible to excite all of considered modes and on several niobium cavities were performed. In this paper an overview of measurement method, equipment and first results are reported. (orig.)

  8. 76 FR 60118 - Tesla Motors, Inc. Grant of Petition for Renewal of a Temporary Exemption From the Advanced Air...

    Science.gov (United States)

    2011-09-28

    ...-0070] Tesla Motors, Inc. Grant of Petition for Renewal of a Temporary Exemption From the Advanced Air... Protection. SUMMARY: This notice grants the petition of Tesla Motors, Inc. (Tesla) for the renewal of a... the one for Tesla. Over time, the number of petitions for exemption from the advanced air bag...

  9. Theoretical and Experimental Research Performed on the Tesla Turbine - Part I

    Directory of Open Access Journals (Sweden)

    Dorian Nedelcu

    2015-09-01

    Full Text Available The paper presents the theoretical and experimental research performed on a Tesla turbine driven by compressed air and designed to equip a teaching laboratory [1], [2]. It introduces the operating principle of the Tesla turbine, which was invented by engineer Nikola Tesla, a turbine which uses discs instead of blades, mounted on a shaft at a small distance between them. The turbine geometry, results from stress and flow calculations performed on the turbine rotor and assembly, using the Simulation modules and SolidWorks Flow Simulation program are presented. After designing the turbine, it becomes the subject of experimental research to determine the curve of the speed depending on the pressure. Also, the experimental research focuses on the behaviour of the turbine from a dynamic point of view [3].

  10. Nikola Tesla: Why was he so much resisted and forgotten? [Retrospectroscope].

    Science.gov (United States)

    Valentinuzzi, Max E; Ortiz, Martin Hill; Cervantes, Daniel; Leder, Ron S

    2016-01-01

    Recently, during the Christmas season, a friend of mine visited me and, sneaking a look at my bookshelves, found two rather old Nikola Tesla biographies, which I had used to prepare a "Retrospectroscope" column for the then-named IEEE Engineering in Medicine and Biology Magazine when our dear friend Alvin Wald was its editor-inchief [2]. Eighteen years have elapsed since then; soon, the idea came up of revamping the article. Cynthia Weber, the magazine's current associate editor, considered it acceptable, and here is the new note divided in two parts: that is, a slightly revised version of the original article followed by new material, including some quite interesting information regarding Tesla's homes and laboratories. On top of this, Tesla is not devoid of a science fiction touch, as mentioned at the end.

  11. Dynamic Multi-Coil Shimming of the Human Brain at 7 Tesla

    Science.gov (United States)

    Juchem, Christoph; Nixon, Terence W.; McIntyre, Scott; Boer, Vincent O.; Rothman, Douglas L.; de Graaf, Robin A.

    2011-01-01

    High quality magnetic field homogenization of the human brain (i.e. shimming) for MR imaging and spectroscopy is a demanding task. The susceptibility differences between air and tissue are a longstanding problem as they induce complex field distortions in the prefrontal cortex and the temporal lobes. To date, the theoretical gains of high field MR have only been realized partially in the human brain due to limited magnetic field homogeneity. A novel shimming technique for the human brain is presented that is based on the combination of non-orthogonal basis fields from 48 individual, circular coils. Custom-built amplifier electronics enabled the dynamic application of the multi-coil shim fields in a slice-specific fashion. Dynamic multi-coil (DMC) shimming is shown to eliminate most of the magnetic field inhomogeneity apparent in the human brain at 7 Tesla and provided improved performance compared to state-of-the-art dynamic shim updating with zero through third order spherical harmonic functions. The novel technique paves the way for high field MR applications of the human brain for which excellent magnetic field homogeneity is a prerequisite. PMID:21824794

  12. NIKOLA TESLA AND MEDICINE: 160TH ANNIVERSARY OF THE BIRTH OF THE GENIUS WHO GAVE LIGHT TO THE WORLD - PART II.

    Science.gov (United States)

    Vucevic, Danijela; Dordevic, Drago; Radosavljevic, Tatjana

    2016-11-01

    Nikola Tesla (1856- 1943) was a genius inventor and scientist, whose contribution to medicine is remarkable. Part I of this article reviewed special contributions of the world renowned scientist to the establishment of radiology as a new discipline in medicine. This paper deals with the use of Tesla currents in medicine. Tesla Currents in Medicine. Tesla's greatest impact on medicine is his invention of a transformer (Tesla coil) for producing high frequency and high voltage currents (Tesla currents). Tesla currents are used in diathermy, as they, while passing through the body, transform electrical energy into a therapeutic heat. In 1891, Tesla passed currents through his own body and was the first to experience their beneficial effects. He kept correspondence on electrotherapy with J. Dugan and S. H. Monell. In 1896, he used high frequency currents and designed an ozone generator for producing ozone, with powerful antiseptic and antibacterial properties. Tesla is famous for his extensive experiments with mechanical vibrations and resonance, examining their effects on the organ ism and pioneering their use for medical purposes. Tesla also designed an oscillator to relieve fatigue of the leg muscles. It is less known that Tesla's inventions (Tesla coil and wireless remote control) are widely used in modern medical equipment. Apart from this, wireless technology is nowadays widely applied in numerous diagnostic and therapeutic procedures. Nikola Tesla was the last Renais- sance figure of the modern era. Tesla bridged three centuries and two millennia by his inventions, and permanently indebted humankind by his epochal discoveries.

  13. Endometrium evaluation with high-field (3-Tesla) magnetic resonance imaging in patients submitted to uterine leiomyoma embolization

    International Nuclear Information System (INIS)

    Jacobs, Monica Amadio Piazza; Nasser, Felipe; Zlotnik, Eduardo; Messina, Marcos de Lorenzo; Baroni, Ronaldo Hueb

    2013-01-01

    To evaluate the endometrial alterations related to embolization of uterine arteries for the treatment of symptomatic uterine leiomyomatosis (pelvic pain and/or uterine bleeding) by means of high-field (3-Tesla) magnetic resonance. This is a longitudinal and prospective study that included 94 patients with a clinical and imaging diagnosis of symptomatic uterine leiomyomatosis, all of them treated by embolization of the uterine arteries. The patients were submitted to evaluations by high-field magnetic resonance of the pelvis before and 6 months after the procedure. Specific evaluations were made of the endometrium on the T2-weighted sequences, and on the T1-weighted sequences before and after the intravenous dynamic infusion of the paramagnetic contrast. In face of these measures, statistical analyses were performed using Student's t test for comparison of the results obtained before and after the procedure. An average increase of 20.9% was noted in the endometrial signal on T2-weighted images obtained after the uterine artery embolization procedure when compared to the pre-procedure evaluation (p=0.0004). In the images obtained with the intravenous infusion of paramagnetic contrast, an average increase of 18.7% was noted in the post-embolization intensity of the endometrial signal, compared to the pre-embolization measure (p<0.035). After embolization of the uterine arteries, there was a significant increase of the endometrial signal on the T2-weighted images and on the post-contrast images, inferring possible edema and increased endometrial flow. Future studies are needed to assess the clinical impact of these findings

  14. Endometrium evaluation with high-field (3-Tesla) magnetic resonance imaging in patients submitted to uterine leiomyoma embolization

    Energy Technology Data Exchange (ETDEWEB)

    Jacobs, Monica Amadio Piazza [Post-graduation Program in Abdominal Imaging, Hospital Israelita Albert Einstein, São Paulo, SP (Brazil); Nasser, Felipe [Intervention Radiology Department, Hospital Israelita Albert Einstein, São Paulo, SP (Brazil); Zlotnik, Eduardo; Messina, Marcos de Lorenzo [Gynecology and Obstetrics Department, Hospital Israelita Albert Einstein, São Paulo, SP (Brazil); Baroni, Ronaldo Hueb [Magnetic Resonance Unit, Imaging Department, Hospital Israelita Albert Einstein, São Paulo, SP (Brazil)

    2013-07-01

    To evaluate the endometrial alterations related to embolization of uterine arteries for the treatment of symptomatic uterine leiomyomatosis (pelvic pain and/or uterine bleeding) by means of high-field (3-Tesla) magnetic resonance. This is a longitudinal and prospective study that included 94 patients with a clinical and imaging diagnosis of symptomatic uterine leiomyomatosis, all of them treated by embolization of the uterine arteries. The patients were submitted to evaluations by high-field magnetic resonance of the pelvis before and 6 months after the procedure. Specific evaluations were made of the endometrium on the T2-weighted sequences, and on the T1-weighted sequences before and after the intravenous dynamic infusion of the paramagnetic contrast. In face of these measures, statistical analyses were performed using Student's t test for comparison of the results obtained before and after the procedure. An average increase of 20.9% was noted in the endometrial signal on T2-weighted images obtained after the uterine artery embolization procedure when compared to the pre-procedure evaluation (p=0.0004). In the images obtained with the intravenous infusion of paramagnetic contrast, an average increase of 18.7% was noted in the post-embolization intensity of the endometrial signal, compared to the pre-embolization measure (p<0.035). After embolization of the uterine arteries, there was a significant increase of the endometrial signal on the T2-weighted images and on the post-contrast images, inferring possible edema and increased endometrial flow. Future studies are needed to assess the clinical impact of these findings.

  15. Tilt optimized flip uniformity (TOFU) RF pulse for uniform image contrast at low specific absorption rate levels in combination with a surface breast coil at 7 Tesla

    NARCIS (Netherlands)

    van Kalleveen, Irene M. L.; Boer, VO; Luijten, Peter R.; Klomp, DWJ

    Purpose: Going to ultrahigh field MRI (e. g., 7 Tesla [ T]), the nonuniformity of the B_1 field and the increased radiofrequency (RF) power deposition become challenging. While surface coils improve the power efficiency in B_1, its field remains nonuniform. In this work, an RF pulse was designed

  16. Design and performance of a Tesla transformer type relativistic electron beam generator

    International Nuclear Information System (INIS)

    Jain, K.K.; Chennareddy, D.; John, P.I.; Saxena, Y.C.

    1986-01-01

    A relativistic electron beam generator driven by an air core Tesla transformer is described. The Tesla transformer circuit analysis is outlined and computational results are presented for the case when the coaxial water line has finite resistance. The transformer has a coupling coefficient of 0.56 and a step-up ratio of 25. The Tesla transformer can provide 800 kV at the peak of the second half cycle of the secondary output voltage and has been tested up to 600 kV. A 100-200 keV, 15-20 kA electron beam having 150 ns pulse width has been obtained. The beam generator described is being used for the beam injection into a toroidal device BETA. (author). 20 refs. 9 figures

  17. Magnetic field measurement system of the VINCY Cyclotron

    International Nuclear Information System (INIS)

    Dobrosavljevic, A.; Cirkovic, S.; Zdravkovic, A.; Urosevic, Z.; Lucic, M.; Gemaljevic, M.

    1995-01-01

    This paper presents the magnetic field measurement system of the VINCY Cyclotron, main part of the TESLA accelerator installation whose construction has been going on in the Vinca Institute of Nuclear Sciences. Measurement system consists of mechanical structure and control unit for the automatic positioning of the measurement probe in the median plane, between the poles of the magnet, and corresponding measuring instrumentation, based on two digital tesla meters. Concept of the measurement system is defined by the TESLA team, while realisation of the measurement system is performed in co-operation with the LOLA Institute. (author)

  18. Genotoxic Effects of Superconducting Static Magnetic Fields (SMFs) on Wheat (Triticum aestivum) Pollen Mother Cells (PMCs)

    Science.gov (United States)

    Zhang, Pingping; Yin, Ruochun; Chen, Zhiyou; Wu, Lifang; Yu, Zengliang

    2007-04-01

    The effects of superconducting static magnetic fields (SMFs) on the pollen mother cells (PMCs) of wheat were investigated in order to evaluate the possible genotoxic effect of such non-ionizing radiation. The seeds of wheat were exposed to static magnetic fields with either different magnetic flux densities (0, 1, 3, 5 and 7 Tesla) for 5 h or different durations (1, 3 and 5 h) at a magnetic flux density of 7 Tesla. The seeds were germinated at 23oC after exposure and the seedlings were transplanted into the field. The PMCs from young wheat ears were taken and slides were made following the conventional method. The genotoxic effect was evaluated in terms of micronucleus (MN), chromosomal bridge, lagging chromosome and fragments in PMCs. Although the exposed groups of a low field intensity (below 5 Tesla) showed no statistically significant difference in the aberration frequency compared with the unexposed control groups and sham exposed groups, a significant increase in the chromosomal bridge, lagging chromosome, triple-polar segregation or micronucleus was observed at a field strength of 5 Tesla or 7 Tesla, respectively. The analysis of dose-effect relationships indicated that the increased frequency of meiotic abnormal cells correlated with the flux density of the magnetic field and duration, but no linear relationship was observed. Such statistically significant differences indicated a potential genotoxic effect of high static magnetic fields above 5 T.

  19. Genotoxic Effects of Superconducting Static Magnetic Fields (SMFs) on Wheat (Triticum aestivum) Pollen Mother Cells (PMCs)

    International Nuclear Information System (INIS)

    Zhang Pingping; Yin Ruochun; Chen Zhiyou; Wu Lifang; Yu Zengliang

    2007-01-01

    The effects of superconducting static magnetic fields (SMFs) on the pollen mother cells (PMCs) of wheat were investigated in order to evaluate the possible genotoxic effect of such non-ionizing radiation. The seeds of wheat were exposed to static magnetic fields with either different magnetic flux densities (0, 1, 3, 5 and 7 Tesla) for 5 h or different durations (1, 3 and 5 h) at a magnetic flux density of 7 Tesla. The seeds were germinated at 23 o C after exposure and the seedlings were transplanted into the field. The PMCs from young wheat ears were taken and slides were made following the conventional method. The genotoxic effect was evaluated in terms of micronucleus (MN), chromosomal bridge, lagging chromosome and fragments in PMCs. Although the exposed groups of a low field intensity (below 5 Tesla) showed no statistically significant difference in the aberration frequency compared with the unexposed control groups and sham exposed groups, a significant increase in the chromosomal bridge, lagging chromosome, triple-polar segregation or micronucleus was observed at a field strength of 5 Tesla or 7 Tesla, respectively. The analysis of dose-effect relationships indicated that the increased frequency of meiotic abnormal cells correlated with the flux density of the magnetic field and duration, but no linear relationship was observed. Such statistically significant differences indicated a potential genotoxic effect of high static magnetic fields above 5 T

  20. TeSLA presentatie voor medewerkers van AMN

    NARCIS (Netherlands)

    Janssen, José

    2017-01-01

    Presentatie over Online toetsen voor medewerkers van AMN (www.amn.nl). Topics: assessment onderzoek Welten-instituut en meer in het bijzonder het TeSLA project waarin instrumenten voor authenticatie en auteurschap verificatie worden gecombineerd om betrouwbaar toetsen op afstand mogelijk te maken.

  1. Women’s Participation in Scientific and Technical Field in Malaysia

    OpenAIRE

    Nuraihan Mat Daud

    1999-01-01

    The scientific and technical fields are generally dominated by men. Women tend to shy away from using technical devices and from trying to understand the principles behind their operation. One of the major reasons for their seemingly lack of interest is the lack of encouragement from their family and society. This paper discusses the steps taken by a country, namely, Malaysia, to encourage its female population to venture into this area. Policies were created by the government for this purpos...

  2. Hippocampal MRI volumetry at 3 Tesla: reliability and practical guidance.

    Science.gov (United States)

    Jeukens, Cécile R L P N; Vlooswijk, Mariëlle C G; Majoie, H J Marian; de Krom, Marc C T F M; Aldenkamp, Albert P; Hofman, Paul A M; Jansen, Jacobus F A; Backes, Walter H

    2009-09-01

    Although volumetry of the hippocampus is considered to be an established technique, protocols reported in literature are not described in great detail. This article provides a complete and detailed protocol for hippocampal volumetry applicable to T1-weighted magnetic resonance (MR) images acquired at 3 Tesla, which has become the standard for structural brain research. The protocol encompasses T1-weighted image acquisition at 3 Tesla, anatomic guidelines for manual hippocampus delineation, requirements of delineation software, reliability measures, and criteria to assess and ensure sufficient reliability. Moreover, the validity of the correction for total intracranial volume size was critically assessed. The protocol was applied by 2 readers to the MR images of 36 patients with cryptogenic localization-related epilepsy, 4 patients with unilateral hippocampal sclerosis, and 20 healthy control subjects. The uncorrected hippocampal volumes were 2923 +/- 500 mm3 (mean +/- SD) (left) and 3120 +/- 416 mm3 (right) for the patient group and 3185 +/- 411 mm3 (left) and 3302 +/- 411 mm3 (right) for the healthy control group. The volume of the 4 pathologic hippocampi of the patients with unilateral hippocampal sclerosis was 2980 +/- 422 mm3. The inter-reader reliability values were determined: intraclass-correlation-coefficient (ICC) = 0.87 (left) and 0.86 (right), percentage volume difference (VD) = 7.0 +/- 4.7% (left) and 6.0 +/- 3.8% (right), and overlap ratio (OR) = 0.82 +/- 0.04 (left) and 0.82 +/- 0.03 (right). The positive Pearson correlation between hippocampal volume and total intracranial volume was found to be low: r = 0.48 (P = 0.03, left) and r = 0.62 (P = 0.004, right) and did not significantly reduce the volumetric variances, showing the limited benefit of the brain size correction. A protocol was described to determine hippocampal volumes based on 3 Tesla MR images with high inter-reader reliability. Although the reliability of hippocampal volumetry at 3 Tesla

  3. Identification of the Key Fields and Their Key Technical Points of Oncology by Patent Analysis.

    Science.gov (United States)

    Zhang, Ting; Chen, Juan; Jia, Xiaofeng

    2015-01-01

    This paper aims to identify the key fields and their key technical points of oncology by patent analysis. Patents of oncology applied from 2006 to 2012 were searched in the Thomson Innovation database. The key fields and their key technical points were determined by analyzing the Derwent Classification (DC) and the International Patent Classification (IPC), respectively. Patent applications in the top ten DC occupied 80% of all the patent applications of oncology, which were the ten fields of oncology to be analyzed. The number of patent applications in these ten fields of oncology was standardized based on patent applications of oncology from 2006 to 2012. For each field, standardization was conducted separately for each of the seven years (2006-2012) and the mean of the seven standardized values was calculated to reflect the relative amount of patent applications in that field; meanwhile, regression analysis using time (year) and the standardized values of patent applications in seven years (2006-2012) was conducted so as to evaluate the trend of patent applications in each field. Two-dimensional quadrant analysis, together with the professional knowledge of oncology, was taken into consideration in determining the key fields of oncology. The fields located in the quadrant with high relative amount or increasing trend of patent applications are identified as key ones. By using the same method, the key technical points in each key field were identified. Altogether 116,820 patents of oncology applied from 2006 to 2012 were retrieved, and four key fields with twenty-nine key technical points were identified, including "natural products and polymers" with nine key technical points, "fermentation industry" with twelve ones, "electrical medical equipment" with four ones, and "diagnosis, surgery" with four ones. The results of this study could provide guidance on the development direction of oncology, and also help researchers broaden innovative ideas and discover new

  4. Nucleonic instruments from VUPJT Tesla

    International Nuclear Information System (INIS)

    Smola, J.

    1986-01-01

    The instruments currently produced by Tesla Premysleni are listed and briefly characterized. They include a low level alpha-beta counter, an automatic low level alpha-beta counter, detection units for environmental sample counting, instruments for measuring specific activity of liquids and radon concentration in water, a radioactive aerosol meter, dose ratemeters, portable alpha-beta indicators for surface contamintion monitoring, neutron monitors, single-, two- and three-channel spectrometric units. (M.D.)

  5. Functional magnetic resonance imaging with ultra-high fields

    International Nuclear Information System (INIS)

    Windischberger, C.; Schoepf, V.; Sladky, R.; Moser, E.; Fischmeister, F.P.S.

    2010-01-01

    Functional magnetic resonance imaging (fMRI) is currently the primary method for non-invasive functional localization in the brain. With the emergence of MR systems with field strengths of 4 Tesla and above, neuronal activation may be studied with unprecedented accuracy. In this article we present different approaches to use the improved sensitivity and specificity for expanding current fMRT resolution limits in space and time based on several 7 Tesla studies. In addition to the challenges that arise with ultra-high magnetic fields possible solutions will be discussed. (orig.) [de

  6. Note: Tesla based pulse generator for electrical breakdown study of liquid dielectrics

    Science.gov (United States)

    Veda Prakash, G.; Kumar, R.; Patel, J.; Saurabh, K.; Shyam, A.

    2013-12-01

    In the process of studying charge holding capability and delay time for breakdown in liquids under nanosecond (ns) time scales, a Tesla based pulse generator has been developed. Pulse generator is a combination of Tesla transformer, pulse forming line, a fast closing switch, and test chamber. Use of Tesla transformer over conventional Marx generators makes the pulse generator very compact, cost effective, and requires less maintenance. The system has been designed and developed to deliver maximum output voltage of 300 kV and rise time of the order of tens of nanoseconds. The paper deals with the system design parameters, breakdown test procedure, and various experimental results. To validate the pulse generator performance, experimental results have been compared with PSPICE simulation software and are in good agreement with simulation results.

  7. Cortical microinfarcts detected in vivo on 3 Tesla MRI: clinical and radiological correlates.

    Science.gov (United States)

    van Dalen, Jan Willem; Scuric, Eva E M; van Veluw, Susanne J; Caan, Matthan W A; Nederveen, Aart J; Biessels, Geert Jan; van Gool, Willem A; Richard, Edo

    2015-01-01

    Cortical microinfarcts (CMIs) are a common postmortem finding associated with vascular risk factors, cognitive decline, and dementia. Recently, CMIs identified in vivo on 7 Tesla MRI also proved retraceable on 3 Tesla MRI. We evaluated CMIs on 3 Tesla MRI in a population-based cohort of 194 nondemented older people (72-80 years) with systolic hypertension. Using a case-control design, participants with and without CMIs were compared on age, sex, cardiovascular risk factors, and white matter hyperintensity volume. We identified 23 CMIs in 12 participants (6%). CMIs were associated with older age, higher diastolic blood pressure, and a history of recent stroke. There was a trend for a higher white matter hyperintensity volume in participants with CMIs. We found an association of CMIs with clinical parameters, including age and cardiovascular risk factors. Although the prevalence of CMIs is relatively low, our results suggest that the study of CMIs in larger clinical studies is possible using 3 Tesla MRI. This opens the possibility of large-scale prospective investigation of the clinical relevance of CMIs in older people. © 2014 American Heart Association, Inc.

  8. Design of the 1.8 Tesla wiggler for the DAΦNE Main Rings

    International Nuclear Information System (INIS)

    Sanelli, C.; Hsieh, H.

    1992-01-01

    The electromagnetic and mechanical design of the eight wiggler magnets for DAΦNE Main Rings is described. The wigglers have a large 1.8 Tesla flat top magnetic field, 64 cm period and 4 cm gap. The magnetic 3-D calculations, the electromagnetic design and the adopted mechanical solutions, with particular attention to the vacuum chamber problems are described. A full scale prototype (5 full poles and two half pole) will be constructed in order to verify the accuracy of magnetic calculations, the end pole design and the multipole content. (author) 4 figs.; 1 tab

  9. NIKOLA TESLA AND MEDICINE: 160TH ANNIVERSARY OF THE BIRTH OF THE GENIUS WHO GAVE LIGHT TO THE WORLD - PART I.

    Science.gov (United States)

    Vucevic, Danijela; Dordevic, Drago; Radosavljevic, Tatjana

    2016-09-01

    The interest in Nikola Tesla, a scientist, physicist, engineer and inventor, is constantly growing. In the millennialong history of human civilization, it is almost impossible to find another person whose life and work has been under so much scrutiny of such a wide range of researchers, medical professionals included. Although Tesla was not primarily dedicated to biomedical research, his work significantly contributed to the development of radiology, and high frequency electrotherapy. This paper deals with the impact of Tesla's work on the development of a new medical branch - radiology. Nikola Tesla and the Discovery of X-ray radiation. Tesla pioneered the use of X-rays for medical purposes, practically laying the foundations of radiology. Namely, since 1887, Tesla periodically experimented with X-rays, at that time still unknown and unnamed, which he called "shadowgraphs". Moreover, at the end of 1894, lie conducted extensive research focusing on X-rays, but unfortunately it was inlerrupted after the fire burning down his laboratory in 1895. In 1896 and 1897, Tesla published ten papers on the biologic effects of X-ray radiation. All his studies on X-rays were experimental. During 1896 and 1897, Tesla continued improving X-ray devices. Apart from this, Tesla was the first to point out the harmful effects of exposure to X-ray radiation on human body. Nikola Tesla was a visionary genius of the future. Tesla's pioneer steps, made more than a century ago in the domain of radiology, are still being used today.

  10. Diagnosis of rotator cuff tears using 3-Tesla MRI versus 3-Tesla MRA: a systematic review and meta-analysis.

    Science.gov (United States)

    McGarvey, Ciaran; Harb, Ziad; Smith, Christian; Houghton, Russell; Corbett, Steven; Ajuied, Adil

    2016-02-01

    To compare the diagnostic accuracy of magnetic resonance imaging (MRI), 2-dimensional magnetic resonance arthrogram (MRA) and 3-dimensional isotropic MRA in the diagnosis of rotator cuff tears when performed exclusively at 3-T. A systematic review was undertaken of the Cochrane, MEDLINE and PubMed databases in accordance with the PRISMA guidelines. Studies comparing 3-T MRI or 3-T MRA (index tests) to arthroscopic surgical findings (reference test) were included. Methodological appraisal was performed using QUADAS 2. Pooled sensitivity and specificity were calculated and summary receiver-operating curves generated. Kappa coefficients quantified inter-observer reliability. Fourteen studies comprising 1332 patients were identified for inclusion. Twelve studies were retrospective and there were concerns regarding index test bias and applicability in nine and six studies respectively. Reference test bias was a concern in all studies. Both 3-T MRI and 3-T MRA showed similar excellent diagnostic accuracy for full-thickness supraspinatus tears. Concerning partial-thickness supraspinatus tears, 3-T 2D MRA was significantly more sensitive (86.6 vs. 80.5 %, p = 0.014) but significantly less specific (95.2 vs. 100 %, p Tesla 3D isotropic MRA showed similar accuracy to 3-T conventional 2D MRA. Three-Tesla MRI appeared equivalent to 3-T MRA in the diagnosis of full- and partial-thickness tears, although there was a trend towards greater accuracy in the diagnosis of subscapularis tears with 3-T MRA. Three-Tesla 3D isotropic MRA appears equivalent to 3-T 2D MRA for all types of tears.

  11. 12 tesla test coil. Annual progress report

    International Nuclear Information System (INIS)

    1979-01-01

    The Plasma Fusion Center at MIT has been charged with responsibility for the design, development, fabrication and test operation of a Niobium-3-Tin Superconducting Test Coil. Research is described on DOE's 12 tesla coil demonstration program in which several one-meter diameter superconducting test coils will be inserted and tested in DOE's High Field Test Facility at the Lawrence Livermore Laboratories. The work was initiated at the start of FY 79. FY 79 saw the completion of our Preliminary Design and the initiation of three (3) subcontracts: (1) Westinghouse review of the Preliminary Design, (II) Supercon, Inc. development of a tubular copper matrix, Nb 3 Sn Superconductor and (III) Airco optimization of the LCP-W Nb 3 Sn superconductor for 12T service. In addition, Airco was charged with the production of a 1000 foot length of model 15,000A conductor. Coil winding exercises were initiated at the Everson Electric Company

  12. Nikola Tesla and medicine: 160th anniversary of the birth of the genius who gave light to the world - Part II

    OpenAIRE

    Vučević, Danijela; Đorđević, Drago; Radosavljević, Tatjana

    2016-01-01

    Introduction. Nikola Tesla (1856 - 1943) was a genius inventor and scientist, whose contribution to medicine is remarkable. Part I of this article reviewed special contributions of the world renowned scientist to the establishment of radiology as a new discipline in medicine. This paper deals with the use of Tesla currents in medicine. Tesla Currents in Medicine. Tesla's greatest impact on medicine is his invention of a transformer (Tesla coil) for producing high frequency and high voltage cu...

  13. Diagnostic usefulness of 3 tesla MRI of the brain for cushing disease in a child.

    Science.gov (United States)

    Ono, Erina; Ozawa, Ayako; Matoba, Kaori; Motoki, Takanori; Tajima, Asako; Miyata, Ichiro; Ito, Junko; Inoshita, Naoko; Yamada, Syozo; Ida, Hiroyuki

    2011-10-01

    It is sometimes difficult to confirm the location of a microadenoma in Cushing disease. Recently, we experienced an 11-yr-old female case of Cushing disease with hyperprolactinemia. She was referred to our hospital because of decrease of height velocity with body weight gain. On admission, she had typical symptoms of Cushing syndrome. Although no pituitary microadenomas were detected on 1.5 Tesla MRI of the brain, endocrinological examinations including IPS and CS sampling were consistent with Cushing disease with hyperprolactinemia. Oral administration of methyrapone instead of neurosurgery was started after discharge, but subsequent 3 Tesla MRI of the brain clearly demonstrated a 3-mm less-enhanced lesion in the left side of the pituitary gland. Finally, transsphenoidal surgery was performed, and a 3.5-mm left-sided microadenoma was resected. Compared with 1.5 Tesla MRI, 3 Tesla MRI offers the advantage of a higher signal to noise ratio (SNR), which provides higher resolution and proper image quality. Therefore, 3 Tesla MRI is a very useful tool to localize microadenomas in Cushing disease in children as well as in adults. It will be the first choice of radiological examinations in suspected cases of Cushing disease.

  14. Specific heat of single crystalline YBa2Cu3O7 in 20 Tesla

    International Nuclear Information System (INIS)

    Bonjour, E.; Calemczuk, R.; Henry, J.Y.; Muller, J.; Triscone, G.; Vallier, J.C.

    1993-01-01

    The specific heat of a single crystal of YBa 2 Cu 3 0 7 is measured from 40 to 150 K in magnetic fields up to 20 Tesla applied either parallel or normal to the c axis. Adiabatic calorimetry with a scatter well below 0.1% is used. The scaling of the superconducting transitions determines the bulk anisotropy ratio 5.5±0.5. A Maki-like term is observed at intermediate temperatures. The unusual behaviour of YBa 2 Cu 3 0 7 in a field, featuring a considerable smearing of the transition and an apparently field-independent onset, may be qualitatively understood as a phenomenological consequence of the small and anisotropic value of the coherence length alone, using the relevant models of field-induced critical I-D fluctuations on one hand, and London-like regime for the mean-field part of the transition on the other hand

  15. Specific heat of single crystalline YBa2Cu3O7 in 20 Tesla

    International Nuclear Information System (INIS)

    Junod, A.; Bonjour, E.; Calemczuk, R.; Henry, J.Y.; Muller, J.; Triscone, G.; Vallier, J.C.

    1994-01-01

    The specific heat of a single crystal of YBa 2 Cu 3 O 7 is measured from 40 to 150 K in magnetic fields up to 20 Tesla applied either parallel or normal to the c axis. Adiabatic calorimetry with a scatter well below 0.1% is used. The scaling of the superconducting transitions determines the bulk anisotropy ratio, 5.5±0.5. A Maki-like term is observed at intermediate temperatures. The unusual behaviour of YBa 2 Cu 3 O 7 in a field, featuring a considerable smearing of the transition and an apparently field-independent onset, may be qualitatively understood as a phenomenological consequence of the small and anisotropic value of the coherence length alone, using the relevant models of field-induced critical 1-D fluctuations on one hand, and London-like regime for the mean-field part of the transition on the other hand. (orig.)

  16. 76 FR 33402 - Tesla Motors, Inc.; Receipt of Petition for Renewal of Temporary Exemption from the Advanced Air...

    Science.gov (United States)

    2011-06-08

    ...-0070] Tesla Motors, Inc.; Receipt of Petition for Renewal of Temporary Exemption from the Advanced Air... Protection. SUMMARY: In accordance with the procedures in 49 CFR Part 555, Tesla Motors, Inc., has petitioned... Petition In accordance with 49 U.S.C. 30113 and the procedures in 49 CFR Part 555, Tesla Motors, Inc...

  17. Simulation Model solves exact the Enigma named Generating high Voltages and high Frequencies by Tesla Coil

    OpenAIRE

    Simo Janjanin

    2016-01-01

    Simulation model of Tesla coil has been successfully completed, and has been verified the procedure and functioning. The literature and documentation for the model were taken from the rich sources, especially the copies of Tesla patents. The oscillating system‟s electrical scheme consists of the voltage supply 220/50 Hz, Fe transformer, capacitor and belonging chosen electrical components, the air gap in the primary Tesla coil (air transformer) and spark gap in the exit of the coil. The inves...

  18. MEASUREMENT OF THE TRANSVERSE BEAM DYNAMICS IN A TESLA-TYPE SUPERCONDUCTING CAVITY

    Energy Technology Data Exchange (ETDEWEB)

    Halavanau, A. [NICADD, DeKalb; Eddy, N. [Fermilab; Edstrom, D. [Fermilab; Lunin, A. [Fermilab; Piot, P. [NICADD, DeKalb; Ruan, J. [Fermilab; Solyak, N. [Fermilab

    2016-09-26

    Superconducting linacs are capable of producing intense, ultra-stable, high-quality electron beams that have widespread applications in Science and Industry. Many project are based on the 1.3-GHz TESLA-type superconducting cavity. In this paper we provide an update on a recent experiment aimed at measuring the transfer matrix of a TESLA cavity at the Fermilab Accelerator Science and Technology (FAST) facility. The results are discussed and compared with analytical and numerical simulations.

  19. Optimization of materials for the parts that compose a Tesla turbine; Otimizacao de materiais para as partes que compoe uma turbina tipo Tesla

    Energy Technology Data Exchange (ETDEWEB)

    Rocha, Geovana Vilas Boas da, E-mail: geovana_dmp@yahoo.com.br [Universidade Federal de Sao Paulo (UNIFESP), Sao Jose dos Campos, SP (Brazil); Guimaraes, Lamartine N.F.; Placco, Guilherme M., E-mail: guimarae@ieav.cta.br, E-mail: placco@ieav.cta.br [Instituto de Estudos Avancados (IEAv), Sao Jose dos Campos, SP (Brazil). Divisao de Energia Nuclear

    2013-07-01

    The TERRA project (Tecnologia de Reatores Rapidos Avancados) of the Aeronautica (Brazil) aims to develop the necessary technologies for the design of nuclear microreactors. These, in turn, aim to address the thermal and electrical needs in space vehicles. One of the activities of this project is to build a closed thermal cycle, the Rankine type in order to test a Tesla turbine type developed by the group. In this thermodynamic cycle the water is transformed into steam, which triggers a turbine which, in turn, provide power to the alternator to be converted into electricity. The work presented a survey of the materials available on the national market for machining a Tesla type turbine. The surveys were made considering the characteristics and operating conditions of a specific thermal cycle, the interest of the group. Results: cost-benefit tables for each party of the turbine, characteristics of each material, the machining process, as well as a comparison between one of 304L stainless steel model turbine with a turbine with the selected materials. The results from this study raised the level of sophistication of the research involved the TERRA project, since the study of ideal materials that make up the parts of a Tesla type turbine in a heat cycle is unprecedented.

  20. Tesla's coherent plasma discharge -and- a plan for megavolts at Megahertz

    International Nuclear Information System (INIS)

    Nichson, J.D.

    1987-01-01

    In his lecture on Experiments With Alternate Currents of High Potential and High Frequency before the Institute of Electrical Engineers in London (1892), Tesla reports a discharge through a partially evacuated air tube of 1 meter length and 1 inch diameter. It is characterized by the following properties: (1) The filamentary discharge may be locally displaced by a nearby dielectric body or a magnet. (2) When the filament is released, it demonstrates behaviour similar to that of a string which suspends a weight, including the formation of standing waves with distinct nodes. (3) Its decay time is on the order of 8 minutes. (4) The vibrating filament may be split with a magnet to produce two vibrating filaments. (5) This effect could only be formed with a dynamo-driven coil at low air pressures in the tube. The disruptive discharge coil (coloquially a Tesla Coil) failed to produce the effect with its superior voltage and frequency range. It is here proposed that this phenomenon is related to positive leader formation. A model for this, consistent for AC and DC discharges, is advanced. Also, a novel method for regulation of a nitrogen-filled spark gap will be proposed. It is hoped that this new device will produce smooth, uniform discharges from the Tesla Coil. This, if theory is correct on many points, will reproduce Tesla's coherent plasma at higher pressures in free-standing form, and will allow other novel effects

  1. Oxygen-enhanced MRI of the lungs. Intraindividual comparison between 1.5 and 3 Tesla

    International Nuclear Information System (INIS)

    Dietrich, Olaf; Thieme, S.F.; Maxien, D.; Nikolaou, K.; Reiser, M.; Schoenberg, S.O.; Fink, C.

    2011-01-01

    Purpose: To assess the feasibility of oxygen-enhanced MRI of the lung at 3 Tesla and to compare signal characteristics with 1.5 Tesla. Materials and Methods: 13 volunteers underwent oxygen-enhanced lung MRI at 1.5 and 3 T with a T 1-weighted single-slice non-selective inversion-recovery single-shot half-Fourier fast-spin-echo sequence with simultaneous respiratory and cardiac triggering in coronal orientation. 40 measurements were acquired during room air breathing and subsequently during oxygen breathing (15 L/min, close-fitting face-mask). The signal-to-noise ratio (SNR) of the lung tissue was determined with a difference image method. The image quality of all acquisitions was visually assessed. The mean values of the oxygen-induced relative signal enhancement and its regional coefficient of variation were calculated and the signal enhancement was displayed as color-coded parameter maps. Oxygen-enhancement maps were visually assessed with respect to the distribution and heterogeneity of the oxygen-related signal enhancement at both field strengths. Results: The mean relative signal enhancement due to oxygen breathing was 13 % (± 5.6 %) at 1.5 T and of 9.0 % (± 8.0 %) at 3 T. The regional coefficient of variation was significantly higher at 3 T. Visual and quantitative assessment of the enhancement maps showed considerably less homogeneous distribution of the signal enhancement at 3 T. The SNR was not significantly different but showed a trend to slightly higher values (increase of about 10 %) at 3 T. Conclusion: Oxygen-enhanced pulmonary MRI is feasible at 3 Tesla. However, signal enhancement is currently more heterogeneous and slightly lower at 3 T. (orig.)

  2. Beam dynamic issues in TESLA damping ring

    International Nuclear Information System (INIS)

    Shiltsev, V.

    1996-05-01

    In this paper we study general requirements on impedances of the linear collider TESLA damping ring design. Quantitative consideration is performed for 17-km long ''dog-bone'' ring. Beam dynamics in alternative options of 6.3 and 2.3-km long damping rings is briefly discussed. 5 refs., 2 tabs

  3. Diagnosis of rotator cuff tears using 3-Tesla MRI versus 3-Tesla MRA: a systematic review and meta-analysis

    Energy Technology Data Exchange (ETDEWEB)

    McGarvey, Ciaran; Harb, Ziad; Smith, Christian; Ajuied, Adil [Guy' s and St Thomas' Hospital, King' s Health Partners, Department of Trauma and Orthopaedics, London (United Kingdom); Houghton, Russell [Guy' s and St Thomas' Hospital, King' s Health Partners, Department of Radiology, London (United Kingdom); Corbett, Steven [Guy' s and St Thomas' Hospital, King' s Health Partners, Department of Trauma and Orthopaedics, London (United Kingdom); Fortius Clinic, London (United Kingdom)

    2016-02-15

    To compare the diagnostic accuracy of magnetic resonance imaging (MRI), 2-dimensional magnetic resonance arthrogram (MRA) and 3-dimensional isotropic MRA in the diagnosis of rotator cuff tears when performed exclusively at 3-T. A systematic review was undertaken of the Cochrane, MEDLINE and PubMed databases in accordance with the PRISMA guidelines. Studies comparing 3-T MRI or 3-T MRA (index tests) to arthroscopic surgical findings (reference test) were included. Methodological appraisal was performed using QUADAS 2. Pooled sensitivity and specificity were calculated and summary receiver-operating curves generated. Kappa coefficients quantified inter-observer reliability. Fourteen studies comprising 1332 patients were identified for inclusion. Twelve studies were retrospective and there were concerns regarding index test bias and applicability in nine and six studies respectively. Reference test bias was a concern in all studies. Both 3-T MRI and 3-T MRA showed similar excellent diagnostic accuracy for full-thickness supraspinatus tears. Concerning partial-thickness supraspinatus tears, 3-T 2D MRA was significantly more sensitive (86.6 vs. 80.5 %, p = 0.014) but significantly less specific (95.2 vs. 100 %, p < 0.001). There was a trend towards greater accuracy in the diagnosis of subscapularis tears with 3-T MRA. Three-Tesla 3D isotropic MRA showed similar accuracy to 3-T conventional 2D MRA. Three-Tesla MRI appeared equivalent to 3-T MRA in the diagnosis of full- and partial-thickness tears, although there was a trend towards greater accuracy in the diagnosis of subscapularis tears with 3-T MRA. Three-Tesla 3D isotropic MRA appears equivalent to 3-T 2D MRA for all types of tears. (orig.)

  4. Diagnosis of rotator cuff tears using 3-Tesla MRI versus 3-Tesla MRA: a systematic review and meta-analysis

    International Nuclear Information System (INIS)

    McGarvey, Ciaran; Harb, Ziad; Smith, Christian; Ajuied, Adil; Houghton, Russell; Corbett, Steven

    2016-01-01

    To compare the diagnostic accuracy of magnetic resonance imaging (MRI), 2-dimensional magnetic resonance arthrogram (MRA) and 3-dimensional isotropic MRA in the diagnosis of rotator cuff tears when performed exclusively at 3-T. A systematic review was undertaken of the Cochrane, MEDLINE and PubMed databases in accordance with the PRISMA guidelines. Studies comparing 3-T MRI or 3-T MRA (index tests) to arthroscopic surgical findings (reference test) were included. Methodological appraisal was performed using QUADAS 2. Pooled sensitivity and specificity were calculated and summary receiver-operating curves generated. Kappa coefficients quantified inter-observer reliability. Fourteen studies comprising 1332 patients were identified for inclusion. Twelve studies were retrospective and there were concerns regarding index test bias and applicability in nine and six studies respectively. Reference test bias was a concern in all studies. Both 3-T MRI and 3-T MRA showed similar excellent diagnostic accuracy for full-thickness supraspinatus tears. Concerning partial-thickness supraspinatus tears, 3-T 2D MRA was significantly more sensitive (86.6 vs. 80.5 %, p = 0.014) but significantly less specific (95.2 vs. 100 %, p < 0.001). There was a trend towards greater accuracy in the diagnosis of subscapularis tears with 3-T MRA. Three-Tesla 3D isotropic MRA showed similar accuracy to 3-T conventional 2D MRA. Three-Tesla MRI appeared equivalent to 3-T MRA in the diagnosis of full- and partial-thickness tears, although there was a trend towards greater accuracy in the diagnosis of subscapularis tears with 3-T MRA. Three-Tesla 3D isotropic MRA appears equivalent to 3-T 2D MRA for all types of tears. (orig.)

  5. Diffusion-weighted whole-body MR imaging with background body signal suppression: a feasibility study at 3.0 Tesla

    International Nuclear Information System (INIS)

    Muertz, Petra; Krautmacher, Carsten; Traeber, Frank; Schild, Hans H.; Willinek, Winfried A.; Gieseke, Juergen

    2007-01-01

    The purpose was to provide a diffusion-weighted whole-body magnetic resonance (MR) imaging sequence with background body signal suppression (DWIBS) at 3.0 Tesla. A diffusion-weighted spin-echo echo-planar imaging sequence was combined with the following methods of fat suppression: short TI inversion recovery (STIR), spectral attenuated inversion recovery (SPAIR), and spectral presaturation by inversion recovery (SPIR). Optimized sequences were implemented on a 3.0- and a 1.5-Tesla system and evaluated in three healthy volunteers and six patients with various lesions in the neck, chest, and abdomen on the basis of reconstructed maximum intensity projection images. In one patient with metastases of malignant melanoma, DWIBS was compared with 18 F-fluorodeoxyglucose positron emission tomography (FDG-PET). Good fat suppression for all regions and diagnostic image quality in all cases could be obtained at 3.0 Tesla with the STIR method. In comparison with 1.5 Tesla, DWIBS images at 3.0 Tesla were judged to provide a better lesion-to-bone tissue contrast. However, larger susceptibility-induced image distortions and signal intensity losses, stronger blurring artifacts, and more pronounced motion artifacts degraded the image quality at 3.0 Tesla. A good correlation was found between the metastases as depicted by DWIBS and those as visualized by FDG-PET. DWIBS is feasible at 3.0 Tesla with diagnostic image quality. (orig.)

  6. First cold test of TESLA superconducting RF cavity in horizontal cryostat (CHECHIA)

    International Nuclear Information System (INIS)

    Kuzminski, J.

    1996-01-01

    In the framework of the TESLA project, the horizontal cryostat (CHECHIA) was built to test a superconducting RF cavity equipped with its helium vessel, magnetic shielding, cold tuner, main coupler and higher order modes couplers under realistic conditions before final assembly of eight cavities into TESLA Test Facility cryo-module. The results of the first cold tests in CHECHIA, performed at DESY with a 9-cell cavity (C19) to be used in the TTF injector are presented. (author)

  7. Paul Drude's prediction of nonreciprocal mutual inductance for Tesla transformers.

    Science.gov (United States)

    McGuyer, Bart

    2014-01-01

    Inductors, transmission lines, and Tesla transformers have been modeled with lumped-element equivalent circuits for over a century. In a well-known paper from 1904, Paul Drude predicts that the mutual inductance for an unloaded Tesla transformer should be nonreciprocal. This historical curiosity is mostly forgotten today, perhaps because it appears incorrect. However, Drude's prediction is shown to be correct for the conditions treated, demonstrating the importance of constraints in deriving equivalent circuits for distributed systems. The predicted nonreciprocity is not fundamental, but instead is an artifact of the misrepresentation of energy by an equivalent circuit. The application to modern equivalent circuits is discussed.

  8. Vantage TitanTM 3T 3-tesla MRI system with enhanced serviceability and comfort

    International Nuclear Information System (INIS)

    Kanazawa, Hitoshi; Okamoto, Kazuya; Yamamoto, Takao

    2011-01-01

    Since 3-tesla magnetic resonance imaging (MRI) systems appeared on the market, in addition to their clinical usefulness a variety of issues have been pointed out in the clinical setting. The 3-tesla MRI system has therefore gained a reputation as a difficult system suitable only for hospital facilities including university hospitals that specialize in medical research. To rectify this situation, Toshiba Medical Systems Corporation has developed the Vantage Titan TM 3T, which is expected to not only improve the MRI examination environment, but also to be applicable to patients with claustrophobia and those with large physiques for whom MRI examination has not been appropriate until now, while maintaining the clinical usefulness of the 3-tesla MRI system. The Vantage Titan 3T system also incorporates the Pianissimo TM noise reduction mechanism, which has already been introduced in our 1.5-tesla MRI system and has been highly evaluated by the market. This reduces the stress of patients by providing a quieter and more open examination environment compared with conventional MRI systems. (author)

  9. An energy upgrade from TESLA to a high-energy μ+μ- collider

    International Nuclear Information System (INIS)

    Neuffer, D.; Edwards, H.; Finley, D.

    1996-10-01

    We discuss the possible extension of a TESLA 250X250 GeV SRF e + e - linear collider to a multi-TeV μ + μ - collider, by future addition of a muon source, return arcs for recirculation and a collider ring. The TESLA SRF systems are potentially also suitable for multiturn acceleration of muon bunches, and could be adapted for use in a recirculating μ-linac. Many problems and design issues would need to be resolved, and further study is needed

  10. Local Multi-Channel RF Surface Coil versus Body RF Coil Transmission for Cardiac Magnetic Resonance at 3 Tesla: Which Configuration Is Winning the Game?

    Directory of Open Access Journals (Sweden)

    Oliver Weinberger

    Full Text Available The purpose of this study was to demonstrate the feasibility and efficiency of cardiac MR at 3 Tesla using local four-channel RF coil transmission and benchmark it against large volume body RF coil excitation.Electromagnetic field simulations are conducted to detail RF power deposition, transmission field uniformity and efficiency for local and body RF coil transmission. For both excitation regimes transmission field maps are acquired in a human torso phantom. For each transmission regime flip angle distributions and blood-myocardium contrast are examined in a volunteer study of 12 subjects. The feasibility of the local transceiver RF coil array for cardiac chamber quantification at 3 Tesla is demonstrated.Our simulations and experiments demonstrate that cardiac MR at 3 Tesla using four-channel surface RF coil transmission is competitive versus current clinical CMR practice of large volume body RF coil transmission. The efficiency advantage of the 4TX/4RX setup facilitates shorter repetition times governed by local SAR limits versus body RF coil transmission at whole-body SAR limit. No statistically significant difference was found for cardiac chamber quantification derived with body RF coil versus four-channel surface RF coil transmission. Our simulation also show that the body RF coil exceeds local SAR limits by a factor of ~2 when driven at maximum applicable input power to reach the whole-body SAR limit.Pursuing local surface RF coil arrays for transmission in cardiac MR is a conceptually appealing alternative to body RF coil transmission, especially for patients with implants.

  11. Local Multi-Channel RF Surface Coil versus Body RF Coil Transmission for Cardiac Magnetic Resonance at 3 Tesla: Which Configuration Is Winning the Game?

    Science.gov (United States)

    Winter, Lukas; Dieringer, Matthias A.; Els, Antje; Oezerdem, Celal; Rieger, Jan; Kuehne, Andre; Cassara, Antonino M.; Pfeiffer, Harald; Wetterling, Friedrich; Niendorf, Thoralf

    2016-01-01

    Introduction The purpose of this study was to demonstrate the feasibility and efficiency of cardiac MR at 3 Tesla using local four-channel RF coil transmission and benchmark it against large volume body RF coil excitation. Methods Electromagnetic field simulations are conducted to detail RF power deposition, transmission field uniformity and efficiency for local and body RF coil transmission. For both excitation regimes transmission field maps are acquired in a human torso phantom. For each transmission regime flip angle distributions and blood-myocardium contrast are examined in a volunteer study of 12 subjects. The feasibility of the local transceiver RF coil array for cardiac chamber quantification at 3 Tesla is demonstrated. Results Our simulations and experiments demonstrate that cardiac MR at 3 Tesla using four-channel surface RF coil transmission is competitive versus current clinical CMR practice of large volume body RF coil transmission. The efficiency advantage of the 4TX/4RX setup facilitates shorter repetition times governed by local SAR limits versus body RF coil transmission at whole-body SAR limit. No statistically significant difference was found for cardiac chamber quantification derived with body RF coil versus four-channel surface RF coil transmission. Our simulation also show that the body RF coil exceeds local SAR limits by a factor of ~2 when driven at maximum applicable input power to reach the whole-body SAR limit. Conclusion Pursuing local surface RF coil arrays for transmission in cardiac MR is a conceptually appealing alternative to body RF coil transmission, especially for patients with implants. PMID:27598923

  12. Local Multi-Channel RF Surface Coil versus Body RF Coil Transmission for Cardiac Magnetic Resonance at 3 Tesla: Which Configuration Is Winning the Game?

    Science.gov (United States)

    Weinberger, Oliver; Winter, Lukas; Dieringer, Matthias A; Els, Antje; Oezerdem, Celal; Rieger, Jan; Kuehne, Andre; Cassara, Antonino M; Pfeiffer, Harald; Wetterling, Friedrich; Niendorf, Thoralf

    2016-01-01

    The purpose of this study was to demonstrate the feasibility and efficiency of cardiac MR at 3 Tesla using local four-channel RF coil transmission and benchmark it against large volume body RF coil excitation. Electromagnetic field simulations are conducted to detail RF power deposition, transmission field uniformity and efficiency for local and body RF coil transmission. For both excitation regimes transmission field maps are acquired in a human torso phantom. For each transmission regime flip angle distributions and blood-myocardium contrast are examined in a volunteer study of 12 subjects. The feasibility of the local transceiver RF coil array for cardiac chamber quantification at 3 Tesla is demonstrated. Our simulations and experiments demonstrate that cardiac MR at 3 Tesla using four-channel surface RF coil transmission is competitive versus current clinical CMR practice of large volume body RF coil transmission. The efficiency advantage of the 4TX/4RX setup facilitates shorter repetition times governed by local SAR limits versus body RF coil transmission at whole-body SAR limit. No statistically significant difference was found for cardiac chamber quantification derived with body RF coil versus four-channel surface RF coil transmission. Our simulation also show that the body RF coil exceeds local SAR limits by a factor of ~2 when driven at maximum applicable input power to reach the whole-body SAR limit. Pursuing local surface RF coil arrays for transmission in cardiac MR is a conceptually appealing alternative to body RF coil transmission, especially for patients with implants.

  13. Local Multi-Channel RF Surface Coil versus Body RF Coil Transmission for Cardiac Magnetic Resonance at 3 Tesla: Which Configuration Is Winning the Game?

    OpenAIRE

    Weinberger, Oliver; Winter, Lukas; Dieringer, Matthias A.; Els, Antje; Oezerdem, Celal; Rieger, Jan; Kuehne, Andre; Cassara, Antonino M.; Pfeiffer, Harald; Wetterling, Friedrich; Niendorf, Thoralf

    2016-01-01

    INTRODUCTION: The purpose of this study was to demonstrate the feasibility and efficiency of cardiac MR at 3 Tesla using local four-channel RF coil transmission and benchmark it against large volume body RF coil excitation. METHODS: Electromagnetic field simulations are conducted to detail RF power deposition, transmission field uniformity and efficiency for local and body RF coil transmission. For both excitation regimes transmission field maps are acquired in a human torso phantom. For each...

  14. A compact multi-wire-layered secondary winding for Tesla transformer.

    Science.gov (United States)

    Zhao, Liang; Su, Jian-Cang; Li, Rui; Wu, Xiao-Long; Xu, Xiu-Dong; Qiu, Xu-Dong; Zeng, Bo; Cheng, Jie; Zhang, Yu; Gao, Peng-Cheng

    2017-05-01

    A compact multi-wire-layered (MWL) secondary winding for a Tesla transformer is put forward. The basic principle of this winding is to wind the metal wire on a polymeric base tube in a multi-layer manner. The tube is tapered and has high electrical strength and high mechanical strength. Concentric-circle grooves perpendicular to the axis of the tube are carved on the surface of the tube to wind the wire. The width of the groove is basically equal to the diameter of the wire so that the metal wire can be fixed in the groove without glue. The depth of the groove is n times of the diameter of the wire to realize the n-layer winding manner. All the concentric-circle grooves are connected via a spiral groove on the surface of the tube to let the wire go through. Compared with the traditional one-wire-layered (OWL) secondary winding for the Tesla transformer, the most conspicuous advantage of the MWL secondary winding is that the latter is compact with only a length of 2/n of the OWL. In addition, the MWL winding has the following advantages: high electrical strength since voids are precluded from the surface of the winding, high mechanical strength because polymer is used as the material of the base tube, and reliable fixation in the Tesla transformer as special mechanical connections are designed. A 2000-turn MWL secondary winding is fabricated with a winding layer of 3 and a total length of 1.0 m. Experiments to test the performance of this winding on a Tesla-type pulse generator are conducted. The results show that this winding can boost the voltage to 1 MV at a repetition rate of 50 Hz reliably for a lifetime longer than 10 4 pulses, which proves the feasibility of the MWL secondary winding.

  15. Quadrature Slotted Surface Coil Pair for Magnetic Resonance Imaging at 4 Tesla: Phantom Study

    Directory of Open Access Journals (Sweden)

    Solis S.E.

    2012-01-01

    Full Text Available A coil array was composed of two slotted surface coils forming a structure with two plates at 900, each one having 6 circular slots and is introduced in this paper. Numerical simulations of the magnetic field of this coil array were performed at 170 MHz using the finite element method to study its behaviour. This coil array was developed for brain magnetic resonance imaging to be operated at the resonant frequency of 170 MHz in the transceiver mode and quadrature driven. Numerical simulations demonstrated that electromagnetic interaction between the coil elements is negligible, and that the magnetic field showed a good uniformity. Phantom images were acquired with our coil array and standard pulse sequences on a research-dedicated 4 Tesla scanner. In vitro images showed the feasibility of this coil array for standard pulses and high field magnetic resonance imaging.

  16. Design study of 15-Tesla RHQT Nb3Al block type dipole magnet

    Energy Technology Data Exchange (ETDEWEB)

    Yamada, R.; Ambrosio, G.; Barzi, E.; Kashikin, V.; Kikuchi, A.; Novitski, I.; Takeuchi, T.; Wake, M.; Zlobin, A.; /Fermilab /NIMC, Tsukuba /KEK, Tsukuba

    2005-09-01

    The design study of the block type 15-Tesla RHQT Nb{sub 3}Al dipole magnet, and its merits over Nb{sub 3}Sn magnets are presented. The copper stabilized RHQT Nb{sub 3}Al strand is now becoming commercially available for the application to the accelerator magnets. A 1 mm diameter RHQT Nb{sub 3}Al strand with filament size about 50 {mu}, non-copper Jc about 1000 A/mm{sup 2} at 15 Tesla at 4.2K, copper ratio of 50%, can now be produced over several hundred meters. The stress and strain characteristics of the Nb{sub 3}Al strand are superior to the Nb{sub 3}Sn strand. Another advantage is that it can tolerate a longitudinal strain up to 0.55%. The RHQT Nb{sub 3}Al Rutherford cable will have less chance of contamination of the stabilizer, compared to Nb{sub 3}Sn cable. These characteristics of the RHQT Nb{sub 3}Al will be beneficial for designing and producing 15-Tesla dipole magnets. An example 15-Tesla magnet cross section, utilizing the RHQT Nb{sub 3}Sn strand is presented. A systematic investigation on RHQT Nb{sub 3}Al strands, its Rutherford cables, and building a small racetrack magnet for cable testing are proposed.

  17. Autism spectrum disorders in relation to parental occupation in technical fields.

    Science.gov (United States)

    Windham, Gayle C; Fessel, Karen; Grether, Judith K

    2009-08-01

    A previous study reported that fathers of children with autism spectrum disorders (ASD) were more likely to work as engineers, requiring "systemizing skills," and suggesting a distinct phenotype, but alternatively this may have been related to selection biases. We conducted a population-based study to explore whether fathers, or mothers, of children with ASD are over-represented in fields requiring highly technical skills. Subjects included 284 children with ASD and 659 gender-matched controls, born in 1994 in the San Francisco Bay Area. Parental occupation and industry were abstracted verbatim from birth certificates. Engineering, computer programming, and science were examined as highly technical occupations. To limit bias by parental socio-economic status, we selected a referent group of occupations that seemed professionally similar but of a less technical nature. Odds ratios (ORs) and 95% confidence intervals (CI) were calculated by logistic regression, adjusting for parental age, education, and child race. Mothers of cases were somewhat more likely to work in hi-tech occupations (6.7%) than mothers of controls (4.0%, P=0.07), but little difference was observed among fathers, nor for engineering separately. Compared to parents in other "white collar" occupations, the adjusted OR for highly technical occupations among mothers was 2.5 (95% CI: 1.2-5.3) and among fathers was 1.3 (95% CI: 0.79-2.1), with no evidence of a joint effect observed. Our results regarding maternal occupation in technical fields being associated with ASD in offspring suggest further study to distinguish parental occupation as a phenotypic marker of genetic loading vs. other social or exposure factors.

  18. Quantitative diffusion tensor MR imaging of the brain: field strength related variance of apparent diffusion coefficient (ADC) and fractional anisotropy (FA) scalars

    International Nuclear Information System (INIS)

    Huisman, Thierry A.G.M.; Loenneker, Thomas; Barta, Gerd; Bellemann, Matthias E.; Hennig, Juergen; Fischer, Joachim E.; Il'yasov, Kamil A.

    2006-01-01

    The objectives were to study the ''impact'' of the magnetic field strength on diffusion tensor imaging (DTI) metrics and also to determine whether magnetic-field-related differences in T2-relaxation times of brain tissue influence DTI measurements. DTI was performed on 12 healthy volunteers at 1.5 and 3.0 Tesla (within 2 h) using identical DTI scan parameters. Apparent diffusion coefficient (ADC) and fractional anisotropy (FA) values were measured at multiple gray and white matter locations. ADC and FA values were compared and analyzed for statistically significant differences. In addition, DTI measurements were performed at different echo times (TE) for both field strengths. ADC values for gray and white matter were statistically significantly lower at 3.0 Tesla compared with 1.5 Tesla (% change between -1.94% and -9.79%). FA values were statistically significantly higher at 3.0 Tesla compared with 1.5 Tesla (% change between +4.04 and 11.15%). ADC and FA values are not significantly different for TE=91 ms and TE=125 ms. Thus, ADC and FA values vary with the used field strength. Comparative clinical studies using ADC or FA values should consequently compare ADC or FA results with normative ADC or FA values that have been determined for the field strength used. (orig.)

  19. Note: A high-energy-density Tesla-type pulse generator with novel insulating oil

    Science.gov (United States)

    Liu, Sheng; Su, Jiancang; Fan, Xuliang

    2017-09-01

    A 10-GW high-energy-density Tesla-type pulse generator is developed with an improved insulating liquid based on a modified Tesla pulser—TPG700, of which the pulse forming line (PFL) is filled with novel insulating oil instead of transformer oil. Properties of insulating oil determining the stored energy density of the PFL are analyzed, and a criterion for appropriate oil is proposed. Midel 7131 is chosen as an application example. The results of insulating property experiment under tens-of-microsecond pulse charging demonstrate that the insulation capability of Midel 7131 is better than that of KI45X transformer oil. The application test in Tesla pulser TPG700 shows that the output power is increased to 10.5 GW with Midel 7131. The output energy density of TPG700 increases for about 60% with Midel 7131.

  20. Assessment of MRI issues at 3-Tesla for metallic surgical implants: findings applied to 61 additional skin closure staples and vessel ligation clips.

    Science.gov (United States)

    Gill, Amreeta; Shellock, Frank G

    2012-01-09

    Metallic skin closure staples and vessel ligation clips should be tested at 3-Tesla to characterize MRI issues in order to ensure patient safety. Therefore, metallic surgical implants were assessed at 3-Tesla for magnetic field interactions, MRI-related heating, and artifacts. A skin closure staple (Visistat Skin Stapler, staple, Polytetrafluoroethylene, PTFE, coated 316L/316LVM stainless steel; Teleflex Medical, Durham, NC) and a vessel ligation clip (Hemoclip Traditional, stainless steel; Teleflex Medical, Durham, NC) that represented the largest metallic sizes made from materials with the highest magnetic susceptibilities (i.e., based on material information) among 61 other surgical implants (52 metallic implants, 9 nonmetallic implants) underwent evaluation for magnetic field interactions, MRI-related heating, and artifacts using standardized techniques. MRI-related heating was assessed by placing each implant in a gelled-saline-filled phantom with MRI performed using a transmit/receive RF body coil at an MR system reported, whole body averaged SAR of 2.9-W/kg for 15-min. Artifacts were characterized using T1-weighted, SE and GRE pulse sequences. Each surgical implant showed minor magnetic field interactions (20- and 27-degrees, which is acceptable from a safety consideration). Heating was not substantial (highest temperature change, ≤ 1.6°C). Artifacts may create issues if the area of interest is in the same area or close to the respective surgical implant. The results demonstrated that it would be acceptable for patients with these metallic surgical implants to undergo MRI at 3-Tesla or less. Because of the materials and dimensions of the surgical implants that underwent testing, these findings pertain to 61 additional similar implants.

  1. Assessment of MRI issues at 3-Tesla for metallic surgical implants: findings applied to 61 additional skin closure staples and vessel ligation clips

    Directory of Open Access Journals (Sweden)

    Gill Amreeta

    2012-01-01

    Full Text Available Abstract Purpose Metallic skin closure staples and vessel ligation clips should be tested at 3-Tesla to characterize MRI issues in order to ensure patient safety. Therefore, metallic surgical implants were assessed at 3-Tesla for magnetic field interactions, MRI-related heating, and artifacts. Methods A skin closure staple (Visistat Skin Stapler, staple, Polytetrafluoroethylene, PTFE, coated 316L/316LVM stainless steel; Teleflex Medical, Durham, NC and a vessel ligation clip (Hemoclip Traditional, stainless steel; Teleflex Medical, Durham, NC that represented the largest metallic sizes made from materials with the highest magnetic susceptibilities (i.e., based on material information among 61 other surgical implants (52 metallic implants, 9 nonmetallic implants underwent evaluation for magnetic field interactions, MRI-related heating, and artifacts using standardized techniques. MRI-related heating was assessed by placing each implant in a gelled-saline-filled phantom with MRI performed using a transmit/receive RF body coil at an MR system reported, whole body averaged SAR of 2.9-W/kg for 15-min. Artifacts were characterized using T1-weighted, SE and GRE pulse sequences. Results Each surgical implant showed minor magnetic field interactions (20- and 27-degrees, which is acceptable from a safety consideration. Heating was not substantial (highest temperature change, ≤ 1.6°C. Artifacts may create issues if the area of interest is in the same area or close to the respective surgical implant. Conclusions The results demonstrated that it would be acceptable for patients with these metallic surgical implants to undergo MRI at 3-Tesla or less. Because of the materials and dimensions of the surgical implants that underwent testing, these findings pertain to 61 additional similar implants.

  2. Assessment of MRI issues at 3-Tesla for metallic surgical implants: findings applied to 61 additional skin closure staples and vessel ligation clips

    Science.gov (United States)

    2012-01-01

    Purpose Metallic skin closure staples and vessel ligation clips should be tested at 3-Tesla to characterize MRI issues in order to ensure patient safety. Therefore, metallic surgical implants were assessed at 3-Tesla for magnetic field interactions, MRI-related heating, and artifacts. Methods A skin closure staple (Visistat Skin Stapler, staple, Polytetrafluoroethylene, PTFE, coated 316L/316LVM stainless steel; Teleflex Medical, Durham, NC) and a vessel ligation clip (Hemoclip Traditional, stainless steel; Teleflex Medical, Durham, NC) that represented the largest metallic sizes made from materials with the highest magnetic susceptibilities (i.e., based on material information) among 61 other surgical implants (52 metallic implants, 9 nonmetallic implants) underwent evaluation for magnetic field interactions, MRI-related heating, and artifacts using standardized techniques. MRI-related heating was assessed by placing each implant in a gelled-saline-filled phantom with MRI performed using a transmit/receive RF body coil at an MR system reported, whole body averaged SAR of 2.9-W/kg for 15-min. Artifacts were characterized using T1-weighted, SE and GRE pulse sequences. Results Each surgical implant showed minor magnetic field interactions (20- and 27-degrees, which is acceptable from a safety consideration). Heating was not substantial (highest temperature change, ≤ 1.6°C). Artifacts may create issues if the area of interest is in the same area or close to the respective surgical implant. Conclusions The results demonstrated that it would be acceptable for patients with these metallic surgical implants to undergo MRI at 3-Tesla or less. Because of the materials and dimensions of the surgical implants that underwent testing, these findings pertain to 61 additional similar implants. PMID:22230200

  3. Hepatic Iron Quantification on 3 Tesla (3 T Magnetic Resonance (MR: Technical Challenges and Solutions

    Directory of Open Access Journals (Sweden)

    Muhammad Anwar

    2013-01-01

    Full Text Available MR has become a reliable and noninvasive method of hepatic iron quantification. Currently, most of the hepatic iron quantification is performed on 1.5 T MR, and the biopsy measurements have been paired with R2 and R2* values for 1.5 T MR. As the use of 3 T MR scanners is steadily increasing in clinical practice, it has become important to evaluate the practicality of calculating iron burden at 3 T MR. Hepatic iron quantification on 3 T MR requires a better understanding of the process and more stringent technical considerations. The purpose of this work is to focus on the technical challenges in establishing a relationship between T2* values at 1.5 T MR and 3 T MR for hepatic iron concentration (HIC and to develop an appropriately optimized MR protocol for the evaluation of T2* values in the liver at 3 T magnetic field strength. We studied 22 sickle cell patients using multiecho fast gradient-echo sequence (MFGRE 3 T MR and compared the results with serum ferritin and liver biopsy results. Our study showed that the quantification of hepatic iron on 3 T MRI in sickle cell disease patients correlates well with clinical blood test results and biopsy results. 3 T MR liver iron quantification based on MFGRE can be used for hepatic iron quantification in transfused patients.

  4. RHQT Nb3Al 15-Tesla magnet design study

    Energy Technology Data Exchange (ETDEWEB)

    Yamada, R.; Ambrosio, G.; Barzi, E.; Kashikin, V.; Kikuchi, A.; Novitski, I.; Takeuchi, T.; Wake, M.; Zlobin, A.; /Fermilab /NIMC, Tsukuba /KEK, Tsukuba

    2005-09-01

    Feasibility study of 15-Tesla dipole magnets wound with a new copper stabilized RHQT Nb{sub 3}Al Rutherford cable is presented. A new practical long copper stabilized RHQT Nb{sub 3}Al strand is presented, which is being developed and manufactured at the National Institute of Material Science (NIMS) in Japan. It has achieved a non-copper J{sub c} of 1000A/mm{sup 2} at 15 Tesla at 4.2K, with a copper over non-copper ratio of 1.04, and a filament size less than 50 microns. For this design study a short Rutherford cable with 28 Nb{sub 3}Al strands of 1 mm diameter will be fabricated late this year. The cosine theta magnet cross section is designed using ROXIE, and the stress and strain in the coil is estimated and studied with the characteristics of the Nb{sub 3}Al strand. The advantages and disadvantages of the Nb{sub 3}Al cable are compared with the prevailing Nb{sub 3}Sn cable from the point of view of stress-strain, J{sub c}, and possible degradation of stabilizer due to cabling. The Nb{sub 3}Al coil of the magnet, which will be made by wind and react method, has to be heat treated at 800 degree C for 10 hours. As preparation for the 15 Tesla magnet, a series of tests on strand and Rutherford cables are considered.

  5. Off Like a Rocket: A Media Discourse Analysis of Tesla Motor Corporation

    OpenAIRE

    McKay, Jordan

    2016-01-01

    Energy and transportation are topics of great importance to global sustainable development.  Tesla Motor Corporation is an electric vehicle company with the objective to “accelerate the world’s transition to sustainable energy” (Musk, 2016).  This thesis, a media discourse analysis, examines media texts concerning Tesla Motors to provide a better understanding of the company’s hitherto success in penetrating the automotive market.  Qualitative analyses of text were utilized to first define th...

  6. A test of a 2 Tesla superconducting transmission line magnet system

    International Nuclear Information System (INIS)

    Piekarz, Henryk; Carcagno, Ruben; Claypool, Brad; Foster, George W.; Hays, Steven L.; Huang, Yuenian; Kashikhin, Vladimir; Malamud, Ernest; Mazur, Peter O.; Nehring, Roger; Oleck, Andrew; Rabehl, Roger; Schlabach, Phil; Sylvester, Cosmore; Velev, Gueorgui; Volk, James; Wake, Masayoshi

    2005-01-01

    Superconducting transmission line magnet test system for an injector accelerator of a staged VLHC proton-proton colliding beam accelerator has been built and operated at Fermilab. The 1.5 m long, twin-aperture, combined function dipole magnet of 2 Tesla field is excited by a single turn 100 kA transmission line superconductor. The 100 kA dc current is generated using dc-dc switching converters powered by a bulk 240 kW supply. A pair of horizontally placed conventional leads facilitates transfer of this current to the magnet transmission line superconductor operating at liquid helium temperature. Fabrication of magnet components and magnet assembly work are described. The magnet test system and its operation are presented, and the performance is summarized

  7. A test of a 2 Tesla superconducting transmission line magnet system

    Energy Technology Data Exchange (ETDEWEB)

    Piekarz, Henryk; Carcagno, Ruben; Claypool, Brad; Foster, George W.; Hays, Steven L.; Huang, Yuenian; Kashikhin, Vladimir; Malamud, Ernest; Mazur, Peter O.; Nehring,; Oleck, Andrew; Rabehl, Roger; Schlabach, Phil; Sylvester, Cosmore; Velev, Gueorgui; Volk, James; /Fermilab; Wake, Masayoshi; /KEK, Tsukuba

    2005-09-01

    Superconducting transmission line magnet test system for an injector accelerator of a staged VLHC proton-proton colliding beam accelerator has been built and operated at Fermilab. The 1.5 m long, twin-aperture, combined function dipole magnet of 2 Tesla field is excited by a single turn 100 kA transmission line superconductor. The 100 kA dc current is generated using dc-dc switching converters powered by a bulk 240 kW supply. A pair of horizontally placed conventional leads facilitates transfer of this current to the magnet transmission line superconductor operating at liquid helium temperature. Fabrication of magnet components and magnet assembly work are described. The magnet test system and its operation are presented, and the performance is summarized.

  8. Survey of the technical-scientific research field in the Oslo district

    International Nuclear Information System (INIS)

    1975-12-01

    Organisations and institutes in the Oslo district which carry out research in the technical-scientific field are listed, with adress and telephone number. This includes a number of institutes whose activities are mainly or partly in the nuclear field. The list is subdivided into departments, with brief descriptions of their fields of activity, the scientific personnel with their special interests, and a detailed list of the special projects and activities of the departments. Special apparatus and equipment which the institutes have at their disposal are also mentioned with brief specifications. (JIW)

  9. Cavity digital control testing system by Simulink step operation method for TESLA linear accelerator and free electron laser

    Science.gov (United States)

    Czarski, Tomasz; Romaniuk, Ryszard S.; Pozniak, Krzysztof T.; Simrock, Stefan

    2004-07-01

    The cavity control system for the TESLA -- TeV-Energy Superconducting Linear Accelerator project is initially introduced in this paper. The FPGA -- Field Programmable Gate Array technology has been implemented for digital controller stabilizing cavity field gradient. The cavity SIMULINK model has been applied to test the hardware controller. The step operation method has been developed for testing the FPGA device coupled to the SIMULINK model of the analog real plant. The FPGA signal processing has been verified according to the required algorithm of the reference MATLAB controller. Some experimental results have been presented for different cavity operational conditions.

  10. Large scale Tesla coil guided discharges initiated by femtosecond laser filamentation in air

    Science.gov (United States)

    Arantchouk, L.; Point, G.; Brelet, Y.; Prade, B.; Carbonnel, J.; André, Y.-B.; Mysyrowicz, A.; Houard, A.

    2014-07-01

    The guiding of meter scale electric discharges produced in air by a Tesla coil is realized in laboratory using a focused terawatt laser pulse undergoing filamentation. The influence of the focus position, the laser arrival time, or the gap length is studied to determine the best conditions for efficient laser guiding. Discharge parameters such as delay, jitter, and resistance are characterized. An increase of the discharge length by a factor 5 has been achieved with the laser filaments, corresponding to a mean breakdown field of 2 kV/cm for a 1.8 m gap length. Consecutive guided discharges at a repetition rate of 10 Hz are also reported.

  11. Large-Signal Code TESLA: Current Status and Recent Development

    National Research Council Canada - National Science Library

    Chernyavskiy, Igor A; Vlasov, Alexander N; Cooke, Simon J; Abe, David K; Levush, Baruch; Antonsen, Jr., Thomas M; Nguyen, Khanh T

    2008-01-01

    .... One such tool is the large-signal code TESLA, which was successfully applied for the modeling of single-beam and multiple-beam klystron devices at the Naval Research Laboratory and which is now used by number of U.S. companies...

  12. Functional magnetic resonance imaging in a low-field intraoperative scanner.

    Science.gov (United States)

    Schulder, Michael; Azmi, Hooman; Biswal, Bharat

    2003-01-01

    Functional magnetic resonance imaging (fMRI) has been used for preoperative planning and intraoperative surgical navigation. However, most experience to date has been with preoperative images acquired on high-field echoplanar MRI units. We explored the feasibility of acquiring fMRI of the motor cortex with a dedicated low-field intraoperative MRI (iMRI). Five healthy volunteers were scanned with the 0.12-tesla PoleStar N-10 iMRI (Odin Medical Technologies, Israel). A finger-tapping motor paradigm was performed with sequential scans, acquired alternately at rest and during activity. In addition, scans were obtained during breath holding alternating with normal breathing. The same paradigms were repeated using a 3-tesla MRI (Siemens Corp., Allandale, N.J., USA). Statistical analysis was performed offline using cross-correlation and cluster techniques. Data were resampled using the 'jackknife' process. The location, number of activated voxels and degrees of statistical significance between the two scanners were compared. With both the 0.12- and 3-tesla imagers, motor cortex activation was seen in all subjects to a significance of p < 0.02 or greater. No clustered pixels were seen outside the sensorimotor cortex. The resampled correlation coefficients were normally distributed, with a mean of 0.56 for both the 0.12- and 3-tesla scanners (standard deviations 0.11 and 0.08, respectively). The breath holding paradigm confirmed that the expected diffuse activation was seen on 0.12- and 3-tesla scans. Accurate fMRI with a low-field iMRI is feasible. Such data could be acquired immediately before or even during surgery. This would increase the utility of iMRI and allow for updated intraoperative functional imaging, free of the limitations of brain shift. Copyright 2003 S. Karger AG, Basel

  13. Nikola Tesla - genije koji je premostio vekove

    Directory of Open Access Journals (Sweden)

    Vladimir T. Ristić

    2006-07-01

    Full Text Available Ispisujući prve stranice svoje obimne knjige o životnom putu Nikole Tesle, američki pisac Džon Oí Nil kaže: Tesla je bio mislilac i pronalazač najvišeg reda, onaj što mišljenjem, a ne slučajem, dolazi do otkrića, dok mu eksperiment služi samo za potvrdu njegove teze. On je bio i matematičar, znao je bezbroj formula napamet, tako da se najčešće nije morao služiti priručnicima; osim toga, imao je najsolidnije tehničko obrazovanje, što je, na primer, Edisonu nedostajalo. Nikola Tesla je osnovno školovanje započeo u rodnom Smiljanu, a nastavio i dovršio u Gospiću gde se sa roditeljima, posle smrti starijeg brata, preselio. Gimnaziju je upisao u Karlovcu. Bila je to ugledna škola, a u profesoru fizike Nikola je imao izuzetnog pedagoga, koji je svojim đacima umeo vrlo vešto da dočara čak i ono što je u fizici teško razumljivo.

  14. Large field-of-view transmission line resonator for high field MRI

    DEFF Research Database (Denmark)

    Zhurbenko, Vitaliy; Johannesson, Kristjan Sundgaard; Boer, Vincent

    2016-01-01

    Transmission line resonators is often a preferable choice for coils in high field magnetic resonance imaging (MRI), because they provide a number of advantages over traditional loop coils. The size of such resonators, however, is limited to shorter than half a wavelength due to high standing wave....... Achieved magnetic field distribution is compared to the conventional transmission line resonator. Imaging experiments are performed using 7 Tesla MRI system. The developed resonator is useful for building coils with large field-of-view....

  15. Aging and magnetism: Presenting a possible new holistic paradigm for ameliorating the aging process and the effects thereof, through externally applied physiologic PicoTesla magnetic fields.

    Science.gov (United States)

    Jacobson, Jerry; Sherlag, Benjamin

    2015-09-01

    A new holistic paradigm is proposed for slowing our genomic-based biological clocks (e.g. regulation of telomere length), and decreasing heat energy exigencies for maintenance of physiologic homeostasis. Aging is considered the result of a progressive slow burn in small volumes of tissues with increase in the quantum entropic states; producing desiccation, microscopic scarring, and disruption of cooperative coherent states. Based upon piezoelectricity, i.e. photon-phonon transductions, physiologic PicoTesla range magnetic fields may decrease the production of excessive heat energy through target specific, bio molecular resonant interactions, renormalization of intrinsic electromagnetic tissue profiles, and autonomic modulation. Prospectively, we hypothesize that deleterious effects of physical trauma, immunogenic microbiological agents, stress, and anxiety may be ameliorated. A particle-wave equation is cited to ascertain magnetic field parameters for application to the whole organism thereby achieving desired homeostasis; secondary to restoration of structure and function on quantum levels. We hypothesize that it is at the atomic level that physical events shape the flow of signals and the transmission of energy in bio molecular systems. References are made to experimental data indicating the aspecific efficacy of non-ionizing physiologic magnetic field profiles for treatment of various pathologic states. Copyright © 2015 Elsevier Ltd. All rights reserved.

  16. Soil moisture determination with Tesla NZK 203 neutron gage

    International Nuclear Information System (INIS)

    Hally, J.

    1977-01-01

    Soil moisture was measured using the NZK 203 neutron probe manufactured by Tesla Premysleni. The individual measuring sites were spaced at a distance of 100 m. The NZK 203 set consists of a NPK 202 moisture gage and a NSK 301 scintillation detector and features the following specifications: moisture density measuring range 20 to 500 kg/m 3 , 241 Am-Be fast neutron source having a neutron flux of 7.5x10 4 n.sec -1 +-10%, operating temperature -10 to +45 degC. The measured counting rate was primarily affected by the statistical fluctuation of ionizing radiation and by instrument instability. In order that these effects should be limited each measurement was repeated 10 times with the optimum measurement time at an interval of 20 to 100 sec. The NZK 203 Tesla set was proven to be suitable for rapid and reproducible determination of moisture profiles. (J.P.)

  17. Initial field measurements on the Chalk River superconducting cyclotron

    International Nuclear Information System (INIS)

    Ormrod, J.H.; Chan, K.C.; Hill, J.H.

    1980-12-01

    The midplane magnetic field of the Chalk River superconducting cyclotron has been mapped in detail over the full operating range of 2.5 to 5 tesla. The field measuring apparatus is described and results given include measurements of the field stability, reproducibility and harmonic content. (author)

  18. Navigating Community College Transfer in Science, Technical, Engineering, and Mathematics Fields

    Science.gov (United States)

    Packard, Becky Wai-Ling; Gagnon, Janelle L.; Senas, Arleen J.

    2012-01-01

    Given financial barriers facing community college students today, and workforce projections in science, technical, engineering, and math (STEM) fields, the costs of unnecessary delays while navigating transfer pathways are high. In this phenomenological study, we analyzed the delay experiences of 172 students (65% female) navigating community…

  19. Use of a 1.0 Tesla open scanner for evaluation of pediatric and congenital heart disease: a retrospective cohort study.

    Science.gov (United States)

    Lu, Jimmy C; Nielsen, James C; Morowitz, Layne; Musani, Muzammil; Ghadimi Mahani, Maryam; Agarwal, Prachi P; Ibrahim, El-Sayed H; Dorfman, Adam L

    2015-05-25

    Open cardiovascular magnetic resonance (CMR) scanners offer the potential for imaging patients with claustrophobia or large body size, but at a lower 1.0 Tesla magnetic field. This study aimed to evaluate the efficacy of open CMR for evaluation of pediatric and congenital heart disease. This retrospective, cross-sectional study included all patients ≤18 years old or with congenital heart disease who underwent CMR on an open 1.0 Tesla scanner at two centers from 2012-2014. Indications for CMR and clinical questions were extracted from the medical record. Studies were qualitatively graded for image quality and diagnostic utility. In a subset of 25 patients, signal-to-noise (SNR) and contrast-to-noise (CNR) ratios were compared to size- and diagnosis-matched patients with CMR on a 1.5 Tesla scanner. A total of 65 patients (median 17.3 years old, 60% male) were included. Congenital heart disease was present in 32 (50%), with tetralogy of Fallot and bicuspid aortic valve the most common diagnoses. Open CMR was used due to scheduling/equipment issues in 51 (80%), claustrophobia in 7 (11%), and patient size in 3 (5%); 4 patients with claustrophobia had failed CMR on a different scanner, but completed the study on open CMR without sedation. All patients had good or excellent image quality on black blood, phase contrast, magnetic resonance angiography, and late gadolinium enhancement imaging. There was below average image quality in 3/63 (5%) patients with cine images, and 4/15 (27%) patients with coronary artery imaging. SNR and CNR were decreased in cine and magnetic resonance angiography images compared to 1.5 Tesla. The clinical question was answered adequately in all but 2 patients; 1 patient with a Fontan had artifact from an embolization coil limiting RV volume analysis, and in 1 patient the right coronary artery origin was not well seen. Open 1.0 Tesla scanners can effectively evaluate pediatric and congenital heart disease, including patients with claustrophobia

  20. Optimization of materials for the parts that compose a Tesla turbine

    International Nuclear Information System (INIS)

    Rocha, Geovana Vilas Boas da; Guimaraes, Lamartine N.F.; Placco, Guilherme M.

    2013-01-01

    The TERRA project (Tecnologia de Reatores Rapidos Avancados) of the Aeronautica (Brazil) aims to develop the necessary technologies for the design of nuclear microreactors. These, in turn, aim to address the thermal and electrical needs in space vehicles. One of the activities of this project is to build a closed thermal cycle, the Rankine type in order to test a Tesla turbine type developed by the group. In this thermodynamic cycle the water is transformed into steam, which triggers a turbine which, in turn, provide power to the alternator to be converted into electricity. The work presented a survey of the materials available on the national market for machining a Tesla type turbine. The surveys were made considering the characteristics and operating conditions of a specific thermal cycle, the interest of the group. Results: cost-benefit tables for each party of the turbine, characteristics of each material, the machining process, as well as a comparison between one of 304L stainless steel model turbine with a turbine with the selected materials. The results from this study raised the level of sophistication of the research involved the TERRA project, since the study of ideal materials that make up the parts of a Tesla type turbine in a heat cycle is unprecedented

  1. Impact of magnetic fields on the response behaviour of an uranium-scintillator-calorimeter

    International Nuclear Information System (INIS)

    Mainusch, J.

    1990-10-01

    For an examination of the signals of the ZEUS calorimeter, an uranium-scintillator calorimeter has been built in cooperation with Toronto University in Canada. This calorimeter very largely corresponds to an HAC1 section of the ZEUS calorimeter. The measurements in the magnetic field were done perpendicular to the incoming beam at field strengths of 0.01 Tesla up to 1.4 Tesla, with electrons of 1-6 GeV. In addition, the magnetic field impact on the signal of the uranium radioactivity was measured. An LED signal was used to check and verify sufficient shielding of the photo tubes against magnetic field effects. It was possible to keep amplification changes to less than 0.1%. (orig./DG) [de

  2. Exposure to magnetic fields of railway engine drivers: A case study in Italy

    International Nuclear Information System (INIS)

    Contessa, G. M.; Falsaperla, R.; Brugaletta, V.; Rossi, P.

    2010-01-01

    A case study of exposure assessment of railway workers to static and extremely low frequency (ELF) magnetic fields is presented. A measurement campaign was conducted in aboard Italian main line trains. All measurements were performed on board during regular service (two engine drivers were simultaneously present), in all places potentially accessible to personnel, considering routes ranging from a few tens of kilometres to hundreds of kilometres. The measurement protocol was mostly based on broadband metres and personal metres were employed to assess individual exposure. Surveys on static and ELF magnetic fields were performed for seven different models of engine or electrified train. Traction motors were fed by alternating current (AC) current, except for two engines, where AC current fed only auxiliary services. The final result is that the average exposure to static magnetic field was a little higher than the background geomagnetic field; occasionally in few areas it could reach levels of the order of milli-tesla. The average exposure to ELF magnetic fields was in the order of 1-2 μT, with higher levels (few micro-tesla) only for one engine; occasionally in hot spots, close to wiring or specific equipment, the field values could reach several tens of micro-tesla. (authors)

  3. High-resolution, in vivo magnetic resonance imaging of Drosophila at 18.8 Tesla.

    Directory of Open Access Journals (Sweden)

    Brian Null

    Full Text Available High resolution MRI of live Drosophila was performed at 18.8 Tesla, with a field of view less than 5 mm, and administration of manganese or gadolinium-based contrast agents. This study demonstrates the feasibility of MR methods for imaging the fruit fly Drosophila with an NMR spectrometer, at a resolution relevant for undertaking future studies of the Drosophila brain and other organs. The fruit fly has long been a principal model organism for elucidating biology and disease, but without capabilities like those of MRI. This feasibility marks progress toward the development of new in vivo research approaches in Drosophila without the requirement for light transparency or destructive assays.

  4. First cold test of TESLA superconducting RF cavity in horizontal cryostat (CHECHIA)

    International Nuclear Information System (INIS)

    Kuzminski, J.

    1996-01-01

    In the framework of the TESLA project, the horizontal cryostat (CHECHIA) was built to test a superconducting RF cavity equipped with its helium vessel, magnetic shielding, cold tuner, main coupler and higher order modes couplers under realistic conditions before final assembly of eight cavities into TESLA Test Facility cryo-module. The results of the first cold tests in CHECHIA, performed at DESY with a 9-cell cavity (C19) to be used in the TTF injector are presented. Additional measurements of mechanical stability under RF operation (frequency variation with He pressure, Lorentz detuning) and cryogenic and electric measurements of power dissipation are presented. (author)

  5. Simulations of the Static Tuning for the TESLA Linear Collider

    CERN Document Server

    Schulte, Daniel

    2003-01-01

    At the heart of the TESLA linear collider are the two 10 km long superconducting linacs. A linac is constructed from 858 cryomodules each containing 12 nine-cell 1.3 GHz superconducting cavities. 355 quadrupoles provide the necessary beam focusing. The advantages of low-frequency superconducting RF in terms of wakefield behaviour are well known, and the TESLA alignment tolerances are relatively loose. However, the effects of cavity tilts and their impact of the linac beam-based alignment algorithms have until recently not been fully investigated. In addition, the strong sensitivity to correlated emittance growth due to the high beam-beam disruption parameter makes it desirable to control the linac emittance down to a few percent. In this report we discuss various static tuning algorithms and present new simulation results. Discussions of the relative merits and applicability of the methods is also discussed.

  6. Performance of TESLA Cavities After Fabrication and Preparation in Industry

    CERN Document Server

    Pekeler, Michael; Bauer, Stefan; Knobloch, Jens; Vom Stein, Peter

    2005-01-01

    In order to demonstrate cw operation of TESLA cavities in linear accelerators driving FEL applications, two TESLA cavities were manufactured and prepared by ACCEL for BESSY. After production, both cavities were prepared for vertical test at ACCEL's premises using state of the art chemical polishing and high pressure water rinsing techniques. The cavities were tested in DESY's vertical RF test installation. Accelerating gradients close to 25 MV/m were reached. One cavity was completed with a helium vessel modified for cw operation and prepared with chemical polishing, high pressure water rinsing, and assembled with the required High Power Coupler at ACCEL. The fully dressed cavity was then shipped under vacuum to BESSY and tested in the horizontal cryostat HoBiCaT. Horizontal RF test results will be presented and compared with the vertical test results.

  7. MR-guided discography using an open 1 Tesla MRI system

    International Nuclear Information System (INIS)

    Streitparth, Florian; Bucourt, M. de; Hamm, B.; Teichgraeber, U.; Hartwig, T.; Strube, P.; Putzier, M.; Schnackenburg, B.; Chopra, S.

    2011-01-01

    To evaluate the feasibility of MR-guided discography using an open 1 Tesla MRI system. 48 disc segments of 41 patients scheduled for intradiscal thermal treatment, total disc replacement or spondylodesis were examined. A 1.0-T open MRI was used for instrument guidance and imaging. After primary disc puncture under guidance of interactive PDw TSE imaging, 1-2 ml of gadolinium contrast saline mixture was injected into the disc. The occurrence of memory pain during injection was recorded. Axial and sagittal T1w TSE images with and without fat saturation were obtained. All MRI discograms were analysed by two readers, who were blinded to the clinical findings. Overall, the placement of the puncture needle in the targeted disc was accurate under real-time MR guidance. Injections were technically successful in all cases. No major complications occurred. The mean procedure time was 17 min (range 13-34 min). Image quality of contrast-enhanced MR discograms was excellent when using an optimized gadolinium contrast saline mixture of 1:600. Memory pain was detected in 16 out of 48 affected segments. MR-guided discography is accurate and safe. Multiplanar dynamic imaging facilitates the puncture of discs and provides high-quality MR discograms. (orig.)

  8. Tesla-VUPJT instruments suitable for application in water management

    International Nuclear Information System (INIS)

    Novakova, O.; Broj, K.; Fronka, O.; Kula, J.; Slezak, V.

    1987-01-01

    A comparison is made of new instruments by Tesla, Czechoslovakia, viz. the NA 6201 for low alpha and beta counting and the NRR 610 alpha-beta automatic gauge, with similar foreign made instruments. The factors are discussed which affect the overall detection efficiency and the background level. (B.S.). 4 tabs

  9. Superconducting superstructure for the TESLA collider

    Energy Technology Data Exchange (ETDEWEB)

    Sekutowicz, J.; Tang, C. [DESY, MHF-SL, Hamburg (Germany); Ferrario, M. [INFN, Laboratori Nazionali di Frascati, Rome (Italy)

    1998-04-01

    The Authors discuss the new layout of a cavity chain (superstructure) allowing, the Authors hope, significant cost reduction of the RF system of both linacs of the TESLA linear collider. The proposed scheme increases the fill factor and thus makes an effective gradient of an accelerator higher. The authors present mainly computations that have performed up to now and which encouraged to order the copper model of the scheme, still keeping in mind that experiments with a beam will be necessary to prove if the proposed solution can be used for the acceleration.

  10. Hip imaging of avascular necrosis at 7 Tesla compared with 3 Tesla

    International Nuclear Information System (INIS)

    Theysohn, J.M.; Kraff, O.; Theysohn, N.; Orzada, S.; Lauenstein, T.C.; Landgraeber, S.; Ladd, M.E.

    2014-01-01

    To compare ultra-high field, high-resolution bilateral magnetic resonance imaging (MRI) of the hips at 7 Tesla (T) with 3 T MRI in patients with avascular necrosis (AVN) of the femoral head by subjective image evaluations, contrast measurements, and evaluation of the appearance of imaging abnormalities. Thirteen subjects with avascular necrosis treated using advanced core decompression underwent MRI at both 7 T and 3 T. Sequence parameters as well as resolution were kept identical for both field strengths. All MR images (MEDIC, DESS, PD/T2w TSE, T1w TSE, and STIR) were evaluated by two radiologists with regard to subjective image quality, soft tissue contrasts, B1 homogeneity (four-point scale, higher values indicating better image quality) and depiction of imaging abnormalities of the femoral heads (three-point scale, higher values indicating the superiority of 7 T). Contrast ratios of soft tissues were calculated and compared with subjective data. 7-T imaging of the femoral joints, as well as 3-T imaging, achieved ''good'' to ''very good'' quality in all sequences. 7 T showed significantly higher soft tissue contrasts for T2w and MEDIC compared with 3 T (cartilage/fluid: 2.9 vs 2.2 and 3.6 vs 2.6), better detailed resolution for cartilage defects (PDw, T2w, T1w, MEDIC, DESS > 2.5) and better visibility of joint effusions (MEDIC 2.6; PDw/T2w 2.4; DESS 2.2). Image homogeneity compared with 3 T (3.9-4.0 for all sequences) was degraded, especially in TSE sequences at 7 T through signal variations (7 T: 2.1-2.9); to a lesser extent also GRE sequences (7 T: 2.9-3.5). Imaging findings related to untreated or treated AVN were better delineated at 3 T (≤1.8), while joint effusions (2.2-2.6) and cartilage defects (2.5-3.0) were better visualized at 7 T. STIR performed much more poorly at 7 T, generating large contrast variations (1.5). 7-T hip MRI showed comparable results in hip joint imaging compared with 3 T with slight advantages in contrast detail (cartilage defects

  11. Beyond 100 Tesla: Scientific experiments using single-turn coils

    Science.gov (United States)

    Portugall, Oliver; Solane, Pierre Yves; Plochocka, Paulina; Maude, Duncan K.; Nicholas, Robin J.

    2013-01-01

    Current opportunities and recent examples for research in magnetic fields well above 100 T using single-turn coils are discussed. After a general introduction into basic principles and technical constraints associated with the generation of Megagauss fields we discuss data obtained at the LNCMI Toulouse, where such fields are routinely used for scientific applications.

  12. Two-Slotted Surface Coil Array for Magnetic Resonance Imaging at 4 Tesla

    International Nuclear Information System (INIS)

    Solis, S. E.; Hernandez, J. A.; Rodriguez, A. O.; Tomasi, D.

    2008-01-01

    Arrays of antennas have been widely accepted for magnetic resonance imaging applications due to their high signal-to-noise ratio (SNR) over large volumes of interest. A new surface coil based on the magnetron tube and called slotted surface coil, has been recently introduced by our group. This coil design experimentally demonstrated a significant improvement over the circular-shaped coil when used in the receive-only mode. The slotted coils formed a two-sheet structure with a 90 deg. separation and each coil had 6 circular slots. Numerical simulations were performed using the finite element method for this coil design to study the behaviour of the array magnetic field. Then, we developed a two-coil array for brain magnetic resonance imaging to be operated at the resonant frequency of 170 MHz in the transceiver mode. Phantom images were acquired with our coil array and standard pulse sequences on a research-dedicated 4 Tesla scanner. Numerical simulations demonstrated that electromagnetic interaction between the coil elements is negligible, and that the magnetic field showed a good uniformity. In vitro images showed the feasibility of this coil array for standard pulses for high field magnetic resonance imaging

  13. Report From the International Linear Collider Technical Review Committee

    International Nuclear Information System (INIS)

    Loew, Gregory A.

    2003-01-01

    The International Linear Collider Technical Review Committee (ILC-TRC), formed in 1994, was reconvened in February 2001 by the International Committee for Future Accelerators (ICFA) to assess the current technical status of all electron-positron linear collider designs at hand in the world: TESLA, JLC-C, JLC-X/NLC and CLIC. The ILC-TRC worked for exactly two years and submitted its report to ICFA in February 2003. This paper presents the motivation behind the study, the charge to the committee and its organization, a table of machine parameters for 500 GeV c.m. energy and later upgrades to higher energies, the methodology used to assess the designs, and a ranked list of R and D tasks still deemed necessary between now and the time any one of the projects is selected by the HEP community and begins construction. Possible future developments are briefly discussed

  14. Comparison of Pelvic Phased-Array versus Endorectal Coil Magnetic Resonance Imaging at 3 Tesla for Local Staging of Prostate Cancer

    OpenAIRE

    Kim, Bum Soo; Kim, Tae-Hwan; Kwon, Tae Gyun; Yoo, Eun Sang

    2012-01-01

    Purpose Several studies have demonstrated the superiority of endorectal coil magnetic resonance imaging (MRI) over pelvic phased-array coil MRI at 1.5 Tesla for local staging of prostate cancer. However, few have studied which evaluation is more accurate at 3 Tesla MRI. In this study, we compared the accuracy of local staging of prostate cancer using pelvic phased-array coil or endorectal coil MRI at 3 Tesla. Materials and Methods Between January 2005 and May 2010, 151 patients underwent radi...

  15. In vivo functional connectome of human brainstem nuclei of the ascending arousal, autonomic, and motor systems by high spatial resolution 7-Tesla fMRI.

    Science.gov (United States)

    Bianciardi, Marta; Toschi, Nicola; Eichner, Cornelius; Polimeni, Jonathan R; Setsompop, Kawin; Brown, Emery N; Hämäläinen, Matti S; Rosen, Bruce R; Wald, Lawrence L

    2016-06-01

    Our aim was to map the in vivo human functional connectivity of several brainstem nuclei with the rest of the brain by using seed-based correlation of ultra-high magnetic field functional magnetic resonance imaging (fMRI) data. We used the recently developed template of 11 brainstem nuclei derived from multi-contrast structural MRI at 7 Tesla as seed regions to determine their connectivity to the rest of the brain. To achieve this, we used the increased contrast-to-noise ratio of 7-Tesla fMRI compared with 3 Tesla and time-efficient simultaneous multi-slice imaging to cover the brain with high spatial resolution (1.1-mm isotropic nominal resolution) while maintaining a short repetition time (2.5 s). The delineated Pearson's correlation-based functional connectivity diagrams (connectomes) of 11 brainstem nuclei of the ascending arousal, motor, and autonomic systems from 12 controls are presented and discussed in the context of existing histology and animal work. Considering that the investigated brainstem nuclei play a crucial role in several vital functions, the delineated preliminary connectomes might prove useful for future in vivo research and clinical studies of human brainstem function and pathology, including disorders of consciousness, sleep disorders, autonomic disorders, Parkinson's disease, and other motor disorders.

  16. Interaction mechanisms and biological effects of static magnetic fields

    Energy Technology Data Exchange (ETDEWEB)

    Tenforde, T.S.

    1994-06-01

    Mechanisms through which static magnetic fields interact with living systems are described and illustrated by selected experimental observations. These mechanisms include electrodynamic interactions with moving, ionic charges (blood flow and nerve impulse conduction), magnetomechanical interactions (orientation and translation of molecules structures and magnetic particles), and interactions with electronic spin states in charge transfer reactions (photo-induced electron transfer in photosynthesis). A general summary is also presented of the biological effects of static magnetic fields. There is convincing experimental evidence for magnetoreception mechanisms in several classes of lower organisms, including bacteria and marine organisms. However, in more highly evolved species of animals, there is no evidence that the interactions of static magnetic fields with flux densities up to 2 Tesla (1 Tesla [T] = 10{sup 4} Gauss) produce either behavioral or physiolocical alterations. These results, based on controlled studies with laboratory animals, are consistent with the outcome of recent epidemiological surveys on human populations exposed occupationally to static magnetic fields.

  17. Impact of magnetic field strength and receiver coil in ocular MRI: a phantom and patient study.

    Science.gov (United States)

    Erb-Eigner, K; Warmuth, C; Taupitz, M; Willerding, G; Bertelmann, E; Asbach, P

    2013-09-01

    Generally, high-resolution MRI of the eye is performed with small loop surface coils. The purpose of this phantom and patient study was to investigate the influence of magnetic field strength and receiver coils on image quality in ocular MRI. The eyeball and the complex geometry of the facial bone were simulated by a skull phantom with swine eyes. MR images were acquired with two small loop surface coils with diameters of 4 cm and 7 cm and with a multi-channel head coil at 1.5 and 3 Tesla, respectively. Furthermore, MRI of the eye was performed prospectively in 20 patients at 1.5 Tesla (7 cm loop surface coil) and 3 Tesla (head coil). These images were analysed qualitatively and quantitatively and statistical significance was tested using the Wilcoxon-signed-rank test (a p-value of less than 0.05 was considered to indicate statistical significance). The analysis of the phantom images yielded the highest mean signal-to-noise ratio (SNR) at 3 Tesla with the use of the 4 cm loop surface coil. In the phantom experiment as well as in the patient studies the SNR was higher at 1.5 Tesla by applying the 7 cm surface coil than at 3 Tesla by applying the head coil. Concerning the delineation of anatomic structures no statistically significant differences were found. Our results show that the influence of small loop surface coils on image quality (expressed in SNR) in ocular MRI is higher than the influence of the magnetic field strength. The similar visibility of detailed anatomy leads to the conclusion that the image quality of ocular MRI at 3 Tesla remains acceptable by applying the head coil as a receiver coil. © Georg Thieme Verlag KG Stuttgart · New York.

  18. Dynamic multi-coil technique (DYNAMITE) shimming for echo-planar imaging of the human brain at 7 Tesla.

    Science.gov (United States)

    Juchem, Christoph; Umesh Rudrapatna, S; Nixon, Terence W; de Graaf, Robin A

    2015-01-15

    Gradient-echo echo-planar imaging (EPI) is the primary method of choice in functional MRI and other methods relying on fast MRI to image brain activation and connectivity. However, the high susceptibility of EPI towards B0 magnetic field inhomogeneity poses serious challenges. Conventional magnetic field shimming with low-order spherical harmonic (SH) functions is capable of compensating shallow field distortions, but performs poorly for global brain shimming or on specific areas with strong susceptibility-induced B0 distortions such as the prefrontal cortex (PFC). Excellent B0 homogeneity has been demonstrated recently in the human brain at 7 Tesla with the DYNAmic Multi-coIl TEchnique (DYNAMITE) for magnetic field shimming (J Magn Reson (2011) 212:280-288). Here, we report the benefits of DYNAMITE shimming for multi-slice EPI and T2* mapping. A standard deviation of 13Hz was achieved for the residual B0 distribution in the human brain at 7 Tesla with DYNAMITE shimming and was 60% lower compared to conventional shimming that employs static zero through third order SH shapes. The residual field inhomogeneity with SH shimming led to an average 8mm shift at acquisition parameters commonly used for fMRI and was reduced to 1.5-3mm with DYNAMITE shimming. T2* values obtained from the prefrontal and temporal cortices with DYNAMITE shimming were 10-50% longer than those measured with SH shimming. The reduction of the confounding macroscopic B0 field gradients with DYNAMITE shimming thereby promises improved access to the relevant microscopic T2* effects. The combination of high spatial resolution and DYNAMITE shimming allows largely artifact-free EPI and T2* mapping throughout the brain, including prefrontal and temporal lobe areas. DYNAMITE shimming is expected to critically benefit a wide range of MRI applications that rely on excellent B0 magnetic field conditions including EPI-based fMRI to study various cognitive processes and assessing large-scale brain connectivity

  19. Dynamic Multi-Coil Technique (DYNAMITE) Shimming for Echo-Planar Imaging of the Human Brain at 7 Tesla

    Science.gov (United States)

    Juchem, Christoph; Rudrapatna, S. Umesh; Nixon, Terence W.; de Graaf, Robin A.

    2014-01-01

    Gradient-echo echo-planar imaging (EPI) is the primary method of choice in functional MRI and other methods relying on fast MRI to image brain activation and connectivity. However, the high susceptibility of EPI towards B0 magnetic field inhomogeneity poses serious challenges. Conventional magnetic field shimming with low-order spherical harmonic (SH) functions is capable of compensating shallow field distortions, but performs poorly for global brain shimming or on specific areas with strong susceptibility-induced B0 distortions such as the prefrontal cortex (PFC). Excellent B0 homogeneity has been demonstrated recently in the human brain at 7 Tesla with the DYNAmic Multi-coIl TEchnique (DYNAMITE) for magnetic field shimming (Juchem et al., J Magn Reson (2011) 212:280-288). Here, we report the benefits of DYNAMITE shimming for multi-slice EPI and T2* mapping. A standard deviation of 13 Hz was achieved for the residual B0 distribution in the human brain at 7 Tesla with DYNAMITE shimming and was 60% lower compared to conventional shimming that employs static zero through third order SH shapes. The residual field inhomogeneity with SH shimming led to an average 8 mm shift at acquisition parameters commonly used for fMRI and was reduced to 1.5-3 mm with DYNAMITE shimming. T2* values obtained from the prefrontal and temporal cortices with DYNAMITE shimming were 10-50% longer than those measured with SH shimming. The reduction of the confounding macroscopic B0 field gradients with DYNAMITE shimming thereby promises improved access to the relevant microscopic T2* effects. The combination of high spatial resolution and DYNAMITE shimming allows largely artifact-free EPI and T2* mapping throughout the brain, including prefrontal and temporal lobe areas. DYNAMITE shimming is expected to critically benefit a wide range of MRI applications that rely on excellent B0 magnetic field conditions including EPI-based fMRI to study various cognitive processes and assessing large

  20. Field convergence between technical writers and technical translators

    DEFF Research Database (Denmark)

    Gnecchi, M.; Maylath, B.; Mousten, Birthe

    2011-01-01

    As translation of technical documents continues to grow rapidly and translation becomes more automated, the roles of professional communicators and translators appear to be converging. This paper updates preliminary findings first presented at the 2008 International Professional Communication...

  1. Reproducibility of small animal cine and scar cardiac magnetic resonance imaging using a clinical 3.0 tesla system

    International Nuclear Information System (INIS)

    Manka, Robert; Jahnke, Cosima; Hucko, Thomas; Dietrich, Thore; Gebker, Rolf; Schnackenburg, Bernhard; Graf, Kristof; Paetsch, Ingo

    2013-01-01

    To evaluate the inter-study, inter-reader and intra-reader reproducibility of cardiac cine and scar imaging in rats using a clinical 3.0 Tesla magnetic resonance (MR) system. Thirty-three adult rats (Sprague–Dawley) were imaged 24 hours after surgical occlusion of the left anterior descending coronary artery using a 3.0 Tesla clinical MR scanner (Philips Healthcare, Best, The Netherlands) equipped with a dedicated 70 mm solenoid receive-only coil. Left-ventricular (LV) volumes, mass, ejection fraction and amount of myocardial scar tissue were measured. Intra-and inter-observer reproducibility was assessed in all animals. In addition, repeat MR exams were performed in 6 randomly chosen rats within 24 hours to assess inter-study reproducibility. The MR imaging protocol was successfully completed in 32 (97%) animals. Bland-Altman analysis demonstrated high intra-reader reproducibility (mean bias%: LV end-diastolic volume (LVEDV), -1.7%; LV end-systolic volume (LVESV), -2.2%; LV ejection fraction (LVEF), 1.0%; LV mass, -2.7%; and scar mass, -1.2%) and high inter-reader reproducibility (mean bias%: LVEDV, 3.3%; LVESV, 6.2%; LVEF, -4.8%; LV mass, -1.9%; and scar mass, -1.8%). In addition, a high inter-study reproducibility was found (mean bias%: LVEDV, 0.1%; LVESV, -1.8%; LVEF, 1.0%; LV mass, -4.6%; and scar mass, -6.2%). Cardiac MR imaging of rats yielded highly reproducible measurements of cardiac volumes/function and myocardial infarct size on a clinical 3.0 Tesla MR scanner system. Consequently, more widely available high field clinical MR scanners can be employed for small animal imaging of the heart e.g. when aiming at serial assessments during therapeutic intervention studies

  2. Feasibility study of Nb3Al Rutherford cable for high field accelerator magnet application

    Energy Technology Data Exchange (ETDEWEB)

    Yamada, R.; /Fermilab; Kikuchi, A.; /Tsukuba Magnet Lab.; Ambrosio, G.; Andreev, N.; Barzi, E.; Cooper, C.; Feher, S.; Kashikhin, V.V.; Lamm, M.; Novitski, I.; /Fermilab; Takeuchi, T.; /Tsukuba Magnet Lab.; Tartaglia, M.; Turrioni, D.; /Fermilab; Verweij, A.P.; /CERN; Wake, M.; Willering, G; /Tsukuba Magnet Lab.; Zlobin, A.V.; /Fermilab

    2006-08-01

    Feasibility study of Cu stabilized Nb{sub 3}Al strand and Rutherford cable for the application to high field accelerator magnets are being done at Fermilab in collaboration with NIMS. The Nb{sub 3}Al strand, which was developed and manufactured at NIMS in Japan, has a non-copper Jc of about 844 A/mm{sup 2} at 15 Tesla at 4.2 K, a copper content of 50%, and filament size of about 50 microns. Rutherford cables with 27 Nb{sub 3}Al strands of 1.03 mm diameter were fabricated and tested. Quench tests on a short cable were done to study its stability with only its self field, utilizing a high current transformer. A pair of 2 meter long Nb{sub 3}Al cables was tested extensively at CERN at 4.3 and 1.9 K up to 11 Tesla including its self field with a high transport current of 20.2 kA. In the low field test we observed instability near splices and in the central region. This is related to the flux-jump like behavior, because of excessive amount of Nb in the Nb{sub 3}Al strand. There is possibility that the Nb in Nb{sub 3}Al can cause instability below 2 Tesla field regions. We need further investigation on this problem. Above 8 Tesla, we observed quenches near the critical surface at fast ramp rate from 1000 to 3000 A/sec, with quench velocity over 100 m/sec. A small racetrack magnet was made using a 14 m of Rutherford cable and successfully tested up to 21.8 kA, corresponding to 8.7 T.

  3. Conventional 20-TeV, 10-Tesla, p/sup +-/ colliders

    International Nuclear Information System (INIS)

    Diebold, R.; Ankenbrandt, C.; Collins, T.

    1982-01-01

    The performance of various 20-TeV colliders is discussed assuming 10-Tesla bending magnets. For bunched beams, the luminosity for anti pp collisions will be approximately x 10 31 cm - 2 sec - 1 where is the average number of interactions per bunch collision desired by the experimenters; for pp collisions this becomes x 10 32 cm - 2 sec - 1 . Values of up to 25 can be accommodated in a straightforward manner. Continuous beam pp collisions may yield a luminosity of 10 33 to 10 34 cm - 2 sec - 1 if the large amount of energy in the intense beams can be handled. Assuming that adequate and reliable 10-Tesla magnets can be built without unforeseen difficulties, the construction cost of such a collider, together with its new laboratory in the desert, would cost 2 to 3 billion dollars (FY-82 dollars) using present-day, conventional techniques. Although such a machine appears straightforward to build, considerable R and D will be required in order to optimize the design and bring down costs

  4. Characterization of a prototype MR-compatible Delta4 QA system in a 1.5 tesla MR-linac

    Science.gov (United States)

    de Vries, J. H. W.; Seravalli, E.; Houweling, A. C.; Woodings, S. J.; van Rooij, R.; Wolthaus, J. W. H.; Lagendijk, J. J. W.; Raaymakers, B. W.

    2018-01-01

    To perform patient plan quality assurance (QA) on a newly installed MR-linac (MRL) it is necessary to have an MR-compatible QA device. An MR compatible device (MR-Delta4) has been developed together with Scandidos AB (Uppsala, Sweden). The basic characteristics of the detector response, such as short-term reproducibility, dose linearity, field size dependency, dose rate dependency, dose-per-pulse dependency and angular dependency, were investigated for the clinical Delta4-PT as well as for the MR compatible version. All tests were performed with both devices on a conventional linac and the MR compatible device was tested on the MRL as well. No statistically significant differences were found in the short-term reproducibility (tesla magnetic field of the Elekta MR-linac

  5. Strategic Alliance with Competitors in the Electric Vehicle Market: Tesla Motor’s Case

    Directory of Open Access Journals (Sweden)

    Taesu Cheong

    2016-01-01

    Full Text Available We investigate how the choice of coopetition of the simultaneous pursuit of collaboration and competition dynamically impacts both the participating firms and also the other self-developing ones in the same market. A conceptual framework of mathematical models obtained from the arguments and insights in the literature is used to undertake an in-depth study through a multiperiod analysis from 2013 to 2020 of an exemplar case of coopetition, the two concurrently ongoing coopetition partnerships in the US electric vehicle (EV market, the Tesla Motors-Daimler AG alliance and the Tesla Motors-Toyota alliance and the other firms which are not involved in coopetition.

  6. An 8-GW long-pulse generator based on Tesla transformer and pulse forming network.

    Science.gov (United States)

    Su, Jiancang; Zhang, Xibo; Li, Rui; Zhao, Liang; Sun, Xu; Wang, Limin; Zeng, Bo; Cheng, Jie; Wang, Ying; Peng, Jianchang; Song, Xiaoxin

    2014-06-01

    A long-pulse generator TPG700L based on a Tesla transformer and a series pulse forming network (PFN) is constructed to generate intense electron beams for the purpose of high power microwave (HPM) generation. The TPG700L mainly consists of a 12-stage PFN, a built-in Tesla transformer in a pulse forming line, a three-electrode gas switch, a transmission line with a trigger, and a load. The Tesla transformer and the compact PFN are the key technologies for the development of the TPG700L. This generator can output electrical pulses with a width as long as 200 ns at a level of 8 GW and a repetition rate of 50 Hz. When used to drive a relative backward wave oscillator for HPM generation, the electrical pulse width is about 100 ns on a voltage level of 520 kV. Factors affecting the pulse waveform of the TPG700L are also discussed. At present, the TPG700L performs well for long-pulse HPM generation in our laboratory.

  7. An 8-GW long-pulse generator based on Tesla transformer and pulse forming network

    Energy Technology Data Exchange (ETDEWEB)

    Su, Jiancang; Zhang, Xibo; Li, Rui; Zhao, Liang, E-mail: zhaoliang0526@163.com; Sun, Xu; Wang, Limin; Zeng, Bo; Cheng, Jie; Wang, Ying; Peng, Jianchang; Song, Xiaoxin [Science and Technology on High Power Microwave Laboratory, Northwest Institute of Nuclear Technology, Xi' an, Shaanxi 710024 (China)

    2014-06-15

    A long-pulse generator TPG700L based on a Tesla transformer and a series pulse forming network (PFN) is constructed to generate intense electron beams for the purpose of high power microwave (HPM) generation. The TPG700L mainly consists of a 12-stage PFN, a built-in Tesla transformer in a pulse forming line, a three-electrode gas switch, a transmission line with a trigger, and a load. The Tesla transformer and the compact PFN are the key technologies for the development of the TPG700L. This generator can output electrical pulses with a width as long as 200 ns at a level of 8 GW and a repetition rate of 50 Hz. When used to drive a relative backward wave oscillator for HPM generation, the electrical pulse width is about 100 ns on a voltage level of 520 kV. Factors affecting the pulse waveform of the TPG700L are also discussed. At present, the TPG700L performs well for long-pulse HPM generation in our laboratory.

  8. ATLAS Barrel Toroid magnet reached nominal field

    CERN Multimedia

    2006-01-01

     On 9 November the barrel toroid magnet reached its nominal field of 4 teslas, with an electrical current of 21 000 amperes (21 kA) passing through the eight superconducting coils as shown on this graph

  9. TECHNICAL COORDINATION

    CERN Multimedia

    A. Ball

    Although the incident on 19th September brought an untimely, temporary close to the exciting and successful commissioning of CMS with beam, activity at point 5 resumed with barely reduced intensity once underground access was restored. The preliminary steps were to re-fill the beamipe to atmospheric pressure with pure neon gas, to de-classify the cavern for radiological risks and to get agreement for formally deferring screening and tracing of material extracted from UXC. As planned, attention was then focused on completing commissioning of the solenoid, whose progression towards nominal 3.8 Tesla operating field had been interrupted a few shifts from its conclusion. Additional mechanical restraints and shielding structures needed to be installed to control the effects of field escaping from the return yoke and finding other pathways between the magnet poles. Certain pumps, sensors, lights and cameras, absent during the extensive “MTCC” surface testing in 2006, needed to be protected, w...

  10. Pill-Box Cavity BPM For TESLA Cryomodul

    CERN Document Server

    Sargsyan, V

    2003-01-01

    A new cavity BPM with 10 μm resolution is designed and fabricated to perform single bunch measurements at the TESLA linear collider. In order to have a low energy dissipation in the cryogenic supermodule, the inner surface of the cavity is copper plated. Cross-talk is minimised by a special polarisation design. The electronics, at 1.5 GHz, is a homodyne receiver normalised to the bunch charge. Its LO-signal for down-conversion is taken from the same cavity.

  11. In vivo sensitivity estimation and imaging acceleration with rotating RF coil arrays at 7 Tesla

    Science.gov (United States)

    Li, Mingyan; Jin, Jin; Zuo, Zhentao; Liu, Feng; Trakic, Adnan; Weber, Ewald; Zhuo, Yan; Xue, Rong; Crozier, Stuart

    2015-03-01

    Using a new rotating SENSitivity Encoding (rotating-SENSE) algorithm, we have successfully demonstrated that the rotating radiofrequency coil array (RRFCA) was capable of achieving a significant reduction in scan time and a uniform image reconstruction for a homogeneous phantom at 7 Tesla. However, at 7 Tesla the in vivo sensitivity profiles (B1-) become distinct at various angular positions. Therefore, sensitivity maps at other angular positions cannot be obtained by numerically rotating the acquired ones. In this work, a novel sensitivity estimation method for the RRFCA was developed and validated with human brain imaging. This method employed a library database and registration techniques to estimate coil sensitivity at an arbitrary angular position. The estimated sensitivity maps were then compared to the acquired sensitivity maps. The results indicate that the proposed method is capable of accurately estimating both magnitude and phase of sensitivity at an arbitrary angular position, which enables us to employ the rotating-SENSE algorithm to accelerate acquisition and reconstruct image. Compared to a stationary coil array with the same number of coil elements, the RRFCA was able to reconstruct images with better quality at a high reduction factor. It is hoped that the proposed rotation-dependent sensitivity estimation algorithm and the acceleration ability of the RRFCA will be particularly useful for ultra high field MRI.

  12. In vivo sensitivity estimation and imaging acceleration with rotating RF coil arrays at 7 Tesla.

    Science.gov (United States)

    Li, Mingyan; Jin, Jin; Zuo, Zhentao; Liu, Feng; Trakic, Adnan; Weber, Ewald; Zhuo, Yan; Xue, Rong; Crozier, Stuart

    2015-03-01

    Using a new rotating SENSitivity Encoding (rotating-SENSE) algorithm, we have successfully demonstrated that the rotating radiofrequency coil array (RRFCA) was capable of achieving a significant reduction in scan time and a uniform image reconstruction for a homogeneous phantom at 7 Tesla. However, at 7 Tesla the in vivo sensitivity profiles (B1(-)) become distinct at various angular positions. Therefore, sensitivity maps at other angular positions cannot be obtained by numerically rotating the acquired ones. In this work, a novel sensitivity estimation method for the RRFCA was developed and validated with human brain imaging. This method employed a library database and registration techniques to estimate coil sensitivity at an arbitrary angular position. The estimated sensitivity maps were then compared to the acquired sensitivity maps. The results indicate that the proposed method is capable of accurately estimating both magnitude and phase of sensitivity at an arbitrary angular position, which enables us to employ the rotating-SENSE algorithm to accelerate acquisition and reconstruct image. Compared to a stationary coil array with the same number of coil elements, the RRFCA was able to reconstruct images with better quality at a high reduction factor. It is hoped that the proposed rotation-dependent sensitivity estimation algorithm and the acceleration ability of the RRFCA will be particularly useful for ultra high field MRI. Copyright © 2014 Elsevier Inc. All rights reserved.

  13. Excerpts from Prodigal Genius: The Life of Nikola Tesla

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 12; Issue 3. Excerpts from Prodigal Genius: The Life of Nikola Tesla. John J O Neill. Classics Volume 12 Issue 3 March 2007 pp 91-96. Fulltext. Click here to view fulltext PDF. Permanent link: https://www.ias.ac.in/article/fulltext/reso/012/03/0091-0096 ...

  14. Assessing the MR compatibility of dental retainer wires at 7 Tesla.

    Science.gov (United States)

    Wezel, Joep; Kooij, Bert Jan; Webb, Andrew G

    2014-10-01

    To determine the MR compatibility of common dental retainer wires at 7 Tesla in terms of potential RF heating and magnetic susceptibility effects. Electromagnetic simulations and experimental results were compared for dental retainer wires placed in tissue-mimicking phantoms. Simulations were then performed for a human model with wire in place. Finally, image quality was assessed for different scanning protocols and wires. Simulations and experimental data in phantoms agreed well, with the length of the wire correlating to maximum heating in phantoms being approximately 47 mm. Even in this case, no substantial heating occurs when scanning within the specific absorption rate (SAR) guidelines for the head. Image distortions from the most ferromagnetic dental wire were not significant for any brain region. Dental retainer wires appear to be MR compatible at 7 Tesla. Copyright © 2013 Wiley Periodicals, Inc.

  15. Natural radioactivity of coal and fly ash at the Nikola Tesla B TPP

    Directory of Open Access Journals (Sweden)

    Kisić Dragica M.

    2013-01-01

    Full Text Available Serbian thermal power plants (TPPs produce siliceous fly ash from lignite in the quantity of approximately 6 million tons per year. The potential market for the use of fly ash is operational, but for the time being, only used by cement producers. Fly ash radioactivity could be one of the major points of concern when larger use of fly ash is planned, particularly in the Serbian construction industry. Radioactivity measurements have been conducted regularly for decades. This paper presents the results of a ten-year fly ash radioactivity measurements at the Nikola Tesla B TPP located in Obrenovac. In addition, the paper compares the natural radionuclides coal content data combusted by the Nikola Tesla B TPP boilers coming from the Kolubara Basin and ash created during coal combustion. Fly ash created in the Nikola Tesla TPPs boilers is characterised by the increased concentration of the natural radionuclides content compared to coal. This is the so-called technologically enhanced natural radioactivity (Technologically Enhanced Occurring Radioactive Material - TENORM of industrial waste, whereas the average specific activities: 232Th in coal amount to 25.2 Bq/kg, and in fly ash and coal 84.2 Bq/kg and 238U 38.3 Bq/kg, respectively. Following the obtained natural radionuclides content results it may be concluded that the Nikola Tesla B TPP ash may be disposed into the environment. Ash may be used also in the construction industry (civil engineering. In building construction applications, ash share as the additive to other building materials depends from its physical and chemical characteristics, as well as from the radionuclides activity: 266Ra, 232Th and 40K. Unlike the thermal power plants regularly (once a year testing the specific natural radionuclides activity in the combusted coal and boiler fly ash, Electric Power Industry of Serbia has not performed large-scale investigations of the natural radionuclides content in coal within the Kolubara

  16. Technical procedures for utilities and solid waste: Environmental Field Program, Deaf Smith County site, Texas: Final draft

    International Nuclear Information System (INIS)

    1987-08-01

    The evaluation of environmental issues and concerns and the addressing of statutory requirements are fundamental parts in the characterization of the site in Deaf Smith County, Texas for the US Department of Energy's Salt Repository Project (SRP). To ensure that the environmental field program comprehensively addresses the issues and requirements of the project, a site study plan (SSP) has been prepared for Utilities and Solid Waste considerations. This technical procedure (TP) has been developed to implement the field program described in the Utilities and Solid Waste Site Study Plan. The purpose and scope of the Utilities and Solid Waste Technical Procedure is to develop and implement a data collection procedure to fulfill the data base needs of the Utilities and Solid Waste SSP. The procedure describes a method of obtaining, assessing and verifying the capabilities of the regional service utilities and disposal contractors. This data base can be used to identify a preferred service source for the engineering contractor. The technical procedure was produced under the guidelines established in Technical Administrative Procedure No. 1.0, Preparation, Review and Approval of Technical Procedures

  17. 4 Tesla Whole Body MRI MRSI System for Investigation of Neurodegenerative Diseases

    National Research Council Canada - National Science Library

    Weiner, Michael W

    2004-01-01

    The overall long-term goal of imaging research to be performed with this 4 Tesla Siemens/Bruker MRI system is the development of improved diagnostic methods for accurate detection of neurodegenerative...

  18. Anaestesimonitorering ved magnetisk resonans undersøgelser

    DEFF Research Database (Denmark)

    Garde, K; Sørensen, M B; Boelt, P

    1992-01-01

    render possible investigation of unconscious or anaesthetized patients in scanners with magnetic fields of over 1.5 Tesla. The medical technical difficulties involved are mentioned and the solutions which are employed in the Danish scientific Centre for Magnetic Resonance in Hvidovre Hospital...

  19. La cellule d'essais du LHC fonctionne avec succès pendant 24h

    CERN Multimedia

    CERN Press Office. Geneva

    1994-01-01

    On 6 and 7 December a string of powerful superconducting magnets for CERN's next particle accelerator the Large Hadron Collider (LHC) ran successfully at 8.36 Tesla for 24 hours. 8.36 Tesla is the magnetic field required to accelerate protons to the required energy for LHC and this result demonstrates that the key technical choices made for the construction of the LHC magnets were correct. The test magnets have shown that they can operate reliably under the same working conditions as the future accelerator.

  20. Test measurement of a new TESLA cavity beam position monitor at the ELBE linac

    International Nuclear Information System (INIS)

    Sargsyan, V.; Schreiber, H.J.; Evtushenko, P.; Schurig, R.

    2004-01-01

    A new type of a cavity BPM proposed for beam position determination along the TESLA linac was tested at the accelerator ELBE in Rossendorf / Dresden. Measurements using an improved BPM (large and stable cross-talk isolation, significantly less energy dissipation, a novel LO signal generation) were performed in single- and multi-bunch regimes. Agreement with expectations was found. The low bunch charge available allowed for preliminary measurements on sensitivity and position resolution, which extrapolated to TESLA would ful l the demands for precise bunch-to-bunch position determination. Possible improvements, in particular on the signal processing scheme, are also discussed. (orig.)

  1. Diffusion tensor imaging of the normal prostate at 3 Tesla

    International Nuclear Information System (INIS)

    Guerses, Bengi; Kabakci, Neslihan; Kovanlikaya, Arzu; Firat, Zeynep; Bayram, Ali; Kovanlikaya, Ilhami; Ulud, Aziz M.

    2008-01-01

    The aim of this study was to assess the feasibility of diffusion tensor imaging (DTI) of the prostate and to determine normative fractional anisotropy (FA) and apparent diffusion coefficient (ADC) values of healthy prostate with a 3-Tesla magnetic resonance imaging (MRI) system. Thirty volunteers with a mean age of 28 (25-35) years were scanned with a 3-Tesla MRI (Intera Achieva; Philips, The Netherlands) system using a six-channel phased array coil. Initially, T2-weighted turbo spin-echo (TSE) axial images of the prostate were obtained. In two subjects, a millimetric hypointense signal change was detected in the peripheral zones on T2-weighted TSE images. These two subjects were excluded from the study. DTI with single-shot echo-planar imaging (ssEPI) was performed in the remaining 28 subjects. ADC and FA values were measured using the manufacturer supplied software by positioning 9-pixel ROIs on each zone. Differences between parameters of the central and peripheral zones were assessed. Mean ADC value of the central (1.220 ± 0.271 x 10 -3 mm 2 /s) was found to be significantly lower when compared with the peripheral gland (1.610 ± 0.347 x 10 -3 mm 2 /s) (P < 0.01). Mean FA of the central gland was significantly higher (0.26), compared with the peripheral gland (0.16) (P < 0.01). This study shows the feasibility of prostate DTI with a 3-Tesla MR system and the normative FA and ADC values of peripheral and central zones of the normal prostate. The results are compatible with the microstructural organization of the gland. (orig.)

  2. Transport properties of Cu-doped bismuth selenide single crystals at high magnetic fields up to 60 Tesla: Shubnikov-de Haas oscillations and π-Berry phase

    Science.gov (United States)

    Romanova, Taisiia A.; Knyazev, Dmitry A.; Wang, Zhaosheng; Sadakov, Andrey V.; Prudkoglyad, Valery A.

    2018-05-01

    We report Shubnikov-de Haas (SdH) and Hall oscillations in Cu-doped high quality bismuth selenide single crystals. To increase the accuracy of Berry phase determination by means of the of the SdH oscillations phase analysis we present a study of n-type samples with bulk carrier density n ∼1019 -1020cm-3 at high magnetic field up to 60 Tesla. In particular, Landau level fan diagram starting from the value of the Landau index N = 4 was plotted. Thus, from our data we found π-Berry phase that directly indicates the Dirac nature of the carriers in three-dimensional topological insulator (3D TI) based on Cu-doped bismuth selenide. We argued that in our samples the magnetotransport is determined by a general group of carriers that exhibit quasi-two-dimensional (2D) behaviour and are characterized by topological π-Berry phase. Along with the main contribution to the conductivity the presence of a small group of bulk carriers was registered. For 3D-pocket Berry phase was identified as zero, which is a characteristic of trivial metallic states.

  3. Large-Signal Code TESLA: Improvements in the Implementation and in the Model

    National Research Council Canada - National Science Library

    Chernyavskiy, Igor A; Vlasov, Alexander N; Anderson, Jr., Thomas M; Cooke, Simon J; Levush, Baruch; Nguyen, Khanh T

    2006-01-01

    We describe the latest improvements made in the large-signal code TESLA, which include transformation of the code to a Fortran-90/95 version with dynamical memory allocation and extension of the model...

  4. Start-to-end simulations of SASE FEL at the TESLA Test Facility

    International Nuclear Information System (INIS)

    Dohlus, M.; Floettmann, K.; Limberg, T.; Saldin, E.L; Schneidmiller, E.A.; Kozlov, O.S.; Yurkov, M.V.; Piot, Ph.

    2004-01-01

    VUV SASE FEL at the TESLA Test Facility (Phase 1) was successfully running and reached saturation in the wavelength range 80-120 nm. We present a posteriori start-to-end simulations of this machine. The codes Astra and elegant are used to track particle distribution from the cathode to the undulator entrance. An independent simulation of the beam dynamics in the bunch compressor is performed with the code CSRtrack. SASE FEL process is simulated with the code FAST. The simulation results are in good agreement with the measured properties of SASE FEL radiation. It is shown that the beam dynamics after the bunch compressor is mainly defined by space charge fields. FEL radiation is produced by the head of the electron bunch having a peak current of about 3 kA and a duration of 100 fs

  5. Usefulness of 3-Tesla cardiac magnetic resonance imaging in the assessment of aortic stenosis severity in routine clinical practice.

    Science.gov (United States)

    Levy, Franck; Iacuzio, Laura; Civaia, Filippo; Rusek, Stephane; Dommerc, Carine; Hugues, Nicolas; Alexandrescu, Clara; Dor, Vincent; Tribouilloy, Christophe; Dreyfus, Gilles

    2016-11-01

    Recently, 1.5-Tesla cardiac magnetic resonance imaging (CMR) was reported to provide a reliable alternative to transthoracic echocardiography (TTE) for the quantification of aortic stenosis (AS) severity. Few data are available using higher magnetic field strength MRI systems in this context. To evaluate the feasibility and reproducibility of the assessment of aortic valve area (AVA) using 3-Tesla CMR in routine clinical practice, and to assess concordance between TTE and CMR for the estimation of AS severity. Ninety-one consecutive patients (60 men; mean age 74±10years) with known AS documented by TTE were included prospectively in the study. All patients underwent comprehensive TTE and CMR examination, including AVA estimation using the TTE continuity equation (0.81±0.18cm 2 ), direct CMR planimetry (CMRp) (0.90±0.22cm 2 ) and CMR using Hakki's formula (CMRhk), a simplified Gorlin formula (0.70±0.19cm 2 ). Although significant agreement with TTE was found for CMRp (r=0.72) and CMRhk (r=0.66), CMRp slightly overestimated (bias=0.11±0.18cm 2 ) and CMRhk slightly underestimated (bias=-0.11±0.17cm 2 ) AVA compared with TTE. Inter- and intraobserver reproducibilities of CMR measurements were excellent (r=0.72 and r=0.74 for CMRp and r=0.88 and r=0.92 for peak aortic velocity, respectively). 3-Tesla CMR is a feasible, radiation-free, reproducible imaging modality for the estimation of severity of AS in routine practice, knowing that CMRp tends to overestimate AVA and CMRhk to underestimate AVA compared with TTE. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  6. Business Model Design: Lessons Learned from Tesla Motors

    OpenAIRE

    Chen , Yurong; Perez , Yannick

    2015-01-01

    International audience; Electric vehicle (EV) industry is still in the introduction stage in product life cycle, and dominant design remains unclear. EV companies, both incumbent from the car industry and new comers, have long taken numerous endeavors to promote EV in the niche market by providing innovative products and business models. While most carmakers still take 'business as usual' approach for developing their EV production and offers, Tesla Motors, an EV entrepreneurial firm, stands ...

  7. Parallel computation of electrostatic potentials and fields in technical geometries on SUPRENUM

    International Nuclear Information System (INIS)

    Alef, M.

    1990-02-01

    The programs EPOTZR und EFLDZR have been developed in order to compute electrostatic potentials and the corresponding fields in technical geometries (example: Diode geometry for optimum focussing of ion beams in pulsed high-current ion diodes). The Poisson equation is discretized in a two-dimensional boundary-fitted grid in the (r,z)-plane and solved using multigrid methods. The z- and r-components of the field are determined by numerical differentiation of the potential. This report contains the user's guide of the SUPRENUM versions EPOTZR-P and EFLDZR-P. (orig./HP) [de

  8. High-resolution MRI of the wrist and finger joints in patients with rheumatoid arthritis: comparison of 1.5 Tesla and 3.0 Tesla

    International Nuclear Information System (INIS)

    Wieners, Gero; Detert, Jacqueline; Burmester, Gerd; Backhaus, Marina; Streitparth, Florian; Fischbach, Frank; Bruhn, Harald; Pech, Maciej; Ricke, Jens

    2007-01-01

    The goal of this study was to compare magnetic resonance (MR) image quality at different field strengths for evaluating lesions in wrist and finger joints of patients with rheumatoid arthritis (RA) in order to determine whether the higher field strength provides diagnostic gain. The hand mainly affected in 17 RA patients was examined at 1.5 Tesla (T) and 3.0 T with comparable MR imaging (MRI) protocols. MR images were reviewed twice by two experienced radiologists using the Rheumatoid Arthritis MRI Scoring System (RAMRIS) of the OMERACT (Outcome Measures in Rheumatoid Arthritis Clinical Trials) group. Image quality was rated on a five-point scale using Friedmann's test and Kendall's W-test for statistical analysis. Image comparison revealed better image quality at higher field strength. Image quality of T1-weighted images was rated 14-22% better at 3.0 T compared with 1.5 T by both readers. Moreover, the rating for the T2-weighted-images acquired at 3.0 T was one point better in the five-point scale used. Inter-reader correlation for image quality, bone erosions/defects, edema and synovitis ranged between 0.6 and 0.9 at 3.0 T and between 0.6 and 0.8 at 1.5 T. Intra-reader correlation for these parameters was high at 0.8-1.0. MRI image quality of RA hands is superior at 3.0 T, while an acceptable image quality is achieved at 1.5 T, which improves the evaluation of extent of bone edema, synovitis and identification of small bone erosions. (orig.)

  9. Hippocampal disconnection in early Alzheimer's disease: a 7 tesla MRI study

    NARCIS (Netherlands)

    Wisse, L.E.; Reijmer, Y.D.; Telgte, A. ter; Kuijf, H.J.; Leemans, A.; Luijten, P.R.; Koek, H.L.; Geerlings, M.I.; Biessels, G.J.

    2015-01-01

    BACKGROUND: In patients with Alzheimer's disease (AD), atrophy of the entorhinal cortex (ERC) and hippocampal formation may induce degeneration of connecting white matter tracts. OBJECTIVE: We examined the association of hippocampal subfield and ERC atrophy at 7 tesla MRI with fornix and

  10. Cortical Cerebral Microinfarcts on 3 Tesla MRI in Patients with Vascular Cognitive Impairment.

    Science.gov (United States)

    Ferro, Doeschka A; van Veluw, Susanne J; Koek, Huiberdina L; Exalto, Lieza G; Biessels, Geert Jan

    2017-01-01

    Cerebral microinfarcts (CMIs) are small ischemic lesions that are a common neuropathological finding in patients with stroke or dementia. CMIs in the cortex can now be detected in vivo on 3 Tesla MRI. To determine the occurrence of CMIs and associated clinical features in patients with possible vascular cognitive impairment (VCI). 182 memory-clinic patients (mean age 71.4±10.6, 55% male) with vascular injury on brain MRI (i.e., possible VCI) underwent a standardized work-up including 3 Tesla MRI and cognitive assessment. A control group consisted of 70 cognitively normal subjects (mean age 70.6±4.7, 60% male). Cortical CMIs and other neuroimaging markers of vascular brain injury were rated according to established criteria. Occurrence of CMIs was higher (20%) in patients compared to controls (10%). Among patients, the presence of CMIs was associated with male sex, history of stroke, infarcts, and white matter hyperintensities. CMI presence was also associated with a diagnosis of vascular dementia and reduced performance in multiple cognitive domains. CMIs on 3 Tesla MRI are common in patients with possible VCI and co-occur with imaging markers of small and large vessel disease, likely reflecting a heterogeneous etiology. CMIs are associated with worse cognitive performance, independent of other markers of vascular brain injury.

  11. A semi-automated algorithm for hypothalamus volumetry in 3 Tesla magnetic resonance images.

    Science.gov (United States)

    Wolff, Julia; Schindler, Stephanie; Lucas, Christian; Binninger, Anne-Sophie; Weinrich, Luise; Schreiber, Jan; Hegerl, Ulrich; Möller, Harald E; Leitzke, Marco; Geyer, Stefan; Schönknecht, Peter

    2018-07-30

    The hypothalamus, a small diencephalic gray matter structure, is part of the limbic system. Volumetric changes of this structure occur in psychiatric diseases, therefore there is increasing interest in precise volumetry. Based on our detailed volumetry algorithm for 7 Tesla magnetic resonance imaging (MRI), we developed a method for 3 Tesla MRI, adopting anatomical landmarks and work in triplanar view. We overlaid T1-weighted MR images with gray matter-tissue probability maps to combine anatomical information with tissue class segmentation. Then, we outlined regions of interest (ROIs) that covered potential hypothalamus voxels. Within these ROIs, seed growing technique helped define the hypothalamic volume using gray matter probabilities from the tissue probability maps. This yielded a semi-automated method with short processing times of 20-40 min per hypothalamus. In the MRIs of ten subjects, reliabilities were determined as intraclass correlations (ICC) and volume overlaps in percent. Three raters achieved very good intra-rater reliabilities (ICC 0.82-0.97) and good inter-rater reliabilities (ICC 0.78 and 0.82). Overlaps of intra- and inter-rater runs were very good (≥ 89.7%). We present a fast, semi-automated method for in vivo hypothalamus volumetry in 3 Tesla MRI. Copyright © 2018 Elsevier B.V. All rights reserved.

  12. RF Phase Reference Distribution System for the TESLA Technology Based Projects

    CERN Document Server

    Czuba, K; Romaniuk, R S

    2013-01-01

    Since many decades physicists have been building particle accelerators and usually new projects became more advanced, more complicated and larger than predecessors. The importance and complexity of the phase reference distribution systems used in these accelerators have grown significantly during recent years. Amongst the most advanced of currently developed accelerators are projects based on the TESLA technology. These projects require synchronization of many RF devices with accuracy reaching femtosecond levels over kilometre distances. Design of a phase reference distribution system fulfilling such requirements is a challenging scientific task. There are many interdisciplinary problems which must be solved during the system design. Many, usually negligible issues, may became very important in such system. Furthermore, the design of a distribution system on a scale required for the TESLA technology based projects is a new challenge and there is almost no literature sufficiently covering this subject. This th...

  13. BI-ground microstrip array coil vs. conventional microstrip array coil for mouse imaging at 7 tesla

    Science.gov (United States)

    Hernández, Ricardo; Terrones, M. A. López; Jakob, P. M.

    2012-10-01

    At high field strengths, the need for more efficient high frequency coils has grown. Since the radiation losses and the interaction between coil and sample increase proportionally to field strength, the quality factor (Q) and the sensitivity of the coil decrease as consequence of these negative effects. Since Zhang et al proposed in 2001 a new surface coil based on the microstrip transmission line for high frequency, different Tx-Rx phased arrays based on this concept have been already introduced in animal and whole body systems at high field strengths, each of them with different modifications in order to get better field homogeneity, SNR or isolation between coil elements in the array. All these arrays for animals systems have been built for rat imaging. One of these modifications is called BI-Ground Microstrip Array Coil (BIGMAC). The implementation of a smaller two-channel BIGMAC design for mouse imaging is studied and its performance compared to a two-channel conventional Microstrip array at 7 Tesla, the higher isolation by using BIGMAC elements in comparison with conventional Microstrip elements is shown in this work.

  14. A Novel X-ray Diffractometer for the Florida Split Coil 25 Tesla Magnet

    Science.gov (United States)

    Wang, Shengyu; Kovalev, Alexey; Suslov, Alexey; Siegrist, Theo

    2014-03-01

    At National High Magnetic Field Laboratory (NHMFL), we are developing a unique X-ray diffractometer for the 25 Tesla Florida Split Coil Magnet for scattering experiments under extremely high static magnetic fields. The X-ray source is a sealed tube (copper or molybdenum anode), connected to the magnet by an evacuated beam tunnel. The detectors are either an image plate or a silicon drift detector, with the data acquisition system based on LabVIEW. Our preliminary experimental results showed that the performance of the detector electronics and the X-ray generator is reliable in the fringe magnetic fields produced at the highest field of 25 T. Using this diffractometer, we will make measurements on standard samples, such as LaB6, Al2O3 and Si, to calibrate the diffraction system. Magnetic samples, such as single crystal HoMnO3 and stainless steel 301 alloys will be measured subsequently. The addition of X-ray diffraction to the unique split coil magnet will significantly expand the NHMFL experimental capabilities. Therefore, external users will be able to probe spin - lattice interactions at static magnetic fields up to 25T. This project is supported by NSF-DMR Award No.1257649. NHMFL is supported by NSF Cooperative Agreement No. DMR-1157490, the State of Florida, and the U.S. DoE.

  15. Hip imaging of avascular necrosis at 7 Tesla compared with 3 Tesla

    Energy Technology Data Exchange (ETDEWEB)

    Theysohn, J.M.; Kraff, O.; Theysohn, N.; Orzada, S.; Lauenstein, T.C. [University Duisburg-Essen, Erwin L. Hahn Institute for Magnetic Resonance Imaging, Essen (Germany); University Hospital Essen, Institute for Diagnostic and Interventional Radiology and Neuroradiology, Essen (Germany); Landgraeber, S. [University Hospital Essen, Department of Orthopedic Surgery, Essen (Germany); Ladd, M.E. [University Duisburg-Essen, Erwin L. Hahn Institute for Magnetic Resonance Imaging, Essen (Germany); German Cancer Research Center, Department of Medical Physics in Radiology, Heidelberg (Germany)

    2014-05-15

    To compare ultra-high field, high-resolution bilateral magnetic resonance imaging (MRI) of the hips at 7 Tesla (T) with 3 T MRI in patients with avascular necrosis (AVN) of the femoral head by subjective image evaluations, contrast measurements, and evaluation of the appearance of imaging abnormalities. Thirteen subjects with avascular necrosis treated using advanced core decompression underwent MRI at both 7 T and 3 T. Sequence parameters as well as resolution were kept identical for both field strengths. All MR images (MEDIC, DESS, PD/T2w TSE, T1w TSE, and STIR) were evaluated by two radiologists with regard to subjective image quality, soft tissue contrasts, B1 homogeneity (four-point scale, higher values indicating better image quality) and depiction of imaging abnormalities of the femoral heads (three-point scale, higher values indicating the superiority of 7 T). Contrast ratios of soft tissues were calculated and compared with subjective data. 7-T imaging of the femoral joints, as well as 3-T imaging, achieved ''good'' to ''very good'' quality in all sequences. 7 T showed significantly higher soft tissue contrasts for T2w and MEDIC compared with 3 T (cartilage/fluid: 2.9 vs 2.2 and 3.6 vs 2.6), better detailed resolution for cartilage defects (PDw, T2w, T1w, MEDIC, DESS > 2.5) and better visibility of joint effusions (MEDIC 2.6; PDw/T2w 2.4; DESS 2.2). Image homogeneity compared with 3 T (3.9-4.0 for all sequences) was degraded, especially in TSE sequences at 7 T through signal variations (7 T: 2.1-2.9); to a lesser extent also GRE sequences (7 T: 2.9-3.5). Imaging findings related to untreated or treated AVN were better delineated at 3 T (≤1.8), while joint effusions (2.2-2.6) and cartilage defects (2.5-3.0) were better visualized at 7 T. STIR performed much more poorly at 7 T, generating large contrast variations (1.5). 7-T hip MRI showed comparable results in hip joint imaging compared with 3 T with slight

  16. Focused tight dressing does not prevent cochlear implant magnet migration under 1.5 Tesla MRI.

    Science.gov (United States)

    Cuda, D; Murri, A; Succo, G

    2013-04-01

    We report a retrospective case of inner magnet migration, which occurred after 1.5 Tesla MRI scanning in an adult recipient of a bilateral cochlear implant (CI) despite a focused head dressing. The patient, bilaterally implanted with Nucleus 5 CIs (Cochlear LTD, Sydney, Australia), underwent a 1.5 Tesla cholangio-MRI scan for biliary duct pathology. In subsequent days, a focal skin alteration appeared over the left inner coil. Plain skull radiographs showed partial magnet migration on the left side. Surgical exploration confirmed magnet twisting; the magnet was effectively repositioned. Left CI performance was restored to pre-migration level. The wound healed without complications. Thus, focused dressing does not prevent magnet migration in CI recipients undergoing 1.5 Tesla MRI. All patients should be counselled on this potential complication. A minor surgical procedure is required to reposition the magnet. Nevertheless, timely diagnosis is necessary to prevent skin breakdown and subsequent device contamination. Plain skull radiograph is very effective in identifying magnet twisting; it should be performed systematically after MRI or minimally on all suspected cases.

  17. Conceptual studies of toroidal field magnets for the tokamak experimental power reactor. Final report

    International Nuclear Information System (INIS)

    Buncher, B.R.; Chi, J.W.H.; Fernandez, R.

    1976-01-01

    This report documents the principal results of a Conceptual Design Study for the Superconducting Toroidal Field System for a Tokamak Experimental Power Reactor. Two concepts are described for peak operating fields at the windings of 8 tesla, and 12 tesla, respectively. The design and manufacturing considerations are treated in sufficient detail that cost and schedule estimates could be developed. Major uncertainties in the design are identified and their potential impact discussed, along with recommendations for the necessary research and development programs to minimize these uncertainties. The minimum dimensions of a sub-size test coil for experimental qualification of the full size design are developed and a test program is recommended

  18. A six-channel pediatric coil array for detection of children spinal pathologies by MRI at 1.5 Tesla

    Energy Technology Data Exchange (ETDEWEB)

    López Terrones, Marcos Alonso, E-mail: malt.marcos@gmail.com [Ingeniería Biomédica, Dirección de Planeación, Servicios de Salud de Durango. Cuauhtémoc 225 Norte, Durango, Durango 34000 (Mexico); Solís-Nájera, Sergio Enrique, E-mail: solisnajera@ciencias.unam.mx [Facultad de Ciencias, Universidad Nacional Autónoma de México, México, DF 04510 (Mexico)

    2014-11-07

    Nowadays, magnetic resonance (MR) in Mexico has become a standard technique for clinical imaging. Although most of the times the MR systems contain only coils oriented for adults. Radiologists use these coils for children studies due to the non-availability of pediatric coils. Image quality is decreased due to the low signal to noise ratio delivered to the system. The development of RF coils is always focused towards increasing SNR and optimizing the RF penetration into the sample. Moreover, spinal pathologies in children, which are an important topic in pediatric care, cover congenital and neuromuscular disorders that occur in childhood. In this work, the design of a dedicated six-channel coil for detection of spinal pathologies at 1.5 Tesla is addressed. Numerical electromagnetic simulations were performed in order to evaluate their magnetic field performance at (63.6 MHz) 1.5 Tesla. The magnetic field uniformity as well as the RF penetration depth of the coil configurations was evaluated in order to find the best/optimized coil array configuration. The coil is comprised of three rows, one with 4 coil elements and two with only one coil element. Phantom and in vivo images were acquired with the six-channel pediatric coil array. The phantom images agree with the simulated data. In vivo images acquired with the 6-channel pediatric coil array have shown very good penetration depth and homogeneity, which allow better image quality throughout the whole FOV. In addition, the parallel imaging capabilities of the array allow the acceleration of the experiments avoiding possible motion artifacts.

  19. A six-channel pediatric coil array for detection of children spinal pathologies by MRI at 1.5 Tesla

    Science.gov (United States)

    López Terrones, Marcos Alonso; Solís-Nájera, Sergio Enrique

    2014-11-01

    Nowadays, magnetic resonance (MR) in Mexico has become a standard technique for clinical imaging. Although most of the times the MR systems contain only coils oriented for adults. Radiologists use these coils for children studies due to the non-availability of pediatric coils. Image quality is decreased due to the low signal to noise ratio delivered to the system. The development of RF coils is always focused towards increasing SNR and optimizing the RF penetration into the sample. Moreover, spinal pathologies in children, which are an important topic in pediatric care, cover congenital and neuromuscular disorders that occur in childhood. In this work, the design of a dedicated six-channel coil for detection of spinal pathologies at 1.5 Tesla is addressed. Numerical electromagnetic simulations were performed in order to evaluate their magnetic field performance at (63.6 MHz) 1.5 Tesla. The magnetic field uniformity as well as the RF penetration depth of the coil configurations was evaluated in order to find the best/optimized coil array configuration. The coil is comprised of three rows, one with 4 coil elements and two with only one coil element. Phantom and in vivo images were acquired with the six-channel pediatric coil array. The phantom images agree with the simulated data. In vivo images acquired with the 6-channel pediatric coil array have shown very good penetration depth and homogeneity, which allow better image quality throughout the whole FOV. In addition, the parallel imaging capabilities of the array allow the acceleration of the experiments avoiding possible motion artifacts.

  20. Test Results for HD1, a 16 Tesla Nb3Sn Dipole Magnet

    International Nuclear Information System (INIS)

    Lietzke, A.F.; Bartlett, S.; Bish, P.; Caspi, S.; Chiesa, L.; Dietderich, D.; Ferracin, P.; Gourlay, S.A.; Goli, M.; Hafalia, R.R.; Higley, H.; Hannaford, R.; Lau, W.; Liggens, N.; Mattafirri, S.; McInturff, A.; Nyman, M.; Sabbi, G.; Scanlan, R.; Swanson, J.

    2003-01-01

    The Superconducting Magnet Group at Lawrence Berkeley National Laboratory has been developing the technology for using brittle superconductor in high-field accelerator magnets. HD1, the latest in a series of magnets, contains two, double-layer Nb 3 Sn flat racetrack coils. This single-bore dipole configuration, using the highest performance conductor available, was designed and assembled for a 16 tesla conductor/structure/pre-stress proof-of-principle. With the combination of brittle conductor and high Lorentz stress, considerable care was taken to predict the magnet's mechanical responses to pre-stress, cool-down, and excitation. Subsequent cold testing satisfied expectations: Training started at 13.6 T, 83% of 'short-sample', achieved 90% in 10 quenches, and reached its peak bore field (16 T) after 19 quenches. The average plateau, ∼92% of 'short-sample', appeared to be limited by 'stick-slip' conductor motions, consistent with the 16.2 T conductor 'lift-off' pre-stress that was chosen for this first test. Some lessons learned and some implications for future conductor and magnet technology development are presented and discussed.

  1. Comparison of Deep Brain Stimulation Lead Targeting Accuracy and Procedure Duration between 1.5- and 3-Tesla Interventional Magnetic Resonance Imaging Systems: An Initial 12-Month Experience.

    Science.gov (United States)

    Southwell, Derek G; Narvid, Jared A; Martin, Alastair J; Qasim, Salman E; Starr, Philip A; Larson, Paul S

    2016-01-01

    Interventional magnetic resonance imaging (iMRI) allows deep brain stimulator lead placement under general anesthesia. While the accuracy of lead targeting has been described for iMRI systems utilizing 1.5-tesla magnets, a similar assessment of 3-tesla iMRI procedures has not been performed. To compare targeting accuracy, the number of lead targeting attempts, and surgical duration between procedures performed on 1.5- and 3-tesla iMRI systems. Radial targeting error, the number of targeting attempts, and procedure duration were compared between surgeries performed on 1.5- and 3-tesla iMRI systems (SmartFrame and ClearPoint systems). During the first year of operation of each system, 26 consecutive leads were implanted using the 1.5-tesla system, and 23 consecutive leads were implanted using the 3-tesla system. There was no significant difference in radial error (Mann-Whitney test, p = 0.26), number of lead placements that required multiple targeting attempts (Fisher's exact test, p = 0.59), or bilateral procedure durations between surgeries performed with the two systems (p = 0.15). Accurate DBS lead targeting can be achieved with iMRI systems utilizing either 1.5- or 3-tesla magnets. The use of a 3-tesla magnet, however, offers improved visualization of the target structures and allows comparable accuracy and efficiency of placement at the selected targets. © 2016 S. Karger AG, Basel.

  2. Estimation of genetic effects of static magnetic fields (SMFs) on the pollen mother cells (PMCs) of wheats

    International Nuclear Information System (INIS)

    Zhang Pingping; Yin Ruochun; Tang Mingli; Wu Yuejin; Yu Zengliang

    2007-01-01

    The effect of static magnetic fields (SMFs) on the chromosome aberrations in the pollen mother cells (PMCs) of wheat was studied. The seeds of wheat were exposed to static magnetic fields of different magnetic flux density (0, 1, 3, 5 and 7 Tesla) for 5h and with different treated time (1, 3 and 5h) at magnetic flux density of 7 Tesla. The genotoxic effect was evaluated in terms of micronucleus (MN), chromosomal bridge, lagging chromosome, abnormal segregation and fragment in PMCs. The results indicated that the exposed groups of low field intensity (below 5 Tesla) showed no statistically significant difference in aberration frequency compared with unexposed control groups and sham exposed groups, but significant differences of chromosomal bridge at 5T and lagging chromosome, triple-polar segregation or micronucleus at 7T were detected in the exposed group (p<0.05). The dose-effect relationships indicated that the increase frequency of meiotic abnormal cells correlated with flux density of magnetic field and treated time, but no linear effect was observed. These results lead us to the conclusion that high static magnetic fields above 5T for 5h duration might cause an increase in potential damage to organisms. (authors)

  3. Investigation of parts and elements of technical reports in nuclear field in Japan

    International Nuclear Information System (INIS)

    Naramoto, Miyoko; Narui, Shigeko

    1985-01-01

    Presentation of parts and elements necessary for editing and publishing reports in accordance with SIST-09-1984 (Presentation of Scientific and Technical Reports) was investigated for 65 codes of technical reports in the nuclear field in Japan. English presentation of important elements was also investigated additionally. The investigation shows high presentation fractions (80 -- 100 %) for main bibliographic elements, and medium (66 %) and extremely low (3 %) for abntract and key word, respectively. (The bibliographic elements are described in various parts such as front cover, title page and front matter) and (the subject elements appear mainly in front matter). The title, author's name in Roman character, affiliation, publisher and abstract are described in English with fractions of 80 %, 66 %, 68 % and 62 %, respectively. It is hoped for more publishers and editors of technical reports to accept the standard SIST-09 for efficient processing of secondary information. (author)

  4. Status of the GA/MCA 12 Tesla Coil Development Program

    International Nuclear Information System (INIS)

    Alcorn, J.S.; Purcell, J.R.; Chen, W.Y.; Hsu, Y.H.

    1980-09-01

    The current status of the Team One effort of the DOE/OFE/D and T 12 Tesla Coil Development Program is presented. Subatmospheric, helium bath cooled, NbTiTa alloy is employed for the test coil, and ETF TF-coil concept. General Atomic is the Team One leader, with Magnetic Corporation of American as industrial subcontractor

  5. Tesla coil discharges guided by femtosecond laser filaments in air

    Science.gov (United States)

    Brelet, Yohann; Houard, Aurélien; Arantchouk, Leonid; Forestier, Benjamin; Liu, Yi; Prade, Bernard; Carbonnel, Jérôme; André, Yves-Bernard; Mysyrowicz, André

    2012-04-01

    A Tesla coil generator was designed to produce high voltage pulses oscillating at 100 kHz synchronisable with a nanosecond temporal jitter. Using this compact high voltage generator, we demonstrate reproducible meter long discharges in air at a repetition rate of 1 Hz. Triggering and guiding of the discharges are performed in air by femtosecond laser filaments.

  6. Seven-Tesla Magnetization Transfer Imaging to Detect Multiple Sclerosis White Matter Lesions.

    Science.gov (United States)

    Chou, I-Jun; Lim, Su-Yin; Tanasescu, Radu; Al-Radaideh, Ali; Mougin, Olivier E; Tench, Christopher R; Whitehouse, William P; Gowland, Penny A; Constantinescu, Cris S

    2018-03-01

    Fluid-attenuated inversion recovery (FLAIR) imaging at 3 Tesla (T) field strength is the most sensitive modality for detecting white matter lesions in multiple sclerosis. While 7T FLAIR is effective in detecting cortical lesions, it has not been fully optimized for visualization of white matter lesions and thus has not been used for delineating lesions in quantitative magnetic resonance imaging (MRI) studies of the normal appearing white matter in multiple sclerosis. Therefore, we aimed to evaluate the sensitivity of 7T magnetization-transfer-weighted (MT w ) images in the detection of white matter lesions compared with 3T-FLAIR. Fifteen patients with clinically isolated syndrome, 6 with multiple sclerosis, and 10 healthy participants were scanned with 7T 3-dimensional (D) MT w and 3T-2D-FLAIR sequences on the same day. White matter lesions visible on either sequence were delineated. Of 662 lesions identified on 3T-2D-FLAIR images, 652 were detected on 7T-3D-MT w images (sensitivity, 98%; 95% confidence interval, 97% to 99%). The Spearman correlation coefficient between lesion loads estimated by the two sequences was .910. The intrarater and interrater reliability for 7T-3D-MT w images was good with an intraclass correlation coefficient (ICC) of 98.4% and 81.8%, which is similar to that for 3T-2D-FLAIR images (ICC 96.1% and 96.7%). Seven-Tesla MT w sequences detected most of the white matter lesions identified by FLAIR at 3T. This suggests that 7T-MT w imaging is a robust alternative for detecting demyelinating lesions in addition to 3T-FLAIR. Future studies need to compare the roles of optimized 7T-FLAIR and of 7T-MT w imaging. © 2017 The Authors. Journal of Neuroimaging published by Wiley Periodicals, Inc. on behalf of American Society of Neuroimaging.

  7. Conceptual design of a superconducting coil system cooled by forced flow HE II for the central column of net

    International Nuclear Information System (INIS)

    Ciazynski, D.; Duchateau, J.L.; Turck, B.

    1987-01-01

    In order to increase the maximum flux sweep, a present trend is to design ohmic coils producing fields as high as II teslas. In Niobium-Titanium, critical current densities of 10 9 A/m 2 at 1.8 K under a field of 11 teslas are now claimed by several manufacturers. This in addition enables to make use of the outstanding cooling properties of He II. The forced flow technics can again be envisaged for He II to remove the heat load. Two solutions are investigated. The first one uses a 40 kA cable wound in double pancakes. The second one makes use of several conductors layer wound and current supplied in parallel

  8. Use of Tesla NZK 203 neutron probe in studying water as geochemical factor in weathering zone

    International Nuclear Information System (INIS)

    Hally, J.

    1980-01-01

    The Tesla NZK 203 neutron moisture gage was used for determining soil moisture in depths of 1 and 2 meters in the Luha-Kacerov profile in the Zelivka water reservoir basin. The borehole spacing was 100 m. Measurements were made once a month between May and October 1978. The results were compared with the granulometric composition and the values of the specific surface areas of earths in the area. The Tesla NZK 203 moisture gage was fully proven for speedy measurement of volume moisture at constant measuring points. (Ha)

  9. Elon Musk – riskanter Milliardenpoker um Tesla & Co.

    OpenAIRE

    Lipp, Reto

    2017-01-01

    Interview von Reto Lipp mit Peter Leibfried (SRF ECO): Von seinen Fans wird er wie ein Rockstar gefeiert. Ob Tesla, Solar City oder SpaceX, Elon Musk will die Welt revolutionieren. Doch seine Visionen verschlingen Unsummen. Bisher ist es ihm stets gelungen, neue Gelder zu mobilisieren und bei Bedarf Millionenbeträge zwischen seinen Unternehmen hin und her zu schieben. Doch das Firmenimperium lebt von riesigen Erwartungen der Investoren. Kann Elon Musk sie nicht einlösen, droht der Kollaps.

  10. Anatomy and metabolism of the normal human brain studied by magnetic resonance at 1.5 Tesla

    International Nuclear Information System (INIS)

    Bottomley, P.A.; Hart, H.R. Jr.; Edelstein, W.A.; Schenck, J.F.; Smith, L.S.; Leue, W.M.; Mueller, O.M.; Redington, R.W.

    1984-01-01

    Proton magnetic resonance (MR) images were obtained of the human head in magnetic fields as high as 1.5 Tesla (T) using slotted resonator high radio-frequency (RF) detection coils. The images showed no RF field penetration problems and exhibited an 11 (+/-1)-fold improvement in signal-to-noise ratio over a .12-T imaging system. The first localized phosphorus 31, carbon 13, and proton MR chemical shift spectra recorded with surface coils from the head and body in the same instrument showed relative concentrations of phosphorus metabolites, triglycerides, and, when correlated with proton images, negligible lipid (-CH 2 -) signal from brain tissue on the time scale of the imaging experiment. Sugar phosphate and phosphodiester concentrations were significantly elevated in the head compared with muscle. This method should allow the combined assessment of anatomy, metabolism, and biochemistry in both the normal and diseased brain

  11. A Study of Thermocurrent Induced Magnetic Fields in ILC Cavities

    Energy Technology Data Exchange (ETDEWEB)

    Crawford, Anthony C. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Cooley, Victoria [Univ. of Wisconsin, Madison, WI (United States)

    2014-03-31

    The case of axisymmetric ILC-type cavities with titanium helium vessels is investigated. A first-order estimate for magnetic field within the SRF current layer is presented. The induced magnetic field is found to be not more than 1.4x10-8 Tesla = 0.14 milligauss for the case of axial symmetry. Magnetic fields due to symmetry breaking effects are discussed.

  12. Tissue expander stimulated lengthening of arteries (TESLA) induces early endothelial cell proliferation in a novel rodent model.

    Science.gov (United States)

    Potanos, Kristina; Fullington, Nora; Cauley, Ryan; Purcell, Patricia; Zurakowski, David; Fishman, Steven; Vakili, Khashayar; Kim, Heung Bae

    2016-04-01

    We examine the mechanism of aortic lengthening in a novel rodent model of tissue expander stimulated lengthening of arteries (TESLA). A rat model of TESLA was examined with a single stretch stimulus applied at the time of tissue expander insertion with evaluation of the aorta at 2, 4 and 7day time points. Measurements as well as histology and proliferation assays were performed and compared to sham controls. The aortic length was increased at all time points without histologic signs of tissue injury. Nuclear density remained unchanged despite the increase in length suggesting cellular hyperplasia. Cellular proliferation was confirmed in endothelial cell layer by Ki-67 stain. Aortic lengthening may be achieved using TESLA. The increase in aortic length can be achieved without tissue injury and results at least partially from cellular hyperplasia. Further studies are required to define the mechanisms involved in the growth of arteries under increased longitudinal stress. Copyright © 2015 Elsevier Inc. All rights reserved.

  13. MRI at 3 Tesla detects no evidence for ischemic brain damage in intensively treated patients with homozygous familial hypercholesterolemia

    Energy Technology Data Exchange (ETDEWEB)

    Schmitz, Stephan A.; O' Regan, Declan P.; Fitzpatrick, Julie; Hajnal, Joseph V. [Hammersmith Hospital Campus, Imaging Sciences Department, MRC Clinical Sciences Centre, Faculty of Medicine, Imperial College, London (United Kingdom); Neuwirth, Clare; Potter, Elizabeth; Tosi, Isabella; Naoumova, Rossi P. [MRC Clinical Sciences Centre, Clinical Research Facility, London (United Kingdom); Hammersmith Hospital, Lipid Clinic, London (United Kingdom)

    2007-11-15

    Homozygous familial hypercholesterolemia (FH) is considered a model disease for excessive plasma cholesterol levels. Patients with untreated homozygous FH have a markedly increased risk for premature atherosclerosis. The frequency and extent of ischemic brain damage detectable by high-field magnetic resonance imaging (MRI) after long-term intensive treatment are unknown. In a case control study, five patients with homozygous FH (one male and four females; mean age: 23.6 {+-} 9.2, range: 12-36 years; mean pre-treatment serum total cholesterol level: 26.9 {+-} 3.24 mmol/L; all patients with documented atherosclerotic plaques in the carotid arteries) and five age- and sex-matched healthy controls were studied. All patients had been on maximal lipid-lowering medication since early childhood, and four of them were also on treatment with low-density lipoprotein (LDL) apheresis at bi-weekly intervals. Brain MRI was performed at 3 Tesla field strength with fluid-attenuated T2-weighted inversion recovery and T1-weighted spin-echo MR pulse sequences and subsequently evaluated by two independent readers. The maximal lipid-lowering treatment reduced the total serum cholesterol by more than 50% in the patients, but their serum concentrations were still 3.6-fold higher than those found in the controls (11.9 {+-} 4.2 vs. 4.5 {+-} 0.5 mmol/L; p < 0.0047). No brain abnormality was observed in any of the patients with homozygous FH. Homozygous FH patients on intensive cholesterol-lowering therapy have no evidence of ischemic brain damage at 3 Tesla MRI despite the remaining high cholesterol levels. (orig.)

  14. MRI at 3 Tesla detects no evidence for ischemic brain damage in intensively treated patients with homozygous familial hypercholesterolemia

    International Nuclear Information System (INIS)

    Schmitz, Stephan A.; O'Regan, Declan P.; Fitzpatrick, Julie; Hajnal, Joseph V.; Neuwirth, Clare; Potter, Elizabeth; Tosi, Isabella; Naoumova, Rossi P.

    2007-01-01

    Homozygous familial hypercholesterolemia (FH) is considered a model disease for excessive plasma cholesterol levels. Patients with untreated homozygous FH have a markedly increased risk for premature atherosclerosis. The frequency and extent of ischemic brain damage detectable by high-field magnetic resonance imaging (MRI) after long-term intensive treatment are unknown. In a case control study, five patients with homozygous FH (one male and four females; mean age: 23.6 ± 9.2, range: 12-36 years; mean pre-treatment serum total cholesterol level: 26.9 ± 3.24 mmol/L; all patients with documented atherosclerotic plaques in the carotid arteries) and five age- and sex-matched healthy controls were studied. All patients had been on maximal lipid-lowering medication since early childhood, and four of them were also on treatment with low-density lipoprotein (LDL) apheresis at bi-weekly intervals. Brain MRI was performed at 3 Tesla field strength with fluid-attenuated T2-weighted inversion recovery and T1-weighted spin-echo MR pulse sequences and subsequently evaluated by two independent readers. The maximal lipid-lowering treatment reduced the total serum cholesterol by more than 50% in the patients, but their serum concentrations were still 3.6-fold higher than those found in the controls (11.9 ± 4.2 vs. 4.5 ± 0.5 mmol/L; p < 0.0047). No brain abnormality was observed in any of the patients with homozygous FH. Homozygous FH patients on intensive cholesterol-lowering therapy have no evidence of ischemic brain damage at 3 Tesla MRI despite the remaining high cholesterol levels. (orig.)

  15. Rectal cancer confined to the bowel wall: the role of 3 Tesla phased-array MR imaging in T categorization.

    Science.gov (United States)

    Çolakoğlu Er, Hale; Peker, Elif; Erden, Ayşe; Erden, İlhan; Geçim, Ethem; Savaş, Berna

    2018-02-01

    To determine the diagnostic value of 3 Tesla MR imaging in detection of mucosal (Tis), submucosal (T 1 ) and muscularis propria (T 2 ) invasion in patients with early rectal cancer. A total of 50 consecutive patients who underwent 3 Tesla MR imaging and curative-intent intervention for MRI-staged Tis/T 1 /T 2 rectal cancer from March 2012 to December 2016 were included. The radiological T category of each rectal tumour was compared retrospectively with histopathological results assessed according to the tumor, node, metastasis (TNM) classification. The sensitivities, specificities, and overall accuracy rates of 3 Tesla MR imaging for Tis, T 1 , and T 2 cases were calculated using MedCalc statistical software v. 16. The sensitivity, specificity, PPV, NPV of 3 Tesla MR imaging in T categorization for T 2 were: 93.7% [95% CI (0.79-0.99)], 77.7% [95% CI (0.52-0.93)], 88.2% [95% CI (0.75-0.94)] and 87.5% [95% CI (0.64-0.96)]; for T 1 were 92% [95% CI (0.63-0.99)], 91.8% [95% CI (0.78-0.98)], 80% [95% CI (0.57-0.92)] and 97.1% [95% CI (0.83-0.99)]; for Tis were: 20% [95% CI (0.51-0.71)], 100% [95% CI (0.92-1)], 100%, 91.8% [95% CI (0.87-0.94)], respectively. MR categorization accuracy rates for T 2 , T 1 and Tis were calculated as 88, 92 and 92%, respectively. 3 Tesla MR imaging seems to be useful for accurate categorization of T-stage in early rectal cancer, especially for T 1 cancers. The method is not a reliable tool to detect Tis cases. The potential for overstaging and understaging of the technique should be realized and taken into consideration when tailoring the treatment protocol for each patient. Advances in knowledge: High-resolution MR with phased-array coil is being increasingly used in the pre-operative assessment of rectal cancer. 3 Tesla high-resolution MR imaging allows improved definition of bowel wall and tumour infiltration.

  16. Fast T1 and T2 mapping methods: the zoomed U-FLARE sequence compared with EPI and snapshot-FLASH for abdominal imaging at 11.7 Tesla.

    Science.gov (United States)

    Pastor, Géraldine; Jiménez-González, María; Plaza-García, Sandra; Beraza, Marta; Reese, Torsten

    2017-06-01

    A newly adapted zoomed ultrafast low-angle RARE (U-FLARE) sequence is described for abdominal imaging applications at 11.7 Tesla and compared with the standard echo-plannar imaging (EPI) and snapshot fast low angle shot (FLASH) methods. Ultrafast EPI and snapshot-FLASH protocols were evaluated to determine relaxation times in phantoms and in the mouse kidney in vivo. Owing to their apparent shortcomings, imaging artefacts, signal-to-noise ratio (SNR), and variability in the determination of relaxation times, these methods are compared with the newly implemented zoomed U-FLARE sequence. Snapshot-FLASH has a lower SNR when compared with the zoomed U-FLARE sequence and EPI. The variability in the measurement of relaxation times is higher in the Look-Locker sequences than in inversion recovery experiments. Respectively, the average T1 and T2 values at 11.7 Tesla are as follows: kidney cortex, 1810 and 29 ms; kidney medulla, 2100 and 25 ms; subcutaneous tumour, 2365 and 28 ms. This study demonstrates that the zoomed U-FLARE sequence yields single-shot single-slice images with good anatomical resolution and high SNR at 11.7 Tesla. Thus, it offers a viable alternative to standard protocols for mapping very fast parameters, such as T1 and T2, or dynamic processes in vivo at high field.

  17. Safety implications of high-field MRI: actuation of endogenous magnetic iron oxides in the human body.

    Directory of Open Access Journals (Sweden)

    Jon Dobson

    Full Text Available Magnetic Resonance Imaging scanners have become ubiquitous in hospitals and high-field systems (greater than 3 Tesla are becoming increasingly common. In light of recent European Union moves to limit high-field exposure for those working with MRI scanners, we have evaluated the potential for detrimental cellular effects via nanomagnetic actuation of endogenous iron oxides in the body.Theoretical models and experimental data on the composition and magnetic properties of endogenous iron oxides in human tissue were used to analyze the forces on iron oxide particles.Results show that, even at 9.4 Tesla, forces on these particles are unlikely to disrupt normal cellular function via nanomagnetic actuation.

  18. SRS Behaviour with a superconducting 5-Tesla wiggler insertion

    International Nuclear Information System (INIS)

    Suller, V.P.; Marks, N.; Poole, M.W.; Walker, R.P.

    1983-01-01

    A 5 Tesla superconducting wavelength shifting wiggler magnet has been inserted into the SRS lattice. Observations have been made of the behaviour of the stored electron beam with the magnet powered. Betatron tune shifts and modulation of the betatron function have been measured and good agreement obtained with theory. Closed orbit changes have been examined and the stored beam lifetime optimised. The magnet is fully operational and is producing intense x-ray beams for users

  19. Occupational exposure of healthcare and research staff to static magnetic stray fields from 1.5–7 Tesla MRI scanners is associated with reporting of transient symptoms

    Science.gov (United States)

    Schaap, Kristel; Christopher-de Vries, Yvette; Mason, Catherine K; de Vocht, Frank; Portengen, Lützen; Kromhout, Hans

    2014-01-01

    Objectives Limited data is available about incidence of acute transient symptoms associated with occupational exposure to static magnetic stray fields from MRI scanners. We aimed to assess the incidence of these symptoms among healthcare and research staff working with MRI scanners, and their association with static magnetic field exposure. Methods We performed an observational study among 361 employees of 14 clinical and research MRI facilities in The Netherlands. Each participant completed a diary during one or more work shifts inside and/or outside the MRI facility, reporting work activities and symptoms (from a list of potentially MRI-related symptoms, complemented with unrelated symptoms) experienced during a working day. We analysed 633 diaries. Exposure categories were defined by strength and type of MRI scanner, using non-MRI shifts as the reference category for statistical analysis. Non-MRI shifts originated from MRI staff who also participated on MRI days, as well as CT radiographers who never worked with MRI. Results Varying per exposure category, symptoms were reported during 16–39% of the MRI work shifts. We observed a positive association between scanner strength and reported symptoms among healthcare and research staff working with closed-bore MRI scanners of 1.5 Tesla (T) and higher (1.5 T OR=1.88; 3.0 T OR=2.14; 7.0 T OR=4.17). This finding was mainly driven by reporting of vertigo and metallic taste. Conclusions The results suggest an exposure-response association between exposure to strong static magnetic fields (and associated motion-induced time-varying magnetic fields) and reporting of transient symptoms on the same day of exposure. Trial registration number 11-032/C PMID:24714654

  20. Single session imaging of cerebellum at 7 Tesla: obtaining structure and function of multiple motor subsystems in individual subjects.

    Directory of Open Access Journals (Sweden)

    Melissa A Batson

    Full Text Available The recent increase in the use of high field MR systems is accompanied by a demand for acquisition techniques and coil systems that can take advantage of increased power and accuracy without being susceptible to increased noise. Physical location and anatomical complexity of targeted regions must be considered when attempting to image deeper structures with small nuclei and/or complex cytoarchitechtonics (i.e. small microvasculature and deep nuclei, such as the brainstem and the cerebellum (Cb. Once these obstacles are overcome, the concomitant increase in signal strength at higher field strength should allow for faster acquisition of MR images. Here we show that it is technically feasible to quickly and accurately detect blood oxygen level dependent (BOLD signal changes and obtain anatomical images of Cb at high spatial resolutions in individual subjects at 7 Tesla in a single one-hour session. Images were obtained using two high-density multi-element surface coils (32 channels in total placed beneath the head at the level of Cb, two channel transmission, and three-dimensional sensitivity encoded (3D, SENSE acquisitions to investigate sensorimotor activations in Cb. Two classic sensorimotor tasks were used to detect Cb activations. BOLD signal changes during motor activity resulted in concentrated clusters of activity within the Cb lobules associated with each task, observed consistently and independently in each subject: Oculomotor vermis (VI/VII and CrusI/II for pro- and anti-saccades; ipsilateral hemispheres IV-VI for finger tapping; and topographical separation of eye- and hand- activations in hemispheres VI and VIIb/VIII. Though fast temporal resolution was not attempted here, these functional patches of highly specific BOLD signal changes may reflect small-scale shunting of blood in the microvasculature of Cb. The observed improvements in acquisition time and signal detection are ideal for individualized investigations such as

  1. Technical and economic feasibility study of flue gas injection in an Iranian oil field

    Directory of Open Access Journals (Sweden)

    Mohammad Ali Ahmadi

    2015-09-01

    The main aim of this research is to investigate various gas injection methods (N2, CO2, produced reservoir gas, and flue gas in one of the northern Persian gulf oil fields by a numerical simulation method. Moreover, for each scenario of gas injection technical and economical considerations are took into account. Finally, an economic analysis is implemented to compare the net present value (NPV of the different gas injection scenarios in the aforementioned oil field.

  2. The IEEE guide to writing in the engineering and technical fields

    CERN Document Server

    Kmiec, David

    2017-01-01

    This book introduces students and practicing engineers to all the components of writing in the workplace. It teaches readers how considerations of audience and purpose govern the structure of their documents within particular work settings. The IEEE Guide to Writing in the Engineering and Technical Fields is broken up into two sections: "Writing in Engineering Organizations" and "What Can You Do With Writing?" The first section helps readers approach their writing in a logical and persuasive way as well as analyze their purpose for writing. The second section demonstrates how to distinguish rhetorical situations and the generic forms to inform, train, persuade, and collaborate. The emergence of the global workplace has brought with it an increasingly important role for effective technical communication. Engineers more often need to work in cross-functional teams with people in different disciplines, in different countries, and in different parts of the world. Engineers must know how to communicate in a rapid...

  3. EQUACIONAMENTO E MODELAGEM DA BOBINA BIFILAR DE TESLA

    Directory of Open Access Journals (Sweden)

    Caio Marcelo de Marcelo de Miranda

    2012-01-01

    Full Text Available A Biotelemetria apresenta-se como uma importante técnica que possui várias aplicações na área de Biomedicina e outras. A dimensão da unidade remota ou sensora constitui um grande desafio dentro desta área, sendo que na maioria dos casos,deseja-se uma unidade o menor possível. Desta maneira, sensores passivos são interessantes, pois possibilitam uma menor dimensão do dispositivo e não necessitam de uma fonte própria de energia, ou bateria, que pode causar danos ao indivíduo monitorado caso ocorra vazamento do seu conteúdo químico. Deste modo,o sensor indutivo autorressonante apresenta-se como uma boa solução, uma vez que este pode ser construído com apenas um componente, neste caso um indutor.Por apresentar pequenas dimensões, este tipo de sensor possui uma baixa capacitância parasita, o que torna a sua frequência de ressonância bastante alta. Neste caso, a bobina bifilar idealizada por Nikola Tesla pode constituir-se de uma solução, uma vez que a idéia de Tesla era de aumentar a capacitância intrínseca de suas bobinas. Portanto, um entendimento físico e devido equacionamento da bobina bifilar se faz necessário, uma vez que, até onde se sabe, este tipo de abordagem não existe na literatura.A partir de uma análise das tensões entre espiras adjacentes, foi desenvolvido neste trabalho um equacionamento da bobina bifilar de Tesla, possibilitando a determinação do aumento da capacitância interna e, consequente, redução na frequência de ressonância desta bobina. Um modelo elétrico equivalente da bobina foi também elaborado através desta análise. Isto possibilita o projeto de bobinas bifilares e predição dos parâmetros capacitância e frequência de autorressonância desta bobina. Testes foram realizados ao comparar a frequência de autorressonância calculada e medida para diversos números de espiras,comprovando a validade do modelo e das equações desenvolvidas.

  4. Measuring the performance of the coaxial HOM coupler on a 2-cell TESLA-shape copper cavity

    International Nuclear Information System (INIS)

    Wang Fang; Wang Erdong; Zhang Baocheng; Zhao Kui

    2009-01-01

    Coaxial High Order Mode (HOM) couplers have been fabricated at Peking University and their RF performance has been measured on a test device consisting of a coaxial transmission line and a 2-cell TESLA-shape copper cavity. The test results on the 2-cell TESLA-shape copper cavity with HOM couplers indicate that the coupler can cut off the fundamental mode TM 010 and absorb HOMs effectively after a careful adjustment. The optimal angle of the HOM coupler with the beam tube is found. The initial test results of HOM couplers are presented in this paper. (authors)

  5. Development of High Field MR Imaging and Spectroscopy Techniques of the Prostate

    NARCIS (Netherlands)

    Arteaga de Castro, C.S.

    2013-01-01

    This thesis summarizes the work of the development of new techniques for obtaining magnetic resonance imaging (MRI) and spectroscopy (MRS) of the prostate at the ultra high field of 7 tesla (T). The 7 T field strength presents various challenges such as the shortening of the wavelength and the lower

  6. Local study of the Mg{sub 1-x}Al{sub x}B{sub 2} single crystals by scanning tunneling spectroscopy in magnetic field up to 3 Tesla

    Energy Technology Data Exchange (ETDEWEB)

    Giubileo, F. [CNR-INFM Laboratorio Regionale SUPERMAT, Dipartimento di Fisica ' E.R. Caianiello' , Universita degli Studi di Salerno, via Salvador Allende, 84081 Baronissi, SA (Italy)], E-mail: giubileo@sa.infn.it; Bobba, F.; Scarfato, A.; Cucolo, A.M. [CNR-INFM Laboratorio Regionale SUPERMAT, Dipartimento di Fisica ' E.R. Caianiello' , Universita degli Studi di Salerno, via Salvador Allende, 84081 Baronissi, SA (Italy); Kohen, A.; Roditchev, D. [Institut des Nanosciences de Paris, INSP, Universite P. et M. Curie Paris 6, CNRS, UMR 75-88, Paris (France); Zhigadlo, N.D.; Karpinski, J. [Solid State Physics Laboratory, ETH Zurich, CH-8093 Zurich (Switzerland)

    2008-04-01

    We have performed local tunneling spectroscopy on high quality Mg{sub 1-x}Al{sub x}B{sub 2} single crystals by means of variable temperature scanning tunneling spectroscopy in magnetic field up to 3 Tesla. Single gap conductance spectra due to c-axis tunneling were extensively measured, probing different amplitudes of the three-dimensional {delta}{sub {pi}} as a function of Al content (i.e. as a function of the critical temperature T{sub C}). Temperature and magnetic field dependences of the conductance spectra were studied in S-I-N configuration: the effect of the doping resulted in a monotonous reduction of the locally measured T{sub C} down to 24 K for x = 0.2. The magnetic field dependence was studied in a local way: An estimation for upper critical field H{sub c2} was inferred from the evolution of the tunneling spectra with the field perpendicular to the sample surface, for different doping levels. The high spatial resolution of the STS technique allowed us to evidence possible non-homogeneities of the superconducting properties on the sample surface with variation of in the same sample depending on different local levels of doping. The locally measured upper critical field resulted to vary for different dopings, and the maximum value H{sub c2}{approx_equal}3T was found for samples with T{sub C}=33 K. The evolution of the density of states (DOS) was found to be characterized by two distinct regimes separated by a crossover region. Our results indicate a rapid suppression of the intrinsic term in {pi}-band superconductivity for 0 T < B < 0.5 T. At high fields (0.8 T < B < 3 T) the superconductivity in the {pi}-band survives uniquely due to the coupling to the {sigma}-band. The shape of tunneling spectra suggests an important role played by the quasiparticle inter-band scattering.

  7. Cavity-Type BPMs For The TESLA Test Facility Free Electron Laser

    CERN Document Server

    Waldmann, H

    2003-01-01

    For measurements of the beam position at the undulator section of the TESLA Test Facility (TTF) at DESY cavity-type beam position monitors were developed, installed and brought into operation. Besides of some theoretical aspects results of in-beam measurements at the TTF are presented and pros and cons of this monitor concept are discussed.

  8. Functional magnetic resonance imaging with ultra-high fields; Funktionelle Magnetresonanztomographie bei ultrahohen Feldern

    Energy Technology Data Exchange (ETDEWEB)

    Windischberger, C.; Schoepf, V.; Sladky, R.; Moser, E. [Medizinische Universitaet Wien, Exzellenzzentrum Hochfeld-MR, Wien (Austria); Medizinische Universitaet Wien, Zentrum fuer Medizinische Physik und Biomedizinische Technik, Wien (Austria); Fischmeister, F.P.S. [Medizinische Universitaet Wien, Exzellenzzentrum Hochfeld-MR, Wien (Austria); Universitaet Wien, Fakultaet fuer Psychologie, Wien (Austria)

    2010-02-15

    Functional magnetic resonance imaging (fMRI) is currently the primary method for non-invasive functional localization in the brain. With the emergence of MR systems with field strengths of 4 Tesla and above, neuronal activation may be studied with unprecedented accuracy. In this article we present different approaches to use the improved sensitivity and specificity for expanding current fMRT resolution limits in space and time based on several 7 Tesla studies. In addition to the challenges that arise with ultra-high magnetic fields possible solutions will be discussed. (orig.) [German] Die funktionelle Magnetresonanztomographie (fMRT) stellt zurzeit die wichtigste Methode zur nichtinvasiven Funktionslokalisation im Gehirn dar. Mit der Verfuegbarkeit von MRT-Geraeten mit Magnetfeldstaerken von 4 Tesla (T) und darueber ergeben sich neue Moeglichkeiten, mittels fMRT die neuronale Aktivitaet in bislang unerreichter Genauigkeit zu untersuchen. In diesem Artikel zeigen wir anhand mehrerer Studien bei 7 T, in wieweit die Zugewinne an Sensitivitaet und Spezifitaet verwendet werden koennen, um die bisherigen Grenzen der fMRT-Aufloesung in raeumlicher und zeitlicher Hinsicht auszuweiten. Die neuen Herausforderungen, die mit dem Schritt zu ultrahohen Magnetfeldern einhergehen, werden dabei ebenso diskutiert wie moegliche Ansaetze zu deren Loesung. (orig.)

  9. Cryomodule tests of the TESLA-like superconducting cavity in KEK-STF

    International Nuclear Information System (INIS)

    Kako, Eiji; Sato, Masato; Shishido, Toshio; Noguchi, Shuichi; Hatori, Hirofumi; Hayano, Hitoshi; Yamamoto, Yasuchika; Watanabe, Ken

    2008-01-01

    Construction of STF (Superconducting RF Test Facility) is being carried out at KEK. The STF-Baseline superconducting cavity system, which includes four TESLA-like 9-cell cavities, input couplers and frequency tuners, has been developed for the future ILC project. A 6-m cryomodule including one of four TESLA-like cavities was assembled, and the cryomodule was installed in the tunnel for the initial test, called the STF Phase-0.5. The first cool-down of the cryomodule and high power tests of the cavity had been carried out at 2 K from October to November, 2007. The maximum accelerating gradient (Eacc, max) of 19.3 MV/m was achieved in a specific pulse width of 1.5 msec and a repetition rate of 5 Hz, (23.4 MV/m in a shorter pulse width of 0.6 msec). Compensation of Lorentz force detuning at 18 MV/m was successfully demonstrated by using a piezo tuner. The second cryomodule test for four cavities, called the STF Phase-1.0, is scheduled in July, 2008. (author)

  10. Magnetic resonance imaging evaluation after implantation of a titanium cervical disc prosthesis: a comparison of 1.5 and 3 Tesla magnet strength.

    Science.gov (United States)

    Sundseth, Jarle; Jacobsen, Eva A; Kolstad, Frode; Nygaard, Oystein P; Zwart, John A; Hol, Per K

    2013-10-01

    Cervical disc prostheses induce significant amount of artifact in magnetic resonance imaging which may complicate radiologic follow-up after surgery. The purpose of this study was to investigate as to what extent the artifact, induced by the frequently used Discover(®) cervical disc prosthesis, impedes interpretation of the MR images at operated and adjacent levels in 1.5 and 3 Tesla MR. Ten subsequent patients were investigated in both 1.5 and 3 Tesla MR with standard image sequences one year following anterior cervical discectomy with arthroplasty. Two neuroradiologists evaluated the images by consensus. Emphasis was made on signal changes in medulla at all levels and visualization of root canals at operated and adjacent levels. A "blur artifact ratio" was calculated and defined as the height of the artifact on T1 sagittal images related to the operated level. The artifacts induced in 1.5 and 3 Tesla MR were of entirely different character and evaluation of the spinal cord at operated level was impossible in both magnets. Artifacts also made the root canals difficult to assess at operated level and more pronounced in the 3 Tesla MR. At the adjacent levels however, the spinal cord and root canals were completely visualized in all patients. The "blur artifact" induced at operated level was also more pronounced in the 3 Tesla MR. The artifact induced by the Discover(®) titanium disc prosthesis in both 1.5 and 3 Tesla MR, makes interpretation of the spinal cord impossible and visualization of the root canals difficult at operated level. Adjusting the MR sequences to produce the least amount of artifact is important.

  11. A 32-channel lattice transmission line array for parallel transmit and receive MRI at 7 tesla.

    Science.gov (United States)

    Adriany, Gregor; Auerbach, Edward J; Snyder, Carl J; Gözübüyük, Ark; Moeller, Steen; Ritter, Johannes; Van de Moortele, Pierre-François; Vaughan, Tommy; Uğurbil, Kâmil

    2010-06-01

    Transmit and receive RF coil arrays have proven to be particularly beneficial for ultra-high-field MR. Transmit coil arrays enable such techniques as B(1) (+) shimming to substantially improve transmit B(1) homogeneity compared to conventional volume coil designs, and receive coil arrays offer enhanced parallel imaging performance and SNR. Concentric coil arrangements hold promise for developing transceiver arrays incorporating large numbers of coil elements. At magnetic field strengths of 7 tesla and higher where the Larmor frequencies of interest can exceed 300 MHz, the coil array design must also overcome the problem of the coil conductor length approaching the RF wavelength. In this study, a novel concentric arrangement of resonance elements built from capacitively-shortened half-wavelength transmission lines is presented. This approach was utilized to construct an array with whole-brain coverage using 16 transceiver elements and 16 receive-only elements, resulting in a coil with a total of 16 transmit and 32 receive channels. (c) 2010 Wiley-Liss, Inc.

  12. Clinical impacts of 3.0 Tesla magnetic resonance imaging in stroke patients

    International Nuclear Information System (INIS)

    Inoue, Takashi; Ogasawara, Kuniaki; Ogawa, Akira

    2004-01-01

    The progress of the magnetic resonance (MR) imaging in the cerebral stroke patients was remarkable, and it became possible to evaluate a brain perfusion or function. Here, we describe about the clinical application of the neuronal tracts and brain perfusion evaluation using 3.0 Tesla MR imaging. The subjects were patients with internal cerebral hemorrhage and major cerebral occlusive diseases. Three dimensional anisotropy contrast (3DAC) imaging and diffusion tensor imaging (DTI) were accepted to estimate the damages of neurnal tracts. Perfusion weighted images with the contrast medium were performed for a quantitative evaluation. The pyramidal tracts were depicted well with 3DAC imaging. Fractional anisotropy (FA) value generated from DTI can predict the outcome of the motor dysfunction in each patient at early stage. Cerebral blood volume calculated from perfusion weighted imaging (PWI) was correlated with and cerebral vascular reserve capacity. 3.0 Tesla MR imaging may develop in cerebral stroke patients in near future. (author)

  13. A mechanically tunable and efficient ceramic probe for MR-microscopy at 17 Tesla

    Science.gov (United States)

    Kurdjumov, Sergei; Glybovski, Stanislav; Hurshkainen, Anna; Webb, Andrew; Abdeddaim, Redha; Ciobanu, Luisa; Melchakova, Irina; Belov, Pavel

    2017-09-01

    In this contribution we propose and study numerically a new probe (radiofrequency coil) for magnetic resonance mi-croscopy in the field of 17T. The probe is based on two coupled donut resonators made of a high-permittivity and low-loss ceramics excited by a non-resonant inductively coupled loop attached to a coaxial cable. By full-wave numerical simulation it was shown that the probe can be precisely tuned to the Larmor frequency of protons (723 MHz) by adjusting a gap between the two resonators. Moreover, the impedance of the probe can be matched by varying the distance from one of the resonators to the loop. As a result, a compact and mechanically tunable resonant probe was demonstrated for 17 Tesla applications using no lumped capacitors for tuning and matching. The new probe was numerically compared to a conventional solenoidal probe showing better efficiency.

  14. Perforating arteries originating from the posterior communicating artery: a 7.0-Tesla MRI study

    Energy Technology Data Exchange (ETDEWEB)

    Conijn, Mandy M.A.; Hendrikse, Jeroen; Takahara, Taro; Mali, Willem P.T.M. [University Medical Center Utrecht, Department of Radiology (Hp E 01.132), P.O. Box 85500, Utrecht (Netherlands); Zwanenburg, Jaco J.M. [University Medical Center Utrecht, Image Sciences Institute, Utrecht (Netherlands); Geerlings, Mirjam I. [University Medical Center Utrecht, Julius Center for Health Sciences and Primary Care, Utrecht (Netherlands); Luijten, Peter R. [University Medical Center Utrecht, Department of Radiology (Hp E 01.132), P.O. Box 85500, Utrecht (Netherlands); University Medical Center Utrecht, Image Sciences Institute, Utrecht (Netherlands)

    2009-12-15

    The aim of this study was to investigate the ability of time-of-flight (TOF) magnetic resonance (MR) angiography at 7.0 Tesla to show the perforating branches of the posterior communicating artery (PCoA), and to investigate the presence of such visible perforating branches in relation to the size of the feeding PCoA. The secondary aim was to visualise and describe the anterior choroidal artery and the perforating branches of the P1-segment of posterior cerebral artery (P1). Forty-six healthy volunteers underwent TOF MR angiography at 7.0 Tesla. With 7.0-Tesla imaging, we visualised for the first time perforating arteries originating from the PCoA in vivo without the use of contrast agents. A perforating artery from the PCoA was found in a large proportion of the PCoAs (64%). The presence was associated with a larger diameter of the underlying PCoA (1.23 versus 1.06 mm, P = 0.03). The anterior choroidal artery was visible bilaterally in all participants. In 83% of all P1s, one or two perforating branches were visible. Non-invasive assessment of the perforating arteries of the PCoA together with the anterior choroidal artery and the perforating arteries of the P1 may increase our understanding of infarcts in the deep brain structures supplied by these arteries. (orig.)

  15. Perforating arteries originating from the posterior communicating artery: a 7.0-Tesla MRI study

    International Nuclear Information System (INIS)

    Conijn, Mandy M.A.; Hendrikse, Jeroen; Takahara, Taro; Mali, Willem P.T.M.; Zwanenburg, Jaco J.M.; Geerlings, Mirjam I.; Luijten, Peter R.

    2009-01-01

    The aim of this study was to investigate the ability of time-of-flight (TOF) magnetic resonance (MR) angiography at 7.0 Tesla to show the perforating branches of the posterior communicating artery (PCoA), and to investigate the presence of such visible perforating branches in relation to the size of the feeding PCoA. The secondary aim was to visualise and describe the anterior choroidal artery and the perforating branches of the P1-segment of posterior cerebral artery (P1). Forty-six healthy volunteers underwent TOF MR angiography at 7.0 Tesla. With 7.0-Tesla imaging, we visualised for the first time perforating arteries originating from the PCoA in vivo without the use of contrast agents. A perforating artery from the PCoA was found in a large proportion of the PCoAs (64%). The presence was associated with a larger diameter of the underlying PCoA (1.23 versus 1.06 mm, P = 0.03). The anterior choroidal artery was visible bilaterally in all participants. In 83% of all P1s, one or two perforating branches were visible. Non-invasive assessment of the perforating arteries of the PCoA together with the anterior choroidal artery and the perforating arteries of the P1 may increase our understanding of infarcts in the deep brain structures supplied by these arteries. (orig.)

  16. Perforating arteries originating from the posterior communicating artery: a 7.0-Tesla MRI study.

    Science.gov (United States)

    Conijn, Mandy M A; Hendrikse, Jeroen; Zwanenburg, Jaco J M; Takahara, Taro; Geerlings, Mirjam I; Mali, Willem P Th M; Luijten, Peter R

    2009-12-01

    The aim of this study was to investigate the ability of time-of-flight (TOF) magnetic resonance (MR) angiography at 7.0 Tesla to show the perforating branches of the posterior communicating artery (PCoA), and to investigate the presence of such visible perforating branches in relation to the size of the feeding PCoA. The secondary aim was to visualise and describe the anterior choroidal artery and the perforating branches of the P1-segment of posterior cerebral artery (P1). Forty-six healthy volunteers underwent TOF MR angiography at 7.0 Tesla. With 7.0-Tesla imaging, we visualised for the first time perforating arteries originating from the PCoA in vivo without the use of contrast agents. A perforating artery from the PCoA was found in a large proportion of the PCoAs (64%). The presence was associated with a larger diameter of the underlying PCoA (1.23 versus 1.06 mm, P = 0.03). The anterior choroidal artery was visible bilaterally in all participants. In 83% of all P1s, one or two perforating branches were visible. Non-invasive assessment of the perforating arteries of the PCoA together with the anterior choroidal artery and the perforating arteries of the P1 may increase our understanding of infarcts in the deep brain structures supplied by these arteries.

  17. Recent electron-cloud simulation results for the main damping rings of the NLC and TESLA linear colliders

    International Nuclear Information System (INIS)

    Pivi, M.; Raubenheimer, T.O.; Furman, M.A.

    2003-01-01

    In the beam pipe of the Main Damping Ring (MDR) of the Next Linear Collider (NLC), ionization of residual gases and secondary emission give rise to an electron-cloud which stabilizes to equilibrium after few bunch trains. In this paper, we present recent computer simulation results for the main features of the electron cloud at the NLC and preliminary simulation results for the TESLA main damping rings, obtained with the code POSINST that has been developed at LBNL, and lately in collaboration with SLAC, over the past 7 years. Possible remedies to mitigate the effect are also discussed. We have recently included the possibility to simulate different magnetic field configurations in our code including solenoid, quadrupole, sextupole and wiggler

  18. Technical cooperation on government base with developing countries in the field of atomic energy

    International Nuclear Information System (INIS)

    Hamabe, Yutaka

    1984-01-01

    Since the summer of the last year, the problems in the relation with developing countries have been actively discussed in the Atomic Energy Commission, Japan Atomic Industrial Forum Inc., and the Ministry of International Trade and Industry. As the background of this tendency, it is pointed out that Japanese nuclear industry has grown up to the level comparable with European and American counterparts and capable of advancing into the world market as the exporter of nuclear facilities, on the other hand, that Asian countries expect Japanese technical and economical power also in the field of atomic energy. In this report, the technical cooperation of the IAEA on funds, the dispatch of specialists, the supply of materials and training, the technical cooperation of Japanese International Cooperation Agency on the acceptance of trainees, the dispatch of specialists and others, and the fundamental way of thinking about the technical cooperation on government base are reported. It is very important to grasp the true needs of a partner country when a project is selected. In the cooperation, the effort of self-help by a developing country must be the major premise. (Kako, I.)

  19. 7.0 tesla MRI brain white matter atlas. 2. ed.

    International Nuclear Information System (INIS)

    Cho, Zang-Hee

    2015-01-01

    Depicts the visualization of brain white matter with the latest 7.0 T MRI and TDI techniques. Represents a useful addition to brain research and clinical settings, such as the Human Connectome Project. Contains a wealth of exquisitely detailed color images. The introduction of techniques that permit visualization of the human nervous system is one of the foremost advances in neuroscience and brain-related research. Among the most recent significant developments in this respect are ultra-high field MRI and the image post-processing technique known as track density imaging (TDI). It is these techniques (including super-resolution TDI) which represent the two major components of 7.0 Tesla MRI - Brain White Matter Atlas. This second edition of the atlas has been revised and updated to fully reflect current application of these technological advancements in order to visualize the nervous system and the brain with the finest resolution and sensitivity. Exquisitely detailed color images offer neuroscientists, neurologists, and neurosurgeons a superb resource that will be of value both for the purpose of research and for the treatment of common brain diseases such as Alzheimer's disease and multiple sclerosis.

  20. 7.0 tesla MRI brain white matter atlas. 2. ed.

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Zang-Hee (ed.) [Gachon Univ., Incheon (Korea, Republic of). Neuroscience Research Institute

    2015-04-01

    Depicts the visualization of brain white matter with the latest 7.0 T MRI and TDI techniques. Represents a useful addition to brain research and clinical settings, such as the Human Connectome Project. Contains a wealth of exquisitely detailed color images. The introduction of techniques that permit visualization of the human nervous system is one of the foremost advances in neuroscience and brain-related research. Among the most recent significant developments in this respect are ultra-high field MRI and the image post-processing technique known as track density imaging (TDI). It is these techniques (including super-resolution TDI) which represent the two major components of 7.0 Tesla MRI - Brain White Matter Atlas. This second edition of the atlas has been revised and updated to fully reflect current application of these technological advancements in order to visualize the nervous system and the brain with the finest resolution and sensitivity. Exquisitely detailed color images offer neuroscientists, neurologists, and neurosurgeons a superb resource that will be of value both for the purpose of research and for the treatment of common brain diseases such as Alzheimer's disease and multiple sclerosis.

  1. Occipital cortical proton MRS at 4 Tesla in human moderate MDMA polydrug users.

    Science.gov (United States)

    Cowan, Ronald L; Bolo, Nicolas R; Dietrich, Mary; Haga, Erica; Lukas, Scott E; Renshaw, Perry F

    2007-08-15

    The recreational drug MDMA (3,4, methylenedioxymethamphetamine; sold under the street name of Ecstasy) is toxic to serotonergic axons in some animal models of MDMA administration. In humans, MDMA use is associated with alterations in markers of brain function that are pronounced in occipital cortex. Among neuroimaging methods, magnetic resonance spectroscopy (MRS) studies of brain metabolites N-acetylaspartate (NAA) and myoinositol (MI) at a field strength of 1.5 Tesla (T) reveal inconsistent results in MDMA users. Because higher field strength proton MRS has theoretical advantages over lower field strengths, we used proton MRS at 4.0 T to study absolute concentrations of occipital cortical NAA and MI in a cohort of moderate MDMA users (n=9) versus non-MDMA using (n=7) controls. Mean NAA in non-MDMA users was 10.47 mM (+/-2.51), versus 9.83 mM (+/-1.94) in MDMA users. Mean MI in non-MDMA users was 7.43 mM (+/-.68), versus 6.57 mM (+/-1.59) in MDMA users. There were no statistical differences in absolute metabolite levels for NAA and MI in occipital cortex of MDMA users and controls. These findings are not supportive of MDMA-induced alterations in NAA or MI levels in this small sample of moderate MDMA users. Limitations to this study suggest caution in the interpretation of these results.

  2. 3 Tesla MRI-negative focal epilepsies: Presurgical evaluation, postoperative outcome and predictive factors.

    Science.gov (United States)

    Kogias, Evangelos; Klingler, Jan-Helge; Urbach, Horst; Scheiwe, Christian; Schmeiser, Barbara; Doostkam, Soroush; Zentner, Josef; Altenmüller, Dirk-Matthias

    2017-12-01

    To investigate presurgical diagnostic modalities, clinical and seizure outcome as well as predictive factors after resective epilepsy surgery in 3 Tesla MRI-negative focal epilepsies. This retrospective study comprises 26 patients (11 males/15 females, mean age 34±12years, range 13-50 years) with 3 Tesla MRI-negative focal epilepsies who underwent resective epilepsy surgery. Non-invasive and invasive presurgical diagnostic modalities, type and localization of resection, clinical and epileptological outcome with a minimum follow-up of 1year (range 1-11 years, mean 2.5±2.3years) after surgery as well as outcome predictors were evaluated. All patients underwent invasive video-EEG monitoring after implantation of intracerebral depth and/or subdural electrodes. Ten patients received temporal and 16 extratemporal or multilobar (n=4) resections. There was no perioperative death or permanent morbidity. Overall, 12 of 26 patients (46%) were completely seizure-free (Engel IA) and 65% had a favorable outcome (Engel I-II). In particular, seizure-free ratio was 40% in the temporal and 50% in the extratemporal group. In the temporal group, long duration of epilepsy correlated with poor seizure outcome, whereas congruent unilateral FDG-PET hypometabolism correlated with a favorable outcome. In almost two thirds of temporal and extratemporal epilepsies defined as "non-lesional" by 3 Tesla MRI criteria, a favorable postoperative seizure outcome (Engel I-II) can be achieved with accurate multimodal presurgical evaluation including intracranial EEG recordings. In the temporal group, most favorable results were obtained when FDG-PET displayed congruent unilateral hypometabolism. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Value of 3 Tesla diffusion-weighted magnetic resonance imaging for assessing liver fibrosis.

    Science.gov (United States)

    Papalavrentios, Lavrentios; Sinakos, Emmanouil; Chourmouzi, Danai; Hytiroglou, Prodromos; Drevelegas, Konstantinos; Constantinides, Manos; Drevelegas, Antonios; Talwalkar, Jayant; Akriviadis, Evangelos

    2015-01-01

    Limited data are available regarding the role of magnetic resonance imaging (MRI), particularly the new generation 3 Tesla technology, and especially diffusion-weighted imaging (DWI) in predicting liver fibrosis. The aim of our pilot study was to assess the clinical performance of the apparent diffusion coefficient (ADC) of liver parenchyma for the assessment of liver fibrosis in patients with non-alcoholic fatty liver disease (NAFLD). 18 patients with biopsy-proven NAFLD underwent DWI with 3 Tesla MRI. DWI was performed with single-shot echo-planar technique at b values of 0-500 and 0-1000 s/mm 2 . ADC was measured in four locations in the liver and the mean ADC value was used for analysis. Staging of fibrosis was performed according to the METAVIR system. The median age of patients was 52 years (range 23-73). The distribution of patients in different fibrosis stages was: 0 (n=1), 1 (n=7), 2 (n=1), 3 (n=5), 4 (n=4). Fibrosis stage was poorly associated with ADC at b value of 0-500 s/mm 2 (r= -0.30, P=0.27). However it was significantly associated with ADC at b value of 0-1000 s/mm 2 (r= -0.57, P=0.01). For this b value (0-1000 s/mm 2 ) the area under receiver-operating characteristic curve was 0.93 for fibrosis stage ≥3 and the optimal ADC cut-off value was 1.16 ×10 -3 mm 2 /s. 3 Tesla DWI can possibly predict the presence of advanced fibrosis in patients with NAFLD.

  4. On the possibility of a normal conducting photo-injector for Tesla

    International Nuclear Information System (INIS)

    Travier, C.

    1992-12-01

    The possibility of using a normal conducting photo-injector for the TESLA linear collider is investigated. It is shown that the 8 nC,3 ps bunch can be produced with a normalized emittance less than 100 Π mm mrad. The generation of the train depends on the feasibility of the laser which has to be looked at more carefully

  5. [Electric traction magnetic fields of ultra-low frequency as an occupational risk factor of ischemic heart disease].

    Science.gov (United States)

    Ptitsyna, N G; Kudrin, V A; Villorezi, D; Kopytenko, Iu A; Tiasto, M I; Kopytenko, E A; Bochko, V A; Iuchchi, N

    1996-01-01

    The study was inspired by earlier results that displayed influence of variable natural geomagnetic field (0.005-10 Hz range-ultra-low frequencies) on circulatory system, indicated possible correlation between industrial ultra-low frequency fields and prevalence of myocardial infarction. The authors conducted unique measurements of ultra-low frequency fields produced by electric engines. The results were compared with data on morbidity among railway transport workers. The findings are that level of magnetic variations in electric locomotive cabin can exceed 280 micro Tesla, whereas that in car sections reaches 50 micro Tesla. Occurrence of coronary heart disease among the locomotive operators appeared to be 2.0 + 0.2 times higher than that among the car section operators. Higher risk of coronary heart disease in the locomotive operators is associated with their increased occupational magnetic load.

  6. Ability of preoperative 3.0-Tesla magnetic resonance imaging to predict the absence of side-specific extracapsular extension of prostate cancer.

    Science.gov (United States)

    Hara, Tomohiko; Nakanishi, Hiroyuki; Nakagawa, Tohru; Komiyama, Motokiyo; Kawahara, Takashi; Manabe, Tomoko; Miyake, Mototaka; Arai, Eri; Kanai, Yae; Fujimoto, Hiroyuki

    2013-10-01

    Recent studies have shown an improvement in prostate cancer diagnosis with the use of 3.0-Tesla magnetic resonance imaging. We retrospectively assessed the ability of this imaging technique to predict side-specific extracapsular extension of prostate cancer. From October 2007 to August 2011, prostatectomy was carried out in 396 patients after preoperative 3.0-Tesla magnetic resonance imaging. Among these, 132 (primary sample) and 134 patients (validation sample) underwent 12-core prostate biopsy at the National Cancer Center Hospital of Tokyo, Japan, and at other institutions, respectively. In the primary dataset, univariate and multivariate analyses were carried out to predict side-specific extracapsular extension using variables determined preoperatively, including 3.0-Tesla magnetic resonance imaging findings (T2-weighted and diffusion-weighted imaging). A prediction model was then constructed and applied to the validation study sample. Multivariate analysis identified four significant independent predictors (P Tesla diffusion-weighted magnetic resonance imaging findings, ≥2 positive biopsy cores on each side and a maximum percentage of positive cores ≥31% on each side. The negative predictive value was 93.9% in the combination model with these four predictors, meanwhile the positive predictive value was 33.8%. Good reproducibility of these four significant predictors and the combination model was observed in the validation study sample. The side-specific extracapsular extension prediction by the biopsy Gleason score and factors associated with tumor location, including a positive 3.0-Tesla diffusion-weighted magnetic resonance imaging finding, have a high negative predictive value, but a low positive predictive value. © 2013 The Japanese Urological Association.

  7. Magnetic resonance imaging investigation of the bone conduction implant - a pilot study at 1.5 Tesla.

    Science.gov (United States)

    Jansson, Karl-Johan Fredén; Håkansson, Bo; Reinfeldt, Sabine; Rigato, Cristina; Eeg-Olofsson, Måns

    2015-01-01

    The objective of this pilot study was to investigate if an active bone conduction implant (BCI) used in an ongoing clinical study withstands magnetic resonance imaging (MRI) of 1.5 Tesla. In particular, the MRI effects on maximum power output (MPO), total harmonic distortion (THD), and demagnetization were investigated. Implant activation and image artifacts were also evaluated. One implant was placed on the head of a test person at the position corresponding to the normal position of an implanted BCI and applied with a static pressure using a bandage and scanned in a 1.5 Tesla MRI camera. Scanning was performed both with and without the implant, in three orthogonal planes, and for one spin-echo and one gradient-echo pulse sequence. Implant functionality was verified in-between the scans using an audio processor programmed to generate a sequence of tones when attached to the implant. Objective verification was also carried out by measuring MPO and THD on a skull simulator as well as retention force, before and after MRI. It was found that the exposure of 1.5 Tesla MRI only had a minor effect on the MPO, ie, it decreased over all frequencies with an average of 1.1±2.1 dB. The THD remained unchanged above 300 Hz and was increased only at lower frequencies. The retention magnet was demagnetized by 5%. The maximum image artifacts reached a distance of 9 and 10 cm from the implant in the coronal plane for the spin-echo and the gradient-echo sequence, respectively. The test person reported no MRI induced sound from the implant. This pilot study indicates that the present BCI may withstand 1.5 Tesla MRI with only minor effects on its performance. No MRI induced sound was reported, but the head image was highly distorted near the implant.

  8. Monitoring the electron beam position at the TESLA test facility free electron laser

    Energy Technology Data Exchange (ETDEWEB)

    Kamps, T

    2000-06-14

    The operation of a free electron laser working in the Self Amplified Spontaneous Emission mode (SASE FEL) requires the electron trajectory to be aligned with very high precision in overlap with the photon beam. In order to ensure this overlap, one module of the SASE FEL undulator at the TESLA Test Facility (TTF) is equipped with a new type of waveguide beam position monitor (BPM). Four waveguides are arranged symmetrically around the beam pipe, each channel couples through a small slot to the electromagnetic beam field. The induced signal depends on the beam intensity and on the transverse beam position in terms of beam-to-slot distance. With four slot--waveguide combinations a linear position sensitive signal can be achieved, which is independent of the beam intensity. The signals transduced by the slots are transferred by ridged waveguides through an impedance matching stage into a narrowband receiver tuned to 12 GHz. The present thesis describes design, tests, and implementation of this new type of BPM. (orig.)

  9. Proceedings from the technical workshop on near-field performance assessment for high-level waste

    International Nuclear Information System (INIS)

    Sellin, P.; Apted, M.; Gago, J.

    1991-12-01

    This report contains the proceedings of 'Technical workshop of near-filed performance assessment for high-level waste' held in Madrid October 15-17, 1990. It includes the invited presentations and summaries of the scientific discussions. The workshop covered several topics: * post-emplacement environment, * benchmarking of computer codes, * glass release, * spent-fuel release, * radionuclide solubility, * near-field transport processes, * coupled processes in the near-field, * integrated assessments, * sensitivity analyses and validation. There was an invited presentation on each topic followed by an extensive discussion. One of the points highlighted in the closing discussion of the workshop was the need for international cooperation in the field of near-field performance assessment. The general opinion was that this was best achieved in smaller groups discussing specific questions. (au) Separate abstracts were prepared for 9 papers in this volume

  10. Magnetic field measurements of the superEBIS superconducting magnet

    International Nuclear Information System (INIS)

    Herschcovitch, A.; Kponou, A.; Clipperton, R.; Hensel, W.; Usack, F.

    1994-01-01

    SuperEBIS was designed to have a solenoidal magnetic field of a 5 Tesla strength with a 120 cm long bore. The field was specified to be straight within 1 part in 10000 within the bore, and uniform to within 1 part in 1000 within the central 90 cm. Magnetic field measurements were performed with a computerized magnetic field measuring setup that was borrowed from W. Sampson's group. A preliminary test was made of a scheme to determine if the magnetic and mechanical axes of the solenoid coincided, and, if not, by how much

  11. Reproducibility of 3.0 Tesla Magnetic Resonance Spectroscopy for Measuring Hepatic Fat Content

    NARCIS (Netherlands)

    van Werven, Jochem R.; Hoogduin, Johannes M.; Nederveen, Aart J.; van Vliet, Andre A.; Wajs, Ewa; Vandenberk, Petra; Stroes, Erik S. G.; Stoker, Jaap

    Purpose: To investigate reproducibility of proton magnetic resonance spectroscopy (H-1-MRS) to measure hepatic triglyceride content (HTGC). Materials and Methods: In 24 subjects, HTGC was evaluated using H-1-MRS at 3.0 Tesla. We studied "between-weeks" reproducibility and reproducibility of H-1-MRS

  12. Electrically Injected Polariton Lasing from a GaAs-Based Microcavity under Magnetic Field

    KAUST Repository

    Bhattacharya, Pallab; Das, Ayan; Jankowski, Marc; Bhowmick, Sishir; Lee, Chi-Sen; Jahangir, Shafat

    2012-01-01

    Suppression of relaxation bottleneck and subsequent polariton lasing is observed in a GaAs-based microcavity under the application of a magnetic field. The threshold injection current density is 0.32 A/cm2 at 7 Tesla.

  13. 7 Tesla proton magnetic resonance spectroscopic imaging in adult X-linked adrenoleukodystrophy

    Science.gov (United States)

    Ratai, Eva; Kok, Trina; Wiggins, Christopher; Wiggins, Graham; Grant, Ellen; Gagoski, Borjan; O'Neill, Gilmore; Adalsteinsson, Elfar; Eichler, Florian

    2010-01-01

    Background Adult patients with X-linked adrenoleukodystrophy (X-ALD) remain at risk for progressive neurological deterioration. Phenotypes vary in their pathology, ranging from axonal degeneration to inflammatory demyelination. The severity of symptoms is poorly explained by conventional imaging. Objective To test the hypothesis that neurochemistry in normal appearing brain differs among adult phenotypes of X-ALD, and that neurochemical changes correlate with the severity of symptoms. Patients and Methods Using a 7 Tesla scanner we performed structural and proton MRSI in 13 adult patients with X-ALD, including 4 patients with adult cerebral ALD (ACALD), 5 with adrenomyeloneuropathy (AMN) and 4 female heterozygotes. Studies were also performed in nine healthy controls. Results Among adult X-ALD phenotypes, MI/Cr was 46% higher and Cho/Cr 21% higher in normal appearing white matter of ACALD compared to AMN (p Tesla proton MRSI reveals differences in the neurochemistry of ACALD but is unable to distinguish AMN from female heterozygotes. MI/Cr correlates with the severity of the symptoms and may be a meaningful biomarker in adult X-ALD. PMID:19001168

  14. Echo-Planar Imaging for a 9.4 Tesla Vertical-Bore Superconducting Magnet Using an Unshielded Gradient Coil.

    Science.gov (United States)

    Kodama, Nao; Kose, Katsumi

    2016-10-11

    Echo-planar imaging (EPI) sequences were developed for a 9.4 Tesla vertical standard bore (~54 mm) superconducting magnet using an unshielded gradient coil optimized for live mice imaging and a data correction technique with reference scans. Because EPI requires fast switching of intense magnetic field gradients, eddy currents were induced in the surrounding metallic materials, e.g., the room temperature bore, and this produced serious artifacts on the EPI images. We solved the problem using an unshielded gradient coil set of proper size (outer diameter = 39 mm, inner diameter = 32 mm) with time control of the current rise and reference scans. The obtained EPI images of a phantom and a plant sample were almost artifact-free and demonstrated the promise of our approach.

  15. Echo-Planar Imaging for a 9.4 Tesla Vertical-Bore Superconducting Magnet Using an Unshielded Gradient Coil

    Science.gov (United States)

    KODAMA, Nao; KOSE, Katsumi

    2016-01-01

    Echo-planar imaging (EPI) sequences were developed for a 9.4 Tesla vertical standard bore (∼54 mm) superconducting magnet using an unshielded gradient coil optimized for live mice imaging and a data correction technique with reference scans. Because EPI requires fast switching of intense magnetic field gradients, eddy currents were induced in the surrounding metallic materials, e.g., the room temperature bore, and this produced serious artifacts on the EPI images. We solved the problem using an unshielded gradient coil set of proper size (outer diameter = 39 mm, inner diameter = 32 mm) with time control of the current rise and reference scans. The obtained EPI images of a phantom and a plant sample were almost artifact-free and demonstrated the promise of our approach. PMID:27001398

  16. Diseño y construcción de una bobina Tesla

    OpenAIRE

    Pérez de Obanos Francés, Eduardo

    2010-01-01

    El objetivo de este proyecto es diseñar y construir una bobina Tesla de tamaño medio y observar las descargas emitidas desde el terminal superior. Además se realizarán una serie de pruebas para comprobar si los resultados obtenidos en esta experiencia se asemejan a los de estudios anteriores. Ingeniería Técnica Industrial Industria Ingeniaritza Teknikoa

  17. 40-Tesla pulsed-field cryomagnet for single crystal neutron diffraction

    Science.gov (United States)

    Duc, F.; Tonon, X.; Billette, J.; Rollet, B.; Knafo, W.; Bourdarot, F.; Béard, J.; Mantegazza, F.; Longuet, B.; Lorenzo, J. E.; Lelièvre-Berna, E.; Frings, P.; Regnault, L.-P.

    2018-05-01

    We present the first long-duration and high duty cycle 40-T pulsed-field cryomagnet addressed to single crystal neutron diffraction experiments at temperatures down to 2 K. The magnet produces a horizontal field in a bi-conical geometry, ±15° and ±30° upstream and downstream of the sample, respectively. Using a 1.15 MJ mobile generator, magnetic field pulses of 100 ms length are generated in the magnet, with a rise time of 23 ms and a repetition rate of 6-7 pulses per hour at 40 T. The setup was validated for neutron diffraction on the CEA-CRG three-axis spectrometer IN22 at the Institut Laue Langevin.

  18. MR imaging at 0.5 Tesla with FLAIR sequence in the diagnosis of acute subarachnoid hemorrhage

    International Nuclear Information System (INIS)

    Kopsa, W.; Leitner, H.; Tscholakoff, D.; Perneczky, G.

    1998-01-01

    Purpose: Evaluation of MR imaging in patients with acute subarachnoid hemorrhage (SAH) at 0.5 Tesla using the FLAIR (Fluid Attenuated Inversion Recovery) sequenze. Additionally, the value of MR angiographie (MRA) in the diagnosis of intracranial aneurysms was assessed. Materials and Methods: 19 patients with suspected acute SAH were included in this study. MR imaging was performed using an axial FLAIR sequence and axial T 1 , T 2 and PD weighted sequences. In 16 patients an additional MRA (3D-TOF) was performed. 10 patients without SAH were examined as a control group. At the end of the study the 29 MR examinations were randomised and the images were read by two experienced radiologists; subsequently a consensus interpretation was made. Results: In 16 patients an acute SAH was verified with the FLAIR sequence, in 13 cases the origin of hemorrhage was found during surgery. In the consensus interpretation of the MR images all cases were diagnosed properly. 12 of the 16 MRA studies were of diagnostic quality, but only 6 cases were interpreted correctly. Conclusion: The FLAIR sequence at 0.5 Tesla proved effective in the diagnosis of acute SAH. MRA at 0.5 Tesla failed in the detection of intracranial aneurysms. (orig.) [de

  19. Pulsatility of Lenticulostriate Arteries Assessed by 7 Tesla Flow MRI-Measurement, Reproducibility, and Applicability to Aging Effect.

    Science.gov (United States)

    Schnerr, Roald S; Jansen, Jacobus F A; Uludag, Kamil; Hofman, Paul A M; Wildberger, Joachim E; van Oostenbrugge, Robert J; Backes, Walter H

    2017-01-01

    Characterization of flow properties in cerebral arteries with 1.5 and 3 Tesla MRI is usually limited to large cerebral arteries and difficult to evaluate in the small perforating arteries due to insufficient spatial resolution. In this study, we assessed the feasibility to measure blood flow waveforms in the small lenticulostriate arteries with 7 Tesla velocity-sensitive MRI. The middle cerebral artery was included as reference. Imaging was performed in five young and five old healthy volunteers. Flow was calculated by integrating time-varying velocity values over the vascular cross-section. MRI acquisitions were performed twice in each subject to determine reproducibility. From the flow waveforms, the pulsatility index and damping factor were deduced. Reproducibility values, in terms of the intraclass correlation coefficients, were found to be good to excellent. Measured pulsatility index of the lenticulostriate arteries significantly increased and damping factor significantly decreased with age. In conclusion, we demonstrate that blood flow through the lenticostriate arteries can be precisely measured using 7 Tesla MRI and reveal effects of arterial stiffness due to aging. These findings hold promise to provide relevant insights into the pathologies involving perforating cerebral arteries.

  20. Is the Ellipsoid Formula the New Standard for 3-Tesla MRI Prostate Volume Calculation without Endorectal Coil?

    Science.gov (United States)

    Haas, Matthias; Günzel, Karsten; Miller, Kurt; Hamm, Bernd; Cash, Hannes; Asbach, Patrick

    2017-01-01

    Prostate volume in multiparametric MRI (mpMRI) is of clinical importance. For 3-Tesla mpMRI without endorectal coil, there is no distinctive standard for volume calculation. We tested the accuracy of the ellipsoid formula with planimetric volume measurements as reference and investigated the correlation of gland volume and cancer detection rate on MRI/ultrasound (MRI/US) fusion-guided biopsy. One hundred forty-three patients with findings on 3-Tesla mpMRI suspicious of cancer and subsequent MRI/US fusion-guided targeted biopsy and additional systematic biopsy were analyzed. T2-weighted images were used for measuring the prostate diameters and for planimetric volume measurement by a segmentation software. Planimetric and calculated prostate volumes were compared with clinical data. The median prostate volume was 48.1 ml (interquartile range (IQR) 36.9-62.1 ml). Volume calculated by the ellipsoid formula showed a strong concordance with planimetric volume, with a tendency to underestimate prostate volume (median volume 43.1 ml (IQR 31.2-58.8 ml); r = 0.903, p Tesla mpMRI without endorectal coil. It allows a fast, valid volume calculation in prostate MRI datasets. © 2016 S. Karger AG, Basel.

  1. Magnet Design and Analysis of a 40 Tesla Long Pulse System Energized by a Battery Bank

    Science.gov (United States)

    Lv, Y. L.; Peng, T.; Wang, G. B.; Ding, T. H.; Han, X. T.; Pan, Y.; Li, L.

    2013-03-01

    A 40 tesla long pulse magnet and a battery bank as the power supply have been designed. This is now under construction at the Wuhan National High Magnetic Field Center. The 22 mm bore magnet will generate smooth pulses with duration 1 s and rise time 0.5 s. The battery bank consists of 945 12V/200 Ah lead-acid battery cells. The magnet and battery bank were optimized by codes developed in-house and by ANSYS. The coil was made from soft copper with internal reinforcement by fiber-epoxy composite; it is divided into two sections connected in series. The inner section consists of helix coils with each layer reinforced by Zylon composite. The outer section will be wound from copper sheet and externally reinforced by carbon fiber composite.

  2. Development and manufacturing of a Nb$_{3}$Sn quadrupole magnet Model at CEA/Saclay for TESLA Interaction Region

    CERN Document Server

    Durante, Maria; Fratini, M; Leboeuf, D; Segreti, M; Védrine, Pierre; 10.1109/TASC.2004.829129

    2004-01-01

    One possible application of Nb/sub 3/Sn, whose superconducting properties far exceed those of NbTi, is the fabrication of short and powerful quadrupole magnets for the interaction regions of large particle accelerators. In some projects, as in the future linear collider TESLA, the quadrupole magnets are inside the detector solenoid and must operate in its background field. This situation gives singular Lorentz force distribution in the ends of the magnet. To learn about Nb/sub 3/Sn technology, evaluate fabrication techniques and test the interaction with a solenoidal field, DAPNIA /SACM at CEA/Saclay has started the manufacturing of a 1-m-long, 56- mm-single-aperture quadrupole magnet model. The model relies on the same coil geometry as the LHC arc quadrupole magnets, but has no iron yoke. It will produce a nominal field gradient of 211 T/m at 11,870 A. The coils are wound from Rutherford-type cables insulated with glass fiber tape, before being heat-treated and vacuum-impregnated with epoxy resin. Laminated,...

  3. 76 FR 31823 - Technical Amendment to List of User Fee Airports: Addition of Dallas Love Field Municipal Airport...

    Science.gov (United States)

    2011-06-02

    ...] Technical Amendment to List of User Fee Airports: Addition of Dallas Love Field Municipal Airport, Dallas... fee airport designation for Dallas Love Field Municipal Airport, in Dallas, Texas. User fee airports.... Generally, the type of airport that would seek designation as a user fee airport would be one at which a...

  4. Single-row vs. double-row arthroscopic rotator cuff repair: clinical and 3 Tesla MR arthrography results

    Science.gov (United States)

    2013-01-01

    Background Arthroscopic rotator cuff repair has become popular in the last few years because it avoids large skin incisions and deltoid detachment and dysfunction. Earlier arthroscopic single-row (SR) repair methods achieved only partial restoration of the original footprint of the tendons of the rotator cuff, while double-row (DR) repair methods presented many biomechanical advantages and higher rates of tendon-to-bone healing. However, DR repair failed to demonstrate better clinical results than SR repair in clinical trials. MR imaging at 3 Tesla, especially with intra-articular contrast medium (MRA), showed a better diagnostic performance than 1.5 Tesla in the musculoskeletal setting. The objective of this study was to retrospectively evaluate the clinical and 3 Tesla MRA results in two groups of patients operated on for a medium-sized full-thickness rotator cuff tear with two different techniques. Methods The first group consisted of 20 patients operated on with the SR technique; the second group consisted of 20 patients operated on with the DR technique. All patients were evaluated at a minimum of 3 years after surgery. The primary end point was the re-tear rate at 3 Tesla MRA. The secondary end points were the Constant-Murley Scale (CMS), the Simple Shoulder Test (SST) scores, surgical time and implant expense. Results The mean follow-up was 40 months in the SR group and 38.9 months in the DR group. The mean postoperative CMS was 70 in the SR group and 68 in the DR group. The mean SST score was 9.4 in the SR group and 10.1 in the DR group. The re-tear rate was 60% in the SR group and 25% in the DR group. Leakage of the contrast medium was observed in all patients. Conclusions To the best of our knowledge, this is the first report on 3 Tesla MRA in the evaluation of two different techniques of rotator cuff repair. DR repair resulted in a statistically significant lower re-tear rate, with longer surgical time and higher implant expense, despite no

  5. Single-row vs. double-row arthroscopic rotator cuff repair: clinical and 3 Tesla MR arthrography results

    Directory of Open Access Journals (Sweden)

    Tudisco Cosimo

    2013-01-01

    Full Text Available Abstract Background Arthroscopic rotator cuff repair has become popular in the last few years because it avoids large skin incisions and deltoid detachment and dysfunction. Earlier arthroscopic single-row (SR repair methods achieved only partial restoration of the original footprint of the tendons of the rotator cuff, while double-row (DR repair methods presented many biomechanical advantages and higher rates of tendon-to-bone healing. However, DR repair failed to demonstrate better clinical results than SR repair in clinical trials. MR imaging at 3 Tesla, especially with intra-articular contrast medium (MRA, showed a better diagnostic performance than 1.5 Tesla in the musculoskeletal setting. The objective of this study was to retrospectively evaluate the clinical and 3 Tesla MRA results in two groups of patients operated on for a medium-sized full-thickness rotator cuff tear with two different techniques. Methods The first group consisted of 20 patients operated on with the SR technique; the second group consisted of 20 patients operated on with the DR technique. All patients were evaluated at a minimum of 3 years after surgery. The primary end point was the re-tear rate at 3 Tesla MRA. The secondary end points were the Constant-Murley Scale (CMS, the Simple Shoulder Test (SST scores, surgical time and implant expense. Results The mean follow-up was 40 months in the SR group and 38.9 months in the DR group. The mean postoperative CMS was 70 in the SR group and 68 in the DR group. The mean SST score was 9.4 in the SR group and 10.1 in the DR group. The re-tear rate was 60% in the SR group and 25% in the DR group. Leakage of the contrast medium was observed in all patients. Conclusions To the best of our knowledge, this is the first report on 3 Tesla MRA in the evaluation of two different techniques of rotator cuff repair. DR repair resulted in a statistically significant lower re-tear rate, with longer surgical time and higher implant

  6. Single-row vs. double-row arthroscopic rotator cuff repair: clinical and 3 Tesla MR arthrography results.

    Science.gov (United States)

    Tudisco, Cosimo; Bisicchia, Salvatore; Savarese, Eugenio; Fiori, Roberto; Bartolucci, Dario A; Masala, Salvatore; Simonetti, Giovanni

    2013-01-27

    Arthroscopic rotator cuff repair has become popular in the last few years because it avoids large skin incisions and deltoid detachment and dysfunction. Earlier arthroscopic single-row (SR) repair methods achieved only partial restoration of the original footprint of the tendons of the rotator cuff, while double-row (DR) repair methods presented many biomechanical advantages and higher rates of tendon-to-bone healing. However, DR repair failed to demonstrate better clinical results than SR repair in clinical trials. MR imaging at 3 Tesla, especially with intra-articular contrast medium (MRA), showed a better diagnostic performance than 1.5 Tesla in the musculoskeletal setting. The objective of this study was to retrospectively evaluate the clinical and 3 Tesla MRA results in two groups of patients operated on for a medium-sized full-thickness rotator cuff tear with two different techniques. The first group consisted of 20 patients operated on with the SR technique; the second group consisted of 20 patients operated on with the DR technique. All patients were evaluated at a minimum of 3 years after surgery. The primary end point was the re-tear rate at 3 Tesla MRA. The secondary end points were the Constant-Murley Scale (CMS), the Simple Shoulder Test (SST) scores, surgical time and implant expense. The mean follow-up was 40 months in the SR group and 38.9 months in the DR group. The mean postoperative CMS was 70 in the SR group and 68 in the DR group. The mean SST score was 9.4 in the SR group and 10.1 in the DR group. The re-tear rate was 60% in the SR group and 25% in the DR group. Leakage of the contrast medium was observed in all patients. To the best of our knowledge, this is the first report on 3 Tesla MRA in the evaluation of two different techniques of rotator cuff repair. DR repair resulted in a statistically significant lower re-tear rate, with longer surgical time and higher implant expense, despite no difference in clinical outcomes. We think that

  7. PLACD-7T Study: Atherosclerotic Carotid Plaque Components Correlated with Cerebral Damage at 7 Tesla Magnetic Resonance Imaging.

    Science.gov (United States)

    den Hartog, A G; Bovens, S M; Koning, W; Hendrikse, J; Pasterkamp, G; Moll, F L; de Borst, G J

    2011-02-01

    In patients with carotid artery stenosis histological plaque composition is associated with plaque stability and with presenting symptomatology. Preferentially, plaque vulnerability should be taken into account in pre-operative work-up of patients with severe carotid artery stenosis. However, currently no appropriate and conclusive (non-) invasive technique to differentiate between the high and low risk carotid artery plaque in vivo is available. We propose that 7 Tesla human high resolution MRI scanning will visualize carotid plaque characteristics more precisely and will enable correlation of these specific components with cerebral damage. The aim of the PlaCD-7T study is 1: to correlate 7T imaging with carotid plaque histology (gold standard); and 2: to correlate plaque characteristics with cerebral damage ((clinically silent) cerebral (micro) infarcts or bleeds) on 7 Tesla high resolution (HR) MRI. We propose a single center prospective study for either symptomatic or asymptomatic patients with haemodynamic significant (70%) stenosis of at least one of the carotid arteries. The Athero-Express (AE) biobank histological analysis will be derived according to standard protocol. Patients included in the AE and our prospective study will undergo a pre-operative 7 Tesla HR-MRI scan of both the head and neck area. We hypothesize that the 7 Tesla MRI scanner will allow early identification of high risk carotid plaques being associated with micro infarcted cerebral areas, and will thus be able to identify patients with a high risk of periprocedural stroke, by identification of surrogate measures of increased cardiovascular risk.

  8. PLACD-7T Study: Atherosclerotic Carotid Plaque Components Correlated with Cerebral Damage at 7 Tesla Magnetic Resonance Imaging

    Science.gov (United States)

    den Hartog, A.G; Bovens, S.M; Koning, W; Hendrikse, J; Pasterkamp, G; Moll, F.L; de Borst, G.J

    2011-01-01

    Introduction: In patients with carotid artery stenosis histological plaque composition is associated with plaque stability and with presenting symptomatology. Preferentially, plaque vulnerability should be taken into account in pre-operative work-up of patients with severe carotid artery stenosis. However, currently no appropriate and conclusive (non-) invasive technique to differentiate between the high and low risk carotid artery plaque in vivo is available. We propose that 7 Tesla human high resolution MRI scanning will visualize carotid plaque characteristics more precisely and will enable correlation of these specific components with cerebral damage. Study objective: The aim of the PlaCD-7T study is 1: to correlate 7T imaging with carotid plaque histology (gold standard); and 2: to correlate plaque characteristics with cerebral damage ((clinically silent) cerebral (micro) infarcts or bleeds) on 7 Tesla high resolution (HR) MRI. Design: We propose a single center prospective study for either symptomatic or asymptomatic patients with haemodynamic significant (70%) stenosis of at least one of the carotid arteries. The Athero-Express (AE) biobank histological analysis will be derived according to standard protocol. Patients included in the AE and our prospective study will undergo a pre-operative 7 Tesla HR-MRI scan of both the head and neck area. Discussion: We hypothesize that the 7 Tesla MRI scanner will allow early identification of high risk carotid plaques being associated with micro infarcted cerebral areas, and will thus be able to identify patients with a high risk of periprocedural stroke, by identification of surrogate measures of increased cardiovascular risk. PMID:22294972

  9. Interventional MR imaging: Clinical results obtained with a 1.5 Tesla system

    International Nuclear Information System (INIS)

    Adam, G.; Guenther, R.W.

    1997-01-01

    The clinical feasibility of using interventional examination techniques was tested with an equipment combining fluoroscopy and MR imaging. This hybrid system showed to be of advantage in a great number of interventional examinations. The 1.5 Tesla magnet proved to be superior to open MR scanning systems in terms of image quality and scanning times. (orig.) [de

  10. Time-resolved magnetic resonance angiography (MRA) at 3.0 Tesla for evaluation of hemodynamic characteristics of vascular malformations: description of distinct subgroups.

    Science.gov (United States)

    Hammer, Simone; Uller, Wibke; Manger, Florentine; Fellner, Claudia; Zeman, Florian; Wohlgemuth, Walter A

    2017-01-01

    Quantitative evaluation of hemodynamic characteristics of arteriovenous and venous malformations using time-resolved magnetic resonance angiography (MRA) at 3.0 Tesla. Time-resolved MRA with interleaved stochastic trajectories (TWIST) at 3.0 Tesla was studied in 83 consecutive patients with venous malformations (VM) and arteriovenous malformations (AVM). Enhancement characteristics were calculated as percentage increase of signal intensity above baseline over time. Maximum percentage signal intensity increase (signal max ), time intervals between onset of arterial enhancement and lesion enhancement (t onset ), and time intervals between beginning of lesion enhancement and maximum percentage of lesion enhancement (t max ) were analyzed. All AVMs showed a high-flow hemodynamic pattern. Two significantly different (p 3.0 Tesla provides hemodynamic characterization of vascular malformations. VMs can be subclassified into two hemodynamic subgroups due to presence or absence of AVFs. • Time-resolved MRA at 3.0 Tesla provides quantitative hemodynamic characterization of vascular malformations. • Malformations significantly differ in time courses of enhancement and signal intensity increase. • AVMs show a distinctive high-flow hemodynamic pattern. • Two significantly different types of VMs emerged: VMs with and without AVFs.

  11. Comparative magnetic resonance imaging of renal space-occupying lesions with a high and a low field MRI system

    International Nuclear Information System (INIS)

    Gehl, H.B.; Lorch, H.; Amblank, O.B.M.; Engerhoff, B.; Weiss, H.D.

    1998-01-01

    Purpose: A prospective study of the diagnostic accuracy and image quality of two MRI systems in the detection of renal tumors was investigated. Materials and Methods: 34 patients with the clinical suspicion of a space-occupying renal lesion were examined by MRI with a low field (0.2 Tesla magnet) and a high field (1.5 Tesla magnet) for comparison. An 'informed' and a 'blind' observer evaluated all of the MR images. In addition, the signal-to-noise and contrast-to-noise ratios were evaluated as second quality parameters. Results: In 29 cases the results could be compared with a confirmed release diagnosis. Diagnostic accuracy was comparable with both systems (Sensitivity for both observer on LF apparatus: 83%, HF apparatus: 81%) although the signal-to-noise and contrast-to-noise ratios were significantly poorer at low field. Conclusions: The low field system in comparable to the high field MRI for detection and differentiation of renal space-occupying lesions. (orig.) [de

  12. Quantification of Liver Proton-Density Fat Fraction in an 7.1 Tesla preclinical MR Systems: Impact of the Fitting Technique

    Science.gov (United States)

    Mahlke, C; Hernando, D; Jahn, C; Cigliano, A; Ittermann, T; Mössler, A; Kromrey, ML; Domaska, G; Reeder, SB; Kühn, JP

    2016-01-01

    Purpose To investigate the feasibility of estimating the proton-density fat fraction (PDFF) using a 7.1 Tesla magnetic resonance imaging (MRI) system and to compare the accuracy of liver fat quantification using different fitting approaches. Materials and Methods Fourteen leptin-deficient ob/ob mice and eight intact controls were examined in a 7.1 Tesla animal scanner using a 3-dimensional six-echo chemical shift-encoded pulse sequence. Confounder-corrected PDFF was calculated using magnitude (magnitude data alone) and combined fitting (complex and magnitude data). Differences between fitting techniques were compared using Bland-Altman analysis. In addition, PDFFs derived with both reconstructions were correlated with histopathological fat content and triglyceride mass fraction using linear regression analysis. Results The PDFFs determined with use of both reconstructions correlated very strongly (r=0.91). However, small mean bias between reconstructions demonstrated divergent results (3.9%; CI 2.7%-5.1%). For both reconstructions, there was linear correlation with histopathology (combined fitting: r=0.61; magnitude fitting: r=0.64) and triglyceride content (combined fitting: r=0.79; magnitude fitting: r=0.70). Conclusion Liver fat quantification using the PDFF derived from MRI performed at 7.1 Tesla is feasible. PDFF has strong correlations with histopathologically determined fat and with triglyceride content. However, small differences between PDFF reconstruction techniques may impair the robustness and reliability of the biomarker at 7.1 Tesla. PMID:27197806

  13. The use of mirror image symmetry in coil winding, applications and advantages in magnetic field generation

    International Nuclear Information System (INIS)

    Grotz, T.

    1992-01-01

    In this paper, an improved method of winding inductors, transformers and motors is discovered. This invention greatly enhances the ability to generate magnetic fields with a given amount of wire. This invention may be as fundamental to the use of magnetic fields as was Nikola Tesla's use of rotating magnetic fields for the generation of alternating current

  14. Expressive/Exploratory Technical Writing (XTW) in Engineering: Shifting the Technical Writing Curriculum

    Science.gov (United States)

    Warnock, Scott; Kahn, Michael

    2007-01-01

    While the importance of "expressive writing," or informal, self-directed writing, has been well established, teachers underutilize it, particularly in technical writing courses. We introduce the term expressive/exploratory technical writing (XTW), which is the use of informal, self-directed writing to problem-solve in technical fields. We describe…

  15. Partial epilepsy: A pictorial review of 3 TESLA magnetic resonance imaging features

    Directory of Open Access Journals (Sweden)

    Lucas Giansante Abud

    2015-09-01

    Full Text Available Epilepsy is a disease with serious consequences for patients and society. In many cases seizures are sufficiently disabling to justify surgical evaluation. In this context, Magnetic Resonance Imaging (MRI is one of the most valuable tools for the preoperative localization of epileptogenic foci. Because these lesions show a large variety of presentations (including subtle imaging characteristics, their analysis requires careful and systematic interpretation of MRI data. Several studies have shown that 3 Tesla (T MRI provides a better image quality than 1.5 T MRI regarding the detection and characterization of structural lesions, indicating that high-field-strength imaging should be considered for patients with intractable epilepsy who might benefit from surgery. Likewise, advanced MRI postprocessing and quantitative analysis techniques such as thickness and volume measurements of cortical gray matter have emerged and in the near future, these techniques will routinely enable more precise evaluations of such patients. Finally, the familiarity with radiologic findings of the potential epileptogenic substrates in association with combined use of higher field strengths (3 T, 7 T, and greater and new quantitative analytical post-processing techniques will lead to improvements regarding the clinical imaging of these patients. We present a pictorial review of the major pathologies related to partial epilepsy, highlighting the key findings of 3 T MRI.

  16. Assessment of the cervical spine denticulate ligament using MRI volumetric sequence: Comparison between 1.5 Tesla and 3.0 Tesla.

    Science.gov (United States)

    Seragioli, Rafael; Simao, Marcelo Novelino; Simao, Gustavo Novelino; Herrero, Carlos Fernando P S; Nogueira-Barbosa, Marcello H

    2018-03-01

    Denticulate ligaments (DLs) are pial extensions on each side of the spinal cord, comprising about 20 to 21 pairs of fibrous structures connecting the dura mater to the spinal cord. These ligaments are significant anatomical landmarks in the surgical approach to intradural structures. To our knowledge, there is no previous study on the detection of DLs using MRI. After IRB approval, we retrospectively evaluated 116 consecutive MRI scans of the cervical spine, using the volumetric sequence 3D COSMIC, 65 and 51 studies with 1.5T and 3.0T respectively. We did not include trauma and tumor cases. Two independent radiologists assessed the detection of cervical spine DLs independently and blinded for each cervical vertebral level. We compared the frequency of detection of these ligaments in 1.5 Tesla and 3.0 Tesla MRI using Fisher exact test considering P<0.05 as significant. We evaluated interobserver agreement with Kappa coefficient. We observed high detection frequency of the cervical spine DLs using both 1.5T (70 to 91%) and 3.0T (68 to 98%). We found no statistically significant difference in the detection frequency of ligaments between the 1.5T and 3.0T MRI in all vertebral levels. Using 3.0T, radiologists identified ligaments better in higher vertebral levels than for lower cervical levels (P=0.0003). Interobserver agreement on the identification of DL was poor both for 1.5T (k=0.3744; CI 95% 0.28-0.46) and 3.0T (k=0.3044; CI 95% 0.18-0.42) MRI. Radiologists identified most of the cervical DLs using volumetric MRI acquisition. Our results suggest 1.5T and 3.0T MRI performed similarly in the detection of DLs. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  17. High field dipole magnet design concepts

    International Nuclear Information System (INIS)

    Nicol, T.H.

    1988-12-01

    High field dipole magnets will play a crucial role in the development of future accelerators whether at Fermilab or elsewhere. This paper presents conceptual designs for two such dipoles; 6.6 and 8.8 Tesla, with special focus on their suitability for upgrades to the Fermilab Tevatron. Descriptions and cross-sectional views will be presented as will preliminary estimates of heat loads and costs. 3 refs., 2 figs., 2 tabs

  18. Technical Support Essentials Advice to Succeed in Technical Support

    CERN Document Server

    Sanchez, Andrew

    2010-01-01

    Technical Support Essentials is a book about the many facets of technical support. It attempts to provide a wide array of topics to serve as points of improvement, discussion, or simply topics that you might want to learn. The topics range from good work habits to the way technical supportgroups establish their own style of work. This book applies theories, models, and concepts synthesized from existing research in other fields-such as management, economics, leadership, and psychology-and connects them to technical support. The goal is to build on the work of others and allow their success to

  19. Technical and economic feasibility study of enhanced oil recovery in six Colombian fields. Appendix C. Export trade information

    Energy Technology Data Exchange (ETDEWEB)

    1986-09-01

    The primary objectives of the study were to determine which of the reservoirs in the principal fields were amenable to enhanced oil recovery (EOR) processes, to evaluate which process was the most effective from both a technical and economic point of view, and to propose the steps required to further investigate the recommended EOR methods at the laboratory and field (pilot) level. Appendix C is divided into three sections: (A) Casabe Field; (B) La Cira Field; and (C) Tibu-Barco.

  20. Breast MRI at 7 Tesla with a bilateral coil and robust fat suppression.

    Science.gov (United States)

    Brown, Ryan; Storey, Pippa; Geppert, Christian; McGorty, KellyAnne; Klautau Leite, Ana Paula; Babb, James; Sodickson, Daniel K; Wiggins, Graham C; Moy, Linda

    2014-03-01

    To develop a bilateral coil and fat suppressed T1-weighted sequence for 7 Tesla (T) breast MRI. A dual-solenoid coil and three-dimensional (3D) T1w gradient echo sequence with B1+ insensitive fat suppression (FS) were developed. T1w FS image quality was characterized through image uniformity and fat-water contrast measurements in 11 subjects. Signal-to-noise ratio (SNR) and flip angle maps were acquired to assess the coil performance. Bilateral contrast-enhanced and unilateral high resolution (0.6 mm isotropic, 6.5 min acquisition time) imaging highlighted the 7T SNR advantage. Reliable and effective FS and high image quality was observed in all subjects at 7T, indicating that the custom coil and pulse sequence were insensitive to high-field obstacles such as variable tissue loading. 7T and 3T image uniformity was similar (P=0.24), indicating adequate 7T B1+ uniformity. High 7T SNR and fat-water contrast enabled 0.6 mm isotropic imaging and visualization of a high level of fibroglandular tissue detail. 7T T1w FS bilateral breast imaging is feasible with a custom radiofrequency (RF) coil and pulse sequence. Similar image uniformity was achieved at 7T and 3T, despite different RF field behavior and variable coil-tissue interaction due to anatomic differences that might be expected to alter magnetic field patterns. Copyright © 2013 Wiley Periodicals, Inc.

  1. System for technical innovation support

    International Nuclear Information System (INIS)

    2011-08-01

    This book lists field of support system, which includes tax, development work, basic research project, industrial technology, information and communications field, energy field, part and materials field, local industry, the small and medium business such as technical development field, and industry-university collaboration like summary of investment and financing support and guarantee, support of manpower such as brain pool and contact Korea, support of technique like development technology and strategy for patent, support on certification such as company and technical goods, purchase support.

  2. [Influence on flux density of intraoral dental magnets during 1.5 and 3.0 tesla MRI].

    Science.gov (United States)

    Blankenstein, F H; Truong, B; Thomas, A; Boeckler, A; Peroz, I

    2011-08-01

    When using dental duo-magnet systems, a mini-magnet remains in the jaw after removal of the prosthesis. In some cases, implant-borne magnets may be removed, whereas tooth-borne magnets are irreversibly fixed on a natural tooth root. The goal of this paper is to identify the impacts of the duration and orientation of exposure on these magnets in a 1.5 or 3 Tesla MRI. For this study, 30 SmCo and 60 NdFeB magnets were used. During the first experiment, they were exposed with free orientation for 64 minutes. During the second experiment, the magnets were fixed in position and exposed at 1.5 and 3 Tesla while aligned in a parallel or antiparallel direction. While the duration of exposure in MRI is irrelevant, the orientation is not. The coercive field strength of these NdFeB and SmCo alloys is not sufficient to reliably withstand demagnetization in a 1.5 or 3 T MRI when aligned in an antiparallel direction. At 1.5 T neodymium magnets were reduced to approx. 34 % and samarium magnets to approx. 92 % of their initial values. At 3 T all magnets were reversed. As a precaution, the worst-case scenario, i. e. an antiparallel orientation, should be assumed when using a duo-magnet system. If an MRI can be postponed, the general dentist should remove implant-borne magnets. If there is a vital indication, irreversible damage to the magnets is acceptable in consultation with the patient since the replacement costs are irrelevant given the underlying disease. © Georg Thieme Verlag KG Stuttgart · New York.

  3. Design parameters for a 7.2 tesla bending magnet for a 1.5 GeV compact light source

    International Nuclear Information System (INIS)

    Green, M.A.; Madura, D.

    1995-06-01

    This report describes the design for a 7.2 tesla superconducting dipole magnet for a compact synchrotron light source. The proposed magnet is a Vobly type modified picture frame dipole that has the flux returned through unsaturated iron. In this magnet, The iron in the pole pieces is highly saturated, Separately powered coils around the pole pieces are used to direct the flux lines until the flux can be returned through the unsaturated iron. The proposed dipole will develop a uniform field over a region that is 80 mm high by 130 mm wide over a range of central induction from 0.4 T to almost 8 T. Each dipole for the compact light source will have a magnetic length of about 0.38 meters

  4. Highly Sensitive Measurements of the Dark Current of Superconducting Cavities for TESLA Using a SQUID Based Cryogenic Current Comparator

    CERN Document Server

    Vodel, W; Nietzsche, S

    2004-01-01

    This contribution presents a Cryogenic Current Comparator (CCC) as an excellent tool for detecting dark currents generated, e.g. by superconducting cavities for the upcoming TESLA project (X-FEL) at DESY. To achieve the maximum possible energy the gradient of the superconducting RF cavities should be pushed close to the physical limit of 50 MV/m. The undesired field emission of electrons (so-called dark current) of the superconducting RF cavities at strong fields may limit the maximum gradient. The absolute measurement of the dark current in correlation with the gradient will give a proper value to compare and classify the cavities. The main component of the CCC is a highly sensitive LTS-DC SQUID system which is able to measure extremely low magnetic fields, e.g. caused by the dark current. For this reason the input coil of the SQUID is connected across a special designed toroidal niobium pick-up coil for the passing electron beam. A noise limited current resolution of nearly 2 pA/√(Hz) with a measu...

  5. 3.0 Tesla breast magnetic resonance imaging in patients with nipple discharge when mammography and ultrasound fail

    Energy Technology Data Exchange (ETDEWEB)

    Lubina, Nora; Schedelbeck, Ulla; Weng, Andreas Max; Hahn, Dietbert; Bley, Thorsten Alexander [University of Wuerzburg, Department of Diagnostic and Interventional Radiology, Wuerzburg (Germany); Roth, Anne [Centre of Radiology Wuerzburg, Wuerzburg (Germany); Geissinger, Eva [University of Wuerzburg, Institute of Pathology, Wuerzburg (Germany); Hoenig, Arnd [Catholic Clinical Centre Mainz, Department of Obstetrics and Gynecology, Mainz (Germany)

    2015-05-01

    To compare 3.0 Tesla breast magnetic resonance imaging (MRI) with galactography for detection of benign and malignant causes of nipple discharge in patients with negative mammography and ultrasound. We prospectively evaluated 56 breasts of 50 consecutive patients with nipple discharge who had inconspicuous mammography and ultrasound, using 3.0 Tesla breast MRI with a dedicated 16-channel breast coil, and then compared the results with galactography. Histopathological diagnoses and follow-ups were used as reference standard. Lesion size estimated on MRI was compared with the size at histopathology. Sensitivity and specificity of MRI vs. galactography for detecting pathologic findings were 95.7 % vs. 85.7 % and 69.7 % vs. 33.3 %, respectively. For the supposed concrete pathology based on MRI findings, the specificity was 67.6 % and the sensitivity 77.3 % (PPV 60.7 %, NPV 82.1 %). Eight malignant lesions were detected (14.8 %). The estimated size at breast MRI showed excellent correlation with the size at histopathology (Pearson's correlation coefficient 0.95, p < 0.0001). MRI of the breast at 3.0 Tesla is an accurate imaging test and can replace galactography in the workup of nipple discharge in patients with inconspicuous mammography and ultrasound. (orig.)

  6. Intraoperative Magnetic Resonance Imaging for Cranial and Spinal Cases Using Preexisting "C" Shaped Three Side Open 0.2 Tesla Magnetic Resonance Imaging.

    Science.gov (United States)

    Tewari, Vinod Kumar; Tripathi, Ravindra; Aggarwal, Subodh; Hussain, Mazhar; Das Gupta, Hari Kishan

    2017-01-01

    The existing Intraoperative MRI (IMRI) of developed countries is too costly to be affordable in any developing country and out of the reach of common and poor people of developing country at remote areas. We have used the pre-existing (refurbished) 3 side open "C" shaped 0.2 Tesla MRI for IMRI in a very remote area. In this technique the 0.2 Tesla MRI and the operating theatre were merged. MRI table was used as an operation table. We have operated 36 cases via IMRI from November 2005 to till date. First case operated was on 13 th nov 2005. Low (0.2) Tesla open setup costs very low (around Rs 40 lakhs) so highly affordable to management and thus to patients, used for diagnostic and therapeutic purposes both, the equipments like Nitrous, oxygen and suction is outside the MRI room so no noise inside operative room, positioning the patient didn't take much time due to manual adjustments, no special training to nurses and technicians required because of low (0.2) Tesla power of magnet and same instruments and techniques, sequencing took only 1.31 mints per sequence and re registration is not required since we always note down the two orthogonal axis in x and y axis in preoperative imaging and we were able to operate on posterior fossa tumors as well because of no head fixation except with leucoplast strap. Moreover the images we got intraoperative are highly acceptable. Three side open 0.2 Tesla MRI system, if used for intraoperative guidance, is highly affordable and overcomes the limitations of western setup of IMRI. Postoperative MRI images were highly acceptable and also highly affordable too.

  7. BOLD cardiovascular magnetic resonance at 3.0 tesla in myocardial ischemia.

    OpenAIRE

    Manka, R; Paetsch, I; Schnackenburg, B; Gebker, R; Fleck, E; Jahnke, C

    2010-01-01

    Abstract Background The purpose of this study was to determine the ability of Blood Oxygen Level Dependent (BOLD) cardiovascular magnetic resonance (CMR) to detect stress-inducible myocardial ischemic reactions in the presence of angiographically significant coronary artery disease (CAD). Methods Forty-six patients (34 men; age 65 ± 9 years,) with suspected or known coronary artery disease underwent CMR at 3Tesla prior to clinically indicated invasive coronary angiography. BOLD CMR was perfor...

  8. Conceptual studies of toroidal field magnets for the tokamak (fusion) experimental power reactor. Final report

    International Nuclear Information System (INIS)

    1976-01-01

    This report presents the results of ''Conceptual Studies of Toroidal Field Magnets for the Tokamak Experimental Power Reactor'' performed for the Energy Research and Development Administration, Oak Ridge Operations. Two conceptual coil designs are developed. One design approach to produce a specified 8 Tesla maximum field uses a novel NbTi superconductor design cooled by pool-boiling liquid helium. For a highest practicable field design, a unique NbSn 3 conductor is used with forced-flow, single-phase liquid helium cooling to achieve a 12 Tesla peak field. Fabrication requirements are also developed for these approximately 7 meter horizontal bore by 11 meter vertical bore coils. Cryostat design approaches are analyzed and a hybrid cryostat approach selected. Structural analyses are performed for approaches to support in-plane and out-of-plane loads and a structural approach selected. In addition to the conceptual design studies, cost estimates and schedules are prepared for each of the design approaches, major uncertainties and recommendations for research and development identified, and test coil size for demonstration recommended

  9. Multidirectional pseudodynamic studies of the bilateral temporomandibular joint diseases with 0.2-Tesla MR imaging unit

    International Nuclear Information System (INIS)

    Sasaki, Makoto; Ehara, Shigeru; Nakasato, Tatsuhiko; Tamakawa, Yoshiharu; Sugisawa, Miyoshi; Iwahana, Hideaki; Kuboya, Yasuo.

    1996-01-01

    Sagittal and coronal images of the bilateral temporomandibular joint (TMJ) simultaneously have been obtained to evaluate displacement of the meniscus in nine patients with TMJ clicking using a 0.2-Tesla permanent magnetic unit. The obtained images were displayed in closed loop cine fashion and recorded on videotapes. Anterior displacement of meniscus was seen on sagittal images in 5 of 9 paients. In the other four patients, no anterior displacement was observed, but in three of them, medial and lateral displacement on coronal images were shown in the closed position. Even using the 0.2-Tesla unit, simultaneous pseudodynamic display of the bilateral TMJ in sagittal and coronal planes was useful for evaluating internal derangement of the TMJ. This technique not only saves time but provides accurate evaluation of meniscal position and motion. (H.O.)

  10. Image-guided spinal injection procedures in open high-field MRI with vertical field orientation: feasibility and technical features

    Energy Technology Data Exchange (ETDEWEB)

    Streitparth, F.; Walter, T.; Wonneberger, U.; Wagner, M.; Hermann, K.G.; Hamm, B.; Teichgraeber, U. [Charite, Humboldt-Universitaet zu Berlin, Department of Radiology, Berlin (Germany); Chopra, S. [Charite-Universitaetsmedizin Berlin, Campus Virchow Klinikum, Department of General, Visceral, and Transplantation Surgery, Berlin (Germany); Wichlas, F. [Charite-Universitaetsmedizin Berlin, Campus Virchow Klinikum, Center for Musculoskeletal Surgery, Berlin (Germany)

    2010-02-15

    We prospectively evaluated the feasibility and technical features of MR-guided lumbosacral injection procedures in open high-field MRI at 1.0 T. In a CuSO{sub 4}.5H{sub 2}O phantom and five human cadaveric spines, fluoroscopy sequences (proton-density-weighted turbo spin-echo (PDw TSE), T1w TSE, T2w TSE; balanced steady-state free precession (bSSFP), T1w gradient echo (GE), T2w GE) were evaluated using two MRI-compatible 20-G Chiba-type needles. Artefacts were analysed by varying needle orientation to B{sub 0}, frequency-encoding direction and slice orientation. Image quality was described using the contrast-to-noise ratio (CNR). Subsequently, a total of 183 MR-guided nerve root (107), facet (53) and sacroiliac joint (23) injections were performed in 53 patients. In vitro, PDw TSE sequence yielded the best needle-tissue contrasts (CNR = 45, 18, 15, 9, and 8 for needle vs. fat, muscle, root, bone and sclerosis, respectively) and optimal artefact sizes (width and tip shift less than 5 mm). In vivo, PDw TSE sequence was sufficient in all cases. The acquisition time of 2 s facilitated near-real-time MRI guidance. Drug delivery was technically successful in 100% (107/107), 87% (46/53) and 87% (20/23) of nerve root, facet and sacroiliac joint injections, respectively. No major complications occurred. The mean procedure time was 29 min (range 19-67 min). MR-guided spinal injections in open high-field MRI are feasible and accurate using fast TSE sequence designs. (orig.)

  11. Encouraging a "Romantic Understanding" of Science: The Effect of the Nikola Tesla Story

    Science.gov (United States)

    Hadzigeorgiou, Yannis; Klassen, Stephen; Klassen, Cathrine Froese

    2012-01-01

    The purpose of this paper is to discuss and apply the notion of romantic understanding by outlining its features and its potential role in science education, to identify its features in the story of Nikola Tesla, and to describe an empirical study conducted to determine the effect of telling such a story to Grade 9 students. Elaborated features of…

  12. Technical Network

    CERN Multimedia

    2007-01-01

    In order to optimize the management of the Technical Network (TN), to ease the understanding and purpose of devices connected to the TN, and to improve security incident handling, the Technical Network Administrators and the CNIC WG have asked IT/CS to verify the "description" and "tag" fields of devices connected to the TN. Therefore, persons responsible for systems connected to the TN will receive email notifications from IT/CS asking them to add the corresponding information in the network database. Thank you very much for your cooperation. The Technical Network Administrators & the CNIC WG

  13. Toroidal magnetic field system for a 2-MA reversed-field pinch experiment

    International Nuclear Information System (INIS)

    Melton, J.G.; Linton, T.W.

    1983-01-01

    The engineering design of the toroidal magnetic field (TF) system for a 2-MA Reversed-Field Pinch experiment (ZT-H) is described. ZT-H is designed with major radius 2.15 meters, minor radius 0.40 meters, and a peak toroidal magnetic field of 0.85 Tesla. The requirement for highly uniform fields, with spatial ripple <0.2% leads to a design with 72 equally spaced circular TF coils, located at minor radius 0.6 meters, carrying a maximum current of 9.0 MA. The coils are driven by a 12-MJ capacitor bank which is allowed to ring in order to aid the reversal of magnetic field. A stress analysis is presented, based upon calculated hoop tension, centering force, and overturning moment, treating these as a combination of static loads and considering that the periodic nature of the loading causes little amplification. The load transfer of forces and moments is considered as a stress distribution resisted by the coils, support structures, wedges, and the structural shell

  14. Large-scale building integrated photovoltaics field trial. First technical report - installation phase

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2004-07-01

    This report summarises the results of the first eighteen months of the Large-Scale Building Integrated Photovoltaic Field Trial focussing on technical aspects. The project aims included increasing awareness and application of the technology, raising the UK capabilities in application of the technology, and assessing the potential for building integrated photovoltaics (BIPV). Details are given of technology choices; project organisation, cost, and status; and the evaluation criteria. Installations of BIPV described include University buildings, commercial centres, and a sports stadium, wildlife park, church hall, and district council building. Lessons learnt are discussed, and a further report covering monitoring aspects is planned.

  15. ENERGY GAIN BY MEANS OF RESONANCE IN THE TESLA COIL

    Directory of Open Access Journals (Sweden)

    Yu. Batygin

    2016-12-01

    Full Text Available An analytical review of publications on the problem, first formulated by Nikola Tesla, generating «free» energy from the air in the surrounding space has been presented. The hypothesis of the resonance phenomenon as a «key» to the air energy has been advanced. The main unsolved problem is the extrac-tion of «free» energy (proposed to call it «resonance» and its supply to the electrical load have been noted. It is expected that the quality factor of the secondary circuit must be large enough.

  16. System aspects of managing international scientific and technical as well as manufacturing economic cooperation in the nuclear power field

    International Nuclear Information System (INIS)

    Drahny, M.

    1988-01-01

    International scientific and technical cooperation in nuclear power is discussed from the angle of systems control aspects. Integration benefit and the development stages of the integration process are mainly treated. The researcher-user relations are analysed in detail in scientific and technical cooperation and its links to economic cooperation. In nuclear power within COMECON countries, the most important field of cooperation currently is the complex program of scientific and technical progress of the COMECON member countries till the year 2000, especially its third priority trend called Accelerated Development of Nuclear Power. The following new quality should be thereby provided for the participating states: the achievement of the world peak standards of technical and economic parameters; the reflection of scientific and technical and economic cooperation in a complete innovatory cycle Science-Technology-Production-Application; the achievement of direct labor relations of the participating research, development, production and end user organizations. (Z.M.). 1 fig., 16 refs

  17. Field Implementation Plan for the In-Situ Bioremediation Treatability Study at the Technical Area-V Groundwater Area of Concern

    Energy Technology Data Exchange (ETDEWEB)

    Li, Jun [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2016-10-31

    This Field Implementation Plan (FIP) was prepared by Sandia National Laboratories, New Mexico (SNL/NM) and provides instruction on conducting a series of in-situ bioremediation (ISB) tests as described in the Revised Treatability Study Work Plan for In-Situ Bioremediation at the Technical Area-V Groundwater Area of Concern, referred to as the Revised Work Plan in this FIP. The Treatability Study is designed to gravity inject an electron-donor substrate and bioaugmentation bacteria into groundwater via three injection wells to perform bioremediation of the constituents of concern (COCs), nitrate and trichloroethene (TCE), in the regions with the highest concentrations at the Technical Area-V Groundwater (TAVG) Area of Concern (AOC). The Treatability Study will evaluate the effectiveness of bioremediation solution delivery and COC treatment over time. This FIP is designed for SNL/NM work planning and management. It is not intended to be submitted for regulator’s approval. The technical details presented in this FIP are subject to change based on field conditions, availability of equipment and materials, feasibility, and inputs from Sandia personnel and Aboveground Injection System contractor.

  18. Field Implementation Plan for the In-Situ Bioremediation Treatability Study at the Technical Area-V Groundwater Area of Concern

    International Nuclear Information System (INIS)

    Li, Jun

    2016-01-01

    This Field Implementation Plan (FIP) was prepared by Sandia National Laboratories, New Mexico (SNL/NM) and provides instruction on conducting a series of in-situ bioremediation (ISB) tests as described in the Revised Treatability Study Work Plan for In-Situ Bioremediation at the Technical Area-V Groundwater Area of Concern, referred to as the Revised Work Plan in this FIP. The Treatability Study is designed to gravity inject an electron-donor substrate and bioaugmentation bacteria into groundwater via three injection wells to perform bioremediation of the constituents of concern (COCs), nitrate and trichloroethene (TCE), in the regions with the highest concentrations at the Technical Area-V Groundwater (TAVG) Area of Concern (AOC). The Treatability Study will evaluate the effectiveness of bioremediation solution delivery and COC treatment over time. This FIP is designed for SNL/NM work planning and management. It is not intended to be submitted for regulator's approval. The technical details presented in this FIP are subject to change based on field conditions, availability of equipment and materials, feasibility, and inputs from Sandia personnel and Aboveground Injection System contractor.

  19. Occupational exposure to ambient electromagnetic fields of technical operational personnel working for a mobile telephone operator

    International Nuclear Information System (INIS)

    Chauvin, S.; Gibergues, M. L.; Wuethrich, G.; Picard, D.; Desreumaux, J. P.; Bouillet, J. C.

    2009-01-01

    In order to investigate the exposure of operational personnel to radiofrequency electromagnetic fields when working for a mobile telephone operator, exposimeters were used to make individual records on 23 Technical Operations personnel (mobile telephone maintenance staff) and also on 22 Other Workers. The exposure densities, to which each of the 45 subjects was subjected, were quantified using 229 exposure indicators. Cluster analysis techniques were applied to the data, in an attempt to show that they would re-emerge as belonging to one of the two groups, i.e. the Technical Operational Personnel group or the Other Workers group. This exploratory investigation has shown that the cluster analysis does not reveal a sufficiently reliable emergence of the two groups, even though certain exposure indicators were significantly different for the two groups. In addition, the use of a Learning Group method does not lead to the discovery of a predictive law that could identify the Technical Operational Personnel as a sub-group within the overall group. (authors)

  20. Risk based regulation: a convenient concept for legislation and regulation in the field of technical risks?

    International Nuclear Information System (INIS)

    Seiler, J.H.

    1998-01-01

    Legislation and regulation concerning risk activities are traditionally based on deterministic safety measures. This may lead to inefficient results: sometimes the law requires safety measures which are - from an economic viewpoint - not justified because of their poor cost-effectiveness; sometimes it does not require safety measures although they would be very efficient. The risk based regulation approach wants to make the law more efficient and to get more safety at less costs. Legislation and regulation should be based on terms of risk rather than on deterministic rules. Risk should be expressed in quantitative terms and risk regulation should be based on the cost-effectiveness of safety measures. Thus a most efficient (in the sense of the economic analysis of the law) strategy for safety and environmental law could be established. The approach is economically reasonable and theoretically convincing. Its practical implementation however raises a lot of technical and legal questions. The project 'Risk Based Regulation' (1996-1999), sponsored by the Swiss National Fund for Scientific Research, intends to evaluate the practical feasibility of the approach from a technical and a legal view. It contains a general part which describes the risk based regulation approach and its legal and technical questions, case studies which try to practically implement the risk based regulation approach; the case studies are: storage and management of explosives in the army, storage and management of explosives for non-military purposes, safety at work, accident prevention in the non-professional field (mainly road accidents), fire protection, transportation of dangerous goods, waste disposal: traditional waste, waste disposal: radioactive waste, nuclear energy (reactor safety), a synthesis with recommendations for the future legislation and regulation in the field of technical risks. The paper presents the project and its preliminary results. (author)

  1. Magnetic resonance imaging investigation of the bone conduction implant – a pilot study at 1.5 Tesla

    Science.gov (United States)

    Jansson, Karl-Johan Fredén; Håkansson, Bo; Reinfeldt, Sabine; Rigato, Cristina; Eeg-Olofsson, Måns

    2015-01-01

    Purpose The objective of this pilot study was to investigate if an active bone conduction implant (BCI) used in an ongoing clinical study withstands magnetic resonance imaging (MRI) of 1.5 Tesla. In particular, the MRI effects on maximum power output (MPO), total harmonic distortion (THD), and demagnetization were investigated. Implant activation and image artifacts were also evaluated. Methods and materials One implant was placed on the head of a test person at the position corresponding to the normal position of an implanted BCI and applied with a static pressure using a bandage and scanned in a 1.5 Tesla MRI camera. Scanning was performed both with and without the implant, in three orthogonal planes, and for one spin-echo and one gradient-echo pulse sequence. Implant functionality was verified in-between the scans using an audio processor programmed to generate a sequence of tones when attached to the implant. Objective verification was also carried out by measuring MPO and THD on a skull simulator as well as retention force, before and after MRI. Results It was found that the exposure of 1.5 Tesla MRI only had a minor effect on the MPO, ie, it decreased over all frequencies with an average of 1.1±2.1 dB. The THD remained unchanged above 300 Hz and was increased only at lower frequencies. The retention magnet was demagnetized by 5%. The maximum image artifacts reached a distance of 9 and 10 cm from the implant in the coronal plane for the spin-echo and the gradient-echo sequence, respectively. The test person reported no MRI induced sound from the implant. Conclusion This pilot study indicates that the present BCI may withstand 1.5 Tesla MRI with only minor effects on its performance. No MRI induced sound was reported, but the head image was highly distorted near the implant. PMID:26604836

  2. Technical Network

    CERN Multimedia

    2007-01-01

    In order to optimise the management of the Technical Network (TN), to facilitate understanding of the purpose of devices connected to the TN and to improve security incident handling, the Technical Network Administrators and the CNIC WG have asked IT/CS to verify the "description" and "tag" fields of devices connected to the TN. Therefore, persons responsible for systems connected to the TN will receive e-mails from IT/CS asking them to add the corresponding information in the network database at "network-cern-ch". Thank you very much for your cooperation. The Technical Network Administrators & the CNIC WG

  3. Chemical exchange saturation transfer MR imaging of Parkinson's disease at 3 Tesla

    International Nuclear Information System (INIS)

    Li, Chunmei; Peng, Shuai; Wang, Rui; Chen, Min; Chen, Haibo; Su, Wen; Zhao, Xuna; Zhou, Jinyuan

    2014-01-01

    To demonstrate the feasibility of using chemical exchange saturation transfer (CEST) imaging to detect Parkinson's disease (PD) in patients at 3 Tesla. Twenty-seven PD patients (17 men and 10 women; age range, 54-77 years) and 22 age-matched normal controls (13 men and 9 women; age range, 55-73 years) were examined on a 3-Tesla MRI system. Magnetization transfer spectra with 31 different frequency offsets (-6 to 6 ppm) were acquired at two transverse slices of the head, including the basal ganglia and midbrain. One-way analysis of variance tests was used to compare the differences in CEST imaging signals between PD patients and normal controls. Total CEST signal between the offsets of 0 and 4 ppm in the substantia nigra was significantly lower in PD patients than in normal controls (P = 0.006), which could be associated with the loss of dopaminergic neurons. Protein-based CEST imaging signals at the offset of 3.5 ppm in the globus pallidus, putamen and caudate were significantly increased in PD patients, compared to normal controls (P < 0.001, P = 0.003, P < 0.001, respectively). CEST imaging signals could potentially serve as imaging biomarkers to aid in the non-invasive molecular diagnosis of PD. (orig.)

  4. Magnetic resonance imaging in patients with cardiac pacemakers: In vitro-and vivo-evaluation at 0.5 Tesla

    International Nuclear Information System (INIS)

    Sommer, T.; Block, W.; Schild, H.; Schimpf, R.; Smekal, A. v.; Wolke, S.; Gieseke, J.; Schneider, C.; Funke, H.D.

    1998-01-01

    Purpose: MRI is currently regarded as absolutely contraindicated in patients with implanted cardiac pacemakers. In this prospective study safety and feasibility of MRI in patients with new generation pacemakers (PM) was evaluated in vitro and in vivo. Results: In the static magnetic field all PM switched to the asynchronous mode due to activation of the Reed switch, resulting in continuous pacing at a fixed rate. In three PM models in vitro, however, after activation of the Reed switch, there was a software-induced switch back to the demand mode. In these PM inhibition and triggering were observed after starting the MRI scan due to influence of the pulsed magnetic fields. PM program changes, damage of PM components, dislocation/torque of the PM and rapid pacing of the PM were observed neither in vitro nor in vivo. Atrial and ventricular stimulation thresholds remained unchanged. Conclusion: MRI at 0.5 Tesla should not be regarded as absolutely contraindicated in patients with implanted new generation PM. However, knowledge of the behaviour of the specific PM model in static and pulsed magnetic fields is required, if necessary also changes of the PM program prior of the MRI exam, continuous ECG monitoring and cardiological stand-by. (orig.) [de

  5. General Atomic's superconducting toroidal field coil concept

    International Nuclear Information System (INIS)

    Alcorn, J.; Purcell, J.

    1978-01-01

    General Atomic's concept for a superconducting toroidal field coil is presented. The concept is generic for large tokamak devices, while a specific design is indicated for a 3.8 meter (major radius) ignition/burn machine. The concept utilizes bath cooled NbTi conductor to generate a peak field of 10 tesla at 4.2 K. The design is simple and straightforward, requires a minimum of developmental effort, and draws extensively upon the perspective of past experience in the design and construction of large superconducting magnets for high energy physics. Thus, the primary emphasis is upon economy, reliability, and expeditious construction scheduling. (author)

  6. Detection of glucose in the human brain with 1 H MRS at 7 Tesla.

    Science.gov (United States)

    Kaiser, Lana G; Hirokazu, Kawaguchi; Fukunaga, Masaki; B Matson, Gerald

    2016-12-01

    A new method is proposed for noninvasive detection of glucose in vivo using proton MR spectroscopy at 7 Tesla. The proposed method utilizes J-difference editing to uncover the resonance of beta-glucose (β-glc) at 3.23 ppm, which is strongly overlapped with choline. Calculations using the density matrix formalism are used to maximize the signal-to-noise ratio of the β-glc resonance at 3.23 ppm. The calculations are verified using phantom and in vivo data collected at 7 Tesla. The proposed method allows observation of the glucose signal at 3.23 ppm in the human brain spectrum. Additional co-edited resonances of N-acetylaspartylglutamatate and glutathione are also detected in the same experiment. The proposed method does not require carbon ( 13 C)- labeled glucose injections and 13 C hardware; as such, it has a potential to provide valuable information on intrinsic glucose concentration in the human brain in vivo. Magn Reson Med 76:1653-1660, 2016. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  7. Magnetic Fields on the National Ignition Facility (MagNIF)

    International Nuclear Information System (INIS)

    Mason, D.; Folta, J.

    2016-01-01

    A magnetized target capability on the National Ignition Facility (NIF) at Lawrence Livermore National Laboratory (LLNL) has been investigated. Stakeholders' needs and project feasibility analysis were considered in order to down-select from a wide variety of different potential magnetic field magnitudes and volumes. From the large range of different target platforms, laser configurations, and diagnostics configurations of interest to the stakeholders, the gas-pipe platform has been selected for the first round of magnetized target experiments. Gas pipe targets are routinely shot on the NIF and provide unique value for external collaborators. High-level project goals have been established including an experimentally relevant 20Tesla magnetic field magnitude. The field will be achieved using pulsed power-driven coils. A system architecture has been proposed. The pulsed power drive system will be located in the NIF target bay. This decision provides improved maintainability and mitigates equipment safety risks associated with explosive failure of the drive capacitor. High-level and first-level subsystem requirements have been established. Requirements have been included for two distinct coil designs - full solenoid and quasi-Helmholtz. A Failure Modes and Effects Analysis (FMEA) has been performed and documented. Additional requirements have been derived from the mitigations included in the FMEA document. A project plan is proposed. The plan includes a first phase of electromagnetic simulations to assess whether the design will meet performance requirements, then a second phase of risk mitigation projects to address the areas of highest technical risk. The duration from project kickoff to the first magnetized target shot is approximately 29 months.

  8. Magnetic Fields on the National Ignition Facility (MagNIF)

    Energy Technology Data Exchange (ETDEWEB)

    Mason, D. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Folta, J. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2016-08-12

    A magnetized target capability on the National Ignition Facility (NIF) at Lawrence Livermore National Laboratory (LLNL) has been investigated. Stakeholders’ needs and project feasibility analysis were considered in order to down-select from a wide variety of different potential magnetic field magnitudes and volumes. From the large range of different target platforms, laser configurations, and diagnostics configurations of interest to the stakeholders, the gas-pipe platform has been selected for the first round of magnetized target experiments. Gas pipe targets are routinely shot on the NIF and provide unique value for external collaborators. High-level project goals have been established including an experimentally relevant 20Tesla magnetic field magnitude. The field will be achieved using pulsed power-driven coils. A system architecture has been proposed. The pulsed power drive system will be located in the NIF target bay. This decision provides improved maintainability and mitigates equipment safety risks associated with explosive failure of the drive capacitor. High-level and first-level subsystem requirements have been established. Requirements have been included for two distinct coil designs – full solenoid and quasi-Helmholtz. A Failure Modes and Effects Analysis (FMEA) has been performed and documented. Additional requirements have been derived from the mitigations included in the FMEA document. A project plan is proposed. The plan includes a first phase of electromagnetic simulations to assess whether the design will meet performance requirements, then a second phase of risk mitigation projects to address the areas of highest technical risk. The duration from project kickoff to the first magnetized target shot is approximately 29 months.

  9. Electronic Communities: a Forum for Supporting Women Professionals and Students in Technical and Scientific Fields

    Science.gov (United States)

    Single, Peg Boyle; Muller, Carol B.; Cunningham, Christine M.; Single, Richard M.

    In this article, we report on electronic discussion lists (e-lists) sponsored by MentorNet, the National Electronic Industrial Mentoring Network for Women in Engineering and Science. Using the Internet, the MentorNet program connects students in engineering and science with mentors working in industry. These e-lists are a feature of MentorNet's larger electronic mentoring program and were sponsored to foster the establishment of community among women engineering and science students and men and women professionals in those fields. This research supports the hypothesis that electronic communications can be used to develop community among engineering and science students and professionals and identifies factors influencing the emergence of electronic communities (e-communities). The e-lists that emerged into self-sustaining e-communities were focused on topic-based themes, such as balancing personal and work life, issues pertaining to women in engineering and science, and job searching. These e-communities were perceived to be safe places, embraced a diversity of opinions and experiences, and sanctioned personal and meaningful postings on the part of the participants. The e-communities maintained three to four simultaneous threaded discussions and were sustained by professionals who served as facilitators by seeding the e-lists with discussion topics. The e-lists were sponsored to provide women students participating in MentorNet with access to groups of technical and scientific professionals. In addition to providing benefits to the students, the e-lists also provided the professionals with opportunities to engage in peer mentoring with other, mostly female, technical and scientific professionals. We discuss the implications of our findings for developing e-communities and for serving the needs of women in technical and scientific fields.

  10. Requirements, design and specifications of a multipurpose 7 Tesla NMR-system

    International Nuclear Information System (INIS)

    Mehlkopf, A.F.

    1978-01-01

    The requirements as well as the design and the specifications of a multi-purpose high resolution nuclear magnetic resonance spectrometer with superconducting magnet are described. The spectrometer operates at a magnetic fluxdensity of 7 Tesla and has 5 transmitter channels with 4 different frequencies, which can have values between 20 and 300 MHz. With this spectrometer almost all the current high resolution magnetic resonance techniques can be performed under computer control. It can also operate in the non-computer controlled slow passage mode. (Auth.)

  11. The future is yours--Get ready! Career options in scientific and technical fields. Revision

    Energy Technology Data Exchange (ETDEWEB)

    1992-10-01

    This 50 page brochure was developed by Brookhaven National Laboratory to encourage high school students to begin considering careers in the scientific and technical fields. The topics of the brochure include career selection, career options, a review of training required for each occupation, a collection of profiles of BNL employees describing how they chose and prepared for their careers, a description of BNL educational programs for high school students, and profiles of some of the students participating in these programs.

  12. Fiscal 1997 report on the results of the technical development of super metal under consignment from NEDO. Technology to create ferrous mesoscopic structure control materials; Super metal no gijutsu kaihatsu (tetsukei mesoscopic soshiki seigyo zairyo sosei gijutsu) seika hokokusho (1997 nendo). Shin Energy Sangyo Gijutsu Sogo Kaihatsu Kiko (NEDO) itaku kenkyu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-03-01

    The fiscal 1997 results were reported of the project on the technical development of super metal which draws out limit performance of ferrous metal and improves the recyclability. In the study of large-strain deformation, a study was carried out with the use of large-strain deformation of more than 50% per 1 pass (strain rate: 0.7 or more) and multi-phase structure. By the crystal microstructuring technology, a level was reached where approximately 1{mu}m crystal size can be obtained. In the study of high magnetic field utilization, the course of study of the structure control and microstructuring was chosen in the preliminary experiment using the existing 8 tesla magnet, and the design and fabrication of a new 12 tesla large-diameter magnet were conducted. In the study of material structure prediction, modeling of microstructuring by recrystallization and establishment of a material predicting method of micro/multi-phase/mixed-grain structures were made the subjects. In the analysis of the mesoscopic structure, the mesoscopic analysis was made of the 0.3C-9Ni steel microstructured by the large-strain deformation thermal processing, and it was shown that the reflective electronic image measured by varying accelerating voltage gives new structural information. 111 refs., 135 figs., 35 tabs.

  13. Technical mechanics in constructional reactor safety

    International Nuclear Information System (INIS)

    Matthees, W.

    1979-01-01

    Reactor safety is based on close cooperation between a number of technical and scientific disciplines; most problems of reactor technology can be solved with the aid of technical mechanics. At the 5th International Conference on Structural Mechanics in Reactor Technology (5th SMIRT), one of the biggest conferences in the field of applied technical mechanics, about 800 papers were read giving the latest state of knowledge in the field of constructional reactor safety. The main subject of the conference was the analysis of material behaviour under high loads; the information and methods of these analysis go far beyond what is required in the conventional field. (orig./UA) [de

  14. Comparison of pelvic phased-array versus endorectal coil magnetic resonance imaging at 3 Tesla for local staging of prostate cancer.

    Science.gov (United States)

    Kim, Bum Soo; Kim, Tae-Hwan; Kwon, Tae Gyun; Yoo, Eun Sang

    2012-05-01

    Several studies have demonstrated the superiority of endorectal coil magnetic resonance imaging (MRI) over pelvic phased-array coil MRI at 1.5 Tesla for local staging of prostate cancer. However, few have studied which evaluation is more accurate at 3 Tesla MRI. In this study, we compared the accuracy of local staging of prostate cancer using pelvic phased-array coil or endorectal coil MRI at 3 Tesla. Between January 2005 and May 2010, 151 patients underwent radical prostatectomy. All patients were evaluated with either pelvic phased-array coil or endorectal coil prostate MRI prior to surgery (63 endorectal coils and 88 pelvic phased-array coils). Tumor stage based on MRI was compared with pathologic stage. We calculated the specificity, sensitivity and accuracy of each group in the evaluation of extracapsular extension and seminal vesicle invasion. Both endorectal coil and pelvic phased-array coil MRI achieved high specificity, low sensitivity and moderate accuracy for the detection of extracapsular extension and seminal vesicle invasion. There were statistically no differences in specificity, sensitivity and accuracy between the two groups. Overall staging accuracy, sensitivity and specificity were not significantly different between endorectal coil and pelvic phased-array coil MRI.

  15. 21 Tesla Fourier Transform Ion Cyclotron Resonance Mass Spectrometer Greatly Expands Mass Spectrometry Toolbox

    Energy Technology Data Exchange (ETDEWEB)

    Shaw, Jared B.; Lin, Tzu-Yung; Leach, Franklin E.; Tolmachev, Aleksey V.; Tolić, Nikola; Robinson, Errol W.; Koppenaal, David W.; Paša-Tolić, Ljiljana

    2016-10-12

    We provide the initial performance evaluation of a 21 Tesla Fourier transform ion cyclotron resonance mass spectrometer operating at the Environmental Molecular Sciences Laboratory at Pacific Northwest National Laboratory. The spectrometer constructed for the 21T system employs a commercial dual linear ion trap mass spectrometer coupled to a FTICR spectrometer designed and built in-house. Performance gains from moving to higher magnetic field strength are exemplified by the measurement of peptide isotopic fine structure, complex natural organic matter mixtures, and large proteins. Accurate determination of isotopic fine structure was demonstrated for doubly charged substance P with minimal spectral averaging, and 8,158 molecular formulas assigned to Suwannee River Fulvic Acid standard with RMS error of 10 ppb. We also demonstrated superior performance for intact proteins; namely, broadband isotopic resolution of the entire charge state distribution of apotransferrin (78 kDa) and facile isotopic resolution of monoclonal antibody under a variety of acquisition parameters (e.g. 6 s time-domains with absorption mode processing yielded resolution of approximately 1M at m/z =2,700).

  16. Technical Training: Technical Training Seminar

    CERN Multimedia

    2004-01-01

    TECHNICAL TRAINING Monique Duval tel. 74924 technical.training@cern.ch Monday 9 February 2004 From 10:00 to 12:00 - IT Auditorium - bldg. 31, 3rd floor ANSOFT High-Frequency Seminar David Prestaux, Application Engineer, ANSOFT F-78535 BUC, France This Technical Training seminar will present two Ansoft application products: Ansoft HFSS and Ansoft Designer. Ansoft HFSS makes use of the Finite Element Method (FEM) to calculate field solutions from first principles. It can accurately predict all high-frequency behaviours such as dispersion, mode conversion, and losses due to materials and radiation. Ansoft Designer is a suite of design tools to fully integrate high-frequency, physics-based electromagnetic simulations into a seamless system-level simulation environment. Ansoft Designer uses a simple interface to give complete control over every design task, by a method allowing multiple solvers, Solver on Demand. • Introduction • Overview of the Ansoft Total solution • Ansoft HFSS 9...

  17. Who recognises technical standards in TTIP?

    NARCIS (Netherlands)

    Purnhagen, K.

    2018-01-01

    Current political discussions on the relationship of technical standards to the Transatlantic, Trade and Investment Partnership (TTIP) concern the question whether TTIP can provide a transatlantic level playing field for technical standards, and whether this will negatively affect technical

  18. Accuracy of accelerated cine MR imaging at 3 Tesla in longitudinal follow-up of cardiac function

    International Nuclear Information System (INIS)

    Sandner, Torleif A.; Huber, Armin M.; Theisen, Daniel; Reiser, Maximilian F.; Wintersperger, Bernd J.; Houck, Philip; Runge, Val M.; Sincleair, Spencer

    2008-01-01

    The ability of fast, parallel-imaging-based cine magnetic resonance (MR) to monitor global cardiac function in longitudinal exams at 3 Tesla was evaluated. Seventeen patients with chronic cardiac disease underwent serial cine MR imaging exams (n=3) at 3 Tesla. Data were acquired in short-axis orientation using cine steady-state free precession (SSFP) with a spatial resolution of 2.5 x 1.9 mm 2 at 45 ms temporal resolution. Multislice imaging (three slices/breath-hold) was performed using TSENSE acceleration (R=3) and standard single-slice cine (non-TSENSE) was performed at identical locations in consecutive breath-holds. End-diastolic volume (EDV), end-systolic volume (ESV), ejection fraction (EF) and myocardial mass (MM) of both cine approaches were compared for individual time-points as well as for longitudinal comparison. TSENSE-cine did not show significant differences for EDV (2.6 ml; P=.79), ESV (2.2 ml; P=0.81), EF (-0.3%; P=0.95) and MM (2.4 g; P=0.72) in comparison with non-TSENSE. Longitudinal ANOVA analysis did not reveal significant differences for any parameter, neither for non-TSENSE data (all P>0.7) nor for TSENSE data (all P>0.9). Multifactorial ANOVA showed non-significant differences (all P>0.7) at comparable data variances. Data acquisition was significantly shortened using TSENSE. Threefold accelerated multislice cine at 3 Tesla allows accurate assessment of volumetric LV data and accurate longitudinal monitoring of global LV function at a substantially shorter overall examination time. (orig.)

  19. Seven tesla MRI improves detection of focal cortical dysplasia in patients with refractory focal epilepsy

    NARCIS (Netherlands)

    Veersema, Tim J; Ferrier, Cyrille H; van Eijsden, Pieter; Gosselaar, Peter H; Aronica, Eleonora; Visser, Fredy; Zwanenburg, Jaco M; de Kort, Gerard A P; Hendrikse, Jeroen; Luijten, Peter R; Braun, Kees P J

    Objective: The aim of this study is to determine whether the use of 7 tesla (T) MRI in clinical practice leads to higher detection rates of focal cortical dysplasias in possible candidates for epilepsy surgery. Methods: In our center patients are referred for 7 T MRI if lesional focal epilepsy is

  20. Magnetic field decay in model SSC dipoles

    International Nuclear Information System (INIS)

    Gilbert, W.S.; Althaus, R.F.; Barale, P.J.; Benjegerdes, R.W.; Green, M.A.; Green, M.I.; Scanlan, R.M.

    1988-08-01

    We have observed that some of our model SSC dipoles have long time constant decays of the magnetic field harmonics with amplitudes large enough to result in significant beam loss, if they are not corrected. The magnets were run at constant current at the SSC injection field level of 0.3 tesla for one to three hours and changes in the magnetic field were observed. One explanation for the observed field decay is time dependent superconductor magnetization. Another explanation involves flux creep or flux flow. Data are presented on how the decay changes with previous flux history. Similar magnets with different Nb-Ti filament spacings and matrix materials have different long time field decay. A theoretical model using proximity coupling and flux creep for the observed field decay is discussed. 10 refs., 5 figs., 2 tabs

  1. 3.0 Tesla breast magnetic resonance imaging in patients with nipple discharge when mammography and ultrasound fail.

    Science.gov (United States)

    Lubina, Nóra; Schedelbeck, Ulla; Roth, Anne; Weng, Andreas Max; Geissinger, Eva; Hönig, Arnd; Hahn, Dietbert; Bley, Thorsten Alexander

    2015-05-01

    To compare 3.0 Tesla breast magnetic resonance imaging (MRI) with galactography for detection of benign and malignant causes of nipple discharge in patients with negative mammography and ultrasound. We prospectively evaluated 56 breasts of 50 consecutive patients with nipple discharge who had inconspicuous mammography and ultrasound, using 3.0 Tesla breast MRI with a dedicated 16-channel breast coil, and then compared the results with galactography. Histopathological diagnoses and follow-ups were used as reference standard. Lesion size estimated on MRI was compared with the size at histopathology. Sensitivity and specificity of MRI vs. galactography for detecting pathologic findings were 95.7 % vs. 85.7 % and 69.7 % vs. 33.3 %, respectively. For the supposed concrete pathology based on MRI findings, the specificity was 67.6 % and the sensitivity 77.3 % (PPV 60.7 %, NPV 82.1 %). Eight malignant lesions were detected (14.8 %). The estimated size at breast MRI showed excellent correlation with the size at histopathology (Pearson's correlation coefficient 0.95, p 3.0 Tesla is an accurate imaging test and can replace galactography in the workup of nipple discharge in patients with inconspicuous mammography and ultrasound. • Breast MRI is an excellent diagnostic tool for patients with nipple discharge. • MRI of the breast reveals malignant lesions despite inconspicuous mammography and ultrasound. • MRI of the breast has greater sensitivity and specificity than galactography. • Excellent correlation of lesion size measured at MRI and histopathology was found.

  2. Technical procedures for implementation of background environmental radioactivity site studies, Deaf Smith County site, Texas: Environmental Field Program: Preliminary draft

    International Nuclear Information System (INIS)

    1987-09-01

    The purpose of this technical procedure is to describe the method for performing field maintenance on low-volume air samplers and the associated topics of personnel and organization, procedure preparation, documentation, and quality assurance. The scope of this procedure includes the maintenance of low-volume air samplers in the field and does not encompass maintenance performed by the manufacturer

  3. BOLD cardiovascular magnetic resonance at 3.0 tesla in myocardial ischemia.

    Science.gov (United States)

    Manka, Robert; Paetsch, Ingo; Schnackenburg, Bernhard; Gebker, Rolf; Fleck, Eckart; Jahnke, Cosima

    2010-09-22

    The purpose of this study was to determine the ability of blood oxygen level dependent (BOLD) cardiovascular magnetic resonance (CMR) to detect stress-inducible myocardial ischemic reactions in the presence of angiographically significant coronary artery disease (CAD). Forty-six patients (34 men; age 65 ± 9 years,) with suspected or known coronary artery disease underwent CMR at 3Tesla prior to clinically indicated invasive coronary angiography. BOLD CMR was performed in 3 short axis slices of the heart at rest and during adenosine stress (140 μg/kg/min) followed by late gadolinium enhancement (LGE) imaging. In all 16 standard myocardial segments, T2* values were derived at rest and under adenosine stress. Quantitative coronary angiography served as the standard of reference and defined normal myocardial segments (i.e. all 16 segments in patients without any CAD), ischemic segments (i.e. supplied by a coronary artery with ≥50% luminal narrowing) and non-ischemic segments (i.e. supplied by a non-significantly stenosed coronary artery in patients with significant CAD). Coronary angiography demonstrated significant CAD in 23 patients. BOLD CMR at rest revealed significantly lower T2* values for ischemic segments (26.7 ± 11.6 ms) compared to normal (31.9 ± 11.9 ms; p BOLD CMR at 3Tesla proved feasible and differentiated between ischemic, non-ischemic, and normal myocardial segments in a clinical patient population. BOLD CMR during vasodilator stress identified patients with significant CAD.

  4. Test Results of HD1b, an upgraded 16 Tesla Nb3Sn Dipole Magnet

    International Nuclear Information System (INIS)

    Lietzke, A.F.; Bartlett, S.E.; Bish, P.; Caspi, S.; Dietderich, D.; Ferracin, P.; Gourlay, S.; Hafalia, A.R.; Hannaford, C.R.; Higley, H.; Lau, W.; Liggins, N.; Mattafirri, S.; Nyman, M.; Sabbi, G.; Scanlan, R.; Swanson, J.

    2005-01-01

    The Superconducting Magnet Group at Lawrence Berkeley National Laboratory has been developing high-field, brittle-superconductor, accelerator magnet technology, in which the conductor's support system can significantly impact conductor performance (as well as magnet training). A recent H-dipole coil test (HD1) achieved a peak bore-field of 16 Tesla, using two, flat-racetrack, double-layer Nb 3 Sn coils. However, its 4.5 K training was slow, with an erratic plateau at ∼92% of its un-degraded ''short-sample'' expectation (∼16.6 T). Quench-origins correlated with regions where low conductor pre-stress had been expected (3-D FEM predictions and variations in 300 K coil-size). The coils were re-assembled with minor coil-support changes and re-tested as ''HD1b'', with a 185 MPa average pre-stress (30 MPa higher than HD1, with a 15-20 MPa pole-turn margin expected at 17 T). Training started higher (15.1 T), and quickly reached a stable, negligibly higher plateau at 16 T. After a thermal cycle, training started at 15.4 T, but peaked at 15.8 T, on the third attempt, before degrading to a 15.7 T plateau. The temperature dependence of this plateau was explored in a sub-atmospheric LHe bath to 3.0 K. Magnet performance data for both thermal cycles is presented and discussed, along with issues for future high-field accelerator magnet development

  5. Biological effects of electromagnetic fields and recently updated safety guidelines for strong static magnetic fields

    International Nuclear Information System (INIS)

    Yamaguchi-Sekino, Sachiko; Sekino, Masaki; Ueno, Shoogo

    2011-01-01

    Humans are exposed daily to artificial and naturally occurring magnetic fields that originate from many different sources. We review recent studies that examine the biological effects of and medical applications involving electromagnetic fields, review the properties of static and pulsed electromagnetic fields that affect biological systems, describe the use of a pulsed electromagnetic field in combination with an anticancer agent as an example of a medical application that incorporates an electromagnetic field, and discuss the recently updated safety guidelines for static electromagnetic fields. The most notable modifications to the 2009 International Commission on Non-Ionizing Radiation Protection guidelines are the increased exposure limits, especially for those who work with or near electromagnetic fields (occupational exposure limits). The recommended increases in exposure were determined using recent scientific evidence obtained from animal and human studies. Several studies since the 1994 publication of the guidelines have examined the effects on humans after exposure to high static electromagnetic fields (up to 9.4 tesla), but additional research is needed to ascertain further the safety of strong electromagnetic fields. (author)

  6. Technical procedures for implementation of acoustics site studies, Deaf Smith County site, Texas: Environmental Field Program: Preliminary draft

    International Nuclear Information System (INIS)

    1987-09-01

    The purpose and scope of the technical procedure for processing data from the tethered meteorological system are covered. Definitions, interfaces, and concurrent data needs are also addressed. This technical procedure describes how to control, organize, verify, and archive tethered meteorological system data. These data will be received at the processing location from the field measurement location and are part of the characterization of the Deaf Smith County Site, Texas for the salt repository program. These measurements will be made in support of the sound propagation study and are a result of environmental data requirements for acoustics. 6 refs., 15 figs., 5 tabs

  7. Toward imaging the body at 10.5 tesla.

    Science.gov (United States)

    Ertürk, M Arcan; Wu, Xiaoping; Eryaman, Yiğitcan; Van de Moortele, Pierre-François; Auerbach, Edward J; Lagore, Russell L; DelaBarre, Lance; Vaughan, J Thomas; Uğurbil, Kâmil; Adriany, Gregor; Metzger, Gregory J

    2017-01-01

    To explore the potential of performing body imaging at 10.5 Tesla (T) compared with 7.0T through evaluating the transmit/receive performance of similarly configured dipole antenna arrays. Fractionated dipole antenna elements for 10.5T body imaging were designed and evaluated using numerical simulations. Transmit performance of antenna arrays inside the prostate, kidneys and heart were investigated and compared with those at 7.0T using both phase-only radiofrequency (RF) shimming and multi-spoke pulses. Signal-to-noise ratio (SNR) comparisons were also performed. A 10-channel antenna array was constructed to image the abdomen of a swine at 10.5T. Numerical methods were validated with phantom studies at both field strengths. Similar power efficiencies were observed inside target organs with phase-only shimming, but RF nonuniformity was significantly higher at 10.5T. Spokes RF pulses allowed similar transmit performance with accompanying local specific absorption rate increases of 25-90% compared with 7.0T. Relative SNR gains inside the target anatomies were calculated to be >two-fold higher at 10.5T, and 2.2-fold SNR gain was measured in a phantom. Gradient echo and fast spin echo imaging demonstrated the feasibility of body imaging at 10.5T with the designed array. While comparable power efficiencies can be achieved using dipole antenna arrays with static shimming at 10.5T; increasing RF nonuniformities underscore the need for efficient, robust, and safe parallel transmission methods. Magn Reson Med 77:434-443, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  8. Amide Proton Transfer Magnetic Resonance Imaging of Alzheimer′s Disease at 3.0 Tesla: A Preliminary Study

    Directory of Open Access Journals (Sweden)

    Rui Wang

    2015-01-01

    Full Text Available Background: Amide proton transfer (APT imaging has recently emerged as an important contrast mechanism for magnetic resonance imaging (MRI in the field of molecular and cellular imaging. The aim of this study was to evaluate the feasibility of APT imaging to detect cerebral abnormality in patients with Alzheimer′s disease (AD at 3.0 Tesla. Methods: Twenty AD patients (9 men and 11 women; age range, 67-83 years and 20 age-matched normal controls (11 men and 9 women; age range, 63-82 years underwent APT and traditional MRI examination on a 3.0 Tesla MRI system. The magnetic resonance ratio asymmetry (MTR asym values at 3.5 ppm of bilateral hippocampi (Hc, temporal white matter regions, occipital white matter regions, and cerebral peduncles were measured on oblique axial APT images. MTR asym (3.5 ppm values of the cerebral structures between AD patients and control subjects were compared with independent samples t-test. Controlling for age, partial correlation analysis was used to investigate the associations between mini-mental state examination (MMSE and the various MRI measures among AD patients. Results: Compared with normal controls, MTR asym (3.5 ppm values of bilateral Hc were significantly increased in AD patients (right 1.24% ± 0.21% vs. 0.83% ± 0.19%, left 1.18% ± 0.18% vs. 0.80%± 0.17%, t = 3.039, 3.328, P = 0.004, 0.002, respectively. MTR asym (3.5 ppm values of bilateral Hc were significantly negatively correlated with MMSE (right r = −0.559, P = 0.013; left r = −0.461, P = 0.047. Conclusions: Increased MTR asym (3.5 ppm values of bilateral Hc in AD patients and its strong correlations with MMSE suggest that APT imaging could potentially provide imaging biomarkers for the noninvasive molecular diagnosis of AD.

  9. Imaging performance of a dedicated radiation transparent RF coil on a 1.0 Tesla inline MRI-linac.

    Science.gov (United States)

    Liney, Gary P; Dong, Bin; Weber, Ewald; Rai, Robba; Destruel, Aurelien; Garcia-Alvarez, Roberto; Manton, David; Jelen, Urszula; Zhang, Kevin; Barton, Michael; Keall, Paul J; Crozier, Stuart

    2018-05-25

    This work describes the first imaging studies on a 1.0 Tesla inline MRI-Linac using a dedicated transmit/receive RF body coil that has been designed to be completely radio transparent and provide optimum imaging performance over a large patient opening. Methods: A series of experiments was performed on the MRI-Linac to investigate the performance and imaging characteristics of a new dedicated volumetric RF coil: (1) numerical electromagnetic simulations were used to measure transmit efficiency in two patient positions; (2) image quality metrics of signal-to-noise ratio (SNR), ghosting and uniformity were assessed in a large diameter phantom with no radiation beam; (3) radiation induced effects were investigated in both the raw data (k-space) and image sequences acquired with simultaneous irradiation; (4) radiation dose was measured with and without image acquisition; (5) RF heating was studied using an MR-compatible fluoroptic thermometer and; (6) the in vivo image quality and versatility of the coil was demonstrated in normal healthy subjects for both supine and standing positions. Results: Daily phantom measurements demonstrated excellent imaging performance with stable SNR over a period of 3 months (42.6 ± 0.9). Simultaneous irradiation produced no statistical change in image quality (p>0.74) and no interference in raw data for a 20  20 cm radiation field. The coil was found to be efficient over large volumes and negligible RF heating was observed. Volunteer scans acquired in both supine and standing positions provided artefact free images with good anatomical visualisation. Conclusions: The first completely radio transparent RF coil for use on a 1.0 Tesla MRI-Linac has been described. There is no impact on either the imaging or dosimetry performance with a simultaneous radiation beam. The open design enables imaging and radiotherapy guidance in a variety of positons. . © 2018 Institute of Physics and Engineering in Medicine.

  10. Magnetic field effects on brain monoamine oxidase activity

    Energy Technology Data Exchange (ETDEWEB)

    Borets, V.M.; Ostrovskiy, V.Yu.; Bankovskiy, A.A.; Dudinskaya, T.F.

    1985-03-01

    In view of the increasing use of magnetotherapy, studies were conducted on the effects of 35 mTesla magnetic fields on monoamine oxidase activity in the rat brain. Under in vitro conditions a constant magnetic field in the continuous mode was most effective in inhibiting deamination of dopamine following 1 min exposure, while in vivo studies with 8 min or 10 day exposures showed that inhibition was obtained only with a variable field in the continuous mode. However, inhibition of dopamine deamination was only evident within the first 24 h after exposure was terminated. In addition, in none of the cases was norepinephrine deamination inhibited. The effects of the magnetic fields were, therefore, transient and selective with the CNS as the target system. 9 references.

  11. Tolerance of magnetic resonance imaging in children and adolescents performed in a 1.5 Tesla MR scanner with an open design

    International Nuclear Information System (INIS)

    Adamietz, B.; Cavallaro, A.; Radkow, T.; Alibek, S.; Bautz, W.A.; Holter, W.; Staatz, G.

    2007-01-01

    Purpose: To investigate the tolerance of MR examinations in children and adolescents performed in a 1.5 Tesla MR scanner with an expanded bore diameter. Method and Materials: 163 patients, ages 4 to 25, underwent MR examinations in a 1.5 Tesla MR scanner with an open design (MAGNETOM Espree, Siemens, Erlangen, Germany), characterized by a compact length of 125 cm and an expanded 70 cm bore diameter. MR imaging of the brain was carried out in most cases (78.5 %), followed by examinations of the spinal canal (9.8 %), the extremities (9.2 %) and the neck (2.5 %). The patients were divided into four age groups and the success rate, motion artifacts and diagnostic quality of the MR examinations were assessed using a 3-grade scale. Results: In 119 of 163 patients (73.0 %), MR examination was possible without any motion artifacts. With respect to the different age groups, 41.7 % of the 4 - 7-year-old children, 67.6 % of the 8 - 10-year-old children, 84.1 % of the 11 - 16-year-old children and 95.8 % of the patients older than 17 showed tolerance grade I without motion artifacts and excellent diagnostic image quality. In 39 of 163 children (23.9 %), the MR images showed moderate motion artifacts but had sufficient diagnostic quality. With regard to the different age groups, 52.8 % of the 4 - 7-year-old children, 26.5 % of the 8 - 10-year-old children, 15.9 % of the 11 - 16-year-old children and none of the patients older than 17 showed tolerance grade II with moderate motion artifacts and sufficient diagnostic image quality. In only 4 of 124 children 10 years old, the MR examination was not feasible and had to be repeated under sedation. Conclusion: Pediatric MR imaging using a 1.5 Tesla MR scanner with an open design can be conducted in children and adolescents with excellent acceptance. The failure rate of 3.0 % of cases for pediatric MR imaging is comparable to that of a conventional low-field open MR scanner. (orig.)

  12. Can magnetic resonance imaging at 3.0-Tesla reliably detect patients with endometriosis? Initial results.

    Science.gov (United States)

    Thomeer, Maarten G; Steensma, Anneke B; van Santbrink, Evert J; Willemssen, Francois E; Wielopolski, Piotr A; Hunink, Myriam G; Spronk, Sandra; Laven, Joop S; Krestin, Gabriel P

    2014-04-01

    The aim of this study was to determine whether an optimized 3.0-Tesla magnetic resonance imaging (MRI) protocol is sensitive and specific enough to detect patients with endometriosis. This was a prospective cohort study with consecutive patients. Forty consecutive patients with clinical suspicion of endometriosis underwent 3.0-Tesla MRI, including a T2-weighted high-resolution fast spin echo sequence (spatial resolution=0.75 ×1.2 ×1.5 mm³) and a 3D T1-weighted high-resolution gradient echo sequence (spatial resolution=0.75 ×1.2 × 2.0 mm³). Two radiologists reviewed the dataset with consensus reading. During laparoscopy, which was used as reference standard, all lesions were characterized according to the revised criteria of the American Fertility Society. Patient-level and region-level sensitivities and specificities and lesion-level sensitivities were calculated. Patient-level sensitivity was 42% for stage I (5/12) and 100% for stages II, III and IV (25/25). Patient-level specificity for all stages was 100% (3/3). The region-level sensitivity and specificity was 63% and 97%, respectively. The sensitivity per lesion was 61% (90% for deep lesions, 48% for superficial lesions and 100% for endometriomata). The detection rate of obliteration of the cul-the-sac was 100% (10/10) with no false positive findings. The interreader agreement was substantial to perfect (kappa=1 per patient, 0.65 per lesion and 0.71 for obliteration of the cul-the-sac). An optimized 3.0-Tesla MRI protocol is accurate in detecting stage II to stage IV endometriosis. © 2014 The Authors. Journal of Obstetrics and Gynaecology Research © 2014 Japan Society of Obstetrics and Gynecology.

  13. Intraoperative 3-tesla MRI in the management of paediatric cranial tumours - initial experience

    International Nuclear Information System (INIS)

    Avula, Shivaram; Garlick, Deborah; Abernethy, Laurence J.; Mallucci, Connor L.; Pizer, Barry; Crooks, Daniel

    2012-01-01

    Intraoperative MRI (ioMRI) has been gaining recognition because of its value in the neurosurgical management of cranial tumours. There is limited documentation of its value in children. To review the initial experience of a paediatric 3-Tesla ioMRI unit in the management of cranial tumours. Thirty-eight children underwent ioMRI during 40 cranial tumour resections using a 3-Tesla MR scanner co-located with the neurosurgical operating theatre. IoMRI was performed to assess the extent of tumour resection and/or to update neuronavigation. The intraoperative and follow-up scans, and the clinical records were reviewed. In 27/40 operations, complete resection was intended. IoMRI confirmed complete resection in 15/27 (56%). As a consequence, surgical resection was extended in 5/27 (19%). In 6/27 (22%), ioMRI was equivocal for residual tumour. In 13/40 (33%) operations, the surgical aim was to partially resect the tumour. In 7 of the 13 (54%), surgical resection was extended following ioMRI. In our initial experience, ioMRI has increased the rate of complete resection, with intraoperative surgical strategy being modified in 30% of procedures. Collaborative analysis of ioMRI by the radiologist and neurosurgeon is vital to avoid errors in interpretation. (orig.)

  14. Intraoperative 3-tesla MRI in the management of paediatric cranial tumours - initial experience

    Energy Technology Data Exchange (ETDEWEB)

    Avula, Shivaram; Garlick, Deborah; Abernethy, Laurence J. [Alder Hey Children' s NHS Foundation Trust, Department of Radiology, Liverpool (United Kingdom); Mallucci, Connor L. [Alder Hey Children' s Hospital, Department of Neurosurgery, Liverpool (United Kingdom); Pizer, Barry [Alder Hey Children' s Hospital, Department of Oncology, Liverpool (United Kingdom); Crooks, Daniel [Walton Centre for Neurology and Neurosurgery, Department of Pathology, Liverpool (United Kingdom)

    2012-02-15

    Intraoperative MRI (ioMRI) has been gaining recognition because of its value in the neurosurgical management of cranial tumours. There is limited documentation of its value in children. To review the initial experience of a paediatric 3-Tesla ioMRI unit in the management of cranial tumours. Thirty-eight children underwent ioMRI during 40 cranial tumour resections using a 3-Tesla MR scanner co-located with the neurosurgical operating theatre. IoMRI was performed to assess the extent of tumour resection and/or to update neuronavigation. The intraoperative and follow-up scans, and the clinical records were reviewed. In 27/40 operations, complete resection was intended. IoMRI confirmed complete resection in 15/27 (56%). As a consequence, surgical resection was extended in 5/27 (19%). In 6/27 (22%), ioMRI was equivocal for residual tumour. In 13/40 (33%) operations, the surgical aim was to partially resect the tumour. In 7 of the 13 (54%), surgical resection was extended following ioMRI. In our initial experience, ioMRI has increased the rate of complete resection, with intraoperative surgical strategy being modified in 30% of procedures. Collaborative analysis of ioMRI by the radiologist and neurosurgeon is vital to avoid errors in interpretation. (orig.)

  15. 49 CFR 845.22 - Technical panel.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 7 2010-10-01 2010-10-01 false Technical panel. 845.22 Section 845.22... Technical panel. The Director, Bureau of Accident Investigation, or the Director, Bureau of Field Operations, shall designate members of the Board's technical staff to participate in the hearing and initially...

  16. Noninvasive Assessment of Oxygen Extraction Fraction in Chronic Ischemia Using Quantitative Susceptibility Mapping at 7 Tesla.

    Science.gov (United States)

    Uwano, Ikuko; Kudo, Kohsuke; Sato, Ryota; Ogasawara, Kuniaki; Kameda, Hiroyuki; Nomura, Jun-Ichi; Mori, Futoshi; Yamashita, Fumio; Ito, Kenji; Yoshioka, Kunihiro; Sasaki, Makoto

    2017-08-01

    The oxygen extraction fraction (OEF) is an effective metric to evaluate metabolic reserve in chronic ischemia. However, OEF is considered to be accurately measured only when using positron emission tomography (PET). Thus, we investigated whether OEF maps generated by magnetic resonance quantitative susceptibility mapping (QSM) at 7 Tesla enabled detection of OEF changes when compared with those obtained with PET. Forty-one patients with chronic stenosis/occlusion of the unilateral internal carotid artery or middle cerebral artery were examined using 7 Tesla-MRI and PET scanners. QSM images were obtained from 3-dimensional T2*-weighted images, using a multiple dipole-inversion algorithm. OEF maps were generated based on susceptibility differences between venous structures and brain tissues on QSM images. OEF ratios of the ipsilateral middle cerebral artery territory against the contralateral side were calculated on the QSM-OEF and PET-OEF images, using an anatomic template. The OEF ratio in the middle cerebral artery territory showed significant correlations between QSM-OEF and PET-OEF maps ( r =0.69; P 1.09, as determined by receiver operating characteristic analysis, showed a sensitivity and specificity of 0.82 and 0.86, respectively, for the substantial increase in the PET-OEF ratio. Absolute QSM-OEF values were significantly correlated with PET-OEF values in the patients with increased PET-OEF. OEF ratios on QSM-OEF images at 7 Tesla showed a good correlation with those on PET-OEF images in patients with unilateral steno-occlusive internal carotid artery/middle cerebral artery lesions, suggesting that noninvasive OEF measurement by MRI can be a substitute for PET. © 2017 American Heart Association, Inc.

  17. Minimizing magnetic fields for precision experiments

    Energy Technology Data Exchange (ETDEWEB)

    Altarev, I.; Fierlinger, P.; Lins, T.; Marino, M. G.; Nießen, B.; Petzoldt, G.; Reisner, M.; Stuiber, S., E-mail: stefan.stuiber@ph.tum.de; Sturm, M.; Taggart Singh, J.; Taubenheim, B. [Physikdepartment, Technische Universität München, D-85748 Garching (Germany); Rohrer, H. K. [Rohrer GmbH, D-80667 München (Germany); Schläpfer, U. [IMEDCO AG, CH-4614 Hägendorf (Switzerland)

    2015-06-21

    An increasing number of measurements in fundamental and applied physics rely on magnetically shielded environments with sub nano-Tesla residual magnetic fields. State of the art magnetically shielded rooms (MSRs) consist of up to seven layers of high permeability materials in combination with highly conductive shields. Proper magnetic equilibration is crucial to obtain such low magnetic fields with small gradients in any MSR. Here, we report on a scheme to magnetically equilibrate MSRs with a 10 times reduced duration of the magnetic equilibration sequence and a significantly lower magnetic field with improved homogeneity. For the search of the neutron's electric dipole moment, our finding corresponds to a 40% improvement of the statistical reach of the measurement. However, this versatile procedure can improve the performance of any MSR for any application.

  18. Minimizing magnetic fields for precision experiments

    International Nuclear Information System (INIS)

    Altarev, I.; Fierlinger, P.; Lins, T.; Marino, M. G.; Nießen, B.; Petzoldt, G.; Reisner, M.; Stuiber, S.; Sturm, M.; Taggart Singh, J.; Taubenheim, B.; Rohrer, H. K.; Schläpfer, U.

    2015-01-01

    An increasing number of measurements in fundamental and applied physics rely on magnetically shielded environments with sub nano-Tesla residual magnetic fields. State of the art magnetically shielded rooms (MSRs) consist of up to seven layers of high permeability materials in combination with highly conductive shields. Proper magnetic equilibration is crucial to obtain such low magnetic fields with small gradients in any MSR. Here, we report on a scheme to magnetically equilibrate MSRs with a 10 times reduced duration of the magnetic equilibration sequence and a significantly lower magnetic field with improved homogeneity. For the search of the neutron's electric dipole moment, our finding corresponds to a 40% improvement of the statistical reach of the measurement. However, this versatile procedure can improve the performance of any MSR for any application

  19. Silver doped hydroxyapatite coatings by sacrificial anode deposition under magnetic field.

    Science.gov (United States)

    Swain, S; Rautray, T R

    2017-09-13

    Uniform distribution of silver (Ag) in the hydroxyapatite (HA) coated Ti surface has been a concern for which an attempt has been made to dope Ag in HA coating with and without magnetic field. Cathodic deposition technique was employed to coat Ag incorporated hydroxyapatite coating using a sacrificial silver anode method by using NdFeB bar magnets producing 12 Tesla magnetic field. While uniform deposition of Ag was observed in the coatings under magnetic field, dense coating was evident in the coating without magnetic field conditions. Uniformly distributed Ag incorporated HA in the present study has potential to fight microorganism while providing osseoconduction properties of the composite coating.

  20. Quadrature transmit coil for breast imaging at 7 tesla using forced current excitation for improved homogeneity.

    Science.gov (United States)

    McDougall, Mary Preston; Cheshkov, Sergey; Rispoli, Joseph; Malloy, Craig; Dimitrov, Ivan; Wright, Steven M

    2014-11-01

    To demonstrate the use of forced current excitation (FCE) to create homogeneous excitation of the breast at 7 tesla, insensitive to the effects of asymmetries in the electrical environment. FCE was implemented on two breast coils: one for quadrature (1) H imaging and one for proton-decoupled (13) C spectroscopy. Both were a Helmholtz-saddle combination, with the saddle tuned to 298 MHz for imaging and 75 MHz for spectroscopy. Bench measurements were acquired to demonstrate the ability to force equal currents on elements in the presence of asymmetric loading to improve homogeneity. Modeling and temperature measurements were conducted per safety protocol. B1 mapping, imaging, and proton-decoupled (13) C spectroscopy were demonstrated in vivo. Using FCE to ensure balanced currents on elements enabled straightforward tuning and maintaining of isolation between quadrature elements of the coil. Modeling and bench measurements confirmed homogeneity of the field, which resulted in images with excellent fat suppression and in broadband proton-decoupled carbon-13 spectra. FCE is a straightforward approach to ensure equal currents on multiple coil elements and a homogeneous excitation field, insensitive to the effects of asymmetries in the electrical environment. This enabled effective breast imaging and proton-decoupled carbon-13 spectroscopy at 7T. © 2014 Wiley Periodicals, Inc.