  1. Design and development of microblaze processor based Remote Terminal Units for Fast Breeder Reactors

    International Nuclear Information System (INIS)

    Gour, Aditya; Santhanaraj, A.; Behera, R.P.; Murali, N.; Satyamurty, S.A.V.

    2013-01-01

    Remote Terminal Units (RTUs) are single board remote data acquisition and control systems that are widely used in FBRs during all states of plant operation. Distributed Digital Control System (DDCS) architecture is being followed for the plant control and operation, which mandates the need for multiple sockets support in TCPIP Ethernet communication in an embedded system. Existing RTUs are 89C51 microcontroller based systems where the TCPIP communication is done using Wiznet Module. These modules can support maximum of four sockets and are already obsolete from the market. In this paper a new RTU design is described where the complete digital logic of a board is implemented in one single FPGA device using Soft-core processor and EMAC controller with multiple socket support for the Ethernet communication. This makes design more reliable and immune to obsolescence. (author)

  2. Field Evaluation of the Performance of the RTU Challenge Unit: Daikin Rebel

    Energy Technology Data Exchange (ETDEWEB)

    Katipamula, Srinivas [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Wang, W. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Ngo, Hung [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Underhill, Ronald M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2017-05-31

    Packaged rooftop air-conditioning units (RTUs) are used in 44% (2.5 million) of all commercial buildings, serving over 57% (46 billion square feet) of the commercial building floor space in the United States (EIA 2012). The primary energy consumption associated with RTUs is over 2.2 quads annually. Therefore, even a small improvement in efficiency or part-load operation of these units can lead to significant reductions in energy use and carbon emissions. Starting in 2011, the U.S. Department of Energy’s (DOE’s) Building Technologies Office funded a series of projects related to RTUs. Some projects were intended to improve the operating efficiency of the existing RTUs, while others were focused on improving the operating efficiency of new units. This report documents the field-testing and comparison of the seasonal efficiency of a state-of-art RTU Challenge unit and a standard unit. Section II provides the background for the work. Section III describes the measurement and verification plan for the field tests. Section IV describes the measurement and verification evaluation plan. The results are described in Section V. The lessons learned and recommendations for future work are presented in Section VI. A list of references is provided in Section VII.

  3. Development of a supervisory control and data acquisitioning system

    International Nuclear Information System (INIS)

    Kamboh, A.M.; Fakhar, H.A.; Rafiq, G.; Kazmi, S.R.

    2004-01-01

    This paper describes a Supervisory Control and Data Acquisitioning system called SCADA that we have developed at NUST. This research is aimed at the development of a network where a central Control Server extends bidirectional data exchange capability to hundreds of geographically remote sensors and actuators spread over a distance greater than 3 Km. Several battery-driven handheld terminals called Remote Terminal Units (RTU) have been designed to provide both wired and wireless connectivity between sensors and the network, also adding limited mobility to the sensors. Simple transceivers give the RTUs wireless access to network. The Human-Machine Intel (HMI) for the RTUs and the Server have been provided. A repeater has also been designed to increase the number of RTUs connected, and the maximum allowed distance between units and the server. The wired network gives several times faster connectivity than the wireless network, in addition to the larger area covered, but at the cost of mobility. (author)

  4. Termination unit

    Energy Technology Data Exchange (ETDEWEB)

    Traeholt, Chresten; Willen, Dag; Roden, Mark; Tolbert, Jerry C.; Lindsay, David; Fisher, Paul W.; Nielsen, Carsten Thidemann

    2016-05-03

    Cable end section comprises end-parts of N electrical phases/neutral, and a thermally-insulation envelope comprising cooling fluid. The end-parts each comprises a conductor and are arranged with phase 1 innermost, N outermost surrounded by the neutral, electrical insulation being between phases and N and neutral. The end-parts comprise contacting surfaces located sequentially along the longitudinal extension of the end-section. A termination unit has an insulating envelope connected to a cryostat, special parts at both ends comprising an adapter piece at the cable interface and a closing end-piece terminating the envelope in the end-section. The special parts houses an inlet and/or outlet for cooling fluid. The space between an inner wall of the envelope and a central opening of the cable is filled with cooling fluid. The special part at the end connecting to the cryostat houses an inlet or outlet, splitting cooling flow into cable annular flow and termination annular flow.

  5. Willowglen Systems Inc. : 8 case studies

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2010-07-01

    The various supervisory control and data acquisition (SCADA) systems designed by Willowglen Systems Inc. were described. The company provides custom SCADA technology products, automation systems, and technical services for various applications. Their remote terminal units (RTUs) were designed to have a very low power consumption rate, and can be operated from any power source. The company has also designed integrated metering and communications solutions for remote locations. The following 8 case studies of Willowglen System solutions were highlighted: (1) a SCADA system designed for the Northwest Territories Power Corporation, (2) a system of RTUs installed at the Shell Canada Ltd. Caroline Gas Complex, (3) a SCADA system designed to monitor a natural gas pipeline, (4) a SCADA system designed to monitor a transmission pipeline and distribution system in Singapore, (5) RTUs designed to monitor gas dehydration units in Bahrain, (6) a SCADA system designed for a refined petroleum products pipeline, (7) a SCADA system installed at an electric power utility in New Brunswick, and (8) a tank gauging system designed for a large oil refinery in Alberta. 7 figs.

  6. Development of a Hydronic Rooftop Unit-HyPak-MA

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Eric; Berman, Mark

    2009-11-14

    The majority of U.S. commercial floor space is cooled by rooftop HVAC units (RTUs). RTU popularity derives chiefly from their low initial cost and relative ease of service access without disturbing building occupants. Unfortunately, current RTUs are inherently inefficient due to a combination of characteristics that unnecessarily increase cooling loads and energy use. 36% percent of annual U.S. energy, and two-thirds of electricity, is consumed in and by buildings. Commercial buildings consume approximately 4.2 quads of energy each year at a cost of $230 billion per year, with HVAC equipment consuming 1.2 quads of electricity. More than half of all U.S. commercial floor space is cooled by packaged HVAC units, most of which are rooftop units (RTUs). Inefficient RTUs create an estimated 3.5% of U.S. CO{sub 2} emissions, thus contributing significantly to global warming5. Also, RTUs often fail to maintain adequate ventilation air and air filtration, reducing indoor air quality. This is the second HyPak project to be supported by DOE through NETL. The prior project, referred to as HyPak-1 in this report, had two rounds of prototype fabrication and testing as well as computer modeling and market research. The HyPak-1 prototypes demonstrated the high performance capabilities of the HyPak concept, but made it clear that further development was required to reduce heat exchanger cost and improve system reliability before HyPak commercialization can commence. The HyPak-1 prototypes were limited to about 25% ventilation air fraction, limiting performance and marketability. The current project is intended to develop a 'mixed-air' product that is capable of full 0-100% modulation in ventilation air fraction, hence it was referred to as HyPak-MA in the proposal. (For simplicity, the -MA has been dropped when referencing the current project.) The objective of the HyPak Project is to design, develop and test a hydronic RTU that provides a quantum improvement over

  7. RM12-2703 Advanced Rooftop Unit Control Retrofit Kit Field Demonstration: Hawaii and Guam Energy Improvement Technology Demonstration Project

    Energy Technology Data Exchange (ETDEWEB)

    Doebber, I. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Dean, J. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Dominick, J. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Holland, G. [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2014-03-01

    As part of its overall strategy to meet its energy goals, the Naval Facilities Engineering Command (NAVFAC) partnered with U.S. Department of Energy's (DOE) National Renewable Energy Laboratory (NREL) to rapidly demonstrate and deploy cost-effective renewable energy and energy efficiency technologies. This was one of several demonstrations of new and underutilized commercial energy efficiency technologies. The consistent year-round demand for air conditioning and dehumidification in Hawaii provides an advantageous demonstration location for advanced rooftop control (ARC) retrofit kits to packaged rooftop units (RTUs). This report summarizes the field demonstration of ARCs installed on nine RTUs serving a 70,000-ft2 exchange store (large retail) and two RTUs, each serving small office buildings located on Joint Base Pearl Harbor-Hickam (JBPHH).

  8. 24 CFR 982.403 - Terminating HAP contract when unit is too small.

    Science.gov (United States)

    2010-04-01

    ... 24 Housing and Urban Development 4 2010-04-01 2010-04-01 false Terminating HAP contract when unit... Terminating HAP contract when unit is too small. (a) Violation of HQS space standards. (1) If the PHA... by the family, the PHA must terminate the HAP contract in accordance with its terms. (b) Certificate...

  9. Termination unit

    Science.gov (United States)

    Traeholt, Chresten [Frederiksberg, DK; Willen, Dag [Klagshamn, SE; Roden, Mark [Newnan, GA; Tolbert, Jerry C [Carrollton, GA; Lindsay, David [Carrollton, GA; Fisher, Paul W [Heiskell, TN; Nielsen, Carsten Thidemann [Jaegerspris, DK

    2014-01-07

    This invention relates to a termination unit comprising an end-section of a cable. The end section of the cable defines a central longitudinal axis and comprising end-parts of N electrical phases, an end-part of a neutral conductor and a surrounding thermally insulation envelope adapted to comprising a cooling fluid. The end-parts of the N electrical phases and the end-part of the neutral conductor each comprising at least one electrical conductor and being arranged in the cable concentrically around a core former with a phase 1 located relatively innermost, and phase N relatively outermost in the cable, phase N being surrounded by the neutral conductor, electrical insulation being arrange between neighboring electrical phases and between phase N and the neutral conductor, and wherein the end-parts of the neutral conductor and the electrical phases each comprise a contacting surface electrically connected to at least one branch current lead to provide an electrical connection: The contacting surfaces each having a longitudinal extension, and being located sequentially along the longitudinal extension of the end-section of the cable. The branch current leads being individually insulated from said thermally insulation envelope by individual electrical insulators.

  10. 77 FR 30584 - Notice of Termination of United States-Bolivia Bilateral Investment Treaty

    Science.gov (United States)

    2012-05-23

    ... of Termination of United States--Bolivia Bilateral Investment Treaty AGENCY: Department of State and Office of the United States Trade Representative. ACTION: Notice. SUMMARY: The Government of Bolivia has...-9580. SUPPLEMENTARY INFORMATION: Bolivia delivered notice on June 10, 2011, that it was terminating the...

  11. Power system SCADA and smart grids

    CERN Document Server

    Thomas, Mini S

    2015-01-01

    Power System SCADA and Smart Grids brings together in one concise volume the fundamentals and possible application functions of power system supervisory control and data acquisition (SCADA). The text begins by providing an overview of SCADA systems, evolution, and use in power systems and the data acquisition process. It then describes the components of SCADA systems, from the legacy remote terminal units (RTUs) to the latest intelligent electronic devices (IEDs), data concentrators, and master stations, as well as:Examines the building and practical implementation of different SCADA systemsOf

  12. IEA EBC Annex 59 - Possibilities, limitations and capacities of indoor terminal units

    DEFF Research Database (Denmark)

    Kazanci, Ongun Berk; Olesen, Bjarne W.

    2015-01-01

    Indoor terminal units can be defined as the building elements that use different heat transfer mechanisms and media to emit and remove heat or moisture from indoor spaces (e.g. hydronic radiant heating and cooling systems, fan-coil units, active beams). Indoor temperature and humidity fields depe...

  13. Justification of the project a network of freight terminals unitized cargo

    Directory of Open Access Journals (Sweden)

    Ilesaliev D.I.

    2016-12-01

    Full Text Available In this paper we consider the question of Uzbekistan in promoting the development of international transport in supply chains. The development of transport infrastructure to ensure timely delivery of goods is one of the main tasks in supply chain management. The aim is to study of the project network terminal unitized cargo Uzbekistan in supply chains. Methods the study is based on analysis of existing methods and techniques of Russian scientists in the field of place-ment of objects. The method of searching the most rational location of logistics facility in the supply chain. Also pre-justified the project network terminal unitized cargo in Uzbekistan. Given the state of the problems and prospects of transport logistics of Uzbekistan, the developed method can be used by experts when performing the supporting calcula-tions location of logistic objects.

  14. Development of Softcore Processor based RTU for FBR

    International Nuclear Information System (INIS)

    Gour, Aditya; Santhana Raj, A.; Behera, R.P.; Murali, N.; Swaminathan, P.

    2010-01-01

    Remote Terminal Units (RTU) are used to acquire analog/digital signals and generate potential free contact outputs and send the acquired data through LAN. The aim of this design is to develop a Soft-Core Processor based RTU by implementing the glue logic along with 8051 microcontroller present in existing RTUs into a single FPGA, so that component count and power consumption on the board will be reduced and thereby achieving a higher reliability than before. Implementation of glue logic was done using VHDL and Altium's TSK51 Softcore was used in place of 8051 microcontroller. (author)

  15. 75 FR 11936 - Unit Structures LLC, Magnolia, AR; Notice of Termination of Investigation

    Science.gov (United States)

    2010-03-12

    ... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-70,367] Unit Structures LLC, Magnolia, AR; Notice of Termination of Investigation Pursuant to Section 223 of the Trade Act of 1974, as... Arkansas Rapid Response Coordinator on behalf of workers of Unit Structures LLC, Magnolia, Arkansas. The...

  16. United States National Waste Terminal Storage argillaceous rock studies

    International Nuclear Information System (INIS)

    Brunton, G.D.

    1981-01-01

    The past and present argillaceous rock studies for the US National Waste Terminal Storage Program consist of: (1) evaluation of the geological characteristics of several widespread argillaceous formations in the United States; (2) laboratory studies of the physical and chemical properties of selected argillaceous rock samples; and (3) two full-scale in situ surface heater experiments that simulate the emplacement of heat-generating radioactive waste in argillaceous rock

  17. United States National Waste Terminal Storage argillaceous rock studies

    International Nuclear Information System (INIS)

    Brunton, G.D.

    1979-01-01

    The past and present argillaceous rock studies for the US National Waste Terminal Storage Program consist of: (1) evaluation of the geological characteristics of several widespread argillaceous formations in the United States; (2) laboratory studies of the physical and chemical properties of selected argillaceous rock samples; and (3) two full-scale in-situ surface heater experiments that simulate the emplacement of heat-generating radioactive waste in argillaceous rock

  18. No Exit: Identifying Avoidable Terminal Oncology Intensive Care Unit Hospitalizations

    Science.gov (United States)

    Hantel, Andrew; Wroblewski, Kristen; Balachandran, Jay S.; Chow, Selina; DeBoer, Rebecca; Fleming, Gini F.; Hahn, Olwen M.; Kline, Justin; Liu, Hongtao; Patel, Bhakti K.; Verma, Anshu; Witt, Leah J.; Fukui, Mayumi; Kumar, Aditi; Howell, Michael D.; Polite, Blase N.

    2016-01-01

    Purpose: Terminal oncology intensive care unit (ICU) hospitalizations are associated with high costs and inferior quality of care. This study identifies and characterizes potentially avoidable terminal admissions of oncology patients to ICUs. Methods: This was a retrospective case series of patients cared for in an academic medical center’s ambulatory oncology practice who died in an ICU during July 1, 2012 to June 30, 2013. An oncologist, intensivist, and hospitalist reviewed each patient’s electronic health record from 3 months preceding terminal hospitalization until death. The primary outcome was the proportion of terminal ICU hospitalizations identified as potentially avoidable by two or more reviewers. Univariate and multivariate analysis were performed to identify characteristics associated with avoidable terminal ICU hospitalizations. Results: Seventy-two patients met inclusion criteria. The majority had solid tumor malignancies (71%), poor performance status (51%), and multiple encounters with the health care system. Despite high-intensity health care utilization, only 25% had documented advance directives. During a 4-day median ICU length of stay, 81% were intubated and 39% had cardiopulmonary resuscitation. Forty-seven percent of these hospitalizations were identified as potentially avoidable. Avoidable hospitalizations were associated with factors including: worse performance status before admission (median 2 v 1; P = .01), worse Charlson comorbidity score (median 8.5 v 7.0, P = .04), reason for hospitalization (P = .006), and number of prior hospitalizations (median 2 v 1; P = .05). Conclusion: Given the high frequency of avoidable terminal ICU hospitalizations, health care leaders should develop strategies to prospectively identify patients at high risk and formulate interventions to improve end-of-life care. PMID:27601514

  19. Study on New Smart Transformer Terminal Unit Based on ARM and GPRS Network

    Directory of Open Access Journals (Sweden)

    Na Wu

    2013-12-01

    Full Text Available Distribution transformer is one of the most important power equipments in distribution network, whose running state exercises a great influence on the stability of the network. Transformer Terminal Unit (TTU is an effective device to monitor the running state of transformers in the distribution automation system. In this paper, we study a new smart TTU which uses ARM7 series chip as processor, equipped with ATT7022B based electric meter module and GPRS module for remote data transmission control. We focus on the corresponding hardware, software design and the measurement principle of harmonics of TTU. The new TTU can measure the electric parameters of the distribution transformer precisely. Taking advantage of the powerful ARM processor, it can analyze harmonic of the power line effectively. Due to the always-on-line feature of GPRS, TTU can achieve reliable communication with the remote terminal and the master station. Compared with other similar units, the new unit outperforms in terms of real-time, precision and reliability, which can fully meet with the high-speed development of distribution automation system.

  20. Intrinsic terminators in Mycoplasma hyopneumoniae transcription.

    Science.gov (United States)

    Fritsch, Tiago Ebert; Siqueira, Franciele Maboni; Schrank, Irene Silveira

    2015-04-08

    Mycoplasma hyopneumoniae, an important pathogen of swine, exhibits a low guanine and cytosine (GC) content genome. M. hyopneumoniae genome is organised in long transcriptional units and promoter sequences have been mapped upstream of all transcription units. These analysis provided insights into the gene organisation and transcription initiation at the genome scale. However, the presence of transcriptional terminator sequences in the M. hyopneumoniae genome is poorly understood. In silico analyses demonstrated the presence of putative terminators in 82% of the 33 monocistronic units (mCs) and in 74% of the 116 polycistronic units (pCs) considering different classes of terminators. The functional activity of 23 intrinsic terminators was confirmed by RT-PCR and qPCR. Analysis of all terminators found by three software algorithms, combined with experimental results, allowed us to propose a pattern of RNA hairpin formation during the termination process and to predict the location of terminators in the M. hyopneumoniae genome sequence. The stem-loop structures of intrinsic terminators of mycoplasma diverge from the pattern of terminators found in other bacteria due the low content of guanine and cytosine. In M. hyopneumoniae, transcription can end after a transcriptional unit and before its terminator sequence and can also continue past the terminator sequence with RNA polymerases gradually releasing the RNA.

  1. Effect of nutritional support on terminally ill patients with cancer in a palliative care unit.

    Science.gov (United States)

    Amano, Koji; Morita, Tatsuya; Baba, Mika; Kawasaki, Muneyoshi; Nakajima, Shinichiro; Uemura, Minako; Kobayashi, Yuka; Hori, Moeko; Wakayama, Hiroshi

    2013-11-01

    The role of nutritional support on terminally ill patients with cancer in a palliative care unit has not been clarified. A total of 63 patients were retrospectively investigated; the patients receiving individualized nutritional support (intervention group [n = 22]) were compared to the others (control group [n = 41]). The intervention group received individualized nutritional support. There were no significant differences in the characteristics of patients between the groups. The prevalence of bedsores was significantly lower in the intervention group (14% vs 46%, P = .012). The prevalence of edema and the use of antibiotic therapies tended to be lower in the intervention group than in the control group (36% vs 54%, P = .19; 14% vs 27%, P = .34, respectively). Some terminally ill patients with cancer in a palliative care unit might benefit from nutritional support.

  2. Experimental study on airflow fluctuation characteristic of an underfloor air supply terminal unit

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Jinping [School of Electric Power, South China University of Technology, Guangzhou 510640 (China); State Key Laboratory of Subtropical Building Science, South China University of Technology, Guangzhou 510640 (China); Wu, Yanfang [Design Institute of Guangzhou Metro Corporation, Guangzhou 510010 (China)

    2010-11-15

    In order to investigate dynamic characteristic of underfloor air supply terminal unit, an IFV900A hot-wire anemometer was used to measure the corresponding velocity field. Turbulence intensity and power spectrum density exponent of air velocity signal were analyzed. The result showed that the outlet velocity distribution of underfloor air supply terminal unit was uniform. With increment of height, the velocity distribution trends to be uniform. Two velocity attenuation regions appear during airflow development. Turbulence intensity changes obviously with height. It is lower than that of mechanical wind. Turbulence intensity goes up with the increment of jetting distance. Power spectrum density exponent trends to the value of natural wind with increase of jetting distance and decrease of wind velocity. The exponent value approaches to the value of typical natural wind for the air velocity is 0.5 m/s under high supply air rate. With airflow diffusion, the fluctuation characteristic of airflow varies obviously with the jetting direction. The fluctuation characteristic of airflow changes to that of natural wind with the increase of height which can improve comfort of indoor environment. (author)

  3. Pipelines, utilities plan over 150 scada systems

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    This paper reports that North American pipelines and utilities will spend more than $170 million on new or upgraded supervisory control and data acquisition (scada) systems during the 30-month period that commenced Sept. 1. Another $12.5 million will be spent on peripherals and consulting. Among the 699 various projects to be implemented during the period, companies will install 151 scada systems, add 154 remote-terminal units (RTUs) to existing scada units, and install 196 communications systems. Scada systems are computerized hardware and software systems that perform a set of monitoring and control functions. In gas utilities, these systems perform functions normally associated with gas transmission and distribution as well as production plant process control. In gas and oil pipelines, the systems perform these functions as well as such specialized functions as batch tracking, leak detection, and gas load flow

  4. Kitimat LNG terminal

    International Nuclear Information System (INIS)

    Schmaltz, I.; Boulton, R.

    2007-01-01

    Kitimat Liquefied Natural Gas (LNG) terminal is a terminal development company owned by Galveston LNG, a privately owned Canadian energy development company. This presentation provided information on Kitimat LNG with particular reference to its terminal located in Bish Cove on the Douglas Channel in British Columbia. This LNG terminal is reported to be the only fully permitted regasification terminal on the west coast of Canada and the United States. The presentation addressed market fundamentals including several graphs, such as world natural gas proved reserves in 2006; LNG supplements to Canadian gas supplies; global LNG demand for 2005-2020; average annual United States LNG imports; and global LNG liquefaction projects. Other market fundamentals were described, including that Kitimat is the only other approved terminal aside from the Costa Azul terminal in Mexico; Kitimat is the only west coast LNG import terminal that connects to midwest and eastern North American markets through existing gas pipelines; LNG producers are looking for destination diversification; and markets and marketers are looking for supply diversification. The authors noted that by 2010, western Canadian gas demand will exceed Californian demand. Other topics that were discussed in the presentation included Canadian natural gas field receipts; unadjusted bitumen production outlook; oil sands gas demand; forward basis fundamentals; and the commercial drivers of the Kitimat LNG terminal. The presentation also discussed the pacific trail pipelines, a partnership between Galveston LNG and Pacific Northern Gas to develop the natural gas transmission line from Kitimat to Summit. The presentation concluded with a discussion of the benefits of Kitimat LNG terminal such as providing access to the largest natural gas markets in the world via major gas transmission lines with spare capacity. figs

  5. Key management issue in SCADA networks: A review

    Directory of Open Access Journals (Sweden)

    Abdalhossein Rezai

    2017-02-01

    Full Text Available Supervisory Control And Data Acquisition (SCADA networks have a vital role in Critical Infrastructures (CIs such as public transports, power generation systems, gas, water and oil industries, so that there are concerns on security issues in these networks. The utilized Remote Terminal Units (RTUs and Intelligence Electronic Devices (IEDs in these networks have resource limitations, which make security applications a challenging issue. Efficient key management schemes are required besides lightweight ciphers for securing the SCADA communications. Many key management schemes have been developed to address the tradeoff between SCADA constrain and security, but which scheme is the most effective is still debatable. This paper presents a review of the existing key management schemes in SCADA networks, which provides directions for further researches in this field.

  6. Terminating America's wars : the Gulf War and Kosovo

    OpenAIRE

    Musser, William G.

    2002-01-01

    Approved for public release; distribution is unlimited This thesis asks two questions: 1) What factors have contributed to the termination of recent United States wars? and 2) How can elements of national power be applied successfully to terminate the future wars of the United States? To answer these questions, this thesis offers a model of war termination and applies it to cases of war termination, in the Gulf War and in Kosovo. These case studies indicate that termination of future wars ...

  7. Dying in Palliative Care Units and in Hospital: A Comparison of the Quality of Life of Terminal Cancer Patients.

    Science.gov (United States)

    Viney, Linda L.; And Others

    1994-01-01

    Compared quality of life of terminal cancer patients (n=182) in two palliative care units with that of those in general hospital. Patients in specialized palliative care units were found to differ from those dying in hospital, showing less indirectly expressed anger but more positive feelings. They also reported more anxiety about death but less…

  8. 46 CFR 525.2 - Terminal schedules.

    Science.gov (United States)

    2010-10-01

    ... domestic law and international conventions and agreements adopted by the United States; such terminal... their own negligence, or that impose upon others the obligation to indemnify or hold-harmless the terminals from liability for their own negligence. (2) Enforcement of terminal schedules. Any schedule that...

  9. Evaluation model for enterprise standardization programs: the case of Petrobras Transporte's marine terminals unit

    Energy Technology Data Exchange (ETDEWEB)

    Maldonado, Luciano; De Ludovico Almeida, Maria Fatima; Penchino Pereira, Paulo Penchina; Santos, Ubirajara; Henrique Ferreira, Manoel; Muller, Gabriela [Petrobras Transporte - Transpetro (Brazil)

    2010-07-01

    With the economic opening and the globalization process, standardization, metrology and quality activities have become known among companies as knowledge areas with direct impact on their search for operational excellence and competitiveness. Petrobras Transporte's Marine Terminal Units has been working over the last years to be recognized as a reference in the activities it pursues. This is based on the Petrobras Transporte's strategic plan 2020, which foresees amongst others, the specialization of technical workforce, operational safety excellence, capital discipline, customer satisfaction, the search for new technologies and markets and the rendering of new services. To achieve these goals, the Marine Terminals Standardization Program must be adhered to. Since that program was launched in 2004, the need for an evaluation model to evaluate its implementation progress, measure the degree of standards compliance and its potential economic, social and environmental impacts have become evident. This paper describes the innovative evaluation model applied to Petrobras Transporte's marine terminals standardization program.

  10. Tandem Terminal Ion Source

    International Nuclear Information System (INIS)

    Harper, G.C.; Lindner, C.E.; Myers, A.W.; Wechel, T.D. van

    2000-01-01

    OAK-B135 Tandem Terminal Ion Source. The terminal ion source (TIS) was used in several experiments during this reporting period, all for the 7 Be(γ) 8 B experiment. Most of the runs used 1 H + at terminal voltages from 0.3 MV to 1.5 MV. One of the runs used 2 H + at terminal voltage of 1.4 MV. The other run used 4 He + at a terminal voltage of 1.37 MV. The list of experiments run with the TIS to date is given in table 1 below. The tank was opened four times for unscheduled source repairs. On one occasion the tank was opened to replace the einzel lens power supply which had failed. The 10 kV unit was replaced with a 15 kV unit. The second time the tank was opened to repair the extractor supply which was damaged by a tank spark. On the next occasion the tank was opened to replace a source canal which had sputtered away. Finally, the tank was opened to replace the discharge bottle which had been coated with aluminum sputtered from the exit canal

  11. Tandem Terminal Ion Source

    International Nuclear Information System (INIS)

    None

    2000-01-01

    OAK-B135 Tandem Terminal Ion Source. The terminal ion source (TIS) was used in several experiments during this reporting period, all for the(sup 7)Be((gamma))(sup 8)B experiment. Most of the runs used(sup 1)H(sup+) at terminal voltages from 0.3 MV to 1.5 MV. One of the runs used(sup 2)H(sup+) at terminal voltage of 1.4 MV. The other run used(sup 4)He(sup+) at a terminal voltage of 1.37 MV. The list of experiments run with the TIS to date is given in table 1 below. The tank was opened four times for unscheduled source repairs. On one occasion the tank was opened to replace the einzel lens power supply which had failed. The 10 kV unit was replaced with a 15 kV unit. The second time the tank was opened to repair the extractor supply which was damaged by a tank spark. On the next occasion the tank was opened to replace a source canal which had sputtered away. Finally, the tank was opened to replace the discharge bottle which had been coated with aluminum sputtered from the exit canal

  12. Pipeline, utilities to spend $127 million on scada systems

    International Nuclear Information System (INIS)

    Anon.

    1993-01-01

    Spending for new or upgraded supervisory control and data acquisition (scada) systems and for additional remote-terminal units (RTUs) by North American pipelines and utilities will exceed $165 million through February 1996. New and updated scada systems will total 122 at a cost of more than $127 million; 143 RTU add-on projects will cost more than $38 million. Pipelines and combined utilities/pipelines will spend $89.5 million for 58 scada-system projects and $30.2 million for RTU add-on projects. Scada systems are computerized hardware and software systems that perform monitoring and control functions. In gas utilities, these systems perform functions normally associated with gas transmission and distribution as well as production-plant process control. In gas and oil pipelines, the systems perform these functions as well as such specialized functions as batch tracking, leak detection, and gas load flow

  13. A Review of Communications Protocol for Intelligent Remote Terminal Unit Development

    Directory of Open Access Journals (Sweden)

    Mohd Ruddin Ab. Ghani

    2013-11-01

    Full Text Available This paper reviewed all the possible interfacing communication protocols for remote terminal unit (RTU. Supervisory Control and Data Acquisition (SCADA system is a central station that can communicate with other network using the protocol. Fundamentally, the architectures of all networks are based on the seven layers of open system interconnection (OSI and International Standard Organization (ISO. The objective of designing the protocols is to check the status of all the input and output field devices and send the report according to that status. The corresponding protocol and communication parameters between the connecting devices will be included in designing a complex SCADA system. The available protocols to develop the communication of RTU are Modbus/ASCII, distributed network protocol (DNP3, controller area network (CAN, International Electro-technical Commission (IEC 60870, transmission control protocol/internet protocol (TCP/IP.

  14. The Text of a Protocol between the Agency and the Governments of Thailand and the United States of America Terminating the Agreement between the International Atomic Energy Agency, the Government of the Kingdom of Thailand and the Government of the United States of America for the Application of Safeguards and Terminating the Protocol Suspending that Agreement

    International Nuclear Information System (INIS)

    1976-01-01

    The text of a protocol between the Agency and the Governments of Thailand and the United States of America terminating the Agreement between the International Atomic Energy Agency, the Government of the Kingdom of Thailand and the Government of the United States of America for the Application of Safeguards and terminating the Protocol suspending that Agreement is reproduced in this document for the information of all Members. The Protocol entered into force on 27 June 1974, pursuant to Section 6 thereof.

  15. Standardization process aligned to integrated management system: the case of TRANSPETRO's Oil Pipelines and Terminals Unit

    Energy Technology Data Exchange (ETDEWEB)

    Almeida, Maria Fatima Ludovico de [Pontificia Universidade Catolica do Rio de Janeiro (PUC-Rio/ITUC), Rio de Janeiro, RJ (Brazil). Instituto Tecnologico; Labrunie, Charles; Araujo, Dario Doria de [TRANSPETRO - PETROBRAS Transporte S.A., Rio de Janeiro, RJ (Brazil). Diretoria de Terminais e Oleodutos

    2009-07-01

    This paper presents the implementation by PETROBRAS Transporte S.A. - TRANSPETRO of its Oil Pipelines and Terminals Standardization Program (PRONOT) within the scope of the 'Integrated Management System' (IMS). This program, launched in 2006 in the regions where the company operates, aims at standardizing all of its oil pipeline and terminal operations. Its implementation was planned in two phases: the first, already successfully concluded, refers to pipeline operations, industrial maintenance and right-of-way activities management; and the second, initiated in 2009, encompasses cross-sectional activities including health, safety and environment (HSE); training and development of oil pipeline workforce; communication with stake holders; oil pipeline integrity; and engineering project requirements. The documental structures of TRANSPETRO IMS and PRONOT are described and represented graphically to emphasize the intentional alignment of the standardization process carried out by the Oil Pipelines and Terminals Unit to the corporate IMS, based upon national and international literature review and through practical research focusing on the best international practices. (author)

  16. Development and Evaluation of Algorithms to Improve Small- and Medium-Size Commercial Building Operations

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Woohyun [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Katipamula, Srinivas [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Lutes, Robert G. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Underhill, Ronald M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-10-31

    Small- and medium-sized (<100,000 sf) commercial buildings (SMBs) represent over 95% of the U.S. commercial building stock and consume over 60% of total site energy consumption. Many of these buildings use rudimentary controls that are mostly manual, with limited scheduling capability, no monitoring or failure management. Therefore, many of these buildings are operated inefficiently and consume excess energy. SMBs typically utilize packaged rooftop units (RTUs) that are controlled by an individual thermostat. There is increased urgency to improve the operating efficiency of existing commercial building stock in the U.S. for many reasons, chief among them is to mitigate the climate change impacts. Studies have shown that managing set points and schedules of the RTUs will result in up to 20% energy and cost savings. Another problem associated with RTUs is short-cycling, where an RTU goes through ON and OFF cycles too frequently. Excessive cycling can lead to excessive wear and lead to premature failure of the compressor or its components. The short cycling can result in a significantly decreased average efficiency (up to 10%), even if there are no physical failures in the equipment. Also, SMBs use a time-of-day scheduling is to start the RTUs before the building will be occupied and shut it off when unoccupied. Ensuring correct use of the zone set points and eliminating frequent cycling of RTUs thereby leading to persistent building operations can significantly increase the operational efficiency of the SMBs. A growing trend is to use low-cost control infrastructure that can enable scalable and cost-effective intelligent building operations. The work reported in this report describes three algorithms for detecting the zone set point temperature, RTU cycling rate and occupancy schedule detection that can be deployed on the low-cost infrastructure. These algorithms only require the zone temperature data for detection. The algorithms have been tested and validated using

  17. Attitudes Towards Prenatal Genetic Counseling, Prenatal Genetic Testing, and Termination of Pregnancy among Southeast and East Asian Women in the United States.

    Science.gov (United States)

    Tsai, Ginger J; Cameron, Carrie A; Czerwinski, Jennifer L; Mendez-Figueroa, Hector; Peterson, Susan K; Noblin, Sarah Jane

    2017-10-01

    Recognizing the heterogeneity of the Asian population with regards to acculturation, education, health awareness, and cultural values is vital for tailoring culturally sensitive and appropriate care. Prior studies show that cultural values influence perceptions of genetics within Asian populations. The reputation of the family unit factors into decisions such as pregnancy termination and disclosure of family medical history, and the nondirective model of American genetic counseling may conflict with the historical Asian model of paternalistic health care. Previous studies also provide conflicting evidence regarding correlations between education, acculturation, age, and awareness and perceptions of genetic testing. The aims of this study were to describe attitudes towards prenatal genetics among Southeast and East Asian women living in the United States for varying amounts of time and to explore sociocultural factors influencing those attitudes. Twenty-three Asian women who were members of Asian cultural organizations in the United States were interviewed via telephone about their attitudes towards prenatal genetic counseling, prenatal genetic testing, and termination of pregnancy. Responses were transcribed and coded for common themes using a thematic analysis approach. Four major themes emerged. In general, participants: (1) had diverse expectations for genetic counselors; (2) tended to weigh risks and benefits with regards to genetic testing decisions; (3) had mixed views on termination for lethal and non-lethal genetic conditions; and (4) identified cultural factors which influenced testing and termination such as lack of available resources, societal shame and stigma, and family pressure. These findings may allow prenatal genetic counselors to gain a richer, more nuanced understanding of their Asian patients and to offer culturally tailored prenatal genetic counseling.

  18. Dictionary of nuclear energy termination

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1983-04-15

    This book lists termination of nuclear energy such as abbreviation, symbol, unit of nuclear energy, radiological unit, the symbol for element, isotope chart and the periodic table. This book contains about 5500 words involving to nuclear energy with index in Korean and English. It arranges alphabetically. So, with this book, it is easy and fast to find out the glossary, unit and symbol on nuclear energy.

  19. Dictionary of nuclear energy termination

    International Nuclear Information System (INIS)

    1983-04-01

    This book lists termination of nuclear energy such as abbreviation, symbol, unit of nuclear energy, radiological unit, the symbol for element, isotope chart and the periodic table. This book contains about 5500 words involving to nuclear energy with index in Korean and English. It arranges alphabetically. So, with this book, it is easy and fast to find out the glossary, unit and symbol on nuclear energy.

  20. 19 CFR 210.41 - Termination of investigation.

    Science.gov (United States)

    2010-04-01

    ... 19 Customs Duties 3 2010-04-01 2010-04-01 false Termination of investigation. 210.41 Section 210.41 Customs Duties UNITED STATES INTERNATIONAL TRADE COMMISSION INVESTIGATIONS OF UNFAIR PRACTICES IN IMPORT TRADE ADJUDICATION AND ENFORCEMENT Determinations and Actions Taken § 210.41 Termination of...

  1. Inter-terminal transfer between port terminals. A continuous mathematical programming model to optimize scheduling and deployment of transport units

    Energy Technology Data Exchange (ETDEWEB)

    Morales Fusco, P.; Pedrielli, G.; Zhou, C.; Hay Lee, L.; Peng Chew, E.

    2016-07-01

    In most large port cities, the challenge of inter-terminal transfers (ITT) prevails due to the long distance between multiple terminals. The quantity of containers requiring movement between terminals as they connect from pre-carrier to on-carrier is increasing with the formation of the mega-alliances. The paper proposes a continuous time mathematical programming model to optimize the deployment and schedule of trucks and barges to minimize the number of operating transporters, their makespan, costs and the distance travelled by the containers by choosing the right combination of transporters and container movements while fulfilling time window restrictions imposed on reception of the containers. A multi-step routing problem is developed where transporters can travel from one terminal to another and/or load or unload containers from a specific batch at each step. The model proves successful in identifying the costless schedule and means of transportation. And a sensibility analysis over the parameters used is provided. (Author)

  2. Prototype data terminal: Multiplexer/demultiplexer

    Science.gov (United States)

    Leck, D. E.; Goodwin, J. E.

    1972-01-01

    The design and operation of a quad redundant data terminal and a multiplexer/demultiplexer (MDU) design are described. The most unique feature is the design of the quad redundant data terminal. This is one of the few designs where the unit is fail/op, fail/op, fail/safe. Laboratory tests confirm that the unit will operate satisfactorily with the failure of three out of four channels. Although the design utilizes state-of-the-art technology. The waveform error checks, the voting techniques, and the parity bit checks are believed to be used in unique configurations. Correct word selection routines are also novel, if not unique. The MDU design, while not redundant, utilizes, the latest state-of-the-art advantages of light couplers and integrated circuit amplifiers.

  3. Performance Evaluation and Modelling of Container Terminals

    Science.gov (United States)

    Venkatasubbaiah, K.; Rao, K. Narayana; Rao, M. Malleswara; Challa, Suresh

    2018-02-01

    The present paper evaluates and analyzes the performance of 28 container terminals of south East Asia through data envelopment analysis (DEA), principal component analysis (PCA) and hybrid method of DEA-PCA. DEA technique is utilized to identify efficient decision making unit (DMU)s and to rank DMUs in a peer appraisal mode. PCA is a multivariate statistical method to evaluate the performance of container terminals. In hybrid method, DEA is integrated with PCA to arrive the ranking of container terminals. Based on the composite ranking, performance modelling and optimization of container terminals is carried out through response surface methodology (RSM).

  4. Quantifying morphological parameters of the terminal branching units in a mouse lung by phase contrast synchrotron radiation computed tomography.

    Directory of Open Access Journals (Sweden)

    Jeongeun Hwang

    Full Text Available An effective technique of phase contrast synchrotron radiation computed tomography was established for the quantitative analysis of the microstructures in the respiratory zone of a mouse lung. Heitzman's method was adopted for the whole-lung sample preparation, and Canny's edge detector was used for locating the air-tissue boundaries. This technique revealed detailed morphology of the respiratory zone components, including terminal bronchioles and alveolar sacs, with sufficiently high resolution of 1.74 µm isotropic voxel size. The technique enabled visual inspection of the respiratory zone components and comprehension of their relative positions in three dimensions. To check the method's feasibility for quantitative imaging, morphological parameters such as diameter, surface area and volume were measured and analyzed for sixteen randomly selected terminal branching units, each consisting of a terminal bronchiole and a pair of succeeding alveolar sacs. The four types of asymmetry ratios concerning alveolar sac mouth diameter, alveolar sac surface area, and alveolar sac volume are measured. This is the first ever finding of the asymmetry ratio for the terminal bronchioles and alveolar sacs, and it is noteworthy that an appreciable degree of branching asymmetry was observed among the alveolar sacs at the terminal end of the airway tree, despite the number of samples was small yet. The series of efficient techniques developed and confirmed in this study, from sample preparation to quantification, is expected to contribute to a wider and exacter application of phase contrast synchrotron radiation computed tomography to a variety of studies.

  5. Estimation of the influence of the early termination of the operation of units 1- 4 in NPP Kozloduy on the greenhouse gas emissions and the obligations of Republic of Bulgaria regarding the Kyoto Protocol

    International Nuclear Information System (INIS)

    Christov, Chr.; Vasilev, Hr.

    2003-01-01

    The case of early termination of the operation of units 1 - 4 in NPP 'Kozloduy' would have a considerable impact on the greenhouse gas (GHG) emissions because in the structure of the electricity production the nuclear power plant occupies over 40%. Due to decrease of the share of the nuclear energy in the electricity production the share of the solid and gaseous fuels increases. They are a considerable source of GHG. Three scenarios for the development of the electric power sector until year 2015 have been studied for the case of early termination of the operation of units 1 - 4 in NPP: Scenario 1: Early termination of the operation of units 1 - 4 according to terms pointed out by the EU. Scenario 2: Decommissioning of units 1 - 4 according to term in the project design. Scenario 3: Early termination of the operation of units 1 - 2 according to terms pointed out by the EU and decommissioning of units 3 - 4 according to terms in the project design. Comparative calculations have been performed for the forecasted GHG emission quantities in the first commitment period of the Kyoto Protocol (2008 - 2012). The potential for possible quantities of GHG emissions that could be traded during the entire five-year period are estimated. At minimum possible price of the emissions 5 $US/tCO 2 the annual income will be at least 100 - 130 mill $US. The realistic estimation regarding the omitted benefits due to early termination of the operation of units 1 - 4 is about 900 mill $US for the five year period of Kyoto. The continued operation of units 3 - 4 to the end of the term defined in the project design could make it possible to fulfill an income of 700 mill to 1 billion $US from emission trading

  6. Digital autonomous terminal access communications

    Science.gov (United States)

    Novacki, S.

    1987-01-01

    A significant problem for the Bus Monitor Unit is to identify the source of a given transmission. This problem arises from the fact that the label which identifies the source of the transmission as it is put into the bus is intercepted by the Digital Autonomous Terminal Access Communications (DATAC) terminal and removed from the transmission. Thus, a given subsystem will see only data associated with a label and never the identifying label itself. The Bus Monitor must identify the source of the transmission so as to be able to provide some type of error identification/location in the event that some problem with the data transmission occurs. Steps taken to alleviate this problem by modifications to the DATAC terminal are discussed.

  7. Concept Layout Model of Transportation Terminals

    Directory of Open Access Journals (Sweden)

    Li-ya Yao

    2012-01-01

    Full Text Available Transportation terminal is the key node in transport systems. Efficient terminals can improve operation of passenger transportation networks, adjust the layout of public transportation networks, provide a passenger guidance system, and regulate the development of commercial forms, as well as optimize the assembly and distribution of modern logistic modes, among others. This study aims to clarify the relationship between the function and the structure of transportation terminals and establish the function layout design. The mapping mechanism of demand, function, and structure was analyzed, and a quantitative relationship between function and structure was obtained from a design perspective. Passenger demand and terminal structure were decomposed into several demand units and structural elements following the principle of reverse engineering. The relationship maps between these two kinds of elements were then analyzed. Function-oriented concept layout model of transportation terminals was established using the previous method. Thus, a technique in planning and design of transportation structures was proposed. Meaningful results were obtained from the optimization of transportation terminal facilities, which guide the design of the functional layout of transportation terminals and improve the development of urban passenger transportation systems.

  8. Transactional Network Platform: Applications

    Energy Technology Data Exchange (ETDEWEB)

    Katipamula, Srinivas; Lutes, Robert G.; Ngo, Hung; Underhill, Ronald M.

    2013-10-31

    In FY13, Pacific Northwest National Laboratory (PNNL) with funding from the Department of Energy’s (DOE’s) Building Technologies Office (BTO) designed, prototyped and tested a transactional network platform to support energy, operational and financial transactions between any networked entities (equipment, organizations, buildings, grid, etc.). Initially, in FY13, the concept demonstrated transactions between packaged rooftop air conditioners and heat pump units (RTUs) and the electric grid using applications or "agents" that reside on the platform, on the equipment, on a local building controller or in the Cloud. The transactional network project is a multi-lab effort with Oakridge National Laboratory (ORNL) and Lawrence Berkeley National Laboratory (LBNL) also contributing to the effort. PNNL coordinated the project and also was responsible for the development of the transactional network (TN) platform and three different applications associated with RTUs. This document describes two applications or "agents" in details, and also summarizes the platform. The TN platform details are described in another companion document.

  9. PFD user exit routine for graphic terminal D-SCAN

    International Nuclear Information System (INIS)

    Aoyagi, Tetsuo; Ninomiya, Hiromasa; Tani, Keiji

    1985-01-01

    Screen editor under the TSS system became primary way to edit text data sets which include programs and/or data records. The screen editor has come to be available on some TTY terminals with video display unit besides particular terminals. The command conversion program was developed in order to use the screen editor on other TTY terminals with different command set (D-SCAN). The design of the program is illustrated in this report. (author)

  10. Development of the multiwavelength monolithic integrated fiber optics terminal

    Science.gov (United States)

    Chubb, C. R.; Bryan, D. A.; Powers, J. K.; Rice, R. R.; Nettle, V. H.; Dalke, E. A.; Reed, W. R.

    1982-01-01

    This paper describes the development of the Multiwavelength Monolithic Integrated Fiber Optic Terminal (MMIFOT) for the NASA Johnson Space Center. The program objective is to utilize guided wave optical technology to develop wavelength-multiplexing and -demultiplexing units, using a single mode optical fiber for transmission between terminals. Intensity modulated injection laser diodes, chirped diffraction gratings and thin film lenses are used to achieve the wavelength-multiplexing and -demultiplexing. The video and audio data transmission test of an integrated optical unit with a Luneburg collimation lens, waveguide diffraction grating and step index condensing lens is described.

  11. Cable Terminations for the BSURE (Barking Sands Underwater Range Expansion) Terminal and Transmission Units (TATU). Design Review Team Report.

    Science.gov (United States)

    1985-01-01

    One, a cable termination pull out and two, leakage. It is felt that both of these problems have been solved. The cable termiration pullout problem...nm selctroicse~I -. V~- 30.3 Z? Ul.T Casio Ca" inOS Allow waer to tam. feai Mone 11 l i"f MM Goali (30.321) -= 9to75 % col roo NMI V023 ’..ca...t-he third typ. of failure, an SD cable pulled out of termination. This was obviously not caused by a Morrison seal or an 0-ring. it appears

  12. Power system data communication architecture at BC Hydro

    Energy Technology Data Exchange (ETDEWEB)

    Struyk, E.

    2001-07-01

    Development of a power system data communication architecture (PSDCA) at British Columbia Hydro that enables authorized corporate users to access station-intelligent electronic devices (IEDs) for power system data in non real-time, without compromising the reliability and availability of the real-time SCADA systems, is described. Also discussed is the development of major upgrade initiatives for expanding the use of intelligent electronic devices and remote terminal units (RTUs) which report to the main System Control Centre at Burnaby, BC, and to the four Area Control Centres located throughout the province. The network architecture that incorporates industry standards for PSDCA also provides an opportunity to existing network security systems against electronic threats such as hackers and saboteurs, beyond the simple methods of single or two-level passwords of existing protection control and monitoring equipment systems. The virtual private network (VPN) technology built into the PSDCA will allow secure access to station IED data by corporate users to access their own power data in a secure and reliable fashion. 4 figs.

  13. Capacity Analysis of Ro-Ro Terminals by Using Simulation Modeling Method

    Directory of Open Access Journals (Sweden)

    Emin Deniz Özkan

    2016-09-01

    Full Text Available In Ro-Ro terminals, terminal capacity is more needed than other types of marine terminals since Ro-Ro cargoes cannot be stacked. In this sense, the variables affecting capacity of a Ro-Ro terminal can be listed as follows; number of vehicles arrived to a terminal, distance between terminals, ship capacity, terminal gates, customs control units, terminal traffic and local traffic, security check, bunkering services etc. In this study, a model generated intended for making capacity analysis in Ro-Ro terminals by using simulation modeling method. Effect of three variables to terminal capacity was investigated while generating the scenarios; ‘number of trucks arriving to terminals’, ‘distance between terminals’ and ‘Ro-Ro ship capacity’. The results show that the variable which affect terminal capacity mostly is ‘number of trucks arriving to terminals’. As a consequence of this situation, it is thought that a Ro-Ro terminal operator must prioritize the demand factor and make an effective demand forecasting in determination of the terminal area.

  14. Formation of a silicon terminated (100) diamond surface

    International Nuclear Information System (INIS)

    Schenk, Alex; Sear, Michael; Pakes, Chris; Tadich, Anton; O'Donnell, Kane M.; Ley, Lothar; Stacey, Alastair

    2015-01-01

    We report the preparation of an ordered silicon terminated diamond (100) surface with a two domain 3 × 1 reconstruction as determined by low energy electron diffraction. Based on the dimensions of the surface unit cell and on chemical information provided by core level photoemission spectra, a model for the structure is proposed. The termination should provide a homogeneous, nuclear, and electron spin-free surface for the development of future near-surface diamond quantum device architectures

  15. A hanging drop culture method to study terminal erythroid differentiation.

    Science.gov (United States)

    Gutiérrez, Laura; Lindeboom, Fokke; Ferreira, Rita; Drissen, Roy; Grosveld, Frank; Whyatt, David; Philipsen, Sjaak

    2005-10-01

    To design a culture method allowing the quantitative and qualitative analysis of terminal erythroid differentiation. Primary erythroid progenitors derived either from mouse tissues or from human umbilical cord blood were differentiated using hanging drop cultures and compared to methylcellulose cultures. Cultured cells were analyzed by FACS to assess differentiation. We describe a practical culture method by adapting the previously described hanging drop culture system to conditions allowing terminal differentiation of primary erythroid progenitors. Using minimal volumes of media and small numbers of cells, we obtained quantitative terminal erythroid differentiation within two days of culture in the case of murine cells and 4 days in the case of human cells. The established methods for ex vivo culture of primary erythroid progenitors, such as methylcellulose-based burst-forming unit-erythroid (BFU-E) and colony-forming unit-erythroid (CFU-E) assays, allow the detection of committed erythroid progenitors but are of limited value to study terminal erythroid differentiation. We show that the application of hanging drop cultures is a practical alternative that, in combination with clonogenic assays, enables a comprehensive assessment of the behavior of primary erythroid cells ex vivo in the context of genetic and drug-induced perturbations.

  16. Prototype data terminal-multiplexer/demultiplexer

    Science.gov (United States)

    Leck, D. E.; Goodwin, J. E.

    1972-01-01

    The design and operation of a quad redundant data terminal and a multiplexer/demultiplexer (MDU) is described. The most unique feature is the design of the quad redundant data terminal. This is one of the few designs where the unit is fail/op, fail/op, fail/safe. Laboratory tests confirm that the unit will operate satisfactorily with the failure of three out of four channels. Although the design utilizes state-of-the-art technology, the waveform error checks, the voting techniques, and the parity bit checks are believed to be used in unique configurations. Correct word selection routines are also novel. The MDU design, while not redundant, utilizes, the latest state-of-the-art advantages of light coupler and interested amplifiers. Much of the technology employed was an evolution of prior NASA contracts related to the Addressable Time Division Data System. A good example of the earlier technology development was the development of a low level analog multiplexer, a high level analog multiplexer, and a digital multiplexer. A list of all drawings is included for reference and all schematic, block and timing diagrams are incorporated.

  17. 19 CFR 210.21 - Termination of investigations.

    Science.gov (United States)

    2010-04-01

    ....21 Customs Duties UNITED STATES INTERNATIONAL TRADE COMMISSION INVESTIGATIONS OF UNFAIR PRACTICES IN IMPORT TRADE ADJUDICATION AND ENFORCEMENT Motions § 210.21 Termination of investigations. (a) Motions for... and Human Services, the U.S. Department of Justice, the Federal Trade Commission, the U.S. Customs...

  18. Modular approach for satellite communication ground terminals

    Science.gov (United States)

    Gould, G. R.

    1984-01-01

    The trend in satellite communications is toward completely digital, time division multiple access (TDMA) systems with uplink and downlink data rates dictated by the type of service offered. Trunking terminals will operate in the 550 MBPS (megabit per second) region uplink and downlink, whereas customer premise service (CPS) terminals will operate in the 25 to 10 MBPS region uplink and in the 200 MBPS region downlink. Additional criteria for the ground terminals will be to maintain clock sychronization with the system and burst time integrity to within a matter of nanoseconds, to process required order-fire information, to provide adaptive data scrambing, and to compensate for variations in the user input output data rates, and for changes in range in the satellite communications links resulting from satellite perturbations in orbit. To achieve the required adaptability of a ground terminal to the above mentioned variables, programmable building blocks can be developed that will meet all of these requirements. To maintain system synchronization, i.e., all bursted data arriving at the satellite within assigned TDMA windows, ground terminal transmit data rates and burst timing must be maintained within tight tolerances. With a programmable synchronizer as the heart of the terminal timing generation, variable data rates and burst timing tolerances are achievable. In essence, the unit inputs microprocessor generated timing words and outputs discrete timing pulses.

  19. Optimal Cotton Insecticide Application Termination Timing: A Meta-Analysis.

    Science.gov (United States)

    Griffin, T W; Zapata, S D

    2016-08-01

    The concept of insecticide termination timing is generally accepted among cotton (Gossypium hirsutum) researchers; however, exact timings are often disputed. Specifically, there is uncertainty regarding the last economic insecticide application to control fruit-feeding pests including tarnished plant bug (Lygus lineolaris (Palisot de Beauvois)), boll weevil (Anthonomus grandis), bollworm (Helicoverpa zea), tobacco budworm (Heliothis virescens), and cotton fleahopper (Pseudatomoscelis seriatus). A systematic review of prior studies was conducted within a meta-analytic framework. Nine publicly available articles were amalgamated to develop an optimal timing principle. These prior studies reported 53 independent multiple means comparison field experiments for a total of 247 trial observations. Stochastic plateau theory integrated with econometric meta-analysis methodology was applied to the meta-database to determine the shape of the functional form of both the agronomic optimal insecticide termination timing and corresponding yield potential. Results indicated that current university insecticide termination timing recommendations are later than overall estimated timing suggested. The estimated 159 heat units (HU) after the fifth position above white flower (NAWF5) was found to be statistically different than the 194 HU termination used as the status quo recommended termination timing. Insecticides applied after 159 HU may have been applied in excess, resulting in unnecessary economic and environmental costs. Empirical results also suggested that extending the insecticide termination time by one unit resulted in a cotton lint yield increase of 0.27 kilograms per hectare up to the timing where the plateau began. Based on economic analyses, profit-maximizing producers may cease application as soon as 124 HU after NAWF5. These results provided insights useful to improve production systems by applying inputs only when benefits were expected to be in excess of the

  20. Standardization process for pipeline right-of-way activities: the case of TRANSPETRO's Oil Pipeline and Terminals Business Unit

    Energy Technology Data Exchange (ETDEWEB)

    Ribeiro, Kassandra Senra de Morais M.; Goncalves, Bruno Martins [TRANSPETRO - PETROBRAS Transporte S.A., Rio de Janeiro, RJ (Brazil). Diretoria de Terminais e Oleodutos; Almeida, Maria Fatima Ludovico de [Pontificia Universidade Catolica do Rio de Janeiro (PUC-Rio/ITUC), Rio de Janeiro, RJ (Brazil). Instituto Tecnologico

    2009-07-01

    This paper describes the experience of PETROBRAS Transporte S.A. concerning the standardization process for its pipeline right-of-way (ROW) activities. This standardization initiative has been carried out within the Oil Pipelines and Terminals Standardization Program (PRONOT), focusing on planning, standardization and implementation of all norms and corporate procedures referring to TRANSPETRO's right-of-way activities. The process promoted the integration of isolated regional initiatives, a sense of unity and the creation of a learning network consisting of 60 employees. This paper presents the last phase's results concerning implementation of corporate standards, based upon achievements of previous phases. It covers the following topics: a general view of the whole process by way of introduction; the potential of integration of recent standardization results with TRANSPETRO's corporate management tools and information systems; definition of four performance indicators and their metrics related to pipeline right-of-way management, as well as a corporate standard for the requirements for contracting services related to rights-of-way inspection, maintenance and communication; challenges, barriers and benefits perceived by the team responsible for formulating and implementing standards and procedures in TRANSPETRO's Oil Pipelines and Terminals Unit. (author)

  1. Programmable logic controller optical fibre sensor interface module

    Science.gov (United States)

    Allwood, Gary; Wild, Graham; Hinckley, Steven

    2011-12-01

    Most automated industrial processes use Distributed Control Systems (DCSs) or Programmable Logic Controllers (PLCs) for automated control. PLCs tend to be more common as they have much of the functionality of DCSs, although they are generally cheaper to install and maintain. PLCs in conjunction with a human machine interface form the basis of Supervisory Control And Data Acquisition (SCADA) systems, combined with communication infrastructure and Remote Terminal Units (RTUs). RTU's basically convert different sensor measurands in to digital data that is sent back to the PLC or supervisory system. Optical fibre sensors are becoming more common in industrial processes because of their many advantageous properties. Being small, lightweight, highly sensitive, and immune to electromagnetic interference, means they are an ideal solution for a variety of diverse sensing applications. Here, we have developed a PLC Optical Fibre Sensor Interface Module (OFSIM), in which an optical fibre is connected directly to the OFSIM located next to the PLC. The embedded fibre Bragg grating sensors, are highly sensitive and can detect a number of different measurands such as temperature, pressure and strain without the need for a power supply.

  2. NPOESS Field Terminal Updates

    Science.gov (United States)

    Heckmann, G.; Route, G.

    2009-12-01

    The National Oceanic and Atmospheric Administration (NOAA), Department of Defense (DoD), and National Aeronautics and Space Administration (NASA) are jointly acquiring the next-generation weather and environmental satellite system; the National Polar-orbiting Operational Environmental Satellite System (NPOESS). NPOESS replaces the current Polar-orbiting Operational Environmental Satellites (POES) managed by NOAA and the Defense Meteorological Satellite Program (DMSP) managed by the DoD. The NPOESS satellites carry a suite of sensors that collect meteorological, oceanographic, climatological, and solar-geophysical observations of the earth, atmosphere, and space. The ground data processing segment for NPOESS is the Interface Data Processing Segment (IDPS), developed by Raytheon Intelligence and Information Systems. The IDPS processes NPOESS satellite data to provide environmental data products (aka, Environmental Data Records or EDRs) to NOAA and DoD processing centers operated by the United States government. The IDPS will process EDRs beginning with the NPOESS Preparatory Project (NPP) and continuing through the lifetime of the NPOESS system. IDPS also provides the software and requirements for the Field Terminal Segment (FTS). NPOESS provides support to deployed field terminals by providing mission data in the Low Rate and High Rate downlinks (LRD/HRD), mission support data needed to generate EDRs and decryption keys needed to decrypt mission data during Selective data Encryption (SDE). Mission support data consists of globally relevant data, geographically constrained data, and two line element sets. NPOESS provides these mission support data via the Internet accessible Mission Support Data Server and HRD/LRD downlinks. This presentation will illustrate and describe the NPOESS capabilities in support of Field Terminal users. This discussion will include the mission support data available to Field Terminal users, content of the direct broadcast HRD and LRD

  3. 76 FR 71022 - Dicloran; Cancellation Order for Amendment To Terminate Use on Potatoes

    Science.gov (United States)

    2011-11-16

    ... the products identified in Table 1 of Unit II. in a manner inconsistent with any of the provisions for... the registrant listed in Table 2 of Unit II. to voluntarily amend to terminate DCNA use on potatoes... registration number in Table 1 of this unit. Table 1--DCNA Product Registration Amendment To Delete Use EPA...

  4. Discrete event simulation model for external yard choice of import container terminal in a port buffer area

    Science.gov (United States)

    Rusgiyarto, Ferry; Sjafruddin, Ade; Frazila, Russ Bona; Suprayogi

    2017-06-01

    Increasing container traffic and land acquisition problem for terminal expansion leads to usage of external yard in a port buffer area. This condition influenced the terminal performance because a road which connects the terminal and the external yard was also used by non-container traffic. Location choice problem considered to solve this condition, but the previous research has not taken account a stochastic condition of container arrival rate and service time yet. Bi-level programming framework was used to find optimum location configuration. In the lower-level, there was a problem to construct the equation, which correlated the terminal operation and the road due to different time cycle equilibrium. Container moves from the quay to a terminal gate in a daily unit of time, meanwhile, it moves from the terminal gate to the external yard through the road in a minute unit of time. If the equation formulated in hourly unit equilibrium, it cannot catch up the container movement characteristics in the terminal. Meanwhile, if the equation formulated in daily unit equilibrium, it cannot catch up the road traffic movement characteristics in the road. This problem can be addressed using simulation model. Discrete Event Simulation Model was used to simulate import container flow processes in the container terminal and external yard. Optimum location configuration in the upper-level was the combinatorial problem, which was solved by Full Enumeration approach. The objective function of the external yard location model was to minimize user transport cost (or time) and to maximize operator benefit. Numerical experiment was run for the scenario assumption of two container handling ways, three external yards, and thirty-day simulation periods. Jakarta International Container Terminal (JICT) container characteristics data was referred for the simulation. Based on five runs which were 5, 10, 15, 20, and 30 repetitions, operation one of three available external yards (external yard

  5. Costs of terminal patients who receive palliative care or usual care in different hospital wards.

    Science.gov (United States)

    Simoens, Steven; Kutten, Betty; Keirse, Emmanuel; Berghe, Paul Vanden; Beguin, Claire; Desmedt, Marianne; Deveugele, Myriam; Léonard, Christian; Paulus, Dominique; Menten, Johan

    2010-11-01

    In addition to the effectiveness of hospital care models for terminal patients, policy makers and health care payers are concerned about their costs. This study aims to measure the hospital costs of treating terminal patients in Belgium from the health care payer perspective. Also, this study compares the costs of palliative and usual care in different types of hospital wards. A multicenter, retrospective cohort study compared costs of palliative care with usual care in acute hospital wards and with care in palliative care units. The study enrolled terminal patients from a representative sample of hospitals. Health care costs included fixed hospital costs and charges relating to medical fees, pharmacy and other charges. Data sources consisted of hospital accountancy data and invoice data. Six hospitals participated in the study, generating a total of 146 patients. The findings showed that palliative care in a palliative care unit was more expensive than palliative care in an acute ward due to higher staffing levels in palliative care units. Palliative care in an acute ward is cheaper than usual care in an acute ward. This study suggests that palliative care models in acute wards need to be supported because such care models appear to be less expensive than usual care and because such care models are likely to better reflect the needs of terminal patients. This finding emphasizes the importance of the timely recognition of the need for palliative care in terminal patients treated in acute wards.

  6. Shift designs for freight handling personnel at air cargo terminals

    DEFF Research Database (Denmark)

    Rong, Aiying; Grunow, Martin

    2009-01-01

    This paper presents an integrated mixed integer linear programming (MILP) model for determining manpower requirements and related personnel shift designs for the build-up and break-down of the unit load devices (ULDs) at the air cargo terminal to minimize manpower costs. To utilize the manpower...... resources efficiently, we implement a new mechanism for demand leveling. In addition, we consider the qualification hierarchy between build-up and break-down workers. A case study based on the real-life data shows that the model is useful for manpower planning at air cargo terminals and the integrated...

  7. Presence of biofilm containing viable multiresistant organisms despite terminal cleaning on clinical surfaces in an intensive care unit.

    Science.gov (United States)

    Vickery, K; Deva, A; Jacombs, A; Allan, J; Valente, P; Gosbell, I B

    2012-01-01

    Despite recent attention to surface cleaning and hand hygiene programmes, multiresistant organisms (MROs) continue to be isolated from the hospital environment. Biofilms, consisting of bacteria embedded in exopolymeric substances (EPS) are difficult to remove due to their increased resistance to detergents and disinfectants, and periodically release free-swimming planktonic bacteria back into the environment which may may act as an infection source. To establish whether reservoirs of MROs exist in the environment as biofilms. Following terminal cleaning, equipment and furnishings were removed aseptically from an intensive care unit (ICU) and subjected to culture and scanning electron microscopy (SEM). Samples were placed in 5 mL of tryptone soya broth, sonicated for 5 min before plate culture on horse blood agar, Brillance MRSA and Brilliance VRE agar plates. Samples for SEM were fixed in 3% glutaraldehyde and hexamethyldisilizane (HMDS) prior to sputter-coating with gold and examination in an electron microscope. Biofilm was demonstrated visually on the sterile supply bucket, the opaque plastic door, the venetian blind cord, and the sink rubber, whereas EPS alone was seen on the curtain. Viable bacteria were grown from three samples, including MRSA from the venetian blind cord and the curtain. Biofilm containing MROs persist on clinical surfaces from an ICU despite terminal cleaning, suggesting that current cleaning practices are inadequate to control biofilm development. The presence of MROs being protected within these biofilms may be the mechanism by which MROs persist within the hospital environment. Copyright © 2011 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  8. A Study on the Efficiency of Container Terminals in Korea and China

    Directory of Open Access Journals (Sweden)

    Xue Bin Zheng

    2016-12-01

    Full Text Available The objective of this study is to derive implications required for efficiency improvement and management level enhancement by selecting container terminals within major large ports of Korea and China as comparison units, evaluating their relative efficiencies and analyzing the trend of changes in their efficiencies. Since the scope of comparison subjects has been narrowed down to container terminals unlike previous studies, it is expected that the study results would have significant meaning due to the fact that it would be possible to compare and analyze in more detail. To achieve the objective, 30 major container terminals in both countries are selected, input and output variables are defined for each terminal and the DEA (data envelopment analysis model is used to conduct an analysis. The results show that the efficiency of major terminals in Korea (CCR: 0.815, BCC: 0.886 showed similar efficiency with China's terminals (CCR: 0.817, BCC: 0.887. While previous studies conclude that the efficiency of ports in Korea is far lower than that of ports in China.

  9. Effects of edge reconstruction on the common groups terminated zigzag phosphorene nanoribbon

    International Nuclear Information System (INIS)

    Xiao, Huaping; Guo, Sumei; Zhang, Chunxiao; He, Chaoyu; Zhong, Jianxin

    2017-01-01

    Edge configuration plays an important role in the electronic properties of nano-structures. In this work, we perform first-principles calculations to study the effects of the cooperation between neighbor groups on the edge configuration and the electronic properties of zigzag-PNRs (ZPNRs) terminated by common groups H, F, O, S and OH. We find that the cooperation has little effect on the H(F)-terminated ZPNRs, but gives rise to an edge reconstruction for the O(S)-terminated ZPNRs. The edge reconstruction derives from the repulsion between neighbor O atoms and the distortion of the P skeleton induced by the p state coupling among the edge, second edge and third edge P atoms. In comparison to the H-terminated ZPNRs, O-terminated ZPNRs are also a semiconductor and enlarge the band gap, but bring about an extra transport channel for the charge transport at the edge and decreases the effective mass of the electron and hole. OH-terminated ZPNRs also undergo a doubling of the unit cell (UC) along the periodic direction because of the different directions of the neighbor O–H bonds. In comparison with the H-terminated ZPNRs, OH-terminated ZPNRs show a similar band gap and electronic effective mass, but increase the effective mass of the hole. (paper)

  10. Technical forums as an instrument for knowledge management in oil pipelines and terminals companies: the experience of TRANSPETRO

    Energy Technology Data Exchange (ETDEWEB)

    Almeida, Maria Fatima Ludovico de [Pontificia Universidade Catolica do Rio de Janeiro (PUC-Rio/ITUC), Rio de Janeiro, RJ (Brazil). Instituto Tecnologico; Santiago, Adilson; Ribeiro, Kassandra Senra; Arruda, Daniela Mendonca [TRANSPETRO - PETROBRAS Transporte S.A., Rio de Janeiro, RJ (Brazil)

    2009-07-01

    This paper describes the experience of TRANSPETRO's Oil Pipelines and Terminals Unit regarding an institutionalized knowledge management (KM) process of systematically promoting technical forums focused on: pipeline and terminal operations; industrial maintenance; and right-of-way activities management. This empirical work adds evidence that in the model of cooperative and communicative knowledge management it is necessary to motivate staff to provide the company with their tacit knowledge and to take a proactive part in knowledge management processes, particularly in technical forums. Within this KM perspective, technical forums have been held by TRANSPETRO for the following purposes: to discuss the main barriers and challenges the oil pipelines and terminals unit has to face in the coming years; to share and disseminate good practices concerning oil pipeline and terminal activities; to discuss new processes, methods and equipment developments with potential application in business and operational processes; to establish action plans concerning the main challenges, barriers and opportunities; to disseminate Research and Development (R and D) projects in course, new procedures, methods and equipment and to promote integration among forum attendees. The two year-experience in TRANSPETRO's Oil Pipelines and Terminals Unit revealed that technical forums have been an important instrument for cooperative and communicative knowledge management, according to evaluations from 173 attendees. (author)

  11. Technical forums as an instrument for knowledge management in oil pipelines and terminals companies: the experience of TRANSPETRO

    Energy Technology Data Exchange (ETDEWEB)

    Almeida, Maria Fatima Ludovico de [Pontificia Universidade Catolica do Rio de Janeiro (PUC-Rio/ITUC), Rio de Janeiro, RJ (Brazil). Instituto Tecnologico; Santiago, Adilson; Ribeiro, Kassandra Senra; Arruda, Daniela Mendonca [TRANSPETRO - PETROBRAS Transporte S.A., Rio de Janeiro, RJ (Brazil)

    2009-07-01

    This paper describes the experience of TRANSPETRO's Oil Pipelines and Terminals Unit regarding an institutionalized knowledge management (KM) process of systematically promoting technical forums focused on: pipeline and terminal operations; industrial maintenance; and right-of-way activities management. This empirical work adds evidence that in the model of cooperative and communicative knowledge management it is necessary to motivate staff to provide the company with their tacit knowledge and to take a proactive part in knowledge management processes, particularly in technical forums. Within this KM perspective, technical forums have been held by TRANSPETRO for the following purposes: to discuss the main barriers and challenges the oil pipelines and terminals unit has to face in the coming years; to share and disseminate good practices concerning oil pipeline and terminal activities; to discuss new processes, methods and equipment developments with potential application in business and operational processes; to establish action plans concerning the main challenges, barriers and opportunities; to disseminate Research and Development (R and D) projects in course, new procedures, methods and equipment and to promote integration among forum attendees. The two year-experience in TRANSPETRO's Oil Pipelines and Terminals Unit revealed that technical forums have been an important instrument for cooperative and communicative knowledge management, according to evaluations from 173 attendees. (author)

  12. Orientations of terminal cladodes of Platyopuntias

    Energy Technology Data Exchange (ETDEWEB)

    Nobel, P.S.

    1982-01-01

    The orientations of terminal unshaded cladodes of 23 species of platyopuntias were observed in North America, South America, Australia, and Israel. When the seasonality of rainfall favored cladode development in the winter and the site was located above 27/sup 0/N, the cladodes tended to face north-south (five cases, P < .001 for each). In all other cases without topographical blockage of incoming radiation, the tendency was to face east-west. For example, terminal cladodes of Opuntia phaeacantha var. discata and O. stricta tended to face north-south in Israel but east-west in the United States (P > .001). Such dissimilar orientation patterns also occurred for cladodes of 0. chlorotica at two sites in the Sonoran Desert and for O. basilaris var. basilaris developing at different seasons at a single site. Contrary to previously published observations, cladodes of O. ficus-indica and O. compressa had a significant tendency to orient (P > .001). When topographical features affected the direction of prevailing photosynthetically active radiation (PAR), the preferred orientation of terminal cladodes was changed accordingly. The preferred direction always maximized the interception of PAR, which is often a limiting factor in the productivity of cacti, even in a putatively high radiation environment.

  13. Osteogenic cell differentiation on H-terminated and O-terminated nanocrystalline diamond films

    Directory of Open Access Journals (Sweden)

    Liskova J

    2015-01-01

    Full Text Available Jana Liskova,1 Oleg Babchenko,2 Marian Varga,2 Alexander Kromka,2 Daniel Hadraba,1 Zdenek Svindrych,1 Zuzana Burdikova,1 Lucie Bacakova1 1Institute of Physiology, Academy of Sciences of the Czech Republic, Prague, Czech Republic; 2Institute of Physics, Academy of Sciences of the Czech Republic, Prague, Czech Republic Abstract: Nanocrystalline diamond (NCD films are promising materials for bone implant coatings because of their biocompatibility, chemical resistance, and mechanical hardness. Moreover, NCD wettability can be tailored by grafting specific atoms. The NCD films used in this study were grown on silicon substrates by microwave plasma-enhanced chemical vapor deposition and grafted by hydrogen atoms (H-termination or oxygen atoms (O-termination. Human osteoblast-like Saos-2 cells were used for biological studies on H-terminated and O-terminated NCD films. The adhesion, growth, and subsequent differentiation of the osteoblasts on NCD films were examined, and the extracellular matrix production and composition were quantified. The osteoblasts that had been cultivated on the O-terminated NCD films exhibited a higher growth rate than those grown on the H-terminated NCD films. The mature collagen fibers were detected in Saos-2 cells on both the H-terminated and O-terminated NCD films; however, the quantity of total collagen in the extracellular matrix was higher on the O-terminated NCD films, as were the amounts of calcium deposition and alkaline phosphatase activity. Nevertheless, the expression of genes for osteogenic markers – type I collagen, alkaline phosphatase, and osteocalcin – was either comparable on the H-terminated and O-terminated films or even lower on the O-terminated films. In conclusion, the higher wettability of the O-terminated NCD films is promising for adhesion and growth of osteoblasts. In addition, the O-terminated surface also seems to support the deposition of extracellular matrix proteins and extracellular matrix

  14. Organizational Relationship Termination Competence

    DEFF Research Database (Denmark)

    Ritter, Thomas; Geersbro, Jens

    2011-01-01

    termination are found to significantly affect a firm's relationship termination competence. The findings suggest that managers should regard termination as a legitimate option in customer relationship management. In order to decrease the number of unwanted customers, managers must accept termination......Most firms are involved in a number of customer relationships that drain the firm's resources. However, many firms are hesitant to address this problem. This paper investigates customer relationship termination at the organizational level. We develop and analyze the organizational dimensions...... of organizational termination in order to improve our understanding of the management of termination. The impact of these termination dimensions on the percentage of unwanted customers is developed and tested using PLS on data gathered from a cross-sectional survey of more than 800 sales representatives. We find...

  15. Business process modeling applied to oil pipeline and terminal processes: a proposal for TRANSPETRO's oil pipelines and terminals in Rio de Janeiro and Minas Gerais

    Energy Technology Data Exchange (ETDEWEB)

    Santiago, Adilson da Silva [TRANSPETRO - PETROBRAS Transporte S.A., Rio de Janeiro, RJ (Brazil); Caulliraux, Heitor Mansur [Universidade Federal do Rio de Janeiro (COPPE/UFRJ/GPI), RJ (Brazil). Coordenacao de Pos-graduacao em Engenharia. Grupo de Producao Integrada; Almeida, Maria Fatima Ludovico de [Pontificia Universidade Catolica do Rio de Janeiro (PUC-Rio/ITUC), Rio de Janeiro, RJ (Brazil). Instituto Tecnologico; Felippe, Adriana Vieira de Oliveira [TRANSPETRO - PETROBRAS Transporte S.A., Rio de Janeiro, RJ (Brazil)

    2009-07-01

    Business process modeling (BPM) using event driven process chain diagrams (EPCs) to lay out business process work flows is now widely adopted around the world. The EPC method was developed within the framework of the ARIS Toolset developed by Prof. Wilhelm-August Scheer at the Institut fur Wirtschaftsinformatik at the Universitat des Saarlandes, in the early 1990s. It is used by many companies to model, analyze and redesign business processes. As such it forms the core technique for modeling in ARIS, which serves to link the different aspects of the so-called control view, which is discussed in the section on ARIS business process modeling. This paper describes a proposal made to TRANSPETRO's Oil Pipelines and Terminals Division in the states of Rio de Janeiro and Minas Gerais, which will be jointly developed by specialists and managers from TRANSPETRO and from COPPETEC, the collaborative research arm of Rio de Janeiro Federal University (UFRJ). The proposal is based on ARIS business process modeling and is presented here according to its seven phases, as follows: information survey and definition of the project structure; mapping and analysis of Campos Eliseos Terminal (TECAM) processes; validation of TECAM process maps; mapping and analysis of the remaining organizational units' processes; validation of the remaining organizational units' process maps; proposal of a business process model for all organizational units of TRANSPETRO's Oil Pipelines and Terminals Division in Rio de Janeiro and Minas Gerais; critical analysis of the process itself and the results and potential benefits of BPM. (author)

  16. Actuator digital interface unit (AIU). [control units for space shuttle data system

    Science.gov (United States)

    1973-01-01

    Alternate versions of the actuator interface unit are presented. One alternate is a dual-failure immune configuration which feeds a look-and-switch dual-failure immune hydraulic system. The other alternate is a single-failure immune configuration which feeds a majority voting hydraulic system. Both systems communicate with the data bus through data terminals dedicated to each user subsystem. Both operational control data and configuration control information are processed in and out of the subsystem via the data terminal which yields the actuator interface subsystem, self-managing within its failure immunity capability.

  17. α,β-D-constrained nucleic acids are strong terminators of thermostable DNA polymerases in polymerase chain reaction.

    Directory of Open Access Journals (Sweden)

    Olivier Martínez

    Full Text Available (S(C5', R(P α,β-D- Constrained Nucleic Acids (CNA are dinucleotide building blocks that can feature either B-type torsional angle values or non-canonical values, depending on their 5'C and P absolute stereochemistry. These CNA are modified neither on the nucleobase nor on the sugar structure and therefore represent a new class of nucleotide with specific chemical and structural characteristics. They promote marked bending in a single stranded DNA so as to preorganize it into a loop-like structure, and they have been shown to induce rigidity within oligonucleotides. Following their synthesis, studies performed on CNA have only focused on the constraints that this family of nucleotides introduced into DNA. On the assumption that bending in a DNA template may produce a terminator structure, we investigated whether CNA could be used as a new strong terminator of polymerization in PCR. We therefore assessed the efficiency of CNA as a terminator in PCR, using triethylene glycol phosphate units as a control. Analyses were performed by denaturing gel electrophoresis and several PCR products were further analysed by sequencing. The results showed that the incorporation of only one CNA was always skipped by the polymerases tested. On the other hand, two CNA units always stopped proofreading polymerases, such as Pfu DNA polymerase, as expected for a strong replication terminator. Non-proofreading enzymes, e.g. Taq DNA polymerase, did not recognize this modification as a strong terminator although it was predominantly stopped by this structure. In conclusion, this first functional use of CNA units shows that these modified nucleotides can be used as novel polymerization terminators of proofreading polymerases. Furthermore, our results lead us to propose that CNA and their derivatives could be useful tools for investigating the behaviour of different classes of polymerases.

  18. Terminal weather information management

    Science.gov (United States)

    Lee, Alfred T.

    1990-01-01

    Since the mid-1960's, microburst/windshear events have caused at least 30 aircraft accidents and incidents and have killed more than 600 people in the United States alone. This study evaluated alternative means of alerting an airline crew to the presence of microburst/windshear events in the terminal area. Of particular interest was the relative effectiveness of conventional and data link ground-to-air transmissions of ground-based radar and low-level windshear sensing information on microburst/windshear avoidance. The Advanced Concepts Flight Simulator located at Ames Research Center was employed in a line oriented simulation of a scheduled round-trip airline flight from Salt Lake City to Denver Stapleton Airport. Actual weather en route and in the terminal area was simulated using recorded data. The microburst/windshear incident of July 11, 1988 was re-created for the Denver area operations. Six experienced airline crews currently flying scheduled routes were employed as test subjects for each of three groups: (1) A baseline group which received alerts via conventional air traffic control (ATC) tower transmissions; (2) An experimental group which received alerts/events displayed visually and aurally in the cockpit six miles (approx. 2 min.) from the microburst event; and (3) An additional experimental group received displayed alerts/events 23 linear miles (approx. 7 min.) from the microburst event. Analyses of crew communications and decision times showed a marked improvement in both situation awareness and decision-making with visually displayed ground-based radar information. Substantial reductions in the variability of decision times among crews in the visual display groups were also found. These findings suggest that crew performance will be enhanced and individual differences among crews due to differences in training and prior experience are significantly reduced by providing real-time, graphic display of terminal weather hazards.

  19. 28 CFR 0.190 - Changes within organizational units.

    Science.gov (United States)

    2010-07-01

    ... 28 Judicial Administration 1 2010-07-01 2010-07-01 false Changes within organizational units. 0... JUSTICE Sections and Subunits § 0.190 Changes within organizational units. (a) The head of each Office... termination of major functions within his organizational unit as he may deem necessary or appropriate. In each...

  20. An overlapping region between the two terminal folding units of the outer surface protein A (OspA) controls its folding behavior.

    Science.gov (United States)

    Makabe, Koki; Nakamura, Takashi; Dhar, Debanjan; Ikura, Teikichi; Koide, Shohei; Kuwajima, Kunihiro

    2018-04-27

    Although many naturally occurring proteins consist of multiple domains, most studies on protein folding to date deal with single-domain proteins or isolated domains of multi-domain proteins. Studies of multi-domain protein folding are required for further advancing our understanding of protein folding mechanisms. Borrelia outer surface protein A (OspA) is a β-rich two-domain protein, in which two globular domains are connected by a rigid and stable single-layer β-sheet. Thus, OspA is particularly suited as a model system for studying the interplays of domains in protein folding. Here, we studied the equilibria and kinetics of the urea-induced folding-unfolding reactions of OspA probed with tryptophan fluorescence and ultraviolet circular dichroism. Global analysis of the experimental data revealed compelling lines of evidence for accumulation of an on-pathway intermediate during kinetic refolding and for the identity between the kinetic intermediate and a previously described equilibrium unfolding intermediate. The results suggest that the intermediate has the fully native structure in the N-terminal domain and the single layer β-sheet, with the C-terminal domain still unfolded. The observation of the productive on-pathway folding intermediate clearly indicates substantial interactions between the two domains mediated by the single-layer β-sheet. We propose that a rigid and stable intervening region between two domains creates an overlap between two folding units and can energetically couple their folding reactions. Copyright © 2018. Published by Elsevier Ltd.

  1. Circulating sex hormones and terminal duct lobular unit involution of the normal breast.

    Science.gov (United States)

    Khodr, Zeina G; Sherman, Mark E; Pfeiffer, Ruth M; Gierach, Gretchen L; Brinton, Louise A; Falk, Roni T; Patel, Deesha A; Linville, Laura M; Papathomas, Daphne; Clare, Susan E; Visscher, Daniel W; Mies, Carolyn; Hewitt, Stephen M; Storniolo, Anna Maria V; Rosebrock, Adrian; Caban, Jesus J; Figueroa, Jonine D

    2014-12-01

    Terminal duct lobular units (TDLU) are the predominant source of breast cancers. Lesser degrees of age-related TDLU involution have been associated with increased breast cancer risk, but factors that influence involution are largely unknown. We assessed whether circulating hormones, implicated in breast cancer risk, are associated with levels of TDLU involution using data from the Susan G. Komen Tissue Bank (KTB) at the Indiana University Simon Cancer Center (2009-2011). We evaluated three highly reproducible measures of TDLU involution, using normal breast tissue samples from the KTB (n = 390): TDLU counts, median TDLU span, and median acini counts per TDLU. RRs (for continuous measures), ORs (for categorical measures), 95% confidence intervals (95% CI), and Ptrends were calculated to assess the association between tertiles of estradiol, testosterone, sex hormone-binding globulin (SHBG), progesterone, and prolactin with TDLU measures. All models were stratified by menopausal status and adjusted for confounders. Among premenopausal women, higher prolactin levels were associated with higher TDLU counts (RRT3vsT1:1.18; 95% CI: 1.07-1.31; Ptrend = 0.0005), but higher progesterone was associated with lower TDLU counts (RRT3vsT1: 0.80; 95% CI: 0.72-0.89; Ptrend < 0.0001). Among postmenopausal women, higher levels of estradiol (RRT3vsT1:1.61; 95% CI: 1.32-1.97; Ptrend < 0.0001) and testosterone (RRT3vsT1: 1.32; 95% CI: 1.09-1.59; Ptrend = 0.0043) were associated with higher TDLU counts. These data suggest that select hormones may influence breast cancer risk potentially through delaying TDLU involution. Increased understanding of the relationship between circulating markers and TDLU involution may offer new insights into breast carcinogenesis. Cancer Epidemiol Biomarkers Prev; 23(12); 2765-73. ©2014 AACR. ©2014 American Association for Cancer Research.

  2. 77 FR 75631 - Halofenozide; Cancellation Order for All Pesticide Registrations and Termination of All Uses

    Science.gov (United States)

    2012-12-21

    ... existing stocks of the products identified in Table 1 of Unit II. in a manner inconsistent with any of the... registrants listed in Table 2 of Unit II. to voluntarily cancel and terminate all uses of these product... under FIFRA section 3. These registrations are listed in sequence by registration number in Table 1 of...

  3. CONTAINER TERMINALS IN EUROPE

    Directory of Open Access Journals (Sweden)

    Bart W. WIEGMANS

    2001-01-01

    Full Text Available This paper aims to address the linkage between logistics (in particular, the management of marketing channel flows and transport markets, while also the interaction between these two markets and intermodal container terminals is analysed. The marketing channel theory is used to describe all relevant actors and flows that run through marketing channels, starting with customer needs and ending with customer satisfaction. Porter's theory of competitive advantages is used to review competitive forces in both markets. Finally, a competitor analysis is performed for the logistics and transport market. These theories are applied so as to be able to determine the competitive position of intermodal container terminals with a view to the management of marketing channel flows and the physical transport of freight flows. Hence, the central question of this paper is: Which markets are served by intermodal container terminals and with whom are they competing? At present, neither the maritime container terminals nor the continental container terminals appear to have a significant influence in the logistics service market; they concentrate mainly on the physical movement of containers (transshipment. Furthermore, maritime container terminals and continental container terminals are not dominant players in the transport service market. Our conclusion is that continental terminals are predominantly competing with unimodal road transport, with neighbouring continental terminals and with barge transport companies.

  4. Visual operations management tools applied to the oil pipelines and terminals standardization process: the experience of TRANSPETRO

    Energy Technology Data Exchange (ETDEWEB)

    Almeida, Maria Fatima Ludovico de [Pontificia Universidade Catolica do Rio de Janeiro (PUC-Rio/ITUC), Rio de Janeiro, RJ (Brazil). Instituto Tecnologico; Santiago, Adilson; Ribeiro, Kassandra Senra; Arruda, Daniela Mendonca [TRANSPETRO - PETROBRAS Transporte S.A., Rio de Janeiro, RJ (Brazil)

    2009-07-01

    This paper describes the process by which visual operations management (VOM) tools were implemented, concerning standards and operational procedures in TRANSPETRO's Oil Pipelines and Terminals Unit. It provides: a brief literature review of visual operations management tools applied to total quality management and the standardization processes; a discussion of the assumptions from the second level of VOM (visual standards) upon which TRANSPETRO's oil pipelines and terminals business processes and operational procedures are based; and a description of the VOM implementation process involving more than 100 employees and one illustrative example of 'Quick Guides' for right-of- way management activities. Finally, it discusses the potential impacts and benefits of using VOM tools in the current practices in TRANSPETRO's Oil Pipelines and Terminals Unit, reinforcing the importance of such visual guides as vital to implement regional and corporate procedures, focusing on the main operational processes. (author)

  5. Termination of the Special Metallurgical (SM) Building at Mound Laboratory: a final report

    International Nuclear Information System (INIS)

    Harris, W.R.; Kokenge, B.R.; Marsh, G.C.

    1976-01-01

    The report describes and highlights the more important factors associated with the termination of the Special Metallurgical (SM) Building at Mound Laboratory. As a result, a written record of the more important techniques and procedures is now available for reference by others involved in similar termination efforts. Included in this report is a description of the organizational units that were used in this effort along with a description of their responsibilities. A general description of the SM Building and a discussion of the more relevant procedures and equipment that were used are also presented. In addition, pertinent Health Physics information, such as personnel exposure, final wipe levels in the terminated facility, and assays of the structure, are provided. Based on the experience gained from this project, recommendations were made regarding the design of future radioactive material handling facilities so that when they are ultimately terminated the effort can be accomplished more efficiently

  6. Visual communication and terminal equipment

    International Nuclear Information System (INIS)

    Kang, Cheol Hui

    1988-06-01

    This book is divided two parts about visual communication and terminal equipment. The first part introduces visual communication, which deals with foundation of visual communication, technique of visual communication, equipment of visual communication, a facsimile and pictorial image system. The second part contains terminal equipment such as telephone, terminal equipment for data transmission on constitution and constituent of terminal equipment for data transmission, input device and output device, terminal device and up-to-date terminal device.

  7. Visual communication and terminal equipment

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Cheol Hui

    1988-06-15

    This book is divided two parts about visual communication and terminal equipment. The first part introduces visual communication, which deals with foundation of visual communication, technique of visual communication, equipment of visual communication, a facsimile and pictorial image system. The second part contains terminal equipment such as telephone, terminal equipment for data transmission on constitution and constituent of terminal equipment for data transmission, input device and output device, terminal device and up-to-date terminal device.

  8. 77 FR 74513 - Certain CMOS Image Sensors and Products Containing Same; Investigations: Terminations...

    Science.gov (United States)

    2012-12-14

    ... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-846] Certain CMOS Image Sensors and Products Containing Same; Investigations: Terminations, Modifications and Rulings AGENCY: U.S... United States after importation of certain CMOS image sensors and products containing the same based on...

  9. Is pregnancy termination being used as a family planning method in ...

    African Journals Online (AJOL)

    Background: This study determined the profile of women seeking termination of pregnancy (TOP) in the Free State and whether TOP was used as a family planning method. Methods: Seven hundred and fifty women (15-47 years old) seeking TOP at the Reproductive Health Unit of the National Hospital in Bloemfontein were ...

  10. WAR TERMINATION IN SOMALIA AND KENYA DEFENSE FORCES’ (KDF ROLE

    Directory of Open Access Journals (Sweden)

    E.O.S. ODHIAMBO

    2013-01-01

    Full Text Available War causes and conduct have fascinated war planners, war executors and scholars for a long time because little attention has been given to how wars are ended. This oversight is apparent not only in historical accounts of warfare but, more importantly, in contemporary analyses and doctrinal formulations of deterrence and overall defense policies. Just as historians have focused on how wars begin and are fought, military analysts and planners have concentrated on influencing the initiation and conduct of warfare rather than on analyzing the process and requirements for terminating warfare on acceptable terms and at acceptable costs. Conflict termination is the formal end of fighting, not the end of conflict. Despite the volumes of research and literature on the subject, belligerents mismanage war termination. The major objective of wartime strategy is defeating enemy arms as quickly as possible with the least cost in friendly casualties. As long as hostilities endure, diplomacy is subordinated to military requirements. War termination planning, as it is currently accomplished, takes the form of civil affair planning on the details of how the vanquished will be managed following the capitulation of the enemy and cessation of hostilities. We argue that Kenya Defence Forces (KDF prudently terminated its war with the terrorists group Al-Shabaab that merged with Al-Qaeda when they agreed to be integrated into the African Union Mission for Somalia (AMISOM which is backed up by the United Nations.

  11. Grain intermodal terminals: evaluation of pure technical efficiency by Data Envelopment Analysis

    Directory of Open Access Journals (Sweden)

    Maria Gabriela Mendonça Peixoto

    Full Text Available Abstract This paper aimed to verify if terminals with productive efficiency also have pure technical efficiency, using DEA (Data Envelopment Analysis technique. The research approach was the qualitative-quantitative or mixed, with exploratory purpose; the research method defined was the case study (multicases; data were collected through interviews using a structured questionnaire and non-probability for convenience sampling. While the application of Charnes, Cooper and Rhodes (CCR model observed that only three (4, 7 and 11, of the twelve analyzed Decision Making Units (DMUs have total technical efficiency, through Banker, Charnes and Cooper (BCC model, it was possible to observe that these terminals were the only ones with pure technical efficiency. The three inefficient DMUs (1, 2 and 12 showed pure technical efficiency, suggesting that these terminals might present probable scale operations’ inefficiency, aspect not addressed in this paper.

  12. Dust settles at Dalrymple Bay Terminal

    International Nuclear Information System (INIS)

    2006-01-01

    With an annual loading capacity approaching 60Mt, Queensland's Dalrymple Bay Coal Terminal is one of the largest and most efficient coal export facilities in Australia. Each day, DBCT handles thousands of tonnes of coal transported directly from the Bowen Basin via an electrified railway and bound, ultimately, for out-loading onto bulk carrier ships. It is little wonder then that dust control and an accurate knowledge of coal moisture content are key priorities for DBCT. In early 2004, these priorities, together with an undertaking to the Co-ordinator General to reduce dust emissions, saw DBCT investigate the CSIRO-developed Low Frequency Microwave (LFM) Moisture Analyser. The LFM Analyser is specifically designed to deliver accurate, online measurements of moisture in continuous on-conveyor applications. At this stage, it was already enjoying significant success in the iron ore market with BHP Billiton Iron Ore investing in multiple units as part of its moisture control strategy for the Marra Mamba ore-types. The LFM Analysers, now being commercialised by spin-out company Intalysis, were commissioned in July 2004. Babcock and Brown Infrastructure (BBI), the company that holds the long-term leasehold of DBCT, was heavily involved in the analyser's commissioning. BBI's electrical supervisor Doug Mitchell says the analyser offers the means for DBCT to meet the environmental conditions of the terminal license while at the same time enabling it to meet its individual contract obligations with the terminal customers. 'This basically involves ensuring the moisture content for each coal type does not exceed that which has been agreed upon with terminal customer,' Mitchell says. DBCT has installed two analysers on the in loading conveyors, each about 100m from the coal discharge hoppers. They are fitted to steel cord belts at a nominal speed of around 6m/sec that carry the coal to either 4250tph or 5500tph yard stacking machines, depending on the string selected for

  13. Liquid crystals with novel terminal chains as ferroelectric liquid crystal hosts

    International Nuclear Information System (INIS)

    Cosquer, G.Y.

    2000-02-01

    Changes to the molecular structure of liquid crystals can have a significant effect upon their mesomorphism and ferroelectric properties. Most of the research in liquid crystal for display applications concentrates on the design and synthesis of novel mesogenic cores to which straight terminal alkyl or alkoxy chains are attached. However, little is known about the effects upon the mesomorphism and ferroelectric properties of varying the terminal chains. The compounds prepared in this work have a common core - a 2,3-difluoroterphenyl unit with a nine-atom alkyl (nonyl) or alkoxy (octyloxy) chain at the 4-position, but with an unusual chain at the 4''-position. In some cases the terminal chain contains hetero atoms such as silicon, oxygen, chlorine and bromine or has a bulky end group. In total 46 final materials were synthesised in an attempt to understand the effect of an unusual terminal chains on mesomorphism and for some of these compounds the effect upon the switching times when added to a standard ferroelectric mixture were investigated. It was found that most compounds containing a bulky end group only displayed a smectic C phase, compounds with a halogen substituent as an end unit displayed a smectic A phase and that increasing the chain flexibility by introducing an oxygen atom in the chain reduces the melting and clearing points. The electro-optical measurements carried out on ferroelectric mixtures containing a bulky end group compound showed that shorter switching times were produced than for the ferroelectric mixture containing a straight chain compound. It is suggested that a bulky end group diminishes te extent of interlayer mixing in the chiral smectic C phase and therefore the molecules move more easily with ferroelectric switching. (author)

  14. Visual operations management tools applied to the oil pipelines and terminals standardization process: the experience of TRANSPETRO

    Energy Technology Data Exchange (ETDEWEB)

    Almeida, Maria Fatima Ludovico de [Pontificia Universidade Catolica do Rio de Janeiro (PUC-Rio/ITUC), Rio de Janeiro, RJ (Brazil). Instituto Tecnologico; Santiago, Adilson; Ribeiro, Kassandra Senra; Arruda, Daniela Mendonca [TRANSPETRO - PETROBRAS Transporte S.A., Rio de Janeiro, RJ (Brazil)

    2009-07-01

    This paper describes the process by which visual operations management (VOM) tools were implemented, concerning standards and operational procedures in TRANSPETRO's Oil Pipelines and Terminals Unit. It provides: a brief literature review of visual operations management tools applied to total quality management and the standardization processes; a discussion of the assumptions from the second level of VOM (visual standards) upon which TRANSPETRO's oil pipelines and terminals business processes and operational procedures are based; and a description of the VOM implementation process involving more than 100 employees and one illustrative example of 'Quick Guides' for right-of- way management activities. Finally, it discusses the potential impacts and benefits of using VOM tools in the current practices in TRANSPETRO's Oil Pipelines and Terminals Unit, reinforcing the importance of such visual guides as vital to implement regional and corporate procedures, focusing on the main operational processes. (author)

  15. Antecedents of Customer Relationship Termination

    DEFF Research Database (Denmark)

    Geersbro, Jens; Ritter, Thomas

    To end business relationships, or to more actively terminate relationships, has long been acknowledged as part of customer relationship management. However, compared to other elements such as initiation and maintenance of relationships, little is known about the termination of business...... relationships as a managerial task. This paper contributes by (1) developing a conceptualization of relationship termination competence and (2) analyzing its antecedents. The empirical results identify termination acceptance, definition non-customers, organizational relationship termination routines......, and motivation as significant antecedents. Because of this, managers need to develop their organizations in order to use relationship termination as a vital strategy....

  16. Evaluation unit of X-ray spectrometer

    International Nuclear Information System (INIS)

    Polivka, V.

    1986-01-01

    The evaluation unit is designed as a CAMAC modular system. It processes analog signals from the detector, amplifies them, digitizes them, stores them, and displays them. The analog data collection system consists of a high voltage supply, a linear amplifier, and an analog-to-digital convertor. The digital part of the data collection system consists of a data memory and a mapping unit. The control and calculation system consisting of a controller, a memory, an expandable working memory, a floppy disk controller, a parallel input and output for the terminal, and a controller for block transfer, provides the control of the entire spectrometer and the calculations for qualitative and quantitative analyses. It also provides connection to the peripherals: the disk operating system, the graphics terminal with keyboard, and the mosaic printer. (M.D.)

  17. Saateks / Maia Muldma, Maie Vikat

    Index Scriptorium Estoniae

    Muldma, Maia

    2008-01-01

    2007. a. 20. märtsil toimus rahvusvaheline konverents "Mitmekultuuriline õpikeskkond - probleem või väärtus?". Kogumik sisaldab konverentsimaterjale, mille temaatika on ajendatud mitmekultuurilise keskkonna edendamisvõimalustest

  18. 76 FR 29238 - Methyl Bromide; Cancellation Order for Registration Amendments To Terminate Certain Soil Uses

    Science.gov (United States)

    2011-05-20

    ...This notice announces EPA's order for the amendments to terminate soil uses, voluntarily requested by the registrants and accepted by the Agency, of products containing methyl bromide, pursuant to section 6(f)(1) of the Federal Insecticide, Fungicide, and Rodenticide Act (FIFRA), as amended. This cancellation order follows a February 9, 2011, Federal Register Notice of Receipt of Requests from the registrants listed in Table 2 of Unit II to voluntarily amend to terminate uses of these product registrations. These are not the last products containing this pesticide registered for use in the United States. In that notice, EPA indicated that it would issue an order implementing the amendments to terminate uses, unless the Agency received substantive comments within the 30-day comment period that would merit its further review of these requests, or unless the registrants withdrew their requests. The Agency did not receive any comments on the notice. Further, the registrants did not withdraw their requests. These amendments do not affect post-harvest fumigant uses. Any distribution, sale, or use of the products subject to this cancellation order is permitted only in accordance with the terms of this order, including any existing stocks provisions.

  19. LNG TERMINAL SAFE OPERATION MANAGEMENT

    Directory of Open Access Journals (Sweden)

    Andrzej ADAMKIEWICZ

    2012-07-01

    Full Text Available This article presents the significance of LNG terminal safety issues in natural gas sea transport. It shows particular requirements for LNG transmission installations resulting from the specific properties of LNG. Out of the multi‐layer critical safety areas comprising structural elements of the terminal safety system, possibilities to decrease the risk of emergency occurrence on LNG terminals have been selected. Tasks performed by the LNG terminal, together with its own personnel and the outside one, have been defined. General theses for LNG terminal safety have been formulated.

  20. 76 FR 55161 - Boston and Maine Corporation-Abandonment Exemption-Middlesex County, Mass.; Springfield Terminal...

    Science.gov (United States)

    2011-09-06

    ...\\ Docket No. AB 355; Sub-No. 39X] Boston and Maine Corporation--Abandonment Exemption--Middlesex County, Mass.; Springfield Terminal Railway Company; Discontinuance of Service Exemption; Middlesex County, MA... Middlesex County, Mass. The line traverses United States Postal Service Zip Codes 02471 and 02138...

  1. Nonleaking battery terminals.

    Science.gov (United States)

    Snider, W. E.; Nagle, W. J.

    1972-01-01

    Three different terminals were designed for usage in a 40 ampere/hour silver zinc battery which has a 45% KOH by weight electrolyte in a plastic battery case. Life tests, including thermal cycling, electrical charge and discharge for up to three years duration, were conducted on these three different terminal designs. Tests for creep rate and tensile strength were conducted on the polyphenylene oxide plastic battery cases. Some cases were unused and others containing KOH electrolyte were placed on life tests. The design and testing of nonleaking battery terminals for use with a KOH electrolyte in a plastic case are considered.

  2. Architecture of vagal motor units controlling striated muscle of esophagus: peripheral elements patterning peristalsis?

    Science.gov (United States)

    Powley, Terry L; Mittal, Ravinder K; Baronowsky, Elizabeth A; Hudson, Cherie N; Martin, Felecia N; McAdams, Jennifer L; Mason, Jacqueline K; Phillips, Robert J

    2013-12-01

    Little is known about the architecture of the vagal motor units that control esophageal striated muscle, in spite of the fact that these units are necessary, and responsible, for peristalsis. The present experiment was designed to characterize the motor neuron projection fields and terminal arbors forming esophageal motor units. Nucleus ambiguus compact formation neurons of the rat were labeled by bilateral intracranial injections of the anterograde tracer dextran biotin. After tracer transport, thoracic and abdominal esophagi were removed and prepared as whole mounts of muscle wall without mucosa or submucosa. Labeled terminal arbors of individual vagal motor neurons (n=78) in the esophageal wall were inventoried, digitized and analyzed morphometrically. The size of individual vagal motor units innervating striated muscle, throughout thoracic and abdominal esophagus, averaged 52 endplates per motor neuron, a value indicative of fine motor control. A majority (77%) of the motor terminal arbors also issued one or more collateral branches that contacted neurons, including nitric oxide synthase-positive neurons, of local myenteric ganglia. Individual motor neuron terminal arbors co-innervated, or supplied endplates in tandem to, both longitudinal and circular muscle fibers in roughly similar proportions (i.e., two endplates to longitudinal for every three endplates to circular fibers). Both the observation that vagal motor unit collaterals project to myenteric ganglia and the fact that individual motor units co-innervate longitudinal and circular muscle layers are consistent with the hypothesis that elements contributing to peristaltic programming inhere, or are "hardwired," in the peripheral architecture of esophageal motor units. © 2013.

  3. Crystallization and preliminary crystallographic studies of the C-terminal domain of outer membrane protein A from enterohaemorrhagic Escherichia coli

    International Nuclear Information System (INIS)

    Gu, Jiang; Ji, Xiaowei; Qi, Jianxun; Ma, Ying; Mao, Xuhu; Zou, Quanming

    2010-01-01

    In this study, recombinant OmpAC from EHEC was purified and crystallized and a diffraction data set was collected to 2.7 Å resolution. Outer membrane protein A (OmpA) of enterohaemorrhagic Escherichia coli (EHEC) plays multiple roles in bacterial physiology and pathogenesis, such as mediation of bacterial conjunction, maintenance of cell shape, induction of adhesion of EHEC to host cells etc. Better understanding of the functions of OmpA will help in the control of EHEC infections. OmpA is composed of two domains: the N-terminal domain and the C-terminal domain. The N-terminal domain is a β-barrel structure and embeds in the outer membrane of the bacterium. The structure and function of the C-terminal domain of OmpA (OmpAC) remain elusive. In this study, recombinant OmpAC from EHEC was purified and crystallized and a diffraction data set was collected to 2.7 Å resolution. The crystals belonged to space group I4 1 32, with unit-cell parameter a = 158.99 Å. The Matthews coefficient and solvent content were calculated to be 2.55 Å 3 Da −1 and 51.77%, respectively, for two molecules in the asymmetric unit

  4. LNG TERMINAL SAFE OPERATION MANAGEMENT

    OpenAIRE

    Andrzej ADAMKIEWICZ; Włodzimierz KAMIŃSKI

    2012-01-01

    This article presents the significance of LNG terminal safety issues in natural gas sea transport. It shows particular requirements for LNG transmission installations resulting from the specific properties of LNG. Out of the multi‐layer critical safety areas comprising structural elements of the terminal safety system, possibilities to decrease the risk of emergency occurrence on LNG terminals have been selected. Tasks performed by the LNG terminal, together with its own personnel and the out...

  5. Crystallization and preliminary X-ray characterization of the eukaryotic replication terminator Reb1-Ter DNA complex.

    Science.gov (United States)

    Jaiswal, Rahul; Singh, Samarendra K; Bastia, Deepak; Escalante, Carlos R

    2015-04-01

    The Reb1 protein from Schizosaccharomyces pombe is a member of a family of proteins that control programmed replication termination and/or transcription termination in eukaryotic cells. These events occur at naturally occurring replication fork barriers (RFBs), where Reb1 binds to termination (Ter) DNA sites and coordinates the polar arrest of replication forks and transcription approaching in opposite directions. The Reb1 DNA-binding and replication-termination domain was expressed in Escherichia coli, purified and crystallized in complex with a 26-mer DNA Ter site. Batch crystallization under oil was required to produce crystals of good quality for data collection. Crystals grew in space group P2₁, with unit-cell parameters a = 68.9, b = 162.9, c = 71.1 Å, β = 94.7°. The crystals diffracted to a resolution of 3.0 Å. The crystals were mosaic and required two or three cycles of annealing. This study is the first to yield structural information about this important family of proteins and will provide insights into the mechanism of replication and transcription termination.

  6. Korporatiivne maine loob väärtust / Charles J Fombrun

    Index Scriptorium Estoniae

    Fombrun, Charles J

    2002-01-01

    Autor põhjendab, miks heal mainel on majanduslik väärtus, toob välja 6 kategooriat tunnuseid, mis iseloomustavad inimestele meeldivaid ja ebameeldivaid firmasid ning 5 meetodit ettevõtte maine kujundamiseks

  7. 78 FR 4438 - Investigations: Terminations, Modifications and Rulings: Certain Electronic Devices With Graphics...

    Science.gov (United States)

    2013-01-22

    ... United States patents. The notice of investigation named Apple Inc. of Cupertino, California (``Apple''), as the only respondent. On November 19, 2012, S3G and Apple filed a joint motion to terminate the... West Indies, and S3 Graphics, Inc., of Fremont, California (collectively, ``S3G''). 76 FR 70490 (Nov...

  8. Digital Autonomous Terminal Access Communication (DATAC) system

    Science.gov (United States)

    Novacki, Stanley M., III

    1987-01-01

    In order to accommodate the increasing number of computerized subsystems aboard today's more fuel efficient aircraft, the Boeing Co. has developed the DATAC (Digital Autonomous Terminal Access Control) bus to minimize the need for point-to-point wiring to interconnect these various systems, thereby reducing total aircraft weight and maintaining an economical flight configuration. The DATAC bus is essentially a local area network providing interconnections for any of the flight management and control systems aboard the aircraft. The task of developing a Bus Monitor Unit was broken down into four subtasks: (1) providing a hardware interface between the DATAC bus and the Z8000-based microcomputer system to be used as the bus monitor; (2) establishing a communication link between the Z8000 system and a CP/M-based computer system; (3) generation of data reduction and display software to output data to the console device; and (4) development of a DATAC Terminal Simulator to facilitate testing of the hardware and software which transfer data between the DATAC's bus and the operator's console in a near real time environment. These tasks are briefly discussed.

  9. Volume of hydration in terminal cancer patients.

    Science.gov (United States)

    Bruera, E; Belzile, M; Watanabe, S; Fainsinger, R L

    1996-03-01

    In this retrospective study we reviewed the volume and modality of hydration of consecutive series of terminal cancer patients in two different settings. In a palliative care unit 203/290 admitted patients received subcutaneous hydration for 12 +/- 8 days at a daily volume of 1015 +/- 135 ml/day. At the cancer center, 30 consecutive similar patients received intravenous hydration for 11.5 +/- 5 days (P > 0.2) but at a daily volume of 2080 +/- 720 ml/day (P palliative care unit patients required discontinuation of hydration because of complications. Hypodermoclysis was administered mainly as a continuous infusion, an overnight infusion, or in one to three 1-h boluses in 62 (31%), 98 (48%) and 43 (21%) patients, respectively. Our findings suggest that, in some settings, patients may be receiving excessive volumes of hydration by less comfortable routes such as the intravenous route. Increased education and research in this area are badly needed.

  10. 76 FR 69762 - Limited Exclusion and Cease and Desist Orders; Terminations of Investigations: Certain Biometric...

    Science.gov (United States)

    2011-11-09

    ... Desist Orders; Terminations of Investigations: Certain Biometric Scanning Devices, Components Thereof... 11, 2010, by Cross Match Technologies, Inc. (``Cross Match'') of Palm Beach Gardens, Florida. 75 FR... importation, and the sale within the United States after importation of certain biometric scanning devices...

  11. Mida mõtleb professor Andrew Mayo? / Anne-Mari Ernesaks

    Index Scriptorium Estoniae

    Ernesaks, Anne-Mari

    2005-01-01

    PARE koordinaator tutvustab tuntud inimkapitali ideoloogi Andrew Mayo raamatut "Ettevõtte inimväärtus". Raamatu autori hinnangul on tänapäeva organisatsioonides juhtimise olulisim ülesanne inimese juhtimine varana. Lisa: Konverents

  12. Expression, crystallization and preliminary crystallographic study of mouse hepatitis virus (MHV) nucleocapsid protein C-terminal domain

    International Nuclear Information System (INIS)

    Tong, Xiaohang; Ma, Yanlin; Li, Xuemei

    2010-01-01

    The C-terminal domain of mouse hepatitis virus nucleocapsid protein has been overexpressed in E. coli, purified and crystallized. The crystal belonged to space group P422, with unit-cell parameters a = 66.6, c = 50.8 Å, and diffracted to 2.20 Å resolution. Mouse hepatitis virus (MHV) belongs to the group II coronaviruses. The virus produces nine genes encoding 11 proteins that could be recognized as structural proteins and nonstructural proteins and are crucial for viral RNA synthesis. The nucleocapsid (N) protein, one of the structural proteins, interacts with the 30.4 kb virus genomic RNA to form the helical nucleocapsid and associates with the membrane glycoprotein via its C-terminus to stabilize virion assembly. Here, the expression and crystallization of the MHV nucleocapsid protein C-terminal domain are reported. The crystals diffracted to 2.20 Å resolution and belonged to space group P422, with unit-cell parameters a = 66.6, c = 50.8 Å. Assuming the presence of two molecules in the asymmetric unit, the solvent content is 43.0% (V M = 2.16 Å 3 Da −1 )

  13. klax Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  14. kprc Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  15. katl Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  16. kmcn Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  17. kogb Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  18. kama Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  19. ptkk Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  20. kiwa Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  1. kavp Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  2. kdca Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  3. kbwg Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  4. kdfw Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  5. kssi Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  6. pahn Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  7. ksrq Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  8. kpvd Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  9. kisp Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  10. kttd Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  11. pmdy Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  12. kmgm Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  13. khib Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  14. pavd Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  15. kfar Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  16. kluk Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  17. kwwr Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  18. klse Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  19. ksts Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  20. koth Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  1. kbfl Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  2. ksgf Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  3. klch Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  4. kpkb Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  5. krog Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  6. kbjc Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  7. ksea Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  8. kbwi Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  9. kftw Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  10. kpuw Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  11. kabq Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  12. ksny Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  13. khio Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  14. klaf Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  15. kfoe Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  16. ksmx Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  17. kipt Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  18. ktrk Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  19. kwmc Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  20. katy Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  1. tjmz Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  2. kdet Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  3. kcxp Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  4. kbur Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  5. krkd Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  6. pawg Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  7. kloz Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  8. kcec Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  9. kdec Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  10. paor Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  11. kavl Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  12. kdrt Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  13. kstl Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  14. kbfi Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  15. khsv Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  16. pafa Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  17. kekn Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  18. tncm Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  19. kith Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  20. kgnv Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  1. ktoi Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  2. kgso Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  3. nstu Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  4. kpbi Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  5. kgdv Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  6. kcmx Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  7. kdls Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  8. koaj Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  9. krhi Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  10. kbpk Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  11. khuf Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  12. kont Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  13. kyng Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  14. kcwa Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  15. kflg Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  16. ktup Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  17. ktop Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  18. kink Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  19. krut Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  20. kbli Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  1. kaoo Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  2. klit Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  3. panc Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  4. ktcl Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  5. pgwt Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  6. kpsp Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  7. kbih Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  8. kdnl Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  9. kart Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  10. kilm Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  11. kpne Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  12. kabi Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  13. ptpn Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  14. kblf Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  15. kosh Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  16. kpdt Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  17. kewr Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  18. kiso Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  19. kpga Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  20. kbkw Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  1. kmyl Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  2. krbg Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  3. kril Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  4. ksus Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  5. padq Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  6. kbil Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  7. krfd Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  8. kdug Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  9. ktix Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  10. kcod Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  11. kslk Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  12. kgfl Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  13. kguc Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  14. kmlu Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  15. kbff Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  16. ksmn Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  17. kdro Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  18. kmce Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  19. ktpa Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  20. kmot Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  1. kcre Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  2. klws Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  3. kotm Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  4. khqm Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  5. kabr Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  6. klal Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  7. kelp Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  8. kecg Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  9. khbg Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  10. kpbf Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  11. konp Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  12. pkwa Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  13. ktvf Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  14. paga Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  15. khks Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  16. kdsm Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  17. kpsm Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  18. kgrb Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  19. kgmu Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  20. papg Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  1. kbgm Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  2. pamc Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  3. klrd Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  4. ksan Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  5. patk Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  6. kowb Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  7. klru Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  8. kfxe Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  9. kjct Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  10. kcrg Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  11. paaq Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  12. kaex Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  13. klbx Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  14. kmia Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  15. kpit Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  16. kcrw Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  17. paen Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  18. kast Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  19. kuin Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  20. kmht Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  1. krsw Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  2. kbpi Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  3. kcys Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  4. kflo Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  5. kphx Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  6. pakn Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  7. pabt Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  8. krdg Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  9. khdn Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  10. kjac Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  11. cis-acting elements at opposite ends of the Citrus tristeza virus genome differ in initiation and termination of subgenomic RNAs

    International Nuclear Information System (INIS)

    Ayllon, Maria A.; Gowda, Siddarame; Satyanarayana, Tatineni; Dawson, William O.

    2004-01-01

    Citrus tristeza virus (CTV), a member of the Closteroviridae with a plus-stranded genomic RNA of approximately 20 kb, produces 10 3'-coterminal subgenomic (sg) RNAs that serve as messenger (m)RNAs for its internal genes. In addition, a population of 5'-terminal sgRNAs of approximately 700 nts are highly abundant in infected cells. Previous analysis demonstrated that the controller elements (CE) are responsible for the 3'-terminal mRNAs and the small 5'-terminal sgRNAs differ in the number of additional sgRNAs produced. A feature of both types of CE is production of 5'- and 3'-terminal positive-stranded sgRNAs, but the 3' CEs additionally produce a negative-stranded complement of the 3'-terminal mRNAs. Here, we found that the termination (for 5'-terminal sgRNAs) and initiation (for 3'-terminal sgRNAs) sites of the 5' vs. the 3' CEs occur at opposite ends of the respective minimal active CEs. The initiation site for the 3' CE of the major coat protein gene, and probably those of the p20 and p23 genes, was outside (3' in terms of the genomic RNA) the minimal unit, whereas the termination sites were located within the minimal CE, 30-50 nts upstream of the initiation site (referring to the positive-strand sequence). In contrast, the initiation site for the 5' CE was in the 5' region of the minimal unit, with the termination sites 20-35 nts downstream (referring to the positive-strand sequence). Furthermore, the CEs differ in initiation nucleotide and response to mutagenesis of that nucleotide. The 3' CE initiates sgRNA synthesis from a uridylate, whereas the 5' CE initiates from a cytidylate. We previously found that the 3' CEs were unusually tolerant to mutagenesis of the initiation sites, with initiation proceeding from alternative sites. Mutagenesis of the initiation site of the 5' CE prevented synthesis of either the 5'- or 3'-terminal sgRNAs. Thus, the cis-acting elements at opposite ends of the genome are remarkably different, perhaps having arisen from different

  12. Barriers and facilitators to care for the terminally ill: a cross-country case comparison study of Canada, England, Germany, and the United States.

    Science.gov (United States)

    Klinger, Christopher A; Howell, Doris; Zakus, David; Deber, Raisa B

    2014-02-01

    Why do many patients not die at their preferred location? Analyze system-level characteristics influencing the ability to implement best practices in delivering care for terminally ill adults (barriers and facilitators). Cross-country comparison study from a "most similar-most different" perspective, triangulating evidence from a scoping review of the literature, document analyses, and semi-structured key informant interviews. Case study of Canada, England, Germany, and the United States. While similar with regard to leading causes of death, patient needs, and potential avenues to care, different models of service provision were employed in the four countries studied. Although hospice and palliative care services were generally offered with standard care along the disease continuum and in various settings, and featured common elements such as physical, psycho-social, and spiritual care, outcomes (access, utilization, etc.) varied across jurisdictions. Barriers to best practice service provision included legislative (including jurisdictional), regulatory (e.g. education and training), and financial issues as well as public knowledge and perception ("giving up hope") challenges. Advance care planning, dedicated and stable funding toward hospice and palliative care, including caregiver benefits, population aging, and standards of practice and guidelines to hospice and palliative care, were identified as facilitators. Successful implementation of effective and efficient best practice approaches to care for the terminally ill, such as shared care, requires concerted action to align these system-level characteristics; many factors were identified as being essential but not sufficient. Policy implementation needs to be tailored to the respective health-care system(s), monitored, and fine-tuned.

  13. Millist jalga lonkab Eesti demokraatia? / Peet Kask

    Index Scriptorium Estoniae

    Kask, Peet, 1948-

    2010-01-01

    Eesti on ajakirja Economist demokraatiaindeksi järgi postkommunistlike riikide seas 3. kohal. Autor käsitleb küsimusi, mille põhjal indeksi väärtus arvutatakse, ning Eesti saadud tulemusi viies valdkonnas

  14. Family of Advanced Beyond Line-of-Sight Terminals (FAB-T)

    Science.gov (United States)

    2015-12-01

    Selected Acquisition Report (SAR) RCS: DD-A&T(Q&A)823-199 Family of Advanced Beyond Line-of-Sight Terminals ( FAB -T) As of FY 2017 President’s...Budget Defense Acquisition Management Information Retrieval (DAMIR) March 21, 2016 15:24:15 UNCLASSIFIED FAB -T December 2015 SAR March 21, 2016 15:24...Operational Requirements Document OSD - Office of the Secretary of Defense O&S - Operating and Support PAUC - Program Acquisition Unit Cost FAB -T December 2015

  15. MIL-STD-1553 dynamic bus controller/remote terminal hybrid set

    Science.gov (United States)

    Friedman, S. N.

    This paper describes the performance, physical and electrical requirements of a Dual Redundant BUS Interface Unit (BIU) acting as a BUS Controller Interface Unit (BCIU) or Remote Terminal Unit (RTU) between a Motorola 68000 VME BUS and MIL-STD-1553B Multiplex Data Bus. A discussion of how the BIU Hybrid set is programmed, and operates as a BCIU or RTU, will be included. This paper will review Dynamic Bus Control and other Mode Code capabilities. The BIU Hybrid Set interfaces to a 68000 Microprocessor with a VME Bus using programmed I/O transfers. This special interface will be discussed along with the internal Dual Access Memory (4K x 16) used to support the data exchanges between the CPU and the BIU Hybrid Set. The hybrid set's physical size and power requirements will be covered. This includes the present Double Eurocard the BIU function is presently being offered on.

  16. Ports and Terminals : Planning and Functional Design

    NARCIS (Netherlands)

    Groenveld, R.; Velsink, H.

    1993-01-01

    1. Maritime transport, means and commodities 3. Principles of integrated port planning 4. Planning and design of a port's water areas 5. Port terminals - introduction 6. Conventional general cargo terminals 7. Container terminals 8. Oil & liquid gas terminals 9. Dry bulk cargo terminals 10. Fishery

  17. Kajian Kinerja Terminal Batu Ampar Kota Balikpapan

    Directory of Open Access Journals (Sweden)

    Randha Alief Chikita

    2018-01-01

    Full Text Available Batu Ampar Terminal Balikpapan is the only type A passenger terminal in Balikpapan City. The purpose of this study is to determine the operational performance of the terminal at this time and also to determine the level of service in the terminal. The results of this study indicate that for FIFO queue discipline analysis on AKDP and AKAP bus lines, it is known that ρ <1 means that there is currently no queue in the terminal. For the analysis of terminal facilities it is known that there are still some terminal facilities that are not yet available from the main facilities and supporting facilities, therefore the need for additional facilities in order to meet the standard of passenger terminal type A. In the next 15 years analysis for traffic intensity value is approaching 1 which means in the future will cause the queue in the terminal, so it is necessary for the improvement of terminal performance. For the service performance with IPA method there are 35 variables that there are 7 variables that enter in quadrant I. In the next step to do analysis to know the priority of handling by using QFD method. Keywords: Batu Ampar Terminal Balikpapan, IPA, terminal performance, QFD

  18. 25 CFR 11.1114 - Termination.

    Science.gov (United States)

    2010-04-01

    ... Minor-in-Need-of-Care Procedure § 11.1114 Termination. (a) Parental rights to a child may be terminated... rights if, following efforts to prevent or eliminate the need to remove the minor, it finds such efforts... alternatives: (1) If parental rights to a child are terminated, the children's court shall place the minor in a...

  19. St. James marine terminal facility description

    Energy Technology Data Exchange (ETDEWEB)

    1993-10-01

    The US Department of Energy (DOE) currently owns and operates a marine terminal on the west bank of the Mississippi River at St. James, Louisiana. The St. James facility was constructed by the Department to provide marine services associated with the fill and drawdown of the Strategic Petroleum Reserve (SPR) crude oil storage facilities located at Bayou Choctaw and Weeks Island, Louisiana. Although strategic to the mission of the SPR in the event of a national emergency, the St. James terminal is situated such that it has a high potential to also serve the commercial industry`s needs for crude oil terminalling and storage. The St. James terminal is located approximately 45 miles west of New Orleans and 30 miles southeast of Baton Rouge, and approximately 160 miles upstream from the mouth of the Mississippi River. Construction of the St. James terminal was initiated in 1978 and was completed in 1980. Since then, the terminal has received and transferred over 125 million barrels of crude oil to the SPR sites for storage. For crude oil distribution, the St. James terminal was connected to the neighboring LOCAP terminal by a 0.1 mile 36-inch pipeline in 1981 and to the Capline terminal by a 0.5 mile 30-inch pipeline in 1988. The terminal also has a 30-inch pipeline connection to the Koch oil terminal which was used for initial fill purposes; however, this pipeline has been disconnected and is currently inactive. A complete description of the St. James terminal facilities, operational capabilities, operational certifications, and future Government requirements are presented in Sections 2, 3, 4, and 5 respectively.

  20. Incident Command System - Environmental Unit responsibilities

    International Nuclear Information System (INIS)

    Hillman, S. O.

    1997-01-01

    The Incident Command System (ICS) for crisis management, used for response to oil spills by the Alyeska Pipeline Service Company throughout its facilities, including the Trans Alaska Pipeline and the Valdez Marine Terminal, was described. Special attention was given to the Environmental Unit within the ICS which functions as a primary support unit for the Incident Operations Section. Details of the Unit's function were provided. These include the collection, evaluation and dissemination of information on all environmental issues concerning the crisis, provision of advice and direction on environmental aspects, and up-front agency interaction. A checklist of tasks is included. 7 refs

  1. TMS communications software. Volume 2: Bus interface unit

    Science.gov (United States)

    Gregor, P. J.

    1979-01-01

    A data bus communication system to support the space shuttle's Trend Monitoring System (TMS) and to provide a basis for evaluation of the bus concept is described. Installation of the system included developing both hardware and software interfaces between the bus and the specific TMS computers and terminals. The software written for the microprocessor-based bus interface units is described. The software implements both the general bus communications protocol and also the specific interface protocols for the TMS computers and terminals.

  2. Effect of automated ultraviolet C-emitting device on decontamination of hospital rooms with and without real-time observation of terminal room disinfection.

    Science.gov (United States)

    Penno, Katie; Jandarov, Roman A; Sopirala, Madhuri M

    2017-11-01

    We studied the effectiveness of an ultraviolet C (UV-C) emitter in clinical settings and compared it with observed terminal disinfection. We cultured 22 hospital discharge rooms at a tertiary care academic medical center. Phase 1 (unobserved terminal disinfection) included cultures of 11 high-touch environmental surfaces (HTSs) after terminal room disinfection (AD) and after the use of a UV-C-emitting device (AUV). Phase 2 (observed terminal disinfection) included cultures before terminal room disinfection (BD), AD, and AUV. Zero-inflated Poisson regression compared mean colony forming units (CFU) between the groups. Two-sample proportion tests identified significance of the observed differences in proportions of thoroughly cleaned HTSs (CFU cleaning significantly reduced microbial burden and improved the thoroughness of terminal disinfection. We found no further benefit to UV-C use if standard terminal disinfection was observed. Copyright © 2017 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  3. 75 FR 17712 - Malathion and Diquat Dibromide; Cancellation Order for Amendments to Terminate Uses

    Science.gov (United States)

    2010-04-07

    ... Table 1 of Unit II. in a manner inconsistent with any of the Provisions for Disposition of Existing... requested by the registrants and accepted by the Agency, of uses of the products listed in Table 1, pursuant... the registrants listed in Table 2 to voluntarily amend to terminate certain uses of these product...

  4. Aging and the shape of cognitive change before death: terminal decline or terminal drop?

    Science.gov (United States)

    MacDonald, Stuart W S; Hultsch, David F; Dixon, Roger A

    2011-05-01

    Relative to typical age-related cognitive decrements, the terms "terminal decline" and "terminal drop" refer to the phenomenon of increased cognitive decline in proximity to death. Given that these terms are not necessarily synonymous, we examined the important theoretical distinction between the two alternative trajectories or shapes of changes they imply. We used 12-year (5-wave) data from the Victoria Longitudinal Study to directly test whether pre-death cognitive decrements follow a terminal decline (generally gradual) or a terminal drop (more abrupt) shape. Pre-death trajectories of cognitive decline for n=265 decedents (Mage = 72.67 years, SD = 6.44) were examined separately for 5 key cognitive constructs (verbal speed, working memory, episodic memory, semantic memory, and crystallized ability). Several classes of linear mixed models evaluated whether cognitive decline increased per additional year closer to death. Findings indicated that the shape of pre-death cognitive change was predominantly characterized by decline that is steeper as compared with typical aging-related change, but still best described as slow and steady decline, especially as compared with precipitous drop. The present findings suggest that terminal decline and terminal drop trajectories may not be mutually exclusive but could rather reflect distinct developmental trajectories within the same individual.

  5. 42 CFR 489.53 - Termination by CMS.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Termination by CMS. 489.53 Section 489.53 Public... Reinstatement After Termination § 489.53 Termination by CMS. (a) Basis for termination of agreement with any provider. CMS may terminate the agreement with any provider if CMS finds that any of the following failings...

  6. Lazy Productivity via Termination

    NARCIS (Netherlands)

    Endrullis, J.; Hendriks, R.D.A.

    2011-01-01

    We present a procedure for transforming strongly sequential constructor-based term rewriting systems (TRSs) into context-sensitive TRSs in such a way that productivity of the input system is equivalent to termination of the output system. Thereby automated termination provers become available for

  7. Nontraumatic terminal ileal perforation

    Directory of Open Access Journals (Sweden)

    Wani Rauf A

    2006-03-01

    Full Text Available Abstract Background There is still confusion and controversy over the diagnosis and optimal surgical treatment of non traumatic terminal ileal perforation-a cause of obscure peritonitis. Methods This study was a prospective study aimed at evaluating the clinical profile, etiology and optimal surgical management of patients with nontraumatic terminal ileal perforation. Results There were 79 cases of nontraumatic terminal ileal perforation; the causes for perforation were enteric fever(62%, nonspecific inflammation(26%, obstruction(6%, tuberculosis(4% and radiation enteritis (1%. Simple closure of the perforation (49% and end to side ileotransverse anastomosis(42% were the mainstay of the surgical management. Conclusion Terminal ileal perforation should be suspected in all cases of peritonitis especially in developing countries and surgical treatment should be optimized taking various accounts like etiology, delay in surgery and operative findings into consideration to reduce the incidence of deadly complications like fecal fistula.

  8. New chiral liquid crystal with unconventional dioxane terminal unit

    Czech Academy of Sciences Publication Activity Database

    Perkowski, P.; Bubnov, Alexej; Mrukiewicz, M.; Pociecha, D.; Piecek, W.; Hamplová, Věra; Kašpar, Miroslav

    2014-01-01

    Roč. 87, 10-11 (2014), s. 1024-1037 ISSN 0141-1594 R&D Projects: GA MŠk 7AMB13PL041; GA MŠk(CZ) LD14007; GA MŠk(CZ) 7AMB14PL035; GA ČR GA13-14133S Grant - others:AV ČR(CZ) M100101211; AVČR(CZ) M100101204; EU - ICT (XE) COST Action IC1208 Institutional support: RVO:68378271 Keywords : chiral liquid crysta * pentaglyform unit * structural properties * smectic phase * hexagonal ordering * self-assembling Subject RIV: JJ - Other Materials Impact factor: 0.954, year: 2014

  9. The practice of terminal discharge.

    Science.gov (United States)

    Radha Krishna, Lalit Kumar; Murugam, Vengadasalam; Quah, Daniel Song Chiek

    2017-01-01

    'Terminal discharges' are carried out in Singapore for patients who wish to die at home. However, if due diligence is not exercised, parallels may be drawn with euthanasia. We present a theoretical discussion beginning with the definition of terminal discharges and the reasons why they are carried out in Singapore. By considering the intention behind terminal discharges and utilising a multidisciplinary team to deliberate on the clinical, social and ethical intricacies with a patient- and context-specific approach, euthanasia is avoided. It is hoped that this will provide a platform for professionals in palliative medicine to negotiate challenging issues when arranging a terminal discharge, so as to avoid the pitfall of committing euthanasia in a country such as Singapore where euthanasia is illegal. It is hoped that a set of guidelines for terminal discharges may someday be realised to assist professionals in Singapore and around the world.

  10. Exergy Analysis of a Ground-Coupled Heat Pump Heating System with Different Terminals

    Directory of Open Access Journals (Sweden)

    Xiao Chen

    2015-04-01

    Full Text Available In order to evaluate and improve the performance of a ground-coupled heat pump (GCHP heating system with radiant floors as terminals, an exergy analysis based on test results is performed in this study. The system is divided into four subsystems, and the exergy loss and exergy efficiency of each subsystem are calculated using the expressions derived based on exergy balance equations. The average values of the measured parameters are used for the exergy analysis. The analysis results show that the two largest exergy losses occur in the heat pump and terminals, with losses of 55.3% and 22.06%, respectively, and the lowest exergy efficiency occurs in the ground heat exchange system. Therefore, GCHP system designers should pay close attention to the selection of heat pumps and terminals, especially in the design of ground heat exchange systems. Compared with the scenario system in which fan coil units (FCUs are substituted for the radiant floors, the adoption of radiant floors can result in a decrease of 12% in heating load, an increase of 3.24% in exergy efficiency of terminals and an increase of 1.18% in total exergy efficiency of the system. The results may point out the direction and ways of optimizing GCHP systems.

  11. Termination of cycle rewriting

    NARCIS (Netherlands)

    Zantema, H.; König, B.; Bruggink, H.J.S.; Dowek, G.

    2014-01-01

    String rewriting can not only be applied on strings, but also on cycles and even on general graphs. In this paper we investigate termination of string rewriting applied on cycles, shortly denoted as cycle rewriting, which is a strictly stronger requirement than termination on strings. Most

  12. 78 FR 5717 - Safety Zone; Military Ocean Terminal Concord Safety Zone, Suisun Bay, Military Ocean Terminal...

    Science.gov (United States)

    2013-01-28

    ...-AA00 Safety Zone; Military Ocean Terminal Concord Safety Zone, Suisun Bay, Military Ocean Terminal... Guard is establishing a safety zone in the navigable waters of Suisun Bay near Military Ocean Terminal Concord, CA in support of military onload and offload operations. This safety zone is established to...

  13. Rothschildide fond lihtsalt kättesaadav / Romet Kreek

    Index Scriptorium Estoniae

    Kreek, Romet, 1972-

    2008-01-01

    Eesti pankade vahendusel on võimalik liituda Rothschildide pangandusdünastia osalusega RIT Capital Partners fondiga, mille turuväärtus on 1,82 miljardit naela. Diagramm: RIT Capital Partners. Vt. samas: Kui rikas on Rothschildi suguvõsa?

  14. Russo : töötajatel peab lõbus olema / Mariliis Pinn

    Index Scriptorium Estoniae

    Pinn, Mariliis

    2007-01-01

    SAS-i instituudis inimressursside asepresidendina töötanud David Russo esines Baltimaade tegevjuhtide seminaril "Peidetud väärtus" kus ta rääkis, et töötajatest tuleb hoolida ja lasta neid loominguline olla

  15. Amine terminated SAMs: Investigating why oxygen is present in these films

    International Nuclear Information System (INIS)

    Baio, J.E.; Weidner, T.; Brison, J.; Graham, D.J.; Gamble, Lara J.; Castner, David G.

    2009-01-01

    Self-assembled monolayers (SAMs) on gold prepared from amine-terminated alkanethiols have long been employed as model positively charged surfaces. Yet in previous studies significant amounts of unexpected oxygen containing species are always detected in amine terminated SAMs. Thus, the goal of this investigation was to determine the source of these oxygen species and minimize their presence in the SAM. The surface composition, structure, and order of amine-terminated SAMs on Au were characterized by X-ray photoelectron spectroscopy (XPS), time-of-flight secondary ion mass spectroscopy (ToF-SIMS), sum frequency generation (SFG) and near edge X-ray absorption fine structure (NEXAFS) spectroscopy. XPS determined compositions of amine-terminated SAMs in the current study exhibited oxygen concentrations of 2.4 ± 0.4 atomic %, a substantially lower amount of oxygen than reported in previously published studies. High-resolution XPS results from the S 2p , C 1s and N 1s regions did not detect any oxidized species. Angle-resolved XPS indicated that the small amount of oxygen detected was located at or near the amine head group. Small amounts of oxidized nitrogen, carbon and sulfur secondary ions, as well as ions attributed to water, were detected in the ToF-SIMS data due to the higher sensitivity of ToF-SIMS. The lack of N-O, S-O, and C-O stretches in the SFG spectra are consistent with the XPS and ToF-SIMS results and together show that oxidation of the amine-terminated thiols alone can only account for, at most, a small fraction of the oxygen detected by XPS. Both the SFG and angle-dependent NEXAFS indicated the presence of gauche defects in the amine SAMs. However, the SFG spectral features near 2865 cm -1 , assigned to the stretch of the methylene group next to the terminal amine unit, demonstrate the SAM is reasonably ordered. The SFG results also show another broad feature near 3200 cm -1 related to hydrogen-bonded water. From this multi-technique investigation it is

  16. Modelli nullväärtus / Andri Ksenofontov

    Index Scriptorium Estoniae

    Ksenofontov, Andri, 1962-

    2008-01-01

    Toomas Volkmanni näitus "Jeunesse Fatale" galeriis 008 /Rävala 7) kuni 19. VIII. Pikemalt seeriast, mis avaldati raamatus "Brides in Bloom" (lilleseaded: Taivo Piller), inimese ilustamata loomulikkusest

  17. Oil industry consolidation and refined product prices. Evidence from US wholesale gasoline terminals

    International Nuclear Information System (INIS)

    Kendix, Michael; Walls, W.D.

    2010-01-01

    Our objective in this paper is to quantify the impact of petroleum industry consolidation on refined product prices, controlling for other important factors that could also impact prices. Our empirical analysis focuses on the US petroleum refining industry using data on industry consolidation and wholesale gasoline prices collected over the interval 2000-2008. We match refinery units to wholesale city-terminal gasoline markets, and then estimate pooled cross-section time-series regressions to quantify the impact of petroleum industry consolidation on wholesale gasoline prices at city-specific terminals. The results of the empirical analysis of mergers are mixed, showing that some petroleum industry mergers resulted in statistically significant increases in refined product prices; others resulted in statistically significant declines and still others had no statistical impact at all. Our analysis of the effects of measures of market concentration - one at the level of city-specific wholesale terminals and another at the level of regional spot markets - found evidence that less concentrated markets are associated with lower price levels. (author)

  18. Aare Sosaar nõuab sisse ERA Panga halbu laene / Tiit Elner

    Index Scriptorium Estoniae

    Elner, Tiit

    2000-01-01

    Ekspankur Aare Sosaare juhitav teadmata omanikega ERA Liising ostis pankrotis ERA Pangalt probleemseid laene, suurem nõuete ostja oli ka Krediidipank. Kokku on müüdud laenude lepingujärgne väärtus kuni 100 mln. kr.

  19. "Klassivaenlase poolt on organiseeritud rida mitmesuguseid nõukogude vastaseid väljendusi..." / Tiit Noormets

    Index Scriptorium Estoniae

    Noormets, Tiit, 1959-

    2016-01-01

    Parteiinformatsioonid olid mitmekesise sisuga. Eri aegadel ja maakondades koostatud informatsioonid olid erineva väärtusega. Suurem väärtus on informatsioonides jäädvustatud värvikates seikades ja ütlustes, mis aitavad meie ajaloopilti elavadada

  20. NASA work unit system file maintenance manual

    Science.gov (United States)

    1972-01-01

    The NASA Work Unit System is a management information system for research tasks (i.e., work units) performed under NASA grants and contracts. It supplies profiles on research efforts and statistics on fund distribution. The file maintenance operator can add, delete and change records at a remote terminal or can submit punched cards to the computer room for batch update. The system is designed for file maintenance by a person with little or no knowledge of data processing techniques.

  1. Mobile Termination and Mobile Penetration

    OpenAIRE

    Hurkens, Sjaak; Jeon, Doh-Shin

    2009-01-01

    In this paper, we study how access pricing affects network competition when subscription demand is elastic and each network uses non-linear prices and can apply termination-based price discrimination. In the case of a fixed per minute termination charge, we find that a reduction of the termination charge below cost has two oppos- ing effects: it softens competition but helps to internalize network externalities. The former reduces mobile penetration while the latter boosts it. We find that fi...

  2. Mobile termination and mobile penetration

    OpenAIRE

    Hurkens, Sjaak

    2009-01-01

    In this paper, we study how access pricing affects network competition when subscription demand is elastic and each network uses non-linear prices and can apply termination-based price discrimination. In the case of a fixed per minute termination charge, we find that a reduction of the termination charge below cost has two opposing effects: it softens competition but helps to internalize network externalities. The former reduces mobile penetration while the latter boosts it. We find that firm...

  3. 49 CFR 374.309 - Terminal facilities.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 5 2010-10-01 2010-10-01 false Terminal facilities. 374.309 Section 374.309... REGULATIONS Adequacy of Intercity Motor Common Carrier Passenger Service § 374.309 Terminal facilities. (a... attendants and be regularly patrolled. (b) Outside facilities. At terminals and stations that are closed when...

  4. Prematurely terminated slug tests

    International Nuclear Information System (INIS)

    Karasaki, K.

    1990-07-01

    A solution of the well response to a prematurely terminated slug test (PTST) is presented. The advantages of a PTST over conventional slug tests are discussed. A systematized procedure of a PTST is proposed, where a slug test is terminated in the midpoint of the flow point, and the subsequent shut-in data is recorded and analyzed. This method requires a downhole shut-in device and a pressure transducer, which is no more than the conventional deep-well slug testing. As opposed to slug tests, which are ineffective when a skin is present, more accurate estimate of formation permeability can be made using a PTST. Premature termination also shortens the test duration considerably. Because in most cases no more information is gained by completing a slug test to the end, the author recommends that conventional slug tests be replaced by the premature termination technique. This study is part of an investigation of the feasibility of geologic isolation of nuclear wastes being carried out by the US Department of Energy and the National Cooperative for the Storage of Radioactive Waste of Switzerland

  5. 9 CFR 3.91 - Terminal facilities.

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Terminal facilities. 3.91 Section 3.91... Primates 2 Transportation Standards § 3.91 Terminal facilities. (a) Placement. Any persons subject to the... with inanimate cargo or with other animals in animal holding areas of terminal facilities. Nonhuman...

  6. 9 CFR 3.18 - Terminal facilities.

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Terminal facilities. 3.18 Section 3.18... Cats 1 Transportation Standards § 3.18 Terminal facilities. (a) Placement. Any person subject to the... inanimate cargo in animal holding areas of terminal facilities. (b) Cleaning, sanitization, and pest control...

  7. 75 FR 2159 - In the Matter of Certain Variable Speed Wind Turbines and Components Thereof; Termination of...

    Science.gov (United States)

    2010-01-14

    ... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-641] In the Matter of Certain Variable Speed Wind Turbines and Components Thereof; Termination of Investigation With Final Determination of No..., and the sale within the United States after importation of certain variable speed wind turbines and...

  8. 7 CFR 1469.25 - Contract violations and termination.

    Science.gov (United States)

    2010-01-01

    ... termination without delay. (c) If NRCS terminates a contract due to breach of contract, the participant will... terminates a contract due to breach of contract, or the participant voluntarily terminates the contract... 7 Agriculture 10 2010-01-01 2010-01-01 false Contract violations and termination. 1469.25 Section...

  9. Compact Termination for Structural Soft-goods

    Science.gov (United States)

    Wilkes, Robert, Jr.

    2013-01-01

    Glass fiber is unique in its ability to withstand atomic oxygen and ultraviolet radiation in-space environments. However, glass fiber is also difficult to terminate by traditional methods without decreasing its strength significantly. Glass fiber products are especially sensitive to bend radius, and do not work very well with traditional 'sewn loop on pin' type connections. As with most composites, getting applied loads from a metallic structure into the webbing without stress concentrations is the key to a successful design. A potted end termination has been shown in some preliminary work to out-perform traditional termination methods. It was proposed to conduct a series of tensile tests on structural webbing or cord to determine the optimum potting geometry, and to then be able to estimate a weight and volume savings over traditional sewn-overa- pin connections. During the course of the investigation into potted end terminations for glass fiber webbing, a new and innovative connection was developed that has lower weight, reduced fabrication time, and superior thermal tolerance over the metallic end terminations that were to be optimized in the original proposal. This end termination essentially transitions the flexible glass fiber webbing into a rigid fiberglass termination, which can be bolted/fastened with traditional methods

  10. 9 CFR 3.40 - Terminal facilities.

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Terminal facilities. 3.40 Section 3.40... Pigs and Hamsters Transportation Standards § 3.40 Terminal facilities. No person subject to the Animal... animal holding areas of a terminal facility where shipments of live guinea pigs or hamsters are...

  11. 9 CFR 3.65 - Terminal facilities.

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Terminal facilities. 3.65 Section 3.65... Transportation Standards § 3.65 Terminal facilities. No person subject to the Animal Welfare regulations shall commingle shipments of live rabbits with inanimate cargo. All animal holding areas of a terminal facility...

  12. An Intelligent Terminal for Access to a Medical Database

    Science.gov (United States)

    Womble, M. E.; Wilson, S. D.; Keiser, H. N.; Tworek, M. L.

    1978-01-01

    Very powerful data base management systems (DBMS) now exist which allow medical personnel access to patient record data bases. DBMS's make it easy to retrieve either complete or abbreviated records of patients with similar characteristics. In addition, statistics on data base records are immediately accessible. However, the price of this power is a large computer with the inherent problems of access, response time, and reliability. If a general purpose, time-shared computer is used to get this power, the response time to a request can be either rapid or slow, depending upon loading by other users. Furthermore, if the computer is accessed via dial-up telephone lines, there is competition with other users for telephone ports. If either the DBMS or the host machine is replaced, the medical users, who are typically not sophisticated in computer usage, are forced to learn the new system. Microcomputers, because of their low cost and adaptability, lend themselves to a solution of these problems. A microprocessor-based intelligent terminal has been designed and implemented at the USAF School of Aerospace Medicine to provide a transparent interface between the user and his data base. The intelligent terminal system includes multiple microprocessors, floppy disks, a CRT terminal, and a printer. Users interact with the system at the CRT terminal using menu selection (framing). The system translates the menu selection into the query language of the DBMS and handles all actual communication with the DBMS and its host computer, including telephone dialing and sign on procedures, as well as the actual data base query and response. Retrieved information is stored locally for CRT display, hard copy production, and/or permanent retention. Microprocessor-based communication units provide security for sensitive medical data through encryption/decryption algorithms and high reliability error detection transmission schemes. Highly modular software design permits adapation to a

  13. N-terminal-pro-B-type natriuretic peptide during pharmacological heart rate reduction in hyperthyroidism

    DEFF Research Database (Denmark)

    Schultz, M; Kistorp, C; Corell, P

    2009-01-01

    days. Before treatment, N-terminal-pro-B-type natriuretic peptide was independently associated with thyroid function (free triiodothyronine-index, r=0.64, p=0.001) and the hemoglobin concentration (r=-0.36, p=0.031). The verapamil treatment induced a decrease in parameters reflecting cardiac function......-index decreased from median 319 to 315 arbitrary units (p=0.039) and free triiodothyronine-index increased from 8.6 to 9.9 arbitrary units (p=0.010). No changes in echocardiographic parameters were observed. A decrease in resting heart rate in untreated hyperthyroidism due to verapamil treatment did not result...

  14. Battery system including batteries that have a plurality of positive terminals and a plurality of negative terminals

    Science.gov (United States)

    Dougherty, Thomas J; Symanski, James S; Kuempers, Joerg A; Miles, Ronald C; Hansen, Scott A; Smith, Nels R; Taghikhani, Majid; Mrotek, Edward N; Andrew, Michael G

    2014-01-21

    A lithium battery for use in a vehicle includes a container, a plurality of positive terminals extending from a first end of the lithium battery, and a plurality of negative terminals extending from a second end of the lithium battery. The plurality of positive terminals are provided in a first configuration and the plurality of negative terminals are provided in a second configuration, the first configuration differing from the second configuration. A battery system for use in a vehicle may include a plurality of electrically connected lithium cells or batteries.

  15. Termination of plastic-clad fiber

    International Nuclear Information System (INIS)

    Nance, W.R.

    1982-03-01

    Optical waveguides are ideal in a nuclear weapon environment because of their resistance to electromagnetic interference. Of the fibers on today's market, plastic-clad silica (PCS) is the most radiation resistant and therfore the best choice. Because terminating PCS is complex, this paper attemps to address the major problems associated with these terminations including selecting the proper connector and optimizing the terminating procedures. The sources of losses in the connectors are summarized and typical loss values are given for four connectors which were tested

  16. Effect of Ge surface termination on oxidation behavior

    Science.gov (United States)

    Lee, Younghwan; Park, Kibyung; Cho, Yong Soo; Lim, Sangwoo

    2008-09-01

    Sulfur-termination was formed on the Ge(1 0 0) surface using (NH 4) 2S solution. Formation of Ge-S and the oxidation of the S-terminated Ge surface were monitored with multiple internal reflection Fourier transform infrared spectroscopy and X-ray photoelectron spectroscopy. In the 0.5, 5, or 20% (NH 4) 2S solution, H-termination on the Ge(1 0 0) surface was substituted with S-termination in 1 min. When the S-terminated Ge(1 0 0) surface was exposed in air ambient, the oxidation was retarded for about 3600 min. The preservation time of the oxide layer up to one monolayer of S-terminated Ge(1 0 0) surface was about 120 times longer than for the H-terminated Ge(1 0 0) surface. However, the oxidation of S-terminated Ge(1 0 0) surface drastically increased after the threshold time. There was no significant difference in threshold time between S-terminations formed in 0.5, 5, and 20% (NH 4) 2S solutions. With the surface oxidation, desorption of S on the Ge surface was observed. The desorption behavior of sulfur on the S-terminated Ge(1 0 0) surface was independent of the concentration of the (NH 4) 2S solution that forms S-termination. Non-ideal S-termination on Ge surfaces may be related to drastic oxidation of the Ge surface. Finally, with the desulfurization on the S-terminated Ge(1 0 0) surface, oxide growth is accelerated.

  17. Visual operations management tools in oil pipelines and terminals standardization processes

    Energy Technology Data Exchange (ETDEWEB)

    De Ludovico Almeida, Maria Fatima [Pontifical Catholic University of Rio de Janeiro (Brazil); Santiago, Adilson; Senra Ribeiro, Kassandra; Mendonca Arruda, Daniela [Petrobras Transporte (Brazil)

    2010-07-01

    Visual operations management (VOM) takes advantage of visual cues to communicate information, simplify processes and improve the quality and safety of operations. Because of heightened competition, the importance of standardization and quality management processes has become more evident for pipeline companies. Petrobras Transporte's marine terminal units has been working over the last years to be recognized as a reference in the activities it pursues. This is based on the Petrobras Transporte's strategic plan 2020, which foresees amongst others, the specialization of technical workforce, operational safety excellence, capital discipline, customer satisfaction, the search for new technologies and markets and the rendering of new services. To achieve these goals, the Marine Terminals standardization program must be adhered to. Focusing on communication and adoption of standards and procedures, this paper describes how visual guides were conceived and implemented within Petrobras Transporte to enable operators and technicians to meet operational, environmental and occupational health and safety requirements.

  18. 12 innovatsioonivõimalust ettevõtetele / Mohanbir Sawhney, Robert C. Wolcott, Inigo Arroniz

    Index Scriptorium Estoniae

    Sawhney, Mohanbir

    2006-01-01

    Artiklis tutvustatakse ettevõtteinnovatsiooni kui käsitlust, mille kohaselt on innovatsioonil mõte ainult siis, kui sellest tekib lisaväärtus klientidele. Samas tutvustatakse ka äriinnovatsiooni 12 mõõdet, mis moodustavad innovatsiooniradari. Lisa: Innovatsiooniradar; Konkurentide võrdlemine innovatsiooniradaril

  19. Ameerika mäed pensioniraha näitel / Villu Zirnask

    Index Scriptorium Estoniae

    Zirnask, Villu, 1966-

    2011-01-01

    2010. aasta lõpuks oli kohustuslike pensionifondide vara väärtus taas tõusnud kõrgemale sissemaksete mahust. Keskmiselt on fondide reaaltootlus olnud negatiivne. USA börsianalüütiku Ed Eastelingi raamatust "Tõenäolised tulemused: aktsiaturu pikaajalised perspektiivid". Diagrammid

  20. Mechanisms of DNA replication termination.

    Science.gov (United States)

    Dewar, James M; Walter, Johannes C

    2017-08-01

    Genome duplication is carried out by pairs of replication forks that assemble at origins of replication and then move in opposite directions. DNA replication ends when converging replication forks meet. During this process, which is known as replication termination, DNA synthesis is completed, the replication machinery is disassembled and daughter molecules are resolved. In this Review, we outline the steps that are likely to be common to replication termination in most organisms, namely, fork convergence, synthesis completion, replisome disassembly and decatenation. We briefly review the mechanism of termination in the bacterium Escherichia coli and in simian virus 40 (SV40) and also focus on recent advances in eukaryotic replication termination. In particular, we discuss the recently discovered E3 ubiquitin ligases that control replisome disassembly in yeast and higher eukaryotes, and how their activity is regulated to avoid genome instability.

  1. Unit Monitors Manchester-Format Data Buses

    Science.gov (United States)

    Amador, Jose J.

    1994-01-01

    Circuit card converts data signals into convenient hexadecimal form for troubleshooting. Bus-monitoring unit converts data signals from Manchester II format used on data bus into hexadecimal format. Monitoring circuit causes hexadecimal words to display on video terminal, where test engineer compares them with hexadecimal records for troubleshooting. Circuit monitors one bus or two buses simultaneously.

  2. Crystallization of the C-terminal domain of the mouse brain cytosolic long-chain acyl-CoA thioesterase

    International Nuclear Information System (INIS)

    Serek, Robert; Forwood, Jade K.; Hume, David A.; Martin, Jennifer L.; Kobe, Bostjan

    2006-01-01

    The C-terminal domain of the mouse long-chain acyl-CoA thioesterase has been expressed in bacteria and crystallized by vapour diffusion. The crystals diffract to 2.4 Å resolution. The mammalian long-chain acyl-CoA thioesterase, the enzyme that catalyses the hydrolysis of acyl-CoAs to free fatty acids, contains two fused 4HBT (4-hydroxybenzoyl-CoA thioesterase) motifs. The C-terminal domain of the mouse long-chain acyl-CoA thioesterase (Acot7) has been expressed in bacteria and crystallized. The crystals were obtained by vapour diffusion using PEG 2000 MME as precipitant at pH 7.0 and 290 K. The crystals have the symmetry of space group R32 (unit-cell parameters a = b = 136.83, c = 99.82 Å, γ = 120°). Two molecules are expected in the asymmetric unit. The crystals diffract to 2.4 Å resolution using the laboratory X-ray source and are suitable for crystal structure determination

  3. Chemical Shift Assignments of the C-terminal Eps15 Homology Domain-3 EH Domain*

    Science.gov (United States)

    Caplan, Steve; Sorgen, Paul L.

    2013-01-01

    The C-terminal Eps15 homology (EH) domain 3 (EHD3) belongs to a eukaryotic family of endocytic regulatory proteins and is involved in the recycling of various receptors from the early endosome to the endocytic recycling compartment or in retrograde transport from the endosomes to the Golgi. EH domains are highly conserved in the EHD family and function as protein-protein interaction units that bind to Asn-Pro-Phe (NPF) motif-containing proteins. The EH domain of EHD1 was the first C-terminal EH domain from the EHD family to be solved by NMR. The differences observed between this domain and proteins with N-terminal EH domains helped describe a mechanism for the differential binding of NPF-containing proteins. Here, structural studies were expanded to include the EHD3 EH domain. While the EHD1 and EHD3 EH domains are highly homologous, they have different protein partners. A comparison of these structures will help determine the selectivity in protein binding between the EHD family members and lead to a better understanding of their unique roles in endocytic regulation. PMID:23754701

  4. Differential isotope dansylation labeling combined with liquid chromatography mass spectrometry for quantification of intact and N-terminal truncated proteins

    International Nuclear Information System (INIS)

    Tang, Yanan; Li, Liang

    2013-01-01

    Graphical abstract: -- Highlights: •LC–MS was developed for quantifying protein mixtures containing both intact and N-terminal truncated proteins. • 12 C 2 -Dansylation of the N-terminal amino acid of proteins was done first, followed by microwave-assisted acid hydrolysis. •The released 12 C 2 -dansyl labeled N-terminal amino acid was quantified using 13 C 2 -dansyl labeled amino acid standards. •The method provided accurate and precise results for quantifying intact and N-terminal truncated proteins within 8 h. -- Abstract: The N-terminal amino acids of proteins are important structure units for maintaining the biological function, localization, and interaction networks of proteins. Under different biological conditions, one or several N-terminal amino acids could be cleaved from an intact protein due to processes, such as proteolysis, resulting in the change of protein properties. Thus, the ability to quantify the N-terminal truncated forms of proteins is of great importance, particularly in the area of development and production of protein-based drugs where the relative quantity of the intact protein and its truncated form needs to be monitored. In this work, we describe a rapid method for absolute quantification of protein mixtures containing intact and N-terminal truncated proteins. This method is based on dansylation labeling of the N-terminal amino acids of proteins, followed by microwave-assisted acid hydrolysis of the proteins into amino acids. It is shown that dansyl labeled amino acids are stable in acidic conditions and can be quantified by liquid chromatography mass spectrometry (LC–MS) with the use of isotope analog standards

  5. What is a "good enough" termination?

    Science.gov (United States)

    Gabbard, Glen O

    2009-06-01

    In Freud's technique papers, he failed to develop a systematic approach to termination. Much of the existing literature is based on psychoanalytic mythologies about the way patients are expected to end analysis. The models described in the literature are often starkly at odds with what one sees in clinical practice. A wish for idealized versions of termination underlies much of what has been written, and we need to shift to a conceptual model involving "good enough" termination. A number of different endings to psychoanalysis may, in the long run, lead to productive outcomes; these models are examined, as are various approaches to the dilemmas presented at the time of termination.

  6. Trauma and termination.

    Science.gov (United States)

    Ferraro, F

    1995-02-01

    The author suggests a particular reading of the thesis put forward by Freud in 'Analysis terminable and interminable' that an effective and more definitive conclusion may be expected in analyses of cases with traumatic aetiology. This reading shifts the emphasis from the patient's history to the possibility of its crystallising in focal nuclei emerging within the analytic relationship under the pressure of the termination. The revival of separation anxieties which cannot be worked through, and their crystallisation in precipitating traumatic events, may give rise to decisive psychic work allowing the analysis to be brought to a conclusion. Two case histories are presented to show how the end of the analysis assumes the form of a new trauma, which reactivates in the present, traumatic anxieties from the patient's own infantile history. In the first case a premature birth and in the second a miscarriage, originally experienced as isolated automatic events without time or history, are relived in the terminal phase as vicissitudes of the transference, so that new meaning can be assigned to them and they can be withdrawn from the somatic cycle of repetition. The powerful tendency to act out and the intense countertransference pressure on the analyst are discussed in the light of the specificities of this phase, which is crucial to the success of the analysis. This leads to a re-examination, in the concluding notes, of some theoretical questions inherent in the problem of the termination and, in particular, to a discussion of the ambiguous concept of a natural ending.

  7. Minimum airflow reset of single-duct VAV terminal boxes

    Science.gov (United States)

    Cho, Young-Hum

    Single duct Variable Air Volume (VAV) systems are currently the most widely used type of HVAC system in the United States. When installing such a system, it is critical to determine the minimum airflow set point of the terminal box, as an optimally selected set point will improve the level of thermal comfort and indoor air quality (IAQ) while at the same time lower overall energy costs. In principle, this minimum rate should be calculated according to the minimum ventilation requirement based on ASHRAE standard 62.1 and maximum heating load of the zone. Several factors must be carefully considered when calculating this minimum rate. Terminal boxes with conventional control sequences may result in occupant discomfort and energy waste. If the minimum rate of airflow is set too high, the AHUs will consume excess fan power, and the terminal boxes may cause significant simultaneous room heating and cooling. At the same time, a rate that is too low will result in poor air circulation and indoor air quality in the air-conditioned space. Currently, many scholars are investigating how to change the algorithm of the advanced VAV terminal box controller without retrofitting. Some of these controllers have been found to effectively improve thermal comfort, indoor air quality, and energy efficiency. However, minimum airflow set points have not yet been identified, nor has controller performance been verified in confirmed studies. In this study, control algorithms were developed that automatically identify and reset terminal box minimum airflow set points, thereby improving indoor air quality and thermal comfort levels, and reducing the overall rate of energy consumption. A theoretical analysis of the optimal minimum airflow and discharge air temperature was performed to identify the potential energy benefits of resetting the terminal box minimum airflow set points. Applicable control algorithms for calculating the ideal values for the minimum airflow reset were developed and

  8. N-Terminal Domains in Two-Domain Proteins Are Biased to Be Shorter and Predicted to Fold Faster Than Their C-Terminal Counterparts

    Directory of Open Access Journals (Sweden)

    Etai Jacob

    2013-04-01

    Full Text Available Computational analysis of proteomes in all kingdoms of life reveals a strong tendency for N-terminal domains in two-domain proteins to have shorter sequences than their neighboring C-terminal domains. Given that folding rates are affected by chain length, we asked whether the tendency for N-terminal domains to be shorter than their neighboring C-terminal domains reflects selection for faster-folding N-terminal domains. Calculations of absolute contact order, another predictor of folding rate, provide additional evidence that N-terminal domains tend to fold faster than their neighboring C-terminal domains. A possible explanation for this bias, which is more pronounced in prokaryotes than in eukaryotes, is that faster folding of N-terminal domains reduces the risk for protein aggregation during folding by preventing formation of nonnative interdomain interactions. This explanation is supported by our finding that two-domain proteins with a shorter N-terminal domain are much more abundant than those with a shorter C-terminal domain.

  9. Efficiency analysis of container ports and terminals

    OpenAIRE

    Liu, Q.

    2010-01-01

    In the past two decades the steady growth of seaborne trade has resulted in the increase of container ships, container ports and their terminals. The structure of the shipping market is, moreover, continuously evolving. On the carrier side, shipping companies form consortia and alliances; on the port side, global terminal operators and dedicated container terminals are emerging. The aim of this research is to evaluate the efficiency of container ports and terminals and to study...

  10. Strategic technology alliance termination : an empirical investigation

    NARCIS (Netherlands)

    Sadowski, B.M.; Duysters, G.M.

    2008-01-01

    There is growing consensus that overall alliance termination rates are high. However, despite this track record of termination and despite unsurpassed growth rates of strategic technology alliances, little is known about the reasons for their termination. Typically strategic alliances have been

  11. Modified Current Differencing Unit and its Application for Electronically Reconfigurable Simple First-order Transfer Function

    Directory of Open Access Journals (Sweden)

    SOTNER, R.

    2015-02-01

    Full Text Available Modified current differencing unit (MCDU and its simple filtering application are introduced in this paper. Modification of the well-known current differencing unit consists in weighted difference of both input currents controlled by adjustable current gain, controllable intrinsic resistance of both current input terminals, and availability of additional voltage terminal(s. Definition of MCDU therefore requires four adjustable parameters (B1, B2, Rp, Rn. A presented active element offers and combines benefits of electronically controllable current conveyor of second generation and current differencing unit and allows synthesis of interesting adjustable applications, which are not available by classical approaches based on simple elements. MCDU brings variability of the transfer function into the structure. It provides several transfer types without necessity of input or output node change by simple electronic tuning. A presented structure represents so-called reconnection-less reconfigurable current-mode filter for realization of all-pass, inverting high-pass, low-pass and direct transfer response. Behavioral model of the MCDU was prepared and carefully tested in filtering application. Spice simulations and measurements confirmed theoretical assumptions.

  12. Click functionalization of phenyl-capped bithiophene on azide-terminated self-assembled monolayers

    International Nuclear Information System (INIS)

    Zheng, Yijun; Cui, Jiaxi; Ikeda, Taichi

    2015-01-01

    Graphical abstract: - Highlights: • Electrochemically-active self-assembled monolayers with phenyl-capped bithiophene were prepared. • Post-functionalization method based on click chemistry solved the solubility issue of phenyl-capped thiophene alkanethiol. • The capture and release of the counter anions during the redox reaction were detectable by E-QCM. - Abstract: We immobilized tetra(ethylene glycol)-substituted phenyl-capped bithiophene with alkyne terminals (Ph2TPh-alkyne) on azide-terminated self-assembled monolayers (N 3 -SAMs) by Cu-catalyzed azide-alkyne cycloaddition reaction. Ph2TPh-functionalized SAMs on a gold substrate showed reversible electrochemical response. The surface densities of the azide groups in N 3 -SAMs and Ph2TPh units in Ph2TPh-functionalized SAMs were estimated to be 7.3 ± 0.3 × 10 −10 mol cm −2 and 4.6 ± 0.3 × 10 −10 mol cm −2 , respectively, by quartz crystal microbalance (QCM). Most of Ph2TPh-alkynes are considered to be anchored on N 3 -SAMs via both terminal groups. Ph2TPh-functionalized SAMs exhibited reversible redox peaks in cyclic voltammetry (CV). In redox reaction, reversible capture and release of the counter anion could be monitored by electrochemical QCM (E-QCM).

  13. Click functionalization of phenyl-capped bithiophene on azide-terminated self-assembled monolayers

    Energy Technology Data Exchange (ETDEWEB)

    Zheng, Yijun; Cui, Jiaxi [Max Planck Institute for Polymer Research (MPIP), Ackermannweg 10, Mainz 55128 (Germany); Ikeda, Taichi, E-mail: IKEDA.Taichi@nims.go.jp [Max Planck Institute for Polymer Research (MPIP), Ackermannweg 10, Mainz 55128 (Germany); Polymer Materials Unit, National Institute for Materials Science (NIMS), 1-1 Namiki, Tsukuba 305-0044 (Japan)

    2015-11-15

    Graphical abstract: - Highlights: • Electrochemically-active self-assembled monolayers with phenyl-capped bithiophene were prepared. • Post-functionalization method based on click chemistry solved the solubility issue of phenyl-capped thiophene alkanethiol. • The capture and release of the counter anions during the redox reaction were detectable by E-QCM. - Abstract: We immobilized tetra(ethylene glycol)-substituted phenyl-capped bithiophene with alkyne terminals (Ph2TPh-alkyne) on azide-terminated self-assembled monolayers (N{sub 3}-SAMs) by Cu-catalyzed azide-alkyne cycloaddition reaction. Ph2TPh-functionalized SAMs on a gold substrate showed reversible electrochemical response. The surface densities of the azide groups in N{sub 3}-SAMs and Ph2TPh units in Ph2TPh-functionalized SAMs were estimated to be 7.3 ± 0.3 × 10{sup −10} mol cm{sup −2} and 4.6 ± 0.3 × 10{sup −10} mol cm{sup −2}, respectively, by quartz crystal microbalance (QCM). Most of Ph2TPh-alkynes are considered to be anchored on N{sub 3}-SAMs via both terminal groups. Ph2TPh-functionalized SAMs exhibited reversible redox peaks in cyclic voltammetry (CV). In redox reaction, reversible capture and release of the counter anion could be monitored by electrochemical QCM (E-QCM).

  14. 24 CFR 983.207 - Condition of contract units.

    Science.gov (United States)

    2010-04-01

    ... URBAN DEVELOPMENT PROJECT-BASED VOUCHER (PBV) PROGRAM Housing Assistance Payments Contract § 983.207... in accordance with the HQS. The PHA may not make any HAP payment to the owner for a contract unit.... Such remedies include termination of housing assistance payments, abatement or reduction of housing...

  15. Laidoneri-Savisaare villa hinnati juba 2003. aastal 800 000 kroonile / Martti Kass

    Index Scriptorium Estoniae

    Kass, Martti

    2005-01-01

    Edgar Savisaare firma ostetud suvila Keila-Joal oli 2003. aastal Arco Vara hinnangul väärt 800 000 krooni. Kinnisvaraekspertide hinnangul on Keila-Joa kinnisvara väärtus viimaste aastatega mitu korda suurenenud. Lisa: Ojulandi ja Käo maja hinnati 3,25 miljonile

  16. Madal palk ei ole konkurentsieelis / Kristo Kiviorg

    Index Scriptorium Estoniae

    Kiviorg, Kristo

    2007-01-01

    Seminaril "Peidetud väärtus: kuidas ettevõtted saavutavad tavaliste inimeste abiga erakordseid tulemusi" ettekannetega esinenud Stanfordi Ülikooli professor Jeffrey Pfeffer ning inimressursside juhtimise konsultant David Russo tõdesid, et madal palk ei taga firmadele konkurentsieelist, kuigi paljud juhid nõnda arvavad

  17. Relationship between organisational culture and individual values of the Russian-speaking members of an organisation in Lithuania / Elina Tolmats

    Index Scriptorium Estoniae

    Tolmats, Elina

    2003-01-01

    Uurimuse tulemused näitasid, et madalamaid hinnanguid organisatsioonikultuuri ülesande orientatsioonile annavad organisatsiooni need liikmed, kes väärtustavad kõrgelt ümbritsevat ilu, kõrgemaid hinnanguid aga need, kelle jaoks on oluline tugiväärtus edasipüüdlik. Tabelid

  18. Terminal addition in a cellular world.

    Science.gov (United States)

    Torday, J S; Miller, William B

    2018-07-01

    Recent advances in our understanding of evolutionary development permit a reframed appraisal of Terminal Addition as a continuous historical process of cellular-environmental complementarity. Within this frame of reference, evolutionary terminal additions can be identified as environmental induction of episodic adjustments to cell-cell signaling patterns that yield the cellular-molecular pathways that lead to differing developmental forms. Phenotypes derive, thereby, through cellular mutualistic/competitive niche constructions in reciprocating responsiveness to environmental stresses and epigenetic impacts. In such terms, Terminal Addition flows according to a logic of cellular needs confronting environmental challenges over space-time. A reconciliation of evolutionary development and Terminal Addition can be achieved through a combined focus on cell-cell signaling, molecular phylogenies and a broader understanding of epigenetic phenomena among eukaryotic organisms. When understood in this manner, Terminal Addition has an important role in evolutionary development, and chronic disease might be considered as a form of 'reverse evolution' of the self-same processes. Copyright © 2017. Published by Elsevier Ltd.

  19. Concept Layout Model of Transportation Terminals

    OpenAIRE

    Yao, Li-ya; Sun, Li-shan; Wang, Wu-hong; Xiong, Hui

    2012-01-01

    Transportation terminal is the key node in transport systems. Efficient terminals can improve operation of passenger transportation networks, adjust the layout of public transportation networks, provide a passenger guidance system, and regulate the development of commercial forms, as well as optimize the assembly and distribution of modern logistic modes, among others. This study aims to clarify the relationship between the function and the structure of transportation terminals and establish ...

  20. 14 CFR 272.12 - Termination.

    Science.gov (United States)

    2010-01-01

    ... Aeronautics and Space OFFICE OF THE SECRETARY, DEPARTMENT OF TRANSPORTATION (AVIATION PROCEEDINGS) ECONOMIC REGULATIONS ESSENTIAL AIR SERVICE TO THE FREELY ASSOCIATED STATES § 272.12 Termination. These provisions shall terminate on October 1, 1998, unless the program of essential air service to the Federated States of...

  1. Terminal structure

    Science.gov (United States)

    Schmidt, Frank [Langenhagen, DE; Allais, Arnaud [Hannover, DE; Mirebeau, Pierre [Villebon sur Yvette, FR; Ganhungu, Francois [Vieux-Reng, FR; Lallouet, Nicolas [Saint Martin Boulogne, FR

    2009-10-20

    A terminal structure (2) for a superconducting cable (1) is described. It consists of a conductor (2a) and an insulator (2b) that surrounds the conductor (2a), wherein the superconducting cable (1) has a core with a superconducting conductor (5) and a layer of insulation that surrounds the conductor (5), and wherein the core is arranged in such a way that it can move longitudinally in a cryostat. The conductor (2a) of the terminal structure (2) is electrically connected with the superconducting conductor (5) or with a normal conductor (6) that is connected with the superconducting conductor (5) by means of a tubular part (7) made of an electrically conductive material, wherein the superconducting conductor (5) or the normal conductor (6) can slide in the part (7) in the direction of the superconductor.

  2. 43 CFR 29.13 - Termination.

    Science.gov (United States)

    2010-10-01

    ... Termination. Upon termination of operations of the Pipeline, the full disposition of all claims, and the... shall request that Congress provide for final disposition of the Fund. If Congress at any time establishes a comprehensive oil pollution liability fund which supersedes or repeals the Fund, the Fund assets...

  3. 7 CFR 983.89 - Termination.

    Science.gov (United States)

    2010-01-01

    ..., ARIZONA, AND NEW MEXICO Miscellaneous Provisions § 983.89 Termination. (a) The Secretary may at any time..., That such majority has, during such representative period, produced for market more than fifty percent of the volume of such pistachios produced for market, but such termination shall be announced at...

  4. 49 CFR 450.15 - Termination of delegation.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 6 2010-10-01 2010-10-01 false Termination of delegation. 450.15 Section 450.15... SECURITY SAFETY APPROVAL OF CARGO CONTAINERS GENERAL Procedure for Delegation to Approval Authorities § 450.15 Termination of delegation. (a) An Approval Authority may voluntarily terminate its delegation by...

  5. Differential isotope dansylation labeling combined with liquid chromatography mass spectrometry for quantification of intact and N-terminal truncated proteins

    Energy Technology Data Exchange (ETDEWEB)

    Tang, Yanan; Li, Liang, E-mail: Liang.Li@ualberta.ca

    2013-08-20

    Graphical abstract: -- Highlights: •LC–MS was developed for quantifying protein mixtures containing both intact and N-terminal truncated proteins. •{sup 12}C{sub 2}-Dansylation of the N-terminal amino acid of proteins was done first, followed by microwave-assisted acid hydrolysis. •The released {sup 12}C{sub 2}-dansyl labeled N-terminal amino acid was quantified using {sup 13}C{sub 2}-dansyl labeled amino acid standards. •The method provided accurate and precise results for quantifying intact and N-terminal truncated proteins within 8 h. -- Abstract: The N-terminal amino acids of proteins are important structure units for maintaining the biological function, localization, and interaction networks of proteins. Under different biological conditions, one or several N-terminal amino acids could be cleaved from an intact protein due to processes, such as proteolysis, resulting in the change of protein properties. Thus, the ability to quantify the N-terminal truncated forms of proteins is of great importance, particularly in the area of development and production of protein-based drugs where the relative quantity of the intact protein and its truncated form needs to be monitored. In this work, we describe a rapid method for absolute quantification of protein mixtures containing intact and N-terminal truncated proteins. This method is based on dansylation labeling of the N-terminal amino acids of proteins, followed by microwave-assisted acid hydrolysis of the proteins into amino acids. It is shown that dansyl labeled amino acids are stable in acidic conditions and can be quantified by liquid chromatography mass spectrometry (LC–MS) with the use of isotope analog standards.

  6. Scandium Terminal Imido Chemistry.

    Science.gov (United States)

    Lu, Erli; Chu, Jiaxiang; Chen, Yaofeng

    2018-02-20

    Research into transition metal complexes bearing multiply bonded main-group ligands has developed into a thriving and fruitful field over the past half century. These complexes, featuring terminal M═E/M≡E (M = transition metal; E = main-group element) multiple bonds, exhibit unique structural properties as well as rich reactivity, which render them attractive targets for inorganic/organometallic chemists as well as indispensable tools for organic/catalytic chemists. This fact has been highlighted by their widespread applications in organic synthesis, for example, as olefin metathesis catalysts. In the ongoing renaissance of transition metal-ligand multiple-bonding chemistry, there have been reports of M═E/M≡E interactions for the majority of the metallic elements of the periodic table, even some actinide metals. In stark contrast, the largest subgroup of the periodic table, rare-earth metals (Ln = Sc, Y, and lanthanides), have been excluded from this upsurge. Indeed, the synthesis of terminal Ln═E/Ln≡E multiple-bonding species lagged behind that of the transition metal and actinide congeners for decades. Although these species had been pursued since the discovery of a rare-earth metal bridging imide in 1991, such a terminal (nonpincer/bridging hapticities) Ln═E/Ln≡E bond species was not obtained until 2010. The scarcity is mainly attributed to the energy mismatch between the frontier orbitals of the metal and the ligand atoms. This renders the putative terminal Ln═E/Ln≡E bonds extremely reactive, thus resulting in the formation of aggregates and/or reaction with the ligand/environment, quenching the multiple-bond character. In 2010, the stalemate was broken by the isolation and structural characterization of the first rare-earth metal terminal imide-a scandium terminal imide-by our group. The double-bond character of the Sc═N bond was unequivocally confirmed by single-crystal X-ray diffraction. Theoretical investigations revealed the presence

  7. 10 CFR 600.244 - Termination for convenience.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false Termination for convenience. 600.244 Section 600.244 Energy DEPARTMENT OF ENERGY (CONTINUED) ASSISTANCE REGULATIONS FINANCIAL ASSISTANCE RULES Uniform... Requirements § 600.244 Termination for convenience. Except as provided in § 600.443 awards may be terminated in...

  8. 44 CFR 13.44 - Termination for convenience.

    Science.gov (United States)

    2010-10-01

    ... 44 Emergency Management and Assistance 1 2010-10-01 2010-10-01 false Termination for convenience. 13.44 Section 13.44 Emergency Management and Assistance FEDERAL EMERGENCY MANAGEMENT AGENCY... § 13.44 Termination for convenience. Except as provided in § 13.43 awards may be terminated in whole or...

  9. 15 CFR 930.115 - Termination of mediation.

    Science.gov (United States)

    2010-01-01

    ... 15 Commerce and Foreign Trade 3 2010-01-01 2010-01-01 false Termination of mediation. 930.115... MANAGEMENT FEDERAL CONSISTENCY WITH APPROVED COASTAL MANAGEMENT PROGRAMS Secretarial Mediation § 930.115 Termination of mediation. Mediation shall terminate: (a) At any time the Federal and State agencies agree to a...

  10. 23 CFR 635.125 - Termination of contract.

    Science.gov (United States)

    2010-04-01

    ... CONSTRUCTION AND MAINTENANCE Contract Procedures § 635.125 Termination of contract. (a) All contracts exceeding... 23 Highways 1 2010-04-01 2010-04-01 false Termination of contract. 635.125 Section 635.125... the termination will be effected and the basis for settlement. In addition, such contracts shall...

  11. SIRKULASI TERMINAL PENUMPANG KAPAL LAUT

    Directory of Open Access Journals (Sweden)

    Etsa Purnama Sari

    2014-01-01

    Full Text Available Wilayah Indonesia yang terdiri dari pulau dan perairan menjadikan angkutan laut menjadi salah satu sarana transportasi yang cukup efektif di negara ini. Daya angkut yang besar dan beragam serta biaya yang lebih murah dengan jarak jangkauan yang luas, membuat sarana ini banyak diminati oleh masyarakat sekaligus juga merupakan pendukung utama perkembangan kehidupan sosial budaya dan roda perekonomian. Untuk mendukung proses transportasi laut ini perlu sarana berupa pelabuhan. Pelabuhan dalam melakukan pelayanan terhadap kapal memiliki beberapa fasilitas pokok dan penunjang yang wajib dimiliki. Salah satunya adalah terminal penumpang kapal laut dengan berbagai kegiatan di dalamnya untuk kedatangan maupun keberangkatan. Masalah ketidaknyamanan dalam berkegiatan, jauhnya akses sirkulasi antara satu kegiatan dengan kegiatan kegiatan embarkasi dan debarkasi yang tidak teratur, pembagian jalur sirkulasi penumpang dan pengantar penumpang yang tidak jelas seringkali muncul akibat sirkulasi yang tidak direncanakan dengan baik pada terminal penumpang kapal laut. Bahkan tidak jarang dapat menimbulkan adanya calo tiket hingga adanya penumpang tanpa tiket yang dapat masuk ke dalam kapal hingga kapal berlayar. Perencanaan sebuah sirkulasi yang tepat pada terminal penumpang kapal laut memerlukan kajian terhadap unsur-unsur sirkulasi seperti pencapaian, pola sirkulasi, jalur sirkulasi, serta bentuk ruang sirkulasi. Kajian unsur-unsur ini selanjutnya diselidiki melalui penelusuran masalah dengan analisis deskriptif melalui penggambaran objek penelitian yang terdapat pada Terminal Penumpang Pelabuhan International Yokohama, Terminal Penumpang Pelabuhan Kobe dan Terminal Penumpang Pelabuhan Osanbashi Hall   As one of the largest archipelago country, sea transportation acts as one of the most effective means of transportation in Indonesia. Large and diverse carrying capacity, lower cost with wide range of distances, are factors which making sea

  12. The Practice of Hospital Intranet Terminal Access Control Solution

    Institute of Scientific and Technical Information of China (English)

    QI Shi-tao; TANG Li-ming

    2016-01-01

    Along with the increasingly urgent management needs of intranet terminals in hospital, and large scaled deployment of terminal management system, terminal access control has become one of the standard functions of terminal management. This paper mainly aims at some simple research for the system construction of hospital intranet terminal access control.

  13. Mechanism underlying bioinertness of self-assembled monolayers of oligo(ethyleneglycol)-terminated alkanethiols on gold: protein adsorption, platelet adhesion, and surface forces.

    Science.gov (United States)

    Hayashi, Tomohiro; Tanaka, Yusaku; Koide, Yuki; Tanaka, Masaru; Hara, Masahiko

    2012-08-07

    The mechanism underlying the bioinertness of the self-assembled monolayers of oligo(ethylene glycol)-terminated alkanethiol (OEG-SAM) was investigated with protein adsorption experiments, platelet adhesion tests, and surface force measurements with an atomic force microscope (AFM). In this work, we performed systematic analysis with SAMs having various terminal groups (-OEG, -OH, -COOH, -NH(2), and -CH(3)). The results of the protein adsorption experiment by the quartz crystal microbalance (QCM) method suggested that having one EG unit and the neutrality of total charges of the terminal groups are essential for protein-resistance. In particular, QCM with energy dissipation analyses indicated that proteins absorb onto the OEG-SAM via a very weak interaction compared with other SAMs. Contrary to the protein resistance, at least three EG units as well as the charge neutrality of the SAM are found to be required for anti-platelet adhesion. When the identical SAMs were formed on both AFM probe and substrate, our force measurements revealed that only the OEG-SAMs possessing more than two EG units showed strong repulsion in the range of 4 to 6 nm. In addition, we found that the SAMs with other terminal groups did not exhibit such repulsion. The repulsion between OEG-SAMs was always observed independent of solution conditions [NaCl concentration (between 0 and 1 M) and pH (between 3 and 11)] and was not observed in solution mixed with ethanol, which disrupts the three-dimensional network of the water molecules. We therefore concluded that the repulsion originated from structured interfacial water molecules. Considering the correlation between the above results, we propose that the layer of the structured interfacial water with a thickness of 2 to 3 nm (half of the range of the repulsion observed in the surface force measurements) plays an important role in deterring proteins and platelets from adsorption or adhesion.

  14. 48 CFR 22.1023 - Termination for default.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 1 2010-10-01 2010-10-01 false Termination for default... Amended 22.1023 Termination for default. As provided by the Act, any contractor failure to comply with the requirements of the contract clauses related to the Act may be grounds for termination for default (see...

  15. 49 CFR 18.44 - Termination for convenience.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 1 2010-10-01 2010-10-01 false Termination for convenience. 18.44 Section 18.44 Transportation Office of the Secretary of Transportation UNIFORM ADMINISTRATIVE REQUIREMENTS FOR GRANTS AND... Enforcement § 18.44 Termination for convenience. Except as provided in § 18.43 awards may be terminated in...

  16. 36 CFR 1207.44 - Termination for convenience.

    Science.gov (United States)

    2010-07-01

    ... 36 Parks, Forests, and Public Property 3 2010-07-01 2010-07-01 false Termination for convenience. 1207.44 Section 1207.44 Parks, Forests, and Public Property NATIONAL ARCHIVES AND RECORDS... Termination for convenience. Except as provided in § 1207.43 awards may be terminated in whole or in part only...

  17. 45 CFR 1157.44 - Termination for convenience.

    Science.gov (United States)

    2010-10-01

    ... 45 Public Welfare 3 2010-10-01 2010-10-01 false Termination for convenience. 1157.44 Section 1157.44 Public Welfare Regulations Relating to Public Welfare (Continued) NATIONAL FOUNDATION ON THE ARTS... Enforcement § 1157.44 Termination for convenience. Except as provided in § 1157.43 awards may be terminated in...

  18. 45 CFR 602.44 - Termination for convenience.

    Science.gov (United States)

    2010-10-01

    ... 45 Public Welfare 3 2010-10-01 2010-10-01 false Termination for convenience. 602.44 Section 602.44 Public Welfare Regulations Relating to Public Welfare (Continued) NATIONAL SCIENCE FOUNDATION UNIFORM... Requirements § 602.44 Termination for convenience. Except as provided in § 602.43 awards may be terminated in...

  19. System program for MICRO-CAMAC terminal system

    International Nuclear Information System (INIS)

    Sasajima, Yoji; Yamada, Takayuki; Yagi, Hideyuki; Ishiguro, Misako

    1979-08-01

    A JAERI on-line network system was developed and exists for on-line data processing of nuclear instrumentation. As terminal systems for the network system, the one with a Micro -8 micro-computer is used. By modifying the control program for Micro-8 terminal system, a system program has been developed for a MICRO-CAMAC terminal system, which is controlled by a micro-computer framed within the CAMAC Crate Controller. In this report are described software specifications of the MICRO -CAMAC terminal system and its operation method. (author)

  20. 29 CFR 97.44 - Termination for convenience.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 1 2010-07-01 2010-07-01 true Termination for convenience. 97.44 Section 97.44 Labor Office of the Secretary of Labor UNIFORM ADMINISTRATIVE REQUIREMENTS FOR GRANTS AND COOPERATIVE... § 97.44 Termination for convenience. Except as provided in § 97.43 awards may be terminated in whole or...

  1. 43 CFR 12.84 - Termination for convenience.

    Science.gov (United States)

    2010-10-01

    ... 43 Public Lands: Interior 1 2010-10-01 2010-10-01 false Termination for convenience. 12.84 Section 12.84 Public Lands: Interior Office of the Secretary of the Interior ADMINISTRATIVE AND AUDIT... Termination for convenience. Except as provided in § 12.83 awards may be terminated in whole or in part only...

  2. 7 CFR 3016.44 - Termination for convenience.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 15 2010-01-01 2010-01-01 false Termination for convenience. 3016.44 Section 3016.44 Agriculture Regulations of the Department of Agriculture (Continued) OFFICE OF THE CHIEF FINANCIAL OFFICER... Termination for convenience. Except as provided in § 3016.43 awards may be terminated in whole or in part only...

  3. 78 FR 14361 - U.S. Steel Tubular Products, Inc., Mckeesport Tubular Operations Division, Subsidiary of United...

    Science.gov (United States)

    2013-03-05

    ... Products, Inc., Mckeesport Tubular Operations Division, Subsidiary of United States Steel Corporation, Mckeesport, PA; Notice of Initiation of Investigation To Terminate Certification of Eligibility Pursuant to... Tubular Products, McKeesport Tubular Operations Division, Subsidiary of United States Steel Corporation...

  4. 24 CFR 85.44 - Termination for convenience.

    Science.gov (United States)

    2010-04-01

    ... 24 Housing and Urban Development 1 2010-04-01 2010-04-01 false Termination for convenience. 85.44 Section 85.44 Housing and Urban Development Office of the Secretary, Department of Housing and Urban... § 85.44 Termination for convenience. Except as provided in § 85.43 awards may be terminated in whole or...

  5. Selection of Air Terminal Device

    DEFF Research Database (Denmark)

    Nielsen, Peter V.

    This paper discusses the selection of the air terminal device for the experiments and numerical prediction in the International Energy Agency Annex 20 work: Air Flow Pattern within Buildings,......This paper discusses the selection of the air terminal device for the experiments and numerical prediction in the International Energy Agency Annex 20 work: Air Flow Pattern within Buildings,...

  6. Functionalization of hydroxyl terminated polybutadiene with ...

    Indian Academy of Sciences (India)

    CBDT), has been covalently attached at the terminal carbon atoms of the hydroxyl terminated polybutadiene (HTPB) backbone. The modification of HTPB backbone by CBDT molecule does not affect the unique physico-chemical properties such ...

  7. Structure of the afferent terminals in terminal ganglion of a cricket and persistent homology.

    Directory of Open Access Journals (Sweden)

    Jacob Brown

    Full Text Available We use topological data analysis to investigate the three dimensional spatial structure of the locus of afferent neuron terminals in crickets Acheta domesticus. Each afferent neuron innervates a filiform hair positioned on a cercus: a protruding appendage at the rear of the animal. The hairs transduce air motion to the neuron signal that is used by a cricket to respond to the environment. We stratify the hairs (and the corresponding afferent terminals into classes depending on hair length, along with position. Our analysis uncovers significant structure in the relative position of these terminal classes and suggests the functional relevance of this structure. Our method is very robust to the presence of significant experimental and developmental noise. It can be used to analyze a wide range of other point cloud data sets.

  8. Accuracy Analysis of Lunar Lander Terminal Guidance Algorithm

    Directory of Open Access Journals (Sweden)

    E. K. Li

    2017-01-01

    Full Text Available This article studies a proposed analytical algorithm of the terminal guidance for the lunar lander. The analytical solution, which forms the basis of the algorithm, was obtained for a constant acceleration trajectory and thrust vector orientation programs that are essentially linear with time. The main feature of the proposed algorithm is a completely analytical solution to provide the lander terminal guidance to the desired spot in 3D space when landing on the atmosphereless body with no numerical procedures. To reach 6 terminal conditions (components of position and velocity vectors at the final time are used 6 guidance law parameters, namely time-to-go, desired value of braking deceleration, initial values of pitch and yaw angles and rates of their change. In accordance with the principle of flexible trajectories, this algorithm assumes the implementation of a regularly updated control program that ensures reaching terminal conditions from the current state that corresponds to the control program update time. The guidance law parameters, which ensure that terminal conditions are reached, are generated as a function of the current phase coordinates of a lander. The article examines an accuracy and reliability of the proposed analytical algorithm that provides the terminal guidance of the lander in 3D space through mathematical modeling of the lander guidance from the circumlunar pre-landing orbit to the desired spot near the lunar surface. A desired terminal position of the lunar lander is specified by the selenographic latitude, longitude and altitude above the lunar surface. The impact of variations in orbital parameters on the terminal guidance accuracy has been studied. By varying the five initial orbit parameters (obliquity, ascending node longitude, argument of periapsis, periapsis height, apoapsis height when the terminal spot is fixed the statistic characteristics of the terminal guidance algorithm error according to the terminal

  9. Operational Optimization in Port Container Terminals

    DEFF Research Database (Denmark)

    As a result of the significant increase in worldwide containerized transportation the development of efficient handling systems in marine terminals has become very important for port competitiveness. In order to optimize the productivity the total handling time for containers in the terminal must...... be minimized. An overview of the different operational problems in port container terminals is presented and an aggregated model and solution approach is shown. Next, there will be focused on the yard storage problem and a mathematical formulation and solution proposals will be presented....

  10. Crystallization of the C-terminal domain of the addiction antidote CcdA in complex with its toxin CcdB

    International Nuclear Information System (INIS)

    Buts, Lieven; De Jonge, Natalie; Loris, Remy; Wyns, Lode; Dao-Thi, Minh-Hoa

    2005-01-01

    The CcdA C-terminal domain was crystallized in complex with CcdB in two crystal forms that diffract to beyond 2.0 Å resolution. CcdA and CcdB are the antidote and toxin of the ccd addiction module of Escherichia coli plasmid F. The CcdA C-terminal domain (CcdA C36 ; 36 amino acids) was crystallized in complex with CcdB (dimer of 2 × 101 amino acids) in three different crystal forms, two of which diffract to high resolution. Form II belongs to space group P2 1 2 1 2 1 , with unit-cell parameters a = 37.6, b = 60.5, c = 83.8 Å and diffracts to 1.8 Å resolution. Form III belongs to space group P2 1 , with unit-cell parameters a = 41.0, b = 37.9, c = 69.6 Å, β = 96.9°, and diffracts to 1.9 Å resolution

  11. Terminal Ballistics

    CERN Document Server

    Rosenberg, Zvi

    2012-01-01

    This book covers the important issues of terminal ballistics in a comprehensive way combining experimental data, numerical simulations and analytical modeling. The first chapter reviews the experimental equipment which are used for ballistic tests and the diagnostics for material characterization under impulsive loading conditions. The second chapter covers essential features of the codes which are used for terminal ballistics such as the Euler vs. Lagrange schemes and meshing techniques, as well as the most popular material models. The third chapter, devoted to the penetration mechanics of rigid penetrators, brings the update of modeling in this field. The fourth chapter deals with plate perforation and the fifth chapter deals with the penetration mechanics of shaped charge jets and eroding long rods. The last two chapters discuss several techniques for the disruption and defeating of the main threats in armor design. Throughout the book the authors demonstrate the advantages of numerical simulations in unde...

  12. Alta peab tasuma Kalevile mais / Kersti Saar

    Index Scriptorium Estoniae

    Saar, Kersti

    2008-01-01

    Indrek Rahumaa juhitav Alta Capital peab tasuma Oliver Kruudale Kalevi tütarfirmade eest 660 miljonit krooni hiljemalt 30. maiks. Vt. samas: Investorid teavad tehingu hinda ja lõplikku tähtaega. Diagramm: Kalevi turuväärtus jääb Alta müügihinnale alla

  13. Improved transmission of electrostatic accelerator in a wide range of terminal voltages by controlling the focal strength of entrance acceleration tube

    Science.gov (United States)

    Lobanov, Nikolai R.; Tunningley, Thomas; Linardakis, Peter

    2018-04-01

    Tandem electrostatic accelerators often require the flexibility to operate at a variety of terminal voltages to accommodate various user requirements. However, the ion beam transmission will only be optimal for a limited range of terminal voltages. This paper describes the operational performance of a novel focusing system that expands the range of terminal voltages for optimal transmission. This is accomplished by controlling the gradient of the entrance of the low-energy tube, providing an additional focusing element. In this specific case it is achieved by applying up to 150 kV to the fifth electrode of the first unit of the accelerator tube. Numerical simulations and beam transmission tests have been performed to confirm the effectiveness of the lens. An analytical expression has been derived describing its focal properties. These tests demonstrate that the entrance lens control eliminates the need to short out sections of the tube for operation at low terminal voltage.

  14. Epimerization-free C-terminal peptide activation, elongation and cyclization

    NARCIS (Netherlands)

    Popović, S.

    2015-01-01

    C-terminal peptide activation and cyclization reactions are generally accompanied with epimerization (partial loss of C‐terminal stereointegrity). Therefore, the focus of this thesis was to develop epimerization-free methods for C-terminal peptide activation to enable C-terminal peptide elongation

  15. VOLTTRON Lite: Integration Platform for the Transactional Network

    Energy Technology Data Exchange (ETDEWEB)

    Haack, Jereme N.; Katipamula, Srinivas; Akyol, Bora A.; Lutes, Robert G.

    2013-10-31

    In FY13, Pacific Northwest National Laboratory (PNNL) with funding from the Department of Energy’s (DOE’s) Building Technologies Office (BTO) designed, prototyped and tested a transactional network platform. The platform is intended to support energy, operational and financial transactions between any networked entities (equipment, organizations, buildings, grid, etc.). Initially, in FY13, the concept demonstrated transactions between packaged rooftop units (RTUs) and the electric grid using applications or “agents” that reside on the platform, on the equipment, on local building controller or in the Cloud. This document describes the core of the transactional network platform, the Volttron Lite™ software and associated services hosted on the platform. Future enhancements are also discussed. The appendix of the document provides examples of how to use the various services hosted on the platform.

  16. Transaction-Based Controls for Building-Grid Integration: VOLTTRON™

    Energy Technology Data Exchange (ETDEWEB)

    Akyol, Bora A.; Haack, Jereme N.; Hernandez, George; Katipamula, Srinivas; Widergren, Steven E.

    2015-07-01

    The U.S. Department of Energy’s (DOE’s) Building Technologies Office (BTO) is supporting the development of a “transactional network” concept that supports energy, operational, and financial transactions between building systems (e.g., rooftop units -- RTUs), and the electric power grid using applications, or 'agents', that reside either on the equipment, on local building controllers, or in the Cloud. The transactional network vision is delivered using a real-time, scalable reference platform called VOLTTRON that supports the needs of the changing energy system. VOLTTRON is an agent execution and an innovative distributed control and sensing software platform that supports modern control strategies, including agent-based and transaction-based controls. It enables mobile and stationary software agents to perform information gathering, processing, and control actions.

  17. Big Data, Internet of Things and Cloud Convergence--An Architecture for Secure E-Health Applications.

    Science.gov (United States)

    Suciu, George; Suciu, Victor; Martian, Alexandru; Craciunescu, Razvan; Vulpe, Alexandru; Marcu, Ioana; Halunga, Simona; Fratu, Octavian

    2015-11-01

    Big data storage and processing are considered as one of the main applications for cloud computing systems. Furthermore, the development of the Internet of Things (IoT) paradigm has advanced the research on Machine to Machine (M2M) communications and enabled novel tele-monitoring architectures for E-Health applications. However, there is a need for converging current decentralized cloud systems, general software for processing big data and IoT systems. The purpose of this paper is to analyze existing components and methods of securely integrating big data processing with cloud M2M systems based on Remote Telemetry Units (RTUs) and to propose a converged E-Health architecture built on Exalead CloudView, a search based application. Finally, we discuss the main findings of the proposed implementation and future directions.

  18. N-terminal truncation enables crystallization of the receptor-binding domain of the FedF bacterial adhesin

    Energy Technology Data Exchange (ETDEWEB)

    De Kerpel, Maia; Van Molle, Inge [Department of Ultrastructure, Vrije Universiteit Brussel (VUB), Flanders Interuniversity Institute for Biotechnology (VIB), Pleinlaan 2, 1050 Brussels (Belgium); Brys, Lea [Department of Cellular and Molecular Immunology, Vrije Universiteit Brussel (VUB), Flanders Interuniversity Institute for Biotechnology (VIB), Pleinlaan 2, 1050 Brussels (Belgium); Wyns, Lode; De Greve, Henri; Bouckaert, Julie, E-mail: bouckaej@vub.ac.be [Department of Ultrastructure, Vrije Universiteit Brussel (VUB), Flanders Interuniversity Institute for Biotechnology (VIB), Pleinlaan 2, 1050 Brussels (Belgium)

    2006-12-01

    The N-terminal receptor-binding domain of the FedF adhesin from enterotoxigenic E. coli has been crystallized. This required the deletion of its first 14 residues, which are also cleaved off naturally. FedF is the two-domain tip adhesin of F18 fimbriae from enterotoxigenic Escherichia coli. Bacterial adherence, mediated by the N-terminal receptor-binding domain of FedF to carbohydrate receptors on intestinal microvilli, causes diarrhoea and oedema disease in newly weaned piglets and induces the secretion of Shiga toxins. A truncate containing only the receptor-binding domain of FedF was found to be further cleaved at its N-terminus. Reconstruction of this N-terminal truncate rendered FedF amenable to crystallization, resulting in crystals with space group P2{sub 1}2{sub 1}2{sub 1} and unit-cell parameters a = 36.20, b = 74.64, c = 99.03 Å that diffracted to beyond 2 Å resolution. The binding specificity of FedF was screened for on a glycan array, exposing 264 glycoconjugates, to identify specific receptors for cocrystallization with FedF.

  19. Windows Terminal Servers Orchestration

    Science.gov (United States)

    Bukowiec, Sebastian; Gaspar, Ricardo; Smith, Tim

    2017-10-01

    Windows Terminal Servers provide application gateways for various parts of the CERN accelerator complex, used by hundreds of CERN users every day. The combination of new tools such as Puppet, HAProxy and Microsoft System Center suite enable automation of provisioning workflows to provide a terminal server infrastructure that can scale up and down in an automated manner. The orchestration does not only reduce the time and effort necessary to deploy new instances, but also facilitates operations such as patching, analysis and recreation of compromised nodes as well as catering for workload peaks.

  20. USA väärtus orkaanis / Piret Loone

    Index Scriptorium Estoniae

    Loone, Piret

    2005-01-01

    Seoses New Orleansi tabanud orkaan Katrina katastroofiga süüdistab autor president Bushi riigi halvas ettevalmistamises olukorraga toime tulemiseks. Autor peab föderaalse hädaolukordade agentuuri juhti Michael Browni ebakompetentseks oma ametikohale, viidates ka president Bushi ja Michael Browni omavahelisele seotusele

  1. Coal terminal directory

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2008-06-15

    The directory gives a comprehensive listing of the world's coal terminals, in a total of 50 countries including information on throughput, facilities, storage capacity, and vessel size limitation.

  2. Size-change termination and transition invariants

    DEFF Research Database (Denmark)

    Heizmann, Matthias; Jones, Neil; Podelski, Andreas

    2010-01-01

    Two directions of recent work on program termination use the concepts of size-change termination resp. transition invariants. The difference in the setting has as consequence the inherent incomparability of the analysis and verification methods that result from this work. Yet, in order...

  3. 48 CFR 32.109 - Termination financing.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 1 2010-10-01 2010-10-01 false Termination financing. 32... CONTRACTING REQUIREMENTS CONTRACT FINANCING Non-Commercial Item Purchase Financing 32.109 Termination financing. To encourage contractors to invest their own funds in performance despite the susceptibility of...

  4. 12 CFR 611.1223 - Plan of termination-contents.

    Science.gov (United States)

    2010-01-01

    ...; (4) The anticipated benefits and potential disadvantages of the termination; (5) The right of certain.... Summarize the plan of termination. (3) Benefits and disadvantages. Provide an enumerated statement of the anticipated benefits and potential disadvantages of the termination. (4) Recommendation. Explain the board's...

  5. Multi-terminal memtransistors from polycrystalline monolayer molybdenum disulfide

    Science.gov (United States)

    Sangwan, Vinod K.; Lee, Hong-Sub; Bergeron, Hadallia; Balla, Itamar; Beck, Megan E.; Chen, Kan-Sheng; Hersam, Mark C.

    2018-02-01

    Memristors are two-terminal passive circuit elements that have been developed for use in non-volatile resistive random-access memory and may also be useful in neuromorphic computing. Memristors have higher endurance and faster read/write times than flash memory and can provide multi-bit data storage. However, although two-terminal memristors have demonstrated capacity for basic neural functions, synapses in the human brain outnumber neurons by more than a thousandfold, which implies that multi-terminal memristors are needed to perform complex functions such as heterosynaptic plasticity. Previous attempts to move beyond two-terminal memristors, such as the three-terminal Widrow-Hoff memristor and field-effect transistors with nanoionic gates or floating gates, did not achieve memristive switching in the transistor. Here we report the experimental realization of a multi-terminal hybrid memristor and transistor (that is, a memtransistor) using polycrystalline monolayer molybdenum disulfide (MoS2) in a scalable fabrication process. The two-dimensional MoS2 memtransistors show gate tunability in individual resistance states by four orders of magnitude, as well as large switching ratios, high cycling endurance and long-term retention of states. In addition to conventional neural learning behaviour of long-term potentiation/depression, six-terminal MoS2 memtransistors have gate-tunable heterosynaptic functionality, which is not achievable using two-terminal memristors. For example, the conductance between a pair of floating electrodes (pre- and post-synaptic neurons) is varied by a factor of about ten by applying voltage pulses to modulatory terminals. In situ scanning probe microscopy, cryogenic charge transport measurements and device modelling reveal that the bias-induced motion of MoS2 defects drives resistive switching by dynamically varying Schottky barrier heights. Overall, the seamless integration of a memristor and transistor into one multi-terminal device could

  6. Folding units in calcium vector protein of amphioxus: Structural and functional properties of its amino- and carboxy-terminal halves.

    Science.gov (United States)

    Baladi, S; Tsvetkov, P O; Petrova, T V; Takagi, T; Sakamoto, H; Lobachov, V M; Makarov, A A; Cox, J A

    2001-04-01

    Muscle of amphioxus contains large amounts of a four EF-hand Ca2+-binding protein, CaVP, and its target, CaVPT. To study the domain structure of CaVP and assess the structurally important determinants for its interaction with CaVPT, we expressed CaVP and its amino (N-CaVP) and carboxy-terminal halves (C-CaVP). The interactive properties of recombinant and wild-type CaVP are very similar, despite three post-translational modifications in the wild-type protein. N-CaVP does not bind Ca2+, shows a well-formed hydrophobic core, and melts at 44 degrees C. C-CaVP binds two Ca2+ with intrinsic dissociation constants of 0.22 and 140 microM (i.e., very similar to the entire CaVP). The metal-free domain in CaVP and C-CaVP shows no distinct melting transition, whereas its 1Ca2+ and 2Ca2+) forms melt in the 111 degrees -123 degrees C range, suggesting that C-CaVP and the carboxy- domain of CaVP are natively unfolded in the metal-free state and progressively gain structure upon binding of 1Ca2+ and 2Ca2+. Thermal denaturation studies provide evidence for interdomain interaction: the apo, 1Ca2+ and 2Ca2+ states of the carboxy-domain destabilize to different degrees the amino-domain. Only C-CaVP forms a Ca2+-dependent 1:1 complex with CaVPT. Our results suggest that the carboxy-terminal domain of CaVP interacts with CaVPT and that the amino-terminal lobe modulates this interaction.

  7. Comprehensive study of gate-terminated and source-terminated field-plate 0.13 µm NMOS transistors

    International Nuclear Information System (INIS)

    Chiu, Hsien-Chin; Lin, Shao-Wei; Cheng, Chia-Shih; Wei, Chien-Cheng

    2008-01-01

    This study systematically investigated microwave noise, power and linearity characteristics of field-plate (FP) 0.13 µm CMOS transistors in which the field-plate metal is connected to the gate terminal and the source terminal. The gate-terminated FP NMOS (FP-G NMOS) provided the best noise figure (NF) at 6 GHz compared with standard devices and the source-terminated FP device (FP-S NMOS) as the lowest gate resistance (R g ) was obtained by this structure. By adopting the field-plate metal in NMOS, both FP-S and FP-G devices achieved higher current density at high gate bias voltages. Moreover, these two devices also had higher efficiency under high drain-to-source voltages at the high input power swing. The third-order inter-modulation product (IM3) is −39.4 dBm for FP-S NMOS at P in of −20 dBm; the corresponding values for FP-G and standard devices are −34.9 dBm and −37.3 dBm, respectively. Experimental results indicate that the FP-G architecture is suitable for low noise applications and FP-S is suitable for high power and high linearity operation

  8. Börsiindeks Talse kerkis eelmisel aastal 57,1%

    Index Scriptorium Estoniae

    2005-01-01

    Tallinna börsi indeks Talse tõusis 2004. aastaga 448,82 punktini, börsiettevõtete turuväärtus kasvas 4,59 mld euroni, edukalt käivitus Tallinnas, Riias ja Helsingis kasutusele võetud kauplemissüsteem SAXESS, kasvas piiriüleste väärtpaberitehingute hulk

  9. Jussi Mustonen: Soome investorid ootavad kuni Eestis hinnad langevad / Jussi Mustonen ; intervjueerinud Mikk Salu

    Index Scriptorium Estoniae

    Mustonen, Jussi

    2009-01-01

    Soome tööstuse keskliidu peaökonomist ütleb seoses Eesti eesmärgiga ühineda euroalaga, et euro annab stabiilsust, aga see ei ole imerohi. Eesti muutub Soome investoritele atraktiivseks investeerimispiirkonnaks, kui hinnad alanevad, varade väärtus langeb. Soome majanduse olukorrast, abinõudest oma majanduse stimuleerimiseks

  10. Terminal-Dependent Statistical Inference for the FBSDEs Models

    Directory of Open Access Journals (Sweden)

    Yunquan Song

    2014-01-01

    Full Text Available The original stochastic differential equations (OSDEs and forward-backward stochastic differential equations (FBSDEs are often used to model complex dynamic process that arise in financial, ecological, and many other areas. The main difference between OSDEs and FBSDEs is that the latter is designed to depend on a terminal condition, which is a key factor in some financial and ecological circumstances. It is interesting but challenging to estimate FBSDE parameters from noisy data and the terminal condition. However, to the best of our knowledge, the terminal-dependent statistical inference for such a model has not been explored in the existing literature. We proposed a nonparametric terminal control variables estimation method to address this problem. The reason why we use the terminal control variables is that the newly proposed inference procedures inherit the terminal-dependent characteristic. Through this new proposed method, the estimators of the functional coefficients of the FBSDEs model are obtained. The asymptotic properties of the estimators are also discussed. Simulation studies show that the proposed method gives satisfying estimates for the FBSDE parameters from noisy data and the terminal condition. A simulation is performed to test the feasibility of our method.

  11. Role of multiple phosphorylation sites in the COOH-terminal tail of aquaporin-2 for water transport: evidence against channel gating

    DEFF Research Database (Denmark)

    Moeller, Hanne B; Macaulay, Nanna; Knepper, Mark A

    2009-01-01

    demonstrated that lack of phosphorylation at S256, S261, S264, or S269 had no effect on AQP2 unit water transport. Similarly, no effect on AQP2 unit water transport was observed for the 264D and 269D forms, indicating that phosphorylation of the COOH-terminal tail of AQP2 is not involved in gating......Arginine vasopressin (AVP)-regulated phosphorylation of the water channel aquaporin-2 (AQP2) at serine 256 (S256) is essential for its accumulation in the apical plasma membrane of collecting duct principal cells. In this study, we examined the role of additional AVP-regulated phosphorylation sites...... in the COOH-terminal tail of AQP2 on protein function. When expressed in Xenopus laevis oocytes, prevention of AQP2 phosphorylation at S256A (S256A-AQP2) reduced osmotic water permeability threefold compared with wild-type (WT) AQP2-injected oocytes. In contrast, prevention of AQP2 single phosphorylation at S...

  12. 9 CFR 3.117 - Terminal facilities.

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Terminal facilities. 3.117 Section 3... Marine Mammals Transportation Standards § 3.117 Terminal facilities. Carriers and intermediate handlers... facility of any carrier or intermediate handler where marine mammal shipments are maintained must be...

  13. Bargaining in Mergers and Termination Fees

    NARCIS (Netherlands)

    Weitzel, U.; Rosenkranz, S.

    We model takeovers as a bargaining process and explain termination fees for, both, the target and the acquirer, subject to parties’ bargaining power and outside options. In equilibrium, termination fees are offered by firms with outside options in exchange for a greater share of merger synergies.

  14. 48 CFR 52.249-6 - Termination (Cost-Reimbursement).

    Science.gov (United States)

    2010-10-01

    ...-Reimbursement). 52.249-6 Section 52.249-6 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION....249-6 Termination (Cost-Reimbursement). As prescribed in 49.503(a)(1), insert the following clause: Termination (Cost-Reimbursement) (MAY 2004) (a) The Government may terminate performance of work under this...

  15. Economic viability of thin-film tandem solar modules in the United States

    Science.gov (United States)

    Sofia, Sarah E.; Mailoa, Jonathan P.; Weiss, Dirk N.; Stanbery, Billy J.; Buonassisi, Tonio; Peters, I. Marius

    2018-05-01

    Tandem solar cells are more efficient but more expensive per unit area than established single-junction (SJ) solar cells. To understand when specific tandem architectures should be utilized, we evaluate the cost-effectiveness of different II-VI-based thin-film tandem solar cells and compare them to the SJ subcells. Levelized cost of electricity (LCOE) and energy yield are calculated for four technologies: industrial cadmium telluride and copper indium gallium selenide, and their hypothetical two-terminal (series-connected subcells) and four-terminal (electrically independent subcells) tandems, assuming record SJ quality subcells. Different climatic conditions and scales (residential and utility scale) are considered. We show that, for US residential systems with current balance-of-system costs, the four-terminal tandem has the lowest LCOE because of its superior energy yield, even though it has the highest US per watt (US W-1) module cost. For utility-scale systems, the lowest LCOE architecture is the cadmium telluride single junction, the lowest US W-1 module. The two-terminal tandem requires decreased subcell absorber costs to reach competitiveness over the four-terminal one.

  16. 42 CFR 422.510 - Termination of contract by CMS.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 3 2010-10-01 2010-10-01 false Termination of contract by CMS. 422.510 Section 422... Advantage Organizations § 422.510 Termination of contract by CMS. (a) Termination by CMS. CMS may at any time terminate a contract if CMS determines that the MA organization meets any of the following: (1...

  17. Optical control system for high-voltage terminals

    International Nuclear Information System (INIS)

    Bicek, J.J.

    1978-01-01

    An optical control system for the control of devices in the terminal of an electrostatic accelerator includes a laser that is modulated by a series of preselected codes produced by an encoder. A photodiode receiver is placed in the laser beam at the high-voltage terminal of an electrostatic accelerator. A decoder connected to the photodiode decodes the signals to provide control impulses for a plurality of devices at the high voltage of the terminal

  18. 7 CFR 1465.25 - Contract violations and termination.

    Science.gov (United States)

    2010-01-01

    .... (2) If NRCS terminates a contract due to breach of contract, or the participant voluntarily... 7 Agriculture 10 2010-01-01 2010-01-01 false Contract violations and termination. 1465.25 Section... ASSISTANCE Contracts § 1465.25 Contract violations and termination. (a) If NRCS determines that a participant...

  19. 29 CFR 408.7 - Terminal trusteeship financial report.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 2 2010-07-01 2010-07-01 false Terminal trusteeship financial report. 408.7 Section 408.7...-MANAGEMENT STANDARDS LABOR ORGANIZATION TRUSTEESHIP REPORTS § 408.7 Terminal trusteeship financial report... a terminal financial report, and one copy, with the Office of Labor-Management Standards, on Form LM...

  20. [Terminal phase hydration, pain and delirium

    DEFF Research Database (Denmark)

    Heick, A.

    2009-01-01

    Hydration of the terminal patient may relieve confusion and complaints of "dry mouth". But it may worsen oedema of the brain, lungs, and extremities, worsen terminal rattling and cause a need for frequent changing of diapers. The decision of whether and how to treat a dying patient with fluids...

  1. 28 CFR 2.43 - Early termination.

    Science.gov (United States)

    2010-07-01

    ... terminated because there is a likelihood that the parolee will engage in conduct violating any criminal law... shall review the status of the parolee to determine the need for continued supervision. The Commission shall also conduct a status review whenever the supervision officer recommends early termination of the...

  2. 42 CFR 423.509 - Termination of contract by CMS.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 3 2010-10-01 2010-10-01 false Termination of contract by CMS. 423.509 Section 423... Contracts with Part D plan sponsors § 423.509 Termination of contract by CMS. (a) Termination by CMS. CMS may at any time terminate a contract if CMS determines that the Part D plan sponsor meets any of the...

  3. 48 CFR 252.237-7007 - Termination for default.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 3 2010-10-01 2010-10-01 false Termination for default... of Provisions And Clauses 252.237-7007 Termination for default. As prescribed in 237.7003(b), use the following clause: Termination for Default (DEC 1991) (a) This clause supplements and is in addition to the...

  4. 41 CFR 105-71.144 - Termination for convenience.

    Science.gov (United States)

    2010-07-01

    ... 41 Public Contracts and Property Management 3 2010-07-01 2010-07-01 false Termination for convenience. 105-71.144 Section 105-71.144 Public Contracts and Property Management Federal Property... Termination for convenience. Except as provided in § 105-71.143 awards may be terminated in whole or in part...

  5. Minimum Efficient Scale (MES) and preferred scale of container terminals

    OpenAIRE

    Kaselimi, Evangelia N.; Notteboom, Theo E.; Pallis, Athanasios A.; Farrell, Sheila

    2011-01-01

    Abstract: The decision on the scale of a port terminal affects the terminals managerial, operational and competitive position in all the phases of its life. It also affects competition structures in the port in which the terminal is operating, and has a potential impact on other terminals. Port authorities and terminal operators need to know the scale of the terminal when engaging in concession agreements. In economic theory the scale of a plant/firm is typically defined in relation to the Mi...

  6. [Terminal phase hydration, pain and delirium

    DEFF Research Database (Denmark)

    Heick, A.

    2009-01-01

    Hydration of the terminal patient may relieve confusion and complaints of "dry mouth". But it may worsen oedema of the brain, lungs, and extremities, worsen terminal rattling and cause a need for frequent changing of diapers. The decision of whether and how to treat a dying patient with fluids sh...

  7. A triclinic crystal structure of the carboxy-terminal domain of HIV-1 capsid protein with four molecules in the asymmetric unit reveals a novel packing interface

    International Nuclear Information System (INIS)

    Lampel, Ayala; Yaniv, Oren; Berger, Or; Bacharach, Eran; Gazit, Ehud; Frolow, Felix

    2013-01-01

    The triclinic structure of the HIV-1 capsid protein contains four molecules in the asymmetric unit that form a novel packing interface that could conceivably resemble an intermediate structure that is involved in the early steps of HIV-1 assembly. The Gag precursor is the major structural protein of the virion of human immunodeficiency virus-1 (HIV-1). Capsid protein (CA), a cleavage product of Gag, plays an essential role in virus assembly both in Gag-precursor multimerization and in capsid core formation. The carboxy-terminal domain (CTD) of CA contains 20 residues that are highly conserved across retroviruses and constitute the major homology region (MHR). Genetic evidence implies a role for the MHR in interactions between Gag precursors during the assembly of the virus, but the structural basis for this role remains elusive. This paper describes a novel triclinic structure of the HIV-1 CA CTD at 1.6 Å resolution with two canonical dimers of CA CTD in the asymmetric unit. The canonical dimers form a newly identified packing interface where interactions of four conserved MHR residues take place. This is the first structural indication that these MHR residues participate in the putative CTD–CTD interactions. These findings suggest that the molecules forming this novel interface resemble an intermediate structure that participates in the early steps of HIV-1 assembly. This interface may therefore provide a novel target for antiviral drugs

  8. 42 CFR 421.205 - Termination by the Secretary.

    Science.gov (United States)

    2010-10-01

    ... for termination. The Secretary may terminate a contract with a carrier at any time if he or she... performed its function in a manner inconsistent with the effective and efficient administration of the... intent to terminate the contract, the carrier may request a hearing within 20 days after the date on the...

  9. Coach terminal as important element of transport infrastructure

    Directory of Open Access Journals (Sweden)

    V. Gromule

    2007-10-01

    Full Text Available The determination of the coach terminal as passenger logistics hub is described. The factors responsible for successful functioning of this hub are discussed. The location of the coach terminal is one of the important factors. The present coach terminal is located in the heart of the city where land availability is critical. The simulation model of the terminal was developed to complement the design and construction of a new one. The used simulation package VISSIM has visual reference to assist in explaining the complexity of transport node’s job and analysis of possible congestions. During the development of the modelling the critical bottlenecks are identified and decisions are taken to reduce the risk of their occurrence, the solution being immediately incorporated into the final design of the coach terminal under development.

  10. Productivity simulation model for optimization of maritime container terminals

    Directory of Open Access Journals (Sweden)

    Elen TWRDY

    2009-01-01

    Full Text Available This article describes a proposed productivity simulation model enabling container terminal operators to find optimization possibilities. A research of more than forty terminals has been done, in order to provide a helping tool for maritime container terminals. By applying an adequate simulation model, it is possible to measure and increase the productivity in all subsystem of the maritime container terminal. Management of a maritime container terminal includes a vast number of different financial and operational decisions. Financial decisions are often in a direct connection with investments in infrastructure and handling equipment. Such investments are very expensive. Therefore, they must give back the invested money as soon as possible. On the other hand, some terminals are limited by the physical extension and are forced to increase annual throughput only with sophisticated equipment on the berth side and on the yard as well. Considering all these important facts in container and shipping industry, the proposed simulation model gives a helping tool for checking the productivity and its time variation and monitoring competitiveness of a certain maritime terminal with terminals from the same group.

  11. 29 CFR 408.8 - Terminal trusteeship information report.

    Science.gov (United States)

    2010-07-01

    ... information report. There shall be filed at the same time that the terminal trusteeship financial report is filed a terminal trusteeship information report on Form LM-16. If in answer to Item 6 of Form LM-16... 29 Labor 2 2010-07-01 2010-07-01 false Terminal trusteeship information report. 408.8 Section 408...

  12. 47 CFR 25.134 - Licensing provisions of Very Small Aperture Terminal (VSAT) and C-band Small Aperture Terminal...

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 2 2010-10-01 2010-10-01 false Licensing provisions of Very Small Aperture Terminal (VSAT) and C-band Small Aperture Terminal (CSAT) networks. 25.134 Section 25.134 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) COMMON CARRIER SERVICES SATELLITE COMMUNICATIONS...

  13. Use of Ni63 Overvoltage Gap Switches in the Flight Termination Systems on Boosters Launched from U.S. Army Kwajalein Atoll (USAKA)

    Science.gov (United States)

    1990-05-01

    COMMAND AGENCY: United States Army Strategic Defense Command. ACTION: Use of Ni63 Overvoltage Gap Switches in the Flight Termination Systems on Boosters...SOURCE OF FUNDING NUMBERS PROGRAM PROJECT TASK WORK UNIT ELEMENT NO. NO. NO. ACCESSION NO. I TITLE (Include Security Claification) Use of Ni63 ...U) 1 PERSONAL AUTHOR(S) Ni63 Environmental Assessment Team, Mr. Randy Gallien (Chairman) 1𔄁. TYPE OF REPORT 13b. TIME COVERED 14. DATE OF REPORT

  14. Fractional surface termination of diamond by electrochemical oxidation.

    Science.gov (United States)

    Hoffmann, René; Obloh, Harald; Tokuda, Norio; Yang, Nianjun; Nebel, Christoph E

    2012-01-10

    The crystalline form of sp(3)-hybridized carbon, diamond, offers various electrolyte-stable surface terminations. The H-termination-selective attachment of nitrophenyl diazonium, imaged by AFM, shows that electrochemical oxidation can control the fractional hydrogen/oxygen surface termination of diamond on the nanometer scale. This is of particular interest for all applications relying on interfacial electrochemistry, especially for biointerfaces.

  15. KAJIAN SANITASI TERMINAL DI PROVINSI DAERAH ISTIMEWA YOGYAKARTA TAHUN 2016

    Directory of Open Access Journals (Sweden)

    Dani Febriyanto

    2017-04-01

    Full Text Available Sanitasi adalah suatu usaha untuk mengawasi beberapa faktor lingkungan fisik yang berpenga-ruh pada manusia terutama terhadap hal-hal yang mempunyai efek merusak perkembangan fi-sik, kesehatan, dan kelangsungan hidup. Berdasarkan uji pendahuluan yang dilakukan pada 2-4 April 2016, diketahui bahwa terdapat beberapa sarana atau fasilitas terminal bus yang tidak se-suai dengan persyaratan. Hal tersebut memiliki dampak yang buruk bagi lingkungan dan kese-hatan manusia di tempat umum tersebut. Tujuan penelitian ini adalah untuk mengetahui gambar-an kondisi sanitasi terminal bus di Provinsi D. I. Yogyakarta, dengan melakukan penelitian survei dengan analisis deskriptif. Dari 16 populasi terminal yang ada, yang dijadikan sampel penelitian adalah Terminal Wates, Terminal Jombor, Terminal Giwangan, dan Terminal Dhaksinarga yang diambil dengan metoda area probability sampling. Ada lima variabel yang diamati dengan mela-kukan inspeksi sanitasi, yaitu: penyehatan lingkungan luar, penyehatan ruang dan bangunan, fa-silitas sanitasi, kenyamanan dan keselamatan, serta higiene makanan dan minuman. Hasil dan kesimpulan penelitian ini adalah kondisi sanitasi terminal bus di Provinsi D. I. Yogyakarta masih kurang baik, karena hanya Terminal Giwangan yang berkategori laik sehat dengan prosentase 89 %.

  16. Estrogen Receptor and Progesterone Receptor Expression in Normal Terminal Duct Lobular Units Surrounding Invasive Breast Cancer

    Science.gov (United States)

    Yang, Xiaohong R.; Figueroa, Jonine D.; Hewitt, Stephen M.; Falk, Roni T.; Pfeiffer, Ruth M.; Lissowska, Jolanta; Peplonska, Beata; Brinton, Louise A.; Garcia-Closas, Montserrat; Sherman, Mark E.

    2014-01-01

    Introduction Molecular and morphological alterations related to carcinogenesis have been found in terminal duct lobular units (TDLUs), the microscopic structures from which most breast cancer precursors and cancers develop, and therefore, analysis of these structures may reveal early changes in breast carcinogenesis and etiologic heterogeneity. Accordingly, we evaluated relationships of breast cancer risk factors and tumor pathology to estrogen receptor (ER) and progesterone receptor (PR) expression in TDLUs surrounding breast cancers. Methods We analyzed 270 breast cancer cases included in a population-based breast cancer case-control study conducted in Poland. TDLUs were mapped in relation to breast cancer: within the same block as the tumor (TDLU-T), proximal to tumor (TDLU-PT), or distant from (TDLU-DT). ER/PR was quantitated using image analysis of immunohistochemically stained TDLUs prepared as tissue microarrays. Results In surgical specimens containing ER-positive breast cancers, ER and PR levels were significantly higher in breast cancer cells than in normal TDLUs, and higher in TDLU-T than in TDLU-DT or TDLU-PT, which showed similar results. Analyses combining DT-/PT TDLUs within subjects demonstrated that ER levels were significantly lower in premenopausal women vs. postmenopausal women (odds ratio [OR]=0.38, 95% confidence interval [CI]=0.19, 0.76, P=0.0064) and among recent or current menopausal hormone therapy users compared with never users (OR=0.14, 95% CI=0.046–0.43, Ptrend=0.0006). Compared with premenopausal women, TDLUs of postmenopausal women showed lower levels of PR (OR=0.90, 95% CI=0.83–0.97, Ptrend=0.007). ER and PR expression in TDLUs was associated with epidermal growth factor receptor (EGFR) expression in invasive tumors (P=0.019 for ER and P=0.03 for PR), but not with other tumor features. Conclusions Our data suggest that TDLUs near breast cancers reflect field effects, whereas those at a distance demonstrate influences of breast

  17. X-ray crystal structure of the N-terminal region of Moloney murine leukemia virus integrase and its implications for viral DNA recognition: N-Terminal Region of M-MuLV Integrase

    Energy Technology Data Exchange (ETDEWEB)

    Guan, Rongjin [Center for Advanced Biotechnology and Medicine, Rutgers, The State University of New Jersey, Piscataway New Jersey 08854; Northeast Structural Genomics Consortium, Rutgers, The State University of New Jersey, Piscataway New Jersey 08854; Department of Molecular Biology and Biochemistry, Rutgers, The State University of New Jersey, Piscataway New Jersey 08854; Aiyer, Sriram [Department of Pharmacology, Robert Wood Johnson Medical School, Rutgers, The State University of New Jersey, Piscataway New Jersey 08854; Cote, Marie L. [Department of Biochemistry, Robert Wood Johnson Medical School, UMDNJ, Piscataway New Jersey 08854; Xiao, Rong [Center for Advanced Biotechnology and Medicine, Rutgers, The State University of New Jersey, Piscataway New Jersey 08854; Northeast Structural Genomics Consortium, Rutgers, The State University of New Jersey, Piscataway New Jersey 08854; Department of Molecular Biology and Biochemistry, Rutgers, The State University of New Jersey, Piscataway New Jersey 08854; Jiang, Mei [Center for Advanced Biotechnology and Medicine, Rutgers, The State University of New Jersey, Piscataway New Jersey 08854; Northeast Structural Genomics Consortium, Rutgers, The State University of New Jersey, Piscataway New Jersey 08854; Department of Molecular Biology and Biochemistry, Rutgers, The State University of New Jersey, Piscataway New Jersey 08854; Acton, Thomas B. [Center for Advanced Biotechnology and Medicine, Rutgers, The State University of New Jersey, Piscataway New Jersey 08854; Northeast Structural Genomics Consortium, Rutgers, The State University of New Jersey, Piscataway New Jersey 08854; Department of Molecular Biology and Biochemistry, Rutgers, The State University of New Jersey, Piscataway New Jersey 08854; Roth, Monica J. [Department of Pharmacology, Robert Wood Johnson Medical School, Rutgers, The State University of New Jersey, Piscataway New Jersey 08854; Montelione, Gaetano T. [Center for Advanced Biotechnology and Medicine, Rutgers, The State University of New Jersey, Piscataway New Jersey 08854; Northeast Structural Genomics Consortium, Rutgers, The State University of New Jersey, Piscataway New Jersey 08854; Department of Molecular Biology and Biochemistry, Rutgers, The State University of New Jersey, Piscataway New Jersey 08854; Department of Biochemistry, Robert Wood Johnson Medical School, UMDNJ, Piscataway New Jersey 08854

    2017-02-03

    The retroviral integrase (IN) carries out the integration of a dsDNA copy of the viral genome into the host DNA, an essential step for viral replication. All IN proteins have three general domains, the N-terminal domain (NTD), the catalytic core domain, and the C-terminal domain. The NTD includes an HHCC zinc finger-like motif, which is conserved in all retroviral IN proteins. Two crystal structures of Moloney murine leukemia virus (M-MuLV) IN N-terminal region (NTR) constructs that both include an N-terminal extension domain (NED, residues 1–44) and an HHCC zinc-finger NTD (residues 45–105), in two crystal forms are reported. The structures of IN NTR constructs encoding residues 1–105 (NTR1–105) and 8–105 (NTR8–105) were determined at 2.7 and 2.15 Å resolution, respectively and belong to different space groups. While both crystal forms have similar protomer structures, NTR1–105 packs as a dimer and NTR8–105 packs as a tetramer in the asymmetric unit. The structure of the NED consists of three anti-parallel β-strands and an α-helix, similar to the NED of prototype foamy virus (PFV) IN. These three β-strands form an extended β-sheet with another β-strand in the HHCC Zn2+ binding domain, which is a unique structural feature for the M-MuLV IN. The HHCC Zn2+ binding domain structure is similar to that in HIV and PFV INs, with variations within the loop regions. Differences between the PFV and MLV IN NEDs localize at regions identified to interact with the PFV LTR and are compared with established biochemical and virological data for M-MuLV. Proteins 2017; 85:647–656.

  18. The Integration of Women into Combat Units in the Republic of Korea Army

    Science.gov (United States)

    2014-12-12

    terminate their employment upon pregnancy because it was believed it made them “inadequate” for military service (which for them consisted of clerical...antiaircraft units. Most women are assigned to units defending fixed installations near their workplaces . Increasing numbers of women are being...less sexual discrimination in the military than in many other workplaces ,” an official of the Ministry of National Defense explained.48 However, the

  19. JCO criticality accident termination operation

    OpenAIRE

    金盛 正至

    2010-01-01

    In 2001, we summarized the circumstances surrounding termination of the JCO criticality accident based on testimony in the Mito District Court on December 17, 2001. JCO was the company for uranium fuels production in Japan. That document was assembled based on actual testimony in the belief that a description of the work involved in termination of the accident would be useful in some way for preventing nuclear disasters in the future. This year is the tenth year of the JCO criticality acciden...

  20. Community-level influences on women's experience of intimate partner violence and terminated pregnancy in Nigeria: a multilevel analysis

    Directory of Open Access Journals (Sweden)

    Antai Diddy

    2012-11-01

    Full Text Available Abstract Background Intimate partner violence (IPV is a major public health problem with serious consequences for women’s physical, mental, sexual and reproductive health. Reproductive health outcomes such as unwanted and terminated pregnancies, fetal loss or child loss during infancy, non-use of family planning methods, and high fertility are increasingly recognized. However, little is known about the role of community influences on women's experience of IPV and its effect on terminated pregnancy, given the increased awareness of IPV being a product of social context. This study sought to examine the role of community-level norms and characteristics in the association between IPV and terminated pregnancy in Nigeria. Methods Multilevel logistic regression analyses were performed on nationally-representative cross-sectional data including 19,226 women aged 15–49 years in Nigeria. Data were collected by a stratified two-stage sampling technique, with 888 primary sampling units (PSUs selected in the first sampling stage, and 7,864 households selected through probability sampling in the second sampling stage. Results Women who had experienced physical IPV, sexual IPV, and any IPV were more likely to have terminated a pregnancy compared to women who had not experienced these IPV types. IPV types were significantly associated with factors reflecting relationship control, relationship inequalities, and socio-demographic characteristics. Characteristics of the women aggregated at the community level (mean education, justifying wife beating, mean age at first marriage, and contraceptive use were significantly associated with IPV types and terminated pregnancy. Conclusion Findings indicate the role of community influence in the association between IPV-exposure and terminated pregnancy, and stress the need for screening women seeking abortions for a history of abuse.

  1. Introduction to Psychology and Leadership. Part Nine; Morale and Esprit De Corps. Content Outline, Terminal and Enabling Objectives.

    Science.gov (United States)

    Westinghouse Learning Corp., Annapolis, MD.

    The content is outlined and the terminal and enabling objectives are provided for a curriculum area on morale and esprit de corps (see EM 010 439, EM 010 440, and EM 010 461), part of an introduction to psychology and leadership course for the United States Naval Academy (see the final reports which summarize the course development project, EM 010…

  2. Training simulator for operations at LNG terminals

    International Nuclear Information System (INIS)

    Tsuta, T.; Yamamoto, K.; Tetsuka, S.; Koyama, K.

    1997-01-01

    The Tokyo Gas LNG terminals are among the major energy centers of the Tokyo area, supplying 8 million customers with city gas, and also supplying fuel for thermal power generation at the neighboring thermal power plant operated by the Tokyo Electric Power Company. For this reason, in the event of an emergency at the terminal operators have to be able to respond quickly and accurately to restore operations and prevent secondary damage. Modern LNG terminals are highly reliable and are equipped with backup systems, and occurrences of major trouble are now almost nil. Operators therefore have to be trained to respond to emergencies using simulators, in order to heighten their emergency response capabilities. Tokyo Gas Co., Ltd. has long been aware of the need for simulators and has used them in training, but a new large-scale, real-time simulator has now developed in response to new training needs, applying previously accumulated expertise to create a model of an entire LNG terminal incorporating new features. The development of this new simulator has made possible training for emergencies affecting an entire terminal, and this has been very effective in raising the standards of operators. (au)

  3. Terminal Disease: A Biolaw Management

    Directory of Open Access Journals (Sweden)

    Francisco Rivas García

    2017-10-01

    Full Text Available There are numerous and varied pathologies that can lead to a state of terminal illness, provoking numerous bioethical dilemmas that are inherent and specific to each circumstance. The objective of the present work has been to provide a current and useful analysis that can help to understand the main bioethical problems, from the perspective of biolaw that must be solved in the inevitable path towards the end of life that any terminal illness implies. The methodology used included a study of bibliographic documentation in the main databases of interest in bioethics. It can be concluded that the biolaw is a very useful tool that helps health care professionals and relatives when it comes to the analysis and decision making regarding a terminal illness. Independently of medical practice based on protocols and scientific knowledge, it is necessary to ensure that not everything that can legally be carried out is accepted in the field of biolaw.

  4. Thulema võlausaldajad kohtu armul / Anne Oja, Katariina Krjutškova ; kommenteerinud Jüri Ross

    Index Scriptorium Estoniae

    Oja, Anne, 1970-

    2010-01-01

    Thulema ei suutnud saneerimiskava täita, firma endise juhi Tarmo Priki hinnangul oleks kavaga välja vedanud, kui uued omanikud poleks müügipersonali rohkem kui poole võrra vähendanud. Firma võlakohustused on 30. aprilli seisuga 40,2 mln., varade väärtus 38,9 mln. krooni

  5. Micro-terminator: 'Hasta la vista, lncRNA!'.

    Science.gov (United States)

    Diederichs, Sven

    2015-04-01

    Transcriptional termination is an important yet incompletely understood aspect of gene expression. Proudfoot, Jopling and colleagues now identify a new Microprocessor-mediated mechanism of transcriptional termination, which acts specifically on long noncoding transcripts that serve as microRNA precursors.

  6. Predictable uncertainty about terminal operations in the sea

    Directory of Open Access Journals (Sweden)

    S. Hess

    2010-06-01

    Full Text Available This paper considers a problem of planning short term operations in a bulk terminal faced by port management when making tactical decisions. Ship loading and discharging, cargo stocking, the maintenance and service of facility equipment are regular operations of a bulk terminal which is a subsystem of a sea port the conduct of which is subject to difficult-to-predict or unforeseen influences. The problem that port management encounters in day to day operations looks into making the best possible plan with the scheduled duration of operations/states and transition instants, considering various internal and external factors influencing terminal performance. A state and transition model is used for deriving effective solutions to obtaining the state order and state transition time of a bulk terminal with an objective of minimizing operational costs. The behaviour of the terminal is tested applying the stochastic and deterministic method.

  7. Palliativ behandling af patienter med terminal kronisk obstruktiv lungesygdom

    DEFF Research Database (Denmark)

    von Plessen, Christian; Nielsen, Thyge L; Steffensen, Ida E

    2011-01-01

    Terminal chronic obstructive pulmonary disease (COPD) and advanced cancer have similar prognosis and symptom burden. However, palliative care of patients with terminal COPD has been neglected in Denmark. We describe the symptoms of terminal COPD and suggest criteria for defining the palliative...

  8. The Risk of Termination Shock From Solar Geoengineering

    Science.gov (United States)

    Parker, Andy; Irvine, Peter J.

    2018-03-01

    If solar geoengineering were to be deployed so as to mask a high level of global warming, and then stopped suddenly, there would be a rapid and damaging rise in temperatures. This effect is often referred to as termination shock, and it is an influential concept. Based on studies of its potential impacts, commentators often cite termination shock as one of the greatest risks of solar geoengineering. However, there has been little consideration of the likelihood of termination shock, so that conclusions about its risk are premature. This paper explores the physical characteristics of termination shock, then uses simple scenario analysis to plot out the pathways by which different driver events (such as terrorist attacks, natural disasters, or political action) could lead to termination. It then considers where timely policies could intervene to avert termination shock. We conclude that some relatively simple policies could protect a solar geoengineering system against most of the plausible drivers. If backup deployment hardware were maintained and if solar geoengineering were implemented by agreement among just a few powerful countries, then the system should be resilient against all but the most extreme catastrophes. If this analysis is correct, then termination shock should be much less likely, and therefore much less of a risk, than has previously been assumed. Much more sophisticated scenario analysis—going beyond simulations purely of worst-case scenarios—will be needed to allow for more insightful policy conclusions.

  9. Crystallization and preliminary X-ray crystallographic analysis of a 40 kDa N-terminal fragment of the yeast prion-remodeling factor Hsp104

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sukyeong; Tsai, Francis T. F., E-mail: ftsai@bcm.tmc.edu [Verna and Marrs McLean Department of Biochemistry and Molecular Biology, Baylor College of Medicine, Houston, TX 77030 (United States)

    2007-09-01

    An N-terminal fragment of S. cerevisiae Hsp104 has been crystallized. This is the first report of the crystallization of a eukaryotic member of the Hsp100 family of molecular chaperones. A 40 kDa N-terminal fragment of Saccharomyces cerevisiae Hsp104 was crystallized in two different crystal forms. Native 1 diffracted to 2.6 Å resolution and belonged to space group P2{sub 1}2{sub 1}2{sub 1}, with unit-cell parameters a = 66.6, b = 75.8, c = 235.7 Å. Native 2 diffracted to 2.9 Å resolution and belonged to space group P6{sub 1}22 or P6{sub 5}22, with unit-cell parameters a = 179.1, b = 179.1, c = 69.7 Å. This is the first report of the crystallization of a eukaryotic member of the Hsp100 family of molecular chaperones.

  10. Communication of technical information to lay audiences. [National Waste Terminal Storage (NWTS) program

    Energy Technology Data Exchange (ETDEWEB)

    Bowes, J.E.; Stamm, K.R.; Jackson, K.M.; Moore, J.

    1978-05-01

    One of the objectives of the National Waste Terminal Storage (NWTS) Program is to provide terminal storage facilities for commercial radioactive wastes in various geologic formations at multiple locations in the United States. The activities performed under the NWTS Program will affect regional, state, and local areas, and widespread public interest in this program is expected. Since a large part of the NWTS Program deals with technical information it was considered desirable to initiate a study dealing with possible methods of effectively transmitting this technical information to the general public. This study has the objective of preparing a state-of-the-art report on the communication of technical information to lay audiences. The particular task of communicating information about the NWTS Program to the public is discussed where appropriate. The results of this study will aid the NWTS Program in presenting to the public the quite diverse technical information generated within the program so that a widespread, thorough public understanding of the NWTS Program might be achieved. An annotated bibliography is included.

  11. 48 CFR 49.601 - Notice of termination for convenience.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 1 2010-10-01 2010-10-01 false Notice of termination for convenience. 49.601 Section 49.601 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION... termination for convenience. (See 49.402-3(g) for notice of termination for default.) ...

  12. 28 CFR 66.44 - Termination for convenience.

    Science.gov (United States)

    2010-07-01

    ... 28 Judicial Administration 2 2010-07-01 2010-07-01 false Termination for convenience. 66.44 Section 66.44 Judicial Administration DEPARTMENT OF JUSTICE (CONTINUED) UNIFORM ADMINISTRATIVE... Reports, Records, Retention, and Enforcement § 66.44 Termination for convenience. Except as provided in...

  13. Termination of Dynamic Contracts in an Equilibrium Labor Market Model

    OpenAIRE

    Wang, Cheng

    2005-01-01

    I construct an equilibrium model of the labor market where workers and firms enter into dyamic contracts that can potentially last forever, but are subject to optimal terminations. Upon a termination, the firm hires a new worker, and the worker who is terminated receives a termination compensation from the firm and is then free to go back to the labor market to seek new employment opportunities and enter into new dynamic contracts. The model permits only two types of equilibrium terminations ...

  14. Cloning, expression, purification, crystallization and preliminary X-ray studies of the C-terminal domain of Rv3262 (FbiB) from Mycobacterium tuberculosis

    International Nuclear Information System (INIS)

    Rehan, Aisyah M.; Bashiri, Ghader; Paterson, Neil G.; Baker, Edward N.; Squire, Christopher J.

    2011-01-01

    The C-terminal domain of FbiB, a bifunctional protein that is essential for the biosynthesis of cofactor F 420 in M. tuberculosis, has been expressed, purified and crystallized. The crystals diffracted to 2.0 Å resolution and were suitable for structure determination. During cofactor F 420 biosynthesis, the enzyme F 420 -γ-glutamyl ligase (FbiB) catalyzes the addition of γ-linked l-glutamate residues to form polyglutamylated F 420 derivatives. In Mycobacterium tuberculosis, Rv3262 (FbiB) consists of two domains: an N-terminal domain from the F 420 ligase superfamily and a C-terminal domain with sequence similarity to nitro-FMN reductase superfamily proteins. To characterize the role of the C-terminal domain of FbiB in polyglutamyl ligation, it has been purified and crystallized in an apo form. The crystals diffracted to 2.0 Å resolution using a synchrotron source and belonged to the tetragonal space group P4 1 2 1 2 (or P4 3 2 1 2), with unit-cell parameters a = b = 136.6, c = 101.7 Å, α = β = γ = 90°

  15. Aspectos éticos de la fase terminal Ethical aspects of terminal phase care

    Directory of Open Access Journals (Sweden)

    Oscar Velásquez

    1993-02-01

    Full Text Available

    Partiendo de una definición de la ética en general, de la ética médica y de la bioética, el autor discute estos conceptos en cuanto se relacionan con la atención del paciente en fase terminal, así como los temas de la muerte, el sufrimiento y los sentimientos que despierta el saberse moribundo. Hace énfasis en las relaciones médico-paciente y médico-familla y en los valores éticos de la igualdad y la reciprocidad. Plantea cómo a menudo el médico carece de una actitud correcta frente al paciente terminal y propone guías para el trabajo médico en tales circunstancias. Destaca la necesidad de respetar en todo momento la autonomía y la dignidad del enfermo y de saber usar con sabiduría los recursos tecnológicos disponibles.

     

    The author starts with definitions of ethics, medical ethics and bioethics and discusses their relationship with terminal patient care; also discussed are the subjects of death, suffering and the feelings that appear with the selfawareness of being near-death. Emphasis Is given on both patient-physician and family-physician relationships and on the values of equality and reciprocity. Guidelines are proposed for the approach and medical care of terminal patients and their families; they deal mainly with the need to respect autonomy and dignity and with the wise use of technological advances presently available.

     

  16. Assessing Port Governance, Devolution and Terminal Performance in Nigeria

    Directory of Open Access Journals (Sweden)

    D. E. Onwuegbuchunam

    2018-02-01

    Full Text Available Concerns about performance and efficiency in port terminals led many national governments to embark on port reforms. The Federal government of Nigeria, for example, adopted the Landlord port model which brought about concessioning of port terminals to private operators. Despite high investments in terminal facilities by the private terminal operators, there are still complaints about level of service offered to port users. This paper applied key performance indicator metrics and parameters of queuing model in assessing performance of Nigeria’s concessioned port terminals. Data for the study were obtained from terminal level records of cargo and ship handling activities for years 2000 to 2015. Major findings indicate that cargo and vessel throughputs improved after the reforms in the six ports examined. However, much variability was observed in trends in ships’ turnround times across all ports after the concession policy implementation. Additional results from the queuing model analysis suggest that the high ships turnround times observed in some ports are associated to delays in ship operation at the berths. The paper recommends that policy interventions be focused on ship operations at the berths as a step in improving service level in the port terminals.

  17. 45 CFR 2541.440 - Termination for convenience.

    Science.gov (United States)

    2010-10-01

    ... 45 Public Welfare 4 2010-10-01 2010-10-01 false Termination for convenience. 2541.440 Section 2541.440 Public Welfare Regulations Relating to Public Welfare (Continued) CORPORATION FOR NATIONAL AND... LOCAL GOVERNMENTS Reports, Records, Retention and Enforcement § 2541.440 Termination for convenience...

  18. 45 CFR 92.44 - Termination for convenience.

    Science.gov (United States)

    2010-10-01

    ... 45 Public Welfare 1 2010-10-01 2010-10-01 false Termination for convenience. 92.44 Section 92.44 Public Welfare DEPARTMENT OF HEALTH AND HUMAN SERVICES GENERAL ADMINISTRATION UNIFORM ADMINISTRATIVE... Requirements Reports, Records Retention, and Enforcement § 92.44 Termination for convenience. Except as...

  19. 14 CFR 1273.44 - Termination for convenience.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 5 2010-01-01 2010-01-01 false Termination for convenience. 1273.44 Section 1273.44 Aeronautics and Space NATIONAL AERONAUTICS AND SPACE ADMINISTRATION UNIFORM ADMINISTRATIVE... Reports, Records, Retention, and Enforcement § 1273.44 Termination for convenience. Except as provided in...

  20. 13 CFR 143.44 - Termination for convenience.

    Science.gov (United States)

    2010-01-01

    ... 13 Business Credit and Assistance 1 2010-01-01 2010-01-01 false Termination for convenience. 143.44 Section 143.44 Business Credit and Assistance SMALL BUSINESS ADMINISTRATION UNIFORM ADMINISTRATIVE... Reports, Records, Retention, and Enforcement § 143.44 Termination for convenience. Except as provided in...

  1. 29 CFR 4041.45 - Distress termination notice.

    Science.gov (United States)

    2010-07-01

    ..., Single-Employer Plan Termination, with Schedule EA-D, Distress Termination Enrolled Actuary Certification... guaranteed benefits. Unless the enrolled actuary certifies, in the Schedule EA-D filed in accordance with... benefits or benefit liabilities. If the enrolled actuary certifies that the plan is sufficient either for...

  2. 75 FR 49510 - Credit Watch Termination Initiative

    Science.gov (United States)

    2010-08-13

    ... DEPARTMENT OF HOUSING AND URBAN DEVELOPMENT [Docket No. FR-5411-N-02] Credit Watch Termination Initiative AGENCY: Office of the Assistant Secretary for Housing--Federal Housing Commissioner, HUD. ACTION... FHA Credit Watch Termination Initiative. This notice includes a list of mortgagees which have had...

  3. 75 FR 17944 - Credit Watch Termination Initiative

    Science.gov (United States)

    2010-04-08

    ... DEPARTMENT OF HOUSING AND URBAN DEVELOPMENT [Docket No. FR-5411-N-01] Credit Watch Termination Initiative AGENCY: Office of the Assistant Secretary for Housing--Federal Housing Commissioner, HUD. ACTION... FHA Credit Watch Termination Initiative. This notice includes a list of mortgagees which have had...

  4. What Determines Joint Venture Termination?

    DEFF Research Database (Denmark)

    Nielsen, Bo Bernhard

    2012-01-01

    Joint venture (JV) research continues to flourish as researchers seek to advance our understanding of why so many JVs fail. Cui and Kumar (this issue) take a contingency approach to explain how and why business relatedness may provide new insights as to what determines JV termination. This commen......Joint venture (JV) research continues to flourish as researchers seek to advance our understanding of why so many JVs fail. Cui and Kumar (this issue) take a contingency approach to explain how and why business relatedness may provide new insights as to what determines JV termination...

  5. Distinct termination morphologies for vertically aligned carbon nanotube forests

    International Nuclear Information System (INIS)

    Vinten, P; Marshall, P; Lefebvre, J; Finnie, P

    2010-01-01

    Vertically aligned carbon nanotube forests, including single-walled nanotubes, are imaged optically as they grow in situ from cobalt/alumina catalyst using water-assisted acetylene chemical vapor deposition. Three distinct termination morphologies are identified and investigated optically and via scanning electron microscopy. Quantitative growth dynamics are extracted and show gradual deceleration and sudden termination of growth. The termination morphology is discussed in terms of the balance of forces within the forest. We speculate that sudden termination is a collective effect arising from an imbalance in these forces.

  6. Antecedents and Consequences of Sales Representatives' Relationship Termination Competence

    DEFF Research Database (Denmark)

    Geersbro, Jens; Ritter, Thomas

    2013-01-01

    . In addition, termination competence significantly affects the value of customer portfolios. Practical implications: The findings suggest that managers should more actively consider relationship termination as a legitimate option in customer relationship management. In order to increase the value of a firm......'s customer portfolio, managers must not only provide a clear definition of the types of customers the organization does not want to serve, but must also implement termination routines within the organization. Managers also need to establish incentives for sales representatives to terminate relationships......Purpose: Most firms have a number of unprofitable customer relationships that drain the firms' resources. However, firms in general and sales representatives in particular hesitate to address this problem and, ultimately, to terminate business relationships. This paper therefore aims to investigate...

  7. Elamusturunduse mudel / Siiri Same

    Index Scriptorium Estoniae

    Same, Siiri

    2016-01-01

    Elamusturunduse kontseptuaalsest mudelist, mille järgi elamus on brändi/ettevõtte ja kliendi vahelise vastastikuse mõju ehk interaktsiooni tulemus. Mudeli teised olulised komponendid on turundustegevused, väärtuse koosloome ja tarbijakäitumine, millel koos elamusega on lõpptulemusena tähendus ja väärtus eri huvirühmade jaoks

  8. Kilekott kui kineskoop = Plastic Bag as Viewer / Johannes Saar

    Index Scriptorium Estoniae

    Saar, Johannes, 1965-

    2004-01-01

    Anu Järsi ja Kristi Kaljumäe kureeritud näitus "Kile kotti!" Eesti Rahva Muuseumis. Eksponeeriti 1980. aastatel Tartu Plastmasstoodete Katsetehases tehtud piltidega kilekotte, mälestusi kilekottide ümber keerelnud kultuurilisest tähendusest ja väärtusüsteemidest. Ameerikaliku massikultuuri, skandinaavia tarbimiskultuuri ja omarahvusluse ja -riikluse latentsed sümbolid

  9. Swedbank ei kavatse Hansapanka müüa

    Index Scriptorium Estoniae

    2008-01-01

    Maailma ühe suurima panga Citigroup analüütikute raporti järgi oleks Swedbanki panga väärtus palju suurem, kui panga mõned osad maha müüa. Hansapanga juhatuse esimehe Erkki Raasukese sõnul pole Swedbanki juhid rääkinud Hansapanga müügist, mis tähendaks panga strateegia muutmist

  10. Automatic termination of a protective action

    International Nuclear Information System (INIS)

    Heil, P.H.

    1986-01-01

    Subcommittee 6 of NPEC is responsible for the development of IEEE Standard 603. The adequacy of requirements concerning control and termination of protective actions was raised during the balloting of IEEE Standard 603-1980. In essence, the concern dealt with the requirement for deliberate operator action to return the system to normal. It was questioned if control actions such as automatic termination of system operation were allowed. Changes in the standard were made to clarify that there was a distinction between control (including termination) and return to normal and also state that automatic control may be required. Additionally, an action item was identified in the forward of IEEE Standard 603-1980 to determine if any additional changes were needed. The purpose of the paper is to present the results of this additional work

  11. Termination Criteria for Computerized Classification Testing

    Directory of Open Access Journals (Sweden)

    Nathan A. Thompson

    2011-02-01

    Full Text Available Computerized classification testing (CCT is an approach to designing tests with intelligent algorithms, similar to adaptive testing, but specifically designed for the purpose of classifying examinees into categories such as - pass- and - fail.- Like adaptive testing for point estimation of ability, the key component is the termination criterion, namely the algorithm that decides whether to classify the examinee and end the test or to continue and administer another item. This paper applies a newly suggested termination criterion, the generalized likelihood ratio (GLR, to CCT. It also explores the role of the indifference region in the specification of likelihood-ratio based termination criteria, comparing the GLR to the sequential probability ratio test. Results from simulation studies suggest that the GLR is always at least as efficient as existing methods.

  12. N-terminal nesprin-2 variants regulate β-catenin signalling

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Qiuping; Minaisah, Rose-Marie; Ferraro, Elisa; Li, Chen; Porter, Lauren J.; Zhou, Can; Gao, Fang; Zhang, Junyi; Rajgor, Dipen; Autore, Flavia; Shanahan, Catherine M.; Warren, Derek T., E-mail: derek.warren@kcl.ac.uk

    2016-07-15

    The spatial compartmentalisation of biochemical signalling pathways is essential for cell function. Nesprins are a multi-isomeric family of proteins that have emerged as signalling scaffolds, herein, we investigate the localisation and function of novel nesprin-2 N-terminal variants. We show that these nesprin-2 variants display cell specific distribution and reside in both the cytoplasm and nucleus. Immunofluorescence microscopy revealed that nesprin-2 N-terminal variants colocalised with β-catenin at cell-cell junctions in U2OS cells. Calcium switch assays demonstrated that nesprin-2 and β-catenin are lost from cell-cell junctions in low calcium conditions whereas emerin localisation at the NE remained unaltered, furthermore, an N-terminal fragment of nesprin-2 was sufficient for cell-cell junction localisation and interacted with β-catenin. Disruption of these N-terminal nesprin-2 variants, using siRNA depletion resulted in loss of β-catenin from cell-cell junctions, nuclear accumulation of active β-catenin and augmented β-catenin transcriptional activity. Importantly, we show that U2OS cells lack nesprin-2 giant, suggesting that the N-terminal nesprin-2 variants regulate β-catenin signalling independently of the NE. Together, these data identify N-terminal nesprin-2 variants as novel regulators of β-catenin signalling that tether β-catenin to cell-cell contacts to inhibit β-catenin transcriptional activity. - Highlights: • N-terminal nesprin-2 variants display cell specific expression patterns. • N-terminal spectrin repeats of nesprin-2 interact with β-catenin. • N-terminal nesprin-2 variants scaffold β-catenin at cell-cell junctions.. • Nesprin-2 variants play multiple roles in β-catenin signalling.

  13. Technical Efficiency Analysis of Container Terminals in the Middle Eastern Region

    Directory of Open Access Journals (Sweden)

    Ebrahim Sharaf Almawsheki

    2015-12-01

    Full Text Available Despite an increasing number of studies on the efficiency of container terminals, their focus has mostly been on advanced and emerging markets. There are limited studies on container terminals in developing countries such as those of the Middle Eastern region, which are located in a critical geographic position in the international maritime route between the East and the West. Information on their potential for development relative to other terminals worldwide is thus not readily available. This study aims to evaluate the technical efficiency of 19 container terminals in the Middle Eastern region. The DEA approach is used to measure technical efficiency, and slack variable analysis identifies potential areas of improvement for inefficient terminals. The results show that the Jebel Ali, Salalah and Beirut container terminals are the most efficient terminals in the region, and that the least efficient is the terminal in Aden. The results provide valuable information for terminal managers, helping to develop resource utilisation for steady development in operational efficiency.

  14. 20 CFR 437.44 - Termination for convenience.

    Science.gov (United States)

    2010-04-01

    ... 20 Employees' Benefits 2 2010-04-01 2010-04-01 false Termination for convenience. 437.44 Section 437.44 Employees' Benefits SOCIAL SECURITY ADMINISTRATION UNIFORM ADMINISTRATIVE REQUIREMENTS FOR..., Retention, and Enforcement § 437.44 Termination for convenience. Except as provided in § 437.43, awards may...

  15. 29 CFR 1470.44 - Termination for convenience.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 4 2010-07-01 2010-07-01 false Termination for convenience. 1470.44 Section 1470.44 Labor Regulations Relating to Labor (Continued) FEDERAL MEDIATION AND CONCILIATION SERVICE UNIFORM ADMINISTRATIVE... Reports, Records Retention, and Enforcement § 1470.44 Termination for convenience. Except as provided in...

  16. 28 CFR 73.5 - Termination of notification.

    Science.gov (United States)

    2010-07-01

    ... 28 Judicial Administration 2 2010-07-01 2010-07-01 false Termination of notification. 73.5 Section 73.5 Judicial Administration DEPARTMENT OF JUSTICE (CONTINUED) NOTIFICATIONS TO THE ATTORNEY GENERAL BY AGENTS OF FOREIGN GOVERNMENTS § 73.5 Termination of notification. (a) An agent shall, within 30...

  17. 5 CFR 837.202 - Annuities that terminate on reemployment.

    Science.gov (United States)

    2010-01-01

    ... 5 Administrative Personnel 2 2010-01-01 2010-01-01 false Annuities that terminate on reemployment... Annuities that terminate on reemployment. (a) FERS annuitants. (1) The annuity of a FERS annuitant who is a... terminates on reemployment. (2) The annuity of a FERS annuitant who is a former military reserve technician...

  18. Termination in cognitive-behavioral therapy with children, adolescents, and parents.

    Science.gov (United States)

    Vidair, Hilary B; Feyijinmi, Grace O; Feindler, Eva L

    2017-03-01

    The process of terminating cognitive-behavioral therapy (CBT) with families has been largely neglected in the literature, with the limited research focused on premature termination. This article describes the natural termination process in CBT with children, adolescents, and their parents. Based on existing theories, we describe a cognitive-behavioral model for: (a) initiating and engaging in discussion of termination, (b) processing the termination of treatment and the therapeutic relationship, (c) key aspects of the termination process in the final session, and (d) the very end of the final session (saying goodbye). For each of the 4 components, we review relevant theories, provide clinical exchanges to demonstrate techniques, and provide related research support. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  19. Altitudinal variations of ground tissue and xylem tissue in terminal shoot of woody species: implications for treeline formation.

    Science.gov (United States)

    Chen, Hong; Wang, Haiyang; Liu, Yanfang; Dong, Li

    2013-01-01

    1. The terminal shoot (or current-year shoot), as one of the most active parts on a woody plant, is a basic unit determining plant height and is potentially influenced by a variety of environmental factors. It has been predicted that tissues amount and their allocation in plant stems may play a critical role in determining plant size in alpine regions. The primary structure in terminal shoots is a key to our understanding treeline formation. The existing theories on treeline formation, however, are still largely lacking of evidence at the species level, much less from anatomy for the terminal shoot. 2. The primary structures within terminal shoot were measured quantitatively for 100 species from four elevation zones along the eastern slope of Gongga Mountain, southwestern China; one group was sampled from above the treeline. An allometric approach was employed to examine scaling relationships interspecifically, and a principal components analysis (PCA) was performed to test the relation among primary xylem, ground tissue, species growth form and altitude. 3. The results showed that xylem tissue size was closely correlated with ground tissue size isometrically across species, while undergoing significant y- or/and x-intercept shift in response to altitudinal belts. Further, a conspicuous characteristic of terminal shoot was its allocation of contrasting tissues between primary xylem and ground tissues with increasing elevation. The result of the PCA showed correlations between anatomical variation, species growth form/height classes and environment. 4. The current study presents a comparative assessment of the allocation of tissue in terminal shoot across phylogenically and ecologically diverse species, and analyzes tissue, function and climate associations with plant growth forms and height classes among species. The interspecific connection between primary xylem ratio and plant size along an elevation gradient suggests the importance of primary xylem in explaining

  20. Altitudinal variations of ground tissue and xylem tissue in terminal shoot of woody species: implications for treeline formation.

    Directory of Open Access Journals (Sweden)

    Hong Chen

    Full Text Available 1. The terminal shoot (or current-year shoot, as one of the most active parts on a woody plant, is a basic unit determining plant height and is potentially influenced by a variety of environmental factors. It has been predicted that tissues amount and their allocation in plant stems may play a critical role in determining plant size in alpine regions. The primary structure in terminal shoots is a key to our understanding treeline formation. The existing theories on treeline formation, however, are still largely lacking of evidence at the species level, much less from anatomy for the terminal shoot. 2. The primary structures within terminal shoot were measured quantitatively for 100 species from four elevation zones along the eastern slope of Gongga Mountain, southwestern China; one group was sampled from above the treeline. An allometric approach was employed to examine scaling relationships interspecifically, and a principal components analysis (PCA was performed to test the relation among primary xylem, ground tissue, species growth form and altitude. 3. The results showed that xylem tissue size was closely correlated with ground tissue size isometrically across species, while undergoing significant y- or/and x-intercept shift in response to altitudinal belts. Further, a conspicuous characteristic of terminal shoot was its allocation of contrasting tissues between primary xylem and ground tissues with increasing elevation. The result of the PCA showed correlations between anatomical variation, species growth form/height classes and environment. 4. The current study presents a comparative assessment of the allocation of tissue in terminal shoot across phylogenically and ecologically diverse species, and analyzes tissue, function and climate associations with plant growth forms and height classes among species. The interspecific connection between primary xylem ratio and plant size along an elevation gradient suggests the importance of primary

  1. High Octane Fuel: Terminal Backgrounder

    Energy Technology Data Exchange (ETDEWEB)

    Moriarty, Kristi [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2016-02-11

    The Bioenergy Technologies Office of the U.S. Department of Energy Office of Energy Efficiency and Renewable Energy sponsored a scoping study to assess the potential of ethanol-based high octane fuel (HOF) to reduce energy consumption and greenhouse gas emissions. When the HOF blend is made with 25%-40% ethanol by volume, this energy efficiency improvement is potentially sufficient to offset the reduced vehicle range often associated with the decreased volumetric energy density of ethanol. The purpose of this study is to assess the ability of the fuel supply chain to accommodate more ethanol at fuel terminals. Fuel terminals are midstream in the transportation fuel supply chain and serve to store and distribute fuels to end users. While there are no technical issues to storing more ethanol at fuel terminals, there are several factors that could impact the ability to deploy more ethanol. The most significant of these issues include the availability of land to add more infrastructure and accommodate more truck traffic for ethanol deliveries as well as a lengthy permitting process to erect more tanks.

  2. Terminated Multifamily Mortgages Database

    Data.gov (United States)

    Department of Housing and Urban Development — This dataset includes all terminated HUD Multifamily mortgages except those from the Hospital Mortgage Insurance Program. It includes the Holder and Servicer at the...

  3. Predicting transmission of structure-borne sound power from machines by including terminal cross-coupling

    DEFF Research Database (Denmark)

    Ohlrich, Mogens

    2011-01-01

    of translational terminals in a global plane. This paired or bi-coupled power transmission represents the simplest case of cross-coupling. The procedure and quality of the predicted transmission using this improved technique is demonstrated experimentally for an electrical motor unit with an integrated radial fan......Structure-borne sound generated by audible vibration of machines in vehicles, equipment and house-hold appliances is often a major cause of noise. Such vibration of complex machines is mostly determined and quantified by measurements. It has been found that characterization of the vibratory source...

  4. Diffractive optical elements for space communication terminals

    OpenAIRE

    Herzig, Hans-Peter; Ehbets, Peter; Teijido, Juan M.; Weible, Kenneth J.; Heimbeck, Hans-Joerg

    2007-01-01

    The potential of diffractive optical elements for advanced laser communication terminals has been investigated. Applications include beam shaping of high- power laser diode arrays, optical filter elements for position detection and hybrid (refractive/diffractive) elements. In addition, we present a design example of a miniaturized terminal including diffractive optics.

  5. 22 CFR 135.44 - Termination for convenience.

    Science.gov (United States)

    2010-04-01

    ... 22 Foreign Relations 1 2010-04-01 2010-04-01 false Termination for convenience. 135.44 Section 135.44 Foreign Relations DEPARTMENT OF STATE MISCELLANEOUS UNIFORM ADMINISTRATIVE REQUIREMENTS FOR GRANTS..., Retention, and Enforcement § 135.44 Termination for convenience. Except as provided in § 135.43 awards may...

  6. 15 CFR 24.44 - Termination for convenience.

    Science.gov (United States)

    2010-01-01

    ... 15 Commerce and Foreign Trade 1 2010-01-01 2010-01-01 false Termination for convenience. 24.44 Section 24.44 Commerce and Foreign Trade Office of the Secretary of Commerce UNIFORM ADMINISTRATIVE... Reports, Records, Retention, and Enforcement § 24.44 Termination for convenience. Except as provided in...

  7. 5 CFR 890.304 - Termination of enrollment.

    Science.gov (United States)

    2010-01-01

    ... is negative, the individual may request reconsideration of the decision from OPM. (3) If the... frame will be terminated. An annuitant whose enrollment is terminated because of failure to make an... conversion. (2) If the individual was prevented by circumstances beyond his or her control from making an...

  8. 28 CFR 55.7 - Termination of coverage.

    Science.gov (United States)

    2010-07-01

    ... VOTING RIGHTS ACT REGARDING LANGUAGE MINORITY GROUPS Nature of Coverage § 55.7 Termination of coverage. (a) Section 4(f)(4). A covered State, a political subdivision of a covered State, or a separately covered political subdivision may terminate the application of section 4(f)(4) by obtaining the...

  9. Modeling terminal ballistics using blending-type spline surfaces

    Science.gov (United States)

    Pedersen, Aleksander; Bratlie, Jostein; Dalmo, Rune

    2014-12-01

    We explore using GERBS, a blending-type spline construction, to represent deform able thin-plates and model terminal ballistics. Strategies to construct geometry for different scenarios of terminal ballistics are proposed.

  10. Structure of the C-terminal domain of lettuce necrotic yellows virus phosphoprotein.

    Science.gov (United States)

    Martinez, Nicolas; Ribeiro, Euripedes A; Leyrat, Cédric; Tarbouriech, Nicolas; Ruigrok, Rob W H; Jamin, Marc

    2013-09-01

    Lettuce necrotic yellows virus (LNYV) is a prototype of the plant-adapted cytorhabdoviruses. Through a meta-prediction of disorder, we localized a folded C-terminal domain in the amino acid sequence of its phosphoprotein. This domain consists of an autonomous folding unit that is monomeric in solution. Its structure, solved by X-ray crystallography, reveals a lollipop-shaped structure comprising five helices. The structure is different from that of the corresponding domains of other Rhabdoviridae, Filoviridae, and Paramyxovirinae; only the overall topology of the polypeptide chain seems to be conserved, suggesting that this domain evolved under weak selective pressure and varied in size by the acquisition or loss of functional modules.

  11. Agile service oriented shipping companies in the container terminal

    Directory of Open Access Journals (Sweden)

    W. Liu

    2009-06-01

    Full Text Available Agility is regarded as one of the core capabilities and the developing trend of supply chains and their enterprises. Along with the development of economical globalization, supply chain management and containerization as well as container ports as a part of supply chain take more roles like logistics or distribution centers. Under this background, the container terminal should have superior response and develop agility. The main goal of this paper is to emphasize and illustrate the importance and imminence of implementing agility in container terminals. To achieve this goal, the analysis of the economies of scale in the container terminal is presented. In this paper, however, more attention will be paid to agile service oriented shipping companies. The concept and characters of agile service in the container terminal is illustrated. The paper also focuses on the agile organizational structure of the container terminal. Finally, the fuzzy quality synthetic evaluation method is given to evaluate the performance level of agile service in container terminal oriented shipping companies.

  12. 34 CFR 80.44 - Termination for convenience.

    Science.gov (United States)

    2010-07-01

    ... 34 Education 1 2010-07-01 2010-07-01 false Termination for convenience. 80.44 Section 80.44 Education Office of the Secretary, Department of Education UNIFORM ADMINISTRATIVE REQUIREMENTS FOR GRANTS... Retention, and Enforcement § 80.44 Termination for convenience. Except as provided in § 80.43 awards may be...

  13. 40 CFR 31.44 - Termination for convenience.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 1 2010-07-01 2010-07-01 false Termination for convenience. 31.44 Section 31.44 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY GRANTS AND OTHER FEDERAL... convenience. Except as provided in § 31.43 awards may be terminated in whole or in part only as follows: (a...

  14. 45 CFR 1183.44 - Termination for convenience.

    Science.gov (United States)

    2010-10-01

    ... 45 Public Welfare 3 2010-10-01 2010-10-01 false Termination for convenience. 1183.44 Section 1183.44 Public Welfare Regulations Relating to Public Welfare (Continued) NATIONAL FOUNDATION ON THE ARTS..., Retention, and Enforcement § 1183.44 Termination for convenience. Except as provided in § 1183.43 awards may...

  15. 21 CFR 1403.44 - Termination for convenience.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 9 2010-04-01 2010-04-01 false Termination for convenience. 1403.44 Section 1403.44 Food and Drugs OFFICE OF NATIONAL DRUG CONTROL POLICY UNIFORM ADMINISTRATIVE REQUIREMENTS FOR..., Retention, and Enforcement § 1403.44 Termination for convenience. Except as provided in § 1403.43 awards may...

  16. 45 CFR 1174.44 - Termination for convenience.

    Science.gov (United States)

    2010-10-01

    ... 45 Public Welfare 3 2010-10-01 2010-10-01 false Termination for convenience. 1174.44 Section 1174.44 Public Welfare Regulations Relating to Public Welfare (Continued) NATIONAL FOUNDATION ON THE ARTS..., Retention, and Enforcement § 1174.44 Termination for convenience. Except as provided in § 1174.43 awards may...

  17. Applying the behavioral economics principle of unit price to DRO schedule thinning.

    Science.gov (United States)

    Roane, Henry S; Falcomata, Terry S; Fisher, Wayne W

    2007-01-01

    Within the context of behavioral economics, the ratio of response requirements to reinforcer magnitude is called unit price. In this investigation, we yoked increases in reinforcer magnitude with increases in intervals of differential reinforcement of other behavior (DRO) to thin DRO intervals to a terminal value.

  18. Three-Terminal Amorphous Silicon Solar Cells

    Directory of Open Access Journals (Sweden)

    Cheng-Hung Tai

    2011-01-01

    Full Text Available Many defects exist within amorphous silicon since it is not crystalline. This provides recombination centers, thus reducing the efficiency of a typical a-Si solar cell. A new structure is presented in this paper: a three-terminal a-Si solar cell. The new back-to-back p-i-n/n-i-p structure increased the average electric field in a solar cell. A typical a-Si p-i-n solar cell was also simulated for comparison using the same thickness and material parameters. The 0.28 μm-thick three-terminal a-Si solar cell achieved an efficiency of 11.4%, while the efficiency of a typical a-Si p-i-n solar cell was 9.0%. Furthermore, an efficiency of 11.7% was achieved by thickness optimization of the three-terminal solar cell.

  19. Termination of DNA replication forks: "Breaking up is hard to do".

    Science.gov (United States)

    Bailey, Rachael; Priego Moreno, Sara; Gambus, Agnieszka

    2015-01-01

    To ensure duplication of the entire genome, eukaryotic DNA replication initiates from thousands of replication origins. The replication forks move through the chromatin until they encounter forks from neighboring origins. During replication fork termination forks converge, the replisomes disassemble and topoisomerase II resolves the daughter DNA molecules. If not resolved efficiently, terminating forks result in genomic instability through the formation of pathogenic structures. Our recent findings shed light onto the mechanism of replisome disassembly upon replication fork termination. We have shown that termination-specific polyubiquitylation of the replicative helicase component - Mcm7, leads to dissolution of the active helicase in a process dependent on the p97/VCP/Cdc48 segregase. The inhibition of terminating helicase disassembly resulted in a replication termination defect. In this extended view we present hypothetical models of replication fork termination and discuss remaining and emerging questions in the DNA replication termination field.

  20. Emission inventory estimation of an intercity bus terminal.

    Science.gov (United States)

    Qiu, Zhaowen; Li, Xiaoxia; Hao, Yanzhao; Deng, Shunxi; Gao, H Oliver

    2016-06-01

    Intercity bus terminals are hotspots of air pollution due to concentrated activities of diesel buses. In order to evaluate the bus terminals' impact on air quality, it is necessary to estimate the associated mobile emission inventories. Since the vehicles' operating condition at the bus terminal varies significantly, conventional calculation of the emissions based on average emission factors suffers the loss of accuracy. In this study, we examined a typical intercity bus terminal-the Southern City Bus Station of Xi'an, China-using a multi-scale emission model-(US EPA's MOVES model)-to quantity the vehicle emission inventory. A representative operating cycle for buses within the station is constructed. The emission inventory was then estimated using detailed inputs including vehicle ages, operating speeds, operating schedules, and operating mode distribution, as well as meteorological data (temperature and humidity). Five functional areas (bus yard, platforms, disembarking area, bus travel routes within the station, and bus entrance/exit routes) at the terminal were identified, and the bus operation cycle was established using the micro-trip cycle construction method. Results of our case study showed that switching to compressed natural gas (CNG) from diesel fuel could reduce PM2.5 and CO emissions by 85.64 and 6.21 %, respectively, in the microenvironment of the bus terminal. When CNG is used, tail pipe exhaust PM2.5 emission is significantly reduced, even less than brake wear PM2.5. The estimated bus operating cycles can also offer researchers and policy makers important information for emission evaluation in the planning and design of any typical intercity bus terminals of a similar scale.