WorldWideScience

Sample records for term injection tests

  1. Injection Tests

    CERN Document Server

    Kain, V

    2009-01-01

    The success of the start-up of the LHC on 10th of September was in part due to the preparation without beam and injection tests in 2008. The injection tests allowed debugging and improvement in appropriate portions to allow safe, efficient and state-of-the-art commissioning later on. The usefulness of such an approach for a successful start-up becomes obvious when looking at the problems we encountered before and during the injection tests and could solve during this period. The outline of the preparation and highlights of the different injection tests will be presented and the excellent performance of many tools discussed. A list of shortcomings will follow, leading to some planning for the preparation of the run in 2009.

  2. Permeability of fissured rock - an experimental study with special regard to the water injection test

    International Nuclear Information System (INIS)

    Schneider, H.J.

    1987-01-01

    The permeability to water of fissured rock is one of the most important design parameters for many underground projects, such as, e.g. the final deposition of radioactive waste. Because the conventional water injection test according to LUGEON for the calculation of permeability to water is associated with a high degree of uncertainty, new test equipment was developed. This equipment works on the principle of the water injection tracer test and multi-level measurements, enabling detailed measurement of the flow process at injection site and in the rock. The tests were carried out in Bunter sandstone and granite. The LUGEON test concept was varied in short-term and long-term tests at identical geological boundary conditions, and with test control at constant pressure on the one hand and at constant injection volume on the other. The test results show that non-steady-state flow occurs with short injection times, whereby the range is limited to the local rock at injection site. An increasing in injection time can lead to an increase in range by a number of factors as well as to steady-state flow conditions. The permeability of the rock types investigated is inhomgeneous and anistropic as a result of the fissured structure. (orig./HP) With 114 figs., 4 tabs [de

  3. Anisomycin Injection in Area CA3 of the Hippocampus Impairs Both Short-Term and Long-Term Memories of Contextual Fear

    Science.gov (United States)

    Remaud, Jessica; Ceccom, Johnatan; Carponcy, Julien; Dugué, Laura; Menchon, Gregory; Pech, Stéphane; Halley, Helene; Francés, Bernard; Dahan, Lionel

    2014-01-01

    Protein synthesis is involved in the consolidation of short-term memory into long-term memory. Previous electrophysiological data concerning LTP in CA3 suggest that protein synthesis in that region might also be necessary for short-term memory. We tested this hypothesis by locally injecting the protein synthesis inhibitor anisomycin in hippocampal…

  4. Long-Term Carbon Injection Field Test for 90% Mercury Removal for a PRB Unit a Spray Dryer and Fabric Filter

    Energy Technology Data Exchange (ETDEWEB)

    Sjostrom, Sharon; Amrhein, Jerry

    2009-04-30

    The power industry in the U.S. is faced with meeting regulations to reduce the emissions of mercury compounds from coal-fired plants. Injecting a sorbent such as powdered activated carbon (PAC) into the flue gas represents one of the simplest and most mature approaches to controlling mercury emissions from coal-fired boilers. The purpose of this test program was to evaluate the long-term mercury removal capability, long-term mercury emissions variability, and operating and maintenance (O&M) costs associated with sorbent injection on a configuration being considered for many new plants. Testing was conducted by ADA Environmental Solutions (ADA) at Rocky Mountain Power’s (RMP) Hardin Station through funding provided by DOE/NETL, RMP, and other industry partners. The Hardin Station is a new plant rated at 121 MW gross that was first brought online in April of 2006. Hardin fires a Powder River Basin (PRB) coal and is configured with selective catalytic reduction (SCR) for NOx control, a spray dryer absorber (SDA) for SO2 control, and a fabric filter (FF) for particulate control. Based upon previous testing at PRB sites with SCRs, very little additional mercury oxidation from the SCR was expected at Hardin. In addition, based upon results from DOE/NETL Phase II Round I testing at Holcomb Station and results from similarly configured sites, low native mercury removal was expected across the SDA and FF. The main goal of this project was met—sorbent injection was used to economically and effectively achieve 90% mercury control as measured from the air heater (AH) outlet to the stack for a period of ten months. This goal was achieved with DARCO® Hg-LH, Calgon FLUEPAC®-MC PLUS and ADA Power PAC PREMIUM brominated activated carbons at nominal loadings of 1.5–2.5 lb/MMacf. An economic analysis determined the twenty-year levelized cost to be 0.87 mills/kW-hr, or $15,000/lb Hg removed. No detrimental effects on other equipment or plant operations were observed. The

  5. Large scale gas injection test (Lasgit): Results from two gas injection tests

    International Nuclear Information System (INIS)

    Cuss, R. J.; Harrington, J. F.; Noy, D. J.; Wikman, A.; Sellin, P.

    2011-01-01

    This paper describes the initial results from a large scale gas injection test (Lasgit) performed at the Aespoe Hard Rock Laboratory (Sweden)). Lasgit is a full-scale field-scale experiment based on the Swedish KBS-3V repository concept, examining the processes controlling gas and water flow in compact buffer bentonite. The first 2 years of the test focused on the artificial hydration of the bentonite buffer. This was followed by a programme of hydraulic and gas injection tests which ran from day 843 to 1110. A further period of artificial hydration occurred from day 1110 to 1385, followed by a more complex programme of gas injection testing which remains on going (day 1385+). After 2 years of hydration, hydraulic conductivity and specific storage values in the lower filter array were found to range from 9 x 10 -14 to 1.6 x 10 -13 m/s and 5.5 x 10 -5 to 4.4 x 10 -4 m -1 respectively, with the injection filter FL903 yielding values of 7.5 x 10 -14 m/s and 2.5 x 10 -5 m -1 . A second set of hydraulic measurements were performed over 1 year and a half later yielding similar values, in the range 7.8 x 10 -14 m/s and 1.3 x 10 -13 m/s. The hydraulic conductivity of FL903 had reduced slightly to 5.3 x 10 -14 m/s while specific storage had increased to 4.0 x 10 -5 m -1 . Both datasets agree with laboratory values performed on small-scale saturated samples. Two sets of gas injection tests were performed over a 3 year period. During the course of testing, gas entry pressure was found to increase from around 650 kPa to approximately 1.3 MPa, indicative of the maturation of the clay. The sequential reduction in volumetric flow rate and lack of correlation between the rate of gas inflow and the gas pressure gradient observed during constant pressure steps prior to major gas entry, is suggestive of a reduction in gas permeability of the buffer and indicates only limited quantities of gas can be injected into the clay without interacting with the continuum stress field. Major gas

  6. Treatability Test Plan for 300 Area Uranium Stabilization through Polyphosphate Injection

    International Nuclear Information System (INIS)

    Vermeul, Vince R.; Williams, M. D.; Fritz, Brad G.; Mackley, Rob D.; Mendoza, Donaldo P.; Newcomer, Darrell R.; Rockhold, Mark L.; Williams, Bruce A.; Wellman, Dawn M.

    2007-01-01

    The U.S. Department of Energy has initiated a study into possible options for stabilizing uranium at the 300 Area using polyphosphate injection. As part of this effort, PNNL will perform bench- and field-scale treatability testing designed to evaluate the efficacy of using polyphosphate injections to reduced uranium concentrations in the groundwater to meet drinking water standards (30 (micro)g/L) in situ. This technology works by forming phosphate minerals (autunite and apatite) in the aquifer that directly sequester the existing aqueous uranium in autunite minerals and precipitates apatite minerals for sorption and long term treatment of uranium migrating into the treatment zone, thus reducing current and future aqueous uranium concentrations. Polyphosphate injection was selected for testing based on technology screening as part of the 300-FF-5 Phase III Feasibility Study for treatment of uranium in the 300-Area

  7. Treatability Test Plan for 300 Area Uranium Stabilization through Polyphosphate Injection

    Energy Technology Data Exchange (ETDEWEB)

    Vermeul, Vincent R.; Williams, Mark D.; Fritz, Brad G.; Mackley, Rob D.; Mendoza, Donaldo P.; Newcomer, Darrell R.; Rockhold, Mark L.; Williams, Bruce A.; Wellman, Dawn M.

    2007-06-01

    The U.S. Department of Energy has initiated a study into possible options for stabilizing uranium at the 300 Area using polyphosphate injection. As part of this effort, PNNL will perform bench- and field-scale treatability testing designed to evaluate the efficacy of using polyphosphate injections to reduced uranium concentrations in the groundwater to meet drinking water standards (30 ug/L) in situ. This technology works by forming phosphate minerals (autunite and apatite) in the aquifer that directly sequester the existing aqueous uranium in autunite minerals and precipitates apatite minerals for sorption and long term treatment of uranium migrating into the treatment zone, thus reducing current and future aqueous uranium concentrations. Polyphosphate injection was selected for testing based on technology screening as part of the 300-FF-5 Phase III Feasibility Study for treatment of uranium in the 300-Area.

  8. The impact of interpreted flow regimes during constant head injection tests on the estimated transmissivity from injection tests and difference flow logging

    Energy Technology Data Exchange (ETDEWEB)

    Hjerne, Calle; Ludvigsson, Jan-Erik; Harrstroem, Johan [Geosigma AB, Uppsala (Sweden)

    2013-04-15

    A large number of constant head injection tests were carried out in the site investigation at Forsmark using the Pipe String System, PSS3. During the original evaluation of the tests the dominating transient flow regimes during both the injection and recovery period were interpreted together with estimation of hydraulic parameters. The flow regimes represent different flow and boundary conditions during the tests. Different boreholes or borehole intervals may display different distributions of flow regimes. In some boreholes good agreement was obtained between the results of the injection tests and difference flow logging with Posiva flow log (PFL) but in other boreholes significant discrepancies were found. The main objective of this project is to study the correlation between transient flow regimes from the injection tests and other borehole features such as transmissivity, depth, geology, fracturing etc. Another subject studied is whether observed discrepancies between estimated transmissivity from difference flow logging and injection tests can be correlated to interpreted flow regimes. Finally, a detailed comparison between transient and stationary evaluation of transmissivity from the injection tests in relation to estimated transmissivity from PFL tests in corresponding sections is made. Results from previous injection tests in 5 m sections in boreholes KFM04, KFM08A and KFM10A were used. Only injection tests above the (test-specific) measurement limit regarding flow rate are included in the analyses. For all of these tests transient flow regimes were interpreted. In addition, results from difference flow logging in the corresponding 5 m test sections were used. Finally, geological data of fractures together with rock and fracture zone properties have been used in the correlations. Flow regimes interpreted from the injection period of the tests are generally used in the correlations but deviations between the interpreted flow regimes from the injection and

  9. In Situ Decommissioning Sensor Network, Meso-Scale Test Bed - Phase 3 Fluid Injection Test Summary Report

    International Nuclear Information System (INIS)

    Serrato, M. G.

    2013-01-01

    The DOE Office of Environmental management (DOE EM) faces the challenge of decommissioning thousands of excess nuclear facilities, many of which are highly contaminated. A number of these excess facilities are massive and robust concrete structures that are suitable for isolating the contained contamination for hundreds of years, and a permanent decommissioning end state option for these facilities is in situ decommissioning (ISD). The ISD option is feasible for a limited, but meaningfull number of DOE contaminated facilities for which there is substantial incremental environmental, safety, and cost benefits versus alternate actions to demolish and excavate the entire facility and transport the rubble to a radioactive waste landfill. A general description of an ISD project encompasses an entombed facility; in some cases limited to the blow-grade portion of a facility. However, monitoring of the ISD structures is needed to demonstrate that the building retains its structural integrity and the contaminants remain entombed within the grout stabilization matrix. The DOE EM Office of Deactivation and Decommissioning and Facility Engineering (EM-13) Program Goal is to develop a monitoring system to demonstrate long-term performance of closed nuclear facilities using the ISD approach. The Savannah River National Laboratory (SRNL) has designed and implemented the In Situ Decommissioning Sensor Network, Meso-Scale Test Bed (ISDSN-MSTB) to address the feasibility of deploying a long-term monitoring system into an ISD closed nuclear facility. The ISDSN-MSTB goal is to demonstrate the feasibility of installing and operating a remote sensor network to assess cementitious material durability, moisture-fluid flow through the cementitious material, and resulting transport potential for contaminate mobility in a decommissioned closed nuclear facility. The original ISDSN-MSTB installation and remote sensor network operation was demonstrated in FY 2011-12 at the ISDSN-MSTB test cube

  10. In Situ Decommissioning Sensor Network, Meso-Scale Test Bed - Phase 3 Fluid Injection Test Summary Report

    Energy Technology Data Exchange (ETDEWEB)

    Serrato, M. G.

    2013-09-27

    The DOE Office of Environmental management (DOE EM) faces the challenge of decommissioning thousands of excess nuclear facilities, many of which are highly contaminated. A number of these excess facilities are massive and robust concrete structures that are suitable for isolating the contained contamination for hundreds of years, and a permanent decommissioning end state option for these facilities is in situ decommissioning (ISD). The ISD option is feasible for a limited, but meaningfull number of DOE contaminated facilities for which there is substantial incremental environmental, safety, and cost benefits versus alternate actions to demolish and excavate the entire facility and transport the rubble to a radioactive waste landfill. A general description of an ISD project encompasses an entombed facility; in some cases limited to the blow-grade portion of a facility. However, monitoring of the ISD structures is needed to demonstrate that the building retains its structural integrity and the contaminants remain entombed within the grout stabilization matrix. The DOE EM Office of Deactivation and Decommissioning and Facility Engineering (EM-13) Program Goal is to develop a monitoring system to demonstrate long-term performance of closed nuclear facilities using the ISD approach. The Savannah River National Laboratory (SRNL) has designed and implemented the In Situ Decommissioning Sensor Network, Meso-Scale Test Bed (ISDSN-MSTB) to address the feasibility of deploying a long-term monitoring system into an ISD closed nuclear facility. The ISDSN-MSTB goal is to demonstrate the feasibility of installing and operating a remote sensor network to assess cementitious material durability, moisture-fluid flow through the cementitious material, and resulting transport potential for contaminate mobility in a decommissioned closed nuclear facility. The original ISDSN-MSTB installation and remote sensor network operation was demonstrated in FY 2011-12 at the ISDSN-MSTB test cube

  11. Large scale injection test (LASGIT) modelling

    International Nuclear Information System (INIS)

    Arnedo, D.; Olivella, S.; Alonso, E.E.

    2010-01-01

    Document available in extended abstract form only. With the objective of understanding the gas flow processes through clay barriers in schemes of radioactive waste disposal, the Lasgit in situ experiment was planned and is currently in progress. The modelling of the experiment will permit to better understand of the responses, to confirm hypothesis of mechanisms and processes and to learn in order to design future experiments. The experiment and modelling activities are included in the project FORGE (FP7). The in situ large scale injection test Lasgit is currently being performed at the Aespoe Hard Rock Laboratory by SKB and BGS. An schematic layout of the test is shown. The deposition hole follows the KBS3 scheme. A copper canister is installed in the axe of the deposition hole, surrounded by blocks of highly compacted MX-80 bentonite. A concrete plug is placed at the top of the buffer. A metallic lid anchored to the surrounding host rock is included in order to prevent vertical movements of the whole system during gas injection stages (high gas injection pressures are expected to be reached). Hydration of the buffer material is achieved by injecting water through filter mats, two placed at the rock walls and two at the interfaces between bentonite blocks. Water is also injected through the 12 canister filters. Gas injection stages are performed injecting gas to some of the canister injection filters. Since the water pressure and the stresses (swelling pressure development) will be high during gas injection, it is necessary to inject at high gas pressures. This implies mechanical couplings as gas penetrates after the gas entry pressure is achieved and may produce deformations which in turn lead to permeability increments. A 3D hydro-mechanical numerical model of the test using CODE-BRIGHT is presented. The domain considered for the modelling is shown. The materials considered in the simulation are the MX-80 bentonite blocks (cylinders and rings), the concrete plug

  12. Small-scale bentonite injection test on rock

    International Nuclear Information System (INIS)

    Pusch, R.

    1978-03-01

    When radiactive waste is disposed a sealing of the rock is very valuable since it reduces the rate of water percolation and diffusion. In an earlier report injection of bentonite gels by means of over-pressure and subsequent electrophoresis has been suggested. The present report describes a rock test series where bentonite injection was applied. For the test an approximately cubical block of about 1 m 3 was selected. The rock type was diorite with a fairly high frequency of quartz denses. The block was kept in a basin during the test in order to maintain the water saturation. Holes were bored in the block. A bentonite slurry with 1000 percent water content was injected. It was shown that the bentonite had a sealing effect but the depth of extrusion into rock joints was not large because of gelation. Electro-Kinetic injection of montmorillonite was found to be a more promising technique for rock lightening

  13. Injecting Errors for Testing Built-In Test Software

    Science.gov (United States)

    Gender, Thomas K.; Chow, James

    2010-01-01

    Two algorithms have been conceived to enable automated, thorough testing of Built-in test (BIT) software. The first algorithm applies to BIT routines that define pass/fail criteria based on values of data read from such hardware devices as memories, input ports, or registers. This algorithm simulates effects of errors in a device under test by (1) intercepting data from the device and (2) performing AND operations between the data and the data mask specific to the device. This operation yields values not expected by the BIT routine. This algorithm entails very small, permanent instrumentation of the software under test (SUT) for performing the AND operations. The second algorithm applies to BIT programs that provide services to users application programs via commands or callable interfaces and requires a capability for test-driver software to read and write the memory used in execution of the SUT. This algorithm identifies all SUT code execution addresses where errors are to be injected, then temporarily replaces the code at those addresses with small test code sequences to inject latent severe errors, then determines whether, as desired, the SUT detects the errors and recovers

  14. Long-term follow-up of high-pressure injection injuries to the hand

    NARCIS (Netherlands)

    Wieder, Anat; Lapid, Oren; Plakht, Ygal; Sagi, Amiram

    2006-01-01

    High-pressure injection injury is an injury caused by accidental injection of substances by industrial equipment. This injury may have devastating sequelae. The goal of this study was to assess the long-term outcome of high-pressure injection injury to the hand. In this historical prospective study,

  15. Laryngeal electromyography-guided hyaluronic acid vocal fold injection for unilateral vocal fold paralysis: a prospective long-term follow-up outcome report.

    Science.gov (United States)

    Wang, Chen-Chi; Chang, Ming-Hong; Jiang, Rong-San; Lai, Hsiu-Chin; De Virgilio, Armando; Wang, Ching-Ping; Wu, Shang-Heng; Liu, Shi-An; Liang, Kai-Li

    2015-03-01

    Unilateral vocal fold paralysis (UVFP) is a common voice disorder that may cause glottal closure insufficiency with hoarseness of voice. Laryngeal electromyography (LEMG)-guided hyaluronic acid vocal fold (VF) injection has been proposed as a treatment option to improve glottal closure with a satisfactory short-term effect. To our knowledge, this study reports the first long-term follow-up result of this treatment modality. To present the long-term treatment results of LEMG-guided hyaluronic acid VF injection for UVFP. Prospective study of the treatment results of 74 patients who received LEMG-guided hyaluronic acid VF injection for UVFP at a tertiary referral medical center from March 2010 to February 2013. In the office-based procedure, 1.0 mL of hyaluronic acid was injected via a 26-gauge monopolar injectable needle electrode into paralyzed thyroarytenoid muscles by LEMG guidance. Various glottal closure evaluations such as normalized glottal gap area, maximal phonation time, phonation quotient, mean airflow rate, perceptual GRBAS (grade, roughness, breathiness, asthenia, strain) scale, and Voice Handicap Index were compared before and after injection using the nonparametric Wilcoxon signed rank test within 1 month, at 6 months, and at the last follow-up examination. Sixty patients had been followed up for at least 6 months. Forty-four patients received only 1 injection, and 16 patients received repeated injections (2 injections for 13 patients and 3 for 3 patients). All the glottal closure parameters improved significantly (P injection and 16 (22%) who received repeated injections did not require another treatment after long-term follow-up. Laryngeal electromyography-guided hyaluronic acid VF injection is an option for treating UVFP with satisfactory results.

  16. Experiment data report for Semiscale Mod-1 Test S-05-3 (alternate ECC injection test)

    International Nuclear Information System (INIS)

    Feldman, E.M.; Patton, M.L. Jr.; Sackett, K.E.

    1977-03-01

    Recorded test data are presented for Test S-05-3 of the Semiscale Mod-1 alternate ECC injection test series. These tests are among several Semiscale Mod-1 experiments conducted to investigate the thermal and hydraulic phenomena accompanying a hypothesized loss-of-coolant accident in a pressurized water reactor (PWR) system. Test S-05-3 was conducted from initial conditions of 2263 psia and 545 0 F to investigate the response of the Semiscale Mod-1 system to a depressurization and reflood transient following a simulated double-ended offset shear of the cold leg broken loop piping. During the test, cooling water was injected into the cold leg sides of the intact and broken loops and into the vessel upper plenum to simulate emergency core coolant injection in a PWR. For Test S-05-3, specifically the effects of upper plenum coolant injection on core thermal and system response were being investigated

  17. Experiment data report for Semiscale Mod-1 Test S-05-4 (alternate ECC injection test)

    International Nuclear Information System (INIS)

    Collins, B.L.; Feldman, E.M.

    1977-03-01

    Recorded test data are presented for Test S-05-4 of the Semiscale Mod-1 alternate emergency core coolant injection test series. These tests are among several Semiscale Mod-1 experiments conducted to investigate the thermal and hydraulic phenomena accompanying a hypothesized loss-of-coolant accident in a pressurized water reactor (PWR) system. Test S-05-4 was conducted from initial conditions of 2266 psia and 543 0 F to investigate the response of the Semiscale Mod-1 system to a depressurization and reflood transient following a simulated double-ended offset shear of the cold leg broken loop piping. During the test, cooling water was injected into the cold leg of each loop and into the vessel upper plenum to simulate emergency core coolant injection in a PWR. The upper plenum coolant injection was scaled according to the heat stored in the metal mass of the upper plenum

  18. Automatic estimation of aquifer parameters using long-term water supply pumping and injection records

    Science.gov (United States)

    Luo, Ning; Illman, Walter A.

    2016-09-01

    Analyses are presented of long-term hydrographs perturbed by variable pumping/injection events in a confined aquifer at a municipal water-supply well field in the Region of Waterloo, Ontario (Canada). Such records are typically not considered for aquifer test analysis. Here, the water-level variations are fingerprinted to pumping/injection rate changes using the Theis model implemented in the WELLS code coupled with PEST. Analyses of these records yield a set of transmissivity ( T) and storativity ( S) estimates between each monitoring and production borehole. These individual estimates are found to poorly predict water-level variations at nearby monitoring boreholes not used in the calibration effort. On the other hand, the geometric means of the individual T and S estimates are similar to those obtained from previous pumping tests conducted at the same site and adequately predict water-level variations in other boreholes. The analyses reveal that long-term municipal water-level records are amenable to analyses using a simple analytical solution to estimate aquifer parameters. However, uniform parameters estimated with analytical solutions should be considered as first rough estimates. More accurate hydraulic parameters should be obtained by calibrating a three-dimensional numerical model that rigorously captures the complexities of the site with these data.

  19. The value of short-term pain relief in predicting the long-term outcome of 'indirect' cervical epidural steroid injections.

    Science.gov (United States)

    Joswig, Holger; Neff, Armin; Ruppert, Christina; Hildebrandt, Gerhard; Stienen, Martin Nikolaus

    2018-05-01

    The predictive value of short-term arm pain relief after 'indirect' cervical epidural steroid injection (ESI) for the 1-month treatment response has been previously demonstrated. It remained to be answered whether the long-term response could be estimated by the early post-interventional pain course as well. Prospective observational study, following a cohort of n = 45 patients for a period of 24 months after 'indirect' ESI for radiculopathy secondary to a single-level cervical disk herniation (CDH). Arm and neck pain on the visual analog scale (VAS), health-related quality of life with the Short Form-12 (SF-12), and functional outcome with the Neck Pain and Disability (NPAD) Scale were assessed. Any additional invasive treatment after a single injection (second injection or surgery) defined treatment outcome as 'non-response'. At 24 months, n = 30 (66.7%) patients were responders and n = 15 (33.3%) were non-responders. Non-responders exited the follow-up at 1 month (n = 10), at 3 months (n = 4), and at 6 months (n = 1). No patients were injected again or operated on between the 6- and 24-month follow-up. Patients with favorable treatment response at 24 months had significantly lower VAS arm pain (p  50% short term pain reduction was not a reliable predictor of the 24-month responder status. SF-12 and NPAD scores were better among treatment responders in the long term. Patients who require a second injection or surgery after 'indirect' cervical ESI for a symptomatic CDH do so within the first 6 months. Short-term pain relief cannot reliably predict the long-term outcome.

  20. Experiment data report for Semiscale Mod-1 Test S-05-1 (alternate ECC injection test)

    International Nuclear Information System (INIS)

    Feldman, E.M.; Patton, M.L. Jr.; Sackett, K.E.

    1977-02-01

    Recorded test data are presented for Test S-05-1 of the Semiscale Mod-1 alternate ECC injection test series. These tests are among several Semiscale Mod-1 experiments conducted to investigate the thermal and hydraulic phenomena accompanying a hypothesized loss-of-coolant accident in a pressurized water reactor (PWR) system. Test S-05-1 was conducted from initial conditions of 2263 psia and 544 0 F to investigate the response of the Semiscale Mod-1 system to a depressurization and reflood transient following a simulated double-ended offset shear of the cold leg broken loop piping. During the test, cooling water was injected into the vessel lower plenum to simulate emergency core coolant injection in a PWR, with the flow rate based on system volume scaling

  1. Fluoroscopically guided caudal epidural steroid injection for management of degenerative lumbar spinal stenosis: short-term and long-term results

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Joon Woo; Myung, Jae Sung; Kang, Heung Sik [Seoul National University Bundang Hospital, Department of Radiology, Seong Nam, Gyeongi-do (Korea); Park, Kun Woo; Yeom, Jin S. [Seoul National University Bundang Hospital, Department of Orthopaedic Surgery, Seong Nam, Gyeongi-do (Korea); Kim, Ki-Jeong; Kim, Hyun-Jib [Seoul National University Bundang Hospital, Department of Neurosurgery, Seong Nam, Gyeongi-do (Korea)

    2010-07-15

    To evaluate the short-term and long-term effects of fluoroscopically guided caudal epidural steroid injection (ESI) for the management of degenerative lumbar spinal stenosis (DLSS) and to analyze outcome predictors. All patients who underwent caudal ESI in 2006 for DLSS were included in the study. Response was based on chart documentation (aggravated, no change, slightly improved, much improved, no pain). In June 2009 telephone interviews were conducted, using formatted questions including the North American Spine Society (NASS) patient satisfaction scale. For short-term and long-term effects, age difference was evaluated by the Mann-Whitney U test, and gender, duration of symptoms, level of DLSS, spondylolisthesis, and previous operations were evaluated by Fisher's exact test. Two hundred and sixteen patients (male: female = 75:141; mean age 69.2 years; range 48{proportional_to}91 years) were included in the study. Improvements (slightly improved, much improved, no pain) were seen in 185 patients (85.6%) after an initial caudal ESI and in 189 patients (87.5%) after a series of caudal ESIs. Half of the patients (89/179, 49.8%) replied positively to the NASS patient satisfaction scale (1 or 2). There were no significant outcome predictors for either the short-term or the long-term responses. Fluoroscopically guided caudal ESI was effective for the management of DLSS (especially central canal stenosis) with excellent short-term and good long-term results, without significant outcome predictors. (orig.)

  2. Long-term persistence with injectable therapy in relapsing-remitting multiple sclerosis: an 18-year observational cohort study.

    Directory of Open Access Journals (Sweden)

    Simon Zhornitsky

    Full Text Available Disease modifying therapies (DMTs reduce the frequency of relapses and accumulation of disability in multiple sclerosis (MS. Long-term persistence with treatment is important to optimize treatment benefit. This long-term, cohort study was conducted at the Calgary MS Clinic. All consenting adults with relapsing-remitting MS who started either glatiramer acetate (GA or interferon-β 1a/1b (IFN-β between January 1st, 1996 and July 1st, 2011 were included. Follow-up continued to February 1st, 2014. Time-to-discontinuation of the initial and subsequently-prescribed DMTs (switches was analysed using Kaplan-Meier survival analyses. Group differences were compared using log-rank tests and multivariable Cox regression models. Analysis included 1471 participants; 906 were initially prescribed GA and 565 were initially prescribed IFN-β. Follow-up information was available for 87%; 29 (2% were lost to follow-up and 160 (11% moved from Southern Alberta while still using DMT. Median time-to-discontinuation of all injectable DMTs was 11.1 years. Participants with greater disability at treatment initiation, those who started treatment before age 30, and those who started between 2006 and 2011 were more likely to discontinue use of all injectable DMTs. Median time-to-discontinuation of the initial DMT was 8.6 years. Those initially prescribed GA remained on treatment longer. Of 610 participants who discontinued injectable DMT, 331 (54% started an oral DMT, or a second-line DMT, or resumed injectable DMT after 90 days. Persistence with injectable DMTs was high in this long-term population-based study. Most participants who discontinued injectable DMT did not remain untreated. Further research is required to understand treatment outcomes and outcomes after stopping DMT.

  3. Experiment data report for Semiscale Mod-1 Test S-05-5 (alternate ECC injection test)

    International Nuclear Information System (INIS)

    Collins, B.L.; Patton, M.L. Jr.; Sackett, K.E.

    1977-04-01

    Recorded test data are presented for Test S-05-5 of the Semiscale Mod-1 alternate ECC injection test series. These tests are among several Semiscale Mod-1 experiments conducted to investigate the thermal and hydraulic phenomena accompanying a hypothesized loss-of-coolant accident in a pressurized water reactor (PWR) system. Test S-05-5 was conducted from initial conditions of 2263 psia and 537 0 F to investigate the response of the Semiscale Mod-1 system to a depressurization and reflood transient following a simulated double-ended offset shear of the cold leg broken loop piping. During the test, cooling water was injected into the cold leg of the intact and broken loops to simulate emergency core coolant injection in a PWR. The upper plenum was vented through a reflood bypass line interconnecting the hot and cold legs of the broken loop

  4. Riboflavin laurate nanosuspensions as an intramuscular injection for long-term riboflavin supplementation.

    Science.gov (United States)

    Du, Lina; Li, Guanglong; Jin, Yiguang; Wang, Lin; Xu, Qishou; Dong, Junxing

    2013-06-25

    The aim of this study was to prepare riboflavin laurate (RFL) nanosuspensions as an intramuscular injection for long-term riboflavin supplementation. Stable RFL nanosuspensions were obtained by injecting RFL/poloxamer solution in N,N-dimethyl formamide into a trehalose solution. Long soft nanostructures initially appeared and then tube-like rigid nanostructures were obtained after removal of solvents according to the transmission electron microscopic images. The nanosuspensions had narrow size distribution and the mean size was about 300 nm. Molecular self-assembly of RFL may drive the formation of nanostructures. RFL formed a monolayer at the air/water interface and poloxamer 188 could insert into the monolayer. The nanosuspensions were intramuscularly injected into rats to provide long-term riboflavin supplementation for more than 30 days in light of body weight, food intake, and urinary riboflavin. The nanosuspensions were also used to resist the riboflavin deficiency induced by methotrexate chemotherapy. RFL nanosuspensions are a promising nanomedicine for long-term riboflavin supplementation. Copyright © 2013 Elsevier B.V. All rights reserved.

  5. Diabetes Fear of Injecting and Self-Testing Questionnaire

    DEFF Research Database (Denmark)

    Mollema, E D; Snoek, Frank J; Pouwer, F

    2000-01-01

    OBJECTIVE: To study the psychometric properties of the Diabetes Fear of Injecting and Self-Testing Questionnaire (D-FISQ). RESEARCH DESIGN AND METHODS: Two groups of patients were studied. Sample A consisted of 252 insulin-treated diabetes patients. Sample B incorporated 24 insulin-treated patients......-injecting or self-testing had higher scores on FSI (P = 0.095) and FST (P = 0.01). EFA yielded 2 separate factors, FSI and FST. CONCLUSIONS: Results from this study support reliability and validity of the D-FISQ, a self-report instrument that can be used for both clinical and research purposes....

  6. Lightning Pin Injection Testing on MOSFETS

    Science.gov (United States)

    Ely, Jay J.; Nguyen, Truong X.; Szatkowski, George N.; Koppen, Sandra V.; Mielnik, John J.; Vaughan, Roger K.; Wysocki, Philip F.; Celaya, Jose R.; Saha, Sankalita

    2009-01-01

    Lightning transients were pin-injected into metal-oxide-semiconductor field-effect transistors (MOSFETs) to induce fault modes. This report documents the test process and results, and provides a basis for subsequent lightning tests. MOSFETs may be present in DC-DC power supplies and electromechanical actuator circuits that may be used on board aircraft. Results show that unprotected MOSFET Gates are susceptible to failure, even when installed in systems in well-shielded and partial-shielded locations. MOSFET Drains and Sources are significantly less susceptible. Device impedance decreased (current increased) after every failure. Such a failure mode may lead to cascading failures, as the damaged MOSFET may allow excessive current to flow through other circuitry. Preliminary assessments on a MOSFET subjected to 20-stroke pin-injection testing demonstrate that Breakdown Voltage, Leakage Current and Threshold Voltage characteristics show damage, while the device continues to meet manufacturer performance specifications. The purpose of this research is to develop validated tools, technologies, and techniques for automated detection, diagnosis and prognosis that enable mitigation of adverse events during flight, such as from lightning transients; and to understand the interplay between lightning-induced surges and aging (i.e. humidity, vibration thermal stress, etc.) on component degradation.

  7. Short-term outcome of fluoroscopic-guided steroid injection therapy of lumber facet cyst-induced radicular pain

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Mi Ri; Kwon, Jong Won; Lee, Jong Seo; Kim, Eu Sang [Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2015-04-15

    To determine the short-term effect of fluoroscopic-guided steroid injection therapy of lumbar facet cyst-induced radicular pain. Seventeen patients with radiculopathy due to lumbar synovial cysts, who were treated with fluoroscopically guided injection, were retrospectively evaluated. All plain radiographic images and MR images before the therapy were reviewed. Five patients underwent only the facet joint injection, whereas twelve patients underwent the facet joint injection with perineural injection therapy. The clinical course of pain was evaluated on the first follow-up after therapy. Effective pain relief was achieved in 11 (64.7%) of the 17 patients. Among 12 patients who underwent facet joint injection with perineural injection, 9 patients (75%) had an effective pain relief. Of 5 patients, 2 (40%) patients only took the facet joint injection and had an effective pain relief. Fluoroscopic-guided steroid injection therapy shows a good short-term effect in patients with symptomatic lumbar facet joint synovial cysts.

  8. Aboveground Injection Sytem Construction and Mecahnical Integrity Test Plan

    Energy Technology Data Exchange (ETDEWEB)

    Li, Jun [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-10-01

    An In-Situ Bioremediation (ISB) Pilot Test Treatability Study is planned at Sandia National Laboratories, New Mexico (SNL/NM) Technical Area-V (TA-V) Groundwater Area of Concern. The Treatability Study is designed to gravity inject an electron-donor substrate and bioaugmentation bacteria into groundwater using an injection well. The constituents of concern (COCs) are nitrate and trichloroethene (TCE). The Pilot Test Treatability Study will evaluate the effectiveness of bioremediation and COC treatment over a prescribed period of time. Results of the pilot test will provide data that will be used to evaluate the cost and effectiveness of a fullscale system.

  9. Data Acquisition for Low-Temperature Geothermal Well Tests and Long-Term Monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Lienau, P J

    1992-03-01

    Groundwater monitoring is an essential part of the development of a low-temperature geothermal field for production and injection wells. State water resource and environmental departments are requiring both geothermal well testing and long-term monitoring as a part of the permitting process for geothermal developments. This report covers water-level measurement methods, instruments used for well testing, geochemical sampling, examples of data acquisition and regulatory mandates on groundwater monitoring.

  10. Data acquisition for low-temperature geothermal well tests and long-term monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Lienau, P.J.

    1992-09-01

    Groundwater monitoring is an essential part of the development of a low-temperature geothermal field for production and injection wells. State water resource and environmental departments are requiring both geothermal well testing and long-term monitoring as a part of the permitting process for geothermal developments. This report covers water-level measurement methods, instruments used for well testing, geochemical sampling, examples of data acquisition and regulatory mandates on groundwater monitoring.

  11. Control, data acquisition and analysis for the JET neutral injection test bed

    International Nuclear Information System (INIS)

    Jones, T.T.C.; Brenan, P.R.; Rodgers, M.E.; Stork, D.; Young, I.D.

    1984-01-01

    The Neutral Injection Test-Bed (NITB) is a major experimental assembly in support of the Neutral Beam Heating Programme for JET. In addition to its prime function of testing the Neutral Injection hardware, the Test Bed serves as the prototype to test the computer control and data acquisition system, which is described. (author)

  12. Control, data acquisition and analysis for the JET neutral injection test bed

    International Nuclear Information System (INIS)

    Jones, T.T.C.; Brenan, P.R.; Rodgers, M.E.; Stork, D.; Young, I.D.

    1985-01-01

    The Neutral Injection Test-Bed (NITB) is a major experimental assembly in support of the Neutral Beam Heating Programme for JET. In addition to its prime function of testing the Neutral Injection hardware, the Test Bed serves as the prototype to test the computer control and data acquisition system, which is described in this paper. The software system has been written in a portable, data-driven manner with the aim to adapt it, with only minor modifications to the operation of the first. Neutral Injection Beamline on JET, which will involve operation both synchronous and asynchronous with that of the JET Tokamak

  13. Field Testing of Activated Carbon Injection Options for Mercury Control at TXU's Big Brown Station

    Energy Technology Data Exchange (ETDEWEB)

    John Pavlish; Jeffrey Thompson; Christopher Martin; Mark Musich; Lucinda Hamre

    2009-01-07

    The primary objective of the project was to evaluate the long-term feasibility of using activated carbon injection (ACI) options to effectively reduce mercury emissions from Texas electric generation plants in which a blend of lignite and subbituminous coal is fired. Field testing of ACI options was performed on one-quarter of Unit 2 at TXU's Big Brown Steam Electric Station. Unit 2 has a design output of 600 MW and burns a blend of 70% Texas Gulf Coast lignite and 30% subbituminous Powder River Basin coal. Big Brown employs a COHPAC configuration, i.e., high air-to-cloth baghouses following cold-side electrostatic precipitators (ESPs), for particulate control. When sorbent injection is added between the ESP and the baghouse, the combined technology is referred to as TOXECON{trademark} and is patented by the Electric Power Research Institute in the United States. Key benefits of the TOXECON configuration include better mass transfer characteristics of a fabric filter compared to an ESP for mercury capture and contamination of only a small percentage of the fly ash with AC. The field testing consisted of a baseline sampling period, a parametric screening of three sorbent injection options, and a month long test with a single mercury control technology. During the baseline sampling, native mercury removal was observed to be less than 10%. Parametric testing was conducted for three sorbent injection options: injection of standard AC alone; injection of an EERC sorbent enhancement additive, SEA4, with ACI; and injection of an EERC enhanced AC. Injection rates were determined for all of the options to achieve the minimum target of 55% mercury removal as well as for higher removals approaching 90%. Some of the higher injection rates were not sustainable because of increased differential pressure across the test baghouse module. After completion of the parametric testing, a month long test was conducted using the enhanced AC at a nominal rate of 1.5 lb/Macf. During

  14. THE STUDY OF GAS MIGRATION IN CRYSTALLINE ROCK USING INJECTION TESTS

    Directory of Open Access Journals (Sweden)

    Jiří Svoboda

    2012-07-01

    Full Text Available The study of gas migration in crystalline rock using injection tests is being carried out in the frame of the FORGE (Fate of Repository Gases project. The Czech Technical University in Prague (CTU, Centre of Experimental Geotechnics (CEG is participating in WP4 which is focused on disturbed host rock formations with respect to radioactive waste deep repositories. A series of in-situ tests is being conducted at the Josef Underground Laboratory. The aim of the testing is to simulate and study phenomena that might lead to gas-driven radionuclide transport in fractured crystalline rock. The in-situ tests combine migration and large-scale gas injection measurements; gas injection tests are being employed for the study of gas transport. For the purposes of comparison of the behaviour of the rock mass with regard to air and water a series of water pressure tests are also being carried out. The quality of the rock mass is assessed using rock mass classification systems.

  15. Ambiguity in measuring matrix diffusion with single-well injection/recovery tracer tests

    Science.gov (United States)

    Lessoff, S.C.; Konikow, Leonard F.

    1997-01-01

    Single-well injection/recovery tracer tests are considered for use in characterizing and quantifying matrix diffusion in dual-porosity aquifers. Numerical modeling indicates that neither regional drift in homogeneous aquifers, nor heterogeneity in aquifers having no regional drift, nor hydrodynamic dispersion significantly affects these tests. However, when drift is coupled simultaneously with heterogeneity, they can have significant confounding effects on tracer return. This synergistic effect of drift and heterogeneity may help explain irreversible flow and inconsistent results sometimes encountered in previous single-well injection/recovery tracer tests. Numerical results indicate that in a hypothetical single-well injection/recovery tracer test designed to demonstrate and measure dual-porosity characteristics in a fractured dolomite, the simultaneous effects of drift and heterogeneity sometimes yields responses similar to those anticipated in a homogeneous dual-porosity formation. In these cases, tracer recovery could provide a false indication of the occurrence of matrix diffusion. Shortening the shut-in period between injection and recovery periods may make the test less sensitive to drift. Using multiple tracers having different diffusion characteristics, multiple tests having different pumping schedules, and testing the formation at more than one location would decrease the ambiguity in the interpretation of test data.

  16. Fluoroscopically Guided Sacroiliac Joint Injections: Comparison of the Effects of Intraarticular and Periarticular Injections on Immediate and Short-Term Pain Relief.

    Science.gov (United States)

    Nacey, Nicholas C; Patrie, James T; Fox, Michael G

    2016-11-01

    The purpose of this study was to determine whether intraarticular sacroiliac joint injections provide greater immediate and short-term pain relief than periarticular sacroiliac joint injections do. The records of all fluoroscopically guided sacroiliac joint injections performed over a 4-year period were identified. Patients who received an injection of 0.5 mL of bupivacaine and 0.5 mL (20 mg) of triamcinolone and who had preinjection, immediate, and 1-week postinjection pain scores (0-10 numeric scale) were included. Images from the procedures were retrospectively reviewed by two musculoskeletal radiologists to determine intraarticular or periarticular administration of the injection with discrepancies resolved by consensus. One hundred thirteen injections in 99 patients (65 women, 34 men; mean age, 59.4 years) met the inclusion criteria. There were 55 intraarticular and 58 periarticular injections. The mean preinjection, immediate, and 1-week postinjection pain scores for the intraarticular injections were 6.0, 1.6, and 4.1 and for the periarticular injections were 6.1, 2.0, and 4.2. The mean immediate and 1-week postinjection pain reduction were statistically significant in both groups (p sacroiliac joint injections provide statistically significant immediate and 1-week postinjection pain relief, no significant difference in the degree of pain relief achieved with intraarticular and periarticular injections was noted.

  17. Results of zinc injection test for Hamaoka Unit-1

    International Nuclear Information System (INIS)

    Kani, K.; Masuda, H.; Hayashi, Y.; Sudo, S.; Yamazaki, K.

    1998-01-01

    A zinc injection test was preformed at Hamaoka Nuclear Power Station Unit-1 for suppressing radiation dose rate on primary coolant recirculation piping after the replacement of piping. Zinc ion was injected by using injection system where Depleted Zinc Oxide was dissolved in carbonated water. Controllability of the system was sufficient to maintain concentration of zinc in primary water. The concentration of zinc in the primary coolant was controlled from 1 ppb to 5 ppb gradually. The increasing trend of concentration of Co-60 in the coolant was suppressed at zinc concentration of 3 ppb. It is evaluated that the deposition coefficient of Co-60 onto the surface of primary coolant recirculation piping was suppressed to one-third of previous cycle in average, and one-fourth of that just before injection start at zinc concentration of 5 ppb. We concluded that zinc injection is effective for suppressing dose rate on the primary coolant piping and no adverse effect occurs by zinc injection up to 5 ppb in the primary coolant. (J.P.N.)

  18. Study on scan timing using a test injection method in head CTA

    International Nuclear Information System (INIS)

    Sekito, Yuichi; Sanada, Hidenori

    2005-01-01

    In head computed tomographic angiography (CTA), circulation from arterial phase to venous phase is more rapid than that in other regions. Therefore, it is necessary to determine correct scan timing to obtain ideal CTA images. A test injection method makes it possible to set correct scan timing from the time density curve (TDC) for each subject. The method, however, has a weak point that is a time lag in an arrival time at peak point of contrast medium on TDC between the test injection and the primary examination because of the difference in total volume of contrast medium used. The purpose of this study calculated the delay time on the TDC in both scans. We used the test injection method and the bolus tracking method in the primary examination. The average errors in start time (Δt1) and slope change time (Δt2) of the contrast medium on the TDC between test injection and primary examination were 0.15 sec and 3.05 sec, respectively. The results indicated that it was important to grasp the delay time in start time and peak arrival time of the contrast medium between test injection and primary examination to obtain ideal images in head CTA. (author)

  19. Short-term cessation of sex work and injection drug use: evidence from a recurrent event survival analysis.

    Science.gov (United States)

    Gaines, Tommi L; Urada, Lianne A; Martinez, Gustavo; Goldenberg, Shira M; Rangel, Gudelia; Reed, Elizabeth; Patterson, Thomas L; Strathdee, Steffanie A

    2015-06-01

    This study quantitatively examined the prevalence and correlates of short-term sex work cessation among female sex workers who inject drugs (FSW-IDUs) and determined whether injection drug use was independently associated with cessation. We used data from FSW-IDUs (n=467) enrolled into an intervention designed to increase condom use and decrease sharing of injection equipment but was not designed to promote sex work cessation. We applied a survival analysis that accounted for quit-re-entry patterns of sex work over 1-year stratified by city, Tijuana and Ciudad Juarez, Mexico. Overall, 55% of participants stopped sex work at least once during follow-up. Controlling for other characteristics and intervention assignment, injection drug use was inversely associated with short-term sex work cessation in both cities. In Ciudad Juarez, women receiving drug treatment during follow-up had a 2-fold increase in the hazard of stopping sex work. In both cities, income from sources other than sex work, police interactions and healthcare access were independently and significantly associated with shorter-term cessation. Short-term sex work cessation was significantly affected by injection drug use. Expanded drug treatment and counseling coupled with supportive services such as relapse prevention, job training, and provision of alternate employment opportunities may promote longer-term cessation among women motivated to leave the sex industry. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Anesthetic efficacy of a repeated intraosseous injection following a primary intraosseous injection.

    Science.gov (United States)

    Jensen, Joanne; Nusstein, John; Drum, Melissa; Reader, Al; Beck, Mike

    2008-02-01

    The purpose of this prospective, randomized, single-blinded study was to determine the anesthetic efficacy of a repeated intraosseous injection given 30 minutes after a primary intraosseous injection. Using a crossover design, 55 subjects randomly received a primary X-tip intraosseous injection (Dentsply Inc, York, PA) of 1.4 mL of 2% lidocaine with epinephrine (using the Wand; Milestone Scientific, Deerfield, IL) and a repeated intraosseous or mock injection at 30 minutes in two appointments. The first molar and adjacent teeth were pulp tested every 2 minutes for a total of 120 minutes. Success was defined as obtaining two consecutive 80 readings with the electric pulp tester. Success of the initial intraosseous injection was 100% for the first molar. The repeated intraosseous injection mimicked the initial intraosseous injection in terms of pulpal anesthesia and statistically provided another 15 minutes of pulpal anesthesia. In conclusion, using the methodology presented, repeating the intraosseous injection 30 minutes after an initial intraosseous injection will provide an additional 15 minutes of pulpal anesthesia.

  1. Controlled CO2 injection into a shallow aquifer and leakage detection monitoring practices at the K-COSEM site, Korea

    Science.gov (United States)

    Lee, S. S.; Joun, W.; Ju, Y. J.; Ha, S. W.; Jun, S. C.; Lee, K. K.

    2017-12-01

    Artificial carbon dioxide injection into a shallow aquifer system was performed with two injection types imitating short- and long-term CO2 leakage events into a shallow aquifer. One is pulse type leakage of CO2 (6 hours) under a natural hydraulic gradient (0.02) and the other is long-term continuous injection (30 days) under a forced hydraulic gradient (0.2). Injection and monitoring tests were performed at the K-COSEM site in Eumseong, Korea where a specially designed well field had been installed for artificial CO2 release tests. CO2-infused and tracer gases dissolved groundwater was injected through a well below groundwater table and monitoring were conducted in both saturated and unsaturated zones. Real-time monitoring data on CO2 concentration and hydrochemical parameters, and periodical measurements of several gas tracers (He, Ar, Kr, SF6) were obtained. The pulse type short-term injection test was carried out prior to the long-term injection test. Results of the short-term injection test, under natural hydraulic gradient, showed that CO2 plume migrated along the preferential pathway identified through hydraulic interference tests. On the other hand, results of the long-term injection test indicated the CO2 plume migration path was aligned to the forced hydraulic gradient. Compared to the short-term test, the long-term injection formed detectable CO2 concentration change in unsaturated wellbores. Recovery data of tracer gases made breakthrough curves compatible to numerical simulation results. The monitoring results indicated that detection of CO2 leakage into groundwater was more effectively performed by using a pumping and monitoring method in order to capture by-passing plume. With this concept, an effective real-time monitoring method was proposed. Acknowledgement: Financial support was provided by the "R&D Project on Environmental Management of Geologic CO2storage" from the KEITI (Project number : 2014001810003)

  2. Zinc injection during Hot Functional Test (HFT) in Tomari Unit 3

    International Nuclear Information System (INIS)

    Hayakawa, H.; Mino, Y.; Nakahama, S.; Aizawa, Y.; Nishimura, T.; Umehara, R.; Shimuz, Y.; Kogawa, N.; Ojima, Z.

    2010-01-01

    Zinc injection is performed to reduce radiation exposure around the world, and its effect is confirmed. In Japanese PWRs, the actual effect is also confirmed. Therefore, number of Japanese PWR plans, where zinc is injected, increase. We conclude that zinc injection from Hot Function Test (HFT), when RCS temperature and corrosion rate of material of primary components are increased firstly, is more effective for reducing radiation exposure, because oxide layer with zinc is more stable than with other metals such as cobalt and it is confirmed that zinc injection reduces corrosion amount of alloy 690TT in laboratory test. Therefore in Tomari Unit 3 (PWR, commercial operation from December 2009) of HOKKAIDO ELECTRIC POWER CO., INC, zinc injection was started from first Heat-up during trial operation. During HFT, zinc consumption coincides with assumed plan and Ni concentration is lower than in reference plant. Therefore we conclude that stable and fine oxide layer including zinc is formed. We hope that radiation exposure reduces because of these results. (We published at Asia Water Chemistry Symposium 2009 in NAGOYA.) Results of analysis of oxide layer on SG insert plate, removed after HFT, will be reported. Also Actual results of water chemistry and zinc injection after HFT will be reported. (author)

  3. Comparison of long-term voice outcomes after vocal fold augmentation using autologous fat injection by direct microlaryngoscopy versus office-based calcium hydroxylapatite injection.

    Science.gov (United States)

    Zeleník, Karol; Walderová, Radana; Kučová, Hana; Jančatová, Debora; Komínek, Pavel

    2017-08-01

    The objective is to compare the long-term voice outcomes of vocal fold augmentation (VFA) using autologous fat injection via direct microlaryngoscopy versus office-based calcium hydroxylapatite (CaHA) injection. Patients with glottal insufficiency and a gap no greater than 3 mm caused by unilateral vocal fold paralysis or vocal fold atrophy were prospectively recruited to the study from September 2012 to September 2015. From September 2012 to May 2014, VFA was only performed using autologous fat via direct microlaryngoscopy under general anesthesia (N = 14). From May 2014 to September 2015, VFA was performed as an office-based procedure using a transoral approach to inject CaHA (N = 17). Videolaryngostroboscopic evaluation, subjective satisfaction with voice, voice handicap index (VHI), and maximal phonation time (MPT) were analyzed pre-injection and 12 months after VFA. A total of 31 patients were analyzed. One year after VFA, 67.8% of the patients were satisfied with their voice, with no significant difference between groups (P = 0.247). The mean improvement in VHI in the autologous fat group was 31.6 ± 16.82 versus 35 ± 27.24 in the CaHA group (P = 0.664). MPT improvement was also similar in the two groups: 5.5 ± 2.52 for the autologous fat group versus 6.0 ± 3.98 for the CaHA group (P = 0.823). Both autologous fat injection via direct microlaryngoscopy and office-based CaHA injection have good long-term results. There were no differences in the treatment results of the two procedures 1 year after injection.

  4. Long-term CO2 injection and its impact on near-surface soil microbiology.

    Science.gov (United States)

    Gwosdz, Simone; West, Julia M; Jones, David; Rakoczy, Jana; Green, Kay; Barlow, Tom; Blöthe, Marco; Smith, Karon; Steven, Michael; Krüger, Martin

    2016-12-01

    Impacts of long-term CO 2 exposure on environmental processes and microbial populations of near-surface soils are poorly understood. This near-surface long-term CO 2 injection study demonstrated that soil microbiology and geochemistry is influenced more by seasonal parameters than elevated CO 2 Soil samples were taken during a 3-year field experiment including sampling campaigns before, during and after 24 months of continuous CO 2 injection. CO 2 concentrations within CO 2 -injected plots increased up to 23% during the injection period. No CO 2 impacts on geochemistry were detected over time. In addition, CO 2 -exposed samples did not show significant changes in microbial CO 2 and CH 4 turnover rates compared to reference samples. Likewise, no significant CO 2 -induced variations were detected for the abundance of Bacteria, Archaea (16S rDNA) and gene copy numbers of the mcrA gene, Crenarchaeota and amoA gene. The majority (75%-95%) of the bacterial sequences were assigned to five phyla: Firmicutes, Proteobacteria, Actinobacteria, Acidobacteria and Bacteroidetes The majority of the archaeal sequences (85%-100%) were assigned to the thaumarchaeotal cluster I.1b (soil group). Univariate and multivariate statistical as well as principal component analyses showed no significant CO 2 -induced variation. Instead, seasonal impacts especially temperature and precipitation were detected. © FEMS 2016. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  5. Short-term outcome after intravitreal ranibizumab injections for the treatment of retinopathy of prematurity.

    Science.gov (United States)

    Castellanos, María Ana Martínez; Schwartz, Shulamit; García-Aguirre, Gerardo; Quiroz-Mercado, Hugo

    2013-07-01

    To evaluate ocular outcome in premature infants treated with intravitreal ranibizumab injections for retinopathy of prematurity (ROP) over a period of 3 years. An interventional case series. Premature infants with high-risk prethreshold or threshold ROP with plus disease received an off label monotherapy with intravitreal injections of ranibizumab. The primary outcome was treatment success defined as regression of neovascularisation (NV) and absence of recurrence. The secondary outcomes were ocular and systemic adverse events and visual acuity. Six eyes were included in the study and treated with intravitreal injections of ranibizumab. All showed complete resolution of NV after a single injection. The anti-angiogenic intravitreal injections allowed for continued normal vessel growth into the peripheral retina, without any signs of disease recurrence or progression during the follow up period. No ocular or systemic adverse effects were observed. Three years of follow up in a small series suggest that intravitreal ranibizumab injections for ROP result in apparently preserved ocular outcome. Further large scale studies are needed to address the long-term safety and efficacy.

  6. Long-term continuous energy injection in the afterglow of GRB 060729

    International Nuclear Information System (INIS)

    Xu Ming; Huang Yongfeng; Lu Tan

    2009-01-01

    A long plateau phase and an amazing level of brightness have been observed in the X-ray afterglow of GRB 060729. This peculiar light curve is likely due to long-term energy injection in external shock. Here, we present a detailed numerical study of the energy injection process of magnetic dipole radiation from a strongly magnetized millisecond pulsar and model the multi-band afterglow observations. It is found that this model can successfully explain the long plateaus in the observed X-ray and optical afterglow light curves. The sharp break following the plateaus could be due to the rapid decline of the emission power of the central pulsar. At an even later time (∼ 5 x 10 6 s), an obvious jet break appears, which implies a relatively large half opening angle of θ ∼ 0.3 for the GRB ejecta. Due to the energy injection, the Lorentz factor of the outflow is still larger than two even at 10 7 s after the GRB trigger, making the X-ray afterglow of this burst detectable by Chandra even 642 d after the burst.

  7. Intrathecal injection of naked plasmid DNA provides long-term expression of secreted proteins.

    Science.gov (United States)

    Hughes, Travis S; Langer, Stephen J; Johnson, Kirk W; Chavez, Raymond A; Watkins, Linda R; Milligan, Erin D; Leinwand, Leslie A

    2009-01-01

    Therapeutic benefit has been reported to result from intrathecal (i.t.) injection of transgene vectors, including naked DNA. However, most studies using naked DNA have measured only the transgene expression of intracellular proteins. Here we demonstrate that i.t. injection of naked DNA can result in long-term expression of secreted proteins. Plasmids expressing either secreted alkaline phosphatase (SEAP) or human interleukin-10 (hIL-10) were injected into the i.t. space in rats, and transgene products were repeatedly measured in the cerebrospinal fluid (CSF). Both SEAP and hIL-10 were maximal at 1 and 2 days after the injection and still detectable at 4 months. The utilization of a plasmid having two features that are hypothesized to increase gene expression (matrix attachment regions (MARs) and lack of CpG dinucleotides) resulted in a significant increase in gene expression. Reinjection of SEAP or hIL-10 plasmids after 4 months significantly increased protein levels at 1 and 14 days after the reinjection. SEAP was uniformly distributed between the DNA delivery site (approximately vertebral level T13) and the lumbar puncture site (L5/L6 inter-vertebral space), was reduced at the cisterna magna, and was detectable, though at much lower levels, in serum. These data suggest that naked DNA has the potential to be used as a therapeutic tool for applications that require long-term release of transgenes into the CSF.

  8. Short-term muscle atrophy caused by botulinum toxin-A local injection impairs fracture healing in the rat femur.

    Science.gov (United States)

    Hao, Yongqiang; Ma, Yongcheng; Wang, Xuepeng; Jin, Fangchun; Ge, Shengfang

    2012-04-01

    Damaged bone is sensitive to mechanical stimulation throughout the remodeling phase of bone healing. Muscle damage and muscular atrophy associated with open fractures and subsequent fixation are not beneficial to maintaining optimum conditions for mechanical stability. The aim of this study was to investigate whether local muscle atrophy and dysfunction affect fracture healing in a rat femur fracture model. We combined the rat model of a short period atrophy of the quadriceps with femur fracture. Forty-four-month-old male Wistar rats were adopted for this study. Two units of botulinum toxin-A (BXTA) were administered locally into the right side of the quadriceps of each rat, while the same dose of saline was injected into the contralateral quadriceps. After BXTA had been fully absorbed by the quadriceps, osteotomy was performed in both femurs with intramedullary fixation. Gross observation and weighing of muscle tissue, X-ray analysis, callus histology, and bone biomechanical testing were performed at different time points up to 8 weeks post-surgery. Local injection of BXTA led to a significant decrease in the volume and weight of the quadriceps compared to the control side. At the eighth week, the left side femurs of the saline-injected quadriceps almost reached bony union, and fibrous calluses were completely calcified into woven bone. However, a gap was still visible in the BXTA-treated side on X-ray images. As showed by bone histology, there were no mature osseous calluses or woven bone on the BXTA-treated side, but a resorption pattern was evident. Biomechanical testing indicated that the femurs of the BXTA-treated side exhibited inferior mechanical properties compared with the control side. The inferior outcome following BXTA injection, compared with saline injection, in terms of callus resistance may be the consequence of unexpected load and mechanical unsteadiness caused by muscle atrophy and dysfunction. Copyright © 2011 Orthopaedic Research Society.

  9. Admissions of injection drug users to drug abuse treatment following HIV counseling and testing.

    Science.gov (United States)

    McCusker, J; Willis, G; McDonald, M; Lewis, B F; Sereti, S M; Feldman, Z T

    1994-01-01

    The outcomes of counseling and testing programs related to human immunodeficiency virus (HIV) infection and risk of infection among injection drug users (IDUs) are not well known or understood. A counseling and testing outcome of potential public health importance is attaining admission to drug abuse treatment by those IDUs who are either infected or who are at high risk of becoming infected. The authors investigated factors related to admission to drug abuse treatment among 519 IDUs who received HIV counseling and testing from September 1987 through December 1990 at a men's prison and at community-based testing sites in Worcester, MA. By June 1991, 123 of the 519 IDUs (24 percent) had been admitted to treatment. Variables associated with their admission included a long history of drug injection, frequent recent drug injection, cleaning injection equipment using bleach, prior drug treatment, and a positive HIV test result. Logistic regression analyses, controlling for effects of recruitment site, year, sex, and area of residence, generally confirmed the associations. IDUs in the study population who were HIV-infected sought treatment or were admitted to treatment more frequently than those who were not infected. The results indicate that access to drug abuse treatment should be facilitated for high-risk IDUs and for those who have begun to inject drugs recently.

  10. Polydimethylsiloxane Injection Laryngoplasty for Unilateral Vocal Fold Paralysis: Long-Term Results.

    Science.gov (United States)

    Mattioli, Francesco; Bettini, Margherita; Botti, Cecilia; Busi, Giulia; Tassi, Sauro; Malagoli, Andrea; Molteni, Gabriele; Trebbi, Marco; Luppi, Maria Pia; Bergamini, Giuseppe; Presutti, Livio

    2017-07-01

    To analyze the long-term objective, perceptive, and subjective outcomes after endoscopic polydimethylsiloxane (PDMS) injection laryngoplasty in unilateral vocal fold paralysis. A retrospective study carried out between January 2008 and January 2012. Head and Neck Department, University Hospital of Modena, Modena, Italy. This was a retrospective analysis of 26 patients with unilateral vocal fold paralysis who underwent endoscopic injection of PDMS under general anesthesia. A voice evaluation protocol was performed for all patients, which included videolaryngostroboscopy, maximum phonation time, fundamental frequency, analysis of the harmonic structure of the vowel /a/ and the word /aiuole/, Grade of Dysphonia, Instability, Roughness, Breathiness, Asthenia, and Strain scale, and Voice Handicap Index. The protocol was performed before surgery, in the immediate postoperative period, and at least 3 years after surgery. The mean follow-up period was 73 months (range 39-119 months). The statistical analysis showed a significant improvement (P injection laryngoplasty with PDMS guarantees long-lasting effects over time. No complications were reported in our series. Injection laryngoplasty with PDMS can be considered to be a minimally invasive and safe technique for the treatment of unilateral vocal fold paralysis. Moreover, it allows very good and stable results to be obtained over time, avoiding repeated treatments and improving the quality of life of the patients. Copyright © 2017 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  11. Air-injection testing in vertical boreholes in welded and nonwelded Tuff, Yucca Mountain, Nevada

    Energy Technology Data Exchange (ETDEWEB)

    LeCain, G.D.

    1997-12-31

    Air-injection tests, by use of straddle packers, were done in four vertical boreholes (UE-25 UZ-No.16, USW SD-12, USW NRG-6, and USW NRG-7a) at Yucca Mountain, Nevada. The geologic units tested were the Tiva Canyon Tuff, nonwelded tuffs of the Paintbrush Group, Topopah Spring Tuff, and Calico Hills Formation. Air-injection permeability values of the Tiva Canyon Tuff ranged from 0.3 x 10{sup -12} to 54.0 x 10{sup -12} m{sup 2}(square meter). Air-injection permeability values of the Paintbrush nonwelded tuff ranged from 0.12 x 10{sup -12} to 3.0 x 10{sup -12} m{sup 2}. Air-injection permeability values of the Topopah Spring Tuff ranged from 0.02 x 10{sup -12} to 33.0 x 10{sup -12} m{sup 2}. The air-injection permeability value of the only Calico Hills Formation interval tested was 0.025 x 10{sup -12} m{sup 2}. The shallow test intervals of the Tiva Canyon Tuff had the highest air-injection permeability values. Variograms of the air-injection permeability values of the Topopah Spring Tuff show a hole effect; an initial increase in the variogram values is followed by a decrease. The hole effect is due to the decrease in permeability with depth identified in several geologic zones. The hole effect indicates some structural control of the permeability distribution, possibly associated with the deposition and cooling of the tuff. Analysis of variance indicates that the air-injection permeability values of borehole NRG-7a of the Topopah Spring Tuff are different from the other boreholes; this indicates areal variation in permeability.

  12. Short-term intraocular pressure changes after intravitreal injection of bevacizumab in diabetic retinopathy patients

    Directory of Open Access Journals (Sweden)

    Farhood QK

    2014-03-01

    Full Text Available Qasim Kadhim Farhood,1 Sinan Mohammad Twfeeq21College of Medicine, Babylon University, Babylon; 2Al-Jumhori teaching hospital, Mosul, IraqBackground: This study examined the changes in short-term intraocular pressure (IOP in a prospective series of patients undergoing intravitreal bevacizumab injection. The aim was to evaluate the frequency and predictive factors related to intraocular pressure (IOP elevation in patients receiving intravitreal bevacizumab.Patients and methods: This study included 52 patients with diabetic retinopathy between 28 to 75 years of age with a mean age of 51 years; 30 (58% were females, and 22 (42% were males. All patients received bevacizumab (1.25 mg/0.05 mL injected intravitreally in a standard fashion between May 2012 to February 2013 in the AL-Jumhoury teaching hospital. IOP was measured at baseline, 5, 10, and 30 minutes after injection using Goldman applanation tonometry.Statistics: Data were analyzed using the SPSS v.12.0 for windows. Basic, demographic, and clinical data were analyzed using means, proportions, and appropriate 95% confidence intervals (CIs.Results: Most patients (85% were diagnosed with proliferative diabetic retinopathy, while 15% presented with diabetic macular edema. The mean IOP values at baseline, 5, 10, and 30 minutes after injection were 14.0 mmHg (95% CI 13.4–14.7, 36.1 mmHg (95% CI 33.5–38.6, 25.7 mmHg (95% CI 23.8–27.5, and 15.5 mmHg (95% CI 12.4–16.51, respectively. Regression analysis showed a trend toward phakic patients having higher IOP at 30 minutes.Conclusion: Intravitreal injection of bevacizumab is safe with respect to short-term IOP changes, as almost all IOP returned to a safe range (<25 mmHg within 30 minutes. Elevated IOP 30 minutes after injection only occurs rarely, so routine prophylactic use of anti-glaucoma medication is not indicated.Keywords: intravitreal injection, bevacizumab, intraocular pressure, Goldmann applanation tonometry

  13. Jet flow analysis of liquid poison injection in a CANDU reactor using source term

    International Nuclear Information System (INIS)

    Chae, Kyung Myung; Choi, Hang Bok; Rhee, Bo Wook

    2001-01-01

    For the performance analysis of Canadian deuterium uranium (CANDU) reactor shutdown system number 2 (SDS2), a computational fluid dynamics model of poison jet flow has been developed to estimate the flow field and poison concentration formed inside the CANDU reactor calandria. As the ratio of calandria shell radius over injection nozzle hole diameter is so large (1055), it is impractical to develop a full-size model encompassing the whole calandria shell. In order to reduce the model to a manageable size, a quarter of one-pitch length segment of the shell was modeled using symmetric nature of the jet; and the injected jet was treated as a source term to avoid the modeling difficulty caused by the big difference of the hole sizes. For the analysis of an actual CANDU-6 SDS2 poison injection, the grid structure was determined based on the results of two-dimensional real- and source-jet simulations. The maximum injection velocity of the liquid poison is 27.8 m/s and the mass fraction of the poison is 8000 ppm (mg/kg). The simulation results have shown well-established jet flow field. In general, the jet develops narrowly at first but stretches rapidly. Then, the flow recirculates a little in r-x plane, while it recirculates largely in r-θ plane. As the time goes on, the adjacent jets contact each other and form a wavy front such that the whole jet develops in a plate form. his study has shown that the source term model can be effectively used for the analysis of the poison injection and the simulation result of the CANDU reactor is consistent with the model currently being used for the safety analysis. In the future, it is strongly recommended to analyze the transient (from helium tank to injection nozzle hole) of the poison injection by applying Bernoulli equation with real boundary conditions

  14. Quick Look Report of the SMART ECC injection performance test I3

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Seok; Ko, Yong Ju; Cho, Young Il; Kim, Jeong Tak; Choi, Nam Hyun; Park, Choon Kyong; Kwon, Tae Soon; Lee, Sung Jae [KAERI, Daejeon (Korea, Republic of)

    2010-12-15

    The objective of this report is to describe test results of the Test I3 simulating the 2 inch SBLOCA of the SMART using the SWAT test facility. The Test I3 was performed to produce experimental data for the validation of the TASS/SMR-S thermal hydraulic analysis code, and to investigate the related thermal hydraulic phenomena in the down-comer region during the 2 inch SBLOCA of the safety inject line. The particular phenomena for the observation are ECC bypass and multi-dimensional flow characteristics to verify the effectiveness and performance of the safety injection system. In this report, the corresponding steady state test conditions, including initial and boundary conditions along with major measuring parameters, and related experimental results were described

  15. CT-guided cervical nerve root injections: comparing the immediate post-injection anesthetic-related effects of the transforaminal injection with a new indirect technique

    International Nuclear Information System (INIS)

    Sutter, Reto; Pfirrmann, Christian W.A.; Peterson, Cynthia K.; Zanetti, Marco; Hodler, Juerg

    2011-01-01

    To describe an ''indirect'' cervical nerve root injection technique with a dorsal approach that should carry less inherent risk than the ''direct'' cervical transforaminal injection approach, and to compare the immediate post-injection results of the two procedures. The indirect and direct cervical nerve root injection procedures are described in detail. Fifty-three consecutive patients receiving the indirect nerve root injections during 2009-2010 were age- and gender-matched to 53 patients who underwent direct transforaminal nerve root injections performed in 2006. Pain level data were collected immediately before and 20-30 min after each procedure. The percentages of pain change in the two groups were compared using the unpaired Student's t test. Fifty-two men (mean age 49) and 54 women (mean age 55) were included. The mean percentage of pain reduction for patients receiving indirect nerve root injections was 38.4% and for those undergoing the direct nerve root injections approach it was 43.2%. This was not significantly different (P = 0.455). No immediate or late adverse effects were reported after either injection procedure. The indirect cervical nerve root injection procedure is a potentially safer alternative to direct cervical transforaminal nerve root injections. The short-term pain reduction is similar using the two injection methods. (orig.)

  16. Simulation of the LHC injection kicker impedance test bench

    CERN Document Server

    Tsutsui, H

    2003-01-01

    The coupling impedance measurements of the LHC injection kicker test bench are simulated by HFSS code. The simulation gives qualitatively good agreement with the measurement. In order to damp the resonances, some ferrite rings are tested in the simulation. Longitudinal resonances are damped by a ferrite ring of large tan$\\delta_{\\mu}$. The effect of the ferrite ring is small for damping the transverse impedance resonance around 30 MHz.

  17. Evaluation of the long-term efficacy of CT-guided epidural steroid injection for the treatment of sciatica

    International Nuclear Information System (INIS)

    Tong Guohai; Wang Wei; Chen Wei; Chen Kemin

    2005-01-01

    Objective: To evaluate the long-term efficacy of CT-guided epidural steroid injection for the treatment of sciatica. Methods: CT-guided epidural steroid injection was performed in 180 patients with sciatica from May 1998 to March 2004, and all patients had failure to previous conservative treatment. Visual analogue scale was used to evaluate the pain of the patient before and after the treatment. Results: Follow-up was taken for 112 cases during 1-6 years after the treatment, 89 patients (79.5%) had successful long-term outcome and 80 patients (71.4%) were satisfied. Conclusions: CT-guided epidural steroid injection can reduce low back pain and radical pain. It should be preferentially considered as the first choice when conservative treatments are failed. (authors)

  18. Stability study of methotrexate in 0.9% sodium chloride injection and 5% dextrose injection with limit tests for impurities

    DEFF Research Database (Denmark)

    Nissen, Klaus; Bogedal Jorgensen, Lene; Lindegaard Berg, Dorthe

    2017-01-01

    Purpose. Results of an evaluation of the stability of methotrexate in 0.9% sodium chloride injection and 5% dextrose injection are presented. Methods. Methotrexate concentrated solution (100 mg/mL) was diluted to nominal concentrations of 0.2 and 20 mg/mL in infusion bags containing 0.9% sodium...... chloride injection or 5% dextrose injection. The filled bags were stored for 28 days at 25 °C and 60% relative humidity and protected from light. Samples were withdrawn for analysis on the day of preparation and after 3, 7, 14, 21, and 28 days. The test program included visual inspections, measurements...... in amounts of known and unknown degradation products were detected. In 5% dextrose injection, methotrexate at the higher concentration was stable for 28 days, with minor formation of degradation products; in the 0.2-mg/mL solution, however, methotrexate was stable for only 3 days. At later time points...

  19. Two injection digital block versus single subcutaneous palmar injection block for finger lacerations.

    Science.gov (United States)

    Okur, O M; Şener, A; Kavakli, H Ş; Çelik, G K; Doğan, N Ö; Içme, F; Günaydin, G P

    2017-12-01

    We aimed to compare two digital nerve block techniques in patients due to traumatic digital lacerations. This was a randomized-controlled study designed prospectively in the emergency department of a university-based training and research hospital. Randomization was achieved by sealed envelopes. Half of the patients were randomised to traditional (two-injection) digital nerve block technique while single-injection digital nerve block technique was applied to the other half. Score of pain due to anesthetic infiltration and suturing, onset time of total anesthesia, need for an additional rescue injection were the parameters evaluated with both groups. Epinephrin added lidocaine hydrochloride preparation was used for the anesthetic application. Visual analog scale was used for the evaluation of pain scores. Outcomes were compared by using Mann-Whitney U test and Student t-test. Fifty emergency department patients ≥18 years requiring digital nerve block were enrolled in the study. Mean age of the patients was 33 (min-max: 19-86) and 39 (78 %) were male. No statistically significant difference was found between the two groups in terms of our main parameters; anesthesia pain score, suturing pain score, onset time of total anesthesia and rescue injection need. Single injection volar digital nerve block technique is a suitable alternative for digital anesthesias in emergency departments.

  20. Injection-induced gluteus muscle contractures: diagnosis with the "reverse Ober test" and surgical management.

    Science.gov (United States)

    Scully, William F; White, Klane K; Song, Kit M; Mosca, Vincent S

    2015-03-01

    Adoption rates are increasing in the United States and other developed countries. A large proportion of adopted children have been found to have unsuspected medical diagnoses, including orthopedic problems. One condition, termed injection-induced gluteus maximus contracture, has been previously described in several case series and can be difficult to diagnose if unfamiliar with this condition. By reviewing the etiology and pathoanatomy of this problem, as well as the typical examination findings, including the near-pathognomonic-positive "reverse Ober test," treating providers will be better prepared to recognize and properly treat this condition. This is a retrospective review of 4 patients treated at our institution for injection-induced gluteus maximus contracture. Patient history, physical examination findings, and treatment outcomes were recorded. All had undergone surgical treatment through a longitudinal incision along the posterior margin of the iliotibial band, with division of thickened, contracted gluteus tissue down to the ischial tuberosity. All 4 of the patients were adopted from orphanages in developing countries. Chief complaints of the patients varied, but physical examination findings were very consistent. Three of the 4 patients had undergone rotational osteotomies for presumed femoral retroversion before their diagnosis and treatment for injection-induced gluteus maximus contracture. All patients had concave, atrophic buttock contours and numerous punctate buttock scars. All walked with an out-toed gait and had marked apparent femoral retroversion. Each patient was found to have full hip adduction when the hip was extended but a hip abduction contracture when the hip was flexed. This finding of increasing abduction as an extended/adducted hip is flexed to 90 degrees is described as a positive "reverse Ober test." After surgical treatment, all hips could adduct to neutral from full extension to full flexion. Although common in some countries

  1. Injection molded nanofluidic chips: Fabrication method and functional tests using single-molecule DNA experiments

    DEFF Research Database (Denmark)

    Utko, Pawel; Persson, Karl Fredrik; Kristensen, Anders

    2011-01-01

    We demonstrate that fabrication of nanofluidic systems can be greatly simplified by injection molding of polymers. We functionally test our devices by single-molecule DNA experiments in nanochannels.......We demonstrate that fabrication of nanofluidic systems can be greatly simplified by injection molding of polymers. We functionally test our devices by single-molecule DNA experiments in nanochannels....

  2. Long-term Dose Stability of OnabotulinumtoxinA Injection for Adductor Spasmodic Dysphonia: A 19-Year Single Institution Experience

    Directory of Open Access Journals (Sweden)

    Paul Paddle

    2017-11-01

    Full Text Available ObjectivesAdductor spasmodic dysphonia (AdSD is a focal dystonia predominantly involving the laryngeal adductor muscles. AdSD is reported to be a largely non-progressive neurological disorder, though fluctuations in symptom severity do occur. Repeated laryngeal onabotulinumtoxinA (BTX-A injections are the primary management for AdSD. A number of studies have demonstrated long-term dose stability as evidence of this long-term disease stability.MethodsA retrospective review was performed on all patients undergoing BTX-A injections for AdSD from April 1994 to September 2013 by a single laryngologist at a tertiary referral laryngology center. Patient demographics, injection doses, use of diazepam and/or lidocaine, and self-reported vocal function were recorded. Multiple linear regression analyses were performed.Results83 patients underwent a total of 1,168 injections over 19 years. The mean starting dose was 2.35 MU (0.79 SD. The mean long-term dose was 2.36 MU (0.79 SD. After adjusting for confounders, the change in the relative dose of BTX-A, with every year elapsed since initial dose was 0.13% (95% confidence interval −0.31 to 0.57%, p = 0.568.ConclusionBTX-A dose is stable over time in our large cohort of patients treated with bilateral thyroarytenoid injections for AdSD.

  3. Experiment data report for Semiscale Mod-1 Test S-05-2 (alternate ECC injection test)

    International Nuclear Information System (INIS)

    Feldman, E.M.; Collins, B.L.; Sackett, K.E.

    1977-02-01

    Recorded test data are presented for Test S-05-2 of the Semiscale Mod-1 alternate emergency core coolant (ECC) injection test series. This test is one of several Semiscale Mod-1 experiments conducted to investigate the thermal and hydraulic phenomena accompanying a hypothesized loss-of-coolant accident in a pressurized water reactor (PWR) system. Test S-05-2 was conducted from an initial cold leg fluid temperature of 545 0 F and an initial pressure of 2263 psia. A simulated double-ended offset shear cold leg break was used to investigate core and system response to a depressurization and reflood transient with ECC injection at the intact loop pump suction and broken loop cold leg. A reduced lower plenum volume was used for this test to more accurately represent the lower plenum of a PWR, based on system volume scaling. System flow was set to achieve a core fluid temperature differential of 65 0 F at a core power level of 1.44 MW. The flow resistance of the intact loop was based on core area scaling. An electrically heated core with a slightly peaked radial power profile was used in the pressure vessel to simulate the predicted surface heat flux of nuclear fuel rods during a loss-of-coolant accident

  4. Treatment of achalasia: the short-term response to botulinum toxin injection seems to be independent of any kind of pretreatment

    Directory of Open Access Journals (Sweden)

    Meining A

    2002-08-01

    Full Text Available Abstract Background It has been suggested that intrasphincteric injection of botulinum toxin (BTX may represent an alternative therapy to balloon dilatation in achalasia. The aim of the present study was to test the effectiveness of botulinum toxin injections in achalasia patients, as assessed using lower oesophageal sphincter pressure (LOSP and symptom scores, and to compare the response in patients with different types of pretreatment (no previous treatment, balloon dilatation, myotomy, BTX injection. Methods Forty patients who presented with symptomatic achalasia were treated with BTX injection (48 injections in 40 patients. Some of the patients had received prior treatment (seven with myotomy, seven with dilatation and eight with BTX. The symptoms were assessed using a global symptom score (0–10, which was evaluated before treatment, 1 week afterwards, and 1 month afterwards. Manometry was also carried out before and after treatment. Three different selections of patients were studied: all patients; untreated patients; and patients with prior BTX, dilatation, or myotomy. Results After BTX injection, there was a significant reduction in LOSP (before, 38.2 ± 11.3 mmHg; 1 week after, 20.5 ± 6.9 mmHg; 1 month after, 17.8 ± 6.8 mmHg; P Conclusions BTX injection offers an alternative treatment for achalasia which is safe and can be performed in an outpatient setting. The initial response to BTX, in terms of symptom scores and LOSP, appears to be independent of any prior treatment. A number of patients do not adequately respond to balloon dilatation or myotomy, which are the first-line treatment modalities in achalasia patients. BTX injection can be performed in these patients, and symptomatic benefit can be expected in the same percentages as with BTX injection in untreated patients.

  5. Air injection test on a Kaplan turbine: prototype - model comparison

    Science.gov (United States)

    Angulo, M.; Rivetti, A.; Díaz, L.; Liscia, S.

    2016-11-01

    Air injection is a very well-known resource to reduce pressure pulsation magnitude in turbines, especially on Francis type. In the case of large Kaplan designs, even when not so usual, it could be a solution to mitigate vibrations arising when tip vortex cavitation phenomenon becomes erosive and induces structural vibrations. In order to study this alternative, aeration tests were performed on a Kaplan turbine at model and prototype scales. The research was focused on efficiency of different air flow rates injected in reducing vibrations, especially at the draft tube and the discharge ring and also in the efficiency drop magnitude. It was found that results on both scales presents the same trend in particular for vibration levels at the discharge ring. The efficiency drop was overestimated on model tests while on prototype were less than 0.2 % for all power output. On prototype, air has a beneficial effect in reducing pressure fluctuations up to 0.2 ‰ of air flow rate. On model high speed image computing helped to quantify the volume of tip vortex cavitation that is strongly correlated with the vibration level. The hydrophone measurements did not capture the cavitation intensity when air is injected, however on prototype, it was detected by a sonometer installed at the draft tube access gallery.

  6. Client satisfaction among participants in a randomized trial comparing oral methadone and injectable diacetylmorphine for long-term opioid-dependency

    Directory of Open Access Journals (Sweden)

    Brissette Suzanne

    2011-07-01

    Full Text Available Abstract Background Substitution with opioid-agonists (e.g., methadone has shown to be an effective treatment for chronic long-term opioid dependency. Patient satisfaction with treatment has been associated with improved addiction treatment outcomes. However, there is a paucity of studies evaluating patients' satisfaction with Opioid Substitution Treatment (OST. In the present study, participants' satisfaction with OST was evaluated at 3 and 12 months. We sought to test the relationship between satisfaction and patients' characteristics, the treatment modality received and treatment outcomes. Methods Data from a randomized controlled trial, the North American Opiate Medication Initiative (NAOMI, conducted in Vancouver and Montreal (Canada between 2005-2008, was analyzed. The NAOMI study compared the effectiveness of oral methadone vs. injectable diacetylmorphine over 12 months. A small sub-group of patients received injectable hydromorphone on a double blind basis with diacetylmorphine. The Client Satisfaction Questionnaire (CSQ-8 was used to measure satisfaction with treatment. CSQ-8 scores, as well as retention and response to treatment, did not differ between those receiving hydromorphone and diacetylmorphine at 3 or 12 months assessments; therefore, these two groups were analyzed together as the 'injectable' treatment group. Results A total of 232 (92% and 237 (94% participants completed the CSQ-8 at 3 and 12 months, respectively. Participants in both groups were highly satisfied with treatment. Independent of treatment group, participants satisfied with treatment at 3 months were more likely to be retained at 12 months. Multivariate analysis indicated that satisfaction was greater among those randomized to the injection group after controlling for treatment effectiveness. Participants who were retained, responded to treatment, and had fewer psychological symptoms were more satisfied with treatment. Finally, open-ended comments were made by

  7. TRACKING TESTS FOR THE SNS FAST INJECTION BUMP POWER SUPPLY

    International Nuclear Information System (INIS)

    ENG, W.; CUTLER, R.; DEWAN, S.

    2004-01-01

    The tracking requirement of the SNS Fast Injection Bump power supplies is described. In addition to the usual tracking between the load current and the input reference of a power supply, these power supplies must also track between pairs of units under slightly different loads. This paper describes the use of a current-null test to measure tracking performances. For the actual tests, a single dummy magnet load was used to measure the tracking between the first two production units at the manufacturer's facility. Using the Yokogawa WE7000 waveform. PC-based measurement instrument, input and output waveforms are digitized and stored in data files. A program written for this application is then used to extract data from these files to construct, analyze the waveforms and characterize the power supply performance. Results of the measurements of two SNS Fast Injection Bump power supplies will be presented in this paper

  8. Long-term follow-up after urethral injection with polyacrylamide hydrogel for female stress incontinence

    DEFF Research Database (Denmark)

    Mouritsen, Lone; Lose, Gunnar; Møller-Bek, Karl

    2014-01-01

    Urethral injection therapy for treatment of stress urinary incontinence has been in use for years, but only a few long-term follow-up studies have been published. Twenty-five women, injected with polyacrylamide hydrogel 8 years earlier, were invited for follow-up. Twenty-four could be contacted; 15...... had had no further treatment, seven had been re-operated with placement of mid-urethral slings, and two had been re-injected with polyacrylamide hydrogel. Eleven women attended for objective examination; all non-attenders were interviewed by telephone. Subjectively, in 44% the stress incontinence...... was cured or much improved, with a positive outcome according to the King's Health Questionnaire. Objectively, all patients had visible polyacrylamide hydrogel deposits on vaginal ultrasonography. No local adverse reactions were seen in the vaginal mucosa. The results of a later mid-urethral sling were...

  9. Injection Laryngoplasty Materials

    OpenAIRE

    Haldun Oðuz

    2013-01-01

    Injection laryngoplasty is one of the treatment options for voice problems. In the recent years, more safe and more biocompatible injection materials are available on the market. Long and short term injection materials are discussed in this review.

  10. Proportion of long-term injection drug users as an indicator to characterize the state and prognosis of HIV-epidemic within a certain territory

    Directory of Open Access Journals (Sweden)

    Andreeva, Tatiana

    2012-07-01

    Full Text Available BACKGROUND: Epidemics of drug use and thus the spread of HIV have different duration in different regions, and, therefore, the prognosis of these epidemics may differ. We aimed to assess indicators measuring the peculiarities of injection drug use epidemics by region, informative for prevention activities among vulnerable to HIV groups. METHODS: Data from cross-sectional survey of 4026 injection drug users (IDUs conducted in 2007 in Ukraine were analyzed. The outcome measure was a binary variable depicting whether a respondent injects drugs for 20 years and over. Binary Logistic Regression in SPSS software was used to test associations with socio-demographic characteristics. RESULTS: More respondents from Odessa, Mykolayiv, Dnipropetrovsk, Cherkassy, Poltava, and Crimea regions inject over 20 years. Older respondents were more likely to belong to the group of long-term users. Men were more likely to inject over 20 years than women. Those respondents who were married, but did not live with their spouse or other sexual partner were more likely to inject longer than 20 years compared to those single or in a stable marriage. Those respondents who use opiates or combine them with stimulants were more likely to inject over 20 years and those who use only stimulants were more likely to inject less than 20 years. CONCLUSION: Injection drug use in Ukraine started earlier among men, on certain territories and was associated with opiate use. Percentage of IDUs who inject for more than 20 years was found to be a good indicator to distinguish territories with long-lasting epidemics.

  11. Irreversible muscle damage in bodybuilding due to long-term intramuscular oil injection.

    Science.gov (United States)

    Banke, I J; Prodinger, P M; Waldt, S; Weirich, G; Holzapfel, B M; Gradinger, R; Rechl, H

    2012-10-01

    Intramuscular oil injections generating slowly degrading oil-based depots represent a controversial subject in bodybuilding and fitness. However they seem to be commonly reported in a large number of non-medical reports, movies and application protocols for 'site-injections'. Surprisingly the impact of long-term (ab)use on the musculature as well as potential side-effects compromising health and sports ability are lacking in the medical literature. We present the case of a 40 year old male semi-professional bodybuilder with systemic infection and painful reddened swellings of the right upper arm forcing him to discontinue weightlifting. Over the last 8 years he daily self-injected sterilized sesame seed oil at numerous intramuscular locations for the purpose of massive muscle building. Whole body MRI showed more than 100 intramuscular rather than subcutaneous oil cysts and loss of normal muscle anatomy. 2-step septic surgery of the right upper arm revealed pus-filled cystic scar tissue with the near-complete absence of normal muscle. MRI 1 year later revealed the absence of relevant muscle regeneration. Persistent pain and inability to perform normal weight training were evident for at least 3 years post-surgery. This alarming finding indicating irreversible muscle mutilation may hopefully discourage people interested in bodybuilding and fitness from oil-injections. The impact of such chronic tissue stress on other diseases like malignancy remains to be determined. © Georg Thieme Verlag KG Stuttgart · New York.

  12. EXPERIMENTAL TARGET INJECTION AND TRACKING SYSTEM CONSTRUCTION AND SINGLE SHOT TESTING

    International Nuclear Information System (INIS)

    PETZOLDT, R.W.; ALEXANDER, N.B.; DRAKE, T.J.; GOODIN, D.T; JONESTRACK, K; VERMILLION, B.A

    2003-01-01

    Targets must be injected into an IFE power plant at a rate of approximately 5 to 10 Hz. Targets must be tracked very accurately to allow driver beams to be aligned with defined points on the targets with accuracy ± 150 (micro)m for indirect drive and ± 20 (micro)m for direct drive. An experimental target injection and tracking system has been constructed at General Atomics. The injector system will be used as a tool for testing the survivability of various target designs and provide feedback to the target designers. Helium gas propels the targets down an 8 m gun barrel up to 400 m/s. Direct-drive targets are protected in the barrel by sabots that are spring loaded to separate into two halves after acceleration. A sabot deflector directs the sabot halves away from the target injection path. Targets will be optically tracked with laser beams and line-scan cameras. Target position and arrival time will be predicted in real time based on early target position measurements. The system installation will be described. System testing to overcome excessive projectile wear and debris in the gun barrel is presented

  13. Safety of radiofrequency treatment over human skin previously injected with medium-term injectable soft-tissue augmentation materials: a controlled pilot trial.

    Science.gov (United States)

    Alam, Murad; Levy, Ross; Pajvani, Urvi; Pavjani, Urvi; Ramierez, James A; Guitart, Joan; Veen, Heather; Gladstone, Hayes B

    2006-03-01

    Several soft-tissue augmentation materials are now available for reduction of nasolabial fold creases and perioral rhytides. Nasolabial folds and perioral rhytides can also be improved by skin tightening delivered by non-ablative radiofrequency (RF) treatment. The purpose of this study was to assess the safety of RF treatment over skin areas recently injected with medium-term injectable soft-tissue augmentation materials. Five subjects were assigned to the experimental arm (augmentation materials plus RF) and one to the control arm (augmentation materials alone). Each subject received injections of 0.3 mL of hyaluronic acid derivative (Restylane) and calcium hydroxylapatite (Radiesse) 3 cm apart on the upper inner arm. Two weeks later, two non-overlapping passes of RF (Thermage ThermaCool TC) were delivered at 63.5 setting with medium-fast 1.5 cm2 tip over injected sites in all of the experimental subjects. Punch skin biopsies were obtained 3 days later from each of the two injection sites on each subject. Light microscopy and digital photomicrographs obtained at low, medium, and high power showed no difference between filler materials in experimental and control subjects. In both cases filler was evident at the deep dermal-subcutaneous junction. Nodule formation, foreign body extravasation, or hemorrhage/clot was not observed grossly or histologically. Subjects and physicians did not report any difference in signs and symptoms between the experimental and control arms. Slightly increased transitory pain was noted when RF was delivered over filler versus over normal skin. Applying RF treatment over the same area 2 weeks after deep dermal injection with hyaluronic acid derivatives or calcium hydroxylapatite does not appear to cause gross morphological changes in the filler material or surrounding skin. Further studies with different parameters are necessary to confirm these findings. 2006 Wiley-Liss, Inc.

  14. Sample and injection manifolds used to in-place test of nuclear air-cleaning system

    International Nuclear Information System (INIS)

    Qiu Dangui; Li Xinzhi; Hou Jianrong; Qiao Taifei; Wu Tao; Zhang Jirong; Han Lihong

    2012-01-01

    Objective: According to the regulations of nuclear safety rules and related standards, in-place test of the nuclear air-cleaning systems should be carried out before and during operation of the nuclear facilities, which ensure them to be in good condition. In some special conditions, the use of sample and injection manifolds is required to make the test tracer and ventilating duct air fully mixed, so as to get the on-spot typical sample. Methods: This paper introduces the technology and application of the sample and injection manifolds in nuclear air-cleaning system. Results: Multi point injection and multi point sampling technology as an effective experimental method, has been used in a of domestic and international nuclear facilities. Conclusion: The technology solved the problem of uniformly of on-spot injection and sampling,which plays an important role in objectively evaluating the function of nuclear air-cleaning system. (authors)

  15. Autologous blood versus corticosteroid local injection for treatment of Lateral Epicondylosis: A Randomized Clinical Trial

    Directory of Open Access Journals (Sweden)

    Ajit Singh,

    2013-08-01

    Full Text Available Objective: The objective of the present single blinded prospective randomized control trial was assessment of efficacy of autologous blood injection versus local steroid injection in treatment of lateral epicondylosis of elbow. Methodology: Using a pre-post experimental design, a total of sixty patients of previously untreated lateral epicondylosis were selected; Group 1 (n=30 was administered single injection of autologous blood and Group 2 (n=30 single local corticosteroid injection. Assessment was done at baseline, 2 weeks, 6 weeks and 12 weeks using PRTEE (Patient Rated Tennis Elbow Evaluation score. Results: Pre injection parameters showed no difference between groups (chi square test, p > 0.005. Analysis between groups showed significant decrease in steroid group at very short term - 2 weeks (unpaired t test, p < 0.005.There was no difference between groups at 6 weeks. There was a significant improvement in blood group at medium term -12 weeks (unpaired t test, p < 0.05. Conclusion: Both the interventions were effective in reducing pain and improving functional status of patients in short term, but autologous blood was more effective in longer run.

  16. FURNACE INJECTION OF ALKALINE SORBENTS FOR SULFURIC ACID REMOVAL

    Energy Technology Data Exchange (ETDEWEB)

    Gary M. Blythe

    2004-01-01

    The objective of this project has been to demonstrate the use of alkaline reagents injected into the furnace of coal-fired boilers as a means of controlling sulfuric acid emissions. The project was co-funded by the U.S. DOE National Energy Technology Laboratory under Cooperative Agreement DE-FC26-99FT40718, along with EPRI, the American Electric Power Company (AEP), FirstEnergy Corporation, the Tennessee Valley Authority, and Carmeuse North America. Sulfuric acid controls are becoming of increased interest for coal-fired power generating units for a number of reasons. In particular, sulfuric acid can cause plant operation problems such as air heater plugging and fouling, back-end corrosion, and plume opacity. These issues will likely be exacerbated with the retrofit of selective catalytic reduction (SCR) for NOX control, as SCR catalysts are known to further oxidize a portion of the flue gas SO{sub 2} to SO{sub 3}. The project tested the effectiveness of furnace injection of four different magnesium-based or dolomitic alkaline sorbents on full-scale utility boilers. These reagents were tested during one- to two-week tests conducted on two FirstEnergy Bruce Mansfield Plant (BMP) units. One of the sorbents tested was a magnesium hydroxide slurry byproduct from a modified Thiosorbic{reg_sign} Lime wet flue gas desulfurization process. The other three sorbents are available commercially and include dolomite, pressure-hydrated dolomitic lime, and commercially available magnesium hydroxide. The dolomite reagent was injected as a dry powder through out-of-service burners. The other three reagents were injected as slurries through air-atomizing nozzles inserted through the front wall of the upper furnace. After completing the four one- to two-week tests, the most promising sorbents were selected for longer-term (approximately 25-day) full-scale tests on two different units. The longer-term tests were conducted to confirm sorbent effectiveness over extended operation on two

  17. Short- and long-term efficacy of intra-articular injections with betamethasone as part of a treat-to-target strategy in early rheumatoid arthritis

    DEFF Research Database (Denmark)

    Hetland, Merete Lund; Østergaard, Mikkel; Ejbjerg, Bo

    2012-01-01

    To investigate the short-term and long-term efficacy of intra-articular betamethasone injections, and the impact of joint area, repeated injections, MRI pathology, anticyclic citrullinated peptide (CCP) and immunoglobulin M rheumatoid factor (IgM-RF) status in patients with early rheumatoid arthr...

  18. A HWIL test facility of infrared imaging laser radar using direct signal injection

    Science.gov (United States)

    Wang, Qian; Lu, Wei; Wang, Chunhui; Wang, Qi

    2005-01-01

    Laser radar has been widely used these years and the hardware-in-the-loop (HWIL) testing of laser radar become important because of its low cost and high fidelity compare with On-the-Fly testing and whole digital simulation separately. Scene generation and projection two key technologies of hardware-in-the-loop testing of laser radar and is a complicated problem because the 3D images result from time delay. The scene generation process begins with the definition of the target geometry and reflectivity and range. The real-time 3D scene generation computer is a PC based hardware and the 3D target models were modeled using 3dsMAX. The scene generation software was written in C and OpenGL and is executed to extract the Z-buffer from the bit planes to main memory as range image. These pixels contain each target position x, y, z and its respective intensity and range value. Expensive optical injection technologies of scene projection such as LDP array, VCSEL array, DMD and associated scene generation is ongoing. But the optical scene projection is complicated and always unaffordable. In this paper a cheaper test facility was described that uses direct electronic injection to provide rang images for laser radar testing. The electronic delay and pulse shaping circuits inject the scenes directly into the seeker's signal processing unit.

  19. Injection grout for deep repositories. Subproject 1: LowpH cementitious grout for larger fractures, leach testing of grout mixes and evaluation of the long-term safety

    International Nuclear Information System (INIS)

    Vuorinen, U.; Lehikoinen, J.; Imoto, Harutake; Yamamoto, Takeshi; Cruz Alonso, M.

    2005-10-01

    Constructing an underground disposal facility for spent nuclear fuel deep in bedrock requires lowpH cement-based injection grout, because assured data of the extent of a possible high-pH plume in saturated bedrock conditions is lacking. In this work low-pH grout mixes of new design were subjected to leach testing. Before chosen to leach testing the grout mixes had to fulfil certain technical requirements. Leach testing was performed in order to establish that the pH requirement (≤11) set for the leachates was met. For comparison reasons also one conventionally used cement based grout material was included in the tests. Two kinds of lowpH grout cement mixes were tested; mixes with added blast furnace slag (4 mixes) or added silica (6 mixes). All the mixes were not completely tested according to the test plan, because for some mixes during leach testing factors detrimental to the long-term safety of a repository were observed, e.g. too high pH or leached sulphide, which is harmful for copper. Leach testing of the grout mixes was performed in a glove-box (N 2 atmosphere) in order to avoid the interference of atmospheric CO 2 on the alkaline leachates. Two simulated groundwater solutions, saline OL-SO and fresh ALL-MR, were used as leachates. Two leach tests were applied; equilibrium and diffusion tests. In the equilibrium test at each measuring point only a part of the leachate was exchanged, whereas in the diffusion test the entire leachate was exchanged. The pH value of each leachate sample was measured, but total alkalinity was determined only for some leachates. Na, K, Ca, Mg, Al, Fe, Si, SO 4 2- , S TOT , and Cl were analysed in the leach solutions collected in the diffusion test of four grout mixes chosen. Also the corresponding solid specimens were analysed (SEM, XRD, EPMA, MIP, TG) in Japan. A few grout pore fluid pH values were measured in Spain, as well. The simplified thermodynamic model calculations were successful in qualitatively reproducing the

  20. Long-Term Effects of Botulinum Toxin Complex Type A Injection on Mechano- and Metabo-Sensitive Afferent Fibers Originating from Gastrocnemius Muscle.

    Directory of Open Access Journals (Sweden)

    Guillaume Caron

    Full Text Available The aim of the present study was to investigate long term effects of motor denervation by botulinum toxin complex type A (BoNT/A from Clostridium Botulinum, on the afferent fibers originating from the gastrocnemius muscle of rats. Animals were divided in 2 experimental groups: 1 untreated animals acting as control and 2 treated animals in which the toxin was injected in the left muscle, the latter being itself divided into 3 subgroups according to their locomotor recovery with the help of a test based on footprint measurements of walking rats: i no recovery (B0, ii 50% recovery (B50 and iii full recovery (B100. Then, muscle properties, metabosensitive afferent fiber responses to potassium chloride (KCl and lactic acid injections and Electrically-Induced Fatigue (EIF, and mechanosensitive responses to tendon vibrations were measured. At the end of the experiment, rats were killed and the toxin injected muscles were weighted. After toxin injection, we observed a complete paralysis associated to a loss of force to muscle stimulation and a significant muscle atrophy, and a return to baseline when the animals recover. The response to fatigue was only decreased in the B0 group. The responses to KCl injections were only altered in the B100 groups while responses to lactic acid were altered in the 3 injected groups. Finally, our results indicated that neurotoxin altered the biphasic pattern of response of the mechanosensitive fiber to tendon vibrations in the B0 and B50 groups. These results indicated that neurotoxin injection induces muscle afferent activity alterations that persist and even worsen when the muscle has recovered his motor activity.

  1. Long-Term Effects of Botulinum Toxin Complex Type A Injection on Mechano- and Metabo-Sensitive Afferent Fibers Originating from Gastrocnemius Muscle.

    Science.gov (United States)

    Caron, Guillaume; Marqueste, Tanguy; Decherchi, Patrick

    2015-01-01

    The aim of the present study was to investigate long term effects of motor denervation by botulinum toxin complex type A (BoNT/A) from Clostridium Botulinum, on the afferent fibers originating from the gastrocnemius muscle of rats. Animals were divided in 2 experimental groups: 1) untreated animals acting as control and 2) treated animals in which the toxin was injected in the left muscle, the latter being itself divided into 3 subgroups according to their locomotor recovery with the help of a test based on footprint measurements of walking rats: i) no recovery (B0), ii) 50% recovery (B50) and iii) full recovery (B100). Then, muscle properties, metabosensitive afferent fiber responses to potassium chloride (KCl) and lactic acid injections and Electrically-Induced Fatigue (EIF), and mechanosensitive responses to tendon vibrations were measured. At the end of the experiment, rats were killed and the toxin injected muscles were weighted. After toxin injection, we observed a complete paralysis associated to a loss of force to muscle stimulation and a significant muscle atrophy, and a return to baseline when the animals recover. The response to fatigue was only decreased in the B0 group. The responses to KCl injections were only altered in the B100 groups while responses to lactic acid were altered in the 3 injected groups. Finally, our results indicated that neurotoxin altered the biphasic pattern of response of the mechanosensitive fiber to tendon vibrations in the B0 and B50 groups. These results indicated that neurotoxin injection induces muscle afferent activity alterations that persist and even worsen when the muscle has recovered his motor activity.

  2. UV-visible digital imaging of split injection in a Gasoline Direct Injection engine

    Directory of Open Access Journals (Sweden)

    Merola Simona Silvia

    2015-01-01

    Full Text Available Ever tighter limits on pollutant emissions and the need to improve energy conversion efficiency have made the application of gasoline direct injection (GDI feasible for a much wider scale of spark ignition engines. Changing the way fuel is delivered to the engine has thus provided increased flexibility but also challenges, such as higher particulate emissions. Therefore, alternative injection control strategies need to be investigated in order to obtain optimum performance and reduced environmental impact. In this study, experiments were carried out on a single-cylinder GDI optical engine fuelled with commercial gasoline in lean-burn conditions. The single-cylinder was equipped with the head of a commercial turbocharged engine with similar geometrical specifications (bore, stroke, compression ratio and wall guided fuel injection. Optical accessibility was ensured through a conventional elongated hollow Bowditch piston and an optical crown, accommodating a fused-silica window. Experimental tests were performed at fixed engine speed and injection pressure, whereas the injection timing and the number of injections were adjusted to investigate their influence on combustion and emissions. UV-visible digital imaging was applied in order to follow the combustion process, from ignition to the late combustion phase. All the optical data were correlated with thermodynamic analysis and measurements of exhaust emissions. Split injection strategies (i.e. two injections per cycle with respect to single injection increased combustion efficiency and stability thanks to an improvement of fuel air mixing. As a consequence, significant reduction in soot formation and exhaust emission with acceptable penalty in terms of HC and NOx were measured.

  3. [Application of injection test in confirming the ideal position of esophageal balloon catheter].

    Science.gov (United States)

    Chen, Han; Xu, Ming; Yang, Yanlin; He, Xuan; Zhou, Jianxin

    2017-09-01

    To evaluate the safety and feasibility of injection test which is used to locate esophageal balloon catheter. A prospective study was conducted. The patients undergoing invasive mechanical ventilation (MV) admitted to general intensive care unit (ICU) of Beijing Tiantan Hospital Affiliated to Capital Medical University from May 2015 and March 2017 were enrolled. The commercially available esophageal balloon catheter was modified to perform injection test. The catheter was withdrawn step by step and the injection test was repeated until the presence disturbance wave presented, which indicated that the balloon had just entered the esophagus. The position where disturbance wave appears was named 0 cm. End-expiratory occlusions were performed at the positions of +15, +10, +5, 0, -5, -10 and -15 cm, respectively, and the changes of esophageal pressure (Pes) and airway pressures (Paw) were measured in the spontaneous breathing and passive ventilation, and the ratio between the changes (ΔPes/ΔPaw) was calculated. A total of 20 patients were enrolled, of which 15 patients finished both the spontaneous and the passive ventilation parts, and 2 patients finished only the spontaneous part and 3 patients finished only passive part. (1) Disturbance waves could be induced by injection test in all patients. The average depth of disturbance wave in spontaneous breathing was deeper than that in passive ventilation (cm: 42.4±3.8 vs. 41.8±3.3), but there was no significant difference between the two ventilation settings (P = 0.132). No adverse events occurred during the study period. (2) Pes increased with the stepwise withdraw of esophageal catheter, reached the maximal value at +5 cm, and then decreased when the catheter was further withdrawn, no matter in the spontaneous or the passive ventilation. In spontaneous breathing, the ΔPes/ΔPaw was within the ideal range (0.8-1.2) at the positions of 0, -5 and -10 cm. The ΔPes/ΔPaw was closest to unity at the positions of 0 cm (0

  4. Vocal Fold Augmentation with Injectable Polycaprolactone Microspheres/Pluronic F127 Hydrogel: Long-Term In Vivo Study for the Treatment of Glottal Insufficiency

    Science.gov (United States)

    Kwon, Seong Keun; Kim, Hee-Bok; Song, Jae-Jun; Cho, Chang Gun; Park, Seok-Won; Choi, Jong-Sun; Ryu, Junsun; Oh, Se Heang; Lee, Jin Ho

    2014-01-01

    There is increasing demand for reconstruction of glottal insufficiency. Several injection materials have been examined for this purpose, but all had limitations, such as poor long-term durability, migration from the injection site, inflammation, granuloma formation, and interference with vocal fold vibration due to viscoelastic mismatch. Here, we developed a novel injection material, consisting of polycaprolactone (PCL) microspheres, which exhibits better viscoelasticity than conventional materials, and Pluronic F127 carrier, which decreases the migration of the injection materials. The material was injected into rabbits with glottal insufficiency and compared with the FDA-approved injection material, calcium hydroxylapatite (CaHA). Endoscopic and histological examinations indicated that PCL/Pluronic F127 remained at the injection site with no inflammatory response or granuloma formation, whereas CaHA leaked out and migrated from the injection site. Therefore, vocal fold augmentation was almost completely retained during the 12-month follow-up period in this study. Moreover, induced phonation and high-speed recording of vocal fold vibration showed decreased vocal fold gap area in the PCL/Pluronic F127 group. Our newly developed injection material, PCL/Pluronic F127, permits efficient augmentation of paralyzed vocal fold without complications, a concept that can be applied clinically, as demonstrated by the successful long-term follow-up. PMID:24465582

  5. Verification test for radiation reduction effect and material integrity on PWR primary system by zinc injection

    Energy Technology Data Exchange (ETDEWEB)

    Kawakami, H.; Nagata, T.; Yamada, M. [Nuclear Power Engineering Corp. (Japan); Kasahara, K.; Tsuruta, T.; Nishimura, T. [Mitsubishi Heavy Industries, Ltd. (Japan); Ishigure, K. [Saitama Inst. of Tech. (Japan)

    2002-07-01

    Zinc injection is known to be an effective method for the reduction of radiation source in the primary water system of a PWR. There is a need to verify the effect of Zn injection operation on radiation source reduction and materials integrity of PWR primary circuit. In order to confirm the effectiveness of Zn injection, verification test as a national program sponsored by Ministry of Economy, Trade and Industry (METI) was started in 1995 for 7-year program, and will be finished by the end of March in 2002. This program consists of irradiation test and material integrity test. Irradiation test as an In-Pile-Test managed by AEAT Plc(UK) was performed using the LVR-15 reactor of NRI Rez in Check Republic. Furthermore, Out-of-Pile-Test using film adding unit was also performed to obtain supplemental data for In-Pile-Test at Takasago Engineering Laboratory of NUPEC. Material Integrity test was planned to perform constant load test, constant strain test and corrosion test at the same time using large scale Loop and slow strain extension rate testing (SSRT) at Takasago Engineering Laboratory of NUPEC. In this paper, the results of the verification test for Zinc program at present are discussed. (authors)

  6. An evaluation of a new N-isopropyl-p-[123I] iodoamphetamine double injection method for acetazolamide testing

    International Nuclear Information System (INIS)

    Mori, Kentaro; Maeda, Minoru; Asegawa, Satoshi; Masuda, Yoko.

    1994-01-01

    To evaluate the capacity of the cerebrovascular reserve, the acetazolamide test must be used to quantitatively measure the cerebral blood flow (CBF) before and after the administration of acetazolamide. Previously, the authors have explained the rationale for using 5 min SPECT images to quantify the CBF with N-isoprophyl-p-[ 123 I] iodoamphetamine ( 123 I-IMP), and in this study they describe how they devised a 123 I-IMP double injection method for use with the acetazolamide test, and report on the clinical results. First, We measured the brain and arterial 123 I concentrations 10 normal subjects after a 123 I-IMP injection, and noted that after 25 minutes the brain and arterial blood activity had plateaued and stabilized. Thus, by using the background substraction method, We found it possible to quantitatively measure the CBF twice in 30 minutes and have called this technique the double injection method. We have clinically used this double injection method for evaluating the CBF in 5 lacunar stroke patients with no major arterial occlusion and found no statistically significant difference in the CBF values between the first and second CBF measurements. They then applied this double injection method for the acetazolamide testing of 10 stroke patients with an arterial occlusion of stenosis and found that the CBF results compared favorably with the CBF results achieved with the use of the separate injection method. It also should be noted the double injection method was successfully used for clinical CBF measurements without acetazolamide testing. (author)

  7. A field test of a waste containment technology using a new generation of injectable barrier liquids

    International Nuclear Information System (INIS)

    Moridis, G.; Apps, J.; Persoff, P.; Myer, L.; Muller, S.; Pruess, K.; Yen, P.

    1996-08-01

    A first stage field injection of a new generation of barrier liquids was successfully completed. Two types of barrier liquids, colloidal silica (CS) and polysiloxane (PSX), were injected into heterogeneous unsaturated deposits of sand, silt, and gravel typical of many of the arid DOE cleanup sites and particularly analogous to the conditions of the Hanford Site. Successful injection by commercially available chemical grouting equipment and the tube-a-manchette technique was demonstrated. Excavation of the grout bulbs permitted visual evaluation of the soil permeation by the grout, as well as sample collection. Both grouts effectively permeated all of the formation. The PSX visually appeared to perform better, producing a more uniform and symmetric permeation regardless of heterogeneity, filling large as well as small pores and providing more structural strength than the CS. Numerical simulation of the injection tests incorporated a stochastic field to represent site heterogeneity and was able to replicate the general test behavior. Tiltmeters were used successfully to monitor surface displacements during grout injection

  8. Summary of air permeability data from single-hole injection tests in unsaturated fractured tuffs at the Apache Leap Research Site: Results of steady-state test interpretation

    International Nuclear Information System (INIS)

    Guzman, A.G.; Geddis, A.M.; Henrich, M.J.; Lohrstorfer, C.F.; Neuman, S.P.

    1996-03-01

    This document summarizes air permeability estimates obtained from single hole pneumatic injection tests in unsaturated fractured tuffs at the Covered Borehole Site (CBS) within the larger apache Leap Research Site (ALRS). Only permeability estimates obtained from a steady state interpretation of relatively stable pressure and flow rate data are included. Tests were conducted in five boreholes inclined at 45 degree to the horizontal, and one vertical borehole. Over 180 borehole segments were tested by setting the packers 1 m apart. Additional tests were conducted in segments of lengths 0.5, 2.0, and 3.0 m in one borehole, and 2.0 m in another borehole, bringing the total number of tests to over 270. Tests were conducted by maintaining a constant injection rate until air pressure became relatively stable and remained so for some time. The injection rate was then incremented by a constant value and the procedure repeated. The air injection rate, pressure, temperature, and relative humidity were recorded. For each relatively stable period of injection rate and pressure, air permeability was estimated by treating the rock around each test interval as a uniform, isotropic porous medium within which air flows as a single phase under steady state, in a pressure field exhibiting prolate spheroidal symmetry. For each permeability estimate the authors list the corresponding injection rate, pressure, temperature and relative humidity. They also present selected graphs which show how the latter quantities vary with time; logarithmic plots of pressure versus time which demonstrate the importance of borehole storage effects during the early transient portion of each incremental test period; and semilogarithmic plots of pressure versus recovery time at the end of each test sequence

  9. Test of safety injection supply by diesel generator under reactor vessel closed condition

    International Nuclear Information System (INIS)

    Zhang Hao; Bi Fengchuan; Che Junxia; Zhang Jianwen; Yang Bo

    2014-01-01

    The paper studied that the test of diesel generator full load take-up under the condition of actual safety injection and reactor vessel closed in Ningde nuclear project unit l. It is proved that test result accorded with design criteria, meanwhile, the test was removed from the key path of project schedule, which cut a huge cost. (authors)

  10. Prediction of the Long Term Cooling Performance for the 3-Pin Fuel Test Loop

    Energy Technology Data Exchange (ETDEWEB)

    Park, S. K.; Chi, D. Y.; Sim, B. S.; Park, K. N.; Ahn, S. H.; Lee, J. M.; Lee, C. Y.; Kim, H. R

    2005-12-15

    In the long term cooling phase that the emergency cooling water injection ends, the performance of the residual heat removal for the 3-pin fuel test loop has been predicted by a simplified heat transfer model. In the long term cooling phase the residual heat is 1323W for PWR fuel test mode and 1449W for CANDU fuel test mode. The each residual heat is assumed as 2% of the fission power of the test fuel used in the anticipated operational occurrence and design basis accident analyses. The each fission power used for the analyses is 105% of the rated fission power in the normal operation. In the long term cooling phase the residual heat is removed to the HANARO pool through the double pressure vessels of the in-pile test section. Saturate pooling boiling is assumed on the test fuel and condensation heat transfer is expected on the inner wall of the fuel carrier and the flow divider. Natural convection heat transfer on a heated vertical wall is also assumed on the outer wall of the outer pressure vessel. The conduction heat transfer is only considered in the gap between the double pressure vessels charged with neon gas and in the downcomer filled with coolant. The heat transfer rate between the coolant temperature of 152 .deg. C in the in-pile test section and the water temperature of 45 .deg. C in the HANARO pool is predicted as about 1666W. The 152 .deg. C is the saturate temperature of the coolant pressure predicted from the MARS code. The cooling capacity of 1666W is greater than the residual heats of 1323W and 1449W. Consequently the long term cooling performance of the 3-pin fuel test loop is sufficient for the anticipated operational occurrences and design basis accidents.

  11. Pilot test of pressure maintenance by water injection and gas injection in the M'Bega field

    Energy Technology Data Exchange (ETDEWEB)

    Hodee, B

    1965-02-01

    The M'Bega reservoir, Gabon, is one that is both fractured and fissured, and its reservoir rock, improperly referred to as silicified clay, is made up of opal-cement silt. At the time it began production, the major unknown factor in this field was the amount of oil it contained. The factor was finally determined after 18 mo. of production, once data was obtained concerning the advance of aquifiers. Up until that time, applied comparisons of successive data could not differentiate between the activity of aquifers and that of dissolved gas expansion with partial segregation. Consequently, a pilot test was made in which pressure was maintained by water injection. Then, with a double drainage phenomena (the tops by the gas, and the flanks by the aquifer water), production of the field consisted of bringing about a coincidence between the water and gas fronts at the level of the existing wells by means of gas injection.

  12. Fibrous Myopathy as a Complication of Repeated Intramuscular Injections for Chronic Headache

    Directory of Open Access Journals (Sweden)

    R Burnham

    2006-01-01

    Full Text Available Two cases of fibrous myopathy associated with repeated, long-term intramuscular injections for treatment of chronic temporomandibular joint pain and chronic headache, respectively, are described. Both patients developed severe, function-limiting contractures in upper and lower extremity muscles used as injection sites. In one of the cases, the contractures were painful. Electrophysiological testing, magnetic resonance imaging and muscle biopsy results were all consistent with myopathy and replacement of skeletal muscle with noncontractile fibrous tissue. These cases are presented to increase awareness of fibrous myopathy and to promote surveillance for this serious potential complication of long-term intramuscular injections in chronic headache and other pain patients.

  13. Shortlasting Unilateral Neuralgiform Conjunctival Injection and Tearing Syndrome: The Term and New View Points

    Science.gov (United States)

    Antonaci, Fabio; Fredriksen, Torbjørn; Pareja, Juan A.; Sjaastad, Ottar

    2018-01-01

    A solitary patient with symptoms similar to those of shortlasting unilateral neuralgiform conjunctival injection and tearing (SUNCT) was first mentioned in 1978. The term SUNCT was first used in 1991. SUNCT is an acronym; the “S” signifies “Shortlasting”; the “U” symbolizes “Unilateral”; “N” stands for “Neuralgiform”; the “C” for “Conjunctival injection”; and “T” for “Tearing.” The term short-lasting unilateral neuralgiform headache attacks with cranial autonomic symptoms were marketed in 2004. The terminology and new view points are discussed and nosography proposal for SUNCT is presented. PMID:29740387

  14. Additional short-term plutonium urinary excretion data from the 1945-1947 plutonium injection studies

    International Nuclear Information System (INIS)

    Moss, W.D.; Gautier, M.A.

    1985-01-01

    A review of original injection experimental records at LASL suggest that the power function fit is a good choice to describe early plutonium excretion; however, the later period (300-, 500-, and 1600-day) results along with 10,000 day results show a significant departure from the Langham power function model used to describe long-term Pu excretion. The authors suggest that since the 523- and 1600-day data in question influenced the mathematical development of the Langham power function equation, its use in predicting Pu body burdens from long-term excretion data should be discouraged. 9 references, 2 figures, 2 tables

  15. Long-term efficacy and safety of self-intracavernous injection of prostaglandin E1 for treatment of erectile dysfunction in China.

    Science.gov (United States)

    He, L; Wen, J; Jiang, X; Chen, H; Tang, Y

    2011-06-01

    The study evaluated the long-term efficacy and safety profiles of self-intracavernous injection of prostaglandin E1 (PGE1) for erectile dysfunction (ED). Four hundred and sixteen ED patients were treated with self-intracavernous injection of PGE1 from January 1998 to December 2007 in our outpatient service. Follow-up was made to investigate the efficacy and side effects of this treatment. It was found that 261 patients (62.7%) felt satisfied and kept using this treatment due to its advantages of satisfactory efficacy and reasonable expense. Twenty-seven of them (6.5%) got rid of PGE1 treatment after five times injections and did not need any other drugs to maintain satisfactory sexual lives. Two hundred and fourteen (51.4%) patients kept using this treatment for over 1 year, 26 (6.2%) over 5 years, 12 (2.9%) over 8 years and 7 (1.7%) over 10 years. The major complications of self-intracavernous injection of PGE1 include fibrosis of corpus cavernosum (three cases), ecchymosis associated with vascular injury due to injection (23 cases) and pain associated with injection (295 cases). There were no patients displaying priapism. It is concluded that self-intracavernous injection of PGE1 is a safe and effective treatment for ED with various aetiologies and a broad range of severity, and no serious complications were observed after long-term application. © 2011 Blackwell Verlag GmbH.

  16. Dominant lethal tests of male mice given 239Pu salt injections

    International Nuclear Information System (INIS)

    Luening, K.G.; Froelen, H.; Nilsson, A.

    1976-01-01

    To study the possible genetic effects of 239 Pu manifesting in dominant lethals, five test series (E1-E5) were performed. Males from an inbred CBA strain were given 239 Pu salt injections intravenously and mated weekly to 3 CBA females each for 12 to 24 weeks. Some interruptions in the mating scheme were made. For the first two test series (E1, E2) 239 Pu nitrate solution and 239 Pu citrate, used in E3-E5, were prepared. The solution was millipore filtered just prior to injection. Among a total of 10255 implants sired by males given Pu-nitrate in E1 and E2 no significant excess of intra-uterine death relative to 7216 control implants occurred. Test series E3-E5 with 60 males each, used three groups of 20, with one control group. In E3, 0.5 μCi and 0.1 μCi were given per male/group, respectively; in E4 and E5, 0.25 μCi and 0.05 μCi, respectively. The males given 0.5 μCi in E3 became successively sterile from the 7th week. The results in E3-E5 point in the same direction with significant excess of intra-uterine death in E3 and E5. In E4 the females from matings from the 9th, 14th and 16th week, and in E5 females from the 9th week, were allowed to litter to give F 1 offspring. Dominant lethal tests of F 1 males gave concordant results in all four samples, showing significantly excessive death in offspring to F 1 males whose fathers had received Pu. The excessive death was evenly distributed and did not indicate the presence of semisterile F 1 males. In tests of Pu-injected males and of F 1 males a remarkable excess of death in late stages of foetal development was observed. Such effects had never before been observed in this CBA strain in tests of extrinsic and intrinsic exposure to ionizing irradiation

  17. Intracoronary Injection of CD34-Cells in Chronic Ischemic Heart Failure

    DEFF Research Database (Denmark)

    Hansen, Morten; Nyby, Sebastian; Eifer Møller, Jacob

    2014-01-01

    Objectives: Seven years ago, the DanCell study was carried out to test the hypothesis of improvement in left ventricular ejection fraction (LVEF) following repeated intracoronary injections of autologous bone marrow-derived stem cells (BMSCs) in patients suffering from chronic ischemic heart...... was significantly associated with survival (hazard ratio: 0.90, 95% CI: 0.82-1.00, p = 0.04). Conclusions: Intracoronary injections of a high number of CD34(+) cells may have a beneficial effect on chronic ischemic heart failure in terms of long-term survival. © 2014 S. Karger AG, Basel....

  18. Intermediate Scale Laboratory Testing to Understand Mechanisms of Capillary and Dissolution Trapping during Injection and Post-Injection of CO2 in Heterogeneous Geological Formations

    Energy Technology Data Exchange (ETDEWEB)

    Illangasekare, Tissa [Colorado School of Mines, Golden, CO (United States); Trevisan, Luca [Colorado School of Mines, Golden, CO (United States); Agartan, Elif [Colorado School of Mines, Golden, CO (United States); Mori, Hiroko [Colorado School of Mines, Golden, CO (United States); Vargas-Johnson, Javier [Colorado School of Mines, Golden, CO (United States); Gonzalez-Nicolas, Ana [Colorado School of Mines, Golden, CO (United States); Cihan, Abdullah [Colorado School of Mines, Golden, CO (United States); Birkholzer, Jens [Colorado School of Mines, Golden, CO (United States); Zhou, Quanlin [Colorado School of Mines, Golden, CO (United States)

    2015-03-31

    Carbon Capture and Storage (CCS) represents a technology aimed to reduce atmospheric loading of CO2 from power plants and heavy industries by injecting it into deep geological formations, such as saline aquifers. A number of trapping mechanisms contribute to effective and secure storage of the injected CO2 in supercritical fluid phase (scCO2) in the formation over the long term. The primary trapping mechanisms are structural, residual, dissolution and mineralization. Knowledge gaps exist on how the heterogeneity of the formation manifested at all scales from the pore to the site scales affects trapping and parameterization of contributing mechanisms in models. An experimental and modeling study was conducted to fill these knowledge gaps. Experimental investigation of fundamental processes and mechanisms in field settings is not possible as it is not feasible to fully characterize the geologic heterogeneity at all relevant scales and gathering data on migration, trapping and dissolution of scCO2. Laboratory experiments using scCO2 under ambient conditions are also not feasible as it is technically challenging and cost prohibitive to develop large, two- or three-dimensional test systems with controlled high pressures to keep the scCO2 as a liquid. Hence, an innovative approach that used surrogate fluids in place of scCO2 and formation brine in multi-scale, synthetic aquifers test systems ranging in scales from centimeter to meter scale developed used. New modeling algorithms were developed to capture the processes controlled by the formation heterogeneity, and they were tested using the data from the laboratory test systems. The results and findings are expected to contribute toward better conceptual models, future improvements to DOE numerical codes, more accurate assessment of storage capacities, and optimized placement strategies. This report presents the experimental and modeling methods

  19. Kepler Planet Detection Metrics: Per-Target Flux-Level Transit Injection Tests of TPS for Data Release 25

    Science.gov (United States)

    Burke, Christopher J.; Catanzarite, Joseph

    2017-01-01

    Quantifying the ability of a transiting planet survey to recover transit signals has commonly been accomplished through Monte-Carlo injection of transit signals into the observed data and subsequent running of the signal search algorithm (Gilliland et al., 2000; Weldrake et al., 2005; Burke et al., 2006). In order to characterize the performance of the Kepler pipeline (Twicken et al., 2016; Jenkins et al., 2017) on a sample of over 200,000 stars, two complementary injection and recovery tests are utilized:1. Injection of a single transit signal per target into the image or pixel-level data, hereafter referred to as pixel-level transit injection (PLTI), with subsequent processing through the Photometric Analysis (PA), Presearch Data Conditioning (PDC), Transiting Planet Search (TPS), and Data Validation (DV) modules of the Kepler pipeline. The PLTI quantification of the Kepler pipeline's completeness has been described previously by Christiansen et al. (2015, 2016); the completeness of the final SOC 9.3 Kepler pipeline acting on the Data Release 25 (DR25) light curves is described by Christiansen (2017).2. Injection of multiple transit signals per target into the normalized flux time series data with a subsequent transit search using a stream-lined version of the Transiting Planet Search (TPS) module. This test, hereafter referred to as flux-level transit injection (FLTI), is the subject of this document. By running a heavily modified version of TPS, FLTI is able to perform many injections on selected targets and determine in some detail which injected signals are recoverable. Significant numerical efficiency gains are enabled by precomputing the data conditioning steps at the onset of TPS and limiting the search parameter space (i.e., orbital period, transit duration, and ephemeris zero-point) to a small region around each injected transit signal.The PLTI test has the advantage that it follows transit signals through all processing steps of the Kepler pipeline, and

  20. Designing a Prototype LPG Injection Electronic Control Unit for a Carburetted Gasoline Engine

    Directory of Open Access Journals (Sweden)

    Barış ERKUŞ

    2015-07-01

    Full Text Available In this study, the originally carburetted gasoline engine was converted to gas-phase liquefied petroleum gas (LPG injection engine by using an after market LPG conversion kit's components except the electronic control unit (ECU. Instead of after market LPG injection ECU, the ECU which was designed considering the effects of  electromagnetic interference (EMI, was used for controlling injection. The designed ECU was tested in terms of EMI while the engine was being run and it was detected that the EMI noises could be suppressed as possible by taken measures. Designed ECU was used in performance tests at different engine conditions and the results obtained with LPG injection were compared with the results obtained with LPG carburetion. According to the performance test results, LPG injection ECU designed in this study could help to achieve low exhaust emissions and high engine performance.  

  1. Validation of precision powder injection molding process simulations using a spiral test geometry

    DEFF Research Database (Denmark)

    Marhöfer, Maximilian; Müller, Tobias; Tosello, Guido

    2015-01-01

    Like in many other areas of engineering, process simulations find application in precision injection molding to assist and optimize the quality and design of precise products and the molding process. Injection molding comprises mainly the manufacturing of plastic components. However, the variant ....... The necessary data and the implementation procedure of the new material models are outlined. In order to validate the simulation studies and evaluate their accuracy, the simulation results are compared with experiments performed using a spiral test geometry...... for powder injection molding. This characterization includes measurements of rheological, thermal, and pvT behavior of the powder-binder-mixes. The acquired material data was used to generate new material models for the database of the commercially available Autodesk Moldflow® simulation software...

  2. Gas injection test in a borehole of the Meuse/Haute Marne underground research laboratory: experimental overview and basic data analysis

    International Nuclear Information System (INIS)

    La Vaissiere, Remi de; Talandier, Jean; Piedevache, Mederic; Helmlinger, Benjamin; Lavanchy, Jean-Marc; Croise, Jean; Senger, Rainer

    2012-01-01

    Document available in extended abstract form only. Understanding of the fate and of the impact of gas produced by corrosion of metals, microbial degradation and the radiolysis of water within a deep geological disposal repository for radioactive waste, is of major relevance in the performance assessment including the long-term evolution of the repository. To address these issues, the French national Agency for the management of radioactive waste (Andra) has directed a field scale experiment examining the mechanisms controlling gas entry and gas migration in the Callovo-Oxfordian (COX) clay, the proposed host rock of the French deep geological repository project. This experiment, called PGZ1, studies the migration of nitrogen in the COX based on gas injection tests performed in a borehole of the Meuse/Haute Marne URL. This experiment is currently being performed under the auspices of the Euratom 7. Framework FORGE project. In this poster, we provide an overview on the field data and a basic analysis of the data. The advanced interpretation of the data was based on numerical modeling of the two-phase flow with 3 different approaches and numerical codes. The experimental layout consists of three boreholes. Two parallel boreholes (PGZ1201 and PGZ1202) were drilled from the GED drift and are equipped with a triple interval system to monitor the pressure evolutions in 3 intervals, associated with the hydraulic and gas injection tests in the selected test interval (PGZ1201, middle interval). The third borehole (PGZ1031) was drilled from the GEX drift and is equipped with an extensometer probe, to monitor potential deformation associated with the resulting stress changes. An initial hydraulic test (HYDRO1) was performed in the test interval to estimate the hydraulic conductivity of the COX prior to gas testing. The hydraulic test consisted in a sequence of injections of synthetic formation water (pressure pulse followed by a constant pressure and a final shut-in phase

  3. Enhancement effects of test injection with a small amount of MR contrast medium in the oral and maxillofacial region

    International Nuclear Information System (INIS)

    Yanagi, Yoshinobu; Asaumi, Jun-ichi; Konouchi, Hironobu; Hisatomi, Miki; Matsuzaki, Hidenobu; Murakami, Jun; Maki, Yuu; Unetsubo, Teruhisa; Kishi, Kanji

    2006-01-01

    Purpose: To examine whether the signal intensity of dynamic contrast-enhanced MRI (DCE-MRI) is altered by test injection of 1 ml of contrast medium, and if so, whether this change affects the DCE-MRI analysis. Materials and methods: Six healthy volunteers were examined by DCE-MRI using a Magnevist syringe and/or an Omniscan syringe for the injection of contrast medium. Each scan was performed 10 times using steady-state free precession (3D-FISP), a sequence for DCE-MRI, before and after intravenous injection of 1 ml of the contrast medium. The internal pterygoid muscle, masseter muscle, tongue, parotid gland, submandibular gland, bone marrow of the mandible, subcutaneous adipose tissue, and common carotid artery were determined to be regions of interest (ROI), and the ROI internal average signal intensity was measured. The 10 data sets obtained before or after contrast medium administration for each ROI were evaluated using the paired t-test. Results: The test injection increased the signal intensities of six of eight ROIs, with all 20 experiments in the submandibular gland showing significant differences. There was no significant difference in the two ROIs corresponding to the carotid artery and subcutaneous adipose tissue of the cheek. Conclusions: The enhanced signal intensity in the tissue might have been caused by the small amount of contrast medium in the test injection. To eliminate this discrepancy caused by the test injection, a pre-contrast scan should be performed when the average signal intensity of an ROI is measured. We therefore believe that the data obtained before a test injection may be important in the analysis of DCE-MRI

  4. Short-term disposition of TCDD in rats after iv injection

    International Nuclear Information System (INIS)

    Ernst, S.W.; Weber, L.W.D.; Rozman, K.; Stahl, B.U.

    1990-01-01

    Male Sprague-Dawley rats (235-290gr) were injected iv via tail vein with 14 C-TCDD (10 μg/kg, 1 μCi/kg) in a 10% oil/water emulsion (4 ml/kg). 4 rats per group were sacrificed 5, 15 or 45 minutes and 3, 8 or 24 hours after dosing. TCDD attained highest radioactivity levels immediately after injection in blood and in tissues with high blood flow such as lung, spleen, heart, olfactory epithelium (maximum at 5 min post injection), brown adipose tissue and muscle (15 min). At 5 min these tissues accounted for about 30% of total radioactivity. The disposition profile of 14 C-radioactivity was 1st order biphasic with the first phase lasting less than 3 hrs. After this time radioactivity levels in blood were lowest of all tissues. Low-perfused tissues such as skin and white adipose tissue (WAT) displayed distinct uptake phases with peak levels of radioactivity occurring after 8 and 24 hours, respectively. Liver, a major target and storage organ of TCDD toxicity, reached 80% of maximum within 45 min and maximum by 8 hours; about 45% of dose were associated with liver tissue at these time points. This is consistent with a two-phase short-term tissue distribution of TCDD. During the first phase most of the TCDD dissolved in oil spheres distributed into highly perfused organs; during the following phase it was redistributed to poorly perfused, but rather lipophilic organs. Two tissues did not fit this pattern. Liver, highly perfused but lower in fat content than WAT, accumulated about one-half of total TCDD which is known to be bound to microsomal proteins. Brain, despite its high blood supply and lipophilicity, attained concentrations of TCDD comparable only to or even lower than in blood. This is surprising because it is in contrast to the disposition of other compounds with similar physicochemical properties

  5. 300 Area Uranium Stabilization Through Polyphosphate Injection: Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Vermeul, Vincent R.; Bjornstad, Bruce N.; Fritz, Brad G.; Fruchter, Jonathan S.; Mackley, Rob D.; Newcomer, Darrell R.; Mendoza, Donaldo P.; Rockhold, Mark L.; Wellman, Dawn M.; Williams, Mark D.

    2009-06-30

    The objective of the treatability test was to evaluate the efficacy of using polyphosphate injections to treat uranium-contaminated groundwater in situ. A test site consisting of an injection well and 15 monitoring wells was installed in the 300 Area near the process trenches that had previously received uranium-bearing effluents. This report summarizes the work on the polyphosphate injection project, including bench-scale laboratory studies, a field injection test, and the subsequent analysis and interpretation of the results. Previous laboratory tests have demonstrated that when a soluble form of polyphosphate is injected into uranium-bearing saturated porous media, immobilization of uranium occurs due to formation of an insoluble uranyl phosphate, autunite [Ca(UO2)2(PO4)2•nH2O]. These tests were conducted at conditions expected for the aquifer and used Hanford soils and groundwater containing very low concentrations of uranium (10-6 M). Because autunite sequesters uranium in the oxidized form U(VI) rather than forcing reduction to U(IV), the possibility of re-oxidation and subsequent re-mobilization is negated. Extensive testing demonstrated the very low solubility and slow dissolution kinetics of autunite. In addition to autunite, excess phosphorous may result in apatite mineral formation, which provides a long-term source of treatment capacity. Phosphate arrival response data indicate that, under site conditions, the polyphosphate amendment could be effectively distributed over a relatively large lateral extent, with wells located at a radial distance of 23 m (75 ft) reaching from between 40% and 60% of the injection concentration. Given these phosphate transport characteristics, direct treatment of uranium through the formation of uranyl-phosphate mineral phases (i.e., autunite) could likely be effectively implemented at full field scale. However, formation of calcium-phosphate mineral phases using the selected three-phase approach was problematic. Although

  6. Short Term Analgesic Effects of 5% Dextrose Epidural Injections for Chronic Low Back Pain: A Randomized Controlled Trial.

    Science.gov (United States)

    Maniquis-Smigel, Liza; Dean Reeves, Kenneth; Jeffrey Rosen, Howard; Lyftogt, John; Graham-Coleman, Cassie; Cheng, An-Lin; Rabago, David

    2017-02-01

    Hypertonic dextrose injection (prolotherapy) is reported to reduce pain including non-surgical chronic low back pain (CLBP), and subcutaneous injection of 5% dextrose is reported to reduce neurogenic pain, hyperalgesia and allodynia. The mechanism in both cases is unclear, though a direct effect of dextrose on neurogenic pain has been proposed. This study assessed the short-term analgesic effects of epidural 5% dextrose injection compared with saline for non-surgical CLBP. Randomized double-blind (injector, participant) controlled trial. Adults with moderate-to-severe non-surgical low back pain with radiation to gluteal or leg areas for at least 6 months received a single epidurogram-confirmed epidural injection of 10 mL of 5% dextrose or 0.9% saline using a published vertical caudal injection technique. The primary outcome was change in a numerical rating scale (NRS, 0 - 10 points) pain score between baseline and 15 minutes; and 2, 4, and 48 hours and 2 weeks post-injection. The secondary outcome was percentage of participants achieving 50% or more pain improvement at 4 hours. No baseline differences existed between groups; 35 participants (54 ± 10.7 years old; 11 female) with moderate-to-severe CLBP (6.7 ± 1.3 points) for 10.6 ± 10.5 years. Dextrose participants reported greater NRS pain score change at 15 minutes (4.4 ± 1.7 vs 2.4 ± 2.8 points; P = 0.015), 2 hours (4.6 ± 1.9 vs 1.8 ± 2.8 points; P = 0.001), 4 hours (4.6 ± 2.0 vs 1.4 ± 2.3 points; P dextrose recipients and 19% (3/16) of saline recipients reported ≥ 50% pain reduction at 4 hours (P dextrose on pain at the dorsal root level; waning pain control at 2 weeks suggests the need to assess the effect of serial dextrose epidural injections in a long-term study with robust outcome assessment.

  7. Experimental Analysis for Factors Affecting the Repeatability of Plastics Injection Molding Tests on the Self-developed Apparatus

    Directory of Open Access Journals (Sweden)

    Yugang Huang

    2013-06-01

    Full Text Available Normal 0 false false false IN X-NONE X-NONE MicrosoftInternetExplorer4 To improve the repeatability of the injection molding test result, the affecting factors were investigated by means of experiments. Besides the traditional processing parameter, the factors of test conditions were also considered. In order to focus on the molding process rather than the molded part, the curve measurement of the melt pressure at the entrance to the nozzle was used as the output characteristic. Experiments for polypropylene (PP showed that the injected volume was the key processing parameter. Within the test conditions, the injection number is the most important factor. According to the analysis the operating procedure was improved effectively. Normal 0 false false false IN X-NONE X-NONE MicrosoftInternetExplorer4 Doi: 10.12777/ijse.5.1.6-11 [How to cite this article: Huang, Y., Li, D., Liu, Y. (2013. Experimental Analysis for Factors Affecting the Repeatability of Plastics Injection Molding Tests on the Self-developed Apparatus. International Journal of Science and Engineering, 5(1,6-11. Doi: 10.12777/ijse.5.1.6-11]

  8. Test facility for fast gas injections into a vessel filled with water

    International Nuclear Information System (INIS)

    Wilhelm, D.; Kirstahler, M.

    1987-11-01

    The Fast Gas Injection Facility (SGI) was set up to study the hydrodynamics during the expansion of a gas bubble into a vessel filled with water. The gas stored in a pressure vessel expands against gravity through a circular duct into a large cylindrical vessel partly with water. This report covers the description of the test facility and the data acquisition. Results of the first test series are added. (orig.) [de

  9. Interim Report: 100-NR-2 Apatite Treatability Test: Low Concentration Calcium Citrate-Phosphate Solution Injection for In Situ Strontium-90 Immobilization

    Energy Technology Data Exchange (ETDEWEB)

    Williams, Mark D.; Fritz, Brad G.; Mendoza, Donaldo P.; Rockhold, Mark L.; Thorne, Paul D.; Xie, YuLong; Bjornstad, Bruce N.; Mackley, Rob D.; Newcomer, Darrell R.; Szecsody, James E.; Vermeul, Vincent R.

    2008-07-11

    Following an evaluation of potential Sr-90 treatment technologies and their applicability under 100-NR-2 hydrogeologic conditions, U.S. Department of Energy, Fluor Hanford, Inc., Pacific Northwest National Laboratory, and the Washington Department of Ecology agreed that the long-term strategy for groundwater remediation at 100-N Area will include apatite sequestration as the primary treatment, followed by a secondary treatment if necessary (most likely phytoremediation). Since then, the agencies have worked together to agree on which apatite sequestration technology has the greatest chance of reducing Sr-90 flux to the river at a reasonable cost. In July 2005, aqueous injection, (i.e., the introduction of apatite-forming chemicals into the subsurface) was endorsed as the interim remedy and selected for field testing. Studies are in progress to assess the efficacy of in situ apatite formation by aqueous solution injection to address both the vadose zone and the shallow aquifer along the 300 ft of shoreline where Sr-90 concentrations are highest. This report describes the field testing of the shallow aquifer treatment.

  10. A New Sacroiliac Joint Injection Technique and Its Short-Term Effect on Chronic Sacroiliac Region Pain.

    Science.gov (United States)

    Do, Kyung Hee; Ahn, Sang Ho; Jones, Rodney; Jang, Sung Ho; Son, Su Min; Lee, Dong Gyu; Cho, Hee Kyung; Choi, Gyu Sik; Cho, Yun-Woo

    2016-10-01

    Sacroiliac joint (SIJ) injections have been used to provide short-term relief of SIJ pain. In this study, the authors investigated a new technique using a superior approach. Twenty four patients with chronic SI joint paint were recruited. Each patient was treated with a single SIJ intra-articular injection plus a periarticular injection of local anesthetic and corticosteroid in one procedure. Technical accuracy of the intra-articular procedure was determined by having 2 independent observers review and rate the quality of arthrograms obtained. Treatment effects were evaluated using a numerical rating scale, the Oswestry disability index (ODI) and global perceived effect (GPE). Both independent observers agreed that satisfactory arthrograms were obtained in all patients. Pain scores and disability were significantly reduced at 2 weeks and 4 weeks after treatment. Nineteen patients (79%) reported satisfaction with treatment. No serious adverse effects were encountered. The superior approach consistently achieves good access to the SI joint, and achieves outcomes that are compatible with those of other techniques. The superior approach constitutes an alternative to other techniques for injections into the SI joint. © 2016 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  11. Surface self-potential patterns related to transmissive fracture trends during a water injection test

    Science.gov (United States)

    DesRoches, A. J.; Butler, K. E.; MacQuarrie, K. TB

    2018-03-01

    Variations in self-potential (SP) signals were recorded over an electrode array during a constant head injection test in a fractured bedrock aquifer. Water was injected into a 2.2 m interval isolated between two inflatable packers at 44 m depth in a vertical well. Negative SP responses were recorded on surface corresponding to the start of the injection period with strongest magnitudes recorded in electrodes nearest the well. SP response decreased in magnitude at electrodes further from the well. Deflation of the packer system resulted in a strong reversal in the SP signal. Anomalous SP patterns observed at surface at steady state were found to be aligned with dominant fracture strike orientations found within the test interval. Numerical modelling of fluid and current flow within a simplified fracture network showed that azimuthal patterns in SP are mainly controlled by transmissive fracture orientations. The strongest SP gradients occur parallel to hydraulic gradients associated with water flowing out of the transmissive fractures into the tighter matrix and other less permeable cross-cutting fractures. Sensitivity studies indicate that increasing fracture frequency near the well increases the SP magnitude and enhances the SP anomaly parallel to the transmissive set. Decreasing the length of the transmissive fractures leads to more fluid flow into the matrix and into cross-cutting fractures proximal to the well, resulting in a more circular and higher magnitude SP anomaly. Results from the field experiment and modelling provide evidence that surface-based SP monitoring during constant head injection tests has the ability to identify groundwater flow pathways within a fractured bedrock aquifer.

  12. The University of Minnesota aquifer thermal energy storage (ATES) field test facility -- system description, aquifer characterization, and results of short-term test cycles

    Energy Technology Data Exchange (ETDEWEB)

    Walton, M.; Hoyer, M.C.; Eisenreich, S.J.; Holm, N.L.; Holm, T.R.; Kanivetsky, R.; Jirsa, M.A.; Lee, H.C.; Lauer, J.L.; Miller, R.T.; Norton, J.L.; Runke, H. (Minnesota Geological Survey, St. Paul, MN (United States))

    1991-06-01

    Phase 1 of the Aquifer Thermal Energy Storage (ATES) Project at the University of Minnesota was to test the feasibility, and model, the ATES concept at temperatures above 100{degrees}C using a confined aquifer for the storage and recovery of hot water. Phase 1 included design, construction, and operation of a 5-MW thermal input/output field test facility (FTF) for four short-term ATES cycles (8 days each of heat injection, storage, and heat recover). Phase 1 was conducted from May 1980 to December 1983. This report describes the FTF, the Franconia-Ironton-Galesville (FIG) aquifer used for the test, and the four short-term ATES cycles. Heat recovery; operational experience; and thermal, chemical, hydrologic, and geologic effects are all included. The FTF consists of monitoring wells and the source and storage well doublet completed in the FIG aquifer with heat exchangers and a fixed-bed precipitator between the wells of the doublet. The FIG aquifer is highly layered and a really anisotropic. The upper Franconia and Ironton-Galesville parts of the aquifer, those parts screened, have hydraulic conductivities of {approximately}0.6 and {approximately}1.0 m/d, respectively. Primary ions in the ambient ground water are calcium and magnesium bicarbonate. Ambient temperature FIG ground water is saturated with respect to calcium/magnesium bicarbonate. Heating the ground water caused most of the dissolved calcium to precipitate out as calcium carbonate in the heat exchanger and precipitator. Silica, calcium, and magnesium were significantly higher in recovered water than in injected water, suggesting dissolution of some constituents of the aquifer during the cycles. Further work on the ground water chemistry is required to understand water-rock interactions.

  13. Experimental results of the SMART ECC injection performance with reduced scale of test facility

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Young Il; Cho, Seok; Ko, Yung Joo; Shin, Yong Cheol; Kwon, Tae Soon [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2011-05-15

    SMART pressurized water reactor type is different from the existing integral NSSS commercial pressurized water reactor system which is equipped with the main features. In addition, RCS piping is removed and the feature of the SBLOCA is a major design break accident. SWAT (SMART ECC Water Asymmetric Two-phase choking test facility) test facility is to simulate the 2 inch SBLOCA of the SMART using with reduced scale. The Test was performed to produce experimental data for the validation of the TASS/SMR-S thermal hydraulic analysis code, and to investigate the related thermal hydraulic phenomena in the down-comer region during the 2 inch SBLOCA of the safety inject line. The particular phenomena for the observation are ECC bypass and multi-dimensional flow characteristics to verify the effectiveness and performance of the safety injection system. In this paper, the corresponding steady state test conditions, including initial and boundary conditions along with major measuring parameters, and related experimental results were described

  14. Transition from depressurization to long term cooling in AP600 scaled integral test facilities

    International Nuclear Information System (INIS)

    Bessette, D.E.; Marzo, M. di

    1999-01-01

    A novel light water reactor design called the AP600 has been proposed by the Westinghouse Electric Corporation. In the evaluation of this plant's behavior during a small break loss of coolant accident (LOCA), the crucial transition to low pressure, long-term cooling is marked by the injection of the gravitationally driven flow from the in-containment refueling water storage tank (IRWST). The onset of this injection is characterized by intermittency in the IRWST flow. This happens at a time when the reactor vessel reaches its minimum inventory. Therefore, it is important to understand and scale the behavior of the integral experimental test facilities during this portion of the transient. The explanation is that the periodic liquid drains and refills of the pressurizer are the reason for the intermittent behavior. The momentum balance for the surge line yields the nondimensional parameter controlling this process. Data from one of the three experimental facilities represent the phenomena well at the prototypical scale. The impact of the intermittent IRWST injection on the safe plant operation is assessed and its implications are successfully resolved. The oscillation is found to result from, in effect, excess water in the primary system and it is not of safety significance. (orig.)

  15. Labeling of hepatic glycogen after short- and long-term stimulation of glycogen synthesis in rats injected with 3H-galactose

    International Nuclear Information System (INIS)

    Michaels, J.E.; Garfield, S.A.; Hung, J.T.; Cardell, R.R. Jr.

    1990-01-01

    The effects of short- and long-term stimulation of glycogen synthesis elicited by dexamethasone were studied by light (LM) and electron (EM) microscopic radioautography (RAG) and biochemical analysis. Adrenalectomized rats were fasted overnight and pretreated for short- (3 hr) or long-term (14 hr) periods with dexamethasone prior to intravenous injection of tracer doses of 3H-galactose. Analysis of LM-RAGs from short-term rats revealed that about equal percentages (44%) of hepatocytes became heavily or lightly labeled 1 hr after labeling. The percentage of heavily labeled cells increased slightly 6 hr after labeling, and unlabeled glycogen became apparent in some hepatocytes. The percentage of heavily labeled cells had decreased somewhat 12 hr after labeling, and more unlabeled glycogen was evident. In the long-term rats 1 hr after labeling, a higher percentage of heavily labeled cells (76%) was observed compared to short-term rats, and most glycogen was labeled. In spite of the high amount of labeling seen initially, the percentage of heavily labeled hepatocytes had decreased considerably to 55% by 12 hr after injection; and sparsely labeled and unlabeled glycogen was prevalent. The EM-RAGs of both short- and long-term rats were similar. Silver grains were associated with glycogen patches 1 hr after labeling; 12 hr after labeling, the glycogen patches had enlarged; and label, where present, was dispersed over the enlarged glycogen clumps. Analysis of DPM/mg tissue corroborated the observed decrease in label 12 hr after administration in the long-term animals. The loss of label observed 12 hr after injection in the long-term pretreated rats suggests that turnover of glycogen occurred during this interval despite the net accumulation of glycogen that was visible morphologically and evident from biochemical measurement

  16. RELAP5 analysis of PACTEL injection tests

    International Nuclear Information System (INIS)

    Kimber, G.R.; Lillington, J.N.

    2000-01-01

    A characteristic feature of advanced reactor designs is their reliance on passive safety systems. It is important to assess both the operation of such systems and the ability of systems codes, such as RELAP5, to model them. In Finland VTT Energy, together with Lappeenranta University of Technology, is using the PACTEL facility for the investigation of passive core cooling systems. In particular, a core make-up tank (CMT) has been installed in the rig to operate in a similar manner to those in many Advanced PWR designs. Three small break tests, GDE-24, GDE-34 and GDE-43 in the PACTEL facility were chosen for modelling with RELAP5. The objective of GDE-24 was to investigate CMT behaviour and in particular the effects of condensation in the CMT. The second test, GDE-34, was similar except that it had a smaller CMT and at the start of the test the water in the CMT and connecting pipework was at an elevated temperature. Test GDE-43 focused on conditions when the driving force for flow through the passive system injection system (PSIS) slowly disappears. Analysis of all tests reported here was carried out with RELAP5/MOD 3.2.1.2. The paper summarises the conclusions of all the tests. A critical part of the study revolved around modelling of the CMT. A model was developed to allow its detailed behaviour to be investigated more easily. This enabled recommendations for improving the condensation modelling in RELAP5 to be made. Apart from the wall condensation modelling issue, the implication of the work is that RELAP5/MOD 3.2.1.2 (a comparatively recent version of the code) is broadly adequate for these applications. (author)

  17. people who inject drugs, HIV risk, and HIV testing uptake in sub-Saharan Africa.

    Science.gov (United States)

    Asher, Alice K; Hahn, Judith A; Couture, Marie-Claude; Maher, Kelsey; Page, Kimberly

    2013-01-01

    Dramatic rises in injection drug use (IDU) in sub-Saharan Africa account for increasingly more infections in a region already overwhelmed by the HIV epidemic. There is no known estimate of the number of people who inject drugs (PWID) in the region, or the associated HIV prevalence in PWID. We reviewed literature with the goal of describing high-risk practices and exposures in PWID in sub-Saharan Africa, as well as current HIV prevention activities aimed at drug use. The literature search looked for articles related to HIV risk, injection drug users, stigma, and HIV testing in sub-Saharan Africa. This review found evidence demonstrating high rates of HIV in IDU populations in sub-Saharan Africa, high-risk behaviors of the populations, lack of knowledge regarding HIV, and low HIV testing uptake. There is an urgent need for action to address IDU in order to maintain recent decreases in the spread of HIV in sub-Saharan Africa. Copyright © 2013 Association of Nurses in AIDS Care. Published by Elsevier Inc. All rights reserved.

  18. Sorbent Injection for Small ESP Mercury Control in Low Sulfur Eastern Bituminous Coal Flue Gas

    Energy Technology Data Exchange (ETDEWEB)

    Carl Richardson; Katherine Dombrowski; Douglas Orr

    2006-12-31

    This project Final Report is submitted to the U.S. Department of Energy (DOE) as part of Cooperative Agreement DE-FC26-03NT41987, 'Sorbent Injection for Small ESP Mercury Control in Low Sulfur Eastern Bituminous Coal Flue Gas.' Sorbent injection technology is targeted as the primary mercury control process on plants burning low/medium sulfur bituminous coals equipped with ESP and ESP/FGD systems. About 70% of the ESPs used in the utility industry have SCAs less than 300 ft2/1000 acfm. Prior to this test program, previous sorbent injection tests had focused on large-SCA ESPs. This DOE-NETL program was designed to generate data to evaluate the performance and economic feasibility of sorbent injection for mercury control at power plants that fire bituminous coal and are configured with small-sized electrostatic precipitators and/or an ESP-flue gas desulfurization (FGD) configuration. EPRI and Southern Company were co-funders for the test program. Southern Company and Reliant Energy provided host sites for testing and technical input to the project. URS Group was the prime contractor to NETL. ADA-ES and Apogee Scientific Inc. were sub-contractors to URS and was responsible for all aspects of the sorbent injection systems design, installation and operation at the different host sites. Full-scale sorbent injection for mercury control was evaluated at three sites: Georgia Power's Plant Yates Units 1 and 2 [Georgia Power is a subsidiary of the Southern Company] and Reliant Energy's Shawville Unit 3. Georgia Power's Plant Yates Unit 1 has an existing small-SCA cold-side ESP followed by a Chiyoda CT-121 wet scrubber. Yates Unit 2 is also equipped with a small-SCA ESP and a dual flue gas conditioning system. Unit 2 has no SO2 control system. Shawville Unit 3 is equipped with two small-SCA cold-side ESPs operated in series. All ESP systems tested in this program had SCAs less than 250 ft2/1000 acfm. Short-term parametric tests were conducted on Yates

  19. Integrated dry NO{sub x}/SO{sub 2} emissions control system sodium-based dry sorbent injection test report. Test period: August 4, 1993--July 29, 1995

    Energy Technology Data Exchange (ETDEWEB)

    Smith, R.A.; Shimoto, G.H.; Muzio, L.J. [Fossil Energy Research Corp., Laguna Hills, CA (United States); Hunt, T. [Public Service Co. of Colorado, Denver, CO (United States)

    1997-04-01

    The project goal is to demonstrate up to 70% reductions in NOx and SO{sub 2} emissions through the integration of: (1) down-fired low-NOx burners with overfire air; (2) Selective Non-Catalytic Reduction (SNCR) for additional NOx removal; and (3) dry sorbent injection and duct humidification for SO{sub 2} removal. This report documents the sixth phase of the test program, where the performance of dry sorbent injection with sodium compounds was evaluated as a SO{sub 2} removal technique. Dry sorbent injection was performed in-duct downstream of the air heater (ahead of the fabric filter), as well as at a higher temperature location between the economizer and air heater. Two sodium compounds were evaluated during this phase of testing: sodium sesquicarbonate and sodium bicarbonate. In-duct sodium injection with low levels of humidification was also investigated. This sixth test phase was primarily focused on a parametric investigation of sorbent type and feed rate, although boiler load and sorbent preparation parameters were also varied.

  20. Atomization and spray characteristics of bioethanol and bioethanol blended gasoline fuel injected through a direct injection gasoline injector

    International Nuclear Information System (INIS)

    Park, Su Han; Kim, Hyung Jun; Suh, Hyun Kyu; Lee, Chang Sik

    2009-01-01

    The focus of this study was to investigate the spray characteristics and atomization performance of gasoline fuel (G100), bioethanol fuel (E100), and bioethanol blended gasoline fuel (E85) in a direct injection gasoline injector in a gasoline engine. The overall spray and atomization characteristics such as an axial spray tip penetration, spray width, and overall SMD were measured experimentally and predicted by using KIVA-3V code. The development process and the appearance timing of the vortices in the test fuels were very similar. In addition, the numerical results accurately described the experimentally observed spray development pattern and shape, the beginning position of the vortex, and the spray breakup on the spray surface. Moreover, the increased injection pressure induced the occurrence of a clear circular shape in the downstream spray and a uniform mixture between the injected spray droplets and ambient air. The axial spray tip penetrations of the test fuels were similar, while the spray width and spray cone angle of E100 were slightly larger than the other fuels. In terms of atomization performance, the E100 fuel among the tested fuels had the largest droplet size because E100 has a high kinematic viscosity and surface tension.

  1. Simulation of long-term behavior in HLW near-field by centrifugal model test. Part 4. Model test of coupled THM processes in isotropic stress conditions using heatable overpack

    International Nuclear Information System (INIS)

    Nishimoto, Soshi; Okada, Tetsuji; Sawada, Masataka

    2014-01-01

    We demonstrated the equivalent long-term behavior in the near-field of a geological repository for high level radioactive waste disposal, using the centrifugal near-field model test under the coupled thermo-hydraulic-mechanical condition. The model consisted of a sedimentary bedrock, buffer, and heating type model overpack, and was enclosed within a pressure vessel. Tests were conducted with a centrifugal force field of 30 G under isotropic stress-constrain conditions with confining pressures and injection of pore water. The temperature condition of the overpack was constantly 95°C. As the result, the values showed similar behaviors to that of the normal temperature tests partially. However, the different behaviors were measured such as the displacement of overpack change from the settlement to the heave, the extreme drop in the soil pressure of the buffer and the strain of side wall of bedrock change from the tension to the compression after injecting pore water of hundreds hours. In addition, the flow rate of the injection pore water suddenly changed after hundreds of hours. Furthermore, the density of the buffer was lower than that of the normal temperature tests by X-ray CT imaging in the post-tests. We infer that the high temperature overpack influenced the stiffness and the pore water distribution of the buffer, and the density and the soil pressure of the buffer decreased. As a result of the change of stiffness in the disposal hole (buffer), the tendency to the strain of the surrounding bedrock and the displacement of the overpack changed. (author)

  2. Sex work involvement among women with long-term opioid injection drug dependence who enter opioid agonist treatment.

    Science.gov (United States)

    Marchand, Kirsten; Oviedo-Joekes, Eugenia; Guh, Daphne; Marsh, David C; Brissette, Suzanne; Schechter, Martin T

    2012-01-25

    Substitution with opioid-agonists (e.g., methadone) has shown to be an effective treatment for chronic long-term opioid dependency. Survival sex work, very common among injection drug users, has been associated with poor Opioid Agonist Treatment (OAT) engagement, retention and response. Therefore, this study was undertaken to determine factors associated with engaging in sex work among long-term opioid dependent women receiving OAT. Data from a randomized controlled trial, the North American Opiate Medication Initiative (NAOMI), conducted in Vancouver and Montreal (Canada) between 2005-2008, was analyzed. The NAOMI study compared the effectiveness of oral methadone to injectable diacetylmorphine or injectable hydromorphone, the last two on a double blind basis, over 12 months. A research team, independent of the clinic services, obtained outcome evaluations at baseline and follow-up (3, 6, 9, 12, 18 and 24 months). A total 53.6% of women reported engaging in sex work in at least one of the research visits. At treatment initiation, women who were younger and had fewer years of education were more likely to be engaged in sex work. The multivariate logistic generalized estimating equation regression analysis determined that psychological symptoms, and high illicit heroin and cocaine use correlated with women's involvement in sex work during the study period. After entering OAT, women using injection drugs and engaging in sex work represent a particularly vulnerable group showing poorer psychological health and a higher use of heroin and cocaine compared to women not engaging in sex work. These factors must be taken into consideration in the planning and provision of OAT in order to improve treatment outcomes. NCT00175357.

  3. Sex work involvement among women with long-term opioid injection drug dependence who enter opioid agonist treatment

    Directory of Open Access Journals (Sweden)

    Marchand Kirsten

    2012-01-01

    Full Text Available Abstract Background Substitution with opioid-agonists (e.g., methadone has shown to be an effective treatment for chronic long-term opioid dependency. Survival sex work, very common among injection drug users, has been associated with poor Opioid Agonist Treatment (OAT engagement, retention and response. Therefore, this study was undertaken to determine factors associated with engaging in sex work among long-term opioid dependent women receiving OAT. Methods Data from a randomized controlled trial, the North American Opiate Medication Initiative (NAOMI, conducted in Vancouver and Montreal (Canada between 2005-2008, was analyzed. The NAOMI study compared the effectiveness of oral methadone to injectable diacetylmorphine or injectable hydromorphone, the last two on a double blind basis, over 12 months. A research team, independent of the clinic services, obtained outcome evaluations at baseline and follow-up (3, 6, 9, 12, 18 and 24 months. Results A total 53.6% of women reported engaging in sex work in at least one of the research visits. At treatment initiation, women who were younger and had fewer years of education were more likely to be engaged in sex work. The multivariate logistic generalized estimating equation regression analysis determined that psychological symptoms, and high illicit heroin and cocaine use correlated with women's involvement in sex work during the study period. Conclusions After entering OAT, women using injection drugs and engaging in sex work represent a particularly vulnerable group showing poorer psychological health and a higher use of heroin and cocaine compared to women not engaging in sex work. These factors must be taken into consideration in the planning and provision of OAT in order to improve treatment outcomes. Trial Registration NCT00175357.

  4. Efficacy and safety of corticosteroid injections and other injections for management of tendinopathy: a systematic review of randomised controlled trials.

    Science.gov (United States)

    Coombes, Brooke K; Bisset, Leanne; Vicenzino, Bill

    2010-11-20

    Few evidence-based treatment guidelines for tendinopathy exist. We undertook a systematic review of randomised trials to establish clinical efficacy and risk of adverse events for treatment by injection. We searched eight databases without language, publication, or date restrictions. We included randomised trials assessing efficacy of one or more peritendinous injections with placebo or non-surgical interventions for tendinopathy, scoring more than 50% on the modified physiotherapy evidence database scale. We undertook meta-analyses with a random-effects model, and estimated relative risk and standardised mean differences (SMDs). The primary outcome of clinical efficacy was protocol-defined pain score in the short term (4 weeks, range 0-12), intermediate term (26 weeks, 13-26), or long term (52 weeks, ≥52). Adverse events were also reported. 3824 trials were identified and 41 met inclusion criteria, providing data for 2672 participants. We showed consistent findings between many high-quality randomised controlled trials that corticosteroid injections reduced pain in the short term compared with other interventions, but this effect was reversed at intermediate and long terms. For example, in pooled analysis of treatment for lateral epicondylalgia, corticosteroid injection had a large effect (defined as SMD>0·8) on reduction of pain compared with no intervention in the short term (SMD 1·44, 95% CI 1·17-1·71, ptendon rupture). By comparison with placebo, reductions in pain were reported after injections of sodium hyaluronate (short [3·91, 3·54-4·28, peffective than was eccentric exercise. Despite the effectiveness of corticosteroid injections in the short term, non-corticosteroid injections might be of benefit for long-term treatment of lateral epicondylalgia. However, response to injection should not be generalised because of variation in effect between sites of tendinopathy. None. Copyright © 2010 Elsevier Ltd. All rights reserved.

  5. Sequential injection lab-on-valve: the third generation of flow injection analysis

    DEFF Research Database (Denmark)

    Wang, Jianhua; Hansen, Elo Harald

    2003-01-01

    Termed the third generation of flow injection analysis, sequential injection (SI)-lab-on-valve (LOV) has specific advantages and allows novel, unique applications - not least as a versatile front end to a variety of detection techniques. This review presents snd discusses progress to date of the ...

  6. Interpretation and modeling of a subsurface injection test, 200 East Area, Hanford, Washington

    International Nuclear Information System (INIS)

    Smoot, J.L.; Lu, A.H.

    1994-11-01

    A tracer experiment was conducted in 1980 and 1981 in the unsaturated zone in the southeast portion of the Hanford 200 East Area near the Plutonium-Uranium Extraction (PUREX) facility. The field design consisted of a central injection well with 32 monitoring wells within an 8-m radius. Water containing radioactive and other tracers was injected weekly during the experiment. The unique features of the experiment were the documented control of the inputs, the experiment's three-dimensional nature, the in-situ measurement of radioactive tracers, and the use of multiple injections. The spacing of the test wells provided reasonable lag distribution for spatial correlation analysis. Preliminary analyses indicated spatial correlation on the order of 400 to 500 cm in the vertical direction. Previous researchers found that two-dimensional axisymmetric modeling of moisture content generally underpredicts lateral spreading and overpredicts vertical movement of the injected water. Incorporation of anisotropic hydraulic properties resulted in the best model predictions. Three-dimensional modeling incorporated the geologic heterogeneity of discontinuous layers and lenses of sediment apparent in the site geology. Model results were compared statistically with measured experimental data and indicate reasonably good agreement with vertical and lateral field moisture distributions

  7. Case study on ground surface deformation induced by CO2 injection into coal seam

    International Nuclear Information System (INIS)

    Li Hong; Tang Chun'an

    2010-01-01

    To monitor a geomechanical response of injecting CO 2 into relatively shallow coal seams, tiltmeters were set as an array to cover the ground surface area surrounding the injection well, and to measure the ground deformation during a well fracturing stimulation and a short-term CO 2 injection test. In this paper, an attempt to establish a quantitative relationship between the in-situ coal swelling and the corresponding ground deformation was made by means of numerical simulation study. (authors)

  8. Percutaneous ethanol injection therapy (PEIT) for small hepatocellular carcinomas (HCCs) : prognostic factors affecting short-term follow-up results

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ah Young; Han, Joon Koo; Kim, Tae Kyoung; Yun, Eun Joo; Lee, Ki Yeol; Choi, Byung Ihn [Seoul National Univ. (Korea, Republic of). Coll. of Medicine

    1998-06-01

    The purpose of this study is to analyze the effect of various parameters used in PEIT on the short-term results of this procedure for the treatment of small HCC. Among 76 lesions in 63 patients with HCCs, 66 were diagnosed by tissue biopsy (n=30) or according to clinical features, tumor marker, and the results of angiography and other diagnostic imagings (n=36). These patients underwent PEIT between November 1993 and October 1996; the indications for PEIT were nodular lesions less than 3 cm in size, less than three in number, and unsuitable for surgical resection or transcatheter arterial chemoembolization therapy. The effect of PEIT was evaluated by two phase spiral CT one month later (64 lesions) or by serial ultrasound for 6 months. We analyzed and graded the short-term effect of PEIT on HCCs as complete remission (CR), partial remission (PR) or no change/aggravation (NC/AG). We also evaluated the correlation between the short-term results of PEIT and variable parameters such as size of the lesion, frequency of PEI per session, child classification of the patient, the ratio of amount of injected ethanol per volume of the lesion, and {alpha}-fetoprotein level before the procedure. The therapeutic effect of PEIT was CR in 45 lesions (59.2%), PR in 18 (23.7%) and NC/AG in 13 (17.1%). The size of the tumor, child-pugh class, number of injections per session and ratio of injected volume of ethanol to tumor volume were factors affecting the therapeutic result (p < 0.05). Sufficient knowledge of prognostic factors affecting the short-term results of PEIT might help improve the effects of therapy in patients its small HCCs. (author). 19 refs., 6 figs.

  9. The research of new type stratified water injection process intelligent measurement technology

    Science.gov (United States)

    Zhao, Xin

    2017-10-01

    To meet the needs of injection and development of Daqing Oilfield, the injection of oil from the early stage of general water injection to the subdivision of water is the purpose of improving the utilization degree and the qualified rate of water injection, improving the performance of water injection column and the matching process. Sets of suitable for high water content of the effective water injection technology supporting technology. New layered water injection technology intelligent measurement technology will be more information testing and flow control combined into a unified whole, long-term automatic monitoring of the work of the various sections, in the custom The process has the characteristics of "multi-layer synchronous measurement, continuous monitoring of process parameters, centralized admission data", which can meet the requirement of subdivision water injection, but also realize the automatic synchronization measurement of each interval, greatly improve the efficiency of tiered injection wells to provide a new means for the remaining oil potential.

  10. Relevant climate response tests for stratospheric aerosol injection: A combined ethical and scientific analysis

    Science.gov (United States)

    Lenferna, Georges Alexandre; Russotto, Rick D.; Tan, Amanda; Gardiner, Stephen M.; Ackerman, Thomas P.

    2017-06-01

    In this paper, we focus on stratospheric sulfate injection as a geoengineering scheme, and provide a combined scientific and ethical analysis of climate response tests, which are a subset of outdoor tests that would seek to impose detectable and attributable changes to climate variables on global or regional scales. We assess the current state of scientific understanding on the plausibility and scalability of climate response tests. Then, we delineate a minimal baseline against which to consider whether certain climate response tests would be relevant for a deployment scenario. Our analysis shows that some climate response tests, such as those attempting to detect changes in regional climate impacts, may not be deployable in time periods relevant to realistic geoengineering scenarios. This might pose significant challenges for justifying stratospheric sulfate aerosol injection deployment overall. We then survey some of the major ethical challenges that proposed climate response tests face. We consider what levels of confidence would be required to ethically justify approving a proposed test; whether the consequences of tests are subject to similar questions of justice, compensation, and informed consent as full-scale deployment; and whether questions of intent and hubris are morally relevant for climate response tests. We suggest further research into laboratory-based work and modeling may help to narrow the scientific uncertainties related to climate response tests, and help inform future ethical debate. However, even if such work is pursued, the ethical issues raised by proposed climate response tests are significant and manifold.

  11. English-Japanese terms in nondestructive testing specifications

    International Nuclear Information System (INIS)

    1991-01-01

    For technical development, it is the prerequisite to clarify the terms to be used in various fields and their definition, therefore, in various foreign countries, there are some standards on terms in respective fields, and also as international standards, ISO/TC 135 (Non-destructive testing) organized the SC on terms from the beginning of foundation. In JIS, there is the column for corresponding English (for reference), but there is the problem of English and American English. The English used in ISO, BS or EN and ASTM standards in relation to nondestructive testing were collected in every technical field and put in order, and the corresponding English terms were selected. Moreover at this opportunity, the terms having the definition in these international, national and semi-national standards were classified into eight fields, that is, common (approval, quality assurance, defects and others), radiography, ultrasonic flaw detection, acoustic emission, eddy current flaw detection, magnetic flaw detection, liquid penetrant testing and leak test, and the Japanese translation was stipulated. The draft of this standard was approved by the standardization committee on January 17, 1991. (K.I.)

  12. Long-term follow-up of ultrasound-guided botulinum toxin-A injections for sialorrhea in neurological dysphagia.

    Science.gov (United States)

    Barbero, Pierangelo; Busso, Marco; Tinivella, Marco; Artusi, Carlo Alberto; De Mercanti, Stefania; Cucci, Angele; Veltri, Andrea; Avagnina, Paolo; Calvo, Andrea; Chio', Adriano; Durelli, Luca; Clerico, Marinella

    2015-12-01

    Literature provides reports only of a limited follow-up single injection of botulinum toxin-A (BoNT-A) in patients with sialorrhea. The aim of our study is to evaluate the long-lasting efficacy and safety of ultrasound-guided BoNT-A injections for severe sialorrhea secondary to neurological dysphagia. We enrolled 38 severe adult sialorrhea patients referred consecutively to the neurology unit and performed bilateral parotid and submandibular gland BoNT-A injections under ultrasound guidance. The outcomes of the study were reduction of sialorrhea, duration of therapeutic effect, and subjective patient- and caregiver-reported satisfaction. A total of 113 BoNT-A administrations were given during the study period with a mean duration of follow-up of 20.2 ± 4.4 months. We observed a significant decrease from baseline in mean number of daily aspirations and a significant improvement in patient- and caregiver-reported outcomes following ultrasound-guided BoNT-A injections (p < 0.001 vs baseline for all comparisons) and the mean duration of the efficacy was 5.6 ± 1 months. No major treatment-related adverse events occurred and a low incidence of minor adverse events was reported. This study confirms the long-lasting efficacy and safety of ultrasound-guided BoNT-A injections for sialorrhea, regardless of the causative neurological disorder. These results should encourage the use of BoNT-A in the treatment of severe sialorrhea and highlight the role of ultrasound guidance to obtain optimal results in terms of safety and reproducible outcomes.

  13. Long-term Results of Intravitreal Anti-VEGF Injections in Wet AMD: A Meta-Analysis.

    Science.gov (United States)

    Gerding, H

    2016-04-01

    Although intravitreal anti-VEGF medications are widely used in age-related macular degeneration, no systematic data analysis is available on the long-term prognosis of this relatively new therapeutic approach. A meta-analysis was performed on available Medline literature. 13 relevant clinical studies (14 case series) could be identified, covering 10 247 treated eyes. The majority of available reports originate from single centre retrospective real-life environments. The mean improvement in average visual gain was 0.9 ± 0.5 (mean ± 1 standard deviation, median; 0.8 lines) at year 1, 1.2 ± 1.1 (median: 1.1) letters at year 2, 0.7 ± 1.0 (median: 0.7) letters at year 3, and 0.2 ± 0.8 (median: 0.5), 0.4 ± 0.4 (median: 0.5) at years 4 and 5. The drop-out rates in these studies was relatively high. At the end of year 3, the average percentage of observed eyes was 44.3 ± 18.4 % (mean ± 1 standard deviation), at the end of year 4 23.5 ± 23.9 % and after years 6 and 7 below 10 % (8.2 and 7.9 %). The mean treatment frequency of injections in all available studies was highest in year 1 (6.4 ± 1.2, 6.1 - mean ± SD; median), followed by relatively consistent mean values of 4.1 and 5.1 (year (Y)2: 4.4, Y3: 4.3, Y4: 4.7, Y5: 4.1, Y6: 5.1, Y7: 4.7) injections per year. The results of this meta-analysis clearly indicate that intravitreal anti-VEGF injection therapy is capable of maintaining visual acuity on a long-term basis of at least 4-5 years. Georg Thieme Verlag KG Stuttgart · New York.

  14. Evaluation the short term effects on serum creatinine concentration in patients with normal renal function, mild and moderate renal insufficiency after intravenous injection of gadopentetate dimeglumine

    International Nuclear Information System (INIS)

    Luo Jian; Liu Jing; Wang Xiaoying; Yang Xuedong; Jiang Xuexiang

    2010-01-01

    Objective: To explore the effects of gadopentetate dimeglumine injection on renal function. Methods: The study included 623 consecutive patients. Their serum creatinine concentrations before and within 3 days after injection of gadopentetate dimeglumine were analyzed. Their eGFR (estimated glomerular filtration rate) were calculated. Patients were divided into two groups according to their injection dose: group received single dose and group received double dose. Patients in each group were subdivided into three subgroups according to their eGFR: subgroup of normal renal function, subgroup of mild renal insufficiency and subgroup of moderate renal insufficiency. Paried sample t test and group design paired sample Rank Sum test were used for statistical analysis. Results: There was no adverse reaction or occurrence of acute renal insufficiency. The mean level of serum creatinine dropped from (74.0± 17.2) μmol/L to (71.5±19.0) μmol/L (t=5.39, P 0.05) in subgroup of mild renal insufficiency under group received double dose and increased from (118.3±15.3) μmol/L to (135.7±8.5) μmol/L (t=2.02, P<0.05) in subgroup of moderate renal insufficiency under group received double dose, the mean level of serum creatinine dropped in all other subgroups. Conclusions: Single dose gadopentetate dimeglumine is safe for patients with normal renal function and mild, moderate renal insufficiency in short term, but patients with abnormal renal function should be followed up after double dose injection. (authors)

  15. MK-801 and memantine act differently on short-term memory tested with different time-intervals in the Morris water maze test.

    Science.gov (United States)

    Duda, Weronika; Wesierska, Malgorzata; Ostaszewski, Pawel; Vales, Karel; Nekovarova, Tereza; Stuchlik, Ales

    2016-09-15

    N-methyl-d-aspartate receptors (NMDARs) play a crucial role in spatial memory formation. In neuropharmacological studies their functioning strongly depends on testing conditions and the dosage of NMDAR antagonists. The aim of this study was to assess the immediate effects of NMDAR block by (+)MK-801 or memantine on short-term allothetic memory. Memory was tested in a working memory version of the Morris water maze test. In our version of the test, rats underwent one day of training with 8 trials, and then three experimental days when rats were injected intraperitoneally with low- 5 (MeL), high - 20 (MeH) mg/kg memantine, 0.1mg/kg MK-801 or 1ml/kg saline (SAL) 30min before testing, for three consecutive days. On each experimental day there was just one acquisition and one test trial, with an inter-trial interval of 5 or 15min. During training the hidden platform was relocated after each trial and during the experiment after each day. The follow-up effect was assessed on day 9. Intact rats improved their spatial memory across the one training day. With a 5min interval MeH rats had longer latency then all rats during retrieval. With a 15min interval the MeH rats presented worse working memory measured as retrieval minus acquisition trial for path than SAL and MeL and for latency than MeL rats. MK-801 rats had longer latency than SAL during retrieval. Thus, the high dose of memantine, contrary to low dose of MK-801 disrupts short-term memory independent on the time interval between acquisition and retrieval. This shows that short-term memory tested in a working memory version of water maze is sensitive to several parameters: i.e., NMDA receptor antagonist type, dosage and the time interval between learning and testing. Copyright © 2016. Published by Elsevier B.V.

  16. Heavy oil reservoir evaluation : performing an injection test using DST tools in the marine region of Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Loaiza, J.; Ruiz, P. [Halliburton, Mexico City (Mexico); Barrera, D.; Gutierrez, F. [Pemex, Mexico City (Mexico)

    2010-07-01

    This paper described an injection test conducted to evaluate heavy oil reserves in an offshore area of Mexico. The drill-stem testing (DST) evaluation used a fluid injection technique in order to eliminate the need for artificial lift and coiled tubing. A pressure transient analysis method was used to determine the static pressure of the reservoir, effective hydrocarbon permeability, and formation damage. Boundary effects were also characterized. The total volume of the fluid injection was determined by analyzing various reservoir parameters. The timing of the shut-in procedure was determined by characterizing rock characteristics and fluids within the reservoir. The mobility and diffusivity relationships between the zones with the injection fluids and reservoir fluids were used to defined sweep fluids. A productivity analysis was used to predict various production scenarios. DST tools were then used to conduct a pressure-production assessment. Case histories were used to demonstrate the method. The studies showed that the method provides a cost-effective means of providing high quality data for productivity analyses. 4 refs., 2 tabs., 15 figs.

  17. Single-dose Intramuscular-injection Toxicology Test of Water-soluble Carthami-flos and Cervi cornu parvum Pharmacopuncture in a Rat Model

    Directory of Open Access Journals (Sweden)

    Sunju Park

    2015-09-01

    Full Text Available Objectives: The aim of the study is to investigate both the single-dose intramuscular injection toxicity and the approximate lethal dose of water-soluble Carthami-flos and Cervi cornu parvum pharmacopuncture (WCFC in male and female Sprague-Dawley (SD rats. Methods: The study was conducted at Biotoxtech Co. according to the Good Laboratory Practice (GLP regulation and the toxicity test guidelines of the Ministry of Food and Drug Safety (MFDS after approval of the Institutional Animal Care and Use Committee. Dosages for the control, high dose, middle dose and low dose groups were 0.5 mL/animal of saline and 0.5, 0.25 and 0.125 mL/animal of WCFC, respectively. WCFC was injected into the muscle of the left femoral region by using a disposable syringe (1 mL, 26 gauge. The general symptoms and mortality were observed 30 minutes, 1, 2, 4, and 6 hours after the first injection and then daily for 14 days after the injection. The body weights of the SD rats were measured on the day of the injection (before injection and on the third, seventh, and fourteenth days after the injection. Serum biochemical and hematologic tests, necropsy examinations, and histopathologic examinations at the injection site were performed after the observation period. Results: No deaths, abnormal clinical symptoms, or significant weight changes were observed in either male or female SD rats in the control or the test (0.125, 0.25, and 0.5 mL/animal groups during the observation period. No significant differences in hematology and serum biochemistry and no macroscopic abnormalities at necropsy were found. No abnormal reactions at injection sites were noted on the topical tolerance tests. Conclusion: The results of this single-dose toxicity study show that WCFC is safe, its lethal doses in male and female SD rats being estimated to be higher than 0.5 mL/animal.

  18. UPTF-TRAM test A3. Turn-over of the hot-leg injected ECC in the steam generator direction

    International Nuclear Information System (INIS)

    Tenckhoff; Brand, B.; Weiss, P.

    1993-06-01

    The UPTF TRAM test A3 was a separate effects test to investigate the interaction between the hot leg-injected ECC and the single-phase or two-phase natural circulation in the hot leg in the case of an SBLOCA in a PWR. The experimental investigation of 7 runs was mainly concentrated on the following phenomena: - Transport of hot leg injected ECC water to the upper plenum or in the direction of steam generator, depending on the loop mass flow, -Utilization of the condensation potential of ECC water, - Mixing of the saturated water with the ECC water, - Effect of hot leg injection on the flow phenomena in the hot leg, - Effect of pressure (3 and 15 bar) on the scaling and hence the verification of the scaling concept applied. A preliminary evaluation of the test is presented in the Quick Look Report. (orig.) [de

  19. Antigen injection (image)

    Science.gov (United States)

    Leprosy is caused by the organism Mycobacterium leprae . The leprosy test involves injection of an antigen just under ... if your body has a current or recent leprosy infection. The injection site is labeled and examined ...

  20. Spray-controlled combustionprocess with piezo injection; Strahlgefuehrtes Brennverfahren mit Piezo-Benzineinspritzung

    Energy Technology Data Exchange (ETDEWEB)

    Schaupp, U.; Altenschmidt, F.; Bertsch, D.; Laudenbach, N. [DaimlerChrysler AG, Stuttgart (Germany)

    2007-07-01

    The novel 2nd generation injection system of Mercedes-Benz have resulted in reduced fuel consumption and lower emissions while improving the engine performance. The piezo technology is a great technical advance. The characteristic field range in which stratified charge operation is possible has been extended since the first generation of injection systems. Lower fuel consumption is achieved not only in normal traffic but also when cruising on motorways at constant speed. The advantages are noticeable not only in the test cycle but also in real operation. The piezo injection valve was not available on the market and had to be constructed, including the 200 bar high-pressure fuel injection system. The stability of the injection system and the good mixing characteristics resulted in an optimally combustible mixture at the spark plug. Apart from stability in stratified charge operation, the possibility of multiple injection also has further advantages and potentials in terms of consumption and emissions. (orig.)

  1. The Development of Computer Code for Safety Injection Tank (SIT) with Fluidic Device(FD) Blowdown Test

    International Nuclear Information System (INIS)

    Lee, Joo Hee; Kim, Tae Han; Choi, Hae Yun; Lee, Kwang Won; Chung, Chang Kyu

    2007-01-01

    Safety Injection Tanks (SITs) with the Fluidic Device (FD) of APR1400 provides a means of rapid reflooding of the core following a large break Loss Of Coolant Accident (LOCA), and keeping it covered until flow from the Safety Injection Pump (SIP) becomes available. A passive FD can provide two operation stages of a safety water injection into the RCS and allow more effective use of borated water in case of LOCA. Once a large break LOCA occurs, the system will deliver a high flow rate of cooling water for a certain period of time, and thereafter, the flow rate is reduced to a lower flow rate. The conventional computer code 'TURTLE' used to simulate the blowdown of OPR1000 SIT can not be directly applied to simulate a blowdown process of the SIT with FD. A new computer code is needed to be developed for the blowdown test evaluation of the APR1400 SIT with FD. Korea Power Engineering Company (KOPEC) has developed a new computer code to analyze the characteristics of the SIT with FD and validated the code through the comparison of the calculation results with the test results obtained by Ulchin 5 and 6 units pre-operational test and VAlve Performance Evaluation Rig (VAPER) tests performed by The Korea Atomic Energy Research Institute (KAERI)

  2. In Situ Redox Manipulation Field Injection Test Report - Hanford 100-H Area

    International Nuclear Information System (INIS)

    Fruchter, J.S.; Amonette, J.E.; Cole, C.R.

    1996-11-01

    This report presents results of an In Situ Redox Manipulation (ISRM) Field Injection Withdrawal Test performed at the 100-H Area of the US. Department of Energy's (DOE's) Hanford Site in Washington State in Fiscal Year 1996 by researchers at Pacific Northwest National Laboratory (PNNL). The test is part of the overall ISRM project, the purpose of which is to determine the potential for remediating contaminated groundwater with a technology based on in situ manipulation of subsurface reduction-oxidation (redox) conditions. The ISRM technology would be used to treat subsurface contaminants in groundwater zones at DOE sites

  3. Microbiological analyses of samples from the H-Area injection well test site

    International Nuclear Information System (INIS)

    Wilde, E.W.; Franck, M.M.

    1997-01-01

    Microbial populations in well water from monitoring wells at the test site were one to three orders of magnitude higher than well water from the Cretaceous aquifer (used as dilution water for the tests) or from a control well adjacent to the test site facility. Coupons samples placed in monitoring and control wells demonstrated progressive adhesion by microbes to materials used in well construction. Samples of material scraped from test well components during abandonment of the test site project revealed the presence of a variety of attached microbes including iron bacteria. Although the injection wells at the actual remediation facility for the F- and H-Area seepage basins remediation project are expected to be subjected to somewhat different conditions (e.g. considerably lower iron concentrations) than was the case at the test site, the potential for microbiologically mediated clogging and fouling within the process should be considered. A sampling program that includes microbiological testing is highly recommended

  4. Long-term functional improvements in the 2-year treatment of schizophrenia outpatients with olanzapine long-acting injection

    Directory of Open Access Journals (Sweden)

    Ascher-Svanum H

    2014-06-01

    Full Text Available Haya Ascher-Svanum,1 Diego Novick,2,3 Josep Maria Haro,4 Jordan Bertsch,4 David McDonnell,1 Holland Detke11Eli Lilly and Company, Indianapolis, IN, USA; 2Eli Lilly and Company, Windlesham, Surrey, UK; 3Departament de Psiquiatria, Universitat Autonoma de Barcelona, Spain; 4Parc Sanitari Sant Joan de Déu, Centro de Investigación Biomédica en Red en el Área de Salud Mental, Universitat de Barcelona, Barcelona, SpainBackground: Little is known about the long-term changes in the functioning of schizophrenia patients receiving maintenance therapy with olanzapine long-acting injection (LAI, and whether observed changes differ from those seen with oral olanzapine.Methods: This study describes changes in the levels of functioning among outpatients with schizophrenia treated with olanzapine-LAI compared with oral olanzapine over 2 years. This was a secondary analysis of data from a multicenter, randomized, open-label, 2-year study comparing the long-term treatment effectiveness of monthly olanzapine-LAI (405 mg/4 weeks; n=264 with daily oral olanzapine (10 mg/day; n=260. Levels of functioning were assessed with the Heinrichs–Carpenter Quality of Life Scale. Functional status was also classified as “good”, “moderate”, or “poor”, using a previous data-driven approach. Changes in functional levels were assessed with McNemar’s test and comparisons between olanzapine-LAI and oral olanzapine employed the Student’s t-test. Results: Over the 2-year study, the patients treated with olanzapine-LAI improved their level of functioning (per Quality of Life total score from 64.0–70.8 (P<0.001. Patients on oral ­olanzapine also increased their level of functioning from 62.1–70.1 (P<0.001. At baseline, 19.2% of the olanzapine-LAI-treated patients had a “good” level of functioning, which increased to 27.5% (P<0.05. The figures for oral olanzapine were 14.2% and 24.5%, respectively (P<0.001. Results did not significantly differ between

  5. Experimental investigation and combustion analysis of a direct injection dual-fuel diesel-natural gas engine

    Energy Technology Data Exchange (ETDEWEB)

    Carlucci, A.P.; De Risi, A.; Laforgia, D.; Naccarato, F. [Department of Engineering for Innovation, University of Salento, CREA, via per Arnesano, 73100 Lecce (Italy)

    2008-02-15

    A single-cylinder diesel engine has been converted into a dual-fuel engine to operate with natural gas together with a pilot injection of diesel fuel used to ignite the CNG-air charge. The CNG was injected into the intake manifold via a gas injector on purpose designed for this application. The main performance of the gas injector, such as flow coefficient, instantaneous mass flow rate, delay time between electrical signal and opening of the injector, have been characterized by testing the injector in a constant-volume optical vessel. The CNG jet structure has also been characterized by means of shadowgraphy technique. The engine, operating in dual-fuel mode, has been tested on a wide range of operating conditions spanning different values of engine load and speed. For all the tested operating conditions, the effect of CNG and diesel fuel injection pressure, together with the amount of fuel injected during the pilot injection, were analyzed on the combustion development and, as a consequence, on the engine performance, in terms of specific emission levels and fuel consumption. (author)

  6. Field Test Program for Long-Term Operation of a COHPAC System for Removing Mercury from Coal-Fired Flue Gas

    Energy Technology Data Exchange (ETDEWEB)

    C. Jean Bustard; Charles Lindsey; Paul Brignac

    2006-05-01

    This document provides a summary of the full-scale demonstration efforts involved in the project ''Field Test Program for Long-Term Operation of a COHPAC{reg_sign} System for Removing Mercury from Coal-Fired Flue Gas''. The project took place at Alabama Power's Plant Gaston Unit 3 and involved the injection of sorbent between an existing particulate collector (hot-side electrostatic precipitators) and a COHPAC{reg_sign} fabric filter (baghouse) downstream. Although the COHPAC{reg_sign} baghouse was designed originally for polishing the flue gas, when activated carbon injection was added, the test was actually evaluating the EPRI TOXECON{reg_sign} configuration. The results from the baseline tests with no carbon injection showed that the cleaning frequency in the COHPAC{reg_sign} unit was much higher than expected, and was above the target maximum cleaning frequency of 1.5 pulses/bag/hour (p/b/h), which was used during the Phase I test in 2001. There were times when the baghouse was cleaning continuously at 4.4 p/b/h. In the 2001 tests, there was virtually no mercury removal at baseline conditions. In this second round of tests, mercury removal varied between 0 and 90%, and was dependent on inlet mass loading. There was a much higher amount of ash exiting the electrostatic precipitators (ESP), creating an inlet loading greater than the design conditions for the COHPAC{reg_sign} baghouse. Tests were performed to try to determine the cause of the high ash loading. The LOI of the ash in the 2001 baseline tests was 11%, while the second baseline tests showed an LOI of 17.4%. The LOI is an indication of the carbon content in the ash, which can affect the native mercury uptake, and can also adversely affect the performance of ESPs, allowing more ash particles to escape the unit. To overcome this, an injection scheme was implemented that balanced the need to decrease carbon injection during times when inlet loading to the baghouse was high and

  7. Do cervical epidural injections provide long-term relief in neck and upper extremity pain? A systematic review.

    Science.gov (United States)

    Manchikanti, Laxmaiah; Nampiaparampil, Devi E; Candido, Kenneth D; Bakshi, Sanjay; Grider, Jay S; Falco, Frank J E; Sehgal, Nalini; Hirsch, Joshua A

    2015-01-01

    The high prevalence of chronic persistent neck pain not only leads to disability but also has a significant economic, societal, and health impact. Among multiple modalities of treatments prescribed in the management of neck and upper extremity pain, surgical, interventional and conservative modalities have been described. Cervical epidural injections are also common modalities of treatments provided in managing neck and upper extremity pain. They are administered by either an interlaminar approach or transforaminal approach. To determine the long-term efficacy of cervical interlaminar and transforaminal epidural injections in the treatment of cervical disc herniation, spinal stenosis, discogenic pain without facet joint pain, and post surgery syndrome. The literature search was performed from 1966 to October 2014 utilizing data from PubMed, Cochrane Library, US National Guideline Clearinghouse, previous systematic reviews, and cross-references. The evidence was assessed based on best evidence synthesis with Level I to Level V. There were 7 manuscripts meeting inclusion criteria. Of these, 4 assessed the role of interlaminar epidural injections for managing disc herniation or radiculitis, and 3 assessed these injections for managing central spinal stenosis, discogenic pain without facet joint pain, and post surgery syndrome. There were 4 high quality manuscripts. A qualitative synthesis of evidence showed there is Level II evidence for each etiology category. The evidence is based on one relevant, high quality trial supporting the efficacy of cervical interlaminar epidural injections for each particular etiology. There were no randomized trials available assessing the efficacy of cervical transforaminal epidural injections. Paucity of available literature, specifically conditions other than disc herniation. This systematic review with qualitative best evidence synthesis shows Level II evidence for the efficacy of cervical interlaminar epidural injections with local

  8. Forecast of thermal-hydrological conditions and air injection test results of the single heater test at Yucca Mountain

    International Nuclear Information System (INIS)

    Birkholzer, J.T.; Tsang, Y.W.

    1996-12-01

    The heater in the Single Heater Test (SHT) in alcove 5 of the Exploratory Studies Facility (ESF) was turned on August 26, 1996. A large number of sensors are installed in the various instrumented boreholes to monitor the coupled thermal-hydrological-mechanical-chemical responses of the rock mass to the heat generated in the single heater. In this report the authors present the results of the modeling of both the heating and cooling phases of the Single Heater Test (SHT), with focus on the thermal-hydrological aspect of the coupled processes. Also in this report, the authors present simulations of air injection tests will be performed at different stages of the heating and cooling phase of the SHT

  9. Trapping of gun-injected plasma by a tokamak

    International Nuclear Information System (INIS)

    Leonard, A.W.; Dexter, R.N.; Sprott, J.C.

    1986-10-01

    It is shown that a plasma produced by a Marshall gun can be injected into and trapped by a tokamak plasma. Gun injection raises the line-averaged density and peaks the density profile. Trapping of the gun-injected plasma is explainable in terms of a depolarization current mechanism. A model is developed which describes the slowing of a plasma beam crossing into the magnetic field of a tokamak. The slowing down time is shown to go as tau/sub s/ ∞ n -1 /sub b/T 3 /sub e/(α 0 /L) 2 , where n/sub b/ and T/sub e/ are the density and temperature of the plasma beam and α 0 /L is the pitch of the field lines per unit length in the direction in which the beam is traveling. Experimental tests of this model are consistent with the scaling predictions

  10. Long term testing of PSI-membranes

    Energy Technology Data Exchange (ETDEWEB)

    Huslage, J; Brack, H P; Geiger, F; Buechi, F N; Tsukada, A; Scherer, G G [Paul Scherrer Inst. (PSI), Villigen (Switzerland)

    1999-08-01

    Long term tests of PSI membranes based on radiation-grafted FEP and ETFE films were carried out and FEP-based membranes were evaluated by monitoring the in-situ membrane area resistance measured by a current pulse method. By modifying our irradiation procedure and using the double crosslinking concept we obtain reproducible membrane cell lifetimes (in term of in-situ membrane resistance) of greater than 5000 hours at 60-65{sup o}C. Preliminary tests at 80-85{sup o}C with lifetimes of greater than 2500 demonstrate the potential long term stability of PSI proton exchange membranes based on FEP over the whole operating temperature range of low-temperature polymer electrolyte fuel cells. Radiation grafted PSI membranes based on ETFE have better mechanical properties than those of the FEP membranes. Mechanical properties are particularly important in large area cells and fuel cell stacks. ETFE membranes have been tested successfully for approximately 1000 h in a 2-cell stack (100 cm{sup 2} active area each cell). (author) 4 figs., 4 refs.

  11. Impact of iodized oil injection during pregnancy on thyroid function tests of offspring

    International Nuclear Information System (INIS)

    Saadat, N.; Sheikholeslam, R.; Azizi, F.

    2002-01-01

    Previous studies have shown that injection of iodized oil in pregnant women can be used as a prophylactic strategy for iodine deficiency disorders and may improve the growth indices of their offspring. Since administration of pharmacological doses of iodine may lead occasionally to large goiter and rarely to hypothyroidism, in the present study the thyroid function tests of neonates and infants born to women who had received 480 mg iodized oil intramuscularly during pregnancy were assessed and compared to those of a control group. Off 277 cord blood samples obtained from Mazandaran and Khohkiluyeh-Boyerahmad provinces, 125 made up the case (injected) and 152 the control (non-injected) group. Of 1026 blood samples of the neonates and infants from Mazandaran province. 544 made up the case and 482 the control group. Serum T 4 , T 3 and TSH concentrations were measured with RIA kits. in the cord blood samples, mean serum T 4 in cases who had received iodized oil was lower than that of the control group:140± 32 vs. 149± 33 nmol/L, respectively; p 3 and TSH were not however different. In the neonates and infants, T 4 and T 3 concentrations were significantly higher in the case than control group:178± 40 vs. 168± and 3.5±0,02 nmol/L, respectively, both p 3 and decreased TSH were seen in infants of mothers who were injected in the second and third trimesters of pregnancy. Injection of iodized oil in pregnant women does not cause hypothyroidism in the offsprings, however it does cause a transient increase in serum thyroid hormones and a decrease in TSH concentrations

  12. Long-term bioventing performance in low-permeability soils

    International Nuclear Information System (INIS)

    Phelps, M.B.; Stanin, F.T.; Downey, D.C.

    1995-01-01

    Short-term and long-term bioventing treatability testing has shown that in situ air injection and extraction is a practical method for sustaining increased oxygen levels and enhancing aerobic biodegradation of petroleum hydrocarbons in low-permeability soils. At several test sites, initial physical parameter analysis of soils and air permeability tests indicated that impacted soils (fine sandy silts and clays) had low air permeabilities. Measurements of depleted soil-gas oxygen levels and increased soil-gas carbon dioxide levels indicated that the natural process of aerobic biodegradation of petroleum hydrocarbons was oxygen-limited. Initial treatability testing consisted of air permeability tests to measure the permeability of the soils to air and in situ respiration tests to measure the rates at which native microorganisms could biodegrade the contaminants when provided with sufficient oxygen. During the long-term treatment period, active air injection or extraction systems were operated for 1 year or longer. Soil gas was periodically monitored within the treatment zone to evaluate the success of the bioventing systems in increasing soil-gas oxygen levels in the low-permeability soils. Follow-up respiration tests and soil and soil-gas sampling were conducted to evaluate changes in respiration rates and contaminant concentrations with time

  13. Long-term results of percutaneous ethanol injection therapy for hepatocellular carcinoma in cirrhosis: a European experience

    International Nuclear Information System (INIS)

    Lencioni, R.; Pinto, F.; Armillotta, N.; Bassi, A.M.; Moretti, M.; Di Giulio, M.; Marchi, S.; Uliana, M.; Della Capanna, S.; Lencioni, M.; Bartolozzi, C.

    1997-01-01

    The objective of our work was to evaluate the long-term results of percutaneous ethanol injection (PEI) for the treatment of hepatocellular carcinoma (HCC) in patients with liver cirrhosis. A total of 184 cirrhotic patients with HCC underwent PEI as the only anticancer treatment over an 8-year period. Patients were followed after therapy by means of clinical examinations, laboratory tests, and US and CT studies performed at regular time intervals. Survival rates were determined according to the Kaplan-Meier method. The overall survival was 67% at 3 years, 41% at 5 years, and 19% at 7 years. The 3-, 5-, and 7-year survival rates of patients with single HCC≤3 cm (78, 54, and 28%, respectively) were significantly higher (p<0.01) than those of patients with single HCC of 3.1-5 cm (61, 32, and 16, respectively) or multiple HCCs (51, 21, and 0%, respectively). Survival of Child-Pugh A patients (79% at 3 years, 53% at 5 years, and 32% at 7 years) was significantly longer (p<0.01) than that of Child-Pugh B patients (50% at 3 years, 28% at 5 years, and 8% at 7 years). A selected group of 70 patients with Child-Pugh A cirrhosis and single HCC≤3 cm had a 7-year survival of 42%. Long-term survival of cirrhotic patients with HCC treated with PEI is comparable to that reported in published series of matched patients submitted to surgical resection. (orig.)

  14. Comparison of in-plant performance test data with analytic prediction of reactor safety system injection transient (U)

    International Nuclear Information System (INIS)

    Roy, B.N.; Neill, C.H. Jr.

    1993-01-01

    This paper compares the performance test data from injection transients for both of the subsystems of the Supplementary Safety System of the Savannah River Site production reactor with analytical predictions from an in-house thermal hydraulic computer code. The code was initially developed for design validation of the new Supplementary Safety System subsystem, but is shown to be equally capable of predicting the performance of the Supplementary Safety System existing subsystem even though the two subsystem transient injections have marked differences. The code itself was discussed and its validation using prototypic tests with simulated fluids was reported in an earlier paper (Roy and Nomm 1991)

  15. Automatic monitoring of radial injection tracer tests using a novel multi-electrode resistivity system

    International Nuclear Information System (INIS)

    Ward, R.S.; Sen, M.A.; Williams, G.M.; Jackson, P.D.

    1990-01-01

    A radial injection tracer test has been carried out in an unconfined fluvial sand and gravel aquifer underlain by low permeability clay. Sodium chloride has been used as an electrolyte tracer and breakthrough has been monitored using a newly developed automatic resistivity system (RESCAN) incorporating six fully penetrating resistivity probes each having 80 electrodes spaced at 5 cm intervals along their length. Each electrode is individually addressable under computer control to either carry current or measure potential. Any four electrodes can be selected in the traditional Wenner configuration to measure formation resistivity. Rapid measurement of changes in resistivity allows a very detailed picture of tracer migration to be obtained. The resistivity probes were placed at 1 and 2 m radii from the central fully-screened tracer injection well along three limbs at 120 degrees. Resistivity measurements were compared with adjacent multi-level samplers. An 8 x 8 m grid of 140 surface electrodes centred on the central well was also installed. The resistivity profiles measured prior to tracer injection were used to infer lithology, particularly layering. Detailed breakthrough curves were obtained at 77 positions along each of the six probes and compared with adjacent multi-level sampler breakthrough curves. The results showed that the aquifer was extremely heterogeneous even on this small scale. Because the system operates automatically without the need to extract and analyse large numbers of water samples, it opens up the possibility of carrying out lots of small scale injection tests within a larger domain likely to be invaded by a tracer or pollution plume. Such detailed information for determining aquifer properties can provide the data set necessary for characterisation of the aquifer to predict dispersion parameters appropriate to the large scale. (Author) (6 refs., 9 figs., 2 tabs.)

  16. The concept of "compartment allergy": prilocaine injected into different skin layers

    Directory of Open Access Journals (Sweden)

    Wobser Marion

    2011-04-01

    Full Text Available Abstract We herein present a patient with delayed-type allergic hypersensitivity against prilocaine leading to spreading eczematous dermatitis after subcutaneous injections for local anesthesia with prilocaine. Prilocaine allergy was proven by positive skin testing and subcutaneous provocation, whereas the evaluation of other local anesthetics - among them lidocaine, articaine and mepivacaine - did not exhibit any evidence for cross-reactivity. Interestingly, our patient repeatedly tolerated strictly deep subcutaneous injection of prilocaine in provocation testing while patch and superficial subcutaneous application mounted strong allergic responses. We hypothesize, that lower DC density in deeper cutaneous compartments and/or different DC subsets exhibiting distinct functional immunomodulatory properties in the various layers of the skin may confer to the observed absence of clinical reactivity against prilocaine after deep subcutaneous injection. The term compartment allergy indicates that the route of allergen administration together with the targeted immunologic environment orchestrates on the immunologic outcome: overt T-cell mediated allergy or clinical tolerance.

  17. TEST DESIGN FOR ENVIRONMENTAL TECHNOLOGY VERIFICATION (ETV) OF ADD-ON NOX CONTROL UTILIZING OZONE INJECTION

    Science.gov (United States)

    The paper discusses the test design for environmental technology verification (ETV) of add-0n nitrogen oxides (NOx) control utilizing ozone injection. (NOTE: ETV is an EPA-established program to enhance domestic and international market acceptance of new or improved commercially...

  18. Systemic or Intra-Amygdala Injection of a Benzodiazepine (Midazolam) Impairs Extinction but Spares Re-Extinction of Conditioned Fear Responses

    Science.gov (United States)

    Hart, Genevra; Harris, Justin A.; Westbrook, R. Frederick

    2009-01-01

    Rats were subjected to one or two cycles of fear conditioning and extinction, injected with a benzodiazepine, midazolam, before the first or second extinction, and tested for long-term inhibition of fear responses (freezing). In Experiment 1, inhibition of context-conditioned fear was spared when midazolam was injected before the second…

  19. Fault injection as a test method for an FPGA in charge of data readout for a large tracking detector

    CERN Document Server

    Roed, K; Richter, M; Fehlker, D; Helstrup, H; Alme, J; Ullaland, K

    2011-01-01

    This paper describes how fault injection has been implemented as a test method for an FPGA in an existing hardware configuration setup. As this FPGA is in charge of data readout for a large tracking detector, the reliability of this FPGA is of high importance. Due to the complexity of the readout electronics, irradiation testing is technically difficult at this stage of the system commissioning. The work presented in this paper is therefore motivated by introducing fault injection as an alternative method to characterize failures caused by SEUs. It is a method to study the effect that a configuration upset may have on the operation of the FPGA. The target platform consists of two independent modules for data acquisition and detector control functionality. Fault injection to test the response of the data acquisition module is made possible by implementing the solution as part of the detector control functionality. Correct implementation is validated by a simple shift register design. Our results demonstrate th...

  20. Theoretical considerations of Flow Injection Analysis in the Absence of Chemical Reactions

    DEFF Research Database (Denmark)

    Andersen, Jens Enevold Thaulov

    2000-01-01

    The fundamental mechanism of flow injection analysis (FIA) is assumed to be simple dissusion and the response of the detector is included in a model description that provide information about the shape of the FIA peak in terms of, basically, five parameters. Two of the five parameters are associa...... that any deviation from the features of the present model and the results of a tentative chemical reaction with one of the test compounds, is related to chemical kinetics.......The fundamental mechanism of flow injection analysis (FIA) is assumed to be simple dissusion and the response of the detector is included in a model description that provide information about the shape of the FIA peak in terms of, basically, five parameters. Two of the five parameters...

  1. Single well injection withdrawal tests (SWIW) in fractured rock. Some aspects on interpretation

    International Nuclear Information System (INIS)

    Neretnieks, Ivars

    2007-08-01

    Single-Well-Injection-Withdrawal, SWIW, tests are used to try to extract information on fracture apertures, sorption and diffusion properties and dispersion information in individual fractures. It is done by injecting a given amount of traced water into an isolated fracture. After a waiting period water is withdrawn from the fracture and the tracer concentration is measured. The concentration time curve is fitted to a model and the parameter values quantifying the different interaction mechanisms are determined. A number of different mechanisms influence the recovery of the tracer. One or more of the following mechanisms are considered. They include: dispersion due to velocity differences, sorption on fracture surface and on infill, diffusion in rock fragments in the fracture, diffusion between 'streamlines', diffusion into rock matrix and other stagnant water volumes, sorption kinetics and slow drift of the plume caused by the natural gradient. Many of the interaction mechanisms can influence the recovery curve in a similar way. For example, diffusion into rock matrix water and into stagnant water in the fracture adjacent to the flowing channels cannot be distinguished if only one tracer is used. Tracers with different properties can in principle be used but they will encounter different parts of the fracture, the sorbing tracer will move out less from the injection point than a nonsorbing tracer will. Diffusion and sorption in small particles in the flowpath can influence the recovery curve in a similar way as rock matrix diffusion does. Dispersion caused by diffusion between 'streamlines', Taylor dispersion, can give very different results in channels of different shapes. Such dispersion effects can be difficult to distinguish from matrix diffusion effects. Dispersion coefficients obtained in a SWIW test may have little relation to dispersion of a tracer moving from A to B. This is partly due to the different mechanisms and partly due to different time scales

  2. Single well injection withdrawal tests (SWIW) in fractured rock. Some aspects on interpretation

    Energy Technology Data Exchange (ETDEWEB)

    Neretnieks, Ivars [Dept. of Chemical Engineering and Technology, Royal Inst. of Technology, Stockholm (Sweden)

    2007-08-15

    Single-Well-Injection-Withdrawal, SWIW, tests are used to try to extract information on fracture apertures, sorption and diffusion properties and dispersion information in individual fractures. It is done by injecting a given amount of traced water into an isolated fracture. After a waiting period water is withdrawn from the fracture and the tracer concentration is measured. The concentration time curve is fitted to a model and the parameter values quantifying the different interaction mechanisms are determined. A number of different mechanisms influence the recovery of the tracer. One or more of the following mechanisms are considered. They include: dispersion due to velocity differences, sorption on fracture surface and on infill, diffusion in rock fragments in the fracture, diffusion between 'streamlines', diffusion into rock matrix and other stagnant water volumes, sorption kinetics and slow drift of the plume caused by the natural gradient. Many of the interaction mechanisms can influence the recovery curve in a similar way. For example, diffusion into rock matrix water and into stagnant water in the fracture adjacent to the flowing channels cannot be distinguished if only one tracer is used. Tracers with different properties can in principle be used but they will encounter different parts of the fracture, the sorbing tracer will move out less from the injection point than a nonsorbing tracer will. Diffusion and sorption in small particles in the flowpath can influence the recovery curve in a similar way as rock matrix diffusion does. Dispersion caused by diffusion between 'streamlines', Taylor dispersion, can give very different results in channels of different shapes. Such dispersion effects can be difficult to distinguish from matrix diffusion effects. Dispersion coefficients obtained in a SWIW test may have little relation to dispersion of a tracer moving from A to B. This is partly due to the different mechanisms and partly due to

  3. Injection and lessons for 2012

    International Nuclear Information System (INIS)

    Bracco, C.; Barnes, M.J.; Bartmann, W.; Cornelis, K.; Drosdal, L.N.; Goddard, B.; Kain, V.; Meddahi, M.; Mertens, V.; Uythoven, J.

    2012-01-01

    Injection of 144 bunches into the LHC became fully operational during the 2011 run and one nominal injection of 288 bunches was accomplished. Several mitigation solutions were put in place to minimise losses from the Transfer Line (TL) collimators and losses from kicking de-bunched beam during injection. Nevertheless, shot-by- shot and bunch-by-bunch trajectory variations, as well as long terms drifts, were observed and required a regular re-steering of the TL implying a non negligible amount of time spent for injection setup. Likely sources of instability have been identified (i.e. MKE and MSE ripples) and possible cures to optimise 2012 operation are presented. Well defined references for TL steering will be defined in a more rigorous way in order to allow a more straightforward and faster injection setup. Encountered and potential issues of the injection system, in particular the injection kickers MKI, are discussed also in view of injections with a higher number of bunches. (authors)

  4. Injection and lessons for 2012

    CERN Document Server

    Bracco, C; Bartmann, W; Cornelis, K; Drosdal, L N; Goddard, B; Kain, V; Meddahi, M; Mertens, V; Uythoven, J

    2012-01-01

    Injection of 144 bunches into the LHC became fully operational during the 2011 run and a nominal injection of 288 bunches was accomplished during MD time. Several mitigation solutions were put in place to minimise losses from the transfer line (TL) collimators and losses from kicking debunched beam during injection. Nevertheless, shot-by-shot and bunch-by-bunch trajectory variations, as well as long terms drifts, were observed and required a regular resteering of the TL implying a non negligible amount of time spent for injection setup. Likely sources of instability have been identified (i.e. MKE and MSE ripples) and possible cures to optimise 2012 operation are presented. Well defined references for TL steering will be defined in a more rigorous way in order to allow a more straightforward and faster injection setup. Encountered and potential issues of the injection system, in particular the injection kickers MKI, are discussed also in view of injections with a higher number of bunches.

  5. Steroid injections in the treatment of humeral unicameral bone cysts: long-term follow-up and review of the literature.

    Science.gov (United States)

    Pavone, V; Caff, G; Di Silvestri, C; Avondo, S; Sessa, G

    2014-05-01

    Retrospective evaluation of long-term effectiveness of the steroid injections treatment in patients with unicameral bone cysts (UBC). From January 1993 to April 2005, 23 children affected by proximal humeral UBC were evaluated according to the Neer-Cole classification system and treated with serial methylprednisolone acetate's injections. The patients were followed up at 1, 3, 6 and 12 months and then every year until the adolescence. After treatment, in 15 out of 23 patients (65.2%), the humeral cysts were referred, respectively, as Grade 1 and in four as Grade 2. In 4 patients, a refracture occurred. Statistical analysis showed an overall good response in 82.6% of patients at the end of the follow-up. Minor complication including skin discoloration accounted for 13.04%. The steroid injections showed to be an alternative excellent treatment for UBC, with complete healing of the lesions in the majority of cases. This procedure is not expensive, mini-invasive, with low surgical risk and short hospitalization.

  6. Prediction of the extent of formation damage caused by water injection

    Energy Technology Data Exchange (ETDEWEB)

    Al-Homadhi, Emad S. [King Saud Univ., Riyadh (Saudi Arabia). Petroleum Engineering Dept.

    2013-06-15

    As a general practice water is injected along the O/W contact to maintain reservoir pressure during production. Down hole analysis of the injected water shows that, even after surface treatment, it still can contain a considerable amount of solid particles. These particles can bridge formation pores and cause a considerable reduction in the injectivity. To ensure good injectivity over a longer term, the concentration and size of these solids should not exceed certain limits. In this article core flood tests were carried out to simulate high rate injectors. The injected brine contained solid particles in different concentrations and sizes. Particle concentration was between 5 and 20 ppm and the particle mean size was between 2 and 9 {mu}m. The results were presented as damaging ratio versus pore volume injected. Contrarily to previous studies instead of using experimental results in calibrating or evaluating certain theoretical models, the results in this study were directly fitted to produce equations which can predict the extent of damage caused by injected water by knowing the mean size and concentration of the solid particles contained in that water. (orig.)

  7. Comparative study between botulinum toxin injection and partial division of puborectalis for treating anismus.

    Science.gov (United States)

    Farid, Mohamed; Youssef, Tamer; Mahdy, Tarek; Omar, Waleed; Moneim, Hesham Abdul; El Nakeeb, Ayman; Youssef, Mohamed

    2009-03-01

    The objective of this study was to compare the results of partial division of puborectalis (PDPR) versus local botulinum toxin type A (BTX-A) injection in treating patients with anismus. This prospective randomized study included 30 male patients suffering from anismus. Diagnosis was made by clinical examination, barium enema, colonoscopy, colonic transit time, anorectal manometry, balloon expulsion test, defecography, and electromyography. Patients were randomized into: group I which included 15 patients who were injected with BTX-A and group II which included 15 patients who underwent bilateral PDPR. Follow-up was conducted for about 1 year. Improvement was considered when patients returned to their normal habits. BTX-A injection achieved initial success in 13 patients (86.7%). However, long-term success persisted only in six patients (40%). This was in contrast to PDPR which achieved initial success in all patients (100%) with a long-term success in ten patients (66.6%). Recurrence was observed in seven patients (53.8%) and five patients (33.4%) following BTX-A injection and PDPR, respectively. Minor degrees of incontinence were confronted in two patients (13.3%) following PDPR. BTX-A injection seems to be successful for temporary treatment of anismus.

  8. Long-term follow-up sonography of benign cystic thyroid nodules after a percutaneous ethanol injection: the incidence of malignancy-mimicking nodules

    International Nuclear Information System (INIS)

    Park, Ji Sung; Kim, Dong Wook; Eun, Choong Ki; Choi, Seok Jin; Rho, Myung Ho

    2008-01-01

    To evaluate the incidence of malignancy-mimicking sclerosed thyroid nodules, from long-term follow-up ultrasonography (US) after an US-guided percutaneous ethanol injection (PEI). We examined 86 benign cystic thyroid nodules from 80 patients. The nodules were classified into two groups based on whether an aspiration (Group A, n = 26) or non-aspiration (Group B, n 60) of infused ethanol was performed. The final follow-up US over 12 months was performed in all patients. Of the 86 nodules, the cystic portion of 82 (95.3%) cases, from 76 patients, completely disappeared subsequent to the first follow-up US (Group A, n = 24, Group B, n = 58) (Chi-square test, ρ > 0.05). Moreover, 46 sclerosed thyroid nodules showed two or more of the 'five sonographic criteria' upon a follow-up US (Group A, n = 13, 50.0%, Group B, n = 32, 53.3%). A higher ratio of the cystic portion of the nodules was associated with a higher incidence of the 'five sonographic criteria' for malignancies detected via a follow-up US (ρ < 0.01; Student's t-test). For the long-term follow-up US, the 'five sonographic criteria' were observed in half the patients who received US-guided PEI. Also, by acknowledging the possibility that sonographic findings mimic a malignancy, since the sclerosed thyroid nodule, patients may avoid an unnecessary biopsy

  9. THE RHIC INJECTION SYSTEM.

    Energy Technology Data Exchange (ETDEWEB)

    FISCHER,W.; GLENN,J.W.; MACKAY,W.W.; PTITSIN,V.; ROBINSON,T.G.; TSOUPAS,N.

    1999-03-29

    The RHIC injection system has to transport beam from the AGS-to-RHIC transfer line onto the closed orbits of the RHIC Blue and Yellow rings. This task can be divided into three problems. First, the beam has to be injected into either ring. Second, once injected the beam needs to be transported around the ring for one turn. Third, the orbit must be closed and coherent beam oscillations around the closed orbit should be minimized. We describe our solutions for these problems and report on system tests conducted during the RHIC Sextant test performed in 1997. The system will be fully commissioned in 1999.

  10. Effect of Heat Application during Intramuscular Injection of Vitamin K in Pain Prevention in Neonates

    Directory of Open Access Journals (Sweden)

    Yadollah Zahed Pasha

    2017-06-01

    Full Text Available Background: Several modalities have been proposed to reduce procedural pain in neonates. This study was conducted to determine whether heat of a non-human source might help with pain management in infants.Methods: In this clinical trial, 40 full-term healthy neonates in their first hours of life were randomly divided into two groups of intervention and control. The control group was put under a radiant warmer using the servo-controlled method for four minutes and the temperature was set to 35.5°C. The intervention group was put under the servocontrolled mode with the temperature of 35.5°C for two minutes, then two minutes in manual mode with 100% power. Vitamin K injection was performed. The severity of pain in infants was measured by an independent observer by means of Neonatal Infant Pain Scale (NIPS before the injection, 20 seconds during the injection, as well as 60 and 120 seconds after the injection. The difference in pain score was compared between the two groups using Chi-squared test, repeated measures analysis of variance, and independent t-test.Results: The two groups were similar in terms of gestational age, birth weight, Apgar score, and maternal age. The mean of NIPS scores was 2.9 in intervention group and 4 in the control group during injection, which was significantly different (P=0.001. No significant difference was recorded in skin temperature and pain scores before and after injection.

  11. EDF plan for a dispersant injection trial

    International Nuclear Information System (INIS)

    Mercier, Stephane; Corredera, Geraldine; Alves-Vieira, Maria; Mansour, Carine; You, Dominique

    2012-09-01

    In its strategy for SG fouling control, EDF is considering the use of dispersant as a preventive remedy. A trial on Golfech 2 started in May 2012. The dispersant selected for the trial is Polyacrylic Acid (PAA). The main goals of the test are to check and quantify the gain on iron transport to blowdown, to evaluate the possible effects on secondary side chemistry and the operational costs of the injection - reactant, ion exchange resins and filters. The results of the test, if satisfying, will be used to set EDF strategy for dispersant long term use on its fleet. So, one concern about the trial is to make sure that the conclusions of this test will be applicable to a wide range of EDF plants. For that purpose, several criteria have been examined for the choice of the candidate plant such as fouling level, secondary circuit materials (presence or absence of copper alloys,...), SG tube material, thermal power margin, secondary side chemistry (amine used and pH applied). Before starting the trial, EDF had to take into account the international feedback and to adapt it to its specific requirements: the neutralization amine was switched from ETA to morpholine, additional work had been completed to validate the innocuousness of PAA injection for EDF plants... This work especially includes laboratory testing of secondary side corrosion cracking in the presence of PAA and water chemistries used in EdF plants. Moreover, investigation on the thermal stability of PAA and degradation products was completed and further evaluation of environmental impact was performed. A dedicated skid for the injection of PAA was implemented in Golfech Chemicals injection room. The installation and the process were notably designed to take into account the high viscosity of the commercial product, and the need to proceed to a good rinsing of the pipes without increasing the discharged effluents. The first available data from Golfech 2 trial are also provided and discussed. (authors)

  12. Long-term complications of polyethylene glycol injection to the face.

    Science.gov (United States)

    Altintas, Hande; Odemis, Mustafa; Bilgi, Selcuk; Cakmak, Ozcan

    2012-04-01

    Currently, filling, smoothing, or recontouring the face through the use of injectable fillers is one of the most popular forms of cosmetic surgery. Because these materials promise a more youthful appearance without anesthesia in a noninvasive way, various fillers have been used widely in different parts of the world. However, most of these fillers have not been approved by the Food and Drug Administration, and their applications might cause unpleasant disfiguring complications. This report describes a case of foreign body granuloma in the cheeks secondary to polyethylene glycol injection and shows the possible complications associated with the use of facial fillers.

  13. Evaluation of upward migration around a deep injection well

    International Nuclear Information System (INIS)

    Chia, Yeeping; Chiu, J.

    1994-01-01

    The long-term containment of injected wastes in the deep subsurface is expected to be achieved under suitable geologic and hydrologic conditions and by the use of competent engineering practices. Field experiences, however, indicate that waste containment may be affected by hydrologic conduits around the injection well. To assess the potential effects of these conduits, upward migration of injected waste is examined through the use of numerical models under various conditions. Test results indicate that without any preferential hydrologic conduits, most of the injected waste moves laterally in the injection interval, whereas only a small amount of waste migrates upward into the containment interval. When vertical fractures in the disturbed zone or defects in the cement seal around the wellbore exist, the contaminant can move rapidly upward along these conduits to an overlying aquifer, from which it migrates in the lateral direction. The contamination of the overlying aquifer that results from the upward migration of injected waste through these conduits cannot be impeded by a thick, low-permeability containment interval. However, when permeable interbeds exist within the containment interval, a significant portion of the waste migrating upward can be diverted laterally before reaching the overlying aquifer. The front of built-up pressure can reach the aquifer or permeable interbed immediately overlying the injection interval through the preferential hydrologic conduits shortly after the injection starts, but it cannot move farther upward because of pressure dissipation in the permeable formation. This study suggests that the injected waste has the potential to migrate upward into overlying formations through preferential migration conduits around the wellbore

  14. Finalize field testing of cold climate heat pump (CCHP) based on tandem vapor injection compressors

    Energy Technology Data Exchange (ETDEWEB)

    Shen, Bo [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Baxter, Van D. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Abdelaziz, Omar [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Rice, C. Keith [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-03-01

    This report describes the system diagram and control algorithm of a prototype air-source cold climate heat pump (CCHP) using tandem vapor injection (VI) compressors. The prototype was installed in Fairbanks, Alaska and underwent field testing starting in 09/2016. The field testing results of the past six months, including compressor run time fractions, measured COPs and heating capacities, etc., are presented as a function of the ambient temperature. Two lessons learned are also reported.

  15. Melt quenching and coolability by water injection from below: Co-injection of water and non-condensable gas

    International Nuclear Information System (INIS)

    Cho, Dae H.; Page, Richard J.; Abdulla, Sherif H.; Anderson, Mark H.; Klockow, Helge B.; Corradini, Michael L.

    2006-01-01

    The interaction and mixing of high-temperature melt and water is the important technical issue in the safety assessment of water-cooled reactors to achieve ultimate core coolability. For specific advanced light water reactor (ALWR) designs, deliberate mixing of the core melt and water is being considered as a mitigative measure, to assure ex-vessel core coolability. The goal of our work is to provide the fundamental understanding needed for melt-water interfacial transport phenomena, thus enabling the development of innovative safety technologies for advanced LWRs that will assure ex-vessel core coolability. The work considers the ex-vessel coolability phenomena in two stages. The first stage is the melt quenching process and is being addressed by Argonne National Lab and University of Wisconsin in modified test facilities. Given a quenched melt in the form of solidified debris, the second stage is to characterize the long-term debris cooling process and is being addressed by Korean Maritime University via test and analyses. In this paper, experiments on melt quenching by the injection of water from below are addressed. The test section represented one-dimensional flow-channel simulation of the bottom injection of water into a core melt in the reactor cavity. The melt simulant was molten lead or a lead alloy (Pb-Bi). For the experimental conditions employed (i.e., melt depth and water flow rates), it was found that: (1) the volumetric heat removal rate increased with increasing water mass flow rate and (2) the non-condensable gas mixed with the injected water had no impairing effect on the overall heat removal rate. Implications of these current experimental findings for ALWR ex-vessel coolability are discussed

  16. Effects of zinc injection from hot functional test at Tomari Unit 3

    International Nuclear Information System (INIS)

    Hayakawa, Hitoshi; Mino, Yoshitaka; Nakahama, Satoshi; Aizawa, Yamato; Shimizu, Yuichi; Umehara, Ryuji; Kogawa, Noritaka

    2012-09-01

    At Tomari Nuclear Power Station unit 3 (hereafter Tomari unit 3, PWR, commercial operation from December 2009), the zinc injection for dose-rate reduction was started as early as at the Hot Functional Test (hereafter HFT) stage, for the first time in the world. The results of the Steam Generator (hereafter SG) insert plate analysis and the ambient dose-rate measurement till the end of the test operation reported heretofore, show the formation of the robust oxide film on the primary material surfaces and the associated corrosion suppression effect, and a considerable dose-rate reduction of about 40 to 60% lower than a reference plant. (*: Asian Water Chemistry Symposium in Nagoya on 2009 and NPC2010 in Canada). The material of SG tube is Alloy 690TT in Tomari unit 3. Generally, the dose-rates of the plants with Alloy 690TT SG are the highest at the 1. or 2. refueling outage (hereafter RFO), due to the effects of the Ni dissolution from the initial corrosion of Alloy 690TT. Therefore, the dose-rate of Tomari unit 3 at the 1. RFO is compared with those of the other Japanese PWR plants at their 1. RFO. As the result, the dose-rates inside the main components such as SG, Main Coolant Pipe (hereafter MCP) and Reactor Vessel (hereafter RV) are about 50% lower at the 1. RFO of Tomari unit 3 than those of a reference plant (a 3-Loop PWR plant in Japan). Therefore, an additional dose-rate reduction effects is expected by the Ni release rate reduction from Alloy 690TT and the effect of zinc injection. In this report, the actual dose-rates at the primary main components, the trends of the water chemistry and dose rates reduction effect with the zinc injection at the 1. RFO (offline in January 2011) of Tomari unit 3 are introduced. Also, a part of the experiences at the 2. RFO (offline in May 2012) is introduced. (authors)

  17. SHORT-TERM MEMORY IS INDEPENDENT OF BRAIN PROTEIN SYNTHESIS

    Energy Technology Data Exchange (ETDEWEB)

    Davis, Hasker P.; Rosenzweig, Mark R.; Jones, Oliver W.

    1980-09-01

    Male Swiss albino CD-1 mice given a single injection of a cerebral protein synthesis inhibitor, anisomycin (ANI) (1 mg/animal), 20 min prior to single trial passive avoidance training demonstrated impaired retention at tests given 3 hr, 6 hr, 1 day, and 7 days after training. Retention was not significantly different from saline controls when tests were given 0.5 or 1.5 hr after training. Prolonging inhibition of brain protein synthesis by giving either 1 or 2 additional injections of ANI 2 or 2 and 4 hr after training did not prolong short-term retention performance. The temporal development of impaired retention in ANI treated mice could not be accounted for by drug dosage, duration of protein synthesis inhibition, or nonspecific sickness at test. In contrast to the suggestion that protein synthesis inhibition prolongs short-term memory (Quinton, 1978), the results of this experiment indicate that short-term memory is not prolonged by antibiotic drugs that inhibit cerebral protein synthesis. All evidence seems consistent with the hypothesis that short-term memory is protein synthesis independent and that the establishment of long-term memory depends upon protein synthesis during or shortly after training. Evidence for a role of protein synthesis in memory maintenance is discussed.

  18. Phobia of self-injecting and self-testing in insulin-treated diabetes patients: opportunities for screening

    NARCIS (Netherlands)

    Mollema, E. D.; Snoek, F. J.; Heine, R. J.; van der Ploeg, H. M.

    2001-01-01

    To define clinically relevant cut-off points for severe fear of self-injecting (FSI) and self-testing (FST) (phobia) in insulin-treated patients with diabetes, and to estimate the magnitude of these phobias in our research population. FSI and FST were assessed in a cross-sectional survey using the

  19. Vibration of safety injection pump motors

    Energy Technology Data Exchange (ETDEWEB)

    Wattrelos, D.

    1996-12-01

    This paper covers a fault encountered in the safety injection pump motors of the French 900 MWe unit nuclear power stations. This fault was not revealed either during the low pressure safety injection and containment spray system pump qualification tests under accident conditions or during the special tests on a test bench carried out to attempt to replicate the fault and to identify ways of remedying it. This constitutes a potential common mode of failure of the safety injection system and the containment spray system pumps. The vibration phenomena illustrate the importance of carrying out tests in the plants under conditions as close as possible to those of actual accident situations.

  20. Vibration of safety injection pump motors

    International Nuclear Information System (INIS)

    Wattrelos, D.

    1996-01-01

    This paper covers a fault encountered in the safety injection pump motors of the French 900 MWe unit nuclear power stations. This fault was not revealed either during the low pressure safety injection and containment spray system pump qualification tests under accident conditions or during the special tests on a test bench carried out to attempt to replicate the fault and to identify ways of remedying it. This constitutes a potential common mode of failure of the safety injection system and the containment spray system pumps. The vibration phenomena illustrate the importance of carrying out tests in the plants under conditions as close as possible to those of actual accident situations

  1. Vibration of safety injection pump motors

    International Nuclear Information System (INIS)

    Wattrelos, D.

    1997-01-01

    This paper covers a fault encountered in the safety injection pump motors of the French 900 MWe unit nuclear power stations. This fault was not revealed either during the low pressure safety injection and containment spray system pump qualification test under accident conditions or during the special tests on a test bench carried out to attempt to replicate the fault and to identify ways of remedying it. This constitutes a potential common mode of failure of the safety injection system and the containment spray system pumps. The vibration phenomena illustrate the importance of carrying out test in the plants under conditions as close as possible to those of actual accident. (author)

  2. Large scale gas injection test (Lasgit) performed at the Aespoe Hard Rock Laboratory. Summary report 2008

    International Nuclear Information System (INIS)

    Cuss, R.J.; Harrington, J.F.; Noy, D.J.

    2010-02-01

    This report describes the set-up, operation and observations from the first 1,385 days (3.8 years) of the large scale gas injection test (Lasgit) experiment conducted at the Aespoe Hard Rock Laboratory. During this time the bentonite buffer has been artificially hydrated and has given new insight into the evolution of the buffer. After 2 years (849 days) of artificial hydration a canister filter was identified to perform a series of hydraulic and gas tests, a period that lasted 268 days. The results from the gas test showed that the full-scale bentonite buffer behaved in a similar way to previous laboratory experiments. This confirms the up-scaling of laboratory observations with the addition of considerable information on the stress responses throughout the deposition hole. During the gas testing stage, the buffer was continued to artificially hydrate. Hydraulic results, from controlled and uncontrolled events, show that the buffer continues to mature and has yet to reach full maturation. Lasgit has yielded high quality data relating to the hydration of the bentonite and the evolution in hydrogeological properties adjacent to the deposition hole. The initial hydraulic and gas injection tests confirm the correct working of all control and data acquisition systems. Lasgit has been in successful operation for in excess of 1,385 days

  3. Large scale gas injection test (Lasgit) performed at the Aespoe Hard Rock Laboratory. Summary report 2008

    Energy Technology Data Exchange (ETDEWEB)

    Cuss, R.J.; Harrington, J.F.; Noy, D.J. (British Geological Survey (United Kingdom))

    2010-02-15

    This report describes the set-up, operation and observations from the first 1,385 days (3.8 years) of the large scale gas injection test (Lasgit) experiment conducted at the Aespoe Hard Rock Laboratory. During this time the bentonite buffer has been artificially hydrated and has given new insight into the evolution of the buffer. After 2 years (849 days) of artificial hydration a canister filter was identified to perform a series of hydraulic and gas tests, a period that lasted 268 days. The results from the gas test showed that the full-scale bentonite buffer behaved in a similar way to previous laboratory experiments. This confirms the up-scaling of laboratory observations with the addition of considerable information on the stress responses throughout the deposition hole. During the gas testing stage, the buffer was continued to artificially hydrate. Hydraulic results, from controlled and uncontrolled events, show that the buffer continues to mature and has yet to reach full maturation. Lasgit has yielded high quality data relating to the hydration of the bentonite and the evolution in hydrogeological properties adjacent to the deposition hole. The initial hydraulic and gas injection tests confirm the correct working of all control and data acquisition systems. Lasgit has been in successful operation for in excess of 1,385 days

  4. Injectable barriers for waste isolation

    International Nuclear Information System (INIS)

    Persoff, P.; Finsterle, S.; Moridis, G.J.; Apps, J.; Pruess, K.; Muller, S.J.

    1995-03-01

    In this paper the authors report laboratory work and numerical simulation done in support of development and demonstration of injectable barriers formed from either of two fluids: colloidal silica or polysiloxane. Two principal problems addressed here are control of gel time and control of plume emplacement in the vadose zone. Gel time must be controlled so that the viscosity of the barrier fluid remains low long enough to inject the barrier, but increases soon enough to gel the barrier in place. During injection, the viscosity must be low enough to avoid high injection pressures which could uplift or fracture the formation. To test the grout gel time in the soil, the injection pressure was monitored as grouts were injected into sandpacks. When grout is injected into the vadose zone, it slumps under the influence of gravity, and redistributes due to capillary forces as it gels. The authors have developed a new module for the reservoir simulator TOUGH2 to model grout injection into the vadose zone, taking into account the increase of liquid viscosity as a function of gel concentration and time. They have also developed a model to calculate soil properties after complete solidification of the grout. The numerical model has been used to design and analyze laboratory experiments and field pilot tests. The authors present the results of computer simulations of grout injection, redistribution, and solidification

  5. Use of remifentanil to reduce propofol injection pain and the required propofol dose in upper digestive tract endoscopy diagnostic tests.

    Science.gov (United States)

    Uliana, Gustavo Nadal; Tambara, Elizabeth Milla; Baretta, Giorgio Alfredo Pedroso

    2015-01-01

    The introduction of propofol (2,6-diisopropylphenol) as a sedative agent has transformed the area of sedation for endoscopic procedures. However, a major drawback of sedation with the use of propofol is its high incidence of injection pain. The most widely used technique in reducing propofol injection pain is through the association of other drugs. The aim of this study was to evaluate the effect of remifentanil-propofol combination on the incidence of propofol injection pain and its influence on the total dose of propofol required for sedation in upper digestive tract endoscopy (UDE) diagnostic tests. One hundred and five patients undergoing upper digestive tract endoscopy were evaluated and randomly divided into 3 groups of 35 patients each. The Control Group received propofol alone; Study-group 1 received remifentanil at a fixed dose of 0.2mg/kg combined with propofol; Study-group 2 received remifentanil at a fixed dose of 0.3mg/kg combined with propofol. The incidence of propofol injection pain and the total dose of propofol required for the test were evaluated. The sample was very similar regarding age, weight, height, sex, and physical status. Statistical analysis was performed according to the nature of the evaluated data. Student's t-test was used to compare the mean of age, weight, height (cm), and dose (mg/kg) variables between groups. The χ(2) test was used to compare sex, physical status, and propofol injection pain between groups. The significance level was αpain and total dose of propofol (mg/kg) used. However, there were no statistical differences between the two study groups for these parameters. We conclude that the use of remifentanil at doses of 0.2mg/kg and 0.3mg/kg was effective for reducing both the propofol injection pain and the total dose of propofol used. Copyright © 2015 Sociedade Brasileira de Anestesiologia. Published by Elsevier Editora Ltda. All rights reserved.

  6. A contoured gap coaxial plasma gun with injected plasma armature.

    Science.gov (United States)

    Witherspoon, F Douglas; Case, Andrew; Messer, Sarah J; Bomgardner, Richard; Phillips, Michael W; Brockington, Samuel; Elton, Raymond

    2009-08-01

    A new coaxial plasma gun is described. The long term objective is to accelerate 100-200 microg of plasma with density above 10(17) cm(-3) to greater than 200 km/s with a Mach number above 10. Such high velocity dense plasma jets have a number of potential fusion applications, including plasma refueling, magnetized target fusion, injection of angular momentum into centrifugally confined mirrors, high energy density plasmas, and others. The approach uses symmetric injection of high density plasma into a coaxial electromagnetic accelerator having an annular gap geometry tailored to prevent formation of the blow-by instability. The injected plasma is generated by numerous (currently 32) radially oriented capillary discharges arranged uniformly around the circumference of the angled annular injection region of the accelerator. Magnetohydrodynamic modeling identified electrode profiles that can achieve the desired plasma jet parameters. The experimental hardware is described along with initial experimental results in which approximately 200 microg has been accelerated to 100 km/s in a half-scale prototype gun. Initial observations of 64 merging injector jets in a planar cylindrical testing array are presented. Density and velocity are presently limited by available peak current and injection sources. Steps to increase both the drive current and the injected plasma mass are described for next generation experiments.

  7. A contoured gap coaxial plasma gun with injected plasma armature

    International Nuclear Information System (INIS)

    Witherspoon, F. Douglas; Case, Andrew; Messer, Sarah J.; Bomgardner, Richard II; Phillips, Michael W.; Brockington, Samuel; Elton, Raymond

    2009-01-01

    A new coaxial plasma gun is described. The long term objective is to accelerate 100-200 μg of plasma with density above 10 17 cm -3 to greater than 200 km/s with a Mach number above 10. Such high velocity dense plasma jets have a number of potential fusion applications, including plasma refueling, magnetized target fusion, injection of angular momentum into centrifugally confined mirrors, high energy density plasmas, and others. The approach uses symmetric injection of high density plasma into a coaxial electromagnetic accelerator having an annular gap geometry tailored to prevent formation of the blow-by instability. The injected plasma is generated by numerous (currently 32) radially oriented capillary discharges arranged uniformly around the circumference of the angled annular injection region of the accelerator. Magnetohydrodynamic modeling identified electrode profiles that can achieve the desired plasma jet parameters. The experimental hardware is described along with initial experimental results in which approximately 200 μg has been accelerated to 100 km/s in a half-scale prototype gun. Initial observations of 64 merging injector jets in a planar cylindrical testing array are presented. Density and velocity are presently limited by available peak current and injection sources. Steps to increase both the drive current and the injected plasma mass are described for next generation experiments.

  8. Strontium isotopes test long-term zonal isolation of injected and Marcellus formation water after hydraulic fracturing.

    Science.gov (United States)

    Kohl, Courtney A Kolesar; Capo, Rosemary C; Stewart, Brian W; Wall, Andrew J; Schroeder, Karl T; Hammack, Richard W; Guthrie, George D

    2014-08-19

    One concern regarding unconventional hydrocarbon production from organic-rich shale is that hydraulic fracture stimulation could create pathways that allow injected fluids and deep brines from the target formation or adjacent units to migrate upward into shallow drinking water aquifers. This study presents Sr isotope and geochemical data from a well-constrained site in Greene County, Pennsylvania, in which samples were collected before and after hydraulic fracturing of the Middle Devonian Marcellus Shale. Results spanning a 15-month period indicated no significant migration of Marcellus-derived fluids into Upper Devonian/Lower Mississippian units located 900-1200 m above the lateral Marcellus boreholes or into groundwater sampled at a spring near the site. Monitoring the Sr isotope ratio of water from legacy oil and gas wells or drinking water wells can provide a sensitive early warning of upward brine migration for many years after well stimulation.

  9. A fast alternative to core plug tests for optimising injection water salinity for EOR

    DEFF Research Database (Denmark)

    Hassenkam, Tue; Andersson, Martin Peter; Hilner, Emelie Kristin Margareta

    2014-01-01

    of the clays which would lead to permanent reservoir damage but evidence of effectiveness at moderate salinity would offer the opportunity to dispose of produced water. The goal is to define boundary conditions so injection water salinity is high enough to prevent reservoir damage and low enough to induce...... the low salinity effect while keeping costs and operational requirements at a minimum. Traditional core plug testing for optimising conditions has some limitations. Each test requires a fresh sample, core testing requires sophisticated and expensive equipment, and reliable core test data requires several...... experiments can be done relatively quickly on very little material, it gives the possibility of testing salinity response on samples from throughout a reservoir and for gathering statistics. Our approach provides a range of data that can be used to screen core plug testing conditions and to provide extra data...

  10. Compact toroid injection into C-2U

    Science.gov (United States)

    Roche, Thomas; Gota, H.; Garate, E.; Asai, T.; Matsumoto, T.; Sekiguchi, J.; Putvinski, S.; Allfrey, I.; Beall, M.; Cordero, M.; Granstedt, E.; Kinley, J.; Morehouse, M.; Sheftman, D.; Valentine, T.; Waggoner, W.; the TAE Team

    2015-11-01

    Sustainment of an advanced neutral beam-driven FRC for a period in excess of 5 ms is the primary goal of the C-2U machine at Tri Alpha Energy. In addition, a criteria for long-term global sustainment of any magnetically confined fusion reactor is particle refueling. To this end, a magnetized coaxial plasma-gun has been developed. Compact toroids (CT) are to be injected perpendicular to the axial magnetic field of C-2U. To simulate this environment, an experimental test-stand has been constructed. A transverse magnetic field of B ~ 1 kG is established (comparable to the C-2U axial field) and CTs are fired across it. As a minimal requirement, the CT must have energy density greater than that of the magnetic field it is to penetrate, i.e., 1/2 ρv2 >=B2 / 2μ0 . This criteria is easily met and indeed the CTs traverse the test-stand field. A preliminary experiment on C-2U shows the CT also capable of penetrating into FRC plasmas and refueling is observed resulting in a 20 - 30% increase in total particle number per single-pulsed CT injection. Results from test-stand and C-2U experiments will be presented.

  11. Trapping of gun-injected plasma by a tokamak

    International Nuclear Information System (INIS)

    Leonard, A.W.; Dexter, R.N.; Sprott, J.C.

    1986-01-01

    It is shown that a plasma produced by a Marshall gun can be injected into and trapped by a tokamak plasma. Gun injection raises the line-averaged density and peaks the density profile. Trapping of the gun-injected plasma is explainable in terms of a depolarization current mechanism

  12. Assessment of the Efficiency of Consolidation Treatment through Injections of Expanding Resins by Geotechnical Tests and 3D Electrical Resistivity Tomography

    Science.gov (United States)

    2015-01-01

    The design and execution of consolidation treatment of settled foundations by means of injection of polyurethane expanding resins require a proper investigation of the state of the foundation soil, in order to better identify anomalies responsible for the instability. To monitor the injection process, a procedure has been developed, which involves, in combination with traditional geotechnical tests, the application of a noninvasive, geophysical technique based on the electrical resistivity, which is strongly sensitive to presence of water or voids. Three-dimensional electrical resistivity tomography is a useful tool to produce effective 3D images of the foundation soils before, during, and after the injections. The achieved information allows designing the consolidation scheme and monitoring its effects on the treated volumes in real time. To better understand the complex processes induced by the treatment and to learn how variations of resistivity accompany increase of stiffness, an experiment was carried out in a full-scale test site. Injections of polyurethane expanding resin were performed as in real worksite conditions. Results confirm that the experimented approach by means of 3D resistivity imaging allows a reliable procedure of consolidation, and geotechnical tests demonstrate the increase of mechanical stiffness. PMID:26167521

  13. Assessment of MARS for downcomer multi-dimensional thermal hydraulics during LBLOCA reflood using KAERI air-water direct vessel injection tests

    Energy Technology Data Exchange (ETDEWEB)

    Won-Jae, Lee; Kwi-Seok, Ha; Chul-Hwa, Song [Korea Atomic Energy Research Inst., Daejeon (Korea, Republic of)

    2001-07-01

    The MARS code has been assessed for the downcomer multi-dimensional thermal hydraulics during a large break loss-of-coolant accident (LBLOCA) reflood of Korean Next Generation Reactor (KNGR) that adopted an upper direct vessel injection (DVI) design. Direct DVI bypass and downcomer level sweep-out tests carried out at 1/50-scale air-water DVI test facility are simulated to examine the capability of MARS. Test conditions are selected such that they represent typical reflood conditions of KNGR, that is, DVI injection velocities of 1.0 {approx} 1.6 m/sec and air injection velocities of 18.0 {approx} 35.0 m/sec, for single and double DVI configurations. MARS calculation is first adjusted to the experimental DVI film distribution that largely affects air-water interaction in a scaled-down downcomer, then, the code is assessed for the selected test matrix. With some improvements of MARS thermal-hydraulic (T/H) models, it has been demonstrated that the MARS code is capable of simulating the direct DVI bypass and downcomer level sweep-out as well as the multi-dimensional thermal hydraulics in downcomer, where condensation effect is excluded. (authors)

  14. Development of devices for self-injection: using tribological analysis to optimize injection force

    Directory of Open Access Journals (Sweden)

    Lange J

    2016-05-01

    Full Text Available Jakob Lange, Leos Urbanek, Stefan BurrenYpsomed Delivery Systems, Ypsomed AG, Burgdorf, Switzerland Abstract: This article describes the use of analytical models and physical measurements to characterize and optimize the tribological behavior of pen injectors for self-administration of biopharmaceuticals. One of the main performance attributes of this kind of device is its efficiency in transmitting the external force applied by the user on to the cartridge inside the pen in order to effectuate an injection. This injection force characteristic is heavily influenced by the frictional properties of the polymeric materials employed in the mechanism. Standard friction tests are available for characterizing candidate materials, but they use geometries and conditions far removed from the actual situation inside a pen injector and thus do not always generate relevant data. A new test procedure, allowing the direct measurement of the coefficient of friction between two key parts of a pen injector mechanism using real parts under simulated use conditions, is presented. In addition to the absolute level of friction, the test method provides information on expected evolution of friction over lifetime as well as on expected consistency between individual devices. Paired with an analytical model of the pen mechanism, the frictional data allow the expected overall injection system force efficiency to be estimated. The test method and analytical model are applied to a range of polymer combinations with different kinds of lubrication. It is found that material combinations used without lubrication generally have unsatisfactory performance, that the use of silicone-based internal lubricating additives improves performance, and that the best results can be achieved with external silicone-based lubricants. Polytetrafluoroethylene-based internal lubrication and external lubrication are also evaluated but found to provide only limited benefits unless used in

  15. Air-injection field tests to determine the effect of a heat cycle on the permeability of welded tuff

    International Nuclear Information System (INIS)

    Lee, K.H.; Ueng, Tzou-Shin.

    1991-01-01

    As part of a series of prototype tests conducted in preparation for site characterization of the potential nuclear-waste repository site at Yucca Mountain, Nevada, air-injection tests were conducted in the welded tuffs in G-Tunnel at the Nevada Test Site. The objectives were to characterize the permeability of the highly fractured tuff around a horizontal heater emplacement borehole, and to determine the effect of a heating and cooling cycle on the rock-mass permeability. Air was injected into packed-off intervals along the heater borehole. The bulk permeability of the rock adjacent to the test interval and the aperture of fractures intersecting the interval were computed from the air-flow rate, temperature, and pressure at steady state. The bulk permeability of intervals along with borehole varied from a minimum of 0.08 D to a maximum of over 144 D and the equivalent parallel-plate apertures of fractures intersecting the borehole varied from 70 to 589 μm. Higher permeabilities seemed to correlate spatially with the mapped fractures. The rock was then heated for a period of 6.5 months with an electrical-resistive heater installed in the borehole. After heating, the rock was allowed to cool down to the ambient temperature. The highest borehole wall temperature measured was 242 degree C. Air injection tests were repeated following the heating and cooling cycle, and the results showed significant increases in bulk permeability ranging from 10 to 1830% along the borehole. 8 ref., 6 figs., 3 tabs

  16. Effects of injection timing on the engine performance and exhaust emissions of a dual-fuel diesel engine

    International Nuclear Information System (INIS)

    Sayin, Cenk; Canakci, Mustafa

    2009-01-01

    In this study, influence of injection timing on the engine performance and exhaust emissions of a naturally aspirated, single cylinder diesel engine has been experimentally investigated when using ethanol blended diesel fuel from 0% to 15% with an increment of 5%. The engine load was selected as 15 and 30 Nm. The tests were conducted at five different injection timings (21 deg., 24 deg., 27 deg., 30 deg. and 33 deg. CA BTDC) by changing the thickness of advance shim. The experimental test results showed that BSFC and emissions of NO x and CO 2 increased as BTE and emissions of CO and HC decreased with increasing amount of ethanol in the fuel mixture. When compared to the results of original injection timing (27 deg. CA BTDC), NO x and CO 2 emissions increased, and unburned HC and CO emissions decreased for the retarded injection timings (21 deg. and 24 deg. CA BTDC) at the all test conditions. On the other side, with the advanced injection timings (30 deg. and 33 deg. CA BTDC), decreasing HC and CO emissions diminished, and NO x and CO 2 emissions boosted. In terms of BSFC and BTE, retarded and advanced injection timings compared to the original injection timing in the all fuel blends gave negative results for all engine speeds and loads

  17. Effects of injection timing on the engine performance and exhaust emissions of a dual-fuel diesel engine

    Energy Technology Data Exchange (ETDEWEB)

    Sayin, Cenk [Department of Mechanical Education, Marmara University, 34722 Istanbul (Turkey); Canakci, Mustafa [Department of Mechanical Education, Kocaeli University, 41380 Izmit (Turkey); Alternative Fuels R and D Center, Kocaeli University, 41040 Izmit (Turkey)

    2009-01-15

    In this study, influence of injection timing on the engine performance and exhaust emissions of a naturally aspirated, single cylinder diesel engine has been experimentally investigated when using ethanol blended diesel fuel from 0% to 15% with an increment of 5%. The engine load was selected as 15 and 30 Nm. The tests were conducted at five different injection timings (21 , 24 , 27 , 30 and 33 CA BTDC) by changing the thickness of advance shim. The experimental test results showed that BSFC and emissions of NO{sub x} and CO{sub 2} increased as BTE and emissions of CO and HC decreased with increasing amount of ethanol in the fuel mixture. When compared to the results of original injection timing (27 CA BTDC), NO{sub x} and CO{sub 2} emissions increased, and unburned HC and CO emissions decreased for the retarded injection timings (21 and 24 CA BTDC) at the all test conditions. On the other side, with the advanced injection timings (30 and 33 CA BTDC), decreasing HC and CO emissions diminished, and NO{sub x} and CO{sub 2} emissions boosted. In terms of BSFC and BTE, retarded and advanced injection timings compared to the original injection timing in the all fuel blends gave negative results for all engine speeds and loads. (author)

  18. Effects of single injection of local anesthetic agents on intervertebral disc degeneration: ex vivo and long-term in vivo experimental study.

    Directory of Open Access Journals (Sweden)

    Koji Iwasaki

    Full Text Available Analgesic discography (discoblock can be used to diagnose or treat discogenic low back pain by injecting a small amount of local anesthetics. However, recent in vitro studies have revealed cytotoxic effects of local anesthetics on intervertebral disc (IVD cells. Here we aimed to investigate the deteriorative effects of lidocaine and bupivacaine on rabbit IVDs using an organotypic culture model and an in vivo long-term follow-up model.For the organotypic culture model, rabbit IVDs were harvested and cultured for 3 or 7 days after intradiscal injection of local anesthetics (1% lidocaine or 0.5% bupivacaine. Nucleus pulposus (NP cell death was measured using confocal microscopy. Histological and TUNEL assays were performed. For in vivo study, each local anesthetic was injected into rabbit lumbar IVDs under a fluoroscope. Six or 12 months after the injection, each IVD was prepared for magnetic resonance imaging (MRI and histological analysis.In the organotypic culture model, both anesthetic agents induced time-dependent NP cell death; when compared with injected saline solution, significant effects were detected within 7 days. Compared with the saline group, TUNEL-positive NP cells were significantly increased in the bupivacaine group. In the in vivo study, MRI analysis did not show any significant difference. Histological analysis revealed that IVD degeneration occurred to a significantly level in the saline- and local anesthetics-injected groups compared with the untreated control or puncture-only groups. However, there was no significant difference between the saline and anesthetic agents groups.In the in vivo model using healthy IVDs, there was no strong evidence to suggest that discoblock with local anesthetics has the potential of inducing IVD degeneration other than the initial mechanical damage of the pressurized injection. Further studies should be performed to investigate the deteriorative effects of the local injection of analgesic agents

  19. Medium-term and long-term outcomes of interventions for primary psoas tendinopathy.

    Science.gov (United States)

    Garala, Kanai; Prasad, Vishnu; Jeyapalan, Kanagaratnam; Power, Richard A

    2014-05-01

    To assess medium- and long-term outcomes of psoas tendinopathy to psoas tenotomy and image-guided steroid injections. This is a 14-year retrospective case-control study to identify the efficacy of psoas tenotomy and image-guided steroid injections. This study was undertaken in a secondary care setting. Patients with confirmed psoas tendinopathy were followed up by postal questionnaire, which included a nonarthritic hip score (NAHS) and a study patient satisfaction questionnaire. Patients underwent image-guided steroid injections. Depending on the analgesic or symptomatic relief, some patients proceeded to psoas tenotomy. Response to steroid injection. Pain relief and symptomatic relief after the surgery. Twenty-three patients were reviewed with a 70% follow-up over a time of 49 months for surgery (range, 13-144 months) and 77 months for injection (range, 14-160 months). Eight patients had a lasting response to injection and required no further intervention, and 15 patients proceeded to psoas tenotomy using a medial Ludloff approach. The average NAHS scores after the surgery and injection were 66.15 and 76.08, respectively. Ten patients reported pain relief after their tenotomy, and 5 patients reported no change in pain. All 8 patients, who only underwent injection, reported lasting pain relief. Local steroid injections can provide long-term relief for patients presenting with psoas tendinopathy. For those patients with only temporary relief from injection, psoas tenotomy can provide good long-term pain relief.

  20. Sensation of Cold during the Ice Water Test Corresponds to the Perception of Pain during Botulinum Toxin Bladder Wall Injections.

    Science.gov (United States)

    Reitz, André; Hüsch, Tanja; Doggweiler, Regula; Buse, Stephan; Haferkamp, Axel

    2018-01-01

    To investigate the association of bladder cold sensation (BCS) during the ice water test (IWT) and pain perception when botulinum toxin injections (BTI) are administered into the bladder wall. In 86 patients with idiopathic overactive bladder, the BCS during the IWT was investigated. Patients were divided into 2 groups: with and without BCS. During subsequent administration of BTI, the number of perceived and painful injections as well as the pain levels on a 0-100 pain scale were compared in both groups using Student t test. Thirty-five patients reported a BCS, while 51 did not. After 10 BTI, the mean number of perceived injections was 7.9 in patients with and 2.4 in patients without BCS (p sensation (p perceptions of cold and pain in the urinary bladder may use similar receptors and neuronal pathways. © 2018 S. Karger AG, Basel.

  1. FURNACE INJECTION OF ALKALINE SORBENTS FOR SULFURIC ACID CONTROL; SEMIANNUAL

    International Nuclear Information System (INIS)

    Gary M. Blythe

    2002-01-01

    This document summarizes progress on Cooperative Agreement DE-FC26-99FT40718, Furnace Injection of Alkaline Sorbents for Sulfuric Acid Control, during the time period October 1, 2001 through March 31, 2002. The objective of this project is to demonstrate the use of alkaline reagents injected into the furnace of coal-fired boilers as a means of controlling sulfuric acid emissions. The coincident removal of hydrochloric acid and hydrofluoric acid is also being determined, as is the removal of arsenic, a known poison for NO(sub X) selective catalytic reduction (SCR) catalysts. EPRI, the Tennessee Valley Authority (TVA), FirstEnergy Corporation, American Electric Power (AEP) and the Dravo Lime Company are project co-funders. URS Corporation is the prime contractor. This is the fifth reporting period for the subject Cooperative Agreement. During the previous (fourth) period, two long-term sorbent injection tests were conducted, one on Unit 3 at FirstEnergy's Bruce Mansfield Plant (BMP) and one on Unit 1 at AEP's Gavin Plant. Those tests determined the effectiveness of injecting alkaline slurries into the upper furnace of the boiler as a means of controlling sulfuric acid emissions from these units. The alkaline slurries tested included commercially available magnesium hydroxide slurry (Gavin Plant) and a byproduct magnesium hydroxide slurry (at both Gavin and BMP). The tests showed that injecting either the commercial or the byproduct magnesium hydroxide slurry could achieve up to 70-75% overall sulfuric acid removal. At BMP, the overall removal was limited by the need to maintain acceptable electrostatic precipitator (ESP) particulate control performance. At Gavin Plant, the overall sulfuric acid removal was limited because the furnace injected sorbent was less effective at removing SO(sub 3) formed across the SCR system installed on the unit for NO(sub X) control than at removing SO(sub 3) formed in the furnace. The SO(sub 3) removal results were presented in the

  2. Experiences with urine drug testing by police among people who inject drugs in Bangkok, Thailand.

    Science.gov (United States)

    Hayashi, Kanna; Ti, Lianping; Buxton, Jane A; Kaplan, Karyn; Suwannawong, Paisan; Wood, Evan; Kerr, Thomas

    2014-03-01

    Thailand has relied on drug law enforcement in an effort to curb illicit drug use. While anecdotal reports suggest that Thai police frequently use urine toxicology to identify drug users, little is known about the prevalence or impacts of this practice among people who inject drugs (IDU). Therefore, we sought to examine experiences with urine drug testing by police among IDU in Bangkok. Data were derived from a community-recruited sample of IDU in Bangkok participating in the Mitsampan Community Research Project between July and October 2011. We assessed the prevalence and correlates of being subjected to urine toxicology testing by police using multivariate Poisson regression. In total, 438 IDU participated in this study, with 293 (66.9%) participants reporting having been tested for illicit drugs by police. In multivariate analyses, reports of drug testing by police were independently and positively associated with younger age (adjusted prevalence ratio [APR]: 1.28), a history of methamphetamine injection (APR: 1.22), a history of incarceration (APR: 1.21), having been in compulsory drug detention (APR: 1.43), avoiding healthcare (APR: 1.15), and HIV seropositivity (APR: 1.19), and negatively associated with access to voluntary drug treatment (APR: 0.82) (all p<0.05). A high proportion of IDU in Bangkok were subjected to drug testing by police. Young people and methamphetamine injectors were more likely to have been tested. The findings indicate that drug testing by police is associated with the compulsory drug detention system and may be interfering with IDU's access to healthcare and voluntary drug treatment. These findings raise concern about the widespread practice of drug testing by police and its associated impacts. Copyright © 2013 Elsevier B.V. All rights reserved.

  3. Effect of injection timing on the exhaust emissions of a diesel engine using diesel-methanol blends

    Energy Technology Data Exchange (ETDEWEB)

    Sayin, Cenk; Gumus, Metin [Department of Mechanical Education, Marmara University, 34722 Istanbul (Turkey); Ilhan, Murat [Raytheon Training International GmbH, GM Academy, 34843 Istanbul (Turkey); Canakci, Mustafa [Department of Mechanical Education, Kocaeli University, 41380 Kocaeli (Turkey)]|[Alternative Fuels R and D Center, Kocaeli University, 41040 Kocaeli (Turkey)

    2009-05-15

    Environmental concerns and limited resource of petroleum fuels have caused interests in the development of alternative fuels for internal combustion (IC) engines. For diesel engines, alcohols are receiving increasing attention because they are oxygenated and renewable fuels. Therefore, in this study, the effect of injection timing on the exhaust emissions of a single cylinder, naturally aspirated, four-stroke, direct injection diesel engine has been experimentally investigated by using methanol-blended diesel fuel from 0% to 15% with an increment of 5%. The tests were conducted for three different injection timings (15 , 20 and 25 CA BTDC) at four different engine loads (5 Nm, 10 Nm, 15 Nm, 20 Nm) at 2200 rpm. The experimental test results showed that Bsfc, NO{sub x} and CO{sub 2} emissions increased as BTE, smoke opacity, CO and UHC emissions decreased with increasing amount of methanol in the fuel mixture. When compared the results to those of original injection timing, NO{sub x} and CO{sub 2} emissions decreased, smoke opacity, UHC and CO emissions increased for the retarded injection timing (15 CA BTDC). On the other hand, with the advanced injection timing (25 CA BTDC), decreasing smoke opacity, UHC and CO emissions diminished, and NO{sub x} and CO{sub 2} emissions boosted at all test conditions. In terms of Bsfc and BTE, retarded and advanced injection timings gave negative results for all fuel blends in all engine loads. (author)

  4. Trapping of gun-injected plasma by a tokamak

    International Nuclear Information System (INIS)

    Leonard, A.W.; Dexter, R.N.; Sprott, J.C.

    1987-01-01

    It has been seen that a plasma produced by a Marshall gun can be injected into and trapped by a tokamak plasma. This trapping of a gun-injected plasma is explained in terms of a depolarization current mechanism. A model is developed that describes the slowing of a plasma beam crossing into the magnetic field of a tokamak. The slowing down time is shown to go as tau/sub s/proportionalT/sup 3/2//sub e/L 2 /n/sub b/α 2 0 , where n/sub b/ and T/sub e/ are the density and temperature of the plasma beam and α 0 /L is the pitch of the field lines per unit length in the direction in which the beam is traveling. Experimental tests of this model are consistent with the scaling predictions

  5. Comparison of MELCOR modeling techniques and effects of vessel water injection on a low-pressure, short-term, station blackout at the Grand Gulf Nuclear Station

    International Nuclear Information System (INIS)

    Carbajo, J.J.

    1995-06-01

    A fully qualified, best-estimate MELCOR deck has been prepared for the Grand Gulf Nuclear Station and has been run using MELCOR 1.8.3 (1.8 PN) for a low-pressure, short-term, station blackout severe accident. The same severe accident sequence has been run with the same MELCOR version for the same plant using the deck prepared during the NUREG-1150 study. A third run was also completed with the best-estimate deck but without the Lower Plenum Debris Bed (BH) Package to model the lower plenum. The results from the three runs have been compared, and substantial differences have been found. The timing of important events is shorter, and the calculated source terms are in most cases larger for the NUREG-1150 deck results. However, some of the source terms calculated by the NUREG-1150 deck are not conservative when compared to the best-estimate deck results. These results identified some deficiencies in the NUREG-1150 model of the Grand Gulf Nuclear Station. Injection recovery sequences have also been simulated by injecting water into the vessel after core relocation started. This marks the first use of the new BH Package of MELCOR to investigate the effects of water addition to a lower plenum debris bed. The calculated results indicate that vessel failure can be prevented by injecting water at a sufficiently early stage. No pressure spikes in the vessel were predicted during the water injection. The MELCOR code has proven to be a useful tool for severe accident management strategies

  6. A contoured gap coaxial plasma gun with injected plasma armature

    Energy Technology Data Exchange (ETDEWEB)

    Witherspoon, F. Douglas; Case, Andrew; Messer, Sarah J.; Bomgardner, Richard II; Phillips, Michael W.; Brockington, Samuel; Elton, Raymond [HyperV Technologies Corp., Chantilly, Virginia 20151 (United States)

    2009-08-15

    A new coaxial plasma gun is described. The long term objective is to accelerate 100-200 {mu}g of plasma with density above 10{sup 17} cm{sup -3} to greater than 200 km/s with a Mach number above 10. Such high velocity dense plasma jets have a number of potential fusion applications, including plasma refueling, magnetized target fusion, injection of angular momentum into centrifugally confined mirrors, high energy density plasmas, and others. The approach uses symmetric injection of high density plasma into a coaxial electromagnetic accelerator having an annular gap geometry tailored to prevent formation of the blow-by instability. The injected plasma is generated by numerous (currently 32) radially oriented capillary discharges arranged uniformly around the circumference of the angled annular injection region of the accelerator. Magnetohydrodynamic modeling identified electrode profiles that can achieve the desired plasma jet parameters. The experimental hardware is described along with initial experimental results in which approximately 200 {mu}g has been accelerated to 100 km/s in a half-scale prototype gun. Initial observations of 64 merging injector jets in a planar cylindrical testing array are presented. Density and velocity are presently limited by available peak current and injection sources. Steps to increase both the drive current and the injected plasma mass are described for next generation experiments.

  7. An experimental study of injection and spray characteristics of diesel and gasoline blends on a common rail injection system

    International Nuclear Information System (INIS)

    Han, Dong; Wang, Chunhai; Duan, Yaozong; Tian, Zhisong; Huang, Zhen

    2014-01-01

    The injection and spray characteristics of diesel and gasoline blends are investigated on a common rail injection system. The injection rate, fuel spray evolution process (tip penetration distance, spray cone angle, projected spray area and relative brightness intensity contour) and microscopic droplet features are analyzed. The results show that diesel and gasoline blends have higher volumetric injection rates, earlier starts of injection and shorter injection delays, but little variances are observed in the mass injection rates for different test fuels. Increased gasoline proportion in the test blends causes slightly decreased spray tip penetration distance but increased spray cone angle. Also, more smaller-size droplets are observed in the fuel jet of the diesel and gasoline blends, indicating that the spray breakup and atomization processes are promoted. - Highlights: • Injection rate and spray characteristics of diesel and gasoline blends are studied. • Diesel and gasoline blends have higher volumetric injection rates. • Earlier starts of injection are found when using diesel and gasoline blends. • Diesel and gasoline blends produce shorter spray penetration but higher cone angle. • The number of small droplets increases in the spray of diesel and gasoline blends

  8. Pressure and pressure derivative analysis for injection tests with variable temperature without type-curve matching

    International Nuclear Information System (INIS)

    Escobar, Freddy Humberto; Martinez, Javier Andres; Montealegre Matilde

    2008-01-01

    The analysis of injection tests under nonisothermic conditions is important for the accurate estimation of the reservoir permeability and the well's skin factor; since previously an isothermical system was assumed without taking into account a moving temperature front which expands with time plus the consequent changes in both viscosity and mobility between the cold and the hot zone of the reservoir which leads to unreliable estimation of the reservoir and well parameters. To construct the solution an analytical approach presented by Boughrara and Peres (2007) was used. That solution was initially introduced for the calculation of the injection pressure in an isothermic system. It was later modified by Boughrara and Reynolds (2007) to consider a system with variable temperature in vertical wells. In this work, the pressure response was obtained by numerical solution of the anisothermical model using the Gauss Quadrature method to solve the integrals, and assuming that both injection and reservoir temperatures were kept constant during the injection process and the water saturation is uniform throughout the reservoir. For interpretation purposes, a technique based upon the unique features of the pressure and pressure derivative curves were used without employing type-curve matching (TDS technique). The formulation was verified by its application to field and synthetic examples. As expected, increasing reservoir temperature causes a decrement in the mobility ratio, then estimation of reservoir permeability is some less accurate from the second radial flow, especially, as the mobility ratio increases

  9. Quantification of a maximum injection volume of CO2 to avert geomechanical perturbations using a compositional fluid flow reservoir simulator

    Science.gov (United States)

    Jung, Hojung; Singh, Gurpreet; Espinoza, D. Nicolas; Wheeler, Mary F.

    2018-02-01

    Subsurface CO2 injection and storage alters formation pressure. Changes of pore pressure may result in fault reactivation and hydraulic fracturing if the pressure exceeds the corresponding thresholds. Most simulation models predict such thresholds utilizing relatively homogeneous reservoir rock models and do not account for CO2 dissolution in the brine phase to calculate pore pressure evolution. This study presents an estimation of reservoir capacity in terms of allowable injection volume and rate utilizing the Frio CO2 injection site in the coast of the Gulf of Mexico as a case study. The work includes laboratory core testing, well-logging data analyses, and reservoir numerical simulation. We built a fine-scale reservoir model of the Frio pilot test in our in-house reservoir simulator IPARS (Integrated Parallel Accurate Reservoir Simulator). We first performed history matching of the pressure transient data of the Frio pilot test, and then used this history-matched reservoir model to investigate the effect of the CO2 dissolution into brine and predict the implications of larger CO2 injection volumes. Our simulation results -including CO2 dissolution- exhibited 33% lower pressure build-up relative to the simulation excluding dissolution. Capillary heterogeneity helps spread the CO2 plume and facilitate early breakthrough. Formation expansivity helps alleviate pore pressure build-up. Simulation results suggest that the injection schedule adopted during the actual pilot test very likely did not affect the mechanical integrity of the storage complex. Fault reactivation requires injection volumes of at least about sixty times larger than the actual injected volume at the same injection rate. Hydraulic fracturing necessitates much larger injection rates than the ones used in the Frio pilot test. Tested rock samples exhibit ductile deformation at in-situ effective stresses. Hence, we do not expect an increase of fault permeability in the Frio sand even in the presence of

  10. Scaleup tests and supporting research for the development of duct injection technology: Topical report No. 3, Task 3.2: Scale-up testing; Topical report No. 4, Task 3.3: Advanced configurations; Topical report No. 5, Task 3.4: Process controls; Topical report No. 6, Task 3.5: Failure modes; Task 3.6: Waste characterization, Duct Injection Test Facility, Muskingum River Power Plant, Beverly, Ohio

    Energy Technology Data Exchange (ETDEWEB)

    Felix, L.G.; Gooch, J.P.; Merritt, R.L. [Southern Research Inst., Birmingham, AL (United States); Klett, M.G.; Demian, A.G.; Hunt, J.E. [Gilbert/Commonwealth, Inc., Reading, PA (United States)

    1992-08-01

    This document is the third interim report on tests that were conducted at the Duct Injection Test Facility (DITF) operated for the Department of Energy at Unit 5 of the Ohio Power Company`s Muskingum River station in Beverly, Ohio. At the DITF dry calcium hydroxide (Ca(OH)2), an aqueous slurry of Ca(OH){sub 2} (prepared by slaking quicklime), or a mixture of one of these sorbents with waste ash from earlier tests was injected into a slipstream of flue gas from the Unit 5 boiler to achieve partial removal of SO{sub 2} in the flue gas. Up to 50,000 acfm of flue gas was taken from the inlet to the Unit 5 electrostatic precipitator (ESP) for these tests. Water was injected separately with the dry sorbent or as part of the slurry to cool the flue gas and increase the water vapor content of the flue gas. The addition of water, either as a separate spray or in the slurry makes the reaction between the sorbent and the SO{sub 2} more complete; the presumption is that water is effective in the liquid state when it can physically wet the sorbent particles, and not especially effective in the vapor state. Higher values of calcium utilization were obtained with slurry injection than with dry sorbent injection and humidification. Slurries made from reagent slaked lime, mixtures of reagent slaked lime and recycle ash, and from recycle ash alone were injected through the same nozzles used for humidification. The focus of most of these tests was on the constant addition of recycle ash to reduce the amount of slaked lime required for SO{sub 2} removal (for best economics). Testing was continued until the amount of Ca(OH){sub 2} in the recycle ash equaled that predicted for equilibrium Two test cases were evaluated: a low Ca/S ratio (1.0 reagent, 44{degrees}/F approach) for 50% SO{sub 2} removal and a high Ca/S ratio (1.7 reagent, 24{degrees}F approach) for 88% SO{sub 2} removal.

  11. Results of full scale dry injection tests at MSW-incinerators using a new active absorbent

    International Nuclear Information System (INIS)

    Felsvang, K.S.; Helvind, O.

    1991-01-01

    Worldwide incineration of municipal solid waste (MSW) has been utilized to reduce the volume of waste to be disposed of. Increasing environmental concerns over the potential air pollution impacts have led to emission limits for pollutants such as HCl, SO 2 , particulate, and more recently also for mercury and dioxins. For a certain size of incinerators, dry sorbent injection is the preferred technology for air pollution control. This paper describes the development of a new active sorbent, Scansorb, which is particularly suited for use in dry injection processes. The new sorbent is a lime based product with adjustable properties. Scansorb can be produced with a specific surface area of 30 to 100 m 2 /g. Pilot plant development work has shown that a considerable reduction in the absorbent quantity can be achieved when Scansorb is used instead of commercial hydrated lime. Full scale tests performed at four different MSW incinerators have confirmed the viability of the new active absorbent. The full scale tests have demonstrated that more than 50% SO 2 removal can be achieved with Scansorb at quantities much less than with commercial hydrated lime

  12. Flow-injection system for automated dissolution testing of isoniazid tablets with chemiluminescence detection.

    Science.gov (United States)

    Li, B; Zhang, Z; Liu, W

    2001-05-30

    A simple and sensitive flow-injection chemiluminescence (CL) system for automated dissolution testing is described and evaluated for monitoring of dissolution profiles of isoniazid tablets. The undissolved suspended particles in the dissolved solution were eliminated via on-line filter. The novel CL system of KIO(4)-isoniazid was also investigated. The sampling frequency of the system was 120 h(-1). The dissolution profiles of isoniazid fast-release tablets from three sources were determined, which demonstrates the stability, great sensitivity, large dynamic measuring range and robustness of the system.

  13. Inadvertent injection of succinylcholine as an epidural test dose

    Directory of Open Access Journals (Sweden)

    Chryssa Pourzitaki

    Full Text Available Abstract Background and objectives: Epidural action of neuromuscular blocking agents could be explained under the light of their physicochemical characteristics and epidural space properties. In the literature there are few cases of accidental neuromuscular agent's epidural administration, manifesting mainly with neuromuscular blockade institution or fasciculations. Case report: We report a case of accidental succinylcholine administration as an epidural test dose, in a female patient undergoing scheduled laparotomy, under combined general and epidural anesthesia. Approximately 2 min after the succinylcholine injection the patient complained for shortness of breath, while mild fasciculations appeared in her trunk and face, managed by immediate general anesthesia institution. With the exception of a relatively longer duration of neuromuscular blockade compared with intravenous administration, no neurological or cardiovascular sequelae or other symptoms of local or systemic toxicity were observed. Conclusions: Oral administration of diazepam seems to lessen the adverse effects from accidental epidural administration of succinylcholine. The meticulous and discriminative labeling of syringes, as well as keeping persistent cautions during all anesthesia procedures remains of crucial importance.

  14. High HIV Prevalence, Suboptimal HIV Testing, and Low Knowledge of HIV-Positive Serostatus Among Injection Drug Users in St. Petersburg, Russia

    Science.gov (United States)

    Toussova, Olga V.; Verevochkin, Sergei V.; Barbour, Russell; Heimer, Robert; Kozlov, Andrei P.

    2011-01-01

    The purpose of this analysis was to estimate human immunodeficiency virus (HIV) prevalence and testing patterns among injection drug users (IDUs) in St. Petersburg, Russia. HIV prevalence among 387 IDUs in the sample was 50%. Correlates of HIV-positive serostatus included unemployment, recent unsafe injections, and history/current sexually transmitted infection. Seventy-six percent had been HIV tested, but only 22% of those who did not report HIV-positive serostatus had been tested in the past 12 months and received their test result. Correlates of this measure included recent doctor visit and having been in prison or jail among men. Among the 193 HIV-infected participants, 36% were aware of their HIV-positive serostatus. HIV prevalence is high and continuing to increase in this population. Adequate coverage of HIV testing has not been achieved, resulting in poor knowledge of positive serostatus. Efforts are needed to better understand motivating and deterring factors for HIV testing in this setting. PMID:18843531

  15. Single-well injection-withdrawal tests (SWIW). Investigation of evaluation aspects under heterogeneous crystalline bedrock conditions

    International Nuclear Information System (INIS)

    Nordqvist, Rune; Gustafsson, Erik

    2004-08-01

    Single-well injection-withdrawal (SWIW) tracer tests have been identified by SKB as an investigation method for solute transport properties in the forthcoming site investigations. A previous report presents a literature study as well as scoping calculations for SWIW tests in homogeneous crystalline bedrock environments. The present report comprises further scoping calculations under assumptions of heterogeneous bedrock conditions. Simple but plausible homogeneous evaluation models are tested on simulated SWIW tests in hypothetical heterogeneous two-dimensional fractures. The results from this study indicate that heterogeneity may cause effects of flow irreversibility when background hydraulic gradients are significant and the tested section is located in a dominating flow path. This implies that such conditions make it more difficult to interpret results from SWIW tests of longer duration with sorbing and/or diffusing tracers. Sorption and diffusion processes may be best studied when SWIW tests are conducted in borehole sections with low natural flow rates

  16. Endoscopic Injection of Dextranomer/Hyaluronic Acid as First-Line Treatment in 851 Consecutive Children with High-Grade Vesicoureteral Reflux: Efficacy and Long-Term Results.

    Science.gov (United States)

    Friedmacher, Florian; Colhoun, Eric; Puri, Prem

    2018-03-15

    Endoscopic injection of dextranomer/hyaluronic is widely acknowledged as first-line treatment of lower grade vesicoureteral reflux. Our objective was to demonstrate its long-term efficacy and safety in eradicating high-grade reflux. Eight-hundred-fifty-one children (518 girls, 333 boys), median age 2.3 years (2 months-13.7 years), underwent endoscopic correction of high-grade vesicoureteral reflux using dextranomer/hyaluronic acid. Reflux was unilateral in 415 cases and bilateral in 436, comprising 1,287 refluxing units: grade IV in 1,153 (89.6%) and grade V in 134 (10.4%). 99m technetium-dimercaptosuccinic acid imaging identified renal scarring in 317 (37.3%) patients. Follow-up ultrasound and voiding cystourethrogram were performed 3 months post intervention and renal ultrasound annually thereafter. Median follow-up was 8.5 years (6 months-16 years). Overall resolution rate after the first endoscopic injection was 895/1,287 (69.5%): 70.4% in grade IV and 61.9% in grade V, respectively. Reflux resolved after a second injection in 259 (20.1%) and after a third in 133 (10.4%). Persistent reflux after initial treatment was significantly more common in infants reflux resolution, 43 (5.1%) children developed febrile urinary tract infections: 24 (55.8%) in the first, 15 (34.9%) in the second and 4 (9.3%) after ≥3 years. Of these, 6 had reflux recurrence and 8 demonstrated neocontralateral grade III reflux, which was successfully treated with single endoscopic injection of dextranomer/hyaluronic acid. Endoscopic injection of dextranomer/hyaluronic acid is an efficient and safe long-term treatment for grade IV and V vesicoureteral reflux, which can be easily repeated in cases of failure with a high subsequent resolution rate. Copyright © 2018 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  17. Combustion of jojoba methyl ester in an indirect injection diesel engine

    Energy Technology Data Exchange (ETDEWEB)

    Selim, M.Y.E. [United Arab Emirates University, Al-Ain (United Arab Emirates). Mechanical Engineering Dept.; Radwan, M.S.; Elfeky, S.M.S. [Helwan University, Cairo (Egypt). Mechanical Power Engineering Dept.

    2003-07-01

    An experimental investigation has been carried out to examine for the first time the performance and combustion noise of an indirect injection diesel engine running with new fuel derived from pure jojoba oil, jojoba methyl ester, and its blends with gas oil. A Ricardo E6 compression swirl diesel engine was fully instrumented for the measurement of combustion pressure and its rise rate and other operating parameters. Test parameters included the percentage of jojoba methyl ester in the blend, engine speed, load, injection timing and engine compression ratio. Results showed that the new fuel derived from jojoba is generally comparable and a good replacement to gas oil in diesel engine at most engine operating conditions, in terms of performance parameters and combustion noise produced. (author)

  18. Scaleup tests and supporting research for the development of duct injection technology: Topical report No. 3, Task 3. 2: Scale-up testing; Topical report No. 4, Task 3. 3: Advanced configurations; Topical report No. 5, Task 3. 4: Process controls; Topical report No. 6, Task 3. 5: Failure modes; Task 3. 6: Waste characterization, Duct Injection Test Facility, Muskingum River Power Plant, Beverly, Ohio

    Energy Technology Data Exchange (ETDEWEB)

    Felix, L.G.; Gooch, J.P.; Merritt, R.L. (Southern Research Inst., Birmingham, AL (United States)); Klett, M.G.; Demian, A.G.; Hunt, J.E. (Gilbert/Commonwealth, Inc., Reading, PA (United States))

    1992-08-01

    This document is the third interim report on tests that were conducted at the Duct Injection Test Facility (DITF) operated for the Department of Energy at Unit 5 of the Ohio Power Company's Muskingum River station in Beverly, Ohio. At the DITF dry calcium hydroxide (Ca(OH)2), an aqueous slurry of Ca(OH)[sub 2] (prepared by slaking quicklime), or a mixture of one of these sorbents with waste ash from earlier tests was injected into a slipstream of flue gas from the Unit 5 boiler to achieve partial removal of SO[sub 2] in the flue gas. Up to 50,000 acfm of flue gas was taken from the inlet to the Unit 5 electrostatic precipitator (ESP) for these tests. Water was injected separately with the dry sorbent or as part of the slurry to cool the flue gas and increase the water vapor content of the flue gas. The addition of water, either as a separate spray or in the slurry makes the reaction between the sorbent and the SO[sub 2] more complete; the presumption is that water is effective in the liquid state when it can physically wet the sorbent particles, and not especially effective in the vapor state. Higher values of calcium utilization were obtained with slurry injection than with dry sorbent injection and humidification. Slurries made from reagent slaked lime, mixtures of reagent slaked lime and recycle ash, and from recycle ash alone were injected through the same nozzles used for humidification. The focus of most of these tests was on the constant addition of recycle ash to reduce the amount of slaked lime required for SO[sub 2] removal (for best economics). Testing was continued until the amount of Ca(OH)[sub 2] in the recycle ash equaled that predicted for equilibrium Two test cases were evaluated: a low Ca/S ratio (1.0 reagent, 44[degrees]/F approach) for 50% SO[sub 2] removal and a high Ca/S ratio (1.7 reagent, 24[degrees]F approach) for 88% SO[sub 2] removal.

  19. Long-term correction of obesity and diabetes in genetically obese mice by a single intramuscular injection of recombinant adeno-associated virus encoding mouse leptin

    Science.gov (United States)

    Murphy, John E.; Zhou, Shangzhen; Giese, Klaus; Williams, Lewis T.; Escobedo, Jaime A.; Dwarki, Varavani J.

    1997-01-01

    The ob/ob mouse is genetically deficient in leptin and exhibits a phenotype that includes obesity and non-insulin-dependent diabetes melitus. This phenotype closely resembles the morbid obesity seen in humans. In this study, we demonstrate that a single intramuscular injection of a recombinant adeno-associated virus (AAV) vector encoding mouse leptin (rAAV-leptin) in ob/ob mice leads to prevention of obesity and diabetes. The treated animals show normalization of metabolic abnormalities including hyperglycemia, insulin resistance, impaired glucose tolerance, and lethargy. The effects of a single injection have lasted through the 6-month course of the study. At all time points measured the circulating levels of leptin in the serum were similar to age-matched control C57 mice. These results demonstrate that maintenance of normal levels of leptin (2–5 ng/ml) in the circulation can prevent both the onset of obesity and associated non-insulin-dependent diabetes. Thus a single injection of a rAAV vector expressing a therapeutic gene can lead to complete and long-term correction of a genetic disorder. Our study demonstrates the long-term correction of a disease caused by a genetic defect and proves the feasibility of using rAAV-based vectors for the treatment of chronic disorders like obesity. PMID:9391128

  20. The sensitivity testing of Wilms' tumors to cytostatic agents with an autoradiographic in vitro short-term test

    International Nuclear Information System (INIS)

    Willnow, U.

    1984-01-01

    Sensitivity of 15 Wilms' tumors in children was tested towards cytostatic agents in vitro by means of an autoradiographic short-term test. Sensitivity was measured as the magnitude of the inhibition of 3 H-thymidine or 3 H-uridine incorporation. The test was performed with Adriamycin, Actinomycin D, Daunomycin, Bleomycin, Cyclophosphamide, Ifosfamide, Trenimon, and Arabinosylcytosine. None of the tumors is resistant to all substances, they are responsive against 2 or more drugs. The most effective drugs tested are Adriamycin, Actinomycin D and Cyclophosphamide. The tumors show a marked individual sensitivity pattern. This behavior is explained mainly by the usually high proliferative activity of Wilms' tumors. The possibilities and limits of long-term and short-term methods for sensitivity testing are discussed critically. For the evaluation of the results of in vitro testing and in vivo effectiveness the close correlation should be considered between the type of cytostatic agent and proliferation kinetics of the tumor, cytostatic agent and effect on tumor metabolism as well as the effect of the cytostatics and the nucleic acid precursors used for the short-term test. Despite the methodological limitations preclinical testing should be preferred to unselected chemotherapy. (author)

  1. Advanced diesel electronic fuel injection and turbocharging

    Science.gov (United States)

    Beck, N. J.; Barkhimer, R. L.; Steinmeyer, D. C.; Kelly, J. E.

    1993-12-01

    The program investigated advanced diesel air charging and fuel injection systems to improve specific power, fuel economy, noise, exhaust emissions, and cold startability. The techniques explored included variable fuel injection rate shaping, variable injection timing, full-authority electronic engine control, turbo-compound cooling, regenerative air circulation as a cold start aid, and variable geometry turbocharging. A Servojet electronic fuel injection system was designed and manufactured for the Cummins VTA-903 engine. A special Servojet twin turbocharger exhaust system was also installed. A series of high speed combustion flame photos was taken using the single cylinder optical engine at Michigan Technological University. Various fuel injection rate shapes and nozzle configurations were evaluated. Single-cylinder bench tests were performed to evaluate regenerative inlet air heating techniques as an aid to cold starting. An exhaust-driven axial cooling air fan was manufactured and tested on the VTA-903 engine.

  2. Injective Labeled Oriented Trees are Aspherical

    OpenAIRE

    Harlander, Jens; Rosebrock, Stephan

    2012-01-01

    A labeled oriented tree is called injective if each generator occurs at most once as an edge label. We show that injective labeled oriented trees are aspherical. The proof relies on a new relative asphericity test based on a lemma of Stallings.

  3. Measurement of distribution coefficients using a radial injection dual-tracer test

    International Nuclear Information System (INIS)

    Pickens, J.F.; Jackson, R.E.; Inch, K.J.; Merritt, W.F.

    1981-01-01

    The dispersive and adsorptive properties of a sandy aquifer were evaluated by using a radial injection dual-tracer test with 131 I as the nonreactive tracer and 85 Sr as the reactive tracer. The tracer migration was monitored by using multilevel point-sampling devices located at various radial distances and depths. Nonequilibrium physical and chemical adsorption effects for 85 Sr were treated as a spreading or dispersion mechanism in the breakthrough curve analysis. The resulting effective dispersivity values for 85 Sr were typically a factor of 2 to 5 larger than those obtained for 131 I. The distribution coefficient (K/sub d//sup Sr/) values obtained from analysis of the breakthrough curves at three depths and two radial distances ranged from 2.6 to 4.5 ml/g. These compare favorably with values obtained by separation of fluids from solids in sediment cores, by batch experiments on core sediments and by analysis of a 25-year-old radioactive waste plume in another part of the same aquifer. Correlations of adsorbed 85 Sr radioactivity with grain size fractions demonstrated preferential adsorption to the coarsest fraction and to the finest fraction. The relative amounts of electrostatically and specifically adsorbed 85 Sr on the aquifer sediments were determined with desorption experiments on core sediments using selective chemical extractants. The withdrawal phase breakthrough curves for the well, obtained immediately following the injection phase, showed essentially full tracer recoveries for both 131 I and 85 Sr. Relatively slow desorption of 85 Sr provided further indication of the nonequilibrium nature of the adsorption-desorption phenomena

  4. Effect of injection timing on combustion and performance of a direct injection diesel engine running on Jatropha methyl ester

    Energy Technology Data Exchange (ETDEWEB)

    Jindal, S. [Mechanical Engineering Department, College of Technology & Engineering, Maharana Pratap University of Agriculture and Technology, Udaipur 313001 (India)

    2011-07-01

    The present study aims at evaluation of effect of injection timing on the combustion, performance and emissions of a small power diesel engine, commonly used for agriculture purpose, running on pure biodiesel, prepared from Jatropha (Jatropha curcas) vegetable oil. The effect of varying injection timing was evaluated in terms of thermal efficiency, specific fuel consumption, power and mean effective pressure, exhaust temperature, cylinder pressure, rate of pressure rise and the heat release rate. It was found that retarding the injection timing by 3 degrees enhances the thermal efficiency by about 8 percent.

  5. Long-term Results of Percutaneous Ethanol Injection for the Treatment of Hepatocellular Carcinoma in Korea

    International Nuclear Information System (INIS)

    Sung, Yon Mi; Choi, Don Gil; Lim, Hyo K.

    2006-01-01

    To evaluate the long-term follow-up results of percutaneous ethanol injection (PEI) for the treatment of hepatocellular carcinoma (HCC) in Korea. Sixty-eight nodular HCCs initially detected in 64 patients, were subjected to US-guided PEI as a first-line treatment. Long-term survival rates, local tumor progression rates, and complications were evaluated, as were the influences of tumor size and Child-Pugh class on these variables. No major complications occurred. The overall survival rates of the 64 patients at three and five years were 71% and 39%, and their cancer-free survival rates were 22% and 15%, respectively. The overall survival rate of patients with a small HCC (≤ 2 cm) was significantly higher (p = 0.014) than that of patients with a medium-sized HCC (≤ 2 cm). The overall survival rate of patients with Child- Pugh class A was significantly higher (p = 0.049) than that of patients with Child- Pugh class B. Of 59 cases with no residual tumor, local tumor progression was observed in ablation zones in 18, and this was not found to be significantly influenced by tumor size or Child-Pugh class. The results of our investigation of the long-term survival rates of PEI in HCC patients in Korea (a hepatitis B virus-endemic area) were consistent with those reported previously in hepatitis C endemic areas. Patients with a smaller tumor or a better liver function exhibited superior survival rates

  6. Providing Extrinsic Reward for Test Performance Undermines Long-Term Memory Acquisition

    Directory of Open Access Journals (Sweden)

    Christof eKuhbandner

    2016-02-01

    Full Text Available Based on numerous studies showing that testing studied material can improve long-term retention more than restudying the same material, it is often suggested that the number of tests in education should be increased to enhance knowledge acquisition. However, testing in real-life educational settings often entails a high degree of extrinsic motivation of learners due to the common practice of placing important consequences on the outcome of a test. Such an effect on the motivation of learners may undermine the beneficial effects of testing on long-term memory because it has been shown that extrinsic motivation can reduce the quality of learning. To examine this issue, participants learned foreign language vocabulary words, followed by an immediate test in which one third of the words were tested and one third restudied. To manipulate extrinsic motivation during immediate testing, participants received either monetary reward contingent on test performance or no reward. After one week, memory for all words was tested. In the immediate test, reward reduced correct recall and increased commission errors, indicating that reward reduced the number of items that can benefit from successful retrieval. The results in the delayed test revealed that reward additionally reduced the gain received from successful retrieval because memory for initially successfully retrieved words was lower in the reward condition. However, testing was still more effective than restudying under reward conditions because reward undermined long-term memory for concurrently restudied material as well. These findings indicate that providing performance-contingent reward in a test can undermine long-term knowledge acquisition.

  7. Providing Extrinsic Reward for Test Performance Undermines Long-Term Memory Acquisition.

    Science.gov (United States)

    Kuhbandner, Christof; Aslan, Alp; Emmerdinger, Kathrin; Murayama, Kou

    2016-01-01

    Based on numerous studies showing that testing studied material can improve long-term retention more than restudying the same material, it is often suggested that the number of tests in education should be increased to enhance knowledge acquisition. However, testing in real-life educational settings often entails a high degree of extrinsic motivation of learners due to the common practice of placing important consequences on the outcome of a test. Such an effect on the motivation of learners may undermine the beneficial effects of testing on long-term memory because it has been shown that extrinsic motivation can reduce the quality of learning. To examine this issue, participants learned foreign language vocabulary words, followed by an immediate test in which one-third of the words were tested and one-third restudied. To manipulate extrinsic motivation during immediate testing, participants received either monetary reward contingent on test performance or no reward. After 1 week, memory for all words was tested. In the immediate test, reward reduced correct recall and increased commission errors, indicating that reward reduced the number of items that can benefit from successful retrieval. The results in the delayed test revealed that reward additionally reduced the gain received from successful retrieval because memory for initially successfully retrieved words was lower in the reward condition. However, testing was still more effective than restudying under reward conditions because reward undermined long-term memory for concurrently restudied material as well. These findings indicate that providing performance-contingent reward in a test can undermine long-term knowledge acquisition.

  8. Injection grout for deep repositories - Low-pH cementitious grout for larger fractures. Field testing in Finland, Pilot tests

    International Nuclear Information System (INIS)

    Sievaeen, U.; Syrjaenen, P.; Ranta-aho, S.

    2005-10-01

    Posiva, SKB and NUMO have cooperated for developing a low pH injection grout for sealing of the deep repositories for spent nuclear fuel. A project 'Injection grout for deep repositories' was divided into four subprojects. The development of low pH cementitious grout for > 100 μm fractures was carried out in Finland. The development of non-cementitious low pH grout for < 100 μm fractures was carried out in Sweden. This report concerns the cementitious grout. Requirements for pH and penetration ability were set for the grouts to be developed. Besides these, the grouts were desired to fulfil certain targets set for viscosity, bleeding, shear strength, yield value, compressive strength and open time. Also durability, availability of the components and known history in practical engineering were given as requirements. The object of the work presented here was to test if the grout properties developed in laboratory can be met in field conditions. Only the most promising binder material combinations, which have fulfilled the main requirements in laboratory, were tested in field. Evaluations of environmental aspects are included in this report. In the pilot test 1, carried out in a multi-purpose tunnel in Helsinki, Portland cement-cilicasystem and blast furnace slag-based system were chosen to be tested. In field conditions, mixed with ordinary mixer, all grout properties achieved in laboratory, were not verified. Penetration ability was typically good, but fluidity and strength development were not satisfying. The main conclusion was that water to dry material ratio should be diminished. In order to get better rheological properties at the same time, superplastizicer was needed in further development of the mixes. Also accurate dosing and mixing seemed to be very important. Blast furnace slag - system was after this pilot test ruled out due to high leaching of sulphide from the product, not due to the bad technical properties. The development work continued with

  9. Effect of Intra Vitreal Injection of Bevacizumab on Intra-Occular Pressure

    International Nuclear Information System (INIS)

    Jaffar, S.; Tayyab, A.; Matin, Z. I.; Masrur, A.; Naqaish, R.

    2016-01-01

    Background: Bevacizumab has been in use as a therapeutic agent for macular oedema for several years. While its efficacy has been well documented, its use has been shown to cause a transient rise in the intra-ocular pressure. The aim of this study was to evaluate the long term effect of intra-vitreal injection of Bevacizumab on Intra-ocular pressure. Methods: One hundred eyes (n=100) of one hundred patients, requiring intra-vitreal injection of Bevacizumab for diabetic macular oedema were recruited from Shifa Foundation Community Health Centre (SFCHC) between January and December 2014. Patients of glaucoma, ocular hyper-tension, known allergy to Bevacizumab or had injections of Bevacizumab prior to the study were excluded. Intra-ocular pressure was measured using a Goldmann applanation tonometer, prior to, and at six and twelve months after the injection. The pre- and post- injection Intra-ocular pressure was entered into the database. Test of significance was applied to investigate whether there was a significant change in intra-ocular pressure after the injection. Results: The mean age of the patient was 56.97 years (±14.97). The mean intra-ocular pressure was 13.86 (±3.16) mmHg before injection, while post-injection mean Intra-Ocular pressure was 14.21 (±3.12) mmHg and 13.79 (±3.07) at six and twelve months respectively. Between baseline and six months there was a statistically significant difference in intra-ocular pressure (p=0.03), while no significant difference existed in the intra-ocular pressure between baseline and twelve months (p=0.92). Conclusion: Intra-vitreal injection of Bevacizumab is associated with a statically significant rise in intra-ocular pressure at six months, while no significant difference was seen at twelve months compared to baseline. (author)

  10. INJECTING EQUPMENT SHARING AND PERCEPTION OF HIV AND HEPATITIS RISK AMONG INJECTING DRUG USERS IN BUDAPEST

    Science.gov (United States)

    Gyarmathy, V. Anna; Neaigus, Alan; Ujhelyi, Eszter

    2008-01-01

    In Central European states, rates of HIV among IDUs have been low although HCV infection is widespread. The goal of our study was to assess HIV infection, risk perceptions and injecting equipment sharing among injection drug users in Budapest, Hungary. Altogether 150 IDUs were interviewed (121 structured between 1999-2000 and 29 ethnographic between 2003-2004). The majority of them injected heroin (52% and 79%) and many injected amphetamines (51% and 35%). One person tested positive for HIV. Two thirds (68% of 121) shared injecting equipment (syringes, cookers and filters). Some participants said they shared syringes because they were not carrying them for fear of police harassment, and that they reused filters as a backup drug supply. In multivariate analysis, sharing of injecting equipment was associated with higher perceived susceptibility to HIV/AIDS, lower self-efficacy for sterile equipment use, higher motivation to comply with peer pressure to use dirty injecting equipment, and with having a criminal record. The high levels of injecting risk behaviors found in this study are a cause for serious concern. HIV prevention interventions need to address not only sharing syringes but also sharing and reusing other injecting equipment and drug filters. PMID:17129858

  11. Fabrication and modelling of injection moulded all-polymer capillary microvalves for passive microfluidic control

    International Nuclear Information System (INIS)

    Kistrup, Kasper; Østergaard, Peter Friis; Taboryski, Rafael; Wolff, Anders; Hansen, Mikkel Fougt; Haugshøj, Kenneth Brian; Poulsen, Carl Esben

    2014-01-01

    Rapid prototyping is desirable when developing products. One example of such a product is all-polymer, passive flow controlled lab-on-a-chip systems that are preferential when developing low-cost disposable chips for point-of-care use. In this paper we investigate the following aspects of going from rapid prototyping to pilot (mass) production. (1) Fabrication of an all-polymer microfluidic system using a rapid prototyped master insert for injection moulding and ultrasonic welding, including a systematic experimental characterisation of chip featured geometric capillary microvalve test structures. (2) Numerical modelling of the microvalve burst pressures. Numerical modelling of burst pressures is challenging due to its non-equilibrium nature. We have implemented and tested the level-set method modified with a damped driving term and show that the introduction of the damping term leads to numerically robust results with limited computational demands and a low number of iterations. Numerical and simplified analytical results are validated against the experimental results. We find that injection moulding and ultrasonic welding are effective for chip production and that the experimental burst pressures could be estimated with an average accuracy of 5% using the presented numerical model. (paper)

  12. Groundwater monitoring for deep-well injection

    International Nuclear Information System (INIS)

    Chia, Y.; Chiu, J.

    1994-01-01

    A groundwater monitoring system for detecting waste migration would not only enhance confidence in the long-term containment of injected waste, but would also provide early warnings of contamination for prompt responses to protect underground sources of drinking water (USDWs). Field experiences in Florida have demonstrated monitoring water quality and fluid pressure changes in overlying formations is useful in detecting the upward migration of injected waste. Analytical and numerical solutions indicate changes in these two monitoring parameters can vary on the basis of hydrogeologic characteristics, operation conditions, and the distances from the injection well to the monitoring wells and to the preferential hydrologic conduits. To detect waste migration through defects around the wellbore or the leaky containment interval, groundwater monitoring wells should be placed as close as possible to an injection well. In the vertical direction, a monitoring well completed in a permeable interbed within the containment interval is expected to have the highest potential for detecting upward migration. Another acceptable horizon for groundwater monitoring is the lower portion of the buffer brine aquifer immediately above the containment interval. Monitoring wells in USDWs may be needed when waste has been detected in deeper formations or when leakage out of well casings poses a concern. A monitoring well open to the injection interval is of little value in alleviating the concerns of long-term upward migration. Moreover, the installation of the well could create additional preferential pathways. Complications in groundwater monitoring may arise at existing injection sites, especially with prior releases. It is also important to recognize that monitoring in the vicinity of the wellbore may not be effective for detecting waste migration through unidentified unplugged wells or undetected transmissive fractures

  13. Predicting, monitoring and controlling geomechanical effects of CO2 injection

    International Nuclear Information System (INIS)

    Streit, J.E.; Siggins, A.F.

    2005-01-01

    A key objective of geological carbon dioxide (CO 2 ) storage in porous rock is long-term subsurface containment of CO 2 . Fault stability and maximum sustainable pore-fluid pressures should be estimated in geomechanical studies in order to avoid damage to reservoir seals and fault seals of storage sites during CO 2 injection. Such analyses rely on predicting the evolution of effective stresses in rocks and faults during CO 2 injection. However, geomechanical analyses frequently do not incorporate poroelastic behaviour of reservoir rock, as relevant poroelastic properties are rarely known. The knowledge of rock poroelastic properties would allow the use of seismic methods for the accurate measurement of the effective stress evolution during CO 2 injection. This paper discussed key geomechanical effects of CO 2 injection into porous rock, and in particular, focused on the effects that the poroelasticity of reservoir rocks and pore pressure/stress coupling have on effective stresses. Relevant geophysical monitoring techniques were also suggested. The paper also outlined how these techniques could be applied to measure stress changes related to poroelastic rock behaviour during CO 2 injection and to test the predictions of sustainable changes in effective stress in CO 2 storage sites. It was concluded that a combination of predictive geomechanical techniques and application of geophysical monitoring techniques is a valid new concept for controlling and monitoring the geomechanical effects of CO 2 storage. 36 refs., 5 figs

  14. Bladder base/trigone injection is safe and as effective as bladder body injection of onabotulinumtoxinA for idiopathic detrusor overactivity refractory to antimuscarinics.

    Science.gov (United States)

    Kuo, Hann-Chorng

    2011-09-01

    The purpose of this study was to evaluate the efficacy and safety of onabotulinumtoxinA injections at bladder base/trigone and compare with injections at bladder body or bladder body/trigone for the treatment of idiopathic detrusor overactivity (IDO) refractory to antimuscarinics. A single blind, randomized, paralleled, actively controlled trial was performed in patients with urodynamically proven IDO who failed antimuscarinic therapy. Patients were randomly assigned to receive intravesical injections of 100 U of onabotulinumtoxinA into three different bladder sites. All treatments were evaluated by voiding diary variables, urgency severity score, urodynamic studies, and patient perception of bladder condition. Long-term success rates over 12 months were also determined. Among the patients, 37 were randomized to injections in the bladder body, 35 into the bladder body/trigone, and 33 into the bladder base/trigone. Successful results were reported in 76 (72%) patients at 3 months: 26 (70%) in the bladder body group, 26 (74%) in the bladder body/trigone group, and 24 (73%) in the bladder base/trigone group. There were no significant differences in success rates, changes in urgency and urgency incontinence episodes, urodynamic variables, or long-term success rates among the three subgroups. The incidence of adverse events was similar among three groups. No vesicoureteral reflux was noted in all patients with or without involving trigone injection. Intravesical onabotulinumtoxinA injection is an effective treatment for IDO regardless of the bladder injection site. Bladder base/trigone injection is as safe and effective as bladder body injections with or without trigone involvement. Copyright © 2011 Wiley-Liss, Inc.

  15. Sector Tests of a Low-NO(sub x), Lean, Direct- Injection, Multipoint Integrated Module Combustor Concept Conducted

    Science.gov (United States)

    Tacina, Robert R.; Wey, Chang-Lie; Laing, Peter; Mansour, Adel

    2002-01-01

    The low-emissions combustor development described is directed toward advanced high pressure aircraft gas-turbine applications. The emphasis of this research is to reduce nitrogen oxides (NOx) at high-power conditions and to maintain carbon monoxide and unburned hydrocarbons at their current low levels at low power conditions. Low-NOx combustors can be classified into rich-burn and lean-burn concepts. Lean-burn combustors can be further classified into lean-premixed-prevaporized (LPP) and lean direct injection (LDI) concepts. In both concepts, all the combustor air, except for liner cooling flow, enters through the combustor dome so that the combustion occurs at the lowest possible flame temperature. The LPP concept has been shown to have the lowest NOx emissions, but for advanced high-pressure-ratio engines, the possibility of autoignition or flashback precludes its use. LDI differs from LPP in that the fuel is injected directly into the flame zone, and thus, it does not have the potential for autoignition or flashback and should have greater stability. However, since it is not premixed and prevaporized, good atomization is necessary and the fuel must be mixed quickly and uniformly so that flame temperatures are low and NOx formation levels are comparable to those of LPP. The LDI concept described is a multipoint fuel injection/multiburning zone concept. Each of the multiple fuel injectors has an air swirler associated with it to provide quick mixing and a small recirculation zone for burning. The multipoint fuel injection provides quick, uniform mixing and the small multiburning zones provide for reduced burning residence time, resulting in low NOx formation. An integrated-module approach was used for the construction where chemically etched laminates, diffusion bonded together, combine the fuel injectors, air swirlers, and fuel manifold into a single element. The multipoint concept combustor was demonstrated in a 15 sector test. The configuration tested had 36

  16. An experimental study on the thermal-hydraulic phenomena in the Hybrid Safety Injection Tank using a separate effect test facility

    International Nuclear Information System (INIS)

    Ryu, Sung Uk; Ryu, Hyobong; Park, Hyun-Sik; Yi, Sung-Jae

    2016-01-01

    Highlights: • The experimental study on the pressure balancing between the Hybrid SIT and PZR. • The effects of different variables affecting the pressure balancing are investigated. • A sensitivity analysis on the pressure variations of the Hybrid SIT. - Abstract: This paper reports an experimental research for investigating thermal hydraulic phenomena of Hybrid Safety Injection Tank (Hybrid SIT) using a separate effect test facility in Korea Atomic Energy Research Institute (KAERI). The Hybrid SIT is a passive safety injection system that enables the safety injection water to be injected into the reactor pressure vessel throughout all operating pressures by connecting the top of the SIT and the pressurizer (PZR). The separate effect test (SET) facility of Hybrid SIT, which is designed based on the APR+ power plant, comprises a PZR, Hybrid SIT, pressure balancing line (PBL), injection line (IL), nitrogen gas line, and refueling water tank (RWT). Furthermore, the pressure loss range of the SET facility was analyzed and compared with that of the reference nuclear power plant. In this research, a condition for balancing the pressure between the Hybrid SIT and PZR is examined and the effects of different variables affecting the pressure balancing, which are flow rate, injection velocity of steam and initial water level, are also investigated. The condition for balancing the pressure between the Hybrid SIT and PZR was derived theoretically from a pressure network for the Hybrid SIT, pressurizer, and reactor pressure vessel. Additionally, a sensitivity analysis as a theoretical approach was conducted on the pressure variations in relation to the rate of steam condensation inside the Hybrid SIT. The results showed that pressure of the Hybrid SIT was predominantly determined by the rate of steam condensation. The results showed that if the rate of condensation increased or decreased by 10%, the Hybrid SIT pressure at the pressure balancing point decreased or

  17. Incidence of plantar fascia ruptures following corticosteroid injection.

    Science.gov (United States)

    Kim, Chul; Cashdollar, Michael R; Mendicino, Robert W; Catanzariti, Alan R; Fuge, LaDonna

    2010-12-01

    Plantar fasciitis is commonly treated with corticosteroid injections to decrease pain and inflammation. Therapeutic benefits often vary in terms of efficacy and duration. Rupture of the plantar fascia has been reported as a possible complication following corticosteroid injection. A retrospective chart review of 120 patients who received corticosteroid injection for plantar fasciitis was performed at the authors' institution to determine the incidence of plantar fascia rupture. The plantar fascia rupture was diagnosed clinically and confirmed with magnetic resonance imaging. Various factors were analyzed, including the number of injections, interval between injections, body mass index (BMI), and activity level. Four patients (2.4%) consequently experienced plantar fascia rupture following an average of 2.67 injections. The average BMI of these patients was 38.6 kg/m². The authors conclude that corticosteroid injection therapy appears to be a safe and effective form of nonoperative treatment with minimal complications and a relatively low incident of plantar fascia rupture.

  18. Autologous Blood Injection Works for Recalcitrant Lateral Epicondylitis.

    Science.gov (United States)

    Bostan, Bora; Balta, Orhan; Aşçı, Murat; Aytekin, Kürşad; Eser, Enes

    2016-03-01

    Recalcitrant lateral epicondylitis may be a disabling condition. Treatment of this condition is still controversial. In the present prospective study, we evaluated the long-term results of autologous blood injection for the treatment of recalcitrant lateral epicondylitis. Prospective clinical study. A total of 42 elbows of 40 consecutive patients (28 female, 12 male) were enrolled in this prospective study. Seven patients left the study (3 patients moved to another city, 1 patient died in the second week due to a heart condition, 1 patient quit the study because of the resolution of pain in the fourth week and 2 patients did not agree to the second injection). Thirteen patients were lost to third year follow-up. Therefore, a total of 21 elbows of 20 patients with 3 years of follow-up were included in this study. The mean age of the patients was 47.25 years (range, 20-68 years). Visual analogue scale (VAS), Nirschl score and grip strength were significantly improved after injections when compared to before treatment. The best improvement in terms of grip strength, Nirschl score and VAS score was detected at the one year follow-up. The improvement in Nirschl and VAS score sustained until the third year. We suggest that autologous blood injection for the treatment of recalcitrant lateral epicondylitis is an effective, safe and successful procedure in the long-term.

  19. Safe and successful endoscopic initial treatment and long-term eradication of gastric varices by endoscopic ultrasound-guided Histoacryl (N-butyl-2-cyanoacrylate) injection.

    Science.gov (United States)

    Gubler, Christoph; Bauerfeind, Peter

    2014-09-01

    Optimal endoscopic treatment of gastric varices is still not standardized nowadays. Actively bleeding varices may prohibit a successful endoscopic injection therapy of Histoacryl® (N-butyl-2-cyanoacrylate). Since 2006, we have treated gastric varices by standardized endoscopic ultrasound (EUS) guided Histoacryl injection therapy without severe adverse events. We present a large single-center cohort over 7 years with a standardized EUS-guided sclerotherapy of all patients with gastric varices. Application was controlled by fluoroscopy to immediately detect any glue embolization. Only perforating veins located within the gastric wall were treated. In the follow up, we repeated this treatment until varices were eradicated. Utmost patients (36 of 40) were treated during or within 24 h of active bleeding. About 32.5% of patients were treated while visible bleeding. Histoacryl injection was always technically successful and only two patients suffered a minor complication. Acute bleeding was stopped in all patients. About 15% (6 of 40) of patients needed an alternative rescue treatment in the longer course. Three patients got a transjugular portosystemic shunt and another three underwent an orthotopic liver transplantation. Mean long-term survival of 60 months was excellent. Active bleeding of gastric varices can be treated successfully without the necessity of gastric rinsing with EUS-guided injection of Histoacryl.

  20. Challenges in defining a radiologic and hydrologic source term for underground nuclear test centers, Nevada Test Site, Nye County, Nevada

    International Nuclear Information System (INIS)

    Smith, D.K.

    1995-06-01

    The compilation of a radionuclide inventory for long-lived radioactive contaminants residual from nuclear testing provides a partial measure of the radiologic source term at the Nevada Test Site. The radiologic source term also includes potentially mobile short-lived radionuclides excluded from the inventory. The radiologic source term for tritium is known with accuracy and is equivalent to the hydrologic source term within the saturated zone. Definition of the total hydrologic source term for fission and activation products that have high activities for decades following underground testing involves knowledge and assumptions which are presently unavailable. Systematic investigation of the behavior of fission products, activation products and actinides under saturated or Partially saturated conditions is imperative to define a representative total hydrologic source term. This is particularly important given the heterogeneous distribution of radionuclides within testing centers. Data quality objectives which emphasize a combination of measurements and credible estimates of the hydrologic source term are a priority for near-field investigations at the Nevada Test Site

  1. Notes on power of normality tests of error terms in regression models

    International Nuclear Information System (INIS)

    Střelec, Luboš

    2015-01-01

    Normality is one of the basic assumptions in applying statistical procedures. For example in linear regression most of the inferential procedures are based on the assumption of normality, i.e. the disturbance vector is assumed to be normally distributed. Failure to assess non-normality of the error terms may lead to incorrect results of usual statistical inference techniques such as t-test or F-test. Thus, error terms should be normally distributed in order to allow us to make exact inferences. As a consequence, normally distributed stochastic errors are necessary in order to make a not misleading inferences which explains a necessity and importance of robust tests of normality. Therefore, the aim of this contribution is to discuss normality testing of error terms in regression models. In this contribution, we introduce the general RT class of robust tests for normality, and present and discuss the trade-off between power and robustness of selected classical and robust normality tests of error terms in regression models

  2. Notes on power of normality tests of error terms in regression models

    Energy Technology Data Exchange (ETDEWEB)

    Střelec, Luboš [Department of Statistics and Operation Analysis, Faculty of Business and Economics, Mendel University in Brno, Zemědělská 1, Brno, 61300 (Czech Republic)

    2015-03-10

    Normality is one of the basic assumptions in applying statistical procedures. For example in linear regression most of the inferential procedures are based on the assumption of normality, i.e. the disturbance vector is assumed to be normally distributed. Failure to assess non-normality of the error terms may lead to incorrect results of usual statistical inference techniques such as t-test or F-test. Thus, error terms should be normally distributed in order to allow us to make exact inferences. As a consequence, normally distributed stochastic errors are necessary in order to make a not misleading inferences which explains a necessity and importance of robust tests of normality. Therefore, the aim of this contribution is to discuss normality testing of error terms in regression models. In this contribution, we introduce the general RT class of robust tests for normality, and present and discuss the trade-off between power and robustness of selected classical and robust normality tests of error terms in regression models.

  3. Injection error monitor for KEK 12 GeV PS

    International Nuclear Information System (INIS)

    Shirakata, Masashi; Sato, Hikaru; Toyama, Takeshi; Marutsuka, Katsumi.

    1994-01-01

    The injection error monitor is now developing for an easy tuning of the main ring beam injection at the KEK 12 GeV proton synchrotron. The beam trajectory on the horizontal phase space plane is obtained by a test bench system. The injection error monitor proved to be available for the beam injection tuning. (author)

  4. Advocacy for Gender Affirming Care: Learning from the Injectable Estrogen Shortage.

    Science.gov (United States)

    Geffen, Sophia; Horn, Tim; Smith, Kimberleigh Joy; Cahill, Sean

    2018-01-01

    Hormone therapy is medically necessary for many transgender individuals. The U.S. Food and Drug Administration (FDA) and pharmaceutical companies' failure to guarantee a supply of injectable estrogen in 2016 and 2017 for transgender individuals is a violation of their right to comprehensive medical treatment, free of discrimination. A series of advocacy actions eventually led to all formulations of injectable estrogen being restored to market; however, long-term solutions to supply interruptions of injectable estrogen are needed. Long-term solutions should address the lack of federally funded research and, consequently, evidence-based practice on hormone therapy for gender affirmation.

  5. Testing and modelling of a novel oil-free co-rotating scroll machine with water injection

    International Nuclear Information System (INIS)

    Mendoza, Luis Carlos; Lemofouet, Sylvain; Schiffmann, Jürg

    2017-01-01

    Highlights: • Performance of novel oil-free co-rotating scroll expander presented. • Water injection allows reaching quasi-isothermal expansion process. • Comparison between experimental data, semi-empirical and deterministic models. • Flank leakage, water injection and rotor speed effects have been analyzed experimentally. • Design guidelines for co-rotating scroll improvement proposed. - Abstract: Efficient compressed air energy storage requires reversible isothermal compression and expansion devices. The isothermal compression and expansion processes can either be approached by several stages with intercooling or by the more convenient injection of a liquid, often water. While volumetric machines are readily available for dry processes the compression and expansion of a gas with the presence of liquid is still problematic. The concept of a co-rotating scroll has been identified as a promising technology to cope with the presence of liquid. The current paper discusses the first experimental results of an oil-free co-rotating scroll prototype tested in expansion mode on a wide range of rotational speeds, varying water injection flow rates and with different nominal flank clearances. A maximal overall isothermal efficiency of 34% and a maximum output power of 1.74 kW_e_l were measured with this first prototype, providing the proof of the technical feasibility of the oil-free co-rotating scroll expander concept. The experimental data indicate a positive effect of water injection suggesting good heat transfer behaviour between the water and the air in the individual chambers, which is a result of the relatively long residence time compared to other volumetric concepts. The experimental sensitivity analysis yields a strong dependency of the machine performance on both the nominal flank clearance and on the injected water rate. The analysis through a semi-empirical model suggests the inversion of a classical trend, i.e. the increase in total leakage area with

  6. Human and bovine spinal disc mechanics subsequent to trypsin injection.

    Science.gov (United States)

    Alsup, Jeremy; Bishop, Timothy; Eggett, Dennis; Bowden, Anton E

    2017-10-01

    To investigate the biomechanical effects of injections of a protease on the characteristics of bovine coccygeal and human lumbar disc motion segments. Mechanics of treated tissues were measured immediately after injection and 3 h after injection. Motion segments underwent axial rotation and flexion-extension loading. Stiffness and neutral zone parameters experienced significant changes over time, with bovine tissues more strongly affected than human cadaver tissues. This was true in both axial rotation and flexion-extension. The treatment type significantly affected the neutral zone measurements in axial rotation. Hysteresis parameters were impacted by control injections. The extrapolation of bovine coccygeal motion testing results to human lumbar disc mechanics is not yet practical. The injected treatment may have a smaller impact on disc mechanics than time in testing. Viscoelasticity of human lumbar discs may be impacted by any damage to the annulus fibrosis induced by needlestick. Preclinical testing of novel spinal devices is essential to the design validation and regulatory processes, but current testing techniques rely on cadaveric testing of primarily older spines with essentially random amounts of disc degeneration. The present work investigates the viability of using trypsin injections to create a more uniform preclinical model of disc degeneration from a mechanics perspective, for the purpose of testing spinal devices. Such a model would facilitate translation of new spinal technologies to clinical practice.

  7. Percutaneous ethanol injection of hyperfunctioning thyroid nodules: long-term follow-up in 125 patients.

    Science.gov (United States)

    Tarantino, Luciano; Francica, Giampiero; Sordelli, Ignazio; Sperlongano, Pasquale; Parmeggiani, Domenico; Ripa, Carmine; Parmeggiani, Umberto

    2008-03-01

    The purpose of this study was to assess the long-term efficacy of percutaneous ethanol injection (PEI) for the treatment of hyperfunctioning thyroid nodules. One hundred twenty-five patients (88 women, 37 men; age range, 17-76 years; mean age, 53 years) with 127 hyperfunctioning thyroid nodules (volume, 1.2-90 mL; mean, 10.3 mL) were treated with PEI. There were 1-11 PEI sessions per patient (average, 3.9) performed, with injection of 1-14 mL of ethanol per session (total injected ethanol per patient, 3-108 mL; mean, 14.0 mL). Efficacy of the treatment was assessed with color Doppler sonography; scintigraphy; and free triiodothyronine (FT3), free thyroxine (FT4), and thyroid-stimulating hormone (TSH) assays. Follow-up (9-144 months; median, 60 months) was performed with TSH and color Doppler sonography every 2 months for 6 months and every 6 months thereafter. Three (2.4%) of 125 patients refused completion of PEI therapy because of pain. Results are reported in 122 patients with 124 nodules. All 122 patients showed posttreatment normal levels of FT3, FT4, and TSH. A complete cure (absent uptake in the nodule and recovery of normal uptake in the thyroid parenchyma) was obtained in 113 (93%) of 122 patients-115 (92.7%) of 124 treated nodules. Residual hyperfunctioning nodular tissue along with decreased thyroid parenchyma uptake (partial cure) was present in nine patients accounting for nine (7.3%) of 124 nodules. Rates of complete cure after PEI were: overall nodules, 115 (92.7%) of 124; nodules nodules > 10 to nodules > 30 to nodules > 60 mL, three (100%) of three. The overall rate of major complications (transient laryngeal nerve damage, two patients; abscess and hematoma, one patient each) was four (3.2%) of 125 patients. Follow-up examinations showed marked shrinkage of 112 treated nodules ranging from 50% to 90% of the pretreatment volume (mean, 66%) and new growth of hyperfunctioning tissue in four patients at color Doppler sonography and scintigraphy at 12

  8. Change of cholinergic transmission and memory deficiency induced by injection of b-amyloid protein into NBM of rats

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    The change of cholinergic transmission of b-amyloid protein (b-AP) treated rats was studied by intracerebral microdialysis sampling combined with HPLC analysis. b-AP1-40 was injected into nucleus basalis magnocellularis (NBM). Passive avoidance response test (step-down test) and delayed alternation task were used for memory testing. The impairment of memory after injection of b-AP1-40 into NBM exhibited mainly the deficiency of short-term working memory. One week after injection of b-AP1-40 the release of acetylcholine (ACh) from frontal cortex of freely-moving rats decreased significantly, and the response of cholinergic nerve ending to the action of high [K+] solution was rather weak. In control animals the percentage of increase of ACh- release during behavioral performance was 57%, while in b-AP1-40 - treated rats it was 34%. The temporary in-crease of the ACh-release of the rat put into a new place was also significantly diminished in b-AP1-40 -treated rats. The results show that the injection of b-AP1-40 into NBM impairs the cholinergic transmission in frontal cortex, and the impairment of cholinergic transmission may be the main cause of the deficit of working memory.

  9. Influence of Injector Location on Part-Load Performance Characteristics of Natural Gas Direct-Injection in a Spark Ignition Engine

    Energy Technology Data Exchange (ETDEWEB)

    Sevik, James [Argonne National Lab. (ANL), Argonne, IL (United States); Pamminger, Michael [Argonne National Lab. (ANL), Argonne, IL (United States); Wallner, Thomas [Argonne National Lab. (ANL), Argonne, IL (United States); Scarcelli, Riccardo [Argonne National Lab. (ANL), Argonne, IL (United States); Boyer, Brad [Ford Motor Co., Detroit, MI (United States); Wooldridge, Steven [Ford Motor Co., Detroit, MI (United States); Hall, Carrie [Illinois Inst. of Technology, Chicago, IL (United States); Miers, Scott [Michigan Technological Univ., Houghton, MI (United States)

    2016-04-05

    Interest in natural gas as an alternative fuel source to petroleum fuels for light-duty vehicle applications has increased due to its domestic availability and stable price compared to gasoline. With its higher hydrogen-to-carbon ratio, natural gas has the potential to reduce engine out carbon dioxide emissions, which has shown to be a strong greenhouse gas contributor. For part-load conditions, the lower flame speeds of natural gas can lead to an increased duration in the inflammation process with traditional port-injection. Direct-injection of natural gas can increase in-cylinder turbulence and has the potential to reduce problems typically associated with port-injection of natural gas, such as lower flame speeds and poor dilution tolerance. A study was designed and executed to investigate the effects of direct-injection of natural gas at part-load conditions. Steady-state tests were performed on a single-cylinder research engine representative of current gasoline direct-injection engines. Tests were performed with direct-injection in the central and side location. The start of injection was varied under stoichiometric conditions in order to study the effects on the mixture formation process. In addition, exhaust gas recirculation was introduced at select conditions in order to investigate the dilution tolerance. Relevant combustion metrics were then analyzed for each scenario. Experimental results suggest that regardless of the injector location, varying the start of injection has a strong impact on the mixture formation process. Delaying the start of injection from 300 to 120°CA BTDC can reduce the early flame development process by nearly 15°CA. While injecting into the cylinder after the intake valves have closed has shown to produce the fastest combustion process, this does not necessarily lead to the highest efficiency, due to increases in pumping and wall heat losses. When comparing the two injection configurations, the side location shows the best

  10. Equipment for long-term testing of material creep in liquid sodium

    International Nuclear Information System (INIS)

    Dufek, F.; Walder, V.; Cech, V.; Winkler, P.

    1980-01-01

    A sodium test plant is described and the methods are shown of securing the desired test specifications. The facility is used for the long-term testing of nonsteady material creep under the action of temperature and mechanical stress due to the static or pulsed overpressure of inert gas inside a tube specimen and a simultaneous effect of sodium flow on the outside wall. The test results are to be used for comparing Czechoslovak-made steels with foreign materials and also for testing the degradation effects of the above phenomena on the standardized long-term properties in inert and steady state conditions. (B.S.)

  11. Re-injection feasibility study of fracturing flow-back fluid in shale gas mining

    Science.gov (United States)

    Kang, Dingyu; Xue, Chen; Chen, Xinjian; Du, Jiajia; Shi, Shengwei; Qu, Chengtun; Yu, Tao

    2018-02-01

    Fracturing flow-back fluid in shale gas mining is usually treated by re-injecting into formation. After treatment, the fracturing flow-back fluid is injected back into the formation. In order to ensure that it will not cause too much damage to the bottom layer, feasibility evaluations of re-injection of two kinds of fracturing fluid with different salinity were researched. The experimental research of the compatibility of mixed water samples based on the static simulation method was conducted. Through the analysis of ion concentration, the amount of scale buildup and clay swelling rate, the feasibility of re-injection of different fracturing fluid were studied. The result shows that the swelling of the clay expansion rate of treated fracturing fluid is lower than the mixed water of treated fracturing fluid and the distilled water, indicating that in terms of clay expansion rate, the treated fracturing flow-back fluid is better than that of water injection after re-injection. In the compatibility test, the maximum amount of fouling in the Yangzhou oilfield is 12mg/L, and the maximum value of calcium loss rate is 1.47%, indicating that the compatibility is good. For the fracturing fluid with high salinity in the Yanchang oilfield, the maximum amount of scaling is 72mg/L, and the maximum calcium loss rate is 3.50%, indicating that the compatibility is better.

  12. Physical characterization and modeling of chitosan/peg blends for injectable scaffolds.

    Science.gov (United States)

    Lima, Daniel B; Almeida, Renata D; Pasquali, Matheus; Borges, Sílvia P; Fook, Marcus L; Lisboa, Hugo M

    2018-06-01

    Injectable scaffolds find many applications on the biomedical field due to several advantages on preformed scaffolds such as being able to fill any defect can be used in minimal invasion surgeries and are ready to use products. The most critical parameter for an injectable scaffold usage is its injectability, which can be related with rheological properties. Therefore, the objective of the present work was to increase knowledge about the critical parameters influencing injectability of biopolymers used for injectable scaffolds. Rheological and mechanical properties of a biopolymer blend in combination with injectability tests for a given design space controlled by the concentrations of both polymers and temperatures was made. Then those results were modeled to better understand the impact of parameters on injectability. The biopolymer blend chosen was Chitosan physically blended with Poly(ethylene glycol) where variations of both polymer concentrations and molecular weights were tested. Rheological and mechanical properties of all samples were determined, together with the injection force using a compression test at different injection conditions. All solutions were clear and transparent suggesting perfect miscibility. Rheological results were modeled using Ostwald-Waelle law and revealed a shear thinning pseudo-plastic solution at any composition and temperature, being chitosan concentration the most influencing variable. Compression tests results revealed mean injection forces ranging from 9.9 ± 0.06N to 29.9 ± 0.65N and it was possible to accurately estimate those results. Simulations revealed draw speed as the most influencing parameter. Cell viability tests revealed a non-cytotoxic biopolymer blend. Copyright © 2018 Elsevier Ltd. All rights reserved.

  13. Reduced injection pressures using a compressed air injection technique (CAIT): an in vitro study.

    Science.gov (United States)

    Tsui, Ban C H; Knezevich, Mark P; Pillay, Jennifer J

    2008-01-01

    High injection pressures have been associated with intraneural injection and persistent neurological injury in animals. Our objective was to test whether a reported simple compressed air injection technique (CAIT) would limit the generation of injection pressures to below a suggested 1,034 mm Hg limit in an in vitro model. After ethics board approval, 30 consenting anesthesiologists injected saline into a semiclosed system. Injection pressures using 30 mL syringes connected to a 22 gauge needle and containing 20 mL of saline were measured for 60 seconds using: (1) a typical "syringe feel" method, and (2) CAIT, thereby drawing 10 mL of air above the saline and compressing this to 5 mL prior to and during injections. All anesthesiologists performed the syringe feel method before introduction and demonstration of CAIT. Using CAIT, no anesthesiologist generated pressures above 1,034 mm Hg, while 29 of 30 produced pressures above this limit at some time using the syringe feel method. The mean pressure using CAIT was lower (636 +/- 71 vs. 1378 +/- 194 mm Hg, P = .025), and the syringe feel method resulted in higher peak pressures (1,875 +/- 206 vs. 715 +/- 104 mm Hg, P = .000). This study demonstrated that CAIT can effectively keep injection pressures under 1,034 mm Hg in this in vitro model. Animal and clinical studies will be needed to determine whether CAIT will allow objective, real-time pressure monitoring. If high pressure injections are proven to contribute to nerve injury in humans, this technique may have the potential to improve the safety of peripheral nerve blocks.

  14. Single-use autoinjector for once-weekly intramuscular injection of IFNβ-1a.

    Science.gov (United States)

    Limmroth, Volker; Gerbershagen, Kathrin

    2014-12-01

    IFNβ products and glatiramer acetate are established treatment first-line options in long-term disease-modifying therapy of multiple sclerosis (MS). These self-injectable medications are used once weekly to once daily. Injection-related issues are common patient-cited reasons for nonadherence. Autoinjectors have been shown to support long-term adherence to injectable medications. The ability to self-inject in MS patients has been associated with a reduced risk of missed injections and drug discontinuation, and a beneficial effect on patient independence. The recently introduced easy-to-use prefilled once-weekly pen is a safe and effective device for intramuscular (IM) IFNβ-1a application and provides a convenient method for self-injection. We reviewed the available published evidence on the characteristics of this device. The once-weekly pen facilitates self-injection and was preferred over prefilled syringes by patients in a prospective open-label, multicenter Phase IIIb trial in MS patients who had been using IM IFNβ-1a in prefilled syringes. The simple and safe handling, shielded short needle, single-use disposable design and virtually painless injection by the device may contribute to adherence, quality of life and independence in patients using IM IFNβ-1a.

  15. Surface Deformation Observed by InSAR due to Fluid Injection: a Test Study in the Central U.S.

    Science.gov (United States)

    Deng, F.; Dixon, T. H.

    2017-12-01

    The central and eastern U.S. has undergone a dramatic increase in seismicity over the past few years. Many of these recent earthquakes were likely induced by human activities, with underground fluid injection for oil and gas extraction being one of the main contributors. Surface deformation caused by fluid injection has been captured by GPS and InSAR observations in several areas. For example, surface uplift of up to 10 cm due to CO2 injection between 2007 and 2011 was measured by InSAR at an enhanced oil recovery site in west Texas. We are using Texas and Oklahoma as test areas to analyze the potential relationship between surface deformation, underground fluid injection and induced earthquakes. C-band SAR data from ENVISAT and Sentinel-1, and L-band SAR data from ALOS and ALOS-2 are used to form decade-long time series. Based on the surface deformation derived from the time series InSAR data, subsurface volume change and volumetric strain in an elastic half space are estimated. Seismic data provided by the USGS are used to analyze the spatial and temporal distribution pattern of earthquakes, and the potential link between surface deformation and induced earthquakes. The trigger mechanism will be combined with forward modeling to predict seismicity and assess related hazard for future study.

  16. Browns Ferry Nuclear Plant: variation in test intervals for high-pressure coolant injection (HPCI) system

    International Nuclear Information System (INIS)

    Christie, R.F.; Stetkar, J.W.

    1985-01-01

    The change in availability of the high-pressure coolant injection system (HPCIS) due to a change in pump and valve test interval from monthly to quarterly was analyzed. This analysis started by using the HPCIS base line evaluation produced as part of the Browns Ferry Nuclear Plant (BFN) Probabilistic Risk Assessment (PRA). The base line evaluation showed that the dominant contributors to the unavailability of the HPCI system are hardware failures and the resultant downtime for unscheduled maintenance. The effect of changing the pump and valve test interval from monthly to quarterly was analyzed by considering the system unavailability due to hardware failures, the unavailability due to testing, and the unavailability due to human errors that potentially could occur during testing. The magnitude of the changes in unavailability affected by the change in test interval are discussed. The analysis showed a small increase in the availability of the HPCIS to respond to loss of coolant accidents (LOCAs) and a small decrease in the availability of the HPCIS to respond to transients which require HPCIS actuation. In summary, the increase in test interval from monthly to quarterly does not significantly impact the overall HPCIS availability

  17. Effect of feeding greater amounts of dietary energy for a short-term with or without eCG injection on reproductive performance, serum metabolites and hormones in ewes.

    Science.gov (United States)

    Habibizad, Javad; Riasi, Ahmad; Kohram, Hamid; Rahmani, Hamid Reza

    2015-09-01

    This study was conducted to compare the effect of transient high-energy diet in a short-term period with or without eCG injection on ovarian follicle development, twining rate, serum metabolites and hormones in ewes. A total of 45 estrous cyclic Naeini ewes were randomly assigned to three experimental groups: 1-Control (control), 2-High energy short-term feeding (HE), and 3-high energy short-term feeding + eCG injection (HEe). Ewes were housed in individual pens with free access to feed and water. The stage of the estrous cycle of all ewes was synchronized by insertion of intravaginal progesterone sponges. Focus feeding started from 4 days before until 1 day after sponge removal. Follicle development was monitored from 4 days before until 1 day after sponge removal and blood samples were taken during this time. Results showed that ewes fed high energy diets (HE and HEe) had greater (P ewes fed high energy diets had less (P ewes. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Autologous Blood Injection Works for Recalcitrant Lateral Epicondylitis

    Directory of Open Access Journals (Sweden)

    Bora Bostan

    2016-04-01

    Full Text Available Background: Recalcitrant lateral epicondylitis may be a disabling condition. Treatment of this condition is still controversial. Aims: In the present prospective study, we evaluated the long-term results of autologous blood injection for the treatment of recalcitrant lateral epicondylitis. Study Design: Prospective clinical study. Methods: A total of 42 elbows of 40 consecutive patients (28 female, 12 male were enrolled in this prospective study. Seven patients left the study (3 patients moved to another city, 1 patient died in the second week due to a heart condition, 1 patient quit the study because of the resolution of pain in the fourth week and 2 patients did not agree to the second injection. Thirteen patients were lost to third year follow-up. Therefore, a total of 21 elbows of 20 patients with 3 years of follow-up were included in this study. The mean age of the patients was 47.25 years (range, 20-68 years. Results: Visual analogue scale (VAS, Nirschl score and grip strength were significantly improved after injections when compared to before treatment. The best improvement in terms of grip strength, Nirschl score and VAS score was detected at the one year follow-up. The improvement in Nirschl and VAS score sustained until the third year. Conclusion: We suggest that autologous blood injection for the treatment of recalcitrant lateral epicondylitis is an effective, safe and successful procedure in the long-term.

  19. DOE/NETL's phase II mercury control technology field testing program: preliminary economic analysis of activated carbon injection.

    Science.gov (United States)

    Jones, Andrew P; Hoffmann, Jeffrey W; Smith, Dennis N; Feeley, Thomas J; Murphy, James T

    2007-02-15

    Based on results of field testing conducted by the U.S. Department of Energy's National Energy Technology Laboratory (DOE/NETL), this article provides preliminary costs for mercury control via conventional activated carbon injection (ACI), brominated ACI, and conventional ACI coupled with the application of a sorbent enhancement additive (SEA) to coal prior to combustion. The economic analyses are reported on a plant-specific basis in terms of the cost required to achieve low (50%), mid (70%), and high (90%) levels of mercury removal "above and beyond" the baseline mercury removal achieved by existing emission control equipment. In other words, the levels of mercury control are directly attributable to ACI. Mercury control costs via ACI have been amortized on a current dollar basis. Using a 20-year book life, levelized costs for the incremental increase in cost of electricity (COE), expressed in mills per kilowatt-hour (mills/kWh), and the incremental cost of mercury control, expressed in dollars per pound of mercury removed ($/lb Hg removed), have been calculated for each level of ACI mercury control. For this analysis, the increase in COE varied from 0.14 mills/kWh to 3.92 mills/kWh. Meanwhile, the incremental cost of mercury control ranged from $3810/lb Hg removed to $166000/lb Hg removed.

  20. Epidural steroid injection in patients with lumbosacral radiculopathy in Abuja, Nigeria

    Directory of Open Access Journals (Sweden)

    Ahidjo A Kawu

    2012-01-01

    Full Text Available Objective : This prospective-controlled observational study looked at well-matched patients with spinal pain and radicular symptoms, caused by lumbar intervertebral disc herniation to compare the short-term clinical outcome of transforaminal and interlaminar epidural steroid injection (ESI in a resource challenged tertiary institution in Nigeria. Materials and Methods : 49 patients with radicular symptoms who were matched for age, symptom duration, magnetic resonance imaging findings, and pre-injection revised Oswentry Disability Index (ODI score and Visual Analogue Scale (VAS were assigned into ESI technique. The ODI and VAS score were analyzed immediately after an injection and upon follow-up (average 178.5 days, also with the need for repeated injections and surgical interventions over a 1-year follow-up interval. Result: In the transforaminal group (25 patients, there was a statistically significant improvement in the ODI scores from before the injection (ODI mean 62.4 to immediately after the injection (ODI mean 24.4, P < 0.01, and upon follow-up (ODI mean 20.8, P < 0.01. 9 patients (18.4% required 1 or 2 repeated injections, 3 (6.1% patients underwent surgery and 2 (4% patients lost to follow-up. In the interlaminar group (24 patients, there was a statistically significant improvement in the ODI scores from before the injection (ODI mean 60.7 to immediately after the injection (ODI mean 30.1, P < 0.01, but not upon follow-up (ODI mean 43.2, P = 0.09. 11 (22.4% patients required 1 or 2 repeated injection, 4 (8% patients underwent surgery and 3 (6.1% patients were lost to follow-up. There is an average of 2 fold improvement of transforaminal ESI over interlaminar ESI in a 40 point scale of ODI score on follow-up, which was statistically significant (P < 0.01. The VAS showed similar pattern with the ODI scores in the study. Conclusion : Transforaminal ESI to treat symptomatic lumbar disc herniation resulted in better short-term pain

  1. Characteristics of pressure wave in common rail fuel injection system of high-speed direct injection diesel engines

    Directory of Open Access Journals (Sweden)

    Mohammad Reza Herfatmanesh

    2016-05-01

    Full Text Available The latest generation of high-pressure common rail equipment now provides diesel engines possibility to apply as many as eight separate injection pulses within the engine cycle for reducing emissions and for smoothing combustion. With these complicated injection arrangements, optimizations of operating parameters for various driving conditions are considerably difficult, particularly when integrating fuel injection parameters with other operating parameters such as exhaust gas recirculation rate and boost pressure together for evaluating calibration results. Understanding the detailed effects of fuel injection parameters upon combustion characteristics and emission formation is therefore particularly critical. In this article, the results and discussion of experimental investigations on a high-speed direct injection light-duty diesel engine test bed are presented for evaluating and analyzing the effects of main adjustable parameters of the fuel injection system on all regulated emission gases and torque performance. Main injection timing, rail pressure, pilot amount, and particularly pilot timing have been examined. The results show that optimization of each of those adjustable parameters is beneficial for emission reduction and torque improvement under different operating conditions. By exploring the variation in the interval between the pilot injection and the main injection, it is found that the pressure wave in the common rail has a significant influence on the subsequent injection. This suggests that special attentions must be paid for adjusting pilot timing or any injection interval when multi-injection is used. With analyzing the fuel amount oscillation of the subsequent injections to pilot separation, it demonstrates that the frequency of regular oscillations of the actual fuel amount or the injection pulse width with the variation in pilot separation is always the same for a specified fuel injection system, regardless of engine speed

  2. Sulfate Reduction Remediation of a Metals Plume Through Organic Injection

    International Nuclear Information System (INIS)

    Phifer, M.A.

    2003-01-01

    Laboratory testing and a field-scale demonstration for the sulfate reduction remediation of an acidic/metals/sulfate groundwater plume at the Savannah River Site has been conducted. The laboratory testing consisted of the use of anaerobic microcosms to test the viability of three organic substrates to promote microbially mediated sulfate reduction. Based upon the laboratory testing, soybean oil and sodium lactate were selected for injection during the subsequent field-scale demonstration. The field-scale demonstration is currently ongoing. Approximately 825 gallons (3,123 L) of soybean oil and 225 gallons (852 L) of 60 percent sodium lactate have been injected into an existing well system within the plume. Since the injections, sulfate concentrations in the injection zone have significantly decreased, sulfate-reducing bacteria concentrations have significantly increased, the pH has increased, the Eh has decreased, and the concentrations of many metals have decreased. Microbially mediated sulfate reduction has been successfully promoted for the remediation of the acidic/metals/sulfate plume by the injection of soybean oil and sodium lactate within the plume

  3. Geothermal Injection Monitoring in Klamath Falls, OR

    Energy Technology Data Exchange (ETDEWEB)

    Culver, G

    1990-01-01

    Klamath Falls has nearly a 150-year history of geothermal utilization. The geothermal aquifer has been the subject of many studies and is probably the most tested direct use reservoir in the world. This provides good background data for increased monitoring needed as new injection wells are drilled. Prior to July 1990, few injection wells existed. A city ordinance requires injection after July 1990. The city and major injectors have initiated a monitoring system.

  4. A Comparative Study on Energy and Exergy Analyses of a CI Engine Performed with Different Multiple Injection Strategies at Part Load: Effect of Injection Pressure

    Directory of Open Access Journals (Sweden)

    Muammer Özkan

    2015-01-01

    Full Text Available In this study, a four stroke four cylinder direct injection CI engine was run using three different injection pressures. In all measurements, the fuel quantity per cycle, the pre injection and main injection timing, the boost pressure and the engine speed were kept constant. The motor tests were performed under 130, 140 and 150 MPa rail pressure. During the theoretical part of the study, combustion, emission, energy and exergy analysis were made using the test results. An increase in the injection pressure increases combustion efficiency. The results show that combustion efficiency is not enough by itself, because the increase in the power need of the injection pump, decreases the thermal efficiency. The increase in the combustion temperature, increases the cooling loss and decreases the exergetic efficiency. In addition, the NOx emissions increased by 12% and soot emissions decreased 44% via increasing injection pressure by 17%. The thermal and exergetic efficiencies are found inversely proportional with injection pressure. Exergy destruction is found independent of the injection pressure and its value is obtained as ~6%.

  5. Accidental intra-arterial injection of fluorescein dye.

    Science.gov (United States)

    Bovino, J A; Marcus, D F

    1984-12-01

    During fluorescein angiography, sodium fluorescein dye intended for intravenous use was inadvertently injected into an artery in the antecubital fossa. An immediate and dramatic orange discoloration of the skin distal to the injection combined with intense burning pain of the right forearm and hand were noted. The patient was treated with ice packs and analgesics. The fluorescein angiogram showed a delayed arm to eye circulation time, but was of normal quality. There were no long-term complications.

  6. Particle balance studies in TEXTOR during experiments of pellet injection, helium injection, and ICR-heating

    International Nuclear Information System (INIS)

    Banno, T.; Finken, K.H.; Gray, D.S.; Winter, J.

    1995-01-01

    Analysis based on the particle conservation law has been carried out to observe the global fuelling process in tokamak discharges. The response of the net recycling flux from the first wall is investigated in the tokamak TEXTOR, using calibrated signals of the gas feed rate, the neutral gas pressure in the vessel, the total amount of electrons, and the particle removal rates by the ALT-II belt-pump limiter and by a main pump unit. Net absorption (pumping) of hydrogen by the wall is observed for almost all tokamak discharges since a new wall conditioning technique called siliconisation is employed. The net absorption or fuelling depending on the discharge condition influenced by injection of pellets, by helium gas injection combined with neutral beam injection, and by rf heating can be interpreted in terms of the particle-induced desorption effect with depth profile taken into consideration. ((orig.))

  7. Long-term follow-up of a case of intravenous elementary mercury injection

    International Nuclear Information System (INIS)

    Walter, E.

    1986-01-01

    Elementary mercury is usually intravenously injected with suicidal intent. It is floated to the heart and lungs but is also deposited in the abdominal organs. Case histories presented in the literature so far have been followed up clinically and roentgenologically for up to three years. We report one patient attempting suicidal mercury injection, whom we were able to follow up for 10 years. It could be demonstrated that quite in contrast to former suggestions elementary mercury is dissolved and oxidised in the body. Chronic poisoning with mercury compounds causes continuing damage, particularly to the kidneys. Apart from that question, the element's pattern of spread within the body, toxicological issues, particular pathologic anatomic changes, their demonstrability on X-ray films and their clinical relevance are all discussed in this paper. (orig.) [de

  8. Sensorless Control of IPMSM by Voltage Injection

    DEFF Research Database (Denmark)

    Matzen, Torben N.; Bech, Michael Møller

    2006-01-01

    In this paper a sensorless discrete current control of an Interior Permanent Magnet Synchrouns Motor (IPMSM) by voltage injection is designed and tested. The whole controller is operating in the dq-frame and for this reason the rotor position is essential to know, to transform between the station......In this paper a sensorless discrete current control of an Interior Permanent Magnet Synchrouns Motor (IPMSM) by voltage injection is designed and tested. The whole controller is operating in the dq-frame and for this reason the rotor position is essential to know, to transform between...... the stationary frame and the rotor xed dq-frame. To obtain the position even at standstill a sensorless scheme using voltage injection is added to the current controller....

  9. Safe injection procedures, injection practices, and needlestick ...

    African Journals Online (AJOL)

    Results: Safe injection procedures regarding final waste disposal were sufficiently adopted, while measures regarding disposable injection equipment, waste containers, hand hygiene, as well as injection practices were inadequately carried out. Lack of job aid posters that promote safe injection and safe disposal of ...

  10. Prospective testing of Coulomb short-term earthquake forecasts

    Science.gov (United States)

    Jackson, D. D.; Kagan, Y. Y.; Schorlemmer, D.; Zechar, J. D.; Wang, Q.; Wong, K.

    2009-12-01

    Earthquake induced Coulomb stresses, whether static or dynamic, suddenly change the probability of future earthquakes. Models to estimate stress and the resulting seismicity changes could help to illuminate earthquake physics and guide appropriate precautionary response. But do these models have improved forecasting power compared to empirical statistical models? The best answer lies in prospective testing in which a fully specified model, with no subsequent parameter adjustments, is evaluated against future earthquakes. The Center of Study of Earthquake Predictability (CSEP) facilitates such prospective testing of earthquake forecasts, including several short term forecasts. Formulating Coulomb stress models for formal testing involves several practical problems, mostly shared with other short-term models. First, earthquake probabilities must be calculated after each “perpetrator” earthquake but before the triggered earthquakes, or “victims”. The time interval between a perpetrator and its victims may be very short, as characterized by the Omori law for aftershocks. CSEP evaluates short term models daily, and allows daily updates of the models. However, lots can happen in a day. An alternative is to test and update models on the occurrence of each earthquake over a certain magnitude. To make such updates rapidly enough and to qualify as prospective, earthquake focal mechanisms, slip distributions, stress patterns, and earthquake probabilities would have to be made by computer without human intervention. This scheme would be more appropriate for evaluating scientific ideas, but it may be less useful for practical applications than daily updates. Second, triggered earthquakes are imperfectly recorded following larger events because their seismic waves are buried in the coda of the earlier event. To solve this problem, testing methods need to allow for “censoring” of early aftershock data, and a quantitative model for detection threshold as a function of

  11. Fabrication and modelling of injection moulded all-polymer capillary microvalves for passive microfluidic control

    DEFF Research Database (Denmark)

    Kistrup, Kasper; Poulsen, Carl Esben; Østergaard, Peter Friis

    2014-01-01

    Rapid prototyping is desirable when developing products. One example of such a product is all-polymer, passive flow controlled lab-on-a-chip systems that are preferential when developing low-cost disposable chips for point-of-care use. In this paper we investigate the following aspects of going...... from rapid prototyping to pilot (mass) production. (1) Fabrication of an all-polymer microfluidic system using a rapid prototyped master insert for injection moulding and ultrasonic welding, including a systematic experimental characterisation of chip featured geometric capillary microvalve test...... structures. (2) Numerical modelling of the microvalve burst pressures. Numerical modelling of burst pressures is challenging due to its non-equilibrium nature. We have implemented and tested the level-set method modified with a damped driving term and show that the introduction of the damping term leads...

  12. Collagenase injections for the treatment of single cords in cases of Dupuytren’s contracture – a prospective intervention study of long-term experience with Xiapex

    Directory of Open Access Journals (Sweden)

    Fischer, Lisa Maria

    2017-04-01

    Full Text Available Introduction: The gold standard in the treatment of Dupuytren’s contracture is surgical therapy. Alternatives are percutaneous needle fasciotomy and radiation in exceptional cases. Injection treatments with Xiapex (Pfizer are a new therapy option. This collagenase, extracted from clostridium histolyticum, is used to break down the affected tissue cords. The objective of this study is to examine the effect and long-term success of treatment with Xiapex.Methods: In this study, Xiapex treatment was conducted on a sample group of 19 patients with Dupuytren’s contracture. The injection was placed either on the cord at the level of the metacarpophalangeal (MCP joint (n=17 or of the proximal interphalangeal (PIP joint (n=7. Break-up of the cord occurred 24 hours after the injection. The neutral zero method was used to assess the extent of movement. The Michigan Hand Outcomes Questionnaire (MHQ was selected for evaluation of the general hand function in 16 patients. The WHO-5 and the EQ-5D VAS Score were used as a measure of the patients’ satisfaction and their state of health. All values were collected both pre-injection as well as 1 year post-injection.Results: Out of 19 patients in our sample group, 16 patients (≈84% benefitted in terms of improvement in mobility. Overall, the range of movement increased by Ø 26° in the affected finger. A separate assessment demonstrated that:The range of movement increased by 77% in the MCP joint. The extent of movement pre-injection was Ø (0-28-78 and post-injection it was Ø (0-9-81 with an improvement of Ø 22°. In the PIP joint, only slight improvement was observed (Ø pre (0-27-93; post (0-24-95.The MHQ increased from Ø 76% (R: 32–97% to 81% (R: 39–100%.The painfulness decreased from Ø 19% (R: 0–55% to Ø11% (R: 0–55%, corresponding to Ø 43%. Satisfaction increased in 72% of patients by Ø 21%.According to WHO-5, patient satisfaction pre-injection was Ø 20 (R: 11–25, and 1 year after

  13. Allergic anaphylaxis due to subcutaneously injected heparin

    Directory of Open Access Journals (Sweden)

    Anders Diana

    2013-01-01

    Full Text Available Abstract Heparins are one of the most used class of anticoagulants in daily clinical practice. Despite their widespread application immune-mediated hypersensitivity reactions to heparins are rare. Among these, the delayed-type reactions to s.c. injected heparins are well-known usually presenting as circumscribed eczematous plaques at the injection sites. In contrast, potentially life-threatening systemic immediate-type anaphylactic reactions to heparins are extremely rare. Recently, some cases of non-allergic anaphylaxis could be attributed to undesirable heparin contaminants. A 43-year-old patient developed severe anaphylaxis symptoms within 5–10 minutes after s.c. injection of enoxaparin. Titrated skin prick testing with wheal and flare responses up to an enoxaparin dilution of 1:10.000 indicated a probable allergic mechanism of the enoxaparin-induced anaphylaxis. The basophil activation test as an additional in-vitro test method was negative. Furthermore, skin prick testing showed rather broad cross-reactivity among different heparin preparations tested. In the presented case, history, symptoms, and results of skin testing strongly suggested an IgE-mediated allergic hypersensitivity against different heparins. Therefore, as safe alternative anticoagulants the patient could receive beneath coumarins the hirudins or direct thrombin inhibitors. Because these compounds have a completely different molecular structure compared with the heparin-polysaccharides.

  14. Associations between injection risk and community disadvantage among suburban injection drug users in southwestern Connecticut, USA.

    Science.gov (United States)

    Heimer, Robert; Barbour, Russell; Palacios, Wilson R; Nichols, Lisa G; Grau, Lauretta E

    2014-03-01

    Increases in drug abuse, injection, and opioid overdoses in suburban communities led us to study injectors residing in suburban communities in southwestern Connecticut, US. We sought to understand the influence of residence on risk and injection-associated diseases. Injectors were recruited by respondent-driven sampling and interviewed about sociodemographics, somatic and mental health, injection risk, and interactions with healthcare, harm reduction, substance abuse treatment, and criminal justice systems. HIV, hepatitis B and C (HBV and HCV) serological testing was also conducted. Our sample was consistent in geographic distribution and age to the general population and to the patterns of heroin-associated overdose deaths in the suburban towns. High rates of interaction with drug abuse treatment and criminal justice systems contrasted with scant use of harm reduction services. The only factors associated with both dependent variables-residence in less disadvantaged census tracts and more injection risk-were younger age and injecting in one's own residence. This contrasts with the common association among urban injectors of injection-associated risk behaviors and residence in disadvantaged communities. Poor social support and moderate/severe depression were associated with risky injection practices (but not residence in specific classes of census tracts), suggesting that a region-wide dual diagnosis approach to the expansion of harm reduction services could be effective at reducing the negative consequences of injection drug use.

  15. The short- and medium-term effectiveness of CT-guided selective cervical nerve root injection for pain and disability

    Energy Technology Data Exchange (ETDEWEB)

    Desai, Amidevi; Saha, Shouvik; Sharma, Naveen; Huckerby, Lauren; Houghton, Russell [Guy' s and St. Thomas' Hospitals, Department of Radiology, London (United Kingdom)

    2014-07-15

    CT-guided cervical nerve root injection with corticosteroid and/or local anesthetic is a recognized technique in the evaluation and treatment of cervical radiculopathy. There are few prospective studies on the efficacy of the various techniques employed in cervical nerve root injection. We present our results from a 1-year prospective series using a CT-guided anterolateral transforaminal approach for cervical nerve root injection of bupivacaine and dexamethasone. Pain using a numeric rating scale was assessed at pre-injection, 15 min post-injection, 1 month, and 3 months. Disability was assessed using the Oswestry Neck Disability Index (NDI) questionnaire at pre-injection, 1 month post-injection, and 3 months. In total, 50 patients were followed for 3 months. The mean reductions in pain were: 15 min (77 %), 1 month (39 %), and 3 months (33 %). The mean reductions in NDI were: 1 month (26 %) and 3 months (also 26 %). Results were statistically significant. CT-guided selective cervical nerve root injection in the treatment of cervical radicular pain and related disability produces statistically significant reductions in pain and disability to at least 3 months post-procedure. (orig.)

  16. The short- and medium-term effectiveness of CT-guided selective cervical nerve root injection for pain and disability

    International Nuclear Information System (INIS)

    Desai, Amidevi; Saha, Shouvik; Sharma, Naveen; Huckerby, Lauren; Houghton, Russell

    2014-01-01

    CT-guided cervical nerve root injection with corticosteroid and/or local anesthetic is a recognized technique in the evaluation and treatment of cervical radiculopathy. There are few prospective studies on the efficacy of the various techniques employed in cervical nerve root injection. We present our results from a 1-year prospective series using a CT-guided anterolateral transforaminal approach for cervical nerve root injection of bupivacaine and dexamethasone. Pain using a numeric rating scale was assessed at pre-injection, 15 min post-injection, 1 month, and 3 months. Disability was assessed using the Oswestry Neck Disability Index (NDI) questionnaire at pre-injection, 1 month post-injection, and 3 months. In total, 50 patients were followed for 3 months. The mean reductions in pain were: 15 min (77 %), 1 month (39 %), and 3 months (33 %). The mean reductions in NDI were: 1 month (26 %) and 3 months (also 26 %). Results were statistically significant. CT-guided selective cervical nerve root injection in the treatment of cervical radicular pain and related disability produces statistically significant reductions in pain and disability to at least 3 months post-procedure. (orig.)

  17. A longitudinal study of hepatitis C virus testing and infection status notification on behaviour change in people who inject drugs

    NARCIS (Netherlands)

    Spelman, T.; Morris, M. D.; Zang, G.; Rice, T.; Page, K.; Maher, L.; Lloyd, A.; Grebely, J.; Dore, G. J.; Kim, A. Y.; Shoukry, N. H.; Hellard, M.; Bruneau, J.; Cox, Andrea L.; Lauer, Georg; McGovern, Barbara H.; Prins, Maria; Hahn, Judy; Shiboski, Stephen; Mirzazadeh, Ali; Alavi, Maryam; Bouchard, Rachel; Evans, Jennifer; Grady, Bart; Aneja, Jasneet; Sacks-Davis, Rachel; Teutsch, Suzy; White, Bethany; Wells, Brittany; Applegate, Tanya; Matthews, Gail; Yeung, Barbara; Schinkel, Janke; Prince, Leslie Erin; Roy, Elise; Bates, Anna; Enriquez, Jarliene; Chow, Sammy; McCredie, Luke; Aitken, Campbell; Doyle, Joseph

    2015-01-01

    Background Hepatitis C virus (HCV) testing and counselling have the potential to impact individual behaviour and transmission dynamics at the population level. Evidence of the impact of an HCV-positive status notification on injection risk reduction is limited. The objective of our study was to (1)

  18. Pre-Test CFD for the Design and Execution of the Enhanced Injection and Mixing Project at NASA Langley Research Center

    Science.gov (United States)

    Drozda, Tomasz G.; Axdahl, Erik L.; Cabell, Karen F.

    2014-01-01

    With the increasing costs of physics experiments and simultaneous increase in availability and maturity of computational tools it is not surprising that computational fluid dynamics (CFD) is playing an increasingly important role, not only in post-test investigations, but also in the early stages of experimental planning. This paper describes a CFD-based effort executed in close collaboration between computational fluid dynamicists and experimentalists to develop a virtual experiment during the early planning stages of the Enhanced Injection and Mixing project at NASA Langley Research Center. This projects aims to investigate supersonic combustion ramjet (scramjet) fuel injection and mixing physics, improve the understanding of underlying physical processes, and develop enhancement strategies and functional relationships relevant to flight Mach numbers greater than 8. The purpose of the virtual experiment was to provide flow field data to aid in the design of the experimental apparatus and the in-stream rake probes, to verify the nonintrusive measurements based on NO-PLIF, and to perform pre-test analysis of quantities obtainable from the experiment and CFD. The approach also allowed for the joint team to develop common data processing and analysis tools, and to test research ideas. The virtual experiment consisted of a series of Reynolds-averaged simulations (RAS). These simulations included the facility nozzle, the experimental apparatus with a baseline strut injector, and the test cabin. Pure helium and helium-air mixtures were used to determine the efficacy of different inert gases to model hydrogen injection. The results of the simulations were analyzed by computing mixing efficiency, total pressure recovery, and stream thrust potential. As the experimental effort progresses, the simulation results will be compared with the experimental data to calibrate the modeling constants present in the CFD and validate simulation fidelity. CFD will also be used to

  19. Model complexity and choice of model approaches for practical simulations of CO2 injection, migration, leakage and long-term fate

    Energy Technology Data Exchange (ETDEWEB)

    Celia, Michael A. [Princeton Univ., NJ (United States)

    2016-12-30

    This report documents the accomplishments achieved during the project titled “Model complexity and choice of model approaches for practical simulations of CO2 injection,migration, leakage and long-term fate” funded by the US Department of Energy, Office of Fossil Energy. The objective of the project was to investigate modeling approaches of various levels of complexity relevant to geologic carbon storage (GCS) modeling with the goal to establish guidelines on choice of modeling approach.

  20. Fluid injection and induced seismicity

    Science.gov (United States)

    Kendall, Michael; Verdon, James

    2016-04-01

    The link between fluid injection, or extraction, and induced seismicity has been observed in reservoirs for many decades. In fact spatial mapping of low magnitude events is routinely used to estimate a stimulated reservoir volume. However, the link between subsurface fluid injection and larger felt seismicity is less clear and has attracted recent interest with a dramatic increase in earthquakes associated with the disposal of oilfield waste fluids. In a few cases, hydraulic fracturing has also been linked to induced seismicity. Much can be learned from past case-studies of induced seismicity so that we can better understand the risks posed. Here we examine 12 case examples and consider in particular controls on maximum event size, lateral event distributions, and event depths. Our results suggest that injection volume is a better control on maximum magnitude than past, natural seismicity in a region. This might, however, simply reflect the lack of baseline monitoring and/or long-term seismic records in certain regions. To address this in the UK, the British Geological Survey is leading the deployment of monitoring arrays in prospective shale gas areas in Lancashire and Yorkshire. In most cases, seismicity is generally located in close vicinity to the injection site. However, in some cases, the nearest events are up to 5km from the injection point. This gives an indication of the minimum radius of influence of such fluid injection projects. The most distant events are never more than 20km from the injection point, perhaps implying a maximum radius of influence. Some events are located in the target reservoir, but most occur below the injection depth. In fact, most events lie in the crystalline basement underlying the sedimentary rocks. This suggests that induced seismicity may not pose a leakage risk for fluid migration back to the surface, as it does not impact caprock integrity. A useful application for microseismic data is to try and forecast induced seismicity

  1. "The first shot": the context of first injection of illicit drugs, ongoing injecting practices, and hepatitis C infection in Rio de Janeiro, Brazil.

    Science.gov (United States)

    Oliveira, Maria de Lourdes Aguiar; Hacker, Mariana A; Oliveira, Sabrina Alberti Nóbrega de; Telles, Paulo Roberto; O, Kycia Maria Rodrigues do; Yoshida, Clara Fumiko Tachibana; Bastos, Francisco I

    2006-04-01

    The context of first drug injection and its association with ongoing injecting practices and HCV (hepatitis C virus) infection were investigated. Injection drug users (IDUs) (N = 606) were recruited in "drug scenes" (public places, bars) in Rio de Janeiro, Brazil, interviewed, and tested for HCV. Sharing of needles/syringes was more prevalent at the first injection (51.3%) than at the baseline interview (36.8%). Those who shared syringes/needles at first injection were more likely to be currently engaged in direct/indirect sharing practices. Among young injectors (drug injection were identified as independent predictors of HCV infection. To effectively curb HCV transmission among IDUs and minimize harms associated with risk behaviors, preventive strategies should target individuals initiating drug injection beginning with their very first injection and discourage the transition from non-injecting use to the self-injection of illicit drugs.

  2. LHC Injection Beam Quality During LHC Run I

    CERN Document Server

    AUTHOR|(CDS)2079186; Kain, Verena; Stapnes, Steinar

    The LHC at CERN was designed to accelerate proton beams from 450 GeV to 7 TeV and collide them in four large experiments. The 450 GeV beam is extracted from the last pre-accelerator, the SPS, and injected into the LHC via two 3 km long transfer lines, TI 2 and TI 8. The injection process is critical in terms of preservation of beam quality and machine protection. During LHC Run I (2009-2013) the LHC was filled with twelve high intensity injections per ring, in batches of up to 144 bunches of 1.7*10^11 protons per bunch. The stored beam energy of such a batch is already an order of magnitude above the damage level of accelerator equipment. Strict quality and machine protection requirements at injection have a significant impact on operational efficiency. During the first years of LHC operation, the injection phase was identified as one of the limiting factors for fast LHC turnaround time. The LHC Injection Quality Check (IQC) software framework was developed as a part of this thesis to monitor the beam quality...

  3. Outcome analysis of two different injection solutions for epidural injection in radicular lumbar backache syndromes

    International Nuclear Information System (INIS)

    Saqib, M.; Mukhtar, M.; Bhatti, S.N; Afridi, E.A.K.; Khan, R.

    2017-01-01

    Background: Backache is a significant source of disability and suffering in our society. The treatment modalities need continued enhancement in order to achieve the desired goals of lowering morbidity and financial losses while improving the response of the patient. Methods: This prospective comparative study was conducted at the department of Orthopaedics and Spine Surgery, Khyber Teaching Hospital Peshawar from July 2013 to June 2015. Two interventional groups were designated; Group 1 was comprised of 54 patients who were injected with epidural bupivacaine plus methylprednisolone while Group 2 included 55 patients who were injected with bupivacaine only. Outcome was assessed using the visual analogue scale and Oswestry disability index (ODI). Results: Fifty-five female and 54 male patients with mean age 49.37 years+-10.46 SD, Mean symptoms duration was 15.01 months+-9.32 SD. Common presenting symptoms were backache (77.1 percent), lower limbs pain (66.1 percent), dermatomal paresthesias (54.1 percent) and neurogenic claudication in 57.8 percent patients. The mean visual analogue score (VAS) after injection was 3.18+-1.29 while mean ODI after injection was 23.615. There was a statistically significant reduction in VAS scores (2-sided p=0.003, OR =4.03, 95 percent CI: 1.535-10.60) following the injection. Conclusion: An epidural spinal injection is a viable option for achieving relief of pain and improves functioning in individuals with radicular backache. However, further research is advised in order to clarify the role of ESI for long-term relief. (author)

  4. Long-Term Outcomes in Patients with Neovascular Age-Related Macular Degeneration Who Maintain Dry Macula after Three Monthly Ranibizumab Injections.

    Science.gov (United States)

    Kim, Kyung Min; Kim, Jae Hui; Chang, Young Suk; Kim, Jong Woo; Kim, Chul Gu

    2018-01-01

    To evaluate long-term changes in visual acuity and retinal microstructure in patients with neovascular age-related macular degeneration (AMD) who had maintained dry macula after initial treatment. This retrospective observational study included 55 eyes that were diagnosed with neovascular AMD, were treated with three monthly ranibizumab injections, and maintained dry macula during a two-year follow-up. Best-corrected visual acuity (BCVA) at three months and at the final follow-up were compared, and the degree of visual improvement was compared between eyes with and without improvement of the ellipsoid zone. In addition, the incidence of improvement of the ellipsoid zone was compared between eyes with different extents of disruption. The mean follow-up period was 30.3 ± 4.1 months. BCVA at three months and at the final follow-up was 0.51 ± 0.46 and 0.45 ± 0.49 (P200 μm of disruption of the ellipsoid zone, 15 (42.9%) showed improvement of the ellipsoid zone, and the improvement in BCVA was greater in these eyes than that in the remaining 20 eyes (P=0.021). A higher incidence of improvement of the ellipsoid zone was noted in eyes with 200 to 800 μm of disruption than in eyes with >800 μm of disruption (P<0.001). Long-term improvement in visual acuity was noted in eyes that had maintained dry macula after three ranibizumab injections. The status of the ellipsoid zone at three months was closely associated with visual improvement.

  5. OPTICALLY BASED CHARGE INJECTION SYSTEM FOR IONIZATION DETECTORS

    International Nuclear Information System (INIS)

    CHEN, H.; CITTERIO, M.; LANNI, F.; LEITE, M.A.L.; RADEKA, V.; RESCIA, S.; TAKAI, H.

    2001-01-01

    An optically coupled charge injection system for ionization based radiation detectors which allows a test charge to be injected without the creation of ground loops has been developed. An ionization like signal from an external source is brought into the detector through an optical fiber and injected into the electrodes by means of a photodiode. As an application example, crosstalk measurements on a liquid Argon electromagnetic calorimeter readout electrodes were performed

  6. Construction of a Direct Water-Injected Two-Stroke Engine for Phased Direct Fuel Injection-High Pressure Charging Investigations

    Science.gov (United States)

    Somsel, James P.

    1998-01-01

    The development of a water injected Orbital Combustion Process (OCP) engine was conducted to assess the viability of using the powerplant for high altitude NASA aircraft and General Aviation (GA) applications. An OCP direct fuel injected, 1.2 liter, three cylinder, two-stroke engine has been enhanced to independently inject water directly into the combustion chamber. The engine currently demonstrates low brake specific fuel consumption capability and an excellent power to weight ratio. With direct water injection, significant improvements can be made to engine power, to knock limits/ignition advance timing, and to engine NO(x) emissions. The principal aim of the testing was to validate a cyclic model developed by the Systems Analysis Branch at NASA Ames Research Center. The work is a continuation of Ames' investigations into a Phased Direct Fuel Injection Engine with High Pressure Charging (PDFI-ITPC).

  7. Construction and 60 kV tests of the prototype pulser for the LHC injection kicker system

    CERN Document Server

    Barnes, M J; Carlier, E; Ducimetière, L; Schröder, G; Vossenberg, Eugène B

    1999-01-01

    The European Laboratory for Particle Physics (CERN) is constructing the Large Hadron Collider (LHC). Two counter-rotating proton beams will be injected into the LHC at an energy of 450 GeV by two kicker magnet systems, producing magnetic field pulses of approximately 900 ns rise time and 6.6 mu s flat top duration with a ripple of less than +or-0.5Both injection systems are composed of 4 travelling wave kicker magnets of 2.17 m length each, powered by pulse forming networks (PFNs). To achieve the high-required kick strength of 1.2 Tm, for a compact and cost efficient design, a characteristic impedance of 5 Ohms has been chosen. The design strategy for the magnets and generators has been defined after detailed analysis of existing systems. The electrical circuit has been optimised using the circuit analysis software PSpice. Most known parasitics have been modelled. A prototype PFN has been constructed at CERN and successfully tested at 60 kV. A calibration procedure has been developed and utilised for obtainin...

  8. Safety and effectiveness of a single and repeat intramuscular injection of a GnRH vaccine (GonaCon™) in adult female domestic cats.

    Science.gov (United States)

    Vansandt, L M; Kutzler, M A; Fischer, A E; Morris, K N; Swanson, W F

    2017-04-01

    Sterilization is a key strategy to reduce the number of domestic cats entering and killed in shelters each year. However, surgical sterilization is expensive and labour-intensive and cannot fully address the 70 million free-roaming cats estimated to exist in the United States. GonaCon™ is a gonadotropin-releasing hormone vaccine originally developed for use as a wildlife immunocontraceptive. An earlier formulation was tested in domestic cats and found to be safe and effective for long-term contraception. However, the current Environmental Protection Agency (EPA)-registered formulation consists of a different antigen-carrier protein and increased antigen concentration and has never been tested in cats. A pilot study was undertaken to evaluate the short-term safety of a single GonaCon immunization, assess the consequences of vaccinated cats receiving an accidental second GonaCon injection and determine the humoral immune response to immunization. During Phase 1, cats in Group A (n = 3) received a single intramuscular injection of GonaCon and Group B (n = 3) received a single intramuscular injection of saline. During Phase 2, Group A received a second GonaCon injection and Group B received their initial GonaCon injection. All cats developed GnRH antibodies within 30 days of vaccine administration. The endpoint titre (1:1,024,000) was similar among all cats, and levels remained high throughout the duration of the study. Four cats developed a sterile, painless, self-limiting mass at the site of injection. The mean number of days to mass development was 110.3 (range, 18-249 days). In conclusion, this preliminary study suggests that the EPA-registered GonaCon formulation is safe for continued testing in domestic cats, an accidental revaccination should not increase the risk of a vaccine reaction and the EPA-registered formulation effectively elicits a strong humoral immune response. © 2016 Blackwell Verlag GmbH.

  9. The SSRL linacs for injection to the storage ring and rf gun testing

    International Nuclear Information System (INIS)

    Park, Sanghyun; Weaver, James N.

    1996-01-01

    The Stanford Synchrotron Radiation Laboratory (SSRL) operates two linac systems. One has three SLAC type linac sections powered by two klystrons for injection of electrons at 120 MeV into the booster ring, boosting the energy to 2.3 GeV to fill the SPEAR. After the ramping, the SPEAR stores up to 100 mA of the beam at 3.0 GeV. The preinjector consists of a thermionic RF gun, an alpha magnet, and a chopper along with focusing magnets. The other has one 10 foot section powered by the injector klystron for the testing of RF gun with photocathode, which is driven by a separate klystron. This paper describes present systems with their operational parameters, followed by plans for the upgrades and RF gun development efforts at the SSRL. (author)

  10. Policing behaviors, safe injection self-efficacy, and intervening on injection risks: Moderated mediation results from a randomized trial.

    Science.gov (United States)

    Pitpitan, Eileen V; Patterson, Thomas L; Abramovitz, Daniela; Vera, Alicia; Martinez, Gustavo; Staines, Hugo; Strathdee, Steffanie A

    2016-01-01

    We aim to use conditional or moderated mediation to simultaneously test how and for whom an injection risk intervention was efficacious at reducing receptive needle sharing among female sex workers who inject drugs (FSWs-IDUs) in Mexico. Secondary analysis of data from a randomized trial. A total of 300 FSW-IDUs participated in Mujer Mas Segura in Ciudad Juarez, Mexico, and were randomized to an interactive injection risk intervention or a didactic injection risk intervention. We measured safe injection self-efficacy as the hypothesized mediator and policing behaviors (being arrested and syringe confiscation) as hypothesized moderators. In total, 213 women provided complete data for the current analyses. Conditional (moderated) mediation showed that the intervention affected receptive needle sharing through safe injection self-efficacy among women who experienced syringe confiscation. On average, police syringe confiscation was associated with lower safe injection self-efficacy (p = .04). Among those who experienced syringe confiscation, those who received the interactive (vs. didactic) intervention reported higher self-efficacy, which in turn predicted lower receptive needle sharing (p = .04). Whereas syringe confiscation by the police negatively affected safe injection self-efficacy and ultimately injection risk behavior, our interactive intervention helped to "buffer" this negative impact of police behavior on risky injection practices. The theory-based, active skills building elements included in the interactive condition, which were absent from the didactic condition, helped participants' self-efficacy for safer injection in the face of syringe confiscation. (c) 2015 APA, all rights reserved).

  11. Experiments on the behaviour of thermite melt injected into sodium: Final report on the THINA test results

    International Nuclear Information System (INIS)

    Huber, F.; Kaiser, A.; Peppler, W.

    1994-01-01

    During hypothetical accidents of fast breeder reactors the core melts and part of the core material inventory is ejected into the upper coolant plenum. As a consequence, a fuel to coolant thermal interaction occurs between the melt and the sodium. A series of simulating experiments was carried out in KfK/IRS to improve the knowledge about the phenomenology of molten fuel/coolant interactions and to support theoretical work on the safety of fast breeder reactors. In the tests, a thermite melt of up to 3270 K is injected from below into a sodium pool the temperature of which is between 770 and 820 K. The masses of the melt and the sodium are about five and 150 kg, respectively. Thermal interactions have been observed to occur as a sequence of small local pressure events mainly during the melt injection. Large-scale vapour explosions have not been observed. Generally, the conversion ratios of thermal to mechanical energy have been low. (author)

  12. Using predictive uncertainty analysis to optimise tracer test design and data acquisition

    Science.gov (United States)

    Wallis, Ilka; Moore, Catherine; Post, Vincent; Wolf, Leif; Martens, Evelien; Prommer, Henning

    2014-07-01

    Tracer injection tests are regularly-used tools to identify and characterise flow and transport mechanisms in aquifers. Examples of practical applications are manifold and include, among others, managed aquifer recharge schemes, aquifer thermal energy storage systems and, increasingly important, the disposal of produced water from oil and shale gas wells. The hydrogeological and geochemical data collected during the injection tests are often employed to assess the potential impacts of injection on receptors such as drinking water wells and regularly serve as a basis for the development of conceptual and numerical models that underpin the prediction of potential impacts. As all field tracer injection tests impose substantial logistical and financial efforts, it is crucial to develop a solid a-priori understanding of the value of the various monitoring data to select monitoring strategies which provide the greatest return on investment. In this study, we demonstrate the ability of linear predictive uncertainty analysis (i.e. “data worth analysis”) to quantify the usefulness of different tracer types (bromide, temperature, methane and chloride as examples) and head measurements in the context of a field-scale aquifer injection trial of coal seam gas (CSG) co-produced water. Data worth was evaluated in terms of tracer type, in terms of tracer test design (e.g., injection rate, duration of test and the applied measurement frequency) and monitoring disposition to increase the reliability of injection impact assessments. This was followed by an uncertainty targeted Pareto analysis, which allowed the interdependencies of cost and predictive reliability for alternative monitoring campaigns to be compared directly. For the evaluated injection test, the data worth analysis assessed bromide as superior to head data and all other tracers during early sampling times. However, with time, chloride became a more suitable tracer to constrain simulations of physical transport

  13. Cross-border drug injection relationships among injection drug users in Tijuana, Mexico

    Science.gov (United States)

    Wagner, Karla D.; Pollini, Robin A.; Patterson, Thomas L.; Lozada, Remedios; Ojeda, Victoria D.; Brouwer, Kimberly C.; Vera, Alicia; Volkmann, Tyson A.; Strathdee, Steffanie A.

    2010-01-01

    Background International borders are unique social and environmental contexts characterized by high levels of mobility. Among drug users, mobility increases risk for human immunodeficiency virus (HIV) in part through its effects on the social environment. However, the social dynamics of drug users living in border regions are understudied. Methods 1056 injection drug users (IDUs) residing in Tijuana, Mexico were recruited using respondent-driven sampling (RDS) from 2006 to 2007, and underwent surveys and testing for HIV, syphilis, and tuberculosis (TB). Using logistic regression on baseline data, we identified correlates of having ever injected drugs with someone from the US. Results Almost half (48%) reported ever injecting drugs with someone from the US. In RDS-adjusted logistic regression, factors independently associated with having ever injected with someone from the US included: having greater than middle school education (Adjusted Odds Ratio [AOR] 2.91; 95% Confidence Interval [C.I.] 1.52, 5.91), speaking English (AOR 3.24, 95% C.I. 1.96, 5.36), age (AOR 1.10 per year; 95% C.I. 1.07, 1.14), age at initiation of injection drug use (AOR 0.90 per year; 95% C.I. 0.86, 0.94), homelessness (AOR 2.61; 95% C.I. 1.27, 5.39), and having ever been incarcerated (AOR 11.82; 95% C.I., 5.22, 26.77). No associations with HIV, syphilis, TB, drug use, or injection risk behavior were detected. Conclusion Findings suggest that IDU networks in Mexico and the US may transcend international borders, with implications for cross-border transmission of infectious disease. Binational programs and policies need to consider the structure and geographic distribution of drug using networks. PMID:20889270

  14. Temporal pore pressure induced stress changes during injection and depletion

    Science.gov (United States)

    Müller, Birgit; Heidbach, Oliver; Schilling, Frank; Fuchs, Karl; Röckel, Thomas

    2016-04-01

    Induced seismicity is observed during injection of fluids in oil, gas or geothermal wells as a rather immediate response close to the injection wells due to the often high-rate pressurization. It was recognized even earlier in connection with more moderate rate injection of fluid waste on a longer time frame but higher induced event magnitudes. Today, injection-related induced seismicity significantly increased the number of events with M>3 in the Mid U.S. However, induced seismicity is also observed during production of fluids and gas, even years after the onset of production. E.g. in the Groningen gas field production was required to be reduced due to the increase in felt and damaging seismicity after more than 50 years of exploitation of that field. Thus, injection and production induced seismicity can cause severe impact in terms of hazard but also on economic measures. In order to understand the different onset times of induced seismicity we built a generic model to quantify the role of poro-elasticity processes with special emphasis on the factors time, regional crustal stress conditions and fault parameters for three case studies (injection into a low permeable crystalline rock, hydrothermal circulation and production of fluids). With this approach we consider the spatial and temporal variation of reservoir stress paths, the "early" injection-related induced events during stimulation and the "late" production induced ones. Furthermore, in dependence of the undisturbed in situ stress field conditions the stress tensor can change significantly due to injection and long-term production with changes of the tectonic stress regime in which previously not critically stressed faults could turn to be optimally oriented for fault reactivation.

  15. An Evaluation of the Carbon Sequestration Potential of the Cambro-Ordovician Strata of the Illinois and Michigan Basins. Part 1. Evaluation of Phase 2 CO2 Injection Testing in the Deep Saline Gunter Sandstone Reservoir (Cambro-Ordovician Knox Group), Marvin Blan No. 1 Hancock County, Kentucky Part 2. Time-lapse Three-Dimensional Vertical Seismic Profile (3D-VSP) of Sequestration Target Interval with Injected Fluids

    Energy Technology Data Exchange (ETDEWEB)

    Bowersox, Richard [Univ. of Illinois, Champaign, IL (United States); Hickman, John [Univ. of Illinois, Champaign, IL (United States); Leetaru, Hannes [Univ. of Illinois, Champaign, IL (United States)

    2012-12-20

    Part 1 of this report focuses on results of the western Kentucky carbon storage test, and provides a basis for evaluating injection and storage of supercritical CO2 in Cambro-Ordovician carbonate reservoirs throughout the U.S. Midcontinent. This test demonstrated that the Cambro- Ordovician Knox Group, including the Beekmantown Dolomite, Gunter Sandstone, and Copper Ridge Dolomite in stratigraphic succession from shallowest to deepest, had reservoir properties suitable for supercritical CO2 storage in a deep saline reservoir hosted in carbonate rocks, and that strata with properties sufficient for long-term confinement of supercritical CO2 were present in the deep subsurface. Injection testing with brine and CO2 was completed in two phases. The first phase, a joint project by the Kentucky Geological Survey and the Western Kentucky Carbon Storage Foundation, drilled the Marvin Blan No. 1 carbon storage research well and tested the entire Knox Group section in the open borehole – including the Beekmantown Dolomite, Gunter Sandstone, and Copper Ridge Dolomite – at 1152–2255 m, below casing cemented at 1116 m. During Phase 1 injection testing, most of the 297 tonnes of supercritical CO2 was displaced into porous and permeable sections of the lowermost Beekmantown below 1463 m and Gunter. The wellbore was then temporarily abandoned with a retrievable bridge plug in casing at 1105 m and two downhole pressure-temperature monitoring gauges below the bridge plug pending subsequent testing. Pressure and temperature data were recorded every minute for slightly more than a year, providing a unique record of subsurface reservoir conditions in the Knox. In contrast, Phase 2 testing, this study, tested a mechanically-isolated dolomitic-sandstone interval in the Gunter.

  16. Verification of zinc injection applicability to Japanese BWRs

    International Nuclear Information System (INIS)

    Hosokawa, H.; Uetake, N.; Ishida, K.; Nakamura, M.; Mochizuki, K.; Nagata, T.; Ogawa, N.; Baba, T.; Ono, S.; Ishigure, K.

    2002-01-01

    The verification test program on zinc injection applicability to Japanese BWRs was started in 1997. Laboratory tests using high temperature water loops under BWR reactor water conditions are in progress. This paper is an interim report on results obtained so far. Co-58 and Zn-65 were simultaneously used in the Co radioactivity buildup test to evaluate zinc injection suppression effects towards cobalt deposition on pre-oxidized stainless steel. The following results were obtained. The Co deposition was suppressed effectively by Zn injection, even when there was a pre-oxide film. For the test piping that had the pre-oxide film formed under the NWC (normal water chemistry) condition, when soaked under the HWC (hydrogen water chemistry) condition a large amount of Co-58 was taken into a small part of the inner layer. The distribution ratio of Co-58 in the inner layer and outer layer of the oxide film was almost the same for both the pre-oxidized test piping and the non pre-oxidized test piping under the HWC condition. Zn injection decreased the Co concentration in the inner layer of the oxide film under all conditions. The effect of gamma ray irradiation on the incorporation of Co into the oxide film is small. Gamma ray irradiation influenced the Co incorporation behavior complexly. The change of the Co amount incorporated into the non-pre-filmed specimen were small relatively, but the incorporation into the pre-filmed specimen promotes distinctly. Zn addition effectively suppresses the Co incorporation even gamma ray irradiation. (authors)

  17. Two-dimensional thermal-hydraulic behavior in core in SCTF Core-II cold leg injection tests

    International Nuclear Information System (INIS)

    Iwamura, Takamichi; Sobajima, Makoto; Okubo, Tsutomu; Ohnuki, Akira; Abe, Yutaka; Adachi, Hiromichi

    1985-07-01

    Major purpose of the Slab Core Test Program is to investigate the two-dimensional thermal-hydraulic behavior in the core during the reflood phase in a PWR-LOCA. In order to investigate the effects of radial power profile, three cold leg injection tests with different radial power profiles under the same total heating power and core stored energy were performed by using the Slab Core Test Facility (SCTF) Core-II. It was revealed by comparing these three tests that the heat transfer was enhanced in the higher power bundles and degraded in the lower power bundles in the non-uniform radial power profile tests. The turnaround temperature in the high power bundles were evaluated to be reduced by about 40 to 120 K. On the other hand, a two-dimensional flow in the core was also induced by the non-uniform water accumulation in the upper plenum and the quench was delayed resultantly in the bundles corresponding to the peripheral bundles of a PWR. However, the effect of the non-uniform upper plenum water accumulation on the turnaround temperature was small because the effect dominated after the turnaround of the cladding temperature. Selected data from Tests S2-SH1, S2-SH2 and S2-O6 are also presented in this report. Some data from Tests S2-SH1 and S2-SH2 were compared with TRAC post-test calculations performed by the Los Alamos National Laboratory. (author)

  18. Quasi-stable injection channels in a wakefield accelerator

    CERN Document Server

    Wiltshire-Turkay, Mara; Pukhov, Alexander

    2016-01-01

    Particle-driven plasma-wakefield acceleration is a promising alternative to conventional electron acceleration techniques, potentially allowing electron acceleration to energies orders of magnitude higher than can currently be achieved. In this work we investigate the dependence of the energy gain on the position at which electrons are injected into the wake. Test particle simulations show previously unobserved complex structure in the parameter space, with quasi-stable injection channels forming for particles injected in narrow regions away from the centre of the wake. The result is relevant to the planning and tuning of experiments making use of external injection.

  19. Preliminary test conditions for KNGR SBLOCA DVI ECCS performance test

    International Nuclear Information System (INIS)

    Bae, Kyoo Whan; Song, Jin Ho; Chung, Young Jong; Sim, Suk Ku; Park, Jong Kyun

    1999-03-01

    The Korean Next Generation Reactor (KNGR) adopts 4-train Direct Vessel Injection (DVI) configuration and injects the safety injection water directly into the downcomer through the 8.5'' DVI nozzle. Thus, the thermal hydraulic phenomena such as ECCS mixing and bypass are expected to be different from those observed in the cold leg injection. In order to investigate the realistic injection phenomena and modify the analysis code developed in the basis of cold leg injection, thermal hydraulic test with the performance evaluation is required. Preliminarily, the sequence of events and major thermal hydraulic phenomena during the small break LOCA for KNGR are identified from the analysis results calculated by the CEFLASH-4AS/REM. It is shown from the analysis results that the major transient behaviors including the core mixture level are largely affected by the downcomer modeling. Therefore, to investigate the proper thermal hydraulic phenomena occurring in the downcomer with limited budget and time, the separate effects test focusing on this region is considered to be effective and the conceptual test facility based on this recommended. For this test facility the test initial and boundary conditions are developed using the CEFLASH-4AS/REM analysis results that will be used as input for the preliminary test requirements. The final test requirements will be developed through the further discussions with the test performance group. (Author). 10 refs., 18 tabs., 4 figs

  20. Media-fill simulation tests in manual and robotic aseptic preparation of injection solutions in syringes.

    Science.gov (United States)

    Krämer, Irene; Federici, Matteo; Kaiser, Vanessa; Thiesen, Judith

    2016-04-01

    The purpose of this study was to evaluate the contamination rate of media-fill products either prepared automated with a robotic system (APOTECAchemo™) or prepared manually at cytotoxic workbenches in the same cleanroom environment and by experienced operators. Media fills were completed by microbiological environmental control in the critical zones and used to validate the cleaning and disinfection procedures of the robotic system. The aseptic preparation of patient individual ready-to-use injection solutions was simulated by using double concentrated tryptic soy broth as growth medium, water for injection and plastic syringes as primary packaging materials. Media fills were either prepared automated (500 units) in the robot or manually (500 units) in cytotoxic workbenches in the same cleanroom over a period of 18 working days. The test solutions were incubated at room temperature (22℃) over 4 weeks. Products were visually inspected for turbidity after a 2-week and 4-week period. Following incubation, growth promotion tests were performed with Staphylococcus epidermidis. During the media-fill procedures, passive air monitoring was performed with settle plates and surface monitoring with contact plates on predefined locations as well as fingerprints. The plates got incubated for 5-7 days at room temperature, followed by 2-3 days at 30-35℃ and the colony forming units (cfu) counted after both periods. The robot was cleaned and disinfected according to the established standard operating procedure on two working days prior to the media-fill session, while on six other working days only six critical components were sanitized at the end of the media-fill sessions. Every day UV irradiation was operated for 4 h after finishing work. None of the 1000 media-fill products prepared in the two different settings showed turbidity after the incubation period thereby indicating no contamination with microorganisms. All products remained uniform, clear, and light

  1. Durability 2007. Injection grout investigations. Background description

    International Nuclear Information System (INIS)

    Orantie, K.; Kuosa, H.

    2008-12-01

    The aim of this project was to evaluate the durability risks of injection grouts. The investigations were done with respect to the application conditions, materials and service life requirements at the ONKALO underground research facility. The study encompassed injection grout mixtures made of ultrafine cement with and without silica fume. Some of the mixtures hade a low pH and thus a high silica fume content. The project includes a background description on durability literature, laboratory testing programme, detailed analysis of results and recommendations for selecting of ideal grout mixtures. The background description was made for the experimental study of low-pH and reference rock injection grouts as regards pore- and microstructure, strength, shrinkage/swelling and thus versatile durability properties. A summary of test methods is presented as well as examples, i.e. literature information or former test results, of expected range of results from the tests. Also background information about how the test results correlate to other material properties and mix designs is presented. Besides the report provides basic information on the pore structure of cement based materials. Also the correlation between the pore structure of cement based materials and permeability is shortly discussed. The test methods included in the background description are compressive strength, measurement of bulk drying, autogenous and chemical shrinkage and swelling, hydraulic conductivity / permeability, capillary water uptake test, mercury intrusion porosimetry (MIP) and thin section analysis. Three main mixtures with water-binder ratio of 0.8, 1.0 and 1.4 and silica fume content of 0, 15 and 40% were studied in the laboratory. Besides two extra mixtures were studied to provide additional information about the effect of varying water-dry-material ratio and silica fume content on durability. The evaluation of water tightness based on water permeability coefficient and micro cracking was

  2. Short term mutagenicity tests and their application to irradiated foods

    International Nuclear Information System (INIS)

    Phillips, B.J.; Elias, P.S.

    1980-01-01

    Although traditional long-term animal tests are likely to continue to be required, these are not only extremely costly but are coming more and more to be recognised as an imprecise and unsatisfactory method of testing the safety of irradiated foods for human consumption. It is therefore clearly advisable to include a selection of quicker and more direct testing methods in any toxicological assessment procedures. The International Project has therefore undertaken a study of the feasibility of using the newer systems for investigation of irradiated foodstuffs. Although some work in this field has already been carried out, some shortcomings in the published work can be identified which justify a more detailed and intensive research programme. As expected, little difficulty has been encountered in testing food by methods involving mammals, but considerable effort has been required to adapt in vitro systems. The use of enzymatic digestion in vitro to provide food samples for testing in mammalian cell cultures has never been attempted before and the procedures developed by the Project represent a positive contribution to methodology in this field. A series of foodstuffs is being tested by a wide spectrum of short-term tests and the first results are now being obtained. (orig./MG) [de

  3. Diesel injector dynamic modelling and estimation of injection parameters from impact response part 2: prediction of injection parameters from monitored vibration

    OpenAIRE

    Gu, Fengshou; Ball, Andrew; Rao, K K

    1996-01-01

    Part 2 of this paper presents the experimental and analytical procedures used in the estimation of injection parameters from monitored vibration. The mechanical and flow‐induced sources of vibration in a fuel injector are detailed and the features of the resulting vibration response of the injector body are discussed. Experimental engine test and data acquisition procedures are described, and the use of an out‐of‐the‐engine test facility to confirm injection dependent vibration response is ou...

  4. Resveratrol Ameliorates the Depressive-Like Behaviors and Metabolic Abnormalities Induced by Chronic Corticosterone Injection

    Directory of Open Access Journals (Sweden)

    Yu-Cheng Li

    2016-10-01

    Full Text Available Chronic glucocorticoid exposure is known to cause depression and metabolic disorders. It is critical to improve abnormal metabolic status as well as depressive-like behaviors in patients with long-term glucocorticoid therapy. This study aimed to investigate the effects of resveratrol on the depressive-like behaviors and metabolic abnormalities induced by chronic corticosterone injection. Male ICR mice were administrated corticosterone (40 mg/kg by subcutaneous injection for three weeks. Resveratrol (50 and 100 mg/kg, fluoxetine (20 mg/kg and pioglitazone (10 mg/kg were given by oral gavage 30 min prior to corticosterone administration. The behavioral tests showed that resveratrol significantly reversed the depressive-like behaviors induced by corticosterone, including the reduced sucrose preference and increased immobility time in the forced swimming test. Moreover, resveratrol also increased the secretion of insulin, reduced serum level of glucose and improved blood lipid profiles in corticosterone-treated mice without affecting normal mice. However, fluoxetine only reverse depressive-like behaviors, and pioglitazone only prevent the dyslipidemia induced by corticosterone. Furthermore, resveratrol and pioglitazone decreased serum level of glucagon and corticosterone. The present results indicated that resveratrol can ameliorate depressive-like behaviors and metabolic abnormalities induced by corticosterone, which suggested that the multiple effects of resveratrol could be beneficial for patients with depression and/or metabolic syndrome associated with long-term glucocorticoid therapy.

  5. Pool scrubbing and hydrodynamic experiments on jet injection regime

    International Nuclear Information System (INIS)

    Peyres, V.; Espigares, M.M.; Polo, J.; Escudero, M.J.; Herranz, L.E.; Lopez-Jimenez, J.

    1995-01-01

    Plant analyses have shown that pool scrubbing can play an important role in source term during PWR risk dominant sequences. An examination ofboundary conditions governing fission products and aerosols transport through aqueous beds revealed that most of radioactivity is discharged into the pool under jet injection regime. This fact and the lack of experimental data under such conditions pointed the need of setting out an experimental programme which provided reliable experimental data to validate code models. In this report the major results of a pool scrubbing experimental programme carried out in PECA facility are presented. One of the major findings was that a remarkable fraction of particle absorption was not a function of the residence time of bubbles rising through the pool. Such a contribution was assumed to be associated to aerosol removal mechanisms acting at the pool entrance. As a consequence, a hydrodynamic experimental plan was launched to examine the gas behaviour during the initial stages in the pool. Size and shape of gas nuclei the pool were measured and fitted to a long normal distribution. Particularly, size was found to be quite sensitive to inletgas flow and at minor extent to gas composition and pool temperature. SPARC90 and BUSCA-AUG92 were used to simulate the retention tests. Whereas SPARC90 showed a pretty good agreement with experimental data, BUSCA-AUG92 results were far away from measurements in all the cases. SPARC90consistency apparently pointed out the important role of fission products and aerosols retention at the injection zone; nonetheless, a peer examination of pool scrubbing phenomenology at the pool entrance should be carried out to test both hydrodynamic and removal models. Hence, one of the major highlights drawn from this work was the need of further research under representative severe accident conditions (i.e., saturated pools, jet injection regimes, etc.), as well as separate effect tests to validate, improve and

  6. Pool scrubbing and hydrodynamic experiment on jet injection regime

    Energy Technology Data Exchange (ETDEWEB)

    Peyres, V.; Espigares, M.M.; Polo, J.; Escudero, M.J.; Herranz, L.E.; Lopez, J.

    1995-07-01

    Plant analyses nave shown that pool scrubbing can play an important role in source term during PWR risk dominant sequences. An examination of boundary conditions governing fission products and aerosols transport through aqueous beds revealed that most of radioactivity is discharged into the pool under jet injection regime. This fact and the lack of experimental data under such conditions pointed the need of setting out an experimental programme which provided reliable experimental data to validate code models. In this report the major results of a pool scrubbing experimental programme carried out in PECA facility are presented. One of the major findings was that a remarkable fraction of particle absorption was not a function of the residence time of bubbles rising through the pool. Such a contribution was assumed to be associated to aerosol removal mechanism acting at the pool entrance. As a consequence. a hydrodynamic experimental plan was launched to examine the gas behaviour during the initial stages in the pool. Size and shape of gas nuclei in the pool were measured and fitted to a lognormal distribution. Particularly, size was found to be quite sensitive to inlet gas flow and at minor extent to gas composition and pool temperature. SPARC90 and BUSCA-AUG92 were used to simulate the retention tests. Whereas SPARC90 showed a pretty good agreement with experimental data, BUSCA-AUG92 results were far away from measurements in all the cases. SPARC90 consistency apparently pointed out the important role of fission products and aerosols retention at the injection zone; nonetheless, a peer examination of pool scrubbing phenomenology at the pool entrance should be carried out to test both hydrodynamic and removal models. Hence, one of the major high lights drawn from this work was the need of further research under representative severe accident conditions (i.e., saturated pools, jet injection regimes, etc.), as well as separate effect tests to validate, improve and

  7. Pool scrubbing and hydrodynamic experiment on jet injection regime

    International Nuclear Information System (INIS)

    Peyres, V.; Espigares, M.M.; Polo, J.; Escudero, M.J.; Herranz, L.E.; Lopez, J.

    1995-01-01

    Plant analyses nave shown that pool scrubbing can play an important role in source term during PWR risk dominant sequences. An examination of boundary conditions governing fission products and aerosols transport through aqueous beds revealed that most of radioactivity is discharged into the pool under jet injection regime. This fact and the lack of experimental data under such conditions pointed the need of setting out an experimental programme which provided reliable experimental data to validate code models. In this report the major results of a pool scrubbing experimental programme carried out in PECA facility are presented. One of the major findings was that a remarkable fraction of particle absorption was not a function of the residence time of bubbles rising through the pool. Such a contribution was assumed to be associated to aerosol removal mechanism acting at the pool entrance. As a consequence. a hydrodynamic experimental plan was launched to examine the gas behaviour during the initial stages in the pool. Size and shape of gas nuclei in the pool were measured and fitted to a lognormal distribution. Particularly, size was found to be quite sensitive to inlet gas flow and at minor extent to gas composition and pool temperature. SPARC90 and BUSCA-AUG92 were used to simulate the retention tests. Whereas SPARC90 showed a pretty good agreement with experimental data, BUSCA-AUG92 results were far away from measurements in all the cases. SPARC90 consistency apparently pointed out the important role of fission products and aerosols retention at the injection zone; nonetheless, a peer examination of pool scrubbing phenomenology at the pool entrance should be carried out to test both hydrodynamic and removal models. Hence, one of the major high lights drawn from this work was the need of further research under representative severe accident conditions (i.e., saturated pools, jet injection regimes, etc.), as well as separate effect tests to validate, improve and

  8. Microwave freeze-thaw technique of injectable drugs. A review from 1980 to 2014.

    Science.gov (United States)

    Hecq, J-D; Godet, M; Jamart, J; Galanti, L

    2015-11-01

    Microwave freeze-thaw treatment (MFTT) of injectable drugs can support the development of centralized intravenous admixtures services (CIVAS). The aim of the review is to collect information and results about this method. A systematic review of the scientific literature about injectable drug stability studies was performed. The data are presented in a table and describe name of the drug, producer, final concentration, temperature and time of freezing storage, type of microwave oven, thawing power, method of dosage and results after treatment or final long-term storage at 5±3 °C. From 1980 to 2014, 59 drugs were studied by MFTT and the results were presented in 49 publications. Forty papers were presented by 8 teams (2 to 18 by team). The temperatures of freezing storage vary from -70 °C to -10 °C, the time storage from 4 hours to 12 months, the thaw from low to full power. Dosages are mainly made by high performance liquid chromatography. Most of the 59 drugs are stable during and after treatment. Only 3 teams have tested the long-term stability after MFTT, the first for ganciclovir after 7 days, the second for ceftizoxime after 30 days and the third for 19 drugs after 11 to 70 days. This review can help CIVAS to take in charge the productions of ready-to-use injectable drugs. Copyright © 2015 Académie Nationale de Pharmacie. Published by Elsevier Masson SAS. All rights reserved.

  9. The association between neighborhood socioeconomic disadvantage and high-risk injection behavior among people who inject drugs.

    Science.gov (United States)

    DeCuir, Jennifer; Lovasi, Gina S; El-Sayed, Abdulrahman; Lewis, Crystal Fuller

    2018-02-01

    Although much research has been conducted on the determinants of HIV risk behavior among people who inject drugs (PWID), the influence of the neighborhood context on high-risk injection behavior remains understudied. To address this gap in the literature, we measured associations between neighborhood socioeconomic disadvantage and high-risk injection behavior, and determined whether these associations were modified by drug-related police activity and syringe exchange program (SEP) accessibility. Our sample was comprised of 484 pharmacy-recruited PWID in New York City. Measures of neighborhood socioeconomic disadvantage were created using data from the 2006-2010 American Community Survey. Associations with high-risk injection behavior were estimated using multivariable Poisson regression. Effect modification by drug-related police activity and SEP accessibility was assessed by entering cross-product terms into adjusted models of high-risk injection behavior. Neighborhood socioeconomic disadvantage was associated with decreased receptive syringe sharing and unsterile syringe use. In neighborhoods with high drug-related police activity, associations between neighborhood disadvantage and unsterile syringe use were attenuated to the null. In neighborhoods with high SEP accessibility, neighborhood disadvantage was associated with decreased acquisition of syringes from an unsafe source. PWID in disadvantaged neighborhoods reported safer injection behaviors than their counterparts in neighborhoods that were relatively better off. The contrasting patterns of effect modification by SEP accessibility and drug-related police activity support the use of harm reduction approaches over law enforcement-based strategies for the control of blood borne virus transmission among PWID in disadvantaged urban areas. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Mechanical Weakening during Fluid Injection in Critically Stressed Sandstones with Acoustic Monitoring

    Science.gov (United States)

    David, C.; Dautriat, J. D.; Sarout, J.; Macault, R.; Bertauld, D.

    2014-12-01

    Water weakening is a well-known phenomenon which can lead to subsidence during the production of hydrocarbon reservoirs. The example of the Ekofisk oil field in the North Sea has been well documented for years. In order to assess water weakening effects in reservoir rocks, previous studies have focused on changes in the failure envelopes derived from mechanical tests conducted on rocks saturated either with water or with inert fluids. However, little attention has been paid so far on the mechanical behaviour during the fluid injection stage, like in enhanced oil recovery operations. We studied the effect of fluid injection on the mechanical behaviour of Sherwood sandstone, a weakly-consolidated sandstone sampled at Ladram Bay in UK. In order to highlight possible weakening effects, water and inert oil have been injected into critically-loaded samples to assess their effect on strength and elastic properties and to derive the acoustic signature of the saturation front for each fluid. The specimens were instrumented with 16 ultrasonic P-wave transducers for both passive and active acoustic monitoring during fluid injection and loading. After conducting standard triaxial tests on three samples saturated with air, water and oil respectively, mechanical creep tests were conducted on dry samples loaded at 80% of the compressive strength of the dry rock. While these conditions are kept constant, a fluid is injected at the bottom end of the sample with a low back pressure (0.5 MPa) to minimize effective stress variations during injection. Both water and oil were used as the injected pore fluid in two experiments. As soon as the fluids start to flow into the samples, creep is taking place with a much higher strain rate for water injection compared to oil injection. A transition from secondary creep to tertiary creep is observed in the water injection test whereas in the oil injection test no significant creep acceleration is observed after one pore volume of oil was

  11. Lance water injection tests adjacent to the 281-3H retention basin at the Savannah River Site, Aiken, South Carolina

    International Nuclear Information System (INIS)

    Freifeld, B.; Myer, L.; Moridis, G.; Cook, P.; James, A.; Pellerin, L.; Pruess, K.

    1996-09-01

    A pilot-scale field demonstration of waste isolation using viscous- liquid containment barriers has been planned for the 281-3H retention basin at the Savannah River Site, Aiken, SC. The 281-3H basin is a shallow retention/seepage basin contaminated mainly by radionuclides. The viscous-liquid containment barrier utilizes the permeation of liquid grout to either entomb the contaminants within a monolithic grout structure or to isolate the waste by drastically reducing the permeability, of the soils around the plume. A clear understanding of the hydrogeologic setting of the retention basin is necessary for proper design of the viscous liquid barrier. To aid in the understanding of the hydrogeology of the 281-3H retention basin, and to obtain critical parameters necessary for grout injection design, a series of tests were undertaken in a region immediately adjacent to the basin. The objectives of the LWIT were: 1. To evaluate the general performance of the Lance Injection Technique for grout emplacement at the site, including the range and upper limits of injection pressures, the flow rates applicable for site conditions, as well as the mechanical forces needed for lance penetration. 2. To obtain detailed information on the injectability of the soils immediately adjacent to the H-area retention basin. 3. To identify any high permeability zones suitable for injection and evaluate their spatial distribution. 4. To perform ground penetrating radar (GPR) to gain information on the structure of the soil column and to compare the results with LWIT data. This report will focus on results pertinent to these objectives

  12. Safety assessment of the SMART design during SBLOCA tests using the high pressure safety injection pump of the SMART-ITL facility

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Hwang; Ryu, Sung Uk; Jeon, Byong-Guk; Yang, Jin-Hwa; Yoon, Eun-Koo; Shin, Yong-Cheol; Min, Kyoung-Ho; Park, Jong-Kuk; Choi, Nam-Hyun; Bang, Yun-Gon; Seo, Chan-Jong; Yi, Sung-Jae; Park, Hyun-Sik [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    SMART is a small-sized integral pressurized light water reactor designed by the Korea Atomic Energy Research Institute (KAERI) from 1997 and received standard design approval (SDA) by the Korean regulatory body in July 2012. Single reactor pressure vessel contains all of the main components including a pressurizer (PZR), steam generators (SG) and reactor coolant pumps (RCP) without any large-size pipes. Several tests to verify a safety and performance of SMART design were carried out. This paper introduces a comparison with three SBLOCA tests. Overall thermal-hydraulic phenomena were observed and showed a traditional trend to decrease a system pressure and temperature. A collapsed water level of the hot side indicated that the safety injection system was successfully operated to recover the reactor coolant system (RCS) and protect the core uncover. An SBLOCA test simulating a guillotine break on the SIS, SCS, and PSV was performed. It was enough to keep a steady-state condition before the SBLOCA test begins. An actuation signal as the boundary condition was properly simulated during the transient test. The scenarios of the SBLOCA in the SMART design were reproduced well using the SMART-ITL facility. The safety injection is effective to protect the core uncover as well as to cool down the RCS. All of the measured parameters show reasonable behaviors.

  13. Safety assessment of the SMART design during SBLOCA tests using the high pressure safety injection pump of the SMART-ITL facility

    International Nuclear Information System (INIS)

    Bae, Hwang; Ryu, Sung Uk; Jeon, Byong-Guk; Yang, Jin-Hwa; Yoon, Eun-Koo; Shin, Yong-Cheol; Min, Kyoung-Ho; Park, Jong-Kuk; Choi, Nam-Hyun; Bang, Yun-Gon; Seo, Chan-Jong; Yi, Sung-Jae; Park, Hyun-Sik

    2016-01-01

    SMART is a small-sized integral pressurized light water reactor designed by the Korea Atomic Energy Research Institute (KAERI) from 1997 and received standard design approval (SDA) by the Korean regulatory body in July 2012. Single reactor pressure vessel contains all of the main components including a pressurizer (PZR), steam generators (SG) and reactor coolant pumps (RCP) without any large-size pipes. Several tests to verify a safety and performance of SMART design were carried out. This paper introduces a comparison with three SBLOCA tests. Overall thermal-hydraulic phenomena were observed and showed a traditional trend to decrease a system pressure and temperature. A collapsed water level of the hot side indicated that the safety injection system was successfully operated to recover the reactor coolant system (RCS) and protect the core uncover. An SBLOCA test simulating a guillotine break on the SIS, SCS, and PSV was performed. It was enough to keep a steady-state condition before the SBLOCA test begins. An actuation signal as the boundary condition was properly simulated during the transient test. The scenarios of the SBLOCA in the SMART design were reproduced well using the SMART-ITL facility. The safety injection is effective to protect the core uncover as well as to cool down the RCS. All of the measured parameters show reasonable behaviors

  14. Development and characterisation of injection moulded, all-polypropylene composites

    Directory of Open Access Journals (Sweden)

    A. Kmetty

    2013-02-01

    Full Text Available In this work, all-polypropylene composites (all-PP composites were manufactured by injection moulding. Prior to injection moulding, pre-impregnated pellets were prepared by a three-step process (filament winding, compression moulding and pelletizing. A highly oriented polypropylene multifilament was used as the reinforcement material, and a random polypropylene copolymer (with ethylene was used as the matrix material. Plaque specimens were injection moulded from the pellets with either a film gate or a fan gate. The compression moulded sheets and injection moulding plaques were characterised by shrinkage tests, static tensile tests, dynamic mechanical analysis and falling weight impact tests; the fibre distribution and fibre/matrix adhesion were analysed with light microscopy and scanning electron microscopy. The results showed that with increasing fibre content, both the yield stress and the perforation energy significantly increased. Of the two types of gates used, the fan gate caused the mechanical properties of the plaque specimens to become more homogeneous (i.e., the differences in behaviour parallel and perpendicular to the flow direction became negligible.

  15. Detection of intramyocardially injected DiR-labeled mesenchymal stem cells by optical and optoacoustic tomography.

    Science.gov (United States)

    Berninger, Markus T; Mohajerani, Pouyan; Wildgruber, Moritz; Beziere, Nicolas; Kimm, Melanie A; Ma, Xiaopeng; Haller, Bernhard; Fleming, Megan J; Vogt, Stephan; Anton, Martina; Imhoff, Andreas B; Ntziachristos, Vasilis; Meier, Reinhard; Henning, Tobias D

    2017-06-01

    The distribution of intramyocardially injected rabbit MSCs, labeled with the near-infrared dye 1,1'-dioctadecyl-3,3,3',3'-tetramethylindotricarbo-cyanine-iodide (DiR) using hybrid Fluorescence Molecular Tomography-X-ray Computed Tomography (FMT-XCT) and Multispectral Optoacoustic Tomography (MSOT) imaging technologies, was investigated. Viability and induction of apoptosis of DiR labeled MSCs were assessed by XTT- and Caspase-3/-7-testing in vitro . 2 × 10 6 , 2 × 10 5 and 2 × 10 4 MSCs labeled with 5 and 10 μg DiR/ml were injected into fresh frozen rabbit hearts. FMT-XCT, MSOT and fluorescence cryosection imaging were performed. Concentrations up to 10 μg DiR/ml did not cause apoptosis in vitro (p > 0.05). FMT and MSOT imaging of labeled MSCs led to a strong signal. The imaging modalities highlighted a difference in cell distribution and concentration correlated to the number of injected cells. Ex-vivo cryosectioning confirmed the molecular fluorescence signal. FMT and MSOT are sensitive imaging techniques offering high-anatomic resolution in terms of detection and distribution of intramyocardially injected stem cells in a rabbit model.

  16. Risperidone long-acting injection: a review of its long term safety and efficacy

    Directory of Open Access Journals (Sweden)

    Michael K Rainer

    2008-08-01

    Full Text Available Michael K RainerMemory-Clinic and Psychiatric Department, Donauspital, Vienna, AustriaAbstract: A long-acting form of the second-generation antipsychotic drug risperidone is now broadly available for the treatment of schizophrenia and closely related psychiatric conditions. It combines the advantage of previously available depot formulations for first-generation drugs with the favorable characteristics of the modern “atypical” antipsychotics, namely higher efficacy in the treatment of the negative symptoms of schizophrenia and reduced motor disturbances. Published clinical studies show an objective clinical efficacy (as per psychiatric symptom scores and relapse data that exceeds that of oral atypical antipsychotics when patients are switched to the long-acting injectable form, a low incidence of treatment-emergent extrapyramidal side effects, and very good acceptance by patients. Available data for maintenance treatment of bipolar disorder show equivalence with the oral form instead of superiority, but are still limited. As it seems likely that efficacy benefits are mostly due to the fact that the injectable form reduces the demand for patient compliance to one physician visit every 2 weeks instead of self-administration on a daily or twice-daily basis, additional potential could exist in other psychiatric disorders where atypical antipsychotic drugs are of benefit but where patient adherence to treatment schedules is typically low.Keywords: risperidone, schizophrenia, psychotic disorders, patient compliance; delayed-action preparations, injections, intramuscular

  17. In vitro pyrogen test for toxic or immunomodulatory drugs

    OpenAIRE

    Daneshian, Mardas; Guenther, Armin; Wendel, Albrecht; Hartung, Thomas; Aulock, Sonja von

    2006-01-01

    Pyrogenic contaminations of some classes of injectable drugs, e.g. toxic or immunomodulatory as well as false-positive drugs, represent a major risk which cannot yet be excluded due to the limitations of current tests. Here we describe a modification of the In vitro Pyrogen Test termed AWIPT (Adsorb, Wash, In vitro Pyrogen Test), which addresses this problem by introducing a pre-incubation step in which pyrogenic contaminations in the test sample are adsorbed to albumin-coated beads. After ri...

  18. Dependability validation by means of fault injection: method, implementation, application

    International Nuclear Information System (INIS)

    Arlat, Jean

    1990-01-01

    This dissertation presents theoretical and practical results concerning the use of fault injection as a means for testing fault tolerance in the framework of the experimental dependability validation of computer systems. The dissertation first presents the state-of-the-art of published work on fault injection, encompassing both hardware (fault simulation, physical fault Injection) and software (mutation testing) issues. Next, the major attributes of fault injection (faults and their activation, experimental readouts and measures, are characterized taking into account: i) the abstraction levels used to represent the system during the various phases of its development (analytical, empirical and physical models), and Il) the validation objectives (verification and evaluation). An evaluation method is subsequently proposed that combines the analytical modeling approaches (Monte Carlo Simulations, closed-form expressions. Markov chains) used for the representation of the fault occurrence process and the experimental fault Injection approaches (fault Simulation and physical injection); characterizing the error processing and fault treatment provided by the fault tolerance mechanisms. An experimental tool - MESSALINE - is then defined and presented. This tool enables physical faults to be Injected In an hardware and software prototype of the system to be validated. Finally, the application of MESSALINE for testing two fault-tolerant systems possessing very dissimilar features and the utilization of the experimental results obtained - both as design feedbacks and for dependability measures evaluation - are used to illustrate the relevance of the method. (author) [fr

  19. Carbon dioxide fluid-flow modeling and injectivity calculations

    Science.gov (United States)

    Burke, Lauri

    2011-01-01

    At present, the literature lacks a geologic-based assessment methodology for numerically estimating injectivity, lateral migration, and subsequent long-term containment of supercritical carbon dioxide that has undergone geologic sequestration into subsurface formations. This study provides a method for and quantification of first-order approximations for the time scale of supercritical carbon dioxide lateral migration over a one-kilometer distance through a representative volume of rock. These calculations provide a quantified foundation for estimating injectivity and geologic storage of carbon dioxide.

  20. An Integrated Experimental-Modelling Procedure Applied to the Design of a Field Scale Goethite Nanoparticle Injection for the Remediation of Contaminated Sites

    Science.gov (United States)

    Bianco, C.; Tosco, T.; Sethi, R.

    2017-12-01

    Nanoremediation is a promising in-situ technology for the reclamation of contaminated aquifers. It consists in the subsurface injection of a reactive colloidal suspension for the in-situ treatment of pollutants. The overall success of this technology at the field scale is strictly related to the achievement of an effective and efficient emplacement of the nanoparticles (NP) inside the contaminated area. Mathematical models can be used to support the design of nanotechnology-based remediation by effectively assessing the expected NP mobility at the field scale. Several analytical and numerical tools have been developed in recent years to model the transport of NPs in simplified geometry and boundary conditions. The numerical tool MNMs was developed by the authors of this work to simulate colloidal transport in 1D Cartesian and radial coordinates. A new modelling tool, MNM3D (Micro and Nanoparticle transport Model in 3D geometries), was also proposed for the simulation of injection and transport of NP suspensions in generic complex scenarios. MNM3D accounts for the simultaneous dependency of NP transport on water ionic strength and velocity. The software was developed to predict the NP mobility at different stages of a nanoremediation application, from the design stage to the prediction of the long-term fate after injection. In this work an integrated experimental-modelling procedure is applied to support the design of a field scale injection of goethite NPs carried out in the framework of the H2020 European project Reground. Column tests are performed at different injection flowrates using natural sand collected at the contaminated site as porous medium. The tests are interpreted using MNMs to characterize the NP mobility and derive the constitutive equations describing the suspension behavior in the natural porous medium. MNM3D is then used to predict NP behavior during the field scale injection and to assess the long-term mobility of the injected slurry. Finally

  1. Collaborative testing for key-term definitions under representative conditions: Efficiency costs and no learning benefits.

    Science.gov (United States)

    Wissman, Kathryn T; Rawson, Katherine A

    2018-01-01

    Students are expected to learn key-term definitions across many different grade levels and academic disciplines. Thus, investigating ways to promote understanding of key-term definitions is of critical importance for applied purposes. A recent survey showed that learners report engaging in collaborative practice testing when learning key-term definitions, with outcomes also shedding light on the way in which learners report engaging in collaborative testing in real-world contexts (Wissman & Rawson, 2016, Memory, 24, 223-239). However, no research has directly explored the effectiveness of engaging in collaborative testing under representative conditions. Accordingly, the current research evaluates the costs (with respect to efficiency) and the benefits (with respect to learning) of collaborative testing for key-term definitions under representative conditions. In three experiments (ns = 94, 74, 95), learners individually studied key-term definitions and then completed retrieval practice, which occurred either individually or collaboratively (in dyads). Two days later, all learners completed a final individual test. Results from Experiments 1-2 showed a cost (with respect to efficiency) and no benefit (with respect to learning) of engaging in collaborative testing for key-term definitions. Experiment 3 evaluated a theoretical explanation for why collaborative benefits do not emerge under representative conditions. Collectively, outcomes indicate that collaborative testing versus individual testing is less effective and less efficient when learning key-term definitions under representative conditions.

  2. Treatment of the Infection after Fat Injection

    Directory of Open Access Journals (Sweden)

    Seok-Kwun Kim

    2015-01-01

    Full Text Available For recent years, use of autologous fat injection has increased significantly in facial contouring surgery. Along with such increase in use, complications like atypical mycoplasma infection have been also on the increasing trend. The authors report two cases of Mycobacterium chelonae infection that occurred after autologous fat injection. Patients were treated as infection that resistant to common antibiotics and results were negative to routine culture and Gram staining. Acid-fast bacillus stain, polymerase chain reaction (PCR test and mycobacterial cultures were conducted for diagnosis under suspicion of atypical mycoplasma infection. Then, combination antibiotics therapy, surgical treatment, and steroid injection were performed for treatment. Both patients were diagnosed with Mycobacterium chelonae in PCR test. They were positive to mycobacterial cultures. Combination antibiotics therapy was repeated to improvement of symptom. However, they could not be free from side effects such as deformation in facial contour, scar and pigmentation even after full recovery. When chronic wound infections after autologous fat injection, we must suspect atypical or mycobacterial infection and conduct examinations for a early diagnosis and proper antibiotic therapy that is effective to the nontuberculous mycobacteria.

  3. Facial volumetric correction with injectable poly-L-lactic acid.

    Science.gov (United States)

    Vleggaar, Danny

    2005-11-01

    Polymers of lactic acid'have been widely used for many years in different types of medical devices, such as resorbable sutures, intrabone implants, and soft tissue implants. Injectable poly-L-lactic acid (PLLA; Sculptra), a synthetic, biodegradable polymer, has gained widespread popularity in Europe for the treatment of facial changes associated with aging. To provide background information on injectable PLLA and to describe clinical experience with its use in Europe for facial volume enhancement. Technique varies with site of injection. Generally, the product is implanted subcutaneously or intradermally in a series of treatments. No allergy testing is required. Based on experience in more than 2,500 patients, injectable PLLA has been used successfully for the correction of nasolabial folds, mid- and lower facial volume loss, jawline laxity, and other signs of facial aging. Correction lasts for 18 to 24 months in most patients. Injectable PLLA treatment provides an excellent and prolonged correction of a variety of facial wrinkles, depressions, and laxity with a minimally invasive procedure that does not require allergy testing or a recovery period.

  4. An investigation of fluid mixing with safety injection in advanced reactors

    International Nuclear Information System (INIS)

    Cha, Jong Hee; Won, Soon Yean; Chung, Moon Ki; Jun, Hyung Gil

    1994-01-01

    The objective of this work is to investigate the fluid mixing phenomena in aspect of pressurized thermal shock(PTS) in an advanced PWR vessel downcomer during transient cooldown with safety injection. It provides comparison of fluid mixing characteristics between AP 600 DVI, designed by Westinghouse, and ABB CE System 80+ DVI, and the effects of deflector at the reactor downcomer. In order to investigate the fluid mixing phenomena in the downcomer of an advanced PWR, the flow visualization tests and the salt concentration tests were conducted in a 1/7-scale acrylic transparent model, which was designed and built based on AP 600 reactor geometry. The behaviour of the safety injection flow in downcomer associated with mixing phenomenon can be observed during visualization test, and time-dependent mixing rate between safety injection fluid and existing coolant can be determined with concentration test. Visualization tests were performed by the dye injection method. The results of concentration measurements were compared with the calculation using the REMIX code. During the tests, difference between AP 600 DVI flow and ABB CE System 80+ DVI flow and the effect of the deflector were observed

  5. Randomised controlled trial of local corticosteroid injections for de Quervain's tenosynovitis in general practice

    Directory of Open Access Journals (Sweden)

    Groenier Klaas H

    2009-10-01

    Full Text Available Abstract Background De Quervain's tenosynovitis is a stenosing tenosynovitis of the first dorsal compartment of the wrist and leads to wrist pain and to impaired function of the wrist and hand. It can be treated by splinting, local corticosteroid injection and operation. In this study effectiveness of local corticosteroid injections for de Quervain's tenosynovitis provided by general practitioners was assessed. Methods Participants with de Quervain's tenosynovitis were recruited by general practitioners. Short-term outcomes (one week after injections were assessed in a randomised, placebo-controlled trial. Long-term effectiveness was evaluated in an open prospective cohort-study of steroid responders during a follow-up period of 12 months. Participants were randomised to one or two local injections of 1 ml of triamcinolonacetonide (TCA or 1 ml of NaCl 0.9% (placebo. Non-responders to NaCl were treated with additional TCA injections. Main outcomes were immediate treatment response, severity of pain, improvement as perceived by participant and functional disability using sub items hand and finger function of the Dutch Arthritis Impact Measurement Scale (Dutch AIMS-2-HFF. Results 11 general practitioners included 21 wrists in 21 patients. The TCA-group had better results for short-term outcomes treatment response (78% vs. 25%; p = 0.015, perceived improvement (78% vs. 33%; p = 0.047 and severity of pain (4.27 vs. 1.33; p = 0.031 but not for the Dutch-AIMS-HFF (2.71 vs. 1.92; p = 0.112. Absolute risk reduction for the main outcome short-term treatment response was 0.55 (95% CI: 0.34, 0.76 with a number needed to treat of 2 (95% CI: 1, 3. In the cohort of steroid responders (n = 12 the beneficial effects of steroid injections were sustained during the follow-up of 12 months regarding severity of pain (p = 0.67 and scores of Dutch AIMS-2-HFF (p = 0.36, but not for patient perceived improvement (p = 0.02. No adverse events were observed during the 12

  6. TEPSS related PANDA tests (ESBWR)

    International Nuclear Information System (INIS)

    Huggenberger, M.; Aubert, C.; Bandurski, T.; Dreier, J.; Fischer, O.; Strassberger, H.J.; Yadigaroglu, G.

    2000-01-01

    A number of test series to investigate passive safety systems for the next generation of Light Water Reactors have been performed in the PANDA facility at the Paul Scherrer Institute (PSI). The large scale thermalhydraulic test facility allows to investigate Passive Containment Cooling Systems (PCCS) and the long-term containment behaviour after a Loss of Coolant Accident (LOCA). After successful completion of the ALPHA phase-I test series, where the PCCS performance of the Simplified Boiling Water Reactor (SBWR) was examined, phase-II was initiated in 1996 with new projects, all with international participation (EC Fourth Framework Programme on Nuclear Fission Safety). One of these projects is entitled 'Technology Enhancement for Passive Safety Systems' (TEPSS). TEPSS is focused on the European Simplified Boiling Water Reactor (ESBWR). Several new containment features and PCCS long-term response under different LOCA scenarios were investigated in PANDA. The PCCS start-up was demonstrated under challenging conditions. The effect of nitrogen hidden somewhere in the drywell and released later in the transient was simulated by injecting air for a certain period into the drywell. The effect of light gases on the PCCS performance was investigated by helium injection to the drywell. Finally, the influence of low PCC pool levels on PCCS and containment performance was examined. The main findings were that the PCCS works as intended and shows generally a favourable and robust long-term post LOCA behaviour. The system starts working even under extreme conditions and trapped air released from the drywell later in the transient does only temporarily reduce the PCCS performance. The new PANDA test series provided an extensive data base which will contribute to further improve containment design of passive plants and allow for system code assessment in a wide parameter range. (author)

  7. Review of short-term screening tests for mutagens, toxigens, and carcinogens

    Energy Technology Data Exchange (ETDEWEB)

    Carney, H.J.; Hass, B.S.

    1979-07-01

    In order to test the thousands of man-made chemicals in the environment for carcinogenic and genetic hazards, a multitude of short-term screening tests has been developed to complement long-term mammalian bioassays and epidemiological studies. These tests cover a broad spectrum of organisms, and include the use of naked and viral nucleic acids, bacteria, fungi, higher plants, insects in vitro mammalian cell cultures (cell transformation, cell-mediated mutagenesis, DNA repair, and chromosome aberration tests) and live mammals. Assay end points include effects on nucleic acids, DNA repair synthesis, point or gene mutation, structural and numerical chromosome aberrations, cytological alterations, and in vitro cell transformation. The present review describes and compares these assays. In addition, it discusses their historical development, the problems and limitations associated with their use, and their implementation in comprehensive testing programs. It is intended to provide overview and specific information to the laboratory that is in the process of establishing genetic toxicological systems. (The literature is reviewed to January 1978.)

  8. Experimental Investigation of Diffuser Hub Injection to Improve Centrifugal Compressor Stability

    Science.gov (United States)

    Skoch, Gary J.

    2004-01-01

    Results from a series of experiments to investigate whether centrifugal compressor stability could be improved by injecting air through the diffuser hub surface are reported. The research was conducted in a 4:1 pressure ratio centrifugal compressor configured with a vane-island diffuser. Injector nozzles were located just upstream of the leading edge of the diffuser vanes. Nozzle orientations were set to produce injected streams angled at 8, 0 and +8 degrees relative to the vane mean camber line. Several injection flow rates were tested using both an external air supply and recirculation from the diffuser exit. Compressor flow range did not improve at any injection flow rate that was tested. Compressor flow range did improve slightly at zero injection due to the flow resistance created by injector openings on the hub surface. Leading edge loading and semi-vaneless space diffusion showed trends similar to those reported earlier from shroud surface experiments that did improve compressor flow range. Opposite trends are seen for hub injection cases where compressor flow range decreased. The hub injection data further explain the range improvement provided by shroud-side injection and suggest that different hub-side techniques may produce range improvement in centrifugal compressors.

  9. HIV and injecting drug use in Indonesia: epidemiology and national response.

    Science.gov (United States)

    Afriandi, Irvan; Aditama, Tjandra Yoga; Mustikawati, Dyah; Oktavia, Martiani; Alisjahbana, Bachti; Riono, Pandu

    2009-07-01

    Indonesia is facing one of the most rapidly growing HIV-epidemics in Asia. Risk behaviour associated with injecting drug use, such as sharing contaminated needles, is the main risk factor for HIV infection. Among the general population the prevalence of HIV-infection is still low (0.2%), but up to 50% or more of the estimated 145.000 - 170.000 injecting drug users are already HIV-positive. Overrepresentation of injecting drug users and continued risk behavior inside Indonesian prisons contribute to spread of HIV. Through sexual contacts, HIV is transmitted from current or previous injecting drug users to their non-injecting sexual partners; 10-20% of this group may already be infected. The national response targeted to limit spread of HIV through injecting drug use has included needle and syringe program (NSP), methadone maintenance treatment (MMT), voluntary counseling and testing (VCT), and outreach program as priority programs. However coverage and utilization of the harm reduction services is still limited, but effective integration with HIV testing and treatment is expanding. By 2008, there were 110 service points for NSP and 24 operational MMT clinics. Nevertheless, utilization of these services has been less satisfactory and their effectiveness has been questioned. Besides effective prevention, HIV- testing and earlier treatment of HIV-seropositve individuals, including those with a history of injecting drug use, will help control the growing HIV-epidemic in Indonesia.

  10. Cold leg injection reflood test results in the SCTF Core-I under constant system pressure

    International Nuclear Information System (INIS)

    Adachi, Hiromichi; Iwamura, Takamichi; Sobajima, Makoto; Osakabe, Masahiro; Ohnuki, Akira; Abe, Yutaka; Murao, Yoshio.

    1990-08-01

    The Slab Core Test Facility (SCTF) was constructed to investigate two-dimensional thermal-hydrodynamics in the core and the interaction in fluid behavior between the core and the upper plenum during the last part of blowdown, refill and reflood phases of a postulated loss-of-coolant accident (LOCA) of a pressurized water reactor (PWR). The present report describes the analytical results on the system behavior observed in the SCTF Core-I cold leg injection tests, S1-14 (Run 520), S1-15 (521), S1-16 (522), S1-17 (523), S1-20 (530), S1-21 (531), S1-23 (536) and S1-24 (537), performed under constant system pressure condition during transient. Major discussion items are: (1) steam binding, (2) U-tube oscillations, (3) bypass of ECC water (4) core cooling behavior, (5) effect of vent valve and (6) other parameter effects. These results give us very useful information and suggestion on reflood behavior. (author)

  11. Dual fuel injection piggyback controller system

    Science.gov (United States)

    Muji, Siti Zarina Mohd.; Hassanal, Muhammad Amirul Hafeez; Lee, Chua King; Fawzi, Mas; Zulkifli, Fathul Hakim

    2017-09-01

    Dual-fuel injection is an effort to reduce the dependency on diesel and gasoline fuel. Generally, there are two approaches to implement the dual-fuel injection in car system. The first approach is changing the whole injector of the car engine, the consequence is excessive high cost. Alternatively, it also can be achieved by manipulating the system's control signal especially the Electronic Control Unit (ECU) signal. Hence, the study focuses to develop a dual injection timing controller system that likely adopted to control injection time and quantity of compressed natural gas (CNG) and diesel fuel. In this system, Raspberry Pi 3 reacts as main controller unit to receive ECU signal, analyze it and then manipulate its duty cycle to be fed into the Electronic Driver Unit (EDU). The manipulation has changed the duty cycle to two pulses instead of single pulse. A particular pulse mainly used to control injection of diesel fuel and another pulse controls injection of Compressed Natural Gas (CNG). The test indicated promising results that the system can be implemented in the car as piggyback system. This article, which was originally published online on 14 September 2017, contained an error in the acknowledgment section. The corrected acknowledgment appears in the Corrigendum attached to the pdf.

  12. Performance of ARCHITECT HCV core antigen test with specimens from US plasma donors and injecting drug users.

    Science.gov (United States)

    Mixson-Hayden, Tonya; Dawson, George J; Teshale, Eyasu; Le, Thao; Cheng, Kevin; Drobeniuc, Jan; Ward, John; Kamili, Saleem

    2015-05-01

    Hepatitis C virus (HCV) core antigen is a serological marker of current HCV infection. The aim of this study was mainly to evaluate the performance characteristics of the ARCHITECT HCV core antigen assay with specimens from US plasma donors and injecting drug users. A total of 551 serum and plasma samples with known anti-HCV and HCV RNA status were tested for HCV core antigen using the Abbott ARCHITECT HCV core antigen test. HCV core antigen was detectable in 100% of US plasma donor samples collected during the pre-seroconversion phase of infection (anti-HCV negative/HCV RNA positive). Overall sensitivity of the HCV core antigen assay was 88.9-94.3% in samples collected after seroconversion. The correlation between HCV core antigen and HCV RNA titers was 0.959. HCV core antigen testing may be reliably used to identify current HCV infection. Published by Elsevier B.V.

  13. Assessment of leak detection capability of Candu 6 annulus gas system using moisture injection tests

    International Nuclear Information System (INIS)

    Nho, Ki Man; Kim, Wang Bae

    1998-01-01

    The Candu 6 reactor assembly consists of an array of 380 pressure tubes, which are installed horizontally in a large cylindrical vessel, the Calandria, containing the low pressure heavy water moderator. The pressure tube is located inside calandria tube and the annulus between these tubes, which forms a closed loop with CO 2 gas recirculating, is called the Annulus Gas System (AGS). It is designed to give an alarm to the operator even for a small pressure tube leak by a very sensitive dew point meter so that he can take a preventive action for the pressure tbe rupture incident. To judge whether the operator action time is enough or not in the design of Wolsung 2, 3, and 4, the Leak Before Break (LBB) assessment is required for the analysis of the pressure tube failure accident. In order to provide the required data for the LBB assessment of Wolsung Units 2, 3, 4, a series of leak detection capability tests was performed by injecting controlled rates of heavy water vapour. The data of increased dew point and rates of rise were measured to determine the alarm set point for dew point rate of rise of Wolsung Unit 2. It was found that the response of the dew point depends on the moisture injection rate, CO 2 gas flow rate and the leak location. The test showed that Candu 6 AGS can detect the very small leaks less than few g/hr and dew point rate of rise alarm can be the most reliable alarm signal to warn the operator. Considering the present results, the first response time of dew point to the AGS CO 2 flow rate is approximated. (author)

  14. Double Tunneling Injection Quantum Dot Lasers for High Speed Operation

    Science.gov (United States)

    2017-10-23

    Double Tunneling-Injection Quantum Dot Lasers for High -Speed Operation The views, opinions and/or findings contained in this report are those of...SECURITY CLASSIFICATION OF: 1. REPORT DATE (DD-MM-YYYY) 4. TITLE AND SUBTITLE 13. SUPPLEMENTARY NOTES 12. DISTRIBUTION AVAILIBILITY STATEMENT 6...State University Title: Double Tunneling-Injection Quantum Dot Lasers for High -Speed Operation Report Term: 0-Other Email: asryan@vt.edu Distribution

  15. Numerical investigation of the effect of injection strategy on mixture formation and combustion process in a port injection natural gas rotary engine

    International Nuclear Information System (INIS)

    Fan, Baowei; Pan, Jianfeng; Yang, Wenming; Liu, Yangxian; Bani, Stephen; Chen, Wei

    2017-01-01

    Highlights: • For injection timing, the fuel movement is controlled by the intensity of the vortex I. • For injection duration, the fuel movement is controlled by the value of jet flux. • The ideal fuel distribution at ignition timing for high combustion rate is studied. • The optimal injection strategy had an increase in the peak pressure and NO emissions. - Abstract: This work aimed to numerically study the influence of injection strategy on mixture formation and combustion process in a port injection natural gas rotary engine. On the base of a 3D dynamic simulation model which was established in our previous work, some critical information was obtained, which was difficult to obtain through experiment, in terms of the flow field, the fuel distribution, the temperature field and the concentration fields of some intermediates. Simulation results showed that for mixture formation, the movements of fuel in injection stage were mainly controlled by the intensity of the vortex I for injection timing, and the value of jet flux for injection duration respectively. With retarded injection timing, the decreasing intensity of the vortex I resulted in less fuel moving toward the back of the combustion chamber. With the extension in injection duration, the decreasing value of jet flux resulted in more fuel staying at the back of the combustion chamber. For combustion process, the overall combustion rate for injection strategy which had an injection timing of 390 °CA (BTDC) and injection duration of 51.5 °CA (case ID4) was the fastest. This was mainly due to the fact that the accumulation area of fuel was at the middle and front of the combustion chamber. Meanwhile, fuel concentration near the leading and trailing spark plugs was conducive for the flame kernel formation. Compared with the injection strategy which had an injection timing of 450 °CA (BTDC) and an injection duration of 55 °CA (case IT1), the improved combustion rate of case ID4 had a 23% increase in

  16. Optimising corticosteroid injection for lateral epicondylalgia with the addition of physiotherapy: A protocol for a randomised control trial with placebo comparison

    Directory of Open Access Journals (Sweden)

    Brooks Peter

    2009-06-01

    Full Text Available Abstract Background Corticosteroid injection and physiotherapy are two commonly prescribed interventions for management of lateral epicondylalgia. Corticosteroid injections are the most clinically efficacious in the short term but are associated with high recurrence rates and delayed recovery, while physiotherapy is similar to injections at 6 weeks but with significantly lower recurrence rates. Whilst practitioners frequently recommend combining physiotherapy and injection to overcome harmful effects and improve outcomes, study of the benefits of this combination of treatments is lacking. Clinicians are also faced with the paradox that the powerful anti-inflammatory corticosteroid injections work well, albeit in the short term, for a non-inflammatory condition like lateral epicondylalgia. Surprisingly, these injections have not been rigorously tested against placebo injections. This study primarily addresses both of these issues. Methods A randomised placebo-controlled clinical trial with a 2 × 2 factorial design will evaluate the clinical efficacy, cost-effectiveness and recurrence rates of adding physiotherapy to an injection. In addition, the clinical efficacy and adverse effects of corticosteroid injection beyond that of a placebo saline injection will be studied. 132 participants with a diagnosis of lateral epicondylalgia will be randomly assigned by concealed allocation to one of four treatment groups – corticosteroid injection, saline injection, corticosteroid injection with physiotherapy or saline injection with physiotherapy. Physiotherapy will comprise 8 sessions of elbow manipulation and exercise over an 8 week period. Blinded follow-up assessments will be conducted at baseline, 4, 8, 12, 26 and 52 weeks after randomisation. The primary outcome will be a participant rating of global improvement, from which measures of success and recurrence will be derived. Analyses will be conducted on an intention-to-treat basis using linear

  17. Numerical simulation for cyclic steam injection at Santa Clara field

    International Nuclear Information System (INIS)

    Rodriguez, Edwin; Barrios, Wilson; Sandoval, Roy; Santos, Nicolas; Cortes, Ingrid

    2008-01-01

    This article presents the methodology used and the results obtained in the construction, match and prediction of the first thermal composition simulation model done in Colombia by employing advanced thermal process commercial software, globally recognized because of its effectiveness in modeling these types of processes (CMG-STARS, 2005). The Santa Clara and Palermo fields were modeled and an excellent history match was achieved. All in all 28 wells and 17 years of production were matched. Two production scenes were proposed. The first involved primary production from existing wells, in other words: primary production; and a second scene where all the wells in the field are converted into injectors and producers, to simulate cyclic steam injection. This injection process included a series of sensitivity studies for several of the parameters involved in this technology, such as: pressure and temperature injection, time and rate of injection, heat injected, soaking period, steam quality, and injection cycles. This sensitivity study was focused on optimizing the processes to obtain the maximum end recovery possible. The information entered into the simulator was validated by laboratory tests developed at the Instituto Colombiano del Petroleo (ICP). Among the tests performed the following were assessed: rock compressibility, relative permeability curve behavior at different temperatures, formation sensitivity to injection fluids, DRX analysis and residual saturation of crude oil for steam injection. The aforementioned results are documented in this paper

  18. "The first shot": the context of first injection of illicit drugs, ongoing injecting practices, and hepatitis C infection in Rio de Janeiro, Brazil

    Directory of Open Access Journals (Sweden)

    Maria de Lourdes Aguiar Oliveira

    Full Text Available The context of first drug injection and its association with ongoing injecting practices and HCV (hepatitis C virus infection were investigated. Injection drug users (IDUs (N = 606 were recruited in "drug scenes" (public places, bars in Rio de Janeiro, Brazil, interviewed, and tested for HCV. Sharing of needles/syringes was more prevalent at the first injection (51.3% than at the baseline interview (36.8%. Those who shared syringes/needles at first injection were more likely to be currently engaged in direct/indirect sharing practices. Among young injectors (< 30 years, those reporting sharing of needles/ syringes at the first injection were about four times more likely to have been infected by HCV. Hepatitis C virus prevalence among active IDUs (n = 272 was 11%. Prison history and longer duration of drug injection were identified as independent predictors of HCV infection. To effectively curb HCV transmission among IDUs and minimize harms associated with risk behaviors, preventive strategies should target individuals initiating drug injection beginning with their very first injection and discourage the transition from non-injecting use to the self-injection of illicit drugs.

  19. An update on blast furnace granular coal injection

    Energy Technology Data Exchange (ETDEWEB)

    Hill, D.G. [Bethlehem Steel Corp., Burns Harbor, IN (United States); Strayer, T.J.; Bouman, R.W. [Bethlehem Steel Corp., PA (United States)

    1997-12-31

    A blast furnace coal injection system has been constructed and is being used on the furnace at the Burns Harbor Division of Bethlehem Steel. The injection system was designed to deliver both granular (coarse) and pulverized (fine) coal. Construction was completed on schedule in early 1995. Coal injection rates on the two Burns Harbor furnaces were increased throughout 1995 and was over 200 lbs/ton on C furnace in September. The injection rate on C furnace reached 270 lbs/ton by mid-1996. A comparison of high volatile and low volatile coals as injectants shows that low volatile coal replaces more coke and results in a better blast furnace operation. The replacement ratio with low volatile coal is 0.96 lbs coke per pound of coal. A major conclusion of the work to date is that granular coal injection performs very well in large blast furnaces. Future testing will include a processed sub-bituminous coal, a high ash coal and a direct comparison of granular versus pulverized coal injection.

  20. Pre-test analysis of ATLAS SBO with RCP seal leakage scenario using MARS code

    Energy Technology Data Exchange (ETDEWEB)

    Pham, Quang Huy; Lee, Sang Young; Oh, Seung Jong [KEPCO International Nuclear Graduate School, Ulsan (Korea, Republic of)

    2015-10-15

    This study presents a pre-test calculation for the Advanced Thermal-hydraulic Test Loop for Accident Simulation (ATLAS) SBO experiment with RCP seal leakage scenario. Initially, turbine-driven auxfeed water pumps are used. Then, outside cooling water injection method is used for long term cooling. The analysis results would be useful for conducting the experiment to verify the APR 1400 extended SBO optimum mitigation strategy using outside cooling water injection in future. The pre-test calculation for ATLAS extended SBO with RCP seal leakage and outside cooling water injection scenario is performed. After Fukushima nuclear accident, the capability of coping with the extended station blackout (SBO) becomes important. Many NPPs are applying FLEX approach as main coping strategies for extended SBO scenarios. In FLEX strategies, outside cooling water injection to reactor cooling system (RCS) and steam generators (SGs) is considered as an effective method to remove residual heat and maintain the inventory of the systems during the accident. It is worthwhile to examine the soundness of outside cooling water injection method for extended SBO mitigation by both calculation and experimental demonstration. From the calculation results, outside cooling water injection into RCS and SGs is verified as an effective method during extended SBO when RCS and SGs depressurization is sufficiently performed.

  1. Injectable hydrogels derived from phosphorylated alginic acid calcium complexes

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Han-Sem; Song, Minsoo, E-mail: minsoosong00@gmail.com; Lee, Eun-Jung; Shin, Ueon Sang, E-mail: usshin12@dankook.ac.kr

    2015-06-01

    Phosphorylation of sodium alginate salt (NaAlg) was carried out using H{sub 3}PO{sub 4}/P{sub 2}O{sub 5}/Et{sub 3}PO{sub 4} followed by acid–base reaction with Ca(OAc){sub 2} to give phosphorylated alginic acid calcium complexes (CaPAlg), as a water dispersible alginic acid derivative. The modified alginate derivatives including phosphorylated alginic acid (PAlg) and CaPAlg were characterized by nuclear magnetic resonance spectroscopy for {sup 1}H, and {sup 31}P nuclei, high resolution inductively coupled plasma optical emission spectroscopy, Fourier transform infrared spectroscopy, and thermogravimetric analysis. CaPAlg hydrogels were prepared simply by mixing CaPAlg solution (2 w/v%) with NaAlg solution (2 w/v%) in various ratios (2:8, 4:6, 6:4, 8:2) of volume. No additional calcium salts such as CaSO{sub 4} or CaCl{sub 2} were added externally. The gelation was completed within about 3–40 min indicating a high potential of hydrogel delivery by injection in vivo. Their mechanical properties were tested to be ≤ 6.7 kPa for compressive strength at break and about 8.4 kPa/mm for elastic modulus. SEM analysis of the CaPAlg hydrogels showed highly porous morphology with interconnected pores of width in the range of 100–800 μm. Cell culture results showed that the injectable hydrogels exhibited comparable properties to the pure alginate hydrogel in terms of cytotoxicity and 3D encapsulation of cells for a short time period. The developed injectable hydrogels showed suitable physicochemical and mechanical properties for injection in vivo, and could therefore be beneficial for the field of soft tissue engineering. - Highlights: • Preparation of water-soluble alginic acid complexes with calcium phosphate • Self-assembly of the phosphorylated alginic acid calcium complexes with sodium alginate • Preparation of injectable hydrogels with diverse gelation times within about 3–40 min.

  2. Low pressure powder injection moulding of stainless steel powders

    Energy Technology Data Exchange (ETDEWEB)

    Zampieron, J.V.; Soares, J.P.; Mathias, F.; Rossi, J.L. [Powder Processing Center CCP, Inst. de Pesquisas Energeticas e Nucleares, Sao Paulo, SP (Brazil); Filho, F.A. [IPEN, Inst. de Pesquisas Energeticas e Nucleares, Cidade Univ., Sao Paulo, SP (Brazil)

    2001-07-01

    Low-pressure powder injection moulding was used to obtain AISI 316L stainless steel parts. A rheological study was undertaken using gas-atomised powders and binders. The binders used were based on carnauba wax, paraffin, low density polyethylene and microcrystalline wax. The metal powders were characterised in terms of morphology, particle size distribution and specific surface area. These results were correlated to the rheological behaviour. The mixture was injected in the shape of square bar specimens to evaluate the performance of the injection process in the green state, and after sintering. The parameters such as injection pressure, viscosity and temperature were analysed for process optimisation. The binders were thermally removed in low vacuum with the assistance of alumina powders. Debinding and sintering were performed in a single step. This procedure shortened considerably the debinding and sintering time. (orig.)

  3. Non-injection Drug Use and Injection Initiation Assistance among People Who Inject Drugs in Tijuana, Mexico.

    Science.gov (United States)

    Ben Hamida, Amen; Rafful, Claudia; Jain, Sonia; Sun, Shelly; Gonzalez-Zuniga, Patricia; Rangel, Gudelia; Strathdee, Steffanie A; Werb, Dan

    2018-02-01

    Although most people who inject drugs (PWID) report receiving assistance during injection initiation events, little research has focused on risk factors among PWID for providing injection initiation assistance. We therefore sought to determine the influence of non-injection drug use among PWID on their risk to initiate others. We used generalized estimating equation (GEE) models on longitudinal data among a prospective cohort of PWID in Tijuana, Mexico (Proyecto El Cuete IV), while controlling for potential confounders. At baseline, 534 participants provided data on injection initiation assistance. Overall, 14% reported ever initiating others, with 4% reporting this behavior recently (i.e., in the past 6 months). In a multivariable GEE model, recent non-injection drug use was independently associated with providing injection initiation assistance (adjusted odds ratio [AOR] = 2.42, 95% confidence interval [CI] = 1.39-4.20). Further, in subanalyses examining specific drug types, recent non-injection use of cocaine (AOR = 9.31, 95% CI = 3.98-21.78), heroin (AOR = 4.00, 95% CI = 1.88-8.54), and methamphetamine (AOR = 2.03, 95% CI = 1.16-3.55) were all significantly associated with reporting providing injection initiation assistance. Our findings may have important implications for the development of interventional approaches to reduce injection initiation and related harms. Further research is needed to validate findings and inform future approaches to preventing entry into drug injecting.

  4. Injection, injectivity and injectability in geothermal operations: problems and possible solutions. Phase I. Definition of the problems

    Energy Technology Data Exchange (ETDEWEB)

    Vetter, O.J.; Crichlow, H.B.

    1979-02-14

    The following topics are covered: thermodynamic instability of brine, injectivity loss during regular production and injection operations, injectivity loss caused by measures other than regular operations, heat mining and associated reservoir problems in reinjection, pressure maintenance through imported make-up water, suggested solutions to injection problems, and suggested solutions to injection problems: remedial and stimulation measures. (MHR)

  5. Long term safety, efficacy, and patient acceptability of hyaluronic acid injection in patients with painful osteoarthritis of the knee

    Science.gov (United States)

    McArthur, Benjamin A; Dy, Christopher J; Fabricant, Peter D; Valle, Alejandro Gonzalez Della

    2012-01-01

    The increasing prevalence of painful knee osteoarthritis has created an additional demand for pharmacologic management to prevent or delay surgical management. Viscosupplementation, via intraarticular injection of hyaluronic acid (HA), aims to restore the favorable milieu present in the nonarthritic joint. The safety profile of intraarticular HA injections for painful knee osteoarthritis is well established, with the most common adverse effect being a self-limited reaction at the injection site. Although acceptance of the early literature has been limited by publication bias and poor study quality, more recent and rigorous meta-analysis suggests that intraarticular HA injection is superior to placebo injection for pain relief and matches, if not surpasses, the effect size of other nonoperative treatments, such as nonsteroidal anti-inflammatory medication. Intraarticular HA injection is effective in providing temporary pain relief in patients with painful knee osteoarthritis. Future investigations should focus on optimizing the composition and administration of HA agents to provide prolonged relief of painful osteoarthritis in the knee and other joints. PMID:23271899

  6. Test results of pongamia pinnata methyl esters with direct injection diesel engine

    International Nuclear Information System (INIS)

    Bannikov, MG.; Chattha, J.A.; Khan, A.F.

    2011-01-01

    Pongamia Pinnata oil is considered as a potential source of biodiesel production in Pakistan. When selecting source for commercial production of biodiesel several criteria are used. One of them is that biodiesel or biodiesel/diesel fuel blends must provide satisfactory performance and emissions of the diesel engine without or with a little engine modification. In this research performance and emissions characteristics of a direct injection diesel engine running on Pongamia Pinnata methyl esters were discussed. Discussion was supported by an analysis of combustion characteristics derived from in-cylinder pressure data. Engine running on a neat biodiesel showed higher brake specific fuel consumption and lower brake fuel conversion efficiency at all loads, whereas emissions were improved except of carbon monoxide emission at high loads. Decrease in brake efficiency and reduction of nitrogen oxides emissions were attributed solely to the change in the rate of heat release. Deposits on fuel infector nozzle were observed when engine was running on the neat biodiesel. Based on test results conclusion was made that Pongamia biodiesel/diesel fuel blends can effectively be used as a diesel oil substitute. (author)

  7. TARA beamline and injection system

    International Nuclear Information System (INIS)

    Post, R.S.; Brindza, P.; Coleman, J.W.; Torti, R.P.; Blackfield, D.T.; Goodrich, P.

    1983-01-01

    The TARA beamline for neutral beam injection will permit one to three sources to fire into each plug (60 degree or optional 90 degree injection with respect to the TARA axis) or into each anchor (90 degree injection only). The sources, pre-aimed on their mounting plate at the NB test stand, may be fired into neutralizer ducts or optionally through a magnesium curtain, and the unneutralized fraction is dumped by the TARA fringing field onto a receiver plate. The beamline is housed in a cylindrical tank with the beam axis along the tank diameter at the midplane. The tank will be sorption pumped using LN + T/sub I/ or N/sub B/ and/or e-beam gettering. The beam burial tank contains sed arrays and a thin foil dump which reaches sufficiently high temperatures during the shot to boil out gas between shots

  8. Experimental optimization of a direct injection homogeneous charge compression ignition gasoline engine using split injections with fully automated microgenetic algorithms

    Energy Technology Data Exchange (ETDEWEB)

    Canakci, M. [Kocaeli Univ., Izmit (Turkey); Reitz, R.D. [Wisconsin Univ., Dept. of Mechanical Engineering, Madison, WI (United States)

    2003-03-01

    Homogeneous charge compression ignition (HCCI) is receiving attention as a new low-emission engine concept. Little is known about the optimal operating conditions for this engine operation mode. Combustion under homogeneous, low equivalence ratio conditions results in modest temperature combustion products, containing very low concentrations of NO{sub x} and particulate matter (PM) as well as providing high thermal efficiency. However, this combustion mode can produce higher HC and CO emissions than those of conventional engines. An electronically controlled Caterpillar single-cylinder oil test engine (SCOTE), originally designed for heavy-duty diesel applications, was converted to an HCCI direct injection (DI) gasoline engine. The engine features an electronically controlled low-pressure direct injection gasoline (DI-G) injector with a 60 deg spray angle that is capable of multiple injections. The use of double injection was explored for emission control and the engine was optimized using fully automated experiments and a microgenetic algorithm optimization code. The variables changed during the optimization include the intake air temperature, start of injection timing and the split injection parameters (per cent mass of fuel in each injection, dwell between the pulses). The engine performance and emissions were determined at 700 r/min with a constant fuel flowrate at 10 MPa fuel injection pressure. The results show that significant emissions reductions are possible with the use of optimal injection strategies. (Author)

  9. Study on the correlation between long-term exposure tests and accelerated corrosion tests by the combined damage of salts

    International Nuclear Information System (INIS)

    Park, Sang Soon; Lee, Min Woo

    2014-01-01

    Interest in the durability assessment and structural performance has increased according to an increase of concrete structures in salt damage environment recent years. Reliable way ensuring the most accelerated corrosion test is a method of performing the rebar corrosion monitoring as exposed directly to the marine test site exposure. However, long-term exposure test has a disadvantage because of a long period of time. Therefore, many studies on reinforced concrete in salt damage environments have been developed as alternatives to replace this. However, accelerated corrosion test is appropriate to evaluate the critical chlorine concentration in the short term, but only accelerated test method, is not easy to get correct answer. Accuracy of correlation acceleration test depends on the period of the degree of exposure environments. Therefore, in this study, depending on the concrete mix material, by the test was performed on the basis of the composite degradation of the salt damage, and investigate the difference of corrosion initiation time of the rebar, and indoor corrosion time of the structure, of the marine environment of the actual environments were investigated. The correlation coefficient was derived in the experiment. Long-term exposure test was actually conducted in consideration of the exposure conditions submerged zone, splash zone and tidal zone. The accelerated corrosion tests were carried out by immersion conditions, and by the combined deterioration due to the carbonation and accelerated corrosion due to wet and dry condition

  10. Water injection profiling

    International Nuclear Information System (INIS)

    Arnold, D.M.

    1982-01-01

    A method of neutron-gamma logging is described, in which water, injected in a cased well borehole with peforations, is irradiated with neutrons of 10 MeV or greater, and subsequent gamma radiation is detected by a pair of detectors along the borehole. Counting rates of detectors are analyzed in terms of two gamma ray energy windows. Linear flow velocity of fluid moving downward within the casing is used in conjunction with count rate data to determine volume flow rates of water moving in other directions. Apparatus includes a sonde with a neutron source and appropriate gamma sensors

  11. Numerical research on the scroll compressor with refrigeration injection

    International Nuclear Information System (INIS)

    Wang Baolong; Shi Wenxing; Li Xianting; Yan Qisen

    2008-01-01

    A general model for a scroll compressor with refrigerant injection is established in this paper. The model can be used to predict the macro performance and inner compression process of the injected scroll compressor. A series of experiments are conducted to validate the accuracy of the model. The results show that the model can precisely predict not only the general performance of the compressor but also the inner compression with or without refrigerant injection. Based on the thermodynamic model and the test bench, the injection process of the scroll compressor has been investigated and the thermodynamic essence is revealed. It is found that the refrigerant injection process can be considered as a continual parameter-varying 'adiabatic throttling + isobaric mixture' time-varying process

  12. Frequency of booster injections of allergoids.

    Science.gov (United States)

    Norman, P S; Creticos, P S; Marsh, D G

    1990-01-01

    In 1982, 43 ragweed-sensitive patients receiving maintenance injections of full doses of ragweed allergoid were selected for a study of the immunologic and clinical efficacy of booster injections only four times a year. These patients had participated for 2 to 7 years as part of a trial of mixes of up to four allergoids to common pollens in the mid-Atlantic area tailored to each patient's skin test sensitivity. They were divided into a group (21 patients) to receive injections every 3 months and a group (22 patients) to receive injections about every 6 weeks (eight injections per year). Patients were rerandomized after 1 year so that half of each original group switched to the alternate treatment, and this program was continued until after the ragweed season of 1985. Thirty-four patients were still under study the last year. Doses, per injection, were 100 allergoid units (1 allergoid unit equals 100 PNU) of each allergen in the mixture. Symptom scores during the 8 weeks of each of the four ragweed seasons were not significantly higher in the 3-month treated group. IgG antibody levels to Amb a I (antigen E) were followed until early 1984 and were not significantly different in the two groups, even though the 6-week treated patients received a two times higher cumulative dose per year. Rates of local and systemic reactions (percent of injections eliciting reactions) were not different in the groups, which means that the 3-month treated group had about half as many reactions by virtue of taking half as many injections.(ABSTRACT TRUNCATED AT 250 WORDS)

  13. Large-Signal Injection-Level Spectroscopy of Impurities in Silicon

    International Nuclear Information System (INIS)

    Ahrenkiel, R.K.; Johnston, S.W.

    1998-01-01

    Deep level defects in silicon are identified by measuring the recombination lifetime as a function of the injection level. The basic models for recombination at deep and shallow centers is developed. The defect used for the theoretical model is the well-known interstitial Fe ion in silicon. Data are presented on silicon samples ranging in defect content from intentionally Fe-doped samples to an ultra-pure float-zone grown sample. These data are analyzed in terms of the injection-level spectroscopy model

  14. Testosterone Injection

    Science.gov (United States)

    ... typical male characteristics. Testosterone injection works by supplying synthetic testosterone to replace the testosterone that is normally ... as a pellet to be injected under the skin.Testosterone injection may control your symptoms but will ...

  15. Influence of injection timing on the exhaust emissions of a dual-fuel CI engine

    Energy Technology Data Exchange (ETDEWEB)

    Sayin, Cenk [Department of Mechanical Education, Marmara University, 34722 Istanbul (Turkey); Uslu, Kadir [Department of Automotive Education, Fatih Vocational High School, 54100 Sakarya (Turkey); Canakci, Mustafa [Department of Mechanical Education, Kocaeli University, 41380 Kocaeli (Turkey); Alternative Fuels R and D Center, Kocaeli University, 41040 Kocaeli (Turkey)

    2008-06-15

    Environmental concerns and limited amount of petroleum fuels have caused interests in the development of alternative fuels for internal combustion (IC) engines. As an alternative, biodegradable, and renewable fuel, ethanol is receiving increasing attention. Therefore, in this study, influence of injection timing on the exhaust emission of a single cylinder, four stroke, direct injection, naturally aspirated diesel engine has been experimentally investigated using ethanol blended diesel fuel from 0% to 15% with an increment of 5%. The engine has an original injection timing 27 CA BTDC. The tests were performed at five different injection timings (21 , 24 , 27 , 30 , and 33 CA BTDC) by changing the thickness of advance shim. The experimental test results showed that NO{sub x} and CO{sub 2} emissions increased as CO and HC emissions decreased with increasing amount of ethanol in the fuel mixture. When compared to the results of original injection timing, at the retarded injection timings (21 and 24 CA BTDC), NO{sub x} and CO{sub 2} emissions increased, and unburned HC and CO emissions decreased for all test conditions. On the other hand, with the advanced injection timings (30 and 33 CA BTDC), HC and CO emissions diminished, and NO{sub x} and CO{sub 2} emissions boosted for all test conditions. (author)

  16. Fat Injection: A Systematic Review of Injection Volumes by Facial Subunit.

    Science.gov (United States)

    Shue, Shirley; Kurlander, David E; Guyuron, Bahman

    2017-08-08

    Fat grafting to the aging face has become an integral component of esthetic surgery. However, the amount of fat to inject to each area of the face is not standardized and has been based mainly on the surgeon's experience. The purpose of this study was to perform a systematic review of injected fat volume to different facial zones. A systematic review of the literature was performed through a MEDLINE search using keywords "facial," "fat grafting," "lipofilling," "Coleman technique," "autologous fat transfer," and "structural fat grafting." Articles were then sorted by facial subunit and analyzed for: author(s), year of publication, study design, sample size, donor site, fat preparation technique, average and range of volume injected, time to follow-up, percentage of volume retention, and complications. Descriptive statistics were performed. Nineteen articles involving a total of 510 patients were included. Rhytidectomy was the most common procedure performed concurrently with fat injection. The mean volume of fat injected to the forehead is 6.5 mL (range 4.0-10.0 mL); to the glabellar region 1.4 mL (range 1.0-4.0 mL); to the temple 5.9 mL per side (range 2.0-10.0 mL); to the eyebrow 5.5 mL per side; to the upper eyelid 1.7 mL per side (range 1.5-2.5 mL); to the tear trough 0.65 mL per side (range 0.3-1.0 mL); to the infraorbital area (infraorbital rim to lower lid/cheek junction) 1.4 mL per side (range 0.9-3.0 mL); to the midface 1.4 mL per side (range 1.0-4.0 mL); to the nasolabial fold 2.8 mL per side (range 1.0-7.5 mL); to the mandibular area 11.5 mL per side (range 4.0-27.0 mL); and to the chin 6.7 mL (range 1.0-20.0 mL). Data on exactly how much fat to inject to each area of the face in facial fat grafting are currently limited and vary widely based on different methods and anatomical terms used. This review offers the ranges and the averages for the injected volume in each zone. This journal requires that authors assign a level of evidence

  17. Water injection profiling by nuclear logging

    International Nuclear Information System (INIS)

    Arnold, D.M.

    1980-01-01

    This invention relates to nuclear logging techniques for determining the volume flow rates and flow directions of injected water moving behind a wellbore casing. The apparatus includes a sonde equipped with a neutron source and dual radiation detectors. Oxygen in the neutron irradiated water is transmitted to 16 N and the resultant primary and Compton scattered gamma rays are detected in two energy windows by both detectors. Count rate data is analysed in terms of the windows to obtain linear flow velocities for water flow within and behind the casing. Volume flow rates are determined for upward and downward flow, and horizontal volume flow into the surrounding formation is calculated. A complete injection profile may thus be obtained. (U.K.)

  18. A randomized clinical trial on comparison of corticosteroid injection with or without splinting versus saline injection with or without splinting in patients with lateral epicondylitis

    Directory of Open Access Journals (Sweden)

    Mohammad Ali Tahririan

    2014-01-01

    Full Text Available Background: Lateral epicondylitis is a common problem affecting 1-3% of the population. There has been much debate about the best treatment modality for this condition. There is, however, no conclusive evidence in support of any of the proposed treatment modalities. In this trial, we have studied the effect of corticosteroid injection (with or without splinting with normal saline injection (with or without splinting. Materials and Methods: In this double-blind, randomized clinical trial, individuals were randomly assigned to either of four treatment groups and received either 40 mg depomedrol injection alone, 40 mg depomedrol injection with splinting, normal saline injection alone, or normal saline injection with splinting. They were evaluated using the visual analog scale (VAS at weeks 2, 4 and 24 and with the Oxford elbow scale (OES at 24 weeks. Results: A total of 79 patients were participated in the study. The corticosteroid injection groups had better pain relief as measured by VAS at 2 and 4 weeks compared with the two saline injection groups. Mean VAS difference at week 0 versus week 2 was 4.5 ± 0.9 and 2.8 ± 0.6 in corticosteroid injection groups and saline injection groups respectively (P < 0.01 but at 24 weeks, there was only moderate benefit reported for the group which received steroid injection and splinting (P < 0.01 compared to the saline injection groups. The saline injection groups reported better improvement in OES scores (20.1 ± 3.7 at the end of the trial compared corticosteroid injection groups (16.1 ± 2.9 (P < 0.05. Conclusion: Our results indicate that despite the clear pain reduction benefit associated with steroid injection in short term, this benefit in comparison with normal saline injection fades by the 24 th week of follow-up.

  19. Effects of viscosity on power and hand injection of iso-osmolar iodinated contrast media through thin catheters.

    Science.gov (United States)

    Zhang, James J; Hogstrom, Barry; Malinak, Jiri; Ikei, Nobuhiro

    2016-05-01

    It can be challenging to achieve adequate vessel opacification during percutaneous coronary interventions when using thin catheters, hand injection, and iso-osmolar contrast media (CM) such as iodixanol (Visipaque™). To explore these limitations and the possibility to overcome them with iosimenol, a novel CM. Three X-ray contrast media with different concentrations were used in this study. A series of in vitro experiments established the relationship between injection pressure and flow rate in angiography catheters under various conditions. The experiments were conducted with power and hand injections and included a double-blind evaluation of user perception. By using hand injection, it was generally not possible to reach a maximum injection pressure exceeding 50 psi. The time within which volunteers were able to complete the injections, the area under the pressure-time curve (AUC), and assessment of ease of injection all were in favor of iosimenol compared with iodixanol, especially when using the 4F thin catheter. Within the pressure ranges tested, the power injections demonstrated that the amount of iodine delivered at a fixed pressure was strongly related to viscosity but unrelated to iodine concentration. There are substantial limitations to the amount of iodine that can be delivered through thin catheters by hand injection when iso-osmolar CM with high viscosity is used. The only viable solution, besides increasing the injection pressure, is to use a CM with lower viscosity, since the cost of increasing the concentration, in terms of increased viscosity and consequent reduction in flow, is too high. Iosimenol, an iso-osmolar CM with lower viscosity than iodixanol might therefore be a better alternative when thinner catheters are preferred, especially when the radial artery is used as the access site. © The Foundation Acta Radiologica 2015.

  20. Factors associated with time between using a drug and injection initiation among people who inject drugs in Kermanshah, Iran.

    Science.gov (United States)

    Noroozi, Mehdi; Farhadi, Mohammad Hassan; Armoon, Bahram; Farhoudian, Ali; Shushtari, Zahra Jorjoran; Sharhani, Asaad; Karimi, Salah Eddin; Sayadnasiri, Mohammad; Rezaei, Omid; Ghiasvand, Hesam

    2018-05-17

    Background The transition from non-injection to injection drug use dramatically increases the risk of transmitting HIV and other blood borne infections including hepatitis B virus (HBV) and hepatitis C virus (HCV). The aim of this study was to explore factors associated with the transition from first illicit drug use to first injection among drug users. Methods Using snowball sampling and convenience sampling through needle and syringe programmes (NSPs), we recruited 500 people who inject drugs (PWID) in Kermanshah, between September and December 2014. Trained interviewers collected data on socio-demographic characteristics, HIV testing and drug-related risk behaviors over the last month prior to interview using a structured questionnaire. Our main outcome variable was first illicit drug use to first injection (TIJ). TIJ was calculated by subtracting age at first drug injection from age of first illicit drug use. Results Overall, the average age at first drug use and injection were 21.4 [standard deviation (SD 5.6)] and 22.8 (SD 8.9), respectively. The average duration of injection was 6.0 (SD 4.6) years. Overall, the mean of TIJ for participants was 1.4 (IQR = 2, 4) years. Age of first injecting drug use negatively correlated with TIJ (R2 = 0.219, p = 0.001). Education level and socioeconomic status (SES), and negatively correlated with TIJ. Conclusion Some demographic factors and drug use characteristics including educational level, SES, knowledge of HIV status, age of initiating drug use, being a poly drug user and using methamphetamine were predictors of the time to transition.

  1. Solid Organic Deposition During Gas Injection Studies

    DEFF Research Database (Denmark)

    Dandekar, Abhijit Y.; Andersen, Simon Ivar; Stenby, Erling Halfdan

    2000-01-01

    Recently a series of first contact miscibility (swelling) experiments have been performed on undersaturated light and heavy oils using LPG rich and methane rich injection gases, in which solid organic deposition was observed. A compositional gradient in the oils during the gas injection process....... The asphaltene content of the different oil samples were determined by the TP 143 method. The standard asphaltenes and the solid organic deposit recovered from the swelling tests were analyzed using FTIR, HPLC-SEC and H-1 NMR. The aim of these analyses is to reveal the molecular nature of the deposits formed...... during the gas injection process in comparison with the standard asphaltenes in order to understand the mechanisms involved in asphaltene deposition....

  2. Preimplantation genetic screening as an alternative to prenatal testing for Down syndrome : preferences of women undergoing in vitro fertilization/intracytoplasmic sperm injection treatment

    NARCIS (Netherlands)

    Twisk, Moniek; Haadsma, Maaike L.; van der Veen, Fulco; Repping, Sjoerd; Mastenbroek, Sebastiaan; Heineman, Maas-Jan; Bossuyt, Patrick M. M.; Korevaar, Johanna C.

    2007-01-01

    Objective: Although the primary goal of preimplantation genetic screening (PGS) is to increase pregnancy rates in women undergoing IVF/intracytoplasmic sperm injection treatment, it has been suggested that it may also be used as an alternative to prenatal testing for Down syndrome. Design: Trade-off

  3. Preimplantation genetic screening as an alternative to prenatal testing for Down syndrome: preferences of women undergoing in vitro fertilization/intracytoplasmic sperm injection treatment

    NARCIS (Netherlands)

    Twisk, Moniek; Haadsma, Maaike L.; van der Veen, Fulco; Repping, Sjoerd; Mastenbroek, Sebastiaan; Heineman, Maas-Jan; Bossuyt, Patrick M. M.; Korevaar, Johanna C.

    2007-01-01

    Objective: Although the primary goal of preimplantation genetic screening (PGS) is to increase pregnancy rates in women undergoing IVF/intracytoplasmic sperm injection treatment, it has been suggested that it may also be used as an alternative to prenatal testing for Down syndrome. Design: Trade-off

  4. Acceptability of rapid oral fluid HIV testing among male injection drug users in Taiwan, 1997 and 2007.

    Science.gov (United States)

    Lyu, Shu-Yu; Morisky, Donald E; Yeh, Ching-Ying; Twu, Shiing-Jer; Peng, Eugene Yu-Chang; Malow, Robert M

    2011-04-01

    Rapid oral fluid HIV testing (rapid oral testing) is in the process of being adapted in Taiwan and elsewhere given its advantages over prior HIV testing methods. To guide this process, we examined the acceptability of rapid oral testing at two time points (i.e., 1997 and 2007) among one of the highest risk populations, male injection drug users (IDUs). For this purpose, an anonymous self-administered survey was completed by HIV-negative IDUs involved in the criminal justice system in 1997 (N (1)=137 parolees) and 2007 (N (2)=106 prisoners). A social marketing model helped guide the design of our questionnaire to assess the acceptability of rapid oral testing. This included assessing a new product, across four marketing dimensions: product, price, promotion, and place. Results revealed that in both 1997 and 2007, over 90% indicated that rapid oral testing would be highly acceptable, particularly if the cost was under US$6, and that a pharmacy would be the most appropriate and accessible venue for selling the rapid oral testing kits. The vast majority of survey respondents believed that the cost of rapid oral testing should be federally subsidized and that television and newspaper advertisements would be the most effective media to advertise for rapid oral testing. Both the 1997 and 2007 surveys suggested that rapid oral HIV testing would be particularly accepted in Taiwan by IDUs after release from the criminal justice system.

  5. Divergent short- and long-term effects of acute stress in object recognition memory are mediated by endogenous opioid system activation.

    Science.gov (United States)

    Nava-Mesa, Mauricio O; Lamprea, Marisol R; Múnera, Alejandro

    2013-11-01

    Acute stress induces short-term object recognition memory impairment and elicits endogenous opioid system activation. The aim of this study was thus to evaluate whether opiate system activation mediates the acute stress-induced object recognition memory changes. Adult male Wistar rats were trained in an object recognition task designed to test both short- and long-term memory. Subjects were randomly assigned to receive an intraperitoneal injection of saline, 1 mg/kg naltrexone or 3 mg/kg naltrexone, four and a half hours before the sample trial. Five minutes after the injection, half the subjects were submitted to movement restraint during four hours while the other half remained in their home cages. Non-stressed subjects receiving saline (control) performed adequately during the short-term memory test, while stressed subjects receiving saline displayed impaired performance. Naltrexone prevented such deleterious effect, in spite of the fact that it had no intrinsic effect on short-term object recognition memory. Stressed subjects receiving saline and non-stressed subjects receiving naltrexone performed adequately during the long-term memory test; however, control subjects as well as stressed subjects receiving a high dose of naltrexone performed poorly. Control subjects' dissociated performance during both memory tests suggests that the short-term memory test induced a retroactive interference effect mediated through light opioid system activation; such effect was prevented either by low dose naltrexone administration or by strongly activating the opioid system through acute stress. Both short-term memory retrieval impairment and long-term memory improvement observed in stressed subjects may have been mediated through strong opioid system activation, since they were prevented by high dose naltrexone administration. Therefore, the activation of the opioid system plays a dual modulating role in object recognition memory. Copyright © 2013 Elsevier Inc. All rights

  6. Once-monthly paliperidone injection for the treatment of schizophrenia

    Directory of Open Access Journals (Sweden)

    Delia Bishara

    2010-09-01

    Full Text Available Delia BisharaPharmacy Department, South London and Maudsley NHS Foundation Trust, London, United KingdomAbstract: Paliperidone palmitate is a new long-acting antipsychotic injection for the treatment of acute and maintenance therapy in schizophrenia. Paliperidone (9-hydroxyrisperidone is the major active metabolite of risperidone and acts at dopamine D2 and serotonin 5HT2A receptors. As with other atypical antipsychotics, it exhibits a high 5HT2A:D2 affinity ratio. It also has binding activity as an antagonist at α1- and α2 adrenergic receptors and H1 histaminergic receptors, but has virtually no affinity for cholinergic receptors. Paliperidone palmitate has been shown to be effective in reducing Positive and Negative Syndrome Scale total scores in four short-term trials in acute schizophrenia. It was also effective as maintenance therapy in a long-term trial in which time to recurrence of symptoms was significantly longer in paliperidone-treated patients compared with placebo. In addition, paliperidone was shown to be noninferior to risperidone long-acting injection in one study, but this noninferiority was not established in another longer study comparing the two drugs. Treatment should be initiated with 234 mg on day 1 and 156 mg on day 8, followed by a recommended monthly maintenance dose of 39–234 mg based on efficacy and tolerability. Paliperidone palmitate is generally well tolerated, although it can cause weight gain and a rise in prolactin levels, which is generally greater in women than in men. Overall, paliperidone palmitate may have advantages over other currently available long-acting injections, and therefore may be a useful alternative for the treatment of schizophrenia, although further long-term trials comparing it with active treatments are warranted.Keywords: paliperidone palmitate, injection, schizophrenia, long-acting

  7. Comparison Between the Two-Injection Technique and the Four-Injection Technique in Axillary Brachial Plexus Block with Articaine.

    Science.gov (United States)

    Ertikin, Aysun; Argun, Güldeniz; Mısırlıoğlu, Mesut; Aydın, Murat; Arıkan, Murat; Kadıoğulları, Nihal

    2017-10-01

    In this study, we aimed to compare axillary brachial plexus block using the two-injection and four-injection techniques assisted with ultrasonography (USG) and nerve stimulator in patients operated for carpal tunnel syndrome with articaine. To evaluate which technique is more effective, we compared the onset time, effectiveness, and duration of block procedures, patient satisfaction, adverse effect of the drug, and complication rates of the motor and sensory blocks. Sixty patients were randomly divided into two groups. A mixture of physiologic serum added to articain with NaHCO 3 (30 mL) was injected into the patients' axilla in both the groups. After the blockage of the musculocutaneous nerve in both the groups, the median nerve in the two-injection group and the median nerve, ulnar nerve, and radial nerve in the four-injection group were blocked. In brachial plexus nerves, sensorial blockage was evaluated with pinprick test, and motor block was evaluated by contraction of the muscles innervated by each nerve. The adverse effects and complications, visual analog scale (VAS) values during the operation, and post-operative patient satisfaction were recorded. Sufficient analgesia and anaesthesia were achieved with no need for an additional local anaesthetics in both the groups. Furthermore, additional sedation requirements were found to be similar in both the groups. A faster rate and a more effective complete block were achieved in more patients from the four-injection group. In the two-injection group, the block could not be achieved for N. radialis in one patient. All other nerves were successfully blocked. Whereas the blockage procedure lasted longer in the four-injection group, the VAS values recorded during the blockage procedure were higher in the four-injection group. No statistical difference was found with regard to patient satisfaction, and no adverse effects and complications were observed in any group. Although the multi-injection method takes more time

  8. The reflectivity, wettability and scratch durability of microsurface features molded in the injection molding process using a dynamic tool tempering system

    Science.gov (United States)

    Kuhn, Sascha; Burr, August; Kübler, Michael; Deckert, Matthias; Bleesen, Christoph

    2011-02-01

    In this paper the replication qualities of periodically and randomly arranged micro-features molded in the injection molding process and their effects on surface properties are studied. The features are molded in PC, PMMA and PP at different mold wall temperatures in order to point out the necessity and profitability of a variotherm mold wall temperature control system. A one-dimensional heat conduction model is proposed to predict the cycle times of the variotherm injection molding processes. With regard to these processes, the molding results are compared to the molded surface feature heights using an atomic force microscope. In addition, the effects of the molded surface features on macroscopic surfaces are characterized in terms of light reflection using a spectrometer and in terms of water wettability by measuring the static contact angle. Furthermore, due to the sensitivity of the surface features on the molded parts, their durability is compared in a scratch test with a diamond tip. This leads to successful implementation in applications in which the optical appearance, in terms of gloss and reflection, and the water repellence, in terms of drag flow and adhesion, are of importance.

  9. The reflectivity, wettability and scratch durability of microsurface features molded in the injection molding process using a dynamic tool tempering system

    International Nuclear Information System (INIS)

    Kuhn, Sascha; Burr, August; Kübler, Michael; Deckert, Matthias; Bleesen, Christoph

    2011-01-01

    In this paper the replication qualities of periodically and randomly arranged micro-features molded in the injection molding process and their effects on surface properties are studied. The features are molded in PC, PMMA and PP at different mold wall temperatures in order to point out the necessity and profitability of a variotherm mold wall temperature control system. A one-dimensional heat conduction model is proposed to predict the cycle times of the variotherm injection molding processes. With regard to these processes, the molding results are compared to the molded surface feature heights using an atomic force microscope. In addition, the effects of the molded surface features on macroscopic surfaces are characterized in terms of light reflection using a spectrometer and in terms of water wettability by measuring the static contact angle. Furthermore, due to the sensitivity of the surface features on the molded parts, their durability is compared in a scratch test with a diamond tip. This leads to successful implementation in applications in which the optical appearance, in terms of gloss and reflection, and the water repellence, in terms of drag flow and adhesion, are of importance.

  10. Testing of GFL Geosiphon; FINAL

    International Nuclear Information System (INIS)

    Steimke, J.L.

    2001-01-01

    A full-scale, transparent replica of a GeoSiphon was constructed in the TFL to test a new concept, using a solar powered vacuum pump to remove accumulated gases from the air chamber. It did not have a treatment cell containing iron filings as do the actual TNX GeoSiphons in the field, but it was accurate in all other respects. The gas generation that is observed in an actual GeoSiphon was simulated by air injection at the inlet of the TFL GeoSiphon. After facility shakedown, three stages of testing were conducted: verification testing, parametric testing and long term testing. In verification testing, the TFL GeoSiphon was used to reproduce a particular test at TNX in which the water flowrate decreased gradually as the result of air accumulation at the crest of a siphon without an air chamber. For this test the vacuum pump was not used and the air chamber was initially filled with air rather than water. Agreement between data from the TNX GeoSiphon and the TFL GeoSiphon was good, which gave confidence that the TFL GeoSiphon was a good hydraulic representation of the TNX GeoSiphon. For the remaining tests, the solar powered vacuum pump and air chamber were used. In parametric testing, steady state runs were made for water flowrates ranging from 1 gpm to 19 gpm, air injection rates ranging from 0 to 77 standard cc/min and outfall line angles ranging from vertical to 60 degrees from vertical. In all cases, the air chamber and vacuum pump removed nearly all of the air and the GeoSiphon operated without problems. In long term testing, the GeoSiphon was allowed to run continuously for 21 days at one set of conditions. During this time the solar cell kept the storage battery fully charged at all times and the control circuit for the vacuum pump operated reliably. The solar panel was observed to have a large excess capacity when used with the vacuum pump. With two changes, the concept of using a solar powered vacuum pump attached to an air chamber should be ready for long

  11. Effect of exhaust gas recirculation (EGR) and multiple injections on diesel soot nano-structure and reactivity

    International Nuclear Information System (INIS)

    Rohani, Behzad; Bae, Choongsik

    2017-01-01

    Highlights: • EGR reduced the nano-structural order, regardless of injection strategy. • EGR reduces both VOF and reactivity, regardless of injection strategy. • Longer dwell time between pilot and main injection increases VOF and reactivity. • With EGR, VOF and reactivity are both reduced and un-affected by injection strategy. • VOF-reactivity correlation (without causality) suggests role of surface roughness. - Abstract: The physio-chemical characteristics of soot particles are of importance with regard to performance of diesel after-treatment systems. In this study, the soot particles generated in a single-cylinder heavy-duty diesel engine are examined in terms of nanostructure, oxidative reactivity and volatile organic fraction (VOF), using thermogravimetric analysis (TGA), X-ray diffraction (XRD), Raman micro-spectroscopy, and high resolution transmission electron microscopy (HRTEM). Five different injection strategies including single injection and multiple injections with various pilot injection amounts and dwell times were tested with and without exhaust gas recirculation (EGR), while combustion phasing, engine speed, and fuel injection quantity was matched for all cases. Results indicate that for the soot produced under EGR condition, nano-structural order (indicated by crystallite size obtained from XRD and AD1/AG resulted from the Raman Analysis) can explain the soot reactivity. However, in the absence of EGR, the reactivity trend cannot be explained by the structural order. It is discussed that a possible reason can be a higher level of in-cylinder oxidation in non-EGR cases (indicated by higher level of surface functional groups) which roughens the soot surface, and enhances the oxidation by increasing the specific soot surface area. It is also found that in the absence of EGR, different injection strategies impact the soot reactivity and VOF content, which can be explained mainly through the level of charge premixed-ness and the in

  12. Safe injection procedures, injection practices, and needlestick ...

    African Journals Online (AJOL)

    Nermine Mohamed Tawfik Foda

    2017-01-10

    Jan 10, 2017 ... sures regarding disposable injection equipment, waste containers, hand hygiene ... injection practices lead to high prevalence of NSSIs in operating rooms. .... guidelines, the availability of training courses to HCWs, and provi-.

  13. Vibration analysis of the Golfech 2 safety injection system

    International Nuclear Information System (INIS)

    Morilhat, P.

    1993-01-01

    The main function of the safety injection system in a PWR plant is to ensure cooling of fuel elements in the event of a loss of coolant accident. The multistage centrifugal pump mounted-on this system induces pressure fluctuations, resulting in dynamic loads on piping. In certain plant units, these loads have caused cracking in the nozzles connected to the safety injection system, whereas in others, no damage has been observed. In order to understand the differences in dynamic behavior observed from one site to another, tests were performed on a real safety injection system, that of Golfech-2. They enabled determination of the modal characteristics of the system and identification of the hydro-acoustic source of the low head safety injection pump. They also enabled assessment of the pressure fluctuation levels in the pump suction and discharge areas as well as the vibratory response of the system when operating under partial and nominal flow conditions. Finally, these test results were used to estimate fatigue damage in the safety injection system. The experimental results will later be used to validate the model of the system undertaken with the piping design code CIRCUS and define the boundary conditions to be taken into account. (author). 6 figs., 2 refs

  14. LABORATORY SCALE STEAM INJECTION TREATABILITY STUDIES

    Science.gov (United States)

    Laboratory scale steam injection treatability studies were first developed at The University of California-Berkeley. A comparable testing facility has been developed at USEPA's Robert S. Kerr Environmental Research Center. Experience has already shown that many volatile organic...

  15. Long-Term Prognosis of Plantar Fasciitis

    DEFF Research Database (Denmark)

    Hansen, Liselotte; Krogh, Thøger Persson; Ellingsen, Torkell

    2018-01-01

    , exercise-induced symptoms, bilateral heel pain, fascia thickness, and presence of a heel spur) could predict long-term outcomes, (3) to assess the long-term ultrasound (US) development in the fascia, and (4) to assess whether US-guided corticosteroid injections induce atrophy of the heel fat pad. Study....... The risk was significantly greater for women (P heel...... regardless of symptoms and had no impact on prognosis, and neither did the presence of a heel spur. Only 24% of asymptomatic patients had a normal fascia on US at long-term follow-up. A US-guided corticosteroid injection did not cause atrophy of the heel fat pad. Our observational study did not allow us...

  16. Long-term follow-up of corticosteroid injection for traumatic olecranon bursitis.

    Science.gov (United States)

    Weinstein, P S; Canoso, J J; Wohlgethan, J R

    1984-01-01

    Forty-seven patients with traumatic olecranon bursitis were evaluated after a mean follow-up of 31 months (range 6 to 62 months). Twenty-two patients treated with bursal aspiration had delayed recovery and no complications of therapy. Twenty-five patients treated with intrabursal injection of 20 mg of triamcinolone hexacetonide had rapid recovery, usually within one week, but suffered complications such as infection (3 cases), skin atrophy (5 cases), and chronic local pain (7 cases). Since spontaneous resolution can be expected, a conservative approach is suggested in the treatment of traumatic olecranon bursitis. Images PMID:6696516

  17. Hydrogen pellet injection device

    International Nuclear Information System (INIS)

    Kanno, Masahiro.

    1992-01-01

    In a hydrogen pellet injection device, a nozzle block having a hydrogen gas supply channel is disposed at the inner side of a main cryogenic housing, and an electric resistor is attached to the block. Further, a nozzle block and a hydrogen gas introduction pipe are attached by way of a thermal insulating spacer. Electric current is supplied to the resistor to positively heat the nozzle block and melt remaining solid hydrogen in the hydrogen gas supply channel. Further, the effect of temperature elevation due to the resistor is prevented from reaching the side of the hydrogen gas introduction pipe by the thermal insulation spacer. That is, the temperature of the nozzle block is directly and positively elevated, to melt the solid hydrogen rapidly. Preparation operation from the injection of the hydrogen pellet to the next injection can be completed in a shorter period of time compared with a conventional case thereby enabling to make the test more efficient. Further, only the temperature of the nozzle block is elevated with no effect of temperature elevation due to the resistor to other components by the thermal insulation flange. (N.H.)

  18. Effect of caudal epidural steroid or saline injection in chronic lumbar radiculopathy: multicentre, blinded, randomised controlled trial

    DEFF Research Database (Denmark)

    Iversen, Trond; Solberg, Tore K; Romner, Bertil

    2011-01-01

    To assess the efficacy of caudal epidural steroid or saline injection in chronic lumbar radiculopathy in the short (6 weeks), intermediate (12 weeks), and long term (52 weeks).......To assess the efficacy of caudal epidural steroid or saline injection in chronic lumbar radiculopathy in the short (6 weeks), intermediate (12 weeks), and long term (52 weeks)....

  19. Subcutaneous Injection of Oxyfluorfen Herbicide to the Forearm: Case Report

    OpenAIRE

    Couceiro, José; Garcia-Portal, Gonzalo; Garcia, Olga

    2017-01-01

    Background  Oxyfluorfen, a commercially available pesticide, commonly used for weed control in crop production, has been studied in terms of its toxicity, its carcinogenic properties, and its teratogenicity. We have found no reports, however, of the effects produced by an oxyfluorfen injection to the upper limb. Methods  We present the case of a 40 years old psychiatric patient, who reportedly injected her forearm accidentally while fumigating her garden. She was treated with irrigation and o...

  20. Emission Constrained Multiple-Pulse Fuel Injection Optimisation and Control for Fuel-Efficient Diesel Engines

    NARCIS (Netherlands)

    Luo, X.; Jager, B. de; Willems, F.P.T.

    2015-01-01

    With the application of multiple-pulse fuel injection profiles, the performance of diesel engines is enhanced in terms of low fuel consumption and low engine-out emission levels. However, the calibration effort increases due to a larger number of injection timing parameters. The difficulty of

  1. Reduction of Altitude Diffuser Jet Noise Using Water Injection

    Science.gov (United States)

    Allgood, Daniel C.; Saunders, Grady P.; Langford, Lester A.

    2011-01-01

    A feasibility study on the effects of injecting water into the exhaust plume of an altitude rocket diffuser for the purpose of reducing the far-field acoustic noise has been performed. Water injection design parameters such as axial placement, angle of injection, diameter of injectors, and mass flow rate of water have been systematically varied during the operation of a subscale altitude test facility. The changes in acoustic far-field noise were measured with an array of free-field microphones in order to quantify the effects of the water injection on overall sound pressure level spectra and directivity. The results showed significant reductions in noise levels were possible with optimum conditions corresponding to water injection at or just upstream of the exit plane of the diffuser. Increasing the angle and mass flow rate of water injection also showed improvements in noise reduction. However, a limit on the maximum water flow rate existed as too large of flow rate could result in un-starting the supersonic diffuser.

  2. High accuracy injection circuit for the calibration of a large pixel sensor matrix

    International Nuclear Information System (INIS)

    Quartieri, E.; Comotti, D.; Manghisoni, M.

    2013-01-01

    Semiconductor pixel detectors, for particle tracking and vertexing in high energy physics experiments as well as for X-ray imaging, in particular for synchrotron light sources and XFELs, require a large area sensor matrix. This work will discuss the design and the characterization of a high-linearity, low dispersion injection circuit to be used for pixel-level calibration of detector readout electronics in a large pixel sensor matrix. The circuit provides a useful tool for the characterization of the readout electronics of the pixel cell unit for both monolithic active pixel sensors and hybrid pixel detectors. In the latter case, the circuit allows for precise analogue test of the readout channel already at the chip level, when no sensor is connected. Moreover, it provides a simple means for calibration of readout electronics once the detector has been connected to the chip. Two injection techniques can be provided by the circuit: one for a charge sensitive amplification and the other for a transresistance readout channel. The aim of the paper is to describe the architecture and the design guidelines of the calibration circuit, which has been implemented in a 130 nm CMOS technology. Moreover, experimental results of the proposed injection circuit will be presented in terms of linearity and dispersion

  3. Optimization of parameters for the inline-injection system at Brookhaven Accelerator Test Facility

    International Nuclear Information System (INIS)

    Parsa, Z.; Ko, S.K.

    1995-01-01

    We present some of our parameter optimization results utilizing code PARMLEA, for the ATF Inline-Injection System. The new solenoid-Gun-Solenoid -- Drift-Linac Scheme would improve the beam quality needed for FEL and other experiments at ATF as compared to the beam quality of the original design injection system. To optimize the gain in the beam quality we have considered various parameters including the accelerating field gradient on the photoathode, the Solenoid field strengths, separation between the gun and entrance to the linac as well as the (type size) initial charge distributions. The effect of the changes in the parameters on the beam emittance is also given

  4. Short-term effect of ultrasound-guided low-molecular-weight hyaluronic acid injection on clinical outcomes and imaging changes in patients with rheumatoid arthritis of the ankle and foot joints. A randomized controlled pilot trial.

    Science.gov (United States)

    Wang, Chien-Chih; Lee, Si-Huei; Lin, Hsiao-Yi; Liu, Fu-Wei; Chiou, Hong-Jen; Chan, Rai-Chi; Chou, Chen-Liang

    2017-11-01

    To determine whether hyaluronic acid (HA) injection into rheumatoid arthritis ankles and feet can achieve improvement in foot function and reduce synovial hyper-vascularization. Forty-four patients with RA having unilateral or bilateral painful ankle and foot involvement (N = 75) were studied. All the patients were randomized to receive HA (N = 40) or lidocaine (LI) (N = 35) injection at 2-week intervals; Clinical assessments were performed using a visual analog scale (VAS) and foot function index (FFI total ) including subscales of pain (FFI pain) before injection at baseline, 4 weeks (first evaluation) and 12 weeks (secondary evaluation). Imaging evaluation based on color Doppler ultrasound (CDUS) and synovitis scores was performed simultaneously. HA injection improved the VAS score (p = .009), FFI pain (p = .041), and FFI total (p = .032) considerably more than LI injections did at the first evaluation. The CDUS values at first evaluation (p = .005) and secondary evaluation (p injections reduced the CDUS values of more than half of the joints (54%, p = .042) while the control group exhibited no change (20%, p = .56). However, HA injection did not reduce the CDUS values more than LI injection did. Regarding the evaluation of synovial hypertrophy, no significant difference was observed between or within the groups in the synovitis scores. HA injection improved short-term foot function and pain reduction. HA injection may have a modest effect in reducing synovial hyper-vascularization. Further large-scale study is warranted to confirm this result.

  5. Stability of penicillin G sodium diluted with 0.9% sodium chloride injection or 5% dextrose injection and stored in polyvinyl chloride bag containers and elastomeric pump containers.

    Science.gov (United States)

    Hossain, Mirza Akram; Friciu, Mihaela; Aubin, Sebastien; Leclair, Grégoire

    2014-04-15

    The stability of penicillin G sodium solutions stored in polyvinyl chloride (PVC) bags or elastomeric pump containers was studied. Test samples were prepared by diluting powdered penicillin G sodium (10 million units/10-mL vial) to solutions of 2,500 or 50,000 units/mL with 0.9% sodium chloride injection or 5% dextrose injection. The preparations were transferred to 250-mL PVC bags and elastomeric pump containers. All samples were prepared in triplicate and stored at 5°C. Chemical stability was measured by a stability-indicating high-performance liquid chromatographic (HPLC) assay and by pH evaluation. Particulate matter was evaluated according to compendial standards using a light-obscuration particle count test. Preparations were visually examined throughout the study. After 21 days of storage, all test samples remained chemically stable, with an HPLC assay recovery value of more than 90% of the initial value. After 28 days, all samples prepared with either diluent and stored in PVC bags, as well as the samples diluted to 2,500 units/mL with sodium chloride injection and stored in elastomeric pump containers, did not meet the recovery acceptance limit. For all test samples, the mean pH consistently decreased during storage, from about 6.4 to about 5.5. Particle counts remained acceptable throughout the study, and no change in appearance was observed. Penicillin G for injection (2,500 and 50,000 units/mL) diluted in 0.9% sodium chloride injection or 5% dextrose injection and stored at 5°C in PVC containers or elastomeric pump containers was physically and chemically stable for a period of at least 21 days.

  6. Study of status of safe injection practice and knowledge regarding injection safety among primary health care workers in Baglung district, western Nepal.

    Science.gov (United States)

    Gyawali, Sudesh; Rathore, Devendra S; Kc, Bhuvan; Shankar, P Ravi

    2013-01-03

    Unsafe injection practices and injection overuse are widespread in developing countries harming the patient and inviting risks to the health care workers. In Nepal, there is a dearth of documented information about injection practices so the present study was carried out: a) to determine whether the selected government health facilities satisfy the conditions for safe injections in terms of staff training, availability of sterile injectable equipment and their proper disposal after use and b) to assess knowledge and attitudes of healthcare workers in these health care facilities with regard to injection safety. A descriptive cross-sectional mixed type (qualitative and quantitative) survey was carried out from 18th May to 16th June 2012. In-depth interviews with the in-charges were conducted using a semi-structured questionnaire. Observation of the health facilities using a structured observation tool was done. The data were analysed manually by summarizing, tabulating and presenting in various formats. The in-charges (eight males, two females) who participated in the study ranged in age from 30 to 50 years with a mean age of 37.8 years. Severe infection followed by pain was the most important cause for injection use with injection Gentamicin being most commonly prescribed. New single use (disposable) injections and auto-disable syringes were used to inject curative drugs and vaccines respectively. Sufficient safety boxes were also supplied to dispose the used syringe. All health care workers had received full course of Hepatitis B vaccine and were knowledgeable about at least one pathogen transmitted through unsafe injection practices. Injection safety management policy and waste disposal guideline was not available for viewing in any of the facilities. The office staff who disposed the bio-medical wastes did so without taking any safety measures. Moreover, none of these staff had received any formal training in waste management. Certain safe injection

  7. Study of status of safe injection practice and knowledge regarding injection safety among primary health care workers in Baglung district, western Nepal

    Directory of Open Access Journals (Sweden)

    Gyawali Sudesh

    2013-01-01

    Full Text Available Abstract Background Unsafe injection practices and injection overuse are widespread in developing countries harming the patient and inviting risks to the health care workers. In Nepal, there is a dearth of documented information about injection practices so the present study was carried out: a to determine whether the selected government health facilities satisfy the conditions for safe injections in terms of staff training, availability of sterile injectable equipment and their proper disposal after use and b to assess knowledge and attitudes of healthcare workers in these health care facilities with regard to injection safety. Methodology A descriptive cross-sectional mixed type (qualitative and quantitative survey was carried out from 18th May to 16th June 2012. In-depth interviews with the in-charges were conducted using a semi-structured questionnaire. Observation of the health facilities using a structured observation tool was done. The data were analysed manually by summarizing, tabulating and presenting in various formats. Results The in-charges (eight males, two females who participated in the study ranged in age from 30 to 50 years with a mean age of 37.8 years. Severe infection followed by pain was the most important cause for injection use with injection Gentamicin being most commonly prescribed. New single use (disposable injections and auto-disable syringes were used to inject curative drugs and vaccines respectively. Sufficient safety boxes were also supplied to dispose the used syringe. All health care workers had received full course of Hepatitis B vaccine and were knowledgeable about at least one pathogen transmitted through unsafe injection practices. Injection safety management policy and waste disposal guideline was not available for viewing in any of the facilities. The office staff who disposed the bio-medical wastes did so without taking any safety measures. Moreover, none of these staff had received any formal

  8. Injection-depth-locking axial motion guided handheld micro-injector using CP-SSOCT.

    Science.gov (United States)

    Cheon, Gyeong Woo; Huang, Yong; Kwag, Hye Rin; Kim, Ki-Young; Taylor, Russell H; Gehlbach, Peter L; Kang, Jin U

    2014-01-01

    This paper presents a handheld micro-injector system using common-path swept source optical coherence tomography (CP-SSOCT) as a distal sensor with highly accurate injection-depth-locking. To achieve real-time, highly precise, and intuitive freehand control, the system used graphics processing unit (GPU) to process the oversampled OCT signal with high throughput and a smart customized motion monitoring control algorithm. A performance evaluation was conducted with 60-insertions and fluorescein dye injection tests to show how accurately the system can guide the needle and lock to the target depth. The evaluation tests show our system can guide the injection needle into the desired depth with 4.12 um average deviation error while injecting 50 nl of fluorescein dye.

  9. Assessment of MRI Contrast Agent Kinetics via Retro-Orbital Injection in Mice: Comparison with Tail Vein Injection.

    Science.gov (United States)

    Wang, Fang; Nojima, Masanori; Inoue, Yusuke; Ohtomo, Kuni; Kiryu, Shigeru

    2015-01-01

    It is not known whether administration of contrast agent via retro-orbital injection or the tail vein route affects the efficiency of dynamic contrast-enhanced magnetic resonance imaging (MRI). Therefore, we compared the effects of retro-orbital and tail vein injection on the kinetics of the contrast agent used for MRI in mice. The same group of nine healthy female mice received contrast agent via either route. An extracellular contrast agent was infused via the tail vein and retro-orbital vein, in random order. Dynamic contrast-enhanced MRI was performed before and after administering the contrast agent. The contrast effects in the liver, kidney, lung, and myocardium were assessed. The average total times of venous puncture and mounting of the injection system were about 10 and 4 min for the tail vein and retro-orbital route, respectively. For all organs assessed, the maximum contrast ratio occurred 30 s after administration and the time course of the contrast ratio was similar with either routes. For each organ, the contrast ratios correlated strongly; the contrast ratios were similar. The retro-orbital and tail vein routes afforded similar results in terms of the kinetics of the contrast agent. The retro-orbital route can be used as a simple efficient alternative to tail vein injection for dynamic contrast-enhanced MRI of mice.

  10. Acupuncture Injection Combined with Electrokinetic Injection for Polydimethylsiloxane Microfluidic Devices

    Directory of Open Access Journals (Sweden)

    Ji Won Ha

    2017-01-01

    Full Text Available We recently reported acupuncture sample injection that leads to reproducible injection of nL-scale sample segments into a polydimethylsiloxane (PDMS microchannel for microchip capillary electrophoresis. The advantages of the acupuncture injection in microchip capillary electrophoresis include capability of minimizing sample loss and voltage control hardware and capability of introducing sample plugs into any desired position of a microchannel. However, the challenge in the previous study was to achieve reproducible, pL-scale sample injections into PDMS microchannels. In the present study, we introduce an acupuncture injection technique combined with electrokinetic injection (AICEI technique to inject pL-scale sample segments for microchip capillary electrophoresis. We carried out the capillary zone electrophoresis (CZE separation of FITC and fluorescein, and the mixture of 10 μM FITC and 10 μM fluorescein was separated completely by using the AICEI method.

  11. Effects of hypertonic dextrose injections in the rabbit carpal tunnel.

    Science.gov (United States)

    Yoshii, Yuichi; Zhao, Chunfeng; Schmelzer, James D; Low, Phillip A; An, Kai-Nan; Amadio, Peter C

    2011-07-01

    This study investigated the effects of different doses of hypertonic dextrose injection on the carpal tunnel subsynovial connective tissue (SSCT) and median nerve in a rabbit model. Thirty-eight New Zealand white rabbits weighing 4.0-4.5 kg were used. One forepaw carpal tunnel was randomly injected with one of five different treatments: saline-single injection; saline-two injections 1 week apart; 10% dextrose-single injection; 20% dextrose-single injection; or 10% dextrose-two injections 1 week apart. Animals were sacrificed at 12 weeks after the initial injection and were evaluated by electrophysiology (EP), SSCT mechanical testing and histology. There were significant increases in the energy absorption of the SSCT in the 10% dextrose-double injection group compared to the saline injection groups. SSCT stiffness was also significantly increased in the 10% dextrose-double injection group compared to the other groups. There was a significant increase in the thickness of the SSCT in the 10% dextrose-double injection group compared to the saline-single injection group and a significant decrease in the nerve short-long diameter ratio in the 10% dextrose-double injection group compared to the saline-single injection group. There were no changes in EP among the groups. SSCT fibrosis is present for up to 12 weeks after dextrose injection; multiple injections have bigger effects, including what appears to be a secondary change in nerve flattening. This model may be useful to study the effects of external fibrosis on nerve morphology and physiology, such as occurs clinically in carpal tunnel syndrome. Copyright © 2011 Orthopaedic Research Society.

  12. Effect of fuel injection pressure and injection timing of Karanja biodiesel blends on fuel spray, engine performance, emissions and combustion characteristics

    International Nuclear Information System (INIS)

    Agarwal, Avinash Kumar; Dhar, Atul; Gupta, Jai Gopal; Kim, Woong Il; Choi, Kibong; Lee, Chang Sik; Park, Sungwook

    2015-01-01

    Highlights: • Effect of FIP on microscopic spray characteristics. • Effect of FIP and SOI timing on CRDI engine performance, emissions and combustion. • Fuel injection duration shortened, peak injection rate increased with increasing FIP. • SMD (D 32 ) and AMD (D 10 ) of fuel droplets decreased for lower biodiesel blends. • Increase in biodiesel blend ratio and FIP, fuel injection duration decreased. - Abstract: In this investigation, effect of 10%, 20% and 50% Karanja biodiesel blends on injection rate, atomization, engine performance, emissions and combustion characteristics of common rail direct injection (CRDI) type fuel injection system were evaluated in a single cylinder research engine at 300, 500, 750 and 1000 bar fuel injection pressures at different start of injection timings and constant engine speed of 1500 rpm. The duration of fuel injection slightly decreased with increasing blend ratio of biodiesel (Karanja Oil Methyl Ester: KOME) and significantly decreased with increasing fuel injection pressure. The injection rate profile and Sauter mean diameter (D 32 ) of the fuel droplets are influenced by the injection pressure. Increasing fuel injection pressure generally improves the thermal efficiency of the test fuels. Sauter mean diameter (D 32 ) and arithmetic mean diameter (D 10 ) decreased with decreasing Karanja biodiesel content in the blend and significantly increased for higher blends due to relatively higher fuel density and viscosity. Maximum thermal efficiency was observed at the same injection timing for biodiesel blends and mineral diesel. Lower Karanja biodiesel blends (up to 20%) showed lower brake specific hydrocarbon (BSHC) and carbon monoxide (BSCO) emissions in comparison to mineral diesel. For lower Karanja biodiesel blends, combustion duration was shorter than mineral diesel however at higher fuel injection pressures, combustion duration of 50% blend was longer than mineral diesel. Up to 10% Karanja biodiesel blends in a CRDI

  13. Long-term effects on biotransformation of labelled choline in different parts of the rat brain induced by single choline injections

    Energy Technology Data Exchange (ETDEWEB)

    Nordberg, A.; Wahlstroem, G.

    1988-01-01

    The long-term effects of single choline (Ch) injections on the uptake and metabolism of a tracer dose of /sup 3/H-Ch were studied in male rats. Choline was administered as a threshold infusion to obtain convulsions 10 and 4 weeks before sacrific (group 1). At a single threshold infusion of choline 4 weeks before sacrifice no convulsions were induced in 50% of the animals in a second group (group 2-) whereas convulsions were induced in the remainder of the animals in this group (group 2+). Group 3 contained control animals. One min. after administration of a tracer dose of /sup 3/H-Ch the animals were sacrificed and examined for /sup 3/H-total activity, /sup 3/H-Ch, /sup 3/H-acetylcholine (/sup 3/H-ACh) and /sup 3/H-phosphorylcholine (/sup 3/-H-PhCh). These activities were determined in three parts of the brain (cortex, striatum, midbrain + medulla oblongata). In the cortex a significant negative correlation between brain weight and /sup 3/H-ACh synthesis was seen in group 1. A comparison between group 2+ and group 2- indicated that induced convulsions were not critical for this effect. In the striatum there was a significant reduction in the total uptake of radioactivity in group 1 and group 2- when values were compared to the control group. Furthermore a significant positive correlation was detected between the concentration of radiolabel and /sup 3/H-ACh synthesis and a negative relationship with the level of /sup 3/H-Ch. In the midbrain preparation the synthesis of /sup 3/H-ACh was reduced in group 1 where a significant negative correlation was found between the average threshold dose of choline and both /sup 3/H-Ach and /sup 3/H-PhCh synthesis. Thus the Ch threshold doses given several weeks before testing seem to have long term effects on the uptake and utilization of a tracer dose of /sup 3/H-Ch in the cortex and striatum.

  14. Comparison of Microbial Community Compositions of Injection and Production Well Samples in a Long-Term Water-Flooded Petroleum Reservoir

    Science.gov (United States)

    Ren, Hong-Yan; Zhang, Xiao-Jun; Song, Zhi-yong; Rupert, Wieger; Gao, Guang-Jun; Guo, Sheng-xue; Zhao, Li-Ping

    2011-01-01

    Water flooding plays an important role in recovering oil from depleted petroleum reservoirs. Exactly how the microbial communities of production wells are affected by microorganisms introduced with injected water has previously not been adequately studied. Using denaturing gradient gel electrophoresis (DGGE) approach and 16S rRNA gene clone library analysis, the comparison of microbial communities is carried out between one injection water and two production waters collected from a working block of the water-flooded Gudao petroleum reservoir located in the Yellow River Delta. DGGE fingerprints showed that the similarities of the bacterial communities between the injection water and production waters were lower than between the two production waters. It was also observed that the archaeal composition among these three samples showed no significant difference. Analysis of the 16S rRNA gene clone libraries showed that the dominant groups within the injection water were Betaproteobacteria, Gammaproteobacteria and Methanomicrobia, while the dominant groups in the production waters were Gammaproteobacteria and Methanobacteria. Only 2 out of 54 bacterial operational taxonomic units (OTUs) and 5 out of 17 archaeal OTUs in the injection water were detected in the production waters, indicating that most of the microorganisms introduced by the injection water may not survive to be detected in the production waters. Additionally, there were 55.6% and 82.6% unique OTUs in the two production waters respectively, suggesting that each production well has its specific microbial composition, despite both wells being flooded with the same injection water. PMID:21858049

  15. Effects of Two Short-Term Desensitization Methods in the Treatment of Test Anxiety

    Science.gov (United States)

    Richardson, Frank C.; Suinn, Richard M.

    1974-01-01

    Accelerated massed desensitization and anxiety management training were compared with standard systematic desensitization in terms of reducing self-reported test anxiety in high test-anxious college students. All three treatments significantly reduced test anxiety as compared with a waiting list control group. (Author)

  16. Efficacy of endoscopic histoacryl injection in treatment of gastric variceal bleeding caused by regional portal hypertension

    Directory of Open Access Journals (Sweden)

    TANG Shanhong

    2015-08-01

    Full Text Available Objective To analyze the efficacy of endoscopic histoacryl injection in the treatment of gastric variceal bleeding caused by regional portal hypertension. Methods The endoscopic features and efficacy of endoscopic histoacryl injection were examined and compared in two groups of patients admitted to our hospital from June 2012 to December 2012. One of the groups included 6 patients with gastric variceal bleeding caused by regional portal hypertension and the other group included 6 patients with gastric variceal bleeding caused by hepatitis B cirrhosis-related portal hypertension. Between-group comparison of categorical data was made by Fisher′s test. Results In patients with regional portal hypertension, five of them had severe isolated gastric varices (IGV and one had severe IGV with mild esophageal varices. All six patients with hepatitis B cirrhosis-related portal hypertension had severe IGV and the endoscopic features were similar to those of patients with regional portal hypertension. Significant differences were observed between the group with regional portal hypertension and the group with hepatitis B cirrhosis related portal hypertension in short-term response rate (1/6 vs 6/6, P=0.015 and long-term response rate (0/6 vs 5/6, P=0.015. Conclusion The gastric varices caused by regional portal hypertension has a fast progression rate and a high bleeding risk. The efficacy of endoscopic histoacryl injection in patients with this type of gastric varices is poor.

  17. Control of Surge in Centrifugal Compressor by Using a Nozzle Injection System: Universality in Optimal Position of Injection Nozzle

    Directory of Open Access Journals (Sweden)

    Toshiyuki Hirano

    2012-01-01

    Full Text Available The passive control method for surge and rotating stall in centrifugal compressors by using a nozzle injection system was proposed to extend the stable operating range to the low flow rate. A part of the flow at the scroll outlet of a compressor was recirculated to an injection nozzle installed on the inner wall of the suction pipe of the compressor through the bypass pipe and injected to the impeller inlet. Two types of compressors were tested at the rotational speeds of 50,000 rpm and 60,000 rpm with the parameter of the circumferential position of the injection nozzle. The present experimental results revealed that the optimum circumferential position, which most effectively reduced the flow rate for the surge inception, existed at the opposite side of the tongue of the scroll against the rotational axis and did not depend on the compressor system and the rotational speeds.

  18. Compressed air injection technique to standardize block injection pressures.

    Science.gov (United States)

    Tsui, Ban C H; Li, Lisa X Y; Pillay, Jennifer J

    2006-11-01

    Presently, no standardized technique exists to monitor injection pressures during peripheral nerve blocks. Our objective was to determine if a compressed air injection technique, using an in vitro model based on Boyle's law and typical regional anesthesia equipment, could consistently maintain injection pressures below a 1293 mmHg level associated with clinically significant nerve injury. Injection pressures for 20 and 30 mL syringes with various needle sizes (18G, 20G, 21G, 22G, and 24G) were measured in a closed system. A set volume of air was aspirated into a saline-filled syringe and then compressed and maintained at various percentages while pressure was measured. The needle was inserted into the injection port of a pressure sensor, which had attached extension tubing with an injection plug clamped "off". Using linear regression with all data points, the pressure value and 99% confidence interval (CI) at 50% air compression was estimated. The linearity of Boyle's law was demonstrated with a high correlation, r = 0.99, and a slope of 0.984 (99% CI: 0.967-1.001). The net pressure generated at 50% compression was estimated as 744.8 mmHg, with the 99% CI between 729.6 and 760.0 mmHg. The various syringe/needle combinations had similar results. By creating and maintaining syringe air compression at 50% or less, injection pressures will be substantially below the 1293 mmHg threshold considered to be an associated risk factor for clinically significant nerve injury. This technique may allow simple, real-time and objective monitoring during local anesthetic injections while inherently reducing injection speed.

  19. ROSA-II test data report, 13

    International Nuclear Information System (INIS)

    1978-07-01

    Results of the ROSA-II test simulating a loss-of-coolant accident (LOCA) in a PWR are presented, including test conditions and interpretations of phenomena observed in test runs 502, 505, 506 and 507. Development tests were performed to find a more effective ECCS injection method than the existing one based on cold leg injection. A combined injection of hot water into upper plenum in early stage of blowdown and subsequent cold water into lower plenum is the most effective method for a cold leg break. A hot leg injection of a low pressure injection system is effective for direct core cooling and early reflooding. The generalization for actual reactors will require analyses with a reliable code. (auth.)

  20. "Injection first": a unique group of injection drug users in Tijuana, Mexico.

    Science.gov (United States)

    Morris, Meghan D; Brouwer, Kimberly C; Lozada, Remedios M; Gallardo, Manuel; Vera, Alicia; Strathdee, Steffanie A

    2012-01-01

    Using baseline data from a study of injection drug users (IDUs) in Tijuana, Mexico (N = 1,052), we identified social and behavioral factors associated with injecting at the same age or earlier than other administration routes of illicit drug use (eg, "injection first") and examined whether this IDU subgroup had riskier drug using and sexual behaviors than other IDUs. Twelve-percent "injected first." Characteristics independently associated with a higher odds of "injection first" included being younger at first injection, injecting heroin as their first drug, being alone at the first injection episode, and having a sexual debut at the same age or earlier as when they initiated drug use; family members' illicit drug use was associated with lower odds of injecting first. When adjusting for age at first injection and number of years injecting, "injection first" IDUs had lower odds of ever overdosing, and ever trading sex. On the other hand, they were less likely to have ever been enrolled in drug treatment, and more commonly obtained their syringes from potentially unsafe sources. In conclusion, a sizable proportion of IDUs in Tijuana injected as their first drug using experience, although evidence that this was a riskier subgroup of IDUs was inconclusive.  Copyright © American Academy of Addiction Psychiatry.

  1. Saline as the Sole Contrast Agent for Successful MRI-guided Epidural Injections

    International Nuclear Information System (INIS)

    Deli, Martin; Fritz, Jan; Mateiescu, Serban; Busch, Martin; Carrino, John A.; Becker, Jan; Garmer, Marietta; Grönemeyer, Dietrich

    2013-01-01

    Purpose. To assess the performance of sterile saline solution as the sole contrast agent for percutaneous magnetic resonance imaging (MRI)-guided epidural injections at 1.5 T. Methods. A retrospective analysis of two different techniques of MRI-guided epidural injections was performed with either gadolinium-enhanced saline solution or sterile saline solution for documentation of the epidural location of the needle tip. T1-weighted spoiled gradient echo (FLASH) images or T2-weighted single-shot turbo spin echo (HASTE) images visualized the test injectants. Methods were compared by technical success rate, image quality, table time, and rate of complications. Results. 105 MRI-guided epidural injections (12 of 105 with gadolinium-enhanced saline solution and 93 of 105 with sterile saline solution) were performed successfully and without complications. Visualization of sterile saline solution and gadolinium-enhanced saline solution was sufficient, good, or excellent in all 105 interventions. For either test injectant, quantitative image analysis demonstrated comparable high contrast-to-noise ratios of test injectants to adjacent body substances with reliable statistical significance levels (p < 0.001). The mean table time was 22 ± 9 min in the gadolinium-enhanced saline solution group and 22 ± 8 min in the saline solution group (p = 0.75). Conclusion. Sterile saline is suitable as the sole contrast agent for successful and safe percutaneous MRI-guided epidural drug delivery at 1.5 T.

  2. Short-term preoperative octreotide treatment for TSH-secreting pituitary adenoma.

    Science.gov (United States)

    Fukuhara, Noriaki; Horiguchi, Kentaro; Nishioka, Hiroshi; Suzuki, Hisanori; Takeshita, Akira; Takeuchi, Yasuhiro; Inoshita, Naoko; Yamada, Shozo

    2015-01-01

    Preoperative control of hyperthyroidism in patients with TSH-secreting pituitary adenomas (TSHoma) may avoid perioperative thyroid storm. Perioperative administration of octreotide may control hyperthyroidism, as well as shrink tumor size. The effects of preoperative octreotide treatment were assessed in a large number of patients with TSHomas. Of 81 patients who underwent surgery for TSHoma at Toranomon Hospital between January 2001 and May 2013, 44 received preoperative short-term octreotide. After excluding one patient because of side effects, 19 received octreotide as a subcutaneous injection, and 24 as a long-acting release (LAR) injection. Median duration between initiation of octreotide treatment and surgery was 33.5 days. Octreotide normalized free T4 in 36 of 43 patients (84%) and shrank tumors in 23 of 38 (61%). Length of octreotide treatment did not differ significantly in patients with and without hormonal normalization (p=0.09) and with and without tumor shrinkage (p=0.84). Serum TSH and free T4 concentrations, duration of treatment, incidence of growth hormone (GH) co-secretion, results of octreotide loading tests, form of administration (subcutaneous injection or LAR), tumor volume, and tumor consistency did not differ significantly in patients with and without hormonal normalization and with and without tumor shrinkage. Short-term preoperative octreotide administration was highly effective for TSHoma shrinkage and normalization of excess hormone concentrations, with tolerable side effects.

  3. Randomised, prospective, non-blinded pilot study comparing the effect of intramuscular steroid injections and intralesional steroid injections in the management of tennis elbow

    Science.gov (United States)

    Tahir, Hasan; Biro, Izolda; Donnelly, Simon; Greenwood, Mandy

    2016-01-01

    Background Tennis elbow is an overuse injury affecting people performing repetitive forearm movements. It is a soft tissue disorder that causes significant disability and pain. The aim of the study was to establish that an intramuscular steroid injection is effective in the short-term pain relief and functional improvement of tennis elbow. The severity of pain at the injection site was monitored to determine whether the intramuscular injection is better tolerated than the intralesional injection. Methods and results 19 patients, who had no treatment for tennis elbow in the preceding 3 months, were recruited from Whipps Cross University Hospital, London, and were randomised to receive either 80 mg of intramuscular Depo-Medrone or 40 mg of intralesional Depo-Medrone injection. Blinding proved difficult as the injection sites differed and placebo arms were not included in the study. A Patient-Rated Tennis Elbow Evaluation (PRTEE) Questionnaire and a 10-point Likert scale were used to assess primary outcome. Six weeks after the treatment, there was a reduction in pain, improvement in function and total PRTEE scores in both intramuscular and intralesional groups (p=0.008) using a 95% CI for mean treatment difference of −26 to +16 points. A statistically significant result (p=0.001) in favour of intramuscular causing less pain at the injection site was noted. Conclusion Non-inferiority of intramuscular to intralesional injections was not confirmed; however, the intramuscular injection proved to be effective in reducing tennis elbow-related symptoms and was found less painful at the site of injection at the time of administration. Trial registration number EUDRACT Number: 2010-022131-11. REC Number: 10/H0718/76 (NRES, Central London REC 1). PMID:28879024

  4. TASKA-M - a low cost, near term tandem mirror device for fusion technology testing

    International Nuclear Information System (INIS)

    Badger, B.; Corradini, M.L.; El-Guebaly, L.; Emmert, G.A.; Kulcinski, G.L.; Larsen, E.M.; Maynard, C.W.; Perkins, L.J.; Peterson, R.R.; Plute, K.E.; Santarius, J.F.; Sawan, M.E.; Scharer, J.E.; Sviatoslavsky, I.N.; Sze, D.K.; Vogelsang, W.F.; Wittenberg, L.J.; Leppelmeier, G.W.; Grover, J.M.; Opperman, E.K.; Vogel, M.A.; Borie, E.; Taczanowski, S.; Arendt, F.; Dittrich, H.G.; Fett, T.; Haferkamp, B.; Heinz, W.; Hoelzchen, E.; Kleefeldt, K.; Klingelhoefer, R.; Komarek, P.; Kuntze, M.; Leiste, H.G.; Link, W.; Malang, S.; Manes, B.M.; Maurer, W.; Michael, I.; Mueller, R.A.; Neffe, G.; Schramm, K.; Suppan, A.; Weinberg, D.

    1984-04-01

    TASKA-M (Modifizierte Tandem Spiegelmaschine Karlsruhe) is a study of a dedicated fusion technology device based on the mirror principle, in continuation of the 1981/82 TASKA study. The main objective is to minimize cost while retaining key requirements of neutron flux and fluence for blanket and material development and for component testing in a nuclear environment. Direct costs are reduced to about 400 M$ by dropping reactor-relevant aspects not essential to technology testing: No thermal barrier and electrostatic plugging of the plasma; fusion power of 7 MW at an injected power of 44 MW; tritium supply from external sources. All technologies for operating the machine are expected to be available by 1990; the plasma physics relies on microstabilization in a sloshing ion population. (orig.) [de

  5. Injection practices in a metropolis of North India: perceptions, determinants and issues of safety.

    Science.gov (United States)

    Kotwal, A; Priya, R; Thakur, R; Gupta, V; Kotwal, J; Seth, T

    2004-08-01

    At least 50 percent of the injections administered each year are unsafe, more particularly in developing countries, posing serious health risks. An initial assessment to describe injection practices; their determinants and adverse effects can prevent injection-associated transmission of blood borne pathogens by reducing injection frequency and adoption of safe injection practices. To assess the injection practices in a large metropolitan city encompassing varied socio-cultural scenarios. STUDY SETTING AND DESIGN: Field based cross sectional survey covering urban non-slum, slum and peri-urban areas of a large metropolitan city. Injection prescribers, providers and community members selected by random sampling from the study areas. Pre tested questionnaires assessed knowledge and perceptions of study subjects towards injections and their possible complications. Observation of the process of injection and prescription audit also carried out. MS Access for database and SPSS ver 11 for analysis. Point estimates, 95% confidence intervals, Chi Square, t test, one-way ANOVA. The per capita injection rate was 5.1 per year and ratio of therapeutic to immunization injections was 4.4:1. Only 22.5%of injections were administered with a sterile syringe and needle. The level of knowledge about HIV and HBV transmission by unsafe injections was satisfactory amongst prescribers and community, but inadequate amongst providers. HCV was known to a very few in all the groups. The annual incidence of needle stick injuries among providers was quite high. A locally relevant safe injection policy based on multi disciplinary approach is required to reduce number of injections, unsafe injections and their attendant complications.

  6. Commissioning of the LHCb Silicon Tracker using data from the LHC injection tests

    CERN Document Server

    Knecht, M; Blanc, F; Bettler, M-O; Conti, G; Fave, V; Frei, R; Gauvin, N; Haefeli, G; Keune, A; Luisier, J; Muresan, R; Nakada, T; Needham, M; Nicolas, L; Perrin, A; Potterat, C; Schneider, O; Tran, M; Bauer, C; Britsch, M; Hofmann, W; Maciuc, F; Schmelling, M; Voss, H; Anderson, J; Buechler, A; Chiapolini, N; Hangartner, V; Salzmann, C; Steiner, S; Steinkamp, O; Van Tilburg, J; Tobin, M; Vollhardt, A; Adeva, B; Fungueiri no Pazos, J; Gallas, A; Pazos-Alvarez, A; Pérez-Trigo, E; Pló-Casasus, M; Rodriguez Perez, P; Saborido, J; Vázquez, P; Iakovenko, V; Okhrimenko, O; Pugatch, V

    2011-01-01

    LHCb is a single-arm forward spectrometer dedicated to the study of the CP-violation and rare decays in the b-quark sector. An efficient and high precision tracking system is a key requirement of the experiment. The LHCb Silicon Tracker Project consists of two sub-detectors that make use of silicon micro-strip technology: the Tracker Turicensis located upstream of the spectrometer magnet and the Inner Tracker which covers the innermost part of the tracking stations after the magnet. In total an area of 12 m^2 is covered by silicon. In September 2008 and June 2009, injection tests from the SPS to the LHC were performed. Bunches of order 5x10^9 protons were dumped onto a beam stopper (TED) located upstream of LHCb. This produced a spray of ~10 GeV muons in the LHCb detector. Though the occupancy in this environment is relatively large, these TED runs have allowed a first space and time alignment of the tracking system. Results of these studies together and the overall detector performance obtained in the TED ru...

  7. Micro Injection Molding of Thin Walled Geometries with Induction Heating System

    DEFF Research Database (Denmark)

    Menotti, Stefano; Hansen, Hans Nørgaard; Bissacco, Giuliano

    2014-01-01

    To eliminate defects and improve the quality of molded parts, increasing the mold temperature is one of the applicable solutions. A high mold temperature can increase the path flow of the polymer inside the cavity allowing reduction of the number of injection points, reduction of part thickness...... and moulding of smaller and more complex geometries. The last two aspects are very important in micro injection molding. In this paper a new embedded induction heating system is proposed and validated. An experimental investigation was performed based on a test geometry integrating different aspect ratios...... of small structures. ABS was used as material and different combinations of injection velocity, pressure and mold temperature were tested. The replicated test objects were measured by means of an optical CMM machine. On the basis of the experimental investigation the efficacy of the embedded induction...

  8. Evaluation of performance, safety, subject acceptance, and compliance of a disposable autoinjector for subcutaneous injections in healthy volunteers.

    Science.gov (United States)

    Berteau, Cecile; Schwarzenbach, Florence; Donazzolo, Yves; Latreille, Mathilde; Berube, Julie; Abry, Herve; Cotten, Joël; Feger, Celine; Laurent, Philippe E

    2010-10-05

    A disposable autoinjector was developed for subcutaneous (SC) self-injection by patients with chronic diseases. To verify its performance and evaluate its acceptance, a clinical study was conducted in healthy volunteers, comparing SC injections performed by subjects using the autoinjector with SC injections performed by nurses using a syringe. This was a randomized, single-center, crossover study comparing SC self-injection using an autoinjector with SC nurse-administered injection using a syringe. Two volumes (0.2 mL and 1 mL) were injected into healthy volunteers. Study objectives included assessment of the accuracy and consistency of the volume injected by the injection systems, and skin reaction and pain associated with the injection. The fluid depot in the SC tissue layer was evaluated by ultrasound. Subject acceptance was evaluated using questionnaires on attitudes and emotions towards the injection technique, and challenged by seeking the subjects' preferred system for a final study injection or future treatment. A total of 960 injections (480 with autoinjector, 480 with syringe) were performed in 40 subjects. There were no significant differences in mean fluid leakage and injected volumes between the systems. Pain associated with the injection was significantly lower with the auto-injector than with the syringe. Local skin reaction at the injection site was overall satisfactory. Injections were appropriately performed by all subjects. At study end, all 40 subjects preferred the autoinjector for a final study injection and for future treatment. This study indicated that the autoinjector used by the subject was similar to a syringe used by a nurse in terms of performance and safety in administering the injections, and better in terms of pain, overall acceptance, and preference.

  9. Centrifugal Compressor Surge Margin Improved With Diffuser Hub Surface Air Injection

    Science.gov (United States)

    Skoch, Gary J.

    2002-01-01

    Aerodynamic stability is an important parameter in the design of compressors for aircraft gas turbine engines. Compression system instabilities can cause compressor surge, which may lead to the loss of an aircraft. As a result, engine designers include a margin of safety between the operating line of the engine and the stability limit line of the compressor. The margin of safety is typically referred to as "surge margin." Achieving the highest possible level of surge margin while meeting design point performance objectives is the goal of the compressor designer. However, performance goals often must be compromised in order to achieve adequate levels of surge margin. Techniques to improve surge margin will permit more aggressive compressor designs. Centrifugal compressor surge margin improvement was demonstrated at the NASA Glenn Research Center by injecting air into the vaned diffuser of a 4:1-pressure-ratio centrifugal compressor. Tests were performed using injector nozzles located on the diffuser hub surface of a vane-island diffuser in the vaneless region between the impeller trailing edge and the diffuser-vane leading edge. The nozzle flow path and discharge shape were designed to produce an air stream that remained tangent to the hub surface as it traveled into the diffuser passage. Injector nozzles were located near the leading edge of 23 of the 24 diffuser vanes. One passage did not contain an injector so that instrumentation located in that passage would be preserved. Several orientations of the injected stream relative to the diffuser vane leading edge were tested over a range of injected flow rates. Only steady flow (nonpulsed) air injection was tested. At 100 percent of the design speed, a 15-percent improvement in the baseline surge margin was achieved with a nozzle orientation that produced a jet that was bisected by the diffuser vane leading edge. Other orientations also improved the baseline surge margin. Tests were conducted at speeds below the

  10. Safe injection procedures, injection practices, and needlestick ...

    African Journals Online (AJOL)

    Nermine Mohamed Tawfik Foda

    2017-01-10

    Jan 10, 2017 ... Background: Of the estimated 384,000 needle-stick injuries occurring in hospitals each year, 23% occur in surgical settings. This study was conducted to assess safe injection procedures, injection practices, and circumstances contributing to needlestick and sharps injures (NSSIs) in operating rooms.

  11. Long term test-retest reliability of Oswestry Disability Index in male office workers.

    Science.gov (United States)

    Irmak, Rafet; Baltaci, Gul; Ergun, Nevin

    2015-01-01

    The Oswestry Disability Index (ODI) is one of the most common condition specific outcome measures used in the management of spinal disorders. But there is insufficient study on healthy populations and long term test-retest reliability. This is important because healthy populations are often used for control groups in low back pain interventions, and knowing the reliability of the controls affects the interpretation of the findings of these studies. The purpose of this study is to determine the long term test-retest reliability of ODI in office workers. Participants who have no chronic low back pain history were included in study. Subjects were assessed by the Turkish-ODI 2.0 (e-forms) on 1st, 2nd, 4th, 8th, 15th, 30th days to determine the stability of ODI scores over time. The study began with 58 (12 female, 46 male) participants. 36 (3 female, 33 male) participated for the full 30 days. Kolmogorov-Smirnov and Friedman tests were used. Test-retest reliability was evaluated by using nonparametric statistics. All tests were done by using SPSS-11. There was no statistically significant difference among the median scores of each day. (χ= 6.482, p >  0.05). The difference between median score of the days with 1st day was neither statistically nor clinically significant. ODI has long term test re-test reliability in healthy subjects over a 1 month time interval.

  12. Small-Scale Testing Rig for Long-Term Cyclically Loaded Monopiles in Cohesionless Soil

    DEFF Research Database (Denmark)

    Roesen, Hanne Ravn; Ibsen, Lars Bo; Andersen, Lars Vabbersgaard

    2012-01-01

    , and the period of the cyclic loading. However, the design guidance on these issues is limited. Thus, in order to investigate the pile behaviour for cyclically long-term loaded monopiles, a test setup for small-scale tests in saturated dense cohesionless soil is constructed and presented in here. The cyclic...... loading is applied mechanically by means of a testing rig, where the important input parameters: mean level, amplitude, number of cycles, and period of the loading can be varied. The results from a monotonic and a cyclic loading test on an open-ended aluminium pile with diameter = 100 mm and embedded...... length = 600 mm proves that the test setup is capable of applying the cyclic long-term loading. The plastic deformations during loading depend not only on the loading applied but also of the relative density of the soil and, thus, the tests are carried out with relative densities of 77-88%, i.e. similar...

  13. The effect of hot water injection on sandstone permeability

    DEFF Research Database (Denmark)

    Rosenbrand, Esther; Haugwitz, Christian; Jacobsen, Peter Sally Munch

    2014-01-01

    Seasonal energy storage can be achieved by hot water injection in geothermal sandstone aquifers. We present an analysis of literature data in combination with new short-term flow through permeability experiments in order to address physical and physico-chemical mechanisms that can alter...

  14. LHI (low head safety injection) emergency cooling pump test for the EPR trademark in operation with solid matter loaded water

    International Nuclear Information System (INIS)

    Ganzmann, I.; Schulte, C.

    2010-01-01

    Emergency cooling pumps are essential and indispensable components of the NPP safety philosophy. In case of a loss-of coolant accident solid matter (debris: fibrous insulation material, concrete dust, pigment particles) might be released into the coolant, LHSI (low head safety injection) pumps have to ensure their performance capacity for a certain amount of debris without damage or loss of power. The authors describe the development of a test facility. The LHSI was tested in continuous operation over a time period of 14 days with a debris content of 1500 ppm (90% mineral wool fibers, 3% concrete dust, 3% pigment particles, 4% microporous insulation material). The pump did not show any damage or loss of hydraulic power. Further tests including thermoshock conditions (temperature changes of 160 C) are planned.

  15. Pharmacy practice and injection use in community pharmacies in Pokhara city, Western Nepal.

    Science.gov (United States)

    Gyawali, Sudesh; Rathore, Devendra Singh; Adhikari, Kishor; Shankar, Pathiyil Ravi; K C, Vikash Kumar; Basnet, Suyog

    2014-04-28

    Community pharmacies in Nepal serve as the first point of contact for the public with the health care system and provide many services, including administering injections. However, there is a general lack of documented information on pharmacy practice and injection use in these pharmacies. This study aims to provide information about pharmacy practice in terms of service and drug information sources, and injection use, including the disposal of used injection equipment. A mixed method, cross-sectional study was conducted in 54 community pharmacies in Pokhara city. Data was collected using a pre-tested, semi-structured questionnaire, and also by the direct observation of pharmacy premises. Interviews with pharmacy supervisors (proprietors) were also conducted to obtain additional information about certain points. Interviews were carried out with 54 pharmacy supervisors/proprietors (47 males and 7 females) with a mean age and experience of 35.54 and 11.73 years, respectively. Approximately a half of the studied premises were operated by legally recognized pharmaceutical personnel, while the remainder was run by people who did not have the legal authority to operate pharmacies independently. About a quarter of pharmacies were providing services such as the administration of injections, wound dressing, and laboratory and consultation services in addition to medicine dispensing and counseling services. The 'Current Index of Medical Specialties' was the most commonly used source for drug information. Almost two-thirds of patients visiting the pharmacies were dispensed medicines without a prescription. Tetanus Toxoid, Depot-Medroxy Progesterone Acetate, and Diclofenac were the most commonly-used/administered injections. Most of the generated waste (including sharps) was disposed of in a municipal dump without adhering to the proper procedures for the disposal of hazardous waste. Community pharmacies in Pokhara offer a wide range of services including, but not limited to

  16. Development of Technique for Testing the Long-Term Stability of Silicon Microstrip Detectors

    International Nuclear Information System (INIS)

    Kosinov, A.V.; Maslov, N.I.; Naumov, S.V.; Ovchinnik, V.D.; Starodubtsev, A.F.; Vasiliev, G.P.; Yalovenko, V.I.; Bosisio, L.

    2006-01-01

    An automatic multi-channel set-up prototype for simultaneous testing of the Long-Term Stability (LTS) of more than ten detectors is described. The Inner Tracking System of the ALICE experiment will include about two thousand Double-sided Microstrip Detectors (DSMD). Efficient automatic measurement techniques are crucial for the LTS test, because the corresponding test procedure should be performed on each detector and requires long time, at least two days. By using special adapters for supporting and connecting the bare DSMDs, failing detectors can be screened out before module assembly, thus minimizing the cost. Automated probe stations developed for a special purpose or for microelectronics industry are used for measuring physical static DSMD characteristics and check good-to-bad elements ratio for DSMD. However, automated (or semi-automatic)test benches for studying LTS or testing DSMD long-term stability before developing a detecting module are absent

  17. Economics of water injected air screw compressor systems

    Science.gov (United States)

    Venu Madhav, K.; Kovačević, A.

    2015-08-01

    There is a growing need for compressed air free of entrained oil to be used in industry. In many cases it can be supplied by oil flooded screw compressors with multi stage filtration systems, or by oil free screw compressors. However, if water injected screw compressors can be made to operate reliably, they could be more efficient and therefore cheaper to operate. Unfortunately, to date, such machines have proved to be insufficiently reliable and not cost effective. This paper describes an investigation carried out to determine the current limitations of water injected screw compressor systems and how these could be overcome in the 15-315 kW power range and delivery pressures of 6-10 bar. Modern rotor profiles and approach to sealing and cooling allow reasonably inexpensive air end design. The prototype of the water injected screw compressor air system was built and tested for performance and reliability. The water injected compressor system was compared with the oil injected and oil free compressor systems of the equivalent size including the economic analysis based on the lifecycle costs. Based on the obtained results, it was concluded that water injected screw compressor systems could be designed to deliver clean air free of oil contamination with a better user value proposition than the oil injected or oil free screw compressor systems over the considered range of operations.

  18. Experiment on performance of upper head injection system with ROSA-II

    International Nuclear Information System (INIS)

    1978-05-01

    Of the total 10 ROSA-II/UHI performance tests, 6 were reported previously. The rest are presented and discussion is made on the effects of heat generation in the core and UHI injection and repeatability of experiments. In addition, the following are described: (1) Pressure spikes observed in the upper head after sudden stoppage of UHI injection, and (2) discharge flow oscillation possibly due to UHI water injection into the upper plenum. (auth.)

  19. New pellet production and acceleration technologies for high speed pellet injection system 'HIPEL' in large helical device

    International Nuclear Information System (INIS)

    Viniar, I.; Sudo, S.

    1994-12-01

    New technologies of pellet production and acceleration for fueling and diagnostics purposes in large thermonuclear reactors are proposed. The technologies are intended to apply to the multiple-pellet injection system 'HIPEL' for Large Helical Device of NIFS in Japan. The pellet production technology has already been tested in a pipe-gun type pellet injector. It will realize the repeating pellet injection by means of decreasing of the pellet formation time into the pipe-gun barrel. The acceleration technology is based upon a new pump tube operation in two-stage gas gun and also upon a new conception of the allowable pressure acting on a pellet into a barrel. Some preliminary estimations have been made, and principles of a pump tube construction providing for a reliable long term operation in the repeating mode without any troubles from a piston are proposed. (author)

  20. Test Particle Simulations of Electron Injection by the Bursty Bulk Flows (BBFs) using High Resolution Lyon-Feddor-Mobarry (LFM) Code

    Science.gov (United States)

    Eshetu, W. W.; Lyon, J.; Wiltberger, M. J.; Hudson, M. K.

    2017-12-01

    Test particle simulations of electron injection by the bursty bulk flows (BBFs) have been done using a test particle tracer code [1], and the output fields of the Lyon-Feddor-Mobarry global magnetohydro- dynamics (MHD) code[2]. The MHD code was run with high resolu- tion (oct resolution), and with specified solar wind conditions so as to reproduce the observed qualitative picture of the BBFs [3]. Test par- ticles were injected so that they interact with earthward propagating BBFs. The result of the simulation shows that electrons are pushed ahead of the BBFs and accelerated into the inner magnetosphere. Once electrons are in the inner magnetosphere they are further energized by drift resonance with the azimuthal electric field. In addition pitch angle scattering of electrons resulting in the violation conservation of the first adiabatic invariant has been observed. The violation of the first adiabatic invariant occurs as electrons cross a weak magnetic field region with a strong gradient of the field perturbed by the BBFs. References 1. Kress, B. T., Hudson,M. K., Looper, M. D. , Albert, J., Lyon, J. G., and Goodrich, C. C. (2007), Global MHD test particle simulations of ¿ 10 MeV radiation belt electrons during storm sudden commencement, J. Geophys. Res., 112, A09215, doi:10.1029/2006JA012218. Lyon,J. G., Fedder, J. A., and Mobarry, C.M., The Lyon- Fedder-Mobarry (LFM) Global MHD Magnetospheric Simulation Code (2004), J. Atm. And Solar-Terrestrial Phys., 66, Issue 15-16, 1333- 1350,doi:10.1016/j.jastp. Wiltberger, Merkin, M., Lyon, J. G., and Ohtani, S. (2015), High-resolution global magnetohydrodynamic simulation of bursty bulk flows, J. Geophys. Res. Space Physics, 120, 45554566, doi:10.1002/2015JA021080.

  1. Long-Term Capital Goods Importation and Minimum Wage Relationship in Turkey: Bounds Testing Approach

    Directory of Open Access Journals (Sweden)

    Tastan Serkan

    2015-04-01

    Full Text Available In order to examine the long-term relationship between capital goods importation and minimum wage, autoregressive distributed lag (ARDL bounds testing approach to the cointegration is used in the study. According to bounds test results, a cointegration relation exists between the capital goods importation and the minimum wage. Therefore an ARDL(4,0 model is estimated in order to determine the long and short term relations between variables. According to the empirical analysis, there is a positive and significant relationship between the capital goods importation and the minimum wage in Turkey in the long term. A 1% increase in the minimum wage leads to a 0.8% increase in the capital goods importation in the long term. The result is similar for short term coefficients. The relationship observed in the long term is preserved in short term, though in a lower level. In terms of error correction model, it can be concluded that error correction mechanism works as the error correction term is negative and significant. Short term deviations might be resolved with the error correction mechanism in the long term. Accordingly, approximately 75% of any deviation from equilibrium which might arise in the previous six month period will be resolved in the current six month period. This means that returning to long term equilibrium progresses rapidly.

  2. Data report for ROSA-IV LSTF gravity-driven safety injection experiment run SB-CL-27

    International Nuclear Information System (INIS)

    Yonomoto, Taisuke; Saitou, Seishi; Kuroda, Takeshi

    1994-03-01

    Experimental data are presented for the passive injection test, Run SB-CL-27, conducted at the ROSA-IV Large Scale Test Facility (LSTF) on September 17, 1992. This experiment simulated thermal-hydraulic behavior of a gravity-driven, passive safety injection system during a small-break loss-of-coolant accident (LOCA) in a pressurized water reactor (PWR). The injection system consisted of a gravity-driven injection tank, located above the reactor vessel, with connecting lines. The tank was initially filled with water of room temperature at the same pressure as the pressurizer. The connecting lines to the cold leg and to the vessel downcomer were opened at the test initiation. Then, a natural circulation flow developed in the loop which was formed by these lines and the injection tank. The hot water in the cold leg circulated into the upper part of tank and accumulated there causing a significant thermal stratification. This thermal stratification prevented direct-contact condensation of steam from occurring during the subsequent tank drain-down phase. Therefore, no condensation-induced depressurization of the tank, affecting adversely the injection performance, occurred. (author)

  3. Intramuscular adrenaline does not reduce the incidence of respiratory distress and hypoglycaemia in neonates delivered by elective caesarean section at term

    DEFF Research Database (Denmark)

    Pedersen, Pernille; Avlund, O L; Pedersen, B L

    2008-01-01

    AIM: To test whether intramuscular injection of 30 microg adrenaline decreased the incidence of respiratory distress and hypoglycaemia in term infants delivered by elective caesarean section before active labour. METHOD: The study was randomised and double-blinded. A total of 270 neonates were...

  4. Ring current energy injection rate and solar wind-magnetosphere energy coupling

    International Nuclear Information System (INIS)

    Lee, L.C.; Kan, J.R.; Akasofu, S.-I.

    1982-01-01

    The purpose of this paper is to (i) formulate the ring current injection rate Usub(R) in terms of phisub(CT) (cross-tail potential drop) by assuming that the ring current formation is a direct consequence of an enhanced convection, (ii) examine the relationship between the injection rate Usub(R) and the power transferred from the solar wind to the magnetosphere and (iii) demonstrate that an enhanced convection indeed leads to the formation of the ring current. (author)

  5. Usefulness of fluoroscopy-guided intra-articular injection of the knee

    Energy Technology Data Exchange (ETDEWEB)

    Myung, Jae Sung; Lee, Joon Woo [Seoul National University Bundang Hospital, Seongnam (Korea, Republic of); Lee, Ji Yeon [Kangwon National University College of Medicine, Chuncheon (Korea, Republic of)] (and others)

    2007-06-15

    To determine the accuracy of the intra-articular location of hyaluronic acid injection using a blind approach and to establish the usefulness of fluoroscopy-guided intra-articular injection. A fluoroscopy unit was used for 368 intra-articular injections of hyaluronic acid to 93 knees in 65 patients. Initially, blind needle positioning was conducted on the fluoroscopy table. The failure rate of the blind approach among the 368 injections was evaluated, and a relationship between the Kellgren-Lawrence grade (K-L grade) and the incidence of repeated failures using the blind approach was determined for injections to 52 knees in 37 patients who received a complete cycle of injections (five consecutive injections with a one-week interval between injections). Using a blind approach, 298 of 368 trials (81.2%) resulted in a needle tip being placed in an intra-articular location, while 70 of 368 trials resulted in an extra-articular placement of the needle tip. Among 52 knees to which a complete cycle of injection (five consecutive injections with a one-week interval between injections) was administered, repeated failure of intra-articular placement using the blind approach was seen for 18 knees (34.6%); a more severe K-L grade assigned was associated with a higher rate of repeated failure. However, the trend was not statistically significant based on the Chi-squared test ({rho} value = 0.14). Fluoroscopy-guided needle placement may be helpful to ensure therapeutic intra-articular injection of the knee.

  6. Usefulness of fluoroscopy-guided intra-articular injection of the knee

    International Nuclear Information System (INIS)

    Myung, Jae Sung; Lee, Joon Woo; Lee, Ji Yeon

    2007-01-01

    To determine the accuracy of the intra-articular location of hyaluronic acid injection using a blind approach and to establish the usefulness of fluoroscopy-guided intra-articular injection. A fluoroscopy unit was used for 368 intra-articular injections of hyaluronic acid to 93 knees in 65 patients. Initially, blind needle positioning was conducted on the fluoroscopy table. The failure rate of the blind approach among the 368 injections was evaluated, and a relationship between the Kellgren-Lawrence grade (K-L grade) and the incidence of repeated failures using the blind approach was determined for injections to 52 knees in 37 patients who received a complete cycle of injections (five consecutive injections with a one-week interval between injections). Using a blind approach, 298 of 368 trials (81.2%) resulted in a needle tip being placed in an intra-articular location, while 70 of 368 trials resulted in an extra-articular placement of the needle tip. Among 52 knees to which a complete cycle of injection (five consecutive injections with a one-week interval between injections) was administered, repeated failure of intra-articular placement using the blind approach was seen for 18 knees (34.6%); a more severe K-L grade assigned was associated with a higher rate of repeated failure. However, the trend was not statistically significant based on the Chi-squared test (ρ value = 0.14). Fluoroscopy-guided needle placement may be helpful to ensure therapeutic intra-articular injection of the knee

  7. Glans Penis Augmentation Using Hyaluronic Acid Gel as an Injectable Filler

    Science.gov (United States)

    Kwak, Tae Il; Kim, Je Jong

    2015-01-01

    Glans penis augmentation (GPA) has received little attention from experts despite the existence of a subset of patients who may be dissatisfied with a small glans or poor tumescence of the glans during erection. Recently, GPA using an injectable filler or implantation of a graft or filler has been developed. Despite a demanding injection technique and inevitable uneven undulation of the glandular surface, GPA using injectable hyaluronic acid (HA) gel is a novel and useful therapy and an effective and safe procedure for soft tissue enhancement. For long-term presence of implants, timed supplementation can be used similar to that for fascial plasty. In complications such as mucosal necrosis of the glans penis, most cases occur from the use of non-HA gel or an unpurified form and misunderstanding of the management protocol for immediate side effects. Currently, GPA using injectable HA gel is not recommended in the International Society for Sexual Medicine guideline due to possible sensory loss. In a 5-year long-term follow-up of GPA by subcutaneous injection of HA gel, the residual volume of implants decreased by 15% of the maximal glandular circumference, but was still effective for alleviating the hypersensitivity of the glans penis in premature ejaculation patients. For efficacy in premature ejaculation, selection of appropriate candidates is the most important factor for success. GPA does not harm erectile function and is less invasive and irreversible compared to dorsal neurectomy. To refine the procedure, more interest and well-designed studies are required for the establishment of the procedure. PMID:26331121

  8. Glans Penis Augmentation Using Hyaluronic Acid Gel as an Injectable Filler.

    Science.gov (United States)

    Moon, Du Geon; Kwak, Tae Il; Kim, Je Jong

    2015-08-01

    Glans penis augmentation (GPA) has received little attention from experts despite the existence of a subset of patients who may be dissatisfied with a small glans or poor tumescence of the glans during erection. Recently, GPA using an injectable filler or implantation of a graft or filler has been developed. Despite a demanding injection technique and inevitable uneven undulation of the glandular surface, GPA using injectable hyaluronic acid (HA) gel is a novel and useful therapy and an effective and safe procedure for soft tissue enhancement. For long-term presence of implants, timed supplementation can be used similar to that for fascial plasty. In complications such as mucosal necrosis of the glans penis, most cases occur from the use of non-HA gel or an unpurified form and misunderstanding of the management protocol for immediate side effects. Currently, GPA using injectable HA gel is not recommended in the International Society for Sexual Medicine guideline due to possible sensory loss. In a 5-year long-term follow-up of GPA by subcutaneous injection of HA gel, the residual volume of implants decreased by 15% of the maximal glandular circumference, but was still effective for alleviating the hypersensitivity of the glans penis in premature ejaculation patients. For efficacy in premature ejaculation, selection of appropriate candidates is the most important factor for success. GPA does not harm erectile function and is less invasive and irreversible compared to dorsal neurectomy. To refine the procedure, more interest and well-designed studies are required for the establishment of the procedure.

  9. Comparative Experiments to Assess the Effects of Accumulator Nitrogen Injection on Passive Core Cooling During Small Break LOCA

    Directory of Open Access Journals (Sweden)

    Li Yuquan

    2017-02-01

    Full Text Available The accumulator is a passive safety injection device for emergency core cooling systems. As an important safety feature for providing a high-speed injection flow to the core by compressed nitrogen gas pressure during a loss-of-coolant accident (LOCA, the accumulator injects its precharged nitrogen into the system after its coolant has been emptied. Attention has been drawn to the possible negative effects caused by such a nitrogen injection in passive safety nuclear power plants. Although some experimental work on the nitrogen injection has been done, there have been no comparative tests in which the effects on the system responses and the core safety have been clearly assessed. In this study, a new thermal hydraulic integral test facility—the advanced core-cooling mechanism experiment (ACME—was designed and constructed to support the CAP1400 safety review. The ACME test facility was used to study the nitrogen injection effects on the system responses to the small break loss-of-coolant accident LOCA (SBLOCA transient. Two comparison test groups—a 2-inch cold leg break and a double-ended direct-vessel-injection (DEDVI line break—were conducted. Each group consists of a nitrogen injection test and a nitrogen isolation comparison test with the same break conditions. To assess the nitrogen injection effects, the experimental data that are representative of the system responses and the core safety were compared and analyzed. The results of the comparison show that the effects of nitrogen injection on system responses and core safety are significantly different between the 2-inch and DEDVI breaks. The mechanisms of the different effects on the transient were also investigated. The amount of nitrogen injected, along with its heat absorption, was likewise evaluated in order to assess its effect on the system depressurization process. The results of the comparison and analyses in this study are important for recognizing and understanding the

  10. Comparative experiments to assess the effects of accumulator nitrogen injection on passive core cooling during small break LOCA

    Energy Technology Data Exchange (ETDEWEB)

    Li, YuQuan; Hao, Botao; Zhong, Jia; Wan Nam [State Nuclear Power Technology R and D Center, South Park, Beijing Future Science and Technology City, Beijing (China)

    2017-02-15

    The accumulator is a passive safety injection device for emergency core cooling systems. As an important safety feature for providing a high-speed injection flow to the core by compressed nitrogen gas pressure during a loss-of-coolant accident (LOCA), the accumulator injects its precharged nitrogen into the system after its coolant has been emptied. Attention has been drawn to the possible negative effects caused by such a nitrogen injection in passive safety nuclear power plants. Although some experimental work on the nitrogen injection has been done, there have been no comparative tests in which the effects on the system responses and the core safety have been clearly assessed. In this study, a new thermal hydraulic integral test facility—the advanced core-cooling mechanism experiment (ACME)—was designed and constructed to support the CAP1400 safety review. The ACME test facility was used to study the nitrogen injection effects on the system responses to the small break loss-of-coolant accident LOCA (SBLOCA) transient. Two comparison test groups—a 2-inch cold leg break and a double-ended direct-vessel-injection (DEDVI) line break—were conducted. Each group consists of a nitrogen injection test and a nitrogen isolation comparison test with the same break conditions. To assess the nitrogen injection effects, the experimental data that are representative of the system responses and the core safety were compared and analyzed. The results of the comparison show that the effects of nitrogen injection on system responses and core safety are significantly different between the 2-inch and DEDVI breaks. The mechanisms of the different effects on the transient were also investigated. The amount of nitrogen injected, along with its heat absorption, was likewise evaluated in order to assess its effect on the system depressurization process. The results of the comparison and analyses in this study are important for recognizing and understanding the potential negative

  11. Prevalence and correlates of neck injection among people who inject drugs in Tijuana, Mexico.

    Science.gov (United States)

    Rafful, Claudia; Wagner, Karla D; Werb, Dan; González-Zúñiga, Patricia E; Verdugo, Silvia; Rangel, Gudelia; Strathdee, Steffanie A

    2015-11-01

    Injecting drugs in the neck has been related to adverse health conditions such as jugular vein thrombosis, deep neck infections, aneurysm, haematomas, airway obstruction, vocal cord paralysis and wound botulism, among others. We identified prevalence and correlates of neck injection among people who inject drugs (PWID) in Tijuana, Mexico. Beginning in 2011, PWID aged ≥18 years who injected drugs within the last month were recruited into a prospective cohort. At baseline and semi-annually, PWID completed interviewer-administered surveys soliciting data on drug-injecting practices. Logistic regression was used to identify predictors of injecting in the neck as the most frequent injection site at a single visit. Of 380 PWID, 35.3% injected in the neck at least once in the past 6 months, among whom 71.6% reported it as their most common injection site, the most common injecting site after the arms (47%). Controlling for age, years injecting and injecting frequency, injecting heroin and methamphetamine two or more times per day and having sought injection assistance were associated with injecting in the neck [adjusted odds ratios (AOR): 2.12; 95% confidence intervals (CI): 1.27-3.53 and AOR: 2.65; 95% CI: 1.52-4.53 respectively]. Injecting in the neck was very common among PWID in Tijuana and was associated with polydrug use and seeking injection assistance. Tailoring harm reduction education interventions for individuals who provide injection assistance ('hit doctors') may allow for the dissemination of safe injecting knowledge to reduce injection-related morbidity and mortality. © 2015 Australasian Professional Society on Alcohol and other Drugs.

  12. Effects of mold geometry on fiber orientation of powder injection molded metal matrix composites

    Energy Technology Data Exchange (ETDEWEB)

    Ahmad, Faiz, E-mail: faizahmad@petronas.com.my; Aslam, Muhammad, E-mail: klaira73@gmail.com; Altaf, Khurram, E-mail: khurram.altaf@petronas.com.my; Shirazi, Irfan, E-mail: irfanshirazi@hotmail.com [Mechanical Engineering Universiti Teknologi PETRONAS Malaysia (Malaysia)

    2015-07-22

    Fiber orientations in metal matrix composites have significant effect on improving tensile properties. Control of fiber orientations in metal injection molded metal composites is a difficult task. In this study, two mold cavities of dimensions 6x6x90 mm and 10x20x180 mm were used for comparison of fiber orientation in injection molded metal composites test parts. In both mold cavities, convergent and divergent flows were developed by modifying the sprue dimensions. Scanning electron microscope (SEM) was used to examine the fiber orientations within the test samples. The results showed highly aligned fiber in injection molded test bars developed from the convergent melt flow. Random orientation of fibers was noted in the composites test bars produced from divergent melt flow.

  13. Small-Volume Injections: Evaluation of Volume Administration Deviation From Intended Injection Volumes.

    Science.gov (United States)

    Muffly, Matthew K; Chen, Michael I; Claure, Rebecca E; Drover, David R; Efron, Bradley; Fitch, William L; Hammer, Gregory B

    2017-10-01

    In the perioperative period, anesthesiologists and postanesthesia care unit (PACU) nurses routinely prepare and administer small-volume IV injections, yet the accuracy of delivered medication volumes in this setting has not been described. In this ex vivo study, we sought to characterize the degree to which small-volume injections (≤0.5 mL) deviated from the intended injection volumes among a group of pediatric anesthesiologists and pediatric postanesthesia care unit (PACU) nurses. We hypothesized that as the intended injection volumes decreased, the deviation from those intended injection volumes would increase. Ten attending pediatric anesthesiologists and 10 pediatric PACU nurses each performed a series of 10 injections into a simulated patient IV setup. Practitioners used separate 1-mL tuberculin syringes with removable 18-gauge needles (Becton-Dickinson & Company, Franklin Lakes, NJ) to aspirate 5 different volumes (0.025, 0.05, 0.1, 0.25, and 0.5 mL) of 0.25 mM Lucifer Yellow (LY) fluorescent dye constituted in saline (Sigma Aldrich, St. Louis, MO) from a rubber-stoppered vial. Each participant then injected the specified volume of LY fluorescent dye via a 3-way stopcock into IV tubing with free-flowing 0.9% sodium chloride (10 mL/min). The injected volume of LY fluorescent dye and 0.9% sodium chloride then drained into a collection vial for laboratory analysis. Microplate fluorescence wavelength detection (Infinite M1000; Tecan, Mannedorf, Switzerland) was used to measure the fluorescence of the collected fluid. Administered injection volumes were calculated based on the fluorescence of the collected fluid using a calibration curve of known LY volumes and associated fluorescence.To determine whether deviation of the administered volumes from the intended injection volumes increased at lower injection volumes, we compared the proportional injection volume error (loge [administered volume/intended volume]) for each of the 5 injection volumes using a linear

  14. Erythropoietin receptor in human skeletal muscle and the effects of acute and long-term injections with recombinant human erythropoietin on the skeletal muscle

    DEFF Research Database (Denmark)

    Lundby, Carsten; Hellsten, Ylva; Jensen, Mie B. F.

    2008-01-01

    The presence and potential physiological role of the erythropoietin receptor (Epo-R) were examined in human skeletal muscle. In this study we demonstrate that Epo-R is present in the endothelium, smooth muscle cells, and in fractions of the sarcolemma of skeletal muscle fibers. To study...... the potential effects of Epo in human skeletal muscle, two separate studies were conducted: one to study the acute effects of a single Epo injection on skeletal muscle gene expression and plasma hormones and another to study the effects of long-term (14 wk) Epo treatment on skeletal muscle structure. Subjects...... was studied in subjects (n = 8) who received long-term Epo administration, and muscle biopsies were obtained before and after. Epo treatment did not alter mean fiber area (0.84 +/- 0.2 vs. 0.72 +/- 0.3 mm(2)), capillaries per fiber (4.3 +/- 0.5 vs. 4.4 +/- 1.3), or number of proliferating endothelial cells...

  15. Injection and accumulation method in the TARN

    International Nuclear Information System (INIS)

    Yamada, S.; Katayama, T.

    1979-03-01

    The test accumulation ring for NUMATRON (TARN) is being constructed at INS, University of Tokyo. The main purpose of the TARN is to establish some techniques related to beam injection and RF stacking, ultrahigh vacuum, and beam monitoring and handling. In this paper, the injection and accumulation methods in the TARN are described. The combination of multiturn injection and RF stacking is applied to the TARN. Heavy ions from the INS sector focusing (SF) cyclotron are injection through a magnetic and an electrostatic inflectors. Two pulse magnets and a bump field excited by square wave current are used for the multiturn injection method. The procedure of the RF stacking is as follows. The beam from the cyclotron is transported to the ring, and is injected by a multiturn method. Then, the RF accelerating voltage is put on, and the beam is captured in the stable region of the RF acceleration. The RF voltage and the frequency are adiabatically changed, and the beam is moved to the stacking orbit. The RF voltage is put off, and the beam remains on the stacking orbit. In the present system, a repetitive stacking scheme is applied for the RF stacking. The momentum spread after the RF stacking is approximately proportional to the stacking number in synchrotron phase space. The stacking number is chosen so that the total aperture required for the combined method may not exceed the available aperture in the ring doughnut. (Kato, T.)

  16. Evaluation of the Non-Transient Hydrologic Source Term from the CAMBRIC Underground Nuclear Test in Frenchman Flat, Nevada Test Site

    International Nuclear Information System (INIS)

    Tompson, A B; Maxwell, R M; Carle, S F; Zavarin, M; Pawloski, G A.; Shumaker, D E

    2005-01-01

    Hydrologic Source Term (HST) calculations completed in 1998 at the CAMBRIC underground nuclear test site were LLNL's first attempt to simulate a hydrologic source term at the NTS by linking groundwater flow and transport modeling with geochemical modeling (Tompson et al., 1999). Significant effort was applied to develop a framework that modeled in detail the flow regime and captured all appropriate chemical processes that occurred over time. However, portions of the calculations were simplified because of data limitations and a perceived need for generalization of the results. For example: (1) Transient effects arising from a 16 years of pumping at the site for a radionuclide migration study were not incorporated. (2) Radionuclide fluxes across the water table, as derived from infiltration from a ditch to which pumping effluent was discharged, were not addressed. (3) Hydrothermal effects arising from residual heat of the test were not considered. (4) Background data on the ambient groundwater flow direction were uncertain and not represented. (5) Unclassified information on the Radiologic Source Term (RST) inventory, as tabulated recently by Bowen et al. (2001), was unavailable; instead, only a limited set of derived data were available (see Tompson et al., 1999). (6) Only a small number of radionuclides and geochemical reactions were incorporated in the work. (7) Data and interpretation of the RNM-2S multiple well aquifer test (MWAT) were not available. As a result, the current Transient CAMBRIC Hydrologic Source Term project was initiated as part of a broader Phase 2 Frenchman Flat CAU flow and transport modeling effort. The source term will be calculated under two scenarios: (1) A more specific representation of the transient flow and radionuclide release behavior at the site, reflecting the influence of the background hydraulic gradient, residual test heat, pumping experiment, and ditch recharge, and taking into account improved data sources and modeling

  17. On-ground testing of the role of adhesion in the LISA-Pathfinder test mass injection phase

    Science.gov (United States)

    Bortoluzzi, D.; Zanoni, C.; Conklin, J. W.

    2017-05-01

    Many space missions share the need to fly a free-falling body inside the spacecraft, as a reference for navigation and/or as a probe for the local gravitational field. When a mechanism is required to cage such an object during the launch phase, the need arises to release it to free-fall once the operational phase must be initiated in orbit. The criticality of this phase increases when the mechanical interfaces between the body and the mechanism are affected by adhesion and the actuation authority of the control system on the free-falling body is limited. Both conditions are realized in the LISA Pathfinder mission, which aims at injecting a gold-coated 2 kg cubic test mass into a nearly perfect geodesic trajectory to demonstrate the readiness of the developed technology for in-space gravity wave detection. The criticality of adhesion is widely recognized in space technology, because it can affect and jeopardize the functionality of mechanisms, when arising between moving parts. In the LISA Pathfinder case, metallic adhesion potentially plays a relevant role, mainly for two reasons. First, thanks to its properties (ductility, high surface energy) the gold coating on the proof mass easily produces cold weldings, especially in vacuum conditions. Second, the detachment of the proof mass from the releasing device occurs abruptly and a relevant influence of the separation velocity is expected on the strength of the welding. This can produce an excessive velocity of the proof mass at the retraction of the releasing device for the following capture and centring phase on behalf of the control system. A testing activity is performed to characterize the dynamic behaviour of the adhesive bonds between the proof mass and the releasing device, which can be used to predict their contribution on the residual velocity of the proof mass after in-flight release. The study of such a dynamic phenomenon sets some challenging requirements on the measurement technique, both on the

  18. Tennis elbow: role of local steroid injection.

    Science.gov (United States)

    Ahmed, Gulzar Saeed; Ali, Muhammad; Trago, Imtiaz Ahmed

    2012-01-01

    Tennis elbow is a condition, characterised by pain and tenderness over the lateral epicondyle of the humerus, and pain on resisted dorsiflexion of the wrist, middle finger, or both. The aim of this randomised controlled trial was to investigate the short term efficacy of local steroid injection compared with oral and topical NSAIDs. Sixty patients (45 male and 15 female) were included in the study. The mean age was 42 years for men and 40 years for women. They were placed in group A and B (30 cases each). Group A received local steroid injection (triamcinolone 20 mg mixed with lignocaine 2% 1 cc) and topical NSAID cream application (diclofenac diethylammonium) twice a day, tab. diclofenac sodium 50 mg twice a day for 3 weeks. Group B received tab diclofenac 50 mg twice a day and, topical NSAID cream application twice a day for 3 weeks. Assessment of patients was made 3 times; first at the start of the study, 2nd time after 6 weeks, and 3rd time after 12 weeks. A blinded assessor rated the elbow complaints of the patients at resisted dorsiflexion of wrist using VAS (0 = no severity, 1-3 mild, 4-6 moderate, 7-9 sever, 10 = maximum severity). At six weeks, 22 (73.33%) patient in group A had no pain as compared to 7 (23.33%) patients in group B who were pain free (p < 0.0001, chi2 = 38.75). At 12 weeks 27 (90%) patients in group A were pain free compared to group B in which 7 (23.33%) patients were pain free (p < 0.0001, chi2 = 27.56). In patients with tennis elbow, the use of local steroid injection in combination with topical and oral NSAIDs is superior to the use of combination of topical and oral NSAIDs. Better results with combination therapy using local steroid injection may be limited to the short term.

  19. Design and development of a direct injection system for cryogenic engines

    Science.gov (United States)

    Mutumba, Angela; Cheeseman, Kevin; Clarke, Henry; Wen, Dongsheng

    2018-04-01

    The cryogenic engine has received increasing attention due to its promising potential as a zero-emission engine. In this study, a new robust liquid nitrogen injection system was commissioned and set up to perform high-pressure injections into an open vessel. The system is used for quasi-steady flow tests used for the characterisation of the direct injection process for cryogenic engines. An electro-hydraulic valve actuator provides intricate control of the valve lift, with a minimum cycle time of 3 ms and a frequency of up to 20 Hz. With additional sub-cooling, liquid phase injections from 14 to 94 bar were achieved. Results showed an increase in the injected mass with the increase in pressure, and decrease in temperature. The injected mass was also observed to increases linearly with the valve lift. Better control of the injection process, minimises the number of variables, providing more comparable and repeatable sets of data. Implications of the results on the engine performance were also discussed.

  20. SQL Injection Defenses

    CERN Document Server

    Nystrom, Martin

    2007-01-01

    This Short Cut introduces you to how SQL injection vulnerabilities work, what makes applications vulnerable, and how to protect them. It helps you find your vulnerabilities with analysis and testing tools and describes simple approaches for fixing them in the most popular web-programming languages. This Short Cut also helps you protect your live applications by describing how to monitor for and block attacks before your data is stolen. Hacking is an increasingly criminal enterprise, and web applications are an attractive path to identity theft. If the applications you build, manage, or guar

  1. Seismicity rate surge on faults after shut-in: poroelastic response to fluid injection

    Science.gov (United States)

    Chang, K. W.; Yoon, H.; Martinez, M. J.

    2017-12-01

    Subsurface energy activities such as geological CO2 storage and wastewater injection require injecting large amounts of fluid into the subsurface, which will alter the states of pore pressure and stress in the storage formation. One of the main issues for injection-induced seismicity is the post shut-in increases in the seismicity rate, often observed in the fluid-injection operation sites. The rate surge can be driven by the following mechanisms: (1) pore-pressure propagation into distant faults after shut-in and (2) poroelastic stressing caused by well operations, depending on fault geometry, hydraulic and mechanical properties of the formation, and injection history. We simulate the aerial view of the target reservoir intersected by strike-slip faults, in which injection-induced pressure buildup encounters the faults directly. We examine the poroelastic response of the faults to fluid injection and perform a series of sensitivity tests considering: (1) permeability of the fault zone, (2) locations and the number of faults with respect to the injection point, and (3) well operations with varying the injection rate. Our analysis of the Coulomb stress change suggests that the sealing fault confines pressure diffusion which stabilizes or weakens the nearby conductive fault depending on the injection location. We perform the sensitivity test by changing injection scenarios (time-dependent rates), while keeping the total amount of injected fluids. Sensitivity analysis shows that gradual reduction of the injection rate minimizes the Coulomb stress change and the least seismicity rates are predicted. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology and Engineering Solutions of Sandia, LLC., a wholly owned subsidiary of Honeywell International, Inc., for the U.S. Department of Energy's National Nuclear Security Administration under contract DE-NA-0003525.

  2. Local corticosteroid versus autologous blood injections in lateral epicondylitis: meta-analysis of randomized controlled trials.

    Science.gov (United States)

    Sirico, Felice; Ricca, Flavia; DI Meglio, Franca; Nurzynska, Daria; Castaldo, Clotilde; Spera, Rocco; Montagnani, Stefania

    2017-06-01

    Lateral epicondylitis is a common painful elbow disorder. Several approaches to treatment have been proposed, with a local injection of corticosteroids being the most frequently used. Recent insights into the pathophysiology encouraged the introduction of autologous blood injections as an alternative treatment method. The aim of this meta-analysis is to summarize quantitatively the evidence regarding the efficacy of corticosteroids and autologous blood injections for treatment of pain in lateral epicondylitis. Studies were considered eligible based on the following inclusion criteria: adult human, diagnosis of lateral epicondylitis, randomized controlled trials comparing corticosteroids versus autologous blood injections, pain assessment. Exclusion criteria were previous surgery for lateral epicondylitis or for other elbow disorders, concurrent treatment with drugs or physiotherapy, diagnosis of musculoskeletal systemic disorder. A systematic search of literature was performed according to the PRISMA statement. Effect size of each included study was calculated and analyzed in a random-effects model. Four studies, enrolling total of 218 patients (139 females and 79 males), were included in quantitative analysis. At 2 weeks, there was a trend towards a reduction of VAS score in the corticosteroid group (WMD=2.12 [95% CI: 4.38 to 0.14], P=0.07). No significant differences were recorded in the medium-term (4-12 weeks; WMD=0.85 [95% CI: -0.44 to 2.15], P=0.19) and long-term (24 weeks; WMD=0.63 [95% CI: -2.40 to 3.66], P=0.68) follow-up. Few high-quality trials compare the efficacy of corticosteroid and autologous blood injections in the control of pain related to lateral epicondylitis. Available data indicate that corticosteroids tend to reduce VAS score in short-term follow-up, although these data are not statistically significant. No differences were recorded in the medium and long term. Contrary to popular opinion among medical professionals, and despite

  3. Short- and long-term antidepressant effects of ketamine in a rat chronic unpredictable stress model.

    Science.gov (United States)

    Jiang, Yinghong; Wang, Yiqiang; Sun, Xiaoran; Lian, Bo; Sun, Hongwei; Wang, Gang; Du, Zhongde; Li, Qi; Sun, Lin

    2017-08-01

    This research was aimed to evaluate the behaviors of short- or long-term antidepressant effects of ketamine in rats exposed to chronic unpredictable stress (CUS). Ketamine, a glutamate noncompetitive NMDA receptor antagonist, regulates excitatory amino acid functions, such as anxiety disorders and major depression, and plays an important role in synaptic plasticity and learning and memory. After 42 days of CUS model, male rats received either a single injection of ketamine (10 mg/kg; day 43) or 15 daily injections (days 43-75). The influence of ketamine on behavioral reactivity was assessed 24 hr (short-term) or 7 weeks after ketamine treatment (long-term). Behavioral tests used to assess the effects of these treatments included the sucrose preference (SP), open field (OF), elevated plus maze (EPM), forced swimming (FS), and water maze (WM) to detect anxiety-like behavior (OF and EPM), forced swimming (FS), and water maze (WM). Results: Short-term ketamine administration resulted in increases of body weight gain, higher sensitivity to sucrose, augmented locomotor activity in the OF, more entries into the open arms of the EPM, along increased activity in the FS test; all responses indicative of reductions in depression/despair in anxiety-eliciting situations. No significant differences in these behaviors were obtained under conditions of long-term ketamine administration ( p  > .05). The CUS + Ketamine group showed significantly increased activity as compared with the CUS + Vehicle group for analysis of the long-term effects of ketamine (* p   .05). Taken together these findings demonstrate that a short-term administration of ketamine induced rapid antidepressant-like effects in adult male rats exposed to CUS conditions, effects that were not observed in response to the long-term treatment regime.

  4. Extension of Surveillance Test Interval of Safety Injection Pump for APR-1400 Reactors to Improve Reliability and Availability of the Pump

    Energy Technology Data Exchange (ETDEWEB)

    Osama, A. Rezk; Jung, J. C.; Lee, Yong-Kwan [KEPCO International Nuclear Graduate School, Ulsan (Korea, Republic of)

    2015-10-15

    The safety features function to localize, control, mitigate, and terminate such incidents and to hold exposure levels below applicable limits. The safety injection system is comprised of four independent mechanical trains without any tie line among the injection paths and two electrical divisions. Each train has one active Safety Injection Pump (SIP) and one passive Safety Injection Tank (SIT) equipped with a Fluidic Device (FD), each train provides 50% of the minimum injection flow rate for breaks larger than the size of a direct vessel injection line. For breaks equal to or smaller than the size of a direct vessel injection line, each train has 100% of the required capacity. The low pressure injection pumps with common header installed in the conventional design are eliminated, and the functions for safety injection and shutdown cooling are separated. The arrangement of safety injection system for APR-1400 as shown in figure (1). The results obtained in this work show that STI extensions for the SIS feasible without any unacceptable increase in the plant total risk, STI extensions are acceptable for safety injection system to provide plant operational flexibility in the performance of both corrective and preventive maintenance for the safety injection system.

  5. Colistimethate Injection

    Science.gov (United States)

    ... injection is in a class of medications called antibiotics. It works by killing bacteria.Antibiotics such as colistimethate injection will not work for colds, flu, or other viral infections. Using ...

  6. INTRAARTICULAR INJECTION OF HYALURONIC ACID AFTER ARTHROSCOPIC LAVAGE OF THE KNEE: LONG-TERM RESULTS

    Directory of Open Access Journals (Sweden)

    Lidia Vladimirovna Luchikhina

    2013-01-01

    Full Text Available Objective: to evaluate the efficiency of arthroscopic lavage in combination with subsequent injection of hyaluronic acid into the joint cavity at shortand long-term follow-ups. Subjects and methods. Eighty-two patients with knee osteoarthrosis (OA were examined in accordance with the American College of Rheumatology criteria. Group 1 consisted of 40 patients only after arthroscopic lavage; Group 2 comprised 42 patients who were administered hyaluronic acid after arthroscopic lavage. Clinical evaluation encompassed pain while walking, resting, and moving (by a visual analogue scale, limited ability in covering 100 m (by a 5-point scale, general clinical evaluation (by a 5-point ordinal scale, the presence or absence of pain after 100-m walking, as well as resting pain (its presence or absence. Results. The treatment effect evaluated using different indicators was comparably positive in both groups within 3 months. Following 3 months of therapy, its effect remained stable and even better in Group 2. The latter showed a particularly noticeable superiority a year later. Thus, there were excellent and good results in 88 and 47.5% in Groups 2 and 1, respectively. The clinical symptoms of the disease were absent in 58% in Group 2 and in only 15% in Group 1. Moreover, Group 1 showed worsening and 20% of the patients had no effect. This trend was also seen while evaluating the therapeutic effectiveness in different periods. Thus, after therapy, no substantial difference was found in both groups, but 3 months later this difference was as many as 0.8 scores and a year later Group 2 had many points in its favor (1.2 scores. Conclusion. Arthroscopic lavage followed by the administration of hyaluronic acid makes it possible to prevent the negative effect of a washing liquid on the metabolism and structure of the articular cartilage and to achieve a long-term effect against the major clinical symptoms (joint pain and function affecting the quality of life. The

  7. Injectable TEMPO-oxidized nanofibrillated cellulose/biphasic calcium phosphate hydrogel for bone regeneration.

    Science.gov (United States)

    Safwat, Engie; Hassan, Mohammad L; Saniour, Sayed; Zaki, Dalia Yehia; Eldeftar, Mervat; Saba, Dalia; Zazou, Mohamed

    2018-05-01

    Nanofibrillated cellulose, obtained from rice straw agricultural wastes was used as a substrate for the preparation of a new injectable and mineralized hydrogel for bone regeneration. Tetramethyl pyridine oxyl (TEMPO) oxidized nanofibrillated cellulose, was mineralized through the incorporation of a prepared and characterized biphasic calcium phosphate at a fixed ratio of 50 wt%. The TEMPO-oxidized rice straw nanofibrillated cellulose was characterized using transmission electron microscopy, Fourier transform infrared, and carboxylic content determination. The injectability and viscosity of the prepared hydrogel were evaluated using universal testing machine and rheometer testing, respectively. Cytotoxicity and alkaline phosphatase level tests on osteoblast like-cells for in vitro assessment of the biocompatibility were investigated. Results revealed that the isolated rice straw nanofibrillated cellulose is a nanocomposite of the cellulose nanofibers and silica nanoparticles. Rheological properties of the tested materials are suitable for use as injectable material and of nontoxic effect on osteoblast-like cells, as revealed by the positive alkaline phosphate assay. However, nanofibrillated cellulose/ biphasic calcium phosphate hydrogel showed higher cytotoxicity and lower bioactivity test results when compared to that of nanofibrillated cellulose.

  8. Injection molded self-cleaning surfaces

    DEFF Research Database (Denmark)

    Søgaard, Emil

    that are superhydrophobic based on topography rather than chemical compounds. Therefore, a novel method for fabricating superhydrophobic polymer surfaces with excellent water-repellant properties is developed. The method is based on microstructure fabrication and superposed nanostructures on silicon wafers. The nano......- and microstructured silicon is electroplated with nickel and the resulting nickel shim with inverse polarity is used in an injection molding process. A versatile injection molding process capable of producing different nano- and microstructures on areas larger than 10 cm2 is developed. Variotherm mold heating is used...... hierarchical structures with nanograss and holes. Water wetting tests are carried out using a pressure cell to control the water pressure. Microscopic wetting behavior of the structures is studied by optical transmission microscopy. Interestingly, it is found that the surface chemistry of the polymer changes...

  9. Glenohumeral Joint Injections

    Science.gov (United States)

    Gross, Christopher; Dhawan, Aman; Harwood, Daniel; Gochanour, Eric; Romeo, Anthony

    2013-01-01

    Context: Intra-articular injections into the glenohumeral joint are commonly performed by musculoskeletal providers, including orthopaedic surgeons, family medicine physicians, rheumatologists, and physician assistants. Despite their frequent use, there is little guidance for injectable treatments to the glenohumeral joint for conditions such as osteoarthritis, adhesive capsulitis, and rheumatoid arthritis. Evidence Acquisition: We performed a comprehensive review of the available literature on glenohumeral injections to help clarify the current evidence-based practice and identify deficits in our understanding. We searched MEDLINE (1948 to December 2011 [week 1]) and EMBASE (1980 to 2011 [week 49]) using various permutations of intra-articular injections AND (corticosteroid OR hyaluronic acid) and (adhesive capsulitis OR arthritis). Results: We identified 1 and 7 studies that investigated intra-articular corticosteroid injections for the treatment of osteoarthritis and adhesive capsulitis, respectively. Two and 3 studies investigated the use of hyaluronic acid in osteoarthritis and adhesive capsulitis, respectively. One study compared corticosteroids and hyaluronic acid injections in the treatment of osteoarthritis, and another discussed adhesive capsulitis. Conclusion: Based on existing studies and their level of evidence, there is only expert opinion to guide corticosteroid injection for osteoarthritis as well as hyaluronic acid injection for osteoarthritis and adhesive capsulitis. PMID:24427384

  10. DEPLETED HYDROCARBON RESERVOIRS AND CO2 INJECTION WELLS –CO2 LEAKAGE ASSESSMENT

    Directory of Open Access Journals (Sweden)

    Nediljka Gaurina-Međimurec

    2017-03-01

    Full Text Available Migration risk assessment of the injected CO2 is one of the fi rst and indispensable steps in determining locations for the implementation of projects for carbon dioxide permanent disposal in depleted hydrocarbon reservoirs. Within the phase of potential storage characterization and assessment, it is necessary to conduct a quantitative risk assessment, based on dynamic reservoir models that predict the behaviour of the injected CO2, which requires good knowledge of the reservoir conditions. A preliminary risk assessment proposed in this paper can be used to identify risks of CO2 leakage from the injection zone and through wells by quantifying hazard probability (likelihood and severity, in order to establish a risk-mitigation plan and to engage prevention programs. Here, the proposed risk assessment for the injection well is based on a quantitative risk matrix. The proposed assessment for the injection zone is based on methodology used to determine a reservoir probability in exploration and development of oil and gas (Probability of Success, abbr. POS, and modifi ed by taking into account hazards that may lead to CO2 leakage through the cap rock in the atmosphere or groundwater. Such an assessment can eliminate locations that do not meet the basic criteria in regard to short-term and long-term safety and the integrity of the site

  11. Microwave coagulation therapy and drug injection to treat splenic injury.

    Science.gov (United States)

    Zhang, Guoming; Sun, Yuanyuan; Yu, Jie; Dong, Lei; Mu, Nannan; Liu, Xiaohong; Liu, Lanfen; Zhang, Yan; Wang, Xiaofei; Liang, Ping

    2014-01-01

    The present study compares the efficacy of 915- and 2450-MHz contrast-enhanced ultrasound (CEUS)-guided percutaneous microwave coagulation with that of CEUS-guided thrombin injection for the treatment of trauma-induced spleen hemorrhage. In a canine splenic artery hemorrhage model with two levels of arterial diameter (A, microwaves and drug injection. Therapy efficacy was measured by comparing bleeding rate, hemostatic time, bleeding index, bleeding volume, and pathology. The most efficient technique was CEUS-guided 915-MHz percutaneous microwave coagulation therapy in terms of action time and total blood loss. The success rate of the 915-MHz microwave group was higher than that of the 2450-MHz microwave and the drug injection groups (except A level, P microwave group than those in the 2450-MHz microwave and drug injection groups (P microwave group, but pathologic changes of light injury could be seen in the other groups. The present study provides evidence that microwave coagulation therapy is more efficient than thrombin injection for the treatment of splenic hemorrhage. Furthermore, treatment with 915-MHz microwaves stops bleeding more rapidly and generates a wider cauterization zone than does treatment with 2450-MHz microwaves. Copyright © 2014 Elsevier Inc. All rights reserved.

  12. CFD analysis of poison injection in AHWR calandria

    International Nuclear Information System (INIS)

    Kansal, A.K.; Kamble, M.T.; Maheshwari, N.K.; Vijayan, P.K.

    2014-01-01

    The present work intends to give details of design and performance validation of SDS-2. The performance is evaluated on the basis of dispersion of poison in calandria in a given period of time. Location of injection tube and injection holes, size of jet hole and number of holes are some of the design parameters which greatly affect dispersion of poison in calandria. A Computational Fluid Dynamic (CFD) study for axial and radial injection of poison was carried out using open source CFD code OpenFOAM. CFD benchmarking was done using experiments performed by Johari (Johari et al. 1997) to identify suitable turbulence model for this problem. An experimental facility simulating poison injection in moderator in presence of calandria tubes was used to further validate the CFD model is shown in the paper. CFD analysis was carried out for axial as well as radial injection for AHWR geometry. CFD analysis using OpenFOAM has been carried out to study high pressure poison injection for single jet of Shut Down System - 2 (SDS- 2) of Advanced Heavy Water Reactor (AHWR) for various design options. CFD model used in analysis have been validated with experimental data available in literature as well as experiments performed for AHWR specific geometry. Various turbulence models are tested and their adequacy for such flow problems has been established. The CFD model is then used to simulate poison injection for two design options for AHWR and their performance is compared. (author)

  13. Systematic assessment of microneedle injection into the mouse cornea.

    Science.gov (United States)

    Matthaei, Mario; Meng, Huan; Bhutto, Imran; Xu, Qingguo; Boelke, Edwin; Hanes, Justin; Jun, Albert S

    2012-06-20

    Corneal intrastromal injection is an important mode of gene-vector application to subepithelial layers. In a mouse model, this procedure is substantially complicated by the reduced corneal dimensions. Furthermore, it may be difficult to estimate the corneal area reached by the volume of a single injection. This study aimed to investigate intrastromal injections into the mouse cornea using different microneedles and to quantify the effect of injecting varying volumes. A reproducible injection technique is described. Forty eyes of 20 129 Sv/J mice were tested. India ink was intrastromally injected using 30° beveled 33 G needles, tri-surface 25° beveled 35 G needles, or hand-pulled and 25° beveled glass needles. Each eye received a single injection of a volume of 1 or 2 μL. Corneoscleral buttons were fixed and flat mounted for computer-assisted quantification of the affected corneal area. Histological assessment was performed to investigate the intrastromal location of the injected dye. A mean corneal area of 5.0 ± 1.4 mm(2) (mean ± SD) and 7.7 ± 1.4 mm(2) was covered by intrastromal injections of 1 and 2 μL, respectively. The mean percentage of total corneal area reached ranged from 39% to 53% for 1 μL injections, and from 65% to 81% for 2 μL injections. Injections using the 33 G needles tended to provide the highest distribution area. Perforation rates were 8% for 30° beveled 33 G needles and 44% for tri-surface beveled 35 G needles. No perforation was observed with glass needle; however, intrastromal breakage of needle tips was noted in 25% of these cases. Intracorneal injection using a 30° beveled 33 G needle was safe and effective. The use of tri-surface beveled 35 G needles substantially increased the number of corneal perforations. Glass needles may break inside the corneal stroma. Injections of 1 μL and 2 μL resulted in an overall mean of 49% and 73% respectively of total corneal area involved.

  14. Can repeat injection provide clinical benefit in patients with cervical disc herniation and stenosis when the first epidural injection results only in partial response?

    Science.gov (United States)

    Lee, Jung Hwan; Lee, Sang-Ho

    2016-07-01

    Epidural steroid injection (ESI) is known to be an effective treatment for neck or radicular pain due to herniated intervertebral disc (HIVD) and spinal stenosis (SS). Although repeat ESI has generally been indicated to provide more pain relief in partial responders after single ESI, there has been little evidence supporting the usefulness of this procedure. The purpose of this study, therefore, was to determine whether repeat ESI at a prescribed interval of 2 to 3 weeks after the first injection would provide greater clinical benefit in patients with partial pain reduction than intermittent ESI performed only when pain was aggravated. One hundred eighty-four patients who underwent transforaminal ESI (TFESI) for treatment of axial neck and radicular arm pain due to HIVD or SS and could be followed up for 1 year were enrolled. We divided the patients into 2 groups. Group A (N = 108) comprised partial responders (numeric rating scale (NRS) ≥ 3 after the first injection) who underwent repeat injection at a prescribed interval of 2 to 3 weeks after the first injection. Group B (N = 76) comprised partial responders who did not receive repeat injection at the prescribed interval, but received intermittent injections only for aggravation of pain. Various clinical data were assessed, including total number of injections during 1 year, NRS duration of Group A, or after first injection in Group B (time to reinjection). Groups A and B were compared in terms of total population, HIVD, and SS. In the whole population, HIVD subgroup, and SS subgroup, patients in Group A required significantly fewer injections to obtain satisfactory pain relief during the 1-year follow-up period. Group A showed a significantly longer time to reinjection and longer NRS Group B did. Repeat TFESI conducted at 2- to 3-week intervals after the first injection in partial responders contributed to greater clinical benefit compared with intermittent TFESI performed only upon pain

  15. Error response test system and method using test mask variable

    Science.gov (United States)

    Gender, Thomas K. (Inventor)

    2006-01-01

    An error response test system and method with increased functionality and improved performance is provided. The error response test system provides the ability to inject errors into the application under test to test the error response of the application under test in an automated and efficient manner. The error response system injects errors into the application through a test mask variable. The test mask variable is added to the application under test. During normal operation, the test mask variable is set to allow the application under test to operate normally. During testing, the error response test system can change the test mask variable to introduce an error into the application under test. The error response system can then monitor the application under test to determine whether the application has the correct response to the error.

  16. The LEP injection monitors: Design and first results with beam

    International Nuclear Information System (INIS)

    Burtin, G.; Colchester, R.; Fischer, C.; Halvarsson, B.; Hemery, J.Y.; Jung, R.; Levitt, S.; Vouillot, J.M.

    1989-01-01

    The LEP injection monitors comprise of split foil monitors, luminescent screens and beam stoppers. The monitors are described with particular emphasis on their special features. These include: their low loss factors, their protection against synchrotron radiation and the screen read-out with a CCD chip. The results obtained during the positron injection tests in LEP in July 1988 are reported. 8 figs

  17. Enhancing the use of coals by gas reburning-sorbent injection: Volume 4 -- Gas reburning-sorbent injection at Lakeside Unit 7, City Water, Light and Power, Springfield, Illinois. Final report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-03-01

    A demonstration of Gas Reburning-Sorbent Injection (GR-SI) has been completed at a cyclone-fired utility boiler. The Energy and Environmental Research Corporation (EER) has designed, retrofitted and tested a GR-SI system at City Water Light and Power`s 33 MWe Lakeside Station Unit 7. The program goals of 60% NO{sub x} emissions reduction and 50% SO{sub 2} emissions reduction were exceeded over the long-term testing period; the NO{sub x} reduction averaged 63% and the SO{sub 2} reduction averaged 58%. These were achieved with an average gas heat input of 22% and a calcium (sorbent) to sulfur (coal) molar ratio of 1.8. GR-SI resulted in a reduction in thermal efficiency of approximately 1% at full load due to firing natural gas which forms more moisture in flue gas than coal and also results in a slight increase in air heater exit gas temperature. Minor impacts on other areas of unit performance were measured and are detailed in this report. The project at Lakeside was carried out in three phases, in which EER designed the GR-SI system (Phase 1), completed construction and start-up activities (Phase 2), and evaluated its performance with both short parametric tests and a long-term demonstration (Phase 3). This report contains design and technical performance data; the economics data for all sites are presented in Volume 5.

  18. Experimental and Numerical Investigations of Surge Extension on a Centrifugal Compressor with Vaned Diffuser Using Steam Injection

    Directory of Open Access Journals (Sweden)

    Chuang Gao

    2017-01-01

    Full Text Available This paper presents the first report on surge extension with steam injection through both experimental and numerical simulation. The experimental section covers the test facility, instrumentation, and prestall modes comparison with and without steam injection. It is found that surge extension is not in proportion to injected steam. There exists an upper bound above which deteriorates the margin. Injection of less than 1% of the designed mass flow can bring about over 10% margin improvement. Test results also indicated that steam injection not only damps out prestall waves, but also changes prestall modes and traveling direction. At 90% speed, injection changed the prestall mode from spike to modal, while at 80% speed line, it made the forward traveling wave become backward. Through numerical simulation, location and number of injectors, molecular weight, and temperature of injected gas are modified to explore their influences on surge margin. Similar to the test results, there exists an upper bound for the amount of steam injected. The flow field investigation indicates that this bound is caused by the early trigger of flow collapse due to the injected steam which is similar to the tip leakage flow spillage caused spike stall in axial compressors.

  19. Nonlinear dynamic behaviors of an optically injected vertical-cavity surface-emitting laser

    International Nuclear Information System (INIS)

    Li Xiaofeng; Pan Wei; Luo Bin; Ma Dong; Wang Yong; Li Nuohan

    2006-01-01

    Nonlinear dynamics of a vertical-cavity surface-emitting laser (VCSEL) with external optical injection are studied numerically. We consider a master-slave configuration where the dynamic characteristics of the slave are affected by the optical injection from the master, and we also establish the corresponding Simulink model. The period-doubling route as well as the period-halving route is observed, where the regular, double-periodic, and chaotic pulsings are found. By adjusting the injection strength properly, the laser can be controlled to work at a given state. The effects of frequency detuning on the nonlinear behaviors are also investigated in terms of the bifurcation diagrams of photon density with the frequency detuning. For weak injection case, the nonlinear dynamics shown by the laser are quite different when the value of frequency detuning varies contrarily (positive and negative direction). If the optical injection is strong enough, the slave can be locked by the master even though the frequency detuning is relatively large

  20. Repeated tender point injections of granisetron alleviate chronic myofascial pain--a randomized, controlled, double-blinded trial.

    Science.gov (United States)

    Christidis, Nikolaos; Omrani, Shahin; Fredriksson, Lars; Gjelset, Mattias; Louca, Sofia; Hedenberg-Magnusson, Britt; Ernberg, Malin

    2015-01-01

    Serotonin (5-HT) mediates pain by peripheral 5-HT3-receptors. Results from a few studies indicate that intramuscular injections of 5-HT3-antagonists may reduce musculoskeletal pain. The aim of this study was to investigate if repeated intramuscular tender-point injections of the 5-HT3-antagonist granisetron alleviate pain in patients with myofascial temporomandibular disorders (M-TMD). This prospective, randomized, controlled, double blind, parallel-arm trial (RCT) was carried out during at two centers in Stockholm, Sweden. The randomization was performed by a researcher who did not participate in data collection with an internet-based application ( www.randomization.com ). 40 patients with a diagnose of M-TMD according to the Research Diagnostic Criteria for Temporomandibular Disorders (RDC/TMD) were randomized to receive repeated injections, one week apart, with either granisetron (GRA; 3 mg) or isotonic saline as control (CTR). The median weekly pain intensities decreased significantly at all follow-ups (1-, 2-, 6-months) in the GRA-group (Friedman test; P  0.075). The numbers needed to treat (NNT) were 4 at the 1- and 6-month follow-ups, and 3.3 at the 2-month follow-up in favor of granisetron. Repeated intramuscular tender-point injections with granisetron provide a new pharmacological treatment possibility for myofascial pain patients with repeated intramuscular tender-point injections with the serotonin type 3 antagonist granisetron. It showed a clinically relevant pain reducing effect in the temporomandibular region, both in a short- and long-term aspect. European Clinical Trials Database 2005-006042-41 as well as at Clinical Trials NCT02230371 .

  1. Meropenem Injection

    Science.gov (United States)

    ... injection is in a class of medications called antibiotics. It works by killing bacteria that cause infection.Antibiotics such as meropenem injection will not work for colds, flu, or other viral infections. Taking ...

  2. Chloramphenicol Injection

    Science.gov (United States)

    ... injection is in a class of medications called antibiotics. It works by stopping the growth of bacteria..Antibiotics such as chloramphenicol injection will not work for colds, flu, or other viral infections. Taking ...

  3. The effectiveness of injections of hyaluronic acid or corticosteroid in patients with subacromial impingement: a three-arm randomised controlled trial.

    Science.gov (United States)

    Penning, L I F; de Bie, R A; Walenkamp, G H I M

    2012-09-01

    A total of 159 patients (84 women and 75 men, mean age of 53 (20 to 87)) with subacromial impingement were randomised to treatment with subacromial injections using lidocaine with one of hyaluronic acid (51 patients), corticosteroid (53 patients) or placebo (55 patients). Patients were followed up for 26 weeks. The primary outcome was pain on a visual analogue score (VAS), and secondary outcomes included the Constant Murley score, shoulder pain score, functional mobility score, shoulder disability questionnaire and pain-specific disability score. The different outcome measures showed similar results. After three, six and 12 weeks corticosteroid injections were superior to hyaluronic acid injections and only at six weeks significantly better than placebo injections. The mean short-term reduction in pain on the VAS score at 12 weeks was 7% (SD 2.7; 97.5% confidence interval (CI) 0.207 to 1.55; p = 0.084) in the hyaluronic acid group, 28% (SD 2.8; 97.5% CI 1.86 to 3.65; p hyaluronic acid group, 72% (38 of 53) of those in the corticosteroid group and 69% (38 of 55) of those in the placebo group. We were not able to show a convincing benefit from hyaluronic acid injections compared with corticosteroid or placebo injections. Corticosteroid injections produced a significant reduction in pain in the short term (three to 12 weeks), but in the long term the placebo injection produced the best results.

  4. Worldwide Injection Technique Questionnaire Study: Population Parameters and Injection Practices.

    Science.gov (United States)

    Frid, Anders H; Hirsch, Laurence J; Menchior, Astrid R; Morel, Didier R; Strauss, Kenneth W

    2016-09-01

    From February 1, 2014, through June 30, 2015, 13,289 insulin-injecting patients from 423 centers in 42 countries took part in one of the largest surveys ever performed in diabetes. The goal was to assess patient characteristics, as well as historical and practical aspects of their injection technique. Results show that 4- and 8-mm needle lengths are each used by nearly 30% of patients and 5- and 6-mm needles each by approximately 20%. Higher consumption of insulin (as measured by total daily dose) is associated with having lipohypertrophy (LH), injecting into LH, leakage from the injection site, and failing to reconstitute cloudy insulin. Glycated hemoglobin values are, on average, 0.5% higher in patients with LH and are significantly higher with incorrect rotation of sites and with needle reuse. Glycated hemoglobin values are lower in patients who distribute their injections over larger injection areas and whose sites are inspected routinely. The frequencies of unexpected hypoglycemia and glucose variability are significantly higher in those with LH, those injecting into LH, those who incorrectly rotate sites, and those who reuse needles. Needles associated with diabetes treatment are the most commonly used medical sharps in the world. However, correct disposal of sharps after use is critically suboptimal. Many used sharps end up in public trash and constitute a major accidental needlestick risk. Use of these data should stimulate renewed interest in and commitment to optimizing injection practices in patients with diabetes. Copyright © 2016 Mayo Foundation for Medical Education and Research. Published by Elsevier Inc. All rights reserved.

  5. Granisetron Injection

    Science.gov (United States)

    Granisetron immediate-release injection is used to prevent nausea and vomiting caused by cancer chemotherapy and to ... nausea and vomiting that may occur after surgery. Granisetron extended-release (long-acting) injection is used with ...

  6. Edaravone Injection

    Science.gov (United States)

    Edaravone injection is used to treat amyotrophic lateral sclerosis (ALS, Lou Gehrig's disease; a condition in which ... die, causing the muscles to shrink and weaken). Edaravone injection is in a class of medications called ...

  7. Defibrotide Injection

    Science.gov (United States)

    Defibrotide injection is used to treat adults and children with hepatic veno-occlusive disease (VOD; blocked blood ... the body and then returned to the body). Defibrotide injection is in a class of medications called ...

  8. Nalbuphine Injection

    Science.gov (United States)

    ... injection is in a class of medications called opioid agonist-antagonists. It works by changing the way ... suddenly stop using nalbuphine injection, you may experience withdrawal symptoms including restlessness; teary eyes; runny nose; yawning; ...

  9. Unilateral versus bilateral thyroarytenoid Botulinum toxin injections in adductor spasmodic dysphonia: a prospective study

    Science.gov (United States)

    Upile, Tahwinder; Elmiyeh, Behrad; Jerjes, Waseem; Prasad, Vyas; Kafas, Panagiotis; Abiola, Jesuloba; Youl, Bryan; Epstein, Ruth; Hopper, Colin; Sudhoff, Holger; Rubin, John

    2009-01-01

    Objectives In this preliminary prospective study, we compared unilateral and bilateral thyroarytenoid muscle injections of Botulinum toxin (Dysport) in 31 patients with adductor spasmodic dysphonia, who had undergone more than 5 consecutive Dysport injections (either unilateral or bilateral) and had completed 5 concomitant self-rated efficacy and complication scores questionnaires related to the previous injections. We also developed a Neurophysiological Scoring (NPS) system which has utility in the treatment administration. Method and materials Data were gathered prospectively on voice improvement (self-rated 6 point scale), length of response and duration of complications (breathiness, cough, dysphagia and total voice loss). Injections were performed under electromyography (EMG) guidance. NPS scale was used to describe the EMG response. Dose and unilateral/bilateral injections were determined by clinical judgment based on previous response. Time intervals between injections were patient driven. Results Low dose unilateral Dysport injection was associated with no significant difference in the patient's outcome in terms of duration of action, voice score (VS) and complication rate when compared to bilateral injections. Unilateral injections were not associated with any post treatment total voice loss unlike the bilateral injections. Conclusion Unilateral low dose Dysport injections are recommended in the treatment of adductor spasmodic dysphonia. PMID:19852852

  10. Unilateral versus bilateral thyroarytenoid Botulinum toxin injections in adductor spasmodic dysphonia: a prospective study

    Directory of Open Access Journals (Sweden)

    Abiola Jesuloba

    2009-10-01

    Full Text Available Abstract Objectives In this preliminary prospective study, we compared unilateral and bilateral thyroarytenoid muscle injections of Botulinum toxin (Dysport in 31 patients with adductor spasmodic dysphonia, who had undergone more than 5 consecutive Dysport injections (either unilateral or bilateral and had completed 5 concomitant self-rated efficacy and complication scores questionnaires related to the previous injections. We also developed a Neurophysiological Scoring (NPS system which has utility in the treatment administration. Method and materials Data were gathered prospectively on voice improvement (self-rated 6 point scale, length of response and duration of complications (breathiness, cough, dysphagia and total voice loss. Injections were performed under electromyography (EMG guidance. NPS scale was used to describe the EMG response. Dose and unilateral/bilateral injections were determined by clinical judgment based on previous response. Time intervals between injections were patient driven. Results Low dose unilateral Dysport injection was associated with no significant difference in the patient's outcome in terms of duration of action, voice score (VS and complication rate when compared to bilateral injections. Unilateral injections were not associated with any post treatment total voice loss unlike the bilateral injections. Conclusion Unilateral low dose Dysport injections are recommended in the treatment of adductor spasmodic dysphonia.

  11. Super long-term creep tests of advanced HP and IP rotor steels

    Energy Technology Data Exchange (ETDEWEB)

    Tchizhik, A A [The Polzunov Central Boiler and Turbine Institute, Department the Fatigue Life of Materials for Power Plans Equipment, St. Petersburg (Russian Federation)

    1999-12-31

    A creep model has been developed for predicting the long-term creep behavior, in excess of 200,000 h for advanced materials.The new creep theory is based on a continuum microdamage model and is used to calculate the fields of stress and strain and wedge and cavities damage in critical components of steam and gas turbines. The application of this new model increases the reliability and service life of modern turbines. The accuracy of the model to predict long - term creep behavior, creep ductility was verified using the data bank of super long-term creep tests of advanced materials. (orig.) 12 refs.

  12. Super long-term creep tests of advanced HP and IP rotor steels

    Energy Technology Data Exchange (ETDEWEB)

    Tchizhik, A.A. [The Polzunov Central Boiler and Turbine Institute, Department the Fatigue Life of Materials for Power Plans Equipment, St. Petersburg (Russian Federation)

    1998-12-31

    A creep model has been developed for predicting the long-term creep behavior, in excess of 200,000 h for advanced materials.The new creep theory is based on a continuum microdamage model and is used to calculate the fields of stress and strain and wedge and cavities damage in critical components of steam and gas turbines. The application of this new model increases the reliability and service life of modern turbines. The accuracy of the model to predict long - term creep behavior, creep ductility was verified using the data bank of super long-term creep tests of advanced materials. (orig.) 12 refs.

  13. A direct plasma injection system into an RFQ for clean and safe ion implantation

    International Nuclear Information System (INIS)

    Takeuchi, T.; Katayama, T.; Okamura, M.; Yano, K.; Sakumi, A.; Hattori, T.; Hayashizaki, N.; Jameson, R.A.

    2002-01-01

    A new injection system, direct plasma injection system, was tested and its principle was proved successfully. We found that one of advantages of this injection system was efficient consumption of source materials. Large portions of induced ions can be injected into a first stage accelerator. This feature is quite useful for ion implantation applications, because toxic exhaust gas can be eliminated. In order to utilize this system for industrial application, the feasibility of a boron injection scheme using a Nd:YAG laser system was investigated

  14. Numerical simulation in steam injection process by a mechanistic approach

    Energy Technology Data Exchange (ETDEWEB)

    De Souza, J.C.Jr.; Campos, W.; Lopes, D.; Moura, L.S.S. [Petrobras, Rio de Janeiro (Brazil)

    2008-10-15

    Steam injection is a common thermal recovery method used in very viscous oil reservoirs. The method involves the injection of heat to reduce viscosity and mobilize oil. A steam generation and injection system consists primarily of a steam source, distribution lines, injection wells and a discarding tank. In order to optimize injection and improve the oil recovery factor, one must determine the parameters of steam flow such as pressure, temperature and steam quality. This study focused on developing a unified mathematical model by means of a mechanistic approach for two-phase steam flow in pipelines and wells. The hydrodynamic and heat transfer mechanistic model was implemented in a computer simulator to model the parameters of steam injection while trying to avoid the use of empirical correlations. A marching algorithm was used to determine the distribution of pressure and temperature along the pipelines and wellbores. The mathematical model for steam flow in injection systems, developed by a mechanistic approach (VapMec) performed well when the simulated values of pressures and temperatures were compared with the values measured during field tests. The newly developed VapMec model was incorporated in the LinVap-3 simulator that constitutes an engineering supporting tool for steam injection wells operated by Petrobras. 23 refs., 7 tabs., 6 figs.

  15. Piezoelectric Injection Systems

    Science.gov (United States)

    Mock, R.; Lubitz, K.

    The origin of direct injection can be doubtlessly attributed to Rudolf Diesel who used air assisted injection for fuel atomisation in his first self-ignition engine. Although it became apparent already at that time that direct injection leads to reduced specific fuel consumption compared to other methods of fuel injection, it was not used in passenger cars for the moment because of its disadvantageous noise generation as the requirements with regard to comfort were seen as more important than a reduced specific consumption.

  16. Performance of CO2 enrich CNG in direct injection engine

    Science.gov (United States)

    Firmansyah, W. B.; Ayandotun, E. Z.; Zainal, A.; Aziz, A. R. A.; Heika, M. R.

    2015-12-01

    This paper investigates the potential of utilizing the undeveloped natural gas fields in Malaysia with high carbon dioxide (CO2) content ranging from 28% to 87%. For this experiment, various CO2 proportions by volume were added to pure natural gas as a way of simulating raw natural gas compositions in these fields. The experimental tests were carried out using a 4-stroke single cylinder spark ignition (SI) direct injection (DI) compressed natural gas (CNG) engine. The tests were carried out at 180° and 300° before top dead centre (BTDC) injection timing at 3000 rpm, to establish the effects on the engine performance. The results show that CO2 is suppressing the combustion of CNG while on the other hand CNG combustion is causing CO2 dissociation shown by decreasing CO2 emission with the increase in CO2 content. Results for 180° BTDC injection timing shows higher performance compared to 300° BTDC because of two possible reasons, higher volumetric efficiency and higher stratification level. The results also showed the possibility of increasing the CO2 content by injection strategy.

  17. Short-term consistency testing vs. long-term behavior

    International Nuclear Information System (INIS)

    Ebert, W.L.; Bakel, A.J.; Wolf, S.F.; Strachan, D.M.

    1997-01-01

    The authors conducted Product Consistency Tests (PCTs) with a surrogate low-activity waste (LAW) glass to (1) evaluate the possible use of various test conditions in a specification test for LAW waste forms, (2) measure the reproducibility of the test at low temperatures, and (3) determine if the rates calculated from 7-day PCTs bound the rates measured in PCT conducted for longer durations, which represent more advanced corrosion. The effects of temperature and pH on the dissolution rate in PCTs are much less than the effects observed in dilute solutions due to the buildup of dissolved glass components in the PCTs. The precision of replicate 7-day tests at 20 and 40 degrees C was limited by the analytical uncertainty. The dissolution rates at all temperatures decreased with the test duration initially. However, the dissolution rates in tests at 70 and 90 degrees C increased when certain alteration phases formed after about 100 and 500 days, respectively; the rates in some tests exceeded that measured in a 7-day PCT. While the 7-day PCT does not provide a bounding rate for this glass at 70 or 90 degrees C, tests for longer durations are needed to determine if a 7-day test provides a bounding rate at lower temperatures

  18. Usefulness of intra-articular botulinum toxin injections. A systematic review.

    Science.gov (United States)

    Khenioui, Hichem; Houvenagel, Eric; Catanzariti, Jean François; Guyot, Marc Alexandre; Agnani, Olivier; Donze, Cécile

    2016-03-01

    Botulinum toxin is a proven and widely used treatment for numerous conditions characterized by excessive muscular contractions. Recent studies have assessed the analgesic effect of botulinum toxin in joint pain and started to unravel its mechanisms. We searched the international literature via the Medline database using the term "intraarticular botulinum toxin injection" combined with any of the following terms: "knee", "ankle", "shoulder", "osteoarthritis", "adhesive capsulitis of the shoulder". Of 16 selected articles about intraarticular botulinum toxin injections, 7 were randomized controlled trials done in patients with osteoarthritis, adhesive capsulitis of the shoulder, or chronic pain after joint replacement surgery. Proof of anti-nociceptive effects was obtained in some of these indications and the safety and tolerance profile was satisfactory. The studies are heterogeneous. The comparator was usually a glucocorticoid or a placebo; a single study used hyaluronic acid. Pain intensity was the primary outcome measure. The number of randomized trials and sample sizes are too small to provide a satisfactory level of scientific evidence or statistical power. Unanswered issues include the effective dosage and the optimal dilution and injection modalities of botulinum toxin. Copyright © 2015 Société française de rhumatologie. Published by Elsevier SAS. All rights reserved.

  19. Thermorespiratory Response of West African Dwarf Does to Progestagen Injection

    Directory of Open Access Journals (Sweden)

    Ogundana, FA.

    2005-01-01

    Full Text Available The physiological responses in terms of respiration rate (RR and rectal temperature (RT of 30 West African Dwarf (WAD does were monitored after a single im injection of different doses of progestagens meant for synchronising oestrus. The treatments involved im injection of 1 2 ml of sterile water (Control; 2 25 mg Medroxy Progesterone Acetate, MPA; 3 50 mg MPA; 4 50 mg Progesterone and 5 100 mg progesterone. The RR and RT of each animal were measured at 9:00, 13:00 and 17:00 h for 21 days after each injection. In all the treatment groups the RT did not change significantly (P> 0.05 during the weeks following treatment. On the contrary the RR was significantly higher (P< 0.05 in the week after injection than in the pre-injection period. Both the RR and the RT were higher at 13:00 h and 17:00 h than at 9:00 h. The RR was more influenced by the animal body size than the RT, while the ambient temperature and humidity affected both the animal's RT and RR. These results indicate that the thermorespiratory function of WAD does under their native humid environment is not negatively affected by injecting ≤ 100 mg progesterone or ≤ 50 mg MPA to synchronize oestrus.

  20. Potential benefits of saturation cycle with two-phase refrigerant injection

    International Nuclear Information System (INIS)

    Lee, Hoseong; Hwang, Yunho; Radermacher, Reinhard; Chun, Ho-Hwan

    2013-01-01

    In this paper, a saturation cycle is proposed to enhance a vapor compression cycle performance by reducing thermodynamic losses associated with single phase gas compression and isenthalpic expansion. In order to approach the saturation cycle, a two-phase refrigerant injection technique is applied to the multi-stage cycle. This multi-stage cycle with different options is modeled, and its performance is evaluated under ASHRAE standard operating conditions for air conditioning systems. Moreover, the two-phase refrigerant injection cycle is compared with the typical vapor injection cycle which is utilizing the internal heat exchanger or the flash tank. Low GWP refrigerants are applied to this two-phase refrigerant injection cycle. In terms of the COP and its improvement, R123 has a higher potential than any other refrigerants in the multi-stage cycle. Lastly, practical ideas realizing the saturation cycle are discussed such as multi-stage phase separator, phase separator with helical structure inside, and injection location of the compressor. -- Highlights: • A saturation cycle is proposed to enhance the vapor compression cycle performance. • Two-phase refrigerant injection technique is applied to the multi-stage cycle. • Modeling results of the proposed cycle show the significant performance improvement. • Low GWP refrigerants are applied and R123 shows the highest performance. • New parameters, α and ε, are used to show the potential of the saturation cycle

  1. Increased Use of Injectable Contraception in Sub-Saharan Africa ...

    African Journals Online (AJOL)

    African Journal of Reproductive Health ... Data are analyzed here from 95 surveys conducted since 1980 in 38 sub-Saharan African countries, to determine past injectable trends in the context of alternative ... Most use is supplied through the public sector, which raises long term cost issues for health ministries and donors.

  2. Longitudinal Phonatory Characteristics after Botulinum Toxin Type A Injection.

    Science.gov (United States)

    Fisher, Kimberly V.; And Others

    1996-01-01

    A study investigated the long-term effects of a Botulinum Toxin Type A injection on the glottal competency of a man with adductor spasmodic dysphonia. Results suggest that change in degree of glottal adduction over time can be observed even when vocal instability is present within each recording session. (CR)

  3. Grammar tests increase the ability to lateralize language function in the Wada test.

    Science.gov (United States)

    Połczyńska, Monika; Curtiss, Susan; Walshaw, Particia; Siddarth, Prabha; Benjamin, Chris; Moseley, Brian D; Vigil, Celia; Jones, Michael; Eliashiv, Dawn; Bookheimer, Susan

    2014-12-01

    Grammar is a core component of the language system, yet it is rarely assessed during the Wada (intracarotid amobarbital) test. It is hypothesized that adding grammar tests to the recovery phase of the Wada test will increase our ability to lateralize language function. Sixteen individuals (nine females, fifteen right-handed, mean age 38.4 years, SD=10.7) with medically refractory temporal lobe epilepsy participated in the study. On EEG ten patients had seizures originating in the left hemisphere (LH), five in the right hemisphere (RH), and one was insufficiently lateralized. We included only patients who were LH-dominant on the standard test in the encoding phase of the Wada test. In the recovery phase of Wada testing the participants underwent evaluation with a standard language and a new test of grammar, the CYCLE-N. Ten patients underwent bilateral injections, six unilateral (one RH, five LH). As expected, injection in the LH decreased language performance to a greater extent than injection to the RH on both tests. However, the CYCLE-N produced more profound language deficits in the injected LH compared to the RH (p=0.01), whereas the standard tests did not cause such pronounced differences (p=0.2). The results suggest that the standard tests did not significantly differentiate the effects of the injections and the CYCLE-N, for the most part, did. Our results are of particular relevance to patients who are too obtunded to speak in the encoding phase. In sum, the CYCLE-N may be helpful in assessing hemispheric dominance for language. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. FIELD TEST PROGRAM TO DEVELOP COMPREHENSIVE DESIGN, OPERATING, AND COST DATA FOR MERCURY CONTROL SYSTEMS

    Energy Technology Data Exchange (ETDEWEB)

    Michael D. Durham

    2005-03-17

    that were varied included SO{sub 3} conditioning on/off, injection concentrations, and distribution spray patterns. The original test plan called for parametric testing of NORIT FGD carbon at 1, 3, and 10 lbs/MMacf. These injection concentrations were estimated based on results from the Pleasant Prairie tests that showed no additional mercury removal when injection concentrations were increased above 10 lbs/MMacf. The Brayton Point parametric test data indicated that higher injection concentrations would achieve higher removal efficiencies and should be tested. The test plan was altered to include testing at 20 lbs/MMacf. The first test at this higher rate showed very high removal across the second ESP (>80%). Unlike the ''ceiling'' phenomenon witnessed at Pleasant Prairie, increasing sorbent injection concentration resulted in further capture of vapor-phase mercury. The final phase of field-testing was a 10-day period of continuous injection of NORIT FGD carbon. During the first five days, the injection concentration was held at 10 lbs/MMacf, followed by nominally five days of testing at an injection concentration of 20 lbs/MMacf. The mercury removal, as measured by the semi-continuous emission monitors (S-CEM), varied between 78% and 95% during the 10 lbs/MMacf period and increased to >97% when the injection concentration was increased to 20 lbs/MMacf. During the long-term testing period, mercury measurements following EPA's draft Ontario Hydro method were conducted by TRC Environmental Corporation at both 10 and 20 lbs/MMacf test conditions. The Ontario Hydro data showed that the particulate mercury removal was similar between the two conditions of 10 or 20 lbs/MMacf and removal efficiencies were greater than 99%. Elemental mercury was not detected in any samples, so no conclusions as to its removal can be drawn. Removal of oxidized mercury, on the other hand, increased from 68% to 93% with the higher injection concentration. These removal

  5. Test plan for long-term, low-temperature oxidation of spent fuel, Series 1

    International Nuclear Information System (INIS)

    Einziger, R.E.

    1986-06-01

    Preliminary studies indicated the need for more spent fuel oxidation data in order to determine the probable behavior of spent fuel in a tuff repository. Long-term, low-temperature testing was recommended in a comprehensive technical approach to: (1) confirm the findings of the short-term thermogravimetric analyses scoping experiments; (2) evaluate the effects of variables such as burnup, atmospheric moisture and fuel type on the oxidation rate; and (3) extend the oxidation data base ot representative repository temperatures and better define the temperature dependence of the operative oxidation mechanisms. This document presents the Series 1 test plan to study, on a large number of samples, the effects of atmospheric moisture and temperature on oxidation rate and phase formation. Tests will run for up to two years, use characterized fragmented, and pulverized fuel samples, cover a temperature range of 110 0 C to 175 0 C and be conducted with an atmospheric moisture content rangeing from 0 C to approx. 80 0 C dew point. After testing, the samples will be examined and made available for leaching testing

  6. Injection molding of bushes made of tribological PEEK composites

    Directory of Open Access Journals (Sweden)

    2007-12-01

    Full Text Available Polyetheretherketone (PEEK composites have been extensively studied because of the excellent tribological behavior among plastics. However, laboratory specimens and tests are generally discussed, whereas application studies on industrial components are infrequent. In this paper, an injection molded bush made of tribological PEEK was analyzed to correlate wear behavior and molded material structure. Bushes were tested under unlubricated sliding conditions by means of a short wear test. Surface analysis, differential scanning calorimetry (DSC and optical microscopy were used to evaluate the distribution of the different composite fillers (polytetrafluoroethylene, PTFE, graphite particles and carbon microfibers and their effect on the final bush behavior. A significant lack of homogeneity was observed in the molded bush and black bands appeared on the shaft surface after testing due to the sliding. The bush geometry and the injection molding process should be optimized to allow the best tribological behavior of the molded material under working conditions.

  7. Glaukos iStent inject® Trabecular Micro-Bypass Implantation Associated with Cataract Surgery in Patients with Coexisting Cataract and Open-Angle Glaucoma or Ocular Hypertension: A Long-Term Study

    Directory of Open Access Journals (Sweden)

    Pedro Arriola-Villalobos

    2016-01-01

    Full Text Available Purpose. To evaluate the long-term efficacy and safety of the iStent inject device (Glaukos Corporation, Laguna Hills, CA combined with phacoemulsification in patients with coexistent cataract and open-angle glaucoma or ocular hypertension (OHT. Methods. A prospective, uncontrolled, nonrandomized, interventional case series study was conducted in patients with both mild or moderate open-angle glaucoma or OHT and cataract. Patients underwent cataract surgery along with the implant of two iStent inject devices. Outcome measures were intraocular pressure (IOP, topical hypotensive medications required, and best-corrected visual acuity (BCVA. Results. 20 patients were enrolled. Mean follow-up was 47.4±18.46 months. Mean baseline IOP was 19.95±3.71 mmHg with medication and 26±3.11 mmHg after washout. Mean end-follow-up IOP was 16.25±1.99 mmHg, representing an IOP decrease of 36.92%, 9.74±3.14 mmHg (P<0.001, from baseline washout IOP. The mean number of medications was significantly reduced from 1.3±0.66 to 0.75±0.79 (P=0.017. 45% of patients were medication-free by the end of follow-up. Mean log⁡MAR BCVA improved significantly from 0.42±0.16 to 0.18±0.16 (P<0.001. No complications of surgery were observed. Conclusion. The iStent inject device combined with cataract surgery served to significantly reduce both IOP and medication use in the long term in patients with coexistent open-angle glaucoma or ocular hypertension (OHT and cataract.

  8. Zinc injection in German PWR plants

    International Nuclear Information System (INIS)

    Streit, K.

    2004-01-01

    Operating experience acquired at PWR NNPs shows that zinc injection at low concentrations of 5 ppb is a very effective source term reduction measure. This method does not lead to any operating restrictions or other negative effects on plant systems and components. The nuclear industry has been very successful in reducing radiation exposures within the past two decades. Annual exposures could be significantly decreased and are now at a level of around 1 man-Sv per plant and year. This great success can mainly be attributed to the general commitment of plant operators to maintaining radiation exposures of workers in the controlled access area as low as reasonably achievable (ALARA principle). The ALARA principle, of course, also implies evaluation of the economic benefit of radiation protection measures. Radiation source term reduction has drawn increasing attention of plant operators in recent years. For the new PWRs cobalt-based alloys in the primary system have successively been eliminated already at the design and construction phase within the last decade. Use of wear-resistant cobalt-free substitute materials in combination with the general use of advanced alloys for the steam generator tubing of PWRs resulted in low values for the two most common sources of plant radiation fields, namely 58 Co and 60 Co. Investigations showed that the beneficial effect of zinc can be related to its high affinity for mixed spinel oxide phases, resulting in the following two basic effects: -Zinc is incorporated preferentially into the oxide layer on primary system surfaces and thus reduces pickup of 58 Co and 60 Co and - Zinc can displace cobalt isotopes from existing oxide layers. In German PWRs with Incoloy 800 steam generator tubing material (Ni-content -32%), the observed reductions correspond to a decrease in dose rates of around 10 to 15% per year and thus follow, as predicted, the half-life time of 60 Co. Overall reductions in high radiation areas are now in the range of

  9. Rate of Post-traumatic Endophthalmitis with or without Injection of Balanced Salt Solution

    Directory of Open Access Journals (Sweden)

    Nasrin Rafati

    2013-01-01

    Full Text Available Purpose: In a study complementing a previous multicenter randomized clinical trial on prophylactic injection of intraocular antibiotics during primary repair of penetrating eye injuries (PEIs, we sought to determine whether needle entrance and injection of balanced salt solution (BSS, per se, could increase the rate of acute post-traumatic bacterial endophthalmitis (APBE. Methods: Patients randomized to the BSS injection arm (n=167 of the Traumatic Endophthalmitis Trial, and eligible patients who had refused enrollment and received no intraocular injections during primary repair (n=111 were compared for the development of APBE. Results: APBE occurred in 8 of 167 (4.8% eyes in the BSS group and in 5 of 111 (4.5% eyes in the non-injection group (P=0.91. Retained intraocular foreign bodies were present in 46 eyes including 25 (15% eyes in the BSS injection group and 21 (18.9% eyes in the non-injection group (P=0.38. Logistic regression analysis showed no significant difference between BSS injected and non-injected eyes in terms of APBE (P=0.69. However, the presence of intraocular foreign bodies was strongly associated with the risk of endophthalmitis (P<0.001, OR=14.1, 95% CI: 4.1-48.5. Conclusion: Needle entrance and intraocular injection of BSS during primary repair of PEIs does not increase the risk of APBE.

  10. Short and long term bystander effect induction by fathead minnows (Pimephales promelas, Rafinesque, 1820) injected with environmentally relevant whole body doses of 226Ra

    International Nuclear Information System (INIS)

    Smith, Richard W.; Seymour, Colin B.; Mothersill, Carmel E.

    2013-01-01

    Bystander effect induction by fathead minnows injected with environmentally relevant doses of 226 Ra was investigated. Twenty four h and 6 months after injection with a single dose of 21, 210 or 2100 μBq, fin tissue samples emitted a pro-apoptotic signal, which reduced the clonogenic survival of an apoptosis sensitive reporter cell line. Twenty four h and 10 weeks after injection explants from non-injected bystander fish, swum with the injected fish, also emitted a pro-apoptotic signal. However 6 months after injection the bystander fish to 21 and 210 μBq injected fish emitted an anti-apoptotic signal. This demonstrates that extremely low dose irradiation can have effects outside of the irradiated fish. This has implications for population and ecosystem responses to contamination. -- Highlights: • Non-injected fish, swum with injected fish, gave the same response for up to 10 weeks. • After 6 months this response by non-injected fish changed to an anti-apoptotic signal. • This shows that 226 Ra contamination can have effects outside of the irradiated fish

  11. Ultrasound-guided therapeutic injections for neural pathology about the foot and ankle: a 4 year retrospective review.

    Science.gov (United States)

    Walter, William R; Burke, Christopher J; Adler, Ronald S

    2017-06-01

    To describe a 4-year clinical experience with ultrasound-guided therapeutic perineural injections of peripheral nerves about the foot and ankle. Retrospective analysis of foot and ankle perineural injections performed between January 2012 and August 2016. Demographics, clinical indications, presence of structural pathology, immediate and interval pain relief, as well as complications were recorded. Fifty-nine therapeutic injections were performed among 46 patients, accounting for multiple injections in a single visit or multiple visits [mean age = 43 years (range 18-75), 31 female (67%) and 15 male (33%)]. Most commonly, perineural injections involved the hallux branch of the medial plantar nerve (n = 17, 22%). Least commonly, perineural injections involved the saphenous nerve (n = 3, 4%). Other injections in our series include sural (10), superficial (11) and deep (7) peroneal, medial (5) and lateral (3) plantar nerves, and the posterior tibial nerve (3). Ultrasound evaluation revealed structural abnormality associated with the nerve in 30 cases (51%)-most commonly thickening with perineural scarring (n = 14). Of 45 injections with complete documentation, immediate relief of symptoms was reported in 43 (96%) cases. Interval symptom relief was achieved in 23 injections [short term (n = 12), intermediate (n = 6), and long term (n = 5)] out of 38 for which follow-up was available (61%). Complications are rare, occurring in only one case. Ultrasound-guided perineural injections about the foot and ankle are safe and provide lasting symptomatic relief for many indications. Concomitant sonographic evaluation identifies structural abnormalities that may contribute to neuropathic symptoms, allowing targeting of injection or clinical therapy.

  12. Experimental study of curved guide tubes for pellet injection

    International Nuclear Information System (INIS)

    Combs, S.K.; Baylor, L.R.; Foust, C.R.; Gouge, M.J.; Jernigan, T.C.; Milora, S.L.

    1997-01-01

    The use of curved guide tubes for transporting frozen hydrogen pellets offers great flexibility for pellet injection into plasma devices. While this technique has been previously employed, an increased interest in its applicability has been generated with the recent ASDEX Upgrade experimental data for magnetic high-field side (HFS) pellet injection. In these innovative experiments, the pellet penetration appeared to be significantly deeper than for the standard magnetic low-field side injection scheme, along with corresponding greater fueling efficiencies. Thus, some of the major experimental fusion devices are planning experiments with HFS pellet injection. Because of the complex geometries of experimental fusion devices, installations with multiple curved guide tube sections will be required for HFS pellet injection. To more thoroughly understand and document the capability of curved guide tubes, an experimental study is under way at the Oak Ridge National Laboratory (ORNL). In particular, configurations and pellet parameters applicable for the DIII-D tokamak and the International Thermonuclear Experimental Reactor (ITER) were simulated in laboratory experiments. Initial test results with nominal 2.7- and 10-mm-diam deuterium pellets are presented and discussed

  13. Preparation and evaluation of a phospholipid-based injectable gel for the long term delivery of leuprolide acetaterrh.

    Science.gov (United States)

    Long, Danhong; Gong, Tao; Zhang, Zhirong; Ding, Rui; Fu, Yao

    2016-07-01

    A phospholipid-based injectable gel was developed for the sustained delivery of leuprolide acetate (LA). The gel system was prepared using biocompatible materials (SPME), including soya phosphatidyl choline (SPC), medium chain triglyceride (MCT) and ethanol. The system displayed a sol state with low viscosity in vitro and underwent in situ gelation in vivo after subcutaneous injection. An in vitro release study was performed using a dialysis setup with different release media containing different percentages of ethanol. The stability of LA in the SPME system was investigated under different temperatures and in the presence of various antioxidants. In vivo studies in male rats were performed to elucidate the pharmacokinetic profiles and pharmacodynamic efficacy. A sustained release of LA for 28 days was observed without obvious initial burst in vivo. The pharmacodynamic study showed that once-a-month injection of LA-loaded SPME (SPME-LA) led to comparable suppression effects on the serum testosterone level as observed in LA solution except for the onset time. These findings demonstrate excellent potential for this novel SPME system as a sustained release delivery system for LA.

  14. Influence of gas injection on viscous and viscoelastic properties of Xanthan gum.

    Science.gov (United States)

    Bobade, Veena; Cheetham, Madalyn; Hashim, Jamal; Eshtiaghi, Nicky

    2018-05-01

    Xanthan gum is widely used as a model fluid for sludge to mimic the rheological behaviour under various conditions including impact of gas injection in sludge. However, there is no study to show the influence of gas injection on rheological properties of xanthan gum specifically at the concentrations at which it is used as a model fluid for sludge with solids concentration above 2%. In this paper, the rheological properties of aqueous xanthan gum solutions at different concentrations were measured over a range of gas injection flow rates. The effect of gas injection on both the flow and viscoelastic behaviour of Xanthan gum (using two different methods - a creep test and a time sweep test) was evaluated. The viscosity curve of different solid concentrations of digested sludge and waste activated sludge were compared with different solid concentrations of Xanthan gum and the results showed that Xanthan gum can mimic the flow behaviour of sludge in flow regime. The results in linear viscoelastic regime showed that increasing gas flow rate increases storage modulus (G'), indicating an increase in the intermolecular associations within the material structure leading to an increase in material strength and solid behaviour. Similarly, in creep test an increase in the gas flow rate decreased strain%, signifying that the material has become more resistant to flow. Both observed behaviour is opposite to what occurs in sludge under similar conditions. The results of both the creep test and the time sweep test indicated that choosing Xanthan gum aqueous solution as a transparent model fluid for sludge in viscoelastic regime under similar conditions involving gas injection in a concentration range studied is not feasible. However Xanthan gum can be used as a model material for sludge in flow regime; because it shows a similar behaviour to sludge. Copyright © 2018 Elsevier Ltd. All rights reserved.

  15. Long-term tissue distribution and steady state activity ratios of 232Th and its daughters in rats after intravascular injection of thorotrast

    International Nuclear Information System (INIS)

    Norimura, Toshiyuki; Tsuchiya, Takehiko; Hatakeyama, Satoru; Yamamoto, Hisao; Okajima, Shunzo.

    1989-01-01

    To estimate the absorbed dose in the critical organs of Thorotrast patients, it is necessary to know not only the distribution and concentration of 232 Th but also its daughter nuclides in the body. The present investigation was undertaken in order to clarify the long-term 232 Th tissue distribution and steady state activity ratios between subsequent daughters in the critical tissues, using about 30 Wister male rats, as a basis for estimating absorbed doses. The tissue distribution of thorium was examined by means of an autoradiographty of the whole body and/or the gamma-ray spectrometry at various times during 2 to 24 months following injection. The concentrations of daughter nuclides in tissues were determined by repetitive gamma examination over a period from 1 hr to 35 days after being sacrificed. The data indicate (1) that approximately 90% of injected Thorotrast is retained in the body for a prolonged period, but about 50% of radium and 10% of radon produced from thorium are eliminated from the body, (2) that the mean steady state activity ratios of 224 Ra and 212 Pb to 228 Th for liver are 0.56 and 0.28, and 0.54 and 0.16 for spleen, 0.58 and 0.82 for lungs, respectively, and (3) that the parent 228 Th is translocated to the bone. (author)

  16. A comparison of molding procedures - Contact, injection and vacuum injection

    Science.gov (United States)

    Cathiard, G.

    1980-06-01

    The technical and economic aspects of the contact, injection and vacuum injection molding of reinforced plastic components are compared for the example of a tractor roof with a gel-coated surface. Consideration is given to the possibility of reinforcement, number of smooth faces, condition of the gel-coated surface, reliability, and labor and workplace requirements of the three processes, and advantages of molding between the mold and a countermold in smooth faces, reliability, labor requirements, working surface and industrial hygiene are pointed out. The times and labor requirements of each step in the molding cycles are examined, and material requirements and yields, investment costs, amortization and product cost prices of the processes are compared. It is concluded that, for the specific component examined, the processes of vacuum injection and injection molding appear very interesting, with injection molding processes resulting in lower cost prices than contact molding for any production volume.

  17. Prevalence of injections and knowledge of safe injections among rural residents in Central China.

    Science.gov (United States)

    Yan, Y W; Yan, J; Zhang, G P; Gao, Z L; Jian, H X

    2007-08-01

    Abuse of the injection services, namely unnecessary injections and unsafe injections, exists extensively in developing countries. Unsafe injection practices contribute to the transmission of blood-borne pathogens. The aims of this study were to survey the prevalence of injections and knowledge of injection safety among the rural residents in Jingzhou district, Hubei, China and to provide scientific data for developing a health educational programme. A retrospective cross-sectional study was conducted in 12 villages, which were selected from the Jingzhou district by the random sampling method. 50 rural residents were interviewed per village using a questionnaire. Among the 595 residents studied, 192 had received at least one injection in the past three months, with an injection prevalence of 32.3 percent and an average of 0.93 injections. 90.3 percent of the rural residents knew that unsafe injections could transmit the following blood-borne pathogens: human immunodeficiency virus (74.4 percent), hepatitis B virus (55.8 percent) and hepatitis C virus (22.9 percent). Logistic regression analysis showed that the residents' age, educational level and residential area were important factors in influencing their knowledge about injection safety. The results indicated that the injection prevalence was high among rural residents in the study area, and their knowledge regarding injection safety should be further improved.

  18. MgO by injection CVD

    International Nuclear Information System (INIS)

    Abrutis, A.; Kubilius, V.; Teiserkis, A.; Bigelyte, V.; Vengalis, B.; Jukna, A.; Butkute, R.

    1997-01-01

    Epitaxial YBa 2 Cu 3 O 7 layers with 45 in-plane orientation have been grown by injection CVD on MgO substrates polished off-axis to within 1.4-1.9 of the [100] direction. This new single-source CVD process is based on computer-controlled injection of precise microdoses of a metal-organic precursor solution into a CVD reactor. A wide range of solution compositions was tested to investigate compositional effects on phase purity, surface morphology, texturing and superconducting properties of the prepared films. The highest quality films with pure 45 texture had a smooth surface, zero resistance T c (R=0) of 88-89 K, and critical current density J c (77 K) above 10 6 A/cm 2 . (orig.) and critical current density J c (77 K) above 10 6 A/cm 2 . (orig.)

  19. Injection-controlled laser resonator

    Science.gov (United States)

    Chang, J.J.

    1995-07-18

    A new injection-controlled laser resonator incorporates self-filtering and self-imaging characteristics with an efficient injection scheme. A low-divergence laser signal is injected into the resonator, which enables the injection signal to be converted to the desired resonator modes before the main laser pulse starts. This injection technique and resonator design enable the laser cavity to improve the quality of the injection signal through self-filtering before the main laser pulse starts. The self-imaging property of the present resonator reduces the cavity induced diffraction effects and, in turn, improves the laser beam quality. 5 figs.

  20. Long-term leach testing of solidified radioactive waste forms (International Standard Publication ISO 6961:1982)

    International Nuclear Information System (INIS)

    Stefanik, J.

    2001-01-01

    Processes are developed for the immobilization of radionuclides by solidification of radioactive wastes. The resulting solidification products are characterized by strong resistance to leaching aimed at low release rates of the radionuclides to the environment. To measure this resistance to leaching of the solidified materials: glass, glass-ceramics, bitumen, cement, concrete, plastics, a long-term leach test is presented. The long-term leach test is aimed at: a) the comparison of different kinds or compositions of solidified waste forms; b) the intercomparison between leach test results from different laboratories on one product; c) the intercomparison between leach test results on products from different processes