WorldWideScience

Sample records for term injection tests

  1. Injection Tests

    CERN Document Server

    Kain, V

    2009-01-01

    The success of the start-up of the LHC on 10th of September was in part due to the preparation without beam and injection tests in 2008. The injection tests allowed debugging and improvement in appropriate portions to allow safe, efficient and state-of-the-art commissioning later on. The usefulness of such an approach for a successful start-up becomes obvious when looking at the problems we encountered before and during the injection tests and could solve during this period. The outline of the preparation and highlights of the different injection tests will be presented and the excellent performance of many tools discussed. A list of shortcomings will follow, leading to some planning for the preparation of the run in 2009.

  2. Strontium isotopes test long-term zonal isolation of injected and Marcellus formation water after hydraulic fracturing.

    Science.gov (United States)

    Kohl, Courtney A Kolesar; Capo, Rosemary C; Stewart, Brian W; Wall, Andrew J; Schroeder, Karl T; Hammack, Richard W; Guthrie, George D

    2014-08-19

    One concern regarding unconventional hydrocarbon production from organic-rich shale is that hydraulic fracture stimulation could create pathways that allow injected fluids and deep brines from the target formation or adjacent units to migrate upward into shallow drinking water aquifers. This study presents Sr isotope and geochemical data from a well-constrained site in Greene County, Pennsylvania, in which samples were collected before and after hydraulic fracturing of the Middle Devonian Marcellus Shale. Results spanning a 15-month period indicated no significant migration of Marcellus-derived fluids into Upper Devonian/Lower Mississippian units located 900-1200 m above the lateral Marcellus boreholes or into groundwater sampled at a spring near the site. Monitoring the Sr isotope ratio of water from legacy oil and gas wells or drinking water wells can provide a sensitive early warning of upward brine migration for many years after well stimulation.

  3. Long-Term Carbon Injection Field Test for 90% Mercury Removal for a PRB Unit a Spray Dryer and Fabric Filter

    Energy Technology Data Exchange (ETDEWEB)

    Sjostrom, Sharon; Amrhein, Jerry

    2009-04-30

    The power industry in the U.S. is faced with meeting regulations to reduce the emissions of mercury compounds from coal-fired plants. Injecting a sorbent such as powdered activated carbon (PAC) into the flue gas represents one of the simplest and most mature approaches to controlling mercury emissions from coal-fired boilers. The purpose of this test program was to evaluate the long-term mercury removal capability, long-term mercury emissions variability, and operating and maintenance (O&M) costs associated with sorbent injection on a configuration being considered for many new plants. Testing was conducted by ADA Environmental Solutions (ADA) at Rocky Mountain Power’s (RMP) Hardin Station through funding provided by DOE/NETL, RMP, and other industry partners. The Hardin Station is a new plant rated at 121 MW gross that was first brought online in April of 2006. Hardin fires a Powder River Basin (PRB) coal and is configured with selective catalytic reduction (SCR) for NOx control, a spray dryer absorber (SDA) for SO2 control, and a fabric filter (FF) for particulate control. Based upon previous testing at PRB sites with SCRs, very little additional mercury oxidation from the SCR was expected at Hardin. In addition, based upon results from DOE/NETL Phase II Round I testing at Holcomb Station and results from similarly configured sites, low native mercury removal was expected across the SDA and FF. The main goal of this project was met—sorbent injection was used to economically and effectively achieve 90% mercury control as measured from the air heater (AH) outlet to the stack for a period of ten months. This goal was achieved with DARCO® Hg-LH, Calgon FLUEPAC®-MC PLUS and ADA Power PAC PREMIUM brominated activated carbons at nominal loadings of 1.5–2.5 lb/MMacf. An economic analysis determined the twenty-year levelized cost to be 0.87 mills/kW-hr, or $15,000/lb Hg removed. No detrimental effects on other equipment or plant operations were observed. The

  4. Injection grout for deep repositories. Subproject 1: LowpH cementitious grout for larger fractures, leach testing of grout mixes and evaluation of the long-term safety

    International Nuclear Information System (INIS)

    Vuorinen, U.; Lehikoinen, J.; Imoto, Harutake; Yamamoto, Takeshi; Cruz Alonso, M.

    2005-10-01

    Constructing an underground disposal facility for spent nuclear fuel deep in bedrock requires lowpH cement-based injection grout, because assured data of the extent of a possible high-pH plume in saturated bedrock conditions is lacking. In this work low-pH grout mixes of new design were subjected to leach testing. Before chosen to leach testing the grout mixes had to fulfil certain technical requirements. Leach testing was performed in order to establish that the pH requirement (≤11) set for the leachates was met. For comparison reasons also one conventionally used cement based grout material was included in the tests. Two kinds of lowpH grout cement mixes were tested; mixes with added blast furnace slag (4 mixes) or added silica (6 mixes). All the mixes were not completely tested according to the test plan, because for some mixes during leach testing factors detrimental to the long-term safety of a repository were observed, e.g. too high pH or leached sulphide, which is harmful for copper. Leach testing of the grout mixes was performed in a glove-box (N 2 atmosphere) in order to avoid the interference of atmospheric CO 2 on the alkaline leachates. Two simulated groundwater solutions, saline OL-SO and fresh ALL-MR, were used as leachates. Two leach tests were applied; equilibrium and diffusion tests. In the equilibrium test at each measuring point only a part of the leachate was exchanged, whereas in the diffusion test the entire leachate was exchanged. The pH value of each leachate sample was measured, but total alkalinity was determined only for some leachates. Na, K, Ca, Mg, Al, Fe, Si, SO 4 2- , S TOT , and Cl were analysed in the leach solutions collected in the diffusion test of four grout mixes chosen. Also the corresponding solid specimens were analysed (SEM, XRD, EPMA, MIP, TG) in Japan. A few grout pore fluid pH values were measured in Spain, as well. The simplified thermodynamic model calculations were successful in qualitatively reproducing the

  5. Large scale injection test (LASGIT) modelling

    International Nuclear Information System (INIS)

    Arnedo, D.; Olivella, S.; Alonso, E.E.

    2010-01-01

    Document available in extended abstract form only. With the objective of understanding the gas flow processes through clay barriers in schemes of radioactive waste disposal, the Lasgit in situ experiment was planned and is currently in progress. The modelling of the experiment will permit to better understand of the responses, to confirm hypothesis of mechanisms and processes and to learn in order to design future experiments. The experiment and modelling activities are included in the project FORGE (FP7). The in situ large scale injection test Lasgit is currently being performed at the Aespoe Hard Rock Laboratory by SKB and BGS. An schematic layout of the test is shown. The deposition hole follows the KBS3 scheme. A copper canister is installed in the axe of the deposition hole, surrounded by blocks of highly compacted MX-80 bentonite. A concrete plug is placed at the top of the buffer. A metallic lid anchored to the surrounding host rock is included in order to prevent vertical movements of the whole system during gas injection stages (high gas injection pressures are expected to be reached). Hydration of the buffer material is achieved by injecting water through filter mats, two placed at the rock walls and two at the interfaces between bentonite blocks. Water is also injected through the 12 canister filters. Gas injection stages are performed injecting gas to some of the canister injection filters. Since the water pressure and the stresses (swelling pressure development) will be high during gas injection, it is necessary to inject at high gas pressures. This implies mechanical couplings as gas penetrates after the gas entry pressure is achieved and may produce deformations which in turn lead to permeability increments. A 3D hydro-mechanical numerical model of the test using CODE-BRIGHT is presented. The domain considered for the modelling is shown. The materials considered in the simulation are the MX-80 bentonite blocks (cylinders and rings), the concrete plug

  6. Lightning Pin Injection Testing on MOSFETS

    Science.gov (United States)

    Ely, Jay J.; Nguyen, Truong X.; Szatkowski, George N.; Koppen, Sandra V.; Mielnik, John J.; Vaughan, Roger K.; Wysocki, Philip F.; Celaya, Jose R.; Saha, Sankalita

    2009-01-01

    Lightning transients were pin-injected into metal-oxide-semiconductor field-effect transistors (MOSFETs) to induce fault modes. This report documents the test process and results, and provides a basis for subsequent lightning tests. MOSFETs may be present in DC-DC power supplies and electromechanical actuator circuits that may be used on board aircraft. Results show that unprotected MOSFET Gates are susceptible to failure, even when installed in systems in well-shielded and partial-shielded locations. MOSFET Drains and Sources are significantly less susceptible. Device impedance decreased (current increased) after every failure. Such a failure mode may lead to cascading failures, as the damaged MOSFET may allow excessive current to flow through other circuitry. Preliminary assessments on a MOSFET subjected to 20-stroke pin-injection testing demonstrate that Breakdown Voltage, Leakage Current and Threshold Voltage characteristics show damage, while the device continues to meet manufacturer performance specifications. The purpose of this research is to develop validated tools, technologies, and techniques for automated detection, diagnosis and prognosis that enable mitigation of adverse events during flight, such as from lightning transients; and to understand the interplay between lightning-induced surges and aging (i.e. humidity, vibration thermal stress, etc.) on component degradation.

  7. RELAP5 analysis of PACTEL injection tests

    International Nuclear Information System (INIS)

    Kimber, G.R.; Lillington, J.N.

    2000-01-01

    A characteristic feature of advanced reactor designs is their reliance on passive safety systems. It is important to assess both the operation of such systems and the ability of systems codes, such as RELAP5, to model them. In Finland VTT Energy, together with Lappeenranta University of Technology, is using the PACTEL facility for the investigation of passive core cooling systems. In particular, a core make-up tank (CMT) has been installed in the rig to operate in a similar manner to those in many Advanced PWR designs. Three small break tests, GDE-24, GDE-34 and GDE-43 in the PACTEL facility were chosen for modelling with RELAP5. The objective of GDE-24 was to investigate CMT behaviour and in particular the effects of condensation in the CMT. The second test, GDE-34, was similar except that it had a smaller CMT and at the start of the test the water in the CMT and connecting pipework was at an elevated temperature. Test GDE-43 focused on conditions when the driving force for flow through the passive system injection system (PSIS) slowly disappears. Analysis of all tests reported here was carried out with RELAP5/MOD 3.2.1.2. The paper summarises the conclusions of all the tests. A critical part of the study revolved around modelling of the CMT. A model was developed to allow its detailed behaviour to be investigated more easily. This enabled recommendations for improving the condensation modelling in RELAP5 to be made. Apart from the wall condensation modelling issue, the implication of the work is that RELAP5/MOD 3.2.1.2 (a comparatively recent version of the code) is broadly adequate for these applications. (author)

  8. Injecting Errors for Testing Built-In Test Software

    Science.gov (United States)

    Gender, Thomas K.; Chow, James

    2010-01-01

    Two algorithms have been conceived to enable automated, thorough testing of Built-in test (BIT) software. The first algorithm applies to BIT routines that define pass/fail criteria based on values of data read from such hardware devices as memories, input ports, or registers. This algorithm simulates effects of errors in a device under test by (1) intercepting data from the device and (2) performing AND operations between the data and the data mask specific to the device. This operation yields values not expected by the BIT routine. This algorithm entails very small, permanent instrumentation of the software under test (SUT) for performing the AND operations. The second algorithm applies to BIT programs that provide services to users application programs via commands or callable interfaces and requires a capability for test-driver software to read and write the memory used in execution of the SUT. This algorithm identifies all SUT code execution addresses where errors are to be injected, then temporarily replaces the code at those addresses with small test code sequences to inject latent severe errors, then determines whether, as desired, the SUT detects the errors and recovers

  9. Large scale gas injection test (Lasgit): Results from two gas injection tests

    International Nuclear Information System (INIS)

    Cuss, R. J.; Harrington, J. F.; Noy, D. J.; Wikman, A.; Sellin, P.

    2011-01-01

    This paper describes the initial results from a large scale gas injection test (Lasgit) performed at the Aespoe Hard Rock Laboratory (Sweden)). Lasgit is a full-scale field-scale experiment based on the Swedish KBS-3V repository concept, examining the processes controlling gas and water flow in compact buffer bentonite. The first 2 years of the test focused on the artificial hydration of the bentonite buffer. This was followed by a programme of hydraulic and gas injection tests which ran from day 843 to 1110. A further period of artificial hydration occurred from day 1110 to 1385, followed by a more complex programme of gas injection testing which remains on going (day 1385+). After 2 years of hydration, hydraulic conductivity and specific storage values in the lower filter array were found to range from 9 x 10 -14 to 1.6 x 10 -13 m/s and 5.5 x 10 -5 to 4.4 x 10 -4 m -1 respectively, with the injection filter FL903 yielding values of 7.5 x 10 -14 m/s and 2.5 x 10 -5 m -1 . A second set of hydraulic measurements were performed over 1 year and a half later yielding similar values, in the range 7.8 x 10 -14 m/s and 1.3 x 10 -13 m/s. The hydraulic conductivity of FL903 had reduced slightly to 5.3 x 10 -14 m/s while specific storage had increased to 4.0 x 10 -5 m -1 . Both datasets agree with laboratory values performed on small-scale saturated samples. Two sets of gas injection tests were performed over a 3 year period. During the course of testing, gas entry pressure was found to increase from around 650 kPa to approximately 1.3 MPa, indicative of the maturation of the clay. The sequential reduction in volumetric flow rate and lack of correlation between the rate of gas inflow and the gas pressure gradient observed during constant pressure steps prior to major gas entry, is suggestive of a reduction in gas permeability of the buffer and indicates only limited quantities of gas can be injected into the clay without interacting with the continuum stress field. Major gas

  10. Permeability of fissured rock - an experimental study with special regard to the water injection test

    International Nuclear Information System (INIS)

    Schneider, H.J.

    1987-01-01

    The permeability to water of fissured rock is one of the most important design parameters for many underground projects, such as, e.g. the final deposition of radioactive waste. Because the conventional water injection test according to LUGEON for the calculation of permeability to water is associated with a high degree of uncertainty, new test equipment was developed. This equipment works on the principle of the water injection tracer test and multi-level measurements, enabling detailed measurement of the flow process at injection site and in the rock. The tests were carried out in Bunter sandstone and granite. The LUGEON test concept was varied in short-term and long-term tests at identical geological boundary conditions, and with test control at constant pressure on the one hand and at constant injection volume on the other. The test results show that non-steady-state flow occurs with short injection times, whereby the range is limited to the local rock at injection site. An increasing in injection time can lead to an increase in range by a number of factors as well as to steady-state flow conditions. The permeability of the rock types investigated is inhomgeneous and anistropic as a result of the fissured structure. (orig./HP) With 114 figs., 4 tabs [de

  11. Small-scale bentonite injection test on rock

    International Nuclear Information System (INIS)

    Pusch, R.

    1978-03-01

    When radiactive waste is disposed a sealing of the rock is very valuable since it reduces the rate of water percolation and diffusion. In an earlier report injection of bentonite gels by means of over-pressure and subsequent electrophoresis has been suggested. The present report describes a rock test series where bentonite injection was applied. For the test an approximately cubical block of about 1 m 3 was selected. The rock type was diorite with a fairly high frequency of quartz denses. The block was kept in a basin during the test in order to maintain the water saturation. Holes were bored in the block. A bentonite slurry with 1000 percent water content was injected. It was shown that the bentonite had a sealing effect but the depth of extrusion into rock joints was not large because of gelation. Electro-Kinetic injection of montmorillonite was found to be a more promising technique for rock lightening

  12. Anisomycin Injection in Area CA3 of the Hippocampus Impairs Both Short-Term and Long-Term Memories of Contextual Fear

    Science.gov (United States)

    Remaud, Jessica; Ceccom, Johnatan; Carponcy, Julien; Dugué, Laura; Menchon, Gregory; Pech, Stéphane; Halley, Helene; Francés, Bernard; Dahan, Lionel

    2014-01-01

    Protein synthesis is involved in the consolidation of short-term memory into long-term memory. Previous electrophysiological data concerning LTP in CA3 suggest that protein synthesis in that region might also be necessary for short-term memory. We tested this hypothesis by locally injecting the protein synthesis inhibitor anisomycin in hippocampal…

  13. Aboveground Injection Sytem Construction and Mecahnical Integrity Test Plan

    Energy Technology Data Exchange (ETDEWEB)

    Li, Jun [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-10-01

    An In-Situ Bioremediation (ISB) Pilot Test Treatability Study is planned at Sandia National Laboratories, New Mexico (SNL/NM) Technical Area-V (TA-V) Groundwater Area of Concern. The Treatability Study is designed to gravity inject an electron-donor substrate and bioaugmentation bacteria into groundwater using an injection well. The constituents of concern (COCs) are nitrate and trichloroethene (TCE). The Pilot Test Treatability Study will evaluate the effectiveness of bioremediation and COC treatment over a prescribed period of time. Results of the pilot test will provide data that will be used to evaluate the cost and effectiveness of a fullscale system.

  14. Diabetes Fear of Injecting and Self-Testing Questionnaire

    DEFF Research Database (Denmark)

    Mollema, E D; Snoek, Frank J; Pouwer, F

    2000-01-01

    OBJECTIVE: To study the psychometric properties of the Diabetes Fear of Injecting and Self-Testing Questionnaire (D-FISQ). RESEARCH DESIGN AND METHODS: Two groups of patients were studied. Sample A consisted of 252 insulin-treated diabetes patients. Sample B incorporated 24 insulin-treated patients......-injecting or self-testing had higher scores on FSI (P = 0.095) and FST (P = 0.01). EFA yielded 2 separate factors, FSI and FST. CONCLUSIONS: Results from this study support reliability and validity of the D-FISQ, a self-report instrument that can be used for both clinical and research purposes....

  15. Results of zinc injection test for Hamaoka Unit-1

    International Nuclear Information System (INIS)

    Kani, K.; Masuda, H.; Hayashi, Y.; Sudo, S.; Yamazaki, K.

    1998-01-01

    A zinc injection test was preformed at Hamaoka Nuclear Power Station Unit-1 for suppressing radiation dose rate on primary coolant recirculation piping after the replacement of piping. Zinc ion was injected by using injection system where Depleted Zinc Oxide was dissolved in carbonated water. Controllability of the system was sufficient to maintain concentration of zinc in primary water. The concentration of zinc in the primary coolant was controlled from 1 ppb to 5 ppb gradually. The increasing trend of concentration of Co-60 in the coolant was suppressed at zinc concentration of 3 ppb. It is evaluated that the deposition coefficient of Co-60 onto the surface of primary coolant recirculation piping was suppressed to one-third of previous cycle in average, and one-fourth of that just before injection start at zinc concentration of 5 ppb. We concluded that zinc injection is effective for suppressing dose rate on the primary coolant piping and no adverse effect occurs by zinc injection up to 5 ppb in the primary coolant. (J.P.N.)

  16. Simulation of the LHC injection kicker impedance test bench

    CERN Document Server

    Tsutsui, H

    2003-01-01

    The coupling impedance measurements of the LHC injection kicker test bench are simulated by HFSS code. The simulation gives qualitatively good agreement with the measurement. In order to damp the resonances, some ferrite rings are tested in the simulation. Longitudinal resonances are damped by a ferrite ring of large tan$\\delta_{\\mu}$. The effect of the ferrite ring is small for damping the transverse impedance resonance around 30 MHz.

  17. Long-term follow-up of high-pressure injection injuries to the hand

    NARCIS (Netherlands)

    Wieder, Anat; Lapid, Oren; Plakht, Ygal; Sagi, Amiram

    2006-01-01

    High-pressure injection injury is an injury caused by accidental injection of substances by industrial equipment. This injury may have devastating sequelae. The goal of this study was to assess the long-term outcome of high-pressure injection injury to the hand. In this historical prospective study,

  18. Experiment data report for Semiscale Mod-1 Test S-05-3 (alternate ECC injection test)

    International Nuclear Information System (INIS)

    Feldman, E.M.; Patton, M.L. Jr.; Sackett, K.E.

    1977-03-01

    Recorded test data are presented for Test S-05-3 of the Semiscale Mod-1 alternate ECC injection test series. These tests are among several Semiscale Mod-1 experiments conducted to investigate the thermal and hydraulic phenomena accompanying a hypothesized loss-of-coolant accident in a pressurized water reactor (PWR) system. Test S-05-3 was conducted from initial conditions of 2263 psia and 545 0 F to investigate the response of the Semiscale Mod-1 system to a depressurization and reflood transient following a simulated double-ended offset shear of the cold leg broken loop piping. During the test, cooling water was injected into the cold leg sides of the intact and broken loops and into the vessel upper plenum to simulate emergency core coolant injection in a PWR. For Test S-05-3, specifically the effects of upper plenum coolant injection on core thermal and system response were being investigated

  19. TRACKING TESTS FOR THE SNS FAST INJECTION BUMP POWER SUPPLY

    International Nuclear Information System (INIS)

    ENG, W.; CUTLER, R.; DEWAN, S.

    2004-01-01

    The tracking requirement of the SNS Fast Injection Bump power supplies is described. In addition to the usual tracking between the load current and the input reference of a power supply, these power supplies must also track between pairs of units under slightly different loads. This paper describes the use of a current-null test to measure tracking performances. For the actual tests, a single dummy magnet load was used to measure the tracking between the first two production units at the manufacturer's facility. Using the Yokogawa WE7000 waveform. PC-based measurement instrument, input and output waveforms are digitized and stored in data files. A program written for this application is then used to extract data from these files to construct, analyze the waveforms and characterize the power supply performance. Results of the measurements of two SNS Fast Injection Bump power supplies will be presented in this paper

  20. Experiment data report for Semiscale Mod-1 Test S-05-4 (alternate ECC injection test)

    International Nuclear Information System (INIS)

    Collins, B.L.; Feldman, E.M.

    1977-03-01

    Recorded test data are presented for Test S-05-4 of the Semiscale Mod-1 alternate emergency core coolant injection test series. These tests are among several Semiscale Mod-1 experiments conducted to investigate the thermal and hydraulic phenomena accompanying a hypothesized loss-of-coolant accident in a pressurized water reactor (PWR) system. Test S-05-4 was conducted from initial conditions of 2266 psia and 543 0 F to investigate the response of the Semiscale Mod-1 system to a depressurization and reflood transient following a simulated double-ended offset shear of the cold leg broken loop piping. During the test, cooling water was injected into the cold leg of each loop and into the vessel upper plenum to simulate emergency core coolant injection in a PWR. The upper plenum coolant injection was scaled according to the heat stored in the metal mass of the upper plenum

  1. Air injection test on a Kaplan turbine: prototype - model comparison

    Science.gov (United States)

    Angulo, M.; Rivetti, A.; Díaz, L.; Liscia, S.

    2016-11-01

    Air injection is a very well-known resource to reduce pressure pulsation magnitude in turbines, especially on Francis type. In the case of large Kaplan designs, even when not so usual, it could be a solution to mitigate vibrations arising when tip vortex cavitation phenomenon becomes erosive and induces structural vibrations. In order to study this alternative, aeration tests were performed on a Kaplan turbine at model and prototype scales. The research was focused on efficiency of different air flow rates injected in reducing vibrations, especially at the draft tube and the discharge ring and also in the efficiency drop magnitude. It was found that results on both scales presents the same trend in particular for vibration levels at the discharge ring. The efficiency drop was overestimated on model tests while on prototype were less than 0.2 % for all power output. On prototype, air has a beneficial effect in reducing pressure fluctuations up to 0.2 ‰ of air flow rate. On model high speed image computing helped to quantify the volume of tip vortex cavitation that is strongly correlated with the vibration level. The hydrophone measurements did not capture the cavitation intensity when air is injected, however on prototype, it was detected by a sonometer installed at the draft tube access gallery.

  2. Treatability Test Plan for 300 Area Uranium Stabilization through Polyphosphate Injection

    Energy Technology Data Exchange (ETDEWEB)

    Vermeul, Vincent R.; Williams, Mark D.; Fritz, Brad G.; Mackley, Rob D.; Mendoza, Donaldo P.; Newcomer, Darrell R.; Rockhold, Mark L.; Williams, Bruce A.; Wellman, Dawn M.

    2007-06-01

    The U.S. Department of Energy has initiated a study into possible options for stabilizing uranium at the 300 Area using polyphosphate injection. As part of this effort, PNNL will perform bench- and field-scale treatability testing designed to evaluate the efficacy of using polyphosphate injections to reduced uranium concentrations in the groundwater to meet drinking water standards (30 ug/L) in situ. This technology works by forming phosphate minerals (autunite and apatite) in the aquifer that directly sequester the existing aqueous uranium in autunite minerals and precipitates apatite minerals for sorption and long term treatment of uranium migrating into the treatment zone, thus reducing current and future aqueous uranium concentrations. Polyphosphate injection was selected for testing based on technology screening as part of the 300-FF-5 Phase III Feasibility Study for treatment of uranium in the 300-Area.

  3. Treatability Test Plan for 300 Area Uranium Stabilization through Polyphosphate Injection

    International Nuclear Information System (INIS)

    Vermeul, Vince R.; Williams, M. D.; Fritz, Brad G.; Mackley, Rob D.; Mendoza, Donaldo P.; Newcomer, Darrell R.; Rockhold, Mark L.; Williams, Bruce A.; Wellman, Dawn M.

    2007-01-01

    The U.S. Department of Energy has initiated a study into possible options for stabilizing uranium at the 300 Area using polyphosphate injection. As part of this effort, PNNL will perform bench- and field-scale treatability testing designed to evaluate the efficacy of using polyphosphate injections to reduced uranium concentrations in the groundwater to meet drinking water standards (30 (micro)g/L) in situ. This technology works by forming phosphate minerals (autunite and apatite) in the aquifer that directly sequester the existing aqueous uranium in autunite minerals and precipitates apatite minerals for sorption and long term treatment of uranium migrating into the treatment zone, thus reducing current and future aqueous uranium concentrations. Polyphosphate injection was selected for testing based on technology screening as part of the 300-FF-5 Phase III Feasibility Study for treatment of uranium in the 300-Area

  4. Automatic estimation of aquifer parameters using long-term water supply pumping and injection records

    Science.gov (United States)

    Luo, Ning; Illman, Walter A.

    2016-09-01

    Analyses are presented of long-term hydrographs perturbed by variable pumping/injection events in a confined aquifer at a municipal water-supply well field in the Region of Waterloo, Ontario (Canada). Such records are typically not considered for aquifer test analysis. Here, the water-level variations are fingerprinted to pumping/injection rate changes using the Theis model implemented in the WELLS code coupled with PEST. Analyses of these records yield a set of transmissivity ( T) and storativity ( S) estimates between each monitoring and production borehole. These individual estimates are found to poorly predict water-level variations at nearby monitoring boreholes not used in the calibration effort. On the other hand, the geometric means of the individual T and S estimates are similar to those obtained from previous pumping tests conducted at the same site and adequately predict water-level variations in other boreholes. The analyses reveal that long-term municipal water-level records are amenable to analyses using a simple analytical solution to estimate aquifer parameters. However, uniform parameters estimated with analytical solutions should be considered as first rough estimates. More accurate hydraulic parameters should be obtained by calibrating a three-dimensional numerical model that rigorously captures the complexities of the site with these data.

  5. Experiment data report for Semiscale Mod-1 Test S-05-1 (alternate ECC injection test)

    International Nuclear Information System (INIS)

    Feldman, E.M.; Patton, M.L. Jr.; Sackett, K.E.

    1977-02-01

    Recorded test data are presented for Test S-05-1 of the Semiscale Mod-1 alternate ECC injection test series. These tests are among several Semiscale Mod-1 experiments conducted to investigate the thermal and hydraulic phenomena accompanying a hypothesized loss-of-coolant accident in a pressurized water reactor (PWR) system. Test S-05-1 was conducted from initial conditions of 2263 psia and 544 0 F to investigate the response of the Semiscale Mod-1 system to a depressurization and reflood transient following a simulated double-ended offset shear of the cold leg broken loop piping. During the test, cooling water was injected into the vessel lower plenum to simulate emergency core coolant injection in a PWR, with the flow rate based on system volume scaling

  6. Experiment data report for Semiscale Mod-1 Test S-05-5 (alternate ECC injection test)

    International Nuclear Information System (INIS)

    Collins, B.L.; Patton, M.L. Jr.; Sackett, K.E.

    1977-04-01

    Recorded test data are presented for Test S-05-5 of the Semiscale Mod-1 alternate ECC injection test series. These tests are among several Semiscale Mod-1 experiments conducted to investigate the thermal and hydraulic phenomena accompanying a hypothesized loss-of-coolant accident in a pressurized water reactor (PWR) system. Test S-05-5 was conducted from initial conditions of 2263 psia and 537 0 F to investigate the response of the Semiscale Mod-1 system to a depressurization and reflood transient following a simulated double-ended offset shear of the cold leg broken loop piping. During the test, cooling water was injected into the cold leg of the intact and broken loops to simulate emergency core coolant injection in a PWR. The upper plenum was vented through a reflood bypass line interconnecting the hot and cold legs of the broken loop

  7. Stability study of methotrexate in 0.9% sodium chloride injection and 5% dextrose injection with limit tests for impurities

    DEFF Research Database (Denmark)

    Nissen, Klaus; Bogedal Jorgensen, Lene; Lindegaard Berg, Dorthe

    2017-01-01

    Purpose. Results of an evaluation of the stability of methotrexate in 0.9% sodium chloride injection and 5% dextrose injection are presented. Methods. Methotrexate concentrated solution (100 mg/mL) was diluted to nominal concentrations of 0.2 and 20 mg/mL in infusion bags containing 0.9% sodium...... chloride injection or 5% dextrose injection. The filled bags were stored for 28 days at 25 °C and 60% relative humidity and protected from light. Samples were withdrawn for analysis on the day of preparation and after 3, 7, 14, 21, and 28 days. The test program included visual inspections, measurements...... in amounts of known and unknown degradation products were detected. In 5% dextrose injection, methotrexate at the higher concentration was stable for 28 days, with minor formation of degradation products; in the 0.2-mg/mL solution, however, methotrexate was stable for only 3 days. At later time points...

  8. In Situ Decommissioning Sensor Network, Meso-Scale Test Bed - Phase 3 Fluid Injection Test Summary Report

    International Nuclear Information System (INIS)

    Serrato, M. G.

    2013-01-01

    The DOE Office of Environmental management (DOE EM) faces the challenge of decommissioning thousands of excess nuclear facilities, many of which are highly contaminated. A number of these excess facilities are massive and robust concrete structures that are suitable for isolating the contained contamination for hundreds of years, and a permanent decommissioning end state option for these facilities is in situ decommissioning (ISD). The ISD option is feasible for a limited, but meaningfull number of DOE contaminated facilities for which there is substantial incremental environmental, safety, and cost benefits versus alternate actions to demolish and excavate the entire facility and transport the rubble to a radioactive waste landfill. A general description of an ISD project encompasses an entombed facility; in some cases limited to the blow-grade portion of a facility. However, monitoring of the ISD structures is needed to demonstrate that the building retains its structural integrity and the contaminants remain entombed within the grout stabilization matrix. The DOE EM Office of Deactivation and Decommissioning and Facility Engineering (EM-13) Program Goal is to develop a monitoring system to demonstrate long-term performance of closed nuclear facilities using the ISD approach. The Savannah River National Laboratory (SRNL) has designed and implemented the In Situ Decommissioning Sensor Network, Meso-Scale Test Bed (ISDSN-MSTB) to address the feasibility of deploying a long-term monitoring system into an ISD closed nuclear facility. The ISDSN-MSTB goal is to demonstrate the feasibility of installing and operating a remote sensor network to assess cementitious material durability, moisture-fluid flow through the cementitious material, and resulting transport potential for contaminate mobility in a decommissioned closed nuclear facility. The original ISDSN-MSTB installation and remote sensor network operation was demonstrated in FY 2011-12 at the ISDSN-MSTB test cube

  9. In Situ Decommissioning Sensor Network, Meso-Scale Test Bed - Phase 3 Fluid Injection Test Summary Report

    Energy Technology Data Exchange (ETDEWEB)

    Serrato, M. G.

    2013-09-27

    The DOE Office of Environmental management (DOE EM) faces the challenge of decommissioning thousands of excess nuclear facilities, many of which are highly contaminated. A number of these excess facilities are massive and robust concrete structures that are suitable for isolating the contained contamination for hundreds of years, and a permanent decommissioning end state option for these facilities is in situ decommissioning (ISD). The ISD option is feasible for a limited, but meaningfull number of DOE contaminated facilities for which there is substantial incremental environmental, safety, and cost benefits versus alternate actions to demolish and excavate the entire facility and transport the rubble to a radioactive waste landfill. A general description of an ISD project encompasses an entombed facility; in some cases limited to the blow-grade portion of a facility. However, monitoring of the ISD structures is needed to demonstrate that the building retains its structural integrity and the contaminants remain entombed within the grout stabilization matrix. The DOE EM Office of Deactivation and Decommissioning and Facility Engineering (EM-13) Program Goal is to develop a monitoring system to demonstrate long-term performance of closed nuclear facilities using the ISD approach. The Savannah River National Laboratory (SRNL) has designed and implemented the In Situ Decommissioning Sensor Network, Meso-Scale Test Bed (ISDSN-MSTB) to address the feasibility of deploying a long-term monitoring system into an ISD closed nuclear facility. The ISDSN-MSTB goal is to demonstrate the feasibility of installing and operating a remote sensor network to assess cementitious material durability, moisture-fluid flow through the cementitious material, and resulting transport potential for contaminate mobility in a decommissioned closed nuclear facility. The original ISDSN-MSTB installation and remote sensor network operation was demonstrated in FY 2011-12 at the ISDSN-MSTB test cube

  10. Long-term persistence with injectable therapy in relapsing-remitting multiple sclerosis: an 18-year observational cohort study.

    Directory of Open Access Journals (Sweden)

    Simon Zhornitsky

    Full Text Available Disease modifying therapies (DMTs reduce the frequency of relapses and accumulation of disability in multiple sclerosis (MS. Long-term persistence with treatment is important to optimize treatment benefit. This long-term, cohort study was conducted at the Calgary MS Clinic. All consenting adults with relapsing-remitting MS who started either glatiramer acetate (GA or interferon-β 1a/1b (IFN-β between January 1st, 1996 and July 1st, 2011 were included. Follow-up continued to February 1st, 2014. Time-to-discontinuation of the initial and subsequently-prescribed DMTs (switches was analysed using Kaplan-Meier survival analyses. Group differences were compared using log-rank tests and multivariable Cox regression models. Analysis included 1471 participants; 906 were initially prescribed GA and 565 were initially prescribed IFN-β. Follow-up information was available for 87%; 29 (2% were lost to follow-up and 160 (11% moved from Southern Alberta while still using DMT. Median time-to-discontinuation of all injectable DMTs was 11.1 years. Participants with greater disability at treatment initiation, those who started treatment before age 30, and those who started between 2006 and 2011 were more likely to discontinue use of all injectable DMTs. Median time-to-discontinuation of the initial DMT was 8.6 years. Those initially prescribed GA remained on treatment longer. Of 610 participants who discontinued injectable DMT, 331 (54% started an oral DMT, or a second-line DMT, or resumed injectable DMT after 90 days. Persistence with injectable DMTs was high in this long-term population-based study. Most participants who discontinued injectable DMT did not remain untreated. Further research is required to understand treatment outcomes and outcomes after stopping DMT.

  11. Inadvertent injection of succinylcholine as an epidural test dose

    Directory of Open Access Journals (Sweden)

    Chryssa Pourzitaki

    Full Text Available Abstract Background and objectives: Epidural action of neuromuscular blocking agents could be explained under the light of their physicochemical characteristics and epidural space properties. In the literature there are few cases of accidental neuromuscular agent's epidural administration, manifesting mainly with neuromuscular blockade institution or fasciculations. Case report: We report a case of accidental succinylcholine administration as an epidural test dose, in a female patient undergoing scheduled laparotomy, under combined general and epidural anesthesia. Approximately 2 min after the succinylcholine injection the patient complained for shortness of breath, while mild fasciculations appeared in her trunk and face, managed by immediate general anesthesia institution. With the exception of a relatively longer duration of neuromuscular blockade compared with intravenous administration, no neurological or cardiovascular sequelae or other symptoms of local or systemic toxicity were observed. Conclusions: Oral administration of diazepam seems to lessen the adverse effects from accidental epidural administration of succinylcholine. The meticulous and discriminative labeling of syringes, as well as keeping persistent cautions during all anesthesia procedures remains of crucial importance.

  12. Control, data acquisition and analysis for the JET neutral injection test bed

    International Nuclear Information System (INIS)

    Jones, T.T.C.; Brenan, P.R.; Rodgers, M.E.; Stork, D.; Young, I.D.

    1984-01-01

    The Neutral Injection Test-Bed (NITB) is a major experimental assembly in support of the Neutral Beam Heating Programme for JET. In addition to its prime function of testing the Neutral Injection hardware, the Test Bed serves as the prototype to test the computer control and data acquisition system, which is described. (author)

  13. Laryngeal electromyography-guided hyaluronic acid vocal fold injection for unilateral vocal fold paralysis: a prospective long-term follow-up outcome report.

    Science.gov (United States)

    Wang, Chen-Chi; Chang, Ming-Hong; Jiang, Rong-San; Lai, Hsiu-Chin; De Virgilio, Armando; Wang, Ching-Ping; Wu, Shang-Heng; Liu, Shi-An; Liang, Kai-Li

    2015-03-01

    Unilateral vocal fold paralysis (UVFP) is a common voice disorder that may cause glottal closure insufficiency with hoarseness of voice. Laryngeal electromyography (LEMG)-guided hyaluronic acid vocal fold (VF) injection has been proposed as a treatment option to improve glottal closure with a satisfactory short-term effect. To our knowledge, this study reports the first long-term follow-up result of this treatment modality. To present the long-term treatment results of LEMG-guided hyaluronic acid VF injection for UVFP. Prospective study of the treatment results of 74 patients who received LEMG-guided hyaluronic acid VF injection for UVFP at a tertiary referral medical center from March 2010 to February 2013. In the office-based procedure, 1.0 mL of hyaluronic acid was injected via a 26-gauge monopolar injectable needle electrode into paralyzed thyroarytenoid muscles by LEMG guidance. Various glottal closure evaluations such as normalized glottal gap area, maximal phonation time, phonation quotient, mean airflow rate, perceptual GRBAS (grade, roughness, breathiness, asthenia, strain) scale, and Voice Handicap Index were compared before and after injection using the nonparametric Wilcoxon signed rank test within 1 month, at 6 months, and at the last follow-up examination. Sixty patients had been followed up for at least 6 months. Forty-four patients received only 1 injection, and 16 patients received repeated injections (2 injections for 13 patients and 3 for 3 patients). All the glottal closure parameters improved significantly (P injection and 16 (22%) who received repeated injections did not require another treatment after long-term follow-up. Laryngeal electromyography-guided hyaluronic acid VF injection is an option for treating UVFP with satisfactory results.

  14. The impact of interpreted flow regimes during constant head injection tests on the estimated transmissivity from injection tests and difference flow logging

    Energy Technology Data Exchange (ETDEWEB)

    Hjerne, Calle; Ludvigsson, Jan-Erik; Harrstroem, Johan [Geosigma AB, Uppsala (Sweden)

    2013-04-15

    A large number of constant head injection tests were carried out in the site investigation at Forsmark using the Pipe String System, PSS3. During the original evaluation of the tests the dominating transient flow regimes during both the injection and recovery period were interpreted together with estimation of hydraulic parameters. The flow regimes represent different flow and boundary conditions during the tests. Different boreholes or borehole intervals may display different distributions of flow regimes. In some boreholes good agreement was obtained between the results of the injection tests and difference flow logging with Posiva flow log (PFL) but in other boreholes significant discrepancies were found. The main objective of this project is to study the correlation between transient flow regimes from the injection tests and other borehole features such as transmissivity, depth, geology, fracturing etc. Another subject studied is whether observed discrepancies between estimated transmissivity from difference flow logging and injection tests can be correlated to interpreted flow regimes. Finally, a detailed comparison between transient and stationary evaluation of transmissivity from the injection tests in relation to estimated transmissivity from PFL tests in corresponding sections is made. Results from previous injection tests in 5 m sections in boreholes KFM04, KFM08A and KFM10A were used. Only injection tests above the (test-specific) measurement limit regarding flow rate are included in the analyses. For all of these tests transient flow regimes were interpreted. In addition, results from difference flow logging in the corresponding 5 m test sections were used. Finally, geological data of fractures together with rock and fracture zone properties have been used in the correlations. Flow regimes interpreted from the injection period of the tests are generally used in the correlations but deviations between the interpreted flow regimes from the injection and

  15. Short-term outcome of fluoroscopic-guided steroid injection therapy of lumber facet cyst-induced radicular pain

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Mi Ri; Kwon, Jong Won; Lee, Jong Seo; Kim, Eu Sang [Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2015-04-15

    To determine the short-term effect of fluoroscopic-guided steroid injection therapy of lumbar facet cyst-induced radicular pain. Seventeen patients with radiculopathy due to lumbar synovial cysts, who were treated with fluoroscopically guided injection, were retrospectively evaluated. All plain radiographic images and MR images before the therapy were reviewed. Five patients underwent only the facet joint injection, whereas twelve patients underwent the facet joint injection with perineural injection therapy. The clinical course of pain was evaluated on the first follow-up after therapy. Effective pain relief was achieved in 11 (64.7%) of the 17 patients. Among 12 patients who underwent facet joint injection with perineural injection, 9 patients (75%) had an effective pain relief. Of 5 patients, 2 (40%) patients only took the facet joint injection and had an effective pain relief. Fluoroscopic-guided steroid injection therapy shows a good short-term effect in patients with symptomatic lumbar facet joint synovial cysts.

  16. Fluoroscopically Guided Sacroiliac Joint Injections: Comparison of the Effects of Intraarticular and Periarticular Injections on Immediate and Short-Term Pain Relief.

    Science.gov (United States)

    Nacey, Nicholas C; Patrie, James T; Fox, Michael G

    2016-11-01

    The purpose of this study was to determine whether intraarticular sacroiliac joint injections provide greater immediate and short-term pain relief than periarticular sacroiliac joint injections do. The records of all fluoroscopically guided sacroiliac joint injections performed over a 4-year period were identified. Patients who received an injection of 0.5 mL of bupivacaine and 0.5 mL (20 mg) of triamcinolone and who had preinjection, immediate, and 1-week postinjection pain scores (0-10 numeric scale) were included. Images from the procedures were retrospectively reviewed by two musculoskeletal radiologists to determine intraarticular or periarticular administration of the injection with discrepancies resolved by consensus. One hundred thirteen injections in 99 patients (65 women, 34 men; mean age, 59.4 years) met the inclusion criteria. There were 55 intraarticular and 58 periarticular injections. The mean preinjection, immediate, and 1-week postinjection pain scores for the intraarticular injections were 6.0, 1.6, and 4.1 and for the periarticular injections were 6.1, 2.0, and 4.2. The mean immediate and 1-week postinjection pain reduction were statistically significant in both groups (p sacroiliac joint injections provide statistically significant immediate and 1-week postinjection pain relief, no significant difference in the degree of pain relief achieved with intraarticular and periarticular injections was noted.

  17. Short-term outcome after intravitreal ranibizumab injections for the treatment of retinopathy of prematurity.

    Science.gov (United States)

    Castellanos, María Ana Martínez; Schwartz, Shulamit; García-Aguirre, Gerardo; Quiroz-Mercado, Hugo

    2013-07-01

    To evaluate ocular outcome in premature infants treated with intravitreal ranibizumab injections for retinopathy of prematurity (ROP) over a period of 3 years. An interventional case series. Premature infants with high-risk prethreshold or threshold ROP with plus disease received an off label monotherapy with intravitreal injections of ranibizumab. The primary outcome was treatment success defined as regression of neovascularisation (NV) and absence of recurrence. The secondary outcomes were ocular and systemic adverse events and visual acuity. Six eyes were included in the study and treated with intravitreal injections of ranibizumab. All showed complete resolution of NV after a single injection. The anti-angiogenic intravitreal injections allowed for continued normal vessel growth into the peripheral retina, without any signs of disease recurrence or progression during the follow up period. No ocular or systemic adverse effects were observed. Three years of follow up in a small series suggest that intravitreal ranibizumab injections for ROP result in apparently preserved ocular outcome. Further large scale studies are needed to address the long-term safety and efficacy.

  18. Jet flow analysis of liquid poison injection in a CANDU reactor using source term

    International Nuclear Information System (INIS)

    Chae, Kyung Myung; Choi, Hang Bok; Rhee, Bo Wook

    2001-01-01

    For the performance analysis of Canadian deuterium uranium (CANDU) reactor shutdown system number 2 (SDS2), a computational fluid dynamics model of poison jet flow has been developed to estimate the flow field and poison concentration formed inside the CANDU reactor calandria. As the ratio of calandria shell radius over injection nozzle hole diameter is so large (1055), it is impractical to develop a full-size model encompassing the whole calandria shell. In order to reduce the model to a manageable size, a quarter of one-pitch length segment of the shell was modeled using symmetric nature of the jet; and the injected jet was treated as a source term to avoid the modeling difficulty caused by the big difference of the hole sizes. For the analysis of an actual CANDU-6 SDS2 poison injection, the grid structure was determined based on the results of two-dimensional real- and source-jet simulations. The maximum injection velocity of the liquid poison is 27.8 m/s and the mass fraction of the poison is 8000 ppm (mg/kg). The simulation results have shown well-established jet flow field. In general, the jet develops narrowly at first but stretches rapidly. Then, the flow recirculates a little in r-x plane, while it recirculates largely in r-θ plane. As the time goes on, the adjacent jets contact each other and form a wavy front such that the whole jet develops in a plate form. his study has shown that the source term model can be effectively used for the analysis of the poison injection and the simulation result of the CANDU reactor is consistent with the model currently being used for the safety analysis. In the future, it is strongly recommended to analyze the transient (from helium tank to injection nozzle hole) of the poison injection by applying Bernoulli equation with real boundary conditions

  19. Experiment data report for Semiscale Mod-1 Test S-05-2 (alternate ECC injection test)

    International Nuclear Information System (INIS)

    Feldman, E.M.; Collins, B.L.; Sackett, K.E.

    1977-02-01

    Recorded test data are presented for Test S-05-2 of the Semiscale Mod-1 alternate emergency core coolant (ECC) injection test series. This test is one of several Semiscale Mod-1 experiments conducted to investigate the thermal and hydraulic phenomena accompanying a hypothesized loss-of-coolant accident in a pressurized water reactor (PWR) system. Test S-05-2 was conducted from an initial cold leg fluid temperature of 545 0 F and an initial pressure of 2263 psia. A simulated double-ended offset shear cold leg break was used to investigate core and system response to a depressurization and reflood transient with ECC injection at the intact loop pump suction and broken loop cold leg. A reduced lower plenum volume was used for this test to more accurately represent the lower plenum of a PWR, based on system volume scaling. System flow was set to achieve a core fluid temperature differential of 65 0 F at a core power level of 1.44 MW. The flow resistance of the intact loop was based on core area scaling. An electrically heated core with a slightly peaked radial power profile was used in the pressure vessel to simulate the predicted surface heat flux of nuclear fuel rods during a loss-of-coolant accident

  20. Long-term follow-up after urethral injection with polyacrylamide hydrogel for female stress incontinence

    DEFF Research Database (Denmark)

    Mouritsen, Lone; Lose, Gunnar; Møller-Bek, Karl

    2014-01-01

    Urethral injection therapy for treatment of stress urinary incontinence has been in use for years, but only a few long-term follow-up studies have been published. Twenty-five women, injected with polyacrylamide hydrogel 8 years earlier, were invited for follow-up. Twenty-four could be contacted; 15...... had had no further treatment, seven had been re-operated with placement of mid-urethral slings, and two had been re-injected with polyacrylamide hydrogel. Eleven women attended for objective examination; all non-attenders were interviewed by telephone. Subjectively, in 44% the stress incontinence...... was cured or much improved, with a positive outcome according to the King's Health Questionnaire. Objectively, all patients had visible polyacrylamide hydrogel deposits on vaginal ultrasonography. No local adverse reactions were seen in the vaginal mucosa. The results of a later mid-urethral sling were...

  1. Injection molded nanofluidic chips: Fabrication method and functional tests using single-molecule DNA experiments

    DEFF Research Database (Denmark)

    Utko, Pawel; Persson, Karl Fredrik; Kristensen, Anders

    2011-01-01

    We demonstrate that fabrication of nanofluidic systems can be greatly simplified by injection molding of polymers. We functionally test our devices by single-molecule DNA experiments in nanochannels.......We demonstrate that fabrication of nanofluidic systems can be greatly simplified by injection molding of polymers. We functionally test our devices by single-molecule DNA experiments in nanochannels....

  2. Fluoroscopically guided caudal epidural steroid injection for management of degenerative lumbar spinal stenosis: short-term and long-term results

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Joon Woo; Myung, Jae Sung; Kang, Heung Sik [Seoul National University Bundang Hospital, Department of Radiology, Seong Nam, Gyeongi-do (Korea); Park, Kun Woo; Yeom, Jin S. [Seoul National University Bundang Hospital, Department of Orthopaedic Surgery, Seong Nam, Gyeongi-do (Korea); Kim, Ki-Jeong; Kim, Hyun-Jib [Seoul National University Bundang Hospital, Department of Neurosurgery, Seong Nam, Gyeongi-do (Korea)

    2010-07-15

    To evaluate the short-term and long-term effects of fluoroscopically guided caudal epidural steroid injection (ESI) for the management of degenerative lumbar spinal stenosis (DLSS) and to analyze outcome predictors. All patients who underwent caudal ESI in 2006 for DLSS were included in the study. Response was based on chart documentation (aggravated, no change, slightly improved, much improved, no pain). In June 2009 telephone interviews were conducted, using formatted questions including the North American Spine Society (NASS) patient satisfaction scale. For short-term and long-term effects, age difference was evaluated by the Mann-Whitney U test, and gender, duration of symptoms, level of DLSS, spondylolisthesis, and previous operations were evaluated by Fisher's exact test. Two hundred and sixteen patients (male: female = 75:141; mean age 69.2 years; range 48{proportional_to}91 years) were included in the study. Improvements (slightly improved, much improved, no pain) were seen in 185 patients (85.6%) after an initial caudal ESI and in 189 patients (87.5%) after a series of caudal ESIs. Half of the patients (89/179, 49.8%) replied positively to the NASS patient satisfaction scale (1 or 2). There were no significant outcome predictors for either the short-term or the long-term responses. Fluoroscopically guided caudal ESI was effective for the management of DLSS (especially central canal stenosis) with excellent short-term and good long-term results, without significant outcome predictors. (orig.)

  3. Intrathecal injection of naked plasmid DNA provides long-term expression of secreted proteins.

    Science.gov (United States)

    Hughes, Travis S; Langer, Stephen J; Johnson, Kirk W; Chavez, Raymond A; Watkins, Linda R; Milligan, Erin D; Leinwand, Leslie A

    2009-01-01

    Therapeutic benefit has been reported to result from intrathecal (i.t.) injection of transgene vectors, including naked DNA. However, most studies using naked DNA have measured only the transgene expression of intracellular proteins. Here we demonstrate that i.t. injection of naked DNA can result in long-term expression of secreted proteins. Plasmids expressing either secreted alkaline phosphatase (SEAP) or human interleukin-10 (hIL-10) were injected into the i.t. space in rats, and transgene products were repeatedly measured in the cerebrospinal fluid (CSF). Both SEAP and hIL-10 were maximal at 1 and 2 days after the injection and still detectable at 4 months. The utilization of a plasmid having two features that are hypothesized to increase gene expression (matrix attachment regions (MARs) and lack of CpG dinucleotides) resulted in a significant increase in gene expression. Reinjection of SEAP or hIL-10 plasmids after 4 months significantly increased protein levels at 1 and 14 days after the reinjection. SEAP was uniformly distributed between the DNA delivery site (approximately vertebral level T13) and the lumbar puncture site (L5/L6 inter-vertebral space), was reduced at the cisterna magna, and was detectable, though at much lower levels, in serum. These data suggest that naked DNA has the potential to be used as a therapeutic tool for applications that require long-term release of transgenes into the CSF.

  4. Long-term CO2 injection and its impact on near-surface soil microbiology.

    Science.gov (United States)

    Gwosdz, Simone; West, Julia M; Jones, David; Rakoczy, Jana; Green, Kay; Barlow, Tom; Blöthe, Marco; Smith, Karon; Steven, Michael; Krüger, Martin

    2016-12-01

    Impacts of long-term CO 2 exposure on environmental processes and microbial populations of near-surface soils are poorly understood. This near-surface long-term CO 2 injection study demonstrated that soil microbiology and geochemistry is influenced more by seasonal parameters than elevated CO 2 Soil samples were taken during a 3-year field experiment including sampling campaigns before, during and after 24 months of continuous CO 2 injection. CO 2 concentrations within CO 2 -injected plots increased up to 23% during the injection period. No CO 2 impacts on geochemistry were detected over time. In addition, CO 2 -exposed samples did not show significant changes in microbial CO 2 and CH 4 turnover rates compared to reference samples. Likewise, no significant CO 2 -induced variations were detected for the abundance of Bacteria, Archaea (16S rDNA) and gene copy numbers of the mcrA gene, Crenarchaeota and amoA gene. The majority (75%-95%) of the bacterial sequences were assigned to five phyla: Firmicutes, Proteobacteria, Actinobacteria, Acidobacteria and Bacteroidetes The majority of the archaeal sequences (85%-100%) were assigned to the thaumarchaeotal cluster I.1b (soil group). Univariate and multivariate statistical as well as principal component analyses showed no significant CO 2 -induced variation. Instead, seasonal impacts especially temperature and precipitation were detected. © FEMS 2016. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  5. Short-term muscle atrophy caused by botulinum toxin-A local injection impairs fracture healing in the rat femur.

    Science.gov (United States)

    Hao, Yongqiang; Ma, Yongcheng; Wang, Xuepeng; Jin, Fangchun; Ge, Shengfang

    2012-04-01

    Damaged bone is sensitive to mechanical stimulation throughout the remodeling phase of bone healing. Muscle damage and muscular atrophy associated with open fractures and subsequent fixation are not beneficial to maintaining optimum conditions for mechanical stability. The aim of this study was to investigate whether local muscle atrophy and dysfunction affect fracture healing in a rat femur fracture model. We combined the rat model of a short period atrophy of the quadriceps with femur fracture. Forty-four-month-old male Wistar rats were adopted for this study. Two units of botulinum toxin-A (BXTA) were administered locally into the right side of the quadriceps of each rat, while the same dose of saline was injected into the contralateral quadriceps. After BXTA had been fully absorbed by the quadriceps, osteotomy was performed in both femurs with intramedullary fixation. Gross observation and weighing of muscle tissue, X-ray analysis, callus histology, and bone biomechanical testing were performed at different time points up to 8 weeks post-surgery. Local injection of BXTA led to a significant decrease in the volume and weight of the quadriceps compared to the control side. At the eighth week, the left side femurs of the saline-injected quadriceps almost reached bony union, and fibrous calluses were completely calcified into woven bone. However, a gap was still visible in the BXTA-treated side on X-ray images. As showed by bone histology, there were no mature osseous calluses or woven bone on the BXTA-treated side, but a resorption pattern was evident. Biomechanical testing indicated that the femurs of the BXTA-treated side exhibited inferior mechanical properties compared with the control side. The inferior outcome following BXTA injection, compared with saline injection, in terms of callus resistance may be the consequence of unexpected load and mechanical unsteadiness caused by muscle atrophy and dysfunction. Copyright © 2011 Orthopaedic Research Society.

  6. Control, data acquisition and analysis for the JET neutral injection test bed

    International Nuclear Information System (INIS)

    Jones, T.T.C.; Brenan, P.R.; Rodgers, M.E.; Stork, D.; Young, I.D.

    1985-01-01

    The Neutral Injection Test-Bed (NITB) is a major experimental assembly in support of the Neutral Beam Heating Programme for JET. In addition to its prime function of testing the Neutral Injection hardware, the Test Bed serves as the prototype to test the computer control and data acquisition system, which is described in this paper. The software system has been written in a portable, data-driven manner with the aim to adapt it, with only minor modifications to the operation of the first. Neutral Injection Beamline on JET, which will involve operation both synchronous and asynchronous with that of the JET Tokamak

  7. Riboflavin laurate nanosuspensions as an intramuscular injection for long-term riboflavin supplementation.

    Science.gov (United States)

    Du, Lina; Li, Guanglong; Jin, Yiguang; Wang, Lin; Xu, Qishou; Dong, Junxing

    2013-06-25

    The aim of this study was to prepare riboflavin laurate (RFL) nanosuspensions as an intramuscular injection for long-term riboflavin supplementation. Stable RFL nanosuspensions were obtained by injecting RFL/poloxamer solution in N,N-dimethyl formamide into a trehalose solution. Long soft nanostructures initially appeared and then tube-like rigid nanostructures were obtained after removal of solvents according to the transmission electron microscopic images. The nanosuspensions had narrow size distribution and the mean size was about 300 nm. Molecular self-assembly of RFL may drive the formation of nanostructures. RFL formed a monolayer at the air/water interface and poloxamer 188 could insert into the monolayer. The nanosuspensions were intramuscularly injected into rats to provide long-term riboflavin supplementation for more than 30 days in light of body weight, food intake, and urinary riboflavin. The nanosuspensions were also used to resist the riboflavin deficiency induced by methotrexate chemotherapy. RFL nanosuspensions are a promising nanomedicine for long-term riboflavin supplementation. Copyright © 2013 Elsevier B.V. All rights reserved.

  8. Long term testing of PSI-membranes

    Energy Technology Data Exchange (ETDEWEB)

    Huslage, J; Brack, H P; Geiger, F; Buechi, F N; Tsukada, A; Scherer, G G [Paul Scherrer Inst. (PSI), Villigen (Switzerland)

    1999-08-01

    Long term tests of PSI membranes based on radiation-grafted FEP and ETFE films were carried out and FEP-based membranes were evaluated by monitoring the in-situ membrane area resistance measured by a current pulse method. By modifying our irradiation procedure and using the double crosslinking concept we obtain reproducible membrane cell lifetimes (in term of in-situ membrane resistance) of greater than 5000 hours at 60-65{sup o}C. Preliminary tests at 80-85{sup o}C with lifetimes of greater than 2500 demonstrate the potential long term stability of PSI proton exchange membranes based on FEP over the whole operating temperature range of low-temperature polymer electrolyte fuel cells. Radiation grafted PSI membranes based on ETFE have better mechanical properties than those of the FEP membranes. Mechanical properties are particularly important in large area cells and fuel cell stacks. ETFE membranes have been tested successfully for approximately 1000 h in a 2-cell stack (100 cm{sup 2} active area each cell). (author) 4 figs., 4 refs.

  9. Shortlasting Unilateral Neuralgiform Conjunctival Injection and Tearing Syndrome: The Term and New View Points

    Science.gov (United States)

    Antonaci, Fabio; Fredriksen, Torbjørn; Pareja, Juan A.; Sjaastad, Ottar

    2018-01-01

    A solitary patient with symptoms similar to those of shortlasting unilateral neuralgiform conjunctival injection and tearing (SUNCT) was first mentioned in 1978. The term SUNCT was first used in 1991. SUNCT is an acronym; the “S” signifies “Shortlasting”; the “U” symbolizes “Unilateral”; “N” stands for “Neuralgiform”; the “C” for “Conjunctival injection”; and “T” for “Tearing.” The term short-lasting unilateral neuralgiform headache attacks with cranial autonomic symptoms were marketed in 2004. The terminology and new view points are discussed and nosography proposal for SUNCT is presented. PMID:29740387

  10. Additional short-term plutonium urinary excretion data from the 1945-1947 plutonium injection studies

    International Nuclear Information System (INIS)

    Moss, W.D.; Gautier, M.A.

    1985-01-01

    A review of original injection experimental records at LASL suggest that the power function fit is a good choice to describe early plutonium excretion; however, the later period (300-, 500-, and 1600-day) results along with 10,000 day results show a significant departure from the Langham power function model used to describe long-term Pu excretion. The authors suggest that since the 523- and 1600-day data in question influenced the mathematical development of the Langham power function equation, its use in predicting Pu body burdens from long-term excretion data should be discouraged. 9 references, 2 figures, 2 tables

  11. Short-term intraocular pressure changes after intravitreal injection of bevacizumab in diabetic retinopathy patients

    Directory of Open Access Journals (Sweden)

    Farhood QK

    2014-03-01

    Full Text Available Qasim Kadhim Farhood,1 Sinan Mohammad Twfeeq21College of Medicine, Babylon University, Babylon; 2Al-Jumhori teaching hospital, Mosul, IraqBackground: This study examined the changes in short-term intraocular pressure (IOP in a prospective series of patients undergoing intravitreal bevacizumab injection. The aim was to evaluate the frequency and predictive factors related to intraocular pressure (IOP elevation in patients receiving intravitreal bevacizumab.Patients and methods: This study included 52 patients with diabetic retinopathy between 28 to 75 years of age with a mean age of 51 years; 30 (58% were females, and 22 (42% were males. All patients received bevacizumab (1.25 mg/0.05 mL injected intravitreally in a standard fashion between May 2012 to February 2013 in the AL-Jumhoury teaching hospital. IOP was measured at baseline, 5, 10, and 30 minutes after injection using Goldman applanation tonometry.Statistics: Data were analyzed using the SPSS v.12.0 for windows. Basic, demographic, and clinical data were analyzed using means, proportions, and appropriate 95% confidence intervals (CIs.Results: Most patients (85% were diagnosed with proliferative diabetic retinopathy, while 15% presented with diabetic macular edema. The mean IOP values at baseline, 5, 10, and 30 minutes after injection were 14.0 mmHg (95% CI 13.4–14.7, 36.1 mmHg (95% CI 33.5–38.6, 25.7 mmHg (95% CI 23.8–27.5, and 15.5 mmHg (95% CI 12.4–16.51, respectively. Regression analysis showed a trend toward phakic patients having higher IOP at 30 minutes.Conclusion: Intravitreal injection of bevacizumab is safe with respect to short-term IOP changes, as almost all IOP returned to a safe range (<25 mmHg within 30 minutes. Elevated IOP 30 minutes after injection only occurs rarely, so routine prophylactic use of anti-glaucoma medication is not indicated.Keywords: intravitreal injection, bevacizumab, intraocular pressure, Goldmann applanation tonometry

  12. Polydimethylsiloxane Injection Laryngoplasty for Unilateral Vocal Fold Paralysis: Long-Term Results.

    Science.gov (United States)

    Mattioli, Francesco; Bettini, Margherita; Botti, Cecilia; Busi, Giulia; Tassi, Sauro; Malagoli, Andrea; Molteni, Gabriele; Trebbi, Marco; Luppi, Maria Pia; Bergamini, Giuseppe; Presutti, Livio

    2017-07-01

    To analyze the long-term objective, perceptive, and subjective outcomes after endoscopic polydimethylsiloxane (PDMS) injection laryngoplasty in unilateral vocal fold paralysis. A retrospective study carried out between January 2008 and January 2012. Head and Neck Department, University Hospital of Modena, Modena, Italy. This was a retrospective analysis of 26 patients with unilateral vocal fold paralysis who underwent endoscopic injection of PDMS under general anesthesia. A voice evaluation protocol was performed for all patients, which included videolaryngostroboscopy, maximum phonation time, fundamental frequency, analysis of the harmonic structure of the vowel /a/ and the word /aiuole/, Grade of Dysphonia, Instability, Roughness, Breathiness, Asthenia, and Strain scale, and Voice Handicap Index. The protocol was performed before surgery, in the immediate postoperative period, and at least 3 years after surgery. The mean follow-up period was 73 months (range 39-119 months). The statistical analysis showed a significant improvement (P injection laryngoplasty with PDMS guarantees long-lasting effects over time. No complications were reported in our series. Injection laryngoplasty with PDMS can be considered to be a minimally invasive and safe technique for the treatment of unilateral vocal fold paralysis. Moreover, it allows very good and stable results to be obtained over time, avoiding repeated treatments and improving the quality of life of the patients. Copyright © 2017 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  13. Irreversible muscle damage in bodybuilding due to long-term intramuscular oil injection.

    Science.gov (United States)

    Banke, I J; Prodinger, P M; Waldt, S; Weirich, G; Holzapfel, B M; Gradinger, R; Rechl, H

    2012-10-01

    Intramuscular oil injections generating slowly degrading oil-based depots represent a controversial subject in bodybuilding and fitness. However they seem to be commonly reported in a large number of non-medical reports, movies and application protocols for 'site-injections'. Surprisingly the impact of long-term (ab)use on the musculature as well as potential side-effects compromising health and sports ability are lacking in the medical literature. We present the case of a 40 year old male semi-professional bodybuilder with systemic infection and painful reddened swellings of the right upper arm forcing him to discontinue weightlifting. Over the last 8 years he daily self-injected sterilized sesame seed oil at numerous intramuscular locations for the purpose of massive muscle building. Whole body MRI showed more than 100 intramuscular rather than subcutaneous oil cysts and loss of normal muscle anatomy. 2-step septic surgery of the right upper arm revealed pus-filled cystic scar tissue with the near-complete absence of normal muscle. MRI 1 year later revealed the absence of relevant muscle regeneration. Persistent pain and inability to perform normal weight training were evident for at least 3 years post-surgery. This alarming finding indicating irreversible muscle mutilation may hopefully discourage people interested in bodybuilding and fitness from oil-injections. The impact of such chronic tissue stress on other diseases like malignancy remains to be determined. © Georg Thieme Verlag KG Stuttgart · New York.

  14. Pilot test of pressure maintenance by water injection and gas injection in the M'Bega field

    Energy Technology Data Exchange (ETDEWEB)

    Hodee, B

    1965-02-01

    The M'Bega reservoir, Gabon, is one that is both fractured and fissured, and its reservoir rock, improperly referred to as silicified clay, is made up of opal-cement silt. At the time it began production, the major unknown factor in this field was the amount of oil it contained. The factor was finally determined after 18 mo. of production, once data was obtained concerning the advance of aquifiers. Up until that time, applied comparisons of successive data could not differentiate between the activity of aquifers and that of dissolved gas expansion with partial segregation. Consequently, a pilot test was made in which pressure was maintained by water injection. Then, with a double drainage phenomena (the tops by the gas, and the flanks by the aquifer water), production of the field consisted of bringing about a coincidence between the water and gas fronts at the level of the existing wells by means of gas injection.

  15. Injection-induced gluteus muscle contractures: diagnosis with the "reverse Ober test" and surgical management.

    Science.gov (United States)

    Scully, William F; White, Klane K; Song, Kit M; Mosca, Vincent S

    2015-03-01

    Adoption rates are increasing in the United States and other developed countries. A large proportion of adopted children have been found to have unsuspected medical diagnoses, including orthopedic problems. One condition, termed injection-induced gluteus maximus contracture, has been previously described in several case series and can be difficult to diagnose if unfamiliar with this condition. By reviewing the etiology and pathoanatomy of this problem, as well as the typical examination findings, including the near-pathognomonic-positive "reverse Ober test," treating providers will be better prepared to recognize and properly treat this condition. This is a retrospective review of 4 patients treated at our institution for injection-induced gluteus maximus contracture. Patient history, physical examination findings, and treatment outcomes were recorded. All had undergone surgical treatment through a longitudinal incision along the posterior margin of the iliotibial band, with division of thickened, contracted gluteus tissue down to the ischial tuberosity. All 4 of the patients were adopted from orphanages in developing countries. Chief complaints of the patients varied, but physical examination findings were very consistent. Three of the 4 patients had undergone rotational osteotomies for presumed femoral retroversion before their diagnosis and treatment for injection-induced gluteus maximus contracture. All patients had concave, atrophic buttock contours and numerous punctate buttock scars. All walked with an out-toed gait and had marked apparent femoral retroversion. Each patient was found to have full hip adduction when the hip was extended but a hip abduction contracture when the hip was flexed. This finding of increasing abduction as an extended/adducted hip is flexed to 90 degrees is described as a positive "reverse Ober test." After surgical treatment, all hips could adduct to neutral from full extension to full flexion. Although common in some countries

  16. Field Testing of Activated Carbon Injection Options for Mercury Control at TXU's Big Brown Station

    Energy Technology Data Exchange (ETDEWEB)

    John Pavlish; Jeffrey Thompson; Christopher Martin; Mark Musich; Lucinda Hamre

    2009-01-07

    The primary objective of the project was to evaluate the long-term feasibility of using activated carbon injection (ACI) options to effectively reduce mercury emissions from Texas electric generation plants in which a blend of lignite and subbituminous coal is fired. Field testing of ACI options was performed on one-quarter of Unit 2 at TXU's Big Brown Steam Electric Station. Unit 2 has a design output of 600 MW and burns a blend of 70% Texas Gulf Coast lignite and 30% subbituminous Powder River Basin coal. Big Brown employs a COHPAC configuration, i.e., high air-to-cloth baghouses following cold-side electrostatic precipitators (ESPs), for particulate control. When sorbent injection is added between the ESP and the baghouse, the combined technology is referred to as TOXECON{trademark} and is patented by the Electric Power Research Institute in the United States. Key benefits of the TOXECON configuration include better mass transfer characteristics of a fabric filter compared to an ESP for mercury capture and contamination of only a small percentage of the fly ash with AC. The field testing consisted of a baseline sampling period, a parametric screening of three sorbent injection options, and a month long test with a single mercury control technology. During the baseline sampling, native mercury removal was observed to be less than 10%. Parametric testing was conducted for three sorbent injection options: injection of standard AC alone; injection of an EERC sorbent enhancement additive, SEA4, with ACI; and injection of an EERC enhanced AC. Injection rates were determined for all of the options to achieve the minimum target of 55% mercury removal as well as for higher removals approaching 90%. Some of the higher injection rates were not sustainable because of increased differential pressure across the test baghouse module. After completion of the parametric testing, a month long test was conducted using the enhanced AC at a nominal rate of 1.5 lb/Macf. During

  17. Long-term continuous energy injection in the afterglow of GRB 060729

    International Nuclear Information System (INIS)

    Xu Ming; Huang Yongfeng; Lu Tan

    2009-01-01

    A long plateau phase and an amazing level of brightness have been observed in the X-ray afterglow of GRB 060729. This peculiar light curve is likely due to long-term energy injection in external shock. Here, we present a detailed numerical study of the energy injection process of magnetic dipole radiation from a strongly magnetized millisecond pulsar and model the multi-band afterglow observations. It is found that this model can successfully explain the long plateaus in the observed X-ray and optical afterglow light curves. The sharp break following the plateaus could be due to the rapid decline of the emission power of the central pulsar. At an even later time (∼ 5 x 10 6 s), an obvious jet break appears, which implies a relatively large half opening angle of θ ∼ 0.3 for the GRB ejecta. Due to the energy injection, the Lorentz factor of the outflow is still larger than two even at 10 7 s after the GRB trigger, making the X-ray afterglow of this burst detectable by Chandra even 642 d after the burst.

  18. Tokamak Fusion Test Reactor neutral beam injection system vacuum chamber

    International Nuclear Information System (INIS)

    Pedrotti, L.R.

    1977-01-01

    Most of the components of the Neutral Beam Lines of the Tokamak Fusion Test Reactor (TFTR) will be enclosed in a 50 cubic meter box-shaped vacuum chamber. The chamber will have a number of unorthodox features to accomodate both neutral beam and TFTR requirements. The design constraints, and the resulting chamber design, are presented

  19. A test to prevent subarachnoid and intravascular injections during ...

    African Journals Online (AJOL)

    The test involves 3 steps after removal of the filter: (i) the open end of the epidural catheter is lifted and the liquid meniscus present in the catheter is observed to drop rapidly; (H) the open end of the epidural catheter is lowered and the liquid meniscus is again observed to fill the catheter with clear liquid and no blood; (iii) the ...

  20. Test of safety injection supply by diesel generator under reactor vessel closed condition

    International Nuclear Information System (INIS)

    Zhang Hao; Bi Fengchuan; Che Junxia; Zhang Jianwen; Yang Bo

    2014-01-01

    The paper studied that the test of diesel generator full load take-up under the condition of actual safety injection and reactor vessel closed in Ningde nuclear project unit l. It is proved that test result accorded with design criteria, meanwhile, the test was removed from the key path of project schedule, which cut a huge cost. (authors)

  1. Comparison of long-term voice outcomes after vocal fold augmentation using autologous fat injection by direct microlaryngoscopy versus office-based calcium hydroxylapatite injection.

    Science.gov (United States)

    Zeleník, Karol; Walderová, Radana; Kučová, Hana; Jančatová, Debora; Komínek, Pavel

    2017-08-01

    The objective is to compare the long-term voice outcomes of vocal fold augmentation (VFA) using autologous fat injection via direct microlaryngoscopy versus office-based calcium hydroxylapatite (CaHA) injection. Patients with glottal insufficiency and a gap no greater than 3 mm caused by unilateral vocal fold paralysis or vocal fold atrophy were prospectively recruited to the study from September 2012 to September 2015. From September 2012 to May 2014, VFA was only performed using autologous fat via direct microlaryngoscopy under general anesthesia (N = 14). From May 2014 to September 2015, VFA was performed as an office-based procedure using a transoral approach to inject CaHA (N = 17). Videolaryngostroboscopic evaluation, subjective satisfaction with voice, voice handicap index (VHI), and maximal phonation time (MPT) were analyzed pre-injection and 12 months after VFA. A total of 31 patients were analyzed. One year after VFA, 67.8% of the patients were satisfied with their voice, with no significant difference between groups (P = 0.247). The mean improvement in VHI in the autologous fat group was 31.6 ± 16.82 versus 35 ± 27.24 in the CaHA group (P = 0.664). MPT improvement was also similar in the two groups: 5.5 ± 2.52 for the autologous fat group versus 6.0 ± 3.98 for the CaHA group (P = 0.823). Both autologous fat injection via direct microlaryngoscopy and office-based CaHA injection have good long-term results. There were no differences in the treatment results of the two procedures 1 year after injection.

  2. Proportion of long-term injection drug users as an indicator to characterize the state and prognosis of HIV-epidemic within a certain territory

    Directory of Open Access Journals (Sweden)

    Andreeva, Tatiana

    2012-07-01

    Full Text Available BACKGROUND: Epidemics of drug use and thus the spread of HIV have different duration in different regions, and, therefore, the prognosis of these epidemics may differ. We aimed to assess indicators measuring the peculiarities of injection drug use epidemics by region, informative for prevention activities among vulnerable to HIV groups. METHODS: Data from cross-sectional survey of 4026 injection drug users (IDUs conducted in 2007 in Ukraine were analyzed. The outcome measure was a binary variable depicting whether a respondent injects drugs for 20 years and over. Binary Logistic Regression in SPSS software was used to test associations with socio-demographic characteristics. RESULTS: More respondents from Odessa, Mykolayiv, Dnipropetrovsk, Cherkassy, Poltava, and Crimea regions inject over 20 years. Older respondents were more likely to belong to the group of long-term users. Men were more likely to inject over 20 years than women. Those respondents who were married, but did not live with their spouse or other sexual partner were more likely to inject longer than 20 years compared to those single or in a stable marriage. Those respondents who use opiates or combine them with stimulants were more likely to inject over 20 years and those who use only stimulants were more likely to inject less than 20 years. CONCLUSION: Injection drug use in Ukraine started earlier among men, on certain territories and was associated with opiate use. Percentage of IDUs who inject for more than 20 years was found to be a good indicator to distinguish territories with long-lasting epidemics.

  3. Sample and injection manifolds used to in-place test of nuclear air-cleaning system

    International Nuclear Information System (INIS)

    Qiu Dangui; Li Xinzhi; Hou Jianrong; Qiao Taifei; Wu Tao; Zhang Jirong; Han Lihong

    2012-01-01

    Objective: According to the regulations of nuclear safety rules and related standards, in-place test of the nuclear air-cleaning systems should be carried out before and during operation of the nuclear facilities, which ensure them to be in good condition. In some special conditions, the use of sample and injection manifolds is required to make the test tracer and ventilating duct air fully mixed, so as to get the on-spot typical sample. Methods: This paper introduces the technology and application of the sample and injection manifolds in nuclear air-cleaning system. Results: Multi point injection and multi point sampling technology as an effective experimental method, has been used in a of domestic and international nuclear facilities. Conclusion: The technology solved the problem of uniformly of on-spot injection and sampling,which plays an important role in objectively evaluating the function of nuclear air-cleaning system. (authors)

  4. Short-term consistency testing vs. long-term behavior

    International Nuclear Information System (INIS)

    Ebert, W.L.; Bakel, A.J.; Wolf, S.F.; Strachan, D.M.

    1997-01-01

    The authors conducted Product Consistency Tests (PCTs) with a surrogate low-activity waste (LAW) glass to (1) evaluate the possible use of various test conditions in a specification test for LAW waste forms, (2) measure the reproducibility of the test at low temperatures, and (3) determine if the rates calculated from 7-day PCTs bound the rates measured in PCT conducted for longer durations, which represent more advanced corrosion. The effects of temperature and pH on the dissolution rate in PCTs are much less than the effects observed in dilute solutions due to the buildup of dissolved glass components in the PCTs. The precision of replicate 7-day tests at 20 and 40 degrees C was limited by the analytical uncertainty. The dissolution rates at all temperatures decreased with the test duration initially. However, the dissolution rates in tests at 70 and 90 degrees C increased when certain alteration phases formed after about 100 and 500 days, respectively; the rates in some tests exceeded that measured in a 7-day PCT. While the 7-day PCT does not provide a bounding rate for this glass at 70 or 90 degrees C, tests for longer durations are needed to determine if a 7-day test provides a bounding rate at lower temperatures

  5. Air-injection testing in vertical boreholes in welded and nonwelded Tuff, Yucca Mountain, Nevada

    Energy Technology Data Exchange (ETDEWEB)

    LeCain, G.D.

    1997-12-31

    Air-injection tests, by use of straddle packers, were done in four vertical boreholes (UE-25 UZ-No.16, USW SD-12, USW NRG-6, and USW NRG-7a) at Yucca Mountain, Nevada. The geologic units tested were the Tiva Canyon Tuff, nonwelded tuffs of the Paintbrush Group, Topopah Spring Tuff, and Calico Hills Formation. Air-injection permeability values of the Tiva Canyon Tuff ranged from 0.3 x 10{sup -12} to 54.0 x 10{sup -12} m{sup 2}(square meter). Air-injection permeability values of the Paintbrush nonwelded tuff ranged from 0.12 x 10{sup -12} to 3.0 x 10{sup -12} m{sup 2}. Air-injection permeability values of the Topopah Spring Tuff ranged from 0.02 x 10{sup -12} to 33.0 x 10{sup -12} m{sup 2}. The air-injection permeability value of the only Calico Hills Formation interval tested was 0.025 x 10{sup -12} m{sup 2}. The shallow test intervals of the Tiva Canyon Tuff had the highest air-injection permeability values. Variograms of the air-injection permeability values of the Topopah Spring Tuff show a hole effect; an initial increase in the variogram values is followed by a decrease. The hole effect is due to the decrease in permeability with depth identified in several geologic zones. The hole effect indicates some structural control of the permeability distribution, possibly associated with the deposition and cooling of the tuff. Analysis of variance indicates that the air-injection permeability values of borehole NRG-7a of the Topopah Spring Tuff are different from the other boreholes; this indicates areal variation in permeability.

  6. Study on scan timing using a test injection method in head CTA

    International Nuclear Information System (INIS)

    Sekito, Yuichi; Sanada, Hidenori

    2005-01-01

    In head computed tomographic angiography (CTA), circulation from arterial phase to venous phase is more rapid than that in other regions. Therefore, it is necessary to determine correct scan timing to obtain ideal CTA images. A test injection method makes it possible to set correct scan timing from the time density curve (TDC) for each subject. The method, however, has a weak point that is a time lag in an arrival time at peak point of contrast medium on TDC between the test injection and the primary examination because of the difference in total volume of contrast medium used. The purpose of this study calculated the delay time on the TDC in both scans. We used the test injection method and the bolus tracking method in the primary examination. The average errors in start time (Δt1) and slope change time (Δt2) of the contrast medium on the TDC between test injection and primary examination were 0.15 sec and 3.05 sec, respectively. The results indicated that it was important to grasp the delay time in start time and peak arrival time of the contrast medium between test injection and primary examination to obtain ideal images in head CTA. (author)

  7. Admissions of injection drug users to drug abuse treatment following HIV counseling and testing.

    Science.gov (United States)

    McCusker, J; Willis, G; McDonald, M; Lewis, B F; Sereti, S M; Feldman, Z T

    1994-01-01

    The outcomes of counseling and testing programs related to human immunodeficiency virus (HIV) infection and risk of infection among injection drug users (IDUs) are not well known or understood. A counseling and testing outcome of potential public health importance is attaining admission to drug abuse treatment by those IDUs who are either infected or who are at high risk of becoming infected. The authors investigated factors related to admission to drug abuse treatment among 519 IDUs who received HIV counseling and testing from September 1987 through December 1990 at a men's prison and at community-based testing sites in Worcester, MA. By June 1991, 123 of the 519 IDUs (24 percent) had been admitted to treatment. Variables associated with their admission included a long history of drug injection, frequent recent drug injection, cleaning injection equipment using bleach, prior drug treatment, and a positive HIV test result. Logistic regression analyses, controlling for effects of recruitment site, year, sex, and area of residence, generally confirmed the associations. IDUs in the study population who were HIV-infected sought treatment or were admitted to treatment more frequently than those who were not infected. The results indicate that access to drug abuse treatment should be facilitated for high-risk IDUs and for those who have begun to inject drugs recently.

  8. Verification test for radiation reduction effect and material integrity on PWR primary system by zinc injection

    Energy Technology Data Exchange (ETDEWEB)

    Kawakami, H.; Nagata, T.; Yamada, M. [Nuclear Power Engineering Corp. (Japan); Kasahara, K.; Tsuruta, T.; Nishimura, T. [Mitsubishi Heavy Industries, Ltd. (Japan); Ishigure, K. [Saitama Inst. of Tech. (Japan)

    2002-07-01

    Zinc injection is known to be an effective method for the reduction of radiation source in the primary water system of a PWR. There is a need to verify the effect of Zn injection operation on radiation source reduction and materials integrity of PWR primary circuit. In order to confirm the effectiveness of Zn injection, verification test as a national program sponsored by Ministry of Economy, Trade and Industry (METI) was started in 1995 for 7-year program, and will be finished by the end of March in 2002. This program consists of irradiation test and material integrity test. Irradiation test as an In-Pile-Test managed by AEAT Plc(UK) was performed using the LVR-15 reactor of NRI Rez in Check Republic. Furthermore, Out-of-Pile-Test using film adding unit was also performed to obtain supplemental data for In-Pile-Test at Takasago Engineering Laboratory of NUPEC. Material Integrity test was planned to perform constant load test, constant strain test and corrosion test at the same time using large scale Loop and slow strain extension rate testing (SSRT) at Takasago Engineering Laboratory of NUPEC. In this paper, the results of the verification test for Zinc program at present are discussed. (authors)

  9. Short-term disposition of TCDD in rats after iv injection

    International Nuclear Information System (INIS)

    Ernst, S.W.; Weber, L.W.D.; Rozman, K.; Stahl, B.U.

    1990-01-01

    Male Sprague-Dawley rats (235-290gr) were injected iv via tail vein with 14 C-TCDD (10 μg/kg, 1 μCi/kg) in a 10% oil/water emulsion (4 ml/kg). 4 rats per group were sacrificed 5, 15 or 45 minutes and 3, 8 or 24 hours after dosing. TCDD attained highest radioactivity levels immediately after injection in blood and in tissues with high blood flow such as lung, spleen, heart, olfactory epithelium (maximum at 5 min post injection), brown adipose tissue and muscle (15 min). At 5 min these tissues accounted for about 30% of total radioactivity. The disposition profile of 14 C-radioactivity was 1st order biphasic with the first phase lasting less than 3 hrs. After this time radioactivity levels in blood were lowest of all tissues. Low-perfused tissues such as skin and white adipose tissue (WAT) displayed distinct uptake phases with peak levels of radioactivity occurring after 8 and 24 hours, respectively. Liver, a major target and storage organ of TCDD toxicity, reached 80% of maximum within 45 min and maximum by 8 hours; about 45% of dose were associated with liver tissue at these time points. This is consistent with a two-phase short-term tissue distribution of TCDD. During the first phase most of the TCDD dissolved in oil spheres distributed into highly perfused organs; during the following phase it was redistributed to poorly perfused, but rather lipophilic organs. Two tissues did not fit this pattern. Liver, highly perfused but lower in fat content than WAT, accumulated about one-half of total TCDD which is known to be bound to microsomal proteins. Brain, despite its high blood supply and lipophilicity, attained concentrations of TCDD comparable only to or even lower than in blood. This is surprising because it is in contrast to the disposition of other compounds with similar physicochemical properties

  10. Ambiguity in measuring matrix diffusion with single-well injection/recovery tracer tests

    Science.gov (United States)

    Lessoff, S.C.; Konikow, Leonard F.

    1997-01-01

    Single-well injection/recovery tracer tests are considered for use in characterizing and quantifying matrix diffusion in dual-porosity aquifers. Numerical modeling indicates that neither regional drift in homogeneous aquifers, nor heterogeneity in aquifers having no regional drift, nor hydrodynamic dispersion significantly affects these tests. However, when drift is coupled simultaneously with heterogeneity, they can have significant confounding effects on tracer return. This synergistic effect of drift and heterogeneity may help explain irreversible flow and inconsistent results sometimes encountered in previous single-well injection/recovery tracer tests. Numerical results indicate that in a hypothetical single-well injection/recovery tracer test designed to demonstrate and measure dual-porosity characteristics in a fractured dolomite, the simultaneous effects of drift and heterogeneity sometimes yields responses similar to those anticipated in a homogeneous dual-porosity formation. In these cases, tracer recovery could provide a false indication of the occurrence of matrix diffusion. Shortening the shut-in period between injection and recovery periods may make the test less sensitive to drift. Using multiple tracers having different diffusion characteristics, multiple tests having different pumping schedules, and testing the formation at more than one location would decrease the ambiguity in the interpretation of test data.

  11. Hot functional test chemistry - long term experience

    International Nuclear Information System (INIS)

    Vonkova, K.; Kysela, J.; Marcinsky, M.; Martykan, M.

    2010-01-01

    Primary circuit materials undergo general corrosion in high temperature, deoxygenated, neutral or mildly alkaline solutions to form thin oxide films. These oxide layers (films) serve as protective film and mitigate the further corrosion of primary materials. Inner chromium-rich oxide layer has low cation diffusion coefficients and thus control iron and nickel transport from the metal surface to the outer layer and their dissolution into the coolant. Much less corrosion products are generated by the compact, integral and stable oxide (passivation) layer. For the latest Czech and Slovak stations commissioned (Temelin and Mochovce) a modified Hot Functional Test (HFT) chemistry was developed in the NRI Rez. Chromium rich surface layer formatted due to modified HTF chemistry ensures lower corrosion rates and radiation field formation and thus also mitigates crud formation during operation. This procedure was also designed to prepare the commissioned unit for the further proper water chemistry practise. Mochovce 1 (SK) was the first station commissioned using these recommendations in 1998. Mochovce 2 (1999) and Temelin 1 and 2 (CZ - 2000 and 2002) were subsequently commissioned using these guidelines too. The main principles of the controlled primary water chemistry applied during the hot functional tests are reviewed and importance of the water chemistry, technological and other relevant parameters is stressed regarding to the quality of the passive layer formed on the primary system surfaces. Samples from Mochovce indicated that duplex oxide layers up to 20 μm thick were produced, which were mainly magnetite substituted with nickel and chromium (e.g. 60-65% Fe, 18-28% Cr, 9-12% Ni, <1% Mn and 1-2% Si on a stainless steel primary circuit sample). Long term operation experience from both nuclear power plants are discussed in this paper. Radiation field, occupational radiation exposure and corrosion layers evolution during the first c. ten years of operation are

  12. Zinc injection during Hot Functional Test (HFT) in Tomari Unit 3

    International Nuclear Information System (INIS)

    Hayakawa, H.; Mino, Y.; Nakahama, S.; Aizawa, Y.; Nishimura, T.; Umehara, R.; Shimuz, Y.; Kogawa, N.; Ojima, Z.

    2010-01-01

    Zinc injection is performed to reduce radiation exposure around the world, and its effect is confirmed. In Japanese PWRs, the actual effect is also confirmed. Therefore, number of Japanese PWR plans, where zinc is injected, increase. We conclude that zinc injection from Hot Function Test (HFT), when RCS temperature and corrosion rate of material of primary components are increased firstly, is more effective for reducing radiation exposure, because oxide layer with zinc is more stable than with other metals such as cobalt and it is confirmed that zinc injection reduces corrosion amount of alloy 690TT in laboratory test. Therefore in Tomari Unit 3 (PWR, commercial operation from December 2009) of HOKKAIDO ELECTRIC POWER CO., INC, zinc injection was started from first Heat-up during trial operation. During HFT, zinc consumption coincides with assumed plan and Ni concentration is lower than in reference plant. Therefore we conclude that stable and fine oxide layer including zinc is formed. We hope that radiation exposure reduces because of these results. (We published at Asia Water Chemistry Symposium 2009 in NAGOYA.) Results of analysis of oxide layer on SG insert plate, removed after HFT, will be reported. Also Actual results of water chemistry and zinc injection after HFT will be reported. (author)

  13. Treatment of achalasia: the short-term response to botulinum toxin injection seems to be independent of any kind of pretreatment

    Directory of Open Access Journals (Sweden)

    Meining A

    2002-08-01

    Full Text Available Abstract Background It has been suggested that intrasphincteric injection of botulinum toxin (BTX may represent an alternative therapy to balloon dilatation in achalasia. The aim of the present study was to test the effectiveness of botulinum toxin injections in achalasia patients, as assessed using lower oesophageal sphincter pressure (LOSP and symptom scores, and to compare the response in patients with different types of pretreatment (no previous treatment, balloon dilatation, myotomy, BTX injection. Methods Forty patients who presented with symptomatic achalasia were treated with BTX injection (48 injections in 40 patients. Some of the patients had received prior treatment (seven with myotomy, seven with dilatation and eight with BTX. The symptoms were assessed using a global symptom score (0–10, which was evaluated before treatment, 1 week afterwards, and 1 month afterwards. Manometry was also carried out before and after treatment. Three different selections of patients were studied: all patients; untreated patients; and patients with prior BTX, dilatation, or myotomy. Results After BTX injection, there was a significant reduction in LOSP (before, 38.2 ± 11.3 mmHg; 1 week after, 20.5 ± 6.9 mmHg; 1 month after, 17.8 ± 6.8 mmHg; P Conclusions BTX injection offers an alternative treatment for achalasia which is safe and can be performed in an outpatient setting. The initial response to BTX, in terms of symptom scores and LOSP, appears to be independent of any prior treatment. A number of patients do not adequately respond to balloon dilatation or myotomy, which are the first-line treatment modalities in achalasia patients. BTX injection can be performed in these patients, and symptomatic benefit can be expected in the same percentages as with BTX injection in untreated patients.

  14. Long-term Results of Percutaneous Ethanol Injection for the Treatment of Hepatocellular Carcinoma in Korea

    International Nuclear Information System (INIS)

    Sung, Yon Mi; Choi, Don Gil; Lim, Hyo K.

    2006-01-01

    To evaluate the long-term follow-up results of percutaneous ethanol injection (PEI) for the treatment of hepatocellular carcinoma (HCC) in Korea. Sixty-eight nodular HCCs initially detected in 64 patients, were subjected to US-guided PEI as a first-line treatment. Long-term survival rates, local tumor progression rates, and complications were evaluated, as were the influences of tumor size and Child-Pugh class on these variables. No major complications occurred. The overall survival rates of the 64 patients at three and five years were 71% and 39%, and their cancer-free survival rates were 22% and 15%, respectively. The overall survival rate of patients with a small HCC (≤ 2 cm) was significantly higher (p = 0.014) than that of patients with a medium-sized HCC (≤ 2 cm). The overall survival rate of patients with Child- Pugh class A was significantly higher (p = 0.049) than that of patients with Child- Pugh class B. Of 59 cases with no residual tumor, local tumor progression was observed in ablation zones in 18, and this was not found to be significantly influenced by tumor size or Child-Pugh class. The results of our investigation of the long-term survival rates of PEI in HCC patients in Korea (a hepatitis B virus-endemic area) were consistent with those reported previously in hepatitis C endemic areas. Patients with a smaller tumor or a better liver function exhibited superior survival rates

  15. Intermediate Scale Laboratory Testing to Understand Mechanisms of Capillary and Dissolution Trapping during Injection and Post-Injection of CO2 in Heterogeneous Geological Formations

    Energy Technology Data Exchange (ETDEWEB)

    Illangasekare, Tissa [Colorado School of Mines, Golden, CO (United States); Trevisan, Luca [Colorado School of Mines, Golden, CO (United States); Agartan, Elif [Colorado School of Mines, Golden, CO (United States); Mori, Hiroko [Colorado School of Mines, Golden, CO (United States); Vargas-Johnson, Javier [Colorado School of Mines, Golden, CO (United States); Gonzalez-Nicolas, Ana [Colorado School of Mines, Golden, CO (United States); Cihan, Abdullah [Colorado School of Mines, Golden, CO (United States); Birkholzer, Jens [Colorado School of Mines, Golden, CO (United States); Zhou, Quanlin [Colorado School of Mines, Golden, CO (United States)

    2015-03-31

    Carbon Capture and Storage (CCS) represents a technology aimed to reduce atmospheric loading of CO2 from power plants and heavy industries by injecting it into deep geological formations, such as saline aquifers. A number of trapping mechanisms contribute to effective and secure storage of the injected CO2 in supercritical fluid phase (scCO2) in the formation over the long term. The primary trapping mechanisms are structural, residual, dissolution and mineralization. Knowledge gaps exist on how the heterogeneity of the formation manifested at all scales from the pore to the site scales affects trapping and parameterization of contributing mechanisms in models. An experimental and modeling study was conducted to fill these knowledge gaps. Experimental investigation of fundamental processes and mechanisms in field settings is not possible as it is not feasible to fully characterize the geologic heterogeneity at all relevant scales and gathering data on migration, trapping and dissolution of scCO2. Laboratory experiments using scCO2 under ambient conditions are also not feasible as it is technically challenging and cost prohibitive to develop large, two- or three-dimensional test systems with controlled high pressures to keep the scCO2 as a liquid. Hence, an innovative approach that used surrogate fluids in place of scCO2 and formation brine in multi-scale, synthetic aquifers test systems ranging in scales from centimeter to meter scale developed used. New modeling algorithms were developed to capture the processes controlled by the formation heterogeneity, and they were tested using the data from the laboratory test systems. The results and findings are expected to contribute toward better conceptual models, future improvements to DOE numerical codes, more accurate assessment of storage capacities, and optimized placement strategies. This report presents the experimental and modeling methods

  16. Safety of radiofrequency treatment over human skin previously injected with medium-term injectable soft-tissue augmentation materials: a controlled pilot trial.

    Science.gov (United States)

    Alam, Murad; Levy, Ross; Pajvani, Urvi; Pavjani, Urvi; Ramierez, James A; Guitart, Joan; Veen, Heather; Gladstone, Hayes B

    2006-03-01

    Several soft-tissue augmentation materials are now available for reduction of nasolabial fold creases and perioral rhytides. Nasolabial folds and perioral rhytides can also be improved by skin tightening delivered by non-ablative radiofrequency (RF) treatment. The purpose of this study was to assess the safety of RF treatment over skin areas recently injected with medium-term injectable soft-tissue augmentation materials. Five subjects were assigned to the experimental arm (augmentation materials plus RF) and one to the control arm (augmentation materials alone). Each subject received injections of 0.3 mL of hyaluronic acid derivative (Restylane) and calcium hydroxylapatite (Radiesse) 3 cm apart on the upper inner arm. Two weeks later, two non-overlapping passes of RF (Thermage ThermaCool TC) were delivered at 63.5 setting with medium-fast 1.5 cm2 tip over injected sites in all of the experimental subjects. Punch skin biopsies were obtained 3 days later from each of the two injection sites on each subject. Light microscopy and digital photomicrographs obtained at low, medium, and high power showed no difference between filler materials in experimental and control subjects. In both cases filler was evident at the deep dermal-subcutaneous junction. Nodule formation, foreign body extravasation, or hemorrhage/clot was not observed grossly or histologically. Subjects and physicians did not report any difference in signs and symptoms between the experimental and control arms. Slightly increased transitory pain was noted when RF was delivered over filler versus over normal skin. Applying RF treatment over the same area 2 weeks after deep dermal injection with hyaluronic acid derivatives or calcium hydroxylapatite does not appear to cause gross morphological changes in the filler material or surrounding skin. Further studies with different parameters are necessary to confirm these findings. 2006 Wiley-Liss, Inc.

  17. Short-term cessation of sex work and injection drug use: evidence from a recurrent event survival analysis.

    Science.gov (United States)

    Gaines, Tommi L; Urada, Lianne A; Martinez, Gustavo; Goldenberg, Shira M; Rangel, Gudelia; Reed, Elizabeth; Patterson, Thomas L; Strathdee, Steffanie A

    2015-06-01

    This study quantitatively examined the prevalence and correlates of short-term sex work cessation among female sex workers who inject drugs (FSW-IDUs) and determined whether injection drug use was independently associated with cessation. We used data from FSW-IDUs (n=467) enrolled into an intervention designed to increase condom use and decrease sharing of injection equipment but was not designed to promote sex work cessation. We applied a survival analysis that accounted for quit-re-entry patterns of sex work over 1-year stratified by city, Tijuana and Ciudad Juarez, Mexico. Overall, 55% of participants stopped sex work at least once during follow-up. Controlling for other characteristics and intervention assignment, injection drug use was inversely associated with short-term sex work cessation in both cities. In Ciudad Juarez, women receiving drug treatment during follow-up had a 2-fold increase in the hazard of stopping sex work. In both cities, income from sources other than sex work, police interactions and healthcare access were independently and significantly associated with shorter-term cessation. Short-term sex work cessation was significantly affected by injection drug use. Expanded drug treatment and counseling coupled with supportive services such as relapse prevention, job training, and provision of alternate employment opportunities may promote longer-term cessation among women motivated to leave the sex industry. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. Data Acquisition for Low-Temperature Geothermal Well Tests and Long-Term Monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Lienau, P J

    1992-03-01

    Groundwater monitoring is an essential part of the development of a low-temperature geothermal field for production and injection wells. State water resource and environmental departments are requiring both geothermal well testing and long-term monitoring as a part of the permitting process for geothermal developments. This report covers water-level measurement methods, instruments used for well testing, geochemical sampling, examples of data acquisition and regulatory mandates on groundwater monitoring.

  19. Data acquisition for low-temperature geothermal well tests and long-term monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Lienau, P.J.

    1992-09-01

    Groundwater monitoring is an essential part of the development of a low-temperature geothermal field for production and injection wells. State water resource and environmental departments are requiring both geothermal well testing and long-term monitoring as a part of the permitting process for geothermal developments. This report covers water-level measurement methods, instruments used for well testing, geochemical sampling, examples of data acquisition and regulatory mandates on groundwater monitoring.

  20. Quick Look Report of the SMART ECC injection performance test I3

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Seok; Ko, Yong Ju; Cho, Young Il; Kim, Jeong Tak; Choi, Nam Hyun; Park, Choon Kyong; Kwon, Tae Soon; Lee, Sung Jae [KAERI, Daejeon (Korea, Republic of)

    2010-12-15

    The objective of this report is to describe test results of the Test I3 simulating the 2 inch SBLOCA of the SMART using the SWAT test facility. The Test I3 was performed to produce experimental data for the validation of the TASS/SMR-S thermal hydraulic analysis code, and to investigate the related thermal hydraulic phenomena in the down-comer region during the 2 inch SBLOCA of the safety inject line. The particular phenomena for the observation are ECC bypass and multi-dimensional flow characteristics to verify the effectiveness and performance of the safety injection system. In this report, the corresponding steady state test conditions, including initial and boundary conditions along with major measuring parameters, and related experimental results were described

  1. Percutaneous ethanol injection of hyperfunctioning thyroid nodules: long-term follow-up in 125 patients.

    Science.gov (United States)

    Tarantino, Luciano; Francica, Giampiero; Sordelli, Ignazio; Sperlongano, Pasquale; Parmeggiani, Domenico; Ripa, Carmine; Parmeggiani, Umberto

    2008-03-01

    The purpose of this study was to assess the long-term efficacy of percutaneous ethanol injection (PEI) for the treatment of hyperfunctioning thyroid nodules. One hundred twenty-five patients (88 women, 37 men; age range, 17-76 years; mean age, 53 years) with 127 hyperfunctioning thyroid nodules (volume, 1.2-90 mL; mean, 10.3 mL) were treated with PEI. There were 1-11 PEI sessions per patient (average, 3.9) performed, with injection of 1-14 mL of ethanol per session (total injected ethanol per patient, 3-108 mL; mean, 14.0 mL). Efficacy of the treatment was assessed with color Doppler sonography; scintigraphy; and free triiodothyronine (FT3), free thyroxine (FT4), and thyroid-stimulating hormone (TSH) assays. Follow-up (9-144 months; median, 60 months) was performed with TSH and color Doppler sonography every 2 months for 6 months and every 6 months thereafter. Three (2.4%) of 125 patients refused completion of PEI therapy because of pain. Results are reported in 122 patients with 124 nodules. All 122 patients showed posttreatment normal levels of FT3, FT4, and TSH. A complete cure (absent uptake in the nodule and recovery of normal uptake in the thyroid parenchyma) was obtained in 113 (93%) of 122 patients-115 (92.7%) of 124 treated nodules. Residual hyperfunctioning nodular tissue along with decreased thyroid parenchyma uptake (partial cure) was present in nine patients accounting for nine (7.3%) of 124 nodules. Rates of complete cure after PEI were: overall nodules, 115 (92.7%) of 124; nodules nodules > 10 to nodules > 30 to nodules > 60 mL, three (100%) of three. The overall rate of major complications (transient laryngeal nerve damage, two patients; abscess and hematoma, one patient each) was four (3.2%) of 125 patients. Follow-up examinations showed marked shrinkage of 112 treated nodules ranging from 50% to 90% of the pretreatment volume (mean, 66%) and new growth of hyperfunctioning tissue in four patients at color Doppler sonography and scintigraphy at 12

  2. A field test of a waste containment technology using a new generation of injectable barrier liquids

    International Nuclear Information System (INIS)

    Moridis, G.; Apps, J.; Persoff, P.; Myer, L.; Muller, S.; Pruess, K.; Yen, P.

    1996-08-01

    A first stage field injection of a new generation of barrier liquids was successfully completed. Two types of barrier liquids, colloidal silica (CS) and polysiloxane (PSX), were injected into heterogeneous unsaturated deposits of sand, silt, and gravel typical of many of the arid DOE cleanup sites and particularly analogous to the conditions of the Hanford Site. Successful injection by commercially available chemical grouting equipment and the tube-a-manchette technique was demonstrated. Excavation of the grout bulbs permitted visual evaluation of the soil permeation by the grout, as well as sample collection. Both grouts effectively permeated all of the formation. The PSX visually appeared to perform better, producing a more uniform and symmetric permeation regardless of heterogeneity, filling large as well as small pores and providing more structural strength than the CS. Numerical simulation of the injection tests incorporated a stochastic field to represent site heterogeneity and was able to replicate the general test behavior. Tiltmeters were used successfully to monitor surface displacements during grout injection

  3. TEST DESIGN FOR ENVIRONMENTAL TECHNOLOGY VERIFICATION (ETV) OF ADD-ON NOX CONTROL UTILIZING OZONE INJECTION

    Science.gov (United States)

    The paper discusses the test design for environmental technology verification (ETV) of add-0n nitrogen oxides (NOx) control utilizing ozone injection. (NOTE: ETV is an EPA-established program to enhance domestic and international market acceptance of new or improved commercially...

  4. Finalize field testing of cold climate heat pump (CCHP) based on tandem vapor injection compressors

    Energy Technology Data Exchange (ETDEWEB)

    Shen, Bo [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Baxter, Van D. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Abdelaziz, Omar [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Rice, C. Keith [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-03-01

    This report describes the system diagram and control algorithm of a prototype air-source cold climate heat pump (CCHP) using tandem vapor injection (VI) compressors. The prototype was installed in Fairbanks, Alaska and underwent field testing starting in 09/2016. The field testing results of the past six months, including compressor run time fractions, measured COPs and heating capacities, etc., are presented as a function of the ambient temperature. Two lessons learned are also reported.

  5. Test facility for fast gas injections into a vessel filled with water

    International Nuclear Information System (INIS)

    Wilhelm, D.; Kirstahler, M.

    1987-11-01

    The Fast Gas Injection Facility (SGI) was set up to study the hydrodynamics during the expansion of a gas bubble into a vessel filled with water. The gas stored in a pressure vessel expands against gravity through a circular duct into a large cylindrical vessel partly with water. This report covers the description of the test facility and the data acquisition. Results of the first test series are added. (orig.) [de

  6. Validation of precision powder injection molding process simulations using a spiral test geometry

    DEFF Research Database (Denmark)

    Marhöfer, Maximilian; Müller, Tobias; Tosello, Guido

    2015-01-01

    Like in many other areas of engineering, process simulations find application in precision injection molding to assist and optimize the quality and design of precise products and the molding process. Injection molding comprises mainly the manufacturing of plastic components. However, the variant ....... The necessary data and the implementation procedure of the new material models are outlined. In order to validate the simulation studies and evaluate their accuracy, the simulation results are compared with experiments performed using a spiral test geometry...... for powder injection molding. This characterization includes measurements of rheological, thermal, and pvT behavior of the powder-binder-mixes. The acquired material data was used to generate new material models for the database of the commercially available Autodesk Moldflow® simulation software...

  7. THE STUDY OF GAS MIGRATION IN CRYSTALLINE ROCK USING INJECTION TESTS

    Directory of Open Access Journals (Sweden)

    Jiří Svoboda

    2012-07-01

    Full Text Available The study of gas migration in crystalline rock using injection tests is being carried out in the frame of the FORGE (Fate of Repository Gases project. The Czech Technical University in Prague (CTU, Centre of Experimental Geotechnics (CEG is participating in WP4 which is focused on disturbed host rock formations with respect to radioactive waste deep repositories. A series of in-situ tests is being conducted at the Josef Underground Laboratory. The aim of the testing is to simulate and study phenomena that might lead to gas-driven radionuclide transport in fractured crystalline rock. The in-situ tests combine migration and large-scale gas injection measurements; gas injection tests are being employed for the study of gas transport. For the purposes of comparison of the behaviour of the rock mass with regard to air and water a series of water pressure tests are also being carried out. The quality of the rock mass is assessed using rock mass classification systems.

  8. Relevant climate response tests for stratospheric aerosol injection: A combined ethical and scientific analysis

    Science.gov (United States)

    Lenferna, Georges Alexandre; Russotto, Rick D.; Tan, Amanda; Gardiner, Stephen M.; Ackerman, Thomas P.

    2017-06-01

    In this paper, we focus on stratospheric sulfate injection as a geoengineering scheme, and provide a combined scientific and ethical analysis of climate response tests, which are a subset of outdoor tests that would seek to impose detectable and attributable changes to climate variables on global or regional scales. We assess the current state of scientific understanding on the plausibility and scalability of climate response tests. Then, we delineate a minimal baseline against which to consider whether certain climate response tests would be relevant for a deployment scenario. Our analysis shows that some climate response tests, such as those attempting to detect changes in regional climate impacts, may not be deployable in time periods relevant to realistic geoengineering scenarios. This might pose significant challenges for justifying stratospheric sulfate aerosol injection deployment overall. We then survey some of the major ethical challenges that proposed climate response tests face. We consider what levels of confidence would be required to ethically justify approving a proposed test; whether the consequences of tests are subject to similar questions of justice, compensation, and informed consent as full-scale deployment; and whether questions of intent and hubris are morally relevant for climate response tests. We suggest further research into laboratory-based work and modeling may help to narrow the scientific uncertainties related to climate response tests, and help inform future ethical debate. However, even if such work is pursued, the ethical issues raised by proposed climate response tests are significant and manifold.

  9. Long-term Dose Stability of OnabotulinumtoxinA Injection for Adductor Spasmodic Dysphonia: A 19-Year Single Institution Experience

    Directory of Open Access Journals (Sweden)

    Paul Paddle

    2017-11-01

    Full Text Available ObjectivesAdductor spasmodic dysphonia (AdSD is a focal dystonia predominantly involving the laryngeal adductor muscles. AdSD is reported to be a largely non-progressive neurological disorder, though fluctuations in symptom severity do occur. Repeated laryngeal onabotulinumtoxinA (BTX-A injections are the primary management for AdSD. A number of studies have demonstrated long-term dose stability as evidence of this long-term disease stability.MethodsA retrospective review was performed on all patients undergoing BTX-A injections for AdSD from April 1994 to September 2013 by a single laryngologist at a tertiary referral laryngology center. Patient demographics, injection doses, use of diazepam and/or lidocaine, and self-reported vocal function were recorded. Multiple linear regression analyses were performed.Results83 patients underwent a total of 1,168 injections over 19 years. The mean starting dose was 2.35 MU (0.79 SD. The mean long-term dose was 2.36 MU (0.79 SD. After adjusting for confounders, the change in the relative dose of BTX-A, with every year elapsed since initial dose was 0.13% (95% confidence interval −0.31 to 0.57%, p = 0.568.ConclusionBTX-A dose is stable over time in our large cohort of patients treated with bilateral thyroarytenoid injections for AdSD.

  10. Long-term results of percutaneous ethanol injection therapy for hepatocellular carcinoma in cirrhosis: a European experience

    International Nuclear Information System (INIS)

    Lencioni, R.; Pinto, F.; Armillotta, N.; Bassi, A.M.; Moretti, M.; Di Giulio, M.; Marchi, S.; Uliana, M.; Della Capanna, S.; Lencioni, M.; Bartolozzi, C.

    1997-01-01

    The objective of our work was to evaluate the long-term results of percutaneous ethanol injection (PEI) for the treatment of hepatocellular carcinoma (HCC) in patients with liver cirrhosis. A total of 184 cirrhotic patients with HCC underwent PEI as the only anticancer treatment over an 8-year period. Patients were followed after therapy by means of clinical examinations, laboratory tests, and US and CT studies performed at regular time intervals. Survival rates were determined according to the Kaplan-Meier method. The overall survival was 67% at 3 years, 41% at 5 years, and 19% at 7 years. The 3-, 5-, and 7-year survival rates of patients with single HCC≤3 cm (78, 54, and 28%, respectively) were significantly higher (p<0.01) than those of patients with single HCC of 3.1-5 cm (61, 32, and 16, respectively) or multiple HCCs (51, 21, and 0%, respectively). Survival of Child-Pugh A patients (79% at 3 years, 53% at 5 years, and 32% at 7 years) was significantly longer (p<0.01) than that of Child-Pugh B patients (50% at 3 years, 28% at 5 years, and 8% at 7 years). A selected group of 70 patients with Child-Pugh A cirrhosis and single HCC≤3 cm had a 7-year survival of 42%. Long-term survival of cirrhotic patients with HCC treated with PEI is comparable to that reported in published series of matched patients submitted to surgical resection. (orig.)

  11. A HWIL test facility of infrared imaging laser radar using direct signal injection

    Science.gov (United States)

    Wang, Qian; Lu, Wei; Wang, Chunhui; Wang, Qi

    2005-01-01

    Laser radar has been widely used these years and the hardware-in-the-loop (HWIL) testing of laser radar become important because of its low cost and high fidelity compare with On-the-Fly testing and whole digital simulation separately. Scene generation and projection two key technologies of hardware-in-the-loop testing of laser radar and is a complicated problem because the 3D images result from time delay. The scene generation process begins with the definition of the target geometry and reflectivity and range. The real-time 3D scene generation computer is a PC based hardware and the 3D target models were modeled using 3dsMAX. The scene generation software was written in C and OpenGL and is executed to extract the Z-buffer from the bit planes to main memory as range image. These pixels contain each target position x, y, z and its respective intensity and range value. Expensive optical injection technologies of scene projection such as LDP array, VCSEL array, DMD and associated scene generation is ongoing. But the optical scene projection is complicated and always unaffordable. In this paper a cheaper test facility was described that uses direct electronic injection to provide rang images for laser radar testing. The electronic delay and pulse shaping circuits inject the scenes directly into the seeker's signal processing unit.

  12. Evaluation of the long-term efficacy of CT-guided epidural steroid injection for the treatment of sciatica

    International Nuclear Information System (INIS)

    Tong Guohai; Wang Wei; Chen Wei; Chen Kemin

    2005-01-01

    Objective: To evaluate the long-term efficacy of CT-guided epidural steroid injection for the treatment of sciatica. Methods: CT-guided epidural steroid injection was performed in 180 patients with sciatica from May 1998 to March 2004, and all patients had failure to previous conservative treatment. Visual analogue scale was used to evaluate the pain of the patient before and after the treatment. Results: Follow-up was taken for 112 cases during 1-6 years after the treatment, 89 patients (79.5%) had successful long-term outcome and 80 patients (71.4%) were satisfied. Conclusions: CT-guided epidural steroid injection can reduce low back pain and radical pain. It should be preferentially considered as the first choice when conservative treatments are failed. (authors)

  13. The value of short-term pain relief in predicting the long-term outcome of 'indirect' cervical epidural steroid injections.

    Science.gov (United States)

    Joswig, Holger; Neff, Armin; Ruppert, Christina; Hildebrandt, Gerhard; Stienen, Martin Nikolaus

    2018-05-01

    The predictive value of short-term arm pain relief after 'indirect' cervical epidural steroid injection (ESI) for the 1-month treatment response has been previously demonstrated. It remained to be answered whether the long-term response could be estimated by the early post-interventional pain course as well. Prospective observational study, following a cohort of n = 45 patients for a period of 24 months after 'indirect' ESI for radiculopathy secondary to a single-level cervical disk herniation (CDH). Arm and neck pain on the visual analog scale (VAS), health-related quality of life with the Short Form-12 (SF-12), and functional outcome with the Neck Pain and Disability (NPAD) Scale were assessed. Any additional invasive treatment after a single injection (second injection or surgery) defined treatment outcome as 'non-response'. At 24 months, n = 30 (66.7%) patients were responders and n = 15 (33.3%) were non-responders. Non-responders exited the follow-up at 1 month (n = 10), at 3 months (n = 4), and at 6 months (n = 1). No patients were injected again or operated on between the 6- and 24-month follow-up. Patients with favorable treatment response at 24 months had significantly lower VAS arm pain (p  50% short term pain reduction was not a reliable predictor of the 24-month responder status. SF-12 and NPAD scores were better among treatment responders in the long term. Patients who require a second injection or surgery after 'indirect' cervical ESI for a symptomatic CDH do so within the first 6 months. Short-term pain relief cannot reliably predict the long-term outcome.

  14. Long-Term Effects of Botulinum Toxin Complex Type A Injection on Mechano- and Metabo-Sensitive Afferent Fibers Originating from Gastrocnemius Muscle.

    Directory of Open Access Journals (Sweden)

    Guillaume Caron

    Full Text Available The aim of the present study was to investigate long term effects of motor denervation by botulinum toxin complex type A (BoNT/A from Clostridium Botulinum, on the afferent fibers originating from the gastrocnemius muscle of rats. Animals were divided in 2 experimental groups: 1 untreated animals acting as control and 2 treated animals in which the toxin was injected in the left muscle, the latter being itself divided into 3 subgroups according to their locomotor recovery with the help of a test based on footprint measurements of walking rats: i no recovery (B0, ii 50% recovery (B50 and iii full recovery (B100. Then, muscle properties, metabosensitive afferent fiber responses to potassium chloride (KCl and lactic acid injections and Electrically-Induced Fatigue (EIF, and mechanosensitive responses to tendon vibrations were measured. At the end of the experiment, rats were killed and the toxin injected muscles were weighted. After toxin injection, we observed a complete paralysis associated to a loss of force to muscle stimulation and a significant muscle atrophy, and a return to baseline when the animals recover. The response to fatigue was only decreased in the B0 group. The responses to KCl injections were only altered in the B100 groups while responses to lactic acid were altered in the 3 injected groups. Finally, our results indicated that neurotoxin altered the biphasic pattern of response of the mechanosensitive fiber to tendon vibrations in the B0 and B50 groups. These results indicated that neurotoxin injection induces muscle afferent activity alterations that persist and even worsen when the muscle has recovered his motor activity.

  15. Long-Term Effects of Botulinum Toxin Complex Type A Injection on Mechano- and Metabo-Sensitive Afferent Fibers Originating from Gastrocnemius Muscle.

    Science.gov (United States)

    Caron, Guillaume; Marqueste, Tanguy; Decherchi, Patrick

    2015-01-01

    The aim of the present study was to investigate long term effects of motor denervation by botulinum toxin complex type A (BoNT/A) from Clostridium Botulinum, on the afferent fibers originating from the gastrocnemius muscle of rats. Animals were divided in 2 experimental groups: 1) untreated animals acting as control and 2) treated animals in which the toxin was injected in the left muscle, the latter being itself divided into 3 subgroups according to their locomotor recovery with the help of a test based on footprint measurements of walking rats: i) no recovery (B0), ii) 50% recovery (B50) and iii) full recovery (B100). Then, muscle properties, metabosensitive afferent fiber responses to potassium chloride (KCl) and lactic acid injections and Electrically-Induced Fatigue (EIF), and mechanosensitive responses to tendon vibrations were measured. At the end of the experiment, rats were killed and the toxin injected muscles were weighted. After toxin injection, we observed a complete paralysis associated to a loss of force to muscle stimulation and a significant muscle atrophy, and a return to baseline when the animals recover. The response to fatigue was only decreased in the B0 group. The responses to KCl injections were only altered in the B100 groups while responses to lactic acid were altered in the 3 injected groups. Finally, our results indicated that neurotoxin altered the biphasic pattern of response of the mechanosensitive fiber to tendon vibrations in the B0 and B50 groups. These results indicated that neurotoxin injection induces muscle afferent activity alterations that persist and even worsen when the muscle has recovered his motor activity.

  16. Microbiological analyses of samples from the H-Area injection well test site

    International Nuclear Information System (INIS)

    Wilde, E.W.; Franck, M.M.

    1997-01-01

    Microbial populations in well water from monitoring wells at the test site were one to three orders of magnitude higher than well water from the Cretaceous aquifer (used as dilution water for the tests) or from a control well adjacent to the test site facility. Coupons samples placed in monitoring and control wells demonstrated progressive adhesion by microbes to materials used in well construction. Samples of material scraped from test well components during abandonment of the test site project revealed the presence of a variety of attached microbes including iron bacteria. Although the injection wells at the actual remediation facility for the F- and H-Area seepage basins remediation project are expected to be subjected to somewhat different conditions (e.g. considerably lower iron concentrations) than was the case at the test site, the potential for microbiologically mediated clogging and fouling within the process should be considered. A sampling program that includes microbiological testing is highly recommended

  17. Long-term functional improvements in the 2-year treatment of schizophrenia outpatients with olanzapine long-acting injection

    Directory of Open Access Journals (Sweden)

    Ascher-Svanum H

    2014-06-01

    Full Text Available Haya Ascher-Svanum,1 Diego Novick,2,3 Josep Maria Haro,4 Jordan Bertsch,4 David McDonnell,1 Holland Detke11Eli Lilly and Company, Indianapolis, IN, USA; 2Eli Lilly and Company, Windlesham, Surrey, UK; 3Departament de Psiquiatria, Universitat Autonoma de Barcelona, Spain; 4Parc Sanitari Sant Joan de Déu, Centro de Investigación Biomédica en Red en el Área de Salud Mental, Universitat de Barcelona, Barcelona, SpainBackground: Little is known about the long-term changes in the functioning of schizophrenia patients receiving maintenance therapy with olanzapine long-acting injection (LAI, and whether observed changes differ from those seen with oral olanzapine.Methods: This study describes changes in the levels of functioning among outpatients with schizophrenia treated with olanzapine-LAI compared with oral olanzapine over 2 years. This was a secondary analysis of data from a multicenter, randomized, open-label, 2-year study comparing the long-term treatment effectiveness of monthly olanzapine-LAI (405 mg/4 weeks; n=264 with daily oral olanzapine (10 mg/day; n=260. Levels of functioning were assessed with the Heinrichs–Carpenter Quality of Life Scale. Functional status was also classified as “good”, “moderate”, or “poor”, using a previous data-driven approach. Changes in functional levels were assessed with McNemar’s test and comparisons between olanzapine-LAI and oral olanzapine employed the Student’s t-test. Results: Over the 2-year study, the patients treated with olanzapine-LAI improved their level of functioning (per Quality of Life total score from 64.0–70.8 (P<0.001. Patients on oral ­olanzapine also increased their level of functioning from 62.1–70.1 (P<0.001. At baseline, 19.2% of the olanzapine-LAI-treated patients had a “good” level of functioning, which increased to 27.5% (P<0.05. The figures for oral olanzapine were 14.2% and 24.5%, respectively (P<0.001. Results did not significantly differ between

  18. Interpretation and modeling of a subsurface injection test, 200 East Area, Hanford, Washington

    International Nuclear Information System (INIS)

    Smoot, J.L.; Lu, A.H.

    1994-11-01

    A tracer experiment was conducted in 1980 and 1981 in the unsaturated zone in the southeast portion of the Hanford 200 East Area near the Plutonium-Uranium Extraction (PUREX) facility. The field design consisted of a central injection well with 32 monitoring wells within an 8-m radius. Water containing radioactive and other tracers was injected weekly during the experiment. The unique features of the experiment were the documented control of the inputs, the experiment's three-dimensional nature, the in-situ measurement of radioactive tracers, and the use of multiple injections. The spacing of the test wells provided reasonable lag distribution for spatial correlation analysis. Preliminary analyses indicated spatial correlation on the order of 400 to 500 cm in the vertical direction. Previous researchers found that two-dimensional axisymmetric modeling of moisture content generally underpredicts lateral spreading and overpredicts vertical movement of the injected water. Incorporation of anisotropic hydraulic properties resulted in the best model predictions. Three-dimensional modeling incorporated the geologic heterogeneity of discontinuous layers and lenses of sediment apparent in the site geology. Model results were compared statistically with measured experimental data and indicate reasonably good agreement with vertical and lateral field moisture distributions

  19. Pressure and pressure derivative analysis for injection tests with variable temperature without type-curve matching

    International Nuclear Information System (INIS)

    Escobar, Freddy Humberto; Martinez, Javier Andres; Montealegre Matilde

    2008-01-01

    The analysis of injection tests under nonisothermic conditions is important for the accurate estimation of the reservoir permeability and the well's skin factor; since previously an isothermical system was assumed without taking into account a moving temperature front which expands with time plus the consequent changes in both viscosity and mobility between the cold and the hot zone of the reservoir which leads to unreliable estimation of the reservoir and well parameters. To construct the solution an analytical approach presented by Boughrara and Peres (2007) was used. That solution was initially introduced for the calculation of the injection pressure in an isothermic system. It was later modified by Boughrara and Reynolds (2007) to consider a system with variable temperature in vertical wells. In this work, the pressure response was obtained by numerical solution of the anisothermical model using the Gauss Quadrature method to solve the integrals, and assuming that both injection and reservoir temperatures were kept constant during the injection process and the water saturation is uniform throughout the reservoir. For interpretation purposes, a technique based upon the unique features of the pressure and pressure derivative curves were used without employing type-curve matching (TDS technique). The formulation was verified by its application to field and synthetic examples. As expected, increasing reservoir temperature causes a decrement in the mobility ratio, then estimation of reservoir permeability is some less accurate from the second radial flow, especially, as the mobility ratio increases

  20. INTRAARTICULAR INJECTION OF HYALURONIC ACID AFTER ARTHROSCOPIC LAVAGE OF THE KNEE: LONG-TERM RESULTS

    Directory of Open Access Journals (Sweden)

    Lidia Vladimirovna Luchikhina

    2013-01-01

    Full Text Available Objective: to evaluate the efficiency of arthroscopic lavage in combination with subsequent injection of hyaluronic acid into the joint cavity at shortand long-term follow-ups. Subjects and methods. Eighty-two patients with knee osteoarthrosis (OA were examined in accordance with the American College of Rheumatology criteria. Group 1 consisted of 40 patients only after arthroscopic lavage; Group 2 comprised 42 patients who were administered hyaluronic acid after arthroscopic lavage. Clinical evaluation encompassed pain while walking, resting, and moving (by a visual analogue scale, limited ability in covering 100 m (by a 5-point scale, general clinical evaluation (by a 5-point ordinal scale, the presence or absence of pain after 100-m walking, as well as resting pain (its presence or absence. Results. The treatment effect evaluated using different indicators was comparably positive in both groups within 3 months. Following 3 months of therapy, its effect remained stable and even better in Group 2. The latter showed a particularly noticeable superiority a year later. Thus, there were excellent and good results in 88 and 47.5% in Groups 2 and 1, respectively. The clinical symptoms of the disease were absent in 58% in Group 2 and in only 15% in Group 1. Moreover, Group 1 showed worsening and 20% of the patients had no effect. This trend was also seen while evaluating the therapeutic effectiveness in different periods. Thus, after therapy, no substantial difference was found in both groups, but 3 months later this difference was as many as 0.8 scores and a year later Group 2 had many points in its favor (1.2 scores. Conclusion. Arthroscopic lavage followed by the administration of hyaluronic acid makes it possible to prevent the negative effect of a washing liquid on the metabolism and structure of the articular cartilage and to achieve a long-term effect against the major clinical symptoms (joint pain and function affecting the quality of life. The

  1. A fast alternative to core plug tests for optimising injection water salinity for EOR

    DEFF Research Database (Denmark)

    Hassenkam, Tue; Andersson, Martin Peter; Hilner, Emelie Kristin Margareta

    2014-01-01

    of the clays which would lead to permanent reservoir damage but evidence of effectiveness at moderate salinity would offer the opportunity to dispose of produced water. The goal is to define boundary conditions so injection water salinity is high enough to prevent reservoir damage and low enough to induce...... the low salinity effect while keeping costs and operational requirements at a minimum. Traditional core plug testing for optimising conditions has some limitations. Each test requires a fresh sample, core testing requires sophisticated and expensive equipment, and reliable core test data requires several...... experiments can be done relatively quickly on very little material, it gives the possibility of testing salinity response on samples from throughout a reservoir and for gathering statistics. Our approach provides a range of data that can be used to screen core plug testing conditions and to provide extra data...

  2. Surface self-potential patterns related to transmissive fracture trends during a water injection test

    Science.gov (United States)

    DesRoches, A. J.; Butler, K. E.; MacQuarrie, K. TB

    2018-03-01

    Variations in self-potential (SP) signals were recorded over an electrode array during a constant head injection test in a fractured bedrock aquifer. Water was injected into a 2.2 m interval isolated between two inflatable packers at 44 m depth in a vertical well. Negative SP responses were recorded on surface corresponding to the start of the injection period with strongest magnitudes recorded in electrodes nearest the well. SP response decreased in magnitude at electrodes further from the well. Deflation of the packer system resulted in a strong reversal in the SP signal. Anomalous SP patterns observed at surface at steady state were found to be aligned with dominant fracture strike orientations found within the test interval. Numerical modelling of fluid and current flow within a simplified fracture network showed that azimuthal patterns in SP are mainly controlled by transmissive fracture orientations. The strongest SP gradients occur parallel to hydraulic gradients associated with water flowing out of the transmissive fractures into the tighter matrix and other less permeable cross-cutting fractures. Sensitivity studies indicate that increasing fracture frequency near the well increases the SP magnitude and enhances the SP anomaly parallel to the transmissive set. Decreasing the length of the transmissive fractures leads to more fluid flow into the matrix and into cross-cutting fractures proximal to the well, resulting in a more circular and higher magnitude SP anomaly. Results from the field experiment and modelling provide evidence that surface-based SP monitoring during constant head injection tests has the ability to identify groundwater flow pathways within a fractured bedrock aquifer.

  3. [Application of injection test in confirming the ideal position of esophageal balloon catheter].

    Science.gov (United States)

    Chen, Han; Xu, Ming; Yang, Yanlin; He, Xuan; Zhou, Jianxin

    2017-09-01

    To evaluate the safety and feasibility of injection test which is used to locate esophageal balloon catheter. A prospective study was conducted. The patients undergoing invasive mechanical ventilation (MV) admitted to general intensive care unit (ICU) of Beijing Tiantan Hospital Affiliated to Capital Medical University from May 2015 and March 2017 were enrolled. The commercially available esophageal balloon catheter was modified to perform injection test. The catheter was withdrawn step by step and the injection test was repeated until the presence disturbance wave presented, which indicated that the balloon had just entered the esophagus. The position where disturbance wave appears was named 0 cm. End-expiratory occlusions were performed at the positions of +15, +10, +5, 0, -5, -10 and -15 cm, respectively, and the changes of esophageal pressure (Pes) and airway pressures (Paw) were measured in the spontaneous breathing and passive ventilation, and the ratio between the changes (ΔPes/ΔPaw) was calculated. A total of 20 patients were enrolled, of which 15 patients finished both the spontaneous and the passive ventilation parts, and 2 patients finished only the spontaneous part and 3 patients finished only passive part. (1) Disturbance waves could be induced by injection test in all patients. The average depth of disturbance wave in spontaneous breathing was deeper than that in passive ventilation (cm: 42.4±3.8 vs. 41.8±3.3), but there was no significant difference between the two ventilation settings (P = 0.132). No adverse events occurred during the study period. (2) Pes increased with the stepwise withdraw of esophageal catheter, reached the maximal value at +5 cm, and then decreased when the catheter was further withdrawn, no matter in the spontaneous or the passive ventilation. In spontaneous breathing, the ΔPes/ΔPaw was within the ideal range (0.8-1.2) at the positions of 0, -5 and -10 cm. The ΔPes/ΔPaw was closest to unity at the positions of 0 cm (0

  4. Impact of iodized oil injection during pregnancy on thyroid function tests of offspring

    International Nuclear Information System (INIS)

    Saadat, N.; Sheikholeslam, R.; Azizi, F.

    2002-01-01

    Previous studies have shown that injection of iodized oil in pregnant women can be used as a prophylactic strategy for iodine deficiency disorders and may improve the growth indices of their offspring. Since administration of pharmacological doses of iodine may lead occasionally to large goiter and rarely to hypothyroidism, in the present study the thyroid function tests of neonates and infants born to women who had received 480 mg iodized oil intramuscularly during pregnancy were assessed and compared to those of a control group. Off 277 cord blood samples obtained from Mazandaran and Khohkiluyeh-Boyerahmad provinces, 125 made up the case (injected) and 152 the control (non-injected) group. Of 1026 blood samples of the neonates and infants from Mazandaran province. 544 made up the case and 482 the control group. Serum T 4 , T 3 and TSH concentrations were measured with RIA kits. in the cord blood samples, mean serum T 4 in cases who had received iodized oil was lower than that of the control group:140± 32 vs. 149± 33 nmol/L, respectively; p 3 and TSH were not however different. In the neonates and infants, T 4 and T 3 concentrations were significantly higher in the case than control group:178± 40 vs. 168± and 3.5±0,02 nmol/L, respectively, both p 3 and decreased TSH were seen in infants of mothers who were injected in the second and third trimesters of pregnancy. Injection of iodized oil in pregnant women does not cause hypothyroidism in the offsprings, however it does cause a transient increase in serum thyroid hormones and a decrease in TSH concentrations

  5. In Situ Redox Manipulation Field Injection Test Report - Hanford 100-H Area

    International Nuclear Information System (INIS)

    Fruchter, J.S.; Amonette, J.E.; Cole, C.R.

    1996-11-01

    This report presents results of an In Situ Redox Manipulation (ISRM) Field Injection Withdrawal Test performed at the 100-H Area of the US. Department of Energy's (DOE's) Hanford Site in Washington State in Fiscal Year 1996 by researchers at Pacific Northwest National Laboratory (PNNL). The test is part of the overall ISRM project, the purpose of which is to determine the potential for remediating contaminated groundwater with a technology based on in situ manipulation of subsurface reduction-oxidation (redox) conditions. The ISRM technology would be used to treat subsurface contaminants in groundwater zones at DOE sites

  6. people who inject drugs, HIV risk, and HIV testing uptake in sub-Saharan Africa.

    Science.gov (United States)

    Asher, Alice K; Hahn, Judith A; Couture, Marie-Claude; Maher, Kelsey; Page, Kimberly

    2013-01-01

    Dramatic rises in injection drug use (IDU) in sub-Saharan Africa account for increasingly more infections in a region already overwhelmed by the HIV epidemic. There is no known estimate of the number of people who inject drugs (PWID) in the region, or the associated HIV prevalence in PWID. We reviewed literature with the goal of describing high-risk practices and exposures in PWID in sub-Saharan Africa, as well as current HIV prevention activities aimed at drug use. The literature search looked for articles related to HIV risk, injection drug users, stigma, and HIV testing in sub-Saharan Africa. This review found evidence demonstrating high rates of HIV in IDU populations in sub-Saharan Africa, high-risk behaviors of the populations, lack of knowledge regarding HIV, and low HIV testing uptake. There is an urgent need for action to address IDU in order to maintain recent decreases in the spread of HIV in sub-Saharan Africa. Copyright © 2013 Association of Nurses in AIDS Care. Published by Elsevier Inc. All rights reserved.

  7. EXPERIMENTAL TARGET INJECTION AND TRACKING SYSTEM CONSTRUCTION AND SINGLE SHOT TESTING

    International Nuclear Information System (INIS)

    PETZOLDT, R.W.; ALEXANDER, N.B.; DRAKE, T.J.; GOODIN, D.T; JONESTRACK, K; VERMILLION, B.A

    2003-01-01

    Targets must be injected into an IFE power plant at a rate of approximately 5 to 10 Hz. Targets must be tracked very accurately to allow driver beams to be aligned with defined points on the targets with accuracy ± 150 (micro)m for indirect drive and ± 20 (micro)m for direct drive. An experimental target injection and tracking system has been constructed at General Atomics. The injector system will be used as a tool for testing the survivability of various target designs and provide feedback to the target designers. Helium gas propels the targets down an 8 m gun barrel up to 400 m/s. Direct-drive targets are protected in the barrel by sabots that are spring loaded to separate into two halves after acceleration. A sabot deflector directs the sabot halves away from the target injection path. Targets will be optically tracked with laser beams and line-scan cameras. Target position and arrival time will be predicted in real time based on early target position measurements. The system installation will be described. System testing to overcome excessive projectile wear and debris in the gun barrel is presented

  8. Do cervical epidural injections provide long-term relief in neck and upper extremity pain? A systematic review.

    Science.gov (United States)

    Manchikanti, Laxmaiah; Nampiaparampil, Devi E; Candido, Kenneth D; Bakshi, Sanjay; Grider, Jay S; Falco, Frank J E; Sehgal, Nalini; Hirsch, Joshua A

    2015-01-01

    The high prevalence of chronic persistent neck pain not only leads to disability but also has a significant economic, societal, and health impact. Among multiple modalities of treatments prescribed in the management of neck and upper extremity pain, surgical, interventional and conservative modalities have been described. Cervical epidural injections are also common modalities of treatments provided in managing neck and upper extremity pain. They are administered by either an interlaminar approach or transforaminal approach. To determine the long-term efficacy of cervical interlaminar and transforaminal epidural injections in the treatment of cervical disc herniation, spinal stenosis, discogenic pain without facet joint pain, and post surgery syndrome. The literature search was performed from 1966 to October 2014 utilizing data from PubMed, Cochrane Library, US National Guideline Clearinghouse, previous systematic reviews, and cross-references. The evidence was assessed based on best evidence synthesis with Level I to Level V. There were 7 manuscripts meeting inclusion criteria. Of these, 4 assessed the role of interlaminar epidural injections for managing disc herniation or radiculitis, and 3 assessed these injections for managing central spinal stenosis, discogenic pain without facet joint pain, and post surgery syndrome. There were 4 high quality manuscripts. A qualitative synthesis of evidence showed there is Level II evidence for each etiology category. The evidence is based on one relevant, high quality trial supporting the efficacy of cervical interlaminar epidural injections for each particular etiology. There were no randomized trials available assessing the efficacy of cervical transforaminal epidural injections. Paucity of available literature, specifically conditions other than disc herniation. This systematic review with qualitative best evidence synthesis shows Level II evidence for the efficacy of cervical interlaminar epidural injections with local

  9. Large scale gas injection test (Lasgit) performed at the Aespoe Hard Rock Laboratory. Summary report 2008

    International Nuclear Information System (INIS)

    Cuss, R.J.; Harrington, J.F.; Noy, D.J.

    2010-02-01

    This report describes the set-up, operation and observations from the first 1,385 days (3.8 years) of the large scale gas injection test (Lasgit) experiment conducted at the Aespoe Hard Rock Laboratory. During this time the bentonite buffer has been artificially hydrated and has given new insight into the evolution of the buffer. After 2 years (849 days) of artificial hydration a canister filter was identified to perform a series of hydraulic and gas tests, a period that lasted 268 days. The results from the gas test showed that the full-scale bentonite buffer behaved in a similar way to previous laboratory experiments. This confirms the up-scaling of laboratory observations with the addition of considerable information on the stress responses throughout the deposition hole. During the gas testing stage, the buffer was continued to artificially hydrate. Hydraulic results, from controlled and uncontrolled events, show that the buffer continues to mature and has yet to reach full maturation. Lasgit has yielded high quality data relating to the hydration of the bentonite and the evolution in hydrogeological properties adjacent to the deposition hole. The initial hydraulic and gas injection tests confirm the correct working of all control and data acquisition systems. Lasgit has been in successful operation for in excess of 1,385 days

  10. Large scale gas injection test (Lasgit) performed at the Aespoe Hard Rock Laboratory. Summary report 2008

    Energy Technology Data Exchange (ETDEWEB)

    Cuss, R.J.; Harrington, J.F.; Noy, D.J. (British Geological Survey (United Kingdom))

    2010-02-15

    This report describes the set-up, operation and observations from the first 1,385 days (3.8 years) of the large scale gas injection test (Lasgit) experiment conducted at the Aespoe Hard Rock Laboratory. During this time the bentonite buffer has been artificially hydrated and has given new insight into the evolution of the buffer. After 2 years (849 days) of artificial hydration a canister filter was identified to perform a series of hydraulic and gas tests, a period that lasted 268 days. The results from the gas test showed that the full-scale bentonite buffer behaved in a similar way to previous laboratory experiments. This confirms the up-scaling of laboratory observations with the addition of considerable information on the stress responses throughout the deposition hole. During the gas testing stage, the buffer was continued to artificially hydrate. Hydraulic results, from controlled and uncontrolled events, show that the buffer continues to mature and has yet to reach full maturation. Lasgit has yielded high quality data relating to the hydration of the bentonite and the evolution in hydrogeological properties adjacent to the deposition hole. The initial hydraulic and gas injection tests confirm the correct working of all control and data acquisition systems. Lasgit has been in successful operation for in excess of 1,385 days

  11. Automatic monitoring of radial injection tracer tests using a novel multi-electrode resistivity system

    International Nuclear Information System (INIS)

    Ward, R.S.; Sen, M.A.; Williams, G.M.; Jackson, P.D.

    1990-01-01

    A radial injection tracer test has been carried out in an unconfined fluvial sand and gravel aquifer underlain by low permeability clay. Sodium chloride has been used as an electrolyte tracer and breakthrough has been monitored using a newly developed automatic resistivity system (RESCAN) incorporating six fully penetrating resistivity probes each having 80 electrodes spaced at 5 cm intervals along their length. Each electrode is individually addressable under computer control to either carry current or measure potential. Any four electrodes can be selected in the traditional Wenner configuration to measure formation resistivity. Rapid measurement of changes in resistivity allows a very detailed picture of tracer migration to be obtained. The resistivity probes were placed at 1 and 2 m radii from the central fully-screened tracer injection well along three limbs at 120 degrees. Resistivity measurements were compared with adjacent multi-level samplers. An 8 x 8 m grid of 140 surface electrodes centred on the central well was also installed. The resistivity profiles measured prior to tracer injection were used to infer lithology, particularly layering. Detailed breakthrough curves were obtained at 77 positions along each of the six probes and compared with adjacent multi-level sampler breakthrough curves. The results showed that the aquifer was extremely heterogeneous even on this small scale. Because the system operates automatically without the need to extract and analyse large numbers of water samples, it opens up the possibility of carrying out lots of small scale injection tests within a larger domain likely to be invaded by a tracer or pollution plume. Such detailed information for determining aquifer properties can provide the data set necessary for characterisation of the aquifer to predict dispersion parameters appropriate to the large scale. (Author) (6 refs., 9 figs., 2 tabs.)

  12. Long-term complications of polyethylene glycol injection to the face.

    Science.gov (United States)

    Altintas, Hande; Odemis, Mustafa; Bilgi, Selcuk; Cakmak, Ozcan

    2012-04-01

    Currently, filling, smoothing, or recontouring the face through the use of injectable fillers is one of the most popular forms of cosmetic surgery. Because these materials promise a more youthful appearance without anesthesia in a noninvasive way, various fillers have been used widely in different parts of the world. However, most of these fillers have not been approved by the Food and Drug Administration, and their applications might cause unpleasant disfiguring complications. This report describes a case of foreign body granuloma in the cheeks secondary to polyethylene glycol injection and shows the possible complications associated with the use of facial fillers.

  13. Experimental results of the SMART ECC injection performance with reduced scale of test facility

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Young Il; Cho, Seok; Ko, Yung Joo; Shin, Yong Cheol; Kwon, Tae Soon [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2011-05-15

    SMART pressurized water reactor type is different from the existing integral NSSS commercial pressurized water reactor system which is equipped with the main features. In addition, RCS piping is removed and the feature of the SBLOCA is a major design break accident. SWAT (SMART ECC Water Asymmetric Two-phase choking test facility) test facility is to simulate the 2 inch SBLOCA of the SMART using with reduced scale. The Test was performed to produce experimental data for the validation of the TASS/SMR-S thermal hydraulic analysis code, and to investigate the related thermal hydraulic phenomena in the down-comer region during the 2 inch SBLOCA of the safety inject line. The particular phenomena for the observation are ECC bypass and multi-dimensional flow characteristics to verify the effectiveness and performance of the safety injection system. In this paper, the corresponding steady state test conditions, including initial and boundary conditions along with major measuring parameters, and related experimental results were described

  14. Experiences with urine drug testing by police among people who inject drugs in Bangkok, Thailand.

    Science.gov (United States)

    Hayashi, Kanna; Ti, Lianping; Buxton, Jane A; Kaplan, Karyn; Suwannawong, Paisan; Wood, Evan; Kerr, Thomas

    2014-03-01

    Thailand has relied on drug law enforcement in an effort to curb illicit drug use. While anecdotal reports suggest that Thai police frequently use urine toxicology to identify drug users, little is known about the prevalence or impacts of this practice among people who inject drugs (IDU). Therefore, we sought to examine experiences with urine drug testing by police among IDU in Bangkok. Data were derived from a community-recruited sample of IDU in Bangkok participating in the Mitsampan Community Research Project between July and October 2011. We assessed the prevalence and correlates of being subjected to urine toxicology testing by police using multivariate Poisson regression. In total, 438 IDU participated in this study, with 293 (66.9%) participants reporting having been tested for illicit drugs by police. In multivariate analyses, reports of drug testing by police were independently and positively associated with younger age (adjusted prevalence ratio [APR]: 1.28), a history of methamphetamine injection (APR: 1.22), a history of incarceration (APR: 1.21), having been in compulsory drug detention (APR: 1.43), avoiding healthcare (APR: 1.15), and HIV seropositivity (APR: 1.19), and negatively associated with access to voluntary drug treatment (APR: 0.82) (all p<0.05). A high proportion of IDU in Bangkok were subjected to drug testing by police. Young people and methamphetamine injectors were more likely to have been tested. The findings indicate that drug testing by police is associated with the compulsory drug detention system and may be interfering with IDU's access to healthcare and voluntary drug treatment. These findings raise concern about the widespread practice of drug testing by police and its associated impacts. Copyright © 2013 Elsevier B.V. All rights reserved.

  15. Short- and long-term efficacy of intra-articular injections with betamethasone as part of a treat-to-target strategy in early rheumatoid arthritis

    DEFF Research Database (Denmark)

    Hetland, Merete Lund; Østergaard, Mikkel; Ejbjerg, Bo

    2012-01-01

    To investigate the short-term and long-term efficacy of intra-articular betamethasone injections, and the impact of joint area, repeated injections, MRI pathology, anticyclic citrullinated peptide (CCP) and immunoglobulin M rheumatoid factor (IgM-RF) status in patients with early rheumatoid arthr...

  16. Forecast of thermal-hydrological conditions and air injection test results of the single heater test at Yucca Mountain

    International Nuclear Information System (INIS)

    Birkholzer, J.T.; Tsang, Y.W.

    1996-12-01

    The heater in the Single Heater Test (SHT) in alcove 5 of the Exploratory Studies Facility (ESF) was turned on August 26, 1996. A large number of sensors are installed in the various instrumented boreholes to monitor the coupled thermal-hydrological-mechanical-chemical responses of the rock mass to the heat generated in the single heater. In this report the authors present the results of the modeling of both the heating and cooling phases of the Single Heater Test (SHT), with focus on the thermal-hydrological aspect of the coupled processes. Also in this report, the authors present simulations of air injection tests will be performed at different stages of the heating and cooling phase of the SHT

  17. Flow-injection system for automated dissolution testing of isoniazid tablets with chemiluminescence detection.

    Science.gov (United States)

    Li, B; Zhang, Z; Liu, W

    2001-05-30

    A simple and sensitive flow-injection chemiluminescence (CL) system for automated dissolution testing is described and evaluated for monitoring of dissolution profiles of isoniazid tablets. The undissolved suspended particles in the dissolved solution were eliminated via on-line filter. The novel CL system of KIO(4)-isoniazid was also investigated. The sampling frequency of the system was 120 h(-1). The dissolution profiles of isoniazid fast-release tablets from three sources were determined, which demonstrates the stability, great sensitivity, large dynamic measuring range and robustness of the system.

  18. Short Term Analgesic Effects of 5% Dextrose Epidural Injections for Chronic Low Back Pain: A Randomized Controlled Trial.

    Science.gov (United States)

    Maniquis-Smigel, Liza; Dean Reeves, Kenneth; Jeffrey Rosen, Howard; Lyftogt, John; Graham-Coleman, Cassie; Cheng, An-Lin; Rabago, David

    2017-02-01

    Hypertonic dextrose injection (prolotherapy) is reported to reduce pain including non-surgical chronic low back pain (CLBP), and subcutaneous injection of 5% dextrose is reported to reduce neurogenic pain, hyperalgesia and allodynia. The mechanism in both cases is unclear, though a direct effect of dextrose on neurogenic pain has been proposed. This study assessed the short-term analgesic effects of epidural 5% dextrose injection compared with saline for non-surgical CLBP. Randomized double-blind (injector, participant) controlled trial. Adults with moderate-to-severe non-surgical low back pain with radiation to gluteal or leg areas for at least 6 months received a single epidurogram-confirmed epidural injection of 10 mL of 5% dextrose or 0.9% saline using a published vertical caudal injection technique. The primary outcome was change in a numerical rating scale (NRS, 0 - 10 points) pain score between baseline and 15 minutes; and 2, 4, and 48 hours and 2 weeks post-injection. The secondary outcome was percentage of participants achieving 50% or more pain improvement at 4 hours. No baseline differences existed between groups; 35 participants (54 ± 10.7 years old; 11 female) with moderate-to-severe CLBP (6.7 ± 1.3 points) for 10.6 ± 10.5 years. Dextrose participants reported greater NRS pain score change at 15 minutes (4.4 ± 1.7 vs 2.4 ± 2.8 points; P = 0.015), 2 hours (4.6 ± 1.9 vs 1.8 ± 2.8 points; P = 0.001), 4 hours (4.6 ± 2.0 vs 1.4 ± 2.3 points; P dextrose recipients and 19% (3/16) of saline recipients reported ≥ 50% pain reduction at 4 hours (P dextrose on pain at the dorsal root level; waning pain control at 2 weeks suggests the need to assess the effect of serial dextrose epidural injections in a long-term study with robust outcome assessment.

  19. A New Sacroiliac Joint Injection Technique and Its Short-Term Effect on Chronic Sacroiliac Region Pain.

    Science.gov (United States)

    Do, Kyung Hee; Ahn, Sang Ho; Jones, Rodney; Jang, Sung Ho; Son, Su Min; Lee, Dong Gyu; Cho, Hee Kyung; Choi, Gyu Sik; Cho, Yun-Woo

    2016-10-01

    Sacroiliac joint (SIJ) injections have been used to provide short-term relief of SIJ pain. In this study, the authors investigated a new technique using a superior approach. Twenty four patients with chronic SI joint paint were recruited. Each patient was treated with a single SIJ intra-articular injection plus a periarticular injection of local anesthetic and corticosteroid in one procedure. Technical accuracy of the intra-articular procedure was determined by having 2 independent observers review and rate the quality of arthrograms obtained. Treatment effects were evaluated using a numerical rating scale, the Oswestry disability index (ODI) and global perceived effect (GPE). Both independent observers agreed that satisfactory arthrograms were obtained in all patients. Pain scores and disability were significantly reduced at 2 weeks and 4 weeks after treatment. Nineteen patients (79%) reported satisfaction with treatment. No serious adverse effects were encountered. The superior approach consistently achieves good access to the SI joint, and achieves outcomes that are compatible with those of other techniques. The superior approach constitutes an alternative to other techniques for injections into the SI joint. © 2016 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  20. Long-term follow-up of a case of intravenous elementary mercury injection

    International Nuclear Information System (INIS)

    Walter, E.

    1986-01-01

    Elementary mercury is usually intravenously injected with suicidal intent. It is floated to the heart and lungs but is also deposited in the abdominal organs. Case histories presented in the literature so far have been followed up clinically and roentgenologically for up to three years. We report one patient attempting suicidal mercury injection, whom we were able to follow up for 10 years. It could be demonstrated that quite in contrast to former suggestions elementary mercury is dissolved and oxidised in the body. Chronic poisoning with mercury compounds causes continuing damage, particularly to the kidneys. Apart from that question, the element's pattern of spread within the body, toxicological issues, particular pathologic anatomic changes, their demonstrability on X-ray films and their clinical relevance are all discussed in this paper. (orig.) [de

  1. Dominant lethal tests of male mice given 239Pu salt injections

    International Nuclear Information System (INIS)

    Luening, K.G.; Froelen, H.; Nilsson, A.

    1976-01-01

    To study the possible genetic effects of 239 Pu manifesting in dominant lethals, five test series (E1-E5) were performed. Males from an inbred CBA strain were given 239 Pu salt injections intravenously and mated weekly to 3 CBA females each for 12 to 24 weeks. Some interruptions in the mating scheme were made. For the first two test series (E1, E2) 239 Pu nitrate solution and 239 Pu citrate, used in E3-E5, were prepared. The solution was millipore filtered just prior to injection. Among a total of 10255 implants sired by males given Pu-nitrate in E1 and E2 no significant excess of intra-uterine death relative to 7216 control implants occurred. Test series E3-E5 with 60 males each, used three groups of 20, with one control group. In E3, 0.5 μCi and 0.1 μCi were given per male/group, respectively; in E4 and E5, 0.25 μCi and 0.05 μCi, respectively. The males given 0.5 μCi in E3 became successively sterile from the 7th week. The results in E3-E5 point in the same direction with significant excess of intra-uterine death in E3 and E5. In E4 the females from matings from the 9th, 14th and 16th week, and in E5 females from the 9th week, were allowed to litter to give F 1 offspring. Dominant lethal tests of F 1 males gave concordant results in all four samples, showing significantly excessive death in offspring to F 1 males whose fathers had received Pu. The excessive death was evenly distributed and did not indicate the presence of semisterile F 1 males. In tests of Pu-injected males and of F 1 males a remarkable excess of death in late stages of foetal development was observed. Such effects had never before been observed in this CBA strain in tests of extrinsic and intrinsic exposure to ionizing irradiation

  2. Risperidone long-acting injection: a review of its long term safety and efficacy

    Directory of Open Access Journals (Sweden)

    Michael K Rainer

    2008-08-01

    Full Text Available Michael K RainerMemory-Clinic and Psychiatric Department, Donauspital, Vienna, AustriaAbstract: A long-acting form of the second-generation antipsychotic drug risperidone is now broadly available for the treatment of schizophrenia and closely related psychiatric conditions. It combines the advantage of previously available depot formulations for first-generation drugs with the favorable characteristics of the modern “atypical” antipsychotics, namely higher efficacy in the treatment of the negative symptoms of schizophrenia and reduced motor disturbances. Published clinical studies show an objective clinical efficacy (as per psychiatric symptom scores and relapse data that exceeds that of oral atypical antipsychotics when patients are switched to the long-acting injectable form, a low incidence of treatment-emergent extrapyramidal side effects, and very good acceptance by patients. Available data for maintenance treatment of bipolar disorder show equivalence with the oral form instead of superiority, but are still limited. As it seems likely that efficacy benefits are mostly due to the fact that the injectable form reduces the demand for patient compliance to one physician visit every 2 weeks instead of self-administration on a daily or twice-daily basis, additional potential could exist in other psychiatric disorders where atypical antipsychotic drugs are of benefit but where patient adherence to treatment schedules is typically low.Keywords: risperidone, schizophrenia, psychotic disorders, patient compliance; delayed-action preparations, injections, intramuscular

  3. Results of full scale dry injection tests at MSW-incinerators using a new active absorbent

    International Nuclear Information System (INIS)

    Felsvang, K.S.; Helvind, O.

    1991-01-01

    Worldwide incineration of municipal solid waste (MSW) has been utilized to reduce the volume of waste to be disposed of. Increasing environmental concerns over the potential air pollution impacts have led to emission limits for pollutants such as HCl, SO 2 , particulate, and more recently also for mercury and dioxins. For a certain size of incinerators, dry sorbent injection is the preferred technology for air pollution control. This paper describes the development of a new active sorbent, Scansorb, which is particularly suited for use in dry injection processes. The new sorbent is a lime based product with adjustable properties. Scansorb can be produced with a specific surface area of 30 to 100 m 2 /g. Pilot plant development work has shown that a considerable reduction in the absorbent quantity can be achieved when Scansorb is used instead of commercial hydrated lime. Full scale tests performed at four different MSW incinerators have confirmed the viability of the new active absorbent. The full scale tests have demonstrated that more than 50% SO 2 removal can be achieved with Scansorb at quantities much less than with commercial hydrated lime

  4. An evaluation of a new N-isopropyl-p-[123I] iodoamphetamine double injection method for acetazolamide testing

    International Nuclear Information System (INIS)

    Mori, Kentaro; Maeda, Minoru; Asegawa, Satoshi; Masuda, Yoko.

    1994-01-01

    To evaluate the capacity of the cerebrovascular reserve, the acetazolamide test must be used to quantitatively measure the cerebral blood flow (CBF) before and after the administration of acetazolamide. Previously, the authors have explained the rationale for using 5 min SPECT images to quantify the CBF with N-isoprophyl-p-[ 123 I] iodoamphetamine ( 123 I-IMP), and in this study they describe how they devised a 123 I-IMP double injection method for use with the acetazolamide test, and report on the clinical results. First, We measured the brain and arterial 123 I concentrations 10 normal subjects after a 123 I-IMP injection, and noted that after 25 minutes the brain and arterial blood activity had plateaued and stabilized. Thus, by using the background substraction method, We found it possible to quantitatively measure the CBF twice in 30 minutes and have called this technique the double injection method. We have clinically used this double injection method for evaluating the CBF in 5 lacunar stroke patients with no major arterial occlusion and found no statistically significant difference in the CBF values between the first and second CBF measurements. They then applied this double injection method for the acetazolamide testing of 10 stroke patients with an arterial occlusion of stenosis and found that the CBF results compared favorably with the CBF results achieved with the use of the separate injection method. It also should be noted the double injection method was successfully used for clinical CBF measurements without acetazolamide testing. (author)

  5. Browns Ferry Nuclear Plant: variation in test intervals for high-pressure coolant injection (HPCI) system

    International Nuclear Information System (INIS)

    Christie, R.F.; Stetkar, J.W.

    1985-01-01

    The change in availability of the high-pressure coolant injection system (HPCIS) due to a change in pump and valve test interval from monthly to quarterly was analyzed. This analysis started by using the HPCIS base line evaluation produced as part of the Browns Ferry Nuclear Plant (BFN) Probabilistic Risk Assessment (PRA). The base line evaluation showed that the dominant contributors to the unavailability of the HPCI system are hardware failures and the resultant downtime for unscheduled maintenance. The effect of changing the pump and valve test interval from monthly to quarterly was analyzed by considering the system unavailability due to hardware failures, the unavailability due to testing, and the unavailability due to human errors that potentially could occur during testing. The magnitude of the changes in unavailability affected by the change in test interval are discussed. The analysis showed a small increase in the availability of the HPCIS to respond to loss of coolant accidents (LOCAs) and a small decrease in the availability of the HPCIS to respond to transients which require HPCIS actuation. In summary, the increase in test interval from monthly to quarterly does not significantly impact the overall HPCIS availability

  6. Long-term follow-up of ultrasound-guided botulinum toxin-A injections for sialorrhea in neurological dysphagia.

    Science.gov (United States)

    Barbero, Pierangelo; Busso, Marco; Tinivella, Marco; Artusi, Carlo Alberto; De Mercanti, Stefania; Cucci, Angele; Veltri, Andrea; Avagnina, Paolo; Calvo, Andrea; Chio', Adriano; Durelli, Luca; Clerico, Marinella

    2015-12-01

    Literature provides reports only of a limited follow-up single injection of botulinum toxin-A (BoNT-A) in patients with sialorrhea. The aim of our study is to evaluate the long-lasting efficacy and safety of ultrasound-guided BoNT-A injections for severe sialorrhea secondary to neurological dysphagia. We enrolled 38 severe adult sialorrhea patients referred consecutively to the neurology unit and performed bilateral parotid and submandibular gland BoNT-A injections under ultrasound guidance. The outcomes of the study were reduction of sialorrhea, duration of therapeutic effect, and subjective patient- and caregiver-reported satisfaction. A total of 113 BoNT-A administrations were given during the study period with a mean duration of follow-up of 20.2 ± 4.4 months. We observed a significant decrease from baseline in mean number of daily aspirations and a significant improvement in patient- and caregiver-reported outcomes following ultrasound-guided BoNT-A injections (p < 0.001 vs baseline for all comparisons) and the mean duration of the efficacy was 5.6 ± 1 months. No major treatment-related adverse events occurred and a low incidence of minor adverse events was reported. This study confirms the long-lasting efficacy and safety of ultrasound-guided BoNT-A injections for sialorrhea, regardless of the causative neurological disorder. These results should encourage the use of BoNT-A in the treatment of severe sialorrhea and highlight the role of ultrasound guidance to obtain optimal results in terms of safety and reproducible outcomes.

  7. Percutaneous ethanol injection therapy (PEIT) for small hepatocellular carcinomas (HCCs) : prognostic factors affecting short-term follow-up results

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ah Young; Han, Joon Koo; Kim, Tae Kyoung; Yun, Eun Joo; Lee, Ki Yeol; Choi, Byung Ihn [Seoul National Univ. (Korea, Republic of). Coll. of Medicine

    1998-06-01

    The purpose of this study is to analyze the effect of various parameters used in PEIT on the short-term results of this procedure for the treatment of small HCC. Among 76 lesions in 63 patients with HCCs, 66 were diagnosed by tissue biopsy (n=30) or according to clinical features, tumor marker, and the results of angiography and other diagnostic imagings (n=36). These patients underwent PEIT between November 1993 and October 1996; the indications for PEIT were nodular lesions less than 3 cm in size, less than three in number, and unsuitable for surgical resection or transcatheter arterial chemoembolization therapy. The effect of PEIT was evaluated by two phase spiral CT one month later (64 lesions) or by serial ultrasound for 6 months. We analyzed and graded the short-term effect of PEIT on HCCs as complete remission (CR), partial remission (PR) or no change/aggravation (NC/AG). We also evaluated the correlation between the short-term results of PEIT and variable parameters such as size of the lesion, frequency of PEI per session, child classification of the patient, the ratio of amount of injected ethanol per volume of the lesion, and {alpha}-fetoprotein level before the procedure. The therapeutic effect of PEIT was CR in 45 lesions (59.2%), PR in 18 (23.7%) and NC/AG in 13 (17.1%). The size of the tumor, child-pugh class, number of injections per session and ratio of injected volume of ethanol to tumor volume were factors affecting the therapeutic result (p < 0.05). Sufficient knowledge of prognostic factors affecting the short-term results of PEIT might help improve the effects of therapy in patients its small HCCs. (author). 19 refs., 6 figs.

  8. Injection grout for deep repositories - Low-pH cementitious grout for larger fractures. Field testing in Finland, Pilot tests

    International Nuclear Information System (INIS)

    Sievaeen, U.; Syrjaenen, P.; Ranta-aho, S.

    2005-10-01

    Posiva, SKB and NUMO have cooperated for developing a low pH injection grout for sealing of the deep repositories for spent nuclear fuel. A project 'Injection grout for deep repositories' was divided into four subprojects. The development of low pH cementitious grout for > 100 μm fractures was carried out in Finland. The development of non-cementitious low pH grout for < 100 μm fractures was carried out in Sweden. This report concerns the cementitious grout. Requirements for pH and penetration ability were set for the grouts to be developed. Besides these, the grouts were desired to fulfil certain targets set for viscosity, bleeding, shear strength, yield value, compressive strength and open time. Also durability, availability of the components and known history in practical engineering were given as requirements. The object of the work presented here was to test if the grout properties developed in laboratory can be met in field conditions. Only the most promising binder material combinations, which have fulfilled the main requirements in laboratory, were tested in field. Evaluations of environmental aspects are included in this report. In the pilot test 1, carried out in a multi-purpose tunnel in Helsinki, Portland cement-cilicasystem and blast furnace slag-based system were chosen to be tested. In field conditions, mixed with ordinary mixer, all grout properties achieved in laboratory, were not verified. Penetration ability was typically good, but fluidity and strength development were not satisfying. The main conclusion was that water to dry material ratio should be diminished. In order to get better rheological properties at the same time, superplastizicer was needed in further development of the mixes. Also accurate dosing and mixing seemed to be very important. Blast furnace slag - system was after this pilot test ruled out due to high leaching of sulphide from the product, not due to the bad technical properties. The development work continued with

  9. Sex work involvement among women with long-term opioid injection drug dependence who enter opioid agonist treatment.

    Science.gov (United States)

    Marchand, Kirsten; Oviedo-Joekes, Eugenia; Guh, Daphne; Marsh, David C; Brissette, Suzanne; Schechter, Martin T

    2012-01-25

    Substitution with opioid-agonists (e.g., methadone) has shown to be an effective treatment for chronic long-term opioid dependency. Survival sex work, very common among injection drug users, has been associated with poor Opioid Agonist Treatment (OAT) engagement, retention and response. Therefore, this study was undertaken to determine factors associated with engaging in sex work among long-term opioid dependent women receiving OAT. Data from a randomized controlled trial, the North American Opiate Medication Initiative (NAOMI), conducted in Vancouver and Montreal (Canada) between 2005-2008, was analyzed. The NAOMI study compared the effectiveness of oral methadone to injectable diacetylmorphine or injectable hydromorphone, the last two on a double blind basis, over 12 months. A research team, independent of the clinic services, obtained outcome evaluations at baseline and follow-up (3, 6, 9, 12, 18 and 24 months). A total 53.6% of women reported engaging in sex work in at least one of the research visits. At treatment initiation, women who were younger and had fewer years of education were more likely to be engaged in sex work. The multivariate logistic generalized estimating equation regression analysis determined that psychological symptoms, and high illicit heroin and cocaine use correlated with women's involvement in sex work during the study period. After entering OAT, women using injection drugs and engaging in sex work represent a particularly vulnerable group showing poorer psychological health and a higher use of heroin and cocaine compared to women not engaging in sex work. These factors must be taken into consideration in the planning and provision of OAT in order to improve treatment outcomes. NCT00175357.

  10. Sex work involvement among women with long-term opioid injection drug dependence who enter opioid agonist treatment

    Directory of Open Access Journals (Sweden)

    Marchand Kirsten

    2012-01-01

    Full Text Available Abstract Background Substitution with opioid-agonists (e.g., methadone has shown to be an effective treatment for chronic long-term opioid dependency. Survival sex work, very common among injection drug users, has been associated with poor Opioid Agonist Treatment (OAT engagement, retention and response. Therefore, this study was undertaken to determine factors associated with engaging in sex work among long-term opioid dependent women receiving OAT. Methods Data from a randomized controlled trial, the North American Opiate Medication Initiative (NAOMI, conducted in Vancouver and Montreal (Canada between 2005-2008, was analyzed. The NAOMI study compared the effectiveness of oral methadone to injectable diacetylmorphine or injectable hydromorphone, the last two on a double blind basis, over 12 months. A research team, independent of the clinic services, obtained outcome evaluations at baseline and follow-up (3, 6, 9, 12, 18 and 24 months. Results A total 53.6% of women reported engaging in sex work in at least one of the research visits. At treatment initiation, women who were younger and had fewer years of education were more likely to be engaged in sex work. The multivariate logistic generalized estimating equation regression analysis determined that psychological symptoms, and high illicit heroin and cocaine use correlated with women's involvement in sex work during the study period. Conclusions After entering OAT, women using injection drugs and engaging in sex work represent a particularly vulnerable group showing poorer psychological health and a higher use of heroin and cocaine compared to women not engaging in sex work. These factors must be taken into consideration in the planning and provision of OAT in order to improve treatment outcomes. Trial Registration NCT00175357.

  11. Client satisfaction among participants in a randomized trial comparing oral methadone and injectable diacetylmorphine for long-term opioid-dependency

    Directory of Open Access Journals (Sweden)

    Brissette Suzanne

    2011-07-01

    Full Text Available Abstract Background Substitution with opioid-agonists (e.g., methadone has shown to be an effective treatment for chronic long-term opioid dependency. Patient satisfaction with treatment has been associated with improved addiction treatment outcomes. However, there is a paucity of studies evaluating patients' satisfaction with Opioid Substitution Treatment (OST. In the present study, participants' satisfaction with OST was evaluated at 3 and 12 months. We sought to test the relationship between satisfaction and patients' characteristics, the treatment modality received and treatment outcomes. Methods Data from a randomized controlled trial, the North American Opiate Medication Initiative (NAOMI, conducted in Vancouver and Montreal (Canada between 2005-2008, was analyzed. The NAOMI study compared the effectiveness of oral methadone vs. injectable diacetylmorphine over 12 months. A small sub-group of patients received injectable hydromorphone on a double blind basis with diacetylmorphine. The Client Satisfaction Questionnaire (CSQ-8 was used to measure satisfaction with treatment. CSQ-8 scores, as well as retention and response to treatment, did not differ between those receiving hydromorphone and diacetylmorphine at 3 or 12 months assessments; therefore, these two groups were analyzed together as the 'injectable' treatment group. Results A total of 232 (92% and 237 (94% participants completed the CSQ-8 at 3 and 12 months, respectively. Participants in both groups were highly satisfied with treatment. Independent of treatment group, participants satisfied with treatment at 3 months were more likely to be retained at 12 months. Multivariate analysis indicated that satisfaction was greater among those randomized to the injection group after controlling for treatment effectiveness. Participants who were retained, responded to treatment, and had fewer psychological symptoms were more satisfied with treatment. Finally, open-ended comments were made by

  12. Single well injection withdrawal tests (SWIW) in fractured rock. Some aspects on interpretation

    International Nuclear Information System (INIS)

    Neretnieks, Ivars

    2007-08-01

    Single-Well-Injection-Withdrawal, SWIW, tests are used to try to extract information on fracture apertures, sorption and diffusion properties and dispersion information in individual fractures. It is done by injecting a given amount of traced water into an isolated fracture. After a waiting period water is withdrawn from the fracture and the tracer concentration is measured. The concentration time curve is fitted to a model and the parameter values quantifying the different interaction mechanisms are determined. A number of different mechanisms influence the recovery of the tracer. One or more of the following mechanisms are considered. They include: dispersion due to velocity differences, sorption on fracture surface and on infill, diffusion in rock fragments in the fracture, diffusion between 'streamlines', diffusion into rock matrix and other stagnant water volumes, sorption kinetics and slow drift of the plume caused by the natural gradient. Many of the interaction mechanisms can influence the recovery curve in a similar way. For example, diffusion into rock matrix water and into stagnant water in the fracture adjacent to the flowing channels cannot be distinguished if only one tracer is used. Tracers with different properties can in principle be used but they will encounter different parts of the fracture, the sorbing tracer will move out less from the injection point than a nonsorbing tracer will. Diffusion and sorption in small particles in the flowpath can influence the recovery curve in a similar way as rock matrix diffusion does. Dispersion caused by diffusion between 'streamlines', Taylor dispersion, can give very different results in channels of different shapes. Such dispersion effects can be difficult to distinguish from matrix diffusion effects. Dispersion coefficients obtained in a SWIW test may have little relation to dispersion of a tracer moving from A to B. This is partly due to the different mechanisms and partly due to different time scales

  13. Single well injection withdrawal tests (SWIW) in fractured rock. Some aspects on interpretation

    Energy Technology Data Exchange (ETDEWEB)

    Neretnieks, Ivars [Dept. of Chemical Engineering and Technology, Royal Inst. of Technology, Stockholm (Sweden)

    2007-08-15

    Single-Well-Injection-Withdrawal, SWIW, tests are used to try to extract information on fracture apertures, sorption and diffusion properties and dispersion information in individual fractures. It is done by injecting a given amount of traced water into an isolated fracture. After a waiting period water is withdrawn from the fracture and the tracer concentration is measured. The concentration time curve is fitted to a model and the parameter values quantifying the different interaction mechanisms are determined. A number of different mechanisms influence the recovery of the tracer. One or more of the following mechanisms are considered. They include: dispersion due to velocity differences, sorption on fracture surface and on infill, diffusion in rock fragments in the fracture, diffusion between 'streamlines', diffusion into rock matrix and other stagnant water volumes, sorption kinetics and slow drift of the plume caused by the natural gradient. Many of the interaction mechanisms can influence the recovery curve in a similar way. For example, diffusion into rock matrix water and into stagnant water in the fracture adjacent to the flowing channels cannot be distinguished if only one tracer is used. Tracers with different properties can in principle be used but they will encounter different parts of the fracture, the sorbing tracer will move out less from the injection point than a nonsorbing tracer will. Diffusion and sorption in small particles in the flowpath can influence the recovery curve in a similar way as rock matrix diffusion does. Dispersion caused by diffusion between 'streamlines', Taylor dispersion, can give very different results in channels of different shapes. Such dispersion effects can be difficult to distinguish from matrix diffusion effects. Dispersion coefficients obtained in a SWIW test may have little relation to dispersion of a tracer moving from A to B. This is partly due to the different mechanisms and partly due to

  14. Evaluation the short term effects on serum creatinine concentration in patients with normal renal function, mild and moderate renal insufficiency after intravenous injection of gadopentetate dimeglumine

    International Nuclear Information System (INIS)

    Luo Jian; Liu Jing; Wang Xiaoying; Yang Xuedong; Jiang Xuexiang

    2010-01-01

    Objective: To explore the effects of gadopentetate dimeglumine injection on renal function. Methods: The study included 623 consecutive patients. Their serum creatinine concentrations before and within 3 days after injection of gadopentetate dimeglumine were analyzed. Their eGFR (estimated glomerular filtration rate) were calculated. Patients were divided into two groups according to their injection dose: group received single dose and group received double dose. Patients in each group were subdivided into three subgroups according to their eGFR: subgroup of normal renal function, subgroup of mild renal insufficiency and subgroup of moderate renal insufficiency. Paried sample t test and group design paired sample Rank Sum test were used for statistical analysis. Results: There was no adverse reaction or occurrence of acute renal insufficiency. The mean level of serum creatinine dropped from (74.0± 17.2) μmol/L to (71.5±19.0) μmol/L (t=5.39, P 0.05) in subgroup of mild renal insufficiency under group received double dose and increased from (118.3±15.3) μmol/L to (135.7±8.5) μmol/L (t=2.02, P<0.05) in subgroup of moderate renal insufficiency under group received double dose, the mean level of serum creatinine dropped in all other subgroups. Conclusions: Single dose gadopentetate dimeglumine is safe for patients with normal renal function and mild, moderate renal insufficiency in short term, but patients with abnormal renal function should be followed up after double dose injection. (authors)

  15. Long-term follow-up of corticosteroid injection for traumatic olecranon bursitis.

    Science.gov (United States)

    Weinstein, P S; Canoso, J J; Wohlgethan, J R

    1984-01-01

    Forty-seven patients with traumatic olecranon bursitis were evaluated after a mean follow-up of 31 months (range 6 to 62 months). Twenty-two patients treated with bursal aspiration had delayed recovery and no complications of therapy. Twenty-five patients treated with intrabursal injection of 20 mg of triamcinolone hexacetonide had rapid recovery, usually within one week, but suffered complications such as infection (3 cases), skin atrophy (5 cases), and chronic local pain (7 cases). Since spontaneous resolution can be expected, a conservative approach is suggested in the treatment of traumatic olecranon bursitis. Images PMID:6696516

  16. Mesenchymal stromal cell injection promotes vocal fold scar repair without long-term engraftment

    Science.gov (United States)

    BARTLETT, R.S.; GUILLE, J.T.; CHEN, X.; CHRISTENSEN, M.B.; WANG, S.F.; THIBEAULT, S.L.

    2016-01-01

    Background Regenerative medicine holds promise for restoring voice in patients with vocal fold scarring. As experimental treatments approach clinical translation, several considerations remain. Our objective was to evaluate efficacy and biocompatibility of four bone marrow mesenchymal stromal cell (BM-MSC) and tunable hyaluronic acid based hydrogel (HyStem-VF) treatments for vocal fold scar using clinically acceptable materials, a preclinical sample size and a dosing comparison. Methods Vocal folds of 84 rabbits were injured and injected with four treatment variations (BM-MSC, HyStem-VF, and BM-MSC in HyStem-VF at two concentrations) 6 weeks later. Efficacy was assessed with rheometry, real-time polymerase chain reaction (PCR) and histology at 2, 4 and 10 weeks following treatment. Lung, liver, kidney, spleen and vocal folds were screened for biocompatibility by a pathologist. Results and discussion Persistent inflammation was identified in all hydrogel-injected groups. The BM-MSC alone treatment appeared to be the most efficacious and safe, providing an early resolution of viscoelasticity, gene expression consistent with desirable extracellular matrix remodeling (less fibronectin, collagen 1α2, collagen 3, procollagen, transforming growth factor [TGF]β1, alpha smooth muscle actin, interleukin-1β, interleukin-17β and tumor necrosis factor [TNF] than injured controls) and minimal inflammation. Human beta actin expression in BM-MSC–treated vocal folds was minimal after 2 weeks, suggesting that paracrine signaling from the BM-MSCs may have facilitated tissue repair. PMID:27637759

  17. The SSRL linacs for injection to the storage ring and rf gun testing

    International Nuclear Information System (INIS)

    Park, Sanghyun; Weaver, James N.

    1996-01-01

    The Stanford Synchrotron Radiation Laboratory (SSRL) operates two linac systems. One has three SLAC type linac sections powered by two klystrons for injection of electrons at 120 MeV into the booster ring, boosting the energy to 2.3 GeV to fill the SPEAR. After the ramping, the SPEAR stores up to 100 mA of the beam at 3.0 GeV. The preinjector consists of a thermionic RF gun, an alpha magnet, and a chopper along with focusing magnets. The other has one 10 foot section powered by the injector klystron for the testing of RF gun with photocathode, which is driven by a separate klystron. This paper describes present systems with their operational parameters, followed by plans for the upgrades and RF gun development efforts at the SSRL. (author)

  18. English-Japanese terms in nondestructive testing specifications

    International Nuclear Information System (INIS)

    1991-01-01

    For technical development, it is the prerequisite to clarify the terms to be used in various fields and their definition, therefore, in various foreign countries, there are some standards on terms in respective fields, and also as international standards, ISO/TC 135 (Non-destructive testing) organized the SC on terms from the beginning of foundation. In JIS, there is the column for corresponding English (for reference), but there is the problem of English and American English. The English used in ISO, BS or EN and ASTM standards in relation to nondestructive testing were collected in every technical field and put in order, and the corresponding English terms were selected. Moreover at this opportunity, the terms having the definition in these international, national and semi-national standards were classified into eight fields, that is, common (approval, quality assurance, defects and others), radiography, ultrasonic flaw detection, acoustic emission, eddy current flaw detection, magnetic flaw detection, liquid penetrant testing and leak test, and the Japanese translation was stipulated. The draft of this standard was approved by the standardization committee on January 17, 1991. (K.I.)

  19. Assessment of leak detection capability of Candu 6 annulus gas system using moisture injection tests

    International Nuclear Information System (INIS)

    Nho, Ki Man; Kim, Wang Bae

    1998-01-01

    The Candu 6 reactor assembly consists of an array of 380 pressure tubes, which are installed horizontally in a large cylindrical vessel, the Calandria, containing the low pressure heavy water moderator. The pressure tube is located inside calandria tube and the annulus between these tubes, which forms a closed loop with CO 2 gas recirculating, is called the Annulus Gas System (AGS). It is designed to give an alarm to the operator even for a small pressure tube leak by a very sensitive dew point meter so that he can take a preventive action for the pressure tbe rupture incident. To judge whether the operator action time is enough or not in the design of Wolsung 2, 3, and 4, the Leak Before Break (LBB) assessment is required for the analysis of the pressure tube failure accident. In order to provide the required data for the LBB assessment of Wolsung Units 2, 3, 4, a series of leak detection capability tests was performed by injecting controlled rates of heavy water vapour. The data of increased dew point and rates of rise were measured to determine the alarm set point for dew point rate of rise of Wolsung Unit 2. It was found that the response of the dew point depends on the moisture injection rate, CO 2 gas flow rate and the leak location. The test showed that Candu 6 AGS can detect the very small leaks less than few g/hr and dew point rate of rise alarm can be the most reliable alarm signal to warn the operator. Considering the present results, the first response time of dew point to the AGS CO 2 flow rate is approximated. (author)

  20. Effects of zinc injection from hot functional test at Tomari Unit 3

    International Nuclear Information System (INIS)

    Hayakawa, Hitoshi; Mino, Yoshitaka; Nakahama, Satoshi; Aizawa, Yamato; Shimizu, Yuichi; Umehara, Ryuji; Kogawa, Noritaka

    2012-09-01

    At Tomari Nuclear Power Station unit 3 (hereafter Tomari unit 3, PWR, commercial operation from December 2009), the zinc injection for dose-rate reduction was started as early as at the Hot Functional Test (hereafter HFT) stage, for the first time in the world. The results of the Steam Generator (hereafter SG) insert plate analysis and the ambient dose-rate measurement till the end of the test operation reported heretofore, show the formation of the robust oxide film on the primary material surfaces and the associated corrosion suppression effect, and a considerable dose-rate reduction of about 40 to 60% lower than a reference plant. (*: Asian Water Chemistry Symposium in Nagoya on 2009 and NPC2010 in Canada). The material of SG tube is Alloy 690TT in Tomari unit 3. Generally, the dose-rates of the plants with Alloy 690TT SG are the highest at the 1. or 2. refueling outage (hereafter RFO), due to the effects of the Ni dissolution from the initial corrosion of Alloy 690TT. Therefore, the dose-rate of Tomari unit 3 at the 1. RFO is compared with those of the other Japanese PWR plants at their 1. RFO. As the result, the dose-rates inside the main components such as SG, Main Coolant Pipe (hereafter MCP) and Reactor Vessel (hereafter RV) are about 50% lower at the 1. RFO of Tomari unit 3 than those of a reference plant (a 3-Loop PWR plant in Japan). Therefore, an additional dose-rate reduction effects is expected by the Ni release rate reduction from Alloy 690TT and the effect of zinc injection. In this report, the actual dose-rates at the primary main components, the trends of the water chemistry and dose rates reduction effect with the zinc injection at the 1. RFO (offline in January 2011) of Tomari unit 3 are introduced. Also, a part of the experiences at the 2. RFO (offline in May 2012) is introduced. (authors)

  1. Enhancement effects of test injection with a small amount of MR contrast medium in the oral and maxillofacial region

    International Nuclear Information System (INIS)

    Yanagi, Yoshinobu; Asaumi, Jun-ichi; Konouchi, Hironobu; Hisatomi, Miki; Matsuzaki, Hidenobu; Murakami, Jun; Maki, Yuu; Unetsubo, Teruhisa; Kishi, Kanji

    2006-01-01

    Purpose: To examine whether the signal intensity of dynamic contrast-enhanced MRI (DCE-MRI) is altered by test injection of 1 ml of contrast medium, and if so, whether this change affects the DCE-MRI analysis. Materials and methods: Six healthy volunteers were examined by DCE-MRI using a Magnevist syringe and/or an Omniscan syringe for the injection of contrast medium. Each scan was performed 10 times using steady-state free precession (3D-FISP), a sequence for DCE-MRI, before and after intravenous injection of 1 ml of the contrast medium. The internal pterygoid muscle, masseter muscle, tongue, parotid gland, submandibular gland, bone marrow of the mandible, subcutaneous adipose tissue, and common carotid artery were determined to be regions of interest (ROI), and the ROI internal average signal intensity was measured. The 10 data sets obtained before or after contrast medium administration for each ROI were evaluated using the paired t-test. Results: The test injection increased the signal intensities of six of eight ROIs, with all 20 experiments in the submandibular gland showing significant differences. There was no significant difference in the two ROIs corresponding to the carotid artery and subcutaneous adipose tissue of the cheek. Conclusions: The enhanced signal intensity in the tissue might have been caused by the small amount of contrast medium in the test injection. To eliminate this discrepancy caused by the test injection, a pre-contrast scan should be performed when the average signal intensity of an ROI is measured. We therefore believe that the data obtained before a test injection may be important in the analysis of DCE-MRI

  2. Vocal Fold Augmentation with Injectable Polycaprolactone Microspheres/Pluronic F127 Hydrogel: Long-Term In Vivo Study for the Treatment of Glottal Insufficiency

    Science.gov (United States)

    Kwon, Seong Keun; Kim, Hee-Bok; Song, Jae-Jun; Cho, Chang Gun; Park, Seok-Won; Choi, Jong-Sun; Ryu, Junsun; Oh, Se Heang; Lee, Jin Ho

    2014-01-01

    There is increasing demand for reconstruction of glottal insufficiency. Several injection materials have been examined for this purpose, but all had limitations, such as poor long-term durability, migration from the injection site, inflammation, granuloma formation, and interference with vocal fold vibration due to viscoelastic mismatch. Here, we developed a novel injection material, consisting of polycaprolactone (PCL) microspheres, which exhibits better viscoelasticity than conventional materials, and Pluronic F127 carrier, which decreases the migration of the injection materials. The material was injected into rabbits with glottal insufficiency and compared with the FDA-approved injection material, calcium hydroxylapatite (CaHA). Endoscopic and histological examinations indicated that PCL/Pluronic F127 remained at the injection site with no inflammatory response or granuloma formation, whereas CaHA leaked out and migrated from the injection site. Therefore, vocal fold augmentation was almost completely retained during the 12-month follow-up period in this study. Moreover, induced phonation and high-speed recording of vocal fold vibration showed decreased vocal fold gap area in the PCL/Pluronic F127 group. Our newly developed injection material, PCL/Pluronic F127, permits efficient augmentation of paralyzed vocal fold without complications, a concept that can be applied clinically, as demonstrated by the successful long-term follow-up. PMID:24465582

  3. Measurement of distribution coefficients using a radial injection dual-tracer test

    International Nuclear Information System (INIS)

    Pickens, J.F.; Jackson, R.E.; Inch, K.J.; Merritt, W.F.

    1981-01-01

    The dispersive and adsorptive properties of a sandy aquifer were evaluated by using a radial injection dual-tracer test with 131 I as the nonreactive tracer and 85 Sr as the reactive tracer. The tracer migration was monitored by using multilevel point-sampling devices located at various radial distances and depths. Nonequilibrium physical and chemical adsorption effects for 85 Sr were treated as a spreading or dispersion mechanism in the breakthrough curve analysis. The resulting effective dispersivity values for 85 Sr were typically a factor of 2 to 5 larger than those obtained for 131 I. The distribution coefficient (K/sub d//sup Sr/) values obtained from analysis of the breakthrough curves at three depths and two radial distances ranged from 2.6 to 4.5 ml/g. These compare favorably with values obtained by separation of fluids from solids in sediment cores, by batch experiments on core sediments and by analysis of a 25-year-old radioactive waste plume in another part of the same aquifer. Correlations of adsorbed 85 Sr radioactivity with grain size fractions demonstrated preferential adsorption to the coarsest fraction and to the finest fraction. The relative amounts of electrostatically and specifically adsorbed 85 Sr on the aquifer sediments were determined with desorption experiments on core sediments using selective chemical extractants. The withdrawal phase breakthrough curves for the well, obtained immediately following the injection phase, showed essentially full tracer recoveries for both 131 I and 85 Sr. Relatively slow desorption of 85 Sr provided further indication of the nonequilibrium nature of the adsorption-desorption phenomena

  4. Media-fill simulation tests in manual and robotic aseptic preparation of injection solutions in syringes.

    Science.gov (United States)

    Krämer, Irene; Federici, Matteo; Kaiser, Vanessa; Thiesen, Judith

    2016-04-01

    The purpose of this study was to evaluate the contamination rate of media-fill products either prepared automated with a robotic system (APOTECAchemo™) or prepared manually at cytotoxic workbenches in the same cleanroom environment and by experienced operators. Media fills were completed by microbiological environmental control in the critical zones and used to validate the cleaning and disinfection procedures of the robotic system. The aseptic preparation of patient individual ready-to-use injection solutions was simulated by using double concentrated tryptic soy broth as growth medium, water for injection and plastic syringes as primary packaging materials. Media fills were either prepared automated (500 units) in the robot or manually (500 units) in cytotoxic workbenches in the same cleanroom over a period of 18 working days. The test solutions were incubated at room temperature (22℃) over 4 weeks. Products were visually inspected for turbidity after a 2-week and 4-week period. Following incubation, growth promotion tests were performed with Staphylococcus epidermidis. During the media-fill procedures, passive air monitoring was performed with settle plates and surface monitoring with contact plates on predefined locations as well as fingerprints. The plates got incubated for 5-7 days at room temperature, followed by 2-3 days at 30-35℃ and the colony forming units (cfu) counted after both periods. The robot was cleaned and disinfected according to the established standard operating procedure on two working days prior to the media-fill session, while on six other working days only six critical components were sanitized at the end of the media-fill sessions. Every day UV irradiation was operated for 4 h after finishing work. None of the 1000 media-fill products prepared in the two different settings showed turbidity after the incubation period thereby indicating no contamination with microorganisms. All products remained uniform, clear, and light

  5. Short term mutagenicity tests and their application to irradiated foods

    International Nuclear Information System (INIS)

    Phillips, B.J.; Elias, P.S.

    1980-01-01

    Although traditional long-term animal tests are likely to continue to be required, these are not only extremely costly but are coming more and more to be recognised as an imprecise and unsatisfactory method of testing the safety of irradiated foods for human consumption. It is therefore clearly advisable to include a selection of quicker and more direct testing methods in any toxicological assessment procedures. The International Project has therefore undertaken a study of the feasibility of using the newer systems for investigation of irradiated foodstuffs. Although some work in this field has already been carried out, some shortcomings in the published work can be identified which justify a more detailed and intensive research programme. As expected, little difficulty has been encountered in testing food by methods involving mammals, but considerable effort has been required to adapt in vitro systems. The use of enzymatic digestion in vitro to provide food samples for testing in mammalian cell cultures has never been attempted before and the procedures developed by the Project represent a positive contribution to methodology in this field. A series of foodstuffs is being tested by a wide spectrum of short-term tests and the first results are now being obtained. (orig./MG) [de

  6. Cold leg injection reflood test results in the SCTF Core-I under constant system pressure

    International Nuclear Information System (INIS)

    Adachi, Hiromichi; Iwamura, Takamichi; Sobajima, Makoto; Osakabe, Masahiro; Ohnuki, Akira; Abe, Yutaka; Murao, Yoshio.

    1990-08-01

    The Slab Core Test Facility (SCTF) was constructed to investigate two-dimensional thermal-hydrodynamics in the core and the interaction in fluid behavior between the core and the upper plenum during the last part of blowdown, refill and reflood phases of a postulated loss-of-coolant accident (LOCA) of a pressurized water reactor (PWR). The present report describes the analytical results on the system behavior observed in the SCTF Core-I cold leg injection tests, S1-14 (Run 520), S1-15 (521), S1-16 (522), S1-17 (523), S1-20 (530), S1-21 (531), S1-23 (536) and S1-24 (537), performed under constant system pressure condition during transient. Major discussion items are: (1) steam binding, (2) U-tube oscillations, (3) bypass of ECC water (4) core cooling behavior, (5) effect of vent valve and (6) other parameter effects. These results give us very useful information and suggestion on reflood behavior. (author)

  7. Long-term effects of 239Pu injection in adult, weanling, newborn and fetal rats

    International Nuclear Information System (INIS)

    Sikov, M.R.; Mahlum, D.D.; Hess, J.O.; Carr, D.B.

    1979-01-01

    We have completed biological evaluations comparing long-term effects in rats exposed to 239 Pu citrate as adults, weanlings, newborns, or late fetuses, and statistical analyses have been initiated. In rats exposed postnatally, statistically significant alterations in terminal body weight and in weights of several organs were found at higher doses. Survivorship decreased with increasing dose in the postnatal groups, but not in rats exposed prenatally

  8. Prediction of the Long Term Cooling Performance for the 3-Pin Fuel Test Loop

    Energy Technology Data Exchange (ETDEWEB)

    Park, S. K.; Chi, D. Y.; Sim, B. S.; Park, K. N.; Ahn, S. H.; Lee, J. M.; Lee, C. Y.; Kim, H. R

    2005-12-15

    In the long term cooling phase that the emergency cooling water injection ends, the performance of the residual heat removal for the 3-pin fuel test loop has been predicted by a simplified heat transfer model. In the long term cooling phase the residual heat is 1323W for PWR fuel test mode and 1449W for CANDU fuel test mode. The each residual heat is assumed as 2% of the fission power of the test fuel used in the anticipated operational occurrence and design basis accident analyses. The each fission power used for the analyses is 105% of the rated fission power in the normal operation. In the long term cooling phase the residual heat is removed to the HANARO pool through the double pressure vessels of the in-pile test section. Saturate pooling boiling is assumed on the test fuel and condensation heat transfer is expected on the inner wall of the fuel carrier and the flow divider. Natural convection heat transfer on a heated vertical wall is also assumed on the outer wall of the outer pressure vessel. The conduction heat transfer is only considered in the gap between the double pressure vessels charged with neon gas and in the downcomer filled with coolant. The heat transfer rate between the coolant temperature of 152 .deg. C in the in-pile test section and the water temperature of 45 .deg. C in the HANARO pool is predicted as about 1666W. The 152 .deg. C is the saturate temperature of the coolant pressure predicted from the MARS code. The cooling capacity of 1666W is greater than the residual heats of 1323W and 1449W. Consequently the long term cooling performance of the 3-pin fuel test loop is sufficient for the anticipated operational occurrences and design basis accidents.

  9. Injection Laryngoplasty Materials

    OpenAIRE

    Haldun Oðuz

    2013-01-01

    Injection laryngoplasty is one of the treatment options for voice problems. In the recent years, more safe and more biocompatible injection materials are available on the market. Long and short term injection materials are discussed in this review.

  10. Fault injection as a test method for an FPGA in charge of data readout for a large tracking detector

    CERN Document Server

    Roed, K; Richter, M; Fehlker, D; Helstrup, H; Alme, J; Ullaland, K

    2011-01-01

    This paper describes how fault injection has been implemented as a test method for an FPGA in an existing hardware configuration setup. As this FPGA is in charge of data readout for a large tracking detector, the reliability of this FPGA is of high importance. Due to the complexity of the readout electronics, irradiation testing is technically difficult at this stage of the system commissioning. The work presented in this paper is therefore motivated by introducing fault injection as an alternative method to characterize failures caused by SEUs. It is a method to study the effect that a configuration upset may have on the operation of the FPGA. The target platform consists of two independent modules for data acquisition and detector control functionality. Fault injection to test the response of the data acquisition module is made possible by implementing the solution as part of the detector control functionality. Correct implementation is validated by a simple shift register design. Our results demonstrate th...

  11. Transition from depressurization to long term cooling in AP600 scaled integral test facilities

    International Nuclear Information System (INIS)

    Bessette, D.E.; Marzo, M. di

    1999-01-01

    A novel light water reactor design called the AP600 has been proposed by the Westinghouse Electric Corporation. In the evaluation of this plant's behavior during a small break loss of coolant accident (LOCA), the crucial transition to low pressure, long-term cooling is marked by the injection of the gravitationally driven flow from the in-containment refueling water storage tank (IRWST). The onset of this injection is characterized by intermittency in the IRWST flow. This happens at a time when the reactor vessel reaches its minimum inventory. Therefore, it is important to understand and scale the behavior of the integral experimental test facilities during this portion of the transient. The explanation is that the periodic liquid drains and refills of the pressurizer are the reason for the intermittent behavior. The momentum balance for the surge line yields the nondimensional parameter controlling this process. Data from one of the three experimental facilities represent the phenomena well at the prototypical scale. The impact of the intermittent IRWST injection on the safe plant operation is assessed and its implications are successfully resolved. The oscillation is found to result from, in effect, excess water in the primary system and it is not of safety significance. (orig.)

  12. Summary of air permeability data from single-hole injection tests in unsaturated fractured tuffs at the Apache Leap Research Site: Results of steady-state test interpretation

    International Nuclear Information System (INIS)

    Guzman, A.G.; Geddis, A.M.; Henrich, M.J.; Lohrstorfer, C.F.; Neuman, S.P.

    1996-03-01

    This document summarizes air permeability estimates obtained from single hole pneumatic injection tests in unsaturated fractured tuffs at the Covered Borehole Site (CBS) within the larger apache Leap Research Site (ALRS). Only permeability estimates obtained from a steady state interpretation of relatively stable pressure and flow rate data are included. Tests were conducted in five boreholes inclined at 45 degree to the horizontal, and one vertical borehole. Over 180 borehole segments were tested by setting the packers 1 m apart. Additional tests were conducted in segments of lengths 0.5, 2.0, and 3.0 m in one borehole, and 2.0 m in another borehole, bringing the total number of tests to over 270. Tests were conducted by maintaining a constant injection rate until air pressure became relatively stable and remained so for some time. The injection rate was then incremented by a constant value and the procedure repeated. The air injection rate, pressure, temperature, and relative humidity were recorded. For each relatively stable period of injection rate and pressure, air permeability was estimated by treating the rock around each test interval as a uniform, isotropic porous medium within which air flows as a single phase under steady state, in a pressure field exhibiting prolate spheroidal symmetry. For each permeability estimate the authors list the corresponding injection rate, pressure, temperature and relative humidity. They also present selected graphs which show how the latter quantities vary with time; logarithmic plots of pressure versus time which demonstrate the importance of borehole storage effects during the early transient portion of each incremental test period; and semilogarithmic plots of pressure versus recovery time at the end of each test sequence

  13. Comparison of in-plant performance test data with analytic prediction of reactor safety system injection transient (U)

    International Nuclear Information System (INIS)

    Roy, B.N.; Neill, C.H. Jr.

    1993-01-01

    This paper compares the performance test data from injection transients for both of the subsystems of the Supplementary Safety System of the Savannah River Site production reactor with analytical predictions from an in-house thermal hydraulic computer code. The code was initially developed for design validation of the new Supplementary Safety System subsystem, but is shown to be equally capable of predicting the performance of the Supplementary Safety System existing subsystem even though the two subsystem transient injections have marked differences. The code itself was discussed and its validation using prototypic tests with simulated fluids was reported in an earlier paper (Roy and Nomm 1991)

  14. Commissioning of the LHCb Silicon Tracker using data from the LHC injection tests

    CERN Document Server

    Knecht, M; Blanc, F; Bettler, M-O; Conti, G; Fave, V; Frei, R; Gauvin, N; Haefeli, G; Keune, A; Luisier, J; Muresan, R; Nakada, T; Needham, M; Nicolas, L; Perrin, A; Potterat, C; Schneider, O; Tran, M; Bauer, C; Britsch, M; Hofmann, W; Maciuc, F; Schmelling, M; Voss, H; Anderson, J; Buechler, A; Chiapolini, N; Hangartner, V; Salzmann, C; Steiner, S; Steinkamp, O; Van Tilburg, J; Tobin, M; Vollhardt, A; Adeva, B; Fungueiri no Pazos, J; Gallas, A; Pazos-Alvarez, A; Pérez-Trigo, E; Pló-Casasus, M; Rodriguez Perez, P; Saborido, J; Vázquez, P; Iakovenko, V; Okhrimenko, O; Pugatch, V

    2011-01-01

    LHCb is a single-arm forward spectrometer dedicated to the study of the CP-violation and rare decays in the b-quark sector. An efficient and high precision tracking system is a key requirement of the experiment. The LHCb Silicon Tracker Project consists of two sub-detectors that make use of silicon micro-strip technology: the Tracker Turicensis located upstream of the spectrometer magnet and the Inner Tracker which covers the innermost part of the tracking stations after the magnet. In total an area of 12 m^2 is covered by silicon. In September 2008 and June 2009, injection tests from the SPS to the LHC were performed. Bunches of order 5x10^9 protons were dumped onto a beam stopper (TED) located upstream of LHCb. This produced a spray of ~10 GeV muons in the LHCb detector. Though the occupancy in this environment is relatively large, these TED runs have allowed a first space and time alignment of the tracking system. Results of these studies together and the overall detector performance obtained in the TED ru...

  15. Test results of pongamia pinnata methyl esters with direct injection diesel engine

    International Nuclear Information System (INIS)

    Bannikov, MG.; Chattha, J.A.; Khan, A.F.

    2011-01-01

    Pongamia Pinnata oil is considered as a potential source of biodiesel production in Pakistan. When selecting source for commercial production of biodiesel several criteria are used. One of them is that biodiesel or biodiesel/diesel fuel blends must provide satisfactory performance and emissions of the diesel engine without or with a little engine modification. In this research performance and emissions characteristics of a direct injection diesel engine running on Pongamia Pinnata methyl esters were discussed. Discussion was supported by an analysis of combustion characteristics derived from in-cylinder pressure data. Engine running on a neat biodiesel showed higher brake specific fuel consumption and lower brake fuel conversion efficiency at all loads, whereas emissions were improved except of carbon monoxide emission at high loads. Decrease in brake efficiency and reduction of nitrogen oxides emissions were attributed solely to the change in the rate of heat release. Deposits on fuel infector nozzle were observed when engine was running on the neat biodiesel. Based on test results conclusion was made that Pongamia biodiesel/diesel fuel blends can effectively be used as a diesel oil substitute. (author)

  16. Sensation of Cold during the Ice Water Test Corresponds to the Perception of Pain during Botulinum Toxin Bladder Wall Injections.

    Science.gov (United States)

    Reitz, André; Hüsch, Tanja; Doggweiler, Regula; Buse, Stephan; Haferkamp, Axel

    2018-01-01

    To investigate the association of bladder cold sensation (BCS) during the ice water test (IWT) and pain perception when botulinum toxin injections (BTI) are administered into the bladder wall. In 86 patients with idiopathic overactive bladder, the BCS during the IWT was investigated. Patients were divided into 2 groups: with and without BCS. During subsequent administration of BTI, the number of perceived and painful injections as well as the pain levels on a 0-100 pain scale were compared in both groups using Student t test. Thirty-five patients reported a BCS, while 51 did not. After 10 BTI, the mean number of perceived injections was 7.9 in patients with and 2.4 in patients without BCS (p sensation (p perceptions of cold and pain in the urinary bladder may use similar receptors and neuronal pathways. © 2018 S. Karger AG, Basel.

  17. DOE/NETL's phase II mercury control technology field testing program: preliminary economic analysis of activated carbon injection.

    Science.gov (United States)

    Jones, Andrew P; Hoffmann, Jeffrey W; Smith, Dennis N; Feeley, Thomas J; Murphy, James T

    2007-02-15

    Based on results of field testing conducted by the U.S. Department of Energy's National Energy Technology Laboratory (DOE/NETL), this article provides preliminary costs for mercury control via conventional activated carbon injection (ACI), brominated ACI, and conventional ACI coupled with the application of a sorbent enhancement additive (SEA) to coal prior to combustion. The economic analyses are reported on a plant-specific basis in terms of the cost required to achieve low (50%), mid (70%), and high (90%) levels of mercury removal "above and beyond" the baseline mercury removal achieved by existing emission control equipment. In other words, the levels of mercury control are directly attributable to ACI. Mercury control costs via ACI have been amortized on a current dollar basis. Using a 20-year book life, levelized costs for the incremental increase in cost of electricity (COE), expressed in mills per kilowatt-hour (mills/kWh), and the incremental cost of mercury control, expressed in dollars per pound of mercury removed ($/lb Hg removed), have been calculated for each level of ACI mercury control. For this analysis, the increase in COE varied from 0.14 mills/kWh to 3.92 mills/kWh. Meanwhile, the incremental cost of mercury control ranged from $3810/lb Hg removed to $166000/lb Hg removed.

  18. Use of remifentanil to reduce propofol injection pain and the required propofol dose in upper digestive tract endoscopy diagnostic tests.

    Science.gov (United States)

    Uliana, Gustavo Nadal; Tambara, Elizabeth Milla; Baretta, Giorgio Alfredo Pedroso

    2015-01-01

    The introduction of propofol (2,6-diisopropylphenol) as a sedative agent has transformed the area of sedation for endoscopic procedures. However, a major drawback of sedation with the use of propofol is its high incidence of injection pain. The most widely used technique in reducing propofol injection pain is through the association of other drugs. The aim of this study was to evaluate the effect of remifentanil-propofol combination on the incidence of propofol injection pain and its influence on the total dose of propofol required for sedation in upper digestive tract endoscopy (UDE) diagnostic tests. One hundred and five patients undergoing upper digestive tract endoscopy were evaluated and randomly divided into 3 groups of 35 patients each. The Control Group received propofol alone; Study-group 1 received remifentanil at a fixed dose of 0.2mg/kg combined with propofol; Study-group 2 received remifentanil at a fixed dose of 0.3mg/kg combined with propofol. The incidence of propofol injection pain and the total dose of propofol required for the test were evaluated. The sample was very similar regarding age, weight, height, sex, and physical status. Statistical analysis was performed according to the nature of the evaluated data. Student's t-test was used to compare the mean of age, weight, height (cm), and dose (mg/kg) variables between groups. The χ(2) test was used to compare sex, physical status, and propofol injection pain between groups. The significance level was αpain and total dose of propofol (mg/kg) used. However, there were no statistical differences between the two study groups for these parameters. We conclude that the use of remifentanil at doses of 0.2mg/kg and 0.3mg/kg was effective for reducing both the propofol injection pain and the total dose of propofol used. Copyright © 2015 Sociedade Brasileira de Anestesiologia. Published by Elsevier Editora Ltda. All rights reserved.

  19. Long-term Results of Intravitreal Anti-VEGF Injections in Wet AMD: A Meta-Analysis.

    Science.gov (United States)

    Gerding, H

    2016-04-01

    Although intravitreal anti-VEGF medications are widely used in age-related macular degeneration, no systematic data analysis is available on the long-term prognosis of this relatively new therapeutic approach. A meta-analysis was performed on available Medline literature. 13 relevant clinical studies (14 case series) could be identified, covering 10 247 treated eyes. The majority of available reports originate from single centre retrospective real-life environments. The mean improvement in average visual gain was 0.9 ± 0.5 (mean ± 1 standard deviation, median; 0.8 lines) at year 1, 1.2 ± 1.1 (median: 1.1) letters at year 2, 0.7 ± 1.0 (median: 0.7) letters at year 3, and 0.2 ± 0.8 (median: 0.5), 0.4 ± 0.4 (median: 0.5) at years 4 and 5. The drop-out rates in these studies was relatively high. At the end of year 3, the average percentage of observed eyes was 44.3 ± 18.4 % (mean ± 1 standard deviation), at the end of year 4 23.5 ± 23.9 % and after years 6 and 7 below 10 % (8.2 and 7.9 %). The mean treatment frequency of injections in all available studies was highest in year 1 (6.4 ± 1.2, 6.1 - mean ± SD; median), followed by relatively consistent mean values of 4.1 and 5.1 (year (Y)2: 4.4, Y3: 4.3, Y4: 4.7, Y5: 4.1, Y6: 5.1, Y7: 4.7) injections per year. The results of this meta-analysis clearly indicate that intravitreal anti-VEGF injection therapy is capable of maintaining visual acuity on a long-term basis of at least 4-5 years. Georg Thieme Verlag KG Stuttgart · New York.

  20. Long-term dose-response studies of inhaled or injected radionuclides

    International Nuclear Information System (INIS)

    Boecker, B.B.; Muggenburg, B.A.; Miller, S.C.; Bradley, P.L.

    1994-01-01

    This report describes the scientific progress in, and current status of, life-span studies of the long-term health risks in Beagle dogs of chronic irradiation from internally deposited radionuclides or from an external source. The reporting period for this document is the 2-year period from October 1, 1991 through September 30, 1993. Studies that were initiated at three different laboratories (Inhalation Toxicology Research Institute, ITRI, University of Utah, and Argonne National Laboratory, ANL) are presented here because they are being completed at ITRI. All living dogs in the Utah-initiated studies were transferred to the ITRI facility for the remainder of their life-span observations and measurements in September 1987. This report is the fourth in a series of reports dealing with the current status and progress of both the Utah and ITRI studies. Other life-span studies involving dogs exposed to gamma radiation from an external source were initiated and conducted for many years at ANL. In 1991, the decision was made to discontinue the chronic irradiation of the remaining living dogs and to transfer all remaining dogs to ITRI for care, clinical observations, and pathological observations at death or euthanasia. This report provides the current status of these dogs. Status reports on the Utah and ITRI studies comprise most of this report. The ITRI-related section presents brief statements of project objectives, the general procedures used in these studies, and some study-specific features for each of the 19 studies being conducted with either beta- or alpha-emitting radionuclides. Dose- and effect-modifying factors being addressed in these studies include total dose, dose rate, LET, solubility, nonuniformity of dose, species, age, sex, health status, and mode of exposure. Recent additions to experimental protocols for studies in which dogs are still alive involve the collection and analysis of tumor tissues using currently available molecular biology techniques

  1. A longitudinal study of hepatitis C virus testing and infection status notification on behaviour change in people who inject drugs

    NARCIS (Netherlands)

    Spelman, T.; Morris, M. D.; Zang, G.; Rice, T.; Page, K.; Maher, L.; Lloyd, A.; Grebely, J.; Dore, G. J.; Kim, A. Y.; Shoukry, N. H.; Hellard, M.; Bruneau, J.; Cox, Andrea L.; Lauer, Georg; McGovern, Barbara H.; Prins, Maria; Hahn, Judy; Shiboski, Stephen; Mirzazadeh, Ali; Alavi, Maryam; Bouchard, Rachel; Evans, Jennifer; Grady, Bart; Aneja, Jasneet; Sacks-Davis, Rachel; Teutsch, Suzy; White, Bethany; Wells, Brittany; Applegate, Tanya; Matthews, Gail; Yeung, Barbara; Schinkel, Janke; Prince, Leslie Erin; Roy, Elise; Bates, Anna; Enriquez, Jarliene; Chow, Sammy; McCredie, Luke; Aitken, Campbell; Doyle, Joseph

    2015-01-01

    Background Hepatitis C virus (HCV) testing and counselling have the potential to impact individual behaviour and transmission dynamics at the population level. Evidence of the impact of an HCV-positive status notification on injection risk reduction is limited. The objective of our study was to (1)

  2. Experimental Analysis for Factors Affecting the Repeatability of Plastics Injection Molding Tests on the Self-developed Apparatus

    Directory of Open Access Journals (Sweden)

    Yugang Huang

    2013-06-01

    Full Text Available Normal 0 false false false IN X-NONE X-NONE MicrosoftInternetExplorer4 To improve the repeatability of the injection molding test result, the affecting factors were investigated by means of experiments. Besides the traditional processing parameter, the factors of test conditions were also considered. In order to focus on the molding process rather than the molded part, the curve measurement of the melt pressure at the entrance to the nozzle was used as the output characteristic. Experiments for polypropylene (PP showed that the injected volume was the key processing parameter. Within the test conditions, the injection number is the most important factor. According to the analysis the operating procedure was improved effectively. Normal 0 false false false IN X-NONE X-NONE MicrosoftInternetExplorer4 Doi: 10.12777/ijse.5.1.6-11 [How to cite this article: Huang, Y., Li, D., Liu, Y. (2013. Experimental Analysis for Factors Affecting the Repeatability of Plastics Injection Molding Tests on the Self-developed Apparatus. International Journal of Science and Engineering, 5(1,6-11. Doi: 10.12777/ijse.5.1.6-11]

  3. Phobia of self-injecting and self-testing in insulin-treated diabetes patients: opportunities for screening

    NARCIS (Netherlands)

    Mollema, E. D.; Snoek, F. J.; Heine, R. J.; van der Ploeg, H. M.

    2001-01-01

    To define clinically relevant cut-off points for severe fear of self-injecting (FSI) and self-testing (FST) (phobia) in insulin-treated patients with diabetes, and to estimate the magnitude of these phobias in our research population. FSI and FST were assessed in a cross-sectional survey using the

  4. Long-term efficacy and safety of self-intracavernous injection of prostaglandin E1 for treatment of erectile dysfunction in China.

    Science.gov (United States)

    He, L; Wen, J; Jiang, X; Chen, H; Tang, Y

    2011-06-01

    The study evaluated the long-term efficacy and safety profiles of self-intracavernous injection of prostaglandin E1 (PGE1) for erectile dysfunction (ED). Four hundred and sixteen ED patients were treated with self-intracavernous injection of PGE1 from January 1998 to December 2007 in our outpatient service. Follow-up was made to investigate the efficacy and side effects of this treatment. It was found that 261 patients (62.7%) felt satisfied and kept using this treatment due to its advantages of satisfactory efficacy and reasonable expense. Twenty-seven of them (6.5%) got rid of PGE1 treatment after five times injections and did not need any other drugs to maintain satisfactory sexual lives. Two hundred and fourteen (51.4%) patients kept using this treatment for over 1 year, 26 (6.2%) over 5 years, 12 (2.9%) over 8 years and 7 (1.7%) over 10 years. The major complications of self-intracavernous injection of PGE1 include fibrosis of corpus cavernosum (three cases), ecchymosis associated with vascular injury due to injection (23 cases) and pain associated with injection (295 cases). There were no patients displaying priapism. It is concluded that self-intracavernous injection of PGE1 is a safe and effective treatment for ED with various aetiologies and a broad range of severity, and no serious complications were observed after long-term application. © 2011 Blackwell Verlag GmbH.

  5. On-ground testing of the role of adhesion in the LISA-Pathfinder test mass injection phase

    Science.gov (United States)

    Bortoluzzi, D.; Zanoni, C.; Conklin, J. W.

    2017-05-01

    Many space missions share the need to fly a free-falling body inside the spacecraft, as a reference for navigation and/or as a probe for the local gravitational field. When a mechanism is required to cage such an object during the launch phase, the need arises to release it to free-fall once the operational phase must be initiated in orbit. The criticality of this phase increases when the mechanical interfaces between the body and the mechanism are affected by adhesion and the actuation authority of the control system on the free-falling body is limited. Both conditions are realized in the LISA Pathfinder mission, which aims at injecting a gold-coated 2 kg cubic test mass into a nearly perfect geodesic trajectory to demonstrate the readiness of the developed technology for in-space gravity wave detection. The criticality of adhesion is widely recognized in space technology, because it can affect and jeopardize the functionality of mechanisms, when arising between moving parts. In the LISA Pathfinder case, metallic adhesion potentially plays a relevant role, mainly for two reasons. First, thanks to its properties (ductility, high surface energy) the gold coating on the proof mass easily produces cold weldings, especially in vacuum conditions. Second, the detachment of the proof mass from the releasing device occurs abruptly and a relevant influence of the separation velocity is expected on the strength of the welding. This can produce an excessive velocity of the proof mass at the retraction of the releasing device for the following capture and centring phase on behalf of the control system. A testing activity is performed to characterize the dynamic behaviour of the adhesive bonds between the proof mass and the releasing device, which can be used to predict their contribution on the residual velocity of the proof mass after in-flight release. The study of such a dynamic phenomenon sets some challenging requirements on the measurement technique, both on the

  6. Long-term follow-up sonography of benign cystic thyroid nodules after a percutaneous ethanol injection: the incidence of malignancy-mimicking nodules

    International Nuclear Information System (INIS)

    Park, Ji Sung; Kim, Dong Wook; Eun, Choong Ki; Choi, Seok Jin; Rho, Myung Ho

    2008-01-01

    To evaluate the incidence of malignancy-mimicking sclerosed thyroid nodules, from long-term follow-up ultrasonography (US) after an US-guided percutaneous ethanol injection (PEI). We examined 86 benign cystic thyroid nodules from 80 patients. The nodules were classified into two groups based on whether an aspiration (Group A, n = 26) or non-aspiration (Group B, n 60) of infused ethanol was performed. The final follow-up US over 12 months was performed in all patients. Of the 86 nodules, the cystic portion of 82 (95.3%) cases, from 76 patients, completely disappeared subsequent to the first follow-up US (Group A, n = 24, Group B, n = 58) (Chi-square test, ρ > 0.05). Moreover, 46 sclerosed thyroid nodules showed two or more of the 'five sonographic criteria' upon a follow-up US (Group A, n = 13, 50.0%, Group B, n = 32, 53.3%). A higher ratio of the cystic portion of the nodules was associated with a higher incidence of the 'five sonographic criteria' for malignancies detected via a follow-up US (ρ < 0.01; Student's t-test). For the long-term follow-up US, the 'five sonographic criteria' were observed in half the patients who received US-guided PEI. Also, by acknowledging the possibility that sonographic findings mimic a malignancy, since the sclerosed thyroid nodule, patients may avoid an unnecessary biopsy

  7. Gas injection test in a borehole of the Meuse/Haute Marne underground research laboratory: experimental overview and basic data analysis

    International Nuclear Information System (INIS)

    La Vaissiere, Remi de; Talandier, Jean; Piedevache, Mederic; Helmlinger, Benjamin; Lavanchy, Jean-Marc; Croise, Jean; Senger, Rainer

    2012-01-01

    Document available in extended abstract form only. Understanding of the fate and of the impact of gas produced by corrosion of metals, microbial degradation and the radiolysis of water within a deep geological disposal repository for radioactive waste, is of major relevance in the performance assessment including the long-term evolution of the repository. To address these issues, the French national Agency for the management of radioactive waste (Andra) has directed a field scale experiment examining the mechanisms controlling gas entry and gas migration in the Callovo-Oxfordian (COX) clay, the proposed host rock of the French deep geological repository project. This experiment, called PGZ1, studies the migration of nitrogen in the COX based on gas injection tests performed in a borehole of the Meuse/Haute Marne URL. This experiment is currently being performed under the auspices of the Euratom 7. Framework FORGE project. In this poster, we provide an overview on the field data and a basic analysis of the data. The advanced interpretation of the data was based on numerical modeling of the two-phase flow with 3 different approaches and numerical codes. The experimental layout consists of three boreholes. Two parallel boreholes (PGZ1201 and PGZ1202) were drilled from the GED drift and are equipped with a triple interval system to monitor the pressure evolutions in 3 intervals, associated with the hydraulic and gas injection tests in the selected test interval (PGZ1201, middle interval). The third borehole (PGZ1031) was drilled from the GEX drift and is equipped with an extensometer probe, to monitor potential deformation associated with the resulting stress changes. An initial hydraulic test (HYDRO1) was performed in the test interval to estimate the hydraulic conductivity of the COX prior to gas testing. The hydraulic test consisted in a sequence of injections of synthetic formation water (pressure pulse followed by a constant pressure and a final shut-in phase

  8. Prospective testing of Coulomb short-term earthquake forecasts

    Science.gov (United States)

    Jackson, D. D.; Kagan, Y. Y.; Schorlemmer, D.; Zechar, J. D.; Wang, Q.; Wong, K.

    2009-12-01

    Earthquake induced Coulomb stresses, whether static or dynamic, suddenly change the probability of future earthquakes. Models to estimate stress and the resulting seismicity changes could help to illuminate earthquake physics and guide appropriate precautionary response. But do these models have improved forecasting power compared to empirical statistical models? The best answer lies in prospective testing in which a fully specified model, with no subsequent parameter adjustments, is evaluated against future earthquakes. The Center of Study of Earthquake Predictability (CSEP) facilitates such prospective testing of earthquake forecasts, including several short term forecasts. Formulating Coulomb stress models for formal testing involves several practical problems, mostly shared with other short-term models. First, earthquake probabilities must be calculated after each “perpetrator” earthquake but before the triggered earthquakes, or “victims”. The time interval between a perpetrator and its victims may be very short, as characterized by the Omori law for aftershocks. CSEP evaluates short term models daily, and allows daily updates of the models. However, lots can happen in a day. An alternative is to test and update models on the occurrence of each earthquake over a certain magnitude. To make such updates rapidly enough and to qualify as prospective, earthquake focal mechanisms, slip distributions, stress patterns, and earthquake probabilities would have to be made by computer without human intervention. This scheme would be more appropriate for evaluating scientific ideas, but it may be less useful for practical applications than daily updates. Second, triggered earthquakes are imperfectly recorded following larger events because their seismic waves are buried in the coda of the earlier event. To solve this problem, testing methods need to allow for “censoring” of early aftershock data, and a quantitative model for detection threshold as a function of

  9. Kepler Planet Detection Metrics: Per-Target Flux-Level Transit Injection Tests of TPS for Data Release 25

    Science.gov (United States)

    Burke, Christopher J.; Catanzarite, Joseph

    2017-01-01

    Quantifying the ability of a transiting planet survey to recover transit signals has commonly been accomplished through Monte-Carlo injection of transit signals into the observed data and subsequent running of the signal search algorithm (Gilliland et al., 2000; Weldrake et al., 2005; Burke et al., 2006). In order to characterize the performance of the Kepler pipeline (Twicken et al., 2016; Jenkins et al., 2017) on a sample of over 200,000 stars, two complementary injection and recovery tests are utilized:1. Injection of a single transit signal per target into the image or pixel-level data, hereafter referred to as pixel-level transit injection (PLTI), with subsequent processing through the Photometric Analysis (PA), Presearch Data Conditioning (PDC), Transiting Planet Search (TPS), and Data Validation (DV) modules of the Kepler pipeline. The PLTI quantification of the Kepler pipeline's completeness has been described previously by Christiansen et al. (2015, 2016); the completeness of the final SOC 9.3 Kepler pipeline acting on the Data Release 25 (DR25) light curves is described by Christiansen (2017).2. Injection of multiple transit signals per target into the normalized flux time series data with a subsequent transit search using a stream-lined version of the Transiting Planet Search (TPS) module. This test, hereafter referred to as flux-level transit injection (FLTI), is the subject of this document. By running a heavily modified version of TPS, FLTI is able to perform many injections on selected targets and determine in some detail which injected signals are recoverable. Significant numerical efficiency gains are enabled by precomputing the data conditioning steps at the onset of TPS and limiting the search parameter space (i.e., orbital period, transit duration, and ephemeris zero-point) to a small region around each injected transit signal.The PLTI test has the advantage that it follows transit signals through all processing steps of the Kepler pipeline, and

  10. HM modelling of in-situ gas injection tests in bentonite and argillite: the PGZ experiment

    International Nuclear Information System (INIS)

    Gerard, P.; Charlier, R.; Radu, J.P.; La Vaissiere, R. de; Talandier, J.; Collin, F.

    2010-01-01

    Document available in extended abstract form only. During long-term repository of high and intermediate level nuclear waste in deep argillaceous geological formation, steel containers will corroded and organic material will be irradiated. The two processes lead mostly to hydrogen production. This study deals with the numerical modelling of the gas migration in both the host formation and a bentonite plug, with an emphasis on coupling between the gas transfer and the mechanical strains and stresses. More particularly the study aims to support the design of the PGZ in situ experiment that will be performed by Andra in its underground laboratory at Bure. The objective of the experiment is the analysis of the dynamics of the bentonite plug re-saturation, studying the competition between the liquid water coming from the argillite and a gas injection. The modelled experiment consists of a borehole drilled in rock clay, inside which a plug of MX-80 bentonite is set. The bentonite is naturally re-saturated by water coming from the host formation. At the same time a gas pressure, higher than the initial water pressure in the host rock, is imposed at both ends of the plug. The developed model takes into account the coupling between the mechanical behaviour and the water and gas transfers in undisturbed geo-materials. It manages explicitly liquid and vapour water, gaseous and dissolved hydrogen. Elastoplastic and non-linear elastic model are used to model the behaviour of, respectively, the argillaceous rock and the bentonite. The numerical results show the small desaturation obtained in bentonite and argillite. The influence of the coupling of the mechanic on the water and gas transfers is thus limited (due to the Bishop's effective stress). The swelling of the bentonite plug is not hindered by the gas migration and the confining effect of the engineered barrier is maintained. An analysis is made of the influence of the main transfer rock properties on the gas pressure

  11. Optimization of parameters for the inline-injection system at Brookhaven Accelerator Test Facility

    International Nuclear Information System (INIS)

    Parsa, Z.; Ko, S.K.

    1995-01-01

    We present some of our parameter optimization results utilizing code PARMLEA, for the ATF Inline-Injection System. The new solenoid-Gun-Solenoid -- Drift-Linac Scheme would improve the beam quality needed for FEL and other experiments at ATF as compared to the beam quality of the original design injection system. To optimize the gain in the beam quality we have considered various parameters including the accelerating field gradient on the photoathode, the Solenoid field strengths, separation between the gun and entrance to the linac as well as the (type size) initial charge distributions. The effect of the changes in the parameters on the beam emittance is also given

  12. Heavy oil reservoir evaluation : performing an injection test using DST tools in the marine region of Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Loaiza, J.; Ruiz, P. [Halliburton, Mexico City (Mexico); Barrera, D.; Gutierrez, F. [Pemex, Mexico City (Mexico)

    2010-07-01

    This paper described an injection test conducted to evaluate heavy oil reserves in an offshore area of Mexico. The drill-stem testing (DST) evaluation used a fluid injection technique in order to eliminate the need for artificial lift and coiled tubing. A pressure transient analysis method was used to determine the static pressure of the reservoir, effective hydrocarbon permeability, and formation damage. Boundary effects were also characterized. The total volume of the fluid injection was determined by analyzing various reservoir parameters. The timing of the shut-in procedure was determined by characterizing rock characteristics and fluids within the reservoir. The mobility and diffusivity relationships between the zones with the injection fluids and reservoir fluids were used to defined sweep fluids. A productivity analysis was used to predict various production scenarios. DST tools were then used to conduct a pressure-production assessment. Case histories were used to demonstrate the method. The studies showed that the method provides a cost-effective means of providing high quality data for productivity analyses. 4 refs., 2 tabs., 15 figs.

  13. Long Term Corrosion/Degradation Test Six Year Results

    Energy Technology Data Exchange (ETDEWEB)

    M. K. Adler Flitton; C. W. Bishop; M. E. Delwiche; T. S. Yoder

    2004-09-01

    The Subsurface Disposal Area (SDA) of the Radioactive Waste Management Complex (RWMC) located at the Idaho National Engineering and Environmental Laboratory (INEEL) contains neutron-activated metals from non-fuel, nuclear reactor core components. The Long-Term Corrosion/Degradation (LTCD) Test is designed to obtain site-specific corrosion rates to support efforts to more accurately estimate the transfer of activated elements to the environment. The test is using two proven, industry-standard methods—direct corrosion testing using metal coupons, and monitored corrosion testing using electrical/resistance probes—to determine corrosion rates for various metal alloys generally representing the metals of interest buried at the SDA, including Type 304L stainless steel, Type 316L stainless steel, Inconel 718, Beryllium S200F, Aluminum 6061, Zircaloy-4, low-carbon steel, and Ferralium 255. In the direct testing, metal coupons are retrieved for corrosion evaluation after having been buried in SDA backfill soil and exposed to natural SDA environmental conditions for times ranging from one year to as many as 32 years, depending on research needs and funding availability. In the monitored testing, electrical/resistance probes buried in SDA backfill soil will provide corrosion data for the duration of the test or until the probes fail. This report provides an update describing the current status of the test and documents results to date. Data from the one-year and three-year results are also included, for comparison and evaluation of trends. In the six-year results, most metals being tested showed extremely low measurable rates of general corrosion. For Type 304L stainless steel, Type 316L stainless steel, Inconel 718, and Ferralium 255, corrosion rates fell in the range of “no reportable” to 0.0002 mils per year (MPY). Corrosion rates for Zircaloy-4 ranged from no measurable corrosion to 0.0001 MPY. These rates are two orders of magnitude lower than those specified in

  14. The development of an air injection system for the forced response testing of axial compressors

    CSIR Research Space (South Africa)

    Wegman, Erik J

    2013-06-01

    Full Text Available A phase-controllable, air injection exciter system was developed to enable measurement of the forced response properties of a transonic axial compressor blisk. The project was performed as part of the FP7 European framework program project FUTURE...

  15. The Development of Computer Code for Safety Injection Tank (SIT) with Fluidic Device(FD) Blowdown Test

    International Nuclear Information System (INIS)

    Lee, Joo Hee; Kim, Tae Han; Choi, Hae Yun; Lee, Kwang Won; Chung, Chang Kyu

    2007-01-01

    Safety Injection Tanks (SITs) with the Fluidic Device (FD) of APR1400 provides a means of rapid reflooding of the core following a large break Loss Of Coolant Accident (LOCA), and keeping it covered until flow from the Safety Injection Pump (SIP) becomes available. A passive FD can provide two operation stages of a safety water injection into the RCS and allow more effective use of borated water in case of LOCA. Once a large break LOCA occurs, the system will deliver a high flow rate of cooling water for a certain period of time, and thereafter, the flow rate is reduced to a lower flow rate. The conventional computer code 'TURTLE' used to simulate the blowdown of OPR1000 SIT can not be directly applied to simulate a blowdown process of the SIT with FD. A new computer code is needed to be developed for the blowdown test evaluation of the APR1400 SIT with FD. Korea Power Engineering Company (KOPEC) has developed a new computer code to analyze the characteristics of the SIT with FD and validated the code through the comparison of the calculation results with the test results obtained by Ulchin 5 and 6 units pre-operational test and VAlve Performance Evaluation Rig (VAPER) tests performed by The Korea Atomic Energy Research Institute (KAERI)

  16. Short-term static corrosion tests in lead-bismuth

    Science.gov (United States)

    Soler Crespo, L.; Martín Muñoz, F. J.; Gómez Briceño, D.

    2001-07-01

    Martensitic steels have been proposed to be used as structural materials and as spallation target window in hybrid systems devoted to the transmutation of radioactive waste of long life and high activity. However, their compatibility with lead-bismuth in the operating conditions of these systems depends on the existence of a protective layer such as an oxide film. The feasibility of forming and maintaining an oxide layer or maintaining a pre-oxidised one has been studied. Martensitic steel F82Hmod. (8% Cr) has been tested in lead-bismuth under static and isothermal conditions at 400°C and 600°C. In order to study the first stages of the interaction between the steel and the eutectic, short-term tests (100 and 665 h) have been carried out. Pre-oxidised and as-received samples have been tested in atmospheres with different oxidant potential. For low oxygen concentration in lead-bismuth due to unexpected oxygen consumption in the experimental device, dissolution of as-received F82Hmod. occurs and pre-oxidation does not prevent the material dissolution. For high oxygen concentration, the pre-oxidation layer seems to improve the feasibility of protecting stainless steels controlling the oxygen potential of lead-bismuth with a gas phase.

  17. Short-term static corrosion tests in lead-bismuth

    International Nuclear Information System (INIS)

    Soler Crespo, L.; Martin Munoz, F.J.; Gomez Briceno, D.

    2001-01-01

    Martensitic steels have been proposed to be used as structural materials and as spallation target window in hybrid systems devoted to the transmutation of radioactive waste of long life and high activity. However, their compatibility with lead-bismuth in the operating conditions of these systems depends on the existence of a protective layer such as an oxide film. The feasibility of forming and maintaining an oxide layer or maintaining a pre-oxidised one has been studied. Martensitic steel F82Hmod. (8% Cr) has been tested in lead-bismuth under static and isothermal conditions at 400 o C and 600 o C. In order to study the first stages of the interaction between the steel and the eutectic, short-term tests (100 and 665 h) have been carried out. Pre-oxidised and as-received samples have been tested in atmospheres with different oxidant potential. For low oxygen concentration in lead-bismuth due to unexpected oxygen consumption in the experimental device, dissolution of as-received F82Hmod. occurs and pre-oxidation does not prevent the material dissolution. For high oxygen concentration, the pre-oxidation layer seems to improve the feasibility of protecting stainless steels controlling the oxygen potential of lead-bismuth with a gas phase

  18. Single-well injection-withdrawal tests (SWIW). Investigation of evaluation aspects under heterogeneous crystalline bedrock conditions

    International Nuclear Information System (INIS)

    Nordqvist, Rune; Gustafsson, Erik

    2004-08-01

    Single-well injection-withdrawal (SWIW) tracer tests have been identified by SKB as an investigation method for solute transport properties in the forthcoming site investigations. A previous report presents a literature study as well as scoping calculations for SWIW tests in homogeneous crystalline bedrock environments. The present report comprises further scoping calculations under assumptions of heterogeneous bedrock conditions. Simple but plausible homogeneous evaluation models are tested on simulated SWIW tests in hypothetical heterogeneous two-dimensional fractures. The results from this study indicate that heterogeneity may cause effects of flow irreversibility when background hydraulic gradients are significant and the tested section is located in a dominating flow path. This implies that such conditions make it more difficult to interpret results from SWIW tests of longer duration with sorbing and/or diffusing tracers. Sorption and diffusion processes may be best studied when SWIW tests are conducted in borehole sections with low natural flow rates

  19. Surface Deformation Observed by InSAR due to Fluid Injection: a Test Study in the Central U.S.

    Science.gov (United States)

    Deng, F.; Dixon, T. H.

    2017-12-01

    The central and eastern U.S. has undergone a dramatic increase in seismicity over the past few years. Many of these recent earthquakes were likely induced by human activities, with underground fluid injection for oil and gas extraction being one of the main contributors. Surface deformation caused by fluid injection has been captured by GPS and InSAR observations in several areas. For example, surface uplift of up to 10 cm due to CO2 injection between 2007 and 2011 was measured by InSAR at an enhanced oil recovery site in west Texas. We are using Texas and Oklahoma as test areas to analyze the potential relationship between surface deformation, underground fluid injection and induced earthquakes. C-band SAR data from ENVISAT and Sentinel-1, and L-band SAR data from ALOS and ALOS-2 are used to form decade-long time series. Based on the surface deformation derived from the time series InSAR data, subsurface volume change and volumetric strain in an elastic half space are estimated. Seismic data provided by the USGS are used to analyze the spatial and temporal distribution pattern of earthquakes, and the potential link between surface deformation and induced earthquakes. The trigger mechanism will be combined with forward modeling to predict seismicity and assess related hazard for future study.

  20. The short- and medium-term effectiveness of CT-guided selective cervical nerve root injection for pain and disability

    Energy Technology Data Exchange (ETDEWEB)

    Desai, Amidevi; Saha, Shouvik; Sharma, Naveen; Huckerby, Lauren; Houghton, Russell [Guy' s and St. Thomas' Hospitals, Department of Radiology, London (United Kingdom)

    2014-07-15

    CT-guided cervical nerve root injection with corticosteroid and/or local anesthetic is a recognized technique in the evaluation and treatment of cervical radiculopathy. There are few prospective studies on the efficacy of the various techniques employed in cervical nerve root injection. We present our results from a 1-year prospective series using a CT-guided anterolateral transforaminal approach for cervical nerve root injection of bupivacaine and dexamethasone. Pain using a numeric rating scale was assessed at pre-injection, 15 min post-injection, 1 month, and 3 months. Disability was assessed using the Oswestry Neck Disability Index (NDI) questionnaire at pre-injection, 1 month post-injection, and 3 months. In total, 50 patients were followed for 3 months. The mean reductions in pain were: 15 min (77 %), 1 month (39 %), and 3 months (33 %). The mean reductions in NDI were: 1 month (26 %) and 3 months (also 26 %). Results were statistically significant. CT-guided selective cervical nerve root injection in the treatment of cervical radicular pain and related disability produces statistically significant reductions in pain and disability to at least 3 months post-procedure. (orig.)

  1. The short- and medium-term effectiveness of CT-guided selective cervical nerve root injection for pain and disability

    International Nuclear Information System (INIS)

    Desai, Amidevi; Saha, Shouvik; Sharma, Naveen; Huckerby, Lauren; Houghton, Russell

    2014-01-01

    CT-guided cervical nerve root injection with corticosteroid and/or local anesthetic is a recognized technique in the evaluation and treatment of cervical radiculopathy. There are few prospective studies on the efficacy of the various techniques employed in cervical nerve root injection. We present our results from a 1-year prospective series using a CT-guided anterolateral transforaminal approach for cervical nerve root injection of bupivacaine and dexamethasone. Pain using a numeric rating scale was assessed at pre-injection, 15 min post-injection, 1 month, and 3 months. Disability was assessed using the Oswestry Neck Disability Index (NDI) questionnaire at pre-injection, 1 month post-injection, and 3 months. In total, 50 patients were followed for 3 months. The mean reductions in pain were: 15 min (77 %), 1 month (39 %), and 3 months (33 %). The mean reductions in NDI were: 1 month (26 %) and 3 months (also 26 %). Results were statistically significant. CT-guided selective cervical nerve root injection in the treatment of cervical radicular pain and related disability produces statistically significant reductions in pain and disability to at least 3 months post-procedure. (orig.)

  2. Effects of single injection of local anesthetic agents on intervertebral disc degeneration: ex vivo and long-term in vivo experimental study.

    Directory of Open Access Journals (Sweden)

    Koji Iwasaki

    Full Text Available Analgesic discography (discoblock can be used to diagnose or treat discogenic low back pain by injecting a small amount of local anesthetics. However, recent in vitro studies have revealed cytotoxic effects of local anesthetics on intervertebral disc (IVD cells. Here we aimed to investigate the deteriorative effects of lidocaine and bupivacaine on rabbit IVDs using an organotypic culture model and an in vivo long-term follow-up model.For the organotypic culture model, rabbit IVDs were harvested and cultured for 3 or 7 days after intradiscal injection of local anesthetics (1% lidocaine or 0.5% bupivacaine. Nucleus pulposus (NP cell death was measured using confocal microscopy. Histological and TUNEL assays were performed. For in vivo study, each local anesthetic was injected into rabbit lumbar IVDs under a fluoroscope. Six or 12 months after the injection, each IVD was prepared for magnetic resonance imaging (MRI and histological analysis.In the organotypic culture model, both anesthetic agents induced time-dependent NP cell death; when compared with injected saline solution, significant effects were detected within 7 days. Compared with the saline group, TUNEL-positive NP cells were significantly increased in the bupivacaine group. In the in vivo study, MRI analysis did not show any significant difference. Histological analysis revealed that IVD degeneration occurred to a significantly level in the saline- and local anesthetics-injected groups compared with the untreated control or puncture-only groups. However, there was no significant difference between the saline and anesthetic agents groups.In the in vivo model using healthy IVDs, there was no strong evidence to suggest that discoblock with local anesthetics has the potential of inducing IVD degeneration other than the initial mechanical damage of the pressurized injection. Further studies should be performed to investigate the deteriorative effects of the local injection of analgesic agents

  3. Air-injection field tests to determine the effect of a heat cycle on the permeability of welded tuff

    International Nuclear Information System (INIS)

    Lee, K.H.; Ueng, Tzou-Shin.

    1991-01-01

    As part of a series of prototype tests conducted in preparation for site characterization of the potential nuclear-waste repository site at Yucca Mountain, Nevada, air-injection tests were conducted in the welded tuffs in G-Tunnel at the Nevada Test Site. The objectives were to characterize the permeability of the highly fractured tuff around a horizontal heater emplacement borehole, and to determine the effect of a heating and cooling cycle on the rock-mass permeability. Air was injected into packed-off intervals along the heater borehole. The bulk permeability of the rock adjacent to the test interval and the aperture of fractures intersecting the interval were computed from the air-flow rate, temperature, and pressure at steady state. The bulk permeability of intervals along with borehole varied from a minimum of 0.08 D to a maximum of over 144 D and the equivalent parallel-plate apertures of fractures intersecting the borehole varied from 70 to 589 μm. Higher permeabilities seemed to correlate spatially with the mapped fractures. The rock was then heated for a period of 6.5 months with an electrical-resistive heater installed in the borehole. After heating, the rock was allowed to cool down to the ambient temperature. The highest borehole wall temperature measured was 242 degree C. Air injection tests were repeated following the heating and cooling cycle, and the results showed significant increases in bulk permeability ranging from 10 to 1830% along the borehole. 8 ref., 6 figs., 3 tabs

  4. Long term safety, efficacy, and patient acceptability of hyaluronic acid injection in patients with painful osteoarthritis of the knee

    Science.gov (United States)

    McArthur, Benjamin A; Dy, Christopher J; Fabricant, Peter D; Valle, Alejandro Gonzalez Della

    2012-01-01

    The increasing prevalence of painful knee osteoarthritis has created an additional demand for pharmacologic management to prevent or delay surgical management. Viscosupplementation, via intraarticular injection of hyaluronic acid (HA), aims to restore the favorable milieu present in the nonarthritic joint. The safety profile of intraarticular HA injections for painful knee osteoarthritis is well established, with the most common adverse effect being a self-limited reaction at the injection site. Although acceptance of the early literature has been limited by publication bias and poor study quality, more recent and rigorous meta-analysis suggests that intraarticular HA injection is superior to placebo injection for pain relief and matches, if not surpasses, the effect size of other nonoperative treatments, such as nonsteroidal anti-inflammatory medication. Intraarticular HA injection is effective in providing temporary pain relief in patients with painful knee osteoarthritis. Future investigations should focus on optimizing the composition and administration of HA agents to provide prolonged relief of painful osteoarthritis in the knee and other joints. PMID:23271899

  5. Interim Report: 100-NR-2 Apatite Treatability Test: Low Concentration Calcium Citrate-Phosphate Solution Injection for In Situ Strontium-90 Immobilization

    Energy Technology Data Exchange (ETDEWEB)

    Williams, Mark D.; Fritz, Brad G.; Mendoza, Donaldo P.; Rockhold, Mark L.; Thorne, Paul D.; Xie, YuLong; Bjornstad, Bruce N.; Mackley, Rob D.; Newcomer, Darrell R.; Szecsody, James E.; Vermeul, Vincent R.

    2008-07-11

    Following an evaluation of potential Sr-90 treatment technologies and their applicability under 100-NR-2 hydrogeologic conditions, U.S. Department of Energy, Fluor Hanford, Inc., Pacific Northwest National Laboratory, and the Washington Department of Ecology agreed that the long-term strategy for groundwater remediation at 100-N Area will include apatite sequestration as the primary treatment, followed by a secondary treatment if necessary (most likely phytoremediation). Since then, the agencies have worked together to agree on which apatite sequestration technology has the greatest chance of reducing Sr-90 flux to the river at a reasonable cost. In July 2005, aqueous injection, (i.e., the introduction of apatite-forming chemicals into the subsurface) was endorsed as the interim remedy and selected for field testing. Studies are in progress to assess the efficacy of in situ apatite formation by aqueous solution injection to address both the vadose zone and the shallow aquifer along the 300 ft of shoreline where Sr-90 concentrations are highest. This report describes the field testing of the shallow aquifer treatment.

  6. Acceptability of rapid oral fluid HIV testing among male injection drug users in Taiwan, 1997 and 2007.

    Science.gov (United States)

    Lyu, Shu-Yu; Morisky, Donald E; Yeh, Ching-Ying; Twu, Shiing-Jer; Peng, Eugene Yu-Chang; Malow, Robert M

    2011-04-01

    Rapid oral fluid HIV testing (rapid oral testing) is in the process of being adapted in Taiwan and elsewhere given its advantages over prior HIV testing methods. To guide this process, we examined the acceptability of rapid oral testing at two time points (i.e., 1997 and 2007) among one of the highest risk populations, male injection drug users (IDUs). For this purpose, an anonymous self-administered survey was completed by HIV-negative IDUs involved in the criminal justice system in 1997 (N (1)=137 parolees) and 2007 (N (2)=106 prisoners). A social marketing model helped guide the design of our questionnaire to assess the acceptability of rapid oral testing. This included assessing a new product, across four marketing dimensions: product, price, promotion, and place. Results revealed that in both 1997 and 2007, over 90% indicated that rapid oral testing would be highly acceptable, particularly if the cost was under US$6, and that a pharmacy would be the most appropriate and accessible venue for selling the rapid oral testing kits. The vast majority of survey respondents believed that the cost of rapid oral testing should be federally subsidized and that television and newspaper advertisements would be the most effective media to advertise for rapid oral testing. Both the 1997 and 2007 surveys suggested that rapid oral HIV testing would be particularly accepted in Taiwan by IDUs after release from the criminal justice system.

  7. Labeling of hepatic glycogen after short- and long-term stimulation of glycogen synthesis in rats injected with 3H-galactose

    International Nuclear Information System (INIS)

    Michaels, J.E.; Garfield, S.A.; Hung, J.T.; Cardell, R.R. Jr.

    1990-01-01

    The effects of short- and long-term stimulation of glycogen synthesis elicited by dexamethasone were studied by light (LM) and electron (EM) microscopic radioautography (RAG) and biochemical analysis. Adrenalectomized rats were fasted overnight and pretreated for short- (3 hr) or long-term (14 hr) periods with dexamethasone prior to intravenous injection of tracer doses of 3H-galactose. Analysis of LM-RAGs from short-term rats revealed that about equal percentages (44%) of hepatocytes became heavily or lightly labeled 1 hr after labeling. The percentage of heavily labeled cells increased slightly 6 hr after labeling, and unlabeled glycogen became apparent in some hepatocytes. The percentage of heavily labeled cells had decreased somewhat 12 hr after labeling, and more unlabeled glycogen was evident. In the long-term rats 1 hr after labeling, a higher percentage of heavily labeled cells (76%) was observed compared to short-term rats, and most glycogen was labeled. In spite of the high amount of labeling seen initially, the percentage of heavily labeled hepatocytes had decreased considerably to 55% by 12 hr after injection; and sparsely labeled and unlabeled glycogen was prevalent. The EM-RAGs of both short- and long-term rats were similar. Silver grains were associated with glycogen patches 1 hr after labeling; 12 hr after labeling, the glycogen patches had enlarged; and label, where present, was dispersed over the enlarged glycogen clumps. Analysis of DPM/mg tissue corroborated the observed decrease in label 12 hr after administration in the long-term animals. The loss of label observed 12 hr after injection in the long-term pretreated rats suggests that turnover of glycogen occurred during this interval despite the net accumulation of glycogen that was visible morphologically and evident from biochemical measurement

  8. Sector Tests of a Low-NO(sub x), Lean, Direct- Injection, Multipoint Integrated Module Combustor Concept Conducted

    Science.gov (United States)

    Tacina, Robert R.; Wey, Chang-Lie; Laing, Peter; Mansour, Adel

    2002-01-01

    The low-emissions combustor development described is directed toward advanced high pressure aircraft gas-turbine applications. The emphasis of this research is to reduce nitrogen oxides (NOx) at high-power conditions and to maintain carbon monoxide and unburned hydrocarbons at their current low levels at low power conditions. Low-NOx combustors can be classified into rich-burn and lean-burn concepts. Lean-burn combustors can be further classified into lean-premixed-prevaporized (LPP) and lean direct injection (LDI) concepts. In both concepts, all the combustor air, except for liner cooling flow, enters through the combustor dome so that the combustion occurs at the lowest possible flame temperature. The LPP concept has been shown to have the lowest NOx emissions, but for advanced high-pressure-ratio engines, the possibility of autoignition or flashback precludes its use. LDI differs from LPP in that the fuel is injected directly into the flame zone, and thus, it does not have the potential for autoignition or flashback and should have greater stability. However, since it is not premixed and prevaporized, good atomization is necessary and the fuel must be mixed quickly and uniformly so that flame temperatures are low and NOx formation levels are comparable to those of LPP. The LDI concept described is a multipoint fuel injection/multiburning zone concept. Each of the multiple fuel injectors has an air swirler associated with it to provide quick mixing and a small recirculation zone for burning. The multipoint fuel injection provides quick, uniform mixing and the small multiburning zones provide for reduced burning residence time, resulting in low NOx formation. An integrated-module approach was used for the construction where chemically etched laminates, diffusion bonded together, combine the fuel injectors, air swirlers, and fuel manifold into a single element. The multipoint concept combustor was demonstrated in a 15 sector test. The configuration tested had 36

  9. LHI (low head safety injection) emergency cooling pump test for the EPR trademark in operation with solid matter loaded water

    International Nuclear Information System (INIS)

    Ganzmann, I.; Schulte, C.

    2010-01-01

    Emergency cooling pumps are essential and indispensable components of the NPP safety philosophy. In case of a loss-of coolant accident solid matter (debris: fibrous insulation material, concrete dust, pigment particles) might be released into the coolant, LHSI (low head safety injection) pumps have to ensure their performance capacity for a certain amount of debris without damage or loss of power. The authors describe the development of a test facility. The LHSI was tested in continuous operation over a time period of 14 days with a debris content of 1500 ppm (90% mineral wool fibers, 3% concrete dust, 3% pigment particles, 4% microporous insulation material). The pump did not show any damage or loss of hydraulic power. Further tests including thermoshock conditions (temperature changes of 160 C) are planned.

  10. Performance of ARCHITECT HCV core antigen test with specimens from US plasma donors and injecting drug users.

    Science.gov (United States)

    Mixson-Hayden, Tonya; Dawson, George J; Teshale, Eyasu; Le, Thao; Cheng, Kevin; Drobeniuc, Jan; Ward, John; Kamili, Saleem

    2015-05-01

    Hepatitis C virus (HCV) core antigen is a serological marker of current HCV infection. The aim of this study was mainly to evaluate the performance characteristics of the ARCHITECT HCV core antigen assay with specimens from US plasma donors and injecting drug users. A total of 551 serum and plasma samples with known anti-HCV and HCV RNA status were tested for HCV core antigen using the Abbott ARCHITECT HCV core antigen test. HCV core antigen was detectable in 100% of US plasma donor samples collected during the pre-seroconversion phase of infection (anti-HCV negative/HCV RNA positive). Overall sensitivity of the HCV core antigen assay was 88.9-94.3% in samples collected after seroconversion. The correlation between HCV core antigen and HCV RNA titers was 0.959. HCV core antigen testing may be reliably used to identify current HCV infection. Published by Elsevier B.V.

  11. Two-dimensional thermal-hydraulic behavior in core in SCTF Core-II cold leg injection tests

    International Nuclear Information System (INIS)

    Iwamura, Takamichi; Sobajima, Makoto; Okubo, Tsutomu; Ohnuki, Akira; Abe, Yutaka; Adachi, Hiromichi

    1985-07-01

    Major purpose of the Slab Core Test Program is to investigate the two-dimensional thermal-hydraulic behavior in the core during the reflood phase in a PWR-LOCA. In order to investigate the effects of radial power profile, three cold leg injection tests with different radial power profiles under the same total heating power and core stored energy were performed by using the Slab Core Test Facility (SCTF) Core-II. It was revealed by comparing these three tests that the heat transfer was enhanced in the higher power bundles and degraded in the lower power bundles in the non-uniform radial power profile tests. The turnaround temperature in the high power bundles were evaluated to be reduced by about 40 to 120 K. On the other hand, a two-dimensional flow in the core was also induced by the non-uniform water accumulation in the upper plenum and the quench was delayed resultantly in the bundles corresponding to the peripheral bundles of a PWR. However, the effect of the non-uniform upper plenum water accumulation on the turnaround temperature was small because the effect dominated after the turnaround of the cladding temperature. Selected data from Tests S2-SH1, S2-SH2 and S2-O6 are also presented in this report. Some data from Tests S2-SH1 and S2-SH2 were compared with TRAC post-test calculations performed by the Los Alamos National Laboratory. (author)

  12. Information contained within the large scale gas injection test (Lasgit) dataset exposed using a bespoke data analysis tool-kit

    International Nuclear Information System (INIS)

    Bennett, D.P.; Thomas, H.R.; Cuss, R.J.; Harrington, J.F.; Vardon, P.J.

    2012-01-01

    Document available in extended abstract form only. The Large Scale Gas Injection Test (Lasgit) is a field scale experiment run by the British Geological Survey (BGS) and is located approximately 420 m underground at SKB's Aespoe Hard Rock Laboratory (HRL) in Sweden. It has been designed to study the impact on safety of gas build up within a KBS-3V concept high level radioactive waste repository. Lasgit has been in almost continuous operation for approximately seven years and is still underway. An analysis of the dataset arising from the Lasgit experiment with particular attention to the smaller scale features and phenomenon recorded has been undertaken in parallel to the macro scale analysis performed by the BGS. Lasgit is a highly instrumented, frequently sampled and long-lived experiment leading to a substantial dataset containing in excess of 14.7 million datum points. The data is anticipated to include a wealth of information, including information regarding overall processes as well as smaller scale or 'second order' features. Due to the size of the dataset coupled with the detailed analysis of the dataset required and the reduction in subjectivity associated with measurement compared to observation, computational analysis is essential. Moreover, due to the length of operation and complexity of experimental activity, the Lasgit dataset is not typically suited to 'out of the box' time series analysis algorithms. In particular, the features that are not suited to standard algorithms include non-uniformities due to (deliberate) changes in sample rate at various points in the experimental history and missing data due to hardware malfunction/failure causing interruption of logging cycles. To address these features a computational tool-kit capable of performing an Exploratory Data Analysis (EDA) on long-term, large-scale datasets with non-uniformities has been developed. Particular tool-kit abilities include: the parameterization of signal variation in the dataset

  13. Model complexity and choice of model approaches for practical simulations of CO2 injection, migration, leakage and long-term fate

    Energy Technology Data Exchange (ETDEWEB)

    Celia, Michael A. [Princeton Univ., NJ (United States)

    2016-12-30

    This report documents the accomplishments achieved during the project titled “Model complexity and choice of model approaches for practical simulations of CO2 injection,migration, leakage and long-term fate” funded by the US Department of Energy, Office of Fossil Energy. The objective of the project was to investigate modeling approaches of various levels of complexity relevant to geologic carbon storage (GCS) modeling with the goal to establish guidelines on choice of modeling approach.

  14. Long-term follow-up after neoplastic seeding complicating percutaneous ethanol injection for treatment of hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Arrive, L.; Vurgait, A.; Monnier-Cholley, L.; Lewin, M.; Tubiana, J.M.; Balladur, P.; Poupon, R.

    2002-01-01

    We describe a case of subcutaneous metastasis along the needle track after percutaneous ethanol injection (PEI) for treatment of hepatocellular carcinoma. After surgical resection and extrabeam radiation therapy the patient is alive without evidence of recurrence five years after PEI. One should pay attention to the abdominal wall around the needle track in interpreting CT or MR images of patients with previous PEI. (orig.)

  15. Endoscopic Injection of Dextranomer/Hyaluronic Acid as First-Line Treatment in 851 Consecutive Children with High-Grade Vesicoureteral Reflux: Efficacy and Long-Term Results.

    Science.gov (United States)

    Friedmacher, Florian; Colhoun, Eric; Puri, Prem

    2018-03-15

    Endoscopic injection of dextranomer/hyaluronic is widely acknowledged as first-line treatment of lower grade vesicoureteral reflux. Our objective was to demonstrate its long-term efficacy and safety in eradicating high-grade reflux. Eight-hundred-fifty-one children (518 girls, 333 boys), median age 2.3 years (2 months-13.7 years), underwent endoscopic correction of high-grade vesicoureteral reflux using dextranomer/hyaluronic acid. Reflux was unilateral in 415 cases and bilateral in 436, comprising 1,287 refluxing units: grade IV in 1,153 (89.6%) and grade V in 134 (10.4%). 99m technetium-dimercaptosuccinic acid imaging identified renal scarring in 317 (37.3%) patients. Follow-up ultrasound and voiding cystourethrogram were performed 3 months post intervention and renal ultrasound annually thereafter. Median follow-up was 8.5 years (6 months-16 years). Overall resolution rate after the first endoscopic injection was 895/1,287 (69.5%): 70.4% in grade IV and 61.9% in grade V, respectively. Reflux resolved after a second injection in 259 (20.1%) and after a third in 133 (10.4%). Persistent reflux after initial treatment was significantly more common in infants reflux resolution, 43 (5.1%) children developed febrile urinary tract infections: 24 (55.8%) in the first, 15 (34.9%) in the second and 4 (9.3%) after ≥3 years. Of these, 6 had reflux recurrence and 8 demonstrated neocontralateral grade III reflux, which was successfully treated with single endoscopic injection of dextranomer/hyaluronic acid. Endoscopic injection of dextranomer/hyaluronic acid is an efficient and safe long-term treatment for grade IV and V vesicoureteral reflux, which can be easily repeated in cases of failure with a high subsequent resolution rate. Copyright © 2018 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  16. Regulatory Guide 1.79 safety injection recirculation test requirements, fact or fiction

    International Nuclear Information System (INIS)

    Roberts, J.K.

    1976-01-01

    The overwhelming concern of the general public in this day of state nuclear initiatives is the basic question, ''is nuclear power safe.'' Much of this concern has focused on the emergency core cooling systems. This public attention spotlights the testing organization's responsibility during startup of proving the operation and reliability of the emergency core cooling systems. The standard established by the Nuclear Regulatory Commission for testing emergency core cooling systems is Regulatory Guide 1.79 ''Preoperational Testing of Emergency Core Cooling Systems for Pressurized Water Reactors''. The nuclear industry must satisfy the testing requirements of Regulatory Guide 1.79 to meet their responsibility to the public; and to prevent future embarrassment when questioned on the adequacy of emergency core cooling systems

  17. Depletion of penicillin G residues in heavy sows after intramuscular injection. Part II: application of kidney inhibition swab tests.

    Science.gov (United States)

    Shelver, Weilin L; Lupton, Sara J; Newman, David J; Larsen, Steven; Smith, David J

    2014-07-30

    Sows (n = 126; 228 ± 30.1 kg) were administered daily IM doses of penicillin G procaine (33 000 IU/kg bw; 5× the label dose) for 3 consecutive days using three different administration patterns. Within treatment, six sows each were slaughtered on withdrawal day 5, 10, 15, 20, 25, 32, and 39. Tissues (injection site, kidney, liver, skeletal muscle) or body fluids (serum and urine) were screened for penicillin G using the KIS test, recently adopted by the USDA Food Safety and Inspection Service. The IM administration patterns had no discernible effect on penicillin G depletion. Residues were depleted more rapidly from liver and skeletal muscle and more slowly from kidney and urine. Kidney was the most sensitive and suitable tissue for detecting penicillin G residues on-site, with two positive results after a 39-day withdrawal period. Urine was the most suitable ante-mortem surrogate to predict the results of kidney tests.

  18. Testing and modelling of a novel oil-free co-rotating scroll machine with water injection

    International Nuclear Information System (INIS)

    Mendoza, Luis Carlos; Lemofouet, Sylvain; Schiffmann, Jürg

    2017-01-01

    Highlights: • Performance of novel oil-free co-rotating scroll expander presented. • Water injection allows reaching quasi-isothermal expansion process. • Comparison between experimental data, semi-empirical and deterministic models. • Flank leakage, water injection and rotor speed effects have been analyzed experimentally. • Design guidelines for co-rotating scroll improvement proposed. - Abstract: Efficient compressed air energy storage requires reversible isothermal compression and expansion devices. The isothermal compression and expansion processes can either be approached by several stages with intercooling or by the more convenient injection of a liquid, often water. While volumetric machines are readily available for dry processes the compression and expansion of a gas with the presence of liquid is still problematic. The concept of a co-rotating scroll has been identified as a promising technology to cope with the presence of liquid. The current paper discusses the first experimental results of an oil-free co-rotating scroll prototype tested in expansion mode on a wide range of rotational speeds, varying water injection flow rates and with different nominal flank clearances. A maximal overall isothermal efficiency of 34% and a maximum output power of 1.74 kW_e_l were measured with this first prototype, providing the proof of the technical feasibility of the oil-free co-rotating scroll expander concept. The experimental data indicate a positive effect of water injection suggesting good heat transfer behaviour between the water and the air in the individual chambers, which is a result of the relatively long residence time compared to other volumetric concepts. The experimental sensitivity analysis yields a strong dependency of the machine performance on both the nominal flank clearance and on the injected water rate. The analysis through a semi-empirical model suggests the inversion of a classical trend, i.e. the increase in total leakage area with

  19. Long-term creep test with finite elements

    International Nuclear Information System (INIS)

    Argyris, J.H.; Szimmat, J.; Willam, K.J.

    1975-01-01

    Following a presentation of concrete creep, a brief summary of the direct and incremental calculation methods for long-term creep behaviour is given. In addition, a survey on the methods of the inner state variables is given which, on the one hand, gives a uniform framework for the various formulations of concrete creep, and on the other hand leads to a computable calculation method. Two examples on long-term creep behaviour illustrate the application field of the calculation method. (orig./LH) [de

  20. Comparison of MELCOR modeling techniques and effects of vessel water injection on a low-pressure, short-term, station blackout at the Grand Gulf Nuclear Station

    International Nuclear Information System (INIS)

    Carbajo, J.J.

    1995-06-01

    A fully qualified, best-estimate MELCOR deck has been prepared for the Grand Gulf Nuclear Station and has been run using MELCOR 1.8.3 (1.8 PN) for a low-pressure, short-term, station blackout severe accident. The same severe accident sequence has been run with the same MELCOR version for the same plant using the deck prepared during the NUREG-1150 study. A third run was also completed with the best-estimate deck but without the Lower Plenum Debris Bed (BH) Package to model the lower plenum. The results from the three runs have been compared, and substantial differences have been found. The timing of important events is shorter, and the calculated source terms are in most cases larger for the NUREG-1150 deck results. However, some of the source terms calculated by the NUREG-1150 deck are not conservative when compared to the best-estimate deck results. These results identified some deficiencies in the NUREG-1150 model of the Grand Gulf Nuclear Station. Injection recovery sequences have also been simulated by injecting water into the vessel after core relocation started. This marks the first use of the new BH Package of MELCOR to investigate the effects of water addition to a lower plenum debris bed. The calculated results indicate that vessel failure can be prevented by injecting water at a sufficiently early stage. No pressure spikes in the vessel were predicted during the water injection. The MELCOR code has proven to be a useful tool for severe accident management strategies

  1. Safe and successful endoscopic initial treatment and long-term eradication of gastric varices by endoscopic ultrasound-guided Histoacryl (N-butyl-2-cyanoacrylate) injection.

    Science.gov (United States)

    Gubler, Christoph; Bauerfeind, Peter

    2014-09-01

    Optimal endoscopic treatment of gastric varices is still not standardized nowadays. Actively bleeding varices may prohibit a successful endoscopic injection therapy of Histoacryl® (N-butyl-2-cyanoacrylate). Since 2006, we have treated gastric varices by standardized endoscopic ultrasound (EUS) guided Histoacryl injection therapy without severe adverse events. We present a large single-center cohort over 7 years with a standardized EUS-guided sclerotherapy of all patients with gastric varices. Application was controlled by fluoroscopy to immediately detect any glue embolization. Only perforating veins located within the gastric wall were treated. In the follow up, we repeated this treatment until varices were eradicated. Utmost patients (36 of 40) were treated during or within 24 h of active bleeding. About 32.5% of patients were treated while visible bleeding. Histoacryl injection was always technically successful and only two patients suffered a minor complication. Acute bleeding was stopped in all patients. About 15% (6 of 40) of patients needed an alternative rescue treatment in the longer course. Three patients got a transjugular portosystemic shunt and another three underwent an orthotopic liver transplantation. Mean long-term survival of 60 months was excellent. Active bleeding of gastric varices can be treated successfully without the necessity of gastric rinsing with EUS-guided injection of Histoacryl.

  2. Effectiveness of a short-term treatment with progesterone injections on synchrony of lambing and fertility in tropical hair sheep.

    Science.gov (United States)

    Knights, Marlon; Ramgattie, Reeza; Siew, Narendra; Singh-Knights, Doolarie; Bourne, Gregory

    2011-06-01

    The efficacy of using a low cost system for delivering progesterone as part of an estrous synchronization protocol in sheep was evaluated. In experiment 1, Barbados Black Belly ewes (n=34) and ewe lambs (n=35; 37.5±0.9 kg) were assigned to be untreated, control animals (C), or to receive PGF(2α) on d0 (PG), or receive two injections of progesterone (200mg, i.m. each) on D -5 and on D -2.5, prior to PGF(2α), on D 0 (2PPG). Treatment with 2PPG increased the proportion of animals lambing to the first service (Psynchronized regardless of physiological state. In conclusion, the two-progesterone injection synchronization protocol may be used as a practical low cost and efficient method of synchronizing estrus to reduce the lambing interval and maximize productivity in tropical breeds of sheep. Copyright © 2011 Elsevier B.V. All rights reserved.

  3. Antigen injection (image)

    Science.gov (United States)

    Leprosy is caused by the organism Mycobacterium leprae . The leprosy test involves injection of an antigen just under ... if your body has a current or recent leprosy infection. The injection site is labeled and examined ...

  4. ROTARY FUEL INJECTION PUMP WEAR TESTING USING A 30 %/ 70% ATJ/F-24 FUEL BLEND

    Science.gov (United States)

    2017-09-30

    DD-MM-YYYY) 30-09-2017 2. REPORT TYPE Interim Report 3. DATES COVERED (From - To) September 2013 – September 2017 4. TITLE AND SUBTITLE Rotary... Corrosion Inhibitor/Lubricity Improver cm...fuels, to full scale equipment and fleet testing to determine resulting component and vehicle performance. This report covers investigation into the

  5. A new apparatus and method for mixing solutes for injection tests

    African Journals Online (AJOL)

    2009-07-17

    Jul 17, 2009 ... ISSN 1816-7950 (On-line) = Water SA Vol. 37 No. 2 April 2011 ... the push-pull test, a tracer is introduced to the standing water .... the assembly leak-proof. ..... ment of Rural Water Supply Management Strategies for Secondary.

  6. Preparation and evaluation of a phospholipid-based injectable gel for the long term delivery of leuprolide acetaterrh.

    Science.gov (United States)

    Long, Danhong; Gong, Tao; Zhang, Zhirong; Ding, Rui; Fu, Yao

    2016-07-01

    A phospholipid-based injectable gel was developed for the sustained delivery of leuprolide acetate (LA). The gel system was prepared using biocompatible materials (SPME), including soya phosphatidyl choline (SPC), medium chain triglyceride (MCT) and ethanol. The system displayed a sol state with low viscosity in vitro and underwent in situ gelation in vivo after subcutaneous injection. An in vitro release study was performed using a dialysis setup with different release media containing different percentages of ethanol. The stability of LA in the SPME system was investigated under different temperatures and in the presence of various antioxidants. In vivo studies in male rats were performed to elucidate the pharmacokinetic profiles and pharmacodynamic efficacy. A sustained release of LA for 28 days was observed without obvious initial burst in vivo. The pharmacodynamic study showed that once-a-month injection of LA-loaded SPME (SPME-LA) led to comparable suppression effects on the serum testosterone level as observed in LA solution except for the onset time. These findings demonstrate excellent potential for this novel SPME system as a sustained release delivery system for LA.

  7. Preparation and evaluation of a phospholipid-based injectable gel for the long term delivery of leuprolide acetaterrh

    Directory of Open Access Journals (Sweden)

    Danhong Long

    2016-07-01

    Full Text Available A phospholipid-based injectable gel was developed for the sustained delivery of leuprolide acetate (LA. The gel system was prepared using biocompatible materials (SPME, including soya phosphatidyl choline (SPC, medium chain triglyceride (MCT and ethanol. The system displayed a sol state with low viscosity in vitro and underwent in situ gelation in vivo after subcutaneous injection. An in vitro release study was performed using a dialysis setup with different release media containing different percentages of ethanol. The stability of LA in the SPME system was investigated under different temperatures and in the presence of various antioxidants. In vivo studies in male rats were performed to elucidate the pharmacokinetic profiles and pharmacodynamic efficacy. A sustained release of LA for 28 days was observed without obvious initial burst in vivo. The pharmacodynamic study showed that once-a-month injection of LA-loaded SPME (SPME-LA led to comparable suppression effects on the serum testosterone level as observed in LA solution except for the onset time. These findings demonstrate excellent potential for this novel SPME system as a sustained release delivery system for LA.

  8. Long-term study of liver damage following subcutaneous injection of airborne particle extracts and polycyclic aromatic hydrocarbon fractions

    Energy Technology Data Exchange (ETDEWEB)

    Meiss, R.; Heinrich, U.; Offermann, M.; Themann, H.

    1982-02-01

    Female NMRI mice aged 9-12 weeks were each given a single subcutaneous injection of 0.5 ml of a suspension containing either the total extracts or the polycyclic aromatic hydrocarbon (PAH) fraction of airborne particles. Both the total extracts and PAH fractions contain 3 microgram benzopyrene. After about 15 months the livers were removed from the animals, which had by that time developed tumors at the injection site, and were subjected to electron-microscopical study. The essential alterations were observed in the nucleoli and the cell nuclei, which had greatly proliferated and exhibited irregular nuclear membranes. Advanced fibrosis was observed in central liver specimens of all groups. Marked alterations were also observed in the mitochondria and the mitochondrial cristae as well as in the bile canaliculi, Intracytoplasmic glycogen usually occurred densely clustered along the periphery of the cell. It may be concluded from the observations that both the total extract of atmospheric suspended particulate matter and the PAH fraction cause hematogenic damage to the liver following subcutaneous injection, a finding which cannot be interpreted as metastatic carcinoma.

  9. Long-term study of liver damage following subcutaneous injection of airborne particle extracts and polycyclic aromatic hydrocarbon fractions

    Energy Technology Data Exchange (ETDEWEB)

    Meiss, R.; Heinrich, U.; Offermann, M.; Themann, H.

    1982-02-01

    Female NMRI mice aged 9-12 weeks were each given a single subcutaneous injection of 0.5 ml of a suspension containing either the total extracts or the polycyclic aromatic hydrocarbon (PAH) fraction of airborne particles. Both the total extracts and PAH fractions contain 3 ..mu..g benzopyrene. After about 15 months the livers were removed from the animals, which had by that time developed tumors at the injection site, and were subjected to electron-microscopical study. The essential alterations were observed in the nucleoli and the cell nuclei, which had greatly proliferated and exhibited irregular nuclear membranes. Advanced fibrosis was observed in central liver specimens of all groups. Marked alterations were also observed in the mitochondria and the mitochondrial cristae as well as in the bile canaliculi. Intracytoplasmic glycogen usually occurred densely clustered along the periphery of the cell. It may be concluded from the observations that both the total extract of atmospheric suspended particulate matter and the PAH fraction cause hematogenic damage to the liver following subcutaneous injection, a finding which cannot be interpreted as metastatic carcinoma.

  10. Dry blood spot testing for hepatitis C in people who injected drugs: reaching the populations other tests cannot reach.

    Science.gov (United States)

    Tait, J M; Stephens, Brian P; McIntyre, Paul G; Evans, Morgan; Dillon, John F

    2013-10-01

    The aim of the study was to evaluate the effectiveness of Dry Blood Spot testing (DBST) for hepatitis C within a geographical area. This is a prospective cohort study of all individuals living in Tayside who had received a hepatitis C virus (HCV) DBST between 2009 and 2011. During the study, 1123 DBSTs were carried out. 946 individuals had one test. 295 (31.2%) of these individuals were HCV antibody positive on their first test. Overall, 94.3% (902/956) individuals returned for the results of their test. During the course of the study 177 individuals were retested and 29 new cases of hepatitis C were detected. 249 individuals attended for further follow-up, and 164 (65.5%) were PCR positive. All 164 PCR-positive individuals were offered referral into specialist HCV services for further assessment. Data showed 62.5% were genotype 3, 65.1% had a low viral load (<600 000 iu/ml) and 77.5% had a Fibroscan score below 7 KPa. To date, 40 have commenced treatment and a further 16 are currently in the assessment period. Overall, we have retained in services or treated 63.6% (105/164) of patients who were initially referred and with effective support mechanisms in place we have achieved sustained viral response rates of 90%. The study has shown that DBST is a complementary technique to conventional venepuncture for the diagnosis of HCV. The majority of patients have low viral loads and low fibrosis scores, so that while this group of patients may be difficult to reach and may be challenging to maintain in therapy, they are easier to cure.

  11. Long-term correction of obesity and diabetes in genetically obese mice by a single intramuscular injection of recombinant adeno-associated virus encoding mouse leptin

    Science.gov (United States)

    Murphy, John E.; Zhou, Shangzhen; Giese, Klaus; Williams, Lewis T.; Escobedo, Jaime A.; Dwarki, Varavani J.

    1997-01-01

    The ob/ob mouse is genetically deficient in leptin and exhibits a phenotype that includes obesity and non-insulin-dependent diabetes melitus. This phenotype closely resembles the morbid obesity seen in humans. In this study, we demonstrate that a single intramuscular injection of a recombinant adeno-associated virus (AAV) vector encoding mouse leptin (rAAV-leptin) in ob/ob mice leads to prevention of obesity and diabetes. The treated animals show normalization of metabolic abnormalities including hyperglycemia, insulin resistance, impaired glucose tolerance, and lethargy. The effects of a single injection have lasted through the 6-month course of the study. At all time points measured the circulating levels of leptin in the serum were similar to age-matched control C57 mice. These results demonstrate that maintenance of normal levels of leptin (2–5 ng/ml) in the circulation can prevent both the onset of obesity and associated non-insulin-dependent diabetes. Thus a single injection of a rAAV vector expressing a therapeutic gene can lead to complete and long-term correction of a genetic disorder. Our study demonstrates the long-term correction of a disease caused by a genetic defect and proves the feasibility of using rAAV-based vectors for the treatment of chronic disorders like obesity. PMID:9391128

  12. Experiments on the behaviour of thermite melt injected into sodium: Final report on the THINA test results

    International Nuclear Information System (INIS)

    Huber, F.; Kaiser, A.; Peppler, W.

    1994-01-01

    During hypothetical accidents of fast breeder reactors the core melts and part of the core material inventory is ejected into the upper coolant plenum. As a consequence, a fuel to coolant thermal interaction occurs between the melt and the sodium. A series of simulating experiments was carried out in KfK/IRS to improve the knowledge about the phenomenology of molten fuel/coolant interactions and to support theoretical work on the safety of fast breeder reactors. In the tests, a thermite melt of up to 3270 K is injected from below into a sodium pool the temperature of which is between 770 and 820 K. The masses of the melt and the sodium are about five and 150 kg, respectively. Thermal interactions have been observed to occur as a sequence of small local pressure events mainly during the melt injection. Large-scale vapour explosions have not been observed. Generally, the conversion ratios of thermal to mechanical energy have been low. (author)

  13. Construction and 60 kV tests of the prototype pulser for the LHC injection kicker system

    CERN Document Server

    Barnes, M J; Carlier, E; Ducimetière, L; Schröder, G; Vossenberg, Eugène B

    1999-01-01

    The European Laboratory for Particle Physics (CERN) is constructing the Large Hadron Collider (LHC). Two counter-rotating proton beams will be injected into the LHC at an energy of 450 GeV by two kicker magnet systems, producing magnetic field pulses of approximately 900 ns rise time and 6.6 mu s flat top duration with a ripple of less than +or-0.5Both injection systems are composed of 4 travelling wave kicker magnets of 2.17 m length each, powered by pulse forming networks (PFNs). To achieve the high-required kick strength of 1.2 Tm, for a compact and cost efficient design, a characteristic impedance of 5 Ohms has been chosen. The design strategy for the magnets and generators has been defined after detailed analysis of existing systems. The electrical circuit has been optimised using the circuit analysis software PSpice. Most known parasitics have been modelled. A prototype PFN has been constructed at CERN and successfully tested at 60 kV. A calibration procedure has been developed and utilised for obtainin...

  14. Collagenase injections for the treatment of single cords in cases of Dupuytren’s contracture – a prospective intervention study of long-term experience with Xiapex

    Directory of Open Access Journals (Sweden)

    Fischer, Lisa Maria

    2017-04-01

    Full Text Available Introduction: The gold standard in the treatment of Dupuytren’s contracture is surgical therapy. Alternatives are percutaneous needle fasciotomy and radiation in exceptional cases. Injection treatments with Xiapex (Pfizer are a new therapy option. This collagenase, extracted from clostridium histolyticum, is used to break down the affected tissue cords. The objective of this study is to examine the effect and long-term success of treatment with Xiapex.Methods: In this study, Xiapex treatment was conducted on a sample group of 19 patients with Dupuytren’s contracture. The injection was placed either on the cord at the level of the metacarpophalangeal (MCP joint (n=17 or of the proximal interphalangeal (PIP joint (n=7. Break-up of the cord occurred 24 hours after the injection. The neutral zero method was used to assess the extent of movement. The Michigan Hand Outcomes Questionnaire (MHQ was selected for evaluation of the general hand function in 16 patients. The WHO-5 and the EQ-5D VAS Score were used as a measure of the patients’ satisfaction and their state of health. All values were collected both pre-injection as well as 1 year post-injection.Results: Out of 19 patients in our sample group, 16 patients (≈84% benefitted in terms of improvement in mobility. Overall, the range of movement increased by Ø 26° in the affected finger. A separate assessment demonstrated that:The range of movement increased by 77% in the MCP joint. The extent of movement pre-injection was Ø (0-28-78 and post-injection it was Ø (0-9-81 with an improvement of Ø 22°. In the PIP joint, only slight improvement was observed (Ø pre (0-27-93; post (0-24-95.The MHQ increased from Ø 76% (R: 32–97% to 81% (R: 39–100%.The painfulness decreased from Ø 19% (R: 0–55% to Ø11% (R: 0–55%, corresponding to Ø 43%. Satisfaction increased in 72% of patients by Ø 21%.According to WHO-5, patient satisfaction pre-injection was Ø 20 (R: 11–25, and 1 year after

  15. MK-801 and memantine act differently on short-term memory tested with different time-intervals in the Morris water maze test.

    Science.gov (United States)

    Duda, Weronika; Wesierska, Malgorzata; Ostaszewski, Pawel; Vales, Karel; Nekovarova, Tereza; Stuchlik, Ales

    2016-09-15

    N-methyl-d-aspartate receptors (NMDARs) play a crucial role in spatial memory formation. In neuropharmacological studies their functioning strongly depends on testing conditions and the dosage of NMDAR antagonists. The aim of this study was to assess the immediate effects of NMDAR block by (+)MK-801 or memantine on short-term allothetic memory. Memory was tested in a working memory version of the Morris water maze test. In our version of the test, rats underwent one day of training with 8 trials, and then three experimental days when rats were injected intraperitoneally with low- 5 (MeL), high - 20 (MeH) mg/kg memantine, 0.1mg/kg MK-801 or 1ml/kg saline (SAL) 30min before testing, for three consecutive days. On each experimental day there was just one acquisition and one test trial, with an inter-trial interval of 5 or 15min. During training the hidden platform was relocated after each trial and during the experiment after each day. The follow-up effect was assessed on day 9. Intact rats improved their spatial memory across the one training day. With a 5min interval MeH rats had longer latency then all rats during retrieval. With a 15min interval the MeH rats presented worse working memory measured as retrieval minus acquisition trial for path than SAL and MeL and for latency than MeL rats. MK-801 rats had longer latency than SAL during retrieval. Thus, the high dose of memantine, contrary to low dose of MK-801 disrupts short-term memory independent on the time interval between acquisition and retrieval. This shows that short-term memory tested in a working memory version of water maze is sensitive to several parameters: i.e., NMDA receptor antagonist type, dosage and the time interval between learning and testing. Copyright © 2016. Published by Elsevier B.V.

  16. Testing Affine Term Structure Models in Case of Transaction Costs

    NARCIS (Netherlands)

    Driessen, J.J.A.G.; Melenberg, B.; Nijman, T.E.

    1999-01-01

    In this paper we empirically analyze the impact of transaction costs on the performance of affine interest rate models. We test the implied (no arbitrage) Euler restrictions, and we calculate the specification error bound of Hansen and Jagannathan to measure the extent to which a model is

  17. Long-term effects on biotransformation of labelled choline in different parts of the rat brain induced by single choline injections

    Energy Technology Data Exchange (ETDEWEB)

    Nordberg, A.; Wahlstroem, G.

    1988-01-01

    The long-term effects of single choline (Ch) injections on the uptake and metabolism of a tracer dose of /sup 3/H-Ch were studied in male rats. Choline was administered as a threshold infusion to obtain convulsions 10 and 4 weeks before sacrific (group 1). At a single threshold infusion of choline 4 weeks before sacrifice no convulsions were induced in 50% of the animals in a second group (group 2-) whereas convulsions were induced in the remainder of the animals in this group (group 2+). Group 3 contained control animals. One min. after administration of a tracer dose of /sup 3/H-Ch the animals were sacrificed and examined for /sup 3/H-total activity, /sup 3/H-Ch, /sup 3/H-acetylcholine (/sup 3/H-ACh) and /sup 3/H-phosphorylcholine (/sup 3/-H-PhCh). These activities were determined in three parts of the brain (cortex, striatum, midbrain + medulla oblongata). In the cortex a significant negative correlation between brain weight and /sup 3/H-ACh synthesis was seen in group 1. A comparison between group 2+ and group 2- indicated that induced convulsions were not critical for this effect. In the striatum there was a significant reduction in the total uptake of radioactivity in group 1 and group 2- when values were compared to the control group. Furthermore a significant positive correlation was detected between the concentration of radiolabel and /sup 3/H-ACh synthesis and a negative relationship with the level of /sup 3/H-Ch. In the midbrain preparation the synthesis of /sup 3/H-ACh was reduced in group 1 where a significant negative correlation was found between the average threshold dose of choline and both /sup 3/H-Ach and /sup 3/H-PhCh synthesis. Thus the Ch threshold doses given several weeks before testing seem to have long term effects on the uptake and utilization of a tracer dose of /sup 3/H-Ch in the cortex and striatum.

  18. Safety Design Strategy for the Advanced Test Reactor Emergency Firewater Injection System Replacement Project

    International Nuclear Information System (INIS)

    Duckwitz, Noel

    2011-01-01

    In accordance with the requirements of U.S. Department of Energy (DOE) Order 413.3B, 'Program and Project Management for the Acquisition of Capital Assets,' safety must be integrated into the design process for new or major modifications to DOE Hazard Category 1, 2, and 3 nuclear facilities. The intended purpose of this requirement involves the handling of hazardous materials, both radiological and chemical, in a way that provides adequate protection to the public, workers, and the environment. Requirements provided in DOE Order 413.3B and DOE Order 420.1B, 'Facility Safety,' and the expectations of DOE-STD-1189-2008, 'Integration of Safety into the Design Process,' provide for identification of hazards early in the project and use of an integrated team approach to design safety into the facility. This safety design strategy provides the basic safety-in-design principles and concepts that will be used for the Advanced Test Reactor Reliability Sustainment Project. While this project does not introduce new hazards to the ATR, it has the potential for significant impacts to safety-related systems, structures, and components that are credited in the ATR safety basis and are being replaced. Thus the project has been determined to meet the definition of a major modification and is being managed accordingly.

  19. ISP-50 Specifications for a Direct Vessel Injection Line Break Test with the ATLAS

    International Nuclear Information System (INIS)

    Choi, Ki Yong; Baek, Won Pil; Kim, Yeon Sik; Park, Hyun Sik; Cho, Seok; Kang, Kyoung Ho; Choi, Nam Hyun; Min, Kyoung Ho

    2009-06-01

    An OECD/NEA International Standard Problem Exercise (ISP) focussing on a DVI line break simulation result with the ATLAS was approved by the NEA Committee on the Safety of Nuclear Installation (CSNI) meeting in December 2008 and was numbered by ISP-50. The ISP-50 program will be operated by an operating agency, KAERI for three years starting from the physical year 2009. Fourteen international organizations confirmed their participation in the ISP-50, including NRC (USA), JAEA, JNES (Japan), GRS (Germany), KFKI-AEKI (Hungary), EDO Gidropress (Russia), VTT, Fortum (Finland), NRI (Czech Republic), Univ. of Pisa (Italy), KINS, KNF, KOPEC, and KAERI (Korea). In addition, KTH in Sweden and HSE in UK are considering late participation. Recently, NPIC and CIAE in China hope to join the ISP-50. As for the safety analysis codes, nine codes are expected to be used for the ISP-50: MARS-3D, RELAP5- 3D, RELAP5, TRACE, CATHARE, APROS, ATHELET, TRAP, and KORSAR. It is the first ISP exercise in Korea in which a domestic test facility is utilized by international nuclear society and this exercise will contribute to extending our physical understanding on thermal hydraulic phenomena during the DVI line break accidents and to verifying the best-estimate thermal-hydraulic safety analysis codes. This report was prepared to define technical specifications of the ISP-50 exercise according the guideline provided by OECD/CSNI. It includes general objectives, phases, deliverables to participants, parameters required for comparison and the time table

  20. LOFT/LP-SB-3, Loss of Fluid Test, Cold Leg Break LOCA, No High Pressure injection System (HPIS)

    International Nuclear Information System (INIS)

    1989-01-01

    1 - Description of test facility: The LOFT Integral Test Facility is a scale model of a LPWR. The intent of the facility is to model the nuclear, thermal-hydraulic phenomena which would take place in a LPWR during a LOCA. The general philosophy in scaling coolant volumes and flow areas in LOFT was to use the ratio of the LOFT core [50 MW(t)] to a typical LPWR core [3000 MW(t)]. For some components, this factor is not applied; however, it is used as extensively as practical. In general, components used in LOFT are similar in design to those of a LPWR. Because of scaling and component design, the LOFT LOCA is expected to closely model a LPWR LOCA. 2 - Description of test: The sixth OECD LOFT experiment was conducted on 5 March 1984. It simulated a 1.8-in cold leg break LOCA with no HPIS available. This experiment was designed mainly for investigation of plant recovery effectiveness using secondary bleed and feed during core uncover and addressed accumulator injection at low pressure differentials. 3 - Experimental limitations or shortcomings: Short core and steam generator, excessive core bypass, other scaling compromises, and lack of adequate measurements in certain areas

  1. Steroid injections in the treatment of humeral unicameral bone cysts: long-term follow-up and review of the literature.

    Science.gov (United States)

    Pavone, V; Caff, G; Di Silvestri, C; Avondo, S; Sessa, G

    2014-05-01

    Retrospective evaluation of long-term effectiveness of the steroid injections treatment in patients with unicameral bone cysts (UBC). From January 1993 to April 2005, 23 children affected by proximal humeral UBC were evaluated according to the Neer-Cole classification system and treated with serial methylprednisolone acetate's injections. The patients were followed up at 1, 3, 6 and 12 months and then every year until the adolescence. After treatment, in 15 out of 23 patients (65.2%), the humeral cysts were referred, respectively, as Grade 1 and in four as Grade 2. In 4 patients, a refracture occurred. Statistical analysis showed an overall good response in 82.6% of patients at the end of the follow-up. Minor complication including skin discoloration accounted for 13.04%. The steroid injections showed to be an alternative excellent treatment for UBC, with complete healing of the lesions in the majority of cases. This procedure is not expensive, mini-invasive, with low surgical risk and short hospitalization.

  2. Verification test calculations for the Source Term Code Package

    International Nuclear Information System (INIS)

    Denning, R.S.; Wooton, R.O.; Alexander, C.A.; Curtis, L.A.; Cybulskis, P.; Gieseke, J.A.; Jordan, H.; Lee, K.W.; Nicolosi, S.L.

    1986-07-01

    The purpose of this report is to demonstrate the reasonableness of the Source Term Code Package (STCP) results. Hand calculations have been performed spanning a wide variety of phenomena within the context of a single accident sequence, a loss of all ac power with late containment failure, in the Peach Bottom (BWR) plant, and compared with STCP results. The report identifies some of the limitations of the hand calculation effort. The processes involved in a core meltdown accident are complex and coupled. Hand calculations by their nature must deal with gross simplifications of these processes. Their greatest strength is as an indicator that a computer code contains an error, for example that it doesn't satisfy basic conservation laws, rather than in showing the analysis accurately represents reality. Hand calculations are an important element of verification but they do not satisfy the need for code validation. The code validation program for the STCP is a separate effort. In general the hand calculation results show that models used in the STCP codes (e.g., MARCH, TRAP-MELT, VANESA) obey basic conservation laws and produce reasonable results. The degree of agreement and significance of the comparisons differ among the models evaluated. 20 figs., 26 tabs

  3. The long-term stability of cement - Leaching tests

    International Nuclear Information System (INIS)

    Engkvist, I.; Albinsson, Y.; Johansson Engkvist, W.

    1996-06-01

    The concrete construction in the Swedish repository for long-lived low and intermediate level waste will give a stable chemical near field environment for 10 5 years. The pH is expected to exceed 12 for the life time for most of the radionuclides in the repository in both saline and non-saline groundwaters. This is shown by static leaching experiments performed in saline and non-saline granitic groundwater conditions. Five gram portions of crushed ordinary Portland cement paste were equilibrated with 20 ml of synthetic saline or non-saline groundwater in a nitrogen atmosphere. Each week 12 ml (60%) of the water was replaced. The withdrawn water was used for chemical analyses and the results were used to monitor the degradation of the cement paste. After eighty weeks, some samples were analysed for mineral composition and compared with the original unleached paste. The results indicated no secondary ettringite or calcite formation. The results also supported the conclusion that the salinity of the contacting water is of minor importance for the long-term performance of the cement paste. 18 refs, 32 figs

  4. The University of Minnesota aquifer thermal energy storage (ATES) field test facility -- system description, aquifer characterization, and results of short-term test cycles

    Energy Technology Data Exchange (ETDEWEB)

    Walton, M.; Hoyer, M.C.; Eisenreich, S.J.; Holm, N.L.; Holm, T.R.; Kanivetsky, R.; Jirsa, M.A.; Lee, H.C.; Lauer, J.L.; Miller, R.T.; Norton, J.L.; Runke, H. (Minnesota Geological Survey, St. Paul, MN (United States))

    1991-06-01

    Phase 1 of the Aquifer Thermal Energy Storage (ATES) Project at the University of Minnesota was to test the feasibility, and model, the ATES concept at temperatures above 100{degrees}C using a confined aquifer for the storage and recovery of hot water. Phase 1 included design, construction, and operation of a 5-MW thermal input/output field test facility (FTF) for four short-term ATES cycles (8 days each of heat injection, storage, and heat recover). Phase 1 was conducted from May 1980 to December 1983. This report describes the FTF, the Franconia-Ironton-Galesville (FIG) aquifer used for the test, and the four short-term ATES cycles. Heat recovery; operational experience; and thermal, chemical, hydrologic, and geologic effects are all included. The FTF consists of monitoring wells and the source and storage well doublet completed in the FIG aquifer with heat exchangers and a fixed-bed precipitator between the wells of the doublet. The FIG aquifer is highly layered and a really anisotropic. The upper Franconia and Ironton-Galesville parts of the aquifer, those parts screened, have hydraulic conductivities of {approximately}0.6 and {approximately}1.0 m/d, respectively. Primary ions in the ambient ground water are calcium and magnesium bicarbonate. Ambient temperature FIG ground water is saturated with respect to calcium/magnesium bicarbonate. Heating the ground water caused most of the dissolved calcium to precipitate out as calcium carbonate in the heat exchanger and precipitator. Silica, calcium, and magnesium were significantly higher in recovered water than in injected water, suggesting dissolution of some constituents of the aquifer during the cycles. Further work on the ground water chemistry is required to understand water-rock interactions.

  5. Corrective Action Investigation plan for Corrective Action Unit 546: Injection Well and Surface Releases, Nevada Test Site, Nevada, Revision 0

    International Nuclear Information System (INIS)

    Alfred Wickline

    2008-01-01

    Corrective Action Unit (CAU) 546 is located in Areas 6 and 9 of the Nevada Test Site, which is approximately 65 miles northwest of Las Vegas, Nevada. Corrective Action Unit 546 is comprised of two Corrective Action Sites (CASs) listed below: 06-23-02, U-6a/Russet Testing Area 09-20-01, Injection Well These sites are being investigated because existing information on the nature and extent of potential contamination is insufficient to evaluate and recommend corrective action alternatives. Additional information will be obtained by conducting a corrective action investigation (CAI) before evaluating corrective action alternatives and selecting the appropriate corrective action for each CAS. The results of the field investigation will support a defensible evaluation of viable corrective action alternatives that will be presented in the Corrective Action Decision Document. The sites will be investigated based on the data quality objectives (DQOs) developed on November 8, 2007, by representatives of the Nevada Division of Environmental Protection and U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Site Office. The DQO process has been used to identify and define the type, amount, and quality of data needed to develop and evaluate appropriate corrective actions for CAU 546

  6. UPTF-TRAM test A3. Turn-over of the hot-leg injected ECC in the steam generator direction

    International Nuclear Information System (INIS)

    Tenckhoff; Brand, B.; Weiss, P.

    1993-06-01

    The UPTF TRAM test A3 was a separate effects test to investigate the interaction between the hot leg-injected ECC and the single-phase or two-phase natural circulation in the hot leg in the case of an SBLOCA in a PWR. The experimental investigation of 7 runs was mainly concentrated on the following phenomena: - Transport of hot leg injected ECC water to the upper plenum or in the direction of steam generator, depending on the loop mass flow, -Utilization of the condensation potential of ECC water, - Mixing of the saturated water with the ECC water, - Effect of hot leg injection on the flow phenomena in the hot leg, - Effect of pressure (3 and 15 bar) on the scaling and hence the verification of the scaling concept applied. A preliminary evaluation of the test is presented in the Quick Look Report. (orig.) [de

  7. Testosterone Injection

    Science.gov (United States)

    ... typical male characteristics. Testosterone injection works by supplying synthetic testosterone to replace the testosterone that is normally ... as a pellet to be injected under the skin.Testosterone injection may control your symptoms but will ...

  8. Challenges in defining a radiologic and hydrologic source term for underground nuclear test centers, Nevada Test Site, Nye County, Nevada

    International Nuclear Information System (INIS)

    Smith, D.K.

    1995-06-01

    The compilation of a radionuclide inventory for long-lived radioactive contaminants residual from nuclear testing provides a partial measure of the radiologic source term at the Nevada Test Site. The radiologic source term also includes potentially mobile short-lived radionuclides excluded from the inventory. The radiologic source term for tritium is known with accuracy and is equivalent to the hydrologic source term within the saturated zone. Definition of the total hydrologic source term for fission and activation products that have high activities for decades following underground testing involves knowledge and assumptions which are presently unavailable. Systematic investigation of the behavior of fission products, activation products and actinides under saturated or Partially saturated conditions is imperative to define a representative total hydrologic source term. This is particularly important given the heterogeneous distribution of radionuclides within testing centers. Data quality objectives which emphasize a combination of measurements and credible estimates of the hydrologic source term are a priority for near-field investigations at the Nevada Test Site

  9. The sensitivity testing of Wilms' tumors to cytostatic agents with an autoradiographic in vitro short-term test

    International Nuclear Information System (INIS)

    Willnow, U.

    1984-01-01

    Sensitivity of 15 Wilms' tumors in children was tested towards cytostatic agents in vitro by means of an autoradiographic short-term test. Sensitivity was measured as the magnitude of the inhibition of 3 H-thymidine or 3 H-uridine incorporation. The test was performed with Adriamycin, Actinomycin D, Daunomycin, Bleomycin, Cyclophosphamide, Ifosfamide, Trenimon, and Arabinosylcytosine. None of the tumors is resistant to all substances, they are responsive against 2 or more drugs. The most effective drugs tested are Adriamycin, Actinomycin D and Cyclophosphamide. The tumors show a marked individual sensitivity pattern. This behavior is explained mainly by the usually high proliferative activity of Wilms' tumors. The possibilities and limits of long-term and short-term methods for sensitivity testing are discussed critically. For the evaluation of the results of in vitro testing and in vivo effectiveness the close correlation should be considered between the type of cytostatic agent and proliferation kinetics of the tumor, cytostatic agent and effect on tumor metabolism as well as the effect of the cytostatics and the nucleic acid precursors used for the short-term test. Despite the methodological limitations preclinical testing should be preferred to unselected chemotherapy. (author)

  10. Collaborative testing for key-term definitions under representative conditions: Efficiency costs and no learning benefits.

    Science.gov (United States)

    Wissman, Kathryn T; Rawson, Katherine A

    2018-01-01

    Students are expected to learn key-term definitions across many different grade levels and academic disciplines. Thus, investigating ways to promote understanding of key-term definitions is of critical importance for applied purposes. A recent survey showed that learners report engaging in collaborative practice testing when learning key-term definitions, with outcomes also shedding light on the way in which learners report engaging in collaborative testing in real-world contexts (Wissman & Rawson, 2016, Memory, 24, 223-239). However, no research has directly explored the effectiveness of engaging in collaborative testing under representative conditions. Accordingly, the current research evaluates the costs (with respect to efficiency) and the benefits (with respect to learning) of collaborative testing for key-term definitions under representative conditions. In three experiments (ns = 94, 74, 95), learners individually studied key-term definitions and then completed retrieval practice, which occurred either individually or collaboratively (in dyads). Two days later, all learners completed a final individual test. Results from Experiments 1-2 showed a cost (with respect to efficiency) and no benefit (with respect to learning) of engaging in collaborative testing for key-term definitions. Experiment 3 evaluated a theoretical explanation for why collaborative benefits do not emerge under representative conditions. Collectively, outcomes indicate that collaborative testing versus individual testing is less effective and less efficient when learning key-term definitions under representative conditions.

  11. Single-dose Intramuscular-injection Toxicology Test of Water-soluble Carthami-flos and Cervi cornu parvum Pharmacopuncture in a Rat Model

    Directory of Open Access Journals (Sweden)

    Sunju Park

    2015-09-01

    Full Text Available Objectives: The aim of the study is to investigate both the single-dose intramuscular injection toxicity and the approximate lethal dose of water-soluble Carthami-flos and Cervi cornu parvum pharmacopuncture (WCFC in male and female Sprague-Dawley (SD rats. Methods: The study was conducted at Biotoxtech Co. according to the Good Laboratory Practice (GLP regulation and the toxicity test guidelines of the Ministry of Food and Drug Safety (MFDS after approval of the Institutional Animal Care and Use Committee. Dosages for the control, high dose, middle dose and low dose groups were 0.5 mL/animal of saline and 0.5, 0.25 and 0.125 mL/animal of WCFC, respectively. WCFC was injected into the muscle of the left femoral region by using a disposable syringe (1 mL, 26 gauge. The general symptoms and mortality were observed 30 minutes, 1, 2, 4, and 6 hours after the first injection and then daily for 14 days after the injection. The body weights of the SD rats were measured on the day of the injection (before injection and on the third, seventh, and fourteenth days after the injection. Serum biochemical and hematologic tests, necropsy examinations, and histopathologic examinations at the injection site were performed after the observation period. Results: No deaths, abnormal clinical symptoms, or significant weight changes were observed in either male or female SD rats in the control or the test (0.125, 0.25, and 0.5 mL/animal groups during the observation period. No significant differences in hematology and serum biochemistry and no macroscopic abnormalities at necropsy were found. No abnormal reactions at injection sites were noted on the topical tolerance tests. Conclusion: The results of this single-dose toxicity study show that WCFC is safe, its lethal doses in male and female SD rats being estimated to be higher than 0.5 mL/animal.

  12. Effects of Repeated Testing on Short- and Long-Term Memory Performance across Different Test Formats

    Science.gov (United States)

    Stenlund, Tova; Sundström, Anna; Jonsson, Bert

    2016-01-01

    This study examined whether practice testing with short-answer (SA) items benefits learning over time compared to practice testing with multiple-choice (MC) items, and rereading the material. More specifically, the aim was to test the hypotheses of "retrieval effort" and "transfer appropriate processing" by comparing retention…

  13. Study on the correlation between long-term exposure tests and accelerated corrosion tests by the combined damage of salts

    International Nuclear Information System (INIS)

    Park, Sang Soon; Lee, Min Woo

    2014-01-01

    Interest in the durability assessment and structural performance has increased according to an increase of concrete structures in salt damage environment recent years. Reliable way ensuring the most accelerated corrosion test is a method of performing the rebar corrosion monitoring as exposed directly to the marine test site exposure. However, long-term exposure test has a disadvantage because of a long period of time. Therefore, many studies on reinforced concrete in salt damage environments have been developed as alternatives to replace this. However, accelerated corrosion test is appropriate to evaluate the critical chlorine concentration in the short term, but only accelerated test method, is not easy to get correct answer. Accuracy of correlation acceleration test depends on the period of the degree of exposure environments. Therefore, in this study, depending on the concrete mix material, by the test was performed on the basis of the composite degradation of the salt damage, and investigate the difference of corrosion initiation time of the rebar, and indoor corrosion time of the structure, of the marine environment of the actual environments were investigated. The correlation coefficient was derived in the experiment. Long-term exposure test was actually conducted in consideration of the exposure conditions submerged zone, splash zone and tidal zone. The accelerated corrosion tests were carried out by immersion conditions, and by the combined deterioration due to the carbonation and accelerated corrosion due to wet and dry condition

  14. Equipment for long-term testing of material creep in liquid sodium

    International Nuclear Information System (INIS)

    Dufek, F.; Walder, V.; Cech, V.; Winkler, P.

    1980-01-01

    A sodium test plant is described and the methods are shown of securing the desired test specifications. The facility is used for the long-term testing of nonsteady material creep under the action of temperature and mechanical stress due to the static or pulsed overpressure of inert gas inside a tube specimen and a simultaneous effect of sodium flow on the outside wall. The test results are to be used for comparing Czechoslovak-made steels with foreign materials and also for testing the degradation effects of the above phenomena on the standardized long-term properties in inert and steady state conditions. (B.S.)

  15. Preimplantation genetic screening as an alternative to prenatal testing for Down syndrome : preferences of women undergoing in vitro fertilization/intracytoplasmic sperm injection treatment

    NARCIS (Netherlands)

    Twisk, Moniek; Haadsma, Maaike L.; van der Veen, Fulco; Repping, Sjoerd; Mastenbroek, Sebastiaan; Heineman, Maas-Jan; Bossuyt, Patrick M. M.; Korevaar, Johanna C.

    2007-01-01

    Objective: Although the primary goal of preimplantation genetic screening (PGS) is to increase pregnancy rates in women undergoing IVF/intracytoplasmic sperm injection treatment, it has been suggested that it may also be used as an alternative to prenatal testing for Down syndrome. Design: Trade-off

  16. Preimplantation genetic screening as an alternative to prenatal testing for Down syndrome: preferences of women undergoing in vitro fertilization/intracytoplasmic sperm injection treatment

    NARCIS (Netherlands)

    Twisk, Moniek; Haadsma, Maaike L.; van der Veen, Fulco; Repping, Sjoerd; Mastenbroek, Sebastiaan; Heineman, Maas-Jan; Bossuyt, Patrick M. M.; Korevaar, Johanna C.

    2007-01-01

    Objective: Although the primary goal of preimplantation genetic screening (PGS) is to increase pregnancy rates in women undergoing IVF/intracytoplasmic sperm injection treatment, it has been suggested that it may also be used as an alternative to prenatal testing for Down syndrome. Design: Trade-off

  17. Long-term tissue distribution and steady state activity ratios of 232Th and its daughters in rats after intravascular injection of thorotrast

    International Nuclear Information System (INIS)

    Norimura, Toshiyuki; Tsuchiya, Takehiko; Hatakeyama, Satoru; Yamamoto, Hisao; Okajima, Shunzo.

    1989-01-01

    To estimate the absorbed dose in the critical organs of Thorotrast patients, it is necessary to know not only the distribution and concentration of 232 Th but also its daughter nuclides in the body. The present investigation was undertaken in order to clarify the long-term 232 Th tissue distribution and steady state activity ratios between subsequent daughters in the critical tissues, using about 30 Wister male rats, as a basis for estimating absorbed doses. The tissue distribution of thorium was examined by means of an autoradiographty of the whole body and/or the gamma-ray spectrometry at various times during 2 to 24 months following injection. The concentrations of daughter nuclides in tissues were determined by repetitive gamma examination over a period from 1 hr to 35 days after being sacrificed. The data indicate (1) that approximately 90% of injected Thorotrast is retained in the body for a prolonged period, but about 50% of radium and 10% of radon produced from thorium are eliminated from the body, (2) that the mean steady state activity ratios of 224 Ra and 212 Pb to 228 Th for liver are 0.56 and 0.28, and 0.54 and 0.16 for spleen, 0.58 and 0.82 for lungs, respectively, and (3) that the parent 228 Th is translocated to the bone. (author)

  18. A 125I-radiolabelled probe for vinblastine and vindesine radioimmunoassays: applications to measurements of vindesine plasma levels in man after intravenous injections and long-term infusions

    International Nuclear Information System (INIS)

    Rahmani, R.; Barbet, J.; Cano, J.-P.

    1983-01-01

    The transformation of vinblastine into a reactive acid azide was used for the preparation of a vindesine-glycyl-tyrosine conjugate. This conjugate was radiolabelled [ 125 I] and used as a tracer for the radioimmunoassay of vinblastine and vindesine with antisera developed by the Eli Lilly Research Laboratories and by the authors. Its higher specific activity as compared to tritiated vinblastine significantly increases the sensitivity of the assay (0.05 μg/l as compared to 0.6 μg/l). It was then possible to monitor vindesine plasma levels for more than 60 h after intravenous bolus injection and to evaluate the elimination rates more accurately. When plasma levels were also measurable using tritiated vinblastine a satisfactory agreement was observed with determinations performed with radioiodinated vindesine-glycyl-tyrosine. Furthermore, the use of a #betta#-emitting probe simplifies the radioimmunoassay procedure and accordingly increases its reproducibility. A few examples of vindesine level measurements in human plasma collected after bolus intravenous injection and during long-term infusion are given. (Auth.)

  19. Amsterdam Short-Term Memory test: a new procedure for the detection of feigned memory deficits

    NARCIS (Netherlands)

    Schagen, S.; Schmand, B.; de Sterke, S.; Lindeboom, J.

    1997-01-01

    The validity of two malingering tests, the newly developed Amsterdam Short-Term Memory (ASTM) test and the Distraction test (Baker, Hanley, Jackson, Kimmance, & Slade, 1993) was examined in a group of patients with closed-head injury (CHI), a normal control group, and a control group with

  20. Why wait if you can switch? A short term testing effect in cross-language recognition.

    NARCIS (Netherlands)

    Verkoeijen, Peter; Bouwmeester, Samantha; Camp, Gino

    2018-01-01

    Taking a memory test after an initial study phase produces better long-term retention than restudying the items, a phenomenon known as the testing effect. We propose that this effect emerges because testing strengthens semantic features of items’ memory traces, whereas restudying strengthens surface

  1. Effects of Two Short-Term Desensitization Methods in the Treatment of Test Anxiety

    Science.gov (United States)

    Richardson, Frank C.; Suinn, Richard M.

    1974-01-01

    Accelerated massed desensitization and anxiety management training were compared with standard systematic desensitization in terms of reducing self-reported test anxiety in high test-anxious college students. All three treatments significantly reduced test anxiety as compared with a waiting list control group. (Author)

  2. Long-Term Capital Goods Importation and Minimum Wage Relationship in Turkey: Bounds Testing Approach

    Directory of Open Access Journals (Sweden)

    Tastan Serkan

    2015-04-01

    Full Text Available In order to examine the long-term relationship between capital goods importation and minimum wage, autoregressive distributed lag (ARDL bounds testing approach to the cointegration is used in the study. According to bounds test results, a cointegration relation exists between the capital goods importation and the minimum wage. Therefore an ARDL(4,0 model is estimated in order to determine the long and short term relations between variables. According to the empirical analysis, there is a positive and significant relationship between the capital goods importation and the minimum wage in Turkey in the long term. A 1% increase in the minimum wage leads to a 0.8% increase in the capital goods importation in the long term. The result is similar for short term coefficients. The relationship observed in the long term is preserved in short term, though in a lower level. In terms of error correction model, it can be concluded that error correction mechanism works as the error correction term is negative and significant. Short term deviations might be resolved with the error correction mechanism in the long term. Accordingly, approximately 75% of any deviation from equilibrium which might arise in the previous six month period will be resolved in the current six month period. This means that returning to long term equilibrium progresses rapidly.

  3. CT-guided cervical nerve root injections: comparing the immediate post-injection anesthetic-related effects of the transforaminal injection with a new indirect technique

    International Nuclear Information System (INIS)

    Sutter, Reto; Pfirrmann, Christian W.A.; Peterson, Cynthia K.; Zanetti, Marco; Hodler, Juerg

    2011-01-01

    To describe an ''indirect'' cervical nerve root injection technique with a dorsal approach that should carry less inherent risk than the ''direct'' cervical transforaminal injection approach, and to compare the immediate post-injection results of the two procedures. The indirect and direct cervical nerve root injection procedures are described in detail. Fifty-three consecutive patients receiving the indirect nerve root injections during 2009-2010 were age- and gender-matched to 53 patients who underwent direct transforaminal nerve root injections performed in 2006. Pain level data were collected immediately before and 20-30 min after each procedure. The percentages of pain change in the two groups were compared using the unpaired Student's t test. Fifty-two men (mean age 49) and 54 women (mean age 55) were included. The mean percentage of pain reduction for patients receiving indirect nerve root injections was 38.4% and for those undergoing the direct nerve root injections approach it was 43.2%. This was not significantly different (P = 0.455). No immediate or late adverse effects were reported after either injection procedure. The indirect cervical nerve root injection procedure is a potentially safer alternative to direct cervical transforaminal nerve root injections. The short-term pain reduction is similar using the two injection methods. (orig.)

  4. Long-Term Outcomes in Patients with Neovascular Age-Related Macular Degeneration Who Maintain Dry Macula after Three Monthly Ranibizumab Injections.

    Science.gov (United States)

    Kim, Kyung Min; Kim, Jae Hui; Chang, Young Suk; Kim, Jong Woo; Kim, Chul Gu

    2018-01-01

    To evaluate long-term changes in visual acuity and retinal microstructure in patients with neovascular age-related macular degeneration (AMD) who had maintained dry macula after initial treatment. This retrospective observational study included 55 eyes that were diagnosed with neovascular AMD, were treated with three monthly ranibizumab injections, and maintained dry macula during a two-year follow-up. Best-corrected visual acuity (BCVA) at three months and at the final follow-up were compared, and the degree of visual improvement was compared between eyes with and without improvement of the ellipsoid zone. In addition, the incidence of improvement of the ellipsoid zone was compared between eyes with different extents of disruption. The mean follow-up period was 30.3 ± 4.1 months. BCVA at three months and at the final follow-up was 0.51 ± 0.46 and 0.45 ± 0.49 (P200 μm of disruption of the ellipsoid zone, 15 (42.9%) showed improvement of the ellipsoid zone, and the improvement in BCVA was greater in these eyes than that in the remaining 20 eyes (P=0.021). A higher incidence of improvement of the ellipsoid zone was noted in eyes with 200 to 800 μm of disruption than in eyes with >800 μm of disruption (P<0.001). Long-term improvement in visual acuity was noted in eyes that had maintained dry macula after three ranibizumab injections. The status of the ellipsoid zone at three months was closely associated with visual improvement.

  5. Long-term clinical benefit and cost-effectiveness of an 8-week multimodal knee osteoarthritis management program incorporating intra-articular sodium hyaluronate (Hyalgan® injections

    Directory of Open Access Journals (Sweden)

    Miller LE

    2017-05-01

    Full Text Available Larry E Miller,1 Michael J Sloniewsky,2 Thomas E Gibbons,3 Janice G Johnston,4 Kent D Vosler,4 Saad Nasir5 1Miller Scientific Consulting, Inc., Asheville, NC, 2RMG Holding, Inc., Florence, 3Doctors Care, PA, Columbia, SC, 4Arrowhead Health Centers, Glendale, AZ, 5Fidia Pharma USA Inc., Parsippany, NJ, USA Background: Given the poor long-term effectiveness of focused nonsurgical knee osteoarthritis (OA treatments, alternative therapies are needed for patients who have unsuccessfully exhausted nonsurgical options.Methods: A telephone interview was conducted in patients who participated in a single 8-week multimodal knee OA treatment program (mean follow-up: 3.7 years, range: 2.7–4.9 years. The program consisted of five intra-articular knee injections of sodium hyaluronate (Hyalgan®, with each injection given 1 week apart, structured physical therapy, knee bracing, and patient education. Clinical outcomes included knee pain severity, Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC subscores, current medication use, and history of total knee arthroplasty. Base-case, subgroup, and sensitivity analyses were conducted to determine the incremental cost-effectiveness ratio (ICER of the treatment program with comparisons made to historical literature controls undergoing usual care. Results: A total of 218 patients (54% provided long-term follow-up data. Knee pain severity decreased 60% and WOMAC subscores decreased 33%–42% compared to baseline (all p<0.001. Total knee arthroplasty was performed in 22.8% (81/356 of knees during follow-up. The treatment program was highly cost-effective compared to usual care with a base-case ICER of $6,000 per quality-adjusted life year (QALY. Results of subgroup analyses, one-way deterministic sensitivity analyses, and second-order probabilistic sensitivity analyses resulted in ICERs ranging from $3,996 to $10,493 per QALY. The percentage of simulations with an ICER below willingness

  6. Assessment of the Efficiency of Consolidation Treatment through Injections of Expanding Resins by Geotechnical Tests and 3D Electrical Resistivity Tomography

    Science.gov (United States)

    2015-01-01

    The design and execution of consolidation treatment of settled foundations by means of injection of polyurethane expanding resins require a proper investigation of the state of the foundation soil, in order to better identify anomalies responsible for the instability. To monitor the injection process, a procedure has been developed, which involves, in combination with traditional geotechnical tests, the application of a noninvasive, geophysical technique based on the electrical resistivity, which is strongly sensitive to presence of water or voids. Three-dimensional electrical resistivity tomography is a useful tool to produce effective 3D images of the foundation soils before, during, and after the injections. The achieved information allows designing the consolidation scheme and monitoring its effects on the treated volumes in real time. To better understand the complex processes induced by the treatment and to learn how variations of resistivity accompany increase of stiffness, an experiment was carried out in a full-scale test site. Injections of polyurethane expanding resin were performed as in real worksite conditions. Results confirm that the experimented approach by means of 3D resistivity imaging allows a reliable procedure of consolidation, and geotechnical tests demonstrate the increase of mechanical stiffness. PMID:26167521

  7. An experimental study on the thermal-hydraulic phenomena in the Hybrid Safety Injection Tank using a separate effect test facility

    International Nuclear Information System (INIS)

    Ryu, Sung Uk; Ryu, Hyobong; Park, Hyun-Sik; Yi, Sung-Jae

    2016-01-01

    Highlights: • The experimental study on the pressure balancing between the Hybrid SIT and PZR. • The effects of different variables affecting the pressure balancing are investigated. • A sensitivity analysis on the pressure variations of the Hybrid SIT. - Abstract: This paper reports an experimental research for investigating thermal hydraulic phenomena of Hybrid Safety Injection Tank (Hybrid SIT) using a separate effect test facility in Korea Atomic Energy Research Institute (KAERI). The Hybrid SIT is a passive safety injection system that enables the safety injection water to be injected into the reactor pressure vessel throughout all operating pressures by connecting the top of the SIT and the pressurizer (PZR). The separate effect test (SET) facility of Hybrid SIT, which is designed based on the APR+ power plant, comprises a PZR, Hybrid SIT, pressure balancing line (PBL), injection line (IL), nitrogen gas line, and refueling water tank (RWT). Furthermore, the pressure loss range of the SET facility was analyzed and compared with that of the reference nuclear power plant. In this research, a condition for balancing the pressure between the Hybrid SIT and PZR is examined and the effects of different variables affecting the pressure balancing, which are flow rate, injection velocity of steam and initial water level, are also investigated. The condition for balancing the pressure between the Hybrid SIT and PZR was derived theoretically from a pressure network for the Hybrid SIT, pressurizer, and reactor pressure vessel. Additionally, a sensitivity analysis as a theoretical approach was conducted on the pressure variations in relation to the rate of steam condensation inside the Hybrid SIT. The results showed that pressure of the Hybrid SIT was predominantly determined by the rate of steam condensation. The results showed that if the rate of condensation increased or decreased by 10%, the Hybrid SIT pressure at the pressure balancing point decreased or

  8. Providing Extrinsic Reward for Test Performance Undermines Long-Term Memory Acquisition

    Directory of Open Access Journals (Sweden)

    Christof eKuhbandner

    2016-02-01

    Full Text Available Based on numerous studies showing that testing studied material can improve long-term retention more than restudying the same material, it is often suggested that the number of tests in education should be increased to enhance knowledge acquisition. However, testing in real-life educational settings often entails a high degree of extrinsic motivation of learners due to the common practice of placing important consequences on the outcome of a test. Such an effect on the motivation of learners may undermine the beneficial effects of testing on long-term memory because it has been shown that extrinsic motivation can reduce the quality of learning. To examine this issue, participants learned foreign language vocabulary words, followed by an immediate test in which one third of the words were tested and one third restudied. To manipulate extrinsic motivation during immediate testing, participants received either monetary reward contingent on test performance or no reward. After one week, memory for all words was tested. In the immediate test, reward reduced correct recall and increased commission errors, indicating that reward reduced the number of items that can benefit from successful retrieval. The results in the delayed test revealed that reward additionally reduced the gain received from successful retrieval because memory for initially successfully retrieved words was lower in the reward condition. However, testing was still more effective than restudying under reward conditions because reward undermined long-term memory for concurrently restudied material as well. These findings indicate that providing performance-contingent reward in a test can undermine long-term knowledge acquisition.

  9. Providing Extrinsic Reward for Test Performance Undermines Long-Term Memory Acquisition.

    Science.gov (United States)

    Kuhbandner, Christof; Aslan, Alp; Emmerdinger, Kathrin; Murayama, Kou

    2016-01-01

    Based on numerous studies showing that testing studied material can improve long-term retention more than restudying the same material, it is often suggested that the number of tests in education should be increased to enhance knowledge acquisition. However, testing in real-life educational settings often entails a high degree of extrinsic motivation of learners due to the common practice of placing important consequences on the outcome of a test. Such an effect on the motivation of learners may undermine the beneficial effects of testing on long-term memory because it has been shown that extrinsic motivation can reduce the quality of learning. To examine this issue, participants learned foreign language vocabulary words, followed by an immediate test in which one-third of the words were tested and one-third restudied. To manipulate extrinsic motivation during immediate testing, participants received either monetary reward contingent on test performance or no reward. After 1 week, memory for all words was tested. In the immediate test, reward reduced correct recall and increased commission errors, indicating that reward reduced the number of items that can benefit from successful retrieval. The results in the delayed test revealed that reward additionally reduced the gain received from successful retrieval because memory for initially successfully retrieved words was lower in the reward condition. However, testing was still more effective than restudying under reward conditions because reward undermined long-term memory for concurrently restudied material as well. These findings indicate that providing performance-contingent reward in a test can undermine long-term knowledge acquisition.

  10. Granisetron Injection

    Science.gov (United States)

    Granisetron immediate-release injection is used to prevent nausea and vomiting caused by cancer chemotherapy and to ... nausea and vomiting that may occur after surgery. Granisetron extended-release (long-acting) injection is used with ...

  11. Edaravone Injection

    Science.gov (United States)

    Edaravone injection is used to treat amyotrophic lateral sclerosis (ALS, Lou Gehrig's disease; a condition in which ... die, causing the muscles to shrink and weaken). Edaravone injection is in a class of medications called ...

  12. Meropenem Injection

    Science.gov (United States)

    ... injection is in a class of medications called antibiotics. It works by killing bacteria that cause infection.Antibiotics such as meropenem injection will not work for colds, flu, or other viral infections. Taking ...

  13. Chloramphenicol Injection

    Science.gov (United States)

    ... injection is in a class of medications called antibiotics. It works by stopping the growth of bacteria..Antibiotics such as chloramphenicol injection will not work for colds, flu, or other viral infections. Taking ...

  14. Colistimethate Injection

    Science.gov (United States)

    ... injection is in a class of medications called antibiotics. It works by killing bacteria.Antibiotics such as colistimethate injection will not work for colds, flu, or other viral infections. Using ...

  15. Defibrotide Injection

    Science.gov (United States)

    Defibrotide injection is used to treat adults and children with hepatic veno-occlusive disease (VOD; blocked blood ... the body and then returned to the body). Defibrotide injection is in a class of medications called ...

  16. Nalbuphine Injection

    Science.gov (United States)

    ... injection is in a class of medications called opioid agonist-antagonists. It works by changing the way ... suddenly stop using nalbuphine injection, you may experience withdrawal symptoms including restlessness; teary eyes; runny nose; yawning; ...

  17. Erythropoietin receptor in human skeletal muscle and the effects of acute and long-term injections with recombinant human erythropoietin on the skeletal muscle

    DEFF Research Database (Denmark)

    Lundby, Carsten; Hellsten, Ylva; Jensen, Mie B. F.

    2008-01-01

    The presence and potential physiological role of the erythropoietin receptor (Epo-R) were examined in human skeletal muscle. In this study we demonstrate that Epo-R is present in the endothelium, smooth muscle cells, and in fractions of the sarcolemma of skeletal muscle fibers. To study...... the potential effects of Epo in human skeletal muscle, two separate studies were conducted: one to study the acute effects of a single Epo injection on skeletal muscle gene expression and plasma hormones and another to study the effects of long-term (14 wk) Epo treatment on skeletal muscle structure. Subjects...... was studied in subjects (n = 8) who received long-term Epo administration, and muscle biopsies were obtained before and after. Epo treatment did not alter mean fiber area (0.84 +/- 0.2 vs. 0.72 +/- 0.3 mm(2)), capillaries per fiber (4.3 +/- 0.5 vs. 4.4 +/- 1.3), or number of proliferating endothelial cells...

  18. Benign tracheobronchial stenoses: changes in short-term and long-term pulmonary function testing after expandable metallic stent placement.

    Science.gov (United States)

    Gotway, Michael B; Golden, Jeffrey A; LaBerge, Jeanne M; Webb, W Richard; Reddy, Gautham P; Wilson, Mark W; Kerlan, Robert K; Gordon, Roy L

    2002-01-01

    To determine the short- and long-term improvement in airflow dynamics in patients undergoing tracheobronchial stent placement for benign airway stenoses. Twenty-two patients underwent 34 tracheal and/or bronchial stent placement procedures for benign airway stenoses and had the results of pulmonary function tests available. Stent placement indications included bronchomalacia after lung transplantation (n = 11), postintubation stenoses (n = 6), relapsing polychondritis (n = 2), and 1 each of tracheomalacia, tracheal compression, and histoplasmosis. Six patients underwent more than one stent placement procedure (range: 2-7 procedures). The mean forced expiratory volume in one second (FEV(1) ), forced expiratory flow rate in the midportion of the forced vital capacity curve (FEF(25-75) ), forced vital capacity, and peak flow (PF) rate obtained before stent placement were compared with those immediately after stent placement and with those measurements most remote from stent placement using the paired two-tailed test. All patients reported improved respiratory function immediately after stent placement. The mean FEV(1), FEF(25-75), and PF rate improved significantly (p stent placement. On long-term follow-up averaging 15 months after stent placement, these parameters declined despite patients' subjective sense of improvement. Segregating the population into transplant and nontransplant airway stenosis etiologies, however, FEF(25-75) and PF rate remained significantly improved (p = 0.045, p = 0.027, respectively), over the long term for the latter. FEV increased after subsequent stent placements for patients receiving multiple stents. Stent placement for benign tracheobronchial stenoses provides significant immediate improvement in airflow dynamics. Long-term improvement in airflow obstruction may be expected, and additional stent placements may further improve pulmonary function.

  19. Kepler Planet Detection Metrics: Pixel-Level Transit Injection Tests of Pipeline Detection Efficiency for Data Release 25

    Science.gov (United States)

    Christiansen, Jessie L.

    2017-01-01

    This document describes the results of the fourth pixel-level transit injection experiment, which was designed to measure the detection efficiency of both the Kepler pipeline (Jenkins 2002, 2010; Jenkins et al. 2017) and the Robovetter (Coughlin 2017). Previous transit injection experiments are described in Christiansen et al. (2013, 2015a,b, 2016).In order to calculate planet occurrence rates using a given Kepler planet catalogue, produced with a given version of the Kepler pipeline, we need to know the detection efficiency of that pipeline. This can be empirically determined by injecting a suite of simulated transit signals into the Kepler data, processing the data through the pipeline, and examining the distribution of successfully recovered transits. This document describes the results for the pixel-level transit injection experiment performed to accompany the final Q1-Q17 Data Release 25 (DR25) catalogue (Thompson et al. 2017)of the Kepler Objects of Interest. The catalogue was generated using the SOC pipeline version 9.3 and the DR25 Robovetter acting on the uniformly processed Q1-Q17 DR25 light curves (Thompson et al. 2016a) and assuming the Q1-Q17 DR25 Kepler stellar properties (Mathur et al. 2017).

  20. Single well field injection test of humate to enhance attenuation of uranium and other radionuclides in an acidic plume

    Energy Technology Data Exchange (ETDEWEB)

    Denham, M. [Savannah River Site (SRS), Aiken, SC (United States)

    2014-09-30

    This report documents the impact of the injected humate on targeted contaminants over a period of 4 months and suggests it is a viable attenuation-based remedy for uranium, potentially for I-129, but not for Sr-90. Future activities will focus on issues pertinent to scaling the technology to full deployment.

  1. Microstructure and elemental distribution of americium containing MOX fuel under the short term irradiation tests

    International Nuclear Information System (INIS)

    Tanaka, Kosuke; Hirosawa, Takashi; Obayashi, Hiroshi; Koyama, Shin Ichi; Yoshimochi, Hiroshi; Tanaka, Kenya

    2008-01-01

    In order to investigate the effect of americium addition to MOX fuels on the irradiation behavior, the 'Am-1' program is being conducted in JAEA. The Am-1 program consists of two short term irradiation tests of 10-minute and 24 hour irradiations and a steady-state irradiation test. The short-term irradiation tests were successfully completed and the post irradiation examinations (PIEs) are in progress. The PIEs for Am-containing MOX fuels focused on the microstructural evolution and redistribution behavior of Am at the initial stage of irradiation and the results to date are reported

  2. Assessment of MARS for downcomer multi-dimensional thermal hydraulics during LBLOCA reflood using KAERI air-water direct vessel injection tests

    Energy Technology Data Exchange (ETDEWEB)

    Won-Jae, Lee; Kwi-Seok, Ha; Chul-Hwa, Song [Korea Atomic Energy Research Inst., Daejeon (Korea, Republic of)

    2001-07-01

    The MARS code has been assessed for the downcomer multi-dimensional thermal hydraulics during a large break loss-of-coolant accident (LBLOCA) reflood of Korean Next Generation Reactor (KNGR) that adopted an upper direct vessel injection (DVI) design. Direct DVI bypass and downcomer level sweep-out tests carried out at 1/50-scale air-water DVI test facility are simulated to examine the capability of MARS. Test conditions are selected such that they represent typical reflood conditions of KNGR, that is, DVI injection velocities of 1.0 {approx} 1.6 m/sec and air injection velocities of 18.0 {approx} 35.0 m/sec, for single and double DVI configurations. MARS calculation is first adjusted to the experimental DVI film distribution that largely affects air-water interaction in a scaled-down downcomer, then, the code is assessed for the selected test matrix. With some improvements of MARS thermal-hydraulic (T/H) models, it has been demonstrated that the MARS code is capable of simulating the direct DVI bypass and downcomer level sweep-out as well as the multi-dimensional thermal hydraulics in downcomer, where condensation effect is excluded. (authors)

  3. Small-Scale Testing Rig for Long-Term Cyclically Loaded Monopiles in Cohesionless Soil

    DEFF Research Database (Denmark)

    Roesen, Hanne Ravn; Ibsen, Lars Bo; Andersen, Lars Vabbersgaard

    2012-01-01

    , and the period of the cyclic loading. However, the design guidance on these issues is limited. Thus, in order to investigate the pile behaviour for cyclically long-term loaded monopiles, a test setup for small-scale tests in saturated dense cohesionless soil is constructed and presented in here. The cyclic...... loading is applied mechanically by means of a testing rig, where the important input parameters: mean level, amplitude, number of cycles, and period of the loading can be varied. The results from a monotonic and a cyclic loading test on an open-ended aluminium pile with diameter = 100 mm and embedded...... length = 600 mm proves that the test setup is capable of applying the cyclic long-term loading. The plastic deformations during loading depend not only on the loading applied but also of the relative density of the soil and, thus, the tests are carried out with relative densities of 77-88%, i.e. similar...

  4. Comparative assessment of therapeutic response to physiotherapy with or without botulinum toxin injection using diffusion tensor tractography and clinical scores in term diplegic cerebral palsy children.

    Science.gov (United States)

    Chaturvedi, Saurabh K; Rai, Yogita; Chourasia, Ankita; Goel, Puneet; Paliwal, Vimal K; Garg, Ravindra K; Rathore, Ram Kishore S; Pandey, Chandra M; Gupta, Rakesh K

    2013-08-01

    The present study was to compare the effects of combined therapy [botulinum (BTX) plus physiotherapy] with physiotherapy alone using diffusion tensor imaging (DTI) derived fractional anisotropy (FA) values of motor and sensory fiber bundles and clinical grade of the disability to see the value of BTX in term children with spastic diplegic cerebral palsy (CP). Clinically diagnosed 36 children participated in the study. All these children were born at term, and had no history of seizures. The study was randomly categorized into two groups: group I (n=18) - physiotherapy alone and group II (n=18) - physiotherapy plus BTX injection. Quantitative diffusion tensor tractography on all these children was performed on motor and sensory fiber bundles on baseline as well as after 6months of therapy. Motor function and clinical grades were also measured by gross motor function measures (GMFM) scale on both occasions. We observed significant change in FA value in motor and sensory fiber bundle as well as in GMFM scores at 6months compared to baseline study in both the groups. However, delta change and relative delta change in FA values of sensory and motor fiber bundle as well as GMFM score between group I and group II was statistically insignificant. We conclude that addition of BTX to physiotherapy regimen does not influence the outcome at 6months with similar insult in children with term diplegic spastic CP. This information may influence management of diplegic CP especially in developing countries, where BTX is beyond the reach of these children. Copyright © 2012 The Japanese Society of Child Neurology. Published by Elsevier B.V. All rights reserved.

  5. Effect of the male factor on the clinical outcome of intracytoplasmic sperm injection combined with preimplantation aneuploidy testing: observational longitudinal cohort study of 1,219 consecutive cycles.

    Science.gov (United States)

    Mazzilli, Rossella; Cimadomo, Danilo; Vaiarelli, Alberto; Capalbo, Antonio; Dovere, Lisa; Alviggi, Erminia; Dusi, Ludovica; Foresta, Carlo; Lombardo, Francesco; Lenzi, Andrea; Tournaye, Herman; Alviggi, Carlo; Rienzi, Laura; Ubaldi, Filippo Maria

    2017-12-01

    To evaluate the impact of the male factor on the outcomes of intracytoplasmic sperm injection (ICSI) cycles combined with preimplantation genetic testing for aneuploidies (PGT-A). Observational longitudinal cohort study. Private in vitro fertilization (IVF) center. A total of 1,219 oocyte retrievals divided into five study groups according to sperm parameters: normozoospermia (N), moderate male factor (MMF), severe oligoasthenoteratozoospermia (OAT-S), obstructive azoospermia (OA), and nonobstructive azoospermia (NOA). ICSI with ejaculated/surgically retrieved sperm, blastocyst culture, trophectoderm-based quantitative polymerase chain reaction PGT-A, and frozen-warmed euploid embryo transfer (ET). The primary outcome measures were fertilization, blastocyst development, and euploidy rates; the secondary outcome measures were live birth and miscarriage rates. Perinatal and obstetrical outcomes were monitored as well. A total of 9,042 metaphase II oocytes were inseminated. The fertilization rate was significantly reduced in MMF, OAT-S, OA, and NOA compared with N (74.8%, 68.7%, 67.3%, and 53.1% vs. 77.2%). The blastocyst rate per fertilized oocyte was significantly reduced in MMF and NOA compared with N (48.6% and 40.6% vs. 49.3%). The timing of blastocyst development also was affected in OA and NOA. Logistic regression analysis adjusted for confounders highlighted NOA as a negative predictor of obtaining an euploid blastocyst per OPU (odds ratio 0.5). When the analysis was performed per obtained blastocyst, however, no correlation between male factor and euploidy rate was observed. Embryo transfers also resulted in similar live birth and miscarriage rates. No impact of sperm factor on obstetrical/perinatal outcomes was observed. Severe male factor impairs early embryonic competence in terms of fertilization rate and developmental potential. However, the euploidy rate and implantation potential of the obtained blastocysts are independent from sperm quality

  6. An investigation of the genetic toxicology of irradiated foodstuffs using short-term test systems

    International Nuclear Information System (INIS)

    Phillips, B.J.; Kranz, E.; Elias, P.S.

    1980-01-01

    As part of a programme of short-term tests used to detect possible genetic toxicity in irradiated foodstuffs, cultured Chinese hamster ovary cells were exposed to extracts and digests of irradiated and unirradiated dates, fish and chicken and subjected to tests for cytotoxicity, sister chromatid exchange induction and mutation to thioguanine resistance. The results showed no evidence of genetic toxicity induced in food by irradiation. The general applicability of cell culture tests to the detection of mutagens in food is discussed. (author)

  7. Short-term effect of ultrasound-guided low-molecular-weight hyaluronic acid injection on clinical outcomes and imaging changes in patients with rheumatoid arthritis of the ankle and foot joints. A randomized controlled pilot trial.

    Science.gov (United States)

    Wang, Chien-Chih; Lee, Si-Huei; Lin, Hsiao-Yi; Liu, Fu-Wei; Chiou, Hong-Jen; Chan, Rai-Chi; Chou, Chen-Liang

    2017-11-01

    To determine whether hyaluronic acid (HA) injection into rheumatoid arthritis ankles and feet can achieve improvement in foot function and reduce synovial hyper-vascularization. Forty-four patients with RA having unilateral or bilateral painful ankle and foot involvement (N = 75) were studied. All the patients were randomized to receive HA (N = 40) or lidocaine (LI) (N = 35) injection at 2-week intervals; Clinical assessments were performed using a visual analog scale (VAS) and foot function index (FFI total ) including subscales of pain (FFI pain) before injection at baseline, 4 weeks (first evaluation) and 12 weeks (secondary evaluation). Imaging evaluation based on color Doppler ultrasound (CDUS) and synovitis scores was performed simultaneously. HA injection improved the VAS score (p = .009), FFI pain (p = .041), and FFI total (p = .032) considerably more than LI injections did at the first evaluation. The CDUS values at first evaluation (p = .005) and secondary evaluation (p injections reduced the CDUS values of more than half of the joints (54%, p = .042) while the control group exhibited no change (20%, p = .56). However, HA injection did not reduce the CDUS values more than LI injection did. Regarding the evaluation of synovial hypertrophy, no significant difference was observed between or within the groups in the synovitis scores. HA injection improved short-term foot function and pain reduction. HA injection may have a modest effect in reducing synovial hyper-vascularization. Further large-scale study is warranted to confirm this result.

  8. Anesthetic efficacy of a repeated intraosseous injection following a primary intraosseous injection.

    Science.gov (United States)

    Jensen, Joanne; Nusstein, John; Drum, Melissa; Reader, Al; Beck, Mike

    2008-02-01

    The purpose of this prospective, randomized, single-blinded study was to determine the anesthetic efficacy of a repeated intraosseous injection given 30 minutes after a primary intraosseous injection. Using a crossover design, 55 subjects randomly received a primary X-tip intraosseous injection (Dentsply Inc, York, PA) of 1.4 mL of 2% lidocaine with epinephrine (using the Wand; Milestone Scientific, Deerfield, IL) and a repeated intraosseous or mock injection at 30 minutes in two appointments. The first molar and adjacent teeth were pulp tested every 2 minutes for a total of 120 minutes. Success was defined as obtaining two consecutive 80 readings with the electric pulp tester. Success of the initial intraosseous injection was 100% for the first molar. The repeated intraosseous injection mimicked the initial intraosseous injection in terms of pulpal anesthesia and statistically provided another 15 minutes of pulpal anesthesia. In conclusion, using the methodology presented, repeating the intraosseous injection 30 minutes after an initial intraosseous injection will provide an additional 15 minutes of pulpal anesthesia.

  9. Short and long term bystander effect induction by fathead minnows (Pimephales promelas, Rafinesque, 1820) injected with environmentally relevant whole body doses of 226Ra

    International Nuclear Information System (INIS)

    Smith, Richard W.; Seymour, Colin B.; Mothersill, Carmel E.

    2013-01-01

    Bystander effect induction by fathead minnows injected with environmentally relevant doses of 226 Ra was investigated. Twenty four h and 6 months after injection with a single dose of 21, 210 or 2100 μBq, fin tissue samples emitted a pro-apoptotic signal, which reduced the clonogenic survival of an apoptosis sensitive reporter cell line. Twenty four h and 10 weeks after injection explants from non-injected bystander fish, swum with the injected fish, also emitted a pro-apoptotic signal. However 6 months after injection the bystander fish to 21 and 210 μBq injected fish emitted an anti-apoptotic signal. This demonstrates that extremely low dose irradiation can have effects outside of the irradiated fish. This has implications for population and ecosystem responses to contamination. -- Highlights: • Non-injected fish, swum with injected fish, gave the same response for up to 10 weeks. • After 6 months this response by non-injected fish changed to an anti-apoptotic signal. • This shows that 226 Ra contamination can have effects outside of the irradiated fish

  10. TASKA-M - a low cost, near term tandem mirror device for fusion technology testing

    International Nuclear Information System (INIS)

    Badger, B.; Corradini, M.L.; El-Guebaly, L.; Emmert, G.A.; Kulcinski, G.L.; Larsen, E.M.; Maynard, C.W.; Perkins, L.J.; Peterson, R.R.; Plute, K.E.; Santarius, J.F.; Sawan, M.E.; Scharer, J.E.; Sviatoslavsky, I.N.; Sze, D.K.; Vogelsang, W.F.; Wittenberg, L.J.; Leppelmeier, G.W.; Grover, J.M.; Opperman, E.K.; Vogel, M.A.; Borie, E.; Taczanowski, S.; Arendt, F.; Dittrich, H.G.; Fett, T.; Haferkamp, B.; Heinz, W.; Hoelzchen, E.; Kleefeldt, K.; Klingelhoefer, R.; Komarek, P.; Kuntze, M.; Leiste, H.G.; Link, W.; Malang, S.; Manes, B.M.; Maurer, W.; Michael, I.; Mueller, R.A.; Neffe, G.; Schramm, K.; Suppan, A.; Weinberg, D.

    1984-04-01

    TASKA-M (Modifizierte Tandem Spiegelmaschine Karlsruhe) is a study of a dedicated fusion technology device based on the mirror principle, in continuation of the 1981/82 TASKA study. The main objective is to minimize cost while retaining key requirements of neutron flux and fluence for blanket and material development and for component testing in a nuclear environment. Direct costs are reduced to about 400 M$ by dropping reactor-relevant aspects not essential to technology testing: No thermal barrier and electrostatic plugging of the plasma; fusion power of 7 MW at an injected power of 44 MW; tritium supply from external sources. All technologies for operating the machine are expected to be available by 1990; the plasma physics relies on microstabilization in a sloshing ion population. (orig.) [de

  11. Development of Technique for Testing the Long-Term Stability of Silicon Microstrip Detectors

    International Nuclear Information System (INIS)

    Kosinov, A.V.; Maslov, N.I.; Naumov, S.V.; Ovchinnik, V.D.; Starodubtsev, A.F.; Vasiliev, G.P.; Yalovenko, V.I.; Bosisio, L.

    2006-01-01

    An automatic multi-channel set-up prototype for simultaneous testing of the Long-Term Stability (LTS) of more than ten detectors is described. The Inner Tracking System of the ALICE experiment will include about two thousand Double-sided Microstrip Detectors (DSMD). Efficient automatic measurement techniques are crucial for the LTS test, because the corresponding test procedure should be performed on each detector and requires long time, at least two days. By using special adapters for supporting and connecting the bare DSMDs, failing detectors can be screened out before module assembly, thus minimizing the cost. Automated probe stations developed for a special purpose or for microelectronics industry are used for measuring physical static DSMD characteristics and check good-to-bad elements ratio for DSMD. However, automated (or semi-automatic)test benches for studying LTS or testing DSMD long-term stability before developing a detecting module are absent

  12. Notes on power of normality tests of error terms in regression models

    Energy Technology Data Exchange (ETDEWEB)

    Střelec, Luboš [Department of Statistics and Operation Analysis, Faculty of Business and Economics, Mendel University in Brno, Zemědělská 1, Brno, 61300 (Czech Republic)

    2015-03-10

    Normality is one of the basic assumptions in applying statistical procedures. For example in linear regression most of the inferential procedures are based on the assumption of normality, i.e. the disturbance vector is assumed to be normally distributed. Failure to assess non-normality of the error terms may lead to incorrect results of usual statistical inference techniques such as t-test or F-test. Thus, error terms should be normally distributed in order to allow us to make exact inferences. As a consequence, normally distributed stochastic errors are necessary in order to make a not misleading inferences which explains a necessity and importance of robust tests of normality. Therefore, the aim of this contribution is to discuss normality testing of error terms in regression models. In this contribution, we introduce the general RT class of robust tests for normality, and present and discuss the trade-off between power and robustness of selected classical and robust normality tests of error terms in regression models.

  13. Notes on power of normality tests of error terms in regression models

    International Nuclear Information System (INIS)

    Střelec, Luboš

    2015-01-01

    Normality is one of the basic assumptions in applying statistical procedures. For example in linear regression most of the inferential procedures are based on the assumption of normality, i.e. the disturbance vector is assumed to be normally distributed. Failure to assess non-normality of the error terms may lead to incorrect results of usual statistical inference techniques such as t-test or F-test. Thus, error terms should be normally distributed in order to allow us to make exact inferences. As a consequence, normally distributed stochastic errors are necessary in order to make a not misleading inferences which explains a necessity and importance of robust tests of normality. Therefore, the aim of this contribution is to discuss normality testing of error terms in regression models. In this contribution, we introduce the general RT class of robust tests for normality, and present and discuss the trade-off between power and robustness of selected classical and robust normality tests of error terms in regression models

  14. Test Plan for Long-Term Operation of a Ten-Cell High Temperature Electrolysis Stack

    International Nuclear Information System (INIS)

    James E. O'Brien; Carl M. Stoots; J. Stephen Herring

    2008-01-01

    This document defines a test plan for a long-term (2500 Hour) test of a ten-cell high-temperature electrolysis stack to be performed at INL during FY09 under the Nuclear Hydrogen Initiative. This test was originally planned for FY08, but was removed from our work scope as a result of the severe budget cuts in the FY08 NHI Program. The purpose of this test is to evaluate stack performance degradation over a relatively long time period and to attempt to identify some of the degradation mechanisms via post-test examination. This test will be performed using a planar ten-cell Ceramatec stack, with each cell having dimensions of 10 cm x 10 cm. The specific makeup of the stack will be based on the results of a series of shorter duration ten-cell stack tests being performed during FY08, funded by NGNP. This series of tests was aimed at evaluating stack performance with different interconnect materials and coatings and with or without brazed edge rails. The best performing stack from the FY08 series, in which five different interconnect/coating/edge rail combinations were tested, will be selected for the FY09 long-term test described herein

  15. High HIV Prevalence, Suboptimal HIV Testing, and Low Knowledge of HIV-Positive Serostatus Among Injection Drug Users in St. Petersburg, Russia

    Science.gov (United States)

    Toussova, Olga V.; Verevochkin, Sergei V.; Barbour, Russell; Heimer, Robert; Kozlov, Andrei P.

    2011-01-01

    The purpose of this analysis was to estimate human immunodeficiency virus (HIV) prevalence and testing patterns among injection drug users (IDUs) in St. Petersburg, Russia. HIV prevalence among 387 IDUs in the sample was 50%. Correlates of HIV-positive serostatus included unemployment, recent unsafe injections, and history/current sexually transmitted infection. Seventy-six percent had been HIV tested, but only 22% of those who did not report HIV-positive serostatus had been tested in the past 12 months and received their test result. Correlates of this measure included recent doctor visit and having been in prison or jail among men. Among the 193 HIV-infected participants, 36% were aware of their HIV-positive serostatus. HIV prevalence is high and continuing to increase in this population. Adequate coverage of HIV testing has not been achieved, resulting in poor knowledge of positive serostatus. Efforts are needed to better understand motivating and deterring factors for HIV testing in this setting. PMID:18843531

  16. Super long-term creep tests of advanced HP and IP rotor steels

    Energy Technology Data Exchange (ETDEWEB)

    Tchizhik, A.A. [The Polzunov Central Boiler and Turbine Institute, Department the Fatigue Life of Materials for Power Plans Equipment, St. Petersburg (Russian Federation)

    1998-12-31

    A creep model has been developed for predicting the long-term creep behavior, in excess of 200,000 h for advanced materials.The new creep theory is based on a continuum microdamage model and is used to calculate the fields of stress and strain and wedge and cavities damage in critical components of steam and gas turbines. The application of this new model increases the reliability and service life of modern turbines. The accuracy of the model to predict long - term creep behavior, creep ductility was verified using the data bank of super long-term creep tests of advanced materials. (orig.) 12 refs.

  17. Super long-term creep tests of advanced HP and IP rotor steels

    Energy Technology Data Exchange (ETDEWEB)

    Tchizhik, A A [The Polzunov Central Boiler and Turbine Institute, Department the Fatigue Life of Materials for Power Plans Equipment, St. Petersburg (Russian Federation)

    1999-12-31

    A creep model has been developed for predicting the long-term creep behavior, in excess of 200,000 h for advanced materials.The new creep theory is based on a continuum microdamage model and is used to calculate the fields of stress and strain and wedge and cavities damage in critical components of steam and gas turbines. The application of this new model increases the reliability and service life of modern turbines. The accuracy of the model to predict long - term creep behavior, creep ductility was verified using the data bank of super long-term creep tests of advanced materials. (orig.) 12 refs.

  18. Long term test of buffer material at the Aespoe HRL, LOT project. Final report on the A0 test parcel

    International Nuclear Information System (INIS)

    Karnland, Ola; Olsson, Siv; Sanden, Torbjoern; Faelth, Billy; Jansson, Mats; Eriksen, Trygve E.; Svaerdstroem, Kjell; Rosborg, Bo; Muurinen, Arto

    2011-02-01

    In the Swedish repository concept for nuclear waste (KBS-3 concept), the spent nuclear fuel will be stored in copper canisters surrounded by compacted bentonite. The decaying power of the fuel will increase the temperature in the repository which, in combination with the uptake of ground-water, could be expected to produce minor mineralogical changes in the bentonite. The ongoing LOT test series at the Aespoe Hard Rock Laboratory are focused on identifying and quantifying any mineralogical alterations in the bentonite exposed to typical repository-like conditions. Further, buffer-related processes concerning copper corrosion, cation transport, and bacterial survival/activity are studied. In total, the LOT project includes seven test parcels, which contain a central Cu-tube surrounded by cylindrical bentonite blocks to a total diameter of 30 cm as well as temperature, total pressure, water pressure and humidity sensors. In each test parcel, an electrical heater placed inside the copper tube is used to simulate the heat generation from the decaying spent fuel. Three test parcels (S1 to S3) have been exposed to standard KBS-3 conditions (maximum temperature below 100 deg C) and three parcels (A1 to A3) to adverse conditions (maximum temperature below ∼140 deg C). Both the standard and the adverse test series include short term tests (1 to 2 years), medium term tests (> 5 years) and long term tests (> 10 years). The present report concerns an additional short term test, thereby the designation A0, which was exposed to adverse conditions for approximately 1.5 years. Cu-coupons, 134 Cs and 57 Co tracers and specific chemical agents were placed in the bentonite at defined positions. After field exposure, the entire test parcel was released from the rock by overlapping percussion drilling and wire sawing. The parcel was lifted and divided at the test site and the bentonite material was sampled for specified analyses. The main aspects of the various tests and analyses may

  19. Long term test of buffer material at the Aespoe HRL, LOT project. Final report on the A0 test parcel

    Energy Technology Data Exchange (ETDEWEB)

    Karnland, Ola; Olsson, Siv; Sanden, Torbjoern; Faelth, Billy (Clay Technology AB, Lund (Sweden)); Jansson, Mats; Eriksen, Trygve E.; Svaerdstroem, Kjell (KTH Royal Inst. of Technology, Stockholm (Sweden)); Rosborg, Bo (Studsvik AB, Nykoeping (Sweden); Rosborg Consulting, Nykoeping (Sweden)); Muurinen, Arto (VTT, Espoo (Finland))

    2011-02-15

    In the Swedish repository concept for nuclear waste (KBS-3 concept), the spent nuclear fuel will be stored in copper canisters surrounded by compacted bentonite. The decaying power of the fuel will increase the temperature in the repository which, in combination with the uptake of ground-water, could be expected to produce minor mineralogical changes in the bentonite. The ongoing LOT test series at the Aespoe Hard Rock Laboratory are focused on identifying and quantifying any mineralogical alterations in the bentonite exposed to typical repository-like conditions. Further, buffer-related processes concerning copper corrosion, cation transport, and bacterial survival/activity are studied. In total, the LOT project includes seven test parcels, which contain a central Cu-tube surrounded by cylindrical bentonite blocks to a total diameter of 30 cm as well as temperature, total pressure, water pressure and humidity sensors. In each test parcel, an electrical heater placed inside the copper tube is used to simulate the heat generation from the decaying spent fuel. Three test parcels (S1 to S3) have been exposed to standard KBS-3 conditions (maximum temperature below 100 deg C) and three parcels (A1 to A3) to adverse conditions (maximum temperature below approx140 deg C). Both the standard and the adverse test series include short term tests (1 to 2 years), medium term tests (> 5 years) and long term tests (> 10 years). The present report concerns an additional short term test, thereby the designation A0, which was exposed to adverse conditions for approximately 1.5 years. Cu-coupons, 134Cs and 57Co tracers and specific chemical agents were placed in the bentonite at defined positions. After field exposure, the entire test parcel was released from the rock by overlapping percussion drilling and wire sawing. The parcel was lifted and divided at the test site and the bentonite material was sampled for specified analyses. The main aspects of the various tests and analyses

  20. Long-term ETR/INTOR magnet testing in support of the demonstration fusion reactor

    International Nuclear Information System (INIS)

    Herring, J.S.; Shah, V.N.; Rouhani, S.Z.

    1983-01-01

    This study considers ways that the proposed Engineering Test Reactor (ETR), or the proposed International Tokamak Reactor (INTOR), can be used for magnet performance tests that would be useful for the design and operation of the Demonstration Tokamak Power Plant (DEMO). Such testing must not interfere with the main function of the ETR/INTOR as an integrated fusion reactor. A performance test plan for the ETR/INTOR magnets is proposed and appropriate tests on the magnets is proposed and appropriate tests on the magnets for each phase of the ETR/INTOR operation are described. The suggested tests would verify design requirements and monitor long-term changes due to radiation. This paper also summarizes the design and operational performance of existing superconducting magnets and identifies the known failures and their predominant causes

  1. The research of new type stratified water injection process intelligent measurement technology

    Science.gov (United States)

    Zhao, Xin

    2017-10-01

    To meet the needs of injection and development of Daqing Oilfield, the injection of oil from the early stage of general water injection to the subdivision of water is the purpose of improving the utilization degree and the qualified rate of water injection, improving the performance of water injection column and the matching process. Sets of suitable for high water content of the effective water injection technology supporting technology. New layered water injection technology intelligent measurement technology will be more information testing and flow control combined into a unified whole, long-term automatic monitoring of the work of the various sections, in the custom The process has the characteristics of "multi-layer synchronous measurement, continuous monitoring of process parameters, centralized admission data", which can meet the requirement of subdivision water injection, but also realize the automatic synchronization measurement of each interval, greatly improve the efficiency of tiered injection wells to provide a new means for the remaining oil potential.

  2. Long term test-retest reliability of Oswestry Disability Index in male office workers.

    Science.gov (United States)

    Irmak, Rafet; Baltaci, Gul; Ergun, Nevin

    2015-01-01

    The Oswestry Disability Index (ODI) is one of the most common condition specific outcome measures used in the management of spinal disorders. But there is insufficient study on healthy populations and long term test-retest reliability. This is important because healthy populations are often used for control groups in low back pain interventions, and knowing the reliability of the controls affects the interpretation of the findings of these studies. The purpose of this study is to determine the long term test-retest reliability of ODI in office workers. Participants who have no chronic low back pain history were included in study. Subjects were assessed by the Turkish-ODI 2.0 (e-forms) on 1st, 2nd, 4th, 8th, 15th, 30th days to determine the stability of ODI scores over time. The study began with 58 (12 female, 46 male) participants. 36 (3 female, 33 male) participated for the full 30 days. Kolmogorov-Smirnov and Friedman tests were used. Test-retest reliability was evaluated by using nonparametric statistics. All tests were done by using SPSS-11. There was no statistically significant difference among the median scores of each day. (χ= 6.482, p >  0.05). The difference between median score of the days with 1st day was neither statistically nor clinically significant. ODI has long term test re-test reliability in healthy subjects over a 1 month time interval.

  3. Lance water injection tests adjacent to the 281-3H retention basin at the Savannah River Site, Aiken, South Carolina

    International Nuclear Information System (INIS)

    Freifeld, B.; Myer, L.; Moridis, G.; Cook, P.; James, A.; Pellerin, L.; Pruess, K.

    1996-09-01

    A pilot-scale field demonstration of waste isolation using viscous- liquid containment barriers has been planned for the 281-3H retention basin at the Savannah River Site, Aiken, SC. The 281-3H basin is a shallow retention/seepage basin contaminated mainly by radionuclides. The viscous-liquid containment barrier utilizes the permeation of liquid grout to either entomb the contaminants within a monolithic grout structure or to isolate the waste by drastically reducing the permeability, of the soils around the plume. A clear understanding of the hydrogeologic setting of the retention basin is necessary for proper design of the viscous liquid barrier. To aid in the understanding of the hydrogeology of the 281-3H retention basin, and to obtain critical parameters necessary for grout injection design, a series of tests were undertaken in a region immediately adjacent to the basin. The objectives of the LWIT were: 1. To evaluate the general performance of the Lance Injection Technique for grout emplacement at the site, including the range and upper limits of injection pressures, the flow rates applicable for site conditions, as well as the mechanical forces needed for lance penetration. 2. To obtain detailed information on the injectability of the soils immediately adjacent to the H-area retention basin. 3. To identify any high permeability zones suitable for injection and evaluate their spatial distribution. 4. To perform ground penetrating radar (GPR) to gain information on the structure of the soil column and to compare the results with LWIT data. This report will focus on results pertinent to these objectives

  4. Bancroftian filariasis: long-term effect of the DEC provocative day test on microfilaraemia

    DEFF Research Database (Denmark)

    Simonsen, Poul Erik; Meyrowitsch, Dan Wolf; Makunde, W.H.

    1997-01-01

    The diethylcarbamazine (DEC) provocative day test has been widely used for daytime diagnosis of Wuchereria bancrofti infections in areas where microfilariae exhibit nocturnal periodicity. Since DEC is also the primary drug for treatment of bancroftian filariasis, we examined the long term effect...... amicrofilaraemic. No significant reduction of microfilaraemia was observed in the placebo group. The results imply that the DEC provocative day test should not be used as a diagnostic tool in follow-up studies on microfilaraemias....

  5. Integrated dry NO{sub x}/SO{sub 2} emissions control system sodium-based dry sorbent injection test report. Test period: August 4, 1993--July 29, 1995

    Energy Technology Data Exchange (ETDEWEB)

    Smith, R.A.; Shimoto, G.H.; Muzio, L.J. [Fossil Energy Research Corp., Laguna Hills, CA (United States); Hunt, T. [Public Service Co. of Colorado, Denver, CO (United States)

    1997-04-01

    The project goal is to demonstrate up to 70% reductions in NOx and SO{sub 2} emissions through the integration of: (1) down-fired low-NOx burners with overfire air; (2) Selective Non-Catalytic Reduction (SNCR) for additional NOx removal; and (3) dry sorbent injection and duct humidification for SO{sub 2} removal. This report documents the sixth phase of the test program, where the performance of dry sorbent injection with sodium compounds was evaluated as a SO{sub 2} removal technique. Dry sorbent injection was performed in-duct downstream of the air heater (ahead of the fabric filter), as well as at a higher temperature location between the economizer and air heater. Two sodium compounds were evaluated during this phase of testing: sodium sesquicarbonate and sodium bicarbonate. In-duct sodium injection with low levels of humidification was also investigated. This sixth test phase was primarily focused on a parametric investigation of sorbent type and feed rate, although boiler load and sorbent preparation parameters were also varied.

  6. Safety assessment of the SMART design during SBLOCA tests using the high pressure safety injection pump of the SMART-ITL facility

    International Nuclear Information System (INIS)

    Bae, Hwang; Ryu, Sung Uk; Jeon, Byong-Guk; Yang, Jin-Hwa; Yoon, Eun-Koo; Shin, Yong-Cheol; Min, Kyoung-Ho; Park, Jong-Kuk; Choi, Nam-Hyun; Bang, Yun-Gon; Seo, Chan-Jong; Yi, Sung-Jae; Park, Hyun-Sik

    2016-01-01

    SMART is a small-sized integral pressurized light water reactor designed by the Korea Atomic Energy Research Institute (KAERI) from 1997 and received standard design approval (SDA) by the Korean regulatory body in July 2012. Single reactor pressure vessel contains all of the main components including a pressurizer (PZR), steam generators (SG) and reactor coolant pumps (RCP) without any large-size pipes. Several tests to verify a safety and performance of SMART design were carried out. This paper introduces a comparison with three SBLOCA tests. Overall thermal-hydraulic phenomena were observed and showed a traditional trend to decrease a system pressure and temperature. A collapsed water level of the hot side indicated that the safety injection system was successfully operated to recover the reactor coolant system (RCS) and protect the core uncover. An SBLOCA test simulating a guillotine break on the SIS, SCS, and PSV was performed. It was enough to keep a steady-state condition before the SBLOCA test begins. An actuation signal as the boundary condition was properly simulated during the transient test. The scenarios of the SBLOCA in the SMART design were reproduced well using the SMART-ITL facility. The safety injection is effective to protect the core uncover as well as to cool down the RCS. All of the measured parameters show reasonable behaviors

  7. Safety assessment of the SMART design during SBLOCA tests using the high pressure safety injection pump of the SMART-ITL facility

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Hwang; Ryu, Sung Uk; Jeon, Byong-Guk; Yang, Jin-Hwa; Yoon, Eun-Koo; Shin, Yong-Cheol; Min, Kyoung-Ho; Park, Jong-Kuk; Choi, Nam-Hyun; Bang, Yun-Gon; Seo, Chan-Jong; Yi, Sung-Jae; Park, Hyun-Sik [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    SMART is a small-sized integral pressurized light water reactor designed by the Korea Atomic Energy Research Institute (KAERI) from 1997 and received standard design approval (SDA) by the Korean regulatory body in July 2012. Single reactor pressure vessel contains all of the main components including a pressurizer (PZR), steam generators (SG) and reactor coolant pumps (RCP) without any large-size pipes. Several tests to verify a safety and performance of SMART design were carried out. This paper introduces a comparison with three SBLOCA tests. Overall thermal-hydraulic phenomena were observed and showed a traditional trend to decrease a system pressure and temperature. A collapsed water level of the hot side indicated that the safety injection system was successfully operated to recover the reactor coolant system (RCS) and protect the core uncover. An SBLOCA test simulating a guillotine break on the SIS, SCS, and PSV was performed. It was enough to keep a steady-state condition before the SBLOCA test begins. An actuation signal as the boundary condition was properly simulated during the transient test. The scenarios of the SBLOCA in the SMART design were reproduced well using the SMART-ITL facility. The safety injection is effective to protect the core uncover as well as to cool down the RCS. All of the measured parameters show reasonable behaviors.

  8. THE RHIC INJECTION SYSTEM.

    Energy Technology Data Exchange (ETDEWEB)

    FISCHER,W.; GLENN,J.W.; MACKAY,W.W.; PTITSIN,V.; ROBINSON,T.G.; TSOUPAS,N.

    1999-03-29

    The RHIC injection system has to transport beam from the AGS-to-RHIC transfer line onto the closed orbits of the RHIC Blue and Yellow rings. This task can be divided into three problems. First, the beam has to be injected into either ring. Second, once injected the beam needs to be transported around the ring for one turn. Third, the orbit must be closed and coherent beam oscillations around the closed orbit should be minimized. We describe our solutions for these problems and report on system tests conducted during the RHIC Sextant test performed in 1997. The system will be fully commissioned in 1999.

  9. Testing gravitational-wave searches with numerical relativity waveforms: results from the first Numerical INJection Analysis (NINJA) project

    International Nuclear Information System (INIS)

    Aylott, Benjamin; Baker, John G; Camp, Jordan; Centrella, Joan; Boggs, William D; Buonanno, Alessandra; Boyle, Michael; Buchman, Luisa T; Chu, Tony; Brady, Patrick R; Brown, Duncan A; Bruegmann, Bernd; Cadonati, Laura; Campanelli, Manuela; Faber, Joshua; Chatterji, Shourov; Christensen, Nelson; Diener, Peter; Dorband, Nils; Etienne, Zachariah B

    2009-01-01

    The Numerical INJection Analysis (NINJA) project is a collaborative effort between members of the numerical relativity and gravitational-wave data analysis communities. The purpose of NINJA is to study the sensitivity of existing gravitational-wave search algorithms using numerically generated waveforms and to foster closer collaboration between the numerical relativity and data analysis communities. We describe the results of the first NINJA analysis which focused on gravitational waveforms from binary black hole coalescence. Ten numerical relativity groups contributed numerical data which were used to generate a set of gravitational-wave signals. These signals were injected into a simulated data set, designed to mimic the response of the initial LIGO and Virgo gravitational-wave detectors. Nine groups analysed this data using search and parameter-estimation pipelines. Matched filter algorithms, un-modelled-burst searches and Bayesian parameter estimation and model-selection algorithms were applied to the data. We report the efficiency of these search methods in detecting the numerical waveforms and measuring their parameters. We describe preliminary comparisons between the different search methods and suggest improvements for future NINJA analyses.

  10. Subcutaneous Injections

    DEFF Research Database (Denmark)

    Thomsen, Maria

    This thesis is about visualization and characterization of the tissue-device interaction during subcutaneous injection. The tissue pressure build-up during subcutaneous injections was measured in humans. The insulin pen FlexTouchr (Novo Nordisk A/S) was used for the measurements and the pressure ...

  11. Hydromorphone Injection

    Science.gov (United States)

    ... anyone else to use your medication. Store hydromorphone injection in a safe place so that no one else can use it accidentally or on purpose. Keep track of how much medication is left so ... with hydromorphone injection may increase the risk that you will develop ...

  12. Ketorolac Injection

    Science.gov (United States)

    ... an older adult, you should know that ketorolac injection is not as safe as other medications that can be used to treat your condition. Your doctor may choose to prescribe a different medication ... to ketorolac injection.Your doctor or pharmacist will give you the ...

  13. Paclitaxel Injection

    Science.gov (United States)

    (pak'' li tax' el)Paclitaxel injection must be given in a hospital or medical facility under the supervision of a doctor who is experienced in giving chemotherapy medications for cancer.Paclitaxel injection may cause a large decrease in the number of white blood cells (a type of blood cell ...

  14. Comparison of Microbial Community Compositions of Injection and Production Well Samples in a Long-Term Water-Flooded Petroleum Reservoir

    Science.gov (United States)

    Ren, Hong-Yan; Zhang, Xiao-Jun; Song, Zhi-yong; Rupert, Wieger; Gao, Guang-Jun; Guo, Sheng-xue; Zhao, Li-Ping

    2011-01-01

    Water flooding plays an important role in recovering oil from depleted petroleum reservoirs. Exactly how the microbial communities of production wells are affected by microorganisms introduced with injected water has previously not been adequately studied. Using denaturing gradient gel electrophoresis (DGGE) approach and 16S rRNA gene clone library analysis, the comparison of microbial communities is carried out between one injection water and two production waters collected from a working block of the water-flooded Gudao petroleum reservoir located in the Yellow River Delta. DGGE fingerprints showed that the similarities of the bacterial communities between the injection water and production waters were lower than between the two production waters. It was also observed that the archaeal composition among these three samples showed no significant difference. Analysis of the 16S rRNA gene clone libraries showed that the dominant groups within the injection water were Betaproteobacteria, Gammaproteobacteria and Methanomicrobia, while the dominant groups in the production waters were Gammaproteobacteria and Methanobacteria. Only 2 out of 54 bacterial operational taxonomic units (OTUs) and 5 out of 17 archaeal OTUs in the injection water were detected in the production waters, indicating that most of the microorganisms introduced by the injection water may not survive to be detected in the production waters. Additionally, there were 55.6% and 82.6% unique OTUs in the two production waters respectively, suggesting that each production well has its specific microbial composition, despite both wells being flooded with the same injection water. PMID:21858049

  15. Field Test Program for Long-Term Operation of a COHPAC System for Removing Mercury from Coal-Fired Flue Gas

    Energy Technology Data Exchange (ETDEWEB)

    C. Jean Bustard; Charles Lindsey; Paul Brignac

    2006-05-01

    This document provides a summary of the full-scale demonstration efforts involved in the project ''Field Test Program for Long-Term Operation of a COHPAC{reg_sign} System for Removing Mercury from Coal-Fired Flue Gas''. The project took place at Alabama Power's Plant Gaston Unit 3 and involved the injection of sorbent between an existing particulate collector (hot-side electrostatic precipitators) and a COHPAC{reg_sign} fabric filter (baghouse) downstream. Although the COHPAC{reg_sign} baghouse was designed originally for polishing the flue gas, when activated carbon injection was added, the test was actually evaluating the EPRI TOXECON{reg_sign} configuration. The results from the baseline tests with no carbon injection showed that the cleaning frequency in the COHPAC{reg_sign} unit was much higher than expected, and was above the target maximum cleaning frequency of 1.5 pulses/bag/hour (p/b/h), which was used during the Phase I test in 2001. There were times when the baghouse was cleaning continuously at 4.4 p/b/h. In the 2001 tests, there was virtually no mercury removal at baseline conditions. In this second round of tests, mercury removal varied between 0 and 90%, and was dependent on inlet mass loading. There was a much higher amount of ash exiting the electrostatic precipitators (ESP), creating an inlet loading greater than the design conditions for the COHPAC{reg_sign} baghouse. Tests were performed to try to determine the cause of the high ash loading. The LOI of the ash in the 2001 baseline tests was 11%, while the second baseline tests showed an LOI of 17.4%. The LOI is an indication of the carbon content in the ash, which can affect the native mercury uptake, and can also adversely affect the performance of ESPs, allowing more ash particles to escape the unit. To overcome this, an injection scheme was implemented that balanced the need to decrease carbon injection during times when inlet loading to the baghouse was high and

  16. Combined Case of Blood-Injury-Injection Phobia and Social Phobia: Behavior Therapy Management and Effectiveness through Tilt Test

    Directory of Open Access Journals (Sweden)

    Fotini Ferenidou

    2012-01-01

    Full Text Available The efficacy of behavior therapy based mainly on real-life exposure situations as well as applied tension was examined for a combined case of blood-injury-injection (BII phobia and social anxiety disorder. Treatment involved 28 behavior therapy sessions, while applied tension technique was also described and practiced. The specific contribution of social skills techniques, fantasy, and real-life situations exposure was examined in a single case design. The subject was a 39-year-old male with anxiety symptoms when confronting an audience, as well as symptoms of the autonomic nervous system (bradycardia and syncope, which were better explained by BII. All self-report measures regarding fear, social phobia, and anxiety were reduced after behavior therapy and remained maintained at followup, while BII decreased further after applied tension techniques. The contribution of behavior therapy to the overall outcome of the case is considered significant for many reasons that are discussed in the pape.

  17. Simulation of long-term behavior in HLW near-field by centrifugal model test. Part 4. Model test of coupled THM processes in isotropic stress conditions using heatable overpack

    International Nuclear Information System (INIS)

    Nishimoto, Soshi; Okada, Tetsuji; Sawada, Masataka

    2014-01-01

    We demonstrated the equivalent long-term behavior in the near-field of a geological repository for high level radioactive waste disposal, using the centrifugal near-field model test under the coupled thermo-hydraulic-mechanical condition. The model consisted of a sedimentary bedrock, buffer, and heating type model overpack, and was enclosed within a pressure vessel. Tests were conducted with a centrifugal force field of 30 G under isotropic stress-constrain conditions with confining pressures and injection of pore water. The temperature condition of the overpack was constantly 95°C. As the result, the values showed similar behaviors to that of the normal temperature tests partially. However, the different behaviors were measured such as the displacement of overpack change from the settlement to the heave, the extreme drop in the soil pressure of the buffer and the strain of side wall of bedrock change from the tension to the compression after injecting pore water of hundreds hours. In addition, the flow rate of the injection pore water suddenly changed after hundreds of hours. Furthermore, the density of the buffer was lower than that of the normal temperature tests by X-ray CT imaging in the post-tests. We infer that the high temperature overpack influenced the stiffness and the pore water distribution of the buffer, and the density and the soil pressure of the buffer decreased. As a result of the change of stiffness in the disposal hole (buffer), the tendency to the strain of the surrounding bedrock and the displacement of the overpack changed. (author)

  18. Long-term repeatability of the skin prick test is high when supported by history or allergen-sensitivity tests

    DEFF Research Database (Denmark)

    Bødtger, Uffe; Jacobsen, C R; Poulsen, L K

    2003-01-01

    subjects. An SPT was positive when > or =3 mm, and repeatable if either persistently positive or negative. Clinical sensitivity to birch pollen was used as model for inhalation allergy, and was investigated at inclusion and at study termination by challenge tests, intradermal test, titrated SPT and Ig......E measurements. Birch pollen symptoms were confirmed in diaries. RESULTS: The repeatability of a positive SPT was 67%, increasing significantly to 100% when supported by the history. When not supported by history, the presence of specific IgE was significantly associated with a repeatable SPT. Allergen....... CONCLUSION: SPT changes are clinically relevant. Further studies using other allergens are needed. Long-term repeatability of SPT is high in the presence of a supportive history....

  19. Safe and successful endoscopic initial treatment and long-term eradication of gastric varices by endoscopic ultrasound-guided Histoacryl (N-butyl-2-cyanoacrylate) injection

    OpenAIRE

    Gubler, Christoph; Bauerfeind, Peter

    2014-01-01

    OBJECTIVE: Optimal endoscopic treatment of gastric varices is still not standardized nowadays. Actively bleeding varices may prohibit a successful endoscopic injection therapy of Histoacryl® (N-butyl-2-cyanoacrylate). Since 2006, we have treated gastric varices by standardized endoscopic ultrasound (EUS) guided Histoacryl injection therapy without severe adverse events. MATERIAL AND METHODS: We present a large single-center cohort over 7 years with a standardized EUS-guided sclerotherapy o...

  20. Technical description of the NRC long-term whole-rod and crud performance test

    International Nuclear Information System (INIS)

    Einziger, R.E.; Fish, R.L.; Knecht, R.L.

    1982-09-01

    Westinghouse Hanford Company (WHC) and EG and G-Idaho are jointly conducting a long-term, low-temperature, spent-fuel, whole rod and crud behavior test to provide the Nuclear Regulatory Commission (NRC) with information to assist in the licensing of light water reactor (LWR) spent-fuel, dry storage facilities. Readily available fuel rods from an H.B. Robinson Unit 2 (PWR) fuel assembly and a Peach Bottom-II (BWR) fuel assembly were selected for use in the 50-month test. Both intact and defected rods will be tested in inert and oxidizing atmospheres. A 230 0 C test temperature was selected for the first 10-month run. Both nondestructive and destructive examinations are planned to characterize the fuel rod behavior during the 5-y test. Four interim examinations and a final examination will be conducted. Crud spallation behavior will be investigated by sampling the crud particulate from the test capsules at each of the four interim examinations and at the end of the test. The background to whole rod testing, description of rod breach mechanisms, and a detailed description of the test are presented in this document

  1. Practical experience applied to the design of injection and sample manifolds to perform in-place surveillance tests according to ANSI/ASME N-510

    Energy Technology Data Exchange (ETDEWEB)

    Banks, E.M.; Wikoff, W.O.; Shaffer, L.L. [NUCON International, Inc., Columbus, OH (United States)

    1997-08-01

    At the current level of maturity and experience in the nuclear industry, regarding testing of air treatment systems, it is now possible to design and qualify injection and sample manifolds for most applications. While the qualification of sample manifolds is still in its infancy, injection manifolds have reached a mature stage that helps to eliminate the {open_quotes}hit or miss{close_quotes} type of design. During the design phase, manifolds can be adjusted to compensate for poor airflow distribution, laminar flow conditions, and to take advantage of any system attributes. Experience has shown that knowing the system attributes before the design phase begins is an essential element to a successful manifold design. The use of a spreadsheet type program commonly found on most personal computers can afford a greater flexibility and a reduction in time spent in the design phase. The experience gained from several generations of manifold design has culminated in a set of general design guidelines. Use of these guidelines, along with a good understanding of the type of testing (theoretical and practical), can result in a good manifold design requiring little or no field modification. The requirements for manifolds came about because of the use of multiple banks of components and unconventional housing inlet configurations. Multiple banks of adsorbers and pre and post HEPA`s required that each bank be tested to insure that each one does not exceed a specific allowable leakage criterion. 5 refs., 5 figs., 1 tab.

  2. Using 25 Percent / 75 Percent ATJ/JP-8 Blend Rotary Fuel Injection Pump Wear Testing at Elevated Temperature

    Science.gov (United States)

    2015-09-01

    approximately 9.95mm • C- Blade height approximately 12.66mm D E F UNCLASSIFIED 35 5.5 FUEL INJECTOR RESULTS Fuel injector nozzle tests were...performed in accordance with procedures set forth in an approved 6.5LT diesel engine manual using diesel nozzle tester J 29075B. Nozzle testing is...1500 psig minimum. The specified nozzle leakage test involves pressurizing the injector nozzle to 1400 psig and holding for 10 seconds – no fuel

  3. Long-term results of interventional treatment of large unresectable hepatocellular carcinoma (HCC): significant survival benefit from combined transcatheter arterial chemoembolization (TACE) and percutaneous ethanol injection (PEI) compared to TACE monotherapy

    International Nuclear Information System (INIS)

    Lubienski, A.; Bitsch, R.G.; Grenacher, L.; Kauffmann, G.W.; Schemmer, P.; Duex, M.

    2004-01-01

    Purpose: A retrospective analysis of long-term efficacy of combined transcatheter arterial chemoembolization (TACE) and percutaneous ethanol injection (PEI) and TACE monotherapy was conducted in patients with large, non-resectable hepatocellular carcinoma (HCC). Methods and Materials: Fifty patients with large, unresectable HCC lesions underwent selective TACE. Liver cirrhosis was present in 42 patients, due to alcohol abuse (n = 22) and viral infection (n = 17). In three patients, the underlying cause for liver cirrhosis remained unclear. Child A cirrhosis was found in 22 and Child B cirrhosis in 20 patients. Repeated and combined TACE and PEI were performed in 22 patients and repeated TACE monotherapy was performed in 28 patients. Survival and complication rates were determined and compared. Results: The 6-, 12-, 24- and 36-month survival rates were 61%, 21%, 4%, and 4% for TACE monotherapy and 77%, 55%, 39% and 22% for combined TACE and PEI (Kaplan-Meier method). The kind of treatment significantly affected the survival rate (p=0.002 log-rank test). Severe side effects were present in two patients of the monotherapy group and in three patients of the combination therapy group. (orig.)

  4. Proposed retrofit of HEPA filter plenums with injection and sampling manifolds for in-place filter testing

    Energy Technology Data Exchange (ETDEWEB)

    Fretthold, J.K. [EG& G Rocky Flats, Inc., Golden, CO (United States)

    1995-02-01

    The importance of testing HEPA filter exhaust plenums with consideration for As Low as Reasonably Achievable (ALARA) will require that new technology be applied to existing plenum designs. HEPA filter testing at Rocky Flats has evolved slowly due to a number of reasons. The first plenums were built in the 1950`s, preceding many standards. The plenums were large, which caused air dispersal problems. The systems were variable air flow. Access to the filters was difficult. The test methods became extremely conservative. Changes in methods were difficult to make. The acceptance of new test methods has been made in recent years with the change in plant mission and the emphasis on worker safety.

  5. Double-Ended Break Test of an 8.5 inch Direct Vessel Injection Line using the ATLAS

    International Nuclear Information System (INIS)

    Choi, Ki Yong; Kang, Kyoung Ho; Kim, Bok Deuk; Kim, Yeon Sik; Min, Kyoung Ho; Park, Choon Kyoung; Park, Hyun Sik; Baek, Won Pil; Cho, Seok; Choi, Nam Hyun

    2010-01-01

    A thermal-hydraulic integral effect test facility, ATLAS (Advanced Thermal-hydraulic Test Loop for Accident Simulation), has been constructed at the Korea Atomic Energy Research Institute (KAERI). It is a 1/2 reduced height and 1/288-volume scaled test facility with respect to the APR1400, an evolutionary pressurized water reactor developed by the Korean industry. In 2008, an integral effect test for simulating a guillotine break of a DVI line of the APR1400 was carried out as the first DVI test item, named as SB-DVI-03, on May, 2008. With an improvement on the break flow measuring system, the second DVI test for a guillotine break of a DVI line of the APR1400, named as SB-DVI-08, was conducted for repeatability. The present data is the first integral effect test data of its kind for simulating a DVI line break accident. It will help in understanding the thermal hydraulic phenomena occurring during the DVI line break accident. A post-test calculation was performed with a best-estimate safety analysis code MARS 3.1 to examine its prediction capability and to identify any code deficiencies for the thermal hydraulic phenomena occurring during the DVI line break accidents. The present integral effect test data will be used to validate the current safety analysis methodology for the DVI line break accident

  6. Temozolomide Injection

    Science.gov (United States)

    ... balance or coordination fainting dizziness hair loss insomnia memory problems pain, itching, swelling, or redness in the place where the medication was injected changes in vision Some side effects can be serious. If you ...

  7. Buprenorphine Injection

    Science.gov (United States)

    ... injection is in a class of medications called opiate partial agonists. It works to prevent withdrawal symptoms ... help. If the victim has collapsed, had a seizure, has trouble breathing, or can't be awakened, ...

  8. Risperidone Injection

    Science.gov (United States)

    ... release (long-acting) injection is used to treat schizophrenia (a mental illness that causes disturbed or unusual ... may help control your symptoms but will not cure your condition. Continue to keep appointments to receive ...

  9. Haloperidol Injection

    Science.gov (United States)

    ... haloperidol extended-release injection are used to treat schizophrenia (a mental illness that causes disturbed or unusual ... may help control your symptoms but will not cure your condition. Continue to keep appointments to receive ...

  10. Omalizumab Injection

    Science.gov (United States)

    ... injection is used to decrease the number of asthma attacks (sudden episodes of wheezing, shortness of breath, and ... about how to treat symptoms of a sudden asthma attack. If your asthma symptoms get worse or if ...

  11. Cefotaxime Injection

    Science.gov (United States)

    ... is in a class of medications called cephalosporin antibiotics. It works by killing bacteria.Antibiotics such as cefotaxime injection will not work for colds, flu, or other viral infections. Using ...

  12. Cefuroxime Injection

    Science.gov (United States)

    ... is in a class of medications called cephalosporin antibiotics. It works by killing bacteria.Antibiotics such as cefuroxime injection will not work for colds, flu, or other viral infections. Using ...

  13. Doripenem Injection

    Science.gov (United States)

    ... is in a class of medications called carbapenem antibiotics. It works by killing bacteria.Antibiotics such as doripenem injection will not work for colds, flu, or other viral infections. Taking ...

  14. Daptomycin Injection

    Science.gov (United States)

    ... in a class of medications called cyclic lipopeptide antibiotics. It works by killing bacteria.Antibiotics such as daptomycin injection will not work for treating colds, flu, or other viral infections. ...

  15. Ceftaroline Injection

    Science.gov (United States)

    ... is in a class of medications called cephalosporin antibiotics. It works by killing bacteria.Antibiotics such as ceftaroline injection will not work for colds, flu, or other viral infections. Using ...

  16. Aztreonam Injection

    Science.gov (United States)

    ... is in a class of medications called carbapenem antibiotics. It works by killing bacteria.Antibiotics such as aztreonam injection will not work for colds, flu, or other viral infections. Taking ...

  17. Cefazolin Injection

    Science.gov (United States)

    ... is in a class of medications called cephalosporin antibiotics. It works by killing bacteria.Antibiotics such as cefazolin injection will not work for colds, flu, or other viral infections. Taking ...

  18. Ceftazidime Injection

    Science.gov (United States)

    ... is in a class of medications called cephalosporin antibiotics. It works by killing bacteria.Antibiotics such as ceftazidime injection will not work for colds, flu, or other viral infections. Using ...

  19. Cefotetan Injection

    Science.gov (United States)

    ... is in a class of medications called cephalosporin antibiotics. It works by killing bacteria.Antibiotics such as cefotetan injection will not work for colds, flu, or other viral infections. Using ...

  20. Cefoxitin Injection

    Science.gov (United States)

    ... is in a class of medications called cephamycin antibiotics. It works by killing bacteria.Antibiotics such as cefoxitin injection will not work for colds, flu, or other viral infections. Taking ...

  1. Tigecycline Injection

    Science.gov (United States)

    ... is in a class of medications called tetracycline antibiotics. It works by killing bacteria that cause infection.Antibiotics such as tigecycline injection will not work for colds, flu, or other viral infections. Using ...

  2. Ertapenem Injection

    Science.gov (United States)

    ... is in a class of medications called carbapenem antibiotics. It works by killing bacteria.Antibiotics such as ertapenem injection will not work for colds, flu, or other viral infections. Taking ...

  3. Ceftriaxone Injection

    Science.gov (United States)

    ... is in a class of medications called cephalosporin antibiotics. It works by killing bacteria.Antibiotics such as ceftriaxone injection will not work for colds, flu, or other viral infections.Using ...

  4. Cefepime Injection

    Science.gov (United States)

    ... is in a class of medications called cephalosporin antibiotics. It works by killing bacteria.Antibiotics such as cefepime injection will not work for colds, flu, or other viral infections. Using ...

  5. Telavancin Injection

    Science.gov (United States)

    ... is in a class of medications called lipoglycopeptide antibiotics. It works by killing bacteria that cause infection.Antibiotics such as telavancin injection will not work for colds, flu, or other viral infections. Using ...

  6. Doxycycline Injection

    Science.gov (United States)

    ... is in a class of medications called tetracycline antibiotics. It works by killing bacteria that cause infections.Antibiotics such as doxycycline injection will not work for colds, flu, or other viral infections. Taking ...

  7. Vancomycin Injection

    Science.gov (United States)

    ... is in a class of medications called glycopeptide antibiotics. It works by killing bacteria that cause infections.Antibiotics such as vancomycin injection will not work for colds, flu, or other viral infections. Taking ...

  8. Octreotide Injection

    Science.gov (United States)

    ... carton and protect it from light. Dispose of multi-dose vials of the immediate-release injection 14 ... and immediately place the medication in a safe location – one that is up and away and out ...

  9. Moxifloxacin Injection

    Science.gov (United States)

    ... tendon area, or inability to move or to bear weight on an affected area.Using moxifloxacin injection ... muscle weakness) and cause severe difficulty breathing or death. Tell your doctor if you have myasthenia gravis. ...

  10. Delafloxacin Injection

    Science.gov (United States)

    ... a tendon area, or inability to move or bear weight on an affected area.Using delafloxacin injection ... muscle weakness) and cause severe difficulty breathing or death. Tell your doctor if you have myasthenia gravis. ...

  11. Levofloxacin Injection

    Science.gov (United States)

    ... tendon area, or inability to move or to bear weight on an affected area.Using levofloxacin injection ... muscle weakness) and cause severe difficulty breathing or death. Tell your doctor if you have myasthenia gravis. ...

  12. Ciprofloxacin Injection

    Science.gov (United States)

    ... a tendon area, or inability to move or bear weight on an affected area.Using ciprofloxacin injection ... muscle weakness) and cause severe difficulty breathing or death. Tell your doctor if you have myasthenia gravis. ...

  13. Alirocumab Injection

    Science.gov (United States)

    ... 9 (PCSK9) inhibitor monoclonal antibodies. It works by blocking the production of LDL cholesterol in the body ... hives difficulty breathing or swallowing swelling of the face, throat, tongue, lips, and eyes Alirocumab injection may ...

  14. Evolocumab Injection

    Science.gov (United States)

    ... 9 (PCSK9) inhibitor monoclonal antibody. It works by blocking the production of LDL cholesterol in the body ... hives difficulty breathing or swallowing swelling of the face, throat, tongue, lips, and eyes Evolocumab injection may ...

  15. Acyclovir Injection

    Science.gov (United States)

    ... It is also used to treat first-time genital herpes outbreaks (a herpes virus infection that causes sores ... in the body. Acyclovir injection will not cure genital herpes and may not stop the spread of genital ...

  16. Butorphanol Injection

    Science.gov (United States)

    ... Butorphanol is in a class of medications called opioid agonist-antagonists. It works by changing the way ... suddenly stop using butorphanol injection, you may experience withdrawal symptoms such as nervousness, agitation, shakiness, diarrhea, chills, ...

  17. An Evaluation of the Carbon Sequestration Potential of the Cambro-Ordovician Strata of the Illinois and Michigan Basins. Part 1. Evaluation of Phase 2 CO2 Injection Testing in the Deep Saline Gunter Sandstone Reservoir (Cambro-Ordovician Knox Group), Marvin Blan No. 1 Hancock County, Kentucky Part 2. Time-lapse Three-Dimensional Vertical Seismic Profile (3D-VSP) of Sequestration Target Interval with Injected Fluids

    Energy Technology Data Exchange (ETDEWEB)

    Bowersox, Richard [Univ. of Illinois, Champaign, IL (United States); Hickman, John [Univ. of Illinois, Champaign, IL (United States); Leetaru, Hannes [Univ. of Illinois, Champaign, IL (United States)

    2012-12-20

    Part 1 of this report focuses on results of the western Kentucky carbon storage test, and provides a basis for evaluating injection and storage of supercritical CO2 in Cambro-Ordovician carbonate reservoirs throughout the U.S. Midcontinent. This test demonstrated that the Cambro- Ordovician Knox Group, including the Beekmantown Dolomite, Gunter Sandstone, and Copper Ridge Dolomite in stratigraphic succession from shallowest to deepest, had reservoir properties suitable for supercritical CO2 storage in a deep saline reservoir hosted in carbonate rocks, and that strata with properties sufficient for long-term confinement of supercritical CO2 were present in the deep subsurface. Injection testing with brine and CO2 was completed in two phases. The first phase, a joint project by the Kentucky Geological Survey and the Western Kentucky Carbon Storage Foundation, drilled the Marvin Blan No. 1 carbon storage research well and tested the entire Knox Group section in the open borehole – including the Beekmantown Dolomite, Gunter Sandstone, and Copper Ridge Dolomite – at 1152–2255 m, below casing cemented at 1116 m. During Phase 1 injection testing, most of the 297 tonnes of supercritical CO2 was displaced into porous and permeable sections of the lowermost Beekmantown below 1463 m and Gunter. The wellbore was then temporarily abandoned with a retrievable bridge plug in casing at 1105 m and two downhole pressure-temperature monitoring gauges below the bridge plug pending subsequent testing. Pressure and temperature data were recorded every minute for slightly more than a year, providing a unique record of subsurface reservoir conditions in the Knox. In contrast, Phase 2 testing, this study, tested a mechanically-isolated dolomitic-sandstone interval in the Gunter.

  18. Testing for long-range dependence in the Brazilian term structure of interest rates

    International Nuclear Information System (INIS)

    Cajueiro, Daniel O.; Tabak, Benjamin M.

    2009-01-01

    This paper presents empirical evidence of fractional dynamics in interest rates for different maturities for Brazil. A variation of a newly developed test for long-range dependence, the V/S statistic, with a post-blackening bootstrap is employed. Results suggest that Brazilian interest rates possess strong long-range dependence in volatility, even when considering the structural break in 1999. These findings imply that the development of policy models that give rise to long-range dependence in interest rates' volatility could be very useful. The long-short-term interest rates spread has strong long-range dependence, which suggests that traditional tests of expectation hypothesis of the term structure of interest rates may be misspecified.

  19. Environmental test program for superconducting materials and devices. Mid-Term Report, May 1990 - Jun. 1991

    International Nuclear Information System (INIS)

    Haertling, G.; Randolph, H.; Hsi, Chi-Shiung; Verbelyi, D.

    1991-07-01

    This report is divided into two parts. The first dealing with work involved with Clemson University and the second with the results from Westinghouse/Savannah River. Both areas of work involved low noise, low thermal conductivity superconducting grounding links used in the NASA-sponsored Spectroscopy of the Atmosphere using Far Infrared Emission (SAFIRE) Project. Clemson prepared the links from YBa2Cu3O(7-x) superconductor tape that was mounted on a printed circuit board and encapsulated with epoxy resin. The Clemson program includes temperature vs. resistance, liquid nitrogen immersion, water immersion, thermal cycling, humidity, and radiation testing. The evaluation of the links under a long term environmental test program is described. The Savannah River program includes gamma irradiation, vibration, and long-term evaluation. The progress made in these evaluations is discussed

  20. Test plan for long-term, low-temperature oxidation of spent fuel, Series 1

    International Nuclear Information System (INIS)

    Einziger, R.E.

    1986-06-01

    Preliminary studies indicated the need for more spent fuel oxidation data in order to determine the probable behavior of spent fuel in a tuff repository. Long-term, low-temperature testing was recommended in a comprehensive technical approach to: (1) confirm the findings of the short-term thermogravimetric analyses scoping experiments; (2) evaluate the effects of variables such as burnup, atmospheric moisture and fuel type on the oxidation rate; and (3) extend the oxidation data base ot representative repository temperatures and better define the temperature dependence of the operative oxidation mechanisms. This document presents the Series 1 test plan to study, on a large number of samples, the effects of atmospheric moisture and temperature on oxidation rate and phase formation. Tests will run for up to two years, use characterized fragmented, and pulverized fuel samples, cover a temperature range of 110 0 C to 175 0 C and be conducted with an atmospheric moisture content rangeing from 0 C to approx. 80 0 C dew point. After testing, the samples will be examined and made available for leaching testing

  1. Review of short-term screening tests for mutagens, toxigens, and carcinogens

    Energy Technology Data Exchange (ETDEWEB)

    Carney, H.J.; Hass, B.S.

    1979-07-01

    In order to test the thousands of man-made chemicals in the environment for carcinogenic and genetic hazards, a multitude of short-term screening tests has been developed to complement long-term mammalian bioassays and epidemiological studies. These tests cover a broad spectrum of organisms, and include the use of naked and viral nucleic acids, bacteria, fungi, higher plants, insects in vitro mammalian cell cultures (cell transformation, cell-mediated mutagenesis, DNA repair, and chromosome aberration tests) and live mammals. Assay end points include effects on nucleic acids, DNA repair synthesis, point or gene mutation, structural and numerical chromosome aberrations, cytological alterations, and in vitro cell transformation. The present review describes and compares these assays. In addition, it discusses their historical development, the problems and limitations associated with their use, and their implementation in comprehensive testing programs. It is intended to provide overview and specific information to the laboratory that is in the process of establishing genetic toxicological systems. (The literature is reviewed to January 1978.)

  2. Diesel fuel long term storage and treatment- recommended tests and practices (U)

    Energy Technology Data Exchange (ETDEWEB)

    Gross, R. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2009-06-05

    The Clean Air Act (1970) is the comprehensive federal law that regulates air emissions from stationary and mobile sources. Among other things, this law authorized the Environmental Protection Agency (EPA) to establish National Ambient Air Quality Standards to protect public health and public welfare and to regulate emissions of hazardous air pollutants. In recent years, EPA regulations have forced oil refineries into producing a very low sulfur diesel fuel and incentives for adding up to 5% bio-diesel. These changes to the fuel oil formulation are beneficial to air quality and to energy conservation, but adversely impact heat content, long term storage stability, engine power, and injection system reliability. Diesel engines typically have a high incidence of injector failure resulting from poor diesel fuel quality. Since standby diesel engines do not run continuously it is necessary to implement periodic surveillance's to ensure the quality of diesel fuel is acceptable for reliable operation when a loss of power occurs. The information contained in this document is a compilation of best practices to be used as a guide for maintenance of a reliable diesel fuel system.

  3. Corrective Action Decision Document for Corrective Action Unit 322: Areas 1 and 3 Release Sites and Injection Wells Nevada Test Site, Nevada, Rev. No. 0

    Energy Technology Data Exchange (ETDEWEB)

    Robert Boehlecke

    2004-12-01

    This Corrective Action Decision Document has been prepared for Corrective Action Unit (CAU) 322, Areas 1 and 3 Release Sites and Injection Wells, Nevada Test Site, Nevada, in accordance with the ''Federal Facility Agreement and Consent Order'' (1996). Corrective Action Unit 322 is comprised of the following corrective action sites (CASs): (1) 01-25-01 - AST Release Site; (2) 03-25-03 - Mud Plant and AST Diesel Release; and (3) 03-20-05 - Injection Wells and BOP Shop. The purpose of this Corrective Action Decision Document is to identify and provide the rationale for the recommendation of a corrective action alternative for each CAS within CAU 322. Corrective action investigation activities were performed from April 2004 through September 2004, as set forth in the Corrective Action Investigation Plan. The purposes of the activities as defined during the data quality objectives process were: (1) Determine if contaminants of concern (COCs) are present; (2) If COCs are present, determine their nature and extent; and (3) Provide sufficient information and data to recommend appropriate corrective actions for the CASs. Analytes detected during the corrective action investigation were evaluated against appropriate preliminary action levels to identify contaminants of concern for each corrective action site. Radiological field measurements were compared to unrestricted release criteria. Assessment of the data generated from investigation activities revealed the following: (1) CAS 01-25-01 contains an AST berm contaminated with total petroleum hydrocarbons (TPH) diesel-range organics (DRO). (2) CAS 03-25-03 includes two distinct areas: Area A where no contamination remains from a potential spill associated with an AST, and Area B where TPH-DRO contamination associated with various activities at the mud plant was identified. The Area B contamination was found at various locations and depths. (3) CAS 03-25-03 Area B contains TPH-DRO contamination at various

  4. Mercury Induced Biochemical Alterations As Oxidative Stress In Mugil Cephalus In Short Term Toxicity Test

    OpenAIRE

    J.S.I Rajkumar; Samuel Tennyson

    2013-01-01

    Mugil cephalus juveniles of size 2.5 ±0.6cm were exposed to mercury in short term chronic toxicity test through static renewal bioassay to detect the possible biochemical agent as biomarkers in aquatic pollution and in estuarine contamination as specific. Lipid peroxidation levels, glutathione S -transferase, catalase, reduced glutathione and acetylcholinesterase were studied as biochemical parameters. Increased thio-barbituric acid reactive substances levels were observed under exposur...

  5. Evaluation of penicillin G residues by kidney inhibition swab tests in sow body fluids and tissues following intramuscular injection

    Science.gov (United States)

    In 2011, the USDA-Food Safety and Inspection Service (FSIS) changed the method used for screening swine tissues for antimicrobial residues from the Fast Antimicrobial Screen Test to the Kidney Inhibition Swab (KIS(TM)). Here, we describe the use of KIS(TM) test for the detection of penicillin G res...

  6. Quantum dots as chemiluminescence enhancers tested by sequential injection technique: Comparison of flow and flow-batch conditions

    Energy Technology Data Exchange (ETDEWEB)

    Sklenářová, Hana, E-mail: sklenarova@faf.cuni.cz [Charles University in Prague, Faculty of Pharmacy in Hradec Králové, Department of Analytical Chemistry, Hradec Králové (Czech Republic); Voráčová, Ivona [Institute of Analytical Chemistry of the CAS, v. v. i., Brno (Czech Republic); Chocholouš, Petr; Polášek, Miroslav [Charles University in Prague, Faculty of Pharmacy in Hradec Králové, Department of Analytical Chemistry, Hradec Králové (Czech Republic)

    2017-04-15

    The effect of 0.01–100 µmol L{sup −1} Quantum Dots (QDs) with different emission wavelengths (520–640 nm) and different surface modifications (mercaptopropionic, mercaptoundecanoic, thioglycolic acids and mercaptoethylamine) on permanganate-induced and luminol–hydrogen peroxide chemiluminescence (CL) was studied in detail by a sequential injection technique using a spiral detection flow cell and a flow-batch detection cell operated in flow and stop-flow modes. In permanganate CL system no significant enhancement of the CL signal was observed while for the luminol–hydrogen peroxide CL substantial increase (>100% and >90% with the spiral detection cell in flow and stop-flow modes, respectively) was attained for CdTe QDs. Enhancement exceeding 120% was observed for QDs with emissions at 520, 575 and 603 nm (sizes of 2.8 nm, 3.3 nm and 3.6 nm) using the flow-batch detection cell in the stop-flow mode. Pronounced effect was noted for surface modifications while mercaptoethylamine was the most efficient in CL enhancement compared to mercaptopropionic acid the most commonly applied coating. Significant difference between results obtained in flow and flow-batch conditions based on the entire kinetics of the extremely fast CL reaction was discussed. The increase of the CL signal was always accompanied by reduced lifetime of the CL emission thus application of QDs in flow techniques should be always coupled with the study of the CL lifetime.

  7. Pre-Test CFD for the Design and Execution of the Enhanced Injection and Mixing Project at NASA Langley Research Center

    Science.gov (United States)

    Drozda, Tomasz G.; Axdahl, Erik L.; Cabell, Karen F.

    2014-01-01

    With the increasing costs of physics experiments and simultaneous increase in availability and maturity of computational tools it is not surprising that computational fluid dynamics (CFD) is playing an increasingly important role, not only in post-test investigations, but also in the early stages of experimental planning. This paper describes a CFD-based effort executed in close collaboration between computational fluid dynamicists and experimentalists to develop a virtual experiment during the early planning stages of the Enhanced Injection and Mixing project at NASA Langley Research Center. This projects aims to investigate supersonic combustion ramjet (scramjet) fuel injection and mixing physics, improve the understanding of underlying physical processes, and develop enhancement strategies and functional relationships relevant to flight Mach numbers greater than 8. The purpose of the virtual experiment was to provide flow field data to aid in the design of the experimental apparatus and the in-stream rake probes, to verify the nonintrusive measurements based on NO-PLIF, and to perform pre-test analysis of quantities obtainable from the experiment and CFD. The approach also allowed for the joint team to develop common data processing and analysis tools, and to test research ideas. The virtual experiment consisted of a series of Reynolds-averaged simulations (RAS). These simulations included the facility nozzle, the experimental apparatus with a baseline strut injector, and the test cabin. Pure helium and helium-air mixtures were used to determine the efficacy of different inert gases to model hydrogen injection. The results of the simulations were analyzed by computing mixing efficiency, total pressure recovery, and stream thrust potential. As the experimental effort progresses, the simulation results will be compared with the experimental data to calibrate the modeling constants present in the CFD and validate simulation fidelity. CFD will also be used to

  8. Controlled CO2 injection into a shallow aquifer and leakage detection monitoring practices at the K-COSEM site, Korea

    Science.gov (United States)

    Lee, S. S.; Joun, W.; Ju, Y. J.; Ha, S. W.; Jun, S. C.; Lee, K. K.

    2017-12-01

    Artificial carbon dioxide injection into a shallow aquifer system was performed with two injection types imitating short- and long-term CO2 leakage events into a shallow aquifer. One is pulse type leakage of CO2 (6 hours) under a natural hydraulic gradient (0.02) and the other is long-term continuous injection (30 days) under a forced hydraulic gradient (0.2). Injection and monitoring tests were performed at the K-COSEM site in Eumseong, Korea where a specially designed well field had been installed for artificial CO2 release tests. CO2-infused and tracer gases dissolved groundwater was injected through a well below groundwater table and monitoring were conducted in both saturated and unsaturated zones. Real-time monitoring data on CO2 concentration and hydrochemical parameters, and periodical measurements of several gas tracers (He, Ar, Kr, SF6) were obtained. The pulse type short-term injection test was carried out prior to the long-term injection test. Results of the short-term injection test, under natural hydraulic gradient, showed that CO2 plume migrated along the preferential pathway identified through hydraulic interference tests. On the other hand, results of the long-term injection test indicated the CO2 plume migration path was aligned to the forced hydraulic gradient. Compared to the short-term test, the long-term injection formed detectable CO2 concentration change in unsaturated wellbores. Recovery data of tracer gases made breakthrough curves compatible to numerical simulation results. The monitoring results indicated that detection of CO2 leakage into groundwater was more effectively performed by using a pumping and monitoring method in order to capture by-passing plume. With this concept, an effective real-time monitoring method was proposed. Acknowledgement: Financial support was provided by the "R&D Project on Environmental Management of Geologic CO2storage" from the KEITI (Project number : 2014001810003)

  9. Design and fabrication of a unique electromechanical machine for long-term fatigue testing

    International Nuclear Information System (INIS)

    Boling, K.W.

    1984-12-01

    An electromechanical machine has been designed and fabricated for performing long-term fatigue tests under conditions that simulate those in modern plants. The machine is now commercially available. Its advantages over current electrohydraulic machines are lower initial cost, minimum maintenance requirements, and greater reliability especially when performing long tests. The machine operates in closed-loop fashion by utilizing continuous feedback signals from the specimen extensometer or load cell, it is programmable for testing in strain or load control. The maximum ram rate is 0.056 mm/s (0.134 in./min), maximum ram travel is 102 mm (4 in.) and load capacity is +-44 (+-10 kips). Induction heating controls speciment temperatures to 1000 0 C

  10. Test Particle Simulations of Electron Injection by the Bursty Bulk Flows (BBFs) using High Resolution Lyon-Feddor-Mobarry (LFM) Code

    Science.gov (United States)

    Eshetu, W. W.; Lyon, J.; Wiltberger, M. J.; Hudson, M. K.

    2017-12-01

    Test particle simulations of electron injection by the bursty bulk flows (BBFs) have been done using a test particle tracer code [1], and the output fields of the Lyon-Feddor-Mobarry global magnetohydro- dynamics (MHD) code[2]. The MHD code was run with high resolu- tion (oct resolution), and with specified solar wind conditions so as to reproduce the observed qualitative picture of the BBFs [3]. Test par- ticles were injected so that they interact with earthward propagating BBFs. The result of the simulation shows that electrons are pushed ahead of the BBFs and accelerated into the inner magnetosphere. Once electrons are in the inner magnetosphere they are further energized by drift resonance with the azimuthal electric field. In addition pitch angle scattering of electrons resulting in the violation conservation of the first adiabatic invariant has been observed. The violation of the first adiabatic invariant occurs as electrons cross a weak magnetic field region with a strong gradient of the field perturbed by the BBFs. References 1. Kress, B. T., Hudson,M. K., Looper, M. D. , Albert, J., Lyon, J. G., and Goodrich, C. C. (2007), Global MHD test particle simulations of ¿ 10 MeV radiation belt electrons during storm sudden commencement, J. Geophys. Res., 112, A09215, doi:10.1029/2006JA012218. Lyon,J. G., Fedder, J. A., and Mobarry, C.M., The Lyon- Fedder-Mobarry (LFM) Global MHD Magnetospheric Simulation Code (2004), J. Atm. And Solar-Terrestrial Phys., 66, Issue 15-16, 1333- 1350,doi:10.1016/j.jastp. Wiltberger, Merkin, M., Lyon, J. G., and Ohtani, S. (2015), High-resolution global magnetohydrodynamic simulation of bursty bulk flows, J. Geophys. Res. Space Physics, 120, 45554566, doi:10.1002/2015JA021080.

  11. Feasibility test of the concept of long-term passive cooling system of emergency cooldown tank

    International Nuclear Information System (INIS)

    Kim, Myoung Jun; Moon, Joo Hyung; Bae, Youngmin; Kim, Young In; Lee, Hee Joon

    2015-01-01

    Highlights: • The concept of long-term passive cooling system of emergency cooldown tank (ECT). • Existing natural circulation of steam from ECT and measurement of its condensing flow. • Evaluation of cooling capacity and heat transfer of air-cooled condensing heat exchanger. - Abstract: When a passive cooling system is activated in the accident of a nuclear reactor, the water in the emergency cooldown tank of that system will eventually be fully depleted by evaporation. If, however, the evaporating water could be returned to the tank through an air-cooled condensing heat exchanger mounted on top of the tank, the passive cooling system could provide cooling for an extended period. This feasibility of new concept of long-term passive cooling with an emergency cooldown tank was tested by performing an energy balance test with a scaled-down experimental setup. As a result, it was determined that a naturally circulating steam flow can be used to refill the tank. For an air-cooled heat exchanger, the cooling capacity and air-side natural convective heat transfer coefficient were obtained to be 37% of the heat load and between 9 and 10.2 W/m 2 /K depending on the heat load, respectively. Moreover, it was clearly verified that the water level in the emergency cooldown tank could be maintained over the long-term operation of the passive cooling system

  12. Case study on ground surface deformation induced by CO2 injection into coal seam

    International Nuclear Information System (INIS)

    Li Hong; Tang Chun'an

    2010-01-01

    To monitor a geomechanical response of injecting CO 2 into relatively shallow coal seams, tiltmeters were set as an array to cover the ground surface area surrounding the injection well, and to measure the ground deformation during a well fracturing stimulation and a short-term CO 2 injection test. In this paper, an attempt to establish a quantitative relationship between the in-situ coal swelling and the corresponding ground deformation was made by means of numerical simulation study. (authors)

  13. Patient empowerment in long-term conditions: development and preliminary testing of a new measure

    Science.gov (United States)

    2013-01-01

    Background Patient empowerment is viewed by policy makers and health care practitioners as a mechanism to help patients with long-term conditions better manage their health and achieve better outcomes. However, assessing the role of empowerment is dependent on effective measures of empowerment. Although many measures of empowerment exist, no measure has been developed specifically for patients with long-term conditions in the primary care setting. This study presents preliminary data on the development and validation of such a measure. Methods We conducted two empirical studies. Study one was an interview study to understand empowerment from the perspective of patients living with long-term conditions. Qualitative analysis identified dimensions of empowerment, and the qualitative data were used to generate items relating to these dimensions. Study two was a cross-sectional postal study involving patients with different types of long-term conditions recruited from general practices. The survey was conducted to test and validate our new measure of empowerment. Factor analysis and regression were performed to test scale structure, internal consistency and construct validity. Results Sixteen predominately elderly patients with different types of long-term conditions described empowerment in terms of 5 dimensions (identity, knowledge and understanding, personal control, personal decision-making, and enabling other patients). One hundred and ninety seven survey responses were received from mainly older white females, with relatively low levels of formal education, with the majority retired from paid work. Almost half of the sample reported cardiovascular, joint or diabetes long-term conditions. Factor analysis identified a three factor solution (positive attitude and sense of control, knowledge and confidence in decision making and enabling others), although the structure lacked clarity. A total empowerment score across all items showed acceptable levels of internal

  14. Lesser Neural Pattern Similarity across Repeated Tests Is Associated with Better Long-Term Memory Retention.

    Science.gov (United States)

    Karlsson Wirebring, Linnea; Wiklund-Hörnqvist, Carola; Eriksson, Johan; Andersson, Micael; Jonsson, Bert; Nyberg, Lars

    2015-07-01

    Encoding and retrieval processes enhance long-term memory performance. The efficiency of encoding processes has recently been linked to representational consistency: the reactivation of a representation that gets more specific each time an item is further studied. Here we examined the complementary hypothesis of whether the efficiency of retrieval processes also is linked to representational consistency. Alternatively, recurrent retrieval might foster representational variability--the altering or adding of underlying memory representations. Human participants studied 60 Swahili-Swedish word pairs before being scanned with fMRI the same day and 1 week later. On Day 1, participants were tested three times on each word pair, and on Day 7 each pair was tested once. A BOLD signal change in right superior parietal cortex was associated with subsequent memory on Day 1 and with successful long-term retention on Day 7. A representational similarity analysis in this parietal region revealed that beneficial recurrent retrieval was associated with representational variability, such that the pattern similarity on Day 1 was lower for retrieved words subsequently remembered compared with those subsequently forgotten. This was mirrored by a monotonically decreased BOLD signal change in dorsolateral prefrontal cortex on Day 1 as a function of repeated successful retrieval for words subsequently remembered, but not for words subsequently forgotten. This reduction in prefrontal response could reflect reduced demands on cognitive control. Collectively, the results offer novel insights into why memory retention benefits from repeated retrieval, and they suggest fundamental differences between repeated study and repeated testing. Repeated testing is known to produce superior long-term retention of the to-be-learned material compared with repeated encoding and other learning techniques, much because it fosters repeated memory retrieval. This study demonstrates that repeated memory

  15. Subsurface impact of CO2: Response of carbonate rocks and wellbore cement to supercritical CO2 injection and long-term storage. Geologica Ultraiectina (310)

    NARCIS (Netherlands)

    Liteanu, E.

    2009-01-01

    Capture of CO2 at fossil fuel power station coupled with geological storage in empty oil and gas reservoirs is widely viewed as the most promising option for reducing CO2 emissions to the atmosphere, i.e. for climate change mitigation. Injection of CO2 into such reservoirs will change their chemical

  16. Long- and short-term trends in vessel conditioning of TFTR [Tokamak Fusion Test Reactor

    International Nuclear Information System (INIS)

    LaMarche, P.H.; Dylla, H.F.; Bell, M.G.

    1986-10-01

    We have investigated trends in the conditioning of the Tokamak Fusion Test Reactor (TFTR) vacuum vessel during the May 1984 to April 1985 run period. The initial conditioning of the vessel, consisting of glow discharge cleaning (GDC) and pulse discharge cleaning (PDC) in concert with a 150 0 C vessel bakeout, is necessary to assure plasma operation after atmospheric venting. A long-term conditioning process, ascribed to limiter conditioning, effectively improves operational conditions during the course of the run. Over several thousand high power plasma discharges, the improvement was documented by using standard parameter (fiducial) plasma discharges. Several techniques demonstrated short-term improvements in vessel conditioning during this time period, including: Cr gettering and programming the plasma position relative to the limiter contact area

  17. The retrieval efficiency test of descriptors and free vocabulary terms in INIS on-line search

    International Nuclear Information System (INIS)

    Ebinuma, Yukio; Takahashi, Satoko

    1981-01-01

    The test was done for 1) search topics with appropriate descriptors, 2) search topics with considerably broader descriptors, 3) search topics with no appropriate descriptors. As to (1) and (2) the retrieval efficiency was the same both on descriptor system and on keyword system (descriptors + free terms), and the search formulas were easily constructed. As to (3) the descriptor system ensured the recall ratio but decreased the precision ratio. On the other hand the keyword system made the construction of search formulas easy and resulted in good retrieval efficiency. The search system which is available both for full match method of descriptors and truncation method of keywords is desirable because each method can be selected according to the searcher's strategy and search topics. Free-term system seems unnecessary. (author)

  18. Long-term culture of undifferentiated spermatogonia isolated from immature and adult bovine testes.

    Science.gov (United States)

    Suyatno; Kitamura, Yuka; Ikeda, Shuntaro; Minami, Naojiro; Yamada, Masayasu; Imai, Hiroshi

    2018-03-01

    Undifferentiated spermatogonia eventually differentiate in the testis to produce haploid sperm. Within this cell population, there is a small number of spermatogonial stem cells (SSCs). SSCs are rare cells in the testis, and their cellular characteristics are poorly understood. Establishment of undifferentiated cell line would provide an indispensable tool for studying their biological nature and spermiogenesis/spermatogenesis in vitro. However, there have been few reports on the long-term culture of undifferentiated spermatogonia in species other than rodents. Here, we report the derivation and long-term in vitro culture of undifferentiated spermatogonia cell lines from immature and adult bovine testes. Cell lines from immature testes were maintained in serum-free culture conditions in the presence of glial-cell-line-derived neurotropic factor (GDNF) and bovine leukemia inhibitory factor (bLIF). These cell lines have embryonic stem (ES)-like cell morphology, express pluripotent-stem-cell-specific and germ-cell-specific markers at the protein and mRNA levels, and contributed to the inner cell mass (ICM) of embryos in the blastocyst stage. Meanwhile, cell lines established from adult testes were maintained in low-serum media in the presence of 6-bromoindirubin-3'-oxime (BIO). These cell lines have characteristics resembling those of previously reported male mouse germ cell lines as confirmed by their botryoidally aggregated morphology, as well as the expression of germ-cell-specific markers and pluripotent stem cell markers. These findings could be useful for the development of long-term culture of undifferentiated spermatogonia, which could aid in conservation of species and improvement of livestock production through genome editing technology. © 2018 Wiley Periodicals, Inc.

  19. Long-term durability testing of ceramic cross-flow filter. Final report, September 29, 1987--December 31, 1992

    Energy Technology Data Exchange (ETDEWEB)

    Lippert, T.E.; Smeltzer, E.E.; Alvin, M.A.; Bachovchin, D.M.

    1993-08-01

    Long term durability testing of the cross flow filter is described. Two high temperature, high pressure test facilities were built and operated. The facilities were designed to simulate dirty gas environments typical of Pressurized Fluidized Bed Combustion (PFBC) and coal gasification. Details of the design and operation of the test facilities and filter testing results are described.

  20. Teduglutide Injection

    Science.gov (United States)

    ... who need additional nutrition or fluids from intravenous (IV) therapy. Teduglutide injection is in a class of medications ... of the ingredients.tell your doctor and pharmacist what other prescription and nonprescription medications, vitamins, nutritional supplements, and herbal products you are taking ...

  1. Dexrazoxane Injection

    Science.gov (United States)

    ... are used to treat or prevent certain side effects that may be caused by chemotherapy medications. Dexrazoxane injection (Zinecard) is used to prevent or decrease heart damage caused by doxorubicin in women who are taking the medication to treat breast cancer that has spread to other parts of the ...

  2. Triptorelin Injection

    Science.gov (United States)

    ... puberty too soon, resulting in faster than normal bone growth and development of sexual characteristics) in children 2 years and older. Triptorelin injection is in a class of medications called gonadotropin-releasing hormone (GnRH) agonists. It works by decreasing the amount ...

  3. Extension of Surveillance Test Interval of Safety Injection Pump for APR-1400 Reactors to Improve Reliability and Availability of the Pump

    Energy Technology Data Exchange (ETDEWEB)

    Osama, A. Rezk; Jung, J. C.; Lee, Yong-Kwan [KEPCO International Nuclear Graduate School, Ulsan (Korea, Republic of)

    2015-10-15

    The safety features function to localize, control, mitigate, and terminate such incidents and to hold exposure levels below applicable limits. The safety injection system is comprised of four independent mechanical trains without any tie line among the injection paths and two electrical divisions. Each train has one active Safety Injection Pump (SIP) and one passive Safety Injection Tank (SIT) equipped with a Fluidic Device (FD), each train provides 50% of the minimum injection flow rate for breaks larger than the size of a direct vessel injection line. For breaks equal to or smaller than the size of a direct vessel injection line, each train has 100% of the required capacity. The low pressure injection pumps with common header installed in the conventional design are eliminated, and the functions for safety injection and shutdown cooling are separated. The arrangement of safety injection system for APR-1400 as shown in figure (1). The results obtained in this work show that STI extensions for the SIS feasible without any unacceptable increase in the plant total risk, STI extensions are acceptable for safety injection system to provide plant operational flexibility in the performance of both corrective and preventive maintenance for the safety injection system.

  4. A ductility exhaustion evaluation of some long term creep/fatigue tests on austenitic steel

    International Nuclear Information System (INIS)

    Wood, D.S.; Wynn, J.; Austin, C.; Green, J.G.

    1988-01-01

    A limited number of long term creep/fatigue tests performed on two batches of Type 316 steel and one batch of associated 17Cr8Ni2Mo weld metal are reported. Test durations range from 5000 to 32,000 h and temperatures from 550 to 625 0 C. Subsequent metallographic examination shows the failures to be wholly or predominantly intergranular. The results are analysed using a ductility exhaustion approach and it is shown that the endurances obtained are within a factor of two of predicted values. The results confirm that the design approach to creep/fatigue currently being developed in the U.K. and based on ductility exhaustion is likely to be satisfactory. (author)

  5. Double Crowding-Out Effects of Means-Tested Public Provision for Long-Term Care

    Directory of Open Access Journals (Sweden)

    Christophe Courbage

    2015-02-01

    Full Text Available Publicly provided long-term care (LTC insurance with means-tested benefits is suspected to crowd out either private saving or informal care. This contribution predicts crowding-out effects for both private saving and informal care for policy measures designed to relieve the public purse from LTC expenditure such as more stringent means testing and increased taxation of inheritance. These effects result from the interaction of a parent who decides on the amount of saving in retirement and a caregiver who decides on the effort devoted to informal care which lowers the probability of admission to a nursing home. Double crowding-out effects are also found to be the consequence of exogenous influences, notably a higher opportunity cost of caregiving.

  6. Long-term retention of a divided attention psycho-motor test combining choice reaction test and postural balance test: A preliminary study.

    Science.gov (United States)

    Rossi, R; Pascolo, P B

    2015-09-01

    Driving in degraded psychophysical conditions, such as under the influence of alcohol or drugs but also in a state of fatigue or drowsiness, is a growing problem. The current roadside tests used for detecting drugs from drivers suffer various limitations, while impairment is subjective and does not necessarily correlate with drug metabolite concentration found in body fluids. This work is a validation step towards the study of feasibility of a novel test conceived to assess psychophysical conditions of individuals performing at-risk activities. Motor gestures, long-term retention and learning phase related to the protocol are analysed in unimpaired subjects. The protocol is a divided attention test, which combines a critical tracking test achieved with postural movements and a visual choice reaction test. Ten healthy subjects participated in a first set of trials and in a second set after about six months. Each session required the carrying out of the test for ten times in order to investigate learning effect and performance over repetitions. In the first set the subjects showed a learning trend up to the third trial, whilst in the second set of trials they showed motor retention. Nevertheless, the overall performance did not significantly improve. Gestures are probably retained due to the type of tasks and the way in which the instructions are conveyed to the subjects. Moreover, motor retention after a short training suggests that the protocol is easy to learn and understand. Implications for roadside test usage and comparison with current tests are also discussed. Copyright © 2015 Elsevier Ltd. All rights reserved.

  7. Long term test of buffer material. Final Report on the pilot parcels

    International Nuclear Information System (INIS)

    Karnland, Ola; Sanden, Torbjoern; Johannesson, Lars-Erik; Eriksen, Trygve E; Jansson, Mats; Wold, Susanna; Pedersen, Karsten; Motamedi, Mehrdad; Rosborg, Bo

    2000-12-01

    The 'Long Term Test of Buffer Material' (LOT) series at the Aespoe HRL aims at checking models and hypotheses for a bentonite buffer material under conditions similar to those in a KBS3 repository. The test series comprises seven test parcels, which are exposed to repository conditions for 1, 5 and 20 years. This report concerns the two completed pilot tests (1-year tests) with respect to construction, field data and laboratory results. Four research groups were engaged in this part of the project working on physical properties - mineralogy, cation diffusion, bacteria and copper corrosion, respectively. The experimental layout was to place parcels containing heater, central copper tube, pre-compacted bentonite blocks and instruments in vertical boreholes in crystalline rock. The heaters were used for simulating the decay power from spent nuclear fuel at standard KBS3 conditions (S1 parcel, 90 deg C) and to give adverse conditions (A1 parcel, 130 deg C). The latter was used in order to accelerate possible processes. Temperature, total pressure, water pressure and water content were measured during the heating period. The two pilot tests were terminated after approximately 12 months of heating, and the parcels were extracted by overlapping core drilling outside the original borehole. The entire 4.5 m long S1-parcel with approximately 20 cm rock cover was successfully lifted in one piece from the rock, whereas the central part of the A1 parcel was lost during drilling. The upper and lower parts were however retrieved. Reference and exposed bentonite material were analysed with respect to physical properties (triaxial, beam and oedometer tests), and to mineralogical properties (XRD, CEC, ICP-AES and SEM analyses) according to a defined test program. Some precipitation, mainly gypsum, was found in the warmest part of the parcels, and the only unpredicted change was minor uptake of Cu into the clay matrix. An overarching conclusion is that no degrading processes, with

  8. Long term test of buffer material. Final Report on the pilot parcels

    Energy Technology Data Exchange (ETDEWEB)

    Karnland, Ola; Sanden, Torbjoern; Johannesson, Lars-Erik [Clay Technology AB, Lund (Sweden); Eriksen, Trygve E; Jansson, Mats; Wold, Susanna [Royal Inst. of Tech., Stockholm (Sweden); Pedersen, Karsten; Motamedi, Mehrdad [Goeteborg Univ. (Sweden); Rosborg, Bo [Studsvik Material AB, Nykoeping (Sweden)

    2000-12-01

    The 'Long Term Test of Buffer Material' (LOT) series at the Aespoe HRL aims at checking models and hypotheses for a bentonite buffer material under conditions similar to those in a KBS3 repository. The test series comprises seven test parcels, which are exposed to repository conditions for 1, 5 and 20 years. This report concerns the two completed pilot tests (1-year tests) with respect to construction, field data and laboratory results. Four research groups were engaged in this part of the project working on physical properties - mineralogy, cation diffusion, bacteria and copper corrosion, respectively. The experimental layout was to place parcels containing heater, central copper tube, pre-compacted bentonite blocks and instruments in vertical boreholes in crystalline rock. The heaters were used for simulating the decay power from spent nuclear fuel at standard KBS3 conditions (S1 parcel, 90 deg C) and to give adverse conditions (A1 parcel, 130 deg C). The latter was used in order to accelerate possible processes. Temperature, total pressure, water pressure and water content were measured during the heating period. The two pilot tests were terminated after approximately 12 months of heating, and the parcels were extracted by overlapping core drilling outside the original borehole. The entire 4.5 m long S1-parcel with approximately 20 cm rock cover was successfully lifted in one piece from the rock, whereas the central part of the A1 parcel was lost during drilling. The upper and lower parts were however retrieved. Reference and exposed bentonite material were analysed with respect to physical properties (triaxial, beam and oedometer tests), and to mineralogical properties (XRD, CEC, ICP-AES and SEM analyses) according to a defined test program. Some precipitation, mainly gypsum, was found in the warmest part of the parcels, and the only unpredicted change was minor uptake of Cu into the clay matrix. An overarching conclusion is that no degrading

  9. Mortality and causes of death among people who inject amphetamine: A long-term follow-up cohort study from a needle exchange program in Sweden.

    Science.gov (United States)

    Åhman, Ada; Jerkeman, Anna; Blomé, Marianne Alanko; Björkman, Per; Håkansson, Anders

    2018-07-01

    Abuse of amphetamines is a worldwide problem with around 34 million users, and amphetamine is commonly used by people who inject drugs (PWID). Despite this, there is relatively little research on mortality and cause of death among people who use amphetamines primarily. The present study aimed to examine mortality and causes of death among people who inject amphetamine, and compare these results to the general population. This retrospective cohort study was based on data from The Malmö Needle Exchange Program in Sweden (MNEP) and on data from The Swedish National Cause of Death Register. Participants in the MNEP, between 1987 and 2011, with registered national identity number and amphetamine as their primary drug of injection use, were included in the study. Standardized mortality ratios (SMR) was calculated for overall mortality and categories of causes of death. 2019 individuals were included (mean follow-up-time 13.7 years [range 0.02-24.2 years], a total of 27,698 person-years). Of the 448 deceased, 428 had a registered cause of death. The most common causes of death were external causes (n = 162, 38%), followed by diseases of the circulatory system (n = 67, 16%). SMR were significantly elevated (8.3, 95% CI [7.5-9.1]) for the entire study population, and for every category of causes of death respectively. People injecting amphetamine as a primary drug were found to have significantly elevated mortality compared with the general population, with high rates of both external and somatic causes of death. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.

  10. UV-visible digital imaging of split injection in a Gasoline Direct Injection engine

    Directory of Open Access Journals (Sweden)

    Merola Simona Silvia

    2015-01-01

    Full Text Available Ever tighter limits on pollutant emissions and the need to improve energy conversion efficiency have made the application of gasoline direct injection (GDI feasible for a much wider scale of spark ignition engines. Changing the way fuel is delivered to the engine has thus provided increased flexibility but also challenges, such as higher particulate emissions. Therefore, alternative injection control strategies need to be investigated in order to obtain optimum performance and reduced environmental impact. In this study, experiments were carried out on a single-cylinder GDI optical engine fuelled with commercial gasoline in lean-burn conditions. The single-cylinder was equipped with the head of a commercial turbocharged engine with similar geometrical specifications (bore, stroke, compression ratio and wall guided fuel injection. Optical accessibility was ensured through a conventional elongated hollow Bowditch piston and an optical crown, accommodating a fused-silica window. Experimental tests were performed at fixed engine speed and injection pressure, whereas the injection timing and the number of injections were adjusted to investigate their influence on combustion and emissions. UV-visible digital imaging was applied in order to follow the combustion process, from ignition to the late combustion phase. All the optical data were correlated with thermodynamic analysis and measurements of exhaust emissions. Split injection strategies (i.e. two injections per cycle with respect to single injection increased combustion efficiency and stability thanks to an improvement of fuel air mixing. As a consequence, significant reduction in soot formation and exhaust emission with acceptable penalty in terms of HC and NOx were measured.

  11. New results on long term aging tests for rad-waste container alloy selection

    International Nuclear Information System (INIS)

    Alves, H.; Wahl, V.; Ibas, O.; Stenner, F.

    2004-01-01

    The current design of containers for high level nuclear waste proceeds on using an outer barrier of corrosion resistant Ni-based super alloy. The current alloy of choice is alloy 22 (UNS N06022). It is a quaternary Ni-Cr- Mo-W alloy system. The new but well established alloy 59 (UNS N06059) is an excellent equal or even a superior alternative to alloy 22 for the 10,000 years reliability being sought. Alloy 59 is a pure ternary alloy in the Ni-Cr-Mo alloy system. Objective of this paper is to present data comparing these two alloys. Therefore the behaviour of alloy 59 and alloy 22 was characterised after aging in air for 10,000 h and 20,000 h at different temperatures (200, 300 and 427 deg. C). Since the performance of weldments is of great concern, both welded and unwelded specimens were studied. Mechanical properties of the air aged alloys were measured at room temperature by tensile and notch impact-bending test. Thermal stability and aqueous corrosion are considered to be the key issues in the long-term performance of container materials proposed for the geological disposal of high level nuclear waste. The long-term thermal stability and corrosion resistance of the alloy 59 compared to alloy 22 is discussed. Corrosion resistance was evaluated in ASTM G28 A and 'green death' solution laboratory tests; hereby corrosion rates and depth of attack were determined. Metallo-graphical studies were performed in mill annealed and air aged conditions. The results of the aging tests at 10,000 h and 20,000 h show that alloy 59 is an equal or better candidate material due to its superior localised corrosion resistance behaviour (pitting and crevice corrosion resistance) and better thermal stability needed especially in multi-pass welding of thick sections. Therefore alloy 59 seems to be the most promising alternative to alloy 22. (authors)

  12. New results on long term aging tests for rad-waste container alloy selection

    Energy Technology Data Exchange (ETDEWEB)

    Alves, H.; Wahl, V.; Ibas, O.; Stenner, F. [ThyssenKrupp VDM GmbH, Altena (Germany)

    2004-07-01

    The current design of containers for high level nuclear waste proceeds on using an outer barrier of corrosion resistant Ni-based super alloy. The current alloy of choice is alloy 22 (UNS N06022). It is a quaternary Ni-Cr- Mo-W alloy system. The new but well established alloy 59 (UNS N06059) is an excellent equal or even a superior alternative to alloy 22 for the 10,000 years reliability being sought. Alloy 59 is a pure ternary alloy in the Ni-Cr-Mo alloy system. Objective of this paper is to present data comparing these two alloys. Therefore the behaviour of alloy 59 and alloy 22 was characterised after aging in air for 10,000 h and 20,000 h at different temperatures (200, 300 and 427 deg. C). Since the performance of weldments is of great concern, both welded and unwelded specimens were studied. Mechanical properties of the air aged alloys were measured at room temperature by tensile and notch impact-bending test. Thermal stability and aqueous corrosion are considered to be the key issues in the long-term performance of container materials proposed for the geological disposal of high level nuclear waste. The long-term thermal stability and corrosion resistance of the alloy 59 compared to alloy 22 is discussed. Corrosion resistance was evaluated in ASTM G28 A and 'green death' solution laboratory tests; hereby corrosion rates and depth of attack were determined. Metallo-graphical studies were performed in mill annealed and air aged conditions. The results of the aging tests at 10,000 h and 20,000 h show that alloy 59 is an equal or better candidate material due to its superior localised corrosion resistance behaviour (pitting and crevice corrosion resistance) and better thermal stability needed especially in multi-pass welding of thick sections. Therefore alloy 59 seems to be the most promising alternative to alloy 22. (authors)

  13. Uptake of genetic testing and long-term tumor surveillance in von Hippel-Lindau disease

    Directory of Open Access Journals (Sweden)

    Chávez Mireya

    2010-01-01

    Full Text Available Abstract Background von Hippel-Lindau (VHL disease is a hereditary cancer syndrome caused by germline mutations in the VHL gene. Patients have significant morbidity and mortality secondary to vascular tumors. Disease management is centered on tumor surveillance that allows early detection and treatment. Presymptomatic genetic testing is therefore recommended, including in at-risk children. Methods We tested 17 families (n = 109 individuals for VHL mutations including 43 children under the age of 18. Personalized genetic counseling was provided pre and post-test and the individuals undergoing presymptomatic testing filled out questionnaires gathering socio-demographic, psychological and psychiatric data. Mutation analysis was performed by direct sequencing of the VHL gene. Mutation-carriers were screened for VHL disease-related tumors and were offered follow-up annual examinations. Results Mutations were identified in 36 patients, 17 of whom were asymptomatic. In the initial screening, we identified at least one tumor in five of 17 previously asymptomatic individuals. At the end of five years, only 38.9% of the mutation-carriers continued participating in our tumor surveillance program. During this time, 14 mutation carriers developed a total of 32 new tumors, three of whom died of complications. Gender, education, income, marital status and religiosity were not found to be associated with adherence to the surveillance protocol. Follow-up adherence was also independent of pre-test depression, severity of disease, or number of affected family members. The only statistically significant predictor of adherence was being symptomatic at the time of testing (OR = 5; 95% CI 1.2 - 20.3; p = 0.02. Pre-test anxiety was more commonly observed in patients that discontinued follow-up (64.7% vs. 35.3%; p = 0.01. Conclusions The high initial uptake rate of genetic testing for VHL disease, including in minors, allowed the discontinuation of unnecessary screening

  14. Long-term storage life of light source modules by temperature cycling accelerated life test

    International Nuclear Information System (INIS)

    Sun Ningning; Tan Manqing; Li Ping; Jiao Jian; Guo Xiaofeng; Guo Wentao

    2014-01-01

    Light source modules are the most crucial and fragile devices that affect the life and reliability of the interferometric fiber optic gyroscope (IFOG). While the light emitting chips were stable in most cases, the module packaging proved to be less satisfactory. In long-term storage or the working environment, the ambient temperature changes constantly and thus the packaging and coupling performance of light source modules are more likely to degrade slowly due to different materials with different coefficients of thermal expansion in the bonding interface. A constant temperature accelerated life test cannot evaluate the impact of temperature variation on the performance of a module package, so the temperature cycling accelerated life test was studied. The main failure mechanism affecting light source modules is package failure due to solder fatigue failure including a fiber coupling shift, loss of cooling efficiency and thermal resistor degradation, so the Norris-Landzberg model was used to model solder fatigue life and determine the activation energy related to solder fatigue failure mechanism. By analyzing the test data, activation energy was determined and then the mean life of light source modules in different storage environments with a continuously changing temperature was simulated, which has provided direct reference data for the storage life prediction of IFOG. (semiconductor devices)

  15. Performance norms for a rhesus monkey neuropsychological testing battery: acquisition and long-term performance.

    Science.gov (United States)

    Weed, M R; Taffe, M A; Polis, I; Roberts, A C; Robbins, T W; Koob, G F; Bloom, F E; Gold, L H

    1999-10-25

    A computerized behavioral battery based upon human neuropsychological tests (CANTAB, CeNeS, Cambridge, UK) has been developed to assess cognitive behaviors of rhesus monkeys. Monkeys reliably performed multiple tasks, providing long-term assessment of changes in a number of behaviors for a given animal. The overall goal of the test battery is to characterize changes in cognitive behaviors following central nervous system (CNS) manipulations. The battery addresses memory (delayed non-matching to sample, DNMS; spatial working memory, using a self-ordered spatial search task, SOSS), attention (intra-/extra-dimensional shift, ID/ED), motivation (progressive-ratio, PR), reaction time (RT) and motor coordination (bimanual task). As with human neuropsychological batteries, different tasks are thought to involve different neural substrates, and therefore performance profiles should assess function in particular brain regions. Monkeys were tested in transport cages, and responding on a touch sensitive computer monitor was maintained by food reinforcement. Parametric manipulations of several tasks demonstrated the sensitivity of performance to increases in task difficulty. Furthermore, the factors influencing difficulty for rhesus monkeys were the same as those shown to affect human performance. Data from this study represent performance of a population of healthy normal monkeys that will be used for comparison in subsequent studies of performance following CNS manipulations such as infection with simian immunodeficiency virus (NeuroAIDS) or drug administration.

  16. Scaleup tests and supporting research for the development of duct injection technology: Topical report No. 3, Task 3.2: Scale-up testing; Topical report No. 4, Task 3.3: Advanced configurations; Topical report No. 5, Task 3.4: Process controls; Topical report No. 6, Task 3.5: Failure modes; Task 3.6: Waste characterization, Duct Injection Test Facility, Muskingum River Power Plant, Beverly, Ohio

    Energy Technology Data Exchange (ETDEWEB)

    Felix, L.G.; Gooch, J.P.; Merritt, R.L. [Southern Research Inst., Birmingham, AL (United States); Klett, M.G.; Demian, A.G.; Hunt, J.E. [Gilbert/Commonwealth, Inc., Reading, PA (United States)

    1992-08-01

    This document is the third interim report on tests that were conducted at the Duct Injection Test Facility (DITF) operated for the Department of Energy at Unit 5 of the Ohio Power Company`s Muskingum River station in Beverly, Ohio. At the DITF dry calcium hydroxide (Ca(OH)2), an aqueous slurry of Ca(OH){sub 2} (prepared by slaking quicklime), or a mixture of one of these sorbents with waste ash from earlier tests was injected into a slipstream of flue gas from the Unit 5 boiler to achieve partial removal of SO{sub 2} in the flue gas. Up to 50,000 acfm of flue gas was taken from the inlet to the Unit 5 electrostatic precipitator (ESP) for these tests. Water was injected separately with the dry sorbent or as part of the slurry to cool the flue gas and increase the water vapor content of the flue gas. The addition of water, either as a separate spray or in the slurry makes the reaction between the sorbent and the SO{sub 2} more complete; the presumption is that water is effective in the liquid state when it can physically wet the sorbent particles, and not especially effective in the vapor state. Higher values of calcium utilization were obtained with slurry injection than with dry sorbent injection and humidification. Slurries made from reagent slaked lime, mixtures of reagent slaked lime and recycle ash, and from recycle ash alone were injected through the same nozzles used for humidification. The focus of most of these tests was on the constant addition of recycle ash to reduce the amount of slaked lime required for SO{sub 2} removal (for best economics). Testing was continued until the amount of Ca(OH){sub 2} in the recycle ash equaled that predicted for equilibrium Two test cases were evaluated: a low Ca/S ratio (1.0 reagent, 44{degrees}/F approach) for 50% SO{sub 2} removal and a high Ca/S ratio (1.7 reagent, 24{degrees}F approach) for 88% SO{sub 2} removal.

  17. Scaleup tests and supporting research for the development of duct injection technology: Topical report No. 3, Task 3. 2: Scale-up testing; Topical report No. 4, Task 3. 3: Advanced configurations; Topical report No. 5, Task 3. 4: Process controls; Topical report No. 6, Task 3. 5: Failure modes; Task 3. 6: Waste characterization, Duct Injection Test Facility, Muskingum River Power Plant, Beverly, Ohio

    Energy Technology Data Exchange (ETDEWEB)

    Felix, L.G.; Gooch, J.P.; Merritt, R.L. (Southern Research Inst., Birmingham, AL (United States)); Klett, M.G.; Demian, A.G.; Hunt, J.E. (Gilbert/Commonwealth, Inc., Reading, PA (United States))

    1992-08-01

    This document is the third interim report on tests that were conducted at the Duct Injection Test Facility (DITF) operated for the Department of Energy at Unit 5 of the Ohio Power Company's Muskingum River station in Beverly, Ohio. At the DITF dry calcium hydroxide (Ca(OH)2), an aqueous slurry of Ca(OH)[sub 2] (prepared by slaking quicklime), or a mixture of one of these sorbents with waste ash from earlier tests was injected into a slipstream of flue gas from the Unit 5 boiler to achieve partial removal of SO[sub 2] in the flue gas. Up to 50,000 acfm of flue gas was taken from the inlet to the Unit 5 electrostatic precipitator (ESP) for these tests. Water was injected separately with the dry sorbent or as part of the slurry to cool the flue gas and increase the water vapor content of the flue gas. The addition of water, either as a separate spray or in the slurry makes the reaction between the sorbent and the SO[sub 2] more complete; the presumption is that water is effective in the liquid state when it can physically wet the sorbent particles, and not especially effective in the vapor state. Higher values of calcium utilization were obtained with slurry injection than with dry sorbent injection and humidification. Slurries made from reagent slaked lime, mixtures of reagent slaked lime and recycle ash, and from recycle ash alone were injected through the same nozzles used for humidification. The focus of most of these tests was on the constant addition of recycle ash to reduce the amount of slaked lime required for SO[sub 2] removal (for best economics). Testing was continued until the amount of Ca(OH)[sub 2] in the recycle ash equaled that predicted for equilibrium Two test cases were evaluated: a low Ca/S ratio (1.0 reagent, 44[degrees]/F approach) for 50% SO[sub 2] removal and a high Ca/S ratio (1.7 reagent, 24[degrees]F approach) for 88% SO[sub 2] removal.

  18. Corrective Action Decision Document for Corrective Action Unit 322: Areas 1 and 3 Release Sites and Injection Wells Nevada Test Site, Nevada, Revision 0 with ROTC 1

    International Nuclear Information System (INIS)

    Boehlecke, Robert

    2004-01-01

    This Corrective Action Decision Document has been prepared for Corrective Action Unit (CAU) 322, Areas 1 and 3 Release Sites and Injection Wells, Nevada Test Site, Nevada, in accordance with the ''Federal Facility Agreement and Consent Order'' (1996). Corrective Action Unit 322 is comprised of the following corrective action sites (CASs): (1) 01-25-01 - AST Release Site; (2) 03-25-03 - Mud Plant and AST Diesel Release; and (3) 03-20-05 - Injection Wells and BOP Shop. The purpose of this Corrective Action Decision Document is to identify and provide the rationale for the recommendation of a corrective action alternative for each CAS within CAU 322. Corrective action investigation activities were performed from April 2004 through September 2004, as set forth in the Corrective Action Investigation Plan. The purposes of the activities as defined during the data quality objectives process were: (1) Determine if contaminants of concern (COCs) are present; (2) If COCs are present, determine their nature and extent; and (3) Provide sufficient information and data to recommend appropriate corrective actions for the CASs. Analytes detected during the corrective action investigation were evaluated against appropriate preliminary action levels to identify contaminants of concern for each corrective action site. Radiological field measurements were compared to unrestricted release criteria. Assessment of the data generated from investigation activities revealed the following: (1) CAS 01-25-01 contains an AST berm contaminated with total petroleum hydrocarbons (TPH) diesel-range organics (DRO). (2) CAS 03-25-03 includes two distinct areas: Area A where no contamination remains from a potential spill associated with an AST, and Area B where TPH-DRO contamination associated with various activities at the mud plant was identified. The Area B contamination was found at various locations and depths. (3) CAS 03-25-03 Area B contains TPH-DRO contamination at various locations and

  19. Corrective Action Decision Document for Corrective Action Unit 322: Areas 1 and 3 Release Sites and Injection Wells Nevada Test Site, Nevada, Revision 0 with ROTC 1

    Energy Technology Data Exchange (ETDEWEB)

    Boehlecke, Robert

    2004-12-01

    This Corrective Action Decision Document has been prepared for Corrective Action Unit (CAU) 322, Areas 1 and 3 Release Sites and Injection Wells, Nevada Test Site, Nevada, in accordance with the ''Federal Facility Agreement and Consent Order'' (1996). Corrective Action Unit 322 is comprised of the following corrective action sites (CASs): (1) 01-25-01 - AST Release Site; (2) 03-25-03 - Mud Plant and AST Diesel Release; and (3) 03-20-05 - Injection Wells and BOP Shop. The purpose of this Corrective Action Decision Document is to identify and provide the rationale for the recommendation of a corrective action alternative for each CAS within CAU 322. Corrective action investigation activities were performed from April 2004 through September 2004, as set forth in the Corrective Action Investigation Plan. The purposes of the activities as defined during the data quality objectives process were: (1) Determine if contaminants of concern (COCs) are present; (2) If COCs are present, determine their nature and extent; and (3) Provide sufficient information and data to recommend appropriate corrective actions for the CASs. Analytes detected during the corrective action investigation were evaluated against appropriate preliminary action levels to identify contaminants of concern for each corrective action site. Radiological field measurements were compared to unrestricted release criteria. Assessment of the data generated from investigation activities revealed the following: (1) CAS 01-25-01 contains an AST berm contaminated with total petroleum hydrocarbons (TPH) diesel-range organics (DRO). (2) CAS 03-25-03 includes two distinct areas: Area A where no contamination remains from a potential spill associated with an AST, and Area B where TPH-DRO contamination associated with various activities at the mud plant was identified. The Area B contamination was found at various locations and depths. (3) CAS 03-25-03 Area B contains TPH-DRO contamination at various

  20. Determination of the hydrogen source term during the reflooding of an overheated core: Calculation results of the integral reflood test QUENCH-03 with PWR-type bundle

    International Nuclear Information System (INIS)

    Chikhi, Nourdine; Nguyen, Nam Giang; Fleurot, Joelle

    2012-01-01

    Highlights: ► Calculation of QUENCH-03 experiment with ASTEC/CATHARE. ► Validation of reflooding model in severe accidents conditions. ► Demonstration of a minimum flow rate for a successful reflood by using a system code. ► Effect of injection flow rate on hydrogen production. ► Effect of initial core temperature on hydrogen production. - Abstract: During a severe accident, one of the main accident management procedure consists of injecting water in the reactor core by means of various safety injection devices. Nevertheless, the success of a core reflood is not guaranteed because of possible negative effects: temperature escalation, enhanced hydrogen production, enhanced release of fission products, core degradation due to thermal shock, shattering, debris and melt formation. The QUENCH-03 experiment was carried out to investigate the behavior on reflooding at high temperature of LWR fuel rods with little oxidation. Posttest calculations with the ASTEC-CATHARE V2 code were made for code assessment and validation of the new reflooding model. This thermal–hydraulic model is used to detect the quench front position and to calculate the heat transfer between fuel and fluid in the transition boiling region. Comparisons between the calculational and experimental results are presented. Emphasis has been placed on clad temperature, hydrogen production and melt relocation. The effects of core state damage (initial temperature at reflooding onset) and the reflood mass flow rate on the hydrogen source term were investigated using the QUENCH-03 test as a base case. Calculations were made by varying both parameters in the input data deck. The results demonstrate (and confirm) the existence of a minimum flow rate for a successful reflood.

  1. Microbial characterization for the Source-Term Waste Test Program (STTP) at Los Alamos

    International Nuclear Information System (INIS)

    Leonard, P.A.; Strietelmeier, B.A.; Pansoy-Hjelvik, M.E.; Villarreal, R.

    1999-01-01

    The effects of microbial activity on the performance of the proposed underground nuclear waste repository, the Waste Isolation Pilot Plant (WIPP) at Carlsbad, New Mexico are being studied at Los Alamos National Laboratory (LANL) as part of an ex situ large-scale experiment. Actual actinide-containing waste is being used to predict the effect of potential brine inundation in the repository in the distant future. The study conditions are meant to simulate what might exist should the underground repository be flooded hundreds of years after closure as a result of inadvertent drilling into brine pockets below the repository. The Department of Energy (DOE) selected LANL to conduct the Actinide Source-Term Waste Test Program (STTP) to confirm the predictive capability of computer models being developed at Sandia National Laboratory

  2. Microbial characterization for the Source-Term Waste Test Program (STTP) at Los Alamos

    Energy Technology Data Exchange (ETDEWEB)

    Leonard, P.A.; Strietelmeier, B.A.; Pansoy-Hjelvik, M.E.; Villarreal, R.

    1999-04-01

    The effects of microbial activity on the performance of the proposed underground nuclear waste repository, the Waste Isolation Pilot Plant (WIPP) at Carlsbad, New Mexico are being studied at Los Alamos National Laboratory (LANL) as part of an ex situ large-scale experiment. Actual actinide-containing waste is being used to predict the effect of potential brine inundation in the repository in the distant future. The study conditions are meant to simulate what might exist should the underground repository be flooded hundreds of years after closure as a result of inadvertent drilling into brine pockets below the repository. The Department of Energy (DOE) selected LANL to conduct the Actinide Source-Term Waste Test Program (STTP) to confirm the predictive capability of computer models being developed at Sandia National Laboratory.

  3. Long-Term Degradation Testing of High-Temperature Electrolytic Cells

    Energy Technology Data Exchange (ETDEWEB)

    C.M. Stoots; J.E. O' Brien; J.S. Herring; G.K. Housley; D.G. Milobar; M.S. Sohal

    2009-08-01

    The Idaho National Laboratory (INL) has been researching the application of solid-oxide electrolysis cell for large-scale hydrogen production from steam over a temperature range of 800 to 900ºC. The INL has been testing various solid oxide cell designs to characterize their electrolytic performance operating in the electrolysis mode for hydrogen production. Some results presented in this report were obtained from cells, with an active area of 16 cm2 per cell. The electrolysis cells are electrode-supported, with ~10 µm thick yttria-stabilized zirconia (YSZ) electrolytes, ~1400 µm thick nickel-YSZ steam-hydrogen electrodes, and manganite (LSM) air-oxygen electrodes. The experiments were performed over a range of steam inlet mole fractions (0.1 to 0.6), gas flow rates, and current densities (0 to 0.6 A/cm2). Steam consumption rates associated with electrolysis were measured directly using inlet and outlet dewpoint instrumentation. On a molar basis, the steam consumption rate is equal to the hydrogen production rate. Cell performance was evaluated by performing DC potential sweeps at 800, 850, and 900°C. The voltage-current characteristics are presented, along with values of area-specific resistance as a function of current density. Long-term cell performance is also assessed to evaluate cell degradation. Details of the custom single-cell test apparatus developed for these experiments are also presented. NASA, in conjunction with the University of Toledo, has developed a new cell concept with the goals of reduced weight and high power density. This report presents results of the INL's testing of this new solid oxide cell design as an electrolyzer. Gas composition, operating voltage, and other parameters were varied during testing. Results to date show the NASA cell to be a promising design for both high power-to-weight fuel cell and electrolyzer applications.

  4. Long-Term Degradation Testing of High-Temperature Electrolytic Cells

    International Nuclear Information System (INIS)

    Stoots, C.M.; O'Brien, J.E.; Herring, J.S.; Housley, G.K.; Milobar, D.G.; Sohal, M.S.

    2009-01-01

    The Idaho National Laboratory (INL) has been researching the application of solid-oxide electrolysis cell for large-scale hydrogen production from steam over a temperature range of 800 to 900 C. The INL has been testing various solid oxide cell designs to characterize their electrolytic performance operating in the electrolysis mode for hydrogen production. Some results presented in this report were obtained from cells, with an active area of 16 cm2 per cell. The electrolysis cells are electrode-supported, with ∼10 ∼m thick yttria-stabilized zirconia (YSZ) electrolytes, ∼1400 (micro)m thick nickel-YSZ steam-hydrogen electrodes, and manganite (LSM) air-oxygen electrodes. The experiments were performed over a range of steam inlet mole fractions (0.1 to 0.6), gas flow rates, and current densities (0 to 0.6 A/cm2). Steam consumption rates associated with electrolysis were measured directly using inlet and outlet dewpoint instrumentation. On a molar basis, the steam consumption rate is equal to the hydrogen production rate. Cell performance was evaluated by performing DC potential sweeps at 800, 850, and 900 C. The voltage-current characteristics are presented, along with values of area-specific resistance as a function of current density. Long-term cell performance is also assessed to evaluate cell degradation. Details of the custom single-cell test apparatus developed for these experiments are also presented. NASA, in conjunction with the University of Toledo, has developed a new cell concept with the goals of reduced weight and high power density. This report presents results of the INL's testing of this new solid oxide cell design as an electrolyzer. Gas composition, operating voltage, and other parameters were varied during testing. Results to date show the NASA cell to be a promising design for both high power-to-weight fuel cell and electrolyzer applications.

  5. Textile for heart valve prostheses: fabric long-term durability testing.

    Science.gov (United States)

    Heim, Frederic; Durand, Bernard; Chakfe, Nabil

    2010-01-01

    The rapid developments and success in percutaneous vascular surgery over the last two decades with the now common stent grafts implantation, make the noninvasive surgery technique today attractive even for heart valve replacement. Less traumatic for the patient and also less time consuming, percutaneous heart valve replacement is however at its beginning and restricted to end of life patients. The noninvasive procedure expects from the heart valve prosthesis material to be resistant and adapted to folding requirements of the implantation process (catheter). Polyester fabric could be a suited material for heart valve implanted percutaneously. Highly flexible and resistant, polyester fabric proved to be well adapted to the dynamic behavior of a valve and polyester (Dacron) is also widely used for vascular grafts implantation and shows good biocompatibility and durability. However, today there's no data available on long-term durability of fabric used as heart valve material. The purpose of this work is to study the long term behavior of a microdenier polyester fabric construction under combined in vitro flexure and tension fatigue stress. In the novel in vitro testing technique presented, a fabric specimen was subjected to combined flexural and tensile fatigue generated by fluid flow under physiological pressure conditions. The results obtained show how flexural properties change with fatigue time, which reflects directly on the suitability of a fabric in such devices. It was also observed that these fabric structural changes directly influence the in vitro behavior of the textile heart valve prosthesis. (c) 2009 Wiley Periodicals, Inc.

  6. Short-term stability test for thorium soil candidate a reference material

    Energy Technology Data Exchange (ETDEWEB)

    Clain, Almir F.; Fonseca, Adelaide M.G.; Dantas, Vanessa V.D.B.; Braganca, Maura J.C.; Souza, Poliana S., E-mail: almir@ird.gov.br, E-mail: adelaide@ird.gov.br, E-mail: vanessa@ird.gov.br, E-mail: maura@ird.gov.br, E-mail: poliana@bolsista.ird.gov.br [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2015-07-01

    This work describes a methodology to determine the soil short-term stability after the steps of production in laboratory. The short-term stability of the soil is an essential property to be determined in order to producing a reference material. The soil is a candidate of reference material for chemical analysis of thorium with metrological traceability to be used in environmental analysis, equipment calibration, validation methods, and quality control. A material is considered stable in a certain temperature if the property of interest does not change with time, considering the analytical random fluctuations. Due to this, the angular coefficient from the graphic of Th concentration versus elapsed time must be near to zero. The analytical determinations of thorium concentration were performed by Instrumental Neutron activation Analysis. The slopes and their uncertainties were obtained from the regression lines at temperatures of 20 deg C and 60 deg C, with control temperature of -20 deg C. From the obtained data a t-test was applied. In both temperatures the calculated t-value was lower than the critical value, so we can conclude with 95% confidence level that no significant changes happened during the period studied concerning thorium concentration in soil at temperatures of 20 deg C and 60 deg C, showing stability at these temperatures. (author)

  7. Short-term stability test for thorium soil candidate a reference material

    International Nuclear Information System (INIS)

    Clain, Almir F.; Fonseca, Adelaide M.G.; Dantas, Vanessa V.D.B.; Braganca, Maura J.C.; Souza, Poliana S.

    2015-01-01

    This work describes a methodology to determine the soil short-term stability after the steps of production in laboratory. The short-term stability of the soil is an essential property to be determined in order to producing a reference material. The soil is a candidate of reference material for chemical analysis of thorium with metrological traceability to be used in environmental analysis, equipment calibration, validation methods, and quality control. A material is considered stable in a certain temperature if the property of interest does not change with time, considering the analytical random fluctuations. Due to this, the angular coefficient from the graphic of Th concentration versus elapsed time must be near to zero. The analytical determinations of thorium concentration were performed by Instrumental Neutron activation Analysis. The slopes and their uncertainties were obtained from the regression lines at temperatures of 20 deg C and 60 deg C, with control temperature of -20 deg C. From the obtained data a t-test was applied. In both temperatures the calculated t-value was lower than the critical value, so we can conclude with 95% confidence level that no significant changes happened during the period studied concerning thorium concentration in soil at temperatures of 20 deg C and 60 deg C, showing stability at these temperatures. (author)

  8. Fabrication and installment of the hard-wired I and C works for the neutral beam injection test stand of the K-STAR project

    International Nuclear Information System (INIS)

    Jung, Ki Sok; Oh, Byung Hun

    2004-12-01

    Instrumentation and Control(I and C) of the neutral beam injection test stand (NBI-TS) for the K-STAR national fusion research project has been underway since the start of the project to answer the diverse requests arising from the various facets of the development and construction phases of the project. In a parallel effort with the software oriented I and C development, there has been existing an enormous amount of hard-wiring I and C works for the NBI facility to be developed and fabricated in schedule. Circuits and hardwired functions have been designed, tested, fabricated, and finally installed to the relevant parts of the system. Examples of those hard-wired I and C works are related to the vacuum system, gas feeding system, arc detector circuit, ion source monitoring, bending magnet and calorimeter. Another one to be mentioned is the interlock circuitry. One of the interlock circuits are related to the coolant flow failure. The other is the interlock circuit related to the vacuum failure. All of the above mentioned circuitry now constitutes integral parts for the proper operation of the NBI system; details of those hard-wired I and C work are described in this report

  9. Effect of feeding greater amounts of dietary energy for a short-term with or without eCG injection on reproductive performance, serum metabolites and hormones in ewes.

    Science.gov (United States)

    Habibizad, Javad; Riasi, Ahmad; Kohram, Hamid; Rahmani, Hamid Reza

    2015-09-01

    This study was conducted to compare the effect of transient high-energy diet in a short-term period with or without eCG injection on ovarian follicle development, twining rate, serum metabolites and hormones in ewes. A total of 45 estrous cyclic Naeini ewes were randomly assigned to three experimental groups: 1-Control (control), 2-High energy short-term feeding (HE), and 3-high energy short-term feeding + eCG injection (HEe). Ewes were housed in individual pens with free access to feed and water. The stage of the estrous cycle of all ewes was synchronized by insertion of intravaginal progesterone sponges. Focus feeding started from 4 days before until 1 day after sponge removal. Follicle development was monitored from 4 days before until 1 day after sponge removal and blood samples were taken during this time. Results showed that ewes fed high energy diets (HE and HEe) had greater (P ewes fed high energy diets had less (P ewes. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Long term durability tests of small engines fueled with bio-ethanol / gasoline blends

    International Nuclear Information System (INIS)

    Tippayawong, N.; Kundhawiworn, N.; Jompakdee, W.

    2006-01-01

    The paper presents the result of an ongoing research to evaluate performance and wear of small, single cylinder, naturally aspirated, agricultural spark ignition engines using biomass-derived ethanol and gasoline blends. The reference gasoline fuel was selected to be representative of gasoline typically available in Thailand. Long-term engine tests of 10% and 20% ethanol / gasoline blends as well as the reference fuel were performed at a constant speed of 2300 rpm under part load condition up to 200 operation hours for each fuel type. Engine brake power, specific fuel consumption, carbon deposits and surface wear were measured and compared between neat gasoline and ethanol/ gasoline blends. It was found that blended fuels appeared to affect the engine performance in a similar way and compared well with the base gasoline fuel. From the results obtained, it was found that engine brake power and specific fuel consumption changed slightly with running time and were not found to have any significant change between different fuel blends. There were carbon deposits buildup on the spark plug, the intake port and exhaust valve stem for all fuels used. Surface wear was not significantly different in the test engines between neat gasoline or ethanol/gasoline blend fuelling

  11. Long-term monitoring and field testing of an innovative multistory timber building

    Science.gov (United States)

    Omenzetter, Piotr; Morris, Hugh; Worth, Margaret; Kohli, Varun; Uma, S. R.

    2011-04-01

    An innovative three-story timber building, using self-centering, post-tensioned timber shear walls as the main horizontal load resisting system and lightweight composite timber-concrete floors, has recently been completed in Nelson, New Zealand. It is expected to be the trailblazer for similar but taller structures to be more widely adopted. Performance based standards require an advanced understanding of building responses and in order to meet the need for in-situ performance data the building has been subjected to forced vibration testing and instrumented for continuous monitoring using a total of about 90 data channels to capture its dynamic and long-term responses. The first part of the paper presents a brief discussion of the existing research on the seismic performance of timber frame buildings and footfall induced floor vibrations. An outline of the building structural system, focusing on the novel design solutions, is then discussed. This is followed by the description of the monitoring system. The paper emphasizes the need for optimal placement of a limited number of sensors and demonstrates how this was achieved for monitoring floor vibrations with the help of the effective independence-driving point residue (EfI-DPR) technique. A novel approach to the EfI-DPR method proposed here uses a combinatorial search algorithm that increases the chances of obtaining the globally optimal solution. Finally, the results from the forced vibration tests conducted on the whole building at different construction stages are reviewed.

  12. LHCb VErtex LOcator module characterisation and long term quality assurance tests

    CERN Document Server

    Bates, A; Doherty, F; Dumps, R; Dwyer, L; Gersabeck, M; Marinho, 1, F; Melone, J; Parkes, C; Saavedra, A; Tobin, M; Viret, S

    2009-01-01

    LHCb is the dedicated b-physics experiment of the LHC. Its vertex detector, the VErtex LOcator (VELO), will operate in a harsh radiation environment with limited access due to its proximity to the LHC beam. To ensure the long term operation and performance, every module was required to pass a set of quality assurance tests. These were specifically developed for the VELO modules to take into account their operational environment and assembly steps. Each VELO module was rigorously inspected, tested and thermally cycled in the Glasgow module burn-in procedures. This paper provides details of the burn-in procedures and summarises the main results that were found. Some of the major results presented in this paper are: the full characterisation of the leakage currents; identification of bad channels; and signal to noise measurements. A few minor problems were identified through visual inspections of the modules and the feedback into the production process proved critical. As a result of the electrical and thermal t...

  13. Water Associated Zero Maze: A novel rat test for long term traumatic re-experiencing

    Directory of Open Access Journals (Sweden)

    Gilad eRitov

    2014-01-01

    Full Text Available Often, freezing and startle behaviors in the context of a previously experienced stress are taken as an indication of posttraumatic stress disorder (PTSD-like symptoms in rats. However, PTSD is characterized by large individual variations of symptoms. In order to take into consideration the complex and long term distinctive variations in effects of trauma exposure additional behavioral measures are required.The current study used a novel behavioral test, the Water Associated Zero Maze (WAZM. This test was planned to enable a formation of an association between the context of the maze and an underwater trauma or swim stress in order to examine the impact of exposure to the context which immediately precedes a stressful or a traumatic experience on rat's complex behavior. Rats were exposed to the WAZM and immediately after to an underwater trauma or short swim. One month later rats were re-exposed to the context of the WAZM while their behavior was video recorded. Furthermore, c-Fos expression in the amygdala was measured 90 min after this exposure.The results of the current study indicate that the WAZM can be used to discern behavioral changes measured a long time after the actual traumatic or stressful events. Furthermore, the behavioral changes detected were accompanied by changes of c-Fos expression in the amygdala of exposed rats. We suggest that the WAZM can be used to model traumatic memories re-experiencing in rodent models of human stress-related pathologies such as PTSD.

  14. LISA Pathfinder test-mass charging during galactic cosmic-ray flux short-term variations

    Science.gov (United States)

    Grimani, C.; Fabi, M.; Lobo, A.; Mateos, I.; Telloni, D.

    2015-02-01

    Metal free-floating test masses aboard the future interferometers devoted to gravitational wave detection in space are charged by galactic and solar cosmic rays with energies \\gt 100 MeV/n. This process represents one of the main sources of noise in the lowest frequency band (\\lt 10-3 Hz) of these experiments. We study here the charging of the LISA Pathfinder (LISA-PF) gold-platinum test masses due to galactic cosmic-ray (GCR) protons and helium nuclei with the Fluka Monte Carlo toolkit. Projections of the energy spectra of GCRs during the LISA-PF operations in 2015 are considered. This work was carried out on the basis of the solar activity level and solar polarity epoch expected for LISA-PF. The effects of GCR short-term variations are evaluated here for the first time. Classical Forbush decreases, GCR variations induced by the Sun rotation, and fluctuations in the LISA-PF frequency bandwidth are discussed.

  15. Two injection digital block versus single subcutaneous palmar injection block for finger lacerations.

    Science.gov (United States)

    Okur, O M; Şener, A; Kavakli, H Ş; Çelik, G K; Doğan, N Ö; Içme, F; Günaydin, G P

    2017-12-01

    We aimed to compare two digital nerve block techniques in patients due to traumatic digital lacerations. This was a randomized-controlled study designed prospectively in the emergency department of a university-based training and research hospital. Randomization was achieved by sealed envelopes. Half of the patients were randomised to traditional (two-injection) digital nerve block technique while single-injection digital nerve block technique was applied to the other half. Score of pain due to anesthetic infiltration and suturing, onset time of total anesthesia, need for an additional rescue injection were the parameters evaluated with both groups. Epinephrin added lidocaine hydrochloride preparation was used for the anesthetic application. Visual analog scale was used for the evaluation of pain scores. Outcomes were compared by using Mann-Whitney U test and Student t-test. Fifty emergency department patients ≥18 years requiring digital nerve block were enrolled in the study. Mean age of the patients was 33 (min-max: 19-86) and 39 (78 %) were male. No statistically significant difference was found between the two groups in terms of our main parameters; anesthesia pain score, suturing pain score, onset time of total anesthesia and rescue injection need. Single injection volar digital nerve block technique is a suitable alternative for digital anesthesias in emergency departments.

  16. Botox Injections

    Science.gov (United States)

    ... Awards | Feedback COPYRIGHT 2018 | AMERICAN ACADEMY OF FACIAL PLASTIC AND RECONSTRUCTIVE SURGERY (AAFPRS) | ALL RIGHTS RESERVED TERMS OF USE | PRIVACY POLICY | SITEMAP | CONTACT | Plastic Surgery Marketing by ...

  17. Testing the effectiveness of cognitive interventions in alleviating accelerated long term forgetting (ALF).

    Science.gov (United States)

    Ricci, Monica; Wong, Toh; Nikpour, Armin; Miller, Laurie A

    2017-10-23

    It is well established that when retrieval or other forms of testing follow shortly after the acquisition of new information, long-term memory is improved in healthy subjects (Roediger & Karpicke, 2006). It is not known whether such early interventions would alleviate ALF, a condition in which early retention is normal, but there is a steep decline over longer intervals. A different behavioral intervention (i.e., an interposed recall of a story after a longer delay) was found to prevent subsequent memory loss in a single case with ALF (Jansari, Davis, McGibbon, Firminger, & Kapur, 2010; McGibbon & Jansari, 2013), but this has yet to be replicated. In the present study, we sought to test the effectiveness of early rehearsal as well as a later interposed recall on long term memory. Three men with ALF and 10 matched, healthy males (mean age = 67 yr; mean education = 15 yr) were compared for story recall following 3 early intervention conditions. There were two early rehearsal conditions: Repeated-Recall (2 additional recalls were requested in the initial 30 min interval) and Repeated Recall With Discussion (2 additional recalls plus discussion occurred in the initial 30 min interval) as well as a Control condition, in which there was no additional rehearsal in the first 30 min. Memory for 6 stories (2 in each condition) was tested at 0 min, 30 min, 1 day, 1 week and 4 weeks. In addition, to evaluate the possible sustaining effect of an additional retrieval ("booster recall") between 1 wk and 4 wk delays, 1 story from each of the early intervention conditions was recalled at 2 weeks' delay. Consistent with the profile characteristic of ALF, nonparametric statistics revealed no group differences at 0 or 30 min recalls. For Control stories, the ALF group's recall was impaired by 24 h delay. For stories in either of the early rehearsal conditions, the patients showed better retention, performing within normal limits until the 4 week recall. The "booster

  18. Long-Term Reliability of SiGe/Si HBTs From Accelerated Lifetime Testing

    Science.gov (United States)

    Bhattacharya, Pallab

    2001-01-01

    Accelerated lifetime tests were performed on double-mesa structure Si(0.7)Ge(0.3)/Si npn heterojunction bipolar transistors, grown by molecular beam epitaxy, in the temperature range of 175 C-275 C. The transistors (with 5x20 sq micron emitter area) have DC current gains approx. 40-50 and f(sub T) and f(sub max) of up to 22 GHz and 25 GHz, respectively. It is found that a gradual degradation in these devices is caused by the recombination enhanced impurity diffusion (REID) of boron atoms from the p-type base region and the associated formation of parasitic energy barriers to electron transport from the emitter to collector layers. This REED has been quantitatively modeled and explained, to the first order of approximation, and the agreement with the measured data is good. The mean time to failure (MTTF) of these devices at room temperature under 1.35 x 10(exp 4) A/sq cm current density operation is estimated from the extrapolation of the Arrhenius plots of device lifetime versus reciprocal temperature. The results of the reliability tests offer valuable feedback for SiGe heterostructure design in order to improve the long-term reliability of the devices and circuits made with them. Hot electron induced degradation of the base-emitter junction was also observed during the accelerated lifetime testing. In order to improve the HBT reliability endangered by the hot electrons, deuterium sintered techniques have been proposed. The preliminary results from this study show that a deuterium-sintered HBT is, indeed, more resistant to hot-electron induced base-emitter junction degradation.

  19. Long-term leach testing of solidified radioactive waste forms (International Standard Publication ISO 6961:1982)

    International Nuclear Information System (INIS)

    Stefanik, J.

    2001-01-01

    Processes are developed for the immobilization of radionuclides by solidification of radioactive wastes. The resulting solidification products are characterized by strong resistance to leaching aimed at low release rates of the radionuclides to the environment. To measure this resistance to leaching of the solidified materials: glass, glass-ceramics, bitumen, cement, concrete, plastics, a long-term leach test is presented. The long-term leach test is aimed at: a) the comparison of different kinds or compositions of solidified waste forms; b) the intercomparison between leach test results from different laboratories on one product; c) the intercomparison between leach test results on products from different processes

  20. Hydrologic Source Term Processes and Models for the Clearwater and Wineskin Tests, Rainier Mesa, Nevada National Security Site

    Energy Technology Data Exchange (ETDEWEB)

    Carle, Steven F. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2011-05-04

    This report describes the development, processes, and results of a hydrologic source term (HST) model for the CLEARWATER (U12q) and WINESKIN (U12r) tests located on Rainier Mesa, Nevada National Security Site, Nevada (Figure 1.1). Of the 61 underground tests (involving 62 unique detonations) conducted on Rainier Mesa (Area 12) between 1957 and 1992 (USDOE, 2015), the CLEARWATER and WINESKIN tests present many unique features that warrant a separate HST modeling effort from other Rainier Mesa tests.

  1. Corrosion of metals in wood : comparing the results of a rapid test method with long-term exposure tests across six wood treatments

    Science.gov (United States)

    Samuel L. Zelinka; Donald S. Stone

    2011-01-01

    This paper compares two methods of measuring the corrosion of steel and galvanized steel in wood: a long-term exposure test in solid wood and a rapid test method where fasteners are electrochemically polarized in extracts of wood treated with six different treatments. For traditional wood preservatives, the electrochemical extract method correlates with solid wood...

  2. Effects of long-term intraperitoneal injection of thyrotropin-releasing hormone (TRH) on aging- and obesity-related changes in body weight, lipid metabolism, and thyroid functions.

    Science.gov (United States)

    Pierpaoli, Walter; Lesnikov, Vladimir A

    2011-02-01

    Adult adipose mice, high fat diet-fed (HFD) mice, anterior hypothalamus-lesioned obese mice and genetically obese mice, were injected daily with thyrotropin releasing hormone (TRH). The treatment provoked a mobilization of triglycerides in the peripheral blood, a decrease of leptin and a loss of body weight. The weight loss did not depend on TSH-mediated stimulation of thyroid hormone secretion with consequent metabolic hyperthyroidism. The levels of blood cholesterol were not affected or even suppressed. Even at a very high dosage TRH did not affect the obesity of genetically obese mice. The ubiquitous tripeptide TRH may thus constitute a key element in the hormone-controlled regulation of body weight and fat stores in the adult and aging body.

  3. The Role of Long-Term Memory in a Test of Visual Working Memory: Proactive Facilitation but No Proactive Interference

    Science.gov (United States)

    Oberauer, Klaus; Awh, Edward; Sutterer, David W.

    2017-01-01

    We report 4 experiments examining whether associations in visual working memory are subject to proactive interference from long-term memory (LTM). Following a long-term learning phase in which participants learned the colors of 120 unique objects, a working memory (WM) test was administered in which participants recalled the precise colors of 3…

  4. Injectable barriers for waste isolation

    International Nuclear Information System (INIS)

    Persoff, P.; Finsterle, S.; Moridis, G.J.; Apps, J.; Pruess, K.; Muller, S.J.

    1995-03-01

    In this paper the authors report laboratory work and numerical simulation done in support of development and demonstration of injectable barriers formed from either of two fluids: colloidal silica or polysiloxane. Two principal problems addressed here are control of gel time and control of plume emplacement in the vadose zone. Gel time must be controlled so that the viscosity of the barrier fluid remains low long enough to inject the barrier, but increases soon enough to gel the barrier in place. During injection, the viscosity must be low enough to avoid high injection pressures which could uplift or fracture the formation. To test the grout gel time in the soil, the injection pressure was monitored as grouts were injected into sandpacks. When grout is injected into the vadose zone, it slumps under the influence of gravity, and redistributes due to capillary forces as it gels. The authors have developed a new module for the reservoir simulator TOUGH2 to model grout injection into the vadose zone, taking into account the increase of liquid viscosity as a function of gel concentration and time. They have also developed a model to calculate soil properties after complete solidification of the grout. The numerical model has been used to design and analyze laboratory experiments and field pilot tests. The authors present the results of computer simulations of grout injection, redistribution, and solidification

  5. Computational Bench Testing to Evaluate the Short-Term Mechanical Performance of a Polymeric Stent.

    Science.gov (United States)

    Bobel, A C; Petisco, S; Sarasua, J R; Wang, W; McHugh, P E

    2015-12-01

    Over the last decade, there has been a significant volume of research focussed on the utilization of biodegradable polymers such as poly-L-lactide-acid (PLLA) for applications associated with cardiovascular disease. More specifically, there has been an emphasis on upgrading current clinical shortfalls experienced with conventional bare metal stents and drug eluting stents. One such approach, the adaption of fully formed polymeric stents has led to a small number of products being commercialized. Unfortunately, these products are still in their market infancy, meaning there is a clear non-occurrence of long term data which can support their mechanical performance in vivo. Moreover, the load carry capacity and other mechanical properties essential to a fully optimized polymeric stent are difficult, timely and costly to establish. With the aim of compiling rapid and representative performance data for specific stent geometries, materials and designs, in addition to reducing experimental timeframes, Computational bench testing via finite element analysis (FEA) offers itself as a very powerful tool. On this basis, the research presented in this paper is concentrated on the finite element simulation of the mechanical performance of PLLA, which is a fully biodegradable polymer, in the stent application, using a non-linear viscous material model. Three physical stent geometries, typically used for fully polymeric stents, are selected, and a comparative study is performed in relation to their short-term mechanical performance, with the aid of experimental data. From the simulated output results, an informed understanding can be established in relation to radial strength, flexibility and longitudinal resistance, that can be compared with conventional permanent metal stent functionality, and the results show that it is indeed possible to generate a PLLA stent with comparable and sufficient mechanical performance. The paper also demonstrates the attractiveness of FEA as a tool

  6. Military chemical warfare agent human subjects testing: part 2--long-term health effects among participants of U.S. military chemical warfare agent testing.

    Science.gov (United States)

    Brown, Mark

    2009-10-01

    Military chemical warfare agent testing from World War I to 1975 produced thousands of veterans with concerns about how their participation affected their health. A companion article describes the history of these experiments, and how the lack of clinical data hampers evaluation of long-term health consequences. Conversely, much information is available about specific agents tested and their long-term health effects in other populations, which may be invaluable for helping clinicians respond effectively to the health care and other needs of affected veterans. The following review describes tested agents and their known long-term health consequences. Although hundreds of chemicals were tested, they fall into only about a half-dozen pharmaceutical classes, including common pharmaceuticals; anticholinesterase agents including military nerve agents and pesticides; anticholinergic glycolic acid esters such as atropine; acetylcholine reactivators such as 2-PAM; psychoactive compounds including cannabinoids, phencyclidine, and LSD; and irritants including tear gas and riot control agents.

  7. Long-term product consistency test of simulated 90-19/Nd HLW glass

    International Nuclear Information System (INIS)

    Gan, X.Y.; Zhang, Z.T.; Yuan, W.Y.; Wang, L.; Bai, Y.; Ma, H.

    2011-01-01

    Chemical durability of 90-19/Nd glass, a simulated high-level waste (HLW) glass in contact with the groundwater was investigated with a long-term product consistency test (PCT). Generally, it is difficult to observe the long term property of HLW glass due to the slow corrosion rate in a mild condition. In order to overcome this problem, increased contacting surface (S/V = 6000 m -1 ) and elevated temperature (150 o C) were employed to accelerate the glass corrosion evolution. The micro-morphological characteristics of the glass surface and the secondary minerals formed after the glass alteration were analyzed by SEM-EDS and XRD, and concentrations of elements in the leaching solution were determined by ICP-AES. In our experiments, two types of minerals, which have great impact on glass dissolution, were found to form on 90-19/Nd HLW glass surface when it was subjected to a long-term leaching in the groundwater. One is Mg-Fe-rich phyllosilicates with honeycomb structure; the other is aluminosilicates (zeolites). Mg and Fe in the leaching solution participated in the formation of phyllosilicates. The main components of phyllosilicates in alteration products of 90-19/Nd HLW glass are nontronite (Na 0.3 Fe 2 Si 4 O 10 (OH) 2 .4H 2 O) and montmorillonite (Ca 0.2 (Al,Mg) 2 Si 4 O 10 (OH) 2 .4H 2 O), and those of aluminosilicates are mordenite ((Na 2 ,K 2 ,Ca)Al 2 Si 10 O 24 .7H 2 O)) and clinoptilolite ((Na,K,Ca) 5 Al 6 Si 30 O 72 .18H 2 O). Minerals like Ca(Mg)SO 4 and CaCO 3 with low solubility limits are prone to form precipitant on the glass surface. Appearance of the phyllosilicates and aluminosilicates result in the dissolution rate of 90-19/Nd HLW glass resumed, which is increased by several times over the stable rate. As further dissolution of the glass, both B and Na in the glass were found to leach out in borax form.

  8. Analysis of the Variability of Classified and Unclassified Radiological Source term Inventories in the Frenchman Flat Area, Nevada test Site

    International Nuclear Information System (INIS)

    Zhao, P.; Zavarin, M.

    2008-01-01

    It has been proposed that unclassified source terms used in the reactive transport modeling investigations at NTS CAUs should be based on yield-weighted source terms calculated using the average source term from Bowen et al. (2001) and the unclassified announced yields reported in DOE/NV-209. This unclassified inventory is likely to be used in unclassified contaminant boundary calculations and is, thus, relevant to compare to the classified inventory. They have examined the classified radionuclide inventory produced by 10 underground nuclear tests conducted in the Frenchman Flat (FF) area of the Nevada Test Site. The goals were to (1) evaluate the variability in classified radiological source terms among the 10 tests and (2) compare that variability and inventory uncertainties to an average unclassified inventory (e.g. Bowen 2001). To evaluate source term variability among the 10 tests, radiological inventories were compared on two relative scales: geometric mean and yield-weighted geometric mean. Furthermore, radiological inventories were either decay corrected to a common date (9/23/1992) or the time zero (t 0 ) of each test. Thus, a total of four data sets were produced. The date of 9/23/1992 was chosen based on the date of the last underground nuclear test at the Nevada Test Site

  9. Glaukos iStent inject® Trabecular Micro-Bypass Implantation Associated with Cataract Surgery in Patients with Coexisting Cataract and Open-Angle Glaucoma or Ocular Hypertension: A Long-Term Study

    Directory of Open Access Journals (Sweden)

    Pedro Arriola-Villalobos

    2016-01-01

    Full Text Available Purpose. To evaluate the long-term efficacy and safety of the iStent inject device (Glaukos Corporation, Laguna Hills, CA combined with phacoemulsification in patients with coexistent cataract and open-angle glaucoma or ocular hypertension (OHT. Methods. A prospective, uncontrolled, nonrandomized, interventional case series study was conducted in patients with both mild or moderate open-angle glaucoma or OHT and cataract. Patients underwent cataract surgery along with the implant of two iStent inject devices. Outcome measures were intraocular pressure (IOP, topical hypotensive medications required, and best-corrected visual acuity (BCVA. Results. 20 patients were enrolled. Mean follow-up was 47.4±18.46 months. Mean baseline IOP was 19.95±3.71 mmHg with medication and 26±3.11 mmHg after washout. Mean end-follow-up IOP was 16.25±1.99 mmHg, representing an IOP decrease of 36.92%, 9.74±3.14 mmHg (P<0.001, from baseline washout IOP. The mean number of medications was significantly reduced from 1.3±0.66 to 0.75±0.79 (P=0.017. 45% of patients were medication-free by the end of follow-up. Mean log⁡MAR BCVA improved significantly from 0.42±0.16 to 0.18±0.16 (P<0.001. No complications of surgery were observed. Conclusion. The iStent inject device combined with cataract surgery served to significantly reduce both IOP and medication use in the long term in patients with coexistent open-angle glaucoma or ocular hypertension (OHT and cataract.

  10. Designing a Prototype LPG Injection Electronic Control Unit for a Carburetted Gasoline Engine

    Directory of Open Access Journals (Sweden)

    Barış ERKUŞ

    2015-07-01

    Full Text Available In this study, the originally carburetted gasoline engine was converted to gas-phase liquefied petroleum gas (LPG injection engine by using an after market LPG conversion kit's components except the electronic control unit (ECU. Instead of after market LPG injection ECU, the ECU which was designed considering the effects of  electromagnetic interference (EMI, was used for controlling injection. The designed ECU was tested in terms of EMI while the engine was being run and it was detected that the EMI noises could be suppressed as possible by taken measures. Designed ECU was used in performance tests at different engine conditions and the results obtained with LPG injection were compared with the results obtained with LPG carburetion. According to the performance test results, LPG injection ECU designed in this study could help to achieve low exhaust emissions and high engine performance.  

  11. LMFBR source term experiments in the Fuel Aerosol Simulant Test (FAST) facility

    International Nuclear Information System (INIS)

    Petrykowski, J.C.; Longest, A.W.

    1985-01-01

    The transport of uranium dioxide (UO 2 ) aerosol through liquid sodium was studied in a series of ten experiments in the Fuel Aerosol Simulant Test (FAST) facility at Oak Ridge National Laboratory (ORNL). The experiments were designed to provide a mechanistic basis for evaluating the radiological source term associated with a postulated, energetic core disruptive accident (CDA) in a liquid metal fast breeder reactor (LMFBR). Aerosol was generated by capacitor discharge vaporization of UO 2 pellets which were submerged in a sodium pool under an argon cover gas. Measurements of the pool and cover gas pressures were used to study the transport of aerosol contained by vapor bubbles within the pool. Samples of cover gas were filtered to determine the quantity of aerosol released from the pool. The depth at which the aerosol was generated was found to be the most critical parameter affecting release. The largest release was observed in the baseline experiment where the sample was vaporized above the sodium pool. In the nine ''undersodium'' experiments aerosol was generated beneath the surface of the pool at depths varying from 30 to 1060 mm. The mass of aerosol released from the pool was found to be a very small fraction of the original specimen. It appears that the bulk of aerosol was contained by bubbles which collapsed within the pool. 18 refs., 11 figs., 4 tabs

  12. Short-term effect of dark chocolate consumption on routine haemostasis testing.

    Science.gov (United States)

    Montagnana, Martina; Danese, Elisa; Salvagno, Gian Luca; Lippi, Giuseppe

    2017-08-01

    This experimental study was designed to investigate the sort-term impact of dark chocolate ingestion on routine haemostasis tests in healthy volunteers. The study population consisted in 15 healthy male volunteers who ingested 50 g of 90% cocoa chocolate within 3-5 min. Blood was drawn early in the morning, immediately before chocolate ingestion and 4 h afterwards, for assessment of activated partial thromboplastin time (APTT), prothrombin time (PT) and fibrinogen. A significant increase of triglycerides (1.4 ± 0.6 versus 1.0 ± 0.5 mmol/L; p < .001), APTT (32.1 ± 2.2 versus 31.1 ± 2.0 s; p < .001) and PT (9.8 ± 0.5 versus 9.7 ± 0.4 s; p = .008) was observed 4 h after ingestion of dark chocolate, whereas fibrinogen values remained unchanged (2.6 ± 0.5 versus 2.5 ± 0.5 g/L; p = .063). Overall, we observed a mean percentage increase of 3.1% for APTT and 1.2% for PT. These results suggest that dark chocolate intake may have an impact on secondary haemostasis.

  13. Long-term aging and loss-of-coolant accident (LOCA) testing of electrical cables

    International Nuclear Information System (INIS)

    Nelson, C.F.; Gauthier, G.; Carlin, F.

    1996-10-01

    Experiments were performed to assess the aging degradation and loss-of-coolant accident (LOCA) behavior of electrical cables subjected to long-term aging exposures. Four different cable types were tested in both the U.S. and France: (1) U.S. 2 conductor with ethylene propylene rubber (EPR) insulation and a Hypalon jacket. (2) U.S. 3 conductor with cross-linked polyethylene (XLPE) insulation and a Hypalon jacket. (3) French 3 conductor with EPR insulation and a Hypalon jacket. (4) French coaxial with polyethylene (PE) insulation and a PE jacket. The data represent up to 5 years of simultaneous aging where the cables were exposed to identical aging radiation doses at either 40 degrees C or 70 degrees C; however, the dose rate used for the aging irradiation was varied over a wide range (2-100 Gy/hr). Aging was followed by exposure to simulated French LOCA conditions. Several mechanical, electrical, and physical-chemical condition monitoring techniques were used to investigate the degradation behavior of the cables. All the cables, except for the French PE cable, performed acceptably during the aging and LOCA simulations. In general, cable degradation at a given dose was highest for the lowest dose rate, and the amount of degradation decreased as the dose rate was increased

  14. A Methodological Approach for Testing the Viability of Seeds Stored in Short-Term Seed Banks

    Directory of Open Access Journals (Sweden)

    Jose A. FORTE GIL

    2017-12-01

    Full Text Available Efficient management of ‘active’ seed banks – specifically aimed at the short-term storage at room temperature of seeds to be used locally in conservation/regeneration programmes of endemic or endangered plant species – requires establishing the optimal storage time to maintain high seed viability, for each stored species. In this work, germination of seeds of the halophytes Thalictrum maritimum, Centaurea dracunculifolia and Linum maritimum has been investigated. The seeds had been stored for different periods of time in the seed bank of ‘La Albufera’ Natural Park (Valencia, SE Spain after collection in salt marshes of the Park, where small populations of the three species are present. Seeds of T. maritimum and C. dracunculifolia have a relatively short period of viability at room temperature, and should not be stored for more than three years. On the other hand, L. maritimum seeds maintain a high germination percentage and can be kept at room temperature for up to 10 years. T. maritimum seeds, in contrast to those of the other two species, did not germinate in in vitro tests nor when sown directly on a standard substrate, unless a pre-treatment of the seeds was applied, mechanical scarification being the most effective. These results will help to improve the management of the seed bank, to generate more efficiently new plants for reintroduction and reinforcement of populations of these species in their natural ecosystems within the Natural Park.

  15. Long-term field test of solar PV power generation using one-axis 3-position sun tracker

    KAUST Repository

    Huang, B.J.; Ding, W.L.; Huang, Y.C.

    2011-01-01

    The 1 axis-3 position (1A-3P) sun tracking PV was built and tested to measure the daily and long-term power generation of the solar PV system. A comparative test using a fixed PV and a 1A-3P tracking PV was carried out with two identical stand

  16. Fibrous Myopathy as a Complication of Repeated Intramuscular Injections for Chronic Headache

    Directory of Open Access Journals (Sweden)

    R Burnham

    2006-01-01

    Full Text Available Two cases of fibrous myopathy associated with repeated, long-term intramuscular injections for treatment of chronic temporomandibular joint pain and chronic headache, respectively, are described. Both patients developed severe, function-limiting contractures in upper and lower extremity muscles used as injection sites. In one of the cases, the contractures were painful. Electrophysiological testing, magnetic resonance imaging and muscle biopsy results were all consistent with myopathy and replacement of skeletal muscle with noncontractile fibrous tissue. These cases are presented to increase awareness of fibrous myopathy and to promote surveillance for this serious potential complication of long-term intramuscular injections in chronic headache and other pain patients.

  17. Long-term performance of colorectal cancer screening programmes based on the faecal immunochemical test.

    Science.gov (United States)

    Zorzi, Manuel; Hassan, Cesare; Capodaglio, Giulia; Fedato, Chiara; Montaguti, Adriana; Turrin, Anna; Rosano, Alberto; Monetti, Daniele; Stocco, Carmen; Baracco, Susanna; Russo, Francesca; Repici, Alessandro; Rugge, Massimo

    2017-11-03

    The long-term performance of colorectal cancer (CRC) screening programmes based on a 2-year faecal immunochemical test (FIT) is still unclear. In a sample of 50 to 69-year-olds repeatedly screened with the FIT (OC-Hemodia latex agglutination test; cut-off: 20 µg haemoglobin/g faeces), we examined: (1) the FIT positivity rate, the CRC and advanced adenoma detection rate and the FIT's positive predictive value (PPV) for advanced neoplasia, at each round of screening and (2) the cumulative CRC and advanced adenoma detection rate after five rounds of FIT. Over 12 years (2002-2014), 123 347 individuals were administered the FIT up to six times, and 781 CRCs and 4713 advanced adenomas were diagnosed. The CRC and advanced adenoma detection rates declined substantially from the first to the third (rate ratio (RR) 0.25, 95% CI 0.20 to 0.32) and second (RR 0.51, 95% CI 0.47 to 0.56) rounds, respectively, and then remained stable. The PPV for advanced neoplasia dropped by 18% in the second round (RR 0.82, 95% CI 0.77 to 0.89), with no further reduction thereafter due to a concomitant decline in the FIT positivity rate (RR first to sixth rounds: 0.56, 95% CI 0.53 to 0.60).The cumulative CRC and advanced adenoma detection rates over five consecutive rounds were 8.5‰ (95% CI 7.8 to 9.2), and 58.9‰ (95% CI 56.9 to 61.0), respectively. Repeated FIT significantly reduces the burden of colorectal disease while facilitating an efficient use of colonoscopy resources. The cumulative detection rate after five rounds of FIT is similar to primary screening with colonoscopy, supporting the need to account for the cumulative sensitivity of repeated FITs when evaluating the test's efficacy. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  18. Safe injection procedures, injection practices, and needlestick ...

    African Journals Online (AJOL)

    Results: Safe injection procedures regarding final waste disposal were sufficiently adopted, while measures regarding disposable injection equipment, waste containers, hand hygiene, as well as injection practices were inadequately carried out. Lack of job aid posters that promote safe injection and safe disposal of ...

  19. Short-term adhesion and long-term biofouling testing of polydopamine and poly(ethylene glycol) surface modifications of membranes and feed spacers for biofouling control

    KAUST Repository

    Miller, Daniel J.

    2012-08-01

    Ultrafiltration, nanofiltration membranes and feed spacers were hydrophilized with polydopamine and polydopamine- g-poly(ethylene glycol) surface coatings. The fouling propensity of modified and unmodified membranes was evaluated by short-term batch protein and bacterial adhesion tests. The fouling propensity of modified and unmodified membranes and spacers was evaluated by continuous biofouling experiments in a membrane fouling simulator. The goals of the study were: 1) to determine the effectiveness of polydopamine and polydopamine- g-poly(ethylene glycol) membrane coatings for biofouling control and 2) to compare techniques commonly used in assessment of membrane biofouling propensity with biofouling experiments under practical conditions. Short-term adhesion tests were carried out under static, no-flow conditions for 1 h using bovine serum albumin, a common model globular protein, and Pseudomonas aeruginosa, a common model Gram-negative bacterium. Biofouling tests were performed in a membrane fouling simulator (MFS) for several days under flow conditions similar to those encountered in industrial modules with the autochthonous drinking water population and acetate dosage as organic substrate. Polydopamine- and polydopamine- g-poly(ethylene glycol)-modified membranes showed significantly reduced adhesion of bovine serum albumin and P. aeruginosa in the short-term adhesion tests, but no reduction of biofouling was observed during longer biofouling experiments with modified membranes and spacers. These results demonstrate that short-term batch adhesion experiments using model proteins or bacteria under static conditions are not indicative of biofouling, while continuous biofouling experiments showed that membrane surface modification by polydopamine and polydopamine- g-poly(ethylene glycol) is not effective for biofouling control. © 2012 Elsevier Ltd.

  20. Tests of US rock salt for long-term stability of CAES reservoirs

    Energy Technology Data Exchange (ETDEWEB)

    Gehle, R.M.; Thoms, R.L.

    1986-01-01

    This is a report on laboratory tests to assess the effects of compressed air energy storage (CAES) on rock salt within the US. The project included a conventional laboratory test phase, with triaxial test machines, and a bench-scale test phase performed in salt mines in southern Louisiana. Limited numerical modeling also was performed to serve as a guide in selecting test layouts and for interpreting test data.

  1. Schizophrenia symptoms and functioning in patients receiving long-term treatment with olanzapine long-acting injection formulation: a pooled analysis

    Directory of Open Access Journals (Sweden)

    Peuskens Joseph

    2012-08-01

    Full Text Available Abstract Background This analysis of pooled data evaluates treatment outcomes of patients with schizophrenia receiving maintenance treatment with olanzapine long-acting injection (OLAI by means of a categorical approach addressing the symptomatic and functional status of patients at different times. Methods Patients were grouped into 5 categories at baseline, 6 months, and 12 months. Shifts between categories were assessed for individual patients and factors associated with improvement were analyzed. 1182 patients from 3 clinical trials were included in the current analysis. Results At baseline, 434 (36.8% patients had minimal Positive and Negative Syndrome Scale (PANSS symptoms but seriously impaired Heinrich Carpenter’s Quality of Life Scale (QLS functioning; 303 (25.6% had moderate to severe symptoms and seriously impaired function; 208 (17.6% had mild to moderate symptoms but good functioning, and 162 (13.7% had minimal symptoms and good functioning. Baseline category was significantly associated with Clinical Global Impression – Severity (CGI-S, extrapyramidal symptoms, working status, age, and number of previous episodes. The majority of all patients starting OLAI treatment maintained or improved (62% at 6 months and 52% at 12 months their symptom and functioning levels on OLAI maintenance treatment. Less than 8% of the patients showed worsening of symptoms or functioning. An improvement in category was associated with high PANSS positive and low CGI-S scores at baseline. Conclusions We present evidence that a composite assessment of schizophrenic patients including symptom severity and functioning is helpful in the evaluation of maintenance treatment outcomes. This approach could also be useful for the assessment of treatment options in clinical practice. The trials from which data are reported here were registered on clinicaltrials.gov as NCT00088491, NCT00088465, and NCT00320489.

  2. Spray-controlled combustionprocess with piezo injection; Strahlgefuehrtes Brennverfahren mit Piezo-Benzineinspritzung

    Energy Technology Data Exchange (ETDEWEB)

    Schaupp, U.; Altenschmidt, F.; Bertsch, D.; Laudenbach, N. [DaimlerChrysler AG, Stuttgart (Germany)

    2007-07-01

    The novel 2nd generation injection system of Mercedes-Benz have resulted in reduced fuel consumption and lower emissions while improving the engine performance. The piezo technology is a great technical advance. The characteristic field range in which stratified charge operation is possible has been extended since the first generation of injection systems. Lower fuel consumption is achieved not only in normal traffic but also when cruising on motorways at constant speed. The advantages are noticeable not only in the test cycle but also in real operation. The piezo injection valve was not available on the market and had to be constructed, including the 200 bar high-pressure fuel injection system. The stability of the injection system and the good mixing characteristics resulted in an optimally combustible mixture at the spark plug. Apart from stability in stratified charge operation, the possibility of multiple injection also has further advantages and potentials in terms of consumption and emissions. (orig.)

  3. Test of a motor theory of long-term auditory memory.

    Science.gov (United States)

    Schulze, Katrin; Vargha-Khadem, Faraneh; Mishkin, Mortimer

    2012-05-01

    Monkeys can easily form lasting central representations of visual and tactile stimuli, yet they seem unable to do the same with sounds. Humans, by contrast, are highly proficient in auditory long-term memory (LTM). These mnemonic differences within and between species raise the question of whether the human ability is supported in some way by speech and language, e.g., through subvocal reproduction of speech sounds and by covert verbal labeling of environmental stimuli. If so, the explanation could be that storing rapidly fluctuating acoustic signals requires assistance from the motor system, which is uniquely organized to chain-link rapid sequences. To test this hypothesis, we compared the ability of normal participants to recognize lists of stimuli that can be easily reproduced, labeled, or both (pseudowords, nonverbal sounds, and words, respectively) versus their ability to recognize a list of stimuli that can be reproduced or labeled only with great difficulty (reversed words, i.e., words played backward). Recognition scores after 5-min delays filled with articulatory-suppression tasks were relatively high (75-80% correct) for all sound types except reversed words; the latter yielded scores that were not far above chance (58% correct), even though these stimuli were discriminated nearly perfectly when presented as reversed-word pairs at short intrapair intervals. The combined results provide preliminary support for the hypothesis that participation of the oromotor system may be essential for laying down the memory of speech sounds and, indeed, that speech and auditory memory may be so critically dependent on each other that they had to coevolve.

  4. SPEAR 3 INJECTION KICKER

    International Nuclear Information System (INIS)

    2002-01-01

    The design of the SPEAR 3 injection kicker system is presented. This system will include three kicker magnets and their associated pulsers. The magnet design is based on the DELTA kicker magnets, which present a low RF impedance to the beam, and are relatively straight-forward to construct. The pulsers use cascaded IGBT stages that are based on the modulator pulsers developed by a SLAC/LLNL collaboration for the NLC. Design considerations and the results of prototype tests will be discussed

  5. The natural and artificial hydration of a bentonite engineered barrier system in a full-scale KBS-3V mock-up; results from the first 7 years of the large scale gas injection test (LASGIT)

    International Nuclear Information System (INIS)

    Cuss, R.J.; Harrington, J.F.; Noy, D.J.; Bennett, D.P.; Sellin, P.

    2012-01-01

    Document available in extended abstract form only. The Large scale gas injection test is a full-scale in situ canister test designed to answer specific questions regarding the movement of gas through bentonite in a mock KBS-3v deposition hole. The test is located at 420 m depth within SKB's Aespoe Hard Rock Laboratory (HRL) in Sweden. The objective of Lasgit is to provide quantitative data to improve process understanding and test/validate modelling approaches which might be used in performance assessment. The deposition hole has a depth of 8.5 m and a diameter of around 1.75 m. A full scale KBS-3 canister has been modified for the Lasgit experiment with thirteen circular filters of varying dimensions located on its surface to provide point sources for gas injection, mimicking potential canister defects. These filters can also be used to inject water during the hydration stage, with hydration also conducted through 4 filter mats within the buffer. The deposition hole, buffer and canister are equipped with instrumentation to measure the total stress, pore water pressure and relative humidity in 32, 26 and 7 positions respectively. Additional instrumentation continually monitors variations in temperature, relative displacement of the lid and the restraining forces on the rock anchors. Groundwater inflow through a number of highly-conductive discrete fractures quickly resulted in elevated pore water pressures in sections of the borehole. This lead to the formation of conductive channels, the extrusion of bentonite from the deposition hole, and the discharge of groundwater to the gallery floor. Artificial hydration began after 106 days of testing. Up until the first gas injection test (day 843), the pressures in all of the canister filters and hydration mats were used to hydrate the clay. Initial attempts to raise pore water pressure in the artificial hydration arrays occasionally resulted in the formation of preferential pathways resulting in localized increases in

  6. Injection and lessons for 2012

    International Nuclear Information System (INIS)

    Bracco, C.; Barnes, M.J.; Bartmann, W.; Cornelis, K.; Drosdal, L.N.; Goddard, B.; Kain, V.; Meddahi, M.; Mertens, V.; Uythoven, J.

    2012-01-01

    Injection of 144 bunches into the LHC became fully operational during the 2011 run and one nominal injection of 288 bunches was accomplished. Several mitigation solutions were put in place to minimise losses from the Transfer Line (TL) collimators and losses from kicking de-bunched beam during injection. Nevertheless, shot-by- shot and bunch-by-bunch trajectory variations, as well as long terms drifts, were observed and required a regular re-steering of the TL implying a non negligible amount of time spent for injection setup. Likely sources of instability have been identified (i.e. MKE and MSE ripples) and possible cures to optimise 2012 operation are presented. Well defined references for TL steering will be defined in a more rigorous way in order to allow a more straightforward and faster injection setup. Encountered and potential issues of the injection system, in particular the injection kickers MKI, are discussed also in view of injections with a higher number of bunches. (authors)

  7. Injection and lessons for 2012

    CERN Document Server

    Bracco, C; Bartmann, W; Cornelis, K; Drosdal, L N; Goddard, B; Kain, V; Meddahi, M; Mertens, V; Uythoven, J

    2012-01-01

    Injection of 144 bunches into the LHC became fully operational during the 2011 run and a nominal injection of 288 bunches was accomplished during MD time. Several mitigation solutions were put in place to minimise losses from the transfer line (TL) collimators and losses from kicking debunched beam during injection. Nevertheless, shot-by-shot and bunch-by-bunch trajectory variations, as well as long terms drifts, were observed and required a regular resteering of the TL implying a non negligible amount of time spent for injection setup. Likely sources of instability have been identified (i.e. MKE and MSE ripples) and possible cures to optimise 2012 operation are presented. Well defined references for TL steering will be defined in a more rigorous way in order to allow a more straightforward and faster injection setup. Encountered and potential issues of the injection system, in particular the injection kickers MKI, are discussed also in view of injections with a higher number of bunches.

  8. Adalimumab Injection

    Science.gov (United States)

    ... the armpits, groin, and anal area) in adults, uveitis (swelling and inflammation of different areas of the ... certain lab tests before, during, and after your treatment to check your body's response to adalimumab.Do ...

  9. Persistent negative illness perceptions despite long-term biochemical control of acromegaly: novel application of the drawing test.

    Science.gov (United States)

    Tiemensma, Jitske; Pereira, Alberto M; Romijn, Johannes A; Broadbent, Elizabeth; Biermasz, Nienke R; Kaptein, Adrian A

    2015-05-01

    Patients with acromegaly have persistent complaints despite long-term biochemical control. Drawings can be used to assess patients' perceptions about their disease. We aimed to explore the utility of the drawing test and its relation to illness perceptions and quality of life (QoL) in patients after long-term remission of acromegaly. A cross-sectional study was conducted to evaluate the utility of the drawing test. A total of 50 patients after long-term remission (mean±s.e.m., 16±1.2 years) of acromegaly were included in this study. Patients completed the drawing test (two retrospective drawings of their body perception before acromegaly and during the active phase of acromegaly, and one drawing on the current condition after long-term remission), Illness Perception Questionnaire-Revised, Physical Symptom Checklist, EuroQoL-5D, and AcroQoL. Patients perceived a dramatic change in body size during the active state of the disease compared with the healthy state before the awareness of acromegaly. Patients reported that their body did not completely return to the original proportions after long-term remission. In addition, larger drawings indicated more negative consequences (Pdrawings also indicated more impaired QoL, especially disease-specific QoL (all Pdrawing test, illness perceptions, and QoL. The drawing test appears to be a novel and relatively easy tool to assess the perception of patients after long-term remission of acromegaly. The assessment of drawings may enable health care providers to appreciate the perceptions of patients with long-term remission of acromegaly, and enable discussion of symptoms and remission. © 2015 European Society of Endocrinology.

  10. EDF plan for a dispersant injection trial

    International Nuclear Information System (INIS)

    Mercier, Stephane; Corredera, Geraldine; Alves-Vieira, Maria; Mansour, Carine; You, Dominique

    2012-09-01

    In its strategy for SG fouling control, EDF is considering the use of dispersant as a preventive remedy. A trial on Golfech 2 started in May 2012. The dispersant selected for the trial is Polyacrylic Acid (PAA). The main goals of the test are to check and quantify the gain on iron transport to blowdown, to evaluate the possible effects on secondary side chemistry and the operational costs of the injection - reactant, ion exchange resins and filters. The results of the test, if satisfying, will be used to set EDF strategy for dispersant long term use on its fleet. So, one concern about the trial is to make sure that the conclusions of this test will be applicable to a wide range of EDF plants. For that purpose, several criteria have been examined for the choice of the candidate plant such as fouling level, secondary circuit materials (presence or absence of copper alloys,...), SG tube material, thermal power margin, secondary side chemistry (amine used and pH applied). Before starting the trial, EDF had to take into account the international feedback and to adapt it to its specific requirements: the neutralization amine was switched from ETA to morpholine, additional work had been completed to validate the innocuousness of PAA injection for EDF plants... This work especially includes laboratory testing of secondary side corrosion cracking in the presence of PAA and water chemistries used in EdF plants. Moreover, investigation on the thermal stability of PAA and degradation products was completed and further evaluation of environmental impact was performed. A dedicated skid for the injection of PAA was implemented in Golfech Chemicals injection room. The installation and the process were notably designed to take into account the high viscosity of the commercial product, and the need to proceed to a good rinsing of the pipes without increasing the discharged effluents. The first available data from Golfech 2 trial are also provided and discussed. (authors)

  11. Annual Report RCRA Post-Closure Monitoring and Inspections for Corrective Action Unit 91: Area 3 U-3fi Injection Well, Nevada Test Site, Nevada, for the Period October 2001 - October 2002

    International Nuclear Information System (INIS)

    Richardson, G.

    2003-01-01

    This annual monitoring and inspection report provides an analysis and summary for site inspections, meteorological information, and neutron soil moisture monitoring data obtained at the U-3fi Injection Well during the October 2001 to October 2002 period. The U-3fi Injection Well is located in Area 3 of the Nevada Test Site (NTS), Nye County, Nevada. Inspections of the Area 3 U-3fi Injection Well are conducted to determine and document the physical condition of the concrete pad, facilities, and any unusual conditions that could impact the proper operation of the waste disposal unit closure. The objective of the neutron logging is to monitor the soil moisture conditions along the 128-meter (m) (420-feet [ft]) ER3-3 monitoring well and detect changes that may be indicative of moisture movement in the regulated interval extending between 73 to 82 m (240 to 270 ft)

  12. Long term deactivation test of high dust SCR catalysts by straw co-firing

    Energy Technology Data Exchange (ETDEWEB)

    Weigang Lin; Degn Jensen, A.; Bjerkvig, J.

    2009-12-15

    The consequences of carbon dioxide induced global warming cause major concern worldwide. The consumption of energy produced with fossil fuels is the major factor that contributes to the global warming. Biomass is a renewable energy resource and has a nature of CO{sub 2} neutrality. Co-combustion of biomass in existing coal fired power plants can maintain high efficiency and reduce the emission of CO{sub 2} at same time. However, one of the problems faced by co-firing is deactivation of the SCR catalysts. Understanding of the mechanisms of deactivation of the catalyst elements at co-firing conditions is crucial for long term runs of the power plants. Twenty six SCR catalyst elements were exposed at two units (SSV3 and SSV4) in the Studstrup Power Plant for a long period. Both units co-fire coal and straw with a typical fraction of 8-10% straw on an energy basis during co-firing. SSV4 unit operated in co-firing mode most of the time; SSV3 unit co-fired straw half of the operating time. The main objective of this PSO-project is to gain knowledge of a long term influence on catalyst activity when co-firing straw in coal-fired power plants, thus, to improve the basis for operating the SCR-plants for NO{sub x}-reduction. The exposure time of the applied catalyst elements (HTAS and BASF) varied from approximately 5000 to 19000 hours in the power plant by exchanging the element two times. The activity of all elements was measured before and after exposure in a bench scale test rig at the Department of Chemical and Biochemical Engineering, Technical University of Denmark. The results show that the activity, estimated by exclusion of channel clogging of the elements, decreases gradually with the total exposure time. It appears that the exposure time under co-firing condition has little effect on the deactivation of the catalyst elements and no sharp decrease of the activity was observed. The average deactivation rate of the catalyst elements is 1.6 %/1000 hours. SEM

  13. Wireless fetal heart rate monitoring in inpatient full-term pregnant women: testing functionality and acceptability.

    Science.gov (United States)

    Boatin, Adeline A; Wylie, Blair; Goldfarb, Ilona; Azevedo, Robin; Pittel, Elena; Ng, Courtney; Haberer, Jessica

    2015-01-01

    We tested functionality and acceptability of a wireless fetal monitoring prototype technology in pregnant women in an inpatient labor unit in the United States. Women with full-term singleton pregnancies and no evidence of active labor were asked to wear the prototype technology for 30 minutes. We assessed functionality by evaluating the ability to successfully monitor the fetal heartbeat for 30 minutes, transmit this data to Cloud storage and view the data on a web portal. Three obstetricians also rated fetal cardiotocographs on ease of readability. We assessed acceptability by administering closed and open-ended questions on perceived utility and likeability to pregnant women and clinicians interacting with the prototype technology. Thirty-two women were enrolled, 28 of whom (87.5%) successfully completed 30 minutes of fetal monitoring including transmission of cardiotocographs to the web portal. Four sessions though completed, were not successfully uploaded to the Cloud storage. Six non-study clinicians interacted with the prototype technology. The primary technical problem observed was a delay in data transmission between the prototype and the web portal, which ranged from 2 to 209 minutes. Delays were ascribed to Wi-Fi connectivity problems. Recorded cardiotocographs received a mean score of 4.2/5 (± 1.0) on ease of readability with an interclass correlation of 0.81(95%CI 0.45, 0.96). Both pregnant women and clinicians found the prototype technology likable (81.3% and 66.7% respectively), useful (96.9% and 66.7% respectively), and would either use it again or recommend its use to another pregnant woman (77.4% and 66.7% respectively). In this pilot study we found that this wireless fetal monitoring prototype technology has potential for use in a United States inpatient setting but would benefit from some technology changes. We found it to be acceptable to both pregnant women and clinicians. Further research is needed to assess feasibility of using this

  14. Wireless fetal heart rate monitoring in inpatient full-term pregnant women: testing functionality and acceptability.

    Directory of Open Access Journals (Sweden)

    Adeline A Boatin

    Full Text Available We tested functionality and acceptability of a wireless fetal monitoring prototype technology in pregnant women in an inpatient labor unit in the United States. Women with full-term singleton pregnancies and no evidence of active labor were asked to wear the prototype technology for 30 minutes. We assessed functionality by evaluating the ability to successfully monitor the fetal heartbeat for 30 minutes, transmit this data to Cloud storage and view the data on a web portal. Three obstetricians also rated fetal cardiotocographs on ease of readability. We assessed acceptability by administering closed and open-ended questions on perceived utility and likeability to pregnant women and clinicians interacting with the prototype technology. Thirty-two women were enrolled, 28 of whom (87.5% successfully completed 30 minutes of fetal monitoring including transmission of cardiotocographs to the web portal. Four sessions though completed, were not successfully uploaded to the Cloud storage. Six non-study clinicians interacted with the prototype technology. The primary technical problem observed was a delay in data transmission between the prototype and the web portal, which ranged from 2 to 209 minutes. Delays were ascribed to Wi-Fi connectivity problems. Recorded cardiotocographs received a mean score of 4.2/5 (± 1.0 on ease of readability with an interclass correlation of 0.81(95%CI 0.45, 0.96. Both pregnant women and clinicians found the prototype technology likable (81.3% and 66.7% respectively, useful (96.9% and 66.7% respectively, and would either use it again or recommend its use to another pregnant woman (77.4% and 66.7% respectively. In this pilot study we found that this wireless fetal monitoring prototype technology has potential for use in a United States inpatient setting but would benefit from some technology changes. We found it to be acceptable to both pregnant women and clinicians. Further research is needed to assess feasibility of

  15. Analysis of linear and cyclic oligomers in polyamide-6 without sample preparation by liquid chromatography using the sandwich injection method. II. Methods of detection and quantification and overall long-term performance.

    Science.gov (United States)

    Mengerink, Y; Peters, R; Kerkhoff, M; Hellenbrand, J; Omloo, H; Andrien, J; Vestjens, M; van der Wal, S

    2000-05-05

    By separating the first six linear and cyclic oligomers of polyamide-6 on a reversed-phase high-performance liquid chromatographic system after sandwich injection, quantitative determination of these oligomers becomes feasible. Low-wavelength UV detection of the different oligomers and selective post-column reaction detection of the linear oligomers with o-phthalic dicarboxaldehyde (OPA) and 3-mercaptopropionic acid (3-MPA) are discussed. A general methodology for quantification of oligomers in polymers was developed. It is demonstrated that the empirically determined group-equivalent absorption coefficients and quench factors are a convenient way of quantifying linear and cyclic oligomers of nylon-6. The overall long-term performance of the method was studied by monitoring a reference sample and the calibration factors of the linear and cyclic oligomers.

  16. Evaluation of the Non-Transient Hydrologic Source Term from the CAMBRIC Underground Nuclear Test in Frenchman Flat, Nevada Test Site

    International Nuclear Information System (INIS)

    Tompson, A B; Maxwell, R M; Carle, S F; Zavarin, M; Pawloski, G A.; Shumaker, D E

    2005-01-01

    Hydrologic Source Term (HST) calculations completed in 1998 at the CAMBRIC underground nuclear test site were LLNL's first attempt to simulate a hydrologic source term at the NTS by linking groundwater flow and transport modeling with geochemical modeling (Tompson et al., 1999). Significant effort was applied to develop a framework that modeled in detail the flow regime and captured all appropriate chemical processes that occurred over time. However, portions of the calculations were simplified because of data limitations and a perceived need for generalization of the results. For example: (1) Transient effects arising from a 16 years of pumping at the site for a radionuclide migration study were not incorporated. (2) Radionuclide fluxes across the water table, as derived from infiltration from a ditch to which pumping effluent was discharged, were not addressed. (3) Hydrothermal effects arising from residual heat of the test were not considered. (4) Background data on the ambient groundwater flow direction were uncertain and not represented. (5) Unclassified information on the Radiologic Source Term (RST) inventory, as tabulated recently by Bowen et al. (2001), was unavailable; instead, only a limited set of derived data were available (see Tompson et al., 1999). (6) Only a small number of radionuclides and geochemical reactions were incorporated in the work. (7) Data and interpretation of the RNM-2S multiple well aquifer test (MWAT) were not available. As a result, the current Transient CAMBRIC Hydrologic Source Term project was initiated as part of a broader Phase 2 Frenchman Flat CAU flow and transport modeling effort. The source term will be calculated under two scenarios: (1) A more specific representation of the transient flow and radionuclide release behavior at the site, reflecting the influence of the background hydraulic gradient, residual test heat, pumping experiment, and ditch recharge, and taking into account improved data sources and modeling

  17. Water injection profiling

    International Nuclear Information System (INIS)

    Arnold, D.M.

    1982-01-01

    A method of neutron-gamma logging is described, in which water, injected in a cased well borehole with peforations, is irradiated with neutrons of 10 MeV or greater, and subsequent gamma radiation is detected by a pair of detectors along the borehole. Counting rates of detectors are analyzed in terms of two gamma ray energy windows. Linear flow velocity of fluid moving downward within the casing is used in conjunction with count rate data to determine volume flow rates of water moving in other directions. Apparatus includes a sonde with a neutron source and appropriate gamma sensors

  18. Safe injection procedures, injection practices, and needlestick ...

    African Journals Online (AJOL)

    Nermine Mohamed Tawfik Foda

    2017-01-10

    Jan 10, 2017 ... sures regarding disposable injection equipment, waste containers, hand hygiene ... injection practices lead to high prevalence of NSSIs in operating rooms. .... guidelines, the availability of training courses to HCWs, and provi-.

  19. Risk of sensitization in healthy adults following repeated administration of rdESAT-6 skin test reagent by the Mantoux injection technique

    DEFF Research Database (Denmark)

    Lillebaek, Troels; Bergstedt, Winnie; Tingskov, Pernille N

    2009-01-01

    1 open clinical trial was to assess the sensitization risk and safety of repeated administration of rdESAT-6 reagent in 31 healthy adult volunteers. Three groups of volunteers received two fixed doses of 0.1 microg rdESAT-6 28, 56 or 112 days apart, respectively. After the second injection...... of 31 (3%) volunteers showed a positive skin reaction (sensitization) upon a second injection of rdESAT-6 after 28days and an increased IFN-gamma response to ESAT-6. For 7 (23%) of the volunteers, local adverse reactions related to the product were registered, but all reactions were mild and predictable...

  20. Evaluation of upward migration around a deep injection well

    International Nuclear Information System (INIS)

    Chia, Yeeping; Chiu, J.

    1994-01-01

    The long-term containment of injected wastes in the deep subsurface is expected to be achieved under suitable geologic and hydrologic conditions and by the use of competent engineering practices. Field experiences, however, indicate that waste containment may be affected by hydrologic conduits around the injection well. To assess the potential effects of these conduits, upward migration of injected waste is examined through the use of numerical models under various conditions. Test results indicate that without any preferential hydrologic conduits, most of the injected waste moves laterally in the injection interval, whereas only a small amount of waste migrates upward into the containment interval. When vertical fractures in the disturbed zone or defects in the cement seal around the wellbore exist, the contaminant can move rapidly upward along these conduits to an overlying aquifer, from which it migrates in the lateral direction. The contamination of the overlying aquifer that results from the upward migration of injected waste through these conduits cannot be impeded by a thick, low-permeability containment interval. However, when permeable interbeds exist within the containment interval, a significant portion of the waste migrating upward can be diverted laterally before reaching the overlying aquifer. The front of built-up pressure can reach the aquifer or permeable interbed immediately overlying the injection interval through the preferential hydrologic conduits shortly after the injection starts, but it cannot move farther upward because of pressure dissipation in the permeable formation. This study suggests that the injected waste has the potential to migrate upward into overlying formations through preferential migration conduits around the wellbore

  1. Simulation of a Potential CO2 Storage in the West Paris Basin: Site Characterization and Assessment of the Long-Term Hydrodynamical and Geochemical Impacts Induced by the CO2 Injection

    Directory of Open Access Journals (Sweden)

    Estublier Audrey

    2017-07-01

    Full Text Available This article presents the preliminary results of a study carried out as part of a demonstration project of CO2 storage in the Paris Basin. This project funded by ADEME (French Environment and Energy Management Agency and several industrial partners (TOTAL, ENGIE, EDF, Lafarge, Air Liquide, Vallourec aimed to study the possibility to set up an experimental infrastructure of CO2 transport and storage. Regarding the storage, the objectives were: (1 to characterize the selected site by optimizing the number of wells in a CO2 injection case of 200 Mt over 50 years in the Trias, (2 to simulate over time the CO2 migration and the induced pressure field, and (3 to analyze the geochemical behavior of the rock over the long term (1,000 years. The preliminary site characterization study revealed that only the southern area of Keuper succeeds to satisfy this injection criterion using only four injectors. However, a complementary study based on a refined fluid flow model with additional secondary faults concluded that this zone presents the highest potential of CO2 injection but without reaching the objective of 200 Mt with a reasonable number of wells. The simulation of the base scenario, carried out before the model refinement, showed that the overpressure above 0.1 MPa covers an area of 51,869 km2 in the Chaunoy formation, 1,000 years after the end of the injection, which corresponds to the whole West Paris Basin, whereas the CO2 plume extension remains small (524 km2. This overpressure causes brine flows at the domain boundaries and a local overpressure in the studied oil fields. Regarding the preliminary risk analysis of this project, the geochemical effects induced by the CO2 injection were studied by simulating the fluid-rock interactions with a coupled geochemical and fluid flow model in a domain limited to the storage complex. A one-way coupling of two models based on two domains fitting into each other was developed using dynamic boundary

  2. Simulation of ultra-long term behavior in HLW near-field by centrifugal model test. Part 1. Development of centrifugal equipment and centrifuge model test method

    International Nuclear Information System (INIS)

    Nishimoto, Soshi; Okada, Tetsuji; Sawada, Masataka

    2011-01-01

    The objective of this paper is to develop a centrifugal equipment which can continuously be run for a long time and a model test method in order to evaluate a long term behavior which is a coupled thermo-hydro-mechanical processes in the high level wastes geological disposal repository and the neighborhood (called 'near-field'). The centrifugal equipment of CRIEPI, 'CENTURY5000-THM', developed in the present study is able to run continuously up to six months. Therefore, a long term behavior in the near-field can be simulated in a short term, for instance, the behavior for 5000 equivalent years can be simulated in six months by centrifugalizing 100 G using a 1/100 size model. We carried out a test using a nylon specimen in a centrifugal force field of 30 G and confirmed the operations of CENTURY5000-THM, control and measurement for 11 days. As the results, it was able to control the stress in the pressure vessel and measure the values of strain, temperature and pressure. And, as a result of scanning the small model of near-field including the metal overpack, bentonite buffer and rock by a medical X-rays CT scanner, the internal structure of the model was able to be evaluated when the metal artifact was reduced. From these results, the evaluation for a long term behavior of a disposal repository by the method of centrifugal model test became possible. (author)

  3. Experimental Testing of Monopiles in Sand Subjected to One-Way Long-Term Cyclic Lateral Loading

    DEFF Research Database (Denmark)

    Roesen, Hanne Ravn; Ibsen, Lars Bo; Andersen, Lars Vabbersgaard

    2013-01-01

    In the offshore wind turbine industry the most widely used foundation type is the monopile. Due to the wave and wind forces the monopile is subjected to a strong cyclic loading with varying amplitude, maximum loading level, and varying loading period. In this paper the soil–pile interaction...... of a monopile in sand subjected to a long-term cyclic lateral loading is investigated by means of small scale tests. The tests are conducted with a mechanical loading rig capable of applying the cyclic loading as a sine signal with varying amplitude, mean loading level, and loading period for more than 60 000...... cycles. The tests are conducted in dense saturated sand. The maximum moment applied in the cyclic tests is varied from 18% to 36% of the ultimate lateral resistance found in a static loading test. The tests reveal that the accumulated rotation can be expressed by use of a power function. Further, static...

  4. Usefulness of a 50-meter round walking test for fall prediction in the elderly requiring long-term care

    Science.gov (United States)

    Hachiya, Mizuki; Murata, Shin; Otao, Hiroshi; Ihara, Takehiko; Mizota, Katsuhiko; Asami, Toyoko

    2015-01-01

    [Purpose] This study aimed to verify the usefulness of a 50-m round walking test developed as an assessment method for walking ability in the elderly. [Subjects] The subjects were 166 elderly requiring long-term care individuals (mean age, 80.5 years). [Methods] In order to evaluate the factors that had affected falls in the subjects in the previous year, we performed the 50-m round walking test, functional reach test, one-leg standing test, and 5-m walking test and measured grip strength and quadriceps strength. [Results] The 50-m round walking test was selected as a variable indicating fall risk based on the results of multiple logistic regression analysis. The cutoff value of the 50-m round walking test for determining fall risk was 0.66 m/sec. The area under the receiver operating characteristic curve was 0.64. The sensitivity of the cutoff value was 65.7%, the specificity was 63.6%, the positive predictive value was 55.0%, the negative predictive value was 73.3%, and the accuracy was 64.5%. [Conclusion] These results suggest that the 50-m round walking test is a potentially useful parameter for the determination of fall risk in the elderly requiring long-term care. PMID:26834327

  5. Evaluation of the E mu-pim-1 transgenic mouse model for short-term carcinogenicity testing

    DEFF Research Database (Denmark)

    van Kreijl, C. F.; van Oordt, C. W. V.; Kroese, E. D.

    1998-01-01

    of T-cell lymphomas. Because of the low incidence of spontaneous tumors and the increased sensitivity to N-ethyl-N-nitrosourea-induced carcinogenesis, E mu-pim-1 mice were suggested to be one of the first potential and attractive candidates to be used in short-term carcinogenicity testing...

  6. Persistent negative illness perceptions despite long-term biochemical control of acromegaly: novel application of the drawing test

    NARCIS (Netherlands)

    Tiemensma, Jitske; Pereira, Alberto M.; Romijn, Johannes A.; Broadbent, Elizabeth; Biermasz, Nienke R.; Kaptein, Adrian A.

    2015-01-01

    Context and objective: Patients with acromegaly have persistent complaints despite long-term biochemical control. Drawings can be used to assess patients' perceptions about their disease. We aimed to explore the utility of the drawing test and its relation to illness perceptions and quality of life

  7. An Asset Pricing Approach to Testing General Term Structure Models including Heath-Jarrow-Morton Specifications and Affine Subclasses

    DEFF Research Database (Denmark)

    Christensen, Bent Jesper; van der Wel, Michel

    of the risk premium is associated with the slope factor, and individual risk prices depend on own past values, factor realizations, and past values of other risk prices, and are significantly related to the output gap, consumption, and the equity risk price. The absence of arbitrage opportunities is strongly...... is tested, but in addition to the standard bilinear term in factor loadings and market prices of risk, the relevant mean restriction in the term structure case involves an additional nonlinear (quadratic) term in factor loadings. We estimate our general model using likelihood-based dynamic factor model...... techniques for a variety of volatility factors, and implement the relevant likelihood ratio tests. Our factor model estimates are similar across a general state space implementation and an alternative robust two-step principal components approach. The evidence favors time-varying market prices of risk. Most...

  8. Long-term dose-response studies of inhaled or injected radionuclides. Biennial report, 1 October 1991--30 September 1993

    Energy Technology Data Exchange (ETDEWEB)

    Boecker, B.B.; Muggenburg, B.A.; Miller, S.C.; Bradley, P.L. [eds.

    1994-01-01

    This report describes the scientific progress in, and current status of, life-span studies of the long-term health risks in Beagle dogs of chronic irradiation from internally deposited radionuclides or from an external source. The reporting period for this document is the 2-year period from October 1, 1991 through September 30, 1993. Studies that were initiated at three different laboratories (Inhalation Toxicology Research Institute, ITRI, University of Utah, and Argonne National Laboratory, ANL) are presented here because they are being completed at ITRI. All living dogs in the Utah-initiated studies were transferred to the ITRI facility for the remainder of their life-span observations and measurements in September 1987. This report is the fourth in a series of reports dealing with the current status and progress of both the Utah and ITRI studies. Other life-span studies involving dogs exposed to gamma radiation from an external source were initiated and conducted for many years at ANL. In 1991, the decision was made to discontinue the chronic irradiation of the remaining living dogs and to transfer all remaining dogs to ITRI for care, clinical observations, and pathological observations at death or euthanasia. This report provides the current status of these dogs. Status reports on the Utah and ITRI studies comprise most of this report. The ITRI-related section presents brief statements of project objectives, the general procedures used in these studies, and some study-specific features for each of the 19 studies being conducted with either beta- or alpha-emitting radionuclides. Dose- and effect-modifying factors being addressed in these studies include total dose, dose rate, LET, solubility, nonuniformity of dose, species, age, sex, health status, and mode of exposure. Recent additions to experimental protocols for studies in which dogs are still alive involve the collection and analysis of tumor tissues using currently available molecular biology techniques.

  9. Penicillin G Procaine Injection

    Science.gov (United States)

    Penicillin G procaine injection is used to treat certain infections caused by bacteria. Penicillin G procaine injection should not be used to ... early in the treatment of certain serious infections. Penicillin G procaine injection is in a class of ...

  10. Genetic testing for BRCA1: effects of a randomised study of knowledge provision on interest in testing and long term test uptake; implications for the NICE guidelines.

    Science.gov (United States)

    Hall, Julia; Gray, Susan; A'Hern, Roger; Shanley, Susan; Watson, Maggie; Kash, Kathryn; Croyle, Robert; Eeles, Rosalind

    2009-01-01

    Interest in searching for mutations in BRCA1 and BRCA2 is high. Knowledge regarding these genes and the advantages and limitations of genetic testing is limited. It is unknown whether increasing knowledge about breast cancer genetic testing alters interest in testing. Three hundred and seventy nine women (260 with a family history of breast cancer; 119 with breast cancer) from The Royal Marsden NHS Foundation Trust were randomised to receive or not receive written educational information on cancer genetics. A questionnaire was completed assessing interest in BRCA1 testing and knowledge on breast cancer genetics and screening. Actual uptake of BRCA1 testing is reported with a six year follow-up. Eighty nine percent of women at risk of breast cancer and 76% of women with breast cancer were interested in BRCA1 testing (P testing, the families of 66% of the at risk group and 13% of the women with breast cancer would be eligible for testing (probability of BRCA1 mutation >or=20%). Within six years of randomisation, genetic testing was actually undertaken on 12 women, only 10 of whom would now be eligible, on the NICE guidelines. There is strong interest in BRCA1 testing. Despite considerable ignorance of factors affecting the inheritance of breast cancer, education neither reduced nor increased interest to undergo testing. The NICE guidelines successfully triage those with a high breast cancer risk to be managed in cancer genetics clinics.

  11. An automatic sodium-loop for testing the lon-term behaviour of sintered bodies flowed through by gas

    International Nuclear Information System (INIS)

    Barkleit, G.; George, G.; Haase, I.; Kiessling, W.

    1980-08-01

    An automatic sodium loop NAKOS for testing the long-term behaviour of porous stainless steel bodies which are flowed through by gas is described. The loop using a special safety protection system is capable of working without control up to 1000 h. During a 500 h-experiment the safety system and the gas permeability measuring method for testing the porous bodies were tested. Both first results of the behaviour of sintered bodies in liquid sodium of high purity and temperatures of about 850 K and some details of the production of these bodies are given. (author)

  12. 76 FR 22608 - Third Party Testing for Certain Children's Products; Clothing Textiles: Revisions to Terms of...

    Science.gov (United States)

    2011-04-22

    ... Product Certifications Based on Third Party Conformity Assessment Body Testing Prior to Commission's... the product. The Commission also emphasizes that, irrespective of certification, the product in... lifting the stay of enforcement with regard to testing and certification of children's products under 16...

  13. Comparison of short-term estrogenicity tests for identification of hormone-disrupting chemicals

    DEFF Research Database (Denmark)

    Andersen, H R; Andersson, A M; Arnold, S F

    1999-01-01

    induced a strong estrogenic response in all test systems. Colchicine caused cytotoxicity only. Bisphenol A induced an estrogenic response in all assays. The results obtained for the remaining test compounds--tamoxifen, ICI 182.780, testosterone, bisphenol A dimethacrylate, 4-n-octylphenol, 4-n...

  14. Short-term practice effects and variability in cognitive testing in a healthy elderly population

    DEFF Research Database (Denmark)

    Krenk, L.; Rasmussen, L.S.; Siersma, V.

    2012-01-01

    BACKGROUND: Cognitive decline in the elderly is a subject of intense focus. However, there is a lack of consensus regarding definition of significant decline in connection with repeated testing and the interpretation of cognitive tests results must take into account the practice effect...

  15. Short-term delayed recall of auditory verbal learning test is equivalent to long-term delayed recall for identifying amnestic mild cognitive impairment.

    Directory of Open Access Journals (Sweden)

    Qianhua Zhao

    Full Text Available Delayed recall of words in a verbal learning test is a sensitive measure for the diagnosis of amnestic mild cognitive impairment (aMCI and early Alzheimer's disease (AD. The relative validity of different retention intervals of delayed recall has not been well characterized. Using the Auditory Verbal Learning Test-Huashan version, we compared the differentiating value of short-term delayed recall (AVL-SR, that is, a 3- to 5-minute delay time and long-term delayed recall (AVL-LR, that is, a 20-minute delay time in distinguishing patients with aMCI (n = 897 and mild AD (n = 530 from the healthy elderly (n = 1215. In patients with aMCI, the correlation between AVL-SR and AVL-LR was very high (r = 0.94, and the difference between the two indicators was less than 0.5 points. There was no difference between AVL-SR and AVL-LR in the frequency of zero scores. In the receiver operating characteristic curves analysis, although the area under the curve (AUC of AVL-SR and AVL-LR for diagnosing aMCI was significantly different, the cut-off scores of the two indicators were identical. In the subgroup of ages 80 to 89, the AUC of the two indicators showed no significant difference. Therefore, we concluded that AVL-SR could substitute for AVL-LR in identifying aMCI, especially for the oldest patients.

  16. The capital-asset pricing model reconsidered: tests in real terms on ...

    African Journals Online (AJOL)

    This paper extends previous work of the authors to reconsider the capital-asset pricing model (CAPM) in South Africa in real terms. As in that work, the main question this study aimed to answer remains: Can the CAPM be accepted in the South African market for the purposes of the stochastic modelling of investment returns ...

  17. Comparison of Short-Term Estrogenicity Tests for Identification of Hormone-Disrupting Chemicals

    DEFF Research Database (Denmark)

    Andersen, Helle Raun; Andersson, Anna-Maria; Arnold, Steven F.

    1999-01-01

    The aim of this study was to compare results obtained by eight different short-term assays of estrogenlike actions of chemicals conducted in 10 different laboratories in five countries. Twenty chemicals were selected to represent direct-acting estrogens, compounds with estrogenic metabolites, est...

  18. Comparison of short-term estrogenicity tests for identification of hormone-disrupting chemicals

    DEFF Research Database (Denmark)

    Andersen, H R; Andersson, A M; Arnold, S F

    1999-01-01

    The aim of this study was to compare results obtained by eight different short-term assays of estrogenlike actions of chemicals conducted in 10 different laboratories in five countries. Twenty chemicals were selected to represent direct-acting estrogens, compounds with estrogenic metabolites, est...

  19. A contoured gap coaxial plasma gun with injected plasma armature

    Energy Technology Data Exchange (ETDEWEB)

    Witherspoon, F. Douglas; Case, Andrew; Messer, Sarah J.; Bomgardner, Richard II; Phillips, Michael W.; Brockington, Samuel; Elton, Raymond [HyperV Technologies Corp., Chantilly, Virginia 20151 (United States)

    2009-08-15

    A new coaxial plasma gun is described. The long term objective is to accelerate 100-200 {mu}g of plasma with density above 10{sup 17} cm{sup -3} to greater than 200 km/s with a Mach number above 10. Such high velocity dense plasma jets have a number of potential fusion applications, including plasma refueling, magnetized target fusion, injection of angular momentum into centrifugally confined mirrors, high energy density plasmas, and others. The approach uses symmetric injection of high density plasma into a coaxial electromagnetic accelerator having an annular gap geometry tailored to prevent formation of the blow-by instability. The injected plasma is generated by numerous (currently 32) radially oriented capillary discharges arranged uniformly around the circumference of the angled annular injection region of the accelerator. Magnetohydrodynamic modeling identified electrode profiles that can achieve the desired plasma jet parameters. The experimental hardware is described along with initial experimental results in which approximately 200 {mu}g has been accelerated to 100 km/s in a half-scale prototype gun. Initial observations of 64 merging injector jets in a planar cylindrical testing array are presented. Density and velocity are presently limited by available peak current and injection sources. Steps to increase both the drive current and the injected plasma mass are described for next generation experiments.

  20. A contoured gap coaxial plasma gun with injected plasma armature.

    Science.gov (United States)

    Witherspoon, F Douglas; Case, Andrew; Messer, Sarah J; Bomgardner, Richard; Phillips, Michael W; Brockington, Samuel; Elton, Raymond

    2009-08-01

    A new coaxial plasma gun is described. The long term objective is to accelerate 100-200 microg of plasma with density above 10(17) cm(-3) to greater than 200 km/s with a Mach number above 10. Such high velocity dense plasma jets have a number of potential fusion applications, including plasma refueling, magnetized target fusion, injection of angular momentum into centrifugally confined mirrors, high energy density plasmas, and others. The approach uses symmetric injection of high density plasma into a coaxial electromagnetic accelerator having an annular gap geometry tailored to prevent formation of the blow-by instability. The injected plasma is generated by numerous (currently 32) radially oriented capillary discharges arranged uniformly around the circumference of the angled annular injection region of the accelerator. Magnetohydrodynamic modeling identified electrode profiles that can achieve the desired plasma jet parameters. The experimental hardware is described along with initial experimental results in which approximately 200 microg has been accelerated to 100 km/s in a half-scale prototype gun. Initial observations of 64 merging injector jets in a planar cylindrical testing array are presented. Density and velocity are presently limited by available peak current and injection sources. Steps to increase both the drive current and the injected plasma mass are described for next generation experiments.

  1. A contoured gap coaxial plasma gun with injected plasma armature

    International Nuclear Information System (INIS)

    Witherspoon, F. Douglas; Case, Andrew; Messer, Sarah J.; Bomgardner, Richard II; Phillips, Michael W.; Brockington, Samuel; Elton, Raymond

    2009-01-01

    A new coaxial plasma gun is described. The long term objective is to accelerate 100-200 μg of plasma with density above 10 17 cm -3 to greater than 200 km/s with a Mach number above 10. Such high velocity dense plasma jets have a number of potential fusion applications, including plasma refueling, magnetized target fusion, injection of angular momentum into centrifugally confined mirrors, high energy density plasmas, and others. The approach uses symmetric injection of high density plasma into a coaxial electromagnetic accelerator having an annular gap geometry tailored to prevent formation of the blow-by instability. The injected plasma is generated by numerous (currently 32) radially oriented capillary discharges arranged uniformly around the circumference of the angled annular injection region of the accelerator. Magnetohydrodynamic modeling identified electrode profiles that can achieve the desired plasma jet parameters. The experimental hardware is described along with initial experimental results in which approximately 200 μg has been accelerated to 100 km/s in a half-scale prototype gun. Initial observations of 64 merging injector jets in a planar cylindrical testing array are presented. Density and velocity are presently limited by available peak current and injection sources. Steps to increase both the drive current and the injected plasma mass are described for next generation experiments.

  2. Hydrogen pellet injection device

    International Nuclear Information System (INIS)

    Kanno, Masahiro.

    1992-01-01

    In a hydrogen pellet injection device, a nozzle block having a hydrogen gas supply channel is disposed at the inner side of a main cryogenic housing, and an electric resistor is attached to the block. Further, a nozzle block and a hydrogen gas introduction pipe are attached by way of a thermal insulating spacer. Electric current is supplied to the resistor to positively heat the nozzle block and melt remaining solid hydrogen in the hydrogen gas supply channel. Further, the effect of temperature elevation due to the resistor is prevented from reaching the side of the hydrogen gas introduction pipe by the thermal insulation spacer. That is, the temperature of the nozzle block is directly and positively elevated, to melt the solid hydrogen rapidly. Preparation operation from the injection of the hydrogen pellet to the next injection can be completed in a shorter period of time compared with a conventional case thereby enabling to make the test more efficient. Further, only the temperature of the nozzle block is elevated with no effect of temperature elevation due to the resistor to other components by the thermal insulation flange. (N.H.)

  3. Comparison of accelerated pavement test results with long term pavement behaviour and performance

    CSIR Research Space (South Africa)

    Jooste, FJ

    1997-08-01

    Full Text Available The aim of this study was to investigate the following:how accelerated pavement testing predictions compare with actual road behaviour and performance the relative influences of load and environmental factors on pavement deterioration and how well...

  4. Test setup for long term reliability investigation of Silicon Carbide MOSFETs

    DEFF Research Database (Denmark)

    Baker, Nick; Munk-Nielsen, Stig; Beczkowski, Szymon

    2013-01-01

    Silicon Carbide MOSFETs are now widely available and have frequently been demonstrated to offer numerous advantages over Silicon based devices. However, reliability issues remain a significant concern in their realisation in commercial power electronic systems. In this paper, a test bench...... is designed that enables an accelerated power cycling test to be performed on packaged Silicon Carbide MOSFETs (TO-247) under realistic operating conditions. An accelerated power cycling test is then performed, with on-state resistance selected as the observed parameter to detect degradation. On......-state resistance is routinely monitored online through the use of an innovative voltage measurement system. The packaged Silicon Carbide MOSFET is shown to exhibit a 25% increase in on-state resistance as the device ages throughout its lifetime, with the test still on-going....

  5. Calibration of full-scale accelerated pavement testing data using long-term pavement performance data

    CSIR Research Space (South Africa)

    VdM Steyn, WJ

    2012-09-01

    Full Text Available Accelerated Pavement Testing (APT) has always been conducted with the objective of improving the understanding of real pavements under real traffic and environmental conditions. While APT provides an accelerated view of some of the major structural...

  6. The Seasonal KPSS Test: Examining Possible Applications with Monthly Data and Additional Deterministic Terms

    Directory of Open Access Journals (Sweden)

    Ghassen El Montasser

    2015-05-01

    Full Text Available The literature has been notably less definitive in distinguishing between finite sample studies of seasonal stationarity than in seasonal unit root tests. Although the use of seasonal stationarity and unit root tests is advised to determine correctly the most appropriate form of the trend in a seasonal time series, such a use is rarely noted in the relevant studies on this topic. Recently, the seasonal KPSS test, with a null hypothesis of no seasonal unit roots, and based on quarterly data, has been introduced in the literature. The asymptotic theory of the seasonal KPSS test depends on whether data have been filtered by a preliminary regression. More specifically, one may proceed to extracting deterministic components, such as the mean and trend, from the data before testing. In this paper, we examine the effects of de-trending on the properties of the seasonal KPSS test in finite samples. A sketch of the test’s limit theory is subsequently provided. Moreover, a Monte Carlo study is conducted to analyze the behavior of the test for a monthly time series. The focus on this time-frequency is significant because, as we mentioned above, it was introduced for quarterly data. Overall, the results indicated that the seasonal KPSS test preserved its good size and power properties. Furthermore, our results corroborate those reported elsewhere in the literature for conventional stationarity tests. These subsequent results assumed that the nonparametric corrections of residual variances may lead to better in-sample properties of the seasonal KPSS test. Next, the seasonal KPSS test is applied to a monthly series of the United States (US consumer price index. We were able to identify a number of seasonal unit roots in this time series. [1] [1]    Table 1 in this paper is copyrighted and initially published by JMASM in 2012, Volume 11, Issue 1, pp. 69–77, ISSN: 1538–9472, JMASM Inc., PO Box 48023, Oak Park, MI 48237, USA, ea@jmasm.com.

  7. Long-Term and Short-Term Effects of Hemodialysis on Liver Function Evaluated Using the Galactose Single-Point Test

    Directory of Open Access Journals (Sweden)

    Yi-Chou Hou

    2014-01-01

    Full Text Available Aim. The galactose single-point (GSP test assesses functioning liver mass by measuring the galactose concentration in the blood 1 hour after its administration. The purpose of this study was to investigate the impact of hemodialysis (HD on short-term and long-term liver function by use of GSP test. Methods. Seventy-four patients on maintenance HD (46 males and 28 females, 60.38 ± 11.86 years with a mean time on HD of 60.77 ± 48.31 months were studied. The GSP values were compared in two groups: (1 before and after single session HD, and (2 after one year of maintenance HD. Results. Among the 74 HD patient, only the post-HD Cr levels and years on dialysis were significantly correlated with GSP values (r=0.280, P<0.05 and r=-0.240, P<0.05, resp.. 14 of 74 patients were selected for GSP evaluation before and after a single HD session, and the hepatic clearance of galactose was similar (pre-HD 410 ± 254 g/mL, post-HD 439 ± 298 g/mL, P=0.49. GSP values decreased from 420.20 ± 175.26 g/mL to 383.40 ± 153.97 g/mL after 1 year maintenance HD in other 15 patients (mean difference: 19.00 ± 37.66 g/mL, P<0.05. Conclusions. Patients on maintenance HD for several years may experience improvement of their liver function. However, a single HD session does not affect liver function significantly as assessed by the GSP test. Since the metabolism of galactose is dependent on liver blood flow and hepatic functional mass, further studies are needed.

  8. Use of short-term test systems for the prediction of the hazard represented by potential chemical carcinogens

    International Nuclear Information System (INIS)

    Glass, L.R.; Jones, T.D.; Easterly, C.E.; Walsh, P.J.

    1990-10-01

    It has been hypothesized that results from short-term bioassays will ultimately provide information that will be useful for human health hazard assessment. Historically, the validity of the short-term tests has been assessed using the framework of the epidemiologic/medical screens. In this context, the results of the carcinogen (long-term) bioassay is generally used as the standard. However, this approach is widely recognized as being biased and, because it employs qualitative data, cannot be used to assist in isolating those compounds which may represent a more significant toxicologic hazard than others. In contrast, the goal of this research is to address the problem of evaluating the utility of the short-term tests for hazard assessment using an alternative method of investigation. Chemicals were selected mostly from the list of carcinogens published by the International Agency for Research on Carcinogens (IARC); a few other chemicals commonly recognized as hazardous were included. Tumorigenicity and mutagenicity data on 52 chemicals were obtained from the Registry of Toxic Effects of Chemical Substances (RTECS) and were analyzed using a relative potency approach. The data were evaluated in a format which allowed for a comparison of the ranking of the mutagenic relative potencies of the compounds (as estimated using short-term data) vs. the ranking of the tumorigenic relative potencies (as estimated from the chronic bioassays). Although this was a preliminary investigation, it offers evidence that the short-term tests systems may be of utility in ranking the hazards represented by chemicals which may contribute to increased carcinogenesis in humans as a result of occupational or environmental exposures. 177 refs., 8 tabs

  9. Use of short-term test systems for the prediction of the hazard represented by potential chemical carcinogens

    Energy Technology Data Exchange (ETDEWEB)

    Glass, L.R.; Jones, T.D.; Easterly, C.E.; Walsh, P.J.

    1990-10-01

    It has been hypothesized that results from short-term bioassays will ultimately provide information that will be useful for human health hazard assessment. Historically, the validity of the short-term tests has been assessed using the framework of the epidemiologic/medical screens. In this context, the results of the carcinogen (long-term) bioassay is generally used as the standard. However, this approach is widely recognized as being biased and, because it employs qualitative data, cannot be used to assist in isolating those compounds which may represent a more significant toxicologic hazard than others. In contrast, the goal of this research is to address the problem of evaluating the utility of the short-term tests for hazard assessment using an alternative method of investigation. Chemicals were selected mostly from the list of carcinogens published by the International Agency for Research on Carcinogens (IARC); a few other chemicals commonly recognized as hazardous were included. Tumorigenicity and mutagenicity data on 52 chemicals were obtained from the Registry of Toxic Effects of Chemical Substances (RTECS) and were analyzed using a relative potency approach. The data were evaluated in a format which allowed for a comparison of the ranking of the mutagenic relative potencies of the compounds (as estimated using short-term data) vs. the ranking of the tumorigenic relative potencies (as estimated from the chronic bioassays). Although this was a preliminary investigation, it offers evidence that the short-term tests systems may be of utility in ranking the hazards represented by chemicals which may contribute to increased carcinogenesis in humans as a result of occupational or environmental exposures. 177 refs., 8 tabs.

  10. The design, fabrication, and testing of WETF high-quality, long-term-storage, secondary containment vessels

    International Nuclear Information System (INIS)

    Fisher, Kane J.

    2000-01-01

    Los Alamos National Laboratory's Weapons Engineering Tritium Facility (WETF) requires secondary containment vessels to store primary tritium containment vessels. The primary containment vessel provides the first boundary for tritium containment. The primary containment vessel is stored within a secondary containment vessel that provides the secondary boundary for tritium containment. WETF requires high-quality, long-term-storage, secondary tritium containment vessels that fit within a Mound-designed calorimeter. In order to qualify the WETF high-quality, long-term-storage, secondary containment vessels for use at WETF, steps have been taken to ensure the appropriate design, adequate testing, quality in fabrication, and acceptable documentation

  11. Systemic or Intra-Amygdala Injection of a Benzodiazepine (Midazolam) Impairs Extinction but Spares Re-Extinction of Conditioned Fear Responses

    Science.gov (United States)

    Hart, Genevra; Harris, Justin A.; Westbrook, R. Frederick

    2009-01-01

    Rats were subjected to one or two cycles of fear conditioning and extinction, injected with a benzodiazepine, midazolam, before the first or second extinction, and tested for long-term inhibition of fear responses (freezing). In Experiment 1, inhibition of context-conditioned fear was spared when midazolam was injected before the second…

  12. LOT Project long term test of buffer material at the Aespoe HRL

    International Nuclear Information System (INIS)

    Karnland, O.; Olsson, S.; Dueck, A.; Birgersson, M.; Nilsson, U.; Hernan-Haakansson, T.; Pedersen, K.; Eriksson, S.; Eriksen, T.; Eriksson, S.; Rosborg, B.; Muurinen, A.; Rousset, D.; Mosser-Ruck, R.; Cathelineau, M.; Villieras, F.; Pelletier, M.; Kaufold, S.; Dohrmann, R.; Fernandez, R.; Maeder, U.; Koroleva, M.

    2010-01-01

    Document available in extended abstract form only. Bentonite clay has been proposed as buffer material in several concepts for HLW repositories. The decaying spent fuel in the HLW canisters will increase temperature of the bentonite buffer. A number of laboratory test series, made by different research groups, have resulted in various bentonite alteration models. According to these models no significant alteration of the buffer is expected to take place at the prevailing physico-chemical conditions in the proposed Swedish KBS-3 repository, neither during, nor after water saturation. The ongoing LOT test series is focused on quantifying the mineralogical alteration in the buffer in a repository like environment at the Aespoe HRL. Further, buffer related processes concerning bacterial survival/activity, cation transport, and copper corrosion are studied. In total, the LOT test series includes seven test parcels, of which three are exposed to standard KBS-3 conditions and four test parcels are exposed to adverse conditions. Each test parcel contains a central Cu-tube surrounded by bentonite cylinder rings with a diameter of 30 cm, additional test material (Cu coupons, 60 Co tracers, bacteria etc) and instruments. Electrical heaters were place within the copper tube in order to simulate effect of decaying power from the spent fuel. The entire test parcels were released from the rock after the field exposure by overlapping boring and the bentonite material was analyzed with respect to: - physical properties (water content, density, swelling pressure, hydraulic conductivity, rheology); - mineralogical alteration in the bentonite; - distribution of added substances (e.g diffusional transport of 60 Co); - copper corrosion; - bacterial survival/activity. Two one year tests were started in 1996 and terminated in 1998. The results from tests and analyses are presented in SKB TR-00-22. The remaining four test parcels were installed during the fall 1999 plus one additional one

  13. Transverse injection into Mach 2 flow behind a rearward-facing step - A 3-D, compressible flow test case for hypersonic combustor CFD validation

    Science.gov (United States)

    Mcdaniel, James C.; Fletcher, Douglas G.; Hartfield, Roy J.; Hollo, Steven D.

    1991-01-01

    A spatially-complete data set of the important primitive flow variables is presented for the complex, nonreacting, 3D unit combustor flow field employing transverse injection into a Mach 2 flow behind a rearward-facing step. A unique wind tunnel facility providing the capability for iodine seeding was built specifically for these measurements. Two optical techniques based on laser-induced-iodine fluorescence were developed and utilized for nonintrusive, in situ flow field measurements. LDA provided both mean and fluctuating velocity component measurements. A thermographic phosphor wall temperature measurement technique was developed and employed. Data from the 2D flow over a rearward-facing step and the complex 3D mixing flow with injection are reported.

  14. Long-term pumping test in borehole KR24 flow measurements

    Energy Technology Data Exchange (ETDEWEB)

    Rouhiainen, P.; Poellaenen, J. [PRG-Tec Oy, Espoo (Finland)

    2005-09-15

    The Difference Flow method can be used for the relatively fast determination of transmissivity and hydraulic head in fractures or fractured zones in cored boreholes. In this study, the Difference Flow method was used for hydraulic crosshole interference tests. The tests were performed in boreholes KR24 (pumped borehole) KR4, KR7, KR8, KRlO, KR14, KR22, KR22B, KR26, KR27, KR27B, KR28 and KR28B at Olkiluoto during the first and second quarters of 2004. The distance between the boreholes varies from approximately tens of meters to hundreds of meters. All the measurements were carried out in open boreholes, i.e. no packers were used. For interpretation, a normal single hole test was first performed in each borehole. Flow rates and drawdown were first measured both without pumping and with pumping the borehole under test. For practical reasons, the data set is neither complete nor similar in all tested boreholes. Connected flow to borehole KR24 was detected in all these boreholes. These flow responses were concentrated on a few zones. (orig.)

  15. SQL Injection Defenses

    CERN Document Server

    Nystrom, Martin

    2007-01-01

    This Short Cut introduces you to how SQL injection vulnerabilities work, what makes applications vulnerable, and how to protect them. It helps you find your vulnerabilities with analysis and testing tools and describes simple approaches for fixing them in the most popular web-programming languages. This Short Cut also helps you protect your live applications by describing how to monitor for and block attacks before your data is stolen. Hacking is an increasingly criminal enterprise, and web applications are an attractive path to identity theft. If the applications you build, manage, or guar

  16. Long term leaching of silicate systems: testing procedure, actinides behaviour and mechanism

    International Nuclear Information System (INIS)

    Louwrier, K.; Matzke, H.; Ray, I.; Thiele, H.; Scheffler, K.; Riege, U.

    1977-06-01

    High-level waste borosilicate glasses and medium-level waste cement products have been leached with various aqueous solutions at ambient temperature. The leach rates of americium and plutonium are determined as well as the behaviour of the actinides in the boundary surface glass/leachant and in the leachant itself. Methods like light-scattering photometry and differential refractometry, molecular filtration, scanning electron microscopy and α-spectrometry of the energy-loss of α-particles in thin layers have been applied. From the experimental results a general model for the leaching mechanism has been established. A critical review of leach test procedures is accomplished aiming at the improvement of common tests with respect to the extrapolation of the obtained leach test data to final disposal safety considerations. (orig.) [de

  17. Routine blood tests are associated with short term mortality and can improve emergency department triage

    DEFF Research Database (Denmark)

    Kristensen, Michael; Iversen, Anne Kristine Servais; Gerds, Thomas Alexander

    2017-01-01

    BACKGROUND: Prioritization of acutely ill patients in the Emergency Department remains a challenge. We aimed to evaluate whether routine blood tests can predict mortality in unselected patients in an emergency department and to compare risk prediction with a formalized triage algorithm. METHODS...... registration. Multiple logistic regressions were used to predict 30-day mortality. Validation was performed by applying the regression models on the 2013 validation cohort. RESULTS: Thirty-day mortality was 5.3%. The routine blood tests had a significantly stronger discriminative value on 30-day mortality...... compared to the formalized triage (AUC 88.1 [85.7;90.5] vs. 63.4 [59.1;67.5], p blood tests was able to identify a larger number of low risk patients (n = 2100, 30-day mortality 0.1% [95% CI 0.0;0.3%]) compared to formalized triage (n = 1591, 2.8% [95% CI 2...

  18. Near-term electric test vehicle ETV-2. Phase II. Final report

    Energy Technology Data Exchange (ETDEWEB)

    1981-04-01

    A unique battery-powered passenger vehicle has been developed that provides a significant improvement over conventional electric vehicle performance, particularly during stop-and-go driving. The vehicle is unique in two major respects: (1) the power system incorporates a flywheel that stores energy during regenerative braking and makes possible the acceleration capability needed to keep up with traffic without reducing range to unacceptable values; and (2) lightweight plastic materials are used for the vehicle unibody to minimize weight and increase range. These features were analyzed and demonstrated in an electric test vehicle, ETV-2. Characteristics of this vehicle are summarized. Information is presented on: vehicle design, fabrication, safety testing, and performance testing; power system design and operation; flywheel; battery pack performance; and controls and electronic equipment. (LCL)

  19. Long-term water absorption tests for frost insulation materials taking into account frost attack

    Directory of Open Access Journals (Sweden)

    Toni A. Pakkala

    2014-01-01

    Full Text Available Water absorption of several different frost insulation materials was tested for four years. The test took into account both immersion and frost attack to materials. On the basis of the research the water absorption on XPS specimens is significantly minor compared to EPS specimens that were studied. The most significant result was that freezing of test specimens did not affect on water absorption of XPS specimens but had a major effect on water absorption of EPS specimens. With frozen EPS specimen the absorption continued increasing even after 48 months of immersion. Presumably the reason for such a behaviour is that the pore structure of EPS is not able to resist the tension caused by freezing water and therefore cracks are formed. Thus, more water absorbs inside the EPS through the cracks and it causes cracking deeper in the specimen which is why absorption increases after every freezing period.

  20. Laboratory Testing of Solar Combi System with Compact Long Term PCM Heat Storage

    DEFF Research Database (Denmark)

    Johansen, Jakob Berg; Englmair, Gerald; Dannemand, Mark

    2016-01-01

    To enable the transition from fossil fuels as a primary heat source for domestic hot water preparation and space heating solar thermal energy has great potential. The heat from the sun has the disadvantage that it is not always available when there is a demand. To solve this mismatch a thermal...... seasonal storage can be used to store excess heat from the summer to the winter when the demand is higher than the supply. Installing a long term thermal storage in a one family house it needs to be compact and sensible heat storages are not suitable. A latent heat storage with a phase change material (PCM...

  1. Testing long-term memory in animal models of schizophrenia: suggestions from CNTRICS.

    Science.gov (United States)

    Bussey, Timothy J; Barch, Deanna M; Baxter, Mark G

    2013-11-01

    This paper reports the results of discussions at the fourth meeting of Cognitive Neuroscience Treatment Research to Improve Cognition in Schizophrenia (CNTRICS) meeting, held over two days in Washington, DC in April 2011. The meeting focused on animal paradigms for assessing the cognitive constructs relevant to schizophrenia identified in previous CNTRICS meetings. This report focuses on the outcome of discussions in the general area of long-term memory. A number of candidate animal paradigms were discussed. Two of these - one for rodents and one for non-human primates - were recommended as particularly promising for further development. Copyright © 2013 Elsevier Ltd. All rights reserved.

  2. Intraindividual Variability and Long-Term Changes of Thermal Quantitative Sensory Testing

    DEFF Research Database (Denmark)

    Krøigård, Thomas; Sothynathan, Isaivani; Sindrup, Søren H

    2015-01-01

    Thermal threshold examinations are widely used in the clinical setting and in studies to assess the function of the peripheral sensory nervous system. Little is known about the variation from one side of the body to the other and the long-term temporal changes and variability. In this study, 134...... and foot. Bilateral stimulations resulted in relative intertrial variations ranging from 19% to 40%. There was no significant temporal change for repeated measures. Analysis of the individual measurements of each subject at baseline and at 26 weeks, however, resulted in relatively large intertrial...

  3. Trapping of gun-injected plasma by a tokamak

    International Nuclear Information System (INIS)

    Leonard, A.W.; Dexter, R.N.; Sprott, J.C.

    1986-10-01

    It is shown that a plasma produced by a Marshall gun can be injected into and trapped by a tokamak plasma. Gun injection raises the line-averaged density and peaks the density profile. Trapping of the gun-injected plasma is explainable in terms of a depolarization current mechanism. A model is developed which describes the slowing of a plasma beam crossing into the magnetic field of a tokamak. The slowing down time is shown to go as tau/sub s/ ∞ n -1 /sub b/T 3 /sub e/(α 0 /L) 2 , where n/sub b/ and T/sub e/ are the density and temperature of the plasma beam and α 0 /L is the pitch of the field lines per unit length in the direction in which the beam is traveling. Experimental tests of this model are consistent with the scaling predictions

  4. Measuring Attending Behavior and Short-Term Memory with Knox's Cube Test.

    Science.gov (United States)

    Stone, Mark H.; Wright, Benjamin D.

    1983-01-01

    A new revision was developed using Rasch psychometric techniques to build a Knox's Cube Test (KCT) variable and item bank using the tapping series from all previous editions. The report forms developed give a clear picture of the subject's performance set in a context that is both normative and criterion. (Author/BW)

  5. Short term creep small punch testing of P91 and P92 steels,

    Czech Academy of Sciences Publication Activity Database

    Dymáček, Petr

    2011-01-01

    Roč. 465, - (2011), s. 179-182 ISSN 1013-9826. [Materials Structure & Micromechanics of Fracture 6. Brno, 28.6.2010-30.6,2010] R&D Projects: GA AV ČR(CZ) IAA200410801 Institutional research plan: CEZ:AV0Z20410507 Keywords : creep * small punch test * chromium steel Subject RIV: JG - Metallurgy

  6. Technical requirements for the actinide source-term waste test program

    Energy Technology Data Exchange (ETDEWEB)

    Phillips, M.L.F.; Molecke, M.A.

    1993-10-01

    This document defines the technical requirements for a test program designed to measure time-dependent concentrations of actinide elements from contact-handled transuranic (CH TRU) waste immersed in brines similar to those found in the underground workings of the Waste Isolation Pilot Plant (WIPP). This test program wig determine the influences of TRU waste constituents on the concentrations of dissolved and suspended actinides relevant to the performance of the WIPP. These influences (which include pH, Eh, complexing agents, sorbent phases, and colloidal particles) can affect solubilities and colloidal mobilization of actinides. The test concept involves fully inundating several TRU waste types with simulated WIPP brines in sealed containers and monitoring the concentrations of actinide species in the leachate as a function of time. The results from this program will be used to test numeric models of actinide concentrations derived from laboratory studies. The model is required for WIPP performance assessment with respect to the Environmental Protection Agency`s 40 CFR Part 191B.

  7. Technical requirements for the actinide source-term waste test program

    International Nuclear Information System (INIS)

    Phillips, M.L.F.; Molecke, M.A.

    1993-10-01

    This document defines the technical requirements for a test program designed to measure time-dependent concentrations of actinide elements from contact-handled transuranic (CH TRU) waste immersed in brines similar to those found in the underground workings of the Waste Isolation Pilot Plant (WIPP). This test program wig determine the influences of TRU waste constituents on the concentrations of dissolved and suspended actinides relevant to the performance of the WIPP. These influences (which include pH, Eh, complexing agents, sorbent phases, and colloidal particles) can affect solubilities and colloidal mobilization of actinides. The test concept involves fully inundating several TRU waste types with simulated WIPP brines in sealed containers and monitoring the concentrations of actinide species in the leachate as a function of time. The results from this program will be used to test numeric models of actinide concentrations derived from laboratory studies. The model is required for WIPP performance assessment with respect to the Environmental Protection Agency's 40 CFR Part 191B

  8. Long term test of buffer material at the Aespoe Hard Rock Laboratory, LOT project. Final report on the A2 test parcel

    Energy Technology Data Exchange (ETDEWEB)

    Karnland, Ola; Olsson, Siv; Dueck, Ann; Birgersson, Martin; Nilsson, Ulf; Hernan-Haakansson, Tania (Clay Technology AB, Lund (Sweden)); Pedersen, Karsten (Microbial Analytics Sweden AB (Sweden); Goeteborg Univ., Dept. of Cell and Molecular Biology, Goeteborg (Sweden)); Nilsson, Sara; Eriksen, Trygve E. (School of Chemical Science and Engineering, Nuclear chemistry, Royal Inst. of Tech., Stockholm (Sweden)); Rosborg, Bo (Rosborg Consulting, Nykoeping (Sweden))

    2009-11-15

    In the Swedish repository concept for nuclear waste (KBS-3 concept), the spent nuclear fuel will be stored in copper canisters surrounded by compacted bentonite. The decaying power of the fuel will increase the temperature in the repository which, in combination with the uptake of ground-water, are expected to result in minor mineralogical changes in the bentonite. The ongoing LOT test series at the Aespoe Hard Rock Laboratory (HRL) are focused on identifying and quantifying such mineralogical alterations in the bentonite exposed to typical repository-like conditions. Further, buffer-related processes concerning copper corrosion, cation transport, and bacterial survival/activity are studied. In total, the LOT project includes seven test parcels, which contain a central Cu-tube surrounded by cylindrical bentonite blocks with a diameter of 30 cm, and gauges for temperature, total pressure, water pressure and humidity. Electrical heaters placed inside the copper tube are used to simulate the power from the decaying spent fuel. Three parcels are exposed to standard KBS-3 conditions (maximum temperature below 100 deg C) and four parcels to adverse conditions (maximum temperature below approx140 deg C). Both the standard and the adverse test series include short term tests (1 to 2 years), medium term tests (>5 years) and long term tests (>10 years). The present report concerns the A2 test parcel, which was a medium term test exposed to adverse conditions. Cu-coupons, 60Co tracers, bacteria and specific chemical substances were placed in the bentonite at defined positions. After field exposure, the entire test parcel was released from the rock by overlapping percussion drilling and wire sawing. The parcel was lifted and divided at test site and the bentonite material was sampled for specified analyses performed by nine different laboratories in five countries. The main aspects of the various tests and analyses may be summarized in the following items: - physical

  9. Concreteness effects in short-term memory: a test of the item-order hypothesis.

    Science.gov (United States)

    Roche, Jaclynn; Tolan, G Anne; Tehan, Gerald

    2011-12-01

    The following experiments explore word length and concreteness effects in short-term memory within an item-order processing framework. This framework asserts order memory is better for those items that are relatively easy to process at the item level. However, words that are difficult to process benefit at the item level for increased attention/resources being applied. The prediction of the model is that differential item and order processing can be detected in episodic tasks that differ in the degree to which item or order memory are required by the task. The item-order account has been applied to the word length effect such that there is a short word advantage in serial recall but a long word advantage in item recognition. The current experiment considered the possibility that concreteness effects might be explained within the same framework. In two experiments, word length (Experiment 1) and concreteness (Experiment 2) are examined using forward serial recall, backward serial recall, and item recognition. These results for word length replicate previous studies showing the dissociation in item and order tasks. The same was not true for the concreteness effect. In all three tasks concrete words were better remembered than abstract words. The concreteness effect cannot be explained in terms of an item-order trade off. PsycINFO Database Record (c) 2011 APA, all rights reserved.

  10. Echoic and retrieval accounts of the long-term modality effect tested using the suffix procedure.

    Science.gov (United States)

    Huang, S T; Glenberg, A M

    1986-01-01

    The long-term modality effect is the advantage in recall of the last of a list of auditory to-be-remembered (TBR) items compared with the last of a list of visual TBR items when the list is followed by a filled retention interval. If the auditory advantage is due to echoic sensory memory mechanisms, then recall of the last auditory TBR item should be substantially reduced when it is followed by a redundant, not-to-be-recalled auditory suffix. Contrary to this prediction, Experiment 1 demonstrated that a redundant auditory suffix does not significantly reduce recall of the last auditory TBR item. In Experiment 2 a nonredundant auditory suffix produced a large reduction in the last auditory item. Redundancy is not the only factor controlling the effectiveness of a suffix, however. Experiment 3 demonstrated that a nonredundant visual suffix does not reduce recall of the last auditory TBR item. These results are discussed in reference to a retrieval account of the long-term modality effect.

  11. Results on long-term performances and laboratory tests of the L3 RPC system at LEP

    CERN Document Server

    Alviggi, M G; Conventi, F; De Asmundis, R; Della Pietra, M; Della Volpe, D; Patricelli, S; Paolucci, P; Piccolo, D; Sciacca, C; Sekhniaidze, G

    2003-01-01

    The RPC detectors in the L3 experiment at LEP work as a trigger system for the Forward-Backward Muon Spectrometer. It consists of 192 bi-gap RPCs working in streamer mode. We monitored the behaviour of the system over seven years of data taking at LEP. To investigate the ageing of the RPCs after this long-term operation, we report the main results obtained from 1994 to 2000, together with the results of tests performed on some RPC chambers in our test site in Napoli with cosmic rays after the dismantling of L3.

  12. Constrained prose recall and the assessment of long-term forgetting: the case of ageing and the Crimes Test.

    Science.gov (United States)

    Baddeley, Alan; Rawlings, Bruce; Hayes, Amie

    2014-01-01

    It has become increasingly clear that some patients with apparently normal memory may subsequently show accelerated long-term forgetting (ALF), with dramatic loss when retested. We describe a constrained prose recall task that attempts to lay the foundations for a test suitable for detecting ALF sensitively and economically. Instead of the usual narrative structure of prose recall tests, it employs a matrix structure involving four episodes, each describing a minor crime, with each crime involving the binding into a coherent episode of a specified range of features, involving the victim, the crime, the criminal and the location, allowing a total of 80 different probed recall questions to be generated. These are used to create four equivalent 20-item tests, three of which are used in the study. After a single verbal presentation, young and elderly participants were tested on three occasions, immediately, and by telephone after a delay of 6 weeks, and at one of a varied range of intermediate points. The groups were approximately matched on immediate test; both showed systematic forgetting which was particularly marked in the elderly. We suggest that constrained prose recall has considerable potential for the study of long-term forgetting.

  13. Long-Term Durability Test for the Left Ventricular Assist System EVAHEART under the Physiologic Pulsatile Load.

    Science.gov (United States)

    Kitano, Tomoya; Iwasaki, Kiyotaka

    The EVAHEART Left Ventricular Assist System (LVAS) was designed for the long-term support of a patient with severe heart failure. It has an original water lubrication system for seal and bearing and wear on these parts was considered one of its critical failure modes. A durability test focusing on wear was designed herein. We developed a mock loop, which generates a physiologic pulsatile flow and is sufficiently durable for a long-term test. The pulsatile load and the low fluid viscosity enable the creation of a severe condition for the mechanical seal. A total of 18 EVAHEART blood pumps completed 2 years of operation under the pulsatile condition without any failure. It indicated the EVAHEART blood pump had a greater than 90% reliability with a 88% confidence level. The test was continued with six blood pumps and achieved an average of 8.6 years, which was longer than the longest clinical use in Japan. The test result showed that no catastrophic, critical, marginal, or minor failures of the blood pump or their symptoms were observed. The seal performance was maintained after the test. Moreover, the surface roughness did not change, which showed any burn or abnormal wear occurred. The original water lubrication system equipped in EVAHEART LVAS prevent severe wear on the seal and the bearing, and it can be used in the bridge to transplant and destination therapy.

  14. Modelling of degradation processes in creep resistant steels through accelerated creep tests after long-term isothermal ageing

    Energy Technology Data Exchange (ETDEWEB)

    Sklenicka, V.; Kucharova, K.; Svoboda, M.; Kroupa, A.; Kloc, L. [Academy of Sciences of the Czech Republic, Brno (Czech Republic). Inst. of Physics of Materials; Cmakal, J. [UJP PRAHA a.s., Praha-Zbraslav (Czech Republic)

    2010-07-01

    Creep behaviour and degradation of creep properties of creep resistant materials are phenomena of major practical relevance, often limiting the lives of components and structures designed to operate for long periods under stress at elevated and/or high temperatures. Since life expectancy is, in reality, based on the ability of the material to retain its high-temperature creep strength for the projected designed life, methods of creep properties assessment based on microstructural evolution in the material during creep rather than simple parametric extrapolation of short-term creep tests are necessary. In this paper we will try to further clarify the creep-strength degradation of selected advanced creep resistant steels. In order to accelerate some microstructural changes and thus to simulate degradation processes in long-term service, isothermal ageing at 650 C for 10 000 h was applied to P91 and P23 steels in their as-received states. The accelerated tensile creep tests were performed at temperature 600 C in argon atmosphere on all steels both in the as-received state and after long-term isothermal ageing, in an effort to obtain a more complete description of the role of microstructural stability in high temperature creep of these steels. Creep tests were followed by microstructural investigations by means of both transmission and scanning electron microscopy and by the thermodynamic calculations. The applicability of the accelerated creep tests was verified by the theoretical modelling of the phase equilibria at different temperatures. It is suggested that under restructed oxidation due to argon atmosphere microstructural instability is the main detrimental process in the long-term degradation of the creep rupture strength of these steels. (orig.)

  15. Testing causes for long-term changes in carbon cycling and climate during the early Paleogene

    Science.gov (United States)

    Komar, N.; Zeebe, R. E.; Dickens, G. R.

    2013-12-01

    The late Paleocene to the early Eocene (˜58-52 Ma) was marked by significant changes in global climate and carbon cycling. Among the evidence for these changes, stable isotope records reveal a prominent decrease of δ13C and δ18O (in both surface and deep ocean), indicating a reorganization in the long-term global carbon cycle and a long-term warming trend (˜4°C), respectively. Concurrently, deep-sea carbonate records at several sites indicate a deepening of the calcite compensation depth (CCD). Here, we investigate possible causes (e.g., increased volcanic degassing, decreased net organic burial, and accelerated dissociation of gas hydrate) for these observations, but from a new perspective. The basic model employed is a modified version of GEOCARB III. However, we have coupled this well-known geochemical model to LOSCAR, a model that enables simulation of seawater carbonate chemistry, the CCD, and ocean δ13C. We have also added a gas hydrate capacitor that can account for the storage and release of methane from the seafloor over millions of years. We further consider accurate input data (e.g., δ13C of carbonate) on a currently accepted time scale that spans an interval much longer than the perturbation. Several different scenarios are investigated with the goal of consistency amongst inferred changes in temperature, the CCD, and surface ocean and deep ocean δ13C. The results strongly suggest that a decrease in net organic carbon burial drove carbon cycle changes during the late Paleocene and early Eocene, although an increase in volcanic activity might have contributed. Importantly, a drop in net organic carbon burial may represent increased oxidation of previously deposited organic carbon, such as stored in peat or gas hydrates. The model successfully recreates trends in Earth surface warming, as inferred from δ18O records, the CCD, and δ13C. At the moment, however, our coupled modeling effort cannot reproduce the magnitude of change in all these

  16. The Mid-Term Changes of Pulmonary Function Tests After Phrenic Nerve Transfer.

    Science.gov (United States)

    Yavari, Masoud; Hassanpour, Seyed Esmail; Khodayari, Mohammad

    2016-03-01

    In the restoration of elbow flexion, the phrenic nerve has proven to be a good donor, but considering the role of the phrenic nerve in respiratory function, we cannot disregard the potential dangers of this method. In the current study, we reviewed the results of pulmonary function tests (PFT) in four patients who underwent phrenic nerve transfer. We reviewed the results of serial spirometry tests, which were performed before and after phrenic nerve transfer surgery. All patients regained Biceps power to M3 strength or above. None of our patients experienced pulmonary problems or respiratory complaints, but a significant reduction of spirometric parameters occurred after surgery. This study highlights the close link between the role of the phrenic nerve and pulmonary function, such that the use of this nerve as a transfer donor leads to spirometric impairments.

  17. Integrity Assessment of HANARO Irradiation Capsule for Long-Term Irradiation Testing

    Energy Technology Data Exchange (ETDEWEB)

    Choo, Kee Nam; Cho, Man Soon; Yang, Sung Woo; Shin, Yoon Taek; Park, Seng Jae; Yang, Tae Ho; Jun, Byung Hyuk; Kim, Myong Seop [KAERI, Daejeon (Korea, Republic of); Hong, Sang Hyun [Chungnam University, Daejeon (Korea, Republic of)

    2016-05-15

    The capsule technology was basically developed for irradiation testing under a commercial reactor operation environment. Most irradiation testing using capsules has been performed at around 300 .deg. C within four reactor operation cycles (about 100 days equivalent to 1.5 dpa (displacement for atom)) at HANARO. Based on the accumulated experience as well as the sophisticated requirements of users, HANARO has recently been required to support national R and D projects requiring much higher neutron fluence. To scope the user requirements for higher neutron irradiation fluence, several efforts using an instrumented capsule have been applied at HANARO. In this paper, the applied stresses on the capsule are estimated because the capsule was suspected to be susceptible to fatigue failure during irradiation testing. In addition, the on-going design improvements of the irradiation capsule for higher neutron irradiation fluence at HANARO are described. The applied stresses on the rod tip were analyzed using the ANSYS program. The applied stresses on the rod tip can be classified into stresses by the designed bottom spring, by the upward flowing coolant, by the capsule vibration, and by the welding residual stress. The maximal stresses due to the first three factors were estimated as 5.4 MPa, 132.9 MPa, and 161 MPa, respectively. These stresses do not exceed the known fatigue strength of stainless steels (∼300 MPa). Residual stress by welding is another possible stress and it is known to occur at up to about 300 MPa.

  18. Development of a mechanical testing and loading system for trabecular bone studies for long term culture

    Directory of Open Access Journals (Sweden)

    DB Jones

    2003-03-01

    Full Text Available A highly accurate (�3% mechanical loading and measurement system combined with a trabecular bone diffusion culture-loading chamber has been developed, which provides the ability to study trabecular bone (and possibly cartilage under controlled culture and loading conditions over long periods of time. The loading device has been designed to work in two main modes, either to apply a specific compressive strain to a trabecular bone cylinder or to apply a specific force and measure the resulting deformation. Presently, precisely machined bone cylinders can be loaded at frequencies between 0.1 Hz to 50 Hz and amplitudes over 7,000�e. The system allows accurate measurement of many mechanical properties of the tissue in real time, including visco-elastic properties. This paper describes the technical components, reproducibility, precision, and the calibration procedures of the loading system. Data on long term culture and mechanical responses to different loading patterns will be published separately.

  19. Low-level radioactive waste source term model development and testing: Topical report

    International Nuclear Information System (INIS)

    Sullivan, T.M.; Kempf, C.R.; Suen, C.J.; Mughabghab, S.M.

    1988-08-01

    The Low-Level Waste Source Term Evaluation Project has the objective to develop a system model capable of predicting radionuclide release rates from a shallow land burial facility. The previous topical report for this project discussed the framework and methodology for developing a system model and divided the problem into four compartments: water flow, container degradation, waste form leaching, and radionuclide transport. Each of these compartments is described by submodels which will be coupled into the system model. From February 1987 to March 1988, computer models have been selected to predict water flow (FEMWATER) and radionuclide transport (FEMWASTE) and separate models have been developed to predict pitting corrosion of steel containers and leaching from porous waste forms contained in corrodible containers. This report discusses each of the models in detail and presents results obtained from applying the models to shallow land burial trenches over a range of expected conditions. 68 refs., 34 figs., 14 tabs

  20. OECD MCCI project long-term 2-D molten core concrete interaction test design report, Rev. 0. September 30, 2002

    International Nuclear Information System (INIS)

    Farmer, M.T.; Kilsdonk, D.J.; Lomperski, S.; Aeschliman, R.W.; Basu, S.

    2011-01-01

    The Melt Attack and Coolability Experiments (MACE) program at Argonne National Laboratory addressed the issue of the ability of water to cool and thermally stabilize a molten core-concrete interaction when the reactants are flooded from above. These tests provided data regarding the nature of corium interactions with concrete, the heat transfer rates from the melt to the overly