WorldWideScience

Sample records for terbium ions

  1. Green fluorescence of terbium ions in lithium fluoroborate glasses ...

    Indian Academy of Sciences (India)

    Glasses; terbium ion; oscillator strengths; fluorescence; lifetimes; fibre lasers. 1. Introduction. Today glasses are most favourable engineering materials for abundant applications due to the wide ability of property altering by compositional modifications. The considerable examination of glass science to achieve required ...

  2. Green fluorescence of terbium ions in lithium fluoroborate glasses ...

    Indian Academy of Sciences (India)

    Home; Journals; Bulletin of Materials Science; Volume 39; Issue 3. Green fluorescence of terbium ions in lithium fluoroborate glasses for fibre lasers and display devices. G R DILLIP C MADHUKAR REDDY M RAJESH SHIVANAND CHAURASIA B DEVA PRASAD RAJU S W JOO. Volume 39 Issue 3 June 2016 pp 711-717 ...

  3. Graphene quantum dots-terbium ions as novel sensitive and selective time-resolved luminescent probes.

    Science.gov (United States)

    Llorent-Martínez, Eulogio J; Durán, Gema M; Ríos, Ángel; Ruiz-Medina, Antonio

    2018-01-01

    We propose an alternative approach for the development of analytical methods based on terbium-sensitized luminescence (TSL). TSL is based on the complexation between Tb(III) ions and fluorescent organic compounds that have appropriate functional groups to complex with Tb(III). We report the use of graphene quantum dot (GQDs) nanoparticles to improve the sensitivity and selectivity of TSL detection. GQDs can react with terbium ions through the carboxylic groups present in their structure. These Tb(III)-GQD complexes, formed in situ in aqueous solution, can be used as time-resolved luminescent probes. Ascorbic acid was selected as a target analyte to demonstrate the suitability of the proposed method. The selectivity of the TSL method was highly improved for most of the interferences tested. Under the optimum conditions [Tb(III) concentration 5 × 10-4 mol L-1, GQD concentration 4 mg L-1], a minimum 100% increase in selectivity was observed for several vitamins and common cations that may be present in the samples to be analyzed. In addition, the analytical signal showed a 30% enhancement with the use of GQDs compared with the use of merely Tb(III) ions, with a detection limit of 0.12 μg mL-1. The repeatability and intermediate precision were lower than 3% and 5%, respectively. From the results obtained, the implementation of GQDs in TSL can lead to the development of novel time-resolved luminescent probes with high analytical potential. Graphical abstract Quenching of Tb(III)-graphene quantum dot (GQD) luminescence by ascorbic acid (AA). TBL terbium-sensitized luminescence.

  4. A New Bis(phthalocyaninato) Terbium Single-Ion Magnet with an Overall Excellent Magnetic Performance.

    Science.gov (United States)

    Chen, Yuxiang; Ma, Fang; Chen, Xiaoxiang; Dong, Bowei; Wang, Kang; Jiang, Shangda; Wang, Chiming; Chen, Xin; Qi, Dongdong; Sun, Haoling; Wang, Bingwu; Gao, Song; Jiang, Jianzhuang

    2017-11-20

    Bulky and strong electron-donating dibutylamino groups were incorporated onto the peripheral positions of one of the two phthalocyanine ligands in the bis(phthalocyaninato) terbium complex, resulting in the isolation of heteroleptic double-decker (Pc)Tb{Pc[N(C4H9)2]8} {Pc = phthalocyaninate; Pc[N(C4H9)2]8 = 2,3,9,10,16,17,23,24-octakis(dibutylamino)phthalocyaninate} with the nature of an unsymmetrical molecular structure, a square-antiprismatic coordination geometry, an intensified coordination field strength, and the presence of organic radical-f interaction. As a total result of all these factors, this sandwich-type tetrapyrrole lanthanide single-ion magnet (SIM) exhibits an overall enhanced magnetic performance including a high blocking temperature (TB) of 30 K and large effective spin-reversal energy barrier of Ueff = 939 K, rendering it the best sandwich-type tetrapyrrole lanthanide SIM reported thus far.

  5. Highly efficient precipitation of phosphoproteins using trivalent europium, terbium, and erbium ions

    Energy Technology Data Exchange (ETDEWEB)

    Guezel, Yueksel; Rainer, Matthias; Mirza, Munazza Raza; Bonn, Guenther K. [Leopold-Franzens University, Institute of Analytical Chemistry and Radiochemistry, Innsbruck (Austria)

    2012-05-15

    This study describes a highly efficient method for the selective precipitation of phosphoproteins by trivalent europium, terbium, and erbium metal ions. These metal cations belong to the group of lanthanides and are known to be hard acceptors with an overwhelming preference for oxygen-containing anions such as phosphates to which they form very tight ionic bonds. The method could be successfully applied to specifically precipitate phosphoproteins from complex samples including milk and egg white by forming solid metal-protein complexes. Owing to the low solubility product of the investigated lanthanide salts, the produced metal-protein complexes showed high stability. The protein pellets were extensively washed to remove nonphosphorylated proteins and contaminants. For the analysis of proteins the pellets were first dissolved in 30 % formic acid and subjected to matrix-assisted laser desorption/ionization-time of flight (MALDI-TOF) MS. For peptide mass-fingerprint analysis the precipitated phosphoproteins were enzymatically digested using microwave-assisted digestion. The method was found to be highly specific for the isolation and purification of phosphoproteins. Protein quantification was performed by colorimetric detection of total precipitated phosphoproteins and revealed more than 95 % protein recovery for each lanthanide salt. (orig.)

  6. Sensitization effects of supramolecular assemblies on the luminescence of terbium-ion prulifloxacin complexes

    Energy Technology Data Exchange (ETDEWEB)

    Wang Hong; Yi Chongyue; Li Xue; Fang Fang [School of Chemistry and Chemical Engineering, Huazhong University of Science and Technology, Wuhan 430074 (China); Yang Yajiang, E-mail: yjyang@mail.hust.edu.c [School of Chemistry and Chemical Engineering, Huazhong University of Science and Technology, Wuhan 430074 (China)

    2011-04-15

    Luminescence enhancement of terbium-ion prulifloxacin complexes (Tb(III)-PUFX) in supramolecular hydrogels formed by assembly of 1,3:2,4-di-O-benzylidene-D-sorbitol (DBS) was investigated by steady-state fluorescence, varying temperature fluorescence and time-resolved fluorescence. The luminescence images show that Tb(III)-PUFX were dispersed in the DBS gels. The luminescence intensity of Tb(III)-PUFX in the DBS gels was significantly increased in comparison with that in corresponding aqueous solutions. The varying temperature fluorescent spectra show that the luminescence intensity of Tb(III)-PUFX decreased with an increase in the temperature. This implies that the luminescence enhancement of Tb(III)-PUFX is related to the dissociation and the formation of the DBS assemblies. Time-resolved fluorescence measurements show slower rotational motion in DBS gels in comparison with that in the corresponding aqueous solutions. This may be ascribed to a unique microstructure of three-dimensional network formed by DBC aggregates, resulting in deactivation of the nonradiative relaxation. The images of field emission scanning electron microscopy and polarized optical microscopy indicate that the morphology of the DBS assemblies was not influenced upon addition of Tb(III)-PUFX to the DBS gels.

  7. Lanthanides in Nuclear Medicine. The Production of Terbium-149 by Heavy Ion Beams

    CERN Document Server

    Dmitriev, S N; Zaitseva, N G; Maslov, O D; Molokanova, L G; Starodub, G Ya; Shishkin, S V; Shishkina, T V

    2001-01-01

    Among radioactive isotopes of lanthanide series elements, finding the increasing using in nuclear medicine, alpha-emitter {149}Tb (T_{1/2} = 4.118 h; EC 76.2 %; beta^+ 7.1 %; alpha 16.7 %) is considered as a perspective radionuclide for radioimmunotherapy. The aim of the present work is to study experimental conditions of the {149}Tb production in reactions Nd({12}C, xn){149}Dy (4.23 min; beta^+, EC)\\to {149}Tb when the Nd targets have been irradiated by heavy ions of carbon. On the basis of results of formation and decay of {149}Dy\\to{149}Tb evaluation of the {149}Tb activity, is made which can be received under optimum conditions (enriched {142}Nd target, {12}C ions with the energy 120 MeV and up to current 100 mu A, time of irradiating 8-10 hours). Under these conditions {149}Tb can be obtained up to 30 GBq (up to 0.8 Ci).

  8. Self-diffusion coefficients of the trivalent f-element ion series in dilute and moderately dilute aqueous solutions: A comparative study between europium, gadolinium, terbium and berkelium

    Science.gov (United States)

    Rafik, Besbes; Noureddine, Ouerfelli; Abderabbou, Abdelmanef; Habib, Latrous

    2010-03-01

    We have continued the studies on the trivalent ions of the 4f and 5f elements. In this paper, we compare the transport properties (self-diffusion coefficient) of the trivalent aquo ions over two ranges of concentrations (0 — 2×10-3M) and (2×10-3 — 1.5M). Self-diffusion coefficients, D, of the trivalent f-element aquo ion series have been determined in aqueous background electrolytes of Gd(NO3)3 and Nd(ClO4)3, at pH=2.5 (HNO3, HClO4) and at 25°C using the open-end capillary method (O.E.C.M.). This method measures the transportation time of ions across a fixed distance. In this paper, we complete a measurement of self-diffusion coefficient for terbium. We optimized the pH to avoid hydrolysis, ion-pairing and complexation of the trivalent 4f and 5f ions. The variation of D versus √C is not linear for dilute solutions (0 — 2×10-3M) and quasi-linear in moderate concentrations (C<=1.5 M). Similar behavior was observed for Tb, as compared with those for Bk, Eu and Gd. We complete the comparison variation of D/D° versus √C for all studied 4f and 5f elements from concentration 0 to 1.5M and we obtained the same variation with √C for all studied elements. All 4f and 5f elements studied follow the Nernst-Hartley expression.

  9. A Terbium Metal-Organic Framework for Highly Selective and Sensitive Luminescence Sensing of Hg2+Ions in Aqueous Solution.

    Science.gov (United States)

    Xia, Tifeng; Song, Tao; Zhang, Gege; Cui, Yuanjing; Yang, Yu; Wang, Zhiyu; Qian, Guodong

    2016-12-19

    A series of isomorphic lanthanide metal-organic frameworks (MOFs) Ln(TATAB)⋅(DMF) 4 (H 2 O)(MeOH) 0.5 (LnTATAB, Ln=Eu, Tb, Sm, Dy, Gd; H 3 TATAB=4,4',4''-s-triazine-1,3,5-triyltri-p-aminobenzoic acid) have been solvothermally synthesized and structurally characterized. Among these MOFs, TbTATAB exhibits good water stability and a high fluorescence quantum yield. Because mercury ions (Hg 2+ ) have a high affinity to nitrogen atoms, and the space between multiple nitrogen atoms from triazine and imino groups is suitable for interacting with Hg 2+ ions, TbTATAB shows highly selective and sensitive detection of Hg 2+ in aqueous solution with a detection limit of 4.4 nm. Furthermore, it was successfully applied to detect Hg 2+ ions in natural water samples. © 2016 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Selective Sensing of Fe(3+) and Al(3+) Ions and Detection of 2,4,6-Trinitrophenol by a Water-Stable Terbium-Based Metal-Organic Framework.

    Science.gov (United States)

    Cao, Li-Hui; Shi, Fang; Zhang, Wen-Min; Zang, Shuang-Quan; Mak, Thomas C W

    2015-10-26

    A water-stable luminescent terbium-based metal-organic framework (MOF), {[Tb(L1 )1.5 (H2 O)]⋅3 H2 O}n (Tb-MOF), with rod-shaped secondary building units (SBUs) and honeycomb-type tubular channels has been synthesized and structurally characterized by single-crystal X-ray diffraction. The high green emission intensity and the microporous nature of the Tb-MOF indicate that it can potentially be used as a luminescent sensor. In this work, we show that Tb-MOF can selectively sense Fe(3+) and Al(3+) ions from mixed metal ions in water through different detection mechanisms. In addition, it also exhibits high sensitivity for 2,4,6-trinitrophenol (TNP) in the presence of other nitro aromatic compounds in aqueous solution by luminescence quenching experiments. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Crystal structure of an eight-coordinate terbium(III ion chelated by N,N′-bis(2-hydroxybenzyl-N,N′-bis(pyridin-2-ylmethylethylenediamine (bbpen2− and nitrate

    Directory of Open Access Journals (Sweden)

    Thaiane Gregório

    2015-01-01

    Full Text Available The reaction of terbium(III nitrate pentahydrate in acetonitrile with N,N′-bis(2-hydroxybenzyl-N,N′-bis(pyridin-2-ylmethylethylenediamine (H2bbpen, previously deprotonated with triethylamine, produced the mononuclear compound [N,N′-bis(2-oxidobenzyl-κO-N,N′-bis(pyridin-2-ylmethyl-κNethylenediamine-κ2N,N′](nitrato-κ2O,O′terbium(III, [Tb(C28H28N4O2(NO3]. The molecule lies on a twofold rotation axis and the TbIII ion is eight-coordinate with a slightly distorted dodecahedral coordination geometry. In the symmetry-unique part of the molecule, the pyridine and benzene rings are both essentially planar and form a dihedral angle of 61.42 (7°. In the molecular structure, the N4O4 coordination environment is defined by the hexadentate bbpen ligand and the bidentate nitrate anion. In the crystal, a weak C—H...O hydrogen bond links molecules into a two-dimensional network parallel to (001.

  12. Elastic properties of terbium

    DEFF Research Database (Denmark)

    Spichkin, Y.I.; Bohr, Jakob; Tishin, A.M.

    1996-01-01

    The temperature dependence of the Young modulus along the crystallographic axes b and c (E(b) and E(c)), and the internal friction of a terbium single crystal have been measured. At 4.2 K, E(b) and E(c) are equal to 38 and 84.5 GPa, respectively. The lattice part of the Young modulus and the Debye...... temperature has been calculated. The origin of the Young modulus anomalies arising at the transition to the magnetically ordered state is discussed....

  13. A Water-Stable Dual-Channel Luminescence Sensor for UO22+Ions Based on an Anionic Terbium(III) Metal-Organic Framework.

    Science.gov (United States)

    Ye, Junwei; Bogale, Raji F; Shi, Yangwei; Chen, Yanzhen; Liu, Xigang; Zhang, Siqi; Yang, Yaoyao; Zhao, Jianzhang; Ning, Guiling

    2017-06-07

    A stable 3D Tb III -based metal-organic framework [Tb(BPDC) 2 ]⋅(CH 3 ) 2 NH 2 (DUT-101) was synthesized, and it is the first efficient dual-channel luminescence sensor for aqueous UO 2 2+ ions. DUT-101 contains an anionic three-dimensional framework and protonated dimethylamine molecules embedded within the channels. The intense green emission of DUT-101 could be highly selectively and sensitively quenched by UO 2 2+ ions even in the presence of other competing metal ions. A possible sensing mechanism was proposed based on both suppression of luminescence resonance energy transfer and enhancement of intermolecular electron transfer. Furthermore, visual green fluorescent test papers based on DUT-101 were fabricated and could be used to discriminate UO 2 2+ ions among various metal ions. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Preparation, characterization, and properties of PMMA-doped polymer film materials: a study on the effect of terbium ions on luminescence and lifetime enhancement.

    Science.gov (United States)

    Zhang, Hui-Jie; Fan, Rui-Qing; Wang, Xin-Ming; Wang, Ping; Wang, Yu-Lei; Yang, Yu-Lin

    2015-02-14

    Poly(methylmethacrylate) (PMMA) doped with Tb-based imidazole derivative coordination polymer {[Tb(3)(L)(μ(3)-OH)(7)]·H(2)O}(n) (1) (L = N,N'-bis(acetoxy)biimidazole) was synthesized and its photophysical properties were studied. The L'(L' = N,N'-bis(ethylacetate)biimidazole) ligand was synthesized by an N-alkylation reaction process followed by ester hydrolysis to produce ligand L. Polymer 1 and ligand L' have been characterized by (1)H NMR and IR spectroscopy, elemental analysis, PXRD and X-ray single-crystal diffraction. Coordination polymer 1 is the first observation of a CdCl(2) structure constructed with hydroxy groups and decorated by ligand L in lanthanide N-heterocyclic coordination polymers. In the 2D layered structure of 1, each Tb3 metal center is connected with three Tb1 and three Tb2 metal centers by seven hydroxyl groups in different directions, resulting in a six-membered ring. After doping, not only the luminescence intensity and lifetime enhanced, but also their thermal stability was increased in comparison with 1. When 1 was doped into poly(methylmethacrylate) (1@PMMA), polymer film materials were formed with the PMMA polymer matrix (w/w = 2.5%-12.5%) acting as a co-sensitizer for Tb(3+) ions. The luminescence intensity of the Tb(3+) emission at 544 nm increases when the content of Tb(3+) was 10%. The lifetime of 1@PMMA (914.88 μs) is more than four times longer than that of 1 (196.24 μs). All τ values for the doped polymer systems are higher than coordination polymer 1, indicating that radiative processes are operative in all the doped polymer films. This is because PMMA coupling with the O-H oscillators from {[Tb(3)(L)(μ(3)-OH)(7)]·H(2)O}(n) can suppress multiphonon relaxation. According to the variable-temperature luminescence (VT-luminescence) investigation, 1@PMMA was confirmed to be a stable green luminescent polymer film material.

  15. Genetically Encoded FRET-Sensor Based on Terbium Chelate and Red Fluorescent Protein for Detection of Caspase-3 Activity

    Directory of Open Access Journals (Sweden)

    Alexander S. Goryashchenko

    2015-07-01

    Full Text Available This article describes the genetically encoded caspase-3 FRET-sensor based on the terbium-binding peptide, cleavable linker with caspase-3 recognition site, and red fluorescent protein TagRFP. The engineered construction performs two induction-resonance energy transfer processes: from tryptophan of the terbium-binding peptide to Tb3+ and from sensitized Tb3+ to acceptor—the chromophore of TagRFP. Long-lived terbium-sensitized emission (microseconds, pulse excitation source, and time-resolved detection were utilized to eliminate directly excited TagRFP fluorescence and background cellular autofluorescence, which lasts a fraction of nanosecond, and thus to improve sensitivity of analyses. Furthermore the technique facilitates selective detection of fluorescence, induced by uncleaved acceptor emission. For the first time it was shown that fluorescence resonance energy transfer between sensitized terbium and TagRFP in the engineered construction can be studied via detection of microsecond TagRFP fluorescence intensities. The lifetime and distance distribution between donor and acceptor were calculated using molecular dynamics simulation. Using this data, quantum yield of terbium ions with binding peptide was estimated.

  16. Critical scattering of neutrons from terbium

    DEFF Research Database (Denmark)

    Als-Nielsen, Jens Aage; Dietrich, O.W.; Marshall, W.

    1968-01-01

    The inelasticity of the critical scattering of neutrons in terbium has been measured above the Neél temperature at the (0, 0, 2−Q) satellite position. The results show that dynamic slowing down of the fluctuations does occur in a second‐order phase transition in agreement with the general theory...

  17. Semiconductor composition containing iron, dysprosium, and terbium

    Energy Technology Data Exchange (ETDEWEB)

    Pooser, Raphael C.; Lawrie, Benjamin J.; Baddorf, Arthur P.; Malasi, Abhinav; Taz, Humaira; Farah, Annettee E.; Kalyanaraman, Ramakrishnan; Duscher, Gerd Josef Mansfred; Patel, Maulik K.

    2017-09-26

    An amorphous semiconductor composition includes 1 to 70 atomic percent iron, 15 to 65 atomic percent dysprosium, 15 to 35 atomic percent terbium, balance X, wherein X is at least one of an oxidizing element and a reducing element. The composition has an essentially amorphous microstructure, an optical transmittance of at least 50% in at least the visible spectrum and semiconductor electrical properties.

  18. Arginine-responsive terbium luminescent hybrid sensors triggered by two crown ether carboxylic acids

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, Lasheng [Key Laboratory of Theoretical Chemistry of Environment, Ministry of Education, School of Chemistry and Environment, South China Normal University, Guangzhou 510006 (China); School of Chemistry and Environment, South China Normal University, Guangzhou 510006 (China); Tang, Ke; Ding, Xiaoping [School of Chemistry and Environment, South China Normal University, Guangzhou 510006 (China); Wang, Qianming, E-mail: qmwang@scnu.edu.cn [Key Laboratory of Theoretical Chemistry of Environment, Ministry of Education, School of Chemistry and Environment, South China Normal University, Guangzhou 510006 (China); School of Chemistry and Environment, South China Normal University, Guangzhou 510006 (China); Zhou, Zhan; Xiao, Rui [School of Chemistry and Environment, South China Normal University, Guangzhou 510006 (China)

    2013-12-01

    Crown ether carboxylic acids constitute main building blocks for the synthesis of terbium containing covalent cross-linked luminescent materials. Both the complexes and the hybrid nanomaterials could exhibit remarkable green emissions in pure water. More importantly, they were found to have a profound effect on the luminescence responses to arginine compared with glutamic acid, histidine, tryptophan, threonine, tyrosine and phenylalanine in aqueous environment. The present study provided the possibility of using a host–guest mechanism as a way of signal transduction based on lanthanide supramolecular hybrid materials. - Highlights: • Crown ether carboxylic acids were found to sensitize terbium ions among a group of ethers. • The complexes and silica hybrid materials were both prepared and characterized. • They could exhibit remarkable green emissions in pure water.

  19. Study of Silver Nanoparticles Sensitized Fluorescence and Second-Order Scattering of Terbium(III-Pefloxacin Mesylate Complex and Determination of Pefloxacin Mesylate

    Directory of Open Access Journals (Sweden)

    Aiyun Li

    2014-01-01

    Full Text Available α-Keto acid of pefloxacin mesylate (PFLX can form the complex with Terbium(III. The intramolecular energy from PFLX to Terbium(III ion takes place when excited, and thus Terbium(III excited state is formed and then emits the characteristic fluorescence of Terbium(III, locating at 490, 545, 580, and 620 nm. The second-order scattering (SOS peak at 545 nm also appears for the complex with the exciting wavelength of 273 nm. When the silver nanoparticles are added to the system, the luminescence intensity at 545 nm greatly increased. So, with the adding of nanoparticles to the Terbium(III-PFLX complex, not only is the intramolecular energy promoted but also the SOS intensity is enhanced. The experimental results show that it is the silver nanoparticles with certain size and certain concentration which can greatly enhance the fluorescence-SOS intensity, and the relative intensity at 545 nm is proportional to the amount of PFLX. Based on this phenomenon, a novel method for the determination of PFLX has been developed and applied to the determination of PFLX in capsule and serum samples.

  20. Sodium terbium(III polyphosphate

    Directory of Open Access Journals (Sweden)

    Abdelghani Oudahmane

    2010-04-01

    Full Text Available Single crystals of the title compound, NaTb(PO34, were obtained by solid-state reaction. This compound belongs to type II of long-chain polyphosphates with the general formula AIBIII(PO34. It is isotypic with the NaNd(PO34 and NaEr(PO34 homologues. The crystal structure is built up of infinite crenelated chains of corner-sharing PO4 tetrahedra with a repeating unit of four tetrahedra. These chains, extending parallel to [100], are linked by isolated TbO8 square antiprisms, forming a three-dimensional framework. The Na+ ions are located in channels running along [010] and are surrounded by six oxygen atoms in a distorted octahedral environment within a cut-off distance <2.9 Å.

  1. Structural and optical characterization of terbium doped ZnGa2O4 thin films deposited by RF magnetron sputtering

    Science.gov (United States)

    Somasundaram, K.; Girija, K. G.; Sudarsan, V.; Selvin, P. Christopher; Vatsa, R. K.

    2016-05-01

    Tb3+ doped ZnGa2O4 nanophosphor (21 nm) has been synthesized via low temperature polyol route and subsequently thin films of the same were deposited on glass and ITO substrates by RF magnetron sputtering. The films were characterized by X-ray Diffraction and luminescence measurements. The XRD pattern showed that Tb3+ doped ZnGa2O4 nanophosphor has a cubic spinel phase. Luminescence behavior of the nanophosphor and as deposited sputtered film was investigated. The PL emission spectra of nanophosphor gave a broad ZnGa2O4 host emission band along with a strong terbium emission and the thin films showed only broad host emission band and there was no terbium ion emission.

  2. A "plug-and-play" approach to the preparation of transparent luminescent hybrid materials based on poly(methyl methacrylate), a calix[4]arene cross-linking agent, and terbium ions.

    Science.gov (United States)

    Driscoll, Christopher R; Reid, Brodie L; McIldowie, Matthew J; Muzzioli, Sara; Nealon, Gareth L; Skelton, Brian W; Stagni, Stefano; Brown, David H; Massi, Massimiliano; Ogden, Mark I

    2011-04-07

    A novel methodology to prepare transparent luminescent hybrid materials is reported. Using a calixarene ionophore as a PMMA cross-linker avoids problems, such as phase segregation, and produces a polymer monolith that can be loaded with the metal ion required for luminescence post-synthesis. This approach is versatile and will simplify the production of such materials.

  3. Raman spectroscopy study of the doping effect of the encapsulated terbium halogenides on single-walled carbon nanotubes

    Energy Technology Data Exchange (ETDEWEB)

    Kharlamova, M.V.; Kramberger, C.; Mittelberger, A. [University of Vienna, Faculty of Physics, Vienna (Austria)

    2017-04-15

    In the present work, the doping effect of terbium chloride, terbium bromide, and terbium iodide on single-walled carbon nanotubes (SWCNTs) was compared by Raman spectroscopy. A precise investigation of the doping-induced alterations of the Raman modes of the filled SWCNTs was conducted. The shifts of the components of the Raman modes and modification of their profiles allowed concluding that the inserted terbium halogenides have acceptor doping effect on the SWCNTs, and the doping efficiency increases in the line with terbium iodide, terbium bromide, and terbium chloride. (orig.)

  4. Thermoluminescence of cerium and terbium -doped calcium pyrophosphate

    Energy Technology Data Exchange (ETDEWEB)

    Roman L, J.; Cruz Z, E. [UNAM, Instituto de Ciencias Nucleares, Circuito Exterior, Ciudad Universitaria, 04510 Mexico D. F. (Mexico); Lozano R, I. B.; Diaz G, J. A. I., E-mail: jesus.roman@nucleares.unam.mx [IPN, Centro de Investigacion en Ciencia Aplicada y Tecnologia Avanzada, Av. Legaria No. 694, 11500 Mexico D. F. (Mexico)

    2015-10-15

    The aim of this work is to report the thermoluminescence (Tl) response of Calcium Pyrophosphate phosphor doped with Cerium and Terbium impurities (Ca{sub 2}P{sub 2}O{sub 7}:Ce{sup 3+},Tb{sup 3+}). The phosphors were synthesized using the co-precipitation method and annealed at 900 degrees C by two hours for obtain the β phase. The intentional doping with Ce and Tb ions was 1 at.% and 0.1 at.%, whereas in the EDS results the concentration of impurities was 0.39 at.% and 0.05 at.%, respectively. The superficial morphology of phosphor is mainly composed by thin wafers of different size. All samples were exposed to gamma rays from {sup 60}Co in the Gammacell-200 irradiator. The Tl response of the phosphor was measured from Rt up to 350 degrees C and under nitrogen atmosphere in a Harshaw TLD 3500 reader. The glow curves of the Ca{sub 2}P{sub 2}O{sub 7}:Ce{sup 3+},Tb{sup 3+} powders showed a broad intense Tl peak centered at 165 degrees C and a shoulder at approximate 260 degrees C was observed. A linear Tl response in the range of absorbed dose of 0.2 to 10 Gy was obtained. Tl glow curves were analyzed using the initial rise (IR)and computerized glow curve deconvolution methods to evaluate the kinetics parameters such as activation energy (E), frequency factor (s) and kinetic order (b). (Author)

  5. Magnetocaloric effect of thin Terbium films

    Science.gov (United States)

    Mello, V. D.; Anselmo, D. H. A. L.; Vasconcelos, M. S.; Almeida, N. S.

    2017-12-01

    We report a theoretical study of the magnetocaloric effect of Terbium (Tb) thin films due to finite size and surface effects in the helimagnetic phase, corresponding to a temperature range from TC=219 K to TN=231 K, for external fields of the order of kOe. For a Tb thin film of 6 monolayers submitted to an applied field (ΔH =30 kOe, ΔH =50 kOe and ΔH = 70 kOe) we report a significative change in adiabatic temperature, ΔT / ΔH , near the Néel temperature, of the order ten times higher than that observed for Tb bulk. On the other hand, for small values of the magnetic field, large thickness effects are found. For external field strength around few kOe, we have found that the thermal caloric efficiency increases remarkably for ultrathin films. For an ultrathin film with 6 monolayers, we have found ΔT / ΔH = 43 K/T while for thicker films, with 20 monolayers, ΔT / ΔH = 22 K/T. Our results suggest that thin films of Tb are a promising material for magnetocaloric effect devices for applications at intermediate temperatures.

  6. Femtosecond XUV spectroscopy of gadolinium and terbium

    Energy Technology Data Exchange (ETDEWEB)

    Carley, Robert; Frietsch, Bjoern; Doebrich, Kristian; Teichmann, Martin; Gahl, Cornelius; Noack, Frank [Max-Born-Institute, Berlin (Germany); Schwarzkopf, Olaf; Wernet, Philippe [Helmholtz-Zentrum fuer Materialien und Energie (BESSY II), Berlin (Germany); Weinelt, Martin [Max-Born-Institute, Berlin (Germany); Fachbereich Physik, Freie Universitaet, Berlin (Germany)

    2011-07-01

    We present recent results of time-resolved IR-pump-XUV-probe experiments on the ultrafast demagnetization of thin films of Gadolinium(0001) and Terbium(0001) on Tungsten(110). The experiments are the first to be done using a newly developed high-order harmonics (HHG) XUV beamline at the MBI. The beamline delivers monochromated XUV pulses of approximately 150 fs duration with a photon energy resolution of up to 150 meV. Following excitation by intense femtosecond infrared (IR) pulses, photoemission with 35 eV photons allows us to directly probe the 4f electrons and their interaction with the valence band, both in the bulk and at the surface, to follow the ultrafast magnetization dynamics in the Lanthanide metals. As signatures of ultrafast demagnetization of the metal by the IR pulse, we see for the first time, rapid strong reduction of the exchange splitting in the valence band. This is followed by a slower demagnetization due to the spin-lattice interaction.

  7. The influence of pressure on the photoluminescence properties of a terbium-adipate framework

    Science.gov (United States)

    Spencer, Elinor C.; Zhao, Jing; Ross, Nancy L.; Andrews, Michael B.; Surbella, Robert G.; Cahill, Christopher L.

    2013-06-01

    The influence of pressure (over the 0-4.7 GPa range) on the photoluminescence emissions and crystal structure of the known 3D terbium-adipate metal-organic framework material Tb-GWMOF6 has been evaluated by high-pressure single-crystal X-ray diffraction and spectroscopic techniques. The results from this study show that this complex lanthanide framework structure undergoes three phase transitions within the 0-4 GPa pressure range that involve alterations in the number of symmetry independent Tb3+ ion sites within the crystal lattice. These pressure induced modifications to the structure of Tb-GWMOF6 lead to pronounced changes in the profiles of the 5D4→7F5 emission spectra of this complex.

  8. Investigation of the luminescent properties of terbium-anthranilate complexes and application to the determination of anthranilic acid derivatives in aqueous solutions

    Energy Technology Data Exchange (ETDEWEB)

    Arnaud, N.; Georges, J

    2003-01-10

    The luminescent properties of terbium complexes with furosemide (FR), flufenamic (FF) acid, tolfenamic (TF) acid and mefenamic (MF) acid have been investigated in aqueous solutions. For all four compounds, complexation occurs when the carboxylic acid of the aminobenzoic group is dissociated and is greatly favoured in the presence of trioctylphosphine oxide as co-ligand and Triton X-100 as surfactant. Under optimum conditions, luminescence of the lanthanide ion is efficiently sensitised and the lifetime of the {sup 5}D{sub 4} resonance level of terbium in the complex is ranging between 1 and 1.9 ms, against 0.4 ms for the aqua ion. The sensitivity of the method for the determination of anthranilic acid derivatives is improved by one to two orders of magnitude with respect to that achieved using native fluorescence or terbium-sensitised luminescence in methanol. The limits of detection are 2x10{sup -10}, 5x10{sup -10} and 2x10{sup -9} mol l{sup -1} for flufenamic acid, furosemide and tolfenamic acid, and mefenamic acid, respectively, with within-run RSD values of less than 1%. The method has been applied to the determination of flufenamic acid in spiked calf sera with and without sample pretreatment. Depending on the method and the analyte concentration, the recovery was ranging between 83 and 113% and the lowest concentration attainable in serum samples was close to 1x10{sup -7} mol l{sup -1}.

  9. Luminescent investigations of terbium(III) biosorption as a surrogate for heavy metals and radionuclides.

    Science.gov (United States)

    Achyuthan, Komandoor E; Arango, Dulce C; Carles, Elizabeth L; Cutler, Christopher E; Meyer, Lauren A; Brozik, Susan M

    2009-07-01

    We describe a metal transport system for investigating the interfacial interactions between the anionic surface charge of a gram-negative bacterium (Escherichia coli) and a trivalent cationic metal, Tb3+. We believe this is the first description of the uptake kinetics, sub- and intracellular distribution, and temporal fate of Tb3+ ion in E. coli. We used the luminescence of the terbium-dipicolinic acid chelate to study metal ion transport. The bacteria had a high tolerance for the metal (IC(50) = 4 mM Tb3+). Metal ion transport was passive and metabolism independent. The uptake kinetics rapidly reached a maximum within 15 min, followed by a stasis for 60 min, and declining thereafter between 120 and 240 min, resulting in a biphasic curve. During this period, greater than one-third of the metal ion was sequestered within the cell. Our choice of a safe Biosafety Level I E. coli bacteria and the relatively non-toxic Tb3+ metal represents a model system for luminescent investigations of biosorption, for studying bacterial-water interfacial chemistry and for the bioremediation of heavy metals and radionuclides.

  10. Preparation and photoluminescence enhancement in terbium(III ternary complexes with β-diketone and monodentate auxiliary ligands

    Directory of Open Access Journals (Sweden)

    Devender Singh

    2016-12-01

    Full Text Available A series of new solid ternary complexes of terbium(III ion based on β-diketone ligand acetylacetone (acac and monodentate auxiliary ligands (aqua/urea/triphenylphosphineoxide/pyridine-N-oxide had been prepared. The structural characterizations of synthesized ternary compounds were studied by means of elemental analysis, infrared (IR, and proton nuclear magnetic resonance (NMR spectral techniques. The optical characteristics were investigated with absorption as well as photoluminescence spectroscopy. Thermal behavior of compounds was examined by TGA/DTA analysis and all metal complexes were found to have good thermal stability. The luminescence decay time of complexes were also calculated by monitoring at emission wavelength corresponding to 5D4 → 7F5 transition. A comparative inspection of the luminescent behavior of prepared ternary compounds was performed in order to determine the function of auxiliary ligands in the enhancement of luminescence intensity produced by central terbium(III ion. The color coordinates values suggested that compounds showed bright green emission in visible region in electromagnetic spectrum. Complexes producing green light could play a significant role in the fabrication of efficient light conversion molecular devices for display purposes and lightning systems.

  11. Terahertz Cherenkov radiation from ultrafast magnetization in terbium gallium garnet

    Science.gov (United States)

    Gorelov, S. D.; Mashkovich, E. A.; Tsarev, M. V.; Bakunov, M. I.

    2013-12-01

    We report an experimental observation of terahertz Cherenkov radiation from a moving magnetic moment produced in terbium gallium garnet by a circularly polarized femtosecond laser pulse via the inverse Faraday effect. Contrary to some existing theoretical predictions, the polarity of the observed radiation unambiguously demonstrates the paramagnetic, rather than diamagnetic, nature of the ultrafast inverse Faraday effect. From measurements of the radiation field, the Verdet constant in the subpicosecond regime is ˜3-10 times smaller than its table quasistatic value.

  12. A Nanoscale Multiresponsive Luminescent Sensor Based on a Terbium(III) Metal-Organic Framework.

    Science.gov (United States)

    Dang, Song; Wang, Ting; Yi, Feiyan; Liu, Qinghui; Yang, Weiting; Sun, Zhong-Ming

    2015-08-01

    A nanoscale terbium-containing metal-organic framework (nTbL), with a layer-like structure and [H2 NMe2 ](+) cations located in the framework channels, was synthesized under hydrothermal conditions. The structure of the as-prepared sample was systematically confirmed by powder XRD and elemental analysis; the morphology was characterized by field-emission SEM and TEM. The photoluminescence studies revealed that rod-like nTbL exhibited bright-green emission, corresponding to (5)D4 →(7)FJ (J=6-3) transitions of the Tb(3+) ion under excitation. Further sensing measurements revealed that as-prepared nTbL could be utilized as a multiresponsive luminescent sensor, which showed significant and exclusive detection ability for Fe(3+) ions and phenylmethanol. These results highlight the practical applications of lanthanide-containing metal-organic frameworks as fluorescent probes. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Influence of crystalline structure on the luminescence properties of terbium orthotantalates

    Energy Technology Data Exchange (ETDEWEB)

    Siqueira, Kisla P.F. [Departamento de Química, Universidade Federal de Ouro Preto, Campus Morro do Cruzeiro, ICEB II, Ouro Preto 35400-000, Minas Gerais (Brazil); Carmo, Alexandre P. [Instituto Federal Fluminense, Campus Cabo Frio, RJ 28909-971 (Brazil); Bell, Maria J.V. [Departamento de Física, Universidade Federal de Juiz de Fora, Juiz de Fora 36036-330, MG (Brazil); Dias, Anderson, E-mail: anderson_dias@iceb.ufop.br [Departamento de Química, Universidade Federal de Ouro Preto, Campus Morro do Cruzeiro, ICEB II, Ouro Preto 35400-000, Minas Gerais (Brazil)

    2013-06-15

    Terbium orthotantalate powders were produced with M-fergusonite type (I2/a) and M′-fergusonite type (P2/a) structures. The samples were studied by X-ray diffraction, Raman scattering, and photoluminescence measurements (emission and decay curves). The results showed that crystalline materials were obtained with all the 18 Raman-active modes predicted by group theory calculations. Also, it was observed through photoluminescence decay curves that the Tb{sup 3+} ions occupies only one-symmetry site in both crystallographic arrangements. Photoluminescence emission curves exhibited some variation in spectral shape, peak position, and relative intensity as a consequence of their different crystalline arrangements. The dominated emission of Tb{sup 3+} ({sup 5}D{sub 4}→{sup 7}F{sub 5}) is centered with a maximum intensity at 549.2 nm (M-type) and 543.0 nm (M′-type). Fluorescence lifetimes for M-TbTaO{sub 4} and M′-TbTaO{sub 4} were determined as 33.4 μs and 1.25 ms, respectively. M′-type materials seems to be the most suitable for luminescent devices and could be a potential green luminescent material due to the strongest emission if compared with the M-fergusonite type. -- Highlights: ► Terbium orthotantalates were prepared in two different crystalline structures: I2/a and P2/a. ► XRD and Raman scattering showed that the different space groups obtained were exhibited all the 18 Raman-active modes. ► PL decay curves that the Tb{sup 3+} ions occupies only one-symmetry site in both crystallographic arrangements. ► Dominated emission of Tb{sup 3+} ({sup 5}D{sub 4}→{sup 7}F{sub 5}) is centered with a maximum intensity at 549 nm (M-type) and 543 nm (M′-type). ► Fluorescence lifetimes for M-TbTaO{sub 4} and M′-TbTaO{sub 4} were determined as 33.4 μs and 1.25 ms, respectively.

  14. TOF SIMS analysis and generation of white photoluminescence from strontium silicate codoped with europium and terbium

    Energy Technology Data Exchange (ETDEWEB)

    Tshabalala, Modiehi A.; Swart, Hendrik C.; Ntwaeaborwa, Odireleng M., E-mail: ntwaeab@ufs.ac.za [Department of Physics, University of the Free State, P.O Box 339, Bloemfontein 9300 South Africa (South Africa)

    2014-03-15

    White light emitting terbium (Tb{sup 3+}) and europium (Eu{sup 3+}) codoped strontium silicate (Sr{sub 2}SiO{sub 4}) phosphors were prepared by a solid state reaction process. The structure, particle morphology, chemical composition, ion distribution, photoluminescence (PL), and decay characteristics of the phosphors were analyzed by x-ray diffraction (XRD), scanning electron microscopy (SEM), time-of-flight secondary ion mass spectrometry (TOF-SIMS), and PL spectroscopy, respectively. The XRD data showed that our Sr{sub 2}SiO{sub 4} composed of two phases, namely, β-Sr{sub 2}SiO{sub 4} and α′-Sr{sub 2}SiO{sub 4}, and the α′-Sr{sub 2}SiO{sub 4} phase was more prominent than the β-Sr{sub 2}SiO{sub 4} phase. The SEM micrographs showed that the particles were agglomerated together and they did not have definite shapes. All ions (i.e., negative and positive) present in our materials were identified by TOF-SIMS. In addition, the chemical imaging performed with the TOF-SIMS demonstrated how the individual ions including the dopants (Eu{sup 3+} and Tb{sup 3+}) were distributed in the host lattice. White photoluminescence was observed when the Sr{sub 2}SiO{sub 4}:Tb{sup 3+}, Eu{sup 3+} phosphor was excited at 239 nm using a monochromatized xenon lamp as the excitation source. The phosphor exhibited fast decay lifetimes implying that it is not a good candidate for long afterglow applications.

  15. Structural variations in terbium(III) complexes with 1,3-adamantanedicarboxylate and diverse co-ligands

    Energy Technology Data Exchange (ETDEWEB)

    Thuéry, Pierre, E-mail: pierre.thuery@cea.fr

    2015-07-15

    Terbium nitrate was reacted with 1,3-adamantanedicarboxylic acid (LH{sub 2}) under solvo-hydrothermal conditions with either N,N-dimethylformamide (DMF) or N,N-dimethylacetamide (DMA) as organic solvents. Hydrolysation of the latter co-solvents resulted in the formation of formate or acetate ions, which are present as co-ligands in the 1D coordination polymer [Tb(L)(HCOO)(H{sub 2}O){sub 2}] (1) and the 2D assembly [Tb(L)(CH{sub 3}COO)(H{sub 2}O)] (2). The increase in dimensionality in the latter arises from the higher connectivity provided by acetate versus formate, the L{sup 2−} ligand being bis-chelating in both cases. The complex [Tb{sub 2}(L){sub 3}(H{sub 2}O){sub 5}][Tb{sub 2}(L){sub 3}(H{sub 2}O){sub 4}]·3H{sub 2}O (3), another 1D species, crystallizes alongside crystals of 2. Further addition of cucurbit[6]uril (CB6), with DMF as co-solvent, gave the two complexes [Tb{sub 2}(L){sub 2}(CB6)(H{sub 2}O){sub 6}](NO{sub 3}){sub 2}·6H{sub 2}O (4) and [H{sub 2}NMe{sub 2}]{sub 2}[Tb(L)(HCOO){sub 2}]{sub 2}·CB6·3H{sub 2}O (5). Complex 4 crystallizes as a 3D framework in which Tb(L){sup +} chains are connected by tetradentate CB6 molecules, while 5 unites a carboxylate-bridged anionic 2D planar assembly and layers of CB6 molecules with counter-cations held at both portals. - Graphical abstract: One- to three-dimensional assemblies are formed in terbium(III) complexes with 1,3-adamantanedicarboxylate obtained under solvo-hydrothermal conditions, these species including formate or acetate co-ligands formed in situ, or additional cucurbit[6]uril molecules. - Highlights: • We report structures of terbium(III) complexes with 1,3-adamantanedicarboxylate. • Solvents able to generate co-ligands or counter-ions in situ have been used. • A 3D species including additional cucurbituril molecules is decribed. • One species displays an alternation of metal–organic and organic sheets.

  16. Terbium luminescence in alumina xerogel fabricated in porous anodic alumina matrix under various excitation conditions

    Energy Technology Data Exchange (ETDEWEB)

    Gaponenko, N. V., E-mail: nik@nano.bsuir.edu.by [Belarusian State University of Informatics and Radioelectronics (Belarus); Kortov, V. S. [Yeltsin Ural Federal University (Russian Federation); Orekhovskaya, T. I.; Nikolaenko, I. A. [Belarusian State University of Informatics and Radioelectronics (Belarus); Pustovarov, V. A.; Zvonarev, S. V.; Slesarev, A. I. [Yeltsin Ural Federal University (Russian Federation); Prislopski, S. Ya. [National Academy of Sciences of Belarus, Stepanov Institute of Physics (Belarus)

    2011-07-15

    Terbium-doped alumina xerogel layers are synthesized by the sol-gel method in pores of a porous anodic alumina film 1 {mu}m thick with a pore diameter of 150-180 nm; the film is grown on a silicon substrate. The fabricated structures exhibit terbium photoluminescence with bands typical of trivalent terbium terms. Terbium X-ray luminescence with the most intense band at 542 nm is observed for the first time for such a structure. Morphological analysis of the structure by scanning electron microscopy shows the presence of xerogel clusters in pore channels, while the main pore volume remains unfilled and pore mouths remain open. The data obtained confirm the promising applications of fabricated structures for developing matrix converters of X-rays and other ionizing radiations into visible light. The possibilities of increasing luminescence intensity in the matrix converter are discussed.

  17. Optical Properties of Lithium Terbium Fluoride and Implications for Performance in High Power Lasers (Postprint)

    Science.gov (United States)

    2016-02-01

    AFRL-RX-WP-JA-2016-0323 OPTICAL PROPERTIES OF LITHIUM TERBIUM FLUORIDE AND IMPLICATIONS FOR PERFORMANCE IN HIGH POWER LASERS... AMERICA (STINFO COPY) AIR FORCE RESEARCH LABORATORY MATERIALS AND MANUFACTURING DIRECTORATE WRIGHT-PATTERSON AIR FORCE BASE, OH 45433-7750 AIR...OPTICAL PROPERTIES OF LITHIUM TERBIUM FLUORIDE AND IMPLICATIONS FOR PERFORMANCE IN HIGH POWER LASERS (POSTPRINT) 5a. CONTRACT NUMBER IN-HOUSE 5b

  18. Detection of biothiols in cells by a terbium chelate-Hg (II) system

    Science.gov (United States)

    Tan, Hongliang; Chen, Yang

    2012-01-01

    Great efforts have been devoted to the development of sensitive and specific analysis methods for biothiols because of their important roles in biological systems. We present a new detection system for biothiols that is based on the reversible quenching and restoration of fluorescence of terbium chelate caused by Hg2+ and thiol species. In the presence of biothiols, a restoration of fluorescence of terbium chelate after quenching by Hg2+ was observed due to the interaction of Hg2+ with thiol groups, and the restored fluorescence increased with the concentration of biothiols. This method was sensitive and selective for biothiols. The detection limit was 80 nM for glutathione, 100 nM for Hcy, and 400 nM for Cysteine, respectively. The terbium chelate-Hg (II) system was successfully applied to determine the levels of biothiols in cancer cells and urine samples. Further, it was also shown to be comparable to Ellman's assay. Compared to other fluorescence methods, the terbium chelate probe is advantageous because interference from short-lived nonspecific fluorescence can be efficiently eliminated due to the long fluorescence lifetime of terbium chelate, which allows for detection by time-resolved fluorescence. The terbium chelate probe can serve as a diagnostic tool for the detection of abnormal levels of biothiols in disease.

  19. Crystal structures of two mononuclear complexes of terbium(III) nitrate with the tripodal alcohol 1,1,1-tris-(hy-droxy-meth-yl)propane.

    Science.gov (United States)

    Gregório, Thaiane; Giese, Siddhartha O K; Nunes, Giovana G; Soares, Jaísa F; Hughes, David L

    2017-02-01

    Two new mononuclear cationic complexes in which the TbIII ion is bis-chelated by the tripodal alcohol 1,1,1-tris-(hy-droxy-meth-yl)propane (H3LEt, C6H14O3) were prepared from Tb(NO3)3·5H2O and had their crystal and mol-ecular structures solved by single-crystal X-ray diffraction analysis after data collection at 100 K. Both products were isolated in reasonable yields from the same reaction mixture by using different crystallization conditions. The higher-symmetry complex dinitratobis[1,1,1-tris-(hy-droxy-meth-yl)propane]-terbium(III) nitrate di-meth-oxy-ethane hemisolvate, [Tb(NO3)2(H3LEt)2]NO3·0.5C4H10O2, 1, in which the lanthanide ion is 10-coordinate and adopts an s-bicapped square-anti-prismatic coordination geometry, contains two bidentate nitrate ions bound to the metal atom; another nitrate ion functions as a counter-ion and a half-mol-ecule of di-meth-oxy-ethane (completed by a crystallographic twofold rotation axis) is also present. In product aqua-nitratobis[1,1,1-tris-(hy-droxy-meth-yl)propane]-terbium(III) dinitrate, [Tb(NO3)(H3LEt)2(H2O)](NO3)2, 2, one bidentate nitrate ion and one water mol-ecule are bound to the nine-coordinate terbium(III) centre, while two free nitrate ions contribute to charge balance outside the tricapped trigonal-prismatic coordination polyhedron. No free water mol-ecule was found in either of the crystal structures and, only in the case of 1, di-meth-oxy-ethane acts as a crystallizing solvent. In both mol-ecular structures, the two tripodal ligands are bent to one side of the coordination sphere, leaving room for the anionic and water ligands. In complex 2, the methyl group of one of the H3LEt ligands is disordered over two alternative orientations. Strong hydrogen bonds, both intra- and inter-molecular, are found in the crystal structures due to the number of different donor and acceptor groups present.

  20. Cryogenic temperature characteristics of Verdet constant of terbium sesquioxide ceramics

    Science.gov (United States)

    Snetkov, I. L.; Palashov, O. V.

    2016-12-01

    The dependence of the Verdet constant on temperature in the (80-300 K) range for a promising magneto-active material terbium sesquioxide Tb2O3 at the wavelengths of 405-1064 nm is considered. For each of the studied wavelengths, the Verdet constant of the material cooled down to the liquid nitrogen temperature increased by more than a factor of 3.2 as compared to the room temperature value. Similarly to the other paramagnetics, the increase follows the law ∼1/T. Approximations for the temperature dependence of the Verdet constant have been obtained and the value of 1/V·(dV/dT) has been estimated. This information is needed to determine the angle of rotation as well as the variation of the extinction ratio of a Faraday isolator with temperature and extremely important at creation a cryogenic Faraday devices.

  1. Biogenic terbium oxide nanoparticles as the vanguard against osteosarcoma

    Science.gov (United States)

    Iram, Sana; Khan, Salman; Ansary, Abu Ayoobul; Arshad, Mohd; Siddiqui, Sahabjada; Ahmad, Ejaz; Khan, Rizwan H.; Khan, Mohd Sajid

    2016-11-01

    The synthesis of inner transition metal nanoparticles via an ecofriendly route is quite difficult. This study, for the first time, reports synthesis of terbium oxide nanoparticles using fungus, Fusarium oxysporum. The biocompatible terbium oxide nanoparticles (Tb2O3 NPs) were synthesized by incubating Tb4O7 with the biomass of fungus F. oxysporum. Multiple physical characterization techniques, such as UV-visible and photoluminescence spectroscopy, TEM, SAED, and zeta-potential were used to confirm the synthesis, purity, optical and surface characteristics, crystallinity, size, shape, distribution, and stability of the nanoemulsion of Tb2O3 NPs. The Tb2O3 NPs were found to inhibit the propagation of MG-63 and Saos-2 cell-lines (IC50 value of 0.102 μg/mL) and remained non-toxic up to a concentration of 0.373 μg/mL toward primary osteoblasts. Cell viability decreased in a concentration-dependent manner upon exposure to 10 nm Tb2O3 NPs in the concentration range 0.023-0.373 μg/mL. Cell toxicity was evaluated by observing changes in cell morphology, cell viability, oxidative stress parameters, and FACS analysis. Morphological examinations of cells revealed cell shrinkage, nuclear condensation, and formation of apoptotic bodies. The level of ROS within the cells-an indicator of oxidative stress was significantly increased. The induction of apoptosis at concentrations ≤ IC50 was corroborated by 4‧,6-diamidino-2-phenylindole dihydrochloride (DAPI) staining (DNA damage and nuclear fragmentation). Flow-cytometric studies indicated that the response was dose dependent with a threshold effect.

  2. Evidence of mass exchange between inside and outside of sonoluminescing bubble in aqueous solution of terbium chloride

    Energy Technology Data Exchange (ETDEWEB)

    Liang, Jinfu, E-mail: liang.shi2007@163.com [School of Physics and Electronic Science, Guizhou Normal University, Guiyang 550001 (China); Chen, Weizhong, E-mail: wzchen@nju.edu.cn [The Key Laboratory of Modern Acoustics, Ministry of Education, Institution of Acoustics, Nanjing University, Nanjing 210093 (China); Wang, Xun; Yang, Jing; Chen, Zhan [The Key Laboratory of Modern Acoustics, Ministry of Education, Institution of Acoustics, Nanjing University, Nanjing 210093 (China)

    2016-12-16

    Highlights: • Time-resolved spectra of SBSL were obtained for Tb{sup 3+} ions emission lines. • Mass exchange between inside and outside of SL bubble was probed via Tb{sup 3+} ions lines. • The argon rectification hypothesis was tested by time-resolved spectra of SBSL. • The rate of mass exchange inside an SBSL bubble increases with increasing sound pressure. - Abstract: Spectra of single-bubble sonoluminescence (SBSL) were obtained for Tb{sup 3+} ions emission lines from bubbles in an aqueous solution of terbium chloride (TbCl{sub 3}). The spectra provide experimental evidence to prove that an air bubble driven by strong ultrasound will not eventually become a rectified pure argon bubble, which is not as predicted by the argon rectification hypothesis. The time-resolved spectra of SBSL show a mass exchange of material such as Tb{sup 3+} ions between the inside and outside of the bubble. With increasing sound pressure, the rate of mass exchange and the SBSL intensity increases.

  3. Structural investigation and photoluminescent properties of gadolinium(III), europium(III) and terbium(III) 3-mercaptopropionate complexes.

    Science.gov (United States)

    Souza, E R; Mazali, I O; Sigoli, F A

    2014-01-01

    This work reports on the synthesis, crystallographic determination and spectroscopic characterization of gadolinium(III), terbium(III) and europium(III) 3-mercaptopropionate complexes, aqua-tris(3-mercaptopropionate)lanthanide(III)--[Ln(mpa)3(H2O)]. The Judd-Ofelt intensity parameters were experimentally determined from emission spectrum of the [Eu(mpa)3(H2O)]complex and they were also calculated from crystallographic data. The complexes are coordination polymers, where the units of each complex are linked together by carboxylate groups leading to an unidimensional and parallel chains that by chemical interactions form a tridimensional framework. The emission spectrum profile of the [Eu(mpa)3(H2O)] complex is discussed based on point symmetry of the europium(III) ion, that explains the bands splitting observed in its emission spectrum. Photoluminescent analysis of the [Gd(mpa)3(H2O)] complex show no efficient ligand excitation but an intense charge transfer band. The excitation spectra of the [Eu(mpa)3(H2O)] and [Tb(mpa)3(H2O)] complexes do not show evidence of energy transfer from the ligand to the excited levels of these trivalent ions. Therefore the emission bands are originated only by direct f-f intraconfigurational excitation of the lantanide(III) ions.

  4. Synthesis and luminescent study of Ce{sup 3+}-doped terbium-yttrium aluminum garnet

    Energy Technology Data Exchange (ETDEWEB)

    Dotsenko, V.P., E-mail: ssclab@ukr.net [A.V. Bogatsky Physico-Chemical Institute, National Academy of Sciences of Ukraine, Lustdorfskaya doroga 86, 65080 Odessa (Ukraine); Berezovskaya, I.V.; Zubar, E.V.; Efryushina, N.P. [A.V. Bogatsky Physico-Chemical Institute, National Academy of Sciences of Ukraine, Lustdorfskaya doroga 86, 65080 Odessa (Ukraine); Poletaev, N.I.; Doroshenko, Yu.A. [Institute of Combustion and Advanced Technologies, Mechnikov Odessa National University, Dvoryanskaya 2, 65082 Odessa (Ukraine); Stryganyuk, G.B. [Ivan Franko National University of Lviv, Kirilo i Mefodii 8, 79005 Lviv (Ukraine); HASYLAB at DESY, Notkestrasse 85, 22607 Hamburg (Germany); Voloshinovskii, A.S. [Ivan Franko National University of Lviv, Kirilo i Mefodii 8, 79005 Lviv (Ukraine)

    2013-02-15

    Highlights: Black-Right-Pointing-Pointer Ce{sup 3+}-doped garnets (TYAG) were prepared using nanostructured reagents. Black-Right-Pointing-Pointer The Ce{sup 3+} ions cause a very efficient yellow emission of the samples. Black-Right-Pointing-Pointer The reasons for the long wavelength position of this emission are discussed. Black-Right-Pointing-Pointer Contribution from Al atoms to the conduction band of TYAG is quite essential. - Abstract: Terbium-yttrium aluminum garnets (TYAG) doped with Ce{sup 3+} ions have been prepared by solid state reactions between nanostructured oxides of aluminum and rare earths. The luminescent properties of Ce{sup 3+} ions in (Tb{sub 0.8}Y{sub 0.2}){sub 3(1-x)}Ce{sub 3x}Al{sub 5}O{sub 12} (x = 0.03) have been studied upon excitation in the 2-20 eV region. The substitution of Tb{sup 3+} for Y{sup 3+} in the garnet structure results in broadening the emission band and shifting its maximum towards the longer wavelengths. It was found that in addition to the 4f{sup n} {yields} 4f{sup n-1}5d excitation bands of Ce{sup 3+} and Tb{sup 3+} ions, the excitation spectra for the Ce{sup 3+} emission contain broad bands at 6.73 and {approx}9.5 eV. These bands are attributed to the Ce{sup 3+}-bound exciton formation and O 2p {yields} Al 3s, 3p transitions, respectively. In contrast to the predictions based on the results of electronic structure calculations on Y{sub 3}Al{sub 5}O{sub 12} and Tb{sub 4}Al{sub 2}O{sub 9}, the threshold of interband transitions in TYAG is at high energies ( Greater-Than-Or-Slanted-Equal-To 7.3 eV), and contributions from Al{sub tetr} and Al{sub oct} atoms to the conduction-band density of states are evaluated as quite essential.

  5. Autofluorescence-free Live-cell Imaging Using Terbium Nanoparticles.

    Science.gov (United States)

    Cardoso Dos Santos, Marcelina; Goetz, Joan; Bartenlian, Hortense; Wong, Ka-Leung; Charbonniere, Loïc Joanny; Hildebrandt, Niko

    2018-02-20

    Fluorescent nanoparticles (NPs) have become irreplaceable tools for advanced cellular and sub-cellular imaging. While very bright NPs require excitation with UV or visible light, which can create strong autofluorescence of biological components, NIR-excitable NPs without autofluorescence issues exhibit much lower brightness. Here, we show the application of a new type of surface-photosensitized terbium NPs (Tb-NPs) for autofluorescence-free intracellular imaging in live HeLa cells. Combination of exceptionally high brightness, high photostability, and long photoluminecence (PL) lifetimes for highly efficient suppression of the short-lived autofluorescence, allowed for time-gated PL imaging of intracellular vesicles over 72 h without toxicity and at extremely low Tb-NP concentrations down to 12 pM. Detection of highly resolved long-lifetime (ms) PL decay curves from small (~10 µm2) areas within single cells within a few seconds emphasized the unprecedented photophysical properties of Tb-NPs for live-cell imaging that extend well beyond currently available nanometric imaging agents.

  6. Solar Thermochemical Hydrogen Production via Terbium Oxide Based Redox Reactions

    Directory of Open Access Journals (Sweden)

    Rahul Bhosale

    2016-01-01

    Full Text Available The computational thermodynamic modeling of the terbium oxide based two-step solar thermochemical water splitting (Tb-WS cycle is reported. The 1st step of the Tb-WS cycle involves thermal reduction of TbO2 into Tb and O2, whereas the 2nd step corresponds to the production of H2 through Tb oxidation by water splitting reaction. Equilibrium compositions associated with the thermal reduction and water splitting steps were determined via HSC simulations. Influence of oxygen partial pressure in the inert gas on thermal reduction of TbO2 and effect of water splitting temperature (TL on Gibbs free energy related to the H2 production step were examined in detail. The cycle (ηcycle and solar-to-fuel energy conversion (ηsolar-to-fuel efficiency of the Tb-WS cycle were determined by performing the second-law thermodynamic analysis. Results obtained indicate that ηcycle and ηsolar-to-fuel increase with the decrease in oxygen partial pressure in the inert flushing gas and thermal reduction temperature (TH. It was also realized that the recuperation of the heat released by the water splitting reactor and quench unit further enhances the solar reactor efficiency. At TH=2280 K, by applying 60% heat recuperation, maximum ηcycle of 39.0% and ηsolar-to-fuel of 47.1% for the Tb-WS cycle can be attained.

  7. Folate Receptor Targeted Alpha-Therapy Using Terbium-149

    CERN Document Server

    Müller, Cristina; Haller, Stephanie; Dorrer, Holger; Köster, Ulli; Johnston, Karl; Zhernosekov, Konstantin; Türler, Andreas; Schibli, Roger

    2014-01-01

    Terbium-149 is among the most interesting therapeutic nuclides for medical applications. It decays by emission of short-range α-particles (Eα = 3.967 MeV) with a half-life of 4.12 h. The goal of this study was to investigate the anticancer efficacy of a 149Tb-labeled DOTA-folate conjugate (cm09) using folate receptor (FR)-positive cancer cells in vitro and in tumor-bearing mice. 149Tb was produced at the ISOLDE facility at CERN. Radiolabeling of cm09 with purified 149Tb resulted in a specific activity of ~1.2 MBq/nmol. In vitro assays performed with 149Tb-cm09 revealed a reduced KB cell viability in a FR-specific and activity concentration-dependent manner. Tumor-bearing mice were injected with saline only (group A) or with 149Tb-cm09 (group B: 2.2 MBq; group C: 3.0 MBq). A significant tumor growth delay was found in treated animals resulting in an increased average survival time of mice which received 149Tb-cm09 (B: 30.5 d; C: 43 d) compared to untreated controls (A: 21 d). Analysis of blood parameters rev...

  8. Hardness and dielectric characteristics of flux grown terbium aluminate crystals

    Energy Technology Data Exchange (ETDEWEB)

    Sharma, K.K.; Kotru, P.N. [Jammu Univ. (India). Dept. of Physics; Tandon, R.P. [National Physical Laboratory, New Delhi (India); Wanklyn, B.M. [Clarendon Laboratory, University of Oxford, Oxford (United Kingdom)

    1999-01-29

    Results of indentation induced Vickers hardness testing and dielectric studies conducted on flux-grown terbium aluminate crystals are presented. It is shown that the Vickers hardness value (H{sub v}) is independent of indentation time, but depends on the applied load. Applying the concept of Hays and Kendall, the load independent values are estimated for (110) and (001) planes. Differential behaviour in the crack formation of two different planes (110) and (001) is observed, while (001) plane develops Palmqvist cracks in the whole load range of 10-100 g, (110) plane shows a transition from Palmqvist to median cracks at 70 g. The fracture toughness, brittleness index and yield strength are determined for both the planes. The hardness anisotropy is reported. The dielectric constant, dielectric loss and conductivity are shown to be dependent on temperature and frequency of the applied a.c. field. The dielectric constant versus temperature shows a transition peak at 230 C, which remains independent of the frequency of the applied a.c. field in the range 1 kHz-13 MHz. (orig.) 36 refs.

  9. Highly luminescent charge-neutral europium(iii) and terbium(iii) complexes with tridentate nitrogen ligands.

    Science.gov (United States)

    Senthil Kumar, Kuppusamy; Schäfer, Bernhard; Lebedkin, Sergei; Karmazin, Lydia; Kappes, Manfred M; Ruben, Mario

    2015-09-21

    We report on the synthesis of tridentate-nitrogen pyrazole-pyridine-tetrazole (L(1)H) and pyrazole-pyridine-triazole (L(2)H) ligands and their complexation with lanthanides (Ln = Gd(iii), Eu(iii) and Tb(iii)) resulting in stable, charge-neutral complexes Ln(L(1))3 and Ln(L(2))3, respectively. X-ray crystallographic analysis of the complexes with L(1) ligands revealed tricapped trigonal coordination geometry around the lanthanide ions. All complexes show bright photoluminescence (PL) in the solid state, indicating efficient sensitization of the lanthanide emission via the triplet states of the ligands. In particular, the terbium complexes show high PL quantum yields of 65 and 59% for L(1) and L(2), respectively. Lower PL efficiencies of the europium complexes (7.5 and 9%, respectively) are attributed to large energy gaps between the triplet states of the ligands and accepting levels of Eu(iii). The triplet state energy can be reduced by introducing an electron withdrawing (EW) group at the 4 position of the pyridine ring. Such substitution of L(1)H with a carboxylic ester (COOMe) EW group leads to a europium complex with increased PL quantum yield of 31%. A comparatively efficient PL of the complexes dissolved in ethanol indicates that the lanthanide ions are shielded against nonradiative deactivation via solvent molecules.

  10. Solvent polarity and oxygen sensitivity, rather than viscosity, determine lifetimes of biaryl-sensitised terbium luminescence.

    Science.gov (United States)

    Walter, Edward R H; Williams, J A Gareth; Parker, David

    2017-12-14

    In a macrocyclic terbium complex incorporating a biaryl sensitiser, the observed variation of emission lifetime is shown to be determined by the solubility of oxygen in the solvent system and the relative energy of the chromophore excited state, rather than any dependence on solvent viscosity.

  11. The response behavior of PPy-DB18C6 electrode to terbium(III in acetonitrile and its thermodynamic application

    Directory of Open Access Journals (Sweden)

    Mohammad Hossein Arbab Zavar

    2016-11-01

    Full Text Available Polypyrrole modified electrode prepared by electropolymerization of pyrrole in the presence of a complexing ligand, dibenzo-18-crown-6(DB18C6, was prepared and investigated as a Tb3+-selective electrode in acetonitrile. The potentiometric response of the electrode was linear within the Tb3+ concentration range 1 × 10−5–1 × 10−2 M with a Nernstian slope of 20.9 mVdecade−1 in AN. The electrode was applied to study the complexation of the terbium(III ion in acetonitrile with such other basic aprotic solvent molecules (D as dimethyl sulfoxide, N,N-dimethyl formamide, propylene carbonate and pyridine. The successive complex formation constant (βi and Gibbs energies of transfer (ΔGtr of Tb3+ in AN in relation to such D were obtained.

  12. Luminescence and Magnetic Properties of Two Three-Dimensional Terbium and Dysprosium MOFs Based on Azobenzene-4,4′-Dicarboxylic Linker

    Directory of Open Access Journals (Sweden)

    Belén Fernández

    2016-02-01

    Full Text Available We report the in situ formation of two novel metal-organic frameworks based on terbium and dysprosium ions using azobenzene-4,4′-dicarboxylic acid (H2abd as ligand, synthesized by soft hydrothermal routes. Both materials show isostructural three-dimensional networks with channels along a axis and display intense photoluminescence properties in the solid state at room temperature. Textural properties of the metal-organic frameworks (MOFs have been fully characterized although no appreciable porosity was obtained. Magnetic properties of these materials were studied, highlighting the dysprosium material displays slightly frequency-dependent out of phase signals when measured under zero external field and under an applied field of 1000 Oe.

  13. Study of quantum dot based on tin/yttrium mixed oxide doped with terbium to be used as biomarker

    Energy Technology Data Exchange (ETDEWEB)

    Paganini, Paula P.; Felinto, Maria Claudia F.C.; Kodaira, Claudia A., E-mail: paulapaganini@usp.b, E-mail: mfelinto@ipen.b, E-mail: claudiakodaira@yahoo.co [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Brito, Hermi F., E-mail: hefbrito@iq.usp.b [Universidade de Sao Paulo (USP), SP (Brazil). Inst. de Quimica. Lab. de Elementos do Bloco f; Nunes, Luiz Antonio O., E-mail: luizant@ifsc.usp.b [Universidade de Sao Paulo (USP), Sao Carlos, SP (Brazil). Inst. de Fisica. Dept. de Fisica e Informatica

    2009-07-01

    Quantum dots (semiconductors nanocrystals) have brought a promising field to develop a new generation of luminescent biomarkers. The use of lanthanides ions as luminescent markers has many advantages, for example a security method, low cost, high specificity and also the luminescence can be promptly measured with high sensibility and accuracy. These luminescent dots are functionalized with biomolecules. For the luminophore particle to be connect with biologicals molecules (for example covalent antibody) is necessary a previous chemical treatment to modify luminophore particle surface and this process is called functionalization. A prior chemical treatment with changes on the surface luminophore particle is necessary to couple the luminophore to biological molecules. This process can be used as coating which can protect these particles from being dissolved by acid as well as provide functional groups for biological conjugation. This work presents a photoluminescence study of nanoparticles based on tin/yttrium mixed oxides doped with terbium (SnO{sub 2}/Y{sub 2}O{sub 3}:Tb{sup 3+}), synthesized by coprecipitation method. The nanoparticles were submitted to thermal treatment and characterized by X-Ray Powder Diffraction (XRD) that showed cassiterite phase formation and the influence of thermal treatment on nanoparticles structures. These nanoparticles going to be functionalized with a natural polysaccharide (chitosan) in order to form microspheres. These microspheres going to be irradiated with gamma radiation to sterilization and it can be evaluated if the nanoparticles are resistant to irradiation and they do not lose functionality with this process. (author)

  14. Comparative analysis of conjugated alkynyl chromophore-triazacyclononane ligands for sensitized emission of europium and terbium.

    Science.gov (United States)

    Soulié, Marine; Latzko, Frédéric; Bourrier, Emmanuel; Placide, Virginie; Butler, Stephen J; Pal, Robert; Walton, James W; Baldeck, Patrice L; Le Guennic, Boris; Andraud, Chantal; Zwier, Jurriaan M; Lamarque, Laurent; Parker, David; Maury, Olivier

    2014-07-07

    A series of europium and terbium complexes based on a functionalized triazacyclononane carboxylate or phosphinate macrocyclic ligand is described. The influence of the anionic group, that is, carboxylate, methylphosphinate, or phenylphosphinate, on the photophysical properties was studied and rationalized on the basis of DFT calculated structures. The nature, number, and position of electron-donating or electron-withdrawing aryl substituents were varied systematically within the same phenylethynyl scaffold in order to optimize the brightness of the corresponding europium complexes and investigate their two-photon absorption properties. Finally, the europium complexes were examined in cell-imaging applications, and selected terbium complexes were studied as potential oxygen sensors. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Spectrofluorimetric Determination of Human Serum Albumin Using Terbium-Danofloxacin Probe

    OpenAIRE

    Ramezani, Amir M.; Manzoori, Jamshid L.; Amjadi, Mohammad; Jouyban, Abolghasem

    2012-01-01

    A spectrofluorimetric method is proposed for the determination of human serum albumin (HSA) and bovine serum albumin (BSA) using terbium-danofloxacin (Tb3+-Dano) as a fluorescent probe. These proteins remarkably enhance the fluorescence intensity of the Tb3+-Dano complex at 545 nm, and the enhanced fluorescence intensity of Tb3+-Dano is proportional to the concentration of proteins (HSA and BSA). Optimum conditions for the determination of HSA were investigated and found that the maximum resp...

  16. Green light emission in aluminum oxide powders doped with different terbium concentrations

    Energy Technology Data Exchange (ETDEWEB)

    Mariscal B, L; Falcony, C. [IPN, Centro de Investigacion y de Estudios Avanzados, 07360 Ciudad de Mexico (Mexico); Carmona T, S.; Murrieta, H.; Sanchez A, M. A. [UNAM, Instituto de Fisica, 04510 Ciudad de Mexico (Mexico); Vazquez A, R. [IPN, Escuela Superior de Computo, 07738 Ciudad de Mexico (Mexico); Garcia R, C. M., E-mail: mariscal2005@gmail.com [UNAM, Facultad de Ciencias, 04510 Ciudad de Mexico (Mexico)

    2016-11-01

    Different emission intensities presented in aluminum oxide phosphors corresponding to different concentrations of doping performed with terbium are analyzed. The phosphors were synthesized by the evaporation technique and were characterized by photo and cathodoluminescence, X-ray diffraction and EDS techniques for different incorporation percentages of terbium as dopant; they show characteristic transitions in 494, 543, 587 and 622 nm, corresponding to {sup 5}D{sub 4} → {sup 7}F{sub 6}, {sup 5}D{sub 4} → {sup 7}F{sub 5}, {sup 5}D{sub 4} → {sup 7}F{sub 4} and {sup 5}D{sub 4} → {sup 7}F{sub 3}, respectively when they are excited with λ{sub exc} = 380 nm wavelength at room temperature. The results of X-ray diffraction show the presence of α-Al{sub 2}O{sub 3} phases with peaks located at 2θ = 25.78, 35.34, 37.96, 43.56, 45.8, 52.74, 57.7, 61.5, 66.74, 68.44, 77.12 and 80.94, and the δ-Al{sub 2}O-3 phase 2θ = 32.82, 45.8, 61.36 and 66.74. These compounds were heat treated for two hours at 1100 degrees Celsius. EDS analyzes indicate that these compounds have close to 60% oxygen around of 40% aluminum in the presence of terbium as dopant which indicates a stoichiometry close to the expected one for alumina. (Author)

  17. Fluorescence study of some terbium-oligopeptide complexes in methanolic solution.

    Science.gov (United States)

    Rabouan, S; Delage, J; Durand, W; Prognon, P; Barthes, D

    2000-04-03

    This study concerned the use of lanthanide chelates to detect glycyl-leucyl-phenylalanine (GLF) and its homologues. Spectroscopic analysis of peptides without or with terbium complexation revealed the formation of (LF)(3)(Tb)(2), (GF)(3)(Tb)(2), (GLF)(3)(Tb)(2) and (FL)(4)Tb, (FG)(4)Tb complexes with high stability constants in methanolic solutions (pK(d)>13). Lanthanide chelate emission displayed a large Stokes shift (>270 nm), which allowed Tb chelates of GLF and its derivatives to be used for detection purposes. However, this preliminary study indicated some important limitations associated with lanthanide chelation, such as high methanolic content.

  18. Electromagnetic properties of terbium gallium garnet at millikelvin temperatures and low photon energy

    Science.gov (United States)

    Kostylev, Nikita; Goryachev, Maxim; Bushev, Pavel; Tobar, Michael E.

    2017-07-01

    Electromagnetic properties of single crystal terbium gallium garnet are characterised from room down to millikelvin temperatures using the whispering gallery mode method. Microwave spectroscopy is performed at low powers equivalent to a few photons in energy and conducted as functions of the magnetic field and temperature. A phase transition is detected close to the temperature of 3.5 K. This is observed for multiple whispering gallery modes causing an abrupt negative frequency shift and a change in transmission due to extra losses in the new phase caused by a change in complex magnetic susceptibility.

  19. Nuclear excitation functions from 40 to 200 MeV proton irradiation of terbium

    Energy Technology Data Exchange (ETDEWEB)

    Engle, Jonathan W., E-mail: jwengle@lanl.gov; Mashnik, Stepan G.; Parker, Lauren A.; Jackman, Kevin R.; Bitteker, Leo J.; Ullmann, John L.; Gulley, Mark S.; Pillai, Chandra; John, Kevin D.; Birnbaum, Eva R.; Nortier, Francois M.

    2016-01-01

    Nuclear formation cross sections are reported for 26 radionuclides, measured with 40–200 MeV proton irradiations of terbium foils. These data provide the basis for the production of medically relevant radionuclides (e.g., {sup 152}Tb, {sup 155}Tb, {sup 155}Eu, and {sup 156}Eu) and {sup 153}Gd, a potential source used in ongoing efforts to characterize stellar nucleosynthesis routes. Computational predictions from the ALICE2011, CEM03.03, Bertini, and INCL + ABLA codes are compared with newly measured data to contribute to the ongoing process of code development, and yields are calculated for selected radionuclides using measured data.

  20. Micelle-enhanced and terbium-sensitized spectrofluorimetric determination of gatifloxacin and its interaction mechanism

    Science.gov (United States)

    Guo, Changchuan; Wang, Lei; Hou, Zhun; Jiang, Wei; Sang, Lihong

    2009-05-01

    A terbium-sensitized spectrofluorimetric method using an anionic surfactant, sodium dodecyl benzene sulfonate (SDBS), was developed for the determination of gatifloxacin (GFLX). A coordination complex system of GFLX-Tb 3+-SDBS was studied. It was found that SDBS significantly enhanced the fluorescence intensity of the complex (about 11-fold). Optimal experimental conditions were determined as follows: excitation and emission wavelengths of 331 and 547 nm, pH 7.0, 2.0 × 10 -4 mol l -1 terbium (III), and 2.0 × 10 -4 mol l -1 SDBS. The enhanced fluorescence intensity of the system (Δ If) showed a good linear relationship with the concentration of GFLX over the range of 5.0 × 10 -10 to 5.0 × 10 -8 mol l -1 with a correlation coefficient of 0.9996. The detection limit (3 σ) was determined as 6.0 × 10 -11 mol l -1. This method has been successfully applied to the determination of GFLX in pharmaceuticals and human urine/serum samples. Compared with most of other methods reported, the rapid and simple procedure proposed in the text offers higher sensitivity, wider linear range, and better stability. The interaction mechanism of the system is also studied by the research of ultraviolet absorption spectra, surface tension, solution polarity and fluorescence polarization.

  1. Circularly Polarized Luminescence in Enantiopure Europium and Terbium Complexes with Modular, All-Oxygen Donor Ligands

    Science.gov (United States)

    Seitz, Michael; Do, King; Ingram, Andrew J.; Moore, Evan G.; Muller, Gilles; Raymond, Kenneth N.

    2009-01-01

    Abstract: Circulaly polarized luminescence from terbium(III) complexed and excited by chiral antenna ligands gives strong emission The modular synthesis of three new octadentate, enantiopure ligands are reported - one with the bidentate chelating unit 2-hydroxyisophthalamide (IAM) and two with 1-hydroxy-2-pyridinone (1,2-HOPO) units. A new design principle is introduced for the chiral, non-racemic hexamines which constitute the central backbones for the presented class of ligands. The terbium(III) complex of the IAM ligand, as well as the europium(III) complexes of the 1,2-HOPO ligands are synthesized and characterized by various techniques (NMR, UV, CD, luminescence spectroscopy). All species exhibit excellent stability and moderate to high luminescence efficiency (quantum yields ΦEu = 0.05–0.08 and ΦTb = 0.30–0.57) in aqueous solution at physiological pH. Special focus is put onto the properties of the complexes in regard to circularly polarized luminescence (CPL). The maximum luminescence dissymmetry factors (glum) in aqueous solution are high with |glum|max = 0.08 – 0.40. Together with the very favorable general properties (good stability, high quantum yields, long lifetimes), the presented lanthanide complexes can be considered as good candidates for analytical probes based on CPL in biologically relevant environments. PMID:19639983

  2. Luminescent method of determination of composition of europium and terbium complexes in solution by change of intensity ratio of luminescence bands

    Energy Technology Data Exchange (ETDEWEB)

    Bel' tyukova, S.V.; Nazarenko, N.A.; Poluehktov, N.S.

    1982-03-01

    The complexes of europium and terbium with phenanthroline, ethylenediaminetetraacetate, nitrilotriacetate, some acids-phenol derivatives and ..beta..-diketones series have been used as an example to demonstrate that the value of the ratio of intensities on the two bands of europium(terbium) luminescence spectra - the one corresponding to the hypersensitive'' transition and the other, to the magnetic dipole one - can be used for determination of the complexes composition in solutions.

  3. Synthesis and photoluminescence properties of cerium-doped terbium-yttrium aluminum garnet phosphor for white light-emitting diodes applications

    Science.gov (United States)

    Wang, Jun; Han, Tao; Lang, Tianchun; Tu, Mingjing; Peng, Lingling

    2015-11-01

    Cerium-doped terbium-yttrium aluminum garnet phosphors were synthesized using the solid-state reaction method. The crystalline phase, morphology, and photoluminescence properties were characterized by x-ray diffraction (XRD), scanning electron microscope (SEM), and fluorescence spectrophotometer, respectively. The XRD results indicate that with an increase of the amount of x (Tb3+), all of the samples have a pure garnet crystal structure without secondary phases. The SEM images reveal that the samples are composed of sphere-like crystallites, which exhibit different degrees of agglomeration. The luminescent properties of Ce ions in )Al5O12∶Ce0.1 have been studied, and it was found that the emission band shifted toward a longer wavelength. The redshift is attributed to the lowering of the 5d energy level centroid of Ce, which can be explained by the nephelauxetic effect and compression effect. These phosphors were coated on blue light-emitting diode (LED) chips to fabricate white light-emitting diodes (WLEDs), and their color-rendering indices, color temperatures, and luminous efficiencies were measured. As a consequence of the addition of Tb, the blue LED pumped )Al5O12∶Ce0.1 phosphors WLEDs showed good optical properties.

  4. Study on the fluorescent enhancement effect in terbium-gadolinium-protein-sodium dodecyl benzene sulfonate system and its application on sensitive detection of protein at nanogram level.

    Science.gov (United States)

    Sun, Changxia; Yang, Jinghe; Wu, Xia; Liu, Shufang; Su, Benyu

    2004-08-01

    The co-luminescence effect in a terbium-gadolinium-protein-sodium dodecyl benzene sulfonate (SDBS) system is reported here. Based on it, the sensitive quantitative analysis of protein at nanogram levels is established. The co-luminescence mechanism is studied using fluorescence, resonance light scattering (RLS), absorption spectroscopy and NMR measurement. It is considered that protein could be unfolded by SDBS, then a efficacious intramolecular fluorescent energy transfer occurs from unfolded protein to rare earth ions through SDBS acting as a "transfer bridge" to enhance the emission fluorescence of Tb3+ in this ternary complex of Tb-SDBS-BSA, where energy transfer from protein to SDBS by aromatic ring stacking is the most important step. Cooperating with the intramolecular energy transfer above is the intermolecular energy transfer between the simultaneous existing complexes of both Tb3+ and Gd3+. The fluorescence quantum yield is increased by an energy-insulating sheath, which is considered to be another reason for the resulting enhancement of the fluorescence. Förster theory is used to calculate the distribution of enhancing factors and has led to a greater understanding of the mechanisms of energy transfer.

  5. The effect of core and lanthanide ion dopants in sodium fluoride-based nanocrystals on phagocytic activity of human blood leukocytes

    Science.gov (United States)

    Sojka, Bartlomiej; Liskova, Aurelia; Kuricova, Miroslava; Banski, Mateusz; Misiewicz, Jan; Dusinska, Maria; Horvathova, Mira; Ilavska, Silvia; Szabova, Michaela; Rollerova, Eva; Podhorodecki, Artur; Tulinska, Jana

    2017-02-01

    Sodium fluoride-based β-NaLnF4 nanoparticles (NPs) doped with lanthanide ions are promising materials for application as luminescent markers in bio-imaging. In this work, the effect of NPs doped with yttrium (Y), gadolinium (Gd), europium (Eu), thulium (Tm), ytterbium (Yb) and terbium (Tb) ions on phagocytic activity of monocytes and granulocytes and the respiratory burst was examined. The surface functionalization of leukocytes and respiratory burst of cells was observed for limited number of samples.

  6. Thermo-transferred thermoluminescence (TTTl) in potassium-yttrium double fluoride doped with terbium

    Energy Technology Data Exchange (ETDEWEB)

    Gallegos, A.; Rivera, T.; Diaz G, J. A. [IPN, Centro de Investigacion en Ciencia Aplicada y Tecnologia Avanzada, Legaria 694, Col. Irrigacion, 11500 Mexico D. F. (Mexico); Azorin, J. [Universidad Autonoma Metropolitana, Unidad Iztapalapa, San Rafael Atlixco No. 186, Col. Vicentina, 09340 Mexico D. F. (Mexico); Azorin, J. C. [Universidad de Guanajuato, Division de Ciencias e Ingenierias-Campus Leon, Lomas del Bosque No. 103, Col. Lomas del Campestre, 37000 Leon, Guanajuato (Mexico); Licona, R.; Rivas, F.; Hernandez C, G. [Benemerita Universidad Autonoma de Puebla, Facultad de Ciencias Quimicas, 14 Sur y San Claudio, Ciudad Universitaria, Puebla de Zaragoza, Puebla (Mexico); Khaidukov, N. [Institute of General and Inorganic Chemistry, Lenin SK 11 Prospect 31, Moscow 117907 (Russian Federation)

    2011-02-15

    This paper presents results of studying the thermo-transferred thermoluminescence (TTTl) phenomenon in potassium-yttrium double fluoride doped with terbium (K{sub 2}YF{sub 5:}Tb) at different impurity concentrations (0.8%, 0.95% and 0.99%). Previously to study the TTTl phenomenon, structural characterization and chemical composition of the materials were determined. The structural studies were conducted using a scanning electron microscope; meanwhile, chemical composition was analyzed using energy dispersive X-ray spectroscopy. Thermoluminescence kinetics was studied irradiating the samples with {sup 137}Cs gamma rays as well as with {sup 90}Sr/{sup 90}Y beta rays, analyzing the glow curves by the deconvolution method for obtaining the kinetic parameters. (Author)

  7. Terbium Radionuclides for Theranostics Applications: A Focus On MEDICIS-PROMED

    Science.gov (United States)

    Cavaier, R. Formento; Haddad, F.; Sounalet, T.; Stora, T.; Zahi, I.

    A new facility, named CERN-MEDICIS, is under construction at CERN to produce radionuclides for medical applications. In parallel, the MEDICIS-PROMED, a Marie Sklodowska-Curie innovative training network of the Horizon 2020 European Commission's program, is being coordinated by CERN to train young scientists on the production and use of innovative radionuclides and develop a network of experts within Europe. One program within MEDICIS-PROMED is to determine the feasibility of producing innovative radioisotopes for theranostics using a commercial middle-sized high-current cyclotron and the mass separation technology developed at CERN-MEDICIS. This will allow the production of high specific activity radioisotopes not achievable with the common post-processing by chemical separation. Radioisotopes of scandium, copper, arsenic and terbium have been identified. Preliminary studies of activation yield and irradiation parameters optimization for the production of Tb-149 will be described.

  8. Dielectric and conducting behavior of gadolinium-terbium fumarate heptahydrate crystals

    Science.gov (United States)

    Shah, M. D.; Want, B.

    2015-07-01

    Gadolinium-terbium fumarate heptahydrate crystals were grown in silica gel by using single gel diffusion technique. The crystals were characterized by different physico-chemical techniques of characterization. Powder X-ray diffraction results showed that the grown material is purely crystalline in nature. Elemental analyses suggested the chemical formula of the compound to be Gd Tb (C4H2O4)3ṡ7H2O. Energy dispersive X-ray analysis confirmed the presence of Gd and Tb in the title compound. The dielectric and conductivity studies of the grown compound were carried as function of frequency of applied field and the temperature. The grown material showed a dielectric anomaly which was correlated with its thermal behavior. The ac conductivity of the material showed Jonscher's power law behavior: σ(ω)=σo+Aωs, with a temperature-dependent power exponent s(<1). The conductivity was found to be a function of temperature and frequency.

  9. Highly sensitive detection of dipicolinic acid with a water-dispersible terbium-metal organic framework.

    Science.gov (United States)

    Bhardwaj, Neha; Bhardwaj, Sanjeev; Mehta, Jyotsana; Kim, Ki-Hyun; Deep, Akash

    2016-12-15

    The sensitive detection of dipicolinic acid (DPA) is strongly associated with the sensing of bacterial organisms in food and many types of environmental samples. To date, the demand for a sensitive detection method for bacterial toxicity has increased remarkably. Herein, we investigated the DPA detection potential of a water-dispersible terbium-metal organic framework (Tb-MOF) based on the fluorescence quenching mechanism. The Tb-MOF showed a highly sensitive ability to detect DPA at a limit of detection of 0.04nM (linear range of detection: 1nM to 5µM) and also offered enhanced selectivity from other commonly associated organic molecules. The present study provides a basis for the application of Tb-MOF for direct, convenient, highly sensitive, and specific detection of DPA in the actual samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Ultralarge magneto-optic rotations and rotary dispersion in terbium gallium garnet single crystal.

    Science.gov (United States)

    Shaheen, Amrozia; Majeed, Hassaan; Anwar, Muhammad Sabieh

    2015-06-10

    We report systematically acquired data on the Verdet constant of terbium gallium garnet for wavelengths ranging from visible to near-infrared (405-830 nm) regime. Our experimental method of Stokes polarimetry is based on the Fourier decomposition of the received light intensity and allows unambiguous determination of both the Faraday rotation and the ellipticity of the emergent light. Temperature-dependent investigations in the range of 8-300 K extend earlier reports and verify the Verdet's constant direct dependence on the magnetization, whose first-order approximation is simply a manifestation of the Curie's law. Further, a least-squares fitting of the experimental data correlates well with theoretical predictions. At a wavelength of 405 nm and temperature of 8 K, the rotation is approximately 500°.

  11. Terbium fluorescence as a sensitive, inexpensive probe for UV-induced damage in nucleic acids

    Energy Technology Data Exchange (ETDEWEB)

    El-Yazbi, Amira F.; Loppnow, Glen R., E-mail: glen.loppnow@ualberta.ca

    2013-07-05

    Graphical abstract: -- Highlights: •Simple, inexpensive, mix-and-read assay for positive detection of DNA damage. •Recognition of undamaged DNA via hybridization to a hairpin probe. •Terbium(III) fluorescence reports the amount of damage by binding to ssDNA. •Tb/hairpin is a highly selective and sensitive fluorescent probe for DNA damage. -- Abstract: Much effort has been focused on developing methods for detecting damaged nucleic acids. However, almost all of the proposed methods consist of multi-step procedures, are limited, require expensive instruments, or suffer from a high level of interferences. In this paper, we present a novel simple, inexpensive, mix-and-read assay that is generally applicable to nucleic acid damage and uses the enhanced luminescence due to energy transfer from nucleic acids to terbium(III) (Tb{sup 3+}). Single-stranded oligonucleotides greatly enhance the Tb{sup 3+} emission, but duplex DNA does not. With the use of a DNA hairpin probe complementary to the oligonucleotide of interest, the Tb{sup 3+}/hairpin probe is applied to detect ultraviolet (UV)-induced DNA damage. The hairpin probe hybridizes only with the undamaged DNA. However, the damaged DNA remains single-stranded and enhances the intrinsic fluorescence of Tb{sup 3+}, producing a detectable signal directly proportional to the amount of DNA damage. This allows the Tb{sup 3+}/hairpin probe to be used for sensitive quantification of UV-induced DNA damage. The Tb{sup 3+}/hairpin probe showed superior selectivity to DNA damage compared to conventional molecular beacons probes (MBs) and its sensitivity is more than 2.5 times higher than MBs with a limit of detection of 4.36 ± 1.2 nM. In addition, this probe is easier to synthesize and more than eight times cheaper than MBs, which makes its use recommended for high-throughput, quantitative analysis of DNA damage.

  12. Fine- and hyperfine structure investigations of even configuration system of atomic terbium

    Science.gov (United States)

    Stefanska, D.; Elantkowska, M.; Ruczkowski, J.; Furmann, B.

    2017-03-01

    In this work a parametric study of the fine structure (fs) and the hyperfine structure (hfs) for the even-parity configurations of atomic terbium (Tb I) is presented, based in considerable part on the new experimental results. Measurements on 134 spectral lines were performed by laser induced fluorescence (LIF) in a hollow cathode discharge lamp; on this basis, the hyperfine structure constants A and B were determined for 52 even-parity levels belonging to the configurations 4f85d6s2, 4f85d26s or 4f96s6p; in all the cases those levels were involved in the transitions investigated as the lower levels. For 40 levels the hfs was examined for the first time, and for the remaining 12 levels the new measurements supplement our earlier results. As a by-product, also preliminary values of the hfs constants for 84 odd-parity levels were determined (the investigations of the odd-parity levels system in the terbium atom are still in progress). This huge amount of new experimental data, supplemented by our earlier published results, were considered for the fine and hyperfine structure analysis. A multi-configuration fit of 7 configurations was performed, taking into account second-order of perturbation theory, including the effects of closed shell-open shell excitations. Predicted values of the level energies, as well as of magnetic dipole and electric quadrupole hyperfine structure constants A and B, are quoted in cases when no experimental values are available. By combining our experimental data with our own semi-empirical procedure it was possible to identify correctly the lower and upper level of the line 544.1440 nm measured by Childs with the use of the atomic-beam laser-rf double-resonance technique (Childs, J Opt Soc Am B 9;1992:191-6).

  13. Determination of fluoxetine in pharmaceutical and biological samples based on the silver nanoparticle enhanced fluorescence of fluoxetine-terbium complex.

    Science.gov (United States)

    Lotfi, Ali; Manzoori, Jamshid L

    2016-11-01

    In this study, a simple and sensitive spectrofluorimetric method is presented for the determination of fluoxetine based on the enhancing effect of silver nanoparticles (AgNPs) on the terbium-fluoxetine fluorescence emission. The AgNPs were prepared by a simple reduction method and characterized by UV-Vis spectroscopy and transmission electron microscopy. It was indicated that these AgNPs have a remarkable amplifying effect on the terbium-sensitized fluorescence of fluoxetine. The effects of various parameters such as AgNP and Tb(3+) concentration and the pH of the media were investigated. Under obtained optimal conditions, the fluorescence intensity of the terbium-fluoxetine-AgNP system was enhanced linearly by increasing the concentration of fluoxetine in the range of 0.008 to 19 mg/L. The limit of detection (b + 3s) was 8.3 × 10(-4) mg/L. The interference effects of common species found in real samples were also studied. The method had good linearity, recovery, reproducibility and sensitivity, and was satisfactorily applied for the determination of fluoxetine in tablet formulations, human urine and plasma samples. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  14. Neutron Diffraction and Electrical Transport Studies on Magnetic Transition in Terbium at High Pressures and Low Temperatures

    Science.gov (United States)

    Thomas, Sarah; Montgomery, Jeffrey; Tsoi, Georgiy; Vohra, Yogesh; Weir, Samuel; Tulk, Christopher; Moreira Dos Santos, Antonio

    2013-06-01

    Neutron diffraction and electrical transport measurements have been carried out on the heavy rare earth metal terbium at high pressures and low temperatures in order to elucidate its transition from a helical antiferromagnetic to a ferromagnetic ordered phase as a function of pressure. The electrical resistance measurements using designer diamonds show a change in slope as the temperature is lowered through the ferromagnetic Curie temperature. The temperature of the ferromagnetic transition decreases at a rate of -16.7 K/GPa till 3.6 GPa, where terbium undergoes a structural transition from hexagonal close packed (hcp) to an α-Sm phase. Above this pressure, the electrical resistance measurements no longer exhibit a change in slope. In order to confirm the change in magnetic phase suggested by the electrical resistance measurements, neutron diffraction measurements were conducted at the SNAP beamline at the Oak Ridge National Laboratory. Measurements were made at pressures to 5.3 GPa and temperatures as low as 90 K. An abrupt increase in peak intensity in the neutron diffraction spectra signaled the onset of magnetic order below the Curie temperature. A magnetic phase diagram of rare earth metal terbium will be presented to 5.3 GPa and 90 K based on these studies.

  15. Effect of Ising-type Tb3+ ions on the low-temperature magnetism of La, Ca cobaltite.

    Science.gov (United States)

    Knížek, K; Jirák, Z; Hejtmánek, J; Veverka, M; Kaman, O; Maryško, M; Santavá, E; André, G

    2014-03-19

    Crystal and magnetic structures of the x = 0.2 member of the La0.8-xTbxCa0.2CoO3 perovskite series have been determined from powder neutron diffraction. Enhancement of the diffraction peaks due to ferromagnetic or cluster glass ordering is observed below TC = 55 K. The moments first evolve on Co sites, and ordering of Ising-type Tb(3+) moments is induced at lower temperatures by a molecular field due to Co ions. The final magnetic configuration is collinear Fx for the cobalt subsystem, while it is canted FxCy for terbium ions. The rare-earth moments align along local Ising axes within the ab-plane of the orthorhombic Pbnm structure. The behavior in external fields up to 70-90 kOe has been probed by magnetization and heat capacity measurements. The dilute terbium ions contribute to significant coercivity and remanence that both steeply increase with decreasing temperature. A remarkable manifestation of the Tb(3+) Ising character is the observation of a low-temperature region with an anomalously large linear term of heat capacity and its field dependence. Similar behaviors are detected also for other terbium dopings x = 0.1 and 0.3.

  16. Laser control and temperature switching of luminescence intensity in photostable transparent film based on terbium(III) β-diketonate complex

    Science.gov (United States)

    Lapaev, Dmitry V.; Nikiforov, Victor G.; Safiullin, Georgy M.; Lobkov, Vladimir S.; Salikhov, Kev M.; Knyazev, Andrey A.; Galyametdinov, Yury G.

    2014-11-01

    The study of the terbium(III) and gadolinium(III) β-diketonate complexes by photoluminescence spectroscopy reveals considerable changes of the photophysical properties of the complexes under the UV laser irradiation. The measurements show the enhancement of the luminescence intensities in the vitrified transparent film of the terbium(III) complex as well as the gadolinium(III) complex under the 337 nm laser irradiation at room temperature. The irradiated film of the terbium(III) complex restores the initial photophysical properties after heating close to the melting temperature (∼353 K) and cooling. We observe no change of the luminescent properties of the irradiated film for months. These features can be used for the design of new lanthanide-based photostable systems with laser control of the luminescence intensity.

  17. Development of functionalized terbium fluorescent nanoparticles for antibody labeling and time-resolved fluoroimmunoassay application.

    Science.gov (United States)

    Ye, Zhiqiang; Tan, Mingqian; Wang, Guilan; Yuan, Jingli

    2005-01-15

    Silica-based functionalized terbium fluorescent nanoparticles were prepared, characterized and developed as a fluorescence probe for antibody labeling and time-resolved fluoroimmunoassay. The nanoparticles were prepared in a water-in-oil (W/O) microemulsion containing a strongly fluorescent Tb(3+) chelate, N,N,N(1),N(1)-[2,6-bis(3'-aminomethyl-1'-pyrazolyl)phenylpyridine] tetrakis(acetate)-Tb(3+) (BPTA-Tb(3+)), Triton X-100, octanol, and cyclohexane by controlling copolymerization of tetraethyl orthosilicate (TEOS) and 3-[2-(2-aminoethylamino)ethylamino]propyl-trimethoxysilane (AEPS) with ammonia water. The characterizations by transmission electron microscopy and fluorometric methods show that the nanoparticles are spherical and uniform in size, 45 +/- 3nm in diameter, strongly fluorescent with fluorescence quantum yield of 10% and a long fluorescence lifetime of 2.0ms. The amino groups directly introduced to the nanoparticle's surface by using AEPS in the preparation made the surface modification and bioconjugation of the nanoparticles easier. The nanoparticle-labeled anti-human alpha-fetoprotein antibody was prepared and used for time-resolved fluoroimmunoassay of alpha-fetoprotein (AFP) in human serum samples. The assay response is linear from 0.10ngml(-1) to about 100ngml(-1) with the detection limit of 0.10ngml(-1). The coefficient variations (CVs) of the method are less than 9.0%, and the recoveries are in the range of 84-98% for human serum sample measurements.

  18. A Terbium Sensitized Luminescence Method for the Assay of Flubiprofen in Pharmaceutical Formulations

    Directory of Open Access Journals (Sweden)

    Salma M.Z. Al-Kindy

    2014-12-01

    Full Text Available A sensitive time-resolved luminescence method for the determination of flubiprofen (FLP in methanol and in aqueous solution is described. The method is based on the luminescence sensitization of terbium (Tb3+ by the formation of a ternary complex with FLP in the presence of 4,7 diphenyl 1,10 phenanthroline (DPP as co-ligand, and Tween-20 as surfactant. The signal for Tb-FLP-DPP was monitored at λex  = 285 nm and λem  = 552 nm. Optimum conditions for the formation of the complex in an aqueous system were TRIS buffer, pH 8.0, DPP (2.5Å~10−7  M, Tween-20 (0.30% and 4Å~10-5  mol L-1  of Tb3+  which allowed the determination of 20–1000 ng mL-1  of FLP with a limit of detection (LOD of 10 ng mL-1 . The relative standard deviations of the method ranged between 0.6 and 1.4% indicating excellent reproducibility of the method. The proposed method was successfully applied for the assays of FLP in pharmaceutical formulations and spiked tap water samples with average recoveries of 87% – 95%.

  19. Terbium-Doped VO2 Thin Films: Reduced Phase Transition Temperature and Largely Enhanced Luminous Transmittance.

    Science.gov (United States)

    Wang, Ning; Duchamp, Martial; Dunin-Borkowski, Rafal E; Liu, Shiyu; Zeng, XianTing; Cao, Xun; Long, Yi

    2016-01-26

    Vanadium dioxide (VO2) is a well-known thermochromic material with large IR modulating ability, promising for energy-saving smart windows. The main drawbacks of VO2 are its high phase transition temperature (τ(c) = 68°C), low luminous transmission (T(lum)), and weak solar modulating ability (ΔT(sol)). In this paper, the terbium cation (Tb(3+)) doping was first reported to reduce τ(c) and increase T(lum) of VO2 thin films. Compared with pristine VO2, 2 at. % doping level gives both enhanced T(lum) and ΔT(sol) from 45.8% to 54.0% and 7.7% to 8.3%, respectively. The T(lum) increases with continuous Tb(3+) doping and reaches 79.4% at 6 at. % doping level, representing ∼73.4% relative increment compared with pure VO2. This has surpassed the best reported doped VO2 thin films. The enhanced thermochromic properties is meaningful for smart window applications of VO2 materials.

  20. Luminescent europium and terbium complexes of dipyridoquinoxaline and dipyridophenazine ligands as photosensitizing antennae: structures and biological perspectives.

    Science.gov (United States)

    Dasari, Srikanth; Patra, Ashis K

    2015-12-14

    The europium(III) and terbium(III) complexes, namely [Eu(dpq)(DMF)2(NO3)3] (1), [Eu(dppz)2(NO3)3] (2), [Tb(dpq)(DMF)2Cl3] (3), and [Tb(dppz)(DMF)2Cl3] (4), where dipyrido[3,2-d:2',3'-f]quinoxaline (dpq in 1 and 3), dipyrido[3,2-a:2',3'-c]phenazine (dppz in 2 and 4) and N,N'-dimethylformamide (DMF) have been isolated, characterized from their physicochemical data, luminescence studies and their interaction with DNA, serum albumin protein and photo-induced DNA cleavage activity are studied. The X-ray crystal structures of complexes 1-4 show discrete mononuclear Ln(3+)-based structures. The Eu(3+) in [Eu(dpq)(DMF)2(NO3)3] (1) and [Eu(dppz)2(NO3)3] (2) as [Eu(dppz)2(NO3)3]·dppz (2a) adopts a ten-coordinated bicapped dodecahedron structure with a bidentate N,N-donor dpq ligand, two DMF and three NO3(-) anions in 1 and two bidentate N,N-donor dppz ligands and three NO3(-) anions in 2. Complexes 3 and 4 show a seven-coordinated mono-capped octahedron structure where Tb(3+) contains bidentate dpq/dppz ligands, two DMF and three Cl(-) anions. The complexes are highly luminescent in nature indicating efficient photo-excited energy transfer from the dpq/dppz antenna to Ln(3+) to generate long-lived emissive excited states for characteristic f → f transitions. The time-resolved luminescence spectra of complexes 1-4 show typical narrow emission bands attributed to the (5)D0 → (7)F(J) and (5)D4 → (7)F(J) f-f transitions of Eu(3+) and Tb(3+) ions respectively. The number of inner-sphere water molecules (q) was determined from luminescence lifetime measurements in H2O and D2O confirming ligand-exchange reactions with water in solution. The complexes display significant binding propensity to the CT-DNA giving binding constant values in the range of 1.0 × 10(4)-6.1 × 10(4) M(-1) in the order 2, 4 (dppz) > 1, 3 (dpq). DNA binding data suggest DNA groove binding with the partial intercalation nature of the complexes. All the complexes also show binding propensity (K(BSA)

  1. Construction of the energy matrix for complex atoms. Part VIII: Hyperfine structure HPC calculations for terbium atom

    Science.gov (United States)

    Elantkowska, Magdalena; Ruczkowski, Jarosław; Sikorski, Andrzej; Dembczyński, Jerzy

    2017-11-01

    A parametric analysis of the hyperfine structure (hfs) for the even parity configurations of atomic terbium (Tb I) is presented in this work. We introduce the complete set of 4fN-core states in our high-performance computing (HPC) calculations. For calculations of the huge hyperfine structure matrix, requiring approximately 5000 hours when run on a single CPU, we propose the methods utilizing a personal computer cluster or, alternatively a cluster of Microsoft Azure virtual machines (VM). These methods give a factor 12 performance boost, enabling the calculations to complete in an acceptable time.

  2. Factors Affecting the Efficiency of Excited-States Interactions of Complexes between Some Visible Light-Emitting Lanthanide Ions and Cyclophanes Containing Spirobiindanol Phosphonates

    Directory of Open Access Journals (Sweden)

    M. S. Attia

    2007-01-01

    Full Text Available The efficiency of excited-states interactions between lanthanide ions Tb3+ and Eu3+ and some new cyclophanes (I, II, and III has been studied in different media. High luminescence quantum yield values for terbium and europium complexes in DMSO and PMMA were obtained. The photophysical properties of the green and red emissive Tb3+ and Eu3+ complexes have been elucidated, respectively.

  3. Spectrofluorimetric determination of human serum albumin using terbium-danofloxacin probe.

    Science.gov (United States)

    Ramezani, Amir M; Manzoori, Jamshid L; Amjadi, Mohammad; Jouyban, Abolghasem

    2012-01-01

    A spectrofluorimetric method is proposed for the determination of human serum albumin (HSA) and bovine serum albumin (BSA) using terbium-danofloxacin (Tb(3+)-Dano) as a fluorescent probe. These proteins remarkably enhance the fluorescence intensity of the Tb(3+)-Dano complex at 545 nm, and the enhanced fluorescence intensity of Tb(3+)-Dano is proportional to the concentration of proteins (HSA and BSA). Optimum conditions for the determination of HSA were investigated and found that the maximum response was observed at: pH = 7.8, [Tb(3+)] = 8.5 × 10(-5) mol L(-1), [Dano] = 1.5 × 10(-4) mol L(-1). The calibration graphs for standard solutions of BSA, HSA, and plasma samples of HSA were linear in the range of 0.2 × 10(-6) - 1.3 × 10(-6) mol L(-1), 0.2 × 10(-6) - 1.4 × 10(-6) mol L(-1), and 0.2 × 10(-6) - 1 × 10(-6) mol L(-1), respectively. The detection limits (S/N = 3) for BSA, HSA, and plasma sample of HSA were 8.7 × 10(-8) mol L(-1), 6.2 × 10(-8) mol L(-1), and 8.1 × 10(-8) mol L(-1), respectively. The applicability of the method was checked using a number of real biological plasma samples and was compared with the UV spectrometric reference method. The results was showed that the method could be regarded as a simple, practical, and sensitive alternative method for determination of albumin in biological samples.

  4. Spectrofluorimetric Determination of Human Serum Albumin Using Terbium-Danofloxacin Probe

    Directory of Open Access Journals (Sweden)

    Amir M. Ramezani

    2012-01-01

    Full Text Available A spectrofluorimetric method is proposed for the determination of human serum albumin (HSA and bovine serum albumin (BSA using terbium-danofloxacin (Tb3+-Dano as a fluorescent probe. These proteins remarkably enhance the fluorescence intensity of the Tb3+-Dano complex at 545 nm, and the enhanced fluorescence intensity of Tb3+-Dano is proportional to the concentration of proteins (HSA and BSA. Optimum conditions for the determination of HSA were investigated and found that the maximum response was observed at: pH=7.8, [Tb3+] =8.5×10−5 mol L−1, [Dano] =1.5×10−4 mol L−1. The calibration graphs for standard solutions of BSA, HSA, and plasma samples of HSA were linear in the range of 0.2×10−6−1.3×10−6 mol L−1, 0.2×10−6−1.4×10−6 mol L−1, and 0.2×10−6−1×10−6 mol L−1, respectively. The detection limits (S/N = 3 for BSA, HSA, and plasma sample of HSA were 8.7×10−8 mol L−1, 6.2×10−8 mol L−1, and 8.1×10−8 mol L−1, respectively. The applicability of the method was checked using a number of real biological plasma samples and was compared with the UV spectrometric reference method. The results was showed that the method could be regarded as a simple, practical, and sensitive alternative method for determination of albumin in biological samples.

  5. Determination of flavonoids in pharmaceutical preparations using Terbium sensitized fluorescence method

    Directory of Open Access Journals (Sweden)

    M Shaghaghi

    2009-12-01

    Full Text Available "nBackground and the Purpose of the Study: The aim of this study was development and validation of a simple, rapid and sensitive spectrofluorimetric method for determination of total flavonoids in two topical formulations of Calendula officinalis, Ziziphus Spina-christi and an oral drop of Hypiran perforatum L. The proposed method is based on the formation of terbium (Tb3+ "n-flavonoids (quercetin as a reference standard complex at pH 7.0, which has fluorescence intensely with maximum emission at 545 nm when excited at 310 nm. "nMethod "n: For ointments masses of topical formulations were weighed and added to ethanol-aqueous buffer (pH 10.0 and the resulting mixtures were shaken and then two phases were separated by centrifugation. Aqueous phases were filtered and then diluted with water. For Hypiran drops an appropriate portion was diluted with ethanol and then aliquots of sample or standard solutions were determined according to the experimental procedure. "nResults "n: Under the optimum conditions, total concentrations of flavonoids (as quercetin equivalent in three tested formulations were found to be 0.204 mg/g (for Dermatin cream, 0.476 mg/g (for Calendula ointment and 13.50 μg/ml (for Hypiran drops. Analytical recoveries from samples spiked with different amounts of quercetin were 96.1-104.0 % with RSD % of less than 3.5. Conclusion : The proposed method which requires a simple dissolution step without any matrix interferences provided high sensitivity and selectivity and was easily applied to determine total flavonoids in real samples of three investigated formulations with excellent reproducibility.

  6. Synthesis, crystal structure and photophysical properties of europium(III) and terbium(III) complexes with pyridine-2,6-dicarboxamide

    NARCIS (Netherlands)

    Tanase, S.; Gallego, P.M.; Gelder, R. de; Fu, W.T.

    2007-01-01

    The reactions of pyridine-2,6-dicarboxamide with europium(III) and terbium(III) triflates led to the formation of mononuclear complexes of formula [Ln(pcam)(3)](CF3SO3)(3) (Ln = Eu 1, Tb 2; pcam stands for pyridine-2,6-dicarboxamide). From single-crystal X-ray diffraction analysis, the complexes

  7. Zinc sulfide and terbium-doped zinc sulfide films grown by traveling wave reactor atomic layer epitaxy

    CERN Document Server

    Yun, S J; Nam, K S

    1998-01-01

    Zinc sulfide (ZnS) and terbium-doped ZnS (ZnS:Tb) thin films were grown by traveling wave reactor atomic layer epitaxy (ALE). In the present work, ZnCl sub 2 , H sub 2 S, and tris (2,2,6,6-tetramethyl-3,5-heptandionato) terbium (Tb(tmhd) sub 3) were used as the precursors. The dependence of crystallinity and Cl content of ZnS films was investigated on the growth temperature. ZnS and ZnS:Tb films grown at temperatures ranging from 400 to 500 .deg. C showed a hexagonal-2H crystalline structure. The crystallinity of ZnS film was greatly enhanced as the temperature increased. At growth temperatures higher than 450.deg.C, the films showed preferred orientation with mainly (002) diffraction peak. The Cl content decreased from approximately 9 to 1 at.% with the increase in growth temperature from 400 to 500 .deg. C. The segregation of Cl near the surface region and the incorporation of O from Tb(tmhd) sub 3 during ALE process were also observed using Auger electron spectroscopy. The ALE-grown ZnS and ZnS:Tb films re...

  8. Commercializing potassium terbium fluoride, KTF (KTb3F10) faraday crystals for high laser power optical isolator applications

    Science.gov (United States)

    Schlichting, Wolfgang; Stevens, Kevin; Foundos, Greg; Payne, Alexis

    2017-10-01

    Many scientific lasers and increasingly industrial laser systems operate in power regime, require high-performance optical isolators to prevent disruptive light feedback into the laser cavity. The optically active Faraday material is the key optical element inside the isolator. SYNOPTICS has been supplying the laser market with Terbium Gallium Garnet (TGG - Tb3Ga5O12) for many years. It is the most commonly used material for the 650-1100nm range and the key advantages for TGG include its cubic crystal structure for alignment free processing, little to no intrinsic birefringence, and ease of manufacture. However, for high-power laser applications TGG is limited by its absorption at 1064nm and its thermo-optic coefficient, dn/dT. Specifically, thermal lensing and depolarization effects become a limiting factor at high laser powers. While TGG absorption has improved significantly over the past few years, there is an intrinsic limit. Now, SYNOPTICS is commercializing the enhanced new crystal Potassium Terbium Fluoride KTF (KTb3F10) that exhibits much smaller nonlinear refractive index and thermo-optic coefficients, and still exhibits a Verdet constant near that of TGG. This cubic crystal has relatively low absorption and thermo-optic coefficients. It is now fully characterized and available for select production orders. At OPTIFAB in October 2017 we present recent results comparing the performance of KTF to TGG in optical isolators and show SYNOPTICS advances in large volume crystal growth and the production ramp up.

  9. Improving green emission of Tb3+ions in BaO-B2O3-P2O5glasses by means of Al3+ions.

    Science.gov (United States)

    Kalpana, T; Gandhi, Y; Sudarsan, V; Piasecki, M; Ravi Kumar, V; Veeraiah, N

    2016-11-01

    BaO-B 2 O 3 -P 2 O 5 glasses doped with a fixed concentration of Tb 3 + ions and varying concentrations of Al 2 O 3 were synthesized, and the influence of the Al 3 + ion concentration on the luminescence efficiency of the green emission of Tb 3 + ions was investigated. The optical absorption, excitation, luminescence spectra and fluorescence decay curves of these glasses were recorded at ambient temperature. The emission spectra of terbium ions when excited at 393 nm exhibited two main groups of bands, corresponding to 5 D 3  →  7 F j (blue region) and 5 D 4  → 7F j (green region). From these spectra, the radiative parameters, viz., spontaneous emission probability A, total emission probability A T , radiative lifetime τ and fluorescent branching ratio β, of different transitions originating from the 5 D 4 level of Tb 3 + ions were evaluated based on the Judd-Ofelt theory. A clear increase in the quantum efficiency and luminescence of the green emission of Tb 3 + ions corresponding to 5 D 4  →  7 F 5 transition is observed with increases in the concentration of Al 2 O 3 up to 3.0 mol%. The improvement in emission is attributed to the de-clustering of terbium ions by Al 3 + ions and also to the possible admixing of wave functions of opposite parities. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  10. Complete Stokes polarimetry of magneto-optical Faraday effect in a terbium gallium garnet crystal at cryogenic temperatures.

    Science.gov (United States)

    Majeed, Hassaan; Shaheen, Amrozia; Anwar, Muhammad Sabieh

    2013-10-21

    We report the complete determination of the polarization changes caused in linearly polarized incident light due to propagation in a magneto-optically active terbium gallium garnet (TGG) single crystal, at temperatures ranging from 6.3 to 300 K. A 28-fold increase in the Verdet constant of the TGG crystal is seen as its temperature decreases to 6.3 K. In contrast with polarimetry of light emerging from a Faraday material at room temperature, polarimetry at cryogenic temperatures cannot be carried out using the conventional fixed polarizer-analyzer technique because the assumption that ellipticity is negligible becomes increasingly invalid as temperature is lowered. It is shown that complete determination of light polarization in such a case requires the determination of its Stokes parameters, otherwise inaccurate measurements will result with negative implications for practical devices.

  11. Development of Optical Isolators for Visible Light Using Terbium Aluminum Garnet (Tb3Al5O12) Single Crystals

    Science.gov (United States)

    Geho, Mikio; Takagi, Takashi; Chiku, Shinichiro; Fujii, Takashi

    2005-07-01

    We have recently reported the successful growth of incongruently melting terbium aluminum garnet (Tb3Al5O12; TAG) single crystals by the hybrid laser FZ (floating zone) method. Optical property evaluations confirmed a high transmittance and a larger Verdet constant than conventional Tb3Ga5O12 (TGG) crystals and/or Faraday glasses. In this study, we attempted to design, fabricate, and evaluate optical isolators in visible light through near-infrared (NIR) regions using TAG crystals. A finite element method (FEM) simulation of possible models led us to the preferable one based on a radially magnetized magnet. To realize this, we employed a pseudo-radially magnetized magnet. The target wavelengths of the prototype device were 408, 808, and 1064 nm. The typical extinction ratio was more than 30 dB and the insertion loss was less than 0.3 dB for AR-coated devices.

  12. A hydrometallurgical process for the recovery of terbium from fluorescent lamps: Experimental design, optimization of acid leaching process and process analysis.

    Science.gov (United States)

    Innocenzi, Valentina; Ippolito, Nicolò Maria; De Michelis, Ida; Medici, Franco; Vegliò, Francesco

    2016-12-15

    Terbium and rare earths recovery from fluorescent powders of exhausted lamps by acid leaching with hydrochloric acid was the objective of this study. In order to investigate the factors affecting leaching a series of experiments was performed in according to a full factorial plan with four variables and two levels (4 2 ). The factors studied were temperature, concentration of acid, pulp density and leaching time. Experimental conditions of terbium dissolution were optimized by statistical analysis. The results showed that temperature and pulp density were significant with a positive and negative effect, respectively. The empirical mathematical model deducted by experimental data demonstrated that terbium content was completely dissolved under the following conditions: 90 °C, 2 M hydrochloric acid and 5% of pulp density; while when the pulp density was 15% an extraction of 83% could be obtained at 90 °C and 5 M hydrochloric acid. Finally a flow sheet for the recovery of rare earth elements was proposed. The process was tested and simulated by commercial software for the chemical processes. The mass balance of the process was calculated: from 1 ton of initial powder it was possible to obtain around 160 kg of a concentrate of rare earths having a purity of 99%. The main rare earths elements in the final product was yttrium oxide (86.43%) following by cerium oxide (4.11%), lanthanum oxide (3.18%), europium oxide (3.08%) and terbium oxide (2.20%). The estimated total recovery of the rare earths elements was around 70% for yttrium and europium and 80% for the other rare earths. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Micro-meter size organogelator with tri-color luminescence (blue, green and red) activated by Dy3+, Tb3+ and Eu3+ ions.

    Science.gov (United States)

    Wang, QianMing

    2009-09-01

    The preparation of a novel type of low-molecular-weight amphiphilic organogelator bearing three long 14-alkyl chains and hydrophilic oligo(oxyethylene) groups was described. Ultra-violet absorption and fluorescence spectra give evidence of the energy transfer between organic ligands to lanthanide ions. Characteristic green, blue and red luminescence of the organogels were obtained and interesting emission properties of terbium, dysprosium and europium ions were unexpectedly observed at the first time during the order-disorder phase transition point (29 degrees C).

  14. A europium- and terbium-coated magnetic nanocomposite as sorbent in dispersive solid phase extraction coupled with ultra-high performance liquid chromatography for antibiotic determination in meat samples.

    Science.gov (United States)

    Castillo-García, M L; Aguilar-Caballos, M P; Gómez-Hens, A

    2015-12-18

    A new magnetic dispersive solid-phase extraction approach based on Eu- and Tb-coated magnetic nanocomposites, combined with ultra-high performance liquid chromatography with fluorometric detection, is reported for the extraction and simultaneous determination of veterinary antibiotics. The method is aimed at monitoring of potential residues of three tetracyclines, namely oxytetracycline, tetracycline, chlortetracycline and three acidic quinolones, such as oxolinic acid, nalidixic acid and flumequine, chosen as model analytes, in animal muscle samples. The nanocomposites were obtained by synthesizing magnetic nanoparticles by a co-precipitation method and their coating with terbium and europium ions. The limits of detection obtained using standard solutions were: 1.0, 1.5, 3.8, 0.25, 0.7 and 1.2ngmL(-1), which corresponds to 3.3, 5.0, 12.7, 0.8, 2.3 and 4.0μgkg(-1) for oxytetracycline, tetracycline, chlortetracycline, oxolinic acid, nalidixic acid and flumequine, respectively, in meat samples. The precision values, obtained in the presence of the sample matrix, were in the ranges 0.12-2.0% and 2.6-15.4% for retention times and areas, respectively. The selectivity of the method was checked by assaying different veterinary drugs, finding that most of them did not interfere at the same concentration levels as that of analytes. A recovery study was performed in the presence of chicken and pork muscle samples, which provided values in the range of 61.5-102.6%. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. ion with phenolate ions

    Indian Academy of Sciences (India)

    Administrator

    Photoinduced electron transfer (PET) reaction of homoleptic tris-chelated polypyridine ruthenium(II) complexes with phenolate ions is sensitive to the structure of the ligand of the Ru(II) complex as well as of the phenolate ions 1. In recent years 2 the photophysical and photochemical properties of Ru(II) complexes based on ...

  16. Fluorometric determination of proteins using the terbium (III)-2-thenoyltrifluoroacetone-sodium dodecyl benzene sulfonate-protein system

    Energy Technology Data Exchange (ETDEWEB)

    Jia Zhen [Key Laboratory of Colloid and Interface Chemistry of Education Ministry, School of Chemistry and Chemical Engineering, Shandong University, Jinan 250100 (China); Department of Chemistry, Dezhou University, Dezhou 253023 (China); Yang Jinghe [Key Laboratory of Colloid and Interface Chemistry of Education Ministry, School of Chemistry and Chemical Engineering, Shandong University, Jinan 250100 (China)]. E-mail: yjh@sdu.edu.cn; Wu Xia [Key Laboratory of Colloid and Interface Chemistry of Education Ministry, School of Chemistry and Chemical Engineering, Shandong University, Jinan 250100 (China); Wang Fei [Key Laboratory of Colloid and Interface Chemistry of Education Ministry, School of Chemistry and Chemical Engineering, Shandong University, Jinan 250100 (China); Guo Changying [Key Laboratory of Colloid and Interface Chemistry of Education Ministry, School of Chemistry and Chemical Engineering, Shandong University, Jinan 250100 (China); Liu Shufang [Key Laboratory of Colloid and Interface Chemistry of Education Ministry, School of Chemistry and Chemical Engineering, Shandong University, Jinan 250100 (China)

    2006-12-15

    It is found that in hexamethylene tetramine (HMTA)-HCl buffer of pH=8.00, proteins can enhance the fluorescence of terbium (III) (Tb{sup 3+})-2-thenoyltrifluoroacetone (TTA)-sodium dodecyl benzene sulfonate (SDBS) system. Based on this, a sensitive method for the determination of proteins is proposed. The experiments indicate that under the optimum conditions, the enhanced fluorescence intensity is in proportion to the concentration of proteins in the range of 4.0x10{sup -9}-7.5x10{sup -6}g/mL for bovine serum albumin (BSA), 5.0x10{sup -9}-1.5x10{sup -5}g/mL for human serum albumin (HSA), 1.0x10{sup -8}-7.5x10{sup -6}g/mL for egg albumin (EA). Their detection limits (S/N=3) are 0.5, 0.8 and 2.0ng/mL, respectively. The interaction mechanism is also studied.

  17. Terbium to Quantum Dot FRET Bioconjugates for Clinical Diagnostics: Influence of Human Plasma on Optical and Assembly Properties

    Directory of Open Access Journals (Sweden)

    Niko Hildebrandt

    2011-10-01

    Full Text Available Förster resonance energy transfer (FRET from luminescent terbium complexes (LTC as donors to semiconductor quantum dots (QDs as acceptors allows extraordinary large FRET efficiencies due to the long Förster distances afforded. Moreover, time-gated detection permits an efficient suppression of autofluorescent background leading to sub-picomolar detection limits even within multiplexed detection formats. These characteristics make FRET-systems with LTC and QDs excellent candidates for clinical diagnostics. So far, such proofs of principle for highly sensitive multiplexed biosensing have only been performed under optimized buffer conditions and interactions between real-life clinical media such as human serum or plasma and LTC-QD-FRET-systems have not yet been taken into account. Here we present an extensive spectroscopic analysis of absorption, excitation and emission spectra along with the luminescence decay times of both the single components as well as the assembled FRET-systems in TRIS-buffer, TRIS-buffer with 2% bovine serum albumin, and fresh human plasma. Moreover, we evaluated homogeneous LTC-QD FRET assays in QD conjugates assembled with either the well-known, specific biotin-streptavidin biological interaction or, alternatively, the metal-affinity coordination of histidine to zinc. In the case of conjugates assembled with biotin-streptavidin no significant interference with the optical and binding properties occurs whereas the histidine-zinc system appears to be affected by human plasma.

  18. Optical properties and electrical transport of thin films of terbium(III bis(phthalocyanine on cobalt

    Directory of Open Access Journals (Sweden)

    Peter Robaschik

    2014-11-01

    Full Text Available The optical and electrical properties of terbium(III bis(phthalocyanine (TbPc2 films on cobalt substrates were studied using variable angle spectroscopic ellipsometry (VASE and current sensing atomic force microscopy (cs-AFM. Thin films of TbPc2 with a thickness between 18 nm and 87 nm were prepared by organic molecular beam deposition onto a cobalt layer grown by electron beam evaporation. The molecular orientation of the molecules on the metallic film was estimated from the analysis of the spectroscopic ellipsometry data. A detailed analysis of the AFM topography shows that the TbPc2 films consist of islands which increase in size with the thickness of the organic film. Furthermore, the cs-AFM technique allows local variations of the organic film topography to be correlated with electrical transport properties. Local current mapping as well as local I–V spectroscopy shows that despite the granular structure of the films, the electrical transport is uniform through the organic films on the microscale. The AFM-based electrical measurements allow the local charge carrier mobility of the TbPc2 thin films to be quantified with nanoscale resolution.

  19. Micelle enhanced and terbium sensitized spectrofluorimetric determination of danofloxacin in milk using molecularly imprinted solid phase extraction

    Science.gov (United States)

    Kaur, Kuldeep; Saini, Shivender Singh; Malik, Ashok Kumar; Singh, Baldev

    2012-10-01

    An efficient molecularly imprinted solid phase extraction (MISPE)-spectrofluorimetric method was developed to sensitively determine danofloxacin (DAN) in milk samples. Solid phase extraction procedure using MISPE cartridges was first performed on milk samples and then spectrofluorimetric determination was done at 546 nm using an excitation wavelength of 285 nm in presence of terbium and sodium dodecyl benzene sulfonate (SDBS). It was found that SDBS significantly enhanced the fluorescence intensity of the DAN-Tb3+ complex. Various factors affecting the fluorescence intensity of DAN-Tb3+-SDBS system were studied and conditions were optimized. The enhanced fluorescence intensity of the system (ΔF) showed a good linear relationship with the concentration of DAN over the range of 8.4 × 10-9-3.4 × 10-7 mol L-1 with a correlation coefficient of 0.9996. The detection limit was determined as 2.0 × 10-9 mol L-1 and the limit of quantification was determined as 6.5 × 10-9 mol L-1. The MISPE-spectrofluorimetric procedure was successfully applied to the determination of DAN in milk samples. The method is simple, rapid, sensitive and allows interference free determination of DAN in complex fluorescent matrices like milk. The method can be used to determine whether the DAN residues in milk exceed MRLs or not.

  20. Spin waves in terbium. III. Magnetic anisotropy at zero wave vector

    DEFF Research Database (Denmark)

    Houmann, Jens Christian Gylden; Jensen, J.; Touborg, P.

    1975-01-01

    The energy gap at zero wave vector in the spin-wave dispersion relation of ferromagnetic. Tb has been studied by inelastic neutron scattering. The energy was measured as a function of temperature and applied magnetic field, and the dynamic anisotropy parameters were deduced from the results....... The axial anisotropy is found to depend sensitively on the orientation of the magnetic moments in the basal plane. This behavior is shown to be a convincing indication of considerable two-ion contributions to the magnetic anisotropy at zero wave vector. With the exception of the sixfold basal...... the effects of zero-point deviations from the fully aligned ground state, and we tentatively propose polarization-dependent two-ion couplings as their origin....

  1. Terbium-doped gadolinium oxysulfide (Gd2O2S:Tb) scintillation-based polymer optical fibre sensor for real time monitoring of radiation dose in oncology

    Science.gov (United States)

    Lewis, E.; O'Keeffe, S.; Grattan, M.; Hounsell, A.; McCarthy, D.; Woulfe, P.; Cronin, J.; Mihai, L.; Sporea, D.; Santhanam, A.; Agazaryan, N.

    2014-05-01

    A PMMA based plastic optical fibre sensor for use in real time radiotherapy dosimetry is presented. The optical fibre tip is coated with a scintillation material, terbium-doped gadolinium oxysulfide (Gd2O2S:Tb), which fluoresces when exposed to ionising radiation (X-Ray). The emitted visible light signal penetrates the sensor optical fibre and propagates along the transmitting fibre at the end of which it is remotely monitored using a fluorescence spectrometer. The results demonstrate good repeatability, with a maximum percentage error of 0.5% and the response is independent of dose rate.

  2. Charge-transfer-based terbium MOF nanoparticles as fluorescent pH sensor for extreme acidity.

    Science.gov (United States)

    Qi, Zewan; Chen, Yang

    2017-01-15

    Newly emerged metal organic frameworks (MOFs) have aroused the great interest in designing functional materials by means of its flexible structure and component. In this study, we used lanthanide Tb 3+ ions and small molecular ligands to design and assemble a kind of pH-sensitive MOF nanoparticle based on intramolecular-charge-transfer effect. This kind of made-to-order MOF nanoparticle for H + is highly specific and sensitive and could be used to fluorescently indicate pH value of strong acidic solution via preset mechanism through luminescence of Tb 3+ . The long luminescence lifetime of Tb 3+ allows eliminating concomitant non-specific fluorescence by time-revised fluorescence techniques, processing an advantage in sensing H + in biological media with strong autofluorescence. Our method showed a great potential of MOF structures in designing and constructing sensitive sensing materials for specific analytes directly via the assembly of functional ions/ligands. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Photoluminescence studies of a Terbium(III) complex as a fluorescent probe for DNA detection

    Energy Technology Data Exchange (ETDEWEB)

    Khorasani-Motlagh, Mozhgan, E-mail: mkhorasani@chem.usb.ac.ir; Noroozifar, Meissam; Niroomand, Sona; Moodi, Asieh

    2013-11-15

    The photoluminescence properties of a Tb(III) complex of the form [Tb(phen){sub 2}Cl{sub 3}·OH{sub 2}] (phen=1,10-phenanthroline) in different solvents are presented. It shows the characteristic luminescence of the corresponding Ln{sup 3+} ion in the visible region. The emission intensity of this complex in coordinating solvent is higher than non-coordinating one. The suggested mechanism for the energy transfer between the ligand and Tb{sup 3+} ion is the intramolecular energy transfer mechanism. The interactions of the Tb(III) complex with fish salmon DNA are studied by fluorescence spectroscopy, circular dichroism study and viscosity measurements. The results of fluorescence titration reveal that DNA strongly quenches the intrinsic fluorescence of the complex through a static quenching procedure. The binding constant (K{sub b}) of the above metal complex at 25 °C is determined by the fluorescence titration method and it is found to be (8.06±0.01)×10{sup 3} M{sup −1}. The thermodynamic parameters (ΔH{sup 0}>0, ΔS{sup 0}>0 and ΔG{sup 0}<0) indicate that the hydrophobic interactions play a major role in DNA–Tb complex association. The results support the claim that the title complex bonds to FS-DNA by a groove mode. -- Highlights: • Photoluminescence of [Tb(phen){sub 2}Cl{sub 3}·OH{sub 2}] in different solvents are studied. • Tb(III) complex shows good binding affinity to FS DNA with K{sub b}=(8.06±0.01)×10{sup 3} M{sup −1}. • Viscosity of DNA almost unchanged by increasing amount of Tb complex. • CD spectrum of DNA has a little change with increasing amount of Tb complex. • Thermodynamic parameters indicate that the binding reaction is entropically driven.

  4. Compact all-fiber optical Faraday components using 65-wt%-terbium-doped fiber with a record Verdet constant of -32 rad/(Tm).

    Science.gov (United States)

    Sun, L; Jiang, S; Marciante, J R

    2010-06-07

    A compact all-fiber Faraday isolator and a Faraday mirror are demonstrated. At the core of each of these components is an all-fiber Faraday rotator made of a 4-cm-long, 65-wt%-terbium-doped silicate fiber. The effective Verdet constant of the terbium-doped fiber is measured to be -32 rad/(Tm), which is 27 x larger than that of silica fiber. This effective Verdet constant is the largest value measured to date in any fiber and is 83% of the Verdet constant of commercially available crystal used in bulk optics-based isolators. Combining the all-fiber Faraday rotator with fiber polarizers results in a fully fusion spliced all-fiber isolator whose isolation is measured to be 19 dB. Combining the all-fiber Faraday rotator with a fiber Bragg grating results in an all-fiber Faraday mirror that rotates the polarization state of the reflected light by 88 +/- 4 degrees .

  5. Picomolar Traces of Americium(III) Introduce Drastic Changes in the Structural Chemistry of Terbium(III): A Break in the "Gadolinium Break".

    Science.gov (United States)

    Welch, Jan M; Müller, Danny; Knoll, Christian; Wilkovitsch, Martin; Giester, Gerald; Ofner, Johannes; Lendl, Bernhard; Weinberger, Peter; Steinhauser, Georg

    2017-10-16

    The crystallization of terbium 5,5'-azobis[1H-tetrazol-1-ide] (ZT) in the presence of trace amounts (ca. 50 Bq, ca. 1.6 pmol) of americium results in 1) the accumulation of the americium tracer in the crystalline solid and 2) a material that adopts a different crystal structure to that formed in the absence of americium. Americium-doped [Tb(Am)(H 2 O) 7 ZT] 2 ZT⋅10 H 2 O is isostructural to light lanthanide (Ce-Gd) 5,5'-azobis[1H-tetrazol-1-ide] compounds, rather than to the heavy lanthanide (Tb-Lu) 5,5'-azobis[1H-tetrazol-1-ide] (e.g., [Tb(H 2 O) 8 ] 2 ZT 3 ⋅6 H 2 O) derivatives. Traces of Am seem to force the Tb compound into a structure normally preferred by the lighter lanthanides, despite a 10 8 -fold Tb excess. The americium-doped material was studied by single-crystal X-ray diffraction, vibrational spectroscopy, radiochemical neutron activation analysis, and scanning electron microcopy. In addition, the inclusion properties of terbium 5,5'-azobis[1H-tetrazol-1-ide] towards americium were quantified, and a model for the crystallization process is proposed. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Assessment of terbium (III) as a luminescent probe for the detection of tuberculosis biomarkers

    Energy Technology Data Exchange (ETDEWEB)

    Bamogo, W. [CNRS, IRAMIS, UMR 3685 NIMBE/LEDNA, F-91191 Gif-sur-Yvette (France); Mugherli, L. [CEA, IRAMIS, UMR 3685 NIMBE/LEDNA, F-91191 Gif-sur-Yvette (France); Banyasz, A. [CNRS, IRAMIS, LIDyL/Laboratoire Francis Perrin, URA 2453, F-91191 Gif-sur-Yvette (France); Novelli-Rousseau, A.; Mallard, F. [BioMérieux SA, F-38000 Grenoble (France); Tran-Thi, T.-H., E-mail: thu-hoa.tran-thi@cea.fr [CNRS, IRAMIS, UMR 3685 NIMBE/LEDNA, F-91191 Gif-sur-Yvette (France)

    2015-10-08

    A detection method for nicotinic acid, a specific metabolite marker of Mycobacterium tuberculosis present in cultures and patients' breath, is studied in complex solutions containing other metabolites and in biological media such as urine, saliva and breath condensate. The method is based on the analysis of the luminescence increase of Tb{sup 3+} complexes in the presence of nicotinic acid due to the energy transfer from the excited ligand to the lanthanide ion. It is shown that other potential markers found in M. tuberculosis culture supernatant, such as methyl phenylacetate, p-methyl anisate, methyl nicotinate and 2-methoxy biphenyl, can interfere with nicotinic acid via a competitive absorption of the excitation photons. A new strategy to circumvent these interferences is proposed with an upstream trapping of volatile markers preceding the detection of nicotinic acid in the liquid phase via the luminescence of Tb{sup 3+} complexes. The cost of the method is evaluated and compared with the Xpert MTB/RIF test endorsed by the World Health Organization. - Highlights: • Nicotinic acid, a specific marker of M. tuberculosis, can be detected via luminescence. • The detection limit with a commercial phosphorimeter is 0.4 µmol·L{sup -1}. • Other metabolites of M. tuberculosis can interfere via absorbed excitation light. • The interference can be removed via trapping of the most volatile metabolites. • A breath analysis procedure's cost is compared with the Xpert TBM/RIF test.

  7. Spin Waves in Terbium

    DEFF Research Database (Denmark)

    Jensen, J.; Houmann, Jens Christian Gylden

    1975-01-01

    The selection rules for the linear couplings between magnons and phonons propagating in the c direction of a simple basal-plane hcp ferromagnet are determined by general symmetry considerations. The acoustic-optical magnon-phonon interactions observed in the heavy-rare-earth metals have been expl...... by Liu. The coupled magnon—transverse-phonon system for the c direction of Tb is analyzed in detail, and the strengths of the couplings are deduced as a function of wave vector by combining the experimental studies with the theory....

  8. Spin Waves in Terbium

    DEFF Research Database (Denmark)

    Jensen, J.; Houmann, Jens Christian Gylden; Bjerrum Møller, Hans

    1975-01-01

    The energies of spin waves propagating in the c direction of Tb have been studied by inelastic neutron scattering, as a function of a magnetic field applied along the easy and hard directions in the basal plane, and as a function of temperature. From a general spin Hamiltonian, consistent...... with the symmetry, we deduce the dispersion relation for the spin waves in a basal-plane ferromagnet. This phenomenological spin-wave theory accounts for the observed behavior of the magnon energies in Tb. The two q⃗-dependent Bogoliubov components of the magnon energies are derived from the experimental results...

  9. Sensitized green emission of terbium with dibenzoylmethane and 1, 10 phenanthroline in polyvinyl alcohol and polyvinyl pyrrolidone blends

    Science.gov (United States)

    Kumar, Brijesh; Kaur, Gagandeep; Rai, S. B.

    2017-12-01

    Tb doped polyvinyl alcohol: polyvinyl pyrrolidone blends with dibenzoylmethane (DBM) and 1, 10 Phenanthroline (Phen) have been prepared by solution cast technique. Bond formation amongst the ligands and Tb3 + ions in the doped polymer has been confirmed employing Fourier Transform Infrared (FTIR) techniques. Optical properties of the Tb3 + ions have been investigated using UV-Vis absorption, excitation and fluorescence studies excited by different radiations. Addition of dimethylbenzoate and 1, 10 Phenanthroline to the polymer blend increases the luminescence from Tb3 + ions along with energy transfer from the polymer blend itself. Luminescence decay curve analysis affirms the non-radiative energy transfer from DBM and Phen to Tb3 + ions, which is identified as the reason behind this enhancement. The fluorescence decay time of PVA-PVP host decreases from 6.02 ns to 2.31 ns showing an evidence of energy transfer from the host blend to the complexed Tb ions. Similarly the lifetime of DBM and Phen and both in the blend reduces in the complexed system showing the feasibility of energy transfer from these excited DBM and Phen to Tb3 + and is proposed as the cause of the above observations. These entire phenomena have been explained by the energy level diagram.

  10. Synthesis and crystal structure of terbium(III) meta-oxoborate Tb(BO{sub 2}){sub 3} ({identical_to} TbB{sub 3}O{sub 6}); Synthese und Kristallstruktur von Terbium(III)-meta-Oxoborat Tb(BO{sub 2}){sub 3} ({identical_to} TbB{sub 3}O{sub 6})

    Energy Technology Data Exchange (ETDEWEB)

    Nikelski, Tanja; Schleid, Thomas [Institut fuer Anorganische Chemie der Universitaet Stuttgart (Germany)

    2003-06-01

    The terbium meta-oxoborate Tb(BO{sub 2}){sub 3} ({identical_to} TbB{sub 3}O{sub 6}) is obtained as single crystals by the reaction of terbium, Tb{sub 4}O{sub 7} and TbCl{sub 3} with an excess of B{sub 2}O{sub 3} in gastight sealed platinum ampoules at 950 C after three weeks. The compound appears to be air- and water-resistant and crystallizes as long, thin, colourless needles which tend to growth-twinning due to their marked fibrous habit. The crystal structure of Tb(BO{sub 2}){sub 3} (orthorhombic, Pnma; a = 1598.97(9), b = 741.39(4), c = 1229.58(7) pm; Z = 16) contains strongly corrugated oxoborate layers {sub {infinity}}{sup 2}{l_brace}(BO{sub 2}){sup -}{r_brace} built of vertex-linked [BO{sub 4}]{sup 5-} tetrahedra (d(B-O) = 143 - 154 pm, and angsph;(O-B-O) = 102-115 ) which spread out parallel (100). The four crystallographically different Tb{sup 3+} cations all exhibit coordination numbers of eight towards the oxygen atoms (d(Tb-O) = 228-287 pm). The corresponding metal cation polyhedra [TbO{sub 8}]{sup 13+} too convene to layers (composition: {sub {infinity}}{sup 2}{l_brace}(Tb{sub 2}O{sub 11}){sup 16-}{r_brace}) which are likewise oriented parallel to the (100) plane. (Abstract Copyright [2003], Wiley Periodicals, Inc.) [German] Das Terbium-meta-Oxoborat Tb(BO{sub 2}){sub 3} ({identical_to} TbB{sub 3}O{sub 6}) entsteht einkristallin bei der Reaktion von Terbium, Tb{sub 4}O{sub 7} und TbCl{sub 3} mit einem Ueberschuss von B{sub 2}O{sub 3} in gasdicht verschlossenen Platinampullen nach drei Wochen bei 950 C. Die Verbindung ist luft- und wasserstabil und faellt in langen, duennen, farblosen Nadeln an, die aufgrund ihres ausgepraegt faserigen Habitus zur Wachstumsverzwillingung neigen. Die Kristallstruktur von Tb(BO{sub 2}){sub 3} (orthorhombisch, Pnma; a = 1598, 97(9), b = 741, 39(4), c = 1229, 58(7) pm; Z = 16) enthaelt parallel (100) verlaufende, stark gewellte Oxoborat-Schichten {sub {infinity}}{sup 2}{l_brace}(BO{sub 2}){sup -}{r_brace} aus

  11. pH dependent photophysical studies of new europium and terbium complexes of tripodal ligand: Experimental and semiempirical approach

    Energy Technology Data Exchange (ETDEWEB)

    Akbar, Rifat [Department of Chemistry, Sant Longowal Institute of Engineering & Technology, Longowal, Punjab 148106 (India); Baral, Minati [Department of Chemistry, National Institute of Technology Kurukshetra, Haryana 136119 (India); Kanungo, B K, E-mail: b.kanungo@gmail.com [Department of Chemistry, Sant Longowal Institute of Engineering & Technology, Longowal, Punjab 148106 (India)

    2015-11-15

    The photophysical properties of adduct of a novel nonadentate tripodal ligand, 5,5′-(2-(((8-hydroxyquinolin-5-yl)methylamino)methyl)-2-methylpropane-1, 3-diyl)bis(azanediyl)bis(methylene diquinolin-8-ol, (TAME5OX), with Eu{sup 3+} and Tb{sup 3+} metal ions have been probed for photonics applications. The absorption spectroscopy of these complexes show remarkable spectral changes due to characteristic lanthanide transitions, which support the use of TAME5OX as a sensitive optical pH based sensor to detect Ln{sup 3+} metal ions in biological systems. In addition, these complexes have also been shown to exhibit strong green fluorescence allowing simultaneous sensing within the visible region under physiological pH in competitive medium for both Eu{sup 3+} and Tb{sup 3+} ions. The intense fluorescence from these compounds were revealed to intermittently get quenched under acidic as well as basic conditions due to the photoinduced intramolecular electron transfer from excited 8-hydroxyquinoline (8-HQ) moiety to metal ion, just an opposite process. This renders these compounds the OFF–ON–OFF type of pH-dependent fluorescent sensor. The thermodynamic stability and aqueous coordination chemistry of the chelator with the said lanthanide ions have also been probed by potentiometric, UV–visible and fluorescence spectrophotometric method. TAME5OX has been found to form two protonated complexes [Ln(H{sub 5}L)]{sup 5+} and [Ln(H{sub 4}L)]{sup 4+} below pH 2.5 with both metal ions, which consecutively deprotonates through one proton process with rise of pH. The formation constants (log β{sub 11n}) of neutral complexes have been determined to be 33.51 and 32.16 with pLn (pLn=−log[Ln{sup 3+}]) values of 16.14 and 19.48 for Eu{sup 3+} and Tb{sup 3+} ions, respectively, calculated at pH 7.4, indicating TAME5OX is a good lanthanide synthetic chelator. The emission lifetimes of the Eu{sup 3+} and Tb{sup 3+} complexes recorded in D{sub 2}O and H{sub 2}O suggest the presence

  12. An integrated logic system for time-resolved fluorescent "turn-on" detection of cysteine and histidine base on terbium (III) coordination polymer-copper (II) ensemble.

    Science.gov (United States)

    Xue, Shi-Fan; Lu, Ling-Fei; Wang, Qi-Xian; Zhang, Shengqiang; Zhang, Min; Shi, Guoyue

    2016-09-01

    Cysteine (Cys) and histidine (His) both play indispensable roles in many important biological activities. An enhanced Cys level can result in Alzheimer's and cardiovascular diseases. Likewise, His plays a significant role in the growth and repair of tissues as well as in controlling the transmission of metal elements in biological bases. Therefore, it is meaningful to detect Cys and His simultaneously. In this work, a novel terbium (III) coordination polymer-Cu (II) ensemble (Tb(3+)/GMP-Cu(2+)) was proposed. Guanosine monophosphate (GMP) can self-assemble with Tb(3+) to form a supramolecular Tb(3+) coordination polymer (Tb(3+)/GMP), which can be suited as a time-resolved probe. The fluorescence of Tb(3+)/GMP would be quenched upon the addition of Cu(2+), and then the fluorescence of the as-prepared Tb(3+)/GMP-Cu(2+) ensemble would be restored again in the presence of Cys or His. By incorporating N-Ethylmaleimide and Ni(2+) as masking agents, Tb(3+)/GMP-Cu(2+) was further exploited as an integrated logic system and a specific time-resolved fluorescent "turn-on" assay for simultaneously sensing His and Cys was designed. Meanwhile it can also be used in plasma samples, showing great potential to meet the need of practical application. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. [Studies on luminescence properties of seven ternary complexes of terbium with 1,10-phenanthroline and benzoic acid and its derivatives].

    Science.gov (United States)

    Gao, Zhi-hua; Wang, Shu-ping; Liu, Cui-ge; Ma, Rui-xia; Wang, Rui-fen

    2006-04-01

    Seven ternary complexes of Tb(III) were synthesized with benzoic acid (BA), o-, m-, p-methylbenzoic acid (o-MBA, m-MBA, p-MBA), and o-, m-, p-methoxybenzoic acid (o-MOBA, m-MOBA, p-MOBA) as the first ligand, and 1,10-phenanthroline (phen) as the second ligand. The content of C, H and N were measured by using a Flash-EA model 1112 elemental analyzer. Excitation and luminescence spectra of the title solid complexes were recorded by using a Hitachi F-4500 fluorescence spectrophotometer at room temperature. The effects of different varieties and different positions of replacing benzoic acid as the first ligand on fluorescence properties of the ternary complexes of terbium were discussed. The results indicated that the intensity of 5D4-->7F6 (489 nm) and 5D4-->7F5 (545 nm) of substituting benzoic acid complexes was stronger than benzoic acid. Three ternary complexes of Tb(III) with o-, m-, p-methylbenzoic acid showed emission intensity in the consecution: Tb(o-MBA)3 phenMOBA)3phen x H2O>Tb(m-MOBA)3phen x H2O>Tb(p-MOBA)3 phen.

  14. Terbium-based time-gated Förster resonance energy transfer imaging for evaluating protein-protein interactions on cell membranes.

    Science.gov (United States)

    Lindén, Stina; Singh, Manish Kumar; Wegner, K David; Regairaz, Marie; Dautry, François; Treussart, François; Hildebrandt, Niko

    2015-03-21

    Fluorescence imaging of cells and subcellular compartments is an essential tool to investigate biological processes and to evaluate the development and progression of diseases. In particular, protein-protein interactions can be monitored by Förster resonance energy transfer (FRET) between two proximal fluorophores that are attached to specific recognition biomolecules such as antibodies. We investigated the membrane expression of E- and N-cadherins in three different cell lines used as model systems to study epithelial to mesenchymal transition (EMT) and a possible detection of circulating tumour cells (CTCs). EMT is a key process in cancer metastasis, during which epithelial markers (such as E-cadherin) are down-regulated in the primary tumour whereas mesenchymal markers (such as N-cadherin) are up-regulated, leading to enhanced cell motility, intravasation, and appearance of CTCs. Various FRET donor-acceptor pairs and protein recognition strategies were utilized, in which Lumi4-Tb terbium complexes (Tb) and different organic dyes were conjugated to several distinct E- and N-cadherin-specific antibodies. Pulsed excitation of Tb at low repetition rates (100 Hz) and time-gated (TG) imaging of both the Tb-donor and the dye-acceptor photoluminescence (PL) allowed efficient detection of the EMT markers as well as FRET in the case of sufficient donor-acceptor proximity. Efficient FRET was observed only between two E-cadherin-specific antibodies and further experiments indicated that these antibodies recognized the same E-cadherin molecule, suggesting a limited accessibility of cadherins when they are clustered at adherens junctions. The investigated Tb-to-dye FRET systems provided reduced photobleaching compared to the AlexaFluor 488-568 donor-acceptor pair. Our results demonstrate the applicability and advantages of Tb-based TG FRET for efficient and stable imaging of antibody-antibody interactions on different cell lines. They also reveal the limitations of

  15. A broad G protein-coupled receptor internalization assay that combines SNAP-tag labeling, diffusion-enhanced resonance energy transfer, and a highly emissive terbium cryptate acceptor

    Directory of Open Access Journals (Sweden)

    Angélique eLEVOYE

    2015-11-01

    Full Text Available Although G protein-coupled receptor (GPCR internalization has long been considered a major aspect of the desensitization process that tunes ligand responsiveness, internalization is also involved in receptor resensitization and signaling, as well as the ligand scavenging function of some atypical receptors. Internalization thus contributes to the diversity of GPCR-dependent signaling, and its dynamics and quantification in living cells has generated considerable interest. We developed a robust and sensitive assay to follow and quantify ligand-induced and constitutive GPCR internalization but also receptor recycling in living cells. This assay is based on diffusion-enhanced resonance energy transfer (DERET between cell surface GPCRs labeled with a luminescent terbium cryptate donor and a fluorescein acceptor present in the culture medium. GPCR internalization results in a quantifiable reduction of energy transfer. This method yields a high signal-to-noise ratio due to time-resolved measurements. For various GPCRs belonging to different classes, we demonstrated that constitutive and ligand-induced internalization could be monitored as a function of time and ligand concentration, thus allowing accurate quantitative determination of kinetics of receptor internalization but also half-maximal effective or inhibitory concentrations of compounds. In addition to its selectivity and sensitivity, we provided evidence that DERET-based internalization assay is particularly suitable for characterizing biased ligands. Furthermore, the determination of a Z’-factor value of 0.45 indicates the quality and suitability of DERET-based internalization assay for high-throughput screening (HTS of compounds that may modulate GPCRs internalization.

  16. From lattice ion ion-exchanger to ion memorizing ion-exchanger; Koshi ion ion kokantai kara ion kioku ion kokantai e

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, T. [Yamanashi University, Yamanashi (Japan). Faculty of Engineering

    1996-05-05

    Introduced in this report is the lattice-ion ion exchanger and ion-memorizing ion exchanger that have of late developed into key words. The former is the name given to inorganic ion exchangers, such as hydroxyapatite (hereinafter to be shortened to HAp), which selectively exchange ions for other ions in a water solution, at the ordinary temperature and atmospheric pressure off the common knowledge in inorganic structural chemistry. HAp is an example different from the conventional counter-ion ion exchangers as represented by zeolite, in terms of the order of selectiveness it demonstrates when encountering various cations. HAp and the same with its PO4{sup 3-} ion group replaced with a CO3{sup 2-} or SiO4{sup 4-} group is effective in removing dangerous ions and in sterilizing. The ion-memorizing ion exchanger is a development from the lattice-ion ion exchanger, and is capable of very selectively collecting and removing specified ions as if it remembered the specified ions. The Li- or K-ion-memorizing ion exchanger is a typical example. 17 refs., 4 figs, 4 tabs.

  17. ION VATAMANU

    Directory of Open Access Journals (Sweden)

    l. Povar

    2012-12-01

    Full Text Available Ion Vatamanu was a chemist, writer and public figure. He was equally passionate about both his chosen fields of activity: chemistry and poetry. Chemistry, with its perfect equilibrium of logic and precision, provided inspiration for lyrical creativity, whereas poetry writing enlivened his imagination and passion for chemistry. He loved his parents. He adored his wife Elena, whom he often gifted a sea of flowers. He loved his daughters Mihaela, Mariana, and Leontina. He loved life, and he loved people.

  18. Ion Beam Extraction by Discrete Ion Focusing

    DEFF Research Database (Denmark)

    2010-01-01

    An apparatus (900) and methods are disclosed for ion beam extraction. In an implementation, the apparatus includes a plasma source (or plasma) (802) and an ion extractor (804). The plasma source is adapted to generate ions and the ion extractor is immersed in the plasma source to extract a fraction...... of the generated ions. The ion extractor is surrounded by a space charge (810) formed at least in part by the extracted ions. The ion extractor includes a biased electrode (806) forming an interface with an insulator (808). The interface is customized to form a strongly curved potential distribution (812......) in the space-charge surrounding the ion extractor. The strongly curved potential distribution focuses the extracted ions towards an opening (814) on a surface of the biased electrode thereby resulting in an ion beam....

  19. Sol-gel-derived hybrid materials multi-doped with rare-earth metal ions

    Science.gov (United States)

    Zelazowska, E.; Rysiakiewicz-Pasek, E.; Borczuch-Laczka, M.; Cholewa-Kowalska, K.

    2012-06-01

    Four different hybrid organic-inorganic materials based on TiO2-SiO2 matrices with organic additives and doped with rare-earth metal ions (III) from the group of europium, cerium, terbium, neodymium, dysprosium and samarium, were synthesized by sol-gel method. Tetraethyl orthosilicate, titanium (IV) isopropoxide and organic compounds, such as butyl acrylate, butyl methacrylate, ethyl acetoacetate, ethylene glycol dimethacrylate, ethyl acetate, propylene carbonate, organic solvents and certain inorganic salts were used in the synthesis. The inorganic part of the sols, which were used in the synthesis of all the hybrid materials, was prepared separately and then the organic parts were added. The materials obtained were aged for three weeks at room temperature and then heated in an electric oven for three hours at temperatures of 80 °C-150 °C. Scanning electron microscopy equipped with energy dispersive X-ray spectroscopy (SEM/EDX); X-ray diffraction (XRD); Fourier transform infrared spectroscopy (KBr technique); 29Si magic-angle spinning nuclear magnetic resonance; and fluorescence spectroscopy were used for the examination of morphology, microstructure and luminescence properties, respectively. Photoluminescence properties with relatively intense narrow emission lines of Tb, Eu, Dy, Nd, Sm respectively to the RE-ions doping, were observed for all the hybrid materials.

  20. Picomolar traces of americium(III) introduce drastic changes in the structural chemistry of terbium(III). A break in the ''gadolinium break''

    Energy Technology Data Exchange (ETDEWEB)

    Welch, Jan M. [TU Wien, Atominstitut, Vienna (Austria); Mueller, Danny; Knoll, Christian; Wilkovitsch, Martin; Weinberger, Peter [TU Wien, Institute of Applied Synthetic Chemistry, Vienna (Austria); Giester, Gerald [University of Vienna, Institute of Mineralogy and Crystallography, Vienna (Austria); Ofner, Johannes; Lendl, Bernhard [TU Wien, Institute of Chemical Technologies and Analytics, Vienna (Austria); Steinhauser, Georg [Leibniz Universitaet Hannover, Institute of Radioecology and Radiation Protection (Germany)

    2017-10-16

    The crystallization of terbium 5,5{sup '}-azobis[1H-tetrazol-1-ide] (ZT) in the presence of trace amounts (ca. 50 Bq, ca. 1.6 pmol) of americium results in 1) the accumulation of the americium tracer in the crystalline solid and 2) a material that adopts a different crystal structure to that formed in the absence of americium. Americium-doped [Tb(Am)(H{sub 2}O){sub 7}ZT]{sub 2} ZT.10 H{sub 2}O is isostructural to light lanthanide (Ce-Gd) 5,5{sup '}-azobis[1H-tetrazol-1-ide] compounds, rather than to the heavy lanthanide (Tb-Lu) 5,5{sup '}-azobis[1H-tetrazol-1-ide] (e.g., [Tb(H{sub 2}O){sub 8}]{sub 2}ZT{sub 3}.6 H{sub 2}O) derivatives. Traces of Am seem to force the Tb compound into a structure normally preferred by the lighter lanthanides, despite a 10{sup 8}-fold Tb excess. The americium-doped material was studied by single-crystal X-ray diffraction, vibrational spectroscopy, radiochemical neutron activation analysis, and scanning electron microscopy. In addition, the inclusion properties of terbium 5,5{sup '}-azobis[1H-tetrazol-1-ide] towards americium were quantified, and a model for the crystallization process is proposed. (copyright 2017 Wiley-VCH Verlag GmbH and Co. KGaA, Weinheim)

  1. Gas phase ion chemistry

    CERN Document Server

    Bowers, Michael T

    1979-01-01

    Gas Phase Ion Chemistry, Volume 1 covers papers on the advances of gas phase ion chemistry. The book discusses the advances in flow tubes and the measurement of ion-molecule rate coefficients and product distributions; the ion chemistry of the earth's atmosphere; and the classical ion-molecule collision theory. The text also describes statistical methods in reaction dynamics; the state selection by photoion-photoelectron coincidence; and the effects of temperature and pressure in the kinetics of ion-molecule reactions. The energy distribution in the unimolecular decomposition of ions, as well

  2. EUV spectra of Gd and Tb ions excited in laser-produced and vacuum spark plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Churilov, S S; Kildiyarova, R R; Ryabtsev, A N; Sadovsky, S V [Establishment of the Russian Academy of Sciences Institute of Spectroscopy RAS, Troitsk, Moscow region 142190 (Russian Federation)], E-mail: ryabtsev@isan.troitsk.ru

    2009-10-15

    Extreme UV spectra of the gadolinium and terbium ions excited in the laser-produced plasma and vacuum spark sources were recorded in the 40-120 A region and investigated on the basis of the Hartree-Fock calculations using Cowan code. The intense peaks in the 65-75 A region of the vacuum spark spectra were interpreted as a manifold of the 4d{sup 10}4f{sup m}-4d{sup 9}4f{sup m+1} transitions in the ions with a partially filled 4f shell. The drastic narrowing of these peaks was observed in the spectra of the laser-produced plasma. It was explained by a change of the 4d{sup 10}4f{sup m}-4d{sup 9}4f{sup m+1} (m>2) transition arrays mostly contributing to the intensity of the peaks in the vacuum spark spectra for the 4-4 transitions in the simplest spectra of the 4p{sup 6}4d{sup k} (k=8-10) and 4d{sup 10}4f{sup m} (m=1-2) ground configuration ions predominantly excited in hotter laser-produced plasma. The most intense lines of the 4d{sup 10}4f{sup 2}-4d{sup 10}4f5d transitions in the Gd XVII and Tb XVIII spectra were classified for the first time.

  3. Microfabricated ion frequency standard

    Science.gov (United States)

    Schwindt, Peter; Biedermann, Grant; Blain, Matthew G.; Stick, Daniel L.; Serkland, Darwin K.; Olsson, III, Roy H.

    2010-12-28

    A microfabricated ion frequency standard (i.e. an ion clock) is disclosed with a permanently-sealed vacuum package containing a source of ytterbium (Yb) ions and an octupole ion trap. The source of Yb ions is a micro-hotplate which generates Yb atoms which are then ionized by a ultraviolet light-emitting diode or a field-emission electron source. The octupole ion trap, which confines the Yb ions, is formed from suspended electrodes on a number of stacked-up substrates. A microwave source excites a ground-state transition frequency of the Yb ions, with a frequency-doubled vertical-external-cavity laser (VECSEL) then exciting the Yb ions up to an excited state to produce fluorescent light which is used to tune the microwave source to the ground-state transition frequency, with the microwave source providing a precise frequency output for the ion clock.

  4. Radioactive Ion Sources

    OpenAIRE

    Stora, T

    2014-01-01

    This chapter provides an overview of the basic requirements for ion sources designed and operated in radioactive ion beam facilities. The facilities where these sources are operated exploit the isotope separation online (ISOL) technique, in which a target is combined with an ion source to maximize the secondary beam intensity and chemical element selectivity. Three main classes of sources are operated, namely surface-type ion sources, arc discharge-type ion sources, and finally radio-frequenc...

  5. The effect of core and lanthanide ion dopants in sodium fluoride-based nanocrystals on phagocytic activity of human blood leukocytes

    Energy Technology Data Exchange (ETDEWEB)

    Sojka, Bartlomiej [Wroclaw University of Science and Technology, Department of Experimental Physics (Poland); Liskova, Aurelia; Kuricova, Miroslava [Slovak Medical University, Medical Faculty, Department of Immunology and Immunotoxicology (Slovakia); Banski, Mateusz; Misiewicz, Jan [Wroclaw University of Science and Technology, Department of Experimental Physics (Poland); Dusinska, Maria [Norwegian Institute for Air Research, Health Effects Laboratory, Department of Environmental Chemistry (Norway); Horvathova, Mira; Ilavska, Silvia; Szabova, Michaela [Slovak Medical University, Medical Faculty, Department of Immunology and Immunotoxicology (Slovakia); Rollerova, Eva [Slovak Medical University, Faculty of Public Health, Department of Toxicology (Slovakia); Podhorodecki, Artur, E-mail: artur.p.podhorodecki@pwr.edu.pl [Wroclaw University of Science and Technology, Department of Experimental Physics (Poland); Tulinska, Jana, E-mail: jana.tulinska@szu.sk [Slovak Medical University, Medical Faculty, Department of Immunology and Immunotoxicology (Slovakia)

    2017-02-15

    Sodium fluoride-based β-NaLnF4 nanoparticles (NPs) doped with lanthanide ions are promising materials for application as luminescent markers in bio-imaging. In this work, the effect of NPs doped with yttrium (Y), gadolinium (Gd), europium (Eu), thulium (Tm), ytterbium (Yb) and terbium (Tb) ions on phagocytic activity of monocytes and granulocytes and the respiratory burst was examined. The surface functionalization of <10-nm NPs was performed according to our variation of patent pending ligand exchange method that resulted in meso-2,3-dimercaptosuccinic acid (DMSA) molecules on their surface. Y-core-based NCs were doped with Eu ions, which enabled them to be excited with UV light wavelengths. Cultures of human peripheral blood (n = 8) were in vitro treated with five different concentrations of eight NPs for 24 h. In summary, neither type of nanoparticles is found toxic with respect to conducted test; however, some cause toxic effects (they have statistically significant deviations compared to reference) in some selected doses tested. Both core types of NPs (Y-core and Gd-core) impaired the phagocytic activity of monocytes the strongest, having minimal or none whatsoever influence on granulocytes and respiratory burst of phagocytic cells. The lowest toxicity was observed in Gd-core, Yb, Tm dopants and near-infrared nanoparticles. Clear dose-dependent effect of NPs on phagocytic activity of leukocytes and respiratory burst of cells was observed for limited number of samples.

  6. Ion recombination correction in carbon ion beams.

    Science.gov (United States)

    Rossomme, S; Hopfgartner, J; Lee, N D; Delor, A; Thomas, R A S; Romano, F; Fukumura, A; Vynckier, S; Palmans, H

    2016-07-01

    In this work, ion recombination is studied as a function of energy and depth in carbon ion beams. Measurements were performed in three different passively scattered carbon ion beams with energies of 62 MeV/n, 135 MeV/n, and 290 MeV/n using various types of plane-parallel ionization chambers. Experimental results were compared with two analytical models for initial recombination. One model is generally used for photon beams and the other model, developed by Jaffé, takes into account the ionization density along the ion track. An investigation was carried out to ascertain the effect on the ion recombination correction with varying ionization chamber orientation with respect to the direction of the ion tracks. The variation of the ion recombination correction factors as a function of depth was studied for a Markus ionization chamber in the 62 MeV/n nonmodulated carbon ion beam. This variation can be related to the depth distribution of linear energy transfer. Results show that the theory for photon beams is not applicable to carbon ion beams. On the other hand, by optimizing the value of the ionization density and the initial mean-square radius, good agreement is found between Jaffé's theory and the experimental results. As predicted by Jaffé's theory, the results confirm that ion recombination corrections strongly decrease with an increasing angle between the ion tracks and the electric field lines. For the Markus ionization chamber, the variation of the ion recombination correction factor with depth was modeled adequately by a sigmoid function, which is approximately constant in the plateau and strongly increasing in the Bragg peak region to values of up to 1.06. Except in the distal edge region, all experimental results are accurately described by Jaffé's theory. Experimental results confirm that ion recombination in the investigated carbon ion beams is dominated by initial recombination. Ion recombination corrections are found to be significant and cannot be

  7. Ions and light

    CERN Document Server

    Bowers, Michael T

    2013-01-01

    Gas Phase Ion Chemistry, Volume 3: Ions and Light discusses how ions are formed by electron impact, ion-molecule reactions, or electrical discharge. This book discusses the use of light emitted by excited molecules to characterize either the chemistry that formed the excited ion, the structure of the excited ion, or both.Organized into 10 chapters, this volume begins with an overview of the extension of the classical flowing afterglow technique to include infrared and chemiluminescence and laser-induced fluorescence detection. This text then examines the experiments involving molecules that ar

  8. Radioactive Ion Sources

    CERN Document Server

    Stora, T

    2013-01-01

    This chapter provides an overview of the basic requirements for ion sources designed and operated in radioactive ion beam facilities. The facilities where these sources are operated exploit the isotope separation online (ISOL) technique, in which a target is combined with an ion source to maximize the secondary beam intensity and chemical element selectivity. Three main classes of sources are operated, namely surface-type ion sources, arc discharge-type ion sources, and finally radio-frequency-heated plasma-type ion sources.

  9. IBC - ION BEAM CENTER

    Directory of Open Access Journals (Sweden)

    Johannes von Borany

    2017-12-01

    Full Text Available In the Ion Beam Center (IBC, various set-ups – electrostatic accelerators, ion implanters, plasma-based ion implantation equipment, low-energy ion tools, an ion microscope etc. – are combined into a unique facility for research and applications using ion beams. Almost all ions from stable chemical nuclides are available in the ion energy range from 10 eV to about 60 MeV. In addition to broad beams, also focused (down to 1 nm and highly-charged (charge state up to 45+ ion beams, or ions extracted from a plasma can be provided. In total, the IBC operates more than 30 dedicated tools or beamline end-stations. The specific expertise of IBC is the modification and analysis of solids by energetic ions aimed to develop novel materials for information technology, electronics or energy systems. In addition, ion beam analysis techniques became of increasing importance for interdisciplinary fields like geochemistry, climate or environmental research and resources technology. Special add-on services offered ensure a successful realization of user experiments. Based on a long-term expertise, specific equipment and common commercial procedures, the IBC is strongly active in the use of ion beam techniques for industrial applications aimed to initiate valuable product innovation.

  10. Ion mobility spectrometry

    CERN Document Server

    Eiceman, GA

    2005-01-01

    Key Developments for Faster, More Precise Detection Capabilities Driven by the demand for the rapid and advanced detection of explosives, chemical and biological warfare agents, and narcotics, ion mobility spectrometry (IMS) undergone significant refinements in technology, computational capabilities, and understanding of the principles of gas phase ion chemistry and mobility. Beginning with a thorough discussion of the fundamental theories and physics of ion mobility, Ion Mobility Spectrometry, Second Edition describes the recent advances in instrumentation and newly

  11. Gas phase ion chemistry

    CERN Document Server

    Bowers, Michael T

    1979-01-01

    Gas Phase Ion Chemistry, Volume 2 covers the advances in gas phase ion chemistry. The book discusses the stabilities of positive ions from equilibrium gas-phase basicity measurements; the experimental methods used to determine molecular electron affinities, specifically photoelectron spectroscopy, photodetachment spectroscopy, charge transfer, and collisional ionization; and the gas-phase acidity scale. The text also describes the basis of the technique of chemical ionization mass spectrometry; the energetics and mechanisms of unimolecular reactions of positive ions; and the photodissociation

  12. Negative Ion Density Fronts

    Energy Technology Data Exchange (ETDEWEB)

    Igor Kaganovich

    2000-12-18

    Negative ions tend to stratify in electronegative plasmas with hot electrons (electron temperature Te much larger than ion temperature Ti, Te > Ti ). The boundary separating a plasma containing negative ions, and a plasma, without negative ions, is usually thin, so that the negative ion density falls rapidly to zero-forming a negative ion density front. We review theoretical, experimental and numerical results giving the spatio-temporal evolution of negative ion density fronts during plasma ignition, the steady state, and extinction (afterglow). During plasma ignition, negative ion fronts are the result of the break of smooth plasma density profiles during nonlinear convection. In a steady-state plasma, the fronts are boundary layers with steepening of ion density profiles due to nonlinear convection also. But during plasma extinction, the ion fronts are of a completely different nature. Negative ions diffuse freely in the plasma core (no convection), whereas the negative ion front propagates towards the chamber walls with a nearly constant velocity. The concept of fronts turns out to be very effective in analysis of plasma density profile evolution in strongly non-isothermal plasmas.

  13. Ion-kill dosimetry

    Science.gov (United States)

    Katz, R.; Cucinotta, F. A.; Fromm, M.; Chambaudet, A.

    2001-01-01

    Unanticipated late effects in neutron and heavy ion therapy, not attributable to overdose, imply a qualitative difference between low and high LET therapy. We identify that difference as 'ion kill', associated with the spectrum of z/beta in the radiation field, whose measurement we label 'ion-kill dosimetry'.

  14. Enhanced ion acoustic fluctuations and ion outflows

    Directory of Open Access Journals (Sweden)

    F. R. E. Forme

    1999-02-01

    Full Text Available A number of observations showing enhanced ion acoustic echoes observed by means of incoherent scatter radars have been reported in the literature. The received power is extremely enhanced by up to 1 or 2 orders of magnitude above usual values, and it is mostly contained in one of the two ion acoustic lines. This spectral asymmetry and the intensity of the received signal cannot be resolved by the standard analysis procedure and often causes its failure. As a result, and in spite of a very clear spectral signature, the analysis is unable to fit the plasma parameters inside the regions of ion acoustic turbulence. We present European Incoherent Scatter radar (EISCAT observations of large ion outflows associated with the simultaneous occurrence of enhanced ion acoustic echoes. The ion fluxes can reach 1014 m-2 s-1 at 800 km altitude. From the very clear spectral signatures of these echoes, a method is presented to extract estimates of the electron temperature and the ion drift within the turbulent regions. It is shown that the electron gas is strongly heated up to 11 000 K. Also electron temperature gradients of about 0.02 K/m exist. Finally, the estimates of the electron temperature and of the ion drift are used to study the possible implications for the plasma transport inside turbulent regions. It is shown that strong electron temperature gradients cause enhancement of the ambipolar electric field and can account for the observed ion outflows.Key words. Ionosphere (auroral ionosphere; ionosphere · magnetosphere interactions; plasma waves and instabilities.

  15. Vacuum Arc Ion Sources

    CERN Document Server

    Brown, I.

    2013-12-16

    The vacuum arc ion source has evolved into a more or less standard laboratory tool for the production of high-current beams of metal ions, and is now used in a number of different embodiments at many laboratories around the world. Applications include primarily ion implantation for material surface modification research, and good performance has been obtained for the injection of high-current beams of heavy-metal ions, in particular uranium, into particle accelerators. As the use of the source has grown, so also have the operational characteristics been improved in a variety of different ways. Here we review the principles, design, and performance of vacuum arc ion sources.

  16. Ion cyclotron resonance cell

    Science.gov (United States)

    Weller, R.R.

    1995-02-14

    An ion cyclotron resonance cell is disclosed having two adjacent sections separated by a center trapping plate. The first section is defined by the center trapping plate, a first end trapping plate, and excitation and detector electrodes. The second section includes a second end trapping plate spaced apart from the center plate, a mirror, and an analyzer. The analyzer includes a wavelength-selective light detector, such as a detector incorporating an acousto-optical device (AOD) and a photodetector. One or more ion guides, grounded plates with holes for the ion beam, are positioned within the vacuum chamber of the mass spectrometer between the ion source and the cell. After ions are trapped and analyzed by ion cyclotron resonance techniques in the first section, the ions of interest are selected according to their mass and passed into the second section for optical spectroscopic studies. The trapped ions are excited by light from a laser and caused thereby to fluoresce. The fluorescent light emitted by the excited ions is reflected by the mirror and directed onto the detector. The AOD is scanned, and the photodetector output is recorded and analyzed. The ions remain in the second section for an extended period, enabling multiple studies to be carried out on the same ensemble of ions. 5 figs.

  17. Crater formation by single ions, cluster ions and ion "showers"

    CERN Document Server

    Djurabekova, Flyura; Timko, Helga; Nordlund, Kai; Calatroni, Sergio; Taborelli, Mauro; Wuensch, Walter

    2011-01-01

    The various craters formed by giant objects, macroscopic collisions and nanoscale impacts exhibit an intriguing resemblance in shapes. At the same time, the arc plasma built up in the presence of sufficiently high electric fields at close look causes very similar damage on the surfaces. Although the plasma–wall interaction is far from a single heavy ion impact over dense metal surfaces or the one of a cluster ion, the craters seen on metal surfaces after a plasma discharge make it possible to link this event to the known mechanisms of the crater formations. During the plasma discharge in a high electric field the surface is subject to high fluxes (~1025 cm-2s-1) of ions with roughly equal energies typically of the order of a few keV. To simulate such a process it is possible to use a cloud of ions of the same energy. In the present work we follow the effect of such a flux of ions impinging the surface in the ‘‘shower’’ manner, to find the transition between the different mechanisms of crater formati...

  18. Microfabricated ion trap array

    Science.gov (United States)

    Blain, Matthew G [Albuquerque, NM; Fleming, James G [Albuquerque, NM

    2006-12-26

    A microfabricated ion trap array, comprising a plurality of ion traps having an inner radius of order one micron, can be fabricated using surface micromachining techniques and materials known to the integrated circuits manufacturing and microelectromechanical systems industries. Micromachining methods enable batch fabrication, reduced manufacturing costs, dimensional and positional precision, and monolithic integration of massive arrays of ion traps with microscale ion generation and detection devices. Massive arraying enables the microscale ion traps to retain the resolution, sensitivity, and mass range advantages necessary for high chemical selectivity. The reduced electrode voltage enables integration of the microfabricated ion trap array with on-chip circuit-based rf operation and detection electronics (i.e., cell phone electronics). Therefore, the full performance advantages of the microfabricated ion trap array can be realized in truly field portable, handheld microanalysis systems.

  19. Crystal structure of a mixed-ligand terbium(III coordination polymer containing oxalate and formate ligands, having a three-dimensional fcu topology

    Directory of Open Access Journals (Sweden)

    Chainok Kittipong

    2016-01-01

    Full Text Available The title compound, poly[(μ3-formato(μ4-oxalatoterbium(III], [Tb(CHO2(C2O4]n, is a three-dimensional coordination polymer, and is isotypic with the LaIII, CeIII and SmIII analogues. The asymmetric unit contains one TbIII ion, one formate anion (CHO2− and half of an oxalate anion (C2O42−, the latter being completed by application of inversion symmetry. The TbIII ion is nine-coordinated in a distorted tricapped trigonal–prismatic manner by two chelating carboxylate groups from two C2O42− ligands, two carboxylate oxygen atoms from another two C2O42− ligands and three oxygen atoms from three CHO2− ligands, with the Tb—O bond lengths and the O—Tb—O bond angles ranging from 2.4165 (19 to 2.478 (3 Å and 64.53 (6 to 144.49 (4°, respectively. The CHO2− and C2O42− anions adopt μ3-bridging and μ4-chelating-bridging coordination modes, respectively, linking adjacent TbIII ions into a three-dimensional 12-connected fcu topology with point symbol (324.436.56. The title compound exhibits thermal stability up to 623 K, and also displays strong green photoluminescence in the solid state at room temperature.

  20. Chiral recognition of proteins having L-histidine residues on the surface with lanthanide ion complex incorporated-molecularly imprinted fluorescent nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    Uzun, Lokman, E-mail: lokman@hacettepe.edu.tr [Hacettepe University, Department of Chemistry, 06381, Ankara (Turkey); Uzek, Recep; Şenel, Serap [Hacettepe University, Department of Chemistry, 06381, Ankara (Turkey); Say, Ridvan [Anadolu University, Department of Chemistry, 26470, Eskisehir (Turkey); Denizli, Adil [Hacettepe University, Department of Chemistry, 06381, Ankara (Turkey)

    2013-08-01

    In this study, lanthanide ion complex incorporated molecularly imprinted fluorescent nanoparticles were synthesized. A combination of three novel approaches was applied for the purpose. First, lanthanide ions [Terbium(III)] were complexed with N-methacryloyl-L-histidine (MAH), polymerizable derivative of L-histidine amino acid, in order to incorporate the complex directly into the polymeric backbone. At the second stage, L-histidine molecules imprinted nanoparticles were utilized instead of whole protein imprinting in order to avoid whole drawbacks such as fragility, complexity, denaturation tendency, and conformation dependency. At the third stage following the first two steps mentioned above, imprinted L-histidine was coordinated with cupric ions [Cu(II)] to conduct the study under mild conditions. Then, molecularly imprinted fluorescent nanoparticles synthesized were used for L-histidine adsorption from aqueous solution to optimize conditions for adsorption and fluorimetric detection. Finally, usability of nanoparticles was investigated for chiral biorecognition using stereoisomer, D-histidine, racemic mixture, D,L-histidine, proteins with surface L-histidine residue, lysozyme, cytochrome C, or without ribonuclease A. The results revealed that the proposed polymerization strategy could make significant contribution to the solution of chronic problems of fluorescent component introduction into polymers. Additionally, the fluorescent nanoparticles reported here could be used for selective separation and fluorescent monitoring purposes. Highlights: • Lanthanide ion complex incorporated molecularly imprinted fluorescent nanoparticles • Direct incorporation of the fluorescent complex into polymeric backbone. • Imprinting by assistance of cupric ion coordination into nanoparticles • Evaluation of the chiral biorecognition ability of nanoparticles • Simultaneous selective separation and fluorescent monitoring.

  1. Single ion TRICS

    Energy Technology Data Exchange (ETDEWEB)

    Bruce, J.A.; Anderson, G.A.; Hofstadler, S.A.; Smith, R.D. [Pacific Northwest Lab., Richland, WA (United States)

    1994-12-31

    A Fourier transform ion cyclotron resonance (FTICR) mass spectrometer has been used to trap individual, multiply charged ions of high molecular weight polymers, such as poly(ethylene oxide) (PEG). Accurate mass measurements of electrosprayed ions, or other multiply charge ions, requires determination of charge state. Trapping two or more large individual ions with the same mass, differing only by one additional charge is highly unlikely. Thus, exact mass assignments based on the measurement of charge state spacing to determine molecular weight is not feasible. Therefore, a new scheme was required to determine the mass of individual ions based on the observation of m/z shifts (i.e., cyclotron frequency shifts) resulting from reactions such as charge exchange or the adduction of a substance of a known mass. A new technique for mass determination of individual ions has been developed based on the observation of cyclotron frequency shifts during the time-domain acquisition period. This Time Resolved Ion Correlation (TRIC) technique allows reactant and product ions to be correlated with confidence by segmented Fourier transformation and comparison of extracted time-domain signals, and provides the basis for simultaneously studying a moderate number of ions.

  2. Macromolecular ion accelerator.

    Science.gov (United States)

    Hsu, Yun-Fei; Lin, Jung-Lee; Lai, Szu-Hsueh; Chu, Ming-Lee; Wang, Yi-Sheng; Chen, Chung-Hsuan

    2012-07-03

    Presented herein are the development of macromolecular ion accelerator (MIA) and the results obtained by MIA. This new instrument utilizes a consecutive series of planar electrodes for the purpose of facilitating stepwise acceleration. Matrix-assisted laser desorption/ionization (MALDI) is employed to generate singly charged macromolecular ions. A regular Z-gap microchannel plate (MCP) detector is mounted at the end of the accelerator to record the ion signals. In this work, we demonstrated the detection of ions with the mass-to-charge (m/z) ratio reaching 30,000,000. Moreover, we showed that singly charged biomolecular ions can be accelerated with the voltage approaching 1 MV, offering the evidence that macromolecular ions can possess much higher kinetic energy than ever before.

  3. Ion photon emission microscope

    Science.gov (United States)

    Doyle, Barney L.

    2003-04-22

    An ion beam analysis system that creates microscopic multidimensional image maps of the effects of high energy ions from an unfocussed source upon a sample by correlating the exact entry point of an ion into a sample by projection imaging of the ion-induced photons emitted at that point with a signal from a detector that measures the interaction of that ion within the sample. The emitted photons are collected in the lens system of a conventional optical microscope, and projected on the image plane of a high resolution single photon position sensitive detector. Position signals from this photon detector are then correlated in time with electrical effects, including the malfunction of digital circuits, detected within the sample that were caused by the individual ion that created these photons initially.

  4. Materials analysis fast ions

    CERN Document Server

    Denker, A; Rauschenberg, J; Röhrich, J; Strub, E

    2006-01-01

    Materials analysis with ion beams exploits the interaction of ions with the electrons and nuclei in the sample. Among the vast variety of possible analytical techniques available with ion beams we will restrain to ion beam analysis with ion beams in the energy range from one to several MeV per mass unit. It is possible to use either the back-scattered projectiles (RBS – Rutherford Back Scattering) or the recoiled atoms itself (ERDA – Elastic Recoil Detection Analysis) from the elastic scattering processes. These techniques allow the simultaneous and absolute determination of stoichiometry and depth profiles of the detected elements. The interaction of the ions with the electrons in the sample produces holes in the inner electronic shells of the sample atoms, which recombine and emit X-rays characteristic for the element in question. Particle Induced X-ray Emission (PIXE) has shown to be a fast technique for the analysis of elements with an atomic number above 11.

  5. Lithium-ion batteries

    CERN Document Server

    Yoshio, Masaki; Kozawa, Akiya

    2010-01-01

    This book is a compilation of up-to-date information relative to Li-Ion technology. It provides the reader with a single source covering all important aspects of Li-Ion battery operations. It fills the gap between the old original Li-Ion technology and present state of the technology that has developed into a high state of practice. The book is designed to provide a single source for an up-to-date description of the technology associated with the Li-Ion battery industry. It will be useful to researchers interested in energy conversion for the direct conversion of chemical energy into electrica

  6. Correlation ion mobility spectroscopy

    Science.gov (United States)

    Pfeifer, Kent B [Los Lunas, NM; Rohde, Steven B [Corrales, NM

    2008-08-26

    Correlation ion mobility spectrometry (CIMS) uses gating modulation and correlation signal processing to improve IMS instrument performance. Closely spaced ion peaks can be resolved by adding discriminating codes to the gate and matched filtering for the received ion current signal, thereby improving sensitivity and resolution of an ion mobility spectrometer. CIMS can be used to improve the signal-to-noise ratio even for transient chemical samples. CIMS is especially advantageous for small geometry IMS drift tubes that can otherwise have poor resolution due to their small size.

  7. Ion-beam technologies

    Energy Technology Data Exchange (ETDEWEB)

    Fenske, G.R. [Argonne National Lab., IL (United States)

    1993-01-01

    This compilation of figures and diagrams reviews processes for depositing diamond/diamond-like carbon films. Processes addressed are chemical vapor deposition (HFCVD, PACVD, etc.), plasma vapor deposition (plasma sputtering, ion beam sputtering, evaporation, etc.), low-energy ion implantation, and hybrid processes (biased sputtering, IBAD, biased HFCVD, etc.). The tribological performance of coatings produced by different means is discussed.

  8. Classification of Ion Sources

    OpenAIRE

    Scrivens, R.

    2014-01-01

    In this chapter, the anatomy of an ion source is briefly described, as well as a few features of particle motion in electric and magnetic fields, and of particle dynamics and plasmas. Using this information, different types of ion sources are described, highlighting their main mode of operation.

  9. Cooperativity in ion hydration

    NARCIS (Netherlands)

    Tielrooij, K.J.; Garcia-Araez, N.; Bonn, M.; Bakker, H.J.

    2010-01-01

    Despite prolonged scientific efforts to unravel the effects of ions on the structure and dynamics of water, many open questions remain, in particular concerning the spatial extent of this effect (i.e., the number of water molecules affected) and the origin of ion-specific effects. A combined

  10. CLASSICS The Ions

    Indian Academy of Sciences (India)

    Arrhenius theory of electrolytic dissociation, viz., in general, salts in solution dissociate to give ions. Ostwald, in 1888 gave a quantitative description of the dissociation, which was very useful in understanding the physical chemistry of solutions. The following portion 'The Ions' is from the book The Fundamental Principles of.

  11. Ion mobility sensor system

    Science.gov (United States)

    Xu, Jun; Watson, David B.; Whitten, William B.

    2013-01-22

    An ion mobility sensor system including an ion mobility spectrometer and a differential mobility spectrometer coupled to the ion mobility spectrometer. The ion mobility spectrometer has a first chamber having first end and a second end extending along a first direction, and a first electrode system that generates a constant electric field parallel to the first direction. The differential mobility spectrometer includes a second chamber having a third end and a fourth end configured such that a fluid may flow in a second direction from the third end to the fourth end, and a second electrode system that generates an asymmetric electric field within an interior of the second chamber. Additionally, the ion mobility spectrometer and the differential mobility spectrometer form an interface region. Also, the first end and the third end are positioned facing one another so that the constant electric field enters the third end and overlaps the fluid flowing in the second direction.

  12. Lipid Ion Channels

    CERN Document Server

    Heimburg, Thomas

    2010-01-01

    The interpretation electrical phenomena in biomembranes is usually based on the assumption that the experimentally found discrete ion conduction events are due to a particular class of proteins called ion channels while the lipid membrane is considered being an inert electrical insulator. The particular protein structure is thought to be related to ion specificity, specific recognition of drugs by receptors and to macroscopic phenomena as nerve pulse propagation. However, lipid membranes in their chain melting regime are known to be highly permeable to ions, water and small molecules, and are therefore not always inert. In voltage-clamp experiments one finds quantized conduction events through protein-free membranes in their melting regime similar to or even undistinguishable from those attributed to proteins. This constitutes a conceptual problem for the interpretation of electrophysiological data obtained from biological membrane preparations. Here, we review the experimental evidence for lipid ion channels...

  13. Ion Implantation of Polymers

    DEFF Research Database (Denmark)

    Popok, Vladimir

    2012-01-01

    The current paper presents a state-of-the-art review in the field of ion implantation of polymers. Numerous published studies of polymers modified by ion beams are analysed. General aspects of ion stopping, latent track formation and changes of structure and composition of organic materials...... are discussed. Related to that, the effects of radiothermolysis, degassing and carbonisation are considered. Specificity of depth distributions of implanted into polymers impurities is analysed and the case of high-fluence implantation is emphasised. Within rather broad topic of ion bombardment, the focus...... is put on the low-energy implantation of metal ions causing the nucleation and growth of nanoparticles in the shallow polymer layers. Electrical, optical and magnetic properties of metal/polymer composites are under the discussion and the approaches towards practical applications are overviewed....

  14. Ion channel pharmacology.

    Science.gov (United States)

    Camerino, Diana Conte; Tricarico, Domenico; Desaphy, Jean-François

    2007-04-01

    Because ion channels are involved in many cellular processes, drugs acting on ion channels have long been used for the treatment of many diseases, especially those affecting electrically excitable tissues. The present review discusses the pharmacology of voltage-gated and neurotransmitter-gated ion channels involved in neurologic diseases, with emphasis on neurologic channelopathies. With the discovery of ion channelopathies, the therapeutic value of many basic drugs targeting ion channels has been confirmed. The understanding of the genotype-phenotype relationship has highlighted possible action mechanisms of other empirically used drugs. Moreover, other ion channels have been pinpointed as potential new drug targets. With regards to therapy of channelopathies, experimental investigations of the intimate drug-channel interactions have demonstrated that channel mutations can either increase or decrease affinity for the drug, modifying its potential therapeutic effect. Together with the discovery of channel gene polymorphisms that may affect drug pharmacodynamics, these findings highlight the need for pharmacogenetic research to allow identification of drugs with more specific effects on channel isoforms or mutants, to increase efficacy and reduce side effects. With a greater understanding of channel genetics, structure, and function, together with the identification of novel primary and secondary channelopathies, the number of ion channel drugs for neurologic channelopathies will increase substantially.

  15. Ion optics of RHIC electron beam ion source.

    Science.gov (United States)

    Pikin, A; Alessi, J; Beebe, E; Kponou, A; Okamura, M; Raparia, D; Ritter, J; Tan, Y; Kuznetsov, G

    2012-02-01

    RHIC electron beam ion source has been commissioned to operate as a versatile ion source on RHIC injection facility supplying ion species from He to Au for Booster. Except for light gaseous elements RHIC EBIS employs ion injection from several external primary ion sources. With electrostatic optics fast switching from one ion species to another can be done on a pulse to pulse mode. The design of an ion optical structure and the results of simulations for different ion species are presented. In the choice of optical elements special attention was paid to spherical aberrations for high-current space charge dominated ion beams. The combination of a gridded lens and a magnet lens in LEBT provides flexibility of optical control for a wide range of ion species to satisfy acceptance parameters of RFQ. The results of ion transmission measurements are presented.

  16. Ion dynamics during seizures

    Directory of Open Access Journals (Sweden)

    Joseph Valentino Raimondo

    2015-10-01

    Full Text Available Changes in membrane voltage brought about by ion fluxes through voltage and transmitter-gated channels represent the basis of neural activity. As such, electrochemical gradients across the membrane determine the direction and driving force for the flow of ions and are therefore crucial in setting the properties of synaptic transmission and signal propagation. Ion concentration gradients are established by a variety of mechanisms, including specialised transporter proteins. However, transmembrane gradients can be affected by ionic fluxes through channels during periods of elevated neural activity, which in turn are predicted to influence the properties of on-going synaptic transmission. Such activity-induced changes to ion concentration gradients are a feature of both physiological and pathological neural processes. An epileptic seizure is an example of severely perturbed neural activity, which is accompanied by pronounced changes in intracellular and extracellular ion concentrations. Appreciating the factors that contribute to these ion dynamics is critical if we are to understand how a seizure event evolves and is sustained and terminated by neural tissue. Indeed, this issue is of significant clinical importance as status epilepticus – a type of seizure that does not stop of its own accord – is a life-threatening medical emergency. In this review we explore how the transmembrane concentration gradient of the six major ions (K+, Na+, Cl-, Ca2+, H+ and HCO3- is altered during an epileptic seizure. We will first examine each ion individually, before describing how multiple interacting mechanisms between ions might contribute to concentration changes and whether these act to prolong or terminate epileptic activity. In doing so, we will consider how the availability of experimental techniques has both advanced and restricted our ability to study these phenomena.

  17. Ion implantation technology

    CERN Document Server

    Downey, DF; Jones, KS; Ryding, G

    1993-01-01

    Ion implantation technology has made a major contribution to the dramatic advances in integrated circuit technology since the early 1970's. The ever-present need for accurate models in ion implanted species will become absolutely vital in the future due to shrinking feature sizes. Successful wide application of ion implantation, as well as exploitation of newly identified opportunities, will require the development of comprehensive implant models. The 141 papers (including 24 invited papers) in this volume address the most recent developments in this field. New structures and possible approach

  18. Phthalimides: Supramolecular Interactions in Crystals, Hypersensitive Solution 1H-NMR Dynamics and Energy Transfer to Europium(III and Terbium(III States

    Directory of Open Access Journals (Sweden)

    David J. Williams

    2003-07-01

    Full Text Available Detailed crystal structures and 1H-NMR characteristics of some alkylaminephthalimides, including dendritic polyphthalimides, are reported. These investigations were undertaken in order to obtain a better understanding of the relationship between solid-state supramolecular interactions, their persistence in solution and associated dynamics of magnetically hypersensitive phthalimide aromatic AA'BB'-AA'XX' proton NMR resonances. Some alkylamine phthalimides feature folded molecular geometries, which we attribute to n-π interactions among proximal amine-phthalimide sites; those alkylamine-phthalimides that have no possibility for such interactions feature fully extended phthalimide functionalities. Accordingly, alkylamine phthalimide compounds with folded solid-state geometries feature solvent and temperature dependent hypersensitive AA'BB'-AA'XX' 1H-NMR line profiles, which we attribute to the n-π interactions. Luminescence of Eu3+(5D0 and Tb3+(5D4 states show well defined metal ion environments in their complexes with dendritic phthalimides, as well as relatively weak phthalimide-lanthanide(III interactions.

  19. Ion exchange phenomena

    Energy Technology Data Exchange (ETDEWEB)

    Bourg, I.C.; Sposito, G.

    2011-05-01

    Ion exchange phenomena involve the population of readily exchangeable ions, the subset of adsorbed solutes that balance the intrinsic surface charge and can be readily replaced by major background electrolyte ions (Sposito, 2008). These phenomena have occupied a central place in soil chemistry research since Way (1850) first showed that potassium uptake by soils resulted in the release of an equal quantity of moles of charge of calcium and magnesium. Ion exchange phenomena are now routinely modeled in studies of soil formation (White et al., 2005), soil reclamation (Kopittke et al., 2006), soil fertilitization (Agbenin and Yakubu, 2006), colloidal dispersion/flocculation (Charlet and Tournassat, 2005), the mechanics of argillaceous media (Gajo and Loret, 2007), aquitard pore water chemistry (Tournassat et al., 2008), and groundwater (Timms and Hendry, 2007; McNab et al., 2009) and contaminant hydrology (Chatterjee et al., 2008; van Oploo et al., 2008; Serrano et al., 2009).

  20. Sensing with Ion Channels

    CERN Document Server

    Martinac, Boris

    2008-01-01

    All living cells are able to detect and translate environmental stimuli into biologically meaningful signals. Sensations of touch, hearing, sight, taste, smell or pain are essential to the survival of all living organisms. The importance of sensory input for the existence of life thus justifies the effort made to understand its molecular origins. Sensing with Ion Channels focuses on ion channels as key molecules enabling biological systems to sense and process the physical and chemical stimuli that act upon cells in their living environment. Its aim is to serve as a reference to ion channel specialists and as a source of new information to non specialists who want to learn about the structural and functional diversity of ion channels and their role in sensory physiology.

  1. Multi-Ion Magnetohydrodynamics

    Science.gov (United States)

    Toth, G.; Glocer, A.; Ma, Y.; Najib, D.; Gombosi, T.

    2010-09-01

    We derive and numerically solve the full set of magnetohydrodynamic equations with multiple ion fluids. The numerical difficulties and the algorithmic solutions are discussed. We show some preliminary results for the interaction of Mars' ionosphere with the solar wind.

  2. Ion Mass Determination

    DEFF Research Database (Denmark)

    2010-01-01

    An apparatus (100) is described for determining the mass of ions, the apparatus configured to hold a plasma (101 ) having a plasma potential. The apparatus (100) comprises an electrode (102) having a surface extending in a surface plane and an insulator (104) interfacing with the electrode (102......, and a processing unit (108) configured to interpret the detected impact locations in terms of the mass of the impacting ions....

  3. Ion exchange equilibrium constants

    CERN Document Server

    Marcus, Y

    2013-01-01

    Ion Exchange Equilibrium Constants focuses on the test-compilation of equilibrium constants for ion exchange reactions. The book first underscores the scope of the compilation, equilibrium constants, symbols used, and arrangement of the table. The manuscript then presents the table of equilibrium constants, including polystyrene sulfonate cation exchanger, polyacrylate cation exchanger, polymethacrylate cation exchanger, polysterene phosphate cation exchanger, and zirconium phosphate cation exchanger. The text highlights zirconium oxide anion exchanger, zeolite type 13Y cation exchanger, and

  4. Miniaturized Ion Mobility Spectrometer

    Science.gov (United States)

    Kaye, William J (Inventor); Stimac, Robert M. (Inventor)

    2017-01-01

    By utilizing the combination of a unique electronic ion injection control circuit in conjunction with a particularly designed drift cell construction, the instantly disclosed ion mobility spectrometer (IMS) achieves increased levels of sensitivity, while achieving significant reductions in size and weight. The instant IMS is of a much simpler and easy to manufacture design, rugged and hermetically sealed, capable of operation at high temperatures to at least 250 degrees Centigrade, and is uniquely sensitive, particularly to explosive chemicals.

  5. Numerical Simulation of Multicomponent Ion Beam from Ion Sources

    CERN Document Server

    Alexandrov, V S; Kazarinov, Yu M; Shevtsov, V P; Shirkov, G D

    1999-01-01

    A program library for numerical simulation of a multicomponent charged particle beam from ion sources is presented. The library is aimed for simulation of high current, low energy multicomponent ion beam from ion source through beamline and realized under the Windows user interface for the IBM PC. It is used for simulation and optimization of beam dynamics and based on successive and consistent application of two methods: the momentum method of distribution function (RMS technique) and particle in cell method. The library has been used to simulate and optimize the transportation of tantalum ion beam from the laser ion source (CERN) and calcium ion beam from the ECR ion source (JINR, Dubna).

  6. 2010 ion run: completed!

    CERN Multimedia

    CERN Bulletin

    2010-01-01

    After a very fast switchover from protons to lead ions, the LHC has achieved performances that allowed the machine to exceed both peak and integrated luminosity by a factor of three. Thanks to this, experiments have been able to produce high-profile results on ion physics almost immediately, confirming that the LHC was able to keep its promises for ions as well as for protons.   First direct observation of jet quenching. A seminar on 2 December was the opportunity for the ALICE, ATLAS and CMS collaborations to present their first results on ion physics in front of a packed auditorium. These results are important and are already having a major impact on the understanding of the physics processes that involve the basic constituents of matter at high energies. In the ion-ion collisions, the temperature is so high that partons (quarks and gluons), which are usually constrained inside the nucleons, are deconfined to form a highly dense and hot soup known as quark-gluon plasma (QGP). The existence of ...

  7. Radiative ion-ion neutralization: a new gas-phase atmospheric pressure ion transduction mechanism.

    Science.gov (United States)

    Davis, Eric J; Siems, William F; Hill, Herbert H

    2012-06-05

    All atmospheric pressure ion detectors, including photo ionization detectors, flame ionization detectors, electron capture detectors, and ion mobility spectrometers, utilize Faraday plate designs in which ionic charge is collected and amplified. The sensitivity of these Faraday plate ion detectors are limited by thermal (Johnson) noise in the associated electronics. Thus approximately 10(6) ions per second are required for a minimal detection. This is not the case for ion detection under vacuum conditions where secondary electron multipliers (SEMs) can be used. SEMs produce a cascade of approximately 10(6) electrons per ion impinging on the conversion dynode. Similarly, photomultiplier tubes (PMTs) can generate approximately 10(6) electrons per photon. Unlike SEMs, however, PMTs are evacuated and sealed so that they are commonly used under atmospheric pressure conditions. This paper describes an atmospheric pressure ion detector based on coupling a PMT with light emitted from ion-ion neutralization reactions. The normal Faraday plate collector electrode was replaced with an electrode "needle" used to concentrate the anions as they were drawn to the tip of the needle by a strong focusing electric field. Light was emitted near the surface of the electrode when analyte ions were neutralized with cations produced from the anode. Although radiative-ion-ion recombination has been previously reported, this is the first time ions from separate ionization sources have been combined to produce light. The light from this radiative-ion-ion-neutralization (RIIN) was detected using a photon multiplier such that an ion mobility spectrum was obtained by monitoring the light emitted from mobility separated ions. An IMS spectrum of nitroglycerin (NG) was obtained utilizing RIIN for tranducing the mobility separated ions into an analytical signal. The implications of this novel ion transduction method are the potential for counting ions at atmospheric pressure and for obtaining ion

  8. Ion-selective electrode reviews

    CERN Document Server

    Thomas, J D R

    1983-01-01

    Ion-Selective Electrode Reviews, Volume 5 is a collection of articles that covers ion-speciation. The book aims to present the advancements of the range and capabilities of selective ion-sensors. The topics covered in the selection are neutral carrier based ion-selective electrodes; reference electrodes and liquid junction effects in ion-selective electrode potentiometry; ion transfer across water/organic phase boundaries and analytical; and carbon substrate ion-selective electrodes. The text will be of great use to chemists and chemical engineers.

  9. Ion optics of RHIC EBIS

    Energy Technology Data Exchange (ETDEWEB)

    Pikin, A.; Alessi, J.; Beebe, E.; Kponou, A.; Okamura, M.; Raparia, D.; Ritter, J.; Tan, Y.; Kuznetsov, G.

    2011-09-10

    RHIC EBIS has been commissioned to operate as a versatile ion source on RHIC injection facility supplying ion species from He to Au for Booster. Except for light gaseous elements RHIC EBIS employs ion injection from several external primary ion sources. With electrostatic optics fast switching from one ion species to another can be done on a pulse to pulse mode. The design of an ion optical structure and the results of simulations for different ion species are presented. In the choice of optical elements special attention was paid to spherical aberrations for high-current space charge dominated ion beams. The combination of a gridded lens and a magnet lens in LEBT provides flexibility of optical control for a wide range of ion species to satisfy acceptance parameters of RFQ. The results of ion transmission measurements are presented.

  10. Silane Discharge Ion Chemistry.

    Science.gov (United States)

    Chatham, Robert Hood, III

    We have studied silane dc, rf and dc proximity discharges, using mass spectroscopic measurements of the positive ions as a detailed diagnostic for the type of discharge used to produce hydrogenated amorphous silicon solar photovoltaic cells. The properties and quality of these films depends in a very complex way upon the interactions of the many reactive neutral and ion species in the discharge. We have developed qualitative models of the ion chemical processes in these discharges from our measurements. Knowledge of the ion-molecule and electron-molecule collision cross sections is important to any attempt at understanding silane discharge chemistry. Consequently, we have measured the electron impact ionization cross sections for silane and disilane, and for comparison purposes also for methane and ethane. In addition, we have measured the rate coefficients for charge exchange reactions of He('+), Ne('+), and Ar('+) with silane, disilane, methane, and ethane, as these are important to understanding discharges in inert gas-silane mixtures. We have developed a detailed quantitative model of the cathode sheath region of a silane dc discharge, by extending the best recent calculation of the electron motion in the sheath to a self-consistent form which includes the ion motion. This model is used with comparison of silane dc discharge data to diagnose the ion chemistry occurring in the sheath region of silane dc discharge. The understanding of the discharge ion chemical processes that we have gained in this study represent an important step toward understanding the chemical and physical processes leading to film growth.

  11. Ion-selective electrode reviews

    CERN Document Server

    Thomas, J D R

    1985-01-01

    Ion-Selective Electrode Reviews, Volume 7 is a collection of papers that covers the applications of electrochemical sensors, along with the versatility of ion-selective electrodes. The coverage of the text includes solid contact in membrane ion-selective electrodes; immobilized enzyme probes for determining inhibitors; potentiometric titrations based on ion-pair formation; and application of ion-selective electrodes in soil science, kinetics, and kinetic analysis. The text will be of great use to chemists and chemical engineers.

  12. The ion circus

    Energy Technology Data Exchange (ETDEWEB)

    Minaya Ramirez, Enrique [GSI Helmholtzzentrum, Darmstadt (Germany); Lunney, David [CSNSM- IN2P3/CNRS, Universite de Paris-Sud, Orsay (France)

    2010-07-01

    The ability to prepare radioactive beams for experiments in nuclear structure has seen important developments in recent years. The use of ion traps and buffer-gas cooling now enables the accumulation and purification of even short-lived nuclides. This is a key point for future installations since higher intensity also brings increased isobaric contamination which can be disastrous for background. Until now, the development of beam cooler/bunchers has relied on linear (radiofrequency quadrupole) Paul traps. In this contribution we describe the progress in developing a novel circular Paul trap. The ion circus, so named for its ability to trap ions at different positions along the ring circumference and to eject them in either perpendicular or tangential direction, has also been designed to cool and mass separate the ions over a longer flight path. The resolving power is increased as the ions orbit in the ring and are cooled with buffer gas at a much lower pressure. The first prototype is now under test in Orsay. We report results of the first tests and the future program.

  13. Molecular ion photofragment spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Bustamente, S.W.

    1983-11-01

    A new molecular ion photofragment spectrometer is described which features a supersonic molecular beam ion source and a radio frequency octapole ion trap interaction region. This unique combination allows several techniques to be applied to the problem of detecting a photon absorption event of a molecular ion. In particular, it may be possible to obtain low resolution survey spectra of exotic molecular ions by using a direct vibrational predissociation process, or by using other more indirect detection methods. The use of the spectrometer is demonstrated by measuring the lifetime of the O/sub 2//sup +/(/sup 4/..pi../sub u/) metastable state which is found to consist of two main components: the /sup 4/..pi../sub 5/2/ and /sup 4/..pi../sub -1/2/ spin components having a long lifetime (approx. 129 ms) and the /sup 4/..pi../sub 3/2/ and /sup 4/..pi../sub 1/2/ spin components having a short lifetime (approx. 6 ms).

  14. Laser ion source for isobaric heavy ion collider experiment.

    Science.gov (United States)

    Kanesue, T; Kumaki, M; Ikeda, S; Okamura, M

    2016-02-01

    Heavy-ion collider experiment in isobaric system is under investigation at Relativistic Heavy Ion Collider. For this experiment, ion source is required to maximize the abundance of the intended isotope. The candidate of the experiment is (96)Ru + (96)Zr. Since the natural abundance of particular isotope is low and composition of isotope from ion source depends on the composites of the target, an isotope enriched material may be needed as a target. We studied the performance of the laser ion source required for the experiment for Zr ions.

  15. Ion-selective electrodes

    CERN Document Server

    Mikhelson, Konstantin N

    2013-01-01

    Ion-selective electrodes (ISEs) have a wide range of applications in clinical, environmental, food and pharmaceutical analysis as well as further uses in chemistry and life sciences. Based on his profound experience as a researcher in ISEs and a course instructor, the author summarizes current knowledge for advanced teaching and training purposes with a particular focus on ionophore-based ISEs. Coverage includes the basics of measuring with ISEs, essential membrane potential theory and a comprehensive overview of the various classes of ion-selective electrodes. The principles of constructing I

  16. Magnetic ions in crystals

    CERN Document Server

    Stevens, K W

    2014-01-01

    There have been many demonstrations, particularly for magnetic impurity ions in crystals, that spin-Hamiltonians are able to account for a wide range of experimental results in terms of much smaller numbers of parameters. Yet they were originally derived from crystal field theory, which contains a logical flaw; electrons on the magnetic ions are distinguished from those on the ligands. Thus there is a challenge: to replace crystal field theory with one of equal or greater predictive power that is based on a surer footing. The theory developed in this book begins with a generic Hamiltonian, on

  17. Interferometry with Strontium Ions

    Science.gov (United States)

    Jackson, Jarom; Lambert, Enoch; Otterstrom, Nils; Jones, Tyler; Durfee, Dallin

    2014-05-01

    We describe progress on a cold ion matter-wave interferometer. Cold Strontium atoms are extracted from an LVIS. The atoms will be photo-ionized with a two-photon transition to an auto-ionizing state in the continuum. The ions will be split and recombined using stimulated Raman transitions from a pair of diode lasers injection locked to two beams from a master laser which have been shifted up and down by half the hyperfine splitting. We are developing laser instrumentation for this project including a method to prevent mode-hopping by analyzing laser frequency noise, and an inexpensive, robust wavelength meter. Supported by NSF Award No. 1205736.

  18. Analytical applications of ion exchangers

    CERN Document Server

    Inczédy, J

    1966-01-01

    Analytical Applications of Ion Exchangers presents the laboratory use of ion-exchange resins. This book discusses the development in the analytical application of ion exchangers. Organized into 10 chapters, this book begins with an overview of the history and significance of ion exchangers for technical purposes. This text then describes the properties of ion exchangers, which are large molecular water-insoluble polyelectrolytes having a cross-linked structure that contains ionic groups. Other chapters consider the theories concerning the operation of ion-exchange resins and investigate th

  19. Ion-selective electrode reviews

    CERN Document Server

    Thomas, J D R

    1982-01-01

    Ion-Selective Electrode Reviews, Volume 3, provides a review of articles on ion-selective electrodes (ISEs). The volume begins with an article on methods based on titration procedures for surfactant analysis, which have been developed for discrete batch operation and for continuous AutoAnalyser use. Separate chapters deal with detection limits of ion-selective electrodes; the possibility of using inorganic ion-exchange materials as ion-sensors; and the effect of solvent on potentials of cells with ion-selective electrodes. Also included is a chapter on advances in calibration procedures, the d

  20. Ion-dust streaming instability with non-Maxwellian ions

    Energy Technology Data Exchange (ETDEWEB)

    Kählert, Hanno, E-mail: kaehlert@theo-physik.uni-kiel.de [Institut für Theoretische Physik und Astrophysik, Christian-Albrechts-Universität zu Kiel, Leibnizstr. 15, 24098 Kiel (Germany)

    2015-07-15

    The influence of non-Maxwellian ions on the ion-dust streaming instability in a complex plasma is investigated. The ion susceptibility employed for the calculations self-consistently accounts for the acceleration of the ions by a homogeneous background electric field and their collisions with neutral gas particles via a Bhatnagar-Gross-Krook collision term [e.g., A. V. Ivlev et al., Phys. Rev. E 71, 016405 (2005)], leading to significant deviations from a shifted Maxwellian distribution. The dispersion relation and the properties of the most unstable mode are studied in detail and compared with the Maxwellian case. The largest deviations occur at low to intermediate ion-neutral damping. In particular, the growth rate of the instability for ion streaming below the Bohm speed is found to be lower than in the case of Maxwellian ions, yet remains on a significant level even for fast ion flows above the Bohm speed.

  1. Quadrupole Ion Traps

    Indian Academy of Sciences (India)

    ), while in the Paul trap a RF potential is applied to the electrodes (Figure 4b). The Penning Trap. It is now clear that, the dc field provides confinement of the ions along the axial direction while there is a repulsive force in the .... _--.-----. Zo. Lr. o.

  2. Lithium ion conducting electrolytes

    Science.gov (United States)

    Angell, Charles Austen; Liu, Changle; Xu, Kang; Skotheim, Terje A.

    1999-01-01

    The present invention relates generally to highly conductive alkali-metal ion non-crystalline electrolyte systems, and more particularly to novel and unique molten (liquid), rubbery, and solid electrolyte systems which are especially well suited for use with high current density electrolytic cells such as primary and secondary batteries.

  3. Lithium ion conducting electrolytes

    Energy Technology Data Exchange (ETDEWEB)

    Angell, C.A.; Liu, C.; Xu, K.; Skotheim, T.A.

    1999-10-05

    The present invention relates generally to highly conductive alkali-metal ion non-crystalline electrolyte systems, and more particularly to novel and unique molten (liquid), rubbery, and solid electrolyte systems which are especially well suited for use with high current density electrolytic cells such as primary and secondary batteries.

  4. Anodes sliced with ions

    NARCIS (Netherlands)

    Boukamp, Bernard A.

    2006-01-01

    A detailed image of a complex fuel-cell anode structure, obtained through ion-beam milling, SEM imaging and advanced digital reconstruction, yields an accurate description of the three-dimensional structure, and enables correct prediction of the electrode's properties

  5. Polyatomic ions from a high current ion implanter driven by a liquid metal ion source.

    Science.gov (United States)

    Pilz, W; Laufer, P; Tajmar, M; Böttger, R; Bischoff, L

    2017-12-01

    High current liquid metal ion sources are well known and found their first application as field emission electric propulsion thrusters in space technology. The aim of this work is the adaption of such kind of sources in broad ion beam technology. Surface patterning based on self-organized nano-structures on, e.g., semiconductor materials formed by heavy mono- or polyatomic ion irradiation from liquid metal (alloy) ion sources (LMAISs) is a very promising technique. LMAISs are nearly the only type of sources delivering polyatomic ions from about half of the periodic table elements. To overcome the lack of only very small treated areas by applying a focused ion beam equipped with such sources, the technology taken from space propulsion systems was transferred into a large single-end ion implanter. The main component is an ion beam injector based on high current LMAISs combined with suited ion optics allocating ion currents in the μA range in a nearly parallel beam of a few mm in diameter. Different types of LMAIS (needle, porous emitter, and capillary) are presented and characterized. The ion beam injector design is specified as well as the implementation of this module into a 200 kV high current ion implanter operating at the HZDR Ion Beam Center. Finally, the obtained results of large area surface modification of Ge using polyatomic Bi 2 + ions at room temperature from a GaBi capillary LMAIS will be presented and discussed.

  6. Ion transport from plasma ion source at ISOLTRAP

    CERN Document Server

    Steinsberger, Timo Pascal

    2017-01-01

    In this report, my work as CERN Summer Student at the ISOLTRAP experiment at ISOLDE is described. A new plasma ion source used as oine source for calibration and implemented before my arrival was commissioned and transportation settings for the produced ions to the ion traps were found. The cyclotron frequencies of 40Ar and the xenon isotopes 129-132Xe were measured using time-of-flight and phase-imaging ion-cyclotron-resonance mass spectroscopy.

  7. Ion-Beam-Excited Electrostatic Ion Cyclotron Waves

    DEFF Research Database (Denmark)

    Michelsen, Poul; Pécseli, Hans; Juul Rasmussen, Jens

    1976-01-01

    Self-excited electrostatic ion cyclotron waves were observed in an ion-beam-plasma system produced in a DP-operated Q-machine. The frequency of the waves showed the theoretically predicted variation with the magnetic field.......Self-excited electrostatic ion cyclotron waves were observed in an ion-beam-plasma system produced in a DP-operated Q-machine. The frequency of the waves showed the theoretically predicted variation with the magnetic field....

  8. ECR ion source based low energy ion beam facility

    Indian Academy of Sciences (India)

    Mass analyzed highly charged ion beams of energy ranging from a few keV to a few MeV plays an important role in various aspects of research in modern physics. In this paper a unique low energy ion beam facility (LEIBF) set up at Nuclear Science Centre (NSC) for providing low and medium energy multiply charged ion ...

  9. Unstable Electrostatic Ion Cyclotron Waves Exited by an Ion Beam

    DEFF Research Database (Denmark)

    Michelsen, Poul; Pécseli, Hans; Juul Rasmussen, Jens

    1976-01-01

    Electrostatic ion cyclotron waves were observed in a quiescent cesium plasma into which a low‐energy beam of sodium ions was injected. The instability appeared when the beam velocity was above 12 times the ion thermal velocity. The waves propagated along the magnetic field with a velocity somewhat...

  10. Using Ion Exchange Chromatography to Separate and Quantify Complex Ions

    Science.gov (United States)

    Johnson, Brian J.

    2014-01-01

    Ion exchange chromatography is an important technique in the separation of charged species, particularly in biological, inorganic, and environmental samples. In this experiment, students are supplied with a mixture of two substitution-inert complex ions. They separate the complexes by ion exchange chromatography using a "flash"…

  11. Prolonging coherence in trapped ions

    CSIR Research Space (South Africa)

    Uys, H

    2010-09-01

    Full Text Available The authors study pulse sequences that dynamically decouple 9Be+ ions from their decohering environment. The noise environment the ions see is artificially synthesized to emulate a variety of physical systems. By incorporating measurement feedback...

  12. Membranes in Lithium Ion Batteries

    Directory of Open Access Journals (Sweden)

    Junbo Hou

    2012-07-01

    Full Text Available Lithium ion batteries have proven themselves the main choice of power sources for portable electronics. Besides consumer electronics, lithium ion batteries are also growing in popularity for military, electric vehicle, and aerospace applications. The present review attempts to summarize the knowledge about some selected membranes in lithium ion batteries. Based on the type of electrolyte used, literature concerning ceramic-glass and polymer solid ion conductors, microporous filter type separators and polymer gel based membranes is reviewed.

  13. Membranes in Lithium Ion Batteries

    Science.gov (United States)

    Yang, Min; Hou, Junbo

    2012-01-01

    Lithium ion batteries have proven themselves the main choice of power sources for portable electronics. Besides consumer electronics, lithium ion batteries are also growing in popularity for military, electric vehicle, and aerospace applications. The present review attempts to summarize the knowledge about some selected membranes in lithium ion batteries. Based on the type of electrolyte used, literature concerning ceramic-glass and polymer solid ion conductors, microporous filter type separators and polymer gel based membranes is reviewed. PMID:24958286

  14. The Ion Conveyor. An ion focusing and conveying device.

    Science.gov (United States)

    Colburn, Alex W; Giannakopulos, A E; Derrick, Peter J

    2004-01-01

    The control and transmission of ions or small charged droplets in the intermediate to high-pressure regime is of primary importance in areas such as atmospheric pressure ionisation. Where small apertures separate differentially pumped vacuum regions in the inlet systems to mass spectrometers, a large proportion of the available ion current is lost to the surrounding electrode structures. A new ion-optical device, named the ion conveyor, incorporating electrodynamic focusing and conveying of charged entities is described. Results from ion-optical simulations are presented demonstrating the performance of the device in various operating modes and electrode configurations.

  15. Ion Accelerator Merges Several Beams

    Science.gov (United States)

    Aston, G.

    1984-01-01

    Intense ion beam formed by merging multiple ion beamlets into one concentrated beam. Beamlet holes in graphite screen and focusing grids arranged in hexagonal pattern. Merged beam passes through single hole in each of aluminum accelerator and decelerator grids. Ion extraction efficiency, beam intensity, and focusing improved.

  16. Scanning ion microscopy with low energy lithium ions

    Energy Technology Data Exchange (ETDEWEB)

    Twedt, Kevin A. [Center for Nanoscale Science and Technology, National Institute of Standards and Technology, Gaithersburg, MD 20899 (United States); Maryland NanoCenter, University of Maryland, College Park, MD 20742 (United States); Chen, Lei [Center for Nanoscale Science and Technology, National Institute of Standards and Technology, Gaithersburg, MD 20899 (United States); McClelland, Jabez J., E-mail: jabez.mcclelland@nist.gov [Center for Nanoscale Science and Technology, National Institute of Standards and Technology, Gaithersburg, MD 20899 (United States)

    2014-07-01

    Using an ion source based on photoionization of laser-cooled lithium atoms, we have developed a scanning ion microscope with probe sizes of a few tens of nanometers and beam energies from 500 eV to 5 keV. These beam energies are much lower than the typical operating energies of the helium ion microscope or gallium focused ion beam systems. We demonstrate how low energy can be advantageous in ion microscopy when detecting backscattered ions, due to a decreased interaction volume and the potential for surface sensitive composition analysis. As an example application that demonstrates these advantages, we non-destructively image the removal of a thin residual resist layer during plasma etching in a nano-imprint lithography process. - Highlights: • We use an ion source based on photoionization of laser-cooled lithium atoms. • The ion source makes possible a low energy (500 eV to 5 keV) scanning ion microscope. • Low energy is preferred for ion microscopy with backscattered ions. • We use the microscope to image a thin resist used in nano-imprint lithography.

  17. Ion bipolar junction transistors.

    Science.gov (United States)

    Tybrandt, Klas; Larsson, Karin C; Richter-Dahlfors, Agneta; Berggren, Magnus

    2010-06-01

    Dynamic control of chemical microenvironments is essential for continued development in numerous fields of life sciences. Such control could be achieved with active chemical circuits for delivery of ions and biomolecules. As the basis for such circuitry, we report a solid-state ion bipolar junction transistor (IBJT) based on conducting polymers and thin films of anion- and cation-selective membranes. The IBJT is the ionic analogue to the conventional semiconductor BJT and is manufactured using standard microfabrication techniques. Transistor characteristics along with a model describing the principle of operation, in which an anionic base current amplifies a cationic collector current, are presented. By employing the IBJT as a bioelectronic circuit element for delivery of the neurotransmitter acetylcholine, its efficacy in modulating neuronal cell signaling is demonstrated.

  18. Trapped Ion Qubits

    Energy Technology Data Exchange (ETDEWEB)

    Maunz, Peter Lukas Wilhelm

    2017-04-01

    Qubits can be encoded in clock states of trapped ions. These states are well isolated from the environment resulting in long coherence times [1] while enabling efficient high-fidelity qubit interactions mediated by the Coulomb coupled motion of the ions in the trap. Quantum states can be prepared with high fidelity and measured efficiently using fluorescence detection. State preparation and detection with 99.93% fidelity have been realized in multiple systems [1,2]. Single qubit gates have been demonstrated below rigorous fault-tolerance thresholds [1,3]. Two qubit gates have been realized with more than 99.9% fidelity [4,5]. Quantum algorithms have been demonstrated on systems of 5 to 15 qubits [6–8].

  19. Improving Ion Computed Tomography

    DEFF Research Database (Denmark)

    Hansen, David Christoffer

    2014-01-01

    -HIT, og de blev tilpasset eksperimentelle tværsnit. Modellerne passede godt med eksperimentelle målinger af kernefragmentation af kulstof i vand, hvorimod der var større afvigelser for neon. I tidligere undersøgelser af ion CT med ioner tungere end brint har dosis altid været meget høj, i flere tilfælde...

  20. Ion funnel device

    Energy Technology Data Exchange (ETDEWEB)

    Ibrahim, Yehia M.; Chen, Tsung-Chi; Harrer, Marques B.; Tang, Keqi; Smith, Richard D.

    2017-11-21

    An ion funnel device is disclosed. A first pair of electrodes is positioned in a first direction. A second pair of electrodes is positioned in a second direction. The device includes an RF voltage source and a DC voltage source. A RF voltage with a superimposed DC voltage gradient is applied to the first pair of electrodes, and a DC voltage gradient is applied to the second pair of electrodes.

  1. Ion Acoustic Microscopy

    Science.gov (United States)

    1985-07-01

    Murphy and L. C. Aamodt , "Signal Enhancement in Photothermal Imaging Produced by Three Dimensional Heat Flow", Appl. Phys. Lett. 39, 519 (1981); L. C... Aamodt and J. C. Murphy, "Photothermal Measurements Using a Localized Excitation Source", J. Appl. Phys. 52, 4903 (1981) (9) R. L. Thomas, L. D. Favro...25 (23) J. C. Murphy, F. G. Satkiewicz and L. C. Aamodt , "Ion Acoustic Imaging of Buried Flaws in Aluminum", Review of Progress in Quantitative NDE

  2. Micro Ion Frequency Standard

    Science.gov (United States)

    2009-11-01

    Figure 6. (a) Fabricated VCSEL . (b) Emission spectrum of VCSEL at 1 mA drive current . As expected, our initial VCSEL wafers produced much less...light source at 369 nm. (a) (b) Figure 7. (a) 740-nm VCSEL output power and voltage versus current . (b) Periodically poled KTP crystal with...micro ion frequency standard and relevant current results. INTRODUCTION Vapor cell atomic clocks have seen extreme miniaturization within the past

  3. Superheated Water Ion-exchange Chromatography

    National Research Council Canada - National Science Library

    SHIBUKAWA, Masami; MORINAGA, Ryota; SAITO, Shingo

    2016-01-01

    ... superheated water chromatography. The selectivity coefficient for a pair of identically charged inorganic ions, such as alkali metal ions and halide ions, approaches unity as the temperature increases, provided that the ions...

  4. Ion channeling revisited

    Energy Technology Data Exchange (ETDEWEB)

    Doyle, Barney Lee [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Corona, Aldo [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Nguyen, Anh [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2014-09-01

    A MS Excel program has been written that calculates accidental, or unintentional, ion channeling in cubic bcc, fcc and diamond lattice crystals or polycrystalline materials. This becomes an important issue when simulating the creation by energetic neutrons of point displacement damage and extended defects using beams of ions. All of the tables and graphs in the three Ion Beam Analysis Handbooks that previously had to be manually looked up and read from were programed into Excel in handy lookup tables, or parameterized, for the case of the graphs, using rather simple exponential functions with different powers of the argument. The program then offers an extremely convenient way to calculate axial and planar half-angles and minimum yield or dechanneling probabilities, effects on half-angles of amorphous overlayers, accidental channeling probabilities for randomly oriented crystals or crystallites, and finally a way to automatically generate stereographic projections of axial and planar channeling half-angles. The program can generate these projections and calculate these probabilities for axes and [hkl] planes up to (555).

  5. Novel laser ion sources

    CERN Document Server

    Fournier, P; Kugler, H; Lisi, N; Scrivens, R; Rodríguez, F V; Düsterer, S; Sauerbrey, R; Schillinger, H; Theobald, W; Veisz, L; Tisch, J W G; Smith, R A

    2000-01-01

    Development in the field of high-power laser systems with repetition rates of several Hz and energies of few joules is highly active and opening, giving new possibilities for the design of laser ions sources. Preliminary investigations on the use of four different laser and target configurations are presented: (1) A small CO/sub 2/ laser (100 mJ, 10.6 mu m) focused onto a polyethylene target to produce C ions at 1 Hz repetition rate (CERN). (2) An excimer XeCl laser (6 J, 308 nm) focused onto solid targets (Frascati). (3) A femtosecond Ti: sapphire laser (250 mJ, 800 nm) directed onto a solid targets (Jena). (4) A picosecond Nd: yttrium-aluminum-garnet (0.3 J, 532 nm) focused into a dense medium of atomic clusters and onto solid targets (London). The preliminary experimental results and the most promising schemes will be discussed with respect to the scaling of the production of high numbers of highly charged ions. Different lasers are compared in terms of current density at 1 m distance for each charge state...

  6. Resonance Ionization Laser Ion Sources

    CERN Document Server

    Marsh, B

    2013-01-01

    The application of the technique of laser resonance ionization to the production of singly charged ions at radioactive ion beam facilities is discussed. The ability to combine high efficiency and element selectivity makes a resonance ionization laser ion source (RILIS) an important component of many radioactive ion beam facilities. At CERN, for example, the RILIS is the most commonly used ion source of the ISOLDE facility, with a yearly operating time of up to 3000 hours. For some isotopes the RILIS can also be used as a fast and sensitive laser spectroscopy tool, provided that the spectral resolution is sufficiently high to reveal the influence of nuclear structure on the atomic spectra. This enables the study of nuclear properties of isotopes with production rates even lower than one ion per second and, in some cases, enables isomer selective ionization. The solutions available for the implementation of resonance laser ionization at radioactive ion beam facilities are summarized. Aspects such as the laser r...

  7. Electron string ion sources for carbon ion cancer therapy accelerators

    Science.gov (United States)

    Boytsov, A. Yu.; Donets, D. E.; Donets, E. D.; Donets, E. E.; Katagiri, K.; Noda, K.; Ponkin, D. O.; Ramzdorf, A. Yu.; Salnikov, V. V.; Shutov, V. B.

    2015-08-01

    The type of the Electron String Ion Sources (ESIS) is considered to be the appropriate one to produce pulsed C4+ and C6+ ion beams for cancer therapy accelerators. In fact, the new test ESIS Krion-6T already now provides more than 1010 C4+ ions per pulse and about 5 × 109 C6+ ions per pulse. Such ion sources could be suitable to apply at synchrotrons. It has also been found that Krion-6T can provide more than 1011 C6+ ions per second at the 100 Hz repetition rate, and the repetition rate can be increased at the same or larger ion output per second. This makes ESIS applicable at cyclotrons as well. ESIS can be also a suitable type of ion source to produce the 11C radioactive ion beams. A specialized cryogenic cell was experimentally tested at the Krion-2M ESIS for pulse injection of gaseous species into the electron string. It has been shown in experiments with stable methane that the total conversion efficiency of methane molecules to C4+ ions reached 5%÷10%. For cancer therapy with simultaneous irradiation and precise dose control (positron emission tomography) by means of 11C, transporting to the tumor with the primary accelerated 11C4+ beam, this efficiency is preliminarily considered to be large enough to produce the 11C4+ beam from radioactive methane and to inject this beam into synchrotrons.

  8. STATUS OF ITEP DECABORANE ION SOURCE PROGRAM.

    Energy Technology Data Exchange (ETDEWEB)

    KULEVOY,T.V.; PETRENKO, S.V.; KUIBEDA, R.P.; SELEZNEV, D.N.; KOZLOV, A.V.; STASEVICH, YU.B.; SITNIKOV, A.L.; SHAMAILOV, I.M.; PERSHIN, V.I.; HERSHCOVITCH, A.; JOHNSON, B.M.; GUSHENETS, V.I.; OKS, E.M.; POOLE, H.J.; MASUNOV, E.S.; POLOZOV, S.M.

    2007-08-26

    The joint research and development program is continued to develop steady-state ion source of decaborane beam for ion implantation industry. Both Freeman and Bemas ion sources for decaborane ion beam generation were investigated. Decaborane negative ion beam as well as positive ion beam were generated and delivered to the output of mass separator. Experimental results obtained in ITEP are presented.

  9. An ion trap-ion mobility-time of flight mass spectrometer with three ion sources for ion/ion reactions.

    Science.gov (United States)

    Zhao, Qin; Soyk, Matthew W; Schieffer, Gregg M; Fuhrer, Katrin; Gonin, Marc M; Houk, R S; Badman, Ethan R

    2009-08-01

    This instrument combines the capabilities of ion/ion reactions with ion mobility (IM) and time-of-flight (TOF) measurements for conformation studies and top-down analysis of large biomolecules. Ubiquitin ions from either of two electrospray ionization (ESI) sources are stored in a three dimensional (3D) ion trap (IT) and reacted with negative ions from atmospheric sampling glow discharge ionization (ASGDI). The proton transfer reaction products are then separated by IM and analyzed via a TOF mass analyzer. In this way, ubiquitin +7 ions are converted to lower charge states down to +1; the ions in lower charge states tend to be in compact conformations with cross sections down to approximately 880 A(2). The duration and magnitude of the ion ejection pulse on the IT exit and the entrance voltage on the IM drift tube can affect the measured distribution of conformers for ubiquitin +7 and +6. Alternatively, protein ions are fragmented by collision-induced dissociation (CID) in the IT, followed by ion/ion reactions to reduce the charge states of the CID product ions, thus simplifying assignment of charge states and fragments using the mobility-resolved tandem mass spectrum. Instrument characteristics and the use of a new ion trap controller and software modifications to control the entire instrument are described.

  10. Heterometallic trinuclear {CoLn(III)} (Ln = Gd, Tb, Ho and Er) complexes in a bent geometry. Field-induced single-ion magnetic behavior of the Er(III) and Tb(III) analogues.

    Science.gov (United States)

    Goura, Joydeb; Brambleby, Jamie; Topping, Craig V; Goddard, Paul A; Suriya Narayanan, Ramakirushnan; Bar, Arun Kumar; Chandrasekhar, Vadapalli

    2016-05-31

    Through the use of a multi-site compartmental ligand, 2-methoxy-6-[{2-(2-hydroxyethylamino)ethylimino}methyl]phenol (LH3), the family of heterometallic, trinuclear complexes of the formula [CoLn(L)2(μ-O2CCH3)2(H2O)3]·NO3·xMeOH·yH2O has been expanded beyond Ln = Dy(III) to include Gd(III) (), Tb(III) (), Ho(III) () and Er(III) () for , and (x = 1; y = 1) and for (x = 0; y = 2). The metallic core of these complexes consists of a (Co(III)-Ln(III)-Co(III)) motif bridged in a bent geometry resulting in six-coordinated distorted Co(III) octahedra and nine-coordinated Ln(III) monocapped square-antiprisms. The magnetic characterization of these compounds reveals the erbium and terbium analogues to display a field induced single-ion magnetic behavior similar to the dysprosium analogue but at lower temperatures. The energy barrier for the reversal of the magnetization of the CoTb(III) analogue is Ueff ≥ 15.6(4) K, while for the CoEr(III) analogue Ueff ≥ 9.9(8) K. The magnetic properties are discussed in terms of distortions of the 4f electron cloud.

  11. Electromagnetic ion/ion cyclotron instability - Theory and simulations

    Science.gov (United States)

    Winske, D.; Omidi, N.

    1992-01-01

    Linear theory and 1D and 2D hybrid simulations are employed to study electromagnetic ion/ion cyclotron (EMIIC) instability driven by the relative streaming of two field-aligned ion beams. The characteristics of the instability are studied as a function of beam density, propagation angle, electron-ion temperature ratios, and ion beta. When the propagation angle is near 90 deg the EMIIC instability has the characteristics of an electrostatic instability, while at smaller angles electromagnetic effects play a significant role as does strong beam coupling. The 2D simulations point to a narrowing of the wave spectrum and accompanying coherent effects during the linear growth stage of development. The EMIIC instability is an important effect where ion beta is low such as in the plasma-sheet boundary layer and upstream of slow shocks in the magnetotail.

  12. Ion-water clusters, bulk medium effects, and ion hydration

    CERN Document Server

    Merchant, Safir; Dean, Kelsey R; Asthagiri, D

    2011-01-01

    Thermochemistry of gas-phase ion-water clusters together with estimates of the hydration free energy of the clusters and the water ligands are used to calculate the hydration free energy of the ion. Often the hydration calculations use a continuum model of the solvent. The primitive quasichemical approximation to the quasichemical theory provides a transparent framework to anchor such efforts. Here we evaluate the approximations inherent in the primitive quasichemical approach and elucidate the different roles of the bulk medium. We find that the bulk medium can stabilize configurations of the cluster that are usually not observed in the gas phase, while also simultaneously lowering the excess chemical potential of the ion. This effect is more pronounced for soft ions. Since the coordination number that minimizes the excess chemical potential of the ion is identified as the optimal or most probable coordination number, for such soft ions, the optimum cluster size and the hydration thermodynamics obtained with...

  13. Charge Breeding of Radioactive Ions

    CERN Document Server

    Wenander, F J C

    2013-01-01

    Charge breeding is a technique to increase the charge state of ions, in many cases radioactive ions. The singly charged radioactive ions, produced in an isotope separator on-line facility, and extracted with a low kinetic energy of some tens of keV, are injected into a charge breeder, where the charge state is increased to Q. The transformed ions are either directed towards a dedicated experiment requiring highly charged ions, or post-accelerated to higher beam energies. In this paper the physics processes involved in the production of highly charged ions will be introduced, and the injection and extraction beam parameters of the charge breeder defined. A description of the three main charge-breeding methods is given, namely: electron stripping in gas jet or foil; external ion injection into an electron-beam ion source/trap (EBIS/T); and external ion injection into an electron cyclotron resonance ion source (ECRIS). In addition, some preparatory devices for charge breeding and practical beam delivery aspects ...

  14. Cobalt alloy ion sources for focused ion beam implantation

    Energy Technology Data Exchange (ETDEWEB)

    Muehle, R.; Doebeli, M. [Paul Scherrer Inst. (PSI), Villigen (Switzerland); Zimmermann, P. [Eidgenoessische Technische Hochschule, Zurich (Switzerland)

    1997-09-01

    Cobalt alloy ion sources have been developed for silicide formation by focused ion beam implantation. Four eutectic alloys AuCo, CoGe, CoY and AuCoGe were produced by electron beam welding. The AuCo liquid alloy ion source was investigated in detail. We have measured the emission current stability, the current-voltage characteristics, and the mass spectrum as a function of the mission current. (author) 1 fig., 2 refs.

  15. Spectroscopic analysis of lithium terbium tetrafluoride

    DEFF Research Database (Denmark)

    Christensen, H.P.

    1978-01-01

    . The rare-earth site in LiTbF4 possesses S4 symmetry, which allows six crystal-field parameters. ζ and the six Bim were varied to obtain the best agreement with the experimentally observed levels. Keeping F2=434 cm-1 fixed, a fit with a standard deviation of 12 cm-1 was obtained at 10 K with the following...... were calculated by diagonalizing an effective spin-orbit and crystal-field Hamiltonian in an LS basis. H=Σλi(L→·S→)i+ΣαiΣBimOim, where the parameters λi are functions of the spin-orbit parameter ζ and the Slater parameter F2. The Oim and αi are Racah operators and reduced matrix elements, respectively...

  16. Inelastic critical scattering of neutrons from terbium

    DEFF Research Database (Denmark)

    Als-Nielsen, Jens Aage; Dietrich, O.W.; Marshall, W.

    1967-01-01

    We have measured the inelasticity of the critical neutron scattering in Tb above the Néel temperature. The results show that dynamical slowing down of fluctuations does occur at a second order phase transition.......We have measured the inelasticity of the critical neutron scattering in Tb above the Néel temperature. The results show that dynamical slowing down of fluctuations does occur at a second order phase transition....

  17. Carbon Ion Therapy

    DEFF Research Database (Denmark)

    Bassler, Niels; Hansen, David Christoffer; Herrmann, Rochus

    On the importance of choice of target size for selective boosting of hypoxic tumor subvolumina in carbon ion therapy Purpose: Functional imaging methods in radiotherapy are maturing and can to some extent uncover radio resistant structures found within a tumour entity. Selective boost of identified...... hypoxic subvolumina with high-LET radiation may in principle lead to increased tumour control due to LET-dependence of the oxygen enhancement ratio (OER). Here, we demonstrate the importance of minimizing field sizes in order not to dilute the dose average LET by quantifying the OER as a function of PTV...

  18. Ion/neutral, ion/electron, ion/photon, and ion/ion interactions in tandem mass spectrometry: do we need them all? Are they enough?

    Science.gov (United States)

    McLuckey, Scott A; Mentinova, Marija

    2011-01-01

    A range of strategies and tools have been developed to facilitate the determination of primary structures of analyte molecules of interest via tandem mass spectrometry (MS/MS). The two main factors that determine the primary structural information present in an MS/MS spectrum are the type of ion generated from the analyte molecule and the dissociation method. The ion type subjected to dissociation is determined by the ionization method/conditions and ion transformation processes that might take place after initial gas-phase ion formation. Furthermore, the range of analyte-related ion types can be expanded via derivatization reactions prior to mass spectrometry. Dissociation methods include those that simply alter the population of internal states of the mass-selected ion (i.e., activation methods like collision-induced dissociation) as well as processes that rely on the transformation of the ion type prior to dissociation (e.g., electron capture dissociation). A variety of ion interactions have been studied for the purpose of ion dissociation and ion transformation, including ion/neutral, ion/photon, ion/electron, and ion/ion interactions. A wide range of phenomena have been observed, many of which have been explored/developed as means for structural analysis. The techniques arising from these phenomena are discussed within the context of the elements of structural determination in tandem mass spectrometry: ion-type definition and dissociation. Unique aspects of the various ion interactions are emphasized along with any barriers to widespread implementation. © American Society for Mass Spectrometry, 2011

  19. A novel planar ion funnel design for miniature ion optics.

    Science.gov (United States)

    Chaudhary, A; van Amerom, Friso H W; Short, R T

    2014-10-01

    The novel planar ion funnel (PIF) design presented in this article emphasizes simple fabrication, assembly, and operation, making it amenable to extreme miniaturization. Simulations performed in SIMION 8.0 indicate that ion focusing can be achieved by using a gradient of electrostatic potentials on concentric metal rings in a plane. A prototype was fabricated on a 35 × 35 mm custom-designed printed circuit board (PCB) with a center hole for ions to pass through and a series of concentric circular metal rings of increasing diameter on the front side of the PCB. Metal vias on the PCB electrically connected each metal ring to a resistive potential divider that was soldered on the back of the PCB. The PIF was tested at 5.5 × 10(-6) Torr in a vacuum test setup that was equipped with a broad-beam ion source on the front and a micro channel plate (MCP) ion detector on the back of the PIF. The ion current recorded on the MCP anode during testing indicated a 23× increase in the ion transmission through the PIF when electric potentials were applied to the rings. These preliminary results demonstrate the functionality of a 2D ion funnel design with a much smaller footprint and simpler driving electronics than conventional 3D ion funnels. Future directions to improve the design and a possible micromachining approach to fabrication are discussed in the conclusions.

  20. Enhanced life ion source for germanium and carbon ion implantation

    Energy Technology Data Exchange (ETDEWEB)

    Hsieh, Tseh-Jen; Colvin, Neil; Kondratenko, Serguei [Axcelis Technologies, Inc. 108 Cherry Hill Drive, Beverly, MA 01915 (United States)

    2012-11-06

    Germanium and carbon ions represent a significant portion of total ion implantation steps in the process flow. Very often ion source materials that used to produce ions are chemically aggressive, especially at higher temperatures, and result in fast ion source performance degradation and a very limited lifetime [B.S. Freer, et. al., 2002 14th Intl. Conf. on Ion Implantation Technology Proc, IEEE Conf. Proc., p. 420 (2003)]. GeF{sub 4} and CO{sub 2} are commonly used to generate germanium and carbon beams. In the case of GeF{sub 4} controlling the tungsten deposition due to the de-composition of WF{sub 6} (halogen cycle) is critical to ion source life. With CO{sub 2}, the materials oxidation and carbon deposition must be controlled as both will affect cathode thermionic emission and anti-cathode (repeller) efficiencies due to the formation of volatile metal oxides. The improved ion source design Extended Life Source 3 (Eterna ELS3) together with its proprietary co-gas material implementation has demonstrated >300 hours of stable continuous operation when using carbon and germanium ion beams. Optimizing cogas chemistries retard the cathode erosion rate for germanium and carbon minimizes the adverse effects of oxygen when reducing gas is introduced for carbon. The proprietary combination of hardware and co-gas has improved source stability and the results of the hardware and co-gas development are discussed.

  1. Practical aspects of trapped ion mass spectrometry, 5 applications of ion trapping devices

    CERN Document Server

    March, Raymond E

    2009-01-01

    Examines ion/neutral and ion/ion reactions, ion spectroscopy, and the structural characterization of proteins and peptides using quadropole ion trap mass spectrometry, Fourier transform - ion cyclotron resonance (FT-ICR) mass spectrometry, and traveling wave ion mobility mass spectrometry.

  2. Proton and carbon ion therapy

    CERN Document Server

    Lomax, Tony

    2013-01-01

    Proton and Carbon Ion Therapy is an up-to-date guide to using proton and carbon ion therapy in modern cancer treatment. The book covers the physics and radiobiology basics of proton and ion beams, dosimetry methods and radiation measurements, and treatment delivery systems. It gives practical guidance on patient setup, target localization, and treatment planning for clinical proton and carbon ion therapy. The text also offers detailed reports on the treatment of pediatric cancers, lymphomas, and various other cancers. After an overview, the book focuses on the fundamental aspects of proton and carbon ion therapy equipment, including accelerators, gantries, and delivery systems. It then discusses dosimetry, biology, imaging, and treatment planning basics and provides clinical guidelines on the use of proton and carbon ion therapy for the treatment of specific cancers. Suitable for anyone involved with medical physics and radiation therapy, this book offers a balanced and critical assessment of state-of-the-art...

  3. TOPICAL REVIEW: Highly charged ions

    Science.gov (United States)

    Gillaspy, J. D.

    2001-10-01

    This paper reviews some of the fundamental properties of highly charged ions, the methods of producing them (with particular emphasis on table-top devices), and their use as a tool for both basic science and applied technology. Topics discussed include: charge dependence and scaling laws along isoelectronic or isonuclear sequences (for wavefunction size or Bohr radius, ionization energy, dipole transition energy, relativistic fine structure, hyperfine structure, Zeeman effect, Stark effect, line intensities, linewidths, strength of parity violation, etc), changes in angular momentum coupling schemes, selection rules, interactions with surfaces, electron-impact ionization, the electron beam ion trap (EBIT), ion accelerators, atomic reference data, cosmic chronometers, laboratory x-ray astrophysics, vacuum polarization, solar flares, ion implantation, ion lithography, ion microprobes (SIMS and x-ray microscope), nuclear fusion diagnostics, nanotechnology, quantum computing, cancer therapy and biotechnology.

  4. An ion displacement membrame model.

    Science.gov (United States)

    Hladky, S B; Harris, J D

    1967-09-01

    The usual assumption in treating the diffusion of ions in an electric field has been that the movement of each ion is independent of the movement of the others. The resulting equation for diffusion by a succession of spontaneous jumps has been well stated by Parlin and Eyring. This paper will consider one simple case in which a different assumption is reasonable. Diffusion of monovalent positive ions is considered as a series of jumps from one fixed negative site to another. The sites are assumed to be full (electrical neutrality). Interaction occurs by the displacement of one ion by another. An ion leaves a site if and only if another ion, not necessarily of the same species, attempts to occupy the same site. Flux ratios and net fluxes are given as functions of the electrical potential, concentration ratios, and number of sites encountered in crossing the membrane. Quantitative comparisons with observations of Hodgkin and Keynes are presented.

  5. SUERC AMS ion detection

    Science.gov (United States)

    Maden, C.; Anastasi, P. A. F.; Dougans, A.; Freeman, S. P. H. T.; Kitchen, R.; Klody, G.; Schnabel, C.; Sundquist, M.; Vanner, K.; Xu, S.

    2007-06-01

    In a short time Be, C, Al, Cl, Ca and I accelerator mass spectrometry (AMS) have been established on the National Electrostatics Corporation (NEC) 5 MV pelletron system at the Scottish Universities Environmental Research Centre (SUERC). While summarising the present performance of the system, this report will focus on the details of ion detection, which sample materials are used and the analytical procedures employed for each individual species during routine analysis. All rare isotope detection is with a single flexible detector and ion event analysis system, but switching of analysed species typically requires a detector reconfiguration. Configurations for routine 10Be, 14C, 26Al, 36Cl, 41Ca and 129I detection have been established and will be presented here. Notably, there has proven to be sufficient suppression of the isobaric interferences of 36Cl and 41Ca in the 5+ charge state using an argon gas stripper at a terminal voltage of 5.0 MV to allow for routine analysis of these isotopes.

  6. Electrically switched ion exchange

    Energy Technology Data Exchange (ETDEWEB)

    Lilga, M.A. [Pacific Northwest National Lab., Richland, WA (United States); Schwartz, D.T.; Genders, D.

    1997-10-01

    A variety of waste types containing radioactive {sup 137}Cs are found throughout the DOE complex. These waste types include water in reactor cooling basins, radioactive high-level waste (HLW) in underground storage tanks, and groundwater. Safety and regulatory requirements and economics require the removal of radiocesium before these wastes can be permanently disposed of. Electrically Switched Ion Exchange (ESIX) is an approach for radioactive cesium separation that combines IX and electrochemistry to provide a selective, reversible, and economic separation method that also produces little or no secondary waste. In the ESIX process, an electroactive IX film is deposited electrochemically onto a high-surface area electrode, and ion uptake and elution are controlled directly by modulating the potential of the film. For cesium, the electroactive films under investigation are ferrocyanides, which are well known to have high selectivities for cesium in concentrated sodium solutions. When a cathode potential is applied to the film, Fe{sup +3} is reduced to the Fe{sup +2} state, and a cation must be intercalated into the film to maintain charge neutrality (i.e., Cs{sup +} is loaded). Conversely, if an anodic potential is applied, a cation must be released from the film (i.e., Cs{sup +} is unloaded). Therefore, to load the film with cesium, the film is simply reduced; to unload cesium, the film is oxidized.

  7. Highly Stripped Ion Sources for MeV Ion Implantation

    Energy Technology Data Exchange (ETDEWEB)

    Hershcovitch, Ady

    2009-06-30

    Original technical objectives of CRADA number PVI C-03-09 between BNL and Poole Ventura, Inc. (PVI) were to develop an intense, high charge state, ion source for MeV ion implanters. Present day high-energy ion implanters utilize low charge state (usually single charge) ion sources in combination with rf accelerators. Usually, a MV LINAC is used for acceleration of a few rnA. It is desirable to have instead an intense, high charge state ion source on a relatively low energy platform (de acceleration) to generate high-energy ion beams for implantation. This de acceleration of ions will be far more efficient (in energy utilization). The resultant implanter will be smaller in size. It will generate higher quality ion beams (with lower emittance) for fabrication of superior semiconductor products. In addition to energy and cost savings, the implanter will operate at a lower level of health risks associated with ion implantation. An additional aim of the project was to producing a product that can lead to long­ term job creation in Russia and/or in the US. R&D was conducted in two Russian Centers (one in Tomsk and Seversk, the other in Moscow) under the guidance ofPVI personnel and the BNL PI. Multiple approaches were pursued, developed, and tested at various locations with the best candidate for commercialization delivered and tested at on an implanter at the PVI client Axcelis. Technical developments were exciting: record output currents of high charge state phosphorus and antimony were achieved; a Calutron-Bemas ion source with a 70% output of boron ion current (compared to 25% in present state-of-the-art). Record steady state output currents of higher charge state phosphorous and antimony and P ions: P{sup 2+} (8.6 pmA), P{sup 3+} (1.9 pmA), and P{sup 4+} (0.12 pmA) and 16.2, 7.6, 3.3, and 2.2 pmA of Sb{sup 3+} Sb {sup 4 +}, Sb{sup 5+}, and Sb{sup 6+} respectively. Ultimate commercialization goals did not succeed (even though a number of the products like high

  8. Ion beam assisted film growth

    CERN Document Server

    Itoh, T

    2012-01-01

    This volume provides up to date information on the experimental, theoretical and technological aspects of film growth assisted by ion beams.Ion beam assisted film growth is one of the most effective techniques in aiding the growth of high-quality thin solid films in a controlled way. Moreover, ion beams play a dominant role in the reduction of the growth temperature of thin films of high melting point materials. In this way, ion beams make a considerable and complex contribution to film growth. The volume will be essential reading for scientists, engineers and students working in thi

  9. ECR ion source based low energy ion beam facility

    Indian Academy of Sciences (India)

    A nanogan type of ECR source based on a fully permanent magnet design was chosen for this purpose [3]. The ECR ion source along with all its peripheral electron- ics and vacuum components placed on a 200 kV high voltage platform provides multiply charged positive ions in a widely varying energy range from a few ...

  10. Energy landscapes for mobile ions in ion conducting solids

    Indian Academy of Sciences (India)

    demonstrated here for a range of metaphosphate and diborate glasses, the complete description of the energy landscape for mobile ions also provides an effective tool for achieving a more detailed understanding of ion transport in glasses. The investigation of time evolutions can be included, if the bond valence analysis is ...

  11. Cold atomic beam ion source for focused ion beam applications

    Energy Technology Data Exchange (ETDEWEB)

    Knuffman, B.; Steele, A. V. [Center for Nanoscale Science and Technology, National Institute of Standards and Technology, Gaithersburg, Maryland 20899 (United States); Maryland Nanocenter, University of Maryland, College Park, Maryland 20742 (United States); zeroK NanoTech, Montgomery Village, Maryland 20886 (United States); McClelland, J. J. [Center for Nanoscale Science and Technology, National Institute of Standards and Technology, Gaithersburg, Maryland 20899 (United States)

    2013-07-28

    We report measurements and modeling of an ion source that is based on ionization of a laser-cooled atomic beam. We show a high brightness and a low energy spread, suitable for use in next-generation, high-resolution focused ion beam systems. Our measurements of total ion current as a function of ionization conditions support an analytical model that also predicts the cross-sectional current density and spatial distribution of ions created in the source. The model predicts a peak brightness of 2 × 10{sup 7} A m{sup −2} sr{sup −1} eV{sup −1} and an energy spread less than 0.34 eV. The model is also combined with Monte-Carlo simulations of the inter-ion Coulomb forces to show that the source can be operated at several picoamperes with a brightness above 1 × 10{sup 7} A m{sup −2} sr{sup −1} eV{sup −1}. We estimate that when combined with a conventional ion focusing column, an ion source with these properties could focus a 1 pA beam into a spot smaller than 1 nm. A total current greater than 5 nA was measured in a lower-brightness configuration of the ion source, demonstrating the possibility of a high current mode of operation.

  12. Ion trajectories in atom probe field ion microscopy and gas field ion sources

    CERN Document Server

    Castilho, C M C

    1999-01-01

    Trajectories of positive ions produced in a region close to a structured surface, modelled by spherical or spheroidal protrusions and kept at a positive electric potential with respect to a distant screen or detector are calculated. The results are discussed in comparison with similar practical situations produced by field ionization and field evaporation or desorption, such as those occurring in gas field ion sources, field ion microscopy and field desorption spectroscopy. (author)

  13. LEXUS heavy ion collisions

    CERN Document Server

    Sang Yong Jeon

    1997-01-01

    We use a Glauber-like approach to describe very energetic nucleus- nucleus collisions as a sequence of binary nucleon-nucleon collisions. No free parameters are needed: all the information comes from simple parametrizations of nucleon-nucleon collision data. Produced mesons are assumed not to interact with each other or with the original baryons. Comparisons are made to published experimental measurements of baryon rapidity and transverse momentum distributions, negative hadron rapidity and transverse momentum distributions, average multiplicities of pions, kaons, hyperons, and antihyperons, and zero degree energy distributions for sulfur-sulfur collisions at 200 GeV/c per nucleon and for lead-lead collisions at 158 GeV/c per nucleon. Good agreement is found except that the number of strange particles produced, especially antihyperons, is too small compared with experiment. We call this model LEXUS: Linear EXtrapolation of Ultrarelativistic nucleon-nucleon Scattering to heavy ion collisions. (11 refs).

  14. Optical Barium Ion Qubit

    CERN Document Server

    Yum, Dahyun; Dutta, Tarun; Mukherjee, Manas

    2016-01-01

    We demonstrate an optical single qubit based on 6S1/2 to 5D5/2 quadrupole transition of a single Ba+ ion operated by diode based lasers only. The resonance wavelength of the 6S1/2 to 5D5/2 quadrupole transition is about 1762 nm which suitably falls close to the U-band of the telecommunication wavelength. Thus this qubit is a naturally attractive choice towards implementation of quantum repeater or quantum networks using existing telecommunication networks. We observe continuous bit-flip oscillations at a rate of about 250 kHz which is fast enough for the qubit operation as compared to the measured coherence time of over 3 ms. We also present a technique to quantify the bit-flip error in each qubit NOT gate operation.

  15. Fast ion atomic spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Berry, H.G.; Young, L.; Goodman, L.S.; Somerville, L.P.; Hardis, J.; Neek, D.

    1984-01-01

    We have set up two collinear fast beam/laser excitation systems, one at the Argonne Dynamitron Accelerator (0.5 to 5.0 MeV beam energy) and another at a small electrostatic accelerator (20 to 130 keV). Our objective is to study fine structure, hyperfine structure and QED effects in ions of a few electrons. Initial projects underway include studies of multi-excited transitions in Li/sup -/ and Li/sup 0/, and transitions to high Rydberg states in H/sup 0/ and He/sup 0/. We have simultaneously excited a sodium jet with a laser at the resonance wavelength (D/sub 1/ or D/sub 2/ lines) and a 1-MeV He/sup +/ beam to produce excitation to autoionizing Na and Na/sup +/ states. The Auger electron spectra are compared to spectra obtained without laser excitation, and indicate strong variations in final state populations. 17 references.

  16. Ion-conducting membranes

    Energy Technology Data Exchange (ETDEWEB)

    Masel, Richard L.; Chen, Qingmei; Liu, Zengcai; Kutz, Robert

    2016-06-21

    An ion conducting polymeric composition mixture comprises a copolymer of styrene and vinylbenzyl-R.sub.s. R.sub.s is selected from the group consisting of imidazoliums and pyridiniums. The composition contains 10%-90% by weight of vinylbenzyl-R.sub.s. The composition can further comprise a polyolefin comprising substituted polyolefins, a polymer comprising cyclic amine groups, a polymer comprising at least one of a phenylene group and a phenyl group, a polyamide, and/or the reaction product of a constituent having two carbon-carbon double bonds. The composition can be in the form of a membrane. In a preferred embodiment, the membrane is a Helper Membrane that increases the faradaic efficiency of an electrochemical cell into which the membrane is incorporated, and also allows product formation at lower voltages than in cells without the Helper Membrane.

  17. Miniature Lightweight Ion Pump

    Science.gov (United States)

    Sinha, Mahadeva P.

    2010-01-01

    This design offers a larger surface area for pumping of active gases and reduces the mass of the pump by eliminating the additional vacuum enclosure. There are three main components to this ion pump: the cathode and anode pumping elements assembly, the vacuum enclosure (made completely of titanium and used as the cathode and maintained at ground potential) containing the assembly, and the external magnet. These components are generally put in a noble diode (or differential) configuration of the ion pump technology. In the present state of the art, there are two cathodes, one made of titanium and the other of tantalum. The anodes are made up of an array of stainless steel cylinders positioned between the two cathodes. All the elements of the pump are in a vacuum enclosure. After the reduction of pressure in this enclosure to a few microns, a voltage is applied between the cathode and the anode elements. Electrons generated by the ionization are accelerated toward the anodes that are confined in the anode space by the axial magnetic field. For the generation of the axial field along the anode elements, the magnet is designed in a C-configuration and is fabricated from rare earth magnetic materials (Nd-B-Fe or Sm-Co) possessing high energy product values, and the yoke is fabricated from the high permeability material (Hiperco-50A composed of Fe-Co-V). The electrons in this region collide with the gas molecules and generate their positive ions. These ions are accelerated into the cathode and eject cathode material (Ti). The neutral atoms deposit on the anode surfaces. Because of the chemical activity of Ti, the atoms combine with chemically active gas molecules (e.g. N2, O2, etc.) and remove them. New layers of Ti are continually deposited, and the pumping of active gases is thus accomplished. Pumping of the inert gases is accomplished by their burial several atomic layers deep into the cathode. However, they tend to re-emit if the entrapping lattice atoms are

  18. Ion-conducting membranes

    Energy Technology Data Exchange (ETDEWEB)

    Masel, Richard I.; Chen, Qingmei; Liu, Zengcai; Kutz, Robert

    2017-02-28

    An ion conducting polymeric composition mixture comprises a copolymer of styrene and vinylbenzyl-R.sub.s. R.sub.s is selected from the group consisting of imidazoliums, pyridiniums, pyrazoliums, pyrrolidiniums, pyrroliums, pyrimidiums, piperidiniums, indoliums, and triaziniums. The composition contains 10%-90% by weight of vinylbenzyl-R.sub.s. The composition can further comprise a polyolefin comprising substituted polyolefins, a polymer comprising cyclic amine groups, a polymer comprising at least one of a phenylene group and a phenyl group, a polyamide, and/or the reaction product of a constituent having two carbon-carbon double bonds. The composition can be in the form of a membrane. In a preferred embodiment, the membrane is a Helper Membrane that increases the faradaic efficiency of an electrochemical cell into which the membrane is incorporated, and also allows product formation at lower voltages than in cells without the Helper Membrane.

  19. A novel photoluminescent nanohybrid of poly(ε-caprolactone) grafted Mg/Al layered double hydroxides and Tb{sup 3+} ions: Synthesis and characterization

    Energy Technology Data Exchange (ETDEWEB)

    Bach, Long Giang [Department of Imaging System Engineering, Pukyong National University, Busan 608-737 (Korea, Republic of); Center for Advanced Materials Research, Nguyen Tat Thanh Unviersity, Ho Chi Minh City (Viet Nam); Islam, Md. Rafiqul [Department of Imaging System Engineering, Pukyong National University, Busan 608-737 (Korea, Republic of); Energy and Mineral Resources Division, Ministry of Power, Energy and Mineral Resources, Government of the People’s Republic of Bangladesh, Dhaka 1000 (Bangladesh); Cao, Xuan Thang [Department of Imaging System Engineering, Pukyong National University, Busan 608-737 (Korea, Republic of); Park, Jong Myung [Surface Engineering Laboratory, Graduate Institute of Ferrous Technology, Pohang University of Science and Technology (POSTECH), Pohang 790-784 (Korea, Republic of); Lim, Kwon Taek, E-mail: ktlim@pknu.ac.kr [Department of Imaging System Engineering, Pukyong National University, Busan 608-737 (Korea, Republic of)

    2014-01-05

    Highlights: • The photoluminescent LDHs-PCL-Tb{sup 3+} nanohybrid was successfully synthesized. • Structure and morphology of LDHs-g-PCL-Tb{sup 3+} were investigated by FT-IR, SEM, and TGA. • XPS and EDS analyses further suggested the formation of LDHs-g-PCL-Tb{sup 3+}. • Optical property of LDHs-g-PCL-Tb{sup 3+} was investigated by PL. -- Abstract: This paper demonstrates a systematic study of the synthesis and characterization of the hybrid of Mg–Al layer double hydroxides (LDHs), poly(ε-caprolactone) (PCL), and terbium ions (Tb{sup 3+}). The hybrid LDH-g-PCL-Tb{sup 3+}-1,10-phenanthroline (Phen) was prepared by the combination of ring opening polymerization (ROP), click chemistry, and coordination chemistry. First, LDHs with a molar ratio of Mg/Al = 2 were prepared by the co-precipitation method, which was subsequently functionalized with (3-chloropropyl) trimethoxysilane in order to introduce azide groups through the reaction of chlorine with sodium azide. Meanwhile, the acetylene functionalized PCL was prepared by ROP of ε-CL, followed by esterification of the hydroxyl groups using succinic anhydride. The click reaction of alkyne-PCL and N{sub 3}-LDHs successfully afforded LDH-g-PCL, which was coordinated with Tb{sup 3+} ions in the presence of Phen. The structure and properties of the nanohybrids were investigated by FT-IR, XPS, EDS, SEM, and TGA analyses. The data indicate the coordination of Tb{sup 3+} ions with LDH-g-PCL nanohybrids. The content of Tb{sup 3+} ions in the LDH-g-PCL-Tb{sup 3+}-Phen complex was calculated to be 8.7% (w/w). The LDH-g-PCL-Tb{sup 3+}-Phen complexes showed four emission bands with high fluorescence intensity centered at 489 nm ({sup 5}D{sub 4} → {sup 7}F{sub 6}), 546 nm ({sup 5}D{sub 4} → {sup 7}F{sub 5}), 586 nm ({sup 5}D{sub 4} → {sup 7}F{sub 4}) and 623 nm ({sup 5}D{sub 4} → {sup 7}F{sub 3}) with excitation at 328 nm ({sup 3}F{sub 6} → {sup 5}G{sub 6}). The stability of LDH-g-PCL-Tb{sup 3+}-Phen complexes

  20. Ion beams in materials processing and analysis

    CERN Document Server

    Schmidt, Bernd

    2012-01-01

    This book covers ion beam application in modern materials research, offering the basics of ion beam physics and technology and a detailed account of the physics of ion-solid interactions for ion implantation, ion beam synthesis, sputtering and nano-patterning.

  1. Holifield heavy ion research facility

    Energy Technology Data Exchange (ETDEWEB)

    Jones, C.M.; Alton, G.D.; Ball, J.B.; Biggerstaff, J.A.; Dowling, D.T.; Erb, K.A.; Haynes, D.L.; Hoglund, D.E.; Hudson, E.D.; Juras, R.C.

    1988-05-20

    Development of the Holifield facility has continued with resulting improvements in the number of ion species provided, in the ion energy for tandem-only operations, and in utilization efficiency. In this report, we describe our recent operational experience, development activities, and future development plans.

  2. Propagation of Ion Acoustic Perturbations

    DEFF Research Database (Denmark)

    Pécseli, Hans

    1975-01-01

    Equations describing the propagation of ion acoustic perturbations are considered, using the assumption that the electrons are Boltzman distributed and isothermal at all times. Quasi-neutrality is also considered.......Equations describing the propagation of ion acoustic perturbations are considered, using the assumption that the electrons are Boltzman distributed and isothermal at all times. Quasi-neutrality is also considered....

  3. High Resolution Scanning Ion Microscopy

    NARCIS (Netherlands)

    Castaldo, V.

    2011-01-01

    The structure of the thesis is the following. The first chapter is an introduction to scanning microscopy, where the path that led to the Focused Ion Beam (FIB) is described and the main differences between electrons and ion beams are highlighted. Chapter 2 is what is normally referred to (which I

  4. Quantum computing with trapped ions

    Energy Technology Data Exchange (ETDEWEB)

    Hughes, R.J.

    1998-01-01

    The significance of quantum computation for cryptography is discussed. Following a brief survey of the requirements for quantum computational hardware, an overview of the ion trap quantum computation project at Los Alamos is presented. The physical limitations to quantum computation with trapped ions are analyzed and an assessment of the computational potential of the technology is made.

  5. SPS Ion Induced Desorption Experiment

    CERN Multimedia

    Maximilien Brice

    2003-01-01

    This experiment will give a study about the induced desorption from heavy ion (Indium ion run from week 45 in SPS T4-H8 area) impacting LHC type graphite collimator. 4 different samples are located in the 4 chambers 90° one to each other: pure graphite, graphite with copper coating, graphite with NEG coating, 316LN stainless steal (reference).

  6. Bundle Security Protocol for ION

    Science.gov (United States)

    Burleigh, Scott C.; Birrane, Edward J.; Krupiarz, Christopher

    2011-01-01

    This software implements bundle authentication, conforming to the Delay-Tolerant Networking (DTN) Internet Draft on Bundle Security Protocol (BSP), for the Interplanetary Overlay Network (ION) implementation of DTN. This is the only implementation of BSP that is integrated with ION.

  7. Lithium ion storage between graphenes

    Directory of Open Access Journals (Sweden)

    Chan Yue

    2011-01-01

    Full Text Available Abstract In this article, we investigate the storage of lithium ions between two parallel graphene sheets using the continuous approximation and the 6-12 Lennard-Jones potential. The continuous approximation assumes that the carbon atoms can be replaced by a uniform distribution across the surface of the graphene sheets so that the total interaction potential can be approximated by performing surface integrations. The number of ion layers determines the major storage characteristics of the battery, and our results show three distinct ionic configurations, namely single, double, and triple ion forming layers between graphenes. The number densities of lithium ions between the two graphenes are estimated from existing semi-empirical molecular orbital calculations, and the graphene sheets giving rise to the triple ion layers admit the largest storage capacity at all temperatures, followed by a marginal decrease of storage capacity for the case of double ion layers. These two configurations exceed the maximum theoretical storage capacity of graphite. Further, on taking into account the charge-discharge property, the double ion layers are the most preferable choice for enhanced lithium storage. Although the single ion layer provides the least charge storage, it turns out to be the most stable configuration at all temperatures. One application of the present study is for the design of future high energy density alkali batteries using graphene sheets as anodes for which an analytical formulation might greatly facilitate rapid computational results.

  8. Anisotropic water reorientation around ions

    NARCIS (Netherlands)

    Tielrooij, K.J.; van der Post, S.T.; Hunger, J.; Bonn, M.; Bakker, H.J.

    2011-01-01

    We study the reorientation dynamics of water molecules around ions using terahertz dielectric relaxation spectroscopy and polarization-resolved femtosecond infrared pump-probe spectroscopy. The results are discussed in relation to the ion-specific Hofmeister series and the concomitant

  9. Nanofriction in cold ion traps.

    Science.gov (United States)

    Benassi, A; Vanossi, A; Tosatti, E

    2011-01-01

    Sliding friction between crystal lattices and the physics of cold ion traps are so far non-overlapping fields. Two sliding lattices may either stick and show static friction or slip with dynamic friction; cold ions are known to form static chains, helices or clusters, depending on the trapping conditions. Here we show, based on simulations, that much could be learnt about friction by sliding, through, for example, an electric field, the trapped ion chains over a corrugated potential. Unlike infinite chains, in which the theoretically predicted Aubry transition to free sliding may take place, trapped chains are always pinned. Yet, a properly defined static friction still vanishes Aubry-like at a symmetric-asymmetric structural transition, found for decreasing corrugation in both straight and zig-zag trapped chains. Dynamic friction is also accessible in ringdown oscillations of the ion trap. Long theorized static and dynamic one-dimensional friction phenomena could thus become accessible in future cold ion tribology.

  10. Logic gates with ion transistors

    Science.gov (United States)

    Grebel, H.

    2017-09-01

    Electronic logic gates are the basic building blocks of every computing and micro controlling system. Logic gates are made of switches, such as diodes and transistors. Ion-selective, ionic switches may emulate electronic switches [1-8]. If we ever want to create artificial bio-chemical circuitry, then we need to move a step further towards ion-logic circuitry. Here we demonstrate ion XOR and OR gates with electrochemical cells, and specifically, with two wet-cell batteries. In parallel to vacuum tubes, the batteries were modified to include a third, permeable and conductive mid electrode (the gate), which was placed between the anode and cathode in order to affect the ion flow through it. The key is to control the cell output with a much smaller biasing power, as demonstrated here. A successful demonstration points to self-powered ion logic gates.

  11. The ATLAS positive ion injector

    Energy Technology Data Exchange (ETDEWEB)

    Shepard, K.W.; Bollinger, L.M.; Pardo, R.C.

    1990-01-01

    This paper reviews the design, construction status, and beam tests to date of the positive ion injector (PII) which is replacing the tandem injector for the ATLAS heavy-ion facility. PII consists of an ECR ion source on a 350 KV platform injecting a very low velocity superconducting linac. The linac is composed of an independently-phased array of superconducting four-gap interdigital resonators which accelerate over a velocity range of .006 to .05c. In finished form, PII will be able to inject ions as heavy as uranium into the existing ATLAS linac. Although at the present time little more than 50% of the linac is operational, the indenpently-phased array is sufficiently flexible that ions in the lower half of the periodic table can be accelerated and injected into ATLAS. Results of recent operational experience will be discussed. 5 refs.

  12. Logic Gates with Ion Transistors

    CERN Document Server

    Grebel, Haim

    2016-01-01

    Electronic logic gates are the basic building blocks of every computing and micro controlling system. Logic gates are made of switches, such as diodes and transistors. Ion-selective, ionic switches may emulate electronic switches [1-8]. If we ever want to create artificial bio-chemical circuitry, then we need to move a step further towards ion-logic circuitry. Here we demonstrate ion XOR and OR gates with electrochemical cells, and specifically, with two wet-cell batteries. In parallel to vacuum tubes, the batteries were modified to include a third, permeable and conductive mid electrode (the gate), which was placed between the anode and cathode in order to affect the ion flow through it. The key is to control the cell output with a much smaller biasing power, as demonstrated here. A successful demonstration points to self-powered ion logic gates.

  13. Ion-Molecule Reaction Dynamics.

    Science.gov (United States)

    Meyer, Jennifer; Wester, Roland

    2017-05-05

    We review the recent advances in the investigation of the dynamics of ion-molecule reactions. During the past decade, the combination of single-collision experiments in crossed ion and neutral beams with the velocity map ion imaging detection technique has enabled a wealth of studies on ion-molecule reactions. These methods, in combination with chemical dynamics simulations, have uncovered new and unexpected reaction mechanisms, such as the roundabout mechanism and the subtle influence of the leaving group in anion-molecule nucleophilic substitution reactions. For this important class of reactions, as well as for many fundamental cation-molecule reactions, the information obtained with crossed-beam imaging is discussed. The first steps toward understanding micro-solvation of ion-molecule reaction dynamics are presented. We conclude with the presentation of several interesting directions for future research.

  14. Ions kinematics in an electrostatic ion beam trap

    Energy Technology Data Exchange (ETDEWEB)

    Attia, D

    2004-06-01

    In this study, I have tried to provide a better understanding of the dynamics of ions inside an electrostatic ion beam trap. The electrostatic ion trap allows to store ions moving between two electrostatic mirrors. Although the trap has been developed already seven years ago, no direct measurement of the transversal velocity distribution of the ions has been performed. Such quantity is central for understanding the conditions under which a beam should be produced (mainly emittance) in order to be trapped by such a device. The data I have obtained during the course of this work are based on an experimental technique which relies on the direct imaging of the particles exiting the trap, as well as on numerical simulations of the ion trajectories inside the trap. I have personally been involved in the hardware development of the imaging system, the data acquisition and analysis of the data as well as il all numerical calculations presented here. These results allow us to obtain, for the first time, experimental information on the transverse phase space of the trap, and contribute to the overall understanding of the ion motion in this system. (author)

  15. Ion Rings for Magnetic Fusion

    Energy Technology Data Exchange (ETDEWEB)

    Greenly, John, B.

    2005-07-31

    This Final Technical Report presents the results of the program, Ion Rings for Magnetic Fusion, which was carried out under Department of Energy funding during the period August, 1993 to January, 2005. The central objective of the program was to study the properties of field-reversed configurations formed by ion rings. In order to reach this objective, our experimental program, called the Field-reversed Ion Ring Experiment, FIREX, undertook to develop an efficient, economical technology for the production of field-reversed ion rings. A field-reversed configuration (FRC) in which the azimuthal (field-reversing) current is carried by ions with gyro-radius comparable to the magnetic separatrix radius is called a field-reversed ion ring. A background plasma is required for charge neutralization of the ring, and this plasma will be confined within the ring's closed magnetic flux. Ion rings have long been of interest as the basis of compact magnetic fusion reactors, as the basis for a high-power accelerator for an inertial fusion driver, and for other applications of high power ion beams or plasmas of high energy density. Specifically, the FIREX program was intended to address the longstanding question of the contribution of large-orbit ions to the observed stability of experimental FRCs to the MHD tilt mode. Typical experimental FRCs with s {approx} 2-4, where s is the ratio of separatrix radius to ion gyro-radius, have been stable to tilting, but desired values for a fusion reactor, s > 20, should be unstable. The FIREX ring would consist of a plasma with large s for the background ions, but with s {approx} 1 for the ring ions. By varying the proportions of these two populations, the minimum proportion of large-orbit ions necessary for stability could be determined. The incorporation of large-orbit ions, perhaps by neutral-beam injection, into an FRC has been advanced for the purpose of stabilizing, heating, controlling angular momentum, and aiding the formation

  16. Data acquisition for the HILI (Heavy Ion Light Ion) detector

    Energy Technology Data Exchange (ETDEWEB)

    Teh, K.M.; Shapira, D.; McConnell, J.W.; Kim, H.; Novotny, R.

    1987-01-01

    A large acceptance, multi-segmented detector system capable of the simultaneous detection of heavy and light ions has been constructed. The heavy ions are detected with a segmented gas ionization chamber and a multiwire proportional counter while the light ions are detected with a 192 element plastic phoswich hodoscope. Processing the large number of signals is accomplished through a combination of CAMAC and FASTBUS modules and preprocessors, and a Host minicomputer. Details of the data acquisition system and the reasons for adopting a dual standards system are discussed. In addition, a technique for processing signals from an individual hodoscope detector is presented. 4 refs., 3 figs.

  17. Ion beam analysis of metal ion implanted surfaces

    Energy Technology Data Exchange (ETDEWEB)

    Evans, P.J.; Chu, J.W.; Johnson, E.P.; Noorman, J.T. [Australian Nuclear Science and Technology Organisation, Lucas Heights, NSW (Australia); Sood, D.K. [Royal Melbourne Inst. of Tech., VIC (Australia)

    1993-12-31

    Ion implantation is an established method for altering the surface properties of many materials. While a variety of analytical techniques are available for the characterisation of implanted surfaces, those based on particle accelerators such as Rutherford backscattering (RBS) and nuclear reaction analysis (NRA) provide some of the most useful and powerful for this purpose. Application of the latter techniques to metal ion implantation research at ANSTO will be described with particular reference to specific examples from recent studies. Where possible, the information obtained from ion beam analysis will be compared with that derived from other techniques such as Energy Dispersive X-ray (EDX) and Auger spectroscopies. 4 refs., 5 figs.

  18. High Current Ion Sources and Injectors for Heavy Ion Fusion

    Energy Technology Data Exchange (ETDEWEB)

    Kwan, Joe W.

    2005-02-15

    Heavy ion beam driven inertial fusion requires short ion beam pulses with high current and high brightness. Depending on the beam current and the number of beams in the driver system, the injector can use a large diameter surface ionization source or merge an array of small beamlets from a plasma source. In this paper, we review the scaling laws that govern the injector design and the various ion source options including the contact ionizer, the aluminosilicate source, the multicusp plasma source, and the MEVVA source.

  19. Rearrangement reactions in ion-ion and ion-atom collisions: results and problems

    Energy Technology Data Exchange (ETDEWEB)

    Presnyakov, L.P. [Lebedev Physical Institute, Moscow (Russian Federation); Tawara, H.

    1997-01-01

    Recent experimental and theoretical results are discussed for ionic collisions with large cross sections at intermediate and small energies of the relative motion. Single- and double-electron removal from H{sup -} ions in slow collisions with other ions is considered in more details. The theoretical methods are discussed from the viewpoint of general requirements of scattering theory. (author)

  20. Three-dimensional simulations of ion dynamics in an Electron Cyclotron Resonance Ion Source

    NARCIS (Netherlands)

    Beijers, J. P. M.; Mironov, V.

    We present a three-dimensional simulation of the ion dynamics in an electron cyclotron resonance ion source. Ion trajectories in the min-B field of the source are calculated taking ion-ion and electron-ion collisions into account. The electrons are not tracked but considered as a neutralizing

  1. Behavior of Time-Resolved Ion Energy Distribution Functions during Ion-Ion Instability

    Science.gov (United States)

    Saitou, Yoshifumi; Nakamura, Yoshiharu; Tanaka, Masayoshi; Komori, Akio; Kawai, Yoshinobu

    1993-10-01

    When an external RF field is applied to an ion beam plasma system, ion-ion instability is suppressed at f/fii≳1, where f and fii are the frequency of the external RF field and the peak frequency of the instability, respectively. It is also observed that the time-averaged energy distribution function of the ion beam broadens when the instability is suppressed. In order to investigate the cause of this broadening, time-resolved energy distribution functions of ions are measured with a boxcar integrator. As a result, it is found that the energy distribution functions periodically change with the external RF field and the above broadening is apparently caused by the time-averaging of the energy distribution functions.

  2. Triple ion beam irradiation facility

    Energy Technology Data Exchange (ETDEWEB)

    Lewis, M.B.; Allen, W.R.; Buhl, R.A.; Packan, N.H.; Cook, S.W.; Mansur, L.K.

    1988-12-01

    A unique ion irradiation facility consisting of three accelerators is described. The accelerators can be operated simultaneously to deliver three ion beams on one target sample. The energy ranges of the ions are 50 to 400 keV, 200 keV to 2.5 MeV, and 1.0 to 5.0 MeV. Three different ions in the appropriate mass range can be simultaneously implanted to the same depth in a target specimen as large as 100 mm/sup 2/ in area. Typical depth ranges are 0.1 to 1.0 ..mu..m. The X-Y profiles of all three ion beams are measured by a system of miniature Faraday cups. The low-voltage accelerator can periodically ramp the ion beam energy during the implantation. Three different types of target chambers are in use at this facility. The triple-beam high-vacuum chamber can hold nine transmission electron microscopy specimens at elevated temperature during a irradiation by the three simultaneous beams. A second high-vacuum chamber on the medium-voltage accelerator beamline houses a low- and high-temperature translator and a two-axis goniometer for ion channeling measurements. The third chamber on the high-energy beamline can be gas-filled for special stressed specimen irradiations. Special applications for the surface modification of materials with this facility are described. Appendixes containing operating procedures are also included. 18 refs., 27 figs., 1 tab.

  3. DIVALENT ION EXCHANGE WITH ALKALI

    Energy Technology Data Exchange (ETDEWEB)

    Bunge, A.L.; Klein, G.; Radke, C.J.

    1980-05-01

    Exchange of hardness ions is important in enhanced oil recovery with chemical additives. In both micellar-polymer and caustic flooding processes, multivalent ions released from rock surfaces can interact with anionic surfactants, rendering them preferentially oil soluble and/or insoluble in water. Because hardness cations are sparingly soluble and precipitate in alkaline solutions, such solutions may be more efficient as surfactant flood preflushes than are softened brines. Multivalent ion precipitation may also occur in alkaline waterflooding. To permit design of such processes, this paper presents a chromatographic theory for simultaneous ion exchange with precipitation of divalent ions. Theoretical effluent histories and concentration profiles are presented for the cases of finite pulses and continuous injection of hydroxide ions into linear cores. Complete capture of the insoluble salt particles is assumed. Results are given for the case of instantaneous equilibration of the solution with the precipitate, as well for the case of complete nonequilibrium, in which the solid precipitate does not redissolve. The efficiency of alklaine preflushing is shown to depend on the exchange isotherm, initial divalent loading of the rock, injected pH and salinity, the solubility product of the precipitated salt, and pulse size. The effect of slug size on complete equilibrium removal of hardness ions is reduced efficiency with increasing size until a critical volume approximating continuous injection is reached. Increasing injected pH and salinity provides a more favorable response. Experimental data for Berea sandstone and an argillaceous sand compare favorably with the proposed theory.

  4. Electrically Switched Cesium Ion Exchange

    Energy Technology Data Exchange (ETDEWEB)

    JPH Sukamto; ML Lilga; RK Orth

    1998-10-23

    This report discusses the results of work to develop Electrically Switched Ion Exchange (ESIX) for separations of ions from waste streams relevant to DOE site clean-up. ESIX combines ion exchange and electrochemistry to provide a selective, reversible method for radionuclide separation that lowers costs and minimizes secondary waste generation typically associated with conventional ion exchange. In the ESIX process, an electroactive ion exchange film is deposited onto. a high surface area electrode, and ion uptake and elution are controlled directly by modulating the potential of the film. As a result, the production of secondary waste is minimized, since the large volumes of solution associated with elution, wash, and regeneration cycles typical of standard ion exchange are not needed for the ESIX process. The document is presented in two parts: Part I, the Summary Report, discusses the objectives of the project, describes the ESIX concept and the approach taken, and summarizes the major results; Part II, the Technology Description, provides a technical description of the experimental procedures and in-depth discussions on modeling, case studies, and cost comparisons between ESIX and currently used technologies.

  5. Ultrarelativistic heavy ions

    Energy Technology Data Exchange (ETDEWEB)

    Pugh, H.G.

    1980-12-01

    Studies with ultrarelativistic heavy ions combine aspects of cosmic ray physics, particle physics, nuclear physics, astrophysics and cosmogenesis. The leading theoretical concerns are the behavior of matter at very high-energy density and flux, the general behavior of space time in collisions, relativistic nuclear theory, and quantum chromodynamics. The field has developed over a period of more than thirty years, since the first observation of heavy nuclei in cosmic rays and the major developments of understanding of high-energy collisions made by Fermi and Landau in the early fifties. In the late sixties the discovery of the parton content of nucleons was rapidly followed by a great extension of high-energy collision phenomenology at the CERN ISR and subsequent confirmation of the QCD theory. In parallel the study of p-nucleus and nucleus-nucleus collisions at very high energies, especially at the CERN PS, Fermilab and the Bevalac, and in cosmic rays demonstrated that studies involving the nucleus opened up a new dimension in studies of the hadronic interaction. It is now at a high level of interest on an international scale, with major new accelerators being proposed to dedicate to this kind of study.

  6. LHC Report: Ion Age

    CERN Multimedia

    John Jowett for the LHC team

    2013-01-01

    The LHC starts the New Year facing a new challenge: proton-lead collisions in the last month before the shutdown in mid-February.    Commissioning this new and almost unprecedented mode of collider operation is a major challenge both for the LHC and its injector chain. Moreover, it has to be done very quickly to achieve a whole series of physics goals, requiring modifications of the LHC configuration, in a very short time. These include a switch of the beam directions halfway through the run, polarity reversals of the ALICE spectrometer magnet and Van der Meer scans.    The Linac3 team kept the lead source running throughout the end-of-year technical stop, and recovery of the accelerator complex was very quick. New proton and lead beams were soon ready, with a bunch filling pattern that ensures they will eventually match up in the LHC. The LEIR machine has even attained a new ion beam intensity record.  On Friday 11 January the first single bunches o...

  7. Laser induced fluorescence of trapped molecular ions

    Energy Technology Data Exchange (ETDEWEB)

    Grieman, F.J.

    1979-10-01

    An experimental apparatus for obtaining the optical spectra of molecular ions is described. The experimental technique includes the use of three dimensional ion trapping, laser induced fluorescence, and gated photon counting methods. The ions, which are produced by electron impact, are confined in a radio-frequency quadrupole ion trap of cylindrical design. Because the quadrupole ion trap allows mass selection of the molecular ion desired for study, the analysis of the spectra obtained is greatly simplified. The ion trap also confines the ions to a region easily probed by a laser beam. 18 references.

  8. Ion Exchange and Liquid Column Chromatography.

    Science.gov (United States)

    Walton, Harold F.

    1980-01-01

    Emphasizes recent advances in principles and methodology in ion exchange and chromatography. Two tables list representative examples for inorganic ions and organic compounds. Cites 544 references. (CS)

  9. Plasma ion sources and ion beam technology inmicrofabrications

    Energy Technology Data Exchange (ETDEWEB)

    Ji, Lili [Univ. of California, Berkeley, CA (United States)

    2007-01-01

    For over decades, focused ion beam (FIB) has been playing a very important role in microscale technology and research, among which, semiconductor microfabrication is one of its biggest application area. As the dimensions of IC devices are scaled down, it has shown the need for new ion beam tools and new approaches to the fabrication of small-scale devices. In the meanwhile, nanotechnology has also deeply involved in material science research and bioresearch in recent years. The conventional FIB systems which utilize liquid gallium ion sources to achieve nanometer scale resolution can no longer meet the various requirements raised from such a wide application area such as low contamination, high throughput and so on. The drive towards controlling materials properties at nanometer length scales relies on the availability of efficient tools. In this thesis, three novel ion beam tools have been developed and investigated as the alternatives for the conventional FIB systems in some particular applications. An integrated focused ion beam (FIB) and scanning electron microscope (SEM) system has been developed for direct doping or surface modification. This new instrument employs a mini-RF driven plasma source to generate focused ion beam with various ion species, a FEI two-lens electron (2LE) column for SEM imaging, and a five-axis manipulator system for sample positioning. An all-electrostatic two-lens column has been designed to focus the ion beam extracted from the source. Based on the Munro ion optics simulation, beam spot sizes as small as 100 nm can be achieved at beam energies between 5 to 35 keV if a 5 μm-diameter extraction aperture is used. Smaller beam spot sizes can be obtained with smaller apertures at sacrifice of some beam current. The FEI 2LE column, which utilizes Schottky emission, electrostatic focusing optics, and stacked-disk column construction, can provide high-resolution (as small as 20 nm) imaging capability, with fairly long working distance (25

  10. Ion guiding in alumina capillaries

    DEFF Research Database (Denmark)

    Juhász, Z.; Sulik, B.; Biri, S.

    2009-01-01

    Transmission of a few keV impact energy Ne ions through capillaries in anodic alumina membranes has been studied with different ion counting methods using an energy dispersive electrostatic spectrometer, a multichannel plate (MCP) array and sensitive current-measurement. In the present work, we...... focus our attention to the measurements with the MCP array. The alumina capillaries were prepared by electro-chemical oxidation of aluminium foils. For the present experiments guiding of 3-6 keV Ne ions has been studied in two samples with capillary diameter of about 140 nm and 260 nm and with capillary...

  11. Intermediate ions in the atmosphere

    Science.gov (United States)

    Tammet, Hannes; Komsaare, Kaupo; Hõrrak, Urmas

    2014-01-01

    Intermediate air ions are charged nanometer-sized aerosol particles with an electric mobility of about 0.03-0.5 cm2 V- 1 s- 1 and a diameter of about 1.5-7.5 nm. Intensive studies of new particle formation provided good knowledge about intermediate ions during burst events of atmospheric aerosol nucleation. Information about intermediate ions during quiet periods between the bursts remained poor. The new mobility analyzer SIGMA can detect air ions at concentrations of mobility fractions of about 1 cm- 3 and enables studying intermediate ions during quiet periods. It became evident that intermediate ions always exist in atmospheric air and should be considered an indicator and a mediator of aerosol nucleation. The annual average concentration of intermediate ions of one polarity in Tartu, Estonia, was about 40 cm- 3 while 5% of the measurements showed a concentration of less than 10 cm- 3. The fraction concentrations in logarithmic 1/8-decade mobility bins between 0.1 and 0.4 cm2 V- 1 s- 1 often dropped below 1 cm- 3. The bursts of intermediate ions at stations separated by around 100 km appeared to be correlated. The lifespan of intermediate ions in the atmosphere is a few minutes, and they cannot be carried by wind over long distances. Thus the observed long-range correlation of intermediate ions is explained by simultaneous changes in air composition in widely spaced stations. A certain amount of intermediate ion bursts, predominantly of negative polarity, are produced by the balloelectric effect at the splashing of water drops during rain. These bursts are usually excluded when speaking about new particle formation because the balloelectric particles are assumed not to grow to the size of the Aitken mode. The mobility distribution of balloelectric ions is uniform in shape in all measurements. The maximum is located at a mobility of about 0.2 cm2 V- 1 s- 1, which corresponds to the diameter of particles of about 2.5 nm.

  12. The emerging role of ion/ion reactions in biological mass spectrometry: considerations for reagent ion selection.

    Science.gov (United States)

    McLuckey, Scott A

    2010-01-01

    The advent of ionization methods that can produce multiply charged gaseous ions has enabled the development of gas-phase ion/ion reactions in analytical mass spectrometry. Ion/ion chemistry has proved to be a particularly effective means for converting ions from one type to another and allows for a decoupling of the ionization method from the nature of the ion subjected to tandem mass spectrometry. A growing array of applications has been developed based on a variety of reaction types, including electron transfer, proton transfer, charge inversion, metal transfer, etc. Most ion/ion reactions take place following the formation of a stable bound orbit between the reactants. As reactants approach closely enough for chemistry to occur, they can react by small charged particle transfer (i.e. electron transfer and proton transfer) at crossing points in the interaction potential. Alternatively, the reactants can collide to form a relatively long-lived complex. A wide range of chemical reactions can result from the long-lived complex, which include multiple charged particle transfers and covalent bond formation. For a given analyte ion, the major reaction pathway is determined by the characteristics of the reagent ion. An appreciation of the factors that underlie the partitioning of ion/ion reaction products is important in the design and selection of reagent ions to effect transformations of interest. Important considerations for reagent ion selection are discussed here within the context of a generalized scheme for ion/ion reaction dynamics.

  13. Fully variational average atom model with ion-ion correlations.

    Science.gov (United States)

    Starrett, C E; Saumon, D

    2012-02-01

    An average atom model for dense ionized fluids that includes ion correlations is presented. The model assumes spherical symmetry and is based on density functional theory, the integral equations for uniform fluids, and a variational principle applied to the grand potential. Starting from density functional theory for a mixture of classical ions and quantum mechanical electrons, an approximate grand potential is developed, with an external field being created by a central nucleus fixed at the origin. Minimization of this grand potential with respect to electron and ion densities is carried out, resulting in equations for effective interaction potentials. A third condition resulting from minimizing the grand potential with respect to the average ion charge determines the noninteracting electron chemical potential. This system is coupled to a system of point ions and electrons with an ion fixed at the origin, and a closed set of equations is obtained. Solution of these equations results in a self-consistent electronic and ionic structure for the plasma as well as the average ionization, which is continuous as a function of temperature and density. Other average atom models are recovered by application of simplifying assumptions.

  14. Negative Ions in Space.

    Science.gov (United States)

    Millar, Thomas J; Walsh, Catherine; Field, Thomas A

    2017-02-08

    Until a decade ago, the only anion observed to play a prominent role in astrophysics was H - . The bound-free transitions in H - dominate the visible opacity in stars with photospheric temperatures less than 7000 K, including the Sun. The H - anion is also believed to have been critical to the formation of molecular hydrogen in the very early evolution of the Universe. Once H 2 formed, about 500 000 years after the Big Bang, the expanding gas was able to lose internal gravitational energy and collapse to form stellar objects and "protogalaxies", allowing the creation of heavier elements such as C, N, and O through nucleosynthesis. Although astronomers had considered some processes through which anions might form in interstellar clouds and circumstellar envelopes, including the important role that polycyclic aromatic hydrocarbons might play in this, it was the detection in 2006 of rotational line emission from C 6 H - that galvanized a systematic study of the abundance, distribution, and chemistry of anions in the interstellar medium. In 2007, the Cassini mission reported the unexpected detection of anions with mass-to-charge ratios of up to ∼10 000 in the upper atmosphere of Titan; this observation likewise instigated the study of fundamental chemical processes involving negative ions among planetary scientists. In this article, we review the observations of anions in interstellar clouds, circumstellar envelopes, Titan, and cometary comae. We then discuss a number of processes by which anions can be created and destroyed in these environments. The derivation of accurate rate coefficients for these processes is an essential input for the chemical kinetic modeling that is necessary to fully extract physics from the observational data. We discuss such models, along with their successes and failings, and finish with an outlook on the future.

  15. Applications of ion beam technology

    Science.gov (United States)

    Gelerinter, E.; Spielberg, N.

    1980-01-01

    Wire adhesion in steel belted radial tires; carbon fibers and composite; cold welding, brazing, and fabrication; hydrogen production, separation, and storage; membrane use; catalysis; sputtering and texture; and ion beam implantation are discussed.

  16. Ion bombardment in RF photoguns

    Energy Technology Data Exchange (ETDEWEB)

    Pozdeyev,E.; Kayran, D.; Litvinenko, V. N.

    2009-05-04

    A linac-ring eRHIC design requires a high-intensity CW source of polarized electrons. An SRF gun is viable option that can deliver the required beam. Numerical simulations presented elsewhere have shown that ion bombardment can occur in an RF gun, possibly limiting lifetime of a NEA GaAs cathode. In this paper, we analytically solve the equations of motion of ions in an RF gun using the ponderomotive potential of the Rf field. We apply the method to the BNL 1/2-cell SRF photogun and demonstrate that a significant portion of ions produced in the gun can reach the cathode if no special precautions are taken. Also, the paper discusses possible mitigation techniques that can reduce the rate of ion bombardment.

  17. Ion Cyclotron Resonance Facility (ICR)

    Data.gov (United States)

    Federal Laboratory Consortium — his facility is charged with developing and exploiting the unique capabilities of Fourier Transform Ion Cyclotron Resonance (FT-ICR) mass spectrometry, and leads the...

  18. Ion manipulation method and device

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, Gordon A.; Baker, Erin M.; Smith, Richard D.; Ibrahim, Yehia M.

    2017-11-07

    An ion manipulation method and device is disclosed. The device includes a pair of substantially parallel surfaces. An array of inner electrodes is contained within, and extends substantially along the length of, each parallel surface. The device includes a first outer array of electrodes and a second outer array of electrodes. Each outer array of electrodes is positioned on either side of the inner electrodes, and is contained within and extends substantially along the length of each parallel surface. A DC voltage is applied to the first and second outer array of electrodes. A RF voltage, with a superimposed electric field, is applied to the inner electrodes by applying the DC voltages to each electrode. Ions either move between the parallel surfaces within an ion confinement area or along paths in the direction of the electric field, or can be trapped in the ion confinement area.

  19. Hydrated interfacial ions and electrons.

    Science.gov (United States)

    Abel, Bernd

    2013-01-01

    Charged particles such as hydrated ions and transient hydrated electrons, the simplest anionic reducing agents in water, and the special hydronium and hydroxide ions at water interfaces play an important role in many fields of science, such as atmospheric chemistry, radiation chemistry, and biology, as well as biochemistry. This article focuses on these species near hydrophobic interfaces of water, such as the air or vacuum interface of water or water protein/membrane interfaces. Ions at interfaces as well as solvated electrons have been reviewed frequently during the past decade. Although all species have been known for some time with seemingly familiar features, recently the picture in all cases became increasingly diffuse rather than clearer. The current account gives a critical state-of-the art overview of what is known and what remains to be understood and investigated about hydrated interfacial ions and electrons.

  20. Emissive Ion Thruster -EMIT Project

    Data.gov (United States)

    National Aeronautics and Space Administration — A propulsion system is proposed that is based on acceleration of ions emitted from a thin, solid-state electrochemical ceramic membrane. This technology would...

  1. Modeling the Lithium Ion Battery

    Science.gov (United States)

    Summerfield, John

    2013-01-01

    The lithium ion battery will be a reliable electrical resource for many years to come. A simple model of the lithium ions motion due to changes in concentration and voltage is presented. The battery chosen has LiCoO[subscript 2] as the cathode, LiPF[subscript 6] as the electrolyte, and LiC[subscript 6] as the anode. The concentration gradient and…

  2. Ion association in natural brines

    Science.gov (United States)

    Truesdell, A.H.; Jones, B.F.

    1969-01-01

    Natural brines, both surface and subsurface, are highly associated aqueous solutions. Ion complexes in brines may be ion pairs in which the cation remains fully hydrated and the bond between the ions is essentially electrostatic, or coordination complexes in which one or more of the hydration water molecules are replaced by covalent bonds to the anion. Except for Cl-, the major simple ions in natural brines form ion pairs; trace and minor metals in brines form mainly coordination complexes. Limitations of the Debye-Hu??ckel relations for activity coefficients and lack of data on definition and stability of all associated species in concentrated solutions tend to produce underestimates of the degree of ion association, except where the brines contain a very high proportion of Cl-. Data and calculations on closed basin brines of highly varied composition have been coupled with electrode measurements of single-ion activities in an attempt to quantify the degree of ion association. Such data emphasize the role of magnesium complexes. Trace metal contents of closed basin brines are related to complexes formed with major anions. Alkaline sulfo- or chlorocarbonate brines (western Great Basin) carry significant trace metal contents apparently as hydroxides or hydroxy polyions. Neutral high chloride brines (Bonneville Basin) are generally deficient in trace metals. With a knowledge of the thermodynamic properties of a natural water, many possible reactions with other phases (solids, gases, other liquids) may be predicted. A knowledge of these reactions is particularly important in the study of natural brines which may be saturated with many solid phases (silicates, carbonates, sulfates, etc.), which may have a high pH and bring about dissolution of other phases (silica, amphoteric hydroxides, CO2, etc.), and which because of their high density may form relatively stable interfaces with dilute waters. ?? 1969.

  3. Principles of Magnetospheric Ion Composition.

    Science.gov (United States)

    1984-12-17

    BOREAL ) OF SIANDARDS-1963-A REPRODUtCED AT GOVERNMENT EXPENSE REPORT SD-TR-84-57 IC) Principles of Magnetospheric Ion Composition M. SCHULZ Space...species by different amounts. Entry of ionospheric ions into the plasma sheet seems to occur primarily through afternoon- and evening-sector auroral arcs...rather than through the polar wind as had previously been postulated. Energization occurs through interaction with the auroral potential structure

  4. Ion currents in diesel engines

    OpenAIRE

    Rao, Rahul

    2017-01-01

    This thesis documents an experimental and modelling investigation into ion formation in diesel engines, its uses in the field of engine performance and emissions prediction and the mechanisms by which these uses are made possible. Ion sensors have been employed in engines for a variety of purposes, including estimation of air-fuel ratio, start of combustion and in-cylinder pressure, detection of knock, misfire and combustion resonance, prediction of soot formation, and control of spark ...

  5. Heavy ion therapy: Bevalac epoch

    Energy Technology Data Exchange (ETDEWEB)

    Castro, J.R.

    1993-10-01

    An overview of heavy ion therapy at the Bevelac complex (SuperHILac linear accelerator + Bevatron) is given. Treatment planning, clinical results with helium ions on the skull base and uveal melanoma, clinical results with high-LET charged particles, neon radiotherapy of prostate cancer, heavy charged particle irradiation for unfavorable soft tissue sarcoma, preliminary results in heavy charged particle irradiation of bone sarcoma, and irradiation of bile duct carcinoma with charged particles and-or photons are all covered. (GHH)

  6. Intracellular ion channels and cancer

    OpenAIRE

    Luigi eLeanza; Lucia eBiasutto; Antonella eManago; Erich eGulbins; Mario eZoratti; Ildikò eSzabò

    2013-01-01

    Several types of channels play a role in the maintenance of ion homeostasis in subcellular organelles including endoplasmatic reticulum, nucleus, lysosome, endosome, and mitochondria. Here we give a brief overview of the contribution of various mitochondrial and other organellar channels to cancer cell proliferation or death. Much attention is focused on channels involved in intracellular calcium signaling and on ion fluxes in the ATP-producing organelle mitochondria. Mitochondrial K+ channel...

  7. Dissociative Recombination of Complex Ions

    Science.gov (United States)

    Mitchell, J. Brian A.

    1999-10-01

    The FALP-MS apparatus at the University of Rennes allows the measurement of rate coefficients for the recombination of molecular ions to be made (at 300K) even though several ions may be present in the afterglow. The recombination of a number of hydrocarbon ions derived from alkane ( Lehfaoui et al. J. Chem. Phys. 106, 5406, 1997.), alkene ( Rebrion-Rowe et al. J. Chem. Phys. 108, 7185, 1998.) and aromatic (Rebrion-Rowe et al. (Submitted to J. Chem. Phys.)) parent molecules has been studied. Despite the wide range of complexity of these compounds, the measured recombination rates are remarkably similar having values in the range of 4-10-7 cm^3.s-1. Plans are being laid for a new version of this apparatus that will allow pre-prepared ions to be injected into the inert buffer gas flow. This will allow reactive ions to be studied as well as halogen containing ions whose recombination rates would normally be masked by electron attachment to their parent gases in a conventional flowing afterglow apparatus. A high temperature modification to the CRESU supersonic flow apparatus (J.L. Le Garrec et al. J. Chem. Phys. 107, 54, 1997.) in our laboratory will allow electron attachment to radicals to be studied by means of the mass spectrometric detection of products, Langmuir probe measurement of the electron density in the flow and Laser Induced Fluorescent identification of the radical species. Such measurements are needed for the modeling of semiconductor processing plasmas.

  8. Ion Bernstein wave heating research

    Energy Technology Data Exchange (ETDEWEB)

    Ono, Masayuki.

    1992-03-01

    Ion Bernstein wave heating (IBWH) utilizes the ion Bernstein wave (IBW), a hot plasma wave, to carry the radio frequency (rf) power to heat tokamak reactor core. Earlier wave accessibility studies have shown that this finite-Larmor-radius (FLR) mode should penetrate into a hot dense reactor plasma core without significant attenuation. Moreover, the IBW's low phase velocity ({omega}/k{sub {perpendicular}} {approx} V{sub Ti} {much lt} V{sub {alpha}}) greatly reduces the otherwise serious wave absorption by the 3.5 MeV fusion {alpha}-particles. In addition, the property of IBW's that k{sub {perpendicular}} {rho}{sub i} {approx} 1 makes localized bulk ion heating possible at the ion cyclotron harmonic layers. Such bulk ion heating can prove useful in optimizing fusion reactivity. In another vein, with proper selection of parameters, IBW's can be made subject to strong localized electron Landau damping near the major ion cyclotron harmonic resonance layers. This property can be useful, for example, for rf current drive in the reactor plasma core. This paper discusses this research.

  9. Ion Bernstein wave heating research

    Energy Technology Data Exchange (ETDEWEB)

    Ono, Masayuki

    1992-03-01

    Ion Bernstein wave heating (IBWH) utilizes the ion Bernstein wave (IBW), a hot plasma wave, to carry the radio frequency (rf) power to heat tokamak reactor core. Earlier wave accessibility studies have shown that this finite-Larmor-radius (FLR) mode should penetrate into a hot dense reactor plasma core without significant attenuation. Moreover, the IBW`s low phase velocity ({omega}/k{sub {perpendicular}} {approx} V{sub Ti} {much_lt} V{sub {alpha}}) greatly reduces the otherwise serious wave absorption by the 3.5 MeV fusion {alpha}-particles. In addition, the property of IBW`s that k{sub {perpendicular}} {rho}{sub i} {approx} 1 makes localized bulk ion heating possible at the ion cyclotron harmonic layers. Such bulk ion heating can prove useful in optimizing fusion reactivity. In another vein, with proper selection of parameters, IBW`s can be made subject to strong localized electron Landau damping near the major ion cyclotron harmonic resonance layers. This property can be useful, for example, for rf current drive in the reactor plasma core. This paper discusses this research.

  10. Cyclotron transitions of bound ions

    Science.gov (United States)

    Bezchastnov, Victor G.; Pavlov, George G.

    2017-06-01

    A charged particle in a magnetic field possesses discrete energy levels associated with particle rotation around the field lines. The radiative transitions between these levels are the well-known cyclotron transitions. We show that a bound complex of particles with a nonzero net charge displays analogous transitions between the states of confined motion of the entire complex in the field. The latter bound-ion cyclotron transitions are affected by a coupling between the collective and internal motions of the complex and, as a result, differ from the transitions of a "reference" bare ion with the same mass and charge. We analyze the cyclotron transitions for complex ions by including the coupling within a rigorous quantum approach. Particular attention is paid to comparison of the transition energies and oscillator strengths to those of the bare ion. Selection rules based on integrals of collective motion are derived for the bound-ion cyclotron transitions analytically, and the perturbation and coupled-channel approaches are developed to study the transitions quantitatively. Representative examples are considered and discussed for positive and negative atomic and cluster ions.

  11. Low Z impurity ion extraction from TFTR ion sources

    Energy Technology Data Exchange (ETDEWEB)

    Kamperschroer, J.H.; Grisham, L.R.; Newman, R.A.; O' Connor, T.E.; Stevenson, T.N.; von Halle, A.; Williams, M.D.; Wright, K.E.

    1993-04-01

    TFTR deuterium neutral beams have been operated unintentionally with significant quantities of extracted water ions. Water has been observed with an Optical Multichannel Analyzer (OMA) during beam extraction when small water leaks were present within the arc chamber. These leaks were thermally induced with the contamination level increasing linearly with pulse length. 6% of the beam current was attributed to water ions for the worst leak, corresponding to an instantaneous value of 12% at the end of a 1.5 s pulse. A pre-calorimeter collimator was damaged as a result of this operation. A similar contamination is observed during initial operation of ion sources exposed to air. This latter contamination is attributed to the synthesis, from adsorbed air, of either D[sub 2]O or the indistinguishable ND[sub 3]. Initial operation of new ion sources typically produces a contamination level of [approximately]2%. These impurities are reduced to undetectable levels after 50 to 100 beam pulses. Once a water molecule is present in the plasma generator, it is predominantly ionized rather than dissociated, resulting in the extraction of only trace amounts of hydrogenated ions. The addition of water to the extracted beam also reduces the optimum perveance, moving the typical underdense operating point closer to optimum, causing the frequency of grid faults to increase. Close to 90% of the water extracted from ion sources with water leaks was deuterated, implying that the potential exists for the production of tritiated water during TFTR's forthcoming DT operation. Isotope exchange in the plasma generator takes place rapidly and is believed to be surface catalyzed. The primary concern is with O implanted into beam absorbers recombining with tritium, and the subsequent hold up of T[sub 2]O on cryopanels. Continuous surveillance with the OMA diagnostic during DT operation will ensure that ion sources with detectable water are not operated with tritium.

  12. Low Z impurity ion extraction from TFTR ion sources

    Energy Technology Data Exchange (ETDEWEB)

    Kamperschroer, J.H.; Grisham, L.R.; Newman, R.A.; O`Connor, T.E.; Stevenson, T.N.; von Halle, A.; Williams, M.D.; Wright, K.E.

    1993-04-01

    TFTR deuterium neutral beams have been operated unintentionally with significant quantities of extracted water ions. Water has been observed with an Optical Multichannel Analyzer (OMA) during beam extraction when small water leaks were present within the arc chamber. These leaks were thermally induced with the contamination level increasing linearly with pulse length. 6% of the beam current was attributed to water ions for the worst leak, corresponding to an instantaneous value of 12% at the end of a 1.5 s pulse. A pre-calorimeter collimator was damaged as a result of this operation. A similar contamination is observed during initial operation of ion sources exposed to air. This latter contamination is attributed to the synthesis, from adsorbed air, of either D{sub 2}O or the indistinguishable ND{sub 3}. Initial operation of new ion sources typically produces a contamination level of {approximately}2%. These impurities are reduced to undetectable levels after 50 to 100 beam pulses. Once a water molecule is present in the plasma generator, it is predominantly ionized rather than dissociated, resulting in the extraction of only trace amounts of hydrogenated ions. The addition of water to the extracted beam also reduces the optimum perveance, moving the typical underdense operating point closer to optimum, causing the frequency of grid faults to increase. Close to 90% of the water extracted from ion sources with water leaks was deuterated, implying that the potential exists for the production of tritiated water during TFTR`s forthcoming DT operation. Isotope exchange in the plasma generator takes place rapidly and is believed to be surface catalyzed. The primary concern is with O implanted into beam absorbers recombining with tritium, and the subsequent hold up of T{sub 2}O on cryopanels. Continuous surveillance with the OMA diagnostic during DT operation will ensure that ion sources with detectable water are not operated with tritium.

  13. On a cryogenic noble gas ion catcher

    NARCIS (Netherlands)

    Dendooven, P; Purushothaman, S; Gloos, K

    2006-01-01

    In situ purification of the gas used as stopping medium in a noble gas ion catcher by operating the device at low temperatures of 60-150 K was investigated. Alpha-decay recoil ions from a Ra-223 source served as energetic probes. The combined ion survival and transport efficiencies for Rn-219 ions

  14. A sensitive fluorescent sensor of lanthanide ions

    CERN Document Server

    Bekiari, V; Lianos, P

    2003-01-01

    A fluorescent probe bearing a diazostilbene chromophore and a benzo-15-crown-5 ether moiety is a very efficient sensor of lanthanide ions. The ligand emits strong fluorescence only in the presence of specific ions, namely lanthanide ions, while the emission wavelength is associated with a particular ion providing high sensitivity and resolution.

  15. Scanning reflection ion microscopy in a helium ion microscope

    Directory of Open Access Journals (Sweden)

    Yuri V. Petrov

    2015-05-01

    Full Text Available Reflection ion microscopy (RIM is a technique that uses a low angle of incidence and scattered ions to form an image of the specimen surface. This paper reports on the development of the instrumentation and the analysis of the capabilities and limitations of the scanning RIM in a helium ion microscope (HIM. The reflected ions were detected by their “conversion” to secondary electrons on a platinum surface. An angle of incidence in the range 5–10° was used in the experimental setup. It was shown that the RIM image contrast was determined mostly by surface morphology but not by the atomic composition. A simple geometrical analysis of the reflection process was performed together with a Monte Carlo simulation of the angular dependence of the reflected ion yield. An interpretation of the RIM image formation and a quantification of the height of the surface steps were performed. The minimum detectable step height was found to be approximately 5 nm. RIM imaging of an insulator surface without the need for charge compensation was successfully demonstrated.

  16. Observations of strong ion-ion correlations in dense plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Ma, T.; Fletcher, L.; Pak, A.; Chapman, D. A.; Falcone, R. W.; Fortmann, C.; Galtier, E.; Gericke, D. O.; Gregori, G.; Hastings, J.; Landen, O. L.; Le Pape, S.; Lee, H. J.; Nagler, B.; Neumayer, P.; Turnbull, D.; Vorberger, J.; White, T. G.; Wünsch, K.; Zastrau, U.; Glenzer, S. H.; Döppner, T.

    2014-05-01

    Using simultaneous spectrally, angularly, and temporally resolved x-ray scattering, we measure the pronounced ion-ion correlation peak in a strongly coupled plasma. Laser-driven shock-compressed aluminum at ~3× solid density is probed with high-energy photons at 17.9 keV created by molybdenum He-α emission in a laser-driven plasma source. The measured elastic scattering feature shows a well-pronounced correlation peak at a wave vector of k=4k=4Å-1. The magnitude of this correlation peak cannot be described by standard plasma theories employing a linear screened Coulomb potential. Advanced models, including a strong short-range repulsion due to the inner structure of the aluminum ions are however in good agreement with the scattering data. These studies have demonstrated a new highly accurate diagnostic technique to directly measure the state of compression and the ion-ion correlations. We have since applied this new method in single-shot wave-number resolved S(k) measurements to characterize the physical properties of dense plasmas.

  17. Ion beam analysis fundamentals and applications

    CERN Document Server

    Nastasi, Michael; Wang, Yongqiang

    2015-01-01

    Ion Beam Analysis: Fundamentals and Applications explains the basic characteristics of ion beams as applied to the analysis of materials, as well as ion beam analysis (IBA) of art/archaeological objects. It focuses on the fundamentals and applications of ion beam methods of materials characterization.The book explains how ions interact with solids and describes what information can be gained. It starts by covering the fundamentals of ion beam analysis, including kinematics, ion stopping, Rutherford backscattering, channeling, elastic recoil detection, particle induced x-ray emission, and nucle

  18. Modification of graphene by ion beam

    Science.gov (United States)

    Gawlik, G.; Ciepielewski, P.; Jagielski, J.; Baranowski, J.

    2017-09-01

    Ion induced defect generation in graphene was analyzed using Raman spectroscopy. A single layer graphene membrane produced by chemical vapor deposition (CVD) on copper foil and then transferred on glass substrate was subjected to helium, carbon, nitrogen, argon and krypton ions bombardment at energies from the range 25 keV to 100 keV. A density of ion induced defects and theirs mean size were estimated by using Raman measurements. Increasing number of defects generated by ion with increase of ion mass and decrease of ion energy was observed. Dependence of ion defect efficiency (defects/ion) on ion mass end energy was proportional to nuclear stopping power simulated by SRIM. No correlation between ion defect efficiency and electronic stopping power was observed.

  19. Cyclotron axial ion-beam-buncher system

    Energy Technology Data Exchange (ETDEWEB)

    Hamm, R.W.; Swenson, D.A.; Wangler, T.P.

    1982-02-11

    Adiabatic ion bunching is achieved in a cyclotron axial ion injection system through the incorporation of a radio frequency quadrupole system, which receives ions from an external ion source via an accelerate-decelerate system and a focusing einzel lens system, and which adiabatically bunches and then injects the ions into the median plane of a cyclotron via an electrostatic quadrupole system and an inflection mirror.

  20. The ion pairs and superconducting bosons

    OpenAIRE

    Minasyan, V. N.

    2008-01-01

    First, it is shown that the creation of the spinless ion pairs in the lattice, which are hold by the binding with neighbor ion pairs together regarded as covalent. These ion pairs are created by the repulsive potential interaction of two ions which is bound as linear oscillator. The repulsive S-wave scattering between ion pairs and electrons is transformed to the attractive effective interaction between electrons which leads to a creation of electron pairs by a binding energy depending on the...

  1. Maskless, resistless ion beam lithography

    Energy Technology Data Exchange (ETDEWEB)

    Ji, Qing [Univ. of California, Berkeley, CA (United States)

    2003-01-01

    As the dimensions of semiconductor devices are scaled down, in order to achieve higher levels of integration, optical lithography will no longer be sufficient for the needs of the semiconductor industry. Alternative next-generation lithography (NGL) approaches, such as extreme ultra-violet (EUV), X-ray, electron-beam, and ion projection lithography face some challenging issues with complicated mask technology and low throughput. Among the four major alternative NGL approaches, ion beam lithography is the only one that can provide both maskless and resistless patterning. As such, it can potentially make nano-fabrication much simpler. This thesis investigates a focused ion beam system for maskless, resistless patterning that can be made practical for high-volume production. In order to achieve maskless, resistless patterning, the ion source must be able to produce a variety of ion species. The compact FIB system being developed uses a multicusp plasma ion source, which can generate ion beams of various elements, such as O2+, BF2+, P+ etc., for surface modification and doping applications. With optimized source condition, around 85% of BF2+, over 90% of O2+ and P+ have been achieved. The brightness of the multicusp-plasma ion source is a key issue for its application to maskless ion beam lithography. It can be substantially improved by optimizing the source configuration and extractor geometry. Measured brightness of 2 keV He+ beam is as high as 440 A/cm2 • Sr, which represents a 30x improvement over prior work. Direct patterning of Si thin film using a focused O2+ ion beam has been investigated. A thin surface oxide film can be selectively formed using 3 keV O2+ ions with the dose of 1015 cm-2. The oxide can then serve as a hard mask for patterning of the Si film. The

  2. Marine Toxins Targeting Ion Channels

    Directory of Open Access Journals (Sweden)

    Hugo R. Arias

    2006-04-01

    Full Text Available Abstract: This introductory minireview points out the importance of ion channels for cell communication. The basic concepts on the structure and function of ion channels triggered by membrane voltage changes, the so-called voltage-gated ion channels (VGICs, as well as those activated by neurotransmitters, the so-called ligand-gated ion channel (LGICs, are introduced. Among the most important VGIC superfamiles, we can name the voltage-gated Na+ (NaV, Ca2+ (CaV, and K+ (KV channels. Among the most important LGIC super families, we can include the Cys-loop or nicotinicoid, the glutamate-activated (GluR, and the ATP-activated (P2XnR receptor superfamilies. Ion channels are transmembrane proteins that allow the passage of different ions in a specific or unspecific manner. For instance, the activation of NaV, CaV, or KV channels opens a pore that is specific for Na+, Ca2+, or K+, respectively. On the other hand, the activation of certain LGICs such as nicotinic acetylcholine receptors, GluRs, and P2XnRs allows the passage of cations (e.g., Na+, K+, and/or Ca2+, whereas the activation of other LGICs such as type A γ-butyric acid and glycine receptors allows the passage of anions (e.g., Cl− and/or HCO3−. In this regard, the activation of NaV and CaV as well as ligand-gated cation channels produce membrane depolarization, which finally leads to stimulatory effects in the cell, whereas the activation of KV as well as ligand-gated anion channels induce membrane hyperpolarization that finally leads to inhibitory effects in the cell. The importance of these ion channel superfamilies is emphasized by considering their physiological functions throughout the body as well as their pathophysiological implicance in several neuronal diseases. In this regard, natural molecules, and especially marine toxins, can be potentially used as modulators (e.g., inhibitors or prolongers of ion channel functions to treat or to alleviate a specific

  3. THOR Ion Mass Spectrometer (IMS)

    Science.gov (United States)

    Retinò, Alessandro

    2017-04-01

    Turbulence Heating ObserveR (THOR) is the first mission ever flown in space dedicated to plasma turbulence. The Ion Mass Spectrometer (IMS) onboard THOR will provide the first high-time resolution measurements of mass-resolved ions in near-Earth space, focusing on hot ions in the foreshock, shock and magnetosheath turbulent regions. These measurements are required to study how kinetic-scale turbulent fluctuations heat and accelerate different ion species. IMS will measure the full three-dimensional distribution functions of main ion species (H+, He++, O+) in the energy range 10 eV/q to 30 keV/q with energy resolution DE/E down to 10% and angular resolution down to 11.25˚ . The time resolution will be 150 ms for O+, 300 ms for He++ and ˜ 1s for O+, which correspond to ion scales in the the foreshock, shock and magnetosheath regions. Such high time resolution is achieved by mounting four identical IMS units phased by 90˚ in the spacecraft spin plane. Each IMS unit combines a top-hat electrostatic analyzer with deflectors at the entrance together with a time-of-flight section to perform mass selection. Adequate mass-per-charge resolution (M/q)/(ΔM/q) (≥ 8 for He++ and ≥ 3 for O+) is obtained through a 6 cm long Time-of-Flight (TOF) section. IMS electronics includes a fast sweeping high voltage board that is required to make measurements at high cadence. Ion detection includes Micro Channel Plates (MCPs) combined with Application-Specific Integrated Circuits (ASICs) for charge amplification and discrimination and a discrete Time-to-Amplitude Converter (TAC) to determine the ion time of flight. A processor board will be used to for ion events formatting and will interface with the Particle Processing Unit (PPU), which will perform data processing for THOR particle detectors. The IMS instrument is being designed and will be built and calibrated by an international consortium of scientific institutes from France, USA, Germany and Japan and Switzerland.

  4. Ionomers for Ion-Conducting Energy Materials

    Science.gov (United States)

    Colby, Ralph

    For ionic actuators and battery separators, it is vital to utilize single-ion conducting ionomers that avoid the detrimental polarization of other ions. Single-ion conducting ionomers are synthesized based on DFT calculations, with low glass transition temperatures (facile dynamics) to prepare ion-conducting membranes for battery separators that conduct Li+ or Na+. Characterization by X-ray scattering, dielectric spectroscopy, FTIR, NMR and linear viscoelasticity collectively develop a coherent picture of ionic aggregation and both counterion and polymer dynamics. 7Li NMR diffusion measurements find that diffusion is faster than expected by conductivity using the Nernst-Einstein equation, which means that the majority of Li diffusion occurs by ion pairs moving with the polymer segmental motion. Segmental motion only contributes to ionic conduction in the rare event that one of these ion pairs has an extra Li (a positive triple ion). This leads us to a new metric for ion-conducting soft materials, the product of the cation number density p0 and their diffusion coefficient D; p0D is the diffusive flux of lithium ions. This new metric has a maximum at intermediate ion content that corresponds to the overlap of ion pair polarizability volumes. At higher ion contents, the ion pairs interact strongly and form larger aggregation states that retard segmental motion of both mobile ion pairs and triple ions.

  5. Numerical Simulation of Ion Rings and Ion Beam Propagation.

    Science.gov (United States)

    Mankofsky, Alan

    This thesis presents the development of numerical simulation techniques for studying the physics of ion beams and rings in a background plasma as applicable to certain problems in magnetic and inertial confinement fusion. Two codes have been developed for these purposes: RINGA and CIDER. The 2 and 1/2-dimensional (r,z,v(,r),v(,(theta)),v(,z); (PAR-DIFF)/(PAR-DIFF)(theta) = 0) particle code RINGA follows the trajectories of ions in their self-consistent magnetic field. The code assumes strict charge neutrality and admits currents only in the azimuthal direction, i.e., (PHI) = J(,r) = J(,z) = 0. The injection and resistive trapping of ion rings has been studied with RINGA. The number of particles trapped as a fraction of the total number injected N is found to be strongly dependent upon (1) N (in the range 2.85 x 10('16) - 3.99 x 10('17)) and (2) mirror ratios in the system (1.05 -1.14), and more weakly dependent upon (3) wall resistance per unit length (0.72 (OMEGA)/cm - 1.80 (OMEGA)/cm) and (4) beam divergence (0(DEGREES)-6(DEGREES)). Fractions of trapped particles in excess of 0.9 have been observed. Modifications to RINGA to include finite pressure of confined plasma and beam ion-electron slowing down collisions are discussed. Finite plasma pressure leads to a diamagnetic current which increases the field reversal factor in ion ring equilibria, while causing the closed flux surfaces to expand outward. The ideal magnetohydrodynamic stability of the plasma is analyzed in the high toroidal mode number limit, where the beam ions are noninteracting. The existence of stable high-(beta) equilibria is demonstrated. One such equilibrium, stable to both ideal interchange and ballooning modes, has (TBOND) 8(pi) / (DBLTURN) 55%. In the CIDER hybrid code, ions are represented by particles and electrons by an inertialess thermal fluid which obeys a generalized Ohm's law. Fields are solved in the quasineutral Darwin approximation. Several collisional and atomic processes are

  6. Characterization of ISOLDE ion source and ion source chemistry

    CERN Document Server

    Barbeau, Marion

    2014-01-01

    This report presents results of measurements made with the ISOLDE OFF-LINE mass separator [1]. The first part shows measurements of the ionization characteristics of noble gases in a VADIS ion source. The goal of the measurements was to determine the dependency of the extractable current of first and second noble gases ions with the electron energy. In the second part, investigation on in-target chemistry are presented. Here, the effect of injected sulfur hexafluoride ($SF_6$) on the release of oxygen from aluminium oxide ($Al_2 O_3$) was studied.

  7. Industrial ion sources broadbeam gridless ion source technology

    CERN Document Server

    Zhurin, Viacheslav V

    2012-01-01

    Due to the large number of uses of ion sources in academia and industry, those who utilize these sources need up to date and coherent information to keep themselves abreast of developments and options, and to chose ideal solutions for quality and cost-effectiveness. This book, written by an author with a strong industrial background and excellent standing, is the comprehensive guide users and developers of ion sources have been waiting for. Providing a thorough refresher on the physics involved, this resource systematically covers the source types, components, and the operational parameters.

  8. Heavy ion fusion--Using heavy ions to make electricity

    Energy Technology Data Exchange (ETDEWEB)

    Celata, C.M.

    2004-03-15

    The idea of using nuclear fusion as a source of commercial electrical power has been pursued worldwide since the 1950s. Two approaches, using magnetic and inertial confinement of the reactants, are under study. This paper describes the difference between the two approaches, and discusses in more detail the heavy-ion-driven inertial fusion concept. A multibeam induction linear accelerator would be used to bring {approx}100 heavy ion beams to a few GeV. The beams would then heat and compress a target of solid D-T. This approach is unique among fusion concepts in its ability to protect the reaction chamber wall from neutrons and debris.

  9. Cholesterol binding to ion channels

    Directory of Open Access Journals (Sweden)

    Irena eLevitan

    2014-02-01

    Full Text Available Numerous studies demonstrated that membrane cholesterol is a major regulator of ion channel function. The goal of this review is to discuss significant advances that have been recently achieved in elucidating the mechanisms responsible for cholesterol regulation of ion channels. The first major insight that comes from growing number of studies that based on the sterol specificity of cholesterol effects, show that several types of ion channels (nAChR, Kir, BK, TRPV are regulated by specific sterol-protein interactions. This conclusion is supported by demonstrating direct saturable binding of cholesterol to a bacterial Kir channel. The second major advance in the field is the identification of putative cholesterol binding sites in several types of ion channels. These include sites at locations associated with the well-known cholesterol binding motif CRAC and its reversed form CARC in nAChR, BK, and TRPV, as well as novel cholesterol binding regions in Kir channels. Notably, in the majority of these channels, cholesterol is suggested to interact mainly with hydrophobic residues in non-annular regions of the channels being embedded in between transmembrane protein helices. We also discuss how identification of putative cholesterol binding sites is an essential step to understand the mechanistic basis of cholesterol-induced channel regulation. Clearly, however, these are only the first few steps in obtaining a general understanding of cholesterol-ion channels interactions and their roles in cellular and organ functions.

  10. Heavy-ion nucleus scattering

    CERN Document Server

    Rahman, M A; Haque, S

    2003-01-01

    Heavy ion-nucleus scattering is an excellent laboratory to probe high spin phenomena, exotic nuclei and for the analysis of various exit channels. The Strong Absorption Model or the generalized diffraction models, which are semi-classical in nature, have been employed in the description of various heavy ion-nucleus scattering phenomena with reasonable success. But one needs to treat the deflection function (scattering angles) quantum mechanically in the Wave Mechanical picture for the appropriate description of the heavy-ion nucleus scattering phenomena. We have brought the mathematics for the cross-section of the heavy-ion nucleus scattering to an analytic expression taking account of the deflection function (scattering angles) quantum mechanically. sup 9 Be, sup 1 sup 6 O, sup 2 sup 0 Ne and sup 3 sup 2 S heavy-ion beams elastic scattering from sup 2 sup 8 Si, sup 2 sup 4 Mg and sup 4 sup 0 Ca target nuclei at various projectile energies over the range 20-151 MeV have been analysed in terms of the 2-paramet...

  11. Rotation sensing with trapped ions

    Science.gov (United States)

    Campbell, W. C.; Hamilton, P.

    2017-03-01

    We present a protocol for rotation measurement via matter-wave Sagnac interferometry using trapped ions. The ion trap based interferometer encloses a large area in a compact apparatus through repeated round-trips in a Sagnac geometry. We show how a uniform magnetic field can be used to close the interferometer over a large dynamic range in rotation speed and measurement bandwidth without contrast loss. Since this technique does not require the ions to be confined in the Lamb-Dicke regime, Doppler laser cooling should be sufficient to reach a sensitivity of { S }=1.4× {10}-6 {{rad}} {{{s}}}-1 {{{H}}{{z}}}-1/2. , which features invited work from the best early-career researchers working within the scope of J. Phys. B. This project is part of the Journal of Physics series’ 50th anniversary celebrations in 2017. Wes Campbell was selected by the Editorial Board of J. Phys. B as an Emerging Leader.

  12. Results of heavy ion radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Castro, J.R. [Lawrence Berkeley Lab., CA (United States). Life Sciences Div.

    1994-04-01

    The potential of heavy ion therapy for clinical use in cancer therapy stems from the biological parameters of heavy charged particles, and their precise dose localization. Biologically, carbon, neon and other heavy ion beams (up to about silicon) are clinically useful in overcoming the radioresistance of hypoxic tumors, thus increasing biological effectiveness relative to low-LET x-ray or electron beams. Cells irradiated by heavy ions show less variation in cell-cycle related radiosensitivity and decreased repair of radiation injury. The physical parameters of these heavy charged particles allow precise delivery of high radiation doses to tumors while minimizing irradiation of normal tissues. Clinical use requires close interaction between radiation oncologists, medical physicists, accelerator physicists, engineers, computer scientists and radiation biologists.

  13. Miniature Bipolar Electrostatic Ion Thruster

    Science.gov (United States)

    Hartley, Frank T.

    2006-01-01

    The figure presents a concept of a bipolar miniature electrostatic ion thruster for maneuvering a small spacecraft. The ionization device in the proposed thruster would be a 0.1-micron-thick dielectric membrane with metal electrodes on both sides. Small conical holes would be micromachined through the membrane and electrodes. An electric potential of the order of a volt applied between the membrane electrodes would give rise to an electric field of the order of several mega-volts per meter in the submicron gap between the electrodes. An electric field of this magnitude would be sufficient to ionize all the molecules that enter the holes. In a thruster-based on this concept, one or more propellant gases would be introduced into such a membrane ionizer. Unlike in larger prior ion thrusters, all of the propellant molecules would be ionized. This thruster would be capable of bipolar operation. There would be two accelerator grids - one located forward and one located aft of the membrane ionizer. In one mode of operation, which one could denote the forward mode, positive ions leaving the ionizer on the backside would be accelerated to high momentum by an electric field between the ionizer and an accelerator grid. Electrons leaving the ionizer on the front side would be ejected into free space by a smaller accelerating field. The equality of the ion and electron currents would eliminate the need for an additional electron- or ion-emitting device to keep the spacecraft charge-neutral. In another mode of operation, which could denote the reverse mode, the polarities of the voltages applied to the accelerator grids and to the electrodes of the membrane ionizer would be the reverse of those of the forward mode. The reversal of electric fields would cause the ion and electrons to be ejected in the reverse of their forward mode directions, thereby giving rise to thrust in the direction opposite that of the forward mode.

  14. Ion Implantation and Synthesis of Materials

    CERN Document Server

    Nastasi, Michael

    2006-01-01

    Ion implantation is one of the key processing steps in silicon integrated circuit technology. Some integrated circuits require up to 17 implantation steps and circuits are seldom processed with less than 10 implantation steps. Controlled doping at controlled depths is an essential feature of implantation. Ion beam processing can also be used to improve corrosion resistance, to harden surfaces, to reduce wear and, in general, to improve materials properties. This book presents the physics and materials science of ion implantation and ion beam modification of materials. It covers ion-solid interactions used to predict ion ranges, ion straggling and lattice disorder. Also treated are shallow-junction formation and slicing silicon with hydrogen ion beams. Topics important for materials modification, such as ion-beam mixing, stresses, and sputtering, are also described.

  15. Fast ion-atom and ion-molecule collisions

    CERN Document Server

    2013-01-01

    The principal goal of this book is to provide state-of-the art coverage of the non-relativistic three- and four-body theories at intermediate and high energy ion-atom and ion-molecule collisions. The focus is on the most frequently studied processes: electron capture, ionization, transfer excitation and transfer ionization. The content is suitable both for graduate students and experienced researchers. For these collisions, the literature has seen enormous renewal of activity in the development and applications of quantum-mechanical theories. This subject is of relevance in several branches of science and technology, like accelerator-based physics, the search for new sources of energy and high temperature fusion of light ions. Other important applications are in life sciences via medicine, where high-energy ion beams are used in radiotherapy for which a number of storage ring accelerators are in full operation, under construction or planned to be built worldwide. Therefore, it is necessary to review this fiel...

  16. Ion-Beam-Excited, Electrostatic, Ion Cyclotron Instability

    DEFF Research Database (Denmark)

    Michelsen, Poul; Pécseli, Hans; Juul Rasmussen, Jens

    1977-01-01

    The stability limits of the ion‐beam‐excited, electrostatic, ion cyclotron instability were investigated in a Q‐machine plasma where the electrons could be heated by microwaves. In agreement with theory, the beam energy necessary for excitation decreased with increasing electron temperature....

  17. Ion-Beam-Excited Electrostatic Ion Cyclotron Instability

    DEFF Research Database (Denmark)

    Michelsen, Poul; Pécseli, Hans; Juul Rasmussen, Jens

    1977-01-01

    The stability limits of the ion‐beam‐excited, electrostatic, ion cyclotron instability were investigated in a Q‐machine plasma where the electrons could be heated by microwaves. In agreement with theory, the beam energy necessary for excitation decreased with increasing electron temperature....

  18. Low Energy Ion Implanting of Silver Ion in Titanium

    Directory of Open Access Journals (Sweden)

    Fernanda Elisa Demore Palandi

    2014-08-01

    Full Text Available In modern medicine, biomaterials have been widely used as implants. Among biomaterials, titanium medical class is distinguished by its high degree of biocompatibility. However, orthoses and prostheses infected with post-implanted microorganisms require surgeries and medical interventions that are costly and treatment can take months. To combat infections associated with implants, the best strategy is to prevent them from occurring. One strategy is the silver ion implantation in titanium. In this work, silver ions were implanted at low energies (4 keV in medical titanium with the goal to take bactericide titanium surface and therefore, inhibit biofilm formation. The implantation was done using the Ion Plating equipment. After ion implantation, the samples were analyzing for Rutherford Backscattering Spectrometry, Glow-Discharge Optical Emission Spectroscopy and X-Ray Diffraction. The results show that the silver was implanted at depths up to 10 nm, corroborating simulation data. In addition, the strategy used in this work can be applied on an industrial scale due to the type of equipment used for the surface treatment.

  19. Heavy ions: Report from Relativistic Heavy Ion Collider

    Indian Academy of Sciences (India)

    We review selected highlights from the experiments at the Relativistic Heavy Ion Collider (RHIC) exploring the QCD phase diagram. A wealth of new results appeared recently from RHIC due to major recent upgrades, like for example the Υ suppression in central nucleus-nucleus collisions which has been discovered ...

  20. Ion composition variety and variability around perihelion

    Science.gov (United States)

    Beth, Arnaud; Altwegg, Kathrin; Behar, Étienne; Broiles, Tom; Burch, Jim; Carr, Christopher; Eriksson, Anders; Galand, Marina; Goetz, Charlotte; Henri, Pierre; Heritier, Kévin; Nilsson, Hans; Odelstad, Elias; Richter, Ingo; Rubin, Martin; Vallieres, Xavier

    2017-04-01

    For two years, the Double Focusing Mass Spectrometer (DFMS), one of the Rosetta Orbiter Spectrometer for Ion and Neutral Analysis (ROSINA) onboard Rosetta probed the neutral gas and the plasma composition of the comet 67P/Churyumov-Gerasimenko's coma (67P). Major ion species detected include water ions (e.g, H2O+, H3O+, HO+) observed throughout the escorting phase. The analysis of DFMS data revealed a large zoo of ion species near perihelion (summer 2015). In particular, protonated versions of high proton affinity neutrals (e.g., NH4+) were detected, but also hydrocarbon and organic ion species. Near perihelion, ion composition was also highly variable and showed interesting variations in the complexity of the observed ion species. We will first present an overview of the rich variety of ion species observed during perihelion. This study will be supported by ionospheric modeling of ion composition below the ion exobase. We will then show an intercomparison between DFMS data and Rosetta Plasma Consortium (RPC) plasma and particle data to interpret the DFMS ion composition variability. Our primary goal is to highlight any correlation between observations from these different instruments (i.e. ion composition, ion and electron number density, energy distribution, magnetic field) and to find relevant signatures of physical processes which can affect the chemistry and dynamics (e.g., acceleration and deflection) of the involved neutral and ion species.

  1. Therapeutic approaches to ion channel diseases.

    Science.gov (United States)

    Camerino, Diana Conte; Desaphy, Jean-François; Tricarico, Domenico; Pierno, Sabata; Liantonio, Antonella

    2008-01-01

    More than 400 genes are known that encode ion channel subunits. In addition, alternative splicing and heteromeric assembly of different subunits increase tremendously the variety of ion channels. Such many channels are needed to accomplish very complex cellular functions, whereas dysfunction of ion channels are key events in many pathological processes. The recent discovery of ion channelopathies, which, in its more stringent definition, encloses monogenic disorders due to mutations in ion channel genes, has largely contributed to our understanding of the function of the various channel subtypes and of the role of ion channels in multigenic or acquired diseases. Last but not least, ion channels are the main targets of many drugs already used in the clinics. Most of these drugs were introduced in therapy based on the experience acquired quite empirically, and many were discovered afterward to target ion channels. Now, intense research is being conducted to develop new drugs acting selectively on ion channel subtypes and aimed at the understanding of the intimate drug-channel interaction. In this review, we first focus on the pharmacotherapy of ion channel diseases, which includes many drugs targeting ion channels. Then, we describe the molecular pharmacology of ion channels, including the more recent advancement in drug development. Among the newest aspect of ion channel pharmacology, we draw attention to how polymorphisms or mutations in ion channel genes may modify sensitivity to drugs, opening the way toward the development of pharmacogenetics.

  2. Ion Heating in the Martian Ionosphere

    Science.gov (United States)

    Fowler, C. M.; Ergun, R. E.; Andersson, L.; Peterson, W. K.; Hara, T.; Mcfadden, J.; Espley, J.; Halekas, J.; Mitchell, D. L.; Mazelle, C.; Jakosky, B. M.

    2017-10-01

    Energetic O+ and O2+ ions with energies of up to a few hundred eV are observed in the Martian ionosphere. Corresponding ion velocity distributions show ion conics, suggesting that the observed ion populations have been heated perpendicular to the local magnetic field before experiencing a magnetic mirror force. Magnetic field observations support these interpretations: wave power at the local O+ and O2+ gyrofrequencies in the spacecraft frame is observed coincident with the energetic ions, within an apparent magnetic field bottle-like topology. Analysis of the observed ion conics leads to estimates of ion temperatures of 10-30 eV. We suggest that the ion populations are initially heated perpendicular to the local magnetic field by wave power propagating inward from the Mars-solar wind interaction. The local magnetic field "balloons out" in response to these enhanced ion temperatures and pressures. The resultant magnetic field topology is bottle like; the transversely heated ions would subsequently experience a magnetic mirror force in the converging field regions, agreeing with the reported observations. Such strong heating events that significantly increase the ion temperature and pressure, thereby decreasing the net magnetic field, are rare and seem to occur under specific interplanetary magnetic field orientations. Events were observed to span the upper exobase region and just above, a region characterized by significant ion densities in an increasingly collisionless domain. Ion heating in this region has the potential to drive significant ion outflows, thus contributing to atmospheric loss from the planet.

  3. Understanding Molecular Ion-Neutral Atom Collisions for the Production of Ultracold Molecular Ions

    Science.gov (United States)

    2016-06-06

    Understanding Molecular Ion-Neutral Atom Collisions for the Production of Utracold Molecular Ions In the last five years, the study of ultracold...U.S. Army Research Office P.O. Box 12211 Research Triangle Park, NC 27709-2211 molecular ion, quantum chemistry, atom ion interaction...Molecular Ion-Neutral Atom Collisions for the Production of Utracold Molecular Ions Report Title In the last five years, the study of ultracold molecular

  4. Clotrimazole-triiodide ion association as an ion exchanger for a triiodide ion-selective electrode.

    Science.gov (United States)

    Farhadi, Khalil; Maleki, Ramin

    2002-02-01

    A novel triiodide ion-selective electrode based on a clotrimazole-triiodide ion pair as a membrane carrier was prepared. It has a linear response to triiodide from 8 x 10(-6) to 5 x 10(-3) M with a slope of -68.9 mV per decade and a detection limit of 5 x 10(-6) M. The electrode response is independent of the pH of the solution in the pH range 2-9. It has a very short response time and can be used for at least 3 months without any considerable divergence in the potentials. The proposed sensor revealed very good selectivities for I3- over a variety of other anions. It was used as an indicator electrode in the potentiometric titration of triiodide ions and in an indirect potentiometric determination of clotrimazole in pharmaceutical preparations.

  5. A fast beam-ion instability

    Energy Technology Data Exchange (ETDEWEB)

    Stupakov, G.V. [Stanford Linear Accelerator Center, Menlo Park, CA (United States)

    1996-08-01

    The ionization of residual gas by an electron beam in an accelerator generates ions that can resonantly couple to the beam through a wave propagating in the beam-ion system. Results of the study of a beam-ion instability are presented for a multi-bunch train taking into account the decoherence of ion oscillations due to the ion frequency spread and spatial variation of the ion frequency. It is shown that the combination of both effects can substantially reduce the growth rate of the instability. (author)

  6. Ion mobility spectrometer with virtual aperture grid

    Science.gov (United States)

    Pfeifer, Kent B.; Rumpf, Arthur N.

    2010-11-23

    An ion mobility spectrometer does not require a physical aperture grid to prevent premature ion detector response. The last electrodes adjacent to the ion collector (typically the last four or five) have an electrode pitch that is less than the width of the ion swarm and each of the adjacent electrodes is connected to a source of free charge, thereby providing a virtual aperture grid at the end of the drift region that shields the ion collector from the mirror current of the approaching ion swarm. The virtual aperture grid is less complex in assembly and function and is less sensitive to vibrations than the physical aperture grid.

  7. ADVANCED TECHNOLOGY WASTEWATER TREATMENT OF NITRITE IONS

    Directory of Open Access Journals (Sweden)

    E.G. Morozov

    2012-06-01

    Full Text Available The main reason for high concentration of nitrite ions in water is the existence of sources of industrial and agricultural pollution. Contamination of drinking water, juices, wine and other liquids of nitrite ions as a result of improper use of nitrogen fertilizers has an adverse effect on living organism, because under the influence of enzymes nitrite ions in living organisms form high carcinogenic nitrosamines, and the interaction of nitrite ions from blood hemoglobin causes such toxicity that leads to disease cyanosis [1]. Therefore removal of nitrite ions from water has received increased attention. The paper discusses an innovative wastewater treatment technology from the nitrite ion with hypochlorite produced during electrolysis.

  8. Infrared spectroscopy of weakly bound molecular ions

    Energy Technology Data Exchange (ETDEWEB)

    Yeh, Lisa I-Ching

    1988-11-01

    The infrared spectra of a series of hydrated hydronium cluster ions and of protonated ethane ion are presented. A tandem mass spectrometer is ideally suited to obtaining the spectra of such weakly bound molecular ions. Traditional absorption spectroscopy is not feasible in these situations, so the techniques described in this thesis make use of some consequence of photon absorption with higher sensitivity than simply attenuation of laser power. That consequence is dissociation. By first mass selecting the parent ion under study and then mass selecting the fragment ion formed from dissociation, the near unit detection efficiency of ion counting methods has been used to full advantage.

  9. Microfluidic ion-sensing devices.

    Science.gov (United States)

    Johnson, R Daniel; Gavalas, Vasilis G; Daunert, Sylvia; Bachas, Leonidas G

    2008-04-14

    Quantitative determinations of ions in a variety of media have been performed traditionally via one of three approaches: optical instrumental methods (e.g., atomic absorption, and inductively-coupled plasma-optical emission or mass spectrometry), "wet" methods, or ion-selective sensors. Each of the approaches, though, possesses limitations including: power/reagent consumption and lack of portability for instrumental techniques; laborious sample-treatment steps for wet methods; and lack of selectivity and sensitivity with sensors when employed with complex samples. Microfluidic device have emerged as a solution to some of these challenges associated with ion analysis. Such systems can integrate multiple sample handling, calibration, and detection steps ("lab-on-a-chip" concept) into a footprint amenable to portability, while requiring small amounts of sample and power. Furthermore, devices can be constructed for multi-analyte detection, either through multiple parallel fluidic architectures or by using arrays of detection elements. This paper reviews recent progress in the development of total-analysis systems for ionic species. Fabrication techniques and various fluid-handling operations are discussed briefly, followed by a number of more mature strategies for microfluidic ion analysis. A variety of approaches expected to comprise the next generation of devices are also presented.

  10. Microfluidic ion-sensing devices

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, R. Daniel [Department of Chemistry, Murray State University, Murray, KY 42071-3346 (United States)], E-mail: daniel.johnson@murraystate.edu; Gavalas, Vasilis G.; Daunert, Sylvia [Department of Chemistry, University of Kentucky, Lexington, KY 40506-0055 (United States); Bachas, Leonidas G. [Department of Chemistry, University of Kentucky, Lexington, KY 40506-0055 (United States)], E-mail: bachas@uky.edu

    2008-04-14

    Quantitative determinations of ions in a variety of media have been performed traditionally via one of three approaches: optical instrumental methods (e.g., atomic absorption, and inductively-coupled plasma-optical emission or mass spectrometry), 'wet' methods, or ion-selective sensors. Each of the approaches, though, possesses limitations including: power/reagent consumption and lack of portability for instrumental techniques; laborious sample-treatment steps for wet methods; and lack of selectivity and sensitivity with sensors when employed with complex samples. Microfluidic device have emerged as a solution to some of these challenges associated with ion analysis. Such systems can integrate multiple sample handling, calibration, and detection steps ('lab-on-a-chip' concept) into a footprint amenable to portability, while requiring small amounts of sample and power. Furthermore, devices can be constructed for multi-analyte detection, either through multiple parallel fluidic architectures or by using arrays of detection elements. This paper reviews recent progress in the development of total-analysis systems for ionic species. Fabrication techniques and various fluid-handling operations are discussed briefly, followed by a number of more mature strategies for microfluidic ion analysis. A variety of approaches expected to comprise the next generation of devices are also presented.

  11. Improved Ion-Channel Biosensors

    Science.gov (United States)

    Nadeau, Jay; White, Victor; Dougherty, Dennis; Maurer, Joshua

    2004-01-01

    An effort is underway to develop improved biosensors of a type based on ion channels in biomimetic membranes. These sensors are microfabricated from silicon and other materials compatible with silicon. As described, these sensors offer a number of advantages over prior sensors of this type.

  12. Future relativistic heavy ion experiments

    Energy Technology Data Exchange (ETDEWEB)

    Pugh, H.G.

    1980-12-01

    Equations of state for nuclear matter and ongoing experimental studies are discussed. Relativistic heavy ion physics is the only opportunity to study in the laboratory the properties of extended multiquark systems under conditions such that quarks might run together into new arrangements previously unobserved. Several lines of further study are mentioned. (GHT)

  13. Doped to Rare Earth Ions

    African Journals Online (AJOL)

    In the present work, we are interested by studying the spectroscopic properties for optical applications, mainly laser amplification, of MF2 crystals, where M is an alkaline earth (Ba, Sr) or Cadmium (Cd) doped with rare earth ions (Tb3+, Er3+, Ho3+. So far, we present the absorption and emission properties and also the ...

  14. Quantum Games in ion traps

    Energy Technology Data Exchange (ETDEWEB)

    Buluta, Iulia Maria [Department of Quantum Engineering and Systems Science, University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656 (Japan)]. E-mail: noa@lyman.q.t.u-tokyo.ac.jp; Fujiwara, Shingo [Department of Quantum Engineering and Systems Science, University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656 (Japan)]. E-mail: fujiwara@lyman.q.t.u-tokyo.ac.jp; Hasegawa, Shuichi [Department of Quantum Engineering and Systems Science, University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656 (Japan)]. E-mail: hasegawa@q.t.u-tokyo.ac.jp

    2006-10-09

    We propose a general, scalable framework for implementing two-choices-multiplayer Quantum Games in ion traps. In particular, we discuss two famous examples: the Quantum Prisoners' Dilemma and the Quantum Minority Game. An analysis of decoherence due to intensity fluctuations in the applied laser fields is also provided.

  15. Ion Channels in Brain Metastasis.

    Science.gov (United States)

    Klumpp, Lukas; Sezgin, Efe C; Eckert, Franziska; Huber, Stephan M

    2016-09-08

    Breast cancer, lung cancer and melanoma exhibit a high metastatic tropism to the brain. Development of brain metastases severely worsens the prognosis of cancer patients and constrains curative treatment options. Metastasizing to the brain by cancer cells can be dissected in consecutive processes including epithelial-mesenchymal transition, evasion from the primary tumor, intravasation and circulation in the blood, extravasation across the blood-brain barrier, formation of metastatic niches, and colonization in the brain. Ion channels have been demonstrated to be aberrantly expressed in tumor cells where they regulate neoplastic transformation, malignant progression or therapy resistance. Moreover, many ion channel modulators are FDA-approved drugs and in clinical use proposing ion channels as druggable targets for future anti-cancer therapy. The present review article aims to summarize the current knowledge on the function of ion channels in the different processes of brain metastasis. The data suggest that certain channel types involving voltage-gated sodium channels, ATP-release channels, ionotropic neurotransmitter receptors and gap junction-generating connexins interfere with distinct processes of brain metastazation.

  16. Ion Channels in Brain Metastasis

    Directory of Open Access Journals (Sweden)

    Lukas Klumpp

    2016-09-01

    Full Text Available Breast cancer, lung cancer and melanoma exhibit a high metastatic tropism to the brain. Development of brain metastases severely worsens the prognosis of cancer patients and constrains curative treatment options. Metastasizing to the brain by cancer cells can be dissected in consecutive processes including epithelial–mesenchymal transition, evasion from the primary tumor, intravasation and circulation in the blood, extravasation across the blood–brain barrier, formation of metastatic niches, and colonization in the brain. Ion channels have been demonstrated to be aberrantly expressed in tumor cells where they regulate neoplastic transformation, malignant progression or therapy resistance. Moreover, many ion channel modulators are FDA-approved drugs and in clinical use proposing ion channels as druggable targets for future anti-cancer therapy. The present review article aims to summarize the current knowledge on the function of ion channels in the different processes of brain metastasis. The data suggest that certain channel types involving voltage-gated sodium channels, ATP-release channels, ionotropic neurotransmitter receptors and gap junction-generating connexins interfere with distinct processes of brain metastazation.

  17. Terbium doped SnO2 nanoparticles as white emitters and SnO2:5Tb/Fe3O4 magnetic luminescent nanohybrids for hyperthermia application and biocompatibility with HeLa cancer cells.

    Science.gov (United States)

    Singh, Laishram Priyobarta; Singh, Ningthoujam Premananda; Srivastava, Sri Krishna

    2015-04-14

    SnO2:5Tb (SnO2 doped with 5 at% Tb(3+)) nanoparticles were synthesised by a polyol method and their luminescence properties at different annealing temperatures were studied. Characterization of nanomaterials was done by X-ray diffraction (XRD), Fourier transformation infrared spectroscopy (FTIR), transmission electron microscopy (TEM) and vibrating sample magnetometry (VSM). XRD studies indicate that the prepared nanoparticles were of tetragonal structures. Upon Tb(3+) ion incorporation into SnO2, Sn(4+) changes to Sn(2+) and, on annealing again at higher temperature, Sn(2+) changes to Sn(4+). The prepared nanoparticles were spherical in shape. Sn-O vibrations were found from the FTIR studies. In photoluminescence studies, the intensity of the emission peaks of Tb(3+) ions increases with the increase of annealing temperature, and emission spectra lie in the region of white emission in the CIE diagram. CCT calculations show that the SnO2:5Tb emission lies in cold white emission. Quantum yields up to 38% can be obtained for 900 °C annealed samples. SnO2:5Tb nanoparticles were well incorporated into the PVA polymer and such a material incorporated into the polymer can be used for display devices. The SnO2:5Tb/Fe3O4 nanohybrid was prepared and investigated for hyperthermia applications at different concentrations of the nanohybrid. This achieves a hyperthermia temperature (42 °C) under an AC magnetic field. The hybrid nanomaterial SnO2:5Tb/Fe3O4 was found to exhibit biocompatibility with HeLa cells (human cervical cancer cells) at concentrations up to 74% for 100 μg L(-1). Also, this nanohybrid shows green emission and thus it will be helpful in tracing magnetic nanoparticles through optical imaging in vivo and in vitro application.

  18. Studies of the hydroxyborohydride and triborohydride ions

    Energy Technology Data Exchange (ETDEWEB)

    Reed, J.

    1977-10-01

    Results of the following studies are reported: chemical synthesis of hydroxytrihydroborate and peroxynitrite; the reduction of organic compounds with the hydroxyborohydride ion; and a kinetic study of the hydrolysis of the octahydrotriborate ions. (LK)

  19. Scaling ion traps for quantum computing

    CSIR Research Space (South Africa)

    Uys, H

    2010-09-01

    Full Text Available The design, fabrication and preliminary testing of a chipscale, multi-zone, surface electrode ion trap is reported. The modular design and fabrication techniques used are anticipated to advance scalability of ion trap quantum computing architectures...

  20. Divergent Field Annular Ion Engine Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposed work investigates an approach that would allow an annular ion engine geometry to achieve ion beam currents approaching the Child-Langmuir limit. In this...

  1. Additive Manufacturing of Ion Thruster Optics Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Plasma Controls will manufacture and test a set of ion optics for electric propulsion ion thrusters using additive manufacturing technology, also known as 3D...

  2. Metal ions, Alzheimer's disease and chelation therapy

    National Research Council Canada - National Science Library

    Budimir, Ana

    2011-01-01

    .... In contrast to the direct chelation approach in metal ion overload disorders, in neurodegeneration the goal seems to be a better and subtle modulation of metal ion homeostasis, aimed at restoring ionic balance...

  3. Lithium-Ion Battery Program Status

    Science.gov (United States)

    Surampudi, S.; Huang, C. K.; Smart, M.; Davies, E.; Perrone, D.; Distefano, S.; Halpert, G.

    1996-01-01

    The objective of this program is to develop rechargeable Li-ion cells for future NASA missions. Applications that would benefit from this project are: new millenium spacecraft; rovers; landers; astronaut equipment; and planetary orbiters. The approach of this program is: select electrode materials and electrolytes; identify failure modes and mechanisms and enhance cycle life; demonstrate Li-ion cell technology with liquid electrolyte; select candidate polymer electrolytes for Li-ion polymer cells; and develop Li-ion polymer cell technology.

  4. From heavy ions to exotic atoms

    OpenAIRE

    Indelicato, Paul; Trassinelli, Martino

    2005-01-01

    We review a number of experiments and theoretical calculations on heavy ions and exotic atoms, which aim at providing informations on fundamental interactions. Among those are propositions of experiments for parity violation measurements in heavy ions and high-precision mesurements of He-like transition energies in highly charged ions. We also describe recent experiments on pionic atoms, that make use of highly-charged ion transitions to obtain accurate measurements of strong interaction shif...

  5. Ion-batterier - "The Next Generation"

    DEFF Research Database (Denmark)

    Søndergaard, Martin; Becker, Jacob; Shen, Yanbin

    2014-01-01

    Lithium-ion batterier er strømkilden, der har revolutioneret vores transportable elektronik. Familien af ion-batterier er imidlertid større end som så og har meget, meget mere at byde på.......Lithium-ion batterier er strømkilden, der har revolutioneret vores transportable elektronik. Familien af ion-batterier er imidlertid større end som så og har meget, meget mere at byde på....

  6. Negative ions produced in multicharged ions and C60 collisions

    Science.gov (United States)

    Martin, S.; Salmoun, A.; Brédy, R.; Montagne, G.; Bernard, J.; Ma, X.; Chen, L.

    2011-06-01

    We have measured the differential cross-sections in F3+-C60 collisions at low velocity (v=0.18 a.u.). Using coincidence measurements between the ejected electron number and recoil ions, we have estimated the initial charge state of C60 parent ions associated with neutral outgoing projectiles to range from 4+ to 7+. We found that the formation of anions is correlated with the strong excitation of C60 (average excitation energy about 160 eV). The cross-section of the production of the anion has been found to be 25 a.u. This value is in agreement with the scenario of anion formation in two steps. In the first step, F3+ ions are neutralized by multicollision on the C60 surface. In the second step and at the exit part of the collision, the electron attachment process occurs. For the production of a stable anion, the capture of electrons on carbon must occur directly to the ground states of F-, giving many electron vacancies on C60. This process explains the observation of strong electronic and vibronic excitations of C60 leading to electron emission and multifragmentation processes.

  7. Ion-optically driven depth compensation for ion beam tracking

    Energy Technology Data Exchange (ETDEWEB)

    Chaudhri, Naved; Saito, Nami; Bert, Christoph; Franczak, Bernhard; Durante, Marco; Schardt, Dieter [GSI, Abt. Biophysik, Darmstadt (Germany); Rietzel, Eike [Siemens Healthcare, Particle Therapy, Erlangen (Germany)

    2009-07-01

    The beam delivery system for scanned carbon ion beam radiotherapy at GSI has been extended in research mode to irradiate moving targets. For beam tracking, the ion beam is adapted laterally as well as in range corresponding to the target's three dimensional (3D) motion. A beam tracking system with a motorized double wedge system for fast and accurate range adaptation has been developed. In addition to the current range adaptation system a much faster method for online energy modulation is being investigated where a fine focused ion beam is dynamically positioned, controlled by fast dipole magnets, on a small static wedge shaped absorber within the beam line. Experiments were performed at the therapy beam line to study the beam shift from central axis by the first dipole magnet up to the maximum limit where the beam can be deflected back to central axis by the second dipole magnet. Beam profiles were measured at different locations of the beam delivery system. The particle transmission was measured as well at the target position. Experiments were supported by Monte Carlo simulations for energy variation studies and for assessing the influence on beam profiles using MOCADI code.

  8. On ion escape from Venus

    Science.gov (United States)

    Jarvinen, R.

    2011-04-01

    This doctoral thesis is about the solar wind influence on the atmosphere of the planet Venus. A numerical plasma simulation model was developed for the interaction between Venus and the solar wind to study the erosion of charged particles from the Venus upper atmosphere. The developed model is a hybrid simulation where ions are treated as particles and electrons are modelled as a fluid. The simulation was used to study the solar wind induced ion escape from Venus as observed by the European Space Agency's Venus Express and NASA's Pioneer Venus Orbiter spacecraft. Especially, observations made by the ASPERA-4 particle instrument onboard Venus Express were studied. The thesis consists of an introductory part and four peer-reviewed articles published in scientific journals. In the introduction Venus is presented as one of the terrestrial planets in the Solar System and the main findings of the work are discussed within the wider context of planetary physics.Venus is the closest neighbouring planet to the Earth and the most earthlike planet in its size and mass orbiting the Sun. Whereas the atmosphere of the Earth consists mainly of nitrogen and oxygen, Venus has a hot carbon dioxide atmosphere, which is dominated by the greenhouse effect. Venus has all of its water in the atmosphere, which is only a fraction of the Earth's total water supply. Since planets developed presumably in similar conditions in the young Solar System, why Venus and Earth became so different in many respects?One important feature of Venus is that the planet does not have an intrinsic magnetic field. This makes it possible for the solar wind, a continuous stream of charged particles from the Sun, to flow close to Venus and to pick up ions from the planet's upper atmosphere. The strong intrinsic magnetic field of the Earth dominates the terrestrial magnetosphere and deflects the solar wind flow far away from the atmosphere. The region around Venus where the planet's atmosphere interacts with the

  9. Ion-exchange chromatographic protein refolding

    NARCIS (Netherlands)

    Freydell, E.; Wielen, van der L.; Eppink, M.H.M.; Ottens, M.

    2010-01-01

    The application of ion-exchange (IEX) chromatography to protein refolding (IExR) has been successfully proven, as supported by various studies using different model proteins, ion-exchange media and flow configurations. Ion-exchange refolding offers a relatively high degree of process

  10. Superconducting heavy-ion accelerating structures

    Energy Technology Data Exchange (ETDEWEB)

    Shepard, K.W.

    1996-08-01

    This paper briefly reviews the technical history of superconducting ion-accelerating structures. Various superconducting cavities currently used and being developed for use in ion linacs are discussed. Principal parameters and operational characteristics of superconducting structures in active use at various heavy-ion facilities are described.

  11. Drift wave in pair-ion plasma

    Indian Academy of Sciences (India)

    ion plasma are discussed. It is shown that the temperature and/or mass difference of both species could produce drift wave in a pair-ion plasma. The results are discussed in the context of the fullerene pair-ion plasma experiment.

  12. Trapping and Sympathetic Cooling of Boron Ions

    CERN Document Server

    Rugango, Rene; Shu, Gang; Brown, Kenneth R

    2016-01-01

    We demonstrate the trapping and sympathetic cooling of B$^{+}$ ions in a Coulomb crystal of laser-cooled Ca$^{+}$, We non-destructively confirm the presence of the both B$^+$ isotopes by resonant excitation of the secular motion. The B$^{+}$ ions are loaded by ablation of boron and the secular excitation spectrum also reveals features consistent with ions of the form B$_{n}^{+}$.

  13. Nanofabrication with a helium ion microscope

    NARCIS (Netherlands)

    Maas, D.; Van Veldhoven, E.; Chen, P.; Sidorkin, V.; Salemink, H.; Van der Drift, E.; Alkemade, P.

    2009-01-01

    The recently introduced helium ion microscope (HIM) is capable of imaging and fabrication of nanostructures thanks to its sub-nanometer sized ion probe [1,2]. The unique interaction of the helium ions with the sample material provides very localized secondary electron emission, thus providing a

  14. Ion heat transport studies in JET

    DEFF Research Database (Denmark)

    Mantica, P; Angioni, C; Baiocchi, B

    2011-01-01

    Detailed experimental studies of ion heat transport have been carried out in JET exploiting the upgrade of active charge exchange spectroscopy and the availability of multi-frequency ion cyclotron resonance heating with 3He minority. The determination of ion temperature gradient (ITG) threshold a...

  15. Negative Halogen Ions for Fusion Applications

    Energy Technology Data Exchange (ETDEWEB)

    Grisham, L.R.; Kwan, J.W.; Hahto, S.K.; Hahto, S.T.; Leung, K.N.; Westenskow, G.

    2006-01-01

    Over the past quarter century, advances in hydrogen negative ion sources have extended the usable range of hydrogen isotope neutral beams to energies suitable for large magnetically confined fusion devices. Recently, drawing upon this experience, negative halogen ions have been proposed as an alternative to positive ions for heavy ion fusion drivers in inertial confinement fusion, because electron accumulation would be prevented in negative ion beams, and if desired, the beams could be photo-detached to neutrals. This paper reports the results of an experiment comparing the current density and beam emittance of Cl+ and Cl- extracted from substantially ion-ion plasmas with that of Ar+ extracted from an ordinary electron-ion plasma, all using the same source, extractor, and emittance scanner. At similar discharge conditions, the Cl- current was typically 85 – 90% of the positive chlorine current, with an e-/ Cl- ratio as low as seven without grid magnets. The Cl- was as much as 76% of the Ar+ current from a discharge with the same RF drive. The minimum normalized beam emittance and inferred ion temperatures of Cl+, Cl-, and Ar+ were all similar, so the current density and optical quality of Cl- appear as suitable for heavy ion fusion driver applications as a positive noble gas ion of similar mass. Since F, I, and Br should all behave similarly in an ion source, they should also be suitable as driver beams.

  16. The mean excitation energy of atomic ions

    DEFF Research Database (Denmark)

    Sauer, Stephan P. A.; Oddershede, Jens; Sabin, John R.

    2015-01-01

    A method for calculation of the mean excitation energies of atomic ions is presented, making the calculation of the energy deposition of fast ions to plasmas, warm, dense matter, and complex biological systems possible. Results are reported to all ions of helium, lithium, carbon, neon, aluminum, ...

  17. Improved Ion Optics for Introduction of Ions into a 9.4 Tesla Fourier Transform Ion Cyclotron Resonance Mass Spectrometer

    Science.gov (United States)

    Chen, Yu; Leach, Franklin E.; Kaiser, Nathan K.; Dang, Xibei; Ibrahim, Yehia M.; Norheim, Randolph V.; Anderson, Gordon A.; Smith, Richard D.; Marshall, Alan G.

    2014-01-01

    Enhancements to the ion source and transfer optics of our 9.4 T FT-ICR mass spectrometer have resulted in improved ion transmission efficiency for more sensitive mass measurement of complex mixtures at the MS and MS/MS levels. The tube lens/skimmer has been replaced by a dual ion funnel and the following octopole by a quadrupole for reduced ion cloud radial expansion before transmission into a mass-selective quadrupole. The number of ions that reach the ICR cell is increased by an order of magnitude for the funnel/quadrupole relative to the tube lens/skimmer/octopole. PMID:25601704

  18. Na Cl-ion pair association in water-DMSO mixtures: Effect of ion pair ...

    Indian Academy of Sciences (India)

    The physical picturethat emerges is that there is a strong contact ion pair (CIP) and strong to moderate solvent separated ion pair(SSIP) in these solutions. Analysis of local ion clusters shows that ions are dominantly solvated by watermolecules. The 12-6-1 potential model predicts running coordination numbers closest to ...

  19. Na Cl ion pair association in water-DMSO mixtures: Effect of ion pair ...

    Indian Academy of Sciences (India)

    ion pair in water–dimethyl sulfoxide (DMSO) mixtures for three DMSO mole fractions have been computed using constrained Molecular Dynamics (MD) simulations and confirmed by dynamical trajectories and residence times of the ion pair at various inter-ionic separations. The three ion-ion direct potentials used are 12-6-1 ...

  20. Heavy Ion Injection Into Synchrotrons, Based On Electron String Ion Sources

    CERN Document Server

    Donets, E E; Syresin, E M

    2004-01-01

    A possibility of heavy ions injection into synchrotrons is discussed on the base of two novel ion sources, which are under development JINR during last decade: 1) the electron string ion source (ESIS), which is a modified version of a conventional electron beam ion source (EBIS), working in a reflex mode of operation, and 2) the tubular electron string ion source (TESIS). The Electron String Ion Source "Krion-2" (VBLHE, JINR, Dubna) with an applied confining magnetic field of 3 T was used for injection into the superconducting JINR synchrotron - Nuclotron and during this runs the source provided a high pulse intensity of the highly charged ion beams: Ar16+

  1. Rechargeable Aluminum-Ion Batteries

    Energy Technology Data Exchange (ETDEWEB)

    Paranthaman, Mariappan Parans [ORNL; Liu, Hansan [ORNL; Sun, Xiao-Guang [ORNL; Dai, Sheng [ORNL; Brown, Gilbert M [ORNL

    2015-01-01

    This chapter reports on the development of rechargeable aluminum-ion batteries. A possible concept of rechargeable aluminum/aluminum-ion battery based on low-cost, earth-abundant Al anode, ionic liquid EMImCl:AlCl3 (1-ethyl-3-methyl imidazolium chloroaluminate) electrolytes and MnO2 cathode has been proposed. Al anode has been reported to show good reversibility in acid melts. However, due to the problems in demonstrating the reversibility in cathodes, alternate battery cathodes and battery concepts have also been presented. New ionic liquid electrolytes for reversible Al dissolution and deposition are needed in the future for replacing corrosive EMImCl:AlCl3 electrolytes.

  2. Ion channelopathies and migraine pathogenesis.

    Science.gov (United States)

    Albury, Cassie L; Stuart, Shani; Haupt, Larisa M; Griffiths, Lyn R

    2017-08-01

    Migraine is a common neurological disorder that affects approximately 12-20% of the general adult population. Migraine pathogenesis is complex and not wholly understood. Molecular genetic investigations, imaging and biochemical studies, have unveiled a number of interconnected neurological pathways which seem to have a cause and effect component integral to its cause. Much weight of migraine attack initiation can be placed on the initial trigger and the pathways involved in its neuronal counter reaction. Ion channels play a large role in the generation, portrayal and mitigation of the brains response to external triggers. Several genetic studies have identified and implicated a number of ion channelopathy genes which may contribute to this generalised process. This review will focus on the genetics of migraine with particular emphasis placed on the potentially important role genes HEPH (responsible for iron transport and homeostasis) and KCNK18 (important for the transport and homeostasis of potassium) play in migraine cause.

  3. Semiholography for heavy ion collisions

    CERN Document Server

    Mukhopadhyay, Ayan

    2017-01-01

    The formation of QGP in heavy ion collisions gives us a great opportunity for learning about nonperturbative dynamics of QCD. Semiholography provides a new consistent framework to combine perturbative and non-perturbative effects in a coherent way and can be applied to obtain an effective description for heavy ion collisions. In particular, it allows us to include nonperturbative effects in existing glasma effective theory and QCD kinetic theory for the weakly coupled saturated degrees of freedom liberated by the collisions in the initial stages in a consistent manner. We argue why the full framework should be able to confront experiments with only a few phenomenological parameters and present feasibility tests for the necessary numerical computations. Furthermore, we discuss that semiholography leads to a new description of collective flow in the form of a generalised non-Newtonian fluid. We discuss some open questions which we hope to answer in the near future.

  4. Perspective on the Role of Negative Ions and Ion-Ion Plasmas in Heavy Ion Fusion Science, Magnetic Fusion Energy, and Related Fields

    Energy Technology Data Exchange (ETDEWEB)

    L. Grisham and J.W. Kwan

    2008-08-12

    Some years ago it was suggested that halogen negative ions [1] could offer a feasible alternative path to positive ions as a heavy ion fusion driver beam which would not suffer degradation due to electron accumulation in the accelerator and beam transport system, and which could be converted to a neutral beam by photodetachment near the chamber entrance if desired. Since then, experiments have demonstrated that negative halogen beams can be extracted and accelerated away from the gas plume near the source with a surviving current density close to what could be achieved with a positive ion of similar mass, and with comparable optical quality. In demonstrating the feasibility of halogen negative ions as heavy ion driver beams, ion - ion plasmas, an interesting and somewhat novel state of matter, were produced. These plasmas, produced near the extractor plane of the sources, appear, based upon many lines of experimental evidence, to consist of almost equal densities of positive and negative chlorine ions, with only a small component of free electrons. Serendipitously, the need to extract beams from this plasma for driver development provides a unique diagnostic tool to investigate the plasma, since each component - positive ions, negative ions, and electrons -- can be extracted and measured separately. We discuss the relevance of these observations to understanding negative ion beam extraction from electronegative plasmas such as halogens, or the more familiar hydrogen of magnetic fusion ion sources. We suggest a concept which might improve negative hydrogen extraction by the addition of a halogen. The possibility and challenges of producing ion-ion plasmas with thin targets of halogens or, perhaps, salt, is briefly addressed.

  5. Perspective on the Role of Negative Ions and Ion-Ion Plasmas in Heavy Ion Fusion Science, Magnetic Fusion Energy,and Related Fields

    Energy Technology Data Exchange (ETDEWEB)

    Grisham, L. R.; Kwan, J. W.

    2008-08-01

    Some years ago it was suggested that halogen negative ions could offer a feasible alternative path to positive ions as a heavy ion fusion driver beam which would not suffer degradation due to electron accumulation in the accelerator and beam transport system, and which could be converted to a neutral beam by photodetachment near the chamber entrance if desired. Since then, experiments have demonstrated that negative halogen beams can be extracted and accelerated away from the gas plume near the source with a surviving current density close to what could be achieved with a positive ion of similar mass, and with comparable optical quality. In demonstrating the feasibility of halogen negative ions as heavy ion driver beams, ion - ion plasmas, an interesting and somewhat novel state of matter, were produced. These plasmas, produced near the extractor plane of the sources, appear, based upon many lines of experimental evidence, to consist of almost equal densities of positive and negative chlorine ions, with only a small component of free electrons. Serendipitously, the need to extract beams from this plasma for driver development provides a unique diagnostic tool to investigate the plasma, since each component - positive ions, negative ions, and electrons - can be extracted and measured separately. We discuss the relevance of these observations to understanding negative ion beam extraction from electronegative plasmas such as halogens, or the more familiar hydrogen of magnetic fusion ion sources. We suggest a concept which might improve negative hydrogen extraction by the addition of a halogen. The possibility and challenges of producing ion - ion plasmas with thin targets of halogens or, perhaps, salt, is briefly addressed.

  6. Perspective on the Role of Negative Ions and Ion-Ion Plasmas in Heavy Ion Fusion Science, Magnetic Fusion Energy, and Related Fields

    Energy Technology Data Exchange (ETDEWEB)

    Grisham, L.R.; Kwan, J.W.

    2008-08-01

    Some years ago it was suggested that halogen negative ions [1]could offer a feasible alternative path to positive ions as a heavy ion fusion driver beam which would not suffer degradation due to electron accumulation in the accelerator and beam transport system, and which could be converted to a neutral beam by photodetachment near the chamber entrance if desired. Since then, experiments have demonstrated that negative halogen beams can be extracted and accelerated away from the gas plume near the source with a surviving current density close to what could be achieved with a positive ion of similar mass, and with comparable optical quality. In demonstrating the feasibility of halogen negative ions as heavy ion driver beams, ion - ion plasmas, an interesting and somewhat novel state of matter, were produced. These plasmas, produced near the extractor plane of the sources, appear, based upon many lines of experimental evidence, to consist of almost equal densities of positive and negative chlorine ions, with only a small component of free electrons. Serendipitously, the need to extract beams from this plasma for driver development provides a unique diagnostic tool to investigate the plasma, since each component - positive ions, negative ions, and electrons -- can be extracted and measured separately. We discuss the relevance of these observations to understanding negative ion beam extraction from electronegative plasmas such as halogens, or the more familiar hydrogen of magnetic fusion ion sources. We suggest a concept which might improve negative hydrogen extraction by the addition of a halogen. The possibility and challenges of producing ion-ion plasmas with thin targets of halogens or, perhaps, salt, is briefly addressed.

  7. Electrically controlled cesium ion exchange

    Energy Technology Data Exchange (ETDEWEB)

    Lilga, M. [Pacific Northwest Lab., Richland, WA (United States)

    1996-10-01

    Several sites within the DOE complex (Savannah River, Idaho, Oak Ridge and Hanford) have underground storage tanks containing high-level waste resulting from nuclear engineering activities. To facilitate final disposal of the tank waste, it is advantageous to separate and concentrate the radionuclides for final immobilization in a vitrified glass matrix. This task proposes a new approach for radionuclide separation by combining ion exchange (IX) and electrochemistry to provide a selective and economic separation method.

  8. Chromosome Aberrations by Heavy Ions

    Science.gov (United States)

    Ballarini, Francesca; Ottolenghi, Andrea

    It is well known that mammalian cells exposed to ionizing radiation can show different types of chromosome aberrations (CAs) including dicentrics, translocations, rings, deletions and complex exchanges. Chromosome aberrations are a particularly relevant endpoint in radiobiology, because they play a fundamental role in the pathways leading either to cell death, or to cell conversion to malignancy. In particular, reciprocal translocations involving pairs of specific genes are strongly correlated (and probably also causally-related) with specific tumour types; a typical example is the BCR-ABL translocation for Chronic Myeloid Leukaemia. Furthermore, aberrations can be used for applications in biodosimetry and more generally as biomarkers of exposure and risk, that is the case for cancer patients monitored during Carbon-ion therapy and astronauts exposed to space radiation. Indeed hadron therapy and astronauts' exposure to space radiation represent two of the few scenarios where human beings can be exposed to heavy ions. After a brief introduction on the main general features of chromosome aberrations, in this work we will address key aspects of the current knowledge on chromosome aberration induction, both from an experimental and from a theoretical point of view. More specifically, in vitro data will be summarized and discussed, outlining important issues such as the role of interphase death/mitotic delay and that of complex-exchange scoring. Some available in vivo data on cancer patients and astronauts will be also reported, together with possible interpretation problems. Finally, two of the few available models of chromosome aberration induction by ionizing radiation (including heavy ions) will be described and compared, focusing on the different assumptions adopted by the authors and on how these models can deal with heavy ions.

  9. Holifield Heavy Ion Research Facility

    Energy Technology Data Exchange (ETDEWEB)

    Jones, C.M.; Alton, G.D.; Ball, J.B.; Biggerstaff, J.A.; Dowling, D.T.; Erb, K.A.; Haynes, D.L.; Hoglund, D.E.; Hudson, E.D.; Juras, R.C.

    1986-02-15

    The Holifield Heavy Ion Research Facility has been in routine operation since July 1982. Beams have been provided using both the tandem accelerator alone and a coupled mode in which the Oak Ridge Isochronous Cyclotron is used as an energy booster for tandem beams. The coupled mode has proved to be especially effective and has allowed us to provide a wide range of energetic beams for scheduled experiments. In this report we discuss our operational experience and recent development activities.

  10. Holifield Heavy Ion Research Facility

    Energy Technology Data Exchange (ETDEWEB)

    Jones, C.M.; Alton, G.D.; Ball, J.B.; Biggerstaff, J.A.; Dowling, D.T.; Erb, K.A.; Haynes, D.L.; Hoglund, D.E.; Hudson, E.D.; Juras, R.C.

    1985-01-01

    The Holifield Heavy Ion Research Facility has been in routine operation since July 1982. Beams have been provided using both the tandem accelerator alone and a coupled mode in which the Oak Ridge Isochronous Cyclotron is used as an energy booster for tandem beams. The coupled mode has proved to be especially effective and has allowed us to provide a wide range of energetic beams for scheduled experiments. In this report we discuss our operational experience and recent development activities.

  11. Optically pumped polarized ion sources

    Energy Technology Data Exchange (ETDEWEB)

    Zelenski, A.N.

    1995-12-31

    Polarization transfer collisions between protons, atomic hydrogen, or deuterium and optically pumped alkali-metal vapour are implemented in the high current optically pumped polarized ion source (OPPIS) and the laser driven source (LDS) of nuclear polarized atoms for target applications. The OPPIS technique overcomes the limitations on intensity of the conventional atomic beam source technique and meets the requirements of the new generation of polarization experiments at multi-GeV accelerators and colliders. 17 refs., 3 figs.

  12. Asymmetric Ion-Pairing Catalysis

    Science.gov (United States)

    Brak, Katrien

    2014-01-01

    Charged intermediates and reagents are ubiquitous in organic transformations. The interaction of these ionic species with chiral neutral, anionic, or cationic small molecules has emerged as a powerful strategy for catalytic, enantioselective synthesis. This review describes developments in the burgeoning field of asymmetric ion-pairing catalysis with an emphasis on the insights that have been gleaned into the structural and mechanistic features that contribute to high asymmetric induction. PMID:23192886

  13. Electrolytes for lithium ion batteries

    Science.gov (United States)

    Vaughey, John; Jansen, Andrew N.; Dees, Dennis W.

    2014-08-05

    A family of electrolytes for use in a lithium ion battery. The genus of electrolytes includes ketone-based solvents, such as, 2,4-dimethyl-3-pentanone; 3,3-dimethyl 2-butanone(pinacolone) and 2-butanone. These solvents can be used in combination with non-Lewis Acid salts, such as Li.sub.2[B.sub.12F.sub.12] and LiBOB.

  14. Heavy-ion Physics (ATLAS)

    CERN Document Server

    Przybycien, Mariusz; The ATLAS collaboration

    2017-01-01

    The ATLAS experiment at the Large Hadron Collider has undertaken a broad physics program to probe and characterize the hot nuclear matter created in relativistic heavy-ion collisions. This talk presents recent results on production of electroweak bosons and quarkonium, charged particles and jets, bulk particle collectivity and electromagnetic processes in ultra-peripheral collisions, from Pb+Pb and p+Pb collisions.

  15. Intracellular ion channels and cancer.

    Science.gov (United States)

    Leanza, Luigi; Biasutto, Lucia; Managò, Antonella; Gulbins, Erich; Zoratti, Mario; Szabò, Ildikò

    2013-09-03

    Several types of channels play a role in the maintenance of ion homeostasis in subcellular organelles including endoplasmatic reticulum, nucleus, lysosome, endosome, and mitochondria. Here we give a brief overview of the contribution of various mitochondrial and other organellar channels to cancer cell proliferation or death. Much attention is focused on channels involved in intracellular calcium signaling and on ion fluxes in the ATP-producing organelle mitochondria. Mitochondrial K(+) channels (Ca(2+)-dependent BKCa and IKCa, ATP-dependent KATP, Kv1.3, two-pore TWIK-related Acid-Sensitive K(+) channel-3 (TASK-3)), Ca(2+) uniporter MCU, Mg(2+)-permeable Mrs2, anion channels (voltage-dependent chloride channel VDAC, intracellular chloride channel CLIC) and the Permeability Transition Pore (MPTP) contribute importantly to the regulation of function in this organelle. Since mitochondria play a central role in apoptosis, modulation of their ion channels by pharmacological means may lead to death of cancer cells. The nuclear potassium channel Kv10.1 and the nuclear chloride channel CLIC4 as well as the endoplasmatic reticulum (ER)-located inositol 1,4,5-trisphosphate (IP3) receptor, the ER-located Ca(2+) depletion sensor STIM1 (stromal interaction molecule 1), a component of the store-operated Ca(2+) channel and the ER-resident TRPM8 are also mentioned. Furthermore, pharmacological tools affecting organellar channels and modulating cancer cell survival are discussed. The channels described in this review are summarized on Figure 1. Overall, the view is emerging that intracellular ion channels may represent a promising target for cancer treatment.

  16. Intracellular ion channels and cancer

    Directory of Open Access Journals (Sweden)

    Luigi eLeanza

    2013-09-01

    Full Text Available Several types of channels play a role in the maintenance of ion homeostasis in subcellular organelles including endoplasmatic reticulum, nucleus, lysosome, endosome and mitochondria. Here we give a brief overview of the contribution of various mitochondrial and other organellar channels to cancer cell proliferation or death. Much attention is focused on channels involved in intracellular calcium signaling and on ion fluxes in the ATP-producing organelle mitochondria. Mitochondrial K+ channels (Ca2+-dependent BKCa and IKCa, ATP-dependent KATP, Kv1.3, two-pore TWIK-related Acid-Sensitive K+ channel-3 (TASK-3, Ca2+ uniporter MCU, Mg2+-permeable Mrs2, anion channels (voltage-dependent chloride channel VDAC, intracellular chloride channel CLIC and the Permeability Transition Pore (MPTP contribute importantly to the regulation of function in this organelle. Since mitochondria play a central role in apoptosis, modulation of their ion channels by pharmacological means may lead to death of cancer cells. The nuclear potassium channel Kv10.1 and the nuclear chloride channel CLIC4 as well as the endoplasmatic reticulum (ER-located inositol 1,4,5-trisphosphate (IP3 receptor, the ER-located Ca2+ depletion sensor STIM1 (stromal interaction molecule 1, a component of the store-operated Ca2+ channel and the ER-resident TRPM8 are also mentioned. Furthermore, pharmacological tools affecting organellar channels and modulating cancer cell survival are discussed. The channels described in this review are summarized on Figure 1. Overall, the view is emerging that intracellular ion channels may represent a promising target for cancer treatment.

  17. Ion-Pumping Microbial Rhodopsins

    Directory of Open Access Journals (Sweden)

    Hideki eKandori

    2015-09-01

    Full Text Available Rhodopsins are light-sensing proteins used in optogenetics. The word rhodopsin originates from the Greek words rhodo and opsis, indicating rose and sight, respectively. Although the classical meaning of rhodopsin is the red-colored pigment in our eyes, the modern meaning of rhodopsin encompasses photoactive proteins containing a retinal chromophore in animals and microbes. Animal and microbial rhodopsins possess 11-cis and all-trans retinal, respectively, to capture light in seven transmembrane α-helices, and photoisomerizations into all-trans and 13-cis forms, respectively, initiate each function. Ion-transporting proteins can be found in microbial rhodopsins, such as light-gated channels and light-driven pumps, which are the main tools in optogenetics. Light-driven pumps, such as archaeal H+ pump bacteriorhodopsin (BR and Cl- pump halorhodopsin (HR, were discovered in the 1970s, and their mechanism has been extensively studied. On the other hand, different kinds of H+ and Cl- pumps have been found in marine bacteria, such as proteorhodopsin (PR and Fulvimarina pelagi rhodopsin (FR, respectively. In addition, a light-driven Na+ pump was found, Krokinobacter eikastus rhodopsin 2 (KR2. These light-driven ion-pumping microbial rhodopsins are classified as DTD, TSA, DTE, NTQ and NDQ rhodopsins for BR, HR, PR, FR and KR2, respectively. Recent understanding of ion-pumping microbial rhodopsins is reviewed in this paper.

  18. heavy ion acceleration at shocks

    Science.gov (United States)

    Shevchenko, V. I.; Galinsky, V.

    2009-12-01

    The theoretical study of alpha particle acceleration at a quasi-parallel shock due to interaction with Alfven waves self-consistently excited in both upstream and downstream regions was conducted using a scale-separation model [1]. The model uses conservation laws and resonance conditions to find where waves will be generated or dumped and hence particles will be pitch--angle scattered as well as the change of the wave energy due to instability or damping. It includes in consideration the total distribution function (the bulk plasma and high energy tail), so no any assumptions (e.g. seed populations, or some ad-hoc escape rate of accelerated particles) are required. In previous studies heavy ions were treated as perfect test particles, they only experienced the Alfven turbulence excited by protons and didn’t contribute to turbulence generation. In contrast to this approach, we consider the ion scattering on hydromagnetic turbulence generated by both protons and ions themselves. It is important for alpha particles with their relatively large mass-loading parameter that defines efficiency of the wave excitation by alpha particles. The energy spectra of alpha particles is found and compared with those obtained in test particle approximation. [1] Galinsky, V.L., and V.I. Shevchenko, Astrophys. J., 669, L109, 2007.

  19. Influence of ion charge on primary defects creation in crystals irradiated by ions

    CERN Document Server

    Altynov, V A

    2002-01-01

    The model of primary defects formation under ion irradiation of crystals is described. The model is based on suggestion that defects are created as a result of Coulomb repulsion of neighbouring atoms at crystalline lattice ionized by bombarding ions. The changes of average charge of ions and the charge distribution of ions versus the depth of ion penetration to crystal are taken into account. The results of calculations are presented

  20. DETERMINATION OF STRONTIUM IONS IN WATERS WITH A HIGH CONTENT OF SODIUM IONS

    OpenAIRE

    Tatiana Mitina; Nadejda Bondarenco; Diana Grigoras; Elena Botizat; Tudor Lupascu

    2015-01-01

    This paper reports on the influence of sodium ions on experimental determination of strontium ions concentration in waters with a high content of sodium ions by using emission flame photometry and atomic absorption spectroscopy. For the method of emission flame photometry it was shown that at a wavelength of 460.7 nm (spectral emission line of strontium) the emission is linearly dependent on the concentration of sodium ions. The greatest impact of high concentrations of sodium ions on the res...

  1. Experimental Observations of Ion Phase-Space Vortices

    DEFF Research Database (Denmark)

    Pécseli, Hans; Armstrong, R. J.; Trulsen, J.

    1981-01-01

    Experimental observations of ion phase-space vortices are reported. The ion phase-space vortices form in the region of heated ions behind electrostatic ion acoustic shocks. The results are in qualitative agreement with numerical and analytic studies.......Experimental observations of ion phase-space vortices are reported. The ion phase-space vortices form in the region of heated ions behind electrostatic ion acoustic shocks. The results are in qualitative agreement with numerical and analytic studies....

  2. Ion Exchange Formation via Sulfonated Bicomponent Nonwovens

    Science.gov (United States)

    Stoughton, Hannah L.

    For many years ion exchange resins were used to: remove heavy metals from water, recover materials from wastewater, and eliminate harmful gases from the air. While use of these resin beads dominates the ion exchange industry, the beads have limitations that should be considered when decisions are made to employ them. For instance, officials must balance the inherent zero sum surface area and porosity of the materials. This series of studies investigates the use of bicomponent nonwovens as a base substrate for producing high surface area ion exchange materials for the removal of heavy metal ions. Functionalized materials were produced in a two-step process: (1) PET/PE spunbond bicomponent fibers were fractured completely, producing the high surface area nonwoven to be used as the base ion exchange material, and (2) the conditions for functionalizing the PET fibers of the nonwoven webs were investigated where an epoxy containing monomer was grafted to the surface followed by sulfonation of the monomer. The functionalization reactions of the PET fibers were monitored based on: weight gain, FTIR, TOF-SIMS, and SEM. Ion exchange properties were evaluated using titration and copper ion removal capacity from test solutions. The relationship between web structure and removal efficiency of the metal ions was defined through a comparison of the bicomponent and homocomponent nonwovens for copper ion removal efficiency. The investigation revealed that utilizing the high surface area, fractured bicomponent nonwoven ion exchange materials with capacities comparable to commercially available ion exchange resins could be produced.

  3. Laser Ion Acceleration Toward Future Ion Beam Cancer Therapy - Numerical Simulation Sudy-

    CERN Document Server

    Kawata, Shigeo; Nagashima, Toshihiro; Takano, Masahiro; Barada, Daisuke; Kong, Qing; Gu, Yan Jun; Wang, Ping Xiao; Ma, Yan Yun; Wang, Wei Ming

    2013-01-01

    Ion beam has been used in cancer treatment, and has a unique preferable feature to deposit its main energy inside a human body so that cancer cell could be killed by the ion beam. However, conventional ion accelerator tends to be huge in its size and its cost. In this paper a future intense-laser ion accelerator is proposed to make the ion accelerator compact. An intense femtosecond pulsed laser was employed to accelerate ions. The issues in the laser ion accelerator include the energy efficiency from the laser to the ions, the ion beam collimation, the ion energy spectrum control, the ion beam bunching and the ion particle energy control. In the study particle computer simulations were performed to solve the issues, and each component was designed to control the ion beam quality. When an intense laser illuminates a target, electrons in the target are accelerated and leave from the target; temporarily a strong electric field is formed between the high-energy electrons and the target ions, and the target ions ...

  4. Ion Elevators and Escalators in Multilevel Structures for Lossless Ion Manipulations

    Energy Technology Data Exchange (ETDEWEB)

    Ibrahim, Yehia M.; Hamid, Ahmed M.; Cox, Jonathan T.; Garimella, Venkata BS; Smith, Richard D.

    2017-01-19

    We describe two approaches based upon ion ‘elevator’ and ‘escalator’ components that allow moving ions to different levels in structures for lossless ion manipulations (SLIM). Guided by ion motion simulations we designed elevator and escalator components providing essentially lossless transmission in multi-level designs based upon ion current measurements. The ion elevator design allowed ions to efficiently bridge a 4 mm gap between levels. The component was integrated in a SLIM and coupled to a QTOF mass spectrometer using an ion funnel interface to evaluate the m/z range transmitted as compared to transmission within a level (e.g. in a linear section). Mass spectra for singly-charged ions of m/z 600-2700 produced similar mass spectra for both elevator and straight (linear motion) components. In the ion escalator design, traveling waves (TW) were utilized to transport ions efficiently between two SLIM levels. Ion current measurements and ion mobility (IM) spectrometry analysis illustrated that ions can be transported between TW-SLIM levels with no significant loss of either ions or IM resolution. These developments provide a path for the development of multilevel designs providing e.g. much longer IM path lengths, more compact designs, and the implementation of much more complex SLIM devices in which e.g. different levels may operate at different temperatures or with different gases.

  5. Beam losses in heavy ion drivers

    CERN Document Server

    Mustafin, E R; Hofmann, I; Spiller, P J

    2002-01-01

    While beam loss issues have hardly been considered in detail for heavy ion fusion scenarios, recent heavy ion machine developments in different labs (European Organization for Nuclear Research (CERN), Gesellschaft fur Schwerionenforschung (GSI), Institute for Theoretical and Experimental Physics (ITEP), Relativistic Heavy-Ion Collider (RHIC)) have shown the great importance of beam current limitations due to ion losses. Two aspects of beam losses in heavy ion accelerators are theoretically considered: (1) secondary neutron production due to lost ions, and (2) vacuum pressure instability due to charge exchange losses. Calculations are compared and found to be in good agreement with measured data. The application to a Heavy-Ion Driven Inertial Fusion (HIDIF) scenario is discussed. 12 Refs.

  6. Ion trap architectures and new directions

    Science.gov (United States)

    Siverns, James D.; Quraishi, Qudsia

    2017-12-01

    Trapped ion technology has seen advances in performance, robustness and versatility over the last decade. With increasing numbers of trapped ion groups worldwide, a myriad of trap architectures are currently in use. Applications of trapped ions include: quantum simulation, computing and networking, time standards and fundamental studies in quantum dynamics. Design of such traps is driven by these various research aims, but some universally desirable properties have lead to the development of ion trap foundries. Additionally, the excellent control achievable with trapped ions and the ability to do photonic readout has allowed progress on quantum networking using entanglement between remotely situated ion-based nodes. Here, we present a selection of trap architectures currently in use by the community and present their most salient characteristics, identifying features particularly suited for quantum networking. We also discuss our own in-house research efforts aimed at long-distance trapped ion networking.

  7. RF synchronized short pulse laser ion source

    Energy Technology Data Exchange (ETDEWEB)

    Fuwa, Yasuhiro, E-mail: fuwa@kyticr.kuicr.kyoto-u.ac.jp; Iwashita, Yoshihisa; Tongu, Hiromu; Inoue, Shunsuke; Hashida, Masaki; Sakabe, Shuji [Institute for Chemical Research, Kyoto University, Uji, Kyoto 611-0011 (Japan); Okamura, Masahiro [Collider-Accelerator Department, Brookhaven National Laboratory, Upton, New York 11973 (United States); Yamazaki, Atsushi [Graduate School of Engineering, Nagoya University, Nagoya, Aichi 464-8603 (Japan)

    2016-02-15

    A laser ion source that produces shortly bunched ion beam is proposed. In this ion source, ions are extracted immediately after the generation of laser plasma by an ultra-short pulse laser before its diffusion. The ions can be injected into radio frequency (RF) accelerating bucket of a subsequent accelerator. As a proof-of-principle experiment of the ion source, a RF resonator is prepared and H{sub 2} gas was ionized by a short pulse laser in the RF electric field in the resonator. As a result, bunched ions with 1.2 mA peak current and 5 ns pulse length were observed at the exit of RF resonator by a probe.

  8. Microvillar ion channels: cytoskeletal modulation of ion fluxes.

    Science.gov (United States)

    Lange, K

    2000-10-21

    The recently presented theory of microvillar Ca(2+)signaling [Lange, K. (1999) J. Cell. Physiol.180, 19-35], combined with Manning's theory of "condensed counterions" in linear polyelectrolytes [Manning, G. S. (1969). J. Chem. Phys.51, 924-931] and the finding of cable-like ion conductance in actin filaments [Lin, E. C. & Cantiello, H. F. (1993). Biophys. J.65, 1371-1378], allows a systematic interpretation of the role of the actin cytoskeleton in ion channel regulation. Ion conduction through actin filament bundles of microvilli exhibits unique nonlinear transmission properties some of which closely resemble that of electronic semiconductors: (1) bundles of microfilaments display significant resistance to cation conduction and (2) this resistance is decreased by supply of additional energy either as thermal, mechanical or electromagnetic field energy. Other transmission properties, however, are unique for ionic conduction in polyelectrolytes. (1) Current pulses injected into the filaments were transformed into oscillating currents or even into several discrete charge pulses closely resembling that of single-channel recordings. Discontinuous transmission is due to the existence of counterion clouds along the fixed anionic charge centers of the polymer, each acting as an "ionic capacitor". (2) The conductivity of linear polyelectrolytes strongly decreases with the charge number of the counterions; thus, Ca(2+)and Mg(2+)are effective modulator of charge transfer through linear polyelectrolytes. Field-dependent formation of divalent cation plugs on either side of the microvillar conduction line may generate the characteristic gating behavior of cation channels. (3) Mechanical movement of actin filament bundles, e.g. bending of hair cell microvilli, generates charge translocations along the filament structure (mechano-electrical coupling). (4) Energy of external fields, by inducing molecular dipoles within the polyelectrolyte matrix, can be transformed into mechanical

  9. Dual-Polarity Ion Trap Mass Spectrometry: Dynamic Monitoring and Controlling Gas-phase Ion-Ion Reactions

    Science.gov (United States)

    He, Muyi; Jiang, You; Guo, Dan; Xiong, Xingchuang; Fang, Xiang; Xu, Wei

    2017-07-01

    A dual-polarity linear ion trap (LIT) mass spectrometer was developed in this study, and the method for simultaneously controlling and detecting cations and anions was proposed and realized in the LIT. With the application of an additional dipolar DC field on the ejection electrodes of an LIT, dual-polarity mass spectra could be obtained, which include both the mass-to-charge ( m/z) ratio and charge polarity information of an ion. Compared with conventional method, the ion ejection and detection efficiency could also be improved by about one-fold. Furthermore, ion-ion reactions within the LIT could be dynamically controlled and monitored by manipulating the distributions of ions with opposite charge polarities. This method was then used to control and study the reaction kinetics of ion-ion reactions, including electron transfer dissociation (ETD) and charge inversion reactions. A dual-polarity collision-induced dissociation (CID) experiment was proposed and performed to enhance the sequence coverage of a peptide ion. Ion trajectory simulations were also carried out for concept validation and system optimization.

  10. Status report on electron cyclotron resonance ion sources at the Heavy Ion Medical Accelerator in Chiba

    CERN Document Server

    Kitagawa, A; Sekiguchi, M; Yamada, S; Jincho, K; Okada, T; Yamamoto, M; Hattori, T G; Biri, S; Baskaran, R; Sakata, T; Sawada, K; Uno, K

    2000-01-01

    The Heavy Ion Medical Accelerator in Chiba at the National Institute of Radiological Sciences (NIRS) is not only dedicated to cancer therapy, it is also utilized with various ion species for basic experiments of biomedical science, physics, chemistry, etc. Two electron cyclotron resonance (ECR) ion sources are installed for production of gaseous ions. One of them, the NIRS-ECR, is a 10 GHz ECR ion source, and is mainly operated to produce C/sup 4+/ ions for daily clinical treatment. This source realizes good reproducibility and reliability and it is easily operated. The other source, the NIRS-HEC, is an 18 GHz ECR ion source that is expected to produce heavier ion species. The output ion currents of the NIRS-ECR and the NIRS-HEC are 430e mu A for C/sup 4+/ and 1.1e mA for Ar/sup 8+/, respectively. (14 refs).

  11. Effect of ion clouds micromotion on measured signal in Fourier transform ion cyclotron resonance: Computer simulation.

    Science.gov (United States)

    Vladimirov, Gleb; Kostyukevich, Yury; Kharybin, Oleg; Nikolaev, Eugene

    2017-08-01

    Particle-in-cell-based realistic simulation of Fourier transform ion cyclotron resonance experiments could be used to generate ion trajectories and a signal induced on the detection electrodes. It has been shown recently that there is a modulation of "reduced" cyclotron frequencies in ion cyclotron resonance signal caused by Coulomb interaction of ion clouds. In this work it was proposed to use this modulation in order to determine frequency difference between an ion of known m/z and all other ions generating signal in ion cyclotron resonance cell. It is shown that with an increase of number of ions in ion cyclotron resonance trap, the modulation index increases, which lead to a decrease in the accuracy of determination of peak intensities by super Fourier transform resolution methods such as filter diagonalization method.

  12. Ion beam modification of solids ion-solid interaction and radiation damage

    CERN Document Server

    Wesch, Werner

    2016-01-01

    This book presents the method of ion beam modification of solids in realization, theory and applications in a comprehensive way. It provides a review of the physical basics of ion-solid interaction and on ion-beam induced structural modifications of solids. Ion beams are widely used to modify the physical properties of materials. A complete theory of ion stopping in matter and the calculation of the energy loss due to nuclear and electronic interactions are presented including the effect of ion channeling. To explain structural modifications due to high electronic excitations, different concepts are presented with special emphasis on the thermal spike model. Furthermore, general concepts of damage evolution as a function of ion mass, ion fluence, ion flux and temperature are described in detail and their limits and applicability are discussed. The effect of nuclear and electronic energy loss on structural modifications of solids such as damage formation, phase transitions and amorphization is reviewed for ins...

  13. Anthropogenic perturbations of tropospheric ion composition

    Science.gov (United States)

    Beig, G.; Brasseur, G.

    This paper presents a simple model of the vertical distribution of the most abundant positive ions in the troposphere. The model is based on a simple ion chemical scheme, measured rate constants, and observed or calculated atmospheric densities of parent neutral compounds. It suggests that in many cases the most abundant gaseous ions are heavy protonated water cluster ions of pyridine, picoline and lutidine with ammonia molecules attached (pyridinated cluster ions) in the lower troposphere (below 7 km altitude), acetone cluster ions in the upper troposphere (between 7 and 15 km) and methyl cyanide cluster ions above 15 km. The relative abundance of heavy clustered aerosol ions is predicted to be highest near the surface. The model suggests that ion composition could be perturbed as a result of human activities (i.e., increasing emissions of parent neutral species including alkaline compounds), and that in particular, the relative atmospheric abundance of pyridinated water cluster ions is increasing dramatically and should further increase in the future.

  14. Computational modeling of ion transport through nanopores

    Science.gov (United States)

    Modi, Niraj; Winterhalter, Mathias; Kleinekathöfer, Ulrich

    2012-09-01

    Nanoscale pores are ubiquitous in biological systems while artificial nanopores are being fabricated for an increasing number of applications. Biological pores are responsible for the transport of various ions and substrates between the different compartments of biological systems separated by membranes while artificial pores are aimed at emulating such transport properties. As an experimental method, electrophysiology has proven to be an important nano-analytical tool for the study of substrate transport through nanopores utilizing ion current measurements as a probe for the detection. Independent of the pore type, i.e., biological or synthetic, and objective of the study, i.e., to model cellular processes of ion transport or electrophysiological experiments, it has become increasingly important to understand the dynamics of ions in nanoscale confinements. To this end, numerical simulations have established themselves as an indispensable tool to decipher ion transport processes through biological as well as artificial nanopores. This article provides an overview of different theoretical and computational methods to study ion transport in general and to calculate ion conductance in particular. Potential new improvements in the existing methods and their applications are highlighted wherever applicable. Moreover, representative examples are given describing the ion transport through biological and synthetic nanopores as well as the high selectivity of ion channels. Special emphasis is placed on the usage of molecular dynamics simulations which already have demonstrated their potential to unravel ion transport properties at an atomic level.

  15. Spectroscopy with trapped highly charged ions

    Energy Technology Data Exchange (ETDEWEB)

    Beiersdorfer, P

    2008-01-23

    We give an overview of atomic spectroscopy performed on electron beam ion traps at various locations throughout the world. Spectroscopy at these facilities contributes to various areas of science and engineering, including but not limited to basic atomic physics, astrophysics, extreme ultraviolet lithography, and the development of density and temperature diagnostics of fusion plasmas. These contributions are accomplished by generating, for example, spectral surveys, making precise radiative lifetime measurements, accounting for radiative power emitted in a given wavelength band, illucidating isotopic effects, and testing collisional-radiative models. While spectroscopy with electron beam ion traps had originally focused on the x-ray emission from highly charged ions interacting with the electron beam, the operating modes of such devices have expanded to study radiation in almost all wavelength bands from the visible to the hard x-ray region; and at several facilities the ions can be studied even in the absence of an electron beam. Photon emission after charge exchange or laser excitation has been observed, and the work is no longer restricted to highly charged ions. Much of the experimental capabilities are unique to electron beam ion traps, and the work performed with these devices cannot be undertaken elsewhere. However, in other areas the work on electron beam ion traps rivals the spectroscopy performed with conventional ion traps or heavy-ion storage rings. The examples we present highlight many of the capabilities of the existing electron beam ion traps and their contributions to physics.

  16. Exploring Quantum Physics with Trapped Ions

    Science.gov (United States)

    Leibfried, Dietrich

    2017-04-01

    Trapped ions were among the first systems, where a single quantum particle can be confined and manipulated in almost perfect isolation from its environment. This makes ions prime candidates for high precision experiments and for demonstrating textbook quantum mechanical principles. Several ions in the same trap can couple strongly to each other through their Coulomb interaction. This enables entangling quantum logic gates and as a consequence, many experiments with trapped ions have concentrated on advancing quantum information processing in the last 20 years. While much work still needs to be done before a scalable, fault tolerant universal quantum processor can be realized in any system, the advances with ions have enabled exploration of new avenues, such as quantum simulation, quantum logic spectroscopy for ion clocks, and for molecular ion and highly charged ion spectroscopy. Lately, ion-based sensors and ideas for hybrid quantum systems that aim to couple trapped ions to photons, neutral atoms, superconducting circuits, micro-mechanical oscillators or other quantum coherent entities are gaining momentum.

  17. Novel electrostatic column for ion projection lithography

    Energy Technology Data Exchange (ETDEWEB)

    Chalupka, A.; Stengl, G.; Buschbeck, H.; Lammer, G.; Vonach, H.; Fischer, R.; Hammel, E.; Loeschner, H.; Nowak, R.; Wolf, P. (IMS - Ion Microfabrication Systems GmbH, A-1020 Vienna (Austria)); Finkelstein, W.; Hill, R.W. (Advanced Lithography Group, Columbia, Maryland 21045 (United States)); Berry, I.L. (Department of Defense, Microelectronics Research Laboratory, Columbia, Maryland 21045 (United States)); Harriott, L.R. (AT T Bell Laboratories, Murray Hill, New Jersey 07974 (United States)); Melngailis, J. (University of Maryland, College Park, Maryland 20742 (United States)); Randall, J.N. (Texas Instruments, Dallas, Texas 75243 (United States)); Wolfe, J.C. (University of Houston, Houston, Texas 77204 (United States)); Stroh, H.; Wollnik, H. (University of Giessen, D-35392 Giessen (Germany)); Mondelli, A.A.; Petillo, J.J. (Science Applications International Corporation, McLean, Virginia 22102 (United States)); Leung, K. (Lawrence Berkeley Laboratory, University of Californi

    1994-11-01

    Ion projection lithography (IPL) is being considered for high volume sub-0.25-[mu]m lithography. A novel ion-optical column has been designed for exposing 20[times]20 mm[sup 2] fields at 3[times] reduction from stencil mask to wafer substrates. A diverging lens is realized by using the stencil mask as the first electrode of the ion-optical column. The second and third electrode form an accelerating field lens. The aberrations of the first two lenses (diverging lens and field lens) are compensated by an asymmetric Einzel lens projecting an ion image of the stencil mask openings onto the wafer substrate with better than 2 mrad telecentricity. Less than 30 nm intrafield distortion was calculated within 20[times]20 mm[sup 2] exposure fields. The calculation uncertainty is estimated to be about 10 nm. The calculation holds for helium ions with [approx]10 keV ion energy at the stencil mask and 150 keV ion energy at the wafer plane. A virtual ion source size of 10 [mu]m has been assumed. The calculated chromatic aberrations are less than 60 nm, assuming 6 eV energy spread of the ions extracted from a duoplasmatron source. Recently a multicusp ion source has been developed for which preliminary results indicate an energy spread of less than 2 eV. Thus, with a multicusp source chromatic aberrations of less than 20 nm are to be expected. The ion energy at the crossover between the field lens and the asymmetric Einzel lens is 200 keV. Therefore, stochastic space charge induced degradations in resolution can be kept sufficiently low. The divergence of the ion image projected to the wafer plane is less than 2 mrad. Thus, the usable'' depth of focus for the novel ion optics is in the order of 10 [mu]m.

  18. IOOC Organizational Network (ION) Project

    Science.gov (United States)

    Dean, H.

    2013-12-01

    In order to meet the growing need for ocean information, research communities at the national and international levels have responded most recently by developing organizational frameworks that can help to integrate information across systems of existing networks and standardize methods of data gathering, management, and processing that facilitate integration. To address recommendations and identified challenges related to the need for a better understanding of ocean observing networks, members of the U.S. Interagency Ocean Observation Committee (IOOC) supported pursuing a project that came to be titled the IOOC Organizational Network (ION). The ION tool employs network mapping approaches which mirror approaches developed in academic literature aimed at understanding political networks. Researchers gathered data on the list of global ocean observing organizations included in the Framework for Ocean Observing (FOO), developed in 2012 by the international Task Team for an Integrated Framework for Sustained Ocean Observing. At the international scale, researchers reviewed organizational research plans and documents, websites, and formal international agreement documents. At the U.S. national scale, researchers analyzed legislation, formal inter-agency agreements, work plans, charters, and policy documents. Researchers based analysis of relationships among global organizations and national federal organizations on four broad relationship categories: Communications, Data, Infrastructure, and Human Resources. In addition to the four broad relationship categories, researchers also gathered data on relationship instrument types, strength of relationships, and (at the global level) ocean observing variables. Using network visualization software, researchers then developed a series of dynamic webpages. Researchers used the tool to address questions identified by the ocean observing community, including identifying gaps in global relationships and the types of tools used to

  19. Ion Mobility Spectrometer Field Test

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Nicholas [Argonne National Lab. (ANL), Argonne, IL (United States). Nuclear Engineering Division; McLain, Derek [Argonne National Lab. (ANL), Argonne, IL (United States). Nuclear Engineering Division; Steeb, Jennifer [Argonne National Lab. (ANL), Argonne, IL (United States). Nuclear Engineering Division

    2017-12-20

    The Morpho Saffran Itemizer 4DX Ion Mobility Spectrometer previously used to detect uranium signatures in FY16 was used at the former New Brunswick Facility, a past uranium facility located on site at Argonne National Laboratory. This facility was chosen in an attempt to detect safeguards relevant signatures and has a history of processing uranium at various enrichments, chemical forms, and purities; various chemicals such as nitric acid, uranium fluorides, phosphates and metals are present at various levels. Several laboratories were sampled for signatures of nuclear activities around the laboratory. All of the surfaces that were surveyed were below background levels of the radioanalytical instrumentation and determined to be radiologically clean.

  20. Mutation induction by ion beams in plants

    Energy Technology Data Exchange (ETDEWEB)

    Tanaka, Atsushi [Japan Atomic Energy Research Inst., Takasaki, Gunma (Japan). Takasaki Radiation Chemistry Research Establishment

    2001-03-01

    The effect of ion beams such as C, He, and Ne ions was investigated on the mutation induction in plants with the expectation that ion beams of high linear energy transfer (LET) can frequently produce large DNA alternation such as inversion, translocation and large deletion rather than point mutation. Mutation frequency was investigated using Arabidopsis visible phenotype loci and was 8 to 33 fold higher for 220 MeV carbon ions than for electrons. Mutation spectrum was investigated on the flower color of chrysanthemum cv to find that flower mutants induced by ion beams show complex and stripe types rather than single color. Polymerase chain reaction analysis was performed to investigate DNA alteration of mutations. In conclusion, the characteristics of ion beams for the mutation induction are 1) high frequency, 2) broad mutation spectrum, and 3) novel mutants. (S. Ohno)

  1. High-Resolution Ion Cyclotron Mobility Spectrometry

    Science.gov (United States)

    Merenbloom, Samuel I.; Glaskin, Rebecca S.; Henson, Zachary B.; Clemmer, David E.

    2009-01-01

    A novel ion mobility spectrometry instrument incorporating a cyclotron geometry drift tube is presented. The drift tube consists of eight regions, four curved drift tubes and four ion funnels. Packets of ions are propagated around the drift tube by changing the drift field at a frequency that is resonant with the ion’s drift time through each region. The approach trims each packet of ions as it leaves and enters each new region. An electrostatic gate allows ions to be kept in the drift tube for numerous cycles, increasing the ability to resolve specified ions. We demonstrate the approach by isolating the [M+2H]2+ or [M+3H]3+ charge state of substance P as well as individual trisaccharide isomers from a mixture of melezitose and raffinose. Resolving powers in excess of 300 are obtainable with this approach. PMID:19143495

  2. A Plasma Ion Source for ISOLTRAP

    CERN Document Server

    Skov, Thomas Guldager

    2016-01-01

    In this report, my work testing the new Penning ion source as a summer student at ISOLTRAP is described. The project was composed of three stages: (1) Setting up a test laboratory in building 275, (2) characterizing the ion source, and (3) implementing and testing the source in the ISOLTRAP setup. After setting up the test laboratory, the ion source was tested in a constant pressure environment with produced ion currents in the range of nA . An extensive scan of the source ion current versus operating parameters (pressure, voltage) was performed. A setup with pulsed gas flow was also tested, allowing a reduction of the gas load on the vacuum system. The behavior of the ion source together with the ISOLTRAP setup was also investigated, allowing to understand current limitations and future directions of improvement.

  3. Binding of Ca Ions by Paramecium caudatum

    Science.gov (United States)

    Naitoh, Yutaka; Yasumasu, Ikuo

    1967-01-01

    Binding of 45Ca by live Paramecium caudatum was determined under various external ionic conditions. It was found that calcium uptake was separable into at least two components, a rapid and a slow one. The rapid component was influenced by the presence of certain other ions in a manner which agrees with the law of mass action. It appears that an ion exchange system may be involved in a binding equilibrium established between Paramecium, Ca++, and certain other ions. K+, Rb+, and Ba++ in the equilibrium medium are among those ions which inhibit calcium uptake. It is proposed that liberation of Ca++ from binding sites on Paramecium by an exchange reaction with competing ions is the first step in the mechanism of ciliary reversal in the response to external application of these ions. PMID:6033587

  4. Microsecond pulsed hydrogen/deuterium exchange of electrosprayed ubiquitin ions stored in a linear ion trap.

    Science.gov (United States)

    Rajabi, Khadijeh

    2015-02-07

    A pulse of D2O vapour on the order of microseconds is allowed to react with the +6 to +9 charge states of ubiquitin confined in a linear ion trap (LIT). Two envelopes of peaks are detected for the ions of ubiquitin, corresponding to the ions that exchange more quickly and more slowly. The deuterium uptake of the protonated sites on ubiquitin ions accounts for the ion population with the fast exchange. The hydrogen/deuterium exchange (HDX) kinetics of ubiquitin ions trapped in the LIT for 200 ms showed comparable structural transitions to those trapped for 300 ms. When ions are trapped for longer, i.e. up to 2000 ms, mainly the slow exchanging ion population is detected. In all experiments the +7 ions exchange the most, suggesting a short distance between the surface protonated sites and nearby charged sites, and concomitantly high accessibility of surface protonated sites towards D2O. The +6 ions are more compact than the +7 ions but have one fewer protonated site, therefore fewer surface availabilities for D2O attack. The data suggest that the +6 ions keep most of their solution-phase contacts intact while the hydrophobic core is slightly interrupted in the +7 ions, possibly due to the exposure of charged His68 that is normally buried in the hydrophobic pocket. The +8 and +9 ions have more protonated sites but are less compact than the +7 ions because of Coulombic repulsion, resulting in a larger distance between the protonated sites and the basic sites. The data indicate that the HDX mechanism of ions with the slower exchange corresponding to the second envelope of peaks is primarily governed via a relay mechanism. The results suggest that the pulsed HDX MS method is sampling a population of ubiquitin ions with a similar backbone fold to the solution.

  5. LHC Report: Positive ion run!

    CERN Multimedia

    Mike Lamont for the LHC Team

    2011-01-01

    The current LHC ion run has been progressing very well. The first fill with 358 bunches per beam - the maximum number for the year - was on Tuesday, 15 November and was followed by an extended period of steady running. The quality of the beam delivered by the heavy-ion injector chain has been excellent, and this is reflected in both the peak and the integrated luminosity.   The peak luminosity in ATLAS reached 5x1026 cm-2s-1, which is a factor of ~16 more than last year's peak of 3x1025 cm-2s-1. The integrated luminosity in each of ALICE, ATLAS and CMS is now around 100 inverse microbarn, already comfortably over the nominal target for the run. The polarity of the ALICE spectrometer and solenoid magnets was reversed on Monday, 28 November with the aim of delivering another sizeable amount of luminosity in this configuration. On the whole, the LHC has been behaving very well recently, ensuring good machine availability. On Monday evening, however, a faulty level sensor in the cooling towe...

  6. LHC Report: Ions cross protons

    CERN Multimedia

    Reyes Alemany Fernandez for the LHC team

    2013-01-01

    The LHC starts the New Year facing a new challenge: proton-lead collisions in the last month before the shutdown in mid-February.    The first stable beams were achieved on 20 January with 13 individual bunches per beam. In the next fill, the first bunch-trains were injected and stable beams were achieved with 96 proton on 120 ion bunches.  This fill was very important because we were able to study the so-called moving long-range beam-beam encounters. Long-range encounters, which are also seen in proton-proton runs, occur when the bunches in the two beams “see” each other as they travel in the same vacuum chamber at either side of the experiments.  The situation becomes more complicated with proton-lead ions because the two species have different revolution times (until the frequencies are locked at top energy- see “Cogging exercises”) and thus these encounters move. We found that this effect does not cause significant beam losses...

  7. Heavy Ion Physics at CMS

    CERN Document Server

    Veres, Gabor

    2017-01-01

    In the present proceedings recent heavy ion results from the Compact Muon Solenoid collaboration at the LHC are presented. These contain comparisons between small and large collision systems, as well as studies of energy evolution, thus include data collected in proton-proton collisions at 13 TeV (2015 and 2016), proton-proton and lead-lead collisions at 5 TeV (2015), and proton-lead collisions at 5 TeV and 8 TeV (2016) center-of-mass energy per nucleon pair. They provide new insights into the properties of the extremely high density and high temperature matter created in heavy ion collisions, while pointing out similarities and differences in comparison to smaller collision systems. These include gluon distribution functions in the lead nucleus; the azimuthal anisotropy of final state particle distributions in all the three different collision systems; charge separation signals from proton-lead collisions and consequences for the Chiral Magnetic Effect; new studies of parton energy loss and its dependence on...

  8. Multifunctional scanning ion conductance microscopy.

    Science.gov (United States)

    Page, Ashley; Perry, David; Unwin, Patrick R

    2017-04-01

    Scanning ion conductance microscopy (SICM) is a nanopipette-based technique that has traditionally been used to image topography or to deliver species to an interface, particularly in a biological setting. This article highlights the recent blossoming of SICM into a technique with a much greater diversity of applications and capability that can be used either standalone, with advanced control (potential-time) functions, or in tandem with other methods. SICM can be used to elucidate functional information about interfaces, such as surface charge density or electrochemical activity (ion fluxes). Using a multi-barrel probe format, SICM-related techniques can be employed to deposit nanoscale three-dimensional structures and further functionality is realized when SICM is combined with scanning electrochemical microscopy (SECM), with simultaneous measurements from a single probe opening up considerable prospects for multifunctional imaging. SICM studies are greatly enhanced by finite-element method modelling for quantitative treatment of issues such as resolution, surface charge and (tip) geometry effects. SICM is particularly applicable to the study of living systems, notably single cells, although applications extend to materials characterization and to new methods of printing and nanofabrication. A more thorough understanding of the electrochemical principles and properties of SICM provides a foundation for significant applications of SICM in electrochemistry and interfacial science.

  9. Measurement of ultra-low ion energy of decelerated ion beam using a deflecting electric field

    Energy Technology Data Exchange (ETDEWEB)

    Thopan, P.; Suwannakachorn, D.; Tippawan, U. [Plasma and Beam Physics Research Facility, Department of Physics and Materials Science, Faculty of Science, Chiang Mai University, Chiang Mai 50200 (Thailand); Yu, L.D., E-mail: yuld@thep-center.org [Plasma and Beam Physics Research Facility, Department of Physics and Materials Science, Faculty of Science, Chiang Mai University, Chiang Mai 50200 (Thailand); Thailand Center of Excellence in Physics, Commission on Higher Education, 328 Si Ayutthaya Road, Bangkok 10400 (Thailand)

    2015-12-15

    In investigation on ultra-low-energy ion bombardment effect on DNA, an ion beam deceleration lens was developed for high-quality ultra-low-energy ion beam. Measurement of the ion energy after deceleration was necessary to confirm the ion beam really decelerated as theoretically predicted. In contrast to conventional methods, this work used a simple deflecting electrostatic field after the deceleration lens to bend the ion beam. The beam bending distance depended on the ion energy and was described and simulated. A system for the measurement of the ion beam energy was constructed. It consisted of a pair of parallel electrode plates to generate the deflecting electrical field, a copper rod measurement piece to detect ion beam current, a vernier caliper to mark the beam position, a stepping motor to translate the measurement rod, and a webcam-camera to read the beam bending distance. The entire system was installed after the ion-beam deceleration lens inside the large chamber of the bioengineering vertical ion beam line. Moving the measurement rod across the decelerated ion beam enabled to obtain beam profiles, from which the beam bending distance could be known and the ion beam energy could be calculated. The measurement results were in good agreement with theoretical and simulated results.

  10. Electrochemical ion separation in molten salts

    Energy Technology Data Exchange (ETDEWEB)

    Spoerke, Erik David; Ihlefeld, Jon; Waldrip, Karen; Wheeler, Jill S.; Brown-Shaklee, Harlan James; Small, Leo J.; Wheeler, David R.

    2017-12-19

    A purification method that uses ion-selective ceramics to electrochemically filter waste products from a molten salt. The electrochemical method uses ion-conducting ceramics that are selective for the molten salt cations desired in the final purified melt, and selective against any contaminant ions. The method can be integrated into a slightly modified version of the electrochemical framework currently used in pyroprocessing of nuclear wastes.

  11. The Aarhus Ion Micro-Trap Project

    DEFF Research Database (Denmark)

    Miroshnychenko, Yevhen; Nielsen, Otto; Poulsen, Gregers

    and installed in an ultra high vacuum chamber, which includes an ablation oven for all-optical loading of the trap [2]. The next steps on the project are to demonstrate the operation of the micro-trap and the cooling of ions using fiber delivered light. [1] D. Grant, Development of Micro-Scale Ion traps, Master......As part of our involvement in the EU MICROTRAP project, we have designed, manufactured and assembled a micro-scale ion trap with integrated optical fibers. These prealigned fibers will allow delivering cooling laser light to single ions. Therefore, such a trap will not require any direct optical...

  12. Neutral beamline with improved ion energy recovery

    Science.gov (United States)

    Kim, Jinchoon

    1984-01-01

    A neutral beamline employing direct energy recovery of unneutralized residual ions is provided which enhances the energy recovery of the full energy ion component of the beam exiting the neutralizer cell, and thus improves the overall neutral beamline efficiency. The unneutralized full energy ions exiting the neutralizer are deflected from the beam path and the electrons in the cell are blocked by a magnetic field applied transverse to the beam direction in the neutral izer exit region. The ions which are generated at essentially ground potential and accelerated through the neutralizer cell by a negative acceleration voltage are collected at ground potential. A neutralizer cell exit end region is provided which allows the magnetic and electric fields acting on the exiting ions to be loosely coupled. As a result, the fractional energy ions exiting the cell are reflected onto and collected at an interior wall of the neutralizer formed by the modified end geometry, and thus do not detract from the energy recovery efficiency of full energy ions exiting the cell. Electrons within the neutralizer are prevented from exiting the neutralizer end opening by the action of crossed fields drift (ExB) and are terminated to a collector collar around the downstream opening of the neutralizer. The correct combination of the extended neutralizer end structure and the magnet region is designed so as to maximize the exit of full energy ions and to contain the fractional energy ions.

  13. Oxygen ions observed near Saturn's A ring.

    Science.gov (United States)

    Waite, J H; Cravens, T E; Ip, W-H; Kasprzak, W T; Luhmann, J G; McNutt, R L; Niemann, H B; Yelle, R V; Mueller-Wodarg, I; Ledvina, S A; Scherer, S

    2005-02-25

    Ions were detected in the vicinity of Saturn's A ring by the Ion and Neutral Mass Spectrometer (INMS) instrument onboard the Cassini Orbiter during the spacecraft's passage over the rings. The INMS saw signatures of molecular and atomic oxygen ions and of protons, thus demonstrating the existence of an ionosphere associated with the A ring. A likely explanation for these ions is photoionization by solar ultraviolet radiation of neutral O2 molecules associated with a tenuous ring atmosphere. INMS neutral measurements made during the ring encounter are dominated by a background signal.

  14. Heavy Ion Fusion Accelerator Research (HIFAR)

    Energy Technology Data Exchange (ETDEWEB)

    1991-04-01

    This report discusses the following topics: emittance variations in current-amplifying ion induction lina; transverse emittance studies of an induction accelerator of heavy ions; drift compression experiments on MBE-4 and related emittance; low emittance uniform- density C{sub s}+ sources for heavy ion fusion accelerator studies; survey of alignment of MBE-4; time-of-flight dependence on the MBE-4 quadrupole voltage; high order calculation of the multiple content of three dimensional electrostatic geometries; an induction linac injector for scaled experiments; induction accelerator test module for HIF; longitudinal instability in HIF beams; and analysis of resonant longitudinal instability in a heavy ion induction linac.

  15. 11. international conference on ion sources

    Energy Technology Data Exchange (ETDEWEB)

    Leitner, D.; Lyneis, C.; Cheng, D.; Galloway, M.L.; Leitner, M.; Todd, D.S.; Ciavola, G.; Gammino, S.; Celona, L.; Ando, L.; Torrisi, L.; Cavenago, M.; Galata, A.; Spaedtke, P.; Tinschert, K.; Lang, R.; Iannucci, R.; Leroy, R.; Barue, C.; Hitz, D.; Koivisto, H.; Suominen, P.; Tarvainen, O.; Beijers, H.; Brandenburg, S.; Vanrooyen, D.; Hillo, C.; Kuchler, D.; Homeyer, H.; Rohrich, J.; Schachter, L.; Dobrescu, S.; Nakagawa, T.; Higurashi, Y.; Kidera, M.; Aihara, T.; Kase, M.; Goto, A.; Yang, Y.; Zhao, H.W.; Zhang, Z.M.; Zhang, X.Z.; Guo, X.H.; He, W.E.; Sun, L.T.; Yuan, P.; Song, M.T.; Xie, Z.Q.; Cao, Y.; Zhan, W.L.; Wei, B.W.; Bricault, P.; Lau, C.; Essabaa, S.; Cheikh Mhamed, M.; Bajeat, O.; Ducourtieux, M.; Lefort, H.; Panteleev, V.N.; Barzakh, A.E.; Fedorov, D.V.; Ionan, A.M.; Mezilev, K.A.; Moroz, F.V.; Orlov, S.Y.; Volkov, Y.M.; Andrighetto, A.; Lhersonneau, G.; Rizzi, V.; Tecchio, L.B.; Dubois, M.; Gaubert, G.; Jardins, P.; Lecesne, N.; Leroy, R.; Pacquet, J.Y.; Saint Laurent, M.G.; Villari, A.C.O.; Bajeat, O.; Essabaa, S.; Lau, C.; Menna, M.; Franberg, H.; Ammann, M.; Gdggeler, H.W.; Koster, U.; Allen, F.; Biedermann, C.; Radtke, R.; Ames, F.; Baartman, R.; Bricault, P.; Jayamanna, K.; Lamy, T.; McDonald, M.; Olivo, M.; Schmorl, P.; Yuan, D.H.L.; Asaji, T.; Sasaki, H.; Kato, Y.; Atabaev, B.; Radjabov, S.S.; Akhmadjanova, M.K.; Yuzikaeva, F.R.; Baoqun, Cui; Liqiang, Li; Yingjun, Ma; Shengyun, Zhu; Cong, Jiang

    2005-07-01

    This document gathers the summaries of the presentations made at ICIS05 (international conference on ion sources). It can be organized into 3 main topics: 1) 'fundamentals and theory' that deals with plasma, beam extraction, transport and emittance, diagnostics and simulation; 2) 'various types of ion sources' that include ECRIS, EBIS, microwave, negative, radioactive, polarized and laser ion sources, and charge breeders; and 3) 'ion sources and applications' in fields like accelerator injection, fusion energy, space propulsion, mass spectrometry, and neutron and cluster and rare nuclide production.

  16. Potential biomedical applications of ion beam technology

    Science.gov (United States)

    Banks, B. A.; Weigand, A. J.; Van Kampen, C. L.; Babbush, C. A.

    1976-01-01

    Electron bombardment ion thrusters used as ion sources have demonstrated a unique capability to vary the surface morphology of surgical implant materials. The microscopically rough surface texture produced by ion beam sputtering of these materials may result in improvements in the biological response and/or performance of implanted devices. Control of surface roughness may result in improved attachment of the implant to soft tissue, hard tissue, bone cement, or components deposited from blood. Potential biomedical applications of ion beam texturing discussed include: vascular prostheses, artificial heart pump diaphragms, pacemaker fixation, percutaneous connectors, orthopedic prosthesis fixation, and dental implants.

  17. Paper-based potentiometric ion sensing.

    Science.gov (United States)

    Lan, Wen-Jie; Zou, Xu U; Hamedi, Mahiar M; Hu, Jinbo; Parolo, Claudio; Maxwell, E Jane; Bühlmann, Philippe; Whitesides, George M

    2014-10-07

    This paper describes the design and fabrication of ion-sensing electrochemical paper-based analytical devices (EPADs) in which a miniaturized paper reference electrode is integrated with a small ion-selective paper electrode (ISPE) for potentiometric measurements. Ion-sensing EPADs use printed wax barriers to define electrochemical sample and reference zones. Single-layer EPADs for sensing of chloride ions include wax-defined sample and reference zones that each incorporate a Ag/AgCl electrode. In EPADs developed for other electrolytes (potassium, sodium, and calcium ions), a PVC-based ion-selective membrane is added to separate the sample zone from a paper indicator electrode. After the addition of a small volume (less than 10 μL) of sample and reference solutions to different zones, ion-sensing EPADs exhibit a linear response, over 3 orders of magnitude, in ranges of electrolyte concentrations that are relevant to a variety of applications, with a slope close to the theoretical value (59.2/z mV). Ion-selective EPADs provide a portable, inexpensive, and disposable way of measuring concentrations of electrolyte ions in aqueous solutions.

  18. Spectroscopy of mobility-selected biomolecular ions.

    Science.gov (United States)

    Papadopoulos, Georgios; Svendsen, Annette; Boyarkin, Oleg V; Rizzo, Thomas R

    2011-01-01

    We describe here experiments that combine differential ion mobility, which separates conformational isomers of biomolecular ions, with electronic spectroscopy in a cold, radio-frequency ion trap. Although the low temperature attainable in a cold ion trap greatly simplifies the electronic spectra of large molecules, conformational heterogeneity can still be a significant source of congestion, complicating spectroscopic analysis. We demonstrate here that using differential ion mobility to separate gas-phase peptide conformers before injecting them into a cold ion trap allows one to decompose a dense spectrum into contributions from different conformational families. In the inverse sense, cold ion spectroscopy can be used as a conformation-specific detector for ion mobility, allowing one to separate an unresolved peak into contributions from different conformational families. The doubly protonated peptide bradykinin serves as a good test case for the marriage of these two techniques as it exhibits a considerable degree of conformational heterogeneity that results in a highly congested electronic spectrum. Our results demonstrate the feasibility and advantages of directly coupling ion mobility with spectroscopy and provide a diagnostic of conformational isomerization of this peptide after being produced in the gas phase by electrospray.

  19. Neutral beamline with improved ion energy recovery

    Science.gov (United States)

    Dagenhart, William K.; Haselton, Halsey H.; Stirling, William L.; Whealton, John H.

    1984-01-01

    A neutral beamline generator with unneutralized ion energy recovery is provided which enhances the energy recovery of the full energy ion component of the beam exiting the neutralizer cell of the beamline. The unneutralized full energy ions exiting the neutralizer are deflected from the beam path and the electrons in the cell are blocked by a magnetic field applied transverse to the beamline in the cell exit region. The ions, which are generated at essentially ground potential and accelerated through the neutralizer cell by a negative acceleration voltage, are collected at ground potential. A neutralizer cell exit end region is provided which allows the magnetic and electric fields acting on the exiting ions to be closely coupled. As a result, the fractional energy ions exiting the cell with the full energy ions are reflected back into the gas cell. Thus, the fractional energy ions do not detract from the energy recovery efficiency of full energy ions exiting the cell which can reach the ground potential interior surfaces of the beamline housing.

  20. Ion Sources for MedAustron

    CERN Document Server

    Lettry, J; Wallner, J; Sargsyan, E; CERN. Geneva. BE Department

    2010-01-01

    The MedAustron Ion therapy center will be constructed in Wiener Neustadt (Austria) in the vicinity of Vienna. Its accelerator complex consists of four ion sources, a linear accelerator, a synchrotron and a beam delivery system to the three medical treatment rooms and to the research irradiation room. The ion sources shall deliver beams of H31+, C4+ and light ions with utmost reliability and stability. This paper describes the features of the ion sources presently planned for the MedAustron facility; such as ion source main parameters, gas injection, temperature control and cooling systems. A dedicated beam diagnostics technique is proposed in order to characterize ECR ions beams; in the first drift region after the ion source, a fraction of the mixed beam is selected via moveable aperture. With standard beam diagnostics, we then aim to produce position-dependant observables such as ion-current density, beam energy distribution and emittance for each charge states to be compared to simulations of ECR e-heating...

  1. Lithium-ion batteries fundamentals and applications

    CERN Document Server

    Wu, Yuping

    2015-01-01

    Lithium-Ion Batteries: Fundamentals and Applications offers a comprehensive treatment of the principles, background, design, production, and use of lithium-ion batteries. Based on a solid foundation of long-term research work, this authoritative monograph:Introduces the underlying theory and history of lithium-ion batteriesDescribes the key components of lithium-ion batteries, including negative and positive electrode materials, electrolytes, and separatorsDiscusses electronic conductive agents, binders, solvents for slurry preparation, positive thermal coefficient (PTC) materials, current col

  2. Ion thruster charge-exchange plasma flow

    Science.gov (United States)

    Carruth, M. R., Jr.; Gabriel, S. B.; Kitamura, S.

    1982-01-01

    The electron bombardment ion thruster has been under development for a number of years and during this time, studies of the plasmas produced by the thrusters and their interactions with spacecraft have been evaluated, based on available data. Due to diagnostic techniques used and facility effects, there is uncertainty as to the reliability of data from these early studies. This paper presents data on the flow of the charge-exchange plasma produced just downstream of the thruster's ion optics. The 'end-effect' of a cylindrical Langmuir probe is used to determine ion density and directed ion velocity. Results are compared with data obtained from a retarding potential analyzer-Faraday cup.

  3. Plasma immersion ion implantation for reducing metal ion release

    Energy Technology Data Exchange (ETDEWEB)

    Diaz, C.; Garcia, J. A.; Maendl, S.; Pereiro, R.; Fernandez, B.; Rodriguez, R. J. [Centro de Ingenieria Avanzada de Superficies AIN, 31191, Cordovilla-Pamplona (Spain); Leibniz-Institut fuer Oberflaechenmodifizierung, 04318 Leipzig (Germany); Universidad de Oviedo, Departamento Quimica Fisica y Analitica (Spain); Centro de Ingenieria Avanzada de Superficies AIN, 31191, Cordovilla-Pamplona (Spain)

    2012-11-06

    Plasma immersion ion implantation of Nitrogen and Oxygen on CoCrMo alloys was carried out to improve the tribological and corrosion behaviors of these biomedical alloys. In order to optimize the implantation results we were carried experiments at different temperatures. Tribocorrosion tests in bovine serum were used to measure Co, Cr and Mo releasing by using Inductively Coupled Plasma Mass Spectrometry analysis after tests. Also, X-ray Diffraction analysis were employed in order to explain any obtained difference in wear rate and corrosion tests. Wear tests reveals important decreases in rate of more than one order of magnitude for the best treatment. Moreover decreases in metal release were found for all the implanted samples, preserving the same corrosion resistance of the unimplanted samples. Finally this paper gathers an analysis, in terms of implantation parameters and achieved properties for industrial implementation of these treatments.

  4. An ion guide laser ion source for isobar-suppressed rare isotope beams

    Energy Technology Data Exchange (ETDEWEB)

    Raeder, Sebastian, E-mail: sebastian.raeder@fys.kuleuven.be; Ames, Friedhelm; Bishop, Daryl; Bricault, Pierre; Kunz, Peter; Mjøs, Anders [TRIUMF, 4004 Wesbrook Mall, Vancouver, British Columbia V6T 2A3 (Canada); Heggen, Henning, E-mail: heggen@triumf.ca [TRIUMF, 4004 Wesbrook Mall, Vancouver, British Columbia V6T 2A3 (Canada); Institute of Applied Physics, TU Darmstadt, Schlossgartenstr. 7, 64289 Darmstadt (Germany); Lassen, Jens, E-mail: lassen@triumf.ca; Teigelhöfer, Andrea [TRIUMF, 4004 Wesbrook Mall, Vancouver, British Columbia V6T 2A3 (Canada); Department of Physics and Astronomy, University of Manitoba, Winnipeg, Manitoba R3T 2N2 (Canada)

    2014-03-15

    Modern experiments at isotope separator on-line (ISOL) facilities like ISAC at TRIUMF often depend critically on the purity of the delivered rare isotope beams. Therefore, highly selective ion sources are essential. This article presents the development and successful on-line operation of an ion guide laser ion source (IG-LIS) for the production of ion beams free of isobaric contamination. Thermionic ions from the hot ISOL target are suppressed by an electrostatic potential barrier, while neutral radio nuclides effusing out are resonantly ionized by laser radiation within a quadrupole ion guide behind this barrier. The IG-LIS was developed through detailed thermal and ion optics simulation studies and off-line tests with stable isotopes. In a first on-line run with a SiC target a suppression of surface-ionized Na contaminants in the ion beam of up to six orders of magnitude was demonstrated.

  5. Ion hole formation and nonlinear generation of electromagnetic ion cyclotron waves: THEMIS observations

    Science.gov (United States)

    Shoji, Masafumi; Miyoshi, Yoshizumi; Katoh, Yuto; Keika, Kunihiro; Angelopoulos, Vassilis; Kasahara, Satoshi; Asamura, Kazushi; Nakamura, Satoko; Omura, Yoshiharu

    2017-09-01

    Electromagnetic plasma waves are thought to be responsible for energy exchange between charged particles in space plasmas. Such an energy exchange process is evidenced by phase space holes identified in the ion distribution function and measurements of the dot product of the plasma wave electric field and the ion velocity. We develop a method to identify ion hole formation, taking into consideration the phase differences between the gyromotion of ions and the electromagnetic ion cyclotron (EMIC) waves. Using this method, we identify ion holes in the distribution function and the resulting nonlinear EMIC wave evolution from Time History of Events and Macroscale Interactions during Substorms (THEMIS) observations. These ion holes are key to wave growth and frequency drift by the ion currents through nonlinear wave-particle interactions, which are identified by a computer simulation in this study.

  6. Motion of negative ion plasma near the boundary with electron−ion plasma

    Energy Technology Data Exchange (ETDEWEB)

    Medvedev, Yu. V., E-mail: medve@mail.ru [Russian Academy of Sciences, Joint Institute for High Temperatures (Russian Federation)

    2017-01-15

    Processes occurring near the boundary between three-component plasma with negative ions and two-component electron−ion plasma are considered. The excited waves and instability are described. Stability condition at the boundary is determined.

  7. Production of High Energy Ions Near an Ion Thruster Discharge Hollow Cathode

    Science.gov (United States)

    Katz, Ira; Mikellides, I. G.; Goebel, D. M.; Jameson, K. K.; Wirz, R.; Polk, James E.

    2006-01-01

    Several researchers have measured ions leaving ion thruster discharge chambers with energies far greater than measured discharge chamber potentials. Presented in this paper is a new mechanism for the generation of high energy ions and a comparison with measured ion spectra. The source of high energy ions has been a puzzle because they not only have energies in excess of measured steady state potentials, but as reported by Goebel et. al. [1], their flux is independent of the amplitude of time dependent plasma fluctuations. The mechanism relies on the charge exchange neutralization of xenon ions accelerated radially into the potential trough in front of the discharge cathode. Previous researchers [2] have identified the importance of charge exchange in this region as a mechanism for protecting discharge cathode surfaces from ion bombardment. This paper is the first to identify how charge exchange in this region can lead to ion energy enhancement.

  8. Hybrid Lithium-ion Capacitor / Lithium-ion Battery System for Extended Performance Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The work focused on testing the Li-ion supercapacitors to confirm their performance and safety.  The li-ion supercaps were found to be safe under several...

  9. Simulation of Electric Potentials and Ion Motion in Planar Electrode Structures for Lossless Ion Manipulations (SLIM)

    OpenAIRE

    Garimella, Sandilya V.B.; Ibrahim, Yehia M.; Webb, Ian K.; Tolmachev, Aleksey V.; Zhang, Xinyu; Prost, Spencer A; Anderson, Gordon A.; Smith, Richard D.

    2014-01-01

    We report a conceptual study and computational evaluation of novel planar electrode Structures for Lossless Ion Manipulations (SLIM). Planar electrode SLIM devices were designed that allow for flexible ion confinement, transport and storage using a combination of RF and DC fields. Effective potentials can be generated that provide near ideal regions for confining and manipulating ions in the presence of a gas. Ion trajectory simulations using SIMION 8.1 demonstrated the capability for lossles...

  10. Carbon Mineralization Using Phosphate and Silicate Ions

    Science.gov (United States)

    Gokturk, H.

    2013-12-01

    Carbon dioxide (CO2) reduction from combustion of fossil fuels has become an urgent concern for the society due to marked increase in weather related natural disasters and other negative consequences of global warming. CO2 is a highly stable molecule which does not readily interact with other neutral molecules. However it is more responsive to ions due to charge versus quadrupole interaction [1-2]. Ions can be created by dissolving a salt in water and then aerosolizing the solution. This approach gives CO2 molecules a chance to interact with the hydrated salt ions over the large surface area of the aerosol. Ion containing aerosols exist in nature, an example being sea spray particles generated by breaking waves. Such particles contain singly and doubly charged salt ions including Na+, Cl-, Mg++ and SO4--. Depending on the proximity of CO2 to the ion, interaction energy can be significantly higher than the thermal energy of the aerosol. For example, an interaction energy of 0.6 eV is obtained with the sulfate (SO4--) ion when CO2 is the nearest neighbor [2]. In this research interaction between CO2 and ions which carry higher charges are investigated. The molecules selected for the study are triply charged phosphate (PO4---) ions and quadruply charged silicate (SiO4----) ions. Examples of salts which contain such molecules are potassium phosphate (K3PO4) and sodium orthosilicate (Na4SiO4). The research has been carried out with first principle quantum mechanical calculations using the Density Functional Theory method with B3LYP functional and Pople type basis sets augmented with polarization and diffuse functions. Atomic models consist of the selected ions surrounded by water and CO2 molecules. Similar to the results obtained with singly and doubly charged ions [1-2], phosphate and silicate ions attract CO2 molecules. Energy of interaction between the ion and CO2 is 1.6 eV for the phosphate ion and 3.3 eV for the silicate ion. Hence one can expect that the selected

  11. Anomalous ion thermal transport in hot ion plasmas by the ion temperature gradient mode

    Energy Technology Data Exchange (ETDEWEB)

    Kim, J.Y.; Horton, W. (Texas Univ., Austin, TX (United States). Inst. for Fusion Studies); Coppi, B. (Massachusetts Inst. of Tech., Cambridge, MA (United States). Research Lab. of Electronics)

    1992-01-01

    Experiments show that the observed radial profiles of the ion thermal conductivity {chi}{sub i} have the opposite shapes with those obtained from the ion temperature gradient mode ({eta}{sub i} mode) turbulence model by the traditional mixing length estimate. In this work, this radial profile problem is reconsidered with an electromagnetic study of the linear stability of the toroidal {eta}{sub i} mode and a new rule for choosing the mixing length. It is first shown that the electromagnetic effect gives a significant stabilizing effect on the toroidal {eta}{sub i} mode, and that the observed reduction of {chi}{sub i}(r) in the core region can be explained by this electromagnetic effect. Secondly, in view of earlier numerical simulations showing the transfer of fluctuation energy to larger scales that those for the fastest growth rate, as well as fluctuation measurements indicating longer radial correlation lengths, a new mixing length formula is proposed to explain the radial increase of the {chi}{sub i}. It is shown the new formula fits well the observed {chi}{sub i}(r) profiles in two TFTR supershot discharges and also gives the scaling law in the current and the magnetic field which agrees better with experiment than the conventional formula.

  12. Anomalous ion thermal transport in hot ion plasmas by the ion temperature gradient mode

    Energy Technology Data Exchange (ETDEWEB)

    Kim, J.Y.; Horton, W. [Texas Univ., Austin, TX (United States). Inst. for Fusion Studies; Coppi, B. [Massachusetts Inst. of Tech., Cambridge, MA (United States). Research Lab. of Electronics

    1992-08-01

    Experiments show that the observed radial profiles of the ion thermal conductivity {chi}{sub i} have the opposite shapes with those obtained from the ion temperature gradient mode ({eta}{sub i} mode) turbulence model by the traditional mixing length estimate. In this work, this radial profile problem is reconsidered with an electromagnetic study of the linear stability of the toroidal {eta}{sub i} mode and a new rule for choosing the mixing length. It is first shown that the electromagnetic effect gives a significant stabilizing effect on the toroidal {eta}{sub i} mode, and that the observed reduction of {chi}{sub i}(r) in the core region can be explained by this electromagnetic effect. Secondly, in view of earlier numerical simulations showing the transfer of fluctuation energy to larger scales that those for the fastest growth rate, as well as fluctuation measurements indicating longer radial correlation lengths, a new mixing length formula is proposed to explain the radial increase of the {chi}{sub i}. It is shown the new formula fits well the observed {chi}{sub i}(r) profiles in two TFTR supershot discharges and also gives the scaling law in the current and the magnetic field which agrees better with experiment than the conventional formula.

  13. ANALYSIS OF FERRIC AND FERROUS IONS IN SOIL EXTRACTS BY ION CHROMATOGRAPHY

    Science.gov (United States)

    A method using ion chromatography (IC) for the analysis of ferrous (Fe 2+) and ferric (Fe 3+) ions in soil extracts has been developed. This method uses an ion exchange column with detection at 520 nm after post-column derivatization. Selectivity is achieved by using an anionic...

  14. Review on heavy ion radiotherapy facilities and related ion sources (invited)

    NARCIS (Netherlands)

    Kitagawa, A.; Fujita, T.; Muramatsu, M.; Biri, S.; Drentje, A. G.

    Heavy ion radiotherapy awakens worldwide interest recently. The clinical results obtained by the Heavy Ion Medical Accelerator in Chiba at the National Institute of Radiological Sciences in Japan have clearly demonstrated the advantages of carbon ion radiotherapy. Presently, there are four

  15. The use and development of ion dispensers for laser-cooled atomic ion experiments

    Science.gov (United States)

    Hucul, David; Christensen, Justin E.; Hudson, Eric R.; Campbell, Wesley C.

    2017-04-01

    Fast, reliable, efficient loading of ions in ion traps is important for laser cooled ion trapping experiments. We utilize a simple surface ionization technique where ions are directly emitted from a platinum surface upon sublimation. This technique of direct ion production has wide applicability to ion trapping experiments and should apply to the direct production of positively charged atomic and molecular species as well as molecular anions. We experimentally demonstrate the ease and flexibility of this technique by directly producing calcium, strontium, cesium, barium, and potassium ions from a heated platinum surface. In addition, this technique is useful for loading rare isotopes into an ion trap. We experimentally demonstrate this by loading large numbers barium ions into an ion trap and distilling rare, isotopically pure ion chains through voltage control and laser heating and cooling. These techniques are directly applicable to the loading of 133Ba+ ions, a candidate qubit that combines the favorable atomic structure of 171Yb+, long-lived metastable states to ensure high fidelity detection, and visible optical transitions to leverage existing optical technologies.

  16. Nonplanar ion-acoustic shocks in electron–positron–ion plasmas ...

    Indian Academy of Sciences (India)

    Home; Journals; Pramana – Journal of Physics; Volume 81; Issue 3. Nonplanar ion-acoustic shocks in ... The influence of other plasma parameters such as, ion kinematic viscosity and ion temperature, is discussed in the presence of superthermal electrons in nonplanar geometry. It is also seen that the IASWs propagating in ...

  17. Isotopic anomaly for carbon ions in an electron cyclotron resonance ion source

    NARCIS (Netherlands)

    Drentje, A. G.; Kitagawa, A.; Muramatsu, M.

    In many experiments methods were applied to increase the highly charged ion output from an electron cyclotron resonance ion source; the gas-mixing method is still generally being applied. The dominant role of the masses of the ions in the gas-mixture was apparent. Two basically differing mechanisms

  18. Stability of electrostatic ion cyclotron waves in a multi-ion plasma†

    Indian Academy of Sciences (India)

    Abstract. We have studied the stability of the electrostatic ion cyclotron wave in a plasma consisting of isotropic hydrogen ions (H+) and temperature-anisotropic positively. (O+) and negatively (O−) charged oxygen ions, with the electrons drifting parallel to the magnetic field. Analytical expressions have been derived for the ...

  19. Indium Single-Ion Frequency Standard

    Science.gov (United States)

    Nagourney, Warren

    2001-01-01

    A single laser-cooled indium ion is a promising candidate for an ultimate resolution optical time or frequency standard. It can be shown that single ions from group IIIA of the periodic table (indium, thallium, etc.) can have extremely small systematic errors. In addition to being free from Doppler, transit-time and collisional shifts, these ions are also quite insensitive to perturbations from ambient magnetic and electric fields (mainly due to the use of a J=0-0 transition for spectroscopy). Of all group IIIA ions, indium seems to be the most practical, since it is heavy enough to have a tolerable intercombination cooling transition rate and (unlike thallium) has transitions which are easily accessible with frequency multiplied continuous-wave lasers. A single indium ion standard has a potential inaccuracy of one part in 10(exp 18) for integration times of 10(exp 6) seconds. We have made substantial progress during the grant period in constructing a frequency standard based upon a single indium ion. At the beginning of the grant period, single indium ions were being successfully trapped, but the lasers and optical systems were inadequate to achieve the desired goal. We have considerably improved the stability of the dye laser used to cool the ions and locked it to a molecular resonance line, making it possible to observe stable cooling-line fluorescence from a single indium ion for reasonable periods of time, as required by the demands of precision spectroscopy. We have substantially improved the single-ion fluorescence signal with significant benefits for the detection efficiency of forbidden transitions using the 'shelving' technique. Finally, we have constructed a compact, efficient UV 'clock' laser and observed 'clock' transitions in single indium ions using this laser system. We will elaborate on these accomplishments.

  20. Aligned ion implementation using scanning probes

    Energy Technology Data Exchange (ETDEWEB)

    Persaud, A.

    2006-12-12

    A new technique for precision ion implantation has been developed. A scanning probe has been equipped with a small aperture and incorporated into an ion beamline, so that ions can be implanted through the aperture into a sample. By using a scanning probe the target can be imaged in a non-destructive way prior to implantation and the probe together with the aperture can be placed at the desired location with nanometer precision. In this work first results of a scanning probe integrated into an ion beamline are presented. A placement resolution of about 120 nm is reported. The final placement accuracy is determined by the size of the aperture hole and by the straggle of the implanted ion inside the target material. The limits of this technology are expected to be set by the latter, which is of the order of 10 nm for low energy ions. This research has been carried out in the context of a larger program concerned with the development of quantum computer test structures. For that the placement accuracy needs to be increased and a detector for single ion detection has to be integrated into the setup. Both issues are discussed in this thesis. To achieve single ion detection highly charged ions are used for the implantation, as in addition to their kinetic energy they also deposit their potential energy in the target material, therefore making detection easier. A special ion source for producing these highly charged ions was used and their creation and interactions with solids of are discussed in detail. (orig.)

  1. Resonant ion transport in EBT

    Energy Technology Data Exchange (ETDEWEB)

    Hastings, D.E.; Jaeger, E.F.; Hedrick, C.L.; Tolliver, J.S.

    1983-05-01

    We use a model for the ELMO Bumpy Torus as a bumpy cylinder with a toroidally induced vertical drift imposed on the plasma. With this model we obtain the neoclassical plasma-transport coefficients for ions in both the banana and plateau resonant regimes. The problem of solving the linearized bounce-averaged drift kinetic equation is formulated as a variational principle, which is shown to be valid for both the banana and plateau regimes. We use limiting forms of this principle to obtain a continuous collisionality approximation to the energy-dependent flux. We then use this approximation to obtain analytic formulae for the particle- and energy-diffusion coefficients. These are shown to give excellent agreement with numerical results.

  2. Pervaporation with ion exchange membranes

    Energy Technology Data Exchange (ETDEWEB)

    Boeddeker, K.W.; Wenzlaff, A.

    1986-01-01

    Sorption and pervaporation of aqueous-organic solvent systems (water-ethanol; water-carboxylic acids) with commercial ion exchange membranes are compared to obtain information on polymersolvent interaction vs. coupling. Close agreement between sorption selectivity and pervaporation selectivity indicates coupling. If pervaporation is less selective than sorption, polymer-solvent interaction overtakes coupling, the limit of de-coupling being phase separation within the sorbate as signaled by a sudden increase in permeability of the lesser interacting component. As long as sorption and pervaporation operate in parallel, favoring enrichment of the same component, coupling enhances the separation effect. If pervaporation counteracts sorption, coupling is detrimental to the separation effect. Potential applications include the dehydration of pre-concentrated water-ethanol using anion exchange membranes, and the enrichment of acetic acid from dilute aqueous solution by pervaporative removal of water through cation exchange membranes.

  3. QCD in heavy ion collisions

    CERN Document Server

    Iancu, Edmond

    2014-04-10

    These lectures provide a modern introduction to selected topics in the physics of ultrarelativistic heavy ion collisions which shed light on the fundamental theory of strong interactions, the Quantum Chromodynamics. The emphasis is on the partonic forms of QCD matter which exist in the early and intermediate stages of a collision -- the colour glass condensate, the glasma, and the quark-gluon plasma -- and on the effective theories that are used for their description. These theories provide qualitative and even quantitative insight into a wealth of remarkable phenomena observed in nucleus-nucleus or deuteron-nucleus collisions at RHIC and/or the LHC, like the suppression of particle production and of azimuthal correlations at forward rapidities, the energy and centrality dependence of the multiplicities, the ridge effect, the limiting fragmentation, the jet quenching, or the dijet asymmetry.

  4. Ions in hyaluronic acid solutions

    Science.gov (United States)

    Horkay, Ferenc; Basser, Peter J.; Londono, David J.; Hecht, Anne-Marie; Geissler, Erik

    2009-11-01

    Hyaluronic acid (HA) is an anionic biopolymer that is almost ubiquitous in biological tissues. An attempt is made to determine the dominant features that account for both its abundance and its multifunctional role, and which set it apart from other types of biopolymers. A combination of osmotic and scattering techniques is employed to quantify its dynamic and static properties in near-physiological solution conditions, where it is exposed both to mono- and divalent counterions. An equation of state is derived for the osmotic pressure Π in the semidilute concentration region, in terms of two variables, the polymer concentration c and the ionic strength J of the added salt, according to which Π =1.4×103c9/4/J3/4 kPa, where c and J are expressed in mole. Over the physiological ion concentration range, the effect of the sodium chloride and calcium chloride on the osmotic properties of HA solutions is fully accounted for by their contributions to the ionic strength. The absence of precipitation, even at high CaCl2 concentrations, distinguishes this molecule from other biopolymers such as DNA. Dynamic light scattering measurements reveal that the collective diffusion coefficient in HA solutions exceeds that in aqueous solutions of typical neutral polymers by a factor of approximately 5. This property ensures rapid adjustment to, and recovery from, stress applied to HA-containing tissue. Small angle x-ray scattering measurements confirm the absence of appreciable structural reorganization over the observed length scale range 10-1000 Å, as a result of calcium-sodium ion exchange. The scattered intensity in the transfer momentum range q >0.03 Å-1 varies as 1/q, indicating that the HA chain segments in semidilute solutions are linear over an extended concentration range. The osmotic compression modulus c ∂Π/∂c, a high value of which is a prerequisite in structural biopolymers, is several times greater than in typical neutral polymer solutions.

  5. Ion mass and energy selective hyperthermal ion-beam assisted deposition setup

    Science.gov (United States)

    Gerlach, J. W.; Schumacher, P.; Mensing, M.; Rauschenbach, S.; Cermak, I.; Rauschenbach, B.

    2017-06-01

    For the synthesis of high-quality thin films, ion-beam assisted deposition (IBAD) is a frequently used technique providing precise control over several substantial film properties. IBAD typically relies on the use of a broad-beam ion source. Such ion sources suffer from the limitation that they deliver a blend of ions with different ion masses, each of them possessing a certain distribution of kinetic energy. In this paper, a compact experimental setup is presented that enables the separate control of ion mass and ion kinetic energy in the region of hyperthermal energies (few 1 eV - few 100 eV). This ion energy region is of increasing interest not only for ion-assisted film growth but also for the wide field of preparative mass spectrometry. The setup consists of a constricted glow-discharge plasma beam source and a tailor-made, compact quadrupole system equipped with entry and exit ion optics. It is demonstrated that the separation of monoatomic and polyatomic nitrogen ions (N+ and N2+) is accomplished. For both ion species, the kinetic energy is shown to be selectable in the region of hyperthermal energies. At the sample position, ion current densities are found to be in the order of 1 μA/cm2 and the full width at half maximum of the ion beam profile is in the order of 10 mm. Thus, the requirements for homogeneous deposition processes in sufficiently short periods of time are fulfilled. Finally, employing the described setup, for the first time in practice epitaxial GaN films were deposited. This opens up the opportunity to fundamentally study the influence of the simultaneous irradiation with hyperthermal ions on the thin film growth in IBAD processes and to increase the flexibility of the technique.

  6. Specific ion effects on membrane potential and the permselectivity of ion exchange membranes

    KAUST Repository

    Geise, Geoffrey M.

    2014-08-26

    © the Partner Organisations 2014. Membrane potential and permselectivity are critical parameters for a variety of electrochemically-driven separation and energy technologies. An electric potential is developed when a membrane separates electrolyte solutions of different concentrations, and a permselective membrane allows specific species to be transported while restricting the passage of other species. Ion exchange membranes are commonly used in applications that require advanced ionic electrolytes and span technologies such as alkaline batteries to ammonium bicarbonate reverse electrodialysis, but membranes are often only characterized in sodium chloride solutions. Our goal in this work was to better understand membrane behaviour in aqueous ammonium bicarbonate, which is of interest for closed-loop energy generation processes. Here we characterized the permselectivity of four commercial ion exchange membranes in aqueous solutions of sodium chloride, ammonium chloride, sodium bicarbonate, and ammonium bicarbonate. This stepwise approach, using four different ions in aqueous solution, was used to better understand how these specific ions affect ion transport in ion exchange membranes. Characterization of cation and anion exchange membrane permselectivity, using these ions, is discussed from the perspective of the difference in the physical chemistry of the hydrated ions, along with an accompanying re-derivation and examination of the basic equations that describe membrane potential. In general, permselectivity was highest in sodium chloride and lowest in ammonium bicarbonate solutions, and the nature of both the counter- and co-ions appeared to influence measured permselectivity. The counter-ion type influences the binding affinity between counter-ions and polymer fixed charge groups, and higher binding affinity between fixed charge sites and counter-ions within the membrane decreases the effective membrane charge density. As a result permselectivity decreases. The

  7. Ion Beams in Nanoscience and Technology

    CERN Document Server

    Hellborg, Ragnar

    2010-01-01

    Energetic ion beam irradiation is the basis of a wide plethora of powerful research- and fabrication-techniques for materials characterisation and processing on a nanometre scale. This book is suitable for practitioners, researchers and graduate students working in the field of ion beams and application

  8. METAL ION SEQUESTRATION: AN EXCITING DIMENSION FOR ...

    African Journals Online (AJOL)

    ABSTRACT. The use of a tight binding macrocyclic ligand to complex a metal ion so that this serves as receptee on the Molecularly Imprinted Polymer (MIP) receptor as described here affords a sequestration route for a targeted metal ion, with potential for environmental remediation and restoration applications. Ethylene ...

  9. High Rate Performing Li-ion Battery

    Science.gov (United States)

    2015-02-09

    permeable to lithium ions and efficient in transferring the electrons into/from the LVP surface to the corresponding current collector. a) b) c) d) e...PO4)3/C for High Rate Lithium-ion Battery Applications”, Lee Hwang Sheng, Nail Suleimanov, Vishwanathan Ramar, Mangayarkarasi Murugan, Kuppan

  10. The Holyfield heavy ion research facility

    Science.gov (United States)

    Jones, C. M.; Alton, G. D.; Ball, J. B.; Biggerstaff, J. A.; Dowling, D. T.; Erb, K. A.; Haynes, D. L.; Hoglund, D. E.; Hudson, E. D.; Juras, R. C.; Lane, S. N.; Ludemann, C. A.; Martin, J. A.; Meigs, M. J.; Mosko, S. W.; Olsen, D. K.; Ziegler, N. F.

    1988-05-01

    Development of the Holifield facility has continued with resulting improvements in the number of ion species provided, in the ion energy for tandem-only operations, and in utilization efficiency. In this report, we describe our recent operational experience, development activities, and future development plans.

  11. The Holifield Heavy Ion Research Facility

    Energy Technology Data Exchange (ETDEWEB)

    Jones, C.M.; Alton, G.D.; Ball, J.B.; Biggerstaff, J.A.; Dowling, D.T.; Erb, K.A.; Haynes, D.L.; Hoglund, D.E.; Hudson, E.D.; Juras, R.C.

    1987-01-01

    Development of the Holified facility has continued with resulting improvements in the number of ion species provided, ion energy for tandem-only operations, and utilization efficiency. In this report, we describe our recent operational experience, development activities, and future development plans.

  12. Resonant coherent excitation of channeled ions

    Energy Technology Data Exchange (ETDEWEB)

    Datz, S.; Moak, C.D.; Crawford, O.H.; Krause, H.F.; Dittner, P.F.; Gomez del Campo, J.; Biggerstaff, J.A.; Miller, P.D.; Hvelplund, P.; Knudsen, H.

    1978-03-27

    We have observed resonant excitation of swift channeled hydrogenlike ions (Z = 5 to Z = 9) and heliumlike F/sup 7 +/ which arises from a coherent periodic perturbation by the atoms in the bounding crystal rows. The resonance excitation was seen through the reduction in the transmission of fixed-charge-state ions through channels in thin crystals of Au and Ag.

  13. Scaffold Diversity from N-Acyliminium Ions

    DEFF Research Database (Denmark)

    Wu, Peng; Nielsen, Thomas E

    2017-01-01

    N-Acyliminium ions are powerful reactive species for the formation of carbon-carbon and carbon-heteroatom bonds. Strategies relying on intramolecular reactions of N-acyliminium intermediates, also referred to as N-acyliminium ion cyclization reactions, have been employed for the construction of s......, covering the literature over the past 12 years (from 2004 to 2015)....

  14. Changes in ion transport in inflammatory disease

    Directory of Open Access Journals (Sweden)

    Eisenhut Michael

    2006-03-01

    Full Text Available Abstract Ion transport is essential for maintenance of transmembranous and transcellular electric potential, fluid transport and cellular volume. Disturbance of ion transport has been associated with cellular dysfunction, intra and extracellular edema and abnormalities of epithelial surface liquid volume. There is increasing evidence that conditions characterized by an intense local or systemic inflammatory response are associated with abnormal ion transport. This abnormal ion transport has been involved in the pathogenesis of conditions like hypovolemia due to fluid losses, hyponatremia and hypokalemia in diarrhoeal diseases, electrolyte abnormalites in pyelonephritis of early infancy, septicemia induced pulmonary edema, and in hypersecretion and edema induced by inflammatory reactions of the mucosa of the upper respiratory tract. Components of membranous ion transport systems, which have been shown to undergo a change in function during an inflammatory response include the sodium potassium ATPase, the epithelial sodium channel, the Cystic Fibrosis Transmembrane Conductance Regulator and calcium activated chloride channels and the sodium potassium chloride co-transporter. Inflammatory mediators, which influence ion transport are tumor necrosis factor, gamma interferon, interleukins, transforming growth factor, leukotrienes and bradykinin. They trigger the release of specific messengers like prostaglandins, nitric oxide and histamine which alter ion transport system function through specific receptors, intracellular second messengers and protein kinases. This review summarizes data on in vivo measurements of changes in ion transport in acute inflammatory conditions and in vitro studies, which have explored the underlying mechanisms. Potential interventions directed at a correction of the observed abnormalities are discussed.

  15. Formation of Ion Phase-Space Vortexes

    DEFF Research Database (Denmark)

    Pécseli, Hans; Trulsen, J.; Armstrong, R. J.

    1984-01-01

    for their initial evolution is derived. The results are supported by a numerical particle simulation. Also the possibility of vortex excitation by ion bursts and coalescence of two vortexes are demonstrated. The effects of finite ion temperature, particle trapping and charge exchange collisions are discussed...

  16. On Collisionless Damping of Ion Acoustic Waves

    DEFF Research Database (Denmark)

    Jensen, Vagn Orla; Petersen, P.I.

    1973-01-01

    Exact theoretical treatments show that the damping of ion acoustic waves in collisionless plasmas does not vanish when the derivative of the undisturbed distribution function at the phase velocity equals zero.......Exact theoretical treatments show that the damping of ion acoustic waves in collisionless plasmas does not vanish when the derivative of the undisturbed distribution function at the phase velocity equals zero....

  17. Dynamic electrochemical measurement of chloride ions

    NARCIS (Netherlands)

    Abbas, Yawar; de Graaf, Derk B.; Olthuis, Wouter; van den Berg, Albert

    2016-01-01

    This protocol describes the dynamic measurement of chloride ions using the transition time of a silver silver chloride (Ag/AgCl) electrode. Silver silver chloride electrode is used extensively for potentiometric measurement of chloride ions concentration in electrolyte. In this measurement,

  18. Hopping models for ion conduction in noncrystals

    DEFF Research Database (Denmark)

    Dyre, Jeppe; Schrøder, Thomas

    2007-01-01

    Ion conduction in noncrystals (glasses, polymers, etc) has a number of properties in common. In fact, from a purely phenomenological point of view, these properties are even more widely observed: ion conduction behaves much like electronic conduction in disordered materials (e.g., amorphous semic...

  19. Relativistic heavy-ion physics: Experimental overview

    Indian Academy of Sciences (India)

    Abstract. The field of relativistic heavy-ion physics is reviewed with emphasis on new results and highlights from the first run of the relativistic heavy-ion collider at BNL and the 15 year research programme at the super proton synchrotron (SPS) at CERN and the AGS at BNL.

  20. Electron-cyclotron-resonance ion sources (review)

    Energy Technology Data Exchange (ETDEWEB)

    Golovanivskii, K.S.; Dougar-Jabon, V.D. [People`s Friendship Univ., Moscow (Russian Federation)

    1992-01-01

    The physical principles are described and a brief survey of the present state is given of ion sources based on electron-cyclotron heating of plasma in a mirror trap. The characteristics of ECR sources of positive and negative ions used chiefly in accelerator technology are presented. 20 refs., 10 figs., 3 tabs.

  1. INFRARED AND RAMAN SPECTROSCOPIC STUDY OF ION ...

    African Journals Online (AJOL)

    Infrared and Raman spectroscopy techniques have been used to study the ionic interactions of strontium(II) and barium(II) with thiocyanate ion in liquid ammonia. A number of bands were observed in both n (CN) and n (CS) regions of infrared and Raman spectra and these were assigned to 1:1 contact ion pair, ...

  2. Ion speciation in milk-like systems

    NARCIS (Netherlands)

    Gao, R.

    2010-01-01

    The research described in this thesis is about ion behaviour in milk systems as a function of changing conditions (pH, ionic strength, addition of electrolytes and non-electrolytes). The focus was on (i) quantification of the ion equilibria in milk systems based on experimental conditions, (ii)

  3. The negative ions emission in nitrogen

    Science.gov (United States)

    Soon, W. H.; Kunc, J. A.

    1991-01-01

    The contribution of negative atomic ions to continuum radiation in nitrogen plasma is discussed. It is shown that both unstable N(-)(3P) and metastable N(-)(1D) ions have a significant effect on the total production of the continuum radiation at electron temperatures below 12,000 K.

  4. OGO 6 ion concentration irregularity studies

    Science.gov (United States)

    Mcclure, J. P.

    1973-01-01

    Research is reported concerning the ionospheric F-region irregularities. The results are based on in-situ OGO-6 measurements of the total ion concentration N sub i. A proposed mechanism for the generation of equatorial F-region irregularities and the morphological results, and the occurrence of Fe(+) ions in the equatorial F-region are discussed. Related research papers are included.

  5. Beam halo collimation in heavy ion synchrotrons

    Directory of Open Access Journals (Sweden)

    I. Strašík

    2015-08-01

    Full Text Available This paper presents a systematic study of the halo collimation of ion beams from proton up to uranium in synchrotrons. The projected Facility for Antiproton and Ion Research synchrotron SIS100 is used as a reference case. The concepts are separated into fully stripped (e.g., ^{238}U^{92+} and partially stripped (e.g., ^{238}U^{28+} ion collimation. An application of the two-stage betatron collimation system, well established for proton accelerators, is intended also for fully stripped ions. The two-stage system consists of a primary collimator (a scattering foil and secondary collimators (bulky absorbers. Interaction of the particles with the primary collimator (scattering, momentum losses, and nuclear interactions was simulated by using fluka. Particle-tracking simulations were performed by using mad-x. Finally, the dependence of the collimation efficiency on the primary ion species was determined. The influence of the collimation system adjustment, lattice imperfections, and beam parameters was estimated. The concept for the collimation of partially stripped ions employs a thin stripping foil in order to change their charge state. These ions are subsequently deflected towards a dump location using a beam optical element. The charge state distribution after the stripping foil was obtained from global. The ions were tracked by using mad–x.

  6. Ion exchange in the nuclear industry

    Energy Technology Data Exchange (ETDEWEB)

    Bibler, J.P.

    1990-12-31

    Ion exchange is used in nearly every part of the nuclear fuel cycle -- from the purification of uranium from its ore to the final recovery of uranium and transmutation products. Ion exchange also plays a valuable role in the management of nuclear wastes generated in the fuel cycle.

  7. Ion exchange in the nuclear industry

    Energy Technology Data Exchange (ETDEWEB)

    Bibler, J.P.

    1990-01-01

    Ion exchange is used in nearly every part of the nuclear fuel cycle -- from the purification of uranium from its ore to the final recovery of uranium and transmutation products. Ion exchange also plays a valuable role in the management of nuclear wastes generated in the fuel cycle.

  8. Electrosorption of tetraalkylammonium ions on silver iodide

    NARCIS (Netherlands)

    Keizer, de A.

    1981-01-01

    The object of the present investigations was to study the ef fect of the adsorption of charged organic ions on electrically charged, solid-liquid interfaces. To that end, symmetrical quater nary ammonium ions were adsorbed on a silver iodide-electrolyte interface at various

  9. Semiconductor applications of plasma immersion ion implantation ...

    Indian Academy of Sciences (India)

    Many semiconductor integrated circuit manufacturing processes require high dose of implantation at very low energies. Conventional beam line ion implantation system suffers from low beam current at low energies, therefore, cannot be used economically for high dose applications. Plasma immersion ion implantation (PIII) ...

  10. Radioactive ions and atoms in superfluid helium

    NARCIS (Netherlands)

    Dendooven, P.G.; Purushothaman, S.; Gloos, K.; Aysto, J.; Takahashi, N.; Huang, W.; Harissopulos, S; Demetriou, P; Julin, R

    2006-01-01

    We are investigating the use of superfluid helium as a medium to handle and manipulate radioactive ions and atoms. Preliminary results on the extraction of positive ions from superfluid helium at temperatures close to 1 K are described. Increasing the electric field up to 1.2 kV/cm did not improve

  11. Metal Ion Controlled Polymorphism of a Peptide

    DEFF Research Database (Denmark)

    Hemmingsen, Lars Bo Stegeager; Jancso, Attila; Szunyogh, Daniel

    2011-01-01

    , …) in the peptide, and the ligand and structural preferences of the metal ion (in our studies Zn2+, Cd2+, Hg2+, Cu+/2+). Simultaneously, new species such as metal ion bridged ternary complexes or even oligomers may be formed. In recent previous studies we have observed similar polymorphism of zinc finger model...

  12. Production of negatively charged radioactive ion beams

    Science.gov (United States)

    Liu, Y.; Stracener, D. W.; Stora, T.

    2017-08-01

    Beams of short-lived radioactive nuclei are needed for frontier experimental research in nuclear structure, reactions, and astrophysics. Negatively charged radioactive ion beams have unique advantages and allow for the use of a tandem accelerator for post-acceleration, which can provide the highest beam quality and continuously variable energies. Negative ion beams can be obtained with high intensity and some unique beam purification techniques based on differences in electronegativity and chemical reactivity can be used to provide beams with high purity. This article describes the production of negative radioactive ion beams at the former holifield radioactive ion beam facility at Oak Ridge National Laboratory and at the CERN ISOLDE facility with emphasis on the development of the negative ion sources employed at these two facilities. ).

  13. Parametric variations of ion transport in TFTR

    Energy Technology Data Exchange (ETDEWEB)

    Scott, S.D. [Princeton Univ., NJ (United States). Plasma Physics Lab.; Barnes, C.W. [Los Alamos National Lab., NM (United States); Ernst, D. [Massachusetts Inst. of Tech., Cambridge, MA (United States)

    1993-03-18

    This paper is divided into three roughly independent sections. The first is a historical review of the twenty year history of experimental ion heat transport measurements from many tokamaks. The second is a study of ion heat transport in Ohmic TFTR plasmas which shows that {chi}i {approximately} {chi}e {approx} 15{chi}i{sup neo}. Thus, ion heat transport is demonstrated to be strongly anomalous even the absence of auxiliary heating. The third section describes the variation of {chi}i with local ion temperature in TFTR during auxiliary heating, with emphasis on characterizing the differecens between transport in the L-mode and supershot regimes. The results are consistent with the conjecture that improved ion energy confinement in supershot plasmas is caused by a high ratio of T{sub 1}/T{sub e}.

  14. High current pelletron for ion implantation

    Science.gov (United States)

    Schroeder, James B.

    1989-04-01

    Since 1984, when the first production MeV ion implanter (an NEC model MV-T30) went on-line, interest in versatile electrostatic accelerator systems for MeV ion implantation has grown. The systems use a negative ion source to inject a tandem megavolt accelerator. In early systems the 0.4 mA of charging current from the two Pelletron charging chains in the accelerator was sufficient for the low intensity of beams from the ion source. This 2-chain system, however, is no longer adequate for the much higher beam intensities from today's improved ion sources. A 4-chain charging system, which delivers 1.3 mA to the high voltage terminal, was developed and is in operation in new models of NEC S Series Pelletron accelerators. This paper describes the latest beam performance of 1 MV and 1.7 MV Pelletron accelerators with this new 4-chain charging system.

  15. Characteristics of MINI ECR ion source

    Energy Technology Data Exchange (ETDEWEB)

    Saitoh, Yuichi; Yokota, Watalu [Japan Atomic Energy Research Inst., Takasaki, Gunma (Japan). Takasaki Radiation Chemistry Research Establishment

    1997-03-01

    A very compact electron cyclotron resonance ion source (MINI ECR) was manufactured to extend available energy ranges of ion beams by applying multiply charged ions to electrostatic accelerators. The magnetic field to confine a plasma is formed only by small permanent magnets and the microwave power up to 15 W is generated by a compact transistor amplifier in order to install the ion source at a narrow high-voltage terminal where the electrical power feed is restricted. The magnet assembly is 12 cm in length and 11 cm in diameter, and forms a mirror field with the maximum strength of 0.55 T. The total power consumption of the source is below 160 W. The performance of the source was tested in a bench stand. The results of Ar, Xe, O, and N ion generation are reported in this paper. (author)

  16. Method and apparatuses for ion cyclotron spectrometry

    Science.gov (United States)

    Dahl, David A [Idaho Falls, ID; Scott, Jill R [Idaho Falls, ID; McJunkin, Timothy R [Idaho Falls, ID

    2012-03-06

    An ion cyclotron spectrometer may include a vacuum chamber that extends at least along a z-axis and means for producing a magnetic field within the vacuum chamber so that a magnetic field vector is generally parallel to the z-axis. The ion cyclotron spectrometer may also include means for producing a trapping electric field within the vacuum chamber. The trapping electric field may comprise a field potential that, when taken in cross-section along the z-axis, includes at least one section that is concave down and at least one section that is concave up so that ions traversing the field potential experience a net magnetron effect on a cyclotron frequency of the ions that is substantially equal to zero. Other apparatuses and a method for performing ion cyclotron spectrometry are also disclosed herein.

  17. Method and apparatus for ion cyclotron spectrometry

    Science.gov (United States)

    Dahl, David A [Idaho Falls, ID; Scott, Jill R [Idaho Falls, ID; McJunkin, Timothy R [Idaho Falls, ID

    2010-08-17

    An ion cyclotron spectrometer may include a vacuum chamber that extends at least along a z-axis and means for producing a magnetic field within the vacuum chamber so that a magnetic field vector is generally parallel to the z-axis. The ion cyclotron spectrometer may also include means for producing a trapping electric field within the vacuum chamber that includes at least a first section that induces a first magnetron effect that increases a cyclotron frequency of an ion and at least a second section that induces a second magnetron effect that decreases the cyclotron frequency of an ion. The cyclotron frequency changes induced by the first and second magnetron effects substantially cancel one another so that an ion traversing the at least first and second sections will experience no net change in cyclotron frequency.

  18. Ion implantation into concave polymer surface

    Energy Technology Data Exchange (ETDEWEB)

    Sakudo, N. [Kanazawa Institute of Technology, Advanced Materials R and D Center, 3-1 Yatsukaho, Matto, Hakusan, Ishikawa 924-0838 (Japan)]. E-mail: sakudo@neptune.kanazawa-it.ac.jp; Shinohara, T. [Kanazawa Institute of Technology, Advanced Materials R and D Center, 3-1 Yatsukaho, Matto, Hakusan, Ishikawa 924-0838 (Japan); Amaya, S. [Kanazawa Institute of Technology, Advanced Materials R and D Center, 3-1 Yatsukaho, Matto, Hakusan, Ishikawa 924-0838 (Japan); Endo, H. [Kanazawa Institute of Technology, Advanced Materials R and D Center, 3-1 Yatsukaho, Matto, Hakusan, Ishikawa 924-0838 (Japan); Okuji, S. [Lintec Corp., 5-14-42 Nishiki-cho, Warabi, Saitama 335-0005 (Japan); Ikenaga, N. [Japan Science and Technology Corp., Nomigun, Ishikawa 923-1121 (Japan)

    2006-01-15

    A new technique for ion implantation into concave surface of insulating materials is proposed and experimentally studied. The principle is roughly described by referring to modifying inner surface of a PET (polyethylene terephthalate) bottle. An electrode that is supplied with positive high-voltage pulses is inserted into the bottle. Both plasma formation and ion implantation are simultaneously realized by the same high-voltage pulses. Ion sheath with a certain thickness that depends on plasma parameters is formed just on the inner surface of the bottle. Since the plasma potential is very close to that of the electrode, ions from the plasma are accelerated in the sheath and implanted perpendicularly into the bottle's inner surface. Laser Raman spectroscopy shows that the inner surface of an ion-implanted PET bottle is modified into DLC (diamond-like carbon). Gas permeation measurement shows that gas-barrier property enhances due to the modification.

  19. Trapped individual ion at absolute zero temperature

    Science.gov (United States)

    Yu, Nan; Dehmelt, Hans; Nagourney, Warren

    1989-01-01

    Laser cooling and ion trapping have progressed to such an extent that one can now speak of realizing a confined atom at absolute zero temperature. In this short publication, we analyze an experiment toward such realization using a single Ba+ ion in a miniature rf trap. The Ba+ ion is first laser-cooled to the limit where the ion spends most of its time in the zero-point energy state. Then a test sequence allows one to verify whether or not the ion is actually in its zero-point state. The test sequence may also serve as a device for state selection of an atom at absolute zero temperature. PMID:16594054

  20. Dendritic ion channelopathy in acquired epilepsy

    Science.gov (United States)

    Poolos, Nicholas P.; Johnston, Daniel

    2012-01-01

    Summary Ion channel dysfunction or “channelopathy” is a proven cause of epilepsy in the relatively uncommon genetic epilepsies with Mendelian inheritance. But numerous examples of acquired channelopathy in experimental animal models of epilepsy following brain injury have also been demonstrated. Our understanding of channelopathy has grown due to advances in electrophysiology techniques that have allowed the study of ion channels in the dendrites of pyramidal neurons in cortex and hippocampus. The apical dendrites of pyramidal neurons comprise the vast majority of neuronal surface membrane area, and thus the majority of the neuronal ion channel population. Investigation of dendritic ion channels has demonstrated remarkable plasticity in ion channel localization and biophysical properties in epilepsy, many of which produce hyperexcitability and may contribute to the development and maintenance of the epileptic state. Here we review recent advances in dendritic physiology and cell biology, and their relevance to epilepsy. PMID:23216577

  1. Ion beams in semiconductor physics and technology

    Energy Technology Data Exchange (ETDEWEB)

    Kalbitzer, S. (Max-Planck-Inst. fuer Kernphysik, Heidelberg (Germany))

    1992-01-01

    The remarkable progress during the last two decades in semiconductor device technology is partly due to the introduction of ion beams as a key instrument for the modification and analysis of semiconductors. The basic reason is seen in the inherent electrical property of ion beams to be accurately controllable in energy, dose and species. The basic penetration and incorporation mechanisms in elemental and compound semiconductors have been explored and growing agreement between experiment and theory has rendered ion implantation a predictable tool. Similarly, the high analytic potential of nuclear reactions with ion beams has been steadily exploited and outstanding results have been achieved. Some basic milestones in the development of the ion beam techniques will be reviewed and future trends discussed. (orig.).

  2. ION SOURCE FOR A SINGLE PARTICLE ACCELERATOR

    Directory of Open Access Journals (Sweden)

    Tomas Matlocha

    2016-12-01

    Full Text Available This paper proposes a method to obtain very low beam current on the injection side of an particle accelerator. By using a combination of a well known ion source type and a short photo-emissive laser pulse, very low amount of ions can be created. The method could be used in the ion source of various types of the accelerators, where very low beam current is essential. The design is adapted to build a compact internal ion source and the dimensions of the device are adjusted to fit central region of the cyclotron U-120M. The functional parameters of the device are discussed and the ammount of the produced ions is estimated.

  3. Study on Coulomb explosions of ion mixtures

    CERN Document Server

    Boella, E; D'Angola, A; Coppa, G; Silva, L O

    2015-01-01

    The paper presents a theoretical work on the dynamics of Coulomb explosion for spherical nanoplasmas composed by two different ion species. Particular attention has been dedicated to study the energy spectra of the ions with the larger charge-to-mass ratio. The connection between the formation of shock shells and the energy spread of the ions has been the object of a detailed analysis, showing that under particular conditions the width of the asymptotic energy spectrum tends to become very narrow, which leads to a multi-valued ion phase-space. The conditions to generate a quasi mono-energetic ion spectrum have been rigorously demonstrated and verifed by numerical simulations, using a technique that, exploiting the spherical symmetry of the problem, allows one to obtain very accurate and precise results.

  4. Ion-induced electron emission microscopy

    Science.gov (United States)

    Doyle, Barney L.; Vizkelethy, Gyorgy; Weller, Robert A.

    2001-01-01

    An ion beam analysis system that creates multidimensional maps of the effects of high energy ions from an unfocussed source upon a sample by correlating the exact entry point of an ion into a sample by projection imaging of the secondary electrons emitted at that point with a signal from a detector that measures the interaction of that ion within the sample. The emitted secondary electrons are collected in a strong electric field perpendicular to the sample surface and (optionally) projected and refocused by the electron lenses found in a photon emission electron microscope, amplified by microchannel plates and then their exact position is sensed by a very sensitive X Y position detector. Position signals from this secondary electron detector are then correlated in time with nuclear, atomic or electrical effects, including the malfunction of digital circuits, detected within the sample that were caused by the individual ion that created these secondary electrons in the fit place.

  5. ECR ion source with electron gun

    Science.gov (United States)

    Xie, Z.Q.; Lyneis, C.M.

    1993-10-26

    An Advanced Electron Cyclotron Resonance ion source having an electron gun for introducing electrons into the plasma chamber of the ion source is described. The ion source has a injection enclosure and a plasma chamber tank. The plasma chamber is defined by a plurality of longitudinal magnets. The electron gun injects electrons axially into the plasma chamber such that ionization within the plasma chamber occurs in the presence of the additional electrons produced by the electron gun. The electron gun has a cathode for emitting electrons therefrom which is heated by current supplied from an AC power supply while bias potential is provided by a bias power supply. A concentric inner conductor and outer conductor carry heating current to a carbon chuck and carbon pusher which hold the cathode in place and also heat the cathode. In the Advanced Electron Cyclotron Resonance ion source, the electron gun replaces the conventional first stage used in prior electron cyclotron resonance ion generators. 5 figures.

  6. Silicene for Na-ion battery applications

    KAUST Repository

    Zhu, Jiajie

    2016-08-19

    Na-ion batteries are promising candidates to replace Li-ion batteries in large scale applications because of the advantages in natural abundance and cost of Na. Silicene has potential as the anode in Li-ion batteries but so far has not received attention with respect to Na-ion batteries. In this context, freestanding silicene, a graphene-silicene-graphene heterostructure, and a graphene-silicene superlattice are investigated for possible application in Na-ion batteries, using first-principles calculations. The calculated Na capacities of 954mAh/g for freestanding silicene and 730mAh/g for the graphenesilicene superlattice (10% biaxial tensile strain) are highly competitive and potentials of >0.3 V against the Na/Na potential exceed the corresponding value of graphite. In addition, the diffusion barriers are predicted to be <0.3 eV.

  7. Ion cyclotron emission by spontaneous emission

    Energy Technology Data Exchange (ETDEWEB)

    Da Costa, O. [Commission of the European Communities, Abingdon (United Kingdom). JET Joint Undertaking; Gresillon, D. [Ecole Polytechnique, 91 - Palaiseau (France). Lab. de Physique des Milieux Ionises

    1994-07-01

    The goal of the study is to examine whether the spontaneous emission can account for ICE (ion cyclotron emission) experimental results, or part of them. A straightforward approach to plasma emission is chosen, investigating the near equilibrium wave radiation by gyrating ions, and thus building from the majority and fast fusion ions the plasma fluctuations and emission on the fast magnetoacoustic or compressional Alfven wave mode in the IC frequency range. Similarities with the ICE experiments are shown: the emission temperature in the presence of fast ions (even in a very small amount), the strong fast ion emission increase with the harmonic, the fine double-line splitting of each peak, the linear but not proportional increase of the peak width with the harmonic. 3 refs., 2 figs.

  8. Logic gates based on ion transistors.

    Science.gov (United States)

    Tybrandt, Klas; Forchheimer, Robert; Berggren, Magnus

    2012-05-29

    Precise control over processing, transport and delivery of ionic and molecular signals is of great importance in numerous fields of life sciences. Integrated circuits based on ion transistors would be one approach to route and dispense complex chemical signal patterns to achieve such control. To date several types of ion transistors have been reported; however, only individual devices have so far been presented and most of them are not functional at physiological salt concentrations. Here we report integrated chemical logic gates based on ion bipolar junction transistors. Inverters and NAND gates of both npn type and complementary type are demonstrated. We find that complementary ion gates have higher gain and lower power consumption, as compared with the single transistor-type gates, which imitates the advantages of complementary logics found in conventional electronics. Ion inverters and NAND gates lay the groundwork for further development of solid-state chemical delivery circuits.

  9. Photoionisation of ions with synchrotron radiation: from ions in space to atoms in cages

    Energy Technology Data Exchange (ETDEWEB)

    Schippers, Stefan; Kilcoyne, A. L. David; Phaneuf, Ronald A.; Müller, Alfred

    2015-11-11

    Here, we introduce the photon-ion merged-beams technique for the photoionisation of mass/charge selected ionised atoms, molecules and clusters by x-rays from synchrotron radiation sources. Examples for photoionisation of atomic ions are discussed by going from outer shell ionisation of simple few electron systems to inner shell ionisation of complex many electron ions. Fundamental ionisation mechanisms are elucidated and the importance of the results for applications in astrophysics and plasma physics is pointed out. Finally, the unique capabilities of the photon-ion merged-beams technique for the study of photoabsorption by nanoparticles are demonstrated by the example of endohedral fullerene ions.

  10. GANIL Workshop on Ion Sources; Journees Sources d'Ions

    Energy Technology Data Exchange (ETDEWEB)

    Leroy, Renan [Grand Accelerateur National d' Ions Lourds (GANIL), 14 - Caen (France)

    1999-07-01

    The proceedings of the GANIL Workshop on Ion Sources held at GANIL - Caen on 18-19 March 1999 contains 13 papers aiming at improving the old source operation and developing new types of sources for nuclear research and studies of ion physics. A number of reports are devoted to applications like surface treatment, ion implantation or fusion injection. The 1+{yields}n+ transformation, charged particle transport in ECR sources, addition of cesium and xenon in negative ion sources and other basic issues in ion sources are also addressed.

  11. Energetic ion leakage from foreshock transient cores

    Science.gov (United States)

    Liu, Terry Z.; Angelopoulos, Vassilis; Hietala, Heli

    2017-07-01

    Earth's foreshock is filled with backstreaming particles that can interact with the ambient solar wind and its discontinuities to form foreshock transients. Many foreshock transients have a core with low dynamic pressure that can significantly perturb the bow shock and the magnetosphere-ionosphere system. Foreshock transients have also been recently recognized as sites of particle acceleration, which may be important for seeding the parent shock with energetic particles. A relevant step of this seeding would be energetic ion leakage into the surrounding foreshock environment. On the other hand, such leakage would also suppress the energetic particle flux contrast across foreshock transients' boundaries masking their perceived contribution to ion energization. To further examine this hypothesis of ion leakage, we report on multipoint case studies of three foreshock transient events selected from a large database. The cases were selected to exemplify, in increasing complexity, the nature and consequences of energetic ion leakage. Ion energy dispersion, observed upstream and/or downstream of the foreshock transients, is explained with a simple, ballistic model of ions leaking from the foreshock transients. Larger energies are required for leaked ions to reach the spacecraft as the distance between the transient and spacecraft increases. Our model, which explains well the observed ion energy dispersion and velocity distributions, can also be used to reveal the shape of the foreshock transients in three dimensions. Our results suggest that ion leakage from foreshock transient cores needs to be accounted for both in statistical studies and in global models of ion acceleration under quasi-parallel foreshock conditions.

  12. Pengaruh Ion Na+, Ion Hg2+ dan Ion Cr3+ Terhadap Kinerja Sensor Potensiometri Ion Timbal (II Tipe Kawat Terlapis Berbasis Pirofilit

    Directory of Open Access Journals (Sweden)

    Qanitah Fardiyah

    2016-08-01

    Full Text Available Generally ionophores  (active materials in a potentiometric is derived from organic compounds. In this research used ionophores derived from ainorganic compounds that pyrophyllite. Potentiometric sensors lead (II ions based on pyrophyllite as ionofor has been developed. The electrode had  polyvinilchloride (PVC as polymer matrix and dioctylpthalate (DOP as plasticizer. It showed a good Nernstian slope of 29.33 mV/decade, a lead linear range concentration between 10-1- 10-5 M, and detection limit of 8.054 x10-6 M  (equal with 1.669 ppm of lead. By using the electrode, the objectives of this research were to investigate the effect of interfering ions  Na+, ion Hg2+ and ion Cr3+ to the performance of the potentiometric sensors lead(II ion based pyrophyllite coated wire type. The selective coefficients (kij were determined using the mix solution methode  at  10-3 M of interfering ion. The result showed that the potentiometric sensors lead(II ions based  on pyrophyllite coated wire type could be used optimally at  pH 5. The potentiometric sensors lead(II ion based pyrophyllite coated wire type showed a good selectivity for interfering ions (Na+, Hg2+, dan Cr3+ and showed no interference to the performance of the potentiometric sensors lead (II ion based pyrophyllite coated wire type with selectivity order of Pb2+> Hg2+> Cr3+> Na+. DOI :http://dx.doi.org/10.15408/jkv.v0i0.3144

  13. Ion Acceleration by Double Layers with Multi-Component Ion Species

    Science.gov (United States)

    Good, Timothy; Aguirre, Evan; Scime, Earl; West Virginia University Team

    2017-10-01

    Current-free double layers (CFDL) models have been proposed to explain observations of magnetic field-aligned ion acceleration in plasmas expanding into divergent magnetic field regions. More recently, experimental studies of the Bohm sheath criterion in multiple ion species plasma reveal an equilibration of Bohm speeds at the sheath-presheath boundary for a grounded plate in a multipole-confined filament discharge. We aim to test this ion velocity effect for CFDL acceleration. We report high resolution ion velocity distribution function (IVDF) measurements using laser induced fluorescence downstream of a CFDL in a helicon plasma. Combinations of argon-helium, argon-krypton, and argon-xenon gases are ionized and measurements of argon or xenon IVDFs are investigated to determine whether ion acceleration is enhanced (or diminished) by the presence of lighter (or heavier) ions in the mix. We find that the predominant effect is a reduction of ion acceleration consistent with increased drag arising from increased gas pressure under all conditions, including constant total gas pressure, equal plasma densities of different ions, and very different plasma densities of different ions. These results suggest that the physics responsible for acceleration of multiple ion species in simple sheaths is not responsible for the ion acceleration observed in these expanding plasmas. Department of Physics, Gettysburg College.

  14. Physical mechanisms leading to high currents of highly charged ions in laser-driven ion sources

    Energy Technology Data Exchange (ETDEWEB)

    Haseroth, Helmut [European Organization for Nuclear Research, Geneva (Switzerland); Hora, Heinrich [New South Wales Univ., Kensington, NSW (Australia)]|[Regensburg Inst. of Tech. (Germany). Anwenderzentrum

    1996-12-31

    Heavy ion sources for the big accelerators, for example, the LHC, require considerably more ions per pulse during a short time than the best developed classical ion source, the electron cyclotron resonance (ECR) provides; thus an alternative ion source is needed. This can be expected from laser-produced plasmas, where dramatically new types of ion generation have been observed. Experiments with rather modest lasers have confirmed operation with one million pulses of 1 Hz, and 10{sup 11} C{sup 4+} ions per pulse reached 2 GeV/u in the Dubna synchrotron. We review here the complexities of laser-plasma interactions to underline the unique and extraordinary possibilities that the laser ion source offers. The complexities are elaborated with respect to keV and MeV ion generation, nonlinear (ponderomotive) forces, self-focusing, resonances and ``hot`` electrons, parametric instabilities, double-layer effects, and the few ps stochastic pulsation (stuttering). Recent experiments with the laser ion source have been analyzed to distinguish between the ps and ns interaction, and it was discovered that one mechanism of highly charged ion generation is the electron impact ionization (EII) mechanism, similar to the ECR, but with so much higher plasma densities that the required very large number of ions per pulse are produced. (author).

  15. Neutralized ion beam modification of cellulose membranes for study of ion charge effect on ion-beam-induced DNA transfer

    Energy Technology Data Exchange (ETDEWEB)

    Prakrajang, K., E-mail: k.prakrajang@gmail.com [Plasma and Beam Physics Research Facility, Department of Physics and Materials Science, Faculty of Science, Chiang Mai University, Chiang Mai 50200 (Thailand); Sangwijit, K.; Anuntalabhochai, S. [Molecular Biology Laboratory, Department of Biology, Faculty of Science, Chiang Mai University, Chiang Mai 50200 (Thailand); Wanichapichart, P. [Membrane Science and Technology Research Center, Department of Physics, Faculty of Science, Prince of Songkla University, Hat Yai, Songkla 90110 (Thailand); Thailand Center of Excellence in Physics, Commission on Higher Education, 328 Si Ayutthaya Road, Bangkok 10400 (Thailand); Yu, L.D., E-mail: yuld@fnrf.science.cmu.ac.th [Plasma and Beam Physics Research Facility, Department of Physics and Materials Science, Faculty of Science, Chiang Mai University, Chiang Mai 50200 (Thailand); Thailand Center of Excellence in Physics, Commission on Higher Education, 328 Si Ayutthaya Road, Bangkok 10400 (Thailand)

    2012-02-01

    Low-energy ion beam biotechnology (IBBT) has recently been rapidly developed worldwide. Ion-beam-induced DNA transfer is one of the important applications of IBBT. However, mechanisms involved in this application are not yet well understood. In this study plasma-neutralized ion beam was applied to investigate ion charge effect on induction of DNA transfer. Argon ion beam at 7.5 keV was neutralized by RF-driven plasma in the beam path and then bombarded cellulose membranes which were used as the mimetic plant cell envelope. Electrical properties such as impedance and capacitance of the membranes were measured after the bombardment. An in vitro experiment on plasmid DNA transfer through the cellulose membrane was followed up. The results showed that the ion charge input played an important role in the impedance and capacitance changes which would affect DNA transfer. Generally speaking, neutral particle beam bombardment of biologic cells was more effective in inducing DNA transfer than charged ion beam bombardment.

  16. A high energy, heavy ion microprobe for ion beam research on the tandem accelerator at ANSTO

    Energy Technology Data Exchange (ETDEWEB)

    Cohen, D.D.; Siegele, R.; Dytlewski, N.

    1996-04-01

    A comprehensive review is given on the production and use of heavy ion beams with spot sizes of a few {mu}m. The development of a high energy, heavy ion microprobe at ANSTO and its possible applications are discussed. The microprobe is designed to focus a wide range of ion beam types, from light ions such as protons up to ions as heavy as iodine. Details of the ion beam optics, optical calculations and a description of the proposed microbeam design are given. The unique combination of high energy, heavy ions and improved detection systems will provide high sensitivity elemental composition and depth profiling information, allowing surface topography and 3D surface reconstruction to be performed on a broad range of materials. 86 refs., 5 tabs., 15 figs.

  17. An ion gun and detector system for ion drift surface studies on toroidal devices

    Science.gov (United States)

    Sasser, G. E.; Knowlton, S. F.; Gandy, R. F.; Lin, H.; Thomas, E. E.; Owens, M. A.

    1995-01-01

    An ion gun and detector system have been designed and tested to study energetic ion trajectories and single-particle confinement in the vacuum field and low-density plasma of the Compact Auburn Torsatron (CAT). Thermionic Li+ and Mg+ sources are used. The gun positioning is capable of two degrees of freedom, allowing selection of the pitch angle and initial flux surface. The injection energy of the ions is variable from 5 to 100 eV, allowing investigation of the orbits of particles with large Larmor radii. The ion currents of typical magnitude I=10 nA are detected with a movable paddle probe making use of a boxcar-averaging technique. The detected ion trajectories are compared with the predicted trajectories from a guiding center code that makes use of a detailed model of the CAT magnetic configuration. The ion gun and detector system will be used to study the effect of magnetic islands on energetic ion trajectories.

  18. Monitoring Ion Activities In and Around Cells Using Ion-Selective Liquid-Membrane Microelectrodes

    Directory of Open Access Journals (Sweden)

    Mark D. Parker

    2013-01-01

    Full Text Available Determining the effective concentration (i.e., activity of ions in and around living cells is important to our understanding of the contribution of those ions to cellular function. Moreover, monitoring changes in ion activities in and around cells is informative about the actions of the transporters and/or channels operating in the cell membrane. The activity of an ion can be measured using a glass microelectrode that includes in its tip a liquid-membrane doped with an ion-selective ionophore. Because these electrodes can be fabricated with tip diameters that are less than 1 μm, they can be used to impale single cells in order to monitor the activities of intracellular ions. This review summarizes the history, theory, and practice of ion-selective microelectrode use and brings together a number of classic and recent examples of their usefulness in the realm of physiological study.

  19. Preliminary Tests of a Paul ion Trap as an Ion Source

    Science.gov (United States)

    Sadat Kiai, S. M.; Zirak, A. R.; Elahi, M.; Adlparvar, S.; Mortazavi, B. N.; Safarien, A.; Farhangi, S.; Sheibani, S.; Alhooie, S.; Khalaj, M. M. A.; Dabirzadeh, A. A.; Ruzbehani, M.; Zahedi, F.

    2010-10-01

    The paper reports on the design and construction of a Paul ion trap as an ion source by using an impact electron ionization technique. Ions are produced in the trap and confined for the specific time which is then extracted and detected by a Faraday cup. Especial electronic configurations are employed between the end caps, ring electrodes, electron gun and a negative voltage for the detector. This configuration allows a constant low level of pure ion source between the pulsed confined ion sources. The present experimental results are based on the production and confinement of Argon ions with good stability and repeatability, but in principle, the technique can be used for various Argon like ions.

  20. Importance of diffuse metal ion binding to RNA.

    Science.gov (United States)

    Tan, Zhi-Jie; Chen, Shi-Jie

    2011-01-01

    RNAs are highly charged polyanionic molecules. RNA structure and function are strongly correlated with the ionic condition of the solution. The primary focus of this article is on the role of diffusive ions in RNA folding. Due to the long-range nature of electrostatic interactions, the diffuse ions can contribute significantly to RNA structural stability and folding kinetics. We present an overview of the experimental findings as well as the theoretical developments on the diffuse ion effects in RNA folding. This review places heavy emphasis on the effect of magnesium ions. Magnesium ions play a highly efficient role in stabilizing RNA tertiary structures and promoting tertiary structural folding. The highly efficient role goes beyond the mean-field effect such as the ionic strength. In addition to the effects of specific ion binding and ion dehydration, ion-ion correlation for the diffuse ions can contribute to the efficient role of the multivalent ions such as the magnesium ions in RNA folding.