WorldWideScience

Sample records for tensor magnetic resonance

  1. White Matter Integrity in Asperger Syndrome: A Preliminary Diffusion Tensor Magnetic Resonance Imaging Study in Adults

    NARCIS (Netherlands)

    Bloemen, Oswald J. N.; Deeley, Quinton; Sundram, Fred; Daly, Eileen M.; Barker, Gareth J.; Jones, Derek K.; van Amelsvoort, Therese A. M. J.; Schmitz, Nicole; Robertson, Dene; Murphy, Kieran C.; Murphy, Declan G. M.

    2010-01-01

    Background: Autistic Spectrum Disorder (ASD), including Asperger syndrome and autism, is a highly genetic neurodevelopmental disorder. There is a consensus that ASD has a biological basis, and it has been proposed that it is a "connectivity" disorder. Diffusion Tensor Magnetic Resonance Imaging

  2. Nonlocal weakly relativistic permittivity tensor of magnetized plasma near electron cyclotron resonances

    Science.gov (United States)

    Sakharov, A. S.

    2017-11-01

    Compact expressions are derived for the nonlocal permittivity tensor of weakly relativistic plasma in a 2D nonuniform magnetic field near the resonances at the second harmonic of the electron cyclotron frequency for an extraordinary wave and at the first harmonic for an ordinary wave. It is shown that the wave equation with allowance for the obtained thermal correction to the permittivity tensor in the form of a differential operator in transverse (with respect to the external magnetic field) coordinates possesses an integral in the form of the energy conservation law.

  3. MAGNETIC RESONANCE WATER SELF-DIFFUSION TENSOR ENCODING OPTIMIZATION METHODS FOR FULL BRAIN ACQUISITION

    Directory of Open Access Journals (Sweden)

    Khader M Hasan

    2011-05-01

    Full Text Available Water diffusion tensor magnetic resonance imaging (DT-MRI is a non-invasive and sensitive modality that is becoming increasingly popular in diagnostic radiology. DT-MRI provides in vivo directional information about the organization and microdynamics of deep brain tissue that is not available by other MRI relaxationbased methods. The DT-MRI experiment involves a host of imaging and diffusion parameters that influence the efficiency (signal-to-noise ratio per unit time, accuracy, and specificity of the information sought. These parameters may include typical imaging parameters such as TE, TR, slice thickness, sampling rate, etc. The DTI relevant parameter space includes pulse duration, separation, direction, number of directions (Ne, order, sign and strength of the diffusion encoding gradient pulses. The goal of this work is to present and compare different tensor encoding strategies used to obtain the DT-MRI information for the whole brain. In this paper an evaluation of tensor encoding advantage is presented using a multi-dimensional non-parametric Bootstrap resampling method. This work also explores the relationship between different tensor encoding schemes using the analytical encoding approach. This work shows that the minimum energy optimization approach can produce uniformly distributed tensor encoding that are comparable to the icosahedral sets. The minimum condition encoding sets are not uniformly distributed and are shown to be suboptimal and related to a commonly used heuristic tensor encoding set. This work shows that the icosahedral set is the only uniformly distributed set with Ne = 6. At equal imaging time, the Bootstrap experiments show that optimal tensor encoding sets can have 6 < Ne < 24.

  4. Visualizing functional pathways in the human brain using correlation tensors and magnetic resonance imaging.

    Science.gov (United States)

    Ding, Zhaohua; Xu, Ran; Bailey, Stephen K; Wu, Tung-Lin; Morgan, Victoria L; Cutting, Laurie E; Anderson, Adam W; Gore, John C

    2016-01-01

    Functional magnetic resonance imaging usually detects changes in blood oxygenation level dependent (BOLD) signals from T2*-sensitive acquisitions, and is most effective in detecting activity in brain cortex which is irrigated by rich vasculature to meet high metabolic demands. We recently demonstrated that MRI signals from T2*-sensitive acquisitions in a resting state exhibit structure-specific temporal correlations along white matter tracts. In this report we validate our preliminary findings and introduce spatio-temporal functional correlation tensors to characterize the directional preferences of temporal correlations in MRI signals acquired at rest. The results bear a remarkable similarity to data obtained by diffusion tensor imaging but without any diffusion-encoding gradients. Just as in gray matter, temporal correlations in resting state signals may reflect intrinsic synchronizations of neural activity in white matter. Here we demonstrate that functional correlation tensors are able to visualize long range white matter tracts as well as short range sub-cortical fibers imaged at rest, and that evoked functional activities alter these structures and enhance the visualization of relevant neural circuitry. Furthermore, we explore the biophysical mechanisms underlying these phenomena by comparing pulse sequences, which suggest that white matter signal variations are consistent with hemodynamic (BOLD) changes associated with neural activity. These results suggest new ways to evaluate MRI signal changes within white matter. Copyright © 2015 Elsevier Inc. All rights reserved.

  5. Denoising human cardiac diffusion tensor magnetic resonance images using sparse representation combined with segmentation

    Science.gov (United States)

    Bao, L. J.; Zhu, Y. M.; Liu, W. Y.; Croisille, P.; Pu, Z. B.; Robini, M.; Magnin, I. E.

    2009-03-01

    Cardiac diffusion tensor magnetic resonance imaging (DT-MRI) is noise sensitive, and the noise can induce numerous systematic errors in subsequent parameter calculations. This paper proposes a sparse representation-based method for denoising cardiac DT-MRI images. The method first generates a dictionary of multiple bases according to the features of the observed image. A segmentation algorithm based on nonstationary degree detector is then introduced to make the selection of atoms in the dictionary adapted to the image's features. The denoising is achieved by gradually approximating the underlying image using the atoms selected from the generated dictionary. The results on both simulated image and real cardiac DT-MRI images from ex vivo human hearts show that the proposed denoising method performs better than conventional denoising techniques by preserving image contrast and fine structures.

  6. /sup 31/P nuclear magnetic resonance chemical shielding tensors of L-0-serine phosphate and 3'-cytidine monophosphate

    Energy Technology Data Exchange (ETDEWEB)

    Kohler, S.J.; Klein, M.P.

    1977-12-07

    /sup 31/P nuclear magnetic resonance chemical shielding tensors have been measured from single crystals of L-O-serine phosphate and 3'-cytidine monophosphate. The principal elements of the shielding tensors are -48, -2, and 51 ppM for serine phosphate and -68, -13, and 64 ppM for 3'-cytidine monophosphate, relative to 85% H/sub 3/PO/sub 4/. In both cases four orientations of the shielding tensor on the molecule are possible; in both instances one orientation correlates well with the P--O bond directions. This orientation of the shielding tensor places the most downfield component of the tensor in the plane containing the two longest P--O bonds and the most upfield component of the shielding tensor in the plane containing the two shortest P--O bonds. A similar orientation was reported for the /sup 31/P shielding tensor of phosphorylethanolamine and a comparison is made between the three molecules.

  7. Interrogating the origin and behavior of magnetic resonance diffusion tensor scalar parameters in the myocardium

    Science.gov (United States)

    Abdullah, Osama Mahmoud

    Myocardial microstructure plays an important role in sustaining the orchestrated beating motion of the heart. Several microstructural components, including myocytes and auxiliary cells, extracellular space, and blood vessels provide the infrastructure for normal heart function, including excitation propagation, myocyte contraction, delivery of oxygen and nutrients, and removing byproduct wastes. Cardiac diseases cause deleterious changes to some or all of these microstructural components in the detrimental process of cardiac remodeling. Since heart failure is among the leading causes of death in the world, new and novel tools to noninvasively characterize heart microstructure are needed for monitoring and staging of cardiac disease. In this regards, diffusion magnetic resonance imaging (MRI) provides a promising framework to probe and quantify tissue microstructure without the need for exogenous contrast agent. As diffusion in 3-dimensional space is characterized by the diffusion tensor, MR diffusion tensor imaging (DTI) is being used to noninvasively measure anisotropic diffusion, and thus the magnitude and spatial orientation of microstructural organization of tissues, including the heart. However, even though in vivo cardiac DTI has become more clinically available, to date the origin and behavior of different microstructural components on the measured DTI signal remain to be explicitly specified. The presented studies in this work demonstrate that DTI can be used as a noninvasive and contrast-free imaging modality to characterize myocyte size and density, extracellular collagen content, and the directional magnitude of blood flow. The identified applications are expected to provide metrics to enable physicians to detect, quantify, and stage different microstructural components during progression of cardiac disease.

  8. Tractography of the spider monkey (Ateles geoffroyi corpus callosum using diffusion tensor magnetic resonance imaging.

    Directory of Open Access Journals (Sweden)

    Diana Platas-Neri

    Full Text Available The objective of this research was to describe the organization, connectivity and microstructure of the corpus callosum of the spider monkey (Ateles geoffroyi. Non-invasive magnetic resonance imaging and diffusion-tensor imaging were obtained from three subjects using a 3T Philips scanner. We hypothesized that the arrangement of fibers in spider monkeys would be similar to that observed in other non-human primates. A repeated measure (n = 3 of fractional anisotropy values was obtained of each subject and for each callosal subdivision. Measurements of the diffusion properties of corpus callosum fibers exhibited a similar pattern to those reported in the literature for humans and chimpanzees. No statistical difference was reached when comparing this parameter between the different CC regions (p = 0.066. The highest fractional anisotropy values corresponded to regions projecting from the corpus callosum to the posterior cortical association areas, premotor and supplementary motor cortices. The lowest fractional anisotropy corresponded to projections to motor and sensory cortical areas. Analyses indicated that approximately 57% of the fibers projects to the frontal cortex and 43% to the post-central cortex. While this study had a small sample size, the results provided important information concerning the organization of the corpus callosum in spider monkeys.

  9. White matter integrity in Asperger syndrome: a preliminary diffusion tensor magnetic resonance imaging study in adults.

    Science.gov (United States)

    Bloemen, Oswald J N; Deeley, Quinton; Sundram, Fred; Daly, Eileen M; Barker, Gareth J; Jones, Derek K; van Amelsvoort, Therese A M J; Schmitz, Nicole; Robertson, Dene; Murphy, Kieran C; Murphy, Declan G M

    2010-10-01

    Autistic Spectrum Disorder (ASD), including Asperger syndrome and autism, is a highly genetic neurodevelopmental disorder. There is a consensus that ASD has a biological basis, and it has been proposed that it is a "connectivity" disorder. Diffusion Tensor Magnetic Resonance Imaging (DT-MRI) allows measurement of the microstructural integrity of white matter (a proxy measure of "connectivity"). However, nobody has investigated the microstructural integrity of whole brain white matter in people with Asperger syndrome. We measured the fractional anisotropy (FA), mean diffusivity (MD) and radial diffusivity (RD) of white matter, using DT-MRI, in 13 adults with Asperger syndrome and 13 controls. The groups did not differ significantly in overall intelligence and age. FA, MD and RD were assessed using whole brain voxel-based techniques. Adults with Asperger syndrome had a significantly lower FA than controls in 13 clusters. These were largely bilateral and included white matter in the internal capsule, frontal, temporal, parietal and occipital lobes, cingulum and corpus callosum. Adults with Asperger syndrome have widespread significant differences from controls in white matter microstructural integrity.

  10. Human cervical spinal cord funiculi: investigation with magnetic resonance diffusion tensor imaging.

    Science.gov (United States)

    Onu, Mihaela; Gervai, Patricia; Cohen-Adad, Julien; Lawrence, Jane; Kornelsen, Jennifer; Tomanek, Boguslaw; Sboto-Frankenstein, Uta Nicola

    2010-04-01

    To use spinal cord diffusion tensor imaging (DTI) for investigating human cervical funiculi, acquire axial diffusion magnetic resonance imaging (MRI) data with an in-plane resolution sufficient to delineate subquadrants within the spinal cord, obtain corresponding DTI metrics, and assess potential regional differences. Healthy volunteers were studied with a 3 T Siemens Trio MRI scanner. DTI data were acquired using a single-shot spin echo EPI sequence. The spatial resolution allowed for the delineation of regions of interest (ROIs) in the ventral, dorsal, and lateral spinal cord funiculi. ROI-based and tractography-based analyses were performed. Significant fractional anisotropy (FA) differences were found between ROIs in the dorsal and ventral funiculi (P = 0.0001), dorsal and lateral funiculi (P = 0.015), and lateral and ventral funiculi (P = 0.0002). Transverse diffusivity was significantly different between ROIs in the ventral and dorsal funiculi (P = 0.003) and the ventral and lateral funiculi (P = 0.004). Tractography-based quantifications revealed DTI parameter regional differences that were generally consistent with the ROI-based analysis. Original contributions are: 1) the use of a tractography-based method to quantify DTI metrics in the human cervical spinal cord, and 2) reported DTI values in various funiculi at 3 T. (c) 2010 Wiley-Liss, Inc.

  11. Diffusion tensor magnetic resonance imaging driven growth modeling for radiotherapy target definition in glioblastoma.

    Science.gov (United States)

    Jensen, Morten B; Guldberg, Trine L; Harbøll, Anja; Lukacova, Slávka; Kallehauge, Jesper F

    2017-11-01

    The clinical target volume (CTV) in radiotherapy is routinely based on gadolinium contrast enhanced T1 weighted (T1w + Gd) and T2 weighted fluid attenuated inversion recovery (T2w FLAIR) magnetic resonance imaging (MRI) sequences which have been shown to over- or underestimate the microscopic tumor cell spread. Gliomas favor spread along the white matter fiber tracts. Tumor growth models incorporating the MRI diffusion tensors (DTI) allow to account more consistently for the glioma growth. The aim of the study was to investigate the potential of a DTI driven growth model to improve target definition in glioblastoma (GBM). Eleven GBM patients were scanned using T1w, T2w FLAIR, T1w + Gd and DTI. The brain was segmented into white matter, gray matter and cerebrospinal fluid. The Fisher-Kolmogorov growth model was used assuming uniform proliferation and a difference in white and gray matter diffusion of a ratio of 10. The tensor directionality was tested using an anisotropy weighting parameter set to zero (γ0) and twenty (γ20). The volumetric comparison was performed using Hausdorff distance, Dice similarity coefficient (DSC) and surface area. The median of the standard CTV (CTVstandard) was 180 cm3. The median surface area of CTVstandard was 211 cm2. The median surface area of respective CTVγ0 and CTVγ20 significantly increased to 338 and 376 cm2, respectively. The Hausdorff distance was greater than zero and significantly increased for both CTVγ0 and CTVγ20 with respective median of 18.7 and 25.2 mm. The DSC for both CTVγ0 and CTVγ20 were significantly below one with respective median of 0.74 and 0.72, which means that 74 and 72% of CTVstandard were included in CTVγ0 and CTVγ20, respectively. DTI driven growth models result in CTVs with a significantly increased surface area, a significantly increased Hausdorff distance and decreased overlap between the standard and model derived volume.

  12. Combination of diffusion tensor and functional magnetic resonance imaging during recovery from the vegetative state

    Directory of Open Access Journals (Sweden)

    Fernández-Espejo Davinia

    2010-09-01

    Full Text Available Abstract Background The rate of recovery from the vegetative state (VS is low. Currently, little is known of the mechanisms and cerebral changes that accompany those relatively rare cases of good recovery. Here, we combined functional magnetic resonance imaging (fMRI and diffusion tensor imaging (DTI to study the evolution of one VS patient at one month post-ictus and again twelve months later when he had recovered consciousness. Methods fMRI was used to investigate cortical responses to passive language stimulation as well as task-induced deactivations related to the default-mode network. DTI was used to assess the integrity of the global white matter and the arcuate fasciculus. We also performed a neuropsychological assessment at the time of the second MRI examination in order to characterize the profile of cognitive deficits. Results fMRI analysis revealed anatomically appropriate activation to speech in both the first and the second scans but a reduced pattern of task-induced deactivations in the first scan. In the second scan, following the recovery of consciousness, this pattern became more similar to that classically described for the default-mode network. DTI analysis revealed relative preservation of the arcuate fasciculus and of the global normal-appearing white matter at both time points. The neuropsychological assessment revealed recovery of receptive linguistic functioning by 12-months post-ictus. Conclusions These results suggest that the combination of different structural and functional imaging modalities may provide a powerful means for assessing the mechanisms involved in the recovery from the VS.

  13. Anatomical Characterization of Human Fetal Brain Development with Diffusion Tensor Magnetic Resonance Imaging

    Science.gov (United States)

    Huang, Hao; Xue, Rong; Zhang, Jiangyang; Ren, Tianbo; Richards, Linda J.; Yarowsky, Paul; Miller, Michael I.; Mori, Susumu

    2009-01-01

    The human brain is extraordinarily complex, and yet its origin is a simple tubular structure. Characterizing its anatomy at different stages of human fetal brain development not only aids in understanding this highly ordered process but also provides clues to detecting abnormalities caused by genetic or environmental factors. During the second trimester of human fetal development, neural structures in the brain undergo significant morphological changes. Diffusion tensor imaging (DTI), a novel method of magnetic resonance imaging, is capable of delineating anatomical components with high contrast and revealing structures at the microscopic level. In this study, high-resolution and high-signal-to-noise-ratio DTI data of fixed tissues of second-trimester human fetal brains were acquired and analyzed. DTI color maps and tractography revealed that important white matter tracts, such as the corpus callosum and uncinate and inferior longitudinal fasciculi, become apparent during this period. Three-dimensional reconstruction shows that major brain fissures appear while most of the cerebral surface remains smooth until the end of the second trimester. A dominant radial organization was identified at 15 gestational weeks, followed by both laminar and radial architectures in the cerebral wall throughout the remainder of the second trimester. Volumetric measurements of different structures indicate that the volumes of basal ganglia and ganglionic eminence increase along with that of the whole brain, while the ventricle size decreases in the later second trimester. The developing fetal brain DTI database presented can be used for education, as an anatomical research reference, and for data registration. PMID:19339620

  14. Late-Onset Neurodegeneration with Brain Iron Accumulation with Diffusion Tensor Magnetic Resonance Imaging

    Directory of Open Access Journals (Sweden)

    Syed Omar Shah

    2012-12-01

    Full Text Available Introduction: Neuroferritinopathy is an autosomal dominant neurodegenerative disorder that includes a movement disorder, cognitive decline, and characteristic findings on brain magnetic resonance imaging (MRI due to abnormal iron deposition. Here, we present a late-onset case, along with diffusion tensor imaging (DTI. Case Presentation: We report the case of a 74-year-old Caucasian female with no significant past medical history who presented for evaluation of orofacial dyskinesia, suspected to be edentulous dyskinesia given her history of ill-fitting dentures. She had also developed slowly progressive dysarthria, dysphagia, visual hallucinations as well as stereotypic movements of her hands and feet. Results: The eye-of-the-tiger sign was demonstrated on T2 MRI. Increased fractional anisotropy and T2 hypointensity were observed in the periphery of the globus pallidus, putamen, substantia nigra, and dentate nucleus. T2 hyperintensity was present in the medial dentate nucleus and central globus pallidus. Discussion: The pallidal MRI findings were more typical of pantothenate kinase-associated neurodegeneration (PKAN, but given additional dentate and putamenal involvement, lack of retinopathy, and advanced age of onset, PKAN was less likely. Although the patient’s ferritin levels were within low normal range, her clinical and imaging features led to a diagnosis of neuroferritinopathy. Conclusion: Neurodegeneration with brain iron accumulation (NBIA is a rare cause of orofacial dyskinesia. DTI MRI can confirm abnormal iron deposition. The location of abnormal iron deposits helps in differentiating NBIA subtypes. Degeneration of the dentate and globus pallidus may occur via an analogous process given their similar T2 and DTI MRI appearance.

  15. Diffusion tensor and volumetric magnetic resonance imaging findings in the brains of professional musicians.

    Science.gov (United States)

    Acer, Niyazi; Bastepe-Gray, Serap; Sagiroglu, Ayse; Gumus, Kazim Z; Degirmencioglu, Levent; Zararsiz, Gokmen; Ozic, Muhammet Usame

    2018-03-01

    Professional musicians represent an ideal model to study the training-induced brain plasticity. The current study aimed to investigate the brain volume and diffusion characteristics of musicians using structural magnetic resonance and diffusion tensor imaging (DTI). The combined use of volumetric and diffusion methods in studying musician brain has not been done in literature. Our study group consisted of seven male musicians playing an instrument and seven age- and gender-matched non-musicians. We evaluated the volumes of gray matter (GM), white matter (WM), and cerebrospinal fluid (CSF) and calculated total intracranial volume (TIV) and measured the fractional anisotropy (FA) of pre-selected WM bundles: corpus callosum (CC), corticospinal tract (CST), superior longitudinal fasciculus (SLF), forceps major (ForMaj), forceps minor (ForMin), and arcuate fasciculus (AF). The mean WM/TIV volume in musicians was higher compared to non-musicians. The mean FA was lower in CC, SLF, ForMaj, ForMin, and right AF but higher in right CST in the musicians. The mean value of the total number of fibers was larger in the CST, SLF, left AF, and ForMaj in the musicians. The observed differences were not statistically significant between the groups (p>0.05). However, increased GM volume was found in the musicians compared to the non-musicians in the right and left cerebellum and supramarginal and angular gyrus, left superior and inferior parietal lobule and as well as left middle temporal gyrus. Our findings suggest differing brain structure in musicians and the confirmation of the results on a larger population. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Diffusion tensor magnetic resonance imaging of trigeminal nerves in relapsing herpetic keratouveitis.

    Directory of Open Access Journals (Sweden)

    Antoine Rousseau

    Full Text Available Corneal hypoesthesia is the landmark of HSV and VZV keratitis and can lead to neurotrophic keratitis. Diffusion tensor imaging (DTI is a new magnetic resonance imaging (MRI derived technique, which offers possibilities to study axonal architecture. We aimed at assessing the potential impact of recurrent HSV or VZV-related keratitis on the axonal architecture of trigeminal nerves using DTI.Prospective non-interventional study.Twelve patients and 24 controls.DTI using MRI of the trigeminal fibers and corneal esthesiometry using the Cochet-Bonnet esthesiometer were acquired for patients affected by unilateral and recurrent HSV or VZV-related keratitis (3 months after the last corneal inflammatory event, and control subjects with no history of ocular or neuronal disease affecting the trigeminal pathways.Fractional anisotropy (FA and apparent diffusion coefficient (ADC were compared between the 2 eyes of both patients and controls, and correlated with corneal esthesiometry.FA was lower in the trigeminal fibers ipsilateral to the affected eye compared to the non-affected side (0.39±0.02 versus 0.46±0.04, P=0.03. This difference was more important than the intra-individual variability observed in controls. Concomitantly, the asymmetry in ADC results was significantly correlated with the loss of corneal sensitivity in the affected eye.Corneal hypoesthesia related to HSV and VZV keratitis is associated with persistent modifications in the architecture and functionality of the trigeminal fibers. These results add further explanation to the pathogenesis of HSV and VZV-induced neurotrophic keratitis, which may occur despite an apparent quiescence of the disease.

  17. Combination of diffusion tensor and functional magnetic resonance imaging during recovery from the vegetative state

    Science.gov (United States)

    2010-01-01

    Background The rate of recovery from the vegetative state (VS) is low. Currently, little is known of the mechanisms and cerebral changes that accompany those relatively rare cases of good recovery. Here, we combined functional magnetic resonance imaging (fMRI) and diffusion tensor imaging (DTI) to study the evolution of one VS patient at one month post-ictus and again twelve months later when he had recovered consciousness. Methods fMRI was used to investigate cortical responses to passive language stimulation as well as task-induced deactivations related to the default-mode network. DTI was used to assess the integrity of the global white matter and the arcuate fasciculus. We also performed a neuropsychological assessment at the time of the second MRI examination in order to characterize the profile of cognitive deficits. Results fMRI analysis revealed anatomically appropriate activation to speech in both the first and the second scans but a reduced pattern of task-induced deactivations in the first scan. In the second scan, following the recovery of consciousness, this pattern became more similar to that classically described for the default-mode network. DTI analysis revealed relative preservation of the arcuate fasciculus and of the global normal-appearing white matter at both time points. The neuropsychological assessment revealed recovery of receptive linguistic functioning by 12-months post-ictus. Conclusions These results suggest that the combination of different structural and functional imaging modalities may provide a powerful means for assessing the mechanisms involved in the recovery from the VS. PMID:20815871

  18. Examination of cognitive fatigue in multiple sclerosis using functional magnetic resonance imaging and diffusion tensor imaging

    National Research Council Canada - National Science Library

    Genova, Helen M; Rajagopalan, Venkateswaran; Deluca, John; Das, Abhijit; Binder, Allison; Arjunan, Aparna; Chiaravalloti, Nancy; Wylie, Glenn

    2013-01-01

    .... In Experiment 1, functional magnetic resonance imaging (fMRI) was used to examine where in the brain BOLD activity covaried with "state" fatigue, assessed during performance of a task designed to induce cognitive fatigue while in the...

  19. Diffusion tensor magnetic resonance imaging and fiber tractography of the sacral plexus in children with spina bifida

    DEFF Research Database (Denmark)

    Haakma, Wieke; Dik, Pieter; ten Haken, Bennie

    2014-01-01

    PURPOSE: It is still largely unknown how neural tube defects in spina bifida affect the nerves at the level of the sacral plexus. Visualizing the sacral plexus in 3 dimensions could improve our anatomical understanding of neurological problems in patients with spina bifida. We investigated...... anatomical and microstructural properties of the sacral plexus of patients with spina bifida using diffusion tensor imaging and fiber tractography. MATERIALS AND METHODS: Ten patients 8 to 16 years old with spina bifida underwent diffusion tensor imaging on a 3 Tesla magnetic resonance imaging system...... compared to 10 healthy controls. RESULTS: Nerves of patients with spina bifida showed asymmetry and disorganization to a large extent compared to those of healthy controls. Especially at the myelomeningocele level it was difficult to find a connection with the cauda equina. Mean, axial and radial...

  20. Diffusion tensor magnetic resonance imaging and fiber tractography of the sacral plexus in children with spina bifida.

    Science.gov (United States)

    Haakma, Wieke; Dik, Pieter; ten Haken, Bennie; Froeling, Martijn; Nievelstein, Rutger A J; Cuppen, Inge; de Jong, Tom P V M; Leemans, Alexander

    2014-09-01

    It is still largely unknown how neural tube defects in spina bifida affect the nerves at the level of the sacral plexus. Visualizing the sacral plexus in 3 dimensions could improve our anatomical understanding of neurological problems in patients with spina bifida. We investigated anatomical and microstructural properties of the sacral plexus of patients with spina bifida using diffusion tensor imaging and fiber tractography. Ten patients 8 to 16 years old with spina bifida underwent diffusion tensor imaging on a 3 Tesla magnetic resonance imaging system. Anatomical 3-dimensional reconstructions were obtained of the sacral plexus of the 10 patients. Fiber tractography was performed with a diffusion magnetic resonance imaging toolbox to determine fractional anisotropy, and mean, axial and radial diffusivity in the sacral plexus of the patients. Results were compared to 10 healthy controls. Nerves of patients with spina bifida showed asymmetry and disorganization to a large extent compared to those of healthy controls. Especially at the myelomeningocele level it was difficult to find a connection with the cauda equina. Mean, axial and radial diffusivity values at S1-S3 were significantly lower in patients. To our knowledge this 3 Tesla magnetic resonance imaging study showed for the first time sacral plexus asymmetry and disorganization in 10 patients with spina bifida using diffusion tensor imaging and fiber tractography. The observed difference in diffusion values indicates that these methods may be used to identify nerve abnormalities. We expect that this technique could provide a valuable contribution to better analysis and understanding of the problems of patients with spina bifida in the future. Copyright © 2014 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  1. Diffusion tensor magnetic resonance imaging driven growth modeling for radiotherapy target definition in glioblastoma

    DEFF Research Database (Denmark)

    Jensen, Morten B; Guldberg, Trine L; Harbøll, Anja

    2017-01-01

    BACKGROUND: The clinical target volume (CTV) in radiotherapy is routinely based on gadolinium contrast enhanced T1 weighted (T1w + Gd) and T2 weighted fluid attenuated inversion recovery (T2w FLAIR) magnetic resonance imaging (MRI) sequences which have been shown to over- or underestimate...

  2. A Review of Magnetic Resonance Imaging and Diffusion Tensor Imaging Findings in Mild Traumatic Brain Injury

    Science.gov (United States)

    Shenton, ME; Hamoda, HM; Schneiderman, JS; Bouix, S; Pasternak, O; Rathi, Y; M-A, Vu; Purohit, MP; Helmer, K; Koerte, I; Lin, AP; C-F, Westin; Kikinis, R; Kubicki, M; Stern, RA; Zafonte, R

    2013-01-01

    Mild traumatic brain injury (mTBI), also referred to as concussion, remains a controversial diagnosis because the brain often appears quite normal on conventional computed tomography (CT) and magnetic resonance imaging (MRI) scans. Such conventional tools, however, do not adequately depict brain injury in mTBI because they are not sensitive to detecting diffuse axonal injuries (DAI), also described as traumatic axonal injuries (TAI), the major brain injuries in mTBI. Furthermore, for the 15 to 30% of those diagnosed with mTBI on the basis of cognitive and clinical symptoms, i.e., the “miserable minority,” the cognitive and physical symptoms do not resolve following the first three months post-injury. Instead, they persist, and in some cases lead to long-term disability. The explanation given for these chronic symptoms, i.e., postconcussive syndrome, particularly in cases where there is no discernible radiological evidence for brain injury, has led some to posit a psychogenic origin. Such attributions are made all the easier since both post-traumatic stress disorder (PTSD) and depression are frequently co-morbid with mTBI. The challenge is thus to use neuroimaging tools that are sensitive to DAI/TAI, such as diffusion tensor imaging (DTI), in order to detect brain injuries in mTBI. Of note here, recent advances in neuroimaging techniques, such as DTI, make it possible to characterize better extant brain abnormalities in mTBI. These advances may lead to the development of biomarkers of injury, as well as to staging of reorganization and reversal of white matter changes following injury, and to the ability to track and to characterize changes in brain injury over time. Such tools will likely be used in future research to evaluate treatment efficacy, given their enhanced sensitivity to alterations in the brain. In this article we review the incidence of mTBI and the importance of characterizing this patient population using objective radiological measures. Evidence

  3. Diffusion tensor magnetic resonance imaging for single subject diagnosis in neurodegenerative diseases

    National Research Council Canada - National Science Library

    Sajjadi, Seyed A; Acosta-Cabronero, Julio; Patterson, Karalyn; Diaz-de-Grenu, Lara Z; Williams, Guy B; Nestor, Peter J

    2013-01-01

    .... This report presents evidence to indicate that corticobasal degeneration and progressive supranuclear palsy, in particular, might be identifiable at a single subject level with diffusion tensor imaging...

  4. Diffusion tensor magnetic resonance imaging of the brain in APP transgenic mice: a cohort study.

    Directory of Open Access Journals (Sweden)

    Hans-Peter Müller

    Full Text Available INTRODUCTION: Fast in-vivo high resolution diffusion tensor imaging (DTI of the mouse brain has recently been shown to enable cohort studies by the combination of appropriate pulse sequences and cryogenically cooled resonators (CCR. The objective of this study was to apply this DTI approach at the group level to β-amyloid precursor protein (APP transgenic mice. METHODS: Twelve mice (5 wild type, 7 APP transgenic tg2576 underwent DTI examination at 156(2 × 250 µm(3 spatial resolution with a CCR at ultrahigh field (11.7 T. Diffusion images were acquired along 30 gradient directions plus 5 references without diffusion encoding with a total acquisition time of 35 minutes. Fractional anisotropy (FA maps were statistically compared by whole brain-based spatial statistics (WBSS at the group level vs. wild type controls. RESULTS: FA-map comparison showed characteristic regional patterns of differences between the groups with localizations associated with Alzheimer's disease in humans, such as the hippocampus, the entorhinal cortex, and the caudoputamen. CONCLUSION: In this proof-of-principle study, regions associated with amyloid-β deposition could be identified by WBSS of FA maps in APP transgenic mice vs. wild type mice. Thus, DTI in the mouse brain acquired at 11.7 T by use of a CCR was demonstrated to be feasible for cohort studies.

  5. Autism Spectrum Disorder: Does Neuroimaging Support the DSM-5 Proposal for a Symptom Dyad? A Systematic Review of Functional Magnetic Resonance Imaging and Diffusion Tensor Imaging Studies

    Science.gov (United States)

    Pina-Camacho, Laura; Villero, Sonia; Fraguas, David; Boada, Leticia; Janssen, Joost; Navas-Sanchez, Francisco J.; Mayoral, Maria; Llorente, Cloe; Arango, Celso; Parellada, Mara

    2012-01-01

    A systematic review of 208 studies comprising functional magnetic resonance imaging and diffusion tensor imaging data in patients with "autism spectrum disorder" (ASD) was conducted, in order to determine whether these data support the forthcoming DSM-5 proposal of a social communication and behavioral symptom dyad. Studies consistently reported…

  6. The Value of Neurosurgical and Intraoperative Magnetic Resonance Imaging and Diffusion Tensor Imaging Tractography in Clinically Integrated Neuroanatomy Modules: A Cross-Sectional Study

    Science.gov (United States)

    Familiari, Giuseppe; Relucenti, Michela; Heyn, Rosemarie; Baldini, Rossella; D'Andrea, Giancarlo; Familiari, Pietro; Bozzao, Alessandro; Raco, Antonino

    2013-01-01

    Neuroanatomy is considered to be one of the most difficult anatomical subjects for students. To provide motivation and improve learning outcomes in this area, clinical cases and neurosurgical images from diffusion tensor imaging (DTI) tractographies produced using an intraoperative magnetic resonance imaging apparatus (MRI/DTI) were presented and…

  7. Brain changes in long-term zen meditators using proton magnetic resonance spectroscopy and diffusion tensor imaging: a controlled study.

    Science.gov (United States)

    Fayed, Nicolás; Lopez Del Hoyo, Yolanda; Andres, Eva; Serrano-Blanco, Antoni; Bellón, Juan; Aguilar, Keyla; Cebolla, Ausias; Garcia-Campayo, Javier

    2013-01-01

    This work aimed to determine whether (1)H magnetic resonance imaging (MRI), magnetic resonance spectroscopy (MRS), diffusion-weighted imaging (DWI) and diffusion tensor imaging (DTI) are correlated with years of meditation and psychological variables in long-term Zen meditators compared to healthy non-meditator controls. Design. Controlled, cross-sectional study. Sample. Meditators were recruited from a Zen Buddhist monastery. The control group was recruited from hospital staff. Meditators were administered questionnaires on anxiety, depression, cognitive impairment and mindfulness. (1)H-MRS (1.5 T) of the brain was carried out by exploring four areas: both thalami, both hippocampi, the posterior superior parietal lobule (PSPL) and posterior cingulate gyrus. Predefined areas of the brain were measured for diffusivity (ADC) and fractional anisotropy (FA) by MR-DTI. Myo-inositol (mI) was increased in the posterior cingulate gyrus and Glutamate (Glu), N-acetyl-aspartate (NAA) and N-acetyl-aspartate/Creatine (NAA/Cr) was reduced in the left thalamus in meditators. We found a significant positive correlation between mI in the posterior cingulate and years of meditation (r = 0.518; p = .019). We also found significant negative correlations between Glu (r = -0.452; p = .045), NAA (r = -0.617; p = .003) and NAA/Cr (r = -0.448; P = .047) in the left thalamus and years of meditation. Meditators showed a lower Apparent Diffusion Coefficient (ADC) in the left posterior parietal white matter than did controls, and the ADC was negatively correlated with years of meditation (r = -0.4850, p = .0066). The results are consistent with the view that mI, Glu and NAA are the most important altered metabolites. This study provides evidence of subtle abnormalities in neuronal function in regions of the white matter in meditators.

  8. Microstructural changes in thickened corpus callosum in children: contribution of magnetic resonance diffusion tensor imaging

    Energy Technology Data Exchange (ETDEWEB)

    Merlini, Laura; Anooshiravani, Mehrak; Kanavaki, Aikaterini; Hanquinet, Sylviane [University of Geneva Children' s Hospital, Pediatric Radiology Unit, Geneva (Switzerland)

    2015-06-15

    Thickened corpus callosum is a rare finding and its pathophysiology is not well known. An anomalous supracallosal bundle has been depicted by fiber tracking in some cases but no diffusion tensor imaging metrics of thickened corpus callosum have been reported. To use diffusion tensor imaging (DTI) in cases of thickened corpus callosum to help in understanding its clinical significance. During a 7-year period five children (ages 6 months to 15 years) with thickened corpus callosum were studied. We determined DTI metrics of fractional anisotropy (FA), mean diffusivity, and axial (λ1) and radial (λ2, λ3) diffusivity and performed 3-D fiber tracking reconstruction of the thickened corpus callosum. We compared our results with data from the literature and 24 age-matched controls. Brain abnormalities were seen in all cases. All children had at least three measurements of corpus callosum thickness above the 97th percentile according to age. In all children 3-D fiber tracking showed an anomalous supracallosal bundle and statistically significant decrease in FA (P = 0.003) and λ1 (P = 0.001) of the corpus callosum compared with controls, but no significant difference in mean diffusivity and radial diffusivity. Thickened corpus callosum was associated with abnormal bundles, suggesting underlying axonal guidance abnormality. DTI metrics suggested abnormal fiber compactness and density, which may be associated with alterations in cognition. (orig.)

  9. Comparison of Diffusion Tensor Imaging and Magnetic Resonance Perfusion Imaging in Differentiating Recurrent Brain Neoplasm From Radiation Necrosis.

    Science.gov (United States)

    Masch, William R; Wang, Page I; Chenevert, Thomas L; Junck, Larry; Tsien, Christina; Heth, Jason A; Sundgren, Pia C

    2016-05-01

    To compare differences in diffusion tensor imaging (DTI) and dynamic susceptibility-weighted contrast-enhanced (DSC) magnetic resonance (MR) perfusion imaging characteristics of recurrent neoplasm and radiation necrosis in patients with brain tumors previously treated with radiotherapy with or without surgery and chemotherapy. Patients with a history of brain neoplasm previously treated with radiotherapy with or without chemotherapy and surgery who developed a new enhancing lesion on posttreatment surveillance MRI were enrolled. DSC perfusion MRI and DTI were performed. Region of interest cursors were manually drawn in the contrast-enhancing lesions, in the perilesional white matter edema, and in the contralateral normal-appearing frontal lobe white matter. DTI and DSC perfusion MR indices were compared in recurrent tumor versus radiation necrosis. Twenty-two patients with 24 lesions were included. Sixteen (67%) lesions were placed into the recurrent neoplasm group and eight (33%) lesions were placed into the radiation necrosis group using biopsy results as the gold standard in all but three patients. Mean apparent diffusion coefficient values, mean parallel eigenvalues, and mean perpendicular eigenvalues in the contrast-enhancing lesion were significantly lower, and relative cerebral blood volume was significantly higher for the recurrent neoplasm group compared to the radiation necrosis group (P neoplasm from radiation necrosis in patients with a history of brain neoplasm previously treated with radiotherapy with or without surgery and chemotherapy. Copyright © 2016 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  10. 31P nuclear magnetic resonance chemical shielding tensors of phosphorylethanolamine, lecithin, and related compounds: Applications to head-group motion in model membranes.

    Science.gov (United States)

    Kohler, S J; Klein, M P

    1976-03-09

    31P nuclear magnetic resonance (NMR) powder spectra have been used to obtain the principal values of the chemical shielding tensors of dipalmitoyellecithin (DPL), dipalmitoylphosphatidylethanolamine, and several related organophosphate mono- and diesters. In addition, the principal values and orientation of the phosphorylethanolamine shielding tensor were determined from 31P NMR spectra of a single crystal. In all compounds studied the shielding tensors were clearly monaxial. The monoester spectra are typified by the spectrum of phosphorylethanolamine with principal values of -67, -13, and 69 ppm relative to H3PO4. The diesters have a larger total anisotrophy, as indicated by the DPL values of -81, -25, and 108 ppm. These data as well as the orientation of the phosphorylethanolamine shielding tensor are correlated with the electron density distribution as determined by the bonding pattern of the phosphate. The spectrum of a DPL-water (1:1) mixture at 52 degrees C has a shift anisotrophy of 30 ppm and displays a shape characteristic of an axial tensor. This change from the rigid lattice DPL pattern is explained in terms of motional narrowing, and the shielding tensor data are used to interpret the motion of the phospholipid head group. Simple rotation about the P-O(glycerol) bond is excluded, and a more complex motion involving rotation about both the P-O (glycerol) and glycerol C(2)-C(3) bonds is postulated.

  11. /sup 31/P nuclear magnetic resonance chemical shielding tensors of phosphorylethanolamine, lecithin, and related compounds: applications to head-group motion in model membranes

    Energy Technology Data Exchange (ETDEWEB)

    Kohler, S.J.; Klein, M.P.

    1976-03-09

    /sup 31/P nuclear magnetic resonance (NMR) power spectra have been used to obtain the principal values of the chemical shielding tensors of dipalmitoyllecithin (DPL), dipalmitoylphosphatidylethanolamine, and several related organophosphate mono- and diesters. In addition, the principal values and orientation of the phosphorylethanolamine shielding tensor were determined from /sup 31/P NMR spectra of a single crystal. In all compounds studied the shielding tensors were clearly nonaxial. The monoester spectra are typified by the spectrum of phosphorylethanolamine with principal values of -67, -13, and 69 ppm relative to H/sub 3/PO/sub 4/. The diesters have a larger total anisotropy, as indicated by the DPL values of -81, -25, and 108 ppm. These data as well as the orientation of the phosphorylethanolamine shielding tensor are correlated with the electron density distribution as determined by the bonding pattern of the phosphate. The spectrum of a DPL--water (1:1) mixture at 52/sup 0/C has a shift anisotropy of 30 ppm and displays a shape characteristic of an axial tensor. This change from the rigid lattice DPL pattern is explained in terms of motional narrowing, and the shielding tensor data are used to interpret the motion of the phospholipid head group. Simple rotation about the P--O(glycerol) bond is excluded, and a more complex motion involving rotation about both the P--O(glycerol) and glycerol C(2)--C(3) bonds is postulated. (auth)

  12. Experimental evaluation of electrical conductivity imaging of anisotropic brain tissues using a combination of diffusion tensor imaging and magnetic resonance electrical impedance tomography

    Directory of Open Access Journals (Sweden)

    Saurav Z. K. Sajib

    2016-06-01

    Full Text Available Anisotropy of biological tissues is a low-frequency phenomenon that is associated with the function and structure of cell membranes. Imaging of anisotropic conductivity has potential for the analysis of interactions between electromagnetic fields and biological systems, such as the prediction of current pathways in electrical stimulation therapy. To improve application to the clinical environment, precise approaches are required to understand the exact responses inside the human body subjected to the stimulated currents. In this study, we experimentally evaluate the anisotropic conductivity tensor distribution of canine brain tissues, using a recently developed diffusion tensor-magnetic resonance electrical impedance tomography method. At low frequency, electrical conductivity of the biological tissues can be expressed as a product of the mobility and concentration of ions in the extracellular space. From diffusion tensor images of the brain, we can obtain directional information on diffusive movements of water molecules, which correspond to the mobility of ions. The position dependent scale factor, which provides information on ion concentration, was successfully calculated from the magnetic flux density, to obtain the equivalent conductivity tensor. By combining the information from both techniques, we can finally reconstruct the anisotropic conductivity tensor images of brain tissues. The reconstructed conductivity images better demonstrate the enhanced signal intensity in strongly anisotropic brain regions, compared with those resulting from previous methods using a global scale factor.

  13. Experimental evaluation of electrical conductivity imaging of anisotropic brain tissues using a combination of diffusion tensor imaging and magnetic resonance electrical impedance tomography

    Energy Technology Data Exchange (ETDEWEB)

    Sajib, Saurav Z. K.; Jeong, Woo Chul; Oh, Tong In; Kim, Hyung Joong, E-mail: bmekim@khu.ac.kr, E-mail: ejwoo@khu.ac.kr; Woo, Eung Je, E-mail: bmekim@khu.ac.kr, E-mail: ejwoo@khu.ac.kr [Department of Biomedical Engineering, Kyung Hee University, Seoul 02447 (Korea, Republic of); Kyung, Eun Jung [Department of Pharmacology, Chung-Ang University, Seoul 06974 (Korea, Republic of); Kim, Hyun Bum [Department of East-West Medical Science, Kyung Hee University, Yongin 17104 (Korea, Republic of); Kwon, Oh In [Department of Mathematics, Konkuk University, Seoul 05029 (Korea, Republic of)

    2016-06-15

    Anisotropy of biological tissues is a low-frequency phenomenon that is associated with the function and structure of cell membranes. Imaging of anisotropic conductivity has potential for the analysis of interactions between electromagnetic fields and biological systems, such as the prediction of current pathways in electrical stimulation therapy. To improve application to the clinical environment, precise approaches are required to understand the exact responses inside the human body subjected to the stimulated currents. In this study, we experimentally evaluate the anisotropic conductivity tensor distribution of canine brain tissues, using a recently developed diffusion tensor-magnetic resonance electrical impedance tomography method. At low frequency, electrical conductivity of the biological tissues can be expressed as a product of the mobility and concentration of ions in the extracellular space. From diffusion tensor images of the brain, we can obtain directional information on diffusive movements of water molecules, which correspond to the mobility of ions. The position dependent scale factor, which provides information on ion concentration, was successfully calculated from the magnetic flux density, to obtain the equivalent conductivity tensor. By combining the information from both techniques, we can finally reconstruct the anisotropic conductivity tensor images of brain tissues. The reconstructed conductivity images better demonstrate the enhanced signal intensity in strongly anisotropic brain regions, compared with those resulting from previous methods using a global scale factor.

  14. Diffusion tensor imaging applications in multiple sclerosis patients using 3T magnetic resonance: a preliminary study

    Energy Technology Data Exchange (ETDEWEB)

    Testaverde, Lorenzo; Caporali, Laura [University ' ' Sapienza' ' of Rome, Department of Radiological Sciences, Rome (Italy); Venditti, Eugenio; Grillea, Giovanni [U.O.C. Neuroradiologia, I.R.C.C.S. ' ' Neuromed' ' , Pozzilli (Italy); Colonnese, Claudio [University ' ' Sapienza' ' of Rome, Department of Radiological Sciences, Rome (Italy); U.O.C. Neuroradiologia, I.R.C.C.S. ' ' Neuromed' ' , Pozzilli (Italy)

    2012-05-15

    This study evaluated patients with multiple sclerosis using diffusion tensor imaging (DTI) to obtain fractional anisotropy (FA) and mean diffusivity (MD) values. We investigated the possible statistically significant variation of MD and FA in different MS patients, compared simultaneously, putting in comparison their normal appearing white matter (NAWM) and white matter affected by disease (plaques), both during activity and in remission, with normal white matter (NWM) of control subjects. Statistical analysis using Levene's test for comparison of variances revealed significant (P < 0.05) differences between FA values of the NWM of the controls and those of NAWM and active or inactive lesions, of the patients in the study. However, the differences between MD values of the NWM of the controls and those of NAWM and active or inactive lesions of the patients in the study were judged not significant (P > 0.05). Imaging of MS using MRI techniques is constantly searching for reproducible quantitative parameter. This study shows how these parameters can be identified in the MD and FA values, and thus suggests the implementation of MRI routine protocols for diagnosing MS with the DTI analysis, since it can provide valuable information otherwise unobtainable. (orig.)

  15. Reproducibility of in-vivo diffusion tensor cardiovascular magnetic resonance in hypertrophic cardiomyopathy

    Directory of Open Access Journals (Sweden)

    McGill Laura-Ann

    2012-12-01

    Full Text Available Abstract Background Myocardial disarray is an important histological feature of hypertrophic cardiomyopathy (HCM which has been studied post-mortem, but its in-vivo prevalence and extent is unknown. Cardiac Diffusion Tensor Imaging (cDTI provides information on mean intravoxel myocyte orientation and potentially myocardial disarray. Recent technical advances have improved in-vivo cDTI, and the aim of this study was to assess the interstudy reproducibility of quantitative in-vivo cDTI in patients with HCM. Methods and results A stimulated-echo single-shot-EPI sequence with zonal excitation and parallel imaging was implemented. Ten patients with HCM were each scanned on 2 different days. For each scan 3 short axis mid-ventricular slices were acquired with cDTI at end systole. Fractional anisotropy (FA, mean diffusivity (MD, and helix angle (HA maps were created using a cDTI post-processing platform developed in-house. The mean ± SD global FA was 0.613 ± 0.044, MD was 0.750 ± 0.154 × 10-3 mm2/s and HA was epicardium −34.3 ± 7.6°, mesocardium 3.5 ± 6.9° and endocardium 38.9 ± 8.1°. Comparison of initial and repeat studies showed global interstudy reproducibility for FA (SD = ± 0.045, Coefficient of Variation (CoV = 7.2%, MD (SD = ± 0.135 × 10-3 mm2/s, CoV = 18.6% and HA (epicardium SD = ± 4.8°; mesocardium SD = ± 3.4°; endocardium SD = ± 2.9°. Reproducibility of FA was superior to MD (p = 0.003. Global MD was significantly higher in the septum than the reference lateral wall (0.784 ± 0.188 vs 0.750 ± 0.154 x10-3 mm2/s, p  Conclusions To the best of our knowledge, this is the first study to assess the interstudy reproducibility of DTI in the human HCM heart in-vivo and the largest cDTI study in HCM to date. Our results show good reproducibility of FA, MD and HA which indicates that current technology yields robust in-vivo measurements that have potential clinical value. The

  16. Role of diffusion tensor imaging or magnetic resonance spectroscopy in the diagnosis and disability assessment of amyotrophic lateral sclerosis.

    Science.gov (United States)

    Liu, Chanchan; Jiang, Rifeng; Yi, Xiyan; Zhu, Wenzhen; Bu, Bitao

    2015-01-15

    To compare the results of magnetic resonance spectroscopy (MRS) and diffusion tensor imaging (DTI) in amyotrophic lateral sclerosis (ALS) patients. Nineteen ALS patients and thirteen age-matched healthy controls underwent MRS and DTI between October 2013 and July 2014. Fractional anisotropy (FA), apparent diffusion coefficient (ADC), N-acetylaspartate (NAA), choline (Cho), and creatine (Cr) were collected as the quantitative results of the imaging study. The ALS functional rating scale-revised (ALSFRS-R) and disease progression rate were evaluated to assess patients' disability. The imaging study results were compared between ALS patients and healthy controls. The relationship between disability assessment and imaging study results was analyzed. NAA/Cr in the motor cortex and FA in the corticospinal tract (CST) of both sides were significantly lower in patients than controls. There was no significant difference between the two groups in Cho/Cr, tract length, tract volume, ADC or NAA. No relationship was found between ALSFRS-R and FA (r=0.243, p=0.316) in the right CST; NAA (r=0.095, p=0.699) or NAA/Cr (r=0.172, p=0.481) in the left motor cortex; or NAA (r=0.320, p=0.182) or NAA/Cr (r=0.193, p=0.492) in the right motor cortex. There was no relationship between the disease progression rate and FA, NAA, or NAA/Cr on either side. NAA/Cr and FA can help diagnose ALS. Regional brain NAA/Cr and FA values could not assess the ALSFRS-R or disease progression rate. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. Differences between proximal versus distal intraorbital optic nerve diffusion tensor magnetic resonance imaging properties in glaucoma patients.

    Science.gov (United States)

    Bolacchi, Francesca; Garaci, Francesco Giuseppe; Martucci, Alessio; Meschini, Alessandro; Fornari, Maria; Marziali, Simone; Mancino, Raffaele; Squillaci, Ettore; Floris, Roberto; Cerulli, Luciano; Simonetti, Giovanni; Nucci, Carlo

    2012-06-28

    To analyze in vivo the diffusion tensor magnetic resonance imaging (DT-MRI) properties of the intraorbital optic nerve at two different levels: Proximal to the optic nerve head (ONH) and distal to the ONH at the level of the orbital apex in glaucoma patients. Twenty-four patients with primary open-angle glaucoma were examined. The categorization into early and severe glaucoma was performed by Hodapp's classification. Fifteen healthy individuals served as controls. DT-MRI was performed with a 3T-MR unit. At early stage mean diffusivity (MD) values were higher at the proximal site with respect to the distal site. On the contrary, a decrease in fractional anisotropy (FA) was observed only relative to patient stage, independent of optic nerve site. Moreover, at early disease stage an increase in overall diffusivities, was evident at the proximal site, whereas at the distal site a decrease of the largest diffusivity and an increase in both the intermediate and smallest diffusivities were observed. FA and MD measured at the proximal site, had, respectively, the highest sensitivity and specificity in discriminating between healthy and glaucomatous eyes. Our study represents the first attempt to evaluate in vivo fiber integrity changes along the optic nerve with DT-MRI. Optic nerve degeneration appears to be a process that affects differently the proximal and the distal segments of the optic nerve. The complementary high sensitivity of FA with the high specificity of MD at the proximal site may provide reliable indexes for the identification of glaucomatous patients at early stages.

  18. Ab Initio Calculation of Nuclear Magnetic Resonance Chemical Shift Anisotropy Tensors 1. Influence of Basis Set on the Calculation of 31P Chemical Shifts

    Energy Technology Data Exchange (ETDEWEB)

    Alam, T.M.

    1998-09-01

    The influence of changes in the contracted Gaussian basis set used for ab initio calculations of nuclear magnetic resonance (NMR) phosphorous chemical shift anisotropy (CSA) tensors was investigated. The isotropic chemical shitl and chemical shift anisotropy were found to converge with increasing complexity of the basis set at the Hartree-Fock @IF) level. The addition of d polarization function on the phosphorous nucIei was found to have a major impact of the calculated chemical shi~ but diminished with increasing number of polarization fimctions. At least 2 d polarization fimctions are required for accurate calculations of the isotropic phosphorous chemical shift. The introduction of density fictional theory (DFT) techniques through tie use of hybrid B3LYP methods for the calculation of the phosphorous chemical shift tensor resulted in a poorer estimation of the NMR values, even though DFT techniques result in improved energy and force constant calculations. The convergence of the W parametem with increasing basis set complexity was also observed for the DFT calculations, but produced results with consistent large deviations from experiment. The use of a HF 6-31 l++G(242p) basis set represents a good compromise between accuracy of the simulation and the complexity of the calculation for future ab initio calculations of 31P NMR parameters in larger complexes.

  19. Magnetic resonance diffusion tensor imaging (MRDTI) of the optic nerve and optic radiations at 3T in children with neurofibromatosis type I (NF-1)

    Energy Technology Data Exchange (ETDEWEB)

    Filippi, Christopher G.; Nickerson, Joshua P. [University of Vermont School of Medicine-FAHC, Department of Radiology, Burlington, VT (United States); Bos, Aaron [University of Vermont School of Medicine, Burlington, VT (United States); Salmela, Michael B. [University of Minnesota School of Medicine, Department of Radiology, Minneapolis, MN (United States); Koski, Chris J. [James Madison University, Department of Political Sciences, Harrisonburg, VA (United States); Cauley, Keith A. [University of Massachusetts Memorial Medical Center, Department of Radiology, Worcester, MA (United States)

    2012-02-15

    Optic pathway glioma (OPG) is a characteristic hallmark of neurofibromatosis type I (NF-I). To evaluate the feasibility of magnetic resonance diffusion tensor imaging (MRDTI) at 3T to detect abnormalities of the optic nerves and optic radiations in children with NF-I. 3-T MRDTI was prospectively performed in 9 children with NF-I (7 boys, 2 girls, average age 7.8 years, range 3-17 years) and 44 controls (25 boys, 19 girls, average age 8.1 years, range 3-17 years). Fractional anisotropy (FA) and mean diffusivity were determined by region-of-interest analysis for the optic nerves and radiations. Statistical analysis compared controls to NF-I patients. Two NF-I patients had bilateral optic nerve gliomas, three had chiasmatic gliomas and four had unidentified neurofibromatosis objects (UNOs) along the optic nerve pathways. All NF-I patients had statistically significant decreases in FA and elevations in mean diffusivity in the optic nerves and radiations compared to age-matched controls. MRDTI can evaluate the optic pathways in children with NF-I. Statistically significant abnormalities were detected in the diffusion tensor metrics of the optic nerves and radiations in children with NF-I compared to age-matched controls. (orig.)

  20. Evaluation of the Differences of Myocardial Fibers between Acute and Chronic Myocardial Infarction: Application of Diffusion Tensor Magnetic Resonance Imaging in a Rhesus Monkey Model

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Yuqing [Department of Radiology, West China Hospital, Sichuan University, Sichuan 610041 (China); CAS Key Laboratory for Biomedical Effects of Nanomaterials and Nanosafety, National Center for Nanoscience and Technology of China, Beijing 100190 (China); Cai, Wei [Department of Radiology, West China Hospital, Sichuan University, Sichuan 610041 (China); Department of Radiology, Beijing Jishuitan Hospital, 4th Clinical Medical College of Peking University, Beijing 100035 (China); Wang, Lei [Department of Radiology, West China Hospital, Sichuan University, Sichuan 610041 (China); Xia, Rui [Department of Radiology, West China Hospital, Sichuan University, Sichuan 610041 (China); Department of Radiology, The First Affiliated Hospital, Chongqing Medical University, Chongqing 400016 (China); Chen, Wei [Department of Radiology, West China Hospital, Sichuan University, Sichuan 610041 (China); Department of Radiology, The First Affiliated Hospital of Kunming Medical University, Yunnan 650032 (China); Zheng, Jie [Mallinckrodt Institute of Radiology, School of Medicine, Washington University, St. Louis, MO 63110 (United States); Gao, Fabao [Department of Radiology, West China Hospital, Sichuan University, Sichuan 610041 (China)

    2016-11-01

    To understand microstructural changes after myocardial infarction (MI), we evaluated myocardial fibers of rhesus monkeys during acute or chronic MI, and identified the differences of myocardial fibers between acute and chronic MI. Six fixed hearts of rhesus monkeys with left anterior descending coronary artery ligation for 1 hour or 84 days were scanned by diffusion tensor magnetic resonance imaging (MRI) to measure apparent diffusion coefficient (ADC), fractional anisotropy (FA) and helix angle (HA). Comparing with acute MI monkeys (FA: 0.59 ± 0.02; ADC: 5.0 ± 0.6 × 10{sup -4} mm{sup 2}/s; HA: 94.5 ± 4.4°), chronic MI monkeys showed remarkably decreased FA value (0.26 ± 0.03), increased ADC value (7.8 ± 0.8 × 10{sup -4}mm{sup 2}/s), decreased HA transmural range (49.5 ± 4.6°) and serious defects on endocardium in infarcted regions. The HA in infarcted regions shifted to more components of negative left-handed helix in chronic MI monkeys (-38.3 ± 5.0°–11.2 ± 4.3°) than in acute MI monkeys (-41.4 ± 5.1°–53.1 ± 3.7°), but the HA in remote regions shifted to more components of positive right-handed helix in chronic MI monkeys (-43.8 ± 2.7°–66.5 ± 4.9°) than in acute MI monkeys (-59.5 ± 3.4°–64.9 ± 4.3°). Diffusion tensor MRI method helps to quantify differences of mechanical microstructure and water diffusion of myocardial fibers between acute and chronic MI monkey's models.

  1. Evaluation of the differences of myocardial fibers between acute and chronic myocardial infarction: Application of diffusion tensor magnetic resonance imaging INA Rhesus monkey model

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Yu Qing; Cai, Wei; Wang, Lei; Xia, Rui; Chen, Wei; Zheng, Jie [Dept. of Radiology, West China Hospital, Sichuan University, Sichuan (China); Gao, Fabao [Mallinckrodt Institute of Radiology, School of Medicine, Washington University, St. Louis (United States)

    2016-09-15

    To understand microstructural changes after myocardial infarction (MI), we evaluated myocardial fibers of rhesus monkeys during acute or chronic MI, and identified the differences of myocardial fibers between acute and chronic MI. Six fixed hearts of rhesus monkeys with left anterior descending coronary artery ligation for 1 hour or 84 days were scanned by diffusion tensor magnetic resonance imaging (MRI) to measure apparent diffusion coefficient (ADC), fractional anisotropy (FA) and helix angle (HA). Comparing with acute MI monkeys (FA: 0.59 ± 0.02; ADC: 5.0 ± 0.6 × 10{sup -4} mm{sup 2}/s; HA: 94.5 ± 4.4°), chronic MI monkeys showed remarkably decreased FA value (0.26 ± 0.03), increased ADC value (7.8 ± 0.8 × 10{sup -4} mm{sup 2}/s), decreased HA transmural range (49.5 ± 4.6°) and serious defects on endocardium in infarcted regions. The HA in infarcted regions shifted to more components of negative left-handed helix in chronic MI monkeys (-38.3 ± 5.0°–11.2 ± 4.3°) than in acute MI monkeys (-41.4 ± 5.1°–53.1 ± 3.7°), but the HA in remote regions shifted to more components of positive right-handed helix in chronic MI monkeys (-43.8 ± 2.7°–66.5 ± 4.9°) than in acute MI monkeys (-59.5 ± 3.4°–64.9 ± 4.3°). Diffusion tensor MRI method helps to quantify differences of mechanical microstructure and water diffusion of myocardial fibers between acute and chronic MI monkey's models.

  2. Age-related decline in white matter integrity in a mouse model of tauopathy: an in vivo diffusion tensor magnetic resonance imaging study

    Science.gov (United States)

    Sahara, Naruhiko; Perez, Pablo D.; Lin, Wen-Lang; Dickson, Dennis W.; Ren, Yan; Zeng, Huadong; Lewis, Jada; Febo, Marcelo

    2016-01-01

    Elevated expression of human hyperphosphorylated tau is associated with neuronal loss and white matter (WM) pathology in Alzheimer’s disease (AD) and related neurodegenerative disorders. Using in vivo diffusion tensor magnetic resonance imaging (DT-MRI) at 11.1 Tesla we measured age-related alterations in WM diffusion anisotropy indices in a mouse model of human tauopathy (rTg4510) and nontransgenic (nonTg) control mice at the age of 2.5, 4.5, and 8 months. Similar to previous DT-MRI studies in AD subjects, 8-month-old rTg4510 mice showed lower fractional anisotropy (FA) values in WM structures than nonTg. The low WM FA in rTg4510 mice was observed in the genu and splenium of the corpus callosum, anterior commissure, fimbria, and internal capsule and was associated with a higher radial diffusivity than nonTg. Interestingly, rTg4510 mice showed lower estimates for the mode of anisotropy than controls at 2.5 months suggesting that changes in this diffusivity metric are detectable at an early stage preceding severe tauopathy. Immunogold electron microscopy partly supports our diffusion tensor imaging findings. At the age of 4 months, rTg4510 mice show axonal tau inclusions and unmyelinated processes. At later ages (12 months and 14 months) we observed inclusions in myelin sheath, axons, and unmyelinated processes, and a “disorganized” pattern of myelinated fiber arrangement with enlarged inter-axonal spaces in rTg4510 but not in nonTg mice. Our data support a role for the progression of tau pathology in reduced WM integrity measured by DT-MRI. Further in vivo DT-MRI studies in the rTg4510 mouse should help better discern the detailed mechanisms of reduced FA and anisotropy mode, and the specific role of tau during neurodegeneration. PMID:24411290

  3. Primary granulomatous angiitis of the central nervous system: findings of magnetic resonance spectroscopy and fractional anisotropy in diffusion tensor imaging prior to surgery. Case report.

    Science.gov (United States)

    Beppu, Takaaki; Inoue, Takashi; Nishimoto, Hideaki; Nakamura, Shinichi; Nakazato, Yoichi; Ogasawara, Kuniaki; Ogawa, Akira

    2007-10-01

    Primary granulomatous angiitis of the central nervous system (CNS) is extremely rare. Its preoperative diagnosis is difficult as the condition displays nonspecific features on routine neuroimaging investigations. In this paper, the authors report findings of magnetic resonance (MR) spectroscopy and fractional anisotropy (FA) with diffusion tensor MR imaging in a case of granulomatous angiitis of the CNS. A 30-year-old man presented with morning headaches and grand mal seizures. An MR image revealed a mass resembling glioblastoma in the right temporal lobe. Magnetic resonance spectroscopy showed a high choline/creatine (Cho/Cr) ratio indicative of a malignant neoplasm, accompanied by a slight elevation of glutamate and glutamine. The FA value was very low, which is inconsistent with malignant glioma. The mass was totally removed surgically. Histologically, the peripheral lesion of the mass consisted of a rough accumulation of fat granule cells, infiltration of inflammatory cells, and distribution of capillary vessels. Some vessels within the lesion were replaced by granulomas. The histological diagnosis was granulomatous angiitis of the CNS. The MIB-1-positive rate of the granuloma was approximately 5%. Both MR spectroscopy and FA were unable to accurately diagnose granulomatous angiitis of the CNS prior to surgery; however, elevated Cho/Cr and glutamate and glutamine shown by MR spectroscopy may indicate the moderate proliferation potential of the granuloma and the inflammatory process, respectively, in this condition. Although the low FA value in the present case enabled the authors to rule out a diagnosis of glioblastoma, FA values in inflammatory lesions require careful interpretation.

  4. Diffusion tensor magnetic resonance imaging for hand and foot fibers location at the corona radiata: comparison with two lesion studies

    Directory of Open Access Journals (Sweden)

    Dong-Hoon eLee

    2014-09-01

    Full Text Available The corticospinal tract is the motor pathway in the human brain, and corona radiata is an important location to diagnose stroke. We detected hand and foot motor fiber tracts in the corona radiata to investigate accurate locations using diffusion tensor imaging and functional imaging. Ten right-handed normal volunteers participated in this study. We used a probabilistic tracking algorithm, a brain normalization method, and functional imaging results to set out ROIs. Moreover, our results were compared to previous results of lesion studies to confirm their accuracy and usefulness. The location measurements were performed in two index types; anteriority index on the basis of the anterior and posterior location of lateral ventricle, laterality index on the basis of the left and right location. The anteriority indices were 56.40/43.2 (hand/foot at the upper CR and lower CR 40.72/30.90 at the lower CR. The measurements of anteriority and laterality of motor fibers were represented as anteriority index 0.40/0.31 and laterality index 0.60/0.47 (hand/foot. Our results showed that the hand and foot fibers were in good agreements with previous lesion studies. This study and approaches can be used as a standard for diffusion tensor image combined with lesion location studies in patients who need rehabilitation or follow up.

  5. Magnetic resonance diffusion tensor imaging and tractography of intracranial cavernous malformations: preliminary observations and characterization of the hemosiderin rim.

    Science.gov (United States)

    Cauley, Keith A; Andrews, Trevor; Gonyea, Jay V; Filippi, Christopher G

    2010-04-01

    Cavernous malformations (CMs) can cause symptoms that appear out of proportion to the lesion size, leading one to hypothesize that they may have an effect on adjacent white matter that is not fully explained by local mass effect. The goal of this study was to investigate the diffusion tensor (DT) properties of CMs, the hemosiderin rim, and normal-appearing adjacent white matter. Eighteen cavernous malformations were characterized using standard MR imaging sequences as well as 6-direction DT imaging with single-shot echo planar-gradient echo imaging at 3 tesla. Diffusion tensor imaging demonstrated that CMs have a characteristic signature on DT imaging, with low fractional anisotropy (FA) and high mean diffusivity centrally within the lesion. The hemosiderin rim had a high FA value relative to the central lesion or adjacent white matter. Tractography revealed that tracts neatly deviate around CMs. Tracts were typically seen to pass through the hemosiderin rim. The hemosiderin rim of CMs was intimately associated with white matter tracts that were deviated by the central lesion. These findings are consistent with histopathological reports that the hemosiderin rim is composed of blood breakdown products deposited in viable white matter.

  6. Magnetic Resonance (MR) Defecography

    Science.gov (United States)

    ... Physician Resources Professions Site Index A-Z Magnetic Resonance (MR) Defecography Magnetic resonance (MR) defecography is a ... the limitations of MRI defecography? What is magnetic resonance (MR) defecography? Magnetic resonance imaging (MRI) is a ...

  7. In vivo assessment of putative functional placental tissue volume in placental intrauterine growth restriction (IUGR) in human fetuses using diffusion tensor magnetic resonance imaging.

    Science.gov (United States)

    Javor, D; Nasel, C; Schweim, T; Dekan, S; Chalubinski, K; Prayer, D

    2013-08-01

    Intrauterine growth restriction (IUGR) is a diagnostic challenge, since ultrasound fetal biometry (UFB) provides only a 50% detection rate for IUGR. This may be attributable to the fact that UFB does not allow a direct evaluation of functional placental tissue. We hypothesized that direct assessment, using magnetic resonance diffusion tensor imaging (DT-MRI), can provide better detection of IUGR by reliably distinguishing between normal and non-functional placental tissue. Patients with normal placenta function (n = 21) and suspected IUGR (n = 14) according to UFB were examined. DT-MRI-based properties of areas of the placenta that were judged to represent normal functional tissue, in normal pregnancies, were used to perform volumetry of the putative functional placental tissue (PFPT) in a control- and an IUGR-group. Fractional anisotropy (FRC), as well as maximum and mean diffusivity were also calculated. PFPT volumetry showed a significant reduction of functional placental tissue in the IUGR group of up to 33%. Analysis of global PFPT, maximum diffusivity, mean diffusivity, and FRC also showed a significant difference. PFPT volume is dramatically reduced in IUGR. Several DT-MRI parameters suggest an additional placental micro-architecture disturbance in IUGR. PFPT volumetry appears to be a promising tool for improving the detection of IUGR. Copyright © 2013 Elsevier Ltd. All rights reserved.

  8. Effect of a weak static magnetic field on nitrogen-14 quadrupole resonance in the case of an axially symmetric electric field gradient tensor.

    Science.gov (United States)

    Guendouz, Laouès; Aissani, Sarra; Marêché, Jean-François; Retournard, Alain; Marande, Pierre-Louis; Canet, Daniel

    2013-01-01

    The application of a weak static B0 magnetic field (less than 1 mT) may produce a well-defined splitting of the (14)N Quadrupole Resonance line when the electric field gradient tensor at the nitrogen nucleus level is of axial symmetry. It is theoretically shown and experimentally confirmed that the actual splitting (when it exists) as well as the line-shape and the signal intensity depends on three factors: (i) the amplitude of B0, (ii) the amplitude and pulse duration of the radio-frequency field, B1, used for detecting the NQR signal, and (iii) the relative orientation of B0 and B1. For instance, when B0 is parallel to B1 and regardless of the B0 value, the signal intensity is three times larger than when B0 is perpendicular to B1. This point is of some importance in practice since NQR measurements are almost always performed in the earth field. Moreover, in the course of this study, it has been recognized that important pieces of information regarding line-shape are contained in data points at the beginning of the free induction decay (fid) which, in practice, are eliminated for avoiding spurious signals due to probe ringing. It has been found that these data points can generally be retrieved by linear prediction (LP) procedures. As a further LP benefit, the signal intensity loss (by about a factor of three) is regained. © 2013 Published by Elsevier Inc.

  9. Abnormal functional-structural cingulum connectivity in mania: combined functional magnetic resonance imaging-diffusion tensor imaging investigation in different phases of bipolar disorder.

    Science.gov (United States)

    Martino, M; Magioncalda, P; Saiote, C; Conio, B; Escelsior, A; Rocchi, G; Piaggio, N; Marozzi, V; Huang, Z; Ferri, F; Amore, M; Inglese, M; Northoff, G

    2016-10-01

    The objective of the study was to investigate the relationship between structural connectivity (SC) and functional connectivity (FC) in the cingulum in bipolar disorder (BD) and its various phases. We combined resting-state functional magnetic resonance imaging and probabilistic tractographic diffusion tensor imaging to investigate FC and SC of the cingulum and its portions, the SC-FC relationship, and their correlations with clinical and neurocognitive measures on sustained attention in manic (n = 21), depressed (n = 20), and euthymic (n = 20) bipolar patients and healthy controls (HC) (n = 42). First, we found decreased FC between the anterior and posterior parts of the cingulum in manic patients when compared to depressed patients and HC. Second, we observed decreased SC of the cingulum bundle, particularly in its anterior part, in manic patients when compared to HC. Finally, alterations in the cingulum FC (but not SC) correlated with clinical severity scores while changes in the cingulum SC (but not FC) were related with neurocognitive deficits in sustained attention in BD. We demonstrate for the first time a reduction in FC and concomitantly in SC of the cingulum in mania, which correlated with psychopathological and neurocognitive parameters, respectively, in BD. This supports the central role of cingulum connectivity specifically in mania. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  10. The value of neurosurgical and intraoperative magnetic resonance imaging and diffusion tensor imaging tractography in clinically integrated neuroanatomy modules: a cross-sectional study.

    Science.gov (United States)

    Familiari, Giuseppe; Relucenti, Michela; Heyn, Rosemarie; Baldini, Rossella; D'Andrea, Giancarlo; Familiari, Pietro; Bozzao, Alessandro; Raco, Antonino

    2013-01-01

    Neuroanatomy is considered to be one of the most difficult anatomical subjects for students. To provide motivation and improve learning outcomes in this area, clinical cases and neurosurgical images from diffusion tensor imaging (DTI) tractographies produced using an intraoperative magnetic resonance imaging apparatus (MRI/DTI) were presented and discussed during integrated second-year neuroanatomy, neuroradiology, and neurosurgery lectures over the 2008-2011 period. Anonymous questionnaires, evaluated according to the Likert scale, demonstrated that students appreciated this teaching procedure. Academic performance (examination grades for neuroanatomy) of the students who attended all integrated lectures of neuroanatomy, was slightly though significantly higher compared to that of students who attended these lectures only occasionally or not at all (P=0.04). Significantly better results were obtained during the national progress test (focusing on morphology) by students who attended the MRI/DTI-assisted lectures, compared to those who did so only in part or not at all, compared to the average student participating in the national test. These results were obtained by students attending the second, third and, in particular, the fourth year (P≤0.0001) courses during the three academic years mentioned earlier. This integrated neuroanatomy model can positively direct students in the direction of their future professional careers without any extra expense to the university. In conclusion, interactive learning tools, such as lectures integrated with intraoperative MRI/DTI images, motivate students to study and enhance their neuroanatomy education. Copyright © 2013 American Association of Anatomists.

  11. Evaluate the early changes of myocardial fibers in rhesus monkey during sub-acute stage of myocardial infarction using diffusion tensor magnetic resonance imaging.

    Science.gov (United States)

    Wang, Yuqing; Cai, Wei; Wang, Lei; Xia, Rui

    2016-05-01

    The deterioration of cardiac mechanical function starts from the micro-alterations in the myocardial fibers after myocardial infarction (MI) due to the heart beats derived from the systole and diastole of the myocardial fibers. So, we want to evaluate quantitatively the early changes of myocardial fibers in rhesus monkey during sub-acute MI stage. Three fixed hearts with infarction after left anterior descending coronary artery ligation for 7days and eight age-matched intact controls were scanned by ex-vivo diffusion tensor magnetic resonance imaging (DT-MRI) to measure apparent diffusion coefficient (ADC), fractional anisotropy (FA) and helix angle (HA). In comparison with healthy controls, FA and transmural range of HA in MI regions showed a significant reduction whereas ADC showed a significant increment (pmyocardial fibers shifted further to left-handed helix around the infarcted and adjacent myocardium but shifted further to right-handed helix in remote myocardium. HA is sensitive to evaluate quantitatively the early changes of myocardial fibers in sub-acute MI rhesus monkeys. The myocardial fibers in normal monkeys are similar to those in normal humans, suggesting that early changes of myocardial fibers in sub-acute MI monkeys can contribute to more accurately understand those in patients suffering sub-acute MI. Copyright © 2015 Elsevier Inc. All rights reserved.

  12. A combination of functional magnetic resonance imaging and diffusion tensor image to explore structure–function relationship in healthy and myelopathic spinal cord

    Directory of Open Access Journals (Sweden)

    Cui JL

    2016-10-01

    Full Text Available Jiao-Long Cui,1 Guangsheng Li,2 Kin-Cheung Mak,1,3 Keith Dip-Kei Luk,1 Yong Hu1-3 1Department of Orthopaedics and Traumatology, The University of Hong Kong, Hong Kong, People’s Republic of China; 2Department of Orthopaedics, Spinal Division, Affiliated Hospital of Guangdong Medical University, Guangdong, 3Shenzhen Key Laboratory for Innovative Technology in Orthopaedic Trauma, The University of Hong Kong-Shenzhen Hospital, Shenzhen, People’s Republic of China Background: Cervical spondylotic myelopathy (CSM is a degenerative disorder that can chronically damage the spinal cord. The aim of this study was to investigate the column-specific degeneration in the cervical cord with CSM and explore the structure–function relationship by diffusion tensor imaging (DTI and functional magnetic resonance imaging (fMRI.Patients and methods: DTI and blood-oxygen-level-dependent (BOLD fMRI were obtained from 14 healthy controls and six patients with CSM at 3 T. The fractional anisotropy (FA value of anterior, lateral, and posterior column and the BOLD signal in response to somatosensory stimulation were compared among three groups: the average value of levels from C3 to C8 in the control and CSM groups and the value at maximal compression site in the CSM (CSM-mc group. The correlation between FA value and BOLD signal was used to assess the structure–function relationship.Results: The FA value in CSM-mc was lower than control-ave in all the columns (P<0.01 and lower than CSM-ave in the lateral and posterior column (P<0.05. The BOLD signal in CSM was significantly higher than that in the control (P<0.001. In the posterior column, a significant correlation between BOLD signal and FA value was found (P<0.05.Conclusion: This study demonstrated that the microstructural damage in CSM was correlated with functional changes. DTI combined with fMRI reveals the relationship between structural damage and neural activity, which might provide a promising method to

  13. Combined magnetic resonance and diffusion tensor imaging analyses provide a powerful tool for in vivo assessment of deformation along human muscle fibers.

    Science.gov (United States)

    Pamuk, Uluç; Karakuzu, Agah; Ozturk, Cengizhan; Acar, Burak; Yucesoy, Can A

    2016-10-01

    Muscle fiber direction strain provides invaluable information for characterizing muscle function. However, methods to study this for human muscles in vivo are lacking. Using magnetic resonance (MR) imaging based deformation analyses and diffusion tensor (DT) imaging based tractography combined, we aimed to assess muscle fiber direction local tissue deformations within the human medial gastrocnemius (GM) muscle. Healthy female subjects (n=5, age=27±1 years) were positioned prone within the MR scanner in a relaxed state with the ankle angle fixed at 90°. The knee was brought to flexion (140.8±3.0°) (undeformed state). Sets of 3D high resolution MR, and DT images were acquired. This protocol was repeated at extended knee joint position (177.0±1.0°) (deformed state). Tractography and Demons nonrigid registration algorithm was utilized to calculate local deformations along muscle fascicles. Undeformed state images were also transformed by a synthetic rigid body motion to calculate strain errors. Mean strain errors were significantly smaller then mean fiber direction strains (lengthening: 0.2±0.1% vs. 8.7±8.5%; shortening: 3.3±0.9% vs. 7.5±4.6%). Shortening and lengthening (up to 23.3% and 116.7%, respectively) occurs simultaneously along individual fascicles despite imposed GM lengthening. Along-fiber shear strains confirm the presence of much shearing between fascicles. Mean fiber direction strains of different tracts also show non-uniform distribution. Inhomogeneity of fiber strain indicates epimuscular myofascial force transmission. We conclude that MR and DT imaging analyses combined provide a powerful tool for quantifying deformation along human muscle fibers in vivo. This can help substantially achieving a better understanding of normal and pathological muscle function and mechanisms of treatment techniques. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. MRI (Magnetic Resonance Imaging)

    Science.gov (United States)

    ... and Procedures Medical Imaging MRI (Magnetic Resonance Imaging) MRI (Magnetic Resonance Imaging) Share Tweet Linkedin Pin it More sharing options ... usually given through an IV in the arm. MRI Research Programs at FDA Magnetic Resonance Imaging (MRI) ...

  15. Magnetic Resonance Imaging

    Science.gov (United States)

    ... specific information about your own examination. What is magnetic resonance imaging (MRI)? What is MRI used for? How safe ... What is the MRI examination like? What is magnetic resonance imaging (MRI)? MRI, or magnetic resonance imaging, is a ...

  16. Diffusion tensor cardiovascular magnetic resonance with a spiral trajectory: An in vivo comparison of echo planar and spiral stimulated echo sequences.

    Science.gov (United States)

    Gorodezky, Margarita; Scott, Andrew D; Ferreira, Pedro F; Nielles-Vallespin, Sonia; Pennell, Dudley J; Firmin, David N

    2017-12-19

    Diffusion tensor cardiovascular MR (DT-CMR) using stimulated echo acquisition mode (STEAM) with echo-planar-imaging (EPI) readouts is a low signal-to-noise-ratio (SNR) technique and therefore typically has a low spatial resolution. Spiral trajectories are more efficient than EPI, and could increase the SNR. The purpose of this study was to compare the performance of a novel STEAM spiral DT-CMR sequence with an equivalent established EPI technique. A STEAM DT-CMR sequence was implemented with a spiral readout and a reduced field of view. An in vivo comparison of DT-CMR parameters and data quality between EPI and spiral was performed in 11 healthy volunteers imaged in peak systole and diastasis at 3 T. The SNR was compared in a phantom and in vivo. There was a greater than 49% increase in the SNR in vivo and in the phantom measurements (in vivo septum, systole: SNR EPI  = 8.0 ± 2.2, SNR spiral  = 12.0 ± 2.7; diastasis: SNR EPI  = 8.1 ± 1.6, SNR spiral  = 12.0 ± 3.7). There were no significant differences in helix angle gradient (HAG) (systole: HAG EPI  = -0.79 ± 0.07 °/%; HAG spiral  = -0.74 ± 0.16 °/%; P = 0.11; diastasis: HAG EPI  = -0.63 ± 0.05 °/%; HAG spiral  = -0.56 ± 0.14 °/%; P = 0.20), mean diffusivity (MD) in systole (MD EPI  = 0.99 ± 0.06 × 10 -3 mm 2 /s, MD spiral  = 1.00 ± 0.09 × 10 -3 mm 2 /s, P = 0.23) and secondary eigenvector angulation (E2A) (systole: E2A EPI  = 61 ± 10 °; E2A spiral  = 63 ± 10 °; P = 0.77; diastasis: E2A EPI  = 18 ± 11 °; E2A spiral  = 15 ± 8 °; P = 0.20) between the sequences. There was a small difference (≈ 20%) in fractional anisotropy (FA) (systole: FA EPI  = 0.49 ± 0.03, FA spiral  = 0.41 ± 0.04; P parameters were largely similar between the two sequences. Magn Reson Med, 2017. © 2017 International Society for Magnetic Resonance in

  17. Evaluation of Diffusion Tensor Imaging-Based Tractography of the Corticospinal Tract: A Correlative Study With Intraoperative Magnetic Resonance Imaging and Direct Electrical Subcortical Stimulation.

    Science.gov (United States)

    Javadi, Seyed A; Nabavi, Arya; Giordano, Mario; Faghihzadeh, Elham; Samii, Amir

    2017-02-01

    The accuracy of intraoperative diffusion tensor imaging (DTI)–based tractography of the corticospinal tract (CST) is crucial for its use in neurosurgical planning and its implementation in image-guided surgery. To the best of our knowledge, this is the largest prospective correlative study of the intraoperative DTI tractography of the CST and intraoperative direct electrical subcortical stimulation (DESS) of the CST, with application of intraoperative magnetic resonance imaging (iMR). To evaluate intraoperatively acquired DTI-based tractography of the CST in correlation with DESS. Twenty patients with gliomas (grades II-IV) adjacent to the CST were included in this prospective study. Bilateral DTI tractography of the CST was performed pre- and intraoperatively with application of 1.5-T iMRI and the results correlated and compared with the prevailing gold standard of DESS. Sensitivity, specificity, positive predictive value, and negative predictive value were considered to quantify the correlation of DTI tractography with DESS. The intensity of DESS was correlated with the distance from the CST. Moreover, the tissue quality of stimulation points at the wall of the resection cavity was evaluated with 5-aminolevulinic acid. The clinical and volumetric outcomes at postoperative and follow-up periods were also analyzed. The mean ± SD age of the patients was 54.9 ± 12 years. A total of 40 CSTs were reconstructed and 36 stimulations were included at 20 pathological CSTs, resulting in 18 true-positive, 5 false-positive, and 13 true-negative responses. The sensitivity, specificity, positive predictive value, and negative predictive value of DTI tractography to localize the CST were 100%, 72%, 78%, and 100%, respectively. DTI-based tractography correlated well at 86% of DESSs, and a linear correlation was detected between the intensity of DESS and the distance. All of the patients improved clinically, and the mean extent of resection was 97.2%. 5-Aminolevulinic acid was

  18. 3D Inversion of SQUID Magnetic Tensor Data

    DEFF Research Database (Denmark)

    Zhdanov, Michael; Cai, Hongzhu; Wilson, Glenn

    2012-01-01

    Developments in SQUID-based technology have enabled direct measurement of magnetic tensor data for geophysical exploration. For quantitative interpretation, we introduce 3D regularized inversion for magnetic tensor data. For mineral exploration-scale targets, our model studies show that magnetic...... tensor data have significantly improved resolution compared to magnetic vector data for the same model. We present a case study for the 3D regularized inversion of magnetic tensor data acquired over a magnetite skarn at Tallawang, Australia. The results obtained from our 3D regularized inversion agree...

  19. Magnetic resonance angiography

    Science.gov (United States)

    MRA; Angiography - magnetic resonance ... Kwong RY. Cardiovascular magnetic resonance imaging. In: Bonow RO, Mann DL, Zipes DP, Libby P, Braunwald E, eds. Braunwald's Heart Disease: A Textbook of Cardiovascular ...

  20. Glioblastoma Presenting with Pure Alexia and Palinopsia Involving the Left Inferior Occipital Gyrus and Visual Word Form Area Evaluated with Functional Magnetic Resonance Imaging and Diffusion Tensor Imaging Tractography.

    Science.gov (United States)

    Huang, Meng; Baskin, David S; Fung, Steve

    2016-05-01

    Rapid word recognition and reading fluency is a specialized cortical process governed by the visual word form area (VWFA), which is localized to the dominant posterior lateral occipitotemporal sulcus/fusiform gyrus. A lesion of the VWFA results in pure alexia without agraphia characterized by letter-by-letter reading. Palinopsia is a visual processing distortion characterized by persistent afterimages and has been reported in lesions involving the nondominant occipitotemporal cortex. A 67-year-old right-handed woman with no neurologic history presented to our emergency department with acute cortical ischemic symptoms that began with a transient episode of receptive aphasia. She also reported inability to read, albeit with retained writing ability. She also saw afterimages of objects. During her stroke workup, an intra-axial circumscribed enhancing mass lesion was discovered involving her dominant posterolateral occipitotemporal lobe. Given the eloquent brain involvement, she underwent preoperative functional magnetic resonance imaging with diffusion tensor imaging tractography and awake craniotomy to maximize resection and preserve function. Many organic lesions involving these regions have been reported in the literature, but to the best of our knowledge, glioblastoma involving the VWFA resulting in both clinical syndromes of pure alexia and palinopsia with superimposed functional magnetic resonance imaging and fiber tract mapping has never been reported before. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. Magnetic Resonance Imaging (MRI) -- Head

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Magnetic Resonance Imaging (MRI) - Head Magnetic resonance imaging (MRI) of the head ... limitations of MRI of the Head? What is MRI of the Head? Magnetic resonance imaging (MRI) is ...

  2. Magnetic Resonance Imaging (MRI) - Spine

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Magnetic Resonance Imaging (MRI) - Spine Magnetic resonance imaging (MRI) of the spine ... limitations of MRI of the Spine? What is MRI of the Spine? Magnetic resonance imaging (MRI) is ...

  3. Magnetic Resonance Force Microscopy System

    Data.gov (United States)

    Federal Laboratory Consortium — The Magnetic Resonance Force Microscopy (MRFM) system, developed by ARL, is the world's most sensitive nuclear magnetic resonance (NMR) spectroscopic analysis tool,...

  4. Postoperative increase in cerebral white matter fractional anisotropy on diffusion tensor magnetic resonance imaging is associated with cognitive improvement after uncomplicated carotid endarterectomy: tract-based spatial statistics analysis.

    Science.gov (United States)

    Sato, Yuiko; Ito, Kenji; Ogasawara, Kuniaki; Sasaki, Makoto; Kudo, Kohsuke; Murakami, Toshiyuki; Nanba, Takamasa; Nishimoto, Hideaki; Yoshida, Kenji; Kobayashi, Masakazu; Kubo, Yoshitaka; Mase, Tomohiko; Ogawa, Akira

    2013-10-01

    Carotid endarterectomy (CEA) might improve cognitive function. Fractional anisotropy (FA) values in the cerebral white matter derived from diffusion tensor magnetic resonance imaging (DTI) correlate with cognitive function in patients with various central nervous system diseases. To use tract-based spatial statistics to determine whether postoperative changes of FA values in the cerebral white matter derived from DTI are associated with cognitive improvement after uncomplicated CEA. In 80 patients undergoing CEA for ipsilateral internal carotid artery stenosis (≥70%), FA values in the cerebral white matter were derived from DTI before and 1 month after surgery and were analyzed by using tract-based spatial statistics. Neuropsychological testing, consisting of the Wechsler Adult Intelligence Scale Revised, the Wechsler Memory Scale and the Rey-Osterreith Complex Figure test, was also performed preoperatively and after the first postoperative month. Based on the neuropsychological assessments, 11 (14%) patients were defined as having postoperatively improved cognition. The difference between the 2 mean FA values (postoperative values minus preoperative values) in the cerebral hemisphere ipsilateral to surgery was significantly associated with postoperative cognitive improvement (95% confidence intervals, 2.632-9.877; P = .008). White matter FA values in patients with postoperative cognitive improvement were significantly increased after surgery in the whole ipsilateral cerebral hemisphere, in the contralateral anterior cerebral artery territory, and in the watershed zone between the contralateral anterior and middle cerebral arteries. Postoperative increase in cerebral white matter FA on DTI is associated with cognitive improvement after uncomplicated CEA.

  5. 3D inversion of full tensor magnetic gradiometry (FTMG) data

    DEFF Research Database (Denmark)

    Zhdanov, Michael; Cai, Hongzhu; Wilson, Glenn

    2011-01-01

    Following recent advances in SQUID technology, full tensor magnetic gradiometry (FTMG) is emerging as a practical exploration method. We introduce 3D regularized focusing inversion for FTMG data. Our model studies show that inversion of magnetic tensor data can significantly improve resolution...... compared to inversion of magnetic vector data for the same model. We present a case study for the 3D inversion of GETMAG® FTMG data acquired over a magnetite skarn at Tallawang, Australia. The results obtained from our 3D inversion agree very well with the known geology of the area....

  6. Magnetic Resonance Sensors

    Directory of Open Access Journals (Sweden)

    Robert H. Morris

    2014-11-01

    Full Text Available Magnetic Resonance finds countless applications, from spectroscopy to imaging, routinely in almost all research and medical institutions across the globe. It is also becoming more frequently used for specific applications in which the whole instrument and system is designed for a dedicated application. With beginnings in borehole logging for the petro-chemical industry Magnetic Resonance sensors have been applied to fields as varied as online process monitoring for food manufacture and medical point of care diagnostics. This great diversity is seeing exciting developments in magnetic resonance sensing technology published in application specific journals where they are often not seen by the wider sensor community. It is clear that there is enormous interest in magnetic resonance sensors which represents a significant growth area. The aim of this special edition of Sensors was to address the wide distribution of relevant articles by providing a forum to disseminate cutting edge research in this field in a single open source publication.[...

  7. Ghost magnetic resonance angiography

    National Research Council Canada - National Science Library

    Koktzoglou, Ioannis; Edelman, Robert R

    2009-01-01

    Traditional methods for magnetic resonance angiography (MRA) involve the radiofrequency excitation of vascular spins within a selected region of tissue, followed by gradient localization and imaging of those spins within that same region...

  8. Diffusion tensor magnetic resonance imaging may show abnormalities in the normal-appearing cervical spinal cord from patients with multiple sclerosis

    Directory of Open Access Journals (Sweden)

    Fernanda Miraldi

    2013-09-01

    Full Text Available Objective This study aims to evaluate “in vivo” the integrity of the normal-appearing spinal cord (NASC in patients with multiple sclerosis (MS compared to controls, using diffusion tensor MR imaging. Methods We studied 32 patients with MS and 17 without any neurologic disorder. Fractional anisotropy (FA, axial diffusivity (AD, radial diffusivity (RD and mean diffusivity (MD were calculated within regions of interest at C2 and C7 levels in the four columns of the spinal cord. Results At C2, FA value was decreased in MS patients. Besides, RD value was higher in MS than in controls. At C7, MD values were increased in MS. Conclusion The NASC in the right column of the cervical spinal cord showed abnormal FA, RD and MD values, which is possibly related to demyelination, since the FA abnormality was related to the RD and not to the AD.

  9. Magnetic Resonance Sensors

    OpenAIRE

    Morris, RH; Newton, MI

    2014-01-01

    Magnetic Resonance finds countless applications, from spectroscopy to imaging, routinely in almost all research and medical institutions across the globe. It is also becoming more frequently used for specific applications in which the whole instrument and system is designed for a dedicated application. With beginnings in borehole logging for the petro-chemical industry Magnetic Resonance sensors have been applied to fields as varied as online process monitoring for food manufacture and medica...

  10. Nuclear Magnetic Resonance Spectroscopy

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 9; Issue 1. Nuclear Magnetic Resonance Spectroscopy. Susanta Das. General Article Volume 9 Issue 1 January 2004 pp 34-49. Fulltext. Click here to view fulltext PDF. Permanent link: http://www.ias.ac.in/article/fulltext/reso/009/01/0034-0049. Keywords.

  11. Evaluation of white matter integrity in systemic lupus erythematosus by diffusion tensor magnetic resonance imaging: a study using tract-based spatial statistics

    Energy Technology Data Exchange (ETDEWEB)

    Goulart Correa, Diogo; Ventura, Nina; Gasparetto, Emerson Leandro [Federal University of Rio de Janeiro, Department of Radiology, Hospital Universitario Clementino Fraga Filho, Rio de Janeiro, RJ (Brazil); Clinica de Diagnostico por Imagem (CDPI), Rio de Janeiro, RJ (Brazil); Zimmermann, Nicolle; Paz Fonseca, Rochele [Federal University of Rio de Janeiro, Department of Radiology, Hospital Universitario Clementino Fraga Filho, Rio de Janeiro, RJ (Brazil); Pontifical Catholic University of Rio Grande do Sul, Department of Psychology, Porto Alegre, RS (Brazil); Batista Pereira, Denis; Netto, Tania Maria [Federal University of Rio de Janeiro, Department of Radiology, Hospital Universitario Clementino Fraga Filho, Rio de Janeiro, RJ (Brazil); Doring, Thomas M. [Clinica de Diagnostico por Imagem (CDPI), Rio de Janeiro, RJ (Brazil)

    2016-08-15

    The aim of this study was to evaluate the white matter integrity in brains of patients with systemic lupus erythematosus (SLE) using a voxel-based analyses of diffusion tensor imaging (DTI) data. Fifty-seven patients with SLE were compared to 36 control patients who were matched by gender, age, education, and Mini Mental State Examination score. DTI was performed along 30 noncollinear directions in a 1.5 Tesla scanner. For tract-based spatial statistics (TBSS), a white matter skeleton was created, and a permutation-based inference with 5000 permutations and a threshold of p < 0.05 was used to identify abnormalities in fractional anisotropy (FA). The mean (MD), radial (RD), and axial diffusivities (AD) were also projected onto the mean FA skeleton. We found a significant decrease of global FA in SLE patients compared to controls. The areas of reduced FA included the right superior corona radiata, the right superior longitudinal fasciculus, the body of the corpus callosum, the right inferior fronto-occipital fasciculus, the right thalamic radiation, and the right uncinate fasciculus. Patients with SLE also had increased AD and RD in several areas. Substantial overlap of areas with increased AD and RD occurred and were spatially much more extensive than the areas of reduced FA. Significant increases of AD values were concordant to those of RD and MD and more extensive than FA changes. Analyzing all diffusivity parameters, using TBSS, can detect more white matter microstructural changes in patients with SLE than analyzing FA alone. (orig.)

  12. Functional and white matter abnormalities in the language network in patients with schizophrenia: a combined study with diffusion tensor imaging and functional magnetic resonance imaging.

    Science.gov (United States)

    Leroux, Elise; Delcroix, Nicolas; Alary, Mathieu; Razafimandimby, Annick; Brazo, Perrine; Delamillieure, Pascal; Dollfus, Sonia

    2013-10-01

    Schizophrenia is a mental disorder characterized by functional abnormalities in the language network. Anatomical white matter (WM) abnormalities (volume and integrity) have also been reported for this pathology. Nevertheless, few studies have investigated anatomo-functional relationships in schizophrenia, and none has focused on the language comprehension network in relation to various diffusion parameters. We hypothesized that the WM abnormalities that are reflected by several diffusion parameters underlie functional deficits in the language network. Eighteen DSM-IV patients with schizophrenia and 18 healthy controls without any significant differences in sex, age, or level of education were included. First, functional brain activation within the language network was estimated. Then, using diffusion tensor imaging, fractional anisotropy (FA), radial diffusivity (RD), and mean diffusivity (MD) values were extracted within WM regions adjacent to this network and their anatomo-functional relationships were investigated. Compared with healthy participants, both functional and diffusion deficits were observed in patients with schizophrenia. Primarily, an altered diffusion-functional relationship was observed in patients in the left middle temporal region: functional activations were positively correlated with FA, but were negatively correlated with RD. Our findings indicate a close relationship between diffusion and functional deficits in patients with schizophrenia, suggesting that WM integrity disturbance might be one cause of functional alterations in the language network in patients with schizophrenia. Thus, the present multimodal study improves our understanding of the pathophysiology of schizophrenia. © 2013 Elsevier B.V. All rights reserved.

  13. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... Resources Professions Site Index A-Z Children’s (Pediatric) Magnetic Resonance Imaging Children’s magnetic resonance imaging (MRI) uses a powerful magnetic field, radio waves ...

  14. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Magnetic Resonance Imaging (MRI) - Head Magnetic resonance imaging (MRI) of the head uses a powerful magnetic field, radio waves and a computer to produce ...

  15. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... Resources Professions Site Index A-Z Children’s (Pediatric) Magnetic Resonance Imaging Children’s magnetic resonance imaging (MRI) uses a powerful magnetic field, radio ...

  16. Accelerated magnetic resonance diffusion tensor imaging of the median nerve using simultaneous multi-slice echo planar imaging with blipped CAIPIRINHA

    Energy Technology Data Exchange (ETDEWEB)

    Filli, Lukas; Kenkel, David; Boss, Andreas; Manoliu, Andrei; Andreisek, Gustav; Runge, Val M.; Guggenberger, Roman [University Hospital of Zurich, University of Zurich, Institute of Diagnostic and Interventional Radiology, Zurich (Switzerland); Piccirelli, Marco [University Hospital of Zurich, Department of Neuroradiology, Zurich (Switzerland); Bhat, Himanshu [Siemens Medical Solutions USA Inc, Charlestown, MA (United States)

    2016-06-15

    To investigate the feasibility of MR diffusion tensor imaging (DTI) of the median nerve using simultaneous multi-slice echo planar imaging (EPI) with blipped CAIPIRINHA. After federal ethics board approval, MR imaging of the median nerves of eight healthy volunteers (mean age, 29.4 years; range, 25-32) was performed at 3 T using a 16-channel hand/wrist coil. An EPI sequence (b-value, 1,000 s/mm{sup 2}; 20 gradient directions) was acquired without acceleration as well as with twofold and threefold slice acceleration. Fractional anisotropy (FA), mean diffusivity (MD) and quality of nerve tractography (number of tracks, average track length, track homogeneity, anatomical accuracy) were compared between the acquisitions using multivariate ANOVA and the Kruskal-Wallis test. Acquisition time was 6:08 min for standard DTI, 3:38 min for twofold and 2:31 min for threefold acceleration. No differences were found regarding FA (standard DTI: 0.620 ± 0.058; twofold acceleration: 0.642 ± 0.058; threefold acceleration: 0.644 ± 0.061; p ≥ 0.217) and MD (standard DTI: 1.076 ± 0.080 mm{sup 2}/s; twofold acceleration: 1.016 ± 0.123 mm{sup 2}/s; threefold acceleration: 0.979 ± 0.153 mm{sup 2}/s; p ≥ 0.074). Twofold acceleration yielded similar tractography quality compared to standard DTI (p > 0.05). With threefold acceleration, however, average track length and track homogeneity decreased (p = 0.004-0.021). Accelerated DTI of the median nerve is feasible. Twofold acceleration yields similar results to standard DTI. (orig.)

  17. Multimodal imaging in diagnosis of Alzheimer's disease and amnestic mild cognitive impairment: value of magnetic resonance spectroscopy, perfusion, and diffusion tensor imaging of the posterior cingulate region.

    Science.gov (United States)

    Zimny, Anna; Szewczyk, Pawel; Trypka, Elzbieta; Wojtynska, Renata; Noga, Leszek; Leszek, Jerzy; Sasiadek, Marek

    2011-01-01

    The purpose of this study was to assess metabolic, perfusion, and microstructural changes within the posterior cingulate area in patients with Alzheimer's disease (AD) and amnestic mild cognitive impairment (aMCI) using advanced MR techniques such as: spectroscopy (MRS), perfusion weighted imaging (PWI), and diffusion tensor imaging (DTI). Thirty patients with AD (mean age 71.5 y, MMSE 18), 23 with aMCI (mean age 66 y, MMSE 27.4), and 15 age-matched normal controls (mean age 69 y, MMSE 29.5) underwent conventional MRI followed by MRS, PWI, and DTI on 1.5 Tesla MR unit. Several metabolite ratios (N-acetylaspartate [NAA]/creatine [Cr], choline [Ch]/Cr, myoinositol [mI]/Cr, mI/NAA, mI/Cho) as well as parameters of cerebral blood volume relative to cerebellum and fractional anisotropy were obtained in the posterior cingulate region. The above parameters were correlated with the results of neuropsychological tests. AD patients showed significant abnormalities in all evaluated parameters while subjects with aMCI showed only perfusion and diffusion changes in the posterior cingulate area. Only PWI and DTI measurements revealed significant differences among the three evaluated subject groups. DTI, PWI, and MRS results showed significant correlations with neuropsychological tests. DTI changes correlated with both PWI and MRS abnormalities. Of neuroimaging methods, DTI revealed the highest accuracy in diagnosis of AD and aMCI (0.95, 0.79) followed by PWI (0.87, 0.67) and MRS (0.82, 0.47), respectively. In conclusion, AD is a complex pathology regarding both grey and white matter. DTI seems to be the most useful imaging modality to distinguish between AD, aMCI, and control group, followed by PWI and MRS.

  18. Quantification of Corticospinal Tracts with Diffusion Tensor Imaging in Brainstem Surgery: Prognostic Value in 14 Consecutive Cases at 3T Magnetic Resonance Imaging.

    Science.gov (United States)

    Yao, Yuqiang; Ulrich, Nils H; Guggenberger, Roman; Alzarhani, Yahea A; Bertalanffy, Helmut; Kollias, Spyros S

    2015-06-01

    In this study, we investigated the potential prognostic role of morphologic and quantitative diffusion tensor imaging (DTI) in patients with brainstem cavernoma (BSC) in terms of postoperative outcome. In this retrospective study of 14 brainstem cavernoma patients, we analyzed pre- and postoperative DTI data. White matter tractography of corticospinal tracts (CSTs) was performed with the Fiber Assignment by Continuous Tracking algorithm, and morphologic characteristics of CSTs were compared with clinically assessed motor strength. Fractional anisotropy (FA) and apparent diffusion coefficient (ADC) were measured in ipsi- and contralesional regions of interest at the lesion level, as well as levels caudal and rostral to the lesion. Correlation analysis was performed between lateral index (LI) of ipsi-/contralateral FA and ADC values and patients' motor function. Preoperatively, normal morphologic features of CSTs corresponded to normal motor function in 4 patients. The other 10 morphologically abnormal preoperative CSTs didn't show corresponding motor impairment either in pre- or postoperative follow-up period. The sensitivity, specificity, positive predictive, and negative predictive values of white matter tractographic morphology on preoperative motor function were 100%, 57.1%, 70%, and 100%, respectively. The corresponding values on follow-up motor function were 100%, 33.3%, 20%, and 100%, respectively. The mean FA at lesion level was significantly lower than the corresponding FA at the contralateral hemisphere (P = 0.009). In areas caudal to the lesion the same trend yet without statistic significance was observed (P = 0.23). There was no significant laterality difference of mean FAs rostral to the level of the lesion. No correlation in LI of FA or ADC in the 3 anatomic levels with simultaneous and long-term follow up motor function was observed. Restoration of the morphology of the affected CST postoperatively was associated with a trend for decreasing ADC

  19. Magnetic Resonance Safety

    OpenAIRE

    Sammet, Steffen

    2016-01-01

    Magnetic Resonance Imaging (MRI) has a superior soft-tissue contrast compared to other radiological imaging modalities and its physiological and functional applications have led to a significant increase in MRI scans worldwide. A comprehensive MRI safety training to protect patients and other healthcare workers from potential bio-effects and risks of the magnetic fields in an MRI suite is therefore essential. The knowledge of the purpose of safety zones in an MRI suite as well as MRI appropri...

  20. Nuclear Magnetic Resonance

    Indian Academy of Sciences (India)

    IAS Admin

    This article summarizes the early history of nuclear magnetic resonance (NMR) during the first 25–30 years. The method- ology went through vigorous growth and development during this time, laying the theoretical basis for understanding a wide array of applications. The stage was set for the breath- taking advances the ...

  1. Functional Magnetic Resonance Imaging

    Science.gov (United States)

    Voos, Avery; Pelphrey, Kevin

    2013-01-01

    Functional magnetic resonance imaging (fMRI), with its excellent spatial resolution and ability to visualize networks of neuroanatomical structures involved in complex information processing, has become the dominant technique for the study of brain function and its development. The accessibility of in-vivo pediatric brain-imaging techniques…

  2. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... information on the chemicals present in the body's cells, may also be performed during the MRI exam ... and Media Catheter Angiography Magnetic Resonance, Functional (fMRI) - Brain Children's (Pediatric) CT (Computed Tomography) Magnetic Resonance Imaging ( ...

  3. Magnetic Resonance Imaging (MRI) Safety

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Magnetic Resonance Imaging (MRI) Safety What is MRI and how does it ... and MRI Breast-feeding and MRI What is MRI and how does it work? Magnetic resonance imaging, ...

  4. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... content. Related Articles and Media MR Angiography (MRA) Magnetic Resonance, Functional (fMRI) - Brain Head and Neck Cancer Treatment Brain Tumor Treatment Magnetic Resonance Imaging (MRI) Safety Alzheimer's Disease Head Injury Brain ...

  5. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... the same effect. A very irregular heartbeat may affect the quality of images obtained using techniques that ... and Media Catheter Angiography Magnetic Resonance, Functional (fMRI) - Brain Children's (Pediatric) CT (Computed Tomography) Magnetic Resonance Imaging ( ...

  6. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... Articles and Media MR Angiography (MRA) Magnetic Resonance, Functional (fMRI) - Brain Head and Neck Cancer Treatment Brain Tumor Treatment Magnetic Resonance Imaging (MRI) Safety Alzheimer's Disease Head Injury Brain Tumors Images related to ...

  7. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... data suggest that it is safe to continue breastfeeding after receiving intravenous contrast. For further information please ... Magnetic Resonance Imaging (MRI) Safety Alzheimer's Disease Head Injury Brain Tumors Images related to Magnetic Resonance Imaging ( ...

  8. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... for Brain Tumors Radiation Therapy for Head and Neck Cancer Others : American Stroke Association National Stroke Association ... MRA) Magnetic Resonance, Functional (fMRI) - Brain Head and Neck Cancer Treatment Brain Tumor Treatment Magnetic Resonance Imaging ( ...

  9. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... may sense a temporary metallic taste in their mouth after the contrast injection. If you do not ... Magnetic Resonance Imaging (MRI) Safety Alzheimer's Disease Head Injury Brain Tumors Images related to Magnetic Resonance Imaging ( ...

  10. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Magnetic Resonance Imaging (MRI) - Head Magnetic resonance imaging (MRI) of the head ... limitations of MRI of the Head? What is MRI of the Head? Magnetic resonance imaging (MRI) is ...

  11. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... Resources Professions Site Index A-Z Children’s (Pediatric) Magnetic Resonance Imaging Children’s magnetic resonance imaging (MRI) uses a powerful ... of Children’s (Pediatric) MRI? What is Children’s (Pediatric) MRI? Magnetic resonance imaging (MRI) is a noninvasive medical ...

  12. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Children’s (Pediatric) Magnetic Resonance Imaging Children’s magnetic resonance imaging ( ... the limitations of Children’s (Pediatric) MRI? What is Children’s (Pediatric) MRI? Magnetic resonance imaging (MRI) is a ...

  13. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Magnetic Resonance Imaging (MRI) - Head Magnetic resonance imaging (MRI) of the head uses a powerful ... Head? What is MRI of the Head? Magnetic resonance imaging (MRI) is a noninvasive medical test that ...

  14. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Children’s (Pediatric) Magnetic Resonance Imaging Children’s magnetic resonance imaging (MRI) ... limitations of Children’s (Pediatric) MRI? What is Children’s (Pediatric) MRI? Magnetic resonance imaging (MRI) is a noninvasive ...

  15. Calibration of magnetic gradient tensor measurement array in magnetic anomaly detection

    Science.gov (United States)

    Chen, Jinfei; Zhang, Qi; Pan, Mengchun; Weng, Feibing; Chen, Dixiang; Pang, Hongfeng

    2013-01-01

    Magnetic anomaly detection based on magnetic gradient tensor has become more and more important in civil and military applications. Compared with methods based on magnetic total field or components measurement, magnetic gradient tensor has some unique advantages. Usually, a magnetic gradient tensor measurement array is constituted by four three-axis magnetometers. The prominent problem of magnetic gradient tensor measurement array is the misalignment of sensors. In order to measure the magnetic gradient tensor accurately, it is quite essential to calibrate the measurement array. The calibration method, which is proposed in this paper, is divided into two steps. In the first step, each sensor of the measurement array should be calibrated, whose error is mainly caused by constant biases, scale factor deviations and nonorthogonality of sensor axes. The error of measurement array is mainly caused by the misalignment of sensors, so that triplets' deviation in sensors array coordinates is calibrated in the second step. In order to verify the effectiveness of the proposed method, simulation was taken and the result shows that the proposed method improves the measurement accuracy of magnetic gradient tensor greatly.

  16. Molecular Cardiovascular Magnetic Resonance

    DEFF Research Database (Denmark)

    Bender, Yvonne Y; Pfeifer, Andreas; Ebersberger, Hans U

    2016-01-01

    In the Western world and developing countries, the number one causes of mortality and morbidity result from cardiovascular diseases. Cardiovascular diseases represent a wide range of pathologies, including myocardial infarction, peripheral vascular disease, and cerebrovascular disease, which...... impact on society, there are still limitations in the early diagnosis and the prevention of the disease. Current imaging methods mainly focus on morphological changes that occur at an advanced disease stage, e.g., degree of stenosis. Cardiovascular magnetic resonance imaging and specifically molecular...... cardiovascular magnetic resonance imaging are capable to reveal pathophysiological changes already occurring during early atherosclerotic plaque formation. This allows for the assessment of cardiovascular disease on a level, which goes beyond morphological or anatomical criteria. In this review, we...

  17. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... magnetic resonance imaging (MRI) uses a powerful magnetic field, radio waves and a computer to produce detailed ... problems, medications, recent surgeries and allergies. The magnetic field is not harmful, but it may cause some ...

  18. [Nuclear magnetic resonance tomography].

    Science.gov (United States)

    Ganssen, A; Loeffler, W; Oppelt, A; Schmidt, F

    1981-04-01

    Imaging methods based on nuclear magnetic resonance allow the production of sectional images of the human body without ionizing radiation. It is possible to measure the density and relaxation times of the water protons in body fluids or tissue. This allows not only to obtain morphological information but also to get some insight into the spatial distribution of physiological data. Starting with a review of the principles of nuclear magnetic resonance it is explained how the measured signal can be associated with an image point; it is also explained what type of apparatus is necessary and what the physical limitations are. Possible risks the patient may be exposed to in an examination using nuclear magnetic resonance are discussed. The present state of the technical development enables the production of whole-body sectional images of a living person within about one minute. By means of some typical examples the nature and properties of these images are explained. Although extensive clinical studies will be necessary before a more general assessment can be made of this method, an outlook is provided on expected further developments and possible future fields of application.

  19. Magnetic resonance imaging of the fetal brain.

    Science.gov (United States)

    Tee, L Mf; Kan, E Yl; Cheung, J Cy; Leung, W C

    2016-06-01

    This review covers the recent literature on fetal brain magnetic resonance imaging, with emphasis on techniques, advances, common indications, and safety. We conducted a search of MEDLINE for articles published after 2010. The search terms used were "(fetal OR foetal OR fetus OR foetus) AND (MR OR MRI OR [magnetic resonance]) AND (brain OR cerebral)". Consensus statements from major authorities were also included. As a result, 44 relevant articles were included and formed the basis of this review. One major challenge is fetal motion that is largely overcome by ultra-fast sequences. Currently, single-shot fast spin-echo T2-weighted imaging remains the mainstay for motion resistance and anatomical delineation. Recently, a snap-shot inversion recovery sequence has enabled robust T1-weighted images to be obtained, which is previously a challenge for standard gradient-echo acquisitions. Fetal diffusion-weighted imaging, diffusion tensor imaging, and magnetic resonance spectroscopy are also being developed. With multiplanar capabilities, superior contrast resolution and field of view, magnetic resonance imaging does not have the limitations of sonography, and can provide additional important information. Common indications include ventriculomegaly, callosum and posterior fossa abnormalities, and twin complications. There are safety concerns about magnetic resonance-induced heating and acoustic damage but current literature showed no conclusive evidence of deleterious fetal effects. The American College of Radiology guideline states that pregnant patients can be accepted to undergo magnetic resonance imaging at any stage of pregnancy if risk-benefit ratio to patients warrants that the study be performed. Magnetic resonance imaging of the fetal brain is a safe and powerful adjunct to sonography in prenatal diagnosis. It can provide additional information that aids clinical management, prognostication, and counselling.

  20. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... techniques that time the imaging based on the electrical activity of the heart, such as electrocardiography (ECG). ... Resonance, Functional (fMRI) - Brain Children's (Pediatric) CT (Computed Tomography) Magnetic Resonance Imaging (MRI) Safety Contrast Materials Children ...

  1. Cardiovascular Magnetic Resonance Imaging

    Science.gov (United States)

    Pelc, Norbert

    2000-03-01

    Cardiovascular diseases are a major source of morbidity and mortality in the United States. Early detection of disease can often be used to improved outcomes, either through direct interventions (e.g. surgical corrections) or by causing the patient to modify his or her behavior (e.g. smoking cessation or dietary changes). Ideally, the detection process should be noninvasive (i.e. it should not be associated with significant risk). Magnetic Resonance Imaging (MRI) refers to the formation of images by localizing NMR signals, typically from protons in the body. As in other applications of NMR, a homogeneous static magnetic field ( ~0.5 to 4 T) is used to create ``longitudinal" magnetization. A magnetic field rotating at the Larmor frequency (proportional to the static field) excites spins, converting longitudinal magnetization to ``transverse" magnetization and generating a signal. Localization is performed using pulsed gradients in the static field. MRI can produce images of 2-D slices, 3-D volumes, time-resolved images of pseudo-periodic phenomena such as heart function, and even real-time imaging. It is also possible to acquire spatially localized NMR spectra. MRI has a number of advantages, but perhaps the most fundamental is the richness of the contrast mechanisms. Tissues can be differentiated by differences in proton density, NMR properties, and even flow or motion. We also have the ability to introduce substances that alter NMR signals. These contrast agents can be used to enhance vascular structures and measure perfusion. Cardiovascular MRI allows the reliable diagnosis of important conditions. It is possible to image the blood vessel tree, quantitate flow and perfusion, and image cardiac contraction. Fundamentally, the power of MRI as a diagnostic tool stems from the richness of the contrast mechanisms and the flexibility in control of imaging parameters.

  2. Advances in magnetic resonance 11

    CERN Document Server

    Waugh, John S

    2013-01-01

    Advances in Magnetic Resonance, Volume 11, presents a variety of contributions to the theory and practice of magnetic resonance. The book contains three chapters and begins with a discussion of the principles and applications of dynamic nuclear polarization, with emphasis on molecular motions and collisions, intermolecular couplings, and chemical interactions. Subsequent chapters focus on the assessment of a proposed broadband decoupling method and studies of time-domain (or Fourier transform) multiple-quantum nuclear magnetic resonance.

  3. Advances in magnetic resonance 6

    CERN Document Server

    Waugh, John S

    2013-01-01

    Advances in Magnetic Resonance, Volume 6 focuses on the theoretical and practical aspects of applying magnetic resonance methods to various problems in physical chemistry, emphasizing the different aspects of the exegesis of these problems. This book discusses the gas phase magnetic resonance of electronically excited molecules; techniques for observing excited electronic states; NMR studies in liquids at high pressure; and effect of pressure on self-diffusion in liquids. The nuclear magnetic resonance investigations of organic free radicals; measurement of proton coupling constants by NMR; an

  4. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... an IV line, into a vein in your hand or arm. A saline solution may be used ... Tumor Treatment Magnetic Resonance Imaging (MRI) Safety Alzheimer's Disease Head Injury Brain Tumors Images related to Magnetic ...

  5. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... Videos About Us News Physician Resources Professions Site Index A-Z Magnetic Resonance Imaging (MRI) - Head Magnetic ... very early stage by mapping the motion of water molecules in the tissue. This water motion, known ...

  6. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... the same effect. A very irregular heartbeat may affect the quality of images obtained using techniques that ... Tumor Treatment Magnetic Resonance Imaging (MRI) Safety Alzheimer's Disease Head Injury Brain Tumors Images related to Magnetic ...

  7. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... a CD or uploaded to a digital cloud server. Currently, MRI is the most sensitive imaging test ... Brain Tumor Treatment Magnetic Resonance Imaging (MRI) Safety Alzheimer's Disease Head Injury Brain Tumors Images related to Magnetic ...

  8. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... copied to a CD or uploaded to a digital cloud server. Currently, MRI is the most sensitive ... Brain Tumor Treatment Magnetic Resonance Imaging (MRI) Safety Alzheimer's Disease Head Injury Brain Tumors Images related to Magnetic ...

  9. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... resonance imaging (MRI) uses a powerful magnetic field, radio waves and a computer to produce detailed pictures ... medical conditions. MRI uses a powerful magnetic field, radio frequency pulses and a computer to produce detailed ...

  10. Partially orthogonal resonators for magnetic resonance imaging

    Science.gov (United States)

    Chacon-Caldera, Jorge; Malzacher, Matthias; Schad, Lothar R.

    2017-02-01

    Resonators for signal reception in magnetic resonance are traditionally planar to restrict coil material and avoid coil losses. Here, we present a novel concept to model resonators partially in a plane with maximum sensitivity to the magnetic resonance signal and partially in an orthogonal plane with reduced signal sensitivity. Thus, properties of individual elements in coil arrays can be modified to optimize physical planar space and increase the sensitivity of the overall array. A particular case of the concept is implemented to decrease H-field destructive interferences in planar concentric in-phase arrays. An increase in signal to noise ratio of approximately 20% was achieved with two resonators placed over approximately the same planar area compared to common approaches at a target depth of 10 cm at 3 Tesla. Improved parallel imaging performance of this configuration is also demonstrated. The concept can be further used to increase coil density.

  11. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... MRI scanners are air-conditioned and well-lit. Music may be played through the headphones to help ... and Media Catheter Angiography Magnetic Resonance, Functional (fMRI) - Brain Children's (Pediatric) CT (Computed Tomography) Magnetic Resonance Imaging ( ...

  12. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... have special pediatric considerations. The teddy bear denotes child-specific content. Related Articles and Media MR Angiography (MRA) Magnetic Resonance, Functional (fMRI) - Brain Head and Neck Cancer Treatment Brain Tumor Treatment Magnetic Resonance Imaging (MRI) ...

  13. Advances in magnetic resonance 12

    CERN Document Server

    Waugh, John S

    2013-01-01

    Advances in Magnetic Resonance, Volume 12, presents a variety of contributions to the theory and practice of magnetic resonance. The book contains six chapters and begins with a discussion of diffusion and self-diffusion measurements by nuclear magnetic resonance. This is followed by separate chapters on spin-lattice relaxation time in hydrogen isotope mixtures; the principles of optical detection of nuclear spin alignment and nuclear quadropole resonance; and the spin-1 behavior, including the relaxation of the quasi-invariants of the motion of a system of pairs of dipolar coupled spin-1/2 nu

  14. Low field magnetic resonance imaging

    Science.gov (United States)

    Pines, Alexander; Sakellariou, Dimitrios; Meriles, Carlos A.; Trabesinger, Andreas H.

    2010-07-13

    A method and system of magnetic resonance imaging does not need a large homogenous field to truncate a gradient field. Spatial information is encoded into the spin magnetization by allowing the magnetization to evolve in a non-truncated gradient field and inducing a set of 180 degree rotations prior to signal acquisition.

  15. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... Children’s magnetic resonance imaging (MRI) uses a powerful magnetic field, radio waves and a computer to produce detailed ... health problems, medications, recent surgeries and allergies. The magnetic field is not harmful, but it may cause some ...

  16. Dynamic magnetic susceptibility and electrical detection of ferromagnetic resonance

    Science.gov (United States)

    Zhang, Yin; Wang, X. S.; Yuan, H. Y.; Kang, S. S.; Zhang, H. W.; Wang, X. R.

    2017-03-01

    The dynamic magnetic susceptibility of magnetic materials near ferromagnetic resonance (FMR) is very important in interpreting the dc voltage obtained in its electrical detection. Based on the causality principle and the assumption that the usual microwave absorption lineshape of a homogeneous magnetic material around FMR is Lorentzian, the general forms of the dynamic magnetic susceptibility of an arbitrary sample and the corresponding dc voltage lineshapes of its electrical detection were obtained. Our main findings are as follows. (1) The dynamic magnetic susceptibility is not a Polder tensor for a material with an arbitrary magnetic anisotropy. The two off-diagonal matrix elements of the tensor near FMR are not, in general, opposite to each other. However, the linear response coefficient of the magnetization to the total radio frequency (rf) field (the sum of the external and internal rf fields due to precessing magnetization is a quantity which cannot be measured directly) is a Polder tensor. This may explain why the two off-diagonal susceptibility matrix elements were always wrongly assumed to be opposite to each other in almost all analyses. (2) The frequency dependence of dynamic magnetic susceptibility near FMR is fully characterized by six real numbers, while its field dependence is fully characterized by seven real numbers. (3) A recipe of how to determine these numbers by standard microwave absorption measurements for a sample with an arbitrary magnetic anisotropy is proposed. Our results allow one to unambiguously separate the contribution of the anisotropic magnetoresistance to the dc voltage signals from the anomalous Hall effect. With these results, one can reliably extract the information of spin pumping and the inverse spin-Hall effect, and determine the spin-Hall angle. (4) In the case that resonance frequency is not sensitive to the applied static magnetic field, the field dependence of the matrix elements of dynamic magnetic susceptibility, as

  17. Advances in magnetic resonance 1

    CERN Document Server

    Waugh, John S

    2013-01-01

    Advances in Magnetic Resonance, Volume 1, discusses developments in various areas of magnetic resonance. The subject matter ranges from original theoretical contributions through syntheses of points of view toward series of phenomena to critical and painstaking tabulations of experimental data. The book contains six chapters and begins with a discussion of the theory of relaxation processes. This is followed by separate chapters on the development of magnetic resonance techniques for studying rate processes in chemistry and the application of these techniques to various problems; the geometri

  18. Advances in magnetic resonance 9

    CERN Document Server

    Waugh, John S

    2013-01-01

    Advances in Magnetic Resonance, Volume 9 describes the magnetic resonance in split constants and dipolar relaxation. This book discusses the temperature-dependent splitting constants in the ESR spectra of organic free radicals; temperature-dependent splittings in ion pairs; and magnetic resonance induced by electrons. The electron impact excitation of atoms and molecules; intramolecular dipolar relaxation in multi-spin systems; and dipolar cross-correlation problem are also elaborated. This text likewise covers the NMR studies of molecules oriented in thermotropic liquid crystals and diffusion

  19. Nuclear magnetic resonance contrast agents

    Science.gov (United States)

    Smith, P.H.; Brainard, J.R.; Jarvinen, G.D.; Ryan, R.R.

    1997-12-30

    A family of contrast agents for use in magnetic resonance imaging and a method of enhancing the contrast of magnetic resonance images of an object by incorporating a contrast agent of this invention into the object prior to forming the images or during formation of the images. A contrast agent of this invention is a paramagnetic lanthanide hexaazamacrocyclic molecule, where a basic example has the formula LnC{sub 16}H{sub 14}N{sub 6}. Important applications of the invention are in medical diagnosis, treatment, and research, where images of portions of a human body are formed by means of magnetic resonance techniques. 10 figs.

  20. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... Functional (fMRI) - Brain Children's (Pediatric) CT (Computed Tomography) Magnetic Resonance Imaging (MRI) Safety Contrast Materials Children and Radiation Safety Videos related to Children’s ( ...

  1. Magnetic resonance imaging the basics

    CERN Document Server

    Constantinides, Christakis

    2014-01-01

    Magnetic resonance imaging (MRI) is a rapidly developing field in basic applied science and clinical practice. Research efforts in this area have already been recognized with five Nobel prizes awarded to seven Nobel laureates in the past 70 years. Based on courses taught at The Johns Hopkins University, Magnetic Resonance Imaging: The Basics provides a solid introduction to this powerful technology. The book begins with a general description of the phenomenon of magnetic resonance and a brief summary of Fourier transformations in two dimensions. It examines the fundamental principles of physics for nuclear magnetic resonance (NMR) signal formation and image construction and provides a detailed explanation of the mathematical formulation of MRI. Numerous image quantitative indices are discussed, including (among others) signal, noise, signal-to-noise, contrast, and resolution. The second part of the book examines the hardware and electronics of an MRI scanner and the typical measurements and simulations of m...

  2. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... be necessary. Your doctor will explain the exact reason why another exam is requested. Sometimes a follow- ... necessary in trauma situations. Although there is no reason to believe that magnetic resonance imaging harms the ...

  3. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... and may cause you and/or others nearby harm. These items include: jewelry, watches, credit cards and ... no reason to believe that magnetic resonance imaging harms the fetus, pregnant women usually are advised not ...

  4. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... have a personal story about radiology? Share your patient story here Images ... (fMRI) - Brain Head and Neck Cancer Treatment Brain Tumor Treatment Magnetic Resonance Imaging (MRI) ...

  5. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... scanner. top of page How does the procedure work? Unlike conventional x-ray examinations and computed tomography ( ... that magnetic resonance imaging harms the fetus, pregnant women usually are advised not to have an MRI ...

  6. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... is not harmful, but it may cause some medical devices to malfunction. Most orthopedic implants pose no ... Head? Magnetic resonance imaging (MRI) is a noninvasive medical test that physicians use to diagnose medical conditions. ...

  7. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... or thyroid problems. Any of these conditions may influence the decision on whether contrast material will be ... bear denotes child-specific content. Related Articles and Media Catheter Angiography Magnetic Resonance, Functional (fMRI) - Brain Children's ( ...

  8. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... monitors so that your child may watch a movie or TV show during the exam. It is ... patient for magnetic resonance imaging (MRI) exam. View full size with caption Pediatric Content Some imaging tests ...

  9. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... the limitations of MRI of the Head? What is MRI of the Head? Magnetic resonance imaging (MRI) is a noninvasive ... top of page What are some common uses of the procedure? MR imaging of the head is ...

  10. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... the same effect. A very irregular heartbeat may affect the quality of images obtained using techniques that ... Brain Tumor Treatment Magnetic Resonance Imaging (MRI) Safety Alzheimer's Disease Head Injury Brain Tumors Images related to ...

  11. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... have a personal story about radiology? Share your patient story here Images × Image Gallery Magnetic Resonance Imaging (MRI) procedure View full size with caption Pediatric Content Some imaging tests and treatments have special ...

  12. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... patient story here Images × Image Gallery Radiologist prepping patient for magnetic resonance imaging (MRI) exam. View full size with caption Pediatric Content Some imaging tests and treatments have special ...

  13. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... are the limitations of MRI of the Head? What is MRI of the Head? Magnetic resonance imaging ( ... brain) in routine clinical practice. top of page What are some common uses of the procedure? MR ...

  14. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... story about radiology? Share your patient story here Images × Image Gallery Magnetic Resonance Imaging (MRI) procedure View full ... possible charges you will incur. Web page review process: This Web page is reviewed regularly by a ...

  15. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... story about radiology? Share your patient story here Images × Image Gallery Radiologist prepping patient for magnetic resonance imaging ( ... possible charges you will incur. Web page review process: This Web page is reviewed regularly by a ...

  16. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... bones of the skull and spine without radiation. MRI of the brain and spine is used to: detect a variety ... and Media Catheter Angiography Magnetic Resonance, Functional (fMRI) - Brain Children's (Pediatric) CT ... and Radiation Safety ...

  17. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... MRI of the Head? What is MRI of the Head? Magnetic resonance imaging (MRI) is a noninvasive ... of page What are some common uses of the procedure? MR imaging of the head is performed ...

  18. Magnetic response of magnetic molecules with non-collinear local d-tensors

    Directory of Open Access Journals (Sweden)

    J. Schnack

    2009-01-01

    Full Text Available Investigations of molecular magnets are driven both by prospective applications in future storage technology or quantum computing as well as by fundamental questions. Nowadays numerical simulation techniques and computer capabilities make it possible to investigate spin Hamiltonians with realistic arrangements of local anisotropy tensors. In this contribution I will discuss the magnetic response of a small spin system with special emphasis on non-collinear alignments of the local anisotropy axes.

  19. Advances in magnetic resonance 4

    CERN Document Server

    Waugh, John S

    2013-01-01

    Advances in Magnetic Resonance, Volume 4 deals with the relaxation, irradiation, and other dynamical effects that is specific to systems having resolved structure in their magnetic resonance spectra. This book discusses the anisotropic rotation of molecules in liquids by NMR quadrupolar relaxation; rotational diffusion constants; alternating linewidth effect; and theoretical formulations of the problem. The line shapes in high-resolution NMR; matrix representations of the equations of motion; matrix representations of the equations of motion; and intramolecular hydrogen bonds are also delibera

  20. Advances in magnetic resonance 2

    CERN Document Server

    Waugh, John S

    2013-01-01

    Advances in Magnetic Resonance, Volume 2, features a mixture of experimental and theoretical contributions. The book contains four chapters and begins with an ambitious and general treatment of the problem of signal-to-noise ratio in magnetic resonance. This is followed by separate chapters on the interpretation of nuclear relaxation in fluids, with special reference to hydrogen; and various aspects of molecular theory of importance in NMR.

  1. Magnetic resonance imaging; Imagerie par resonance magnetique

    Energy Technology Data Exchange (ETDEWEB)

    Fontanel, F. [Centre Hospitalier, 40 - Mont-de -Marsan (France); Clerc, T. [Centre Hospitalier Universitaire, 76 - Rouen (France); Theolier, S. [Hospice Civils de Lyon, 69 - Lyon (France); Verdenet, J. [Centre Hospitalier Universitaire, 25 - Besancon (France)

    1997-04-01

    The last improvements in nuclear magnetic resonance imaging are detailed here, society by society with an expose of their different devices. In the future the different technological evolutions will be on a faster acquisition, allowing to reduce the examination time, on the development of a more acute cardiac imaging, of a functional neuro-imaging and an interactive imaging for intervention. With the contrast products, staying a longer time in the vascular area, the angiography will find its place. Finally, the studies on magnetic fields should allow to increase the volume to examine. (N.C.).

  2. Advances in magnetic resonance 5

    CERN Document Server

    Waugh, John S

    2013-01-01

    Advances in Magnetic Resonance, Volume 5 deals with the interpretation of ESR spectra and provides descriptions of experimental apparatus. This book discusses the halogen hyperfine interactions; organic radicals in single crystals; pulsed-Fourier-transform nuclear magnetic resonance spectrometer; and inhomogenizer and decoupler. The spectrometers for multiple-pulse NMR; weak collision theory of relaxation in the rotating frame; and spin Hamiltonian for the electron spin resonance of irradiated organic single crystals are also deliberated. This text likewise covers the NMR in helium three and m

  3. Magnetic Resonance Force Microscope Development

    Energy Technology Data Exchange (ETDEWEB)

    Hammel, P.C.; Zhang, Z.; Suh, B.J.; Roukes, M.L.; Midzor, M.; Wigen, P.E.; Childress, J.R.

    1999-06-03

    Our objectives were to develop the Magnetic Resonance Force Microscope (MRFM) into an instrument capable of scientific studies of buried structures in technologically and scientifically important electronic materials such as magnetic multilayer materials. This work resulted in the successful demonstration of MRFM-detected ferromagnetic resonance (FMR) as a microscopic characterization tool for thin magnetic films. Strong FMR spectra obtained from microscopic Co thin films (500 and 1000 angstroms thick and 40 x 200 microns in lateral extent) allowed us to observe variations in sample inhomogeneity and magnetic anisotropy field. We demonstrated lateral imaging in microscopic FMR for the first time using a novel approach employing a spatially selective local field generated by a small magnetically polarized spherical crystallite of yttrium iron garnet. These successful applications of the MRFM in materials studies provided the basis for our successful proposal to DOE/BES to employ the MRF M in studies of buried interfaces in magnetic materials.

  4. Magnetic resonance imaging

    Science.gov (United States)

    Liu, Wei; Fan, Jin; Bai, Jianling; Tang, Pengyu; Chen, Jian; Luo, Yongjun; Zhou, Kuai; Cai, Weihua

    2017-01-01

    Abstract Background and Objectives: Convincing evidence supporting the use of magnetic resonance imaging (MRI) as an effective tool for evaluating cervical sagittal alignment is lacking. This study aims to analyze the differences and correlations between cervical sagittal parameters on x-ray and MRI in patients with cervical disc herniation and to determine whether MRI could substitute for cervical x-ray for measurement of cervical sagittal parameters. Methods: One hundred forty-three adults with cervical disc herniation were recruited. Each patient had both an x-ray and MRI examination of the cervical spine. The cervical sagittal parameters were measured and compared on x-ray and MRI including: C2–C7 Cobb angle, C2–C7 sagittal vertical axis (C2–C7 SVA), cervical tilt (CT), T1 Slope (T1S), and neck tilt (NT). The data were analyzed using a paired-samples t test, a Pearson correlation test, and linear regression. Results: The values of C2–C7 Cobb angle, C2–C7 SVA, CT and T1S on X-ray were larger than those on MRI (P sagittal parameters had a significant correlation with the corresponding one on MRI (r = 0.699, 0.585, 0.574, 0.579 and 0.613, respectively) (C2–C7 Cobb MRI = 0.957 + 0.721 C2–C7 Cobb X, C2–C7 SVA MRI = 6.423 + 0.500 C2–C7 SVAX, CT MRI = 3.121 + 0.718 CTX, T1S MRI = 7.416 + 0.613 T1SX, NT MRI = 22.548 + 0.601 NTX). Conclusion: Although MRI and x-ray measurements of cervical sagittal parameters were different, there were significant correlations between the results. MRI could be used to evaluate the sagittal balance of the cervical spine with great reliability. PMID:28953681

  5. Characterizing the magnetic susceptibility tensor of lanthanide-containing polymethylated-DOTA complexes

    Energy Technology Data Exchange (ETDEWEB)

    Strickland, Madeleine [National Institutes of Health, Laboratory of Molecular Biophysics, Biochemistry and Biophysics Center, National Heart, Lung, and Blood Institute (United States); Schwieters, Charles D. [National Institutes of Health, Office of Intramural Research, Center for Information Technology (United States); Göbl, Christoph [Technische Universität München, Department of Chemistry (Germany); Opina, Ana C. L. [National Institutes of Health, Imaging Probe Development Center, National Heart, Lung, and Blood Institute (United States); Strub, Marie-Paule [National Institutes of Health, Laboratory of Molecular Biophysics, Biochemistry and Biophysics Center, National Heart, Lung, and Blood Institute (United States); Swenson, Rolf E.; Vasalatiy, Olga [National Institutes of Health, Imaging Probe Development Center, National Heart, Lung, and Blood Institute (United States); Tjandra, Nico, E-mail: tjandran@nhlbi.nih.gov [National Institutes of Health, Laboratory of Molecular Biophysics, Biochemistry and Biophysics Center, National Heart, Lung, and Blood Institute (United States)

    2016-10-15

    Lanthanide complexes based on the DOTA (1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid) cage are commonly used as phase contrast agents in magnetic resonance imaging, but can also be utilized in structural NMR applications due to their ability to induce either paramagnetic relaxation enhancement or a pseudocontact shift (PCS) depending on the choice of the lanthanide. The size and sign of the PCS for any given atom is determined by its coordinates relative to the metal center, and the characteristics of the lanthanide’s magnetic susceptibility tensor. Using a polymethylated DOTA tag (Ln-M8-SPy) conjugated to ubiquitin, we calculated the position of the metal center and characterized the susceptibility tensor for a number of lanthanides (dysprosium, thulium, and ytterbium) under a range of pH and temperature conditions. We found that there was a difference in temperature sensitivity for each of the complexes studied, which depended on the size of the lanthanide ion as well as the isomeric state of the cage. Using {sup 17}O-NMR, we confirmed that the temperature sensitivity of the compounds was enhanced by the presence of an apically bound water molecule. Since amide-containing lanthanide complexes are known to be pH sensitive and can be used as probes of physiological pH, we also investigated the effect of pH on the Ln-M8-SPy susceptibility tensor, but we found that the changes in this pH range (5.0–7.4) were not significant.

  6. Estimation of the magnetic field gradient tensor using the Swarm constellation

    DEFF Research Database (Denmark)

    Kotsiaros, Stavros; Finlay, Chris; Olsen, Nils

    2014-01-01

    For the first time, part of the magnetic field gradient tensor is estimated in space by the Swarm mission. We investigate the possibility of a more complete estimation of the gradient tensor exploiting the Swarm constellation. The East-West gradients can be approximated by observations from...

  7. Bifurcation magnetic resonance in films magnetized along hard magnetization axis

    Energy Technology Data Exchange (ETDEWEB)

    Vasilevskaya, Tatiana M., E-mail: t_vasilevs@mail.ru [Ulyanovsk State University, Leo Tolstoy 42, 432017 Ulyanovsk (Russian Federation); Sementsov, Dmitriy I.; Shutyi, Anatoliy M. [Ulyanovsk State University, Leo Tolstoy 42, 432017 Ulyanovsk (Russian Federation)

    2012-09-15

    We study low-frequency ferromagnetic resonance in a thin film magnetized along the hard magnetization axis performing an analysis of magnetization precession dynamics equations and numerical simulation. Two types of films are considered: polycrystalline uniaxial films and single-crystal films with cubic magnetic anisotropy. An additional (bifurcation) resonance initiated by the bistability, i.e. appearance of two closely spaced equilibrium magnetization states is registered. The modification of dynamic modes provoked by variation of the frequency, amplitude, and magnetic bias value of the ac field is studied. Both steady and chaotic magnetization precession modes are registered in the bifurcation resonance range. - Highlights: Black-Right-Pointing-Pointer An additional bifurcation resonance arises in a case of a thin film magnetized along HMA. Black-Right-Pointing-Pointer Bifurcation resonance occurs due to the presence of two closely spaced equilibrium magnetization states. Black-Right-Pointing-Pointer Both regular and chaotic precession modes are realized within bifurcation resonance range. Black-Right-Pointing-Pointer Appearance of dynamic bistability is typical for bifurcation resonance.

  8. Full Tensor Eigenvector Analysis on Air-Borne Magnetic Gradiometer Data for the Detection of Dipole-Like Magnetic Sources

    OpenAIRE

    Zuo, Boxin; Wang, Lizhe; Chen, Weitao

    2017-01-01

    The detection of dipole-like sources, such as unexploded ordnances (UXO) and other metallic objects, based on a magnetic gradiometer system, has been increasingly applied in recent years. In this paper, a novel dipole-like source detection algorithm, based on eigenvector analysis with magnetic gradient tensor data interpretation is presented. Firstly, the theoretical basis of the eigenvector decomposition of magnetic gradient tensor is analyzed. Then, a detection algorithm is proposed by usin...

  9. Interventional Cardiovascular Magnetic Resonance Imaging

    Science.gov (United States)

    Saikus, Christina E.; Lederman, Robert J.

    2010-01-01

    Cardiovascular magnetic resonance (CMR) combines excellent soft-tissue contrast, multiplanar views, and dynamic imaging of cardiac function without ionizing radiation exposure. Interventional cardiovascular magnetic resonance (iCMR) leverages these features to enhance conventional interventional procedures or to enable novel ones. Although still awaiting clinical deployment, this young field has tremendous potential. We survey promising clinical applications for iCMR. Next, we discuss the technologies that allow CMR-guided interventions and, finally, what still needs to be done to bring them to the clinic. PMID:19909937

  10. Advances in magnetic resonance 8

    CERN Document Server

    Waugh, John S

    2013-01-01

    Advances in Magnetic Resonance, Volume 8 describes the magnetic resonance in spin polarization and saturation transfer. This book discusses the theory of chemically induced dynamic spin polarization; basic results for the radical-pair mechanism; and optical spin polarization in molecular crystals. The theory of optical electronic polarization (OEP); NMR in flowing systems; and applications of NMR in a flowing liquid are also elaborated. This text likewise covers the saturation transfer spectroscopy; studies of spin labels in the intermediate and fast motion regions; and spin-density matrix and

  11. Migraine and magnetic resonance spectroscopy

    DEFF Research Database (Denmark)

    Younis, Samaira; Hougaard, Anders; Vestergaard, Mark B.

    2017-01-01

    Purpose of review: To present an updated and streamlined overview of the metabolic and biochemical aspect of the migraine pathophysiology based on findings from phosphorous (31P) and hydrogen (1H) magnetic resonance spectroscopy (MRS) studies. Recent findings: Despite of the variation in the meth......Purpose of review: To present an updated and streamlined overview of the metabolic and biochemical aspect of the migraine pathophysiology based on findings from phosphorous (31P) and hydrogen (1H) magnetic resonance spectroscopy (MRS) studies. Recent findings: Despite of the variation...

  12. The general dielectric tensor for bi-kappa magnetized plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Gaelzer, R., E-mail: rudi.gaelzer@ufrgs.br; Ziebell, L. F., E-mail: luiz.ziebell@ufrgs.br; Meneses, A. R., E-mail: anemeneses@gmail.com [Instituto de Física, UFRGS, 91501-970 Porto Alegre, RS (Brazil)

    2016-06-15

    In this paper, we derive the dielectric tensor for a plasma containing particles described by an anisotropic superthermal (bi-kappa) velocity distribution function. The tensor components are written in terms of the two-variables kappa plasma special functions, recently defined by Gaelzer and Ziebell [Phys. Plasmas 23, 022110 (2016)]. We also obtain various new mathematical properties for these functions, which are useful for the analytical treatment, numerical implementation, and evaluation of the functions and, consequently, of the dielectric tensor. The formalism developed here and in the previous paper provides a mathematical framework for the study of electromagnetic waves propagating at arbitrary angles and polarizations in a superthermal plasma.

  13. The general dielectric tensor for bi-kappa magnetized plasmas

    CERN Document Server

    Gaelzer, Rudi; Meneses, Anelise Ramires

    2016-01-01

    In this paper we derive the dielectric tensor for a plasma containing particles described by an anisotropic superthermal (bi-kappa) velocity distribution function. The tensor components are written in terms of the two-variables kappa plasma special functions, recently defined by Gaelzer and Ziebell [Phys. Plasmas 23, 022110 (2016)]. We also obtain various new mathematical properties for these functions, which are useful for the analytical treatment, numerical implementation and evaluation of the functions and, consequently, of the dielectric tensor. The formalism developed here and in the previous paper provides a mathematical framework for the study of electromagnetic waves propagating at arbitrary angles and polarizations in a superthermal plasma.

  14. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician ... Magnetic resonance imaging (MRI) is a noninvasive medical test that physicians use to diagnose medical conditions. MRI ...

  15. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician ... Magnetic resonance imaging (MRI) is a noninvasive medical test that physicians use to diagnose medical conditions. MRI ...

  16. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... the brain caused by an injury or a stroke diagnose infectious or autoimmune diseases like encephalopathy or ... broad range of conditions, including cancer, heart and vascular disease, and muscular and bone ... (Pediatric) CT (Computed Tomography) Magnetic Resonance Imaging ( ...

  17. Evanescent Waves Nuclear Magnetic Resonance

    DEFF Research Database (Denmark)

    Halidi, El Mohamed; Nativel, Eric; Akel, Mohamad

    2016-01-01

    Nuclear Magnetic Resonance spectroscopy and imaging can be classified as inductive techniques working in the near- to far-field regimes. We investigate an alternative capacitive detection with the use of micrometer sized probes positioned at sub wavelength distances of the sample in order...

  18. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... are the limitations of Children’s (Pediatric) MRI? What is Children’s (Pediatric) MRI? Magnetic resonance imaging (MRI) is ... top of page What are some common uses of the procedure? MRI is used to help diagnose ...

  19. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... What are the limitations of Children’s (Pediatric) MRI? What is Children’s (Pediatric) MRI? Magnetic resonance imaging (MRI) ... to a digital cloud server. top of page What are some common uses of the procedure? MRI ...

  20. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... of which shows a thin slice of the body. The images can then be studied from different angles by ... about radiology? Share your patient story here Images ... Articles and Media Catheter Angiography Magnetic Resonance, Functional (fMRI) - Brain Children's ( ...

  1. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... of which shows a thin slice of the body. The images can then be studied from different angles by ... about radiology? Share your patient story here Images ... Related Articles and Media MR Angiography (MRA) Magnetic Resonance, Functional (fMRI) - Brain ...

  2. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... structures of the brain and can also provide functional information (fMRI) in selected cases. MR images of ... Articles and Media MR Angiography (MRA) Magnetic Resonance, Functional (fMRI) - Brain Head and Neck Cancer Treatment Brain ...

  3. Magnetic Resonance with Squeezed Microwaves

    Science.gov (United States)

    Bienfait, A.; Campagne-Ibarcq, P.; Kiilerich, A. H.; Zhou, X.; Probst, S.; Pla, J. J.; Schenkel, T.; Vion, D.; Esteve, D.; Morton, J. J. L.; Moelmer, K.; Bertet, P.

    2017-10-01

    Vacuum fluctuations of the electromagnetic field set a fundamental limit to the sensitivity of a variety of measurements, including magnetic resonance spectroscopy. We report the use of squeezed microwave fields, which are engineered quantum states of light for which fluctuations in one field quadrature are reduced below the vacuum level, to enhance the detection sensitivity of an ensemble of electronic spins at millikelvin temperatures. By shining a squeezed vacuum state on the input port of a microwave resonator containing the spins, we obtain a 1.2-dB noise reduction at the spectrometer output compared to the case of a vacuum input. This result constitutes a proof of principle of the application of quantum metrology to magnetic resonance spectroscopy.

  4. Magnetic Resonance Imaging (MRI): Brain (For Parents)

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español Magnetic Resonance Imaging (MRI): Brain KidsHealth / For Parents / Magnetic Resonance Imaging (MRI): Brain What's in this article? What It ...

  5. Magnetic Resonance Imaging (MRI): Dynamic Pelvic Floor

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Magnetic Resonance Imaging (MRI) – Dynamic Pelvic Floor Dynamic pelvic floor magnetic resonance imaging (MRI) is a noninvasive test that uses a ...

  6. International Society for Magnetic Resonance in Medicine

    Science.gov (United States)

    ... information. And check out the MRM blog: Magnetic Resonance in Medicine Highlights Featured Journal Research Submit Research | ... Meetings Connect With Us International Society for Magnetic Resonance in Medicine 2300 Clayton Road, Suite 620 | Concord, ...

  7. Your Radiologist Explains Magnetic Resonance Angiography (MRA)

    Medline Plus

    Full Text Available ... by Image/Video Gallery Your Radiologist Explains Magnetic Resonance Angiography (MRA) Transcript Welcome to Radiology Info dot ... d like to talk with you about magnetic resonance angiography, or as it’s commonly known, MRA. MRA ...

  8. Chiral discrimination in nuclear magnetic resonance spectroscopy

    Science.gov (United States)

    Lazzeretti, Paolo

    2017-11-01

    Chirality is a fundamental property of molecules whose spatial symmetry is characterized by the absence of improper rotations, making them not superimposable to their mirror image. Chiral molecules constitute the elementary building blocks of living species and one enantiomer is favoured in general (e.g. L-aminoacids and D-sugars pervade terrestrial homochiral biochemistry) because most chemical reactions producing natural substances are enantioselective. Since the effect of chiral chemicals and drugs on living beings can be markedly different between enantiomers, the quest for practical spectroscopical methods to scrutinize chirality is an issue of great importance and interest. Nuclear magnetic resonance (NMR) is a topmost analytical technique, but spectrometers currently used are ‘blind’ to chirality, i.e. unable to discriminate the two mirror-image forms of a chiral molecule, because, in the absence of a chiral solvent, the spectral parameters, chemical shifts and spin-spin coupling constants are identical for enantiomers. Therefore, the development of new procedures for routine chiral recognition would offer basic support to scientists. However, in the presence of magnetic fields, a distinction between true and false chirality is mandatory. The former epitomizes natural optical activity, which is rationalized by a time-even pseudoscalar, i.e. the trace of a second-rank tensor, the mixed electric dipole/magnetic dipole polarizability. The Faraday effect, magnetic circular dichroism and magnetic optical activity are instead related to a time-odd axial vector. The present review summarizes recent theoretical and experimental efforts to discriminate enantiomers via NMR spectroscopy, with the focus on the deep connection between chirality and symmetry properties under the combined set of fundamental discrete operations, namely charge conjugation, parity (space inversion) and time (motion) reversal.

  9. Determining anisotropic conductivity using diffusion tensor imaging data in magneto-acoustic tomography with magnetic induction

    Science.gov (United States)

    Ammari, Habib; Qiu, Lingyun; Santosa, Fadil; Zhang, Wenlong

    2017-12-01

    In this paper we present a mathematical and numerical framework for a procedure of imaging anisotropic electrical conductivity tensor by integrating magneto-acoutic tomography with data acquired from diffusion tensor imaging. Magneto-acoustic tomography with magnetic induction (MAT-MI) is a hybrid, non-invasive medical imaging technique to produce conductivity images with improved spatial resolution and accuracy. Diffusion tensor imaging (DTI) is also a non-invasive technique for characterizing the diffusion properties of water molecules in tissues. We propose a model for anisotropic conductivity in which the conductivity is proportional to the diffusion tensor. Under this assumption, we propose an optimal control approach for reconstructing the anisotropic electrical conductivity tensor. We prove convergence and Lipschitz type stability of the algorithm and present numerical examples to illustrate its accuracy and feasibility.

  10. Magnetic Resonance Imaging (MRI) (For Parents)

    Science.gov (United States)

    ... Help a Child Cope With a Parent's Suicide? Magnetic Resonance Imaging (MRI) KidsHealth > For Parents > Magnetic Resonance Imaging (MRI) Print A A A What's ... Child If You Have Questions What It Is Magnetic resonance imaging (MRI) is a safe and painless ...

  11. Resonances at the LHC beyond the Higgs. The Scalar/Tensor case

    Energy Technology Data Exchange (ETDEWEB)

    Kilian, Wolfgang [Department of Physics, University of Siegen (Germany); Ohl, Thorsten [Faculty of Physics and Astronomy, Wuerzburg University (Germany); Reuter, Juergen [DESY, Theory Group, Hamburg (Germany); Sekulla, Marco [Institute for Theoretical Physics, Karlsruhe Institute of Technology (Germany)

    2016-07-01

    Weak vector boson scattering (VBS) at high energies will be one of the key measurements in current and upcoming LHC runs. It is most sensitive to any new physics associated with electroweak symmetry breaking. However, a conventional EFT analysis will fail at high energies. In this talk I present an extension of the bottom-up EFT, which includes the 125 GeV Higgs boson. Within a simplified model the effects of generic tensor and scalar resonances are considered. The spurious degrees of freedom of tensor resonances that would lead to bad high-energy behavior are treated using a generalization of the Stueckelberg formalism. To ensure that the scattering amplitudes are well behaved on the whole phase space, the T-matrix unitarization procedure is used. The implementation of this model into the Monte Carlo generator WHIZARD can be used for further studies at the LHC as I will show with exemplary plots.

  12. Resonant magnetic fields from inflation

    CERN Document Server

    Byrnes, Christian T; Jain, Rajeev Kumar; Urban, Federico R

    2012-01-01

    We propose a novel scenario to generate primordial magnetic fields during inflation induced by an oscillating coupling of the electromagnetic field to the inflaton. This resonant mechanism has two key advantages over previous proposals. First of all, it generates a narrow band of magnetic fields at any required wavelength, thereby allaying the usual problem of a strongly blue spectrum and its associated backreaction. Secondly, it avoids the need for a strong coupling as the coupling is oscillating rather than growing or decaying exponentially. Despite these major advantages, we find that the backreaction is still far too large during inflation if the generated magnetic fields are required to have a strength of ${\\cal O}(10^{-15}\\, \\Gauss)$ today on observationally interesting scales. We provide a more general no-go argument, proving that this problem will apply to any model in which the magnetic fields are generated on subhorizon scales and freeze after horizon crossing.

  13. Magnetic resonance tomography in syringomyelia

    Energy Technology Data Exchange (ETDEWEB)

    Koehler, D.; Treisch, J.; Hertel, G.; Schoerner, W.; Fiegler, W.

    1985-12-01

    Thirteen patients with a clinical diagnosis of syringomyelia were examined by nuclear tomography (0.35 T magnet) in the spin-echo mode. In all thirteen patients, the T1 images (Se 400/35) showed a longitudinal cavity with a signal intensity of CSF. The shape and extent of the syrinx could be adequately demonstrated in 12 of the 13 examinations. Downward displacement of the cerebellar tonsils was seen in eight cases. The examination took between half and one hour. Advantages of magnetic resonance tomography (nuclear tomography) include the absence of artifacts, images in the line of the lesion and its non-invasiveness.

  14. Migration transformation of two-dimensional magnetic vector and tensor fields

    DEFF Research Database (Denmark)

    Zhdanov, Michael; Cai, Hongzhu; Wilson, Glenn

    2012-01-01

    We introduce a new method of rapid interpretation of magnetic vector and tensor field data, based on ideas of potential field migration which extends the general principles of seismic and electromagnetic migration to potential fields. 2-D potential field migration represents a direct integral...... transformation of the observed magnetic fields into a subsurface susceptibility distribution, which can be used for interpretation or as an a priori model for subsequent regularized inversion. Potential field migration is very stable with respect to noise in the observed data because the transform is reduced...... to the downward continuation of a well-behaved analytical function. We present case studies for imaging of SQUID-based magnetic tensor data acquired over a magnetite skarn at Tallawang, Australia. The results obtained from magnetic tensor field migration agree very well with both Euler deconvolution and the known...

  15. Magnetic resonance imaging in hemosiderosis

    Energy Technology Data Exchange (ETDEWEB)

    Kessing, P.H.L.; Falke, T.H.M.; Steiner, R.M.; Bloem, H.; Peters, A. (Rijksuniversiteit Leiden (Netherlands). Academisch Ziekenhuis)

    1985-01-15

    The case of a patient with iron deposition disease is presented to illustrate the value of magnetic resonance imaging (MRI) in the evaluation of this entity. The image characteristics of MRI are discussed and the results are compared with those of computer tomography (CT). The importance of a decrease in T2 relaxation time as the determinant parameter for signal intensity in MRI of the liver in such patients is emphasized.

  16. Magnetic resonance and its applications

    CERN Document Server

    Chizhik, Vladimir I; Donets, Alexey V; Frolov, Vyacheslav V; Komolkin, Andrei V; Shelyapina, Marina G

    2014-01-01

    The book provides a basic understanding of the underlying theory, fundamentals and applications of magnetic resonance The book implies a few levels of the consideration (from simple to complex) of phenomena, that can be useful for different groups of readers The introductory chapter provides the necessary underpinning knowledge for newcomers to the methods The exposition of theoretical materials goes from initial to final formulas through detailed intermediate expressions.

  17. Observation of vector and tensor light shifts in 87Rb using near-resonant, stimulated Raman spectroscopy

    Science.gov (United States)

    Hu, Qing-Qing; Freier, Christian; Sun, Yuan; Leykauf, Bastian; Schkolnik, Vladimir; Yang, Jun; Krutzik, Markus; Peters, Achim

    2018-01-01

    We present the derivation of the frequency-dependent scalar, vector, and tensor dynamical polarizabilities for the two hyperfine levels of the 87Rb atom 5 s ground state. Based on the characterization of the dynamical polarizabilities, we analyze and measure the differential vector and tensor light shift between the 5 s ground-state sublevels with near-resonant, stimulated Raman transitions. These results clarify that the tensor polarizabilities for the ground states of alkali atoms are absent when the light field is far detuned from the atomic resonance and the total electronic angular momentum J is a good quantum number. In the near-resonant case, the light shifts are nontrivial and the determination of the frequency-dependent vector and tensor dynamic polarizabilities will help to achieve higher fidelities for applications of neutral atoms in quantum information and precision measurements.

  18. Are Movement Artifacts in Magnetic Resonance Imaging a Real Problem?-A Narrative Review

    DEFF Research Database (Denmark)

    Havsteen, Inger; Ohlhues, Anders; Madsen, Kristoffer H

    2017-01-01

    Movement artifacts compromise image quality and may interfere with interpretation, especially in magnetic resonance imaging (MRI) applications with low signal-to-noise ratio such as functional MRI or diffusion tensor imaging, and when imaging small lesions. High image resolution has high sensitiv...

  19. Relativistic effects in the intermolecular interaction-induced nuclear magnetic resonance parameters of xenon dimer

    DEFF Research Database (Denmark)

    Hanni, Matti; Lantto, Perttu; Ilias, Miroslav

    2007-01-01

    Relativistic effects on the 129Xe nuclear magnetic resonance shielding and 131Xe nuclear quadrupole coupling (NQC) tensors are examined in the weakly bound Xe2 system at different levels of theory including the relativistic four-component Dirac-Hartree-Fock (DHF) method. The intermolecular intera...

  20. Phosphorus-doped thin silica films characterized by magic-angle spinning nuclear magnetic resonance spectroscopy

    DEFF Research Database (Denmark)

    Jacobsen, H.J.; Skibsted, J.; Kristensen, Martin

    2001-01-01

    Magic-angle spinning nuclear magnetic resonance spectra of 31P and 29Si have been achieved for a thin silica film doped with only 1.8% 31P and deposited by plasma enhanced chemical vapor deposition on a pure silicon wafer. The observation of a symmetric 31P chemical shift tensor is consistent...

  1. Advances in magnetic resonance 3

    CERN Document Server

    Waugh, John S

    2013-01-01

    Advances in Magnetic Resonance, Volume 3, describes a number of important developments which are finding increasing application by chemists. The book contains five chapters and begins with a discussion of how the properties of random molecular rotations reflect themselves in NMR and how they show up, often differently, in other kinds of experiments. This is followed by separate chapters on the Kubo method, showing its equivalence to the Redfield approach in the cases of most general interest; the current state of dynamic nuclear polarization measurements in solutions and what they tell us abou

  2. [Use of magnetic resonance imaging].

    Science.gov (United States)

    Chabanova, Elizaveta; Larsen, Lone; Løgager, Vibeke Berg; Møller, Jakob M; Thomsen, Henrik S

    2014-01-06

    Magnetic resonance imaging (MRI) is one of the four imaging modalities used in radiology. In contrast to computed tomography (CT), it does not use radiation. MRI is still developing and the diagnostic capabilities are growing. There are many indications for MRI and in some fields it has replaced CT. With few exceptions MRI is used mainly for elective examinations, and because of the new techniques like diffusion and perfusion MRI in cancer imaging the use is increasing both with regard to work-up and follow-up. For non-malignant lesions MRI is increasingly used thanks to its great soft-tissue contrast capabilities.

  3. Tunable Magnetic Resonance in Microwave Spintronics Devices

    Science.gov (United States)

    Chen, Yunpeng; Fan, Xin; Xie, Yunsong; Zhou, Yang; Wang, Tao; Wilson, Jeffrey D.; Simons, Rainee N.; Chui, Sui-Tat; Xiao, John Q.

    2015-01-01

    Magnetic resonance is one of the key properties of magnetic materials for the application of microwave spintronics devices. The conventional method for tuning magnetic resonance is to use an electromagnet, which provides very limited tuning range. Hence, the quest for enhancing the magnetic resonance tuning range without using an electromagnet has attracted tremendous attention. In this paper, we exploit the huge exchange coupling field between magnetic interlayers, which is on the order of 4000 Oe and also the high frequency modes of coupled oscillators to enhance the tuning range. Furthermore, we demonstrate a new scheme to control the magnetic resonance frequency. Moreover, we report a shift in the magnetic resonance frequency as high as 20 GHz in CoFe based tunable microwave spintronics devices, which is 10X higher than conventional methods.

  4. Migraine and magnetic resonance spectroscopy

    DEFF Research Database (Denmark)

    Younis, Samaira; Hougaard, Anders; Vestergaard, Mark B.

    2017-01-01

    Purpose of review: To present an updated and streamlined overview of the metabolic and biochemical aspect of the migraine pathophysiology based on findings from phosphorous (31P) and hydrogen (1H) magnetic resonance spectroscopy (MRS) studies. Recent findings: Despite of the variation in the meth......Purpose of review: To present an updated and streamlined overview of the metabolic and biochemical aspect of the migraine pathophysiology based on findings from phosphorous (31P) and hydrogen (1H) magnetic resonance spectroscopy (MRS) studies. Recent findings: Despite of the variation...... in the methodology and quality of the MRS migraine studies over time, some results were consistent and reproducible. 31P-MRS studies suggested reduced availability of neuronal energy and implied a mitochondrial dysfunction in the migraine brain. 1H-MRS studies reported interictal abnormalities in the excitatory...... and inhibitory neurotransmitters, glutamate and g-aminobutyric acid (GABA), suggesting persistent altered excitability in migraine patients. N-Acetylaspartate levels were decreased in migraine, probably due to a mitochondrial dysfunction and abnormal energy metabolism. The reported abnormalities may increase...

  5. Improvements in Mechanical Detection of Magnetic Resonance

    National Research Council Canada - National Science Library

    Fainchtein, Raul

    2005-01-01

    This program intended to provide substantial improvements to conditions that affect imaging nanoscale structures with atomic resolution and chemical specificity by magnetic resonance force microscopy...

  6. Advanced techniques in magnetic resonance imaging of the brain in children with ADHD

    Energy Technology Data Exchange (ETDEWEB)

    Pastura, Giuseppe, E-mail: giuseppe.pastura@terra.com.b [Universidade Federal do Rio de Janeiro (UFRJ), Rio de Janeiro, RJ (Brazil). Instituto de Puericultura e Pediatria Martagao Gesteira. Dept. de Pediatria; Mattos, Paulo [Universidade Federal do Rio de Janeiro (UFRJ), Rio de Janeiro, RJ (Brazil). Instituto de Puericultura e Pediatria Martagao Gesteira. Dept. de Psiquiatria; Gasparetto, Emerson Leandro [Universidade Federal do Rio de Janeiro (UFRJ), Rio de Janeiro, RJ (Brazil). Instituto de Puericultura e Pediatria Martagao Gesteira. Dept. de Radiologia; Araujo, Alexandra Prufer de Queiroz Campos [Universidade Federal do Rio de Janeiro (UFRJ), Rio de Janeiro, RJ (Brazil). Instituto de Puericultura e Pediatria Martagao Gesteira. Dept. de Neuropediatria

    2011-04-15

    Attention deficit hyperactivity disorder (ADHD) affects about 5% of school-aged child. Previous published works using different techniques of magnetic resonance imaging (MRI) have demonstrated that there may be some differences between the brain of people with and without this condition. This review aims at providing neurologists, pediatricians and psychiatrists an update on the differences between the brain of children with and without ADHD using advanced techniques of magnetic resonance imaging such as diffusion tensor imaging, brain volumetry and cortical thickness, spectroscopy and functional MRI. Data was obtained by a comprehensive, non-systematic review of medical literature. The regions with a greater number of abnormalities are splenium of the corpus callosum, cingulated gyrus, caudate nucleus, cerebellum, striatum, frontal and temporal cortices. The brain regions where abnormalities are observed in studies of diffusion tensor, volumetry, spectroscopy and cortical thickness are the same involved in neurobiological theories of ADHD coming from studies with functional magnetic resonance imaging. (author)

  7. Rigorous expansion of electromagnetic Green's tensor of lossy resonators in open systems

    Science.gov (United States)

    Chen, Parry Y.; Bergman, David J.; Sivan, Yonatan

    2017-08-01

    We obtain an eigenmode expansion of the electromagnetic Green's tensor G(r,r') for lossy resonators in open systems, which is simple yet complete. This enables rapid simulations by providing the spatial variation of G0(r,r') over both r and r' in one simulation. Few eigenmodes are often necessary for nanostructures, facilitating both analytic calculations and unified insight into computationally intensive phenomena such as Purcell enhancement, radiative heat transfer, van der Waals forces, and Förster resonance energy transfer. We bypass all implementation and completeness issues associated with the alternative quasinormal eigenmode methods, by defining modes with permittivity rather than frequency as the eigenvalue. Thus, modes decay rather than diverge at infinity, and are defined by a linear eigenvalue problem, readily implemented using any numerical method. We demonstrate its general implementation in COMSOL Multiphysics, using the default in-built tools.

  8. Incompressible Steady Flow with Tensor Conductivity Leaving a Transverse Magnetic Field

    Energy Technology Data Exchange (ETDEWEB)

    Witalis, E.A.

    1965-12-15

    The straight channel flow of an inviscid, incompressible fluid with tensor conductivity is considered when the flow leaves a region of constant transverse magnetic field. The channel walls are taken to be insulating, and an eddy current system arises. This is investigated by the method of magnetic field analysis as given by Witalis. The spatial distribution of magnetic field and ohmic power loss, both parallel and transverse to the flow, are given as functions of the Hall parameter with consideration also to the magnetic Reynolds number of the fluid. MHD power generator aspects of this problem and the results are discussed.

  9. Magnetic resonance imaging markers for early diagnosis of Parkinson's disease☆

    Science.gov (United States)

    Marino, Silvia; Ciurleo, Rosella; Di Lorenzo, Giuseppe; Barresi, Marina; De Salvo, Simona; Giacoppo, Sabrina; Bramanti, Alessia; Lanzafame, Pietro; Bramanti, Placido

    2012-01-01

    Parkinson's disease (PD) is a neurodegenerative disorder characterized by selective and progressive degeneration, as well as loss of dopaminergic neurons in the substantia nigra. In PD, approximately 60-70% of nigrostriatal neurons are degenerated and 80% of content of the striatal dopamine is reduced before the diagnosis can be established according to widely accepted clinical diagnostic criteria. This condition describes a stage of disease called “prodromal”, where non-motor symptoms, such as olfactory dysfunction, constipation, rapid eye movement behaviour disorder, depression, precede motor sign of PD. Detection of prodromal phase of PD is becoming an important goal for determining the prognosis and choosing a suitable treatment strategy. In this review, we present some non-invasive instrumental approaches that could be useful to identify patients in the prodromal phase of PD or in an early clinical phase, when the first motor symptoms begin to be apparent. Conventional magnetic resonance imaging (MRI) and advanced MRI techniques, such as magnetic resonance spectroscopy imaging, diffusion-weighted and diffusion tensor imaging and functional MRI, are useful to differentiate early PD with initial motor symptoms from atypical parkinsonian disorders, thus, making easier early diagnosis. Functional MRI and diffusion tensor imaging techniques can show abnormalities in the olfactory system in prodromal PD. PMID:25745453

  10. Magnetic resonance imaging markers for early diagnosis of Parkinson's disease.

    Science.gov (United States)

    Marino, Silvia; Ciurleo, Rosella; Di Lorenzo, Giuseppe; Barresi, Marina; De Salvo, Simona; Giacoppo, Sabrina; Bramanti, Alessia; Lanzafame, Pietro; Bramanti, Placido

    2012-03-15

    Parkinson's disease (PD) is a neurodegenerative disorder characterized by selective and progressive degeneration, as well as loss of dopaminergic neurons in the substantia nigra. In PD, approximately 60-70% of nigrostriatal neurons are degenerated and 80% of content of the striatal dopamine is reduced before the diagnosis can be established according to widely accepted clinical diagnostic criteria. This condition describes a stage of disease called "prodromal", where non-motor symptoms, such as olfactory dysfunction, constipation, rapid eye movement behaviour disorder, depression, precede motor sign of PD. Detection of prodromal phase of PD is becoming an important goal for determining the prognosis and choosing a suitable treatment strategy. In this review, we present some non-invasive instrumental approaches that could be useful to identify patients in the prodromal phase of PD or in an early clinical phase, when the first motor symptoms begin to be apparent. Conventional magnetic resonance imaging (MRI) and advanced MRI techniques, such as magnetic resonance spectroscopy imaging, diffusion-weighted and diffusion tensor imaging and functional MRI, are useful to differentiate early PD with initial motor symptoms from atypical parkinsonian disorders, thus, making easier early diagnosis. Functional MRI and diffusion tensor imaging techniques can show abnormalities in the olfactory system in prodromal PD.

  11. Magnetic Resonance Imaging of Electrolysis.

    Science.gov (United States)

    Meir, Arie; Hjouj, Mohammad; Rubinsky, Liel; Rubinsky, Boris

    2015-01-01

    This study explores the hypothesis that Magnetic Resonance Imaging (MRI) can image the process of electrolysis by detecting pH fronts. The study has relevance to real time control of cell ablation with electrolysis. To investigate the hypothesis we compare the following MR imaging sequences: T1 weighted, T2 weighted and Proton Density (PD), with optical images acquired using pH-sensitive dyes embedded in a physiological saline agar solution phantom treated with electrolysis and discrete measurements with a pH microprobe. We further demonstrate the biological relevance of our work using a bacterial E. Coli model, grown on the phantom. The results demonstrate the ability of MRI to image electrolysis produced pH changes in a physiological saline phantom and show that these changes correlate with cell death in the E. Coli model grown on the phantom. The results are promising and invite further experimental research. PMID:25659942

  12. Magnetic Resonance Imaging of Neurosarcoidosis

    Directory of Open Access Journals (Sweden)

    Daniel T Ginat

    2011-01-01

    Full Text Available Neurosarcoidosis is an uncommon condition with protean manifestations. Magnetic resonance imaging (MRI is often used in the diagnostic evaluation and follow-up of patients with neurosarcoidosis. Therefore, familiarity with the variety of MRI appearances is important. In this pictorial essay, the range of possible patterns of involvement in neurosarcoidosis are depicted and discussed. These include intracranial and spine leptomeningeal involvement, cortical and cerebral white matter lesions, corpus callosum involvement, sellar and suprasellar involvement, periventricular involvement, cranial nerve involvement, cavernous sinus involvement, hydrocephalus, dural involvement, ischemic lesions, perivascular involvement, orbit lesions, osseous involvement, nerve root involvement, and spinal cord intramedullary involvement. Differential diagnoses for each pattern of involvement of neurosarcoidosis are also provided.

  13. Your Radiologist Explains Magnetic Resonance Angiography (MRA)

    Medline Plus

    Full Text Available ... Sponsored by Image/Video Gallery Your Radiologist Explains Magnetic Resonance Angiography (MRA) Transcript Welcome to Radiology Info ... I’d like to talk with you about magnetic resonance angiography, or as it’s commonly known, MRA. ...

  14. Single voxel magnetic resonance spectroscopy in distinguishing ...

    African Journals Online (AJOL)

    Objective: Assess diagnostic utility of combined magnetic resonance imaging and magnetic resonance spectroscopy (MRI, MRS) in differentiating focal neoplastic lesions from focal non- neoplastic (infective or degenerative) brain lesions. Design: Descriptive, analytical - prospective study. Setting: The Aga Khan University ...

  15. Intraoperative magnetic resonance imaging and meningioma surgery

    African Journals Online (AJOL)

    Objective: To determine if intraoperative magnetic resonance imaging improves surgical resection and postoperative outcome of intracranial meningioma. Study design: Prospective, non-randomized, cohort study. Method: Intraoperative Magnetic Resonance Imaging (iMRI) was used to evaluate patients with meningioma ...

  16. Magnetic resonance imaging of the prostate

    DEFF Research Database (Denmark)

    Iversen, P; Kjaer, L; Thomsen, C

    1988-01-01

    Magnetic resonance imaging offers new possibilities in investigation of the prostate gland. Current results of imaging and tissue discrimination in the evaluation of prostatic disease are reviewed. Magnetic resonance imaging may be useful in the staging of carcinoma of the prostate....

  17. Magnetic resonance imaging of the prostate

    DEFF Research Database (Denmark)

    Iversen, P; Kjaer, L; Thomsen, C

    1987-01-01

    Magnetic resonance imaging offers new possibilities in the investigation of the prostate. The current results of imaging and tissue discrimination in the evaluation of prostatic disease are reviewed. Magnetic resonance imaging may be of value in the staging of carcinoma of the prostate....

  18. Your Radiologist Explains Magnetic Resonance Angiography (MRA)

    Medline Plus

    Full Text Available ... Sponsored by Image/Video Gallery Your Radiologist Explains Magnetic Resonance Angiography (MRA) Transcript Welcome to Radiology Info dot org ... I’d like to talk with you about magnetic resonance angiography, or as it’s commonly known, MRA. MRA is ...

  19. Your Radiologist Explains Magnetic Resonance Angiography (MRA)

    Science.gov (United States)

    ... Sponsored by Image/Video Gallery Your Radiologist Explains Magnetic Resonance Angiography (MRA) Transcript Welcome to Radiology Info dot org ... I’d like to talk with you about magnetic resonance angiography, or as it’s commonly known, MRA. MRA is ...

  20. Functional Magnetic Resonance Imaging and Pediatric Anxiety

    Science.gov (United States)

    Pine, Daniel S.; Guyer, Amanda E.; Leibenluft, Ellen; Peterson, Bradley S.; Gerber, Andrew

    2008-01-01

    The use of functional magnetic resonance imaging in investigating pediatric anxiety disorders is studied. Functional magnetic resonance imaging can be utilized in demonstrating parallels between the neural architecture of difference in anxiety of humans and the neural architecture of attention-orienting behavior in nonhuman primates or rodents.…

  1. resonant inverter supplied interior permanent magnet (ipm)

    African Journals Online (AJOL)

    user

    ABSTRACT. In this paper, rotor position in relation to the resonant frequency component current in the stator winding of DC-voltage link resonant inverter supplied Interior Permanent Magnet. (IPM) motor has been developed. Six reference frames are used to relate the rotor position angle to the resonant frequency ...

  2. Multidimensionally encoded magnetic resonance imaging.

    Science.gov (United States)

    Lin, Fa-Hsuan

    2013-07-01

    Magnetic resonance imaging (MRI) typically achieves spatial encoding by measuring the projection of a q-dimensional object over q-dimensional spatial bases created by linear spatial encoding magnetic fields (SEMs). Recently, imaging strategies using nonlinear SEMs have demonstrated potential advantages for reconstructing images with higher spatiotemporal resolution and reducing peripheral nerve stimulation. In practice, nonlinear SEMs and linear SEMs can be used jointly to further improve the image reconstruction performance. Here, we propose the multidimensionally encoded (MDE) MRI to map a q-dimensional object onto a p-dimensional encoding space where p > q. MDE MRI is a theoretical framework linking imaging strategies using linear and nonlinear SEMs. Using a system of eight surface SEM coils with an eight-channel radiofrequency coil array, we demonstrate the five-dimensional MDE MRI for a two-dimensional object as a further generalization of PatLoc imaging and O-space imaging. We also present a method of optimizing spatial bases in MDE MRI. Results show that MDE MRI with a higher dimensional encoding space can reconstruct images more efficiently and with a smaller reconstruction error when the k-space sampling distribution and the number of samples are controlled. Copyright © 2012 Wiley Periodicals, Inc.

  3. Nuclear Magnetic Resonance imaging; Resonance magnetique nucleaire

    Energy Technology Data Exchange (ETDEWEB)

    Thibierge, M.; Sevestre, L.; Slupecki, P. [Centre Hospitalier de Charleville-Mezieres, 08 (France)

    1998-06-01

    After many years of low profile business in the USA, MRI is back. Improvements are focused on high field magnets and on low field magnets. The former, are dedicated to high quality imaging. The new scanners are more and more efficient because of the spreading use of real time imaging. They can do now, procedures that just could not be imagined some years ago. Vascular imaging is done routinely. Abdominal imaging in apnea of EPI, perfusion and diffusion imaging, and, last not least, all the field of functional imaging are on the verge of coming out. The new magnets unveiled in 1997 are lighter, smaller, more, user friendly, less impressive for patients subject to claustrophobia. They also need less helium to operate and less space to be sited. The latter, are dedicated to interventional procedures. The new magnets are wide opened and a lot of companies show off. Though Picker unveiled a new light superconductive 0.5 Tesla magnet, it seems that this kind of machines are about to disappear. No significant progress was noticed in the field of dedicated MRI devices. Some features can be highlighted: the new Siemens short bore and its table integrates the Panoramic Array Coil Concept. It will allow simultaneous scanning with up to four coils; the excellent homogeneity of the new Picker magnet that will allow spectroscopy at 1 Tesla; the twin gradients of the Elscint Prisma that will open the field of microscopy MRI; the Philips `floppy gradients` that could speed up 4 or 6 times, the time needed for imaging; some new sequences sensitive to temperature are studied as WIP; a lot of work is achieved on 3 or 4 Tesla scanners etc. (author)

  4. Magnetic resonance imaging based clinical research in Alzheimer's disease.

    Science.gov (United States)

    Fayed, Nicolás; Modrego, Pedro J; Salinas, Gulillermo Rojas; Gazulla, José

    2012-01-01

    Alzheimer's disease (AD) is the most common cause of dementia in elderly people in western countries. However important goals are unmet in the issue of early diagnosis and the development of new drugs for treatment. Magnetic resonance imaging (MRI) and volumetry of the medial temporal lobe structures are useful tools for diagnosis. Positron emission tomography is one of the most sensitive tests for making an early diagnosis of AD but the cost and limited availability are important caveats for its utilization. The importance of magnetic resonance techniques has increased gradually to the extent that most clinical works based on AD use these techniques as the main aid to diagnosis. However, the accuracy of structural MRI as biomarker of early AD generally reaches an accuracy of 80%, so additional biomarkers should be used to improve predictions. Other structural MRI (diffusion weighted, diffusion-tensor MRI) and functional MRI have also added interesting contribution to the understanding of the pathophysiology of AD. Magnetic resonance spectroscopy has proven useful to monitor progression and response to treatment in AD, as well as a biomarker of early AD in mild cognitive impairment.

  5. Magnetic Resonance Imaging of Bilirubin Encephalopathy: Current Limitations and Future Promise

    Science.gov (United States)

    Wisnowski, Jessica L.; Panigrahy, Ashok; Painter, Michael J.; Watchko, Jon F.

    2014-01-01

    Infants with chronic bilirubin encephalopathy often demonstrate abnormal bilateral, symmetric, high-signal intensity on T2-weighted magnetic resonance imaging of the globus pallidus and subthalamic nucleus, consistent with the neuropathology of kernicterus. Early magnetic resonance imaging of at risk infants, while frequently showing increased T1-signal in these regions, may give false positive findings due to the presence of myelin in these structures. Advanced magnetic resonance imaging including diffusion-weighted imaging, magnetic resonance spectroscopy, and diffusion tensor imaging with tractography may shed new insights into the pathogenesis of bilirubin-induced brain injury and the neural basis of long-term disability in infants and children with chronic bilirubin encephalopathy. PMID:25267277

  6. A Magnetic Resonance Measurement Technique for Rapidly Switched Gradient Magnetic Fields in a Magnetic Resonance Tomograph

    Directory of Open Access Journals (Sweden)

    K. Bartušek

    2003-01-01

    Full Text Available This paper describes a method for measuring of the gradient magnetic field in Nuclear Magnetic Resonance (NMR tomography, which is one of the modern medical diagnostic methods. A very important prerequisite for high quality imaging is a gradient magnetic field in the instrument with exactly defined properties. Nuclear magnetic resonance enables us to measure the pulse gradient magnetic field characteristics with high accuracy. These interesting precise methods were designed, realised, and tested at the Institute of Scientific Instruments (ISI of the Academy of Sciences of the Czech Republic. The first of them was the Instantaneous Frequency (IF method, which was developed into the Instantaneous Frequency of Spin Echo (IFSE and the Instantaneous Frequency of Spin Echo Series (IFSES methods. The above named methods are described in this paper and their a comparison is also presented.

  7. Magnetic resonance image guided brachytherapy.

    Science.gov (United States)

    Tanderup, Kari; Viswanathan, Akila N; Kirisits, Christian; Frank, Steven J

    2014-07-01

    The application of magnetic resonance image (MRI)-guided brachytherapy has demonstrated significant growth during the past 2 decades. Clinical improvements in cervix cancer outcomes have been linked to the application of repeated MRI for identification of residual tumor volumes during radiotherapy. This has changed clinical practice in the direction of individualized dose administration, and resulted in mounting evidence of improved clinical outcome regarding local control, overall survival as well as morbidity. MRI-guided prostate high-dose-rate and low-dose-rate brachytherapies have improved the accuracy of target and organs-at-risk delineation, and the potential exists for improved dose prescription and reporting for the prostate gland and organs at risk. Furthermore, MRI-guided prostate brachytherapy has significant potential to identify prostate subvolumes and dominant lesions to allow for dose administration reflecting the differential risk of recurrence. MRI-guided brachytherapy involves advanced imaging, target concepts, and dose planning. The key issue for safe dissemination and implementation of high-quality MRI-guided brachytherapy is establishment of qualified multidisciplinary teams and strategies for training and education. Copyright © 2014 Elsevier Inc. All rights reserved.

  8. Microscopic FMR Using Magnetic Resonance Force Microscopy

    Science.gov (United States)

    Zhang, Z.; Hammel, P. C.; Wigen, P. E.

    1996-03-01

    Magnetic resonance force microscopy (MRFM) is a new 3-D imaging technique with ultra-high spatial resolution. This technique, discussed primarily in the context of nuclear magnetic resonance, can also be applied as a microscopic ferromagnetic resonance probe to investigate the distributions of magnetic anisotropy and magnetic exchange interactions within magnetic materials (for example, magnetic multilayer systems). We report the first MRFM experiment on a single crystal Yittrium Iron Garnet film. A non-resonance mode and a family of magneto-static modes were observed in the MRFM spectra. The non-resonance mode is due to the response of the sample magnetization to the applied, time dependent bias field. This will be the main noise source when a magnet is mounted on the cantilever, an arrangement which is necessary in order to perform 3-D imaging in MRFM. The behavior of the magneto-static modes is in qualitative accord with theoretical expectations. The MRFM signal intensity is so large that the experiment is performed under ambient pressure instead of vacuum to reduce the response of the detector (cantilever). This indicates that MRFM will allow micron or sub-micron spatial resolution in studies of a wide variety of magnetic materials.

  9. Magnetic resonance temporal diffusion tensor spectroscopy of disordered anisotropic tissue

    DEFF Research Database (Denmark)

    Nielsen, Jonathan Scharff; Dyrby, Tim B; Lundell, Henrik

    2018-01-01

    Molecular diffusion measured with diffusion weighted MRI (DWI) offers a probe for tissue microstructure. However, inferring microstructural properties from conventional DWI data is a complex inverse problem and has to account for heterogeneity in sizes, shapes and orientations of the tissue compa...

  10. Reducing Field Distortion in Magnetic Resonance Imaging

    Science.gov (United States)

    Eom, Byeong Ho; Penanen, Konstantin; Hahn, Inseob

    2010-01-01

    A concept for a magnetic resonance imaging (MRI) system that would utilize a relatively weak magnetic field provides for several design features that differ significantly from the corresponding features of conventional MRI systems. Notable among these features are a magnetic-field configuration that reduces (relative to the conventional configuration) distortion and blurring of the image, the use of a superconducting quantum interference device (SQUID) magnetometer as the detector, and an imaging procedure suited for the unconventional field configuration and sensor. In a typical application of MRI, a radio-frequency pulse is used to excite precession of the magnetic moments of protons in an applied magnetic field, and the decaying precession is detected for a short time following the pulse. The precession occurs at a resonance frequency proportional to the strengths of the magnetic field and the proton magnetic moment. The magnetic field is configured to vary with position in a known way; hence, by virtue of the aforesaid proportionality, the resonance frequency varies with position in a known way. In other words, position is encoded as resonance frequency. MRI using magnetic fields weaker than those of conventional MRI offers several advantages, including cheaper and smaller equipment, greater compatibility with metallic objects, and higher image quality because of low susceptibility distortion and enhanced spin-lattice-relaxation- time contrast. SQUID MRI is being developed into a practical MRI method for applied magnetic flux densities of the order of only 100 T

  11. Your Radiologist Explains Magnetic Resonance Angiography (MRA)

    Medline Plus

    Full Text Available ... Imaging Costs Video: Abdominal Ultrasound Video: Pelvic Ultrasound Radiology and You Sponsored by Image/Video Gallery Your ... Explains Magnetic Resonance Angiography (MRA) Transcript Welcome to Radiology Info dot org Hello, I’m Dr. Elliot ...

  12. Your Radiologist Explains Magnetic Resonance Angiography (MRA)

    Medline Plus

    Full Text Available ... Lung Cancer Awareness Month Recently posted: Carotid Intima-Media Thickness Test Medical Imaging Costs Video: Abdominal Ultrasound Video: Pelvic Ultrasound Radiology and You Sponsored by Image/Video Gallery Your Radiologist Explains Magnetic Resonance Angiography ( ...

  13. single voxel magnetic resonance spectroscopy in distinguishing

    African Journals Online (AJOL)

    2011-03-03

    Mar 3, 2011 ... magnetic resonance spectroscopy (MRI, MRS) in differentiating focal neoplastic lesions from focal non- neoplastic (infective or degenerative) brain lesions. Design: Descriptive, analytical - prospective study. Setting: The Aga Khan University MRI department. Subject: Seventy four consecutive patients.

  14. Review of cardiovascular magnetic resonance in human ...

    African Journals Online (AJOL)

    In recent times, cardiovascular magnetic resonance (CMR) imaging has emerged as the gold standard tool for assessment of a variety of indications, allowing comprehensive characterisation of functional, morphological, metabolic and haemodynamic sequelae of several cardiovascular pathologies. Furthermore, continued ...

  15. The role of magnetic resonance cholangiopancreatography and ...

    African Journals Online (AJOL)

    ) is accepted as the gold standard, there is a place for magnetic resonance cholangiopancreatography (MRCP) and diffusion-weighted imaging (DWI) in the diagnosis of obstructive biliary disorders. Aim: To compare the findings of MRCP with ...

  16. Your Radiologist Explains Magnetic Resonance Angiography (MRA)

    Medline Plus

    Full Text Available ... Video: Pelvic Ultrasound Radiology and You Sponsored by Image/Video Gallery Your Radiologist Explains Magnetic Resonance Angiography ( ... pictures of the major blood vessels throughout your body. It may be performed with or without contrast ...

  17. Your Radiologist Explains Magnetic Resonance Angiography (MRA)

    Medline Plus

    Full Text Available ... Dr. Elliot Fishman, a radiologist at Johns Hopkins Hospital in Baltimore, Maryland. I’d like to talk with you about magnetic resonance angiography, or as it’s commonly known, MRA. ...

  18. Your Radiologist Explains Magnetic Resonance Angiography (MRA)

    Medline Plus

    Full Text Available ... with you about magnetic resonance angiography, or as it’s commonly known, MRA. MRA is a noninvasive test ... of the major blood vessels throughout your body. It may be performed with or without contrast material ...

  19. Your Radiologist Explains Magnetic Resonance Angiography (MRA)

    Medline Plus

    Full Text Available ... mild sedative prior to the examination. For more information about Magnetic Resonance Angiography of MRA or any ... Inc. (RSNA). To help ensure current and accurate information, we do not permit copying but encourage linking ...

  20. Magnetic Resonance Spectroscopy of Breast Disease

    National Research Council Canada - National Science Library

    Ikeda, Debra

    2001-01-01

    We have developed a unique magnetic resonance imaging multi voxel pulse sequence producing spectroscopic images of key metabolites found in breast cancer, and validated our work with in vitro spectra and pathology...

  1. Your Radiologist Explains Magnetic Resonance Angiography (MRA)

    Medline Plus

    Full Text Available ... and You Take our survey Sponsored by Image/Video Gallery Your Radiologist Explains Magnetic Resonance Angiography (MRA) ... Carotid Intima-Media Thickness Test Medical Imaging Costs Video: Abdominal Ultrasound Video: Pelvic Ultrasound Radiology and You ...

  2. Your Radiologist Explains Magnetic Resonance Angiography (MRA)

    Medline Plus

    Full Text Available ... Index A-Z Spotlight Recently posted: Carotid Intima-Media Thickness Test Medical Imaging Costs Video: Abdominal Ultrasound Video: Pelvic Ultrasound Radiology and You Sponsored by Image/Video Gallery Your Radiologist Explains Magnetic Resonance Angiography ( ...

  3. Your Radiologist Explains Magnetic Resonance Angiography (MRA)

    Medline Plus

    Full Text Available ... of Radiology (IDoR) Radiology and You Sponsored by Image/Video Gallery Your Radiologist Explains Magnetic Resonance Angiography ( ... pictures of the major blood vessels throughout your body. It may be performed with or without contrast ...

  4. Magnetic resonance force microscopy using ferromagnetic resonance of a magnetic tip excited by microwave transmission via a coaxial resonator

    Science.gov (United States)

    Kinoshita, Yukinori; Li, Yan Jun; Yoshimura, Satoru; Saito, Hitoshi; Sugawara, Yasuhiro

    2017-12-01

    The present work proposes magnetic resonance force microscopy (MRFM) based on ferromagnetic resonance (FMR) modulation of a magnetic tip using microwave transmission via a coaxial resonator instead of using conventional microwave irradiation by an external antenna. In this MRFM, the coaxial resonator is electrically connected to the magnetic cantilever tip, which enables simple implementation of FMR excitation of a magnetic tip in conventional magnetic force microscopy. The FMR frequency of the tip can be easily extracted from the reflection spectrum of a transmission line connected to the magnetic tip. The excitation of tip FMR is confirmed from the microwave frequency dependence of the mechanical response of the tip oscillation. This MRFM is effective for extracting the magnetic interaction force near a sample surface without perturbation of its magnetic state. Nanometer-scale imaging of magnetic domain structures on a demagnetized thin-film permanent magnet is successfully demonstrated.

  5. Can magnetic resonance imaging differentiate undifferentiated arthritis?

    DEFF Research Database (Denmark)

    Østergaard, Mikkel; Duer, Anne; Hørslev-Petersen, K

    2005-01-01

    A high sensitivity for the detection of inflammatory and destructive changes in inflammatory joint diseases makes magnetic resonance imaging potentially useful for assigning specific diagnoses, such as rheumatoid arthritis and psoriatic arthritis in arthritides, that remain undifferentiated after...... conventional clinical, biochemical and radiographic examinations. With recent data as the starting point, the present paper describes the current knowledge on magnetic resonance imaging in the differential diagnosis of undifferentiated arthritis....

  6. Nuclear Magnetic Resonance Imaging: Current Capabilities

    OpenAIRE

    Davis, Peter L.; Crooks, Lawrence E.; Margulis, Alexander R.; Kaufman, Leon

    1982-01-01

    Nuclear magnetic resonance imaging can produce tomographic images of the body without ionizing radiation. Images of the head, chest, abdomen, pelvis and extremities have been obtained and normal structures and pathology have been identified. Soft tissue contrast with this method is superior to that with x-ray computerized tomography and its spatial resolution is approaching that of x-ray computerized tomography. In addition, nuclear magnetic resonance imaging enables us to image along the sag...

  7. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... flow to the heart muscle evaluate findings following cardiovascular surgery In the abdominal and pelvic region, MRI ... the magnet. Some MRI units, called short-bore systems , are designed so that the magnet does not ...

  8. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... a powerful magnetic field, radio waves and a computer to produce detailed pictures of the inside of ... powerful magnetic field, radio frequency pulses and a computer to produce detailed pictures of organs, soft tissues, ...

  9. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... a powerful magnetic field, radio waves and a computer to produce detailed pictures of the brain and ... powerful magnetic field, radio frequency pulses and a computer to produce detailed pictures of organs, soft tissues, ...

  10. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... MRI) of the head uses a powerful magnetic field, radio waves and a computer to produce detailed ... there’s a possibility you are pregnant. The magnetic field is not harmful, but it may cause some ...

  11. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... help detect certain chronic diseases of the nervous system, such as multiple sclerosis diagnose problems with the ... the magnet. Some MRI units, called short-bore systems , are designed so that the magnet does not ...

  12. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... their nature and the strength of the MRI magnet. Many implanted devices will have a pamphlet explaining ... large cylinder-shaped tube surrounded by a circular magnet. You will lie on a moveable examination table ...

  13. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... their nature and the strength of the MRI magnet. Many implanted devices will have a pamphlet explaining ... large cylinder-shaped tube surrounded by a circular magnet. Your child will lie on a moveable examination ...

  14. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... ports artificial limbs or metallic joint prostheses implanted nerve stimulators metal pins, screws, plates, stents or surgical ... the magnet. Some MRI units, called short-bore systems , are designed so that the magnet does not ...

  15. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... of the head uses a powerful magnetic field, radio waves and a computer to produce detailed pictures ... medical conditions. MRI uses a powerful magnetic field, radio frequency pulses and a computer to produce detailed ...

  16. Magnetic resonance force detection using a membrane resonator.

    Science.gov (United States)

    Scozzaro, N; Ruchotzke, W; Belding, A; Cardellino, J; Blomberg, E C; McCullian, B A; Bhallamudi, V P; Pelekhov, D V; Hammel, P C

    2016-10-01

    The availability of compact, low-cost magnetic resonance imaging instruments would further broaden the substantial impact of this technology. We report highly sensitive detection of magnetic resonance using low-stress silicon nitride (SiNx) membranes. We use these membranes as low-loss, high-frequency mechanical oscillators and find they are able to mechanically detect spin-dependent forces with high sensitivity enabling ultrasensitive magnetic resonance detection. The high force detection sensitivity stems from their high mechanical quality factor Q∼10(6)[1,2] combined with the low mass of the resonator. We use this excellent mechanical force sensitivity to detect the electron spin magnetic resonance using a SiNx membrane as a force detector. The demonstrated force sensitivity at 300K is 4fN/Hz, indicating a potential low temperature (4K) sensitivity of 25aN/Hz. Given their sensitivity, robust construction, large surface area and low cost, SiNx membranes can potentially serve as the central component of a compact room-temperature ESR and NMR instrument having spatial resolution superior to conventional approaches. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. Magnetic resonance imaging for diagnosis of early Alzheimer's disease.

    Science.gov (United States)

    Colliot, O; Hamelin, L; Sarazin, M

    2013-10-01

    A major challenge for neuroimaging is to contribute to the early diagnosis of Alzheimer's disease (AD). In particular, magnetic resonance imaging (MRI) allows detecting different types of structural and functional abnormalities at an early stage of the disease. Anatomical MRI is the most widely used technique and provides local and global measures of atrophy. The recent diagnostic criteria of "mild cognitive impairment due to AD" include hippocampal atrophy, which is considered a marker of neuronal injury. Advanced image analysis techniques generate automatic and reproducible measures both in the hippocampus and throughout the whole brain. Recent modalities such as diffusion-tensor imaging and resting-state functional MRI provide additional measures that could contribute to the early diagnosis but require further validation. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  18. Magnetic nanoparticles in magnetic resonance imaging and diagnostics.

    Science.gov (United States)

    Rümenapp, Christine; Gleich, Bernhard; Haase, Axel

    2012-05-01

    Magnetic nanoparticles are useful as contrast agents for magnetic resonance imaging (MRI). Paramagnetic contrast agents have been used for a long time, but more recently superparamagnetic iron oxide nanoparticles (SPIOs) have been discovered to influence MRI contrast as well. In contrast to paramagnetic contrast agents, SPIOs can be functionalized and size-tailored in order to adapt to various kinds of soft tissues. Although both types of contrast agents have a inducible magnetization, their mechanisms of influence on spin-spin and spin-lattice relaxation of protons are different. A special emphasis on the basic magnetism of nanoparticles and their structures as well as on the principle of nuclear magnetic resonance is made. Examples of different contrast-enhanced magnetic resonance images are given. The potential use of magnetic nanoparticles as diagnostic tracers is explored. Additionally, SPIOs can be used in diagnostic magnetic resonance, since the spin relaxation time of water protons differs, whether magnetic nanoparticles are bound to a target or not.

  19. Coherence of magnetic resonators in a metamaterial

    Directory of Open Access Journals (Sweden)

    Yumin Hou

    2013-12-01

    Full Text Available The coherence of periodic magnetic resonators (MRs under oblique incidence is studied using simulations. The correlated phase of interaction including both the retardation effect and relative phase difference between two MRs is defined, and it plays a key role in the MR interaction. The correlated phase is anisotropic, as is the coherence condition. The coherence condition is the same as the Wood's anomaly and verified by the Fano resonance. This study shows that the applications of the Fano resonance of periodic MRs will become widespread owing to achieving the Fano resonance simply by tuning the incident angle.

  20. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... imaging (MRI) of the head uses a powerful magnetic field, radio waves and a computer to produce detailed ... whether there’s a possibility you are pregnant. The magnetic field is not harmful, but it may cause some ...

  1. Magnetic material arrangement in oriented termites: a magnetic resonance study

    Science.gov (United States)

    Alves, O. C.; Wajnberg, E.; de Oliveira, J. F.; Esquivel, D. M. S.

    2004-06-01

    Temperature dependence of the magnetic resonance is used to study the magnetic material in oriented Neocapritermes opacus (N.o.) termite, the only prey of the migratory ant Pachycondyla marginata (P.m.). A broad line in the g=2 region, associated to isolated nanoparticles shows that at least 97% of the magnetic material is in the termite's body (abdomen + thorax). From the temperature dependence of the resonant field and from the spectral linewidths, we estimate the existence of magnetic nanoparticles 18.5 ± 0.3 nm in diameter and an effective magnetic anisotropy constant, Keff between 2.1 and 3.2 × 10 4 erg/cm 3. A sudden change in the double integrated spectra at about 100 K for N.o. with the long body axis oriented perpendicular to the magnetic field can be attributed to the Verwey transition, and suggests an organized film-like particle system.

  2. Magnetic resonance elastography: Inversions in bounded media.

    Science.gov (United States)

    Kolipaka, Arunark; McGee, Kiaran P; Manduca, Armando; Romano, Anthony J; Glaser, Kevin J; Araoz, Philip A; Ehman, Richard L

    2009-12-01

    Magnetic resonance elastography is a noninvasive imaging technique capable of quantifying and spatially resolving the shear stiffness of soft tissues by visualization of synchronized mechanical wave displacement fields. However, magnetic resonance elastography inversions generally assume that the measured tissue motion consists primarily of shear waves propagating in a uniform, infinite medium. This assumption is not valid in organs such as the heart, eye, bladder, skin, fascia, bone and spinal cord, in which the shear wavelength approaches the geometric dimensions of the object. The aim of this study was to develop and test mathematical inversion algorithms capable of resolving shear stiffness from displacement maps of flexural waves propagating in bounded media such as beams, plates, and spherical shells, using geometry-specific equations of motion. Magnetic resonance elastography and finite element modeling of beam, plate, and spherical shell phantoms of various geometries were performed. Mechanical testing of the phantoms agreed with the stiffness values obtained from finite element modeling and magnetic resonance elastography data, and a linear correlation of r(2) >or= 0.99 was observed between the stiffness values obtained using magnetic resonance elastography and finite element modeling data. In conclusion, we have demonstrated new inversion methods for calculating shear stiffness that may be more appropriate for waves propagating in bounded media. (c) 2009 Wiley-Liss, Inc.

  3. Magnetic resonance imaging by using nano-magnetic particles

    Science.gov (United States)

    Shokrollahi, H.; Khorramdin, A.; Isapour, Gh.

    2014-11-01

    Magnetism and magnetic materials play a major role in various biological applications, such as magnetic bioseparation, magnetic resonance imaging (MRI), hyperthermia treatment of cancer and drug delivery. Among these techniques, MRI is a powerful method not only for diagnostic radiology but also for therapeutic medicine that utilizes a magnetic field and radio waves. Recently, this technique has contributed greatly to the promotion of the human quality life. Thus, this paper presents a short review of the physical principles and recent advances of MRI, as well as providing a summary of the synthesis methods and properties of contrast agents, like different core materials and surfactants.

  4. Magnetic resonance signal moment determination using the Earth's magnetic field

    KAUST Repository

    Fridjonsson, Einar Orn

    2015-03-01

    We demonstrate a method to manipulate magnetic resonance data such that the moments of the signal spatial distribution are readily accessible. Usually, magnetic resonance imaging relies on data acquired in so-called k-space which is subsequently Fourier transformed to render an image. Here, via analysis of the complex signal in the vicinity of the centre of k-space we are able to access the first three moments of the signal spatial distribution, ultimately in multiple directions. This is demonstrated for biofouling of a reverse osmosis (RO) membrane module, rendering unique information and an early warning of the onset of fouling. The analysis is particularly applicable for the use of mobile magnetic resonance spectrometers; here we demonstrate it using an Earth\\'s magnetic field system.

  5. Classification of metallic targets using a single frequency component of the magnetic polarisability tensor

    Science.gov (United States)

    Makkonen, J.; Marsh, L. A.; Vihonen, J.; Visa, A.; Järvi, A.; Peyton, A. J.

    2013-06-01

    A k-nearest neighbour (KNN) classification algorithm has been added to a walk-through metal detection system which is capable of inverting the magnetic polarisability tensor of metallic targets at a frequency of 10 kHz. Pre-computed library data is used to determine the class of the object, e.g. 'knife' or 'mobile phone', and is consequently capable of determining if an object is considered a threat. The results presented show a typical success rate of 95%. An investigation into classification accuracy between different candidates is also presented to determine the significance of the body effect on the success of the classification.

  6. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... MRI. If you have a history of kidney disease or liver transplant, it will be necessary to perform a blood test to determine whether the kidneys are functioning adequately. Women ... Images related to Magnetic ...

  7. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... doctor about your child’s health problems, medications, recent surgeries and allergies. The magnetic field is not harmful, ... to the heart muscle evaluate findings following cardiovascular surgery In the abdominal and pelvic region, MRI is ...

  8. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... scanner. top of page How does the procedure work? Unlike conventional x-ray examinations and computed tomography ( ... also screened for safety in the magnetic environment. Children will be given appropriately sized earplugs or headphones ...

  9. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... magnetic field of the MRI unit, metal and electronic items are not allowed in the exam room. ... tell the technologist if you have medical or electronic devices in your body. These objects may interfere ...

  10. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... if your child has any implanted medical or electronic devices. Inform your doctor and the technologist prior ... magnetic field of the MRI unit, metal and electronic items are not allowed in the exam room. ...

  11. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... variety of conditions within the brain, chest, abdomen, pelvis and extremities. Tell your doctor about your child’s health problems, medications, recent surgeries and allergies. The magnetic field is ...

  12. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... pregnant. The magnetic field is not harmful, but it may cause some medical devices to malfunction. Most ... number of abrupt onset or long-standing symptoms. It can help diagnose conditions such as: brain tumors ...

  13. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... allergies. The magnetic field is not harmful, but it may cause some medical devices to malfunction. Most ... cord is needed, MRI is useful because of its ability to see through the skull and the ...

  14. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... extremities. Tell your doctor about your child’s health problems, medications, recent surgeries and allergies. The magnetic field ... and abnormalities like cysts, tumors, bleeding, swelling, or problems with the blood vessels detect damage to the ...

  15. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... The magnetic field is produced by passing an electric current through wire coils in most MRI units. Other coils, located in the machine and in some cases, placed around the part ...

  16. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... The magnetic field is produced by passing an electric current through wire coils in most MRI units. Other coils, located in the machine and in some cases, placed around the part ...

  17. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... traditional MRI unit is a large cylinder-shaped tube surrounded by a circular magnet. You will lie ... your skin at the site of the IV tube insertion. Some patients may sense a temporary metallic ...

  18. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... The magnetic field is produced by passing an electric current through wire coils in most MRI units. ... signals that are detected by the coils. The electric current does not come in contact with the ...

  19. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... The magnetic field is produced by passing an electric current through wire coils in most MRI units. ... signals that are detected by the coils. The electric current does not come in contact with the ...

  20. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... of the inside of your child’s body. MRI may be used to help diagnose or monitor treatment ... The magnetic field is not harmful, but it may cause some medical devices to malfunction. Most orthopedic ...

  1. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... This exam does not use ionizing radiation and may require an injection of a contrast material called ... The magnetic field is not harmful, but it may cause some medical devices to malfunction. Most orthopedic ...

  2. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... interfere with the magnetic field of the MRI unit, metal and electronic items are not allowed in ... the MRI equipment look like? The traditional MRI unit is a large cylinder-shaped tube surrounded by ...

  3. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... interfere with the magnetic field of the MRI unit, metal and electronic items are not allowed in ... does the equipment look like? The traditional MRI unit is a large cylinder-shaped tube surrounded by ...

  4. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... they may move during the scan, possibly causing blindness. Dyes used in tattoos may contain iron and ... also screened for safety in the magnetic environment. Children will be given appropriately sized earplugs or headphones ...

  5. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... also screened for safety in the magnetic environment. Children will be given appropriately sized earplugs or headphones ... have special pediatric considerations. The teddy bear denotes child-specific content. Related Articles and Media MR Angiography ( ...

  6. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... x-ray contrast material, drugs, food, or the environment, or if you have asthma. The contrast material ... are also screened for safety in the magnetic environment. Children will be given appropriately sized earplugs or ...

  7. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... x-ray contrast material, drugs, food, or the environment, or if your child has asthma. The contrast ... are also screened for safety in the magnetic environment. Children will be given appropriately sized earplugs or ...

  8. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... detail makes MRI an invaluable tool in early diagnosis and evaluation of many conditions, including tumors. MRI ... the technologist or nurse will monitor your vital signs to minimize this risk. Although the strong magnetic ...

  9. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... detail makes MRI an invaluable tool in early diagnosis and evaluation of many focal lesions and tumors ... the technologist or nurse monitors your child’s vital signs to minimize this risk. Although the strong magnetic ...

  10. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... your child’s health problems, medications, recent surgeries and allergies. The magnetic field is not harmful, but it ... the exam if your child has a known allergy to contrast material. Your child should wear loose, ...

  11. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... magnetic field is not harmful, but it may cause some medical devices to malfunction. Most orthopedic implants ... with the pituitary gland and brainstem assess the cause of developmental delay identify and evaluate degenerated or ...

  12. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... material called gadolinium, which is less likely to cause an allergic reaction than iodinated contrast material. Tell ... magnetic field is not harmful, but it may cause some medical devices to malfunction. Most orthopedic implants ...

  13. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... scanner. top of page How does the procedure work? Unlike conventional x-ray examinations and computed tomography ( ... as long as they are also screened for safety in the magnetic environment. Children will be given ...

  14. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... scanner. top of page How does the procedure work? Unlike conventional x-ray examinations and computed tomography ( ... as long as they are also screened for safety in the magnetic environment. Children will be given ...

  15. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... the head uses a powerful magnetic field, radio waves and a computer to produce detailed pictures of ... the body being imaged, send and receive radio waves, producing signals that are detected by the coils. ...

  16. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... imaging (MRI) uses a powerful magnetic field, radio waves and a computer to produce detailed pictures of ... the body being imaged, send and receive radio waves, producing signals that are detected by the coils. ...

  17. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... and extremities. Tell your doctor about your child’s health problems, medications, recent surgeries and allergies. The magnetic ... the radiologist if your child has any serious health problems or has recently had surgery. Some conditions, ...

  18. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... with no reports of any ill effects on pregnant women or their unborn babies. However, because the unborn baby will be in a strong magnetic field, pregnant women should not have this exam in the first ...

  19. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... scanner. top of page How does the procedure work? Unlike conventional x-ray examinations and computed tomography ( ... are also screened for safety in the magnetic environment. Children will be given appropriately sized earplugs or ...

  20. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... scanner. top of page How does the procedure work? Unlike conventional x-ray examinations and computed tomography ( ... are also screened for safety in the magnetic environment. Children will be given appropriately sized earplugs or ...

  1. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... if possible, or removed prior to the MRI scan. Because they can interfere with the magnetic field ... particularly important because they may move during the scan, possibly causing blindness. Dyes used in tattoos may ...

  2. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... unborn baby will be in a strong magnetic field, pregnant women should not have this exam in the first three to four months of pregnancy unless the potential benefit from the MRI exam is assumed to ...

  3. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... and send a signed report to your primary care or referring physician, who will share the results ... magnetic field is not harmful in itself, implanted medical devices that contain metal may malfunction or cause ...

  4. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... and send a signed report to your primary care or referring physician, who will share the results ... magnetic field is not harmful in itself, implanted medical devices that contain metal may malfunction or cause ...

  5. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... a large cylinder-shaped tube surrounded by a circular magnet. You will lie on a moveable examination ... at a very early stage by mapping the motion of water molecules in the tissue. This water ...

  6. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... the radiofrequency pulses are activated. Some centers provide earplugs, while others use headphones to reduce the intensity ... magnetic environment. Children will be given appropriately sized earplugs or headphones during the exam. MRI scanners are ...

  7. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... conditions. MRI uses a powerful magnetic field, radio frequency pulses and a computer to produce detailed pictures ... does not completely surround you. Some newer MRI machines have a larger diameter bore which can be ...

  8. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... conditions. MRI uses a powerful magnetic field, radio frequency pulses and a computer to produce detailed pictures ... does not completely surround you. Some newer MRI machines have a larger diameter bore which can be ...

  9. MAGNETIC RESONANCE SEMIOTICS OF BREAST CANCER

    Directory of Open Access Journals (Sweden)

    S. V. Serebryakova

    2009-01-01

    Full Text Available Breast cancer (BC that is the most common malignancy in women presents an indubitable threat to their life and health. The basis for this investigation was magnetic resonance imaging (MRI data of 203 women with histologically verified malignan- cies. The patients' mean age was 53±10.2 years. The paper describes the magnetic resonance semiotics of BC; the authors have developed criteria for dynamic contrast-enhanced magnetic resonance mammography used in the differential diagnosis of nodules.Due to high soft-tissue contrast, the use of thin sections, and the possibility of examining in any projection, MRI allows one not only to accurately visualize a pathological mass as compared with X-ray mammography or ultrasound study, but also to characterize its vascularization, which is a major criteria for the differential diagnosis of benign and malignant breast nodules.

  10. Magnetic resonance enterography in pediatric celiac disease.

    Science.gov (United States)

    Koc, Gonca; Doganay, Selim; Sevinc, Eylem; Deniz, Kemal; Chavhan, Govind; Gorkem, Sureyya B; Karacabey, Neslihan; Dogan, Mehmet S; Coskun, Abdulhakim; Aslan, Duran

    To assess if magnetic resonance enterography is capable of showing evidence/extent of disease in pediatric patients with biopsy-proven celiac disease by comparing with a control group, and to correlate the magnetic resonance enterography findings with anti-endomysial antibody level, which is an indicator of gluten-free dietary compliance. Thirty-one pediatric patients (mean age 11.7±3.1 years) with biopsy-proven celiac disease and 40 pediatric patients as a control group were recruited in the study. The magnetic resonance enterography images of both patients with celiac disease and those of the control group were evaluated by two pediatric radiologists in a blinded manner for the mucosal pattern, presence of wall thickening, luminal distention of the small bowel, and extra-intestinal findings. Patient charts were reviewed to note clinical features and laboratory findings. The histopathologic review of the duodenal biopsies was re-conducted. The mean duration of the disease was 5.6±1.8 years (range: 3-7.2 years). In 24 (77%) of the patients, anti-endomysial antibody levels were elevated (mean 119.2±66.6RU/mL). Magnetic resonance enterography revealed normal fold pattern in all the patients. Ten (32%) patients had enlarged mesenteric lymph nodes. Although a majority of the patients had elevated anti-endomysial antibody levels indicating poor dietary compliance, magnetic resonance enterography did not show any mucosal abnormality associated with the inability of magnetic resonance enterography to detect mild/early changes of celiac disease in children. Therefore, it may not be useful for the follow-up of pediatric celiac disease. Copyright © 2017 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  11. Introduction to magnetic resonance methods in photosynthesis

    OpenAIRE

    Huber, Martina

    2009-01-01

    Electron paramagnetic resonance (EPR) and, more recently, solid-state nuclear magnetic resonance (NMR) have been employed to study photosynthetic processes, primarily related to the light-induced charge separation. Information obtained on the electronic structure, the relative orientation of the cofactors, and the changes in structure during these reactions should help to understand the efficiency of light-induced charge separation. A short introduction to the observables derived from magneti...

  12. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... if a finding is stable or changed over time. top of page What are the benefits vs. risks? Benefits MRI is a ... resonance imaging harms the fetus, pregnant women usually are advised not to have an ... take more time to perform than other imaging modalities. top of ...

  13. Magnetic resonance imaging of the pelvic floor: from clinical to biomechanical imaging.

    Science.gov (United States)

    Brandão, Sofia; Da Roza, Thuane; Parente, Marco; Ramos, Isabel; Mascarenhas, Teresa; Natal Jorge, Renato M

    2013-12-01

    This article reviews the current role of magnetic resonance imaging in the study of the pelvic floor anatomy and pelvic floor dysfunction. The application of static and dynamic magnetic resonance imaging in the clinical context and for biomechanical simulation modeling is assessed, and the main findings are summarized. Additionally, magnetic resonance-based diffusion tensor imaging is presented as a potential tool to evaluate muscle fiber morphology. In this article, focus is set on pelvic floor muscle damage related to urinary incontinence and pelvic organ prolapse, sometimes as a consequence of vaginal delivery. Modeling applications that evaluate anatomical and physiological properties of pelvic floor are presented to further illustrate their particular characteristics. Finally, finite element method is described as a method for modeling and analyzing pelvic floor structures' biomechanical performance, based on material and behavioral properties of the tissues, and considering pressure loads that mimic real-life conditions such as active contraction or Valsalva maneuver.

  14. Shape anisotropy: tensor distance to anisotropy measure

    Science.gov (United States)

    Weldeselassie, Yonas T.; El-Hilo, Saba; Atkins, M. S.

    2011-03-01

    Fractional anisotropy, defined as the distance of a diffusion tensor from its closest isotropic tensor, has been extensively studied as quantitative anisotropy measure for diffusion tensor magnetic resonance images (DT-MRI). It has been used to reveal the white matter profile of brain images, as guiding feature for seeding and stopping in fiber tractography and for the diagnosis and assessment of degenerative brain diseases. Despite its extensive use in DT-MRI community, however, not much attention has been given to the mathematical correctness of its derivation from diffusion tensors which is achieved using Euclidean dot product in 9D space. But, recent progress in DT-MRI has shown that the space of diffusion tensors does not form a Euclidean vector space and thus Euclidean dot product is not appropriate for tensors. In this paper, we propose a novel and robust rotationally invariant diffusion anisotropy measure derived using the recently proposed Log-Euclidean and J-divergence tensor distance measures. An interesting finding of our work is that given a diffusion tensor, its closest isotropic tensor is different for different tensor distance metrics used. We demonstrate qualitatively that our new anisotropy measure reveals superior white matter profile of DT-MR brain images and analytically show that it has a higher signal to noise ratio than fractional anisotropy.

  15. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Children’s (Pediatric) Magnetic ... patient to have an allergy to a gadolinium-based contrast agent used for MRI than the iodine- ...

  16. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... come. The MR scanner captures this energy and creates a picture of the tissues scanned based on this information. The magnetic field is produced by passing an electric current through wire coils in most MRI units. Other coils, located in the machine and in some cases, placed around the part ...

  17. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... come. The MR scanner captures this energy and creates a picture of the tissues scanned based on this information. The magnetic field is produced by passing an electric current through wire coils in most MRI units. Other coils, located in the machine and in some cases, placed around the part ...

  18. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... with the magnetic field of the MRI unit, metal and electronic items are not allowed in the exam room. ... into the scanning room also need to remove metal objects and notify the technologist of any medical or electronic devices they may have. If your child has ...

  19. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... with the magnetic field of the MRI unit, metal and electronic items are not allowed in the exam room. ... into the scanning room also need to remove metal objects and notify the technologist of any medical or electronic devices they may have. top of page What ...

  20. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... a powerful magnetic field, radio waves and a computer to produce detailed pictures of the inside of your child’s body. MRI may be used to help diagnose or monitor treatment for a variety of conditions within the brain, chest, abdomen, pelvis and extremities. Tell your doctor ...

  1. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... a powerful magnetic field, radio waves and a computer to produce detailed pictures of the brain and other cranial structures that are clearer and ... The images can then be examined on a computer monitor, transmitted electronically, printed ... in routine clinical practice. top of page What ...

  2. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... ill effects on pregnant women or their unborn babies. However, because the unborn baby will be in a strong magnetic field, pregnant ... intravenous contrast indicate mothers should not breastfeed their babies for 24-48 hours after contrast medium is ...

  3. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... and extremities. Tell your doctor about your child’s health problems, medications, recent surgeries and allergies. The magnetic field is not harmful, but it may cause some medical devices to malfunction. Most orthopedic implants pose no risk, but you should always tell the technologist if ...

  4. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... You may resume your usual activities and normal diet immediately after the exam. On very rare occasions, ... imaging based on the electrical activity of the heart, such as electrocardiography (EKG). MRI generally is not recommended for ... Tumors Images related to Magnetic ...

  5. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... pieces of metal which may be present in your child’s body due to prior accidents. Foreign bodies near and especially lodged in the eyes are particularly important. Tooth fillings and braces usually are not affected by the magnetic field, but they may distort ...

  6. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... the head uses a powerful magnetic field, radio waves and a computer to produce detailed pictures of the brain and other cranial structures that are clearer and more detailed than other imaging methods. This exam does not use ionizing radiation and may require an injection of a ...

  7. Children's (Pediatric) Magnetic Resonance Imaging

    Medline Plus

    Full Text Available ... imaging (MRI) uses a powerful magnetic field, radio waves and a computer to produce detailed pictures of the inside of your child’s body. MRI may be used to help diagnose or monitor treatment for a variety of conditions within the brain, chest, abdomen, pelvis and extremities. Tell your doctor ...

  8. Minimal tensors and purely electric or magnetic spacetimes of arbitrary dimension

    CERN Document Server

    Hervik, Sigbjørn; Wylleman, Lode

    2013-01-01

    We consider time reversal transformations to obtain twofold orthogonal splittings of any tensor on a Lorentzian space of arbitrary dimension n. Applied to the Weyl tensor of a spacetime, this leads to a definition of its electric and magnetic parts relative to an observer (i.e., a unit timelike vector field u), in any n. We study the cases where one of these parts vanishes in particular, i.e., purely electric (PE) or magnetic (PM) spacetimes. We generalize several results from four to higher dimensions and discuss new features of higher dimensions. We prove that the only permitted Weyl types are G, I_i and D, and discuss the possible relation of u with the WANDs; we provide invariant conditions that characterize PE/PM spacetimes, such as Bel-Debever criteria, or constraints on scalar invariants, and connect the PE/PM parts to the kinematic quantities of u; we present conditions under which direct product spacetimes (and certain warps) are PE/PM, which enables us to construct explicit examples. In particular, ...

  9. A hyperpolarized equilibrium for magnetic resonance

    OpenAIRE

    Hövener, Jan-Bernd; Schwaderlapp, Niels; Lickert, Thomas; Duckett, Simon B.; Mewis, Ryan E.; Highton, Louise A. R.; Kenny, Stephen M.; Green, Gary G. R.; Leibfritz, Dieter; Korvink, Jan G.; Hennig, Jürgen; von Elverfeldt, Dominik

    2013-01-01

    Nuclear magnetic resonance spectroscopy and imaging (MRI) play an indispensable role in science and healthcare but use only a tiny fraction of their potential. No more than ≈10 p.p.m. of all 1H nuclei are effectively detected in a 3-Tesla clinical MRI system. Thus, a vast array of new applications lays dormant, awaiting improved sensitivity. Here we demonstrate the continuous polarization of small molecules in solution to a level that cannot be achieved in a viable magnet. The magnetization d...

  10. Your Radiologist Explains Magnetic Resonance Angiography (MRA)

    Medline Plus

    Full Text Available ... problems, recent surgeries and allergies. If you’re female and there’s a possibility that you’re pregnant ... doctor for a mild sedative prior to the examination. For more information about Magnetic Resonance Angiography of MRA or any specific ... Sponsored by About Us | ...

  11. Magnetic resonance imaging in radiotherapy treatment planning

    NARCIS (Netherlands)

    Moerland, Marinus Adriaan

    1996-01-01

    From its inception in the early 1970's up to the present, magnetic resonance imaging (MRI) has evolved into a sophisticated technique, which has aroused considerable interest in var- ious subelds of medicine including radiotherapy. MRI is capable of imaging in any plane and does not use ionizing

  12. Magnetic resonance imaging study of corpus callosum

    African Journals Online (AJOL)

    2014-11-02

    Nov 2, 2014 ... We recruited 58 chronically schizophrenic patients with different subtypes, and 31 age-and-gender matched healthy controls. The callosum was extracted from a midsagittal slice from T1 weighted magnetic resonance images, and areas of the total CC, its five subregions,. CC length and total brain volume ...

  13. ORIGINAL ARTICLE Multimodal magnetic resonance imaging ...

    African Journals Online (AJOL)

    tumours and the peritumoural oedema. Multimodal magnetic resonance imaging increases the overall diagnostic accuracy in brain tumours: Correlation with histopathology. K Abul-Kasim, M Thurnher, S Puchner, P Sundgren. Faculty of Medicine, Lund University, Division of Neuroradiology, Diagnostic Centre for Imaging ...

  14. Your Radiologist Explains Magnetic Resonance Angiography (MRA)

    Medline Plus

    Full Text Available ... Recently posted: Carotid Intima-Media Thickness Test Medical Imaging Costs Video: Abdominal Ultrasound Video: Pelvic Ultrasound Radiology and You Take our survey Sponsored by Image/Video Gallery Your Radiologist Explains Magnetic Resonance Angiography (MRA) Transcript Welcome to Radiology Info dot ...

  15. Modelling Strategies for Functional Magnetic Resonance Imaging

    DEFF Research Database (Denmark)

    Madsen, Kristoffer Hougaard

    2009-01-01

    This thesis collects research done on several models for the analysis of functional magnetic resonance neuroimaging (fMRI) data. Several extensions for unsupervised factor analysis type decompositions including explicit delay modelling as well as handling of spatial and temporal smoothness...

  16. Sensorineural hearing loss after magnetic resonance imaging

    DEFF Research Database (Denmark)

    Mollasadeghi, Abolfazl; Mehrparvar, Amir Houshang; Atighechi, Saeid

    2013-01-01

    Magnetic resonance imaging (MRI) devices produce noise, which may affect patient's or operators' hearing. Some cases of hearing impairment after MRI procedure have been reported with different patterns (temporary or permanent, unilateral or bilateral, with or without other symptoms like tinnitus...

  17. Functional Magnetic Resonance Imaging in Consumer Research

    DEFF Research Database (Denmark)

    Reimann, Martin; Schilke, Oliver; Weber, Bernd

    2011-01-01

    Although the field of psychology is undergoing an immense shift toward the use of functional magnetic resonance imaging (fMRI), the application of this methodology to consumer research is relatively new. To assist consumer researchers in understanding fMRI, this paper elaborates on the findings...

  18. Magnetic resonance imaging (MRI) in syringomyelia

    NARCIS (Netherlands)

    H.L.J. Tanghe (Hervé)

    1995-01-01

    textabstractBased on an own material of 19 patients with syringomyelia and on the related literature a survey is given on the diagnosis, differential diagnosis, postoperative evaluation and the dynamics of CSF and cyst fluids, using magnetic resonance imaging (MRI). The following conclusions can

  19. Evaluation of nuclear magnetic resonance spectroscopy variability

    Energy Technology Data Exchange (ETDEWEB)

    Barreto, Felipe Rodrigues; Salmon, Carlos Ernesto Garrido, E-mail: garrido@ffclrp.usp.br [Universidade de Sao Paulo (FFCLRP/USP), Ribeirao Preto, SP (Brazil). Fac. de Filisofia, Ciencias e Letras; Otaduy, Maria Concepcion Garcia [Universidade de Sao Paulo (FAMUS/USP), Sao Paulo, SP (Brazil). Fac. de Medicina. Departamento de Radiologia

    2014-11-01

    Introduction: the intrinsically high sensitivity of Magnetic Resonance Spectroscopy (MRS) causes considerable variability in metabolite quantification. In this study, we evaluated the variability of MRS in two research centers using the same model of magnetic resonance image scanner. Methods: two metabolic phantoms were created to simulate magnetic resonance spectra from in vivo hippocampus. The phantoms were filled with the same basic solution containing the following metabolites: N-acetyl-aspartate, creatine, choline, glutamate, glutamine and inositol. Spectra were acquired over 15 months on 26 acquisition dates, resulting in a total of 130 spectra per center. Results: the phantoms did not undergo any physical changes during the 15-month period. Temporal analysis from both centers showed mean metabolic variations of 3.7% in acquisitions on the same day and of 8.7% over the 15-month period. Conclusion: The low deviations demonstrated here, combined with the high specificity of Magnetic Resonance Spectroscopy, confirm that it is feasible to use this technique in multicenter studies in neuroscience research. (author)

  20. Measurement of myocardial perfusion using magnetic resonance

    DEFF Research Database (Denmark)

    Fritz-Hansen, T.; Jensen, L.T.; Larsson, H.B.

    2008-01-01

    Cardiac magnetic resonance imaging (MRI) has evolved rapidly. Recent developments have made non-invasive quantitative myocardial perfusion measurements possible. MRI is particularly attractive due to its high spatial resolution and because it does not involve ionising radiation. This paper reviews...

  1. Monitoring angiogenesis using magnetic resonance methods

    DEFF Research Database (Denmark)

    Peters, David Alberg

    2008-01-01

    and the involved signaling molecules. Subsequently, a short review of contrast agents and perfusion measurements is given. Finally, methods for monitoring angiogenesis using magnetic resonance imaging are reviewed. A method for monitoring early stages of angiogenesis as well as the effect of anti...

  2. Moving dislocations studied by nuclear magnetic resonance

    NARCIS (Netherlands)

    Hut, Gezinus

    1976-01-01

    In this thesis a new approach to the study of moving dislocations in crystalline solids during plastic deformation will be presented. Since the process of dislocation motion is made up of atomic movements nuclear magnetic resonance techniques should offer a possibility to determine the manner in

  3. Magnetic resonance imaging of breast prostheses

    African Journals Online (AJOL)

    G5

    ... these two signs,. 7. SA JOURNAL OF RADIOLOGY • October 2005. REVIEW ARTICLE. Magnetic resonance imaging of breast prostheses. P Corr. FFRad (D) SA. P Seolall. Nat Dip Rad (D). H Booth. Nat Dip Rad (D). Department of Radiology. Nelson Mandela School of Medicine and Inkosi Albert Luthuli Hospital. Durban ...

  4. Nuclear Magnetic Resonance Technology for Medical Studies.

    Science.gov (United States)

    Budinger, Thomas F.; Lauterbur, Paul C.

    1984-01-01

    Reports on the status of nuclear magnetic resonance (NMR) from theoretical and clinical perspectives, reviewing NMR theory and relaxation parameters relevant to NMR imaging. Also reviews literature related to modern imaging strategies, signal-to-noise ratio, contrast agents, in vivo spectroscopy, spectroscopic imaging, clinical applications, and…

  5. Magnetic Resonance Lithography with Nanometer Resolution

    Directory of Open Access Journals (Sweden)

    Fahad AlGhannam

    2016-04-01

    Full Text Available We propose an approach for super-resolution optical lithography which is based on the inverse of magnetic resonance imaging (MRI. The technique uses atomic coherence in an ensemble of spin systems whose final state population can be optically detected. In principle, our method is capable of producing arbitrary one and two dimensional high-resolution patterns with high contrast.

  6. Breast magnetic resonance imaging guided biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Yun, Bo La; Kim, Sun Mi; Jang, Mi Jung [Dept. of Radiology, Seoul National University Bundang Hospital, Seongnam (Korea, Republic of); Cho, Nariya; Moon, Woo Kyung [Dept. of Radiology, Seoul National University Hospital, Seoul (Korea, Republic of); Kim, Hak Hee [Dept. of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of)

    2016-06-15

    Despite the high sensitivity of breast magnetic resonance imaging (MRI), pathologic confirmation by biopsy is essential because of limited specificity. MRI-guided biopsy is required in patients with lesions only seen on MRI. We review preprocedural considerations and the technique of MRI-guided biopsy, challenging situations and trouble-shooting, and correlation of radiologic and pathologic findings.

  7. Your Radiologist Explains Magnetic Resonance Angiography (MRA)

    Medline Plus

    Full Text Available ... Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions ... Magnetic Resonance Angiography (MRA) Transcript Welcome to Radiology Info dot org Hello, I’m Dr. Elliot Fishman, ...

  8. Magnetic resonance imaging study of corpus callosum ...

    African Journals Online (AJOL)

    We recruited 58 chronically schizophrenic patients with different subtypes, and 31 age-and-gender matched healthy controls. The callosum was extracted from a midsagittal slice from T1 weighted magnetic resonance images, and areas of the total CC, its five subregions, CC length and total brain volume were compared ...

  9. Numerical methods in electron magnetic resonance

    Energy Technology Data Exchange (ETDEWEB)

    Soernes, A.R

    1998-07-01

    The focal point of the thesis is the development and use of numerical methods in the analysis, simulation and interpretation of Electron Magnetic Resonance experiments on free radicals in solids to uncover the structure, the dynamics and the environment of the system.

  10. Your Radiologist Explains Magnetic Resonance Angiography (MRA)

    Medline Plus

    Full Text Available ... Radiology (IDoR) Radiology and You Sponsored by Image/Video Gallery Your Radiologist Explains Magnetic Resonance Angiography (MRA) ... Carotid Intima-Media Thickness Test Medical Imaging Costs Video: Abdominal Ultrasound Video: Pelvic Ultrasound November 8 is ...

  11. Magnetic Resonance, Functional (fMRI) -- Brain

    Science.gov (United States)

    ... parts of the body and determine the presence of certain diseases. The images can then be examined on a computer monitor, transmitted electronically, printed or copied to a CD or uploaded to a digital cloud server. Functional magnetic resonance imaging (fMRI) is ...

  12. Magnetic resonance imaging of infectious myositis

    Energy Technology Data Exchange (ETDEWEB)

    Yun, Ji Young; Kim, Jee Young; Kim, Sang Heum; Jung, Youn Ju; Cha, Eun Suk; Park, Joung Mi; Park, Young Ha [The Catholic Univ., College of Medicine, Suwon (Korea, Republic of)

    1998-09-01

    To describe the findings of magnetic resonance imaging in infectious myositis and to determine their value for differentiation between ruberculous and bacterial myositis. Magnetic resonance images of ten proven cases of infectious myositis (five tuberculous and five bacterial) were retrospectively reviewed in the light of clinical and laboratory findings. On the basis of magnetic resonance images, signal intensity of the mass, the presence or absence of an abscess, signal intensity of the peripheral wall, patterns of contrast enhancement, and associated findings were evaluated. Compared with those of bacterial myositis, the symptoms of tuberculous myositis lasted longer but there were no difinite local inflammatory signs. In three of five cases of bacterial myositis there were specific medical records;trauma in two cases and systemic lupus erythematosus in one. All tuberculous myositis cases involved a single muscle, but bacterial myositis affected multipe muscles in three cases(60%). All but one case showed a mass in the involved muscles. In one bacterial case, there was diffuse swelling in the involved muscle. On T1-weighted images, eight infectious cases showed low signal intensity;two, of the bactrerial type, showed subtle increased signal intensity. all cases demonstrated high signal intensity on t2-weighted images. The signal intensity of peripheral wall was slightly increased on T1-weighted images, but low on T2-weighted. In four cases there was associated cellulitis, and in one case each, adjacent joint effusion and deep vein thrombosis were seen. After gadolinium infusion, peripheral rim enhancement was noted in nine cases and heterogeneous enhancement in one. After magnetic resonance imaging of infectious myositis, the characteristic finding was an abscessed lesion, with the peripheral wall showing high signal intensity on T1-weighted images and low signal intensity on T2 weighted. Although we found it difficult to differentiate bacterial from tuberculous

  13. The working principle of magnetic resonance therapy

    CERN Document Server

    Brizhik, Larissa; Fermi, Enrico

    2015-01-01

    In this paper we describe briefly the basic aspects of magnetic resonance therapy, registered as TMR therapy. Clinical studies have shown that application of this therapy significantly accelerates wound healing and, in particular, healing of the diabetic foot disease. To understand the working principle of this therapy, we analyze relevant to it biological effects produced by magnetic fields. Based on these data, we show that there is a hierarchy of the possible physical mechanisms, which can produce such effects. The mutual interplay between the mechanisms can lead to a synergetic outcome delayed in time, which can affect the physiological state of the organism. In particular, we show that soliton mediated charge transport during the redox processes in living organisms is sensitive to magnetic fields, so that such fields can facilitate redox processes in particular, and can stimulate the healing effect of the organism in general. This and other non-thermal resonant mechanisms of the biological effects of mag...

  14. Magnetic resonance imaging in inflammatory rheumatoid diseases.

    Science.gov (United States)

    Sudoł-Szopińska, Iwona; Mróz, Joanna; Ostrowska, Monika; Kwiatkowska, Brygida

    2016-01-01

    Magnetic resonance (MR) is used more and more frequently to diagnose changes in the musculoskeletal system in the course of rheumatic diseases, at their initial assessment, for treatment monitoring and for identification of complications. The article presents the history of magnetic resonance imaging, the basic principles underlying its operation as well as types of magnets, coils and MRI protocols used in the diagnostic process of rheumatic diseases. It enumerates advantages and disadvantages of individual MRI scanners. The principles of MRI coil operation are explained, and the sequences used for MR image analysis are described, particularly in terms of their application in rheumatology, including T1-, T2-, PD-weighted, STIR/TIRM and contrast-enhanced T1-weighted images. Furthermore, views on the need to use contrast agents to optimise diagnosis, particularly in synovitis-like changes, are presented. Finally, methods for the assessment of MR images are listed, including the semi-quantitative method by RAMRIS and quantitative dynamic examination.

  15. Magnetic resonance imaging of aneurysmal subarachnoid hemorrhage

    Energy Technology Data Exchange (ETDEWEB)

    Ogawa, Toshihide; Shimosegawa, Eku; Inugami, Atsushi; Shishido, Fumio; Fujita, Hideaki; Ito, Hiroshi; Uemura, Kazuo; Yasui, Nobuyuki (Research Inst. of Brain and Blood Vessels, Akita (Japan))

    1991-11-01

    Magnetic resonance imaging of subarachnoid hemorrhage (SAH) due to aneurysm rupture was evaluated in relation to CT findings in nine patients. Six patients were studied within 3 days and the other three patients were studied 4 to 6 days from the ictus of SAH using a 0.5 Tesla superconducting unit. In all of the patients, hematoma in the subarachnoid space and ventricles was demonstrated by the proton density-weighted spin echo sequence, which showed that bloody cerebrospinal fluid (CSF) had a higher signal intensity than brain tissue or normal CSF. Magnetic resonance imaging was more sensitive in detecting SAH and more informative as to the site of the ruptured aneurysm than CT. Despite some limitations in applying it to patients with acute SAH, magnetic resonace imaging has clear advantages in the diagnosis of SAH. (author).

  16. Magnetic Resonance Imaging (MRI): Lumbar Spine (For Parents)

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español Magnetic Resonance Imaging (MRI): Lumbar Spine KidsHealth / For Parents / Magnetic Resonance Imaging (MRI): Lumbar Spine What's in this article? What ...

  17. Role of magnetic resonance venography in evaluation of cerebral ...

    African Journals Online (AJOL)

    Eman Abd-El Latif Abd-Elaziz El Damarawy

    2011-12-14

    Dec 14, 2011 ... Abbreviations: MRI, magnetic resonance imaging; MRV, magnetic resonance venography; SSS, superior sagittal sinus; CVO, cerebral venous occlusion; CVT, cerebral venous thrombosis; DSA, digital subtraction angiography; CT, computed tomography; CTV, computed tomography venography; CVST ...

  18. Brain magnetic resonance imaging examination in a patient with non-magnetic resonance conditional pacemaker

    Directory of Open Access Journals (Sweden)

    Toshiko Nakai, MD

    2017-10-01

    Full Text Available Clinical dilemmas arise when patients with a non-magnetic resonance (MR conditional pacemaker are required to undergo magnetic resonance imaging (MRI. We encountered a pacemaker patient with debilitating non-motor symptoms of Parkinson׳s disease, who required an MRI prior to deep brain stimulation (DBS surgery. MRI was performed safely without adverse events despite the presence of a conventional pacemaker.

  19. Brain magnetic resonance imaging and magnetic resonance spectroscopy findings of children with kernicterus

    OpenAIRE

    Sarı, Sahabettin; Yavuz, Alpaslan; Batur, Aabdussamet; Bora, Aydın; Caksen, Huseyin

    2015-01-01

    Summary Background The term kernicterus, or bilirubin encephalopathy, is used to describe pathological bilirubin staining of the basal ganglia, brain stem, and cerebellum, and is associated with hyperbilirubinemia. Kernicterus generally occurs in untreated hyperbilirubinemia or cases where treatment is delayed. Magnetic resonance imaging (MRI)-based studies have shown characteristic findings in kernicterus. The objective of our study was to describe the role of 1H magnetic resonance spectrosc...

  20. Magnetic resonance techniques for investigation of multiple sclerosis

    Science.gov (United States)

    MacKay, Alex; Laule, Cornelia; Li, David K. B.; Meyers, Sandra M.; Russell-Schulz, Bretta; Vavasour, Irene M.

    2014-11-01

    Multiple sclerosis (MS) is a common neurological disease which can cause loss of vision and balance, muscle weakness, impaired speech, fatigue, cognitive dysfunction and even paralysis. The key pathological processes in MS are inflammation, edema, myelin loss, axonal loss and gliosis. Unfortunately, the cause of MS is still not understood and there is currently no cure. Magnetic resonance imaging (MRI) is an important clinical and research tool for MS. 'Conventional' MRI images of MS brain reveal bright lesions, or plaques, which demark regions of severe tissue damage. Conventional MRI has been extremely valuable for the diagnosis and management of people who have MS and also for the assessment of therapies designed to reduce inflammation and promote repair. While conventional MRI is clearly valuable, it lack pathological specificity and, in some cases, sensitivity to non-lesional pathology. Advanced MR techniques have been developed to provide information that is more sensitive and specific than what is available with clinical scanning. Diffusion tensor imaging and magnetization transfer provide a general but non-specific measure of the pathological state of brain tissue. MR spectroscopy provides concentrations of brain metabolites which can be related to specific pathologies. Myelin water imaging was designed to assess brain myelination and has proved useful for measuring myelin loss in MS. To combat MS, it is crucial that the pharmaceutical industry finds therapies which can reverse the neurodegenerative processes which occur in the disease. The challenge for magnetic resonance researchers is to design imaging techniques which can provide detailed pathological information relating to the mechanisms of MS therapies. This paper briefly describes the pathologies of MS and demonstrates how MS-associated pathologies can be followed using both conventional and advanced MR imaging protocols.

  1. Spin echo magnetic resonance imaging.

    Science.gov (United States)

    Jung, Bernd André; Weigel, Matthias

    2013-04-01

    The spin echo sequence is a fundamental pulse sequence in MRI. Many of today's applications in routine clinical use are based on this elementary sequence. In this review article, the principles of the spin echo formation are demonstrated on which the generation of the fundamental image contrasts T1, T2, and proton density is based. The basic imaging parameters repetition time (TR) and echo time (TE) and their influence on the image contrast are explained. Important properties such as the behavior in multi-slice imaging or in the presence of flow are depicted and the basic differences with gradient echo imaging are illustrated. The characteristics of the spin echo sequence for different magnetic field strengths with respect to clinical applications are discussed. Copyright © 2013 Wiley Periodicals, Inc.

  2. 76 FR 58281 - Magnetic Resonance Imaging Safety; Public Workshop

    Science.gov (United States)

    2011-09-20

    ... HUMAN SERVICES Food and Drug Administration Magnetic Resonance Imaging Safety; Public Workshop AGENCY... the safe use of magnetic resonance imaging (MRI) and approaches to mitigate risks. The overall goal is...: The Food and Drug Administration (FDA) is announcing a public workshop entitled: ``Magnetic Resonance...

  3. Role of proton magnetic resonance spectroscopy in diagnosis of ...

    African Journals Online (AJOL)

    Magnetic resonance (MR) imaging was performed at 1.5 Tesla MR system using a standard head coil. Imaging included conventional MRI and proton magnetic resonance spectroscopy. Proton magnetic resonance spectroscopy was done using either single or multi-voxel technique. Surgical biopsy was then performed to ...

  4. TensorLy: Tensor Learning in Python

    NARCIS (Netherlands)

    Kossaifi, Jean; Panagakis, Yannis; Pantic, Maja

    2016-01-01

    Tensor methods are gaining increasing traction in machine learning. However, there are scant to no resources available to perform tensor learning and decomposition in Python. To answer this need we developed TensorLy. TensorLy is a state of the art general purpose library for tensor learning.

  5. Renal ablation using magnetic resonance-guided high intensity focused ultrasound: Magnetic resonance imaging and histopathology assessment

    OpenAIRE

    Saeed, Maythem; Krug, Roland; Do, Loi; Steven W. Hetts; Wilson, Mark W.

    2016-01-01

    AIM: To use magnetic resonance-guided high intensity focused ultrasound (MRg-HIFU), magnetic resonance imaging (MRI) and histopathology for noninvasively ablating, quantifying and characterizing ablated renal tissue.

  6. The proton pressure tensor as a new proxy of the proton decoupling region in collisionless magnetic reconnection

    Directory of Open Access Journals (Sweden)

    N. Aunai

    2011-09-01

    Full Text Available Cluster data is analyzed to test the proton pressure tensor variations as a proxy of the proton decoupling region in collisionless magnetic reconnection. The Hall electric potential well created in the proton decoupling region results in bounce trajectories of the protons which appears as a characteristic variation of one of the in-plane off-diagonal components of the proton pressure tensor in this region. The event studied in this paper is found to be consistent with classical Hall field signatures with a possible 20% guide field. Moreover, correlations between this pressure tensor component, magnetic field and bulk flow are proposed and validated, together with the expected counterstreaming proton distribution functions.

  7. Magnetic Resonance Imaging Methods in Soil Science

    Science.gov (United States)

    Pohlmeier, A.; van Dusschoten, D.; Blümler, P.

    2009-04-01

    Magnetic Resonance Imaging (MRI) is a powerful technique to study water content, dynamics and transport in natural porous media. However, MRI systems and protocols have been developed mainly for medical purposes, i.e. for media with comparably high water contents and long relaxation times. In contrast, natural porous media like soils and rocks are characterized by much lower water contents, typically 0 Raich H, and Blümler P, Concepts in Magn. Reson. B 23B, 16-25 (2004) 4) Pohlmeier et al. Magn. Res. Imag. doi:10.1016/j.mri.2008.06.007 (2008)

  8. Advances in magnetic and optical resonance

    CERN Document Server

    Warren, Warren S

    2013-01-01

    Advances in Magnetic and Optical Resonance contains three articles which review quite fundamentally different aspects of coherent spectroscopy. An enormous variety of effects can be observed when optical and spin resonances are coupled, usually by a combination of radio frequency and laser irradiation. The first article reviews these effects and pays particular attention to developing a theoretical framework which is as similar as possible for the optical and spin cases. Subsequent articles examine deuterium relaxation in molecular solids, and the spatiotemporal growth of multiple spin coheren

  9. A hyperpolarized equilibrium for magnetic resonance

    Science.gov (United States)

    Hövener, Jan-Bernd; Schwaderlapp, Niels; Lickert, Thomas; Duckett, Simon B.; Mewis, Ryan E.; Highton, Louise A. R.; Kenny, Stephen M.; Green, Gary G. R.; Leibfritz, Dieter; Korvink, Jan G.; Hennig, Jürgen; von Elverfeldt, Dominik

    2013-12-01

    Nuclear magnetic resonance spectroscopy and imaging (MRI) play an indispensable role in science and healthcare but use only a tiny fraction of their potential. No more than ≈10 p.p.m. of all 1H nuclei are effectively detected in a 3-Tesla clinical MRI system. Thus, a vast array of new applications lays dormant, awaiting improved sensitivity. Here we demonstrate the continuous polarization of small molecules in solution to a level that cannot be achieved in a viable magnet. The magnetization does not decay and is effectively reinitialized within seconds after being measured. This effect depends on the long-lived, entangled spin-order of parahydrogen and an exchange reaction in a low magnetic field of 10-3 Tesla. We demonstrate the potential of this method by fast MRI and envision the catalysis of new applications such as cancer screening or indeed low-field MRI for routine use and remote application.

  10. A Portable Nuclear Magnetic Resonance Sensor System

    Directory of Open Access Journals (Sweden)

    R. Dykstra

    2008-04-01

    Full Text Available Nuclear Magnetic Resonance (NMR is a relatively complex technique and normally requires expensive equipment, however with advances in computing, electronics and permanent magnet technologies, NMR is becoming more feasible as a non-invasive tool for industry. The strength of NMR is its ability to probe at the molecular level and hence gain information about molecular structure, organization, abundance and orientation. This paper presents some of the work being undertaken in developing portable NMR systems for the non-destructive testing of materials such as polymer composites, rubber, timber and concrete.

  11. Magnetic resonance imaging findings in tuberculous meningoencephalitis

    Energy Technology Data Exchange (ETDEWEB)

    Pui, M.H.; Memon, W.A. [Aga Khan Univ. Hospital, Dept. of Radiology, Karachi (Pakistan)

    2001-02-01

    To evaluate the efficacy of magnetic resonance imaging (MRI) for distinguishing tuberculosis from other types of meningoencephalitis. MRIs of 100 patients with tuberculous (50), pyogenic (33), viral (14), or fungal (3) meningoencephalitis were analyzed independently by 2 radiologists. Number, size, location, signal characteristics, surrounding edema, and contrast enhancement pattern of nodular lesions; location and pattern of meningeal enhancement; extent of infarct or encephalitis and hydrocephalus were evaluated. Contrast-enhancing nodular lesions were detected in patients with tuberculous (43 of 50 patients), pyogenic (9 of 33), and fungal (3 of 3) infections. No nodules were detected in patients with viral meningoencephalitis. Using the criteria of 1 or more solid rim or homogeneously enhancing nodules smaller than 2 cm, the sensitivity, specificity and accuracy for diagnosing tuberculous meningitis were 86.0%, 90.0% and 88.0%, respectively. Magnetic resonance imaging is useful in distinguishing tuberculous from pyogenic, viral and fungal meningoencephalitis. (author)

  12. Contribution of magnetic resonance imaging in rheumatology

    Energy Technology Data Exchange (ETDEWEB)

    Lavieille, J.; Amalric, R.; Stanoyevitch, J.F.; Hopf, M.A.; Antipoff, G.M.; Roux, H.

    1986-11-01

    The authors report their experience with magnetic resonance imaging in rheumatology, established on more than 250 examinations. The method seems interesting for the study of discal and somatic spine diseases, and especially for the evaluation of tumor extension, the diagnosis of herniated disc, the diagnosis of spondylodiscitis, the exploration of the cervico-occipital joint. As compared to tomodensitometry, this method presents at the same time advantages and drawbacks. Peripherally, magnetic resonance imaging is useful for the exploration of bony tumors and evaluation of their extension. It gives excellent images of the knees and the hips where it seems to improve the results of tomodensitometry and bony scintigraphy in the diagnosis of osteonecrosis. It is likely that advances will broaden the scope of the indications and capabilities of this method.

  13. Magnetic resonance semiotics of breast fibroadenomas

    Directory of Open Access Journals (Sweden)

    S. V. Serebryakova

    2010-01-01

    Full Text Available Various benign breast abnormalities are diagnosed in 60% of women in Russia today. This is associated with failure of preoperative recognition of the histological class of an identified nodular mass – its detection is an indication for surgical treatment. By using 67 histologically verified breast fibroadenomas (FA as an example, the authors describe their magnetic resonance semiotics and present the differential diagnostic criteria used during dynamic contrast-enhanced magnetic resonance mammography. FAs are characterized by well-defined uniform outlines, homogeneous internal structure, centrifugal and homogeneous accumulation of contrast media through- out the study, without deforming the breast vasculature around. One of the criteria that permit differential diagnosis of FA with malignan- cies is their estimated vascularization.

  14. Magnetic resonance tomography of the penis

    Energy Technology Data Exchange (ETDEWEB)

    Vogel, H.; Taieb, A.; Vadrot, D.

    1986-03-01

    The magnetic resonance tomogram visualises the corpus spongiosum, the corpora cavernosa, the fascia penis profunda, the septum and the dorsal vein of the penis. These structures can be separated from the skin and from the glans penis. Changes of shape are still the essential criteria of assessment. At present it does not seem possible to be able to differentiate between diseased and healthy area if the connective tissue structures of the penis (e.g. in induratio penis plastica) do not show any change of shape. Compared with other imaging methods, imaging on different levels offers advantages, and so does the simultaneous imaging of the structures of the penis, of its environment and of the adjacent organs. We can assume that the magnetic resonance tomogram will supply essential additional information for clinical diagnosis and practice in conditions like induratio penis plastica, intersexuality, tumours of the prostate gland, and in postoperative follow-up, for example after surgery for priapism.

  15. Caroli's disease: magnetic resonance imaging features.

    Science.gov (United States)

    Guy, France; Cognet, François; Dranssart, Marie; Cercueil, Jean-Pierre; Conciatori, Laurent; Krausé, Denis

    2002-11-01

    Our objective was to describe the main aspects of MR imaging in Caroli's disease. Magnetic resonance cholangiography with a dynamic contrast-enhanced study was performed in nine patients with Caroli's disease. Bile duct abnormalities, lithiasis, dot signs, hepatic enhancement, renal abnormalities, and evidence of portal hypertension were evaluated. Three MR imaging patterns of Caroli's disease were found. In all but two patients, MR imaging findings were sufficient to confirm the diagnosis. Moreover, MR imaging provided information about the severity, location, and extent of liver involvement. This information was useful in planning the best therapeutic strategy. Magnetic resonance cholangiography with a dynamic contrast-enhanced study is a good screening tool for Caroli's disease. Direct cholangiography should be reserved for confirming doubtful cases.

  16. [Nuclear magnetic resonance tomography in gynecologic tumors].

    Science.gov (United States)

    Pfändner, K; Hötzinger, H; Atzinger, A; Ries, G

    1983-09-01

    The article discusses initial experiences of NMR examinations of carcinoma of the uterus and cervix uteri (resistive magnet, NMR prototype of Siemens). All examined carcinomas show prolonged relaxation times. Variation of measurement parameters results in good optical presentation of carcinoma tissue in the resonance scans. The results are compared with those of CT-scans and in one case with the site of the operation.

  17. NON-CONTRAST MAGNETIC RESONANCE UROGRAPHY

    OpenAIRE

    Arpita C; Nava Kishore K; Ananda Reddy C; Dushyanth M

    2016-01-01

    BACKGROUND AND PURPOSE Magnetic Resonance (MR) urography with its optimal contrast resolution and lack of ionizing radiation provides a comprehensive examination of the entire urinary tract noninvasively. MR urography is clinically useful in the evaluation of suspected urinary tract obstruction, haematuria, congenital anomalies, and surgically altered anatomy. It is particularly useful in cases of where there is contraindication of ionizing radiation and in paediatric and pregn...

  18. Nuclear magnetic resonance in Kondo lattice systems

    Science.gov (United States)

    Curro, Nicholas J.

    2016-06-01

    Nuclear magnetic resonance has emerged as a vital tool to explore the fundamental physics of Kondo lattice systems. Because nuclear spins experience two different hyperfine couplings to the itinerant conduction electrons and to the local f moments, the Knight shift can probe multiple types of spin correlations that are not accessible via other techniques. The Knight shift provides direct information about the onset of heavy electron coherence and the emergence of the heavy electron fluid.

  19. Breast Tissue Metabolism by Magnetic Resonance Spectroscopy.

    Science.gov (United States)

    Jagannathan, Naranamangalam R; Sharma, Uma

    2017-06-07

    Metabolic alterations are known to occur with oncogenesis and tumor progression. During malignant transformation, the metabolism of cells and tissues is altered. Cancer metabolism can be studied using advanced technologies that detect both metabolites and metabolic activities. Identification, characterization, and quantification of metabolites (metabolomics) are important for metabolic analysis and are usually done by nuclear magnetic resonance (NMR) or by mass spectrometry. In contrast to the magnetic resonance imaging that is used to monitor the tumor morphology during progression of the disease and during therapy, in vivo NMR spectroscopy is used to study and monitor tumor metabolism of cells/tissues by detection of various biochemicals or metabolites involved in various metabolic pathways. Several in vivo, in vitro and ex vivo NMR studies using ¹H and 31P magnetic resonance spectroscopy (MRS) nuclei have documented increased levels of total choline containing compounds, phosphomonoesters and phosphodiesters in human breast cancer tissues, which is indicative of altered choline and phospholipid metabolism. These levels get reversed with successful treatment. Another method that increases the sensitivity of substrate detection by using nuclear spin hyperpolarization of 13C-lableled substrates by dynamic nuclear polarization has revived a great interest in the study of cancer metabolism. This review discusses breast tissue metabolism studied by various NMR/MRS methods.

  20. Breast Tissue Metabolism by Magnetic Resonance Spectroscopy

    Directory of Open Access Journals (Sweden)

    Naranamangalam R. Jagannathan

    2017-06-01

    Full Text Available Metabolic alterations are known to occur with oncogenesis and tumor progression. During malignant transformation, the metabolism of cells and tissues is altered. Cancer metabolism can be studied using advanced technologies that detect both metabolites and metabolic activities. Identification, characterization, and quantification of metabolites (metabolomics are important for metabolic analysis and are usually done by nuclear magnetic resonance (NMR or by mass spectrometry. In contrast to the magnetic resonance imaging that is used to monitor the tumor morphology during progression of the disease and during therapy, in vivo NMR spectroscopy is used to study and monitor tumor metabolism of cells/tissues by detection of various biochemicals or metabolites involved in various metabolic pathways. Several in vivo, in vitro and ex vivo NMR studies using 1H and 31P magnetic resonance spectroscopy (MRS nuclei have documented increased levels of total choline containing compounds, phosphomonoesters and phosphodiesters in human breast cancer tissues, which is indicative of altered choline and phospholipid metabolism. These levels get reversed with successful treatment. Another method that increases the sensitivity of substrate detection by using nuclear spin hyperpolarization of 13C-lableled substrates by dynamic nuclear polarization has revived a great interest in the study of cancer metabolism. This review discusses breast tissue metabolism studied by various NMR/MRS methods.

  1. Breast Tissue Metabolism by Magnetic Resonance Spectroscopy

    Science.gov (United States)

    Jagannathan, Naranamangalam R.; Sharma, Uma

    2017-01-01

    Metabolic alterations are known to occur with oncogenesis and tumor progression. During malignant transformation, the metabolism of cells and tissues is altered. Cancer metabolism can be studied using advanced technologies that detect both metabolites and metabolic activities. Identification, characterization, and quantification of metabolites (metabolomics) are important for metabolic analysis and are usually done by nuclear magnetic resonance (NMR) or by mass spectrometry. In contrast to the magnetic resonance imaging that is used to monitor the tumor morphology during progression of the disease and during therapy, in vivo NMR spectroscopy is used to study and monitor tumor metabolism of cells/tissues by detection of various biochemicals or metabolites involved in various metabolic pathways. Several in vivo, in vitro and ex vivo NMR studies using 1H and 31P magnetic resonance spectroscopy (MRS) nuclei have documented increased levels of total choline containing compounds, phosphomonoesters and phosphodiesters in human breast cancer tissues, which is indicative of altered choline and phospholipid metabolism. These levels get reversed with successful treatment. Another method that increases the sensitivity of substrate detection by using nuclear spin hyperpolarization of 13C-lableled substrates by dynamic nuclear polarization has revived a great interest in the study of cancer metabolism. This review discusses breast tissue metabolism studied by various NMR/MRS methods. PMID:28590405

  2. Electromagnetic momentum and the energy–momentum tensor in a linear medium with magnetic and dielectric properties

    Energy Technology Data Exchange (ETDEWEB)

    Crenshaw, Michael E., E-mail: michael.e.crenshaw4.civ@mail.mil [US Army Aviation and Missile Research, Development, and Engineering Center, Redstone Arsenal, Alabama 35898 (United States)

    2014-04-15

    In a continuum setting, the energy–momentum tensor embodies the relations between conservation of energy, conservation of linear momentum, and conservation of angular momentum. The well-defined total energy and the well-defined total momentum in a thermodynamically closed system with complete equations of motion are used to construct the total energy–momentum tensor for a stationary simple linear material with both magnetic and dielectric properties illuminated by a quasimonochromatic pulse of light through a gradient-index antireflection coating. The perplexing issues surrounding the Abraham and Minkowski momentums are bypassed by working entirely with conservation principles, the total energy, and the total momentum. We derive electromagnetic continuity equations and equations of motion for the macroscopic fields based on the material four-divergence of the traceless, symmetric total energy–momentum tensor. We identify contradictions between the macroscopic Maxwell equations and the continuum form of the conservation principles. We resolve the contradictions, which are the actual fundamental issues underlying the Abraham–Minkowski controversy, by constructing a unified version of continuum electrodynamics that is based on establishing consistency between the three-dimensional Maxwell equations for macroscopic fields, the electromagnetic continuity equations, the four-divergence of the total energy–momentum tensor, and a four-dimensional tensor formulation of electrodynamics for macroscopic fields in a simple linear medium.

  3. Portal biliopathy, magnetic resonance imaging and magnetic resonance cholangiopancreatography findings: a case series.

    Science.gov (United States)

    Baskan, Ozdil; Erol, Cengiz; Sahingoz, Yusuf

    2016-02-01

    Portal biliopathy (PB) is a rare disorder, characterized by biliary ductal and gallbladder wall abnormalities seen in patients with portal hypertension. It most commonly occurs due to idiopathic extrahepatic portal vein obstruction (EHPVO). The abnormalities consist mainly of bile duct compression, stenoses, fibrotic strictures and dilation of both extrahepatic and intrahepatic bile ducts, as well as gallbladder varices. PB may mimic cholangiocarcinoma, sclerosing cholangitis, or choledocholithiasis. Misdiagnosis can be avoided using appropriate imaging modalities to prevent complications. We present the magnetic resonance imaging (MRI) and magnetic resonance cholangiography (MRCP) features of three patients with PB. © The Author(s) 2014. Published by Oxford University Press and the Digestive Science Publishing Co. Limited.

  4. Accuracy of magnetic resonance based susceptibility measurements

    Science.gov (United States)

    Erdevig, Hannah E.; Russek, Stephen E.; Carnicka, Slavka; Stupic, Karl F.; Keenan, Kathryn E.

    2017-05-01

    Magnetic Resonance Imaging (MRI) is increasingly used to map the magnetic susceptibility of tissue to identify cerebral microbleeds associated with traumatic brain injury and pathological iron deposits associated with neurodegenerative diseases such as Parkinson's and Alzheimer's disease. Accurate measurements of susceptibility are important for determining oxygen and iron content in blood vessels and brain tissue for use in noninvasive clinical diagnosis and treatment assessments. Induced magnetic fields with amplitude on the order of 100 nT, can be detected using MRI phase images. The induced field distributions can then be inverted to obtain quantitative susceptibility maps. The focus of this research was to determine the accuracy of MRI-based susceptibility measurements using simple phantom geometries and to compare the susceptibility measurements with magnetometry measurements where SI-traceable standards are available. The susceptibilities of paramagnetic salt solutions in cylindrical containers were measured as a function of orientation relative to the static MRI field. The observed induced fields as a function of orientation of the cylinder were in good agreement with simple models. The MRI susceptibility measurements were compared with SQUID magnetometry using NIST-traceable standards. MRI can accurately measure relative magnetic susceptibilities while SQUID magnetometry measures absolute magnetic susceptibility. Given the accuracy of moment measurements of tissue mimicking samples, and the need to look at small differences in tissue properties, the use of existing NIST standard reference materials to calibrate MRI reference structures is problematic and better reference materials are required.

  5. Gadolinium-Enhanced Magnetic Resonance Angiography for Pulmonary Embolism

    Science.gov (United States)

    Stein, Paul D.; Chenevert, Thomas L.; Fowler, Sarah E.; Goodman, Lawrence R.; Gottschalk, Alexander; Hales, Charles A.; Hull, Russell D.; Jablonski, Kathleen A.; Leeper, Kenneth V.; Naidich, David P.; Sak, Daniel J.; Sostman, H. Dirk; Tapson, Victor F.; Weg, John G.; Woodard, Pamela K.

    2011-01-01

    Background The accuracy of gadolinium-enhanced magnetic resonance pulmonary angiography and magnetic resonance venography for diagnosing pulmonary embolism has not been determined conclusively. Objective To investigate performance characteristics of magnetic resonance angiography, with or without magnetic resonance venography, for diagnosing pulmonary embolism. Design Prospective, multicenter study from 10 April 2006 to 30 September 2008. (ClinicalTrials.gov registration number: NCT00241826) Setting 7 hospitals and their emergency services. Patients 371 adults with diagnosed or excluded pulmonary embolism. Measurements Sensitivity, specificity, and likelihood ratios were measured by comparing independently read magnetic resonance imaging with the reference standard for diagnosing pulmonary embolism. Reference standard diagnosis or exclusion was made by using various tests, including computed tomographic angiography and venography, ventilation–perfusion lung scan, venous ultra-sonography, D-dimer assay, and clinical assessment. Results Magnetic resonance angiography, averaged across centers, was technically inadequate in 25% of patients (92 of 371). The proportion of technically inadequate images ranged from 11% to 52% at various centers. Including patients with technically inadequate images, magnetic resonance angiography identified 57% (59 of 104) with pulmonary embolism. Technically adequate magnetic resonance angiography had a sensitivity of 78% and a specificity of 99%. Technically adequate magnetic resonance angiography and venography had a sensitivity of 92% and a specificity of 96%, but 52% of patients (194 of 370) had technically inadequate results. Limitation A high proportion of patients with suspected embolism was not eligible or declined to participate. Conclusion Magnetic resonance pulmonary angiography should be considered only at centers that routinely perform it well and only for patients for whom standard tests are contraindicated. Magnetic

  6. Magnetic resonance spectroscopy of the human brain

    Science.gov (United States)

    Strózik-Kotlorz, D.

    2014-01-01

    I give a brief description of the magnetic resonance spectroscopy (MRS) in the human brain examinations. MRS allows a noninvasive chemical analysis of the brain using a standard high field MR system. Nowadays, the dominant form of MR brain spectroscopy is proton spectroscopy. Two main techniques of MRS, which utilize the chemical shift of metabolites in the external magnetic field, are SVS (single voxel) and CSI (single slice). The major peaks in the spectrum of a normal brain include NAA, Cr, Cho and m-Ins, which are neuronal, energetic, membrane turnover and glial markers, respectively. In disease, two pathological metabolites can be found in the brain spectra: Lac, which is end product of anaerobic glycolysis and Lip, which is a marker of membrane breakdown, occurring in necrosis. The common way to analyze clinical spectra is to determine metabolite ratios, e.g. NAA/Cr, Cho/Cr, Cho/NAA. This analysis permits a safe and noninvasive examination of the brain tissue as each disease state has its own characteristic spectroscopic image. MRS is a valuable diagnostic tool in such clinical applications as detecting brain tumors and differentiating tumors from inflammatory and infectious processes. Proton MRS is also very helpful in diagnostic of ischemic lesions, Alzheimer's disease and hepatic encephalopathy. The MRS brain spectra should always be correlated with the Magnetic Resonance Imaging (MRI) results and alone cannot make neurological diagnosis.

  7. Magnetic resonance imaging: current and emerging applications in the study of the central nervous system.

    Science.gov (United States)

    Sanghvi, D A; Patel, Z; Patankar, T

    2010-01-01

    Neuroimaging is presently utilised in clinical practice for initial diagnosis and mapping of disease extent and distribution, noninvasive, preoperative grading of tumours, biopsy planning, surgery and radiation portal planning for tumors, judging response to therapy and finally, prognostication. Newer advances include magnetic resonance (MR) diffusion and diffusion tensor imaging with tractography, perfusion imaging, MR spectroscopy and functional imaging using the blood oxygen level-dependent contrast technique. Neuroimaging plays a pivotal role in various degenerative and neoplastic diseases, improving diagnostic accuracy, affecting patient care, monitoring dynamic changes within the brain during therapy, and establishing them as the arbiter of novel therapy that may one day prove cure of various brain diseases a reality.

  8. Structural and Functional Magnetic Resonance Imaging: Mild Cognitive Impairment and Alzheimer Disease.

    Science.gov (United States)

    Lockau, Hannah; Jessen, Frank; Fellgiebel, Andreas; Drzezga, Alexander

    2013-10-01

    Magnetic resonance (MR) imaging is playing an increasingly pivotal role in the clinical management of dementia, including Alzheimer disease (AD). In addition to established MR imaging procedures, the introduction of advanced instrumentation such as 7-T MR imaging, as well as novel MR imaging sequences such as arterial spin labeling, MR spectroscopy, diffusion tensor imaging, and resting-state functional MR imaging, may open new pathways toward improved diagnosis of AD even in early stages of disease such as mild cognitive impairment (MCI). This article describes the typical findings of established and new MR imaging procedures in healthy aging, MCI, and AD. Copyright © 2013 Elsevier Inc. All rights reserved.

  9. Magnetic resonance imaging of valvular heart disease

    DEFF Research Database (Denmark)

    Søndergaard, Lise; Ståhlberg, F; Thomsen, C

    1999-01-01

    The optimum management of patients with valvular heart diseases requires accurate and reproducible assessment of the valvular lesion and its hemodynamic consequences. Magnetic resonance imaging (MRI) techniques, such as volume measurements, signal-void phenomena, and velocity mapping, can be used...... in an integrated approach to gain qualitative and quantitative information on valvular heart disease as well as ventricular dimensions and functions. Thus, MRI may be advantageous to the established diagnostic tools in assessing the severity of valvular heart disease as well as monitoring the lesion and predicting...... the optimal timing for valvular surgery. This paper reviews the validation of these MRI techniques in assessing valvular heart disease and discusses some typical pitfalls of the techniques, including suggestions for solutions.J. Magn. Reson. Imaging 1999;10:627-638....

  10. Role of magnetic resonance venography in evaluation of cerebral ...

    African Journals Online (AJOL)

    Eman Abd-El Latif Abd-Elaziz El Damarawy

    2011-12-14

    Dec 14, 2011 ... Objective: To assess the role of magnetic resonance venography in the evaluation of cerebral veins and sinuses occlusion. Methods: The study was conducted on 15 patients with cerebral venous occlusion and subjected to. MRI and MRV. Abbreviations: MRI, magnetic resonance imaging; MRV, magnetic.

  11. Molecular structure and motion in zero field magnetic resonance

    Energy Technology Data Exchange (ETDEWEB)

    Jarvie, T.P.

    1989-10-01

    Zero field magnetic resonance is well suited for the determination of molecular structure and the study of motion in disordered materials. Experiments performed in zero applied magnetic field avoid the anisotropic broadening in high field nuclear magnetic resonance (NMR) experiments. As a result, molecular structure and subtle effects of motion are more readily observed.

  12. Magnetic resonance imaging of cleft palate

    Energy Technology Data Exchange (ETDEWEB)

    Naito, Yasushi; Tasaka, Yasuyuki; Honjo, Iwao; Nishimura, Kazumasa; Nakano, Yoshihisa

    1987-03-01

    Magnetic resonance imaging (MRI) of the nasopharynx and the eustachian tube was performed in five patients with cleft palate and compared with the results of those without this anomaly. Various degrees of deformity of the eustachian tube cartilage were found in cleft palate patients. The levator veli palatini muscles were situated more laterally in cleft palate patients than in normal subjects. Also, changes in the position of these muscles after palatoplasty were clearly depicted by MRI. Besides several autopsy reports, this is the first demonstration of the characteristic anomaly around the eustachian tube by a non-invasive method.

  13. Fetal fat measurement by magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Deans, H.E.; Smith, F.W.; Law, A.N. (Royal Infirmary, Aberdeen (UK)); Lloyd, D.J.; Sutherland, H.W. (Aberdeen Maternity Hospital (UK))

    1989-07-01

    A method to assess the average percentage of fetal fat with respect to other fetal tissue is described. This method was then used to assess the percentage of fat in 13 normal fetuses who had a magnetic resonance imaging (MRI) examination late in pregnancy (38-41 weeks). The scans of a further 13 fetuses of diabetic mothers and one case of intrauterine growth retardation (IUGR), all of whom had MRI examinations in the last 3 years, were reviewed and similar calculations were carried out. Whilst the percentage fat range in the normal group was large, it was still possible to discern a difference between the normal, diabetic and IUGR cases. (author).

  14. Interactive Real-time Magnetic Resonance Imaging

    DEFF Research Database (Denmark)

    Brix, Lau

    Real-time acquisition, reconstruction and interactively changing the slice position using magnetic resonance imaging (MRI) have been possible for years. However, the current clinical use of interactive real-time MRI is limited due to an inherent low spatial and temporal resolution. This PhD project...... with regard to optimal sampling strategy for detecting motion in four different anatomies on two different MRI scanner brands. A fully implemented interactive real-time MRI system was exploited in a group of healthy fetuses and proved its eligibility as an alternative diagnostic tool for fetal imaging...

  15. Cine magnetic resonance imaging of ocular motility.

    Science.gov (United States)

    Cadera, W; Viirre, E; Karlik, S

    1992-01-01

    We describe a technique of generation of a cine motion picture of ocular movements in a patient with Duane Type II exotropia. With the magnetic resonance scanning unit, multiple scans can be sequenced to give a graphic animation to the eyes as targets are fixated across the visual field. With this technique, we were able to clearly view the contractility of the extraocular muscles and note the changes in pulling directions of the muscles in this patient. The restriction of movement due to the cocontraction of the horizontal rectus muscles was readily apparent.

  16. Magnetic resonance imaging of cervical myelopathy

    Energy Technology Data Exchange (ETDEWEB)

    Chosa, Hirofumi; Yamano, Kouichirou; Ihara, Fumitoshi; Ueda, Yoshiaki; Maekawa, Masayuki; Tokuhisa, Ginichirou; Kuwano, Tadashi; Kamo, Yoshi; Nomura, Shigeharu (Kyushu Rosai Hospital, Fukuoka (Japan))

    1990-03-01

    Forty-three patients operated for cervical myelopathy were examined with a 1.5 T magnetic resonance imaging. Cord compression was demonstrated directly on the sagittal image in cases of cervical disc herniation, cervical spondylosis and O.P. L.L. Herniated disc material was seen positive on axial image. But factors of cord compression in cases of cervical spondylosis and O.P. L.L. were not clearly confirmed, so additional examinations such as myelogram, tomogram and CT was needed. (author).

  17. Magnetic Resonance Imaging of Thyroid and Parathyroid

    Directory of Open Access Journals (Sweden)

    Miguel GONZALO-DOMÍNGUEZ

    2017-05-01

    Full Text Available Introduction: The assessment of the thyroid and parathyroid pathology is usually achieved with ultrasounds. There are several systems of classification that are internationally accepted in neoplastic disease, such as TIRADS system, and there are well-defined patterns for ultrasound imaging in inflammatory disease. Material and methods: However, there are specific needs that require magnetic resonance imaging. We review the main indications of MRI in the evaluation of thyroid and parathyroid in 64 patients and determine which protocols are more appropriate and which sequences are better for a proper characterization. Results: Then we review the semiology obtained by this technique, making correlation with disease processes affecting these cervical structures.

  18. MRCP. Magnetic resonance cholangiopancreatography; MRCP. Magnetresonanzcholangiopankreatografie

    Energy Technology Data Exchange (ETDEWEB)

    Kinner, Sonja [Wisconsin-Madison Univ., Madison, WI (United States). Dept. of Radiology; Lauenstein, Thomas [Evangelisches Krankenhaus Duesseldorf (Germany). Radiologie

    2016-06-15

    Magnetic resonance cholangiopancreatography (MRCP) is a special MR technique to display and analyze the biliary tract and pancreatic ducts. MRCP sequences are equivalent to endoscopic retrograde cholangiopancreatography (ERCP) for diagnostic purposes due to technical developments of the classical T2 weighted MRCP sequences and the availability of contrast enhanced T1 weighted sequences. Therefore, MRCP plays a fundamental role in the diagnoses of hepatobliary and pancreatic diseases, which are presented in this review article as are technical details of sequence acquisitions and the underlying anatomy.

  19. Structural magnetic resonance imaging in epilepsy

    Energy Technology Data Exchange (ETDEWEB)

    Deblaere, Karel [Ghent University Hospital, Department of Neuroradiology, Ghent (Belgium); Ghent University Hospital, MR Department - 1K12, Ghent (Belgium); Achten, Eric [Ghent University Hospital, Department of Neuroradiology, Ghent (Belgium)

    2008-01-15

    Because of its sensitivity and high tissue contrast, magnetic resonance imaging (MRI) is the technique of choice for structural imaging in epilepsy. In this review the effect of using optimised scanning protocols and the use of high field MR systems on detection sensitivity is discussed. Also, the clinical relevance of adequate imaging in patients with focal epilepsy is highlighted. The most frequently encountered MRI findings in epilepsy are reported and their imaging characteristics depicted. Imaging focus will be on the diagnosis of hippocampal sclerosis and malformations of cortical development, two major causes of medically intractable focal epilepsy. (orig.)

  20. Developments in boron magnetic resonance imaging (MRI)

    Energy Technology Data Exchange (ETDEWEB)

    Schweizer, M.

    1995-11-01

    This report summarizes progress during the past year on maturing Boron-11 magnetic resonance imaging (MRI) methodology for noninvasive determination of BNCT agents (BSH) spatially in time. Three major areas are excerpted: (1) Boron-11 MRI of BSH distributions in a canine intracranial tumor model and the first human glioblastoma patient, (2) whole body Boron-11 MRI of BSH pharmacokinetics in a rat flank tumor model, and (3) penetration of gadolinium salts through the BBB as a function of tumor growth in the canine brain.

  1. Magnetic resonance spectroscopy studies in migraine

    Energy Technology Data Exchange (ETDEWEB)

    Montagna, P.; Cortelli, P.; Barbiroli, B. (Inst. of Medical Pathology, Univ. of Bologna (Italy))

    1994-06-01

    The authors describe the method of [sup 31]phosphorus magnetic resonance spectroscopy and review the results when it is applied to the study of brain and muscle energy metabolism in migraine subjects. Brain energy metabolism appears to be abnormal in all major subtypes of migraine when measured both during and between attacks. Impaired energy metabolism is also documented in skeletal muscle. It is suggested that migraine is associated with a generalized disorder of mitochondrial oxidative phosphorylation and that this may constitute a threshold for the triggering of migraine attacks. 47 refs., 10 figs., 3 tabs.

  2. Magnetic resonance in hearing loss and vertigo

    Directory of Open Access Journals (Sweden)

    Manuel Ángel MARTÍN-PÉREZ

    2017-03-01

    Full Text Available Introduction and objective: Hearing loss and vertiginous syndrome represent an important part of the otorhinolaryngology clinic. The role of the radiologist plays in their workup become fundamental. Studies using magnetic resonance imaging (MRI are essential to guide or give the diagnosis in these cases. Method: After performing a retrospective analysis of 456 MRI studies of patients with these symptoms, we conducted a review of the main pathologies recorded that can cause these symptoms. Results: We classify into vascular disorders and other variants, tumor pathology, malformations and inflammatory pathology; We also describe the most relevant findings on MRI and illustrated with examples of our center.

  3. Magnetic resonance imaging characteristics of granulomatous mastitis.

    Science.gov (United States)

    Chu, Amanda N; Seiler, Stephen J; Hayes, Jody C; Wooldridge, Rachel; Porembka, Jessica H

    Granulomatous mastitis (GM) is a benign chronic inflammatory condition of the breast. This study was performed to determine the utility of magnetic resonance imaging (MRI) in differentiating GM from malignancy. MRI findings in 12 women with clinical or histopathologically-proven GM were retrospectively reviewed. Non-mass enhancement on MRI was present in all 12 patients with clustered ring enhancement being the most common pattern (n=7, 58%). Architectural distortion (n=10, 83%), skin thickening (n=10, 83%) and focal skin enhancement (n=10, 83%) were also very common. MRI features of GM are often identical to features considered suspicious for malignancy on MRI. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Magnetic resonance imaging of acute pulmonary embolism

    Energy Technology Data Exchange (ETDEWEB)

    Fink, Christian; Schoenberg, Stefan O. [University Hospital Mannheim, Medical Faculty Mannheim-University of Heidelberg, Department of Clinical Radiology, Mannheim (Germany); Ley, Sebastian; Kauczor, H.U. [Deutsches Krebsforschungszentrum, Department of Radiology, Heidelberg (Germany); Reiser, Maximilian F. [University Hospitals Grosshadern, Ludwig-Maximilians-University of Munich, Department of Clinical Radiology, Munich (Germany)

    2007-10-15

    Pulmonary embolism (PE) is a very common and potentially life-threatening disease. In comparison with CT, the clinical relevance of magnetic resonance imaging (MRI) for the assessment of PE is low. Nevertheless, as there are some potential advantages of MRI over CT (e.g. radiation free method, better safety profile of MR contrast media, capability of functional imaging). In certain patient, groups MRI might therefore be considered as a valuable alternative in the assessment of suspected PE. This article reviews the relevant MRI techniques for the evaluation of PE and gives an overview of the current literature for contrast-enhanced MR angiography of PE. (orig.)

  5. Magnetic resonance images of chronic patellar tendinitis

    Energy Technology Data Exchange (ETDEWEB)

    Bodne, D.; Quinn, S.F.; Murray, W.T.; Cochran, C.; Bolton, T.; Rudd, S.; Lewis, K.; Daines, P.; Bishop, J.

    1988-01-01

    Chronic patellar tendinitis can be a frustrating diagnostic and therapeutic problem. This report evaluates seven tendons in five patients with chronic patellar tendinitis. The etiologies included 'jumper's knee' and Osgood-Schlatter disease. In all cases magnetic resonance images (MRI) showed thickening of the tendon. Some of the tendons had focal areas of thickening which helped establish the etiology. All cases had intratendinous areas of increased signal which, in four cases, proved to be chronic tendon tears. MRI is useful in evaluating chronic patellar tendinitis because it establishes the diagnosis, detects associated chronic tears, and may help determine appropriate rehabilitation. (orig.)

  6. Magnetic resonance-guided prostate interventions.

    Science.gov (United States)

    Haker, Steven J; Mulkern, Robert V; Roebuck, Joseph R; Barnes, Agnieska Szot; Dimaio, Simon; Hata, Nobuhiko; Tempany, Clare M C

    2005-10-01

    We review our experience using an open 0.5-T magnetic resonance (MR) interventional unit to guide procedures in the prostate. This system allows access to the patient and real-time MR imaging simultaneously and has made it possible to perform prostate biopsy and brachytherapy under MR guidance. We review MR imaging of the prostate and its use in targeted therapy, and describe our use of image processing methods such as image registration to further facilitate precise targeting. We describe current developments with a robot assist system being developed to aid radioactive seed placement.

  7. Hair product artifact in magnetic resonance imaging.

    Science.gov (United States)

    Chenji, Sneha; Wilman, Alan H; Mah, Dennell; Seres, Peter; Genge, Angela; Kalra, Sanjay

    2017-01-01

    The presence of metallic compounds in facial cosmetics and permanent tattoos may affect the quality of magnetic resonance imaging. We report a case study describing a signal artifact due to the use of a leave-on powdered hair dye. On reviewing the ingredients of the product, it was found to contain several metallic compounds. In lieu of this observation, we suggest that MRI centers include the use of metal- or mineral-based facial cosmetics or hair products in their screening protocols. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Contrast Agent in Magnetic Resonance Imaging

    DEFF Research Database (Denmark)

    Vu-Quang, Hieu

    2015-01-01

    Nanoparticles have been employed as contrast agent in magnetic resonance imaging (MRI) in order to improve sensitivity and accuracy in diagnosis. In addition, these contrast agents are potentially combined with other therapeutic compounds or near infrared bio-imaging (NIR) fluorophores to obtain...... theranostic or dual imaging purposes, respectively. There were two main types of MRI contrast agent that were synthesized during this PhD project including fluorine containing nanoparticles and magnetic nanoparticles. In regard of fluorine containing nanoparticles, there were two types contrast agent...... that were synthesized in project I and II. In project I, Poly (lactic-co-glycolic acid)-block-poly (ethylene glycol)-Folate Pefluorooctyl Bromide/Indocyanine green/ Doxorubicin (PLGA-PEG-Folate PFOB/ICG/Dox) has been formulated for the dual imaging NIR and 19F MRI as well as in the combination of Dox...

  9. Clinical applications of cardiovascular magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Marcu, C.B.; Beek, A.M.; Van Rossum, A.C. [Hospital of Saint Raphael, Cardiac Diagnostic Unit, New Haven, CT (United States)], E-mail: bogmarcu@pol.net

    2006-10-15

    Cardiovascular magnetic resonance imaging (MRI) has evolved from an effective research tool into a clinically proven, safe and comprehensive imaging modality. It provides anatomic and functional information in acquired and congenital heart disease and is the most precise technique for quantification of ventricular volumes, function and mass. Owing to its excellent interstudy reproducibility, cardiovascular MRI is the optimal method for assessment of changes in ventricular parameters after therapeutic intervention. Delayed contrast enhancement is an accurate and robust method used in the diagnosis of ischemic and nonischemic cardiomyopathies and less common diseases, such as cardiac sarcoidosis and myocarditis. First-pass magnetic contrast myocardial perfusion is becoming an alternative to radionuclide techniques for the detection of coronary atherosclerotic disease. In this review we outline the techniques used in cardiovascular MRI and discuss the most common clinical applications. (author)

  10. Nanoscale nuclear magnetic resonance with chemical resolution

    Science.gov (United States)

    Aslam, Nabeel; Pfender, Matthias; Neumann, Philipp; Reuter, Rolf; Zappe, Andrea; Fávaro de Oliveira, Felipe; Denisenko, Andrej; Sumiya, Hitoshi; Onoda, Shinobu; Isoya, Junichi; Wrachtrup, Jörg

    2017-07-01

    Nuclear magnetic resonance (NMR) spectroscopy is a key analytical technique in chemistry, biology, and medicine. However, conventional NMR spectroscopy requires an at least nanoliter-sized sample volume to achieve sufficient signal. We combined the use of a quantum memory and high magnetic fields with a dedicated quantum sensor based on nitrogen vacancy centers in diamond to achieve chemical shift resolution in 1H and 19F NMR spectroscopy of 20-zeptoliter sample volumes. We demonstrate the application of NMR pulse sequences to achieve homonuclear decoupling and spin diffusion measurements. The best measured NMR linewidth of a liquid sample was ~1 part per million, mainly limited by molecular diffusion. To mitigate the influence of diffusion, we performed high-resolution solid-state NMR by applying homonuclear decoupling and achieved a 20-fold narrowing of the NMR linewidth.

  11. Multiparametric magnetic resonance imaging findings of prostatic pure leiomyomas

    OpenAIRE

    Mussi, Thais Caldara; Costa,Yves Bohrer; Obara, Marcos Takeo; de Queiroz, Marcos Roberto Gomes; Garcia, Rodrigo Gobbo; Longo, José Antonio Domingos Cianciarulo; Lemos, Gustavo Caserta; Baroni, Ronaldo Hueb

    2016-01-01

    ABSTRACT Objective: To describe the imaging findings of prostatic tumors nonadenocarcinoma on multiparametric magnetic resonance imaging. Methods: A total of 200 patients underwented multiparametric magnetic resonance imaging of the prostate for screening for prostate cancer, from August 2013 to September 2014, followed by biopsy with ultrasound/magnetic resonance imaging fusion. Results: We found three pathologic proved cases of prostatic pure leiomyomas (0.02%) in our series and describe...

  12. [Cardiac magnetic resonance and uremic cardiomyopathy].

    Science.gov (United States)

    Di Lullo, L; Gorini, A; Rivera, R; De Pascalis, A; Bellasi, A; Russo, D; Barbera, V; Ronco, C; Balducci, A; Santoboni, A

    2014-01-01

    Cardiovascular disease (CV) represents the main risk factor for morbidity and mortality in chronic kidney disease (CKD) patients. Large epidemiological studies have shown direct association between severity of CKD and CV event rates. Although patients with end-stage renal disease (ESRD), including dialysis ones, are at greater CV risk, cardiovascular involvement is already evident at the early stages of CKD. End-stage CKD is characterized conventional atherosclerotic risk factor but they cannot account for CV risk as reflected in high rates of sudden cardiac death, heart failure and myocardial infarction. Non-atherosclerotic processes, including left ventricular hypertrophy and fibrosis, mostly account for the excess risk of CV. Employment of cardiac magnetic resonance (CMR) in CKD has brought an improved understanding of the adverse CV changes, known as uremic cardiomyopathy. It is due to ability of cardiac magnetic resonance to provide a comprehensive non - invasive examination of cardiac structure and function, arterial function, myocardial tissue characterization (T1 mapping and inversion recovery imaging), and myocardial metabolic function (spectroscopy).

  13. Magnetic Resonance Microscopy of the Lung

    Science.gov (United States)

    Johnson, G. Allan

    1999-11-01

    The lung presents both challenges and opportunities for study by magnetic resonance imaging (MRI). The technical challenges arise from respiratory and cardiac motion, limited signal from the tissues, and unique physical structure of the lung. These challenges are heightened in magnetic resonance microscopy (MRM) where the spatial resolution may be up to a million times higher than that of conventional MRI. The development of successful techniques for MRM of the lung present enormous opportunities for basic studies of lung structure and function, toxicology, environmental stress, and drug discovery by permitting investigators to study this most essential organ nondestructively in the live animal. Over the last 15 years, scientists at the Duke Center for In Vivo Microscopy have developed techniques for MRM in the live animal through an interdisciplinary program of biology, physics, chemistry, electrical engineering, and computer science. This talk will focus on the development of specialized radiofrequency coils for lung imaging, projection encoding methods to limit susceptibility losses, specialized support structures to control and monitor physiologic motion, and the most recent development of hyperpolarized gas imaging with ^3He and ^129Xe.

  14. Magnetic resonance imaging of the bone marrow

    Energy Technology Data Exchange (ETDEWEB)

    Baur-Melnyk, Andrea (ed.) [Klinikum der Univ. Muenchen (Germany). Inst. fuer Klinische Radiologie

    2013-08-01

    The first book devoted to MRI of the bone marrow. Describes the MRI appearances of normal bone marrows and the full range of bone marrow disorders. Discusses the role of advanced MRI techniques and contrast enhancement. On account of its unrivalled imaging capabilities and sensitivity, magnetic resonance imaging (MRI) is considered the modality of choice for the investigation of physiologic and pathologic processes affecting the bone marrow. This book describes the MRI appearances of both the normal bone marrow, including variants, and the full range of bone marrow disorders. Detailed discussion is devoted to malignancies, including multiple myeloma, lymphoma, chronic myeloproliferative disorders, leukemia, and bone metastases. Among the other conditions covered are benign and malignant compression fractures, osteonecrosis, hemolytic anemia, Gaucher's disease, bone marrow edema syndrome, trauma, and infective and non-infective inflammatory disease. Further chapters address the role of MRI in assessing treatment response, the use of contrast media, and advanced MRI techniques. Magnetic Resonance Imaging of the Bone Marrow represents an ideal reference for both novice and experienced practitioners.

  15. Magnetic resonance imaging of granular materials

    Science.gov (United States)

    Stannarius, Ralf

    2017-05-01

    Magnetic Resonance Imaging (MRI) has become one of the most important tools to screen humans in medicine; virtually every modern hospital is equipped with a Nuclear Magnetic Resonance (NMR) tomograph. The potential of NMR in 3D imaging tasks is by far greater, but there is only "a handful" of MRI studies of particulate matter. The method is expensive, time-consuming, and requires a deep understanding of pulse sequences, signal acquisition, and processing. We give a short introduction into the physical principles of this imaging technique, describe its advantages and limitations for the screening of granular matter, and present a number of examples of different application purposes, from the exploration of granular packing, via the detection of flow and particle diffusion, to real dynamic measurements. Probably, X-ray computed tomography is preferable in most applications, but fast imaging of single slices with modern MRI techniques is unmatched, and the additional opportunity to retrieve spatially resolved flow and diffusion profiles without particle tracking is a unique feature.

  16. Clinical application of functional magnetic resonance imaging

    CERN Document Server

    Alwatban, A Z W

    2002-01-01

    The work described in this thesis was carried out at the Magnetic Resonance Centre of the University of Nottingham during the time from May 1998 to April 2001, and is the work of the except where indicated by reference. The main source of signal changes in functional magnetic resonance imaging (fMRJ) is the fluctuation of paramagnetic deoxyhaemoglobin in the venous blood during different states of functional performance. For the work of this thesis, fMRI studies were carried out using a 3 T MR system with an echo planar imaging (EPI) pulse sequence. Hearing research utilising fMRI has been previously reported in normal subjects. Hearing fMRI is normally performed by stimulating the auditory cortex via an acoustic task presentation such as music, tone, etc. However, performing the same research on deaf subjects requires special equipment to be designed to allow direct stimulation of the auditory nerve. In this thesis, a new method of direct electrical stimulation of the auditory nerve is described that uses a ...

  17. Magnetic resonance imaging of fetal pelvic cysts.

    Science.gov (United States)

    Archontaki, Styliani; Vial, Yvan; Hanquinet, Sylviane; Meuli, Reto; Alamo, Leonor

    2016-12-01

    The detection of fetal anomalies has improved in the last years as a result of the generalization of ultrasound pregnancy screening exams. The presence of a cystic imaging in the fetal pelvis is a relatively common finding, which can correspond to a real congenital cystic lesion or result from the anomalous liquid accumulation in a whole pelvic organ, mainly the urinary bladder, the uterus, or the vagina. In selected cases with poor prognosis and/or inconclusive echographic findings, magnetic resonance may bring additional information in terms of the characterization, anatomical location, and real extension of the pathology. This pictorial essay describes the normal pelvic fetal anatomy, as well as the most common pelvic cysts. It also describes the causes of an anomalous distension of the whole pelvic organs detected in utero, with emphasis on prenatal magnetic resonance imaging exams. Moreover, it proposes practical teaching points to reduce the differential diagnosis of these lesions based on the sex of the fetus, the division of the pelvis in anatomical spaces, and the imaging findings of the pathology. Finally, it discusses the real utility of complementary MRI.

  18. Magnetic resonance spectroscopy in cancer diagnostics

    Directory of Open Access Journals (Sweden)

    Ana Margarida Abrantes

    2011-12-01

    Full Text Available Magnetic resonance spectroscopy (MRS is one of the most powerful analytical techniques, being frequently used to derive physical, chemical, electronic, and structural information about molecules. Considering its potentialities and its evolution as cell/tissue response predictor, it can be used to detect changes in the tumor pathophysiology before, during, and after treatment. Of particular relevance to this analysis, due to its higher sensitivity, is proton magnetic resonance spectroscopy (1H-MRS either applied directly in vivo or by using tumor biopsies and high-rotation magic angle spinning (HRMAS. Several metabolites have been quantified in several tumors, including creatine and phosphocreatine, choline, lactate and myoinositol, and used for distinguishing different cancer types. Several advantages characterize this technique including swiftness and ability to support the characterization of tumoral lesions on the basis of their biochemical composition, which may provide additional diagnostic and prognostic information as an adjunct to routine histological assessment. Many tumors have already been studied by 1H-MRS, and there is growing interest in studying others in order to establish extended metabolite databases which could help in their identification and characterization.

  19. Magnetic resonance imaging findings in adnexial torsion

    Directory of Open Access Journals (Sweden)

    Ronald Meira Castro Trindade

    2010-03-01

    Full Text Available Adnexial torsion is an unusual event, but a major cause of abdominal pain in women. It is often associated with ovarian tumor or cyst, but can occur in normal ovaries, especially in children. The twisting of adnexial structures may involve the ovary or tube, but frequently affects both. In most cases, it is unilateral, with slight predilection for the right side. In imaging findings, increased ovarian volume and adnexial masses are observed, with reduced or absent vascularization. In cases of undiagnosed or untreated complete twist, hemorrhagic necrosis may occur leading to complications; in that, peritonitis is the most frequent. Early diagnosis helps preventing irreversible damage with conservative treatment, thereby saving the ovary. Limitations in performing physical examination, possible inconclusive results in ultrasound and exposure to radiation in computed tomography makes magnetic resonance imaging a valuable tool in emergency assessment of gynecological diseases. The objective of this study was to report two confirmed cases of adnexial twist, emphasizing the contribution of magnetic resonance imaging in the diagnosis of this condition.

  20. Magnetic resonance imaging findings in adnexial torsion

    Energy Technology Data Exchange (ETDEWEB)

    Trindade, Ronald Meira Castro; Quadros, Marianne Siquara de [Hospital Albert Einstein, Sao Paulo, SP (Brazil). Instituto de Ensino e Pesquisa], e-mail: rtrindade@einstein.br; Baroni, Ronaldo Hueb; Rosemberg, Michelle; Racy, Marcelo de Castro Jorge; Tachibana, Adriano [Hospital Albert Einstein, Sao Paulo, SP (Brazil); Funari, Marcelo Buarque de Gusmao [Hospital Albert Einstein, Sao Paulo, SP (Brazil). Imaging Service

    2010-01-15

    Adnexial torsion is an unusual event, but a major cause of abdominal pain in women. It is often associated with ovarian tumor or cyst, but can occur in normal ovaries, especially in children. The twisting of adnexial structures may involve the ovary or tube, but frequently affects both. In most cases, it is unilateral, with slight predilection for the right size. In imaging findings, increased ovarian volume and adnexial masses are observed, with reduced or absent vascularisation. In cases of undiagnosed or untreated complete twist, hemorrhagic necrosis may occur leading to complications; in that, peritonitis is the most frequent. Early diagnosis helps preventing irreversible damage with conservative treatment, thereby saving the ovary. Limitations in performing physical examination, possible inconclusive results in ultrasound and exposure to radiation in computed tomography makes magnetic resonance imaging a valuable tool in emergency assessment of gynecological diseases. The objective of this study was to report two confirmed cases of adnexial twist, emphasizing the contribution of magnetic resonance imaging in the diagnosis of this condition. (author)

  1. Resonances and dipole moments in dielectric, magnetic, and magnetodielectric cylinders

    DEFF Research Database (Denmark)

    Dirksen, A.; Arslanagic, Samel; Breinbjerg, Olav

    2011-01-01

    An eigenfunction solution to the problem of plane wave scattering by dielectric, magnetic, and magnetodielectric cylinders is used for a systematic investigation of their resonances. An overview of the resonances with electric and magnetic dipole moments, needed in, e.g., the synthesis of metamat......An eigenfunction solution to the problem of plane wave scattering by dielectric, magnetic, and magnetodielectric cylinders is used for a systematic investigation of their resonances. An overview of the resonances with electric and magnetic dipole moments, needed in, e.g., the synthesis...

  2. Non-contrast-enhanced magnetic resonance angiography: techniques and applications.

    Science.gov (United States)

    Blankholm, Anne Dorte; Ringgaard, Steffen

    2012-01-01

    Non-contrast-enhanced magnetic resonance angiography has gained renewed interest since the discovery of the association between gadolinium-based contrast agents and nephrogenic systemic fibrosis. The following article is an overview of the different magnetic resonance angiography sequences, the technical possibilities and new developments. Clinical options and recent advancements will be highlighted, and recommendations for non-contrast-enhanced magnetic resonance angiography techniques in different anatomical regions will be given. Furthermore, the authors seek to predict the future of non-contrast-enhanced magnetic resonance angiography, with special focus on patients at risk.

  3. Structural Magnetic Resonance Imaging of the Adolescent Brain

    National Research Council Canada - National Science Library

    GIEDD, JAY N

    2004-01-01

    A bstract : Magnetic resonance imaging (MRI) provides accurate anatomical brain images without the use of ionizing radiation, allowing longitudinal studies of brain morphometry during adolescent development...

  4. Bose Operator Expansions of Tensor Operators in the Theory of Magnetism

    DEFF Research Database (Denmark)

    Lindgård, Per-Anker; Kowalska, A.

    1976-01-01

    For pt.I see ibid., vol.7, p.1523 (1974). The matching of matrix element method is used to find a new self-consistent Bose operator expansion for tensor operators in spin systems with isotropic exchange interaction plus anisotropy. Tables are given for all tensor operators relevant for cubic...

  5. Spin Resonance and Magnetic Order in an Unconventional Superconductor

    Science.gov (United States)

    Mazzone, D. G.; Raymond, S.; Gavilano, J. L.; Steffens, P.; Schneidewind, A.; Lapertot, G.; Kenzelmann, M.

    2017-11-01

    Unconventional superconductivity in many materials is believed to be mediated by magnetic fluctuations. It is an open question how magnetic order can emerge from a superconducting condensate and how it competes with the magnetic spin resonance in unconventional superconductors. Here we study a model d -wave superconductor that develops spin-density wave order, and find that the spin resonance is unaffected by the onset of static magnetic order. This result suggests a scenario, in which the resonance in Nd0.05Ce0.95CoIn5 is a longitudinal mode with fluctuating moments along the ordered magnetic moments.

  6. Spin Resonance and Magnetic Order in an Unconventional Superconductor.

    Science.gov (United States)

    Mazzone, D G; Raymond, S; Gavilano, J L; Steffens, P; Schneidewind, A; Lapertot, G; Kenzelmann, M

    2017-11-03

    Unconventional superconductivity in many materials is believed to be mediated by magnetic fluctuations. It is an open question how magnetic order can emerge from a superconducting condensate and how it competes with the magnetic spin resonance in unconventional superconductors. Here we study a model d-wave superconductor that develops spin-density wave order, and find that the spin resonance is unaffected by the onset of static magnetic order. This result suggests a scenario, in which the resonance in Nd_{0.05}Ce_{0.95}CoIn_{5} is a longitudinal mode with fluctuating moments along the ordered magnetic moments.

  7. Ferromagnetic resonance of particulate magnetic recording tapes

    Science.gov (United States)

    Netzelmann, U.

    1990-08-01

    The room-temperature ferromagnetic resonance (FMR) spectra of γ-Fe2O3, CrO2, and barium ferrite particulate magnetic recording tapes have been measured at microwave frequencies of 9.35 and 35 GHz for various orientations of the static and high-frequency magnetic fields with respect to the tape. For CrO2 tapes, the influence of the width of the angular distribution of the particle orientations on the FMR spectra has been studied from the nearly isotropic case up to the highly oriented case. Hysteretic behavior for a CrO2 tape as well as the effect of tape calendering for a γ-Fe2O3 tape has been observed by FMR. Experimental results are found to be in reasonable agreement with results of theoretical calculations based on a model of an ellipsoidal single-domain particle with both shape and magnetocrystalline anisotropy. Magnetostatic interaction inside the magnetic film has been introduced by expressing the total magnetostatic energy as a combination of a part dependent on particle shape and a part dependent on the shape of the tape. As a result of a comparison of experimental data with calculated data from the model, the magnetocrystalline easy axis of the CrO2 particles is found to be parallel with the particle axis.

  8. Studies of the heart using magnetic resonance.

    Science.gov (United States)

    Longmore, D; Forbat, S

    1992-01-01

    Cardiovascular medicine is based on high-technology management of end-stage disease. Preventive medicine is preferable but, before magnetic resonance (MR), there was no noninvasive, safe, repeatable method of detecting occlusive vascular disease, which accounts for more deaths than any other disease at a presymptomatic stage. Demographic and animal studies show that occlusive vascular disease is not a normal aging process and is reversible. There was no method of monitoring the efficacy of preventive and therapeutic measures other than long, expensive, and sometimes inconclusive clinical trials. The rate of precession of atomic nuclei in a magnetic field is related to field strength. Creating a unique magnetic field in each volume of interest allows analysis of emitted radio signals to produce an image containing information about movement and local biochemical environments. MR produces accurate high resolution anatomical images and functional information including blood flow. It is already established as a method of choice in clinical cardiology for congenital heart disease and aortic disease. It is becoming established as a method of evaluating cardiovascular-active drugs, and in the future MR will be used for diagnosis and as a population-screening instrument for all cardiovascular disease including coronary artery disease.

  9. Development of techniques in magnetic resonance and structural studies of the prion protein

    Energy Technology Data Exchange (ETDEWEB)

    Bitter, Hans-Marcus L. [Univ. of California, Berkeley, CA (United States)

    2000-07-01

    Magnetic resonance is the most powerful analytical tool used by chemists today. Its applications range from determining structures of large biomolecules to imaging of human brains. Nevertheless, magnetic resonance remains a relatively young field, in which many techniques are currently being developed that have broad applications. In this dissertation, two new techniques are presented, one that enables the determination of torsion angles in solid-state peptides and proteins, and another that involves imaging of heterogenous materials at ultra-low magnetic fields. In addition, structural studies of the prion protein via solid-state NMR are described. More specifically, work is presented in which the dependence of chemical shifts on local molecular structure is used to predict chemical shift tensors in solid-state peptides with theoretical ab initio surfaces. These predictions are then used to determine the backbone dihedral angles in peptides. This method utilizes the theoretical chemicalshift tensors and experimentally determined chemical-shift anisotropies (CSAs) to predict the backbone and side chain torsion angles in alanine, leucine, and valine residues. Additionally, structural studies of prion protein fragments are described in which conformationally-dependent chemical-shift measurements were made to gain insight into the structural differences between the various conformational states of the prion protein. These studies are of biological and pathological interest since conformational changes in the prion protein are believed to cause prion diseases. Finally, an ultra-low field magnetic resonance imaging technique is described that enables imaging and characterization of heterogeneous and porous media. The notion of imaging gases at ultra-low fields would appear to be very difficult due to the prohibitively low polarization and spin densities as well as the low sensitivities of conventional Faraday coil detectors. However, Chapter 5 describes how gas imaging

  10. Magnetic Nanoparticles Aggregation in Magnetic Gel Studied by Electron Magnetic Resonance (EMR

    Directory of Open Access Journals (Sweden)

    Olga N. Sorokina

    2012-04-01

    Full Text Available Aggregation of magnetic nanoparticles immobilized in polymer gels was studied by ferromagnetic resonance and paramagnetic sensor techniques. Ferromagnetic resonance spectra of magnetic gels prepared in the presence of external magnetic field of 1.5 kG were compared to the spectra of gels synthesized in the absence of a magnetic field. Application of a magnetic field led to formation of linear aggregates of magnetic particles in the polymer matrix. The aggregates did not come apart after the field was switched off. The fraction of aggregated particles (of 62(6% and aspect ratio (elongation of the aggregates (12.6(1.3 was determined using paramagnetic sensor technique.

  11. Magnetic resonance imaging of intervertebral disc degeneration

    Energy Technology Data Exchange (ETDEWEB)

    Maeda, Hiroshi; Noguchi, Masao (Kitakyushu City Yahata Hospital, Fukuoka (Japan)); Kira, Hideaki; Fujiki, Hiroshi; Shimokawa, Isao; Hinoue, Kaichi

    1993-02-01

    The aim of this study was to correlate the degree of lumbar intervertebral disc degeneration with findings of magnetic resonance imaging (MRI). Seventeen autopsied (from 7 patients) and 21 surgical (from 20 patients) intervertebral discs were used as specimens for histopathological examination. In addition, 21 intervertebral discs were examined on T2-weighted images. Histopathological findings from both autopsied and surgical specimens were well correlated with MRI findings. In particular, T2-weighted images reflected increased collagen fibers and rupture within the fibrous ring accurately. However, when severely degenerated intervertebral discs and hernia protruding the posterior longitudinal ligament existed, histological findings were not concordant well with T2-weighted images. Morphological appearances of autopsy specimens, divided into four on T2-weighted images, were well consistent with histological degeneration. This morphological classification, as shown on T2-weighted images, could also be used in the evaluation of intervertebral disc degeneration. (N.K.).

  12. Magnetic resonance imaging of facial muscles

    Energy Technology Data Exchange (ETDEWEB)

    Farrugia, M.E. [Department of Clinical Neurology, University of Oxford, Radcliffe Infirmary, Oxford (United Kingdom)], E-mail: m.e.farrugia@doctors.org.uk; Bydder, G.M. [Department of Radiology, University of California, San Diego, CA 92103-8226 (United States); Francis, J.M.; Robson, M.D. [OCMR, Department of Cardiovascular Medicine, University of Oxford, John Radcliffe Hospital, Oxford (United Kingdom)

    2007-11-15

    Facial and tongue muscles are commonly involved in patients with neuromuscular disorders. However, these muscles are not as easily accessible for biopsy and pathological examination as limb muscles. We have previously investigated myasthenia gravis patients with MuSK antibodies for facial and tongue muscle atrophy using different magnetic resonance imaging sequences, including ultrashort echo time techniques and image analysis tools that allowed us to obtain quantitative assessments of facial muscles. This imaging study had shown that facial muscle measurement is possible and that useful information can be obtained using a quantitative approach. In this paper we aim to review in detail the methods that we applied to our study, to enable clinicians to study these muscles within the domain of neuromuscular disease, oncological or head and neck specialties. Quantitative assessment of the facial musculature may be of value in improving the understanding of pathological processes occurring within facial muscles in certain neuromuscular disorders.

  13. Magnetic resonance imaging in acute physeal injuries

    Energy Technology Data Exchange (ETDEWEB)

    White, P.G. [Dept. of Radiology, McMaster Univ. Medical Centre, Hamilton, ON (Canada); Mah, J.Y. [Dept. of Orthopedics, McMaster Univ. Medical Centre, Hamilton, ON (Canada); Friedman, L. [Dept. of Radiology, McMaster Univ. Medical Centre, Hamilton, ON (Canada)

    1994-11-01

    Magnetic resonance imaging (MRI) permits noninvasive evaluation of the cartilage of the growth plate and epiphysis. This paper reports three cases where MRI was used to supplement conventional radiography in the assessment of acute physeal injuries. In the first patient, MRI was used for postoperative assessment of a radial neck fracture, avoiding further surgical exploration. In the second case, MRI was compared with ultrasonography in the diagnosis of proximal humeral epiphyseal separation in a neonate. In the third case, MRI and computed tomography were compared in evaluation of a Salter-Harris type 4 distal femur fracture. In all cases MRI was diagnostic. MRI is the investigation of choice in acute complex physeal injuries, and is particularly appropriate for use prior to the appearance of the secondary ossification center. (orig.)

  14. Cryogenic Preamplifiers for Magnetic Resonance Imaging

    DEFF Research Database (Denmark)

    Johansen, Daniel H.; Sanchez-Heredia, Juan D.; Petersen, Jan R.

    2018-01-01

    Pursuing the ultimate limit of detection in magnetic resonance imaging (MRI) requires cryogenics to decrease the thermal noise of the electronic circuits. As cryogenic coils for MRI are slowly emerging cryogenic preamplifiers are required to fully exploit their potential. A cryogenic preamplifier...... operated at 77 K is designed and implemented for C imaging at 3 T (32.13 MHz), using off-the-shelves components. The design is based on a high electron mobility transistor (ATF54143) in a common source configuration. Required auxiliary circuitry for optimal cryogenic preamplifier performance is also...... presented consisting of a voltage regulator (noise free supply voltage and optimal power consumption), switch, and trigger (for active detuning during transmission to protect the preamplifier). A gain of 18 dB with a noise temperature of 13.7 K is achieved. Performing imaging experiments in a 3 T scanner...

  15. [Magnetic resonance tomography: potentials of molecular imaging].

    Science.gov (United States)

    Hiller, Karl-Heinz; Faber, Cornelius; Neuberger, Thomas; Köhler, Sascha; Stroh, Albrecht; Zimmer, Claus; Jakob, Peter

    2005-01-01

    Molecular imaging is "the in-vivo characterization and measurement of biological processes at the cellular and molecular level" and allows the imaging of molecular abnormalities associated with diseases long before morphological changes can be detected. At present, the use of magnetic resonance imaging (MRI) for molecular and cellular imaging is rapidly increasing. MRI is a very attractive candidate, since current MRI protocols already provide anatomic, functional, and biochemical information of excellent image quality and with high spatial resolution. Combining this high spatial resolution/high contrast imaging modality with specific MRI contrast imaging agents for molecular imaging is currently the focus of research in many laboratories worldwide. This paper summarizes the rationale for molecular MRI imaging and describes the basic features of modern molecular imaging strategies with MRI. Finally, a special focus is given to the growing field of applications, e.g., stem cell imaging, imaging of apoptosis, plaques, and other biological targets of interest.

  16. Magnetic resonance imaging for cardiac tumors

    Energy Technology Data Exchange (ETDEWEB)

    Niwa, Koichiro; Tashima, Kazuyuki; Okajima, Yoshitomo; Nakajima, Hiromichi; Terai, Masaru; Nakajima, Hironori; Harada, Tsutomu; Ishida, Yoshikazu.

    1988-09-01

    We performed magnetic resonance imaging (MRI) in 4 patients with cardiac tumor (1 with rhabdomyoma, 1 with left atrial myxoma, and 2 with tumor of the left ventricular wall) for morphological evaluation of the tumor. ECG-gated MRI was performed by the spin echo imaging technique using a superconducting MRI system operating at 0.5 tesla. Spatial extension of the tumor was clearly demonstrated in all the patients. Gadolinium-DTPA (Gd-DTPA), was used in the 2 patients with tumor of the left ventricular myocardium to enhance the contrast, and allowed clear visualization of the tumor. These findings show the usefulness of MRI and MRI with Gd-DTPA for morphological evaluation of cardiac tumor.

  17. Magnetic resonance urography by virtual reality modelling.

    Science.gov (United States)

    Beigi, Navid; Sangild, Thomas; Terkildsen, Søren Vorre; Deding, Dorthe; Stødkilde-Jørgensen, Hans; Pedersen, Michael

    2003-01-01

    The purpose of this study was to create a 3D visualization of the urinary tract by a novel virtual reality approach, and to evaluate the usefulness of this method for papillary classification as compared with 2D urogram obtained by maximum intensity projection (MIP). In one healthy pig, magnetic resonance urography was performed using a T1-weighted 3D gradient echo pulse sequence. Post-processing was performed by means of an MIP algorithm and by using 3D virtual reality modelling, followed by manual classification of papillae as being either simple or compound. The 2D MIP urogram demonstrated 6 simple and 6 compound papillae, whereas the 3D urogram demonstrated 5 simple and 7 compound papillae. In both urograms, some papillae were unsuccessfully classified. The possibility of using virtual reality devices allowed 3D rotation and offered additional diagnostic information. However, further studies should reveal its feasibility in diseased kidneys.

  18. Two-dimensional nuclear magnetic resonance petrophysics.

    Science.gov (United States)

    Sun, Boqin; Dunn, Keh-Jim

    2005-02-01

    Two-dimensional nuclear magnetic resonance (2D NMR) opens a wide area for exploration in petrophysics and has significant impact to petroleum logging technology. When there are multiple fluids with different diffusion coefficients saturated in a porous medium, this information can be extracted and clearly delineated from CPMG measurements of such a system either using regular pulsing sequences or modified two window sequences. The 2D NMR plot with independent variables of T2 relaxation time and diffusion coefficient allows clear separation of oil and water signals in the rocks. This 2D concept can be extended to general studies of fluid-saturated porous media involving other combinations of two or more independent variables, such as chemical shift and T1/T2 relaxation time (reflecting pore size), proton population and diffusion contrast, etc.

  19. Magnetic resonance imaging of ovarian cystic tumor

    Energy Technology Data Exchange (ETDEWEB)

    Wakabayashi, Yukari; Kawana, Kouji; Iiyama, Motoko; Abe, Kimihiko; Yachida, Meri; Amino, Saburou; Kotake, Fumio

    1988-11-01

    Seventeen cases with cystic ovarian tumors were examined with both magnetic resonance imaging (MRI) and CT scanning. The contents of the cysts were analyzed as for protein, fat, and iron. The intensity patterns of the cystic lesion were not directly related to the amount of protein, fat, nor iron. But an for the cystadenomas, protein concentration are the most responsible for their intensities, and as for the dermoid cysts, fat are the most responsible for. And in endemetrial cysts, it seems that variable amount of protein, fat, and iron make the unique intensity patterns. MRI was superior to CT in characterizing cyts especially for cystadenoma and endmetorial cysts. And with much more case studies, relationship between protein concentration and intensities will be proved.

  20. [Magnetic resonance urography in pediatric urology].

    Science.gov (United States)

    Schindele, D; Furth, C; Liehr, U B; Porsch, M; Baumunk, D; Janitzky, A; Wendler, J J; Genseke, P; Ricke, J; Schostak, M

    2012-12-01

    Magnetic resonance urography (MRU) provides high resolution imaging of the urogenital system and the use of paramagnetic contrast agents enables a functional depiction. This review summarizes existing data concerning this diagnostic procedure in pediatric urology. A systematic search and assessment of the literature was performed.A total of 12 studies were reviewed in detail. In mostly small study populations a great heterogeneity concerning methodology, use of comparative examinations and standards of reference was noted. Besides the quality of anatomical imaging, the functional study of renal excretory function and differential renal function was also assessed. Only a few studies performed statistical analyses.The authors' rating of MRU was mostly positive. Due to methodical weaknesses, lack of independent standards of reference and statistical analyses the overall level of evidence was low. Further high quality studies will be necessary to assess the value of MRU for the diagnostic workup in pediatric urology.

  1. Magnetic resonance imaging of cerebrotendinous xanthomatosis

    Energy Technology Data Exchange (ETDEWEB)

    Tai, K.S.; Brockwell, J.; Chan, F.L.; Janus, E.D.; Lam, K.S.L.

    1995-02-01

    Cerebrotendinous xanthomatosis (CTX) is a rare genetic disorder in which cholestanol and cholesterol accumulate in the nervous system and other tissues. It has an autosomal recessive mode of inheritance. Most patients are of low intelligence with poor school performance. Specific clinical manifestations include xanthomas of the tendons. Furthermore, patients develop cataracts and a slowly progressive cerebellar ataxia. There is slight mental deterioration. Death usually occurs in the sixth or seventh decade and is often due to unrelated causes. Plasma cholesterol levels are normal or only moderately elevated. The pattern of serum lipids is normal, and only serum cholestanol is significantly increased. Radiological features of the disease are infrequently described in the literature. We report a case of CTX in which magnetic resonance imaging (MRI) was used to image the brain, lumbar spine and the tendinous xanthomas of the lower limbs. 15 refs., 5 figs.

  2. Magnetic resonance imaging of pancreatitis: An update

    Science.gov (United States)

    Manikkavasakar, Sriluxayini; AlObaidy, Mamdoh; Busireddy, Kiran K; Ramalho, Miguel; Nilmini, Viragi; Alagiyawanna, Madhavi; Semelka, Richard C

    2014-01-01

    Magnetic resonance (MR) imaging plays an important role in the diagnosis and staging of acute and chronic pancreatitis and may represent the best imaging technique in the setting of pancreatitis due to its unmatched soft tissue contrast resolution as well as non-ionizing nature and higher safety profile of intravascular contrast media, making it particularly valuable in radiosensitive populations such as pregnant patients, and patients with recurrent pancreatitis requiring multiple follow-up examinations. Additional advantages include the ability to detect early forms of chronic pancreatitis and to better differentiate adenocarcinoma from focal chronic pancreatitis. This review addresses new trends in clinical pancreatic MR imaging emphasizing its role in imaging all types of acute and chronic pancreatitis, pancreatitis complications and other important differential diagnoses that mimic pancreatitis. PMID:25356038

  3. Cardiovascular magnetic resonance in hypertrophic cardiomyopathy

    Energy Technology Data Exchange (ETDEWEB)

    Shiozaki, Afonso Akio; Parga, Jose Rodrigues; Arteaga, Edmundo; Rochitte, Carlos Eduardo [Sao Paulo Univ. (USP), SP (Brazil). Instituto do Coracao. Setor de Tomografia Computarizada e Ressonancia Magnetica Cardiovascular]. E-mail: rochitte@incor.usp.br; Kim, Raymond J. [Duke Cardiovascular Magnetic Resonance Center, Durham, NC (United States); Tassi, Eduardo Marinho [Diagnosticos da America S.A., Rio de Janeiro, RJ (Brazil). Sector of Cardiovascular Magnetic Resonance and Computed Tomography

    2007-03-15

    Hypertrophic cardiomyopathy (HCM) is the most frequent genetic cardiac disease that causes sudden death in young people, with an incidence of 1:500 adults. The routinely used criteria for worst prognosis have limited sensitivity and specificity. Thus, the estimated risk of evolving to dilated cardiomyopathy or sudden death is somewhat inaccurate, leading to management uncertainty of HCM patients. Therefore, an accurate noninvasive method for the diagnosis of HCM with prognostic value is of great importance. In the last years, Cardiovascular Magnetic Resonance (CMR) emerged not only as a diagnostic tool, but also as a study with prognostic values, by characterizing myocardial fibrosis with great accuracy in HCM patients. Additionally, CMR identifies the types of hypertrophy, analyses the ventricular function, estimates the intraventricular gradient and allows the determination of differential diagnosis. Moreover, CMR can uniquely access myocardial fibrosis in HCM. (author)

  4. Magnetic Resonance Imaging in Amyotrophic Lateral Sclerosis

    Directory of Open Access Journals (Sweden)

    Katja Kollewe

    2012-01-01

    Full Text Available Amyotrophic lateral sclerosis (ALS is a rapidly progressing neurodegenerative disorder which is incurable to date. As there are many ongoing studies with therapeutic candidates, it is of major interest to develop biomarkers not only to facilitate early diagnosis but also as a monitoring tool to predict disease progression and to enable correct randomization of patients in clinical trials. Magnetic resonance imaging (MRI has made substantial progress over the last three decades and is a practical, noninvasive method to gain insights into the pathology of the disease. Disease-specific MRI changes therefore represent potential biomarkers for ALS. In this paper we give an overview of structural and functional MRI alterations in ALS with the focus on task-free resting-state investigations to detect cortical network failures.

  5. Chest magnetic resonance imaging: a protocol suggestion

    Directory of Open Access Journals (Sweden)

    Bruno Hochhegger

    2015-12-01

    Full Text Available Abstract In the recent years, with the development of ultrafast sequences, magnetic resonance imaging (MRI has been established as a valuable diagnostic modality in body imaging. Because of improvements in speed and image quality, MRI is now ready for routine clinical use also in the study of pulmonary diseases. The main advantage of MRI of the lungs is its unique combination of morphological and functional assessment in a single imaging session. In this article, the authors review most technical aspects and suggest a protocol for performing chest MRI. The authors also describe the three major clinical indications for MRI of the lungs: staging of lung tumors; evaluation of pulmonary vascular diseases; and investigation of pulmonary abnormalities in patients who should not be exposed to radiation.

  6. Quantum information processing and nuclear magnetic resonance

    CERN Document Server

    Cummins, H K

    2001-01-01

    as spectrometer pulse sequence programs. Quantum computers are information processing devices which operate by and exploit the laws of quantum mechanics, potentially allowing them to solve problems which are intractable using classical computers. This dissertation considers the practical issues involved in one of the more successful implementations to date, nuclear magnetic resonance (NMR). Techniques for dealing with systematic errors are presented, and a quantum protocol is implemented. Chapter 1 is a brief introduction to quantum computation. The physical basis of its efficiency and issues involved in its implementation are discussed. NMR quantum information processing is reviewed in more detail in Chapter 2. Chapter 3 considers some of the errors that may be introduced in the process of implementing an algorithm, and high-level ways of reducing the impact of these errors by using composite rotations. Novel general expressions for stabilising composite rotations are presented in Chapter 4 and a new class o...

  7. [Gastric magnetic resonance study (methods, semiotics)].

    Science.gov (United States)

    Stashuk, G A

    2003-01-01

    The paper shows the potentialities of gastric study by magnetic resonance imaging (MRI). The methodic aspects of gastric study have been worked out. The MRI-semiotics of the unchanged and tumor-affected wall of the stomach and techniques in examining patients with gastric cancer of various sites are described. Using the developed procedure, MRI was performed in 199 patients, including 154 patients with gastric pathology and 45 control individuals who had no altered gastric wall. Great emphasis is placed on the role of MRI in the diagnosis of endophytic (diffuse) gastric cancer that is of priority value in its morphological structure. MRI was found to play a role in the diagnosis of the spread of a tumorous process both along the walls of the stomach and to its adjacent anatomic structures.

  8. Cardiovascular magnetic resonance in carotid atherosclerotic disease

    Directory of Open Access Journals (Sweden)

    Chen Huijun

    2009-12-01

    Full Text Available Abstract Atherosclerosis is a chronic, progressive, inflammatory disease affecting many vascular beds. Disease progression leads to acute cardiovascular events such as myocardial infarction, stroke and death. The diseased carotid alone is responsible for one third of the 700,000 new or recurrent strokes occurring yearly in the United States. Imaging plays an important role in the management of atherosclerosis, and cardiovascular magnetic resonance (CMR of the carotid vessel wall is one promising modality in the evaluation of patients with carotid atherosclerotic disease. Advances in carotid vessel wall CMR allow comprehensive assessment of morphology inside the wall, contributing substantial disease-specific information beyond luminal stenosis. Although carotid vessel wall CMR has not been widely used to screen for carotid atherosclerotic disease, many trials support its potential for this indication. This review summarizes the current state of knowledge regarding carotid vessel wall CMR and its potential clinical application for management of carotid atherosclerotic disease.

  9. Automated Segmentation of Cardiac Magnetic Resonance Images

    DEFF Research Database (Denmark)

    Stegmann, Mikkel Bille; Nilsson, Jens Chr.; Grønning, Bjørn A.

    2001-01-01

    Magnetic resonance imaging (MRI) has been shown to be an accurate and precise technique to assess cardiac volumes and function in a non-invasive manner and is generally considered to be the current gold-standard for cardiac imaging [1]. Measurement of ventricular volumes, muscle mass and function...... is based on determination of the left-ventricular endocardial and epicardial borders. Since manual border detection is laborious, automated segmentation is highly desirable as a fast, objective and reproducible alternative. Automated segmentation will thus enhance comparability between and within cardiac...... studies and increase accuracy by allowing acquisition of thinner MRI-slices. This abstract demonstrates that statistical models of shape and appearance, namely the deformable models: Active Appearance Models, can successfully segment cardiac MRIs....

  10. Magnetic resonance imaging of pericardial diseases

    Energy Technology Data Exchange (ETDEWEB)

    Niwa, Koichiro; Tashima, Kazuyuki; Okajima, Yoshitomo; Nakajima, Hiromichi; Terai, Masaru; Nakajima, Hironori

    1988-10-01

    We performed magnetic resonance imaging (MRI) in 4 patients, ranged from 4 to 15 years in age, with pericardial disease (1 with pericaditis with JRA, 1 with chylopericardium, and 2 with pericarditis) for morphological and histological evaluation of the percardial disease. ECG-gated MRI was performed by the spin echo method using a superconducting MRI system operating at 0.5 tesla. In all the patients pericardial diseases were clearly demonstrated. MRI visualized the thickened pericardium as 2 to 4 mm thick curvilinear line of high signal intensity in all the patients. Pericardial effusion was detected in all the patients. Two of them showed low signal intensity and 1 showed high signal intensity. Pericardial effusion in patient with chylopericardium had markedly high signal intensity, similar to that of the subcutaneous far tissue. MRI appears to be an important modality for the evaluation of pericardial disease.

  11. Rotating-frame gradient fields for magnetic resonance imaging and nuclear magnetic resonance in low fields

    Science.gov (United States)

    Bouchard, Louis-Serge; Pines, Alexander; Demas, Vasiliki

    2014-01-21

    A system and method for Fourier encoding a nuclear magnetic resonance (NMR) signal is disclosed. A static magnetic field B.sub.0 is provided along a first direction. An NMR signal from the sample is Fourier encoded by applying a rotating-frame gradient field B.sub.G superimposed on the B.sub.0, where the B.sub.G comprises a vector component rotating in a plane perpendicular to the first direction at an angular frequency .omega.in a laboratory frame. The Fourier-encoded NMR signal is detected.

  12. Optimal sequence for magnetic resonance cholangiopancreatography

    Energy Technology Data Exchange (ETDEWEB)

    Kanzaki, Hiroshi; Akata, Soichi; Ozuki, Taizo; Abe, Kimihiko [Tokyo Medical Coll. (Japan)

    2001-09-01

    Magnetic resonance cholangiopancreatography (MRCP) has attracted attention as a useful examination for abnormalities of the pancreaticobiliary system, because it is a simple procedure. Since there are few detailed reports on optimal sequences for MRCP, we attempted to clarify the topic. The magnetic resonance imaging (MRI) equipment we used was a 1.0 Tesla super-conductive type. A fast spin echo (16 echo train) was used, and the echo space was set at 17 msec. TE was changed from 17 msec to 272 msec in 17 msec increments. TR was changed from 1,000 msec to 9,000 msec by 1,000 msec increments. Bile juice which had been collected from the PTCD tube of a patient with common bile duct cancer, was put in a test tube of 10 mm internal diameter. Saline was used as a substitute for pancreatic juice, because collection of pancreatic juice was difficult. Fat was used for contrast. Each signal intensity inside the test tube was measured and evaluated. We attempted to evaluate the signal of gastric juice by adding blueberry juice, making use of its manganese ion (Mn{sup ++}). With longer TR, the signal intensities of bile and pancreas juice increased. As TE became longer, the signal intensities of bile and pancreas juice decreased slightly, while that of fat decreased much more. In MRCP, it is necessary to set up a long TE to increase the relative signal intensity difference of fat in bile and pancreas juice. The signal intensity of gastric juice was made to disappear by the addition of blueberry juice diluted to a ratio of 1:3. (author)

  13. Categorization of aortic aneurysm thrombus morphology by magnetic resonance imaging

    DEFF Research Database (Denmark)

    de la Motte, Louise; Pedersen, Mads Møller; Thomsen, Carsten

    2013-01-01

    Magnetic resonance imaging (MRI) has been proposed for qualitative categorization of intraluminal thrombus morphology. We aimed to correlate the qualitative MRI categorization previously described to quantitative measurements of signal intensity and to compare morphological characteristics...... of intraluminal thrombus specimens to the appearance on magnetic resonance imaging....

  14. Magnetic resonance advection imaging of cerebrovascular pulse dynamics.

    Science.gov (United States)

    Voss, Henning U; Dyke, Jonathan P; Tabelow, Karsten; Schiff, Nicholas D; Ballon, Douglas J

    2017-04-01

    We analyze the pulsatile signal component of dynamic echo planar imaging data from the brain by modeling the dependence between local temporal and spatial signal variability. The resulting magnetic resonance advection imaging maps depict the location of major arteries. Color direction maps allow for visualization of the direction of blood vessels. The potential significance of magnetic resonance advection imaging maps is demonstrated on a functional magnetic resonance imaging data set of 19 healthy subjects. A comparison with the here introduced pulse coherence maps, in which the echo planar imaging signal is correlated with a cardiac pulse signal, shows that the magnetic resonance advection imaging approach results in a better spatial definition without the need for a pulse reference. In addition, it is shown that magnetic resonance advection imaging velocities can be estimates of pulse wave velocities if certain requirements are met, which are specified. Although for this application magnetic resonance advection imaging velocities are not quantitative estimates of pulse wave velocities, they clearly depict local pulsatile dynamics. Magnetic resonance advection imaging can be applied to existing dynamic echo planar imaging data sets with sufficient spatiotemporal resolution. It is discussed whether magnetic resonance advection imaging might have the potential to evolve into a biomarker for the health of the cerebrovascular system.

  15. Magnetic Resonance in Food Science - Food for Thought

    NARCIS (Netherlands)

    Duynhoven, van J.P.M.; Belton, P.S.; Webb, G.A.; As, van H.

    2013-01-01

    There are many challenges and problems in food science and magnetic resonance methods may be used to provide answers and deepen both fundamental and practical knowledge. This book presents innovations in magnetic resonance and in particular applications to understanding the functionality of foods,

  16. Resonance magnetic x-ray scattering study of erbium

    DEFF Research Database (Denmark)

    Sanyal, M.K.; Gibbs, D.; Bohr, J.

    1994-01-01

    The magnetic phases of erbium have been studied by resonance x-ray-scattering techniques. When the incident x-ray energy is tuned near the L(III) absorption edge, large resonant enhancements of the magnetic scattering are observed above 18 K. We have measured the energy and polarization dependence...

  17. Nuclear magnetic resonance force microscopy at millikelvin temperatures

    NARCIS (Netherlands)

    Haan, Arthur Mattheus Johannes den

    2016-01-01

    Nuclear magnetic resonance force microscopy (MRFM) is a technique which combines magnetic resonance imaging (MRI) with scanning probe microscopy (SPM). The final goal is to develop this technique to such a level that the atomic structure of a virus or protein can be revealed by this microscope. This

  18. Selectivity in multiple quantum nuclear magnetic resonance

    Energy Technology Data Exchange (ETDEWEB)

    Warren, Warren Sloan [Univ. of California, Berkeley, CA (United States). Dept. of Chemistry; Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Materials Sciences Division

    1980-11-01

    The observation of multiple-quantum nuclear magnetic resonance transitions in isotropic or anisotropic liquids is shown to give readily interpretable information on molecular configurations, rates of motional processes, and intramolecular interactions. However, the observed intensity of high multiple-quantum transitions falls off dramatically as the number of coupled spins increases. The theory of multiple-quantum NMR is developed through the density matrix formalism, and exact intensities are derived for several cases (isotropic first-order systems and anisotropic systems with high symmetry) to shown that this intensity decrease is expected if standard multiple-quantum pulse sequences are used. New pulse sequences are developed which excite coherences and produce population inversions only between selected states, even though other transitions are simultaneously resonant. One type of selective excitation presented only allows molecules to absorb and emit photons in groups of n. Coherent averaging theory is extended to describe these selective sequences, and to design sequences which are selective to arbitrarily high order in the Magnus expansion. This theory and computer calculations both show that extremely good selectivity and large signal enhancements are possible.

  19. Magnetic resonance spectroscopy as a diagnostic modality for carcinoma thyroid

    Energy Technology Data Exchange (ETDEWEB)

    Gupta, Nikhil [Department of Surgery, Maulana Azad Medical College, Lok Nayak Hospital, New Delhi (India)], E-mail: nikhil_ms26@yahoo.co.in; Kakar, Arun K. [Department of Surgery, Maulana Azad Medical College, Lok Nayak Hospital, New Delhi (India); Chowdhury, Veena [Department of Radiodiagnosis, Maulana Azad Medical College, Lok Nayak Hospital, New Delhi (India); Gulati, Praveen [MR Centre, A-23 Green Park, New Delhi (India); Shankar, L. Ravi [Department of Radioiodine Uptake and Imaging, Institute of Nucler Medicine and Allied Sciences (INMAS), Timarpur, New Delhi (India); Vindal, Anubhav [Department of Surgery, Maulana Azad Medical College, Lok Nayak Hospital, New Delhi (India)

    2007-12-15

    Aim: The aim of this study was to observe the findings of magnetic resonance spectroscopy of solitary thyroid nodules and its correlation with histopathology. Materials and methods: In this study, magnetic resonance spectroscopy was carried out on 26 patients having solitary thyroid nodules. Magnetic resonance spectroscopy (MRS) was performed on a 1.5 T super conductive system with gradient strength of 33 mTs. Fine needle aspiration cytology was done after MRS. All 26 patients underwent surgery either because of cytopathologically proven malignancy or because of cosmetic reasons. Findings of magnetic resonance spectroscopy were compared with histopathology of thyroid specimens. Results and conclusion: It was seen that presence or absence of choline peak correlates very well with presence or absence of malignant foci with in the nodule (sensitivity = 100%; specificity = 88.88%). These results indicate that magnetic resonance spectroscopy may prove to be an useful diagnostic modality for carcinoma thyroid.

  20. The electrically detected magnetic resonance microscope: combining conductive atomic force microscopy with electrically detected magnetic resonance.

    Science.gov (United States)

    Klein, Konrad; Hauer, Benedikt; Stoib, Benedikt; Trautwein, Markus; Matich, Sonja; Huebl, Hans; Astakhov, Oleksandr; Finger, Friedhelm; Bittl, Robert; Stutzmann, Martin; Brandt, Martin S

    2013-10-01

    We present the design and implementation of a scanning probe microscope, which combines electrically detected magnetic resonance (EDMR) and (photo-)conductive atomic force microscopy ((p)cAFM). The integration of a 3-loop 2-gap X-band microwave resonator into an AFM allows the use of conductive AFM tips as a movable contact for EDMR experiments. The optical readout of the AFM cantilever is based on an infrared laser to avoid disturbances of current measurements by absorption of straylight of the detection laser. Using amorphous silicon thin film samples with varying defect densities, the capability to detect a spatial EDMR contrast is demonstrated. Resonant current changes as low as 20 fA can be detected, allowing the method to realize a spin sensitivity of 8×10(6)spins/√Hz at room temperature.

  1. Resonant inverter supplied Interior Permanent Magnet (IPM) motor ...

    African Journals Online (AJOL)

    In this paper, rotor position in relation to the resonant frequency component current in the stator winding of DC-voltage link resonant inverter supplied Interior Permanent Magnet (IPM) motor has been developed. Six reference frames are used to relate the rotor position angle to the resonant frequency component current ...

  2. Magnetic resonance imaging of oscillating electrical currents.

    Science.gov (United States)

    Halpern-Manners, Nicholas W; Bajaj, Vikram S; Teisseyre, Thomas Z; Pines, Alexander

    2010-05-11

    Functional MRI has become an important tool of researchers and clinicians who seek to understand patterns of neuronal activation that accompany sensory and cognitive processes. However, the interpretation of fMRI images rests on assumptions about the relationship between neuronal firing and hemodynamic response that are not firmly grounded in rigorous theory or experimental evidence. Further, the blood-oxygen-level-dependent effect, which correlates an MRI observable to neuronal firing, evolves over a period that is 2 orders of magnitude longer than the underlying processes that are thought to cause it. Here, we instead demonstrate experiments to directly image oscillating currents by MRI. The approach rests on a resonant interaction between an applied rf field and an oscillating magnetic field in the sample and, as such, permits quantitative, frequency-selective measurements of current density without spatial or temporal cancellation. We apply this method in a current loop phantom, mapping its magnetic field and achieving a detection sensitivity near the threshold required for the detection of neuronal currents. Because the contrast mechanism is under spectroscopic control, we are able to demonstrate how ramped and phase-modulated spin-lock radiation can enhance the sensitivity and robustness of the experiment. We further demonstrate the combination of these methods with remote detection, a technique in which the encoding and detection of an MRI experiment are separated by sample flow or translation. We illustrate that remotely detected MRI permits the measurement of currents in small volumes of flowing water with high sensitivity and spatial resolution.

  3. Italian registry of cardiac magnetic resonance

    Energy Technology Data Exchange (ETDEWEB)

    Francone, Marco [Department of Radiological, Oncological and Pathological Sciences, Sapienza University of Rome (Italy); Di Cesare, Ernesto, E-mail: ernesto.dicesare@cc.univaq.it [Dipartimento di Scienze Cliniche Applicate e Biotecnologie, Università di L’Aquila (Italy); Cademartiri, Filippo [Cardio-Vascular Imaging Unit, Giovanni XXIII Hospital, Monastier di Treviso, TV (Italy); Erasmus Medical Center University, Rotterdam (Netherlands); Pontone, Gianluca [IRCCS Centro Cardiologico Monzino (Italy); Lovato, Luigi [Policlinico S. Orsola Bologna (Italy); Matta, Gildo [Azienda ospedaliera G Brotzu Cagliari (Italy); Secchi, Francesco [IRCCS Policlinico San Donato, Radiology Unit, Milan (Italy); Maffei, Erica [Cardio-Vascular Imaging Unit, Giovanni XXIII Hospital, Monastier di Treviso, TV (Italy); Erasmus Medical Center University, Rotterdam (Netherlands); Pradella, Silvia [Azienda Ospedaliera Universitaria Careggi (Italy); Carbone, Iacopo [Department of Radiological, Oncological and Pathological Sciences, Sapienza University of Rome (Italy); Marano, Riccardo [Policlinico Gemelli, Università Cattolica Roma (Italy); Bacigalupo, Lorenzo [Ospedale Galliera, Genova (Italy); Chiodi, Elisabetta [Ospedale S. Anna Ferrara (Italy); Donato, Rocco [Azienda Ospedaliera Universitaria G. Martino, Me (Italy); Sbarbati, Stefano [Ospedale Madre Giuseppina Vannini, Roma (Italy); De Cobelli, Francesco [IRCCS S. Raffaele, Università Vita Salute, Milano (Italy); Di Renzi, Paolo [Fate Bene Fratelli Isola tiberina, Roma (Italy); Ligabue, Guido; Mancini, Andrea [Azienda Ospedaliera-Universitaria Policlinico di Modena (Italy); Palmieri, Francesco [Diparimento di Diagnostica per immagini e radiologia interventistica, Ospedale S. Maria delle Grazie, Pozzuoli, Napoli (Italy); and others

    2014-01-15

    Objectives: Forty sites were involved in this multicenter and multivendor registry, which sought to evaluate indications, spectrum of protocols, impact on clinical decision making and safety profile of cardiac magnetic resonance (CMR). Materials and methods: Data were prospectively collected on a 6-month period and included 3376 patients (47.2 ± 19 years; range 1–92 years). Recruited centers were asked to complete a preliminary general report followed by a single form/patient. Referral physicians were not required to exhibit any specific certificate of competency in CMR imaging. Results: Exams were performed with 1.5 T scanners in 96% of cases followed by 3 T (3%) and 1 T (1%) magnets and contrast was administered in 84% of cases. The majority of cases were performed for the workup of inflammatory heart disease/cardiomyopathies representing overall 55.7% of exams followed by the assessment of myocardial viability and acute infarction (respectively 6.9% and 5.9% of patients). In 49% of cases the final diagnosis provided was considered relevant and with impact on patient's clinical/therapeutic management. Safety evaluation revealed 30 (0.88%) clinical events, most of which due to patient's preexisting conditions. Radiological reporting was recorded in 73% of exams. Conclusions: CMR is performed in a large number of centers in Italy with relevant impact on clinical decision making and high safety profile.

  4. Parametric resonance induced chaos in magnetic damped driven pendulum

    Energy Technology Data Exchange (ETDEWEB)

    Khomeriki, Giorgi, E-mail: giokhomeriki123@gmail.com

    2016-07-15

    A damped driven pendulum with a magnetic driving force, appearing from a solenoid, where ac current flows is considered. The solenoid acts on the magnet, which is located at a free end of the pendulum. In this system the existence and interrelation of chaos and parametric resonance is theoretically examined. Derived analytical results are supported by numerical simulations and conducted experiments. - Highlights: • A damped magnetic pendulum is considered driven by off resonant magnetic field. • Our system is chaotic only when the conditions for parametric resonance are fulfilled. • Conducted experiments give a good agreement with theory and numerical simulations. • Calculated Lyapunov exponents are compared with parametric instability growth rates.

  5. Clinical application of functional magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Alwatban, Adnan Z.W

    2002-07-01

    The work described in this thesis was carried out at the Magnetic Resonance Centre of the University of Nottingham during the time from May 1998 to April 2001, and is the work of the author except where indicated by reference. The main source of signal changes in functional magnetic resonance imaging (fMRJ) is the fluctuation of paramagnetic deoxyhaemoglobin in the venous blood during different states of functional performance. For the work of this thesis, fMRI studies were carried out using a 3 T MR system with an echo planar imaging (EPI) pulse sequence. Hearing research utilising fMRI has been previously reported in normal subjects. Hearing fMRI is normally performed by stimulating the auditory cortex via an acoustic task presentation such as music, tone, etc. However, performing the same research on deaf subjects requires special equipment to be designed to allow direct stimulation of the auditory nerve. In this thesis, a new method of direct electrical stimulation of the auditory nerve is described that uses a transtympanic electrode implanted onto the surface of the cochlea. This approach would however, result in electromotive forces (EMFs) being induced by the time varying magnetic field, which would lead to current flow and heating, as well as deflection of the metallic electrode within the static magnetic field, and image distortion due to the magnetic susceptibility difference. A gold-plated tungsten electrode with a zero magnetic susceptibility was developed to avoid image distortion. Used with carbon leads and a carbon reference pad, it enabled safe, distortion-free fMRI studies of deaf subjects. The study revealed activation of the primary auditory cortex. This fMRI procedure can be used to demonstrate whether the auditory pathway is fully intact, and may provide a useful method for pre-operative assessment of candidates for cochlear implantation. Glucose is the energy source on which the function of the human brain is entirely dependent. Failure to

  6. Waveguide volume probe for magnetic resonance imaging and spectroscopy

    DEFF Research Database (Denmark)

    2015-01-01

    The present disclosure relates to a probe for use within the field of nuclear magnetic resonance, such as magnetic resonance imaging (MRI), and magnetic resonance spectroscopy (MRS)). One embodiment relates to an RF probe for magnetic resonance imaging and/or spectroscopy comprising a conductive...... non-magnetic hollow waveguide having an internal volume and at least one open end, one or more capacitors and at least a first conductive non-magnetic wire, wherein said first conductive wire connects at least one of said one or more capacitors to opposite walls of one open end of the waveguide...... and wherein said first conductive wire and said one or more capacitors are located outside of said internal volume, wherein the internal volume of the hollow waveguide defines an imaging volume or sample volume....

  7. Controlling interactions between highly magnetic atoms with Feshbach resonances.

    Science.gov (United States)

    Kotochigova, Svetlana

    2014-09-01

    This paper reviews current experimental and theoretical progress in the study of dipolar quantum gases of ground and meta-stable atoms with a large magnetic moment. We emphasize the anisotropic nature of Feshbach resonances due to coupling to fast-rotating resonant molecular states in ultracold s-wave collisions between magnetic atoms in external magnetic fields. The dramatic differences in the distribution of resonances of magnetic (7)S3 chromium and magnetic lanthanide atoms with a submerged 4f shell and non-zero electron angular momentum is analyzed. We focus on dysprosium and erbium as important experimental advances have been recently made to cool and create quantum-degenerate gases for these atoms. Finally, we describe progress in locating resonances in collisions of meta-stable magnetic atoms in electronic P-states with ground-state atoms, where an interplay between collisional anisotropies and spin-orbit coupling exists.

  8. Enhancement of Faraday effect in one-dimensional magneto-optical photonic crystal including a magnetic layer with wavelength dependent off-diagonal elements of dielectric constant tensor

    Energy Technology Data Exchange (ETDEWEB)

    Inui, Chie; Ozaki, Shinsuke; Kura, Hiroaki [Graduate School of Science and Technology, Keio University, 3-14-1 Hiyoshi, Kohoku-ku, Yokohama-shi 223-8522 (Japan); Sato, Tetsuya, E-mail: satoh@appi.keio.ac.jp [Graduate School of Science and Technology, Keio University, 3-14-1 Hiyoshi, Kohoku-ku, Yokohama-shi 223-8522 (Japan)

    2011-10-15

    Optical and magneto-optical properties of one-dimensional magneto-optical photonic crystal (1-D MPC) prepared by the sol-gel dip-coating method, including a magnetic defect layer composed of mixture of CoFe{sub 2}O{sub 4} and SiO{sub 2}, are investigated from both the experimental and theoretical standpoints. The resonant transmission of light was observed around 570 nm in the photonic band gap. The Faraday rotation angle {theta}{sub F} showed two maxima at 490 and 640 nm, and the wavelength dependence of {theta}{sub F} above 760 nm was similar to that of the CoFe{sub 2}O{sub 4}+SiO{sub 2} single-layer film. The two maxima of {theta}{sub F} are attributed to the enhanced Faraday rotation of nonmagnetic TiO{sub 2} layers in the cavity structure and that in magnetic CoFe{sub 2}O{sub 4}+SiO{sub 2} layer through the light localization in MPC. The maximum value of {theta}{sub F} due to the magnetic CoFe{sub 2}O{sub 4}+SiO{sub 2} layer in the MPC was 22-times larger than that in the single-layer film. The simulation study of MPC with CoFe{sub 2}O{sub 4}+SiO{sub 2} magnetic defect layer, based on the matrix approach method, showed that the resonant light transmission was accompanied by the localization of electric field, and large enhancement of {theta}{sub F} appeared at different wavelengths so as to agree with the experimental features. This can be explained in terms of the wavelength dependent off-diagonal components of the dielectric constant tensor in addition to the large extinction coefficient in the CoFe{sub 2}O{sub 4}+SiO{sub 2} magnetic defect layer. - Highlights: > 1-D magnetic photonic crystal (MPC) prepared by sol-gel method. > Enhancement of Faraday rotation due to the magnetic defect layer of CoFe{sub 2}O{sub 4}. > Shift of wavelength of Faraday rotation maximum from resonant light transmission.

  9. Magnetic Resonance Techniques Applied to the Diagnosis and Treatment of Parkinson’s Disease

    Science.gov (United States)

    de Celis Alonso, Benito; Hidalgo-Tobón, Silvia S.; Menéndez-González, Manuel; Salas-Pacheco, José; Arias-Carrión, Oscar

    2015-01-01

    Parkinson’s disease (PD) affects at least 10 million people worldwide. It is a neurodegenerative disease, which is currently diagnosed by neurological examination. No neuroimaging investigation or blood biomarker is available to aid diagnosis and prognosis. Most effort toward diagnosis using magnetic resonance (MR) has been focused on the use of structural/anatomical neuroimaging and diffusion tensor imaging (DTI). However, deep brain stimulation, a current strategy for treating PD, is guided by MR imaging (MRI). For clinical prognosis, diagnosis, and follow-up investigations, blood oxygen level-dependent MRI, DTI, spectroscopy, and transcranial magnetic stimulation have been used. These techniques represent the state of the art in the last 5 years. Here, we focus on MR techniques for the diagnosis and treatment of Parkinson’s disease. PMID:26191037

  10. Quantifying mixing using magnetic resonance imaging.

    Science.gov (United States)

    Tozzi, Emilio J; McCarthy, Kathryn L; Bacca, Lori A; Hartt, William H; McCarthy, Michael J

    2012-01-25

    Mixing is a unit operation that combines two or more components into a homogeneous mixture. This work involves mixing two viscous liquid streams using an in-line static mixer. The mixer is a split-and-recombine design that employs shear and extensional flow to increase the interfacial contact between the components. A prototype split-and-recombine (SAR) mixer was constructed by aligning a series of thin laser-cut Poly (methyl methacrylate) (PMMA) plates held in place in a PVC pipe. Mixing in this device is illustrated in the photograph in Fig. 1. Red dye was added to a portion of the test fluid and used as the minor component being mixed into the major (undyed) component. At the inlet of the mixer, the injected layer of tracer fluid is split into two layers as it flows through the mixing section. On each subsequent mixing section, the number of horizontal layers is duplicated. Ultimately, the single stream of dye is uniformly dispersed throughout the cross section of the device. Using a non-Newtonian test fluid of 0.2% Carbopol and a doped tracer fluid of similar composition, mixing in the unit is visualized using magnetic resonance imaging (MRI). MRI is a very powerful experimental probe of molecular chemical and physical environment as well as sample structure on the length scales from microns to centimeters. This sensitivity has resulted in broad application of these techniques to characterize physical, chemical and/or biological properties of materials ranging from humans to foods to porous media (1, 2). The equipment and conditions used here are suitable for imaging liquids containing substantial amounts of NMR mobile (1)H such as ordinary water and organic liquids including oils. Traditionally MRI has utilized super conducting magnets which are not suitable for industrial environments and not portable within a laboratory (Fig. 2). Recent advances in magnet technology have permitted the construction of large volume industrially compatible magnets suitable for

  11. Linear electric field effects in magnetic anisotropy and ferromagnetic resonance

    Science.gov (United States)

    Rado, George T.

    1980-01-01

    The concept, theory and measurement of electric-field-dependent macroscopic magnetic anisotropy energies are reviewed with examples involving magnetite and lithium ferrite. Also discussed are applications to the elucidation of magnetization processes, the determination of magnetic symmetry and the shifting of a ferromagnetic resonance with an applied electric field.

  12. Accurate measurement of cortical bone elasticity tensor with resonant ultrasound spectroscopy.

    Science.gov (United States)

    Bernard, Simon; Grimal, Quentin; Laugier, Pascal

    2013-02-01

    Resonant ultrasound spectroscopy (RUS) allows to accurately characterize the complete set of elastic constants of an anisotropic material from a set of measured mechanical resonant frequencies of a specimen. This method does not suffer from the drawbacks and limitations of the conventional sound velocity approach, but has been reported to fail to measure bone because of its strong viscoelastic damping. In this study, we take advantage of recent developments of RUS to overcome this limitation. The frequency response of a human cortical bone specimen (about 5 × 7 × 7 mm(3)) was measured between 100 and 280 kHz. Despite an important overlapping of the resonant peaks 20 resonant frequencies could be retrieved by using a dedicated signal processing method. The experimental frequencies were progressively matched to the frequencies predicted by a model of the sample whose elastic constants were adjusted. The determined diagonal elastic constants were in good agreement with concurrent sound velocity measurements performed in the principal directions of the specimen. This study demonstrates that RUS is suitable for an accurate measurement of cortical bone anisotropic elasticity. In particular, precision of measured Young and shear moduli is about 0.5%. Copyright © 2012 Elsevier Ltd. All rights reserved.

  13. Improving the calculation of electron paramagnetic resonance hyperfine coupling tensors for d-block metals

    DEFF Research Database (Denmark)

    Hedegård, Erik Donovan; Kongsted, Jacob; Sauer, Stephan P. A.

    2012-01-01

    Calculation of hyperfine coupling constants (HFCs) of Electron Paramagnetic Resonance from first principles can be a beneficial compliment to experimental data in cases where the molecular structure is unknown. We have recently investigated basis set convergence of HFCs in d-block complexes...

  14. Asbestos-related pericardial thickening detected by magnetic resonance imaging.

    Science.gov (United States)

    Jarad, N A; Underwood, S R; Rudd, R M

    1993-05-01

    Magnetic resonance imaging was performed in four male asbestos workers in whom the chest radiograph revealed pleural but not pulmonary or pericardial disease. Patients underwent thoracic multislice spin echo imaging, with measurement of left and right ventricular volumes at end-diastole and end-systole, and a study of the flow in the superior vena cava as an indirect measure to the filling of the right ventricle. Patients also underwent respiratory function tests and high-resolution computed tomography (HRCT). Magnetic resonance, but not HRCT, showed pericardial thickening in two patients. Magnetic resonance demonstrated reduced diastolic flow in the superior vena cava in one patient, reflecting impaired right ventricular filling. All other magnetic resonance measurements of cardiac function were normal. HRCT demonstrated mild asbestosis in three patients in which neither the chest radiograph nor magnetic resonance showed signs of parenchymal disease, and pericardiac calcification without thickening in one patient. It is concluded that magnetic resonance is superior to HRCT in identifying pericardial thickening, but that HRCT is superior to magnetic resonance in identifying asbestos-related pleural and pulmonary disease.

  15. Magnetic resonance imaging in 122 children with spastic cerebral palsy.

    Science.gov (United States)

    Kwong, Karen L; Wong, Yiu C; Fong, Chek M; Wong, Sik N; So, Kwan T

    2004-09-01

    The interrelationship between magnetic resonance imaging findings, types of cerebral palsy, and gestation was studied. We analyzed the magnetic resonance imaging of brain in 122 children with spastic cerebral palsy. Forty-three patients had spastic hemiplegia, 61 had spastic diplegia, and 18 had spastic tetraplegia. Magnetic resonance imaging abnormalities were observed in 75% of patients. Periventricular leukomalacia accounted for 66% of abnormalities observed in patients with spastic diplegia; other types of brain lesions were uncommon. In patients with spastic tetraplegia, two types of magnetic resonance imaging abnormalities predominated: congenital brain anomalies and term-type brain injuries, 42% and 33% respectively. Types of magnetic resonance imaging abnormalities were more heterogeneous in patients with spastic hemiplegia. Preterm brain injuries (periventricular leukomalacia and posthemorrhagic porencephaly) were observed often in patients born at preterm but were also observed in patients born at term. Term-type brain injuries (term-type border-zone infarct, basal ganglia-thalamic lesion, subcortical leukomalacia, and multicystic encephalomalacia) were observed only in patients born at or near term. We conclude that magnetic resonance imaging findings for patients with spastic cerebral palsy were closely related to types of cerebral palsy and gestation at birth. Magnetic resonance imaging in patients with perinatal brain injury may reflect pathologic changes and is useful in understanding and evaluating cerebral palsy.

  16. Multimodality Imaging Approach in Alzheimer disease. Part I: Structural MRI, Functional MRI, Diffusion Tensor Imaging and Magnetization Transfer Imaging

    Directory of Open Access Journals (Sweden)

    Chetsadaporn Promteangtrong

    Full Text Available ABSTRACT The authors make a complete review of the potential clinical applications of traditional and novel magnetic resonance imaging (MRI techniques in the evaluation of patients with Alzheimer's disease, including structural MRI, functional MRI, diffusion tension imaging and magnetization transfer imaging.

  17. Science Drivers and Technical Challenges for Advanced Magnetic Resonance

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, Karl T.; Pruski, Marek; Washton, Nancy M.; Lipton, Andrew S.

    2013-03-07

    This report recaps the "Science Drivers and Technical Challenges for Advanced Magnetic Resonance" workshop, held in late 2011. This exploratory workshop's goal was to discuss and address challenges for the next generation of magnetic resonance experimentation. During the workshop, participants from throughout the world outlined the science drivers and instrumentation demands for high-field dynamic nuclear polarization (DNP) and associated magnetic resonance techniques, discussed barriers to their advancement, and deliberated the path forward for significant and impactful advances in the field.

  18. Advances in cardiac magnetic resonance imaging of congenital heart disease

    Energy Technology Data Exchange (ETDEWEB)

    Driessen, Mieke M.P. [University of Utrecht, University Medical Center Utrecht, Department of Radiology, PO Box 85500, Utrecht (Netherlands); University of Utrecht, University Medical Center Utrecht, Department of Cardiology, PO Box 85500, Utrecht (Netherlands); The Interuniversity Cardiology Institute of the Netherlands (ICIN) - Netherlands Heart Institute, PO Box 19258, Utrecht (Netherlands); Breur, Johannes M.P.J. [Wilhelmina Children' s Hospital, University Medical Center Utrecht, Department of Pediatric Cardiology, PO Box 85500, Utrecht (Netherlands); Budde, Ricardo P.J.; Oorschot, Joep W.M. van; Leiner, Tim [University of Utrecht, University Medical Center Utrecht, Department of Radiology, PO Box 85500, Utrecht (Netherlands); Kimmenade, Roland R.J. van; Sieswerda, Gertjan Tj [University of Utrecht, University Medical Center Utrecht, Department of Cardiology, PO Box 85500, Utrecht (Netherlands); Meijboom, Folkert J. [University of Utrecht, University Medical Center Utrecht, Department of Cardiology, PO Box 85500, Utrecht (Netherlands); Wilhelmina Children' s Hospital, University Medical Center Utrecht, Department of Pediatric Cardiology, PO Box 85500, Utrecht (Netherlands)

    2015-01-01

    Due to advances in cardiac surgery, survival of patients with congenital heart disease has increased considerably during the past decades. Many of these patients require repeated cardiovascular magnetic resonance imaging to assess cardiac anatomy and function. In the past decade, technological advances have enabled faster and more robust cardiovascular magnetic resonance with improved image quality and spatial as well as temporal resolution. This review aims to provide an overview of advances in cardiovascular magnetic resonance hardware and acquisition techniques relevant to both pediatric and adult patients with congenital heart disease and discusses the techniques used to assess function, anatomy, flow and tissue characterization. (orig.)

  19. Magnetic resonance imaging of primary vaginal carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, M.B. [Department of Diagnostic Radiology, Christie Hospital NHS Trust, Withington, Manchester (United Kingdom)]. E-mail: ben.taylor@christie-tr.nwest.nhs.uk; Dugar, N. [Department of Diagnostic Radiology, Christie Hospital NHS Trust, Withington, Manchester (United Kingdom); Davidson, S.E. [Radiation Oncology, Christie Hospital NHS Trust, Withington, Manchester (United Kingdom); Carrington, B.M. [Department of Diagnostic Radiology, Christie Hospital NHS Trust, Withington, Manchester (United Kingdom)

    2007-06-15

    Aims: To describe the magnetic resonance imaging (MRI) features of vaginal carcinoma and to suggest a role for MRI in its management. Materials and methods: Twenty-five patients with primary vaginal carcinoma treated at our institution between 1996 and 2005 were included in the study. The MRI examinations were reviewed and tumour dimensions, signal characteristics and involvement of pelvic structures were documented, as were sites of enlarged lymph nodes and metastases. Details of patient treatment and outcome were obtained from the clinical notes. Results: The median patient age was 54 years (range 31-86 years). Tumour maximum diameter ranged from 1.6-11.3 cm (mean 3.7 cm). Most tumours were of iso-intense signal to muscle on T1-weighted images and hyper-intense to muscle on T2-weighted images. Eighty-eight percent of patients had tumour extending beyond the vagina and 56% of patients had Figo stage III or above tumours. Sixteen patients were treated with radiotherapy (two with chemoradiotherapy), five with surgery and four with supportive care. Ten patients (40%) died of their disease during the study period. The MRI stage of the tumour correlated with survival. Conclusion: MRI identified over 95% of primary vaginal tumours in the present study, enabled radiological staging, which correlated with outcome, and provided information of use in treatment planning.

  20. Magnetic resonance imaging of the normal placenta

    Energy Technology Data Exchange (ETDEWEB)

    Blaicher, Wibke [Department of Gynecology and Obstetrics, University Hospital Vienna (Austria)]. E-mail: wibke.blaicher@meduniwien.ac.at; Brugger, Peter C. [Center of Anatomy and Cell Biology, University Hospital of Vienna (Austria); Mittermayer, Christoph [Department of Pediatrics, Division of Neonatology and Intensive Care, University Hospital of Vienna (Austria); Schwindt, Jens [Department of Pediatrics, Division of Neonatology and Intensive Care, University Hospital of Vienna (Austria); Deutinger, Josef [Department of Gynecology and Obstetrics, University Hospital Vienna (Austria); Bernaschek, Gerhard [Department of Gynecology and Obstetrics, University Hospital Vienna (Austria); Prayer, Daniela [Department of Radiology, Division of Neuroradiology, University Hospital of Vienna (Austria)

    2006-02-15

    The goal of this study was to provide a representative description of the normal placenta with contrast medium-free magnetic resonance imaging (MRI) in order to determine a standard of reference. One hundred consecutive singleton pregnancies were investigated by MRI without application of a contrast medium. The mean gestational age (GA) at the time of investigation was 29.5 weeks (range 19-40). Patients with suspected utero-placental insufficiency (UPI) or placental anomalies were excluded. Signal intensities were assessed and correlated with the respective GA. Antenatal MRI without contrast medium was able to depict placental status and morphological changes during gestation. A regular homogeneous structure was found in weeks 19-23. Subsequently, sporadic, slightly marked lobules appeared, which increased in number and markedness with ongoing gestation. Stratification of the lobules was observed after 36 weeks. The ratio of placental and amniotic fluid signal intensities decreased significantly with higher GA and with placental grading. MRI is well suited as an imaging method for the placenta. Our data may be used as a reference in the assessment of the placenta on MRI, and may have further clinical impact with respect to the determination of UPI.

  1. Magnetic Resonance Imaging Features of Neuromyelitis Optica

    Energy Technology Data Exchange (ETDEWEB)

    You, Sun Kyung; Song, Chang June; Park, Woon Ju; Lee, In Ho; Son, Eun Hee [Chungnam National University College of Medicine, Chungnam National University Hospital, Daejeon (Korea, Republic of)

    2013-03-15

    To report the magnetic resonance (MR) imaging features of the spinal cord and brain in patients of neuromyelitis optica (NMO). Between January 2001 and March 2010, the MR images (spinal cord, brain, and orbit) and the clinical and serologic findings of 11 NMO patients were retrospectively reviewed. The contrast-enhancement of the spinal cord was performed (20/23). The presence and pattern of the contrast-enhancement in the spinal cord were classified into 5 types. Acute myelitis was monophasic in 8 patients (8/11, 72.7%); and optic neuritis preceded acute myelitis in most patients. Longitudinally extensive cord lesion (average, 7.3 vertebral segments) was involved. The most common type was the diffuse and subtle enhancement of the spinal cord with a multifocal nodular, linear or segmental intense enhancement (45%). Most of the brain lesions (5/11, 10 lesions) were located in the brain stem, thalamus and callososeptal interphase. Anti-Ro autoantibody was positive in 2 patients, and they showed a high relapse rate of acute myelitis. Anti-NMO IgG was positive in 4 patients (4/7, 66.7%). The imaging findings of acute myelitis in NMO may helpful in making an early diagnosis of NMO which can result in a severe damage to the spinal cord, and to make a differential diagnosis of multiple sclerosis and inflammatory diseases of the spinal cord such as toxocariasis.

  2. Magnetic Resonance Imaging at Ultrahigh Fields

    Science.gov (United States)

    Uğurbil, Kamil

    2014-01-01

    Since the introduction of 4 T human systems in three academic laboratories circa 1990, rapid progress in imaging and spectroscopy studies in humans at 4 T and animal model systems at 9.4 T have led to the introduction of 7 T and higher magnetic fields for human investigation at about the turn of the century. Work conducted on these platforms has demonstrated the existence of significant advantages in SNR and biological information content at these ultrahigh fields, as well as the presence of numerous challenges. Primary difference from lower fields is the deviation from the near field regime; at the frequencies corresponding to hydrogen resonance conditions at ultrahigh fields, the RF is characterized by attenuated traveling waves in the human body, which leads to image nonuniformities for a given sample-coil configuration because of interferences. These nonuniformities were considered detrimental to the progress of imaging at high field strengths. However, they are advantageous for parallel imaging for signal reception and parallel transmission, two critical technologies that account, to a large extend, for the success of ultrahigh fields. With these technologies, and improvements in instrumentation and imaging methods, ultra-high fields have provided unprecedented gains in imaging of brain function and anatomy, and started to make inroads into investigation of the human torso and extremities. As extensive as they are, these gains still constitute a prelude to what is to come given the increasingly larger effort committed to ultrahigh field research and development of ever better instrumentation and techniques. PMID:24686229

  3. Magnetic resonance imaging of navicular bursa adhesions.

    Science.gov (United States)

    Holowinski, Maureen E; Solano, Mauricio; Maranda, Louise; García-López, José M

    2012-01-01

    Adhesions occur in the navicular bursa between the deep digital flexor tendon (DDFT) and other structures. Our objectives were to describe the appearance of navicular bursa adhesions on high-field magnetic resonance (MR) images, to compare these findings to findings at navicular bursoscopy, and to determine the prevalence of lesions in the remainder of the podotrochlear apparatus. Sixteen forelimbs from 14 horses that underwent MR imaging and navicular bursoscopy were evaluated. Adhesions were considered type 1 when characterized by a discontinuity in the navicular bursa fluid signal between two structures, type 2 when the navicular bursa fluid signal was disrupted and ill-defined tissue was present between two structures, and type 3 when the fluid signal was disrupted and well-defined tissue was present between two structures. Twenty-six adhesions were suspected on MR images and nineteen were visualized at surgery. The positive predictive value was 50% for type 1 adhesions, 67% for type 2 adhesions, and 100% for type 3 adhesions. Additional lesions were detected in the navicular bursa in 15 limbs, the DDFT in 13, the navicular bone in 15, the collateral sesamoidean ligaments in 9, and the distal sesamoidean impar ligament in 8. A discontinuity in the navicular bursa fluid signal with well-defined tissue between two structures detected on high-field MR images is diagnostic for a navicular bursa adhesion. Additional lesions in the podotrochlear apparatus are common in horses with navicular bursa adhesions. © 2012 Veterinary Radiology & Ultrasound.

  4. Magnetic resonance imaging in diffuse brain injury

    Energy Technology Data Exchange (ETDEWEB)

    Yokota, Hiroyuki; Yasuda, Kazuhiro; Mashiko, Kunihiro; Henmi, Hiroshi; Otsuka, Toshibumi; Kobayashi, Shiro; Nakazawa, Shozo (Nippon Medical School, Tokyo (Japan))

    1992-01-01

    Forty cases diagnosed as diffuse brain injury (DBI) were studied by magnetic resonance imaging (MRI) performed within 3 days after injury. These cases were divided into two groups, which were the concussion group and diffuse axonal injury (DAI) group established by Gennarelli. There were no findings on computerized tomography (CT) in the concussion group except for two cases which had a brain edema or subarachnoid hemorrhage. But on MRI, high intensity areas on T2 weighted imaging were demonstrated in the cerebral white matter in this group. Many lesions in this group were thought to be edemas of the cerebral white matter, because of the fact that on serial MRI, they were isointense. In mild types of DAI, the lesions on MRI were located only in the cerebral white matter, whereas, in the severe types of DAI, lesions were located in the basal ganglia, the corpus callosum, the dorsal part of the brain stem as well as in the cerebral white matter. As for CT findings, parenchymal lesions were not visualized especially in mild DAI. Our results suggested that the lesions in cerebral concussion were edemas in cerebral white matter. In mild DAI they were non-hemorrhagic contusion; and in severe DAI they were hemorrhagic contusions in the cerebral white matter, the basal ganglia, the corpus callosum or the dorsal part of the brain stem. (author).

  5. Magnetic resonance imaging of intracavernous pathology

    Energy Technology Data Exchange (ETDEWEB)

    Komiyama, Masaki; Yasui, Toshihiro; Yagura, Hisatsugu; Fu, Yoshihiko; Baba, Mitsuru (Baba Memorial Hospital, Sakai, Osaka (Japan)); Hakuba, Akira; Nishimura, Shuro

    1989-07-01

    To evaluate the usefulness of magnetic resonance (MR) imaging of intracavernous pathology, T{sub 1}-weighted spin echo images of four vascular lesions and 10 neoplastic lesions with surgically confirmed cavernous sinus (CS) invasion were reviewed retrospectively. In one case of traumatic carotid-cavernous fistula (CCF) and one of dural arteriovenous malformation (AVM), the internal carotid artery (ICA) and rapid shunted flow were depicted as signal voids, and the relationship between the ICA and shunted flow was clearly shown. Normal venous flow appeared as a low-intensity area and was observed even in the presence of the CCF and dural AVM. In two cases of thrombosed aneurysms, the thrombosis was clearly demonstrated, along with patent arterial flow in one case; in the other case, however, it was impossible to differentiate patent arterial flow from calcification. The intensity of all neoplastic lesions was similar to that of the cerebral cortex. The relationship between the ICA and the tumors was clearly demonstrated. The visual pathways were also plainly shown unless they were involved, or markedly compressed, by tumor. CS invasion was strongly associated with four findings: (1) encasement of the ICA by the tumor; (2) marked displacement of the ICA; (3) absence of low intensity, which reflects normal venous flow, in the CS; and (4) extension of extrasellar tumors to the medial wall or of intrasellar tumors to the lateral wall. MR imaging was judged promising in the evaluation of intracavernous pathology. (author).

  6. Magnetic resonance imaging for characterizing myocardial diseases.

    Science.gov (United States)

    Saeed, Maythem; Liu, Hui; Liang, Chang-Hong; Wilson, Mark W

    2017-09-01

    The National Institute of Health defined cardiomyopathy as diseases of the heart muscle. These myocardial diseases have different etiology, structure and treatment. This review highlights the key imaging features of different myocardial diseases. It provides information on myocardial structure/orientation, perfusion, function and viability in diseases related to cardiomyopathy. The standard cardiac magnetic resonance imaging (MRI) sequences can reveal insight on left ventricular (LV) mass, volumes and regional contractile function in all types of cardiomyopathy diseases. Contrast enhanced MRI sequences allow visualization of different infarct patterns and sizes. Enhancement of myocardial inflammation and infarct (location, transmurality and pattern) on contrast enhanced MRI have been used to highlight the key differences in myocardial diseases, predict recovery of function and healing. The common feature in many forms of cardiomyopathy is the presence of diffuse-fibrosis. Currently, imaging sequences generating the most interest in cardiomyopathy include myocardial strain analysis, tissue mapping (T1, T2, T2*) and extracellular volume (ECV) estimation techniques. MRI sequences have the potential to decode the etiology by showing various patterns of infarct and diffuse fibrosis in myocarditis, amyloidosis, sarcoidosis, hypertrophic cardiomyopathy due to aortic stenosis, restrictive cardiomyopathy, arrythmogenic right ventricular dysplasia and hypertension. Integrated PET/MRI system may add in the future more information for the diagnosis and progression of cardiomyopathy diseases. With the promise of high spatial/temporal resolution and 3D coverage, MRI will be an indispensible tool in diagnosis and monitoring the benefits of new therapies designed to treat myocardial diseases.

  7. Statistical normalization techniques for magnetic resonance imaging

    Directory of Open Access Journals (Sweden)

    Russell T. Shinohara

    2014-01-01

    Full Text Available While computed tomography and other imaging techniques are measured in absolute units with physical meaning, magnetic resonance images are expressed in arbitrary units that are difficult to interpret and differ between study visits and subjects. Much work in the image processing literature on intensity normalization has focused on histogram matching and other histogram mapping techniques, with little emphasis on normalizing images to have biologically interpretable units. Furthermore, there are no formalized principles or goals for the crucial comparability of image intensities within and across subjects. To address this, we propose a set of criteria necessary for the normalization of images. We further propose simple and robust biologically motivated normalization techniques for multisequence brain imaging that have the same interpretation across acquisitions and satisfy the proposed criteria. We compare the performance of different normalization methods in thousands of images of patients with Alzheimer's disease, hundreds of patients with multiple sclerosis, and hundreds of healthy subjects obtained in several different studies at dozens of imaging centers.

  8. Nuclear magnetic resonance imaging of the kidney

    Energy Technology Data Exchange (ETDEWEB)

    Hricak, H.; Crooks, L.; Sheldon, P.; Kaufman, L.

    1983-02-01

    The role of nuclear magnetic resonance (NMR) imaging of the kidney was analyzed in 18 persons (6 normal volunteers, 3 patients with pelvocaliectasis, 2 with peripelvic cysts, 1 with renal sinus lipomatosis, 3 with renal failure, 1 with glycogen storage disease, and 2 with polycystic kidney disease). Ultrasound and/or computed tomography (CT) studies were available for comparison in every case. In the normal kidney distinct anatomical structures were clearly differentiated by NMR. The best anatomical detail ws obtained with spin echo (SE) imaging, using a pulse sequence interval of 1,000 msec and an echo delay time of 28 msec. However, in the evaluation of normal and pathological conditions, all four intensity images (SE 500/28, SE 500/56, SE 1,000/28, and SE 1,000/56) have to be analyzed. No definite advantage was found in using SE imaging with a pulse sequence interval of 1,500 msec. Inversion recovery imaging enhanced the differences between the cortex and medulla, but it had a low signal-to-noise level and, therefore, a suboptimal overall resolution. The advantages of NMR compared with CT and ultrasound are discussed, and it is concluded that NMR imaging will prove to be a useful modality in the evaluation of renal disease.

  9. Monitoring angiogenesis using magnetic resonance methods

    DEFF Research Database (Denmark)

    Holm, David Alberg

    2008-01-01

    When a tumor reaches a certain size it can no longer rely on passive perfusion for nutrition. The tumor therefore emits signaling molecules which stimulating surrounding vessels to divide and grow towards the tumor, a process known as angiogenesis. Very little angiogenesis is present in healthy a...... in a transgenic mouse model. The last manuscript presents a new method for in vivo cell labeling. This method could find use in studying the metastatic spread of cancer cells throughout the body.......-angiogenic treatment is presented in the first manuscript. In the second and third manuscript, two separate methods of quantifying perfusion, blood volume and vessel permeability are presented. The methods are used to show that drug delivery to a xenografted tumor is plausible and to show possible vascular maturation...... and the involved signaling molecules. Subsequently, a short review of contrast agents and perfusion measurements is given. Finally, methods for monitoring angiogenesis using magnetic resonance imaging are reviewed. A method for monitoring early stages of angiogenesis as well as the effect of anti...

  10. Magnetic resonance tomography of the knee joint

    Energy Technology Data Exchange (ETDEWEB)

    Puig, Stefan; Kuruvilla, Yojena Chittazhathu Kurian; Ebner, Lukas [University Hospital, University of Berne, Department of Interventional, Pediatric and Diagnostic Radiology Inselspital, Berne (Switzerland); Endel, Gottfried [Main Association of Austrian Social Insurance Institutions, Vienna (Austria)

    2015-10-15

    To compare the diagnostic performance of magnetic resonance imaging (MRI) in terms of sensitivity and specificity using a field strength of <1.0 T (T) versus ≥1.5 T for diagnosing or ruling out knee injuries or knee pathologies. The systematic literature research revealed more than 10,000 references, of which 1598 abstracts were reviewed and 87 full-text articles were retrieved. The further selection process resulted in the inclusion of four systematic reviews and six primary studies. No differences could be identified in the diagnostic performance of low- versus high-field MRI for the detection or exclusion of meniscal or cruciate ligament tears. Regarding the detection or grading of cartilage defects and osteoarthritis of the knee, the existing evidence suggests that high-field MRI is tolerably specific but not very sensitive, while there is literally no evidence for low-field MRI because only a few studies with small sample sizes and equivocal findings have been performed. We can recommend the use of low-field strength MRI systems in suspected meniscal or cruciate ligament injuries. This does, however, not apply to the diagnosis and grading of knee cartilage defects and osteoarthritis because of insufficient evidence. (orig.)

  11. Magnetic resonance tomography in confirmed multiple sclerosis

    Energy Technology Data Exchange (ETDEWEB)

    Uhlenbrock, D.; Dickmann, E.; Beyer, H.K.; Gehlen, W.

    1985-03-01

    The authors report on 21 cases of confirmed multiple sclerosis examined by both CT and magnetic resonance tomography. To safeguard the results, strict criteria were applied in accordance with the suggestions made by neurological work teams. Pathological lesions were seen in 20 patients; the MR image did not reveal anything abnormal in one case. On the average, 10.3 lesions were seen in the MR tomogram, whereas CT images showed on the average only 2.1 foci. The size and number of lesions in the MR tomogram were independent of the duration of the disease, the presented clinical symptoms, or the type of treatment at the time of examination. Evidently the sensitivity of MR tomography is very high in MS patients, but it has not yet been clarified to what extent this applies also to the specificity. Further research is mandatory. First experiences made by us show that lesions of a similar kind can also occur in diseases such as malignant lymphoma involving the brain, in vitamin B 12 deficiency syndrome, or encephalitis, and can become manifest in the MR tomogram.

  12. Cardiovascular magnetic resonance in wet beriberi

    Directory of Open Access Journals (Sweden)

    Giri Shivraman

    2011-08-01

    Full Text Available Abstract The clinical presentation of beriberi can be quite varied. In the extreme form, profound cardiovascular involvement leads to circulatory collapse and death. This case report is of a 72 year-old male who was admitted to the Neurology inpatient ward with progressive bilateral lower extremity weakness and parasthesia. He subsequently developed pulmonary edema and high output cardiac failure requiring intubation and blood pressure support. With the constellation of peripheral neuropathy, encephalopathy, ophthalmoplegia, unexplained heart failure, and lactic acidosis, thiamine deficiency was suspected. He was empirically initiated on thiamine replacement therapy and his thiamine level pre-therapy was found to be 23 nmol/L (Normal: 80-150 nmol/L, consistent with the diagnosis of beriberi. Cardiovascular magnetic resonance (CMR showed severe left ventricular systolic dysfunction, markedly increased myocardial T2, and minimal late gadolinium enhancement (LGE. After 5 days of daily 100 mg IV thiamine and supportive care, the hypotension resolved and the patient was extubated and was released from the hospital 3 weeks later. Our case shows via CMR profound myocardial edema associated with wet beriberi.

  13. Magnetic resonance imaging in retropharyngeal tendinitis

    Energy Technology Data Exchange (ETDEWEB)

    Ekbon, K.; Annell, K.; Traeff, J.; Torhall, J. (Soeder Hospital, Stockholm (Sweden))

    1994-08-01

    Seven consecutive patients with acute retropharyngeal tendinitis underwent plain X-ray and magnetic resonance imaging (MRI) of the cervical spine. All seven had marked soft tissue swelling anterior to C1 and C2 on plain X-ray, and soft tissue calcification at this level was present in five of them. On MRI, there was markedly increased signal intensity on T[sub 2]-weighted images in the acute phase and intermediate signal intensity on T[sub 1]-weighted images, anterior to the level of CI and C2, often extending as far down as C6. These changes correlated well with the soft tissue swelling seen on conventional X-ray of the cervical spine. The maximum mid-sagittal thickness of the soft issues was significantly greater in the tendinitis patients than in 12 control subjects free of symptoms from the pharynx or the cervical spine. Treatment with non-steroidal anti-inflammatory drugs rapidly alleviated symptoms, and at follow-up MRI showed regression or complete restitution of the changes. In conclusion, MRI can visualize the edematous changes in the longus colli muscle and adds useful diagnostic information in suspected cases of acute retropharyngeal tendinitis. 9 refs., 4 figs., 3 tabs.

  14. Quantum information processing and nuclear magnetic resonance

    Energy Technology Data Exchange (ETDEWEB)

    Cummins, H.K

    2001-07-01

    Quantum computers are information processing devices which operate by and exploit the laws of quantum mechanics, potentially allowing them to solve problems which are intractable using classical computers. This dissertation considers the practical issues involved in one of the more successful implementations to date, nuclear magnetic resonance (NMR). Techniques for dealing with systematic errors are presented, and a quantum protocol is implemented. Chapter 1 is a brief introduction to quantum computation. The physical basis of its efficiency and issues involved in its implementation are discussed. NMR quantum information processing is reviewed in more detail in Chapter 2. Chapter 3 considers some of the errors that may be introduced in the process of implementing an algorithm, and high-level ways of reducing the impact of these errors by using composite rotations. Novel general expressions for stabilising composite rotations are presented in Chapter 4 and a new class of composite rotations, tailored composite rotations, presented in Chapter 5. Chapter 6 describes some of the advantages and pitfalls of combining composite rotations. Experimental evaluations of the composite rotations are given in each case. An actual implementation of a quantum information protocol, approximate quantum cloning, is presented in Chapter 7. The dissertation ends with appendices which contain expansions of some equations and detailed calculations of certain composite rotation results, as well as spectrometer pulse sequence programs. (author)

  15. Magnetic resonance imaging of suspected atrial tumors.

    Science.gov (United States)

    Menegus, M A; Greenberg, M A; Spindola-Franco, H; Fayemi, A

    1992-05-01

    Two-dimensional echocardiography has become the standard technique for evaluation of cardiac and paracardiac mass lesions. We have used magnetic resonance imaging (MRI) as an independent assessment of cardiac-associated masses in patients with echocardiograms demonstrating sessile atrial tumors. MRI was performed in seven patients, ages 33 to 84, whose echocardiographic diagnoses included left atrial mass (five), right atrial mass (one), and interatrial mass (one). In four of the patients with a diagnosis of left atrial mass, MRI showed extracardiac compression of the atrium, simulating a tumor (hiatal hernia, tortuous descending aorta, bronchogenic cyst). MRI was entirely normal in one patient with an apparent left atrial mass. MRI elucidated extension of an extracavitary mass into the interatrial septum in two patients. One of these patients with an echocardiographic right atrial mass had extension of a lipoma into the interatrial septum without atrial tumor. MRI confirmed the echocardiographic diagnosis of an interatrial mass in the other patient. We conclude that MRI, because of its ability to define anatomic relationships and tissue characteristics, is a powerful noninvasive tool for evaluating suspected cardiac mass lesions. Although echocardiography remains the primary screening test for the detection of cardiac masses, MRI is a more specific modality for precise diagnosis. Correct MRI interpretation may obviate the need for invasive studies or surgery.

  16. Magnetic Resonance Imaging of Cartilage Repair

    Science.gov (United States)

    Trattnig, Siegfried; Winalski, Carl S.; Marlovits, Stephan; Jurvelin, Jukka S.; Welsch, Goetz H.; Potter, Hollis G.

    2011-01-01

    Articular cartilage lesions are a common pathology of the knee joint, and many patients may benefit from cartilage repair surgeries that offer the chance to avoid the development of osteoarthritis or delay its progression. Cartilage repair surgery, no matter the technique, requires a noninvasive, standardized, and high-quality longitudinal method to assess the structure of the repair tissue. This goal is best fulfilled by magnetic resonance imaging (MRI). The present article provides an overview of the current state of the art of MRI of cartilage repair. In the first 2 sections, preclinical and clinical MRI of cartilage repair tissue are described with a focus on morphological depiction of cartilage and the use of functional (biochemical) MR methodologies for the visualization of the ultrastructure of cartilage repair. In the third section, a short overview is provided on the regulatory issues of the United States Food and Drug Administration (FDA) and the European Medicines Agency (EMEA) regarding MR follow-up studies of patients after cartilage repair surgeries. PMID:26069565

  17. Bolus characteristics based on Magnetic Resonance Angiography

    Directory of Open Access Journals (Sweden)

    Bi Xiaoming

    2006-10-01

    Full Text Available Abstract Background A detailed contrast bolus propagation model is essential for optimizing bolus-chasing Computed Tomography Angiography (CTA. Bolus characteristics were studied using bolus-timing datasets from Magnetic Resonance Angiography (MRA for adaptive controller design and validation. Methods MRA bolus-timing datasets of the aorta in thirty patients were analyzed by a program developed with MATLAB. Bolus characteristics, such as peak position, dispersion and bolus velocity, were studied. The bolus profile was fit to a convolution function, which would serve as a mathematical model of bolus propagation in future controller design. Results The maximum speed of the bolus in the aorta ranged from 5–13 cm/s and the dwell time ranged from 7–13 seconds. Bolus characteristics were well described by the proposed propagation model, which included the exact functional relationships between the parameters and aortic location. Conclusion The convolution function describes bolus dynamics reasonably well and could be used to implement the adaptive controller design.

  18. Cardiovascular magnetic resonance in pericardial diseases

    Directory of Open Access Journals (Sweden)

    Francone Marco

    2009-05-01

    Full Text Available Abstract The pericardium and pericardial diseases in particular have received, in contrast to other topics in the field of cardiology, relatively limited interest. Today, despite improved knowledge of pathophysiology of pericardial diseases and the availability of a wide spectrum of diagnostic tools, the diagnostic challenge remains. Not only the clinical presentation may be atypical, mimicking other cardiac, pulmonary or pleural diseases; in developed countries a shift for instance in the epidemiology of constrictive pericarditis has been noted. Accurate decision making is crucial taking into account the significant morbidity and mortality caused by complicated pericardial diseases, and the potential benefit of therapeutic interventions. Imaging herein has an important role, and cardiovascular magnetic resonance (CMR is definitely one of the most versatile modalities to study the pericardium. It fuses excellent anatomic detail and tissue characterization with accurate evaluation of cardiac function and assessment of the haemodynamic consequences of pericardial constraint on cardiac filling. This review focuses on the current state of knowledge how CMR can be used to study the most common pericardial diseases.

  19. Your Radiologist Explains Magnetic Resonance Angiography (MRA)

    Medline Plus

    Full Text Available ... is a noninvasive test that uses a powerful magnetic field and a computer to produce detailed pictures of ... your body as these can interfere with the magnetic field of the MRI unit. The magnetic field is ...

  20. Tensor Rank

    OpenAIRE

    Erdtman, Elias; Jönsson, Carl

    2012-01-01

    This master's thesis addresses numerical methods of computing the typical ranks of tensors over the real numbers and explores some properties of tensors over finite fields. We present three numerical methods to compute typical tensor rank. Two of these have already been published and can be used to calculate the lowest typical ranks of tensors and an approximate percentage of how many tensors have the lowest typical ranks (for some tensor formats), respectively. The third method was developed...

  1. Preoperative functional magnetic resonance imaging (fMRI) and transcranial magnetic stimulation (TMS)

    DEFF Research Database (Denmark)

    Hartwigsen, G.; Siebner, Hartwig R.; Stippich, C.

    2010-01-01

    of essential cortex, it cannot provide information preoperatively for surgical planning.Brain imaging techniques such as functional magnetic resonance imaging (fMRI), magnetoencephalography (MEG) and transcranial magnetic stimulation (TMS) are increasingly being used to localize functionally critical cortical...

  2. Focus on advanced magnetic resonance techniques in clinical practice: magnetic resonance neurography.

    Science.gov (United States)

    Carpenter, Elizabeth L; Bencardino, Jenny T

    2015-05-01

    Magnetic resonance neurography (MRN) provides the greatest degree of soft tissue contrast in the evaluation of peripheral nerves. Utilization of MRN relies on (1) peripheral nerve anatomy, (2) the spectrum of pathology, and (3) familiarity with dedicated MR imaging techniques. Although there remain several pitfalls in MRN imaging, awareness of these pitfalls improves imaging quality and limits misinterpretation. Most importantly, maintaining a direct line of communication with the referring clinician allows for the greatest degree of diagnostic accuracy. Copyright © 2015 Elsevier Inc. All rights reserved.

  3. Radiofrequency coils for magnetic resonance applications: theory, design, and evaluation.

    Science.gov (United States)

    Giovannetti, Giulio; Hartwig, Valentina; Positano, Vincenzo; Vanello, Nicola

    2014-01-01

    Magnetic resonance imaging and magnetic resonance spectroscopy are noninvasive diagnostic techniques based on the phenomenon of nuclear magnetic resonance. Radiofrequency coils are key components in both the transmission and receiving phases of magnetic resonance systems. Transmitter coils have to produce a highly homogeneous alternating field in a wide field of view, whereas receiver coils have to maximize signal detection while minimizing noise. Development of modern magnetic resonance coils often is based on numerical methods for simulating and predicting coil performance. Numerical methods allows the behavior of the coil in the presence of realistic loads to be simulated and the coil's efficiency at high magnetic fields to be investigated. After being built, coils have to be characterized in the laboratory to optimize their setting and performance by extracting several quality indices. Successively, coils performance has to be evaluated in a scanner using standardized image quality parameters with phantom and human experiments. This article reviews the principles of radiofrequency coils, coil performance parameters, and their estimation methods using simulations, workbench, and magnetic resonance experiments. Finally, an overview of future developments in radiofrequency coils technology is included.

  4. Bose Operator Expansions of Tensor Operators in the Theory of Magnetism

    DEFF Research Database (Denmark)

    Kowalska, A.; Lindgård, Per-Anker

    1977-01-01

    A new Bose operator expansion is discussed for tensor operators in the spin systems with isotropic exchange interaction plus anisotropy. Spin wave theory for a system with planar anisotropy shows that the Goldstone theorem is fulfilled. The new expansion replaces the off diagonal single ion...

  5. Magnetomechanical coupling and ferromagnetic resonance in magnetic nanoparticles

    Science.gov (United States)

    Keshtgar, Hedyeh; Streib, Simon; Kamra, Akashdeep; Blanter, Yaroslav M.; Bauer, Gerrit E. W.

    2017-04-01

    We address the theory of the coupled lattice and magnetization dynamics of freely suspended single-domain nanoparticles. Magnetic anisotropy generates low-frequency satellite peaks in the microwave absorption spectrum and a blueshift of the ferromagnetic resonance (FMR) frequency. The low-frequency resonances are very sharp with maxima exceeding that of the FMR, because their magnetic and mechanical precessions are locked, thereby suppressing the effective Gilbert damping. Magnetic nanoparticles can operate as nearly ideal motors that convert electromagnetic into mechanical energy. The Barnett damping term is essential for obtaining physically meaningful results.

  6. Hemispheric asymmetries in dorsal language pathway white-matter tracts: A magnetic resonance imaging tractography and functional magnetic resonance imaging study.

    Science.gov (United States)

    Silva, Guilherme; Citterio, Alberto

    2017-10-01

    Introduction Previous studies have shown that the arcuate fasciculus has a leftward asymmetry in right-handers that could be correlated with the language lateralisation defined by functional magnetic resonance imaging. Nonetheless, information about the asymmetry of the other fibres that constitute the dorsal language pathway is scarce. Objectives This study investigated the asymmetry of the white-matter tracts involved in the dorsal language pathway through the diffusion tensor imaging (DTI) technique, in relation to language hemispheric dominance determined by task-dependent functional magnetic resonance imaging (fMRI). Methods We selected 11 patients (10 right-handed) who had been studied with task-dependent fMRI for language areas and DTI and who had no language impairment or structural abnormalities that could compromise magnetic resonance tractography of the fibres involved in the dorsal language pathway. Laterality indices (LI) for fMRI and for the volumes of each tract were calculated. Results In fMRI, all the right-handers had left hemispheric lateralisation, and the ambidextrous subject presented right hemispheric dominance. The arcuate fasciculus LI was strongly correlated with fMRI LI ( r = 0.739, p = 0.009), presenting the same lateralisation of fMRI in seven subjects (including the right hemispheric dominant). It was not asymmetric in three cases and had opposite lateralisation in one case. The other tracts presented predominance for rightward lateralisation, especially superior longitudinal fasciculus (SLF) II/III (nine subjects), but their LI did not correlate (directly or inversely) with fMRI LI. Conclusion The fibres that constitute the dorsal language pathway have an asymmetric distribution in the cerebral hemispheres. Only the asymmetry of the arcuate fasciculus is correlated with fMRI language lateralisation.

  7. Serial magnetic resonance imaging of central pontine myelinolysis

    NARCIS (Netherlands)

    Buis, CI; Wijdicks, EFM

    Central Pontine Myelinolysis (CPM) is a rare neurologic complication after liver transplantation. The true incidence of CPM after orthotopic liver tranplantation remains an estimate. However, with the introduction of magnetic resonance imaging, early recognition became feasible. In this report, we

  8. Diffusion-weighted magnetic resonance imaging in ileocolonic Crohn's disease

    DEFF Research Database (Denmark)

    Juel, Mie A; Rafaelsen, Søren Rafael; Nathan, Torben

    Background: Diffusion-weighted magnetic resonance imaging (dw- MRI) utilizes differences in the motion of water molecules between tissues for image formation without administration of contrast materials. Inflammation in the bowel wall slows water transit resulting in lower apparent diffusions...

  9. Enhancing contrast of magnetic resonance imaging in patients with ...

    African Journals Online (AJOL)

    DTPA), a recent magnetic resonance imaging (MRI) contrast agent, in hepatobiliary system of patients with liver cirrhosis. Methods: Liver cirrhosis patients that underwent contrast MRI examination at Renai Hospital, Taipei City, Taiwan were ...

  10. Magnetic resonance imaging of head and neck vascular anomalies ...

    African Journals Online (AJOL)

    Magnetic resonance imaging of head and neck vascular anomalies: pearls and pitfalls. Shaimaa Abdelsattar Mohammad, Amr Abdelhamid Abou Zeid, Ahmed M. Fawzi, Mohamed M. Dahab, Iman A. Ragab, Osama El-Naggar ...

  11. Normal perinatal and paediatric postmortem magnetic resonance imaging appearances

    Energy Technology Data Exchange (ETDEWEB)

    Arthurs, Owen J. [Department of Radiology, Great Ormond Street Hospital for Children NHS Foundation Trust, London (United Kingdom); UCL Institute of Child Health, London (United Kingdom); Barber, Joy L. [Department of Radiology, Great Ormond Street Hospital for Children NHS Foundation Trust, London (United Kingdom); Taylor, Andrew M. [Cardiorespiratory Division, Great Ormond Street Hospital for Children NHS Foundation Trust, London (United Kingdom); UCL Institute of Cardiovascular Science, Centre for Cardiovascular Imaging, London (United Kingdom); Sebire, Neil J. [UCL Institute of Child Health, London (United Kingdom); Department of Histopathology, Great Ormond Street Hospital for Children NHS Foundation Trust, London (United Kingdom)

    2015-04-01

    As postmortem imaging becomes more widely used following perinatal and paediatric deaths, the correct interpretation of images becomes imperative, particularly given the increased use of postmortem magnetic resonance imaging. Many pathological processes may have similar appearances in life and following death. A thorough knowledge of normal postmortem changes is therefore required within postmortem magnetic resonance imaging to ensure that these are not mistakenly interpreted as significant pathology. Similarly, some changes that are interpreted as pathological if they occur during life may be artefacts on postmortem magnetic resonance imaging that are of limited significance. This review serves to illustrate briefly those postmortem magnetic resonance imaging changes as part of the normal changes after death in fetuses and children, and highlight imaging findings that may confuse or mislead an observer to identifying pathology where none is present. (orig.)

  12. Magnetic resonance tomography for trauma of the cervical spine

    Energy Technology Data Exchange (ETDEWEB)

    Meydam, K.; Sehlen, S.; Schlenkhoff, D.; Kiricuta, J.C.; Beyer, H.K.

    1986-12-01

    Twenty patients who had suffered spinal trauma were examined by magnetic resonance tomography. Fifteen patients with first degree trauma in Erdmann's classification showed no abnormality. Magnetic resonance tomography of the cervical spine appears to be a suitable method for investigating patients with whiplash injuries. It is indicated following severe flexion injuries with subluxations and neurological symptoms, since it is the only method that can demonstrate the spinal cord directly and completely and show the extent of cord compression. For patients with thoracic trauma and rapidly developing neurological symptoms, magnetic resonance tomography is ideal for showing post-traumatic syringomyelia. Magnetic resonance tomography following whiplash injuries is recommended if plain films of the cervical spine show any abnormalities, as well as for the investigation of acute or sub-acute neurological abnormalities. The various findings are discussed.

  13. Cellular solid-state Nuclear Magnetic Resonance spectroscopy

    NARCIS (Netherlands)

    Renault, M.A.M.; Tommassen-van Boxtel, H.A.M.; Bos, M.P.; Post, J.A.; Tommassen, J.P.M.; Baldus, M.

    2012-01-01

    Decrypting the structure, function, and molecular interactions of complex molecular machines in their cellular context and at atomic resolution is of prime importance for understanding fundamental physiological processes. Nuclear magnetic resonance is a wellestablished imaging method that can

  14. Nuclear magnetic resonance data of C4H8S

    Science.gov (United States)

    Mikhova, B. M.

    This document is part of Part 6 `Organic Metalloid Compounds' of Subvolume D 'Chemical Shifts and Coupling Constants for Carbon-13' of Landolt-Börnstein III/35 'Nuclear Magnetic Resonance Data', Group III 'Condensed Matter'.

  15. Correlation of magnetic resonance imaging tumor volume with histopathology.

    Science.gov (United States)

    Turkbey, Baris; Mani, Haresh; Aras, Omer; Rastinehad, Ardeshir R; Shah, Vijay; Bernardo, Marcelino; Pohida, Thomas; Daar, Dagane; Benjamin, Compton; McKinney, Yolanda L; Linehan, W Marston; Wood, Bradford J; Merino, Maria J; Choyke, Peter L; Pinto, Peter A

    2012-10-01

    The biology of prostate cancer may be influenced by the index lesion. The definition of index lesion volume is important for appropriate decision making, especially for image guided focal treatment. We determined the accuracy of magnetic resonance imaging for determining index tumor volume compared with volumes derived from histopathology. We evaluated 135 patients (mean age 59.3 years) with a mean prostate specific antigen of 6.74 ng/dl who underwent multiparametric 3T endorectal coil magnetic resonance imaging of the prostate and subsequent radical prostatectomy. Index tumor volume was determined prospectively and independently by magnetic resonance imaging and histopathology. The ellipsoid formula was applied to determine histopathology tumor volume, whereas manual tumor segmentation was used to determine magnetic resonance tumor volume. Histopathology tumor volume was correlated with age and prostate specific antigen whereas magnetic resonance tumor volume involved Pearson correlation and linear regression methods. In addition, the predictive power of magnetic resonance tumor volume, prostate specific antigen and age for estimating histopathology tumor volume (greater than 0.5 cm(3)) was assessed by ROC analysis. The same analysis was also conducted for the 1.15 shrinkage factor corrected histopathology data set. There was a positive correlation between histopathology tumor volume and magnetic resonance tumor volume (Pearson coefficient 0.633, p histopathology tumor volume (Pearson coefficient 0.237, p = 0.003). On linear regression analysis histopathology tumor volume and magnetic resonance tumor volume were correlated (r(2) = 0.401, p histopathology were 0.949 (p histopathology. Magnetic resonance imaging can accurately estimate index tumor volume as determined by histology. Magnetic resonance imaging has better accuracy in predicting histopathology tumor volume in tumors larger than 0.5 cm(3) than prostate specific antigen and age. Index tumor volume as

  16. Diffusion and Perfusion Magnetic Resonance Imaging:Fundamentals and Advances

    OpenAIRE

    Assili, Sanam

    2016-01-01

    Over the past few decades, magnetic resonance imaging has been utilized as a powerful imaging modality to evaluate the structure and function of various organs in the human body,such as the brain. Additionally, diffusion and perfusion MR imaging have been increasingly used in neurovascular clinical applications. In diffusion-weighted magnetic resonance imaging, the mobility of water molecules is explored in order to obtain information about the microscopic behavior of the tissues. In contrast...

  17. Diagnosing Autism Spectrum Disorder through Brain Functional Magnetic Resonance Imaging

    Science.gov (United States)

    2016-03-01

    Diagnosing Autism Spectrum Disorder through Brain Functional Magnetic Resonance Imaging THESIS MARCH 2016 Kyle A. Palko, Second Lieutenant, USAF AFIT...declared a work of the U.S. Government and is not subject to copyright protection in the United States. AFIT-ENC-MS-16-M-123 DIAGNOSING AUTISM SPECTRUM...PUBLIC RELEASE; DISTRIBUTION UNLIMITED. AFIT-ENC-MS-16-M-123 DIAGNOSING AUTISM SPECTRUM DISORDER THROUGH BRAIN FUNCTIONAL MAGNETIC RESONANCE IMAGING Kyle

  18. Quantification of aortic regurgitation by magnetic resonance velocity mapping

    DEFF Research Database (Denmark)

    Søndergaard, Lise; Lindvig, K; Hildebrandt, P

    1993-01-01

    The use of magnetic resonance (MR) velocity mapping in the quantification of aortic valvular blood flow was examined in 10 patients with angiographically verified aortic regurgitation. MR velocity mapping succeeded in identifying and quantifying the regurgitation in all patients, and the regurgit......The use of magnetic resonance (MR) velocity mapping in the quantification of aortic valvular blood flow was examined in 10 patients with angiographically verified aortic regurgitation. MR velocity mapping succeeded in identifying and quantifying the regurgitation in all patients...

  19. Lymphoma of uterine cervix: magnetic resonance imaging findings

    Energy Technology Data Exchange (ETDEWEB)

    Kanaan, Daniel; Constantino, Carolina Pesce Lamas; Souza, Rodrigo Canellas de, E-mail: daniel.kanaan@hotmail.com [Department of Radiology, Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil); Parente, Daniella Braz [Instituto D' Or de Pesquisa e Ensino, Rio de Janeiro, RJ (Brazil)

    2012-05-15

    Lymphoma of the cervix is a rare disease. About 1.0% to 1.5% of extranodal lymphomas originates in the female genital tract. The clinical presentation of this condition is nonspecific and magnetic resonance imaging is important for diagnostic elucidation. The present report describes the case of a 80-year-old patient with lumbar pain, whose magnetic resonance imaging showed a large uterine mass. The final diagnosis was lymphoma. (author)

  20. Magnetic Resonance Imaging Studies of Postpartum Depression: An Overview

    OpenAIRE

    Fiorelli, Marco; Aceti, Franca; Marini, Isabella; Giacchetti, Nicoletta; Macci, Enrica; Tinelli, Emanuele; Calistri, Valentina; Meuti, Valentina; Caramia, Francesca; Biondi, Massimo

    2015-01-01

    Postpartum depression is a frequent and disabling condition whose pathophysiology is still unclear. In recent years, the study of the neural correlates of mental disorders has been increasingly approached using magnetic resonance techniques. In this review we synthesize the results from studies on postpartum depression in the context of structural, functional, and spectroscopic magnetic resonance studies of major depression as a whole. Compared to the relative wealth of data available for maj...