WorldWideScience

Sample records for tendon-bone interface contact

  1. Multifunctional magnetic-responsive hydrogels to engineer tendon-to-bone interface.

    Science.gov (United States)

    Silva, Elsa D; Babo, Pedro S; Costa-Almeida, Raquel; Domingues, Rui M A; Mendes, Bárbara B; Paz, Elvira; Freitas, Paulo; Rodrigues, Márcia T; Granja, Pedro L; Gomes, Manuela E

    2017-06-11

    Photocrosslinkable magnetic hydrogels are attracting great interest for tissue engineering strategies due to their versatility and multifunctionality, including their remote controllability ex vivo, thus enabling engineering complex tissue interfaces. This study reports the development of a photocrosslinkable magnetic responsive hydrogel made of methacrylated chondroitin sulfate (MA-CS) enriched with platelet lysate (PL) with tunable features, envisioning their application in tendon-to-bone interface. MA-CS coated iron-based magnetic nanoparticles were incorporated to provide magnetic responsiveness to the hydrogel. Osteogenically differentiated adipose-derived stem cells and/or tendon-derived cells were encapsulated within the hydrogel, proliferating and expressing bone- and tendon-related markers. External magnetic field (EMF) application modulated the swelling, degradation and release of PL-derived growth factors, and impacted both cell morphology and the expression and synthesis of tendon- and bone-like matrix with a more evident effect in co-cultures. Overall, the developed magnetic responsive hydrogel represents a potential cell carrier system for interfacial tissue engineering with EMF-controlled properties. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Kartogenin with PRP promotes the formation of fibrocartilage zone in the tendon-bone interface.

    Science.gov (United States)

    Zhou, Yiqin; Zhang, Jianying; Yang, Jinsong; Narava, Manoj; Zhao, Guangyi; Yuan, Ting; Wu, Haishan; Zheng, Nigel; Hogan, MaCalus V; Wang, James H-C

    2017-12-01

    Treatment of tendon-bone junction injuries is a challenge because tendon-bone interface often heals poorly and the fibrocartilage zone, which reduces stress concentration, at the interface is not formed. In this study, we used a compound called kartogenin (KGN) with platelet-rich plasma (PRP) to induce the formation of fibrocartilage zone in a rat tendon graft-bone tunnel model. The experimental rats received KGN-PRP or PRP injections in the tendon graft-bone tunnel interface. The control group received saline. After 4, 8 and 12 weeks, Safranin O staining of the tendon graft-bone tunnels revealed abundant proteoglycans in the KGN-PRP group indicating the formation of cartilage-like transition zone. Immunohistochemical and immuno-fluorescence staining revealed collagen types I (Col-I) and II (Col-II) in the newly formed fibrocartilage zone. Both fibrocartilage zone formation and maturation were healing time dependent. In contrast, the PRP and saline control groups had no cartilage-like tissues and minimal Col-I and Col-II staining. Some gaps were also present in the saline control group. Finally, pull-out strength in the KGN-PRP-treated group at 8 weeks was 1.4-fold higher than the PRP-treated group and 1.6-fold higher than the saline control group. These findings indicate that KGN, with PRP as a carrier, promotes the formation of fibrocartilage zone between the tendon graft and bone interface. Thus, KGN-PRP may be used as a convenient cell-free therapy in clinics to promote fibrocartilage zone formation in rotator calf repair and anterior cruciate ligament reconstruction, thereby enhancing the mechanical strength of the tendon-bone interface and hence the clinical outcome of these procedures. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  3. Hydroxyapatite-doped polycaprolactone nanofiber membrane improves tendon-bone interface healing for anterior cruciate ligament reconstruction.

    Science.gov (United States)

    Han, Fei; Zhang, Peng; Sun, Yaying; Lin, Chao; Zhao, Peng; Chen, Jiwu

    2015-01-01

    Hamstring tendon autograft is a routine graft for anterior cruciate ligament (ACL) reconstruction. However, ways of improving the healing between the tendon and bone is often overlooked in clinical practice. This issue can be addressed by using a biomimetic scaffold. Herein, a biomimetic nanofiber membrane of polycaprolactone/nanohydroxyapatite/collagen (PCL/nHAp/Col) is fabricated that mimics the composition of native bone tissue for promoting tendon-bone healing. This membrane has good cytocompatibility, allowing for osteoblast cell adhesion and growth and bone formation. As a result, MC3T3 cells reveal a higher mineralization level in PCL/nHAp/Col membrane compared with PCL membrane alone. Further in vivo studies in ACL reconstruction in a rabbit model shows that PCL/nHAp/Col-wrapped tendon may afford superior tissue integration to nonwrapped tendon in the interface between the tendon and host bone as well as improved mechanical strength. This study shows that PCL/nHAp/Col nanofiber membrane wrapping of autologous tendon is effective for improving tendon healing with host bone in ACL reconstruction.

  4. Tendon Reattachment to Bone in an Ovine Tendon Defect Model of Retraction Using Allogenic and Xenogenic Demineralised Bone Matrix Incorporated with Mesenchymal Stem Cells.

    Directory of Open Access Journals (Sweden)

    Tanujan Thangarajah

    Full Text Available Tendon-bone healing following rotator cuff repairs is mainly impaired by poor tissue quality. Demineralised bone matrix promotes healing of the tendon-bone interface but its role in the treatment of tendon tears with retraction has not been investigated. We hypothesized that cortical demineralised bone matrix used with minimally manipulated mesenchymal stem cells will result in improved function and restoration of the tendon-bone interface with no difference between xenogenic and allogenic scaffolds.In an ovine model, the patellar tendon was detached from the tibial tuberosity and a complete distal tendon transverse defect measuring 1 cm was created. Suture anchors were used to reattach the tendon and xenogenic demineralised bone matrix + minimally manipulated mesenchymal stem cells (n = 5, or allogenic demineralised bone matrix + minimally manipulated mesenchymal stem cells (n = 5 were used to bridge the defect. Graft incorporation into the tendon and its effect on regeneration of the enthesis was assessed using histomorphometry. Force plate analysis was used to assess functional recovery.Compared to the xenograft, the allograft was associated with significantly higher functional weight bearing at 6 (P = 0.047, 9 (P = 0.028, and 12 weeks (P = 0.009. In the allogenic group this was accompanied by greater remodeling of the demineralised bone matrix into tendon-like tissue in the region of the defect (p = 0.015, and a more direct type of enthesis characterized by significantly more fibrocartilage (p = 0.039. No failures of tendon-bone healing were noted in either group.Demineralised bone matrix used with minimally manipulated mesenchymal stem cells promotes healing of the tendon-bone interface in an ovine model of acute tendon retraction, with superior mechanical and histological results associated with use of an allograft.

  5. Direct lentiviral-cyclooxygenase 2 application to the tendon-bone interface promotes osteointegration and enhances return of the pull-out tensile strength of the tendon graft in a rat model of biceps tenodesis.

    Directory of Open Access Journals (Sweden)

    Charles H Rundle

    Full Text Available This study sought to determine if direct application of the lentiviral (LV-cyclooxygenase 2 (COX2 vector to the tendon-bone interface would promote osteointegration of the tendon graft in a rat model of biceps tenodesis. The LV-COX2 gene transfer strategy was chosen for investigation because a similar COX2 gene transfer strategy promoted bony bridging of the fracture gap during bone repair, which involves similar histologic transitions that occur in osteointegration. Briefly, a 1.14-mm diameter tunnel was drilled in the mid-groove of the humerus of adult Fischer 344 rats. The LV-COX2 or βgal control vector was applied directly into the bone tunnel and onto the end of the tendon graft, which was then pulled into the bone tunnel. A poly-L-lactide pin was press-fitted into the tunnel as interference fixation. Animals were sacrificed at 3, 5, or 8 weeks for histology analysis of osteointegration. The LV-COX2 gene transfer strategy enhanced neo-chondrogenesis at the tendon-bone interface but with only marginal effect on de novo bone formation. The tendon-bone interface of the LV-COX2-treated tenodesis showed the well-defined tendon-to-fibrocartilage-to-bone histologic transitions that are indicative of osteointegration of the tendon graft. The LV-COX2 in vivo gene transfer strategy also significantly enhanced angiogenesis at the tendon-bone interface. To determine if the increased osteointegration was translated into an improved pull-out mechanical strength property, the pull-out tensile strength of the LV-COX2-treated tendon grafts was determined with a pull-out mechanical testing assay. The LV-COX2 strategy yielded a significant improvement in the return of the pull-out strength of the tendon graft after 8 weeks. In conclusion, the COX2-based in vivo gene transfer strategy enhanced angiogenesis, osteointegration and improved return of the pull-out strength of the tendon graft. Thus, this strategy has great potential to be developed into an

  6. In vitro investigation of a tissue-engineered cell-tendon complex mimicking the transitional architecture at the ligament-bone interface.

    Science.gov (United States)

    Wang, Zhibing; Zhang, Yuan; Zhu, Jie; Dong, Shiwu; Jiang, Tao; Zhou, Yue; Zhang, Xia

    2015-03-01

    Restoration of the transitional ligament-bone interface is critical for graft-bone integration. We postulated that an allogenic scaffold mimicking the fibrogenic, chondrogenic, and osteogenic transition gradients could physiologically promote ligament-bone incorporation. The aim of this study was to construct and characterize a composite tendon scaffold with a continuous and heterogeneous transition region mimicking a native ligament insertion site. Genetically modified heterogeneous cell populations were seeded within specific regions of decellularized rabbit Achilles tendons to fabricate a stratified scaffold containing three biofunctional regions supporting fibrogenesis, chondrogenesis, and osteogenesis. The observed morphology, architecture, cytocompatibility, and biomechanics of the scaffolds demonstrated their improved bio-physico-chemical properties. The formation of the transitional regions was augmented via enhanced delivery of two transcription factors, sex determining region Y-box 9 and runt-related transcription factor 2, which also triggered early up-regulated expression of cartilage- and bone-relevant markers, according to quantitative PCR and immunoblot analyses. Gradient tissue-specific matrix formation was also confirmed within the predesignated regions via histological staining and immunofluorescence assays. These results suggest that a transitional interface could be replicated on an engineered tendon through stratified tissue integration. The scaffold offers the advantages of a multitissue transition involving controlled cellular interactions and matrix heterogeneity, which can be applied for the regeneration of the ligament-bone interface. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  7. Rotator cuff repair with a tendon-fibrocartilage-bone composite bridging patch.

    Science.gov (United States)

    Ji, Xiaoxi; Chen, Qingshan; Thoreson, Andrew R; Qu, Jin; An, Kai-Nan; Amadio, Peter C; Steinmann, Scott P; Zhao, Chunfeng

    2015-11-01

    To compare the mechanical performance of a rotator cuff repaired with a novel tendon-fibrocartilage-bone composite bridging patch vs the traditional Mason-Allen repair in an in vitro canine model. Twenty shoulders and 10 bridging patches from patellar tendon were harvested. The patches were trimmed and sliced into 2 layers. An infraspinatus tendon tear was created in each shoulder. Modified Mason-Allen sutures were used to repair the infraspinatus tendon to the greater tuberosity, with or without the bridging patch (bridging patch group and controls, respectively). Shoulders were loaded to failure under displacement control at a rate of 0.5mm/s. The ultimate tensile load was significantly higher in the bridging patch group than control (mean [SD], 365.46 [36.45] vs 272.79 [48.88] N; Pfibrocartilage-bone composite bridging patch achieved higher ultimate tensile load and stiffness at the patch-greater tuberosity repair site compared with traditional repair in a canine model. This composite tissue transforms the traditional tendon-to-bone healing interface (with dissimilar tissues) into a pair of bone-to-bone and tendon-to-tendon interfaces, which may improve healing quality and reduce retear rate. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. Strategies to engineer tendon/ligament-to-bone interface: Biomaterials, cells and growth factors.

    Science.gov (United States)

    Font Tellado, Sonia; Balmayor, Elizabeth R; Van Griensven, Martijn

    2015-11-01

    Integration between tendon/ligament and bone occurs through a specialized tissue interface called enthesis. The complex and heterogeneous structure of the enthesis is essential to ensure smooth mechanical stress transfer between bone and soft tissues. Following injury, the interface is not regenerated, resulting in high rupture recurrence rates. Tissue engineering is a promising strategy for the regeneration of a functional enthesis. However, the complex structural and cellular composition of the native interface makes enthesis tissue engineering particularly challenging. Thus, it is likely that a combination of biomaterials and cells stimulated with appropriate biochemical and mechanical cues will be needed. The objective of this review is to describe the current state-of-the-art, challenges and future directions in the field of enthesis tissue engineering focusing on four key parameters: (1) scaffold and biomaterials, (2) cells, (3) growth factors and (4) mechanical stimuli. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. TGIF1 Gene Silencing in Tendon-Derived Stem Cells Improves the Tendon-to-Bone Insertion Site Regeneration

    Directory of Open Access Journals (Sweden)

    Liyang Chen

    2015-11-01

    Full Text Available Background/Aims: The slow healing process of tendon-to-bone junctions can be accelerated via implanted tendon-derived stem cells (TDSCs with silenced transforming growth interacting factor 1 (TGIF1 gene. Tendon-to-bone insertion site is the special form of connective tissues derivatives of common connective progenitors, where TGF-β plays bidirectional effects (chondrogenic or fibrogenic through different signaling pathways at different stages. A recent study revealed that TGF-β directly induces the chondrogenic gene Sox9. However, TGIF1 represses the expression of the cartilage master Sox9 gene and changes its expression rate against the fibrogenesis gene Scleraxis (Scx. Methods: TGIF1 siRNA was transduced or TGIF1 was over-expressed in tendon-derived stem cells. Following suprapinatus tendon repair, rats were either treated with transduced TDSCs or nontransduced TDSCs. Histologic examination and Western blot were performed in both groups. Results: In this study, the silencing of TGIF1 significantly upregulated the chondrogenic genes and markers. Similarly, TGIF1 inhibited TDSC differentiation into cartilage via interactions with TGF-β-activated Smad2 and suppressed the phosphorylation of Smad2. The area of fibrocartilage at the tendon-bone interface was significantly increased in the TGIF1 (- group compared with the control and TGIF1-overexpressing groups in the early stages of the animal model. The interface between the tendon and bone showed a increase of new bone and fibrocartilage in the TGIF1 (- group at 4 weeks. Fibrovascular scar tissue was observed in the TGIF1-overexpressing group and the fibrin glue only group. Low levels of fibrocartilage and fibrovascular scar tissue were found in the TDSCs group. Conclusion: Collectively, this study shows that the tendon-derived stem cell modified with TGIF1 gene silencing has promising effects on tendon-to-bone healing which can be further explored as a therapeutic tool in regenerative medicine.

  10. Functional grading of mineral and collagen in the attachment of tendon to bone.

    Science.gov (United States)

    Genin, Guy M; Kent, Alistair; Birman, Victor; Wopenka, Brigitte; Pasteris, Jill D; Marquez, Pablo J; Thomopoulos, Stavros

    2009-08-19

    Attachment of dissimilar materials is a major challenge because high levels of localized stress may develop at their interfaces. An effective biologic solution to this problem exists at one of nature's most extreme interfaces: the attachment of tendon (a compliant, structural "soft tissue") to bone (a stiff, structural "hard tissue"). The goal of our study was to develop biomechanical models to describe how the tendon-to-bone insertion derives its mechanical properties. We examined the tendon-to-bone insertion and found two factors that give the tendon-to-bone transition a unique grading in mechanical properties: 1), a gradation in mineral concentration, measured by Raman spectroscopy; and 2), a gradation in collagen fiber orientation, measured by polarized light microscopy. Our measurements motivate a new physiological picture of the tissue that achieves this transition, the tendon-to-bone insertion, as a continuous, functionally graded material. Our biomechanical model suggests that the experimentally observed increase in mineral accumulation within collagen fibers can provide significant stiffening of the partially mineralized fibers, but only for concentrations of mineral above a "percolation threshold" corresponding to formation of a mechanically continuous mineral network within each collagen fiber (e.g., the case of mineral connectivity extending from one end of the fiber to the other). Increasing dispersion in the orientation distribution of collagen fibers from tendon to bone is a second major determinant of tissue stiffness. The combination of these two factors may explain the nonmonotonic variation of stiffness over the length of the tendon-to-bone insertion reported previously. Our models explain how tendon-to-bone attachment is achieved through a functionally graded material composition, and provide targets for tissue engineered surgical interventions and biomimetic material interfaces.

  11. * Fabrication and Characterization of Biphasic Silk Fibroin Scaffolds for Tendon/Ligament-to-Bone Tissue Engineering.

    Science.gov (United States)

    Font Tellado, Sònia; Bonani, Walter; Balmayor, Elizabeth R; Foehr, Peter; Motta, Antonella; Migliaresi, Claudio; van Griensven, Martijn

    2017-08-01

    Tissue engineering is an attractive strategy for tendon/ligament-to-bone interface repair. The structure and extracellular matrix composition of the interface are complex and allow for a gradual mechanical stress transfer between tendons/ligaments and bone. Thus, scaffolds mimicking the structural features of the native interface may be able to better support functional tissue regeneration. In this study, we fabricated biphasic silk fibroin scaffolds designed to mimic the gradient in collagen molecule alignment present at the interface. The scaffolds had two different pore alignments: anisotropic at the tendon/ligament side and isotropic at the bone side. Total porosity ranged from 50% to 80% and the majority of pores (80-90%) were ligament, enthesis, and cartilage markers significantly changed depending on pore alignment in each region of the scaffolds. In conclusion, the biphasic scaffolds fabricated in this study show promising features for tendon/ligament-to-bone tissue engineering.

  12. Firm anchoring between a calcium phosphate-hybridized tendon and bone for anterior cruciate ligament reconstruction in a goat model

    Energy Technology Data Exchange (ETDEWEB)

    Mutsuzaki, Hirotaka [Department of Orthopaedic Surgery, Ibaraki Prefectural University of Health Sciences, 4669-2 Ami Ami-machi, Inashiki-gun, Ibaraki 300-0394 (Japan); Sakane, Masataka; Ochiai, Naoyuki [Department of Orthopaedic Surgery, Institute of Clinical Medicine, Graduate School of Comprehensive Human Sciences, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki 305-8575 (Japan); Hattori, Shinya; Kobayashi, Hisatoshi, E-mail: sakane-m@md.tsukuba.ac.j [Biomaterial Center, National Institute for Materials Science, 1-1 Namiki, Tsukuba, Ibaraki 305-0044 (Japan)

    2009-08-15

    Using an alternative soaking process improved the tendon-bone attachment for a calcium phosphate (CaP)-hybridized tendon graft. We characterized the deposited CaP on and in tendons and analyzed the histology and mechanical properties of the tendon-bone interface in anterior cruciate ligament (ACL) reconstruction in goats. The tendon grafts to be implanted were soaked ten times alternately in a Ca-containing solution and a PO{sub 4}-containing solution for 30 s each. Needlelike CaP nanocrystals including low-crystalline apatite were deposited on and between collagen fibrils from the surface to a depth of 200{mu}m inside the tendon. The structure resembles the extracellular matrix of bone. In animal experiments, the CaP-hybridized tendon directly bonded with newly formed bone at 6 weeks (n = 3), while fibrous bonding was observed in the control (n = 3). The ultimate failure load was not statistically different between the CaP (n = 7) and control (n = 7). However, in the failure mode, all the tendon-bone interfaces were intact in the CaP group, while three of seven specimens were pulled out from bone tunnels in the control. The result suggested that the strength of the tendon-bone interface in the CaP group is superior to that in the control group. Clinically, firm tendon-bone anchoring may lead to good results without the knee instability associated with the loosening of the bone-tendon junction in ACL reconstruction.

  13. Effect of the Interposition of Calcium Phosphate Materials on Tendon-Bone Healing During Repair of Chronic Rotator Cuff Tear.

    Science.gov (United States)

    Zhao, Song; Peng, Lingjie; Xie, Guoming; Li, Dingfeng; Zhao, Jinzhong; Ning, Congqin

    2014-08-01

    The current nature of tendon-bone healing after rotator cuff (RC) repair is still the formation of granulation tissue at the tendon-bone interface rather than the formation of fibrocartilage, which is the crucial structure in native tendon insertion and can be observed after knee ligament reconstruction. The interposition of calcium phosphate materials has been found to be able to enhance tendon-bone healing in knee ligament reconstruction. However, whether the interposition of these kinds of materials can enhance tendon-bone healing or even change the current nature of tendon-bone healing after RC repair still needs to be explored. The interposition of calcium phosphate materials during RC repair would enhance tendon-bone healing or change its current nature of granulation tissue formation into a more favorable process. Controlled laboratory study. A total of 144 male Sprague-Dawley rats underwent unilateral detachment of the supraspinatus tendon, followed by delayed repair after 3 weeks. The animals were allocated into 1 of 3 groups: (1) repair alone, (2) repair with Ca5(PO4)2SiO4 (CPS) bioceramic interposition, or (3) repair with hydroxyapatite (HA) bioceramic interposition at the tendon-bone interface. Animals were sacrificed at 2, 4, or 8 weeks postoperatively, and microcomputed tomography (micro-CT) was used to quantify the new bone formation at the repair site. New fibrocartilage formation and collagen organization at the tendon-bone interface was evaluated by histomorphometric analysis. Biomechanical testing of the supraspinatus tendon-bone complex was performed. Statistical analysis was performed using 1-way analysis of variance. Significance was set at P repair, CPS bioceramic significantly increased the area of fibrocartilage at the tendon-bone interface compared with the control and HA groups. Moreover, CPS and HA bioceramics had significantly improved collagen organization. Biomechanical tests indicated that the CPS and HA groups have greater ultimate

  14. Calcium-phosphate matrix with or without TGF-β3 improves tendon-bone healing after rotator cuff repair.

    Science.gov (United States)

    Kovacevic, David; Fox, Alice J; Bedi, Asheesh; Ying, Liang; Deng, Xiang-Hua; Warren, Russell F; Rodeo, Scott A

    2011-04-01

    Rotator cuff tendon heals by formation of an interposed zone of fibrovascular scar tissue. Recent studies demonstrate that transforming growth factor-beta 3 (TGF-β(3)) is associated with tissue regeneration and "scarless" healing, in contrast to scar-mediated healing that occurs with TGF-β(1). Delivery of TGF-β(3) in an injectable calcium-phosphate matrix to the healing tendon-bone interface after rotator cuff repair will result in increased attachment strength secondary to improved bone formation and collagen organization and reduced scar formation of the healing enthesis. Controlled laboratory study. Ninety-six male Sprague-Dawley rats underwent unilateral detachment of the supraspinatus tendon followed by acute repair using transosseous suture fixation. Animals were allocated into 1 of 3 groups: (1) repair alone (controls, n = 32), (2) repair augmented by application of an osteoconductive calcium-phosphate (Ca-P) matrix only (n = 32), or (3) repair augmented with Ca-P matrix + TGF-β(3) (2.75 µg) at the tendon-bone interface (n = 32). Animals were euthanized at either 2 weeks or 4 weeks postoperatively. Biomechanical testing of the supraspinatus tendon-bone complex was performed at 2 and 4 weeks (n = 8 per group). Microcomputed tomography was utilized to quantitate bone microstructure at the repair site. The healing tendon-bone interface was evaluated with histomorphometry and immunohistochemical localization of collagen types I (COLI) and III (COLIII). Statistical analysis was performed using 2-way analysis of variance with significance set at P repair site is associated with new bone formation, increased fibrocartilage, and improved collagen organization at the healing tendon-bone interface in the early postoperative period after rotator cuff repair. The addition of TGF-β(3) significantly improved strength of the repair at 4 weeks postoperatively and resulted in a more favorable COLI/COLIII ratio. The delivery of TGF-β(3) with an injectable Ca-P matrix

  15. Biology and augmentation of tendon-bone insertion repair

    OpenAIRE

    Lui, PPY; Zhang, P; Chan, KM; Qin, L

    2010-01-01

    Abstract Surgical reattachment of tendon and bone such as in rotator cuff repair, patellar-patella tendon repair and anterior cruciate ligament (ACL) reconstruction often fails due to the failure of regeneration of the specialized tissue ("enthesis") which connects tendon to bone. Tendon-to-bone healing taking place between inhomogenous tissues is a slow process compared to healing within homogenous tissue, such as tendon to tendon or bone to bone healing. Therefore special attention must be ...

  16. Biology and augmentation of tendon-bone insertion repair

    Directory of Open Access Journals (Sweden)

    Lui PPY

    2010-08-01

    Full Text Available Abstract Surgical reattachment of tendon and bone such as in rotator cuff repair, patellar-patella tendon repair and anterior cruciate ligament (ACL reconstruction often fails due to the failure of regeneration of the specialized tissue ("enthesis" which connects tendon to bone. Tendon-to-bone healing taking place between inhomogenous tissues is a slow process compared to healing within homogenous tissue, such as tendon to tendon or bone to bone healing. Therefore special attention must be paid to augment tendon to bone insertion (TBI healing. Apart from surgical fixation, biological and biophysical interventions have been studied aiming at regeneration of TBI healing complex, especially the regeneration of interpositioned fibrocartilage and new bone at the healing junction. This paper described the biology and the factors influencing TBI healing using patella-patellar tendon (PPT healing and tendon graft to bone tunnel healing in ACL reconstruction as examples. Recent development in the improvement of TBI healing and directions for future studies were also reviewed and discussed.

  17. The effects of low-intensity pulsed ultrasound on tendon-bone healing in a transosseous-equivalent sheep rotator cuff model.

    Science.gov (United States)

    Lovric, Vedran; Ledger, Michael; Goldberg, Jerome; Harper, Wade; Bertollo, Nicky; Pelletier, Matthew H; Oliver, Rema A; Yu, Yan; Walsh, William R

    2013-02-01

    The purpose of this study was to examine the effects Low-intensity Pulsed Ultrasound has on initial tendon-bone healing in a clinically relevant extra-articular transosseous-equivalent ovine rotator cuff model. Eight skeletally mature wethers, randomly allocated to either control group (n = 4) or treatment group (n = 4), underwent rotator cuff surgery following injury to the infraspinatus tendon. All animals were killed 28 days post surgery to allow examination of early effects of Low-intensity Pulsed Ultrasound treatment. General improvement in histological appearance of tendon-bone integration was noted in the treatment group. Newly formed woven bone with increased osteoblast activity along the bone surface was evident. A continuum was observed between the tendon and bone in an interdigitated fashion with Sharpey's fibres noted in the treatment group. Low-intensity Pulsed Ultrasound treatment also increased bone mineral density at the tendon-bone interface (p < 0.01), while immunohistochemistry results revealed an increase in the protein expression patterns of VEGF (p = 0.038), RUNX2 (p = 0.02) and Smad4 (p = 0.05). The results of this study indicate that Low-intensity Pulsed Ultrasound may aid in the initial phase of tendon-bone healing process in patients who have undergone rotator cuff repair. This treatment may also be beneficial following other types of reconstructive surgeries involving the tendon-bone interface.

  18. Mechanical Loading Improves Tendon-Bone Healing in a Rabbit Anterior Cruciate Ligament Reconstruction Model by Promoting Proliferation and Matrix Formation of Mesenchymal Stem Cells and Tendon Cells

    Directory of Open Access Journals (Sweden)

    Fanglong Song

    2017-02-01

    Full Text Available Background/Aims: This study investigated the effect of mechanical stress on tendon-bone healing in a rabbit anterior cruciate ligament (ACL reconstruction model as well as cell proliferation and matrix formation in co-culture of bone-marrow mesenchymal stem cells (BMSCs and tendon cells (TCs. Methods: The effect of continuous passive motion (CPM therapy on tendon-bone healing in a rabbit ACL reconstruction model was evaluated by histological analysis, biomechanical testing and gene expressions at the tendon-bone interface. Furthermore, the effect of mechanical stretch on cell proliferation and matrix synthesis in BMSC/TC co-culture was also examined. Results: Postoperative CPM therapy significantly enhanced tendon-bone healing, as evidenced by increased amount of fibrocartilage, elevated ultimate load to failure levels, and up-regulated gene expressions of Collagen I, alkaline phosphatase, osteopontin, Tenascin C and tenomodulin at the tendon-bone junction. In addition, BMSC/TC co-culture treated with mechanical stretch showed a higher rate of cell proliferation and enhanced expressions of Collagen I, Collagen III, alkaline phosphatase, osteopontin, Tenascin C and tenomodulin than that of controls. Conclusion: These results demonstrated that proliferation and differentiation of local precursor cells could be enhanced by mechanical stimulation, which results in enhanced regenerative potential of BMSCs and TCs in tendon-bone healing.

  19. Hyaluronic Acid Accelerates Tendon-to-Bone Healing After Rotator Cuff Repair.

    Science.gov (United States)

    Honda, Hirokazu; Gotoh, Masafumi; Kanazawa, Tomonoshin; Ohzono, Hiroki; Nakamura, Hidehiro; Ohta, Keisuke; Nakamura, Kei-Ichiro; Fukuda, Kanji; Teramura, Takeshi; Hashimoto, Takashi; Shichijo, Shigeki; Shiba, Naoto

    2017-12-01

    There is growing evidence that the subacromial injection of hyaluronic acid (HA) is effective for pain relief in rotator cuff tears; however, its effect on tendon-to-bone healing remains unknown. To examine the effect of HA on the chondrogenesis of mesenchymal stem cells (MSCs) in vitro and on tendon-to-bone healing in a rotator cuff repair model. Controlled laboratory study. Bilateral complete tears of the infraspinatus tendon were made in rabbits and subsequently repaired. Before closure, 1 mL HA was applied to the repaired site, and phosphate-buffered saline was used in the opposite side as a control. Biomechanical, histological, and immunohistochemical analyses were performed at 4, 8, and 12 weeks after surgery. After euthanizing each animal, the bone marrow was isolated from the femoral bone in the same rabbits. Then, MSCs were cultured in media for chondrogenic differentiation, and the chondral pellet production and cartilage-related gene expression levels in the cells were examined at various concentrations of HA. At 4 and 8 weeks after surgery, ultimate load-to-failure was significantly greater in the HA group than in the control group (45.61 ± 9.0 N vs 32.42 ± 9.4 N at 4 weeks, 90.7 ± 16.0 N vs 66.97 ± 10.0 N at 8 weeks; both P .05). Linear stiffness was not significant throughout the time point evaluation. The chondroid formation area at the tendon-bone interface stained by safranin O (control vs HA group) was 0.33% ± 0.7% versus 13.5% ± 12.3% at 4 weeks after surgery ( P repaired site stained by PicroSirius Red (control vs HA group) was 16.2 ± 10.6 versus 43.5 ± 21.3 at 4 weeks after surgery ( P .05), and 1.8% ± 4.0% versus 5.4% ± 4.2% at 12 weeks after surgery ( P > .05). Compared with the control group, HA significantly increased the volume of cartilaginous pellet produced by MSCs (0.0016 ± 0.0015 mm 3 at 0 mg/mL of HA, 0.0041 ± 0.0023 mm 3 at 1.0 mg/mL, and 0.0041 ± 0.0018 mm 3 at 4.0 mg/mL), with increased mRNA expression (relative ratio

  20. Efficient decellularization for tissue engineering of the tendon-bone interface with preservation of biomechanics.

    Directory of Open Access Journals (Sweden)

    Kai Xu

    Full Text Available Interfaces between tendon/ligament and bone ("entheses" are highly specialized tissues that allow for stress transfer between mechanically dissimilar materials. Entheses show very low regenerative capacity resulting in high incidences of failure after surgical repair. Tissue engineering is a promising approach to recover functionality of entheses. Here, we established a protocol to decellularize porcine entheses as scaffolds for enthesis tissue engineering. Chemical detergents as well as physical treatments were investigated with regard to their efficiency to decellularize 2 mm thick porcine Achilles tendon entheses. A two-phase approach was employed: study 1 investigated the effect of various concentrations of sodium dodecyl sulfate (SDS and t-octylphenoxypolyethoxy-ethanol (Triton X-100 as decellularization agents. The most efficient combination of SDS and Triton was then carried forward into study 2, where different physical methods, including freeze-thaw cycles, ultrasound, perfusion, and hydrostatic washing were used to enhance the decellularization effect. Cell counts, DNA quantification, and histology showed that washing with 0.5% SDS + 1% Triton X-100 for 72 h at room temperature could remove ~ 98% cells from the interface. Further investigation of physical methods proved that washing under 200 mmHg hydrostatic pressure shortened the detergent exposing time from 72 h to 48 h. Biomechanical tensile testing showed that the biomechanical features of treated samples were preserved. Washing under 200 mmHg hydrostatic pressure with 0.5% SDS + 1% Triton X-100 for 48 h efficiently decellularized entheses with preservation of matrix structure and biomechanical features. This protocol can be used to efficiently decellularize entheses as scaffolds for tissue engineering.

  1. Human growth hormone may be detrimental when used to accelerate recovery from acute tendon-bone interface injuries.

    Science.gov (United States)

    Baumgarten, Keith M; Oliver, Harvey A; Foley, Jack; Chen, Ding-Geng; Autenried, Peter; Duan, Shanzhong; Heiser, Patrick

    2013-05-01

    There have been few scientific studies that have examined usage of human growth hormone to accelerate recovery from injury. The hypothesis of this study was that human growth hormone would accelerate tendon-to-bone healing compared with control animals treated with placebo in a rat model of acute rotator cuff injury repair. Seventy-two rats underwent repair of acute rotator cuff injuries and were randomized into the following postoperative dosing regimens: placebo, and human growth hormone at 0.1, 1, 2, 5, and 10 mg/kg/day, administered subcutaneously once per day for fourteen days (Protocol 1). An additional twenty-four rats were randomized to receive either (1) placebo or (2) human growth hormone at 5 mg/kg, administered subcutaneously twice per day for seven days preoperatively and twenty-eight days postoperatively (Protocol 2). All rats were killed twenty-eight days postoperatively. Mechanical testing was performed. Ultimate stress, ultimate force, stiffness, energy to failure, and ultimate distension were determined. For Protocol 1, analysis of variance testing showed no significant difference between the groups with regard to ultimate stress, ultimate force, stiffness, energy to failure, or ultimate distension. In Protocol 2, ultimate force to failure was significantly worse in the human growth hormone group compared with the placebo group (21.1 ± 5.85 versus 26.3 ± 5.47 N; p = 0.035). Failure was more likely to occur through the bone than the tendon-bone interface in the human growth hormone group compared with the placebo group (p = 0.001). No significant difference was found for ultimate stress, ultimate force, stiffness, energy to failure, or ultimate distension between the groups in Protocol 2. In this rat model of acute tendon-bone injury repair, daily subcutaneous postoperative human growth hormone treatment for fourteen days failed to demonstrate a significant difference in any biomechanical parameter compared with placebo. Furthermore, subcutaneous

  2. Flexible bipolar nanofibrous membranes for improving gradient microstructure in tendon-to-bone healing.

    Science.gov (United States)

    Li, Xiaoxi; Cheng, Ruoyu; Sun, Zhiyong; Su, Wei; Pan, Guoqing; Zhao, Song; Zhao, Jinzhong; Cui, Wenguo

    2017-10-01

    Enthesis is a specialized tissue interface between the tendon and bone. Enthesis structure is very complex because of gradient changes in its composition and structure. There is currently no strategy to create a suitable environment and to regenerate the gradual-changing enthesis because of the modular complexities between two tissue types. Herein, a dual-layer organic/inorganic flexible bipolar fibrous membrane (BFM) was successfully fabricated by electrospinning to generate biomimetic non-mineralized fibrocartilage and mineralized fibrocartilage in tendon-to-bone integration of enthesis. The growth of the in situ apatite nanoparticle layer was induced on the nano hydroxyapatite-poly-l-lactic acid (nHA-PLLA) fibrous layer in simulated body solution, and the poly-l-lactic acid (PLLA) fibrous layer retained its original properties to induce tendon regeneration. The in vivo results showed that BFM significantly increased the area of glycosaminoglycan staining at the tendon-bone interface and improved collagen organization when compared to the simplex fibrous membrane (SFM) of PLLA. Implanting the bipolar membrane also induced bone formation and fibrillogenesis as assessed by micro-CT and histological analysis. Biomechanical testing showed that the BFM group had a greater ultimate load-to-failure and stiffness than the SFM group at 12weeks after surgery. Therefore, this flexible bipolar nanofibrous membrane improves the healing and regeneration process of the enthesis in rotator cuff repair. In this study, we generated a biomimetic dual-layer organic/inorganic flexible bipolar fibrous membrane by sequential electrospinning and in situ biomineralization, producing integrated bipolar fibrous membranes of PLLA fibrous membrane as the upper layer and nHA-PLLA fibrous membrane as the lower layer to mimic non-mineralized fibrocartilage and mineralized fibrocartilage in tendon-to-bone integration of enthesis. Flexible bipolar nanofibrous membranes could be easily fabricated

  3. The development and morphogenesis of the tendon-to-bone insertion What development can teach us about healing

    Science.gov (United States)

    Thomopoulos, Stavros; Genin, Guy M.; Galatz, Leesa M.

    2013-01-01

    The attachment of dissimilar materials is a major challenge because of the high levels of stress that develop at such interfaces. An effective solution to this problem develops at the attachment of tendon (a compliant “soft tissue”) to bone (a stiff “hard tissue”). This tissue, the “enthesis”, transitions from tendon to bone through gradations in structure, composition, and mechanical properties. These gradations are not regenerated during tendon-to-bone healing, leading to a high incidence of failure after surgical repair. Understanding the development of the enthesis may allow scientists to develop treatments that regenerate the natural tendon-to-bone insertion. Recent work has demonstrated that both biologic and mechanical factors drive the development and morphogenesis of the enthesis. A cascade of biologic signals similar to those seen in the growth plate promotes mineralization of cartilage on the bony end of the enthesis and the formation of fibrocartilage on the tendon end of the enthesis. Mechanical loading is also necessary for the development of the enthesis. Removal of muscle load impairs the formation of bone, fibrocartilage, and tendon at the developing enthesis. This paper reviews recent work on the development of the enthesis, with an emphasis on the roles of biologic and mechanical factors. PMID:20190378

  4. Tissue-engineering strategies for the tendon/ligament-to-bone insertion.

    Science.gov (United States)

    Smith, Lester; Xia, Younan; Galatz, Leesa M; Genin, Guy M; Thomopoulos, Stavros

    2012-01-01

    Injuries to connective tissues are painful and disabling and result in costly medical expenses. These injuries often require reattachment of an unmineralized connective tissue to bone. The uninjured tendon/ligament-to-bone insertion (enthesis) is a functionally graded material that exhibits a gradual transition from soft tissue (i.e., tendon or ligament) to hard tissue (i.e., mineralized bone) through a fibrocartilaginous transition region. This transition is believed to facilitate force transmission between the two dissimilar tissues by ameliorating potentially damaging interfacial stress concentrations. The transition region is impaired or lost upon tendon/ligament injury and is not regenerated following surgical repair or natural healing, exposing the tissue to risk of reinjury. The need to regenerate a robust tendon-to-bone insertion has led a number of tissue engineering repair strategies. This review treats the tendon-to-bone insertion site as a tissue structure whose primary role is mechanical and discusses current and emerging strategies for engineering the tendon/ligament-to-bone insertion in this context. The focus lies on strategies for producing mechanical structures that can guide and subsequently sustain a graded tissue structure and the associated cell populations.

  5. Improved Achilles tendon healing by early mechanical loading in a rabbit model.

    Science.gov (United States)

    Wang, Jihong; Jiang, Dianming; Wen, Shuzheng; Jing, Shangfei; Fan, Dongsheng; Hao, Zengtao; Han, Chaoqian

    2015-01-01

    To investigate the structure and the attachment strength of a healing tendon-bone interface and the role of mechanical loading in tendon healing. Sixty rabbits underwent unilateral detachment and repair of the Achilles tendon. Thirty animals were immobilized (Group A), and the others wereallowed loadingimmediately postoperatively (Group B). Animals were sacrificed at 4 weeks and evaluated for histological and biomechanical testing. Statistical analysis was performed with an independent t test with significance set at P = 0.05. The ultimate stress was greater in group B (4.598 ± 1.321 N/mm(2)) compared with the control group (3.388 ± 0.994 N/mm(2)) (P tendon-to-bone interface with a larger area of chondrocytes was found in group B (P tendon-to-bone interface.

  6. In vitro biomechanical comparison of three different types of single- and double-row arthroscopic rotator cuff repairs: analysis of continuous bone-tendon contact pressure and surface during different simulated joint positions.

    Science.gov (United States)

    Grimberg, Jean; Diop, Amadou; Kalra, Kunal; Charousset, Christophe; Duranthon, Louis-Denis; Maurel, Nathalie

    2010-03-01

    We assessed bone-tendon contact surface and pressure with a continuous and reversible measurement system comparing 3 different double- and single-row techniques of cuff repair with simulation of different joint positions. We reproduced a medium supraspinatus tear in 24 human cadaveric shoulders. For the 12 right shoulders, single-row suture (SRS) and then double-row bridge suture (DRBS) were used. For the 12 left shoulders, DRBS and then double-row cross suture (DRCS) were used. Measurements were performed before, during, and after knot tying and then with different joint positions. There was a significant increase in contact surface with the DRBS technique compared with the SRS technique and with the DRCS technique compared with the SRS or DRBS technique. There was a significant increase in contact pressure with the DRBS technique and DRCS technique compared with the SRS technique but no difference between the DRBS technique and DRCS technique. The DRCS technique seems to be superior to the DRBS and SRS techniques in terms of bone-tendon contact surface and pressure. Copyright 2010 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  7. Mineral distributions at the developing tendon enthesis.

    Science.gov (United States)

    Schwartz, Andrea G; Pasteris, Jill D; Genin, Guy M; Daulton, Tyrone L; Thomopoulos, Stavros

    2012-01-01

    Tendon attaches to bone across a functionally graded interface, "the enthesis". A gradient of mineral content is believed to play an important role for dissipation of stress concentrations at mature fibrocartilaginous interfaces. Surgical repair of injured tendon to bone often fails, suggesting that the enthesis does not regenerate in a healing setting. Understanding the development and the micro/nano-meter structure of this unique interface may provide novel insights for the improvement of repair strategies. This study monitored the development of transitional tissue at the murine supraspinatus tendon enthesis, which begins postnatally and is completed by postnatal day 28. The micrometer-scale distribution of mineral across the developing enthesis was studied by X-ray micro-computed tomography and Raman microprobe spectroscopy. Analyzed regions were identified and further studied by histomorphometry. The nanometer-scale distribution of mineral and collagen fibrils at the developing interface was studied using transmission electron microscopy (TEM). A zone (∼20 µm) exhibiting a gradient in mineral relative to collagen was detected at the leading edge of the hard-soft tissue interface as early as postnatal day 7. Nanocharacterization by TEM suggested that this mineral gradient arose from intrinsic surface roughness on the scale of tens of nanometers at the mineralized front. Microcomputed tomography measurements indicated increases in bone mineral density with time. Raman spectroscopy measurements revealed that the mineral-to-collagen ratio on the mineralized side of the interface was constant throughout postnatal development. An increase in the carbonate concentration of the apatite mineral phase over time suggested possible matrix remodeling during postnatal development. Comparison of Raman-based observations of localized mineral content with histomorphological features indicated that development of the graded mineralized interface is linked to endochondral

  8. Three-Dimensional Bio-Printed Scaffold Sleeves With Mesenchymal Stem Cells for Enhancement of Tendon-to-Bone Healing in Anterior Cruciate Ligament Reconstruction Using Soft-Tissue Tendon Graft.

    Science.gov (United States)

    Park, Sin Hyung; Choi, Yeong-Jin; Moon, Sang Won; Lee, Byung Hoon; Shim, Jin-Hyung; Cho, Dong-Woo; Wang, Joon Ho

    2018-01-01

    To investigate the efficacy of the insertion of 3-dimensional (3D) bio-printed scaffold sleeves seeded with mesenchymal stem cells (MSCs) to enhance osteointegration between the tendon and tunnel bone in anterior cruciate ligament (ACL) reconstruction in a rabbit model. Scaffold sleeves were fabricated by 3D bio-printing. Before ACL reconstruction, MSCs were seeded into the scaffold sleeves. ACL reconstruction with hamstring tendon was performed on both legs of 15 adult rabbits (aged 12 weeks). We implanted 15 bone tunnels with scaffold sleeves with MSCs and implanted another 15 bone tunnels with scaffold sleeves without MSCs before passing the graft. The specimens were harvested at 4, 8, and 12 weeks. H&E staining, immunohistochemical staining of type II collagen, and micro-computed tomography of the tunnel cross-sectional area were evaluated. Histologic assessment was conducted with a histologic scoring system. In the histologic assessment, a smooth bone-to-tendon transition through broad fibrocartilage formation was identified in the treatment group, and the interface zone showed abundant type II collagen production on immunohistochemical staining. Bone-tendon healing histologic scores were significantly higher in the treatment group than in the control group at all time points. Micro-computed tomography at 12 weeks showed smaller tibial (control, 9.4 ± 0.9 mm 2 ; treatment, 5.8 ± 2.9 mm 2 ; P = .044) and femoral (control, 9.6 ± 2.9 mm 2 ; treatment, 6.0 ± 1.0 mm 2 ; P = .03) bone-tunnel areas in the treated group than in the control group. The 3D bio-printed scaffold sleeve with MSCs exhibited excellent results in osteointegration enhancement between the tendon and tunnel bone in ACL reconstruction in a rabbit model. If secure biological healing between the tendon graft and tunnel bone can be induced in the early postoperative period, earlier, more successful rehabilitation may be facilitated. Three-dimensional bio-printed scaffold sleeves with

  9. Bone marrow-derived mesenchymal stem cells influence early tendon-healing in a rabbit achilles tendon model.

    Science.gov (United States)

    Chong, Alphonsus K S; Ang, Abel D; Goh, James C H; Hui, James H P; Lim, Aymeric Y T; Lee, Eng Hin; Lim, Beng Hai

    2007-01-01

    A repaired tendon needs to be protected for weeks until it has accrued enough strength to handle physiological loads. Tissue-engineering techniques have shown promise in the treatment of tendon and ligament defects. The present study tested the hypothesis that bone marrow-derived mesenchymal stem cells can accelerate tendon-healing after primary repair of a tendon injury in a rabbit model. Fifty-seven New Zealand White rabbits were used as the experimental animals, and seven others were used as the source of bone marrow-derived mesenchymal stem cells. The injury model was a sharp complete transection through the midsubstance of the Achilles tendon. The transected tendon was immediately repaired with use of a modified Kessler suture and a running epitendinous suture. Both limbs were used, and each side was randomized to receive either bone marrow-derived mesenchymal stem cells in a fibrin carrier or fibrin carrier alone (control). Postoperatively, the rabbits were not immobilized. Specimens were harvested at one, three, six, and twelve weeks for analysis, which included evaluation of gross morphology (sixty-two specimens), cell tracing (twelve specimens), histological assessment (forty specimens), immunohistochemistry studies (thirty specimens), morphometric analysis (forty specimens), and mechanical testing (sixty-two specimens). There were no differences between the two groups with regard to the gross morphology of the tendons. The fibrin had degraded by three weeks. Cell tracing showed that labeled bone marrow-derived mesenchymal stem cells remained viable and present in the intratendinous region for at least six weeks, becoming more diffuse at later time-periods. At three weeks, collagen fibers appeared more organized and there were better morphometric nuclear parameters in the treatment group (p tendon repair can improve histological and biomechanical parameters in the early stages of tendon-healing.

  10. Repeated freeze-thaw cycles reduce the survival rate of osteocytes in bone-tendon constructs without affecting the mechanical properties of tendons.

    Science.gov (United States)

    Suto, Kaori; Urabe, Ken; Naruse, Kouji; Uchida, Kentaro; Matsuura, Terumasa; Mikuni-Takagaki, Yuko; Suto, Mitsutoshi; Nemoto, Noriko; Kamiya, Kentaro; Itoman, Moritoshi

    2012-03-01

    Frozen bone-patellar tendon bone allografts are useful in anterior cruciate ligament reconstruction as the freezing procedure kills tissue cells, thereby reducing immunogenicity of the grafts. However, a small portion of cells in human femoral heads treated by standard bone-bank freezing procedures survive, thus limiting the effectiveness of allografts. Here, we characterized the survival rates and mechanisms of cells isolated from rat bones and tendons that were subjected to freeze-thaw treatments, and evaluated the influence of these treatments on the mechanical properties of tendons. After a single freeze-thaw cycle, most cells isolated from frozen bone appeared morphologically as osteocytes and expressed both osteoblast- and osteocyte-related genes. Transmission electron microscopic observation of frozen cells using freeze-substitution revealed that a small number of osteocytes maintained large nuclei with intact double membranes, indicating that these osteocytes in bone matrix were resistant to ice crystal formation. We found that tendon cells were completely killed by a single freeze-thaw cycle, whereas bone cells exhibited a relatively high survival rate, although survival was significantly reduced after three freeze-thaw cycles. In patella tendons, the ultimate stress, Young's modulus, and strain at failure showed no significant differences between untreated tendons and those subjected to five freeze-thaw cycles. In conclusion, we identified that cells surviving after freeze-thaw treatment of rat bones were predominantly osteocytes. We propose that repeated freeze-thaw cycles could be applied for processing bone-tendon constructs prior to grafting as the treatment did not affect the mechanical property of tendons and drastically reduced surviving osteocytes, thereby potentially decreasing allograft immunogenecity.

  11. Extracorporeal shockwave enhanced regeneration of fibrocartilage in a delayed tendon-bone insertion repair model.

    Science.gov (United States)

    Chow, Dick Ho Kiu; Suen, Pui Kit; Huang, Le; Cheung, Wing-Hoi; Leung, Kwok-Sui; Ng, Chun; Shi, San Qiang; Wong, Margaret Wan Nar; Qin, Ling

    2014-04-01

    Fibrous tissue is often formed in delayed healing of tendon bone insertion (TBI) instead of fibrocartilage. Extracorporeal shockwave (ESW) provides mechanical cues and upregulates expression of fibrocartilage-related makers and cytokines. We hypothesized that ESW would accelerate fibrocartilage regeneration at the healing interface in a delayed TBI healing model. Partial patellectomy with shielding at the TBI interface was performed on 32 female New Zealand White Rabbits for establishing this delayed TBI healing model. The rabbits were separated into the control and ESW group for evaluations at postoperative week 8 and 12. Shielding was removed at week 4 and a single ESW treatment was applied at week 6. Fibrocartilage regeneration was evaluated histomorphologically and immunohistochemically. Vickers hardness of the TBI matrix was measured by micro-indentation. ESW group showed higher fibrocartilage area, thickness, and proteoglycan deposition than the control in week 8 and 12. ESW increased expression of SOX9 and collagen II significantly in week 8 and 12, respectively. ESW group showed a gradual transition of hardness from bone to fibrocartilage to tendon, and had a higher Vickers hardness than the control group at week 12. In conclusion, ESW enhanced fibrocartilage regeneration at the healing interface in a delayed TBI healing model. © 2013 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  12. Anterior Cruciate Ligament Reconstruction using Bone Patellar Tendon Bone autograft in ACL deficient Knee

    Directory of Open Access Journals (Sweden)

    Navin Kumar Karn

    2015-12-01

    Full Text Available Background & Objectives: Injury to Anterior Cruciate Ligament (ACL reconstruction has increased because of increased interest in sports. There are various grafts used for reconstruction of ACL, for example, Bone Patellar Tendon Bone, Hamstring etc. The study was conducted to evaluate the results of Bone Patellar Tendon Bone graft used for reconstruction of Anterior Cruciate Ligament.Materials & Methods: 40 patients with chronic ACL deficient knee presenting to Neuro Hospital from July 2011 to June 2013 were included in the study. The patients with intraarticular fracture of knee, severe OA knee, local active or suspected infection and systemic disease that might influence the study results were excluded from the study. Bone patellar tendon bone graft was harvested from ipsilateral knee in all the cases. The patient was followed till 2 year with specified programme of rehabilitation. The pain was assessed using VAS and the function of the knee was assessed using Modified WOMAC knee index.Results: The long term satisfactory results in terms of functional stability, symptom relief and return to preinjury level of activity was seen in 32 cases (80%. Two knees got infected out of which one required arthroscopic debridement. Mean visual analogue scale was 8 and modified WOMAC knee score was 3 at 2 year follow up.Conclusion: Bone patellar tendon bone graft is useful in high demand patients and cost effective option with high patient satisfaction rate for reconstruction of ACL.JCMS Nepal. 2015;11(3:12-15.

  13. Advanced age diminishes tendon-to-bone healing in a rat model of rotator cuff repair.

    Science.gov (United States)

    Plate, Johannes F; Brown, Philip J; Walters, Jordan; Clark, John A; Smith, Thomas L; Freehill, Michael T; Tuohy, Christopher J; Stitzel, Joel D; Mannava, Sandeep

    2014-04-01

    Advanced patient age is associated with recurrent tearing and failure of rotator cuff repairs clinically; however, basic science studies have not evaluated the influence of aging on tendon-to-bone healing after rotator cuff repair in an animal model. Hypothesis/ This study examined the effect of aging on tendon-to-bone healing in an established rat model of rotator cuff repair using the aged animal colony from the National Institute on Aging of the National Institutes of Health. The authors hypothesized that normal aging decreases biomechanical strength and histologic organization at the tendon-to-bone junction after acute repair. Controlled laboratory study. In 56 F344xBN rats, 28 old and 28 young (24 and 8 months of age, respectively), the supraspinatus tendon was transected and repaired. At 2 or 8 weeks after surgery, shoulder specimens underwent biomechanical testing to compare load-to-failure and load-relaxation response between age groups. Histologic sections of the tendon-to-bone interface were assessed with hematoxylin and eosin staining, and collagen fiber organization was assessed by semiquantitative analysis of picrosirius red birefringence under polarized light. Peak failure load was similar between young and old animals at 2 weeks after repair (31% vs 26% of age-matched uninjured controls, respectively; P > .05) but significantly higher in young animals compared with old animals 8 weeks after repair (86% vs 65% of age-matched uninjured controls, respectively; P repair, fibroblasts appeared more organized and uniformly aligned in young animals on hematoxylin and eosin slides compared with old animals. Collagen birefringence analysis of the tendon-to-bone junction demonstrated that young animals had increased collagen fiber organization and similar histologic structure compared with age-matched controls (53.7 ± 2.4 gray scales; P > .05). In contrast, old animals had decreased collagen fiber organization and altered structure compared with age

  14. Free Bone Plug Quadriceps Tendon Harvest and Suspensory Button Attachment for Anterior Cruciate Ligament Reconstruction.

    Science.gov (United States)

    Todor, Adrian; Caterev, Sergiu; Nistor, Dan Viorel; Khallouki, Youssef

    2016-06-01

    The most commonly used autografts for anterior cruciate ligament reconstruction are the bone-patellar tendon-bone and hamstring tendons. Each has its advantages and limitations. The bone-patellar tendon-bone autograft can lead to more donor-site morbidity, and the hamstring autograft can be unpredictable in size. The quadriceps tendon, with or without a bone block, has been described as an alternative graft source and has been used especially in revision cases, but in recent years, it has attracted attention even for primary cases. We report a technique for harvesting a free bone quadriceps tendon graft and attaching an extracortical button for femoral fixation for anterior cruciate ligament reconstruction.

  15. The effect of platelet rich plasma from bone marrow aspirate with added bone morphogenetic protein-2 on the Achilles tendon-bone junction in rabbits.

    Science.gov (United States)

    Kim, Hak Jun; Nam, Hyok-Woo; Hur, Chang-Yong; Park, Misu; Yang, Hee Seok; Kim, Byung-Soo; Park, Jung-Ho

    2011-12-01

    To determine if exogenously injected bone marrow derived platelet-rich plasma (PRP) plus bone morphogenetic protein (BMP)-2 could accelerate the healing of bone-tendon junction injuries and increase the junction holding strength during the early regeneration period. A direct injury model of the bone-tendon junction was made using an Achilles tendon-calcaneus bone junction in a rabbit. In the PRP/BMP-2/fibrin group, 0.05 mL of bone marrow derived PRP and 100 ng/mL of BMP-2 both incorporated into 0.1 mL of fibrin glue were injected into Achilles tendon-calcaneus bone junctions. The effect of the intervention was tested by comparing the results of an intervention group to a control group. The results of biomechanical testing, and histological and gross analyses were compared between the 2 groups at the following time points after surgery: 2 weeks, 4 weeks, and 8 weeks. Histologic examinations showed that woven bone developed in tendon-bone junctions at 2 weeks after surgery in the PRP/BMP-2/fibrin group. Mechanical test results showed no significant difference between the PRP/BMP-2/fibrin and control groups at 2 and 4 weeks after surgery, but the mean maximal load in the PRP/BMP-2/fibrin group was significantly higher than in the control group (p rabbit model of tendon-bone junction injury.

  16. Articular Cartilage Increases Transition Zone Regeneration in Bone-tendon Junction Healing

    Science.gov (United States)

    Qin, Ling; Lee, Kwong Man; Leung, Kwok Sui

    2008-01-01

    The fibrocartilage transition zone in the direct bone-tendon junction reduces stress concentration and protects the junction from failure. Unfortunately, bone-tendon junctions often heal without fibrocartilage transition zone regeneration. We hypothesized articular cartilage grafts could increase fibrocartilage transition zone regeneration. Using a goat partial patellectomy repair model, autologous articular cartilage was harvested from the excised distal third patella and interposed between the residual proximal two-thirds bone fragment and tendon during repair in 36 knees. We evaluated fibrocartilage transition zone regeneration, bone formation, and mechanical strength after repair at 6, 12, and 24 weeks and compared them with direct repair. Autologous articular cartilage interposition resulted in more fibrocartilage transition zone regeneration (69.10% ± 14.11% [mean ± standard deviation] versus 8.67% ± 7.01% at 24 weeks) than direct repair at all times. There was no difference in the amount of bone formation and mechanical strength achieved. Autologous articular cartilage interposition increases fibrocartilage transition zone regeneration in bone-tendon junction healing, but additional research is required to ascertain the mechanism of stimulation and to establish the clinical applicability. PMID:18987921

  17. Structural and Ultrastructural Characteristics of Bone-Tendon Junction of the Calcaneal Tendon of Adult and Elderly Wistar Rats

    Science.gov (United States)

    Cury, Diego Pulzatto; Dias, Fernando José; Miglino, Maria Angélica; Watanabe, Ii-sei

    2016-01-01

    Tendons are transition tissues that transfer the contractile forces generated by the muscles to the bones, allowing movement. The region where the tendon attaches to the bone is called bone-tendon junction or enthesis and may be classified as fibrous or fibrocartilaginous. This study aims to analyze the collagen fibers and the cells present in the bone-tendon junction using light microscopy and ultrastructural techniques as scanning electron microscopy and transmission electron microscopy. Forty male Wistar rats were used in the experiment, being 20 adult rats at 4 months-old and 20 elderly rats at 20 months-old. The hind limbs of the rats were removed, dissected and prepared to light microscopy, transmission electron microscopy and scanning electron microscopy. The aging process showed changes in the collagen fibrils, with a predominance of type III fibers in the elderly group, in addition to a decrease in the amount of the fibrocartilage cells, fewer and shorter cytoplasmic processes and a decreased synthetic capacity due to degradation of the organelles involved in synthesis. PMID:27078690

  18. Structural and Ultrastructural Characteristics of Bone-Tendon Junction of the Calcaneal Tendon of Adult and Elderly Wistar Rats.

    Directory of Open Access Journals (Sweden)

    Diego Pulzatto Cury

    Full Text Available Tendons are transition tissues that transfer the contractile forces generated by the muscles to the bones, allowing movement. The region where the tendon attaches to the bone is called bone-tendon junction or enthesis and may be classified as fibrous or fibrocartilaginous. This study aims to analyze the collagen fibers and the cells present in the bone-tendon junction using light microscopy and ultrastructural techniques as scanning electron microscopy and transmission electron microscopy. Forty male Wistar rats were used in the experiment, being 20 adult rats at 4 months-old and 20 elderly rats at 20 months-old. The hind limbs of the rats were removed, dissected and prepared to light microscopy, transmission electron microscopy and scanning electron microscopy. The aging process showed changes in the collagen fibrils, with a predominance of type III fibers in the elderly group, in addition to a decrease in the amount of the fibrocartilage cells, fewer and shorter cytoplasmic processes and a decreased synthetic capacity due to degradation of the organelles involved in synthesis.

  19. Extrusion of bone anchor suture following flexor digitorum profundus tendon avulsion injury repair.

    LENUS (Irish Health Repository)

    Tiong, William H C

    2011-09-01

    Flexor digitorum profundus (FDP) zone I tendon avulsion injury is traditionally repaired with a pullout suture technique. More recently, bone anchor sutures have been used as a viable alternative and have largely replaced areas in hand surgery where pullout suture technique was once required. To date, there have been very few complications reported related to bone anchor suture use in FDP tendon reattachment to the bone. We report a very unusual case of extrusion of bone anchor through the nailbed, 6 years after zone I FDP tendon avulsion injury repair and a brief review of literature.

  20. Feasibility Verification of Mountable PZT-Interface for Impedance Monitoring in Tendon-Anchorage

    Directory of Open Access Journals (Sweden)

    Thanh-Canh Huynh

    2015-01-01

    Full Text Available This study has been motivated to numerically evaluate the performance of the mountable PZT-interface for impedance monitoring in tendon-anchorage. Firstly, electromechanical impedance monitoring and feature classification methods are outlined. Secondly, a structural model of tendon-anchorage subsystem with mountable PZT-interface is designed for impedance monitoring. Finally, the feasibility of the mountable PZT-interface is numerically examined. A finite element (FE model is designed for the lab-scaled tendon-anchorage. The FE model of the PZT-interface is tuned as its impedance signatures meet the experimental test results at the same frequency ranges and also with identical patterns. Equivalent model properties of the FE model corresponding to prestress forces inflicted on the lab-tested structure are identified from the fine-tuning practice.

  1. Effects of low-intensity pulsed ultrasound on new trabecular bone during bone-tendon junction healing in a rabbit model: a synchrotron radiation micro-CT study.

    Directory of Open Access Journals (Sweden)

    Hongbin Lu

    Full Text Available This study was designed to evaluate the effects of low-intensity pulsed ultrasound on bone regeneration during the bone-tendon junction healing process and to explore the application of synchrotron radiation micro computed tomography in three dimensional visualization of the bone-tendon junction to evaluate the microarchitecture of new trabecular bone. Twenty four mature New Zealand rabbits underwent partial patellectomy to establish a bone-tendon junction injury model at the patella-patellar tendon complex. Animals were then divided into low-intensity pulsed ultrasound treatment (20 min/day, 7 times/week and placebo control groups, and were euthanized at week 8 and 16 postoperatively (n = 6 for each group and time point. The patella-patellar tendon specimens were harvested for radiographic, histological and synchrotron radiation micro computed tomography detection. The area of the newly formed bone in the ultrasound group was significantly greater than that of control group at postoperative week 8 and 16. The high resolution three dimensional visualization images of the bone-tendon junction were acquired by synchrotron radiation micro computed tomography. Low-intensity pulsed ultrasound treatment promoted dense and irregular woven bone formation at week 8 with greater bone volume fraction, number and thickness of new trabecular bone but with lower separation. At week 16, ultrasound group specimens contained mature lamellar bone with higher bone volume fraction and thicker trabeculae than that of control group; however, there was no significant difference in separation and number of the new trabecular bone. This study confirms that low-intensity pulsed ultrasound treatment is able to promote bone formation and remodeling of new trabecular bone during the bone-tendon junction healing process in a rabbit model, and the synchrotron radiation micro computed tomography could be applied for three dimensional visualization to quantitatively evaluate

  2. A biomechanical comparison of tendon-bone interface motion and cyclic loading between single-row, triple-loaded cuff repairs and double-row, suture-tape cuff repairs using biocomposite anchors.

    Science.gov (United States)

    Barber, F Alan; Drew, Otis R

    2012-09-01

    To compare tendon-bone interface motion and cyclic loading in a single-row, triple-loaded anchor repair with a suture-tape, rip-stop, double-row rotator cuff repair. Using 18 human shoulders from 9 matched cadaveric pairs, we created 2 groups of rotator cuff repairs. Group 1 was a double-row, rip-stop, suture-tape construct. Group 2 was a single-row, triple-loaded construct. Before mechanical testing, the supraspinatus footprint was measured with calipers. A superiorly positioned digital camera optically measured the tendon footprint motion during 60° of humeral internal and external rotation. Specimens were secured at a fixed angle not exceeding 45° in reference to the load. After preloading, each sample was cycled between 10 N and 100 N for 200 cycles at 1 Hz, followed by destructive testing at 33 mm/s. A digital camera with tracking software measured the repair displacement at 100 and 200 cycles. Ultimate load and failure mode for each sample were recorded. The exposed anterior footprint border (6.5% ± 6%) and posterior footprint border (0.9% ± 1.7%) in group 1 were statistically less than the exposed anterior footprint border (30.3% ± 17%) and posterior footprint border (29.8% ± 14%) in group 2 (P = .003 and P row rotator cuff repair had greater footprint coverage, less rotational footprint displacement, and a greater mean ultimate failure load than the triple-loaded, single-row repair on mechanical testing. No double-row or single-row constructs showed 5 mm of displacement after the first 100 cycles. The most common failure mode for both constructs was suture tearing through the tendon. Differences in cuff fixation influence rotational tendon movement and may influence postoperative healing. Stronger repair constructs still fail at the suture-tendon interface. Copyright © 2012 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  3. Quantification of temperature effect on impedance monitoring via PZT interface for prestressed tendon anchorage

    Science.gov (United States)

    Huynh, Thanh-Canh; Kim, Jeong-Tae

    2017-12-01

    In this study, the quantification of temperature effect on impedance monitoring via a PZT interface for prestressed tendon-anchorage is presented. Firstly, a PZT interface-based impedance monitoring technique is selected to monitor impedance signatures by predetermining sensitive frequency bands. An analytical model is designed to represent coupled dynamic responses of the PZT interface-tendon anchorage system. Secondly, experiments on a lab-scaled tendon anchorage are described. Impedance signatures are measured via the PZT interface for a series of temperature and prestress-force changes. Thirdly, temperature effects on measured impedance responses of the tendon anchorage are estimated by quantifying relative changes in impedance features (such as RMSD and CCD indices) induced by temperature variation and prestress-force change. Finally, finite element analyses are conducted to investigate the mechanism of temperature variation and prestress-loss effects on the impedance responses of prestressed tendon anchorage. Temperature effects on impedance monitoring are filtered by effective frequency shift-based algorithm for distinguishing prestress-loss effects on impedance signatures.

  4. Composition and structure of porcine digital flexor tendon-bone insertion tissues.

    Science.gov (United States)

    Chandrasekaran, Sandhya; Pankow, Mark; Peters, Kara; Huang, Hsiao-Ying Shadow

    2017-11-01

    Tendon-bone insertion is a functionally graded tissue, transitioning from 200 MPa tensile modulus at the tendon end to 20 GPa tensile modulus at the bone, across just a few hundred micrometers. In this study, we examine the porcine digital flexor tendon insertion tissue to provide a quantitative description of its collagen orientation and mineral concentration by using Fast Fourier Transform (FFT) based image analysis and mass spectrometry, respectively. Histological results revealed uniformity in global collagen orientation at all depths, indicative of mechanical anisotropy, although at mid-depth, the highest fiber density, least amount of dispersion, and least cellular circularity were evident. Collagen orientation distribution obtained through 2D FFT of histological imaging data from fluorescent microscopy agreed with past measurements based on polarized light microscopy. Results revealed global fiber orientation across the tendon-bone insertion to be preserved along direction of physiologic tension. Gradation in the fiber distribution orientation index across the insertion was reflective of a decrease in anisotropy from the tendon to the bone. We provided elemental maps across the fibrocartilage for its organic and inorganic constituents through time-of-flight secondary ion mass spectrometry (TOF-SIMS). The apatite intensity distribution from the tendon to bone was shown to follow a linear trend, supporting past results based on Raman microprobe analysis. The merit of this study lies in the image-based simplified approach to fiber distribution quantification and in the high spatial resolution of the compositional analysis. In conjunction with the mechanical properties of the insertion tissue, fiber, and mineral distribution results for the insertion from this may potentially be incorporated into the development of a structural constitutive approach toward computational modeling. Characterizing the properties of the native insertion tissue would provide the

  5. Effect of Platelet-Rich Plasma and Bioactive Glass Powder for the Improvement of Rotator Cuff Tendon-to-Bone Healing in a Rabbit Model

    Directory of Open Access Journals (Sweden)

    Yang Wu

    2014-11-01

    Full Text Available To test the hypothesis that a platelet-rich plasma (PRP plus bioactive glass (BG mixture could shorten the tendon-bone healing process in rotator cuff tendon repair, thirty mature male New Zealand white rabbits were randomly divided into three groups, Control, PRP, and PRP + BG. All groups underwent a surgical procedure to establish a rotator cuff tendon healing model. Mechanical examinations and histological assays were taken to verify the adhesion of the tendon-bone. Real-time PCR was adopted to analyze Bone Morphogenetic Protein-2 (BMP-2. The maximum load-to-failure value in mechanical examinations was significantly higher in the PRP + BG group than that in the control group after six weeks (Control 38.73 ± 8.58, PRP 54.49 ± 8.72, PRP + BG 79.15 ± 7.62, p < 0.001, but it was not significantly different at 12 weeks (PRP 74.27 ± 7.74, PRP + BG 82.57 ± 6.63, p = 0.145. In histological assays, H&E (hematoxylin-eosin staining showed that the interface between the tendon-bone integration was much sturdier in the PRP + BG group compared to the other two groups at each time point, and more ordered arranged tendon fibers can be seen at 12 weeks. At six weeks, the mRNA expression levels of BMP-2 in the PRP + BG group were higher than those in the other groups (PRP + BG 0.65 ± 0.11, PRP 2.284 ± 0.07, Control 0.12 ± 0.05, p < 0.05. However, there was no significant difference in the mRNA expression levels of BMP-2 among the three groups at 12 weeks (p = 0.922, 0.067, 0.056. BMP-2 levels in PRP and PRP+BG groups were significantly lower at 12 weeks compared to six weeks (p = 0.006, <0.001.We found that the PRP + BG mixture could enhance tendon-bone healing in rotator cuff tendon repair.

  6. Contact damage failure analyses of fretting wear behavior of the metal stem titanium alloy-bone cement interface.

    Science.gov (United States)

    Zhang, Lanfeng; Ge, Shirong; Liu, Hongtao; Wang, Qingliang; Wang, Liping; Xian, Cory J

    2015-11-01

    Although cemented titanium alloy is not favored currently in the Western world for its poor clinical and radiography outcomes, its lower modulus of elasticity and good biocompatibility are instrumental for its ability supporting and transforming physical load, and it is more suitable for usage in Chinese and Japanese populations due to their lower body weights and unique femoral characteristics. Through various friction tests of different cycles, loads and conditions and by examining fretting hysteresis loops, fatigue process curves and wear surfaces, the current study investigated fretting wear characteristics and wear mechanism of titanium alloy stem-bone cement interface. It was found that the combination of loads and displacement affected the wear quantity. Friction coefficient, which was in an inverse relationship to load under the same amplitude, was proportional to amplitudes under the same load. Additionally, calf serum was found to both lubricate and erode the wear interface. Moreover, cement fatigue contact areas appeared black/oxidative in dry and gruel in 25% calf serum. Fatigue scratches were detected within contact areas, and wear scars were found on cement and titanium surfaces, which were concave-shaped and ring concave/ convex-shaped, respectively. The coupling of thermoplastic effect and minimal torque damage has been proposed to be the major reason of contact damage. These data will be important for further studies analyzing metal-cement interface failure performance and solving interface friction and wear debris production issues. Copyright © 2015 Elsevier Ltd. All rights reserved.

  7. The Improvement of Bone-Tendon Fixation by Porous Titanium Interference Screw: A Rabbit Animal Model.

    Science.gov (United States)

    Tsai, Pei-I; Chen, Chih-Yu; Huang, Shu-Wei; Yang, Kuo-Yi; Lin, Tzu-Hung; Chen, San-Yuan; Sun, Jui-Sheng

    2018-05-04

    The interference screw is a widely used fixation device in the anterior cruciate ligament (ACL) reconstruction surgeries. Despite the generally satisfactory results, problems of using interference screws were reported. By using additive manufacturing (AM) technology, we developed an innovative titanium alloy (Ti 6 Al 4 V) interference screw with rough surface and inter-connected porous structure designs to improve the bone-tendon fixation. An innovative Ti 6 Al 4 V interference screws were manufactured by AM technology. In vitro mechanical tests were performed to validate its mechanical properties. Twenty-seven New Zealand white rabbits were randomly divided into control and AM screw groups for biomechanical analyses and histological analysis at 4, 8 and 12 weeks postoperatively; while micro-CT analysis was performed at 12 weeks postoperatively. The biomechanical tests showed that the ultimate failure load in the AM interference screw group was significantly higher than that in the control group at all tested periods. These results were also compatible with the findings of micro-CT and histological analyses. In micro-CT analysis, the bone-screw gap was larger in the control group; while for the additive manufactured screw, the screw and bone growth was in close contact. In histological study, the bone-screw gaps were wider in the control group and were almost invisible in the AM screw group. The innovative AM interference screws with surface roughness and inter-connected porous architectures demonstrated better bone-tendon-implant integration, and resulted in stronger biomechanical characteristics when compared to traditional screws. These advantages can be transferred to future interference screw designs to improve their clinical performance. The AM interference screw could improve graft fixation and eventually result in better biomechanical performance of the bone-tendon-screw construct. The innovative AM interference screws can be transferred to future

  8. Engineering the bone-ligament interface using polyethylene glycol diacrylate incorporated with hydroxyapatite.

    Science.gov (United States)

    Paxton, Jennifer Z; Donnelly, Kenneth; Keatch, Robert P; Baar, Keith

    2009-06-01

    Ligaments and tendons have previously been tissue engineered. However, without the bone attachment, implantation of a tissue-engineered ligament would require it to be sutured to the remnant of the injured native tissue. Due to slow repair and remodeling, this would result in a chronically weak tissue that may never return to preinjury function. In contrast, orthopaedic autograft reconstruction of the ligament often uses a bone-to-bone technique for optimal repair. Since bone-to-bone repairs heal better than other methods, implantation of an artificial ligament should also occur from bone-to-bone. The aim of this study was to investigate the use of a poly(ethylene glycol) diacrylate (PEGDA) hydrogel incorporated with hydroxyapatite (HA) and the cell-adhesion peptide RGD (Arg-Gly-Asp) as a material for creating an in vitro tissue interface to engineer intact ligaments (i.e., bone-ligament-bone). Incorporation of HA into PEG hydrogels reduced the swelling ratio but increased mechanical strength and stiffness of the hydrogels. Further, HA addition increased the capacity for cell growth and interface formation. RGD incorporation increased the swelling ratio but decreased mechanical strength and stiffness of the material. Optimum levels of cell attachment were met using a combination of both HA and RGD, but this material had no better mechanical properties than PEG alone. Although adherence of the hydrogels containing HA was achieved, failure occurs at about 4 days with 5% HA. Increasing the proportion of HA improved interface formation; however, with high levels of HA, the PEG HA composite became brittle. This data suggests that HA, by itself or with other materials, might be well suited for engineering the ligament-bone interface.

  9. Mechanical properties of human bone-tendon-bone grafts preserved by different methods and radiation sterilised

    International Nuclear Information System (INIS)

    Kaminski, A.; Gut, G.

    2008-01-01

    Full text: Patellar tendon auto and allografts are commonly used in orthopaedic surgery for reconstruction of the anterior crucial ligaments (ACL). Autografts are mainly used for primary reconstruction, while allografts are useful for revision surgery. To avoid the risk of infection diseases transmission allografts should be radiation-sterilised. As radiation-sterilisation is supposed to decrease the mechanical strength of tendon tissue, it is important to establish methods of allografts preservation and sterilisation resulting in their best quality and safety. Therefore, the purpose of the study was to compare the tensile strength of the central one third of human patellar tendon (as used for ACL reconstruction), preserved by different methods (deep fresh freezing, lyophilisation) and subsequently radiation-sterilised with doses of 0 (control), 25, 50 or 100 kGy. Bone-tendon-bone grafts were prepared from cadaveric human patella tendon with both patellar and tibial attachments. BTB grafts were preserved by deep freezing, glicerolisation or lyophilisation and radiation-sterilised with doses of 0 (control), 25, 50 or 100 kGy. To estimate mechanical properties all samples were subjected to tensile tests to failure using Instron system. Before these tests all lyophilised grafts were rehydrated. We found decrease of tensile strength of irradiated grafts compared to non-irradiated controls. Obtained results of the mechanical testing of studied grafts indicate their potential usefulness for clinical applications.(Author)

  10. Next Generation Tissue Engineering of Orthopedic Soft Tissue-to-Bone Interfaces

    Science.gov (United States)

    Boys, Alexander J.; McCorry, Mary Clare; Rodeo, Scott; Bonassar, Lawrence J.; Estroff, Lara A.

    2017-01-01

    Soft tissue-to-bone interfaces are complex structures that consist of gradients of extracellular matrix materials, cell phenotypes, and biochemical signals. These interfaces, called entheses for ligaments, tendons, and the meniscus, are crucial to joint function, transferring mechanical loads and stabilizing orthopedic joints. When injuries occur to connected soft tissue, the enthesis must be re-established to restore function, but due to structural complexity, repair has proven challenging. Tissue engineering offers a promising solution for regenerating these tissues. This prospective review discusses methodologies for tissue engineering the enthesis, outlined in three key design inputs: materials processing methods, cellular contributions, and biochemical factors. PMID:29333332

  11. Enhancement of tendon–bone healing via the combination of biodegradable collagen-loaded nanofibrous membranes and a three-dimensional printed bone-anchoring bolt

    Directory of Open Access Journals (Sweden)

    Chou YC

    2016-08-01

    Full Text Available Ying-Chao Chou,1,2 Wen-Lin Yeh,2 Chien-Lin Chao,1 Yung-Heng Hsu,1,2 Yi-Hsun Yu,1,2 Jan-Kan Chen,3 Shih-Jung Liu1,2 1Department of Mechanical Engineering, Chang Gung University, 2Department of Orthopedic Surgery, Chang Gung Memorial Hospital, 3Department of Physiology and Pharmacology, Chang Gung University, Taoyuan, Taiwan Abstract: A composite biodegradable polymeric model was developed to enhance tendon graft healing. This model included a biodegradable polylactide (PLA bolt as the bone anchor and a poly(D,L-lactide-co-glycolide (PLGA nanofibrous membrane embedded with collagen as a biomimic patch to promote tendon–bone interface integration. Degradation rate and compressive strength of the PLA bolt were measured after immersion in a buffer solution for 3 months. In vitro biochemical characteristics and the nanofibrous matrix were assessed using a water contact angle analyzer, pH meter, and tetrazolium reduction assay. In vivo efficacies of PLGA/collagen nanofibers and PLA bolts for tendon–bone healing were investigated on a rabbit bone tunnel model with histological and tendon pullout tests. The PLGA/collagen-blended nanofibrous membrane was a hydrophilic, stable, and biocompatible scaffold. The PLA bolt was durable for tendon–bone anchoring. Histology showed adequate biocompatibility of the PLA bolt on a medial cortex with progressive bone ingrowth and without tissue overreaction. PLGA nanofibers within the bone tunnel also decreased the tunnel enlargement phenomenon and enhanced tendon–bone integration. Composite polymers of the PLA bolt and PLGA/collagen nanofibrous membrane can effectively promote outcomes of tendon reconstruction in a rabbit model. The composite biodegradable polymeric system may be useful in humans for tendon reconstruction. Keywords: polylactide–polyglycolide nanofibers, PLGA, collagen, 3D printing, polylactide, PLA, bone-anchoring bolts, tendon healing

  12. Engineering Musculoskeletal Tissue Interfaces

    Directory of Open Access Journals (Sweden)

    Ece Bayrak

    2018-04-01

    Full Text Available Tissue engineering aims to bring together biomaterials, cells, and signaling molecules within properly designed microenvironments in order to create viable treatment options for the lost or malfunctioning tissues. Design and production of scaffolds and cell-laden grafts that mimic the complex structural and functional features of tissues are among the most important elements of tissue engineering strategy. Although all tissues have their own complex structure, an even more complex case in terms of engineering a proper carrier material is encountered at the tissue interfaces, where two distinct tissues come together. The interfaces in the body can be examined in four categories; cartilage-bone and ligament-bone interfaces at the knee and the spine, tendon-bone interfaces at the shoulder and the feet, and muscle-tendon interface at the skeletal system. These interfaces are seen mainly at the soft-to-hard tissue transitions and they are especially susceptible to injury and tear due to the biomechanical inconsistency between these tissues where high strain fields are present. Therefore, engineering the musculoskeletal tissue interfaces remain a challenge. This review focuses on recent advancements in strategies for musculoskeletal interface engineering using different biomaterial-based platforms and surface modification techniques.

  13. Use of a strontium-enriched calcium phosphate cement in accelerating the healing of soft-tissue tendon graft within the bone tunnel in a rabbit model of anterior cruciate ligament reconstruction.

    Science.gov (United States)

    Kuang, G M; Yau, W P; Lu, W W; Chiu, K Y

    2013-07-01

    We investigated whether strontium-enriched calcium phosphate cement (Sr-CPC)-treated soft-tissue tendon graft results in accelerated healing within the bone tunnel in reconstruction of the anterior cruciate ligament (ACL). A total of 30 single-bundle ACL reconstructions using tendo Achillis allograft were performed in 15 rabbits. The graft on the tested limb was treated with Sr-CPC, whereas that on the contralateral limb was untreated and served as a control. At timepoints three, six, nine, 12 and 24 weeks after surgery, three animals were killed for histological examination. At six weeks, the graft-bone interface in the control group was filled in with fibrovascular tissue. However, the gap in the Sr-CPC group had already been completely filled in with new bone, and there was evidence of the early formation of Sharpey fibres. At 24 weeks, remodelling into a normal ACL-bone-like insertion was found in the Sr-CPC group. Coating of Sr-CPC on soft tissue tendon allograft leads to accelerated graft healing within the bone tunnel in a rabbit model of ACL reconstruction using Achilles tendon allograft.

  14. TOB1 Deficiency Enhances the Effect of Bone Marrow-Derived Mesenchymal Stem Cells on Tendon-Bone Healing in a Rat Rotator Cuff Repair Model

    Directory of Open Access Journals (Sweden)

    Yulei Gao

    2016-01-01

    Full Text Available Background/Aims: This study investigated the effect of silencing TOB1 (Transducer of ERBB2, 1 expression in bone marrow-derived mesenchymal stem cells (MSCs on MSC-facilitated tendon-bone healing in a rat supraspinatus repair model. Methods: Rat MSCs were transduced with a recombinant lentivirus encoding short hairpin RNA (shRNA against TOB1. MSC cell proliferation was analyzed by 3-(4,5-dimethylthiazol-2-yl-2,5-diphenyltetrazolium bromide (MTT assays. The effect of MSCs with TOB1 deficiency on tendon-bone healing in a rat rotator cuff repair model was evaluated by biomechanical testing, histological analysis and collagen type I and II gene expression. An upstream regulator (miR-218 of TOB1 was determined in MSCs. Results: We found that knockdown of TOB1 significantly increased the proliferative activity of rat MSCs in vitro. When MSCs with TOB1 deficiency were injected into injured rat supraspinatus tendon-bone junctions, the effect on tendon-bone healing was enhanced compared to treatment with control MSCs with normal TOB1 expression, as evidenced by elevated levels of ultimate load to failure and stiffness, increased amount of fibrocartilage and augmented expression of collagen type I and type II genes. In addition, we found that the TOB1 3′ untranslated region is a direct target of miR-218. Similar to the effect of TOB1 deficiency, overexpression of miR-218 effectively promoted tendon-bone healing in rat. Conclusion: These results suggest that TOB1 may play a negative role in the effect of MSCs on tendon-bone healing, and imply that expression of TOB1 may be regulated by miR-218.

  15. [Three-dimensional finite element analysis on mechanical behavior of the bone remodeling and bone integration between the bone-implant interface after hip replacement].

    Science.gov (United States)

    Li, Yong-Jiang; Zhang, Li-Cheng; Zhang, Mei-Chao; Yang, Guo-Jing; Lin, Rui-Xin; Cai, Chun-Yuan; Zhong, Shi-Zhen

    2014-04-01

    To discuss the primary stability of the fixed interface between the cementless prosthesis and femur, and its influence on bone ingrowth and secondary stability under the roughened surface and press fit of different prostheses by finite element analysis. :A three-dimensional finite element module of total hip arthroplasty (THA) was developed with Mimics software. There was a collection of data when simulating hip arthroplasty. The frictional coefficient between the fixed interface was 0,0.15,0.40 and 1.00 representing the roughness of prosthesis surface. The press fit was 0, 0.01,0.05 and 0.10 mm according to the operation. The Vion Mises stress distribution and the contact pressure,friction stress and relative sliding displacement between the interface were analysed and compared when simulating the maneuver of climbing stairs. At a fixed press fit of 0.05 mm,the contact pressure between the interface was 230 , 231, 222 and 275 MN under four different frictional coefficient (0,0. 15,0.40 and 1.00) with little change; the relative sliding displacement was 0.529, 0.129, 0.107 and 0.087 mm with a consistent and obvious decline. As the fixed frictional coefficient was 0.40,the contact pressure between the interface were 56.0,67.7 ,60.4 and 49.6 MN under four different press fit (0, 0.01, 0.05 and 0.10 mm) with a reduction; the relative sliding displacement was 0.064,0.062,0.043 and 0.042 mm with an obvious decline, and there was a maximal friction stress when press fit of 0.01 mm. There is a dynamic process of the bone remodeling and bone integration between the interface after hip replacement, determining the long-term outcome. The interface clearance and the frictional coefficient are the key factors of the bone integration.

  16. Early integration of a bone plug in the femoral tunnel in rectangular tunnel ACL reconstruction with a bone-patellar tendon-bone graft: a prospective computed tomography analysis.

    Science.gov (United States)

    Suzuki, Tomoyuki; Shino, Konsei; Nakagawa, Shigeto; Nakata, Ken; Iwahashi, Takehiko; Kinugasa, Kazutaka; Otsubo, Hidenori; Yamashita, Toshihiko

    2011-12-01

    The purpose of this prospective study was to evaluate how early the bone plug was integrated into the rectangular femoral tunnel after anatomical ACL reconstruction using a bone-patellar tendon-bone (BTB) graft via a rectangular tunnel (RT BTB ACL-R). Twenty consecutive patients who had undergone the reconstruction procedure were evaluated by CT scans at 4 and 8 weeks postoperatively. In each scan, 30 slices for multiplanar reconstruction were collected parallel to the long axis of the parallelepiped femoral tunnel and perpendicular to the tendinous plane of the bone plug. Each slice was classified as "complete," indicating no visible gap between the plug and the tunnel wall or trabecular continuity or "incomplete," showing a visible gap. Bone plug-tunnel integration was evaluated as "excellent," "good," "fair," or "poor" for >20, 11-20, 5-10, and values at the anterior interface between the bone plug and the tunnel wall were also measured on both scans. The mean changes in CT value at 8 weeks were significantly lower than those at 4 weeks. This study shows that bone plug-femoral tunnel integration was almost complete by 8 weeks after surgery using RT BTB ACL-R.

  17. Comparison of a novel bone-tendon allograft with a human dermis-derived patch for repair of chronic large rotator cuff tears using a canine model.

    Science.gov (United States)

    Smith, Matthew J; Cook, James L; Kuroki, Keiichi; Jayabalan, Prakash S; Cook, Cristi R; Pfeiffer, Ferris M; Waters, Nicole P

    2012-02-01

    This study tested a bone-tendon allograft versus human dermis patch for reconstructing chronic rotator cuff repair by use of a canine model. Mature research dogs (N = 15) were used. Radiopaque wire was placed in the infraspinatus tendon (IST) before its transection. Three weeks later, radiographs showed IST retraction. Each dog then underwent 1 IST treatment: debridement (D), direct repair of IST to bone with a suture bridge and human dermis patch augmentation (GJ), or bone-tendon allograft (BT) reconstruction. Outcome measures included lameness grading, radiographs, and ultrasonographic assessment. Dogs were killed 6 months after surgery and both shoulders assessed biomechanically and histologically. BT dogs were significantly (P = .01) less lame than the other groups. BT dogs had superior bone-tendon, tendon, and tendon-muscle integrity compared with D and GJ dogs. Biomechanical testing showed that the D group had significantly (P = .05) more elongation than the other groups whereas BT had stiffness and elongation characteristics that most closely matched normal controls. Radiographically, D and GJ dogs showed significantly more retraction than BT dogs (P = .003 and P = .045, respectively) Histologically, GJ dogs had lymphoplasmacytic infiltrates, tendon degeneration and hypocellularity, and poor tendon-bone integration. BT dogs showed complete incorporation of allograft bone into host bone, normal bone-tendon junctions, and well-integrated allograft tendon. The bone-tendon allograft technique re-establishes a functional IST bone-tendon-muscle unit and maintains integrity of repair in this model. Clinical trials using this bone-tendon allograft technique are warranted. Copyright © 2012 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  18. Press-fit Femoral Fixation in ACL Reconstruction using Bone-Patellar Tendon-Bone Graft

    Directory of Open Access Journals (Sweden)

    Kaseb Mohammad Hasan

    2009-05-01

    Full Text Available Bone-patellar tendon auto graft is probably the most widely used graft for ACL reconstruction. Several methods for graft fixation have been described. To avoid intra-articular hardware we adopt biological fixation with a femoral trapezoidal press-fit fixation. A prospective study was performed on 30 consecutive active people who underwent ACL reconstruction with this technique by two surgeons between september2004 and march2007 (mean follow-up 15.2 months. Results were evaluated by an independent examiner using radiography, subjective and objective evaluation. Assessment using the IKDC knee scoring revealed 92% of the patients with a normal or nearly normal knee joint. Lysholm's score was 63.6(40- 86 preoperatively and 91.88(73-100 at the latest follow up (P < 0.005. No patient complained of instability at latest follow up. The quadriceps muscle showed mild atrophy at 3 and 6 months and at final follow-up. Five Patients complained of anterior knee pain and had a positive kneeling test. We found no graft displacement on follow up radiographs. All cases showed radiological evidence of graft osteointegration at last follow up. Our results show that press-fit fixation of trapezoidal bone graft in femoral tunnel is a simple, reliable, and cost-effective alternative for ACL recon-struction using bone-patellar tendon-bone graft.

  19. Enhanced Tendon-to-Bone Healing of Chronic Rotator Cuff Tears by Bone Marrow Aspirate Concentrate in a Rabbit Model

    Science.gov (United States)

    Liu, Xiao Ning; Yang, Cheol-Jung; Kim, Ji Eui; Du, Zhen Wu; Ren, Ming; Zhang, Wei; Zhao, Hong Yu; Kim, Kyung Ok

    2018-01-01

    Background To evaluate the influence of bone marrow aspirate concentrate (BMAC) on tendon-to-bone healing in a rabbit rotator cuff model and to characterize the composition of growth factors in BMAC. Methods In this in vivo study, 40 rabbits were allocated into five groups: control (C), repair + saline (RS), repair + platelet-rich plasma (PRP; RP), repair + BMAC (RB) and repair + PRP + BMAC (RPB). A tear model was created by supraspinatus tendon transection at the footprint. Six weeks after transection, the torn tendon was repaired along with BMAC or PRP administration. Six weeks after repair, shoulder samples were harvested for biomechanical and histological testing. Ten rabbits were used for processing PRP and BMAC, followed by analysis of blood cell composition and the levels of growth factors in vitro. Results The ultimate load-to-failure was significantly higher in RPB group compared to RS group (p = 0.025). BMAC-treated groups showed higher values of biomechanical properties than RS group. The histology of BMAC-treated samples showed better collagen fiber continuity and orientation than RS group. BMAC contained significantly higher levels of the several growth factors than PRP. Conclusions Locally administered BMAC enhanced tendon-to-bone healing and has potential for clinical applications. PMID:29564054

  20. Tendon Transfer Surgery

    Science.gov (United States)

    ... All Topics A-Z Videos Infographics Symptom Picker Anatomy Bones Joints Muscles Nerves Vessels Tendons About Hand Surgery What is ... Hand Therapist? Media Find a Hand Surgeon Home Anatomy ... DESCRIPTION The tendon is the strong cord at either end of a muscle that is attached to bone. Tendons , combined with ...

  1. Anterior-Posterior Instability of the Knee Following ACL Reconstruction with Bone-Patellar Tendon-Bone Ligament in Comparison with Four-Strand Hamstrings Autograft

    Directory of Open Access Journals (Sweden)

    A. G. Angoules

    2013-01-01

    Full Text Available Purpose. To evaluate anterior-posterior knee laxity using two different autografts. Material-Methods. 40 patients, (34 males and 6 women, 17–54 years old (mean: 31, were included in the present study. Group A (4SHS = 20 underwent reconstruction using four-strand hamstrings, and group B (BPBT = 20 underwent reconstruction using bone-patellar tendon-bone autograft. Using the KT-1000 arthrometer, knee instability was calculated in both knees of all patients preoperatively and 3, 6, and 12 months after surgery at the ACL-operated knee. The contralateral healthy knee was used as an internal control group. Results. Anterior-posterior instability using the KT1000 Arthrometer was found to be increased after ACL insufficiency. The recorded laxity improved after arthroscopic ACL reconstruction in both groups. However, statistically significant greater values were detected in the bone-patellar tendon-bone group, which revealed reduction of anteroposterior stability values to an extent, where no statistical significance with the normal values even after 3 months after surgery was observed. Conclusions. Anterior-Posterior instability of the knee improved significantly after arthroscopic ACL reconstruction. The bone-patellar tendon-bone graft provided an obvious greater stability.

  2. The "Parachute" Technique: A Simple and Effective Single-Row Procedure to Achieve an Increased Contact Area Between the Cuff-Tendon and Its Footprint.

    Science.gov (United States)

    Natera, Luis; Consigliere, Paolo; Witney-Lagen, Caroline; Brugera, Juan; Sforza, Giuseppe; Atoun, Ehud; Levy, Ofer

    2017-10-01

    Many techniques of arthroscopic rotator cuff repair have been described. No significant differences in clinical outcomes or rerupture rates have been observed when comparing single-row with double-row methods. Not all single- and double-row repairs are the same. The details of the technique used are crucial. It has been shown that the suture-tendon interface is the weakest point of the reconstruction. Therefore, the biomechanical properties of rotator cuff repairs might be influenced more by the suture configuration than by the number of anchors or by the number of rows involved. Techniques that secure less amount of tendon over a smaller area of the healing zone might be expected to have higher failure rates. The way the sutures of the "parachute technique" are configured represents a quadruple mattress that increases the contact and pressure between the tendon and its footprint and increases the primary load to failure of the repair. We present a simple and effective single-row technique that involves the biomechanical and biological advantages related to the increased contact area and pressure between the cuff and its footprint.

  3. An Artificial Tendon with Durable Muscle Interface

    OpenAIRE

    Melvin, Alan; Litsky, Alan; Mayerson, Joel; Witte, David; Melvin, David; Juncosa-Melvin, Natalia

    2010-01-01

    A coupling mechanism that can permanently fix a forcefully contracting muscle to a bone anchor or any totally inert prosthesis would meet a serious need in orthopaedics. Our group developed the OrthoCoupler™ device to satisfy these demands. The objective of this study was to test OrthoCoupler’s performance in vitro and in vivo in the goat semitendinosus tendon model. For in vitro evaluation, 40 samples were fatigue-tested, cycling at 10 load levels, n=4 each. For in vivo evaluation, the semit...

  4. Effect of single- and double-row rotator cuff repair at the tendon-to-bone interface: preliminary results using an in vivo sheep model.

    Science.gov (United States)

    Baums, M H; Schminke, B; Posmyk, A; Miosge, N; Klinger, H-M; Lakemeier, S

    2015-01-01

    The clinical superiority of the double-row technique is still a subject of controversial debate in rotator cuff repair. We hypothesised that the expression of different collagen types will differ between double-row and single-row rotator cuff repair indicating a faster healing response by the double-row technique. Twenty-four mature female sheep were randomly assembled to two different groups in which a surgically created acute infraspinatus tendon tear was fixed using either a modified single- or double-row repair technique. Shoulder joints from female sheep cadavers of identical age, bone maturity, and weight served as untreated control cluster. Expression of type I, II, and III collagen was observed in the tendon-to-bone junction along with recovering changes in the fibrocartilage zone after immunohistological tissue staining at 1, 2, 3, 6, 12, and 26 weeks postoperatively. Expression of type III collagen remained positive until 6 weeks after surgery in the double-row group, whereas it was detectable for 12 weeks in the single-row group. In both groups, type I collagen expression increased after 12 weeks. Type II collagen expression was increased after 12 weeks in the double-row versus single-row group. Clusters of chondrocytes were only visible between week 6 and 12 in the double-row group. The study demonstrates differences regarding the expression of type I and type III collagen in the tendon-to-bone junction following double-row rotator cuff repair compared to single-row repair. The healing response in this acute repair model is faster in the double-row group during the investigated healing period.

  5. One-stage Pelnac Reconstruction in Full-thickness Skin Defects with Bone or Tendon Exposure

    Directory of Open Access Journals (Sweden)

    Xianghong Lou, MS

    2018-03-01

    Full Text Available Summary:. Dermal regeneration template, such as Integra and Pelnac, was originally designed for treating large area burn injury by inducing regeneration of dermis. To date, it has been widely applied in various acute and chronic wound sites. The present study demonstrated that application of artificial dermis alone induced 1-stage wound healing for wounds with bone or tendon exposure that should usually be repaired by flap surgery. Eight patients who presented with skin defects with bone and/or tendon exposure were treated by 1-stage Pelnac approach. All wounds healed within 20 weeks without skin graft or flap surgery. The wound area was reconstructed by nearly normal skin structure and linear scar. In the case of scalp defect, evidence of hair follicle cell migration and regeneration during healing process was observed. Thereby, the 1-stage Pelnac reconstitution can be considered as a novel method for inducing regrowth of epidermis and hair follicles to cure large full-thickness skin defect with bone and tendon exposure in 1 stage.

  6. An artificial tendon with durable muscle interface.

    Science.gov (United States)

    Melvin, Alan; Litsky, Alan; Mayerson, Joel; Witte, David; Melvin, David; Juncosa-Melvin, Natalia

    2010-02-01

    A coupling mechanism that can permanently fix a forcefully contracting muscle to a bone anchor or any totally inert prosthesis would meet a serious need in orthopaedics. Our group developed the OrthoCoupler device to satisfy these demands. The objective of this study was to test OrthoCoupler's performance in vitro and in vivo in the goat semitendinosus tendon model. For in vitro evaluation, 40 samples were fatigue-tested, cycling at 10 load levels, n = 4 each. For in vivo evaluation, the semitendinosus tendon was removed bilaterally in eight goats. Left sides were reattached with an OrthoCoupler, and right sides were reattached using the Krackow stitch with #5 braided polyester sutures. Specimens were harvested 60 days postsurgery and assigned for biomechanics and histology. Fatigue strength of the devices in vitro was several times the contractile force of the semitendinosus muscle. The in vivo devices were built equivalent to two of the in vitro devices, providing an additional safety factor. In strength testing at necropsy, suture controls pulled out at 120.5 +/- 68.3 N, whereas each OrthoCoupler was still holding after the muscle tore, remotely, at 298 +/- 111.3 N (mean +/- SD) (p < 0.0003). Muscle tear strength was reached with the fiber-muscle composite produced in healing still soundly intact. This technology may be of value for orthopaedic challenges in oncology, revision arthroplasty, tendon transfer, and sports-injury reconstruction. (c) 2009 Orthopaedic Research Society.

  7. Xerogel Interfaced Nanofibers Stimulate Bone Regeneration Through the Activation of Integrin and Bone Morphogenetic Protein Pathways.

    Science.gov (United States)

    Lee, Yoo-Mi; Yun, Hyung-Mun; Lee, Hye-Young; Lim, Hyun-Chang; Lee, Hae-Hyoung; Kim, Hae-Won; Kim, Eun-Cheol

    2017-02-01

    A xerogel was interfaced onto biopolymer nanofibers though a core–shell electrospinning design for bone regeneration. The xerogel-interfaced biopolymer nanofibrous matrix was bioactive and highly hydrophilic, with a significant decrease in the water contact angle. The matrix showed excellent in vitro responses of primary osteoblasts in terms of adhesion, proliferation, and migration. Furthermore, the osteoblastic differentiation of cells, including alkaline phosphatase activity, mineralization, and gene expression, was significantly upregulated by the xerogel interface. In vivo animal tests in a critical-sized calvarial defect confirmed the new bone formation ability of the xerogel-surfaced nanofiber matrices. The underlying signaling mechanisms of the stimulation were implied to be integrin and bone morphogenetic protein (BMP) pathways, as demonstrated by the activation of integrin (α2β1) and downstream signaling molecules (FAK, paxillin, RhoA, MAPK, and NF-κB), as well as the BMPs and the downstream transcription factor Smad1/5/8. Taking these findings together, the xerogel-surfaced biopolymer nanofibers are proposed to be a promising scaffold candidate for bone regeneration.

  8. Investigation of index finger triggering force using a cadaver experiment: Effects of trigger grip span, contact location, and internal tendon force.

    Science.gov (United States)

    Chang, Joonho; Freivalds, Andris; Sharkey, Neil A; Kong, Yong-Ku; Mike Kim, H; Sung, Kiseok; Kim, Dae-Min; Jung, Kihyo

    2017-11-01

    A cadaver study was conducted to investigate the effects of triggering conditions (trigger grip span, contact location, and internal tendon force) on index finger triggering force and the force efficiency of involved tendons. Eight right human cadaveric hands were employed, and a motion simulator was built to secure and control the specimens. Index finger triggering forces were investigated as a function of different internal tendon forces (flexor digitorum profundus + flexor digitorum superficialis = 40, 70, and 100 N), trigger grip spans (40, 50, and 60 mm), and contact locations between the index finger and a trigger. Triggering forces significantly increased when internal tendon forces increased from 40 to 100 N. Also, trigger grip spans and contact locations had significant effects on triggering forces; maximum triggering forces were found at a 50 mm span and the most proximal contact location. The results revealed that only 10-30% of internal tendon forces were converted to their external triggering forces. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Effect of Footprint Preparation on Tendon-to-Bone Healing: A Histologic and Biomechanical Study in a Rat Rotator Cuff Repair Model.

    Science.gov (United States)

    Nakagawa, Haruhiko; Morihara, Toru; Fujiwara, Hiroyoshi; Kabuto, Yukichi; Sukenari, Tsuyoshi; Kida, Yoshikazu; Furukawa, Ryuhei; Arai, Yuji; Matsuda, Ken-Ichi; Kawata, Mitsuhiro; Tanaka, Masaki; Kubo, Toshikazu

    2017-08-01

    To compare the histologic and biomechanical effects of 3 different footprint preparations for repair of tendon-to-bone insertions and to assess the behavior of bone marrow-derived cells in each method of insertion repair. We randomized 81 male Sprague-Dawley rats and green fluorescent protein-bone marrow chimeric rats into 3 groups. In group A, we performed rotator cuff repair after separating the supraspinatus tendon from the greater tuberosity and removing the residual tendon tissue. In group B, we also drilled 3 holes into the footprint. The native fibrocartilage was preserved in groups A and B. In group C, we excavated the footprint until the cancellous bone was exposed. Histologic repair of the tendon-to-bone insertion, behavior of the bone marrow-derived cells, and ultimate force to failure were examined postoperatively. The areas of metachromasia in groups A, B, and C were 0.033 ± 0.019, 0.089 ± 0.022, and 0.002 ± 0.001 mm 2 /mm 2 , respectively, at 4 weeks and 0.029 ± 0.022, 0.090 ± 0.039, and 0.003 ± 0.001 mm 2 /mm 2 , respectively, at 8 weeks. At 4 and 8 weeks postoperatively, significantly higher cartilage matrix production was observed in group B than in group C (4 weeks, P = .002; 8 weeks, P repair tissue and biomechanical strength at the tendon-to-bone insertion after rotator cuff repair in an animal model. Drilling into the footprint and preserving the fibrocartilage can enhance repair of tendon-to-bone insertions. This method may be clinically useful in rotator cuff repair. Copyright © 2017 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  10. Effects of Volar Tilt, Wrist Extension, and Plate Position on Contact Between Flexor Pollicis Longus Tendon and Volar Plate.

    Science.gov (United States)

    Wurtzel, Caroline N Wolfe; Burns, Geoffrey T; Zhu, Andy F; Ozer, Kagan

    2017-12-01

    Volar plates positioned at, or distal to, the watershed line have been shown to have a higher incidence of attritional rupture of the flexor pollicis longus (FPL). In this study, we aimed to evaluate the effect of wrist extension and volar tilt on the contact between the plate and the FPL tendon in a cadaver model. We hypothesized that, following volar plate application, loss of native volar tilt increases the contact between the FPL and the plate at lower degrees of wrist extension. A volar locking plate was applied on 6 fresh-frozen cadavers. To determine the contact between the plate and the FPL tendon, both structures were wrapped with copper wire and circuit conductivity was monitored throughout wrist motion. A lateral wrist radiograph was obtained at each circuit closure, indicating tendon-plate contact. Baseline measurements were obtained with plate positioned at Soong grades 0, 1, and 2. An extra-articular osteotomy was made and contact was recorded at various volar tilt angles (+5°, 0°, -5°, -10°, -15°, and -20°) in 3 different plate positions. A blinded observer measured the degree of wrist extension on all lateral radiographs. Data were analyzed using linear mixed-effects regression model. Plates placed distal to the watershed line had the most contact throughout wrist range of motion. Significantly, less wrist extension was required for contact in wrists with neutral or dorsal tilt and in distally placed volar plates. Volar tilt, wrist extension, and plate position were 3 independent risk factors determining contact between plate and tendon. Loss of volar tilt, increased wrist extension, and higher Soong grade plate position result in greater contact between wire-wrapped FPL tendon and plate. The FPL/plate contact chart generated in this study may be used to assess the risk of rupture in the clinical setting. Copyright © 2017 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  11. Effect of platelet-rich plasma on tendon-to-bone healing after rotator cuff repair in rats: an in vivo experimental study.

    Science.gov (United States)

    Hapa, Onur; Cakıcı, Hüsamettin; Kükner, Aysel; Aygün, Hayati; Sarkalan, Nazlı; Baysal, Gökhan

    2012-01-01

    The purpose of this experimental study was to analyze the effects of local autologous platelet-rich plasma (PRP) injection on tendon-to-bone healing in a rotator cuff repair model in rats. Rotator cuff injury was created in 68 left shoulders of rats. PRP was obtained from the blood of an additional 15 rats. The 68 rats were divided into 4 groups with 17 rats in each group; PRP group (Week 2), control group (Week 2), PRP group (Week 4), and control group (Week 4). Platelet-rich plasma or saline was injected to the repair area intraoperatively. Rats were sacrificed 2 and 4 weeks after the surgery. Histological analysis using a semiquantitative scoring was performed on 7 rats per group. Tendon integrity and increases in vascularity and inflammatory cells and the degree of new bone formation were evaluated and compared between the groups. The remaining tendons (n=10) were mechanically tested. Degree of inflammation and vascularity were less in the study group at both time intervals (protator cuff tendon-to-bone healing and enhance initial tendon-to-bone healing remodeling. This may represent a clinically important improvement in rotator cuff repair.

  12. Development and application of a direct method to observe the implant/bone interface using simulated bone.

    Science.gov (United States)

    Yamaguchi, Yoko; Shiota, Makoto; FuJii, Masaki; Sekiya, Michi; Ozeki, Masahiko

    2016-01-01

    Primary stability after implant placement is essential for osseointegration. It is important to understand the bone/implant interface for analyzing the influence of implant design on primary stability. In this study rigid polyurethane foam is used as artificial bone to evaluate the bone-implant interface and to identify where the torque is being generated during placement. Five implant systems-Straumann-Standard (ST), Straumann-Bone Level (BL), Straumann-Tapered Effect (TE), Nobel Biocare-Brånemark MKIII (MK3), and Nobel Biocare-Brånemark MKIV (MK4)-were used for this experiment. Artificial bone blocks were prepared and the implant was installed. After placement, a metal jig and one side artificial bone block were removed and then the implant embedded in the artificial bone was exposed for observing the bone-implant interface. A digital micro-analyzer was used for observing the contact interface. The insertion torque values were 39.35, 23.78, 12.53, 26.35, and 17.79 N cm for MK4, BL, ST, TE, and MK3, respectively. In ST, MK3, TE, MK4, and BL the white layer areas were 61 × 103 μm(2), 37 × 103 μm(2), 103 × 103 μm(2) in the tapered portion and 84 × 03 μm(2) in the parallel portion, 134 × 103 μm(2), and 98 × 103 μm(2) in the tapered portion and 87 × 103 μm(2) in the parallel portion, respectively. The direct observation method of the implant/artificial bone interface is a simple and useful method that enables the identification of the area where implant retention occurs. A white layer at the site of stress concentration during implant placement was identified and the magnitude of the stress was quantitatively estimated. The site where the highest torque occurred was the area from the thread crest to the thread root and the under and lateral aspect of the platform. The artificial bone debris created by the self-tapping blade accumulated in both the cutting chamber and in the space between the threads and artificial bone.

  13. Mechanoactive scaffold induces tendon remodeling and expression of fibrocartilage markers.

    Science.gov (United States)

    Spalazzi, Jeffrey P; Vyner, Moira C; Jacobs, Matthew T; Moffat, Kristen L; Lu, Helen H

    2008-08-01

    Biological fixation of soft tissue-based grafts for anterior cruciate ligament (ACL) reconstruction poses a major clinical challenge. The ACL integrates with subchondral bone through a fibrocartilage enthesis, which serves to minimize stress concentrations and enables load transfer between two distinct tissue types. Functional integration thus requires the reestablishment of this fibrocartilage interface on reconstructed ACL grafts. We designed and characterized a novel mechanoactive scaffold based on a composite of poly-alpha-hydroxyester nanofibers and sintered microspheres; we then used the scaffold to test the hypothesis that scaffold-induced compression of tendon grafts would result in matrix remodeling and the expression of fibrocartilage interface-related markers. Histology coupled with confocal microscopy and biochemical assays were used to evaluate the effects of scaffold-induced compression on tendon matrix collagen distribution, cellularity, proteoglycan content, and gene expression over a 2-week period. Scaffold contraction resulted in over 15% compression of the patellar tendon graft and upregulated the expression of fibrocartilage-related markers such as Type II collagen, aggrecan, and transforming growth factor-beta3 (TGF-beta3). Additionally, proteoglycan content was higher in the compressed tendon group after 1 day. The data suggest the potential of a mechanoactive scaffold to promote the formation of an anatomic fibrocartilage enthesis on tendon-based ACL reconstruction grafts.

  14. Plasma-sprayed titanium coating to polyetheretherketone improves the bone-implant interface.

    Science.gov (United States)

    Walsh, William R; Bertollo, Nicky; Christou, Chrisopher; Schaffner, Dominik; Mobbs, Ralph J

    2015-05-01

    Rapid and stable fixation at the bone-implant interface would be regarded as one of the primary goals to achieve clinical efficacy, regardless of the surgical site. Although mechanical and physical properties of polyetheretherketone (PEEK) provide advantages for implant devices, the hydrophobic nature and the lack of direct bone contact remains a limitation. To examine the effects of a plasma-sprayed titanium coated PEEK on the mechanical and histologic properties at the bone-implant interface. A preclinical laboratory study. Polyetheretherketone and plasma-sprayed titanium coated PEEK implants (Ti-bond; Spinal Elements, Carlsbad, CA, USA) were placed in a line-to-line manner in cortical bone and in a press-fit manner in cancellous bone of adult sheep using an established ovine model. Shear strength was assessed in the cortical sites at 4 and 12 weeks, whereas histology was performed in cortical and cancellous sites at both time points. The titanium coating dramatically improved the shear strength at the bone-implant interface at 4 weeks and continued to improve with time compared with PEEK. Direct bone ongrowth in cancellous and cortical sites can be achieved using a plasma-sprayed titanium coating on PEEK. Direct bone to implant bonding can be achieved on PEEK in spite of its hydrophobic nature using a plasma-sprayed titanium coating. The plasma-sprayed titanium coating improved mechanical properties in the cortical sites and the histology in cortical and cancellous sites. Copyright © 2015 Elsevier Inc. All rights reserved.

  15. Experimental and numerical study of cemented bone-implant interface behaviour

    Directory of Open Access Journals (Sweden)

    P. Zlamal

    2011-01-01

    Full Text Available Although the total hip replacement (THR is a long-proven method of surgical treatment of diseases and disorders of the human hip, the surgery brings some risk of long-term instability of the joint. The aim of the research was to investigate the cemented bone-implant interface behavior. The main problems (cement layer degradation and bone-cement interface debonding during physiological loading conditions have been investigated using a custom hip simulator. The experimental setup was designed to allow cyclic loading of the sample of pelvic bone with implanted cemented acetabular component. The hip contact force of required direction and magnitude was applied to the implant using a spherical femoral component head. The most unfavorable activity (downstairs walking was simulated. The process of damage accumulation in the fixation was monitored by repeated scanning using high resolution micro Computed Tomography (µCT. Use of micro-focus source and large high-resolution flat panel detector allows investigation of structural changes and crack propagation both in the cement layer and the trabecular bone.

  16. Nanoscale characterization of bone-implant interface and biomechanical modulation of bone ingrowth

    Energy Technology Data Exchange (ETDEWEB)

    Clark, Paul A. [Tissue Engineering Laboratory MC 841, Departments of Anatomy and Cell Biology, Bioengineering, and Orthodontics, University of Illinois at Chicago, Chicago, 801 South Paulina Street, Illinois 60612 (United States)]. E-mail: pclark4@gmail.com; Clark, Andrew M. [Tissue Engineering Laboratory MC 841, Departments of Anatomy and Cell Biology, Bioengineering, and Orthodontics, University of Illinois at Chicago, Chicago, 801 South Paulina Street, Illinois 60612 (United States); Rodriguez, Anthony [Tissue Engineering Laboratory MC 841, Departments of Anatomy and Cell Biology, Bioengineering, and Orthodontics, University of Illinois at Chicago, Chicago, 801 South Paulina Street, Illinois 60612 (United States); Hussain, Mohammad A. [Tissue Engineering Laboratory MC 841, Departments of Anatomy and Cell Biology, Bioengineering, and Orthodontics, University of Illinois at Chicago, Chicago, 801 South Paulina Street, Illinois 60612 (United States); Mao, Jeremy J. [Tissue Engineering Laboratory MC 841, Departments of Anatomy and Cell Biology, Bioengineering, and Orthodontics, University of Illinois at Chicago, Chicago, 801 South Paulina Street, Illinois 60612 (United States)]. E-mail: jmao2@uic.edu

    2007-04-15

    Bone-implant interface is characterized by an array of cells and macromolecules. This study investigated the nanomechancial properties of bone-implant interface using atomic force microscopy in vitro, and the mechanical modulation of implant bone ingrowth in vivo using bone histomorphometry. Upon harvest of screw-type titanium implants placed in vivo in the rabbit maxilla and proximal femur for 4 weeks, nanoindentation was performed in the bone-implant interface at 60-{mu}m intervals radially from the implant surface. The average Young's Moduli (E) of the maxillary bone-implant interface was 1.13 {+-} 0.27 MPa, lacking significant differences at all intervals. In contrast, an increasing gradient of E was observed radially from the femur bone-implant interface: 0.87 {+-} 0.25 MPa to 2.24 {+-} 0.69 MPa, representing significant differences among several 60-{mu}m intervals. In a separate experiment, bone healing was allowed for 6 weeks for proximal femur implants. The right femoral implant received axial cyclic loading at 200 mN and 1 Hz for 10 min/d over 12 days, whereas the left femoral implant served as control. Cyclic loading induced significantly higher bone volume, osteoblast numbers per endocortical bone surface, mineral apposition rate, and bone formation rate than controls. These data demonstrate nanoscale and microscale characterizations of bone-implant interface, and mechanical modulation of bone ingrowth surrounding titanium implants.

  17. Nanoscale characterization of bone-implant interface and biomechanical modulation of bone ingrowth

    International Nuclear Information System (INIS)

    Clark, Paul A.; Clark, Andrew M.; Rodriguez, Anthony; Hussain, Mohammad A.; Mao, Jeremy J.

    2007-01-01

    Bone-implant interface is characterized by an array of cells and macromolecules. This study investigated the nanomechancial properties of bone-implant interface using atomic force microscopy in vitro, and the mechanical modulation of implant bone ingrowth in vivo using bone histomorphometry. Upon harvest of screw-type titanium implants placed in vivo in the rabbit maxilla and proximal femur for 4 weeks, nanoindentation was performed in the bone-implant interface at 60-μm intervals radially from the implant surface. The average Young's Moduli (E) of the maxillary bone-implant interface was 1.13 ± 0.27 MPa, lacking significant differences at all intervals. In contrast, an increasing gradient of E was observed radially from the femur bone-implant interface: 0.87 ± 0.25 MPa to 2.24 ± 0.69 MPa, representing significant differences among several 60-μm intervals. In a separate experiment, bone healing was allowed for 6 weeks for proximal femur implants. The right femoral implant received axial cyclic loading at 200 mN and 1 Hz for 10 min/d over 12 days, whereas the left femoral implant served as control. Cyclic loading induced significantly higher bone volume, osteoblast numbers per endocortical bone surface, mineral apposition rate, and bone formation rate than controls. These data demonstrate nanoscale and microscale characterizations of bone-implant interface, and mechanical modulation of bone ingrowth surrounding titanium implants

  18. Gross and histological evaluation of early lesions of navicular bone and deep digital flexor tendon in horses

    Directory of Open Access Journals (Sweden)

    Komosa Marcin

    2014-03-01

    Full Text Available The study aimed at evaluation of pathological lesions on flexor surface of navicular bone and deep digital flexor tendon in horses graded in standard X-ray examination as 2 (fair. The evaluation was performed on fifteen horses (6-9 years of age. Analysis procedure involved examining navicular bones on X-ray pictures, post-slaughter preparation of navicular bones from the hoof capsule, macroscopic evaluation of fibrocartilage on flexor surface, and analysis of histologic preparations. In horses with navicular bones graded as 2, early pathological changes have already developed, even if such horses were not lame. The pathological changes included fibrillation and disruption of deep digital flexor tendon surface, loss of fibrocartillage in sagittal ridge area of navicular bone, thinning of subchondral bone on its flexor surface, and fibromyxoid changes in chondroid matrix. In terms of clinical relevance, more studies are needed to understand the sequence of changes in a better way.

  19. Functional Attachment of Soft Tissues to Bone: Development, Healing, and Tissue Engineering

    Science.gov (United States)

    Lu, Helen H.; Thomopoulos, Stavros

    2014-01-01

    Connective tissues such as tendons or ligaments attach to bone across a multitissue interface with spatial gradients in composition, structure, and mechanical properties. These gradients minimize stress concentrations and mediate load transfer between the soft and hard tissues. Given the high incidence of tendon and ligament injuries and the lack of integrative solutions for their repair, interface regeneration remains a significant clinical challenge. This review begins with a description of the developmental processes and the resultant structure-function relationships that translate into the functional grading necessary for stress transfer between soft tissue and bone. It then discusses the interface healing response, with a focus on the influence of mechanical loading and the role of cell-cell interactions. The review continues with a description of current efforts in interface tissue engineering, highlighting key strategies for the regeneration of the soft tissue–to-bone interface, and concludes with a summary of challenges and future directions. PMID:23642244

  20. ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION: A COMPARISON BETWEEN BONE PATELLAR TENDON BONE GRAFT AND LIPSCOMB PROCEDURE - A FOLLOWUP STUDY OF 7 YEARS

    Directory of Open Access Journals (Sweden)

    Vijayamohan S

    2016-07-01

    Full Text Available BACKGROUND Anterior Cruciate Ligament injury has become more common and the demand by the patients to return to pre-injury level of activity has made reconstruction of the ligament very crucial. Though there are various techniques in reconstructing the anterior cruciate ligament, in this study, we compare two most commonly used techniques to see whether there is any significant difference in the outcome. METHODS Study included 25 patients in the age group of 19-36 years, of which 23 were males. The patients were divided randomly into 2 groups, and 15 patients underwent Anterior Cruciate Ligament reconstruction using Bone Patellar Tendon Bone Graft and 10 patients had Hamstring graft. RESULTS Patients were followed up at regular intervals monthly for the first six months and then at three monthly intervals. Patients were assessed using Knee Scoring Scale of Lysholm and Gillquist and International Knee Documentation Committee (IKDC scoring system. In addition, activity level, harvest site pain, thigh atrophy, kneeling pain and hamstring pain were assessed. All patients were followed up for a minimum period of 2 years. 20% of both groups were able to return to strenuous activity level, and 67% of Patellar tendon group and 50% of the Hamstring tendon group were able to return to moderate level of activity. 55% of patients in the patellar tendon group and 20% of patients in the hamstring tendon group had donor site pain in the first 6 months. 73% of patients in the hamstring group had at least 10 mm of thigh wasting. Pain on kneeling was seen only in the patellar tendon group (35% while hamstring pain was found only in the hamstring group (20%. CONCLUSIONS Patients in the patellar tendon group had increased anterior stability and were able to return to strenuous occupation. The difference in thigh atrophy between the two groups was not significant. The hamstring group had lower graft harvest site morbidity. Lachman test was the single most accurate

  1. Ultrasound in Total Hip Replacement: Value of Anterior Acetabular Cup Visibility and Contact With the Iliopsoas Tendon.

    Science.gov (United States)

    Guillin, Raphaël; Bertaud, Valérie; Garetier, Marc; Fantino, Olivier; Polard, Jean-Louis; Lambotte, Jean-Christophe

    2018-06-01

    To assess visibility of the acetabular cup in total hip replacement and to determine the value of direct and indirect signs of iliopsoas impingement syndrome with ultrasound. Ultrasound examinations were performed by a single operator in 17 patients with iliopsoas impingement syndrome and 48 control patients. Cup visibility, contact between the cup and psoas tendon, and the presence of indirect signs of iliopsoas impingement syndrome were investigated in all patients. When the acetabular cup was visible, its size and position in relation to the psoas tendon were recorded. Anterior cup visibility (P = .03), contact with the psoas tendon (P cup shift of 3 mm or greater yielded respective sensitivities of 82% and 59% and specificities of 81% and 100%. When iliopsoas impingement syndrome is clinically suspected, the presence of iliopsoas bursitis or a posteroanterior cup shift of greater than 3 mm under the psoas tendon serve to confirm the diagnosis. In the absence of these conditions, a therapeutic test may be necessary because of the incomplete, albeit high, specificity of other signs. © 2017 by the American Institute of Ultrasound in Medicine.

  2. Extensor Tendon Injuries

    Science.gov (United States)

    ... All Topics A-Z Videos Infographics Symptom Picker Anatomy Bones Joints Muscles Nerves Vessels Tendons About Hand Surgery What is a Hand Surgeon? What is a Hand Therapist? Media Find a Hand Surgeon Home Anatomy Extensor Tendon Injuries Email to a friend * required ...

  3. The Effects of Subcrestal Implant Placement on Crestal Bone Levels and Bone-to-Abutment Contact: A Microcomputed Tomographic and Histologic Study in Dogs.

    Science.gov (United States)

    Fetner, Michael; Fetner, Alan; Koutouzis, Theofilos; Clozza, Emanuele; Tovar, Nick; Sarendranath, Alvin; Coelho, Paulo G; Neiva, Kathleen; Janal, Malvin N; Neiva, Rodrigo

    2015-01-01

    Implant design and the implant-abutment interface have been regarded as key influences on crestal bone maintenance over time. The aim of the present study was to determine crestal bone changes around implants placed at different depths in a dog model. Thirty-six two-piece dental implants with a medialized implant-abutment interface and Morse taper connection (Ankylos, Dentsply) were placed in edentulous areas bilaterally in six mongrel dogs. On each side of the mandible, three implants were placed randomly at the bone crest, 1.5 mm subcrestally, or 3.0 mm subcrestally. After 3 months, the final abutments were torqued into place. At 6 months, the animals were sacrificed and samples taken for microcomputed tomographic (micro-CT) and histologic evaluations. Micro-CT analysis revealed similar crestal or marginal bone loss among groups. Both subcrestal implant groups lost significantly less crestal and marginal bone than the equicrestal implants. Bone loss was greatest on the buccal of the implants, regardless of implant placement depth. Histologically, implants placed subcrestally were found to have bone in contact with the final abutment and on the implant platform. Implants with a centralized implant-abutment interface and Morse taper connection can be placed subcrestally without significant loss of crestal or marginal bone. Subcrestal placement of this implant system appears to be advantageous in maintaining bone height coronal to the implant platform.

  4. Morphological experimental study of bone stress at the interface acetabular bone/prosthetic cup in the bipolar hip prosthesis.

    Science.gov (United States)

    Anuşca, D; Pleşea, I E; Iliescu, N; Tomescu, P; Poenaru, F; Dascălu, V; Pop, O T

    2006-01-01

    By calculating the tension and distortion of the elements composing the bipolar prosthesis under extreme conditions encountered in real life using a special post-processing program, we established the variation curves of the contact pressure at the hip bone-cup, armor-cup and cup-femoral head interface. By comparing the data obtained from all the examined cases, important conclusions were drawn regarding the influence of tension and pressure distribution on the structural integrity and biomechanics of the prosthesis, as well as the acetabular wear and tear, in order to assess its reliability. The experimentally determined tension and distortion status at the acetabular bone-metal armour interface, lead to the wear and tear phenomenon, which can be explained by three mechanisms and theories incompletely reflecting the overall process. The histopathologic study of the acetabular bone tissue using FEM (finite elements method) on surgically removed specimens will probably lead to the identification of a series of factors that could reduce the rate of the wear and tear process.

  5. Piezoelectricity and absorption of water in biomaterials: bone and tendon

    International Nuclear Information System (INIS)

    Ghilardi Netto, T.

    1973-01-01

    A new application of the Fabry-Perot interferometer has been developed, capable of measuring variations in length with a precision of the order of one angstrom. The method has been applied to the determination of some of the inverse piezoelectric coefficients of bovine bone and tendon. The effect of water in these materials was carefully measured and shown to decrease the piezoelectricity. Correlations between the piezoelectricity and length, weight, and volume and surface resistivity were made during the absorption of water [pt

  6. The Masticatory Contractile Load Induced Expression and Activation of Akt1/PKBα in Muscle Fibers at the Myotendinous Junction within Muscle-Tendon-Bone Unit

    Directory of Open Access Journals (Sweden)

    Yüksel Korkmaz

    2010-01-01

    Full Text Available The cell specific detection of enzyme activation in response to the physiological contractile load within muscle-tendon-bone unit is essential for understanding of the mechanical forces transmission from muscle cells via tendon to the bone. The hypothesis that the physiological mechanical loading regulates activation of Akt1/PKBα at Thr308 and at Ser473 in muscle fibers within muscle-tendon-bone unit was tested using quantitative immunohistochemistry, confocal double fluorescence analysis, and immunoblot analysis. In comparison to the staining intensities in peripheral regions of the muscle fibers, Akt1/PKBα was detected with a higher staining intensity in muscle fibers at the myotendinous junction (MTJ areas. In muscle fibers at the MTJ areas, Akt1/PKBα is dually phosphorylated at Thr308 and Ser473. The immunohistochemical results were confirmed by immunoblot analysis. We conclude that contractile load generated by masticatory muscles induces local domain-dependent expression of Akt1/PKBα as well as activation by dually phosphorylation at Thr308 and Ser473 in muscle fibers at the MTJ areas within muscle-tendon-bone unit.

  7. Full-Thickness Skin Grafting with De-Epithelization of the Wound Margin for Finger Defects with Bone or Tendon Exposure

    Directory of Open Access Journals (Sweden)

    Jun Hee Lee

    2015-05-01

    Full Text Available BackgroundFull-thickness skin grafts (FTSGs are generally considered unreliable for coverage of full-thickness finger defects with bone or tendon exposure, and there are few clinical reports of its use in this context. However, animal studies have shown that an FTSG can survive over an avascular area ranging up to 12 mm in diameter. In our experience, the width of the exposed bones or tendons in full-thickness finger defects is <7 mm. Therefore, we covered the bone- or tendon-exposed defects of 16 fingers of 10 patients with FTSGs.MethodsThe surgical objectives were healthy granulation tissue formation in the wound bed, marginal de-epithelization of the normal skin surrounding the defect, preservation of the subdermal plexus of the central graft, and partial excision of the dermis along the graft margin. The donor site was the mastoid for small defects and the groin for large defects.ResultsMost of the grafts (15 of 16 fingers survived without significant surgical complications and achieved satisfactory functional and aesthetic results. Minor complications included partial graft loss in one patient, a minimal extension deformity in two patients, a depression deformity in one patient, and mild hyperpigmentation in four patients.ConclusionsWe observed excellent graft survival with this method with no additional surgical injury of the normal finger, satisfactory functional and aesthetic outcomes, and no need for secondary debulking procedures. Potential disadvantages include an insufficient volume of soft tissue and graft hyperpigmentation. Therefore, FTSGs may be an option for treatment of full-thickness finger defects with bone or tendon exposure.

  8. Quadriceps tendon autograft for arthroscopic knee ligament reconstruction: use it now, use it often.

    Science.gov (United States)

    Sheean, Andrew J; Musahl, Volker; Slone, Harris S; Xerogeanes, John W; Milinkovic, Danko; Fink, Christian; Hoser, Christian

    2018-04-28

    Traditional bone-patellar tendon-bone and hamstring tendon ACL grafts are not without limitations. A growing body of anatomic, biomechanical and clinical data has demonstrated the utility of quadriceps tendon autograft in arthroscopic knee ligament reconstruction. The quadriceps tendon autograft provides a robust volume of tissue that can be reliably harvested, mitigating the likelihood of variably sized grafts and obviating the necessity of allograft augmentation. Modern, minimally invasive harvest techniques offer the advantages of low rates of donor site morbidity and residual extensor mechanism strength deficits. New data suggest that quadriceps tendon autograft may possess superior biomechanical characteristics when compared with bone-patella tendon-bone (BPTB) autograft. However, there have been very few direct, prospective comparisons between the clinical outcomes associated with quadriceps tendon autograft and other autograft options (eg, hamstring tendon and bone-patellar tendon-bone). Nevertheless, quadriceps tendon autograft should be one of the primary options in any knee surgeon's armamentarium. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  9. Knitted poly-lactide-co-glycolide scaffold loaded with bone marrow stromal cells in repair and regeneration of rabbit Achilles tendon.

    Science.gov (United States)

    Ouyang, Hong Wei; Goh, James C H; Thambyah, Ashvin; Teoh, Swee Hin; Lee, Eng Hin

    2003-06-01

    The objectives of this study were to evaluate the morphology and biomechanical function of Achilles tendons regenerated using knitted poly-lactide-co-glycolide (PLGA) loaded with bone marrow stromal cells (bMSCs). The animal model used was that of an adult female New Zealand White rabbit with a 10-mm gap defect of the Achilles tendon. In group I, 19 hind legs with the created defects were treated with allogeneic bMSCs seeded on knitted PLGA scaffold. In group II, the Achilles tendon defects in 19 hind legs were repaired using the knitted PLGA scaffold alone, and in group III, 6 hind legs were used as normal control. The tendon-implant constructs of groups I and II were evaluated postoperatively at 2, 4, 8, and 12 weeks using macroscopic, histological, and immunohistochemical techniques. In addition, specimens from group I (n = 7), group II (n = 7), and group III (n = 6) were harvested for biomechanical test 12 weeks after surgery. Postoperatively, at 2 and 4 weeks, the histology of group I specimens exhibited a higher rate of tissue formation and remodeling as compared with group II, whereas at 8 and 12 weeks postoperation, the histology of both group I and group II was similar to that of native tendon tissue. The wound sites of group I healed well and there was no apparent lymphocyte infiltration. Immunohistochemical analysis showed that the regenerated tendons were composed of collagen types I and type III fibers. The tensile stiffness and modulus of group I were 87 and 62.6% of normal tendon, respectively, whereas those of group II were about 56.4 and 52.9% of normal tendon, respectively. These results suggest that the knitted PLGA biodegradable scaffold loaded with allogeneic bone marrow stromal cells has the potential to regenerate and repair gap defect of Achilles tendon and to effectively restore structure and function.

  10. Discrimination between biological interfaces and crystal-packing contacts

    Directory of Open Access Journals (Sweden)

    Yuko Tsuchiya

    2008-11-01

    Full Text Available Yuko Tsuchiya1, Haruki Nakamura2, Kengo Kinoshita1,31Institute of Medical Science, The University of Tokyo, 4-6-1 Shirokanedai, Minatoku, Tokyo, 108-8639, Japan; 2Institute for Protein Research, Osaka University, 3-2 Yamadaoka, Suita, Osaka, 565-0871, Japan; 3Bioinformatics Research and Development, JST, 4-1-8 Honcho, Kawaguchi, Saitama, 332-0012, JapanAbstract: A discrimination method between biologically relevant interfaces and artificial crystal-packing contacts in crystal structures was constructed. The method evaluates protein-protein interfaces in terms of complementarities for hydrophobicity, electrostatic potential and shape on the protein surfaces, and chooses the most probable biological interfaces among all possible contacts in the crystal. The method uses a discriminator named as “COMP”, which is a linear combination of the complementarities for the above three surface features and does not correlate with the contact area. The discrimination of homo-dimer interfaces from symmetry-related crystal-packing contacts based on the COMP value achieved the modest success rate. Subsequent detailed review of the discrimination results raised the success rate to about 88.8%. In addition, our discrimination method yielded some clues for understanding the interaction patterns in several examples in the PDB. Thus, the COMP discriminator can also be used as an indicator of the “biological-ness” of protein-protein interfaces.Keywords: protein-protein interaction, complementarity analysis, homo-dimer interface, crystal-packing contact, biological interfaces

  11. Biomechanical comparison of expanded polytetrafluoroethylene (ePTFE) and PTFE interpositional patches and direct tendon-to-bone repair for massive rotator cuff tears in an ovine model.

    Science.gov (United States)

    McKeown, Andrew Dj; Beattie, Rebekah F; Murrell, George Ac; Lam, Patrick H

    2016-01-01

    Massive irreparable rotator cuff tears are a difficult problem. Modalities such as irrigation and debridement, partial repair, tendon transfer and grafts have been utilized with high failure rates and mixed results. Synthetic interpositional patch repairs are a novel and increasingly used approach. The present study aimed to examine the biomechanical properties of common synthetic materials for interpositional repairs in contrast to native tendon. Six ovine tendons, six polytetrafluoroethylene (PTFE) felt sections and six expanded PTFE (ePTFE) patch sections were pulled-to-failure to analyze their biomechanical and material properties. Six direct tendon-to-bone surgical method repairs, six interpositional PTFE felt patch repairs and six interpositional ePTFE patch repairs were also constructed in ovine shoulders and pulled-to-failure to examine the biomechanical properties of each repair construct. Ovine tendon had higher load-to-failure (591 N) and had greater stiffness (108 N/mm) than either PTFE felt (296 N, 28 N/mm) or ePTFE patch sections (323 N, 34 N/mm). Both PTFE felt and ePTFE repair techniques required greater load-to-failure (225 N and 177 N, respectively) than direct tendon-to-bone surgical repairs (147 N) in ovine models. Synthetic materials lacked several biomechanical properties, including strength and stiffness, compared to ovine tendon. Interpositional surgical repair models with these materials were significantly stronger than direct tendon-to-bone model repairs.

  12. A systematic review of the concept and clinical applications of bone marrow aspirate concentrate in tendon pathology

    Directory of Open Access Journals (Sweden)

    Imam Mohamed A.

    2017-01-01

    Full Text Available Tendon pathologies are a group of musculoskeletal conditions frequently seen in clinical practice. They can be broadly classified into traumatic, degenerative and overuse-related tendinopathies. Rotator cuff tears, Achilles tendinopathy and tennis elbow are common examples of these conditions. Conventional treatments have shown inconsistent outcomes and might fail to provide satisfactory clinical improvement. With the growing trend towards the use of mesenchymal stem cells (MSCs in other branches of medicine, there is an increasing interest in treating tendon pathologies using the bone marrow MSC. In this article, we provide a systematic literature review documenting the current status of the use of bone marrow aspirate concentrate (BMAC for the treatment of tendon pathologies. We also asked the question on the safety of BMAC and whether there are potential complications associated with BMAC therapy. Our hypothesis is that the use of BMAC provides safe clinical benefit when used for the treatment of tendinopathy or as a biological augmentation of tendon repair. We followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA checklist while preparing this systematic review. A literature search was carried out including the online databases of PubMed, EMBASE, ClinicalTrial.gov and the Cochrane Library from 1960 to the end of May 2015. Relevant studies were selected and critically appraised. Data from eligible studies were extracted and classified per type of tendon pathology. We included 37 articles discussing the application and use of BMAC for the treatment of tendon pathologies. The Critical Appraisal Skills Program (CASP appraisal confirmed a satisfactory standard of 37 studies. Studies were sub-categorised into: techniques of extraction, processing and microscopic examination of BMAC (n = 18, where five studies looked at the evaluation of aspiration techniques (n = 5, augmentation of rotator cuff tears (n = 5

  13. Biomechanical and immunohistochemical analysis of high hydrostatic pressure-treated Achilles tendons

    International Nuclear Information System (INIS)

    Diehl, P.; Steinhauser, E.; Gollwitzer, H.; Heister, C.; Schauwecker, J.; Schmitt, M.; Milz, S.; Mittelmeier, W.

    2006-01-01

    Reconstruction of bone defects caused by malignant tumors is carried out in different ways. At present, tumor-bearing bone segments are devitalized mainly by extracorporeal irradiation or autoclaving, but both methods have substantial disadvantages. In this regard, high hydrostatic pressure (HHP) treatment of the bone is a new, advancing technology that has been used in preclinical testing to inactivate normal cells and tumor cells without altering the biomechanical properties of the bone. The aim of this study was to examine the biomechanical and immunohistochemical properties of tendons after exposure to HHP and to evaluate whether preservation of the bony attachment of tendons and ligaments is possible. For this, 19 paired Achilles tendons were harvested from both hindlimbs of 4-month-old pigs. After preparation, the cross-sectional area of each tendon was determined by magnetic resonance imaging (MRI). For each animal, one of the two tendons was taken at random and exposed to a pressure of 300 MPa (n=9) or 600 MPa (n=10). The contralateral tendon served as an untreated control. The biomechanical properties of the tendons remained unchanged with respect to the tested parameters: Young's modulus (MPa) and tensile strength (MPa). This finding is in line with immunohistochemical labeling results, as no difference in the labeling pattern of collagen I and versican was observed when comparing the HHP group (at 600 MPa) to the untreated control group. We anticipate that during orthopedic surgery HHP can serve as a novel, promising methodical approach to inactivate Achilles tendon and bone cells without altering the biomechanical properties of the tendons. This should allow one to preserve the attachment of tendon and ligaments to the devitalized bone and to facilitate functional reconstruction. (author)

  14. Footprint Contact Area and Interface Pressure Comparison Between the Knotless and Knot-Tying Transosseous-Equivalent Technique for Rotator Cuff Repair.

    Science.gov (United States)

    Kim, Sung-Jae; Kim, Sung-Hwan; Moon, Hyun-Soo; Chun, Yong-Min

    2016-01-01

    To quantify and compare the footprint contact area and interface pressure on the greater tuberosity between knotless and knot-tying transosseous-equivalent (TOE) repair using pressure-sensitive film. We used 11 pairs of fresh-frozen cadaveric shoulders (22 specimens), in which rotator cuff tears were created before repair. Each pair was randomized to either conventional medial knot-tying TOE repair (group A) or medial knotless TOE repair using the modified Mason-Allen technique (group B). Pressure-sensitive film was used to quantify the pressurized contact area and interface pressure between the greater tuberosity and supraspinatus tendon. The mean pressurized contact area was 33.2 ± 2.5 mm(2) for group A and 28.4 ± 2.4 mm(2) for group B. There was a significant difference between groups (P = .005). Although the overall contact configuration of both groups was similar and showed an M shape, group A showed a greater pressurized configuration around the medial row. The mean interface pressure was 0.20 ± 0.02 MPa for group A and 0.17 ± 0.02 MPa for group B. There was a significant difference between groups (P = .001). Contrary to our hypothesis, in this time-zero study, medial knotless TOE repair using a modified Mason-Allen suture produced a significantly inferior footprint contact area and interface pressure compared with conventional medial knot-tying TOE repair. Even though we found a statistically significant difference between the 2 repair methods, it is still unknown if this statistical difference seen in our study has any clinical and radiologic significance. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  15. Heparin functionalization increases retention of TGF-β2 and GDF5 on biphasic silk fibroin scaffolds for tendon/ligament-to-bone tissue engineering.

    Science.gov (United States)

    Font Tellado, Sònia; Chiera, Silvia; Bonani, Walter; Poh, Patrina S P; Migliaresi, Claudio; Motta, Antonella; Balmayor, Elizabeth R; van Griensven, Martijn

    2018-05-01

    The tendon/ligament-to-bone transition (enthesis) is a highly specialized interphase tissue with structural gradients of extracellular matrix composition, collagen molecule alignment and mineralization. These structural features are essential for enthesis function, but are often not regenerated after injury. Tissue engineering is a promising strategy for enthesis repair. Engineering of complex tissue interphases such as the enthesis is likely to require a combination of biophysical, biological and chemical cues to achieve functional tissue regeneration. In this study, we cultured human primary adipose-derived mesenchymal stem cells (AdMCs) on biphasic silk fibroin scaffolds with integrated anisotropic (tendon/ligament-like) and isotropic (bone/cartilage like) pore alignment. We functionalized those scaffolds with heparin and explored their ability to deliver transforming growth factor β2 (TGF-β2) and growth/differentiation factor 5 (GDF5). Heparin functionalization increased the amount of TGF-β2 and GDF5 remaining attached to the scaffold matrix and resulted in biological effects at low growth factor doses. We analyzed the combined impact of pore alignment and growth factors on AdMSCs. TGF-β2 and pore anisotropy synergistically increased the expression of tendon/ligament markers and collagen I protein content. In addition, the combined delivery of TGF-β2 and GDF5 enhanced the expression of cartilage markers and collagen II protein content on substrates with isotropic porosity, whereas enthesis markers were enhanced in areas of mixed anisotropic/isotropic porosity. Altogether, the data obtained in this study improves current understanding on the combined effects of biological and structural cues on stem cell fate and presents a promising strategy for tendon/ligament-to-bone regeneration. Regeneration of the tendon/ligament-to-bone interphase (enthesis) is of significance in the repair of ruptured tendons/ligaments to bone to improve implant integration and

  16. Ultrasound elastography assessment of bone/soft tissue interface

    International Nuclear Information System (INIS)

    Parmar, Biren J; Yang, Xu; Chaudhry, Anuj; Shajudeen, Peer Shafeeq; Nair, Sanjay P; Righetti, Raffaella; Weiner, Bradley K; Tasciotti, Ennio; Krouskop, Thomas A

    2016-01-01

    We report on the use of elastographic imaging techniques to assess the bone/soft tissue interface, a region that has not been previously investigated but may provide important information about fracture and bone healing. The performance of axial strain elastograms and axial shear strain elastograms at the bone/soft tissue interface was studied ex vivo on intact and fractured canine and ovine tibias. Selected ex vivo results were corroborated on intact sheep tibias in vivo. The elastography results were statistically analyzed using elastographic image quality tools. The results of this study demonstrate distinct patterns in the distribution of the normalized local axial strains and axial shear strains at the bone/soft tissue interface with respect to the background soft tissue. They also show that the relative strength and distribution of the elastographic parameters change in the presence of a fracture and depend on the degree of misalignment between the fracture fragments. Thus, elastographic imaging modalities might be used in the future to obtain information regarding the integrity of bones and to assess the severity of fractures, alignment of bone fragments as well as to follow bone healing. (paper)

  17. Ultrasound elastography assessment of bone/soft tissue interface

    Science.gov (United States)

    Parmar, Biren J.; Yang, Xu; Chaudhry, Anuj; Shafeeq Shajudeen, Peer; Nair, Sanjay P.; Weiner, Bradley K.; Tasciotti, Ennio; Krouskop, Thomas A.; Righetti, Raffaella

    2016-01-01

    We report on the use of elastographic imaging techniques to assess the bone/soft tissue interface, a region that has not been previously investigated but may provide important information about fracture and bone healing. The performance of axial strain elastograms and axial shear strain elastograms at the bone/soft tissue interface was studied ex vivo on intact and fractured canine and ovine tibias. Selected ex vivo results were corroborated on intact sheep tibias in vivo. The elastography results were statistically analyzed using elastographic image quality tools. The results of this study demonstrate distinct patterns in the distribution of the normalized local axial strains and axial shear strains at the bone/soft tissue interface with respect to the background soft tissue. They also show that the relative strength and distribution of the elastographic parameters change in the presence of a fracture and depend on the degree of misalignment between the fracture fragments. Thus, elastographic imaging modalities might be used in the future to obtain information regarding the integrity of bones and to assess the severity of fractures, alignment of bone fragments as well as to follow bone healing.

  18. Micro-CT evaluation and histological analysis of screw-bone interface of expansive pedicle screw in osteoporotic sheep.

    Science.gov (United States)

    Wan, Shi-yong; Lei, Wei; Wu, Zi-xiang; Lv, Rong; Wang, Jun; Fu, Suo-chao; Li, Bo; Zhan, Ce

    2008-04-01

    To investigate the properties of screw-bone interface of expansive pedicle screw (EPS) in osteoporotic sheep by micro-CT and histological observation. Six female sheep with bilateral ovariectomy-induced osteoporosis were employed in this experiment. After EPS insertion in each femoral condyle, the sheep were randomly divided into two groups: 3 sheep were bred for 3 months (Group A), while the other 3 were bred for 6 months (Group B). After the animals being killed, the femoral condyles with EPS were obtained, which were three-dimensionally-imaged and reconstructed by micro-CT. Histological evaluation was made thereafter. The trabecular microstructure was denser at the screw-bone interface than in the distant parts in expansive section, especially within the spiral marking. In the non-expansive section, however, there was no significant difference between the interface and the distant parts. The regions of interest (ROI) adjacent to EPS were reconstructed and analyzed by micro-CT with the same thresholds. The three-dimensional (3-D) parameters, including tissue mineral density (TMD), bone volume fraction (BVF, BV/TV), bone surface/bone volume (BS/BV) ratio, trabecular thickness (Tb.Th), and trabecular separation (Tb.Sp), were significantly better in expansive sections than non-expansive sections (P less than 0.05). Histologically, newly-formed bony trabeculae crawled along the expansive fissures and into the center of EPS. The newly-formed bones, as well as the bones at the bone-screw interface, closely contacted with the EPS and constructed four compartments. The findings of the current study, based on micro-CT and histological evaluation, suggest that EPS can significantly provide stabilization in osteoporotic cancellous bones.

  19. Adaptive contact elements for three-dimensional fluid-structure interfaces

    International Nuclear Information System (INIS)

    Kulak, R.F.

    1985-01-01

    A finite element method is developed for treating the mechanics of contact between two deformable bodies which occurs, for example, at fluid-structure interfaces. The method uses a family of adaptive contact elements, which are based upon the penalty method, to handle all of the possible contact configurations that can occur between the discretized contacting bodies. The contact element's nodal connectivity is allowed to change during the computations in order to accommodate finite sliding. The infusion of these elements in the interface results in satisfying the force equilibrium condition during contact. The methodology has been implemented into the NEPTUNE code. Results are presented for an illustrative problem

  20. Adaptive contact elements for three-dimensional fluid-structure interfaces

    Energy Technology Data Exchange (ETDEWEB)

    Kulak, R.F.

    1985-01-01

    A finite element method is developed for treating the mechanics of contact between two deformable bodies which occurs, for example, at fluid-structure interfaces. The method uses a family of adaptive contact elements, which are based upon the penalty method, to handle all of the possible contact configurations that can occur between the discretized contacting bodies. The contact element's nodal connectivity is allowed to change during the computations in order to accommodate finite sliding. The infusion of these elements in the interface results in satisfying the force equilibrium condition during contact. The methodology has been implemented into the NEPTUNE code. Results are presented for an illustrative problem.

  1. Specialisation of extracellular matrix for function in tendons and ligaments

    Science.gov (United States)

    Birch, Helen L.; Thorpe, Chavaunne T.; Rumian, Adam P.

    2013-01-01

    Summary Tendons and ligaments are similar structures in terms of their composition, organisation and mechanical properties. The distinction between them stems from their anatomical location; tendons form a link between muscle and bone while ligaments link bones to bones. A range of overlapping functions can be assigned to tendon and ligaments and each structure has specific mechanical properties which appear to be suited for particular in vivo function. The extracellular matrix in tendon and ligament varies in accordance with function, providing appropriate mechanical properties. The most useful framework in which to consider extracellular matrix differences therefore is that of function rather than anatomical location. In this review we discuss what is known about the relationship between functional requirements, structural properties from molecular to gross level, cellular gene expression and matrix turnover. The relevance of this information is considered by reviewing clinical aspects of tendon and ligament repair and reconstructive procedures. PMID:23885341

  2. Contact angle distribution of particles at fluid interfaces.

    Science.gov (United States)

    Snoeyink, Craig; Barman, Sourav; Christopher, Gordon F

    2015-01-27

    Recent measurements have implied a distribution of interfacially adsorbed particles' contact angles; however, it has been impossible to measure statistically significant numbers for these contact angles noninvasively in situ. Using a new microscopy method that allows nanometer-scale resolution of particle's 3D positions on an interface, we have measured the contact angles for thousands of latex particles at an oil/water interface. Furthermore, these measurements are dynamic, allowing the observation of the particle contact angle with high temporal resolution, resulting in hundreds of thousands of individual contact angle measurements. The contact angle has been found to fit a normal distribution with a standard deviation of 19.3°, which is much larger than previously recorded. Furthermore, the technique used allows the effect of measurement error, constrained interfacial diffusion, and particle property variation on the contact angle distribution to be individually evaluated. Because of the ability to measure the contact angle noninvasively, the results provide previously unobtainable, unique data on the dynamics and distribution of the adsorbed particles' contact angle.

  3. Interface mechanics and histomorphometric analysis of hydroxyapatite-coated and porous glass-ceramic implants in canine bone

    DEFF Research Database (Denmark)

    Nimb, L; Jensen, J S; Gotfredsen, K

    1995-01-01

    A canine study was performed to make a histological and biomechanical evaluation of the interface between bone and two different bioceramic implants. A newly developed glass-ceramic formed by P2O5, CaO, SiO2, and Al2O3, giving a crystal phase composed of CaP2O6-AlPO4-SiP2O7, was compared...... analysis. The ultimate shear strength for the HA-coated implants was significantly higher than in the glass-ceramic group. When these values were related to the histomorphometric measurements, the difference could be explained by the tissue-to-implant contact. The glass-ceramic showed direct contact only...... with nonmineralized, osteoid bone. The HA-coated implants, however, were integrated into the bone. The study indicated that porous glass-ceramic containing AlPO4 causes local osteomalacia and might not be suitable for clinical purposes....

  4. Pullout strength of bone-patellar tendon-bone allograft bone plugs: a comparison of cadaver tibia and rigid polyurethane foam.

    Science.gov (United States)

    Barber, F Alan

    2013-09-01

    To compare the load-to-failure pullout strength of bone-patellar tendon-bone (BPTB) allografts in human cadaver tibias and rigid polyurethane foam blocks. Twenty BPTB allografts were trimmed creating 25 mm × 10 mm × 10 mm tibial plugs. Ten-millimeter tunnels were drilled in 10 human cadaver tibias and 10 rigid polyurethane foam blocks. The BPTB anterior cruciate ligament allografts were inserted into these tunnels and secured with metal interference screws, with placement of 10 of each type in each material. After preloading (10 N), cyclic loading (500 cycles, 10 to 150 N at 200 mm/min) and load-to-failure testing (200 mm/min) were performed. The endpoints were ultimate failure load, cyclic loading elongation, and failure mode. No difference in ultimate failure load existed between grafts inserted into rigid polyurethane foam blocks (705 N) and those in cadaver tibias (669 N) (P = .69). The mean rigid polyurethane foam block elongation (0.211 mm) was less than that in tibial bone (0.470 mm) (P = .038), with a smaller standard deviation (0.07 mm for foam) than tibial bone (0.34 mm). All BPTB grafts successfully completed 500 cycles. The rigid polyurethane foam block showed less variation in test results than human cadaver tibias. Rigid polyurethane foam blocks provide an acceptable substitute for human cadaver bone tibia for biomechanical testing of BPTB allografts and offer near-equivalent results. Copyright © 2013 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  5. Temperature dependence of contact resistance at metal/MWNT interface

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sang-Eui; Moon, Kyoung-Seok; Sohn, Yoonchul, E-mail: yoonchul.son@samsung.com [Materials Research Center, Samsung Advanced Institute of Technology, Samsung Electronics, Suwon 443-803 (Korea, Republic of)

    2016-07-11

    Although contact resistance of carbon nanotube (CNT) is one of the most important factors for practical application of electronic devices, a study regarding temperature dependence on contact resistance of CNTs with metal electrodes has not been found. Here, we report an investigation of contact resistance at multiwalled nanotube (MWNT)/Ag interface as a function of temperature, using MWNT/polydimethylsiloxane (PDMS) composite. Electrical resistance of MWNT/PDMS composite revealed negative temperature coefficient (NTC). Excluding the contact resistance with Ag electrode, the NTC effect became less pronounced, showing lower intrinsic resistivity with the activation energy of 0.019 eV. Activation energy of the contact resistance of MWNT/Ag interface was determined to be 0.04 eV, two times larger than that of MWNT-MWNT network. The increase in the thermal fluctuation assisted electron tunneling is attributed to conductivity enhancement at both MWNT/MWNT and MWNT/Ag interfaces with increasing temperature.

  6. An advanced glycation endproduct (AGE)-rich diet promotes accumulation of AGEs in Achilles tendon

    DEFF Research Database (Denmark)

    Skovgaard, Dorthe; Svensson, Rene B; Scheijen, Jean

    2017-01-01

    Advanced Glycation Endproducts (AGEs) accumulate in long-lived tissue proteins like collagen in bone and tendon causing modification of the biomechanical properties. This has been hypothesized to raise the risk of orthopedic injury such as bone fractures and tendon ruptures. We evaluated the rela......Advanced Glycation Endproducts (AGEs) accumulate in long-lived tissue proteins like collagen in bone and tendon causing modification of the biomechanical properties. This has been hypothesized to raise the risk of orthopedic injury such as bone fractures and tendon ruptures. We evaluated...... the relationship between AGE content in the diet and accumulation of AGEs in weight-bearing animal Achilles tendon. Two groups of mice (C57BL/6Ntac) were fed with either high-fat diet low in AGEs high-fat diet (HFD) (n = 14) or normal diet high in AGEs (ND) (n = 11). AGE content in ND was six to 50-fold higher...... than HFD The mice were sacrificed at week 40 and Achilles and tail tendons were carefully excised to compare weight and nonweight-bearing tendons. The amount of the AGEs carboxymethyllysine (CML), methylglyoxal-derived hydroimidazolone (MG-H1) and carboxyethyllysine (CEL) in Achilles and tail tendon...

  7. Biomimetic approaches with smart interfaces for bone regeneration.

    Science.gov (United States)

    Sailaja, G S; Ramesh, P; Vellappally, Sajith; Anil, Sukumaran; Varma, H K

    2016-11-05

    A 'smart tissue interface' is a host tissue-biomaterial interface capable of triggering favourable biochemical events inspired by stimuli responsive mechanisms. In other words, biomaterial surface is instrumental in dictating the interface functionality. This review aims to investigate the fundamental and favourable requirements of a 'smart tissue interface' that can positively influence the degree of healing and promote bone tissue regeneration. A biomaterial surface when interacts synergistically with the dynamic extracellular matrix, the healing process become accelerated through development of a smart interface. The interface functionality relies equally on bound functional groups and conjugated molecules belonging to the biomaterial and the biological milieu it interacts with. The essential conditions for such a special biomimetic environment are discussed. We highlight the impending prospects of smart interfaces and trying to relate the design approaches as well as critical factors that determine species-specific functionality with special reference to bone tissue regeneration.

  8. Achilles Tendon Rupture

    Science.gov (United States)

    ... is a strong fibrous cord that connects the muscles in the back of your calf to your heel bone. If you overstretch your Achilles tendon, it can tear (rupture) completely or just partially. If your Achilles ...

  9. Mechanical alterations of rabbit Achilles' tendon after immobilization correlate with bone mineral density but not with magnetic resonance or ultrasound imaging.

    Science.gov (United States)

    Trudel, Guy; Koike, Yoichi; Ramachandran, Nanthan; Doherty, Geoff; Dinh, Laurent; Lecompte, Martin; Uhthoff, Hans K

    2007-12-01

    To assess the usefulness of magnetic resonance imaging (MRI), ultrasound (US) imaging, or bone mineral density (BMD) in predicting the mechanical properties of immobilized rabbit Achilles' tendons. Experimental study. Basic university laboratory. Twenty-eight rabbits. Twelve rabbits had 1 hindlimb casted for 4 weeks and 10 rabbits were casted for 8 weeks. Contralateral legs and 12 normal hindlimbs served as controls. Achilles' tendon dimensions on MRI and US, T1- and T2-signal intensities on MRI, classification of abnormalities on MRI and US; BMD of the calcaneus with dual-energy x-ray absorptiometry. Biomechanic measures consisted of peak load, stiffness, and stress. Imaging variables were correlated with biomechanic alterations. Immobilized Achilles' tendons were weaker and showed decreased mechanical stress compared with their contralateral legs and controls (all PAchilles' tendons after immobilization. However, neither increased MRI nor US signal abnormality was found. BMD was lower in immobilized calcanei and larger in contralateral legs than controls. Only BMD correlated with both the decreased peak load (R2=.42, PAchilles' tendon. This study established weakened mechanical properties of immobilized Achilles' tendons. BMD of the calcaneus, but not MRI and US, was predictive of the mechanical alterations in immobilized Achilles' tendons. BMD may be a useful biomarker to monitor disease and recovery in Achilles' tendons.

  10. COMPARATIVE STUDY OF CLINICAL OUTCOME OF ARTHROSCOPIC ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION BONE PATELLAR TENDON BONE GRAFT V/S HAMSTRING GRAFT

    Directory of Open Access Journals (Sweden)

    Priyank

    2015-08-01

    fulfilling the predetermined inclusion and exclusion criteria were included in the study. STATISTICAL METHODS : Intergroup comparison was analysed by K - Independent sample t test. Intragroup comparison was analysed by Paired t - test. RESULTS : Patients were divided into two groups and treated with using Bone - patellar tendon - bone graft and Hamstring graft respectively. Mean age group of patients was 29.16 yrs. (range 16 - 51yrs and 30.88 yrs. (range 19 - 48yrs in group A and B respectively we found the incidence of ACL injury in 15 - 44 years age group to be greater than twice the general population. A mean delay in surgery of 4.66 months (range 2 - 12 months since the time of injury in group A and 4.46 months (range 2 - 7 months in group B was observed. Subjective IKDC evaluation was done at the end of 12 months. Ther e was no difference in both the groups in the terms of effusion, passive motion, knee compartment findings, ligament examination, X - ray findings. Functional test and IKDC grade of both the groups showed statistically very highly significant improvement. Ho wever, there was statistically very high Harvest site pathology in group A. CONCLUSION : We found that there is statistically no significant difference in the overall clinical outcome between hamstring autograft with transfix and bone - patellar tendon bone autograft with interference screw except that the patellar tendon group had a greater tendency of having donor site morbidity compared to the hamstring tendon group.

  11. Nonlinear Displacement Discontinuity Model for Generalized Rayleigh Wave in Contact Interface

    Energy Technology Data Exchange (ETDEWEB)

    Kim, No Hyu; Yang, Seung Yong [Korea University of Technology and Education, Cheonan (Korea, Republic of)

    2007-12-15

    Imperfectly jointed interface serves as mechanical waveguide for elastic waves and gives rise to two distinct kinds of guided wave propagating along the interface. Contact acoustic nonlinearity (CAN) is known to plays major role in the generation of these interface waves called generalized Rayleigh waves in non-welded interface. Closed crack is modeled as non-welded interface that has nonlinear discontinuity condition in displacement across its boundary. Mathematical analysis of boundary conditions and wave equation is conducted to investigate the dispersive characteristics of the interface waves. Existence of the generalized Rayleigh wave(interface wave) in nonlinear contact interface is verified in theory where the dispersion equation for the interface wave is formulated and analyzed. It reveals that the interface waves have two distinct modes and that the phase velocity of anti-symmetric wave mode is highly dependent on contact conditions represented by linear and nonlinear dimensionless specific stiffness

  12. Nonlinear Displacement Discontinuity Model for Generalized Rayleigh Wave in Contact Interface

    International Nuclear Information System (INIS)

    Kim, No Hyu; Yang, Seung Yong

    2007-01-01

    Imperfectly jointed interface serves as mechanical waveguide for elastic waves and gives rise to two distinct kinds of guided wave propagating along the interface. Contact acoustic nonlinearity (CAN) is known to plays major role in the generation of these interface waves called generalized Rayleigh waves in non-welded interface. Closed crack is modeled as non-welded interface that has nonlinear discontinuity condition in displacement across its boundary. Mathematical analysis of boundary conditions and wave equation is conducted to investigate the dispersive characteristics of the interface waves. Existence of the generalized Rayleigh wave(interface wave) in nonlinear contact interface is verified in theory where the dispersion equation for the interface wave is formulated and analyzed. It reveals that the interface waves have two distinct modes and that the phase velocity of anti-symmetric wave mode is highly dependent on contact conditions represented by linear and nonlinear dimensionless specific stiffness

  13. Contact resistance of ceramic interfaces between materials used for solid oxide fuel cell applications

    Energy Technology Data Exchange (ETDEWEB)

    Koch, S.

    2002-01-01

    The contact resistance can be divided into two main contributions. The small area of contact between ceramic components results in resistance due to current constriction. Resistive phases or potential barriers at the interface result in an interface contribution to the contact resistance, which may be smaller or larger than the constriction resistance. The contact resistance between pairs of three different materials were analysed (strontium doped lanthanum manganite, yttria stabilised zirconia and strontium and nickel doped lanthanum cobaltite), and the effects of temperature, atmosphere, polarisation and mechanical load on the contact resistance were investigated. The investigations revealed that the mechanical load of a ceramic contact has a high influence on the contact resistance, and generally power law dependence between the contact resistance and the mechanical load was found. The influence of the mechanical load on the contact resistance was ascribed to an area effect. The contact resistance of the investigated materials was dominated by current constriction at high temperatures. The measured contact resistance was comparable to the resistance calculated on basis of the contact areas found by optical and electron microscopy. At low temperatures, the interface contribution to the contact resistance was dominating. The cobaltite interface could be described by one potential barrier at the contact interface, whereas the manganite interfaces required several consecutive potential barriers to model the observed behaviour. The current-voltage behaviour of the YSZ contact interfaces was only weakly non-linear, and could be described by 22{+-}1 barriers in series. Contact interfaces with sinterable contact layers were also investigated, and the measured contact resistance for these interfaces were more than 10 times less than for the other interfaces. (au)

  14. Fetal development of the pulley for muscle insertion tendons: A review and new findings related to the tensor tympani tendon.

    Science.gov (United States)

    Rodríguez-Vázquez, Jose Francisco; Honkura, Yohei; Katori, Yukio; Murakami, Gen; Abe, Hiroshi

    2017-01-01

    The existence of hard tissue pulleys that act to change the direction of a muscle insertion tendon is well known in the human body. These include (1) the trochlea for the extraocular obliquus superior muscle, (2) the pterygoid hamulus for the tensor veli palatini muscle, (3) the deep sulcus on the plantar aspect of the cuboid bone for the peroneus longus tendon, (4) the lesser sciatic notch for the obturator internus muscle, and (5) the bony trochleariformis process for the tensor tympani muscle tendon. In addition, (6) the stapedius muscle tendon shows a lesser or greater angulation at the pyramidal eminence of the temporal bone. Our recent studies have shown that the development of pulleys Nos. 1 and 2 can be explained by a change in the topographical relationship between the pulley and the tendon, that of pulley No. 3 by the rapidly growing calcaneus pushing the tendon, and that of pulley No. 4 by migration of the insertion along the sciatic nerve and gluteus medius tendon. Therefore, in Nos. 1-4, an initially direct tendon curves secondarily and obtains an attachment to the pulley. In case No. 6, the terminal part of the stapedius tendon originates secondarily from the interzone mesenchymal tissue of the incudostapedial joint. In the case of pulley No. 5, we newly demonstrated that its initial phase of development was similar to No. 6, but the tensor tympani tendon achieved a right-angled turn under guidance by a specific fibrous tissue and it migrated along the growing malleus manubrium. Copyright © 2016 Elsevier GmbH. All rights reserved.

  15. Contact Resistance of Ceramic Interfaces Between Materials Used for Solid Oxide Fuel Cell Applications

    DEFF Research Database (Denmark)

    Koch, Søren

    The contact resistance can be divided into two main contributions. The small area of contact between ceramic components results in resistance due to current constriction. Resistive phases or potential barriers at the interface result in an interface contribution to the contact resistance, which may....... The influence of the mechanical load on the contact resistance was ascribed to an area effect. The contact resistance of the investigated materials was dominated by current constric-tion at high temperatures. The measured contact resistance was comparable to the resis-tance calculated on basis of the contact...... areas found by optical and electron microscopy. At low temperatures, the interface contribution to the contact resistance was dominating. The cobaltite interface could be described by one potential barrier at the contact interface, whereas the manganite interfaces required several consecutive potential...

  16. In Vivo Study of Ligament-Bone Healing after Anterior Cruciate Ligament Reconstruction Using Autologous Tendons with Mesenchymal Stem Cells Affinity Peptide Conjugated Electrospun Nanofibrous Scaffold

    Directory of Open Access Journals (Sweden)

    Jingxian Zhu

    2013-01-01

    Full Text Available Electrospinning nanofibrous scaffold was commonly used in tissue regeneration recently. Nanofibers with specific topological characteristics were reported to be able to induce osteogenic differentiation of MSCs. In this in vivo study, autologous tendon grafts with lattice-like nanofibrous scaffold wrapping at two ends of autologous tendon were used to promote early stage of ligament-bone healing after rabbit ACL reconstruction. To utilize native MSCs from bone marrow, an MSCs specific affinity peptide E7 was conjugated to nanofibrous meshes. After 3 months, H-E assessment and specific staining of collagen type I, II, and III showed direct ligament-bone insertion with typical four zones (bone, calcified fibrocartilage, fibrocartilage, and ligament in bioactive scaffold reconstruction group. Diameters of bone tunnel were smaller in nanofibrous scaffold conjugated E7 peptide group than those in control group. The failure load of substitution complex also indicated a stronger ligament-bone insertion healing using bioactive scaffold. In conclusion, lattice-like nanofibrous scaffold with specific MSCs affinity peptide has great potential in promoting early stage of ligament-bone healing after ACL reconstruction.

  17. Treatment with vacuum-assisted closure and cryo-preserved homologous de-epidermalised dermis of complex traumas to the lower limbs with loss of substance, and bones and tendons exposure.

    Science.gov (United States)

    Brandi, C; Grimaldi, L; Nisi, G; Silvestri, A; Brafa, A; Calabrò, M; D'Aniello, C

    2008-12-01

    Lower-limb injuries with loss of tissue and exposure of bones and tendons are an increasing problem. The condition of the wound locally and the patient in general does not always allow immediate and adequate coverage of the structures exposed by the trauma. Therefore, new therapeutic solutions are needed. A reduction in the time that bones and tendons are exposed is essential to achieve complete healing of bone fractures, with reduced risks of infection and less disabling outcomes. The effectiveness of vacuum-assisted closure (VAC) therapy in supporting wound healing and of cryopreserved homologous de-epidermalised dermis (DED) in providing an effective template for re-epithelialisation has been previously reported. We carried out a study to evaluate the effectiveness of the synergistic and combined use of the two methodologies. Eighteen patients with traumatic loss of tissue in the lower limbs, involving exposure of bone and tendon structures, were enrolled in the study. All participants had local, general contraindications to first-instance reconstructions, or both. All patients received a combination of VAC therapy and DED implants. Granulation tissue was obtained in all wounds, with complete coverage of exposed structures. No infections were detected in the cohort, and all patients were prepared for further necessary reconstructive treatments. In our experience, the combination of VAC therapy and DED could, in selected cases, constitute an effective treatment for complex lower limb traumatic injuries with bone and tendon exposure.

  18. Factors Affecting the Longevity and Strength in an In Vitro Model of the Bone–Ligament Interface

    Science.gov (United States)

    Paxton, Jennifer Z.; Donnelly, Kenneth; Keatch, Robert P.; Grover, Liam M.

    2010-01-01

    The interfaces between musculoskeletal tissues with contrasting moduli are morphologically and biochemically adapted to allow the transmission of force with minimal injury. Current methods of tissue engineering ligaments and tendons do not include the interface and this may limit the future clinical success of engineered musculoskeletal tissues. This study aimed to use solid brushite cement anchors to engineer intact ligaments from bone-to-bone, creating a functional musculoskeletal interface in vitro. We show here that modifying anchor shape and cement composition can alter both the longevity and the strength of an in vitro model of the bone–ligament interface: with values reaching 23 days and 21.6 kPa, respectively. These results validate the use of brushite bone cement to engineer the bone–ligament interface in vitro and raise the potential for future use in ligament replacement surgery. PMID:20431953

  19. Single-row versus double-row capsulolabral repair: a comparative evaluation of contact pressure and surface area in the capsulolabral complex-glenoid bone interface.

    Science.gov (United States)

    Kim, Doo-Sup; Yoon, Yeo-Seung; Chung, Hoi-Jeong

    2011-07-01

    Despite the attention that has been paid to restoration of the capsulolabral complex anatomic insertion onto the glenoid, studies comparing the pressurized contact area and mean interface pressure at the anatomic insertion site between a single-row repair and a double-row labral repair have been uncommon. The purpose of our study was to compare the mean interface pressure and pressurized contact area at the anatomic insertion site of the capsulolabral complex between a single-row repair and a double-row repair technique. Controlled laboratory study. Thirty fresh-frozen cadaveric shoulders (mean age, 61 ± 8 years; range, 48-71 years) were used for this study. Two types of repair were performed on each specimen: (1) a single-row repair and (2) a double-row repair. Using pressure-sensitive films, we examined the interface contact area and contact pressure. The mean interface pressure was greater for the double-row repair technique (0.29 ± 0.04 MPa) when compared with the single-row repair technique (0.21 ± 0.03 MPa) (P = .003). The mean pressurized contact area was also significantly greater for the double-row repair technique (211.8 ± 18.6 mm(2), 78.4% footprint) compared with the single-row repair technique (106.4 ± 16.8 mm(2), 39.4% footprint) (P = .001). The double-row repair has significantly greater mean interface pressure and pressurized contact area at the insertion site of the capsulolabral complex than the single-row repair. The double-row repair may be advantageous compared with the single-row repair in restoring the native footprint area of the capsulolabral complex.

  20. Flexor Tendon Injuries

    Science.gov (United States)

    ... All Topics A-Z Videos Infographics Symptom Picker Anatomy Bones Joints Muscles Nerves Vessels Tendons About Hand Surgery What is ... Hand Therapist? Media Find a Hand Surgeon Home Anatomy ... fields From * To * DESCRIPTION The muscles that bend (flex) the fingers are called flexor ...

  1. Nanoscale roughness contact in a slider-disk interface.

    Science.gov (United States)

    Hua, Wei; Liu, Bo; Yu, Shengkai; Zhou, Weidong

    2009-07-15

    The nanoscale roughness contact between molecularly smooth surfaces of a slider-disk interface in a hard disk drive is analyzed, and the lubricant behavior at very high shear rate is presented. A new contact model is developed to study the nanoscale roughness contact behavior by classifying various forms of contact into slider-lubricant contact, slider-disk elastic contact and plastic contact. The contact pressure and the contact probabilities of the three types of contact are investigated. The new contact model is employed to explain and provide insight to an interesting experimental result found in a thermal protrusion slider. The protrusion budget for head surfing in the lubricant, which is the ideal state for contact recording, is also discussed.

  2. Nanoscale roughness contact in a slider-disk interface

    International Nuclear Information System (INIS)

    Hua Wei; Liu Bo; Yu Shengkai; Zhou Weidong

    2009-01-01

    The nanoscale roughness contact between molecularly smooth surfaces of a slider-disk interface in a hard disk drive is analyzed, and the lubricant behavior at very high shear rate is presented. A new contact model is developed to study the nanoscale roughness contact behavior by classifying various forms of contact into slider-lubricant contact, slider-disk elastic contact and plastic contact. The contact pressure and the contact probabilities of the three types of contact are investigated. The new contact model is employed to explain and provide insight to an interesting experimental result found in a thermal protrusion slider. The protrusion budget for head surfing in the lubricant, which is the ideal state for contact recording, is also discussed.

  3. Icariin Promotes Tendon-Bone Healing during Repair of Rotator Cuff Tears: A Biomechanical and Histological Study.

    Science.gov (United States)

    Ye, Chenyi; Zhang, Wei; Wang, Shengdong; Jiang, Shuai; Yu, Yuanbin; Chen, Erman; Xue, Deting; Chen, Jianzhong; He, Rongxin

    2016-10-25

    To investigate whether the systematic administration of icariin (ICA) promotes tendon-bone healing after rotator cuff reconstruction in vivo, a total of 64 male Sprague Dawley rats were used in a rotator cuff injury model and underwent rotator cuff reconstruction (bone tunnel suture fixation). Rats from the ICA group ( n = 32) were gavage-fed daily with ICA at 0.125 mg/g, while rats in the control group ( n = 32) received saline only. Micro-computed tomography, biomechanical tests, serum ELISA (calcium; Ca, alkaline phosphatase; AP, osteocalcin; OCN) and histological examinations (Safranin O and Fast Green staining, type I, II and III collagen (Col1, Col2, and Col3), CD31, and vascular endothelial growth factor (VEGF)) were analyzed two and four weeks after surgery. In the ICA group, the serum levels of AP and OCN were higher than in the control group. More Col1-, Col2-, CD31-, and VEGF-positive cells, together with a greater degree of osteogenesis, were detected in the ICA group compared with the control group. During mechanical testing, the ICA group showed a significantly higher ultimate failure load than the control group at both two and four weeks. Our results indicate that the systematic administration of ICA could promote angiogenesis and tendon-bone healing after rotator cuff reconstruction, with superior mechanical strength compared with the controls. Treatment for rotator cuff injury using systematically-administered ICA could be a promising strategy.

  4. Phase contrast X-ray imaging at the bone-cartilage interface

    International Nuclear Information System (INIS)

    Che Ismail, E.; Gundogdu, O.; Bradley, D.A.

    2008-01-01

    Full text: Phase contrast X-ray imaging is a simple technique to investigate various biological samples. At Surrey, the bone-cartilage interface is one of the biological samples which actively been studied. Bone-cartilage interface study gives a particular interest in this research as the degeneration of cartilage is the hallmark of the degenerative joint disease such as osteoarthritis. We have been applying the phase contrast imaging technique in studying the bone-cartilage interface, obtaining information on anatomical features such as the cartilage, blood vessel, tide mark and cement line. Our samples range from dry bone-cartilage to wet bone-cartilage tissue. This work will briefly review the basic supporting physics of the study. It also shows some of the images and other results that we have obtained to-date. Fig. 1 shows examples obtained using the X-ray tube system at the University of Surrey

  5. Identification of Novel Equine (Equus caballus Tendon Markers Using RNA Sequencing

    Directory of Open Access Journals (Sweden)

    Jan M. Kuemmerle

    2016-11-01

    Full Text Available Although several tendon-selective genes exist, they are also expressed in other musculoskeletal tissues. As cell and tissue engineering is reliant on specific molecular markers to discriminate between cell types, tendon-specific genes need to be identified. In order to accomplish this, we have used RNA sequencing (RNA-seq to compare gene expression between tendon, bone, cartilage and ligament from horses. We identified several tendon-selective gene markers, and established eyes absent homolog 2 (EYA2 and a G-protein regulated inducer of neurite outgrowth 3 (GPRIN3 as specific tendon markers using RT-qPCR. Equine tendon cells cultured as three-dimensional spheroids expressed significantly greater levels of EYA2 than GPRIN3, and stained positively for EYA2 using immunohistochemistry. EYA2 was also found in fibroblast-like cells within the tendon tissue matrix and in cells localized to the vascular endothelium. In summary, we have identified EYA2 and GPRIN3 as specific molecular markers of equine tendon as compared to bone, cartilage and ligament, and provide evidence for the use of EYA2 as an additional marker for tendon cells in vitro.

  6. Rupture of Achilles Tendon : Usefulness of Ultrasonography

    International Nuclear Information System (INIS)

    Kim, Nam Hyeon; Ki, Won Woo; Yoon, Kwon Ha; Kim, Song Mun; Shin, Myeong Jin; Kwon, Soon Tae

    1996-01-01

    To differentiate a complete rupture of Achilles tendon from an incomplete one which is important because its treatment is quite different. And it is necessary to know the exact site of the rupture preoperatively. Fifteen cases of fourteen patients which were diagnosed as Achilles tendon rupture by ultrasonography and surgery were reviewed. We compared sonographic rupture site with surgical findings. Ultrasonographic criteria for differentiation of complete and incomplete rupture was defined as follows : the discreteness, which means the proximal intervening hypoechogenicity to the interface echogenicity of distal margin of ruptured tendon : the slant sign, which represents the interface of ruptured distal margin which was seen over the 3/4 of the thickness of the tendon without intervening low echogeneicity : the invagination sign, which means the echogenic invagination from Kager triangle into posterior aspect of Achilles tendon over the half thickness of the tendon. The sites of complete tendon rupture were exactly corresponded to surgical finding in four cases of ten complete ruptures. And the discrepancy between sonographic and surgical findings in the site of complete rupture was 1.2 ± 0.4 cm in six cases. Three of ten complete ruptures showed the discreteness sign, all of ten showed the slant sign and two of ten showed the invagination sign. It is helpful to differentiate a complete from incomplete rupture of the Achilles tendon and to localize the site of the complete rupture with the ultrasonographic evaluation

  7. Effect of laceration and trimming of a tendon on the coefficient of friction along the A2 pulley: an in vitro study on turkey tendon.

    Science.gov (United States)

    Hajipour, L; Gulihar, A; Dias, J

    2010-08-01

    We carried out lacerations of 50%, followed by trimming, in ten turkey flexor tendons in vitro and measured the coefficient of friction at the tendon-pulley interface with loads of 200 g and 400 g and in 10 degrees , 30 degrees, 50 degrees and 70 degrees of flexion. Laceration increased the coefficient of friction from 0.12 for the intact tendon to 0.3 at both the test loads. Trimming the laceration reduced the coefficient of friction to 0.2. An exponential increase in the gliding resistance was found at 50 degrees and 70 degrees of flexion (p = 0.02 and p = 0.003, respectively) following trimming compared to that of the intact tendon. We concluded that trimming partially lacerated flexor tendons will reduce the gliding resistance at the tendon-pulley interface, but will lead to fragmentation and triggering of the tendon at higher degrees of flexion and loading. We recommend that higher degrees of flexion be avoided during early post-operative rehabilitation following trimming of a flexor tendon.

  8. Magnetotherapy: The quest for tendon regeneration.

    Science.gov (United States)

    Pesqueira, Tamagno; Costa-Almeida, Raquel; Gomes, Manuela E

    2018-05-09

    Tendons are mechanosensitive tissues that connect and transmit the forces generated by muscles to bones by allowing the conversion of mechanical input into biochemical signals. These physical forces perform the fundamental work of preserving tendon homeostasis assuring body movements. However, overloading causes tissue injuries, which leads us to the field of tendon regeneration. Recently published reviews have broadly shown the use of biomaterials and different strategies to attain tendon regeneration. In this review, our focus is the use of magnetic fields as an alternative therapy, which has demonstrated clinical relevance in tendon medicine because of their ability to modulate cell fate. Yet the underlying cellular and molecular mechanisms still need to be elucidated. While providing a brief outlook about specific signalling pathways and intracellular messengers as framework in play by tendon cells, application of magnetic fields as a subcategory of physical forces is explored, opening up a compelling avenue to enhance tendon regeneration. We outline here useful insights on the effects of magnetic fields both at in vitro and in vivo levels, particularly on the expression of tendon genes and inflammatory cytokines, ultimately involved in tendon regeneration. Subsequently, the potential of using magnetically responsive biomaterials in tendon tissue engineering is highlighted and future directions in magnetotherapy are discussed. © 2018 Wiley Periodicals, Inc.

  9. ConKit: a python interface to contact predictions.

    Science.gov (United States)

    Simkovic, Felix; Thomas, Jens M H; Rigden, Daniel J

    2017-07-15

    Recent advances in protein residue contact prediction algorithms have led to the emergence of many new methods and a variety of file formats. We present ConKit , an open source, modular and extensible Python interface which allows facile conversion between formats and provides an interface to analyses of sequence alignments and sets of contact predictions. ConKit is available via the Python Package Index. The documentation can be found at http://www.conkit.org . ConKit is licensed under the BSD 3-Clause. hlfsimko@liverpool.ac.uk or drigden@liverpool.ac.uk. Supplementary data are available at Bioinformatics online. © The Author(s) 2017. Published by Oxford University Press.

  10. Atomistic simulations of contact area and conductance at nanoscale interfaces.

    Science.gov (United States)

    Hu, Xiaoli; Martini, Ashlie

    2017-11-09

    Atomistic simulations were used to study conductance across the interface between a nanoscale gold probe and a graphite surface with a step edge. Conductance on the graphite terrace was observed to increase with load and be approximately proportional to contact area calculated from the positions of atoms in the interface. The relationship between area and conductance was further explored by varying the position of the contact relative to the location of the graphite step edge. These simulations reproduced a previously-reported current dip at step edges measured experimentally and the trend was explained by changes in both contact area and the distribution of distances between atoms in the interface. The novel approach reported here provides a foundation for future studies of the fundamental relationships between conductance, load and surface topography at the atomic scale.

  11. Anterior cruciate ligament reconstruction using bone plug-free quadriceps tendon autograft: intermediate-term clinical outcome after 24-36 months.

    Science.gov (United States)

    Schulz, Arndt P; Lange, Vivien; Gille, Justus; Voigt, Christine; Fröhlich, Susanne; Stuhr, Markus; Jürgens, Christian

    2013-01-01

    Although known as a possible graft option for decades, quadriceps tendon grafts have often been termed a second-line graft option. We report a consecutive case series using this method as the primary treatment line. The rationale for this study was to evaluate the midterm results of this method in a prospective and consecutive case series. The primary study question was to determine the clinical results 24-36 months after primary anterior cruciate ligament (ACL) reconstruction using a bone plug-free quadriceps tendon autograft fixed with bioabsorbable cross-pins. The study population included 55 patients, of whom 24 were female (43.6%). The mean age at the index procedure was 31.7 years (15-58 years). All patients received an ACL construction using a bone block-free quadriceps tendon graft fixed with resorbable cross-pins. The postoperative regimen included partial weight-bearing for 3 weeks and flexion limited to 90° for six weeks; an orthosis was not used. The mean follow-up duration was 29.5 months (24.3-38.5 months) after the index procedure. The International Knee Documentation Committee (IKDC) subjective score and examination form was assessed, as well as the Lysholm and Gillquist score and the Tegner activity index. The Rolimeter arthrometer was used to assess the anterior laxity of the knee. Graft harvesting was possible in all cases; a bony extension was never required. On average, graft length was measured at 8.8 cm (7.5-10 cm). The mean IKDC subjective score at follow-up was 80.44 points (55.17-100 points, standard deviation [SD] 12.05). The mean preinjury Tegner activity index was 4.98 (2-7) compared to a mean value of 4.16 (2-7, SD 0.8) at follow-up. There was a mean loss of 0.82 index points. The average Lysholm and Gillquist score was 89 points (65-100, SD 17.7). Of the results, 89.1% were in the good or very good groups; in one case (1.8%), the result was poor, while the rest were fair. ACL reconstruction using a bone plug-free quadriceps tendon

  12. Uniformly-dispersed nanohydroxapatite-reinforced poly(ε-caprolactone) composite films for tendon tissue engineering application

    Energy Technology Data Exchange (ETDEWEB)

    Tong, Shi Yun [Department of Mechanical Engineering, National University of Singapore, 9 Engineering Drive 1, Singapore 117 576 (Singapore); Wang, Zuyong, E-mail: zuyong.nus@gmail.com [Department of Mechanical Engineering, National University of Singapore, 9 Engineering Drive 1, Singapore 117 576 (Singapore); Lim, Poon Nian [Department of Mechanical Engineering, National University of Singapore, 9 Engineering Drive 1, Singapore 117 576 (Singapore); Wang, Wilson [Department of Orthopaedic Surgery, National University of Singapore, 5 Lower Kent Ridge Road, Singapore 119 074 (Singapore); Thian, Eng San, E-mail: mpetes@nus.edu.sg [Department of Mechanical Engineering, National University of Singapore, 9 Engineering Drive 1, Singapore 117 576 (Singapore)

    2017-01-01

    Regeneration of injuries at tendon-to-bone interface (TBI) remains a challenging issue due to the complex tissue composition involving both soft tendon tissues and relatively hard bone tissues. Tissue engineering using polymeric/ceramic composites has been of great interest to generate scaffolds for tissue's healing at TBI. Herein, we presented a novel method to blend polymers and bioceramics for tendon tissue engineering application. A homogeneous composite comprising of nanohydroxyapatite (nHA) particles in poly(ε-caprolactone) (PCL) matrix was obtained using a combination of solvent and mechanical blending process. X-ray diffraction analysis showed that the as-fabricated PCL/nHA composite film retained phase-pure apatite and semi-crystalline properties of PCL. Infrared spectroscopy spectra confirmed that the PCL/nHA composite film exhibited the characteristics functional groups of PCL and nHA, without alteration to the chemical properties of the composite. The incorporation of nHA resulted in PCL/nHA composite film with improved mechanical properties such as Young's Modulus and ultimate tensile stress, which were comparable to that of the native human rotator tendon. Seeding with human tenocytes, cells attached on the PCL/nHA composite film, and after 14 days of culturing, these cells could acquire elongated morphology without induced cytotoxicity. PCL/nHA composite film could also result in increased cell metabolism with prolonged culturing, which was comparable to that of the PCL group and higher than that of the nHA group. All these results demonstrated that the developed technique of combining solvent and mechanical blending could be applied to fabricate composite films with potential for tendon tissue engineering applications. - Highlights: • A novel method fabricating polymeric/nanoceramic composite film was proposed. • The method involved solvent and mechanical blending to form a homogeneous film. • The film retained physicochemical

  13. Head-disk interface nanotribology for Tbit/inch2 recording densities: near-contact and contact recording

    Science.gov (United States)

    Vakis, Antonis I.; Polycarpou, Andreas A.

    2010-06-01

    In the effort to achieve Tbit/inch2 recording densities, thermal fly-height control (TFC) nanotechnology was developed to effectively reduce the clearance (which is of the order of a few nanometres) at the head-disk interface (HDI) of hard-disk drives. In this work, we present a model of the HDI that can predict the dynamic flying and nanotribological contacting behaviour, allowing for accurate predictions and characterization of the operating regime as a function of TFC actuation. A geometric model for TFC is presented and an improved definition of contact at the interface is developed in the presence of nanoscale topographical roughness and dynamic microwaviness. A new methodology is proposed for the calculation of the nominal area of contact, which affects both near- and at-contact behaviour, while the stiffening of the air bearing force with TFC actuation is also accounted for. Slider behaviour is analysed by quantifying the approach, jump-to-contact, lubricant and solid contact regimes of operation and identifying the critical and optimum TFC actuations. The feasibility of near-contact, light molecularly thin lubricant contact versus solid contact recording is explored under the effect of the interfacial forces and stresses present at the HDI. The clearance and the state of vibrations are analysed and design guidelines are proposed for improved performance.

  14. Head-disk interface nanotribology for Tbit/inch2 recording densities: near-contact and contact recording

    International Nuclear Information System (INIS)

    Vakis, Antonis I; Polycarpou, Andreas A

    2010-01-01

    In the effort to achieve Tbit/inch 2 recording densities, thermal fly-height control (TFC) nanotechnology was developed to effectively reduce the clearance (which is of the order of a few nanometres) at the head-disk interface (HDI) of hard-disk drives. In this work, we present a model of the HDI that can predict the dynamic flying and nanotribological contacting behaviour, allowing for accurate predictions and characterization of the operating regime as a function of TFC actuation. A geometric model for TFC is presented and an improved definition of contact at the interface is developed in the presence of nanoscale topographical roughness and dynamic microwaviness. A new methodology is proposed for the calculation of the nominal area of contact, which affects both near- and at-contact behaviour, while the stiffening of the air bearing force with TFC actuation is also accounted for. Slider behaviour is analysed by quantifying the approach, jump-to-contact, lubricant and solid contact regimes of operation and identifying the critical and optimum TFC actuations. The feasibility of near-contact, light molecularly thin lubricant contact versus solid contact recording is explored under the effect of the interfacial forces and stresses present at the HDI. The clearance and the state of vibrations are analysed and design guidelines are proposed for improved performance.

  15. Biofabrication of soft tissue templates for engineering the bone-ligament interface.

    Science.gov (United States)

    Harris, Ella; Liu, Yurong; Cunniffe, Grainne; Morrissey, David; Carroll, Simon; Mulhall, Kevin; Kelly, Daniel J

    2017-10-01

    Regenerating damaged tissue interfaces remains a significant clinical challenge, requiring recapitulation of the structure, composition, and function of the native enthesis. In the ligament-to-bone interface, this region transitions from ligament to fibrocartilage, to calcified cartilage and then to bone. This gradation in tissue types facilitates the transfer of load between soft and hard structures while minimizing stress concentrations at the interface. Previous attempts to engineer the ligament-bone interface have utilized various scaffold materials with an array of various cell types and/or biological cues. The primary goal of this study was to engineer a multiphased construct mimicking the ligament-bone interface by driving differentiation of a single population of mesenchymal stem cells (MSCs), seeded within blended fibrin-alginate hydrogels, down an endochondral, fibrocartilaginous, or ligamentous pathway through spatial presentation of growth factors along the length of the construct within a custom-developed, dual-chamber culture system. MSCs within these engineered constructs demonstrated spatially distinct regions of differentiation, adopting either a cartilaginous or ligamentous phenotype depending on their local environment. Furthermore, there was also evidence of spatially defined progression toward an endochondral phenotype when chondrogenically primed MSCs within this construct were additionally exposed to hypertrophic cues. The study demonstrates the feasibility of engineering spatially complex soft tissues within a single MSC laden hydrogel through the defined presentation of biochemical cues. This novel approach represents a new strategy for engineering the ligament-bone interface. Biotechnol. Bioeng. 2017;114: 2400-2411. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  16. Assessment of rotatory instability after anterior cruciate ligament reconstruction with a bone-patellar tendon-bone graft

    International Nuclear Information System (INIS)

    Tashiro, Yasutaka; Okazaki, Ken; Miura, Hiromasa

    2010-01-01

    Anatomically oriented anterior cruciate ligament (ACL) reconstruction has been advocated recently, but its effect on rotatory instability remains to be cleared objectively. The purpose of this study was to quantitatively evaluate rotatory instability in ACL reconstructed knees with a bone-patellar tendon-bone (BTB) graft using an open MRI system. Eighteen subjects underwent arthroscopic ACL reconstruction with a BTB graft. The tibial tunnel was placed in the center of the ACL footprint. The femoral tunnel was drilled transtibially at the 10:00 to 10:30-o'clock position for the right knees. Subjects were examined using a Slocum anterolateral rotatory instability test in open MRI. Anterior tibial translation was measured at the medial and lateral compartments by evaluating sagittal images. Anterior knee stability was evaluated using the KT-2000 arthrometer. The clinical knee function was assessed with the Lysholm and Tegner scoring scales before and after the surgery. Side-to-side differences of anterolateral tibial translation was 0.1 mm. Side-to-side difference on KT-2000 arthrometer measurement was 1.8 mm. The Lysholm score improved to 96 and the latest Tegner score reached substantially the preinjury level. ACL reconstruction with a BTB graft was successful in restoring rotatory stability as well as anterior stability and knee function. (author)

  17. Scanning electron microscopy (SEM) and X-ray dispersive spectrometry evaluation of direct laser metal sintering surface and human bone interface: a case series.

    Science.gov (United States)

    Mangano, Carlo; Piattelli, Adriano; Raspanti, Mario; Mangano, Francesco; Cassoni, Alessandra; Iezzi, Giovanna; Shibli, Jamil Awad

    2011-01-01

    Recent studies have shown that direct laser metal sintering (DLMS) produces structures with complex geometry and consequently that allow better osteoconductive properties. The aim of this patient report was to evaluate the early bone response to DLMS implant surface retrieved from human jaws. Four experimental DLMS implants were inserted in the posterior mandible of four patients during conventional dental implant surgery. After 8 weeks, the micro-implants and the surrounding tissue were removed and prepared for scanning electron microscopy (SEM) and histomorphometric analysis to evaluate the bone-implant interface. The SEM and EDX evaluations showed a newly formed tissue composed of calcium and phosphorus. The bone-to-implant contact presented a mean of 60.5 ± 11.6%. Within the limits of this patient report, data suggest that the DLMS surfaces presented a close contact with the human bone after a healing period of 8 weeks.

  18. Mapping the articular contact area of the long head of the biceps tendon on the humeral head.

    Science.gov (United States)

    Morris, Brent J; Byram, Ian R; Lathrop, Ray A; Dunn, Warren R; Kuhn, John E

    2014-01-01

    The purpose of this investigation was to calculate the contact surface area of the long head of the biceps (LHB) in neutral position and abduction. We sought to determine whether the LHB articulates with the humeral head in a consistent pattern comparing articular contact area in neutral position and abduction. Eleven fresh frozen matched cadaveric shoulders were analyzed. The path of the biceps tendon on the articular surface of the humeral head and the total articular surface were digitized using a MicronTracker 2 H3-60 three-dimensional optical tracker. Contact surface area was significantly less in abduction than in neutral position (P = 0.002) with a median ratio of 41% (36%, 47.5%). Ratios of contact area in neutral position to full articular surface area were consistent between left and right shoulders (rho = 1, P = 0.017) as were ratios of abduction area to full articular surface area (rho = 0.97, P = 0.005). The articular contact surface area is significantly greater in neutral position than abduction. The ratios of articular contact surface areas to total humeral articular surface areas have a narrow range and are consistent between left and right shoulders of the same cadaver.

  19. Incorporating contact angles in the surface tension force with the ACES interface curvature scheme

    Science.gov (United States)

    Owkes, Mark

    2017-11-01

    In simulations of gas-liquid flows interacting with solid boundaries, the contact line dynamics effect the interface motion and flow field through the surface tension force. The surface tension force is directly proportional to the interface curvature and the problem of accurately imposing a contact angle must be incorporated into the interface curvature calculation. Many commonly used algorithms to compute interface curvatures (e.g., height function method) require extrapolating the interface, with defined contact angle, into the solid to allow for the calculation of a curvature near a wall. Extrapolating can be an ill-posed problem, especially in three-dimensions or when multiple contact lines are near each other. We have developed an accurate methodology to compute interface curvatures that allows for contact angles to be easily incorporated while avoiding extrapolation and the associated challenges. The method, known as Adjustable Curvature Evaluation Scale (ACES), leverages a least squares fit of a polynomial to points computed on the volume-of-fluid (VOF) representation of the gas-liquid interface. The method is tested by simulating canonical test cases and then applied to simulate the injection and motion of water droplets in a channel (relevant to PEM fuel cells).

  20. An electrospun polydioxanone patch for the localisation of biological therapies during tendon repair

    Directory of Open Access Journals (Sweden)

    O Hakimi

    2012-10-01

    Full Text Available Rotator cuff tendon pathology is thought to account for 30-70 % of all shoulder pain. For cases that have failed conservative treatment, surgical re-attachment of the tendon to the bone with a non-absorbable suture is a common option. However, the failure rate of these repairs is high, estimated at up to 75 %. Studies have shown that in late disease stages the tendon itself is extremely degenerate, with reduced cell numbers and poor matrix organisation. Thus, it has been suggested that adding biological factors such as platelet rich plasma (PRP and mesenchymal stem cells could improve healing. However, the articular capsule of the glenohumeral joint and the subacromial bursa are large spaces, and injecting beneficial factors into these sites does not ensure localisation to the area of tendon damage.Thus, the aim of this study was to develop a biocompatible patch for improving the healing rates of rotator cuff repairs. The patch will create a confinement around the repair area and will be used to guide injections to the vicinity of the surgical repair.Here, we characterised and tested a preliminary prototype of the patch utilising in vitro tools and primary tendon-derived cells, showing exceptional biocompatibility despite rapid degradation, improved cell attachment and that cells could migrate across the patch towards a chemo-attractant. Finally, we showed the feasibility of detecting the patch using ultrasound and injecting liquid into the confinement ex vivo. There is a potential for using this scaffold in the surgical repair of interfaces such as the tendon insertion in the rotator cuff, in conjunction with beneficial factors.

  1. Metal deposition at the bone-cartilage interface in articular cartilage

    Energy Technology Data Exchange (ETDEWEB)

    Kaabar, W. [Department of Physics, University of Surrey, Guildford GU2 7XH (United Kingdom)], E-mail: w.kaabar@surrey.ac.uk; Daar, E.; Gundogdu, O.; Jenneson, P.M. [Department of Physics, University of Surrey, Guildford GU2 7XH (United Kingdom); Farquharson, M.J. [Department of Radiography, School of Allied Health Sciences, City University, London EC1V 0HB (United Kingdom); Webb, M.; Jeynes, C. [Surrey Ion Beam Centre, University of Surrey, Guildford GU2 7XH (United Kingdom); Bradley, D.A. [Department of Physics, University of Surrey, Guildford GU2 7XH (United Kingdom)

    2009-03-15

    There is a growing interest being shown in the changes occurring in elemental distribution at the bone-cartilage interface, the changes either being a result of mechanical damage or disease. In particular, such investigations have tended to concern the elemental alterations associated with the osteoarthritic wear and tear damage occurring to the cartilage and subchondral bone of synovial joints or that associated with disease processes such as rheumatic arthritis. Present studies examine sections of femoral head obtained from total hip replacement surgery, use being made of micro-proton-induced X-ray emission ({mu}-PIXE) and the Rutherford back scattering (RBS) techniques. Enhancements of Zn, Ca and P have been observed at the bone-cartilage interface. Further, the concentration of Zn in spongy bone underlying the subchondral surface of a section of the femoral head has been measured, obtaining 136 {mu}g g{sup -1} bone, the presence of Ca and P at the same position being 0.235 and 0.0451 g g{sup -1} bone, respectively. These values are slightly different to figures recently published by other authors using similar techniques.

  2. A relationship between spinal new bone formation in ankylosing spondylitis and the sonographically determined Achilles tendon enthesophytes.

    Science.gov (United States)

    Aydin, Sibel Zehra; Can, Meryem; Alibaz-Oner, Fatma; Keser, Gokhan; Kurum, Esra; Inal, Vedat; Yazisiz, Veli; Birlik, Merih; Emmungil, Hakan; Atagunduz, Pamir; Direskeneli, Haner; McGonagle, Dennis; Pay, Salih

    2016-03-01

    Spinal new bone formation is a major but incompletely understood manifestation of ankylosing spondylitis (AS). We explored the relationship between spinal new bone formation and ultrasound (US)-determined Achilles enthesophytes to test the hypothesis that spinal new bone formation is part of a generalized enthesis bone-forming phenotype. A multicenter, case control study of 225 consecutive AS patients and 95 age/body mass index (BMI) matched healthy controls (HC) was performed. US scans of Achilles tendons and cervical and lumbar spine radiographs were obtained. All images were centrally scored by one investigator for US and one for radiographs, blinded to medical data. The relation between syndesmophytes (by modified Stoke Ankylosing Spondylitis Spine Score (mSASSS) and the number of syndesmophytes) and enthesophytes (with a semi-quantitative scoring of the US findings) was investigated. AS patients had significantly higher US enthesophyte scores than HCs (2.1(1.6) vs. 1.6(1.6); p = 0.004). The difference was significant in males (p = 0.001) but not in females (p = 0.5). The enthesophyte scores significantly correlated with mSASSS scores (ρ = 0.274, p gender-specific phenotype that could be a useful marker predicting of new bone formation.

  3. THE EFFECTS OF AN EARLY RETURN TO TRAINING ON THE BONE-TENDON JUNCTION POST-ACUTE MICRO-INJURY HEALING

    Directory of Open Access Journals (Sweden)

    Lin Wang

    2012-06-01

    Full Text Available Bone-tendon junction (BTJ overuse injuries are common athletic and occupational problems. BTJ injuries may sometimes be caused by resuming training too early after injury. To study the effects of post-injury resuming training within 48 hours on the acute injury healing process, as it is often the case for athletes. Twelve mature female rabbits were assigned to one of the following groups: acute injury (AI, n = 6, post-injury early return to training (PIERT, n = 6 and normal control (CON, n = 6. Tissue specimens were harvested at week 4. The radiological and histological characteristics of the AI and PIERT groups were compared among the groups. The trabecular thickness of the PIERT group was significantly different from those of the AI and CON group. A histological evaluation revealed poor collagen fibre alignment, extensive scar tissue and lowered cell density in the AI and PIERT groups compared with the CON group, but no significant differences were observed between the AI group and the PIERT group. The fibrocartilage zone and proteoglycan area in the PIERT group were significantly different from those in AI group. No differences were observed in the Total VOI volume (TV, Object volume (OBV, Percent object volume (BV/TV and trabecular number (Tb.N among the AI, PIERT and CON groups. In conclusion, a repeatable animal model of bone-tendon junction acute micro-damage by puncture was established. Resuming training in 48 hours did not significantly deteriorate the BTJ injury healing, but improved bone remodelling and increased fibrocartilage zone thickness

  4. An advanced glycation endproduct (AGE)-rich diet promotes accumulation of AGEs in Achilles tendon

    DEFF Research Database (Denmark)

    Skovgaard, Dorthe; Svensson, Rene B; Scheijen, Jean

    2017-01-01

    the relationship between AGE content in the diet and accumulation of AGEs in weight-bearing animal Achilles tendon. Two groups of mice (C57BL/6Ntac) were fed with either high-fat diet low in AGEs high-fat diet (HFD) (n = 14) or normal diet high in AGEs (ND) (n = 11). AGE content in ND was six to 50-fold higher......Advanced Glycation Endproducts (AGEs) accumulate in long-lived tissue proteins like collagen in bone and tendon causing modification of the biomechanical properties. This has been hypothesized to raise the risk of orthopedic injury such as bone fractures and tendon ruptures. We evaluated...... was measured using ultraperformance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) and pentosidine with high-pressure liquid chromatography (HPLC) with fluorescent detection. AGEs in Achilles tendon were higher than in tail tendon for CML (P

  5. Stem Cell Applications in Tendon Disorders: A Clinical Perspective

    Directory of Open Access Journals (Sweden)

    Mark Young

    2012-01-01

    Full Text Available Tendon injuries are a common cause of morbidity and a significant health burden on society. Tendons are structural tissues connecting muscle to bone and are prone to tearing and tendinopathy, an overuse or degenerative condition that is characterized by failed healing and cellular depletion. Current treatments, for tendon tear are conservative, surgical repair or surgical scaffold reconstruction. Tendinopathy is treated by exercises, injection therapies, shock wave treatments or surgical tendon debridement. However, tendons usually heal with fibrosis and scar tissue, which has suboptimal tensile strength and is prone to reinjury, resulting in lifestyle changes with activity restriction. Preclinical studies show that cell therapies have the potential to regenerate rather than repair tendon tissue, a process termed tenogenesis. A number of different cell lines, with varying degrees of differentiation, have being evaluated including stem cells, tendon derived cells and dermal fibroblasts. Even though cellular therapies offer some potential in treating tendon disorders, there have been few published clinical trials to determine the ideal cell source, the number of cells to administer, or the optimal bioscaffold for clinical use.

  6. Friction coefficient and effective interference at the implant-bone interface.

    Science.gov (United States)

    Damm, Niklas B; Morlock, Michael M; Bishop, Nicholas E

    2015-09-18

    Although the contact pressure increases during implantation of a wedge-shaped implant, friction coefficients tend to be measured under constant contact pressure, as endorsed in standard procedures. Abrasion and plastic deformation of the bone during implantation are rarely reported, although they define the effective interference, by reducing the nominal interference between implant and bone cavity. In this study radial forces were analysed during simulated implantation and explantation of angled porous and polished implant surfaces against trabecular bone specimens, to determine the corresponding friction coefficients. Permanent deformation was also analysed to determine the effective interference after implantation. For the most porous surface tested, the friction coefficient initially increased with increasing normal contact stress during implantation and then decreased at higher contact stresses. For a less porous surface, the friction coefficient increased continually with normal contact stress during implantation but did not reach the peak magnitude measured for the rougher surface. Friction coefficients for the polished surface were independent of normal contact stress and much lower than for the porous surfaces. Friction coefficients were slightly lower for pull-out than for push-in for the porous surfaces but not for the polished surface. The effective interference was as little as 30% of the nominal interference for the porous surfaces. The determined variation in friction coefficient with radial contact force, as well as the loss of interference during implantation will enable a more accurate representation of implant press-fitting for simulations. Copyright © 2015 Elsevier Ltd. All rights reserved.

  7. Mapping the Articular Contact Area of the Long Head of the Biceps Tendon on the Humeral Head

    Directory of Open Access Journals (Sweden)

    Brent J. Morris

    2014-01-01

    Full Text Available The purpose of this investigation was to calculate the contact surface area of the long head of the biceps (LHB in neutral position and abduction. We sought to determine whether the LHB articulates with the humeral head in a consistent pattern comparing articular contact area in neutral position and abduction. Eleven fresh frozen matched cadaveric shoulders were analyzed. The path of the biceps tendon on the articular surface of the humeral head and the total articular surface were digitized using a MicronTracker 2 H3-60 three-dimensional optical tracker. Contact surface area was significantly less in abduction than in neutral position (P=0.002 with a median ratio of 41% (36%, 47.5%. Ratios of contact area in neutral position to full articular surface area were consistent between left and right shoulders (rho=1, P=0.017 as were ratios of abduction area to full articular surface area (rho= 0.97, P=0.005. The articular contact surface area is significantly greater in neutral position than abduction. The ratios of articular contact surface areas to total humeral articular surface areas have a narrow range and are consistent between left and right shoulders of the same cadaver.

  8. Frontal plane fractures of the accessory carpal bone and implications for the carpal sheath of the digital flexor tendons.

    Science.gov (United States)

    Minshall, G J; Wright, I M

    2014-09-01

    Accurate radiological and ultrasonographic descriptions of frontal plane fractures of the accessory carpal bone (ACB) are lacking, and implications of these fractures for the carpal sheath and its contents have not previously been reported. Aims were as follows: 1) to describe the location and radiological features of frontal plane fractures of the ACB; 2) to document communication of displaced fractures with the carpal sheath and consequent injury to the deep digital flexor tendon (DDFT); 3) to describe ultrasonographic identification of lesions; and 4) to report tenoscopic evaluation and treatment. Retrospective case series. Analysis of frontal plane fractures of the ACB referred to a single hospital between 2006 and 2012, including review of radiographic, ultrasonographic and tenoscopic images. Nine fractures were identified, of which 8 displaced fractures all communicated with the carpal sheath. Comminuted fragments and/or protruding fracture margins lacerated the lateral margin of the enclosed DDFT. This was identifiable ultrasonographically and confirmed at tenoscopy in 7 cases. Treatment in these horses consisted of removal of torn tendon tissue together with fragmentation and protuberant fracture edges, and 7 of 7 cases returned to work. One horse with a nondisplaced fracture was managed with immobilisation; the fracture healed, and the horse returned to work. One horse with a displaced fracture was retired to stud. Frontal plane fractures of the ACB occur palmar to the groove in its lateral margin for the tendon of insertion of ulnaris lateralis. Comminuted fragments can displace distally within the carpal sheath to a mid-metacarpal level or abaxially to lie extrathecally, lateral to the parent bone. Displaced fractures communicate with the carpal sheath and traumatise the DDFT. © 2013 EVJ Ltd.

  9. Characterization of calcium and zinc spatial distributions at the fibrocartilage zone of bone-tendon junction by synchrotron radiation-based micro X-ray fluorescence analysis combined with backscattered electron imaging

    Science.gov (United States)

    Lu, Hongbin; Chen, Can; Wang, Zhanwen; Qu, Jin; Xu, Daqi; Wu, Tianding; Cao, Yong; Zhou, Jingyong; Zheng, Cheng; Hu, Jianzhong

    2015-09-01

    Tendon attaches to bone through a functionally graded fibrocartilage zone, including uncalcified fibrocartilage (UF), tidemark (TM) and calcified fibrocartilage (CF). This transition zone plays a pivotal role in relaxing load transfer between tendon and bone, and serves as a boundary between otherwise structurally and functionally distinct tissue types. Calcium and zinc are believed to play important roles in the normal growth, mineralization, and repair of the fibrocartilage zone of bone-tendon junction (BTJ). However, spatial distributions of calcium and zinc at the fibrocartilage zone of BTJ and their distribution-function relationship are not totally understood. Thus, synchrotron radiation-based micro X-ray fluorescence analysis (SR-μXRF) in combination with backscattered electron imaging (BEI) was employed to characterize the distributions of calcium and zinc at the fibrocartilage zone of rabbit patella-patellar tendon complex (PPTC). For the first time, the unique distributions of calcium and zinc at the fibrocartilage zone of the PPTC were clearly mapped by this method. The distributions of calcium and zinc at the fibrocartilage zone of the PPTC were inhomogeneous. A significant accumulation of zinc was exhibited in the transition region between UF and CF. The highest zinc content (3.17 times of that of patellar tendon) was found in the TM of fibrocartilage zone. The calcium content began to increase near the TM and increased exponentially across the calcified fibrocartilage region towards the patella. The highest calcium content (43.14 times of that of patellar tendon) was in the transitional zone of calcified fibrocartilage region and the patella, approximately 69 μm from the location with the highest zinc content. This study indicated, for the first time, that there is a differential distribution of calcium and zinc at the fibrocartilage zone of PPTC. These observations reveal new insights into region-dependent changes across the fibrocartilage zone of

  10. [Evaluation of early physiotherapy in patients after surgical treatment of cruciate ligament injury by bone-tendon-bone method].

    Science.gov (United States)

    Klupiński, Kamil; Krekora, Katarzyna; Woldańska-Okońska, Marta

    2014-01-01

    Anterior cruciate ligament (ACL) is one of the most important structures of the knee joint. It has a stabilizing function and causes sliding movement between the articular surfaces. Most frequently there comes to the anterior cruciate ligament injury during practicing sports such as skiing, football, sports which require sudden turns and those which are associated with jumps for height like basketball and volleyball. The aim of study was to evaluate of the outcomes of complex physiotherapy after reconstruction of anterior cruciate ligament by bone -tendon-bone (BTB) method. The study involved 41 patients, 8 women and 33 men, aged 20 to 45 years, body height 1.60-1.90 cm and body weight 50-100 kg. The patients were divided into two groups. Group I included 26 patients (3 women and 23 men) after arthroscopic ACL reconstruction. Group II--control-group included 15 patients (5 women and 10 men) after ACL injury but not subjected to the ligament reconstruction. The patients from both groups underwent rehabilitation according to the same rehabilitation program suggested by the Medical Magnus Clinic in Lodz, which consisted in performing daily exercises in open and closed kinetic chains. All group I and II patients were examined three times: after surgery (before the start of the rehabilitation), in the sixth week of rehabilitation and 12 weeks afterwards. The clinical examination included: measurement of the range of movement in the knee joint, the measurement of musculoskeletal strength with Lovett scale, knee pain assessment using Visual Analog Scale (VAS), transpatellar anthropometric measurement of the knee joint, linear measurements of the thigh and shin (at two points: 5 and 10 cm above the patellar apex and at two points: 5 and 10 cm below the patellar base). Introduction of early highly specialized physiotherapy has been demonstrated to contribute to the improvement of the rehabilitation outcomes and to the shortening of the therapy. A statistically significant

  11. Contact angle and detachment energy of shape anisotropic particles at fluid-fluid interfaces.

    Science.gov (United States)

    Anjali, Thriveni G; Basavaraj, Madivala G

    2016-09-15

    The three phase contact angle of particles, a measure of its wettability, is an important factor that greatly influences their behaviour at interfaces. It is one of the principal design parameters for potential applications of particles as emulsion/foam stabilizers, functional coatings and other novel materials. In the present work, the effect of size, shape and surface chemistry of particles on their contact angle is investigated using the gel trapping technique, which facilitates the direct visualization of the equilibrium position of particles at interfaces. The contact angle of hematite particles of spherocylindrical, peanut and cuboidal shapes, hematite-silica core-shell and silica shells is reported at a single particle level. The spherocylindrical and peanut shaped particles are always positioned with their major axis parallel to the interface. However, for cuboidal particles at air-water as well as decane-water interfaces, different orientations namely - face-up, edge-up and the vertex-up - are observed. The influence of gravity on the equilibrium position of the colloidal particles at the interface is studied using the hematite-silica core-shell particles and the silica shells. The measured contact angle values are utilized in the calculations of the detachment and surface energies of the hematite particles adsorbed at the interface. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Osseointegration of zirconia implants: an SEM observation of the bone-implant interface.

    Science.gov (United States)

    Depprich, Rita; Zipprich, Holger; Ommerborn, Michelle; Mahn, Eduardo; Lammers, Lydia; Handschel, Jörg; Naujoks, Christian; Wiesmann, Hans-Peter; Kübler, Norbert R; Meyer, Ulrich

    2008-11-06

    The successful use of zirconia ceramics in orthopedic surgery led to a demand for dental zirconium-based implant systems. Because of its excellent biomechanical characteristics, biocompatibility, and bright tooth-like color, zirconia (zirconium dioxide, ZrO2) has the potential to become a substitute for titanium as dental implant material. The present study aimed at investigating the osseointegration of zirconia implants with modified ablative surface at an ultrastructural level. A total of 24 zirconia implants with modified ablative surfaces and 24 titanium implants all of similar shape and surface structure were inserted into the tibia of 12 Göttinger minipigs. Block biopsies were harvested 1 week, 4 weeks or 12 weeks (four animals each) after surgery. Scanning electron microscopy (SEM) analysis was performed at the bone implant interface. Remarkable bone attachment was already seen after 1 week which increased further to intimate bone contact after 4 weeks, observed on both zirconia and titanium implant surfaces. After 12 weeks, osseointegration without interposition of an interfacial layer was detected. At the ultrastructural level, there was no obvious difference between the osseointegration of zirconia implants with modified ablative surfaces and titanium implants with a similar surface topography. The results of this study indicate similar osseointegration of zirconia and titanium implants at the ultrastructural level.

  13. A damage mechanics based general purpose interface/contact element

    Science.gov (United States)

    Yan, Chengyong

    Most of the microelectronics packaging structures consist of layered substrates connected with bonding materials, such as solder or epoxy. Predicting the thermomechanical behavior of these multilayered structures is a challenging task in electronic packaging engineering. In a layered structure the most complex part is always the interfaces between the strates. Simulating the thermo-mechanical behavior of such interfaces, is the main theme of this dissertation. The most commonly used solder material, Pb-Sn alloy, has a very low melting temperature 180sp°C, so that the material demonstrates a highly viscous behavior. And, creep usually dominates the failure mechanism. Hence, the theory of viscoplasticity is adapted to describe the constitutive behavior. In a multilayered assembly each layer has a different coefficient of thermal expansion. Under thermal cycling, due to heat dissipated from circuits, interfaces and interconnects experience low cycle fatigue. Presently, the state-of-the art damage mechanics model used for fatigue life predictions is based on Kachanov (1986) continuum damage model. This model uses plastic strain as a damage criterion. Since plastic strain is a stress path dependent value, the criterion does not yield unique damage values for the same state of stress. In this dissertation a new damage evolution equation based on the second law of thermodynamic is proposed. The new criterion is based on the entropy of the system and it yields unique damage values for all stress paths to the final state of stress. In the electronics industry, there is a strong desire to develop fatigue free interconnections. The proposed interface/contact element can also simulate the behavior of the fatigue free Z-direction thin film interconnections as well as traditional layered interconnects. The proposed interface element can simulate behavior of a bonded interface or unbonded sliding interface, also called contact element. The proposed element was verified against

  14. Anterior cruciate ligament reconstruction using bone plug-free quadriceps tendon autograft: intermediate-term clinical outcome after 24–36 months

    Directory of Open Access Journals (Sweden)

    Schulz AP

    2013-11-01

    Full Text Available Arndt P Schulz,1 Vivien Lange,2 Justus Gille,1 Christine Voigt,3 Susanne Fröhlich,4 Markus Stuhr,1 Christian Jürgens5 1Department of Orthopedics, Trauma, and Sports Medicine, University Hospital Lübeck, Lübeck, Germany; 2Department of Rehabilitation, Sana Regio Klinikum, Wedel, Germany; 3Department of Sports Medicine and Arthroscopy, Diakoniekrankenhaus Friederikenstift, Hannover, Germany; 4Department of Orthopedics, University of Rostock, Rostock, Germany; 5Department of Orthopedics, Trauma, and Sports Medicine, BG Trauma Hospital Hamburg, Hamburg, Germany Introduction: Although known as a possible graft option for decades, quadriceps tendon grafts have often been termed a second-line graft option. We report a consecutive case series using this method as the primary treatment line. The rationale for this study was to evaluate the midterm results of this method in a prospective and consecutive case series. The primary study question was to determine the clinical results 24–36 months after primary anterior cruciate ligament (ACL reconstruction using a bone plug-free quadriceps tendon autograft fixed with bioabsorbable cross-pins. Materials and methods: The study population included 55 patients, of whom 24 were female (43.6%. The mean age at the index procedure was 31.7 years (15–58 years. All patients received an ACL construction using a bone block-free quadriceps tendon graft fixed with resorbable cross-pins. The postoperative regimen included partial weight-bearing for 3 weeks and flexion limited to 90° for six weeks; an orthosis was not used. The mean follow-up duration was 29.5 months (24.3–38.5 months after the index procedure. The International Knee Documentation Committee (IKDC subjective score and examination form was assessed, as well as the Lysholm and Gillquist score and the Tegner activity index. The Rolimeter arthrometer was used to assess the anterior laxity of the knee. Results: Graft harvesting was possible in all cases

  15. The Mineral–Collagen Interface in Bone

    Science.gov (United States)

    2015-01-01

    The interface between collagen and the mineral reinforcement phase, carbonated hydroxyapatite (cAp), is essential for bone’s remarkable functionality as a biological composite material. The very small dimensions of the cAp phase and the disparate natures of the reinforcement and matrix are essential to the material’s performance but also complicate study of this interface. This article summarizes what is known about the cAp-collagen interface in bone and begins with descriptions of the matrix and reinforcement roles in composites, of the phases bounding the interface, of growth of cAp growing within the collagen matrix, and of the effect of intra- and extrafibrilar mineral on determinations of interfacial properties. Different observed interfacial interactions with cAp (collagen, water, non-collagenous proteins) are reviewed; experimental results on interface interactions during loading are reported as are their influence on macroscopic mechanical properties; conclusions of numerical modeling of interfacial interactions are also presented. The data suggest interfacial interlocking (bending of collagen molecules around cAp nanoplatelets) and water-mediated bonding between collagen and cAp are essential to load transfer. The review concludes with descriptions of areas where new research is needed to improve understanding of how the interface functions. PMID:25824581

  16. The interfascicular matrix enables fascicle sliding and recovery in tendon, and behaves more elastically in energy storing tendons.

    Science.gov (United States)

    Thorpe, Chavaunne T; Godinho, Marta S C; Riley, Graham P; Birch, Helen L; Clegg, Peter D; Screen, Hazel R C

    2015-12-01

    While the predominant function of all tendons is to transfer force from muscle to bone and position the limbs, some tendons additionally function as energy stores, reducing the cost of locomotion. Energy storing tendons experience extremely high strains and need to be able to recoil efficiently for maximum energy storage and return. In the equine forelimb, the energy storing superficial digital flexor tendon (SDFT) has much higher failure strains than the positional common digital extensor tendon (CDET). However, we have previously shown that this is not due to differences in the properties of the SDFT and CDET fascicles (the largest tendon subunits). Instead, there is a greater capacity for interfascicular sliding in the SDFT which facilitates the greater extensions in this particular tendon (Thorpe et al., 2012). In the current study, we exposed fascicles and interfascicular matrix (IFM) from the SDFT and CDET to cyclic loading followed by a test to failure. The results show that IFM mechanical behaviour is not a result of irreversible deformation, but the IFM is able to withstand cyclic loading, and is more elastic in the SDFT than in the CDET. We also assessed the effect of ageing on IFM properties, demonstrating that the IFM is less able to resist repetitive loading as it ages, becoming stiffer with increasing age in the SDFT. These results provide further indications that the IFM is important for efficient function in energy storing tendons, and age-related alterations to the IFM may compromise function and predispose older tendons to injury. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  17. Atelocollagen Enhances the Healing of Rotator Cuff Tendon in Rabbit Model.

    Science.gov (United States)

    Suh, Dong-Sam; Lee, Jun-Keun; Yoo, Ji-Chul; Woo, Sang-Hun; Kim, Ga-Ram; Kim, Ju-Won; Choi, Nam-Yong; Kim, Yongdeok; Song, Hyun-Seok

    2017-07-01

    Failure of rotator cuff healing is a common complication despite the rapid development of surgical repair techniques for the torn rotator cuff. To verify the effect of atelocollagen on tendon-to-bone healing in the rabbit supraspinatus tendon compared with conventional cuff repair. Controlled laboratory study. A tear of the supraspinatus tendon was created and repaired in 46 New Zealand White rabbits. They were then randomly allocated into 2 groups (23 rabbits per group; 15 for histological and 8 for biomechanical test). In the experimental group, patch-type atelocollagen was implanted between bone and tendon during repair; in the control group, the torn tendon was repaired without atelocollagen. Each opposite shoulder served as a sham (tendon was exposed only). Histological evaluation was performed at 4, 8, and 12 weeks. Biomechanical tensile strength was tested 12 weeks after surgery. Histological evaluation scores of the experimental group (4.0 ± 1.0) were significantly superior to those of the control group (7.7 ± 2.7) at 12 weeks ( P = .005). The load to failure was significantly higher in the experimental group (51.4 ± 3.9 N) than in the control group (36.4 ± 5.9 N) ( P = .001). Histological and biomechanical studies demonstrated better results in the experimental group using atelocollagen in a rabbit model of the supraspinatus tendon tear. Atelocollagen patch could be used in the cuff repair site to enhance healing.

  18. Optimizing pressurized contact area in rotator cuff repair: the diamondback repair.

    Science.gov (United States)

    Burkhart, Stephen S; Denard, Patrick J; Obopilwe, Elifho; Mazzocca, Augustus D

    2012-02-01

    The purpose of this study was to compare tendon-bone footprint contact area over time under physiologic loads for 4 different rotator cuff repair techniques: single row (SR), triangle double row (DR), chain-link double row (CL), and diamondback double row (DBK). A supraspinatus tear was created in 28 human cadavers. Tears were fixed with 1 of 4 constructs: SR, DR, CL, or DBK. Immediate post-repair measurements of pressurized contact area were taken in neutral rotation and 0° of abduction. After a static tensile load, pressurized contact area was observed over a 160-minute period after repair. Cyclic loading was then performed. The DBK repair had the highest pressurized contact area initially, as well as the highest pressurized contact area and lowest percentage decrease in pressurized contact area after 160 minutes of testing. The DBK repair had significantly larger initial pressurized contact than CL (P = .003) and SR (P = .004) but not DR (P = .06). The DBK technique was the only technique that produced a pressurized contact area that exceeded the native footprint both at initial repair (P = .01) and after 160 minutes of testing (P = .01). DBK had a significantly larger mean pressurized contact area than all the repairs after 160 minutes of testing (P = .01). DBK had a significantly larger post-cyclic loading pressurized contact area than CL (P = .01) and SR (P = .004) but not DR (P = .07). This study showed that a diamondback repair (a modification of the transosseous repair) can significantly increase the rotator cuff pressurized contact area in comparison with other standard rotator cuff repair constructs when there is sufficient tendon mobility to perform a double-row repair without excessive tension on the repair site. The persistent pressurized contact area of a DBK repair may be desirable to enhance healing potential when there is sufficient tendon mobility to perform a double-row repair, particularly for large or massive rotator cuff tears where it is

  19. Tendon Interposition and Ligament Reconstruction with ECRL Tendon in the Late Stages of Kienböck’s Disease: A Cadaver Study

    Directory of Open Access Journals (Sweden)

    Nazım Karalezli

    2013-01-01

    Full Text Available Background. The optimal surgical treatment for Kienböck’s disease with stages IIIB and IV remains controversial. A cadaver study was carried out to evaluate the use of coiled extensor carpi radialis longus tendon for tendon interposition and a strip obtained from the same tendon for ligament reconstruction in the late stages of Kienböck’s disease. Methods. Coiled extensor carpi radialis longus tendon was used to fill the cavity of the excised lunate, and a strip obtained from this tendon was sutured onto itself after passing through the scaphoid and the triquetrum acting as a ligament to preserve proximal row integrity. Biomechanical tests were carried out in order to evaluate this new ligamentous reconstruction. Results. It was biomechanically confirmed that the procedure was effective against axial compression and distributed the upcoming mechanical stress to the distal row. Conclusion. Extensor carpi radialis longus tendon has not been used for tendon interposition and ligament reconstruction in the treatment of this disease before. In view of the biomechanical data, the procedure seems to be effective for the stabilization of scaphoid and carpal bones.

  20. Dynamic Model of Contact Interface between Stator and Rotor

    Directory of Open Access Journals (Sweden)

    ZengHui Zhao

    2013-01-01

    Full Text Available Based on the equivalent principle, a linear spring contact model was established for the friction layer between stator and rotor. Different contact conditions were described by a distance index δ. Detailed analysis of the nonlinear contact behavior especially the static and dynamic slipping was carried on using a space-time equation. A contact deflection angle was proposed to quantitatively express the influence of friction force on the output performance. A more precision simulation model was established based on the theoretical analysis, and influences of different preload pressures and elastic modulus Em of friction layer on output performance were analyzed. The results showed the simulation results had very good consistency with experimental results, and the model could well reflect the output characteristics of contact interface.

  1. Sources of adult mesenchymal stem cells for ligament and tendon tissue engineering.

    Science.gov (United States)

    Dhinsa, Baljinder S; Mahapatra, Anant N; Khan, Wasim S

    2015-01-01

    Tendon and ligament injuries are common, and repair slowly with reduced biomechanical properties. With increasing financial demands on the health service and patients to recover from tendon and ligament injuries faster, and with less morbidity, health professionals are exploring new treatment options. Tissue engineering may provide the answer, with its unlimited source of natural cells that in the correct environment may improve repair and regeneration of tendon and ligament tissue. Mesenchymal stem cells have demonstrated the ability to self renew and have multilineage differentiation potential. The use of bone marrow-derived mesenchymal stem cells has been reported, however significant in vitro culture expansion is required due to the low yield of cells, which has financial implications. Harvesting of bone marrow cells also has associated morbidity. Several studies have looked at alternative sources for mesenchymal stem cells. Reports in literature from animal studies have been encouraging, however further work is required. This review assesses the potential sources of mesenchymal stem cells for tissue engineering in tendons and ligaments.

  2. Clinico-roentgenological semiotics of malignant contact bone tumors

    International Nuclear Information System (INIS)

    Akperbekov, A.A.; Polatkhanova, K.B.; Murtuzaeva, Z.D.

    1986-01-01

    Bone changes were analyzed in 42 patients (aged 18 to 65) with malignant contact bone tumors. Probable causes of their origin were discussed. Of 42 patients corticopleural cancer (Pancoast's tumor) was noted in 24, skin cancer developing against a background of a chronic inflammatory process or trauma, was noted in 13, sarcomatous soft tissue tumors in 5. A method of roentgenography using routine and spot radiographs was used for X-ray examination of the patients. In some cases the examination was supplemented with hard and soft X-ray films, tomography and electroroentgenography

  3. The influence of orientation and practical size on the interface fracture of a bone-nano composite cement

    International Nuclear Information System (INIS)

    Ilik, Igor; Khandaker, Morshed

    2010-01-01

    Clinical follow-up studies in cemented total hip arthroplasties found that femoral prosthesis loosening is caused by the fracture of the bone-cement interfaces. The research objectives were to determine whether orientation of the bone has any influence on the interface fracture strength, and to determine whether inclusion of micro/nano sizes MgO particles on Cobalt HV bone cement has any influence on the interface fracture strength. Flexural tests were conducted on five groups of specimens to find Young Modulus and bending strength: (1) longitudinal bone, (2) transverse bone, (3) pure cement particles, (4) cement with 36 im and 27 nm MgO particles, and (5) cement with 27nm MgO particles. Also, fracture tests were conducted on six groups of bone-cement specimen to find interface fracture toughness: (1) longitudinal bone-cement without MgO particles, (2) transverse bone-cement without MgO particles, (3) longitudinal bone-cement with 36 im MgO particles, (4) transverse bone-cement with 36 im MgO particles, (5) , longitudinal bone-cement with 27 nm MgO particles, and (6) transverse bone-cement with 27 nm MgO particles. Transverse bone specimen was 14% stiffer than longitudinal specimen, while bending strength and fracture toughness of longitudinal specimen was 29% and 2.6 times lower than the transverse specimen, respectively. Reduction of Young's modulus (7.3%), bending strength (27%) and fracture toughness (16%) was observed by the inclusion of microsize MgO particles, and a reduction of the Young's Modulus (19%), bending strength (21%),and fracture toughness (19%) for nanosize MgO particles. The interface toughness of the transverse bone infused with 27nm MgO was about 6 times higher than transverse bone infused with 36 im particles of MgO. Preliminary studies show that orientation of the bone has significant influence on the interface fracture. MgO particles size have a significant effect on the strength of the bone - cement interface.(Author)

  4. Porous metal revision shells for management of contained acetabular bone defects at a mean follow-up of six years: a comparison between up to 50% bleeding host bone contact and more than 50% contact.

    Science.gov (United States)

    Sternheim, A; Backstein, D; Kuzyk, P R T; Goshua, G; Berkovich, Y; Safir, O; Gross, A E

    2012-02-01

    We report the use of porous metal acetabular revision shells in the treatment of contained bone loss. The outcomes of 53 patients with ≤ 50% acetabular bleeding host bone contact were compared with a control group of 49 patients with > 50% to 85% bleeding host bone contact. All patients were treated with the same type of trabecular metal acetabular revision shell. The mean age at revision was 62.4 years (42 to 80) and the mean follow-up of both groups was 72.4 months (60 to 102). Clinical, radiological and functional outcomes were assessed. There were four (7.5%) mechanical failures in the ≤ 50% host bone contact group and no failures in the > 50% host bone contact group (p = 0.068). Out of both groups combined there were four infections (3.9%) and five recurrent dislocations (4.9%) with a stable acetabular component construct that were revised to a constrained liner. Given the complexity of the reconstructive challenge, porous metal revision acetabular shells show acceptable failure rates at five to ten years' follow-up in the setting of significant contained bone defects. This favourable outcome might be due to the improved initial stability achieved by a high coefficient of friction between the acetabular implant and the host bone, and the high porosity, which affords good bone ingrowth.

  5. Influence of hole transport material/metal contact interface on perovskite solar cells

    Science.gov (United States)

    Lei, Lei; Zhang, Shude; Yang, Songwang; Li, Xiaomin; Yu, Yu; Wei, Qingzhu; Ni, Zhichun; Li, Ming

    2018-06-01

    Interfaces have a significant impact on the performance of perovskite solar cells. This work investigated the influence of hole transport material/metal contact interface on photovoltaic behaviours of perovskite solar devices. Different hole material/metal contact interfaces were obtained by depositing the metal under different conditions. High incident kinetic energy metal particles were proved to penetrate and embed into the hole transport material. These isolated metal particles in hole transport materials capture holes and increase the apparent carrier transport resistance of the hole transport layer. Sample temperature was found to be of great significance in metal deposition. Since metal vapour has a high temperature, the deposition process accumulated a large amount of heat. The heat evaporated the additives in the hole transport layer and decreased the hole conductivity. On the other hand, high temperature may cause iodization of the metal contact.

  6. Quadriceps Tendon Autograft Medial Patellofemoral Ligament Reconstruction.

    Science.gov (United States)

    Fink, Christian; Steensen, Robert; Gföller, Peter; Lawton, Robert

    2018-06-01

    Critically evaluate the published literature related to quadriceps tendon (QT) medial patellofemoral ligament (MPFL) reconstruction. Hamstring tendon (HT) MPFL reconstruction techniques have been shown to successfully restore patella stability, but complications including patella fracture are reported. Quadriceps tendon (QT) reconstruction techniques with an intact graft pedicle on the patella side have the advantage that patella bone tunnel drilling and fixation are no longer needed, reducing risk of patella fracture. Several QT MPFL reconstruction techniques, including minimally invasive surgical (MIS) approaches, have been published with promising clinical results and fewer complications than with HT techniques. Parallel laboratory studies have shown macroscopic anatomy and biomechanical properties of QT are more similar to native MPFL than hamstring (HS) HT, suggesting QT may more accurately restore native joint kinematics. Quadriceps tendon MPFL reconstruction, via both open and MIS techniques, have promising clinical results and offer valuable alternatives to HS grafts for primary and revision MPFL reconstruction in both children and adults.

  7. [Researches on biomechanics of micro-implant-bone interface and optimum design of micro implant's neck].

    Science.gov (United States)

    Deng, Feng; Zhang, Lei; Zhang, Yi; Song, Jin-lin; Fan, Yuboa

    2007-07-01

    To compare and analyze the stress distribution at the micro-implant-bone interface based on the different micro-implant-bone conditioned under orthodontic load, and to optimize the design of micro implant's neck. An adult skull with all tooth was scanned by spiral CT, and the data were imported into computer for three-dimensional reconstruction with software Mimics 9.0. The three dimensional finite element models of three micro-implant-bone interfaces(initial stability, full osseointegration and fibrous integration) were analyzed by finite element analysis software ABAQUS6.5. The primary stress distributions of different micro-implant-bone conditions were evaluated when 2N force was loaded. Then the diameter less than 1.5 mm of the micro implant's neck was added with 0.2 mm, to compare the stress distribution of the modified micro-implant-bone interface with traditional type. The stress mostly concentrated on the neck of micro implant and the full osseointegration interface in all models showed the lowest strain level. Compared with the traditional type, the increasing diameter neck of the micro implant obviously decreased the stress level in all the three conditions. The micro-implant-bone interface and the diameter of micro implant's neck both are the important influence factors to the stress distribution of micro implant.

  8. Factors influencing the tensile strength of repaired Achilles tendon: a biomechanical experiment study.

    Science.gov (United States)

    Jielile, Jiasharete; Bai, Jing Ping; Sabirhazi, Gulnur; Redat, Darebai; Yilihamu, Tuoheti; Xinlin, Baoltri; Hu, Geyang; Tang, Bin; Liang, Bing; Sun, Qi

    2010-10-01

    Operative treatment has been advocated as the method of choice to repair Achilles tendon rupture as surgery results in reduced re-rupture rate and faster rehabilitation. Many surgical techniques have been introduced allowing for postoperative early motion of the ankle joint. However, it is currently very difficult for surgeons to determine the optimal treatment conditions for ruptured Achilles tendon with an increasing number of end-to-end suture methods, suture materials, and epitenon suture techniques. In the present biomechanical experiment study based on an orthogonal design, thirty-two New Zealand white rabbits received Achilles tendon tenotomy and subsequent operative treatment to repair the tendon employing four end-to-end suture methods, four suture materials, and four epitenon suture techniques. The tensile strength of the repaired Achilles tendon was investigated at four rehabilitation periods, and in comparison with the results of another sixteen rabbits with normal Achilles tendons. The end-to-end suture method contributed most to the final Achilles tendon tensile strength in addition to rehabilitation period, with the highest values occurring with the use of the parachute-like ("Pa" bone) suture method. The other two factors, namely, suture material and epitenon suture technique, had relatively little influence on the results. The parachute-like ("Pa" bone) surgical technique is superior to the other three end-to-end suture methods, with enhanced tensile strength of the repaired tendon. This method allows for postoperative early kinesitherapy of the ankle and knee joints. Therefore, this technique is highly recommended in clinical situations for treatment of ruptured Achilles tendon. 2010 Elsevier Ltd. All rights reserved.

  9. In Vitro Mimetic Models for the Bone-Cartilage Interface Regeneration.

    Science.gov (United States)

    Bicho, Diana; Pina, Sandra; Oliveira, J Miguel; Reis, Rui L

    2018-01-01

    In embryonic development, pure cartilage structures are in the basis of bone-cartilage interfaces. Despite this fact, the mature bone and cartilage structures can vary greatly in composition and function. Nevertheless, they collaborate in the osteochondral region to create a smooth transition zone that supports the movements and forces resulting from the daily activities. In this sense, all the hierarchical organization is involved in the maintenance and reestablishment of the equilibrium in case of damage. Therefore, this interface has attracted a great deal of interest in order to understand the mechanisms of regeneration or disease progression in osteoarthritis. With that purpose, in vitro tissue models (either static or dynamic) have been studied. Static in vitro tissue models include monocultures, co-cultures, 3D cultures, and ex vivo cultures, mostly cultivated in flat surfaces, while dynamic models involve the use of bioreactors and microfluidic systems. The latter have emerged as alternatives to study the cellular interactions in a more authentic manner over some disadvantages of the static models. The current alternatives of in vitro mimetic models for bone-cartilage interface regeneration are overviewed and discussed herein.

  10. Pulsed electromagnetic field therapy improves tendon-to-bone healing in a rat rotator cuff repair model.

    Science.gov (United States)

    Tucker, Jennica J; Cirone, James M; Morris, Tyler R; Nuss, Courtney A; Huegel, Julianne; Waldorff, Erik I; Zhang, Nianli; Ryaby, James T; Soslowsky, Louis J

    2017-04-01

    Rotator cuff tears are common musculoskeletal injuries often requiring surgical intervention with high failure rates. Currently, pulsed electromagnetic fields (PEMFs) are used for treatment of long-bone fracture and lumbar and cervical spine fusion surgery. Clinical studies examining the effects of PEMF on soft tissue healing show promising results. Therefore, we investigated the role of PEMF on rotator cuff healing using a rat rotator cuff repair model. We hypothesized that PEMF exposure following rotator cuff repair would improve tendon mechanical properties, tissue morphology, and alter in vivo joint function. Seventy adult male Sprague-Dawley rats were assigned to three groups: bilateral repair with PEMF (n = 30), bilateral repair followed by cage activity (n = 30), and uninjured control with cage activity (n = 10). Rats in the surgical groups were sacrificed at 4, 8, and 16 weeks. Control group was sacrificed at 8 weeks. Passive joint mechanics and gait analysis were assessed over time. Biomechanical analysis and μCT was performed on left shoulders; histological analysis on right shoulders. Results indicate no differences in passive joint mechanics and ambulation. At 4 weeks the PEMF group had decreased cross-sectional area and increased modulus and maximum stress. At 8 weeks the PEMF group had increased modulus and more rounded cells in the midsubstance. At 16 weeks the PEMF group had improved bone quality. Therefore, results indicate that PEMF improves early tendon healing and does not alter joint function in a rat rotator cuff repair model. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:902-909, 2017. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  11. Modified Kidner procedure utilizing a Mitek bone anchor.

    Science.gov (United States)

    Dawson, D M; Julsrud, M E; Erdmann, B B; Jacobs, P M; Ringstrom, J B

    1998-01-01

    The recent development of small bone suture anchors has created several potential applications in reconstructive surgery of the foot. Mitek bone anchors are simple to insert, require less aggressive dissection and surgical time than reefing of the redundant posterior tibial tendon, and are a reliable method of tendon-to-bone fixation. Mitek bone anchors are an excellent technique for the treatment of redundant tibialis posterior tendon following a modified Kidner procedure. In modified Kidner procedures involving an excessively large os tibiale externum, Mitek anchoring of the redundant tibialis posterior tendon to the navicular bone is an excellent means for secure plication of the posterior tibial tendon in cases involving intraoperative tendon laxity. A description of the Mitek Anchor System and technique of application in a modified Kinder procedure is presented. The purpose of this study was to describe patient satisfaction and long-term clinical outcomes of the modified Kinder procedure with and without the Mitek bone anchoring system. A retrospective study of the modified Kinder procedure was performed with 13 patients being evaluated, seven with Mitek anchoring and six without. The University of Maryland 100-point Painful Foot Center Scoring System was modified to be more specific to the modified Kinder procedure for assessment of subjective long-term results. Patient overall satisfaction was rated good to excellent by 85.6% of patients in the Mitek group and by 100% of patients in the non-Mitek group. Use of the Mitek anchor allowed for quicker postoperative recovery to resumption of ambulation without assistive devices (average of 3 weeks vs. 4.42 weeks) and a quicker return to pain-free ambulation in normal shoegear (average of 4 weeks vs. 6 weeks). Mitek anchoring of the tibialis posterior tendon, theoretically, increases medial arch support as evidenced by 14% of the Mitek group and 67% of the non-Mitek group requiring postoperative orthotics.

  12. Mineralization behavior and interface properties of BG-PVA/bone composite implants in simulated body fluid

    Energy Technology Data Exchange (ETDEWEB)

    Ma Yanxuan; Zheng Yudong; Huang Xiaoshan; Xi Tingfei; Han Dongfei [School of Materials Science and Engineering, Beijing University of Science and Technology, Beijing 100083 (China); Lin Xiaodan [College of Materials Science and Engineering, South China University of Technology, Guangzhou 510640 (China); Song Wenhui, E-mail: zhengyudong@mater.ustb.edu.c, E-mail: wenhui.song@brunel.ac.u [Wolfson Center for Materials Processing, School of Engineering and Design, Brunel University, West London, UB8 3PH (United Kingdom)

    2010-04-15

    Due to the non-bioactivity and poor conjunction performance of present cartilage prostheses, the main work here is to develop the bioactive glass-polyvinyl alcohol hydrogel articular cartilage/bone (BG-PVA/bone) composite implants. The essential criterion for a biomaterial to bond with living bone is well-matched mechanical properties as well as biocompatibility and bioactivity. In vitro studies on the formation of a surface layer of carbonate hydroxyl apatite (HCA) and the corresponding variation of the properties of biomaterials are imperative for their clinical application. In this paper, the mineralization behavior and variation of the interface properties of BG-PVA/bone composites were studied in vitro by using simulated body fluid (SBF). The mineralization and HCA layer formed on the interface between the BG-PVA hydrogel and bone in SBF could provide the composites with bioactivity and firmer combination. The compression property, shear strength and interface morphology of BG-PVA/bone composite implants varying with the immersion time in SBF were characterized. Also, the influence laws of the immersion time, content of BG in the composites and aperture of bones to the mineralization behavior and interface properties were investigated. The good mineralization behavior and enhanced conjunction performance of BG-PVA/bone composites demonstrated that this kind of composite implant might be more appropriate cartilage replacements.

  13. Mineralization behavior and interface properties of BG-PVA/bone composite implants in simulated body fluid.

    Science.gov (United States)

    Ma, Yanxuan; Zheng, Yudong; Huang, Xiaoshan; Xi, Tingfei; Lin, Xiaodan; Han, Dongfei; Song, Wenhui

    2010-04-01

    Due to the non-bioactivity and poor conjunction performance of present cartilage prostheses, the main work here is to develop the bioactive glass-polyvinyl alcohol hydrogel articular cartilage/bone (BG-PVA/bone) composite implants. The essential criterion for a biomaterial to bond with living bone is well-matched mechanical properties as well as biocompatibility and bioactivity. In vitro studies on the formation of a surface layer of carbonate hydroxyl apatite (HCA) and the corresponding variation of the properties of biomaterials are imperative for their clinical application. In this paper, the mineralization behavior and variation of the interface properties of BG-PVA/bone composites were studied in vitro by using simulated body fluid (SBF). The mineralization and HCA layer formed on the interface between the BG-PVA hydrogel and bone in SBF could provide the composites with bioactivity and firmer combination. The compression property, shear strength and interface morphology of BG-PVA/bone composite implants varying with the immersion time in SBF were characterized. Also, the influence laws of the immersion time, content of BG in the composites and aperture of bones to the mineralization behavior and interface properties were investigated. The good mineralization behavior and enhanced conjunction performance of BG-PVA/bone composites demonstrated that this kind of composite implant might be more appropriate cartilage replacements.

  14. Tendon synovial cells secrete fibronectin in vivo and in vitro

    International Nuclear Information System (INIS)

    Banes, A.J.; Link, G.W.; Bevin, A.G.; Peterson, H.D.; Gillespie, Y.; Bynum, D.; Watts, S.; Dahners, L.

    1988-01-01

    The chemistry and cell biology of the tendon have been largely overlooked due to the emphasis on collagen, the principle structural component of the tendon. The tendon must not only transmit the force of muscle contraction to bone to effect movement, but it must also glide simultaneously over extratendonous tissues. Fibronectin is classified as a cell attachment molecule that induces cell spreading and adhesion to substratum. The external surface of intact avian flexor tendon stained positively with antibody to cellular fibronectin. However, if the surface synovial cells were first removed with collagenase, no positive reaction with antifibronectin antibody was detected. Analysis of immunologically stained frozen sections of tendon also revealed fibronectin at the tendon synovium, but little was associated with cells internal in tendon. The staining pattern with isolated, cultured synovial cells and fibroblasts from the tendon interior substantiated the histological observations. Analysis of polyacrylamide gel profiles of 35 S-methionine-labeled proteins synthesized by synovial cells and internal fibroblasts indicated that fibronectin was synthesized principally by synovial cells. Fibronectin at the tendon surface may play a role in cell attachment to prevent cell removal by the friction of gliding. Alternatively, fibronectin, with its binding sites for hyaluronic acid and collagen, may act as a complex for boundary lubrication

  15. Functional regeneration of ligament-bone interface using a triphasic silk-based graft.

    Science.gov (United States)

    Li, Hongguo; Fan, Jiabing; Sun, Liguo; Liu, Xincheng; Cheng, Pengzhen; Fan, Hongbin

    2016-11-01

    The biodegradable silk-based scaffold with unique mechanical property and biocompatibility represents a favorable ligamentous graft for tissue-engineering anterior cruciate ligament (ACL) reconstruction. However, the low efficiency of ligament-bone interface restoration barriers the isotropic silk graft to common ACL therapeutics. To enhance the regeneration of the silk-mediated interface, we developed a specialized stratification approach implementing a sequential modification on isotropic silk to constitute a triphasic silk-based graft in which three regions respectively referring to ligament, cartilage and bone layers of interface were divided, followed by respective biomaterial coating. Furthermore, three types of cells including bone marrow mesenchymal stem cells (BMSCs), chondrocytes and osteoblasts were respectively seeded on the ligament, cartilage and bone region of the triphasic silk graft, and the cell/scaffold complex was rolled up as a multilayered graft mimicking the stratified structure of native ligament-bone interface. In vitro, the trilineage cells loaded on the triphasic silk scaffold revealed a high proliferative capacity as well as enhanced differentiation ability into their corresponding cell lineage. 24 weeks postoperatively after the construct was implanted to repair the ACL defect in rabbit model, the silk-based ligamentous graft exhibited the enhancement of osseointegration detected by a robust pullout force and formation of three-layered structure along with conspicuously corresponding matrix deposition via micro-CT and histological analysis. These findings potentially broaden the application of silk-based ligamentous graft for ACL reconstruction and further large animal study. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. Clinical evaluation of bone- patellar tendon- bone grafts for anterior cruciate ligament injury

    International Nuclear Information System (INIS)

    Nakamura, Yasuhiro

    2011-01-01

    One thousand and thirty-eight cases of Anterior Cruciate Ligament (ACL) rupture were treated between January 2002 and November 2010. Eight hundred sixty-six cases (83.9%) were observed for at least six months. All cases were reconstructed with a bone to tendon to bone (BTB) graft from the patella. Much effort was made to return the patient to a competitive sports activity level within one year. The age at suffering from the initial injury ranged from 9 to 74 years old with a mean of 24.7 years old. There were 493 female (50.7%) and 427 male (49.3%) cases. The injured side was right in 408 cases and left in 458 cases. The mean postoperative observation period was 449.2 days. The number of patients who felt 80% or more certain that they could return to competitive sports activities was 538 (61.9%). From the MRI findings, continuity of the reconstructed graft was observed in 793 cases (98.5%). Arthroscopy after reconstruction was performed in 775 cases (89.5%). The reconstructed ACL was observed to be covered with an adequate synovium in 629 cases (81.2%). The medial meniscus and lateral meniscus showed no changes in 657 cases (84.8%) and 666 cases (85.9%) respectively. Reconstructions performed less than two weeks after injury showed no significant differences in terms of Range Of Motion (ROM), arthroscopic findings, or the number of patients who could return to competitive sports activities. Statistically significantly more patients who underwent their reconstruction at an age over forty experienced a loss motion of five degree in extension or ten degree in flexion and resumed a lower level of sports activities. Patients who underwent the reconstruction could return to exercises for muscle strengthening and ROMs within 2 weeks. Patients over forty years old who underwent their reconstruction could prevent their menisci from fraying, tearing, or undergoing osteoarthritic changes. (author)

  17. Molecular characterization and function of tenomodulin, a marker of tendons and ligaments that integrate musculoskeletal components

    Directory of Open Access Journals (Sweden)

    Chisa Shukunami, DDS, PhD

    2016-11-01

    Full Text Available Tendons and ligaments are dense fibrous bands of connective tissue that integrate musculoskeletal components in vertebrates. Tendons connect skeletal muscles to the bone and function as mechanical force transmitters, whereas ligaments bind adjacent bones together to stabilize joints and restrict unwanted joint movement. Fibroblasts residing in tendons and ligaments are called tenocytes and ligamentocytes, respectively. Tenomodulin (Tnmd is a type II transmembrane glycoprotein that is expressed at high levels in tenocytes and ligamentocytes, and is also present in periodontal ligament cells and tendon stem/progenitor cells. Tnmd is related to chondromodulin-1 (Chm1, a cartilage-derived angiogenesis inhibitor, and both Tnmd and Chm1 are expressed in the CD31− avascular mesenchyme. The conserved C-terminal hydrophobic domain of these proteins, which is characterized by the eight Cys residues to form four disulfide bonds, may have an anti-angiogenic function. This review highlights the molecular characterization and function of Tnmd, a specific marker of tendons and ligaments.

  18. Button fixation technique for Achilles tendon reinsertion: a biomechanical study.

    Science.gov (United States)

    Awogni, David; Chauvette, Guillaume; Lemieux, Marie-Line; Balg, Frédéric; Langelier, Ève; Allard, Jean-Pascal

    2014-01-01

    Chronic insertional tendinopathy of the Achilles tendon is a frequent and disabling pathologic entity. Operative treatment is indicated for patients for whom nonoperative management has failed. The treatment can consist of the complete detachment of the tendon insertion and extensive debridement. We biomechanically tested a new operative technique that uses buttons for fixation of the Achilles tendon insertion on the posterior calcaneal tuberosity and compared it with 2 standard bone anchor techniques. A total of 40 fresh-frozen cadaver specimens were used to compare 3 fixation techniques for reinserting the Achilles tendon: single row anchors, double row anchors, and buttons. The ultimate loads and failure mechanisms were recorded. The button assembly (median load 764 N, range 713 to 888) yielded a median fixation strength equal to 202% (range 137% to 251%) of that obtained with the double row anchors (median load 412 N, range 301 to 571) and 255% (range 213% to 317%) of that obtained with the single row anchors (median load 338 N, range 241 to 433N). The most common failure mechanisms were suture breakage with the buttons (55%) and pull out of the implant with the double row (70%) and single row (85%) anchors. The results of the present biomechanical cadaver study have shown that Achilles tendon reinsertion fixation using the button technique provides superior pull out strength than the bone anchors tested. Copyright © 2014 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  19. Bioactive Scaffolds for Regeneration of Cartilage and Subchondral Bone Interface

    Science.gov (United States)

    Deng, Cuijun; Zhu, Huiying; Li, Jiayi; Feng, Chun; Yao, Qingqiang; Wang, Liming; Chang, Jiang; Wu, Chengtie

    2018-01-01

    The cartilage lesion resulting from osteoarthritis (OA) always extends into subchondral bone. It is of great importance for simultaneous regeneration of two tissues of cartilage and subchondral bone. 3D-printed Sr5(PO4)2SiO4 (SPS) bioactive ceramic scaffolds may achieve the aim of regenerating both of cartilage and subchondral bone. We hypothesized that strontium (Sr) and silicon (Si) ions released from SPS scaffolds play a crucial role in osteochondral defect reconstruction. Methods: SPS bioactive ceramic scaffolds were fabricated by a 3D-printing method. The SEM and ICPAES were used to investigate the physicochemical properties of SPS scaffolds. The proliferation and maturation of rabbit chondrocytes stimulated by SPS bioactive ceramics were measured in vitro. The stimulatory effect of SPS scaffolds for cartilage and subchondral bone regeneration was investigated in vivo. Results: SPS scaffolds significantly stimulated chondrocyte proliferation, and SPS extracts distinctly enhanced the maturation of chondrocytes and preserved chondrocytes from OA. SPS scaffolds markedly promoted the regeneration of osteochondral defects. The complex interface microstructure between cartilage and subchondral bone was obviously reconstructed. The underlying mechanism may be related to Sr and Si ions stimulating cartilage regeneration by activating HIF pathway and promoting subchondral bone reconstruction through activating Wnt pathway, as well as preserving chondrocytes from OA via inducing autophagy and inhibiting hedgehog pathway. Conclusion: Our findings suggest that SPS scaffolds can help osteochondral defect reconstruction and well reconstruct the complex interface between cartilage and subchondral bone, which represents a promising strategy for osteochondral defect regeneration. PMID:29556366

  20. Impact of semiconductor/metal interfaces on contact resistance and operating speed of organic thin film transistors

    KAUST Repository

    Wondmagegn, Wudyalew T.

    2010-09-24

    The contact resistance of field effect transistors based on pentacene and parylene has been investigated by experimental and numerical analysis. The device simulation was performed using finite element two-dimensional drift-diffusion simulation taking into account field-dependent mobility, interface/bulk trap states and fixed charge density at the organic/insulator interface. The width-normalized contact resistance extracted from simulation which included an interface dipole layer between the gold source/drain electrodes and pentacene was 91 kΩcm. However, contact resistance extracted from the simulation, without consideration of interface dipole was 52.4 kΩcm, which is about half of the experimentally extracted 108 kΩcm. This indicates that interface dipoles are critical effects which degrade performances of organic field effect transistors by increasing the contact resistance. Using numerical calculations and circuit simulations, we have predicted a 1 MHz switching frequency for a 1 μm channel length transistor without dipole interface between gold and pentacene. The transistor with dipole interface is predicted, via the same methods, to exhibit an operating frequency of less than 0.5 MHz. © 2010 Springer Science+Business Media LLC.

  1. Impact of semiconductor/metal interfaces on contact resistance and operating speed of organic thin film transistors

    KAUST Repository

    Wondmagegn, Wudyalew T.; Satyala, Nikhil T.; Pieper, Ron J.; Quevedo-Ló pez, Manuel Angel Quevedo; Gowrisanker, Srinivas; Alshareef, Husam N.; Stiegler, Harvey J.; Gnade, Bruce E.

    2010-01-01

    The contact resistance of field effect transistors based on pentacene and parylene has been investigated by experimental and numerical analysis. The device simulation was performed using finite element two-dimensional drift-diffusion simulation taking into account field-dependent mobility, interface/bulk trap states and fixed charge density at the organic/insulator interface. The width-normalized contact resistance extracted from simulation which included an interface dipole layer between the gold source/drain electrodes and pentacene was 91 kΩcm. However, contact resistance extracted from the simulation, without consideration of interface dipole was 52.4 kΩcm, which is about half of the experimentally extracted 108 kΩcm. This indicates that interface dipoles are critical effects which degrade performances of organic field effect transistors by increasing the contact resistance. Using numerical calculations and circuit simulations, we have predicted a 1 MHz switching frequency for a 1 μm channel length transistor without dipole interface between gold and pentacene. The transistor with dipole interface is predicted, via the same methods, to exhibit an operating frequency of less than 0.5 MHz. © 2010 Springer Science+Business Media LLC.

  2. Lateral luxation of the superficial digital flexor tendon from the calcaneal tuber in two horses

    International Nuclear Information System (INIS)

    Meagher, D.M.; Aldrete, A.V.

    1989-01-01

    Lateral luxation of the superficial digital flexor tendon from the calcaneal tuber occurs in horses as a result of tearing or rupture of the medial retinaculum of the tendon. This report describes the repair of this condition in 2 Thoroughbred race horses, using a surgical technique in which 2 cancellous bone screws were placed in the calcaneus lateral to the tendon, along with suturing the medial retinaculum

  3. Does footprint preparation influence tendon-to-bone healing after rotator cuff repair in an animal model?

    Science.gov (United States)

    Ficklscherer, Andreas; Loitsch, Thomas; Serr, Michaela; Gülecyüz, Mehmet F; Niethammer, Thomas R; Müller, Hans-Helge; Milz, Stefan; Pietschmann, Matthias F; Müller, Peter E

    2014-02-01

    The aim of this study was to investigate the influence of footprint spongialization and radiofrequency ablation on rotator cuff repair outcomes compared with an untreated group in a rat model. We randomly assigned 189 Sprague-Dawley rats to either a spongialization, radiofrequency ablation, or untreated group. After separation of the supraspinatus tendon from the greater tubercle, the footprint was prepared by removing the cortical bone with a burr (spongialization), was prepared by ablating soft tissue with a radiofrequency ablation device, or was left unaltered (untreated). Biomechanical testing (after 7 weeks, n = 165) and histologic analysis after 1 and 7 weeks (n = 24) followed reinsertion. The mean load to failure was 17.51 ± 4.46 N/mm(2) in the spongialization group, 15.56 ± 4.85 N/mm(2) in the radiofrequency ablation group, and 19.21 ± 5.19 N/mm(2) in the untreated group. A significant difference was found between the spongialization and radiofrequency ablation groups (P = .0409), as well as between the untreated and radiofrequency ablation groups (P = .0014). There was no significant difference between the spongialization and untreated groups (P = .2456). The mean area of fibrocartilage transition, characterized by the presence of type II collagen, was larger after 1 and 7 weeks in the spongialization group (0.57 ± 0.1 mm(2) and 0.58 ± 0.1 mm(2), respectively) and untreated group (0.51 ± 0.1 mm(2) and 0.51 ± 0.2 mm(2), respectively) than in the radiofrequency ablation group (0.11 ± 0.1 mm(2) and 0.4 ± 0.1 mm(2), respectively) with P rotator cuff repair may influence tendon-to-bone healing. Copyright © 2014 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  4. A biomechanical and histological comparison of the suture bridge and conventional double-row techniques of the repair of full-thickness rotator cuff tears in a rabbit model.

    Science.gov (United States)

    Fei, Wenyong; Guo, Weichun

    2015-06-16

    The suture bridge (SB) technique and conventional double-row (DR) are both effective in repair of full-thickness rotator cuff tears . However, increasing numbers of scholars believe that the SB technique produces better results than conventional DR because of the higher bone-tendon contact area and pressure. However, The clinical outcomes have been mixed and little direct evidence has been supplied in vivo. This study was designed using the SB and DR techniques to determine which is the better technique. Sixty-four New Zealand white rabbits were randomly divided into 2 groups, the SB group and DR group. SB and DR were then used to repair their rotator cuff tears. Rabbits were then sacrificed at the 2(nd), 4(th), or 8(th) week after surgery and a histological comparison was made. The biomechanical comparison was made at the 8(th) week. The load to failure of the SB group was 134.59 ± 17.69 N at the 8(th) postoperative week, and that was significantly higher than in the DR group (103.83 ± 6.62, P = 0.001), but both repair groups remained lower than in the control group (199.25 ± 14.81). Histological evaluation showed that both the SB and DR groups healed at the bone-tendon interface. But there were subtle differences between the two groups in the structure and morphology of collagen fibers and cartilage cells at bone-tendon interface. In general, the collagen fibers of the SB group were more compact than those of the DR group at all times tested. At the 4(th) and 8(th) weeks, the collagen fibers and cartilage cells in the SB group were arranged in a column modality, but those in the DR group were distributed horizontally. The SB technique facilitated healing more effectively than the conventional DR technique. The difference in morphology of collagen fibers and cartilage cells may be related to the difference in bone-tendon contact pressure.

  5. [EFFECT OF RECOMBINANT ADENOVIRUS-BONE MORPHOGENETIC PROTEIN 12 TRANSFECTION ON DIFFERENTIATION OF PERIPHERAL BLOOD MESENCHYMAL STEM CELLS INTO TENDON/LIGAMENT CELLS].

    Science.gov (United States)

    Fu, Weili; Chen, Gang; Tang, Xin; Li, Qi; Ll, Jian

    2015-04-01

    To research the effect of recombinant adenovirus-bone morphogenetic protein 12 (Ad-BMP-12) transfection on the differentiation of peripheral blood mesenchymal stem cells (MSCs) into tendon/ligament cells. Peripheral blood MSCs were isolated from New Zealand rabbits (3-4 months old) and cultured in vitro until passage 3. The recombinant adenoviral vector system was prepared using AdEasy system, then transfected into MSCs at passage 3 (transfected group); untransfected MSCs served as control (untransfected group). The morphological characteristics and growth of transfected cells were observed under inverted phase contrast microscope. The transfection efficiency and green fluorescent protein (GFP) expression were detected by flow cytometry (FCM) and fluorescence microscopy. After cultured for 14 days in vitro, the expressions of tendon/ligament-specific markers were determined by immunohistochemistry and real-time fluorescent quantitative PCR. GFP expression could be observed in peripheral blood MSCs at 8 hours after transfection. At 24 hours after transfection, the cells had clear morphology and grew slowly under inverted phase contrast microscope and almost all expressed GFP at the same field under fluorescence microscopy. FCM analysis showed that the transfection efficiency of the transfected group was 99.57%, while it was 2.46% in the untransfected group. The immunohistochemistry showed that the expression of collagen type I gradually increased with culture time in vitro. Real-time fluorescent quantitative PCR results showed that the mRNA expressions of the tendon/ligament-specific genes (Tenomodulin, Tenascin-C, and Decorin) in the transfected group were significantly higher than those in untransfected group (0.061+/- 0.013 vs. 0.004 +/- 0.002, t = -7.700, P=0.031; 0.029 +/- 0.008 vs. 0.003 +/- 0.001, t = -5.741, P=0.020; 0.679 +/- 0.067 vs. 0.142 +/- 0.024, t = -12.998, P=0.000). Ad-BMP-12 can significantly promote differentiation of peripheral blood MSCs into

  6. High resolution X-ray imaging of bone-implant interface by large area flat-panel detector

    International Nuclear Information System (INIS)

    Kytyr, D; Jirousek, O; Dammer, J

    2011-01-01

    The aim of the research was to investigate the cemented bone-implant interface behavior (cement layer degradation and bone-cement interface debonding) with emphasis on imaging techniques suitable to detect the early defects in the cement layer. To simulate in vivo conditions a human pelvic bone was implanted with polyurethane acetabular cup using commercial acrylic bone cement. The implanted cup was then loaded in a custom hip simulator to initiate fatigue crack propagation in the bone cement. The pelvic bone was then repetitively scanned in a micro-tomography device. Reconstructed tomography images showed failure processes that occurred in the cement layer during the first 250,000 cycles. A failure in cemented acetabular implant - debonding, crumbling and smeared cracks - has been found to be at the bone-cement interface. Use of micro-focus source and high resolution flat panel detector of large physical dimensions allowed to reconstruct the micro-structural models suitable for investigation of migration, micro-motions and consecutive loosening of the implant. The large area flat panel detector with physical dimensions 120 x 120mm with 50μm pixel size provided a superior image quality compared to clinical CT systems with 300-150μm pixel size.

  7. Stability of double-row rotator cuff repair is not adversely affected by scaffold interposition between tendon and bone.

    Science.gov (United States)

    Beitzel, Knut; Chowaniec, David M; McCarthy, Mary Beth; Cote, Mark P; Russell, Ryan P; Obopilwe, Elifho; Imhoff, Andreas B; Arciero, Robert A; Mazzocca, Augustus D

    2012-05-01

    Rotator cuff reconstructions may be improved by adding growth factors, cells, or other biologic factors into the repair zone. This usually requires a biological carrier (scaffold) to be integrated into the construct and placed in the area of tendon-to-bone healing. This needs to be done without affecting the constructs mechanics. Hypothesis/ The hypothesis was that scaffold placement, as an interposition, has no adverse effects on biomechanical properties of double-row rotator cuff repair. The purpose of this study was to examine the effect of scaffold interposition on the initial strength of rotator cuff repairs. Controlled laboratory study. Twenty-five fresh-frozen shoulders (mean age: 65.5 ± 8.9 years) were randomly assigned to 5 groups. Groups were chosen to represent a broad spectrum of commonly used scaffold types: (1) double-row repair without augmentation, (2) double-row repair with interposition of a fibrin clot (Viscogel), (3) double-row repair with interposition of a collagen scaffold (Mucograft) between tendon and bone, (4) double-row repair with interposition of human dermis patch (ArthroFlex) between tendon and bone, and (5) double-row repair with human dermis patch (ArthroFlex) placed on top of the repair. Cyclic loading to measure displacement was performed to 3000 cycles at 1 Hz with an applied 10- to 100-N load. The ultimate load to failure was determined at a rate of 31 mm/min. There were no significant differences in mean displacement under cyclic loading, slope, or energy absorbed to failure between all groups (P = .128, P = .981, P = .105). Ultimate load to failure of repairs that used the collagen patch as an interposition (573.3 ± 75.6 N) and a dermis patch on top of the reconstruction (575.8 ± 22.6 N) was higher compared with the repair without a scaffold (348.9 ± 98.8 N; P = .018 and P = .025). No significant differences were found for repairs with the fibrin clot as an interposition (426.9 ± 103.6 N) and the decellularized dermis

  8. Tendon surveillance requirements - average tendon force

    International Nuclear Information System (INIS)

    Fulton, J.F.

    1982-01-01

    Proposed Rev. 3 to USNRC Reg. Guide 1.35 discusses the need for comparing, for individual tendons, the measured and predicted lift-off forces. Such a comparison is intended to detect any abnormal tendon force loss which might occur. Recognizing that there are uncertainties in the prediction of tendon losses, proposed Guide 1.35.1 has allowed specific tolerances on the fundamental losses. Thus, the lift-off force acceptance criteria for individual tendons appearing in Reg. Guide 1.35, Proposed Rev. 3, is stated relative to a lower bound predicted tendon force, which is obtained using the 'plus' tolerances on the fundamental losses. There is an additional acceptance criterion for the lift-off forces which is not specifically addressed in these two Reg. Guides; however, it is included in a proposed Subsection IWX to ASME Code Section XI. This criterion is based on the overriding requirement that the magnitude of prestress in the containment structure be sufficeint to meet the minimum prestress design requirements. This design requirement can be expressed as an average tendon force for each group of vertical hoop, or dome tendons. For the purpose of comparing the actual tendon forces with the required average tendon force, the lift-off forces measured for a sample of tendons within each group can be averaged to construct the average force for the entire group. However, the individual lift-off forces must be 'corrected' (normalized) prior to obtaining the sample average. This paper derives the correction factor to be used for this purpose. (orig./RW)

  9. [Reconstruction of chronic Achilles tendon rupture with flexor hallucis longus tendon harvested using a minimally invasive technique].

    Science.gov (United States)

    Miao, Xudong; Wu, Yongping; Tao, Huimin; Yang, Disheng

    2011-07-01

    To evaluate the effectiveness of flexor hallucis longus tendon harvested using a minimally invasive technique in reconstruction of chronic Achilles tendon rupture. Between July 2006 and December 2009, 22 patients (22 feet) with chronic Achilles tendon rupture were treated, including 16 males and 6 females with a median age of 48 years (range, 28-65 years). The disease duration was 27-1,025 days (median, 51 days). Twenty-one patients had hooflike movement's history and 1 patient had no obvious inducement. The result of Thompson test was positive in 22 cases. The score was 53.04 +/- 6.75 according to American Orthopedic Foot and Ankle Society (AOFAS) ankle and hindfoot score system. MRI indicated that the gap of the chronic Achilles tendon rupture was 4.2-8.0 cm. A 3 cm-long incision was made vertically in the plantar aspect of the midfoot and a 1 cm-long transverse incision was made in a plantar flexor crease at the base of the great toe to harvest flexor hallucis longus tendon. The flexor hallucis longus tendon was 10.5-13.5 cm longer from tuber calcanei to the end of the Achilles tendon, and then the tendon was fixed to the tuber calcanei using interface screws or anchor nail after they were woven to form reflexed 3-bundle and sutured. Wound healed by first intention in all patients and no early complication occurred. Twenty-two patients were followed up 12-42 months (mean, 16.7 months). At 12 months after operation, The AOFAS ankle and hindfoot score was 92.98 +/- 5.72, showing significant difference when compared with that before operation (t= -40.903, P=0.000). The results were excellent in 18 cases, good in 2 cases, and fair in 2 cases with an excellent and good rate of 90.9%. No sural nerve injury, posterior tibial nerve injury, plantar painful scar, medial plantar nerve injury, and lateral plantar nerve injury occurred. Chronic Achilles tendon rupture reconstruction with flexor hallucis longus tendon harvested using a minimally invasive technique offers a

  10. Contact resistance at ceramic interfaces and its dependence on mechanical load

    DEFF Research Database (Denmark)

    Koch, Søren; Hendriksen, P.V.

    2004-01-01

    Low contact resistance between individual components is important for solid oxide fuel cell stacks if high performance is to be achieved. Several mechanisms may result in high contact resistance, e.g., current constriction due to low area of contact and formation of resistive phases between...... the components. In this study, the importance of current constriction due to limited area of contact at an interface is investigated by comparing the characteristics of contacts between LSM pellets with different surface finish. The load behaviour of the contact resistance has been investigated and a power law...... of the contact resistance was calculated using a simple model describing the variation of the contact area with load based on the measured surface roughness. Good agreement between the calculations and the experimentally observed resistances was found. (C) 2004 Elsevier B.V. All rights reserved....

  11. Extracellular matrix adaptation of tendon and skeletal muscle to exercise

    DEFF Research Database (Denmark)

    Kjaer, Michael; Magnusson, Peter; Krogsgaard, Michael

    2006-01-01

    The extracellular matrix (ECM) of connective tissues enables linking to other tissues, and plays a key role in force transmission and tissue structure maintenance in tendons, ligaments, bone and muscle. ECM turnover is influenced by physical activity, and both collagen synthesis and metalloprotease......-beta and IL-6 is enhanced following exercise. For tendons, metabolic activity (e.g. detected by positron emission tomography scanning), circulatory responses (e.g. as measured by near-infrared spectroscopy and dye dilution) and collagen turnover are markedly increased after exercise. Tendon blood flow...... is regulated by cyclooxygenase-2 (COX-2)-mediated pathways, and glucose uptake is regulated by specific pathways in tendons that differ from those in skeletal muscle. Chronic loading in the form of physical training leads both to increased collagen turnover as well as to some degree of net collagen synthesis...

  12. Study of Direct-Contact HfO2/Si Interfaces

    Directory of Open Access Journals (Sweden)

    Noriyuki Miyata

    2012-03-01

    Full Text Available Controlling monolayer Si oxide at the HfO2/Si interface is a challenging issue in scaling the equivalent oxide thickness of HfO2/Si gate stack structures. A concept that the author proposes to control the Si oxide interface by using ultra-high vacuum electron-beam HfO2 deposition is described in this review paper, which enables the so-called direct-contact HfO2/Si structures to be prepared. The electrical characteristics of the HfO2/Si metal-oxide-semiconductor capacitors are reviewed, which suggest a sufficiently low interface state density for the operation of metal-oxide-semiconductor field-effect-transistors (MOSFETs but reveal the formation of an unexpected strong interface dipole. Kelvin probe measurements of the HfO2/Si structures provide obvious evidence for the formation of dipoles at the HfO2/Si interfaces. The author proposes that one-monolayer Si-O bonds at the HfO2/Si interface naturally lead to a large potential difference, mainly due to the large dielectric constant of the HfO2. Dipole scattering is demonstrated to not be a major concern in the channel mobility of MOSFETs.

  13. Generalization of proposed tendon friction correlation and its application to PCCV structural analysis

    International Nuclear Information System (INIS)

    Kashiwase, Takako; Nagasaka, Hideo

    2000-01-01

    The present paper dealt with the extension of tendon friction coefficient correlation as a function of loading end load and circumferential angle, proposed in the former paper. The extended correlation further included the effects of the number of strands contacted with sheath, tendon diameter, politicization of tendon and tendon local curvature. The validity of the correlation was confirmed by several published measured data. The structural analysis of middle cylinder part of 1/4 PCCV (Prestressed Concrete Containment Vessel) model was conducted using the present friction coefficient correlation. The results were compared with the analysis using constant friction coefficient, focused on the tendon tension force distribution. (author)

  14. Measurement of stress strain and vibrational properties of tendons

    Science.gov (United States)

    Revel, Gian Marco; Scalise, Alessandro; Scalise, Lorenzo

    2003-08-01

    The authors present a new non-intrusive experimental procedure based on laser techniques for the measurement of mechanical properties of tendons. The procedure is based on the measurement of the first resonance frequency of the tendon by laser Doppler vibrometry during in vitro tensile experiments, with the final aim of establishing a measurement procedure to perform the mechanical characterization of tendons by extracting parameters such as the resonance frequency, also achievable during in vivo investigation. The experimental procedure is reported, taking into account the need to simulate the physiological conditions of the Achilles tendon, and the measurement technique used for the non-invasive determination of tendon cross-sectional area during tensile vibration tests at different load levels is described. The test procedure is based on a tensile machine, which measures longitudinal tendons undergoing controlled load conditions. Cross-sectional area is measured using a new non-contact procedure for the measurement of tendon perimeter (repeatability of 99% and accuracy of 2%). For each loading condition, vibration resonance frequency and damping, cross-sectional area and tensile force are measured, allowing thus a mechanical characterization of the tendon. Tendon stress-strain curves are reported. Stress-strain curves have been correlated to the first vibration resonance frequency and damping of the tendon measured using a single-point laser Doppler vibrometer. Moreover, experimental results have been compared with a theoretical model of a vibrating cord showing discrepancies. In vitro tests are reported, demonstrating the validity of the method for the comparison of different aged rabbit tendons.

  15. Compositional studies at the Bone-Cartilage interface using PIXE, RBS and cSAXS techniques

    International Nuclear Information System (INIS)

    Kaabar, W.; Gundogdu, O.; Bradley, D.A.; Bunk, O.; Pfeiffer, F.; Pfeiffer, F.; Farquharson, M.J.; Webb, M.; Jeynes, C.

    2009-01-01

    Micro Proton Induced X-ray Emission (μ-PIXE) analysis has been employed herein in investigating and quantifying the distribution of a number of essential cations in two thin slices of normal and diseased human articular cartilage, the latter being affected by osteoarthritis (OA). The elemental distribution maps for Ca, P, K, S and Zn in the normal and diseased slices showed similar patterns with marked increases in elemental concentrations in the bone-cartilage interface. The S concentration was significantly lower in bone than in cartilage. Conversely, the Ca and P concentrations were higher in bone. The Ca/P ratio (2.22) of the diseased slice was determined by employing the Rutherford backscattering technique (RBS). The RBS figures of this investigation agree with values previously reported by others. Structural and organisational changes of collagen networks were investigated by coherent Small-Angle X-ray Scattering (SAXS) using beamline facilities at the Swiss Light Source (SLS) for a decalcified diseased human articular cartilage slice. The SAXS findings showed a gradual reorientation of collagen type II fibres of cartilage from parallel to the surface of the joint to normal to the bone-cartilage interface. Similar patterns of orientation were observed at the subchondral bone to bone-cartilage interface

  16. Micro-mechanical modeling of the cement-bone interface: the effect of friction, morphology and material properties on the micromechanical response.

    Science.gov (United States)

    Janssen, Dennis; Mann, Kenneth A; Verdonschot, Nico

    2008-11-14

    In order to gain insight into the micro-mechanical behavior of the cement-bone interface, the effect of parametric variations of frictional, morphological and material properties on the mechanical response of the cement-bone interface were analyzed using a finite element approach. Finite element models of a cement-bone interface specimen were created from micro-computed tomography data of a physical specimen that was sectioned from an in vitro cemented total hip arthroplasty. In five models the friction coefficient was varied (mu=0.0; 0.3; 0.7; 1.0 and 3.0), while in one model an ideally bonded interface was assumed. In two models cement interface gaps and an optimal cement penetration were simulated. Finally, the effect of bone cement stiffness variations was simulated (2.0 and 2.5 GPa, relative to the default 3.0 GPa). All models were loaded for a cycle of fully reversible tension-compression. From the simulated stress-displacement curves the interface deformation, stiffness and hysteresis were calculated. The results indicate that in the current model the mechanical properties of the cement-bone interface were caused by frictional phenomena at the shape-closed interlock rather than by adhesive properties of the cement. Our findings furthermore show that in our model maximizing cement penetration improved the micromechanical response of the cement-bone interface stiffness, while interface gaps had a detrimental effect. Relative to the frictional and morphological variations, variations in the cement stiffness had only a modest effect on the micro-mechanical behavior of the cement-bone interface. The current study provides information that may help to better understand the load-transfer mechanisms taking place at the cement-bone interface.

  17. Fibril deformation under load of the rabbit Achilles tendon and medial collateral ligament femoral entheses.

    Science.gov (United States)

    Sevick, Johnathan L; Abusara, Ziad; Andrews, Stephen H; Xu, Minjia; Khurshid, Saad; Chatha, Jansher; Hart, David A; Shrive, Nigel G

    2018-04-10

    Microscopic visualization under load of the region connecting ligaments/tendons to bone, the enthesis, has been performed previously; however, specific investigation of individual fibril deformation may add insight to such studies. Detailed visualization of fibril deformation would inform on the mechanical strategies employed by this tissue in connecting two mechanically disparate materials. Clinically, an improved understanding of enthesis mechanics may help guide future restorative efforts for torn or injured ligaments/tendons, where the enthesis is often a point of weakness. In this study, a custom ligament/tendon enthesis loading device was designed and built, a unique method of sample preparation was devised, and second harmonic and two-photon fluorescence microscopy were used to capture the fibril-level load response of the rabbit Achilles tendon and medial collateral ligament femoral entheses. A focus was given to investigation of the mechanical problem of fibril embedment. Resultant images indicate a rapid (occurring over approximately 60 μm) change in fibril orientation at the interface of ligament/tendon and calcified fibrocartilage early in the loading regime, before becoming relatively constant. Such a change in fibril angle helps confirm the materially graded region demonstrated by others, while, in this case, providing additional insight into fibril bending. We speculate that the scale of the mechanical problem (i.e., fibril diameters being on the order of 250 nm) allows fibrils to bend over the small (relative to the imaging field of view, but large relative to fibril diameter) distances observed; thus, potentially lessening required embedment lengths. Nevertheless, this behavior merits further investigation to be confirmed. © 2018 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res. © 2018 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  18. Engaging Stem Cells for Customized Tendon Regeneration

    Directory of Open Access Journals (Sweden)

    Hatim Thaker

    2012-01-01

    Full Text Available The need for a consistent therapeutic approach to tendon injury repair is long overdue. Patients with tendon microtears or full ruptures are eligible for a wide range of invasive and non invasive interventions, often subjectively decided by the physician. Surgery produces the best outcomes, and while studies have been conducted to optimize graft constructs and to track outcomes, the data from these studies have been inconclusive on the whole. What has been established is a clear understanding of healthy tendon architecture and the inherent process of healing. With this knowledge, tissue regeneration efforts have achieved immense progress in scaffold design, cell line selection, and, more recently, the appropriate use of cytokines and growth factors. This paper evaluates the plasticity of bone-marrow-derived stem cells and the elasticity of recently developed biomaterials towards tendon regeneration efforts. Mesenchymal stem cells (MSCs, hematopoietic progenitor cells, and poly(1,8-octanediol co-citrate scaffolds (POC are discussed in the context of established grafting strategies. With POC scaffolds to cradle the growth of MSCs and hematopoietic progenitor cells, developing a fibroelastic network guided by cytokines and growth factors may contribute towards consistent graft constructs, enhanced functionality, and better patient outcomes.

  19. Tuning back contact property via artificial interface dipoles in Si/organic hybrid solar cells

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Dan [Ningbo Institute of Materials Technology and Engineering, Chinese Academy of Sciences, Ningbo 315201 (China); Department of Physics and Institute of Solid-state electronics physical, Ningbo University, Ningbo 315211 (China); Sheng, Jiang, E-mail: shengjiang@nimte.ac.cn; Wu, Sudong; Zhu, Juye; Chen, Shaojie; Gao, Pingqi; Ye, Jichun, E-mail: jichun.ye@nimte.ac.cn [Ningbo Institute of Materials Technology and Engineering, Chinese Academy of Sciences, Ningbo 315201 (China)

    2016-07-25

    Back contact property plays a key role in the charge collection efficiency of c-Si/poly(3,4-ethylthiophene):poly(styrenesulfonate) hybrid solar cells (Si-HSCs), as an alternative for the high-efficiency and low-cost photovoltaic devices. In this letter, we utilize the water soluble poly (ethylene oxide) (PEO) to modify the Al/Si interface to be an Ohmic contact via interface dipole tuning, decreasing the work function of the Al film. This Ohmic contact improves the electron collection efficiency of the rear electrode, increasing the short circuit current density (J{sub sc}). Furthermore, the interface dipoles make the band bending downward to increase the total barrier height of built-in electric field of the solar cell, enhancing the open circuit voltage (V{sub oc}). The PEO solar cell exhibits an excellent performance, 12.29% power conversion efficiency, a 25.28% increase from the reference solar cell without a PEO interlayer. The simple and water soluble method as a promising alternative is used to develop the interfacial contact quality of the rear electrode for the high photovoltaic performance of Si-HSCs.

  20. On the Modeling of Contact Interfaces with Frictional Slips

    Directory of Open Access Journals (Sweden)

    Ligia Munteanu

    2013-09-01

    Full Text Available The paper analyses the contact interfaces between the scatterers and the matrix into the sonic composites, in the presence of the frictional slips. The sonic composite is a sonic liner designed in order to provide suppression of unwanted noise for jet engines, with emphases on the nacelle of turbofan engines for commercial aircraft.

  1. Integration of the Residual Limb with Prostheses via Direct Skin-Bone-Peripheral Nerve Interface

    Science.gov (United States)

    2017-10-01

    AWARD NUMBER: W81XWH-16-1-0791 TITLE: Integration of the Residual Limb with Prostheses via Direct Skin- Bone-Peripheral Nerve Interface...ABOVE ADDRESS. 1. REPORT DATE October 2017 2. REPORT TYPE Annual 3. DATES COVERED 30 Sep 2016 - 29 Sep 2017 4. TITLE AND SUBTITLE Integration of the...translational study to develop Skin and Bone Integrated Pylon with Peripheral Neural Interface (SBIP-PNI) directly attached to the residuum and the

  2. Tendons in the plantar aspect of the foot: MR imaging and anatomic correlation in cadavers

    Energy Technology Data Exchange (ETDEWEB)

    Fernandes, Rodrigo [University of California San Diego, Radiology, San Diego, CA (United States); Fleury Medical Center, Radiology, Sao Paulo, SP (Brazil); Aguiar, Rodrigo; Trudell, Debra; Resnick, Donald [University of California San Diego, Radiology, San Diego, CA (United States)

    2007-02-15

    The purpose of this anatomic imaging study was to illustrate the normal complex anatomy of tendons of the plantar aspect of the ankle and foot using magnetic resonance (MR) imaging with anatomic correlation in cadavers. Seven fresh cadaveric feet (obtained and used according to institutional guidelines, with informed consent from relatives of the deceased) were studied with intermediate-weighted fast-spin-echo MR imaging. For anatomic analysis, cadaveric specimens were sectioned in 3-mm-thick slices in the coronal and axial planes that approximated the sections acquired at MR imaging. The entire courses of the tendons into the plantar aspect of the foot were analyzed. The tibialis posterior tendon has a complex distal insertion. The insertions in the navicular, second, and third cuneiforms bones were identify in all cases using axial and coronal planes. A tendinous connection between the flexor hallucis longus and the flexor digitorum longus tendons was identified in five of our specimens (71%). The coronal plane provided the best evaluation. The peroneus longus tendon changes its direction at three points then obliquely crosses the sole and inserts in the base of the first metatarsal bone and the plantar aspect of the first cuneiform. MR imaging provides detailed information about the anatomy of tendons in the plantar aspect of the ankle and foot. It allows analysis of their insertions and the intertendinous connection between the flexor hallucis longus and the flexor digitorum longus tendons. (orig.)

  3. Osteomyelitis of the proximal sesamoid bone in a horse - a case report

    International Nuclear Information System (INIS)

    Kofler, J.

    1994-01-01

    Suppurative osteomyelitis of the lateral proximal sesamoid bone and chronic septic tenosynovitis of the digital flexor tendon sheath of the right hind limb was diagnosed in a 8 year old warmblood mare. Three months earlier the horse had received a puncture wound in the plantar fetlock region, penetrating the plantar annular ligament, tendon sheath and intersesamoidian ligament up to the plantaro-axial surface of the lateral sesamoid bone. The clinical, radiographic and ultrasonographic findings are described. The horse showed grade 2 / 4 right hindlimb lameness, marked thickening of the entire digital flexor tendon sheath area as well as the puncture wound in the middle of the annular ligament region. Radiographs revealed a 10 x 12 mm centro-axial, circular translucent lesion and marked bony proliferation on the abaxial and plantar margins of the lateral proximal sesamoid. Adhesions and marked anechoic areas between the plantar septum of the tendon sheath and the superficial flexor tendon, a thickening of the plantar annular ligament and structural alterations of the deep flexor tendon were demonstrated by sonography. Due to these severe findings a very poor prognosis was given and therefore surgery was not recommended. The horse was euthanized 4 months later as a result of further deterioration. Additional clinical, radiographic and sonographic findings as well as post mortem findings are mentioned. Gross pathology showed a fibrino-purulent tenosynovitis of the digital flexor tendon sheath and tendinitis of both flexor tendons, as well as a fistulous lesion of the intersesamoidian ligament over the lateral proximal sesamoid bone. The patho-histologic examination revealed focal suppurative osteomyelitis of the lateral sesamoid bone with necrotic bone tissue in the osteolytic area and accumulated neutrophils and macrophages [de

  4. Modelling of the Contact Condition at the Tool/Matrix Interface in Friction Stir Welding

    DEFF Research Database (Denmark)

    Schmidt, Henrik Nikolaj Blich; Hattel, Jesper; Wert, John

    2003-01-01

    a known contact condition at the contact interface, e.g. either as pure sliding or sticking. The present model uses Coulomb’s law of friction for the sliding condition and the material yield shear stress for the sticking condition to model the contact forces. The model includes heat generation...

  5. Time domain optical coherence tomography investigation of bone matrix interface in rat femurs

    Science.gov (United States)

    Rusu, Laura-Cristina; Negruá¹±iu, Meda-Lavinia; Sinescu, Cosmin; Hoinoiu, Bogdan; Topala, Florin-Ionel; Duma, Virgil-Florin; Rominu, Mihai; Podoleanu, Adrian G.

    2013-08-01

    The materials used to fabricate scaffolds for tissue engineering are derived from synthetic polymers, mainly from the polyester family, or from natural materials (e.g., collagen and chitosan). The mechanical properties and the structural properties of these materials can be tailored by adjusting the molecular weight, the crystalline state, and the ratio of monomers in the copolymers. Quality control and adjustment of the scaffold manufacturing process are essential to achieve high standard scaffolds. Most scaffolds are made from highly crystalline polymers, which inevitably result in their opaque appearance. Their 3-D opaque structure prevents the observation of internal uneven surface structures of the scaffolds under normal optical instruments, such as the traditional light microscope. The inability to easily monitor the inner structure of scaffolds as well as the interface with the old bone poses a major challenge for tissue engineering: it impedes the precise control and adjustment of the parameters that affect the cell growth in response to various mimicked culture conditions. The aim of this paper is to investigate the interface between the femur rat bone and the new bone that is obtained using a method of tissue engineering that is based on different artificial matrixes inserted in previously artificially induced defects. For this study, 15 rats were used in conformity with ethical procedures. In all the femurs a round defect was induced by drilling with a 1 mm spherical Co-Cr surgical drill. The matrixes used were Bioss and 4bone. These materials were inserted into the induced defects. The femurs were investigated at 1 week, 1 month, 2 month and three month after the surgical procedures. The interfaces were examined using Time Domain (TD) Optical Coherence Tomography (OCT) combined with Confocal Microscopy (CM). The optical configuration uses two single mode directional couplers with a superluminiscent diode as the source centered at 1300 nm. The scanning

  6. Iliopsoas Tendon Reformation after Psoas Tendon Release

    Directory of Open Access Journals (Sweden)

    K. Garala

    2013-01-01

    Full Text Available Internal snapping hip syndrome, or psoas tendonitis, is a recognised cause of nonarthritic hip pain. The majority of patients are treated conservatively; however, occasionally patients require surgical intervention. The two surgical options for iliopsoas tendinopathy are step lengthening of the iliopsoas tendon or releasing the tendon at the lesser trochanter. Although unusual, refractory snapping usually occurs soon after tenotomy. We report a case of a 47-year-old active female with internal snapping and pain following an open psoas tenotomy. Postoperatively she was symptom free for 13 years. An MRI arthrogram revealed reformation of a pseudo iliopsoas tendon reinserting into the lesser trochanter. The pain and snapping resolved after repeat iliopsoas tendon release. Reformation of tendons is an uncommon sequela of tenotomies. However the lack of long-term studies makes it difficult to calculate prevalence rates. Tendon reformation should be included in the differential diagnosis of failed tenotomy procedures after a period of symptom relief.

  7. Investigation of force, contact area, and dwell time in finger-tapping tasks on membrane touch interface.

    Science.gov (United States)

    Liu, Na; Yu, Ruifeng

    2018-06-01

    This study aimed to determine the touch characteristics during tapping tasks on membrane touch interface and investigate the effects of posture and gender on touch characteristics variables. One hundred participants tapped digits displayed on a membrane touch interface on sitting and standing positions using all fingers of the dominant hand. Touch characteristics measures included average force, contact area, and dwell time. Across fingers and postures, males exerted larger force and contact area than females, but similar dwell time. Across genders and postures, thumb exerted the largest force and the force of the other four fingers showed no significant difference. The contact area of the thumb was the largest, whereas that of the little finger was the smallest; the dwell time of the thumb was the longest, whereas that of the middle finger was the shortest. Relationships among finger sizes, gender, posture and touch characteristics were proposed. The findings helped direct membrane touch interface design for digital and numerical control products from hardware and software perspectives. Practitioner Summary: This study measured force, contact area, and dwell time in tapping tasks on membrane touch interface and examined effects of gender and posture on force, contact area, and dwell time. The findings will direct membrane touch interface design for digital and numerical control products from hardware and software perspectives.

  8. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... views of bone, they provide little information about muscles, tendons or joints. An MRI may be more useful in identifying bone and joint injuries (e.g., meniscal and ligament tears in the knee, rotator cuff and labrum tears ...

  9. Osseointegration Of Implants In Rabbit Bone With A Low Calcium Diet And Irradiation

    International Nuclear Information System (INIS)

    Kim, So Jung; Hwang, Eui Hwan; Lee, Sang Rae

    2000-01-01

    To investigate osseointergration of titanium implants into the tibia of rabbits, which were fed a low calcium diet and irradiated. To prepare the experimental model, control group was fed a normal diet and experimental group was fed a low calcium diet for 4 weeks. And then, titanium implants were inserted into the tibia of each rabbit. Experimental group was subdivided into two groups; low calcium diet/non-irradiation group and low calcium diet/irradiation group. The low calcium diet/irradiation group was irradiated with a single absorbed dose of 15 Gy at the 5th postoperative days. On the 12th, 19th, 33rd, 47th, and 61st days after implantation(1, 2, 4, 6, and 8 weeks after irradiation), the bone formation in the bone-implant interface area was examined by light microscopy and fluorescent microscopy. 1. In the control group, there began to form woven bone in the bone-implant interface area on the 12th days after implantation. As the experimental time was going on, the amount of bone which was in contact with the implant was increased. 2. In the low calcium diet/non-irradiation group, there began to form woven bone in the bone-implant interface area on the 19th days after implantation. Although the amount of bone which was in contact with the implant was increased as the experimental time was going on, the extent of increased bone was slightly weak as compared with control group. 3. In the low calcium diet/irradiation group, there began to form woven bone incompletely in the bone-implant interface area on the 19th days after implantation, but there were vascular connective tissues in the bone- implant interface area over the entire experimental period. 4. In the control group and low calcium diet/non-irradiation group, bone labeling bands were observed on the 33rd days after implantation, which suggests that the bone formation and remodeling was in process, but interstitial bone remodeling was not observed in the low calcium diet/irradiation group.

  10. Suture anchor tenodesis in repair of distal Achilles tendon injuries.

    Science.gov (United States)

    Kiliçoğlu, Onder; Türker, Mehmet; Yildız, Fatih; Akalan, Ekin; Temelli, Yener

    2014-01-01

    Distal Achilles tendon avulsions are in the form of either bony and nonbony avulsion of Achilles tendon from its calcaneal insertion. Four patients with distal Achilles tendon avulsions or ruptures which were treated with tendon to bone repair using suture anchors are presented here. Operated leg was immobilized in above-knee cast for 4 weeks while the patient walked non-weight-bearing. Then, cast was changed to below knee, and full weight-bearing was allowed. Patients underwent gait analysis minimum at first postoperative year. Mean American Orthopedics Foot Ankle Society ankle/hindfoot score of patients at last visit was 88.75 (range 85-100), and Achilles tendon total rupture score was 77.75 (range 58-87). Mean passive dorsiflexion of injured ankles (14° ± 5°) was lower than uninjured ankles (23° ± 9°). All the kinematic parameters of gait analysis were comparable to the uninjured side. Maximum plantar flexion power of injured ankle was 1.40 W/kg, and this was significantly lower than the contralateral side value 2.38 W/kg; (P = 0.0143). There were no visually altered gait or problems in daily life. Suture anchor tenodesis technique of distal Achilles tendon avulsions was successful in achieving durable osteotendinous repairs.

  11. The roles of TGF-beta1 gene transfer on collagen formation during Achilles tendon healing.

    Science.gov (United States)

    Hou, Yu; Mao, ZeBing; Wei, XueLei; Lin, Lin; Chen, LianXu; Wang, HaiJun; Fu, Xin; Zhang, JiYing; Yu, ChangLong

    2009-05-29

    Collagen content and cross-linking are believed to be major determinants of tendon structural integrity and function. The current study aimed to investigate the effects of transforming growth factor (TGF)-beta1 on the collagen content and cross-linking of Achilles tendons, and on the histological and biomechanical changes occurring during Achilles tendon healing in rabbits. Bone marrow-derived mesenchymal stem cells (BMSCs) transfected with the TGF-beta1 gene were surgically implanted into experimentally injured Achilles tendons. Collagen proteins were identified by immunohistochemical staining and fiber bundle accumulation was revealed by Sirius red staining. Achilles tendons treated with TGF-beta1-transfected BMSCs showed higher concentrations of collagen I protein, more rapid matrix remodeling, and larger fiber bundles. Thus TGF-beta1 can promote mechanical strength in healing Achilles tendons by regulating collagen synthesis, cross-link formation, and matrix remodeling.

  12. Pentadecapeptide BPC 157 Enhances the Growth Hormone Receptor Expression in Tendon Fibroblasts

    Directory of Open Access Journals (Sweden)

    Chung-Hsun Chang

    2014-11-01

    Full Text Available BPC 157, a pentadecapeptide derived from human gastric juice, has been demonstrated to promote the healing of different tissues, including skin, muscle, bone, ligament and tendon in many animal studies. However, the underlying mechanism has not been fully clarified. The present study aimed to explore the effect of BPC 157 on tendon fibroblasts isolated from Achilles tendon of male Sprague-Dawley rat. From the result of cDNA microarray analysis, growth hormone receptor was revealed as one of the most abundantly up-regulated genes in tendon fibroblasts by BPC 157. BPC 157 dose- and time-dependently increased the expression of growth hormone receptor in tendon fibroblasts at both the mRNA and protein levels as measured by RT/real-time PCR and Western blot, respectively. The addition of growth hormone to BPC 157-treated tendon fibroblasts dose- and time-dependently increased the cell proliferation as determined by MTT assay and PCNA expression by RT/real-time PCR. Janus kinase 2, the downstream signal pathway of growth hormone receptor, was activated time-dependently by stimulating the BPC 157-treated tendon fibroblasts with growth hormone. In conclusion, the BPC 157-induced increase of growth hormone receptor in tendon fibroblasts may potentiate the proliferation-promoting effect of growth hormone and contribute to the healing of tendon.

  13. Normal tendon sheath of the second to fifth fingers as seen on oblique views

    Energy Technology Data Exchange (ETDEWEB)

    Fischer, E.

    1984-01-01

    Oblique views of the fingers, using a low kilovolt technique, show a portion of the tendon sheaths which can be regarded as representative of the entire sheath. Because of the varying obliquity of each finger, this proportion differs in the fingers. With increasing age the projected portion of the sheath becomes smaller because it is covered by increasing bone formation in the insertion of the tendon sheat. Normal values have been obtained for adults according to their decades; from these, quite minor degrees of tendon sheat thickening can be determined. In camptodactyly of the fifth finger, which is not uncommon, the tendon sheat may be widened in the absence of a tenosynovitis.

  14. Texture analyses of Sauropod dinosaur bones from Tendaguru

    International Nuclear Information System (INIS)

    Pyzalla, A.R.; Sander, P.M.; Hansen, A.; Ferreyro, R.; Yi, S.-B.; Stempniewicz, M.; Brokmeier, H.-G.

    2006-01-01

    The apatite texture of fossil Brachiosaurus brancai and Barosaurus africanus sauropod bones from the excavation site at Tendaguru, Tanzania, was characterized by neutron diffraction pole figures. The results obtained reveal predominantly -fibre textures of the apatite; the fibre direction coincides with the longitudinal direction of the long bones of the skeletons. Neutron pole figures further indicate that other texture types may also be present. Texture strength is similar to dinosaur tendons and contemporary turkey tendon studied by others. Variations of texture strength across the bone wall cross-sections are not significantly large

  15. Micromechanical modeling of the cement-bone interface: the effect of friction, morphology and material properties on the micromechanical response

    OpenAIRE

    Janssen, Dennis; Mann, Kenneth A.; Verdonschot, Nico

    2008-01-01

    In order to gain insight into the micro-mechanical behavior of the cement-bone interface, the effect of parametric variations of frictional, morphological and material properties on the mechanical response of the cement-bone interface were analyzed using a finite element approach. Finite element models of a cement-bone interface specimen were created from micro-computed tomography data of a physical specimen that was sectioned from an in vitro cemented total hip arthroplasty. In five models t...

  16. Bone--bone marrow interface (endosteum) potential relationship of microenvironments in the regulation of response to internal emitters

    International Nuclear Information System (INIS)

    Wilson, F.D.; Pool, R.R.; Stitzel, K.; Momeni, M.H.

    1976-01-01

    The interface between bone and bone marrow is examined in relation to radiation effects, with attention to new concepts of hematopoiesis. Such concepts propose a functional role of stroma in regulating the commitment of pluripotent stem cells as well as in the production of colony stimulating activity (CSA) including candidate granulopoietin(s). Morphologic examples are included, underlining the concept that stroma (including bone) and hematopoietic elements respond as a functional unit to injury to marrow elements. The methylcellulose bone marrow culture system is reviewed as it may relate to a method for quantitation of hematopoietic colonies (CFU-C), humoral regulators for granulopoiesis (CSA), and potentially as a method of quantitating mesenchymal progenitor populations (PFU-C). Based on these and other observations cited, a model depicting a tentative positioning of cells at risk relative to bone-seeking radionuclides is presented

  17. Tubercular tenosynovitis of extensor tendons of foot--a rare ...

    African Journals Online (AJOL)

    Tuberculosis of soft tissues as a result of spread from adjacent bone or joint is a well recognized entity. However isolated tuberculous pyomyositis, bursitis and tenosynovitis are rare, constituting about 1% of skeletal tuberculosis. Tubercular tenosynovitis commonly involves tendon sheaths of wrist and hand. Cases of ...

  18. A retrospective review of bone tunnel enlargement after anterior cruciate ligament reconstruction with hamstring tendons fixed with a metal round cannulated interference screw in the femur.

    Science.gov (United States)

    Kobayashi, Masahiko; Nakagawa, Yasuaki; Suzuki, Takashi; Okudaira, Shuzo; Nakamura, Takashi

    2006-10-01

    To assess bone tunnel enlargement after anterior cruciate ligament (ACL) reconstruction with the use of hamstring tendons fixed with a round cannulated interference (RCI) screw in the femur. A consecutive series of 30 ACL reconstructions performed with hamstring tendons fixed with an RCI screw in the femur and with staples via Leeds-Keio ligament in the tibia was retrospectively reviewed. The clinical outcome was evaluated through the Lysholm score. Anterior instability was tested by Telos-SE (Telos Japan, Tokyo, Japan) measurement. The location and angle of each femoral and tibial tunnel were measured with the use of plain radiographs, and bone tunnel enlargement greater than 2 mm detected any time 3, 6, 12, and 24 months postoperatively was defined as positive. Each factor (location and angle of the tunnels, sex, affected side, age, Lysholm score, and Telos-SE measurement) was compared between enlarged and nonenlarged groups. Positive enlargement of the bone tunnel (>2.0 mm) was observed in 36.7% (11 of 30) on the femoral side and 33.3% (10 of 30) on the tibial side, and in 6 knees of both sides. Half of patients (15 of 30) had an enlarged tunnel on the femoral or the tibial side until 1 year postoperatively. In most cases, enlargement reached maximum at 6 months postoperatively. Female patients tended to have an enlarged tunnel, especially on the femoral side (P < .05). Tunnel enlargement was not correlated with location and angle of the tunnels. Moreover, no difference was found in Lysholm score and Telos-SE measurement between enlarged and nonenlarged groups, although the nonenlarged group tended to exhibit higher Lysholm score and lesser instability. Bone tunnel enlargement of the femoral or tibial side was observed in half of patients (6 in both sides, 5 only in the femur, and 4 only in the tibia) after ACL reconstruction was performed with a hamstring tendon fixed with an RCI screw. Female patients had a greater chance for enlargement of the femoral tunnel

  19. PIXE and cSAXS studies at the bone-cartilage interface

    International Nuclear Information System (INIS)

    Kaabar, W.; Gundogdu, O.; Bradley, D.A.; Bunk, O.; Pfeiffer, F.; Farquharson, M.J.; Webb, M.; Jeynes, C.

    2008-01-01

    Full text: Divalent cations such as Zn and Ca play a central role both in the normal processes of growth and remodelling as well as in the degenerative and inflammatory processes of articular cartilage during arthritis. These cations act as co-factors of a class of enzymes known as metalloproteinases, believed to be active during the initiation, progress and remodelling processes associated with osteoarthritis. Other important enzymes such as alkaline phosphatase, involved in cartilage mineralization, are also associated with the presence of these metallic co-factors. A number of authors have used X-ray fluorescence, employing synchrotron radiation sources to map metal ion distributions in bone and cartilage. In the present work, investigations were carried out on the distribution of metallic ions (Zn, Ca, P and S) in articular cartilage samples at the University of Surrey hosted EPSRC national ion beam facility based on a 2 MV Tandetron accelerator. An in-air beam line was used, with proton energy of 2.5 MeV. Micro Proton-Induced X-ray Emission (μ-PIXE) analysis has been made of the bone-cartilage interface for samples taken from the human femoral head. The bone-cartilage interface region between uncalcified and mineralized cartilage regions has attracted particular interest, being identified to be an active site of remodelling. Here coherent small angle X-ray scattering (cSAXS) has also been employed to investigate the structure and organization of the collagen network in decalcified diseased human femoral heads and the equine metacarpus joint, study being carried out at the Paul Scherrer Institute (PSI) synchrotron beamline cSAXS. (Fig. 1: cSAXS over a 1 mm x 1.5 mm area of a cartilage/bone sample; the left- and right hand panels corresponds to the length scales 658-568 A and 962-833 A respectively. The bar scale indicates relative orientation, from 0 deg (blue) to 90 deg (red)). The results of Fig. 1 are plotted in terms of orientation of cartilage and bone

  20. Stretching Your Energetic Budget: How Tendon Compliance Affects the Metabolic Cost of Running.

    Directory of Open Access Journals (Sweden)

    Thomas K Uchida

    Full Text Available Muscles attach to bones via tendons that stretch and recoil, affecting muscle force generation and metabolic energy consumption. In this study, we investigated the effect of tendon compliance on the metabolic cost of running using a full-body musculoskeletal model with a detailed model of muscle energetics. We performed muscle-driven simulations of running at 2-5 m/s with tendon force-strain curves that produced between 1 and 10% strain when the muscles were developing maximum isometric force. We computed the average metabolic power consumed by each muscle when running at each speed and with each tendon compliance. Average whole-body metabolic power consumption increased as running speed increased, regardless of tendon compliance, and was lowest at each speed when tendon strain reached 2-3% as muscles were developing maximum isometric force. When running at 2 m/s, the soleus muscle consumed less metabolic power at high tendon compliance because the strain of the tendon allowed the muscle fibers to operate nearly isometrically during stance. In contrast, the medial and lateral gastrocnemii consumed less metabolic power at low tendon compliance because less compliant tendons allowed the muscle fibers to operate closer to their optimal lengths during stance. The software and simulations used in this study are freely available at simtk.org and enable examination of muscle energetics with unprecedented detail.

  1. Anatomic relationship of the proximal nail matrix to the extensor hallucis longus tendon insertion.

    Science.gov (United States)

    Palomo López, P; Becerro de Bengoa Vallejo, R; López López, D; Prados Frutos, J C; Alfonso Murillo González, J; Losa Iglesias, M E

    2015-10-01

    The purpose of this study was to delineate the relationship of the terminal extensor hallucis longus tendon insertion to the proximal limit of the nail matrix of the great toe. Fifty fresh-frozen human cadaver great toes with no evidence of trauma (average age, 62.5 years; 29 males and 21 females) were used for this study. Under 25X magnification, the proximal limit of the nail matrix and the terminal bony insertion of the extensor hallucis longus tendons were identified. The distance from the terminal tendon insertion to the nail matrix was ascertained using precision calipers, an optical microscope, and autocad(®) software for windows. Twenty-five great toes were placed in a neutral formalin solution and further analysed by histological longitudinal-sections. The specimens were stained with haematoxylin and eosin and examined microscopically to determine the presence of the extensor hallucis longus tendon along the dorsal aspect of the distal phalanx of each great toe. The main result we found in great toes was that the extensor tendon is between the matrix and the phalanx and extends dorsally to the distal aspect of the distal phalanx in all, 100%, specimens. The nail matrix of the great toe is not attached to the periosteum of the dorsal aspect of the base of the distal phalanx as is the case for fingers, because the extensor hallucis tendon is plantar or directly underneath the nail matrix and the tendon is dorsal to the bone. We have found that the extensor tendon is between the matrix and the phalanx and extends dorsally to the distal aspect of the distal phalanx. The nail matrix of the great toe is not attached to the periosteum of the dorsal aspect of the base of distal phalanx as is the case in fingers, because the extensor hallucis tendon is plantar or directly underneath the nail matrix and the tendon is dorsal to the bone. Our anatomic study demonstrates that the proximal limit of the matrix and nail bed of the human great toe are dorsal and

  2. Enhancement of Tendon–Bone Healing for Anterior Cruciate Ligament (ACL Reconstruction Using Bone Marrow-Derived Mesenchymal Stem Cells Infected with BMP-2

    Directory of Open Access Journals (Sweden)

    Shiyi Chen

    2012-10-01

    Full Text Available At present, due to the growing attention focused on the issue of tendon–bone healing, we carried out an animal study of the use of genetic intervention combined with cell transplantation for the promotion of this process. Here, the efficacy of bone marrow stromal cells infected with bone morphogenetic protein-2 (BMP-2 on tendon–bone healing was determined. A eukaryotic expression vector containing the BMP-2 gene was constructed and bone marrow-derived mesenchymal stem cells (bMSCs were infected with a lentivirus. Next, we examined the viability of the infected cells and the mRNA and protein levels of BMP-2-infected bMSCs. Gastrocnemius tendons, gastrocnemius tendons wrapped by bMSCs infected with the control virus (bMSCs+Lv-Control, and gastrocnemius tendons wrapped by bMSCs infected with the recombinant BMP-2 virus (bMSCs+Lv-BMP-2 were used to reconstruct the anterior cruciate ligament (ACL in New Zealand white rabbits. Specimens from each group were harvested four and eight weeks postoperatively and evaluated using biomechanical and histological methods. The bMSCs were infected with the lentivirus at an efficiency close to 100%. The BMP-2 mRNA and protein levels in bMSCs were significantly increased after lentiviral infection. The bMSCs and BMP-2-infected bMSCs on the gastrocnemius tendon improved the biomechanical properties of the graft in the bone tunnel; specifically, bMSCs infected with BMP-2 had a positive effect on tendon–bone healing. In the four-week and eight-week groups, bMSCs+Lv-BMP-2 group exhibited significantly higher maximum loads of 29.3 ± 7.4 N and 45.5 ± 11.9 N, respectively, compared with the control group (19.9 ± 6.4 N and 21.9 ± 4.9 N (P = 0.041 and P = 0.001, respectively. In the eight-week groups, the stiffness of the bMSCs+Lv-BMP-2 group (32.5 ± 7.3 was significantly higher than that of the bMSCs+Lv-Control group (22.8 ± 7.4 or control groups (12.4 ± 6.0 (p = 0.036 and 0.001, respectively. Based on the

  3. Response of bone marrow stromal cells to graded co-electrospun scaffolds and its implications for engineering the ligament-bone interface.

    Science.gov (United States)

    Samavedi, Satyavrata; Guelcher, Scott A; Goldstein, Aaron S; Whittington, Abby R

    2012-11-01

    Biomaterial scaffolds with gradients in architecture, mechanical and chemical properties have the potential to improve the osseointegration of ligament grafts by recapitulating phenotypic gradients that exist at the natural ligament-bone (L-B) interface. Towards the larger goal of regenerating the L-B interface, this in vitro study was performed to investigate the potential of two scaffolds with mineral gradients in promoting a spatial gradient of osteoblastic differentiation. Specifically, the first graded scaffold was fabricated by co-electrospinning two polymer solutions (one doped with nano-hydroxyapatite particles) from offset spinnerets, while the second was created by immersing the first scaffold in a 5 × simulated body fluid. Rat bone marrow stromal cells, cultured in the presence of osteogenic supplements, were found to be metabolically active on all regions of both scaffolds after 1 and 7 days of culture. Gene expression of bone morphogenic protein-2 and osteopontin was elevated on mineral-containing regions as compared to regions without mineral, while the expression of alkaline phosphatase mRNA revealed the opposite trend. Finally, the presence of osteopontin and bone sialoprotein confirmed osteoblastic phenotypic maturation by day 28. This study indicates that co-electrospun scaffolds with gradients in mineral content can guide the formation of phenotypic gradients and may thus promote the regeneration of the L-B interface. Copyright © 2012 Elsevier Ltd. All rights reserved.

  4. Improvement and evaluation of thermal, electrical, sealing and mechanical contacts, and their interface materials

    Science.gov (United States)

    Luo, Xiangcheng

    Material contacts, including thermal, electrical, seating (fluid sealing and electromagnetic sealing) and mechanical (pressure) contacts, together with their interface materials, were, evaluated, and in some cases, improved beyond the state of the art. The evaluation involved the use of thermal, electrical and mechanical methods. For thermal contacts, this work evaluated and improved the heat transfer efficiency between two contacting components by developing various thermal interface pastes. Sodium silicate based thermal pastes (with boron nitride particles as the thermally conductive filler) as well as polyethylene glycol (PEG) based thermal pastes were developed and evaluated. The optimum volume fractions of BN in sodium silicate based pastes and PEG based pastes were 16% and 18% respectively. The contribution of Li+ ions to the thermal contact conductance in the PEG-based paste was confirmed. For electrical contacts, the relationship between the mechanical reliability and electrical reliability of solder/copper and silver-epoxy/copper joints was addressed. Mechanical pull-out testing was conducted on solder/copper and silver-epoxy/copper joints, while the contact electrical resistivity was measured. Cleansing of the copper surface was more effective for the reliability of silver-epoxy/copper joint than that of solder/copper joint. For sealing contacts, this work evaluated flexible graphite as an electromagnetic shielding gasket material. Flexible graphite was found to be at least comparable to conductive filled silicone (the state of the art) in terms of the shielding effectiveness. The conformability of flexible graphite with its mating metal surface under repeated compression was characterized by monitoring the contact electrical resistance, as the conformability is important to both electromagnetic scaling and fluid waling using flexible graphite. For mechanical contacts, this work focused on the correlation of the interface structure (such as elastic

  5. Autologous implant of bone marrow mononuclear stem-cells as treatment for equine bicipital tendonitis: case report Implante autólogo de células mononucleares de médula ósea como tratamiento de tendinitis bicipital equina: reporte de caso clínico

    OpenAIRE

    BC Menarim; GA Fortini; PS Álvarez; J Gómez; CD Jarrín; A Ramírez; JS Galecio

    2012-01-01

    Bicipital bursitis in the horse, the inflammation of the bicipital tendon and its surrounding bursa, has been reported to represent a low percentage of lameness cause. However, it is the main cause of lameness associated to the shoulder region and it has been under diagnosed. Due to high recurrence in different types of tendon injuries, treatments aiming to re-establish tendon functionality have been a focus of research. The aim of this study is to report the implant of a bone marrow mononucl...

  6. Behavior of bone cells in contact with magnesium implant material.

    Science.gov (United States)

    Burmester, Anna; Willumeit-Römer, Regine; Feyerabend, Frank

    2017-01-01

    Magnesium-based implants exhibit several advantages, such as biodegradability and possible osteoinductive properties. Whether the degradation may induce cell type-specific changes in metabolism still remains unclear. To examine the osteoinductivity mechanisms, the reaction of bone-derived cells (MG63, U2OS, SaoS2, and primary human osteoblasts (OB)) to magnesium (Mg) was determined. Mg-based extracts were used to mimic more realistic Mg degradation conditions. Moreover, the influence of cells having direct contact with the degrading Mg metal was investigated. In exposure to extracts and in direct contact, the cells decreased pH and osmolality due to metabolic activity. Proliferating cells showed no significant reaction to extracts, whereas differentiating cells were negatively influenced. In contrast to extract exposure, where cell size increased, in direct contact to magnesium, cell size was stable or even decreased. The amount of focal adhesions decreased over time on all materials. Genes involved in bone formation were significantly upregulated, especially for primary human osteoblasts. Some osteoinductive indicators were observed for OB: (i) an increased cell count after extract addition indicated a higher proliferation potential; (ii) increased cell sizes after extract supplementation in combination with augmented adhesion behavior of these cells suggest an early switch to differentiation; and (iii) bone-inducing gene expression patterns were determined for all analyzed conditions. The results from the cell lines were inhomogeneous and showed no specific stimulus of Mg. The comparison of the different cell types showed that primary cells of the investigated tissue should be used as an in vitro model if Mg is analyzed. © 2015 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 165-179, 2017. © 2015 Wiley Periodicals, Inc.

  7. Stress examination of flexor tendon pulley rupture in the crimp grip position: a 1.5-Tesla MRI cadaver study

    Energy Technology Data Exchange (ETDEWEB)

    Bayer, Thomas; Janka, Rolf [University of Erlangen-Nuremberg, Department of Radiology, Erlangen (Germany); Fries, Simon [Cantonal Hospital Lucerne, Orthopaedic Department, Wolhusen (Switzerland); Schweizer, Andreas [University of Zurich, Department of Orthopaedics, Balgrist, Zurich (Switzerland); Schoeffl, Isabelle [Klinikum Bamberg, Department of Pediatrics, Bamberg (Germany); Bongartz, Georg [University Basel, Department of Radiology, Basel (Switzerland)

    2015-01-15

    The objectives of this study were the evaluation of flexor tendon pulley rupture of the fingers in the crimp grip position using magnetic resonance imaging (MRI) and the comparison of the results with MRI in the neutral position in a cadaver study. MRI in the crimp grip position and in the neutral position was performed in 21 cadaver fingers with artificially created flexor tendon pulley tears (combined pulley rupture, n = 14; single pulley rupture, n = 7). Measurement of the distance between the tendon and bone was performed. Images were evaluated by two readers, first independently and in cases of discrepancy in consensus. Sensitivity and specificity for detecting combined pulley ruptures were calculated. Tendon bone distances were significantly higher in the crimp grip position than in the neutral position. Sensitivity and specificity for detecting combined pulley rupture were 92.86 % and 100 % respectively in the crimp grip position and 78.57 % and 85.71 % respectively in the neutral position. Kappa values for interobserver reliability were 0.87 in the crimp grip position and 0.59 in the neutral position. MRI examination in the crimp grip position results in higher tendon bone distances by subjecting the pulleys to a higher strain, which facilitates image evaluation with higher interobserver reliability, higher sensitivity, and higher specificity for combined pulley rupture compared with examination in the neutral position. (orig.)

  8. Automatic segmentation of the bone and extraction of the bone-cartilage interface from magnetic resonance images of the knee

    International Nuclear Information System (INIS)

    Fripp, Jurgen; Crozier, Stuart; Warfield, Simon K; Ourselin, Sebastien

    2007-01-01

    The accurate segmentation of the articular cartilages from magnetic resonance (MR) images of the knee is important for clinical studies and drug trials into conditions like osteoarthritis. Currently, segmentations are obtained using time-consuming manual or semi-automatic algorithms which have high inter- and intra-observer variabilities. This paper presents an important step towards obtaining automatic and accurate segmentations of the cartilages, namely an approach to automatically segment the bones and extract the bone-cartilage interfaces (BCI) in the knee. The segmentation is performed using three-dimensional active shape models, which are initialized using an affine registration to an atlas. The BCI are then extracted using image information and prior knowledge about the likelihood of each point belonging to the interface. The accuracy and robustness of the approach was experimentally validated using an MR database of fat suppressed spoiled gradient recall images. The (femur, tibia, patella) bone segmentation had a median Dice similarity coefficient of (0.96, 0.96, 0.89) and an average point-to-surface error of 0.16 mm on the BCI. The extracted BCI had a median surface overlap of 0.94 with the real interface, demonstrating its usefulness for subsequent cartilage segmentation or quantitative analysis

  9. Automatic segmentation of the bone and extraction of the bone-cartilage interface from magnetic resonance images of the knee

    Energy Technology Data Exchange (ETDEWEB)

    Fripp, Jurgen [BioMedIA Lab, Autonomous Systems Laboratory, CSIRO ICT Centre, Level 20, 300 Adelaide street, Brisbane, QLD 4001 (Australia); Crozier, Stuart [School of Information Technology and Electrical Engineering, University of Queensland, St Lucia, QLD 4072 (Australia); Warfield, Simon K [Computational Radiology Laboratory, Harvard Medical School, Children' s Hospital Boston, 300 Longwood Avenue, Boston, MA 02115 (United States); Ourselin, Sebastien [BioMedIA Lab, Autonomous Systems Laboratory, CSIRO ICT Centre, Level 20, 300 Adelaide street, Brisbane, QLD 4001 (Australia)

    2007-03-21

    The accurate segmentation of the articular cartilages from magnetic resonance (MR) images of the knee is important for clinical studies and drug trials into conditions like osteoarthritis. Currently, segmentations are obtained using time-consuming manual or semi-automatic algorithms which have high inter- and intra-observer variabilities. This paper presents an important step towards obtaining automatic and accurate segmentations of the cartilages, namely an approach to automatically segment the bones and extract the bone-cartilage interfaces (BCI) in the knee. The segmentation is performed using three-dimensional active shape models, which are initialized using an affine registration to an atlas. The BCI are then extracted using image information and prior knowledge about the likelihood of each point belonging to the interface. The accuracy and robustness of the approach was experimentally validated using an MR database of fat suppressed spoiled gradient recall images. The (femur, tibia, patella) bone segmentation had a median Dice similarity coefficient of (0.96, 0.96, 0.89) and an average point-to-surface error of 0.16 mm on the BCI. The extracted BCI had a median surface overlap of 0.94 with the real interface, demonstrating its usefulness for subsequent cartilage segmentation or quantitative analysis.

  10. Energy deposition at the bone-tissue interface from nuclear fragments produced by high-energy nucleons

    Science.gov (United States)

    Cucinotta, Francis A.; Hajnal, Ferenc; Wilson, John W.

    1990-01-01

    The transport of nuclear fragmentation recoils produced by high-energy nucleons in the region of the bone-tissue interface is considered. Results for the different flux and absorbed dose for recoils produced by 1 GeV protons are presented in a bidirectional transport model. The energy deposition in marrow cavities is seen to be enhanced by recoils produced in bone. Approximate analytic formulae for absorbed dose near the interface region are also presented for a simplified range-energy model.

  11. Multilayer scaffolds in orthopaedic tissue engineering.

    Science.gov (United States)

    Atesok, Kivanc; Doral, M Nedim; Karlsson, Jon; Egol, Kenneth A; Jazrawi, Laith M; Coelho, Paulo G; Martinez, Amaury; Matsumoto, Tomoyuki; Owens, Brett D; Ochi, Mitsuo; Hurwitz, Shepard R; Atala, Anthony; Fu, Freddie H; Lu, Helen H; Rodeo, Scott A

    2016-07-01

    The purpose of this study was to summarize the recent developments in the field of tissue engineering as they relate to multilayer scaffold designs in musculoskeletal regeneration. Clinical and basic research studies that highlight the current knowledge and potential future applications of the multilayer scaffolds in orthopaedic tissue engineering were evaluated and the best evidence collected. Studies were divided into three main categories based on tissue types and interfaces for which multilayer scaffolds were used to regenerate: bone, osteochondral junction and tendon-to-bone interfaces. In vitro and in vivo studies indicate that the use of stratified scaffolds composed of multiple layers with distinct compositions for regeneration of distinct tissue types within the same scaffold and anatomic location is feasible. This emerging tissue engineering approach has potential applications in regeneration of bone defects, osteochondral lesions and tendon-to-bone interfaces with successful basic research findings that encourage clinical applications. Present data supporting the advantages of the use of multilayer scaffolds as an emerging strategy in musculoskeletal tissue engineering are promising, however, still limited. Positive impacts of the use of next generation scaffolds in orthopaedic tissue engineering can be expected in terms of decreasing the invasiveness of current grafting techniques used for reconstruction of bone and osteochondral defects, and tendon-to-bone interfaces in near future.

  12. Non-Amontons-Coulomb local friction law of randomly rough contact interfaces with rubber

    OpenAIRE

    Nguyen, D. T.; Wandersman, E.; Prevost, A.; Chenadec, Y. Le; Fretigny, C.; Chateauminois, A.

    2017-01-01

    We report on measurements of the local friction law at a multi-contact interface formed between a smooth rubber and statistically rough glass lenses, under steady state friction. Using contact imaging, surface displacements are measured, and inverted to extract both distributions of frictional shear stress and contact pressure with a spatial resolution of about 10~$\\mu$m. For a glass surface whose topography is self-affine with a Gaussian height asperity distribution, the local frictional she...

  13. Triceps brachii tendon: anatomic-MR imaging study in cadavers with histologic correlation

    International Nuclear Information System (INIS)

    Belentani, Clarissa; Pastore, Daniel; Wangwinyuvirat, Mani; Dirim, Berna; Trudell, Debra J.; Resnick, Donald; Haghighi, Parviz

    2009-01-01

    The purpose of this cadaveric study was to describe the normal MR anatomy of the triceps brachii tendon (TBT) insertion, to correlate the findings with those seen in anatomic sections and histopathologic analysis, and to review triceps tendon injuries. Twelve cadaveric elbows were used according to institution guidelines. T1-weighted spin-echo MR images were acquired in three planes. Findings on MR imaging were correlated with those derived from anatomic and histologic study. On MR images, the TBT had a bipartite appearance as it inserted on olecranon in all specimens. The insertion of the medial head was deeper than that of the long and lateral heads and was mainly muscular at its insertion, with a small amount of the tendon blending with the muscle distally, necessitating histologic analysis to determine if there was tendon blending with the muscle at the site of insertion and if the medial head inserted together with the common tendon or as a single unit. At histopathologic analysis, the three heads of the triceps tendon had a common insertion on the olecranon. The bipartite aspect of the tendon that was identified in the MR images was not seen by histologic study, indicating that there was a union of the medial and common tendons just before they inserted into bone. TBT has a bipartite appearance on MR images and inserts on olecranon as a single unit. (orig.)

  14. Triceps brachii tendon: anatomic-MR imaging study in cadavers with histologic correlation

    Energy Technology Data Exchange (ETDEWEB)

    Belentani, Clarissa [University of California, Department of Radiology, San Diego, CA (United States); Pastore, Daniel; Wangwinyuvirat, Mani; Dirim, Berna; Trudell, Debra J.; Resnick, Donald [University of California, Department of Radiology, San Diego, CA (United States); University of California, VA Medical Center, San Diego, CA (United States); Haghighi, Parviz [University of California, VA Medical Center, San Diego, CA (United States); University of California, Department of Histology, San Diego (United States)

    2009-02-15

    The purpose of this cadaveric study was to describe the normal MR anatomy of the triceps brachii tendon (TBT) insertion, to correlate the findings with those seen in anatomic sections and histopathologic analysis, and to review triceps tendon injuries. Twelve cadaveric elbows were used according to institution guidelines. T1-weighted spin-echo MR images were acquired in three planes. Findings on MR imaging were correlated with those derived from anatomic and histologic study. On MR images, the TBT had a bipartite appearance as it inserted on olecranon in all specimens. The insertion of the medial head was deeper than that of the long and lateral heads and was mainly muscular at its insertion, with a small amount of the tendon blending with the muscle distally, necessitating histologic analysis to determine if there was tendon blending with the muscle at the site of insertion and if the medial head inserted together with the common tendon or as a single unit. At histopathologic analysis, the three heads of the triceps tendon had a common insertion on the olecranon. The bipartite aspect of the tendon that was identified in the MR images was not seen by histologic study, indicating that there was a union of the medial and common tendons just before they inserted into bone. TBT has a bipartite appearance on MR images and inserts on olecranon as a single unit. (orig.)

  15. The normal tendon sheath of the second to fifth fingers as seen on oblique views

    International Nuclear Information System (INIS)

    Fischer, E.

    1984-01-01

    Oblique views of the fingers, using a low kilovolt technique, show a portion of the tendon sheaths which can be regarded as representative of the entire sheath. Because of the varying obliquity of each finger, this proportion differs in the fingers. With increasing age the projected portion of the sheath becomes smaller because it is covered by increasing bone formation in the insertion of the tendon sheat. Normal values have been obtained for adults according to their decades; from these, quite minor degrees of tendon sheat thickening can be determined. In camptodactyly of the fifth finger, which is not uncommon, the tendon sheat may be widened in the absence of a tenosynovitis. (orig.) [de

  16. Texture analyses of Sauropod dinosaur bones from Tendaguru

    Energy Technology Data Exchange (ETDEWEB)

    Pyzalla, A.R. [TU Wien, Institute of Material Science and Technology, Karlsplatz 13-308, A-1040 Vienna (Austria) and MPI fuer Eisenforschung GmbH, Max-Planck-Str. 1, D-40237 Duesseldorf (Germany)]. E-mail: pyzalla@mpie.de; Sander, P.M. [University of Bonn, Institute of Palaeontology, Nusseallee, D-53115 Bonn (Germany); Hansen, A. [TU Clausthal, Institute of Materials Science and Engineering. A, Structural Materials: Properties, Microstructure and Processingnd GKSS Research Centre Geesthacht GmbH, Geesthacht, Max-Planck-Str.1, D-21502 Geesthacht (Germany); Ferreyro, R. [TU Wien, Institute of Material Science and Technology, Karlsplatz 13-308, A-1040 Vienna (Austria); Yi, S.-B. [TU Clausthal, Institute of Materials Science and Engineering. A, Structural Materials: Properties, Microstructure and Processingnd GKSS Research Centre Geesthacht GmbH, Geesthacht, Max-Planck-Str.1, D-21502 Geesthacht (Germany); MPI fuer Eisenforschung GmbH, Max-Planck-Str. 1, D-40237 Duesseldorf (Germany); Stempniewicz, M. [TU Wien, Institute of Material Science and Technology, Karlsplatz 13-308, A-1040 Vienna (Austria); Brokmeier, H.-G. [TU Clausthal, Institute of Materials Science and Engineering. A, Structural Materials: Properties, Microstructure and Processingnd GKSS Research Centre Geesthacht GmbH, Geesthacht, Max-Planck-Str.1, D-21502 Geesthacht (Germany)

    2006-11-10

    The apatite texture of fossil Brachiosaurus brancai and Barosaurus africanus sauropod bones from the excavation site at Tendaguru, Tanzania, was characterized by neutron diffraction pole figures. The results obtained reveal predominantly <0 0 0 1>-fibre textures of the apatite; the fibre direction coincides with the longitudinal direction of the long bones of the skeletons. Neutron pole figures further indicate that other texture types may also be present. Texture strength is similar to dinosaur tendons and contemporary turkey tendon studied by others. Variations of texture strength across the bone wall cross-sections are not significantly large.

  17. Floating fat in the wrist joint and in the tendon sheaths

    Energy Technology Data Exchange (ETDEWEB)

    Le Corroller, Thomas; Zink, Jean-Vincent; Champsaur, Pierre [Hopital Sainte-Marguerite, Radiology Department, Marseille (France); Parratte, Sebastien; Argenson, Jean-Noel [Hopital Sainte-Marguerite, Orthopaedic Surgery Department, Marseille (France)

    2010-09-15

    A traumatic fat effusion in a tendon sheath is an unreported entity. We report on the clinical and imaging features, including radiography and computed tomography (CT), of a fat-density effusion in the wrist joint and tendon sheaths of the extensor pollicis longus, extensor carpi radialis longus, and extensor carpi radialis brevis in a 28-year-old patient after a roller-skating accident. Radiographs showed a fracture of the distal radius and a wrist joint effusion. Preoperative CT examination exhibited two distinct layers resulting in a fat-fluid level pathognomonic of lipohemarthrosis in the radiocarpal joint. In addition, a fat-density effusion was noted in the sheaths of the second and third compartment extensor tendons. The lipohemarthrosis depicted on imaging classically results from the extrusion of fat from bone marrow into the joint space after an intraarticular fracture. Similarly, a traumatic fat effusion in a tendon sheath presents characteristic imaging features that may help to diagnose a potentially overlooked fracture. (orig.)

  18. Floating fat in the wrist joint and in the tendon sheaths

    International Nuclear Information System (INIS)

    Le Corroller, Thomas; Zink, Jean-Vincent; Champsaur, Pierre; Parratte, Sebastien; Argenson, Jean-Noel

    2010-01-01

    A traumatic fat effusion in a tendon sheath is an unreported entity. We report on the clinical and imaging features, including radiography and computed tomography (CT), of a fat-density effusion in the wrist joint and tendon sheaths of the extensor pollicis longus, extensor carpi radialis longus, and extensor carpi radialis brevis in a 28-year-old patient after a roller-skating accident. Radiographs showed a fracture of the distal radius and a wrist joint effusion. Preoperative CT examination exhibited two distinct layers resulting in a fat-fluid level pathognomonic of lipohemarthrosis in the radiocarpal joint. In addition, a fat-density effusion was noted in the sheaths of the second and third compartment extensor tendons. The lipohemarthrosis depicted on imaging classically results from the extrusion of fat from bone marrow into the joint space after an intraarticular fracture. Similarly, a traumatic fat effusion in a tendon sheath presents characteristic imaging features that may help to diagnose a potentially overlooked fracture. (orig.)

  19. The anatomical footprint of the Achilles tendon: a cadaveric study.

    Science.gov (United States)

    Ballal, M S; Walker, C R; Molloy, A P

    2014-10-01

    We dissected 12 fresh-frozen leg specimens to identify the insertional footprint of each fascicle of the Achilles tendon on the calcaneum in relation to their corresponding muscles. A further ten embalmed specimens were examined to confirm an observation on the retrocalcaneal bursa. The superficial part of the insertion of the Achilles tendon is represented by fascicles from the medial head of the gastrocnemius muscle, which is inserted over the entire width of the inferior facet of the calcaneal tuberosity. In three specimens this insertion was in continuity with the plantar fascia in the form of periosteum. The deep part of the insertion of the Achilles tendon is made of fascicles from the soleus tendon, which insert on the medial aspect of the middle facet of the calcaneal tuberosity, while the fascicles of the lateral head of the gastrocnemius tendon insert on the lateral aspect of the middle facet of the calcaneal tuberosity. A bicameral retrocalcaneal bursa was present in 15 of the 22 examined specimens. This new observation and description of the insertional footprint of the Achilles tendon and the retrocalcaneal bursa may allow a better understanding of the function of each muscular part of the gastrosoleus complex. This may have clinical relevance in the treatment of Achilles tendinopathies. ©2014 The British Editorial Society of Bone & Joint Surgery.

  20. Tissue-Engineered Tendon for Enthesis Regeneration in a Rat Rotator Cuff Model

    Directory of Open Access Journals (Sweden)

    Michael J. Smietana

    2017-06-01

    Full Text Available Healing of rotator cuff (RC injuries with current suture or augmented scaffold techniques fails to regenerate the enthesis and instead forms a weaker fibrovascular scar that is prone to subsequent failure. Regeneration of the enthesis is the key to improving clinical outcomes for RC injuries. We hypothesized that the utilization of our tissue-engineered tendon to repair either an acute or a chronic full-thickness supraspinatus tear would regenerate a functional enthesis and return the biomechanics of the tendon back to that found in native tissue. Engineered tendons were fabricated from bone marrow-derived mesenchymal stem cells utilizing our well-described fabrication technology. Forty-three rats underwent unilateral detachment of the supraspinatus tendon followed by acute (immediate or chronic (4 weeks retracted repair by using either our engineered tendon or a trans-osseous suture technique. Animals were sacrificed at 8 weeks. Biomechanical and histological analyses of the regenerated enthesis and tendon were performed. Statistical analysis was performed by using a one-way analysis of variance with significance set at p < 0.05. Acute repairs using engineered tendon had improved enthesis structure and lower biomechanical failures compared with suture repairs. Chronic repairs with engineered tendon had a more native-like enthesis with increased fibrocartilage formation, reduced scar formation, and lower biomechanical failure compared with suture repair. Thus, the utilization of our tissue-engineered tendon showed improve enthesis regeneration and improved function in chronic RC repairs compared with suture repair. Clinical Significance: Our engineered tendon construct shows promise as a clinically relevant method for repair of RC injuries.

  1. Volumetric quantification of bone-implant contact using micro-computed tomography analysis based on region-based segmentation.

    Science.gov (United States)

    Kang, Sung-Won; Lee, Woo-Jin; Choi, Soon-Chul; Lee, Sam-Sun; Heo, Min-Suk; Huh, Kyung-Hoe; Kim, Tae-Il; Yi, Won-Jin

    2015-03-01

    We have developed a new method of segmenting the areas of absorbable implants and bone using region-based segmentation of micro-computed tomography (micro-CT) images, which allowed us to quantify volumetric bone-implant contact (VBIC) and volumetric absorption (VA). The simple threshold technique generally used in micro-CT analysis cannot be used to segment the areas of absorbable implants and bone. Instead, a region-based segmentation method, a region-labeling method, and subsequent morphological operations were successively applied to micro-CT images. The three-dimensional VBIC and VA of the absorbable implant were then calculated over the entire volume of the implant. Two-dimensional (2D) bone-implant contact (BIC) and bone area (BA) were also measured based on the conventional histomorphometric method. VA and VBIC increased significantly with as the healing period increased (pimplants using micro-CT analysis using a region-based segmentation method.

  2. The quantitative assessment of peri-implant bone responses using histomorphometry and micro-computed tomography.

    Science.gov (United States)

    Schouten, Corinne; Meijer, Gert J; van den Beucken, Jeroen J J P; Spauwen, Paul H M; Jansen, John A

    2009-09-01

    In the present study, the effects of implant design and surface properties on peri-implant bone response were evaluated with both conventional histomorphometry and micro-computed tomography (micro-CT), using two geometrically different dental implants (Screw type, St; Push-in, Pi) either or not surface-modified (non-coated, CaP-coated, or CaP-coated+TGF-beta1). After 12 weeks of implantation in a goat femoral condyle model, peri-implant bone response was evaluated in three different zones (inner: 0-500 microm; middle: 500-1000 microm; and outer: 1000-1500 microm) around the implant. Results indicated superiority of conventional histomorphometry over micro-CT, as the latter is hampered by deficits in the discrimination at the implant/tissue interface. Beyond this interface, both analysis techniques can be regarded as complementary. Histomorphometrical analysis showed an overall higher bone volume around St compared to Pi implants, but no effects of surface modification were observed. St implants showed lowest bone volumes in the outer zone, whereas inner zones were lowest for Pi implants. These results implicate that for Pi implants bone formation started from two different directions (contact- and distance osteogenesis). For St implants it was concluded that undersized implantation technique and loosening of bone fragments compress the zones for contact and distant osteogenesis, thereby improving bone volume at the interface significantly.

  3. The contact heat conductance at diamond-OFHC copper interface with GaIn eutectic as a heat transfer medium

    International Nuclear Information System (INIS)

    Assoufid, L.; Khounsary, A.M.

    1996-01-01

    Results of an experimental study of the contact heat conductance across a single diamond crystal interface with OFHC copper (Cu) are reported. Gallium-indium (GaIn) eutectic was used as an interstitial material. Contact conductance data are important in the design and the prediction of the performance of x-ray diamond monochromators under high-heat-load conditions. Two sets of experiments were carried out. In one, the copper surface in contact with diamond was polished and then electroless plated with 1 μm of nickel, while in the other, the copper contact surface was left as machined. Measured average interface heat conductances are 44.7 ±8 W/cm 2 -K for nonplated copper and 23.0 ±3 W/cm 2 -K for nickel-plated copper. For reference, the thermal contact conductances at a copper-copper interface (without diamond) were also measured, and the results are reported. A typical diamond monochromator, 0.2 mm thick, will absorb about 44 W under a standard undulator beam at the Advanced Photon Source. The measured conductance for nickel-plated copper suggests that the temperature drop across the interface of diamond and nickel-plated copper, with a 20 mm 2 contact area, will be about 10 degree C. Therefore temperature rises are rather modest, and the accuracy of the measured contact conductances presented here are sufficient for design purposes

  4. The “Parachute” Technique: A Simple and Effective Single-Row Procedure to Achieve an Increased Contact Area Between the Cuff-Tendon and Its Footprint

    OpenAIRE

    Natera, Luis; Consigliere, Paolo; Witney-Lagen, Caroline; Brugera, Juan; Sforza, Giuseppe; Atoun, Ehud; Levy, Ofer

    2017-01-01

    Many techniques of arthroscopic rotator cuff repair have been described. No significant differences in clinical outcomes or rerupture rates have been observed when comparing single-row with double-row methods. Not all single- and double-row repairs are the same. The details of the technique used are crucial. It has been shown that the suture-tendon interface is the weakest point of the reconstruction. Therefore, the biomechanical properties of rotator cuff repairs might be influenced more by ...

  5. Bone-Implant Contact around Crestal and Subcrestal Dental Implants Submitted to Immediate and Conventional Loading

    Directory of Open Access Journals (Sweden)

    Ana Emília Farias Pontes

    2014-01-01

    Full Text Available The present study aims to evaluate the influence of apicocoronal position and immediate and conventional loading in the percentage of bone-implant contact (BIC. Thus, 36 implants were inserted in the edentulous mandible from six dogs. Three implants were installed in each hemimandible, in different positions in relation to the ridge: Bone Level (at crestal bone level, Minus 1 (one millimeter apical to crestal bone, and Minus 2 (two millimeters apical to crestal bone. In addition, each hemimandible was submitted to a loading protocol: immediate (prosthesis installed 24 hours after implantation or conventional (prosthesis installed 120 days after implantation. Ninety days after, animals were killed, and implant and adjacent tissues were prepared for histometric analysis. BIC values from immediate loaded implants were 58.7%, 57.7%, and 51.1%, respectively, while conventional loaded implants were 61.8%, 53.8%, and 68.4%. Differences statistically significant were not observed among groups (P=0.10, ANOVA test. These findings suggest that different apicocoronal positioning and loading protocols evaluated did not interfere in the percentage of bone-implant contact, suggesting that these procedures did not jeopardize osseointegration.

  6. Improved healing of transected rabbit Achilles tendon after a single injection of cartilage-derived morphogenetic protein-2.

    Science.gov (United States)

    Forslund, Carina; Aspenberg, Per

    2003-01-01

    Achilles tendon ruptures in humans might be treated more efficiently with the help of a growth factor. Cartilage-derived morphogenetic protein-2 has been shown to induce formation of tendon-like tissue. Cartilage-derived morphogenetic protein-2 has a positive effect on mechanical parameters for tendon healing in a rabbit model with Achilles tendon transection. Controlled laboratory study. The right Achilles tendon of 40 rabbits was transected without tendon suture. Cartilage-derived morphogenetic protein-2 (10 micro g) or vehicle control (acetate buffer) was injected locally 2 hours postoperatively. All tendons were tested biomechanically at 8 and 14 days, and treated tendons were histologically and radiographically evaluated at 56 days. At 14 days, both failure load and stiffness of treated tendons were increased by 35%. The treated tendons had significantly larger callus size at 8 and 14 days. Histologic and radiographic examination showed no signs of ossification in the treated tendons after 56 days. A single injection of cartilage-derived morphogenetic protein-2 led to a stronger and stiffer tendon callus than that in the controls without inducing bone formation. Similar results from a larger animal model would suggest a possible future use of cartilage-derived morphogenetic protein-2 in the treatment of human Achilles tendon ruptures.

  7. Influence of controlled immediate loading and implant design on peri-implant bone formation.

    Science.gov (United States)

    Vandamme, Katleen; Naert, Ignace; Geris, Liesbet; Vander Sloten, Jozef; Puers, Robert; Duyck, Joke

    2007-02-01

    Tissue formation at the implant interface is known to be sensitive to mechanical stimuli. The aim of the study was to compare the bone formation around immediately loaded versus unloaded implants in two different implant macro-designs. A repeated sampling bone chamber with a central implant was installed in the tibia of 10 rabbits. Highly controlled loading experiments were designed for a cylindrical (CL) and screw-shaped (SL) implant, while the unloaded screw-shaped (SU) implant served as a control. An F-statistic model with alpha=5% determined statistical significance. A significantly higher bone area fraction was observed for SL compared with SU (pimplant contact occurred was the highest for SL and significantly different from SU (pimplant contact was observed, a loading (SL versus SU: p=0.0049) as well as an implant geometry effect (SL versus CL: p=0.01) was found, in favour of the SL condition. Well-controlled immediate implant loading accelerates tissue mineralization at the interface. Adequate bone stimulation via mechanical coupling may account for the larger bone response around the screw-type implant compared with the cylindrical implant.

  8. Characterization of differential properties of rabbit tendon stem cells and tenocytes

    Directory of Open Access Journals (Sweden)

    Wang James

    2010-01-01

    Full Text Available Abstract Background Tendons are traditionally thought to consist of tenocytes only, the resident cells of tendons; however, a recent study has demonstrated that human and mouse tendons also contain stem cells, referred to as tendon stem/progenitor cells (TSCs. However, the differential properties of TSCs and tenocytes remain largely undefined. This study aims to characterize the properties of these tendon cells derived from rabbits. Methods TSCs and tenocytes were isolated from patellar and Achilles tendons of rabbits. The differentiation potential and cell marker expression of the two types of cells were examined using histochemical, immunohistochemical, and qRT-PCR analysis as well as in vivo implantation. In addition, morphology, colony formation, and proliferation of TSCs and tenocytes were also compared. Results It was found that TSCs were able to differentiate into adipocytes, chondrocytes, and osteocytes in vitro, and form tendon-like, cartilage-like, and bone-like tissues in vivo. In contrast, tenocytes had little such differentiation potential. Moreover, TSCs expressed the stem cell markers Oct-4, SSEA-4, and nucleostemin, whereas tenocytes expressed none of these markers. Morphologically, TSCs possessed smaller cell bodies and larger nuclei than ordinary tenocytes and had cobblestone-like morphology in confluent culture whereas tenocytes were highly elongated. TSCs also proliferated more quickly than tenocytes in culture. Additionally, TSCs from patellar tendons formed more numerous and larger colonies and proliferated more rapidly than TSCs from Achilles tendons. Conclusions TSCs exhibit distinct properties compared to tenocytes, including differences in cell marker expression, proliferative and differentiation potential, and cell morphology in culture. Future research should investigate the mechanobiology of TSCs and explore the possibility of using TSCs to more effectively repair or regenerate injured tendons.

  9. Anatomic single-bundle anterior cruciate ligament reconstruction improves walking economy: hamstrings tendon versus patellar tendon grafts.

    Science.gov (United States)

    Iliopoulos, Efthymios; Galanis, Nikiforos; Zafeiridis, Andreas; Iosifidis, Michael; Papadopoulos, Pericles; Potoupnis, Michael; Geladas, Nikolaos; Vrabas, Ioannis S; Kirkos, John

    2017-10-01

    Anterior cruciate ligament (ACL) injury is associated with a pathologic gait pattern and increased energy cost during locomotion. ACL reconstruction could improve the gait pattern. Hamstrings tendon (HAM) and bone-patellar tendon-bone (BPTB) grafts are usually used for reconstruction. The aim of this study was to compare the efficacy of anatomic ACL reconstruction with HAM and BPTB grafts on improving and normalizing the energy cost and physiologic reserves during flat, uphill, and downhill walking. Twenty male subjects with unilateral ACL injuries were randomly assigned to ACL reconstruction with a HAM (n = 10) or BPTB (n = 10) graft. Ten matched controls were also enrolled. All participants performed three 8-min walking tasks at 0, +10, and -10 % gradients before and 9 months after surgery. Energy cost (oxygen consumption, VO 2 ), heart rate (HR), and ventilation (VE) were measured. Lysholm/IKDC scores were recorded. Pre-operatively, VO 2 , HR, and VE were higher in the HAM and BPTB groups than in controls during walking at 0, +10, and -10 % gradients (p energy cost and nearly normalized locomotion economy and cardiorespiratory reserves during flat, uphill, and downhill walking. The improved locomotion economy is an additional benefit of anatomic ACL reconstruction, irrespective of the type of graft used, that the orthopaedic surgeons should consider. II.

  10. Ultrasound Characteristics of the Achilles Tendon in Tophaceous Gout: A Comparison with Age- and Sex-matched Controls.

    Science.gov (United States)

    Carroll, Matthew; Dalbeth, Nicola; Allen, Bruce; Stewart, Sarah; House, Tony; Boocock, Mark; Frampton, Christopher; Rome, Keith

    2017-10-01

    To investigate the frequency and distribution of characteristics of the Achilles tendon (AT) in people with tophaceous gout using musculoskeletal ultrasound (US). Twenty-four participants with tophaceous gout and 24 age- and sex-matched controls without gout or other arthritis were recruited. All participants underwent a greyscale and power Doppler US examination. The AT was divided into 3 anatomical zones (insertion, pre-insertional, and proximal to the mid-section). The following US characteristics were assessed: tophus, tendon echogenicity, tendon vascularity, tendon morphology, entheseal characteristics, bursal morphology, and calcaneal bone profile. The majority of the participants with tophaceous gout were middle-aged men (n = 22, 92%) predominately of European ethnicity (n = 14, 58%). Tophus deposition was observed in 73% (n = 35) of tendons in those with gout and in none of the controls (p gout compared to controls. High prevalence of entheseal calcifications, calcaneal bone cortex irregularities, and calcaneal enthesophytes were observed in both gout participants and controls, without differences between groups. Intratendinous structural damage was rare. Hyperechoic spots were significantly more common at the insertion compared to the zone proximal to the mid-section (p gout. Despite crystal deposition, intratendinous structural changes are infrequent. Many characteristics observed in the AT in people with tophaceous gout, particularly at the calcaneal enthesis, are not disease-specific.

  11. Novel hybrid drilling protocol: evaluation for the implant healing--thermal changes, crestal bone loss, and bone-to-implant contact.

    Science.gov (United States)

    Calvo-Guirado, José Luis; Delgado-Peña, Jorge; Maté-Sánchez, Jose E; Mareque Bueno, Javier; Delgado-Ruiz, Rafael Arcesio; Romanos, Georgios E

    2015-07-01

    To evaluate a new hybrid drilling protocol, by the analysis of thermal changes in vitro, and their effects in the crestal bone loss and bone-to-implant contact in vivo. Temperature changes during simulated osteotomies with a hybrid drilling technique (biologic plus simplified) (test) versus an incremental drilling technique (control) were investigated. One hundred and twenty random osteotomies were performed (60 by group) in pig ribs up to 3.75-mm-diameter drill to a depth of 10 mm. Thermal changes and time were recorded by paired thermocouples. In a parallel experiment, bilateral mandibular premolars P2, P3, P4, and first molar M1 were extracted from six dogs. After 2-month healing, implant sites were randomly prepared using either of the drilling techniques. Forty eight implants of 3.75 mm diameter and 10 mm length were inserted. The dogs were euthanized at 30 and 90 days, and crestal bone loss (CBL) and bone-to-implant contact (BIC) were evaluated. The control group showed maximum temperatures of 35.3 °C ± 1.8 °C, ΔT of 10.4 °C, and a mean time of 100 s/procedure; meanwhile, the test group showed maximum temperatures of 36.7 °C ± 1.2 °C, ΔT of 8.1 °C, and a mean time of 240 s/procedure. After 30 days, CBL values for both groups (test: 1.168 ± 0.194 mm; control: 1.181 ± 0.113 mm) and BIC values (test: 43 ± 2.8%; control: 45 ± 1.3%) were similar, without significant differences (P > 0.05). After 90 days, CBL (test: 1.173 ± 0.187 mm; control: 1.205 ± 0.122 mm) and BIC (test: 64 ± 3.3%; control: 64 ± 2.4%) values were similar, without significant differences (P > 0.05). The BIC values were increased at 90 days in both groups compared with the 30-day period (P drilling procedure in vitro. Crestal bone loss and bone-to-implant contact in the hybrid drilling protocol are comparable with the conventional drilling protocol and do not affect the osseointegration process in vivo. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  12. Quantification of the Contact Area at the Head-Stem Taper Interface of Modular Hip Prostheses.

    Science.gov (United States)

    Witt, Florian; Gührs, Julian; Morlock, Michael M; Bishop, Nicholas E

    2015-01-01

    Corrosion of modular taper junctions of hip implants may be associated with clinical failure. Taper design parameters, as well as the intraoperatively applied assembly forces, have been proposed to affect corrosion. Fretting corrosion is related to relative interface shear motion and fluid ingress, which may vary with contact force and area. It was hypothesised in this study that assembly forces modify the extent and distribution of the surface contact area at the taper interface between a cobalt chrome head and titanium stem taper with a standard threaded surface profile. Local abrasion of a thin gold coating applied to the stem taper prior to assembly was used to determine the contact area after disassembly. Profilometry was then used to assess permanent deformation of the stem taper surface profile. With increasing assembly force (500 N, 2000 N, 4000 N and 8000 N) the number of stem taper surface profile ridges in contact with the head taper was found to increase (9.2±9.3%, 65.4±10.8%, 92.8±6.0% and 100%) and the overall taper area in contact was also found to increase (0.6±0.7%, 5.5±1.0%, 9.9±1.1% and 16.1±0.9%). Contact was inconsistently distributed over the length of the taper. An increase in plastic radial deformation of the surface ridges (-0.05±0.14 μm, 0.1±0.14 μm, 0.21±0.22 μm and 0.96±0.25 μm) was also observed with increasing assembly force. The limited contact of the taper surface ridges at lower assembly forces may influence corrosion rates, suggesting that the magnitude of the assembly force may affect clinical outcome. The method presented provides a simple and practical assessment of the contact area at the taper interface.

  13. Miscellaneous conditions of tendons, tendon sheaths, and ligaments.

    Science.gov (United States)

    Dyson, S J; Dik, K J

    1995-08-01

    The use of diagnostic ultrasonography has greatly enhances our ability to diagnose injuries of tendons and tendon sheaths that were previously either unrecognized or poorly understood. For may of these injuries, there is currently only a small amount of follow-up data. This article considers injuries of the deep digital flexor tendon and its accessory ligament, the carpal tunnel syndrome soft tissue swellings on the dorsal aspect of the carpus, intertubercular (bicipital) bursitis and bicipital tendinitis, injuries of the gastrocnemius tendon, common calcaneal tendinitis, rupture of peroneus (fibularis tertius) and ligaments injuries of the back.

  14. [Successive ruptures of patellar and Achilles tendons. Anabolic steroids in competitive sports].

    Science.gov (United States)

    Isenberg, J; Prokop, A; Skouras, E

    2008-01-01

    Derivatives of testosterone or of 19-nor-testosterone are used as anabolics for the purpose of improving performance although the effect of anabolics is known still to be under discussion. The use of anabolic steroids continues among competitive athletes despite increased controls and increasingly frequent dramatic incidents connected with them. Whereas metabolic dysfunction during anabolic use is well documented, ruptures of the large tendons are rarely reported. Within 18 months, a 29-year-old professional footballer needed surgery for rupture of the patellar tendon and of both Achilles tendons. Carefully directed questioning elicited confirmation that he had taken different anabolic steroids regularly for 3 years with the intention of improving his strength. After each operation anabolic steroids were taken again at a high dosage during early convalescence and training. Minimally invasive surgery and open suturing techniques led to complete union of the Achilles tendons in good time. Training and anabolic use (metenolon 300 mg per week) started early after suturing of the patellar tendon including bone tunnels culminated in histologically confirmed rerupture after 8 weeks. After a ligament reconstruction with a semitendinosus tendon graft with subsequent infection, the tendon and reserve traction apparatus were lost. Repeated warnings of impaired healing if anabolic use was continued had been given without success. In view of the high number of unrecorded cases in competitive and athletic sports, we can assume that the use of anabolic steroids is also of quantitative relevance in the operative treatment of tendon ruptures.

  15. Effect of water on piezoelectricity in bone and collagen.

    Science.gov (United States)

    Netto, T G; Zimmerman, R L

    1975-01-01

    Interferometric measurements of bovine bone and tendon show that the values of the piezoelectric strain constant d14 decrease with hydration from the dry values of 0.2 X 10(-14) and 2.0 X 10(-14) m/V, respectively. The decrease of piezoelectricity in tendon is exponential with a characteristic hydration of 7% by weight from which an upper limit of the average molecular weight of the responsible electric dipole moments is deduced. The piezoelectricity in bone decreases relatively slowly with hydration indicating that the electric dipoles in bone collagen are subject to a different cancelling mechanism. PMID:1148359

  16. A singular perturbation limit of diffused interface energy with a fixed contact angle condition

    OpenAIRE

    Kagaya, Takashi; Tonegawa, Yoshihiro

    2016-01-01

    We study a general asymptotic behavior of critical points of a diffused interface energy with a fixed contact angle condition defined on a domain $\\Omega \\subset \\mathbb{R}^n$. We show that the limit varifold derived from the diffused energy satisfies a generalized contact angle condition on the boundary under a set of assumptions.

  17. X-ray phase contrast imaging of the bone-cartilage interface

    International Nuclear Information System (INIS)

    Ismail, Elna Che; Kaabar, W.; Garrity, D.; Gundogdu, O.; Bunk, O.; Pfeiffer, F.; Farquharson, M.J.; Bradley, D.A.

    2010-01-01

    Synovial joints articulate in a lubricating environment, the system providing for smooth articulation. The articular cartilage overlying the bone consists of a network of collagen fibres. This network is essential to cartilage integrity, suffering damage in degenerative joint disease such as osteoarthritis. At Surrey and also in work conducted by this group at the Paul Scherrer Institute (PSI) synchrotron site we have been applying a number of techniques to study the bone-cartilage interface and of changes occurring in this with disease. One of the techniques attracting particular interest is X-ray phase contrast imaging, yielding information on anatomical features that manifest from the large scale organisation of collagen and the mineralised phase contained within the collagen fibres in the deep cartilage zone. This work briefly reviews some of the basic supporting physics of X-ray phase contrast imaging and then shows example images of the articular surface and subchondral bone and other supporting results obtained to-date. Present results have been obtained on sections of bone not displaying evidence of an osteoarthritic lesion and can be used as a baseline against which diseased bone can be compared.

  18. X-ray phase contrast imaging of the bone-cartilage interface

    Energy Technology Data Exchange (ETDEWEB)

    Ismail, Elna Che; Kaabar, W.; Garrity, D.; Gundogdu, O. [Department of Physics, University of Surrey, Guildford GU2 7XH (United Kingdom); Bunk, O. [Paul Scherrer Institut, CH-5232 Villigen (Switzerland); Pfeiffer, F. [Paul Scherrer Institut, CH-5232 Villigen (Switzerland); Ecole Polytechnique Federale de Lausanne, CH-1015 Lausanne (Switzerland); Farquharson, M.J. [Department of Radiography, City University, London EC1V OHB (United Kingdom); Bradley, D.A. [Department of Physics, University of Surrey, Guildford GU2 7XH (United Kingdom)], E-mail: d.a.bradley@surrey.ac.uk

    2010-04-15

    Synovial joints articulate in a lubricating environment, the system providing for smooth articulation. The articular cartilage overlying the bone consists of a network of collagen fibres. This network is essential to cartilage integrity, suffering damage in degenerative joint disease such as osteoarthritis. At Surrey and also in work conducted by this group at the Paul Scherrer Institute (PSI) synchrotron site we have been applying a number of techniques to study the bone-cartilage interface and of changes occurring in this with disease. One of the techniques attracting particular interest is X-ray phase contrast imaging, yielding information on anatomical features that manifest from the large scale organisation of collagen and the mineralised phase contained within the collagen fibres in the deep cartilage zone. This work briefly reviews some of the basic supporting physics of X-ray phase contrast imaging and then shows example images of the articular surface and subchondral bone and other supporting results obtained to-date. Present results have been obtained on sections of bone not displaying evidence of an osteoarthritic lesion and can be used as a baseline against which diseased bone can be compared.

  19. Controllable Electrical Contact Resistance between Cu and Oriented-Bi2Te3 Film via Interface Tuning.

    Science.gov (United States)

    Kong, Xixia; Zhu, Wei; Cao, Lili; Peng, Yuncheng; Shen, Shengfei; Deng, Yuan

    2017-08-02

    The contact resistance between metals and semiconductors has become critical for the design of thin-film thermoelectric devices with their continuous miniaturization. Herein, we report a novel interface tuning method to regulate the contact resistance at the Bi 2 Te 3 -Cu interface, and three Bi 2 Te 3 films with different oriented microstructures are obtained. The lowest contact resistivity (∼10 -7 Ω cm 2 ) is observed between highly (00l) oriented Bi 2 Te 3 and Cu film, nearly an order of magnitude lower than other orientations. This significant decrease of contact resistivity is attributed to the denser film connections, lower lattice misfit, larger effective conducting contact area, and smaller width of the surface depletion region. Meanwhile, our results show that the reduction of contact resistance has little dependence on the interfacial diffusion based on the little change in contact resistivity after the introduction of an effective Ti barrier layer. Our work provides a new idea for the mitigation of contact resistivity in thin-film thermoelectric devices and also gives certain guidance for the size design of the next-level miniaturized devices.

  20. Tendoscopic Double-Row Suture Bridge Peroneal Retinaculum Repair for Recurrent Dislocation of Peroneal Tendons in the Ankle.

    Science.gov (United States)

    Nishimura, Akinobu; Nakazora, Shigeto; Ito, Naoya; Fukuda, Aki; Kato, Ko; Sudo, Akihiro

    2016-06-01

    Traumatic dislocation of peroneal tendons in the ankle is an uncommon lesion that mainly affects young adults. Unfortunately, most cases lead to recurrent dislocation of the peroneal tendons of the ankle (RPTD). Therefore, most cases need operative treatment. One of the most common operative procedures is superior peroneal retinaculum (SPR) repair. Recently, surgery for RPTD has been achieved with less invasive arthroscopic procedures. In this article, tendoscopic surgery for RPTD using a double-row suture bridge technique is introduced. This technique consists of debridement of the lateral aspect of the fibula under an intrasheath pseudo-cavity, suture anchor insertion into the fibular ridge, and reattachment of the SPR to the fibula using a knotless anchor screwed into the lateral aspect of the fibula. This technique mimics the double-row suture bridge technique for rotator cuff tear repair. The double-row suture bridge technique requires more surgical steps than the single-row technique, but it provides a wider bone-SPR contact surface and tighter fixation than the single-row technique. This procedure is an attractive option because it is less invasive and has achieved results similar to open procedures.

  1. Chemical and structural analysis of the bone-implant interface by TOF-SIMS, SEM, FIB and TEM: Experimental study in animal

    International Nuclear Information System (INIS)

    Palmquist, Anders; Emanuelsson, Lena; Sjövall, Peter

    2012-01-01

    Although bone-anchored implants are widely used in reconstructive medicine, the mechanism of osseointegration is still not fully understood. Novel analytical tools are needed to further understand this process, where both the chemical and structural aspects of the bone-implant interface are important. The aim of this study was to evaluate the advantages of combining time-of-flight secondary ion mass spectroscopy (TOF-SIMS) with optical (LM), scanning (SEM) and transmission electron microscopy (TEM) techniques for studying the bone-implant interface of bone-anchored implants. Laser-modified titanium implants with surrounded bone retrieved after 8 weeks healing in rabbit were dehydrated and resin embedded. Three types of sample preparation were studied to evaluate the information gained by combining TOF-SIMS, SEM, FIB and TEM. The results show that imaging TOF-SIMS can provide detailed chemical information, which in combination with structural information from microscopy methods provide a more complete characterization of anatomical structures at the bone-implant interface. By investigating various sample preparation techniques, it is shown that grinded cross section samples can be used for chemical imaging using TOF-SIMS, if careful consideration of potential preparation artifacts is taken into account. TOF-SIMS analysis of FIB-prepared bone/implant cross section samples show distinct areas corresponding to bone tissue and implant with a sharp interface, although without chemical information about the organic components.

  2. Anatomic factors related to the cause of tennis elbow.

    Science.gov (United States)

    Bunata, Robert E; Brown, David S; Capelo, Roderick

    2007-09-01

    The pathogenesis of lateral epicondylitis remains unclear. Our purpose was to study the anatomy of the lateral aspect of the elbow under static and dynamic conditions in order to identify bone-to-tendon and tendon-to-tendon contact or rubbing that might cause abrasion of the tissues. Eighty-five cadaveric elbows were examined to determine details related to the bone structure and musculotendinous origins. We identified the relative positions of the musculotendinous units and the underlying bone when the elbow was in different degrees of flexion. We also recorded the contact between the extensor carpi radialis brevis and the lateral edge of the capitellum as elbow motion occurred, and we sought to identify the areas of the capitellum and extensor carpi radialis brevis where contact occurs. The average site of origin of the extensor carpi radialis brevis on the humerus lay slightly medial and superior to the outer edge of the capitellum. As the elbow was extended, the undersurface of the extensor carpi radialis brevis rubbed against the lateral edge of the capitellum while the extensor carpi radialis longus compressed the brevis against the underlying bone. The extensor carpi radialis brevis tendon has a unique anatomic location that makes its undersurface vulnerable to contact and abrasion against the lateral edge of the capitellum during elbow motion.

  3. Effect of healing time on bone-implant contact of orthodontic micro-implants: a histologic study.

    Science.gov (United States)

    Ramazanzadeh, Barat Ali; Fatemi, Kazem; Dehghani, Mahboobe; Mohtasham, Nooshin; Jahanbin, Arezoo; Sadeghian, Hamed

    2014-01-01

    Objectives. This study aimed to evaluate the effect of immediate and delayed loading of orthodontic micro-implants on bone-implant contact. Materials and Methods. Sixty four micro-implants were implanted in dog's jaw bone. The micro-implants were divided into loaded and unloaded (control) groups. The control group had two subgroups: four and eight weeks being implanted. The loaded group had two subgroups of immediate loading and delayed (after four weeks healing) loading. Loaded samples were subjected to 200g load for four weeks. After sacrificing the animals micro-implants and surrounding tissues were observed histologically. Bone-implant contact ratios (BIC) were calculated and different groups' results were compared by three-way ANOVA. Results. Mean survival rate was 96.7% in general. Survival rates were 96.7%, 94.4% and 100% for control, immediate and delayed loaded groups, respectively. BIC values were not significantly different in loaded and control groups, immediate and delayed loading groups, and pressure and tension sides. Mandibular micro-implants had significantly higher BIC than maxillary ones in immediate loading, 4-weeks control, and 8-weeks control groups (P = 0.021, P = 0.009, P = 0.003, resp.). Conclusion Immediate or delayed loading of micro-implants in dog did not cause significant difference in Bone-implant contact which could be concluded that healing time had not significant effect on micro-implant stability.

  4. Bismuth nanowire growth under low deposition rate and its ohmic contact free of interface damage

    Directory of Open Access Journals (Sweden)

    Ye Tian

    2012-03-01

    Full Text Available High quality bismuth (Bi nanowire and its ohmic contact free of interface damage are quite desired for its research and application. In this paper, we propose one new way to prepare high-quality single crystal Bi nanowires at a low deposition rate, by magnetron sputtering method without the assistance of template or catalyst. The slow deposition growth mechanism of Bi nanowire is successfully explained by an anisotropic corner crossing effect, which is very different from existing explanations. A novel approach free of interface damage to ohmic contact of Bi nanowire is proposed and its good electrical conductivity is confirmed by I-V characteristic measurement. Our method provides a quick and convenient way to produce high-quality Bi nanowires and construct ohmic contact for desirable devices.

  5. Influence of simulated bone-implant contact and implant diameter on secondary stability: a resonance frequency in vitro study.

    Science.gov (United States)

    Veltri, Mario; González-Martín, Oscar; Belser, Urs C

    2014-08-01

    This study tested the hypothesis of no differences in resonance frequency for standardized amounts of simulated bone-implant contact around implants with different diameters. In addition, it was evaluated if resonance frequency is able to detect a difference between stable and rotation mobile ("spinning") implants. Implants with diameters of 3.3, 4.1 and 4.8 mm were placed in a purposely designed metal mould where liquid polyurethane resin was then poured to obtain a simulated bone-implant specimen. By regulating the mould, it was possible to create the following simulated bone-implant contact groups: 3.3 mm (198.6 mm(2)); 4.1 mm (198.8 mm(2)); 4.8 mm (200.2 mm(2)); 4.8 mm (231.7 mm(2)); 4.8 mm (294.7 mm(2)). Each group included 10 specimens. After resin setting, resonance frequency was measured. On the last group, measurements were repeated after establishing implant rotational mobility. One-way ANOVA tests with post hoc comparisons, a Pearson's correlation coefficient and a t-test for repeated measurements were used to evaluate statistically significant differences. Implants with different diameters but with the same amount of simulated osseointegration revealed no differences in resonance frequency. On the contrary, an increase of simulated bone-implant contact resulted in significantly higher resonance frequency. A clear direct linear correlation resulted between resonance frequency and simulated bone-implant contact. Furthermore, a significant difference resulted between resonance frequency measured before and after creation of rotational mobility. Within the conditions of this study, the secondary stability was correlated with the simulated bone-implant contact. In addition, resonance frequency was able to discern between stable and rotation mobile implants. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  6. Optimizing a micro-computed tomography-based surrogate measurement of bone-implant contact.

    Science.gov (United States)

    Meagher, Matthew J; Parwani, Rachna N; Virdi, Amarjit S; Sumner, Dale R

    2018-03-01

    Histology and backscatter scanning electron microscopy (bSEM) are the current gold standard methods for quantifying bone-implant contact (BIC), but are inherently destructive. Microcomputed tomography (μCT) is a non-destructive alternative, but attempts to validate μCT-based assessment of BIC in animal models have produced conflicting results. We previously showed in a rat model using a 1.5 mm diameter titanium implant that the extent of the metal-induced artefact precluded accurate measurement of bone sufficiently close to the interface to assess BIC. Recently introduced commercial laboratory μCT scanners have smaller voxels and improved imaging capabilities, possibly overcoming this limitation. The goals of the present study were to establish an approach for optimizing μCT imaging parameters and to validate μCT-based assessment of BIC. In an empirical parametric study using a 1.5 mm diameter titanium implant, we determined 90 kVp, 88 µA, 1.5 μm isotropic voxel size, 1600 projections/180°, and 750 ms integration time to be optimal. Using specimens from an in vivo rat experiment, we found significant correlations between bSEM and μCT for BIC with the manufacturer's automated analysis routine (r = 0.716, p = 0.003) or a line-intercept method (r = 0.797, p = 0.010). Thus, this newer generation scanner's improved imaging capability reduced the extent of the metal-induced artefact zone enough to permit assessment of BIC. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:979-986, 2018. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  7. The biomechanical effects of limb lengthening and botulinum toxin type A on rabbit tendon.

    Science.gov (United States)

    Olabisi, Ronke M; Best, Thomas M; Hurschler, Christof; Vanderby, Ray; Noonan, Kenneth J

    2010-12-01

    Numerous studies have examined the effects of distraction osteogenesis (DO) on bone, but relatively fewer have explored muscle adaptation, and even less have addressed the concomitant alterations that occur in the tendon. The purpose herein was to characterize the biomechanical properties of normal and elongated rabbit (N = 20) tendons with and without prophylactic botulinum toxin type A (BTX-A) treatment. Elastic and viscoelastic properties of Achilles and Tibialis anterior (TA) tendons were evaluated through pull to failure and stress relaxation tests. All TA tendons displayed nonlinear viscoelastic responses that were strain dependent. A power law formulation was used to model tendon viscoelastic responses and tendon elastic responses were fit with a microstructural model. Distraction-elongated tendons displayed increases in compliance and stress relaxation rates over undistracted tendons; BTX-A administration offset this result. The elastic moduli of distraction-lengthened TA tendons were diminished (p = 0.010) when distraction was combined with gastrocnemius (GA) BTX-A administration, elastic moduli were further decreased (p = 0.004) and distraction following TA BTX-A administration resulted in TA tendons with moduli not different from contralateral control (p > 0.05). Compared to contralateral control, distraction and GA BTX-A administration displayed shortened toe regions, (p = 0.031 and 0.038, respectively), while tendons receiving BTX-A in the TA had no differences in the toe region (p > 0.05). Ultimate tensile stress was unaltered by DO, but stress at the transition from the toe to the linear region of the stress-stretch curve was diminished in all distraction-elongated TA tendons (p properties. Copyright © 2010 Elsevier Ltd. All rights reserved.

  8. Experimental and numerical study of cemented bone-implant interface behaviour

    Czech Academy of Sciences Publication Activity Database

    Kytýř, Daniel; Doktor, Tomáš; Jiroušek, Ondřej; Zlámal, Petr; Pokorný, D.

    2011-01-01

    Roč. 15, č. 15 (2011), s. 5-13 ISSN 1971-8993 R&D Projects: GA ČR(CZ) GAP105/10/2305 Institutional research plan: CEZ:AV0Z20710524 Keywords : bone-cement interface * computed tomography * hip simulator * crack detection Subject RIV: FI - Traumatology, Orthopedics http://www.gruppofrattura.it/index.php?option=com_content&task=view&id=90&Itemid=284

  9. Volumetric quantification of bone-implant contact using micro-computed tomography analysis based on region-based segmentation

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Sung Won; Lee, Woo Jin; Choi, Soon Chul; Lee, Sam Sun; Heo, Min Suk; Huh, Kyung Hoe; Kim, Tae Il; Yi, Won Ji [Dental Research Institute, School of Dentistry, Seoul National University, Seoul (Korea, Republic of)

    2015-03-15

    We have developed a new method of segmenting the areas of absorbable implants and bone using region-based segmentation of micro-computed tomography (micro-CT) images, which allowed us to quantify volumetric bone-implant contact (VBIC) and volumetric absorption (VA). The simple threshold technique generally used in micro-CT analysis cannot be used to segment the areas of absorbable implants and bone. Instead, a region-based segmentation method, a region-labeling method, and subsequent morphological operations were successively applied to micro-CT images. The three-dimensional VBIC and VA of the absorbable implant were then calculated over the entire volume of the implant. Two-dimensional (2D) bone-implant contact (BIC) and bone area (BA) were also measured based on the conventional histomorphometric method. VA and VBIC increased significantly with as the healing period increased (p<0.05). VBIC values were significantly correlated with VA values (p<0.05) and with 2D BIC values (p<0.05). It is possible to quantify VBIC and VA for absorbable implants using micro-CT analysis using a region-based segmentation method.

  10. Volumetric quantification of bone-implant contact using micro-computed tomography analysis based on region-based segmentation

    International Nuclear Information System (INIS)

    Kang, Sung Won; Lee, Woo Jin; Choi, Soon Chul; Lee, Sam Sun; Heo, Min Suk; Huh, Kyung Hoe; Kim, Tae Il; Yi, Won Ji

    2015-01-01

    We have developed a new method of segmenting the areas of absorbable implants and bone using region-based segmentation of micro-computed tomography (micro-CT) images, which allowed us to quantify volumetric bone-implant contact (VBIC) and volumetric absorption (VA). The simple threshold technique generally used in micro-CT analysis cannot be used to segment the areas of absorbable implants and bone. Instead, a region-based segmentation method, a region-labeling method, and subsequent morphological operations were successively applied to micro-CT images. The three-dimensional VBIC and VA of the absorbable implant were then calculated over the entire volume of the implant. Two-dimensional (2D) bone-implant contact (BIC) and bone area (BA) were also measured based on the conventional histomorphometric method. VA and VBIC increased significantly with as the healing period increased (p<0.05). VBIC values were significantly correlated with VA values (p<0.05) and with 2D BIC values (p<0.05). It is possible to quantify VBIC and VA for absorbable implants using micro-CT analysis using a region-based segmentation method.

  11. Electron-selective contacts via ultra-thin organic interface dipoles for silicon organic heterojunction solar cells

    Science.gov (United States)

    Reichel, Christian; Würfel, Uli; Winkler, Kristina; Schleiermacher, Hans-Frieder; Kohlstädt, Markus; Unmüssig, Moritz; Messmer, Christoph A.; Hermle, Martin; Glunz, Stefan W.

    2018-01-01

    In the last years, novel materials for the formation of electron-selective contacts on n-type crystalline silicon (c-Si) heterojunction solar cells were explored as an interfacial layer between the metal electrode and the c-Si wafer. Besides inorganic materials like transition metal oxides or alkali metal fluorides, also interfacial layers based on organic molecules with a permanent dipole moment are promising candidates to improve the contact properties. Here, the dipole effect plays an essential role in the modification of the interface and effective work function of the contact. The amino acids L-histidine, L-tryptophan, L-phenylalanine, glycine, and sarcosine, the nucleobase adenine, and the heterocycle 4-hydroxypyridine were investigated as dipole materials for an electron-selective contact on the back of p- and n-type c-Si with a metal electrode based on aluminum (Al). Furthermore, the effect of an added fluorosurfactant on the resulting contact properties was examined. The performance of n-type c-Si solar cells with a boron diffusion on the front was significantly increased when L-histidine and/or the fluorosurfactant was applied as a full-area back surface field. This improvement was attributed to the modification of the interface and the effective work function of the contact by the dipole material which was corroborated by numerical device simulations. For these solar cells, conversion efficiencies of 17.5% were obtained with open-circuit voltages (Voc) of 625 mV and fill factors of 76.3%, showing the potential of organic interface dipoles for silicon organic heterojunction solar cells due to their simple formation by solution processing and their low thermal budget requirements.

  12. Micro-mechanical modeling of the cement-bone interface: the effect of friction, morphology and material properties on the micromechanical response.

    NARCIS (Netherlands)

    Janssen, D.; Mann, K.A.; Verdonschot, N.J.J.

    2008-01-01

    In order to gain insight into the micro-mechanical behavior of the cement-bone interface, the effect of parametric variations of frictional, morphological and material properties on the mechanical response of the cement-bone interface were analyzed using a finite element approach. Finite element

  13. Micro-mechanical modeling of the cement-bone interface: the effect of friction morphology and material properties on the micromechanical response

    NARCIS (Netherlands)

    Janssen, Dennis; Mann, Kenneth A.; Verdonschot, Nicolaas Jacobus Joseph

    2008-01-01

    In order to gain insight into the micro-mechanical behavior of the cement–bone interface, the effect of parametric variations of frictional, morphological and material properties on the mechanical response of the cement–bone interface were analyzed using a finite element approach. Finite element

  14. Inhibition of 5-LOX, COX-1, and COX-2 increases tendon healing and reduces muscle fibrosis and lipid accumulation after rotator cuff repair.

    Science.gov (United States)

    Oak, Nikhil R; Gumucio, Jonathan P; Flood, Michael D; Saripalli, Anjali L; Davis, Max E; Harning, Julie A; Lynch, Evan B; Roche, Stuart M; Bedi, Asheesh; Mendias, Christopher L

    2014-12-01

    of a stable bone-tendon interface, although decreases in muscle fiber specific force production were observed, and force production in fact declined. This study demonstrates that the inhibition of 5-LOX, COX-1, and COX-2 modulates the healing process of repaired rotator cuff tendons. Although further studies are necessary, the treatment of patients with licofelone after cuff repair may improve the development of a stable enthesis and enhance postoperative outcomes. © 2014 The Author(s).

  15. Open extensor tendon injuries: an epidemiologic study.

    Science.gov (United States)

    Patillo, Dominic; Rayan, Ghazi M

    2012-01-01

    To report the epidemiology, mechanism, anatomical location, distribution, and severity of open extensor tendon injuries in the digits, hand, and forearm as well as the frequency of associated injuries to surrounding bone and soft tissue. Retrospective chart review was conducted for patients who had operative repair of open digital extensor tendon injuries in all zones within an 11-year period. Data was grouped according to patient characteristics, zone of injury, mechanism of injury, and presence of associated injury. Statistical analysis was used to determine the presence of relevant associations. Eighty-six patients with 125 severed tendons and 105 injured digits were available for chart reviews. Patients were predominantly males (83%) with a mean age of 34.2 years and the dominant extremity was most often injured (60%). The thumb was the most commonly injured (25.7%), followed by middle finger (24.8), whereas small finger was least affected (10.5%). Sharp laceration was the most common mechanism of injury (60%), and most of these occurred at or proximal to the metacarpophalangeal joints. Most saw injuries occurred distal to the metacarpophalangeal joint. Zone V was the most commonly affected in the fingers (27%) while zone VT was the most commonly affected in the thumb (69%). Associated injuries to bone and soft tissue occurred in 46.7% of all injuries with saw and crush/avulsions being predictive of fractures and damage to the underlying joint capsule. The extensor mechanism is anatomically complex, and open injuries to the dorsum of the hand, wrist, and forearm, especially of crushing nature and those inflicted by saws, must be thoroughly evaluated. Associated injuries should be ruled out in order to customize surgical treatment and optimize outcome.

  16. FIBRILLINS IN TENDON

    Directory of Open Access Journals (Sweden)

    Betti Giusti

    2016-10-01

    Full Text Available Tendons among connective tissue, mainly collagen, contain also elastic fibres made of fibrillin 1, fibrillin 2 and elastin that are broadly distributed in tendons and represent 1-2% of the dried mass of the tendon. Only in the last years, studies on structure and function of elastic fibres in tendons have been performed. Aim of this review is to revise data on the organization of elastic fibres in tendons, in particular fibrillin structure and function, and on the clinical manifestations associated to alterations of elastic fibres in tendons. Indeed, microfibrils may contribute to tendon mechanics; therefore, their alterations may cause joint hypermobility and contractures which have been found to be clinical features in patients with Marfan syndrome and Beals syndrome. The two diseases are caused by mutations in genes FBN1 and FBN2 encoding fibrillin 1 and fibrillin 2, respectively.

  17. Compositional and structural studies of the bone-cartilage interface using PIXE and SAXS techniques

    Energy Technology Data Exchange (ETDEWEB)

    Kaabar, W., E-mail: W.kaabar@surrey.ac.u [Department of Physics, University of Surrey, Guildford, GU2 7XH (United Kingdom); Laklouk, A. [Al-Fateh University, Tripoli-Libya (Libyan Arab Jamahiriya); Bunk, O. [Swiss Light Source, Paul Scherrer Institute, 5232 Villigen (Switzerland); Baily, M. [Department of Medical Physics and Applied Radiation Sciences, McMaster University, 1280 Main Street West, Hamilton, Ontario, Canada, L8S 4K1 (Canada); Farquharson, M.J. [Surrey Ion Beam Centre, University of Surrey, Guildford, GU2 7XH (United Kingdom); Bradley, David [Department of Physics, University of Surrey, Guildford, GU2 7XH (United Kingdom)

    2010-07-21

    Micro-proton-induced X-ray emission ({mu}-PIXE) analysis has been employed in investigating the presence of number of essential anions and cations in thin sections of diseased human articular cartilage affected by osteoarthritis (OA). Distribution maps for Ca, P, K and S in diseased sections show marked alterations in the concentrations of these at the bone-cartilage interface compared to normal tissue. For a decalcified section of human articular cartilage, organisational changes of the collagen network were investigated by small-angle X-ray scattering (SAXS). The established gradual reorientation of collagen fibres from vertical to the surface of the joint to normal to the bone-cartilage interface is observed to be heavily disrupted in OA.

  18. Compositional and structural studies of the bone-cartilage interface using PIXE and SAXS techniques

    International Nuclear Information System (INIS)

    Kaabar, W.; Laklouk, A.; Bunk, O.; Baily, M.; Farquharson, M.J.; Bradley, David

    2010-01-01

    Micro-proton-induced X-ray emission (μ-PIXE) analysis has been employed in investigating the presence of number of essential anions and cations in thin sections of diseased human articular cartilage affected by osteoarthritis (OA). Distribution maps for Ca, P, K and S in diseased sections show marked alterations in the concentrations of these at the bone-cartilage interface compared to normal tissue. For a decalcified section of human articular cartilage, organisational changes of the collagen network were investigated by small-angle X-ray scattering (SAXS). The established gradual reorientation of collagen fibres from vertical to the surface of the joint to normal to the bone-cartilage interface is observed to be heavily disrupted in OA.

  19. Low-Magnitude, High-Frequency Vibration Fails to Accelerate Ligament Healing but Stimulates Collagen Synthesis in the Achilles Tendon.

    Science.gov (United States)

    Thompson, William R; Keller, Benjamin V; Davis, Matthew L; Dahners, Laurence E; Weinhold, Paul S

    2015-05-01

    Low-magnitude, high-frequency vibration accelerates fracture and wound healing and prevents disuse atrophy in musculoskeletal tissues. To investigate the role of low-magnitude, high-frequency vibration as a treatment to accelerate healing of an acute ligament injury and to examine gene expression in the intact Achilles tendon of the injured limb after low-magnitude, high-frequency vibration. Controlled laboratory study. Complete surgical transection of the medial collateral ligament (MCL) was performed in 32 Sprague-Dawley rats, divided into control and low-magnitude, high-frequency vibration groups. Low-magnitude, high-frequency vibration started on postoperative day 2, and rats received vibration for 30 minutes a day for 12 days. All rats were sacrificed 2 weeks after the operation, and their intact and injured MCLs were biomechanically tested or used for histological analysis. Intact Achilles tendons from the injured limb were evaluated for differences in gene expression. Mechanical testing revealed no differences in the ultimate tensile load or the structural stiffness between the control and vibration groups for either the injured or intact MCL. Vibration exposure increased gene expression of collagen 1 alpha (3-fold), interleukin 6 (7-fold), cyclooxygenase 2 (5-fold), and bone morphogenetic protein 12 (4-fold) in the intact Achilles tendon when compared with control tendons ( P frequency vibration treatment, significant enhancements in gene expression were observed in the intact Achilles tendon. These included collagen, several inflammatory cytokines, and growth factors critical for tendons. As low-magnitude, high-frequency vibration had no negative effects on ligament healing, vibration therapy may be a useful tool to accelerate healing of other tissues (bone) in multitrauma injuries without inhibiting ligament healing. Additionally, the enhanced gene expression in response to low-magnitude, high-frequency vibration in the intact Achilles tendon suggests the

  20. Characterization of the bone-metal implant interface by Digital Volume Correlation of in-situ loading using neutron tomography.

    Science.gov (United States)

    Le Cann, Sophie; Tudisco, Erika; Perdikouri, Christina; Belfrage, Ola; Kaestner, Anders; Hall, Stephen; Tägil, Magnus; Isaksson, Hanna

    2017-11-01

    Metallic implants are commonly used as surgical treatments for many orthopedic conditions. The long-term stability of implants relies on an adequate integration with the surrounding bone. Unsuccessful integration could lead to implant loosening. By combining mechanical loading with high-resolution 3D imaging methods, followed by image analysis such as Digital Volume Correlation (DVC), we aim at evaluating ex vivo the mechanical resistance of newly formed bone at the interface. X-rays tomography is commonly used to image bone but induces artefacts close to metallic components. Utilizing a different interaction with matter, neutron tomography is a promising alternative but has not yet been used in studies of bone mechanics. This work demonstrates that neutron tomography during in situ loading is a feasible tool to characterize the mechanical response of bone-implant interfaces, especially when combined with DVC. Experiments were performed where metal screws were implanted in rat tibiae during 4 weeks. The screws were pulled-out while the samples were sequentially imaged in situ with neutron tomography. The images were analyzed to quantify bone ingrowth around the implants. DVC was used to track the internal displacements and calculate the strain fields in the bone during loading. The neutron images were free of metal-related artefacts, which enabled accurate quantification of bone ingrowth on the screw (ranging from 60% to 71%). DVC allowed successful identification of the deformation and cracks that occurred during mechanical loading and led to final failure of the bone-implant interface. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Prediction of bead area contact load at the tire-wheel interface using NASTRAN

    Science.gov (United States)

    Chen, C. H. S.

    1982-01-01

    The theoretical prediction of the bead area contact load at the tire wheel interface using NASTRAN is reported. The application of the linear code to a basically nonlinear problem results in excessive deformation of the structure and the tire-wheel contact conditions become impossible to achieve. A psuedo-nonlinear approach was adopted in which the moduli of the cord reinforced composite are increased so that the computed key deformations matched that of the experiment. Numerical results presented are discussed.

  2. Active Achilles tendon kinesitherapy accelerates Achilles tendon repair by promoting neurite regeneration.

    Science.gov (United States)

    Jielile, Jiasharete; Aibai, Minawa; Sabirhazi, Gulnur; Shawutali, Nuerai; Tangkejie, Wulanbai; Badelhan, Aynaz; Nuerduola, Yeermike; Satewalede, Turde; Buranbai, Darehan; Hunapia, Beicen; Jialihasi, Ayidaer; Bai, Jingping; Kizaibek, Murat

    2012-12-15

    Active Achilles tendon kinesitherapy facilitates the functional recovery of a ruptured Achilles tendon. However, protein expression during the healing process remains a controversial issue. New Zealand rabbits, aged 14 weeks, underwent tenotomy followed immediately by Achilles tendon microsurgery to repair the Achilles tendon rupture. The tendon was then immobilized or subjected to postoperative early motion treatment (kinesitherapy). Mass spectrography results showed that after 14 days of motion treatment, 18 protein spots were differentially expressed, among which, 12 were up-regulated, consisting of gelsolin isoform b and neurite growth-related protein collapsing response mediator protein 2. Western blot analysis showed that gelsolin isoform b was up-regulated at days 7-21 of motion treatment. These findings suggest that active Achilles tendon kinesitherapy promotes the neurite regeneration of a ruptured Achilles tendon and gelsolin isoform b can be used as a biomarker for Achilles tendon healing after kinesitherapy.

  3. Active Achilles tendon kinesitherapy accelerates Achilles tendon repair by promoting neurite regeneration☆

    Science.gov (United States)

    Jielile, Jiasharete; Aibai, Minawa; Sabirhazi, Gulnur; Shawutali, Nuerai; Tangkejie, Wulanbai; Badelhan, Aynaz; Nuerduola, Yeermike; Satewalede, Turde; Buranbai, Darehan; Hunapia, Beicen; Jialihasi, Ayidaer; Bai, Jingping; Kizaibek, Murat

    2012-01-01

    Active Achilles tendon kinesitherapy facilitates the functional recovery of a ruptured Achilles tendon. However, protein expression during the healing process remains a controversial issue. New Zealand rabbits, aged 14 weeks, underwent tenotomy followed immediately by Achilles tendon microsurgery to repair the Achilles tendon rupture. The tendon was then immobilized or subjected to postoperative early motion treatment (kinesitherapy). Mass spectrography results showed that after 14 days of motion treatment, 18 protein spots were differentially expressed, among which, 12 were up-regulated, consisting of gelsolin isoform b and neurite growth-related protein collapsing response mediator protein 2. Western blot analysis showed that gelsolin isoform b was up-regulated at days 7–21 of motion treatment. These findings suggest that active Achilles tendon kinesitherapy promotes the neurite regeneration of a ruptured Achilles tendon and gelsolin isoform b can be used as a biomarker for Achilles tendon healing after kinesitherapy. PMID:25317130

  4. Patella tendon injuries secondary to cement spacers used at first-stage revision of infected total knee replacement

    Directory of Open Access Journals (Sweden)

    Wasim S Khan

    2015-04-01

    Full Text Available We describe a series of three patients who sustained patella tendon injuries in infected TKAs following the use of a static cement spacer at first-stage knee revision. The patella tendon injuries resulted in significant compromise to wound healing and knee stability requiring multiple surgeries. The mid-term function was poor with an Oxford score at 24 months ranging from 12-20. Based on our experience, we advise caution in the use of static cement spacer blocks. If they are to be used, we recommend that they should be keyed in the bone to prevent patella tendon injuries.

  5. In-vitro tensile testing machine for vibration study of fresh rabbit Achilles tendon

    Science.gov (United States)

    Revel, Gian M.; Scalise, Alessandro; Scalise, Lorenzo; Pianosi, Antonella

    2001-10-01

    A lot of people, overall athletic one suffer from tendinitis or complete rupture of the Achilles tendon. This structure becomes inflamed and damaged mainly from a variety of mechanical forces and sometimes due to metabolic problems, such as diabetes or arthritis. Over the past three decades extensive studies have been performed on the structural and mechanical properties of Achilles tendon trying to explain the constitutive equations to describe and foresee tendon behavior. Among the various mechanical parameters, the vibrational behavior is also of interest. Several investigations are performed in order to study how the Achilles tendon vibrations influence the response of the muscle proprioception and human posture. The present article describes how in vitro tensile experiments can be performed, taking into account the need to simulate physiological condition of Achilles tendon and thus approaching some opened problems in the design of the experimental set-up. A new system for evaluating tendon vibrations by non contact techniques is proposed. Preliminary simple elongation tests are made extracting the main mechanical parameters: stress and strain at different fixed stretches, in order to characterize the tissue. Finally, a vibration study is made at each pretensioned tendon level evaluating the oscillating curves caused by a small hammer.

  6. Contact-angle hysteresis on periodic microtextured surfaces: Strongly corrugated liquid interfaces.

    Science.gov (United States)

    Iliev, Stanimir; Pesheva, Nina

    2016-06-01

    We study numerically the shapes of a liquid meniscus in contact with ultrahydrophobic pillar surfaces in Cassie's wetting regime, when the surface is covered with identical and periodically distributed micropillars. Using the full capillary model we obtain the advancing and the receding equilibrium meniscus shapes when the cross-sections of the pillars are both of square and circular shapes, for a broad interval of pillar concentrations. The bending of the liquid interface in the area between the pillars is studied in the framework of the full capillary model and compared to the results of the heterogeneous approximation model. The contact angle hysteresis is obtained when the three-phase contact line is located on one row (block case) or several rows (kink case) of pillars. It is found that the contact angle hysteresis is proportional to the line fraction of the contact line on pillars tops in the block case and to the surface fraction for pillar concentrations 0.1-0.5 in the kink case. The contact angle hysteresis does not depend on the shape (circular or square) of the pillars cross-section. The expression for the proportionality of the receding contact angle to the line fraction [Raj et al., Langmuir 28, 15777 (2012)LANGD50743-746310.1021/la303070s] in the case of block depinning is theoretically substantiated through the capillary force, acting on the solid plate at the meniscus contact line.

  7. Proposal of Non-Contact Type Interface of Command Input Using Lip Motion Features

    Science.gov (United States)

    Sato, Yoshiyuki; Kageyama, Yoichi; Nishida, Makoto

    Lip motion features are of practical use in identifying individuals. It is therefore important to develop non-contact type interface. For the interface using lip motion features, individual differences such as accents and dialects in commands should be accepted. In this paper, we propose a method to identify commands by analyzing three kinds of lip motion features. They are lip width, lip length, and ratio of width and length. The analysis is made on the basis of these features' relative values obtained from the primary and object frame. The proposed method has three steps. First, we extracted the lip motion features on the basis of both positions and shapes of lip in each frame of facial images. Second, standard patterns were created from features of six utterances per command. The standard pattern is able to reduce the relative difference in the lip motion features. Third, similarities among commands were computed by Dynamic-Programming (DP) matching. And then, the command with the largest similarity was selected as the target one. Our experimental results suggest that proposed method is useful to construct the non-contact type interface of command input using lip motion features.

  8. Comparison of the surfaces and interfaces formed for sputter and electroless deposited gold contacts on CdZnTe

    Science.gov (United States)

    Bell, Steven J.; Baker, Mark A.; Duarte, Diana D.; Schneider, Andreas; Seller, Paul; Sellin, Paul J.; Veale, Matthew C.; Wilson, Matthew D.

    2018-01-01

    Cadmium zinc telluride (CdZnTe) is a leading sensor material for spectroscopic X/γ-ray imaging in the fields of homeland security, medical imaging, industrial analysis and astrophysics. The metal-semiconductor interface formed during contact deposition is of fundamental importance to the spectroscopic performance of the detector and is primarily determined by the deposition method. A multi-technique analysis of the metal-semiconductor interface formed by sputter and electroless deposition of gold onto (111) aligned CdZnTe is presented. Focused ion beam (FIB) cross section imaging, X-ray photoelectron spectroscopy (XPS) depth profiling and current-voltage (IV) analysis have been applied to determine the structural, chemical and electronic properties of the gold contacts. In a novel approach, principal component analysis has been employed on the XPS depth profiles to extract detailed chemical state information from different depths within the profile. It was found that electroless deposition forms a complicated, graded interface comprised of tellurium oxide, gold/gold telluride particulates, and cadmium chloride. This compared with a sharp transition from surface gold to bulk CdZnTe observed for the interface formed by sputter deposition. The electronic (IV) response for the detector with electroless deposited contacts was symmetric, but was asymmetric for the detector with sputtered gold contacts. This is due to the electroless deposition degrading the difference between the Cd- and Te-faces of the CdZnTe (111) crystal, whilst these differences are maintained for the sputter deposited gold contacts. This work represents an important step in the optimisation of the metal-semiconductor interface which currently is a limiting factor in the development of high resolution CdZnTe detectors.

  9. Intraoperative extracorporeal autogenous irradiated tendon grafts for functional limb salvage surgery of soft tissue sarcomas of the wrist and hand.

    Science.gov (United States)

    Omori, Shinsuke; Hamada, Kenichiro; Outani, Hidetatsu; Oshima, Kazuya; Joyama, Susumu; Tomita, Yasuhiko; Naka, Norifumi; Araki, Nobuhito; Yoshikawa, Hideki

    2015-05-12

    In patients with soft tissue sarcoma of the wrist and hand, limb salvage operation is extremely challenging for surgeons in attempting a complete tumor resection with negative surgical margins. In this study, we report four patients with soft tissue sarcoma of the wrist and hand treated by limb salvage operation with intraoperative extracorporeal autogenous irradiated tendon grafts. The patients were all male, and the mean age at the time of surgery was 45 years. Histological diagnoses included clear cell sarcoma in two patients, synovial sarcoma in one, and angiosarcoma in one. All four patients had high grade tumors, wherein three had American Joint Committee on Cancer (AJCC) stage III disease and one with AJCC stage IV disease. The tumors were resected en bloc with involved tendons. The tendons were isolated from the resected tissues, irradiated ex vivo, and re-implanted into the host tendons. In one patient, the bone was resected additionally because of tumor invasion to the bone. Hand function was evaluated using Musculoskeletal Tumor Society (MSTS) rating system. Of the four patients, three died of distant metastatic disease. The remaining patient lives and remains disease-free. The mean follow-up period was 33 months. One patient had local recurrence outside the irradiated graft at 20 months after surgery. The functional rating was 22. Lower scores were seen in patients with reconstruction of flexor tendons than extensor tendons. Limb salvage operation with intraoperative extracorporeal autogenous irradiated tendon grafts is an acceptable method in selected patients with soft tissue sarcoma of the wrist and hand.

  10. Correspondence of high-frequency ultrasound and histomorphometry of healing rabbit Achilles tendon tissue.

    Science.gov (United States)

    Buschmann, Johanna; Puippe, Gilbert; Bürgisser, Gabriella Meier; Bonavoglia, Eliana; Giovanoli, Pietro; Calcagni, Maurizio

    2014-04-01

    Static and dynamic high-frequency ultrasound of healing rabbit Achilles tendons were set in relationship to histomorphometric analyses at three and six weeks post-surgery. Twelve New Zealand White rabbits received a clean-cut Achilles tendon laceration (the medial and lateral Musculus gastrocnemius) and were repaired with a four-strand Becker suture. Six rabbits got additionally a tight polyester urethane tube at the repair site in order to vary the adhesion extent. Tendons were analysed by static and dynamic ultrasound (control: healthy contralateral legs). The ultrasound outcome was corresponded to the tendon shape, tenocyte and tenoblast density, tenocyte and tenoblast nuclei width, collagen fibre orientation and adhesion extent. The spindle-like morphology of healing tendons (ultrasound) was confirmed by the swollen epitenon (histology). Prediction of adhesion formation by dynamic ultrasound assessment was confirmed by histology (contact region to surrounding tissue). Hyperechogenic areas corresponded to acellular zones with aligned fibres and hypoechogenic zones to not yet oriented fibres and to cell-rich areas. These findings add new in-depth structural knowledge to the established non-invasive analytical tool, ultrasound.

  11. Influence and evolution mechanism of different sharpness contact forms to mechanical property of cortical bone by nanoindentation

    Science.gov (United States)

    Sun, Xingdong; Guo, Yue; Li, Lijia; Liu, Zeyang; Wu, Di; Shi, Dong; Zhao, Hongwei; Zhang, Shizhong

    2018-03-01

    Based on different damage forms of various contact forms to bone, the mechanical response and mechanism were investigated by nanoindentation under different sharpness contact forms. For the purpose of simulating the different sharpness contact forms, two kinds of indenters were used in experiments and finite elements simulations. Through nanoindentation experiments, it was concluded that the residual depth of sharp indenter was bigger than that of blunt indenter with small penetration depth. However, the contrary law was obtained with bigger penetration depth. There was a turning point of transition from blunt tendency to sharp tendency. By calculation, it was concluded that the sharper the indenter was, the bigger the proportion of plastic energy in total energy was. Basically, results of finite elements simulation could correspond with the experimental conclusions. By the observation of FE-SEM, the surface of cortical bone compressed was more seriously directly below the blunt indenter than the lateral face. For the berkovich indenter, the surface of indentation compressed was less directly below the indenter, but seriously on three lateral faces. This research may provide some new references to the studies of bone fracture mechanism in different load patterns in the initial press-in stage and offer new explanation for bone trauma diagnosis in clinical treatment and criminal investigation.

  12. Influence and evolution mechanism of different sharpness contact forms to mechanical property of cortical bone by nanoindentation

    Directory of Open Access Journals (Sweden)

    Xingdong Sun

    2018-03-01

    Full Text Available Based on different damage forms of various contact forms to bone, the mechanical response and mechanism were investigated by nanoindentation under different sharpness contact forms. For the purpose of simulating the different sharpness contact forms, two kinds of indenters were used in experiments and finite elements simulations. Through nanoindentation experiments, it was concluded that the residual depth of sharp indenter was bigger than that of blunt indenter with small penetration depth. However, the contrary law was obtained with bigger penetration depth. There was a turning point of transition from blunt tendency to sharp tendency. By calculation, it was concluded that the sharper the indenter was, the bigger the proportion of plastic energy in total energy was. Basically, results of finite elements simulation could correspond with the experimental conclusions. By the observation of FE-SEM, the surface of cortical bone compressed was more seriously directly below the blunt indenter than the lateral face. For the berkovich indenter, the surface of indentation compressed was less directly below the indenter, but seriously on three lateral faces. This research may provide some new references to the studies of bone fracture mechanism in different load patterns in the initial press-in stage and offer new explanation for bone trauma diagnosis in clinical treatment and criminal investigation.

  13. Comparison of bone-implant contact and bone-implant volume between 2D-histological sections and 3D-SRµCT slices

    Directory of Open Access Journals (Sweden)

    R Bernhardt

    2012-04-01

    Full Text Available Histological imaging is still considered the gold standard for analysing bone formation around metallic implants. Generally, a limited number of histological sections per sample are used for the approximation of mean values of peri-implant bone formation. In this study we compared statistically the results of bone-implant contact (BIC and bone-implant volume (BIV obtained by histological sections, with those obtained by X-ray absorption images from synchrotron radiation micro-computed tomography (SRµCT using osseointegrated screw-shaped implants from a mini-pig study. Comparing the BIC results of 3-4 histological sections per implant sample with the appropriate 3-4 SRµCT slices showed a non-significant difference of 1.9 % (p = 0.703. The contact area assessed by the whole 3D information from the SRµCT measurement in comparison to the histomorphometric results showed a non-significant difference in BIC of 4.9 % (p = 0.171. The amount of the bone-implant volume in the histological sections and the appropriate SRµCT slices showed a non-significant difference by only 1.4 % (p = 0.736 and also remains non-significant with 2.6 % (p = 0.323 using the volumetric SRµCT information. We conclude that for a clinical evaluation of implant osseointegration with histological imaging at least 3-4 sections per sample are sufficient to represent the BIC or BIV for a sample. Due to the fact that in this study we have found a significant intra-sample variation in BIC of up to ± 35 % the selection of only one or two histological sections per sample may strongly influence the determined BIC.

  14. Specific interface area in a thin layer system of two immiscible liquids with vapour generation at the contact interface

    Science.gov (United States)

    Pimenova, Anastasiya V.; Gazdaliev, Ilias M.; Goldobin, Denis S.

    2017-06-01

    For well-stirred multiphase fluid systems the mean interface area per unit volume, or “specific interface area” SV, is a significant characteristic of the system state. In particular, it is important for the dynamics of systems of immiscible liquids experiencing interfacial boiling. We estimate the value of parameter SV as a function of the heat influx {\\dot{Q}}V to the system or the average system overheat above the interfacial boiling point. The derived results can be reformulated for the case of an endothermic chemical reaction between two liquid reagents with the gaseous form of one of the reaction products. The final results are restricted to the case of thin layers, where the potential gravitational energy of bubbles leaving the contact interface is small compared to their surface tension energy.

  15. MR imaging of the Achilles tendon: overlap of findings in symptomatic and asymptomatic individuals

    International Nuclear Information System (INIS)

    Haims, A.H.; Schweitzer, M.E.; Patel, R.S.

    2000-01-01

    Objective: To differentiate MR imaging characteristics of symptomatic as compared with asymptomatic Achilles tendons.Design: 1.5 T MR images of 94 feet (88 patients) with ''abnormal'' MR examinations were retrospectively evaluated and clinically correlated. Two masked, independent observers systematically evaluated for intratendon T2 signal, tendon thickness, presence of peritendonitis, retrocalcaneal bursal fluid volume, pre-Achilles edema, bone marrow edema at the Achilles insertion, and tears (interstitial, partial, complete). These findings were correlated with symptoms (onset and duration) and physical examination results (tenderness, palpable defects, increased angle of resting dorsiflexion).Results: Of the 94 ankles, 64 ankles (32 females, 29 males) were clinically symptomatic. No relationship between Achilles tendon disorders and age or gender was identified. Asymptomatic Achilles tendons frequently demonstrated mild increased intratendon signal (21/30), 0.747 cm average tendon thickness, peritendonitis (11/30), pre-Achilles edema (12/30), and 0.104 ml average retrocalcaneal bursal fluid volume. Symptomatic patients had thicker tendons (0.877 cm), greater retrocalcaneal fluid volume (0.278 ml), more frequent tears (23/64), a similar frequency of peritendonitis (22/64) but less frequent pre-Achilles edema (18/64). Sixty-four percent of the Achilles tendon tears were interstitial. Except for two interstitial tears in control patients, the majority of Achilles tears were in symptomatic patients (14/16). Only symptomatic tendons demonstrated partial or complete tendon tears. In addition, calcaneal edema was found almost exclusively in actively symptomatic patients. Thicker tendons were associated more often with chronic symptoms and with tears. When present in symptomatic patients, peritendonitis was usually associated with acute symptoms. The presence of pre-Achilles edema, however, did not distinguish acute from chronic disorders.Conclusion: There is

  16. [Scanning electron microscopy observation of the growth of osteoblasts on Ti-24Nb-4Zr-8Sn modified by micro-arc oxidation and alkali-heat treatment and implant-bone interface].

    Science.gov (United States)

    Han, Xue; Liu, Hong-Chen; Wang, Dong-Sheng; Li, Shu-Jun; Yang, Rui

    2011-01-01

    To observe the efficacy of micro-arc oxidation and alkali-heat treatment (MAH) on Ti-24Nb-4Zr-8Sn (Ti2448). Disks (diameter of 14.5 mm, thickness of 1 mm) and cylinders (diameter of 3 mm, height of 10 mm) were fabricated from Ti2448 alloy. Samples were divided into three groups: polished (Ti2448), micro-arc oxidation(MAO-Ti2448), micro-arc oxidation and alkali-heat treatment (MAH-Ti2448). MC3T3-E1 osteoblastic cells were cultured on the disks and cell morphology was observed with scanning electron microscopy (SEM) aftre 3 days. The cylinder samples were implanted in the tibia of dogs and implant-bone interface was observed with SEM after 3 months. A rough and porous structure was shown in both MAO and MAH group. The MC3T3-E1 cells on the MAH-Ti2448 discs spread fully in intimate contact with the underlying coarse surface through active cytoskeletal extentions. Osseointegration was formed in the implant-bone interface in MAH samples. MAH treatment can provide a more advantageous Ti2448 surface to osteoblastic cells than MAO treatment does, and the former can improve the implant-bone integration.

  17. FUNCTIONAL OUTCOME OF ACCELERATED REHABILITATION IN ARTHROSCOPIC ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION WITH BONE PATELLAR TENDON BONE GRAFT A PROSPECTIVE STUDY

    Directory of Open Access Journals (Sweden)

    Hiranyakumar

    2016-03-01

    Full Text Available INTRODUCTION An ideal rehabilitation program post anterior cruciate ligament reconstruction enables an individual to return to pre injury levels at a faster rate with minimal to no risk of reinjury to the graft. Rehabilitation protocols have changed considerably over time in the past. It has become “aggressive”, meaning an intensive rehabilitation which includes greater variety of exercises and sports related training. AIM OF THE STUDY The aim of our study is to assess the outcome of accelerated rehabilitation post anterior cruciate ligament (ACL reconstruction. METHODOLOGY 106 patients were operated by a single surgeon underwent arthroscopic anterior cruciate ligament reconstruction using bone patella tendon bone graft and partial meniscectomy for associated meniscal tear. Patients were put on an accelerated rehabilitation protocol designed in our institute on first post-operative day, under the guidance of a physical therapist in consultation with the operated surgeon. Patients were followed up at 3 weeks, 6 months and 9 months, post onset of rehabilitation, patients were assessed using KT1000 Arthrometer and Lysholm knee scoring system. RESULTS Out of 106 patients, who were selected, 96(91% were males and 10(9% were females. The mean pre-operative Lysholm score was 55.09. Post operatively, while on accelerated rehabilitation program the Lysholm scores were 69.73 at 3 weeks, 89.13 at 6 months and 89.19 at 9 months. In our pre-operative evaluation mean KT 1000 arthrometer score was 10.53 and post-operative at six months was 3.49. At nine months 105 patients had excellent results whereas 1 patient had good result. CONCLUSION Accelerated rehabilitation protocol enables the patient to functionally recover faster to pre injury levels. A rehabilitation protocol for 6 months is sufficient in enabling a patient to get back to pre-injury levels. Functional outcome is the same with or without associated meniscal injuries.

  18. Absorbed dose calculation of the energy deposition close to bone, lung and soft tissue interfaces in molecular radiotherapy

    International Nuclear Information System (INIS)

    Fernandez, M.; Lassman, M.

    2015-01-01

    Full text of publication follows. Aim: for voxel-based dosimetry in molecular radiotherapy (MRT) based on tabulated voxel S-values these values are usually obtained only for soft tissue. In order to study the changes in the dose deposition patterns at interfaces between different materials we have performed Monte Carlo simulations. Methods: the deposited energy patterns were obtained using the Monte-Carlo radiation code MCNPX v2.7 for Lu 177 (medium-energy) and Y 90 (high-energy). The following interfaces were studied: soft tissue-bone and soft tissue-lungs. For this purpose a volume of soft tissue homogeneously filled with Lu 177 or Y 90 was simulated at the interface to 3 different volumes containing no activity: soft tissue, lungs and bone. The emission was considered to be isotropic. The dimensions were chosen to ensure that the energy deposited by all generated particles was scored. The materials were defined as recommended by ICPR46; the decay schemes of Eckerman and Endo were used. With these data the absorbed dose patterns normalized to the maximum absorbed dose in the source region (soft tissue) were calculated. Results: the absorbed dose fractions in the boundary with soft tissue, bone and lungs are 50%, 47% and 57%, respectively, for Lu 177 and 50%, 47% and 51% for Y 90 . The distances to the interface at which the absorbed fractions are at 0.1% are 1.0, 0.6 and 3.0 mm for Lu 177 and 7.0, 4.0 and 24 mm for Y 90 , for soft tissue, bone and lungs respectively. Conclusions: in MRT, the changes in the absorbed doses at interfaces between soft tissue and bone/lungs need to be considered for isotopes emitting high energy particles. (authors)

  19. A Modified Suture Bridge Technique for Application With Bone Anchors in Foot and Ankle Surgery.

    Science.gov (United States)

    Walters, Jeremy; Correa, Christopher; Moss, Mark

    2015-01-01

    We present a suture bridge technique for reattachment of tendon or ligament to bone for use in foot and ankle surgery. The method is a simple, strong, and reproducible technique that could decrease the risk of irritation of the overlying cutaneous barrier and minimizes the likelihood of tendon strangulation when combined with soft tissue bone anchors. The present report serves as a guide to the use of this suture technique for reattachment of the Achilles tendon. Copyright © 2015 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  20. Ultrasonographic findings of Achilles tendon and plantar fascia in patients with calcium pyrophosphate deposition disease.

    Science.gov (United States)

    Ellabban, Abdou S; Kamel, Shereen R; Abo Omar, Hanaa A S; El-Sherif, Ashraf M H; Abdel-Magied, Rasha A

    2012-04-01

    The aims of the study were to detect the frequency of involvement of the Achilles tendon and plantar fascia in patients with calcium pyrophosphate deposition disease (CPPD) by high-frequency gray-scale ultrasonography (US) and power Doppler sonography (PDS) and to correlate these findings with demographic and clinical data. Two groups of patients were enrolled: group I (38 patients with CPPD) and group II (22 patients with knee OA). US/PDS examination of the heels was performed to both groups. In the CPPD group, US/PDS examination of the Achilles tendon revealed: calcification in 57.9%, enthesophytosis in 57.9%, enthesopathy in 23.7%, vascular sign in 21%, bursitis in 13.2%, and cortical bone irregularity in 10.5%. US/PDS examination of plantar fascia in the CPPD group revealed: calcification in 15.8%, cortical bone irregularity in 78.9%, enthesophytosis in 60.5%, and planter fasciitis in 42.1%. In patients with CPPD, age was significantly correlated with enthesophytosis and deep retrocalcaneal bursitis (p = 0.01 and p = 0.04, respectively). Heel tenderness and posterior talalgia were significantly correlated with Achilles tendon enthesopathy, vascular sign, and deep retrocalcaneal bursitis (p = 0.0001 for each). Inferior talalgia was significantly correlated with plantar fasciitis (p = 0.0001). The sensitivity of ultrasonography for detection of calcifications in Achilles tendon and plantar fascia was 57.9% and 15.8%, respectively, and the specificity was 100% for both. To conclude, ultrasonographic Achilles tendon and plantar fascia calcifications are frequent findings in patients with CPPD. These calcifications have a high specificity and can be used as a useful indirect sign of CPPD.

  1. Influences of microgap and micromotion of implant-abutment interface on marginal bone loss around implant neck.

    Science.gov (United States)

    Liu, Yang; Wang, Jiawei

    2017-11-01

    To review the influences and clinical implications of micro-gap and micro-motion of implant-abutment interface on marginal bone loss around the neck of implant. Literatures were searched based on the following Keywords: implant-abutment interface/implant-abutment connection/implant-abutment conjunction, microgap, micromotion/micromovement, microleakage, and current control methods available. The papers were then screened through titles, abstracts, and full texts. A total of 83 studies were included in the literature review. Two-piece implant systems are widely used in clinics. However, the production error and masticatory load result in the presence of microgap and micromotion between the implant and the abutment, which directly or indirectly causes microleakage and mechanical damage. Consequently, the degrees of microgap and micromotion further increase, and marginal bone absorption finally occurs. We summarize the influences of microgap and micromotion at the implant-abutment interface on marginal bone loss around the neck of the implant. We also recommend some feasible methods to reduce their effect. Clinicians and patients should pay more attention to the mechanisms as well as the control methods of microgap and micromotion. To reduce the corresponding detriment to the implant marginal bone, suitable Morse taper or hybrid connection implants and platform switching abutments should be selected, as well as other potential methods. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Quadriceps Tendon Autograft in Anterior Cruciate Ligament Reconstruction: A Systematic Review.

    Science.gov (United States)

    Hurley, Eoghan T; Calvo-Gurry, Manuel; Withers, Dan; Farrington, Shane K; Moran, Ray; Moran, Cathal J

    2018-05-01

    To systematically review the current evidence to ascertain whether quadriceps tendon autograft (QT) is a viable option in anterior cruciate ligament reconstruction. A literature review was conducted in accordance with Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) guidelines. Cohort studies comparing QT with bone-patellar tendon-bone autograft (BPTB) or hamstring tendon autograft (HT) were included. Clinical outcomes were compared, with all statistical analyses performed using IBM SPSS Statistics for Windows, version 22.0, with P < .05 being considered statistically significant. We identified 15 clinical trials with 1,910 patients. In all included studies, QT resulted in lower rates of anterior knee pain than BPTB. There was no difference in the rate of graft rupture between QT and BPTB or HT in any of the studies reporting this. One study found that QT resulted in greater knee stability than BPTB, and another study found increased stability compared with HT. One study found that QT resulted in improved functional outcomes compared with BPTB, and another found improved outcomes compared with HT, but one study found worse outcomes compared with BPTB. Current literature suggests QT is a viable option in anterior cruciate ligament reconstruction, with published literature showing comparable knee stability, functional outcomes, donor-site morbidity, and rerupture rates compared with BPTB and HT. Level III, systematic review of Level I, II, and III studies. Copyright © 2018 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  3. Osmotic pressure induced tensile forces in tendon collagen.

    Science.gov (United States)

    Masic, Admir; Bertinetti, Luca; Schuetz, Roman; Chang, Shu-Wei; Metzger, Till Hartmut; Buehler, Markus J; Fratzl, Peter

    2015-01-22

    Water is an important component of collagen in tendons, but its role for the function of this load-carrying protein structure is poorly understood. Here we use a combination of multi-scale experimentation and computation to show that water is an integral part of the collagen molecule, which changes conformation upon water removal. The consequence is a shortening of the molecule that translates into tensile stresses in the range of several to almost 100 MPa, largely surpassing those of about 0.3 MPa generated by contractile muscles. Although a complete drying of collagen would be relevant for technical applications, such as the fabrication of leather or parchment, stresses comparable to muscle contraction already occur at small osmotic pressures common in biological environments. We suggest, therefore, that water-generated tensile stresses may play a role in living collagen-based materials such as tendon or bone.

  4. Ipsilateral free semitendinosus tendon graft transfer for reconstruction of chronic tears of the Achilles tendon

    Directory of Open Access Journals (Sweden)

    Gougoulias Nikolaos

    2008-07-01

    Full Text Available Abstract Background Many techniques have been developed for the reconstruction of the Achilles tendon in chronic tears. In presence of a large gap (greater than 6 centimetres, tendon augmentation is required. Methods We present our method of minimally invasive semitendinosus reconstruction for the Achilles tendon using one para-midline and one midline incision. Results The first incision is a 5 cm longitudinal incision, made 2 cm proximal and just medial to the palpable end of the residual tendon. The second incision is 3 cm long and is also longitudinal but is 2 cm distal and in the midline to the distal end of the tendon rupture. The distal and proximal Achilles tendon stumps are mobilised. After trying to reduce the gap of the ruptured Achilles tendon, if the gap produced is greater than 6 cm despite maximal plantar flexion of the ankle and traction on the Achilles tendon stumps, the ipsilateral semitendinosus tendon is harvested. The semitendinosus tendon is passed through small incisions in the substance of the proximal stump of the Achilles tendon, and it is sutured to the Achilles tendon. It is then passed beneath the intact skin bridge into the distal incision, and passed from medial to lateral through a transverse tenotomy in the distal stump. With the ankle in maximal plantar flexion, the semitendinosus tendon is sutured to the Achilles tendon at each entry and exit point Conclusion This minimally invasive technique allows reconstruction of the Achilles tendon using the tendon of semitendinosus preserving skin integrity over the site most prone to wound breakdown, and can be especially used to reconstruct the Achilles tendon in the presence of large gap (greater than 6 centimetres.

  5. Adipose derived stromal vascular fraction improves early tendon healing: an experimental study in rabbits

    Directory of Open Access Journals (Sweden)

    Mehdi Behfar

    2011-11-01

    Full Text Available Tendon never restores the complete biological and mechanical properties after healing. Bone marrow and recently adipose tissue have been used as the sources of mesenchymal stem cells, which have been proven to enhance tendon healing. Stromal vascular fraction (SVF, derived from adipose tissue by an enzymatic digestion, represents an alternative source of multipotent cells, which undergo differentiation into multiple lineages to be used in regenerative medicine. In the present study, we investigated potentials of this source on tendon healing. Twenty rabbits were divided into control and treatment groups. Five rabbits were used as donors of adipose tissue. The injury model was unilateral complete transection through the middle one third of deep digital flexor tendon. Immediately after suture repair, either fresh stromal vascular fraction from enzymatic digestion of adipose tissue or placebo was intratendinously injected into the suture site in treatments and controls, respectively. Cast immobilization was continued for two weeks after surgery. Animals were sacrificed at the third week and tendons underwent histological, immunohistochemical, and mechanical evaluations. By histology, improved fibrillar organization and remodeling of neotendon were observed in treatment group. Immunohistochemistry revealed an insignificant increase in collagen type III and I expression in treatments over controls. Mechanical testing showed significant increase in maximum load and energy absorption in SVF treated tendons. The present study showed that intratendinous injection of uncultured adipose derived stromal vascular fraction improved structural and mechanical properties of repaired tendon and it could be an effective modality for treating tendon laceration.

  6. Degeneration of the long biceps tendon: comparison of MRI with gross anatomy and histology.

    Science.gov (United States)

    Buck, Florian M; Grehn, Holger; Hilbe, Monika; Pfirrmann, Christian W A; Manzanell, Silvana; Hodler, Jürg

    2009-11-01

    The objective of our study was to relate alterations in biceps tendon diameter and signal on MR images to gross anatomy and histology. T1-weighted, T2-weighted fat-saturated, and proton density-weighted fat-saturated spin-echo sequences were acquired in 15 cadaveric shoulders. Biceps tendon diameter (normal, flattened, thickened, and partially or completely torn) and signal intensity (compared with bone, fat, muscle, and joint fluid) were graded by two readers independently and in a blinded fashion. The distance of tendon abnormalities from the attachment at the glenoid were noted in millimeters. MRI findings were related to gross anatomic and histologic findings. On the basis of gross anatomy, there were six normal, five flattened, two thickened, and two partially torn tendons. Reader 1 graded nine diameter changes correctly, missed two, and incorrectly graded four. The corresponding values for reader 2 were seven, one, and five, respectively, with kappa = 0.75. Histology showed mucoid degeneration (n = 13), lipoid degeneration (n = 7), and fatty infiltration (n = 6). At least one type of abnormality was found in each single tendon. Mucoid degeneration was hyperintense compared with fatty infiltration on T2-weighted fat-saturated images and hyperintense compared with magic-angle artifacts on proton density-weighted fat-saturated images. MRI-based localization of degeneration agreed well with histologic findings. Diameter changes are specific but not sensitive in diagnosing tendinopathy of the biceps tendon. Increased tendon signal is most typical for mucoid degeneration but should be used with care as a sign of tendon degeneration.

  7. Improvement of the electrical contact resistance at rough interfaces using two dimensional materials

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Jianchen; Pan, Chengbin; Lanza, Mario, E-mail: mlanza@suda.edu.cn [Institute of Functional Nano & Soft Materials (FUNSOM), Collaborative Innovation Center of Suzhou Nanoscience and Technology, Soochow University, 199 Ren-Ai Road, Suzhou 215123 (China); Li, Heng [State Key Laboratory for Turbulence and Complex System, Department of Mechanics and Engineering Science, College of Engineering, Peking University, Beijing 100871 (China); CAPT, HEDPS and IFSA Collaborative Innovation Center of MoE, Peking University, Beijing 100871 (China); Shen, Panpan; Sun, Hui; Duan, Huiling [State Key Laboratory for Turbulence and Complex System, Department of Mechanics and Engineering Science, CAPT, College of Engineering, Peking University, Beijing 100871 (China)

    2015-12-07

    Reducing the electronic contact resistance at the interfaces of nanostructured materials is a major goal for many kinds of planar and three dimensional devices. In this work, we develop a method to enhance the electronic transport at rough interfaces by inserting a two dimensional flexible and conductive graphene sheet. We observe that an ultra-thin graphene layer with a thickness of 0.35 nm can remarkably reduce the roughness of a sample in a factor of 40%, avoiding the use of thick coatings, leading to a more homogeneous current flow, and extraordinarily increasing the total current compared to the graphene-free counterpart. Due to its simplicity and performance enhancement, this methodology can be of interest to many interface and device designers.

  8. Quantification of Internal Stress-Strain Fields in Human Tendon: Unraveling the Mechanisms that Underlie Regional Tendon Adaptations and Mal-Adaptations to Mechanical Loading and the Effectiveness of Therapeutic Eccentric Exercise

    Science.gov (United States)

    Maganaris, Constantinos N.; Chatzistergos, Panagiotis; Reeves, Neil D.; Narici, Marco V.

    2017-01-01

    By virtue of their anatomical location between muscles and bones, tendons make it possible to transform contractile force to joint rotation and locomotion. However, tendons do not behave as rigid links, but exhibit viscoelastic tensile properties, thereby affecting the length and contractile force in the in-series muscle, but also storing and releasing elastic stain energy as some tendons are stretched and recoiled in a cyclic manner during locomotion. In the late 90s, advancements were made in the application of ultrasound scanning that allowed quantifying the tensile deformability and mechanical properties of human tendons in vivo. Since then, the main principles of the ultrasound-based method have been applied by numerous research groups throughout the world and showed that tendons increase their tensile stiffness in response to exercise training and chronic mechanical loading, in general, by increasing their size and improving their intrinsic material. It is often assumed that these changes occur homogenously, in the entire body of the tendon, but recent findings indicate that the adaptations may in fact take place in some but not all tendon regions. The present review focuses on these regional adaptability features and highlights two paradigms where they are particularly evident: (a) Chronic mechanical loading in healthy tendons, and (b) tendinopathy. In the former loading paradigm, local tendon adaptations indicate that certain regions may “see,” and therefore adapt to, increased levels of stress. In the latter paradigm, local pathological features indicate that certain tendon regions may be “stress-shielded” and degenerate over time. Eccentric exercise protocols have successfully been used in the management of tendinopathy, without much sound understanding of the mechanisms underpinning their effectiveness. For insertional tendinopathy, in particular, it is possible that the effectiveness of a loading/rehabilitation protocol depends on the topography

  9. Synchrotron radiation μCT and histology evaluation of bone-to-implant contact

    DEFF Research Database (Denmark)

    Neldam, Camilla Albeck; Sporring, Jon; Rack, Alexander

    2017-01-01

    The purpose of this study was to evaluate bone-to-implant contact (BIC) in two-dimensional (2D) histology compared to high-resolution three-dimensional (3D) synchrotron radiation micro computed tomography (SR micro-CT). High spatial resolution, excellent signal-to-noise ratio, and contrast...... establish SR micro-CT as the leading imaging modality for hard X-ray microtomography. Using SR micro-CT at voxel size 5 μm in an experimental goat mandible model, no statistically significant difference was found between the different treatment modalities nor between recipient and reconstructed bone....... Comparing histology and SR micro-CT evaluation a bias of 5.2% was found in reconstructed area, and 15.3% in recipient bone. We conclude that for evaluation of BIC with histology and SR micro-CT, SR micro-CT cannot be proven more precise than histology for evaluation of BIC, however, with this SR micro-CT...

  10. Elemental and structural studies at the bone-cartilage interface

    International Nuclear Information System (INIS)

    Kaabar, W.; Daar, E.; Bunk, O.; Farquharson, M.J.; Laklouk, A.; Bailey, M.; Jeynes, C.; Gundogdu, O.; Bradley, D.A.

    2011-01-01

    Micro-Proton Induced X-ray Emission (μ-PIXE) and Proton Induced Gamma-ray Emission (PIGE) techniques were employed in the investigation of trace and essential elements distribution in normal and diseased human femoral head sections affected by osteoarthritis (OA). PIGE was exploited in the determination of elements of low atomic number z 15 viz Ca, Z, P and S were determined by PIXE. Accumulations of key elements in the bone and cartilage sections were observed, significant S and Na concentrations being found in the cartilage region particularly in normal tissues. Zn showed enhanced concentrations at the bone-cartilage interface. At a synchrotron facility, small angle X-ray scattering (SAXS) was utilized on a decalcified human femoral head section affected by OA, direct measurements being made of spatial alterations of collagen fibres. The SAXS results showed a slight decrease in the axial periodicity between normal collagen type I and that in diseased tissue in various sites, in contrast with the findings of others.

  11. Composite coating of 58S bioglass and hydroxyapatite on a poly (ethylene terepthalate) artificial ligament graft for the graft osseointegration in a bone tunnel

    Energy Technology Data Exchange (ETDEWEB)

    Li Hong; Wu Yang; Ge Yunsheng; Jiang Jia; Gao Kai [Department of Sports Medicine, Huashan Hospital, Shanghai (China); Zhang Pengyun; Wu Lingxiang [Shanghai Research Center of Biomedical Engineering, Shanghai (China); Chen Shiyi, E-mail: cshiyi@163.com [Department of Sports Medicine, Huashan Hospital, Shanghai (China)

    2011-09-01

    The purpose of this study was to determine the effect of the combination of hydroxyapatite (HA) and bioglass (BG) on polyethylene terephthalate (PET) artificial ligament graft osseointegration within the bone tunnel. The results of in vitro culturing of MC3T3-E1 mouse osteoblastic cells proved that this HA/BG composite coating can promote the cell compatibility of grafts. A rabbit extraarticular tendon-to-bone healing model was used to evaluate the effect of this composite coating on PET artificial ligaments in vivo. The final results demonstrated that HA/BG coating improved new bone formation at the graft-bone interface and increased the load-to-failure property of graft in bone tunnel compared to the control group at early time. The study has shown that HA/BG composite coating on the PET artificial ligament surface has a positive effect in the induction of artificial ligament osseointegration within the bone tunnel.

  12. Composite coating of 58S bioglass and hydroxyapatite on a poly (ethylene terepthalate) artificial ligament graft for the graft osseointegration in a bone tunnel

    International Nuclear Information System (INIS)

    Li Hong; Wu Yang; Ge Yunsheng; Jiang Jia; Gao Kai; Zhang Pengyun; Wu Lingxiang; Chen Shiyi

    2011-01-01

    The purpose of this study was to determine the effect of the combination of hydroxyapatite (HA) and bioglass (BG) on polyethylene terephthalate (PET) artificial ligament graft osseointegration within the bone tunnel. The results of in vitro culturing of MC3T3-E1 mouse osteoblastic cells proved that this HA/BG composite coating can promote the cell compatibility of grafts. A rabbit extraarticular tendon-to-bone healing model was used to evaluate the effect of this composite coating on PET artificial ligaments in vivo. The final results demonstrated that HA/BG coating improved new bone formation at the graft-bone interface and increased the load-to-failure property of graft in bone tunnel compared to the control group at early time. The study has shown that HA/BG composite coating on the PET artificial ligament surface has a positive effect in the induction of artificial ligament osseointegration within the bone tunnel.

  13. Retrospective study of sonographic findings in bone involvement associated with rotator cuff calcific tendinopathy: preliminary results of a case series

    Directory of Open Access Journals (Sweden)

    Marcello H. Nogueira-Barbosa

    2015-12-01

    Full Text Available Abstract Objective: The present study was aimed at investigating bone involvement secondary to rotator cuff calcific tendonitis at ultrasonography. Materials and Methods: Retrospective study of a case series. The authors reviewed shoulder ultrasonography reports of 141 patients diagnosed with rotator cuff calcific tendonitis, collected from the computer-based data records of their institution over a four-year period. Imaging findings were retrospectively and consensually analyzed by two experienced musculoskeletal radiologists looking for bone involvement associated with calcific tendonitis. Only the cases confirmed by computed tomography were considered for descriptive analysis. Results: Sonographic findings of calcific tendinopathy with bone involvement were observed in 7/141 (~ 5% patients (mean age, 50.9 years; age range, 42-58 years; 42% female. Cortical bone erosion adjacent to tendon calcification was the most common finding, observed in 7/7 cases. Signs of intraosseous migration were found in 3/7 cases, and subcortical cysts in 2/7 cases. The findings were confirmed by computed tomography. Calcifications associated with bone abnormalities showed no acoustic shadowing at ultrasonography, favoring the hypothesis of resorption phase of the disease. Conclusion: Preliminary results of the present study suggest that ultrasonography can identify bone abnormalities secondary to rotator cuff calcific tendinopathy, particularly the presence of cortical bone erosion.

  14. Comparative Study on Interface Elements, Thin-Layer Elements, and Contact Analysis Methods in the Analysis of High Concrete-Faced Rockfill Dams

    Directory of Open Access Journals (Sweden)

    Xiao-xiang Qian

    2013-01-01

    Full Text Available This paper presents a study on the numerical performance of three contact simulation methods, namely, the interface element, thin-layer element, and contact analysis methods, through the analysis of the contact behavior between the concrete face slab and the dam body of a high concrete-faced rockfill dam named Tianshengqiao-I in China. To investigate the accuracy and limitations of each method, the simulation results are compared in terms of the dam deformation, contact stress along the interface, stresses in the concrete face slab, and separation of the concrete face slab from the cushion layer. In particular, the predicted dam deformation and slab separation are compared with the in-situ observation data to classify these methods according to their agreement with the in-situ observations. It is revealed that the interface element and thin-layer element methods have their limitations in predicting contact stress, slab separation, and stresses in the concrete face slab if a large slip occurs. The contact analysis method seems to be the best choice whether the separation is finite or not.

  15. Gastrocnemius tendon strain in a dog treated with autologous mesenchymal stem cells and a custom orthosis.

    Science.gov (United States)

    Case, J Brad; Palmer, Ross; Valdes-Martinez, Alex; Egger, Erick L; Haussler, Kevin K

    2013-05-01

    To report clinical findings and outcome in a dog with gastrocnemius tendon strain treated with autologous mesenchymal stem cells and a custom orthosis. Clinical report. A 4-year-old spayed female Border Collie. Bone-marrow derived, autologous mesenchymal stem cells were transplanted into the tendon core lesion. A custom, progressive, dynamic orthosis was fit to the tarsus. Serial orthopedic examinations and ultrasonography as well as long-term force-plate gait analysis were utilized for follow up. Lameness subjectively resolved and peak vertical force increased from 43% to 92% of the contralateral pelvic limb. Serial ultrasonographic examinations revealed improved but incomplete restoration of normal linear fiber pattern of the gastrocnemius tendon. Findings suggest that autologous mesenchymal stem cell transplantation with custom, progressive, dynamic orthosis may be a viable, minimally invasive technique for treatment of calcaneal tendon injuries in dogs. © Copyright 2013 by The American College of Veterinary Surgeons.

  16. Achilles Tendonitis

    Science.gov (United States)

    ... almost impossible. Achilles tendonitis is a very common running injury. But it can also affect basketball players, dancers, ... Proximal Biceps Tendonitis Safety Tips: Basketball Safety Tips: Running Repetitive Stress Injuries Sports and Exercise Safety Dealing With Sports Injuries ...

  17. The effect of layer-by-layer chitosan-hyaluronic acid coating on graft-to-bone healing of a poly(ethylene terephthalate) artificial ligament.

    Science.gov (United States)

    Li, Hong; Ge, Yunsheng; Zhang, Pengyun; Wu, Lingxiang; Chen, Shiyi

    2012-01-01

    Surface coating with an organic layer-by-layer self-assembled template of chitosan and hyaluronic acid on a poly(ethylene terephthalate) (PET) artificial ligament was designed for the promotion and enhancement of graft-to-bone healing after artificial ligament implantation in a bone tunnel. The results of in vitro culturing of MC3T3-E1 mouse osteoblastic cells supported the hypothesis that the layer-by-layer coating of chitosan and hyaluronic acid could promote the cell compatibility of grafts and could promote osteoblast proliferation. A rabbit extra-articular tendon-to-bone healing model was used to evaluate the effect of this kind of surface-modified stainless artificial ligament in vivo. The final results proved that this organic compound coating could significantly promote and enhance new bone formation at the graft-bone interface histologically and, correspondingly, the experimental group with coating had significantly higher biomechanical properties compared with controls at 8 weeks (P < 0.05).

  18. Synchrotron radiation μCT and histology evaluation of bone-to-implant contact.

    Science.gov (United States)

    Neldam, Camilla Albeck; Sporring, Jon; Rack, Alexander; Lauridsen, Torsten; Hauge, Ellen-Margrethe; Jørgensen, Henrik L; Jørgensen, Niklas Rye; Feidenhansl, Robert; Pinholt, Else Marie

    2017-09-01

    The purpose of this study was to evaluate bone-to-implant contact (BIC) in two-dimensional (2D) histology compared to high-resolution three-dimensional (3D) synchrotron radiation micro computed tomography (SR micro-CT). High spatial resolution, excellent signal-to-noise ratio, and contrast establish SR micro-CT as the leading imaging modality for hard X-ray microtomography. Using SR micro-CT at voxel size 5 μm in an experimental goat mandible model, no statistically significant difference was found between the different treatment modalities nor between recipient and reconstructed bone. The histological evaluation showed a statistically significant difference between BIC in reconstructed and recipient bone (p micro-CT evaluation a bias of 5.2% was found in reconstructed area, and 15.3% in recipient bone. We conclude that for evaluation of BIC with histology and SR micro-CT, SR micro-CT cannot be proven more precise than histology for evaluation of BIC, however, with this SR micro-CT method, one histologic bone section is comparable to the 3D evaluation. Further, the two methods complement each other with knowledge on BIC in 2D and 3D. Copyright © 2017 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  19. Mechanical Properties of Human Patellar Tendon at the Hierarchical levels of Tendon and Fibril

    DEFF Research Database (Denmark)

    Svensson, Rene Brüggebusch; Hansen, Philip; Hassenkam, Tue

    2012-01-01

    Tendons are strong hierarchical structures, but how tensile forces are transmitted between different levels remains incompletely understood. Collagen fibrils are thought to be primary determinants of whole tendon properties, and therefore we hypothesized that the whole human patellar tendon and its...... distinct collagen fibrils would display similar mechanical properties. Human patellar tendons (n=5) were mechanically tested in vivo by ultrasonography. Biopsies were obtained from each tendon and individual collagen fibrils were dissected and tested mechanically by atomic force microscopy. The Young...... that of tendon supports that fibrillar rather than interfibrillar properties govern sub-failure tendon response, making the fibrillar level a meaningful target of intervention. The lower modulus found in vitro suggests a possible adverse effect of removing the tissue from its natural environment. In addition...

  20. Patellar Sleeve Fracture With Ossification of the Patellar Tendon.

    Science.gov (United States)

    Damrow, Derek S; Van Valin, Scott E

    2017-03-01

    Patellar sleeve fractures make up greater than 50% of all patellar fractures. They are essentially only seen in the pediatric population because of the thick periosteum and the distal patellar pole apophysis in this group. These fractures can lead to complications if not treated appropriately and in a timely fashion. Complications of missed or untreated patellar sleeve fractures include patella alta, anterior knee pain, and quadriceps atrophy. These can all result in severe limitations in activity. The authors describe a case of a 16-year-old boy who sustained a patellar sleeve fracture 3 years prior to presentation. On presentation, he had patella alta, diminished strength, 5° of extensor lag, and radiographs that revealed bone formation along the patellar tendon. Despite this, he was able to maintain a high level of activity. This case report explores how the patient could have maintained a high level of activity despite having a patellar sleeve fracture. Also, because of the delayed presentation, the patella was ossified and the quadriceps was retracted, which led to a novel approach to reconstructing his distal extensor mechanism. This approach included a V-Y advancement of the quadriceps tendon and patellar tendon reconstruction using the patient's hamstring tendon (semitendinosus). This technique, combined with physical therapy postoperatively, resulted in his return to varsity high school soccer. To the best of the authors' knowledge, this technique has not been reported for this rare condition. [Orthopedics. 2017; 40(2):e357-e359.]. Copyright 2016, SLACK Incorporated.

  1. Fibroma of the tendon sheath of the long head of the biceps tendon

    International Nuclear Information System (INIS)

    Maeseneer, Michel de; Shahabpour, Maryam; Isacker, Tom van; Lenchik, Leon; Caillie, Marie-Astrid van

    2014-01-01

    Fibroma of the tendon sheath is a benign tumor that is less common than giant cell tumor of the tendon sheath. Both tumors may present as a painless, slowly enlarging mass. Radiological findings may be similar for both tumors. Histologically, fibroma of the tendon sheath lacks the hemosiderin-laden macrophages that are typical for giant cell tumor of the tendon sheath. We report on a 49-year-old woman with fibroma of the tendon sheath of the long head of the biceps tendon. In our case, on MR images, we observed band-like hypointense areas centrally in the tumor, mild patchy contrast enhancement, and most importantly, no decrease of signal intensity on gradient echo images. These characteristics reflected histological findings. (orig.)

  2. The mechanism for efficacy of eccentric loading in Achilles tendon injury; an in vivo study in humans.

    Science.gov (United States)

    Rees, J D; Lichtwark, G A; Wolman, R L; Wilson, A M

    2008-10-01

    Degenerative disorders of tendons present an enormous clinical challenge. They are extremely common, prone to recur and existing medical and surgical treatments are generally unsatisfactory. Recently eccentric, but not concentric, exercises have been shown to be highly effective in managing tendinopathy of the Achilles (and other) tendons. The mechanism for the efficacy of these exercises is unknown although it has been speculated that forces generated during eccentric loading are of a greater magnitude. Our objective was to determine the mechanism for the beneficial effect of eccentric exercise in Achilles tendinopathy. Seven healthy volunteers performed eccentric and concentric loading exercises for the Achilles tendon. Tendon force and length changes were determined using a combination of motion analysis, force plate data and real-time ultrasound. There was no significant difference in peak tendon force or tendon length change when comparing eccentric with concentric exercises. However, high-frequency oscillations in tendon force occurred in all subjects during eccentric exercises but were rare in concentric exercises (P < 0.0001). These oscillations provide a mechanism to explain the therapeutic benefit of eccentric loading in Achilles tendinopathy and parallels recent evidence from bone remodelling, where the frequency of the loading cycles is of more significance than the absolute magnitude of the force.

  3. Compression and contact area of anterior strut grafts in spinal instrumentation: a biomechanical study.

    Science.gov (United States)

    Pizanis, Antonius; Holstein, Jörg H; Vossen, Felix; Burkhardt, Markus; Pohlemann, Tim

    2013-08-26

    Anterior bone grafts are used as struts to reconstruct the anterior column of the spine in kyphosis or following injury. An incomplete fusion can lead to later correction losses and compromise further healing. Despite the different stabilizing techniques that have evolved, from posterior or anterior fixating implants to combined anterior/posterior instrumentation, graft pseudarthrosis rates remain an important concern. Furthermore, the need for additional anterior implant fixation is still controversial. In this bench-top study, we focused on the graft-bone interface under various conditions, using two simulated spinal injury models and common surgical fixation techniques to investigate the effect of implant-mediated compression and contact on the anterior graft. Calf spines were stabilised with posterior internal fixators. The wooden blocks as substitutes for strut grafts were impacted using a "pressfit" technique and pressure-sensitive films placed at the interface between the vertebral bone and the graft to record the compression force and the contact area with various stabilization techniques. Compression was achieved either with posterior internal fixator alone or with an additional anterior implant. The importance of concomitant ligament damage was also considered using two simulated injury models: pure compression Magerl/AO fracture type A or rotation/translation fracture type C models. In type A injury models, 1 mm-oversized grafts for impaction grafting provided good compression and fair contact areas that were both markedly increased by the use of additional compressing anterior rods or by shortening the posterior fixator construct. Anterior instrumentation by itself had similar effects. For type C injuries, dramatic differences were observed between the techniques, as there was a net decrease in compression and an inadequate contact on the graft occurred in this model. Under these circumstances, both compression and the contact area on graft could only

  4. Dose equivalent near the bone-soft tissue interface from nuclear fragments produced by high-energy protons

    Science.gov (United States)

    Shavers, M. R.; Poston, J. W.; Cucinotta, F. A.; Wilson, J. W.

    1996-01-01

    During manned space missions, high-energy nucleons of cosmic and solar origin collide with atomic nuclei of the human body and produce a broad linear energy transfer spectrum of secondary particles, called target fragments. These nuclear fragments are often more biologically harmful than the direct ionization of the incident nucleon. That these secondary particles increase tissue absorbed dose in regions adjacent to the bone-soft tissue interface was demonstrated in a previous publication. To assess radiological risks to tissue near the bone-soft tissue interface, a computer transport model for nuclear fragments produced by high energy nucleons was used in this study to calculate integral linear energy transfer spectra and dose equivalents resulting from nuclear collisions of 1-GeV protons transversing bone and red bone marrow. In terms of dose equivalent averaged over trabecular bone marrow, target fragments emitted from interactions in both tissues are predicted to be at least as important as the direct ionization of the primary protons-twice as important, if recently recommended radiation weighting factors and "worst-case" geometry are used. The use of conventional dosimetry (absorbed dose weighted by aa linear energy transfer-dependent quality factor) as an appropriate framework for predicting risk from low fluences of high-linear energy transfer target fragments is discussed.

  5. Achilles tendon and sports

    International Nuclear Information System (INIS)

    Ulreich, N.; Kainberger, F.; Huber, W.; Nehrer, S.

    2002-01-01

    Because of the rising popularity of recreational sports activities achillodynia is an often associated symptom with running, soccer and athletics. Therefore radiologist are frequently asked to image this tendon. The origin of the damage of the Achilles tendon is explained by numerous hypothesis, mainly a decreased perfusion and a mechanical irritation that lead to degeneration of the tendon. High-resolution technics such as sonography and magnetic resonance imaging show alterations in the structure of the tendon which can be graduated and classified. Manifestations like tendinosis, achillobursitis, rupture and Haglunds disease can summarized as the tendon overuse syndrom. A rupture of a tendon is mostly the result of a degeneration of the collagenfibres. The task of the radiologist is to acquire the intrinsic factors for a potential rupture. (orig.) [de

  6. Interface Characterization of Cobalt Contacts on Bismuth Selenium Telluride for Thermoelectric Devices

    KAUST Repository

    Gupta, R. P.; Iyore, O. D.; Xiong, K.; White, J. B.; Cho, Kyeongjae; Alshareef, Husam N.; Gnade, B. E.

    2009-01-01

    Sputtered Co is investigated as a suitable contact metal for bulk Bi2 (Te,Se) 3, and the results are compared to sputtered Ni. The coefficient of thermal expansion of Co matches that of bulk Bi 2 (Te,Se) 3 used in our study, and the compatible interface favors the selection of Co as a contact metal. Significant Ni diffusion into Bi2 (Te,Se) 3 was observed. In contrast, Co on Bi2 (Te,Se) 3 shows significantly less diffusion, even at anneal temperatures as high as 200°C. CoTe2 is the preferred phase that is formed. First principles calculations for Bi2 Te 3 support the experimental observation. © 2009 The Electrochemical Society.

  7. Interface Characterization of Cobalt Contacts on Bismuth Selenium Telluride for Thermoelectric Devices

    KAUST Repository

    Gupta, R. P.

    2009-08-13

    Sputtered Co is investigated as a suitable contact metal for bulk Bi2 (Te,Se) 3, and the results are compared to sputtered Ni. The coefficient of thermal expansion of Co matches that of bulk Bi 2 (Te,Se) 3 used in our study, and the compatible interface favors the selection of Co as a contact metal. Significant Ni diffusion into Bi2 (Te,Se) 3 was observed. In contrast, Co on Bi2 (Te,Se) 3 shows significantly less diffusion, even at anneal temperatures as high as 200°C. CoTe2 is the preferred phase that is formed. First principles calculations for Bi2 Te 3 support the experimental observation. © 2009 The Electrochemical Society.

  8. MDcons: Intermolecular contact maps as a tool to analyze the interface of protein complexes from molecular dynamics trajectories

    KAUST Repository

    Abdel-Azeim, Safwat; Chermak, Edrisse; Vangone, Anna; Oliva, Romina; Cavallo, Luigi

    2014-01-01

    of the similarity between different snapshots. A "consensus contact map" is also provided, where the conservation of the different contacts is drawn in a grey scale. Finally, the interface area of the complex is monitored during the simulations. To show its utility

  9. MDcons: Intermolecular contact maps as a tool to analyze the interface of protein complexes from molecular dynamics trajectories

    KAUST Repository

    Abdel-Azeim, Safwat

    2014-05-06

    Background: Molecular Dynamics ( MD) simulations of protein complexes suffer from the lack of specific tools in the analysis step. Analyses of MD trajectories of protein complexes indeed generally rely on classical measures, such as the RMSD, RMSF and gyration radius, conceived and developed for single macromolecules. As a matter of fact, instead, researchers engaged in simulating the dynamics of a protein complex are mainly interested in characterizing the conservation/variation of its biological interface. Results: On these bases, herein we propose a novel approach to the analysis of MD trajectories or other conformational ensembles of protein complexes, MDcons, which uses the conservation of inter-residue contacts at the interface as a measure of the similarity between different snapshots. A "consensus contact map" is also provided, where the conservation of the different contacts is drawn in a grey scale. Finally, the interface area of the complex is monitored during the simulations. To show its utility, we used this novel approach to study two protein-protein complexes with interfaces of comparable size and both dominated by hydrophilic interactions, but having binding affinities at the extremes of the experimental range. MDcons is demonstrated to be extremely useful to analyse the MD trajectories of the investigated complexes, adding important insight into the dynamic behavior of their biological interface. Conclusions: MDcons specifically allows the user to highlight and characterize the dynamics of the interface in protein complexes and can thus be used as a complementary tool for the analysis of MD simulations of both experimental and predicted structures of protein complexes.

  10. Temporal growth factor release from platelet-rich plasma, trehalose lyophilized platelets, and bone marrow aspirate and their effect on tendon and ligament gene expression.

    Science.gov (United States)

    McCarrel, Taralyn; Fortier, Lisa

    2009-08-01

    Platelet-rich plasma (PRP) has generated substantial interest for tendon and ligament regeneration because of the high concentrations of growth factors in platelet alpha-granules. This study compared the temporal release of growth factors from bone marrow aspirate (BMA), PRP, and lyophilized platelet product (PP), and measured their effects on tendon and ligament gene expression. Blood and BMA were collected and processed to yield PRP and plasma. Flexor digitorum superficialis tendon (FDS) and suspensory ligament (SL) explants were cultured in 10% plasma in DMEM (control), BMA, PRP, or PP. TGF-beta1 and PDGF-BB concentrations were determined at 0, 24, and 96 h of culture using ELISA. Quantitative RT-PCR for collagen types I and III (COL1A1, COL3A1), cartilage oligomeric matrix protein (COMP), decorin, and matrix metalloproteinases-3 and 13 (MMP-3, MMP-13) was performed. TGF-beta1 and PDGF-BB concentrations were highest in PRP and PP. Growth factor quantity was unchanged in BMA, increased in PRP, and decreased in PP over 4 days. TGF-beta1 and platelet concentrations were positively correlated. Lyophilized PP and PRP resulted in increased COL1A1:COL3A1 ratio, increased COMP, and decreased MMP-13 expression. BMA resulted in decreased COMP and increased MMP-3 and MMP-13 gene expression. Platelet concentration was positively correlated with COL1A1, ratio of COL1A1:COL3A1, and COMP, and negatively correlated with COL3A1, MMP-13, and MMP-3. White blood cell concentration was positively correlated with COL3A1, MMP3, and MMP13, and negatively correlated with a ratio of COL1A1:COL3A1, COMP, and decorin. These findings support further in vivo investigation of PRP and PP for treatment of tendonitis and desmitis. Copyright 2009 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  11. Acromioclavicular joint reconstruction using a tendon graft: a biomechanical study comparing a novel “sutured throughout” tendon graft to a standard tendon graft

    Directory of Open Access Journals (Sweden)

    Naziri Qais

    2016-01-01

    Full Text Available Background: With a recurrence rate of over 30%, techniques that offer stronger acromioclavicular (AC joint reconstruction through increased graft strength may provide longevity. The purpose of our study was to determine the biomechanical strength of a novel tendon graft sutured throughout compared to a native tendon graft in Grade 3 anatomical AC joint reconstruction. Methods: For this in vitro experiment, nine paired (n = 18 embalmed cadaveric AC joints of three males and six females (age 86 years, range 51–94 years were harvested. Anatomic repair with fresh bovine Achilles tendon grafts without bone block was simulated. Specimens were divided into two groups; with group 1 using grafts with ultra-high molecular-weight polyethylene (UHMWPE suture ran throughout the entire length. In group 2, reconstruction with only native allografts was performed. The distal scapula and humerus were casted in epoxy compound and mounted on the mechanical testing machine. Tensile tests were performed using a mechanical testing machine at the rate of 50 mm/min. Maximum load and displacement to failure were collected. Results: The average load to failure was significantly higher for group 1 compared to group 2, with mean values of 437.5 N ± 160.7 N and 94.4 N ± 43.6 N, (p = 0.001. The average displacement to failure was not significantly different, with 29.7 mm ± 10.6 mm in group 1 and 25 mm ± 9.1 mm in group 2 (p = 0.25. Conclusion: We conclude that a UHMWPE suture reinforced graft can provide a 3.6 times stronger AC joint reconstruction compared to a native graft.

  12. Optical patient interface in femtosecond laser-assisted cataract surgery: contact corneal applanation versus liquid immersion.

    Science.gov (United States)

    Talamo, Jonathan H; Gooding, Philip; Angeley, David; Culbertson, William W; Schuele, Georg; Andersen, Daniel; Marcellino, George; Essock-Burns, Emma; Batlle, Juan; Feliz, Rafael; Friedman, Neil J; Palanker, Daniel

    2013-04-01

    To compare 2 optical patient interface designs used for femtosecond laser-assisted cataract surgery. Optimedica Corp., Santa Clara, California, USA, and Centro Laser, Santo Domingo, Dominican Republic. Experimental and clinical studies. Laser capsulotomy was performed during cataract surgery with a curved contact lens interface (CCL) or a liquid optical immersion interface (LOI). The presence of corneal folds, incomplete capsulotomy, subconjunctival hemorrhage, and eye movement during laser treatment were analyzed using video and optical coherence tomography. The induced rise of intraocular pressure (IOP) was measured in porcine and cadaver eyes. Corneal folds were identified in 70% of the CCL cohort; 63% of these had areas of incomplete capsulotomies beneath the corneal folds. No corneal folds or incomplete capsulotomies were identified in the LOI cohort. The mean eye movement during capsulotomy creation (1.5 sec) was 50 μm with a CCL and 20 μm with an LOI. The LOI cohort had 36% less subconjunctival hemorrhage than the CCL cohort. During suction, the mean IOP rise was 32.4 mm Hg ± 3.4 (SD) in the CCL group and 17.7 ± 2.1 mm Hg in the LOI group. Curved contact interfaces create corneal folds that can lead to incomplete capsulotomy during laser cataract surgery. A liquid interface eliminated corneal folds, improved globe stability, reduced subconjunctival hemorrhage, and lowered IOP rise. Copyright © 2013 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  13. 3D printed Ti6Al4V implant surface promotes bone maturation and retains a higher density of less aged osteocytes at the bone-implant interface.

    Science.gov (United States)

    Shah, Furqan A; Snis, Anders; Matic, Aleksandar; Thomsen, Peter; Palmquist, Anders

    2016-01-01

    For load-bearing orthopaedic applications, metal implants having an interconnected pore structure exhibit the potential to facilitate bone ingrowth and the possibility for reducing the stiffness mismatch between the implant and bone, thus eliminating stress-shielding effects. 3D printed solid and macro-porous Ti6Al4V implants were evaluated after six-months healing in adult sheep femora. The ultrastructural composition of the bone-implant interface was investigated using Raman spectroscopy and electron microscopy, in a correlative manner. The mineral crystallinity and the mineral-to-matrix ratios of the interfacial tissue and the native bone were found to be similar. However, lower Ca/P ratios, lower carbonate content, but higher proline, phenylalanine and tyrosine levels indicated that the interfacial tissue remained less mature. Bone healing was more advanced at the porous implant surface (vs. the solid implant surface) based on the interfacial tissue ν1 CO3(2-)/ν2 PO4(3-) ratio, phenylalanine and tyrosine levels approaching those of the native bone. The mechanosensing infrastructure in bone, the osteocyte lacuno-canalicular network, retained ∼40% more canaliculi per osteocyte lacuna, i.e., a 'less aged' morphology at the interface. The osteocyte density per mineralised surface area was ∼36-71% higher at the interface after extended healing periods. In osseointegration research, the success of an implant surface or design is commonly determined by quantifying the amount of new bone, rather than its maturation, composition and structure. This work describes a novel correlative methodology to investigate the ultrastructure and composition of bone formed around and within 3D printed Ti6Al4V implants having an interconnected open-pore structure. Raman spectroscopy demonstrates that the molecular composition of the interfacial tissue at different implant surfaces may vary, suggesting differences in the extent to which bone maturation occurs even after long

  14. Nature of the Ag-Si interface in screen-printed contacts. A detailed transmission electron microscopy study of cross-sectional structures

    Energy Technology Data Exchange (ETDEWEB)

    Ballif, C. [Fraunhofer ISE, Laboratory and Service Center Gelsenkirchen (Germany); Huljic, D.M.; Willeke, G. [Fraunhofer-Institut fuer Solare Energiesysteme (ISE), Freiburg im Breisgau (Germany); Hessler-Wyser, A. [Swiss Federal Inst. of Technology, CIME, Lausanne (Switzerland)

    2002-07-01

    As screen printed contacts are the predominant metallisation technique in industrial production of Si solar cells, a better understanding of their properties is necessary. In this work, we show that high-quality cross-sectional samples can be prepared, whose study by transmission electron microscopy (TEM) reveals precisely the structure of the contact between the silver fingers and the Si. On diffused [100] Si wafers, direct firing of an Ag paste results in interfaces which are mainly composed of shaped Ag crystallites penetrating the emitter up to 120 nm. These crystallites are in epitaxial relation with the Sl substrate. When firing the contacts through a SiN{sub x} layer, larger Ag crystallites are present at the interface with Si and the orientation relation is lost. In both cases, high resolution TEM imaging and EDX analyses reveal a crystalline Ag/Si interface, where neither oxide nor glass frit can be detected. The presence of a significant glass frit layer between the Ag crystallites contacting the Si and the large Ag grains forming the bulk of the fingers can partly explain why lowly doped emitters are difficult to contact by screen-printing. (orig.)

  15. A Novel Surgical Technique for Fixation of Recurrent Acromioclavicular Dislocations: AC Dog Bone Technique in Combination with Autogenous Semitendinosus Tendon Graft

    Directory of Open Access Journals (Sweden)

    Patrick Holweg

    2017-01-01

    Full Text Available Various surgical techniques have been described for the fixation of acromioclavicular (AC dislocations. However, recurrent dislocation is one of the main complications associated with the majority of these techniques. We report a case of postoperative AC joint redislocation. In order to overcome recurrent dislocation after revision surgery, a reconstruction of the conoid and trapezoid ligament with the use of a free tendon graft in combination with a FiberTape was provided within a novel surgical technique. After 12 months, the patient was very satisfied with the functional outcome. The patient achieved excellent results in the Constant (98 points, SPADI (0 points, and QuickDASH score (0 points. The described technique results in an anatomic reconstruction of the AC joint. The nonrigid nature of the intervention seems to restore the normal arthrokinematics by reconstructing the coracoclavicular ligaments with an autograft which is then protected by the AC Dog Bone artificial ligaments during the healing period. The arthroscopic approach to the AC joint with minimal exposure reduces the risks and complications of the intervention. This is the first case in literature that utilizes the artificial dog bone ligament securing the autograft in an anatomic AC reconstruction.

  16. Calcaneal tendon: imaging findings

    International Nuclear Information System (INIS)

    Montandon, Cristiano; Fonseca, Cristiano Rezio; Montandon Junior, Marcelo Eustaquio; Lobo, Leonardo Valadares; Ribeiro, Flavia Aparecida de Souza; Teixeira, Kim-Ir-Sen Santos

    2003-01-01

    We reviewed the radiological and clinical features of 23 patients with calcaneal tendon diseases, who were submitted to ultrasound or magnetic resonance imaging. The objective of this study was to characterize the lesions for a precise diagnosis of calcaneal tendon injuries. A wide range of calcaneal tendon diseases include degenerative lesions, inflammation of the peritendinous tissue such as peritendinitis and bursitis, and rupture. Imaging methods are essential in the diagnosis, treatment and follow-up of calcaneal tendon diseases. (author)

  17. X-ray phase contrast imaging of the bone-cartilage interface

    International Nuclear Information System (INIS)

    Ismail, E.C.; Kaabar, W.; Garrity, D.; Gundogdu, O.; Bradley, D.A.; Bunk, O.; Pfeiffer, F.; Farquharson, M.J.

    2008-01-01

    Full text: Synovial joints articulate in a lubricating environment, the system providing for smooth articulation. The articular cartilage overlying the bone consists of a network of collagen fibres. This network is essential to cartilage integrity, suffering damage in degenerative joint disease such as osteoarthritis. At Surrey and also in work conducted by this group at the Paul Scherrer Institute (PSI) synchrotron site we have been applying a number of techniques in studying the bone-cartilage interface and of changes occurring in this with disease. One technique attracting particular interest is X-ray phase contrast imaging, yielding information on anatomical features that manifest from the large scale organisation of collagen and the mineralised phase contained within the collagen fibres in the deep cartilage zone. This work will briefly review some of the basic supporting physics and then shows some of the images and other results that we have obtained to-date

  18. Containment structure tendon investigation

    International Nuclear Information System (INIS)

    Fulton, J.F.; Murray, K.H.

    1983-01-01

    The paper describes an investigation into the possible causes of lower-than-predicted tendon forces which were measured during past tendon surveillances for a concrete containment. The containment is post tensioned by vertical tendons which are anchored into a rock foundation. The tendons were originally stressed in 1969, and lift-off tests were performed on six occasions subsequent to this date over a period of 11 years. The tendon forces measured in these tests were generally lower than predicted, and by 1979 the prestress level in the containment was only marginally above the design requirement. The tendons were retensioned in 1980, and by this time an investigation into the possible causes was underway. Potential causes investigated include the rock anchors and surrounding rock, elastomeric pad creep, wire stresses, thermal effects, stressing equipment and lift-off procedures, and wire stress relaxation. The investigation activities included stress relaxation testing of wires pulled from actual tendons. The stress relaxation test program included wire specimens at several different temperature and initial stress levels and the effect of a varying temperature history on the stress relaxation property of the wires. For purpose of future force predictions of the retensioned tendons, the test program included tests to determine the effect on stress relaxation due to restressing the wires after they had relaxed for 1000 hours and 10,000 hours. (orig./GL)

  19. Highly Unusual Tendon Abnormality: Spontaneous Rupture of the Distal Iliopsoas Tendon

    Directory of Open Access Journals (Sweden)

    Gokcen Coban

    2014-06-01

    Full Text Available Iliopsoas tendon injuries are not common and usually occur due to avulsion of the iliopsoas tendon with detachment of the lesser trochanter, secondary to an athletic injury or trauma. In the absence of a trauma, avulsion of the lesser trochanter in an adult is regarded as a sign of metastatic disease until proven otherwise. Complete iliopsoas tendon tears have thus far only been described in elderly women, and without trauma or an underlying systemic disease, a hormonal basis may be a reason for the gender differences. In this article, we present an 87-year-old woman with spontaneous rupture of the left distal iliopsoas tendon unassociated with fracture of the lesser trochanter and in the absence of a recent trauma history. This elderly patient presented with acute groin pain and normal plain radiographs. Magnetic resonance imaging must be kept in mind as a modality of choice for identifying iliopsoas tendon abnormalities.

  20. Treatment of acute achilles tendon rupture with the panda rope bridge technique.

    Science.gov (United States)

    Yin, Liangjun; Wu, Yahong; Ren, Changsong; Wang, Yizhong; Fu, Ting; Cheng, Xiangjun; Li, Ruidong; Nie, Mao; Mu, Yuan

    2018-03-01

    Although nonsurgical methods and many surgical techniques have been developed for repairing a ruptured Achilles tendon, there is no consensus on its best treatment. In this article, a novel minimally invasive technique called the Panda Rope Bridge Technique (PRBT) is described. Patient with acute Achilles tendon rupture was operated on in the prone position. The PRBT begin with making the proximal bridge anchor (Krackow sutures in the myotendinous junction), the distal bridge anchor (two suture anchors in the calcaneus bone) and the ropes (threads of the suture anchors) stretched between the anchor sites. Then a small incision was made to debride and reattach the stumps of ruptured tendon. After the surgery, no cast or splint fixation was applied. All patients performed enhanced recovery after surgery (ERAS), which included immediate ankle mobilisation from day 1, full weight-bearing walking from day 5 to 7, and gradually take part in athletic exercises from 8 weeks postoperatively. PBRT was performed in 11patients with acute Achilles tendon rupture between June 2012 and June 2015. No wound infection, fistula, skin necrosis, sural nerve damage, deep venous thrombosis or tendon re-rupture was found. One year after the surgery, all patients reported 100 AOFAS ankle-hindfoot score points and the mean ATRS was 96.6. The PRBT is a simple, effective and minimally invasive technique, with no need for immobilisation of the ankle, making possible immediate and aggressive postoperative rehabilitation. Copyright © 2018 Elsevier Ltd. All rights reserved.

  1. Evaluation of Heat Transfer to the Implant-Bone Interface During Removal of Metal Copings Cemented onto Titanium Abutments.

    Science.gov (United States)

    Cakan, Umut; Cakan, Murat; Delilbasi, Cagri

    2016-01-01

    The aim of this investigation was to measure the temperature increase due to heat transferred to the implant-bone interface when the abutment screw channel is accessed or a metal-ceramic crown is sectioned buccally with diamond or tungsten carbide bur using an air rotor, with or without irrigation. Cobalt-chromium copings were cemented onto straight titanium abutments. The temperature changes during removal of the copings were recorded over a period of 1 minute. The sectioning of coping with diamond bur and without water irrigation generated the highest temperature change at the cervical part of the implant. Both crown removal methods resulted in an increase in temperature at the implant-bone interface. However, this temperature change did not exceed 47°C, the potentially damaging threshold for bone reported in the literature.

  2. [Achilles tendon rupture].

    Science.gov (United States)

    Thermann, H; Hüfner, T; Tscherne, H

    2000-03-01

    The treatment of acute of Achilles tendon rupture experienced a dynamic development in the last ten years. Decisive for this development was the application of MRI and above all the ultrasonography in the diagnostics of the pathological changes and injuries of tendons. The question of rupture morphology as well as different courses of healing could be now evaluated objectively. These advances led consequently to new modalities in treatment concepts and rehabilitation protocols. The decisive input for improvements of the outcome results and particularly the shortening of the rehabilitation period came with introduction of the early functional treatment in contrast to immobilizing plaster treatment. In a prospective randomized study (1987-1989) at the Trauma Dept. of the Hannover Medical School could show no statistical differences comparing functional non-operative with functional operative therapy with a special therapy boot (Variostabil/Adidas). The crucial criteria for therapy selection results from the sonographically measured position of the tendon stumps in plantar flexion (20 degrees). With complete adaptation of the tendons' ends surgical treatment does not achieve better results than non-operative functional treatment in term of tendon healing and functional outcome. Regarding the current therapeutic standards each method has is advantages and disadvantages. Both, the operative and non-operative functional treatment enable a stable tendon healing with a low risk of re-rupture (1-2%). Meanwhile there is consensus for early functional after-treatment of the operated Achilles' tendons. There seems to be a trend towards non-operative functional treatment in cases of adequate sonographical findings, or to minimal invasive surgical techniques.

  3. Elemental and structural studies at the bone-cartilage interface

    Energy Technology Data Exchange (ETDEWEB)

    Kaabar, W., E-mail: w.kaabar@surrey.ac.uk [Department of Physics, University of Surrey, Guildford GU2 7XH (United Kingdom); Daar, E. [Department of Physics, University of Surrey, Guildford GU2 7XH (United Kingdom); Bunk, O. [Swiss Light Source, Paul Scherrer Institute, 5232 Villigen (Switzerland); Farquharson, M.J. [Department of Medical Physics and Applied Radiation Sciences, McMaster University, 1280 Main Street West, Hamilton, Ontario, L8S 4K1 (Canada); Laklouk, A. [Al-Fateh University, Tripoli (Libya); Bailey, M.; Jeynes, C. [Surrey Ion Beam Centre, University of Surrey, Guildford GU2 7XH (United Kingdom); Gundogdu, O. [Umuttepe Campus, University of Kocaeli, 41380 Kocaeli (Turkey); Bradley, D.A. [Department of Physics, University of Surrey, Guildford GU2 7XH (United Kingdom)

    2011-10-01

    Micro-Proton Induced X-ray Emission ({mu}-PIXE) and Proton Induced Gamma-ray Emission (PIGE) techniques were employed in the investigation of trace and essential elements distribution in normal and diseased human femoral head sections affected by osteoarthritis (OA). PIGE was exploited in the determination of elements of low atomic number z<15 such as Na and F whereas elements with z>15 viz Ca, Z, P and S were determined by PIXE. Accumulations of key elements in the bone and cartilage sections were observed, significant S and Na concentrations being found in the cartilage region particularly in normal tissues. Zn showed enhanced concentrations at the bone-cartilage interface. At a synchrotron facility, small angle X-ray scattering (SAXS) was utilized on a decalcified human femoral head section affected by OA, direct measurements being made of spatial alterations of collagen fibres. The SAXS results showed a slight decrease in the axial periodicity between normal collagen type I and that in diseased tissue in various sites, in contrast with the findings of others.

  4. Ropivacaine alters the mechanical properties of hamstring tendons: In vitro controlled mechanical testing of tendons from living donors.

    Science.gov (United States)

    Ollivier, M; Sbihi, J; Sbihi, A; Pithioux, M; Parratte, S; Argenson, J-N

    2017-11-01

    Intraarticular or periarticular injection of ropivacaine (RI) is an element of current knee surgery practices. The goal of this study was to determine the effects of RI on the mechanical properties of hamstring tendons. We hypothesized that RI would have a detrimental effect on the mechanical properties of periarticular soft tissues METHODS: A tensile test to failure was performed on 120 hamstring tendon segments harvested during ACL reconstruction surgery in 120 patients. Two sets of tensile tests were done. The first evaluated the effect of RI itself on the mechanical properties of tendons: 30 samples were soaked for 1hour in a 2% RI solution and compared to 30 samples soaked in a saline solution (control group). The second evaluated the effect of RI concentration on the mechanical properties of hamstring tendons: 30 samples were soaked for 1hour in a 2% RI solution and 30 samples were soaked in a 7.5% RI solution. In the first test, 29 samples from each group were analyzed as two samples (one in each group) failed at the grip interface. The specimens exposed to 2% RI had lower ultimate tensile strength (Δ=4.4MPa, P=0.001), strain energy (Δ=13MPa, P=0.001) and Young's modulus (Δ=1.6MPa, P=0.02) than the specimens in the control group. There was no significant difference in the strain at failure between groups (Δ=5%, P=0.3). In the second test, one specimen from the 7.5% RI group failed during the preloading and was excluded. There was no significant difference in terms of the load at failure and ultimate tensile stress (Δ=0.45MPa, P=0.6) and strain energy (Δ=0.49MPa, P=0.49) between the two groups. There were significant differences in terms of elongation at failure (Δ=28%, P=0.0003) and Young's modulus (Δ=2.6MPa, P=0.005), with the specimens exposed to 7.5% RI undergoing greater deformation and having a lower Young's modulus. While local RI injections are widely performed in clinical practice, the results of this in vitro study point to short

  5. Preparation and investigation of burried metal/molecule contact interfaces with surface sensitive methods; Praeparation und Untersuchung verborgener Metall/Molekuel-Kontaktgrenzflaechen mit oberflaechensensitiven Methoden

    Energy Technology Data Exchange (ETDEWEB)

    Vrdoljak, Pavo

    2011-05-13

    The present thesis establishes an optimised concept of a delamination technique suitable for ultra high vacuum (UHV) with which model systems of buried interfaces were made accessible for surface sensitive methods which were applied to investigate their electronic and topographical properties. A primary focus of this work is on the question how buried interfaces could be accessed successfully for surface sensitive methods using buried metal/NTCDA and metal/PTCDA interfaces as model systems. Contacts of approximately 10 x 15 mm{sup 2} in size were accessed. The second focus of the thesis is on the investigation of the electronical and topographical properties of the buried interfaces, for which some similarities between delaminated metal (Au,Ag)/ PTCDA- and Ag/NTCDA interfaces were found: After the delamination of top-contacts there were inhomogeneous layers of molecules on the metal contacts. Whereas PTCDA covered metal contacts had thicker molecular layers (4-5 ML PTCDA on Ag), NTCDA covered contacts showed only one monolayer coverage over large areas of at least 2 mm in diameter. Regions with multilayer coverage showed smooth surfaces whereas metal surfaces showed a fissured, meander-like and rough surface. Both contact systems also had in common that the adhesive made PES investigations of valence states very difficult. Furthermore, it was possible to thin out the molecular layers thermally but afterwards no valence states could be measured. Investigating in-situ delaminated buried interfaces, the focus was on metal (Au,Ag)/PTCDA interfaces first. The molecular layers could be successfully desorbed thermally at 260 C to 1-3 monolayers so that valence states were investigated. The spectra of the in-situ delaminated and thermally desorbed Ag/PTCDA contact were noticeably broadened so that the positions of HOMO and FLUMO could only be estimated at 1.9 eV and 0.7 eV, respectively. Additionally, interfaces of Ag/NTCDA contacts were investigated. With UPS it was found

  6. Structural tendon changes in patients with acromegaly: assessment of Achilles tendon with sonoelastography.

    Science.gov (United States)

    Onal, Eda Demil; Ipek, Ali; Evranos, Berna; Idilman, Ilkay Sedakat; Cakir, Bekir; Ersoy, Reyhan

    2016-03-01

    To describe the sonoelastographic appearance of the Achilles tendon in acromegalic patients and to determine whether the blood concentrations of growth hormone (GH) and insulin-like growth factor (IGF-1) are associated with the various sonographic elasticity types of Achilles tendons. Eighty-four Achilles tendons of 42 acromegaly patients and 84 Achilles tendons of 42 healthy volunteers were assessed with sonoelastography. The tendons were classified into two main types according to the elasticity features: type 1 blue/green (hard tissue) and type 2 yellow/red within green (intermediate-soft tissue). Two subtypes of these types were also defined. According to the definition, the elasticity of the tissue was in a spectrum ranging from hard to soft as the type progressed from 1a to 2b. The mean thickness of Achilles tendons in patients with acromegaly was significantly higher compared with healthy Achilles tendons (5.1+/-0.7 mm vs. 4.4+/-0.5, pacromegaly patients had type 2 sonoelastographic appearance of the Achilles tendon (124/252 third; 49.2% vs. 81/252 third; 32.1%, p=0.0001). Activity status of acromegaly and GH/IGF-I levels were similar in patients with different types of elasticity (p>0.05). Sonoelastography revealed structural changes in the tendinous tissue of patients with acromegaly, but it was not sensitive enough to reflect changes in the serum levels of GH/IGF-1.

  7. Peri-implant stress correlates with bone and cement morphology: Micro-FE modeling of implanted cadaveric glenoids.

    Science.gov (United States)

    Wee, Hwabok; Armstrong, April D; Flint, Wesley W; Kunselman, Allen R; Lewis, Gregory S

    2015-11-01

    Aseptic loosening of cemented joint replacements is a complex biological and mechanical process, and remains a clinical concern especially in patients with poor bone quality. Utilizing high resolution finite element analysis of a series of implanted cadaver glenoids, the objective of this study was to quantify relationships between construct morphology and resulting mechanical stresses in cement and trabeculae. Eight glenoid cadavers were implanted with a cemented central peg implant. Specimens were imaged by micro-CT, and subject-specific finite element models were developed. Bone volume fraction, glenoid width, implant-cortex distance, cement volume, cement-cortex contact, and cement-bone interface area were measured. Axial loading was applied to the implant of each model and stress distributions were characterized. Correlation analysis was completed across all specimens for pairs of morphological and mechanical variables. The amount of trabecular bone with high stress was strongly negatively correlated with both cement volume and contact between the cement and cortex (r = -0.85 and -0.84, p implant-cortex distance. Contact between the cement and underlying cortex may dramatically reduce trabecular bone stresses surrounding the cement, and this contact depends on bone shape, cement amount, and implant positioning. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  8. Energy level alignment and molecular conformation at rubrene/Ag interfaces: Impact of contact contaminations on the interfaces

    Energy Technology Data Exchange (ETDEWEB)

    Sinha, Sumona, E-mail: sumona.net.09@gmail.com [Saha Institute of Nuclear Physics, 1/AF, Bidhannagar, Kolkata 700064 (India); Wang, C.-H. [National Synchrotron Radiation Research Center, Hsinchu 30076, Taiwan (China); Mukherjee, M. [Saha Institute of Nuclear Physics, 1/AF, Bidhannagar, Kolkata 700064 (India)

    2017-07-01

    Highlights: • Impact of contact contaminations on the energy level alignment and molecular conformation at rubrene/Ag interfaces. • Adventitious contamination layer was acted as a spacer layer between Ag substrate surface and rubrene molecular layer. • Hole injection barrier height and interface dipole at rubrene/Ag interfaces depend on the cleanliness of Ag substrate. • Molecular conformation as well as orientation controlled by the cleanliness of Ag surface. • Resulted different surface morphology of rubrene thin films on unclean and clean Ag substrate. - Abstract: This paper addresses the impact of electrode contaminations on the interfacial energy level alignment, the molecular conformation, orientation and surface morphology deposited organic film at organic semiconductor/noble metal interfaces by varying of film thickness from sub-monolayer to multilayer, which currently draws significant attention with regard to its application in organic electronics. The UHV clean Ag and unclean Ag were employed as substrate whereas rubrene was used as an organic semiconducting material. The photoelectron spectroscopy (XPS and UPS) was engaged to investigate the evolution of interfacial energetics; polarization dependent near edge x-ray absorption fine structure spectroscopy (NEXAFS) was employed to understand the molecular conformation as well as orientation whereas atomic force microscopy (AFM) was used to investigate the surface morphologies of the films. The adventitious contamination layer was acted as a spacer layer between clean Ag substrate surface and rubrene molecular layer. As a consequence, hole injection barrier height, interface dipole as well as molecular-conformation, molecular-orientation and surface morphology of rubrene thin films were found to depend on the cleanliness of Ag substrate. The results have important inferences about the understanding of the impact of substrate contamination on the energy level alignment, the molecular conformation

  9. MRI of tibialis anterior tendon rupture

    International Nuclear Information System (INIS)

    Gallo, Robert A.; DeMeo, Patrick J.; Kolman, Brett H.; Daffner, Richard H.; Sciulli, Robert L.; Roberts, Catherine C.

    2004-01-01

    Ruptures of the tibialis anterior tendon are rare. We present the clinical histories and MRI findings of three recent male patients with tibialis anterior tendon rupture aged 58-67 years, all of whom presented with pain over the dorsum of the ankle. Two of the three patients presented with complete rupture showing discontinuity of the tendon, thickening of the retracted portion of the tendon, and excess fluid in the tendon sheath. One patient demonstrated a partial tear showing an attenuated tendon with increased surrounding fluid. Although rupture of the tibialis anterior tendon is a rarely reported entity, MRI is a useful modality in the definitive detection and characterization of tibialis anterior tendon ruptures. (orig.)

  10. Histological Changes in the Proximal and Distal Tendon Stumps Following Transection of Achilles Tendon in the Rabbits.

    Science.gov (United States)

    Al-Qattan, Mohammad M; Mawlana, Ola Helmi; Mohammed Ahmed, Raeesa Abdel-Twab; Hawary, Khalid

    2016-05-01

    To determine tendon stump changes following unrepaired Achilles tendon lacerations in an animal model. An experimental study. King Saud University, Riyadh, Saudi Arabia, from October 2013 to January 2014. Arabbit model was developed and studied tendon retraction and histological changes in the proximal and distal stumps following transection of the Achilles tendon. Over a period of 12 weeks, retraction of the distal tendon stump was minimal (2 - 3 mm). In contrast, retraction of the proximal tendon stump peaked to reach 6 mm at 4 weeks post-injury and plateaued to reach 7 - 8 mm at the 12-week interval. Following complete transection of the Achilles tendon, tendon retraction correlated with the density of myofibroblast expression within the tendon stump. Further research is needed to investigate the pathophysiology of these findings.

  11. Novel methods for tendon investigations

    DEFF Research Database (Denmark)

    Kjær, Michael; Langberg, Henning; Bojsen-Møller, J.

    2008-01-01

    Purpose. Tendon structures have been studied for decades, but over the last decade, methodological development and renewed interest for metabolic, circulatory and tissue protein turnover in tendon tissue has resulted in a rising amount of investigations. Method. This paper will detail the various...... modern investigative techniques available to study tendons. Results. There are a variety of investigative methods available to study the correlations between mechanics and biology in tendons. Conclusion. The available methodologies not only allow for potential insight into physiological...... and pathophysiological mechanisms in tendon tissue, but also, to some extent, allow for more elaborate studies of the intact human tendon. Read More: http://informahealthcare.com/doi/full/10.1080/09638280701785403...

  12. Bone anchors or interference screws? A biomechanical evaluation for autograft ankle stabilization.

    Science.gov (United States)

    Jeys, Lee; Korrosis, Sotiris; Stewart, Todd; Harris, Nicholas J

    2004-01-01

    Autograft stabilization uses free semitendinosus tendon grafts to anatomically reconstruct the anterior talofibular ligament. Study aims were to evaluate the biomechanical properties of Mitek GII anchors compared with the Arthrex Bio-Tenodesis Screw for free tendon reconstruction of the anterior talofibular ligament. There are no differences in load to failure and percentage specimen elongation at failure between the 2 methods. Controlled laboratory study using porcine models. Sixty porcine tendon constructs were failure tested. Re-creating the pull of the anterior talofibular ligament, loads were applied at 70 degrees to the bones. Thirty-six tendons were fixed to porcine tali and tested using a single pull to failure; 10 were secured with anchors and No. 2 Ethibond, 10 with anchors and FiberWire, 10 with screws and Fiberwire, and 6 with partially gripped screws. Cyclic preloading was conducted on 6 tendons fixed by anchors and on 6 tendons fixed by screws before failure testing. Two groups of 6 components fixed to the fibula were also tested. The talus single-pull anchor group produced a mean load of 114 N and elongation of 37% at failure. The talus single-pull screw group produced a mean load of 227 N and elongation of 22% at failure (P anchors. The improved biomechanics of interference screws suggests that these may be more suited to in vivo reconstruction of the anterior talofibular ligament than are bone anchors.

  13. Tendon 'turnover lengthening' technique.

    Science.gov (United States)

    Cerovac, S; Miranda, B H

    2013-11-01

    Tendon defect reconstruction is amongst the most technically challenging areas in hand surgery. Tendon substance deficiency reconstruction techniques include lengthening, grafting, two-stage reconstruction and tendon transfers, however each is associated with unique challenges over and above direct repair. We describe a novel 'turnover lengthening' technique for hand tendons that has successfully been applied to the repair of several cases, including a case of attritional flexor and traumatic extensor tendon rupture in two presented patients where primary tenorrhaphy was not possible. In both cases a good post-operative outcome was achieved, as the patients were happy having returned back to normal activities of daily living such that they were discharged 12 weeks post-operatively. Our technique avoids the additional morbidity and complications associated with grafting, transfers and two stage reconstructions. It is quick, simple and reproducible for defects not exceeding 3-4 cm, provides a means of immediate one stage reconstruction, no secondary donor site morbidity and does not compromise salvage by tendon transfer and/or two-stage reconstruction in cases of failure. To our knowledge no such technique has been previously been described to reconstruct such hand tendon defects. Crown Copyright © 2013. Published by Elsevier Ltd. All rights reserved.

  14. Thermal contact conductance of metallic coated BiCaSrCuO superconductor/copper interfaces at cryogenic temperatures

    International Nuclear Information System (INIS)

    Ochterbeck, J.M.; Peterson, G.P.; Fletcher, L.S.

    1992-01-01

    The effects of vapor deposited coatings on the thermal contact conductance of cold pressed, normal state BiCaSrCuO superconductor/oxygen-free copper interfaces were experimentally investigated over a pressure range of 200 to 2,000 kPa. Using traditional vapor deposition processes, thin coatings of indium or lead were applied to the superconductor material to determine the effect on the heat transfer occurring at the interface. The test data indicate that the contact conductance can be enhanced using these coatings, with indium providing the greater enhancement. The experimental program revealed the need for a better understanding and control of the vapor deposition process when using soft metallic coatings. Also, the temperature-dependent microhardness of copper was experimentally determined and found to increase by approximately 35 percent as the temperature decreased from 300 to 85 K. An empirical model was developed to predict the effect of soft coatings on the thermal contact conductance of the superconductor/copper interfaces. When applied, the model agreed well with the data obtained in this investigation at low coating thicknesses but overpredicted the data as the thickness increased. In addition, the model agreed very well with data obtained in a previous investigation for silvercoated nickel substrates at all coating thicknesses

  15. Tenomodulin is Required for Tendon Endurance Running and Collagen I Fibril Adaptation to Mechanical Load

    Directory of Open Access Journals (Sweden)

    Sarah Dex

    2017-06-01

    Full Text Available Tendons are dense connective tissues that attach muscles to bone with an indispensable role in locomotion because of their intrinsic properties of storing and releasing muscle- generated elastic energy. Tenomodulin (Tnmd is a well-accepted gene marker for the mature tendon/ligament lineage and its loss-of -function in mice leads to a phenotype with distinct signs of premature aging on tissue and stem/progenitor cell levels. Based on these findings, we hypothesized that Tnmd might be an important factor in the functional performance of tendons. Firstly, we revealed that Tnmd is a mechanosensitive gene and that the C-terminus of the protein co-localize with collagen I-type fibers in the extracellular matrix. Secondly, using an endurance training protocol, we compared Tnmd knockout mice with wild types and showed that Tnmd deficiency leads to significantly inferior running performance that further worsens with training. In these mice, endurance running was hindered due to abnormal response of collagen I cross-linking and proteoglycan genes leading to an inadequate collagen I fiber thickness and elasticity. In sum, our study demonstrates that Tnmd is required for proper tendon tissue adaptation to endurance running and aids in better understanding of the structural-functional relationships of tendon tissues.

  16. Histological Changes in the Proximal and Distal Tendon Stumps Following Transection of Achilles Tendon in the Rabbits

    International Nuclear Information System (INIS)

    Al-Qattan, M. M.; Hawary, K.; Mawlana, O. H.; Ahmed, R. A. M.

    2016-01-01

    Objective: To determine tendon stump changes following unrepaired Achilles tendon lacerations in an animal model. Study Design: An experimental study. Place and Duration of Study: King Saud University, Riyadh, Saudi Arabia, from October 2013 to January 2014. Methodology: Arabbit model was developed and studied tendon retraction and histological changes in the proximal and distal stumps following transection of the Achilles tendon. Result: Over a period of 12 weeks, retraction of the distal tendon stump was minimal (2 - 3 mm). In contrast, retraction of the proximal tendon stump peaked to reach 6 mm at 4 weeks post-injury and plateaued to reach 7 - 8 mm at the 12-week interval. Conclusion: Following complete transection of the Achilles tendon, tendon retraction correlated with the density of myofibroblast expression within the tendon stump. Further research is needed to investigate the pathophysiology of these findings. (author)

  17. Serial superficial digital flexor tendon biopsies for diagnosing and monitoring collagenase-induced tendonitis in horses

    Directory of Open Access Journals (Sweden)

    José C. de Lacerda Neto

    2013-06-01

    Full Text Available The purpose of this investigation was to demonstrate the feasibility of a biopsy technique by performing serial evaluations of tissue samples of the forelimb superficial digital flexor tendon (SDFT in healthy horses and in horses subjected to superficial digital flexor tendonitis induction. Eight adult horses were evaluated in two different phases (P, control (P1 and tendonitis-induced (P2. At P1, the horses were subjected to five SDFT biopsies of the left forelimb, with 24 hours (h of interval. Clinical and ultrasonographic (US examinations were performed immediately before the tendonitis induction, 24 and 48 h after the procedure. The biopsied tendon tissues were analyzed through histology. P2 evaluations were carried out three months later, when the same horses were subjected to tendonitis induction by injection of bacterial collagenase into the right forelimb SDFT. P2 clinical and US evaluations, and SDFT biopsies were performed before, and after injury induction at the following time intervals: after 24, 48, 72 and 96 h, and after 15, 30, 60, 90, 120 and 150 days. The biopsy technique has proven to be easy and quick to perform and yielded good tendon samples for histological evaluation. At P1 the horses did not show signs of localised inflammation, pain or lameness, neither SDFT US alterations after biopsies, showing that the biopsy procedure per se did not risk tendon integrity. Therefore, this procedure is feasible for routine tendon histological evaluations. The P2 findings demonstrate a relation between the US and histology evaluations concerning induced tendonitis evolution. However, the clinical signs of tendonitis poorly reflected the microscopic tissue condition, indicating that clinical presentation is not a reliable parameter for monitoring injury development. The presented method of biopsying SDFT tissue in horses enables the serial collection of material for histological analysis causing no clinical signs and tendon damage seen

  18. Sex Hormones and Tendon

    DEFF Research Database (Denmark)

    Hansen, Mette; Kjaer, Michael

    2016-01-01

    The risk of overuse and traumatic tendon and ligament injuries differ between women and men. Part of this gender difference in injury risk is probably explained by sex hormonal differences which are specifically distinct during the sexual maturation in the teenage years and during young adulthood....... The effects of the separate sex hormones are not fully elucidated. However, in women, the presence of estrogen in contrast to very low estrogen levels may be beneficial during regular loading of the tissue or during recovering after an injury, as estrogen can enhance tendon collagen synthesis rate. Yet...... has also been linked to a reduced responsiveness to relaxin. The present chapter will focus on sex difference in tendon injury risk, tendon morphology and tendon collagen turnover, but also on the specific effects of estrogen and androgens....

  19. Frictional Compliant Haptic Contact and Deformation of Soft Objects

    Directory of Open Access Journals (Sweden)

    Naci Zafer

    2016-05-01

    Full Text Available This paper is concerned with compliant haptic contact and deformation of soft objects. A human soft fingertip model is considered to act as the haptic interface and is brought into contact with and deforms a discrete surface. A nonlinear constitutive law is developed in predicting normal forces and, for the haptic display of surface texture, motions along the surface are also resisted at various rates by accounting for dynamic Lund-Grenoble (LuGre frictional forces. For the soft fingertip to apply forces over an area larger than a point, normal and frictional forces are distributed around the soft fingertip contact location on the deforming surface. The distribution is realized based on a kernel smoothing function and by a nonlinear spring-damper net around the contact point. Experiments conducted demonstrate the accuracy and effectiveness of our approach in real-time haptic rendering of a kidney surface. The resistive (interaction forces are applied at the user fingertip bone edge. A 3-DoF parallel robotic manipulator equipped with a constraint based controller is used for the implementation. By rendering forces both in lateral and normal directions, the designed haptic interface system allows the user to realistically feel both the geometrical and mechanical (nonlinear properties of the deforming kidney.

  20. Changes in Achilles tendon mechanical properties following eccentric heel drop exercise are specific to the free tendon.

    Science.gov (United States)

    Obst, S J; Newsham-West, R; Barrett, R S

    2016-04-01

    Mechanical loading of the Achilles tendon during isolated eccentric contractions could induce immediate and region-dependent changes in mechanical properties. Three-dimensional ultrasound was used to examine the immediate effect of isolated eccentric exercise on the mechanical properties of the distal (free tendon) and proximal (gastrocnemii) regions of the Achilles tendon. Participants (n = 14) underwent two testing sessions in which tendon measurements were made at rest and during a 30% and 70% isometric plantar flexion contractions immediately before and after either: (a) 3 × 15 eccentric heel drops or (b) 10-min rest. There was a significant time-by-session interaction for free tendon length and strain for all loading conditions (P tendon length and strain at all contraction intensities after eccentric exercise (P tendon for any of the measured parameters. Immediate changes in Achilles tendon mechanical properties were specific to the free tendon and consistent with changes due to mechanical creep. These findings suggest that the mechanical properties of the free tendon may be more vulnerable to change with exercise compared with the gastrocnemii aponeurosis or tendon. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  1. High volume ultrasound guided injections at the interface between the patellar tendon and Hoffa's body are effective in chronic patellar tendinopathy: A pilot study.

    Science.gov (United States)

    Crisp, Tom; Khan, Faisal; Padhiar, Nat; Morrissey, Dylan; King, John; Jalan, Rosy; Maffulli, Nicola; Frcr, Otto Chan

    2008-01-01

    To evaluate a novel conservative management modality for patellar tendinopathy. We recruited nine patients with patellar tendinopathy who had failed conservative management and showed evidence of neovascularisation on power Doppler scanning. A high volume ultrasound guided injection at the interface between the patellar tendon and Hoffa's body. The injection contained 10 ml 0.5% Bupivacaine, 25 mg Hydrocortisone, and between 12 and 40 ml normosaline. 100 mm visual analogue scales (VAS) for pain and for function, and Victorian Institute of Sport Assessment - Patellar tendon (VISA-P) questionnaires at an average of 9 months from the injection. All but one patient (whose pain was unchanged) improved (p = 0.028). The mean improvement in function 2 weeks after injection was 58 mm on VAS (interquartile range 27 - 88, p = 0.018). The mean improvement in pain 2 weeks after injection was 56 mm on a VAS scale (interquartile range 32 - 80, p = 0.018). At a mean follow up of 9 months, an improvement of 22 points from a baseline score of 46 on the VISA-P questionnaire (100 being normal) was established. High volume injections to mechanically disrupt the neovascularisation in patellar tendinopathy are helpful in the management of this condition. Controlled trials would be warranted to investigate in a more conclusive fashion this management modality.

  2. Fluoroquinolones impair tendon healing in a rat rotator cuff repair model: a preliminary study.

    Science.gov (United States)

    Fox, Alice J S; Schär, Michael O; Wanivenhaus, Florian; Chen, Tony; Attia, Erik; Binder, Nikolaus B; Otero, Miguel; Gilbert, Susannah L; Nguyen, Joseph T; Chaudhury, Salma; Warren, Russell F; Rodeo, Scott A

    2014-12-01

    Recent studies suggest that fluoroquinolone antibiotics predispose tendons to tendinopathy and/or rupture. However, no investigations on the reparative capacity of tendons exposed to fluoroquinolones have been conducted. Fluoroquinolone-treated animals will have inferior biochemical, histological, and biomechanical properties at the healing tendon-bone enthesis compared with controls. Controlled laboratory study. Ninety-two rats underwent rotator cuff repair and were randomly assigned to 1 of 4 groups: (1) preoperative (Preop), whereby animals received fleroxacin for 1 week preoperatively; (2) pre- and postoperative (Pre/Postop), whereby animals received fleroxacin for 1 week preoperatively and for 2 weeks postoperatively; (3) postoperative (Postop), whereby animals received fleroxacin for 2 weeks postoperatively; and (4) control, whereby animals received vehicle for 1 week preoperatively and for 2 weeks postoperatively. Rats were euthanized at 2 weeks postoperatively for biochemical, histological, and biomechanical analysis. All data were expressed as mean ± standard error of the mean (SEM). Statistical comparisons were performed using either 1-way or 2-way ANOVA, with P repair response that has potential clinical implications for patients who are exposed to fluoroquinolones before tendon repair surgery. © 2014 The Author(s).

  3. Finite element analysis of the contact interface between trans-femoral stump and prosthetic socket.

    Science.gov (United States)

    Zhang, Linlin; Zhu, Ming; Shen, Ling; Zheng, Feng

    2013-01-01

    Transfemoral amputees need prosthetic devices after amputation surgery, and the interface pressure between the residual limb and prosthetic socket has a significant effect on an amputee's satisfaction and comfort. The purpose of this study was to build a nonlinear finite element model to investigate the interface pressure between the above-knee residual limb and its prosthetic socket. The model was three-dimensional (3D) with consideration of nonlinear boundary conditions. Contact analysis was used to simulate the friction conditions between skin and the socket. The normal stresses up to 80.57 kPa at the distal end of the soft tissue. The longitudinal and circumferential shear stress distributions at the limb-socket interface were also simulated. This study explores the influences of load transfer between trans-femoral residual limb and its prosthetic socket.

  4. Does PEEK/HA Enhance Bone Formation Compared With PEEK in a Sheep Cervical Fusion Model?

    Science.gov (United States)

    Walsh, William R; Pelletier, Matthew H; Bertollo, Nicky; Christou, Chris; Tan, Chris

    2016-11-01

    Polyetheretherketone (PEEK) has a wide range of clinical applications but does not directly bond to bone. Bulk incorporation of osteoconductive materials including hydroxyapatite (HA) into the PEEK matrix is a potential solution to address the formation of a fibrous tissue layer between PEEK and bone and has not been tested. Using in vivo ovine animal models, we asked: (1) Does PEEK-HA improve cortical and cancellous bone ongrowth compared with PEEK? (2) Does PEEK-HA improve bone ongrowth and fusion outcome in a more challenging functional ovine cervical fusion model? The in vivo responses of PEEK-HA Enhanced and PEEK-OPTIMA ® Natural were evaluated for bone ongrowth in the form of dowels implanted in the cancellous and cortical bone of adult sheep and examined at 4 and 12 weeks as well as interbody cervical fusion at 6, 12, and 26 weeks. The bone-implant interface was evaluated with radiographic and histologic endpoints for a qualitative assessment of direct bone contact of an intervening fibrous tissue later. Gamma-irradiated cortical allograft cages were evaluated as well. Incorporating HA into the PEEK matrix resulted in more direct bone apposition as opposed to the fibrous tissue interface with PEEK alone in the bone ongrowth as well as interbody cervical fusions. No adverse reactions were found at the implant-bone interface for either material. Radiography and histology revealed resorption and fracture of the allograft devices in vivo. Incorporating HA into PEEK provides a more favorable environment than PEEK alone for bone ongrowth. Cervical fusion was improved with PEEK-HA compared with PEEK alone as well as allograft bone interbody devices. Improving the bone-implant interface with a PEEK device by incorporating HA may improve interbody fusion results and requires further clinical studies.

  5. Resorbable electrospun polydioxanone fibres modify the behaviour of cells from both healthy and diseased human tendons

    Directory of Open Access Journals (Sweden)

    A Kendal

    2017-02-01

    Full Text Available Chronic tendinopathy in an active and ageing population represents an increasing burden to healthcare systems. Rotator cuff tendinopathy alone accounts for approximately 70 % of all shoulder pain. Tendinopathic tissue has a disorganised extracellular matrix, altered vasculature, and infiltration of fibroblasts and inflammatory cells. This altered biology may contribute to the limited success of surgical repair strategies. Electrospun resorbable scaffolds can potentially enhance endogenous repair mechanisms by influencing the tissue microenvironment. Polydioxanone (PDO has an established safety profile in patients. We compared the response of healthy and diseased human tendon cells to electrospun PDO fibres using live cell imaging, proliferation, flow cytometry, and gene expression studies. Within 4 h of initial contact with electrospun PDO, healthy tendon cells underwent a marked transformation; elongating along the fibres in a fibre density dependent manner. Diseased tendon cells initially responded at a slower rate, but ultimately underwent a similar morphological change. Electrospun fibres increased the proliferation rate of diseased tendon cells and increased the ratio of type I:IIIcollagenmRNA expression. Flow cytometry revealed decreased expression of CD106, a marker of mesenchymal stem cells, and increased expression of CD10 on healthy versus diseased tendon cells. PDO electrospun scaffolds further promoted CD106negCD10pos expression of healthy tendon cells. Despite their behavioural differences, both healthy and diseased human tendon cells responded to electrospun PDO fibres. This encourages further work establishing their efficacy in augmenting surgical repair of diseased tendons.

  6. Reconstruction of long digital extensor tendon by cranial tibial muscle fascia graft in a dog.

    Science.gov (United States)

    Sabiza, Soroush; Khajeh, Ahmad; Naddaf, Hadi

    2016-01-01

    Tendon rupture in dogs is generally the result of a direct trauma. This report described the use of adjacent muscle autogenic fascial graft for reconstruction of distal rupture of long digital extensor tendon in a dog. A two-year-old male mix breed dog, was presented with a non-weight bearing lameness of the right hind limb and a deep rupture of lateral side of right tarsus. History taking revealed that this rupture appeared without any apparent cause, when walking around the farm, three days before. Radiography was done and no fracture was observed. Hyperextension of right tarsal joint compared to left limb was observed. Under general anesthesia, after dissections of the ruptured area, complete rupture of long digital extensor tendon was revealed. Then, we attempted to locate the edge of the tendon, however, the tendon length was shortened approximately 1 cm. Hence, a strip of 1 cm length from fascia of cranial tibial muscle was harvested to fill the defect. The graft was sutured to the two ends of tendon using locking loop pattern. Subcutaneous layers and the skin were sutured routinely. Ehmer sling bandage was applied to prevent weight bearing on the surgical region. Re-examination and phone contact with the owner eight weeks and six months postoperatively revealed a poor lameness and excellent function of the dog, respectively. It could be concluded that the fascia of adjacent muscles can be used as an autogenic graft for reconstruction of some tendon ruptures.

  7. Osteocalcin expressing cells from tendon sheaths in mice contribute to tendon repair by activating Hedgehog signaling

    OpenAIRE

    Wang, Yi; Zhang, Xu; Huang, Huihui; Xia, Yin; Yao, YiFei; Mak, Arthur Fuk-Tat; Yung, Patrick Shu-Hang; Chan, Kai-Ming; Wang, Li; Zhang, Chenglin; Huang, Yu; Mak, Kingston King-Lun

    2017-01-01

    Both extrinsic and intrinsic tissues contribute to tendon repair, but the origin and molecular functions of extrinsic tissues in tendon repair are not fully understood. Here we show that tendon sheath cells harbor stem/progenitor cell properties and contribute to tendon repair by activating Hedgehog signaling. We found that Osteocalcin (Bglap) can be used as an adult tendon-sheath-specific marker in mice. Lineage tracing experiments show that Bglap-expressing cells in adult sheath tissues pos...

  8. Bioreactor Design for Tendon/Ligament Engineering

    OpenAIRE

    Wang, Tao; Gardiner, Bruce S.; Lin, Zhen; Rubenson, Jonas; Kirk, Thomas B.; Wang, Allan; Xu, Jiake; Smith, David W.; Lloyd, David G.; Zheng, Ming H.

    2012-01-01

    Tendon and ligament injury is a worldwide health problem, but the treatment options remain limited. Tendon and ligament engineering might provide an alternative tissue source for the surgical replacement of injured tendon. A bioreactor provides a controllable environment enabling the systematic study of specific biological, biochemical, and biomechanical requirements to design and manufacture engineered tendon/ligament tissue. Furthermore, the tendon/ligament bioreactor system can provide a s...

  9. Magnetic resonance imaging appearance of the flexor carpi radialis tendon after harvest in ligamentous reconstruction tendon interposition arthroplasty

    International Nuclear Information System (INIS)

    Beall, Douglas P.; Fish, Jon R.; Ritchie, Eric R.; Tran, Hoang N.; Ingari, John V.; Campbell, Scot E.; Grayson, David E.; Sanders, Timothy G.; Mundis, Gregory; Lehman, Thomas P.

    2006-01-01

    To determine whether the post-harvest magnetic resonance (MR) imaging appearance of flexor carpi radialis (FCR) tendons, harvested during ligamentous reconstruction tendon interposition (LRTI) of the thumb carpometacarpal (CMC) joint arthroplasty, is consistent with tendon regeneration. Operative reports and patient medical records for all patients undergoing LRTI arthroplasty between 1995 and 2003 at our institution were reviewed. MR images of the patients' forearms and wrists were obtained and interpreted by two musculoskeletal radiologists. Using the flexor carpi ulnaris (FCU) tendon as an internal standard, the extent of FCR tendon regeneration was expressed as a percentage by dividing the volume of regenerated FCR tendon by the volume of the FCU tendon. Fourteen patients who had the full thickness of the FCR tendon harvested and who were available for MR imaging were identified and included in the study. At least partial regeneration of the FCR tendon occurred in 11 of the 14 patients (79%). Of these, 2 patients (14%), demonstrated complete, or nearly complete regeneration. Partial regeneration of the FCR tendon was seen in 9 of the 14 patients (64%). In 3 patients (21%), there was no appreciable regeneration of the FCR tendon. Among patients who underwent full-thickness harvest of the FCR tendon for LRTI arthroplasty of the first CMC joint, the follow-up MR imaging appearance of the flexor carpi radialis tendon was consistent with tendon regeneration in 79% of those examined. (orig.)

  10. Optimization of human tendon tissue engineering: peracetic acid oxidation for enhanced reseeding of acellularized intrasynovial tendon.

    Science.gov (United States)

    Woon, Colin Y L; Pridgen, Brian C; Kraus, Armin; Bari, Sina; Pham, Hung; Chang, James

    2011-03-01

    Tissue engineering of human flexor tendons combines tendon scaffolds with recipient cells to create complete cell-tendon constructs. Allogenic acellularized human flexor tendon has been shown to be a useful natural scaffold. However, there is difficulty repopulating acellularized tendon with recipient cells, as cell penetration is restricted by a tightly woven tendon matrix. The authors evaluated peracetic acid treatment in optimizing intratendinous cell penetration. Cadaveric human flexor tendons were harvested, acellularized, and divided into experimental groups. These groups were treated with peracetic acid in varying concentrations (2%, 5%, and 10%) and for varying time periods (4 and 20 hours) to determine the optimal treatment protocol. Experimental tendons were analyzed for differences in tendon microarchitecture. Additional specimens were reseeded by incubation in a fibroblast cell suspension at 1 × 10(6) cells/ml. This group was then analyzed for reseeding efficacy. A final group underwent biomechanical studies for strength. The optimal treatment protocol comprising peracetic acid at 5% concentration for 4 hours produced increased scaffold porosity, improving cell penetration and migration. Treated scaffolds did not show reduced collagen or glycosaminoglycan content compared with controls (p = 0.37 and p = 0.65, respectively). Treated scaffolds were cytotoxic to neither attached cells nor the surrounding cell suspension. Treated scaffolds also did not show inferior ultimate tensile stress or elastic modulus compared with controls (p = 0.26 and p = 0.28, respectively). Peracetic acid treatment of acellularized tendon scaffolds increases matrix porosity, leading to greater reseeding. It may prove to be an important step in tissue engineering of human flexor tendon using natural scaffolds.

  11. Diagnostic value of US, CT arthrography, and 0.5-T MR imaging of lesions of the biceps tendon

    International Nuclear Information System (INIS)

    Saez, F.; Elizagaray, E.; Pena, J.M.; Ferrero, A.; Azkuna, I.; Larrea, L.

    1990-01-01

    This paper evaluates the role of US, CT-arthrography, and MR imaging in lesions in the tendon of the long head of the biceps brachii and bicipital groove. One hundred fifty-four patients with painful shoulder were prospectively studied by means of US and axial CT-arthrography, and 45 of them were also examined with 0.5-T MR imaging. Fifty-three (34.4%) patients showed biceps tendon or bicipital groove abnormalities; including 34 bicipital groove bone spurs, 31 cases of tendinitis, eight intraarticular ruptures, four subluxations, and eight medial dislocations

  12. Development of a 3-D x-ray micro-tomography system and its application to trabecular bone/cement interface

    International Nuclear Information System (INIS)

    Chi, Yong Ki; Cho, Gyuseong

    2004-01-01

    In recent years, the interface analysis of micro-structure based objects is an important research in osteoporosis, vascular imaging since a 3-D X-ray micro-tomography system was developed. However, the micro-tomographic image shows the white-out appearance in case of imaging of similar density objects with low energy X-ray. Therefore these images must be analyzed about the interface between microstructure based objects for its application to biomechanical study. Many published studies suggested approximately assumed model of interface and predicted mechanical failure by means of Finite Element Method (FEM) but these FEM analysis has not used for modeling the real structure and interface between objects such as roughness, voids and pores of objects. We developed micro-tomography system and suggest the application of micro-tomographic image for predicting mechanical failure at the interface. The micro-tomography system consists of a 5 μm micro-focus X-ray tube, a CMOS-based image sensor and a rotating sample holder controlled by a precision motor. CMOS image sensor has 62x62 mm 2 sensing area and uses optical lenses system for increasing resolution. The sample which was manufactured by implanting cement in a pig hip bone was used and its fracture is considered to be an important cause of loosening of hip joint replacement in orthopedic implants. A Feldkamp's cone-beam reconstruction algorithm on the equispatial detector case was used for bone/cement 3D volume data and the analysis of a trabecular bone/cement interface containing white-out appearance was performed by using multiple criterion segmentation of region and volume. Finally, the segmented data can be used for fracture prediction of FEM by determining node of hexahedron meshing. In this paper, we present development of a 3-D cone beam micro-tomographic system with CMOS image sensor and its application to a complex structure of a trabecular bone and implanted cement for predicting the failure mechanism of

  13. Effect of interfaces on electron transport properties of MoS2-Au Contacts

    Science.gov (United States)

    Aminpour, Maral; Hapala, Prokop; Le, Duy; Jelinek, Pavel; Rahman, Talat S.; Rahman's Group Collaboration; Nanosurf Lab Collaboration

    2014-03-01

    Single layer MoS2 is a promising material for future electronic devices such as transistors since it has good transport characteristics with mobility greater than 200 cm-1V-1s-1 and on-off current ratios up to 108. However, before MoS2 can become a mainstream electronic material for the semiconductor industry, the design of low resistive metal-semiconductor junctions as contacts of the electronic devices needs to be addressed and studied systematically. We have examined the effect of Au contacts on the electronic transport properties of single layer MoS2 using density functional theory in combination with the non-equilibrium Green's function method. The Schottky barrier between Au contact and MoS2, transmission spectra, and I-V curves will be reported and discussed as a function of MoS2 and Au interfaces of varying geometry. This work is supported in part by the US Department of Energy under grant DE-FG02-07ER15842.

  14. Relationship between the real contact area and contact force in pre-sliding regime

    International Nuclear Information System (INIS)

    Song Baojiang; Yan Shaoze

    2017-01-01

    The pre-sliding regime is typically neglected in the dynamic modelling of mechanical systems. However, the change in contact state caused by static friction may decrease positional accuracy and control precision. To investigate the relationship between contact status and contact force in pre-sliding friction, an optical experimental method is presented in this paper. With this method, the real contact state at the interface of a transparent material can be observed based on the total reflection principle of light by using an image processing technique. A novel setup, which includes a pair of rectangular trapezoidal blocks, is proposed to solve the challenging issue of accurately applying different tangential and normal forces to the contact interface. The improved Otsu’s method is used for measurement. Through an experimental study performed on polymethyl methacrylate (PMMA), the quantity of contact asperities is proven to be the dominant factor that affects the real contact area. The relationship between the real contact area and the contact force in the pre-sliding regime is studied, and the distribution of static friction at the contact interface is qualitatively discussed. New phenomena in which the real contact area expands along with increasing static friction are identified. The aforementioned relationship is approximately linear at the contact interface under a constant normal pressure, and the distribution of friction stress decreases from the leading edge to the trailing edge. (paper)

  15. Achilles Tendon's Tear

    OpenAIRE

    F. Shahandeh

    2008-01-01

    Introduction: The achilles and plantaris tendons to-gether makeup the posterior grouptendons of ankle. Their seldom confusion in interpreting MR images of the achilles tendon. The achilles tendon should ap-pear informally straight and black on sagital T1 weighted images and on fluid sensitive images."nCase Presentation: After a heavy sport, a 55 year-old woman cannot walk with right foot."nDiscussion: The classic achilles tendon rupture occurs with forced dorsiflexion of planted foo...

  16. Bioreactor design for tendon/ligament engineering.

    Science.gov (United States)

    Wang, Tao; Gardiner, Bruce S; Lin, Zhen; Rubenson, Jonas; Kirk, Thomas B; Wang, Allan; Xu, Jiake; Smith, David W; Lloyd, David G; Zheng, Ming H

    2013-04-01

    Tendon and ligament injury is a worldwide health problem, but the treatment options remain limited. Tendon and ligament engineering might provide an alternative tissue source for the surgical replacement of injured tendon. A bioreactor provides a controllable environment enabling the systematic study of specific biological, biochemical, and biomechanical requirements to design and manufacture engineered tendon/ligament tissue. Furthermore, the tendon/ligament bioreactor system can provide a suitable culture environment, which mimics the dynamics of the in vivo environment for tendon/ligament maturation. For clinical settings, bioreactors also have the advantages of less-contamination risk, high reproducibility of cell propagation by minimizing manual operation, and a consistent end product. In this review, we identify the key components, design preferences, and criteria that are required for the development of an ideal bioreactor for engineering tendons and ligaments.

  17. Experimental and Computational Investigation of Viscoelasticity of Native and Engineered Ligament and Tendon

    Science.gov (United States)

    Ma, J.; Narayanan, H.; Garikipati, K.; Grosh, K.; Arruda, E. M.

    The important mechanisms by which soft collagenous tissues such as ligament and tendon respond to mechanical deformation include non-linear elasticity, viscoelasticity and poroelasticity. These contributions to the mechanical response are modulated by the content and morphology of structural proteins such as type I collagen and elastin, other molecules such as glycosaminoglycans, and fluid. Our ligament and tendon constructs, engineered from either primary cells or bone marrow stromal cells and their autogenous matricies, exhibit histological and mechanical characteristics of native tissues of different levels of maturity. In order to establish whether the constructs have optimal mechanical function for implantation and utility for regenerative medicine, constitutive relationships for the constructs and native tissues at different developmental levels must be established. A micromechanical model incorporating viscoelastic collagen and non-linear elastic elastin is used to describe the non-linear viscoelastic response of our homogeneous engineered constructs in vitro. This model is incorporated within a finite element framework to examine the heterogeneity of the mechanical responses of native ligament and tendon.

  18. [Reconstruction of the extensor pollicis longus tendon by transposition of the extensor indicis tendon].

    Science.gov (United States)

    Loos, A; Kalb, K; Van Schoonhoven, J; Landsleitner Dagger, B

    2003-12-01

    Rupture of the extensor pollicis longus-tendon (EPL) is a frequent complication after distal radius fractures. Other traumatic and non-traumatic reasons for this tendon lesion are known, including a theory about a disorder in the blood supply to the tendon itself. We examined 40 patients after reconstruction of the EPL-tendon in a mean follow-up time of 30 months. All patients were clinically examined and a DASH questionnaire was answered by all patients. The method to reconstruct the EPL-tendon was the transposition of the extensor indicis-tendon. After the operations the thumb was put in a splint for four weeks in a "hitch-hiker's-position". 31 ruptures of the tendon (77.5 %) were a result of trauma. In 20 of them (50 %) a distal radius fracture had occurred. Clinical examination included measurements of the movement of the thumb- and index-finger joints, the grip strength and the maximal span of the hand. Significant differences were not found. The isolated extension of the index finger was possible in all patients. But it was reduced in ten cases which represent 25 %. Our results were evaluated by the Geldmacher score to evaluate the reconstruction of the EPL-tendon. 20 % excellent, 65 % good, 12.5 % fair and 2.5 % poor results were reached. The Geldmacher score was used critically. We suggest its modification for the evaluation of thumb abduction. The DASH score reached a functional value of ten points which represents a very good result. In conclusion the extensor indicis-transposition is a safe method to reconstruct the EPL-tendon. Its substantial advantage is taking a healthy muscle as the motor, thereby avoiding the risk of using a degenerated muscle in late tendon reconstruction. A powerful extension of the index finger will be maintained by physical education. Generally, the loss of the extension of the index finger is negligible. It does not disturb the patients. But it has to be discussed with the patient before the operation.

  19. Optimal arm posture control and tendon traction forces of a coupled tendon-driven manipulator

    International Nuclear Information System (INIS)

    Ma, Shugen

    1997-01-01

    In this study, the optimum arm posture of a coupled tendon-driven multijoint manipulator arm (or CT Arm) at maximum payload output was derived and the corresponding tendon traction forces were also analyzed, during management of a heavy payload by the manipulator in a gravity environment. The CT Arm is special tendon traction transmission mechanism in which a pair of tendons used to drive a joint is pulled from base actuators via pulleys mounted on the base-side joints. This mechanism enables optimal utilization of the coupled drive function of tendon traction forces and thus enables the lightweight manipulator to exhibit large payload capability. The properties of the CT Arm mechanism are elucidated by the proposed optimal posture control scheme. Computer simulation was also executed to verify the validity of the proposed control scheme. (author)

  20. The Effect of Sodium Hyaluronate on Ligamentation and Biomechanical Property of Tendon in Repair of Achilles Tendon Defect with Polyethylene Terephthalate Artificial Ligament: A Rabbit Tendon Repair Model

    OpenAIRE

    Li, Shengkun; Ma, Kui; Li, Hong; Jiang, Jia; Chen, Shiyi

    2016-01-01

    The Achilles tendon is the most common ruptured tendon of human body. Reconstruction with polyethylene terephthalate (PET) artificial ligament is recommended in some serious cases. Sodium hyaluronate (HA) is beneficial for the healing of tendon injuries. We aimed to determine the effect of sodium hyaluronate in repair of Achilles tendon defect with PET artificial ligament in an animal tendon repair model. Sixteen New Zealand White rabbits were divided into two groups. Eight rabbits repaired w...

  1. High-field MR imaging of the tendons

    International Nuclear Information System (INIS)

    Beltran, J.; Burk, J.M.; Herman, L.J.; Mosure, J.C.

    1987-01-01

    MR imaging was used to investigate normal anatomy and pathologic conditions of the tendons. Tendons of experimental animals, cadaver joints, normal volunteers, and patients with suspected tendon pathology were studied. Tendon anatomy is easily identified because of the hypointensity of the tendons contrasting with the hyperintendensity of the surrounding fat. Pathologic conditions including posttraumatic and postsurgical tendon rupture, peritendinous scarring, tendinitis, and tenosynovitis are well seen with MR imaging. A detailed study of normal and abnormal tendon anatomy of the finger, wrist, shoulder, knee, and ankle is displayed, including MR images, gross specimens, and line drawings

  2. Clinical aspects of tendon healing

    NARCIS (Netherlands)

    J.C.H.M. van der Meulen (Jacques)

    1974-01-01

    textabstractWe know that healing of a tendon wound takes place by an invasion of fibreblasts from the surrounding tissues; the tendon itself has no intrinsic healing capacity. lt was Potenza (1962) who proved that a traumatic suture of the tendons within their sheath is followed by disintegration of

  3. A Rare Case of Simultaneous Acute Bilateral Quadriceps Tendon Rupture and Unilateral Achilles Tendon Rupture

    Directory of Open Access Journals (Sweden)

    Wei Yee Leong

    2013-07-01

    Full Text Available Introduction: There have been multiple reported cases of bilateral quadriceps tendon ruptures (QTR in the literature. These injuries frequently associated with delayed diagnosis, which results in delayed surgical treatment. In very unusual cases, bilateral QTRs can be associated with other simultaneous tendon ruptures. Case Report: We present a rare case of bilateral QTR with a simultaneous Achilles Tendon Rupture involving a 31 years old Caucasian man who is a semi-professional body builder taking anabolic steroids. To date bilateral QTR with additional TA rupture has only been reported once in the literature and to our knowledge this is the first reported case of bilateral QTR and simultaneous TA rupture in a young, fit and healthy individual. Conclusion: The diagnosis of bilateral QTR alone can sometimes be challenging and the possibility of even further tendon injuries should be carefully assessed. A delay in diagnosis could result in delay in treatment and potentially worse outcome for the patient. Keywords: Quadriceps tendon rupture; Achilles tendon rupture; Bilateral.

  4. Achilles tendon healing

    International Nuclear Information System (INIS)

    Dillon, E.H.; Pope, C.F.; Barber, V.; Jokl, P.; Lynch, K.

    1990-01-01

    This paper reports on symptomatic Achilles tendon abnormalities (rupture, tendinitis) evaluated with MR imaging during the healing phase after either surgical or conservative treatment. A total of 21 patients were studied. Fifteen of 21 underwent surgery (13 tendon ruptures) and six were managed conservatively (one rupture). MR studies were obtained before treatment in 11, at 3 months in eight, at 6 months in seven, and at 12 months in 12. The 1.5-T spin-echo and gradient-echo images were correlated with clinical results, planter reflex response times, and calf force measurements. Sequential T2 times were obtained from representative levels in the tendons

  5. Is There an Inherent Risk to Damage the Popliteus Tendon by Femoral Component With Inbuilt External Rotation? A Pilot Study in Indian Knees.

    Science.gov (United States)

    Chouhan, Dervendra Kumar; Dhillon, Mandeep S

    2016-02-01

    Femoral components with inbuilt rotation require thicker flexion resection of the lateral femoral condyle and could have a potential risk of damaging the popliteus tendon, especially in the smaller Asian knees. We prospectively evaluated 10 patients with bilateral varus osteoarthritis knee to size the cuts and their location in relation to the popliteus tendon. Two different types of implant were used on either side; one side requires resection in 3° external rotation (group A) and the other side requires a femoral component with inbuilt external rotation (group B). We observed the incidence of injury to the popliteus tendon and distance between flexion cut to its attachment over the lateral femoral condyle between both groups. We had popliteus tendon injury in 3 knees all from group B. Risk of damaging the popliteus tendon was found higher in group B, as the distance between flexion cut to popliteus tendon attachment was significantly low. Femoral component with inbuilt external rotation has more risk of injuring the popliteus tendon because flexion cut takes out more bone from the lateral femoral condyle. Copyright © 2015 Elsevier Inc. All rights reserved.

  6. Arthroscopic Release of Flexor Hallucis Longus Tendon Sheath in Female Ballet Dancers: Dynamic Pathology, Surgical Technique, and Return to Dancing Performance.

    Science.gov (United States)

    Funasaki, Hiroki; Hayashi, Hiroteru; Sakamoto, Kanako; Tsuruga, Rei; Marumo, Keishi

    2015-12-01

    Stenosing tenosynovitis of the flexor hallucis longus (FHL) tendon is known as a major overuse lesion in female dancers. We describe arthroscopic surgical techniques in relation to the dynamic pathology of the disease. Crepitus and pain on moving the great toe with the ankle in plantar flexion on preoperative examination confirm the diagnosis of FHL stenosing tenosynovitis even if the os trigonum is not evident. The ankle is approached through standard posterolateral and posteromedial portals. A 4.0-mm-diameter 30° arthroscope is used. Soft tissues around the talus are cleared with a motorized shaver and a radiofrequency device. The posterior aspects of the talus, os trigonum, and FHL tendon surrounded by the tendon sheath are visualized. The dynamic pathology of the FHL tendon is well observed on passive motion of the great toe. The prominent bone fragment of the talus is removed and the tendon sheath is cut with a retrograde knife and a motorized shaver from the superior border down to the entrance of the fibro-osseous tunnel. Arthroscopic release of the FHL tendon sheath is a useful and easy method to directly approach the dynamic pathology of FHL tenosynovitis in female ballet dancers.

  7. The Effect of Phospholipids (Surfactant on Adhesion and Biomechanical Properties of Tendon: A Rat Achilles Tendon Repair Model

    Directory of Open Access Journals (Sweden)

    T. Kursat Dabak

    2015-01-01

    Full Text Available Adhesion of the tendon is a major challenge for the orthopedic surgeon during tendon repair. Manipulation of biological environment is one of the concepts to prevent adhesion. Lots of biochemicals have been studied for this purpose. We aimed to determine the effect of phospholipids on adhesion and biomechanical properties of tendon in an animal tendon repair model. Seventy-two Wistar rats were divided into 4 groups. Achilles tendons of rats were cut and repaired. Phospholipids were applied at two different dosages. Tendon adhesion was determined histopathologically and biomechanical test was performed. At macroscopic evaluation of adhesion, there are statistically significant differences between multiple-dose phospholipid injection group and Control group and also hyaluronic acid group and Control group (p0.008. Ultimate strength was highest at hyaluronic acid injection group and lowest at multiple-dose phospholipid injection group. Single-dose phospholipids (surfactant application may have a beneficial effect on the tendon adhesion. Although multiple applications of phospholipids seem the most effective regime to reduce the tendon adhesion among groups, it deteriorated the biomechanical properties of tendon.

  8. MRI findings of achilles tendon rupture

    International Nuclear Information System (INIS)

    Zhang Xuezhe

    2009-01-01

    Objective: To evaluate the MRI findings of achilles tendon rupture. Methods: The MRI data of 7 patients with achilles tendon rupture were retrospectively analysed. All 7 patients were male with the age ranging from 34 to 71 years. Routine MR scanning was performed in axial and sagittal planes, including T 1 WI, T 2 WI and a fat suppression MRI (SPIR). Results: Among 7 patients, complete achilles tendon rupture was seen in 6 cases, partial achilles tendon rupture 1 case. The site of tendon disruption were 2.6-11.0 cm( mean 5.4 cm) proximal to the insertion in the calcaneus. The MRI findings of a partial or complete rupture of the achilles tendon included enlarged and thickened achilles tendon (7 cases), wavy lax achilles tendon (2 cases), discontinuity of some or all of its fibers and intratendinous regions of increased signal intensity (7 cases). In the cases of complete tendon rupture, the size of the tendinous gap varied from 3.0-8.0 mm, which was filled with blood and appeared as edema of increase signal intensity on T 2 WI and SPIR. In all 7 patients, MR scanning showed medium signal intensity (7 cases) on T 1 WI, or medium signal intensity (1 cases), medium-high signal intensity (3 cases ), high signal intensity (3 cases) on T 2 WI, and medium-high signal intensity (2 cases), high signal intensity (5 cases) on fat suppression MRI. The preachilles fat pad showed obscure in 6 cases of complete achilles tendon rupture. Conclusion: MRI is an excellent method for revealing achilles tendon rupture and confirming the diagnosis. (authors)

  9. Can PRP effectively treat injured tendons?

    Science.gov (United States)

    Wang, James H-C

    2014-01-01

    PRP is widely used to treat tendon and other tissue injuries in orthopaedics and sports medicine; however, the efficacy of PRP treatment on injured tendons is highly controversial. In this commentary, I reason that there are many PRP- and patient-related factors that influence the outcomes of PRP treatment on injured tendons. Therefore, more basic science studies are needed to understand the mechanism of PRP on injured tendons. Finally, I suggest that better understanding of the PRP action mechanism will lead to better use of PRP for the effective treatment of tendon injuries in clinics.

  10. MRI of anterior cruciate ligament repair with patellar and hamstring tendon autografts

    International Nuclear Information System (INIS)

    Jansson, K.A.; Karjalainen, P.T.; Harilainen, A.; Sandelin, J.; Tallroth, K.; Soila, K.; Aronen, H.J.

    2001-01-01

    Objective. Several MRI sequences were used to evaluate the 2-year postoperative appearance of asymptomatic knee with a torn anterior cruciate ligament (ACL) reconstructed with bone-patellar tendon-bone (BTB) and semitendinosus and gracilis (STG) tendon autografts.Design and patients. Two groups with successful repair of ACL tear with BTB (n=10) or STG (n=10) autografts were imaged at 1.5 T with sagittal and oblique coronal proton density-, T2-weighted and sagittal STIR sequences and plain and contrast-enhanced oblique coronal T1-weighted sequences. The appearance of the graft and periligamentous tissues was evaluated.Results. In all 20 cases, the ACL graft showed homogeneous, low signal intensity with periligamentous streaks of intermediate signal intensity on T2-weighted images. In 10 cases, localised areas of intermediate signal intensity were seen in the intra-articular segment of the graft on proton density- and T1-weighted images. The graft itself did not show enhancement in either of the two groups, but mild to moderate periligamentous enhancement was detected in 10 cases.Conclusion. The MRI appearance of ACL autograft is variable on proton density- and T1-weighted images. Periligamentous tissue showing contrast enhancement is a typical MRI finding after clinically successful ACL reconstruction. (orig.)

  11. Measuring Regional Changes in Damaged Tendon

    Science.gov (United States)

    Frisch, Catherine Kayt Vincent

    Mechanical properties of tendon predict tendon health and function, but measuring these properties in vivo is difficult. An ultrasound-based (US) analysis technique called acoustoelastography (AE) uses load-dependent changes in the reflected US signal to estimate tissue stiffness non-invasively. This thesis explores whether AE can provide information about stiffness alteration resulting from tendon tears both ex vivo and in vivo. An ex vivo ovine infraspinatus tendon model suggests that the relative load transmitted by the different tendon layers transmit different fractions of the load and that ultrasound echo intensity change during cyclic loading decreases, becoming less consistent once the tendon is torn. An in vivo human tibialis anterior tendon model using electrically stimulated twitch contractions investigated the feasibility of measuring the effect in vivo. Four of the five subjects showed the expected change and that the muscle contraction times calculated using the average grayscale echo intensity change compared favorably with the times calculated based on the force data. Finally an AE pilot study with patients who had rotator cuff tendon tears found that controlling the applied load and the US view of the system will be crucial to a successful in vivo study.

  12. Tendon sheath fibroma in the thigh.

    Science.gov (United States)

    Moretti, Vincent M; Ashana, Adedayo O; de la Cruz, Michael; Lackman, Richard D

    2012-04-01

    Tendon sheath fibromas are rare, benign soft tissue tumors that are predominantly found in the fingers, hands, and wrists of young adult men. This article describes a tendon sheath fibroma that developed in the thigh of a 70-year-old man, the only known tendon sheath fibroma to form in this location. Similar to tendon sheath fibromas that develop elsewhere, our patient's lesion presented as a painless, slow-growing soft tissue nodule. Physical examination revealed a firm, nontender mass with no other associated signs or symptoms. Although the imaging appearance of tendon sheath fibromas varies, our patient's lesion appeared dark on T1- and bright on T2-weighted magnetic resonance imaging. It was well marginated and enhanced with contrast.Histologically, tendon sheath fibromas are composed of dense fibrocollagenous stromas with scattered spindle-shaped fibroblasts and narrow slit-like vascular spaces. Most tendon sheath fibromas can be successfully removed by marginal excision, although 24% of lesions recur. No lesions have metastasized. Our patient's tendon sheath fibroma was removed by marginal excision, and the patient remained disease free 35 months postoperatively. Despite its rarity, tendon sheath fibroma should be included in the differential diagnosis of a thigh mass on physical examination or imaging, especially if it is painless, nontender, benign appearing, and present in men. Copyright 2012, SLACK Incorporated.

  13. Tissue engineering approaches to develop decellularized tendon matrices functionalized with progenitor cells cultured under undifferentiated and tenogenic conditions

    Directory of Open Access Journals (Sweden)

    Daniele D’Arrigo

    2017-11-01

    Full Text Available Tendon ruptures and retractions with an extensive tissue loss represent a major clinical problem and a great challenge in surgical reconstruction. Traditional approaches consist in autologous or allogeneic grafts, which still have some drawbacks. Hence, tissue engineering strategies aimed at developing functionalized tendon grafts. In this context, the use of xenogeneic tissues represents a promising perspective to obtain decellularized tendon grafts. This study is focused on the identification of suitable culture conditions for the generation of reseeded and functional decellularized constructs to be used as tendon grafts. Equine superficial digital flexor tendons were decellularized, reseeded with mesenchymal stem cells (MSCs from bone marrow and statically cultured in two different culture media to maintain undifferentiated cells (U-MSCs or to induce a terminal tenogenic differentiation (T-MSCs for 24 hours, 7 and 14 days. Cell viability, proliferation, morphology as well as matrix deposition and type I and III collagen production were assessed by means of histological, immunohistochemical and semi-quantitative analyses. Results showed that cell viability was not affected by any culture conditions and active proliferation was maintained 14 days after reseeding. However, seeded MSCs were not able to penetrate within the dense matrix of the decellularized tendons. Nevertheless, U-MSCs synthesized a greater amount of extracellular matrix rich in type I collagen compared to T-MSCs. In spite of the inability to deeply colonize the decellularized matrix in vitro, reseeding tendon matrices with U-MSCs could represent a suitable method for the functionalization of biological constructs, considering also any potential chemoattractant capability of the newly deposed extracellular matrix to recruit resident cells. This bioengineering approach can be exploited to produce functionalized tendon constructs for the substitution of large tendon defects.

  14. Quadriceps Tendon Rupture and Contralateral Patella Tendon Avulsion Post Primary Bilateral Total Knee Arthroplasty: A Case Report

    Directory of Open Access Journals (Sweden)

    Gaurav Sharma

    2016-07-01

    Full Text Available Background: Extensor mechanism failure secondary to knee replacement could be due to tibial tubercle avulsion, Patellar tendon rupture, patellar fracture or quadriceps tendon rupture. An incidence of Patella tendon rupture of 0.17% and Quadriceps tendon rupture of around 0.1% has been reported after Total knee arthroplasty. These are considered a devastating complication that substantially affects the clinical results and are challenging situations to treat with surgery being the mainstay of the treatment. Case Description: We report here an interesting case of a patellar tendon rupture of one knee and Quadriceps tendon rupture of the contralateral knee following simultaneous bilateral knee replacement in a case of inflammatory arthritis patient. End to end repair for Quadriceps tear and augmentation with Autologous Hamstring tendon graft was done for Patella tendon rupture. OUTCOME: Patient was followed up for a period of 1 year and there was no Extension lag with a flexion of 100 degrees in both the knees. DISCUSSION: The key learning points and important aspects of diagnosing these injuries early and the management techniques are described in this unique case of bilateral extensor mechanism disruption following knee replacements.

  15. Ectopic mineralization of cartilage and collagen-rich tendons and ligaments in Enpp1asj-2J mice.

    Science.gov (United States)

    Zhang, Jieyu; Dyment, Nathaniel A; Rowe, David W; Siu, Sarah Y; Sundberg, John P; Uitto, Jouni; Li, Qiaoli

    2016-03-15

    Generalized arterial calcification of infancy (GACI), an autosomal recessive disorder caused by mutations in the ENPP1 gene, manifests with extensive mineralization of the cardiovascular system. A spontaneous asj-2J mutant mouse has been characterized as a model for GACI. Previous studies focused on phenotypic characterization of skin and vascular tissues. This study further examined the ectopic mineralization phenotype of cartilage, collagen-rich tendons and ligaments in this mouse model. The mice were placed on either control diet or the "acceleration diet" for up to 12 weeks of age. Soft connective tissues, such as ear (elastic cartilage) and trachea (hyaline cartilage), were processed for standard histology. Assessment of ectopic mineralization in articular cartilage and fibrocartilage as well as tendons and ligaments which are attached to long bones were performed using a novel cryo-histological method without decalcification. These analyses demonstrated ectopic mineralization in cartilages as well as tendons and ligaments in the homozygous asj-2J mice at 12 weeks of age, with the presence of immature osteophytes displaying alkaline phosphatase and tartrate-resistant acid phosphatase activities as early as at 6 weeks of age. Alkaline phosphatase activity was significantly increased in asj-2J mouse serum as compared to wild type mice, indicating increased bone formation rate in these mice. Together, these data highlight the key role of ENPP1 in regulating calcification of both soft and skeletal tissues.

  16. Weft-knitted silk-poly(lactide-co-glycolide) mesh scaffold combined with collagen matrix and seeded with mesenchymal stem cells for rabbit Achilles tendon repair.

    Science.gov (United States)

    Zhang, Wenyuan; Yang, Yadong; Zhang, Keji; Li, Ying; Fang, Guojian

    2015-02-01

    Natural silk fibroin fiber scaffolds have excellent mechanical properties, but degrade slowly. In this study, we used poly(lactide-co-glycolide) (PLGA, 10:90) fibers to adjust the overall degradation rate of the scaffolds and filled them with collagen to reserve space for cell growth. Silk fibroin-PLGA (36:64) mesh scaffolds were prepared using weft-knitting, filled with type I collagen, and incubated with rabbit autologous bone marrow-derived mesenchymal stem cells (MSCs). These scaffold-cells composites were implanted into rabbit Achilles tendon defects. At 16 weeks after implantation, morphological and histological observations showed formation of tendon-like tissues that expressed type I collagen mRNA and a uniformly dense distribution of collagen fibers. The maximum load of the regenerated Achilles tendon was 58.32% of normal Achilles tendon, which was significantly higher than control group without MSCs. These findings suggest that it is feasible to construct tissue engineered tendon using weft-knitted silk fibroin-PLGA fiber mesh/collagen matrix seeded with MSCs for rabbit Achilles tendon defect repair.

  17. Role of tissue-engineered artificial tendon in healing of a large Achilles tendon defect model in rabbits.

    Science.gov (United States)

    Moshiri, Ali; Oryan, Ahmad; Meimandi-Parizi, Abdolhamid

    2013-09-01

    Treatment of large Achilles tendon defects is technically demanding. Tissue engineering is an option. We constructed a collagen-based artificial tendon, covered it with a polydioxanon (PDS) sheath, and studied the role of this bioimplant on experimental tendon healing in vivo. A 2-cm tendon gap was created in the left Achilles tendon of rabbits (n = 120). The animals were randomly divided into 3 groups: control (no implant), treated with tridimensional-collagen, and treated with tridimensional-collagen-bidimensional-PDS implants. Each group was divided into 2 subgroups of 60 and 120 days postinjury (DPI). Another 50 pilot animals were used to study the host-implant interaction. Physical activity of the animals was scored and ultrasonographic and bioelectrical characteristics of the injured tendons were investigated weekly. After euthanasia, macro, micro, and nano morphologies and biophysical and biomechanical characteristics of the healing tendons were studied. Treatment improved function of the animals, time dependently. At 60 and 120 DPI, the treated tendons showed significantly higher maximum load, yield, stiffness, stress, and modulus of elasticity compared with controls. The collagen implant induced inflammation and absorbed the migrating fibroblasts in the defect area. By its unique architecture, it aligned the fibroblasts and guided their proliferation and collagen deposition along the stress line of the tendon and resulted in improved collagen density, micro-amp, micro-ohm, water uptake, and delivery of the regenerated tissue. The PDS-sheath covering amplified these characteristics. The implants were gradually absorbed and replaced by a new tendon. Minimum amounts of peritendinous adhesion, muscle atrophy, and fibrosis were observed in the treated groups. Some remnants of the implants were preserved and accepted as a part of the new tendon. The implants were cytocompatible, biocompatible, biodegradable, and effective in tendon healing and regeneration. This

  18. Microstructural stress relaxation mechanics in functionally different tendons.

    Science.gov (United States)

    Screen, H R C; Toorani, S; Shelton, J C

    2013-01-01

    Tendons experience widely varying loading conditions in vivo. They may be categorised by their function as either positional tendons, which are used for intricate movements and experience lower stress, or as energy storage tendons which act as highly stressed springs during locomotion. Structural and compositional differences between tendons are thought to enable an optimisation of their properties to suit their functional environment. However, little is known about structure-function relationships in tendon. This study adopts porcine flexor and extensor tendon fascicles as examples of high stress and low stress tendons, comparing their mechanical behaviour at the micro-level in order to understand their stress relaxation response. Stress-relaxation was shown to occur predominantly through sliding between collagen fibres. However, in the more highly stressed flexor tendon fascicles, more fibre reorganisation was evident when the tissue was exposed to low strains. By contrast, the low load extensor tendon fascicles appears to have less capacity for fibre reorganisation or shearing than the energy storage tendon, relying more heavily on fibril level relaxation. The extensor fascicles were also unable to sustain loads without rapid and complete stress relaxation. These findings highlight the need to optimise tendon repair solutions for specific tendons, and match tendon properties when using grafts in tendon repairs. Copyright © 2012 IPEM. Published by Elsevier Ltd. All rights reserved.

  19. A Unique Method to Describe the Bonding Strength in a Bonded Solid–Solid Interface by Contact Acoustic Nonlinearity

    International Nuclear Information System (INIS)

    Jian-Jun, Chen; De, Zhang; Yi-Wei, Mao; Jian-Chun, Cheng

    2009-01-01

    We present a unique method to describe the bonding strength at a bonded solid–solid interface in a multilayered composite material by contact acoustic nonlinearity (CAN) parameter. A CAN model on the bonded solid–solid interface is depicted. It can be seen from the model that CAN parameter is very sensitive to the bonding strength at the interface. When an incident focusing acoustic longitudinal wave scans the interface in two dimensions, the transmitted wave can be used to extract CAN parameter. The contour of the bonding strength for a sample is obtained by CAN parameter. The results show that the region with weak bonding strength can be easily distinguished from the contour

  20. The roentgenographic findings of achilles tendon rupture

    Energy Technology Data Exchange (ETDEWEB)

    Seouk, Kang Hyo; Keun, Rho Yong [Shilla General Hospital, Seoul (Korea, Republic of)

    1999-03-01

    To evaluate the diagnostic value of a lateral view of the ankles in Achilles tendon rupture. We performed a retrospective analysis of the roentgenographic findings of 15 patients with surgically proven Achilles tendon rupture. Four groups of 15 patients(normal, ankle sprain, medial lateral malleolar fracture, and calcaneal fracture) were analysed as reference groups. Plain radiographs were reviewed with regard to Kager's triangle, Arner's sign, Toygar's angle, ill defined radiolucent shadow through the Achilles tendon, sharpness of the anterior margin of Achilles tendon, and meniscoid smooth margin of the posterior skin surface of the ankle. Kager's triangle was deformed and disappeared after rupture of the Achilles tendon in nine patients(60%) with operative verification of the rupture, six patients(40%) had a positive Arner's sign, while none had a diminished Toygars angle. In 13 patients(87%) with a ruptured Achilles tendon, the thickness of this was nonuniform compared with the reference group. The anterior margin of the Achilles tendon became serrated and indistinct in 14 patients(93%) in whom this was ruptured. An abnormal ill defined radiolucent shadow through the Achilles tendon was noted in nine patient(60%), and nonparallelism between the anterior margin of the Achilles tendon and posterior skin surface of the ankle was detected in 11 patients(73%). The posterior skin surface of the ankle had a nodular surface margin in 13 patients(87%). A deformed Kager's triangle and Achilles tendon, and an abnormal ill defined radiolucent shadow through the Achilles tendon in a lateral view of the ankles are important findings for the diagnesis of in diagnosing achilles tendon rupture.

  1. The roentgenographic findings of achilles tendon rupture

    International Nuclear Information System (INIS)

    Seouk, Kang Hyo; Keun, Rho Yong

    1999-01-01

    To evaluate the diagnostic value of a lateral view of the ankles in Achilles tendon rupture. We performed a retrospective analysis of the roentgenographic findings of 15 patients with surgically proven Achilles tendon rupture. Four groups of 15 patients(normal, ankle sprain, medial lateral malleolar fracture, and calcaneal fracture) were analysed as reference groups. Plain radiographs were reviewed with regard to Kager's triangle, Arner's sign, Toygar's angle, ill defined radiolucent shadow through the Achilles tendon, sharpness of the anterior margin of Achilles tendon, and meniscoid smooth margin of the posterior skin surface of the ankle. Kager's triangle was deformed and disappeared after rupture of the Achilles tendon in nine patients(60%) with operative verification of the rupture, six patients(40%) had a positive Arner's sign, while none had a diminished Toygars angle. In 13 patients(87%) with a ruptured Achilles tendon, the thickness of this was nonuniform compared with the reference group. The anterior margin of the Achilles tendon became serrated and indistinct in 14 patients(93%) in whom this was ruptured. An abnormal ill defined radiolucent shadow through the Achilles tendon was noted in nine patient(60%), and nonparallelism between the anterior margin of the Achilles tendon and posterior skin surface of the ankle was detected in 11 patients(73%). The posterior skin surface of the ankle had a nodular surface margin in 13 patients(87%). A deformed Kager's triangle and Achilles tendon, and an abnormal ill defined radiolucent shadow through the Achilles tendon in a lateral view of the ankles are important findings for the diagnesis of in diagnosing achilles tendon rupture

  2. Effect of administration of oral contraceptives in vivo on collagen synthesis in tendon and muscle connective tissue in young women

    DEFF Research Database (Denmark)

    Hansen, M; Miller, B F; Holm, L

    2009-01-01

    concentrations of estradiol and progesterone (control, n = 12). Subjects performed 1 h of one-legged kicking exercise. The next day collagen fractional synthesis rates (FSR) in tendon and muscle connective tissue were measured after a flooding dose of [(13)C]proline followed by biopsies from the patellar tendon......, body composition, and exercise-training status were included. The two groups were either habitual users of oral contraceptives exposed to a high concentration of synthetic estradiol and progestogens (OC, n = 11), or non-OC-users tested in the follicular phase of the menstrual cycle characterized by low...... bioavailability of IGF-I in OC. In conclusion, synthetic female sex hormones administered as OC had an inhibiting effect on collagen synthesis in tendon, bone, and muscle connective tissue, which may be related to a lower bioavailability of IGF-I....

  3. Tendon Force Transmission at the Nanoscale

    DEFF Research Database (Denmark)

    Svensson, René

    2013-01-01

    of connective tissue function that are poorly understood. One such aspect is the microscopic mechanisms of force transmission through tendons over macroscopic distances. Force transmission is at the heart of tendon function, but the large range of scales in the hierarchical structure of tendons has made...... it difficult to tackle. The tendon hierarchy ranges from molecules (2 nm) over fibrils (200 nm), fibers (2 μm) and fascicles (200 μm) to tendons (10 mm), and to derive the mechanisms of force transmission it is necessary to know the mechanical behavior at each hierarchical level. The aim of the present work...... was to elucidate the mechanisms of force transmission in tendons primarily by investigating the mechanical behavior at the hierarchical level of collagen fibrils. To do so we have developed an atomic force microscopy (AFM) method for tensile testing of native collagen fibrils. The thesis contains five papers...

  4. The combined use of kartogenin and platelet-rich plasma promotes fibrocartilage formation in the wounded rat Achilles tendon entheses.

    Science.gov (United States)

    Zhang, J; Yuan, T; Zheng, N; Zhou, Y; Hogan, M V; Wang, J H-C

    2017-04-01

    After an injury, the biological reattachment of tendon to bone is a challenge because healing takes place between a soft (tendon) and a hard (bone) tissue. Even after healing, the transition zone in the enthesis is not completely regenerated, making it susceptible to re-injury. In this study, we aimed to regenerate Achilles tendon entheses (ATEs) in wounded rats using a combination of kartogenin (KGN) and platelet-rich plasma (PRP). Wounds created in rat ATEs were given three different treatments: kartogenin platelet-rich plasma (KGN-PRP); PRP; or saline (control), followed by histological and immunochemical analyses, and mechanical testing of the rat ATEs after three months of healing. Histological analysis showed well organised arrangement of collagen fibres and proteoglycan formation in the wounded ATEs in the KGN-PRP group. Furthermore, immunohistochemical analysis revealed fibrocartilage formation in the KGN-PRP-treated ATEs, evidenced by the presence of both collagen I and II in the healed ATE. Larger positively stained collagen III areas were found in both PRP and saline groups than those in the KGN-PRP group. Chondrocyte-related genes, SOX9 and collagen II, and tenocyte-related genes, collagen I and scleraxis (SCX), were also upregulated by KGN-PRP. Moreover, mechanical testing results showed higher ultimate tensile strength in the KGN-PRP group than in the saline control group. In contrast, PRP treatment appeared to have healed the injured ATE but induced no apparent formation of fibrocartilage. The saline-treated group showed poor healing without fibrocartilage tissue formation in the ATEs. Our results show that injection of KGN-PRP induces fibrocartilage formation in the wounded rat ATEs. Hence, KGN-PRP may be a clinically relevant, biological approach to regenerate injured enthesis effectively. Cite this article: J. Zhang, T. Yuan, N. Zheng, Y. Zhou, M. V. Hogan, J. H-C. Wang. The combined use of kartogenin and platelet-rich plasma promotes

  5. Arthrography of the biceps tendon

    International Nuclear Information System (INIS)

    Ahovuo, J.; Linden, H.; Hovi, I.; Paavolainen, P.; Bjoerkenheim, J.M.

    1988-01-01

    The purpose of this study was to analyse the factors having an influence on the arthrographic imaging of the biceps tendon. The study comprised 174 patients suffering from chronic shoulder pain. They underwent conventional shoulder arthrography with sodium meglumine metrizoate or metrizamide as a contrast medium. In the patients with a full-thickness tear of the rotator cuff, the biceps tendon sheath failed to fill with contrast medium more often than in those with an intact tendinous cuff. Metrizamide filled the biceps tendon sheath more readily than sodium meglumine metrizoate in patients with a full-thickness tear of the ortator cuff. The volume of the contrast medium injected had no influence on the imaging of the biceps tendon. (orig.)

  6. Effects of the 3D bone-to-implant contact and bone stiffness on the initial stability of a dental implant: micro-CT and resonance frequency analyses.

    Science.gov (United States)

    Hsu, J T; Huang, H L; Tsai, M T; Wu, A Y J; Tu, M G; Fuh, L J

    2013-02-01

    This study investigated the effects of bone stiffness (elastic modulus) and three-dimensional (3D) bone-to-implant contact ratio (BIC%) on the primary stabilities of dental implants using micro-computed tomography (micro-CT) and resonance frequency analyses. Artificial sawbone models with five values of elastic modulus (137, 123, 47.5, 22, and 12.4 MPa) comprising two types of trabecular structure (solid-rigid and cellular-rigid) were investigated for initial implant stability quotient (ISQ), measured using the wireless Osstell resonance frequency analyzer. Bone specimens were attached to 2 mm fibre-filled epoxy sheets mimicking the cortical shell. ISQ was measured after placing a dental implant into the bone specimen. Each bone specimen with an implant was subjected to micro-CT scanning to calculate the 3D BIC% values. The similarity of the cellular type of artificial bone to the trabecular structure might make it more appropriate for obtaining accurate values of primary implant stability than solid-bone blocks. For the cellular-rigid bone models, the ISQ increased with the elastic modulus of cancellous bone. The regression correlation coefficient was 0.96 for correlations of the ISQ with the elasticity of cancellous bone and with the 3D BIC%. The initial implant stability was moderately positively correlated with the elasticity of cancellous bone and with the 3D BIC%. Copyright © 2012 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  7. Flexor digitorum profundus tendon anatomy in the forearm

    Directory of Open Access Journals (Sweden)

    Teoman Dogan

    2012-04-01

    Methods: We used 11 forearms belonging to cadavers and fixed with formaldehyde. The forearms numbered 1, 2, 8, 9, 10, 11 were the left and right arms of the same cadavers. Those numbered 3, 4, 5, 6, 7 belonged to different cadavers. Dissections were made by using the atraumatic surgical technique. The tendons were studied to identify the structure and number of the fibers forming them. Results: The presence of a large common tendon was found in 10 of the 11 forearms. In 4 of these, the common tendon included the tendons of all four fingers. While the common tendon included 3 fingers in four forearms, it only included tendons belonging to 2 fingers in two forearms. It was not possible in one forearm to separate the common tendon into its fibers. In another forearm, tendons belonging to each digit were separate and independent starting at the muscle-tendon junction to the attachment points. Conclusion: The majority of the cadaver forearms used in the study displayed a single large FDP tendon in the zone between the muscle-tendon joint to the carpal tunnel entry prior to being distributed into each index. This anatomical feature should be considered in choosing materials and surgical technique for Zone V FDP tendon injuries, as well as in planning the rehabilitation process. [Hand Microsurg 2012; 1(1.000: 25-29

  8. Porous surface modified bioactive bone cement for enhanced bone bonding.

    Directory of Open Access Journals (Sweden)

    Qiang He

    Full Text Available Polymethylmethacrylate bone cement cannot provide an adhesive chemical bonding to form a stable cement-bone interface. Bioactive bone cements show bone bonding ability, but their clinical application is limited because bone resorption is observed after implantation. Porous polymethylmethacrylate can be achieved with the addition of carboxymethylcellulose, alginate and gelatin microparticles to promote bone ingrowth, but the mechanical properties are too low to be used in orthopedic applications. Bone ingrowth into cement could decrease the possibility of bone resorption and promote the formation of a stable interface. However, scarce literature is reported on bioactive bone cements that allow bone ingrowth. In this paper, we reported a porous surface modified bioactive bone cement with desired mechanical properties, which could allow for bone ingrowth.The porous surface modified bioactive bone cement was evaluated to determine its handling characteristics, mechanical properties and behavior in a simulated body fluid. The in vitro cellular responses of the samples were also investigated in terms of cell attachment, proliferation, and osteoblastic differentiation. Furthermore, bone ingrowth was examined in a rabbit femoral condyle defect model by using micro-CT imaging and histological analysis. The strength of the implant-bone interface was also investigated by push-out tests.The modified bone cement with a low content of bioactive fillers resulted in proper handling characteristics and adequate mechanical properties, but slightly affected its bioactivity. Moreover, the degree of attachment, proliferation and osteogenic differentiation of preosteoblast cells was also increased. The results of the push-out test revealed that higher interfacial bonding strength was achieved with the modified bone cement because of the formation of the apatite layer and the osseointegration after implantation in the bony defect.Our findings suggested a new bioactive

  9. ITO-free inverted polymer/fullerene solar cells: Interface effects and comparison of different semi-transparent front contacts

    NARCIS (Netherlands)

    Wilken, Sebastian; Hoffmann, Thomas; von Hauff, Elizabeth; Borchert, Holger; Parisi, Juergen

    Polymer/fullerene solar cells with an inverted layer sequence and free from indium tin oxide (ITO) are presented in this study. We concentrate on critical interface effects in inverted devices and compare different semi-transparent front contacts, such as ultra-thin Au films and Au grid structures.

  10. IFSSH Flexor Tendon Committee report 2014: from the IFSSH Flexor Tendon Committee (Chairman: Jin Bo Tang).

    Science.gov (United States)

    Tang, Jin Bo; Chang, James; Elliot, David; Lalonde, Donald H; Sandow, Michael; Vögelin, Esther

    2014-01-01

    Hand surgeons continue to search for the best surgical flexor tendon repair and treatment of the tendon sheaths and pulleys, and they are attempting to establish postoperative regimens that fit diverse clinical needs. It is the purpose of this report to present the current views, methods, and suggestions of six senior hand surgeons from six different countries - all experienced in tendon repair and reconstruction. Although certainly there is common ground, the report presents provocative views and approaches. The report reflects an update in the views of the committee. We hope that it is helpful to surgeons and therapists in treating flexor tendon injuries.

  11. Grasp Assist Device with Shared Tendon Actuator Assembly

    Science.gov (United States)

    Ihrke, Chris A. (Inventor); Bergelin, Bryan J. (Inventor); Bridgwater, Lyndon (Inventor)

    2015-01-01

    A grasp assist device includes a glove with first and second tendon-driven fingers, a tendon, and a sleeve with a shared tendon actuator assembly. Tendon ends are connected to the respective first and second fingers. The actuator assembly includes a drive assembly having a drive axis and a tendon hook. The tendon hook, which defines an arcuate surface slot, is linearly translatable along the drive axis via the drive assembly, e.g., a servo motor thereof. The flexible tendon is routed through the surface slot such that the surface slot divides the flexible tendon into two portions each terminating in a respective one of the first and second ends. The drive assembly may include a ball screw and nut. An end cap of the actuator assembly may define two channels through which the respective tendon portions pass. The servo motor may be positioned off-axis with respect to the drive axis.

  12. Effects of chemical intermixing on electrical and thermal contact conductances at metallized bismuth and antimony telluride interfaces

    Energy Technology Data Exchange (ETDEWEB)

    Devender,; Mehta, Rutvik J.; Ramanath, Ganpati, E-mail: Ramanath@rpi.edu [Department of Materials Science and Engineering, Rensselaer Polytechnic Institute, Troy, New York 12180 (United States); Lofgreen, Kelly; Mahajan, Ravi [Intel Corporation, Assembly Test and Technology Development, Chandler, Arizona 85226 (United States); Yamaguchi, Masashi [Department of Physics, Applied Physics and Astronomy, Rensselaer Polytechnic Institute, Troy, New York 12180 (United States); Borca-Tasciuc, Theodorian [Department of Mechanical Aerospace and Nuclear Engineering, Rensselaer Polytechnic Institute, Troy, New York 12180 (United States)

    2015-03-15

    Tailoring electrical and thermal contact conductivities (Σ{sub c} and Γ{sub c}) across metallized pnictogen chalcogenide interfaces is key for realizing efficient thermoelectric devices. The authors report that Cu, Ni, Ti, and Ta diffusion and interfacial telluride formation with n-Bi{sub 2}Te{sub 3} and p-Sb{sub 2}Te{sub 3} influence both Σ{sub c} and Γ{sub c}. Cu metallization yields the highest Γ{sub c} and the lowest Σ{sub c}, correlating with maximal metal diffusion and copper telluride formation. Ni diffuses less and yields the highest Σ{sub c} with Sb{sub 2}Te{sub 3} due to p-type nickel telluride formation, which diminishes Σ{sub c} improvement with n-Bi{sub 2}Te{sub 3} interfaces. Ta and Ti contacts yield the lowest properties similar to that in Ni-metallized structures. These correlations between interfacial diffusion and phase formation on electronic and thermal transport properties will be important for devising suitable metallization for thermoelectric devices.

  13. Effects of transforming growth factor-beta1 and vascular endothelial growth factor 165 gene transfer on Achilles tendon healing.

    Science.gov (United States)

    Hou, Yu; Mao, ZeBin; Wei, XueLei; Lin, Lin; Chen, LianXu; Wang, HaiJun; Fu, Xin; Zhang, JiYing; Yu, Changlong

    2009-07-01

    Repaired Achilles tendons typically take weeks before they are strong enough to handle physiological loads. Gene therapy is a promising treatment for Achilles tendon defects. The aim of the present study was to evaluate the histological/biomechanical effects of Transforming growth factor-beta1 (TGF-beta1) and vascular endothelial growth factor 165 (VEGF(165)) gene transfer on Achilles tendon healing in rabbits. Bone Marrow-Derived Mesenchymal Stem Cells (BMSCs) were transduced with adenovirus carrying human TGF-beta1 cDNA (Ad-TGF-beta1), human VEGF(165) cDNA (Ad-VEGF(165)), or both (PIRES-TGF-beta1/VEGF(165)) Viruses, no cDNA (Ad-GFP), and the BMSCs without gene transfer and the intact tendon were used as control. BMSCs were surgically implanted into the experimentally injured Achilles tendons. TGF-beta1 distribution, cellularity, nuclear aspect ratio, nuclear orientation angle, vascular number, collagen synthesis, and biomechanical features were measured at 1, 2, 4, and 8 weeks after surgery. The TGF-beta1 and TGF beta 1/VEGF(165) co-expression groups exhibited improved parameters compared with other groups, while the VEGF(165) expression group had a negative impact. In the co-expression group, the angiogenesis effects of VEGF(165) were diminished by TGF-beta1, while the collagen synthesis effects of TGF-beta1 were unaltered by VEGF(165). Thus treatment with TGF-beta1 cDNA-transduced BMSCs grafts is a promising therapy for acceleration and improvement of tendon healing, leading to quicker recovery and improved biomechanical properties of Achilles tendons.

  14. Experimental Characterization and Modeling of Thermal Contact Resistance of Electric Machine Stator-to-Cooling Jacket Interface Under Interference Fit Loading

    Energy Technology Data Exchange (ETDEWEB)

    Cousineau, Justine E [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Bennion, Kevin S [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Chieduko, Victor [UQM Technologies, Inc.; Lall, Rajiv [UQM Technologies, Inc.; Gilbert, Alan [UQM Technologies, Inc.

    2018-05-08

    Cooling of electric machines is a key to increasing power density and improving reliability. This paper focuses on the design of a machine using a cooling jacket wrapped around the stator. The thermal contact resistance (TCR) between the electric machine stator and cooling jacket is a significant factor in overall performance and is not well characterized. This interface is typically an interference fit subject to compressive pressure exceeding 5 MPa. An experimental investigation of this interface was carried out using a thermal transmittance setup using pressures between 5 and 10 MPa. The results were compared to currently available models for contact resistance, and one model was adapted for prediction of TCR in future motor designs.

  15. The Effect of Sodium Hyaluronate on Ligamentation and Biomechanical Property of Tendon in Repair of Achilles Tendon Defect with Polyethylene Terephthalate Artificial Ligament: A Rabbit Tendon Repair Model.

    Science.gov (United States)

    Li, Shengkun; Ma, Kui; Li, Hong; Jiang, Jia; Chen, Shiyi

    2016-01-01

    The Achilles tendon is the most common ruptured tendon of human body. Reconstruction with polyethylene terephthalate (PET) artificial ligament is recommended in some serious cases. Sodium hyaluronate (HA) is beneficial for the healing of tendon injuries. We aimed to determine the effect of sodium hyaluronate in repair of Achilles tendon defect with PET artificial ligament in an animal tendon repair model. Sixteen New Zealand White rabbits were divided into two groups. Eight rabbits repaired with PET were assigned to PET group; the other eight rabbits repaired with PET along with injection of HE were assigned to HA-PET group. All rabbits were sacrificed at 4 and 8 weeks postoperatively for biomechanical and histological examination. The HA-PET group revealed higher biomechanical property compared with the PET group. Histologically, more collagen tissues grew into the HA-PET group compared with PET group. In conclusion, application of sodium hyaluronate can improve the healing of Achilles tendon reconstruction with polyethylene terephthalate artificial ligament.

  16. The Effect of Sodium Hyaluronate on Ligamentation and Biomechanical Property of Tendon in Repair of Achilles Tendon Defect with Polyethylene Terephthalate Artificial Ligament: A Rabbit Tendon Repair Model

    Directory of Open Access Journals (Sweden)

    Shengkun Li

    2016-01-01

    Full Text Available The Achilles tendon is the most common ruptured tendon of human body. Reconstruction with polyethylene terephthalate (PET artificial ligament is recommended in some serious cases. Sodium hyaluronate (HA is beneficial for the healing of tendon injuries. We aimed to determine the effect of sodium hyaluronate in repair of Achilles tendon defect with PET artificial ligament in an animal tendon repair model. Sixteen New Zealand White rabbits were divided into two groups. Eight rabbits repaired with PET were assigned to PET group; the other eight rabbits repaired with PET along with injection of HE were assigned to HA-PET group. All rabbits were sacrificed at 4 and 8 weeks postoperatively for biomechanical and histological examination. The HA-PET group revealed higher biomechanical property compared with the PET group. Histologically, more collagen tissues grew into the HA-PET group compared with PET group. In conclusion, application of sodium hyaluronate can improve the healing of Achilles tendon reconstruction with polyethylene terephthalate artificial ligament.

  17. Local vibration enhanced the efficacy of passive exercise on mitigating bone loss in hindlimb unloading rats

    Science.gov (United States)

    Huang, Yunfei; Luan, Huiqin; Sun, Lianwen; Bi, Jingfang; Wang, Ying; Fan, Yubo

    2017-08-01

    Spaceflight induced bone loss is seriously affecting astronauts. Mechanical stimulation from exercise has been shown to restrain bone resorption as well as improve bone formation. Current exercise countermeasures in space cannot prevent it completely. Active exercise may convert to passive exercise in some ways because of the loss of gravity stimulus and inertia of exercise equipment. The aim of this study was to compare the efficacy of passive exercise or/and local vibration on counteracting the deterioration of the musculoskeletal system, including bone, muscle and tendons in tail-suspended rats. We hypothesized that local vibration could enhance the efficacy of passive exercise on countering bone loss. 40 Sprague Dawley rats were randomly distributed into five groups (n = 8, each): tail-suspension (TS), TS+35 Hz vibration (TSV), TS + passive exercise (TSP), TS + passive exercise coupled with 35 Hz vibration (TSPV) and control (CON). Passive exercise or/and local vibration was performed for 21 days. On day 0 and 21, bone mineral density (BMD) was observed by dual energy X-ray absorptiometry (DXA), and trabecular microstructure was evaluated by microcomputer tomography (μCT) analysis in vivo. Mechanical properties of tibia and tendon were determined by a mechanical testing system. Soleus and bone ash weight was tested by an electronic balance. Results showed that the passive exercise could not prevent the decrease of trabecular BMD, microstructure and bone ash weight induced by TS, whereas vibration and passive exercise coupled with local vibration (PV) could. Biomechanical properties of the tibia and tendon in TSPV group significantly increased compared with TS group. In summary, PV in this study was the best method in preventing weightlessness-induced bone loss. Consistent with our hypothesis, local vibration partly enhanced the effect of passive exercise. Furthermore, this study will be useful in improving countermeasure for astronauts, but also for the

  18. Thompson Test in Achilles Tendon Rupture

    Directory of Open Access Journals (Sweden)

    Spencer Albertson

    2016-07-01

    Full Text Available HPI: A 26-year old male presented to the emergency department after experiencing the acute onset of left ankle pain while playing basketball. Upon jumping, he felt a “pop” in his left posterior ankle, followed by pain and difficulty ambulating. His exam was notable for a defect at the left Achilles tendon on palpation. The practitioner performed a Thompson test, which was positive (abnormal on the left. Significant Findings: The left Achilles tendon had a defect on palpation, while the right Achilles tendon was intact. When squeezing the right (unaffected calf, the ankle spontaneously plantar flexed, indicating a negative (normal Thompson test. Upon squeeze of the left (affected calf, the ankle did not plantar flex, signifying a positive (abnormal Thompson test. The diagnosis of left Achilles tendon rupture was confirmed intraoperatively one week later. Discussion: The Achilles tendon (also: calcaneal tendon or heel cord is derived from the medial and lateral heads of the gastrocnemius muscle, as well as the soleus muscle. Rupture of the Achilles tendon most commonly occurs in the distal tendon, approximately 2-6 cm from its attachment to the calcaneal tuberosity, in an area of hypovascularity known as the “watershed” or “critical” zone.1-3 The Thompson test (also: Simmonds-Thompson test, described by Simmonds in 1957 and Thompson in 1962, is done while the patient is in the prone position, with feet hanging over the end of a table/gurney, or with the patient kneeling on a stool or chair.4-5 Squeezing the calf of an unaffected limb will cause the ankle to plantar flex, but squeezing the calf of a limb with an Achilles tendon rupture will cause no motion. The sensitivity of the Thompson’s test for the diagnosis of a complete Achilles tendon rupture is 96-100% and the specificity is 93-100%, but data is limited.6-8

  19. Methods for demonstration of enzyme activity in muscle fibres at the muscle/bone interface in demineralized tissue

    DEFF Research Database (Denmark)

    Kirkeby, S; Vilmann, H

    1981-01-01

    A method for demonstration of activity for ATPase and various oxidative enzymes (succinic dehydrogenase, alpha-glycerophosphate dehydrogenase, and lactic dehydrogenase) in muscle/bone sections of fixed and demineralized tissue has been developed. It was found that it is possible to preserve...... considerable amounts of the above mentioned enzymes in the muscle fibres at the muscle/bone interfaces. The best results were obtained after 20 min fixation, and 2-3 weeks of storage in MgNa2EDTA containing media. As the same technique previously has been used to describe patterns of resorption and deposition...

  20. Repair of full-thickness tendon injury using connective tissue progenitors efficiently derived from human embryonic stem cells and fetal tissues.

    Science.gov (United States)

    Cohen, Shahar; Leshansky, Lucy; Zussman, Eyal; Burman, Michael; Srouji, Samer; Livne, Erella; Abramov, Natalie; Itskovitz-Eldor, Joseph

    2010-10-01

    The use of stem cells for tissue engineering (TE) encourages scientists to design new platforms in the field of regenerative and reconstructive medicine. Human embryonic stem cells (hESC) have been proposed to be an important cell source for cell-based TE applications as well as an exciting tool for investigating the fundamentals of human development. Here, we describe the efficient derivation of connective tissue progenitors (CTPs) from hESC lines and fetal tissues. The CTPs were significantly expanded and induced to generate tendon tissues in vitro, with ultrastructural characteristics and biomechanical properties typical of mature tendons. We describe a simple method for engineering tendon grafts that can successfully repair injured Achilles tendons and restore the ankle joint extension movement in mice. We also show the CTP's ability to differentiate into bone, cartilage, and fat both in vitro and in vivo. This study offers evidence for the possibility of using stem cell-derived engineered grafts to replace missing tissues, and sets a basic platform for future cell-based TE applications in the fields of orthopedics and reconstructive surgery.

  1. Biomechanical and histologic comparison of Achilles tendon ruptures reinforced with intratendinous and peritendinous plantaris tendon grafts in rabbits: an experimental study.

    Science.gov (United States)

    Ilhami, Kuru; Gokhan, Maralcan; Ulukan, Inan; Eray, Bozan M; Levent, Altinel; Ciğdem, Tokyol

    2004-11-01

    We hypothesized that the closer the reinforcing graft was to the repair zone, the more strength the healed tendon would achieved. Therefore, we compared the ruptured rabbit Achilles tendons reinforced with intratendinous and peritendinous plantaris grafts. The experimental study was performed on Achilles tendons of 20 rabbits. First, they were divided into two groups: group I (n=10) underwent intratendinous graft and end-to-end tenorraphy, and group P (n=10) were repaired end-to-end and then reinforced with a peritendinous plantaris graft. An above-knee cast was applied during 6 weeks postoperatively. The two groups were compared to each other biomechanically and histologically. Seven randomly selected rabbits from each group were used for biomechanical evaluation. The remaining six rabbits (three from each group) were used for histologic comparison. Non-operated sides (n=20) served as the control group. The mean maximum load at rupture of the repaired and control groups was 159.9+/-31 N, 83+/-7.5 N, and 207.5+/-35 N for group I, group P, and the control group, respectively. Values between groups were significantly different considering maximum load and absorbed energy to rupture. There was no significant difference between groups I and P in respect to strain. Control group tendons (groups I-C and P-C) had significantly more lengthening capability than operated tendons. Macroscopically, group I tendons were thicker and stiffer than group P tendons. Histologically, differences between the group I and group P specimens revealed that the healing process was faster in tendons augmented intratendinously. In reinforcing Achilles tendon repair, the site of the tendon graft affected the result. When the graft was used intratendinously, the healed tendon was more similar biomechanically to normal tendon and had more graft-tendon orientation histologically than the tendon augmented peritendinously.

  2. Evolutionary origins of C-terminal (GPPn 3-hydroxyproline formation in vertebrate tendon collagen.

    Directory of Open Access Journals (Sweden)

    David M Hudson

    Full Text Available Approximately half the proline residues in fibrillar collagen are hydroxylated. The predominant form is 4-hydroxyproline, which helps fold and stabilize the triple helix. A minor form, 3-hydroxyproline, still has no clear function. Using peptide mass spectrometry, we recently revealed several previously unknown molecular sites of 3-hydroxyproline in fibrillar collagen chains. In fibril-forming A-clade collagen chains, four new partially occupied 3-hydroxyproline sites were found (A2, A3, A4 and (GPPn in addition to the fully occupied A1 site at Pro986. The C-terminal (GPPn motif has five consecutive GPP triplets in α1(I, four in α2(I and three in α1(II, all subject to 3-hydroxylation. The evolutionary origins of this substrate sequence were investigated by surveying the pattern of its 3-hydroxyproline occupancy from early chordates through amphibians, birds and mammals. Different tissue sources of type I collagen (tendon, bone and skin and type II collagen (cartilage and notochord were examined by mass spectrometry. The (GPPn domain was found to be a major substrate for 3-hydroxylation only in vertebrate fibrillar collagens. In higher vertebrates (mouse, bovine and human, up to five 3-hydroxyproline residues per (GPPn motif were found in α1(I and four in α2(I, with an average of two residues per chain. In vertebrate type I collagen the modification exhibited clear tissue specificity, with 3-hydroxyproline prominent only in tendon. The occupancy also showed developmental changes in Achilles tendon, with increasing 3-hydroxyproline levels with age. The biological significance is unclear but the level of 3-hydroxylation at the (GPPn site appears to have increased as tendons evolved and shows both tendon type and developmental variations within a species.

  3. Electrical and structural properties of surfaces and interfaces in Ti/Al/Ni Ohmic contacts to p-type implanted 4H-SiC

    Science.gov (United States)

    Vivona, M.; Greco, G.; Bongiorno, C.; Lo Nigro, R.; Scalese, S.; Roccaforte, F.

    2017-10-01

    In this work, the electrical and structural properties of Ti/Al/Ni Ohmic contacts to p-type implanted silicon carbide (4H-SiC) were studied employing different techniques. With increasing the annealing temperature, an improvement of the electrical properties of the contacts is highlighted, until an Ohmic behavior is obtained at 950 °C, with a specific contact resistance ρc = 2.3 × 10-4 Ω cm2. A considerable intermixing of the metal layers occurred upon annealing, as a consequence of the formation of different phases, both in the uppermost part of the stack (mainly Al3Ni2) and at the interface with SiC, where the formation of preferentially aligned TiC is observed. The formation of an Ohmic contact was associated with the occurrence of the reaction and the disorder at the interface, where the current transport is dominated by the thermionic field emission mechanism with a barrier height of 0.56 eV.

  4. Simultaneous bilateral patellar tendon rupture ?

    OpenAIRE

    Moura, Diogo Lino; Marques, Jos? Pedro; Lucas, Francisco Manuel; Fonseca, Fernando Pereira

    2016-01-01

    Bilateral patellar tendon rupture is a rare entity, often associated with systemic diseases and patellar tendinopathy. The authors report a rare case of a 34-year-old man with simultaneous bilateral rupture of the patellar tendon caused by minor trauma. The patient is a retired basketball player with no past complaints of chronic knee pain and a history of steroid use. Surgical management consisted in primary end-to-end tendon repair protected temporarily with cerclage wiring, followed by a s...

  5. Exercise and Regulation of Bone and Collagen Tissue Biology

    DEFF Research Database (Denmark)

    Kjaer, Michael; Jørgensen, Niklas Rye; Heinemeier, Katja

    2015-01-01

    The musculoskeletal system and its connective tissue include the intramuscular connective tissue, the myotendinous junction, the tendon, the joints with their cartilage and ligaments, and the bone; they all together play a crucial role in maintaining the architecture of the skeletal muscle, ensur...

  6. FRP tendon anchorage in post-tensioned concrete structures

    DEFF Research Database (Denmark)

    Schmidt, Jacob Wittrup; Täljsten, Björn; Bennitz, Anders

    2008-01-01

    effective Young´s modulus and the high stress capacity in the linear elastic range of the material. The use of external tendons increases the requirements on the anchorage systems. This is in particular important when using un-bonded tendon systems, where the anchorage and deviators are the only force...... transfer points. The demand for high capacity anchorage tendons is fulfilled for steel tendons, but no competitive mechanical anchor has yet been developed for FRP tendon. A new small, reliable and more user friendly anchor has to be developed, before FRP tendons can be utilized with all of its capacity...

  7. MR Imaging and US of the Wrist Tendons.

    Science.gov (United States)

    Plotkin, Benjamin; Sampath, Srihari C; Sampath, Srinath C; Motamedi, Kambiz

    2016-10-01

    The tendons of the wrist are commonly symptomatic. They can be injured, infected, or inflamed. Magnetic resonance imaging and ultrasonography are useful tools for evaluating the wrist. Pathologic conditions of the wrist tendons include de Quervain tenosynovitis, extensor carpi ulnaris tendinopathy, rheumatoid tenosynovitis, infectious synovitis, tendon tears, hydroxyapatite deposition disease, intersection syndrome, tenosynovial giant cell tumor, and fibroma of the tendon sheath. In this article, we review the normal appearance of the wrist tendons, discuss relevant anatomy, and give an overview of common pathologic conditions affecting the wrist tendons. Online supplemental material is available for this article. © RSNA, 2016.

  8. No effect of Osteoset, a bone graft substitute, on bone healing in humans: a prospective randomized double-blind study

    DEFF Research Database (Denmark)

    Petruskevicius, Juozas; Nielsen, Mette Strange; Kaalund, Søren

    2002-01-01

    We studied the effects of a newly marketed bone substitute, Osteoset, on bone healing in a tibial defect in humans. 20 patients undergoing an ACL (anterior cruciate ligament) reconstruction with bone-patella tendon-bone graft were block-randomized into 2 groups of 10 each. In the treatment group......, the tibial defect was filled manually with Osteoset pellets, in the control group the defect was left empty. CTs of the defect were taken on the first day after the operation, 6 weeks, 3 and 6 months postoperatively. We found about the same amount of bone in the defect in the Osteoset and control groups...... after 6 weeks, 3, and 6 months. In the control group, but not in the Osteoset group, the bone volume increased from 6 weeks to 3 months. The Osteoset pellets were almost resorbed after 6 weeks....

  9. Effect of pool turbulence on direct contact condensation at a steam/water interface

    International Nuclear Information System (INIS)

    Jackson, J.D.; Zhao, C.L.; Doerffer, S.; Byrne, J.E.; Falaki, H.

    2000-01-01

    Measurements of direct contact condensation beat transfer have been made for the case where the process takes place at the horizontal interface between saturated steam and a pool of water in a vertical cylindrical test section. A submerged vertical jet of subcooled water was injected upwards on the axis to promote the condensation and water was withdrawn at the same rate from the bottom of the pool. In conjunction with the above study, measurements of the turbulent velocity fluctuations just below a free surface produced by the injection of a vertical submerged jet have been measured using hot film anemometry on an isothermal air-water test facility of similar geometry for similar flow conditions at ambient temperature. A correlation is proposed in terms of a Stanton number based on turbulent velocity fluctuation near the interface on the liquid-side. Our results are in good agreement with those of others for similar configurations when compared in terms of condensation Stanton number. (author)

  10. Tactile and bone-conduction auditory brain computer interface for vision and hearing impaired users.

    Science.gov (United States)

    Rutkowski, Tomasz M; Mori, Hiromu

    2015-04-15

    The paper presents a report on the recently developed BCI alternative for users suffering from impaired vision (lack of focus or eye-movements) or from the so-called "ear-blocking-syndrome" (limited hearing). We report on our recent studies of the extents to which vibrotactile stimuli delivered to the head of a user can serve as a platform for a brain computer interface (BCI) paradigm. In the proposed tactile and bone-conduction auditory BCI novel multiple head positions are used to evoke combined somatosensory and auditory (via the bone conduction effect) P300 brain responses, in order to define a multimodal tactile and bone-conduction auditory brain computer interface (tbcaBCI). In order to further remove EEG interferences and to improve P300 response classification synchrosqueezing transform (SST) is applied. SST outperforms the classical time-frequency analysis methods of the non-linear and non-stationary signals such as EEG. The proposed method is also computationally more effective comparing to the empirical mode decomposition. The SST filtering allows for online EEG preprocessing application which is essential in the case of BCI. Experimental results with healthy BCI-naive users performing online tbcaBCI, validate the paradigm, while the feasibility of the concept is illuminated through information transfer rate case studies. We present a comparison of the proposed SST-based preprocessing method, combined with a logistic regression (LR) classifier, together with classical preprocessing and LDA-based classification BCI techniques. The proposed tbcaBCI paradigm together with data-driven preprocessing methods are a step forward in robust BCI applications research. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. Repair of Achilles tendon defect with autologous ASCs engineered tendon in a rabbit model.

    Science.gov (United States)

    Deng, Dan; Wang, Wenbo; Wang, Bin; Zhang, Peihua; Zhou, Guangdong; Zhang, Wen Jie; Cao, Yilin; Liu, Wei

    2014-10-01

    Adipose derived stem cells (ASCs) are an important cell source for tissue regeneration and have been demonstrated the potential of tenogenic differentiation in vitro. This study explored the feasibility of using ASCs for engineered tendon repair in vivo in a rabbit Achilles tendon model. Total 30 rabbits were involved in this study. A composite tendon scaffold composed of an inner part of polyglycolic acid (PGA) unwoven fibers and an outer part of a net knitted with PGA/PLA (polylactic acid) fibers was used to provide mechanical strength. Autologous ASCs were harvested from nuchal subcutaneous adipose tissues and in vitro expanded. The expanded ASCs were harvested and resuspended in culture medium and evenly seeded onto the scaffold in the experimental group, whereas cell-free scaffolds served as the control group. The constructs of both groups were cultured inside a bioreactor under dynamic stretch for 5 weeks. In each of 30 rabbits, a 2 cm defect was created on right side of Achilles tendon followed by the transplantation of a 3 cm cell-seeded scaffold in the experimental group of 15 rabbits, or by the transplantation of a 3 cm cell-free scaffold in the control group of 15 rabbits. Animals were sacrificed at 12, 21 and 45 weeks post-surgery for gross view, histology, and mechanical analysis. The results showed that short term in vitro culture enabled ASCs to produce matrix on the PGA fibers and the constructs showed tensile strength around 50 MPa in both groups (p > 0.05). With the increase of implantation time, cell-seeded constructs gradually form neo-tendon and became more mature at 45 weeks with histological structure similar to that of native tendon and with the presence of bipolar pattern and D-periodic structure of formed collagen fibrils. Additionally, both collagen fibril diameters and tensile strength increased continuously with significant difference among different time points (p tendon tissue with fibril structure observable only at 45 weeks

  12. Peroneal tendon displacement accompanying intra-articular calcaneal fractures.

    Science.gov (United States)

    Toussaint, Rull James; Lin, Darius; Ehrlichman, Lauren K; Ellington, J Kent; Strasser, Nicholas; Kwon, John Y

    2014-02-19

    Peroneal tendon displacement (subluxation or dislocation) accompanying an intra-articular calcaneal fracture is often undetected and under-treated. The goals of this study were to determine (1) the prevalence of peroneal tendon displacement accompanying intra-articular calcaneal fractures, (2) the association of tendon displacement with fracture classifications, (3) the association of tendon displacement with heel width, and (4) the rate of missed diagnosis of the tendon displacement on radiographs and computed tomography (CT) scans and the resulting treatment rate. A retrospective radiographic review of all calcaneal fractures presenting at three institutions from June 30, 2006, to June 30, 2011, was performed. CT imaging of 421 intra-articular calcaneal fractures involving the posterior facet was available for review. The prevalence of peroneal tendon displacement was noted and its associations with fracture classification and heel width were evaluated. Peroneal tendon displacement was identified in 118 (28.0%) of the 421 calcaneal fracture cases. The presence of tendon displacement was significantly associated with joint-depression fractures compared with tongue-type fractures (p displacement had been identified in the radiology reports. Although sixty-five (55.1%) of the fractures with tendon displacement had been treated with internal fixation, the tendon displacement was treated surgically in only seven (10.8%) of these cases. Analysis of CT images showed a 28% prevalence of peroneal tendon displacement accompanying intra-articular calcaneal fractures. Surgeons and radiologists are encouraged to consider this association.

  13. VEGF and BFGF Expression and Histological Characteristics of the Bone-Tendon Junction during Acute Injury Healing

    Directory of Open Access Journals (Sweden)

    Lin Wang

    2014-03-01

    Full Text Available Bone-tendon junction (BTJ injuries are common and may be caused by acute trauma and delayed healing during exercise or work. To understand the nature of the healing process of BTJ injuries would help to prevent injuries and improve treatment. Thirty-three mature female rabbit hindlimbs were assigned to normal control (CON, n = 7 and injury groups (n = 26. The acute injury was established by administering one 7 plum-blossom needle puncture. Specimens were harvested post injury at 1, 2, 4, and 8 weeks (ND1W, n = 6; ND2W, n = 6; ND4W, n = 7; and ND8W, n = 7. The injury existed in all of the injury groups. Compared with the CON group, all of the animals in the injury group showed poor cell profiles, an unclear or undetectable tide mark, a proteoglycan area and profile changes; the BTJ cell density diminished significantly in the ND1W (p 0.05. The basic fibroblast growth factor (bFGF expression in the CON group was significantly less than in the ND1W group (p 0.05. The bFGF and VEGF expression levels indicated that the healing process stopped at 8 weeks post injury or was not activated, although the injury had not healed by histological examination. A repeatable animal model of BTJ acute injury was established in this study, and the results described the BTJ acute injury healing difficult concerned with the repairing stop.

  14. Three-dimensional structure of laser-modified Ti6Al4V and bone interface revealed with STEM tomography

    International Nuclear Information System (INIS)

    Grandfield, Kathryn; Palmquist, Anders; Engqvist, Håkan

    2013-01-01

    The early interaction between an implant's surface and bone is a leading factor for implant success, where multiple surface properties contribute to improved bone anchorage. An important parameter is surface topography, both on the micron and nanoscale. Laser-modification has been performed in the thread valleys of Ti6Al4V screws to alter their surface chemistry and topography to form a nanostructured surface titanium-dioxide. Implants were placed in the rabbit tibia, removed with surrounding bone after 8 weeks, fixated, dried and resin embedded. Focused ion beam milling (FIB) was used to prepare specimens from the resin blocks for transmission electron microscopy (TEM). Z-contrast electron tomography offered the possibility to explore the interfacial structure with high-resolution in three-dimensions. With this technique, collagen fibers of the surrounding bone appear to have been laid down parallel to the implant surface. Accordingly, visualization of the laser-modified interface with nanoscale three-dimensional resolution, as offered by Z-contrast electron tomography, gives new insights into bone bonding mechanisms between roughened titanium-dioxide surfaces and bone

  15. Braided and Stacked Electrospun Nanofibrous Scaffolds for Tendon and Ligament Tissue Engineering.

    Science.gov (United States)

    Rothrauff, Benjamin B; Lauro, Brian B; Yang, Guang; Debski, Richard E; Musahl, Volker; Tuan, Rocky S

    2017-05-01

    Tendon and ligament injuries are a persistent orthopedic challenge given their poor innate healing capacity. Nonwoven electrospun nanofibrous scaffolds composed of polyesters have been used to mimic the mechanics and topographical cues of native tendons and ligaments. However, nonwoven nanofibers have several limitations that prevent broader clinical application, including poor cell infiltration, as well as tensile and suture-retention strengths that are inferior to native tissues. In this study, multilayered scaffolds of aligned electrospun nanofibers of two designs-stacked or braided-were fabricated. Mechanical properties, including structural and mechanical properties and suture-retention strength, were determined using acellular scaffolds. Human bone marrow-derived mesenchymal stem cells (MSCs) were seeded on scaffolds for up to 28 days, and assays for tenogenic differentiation, histology, and biochemical composition were performed. Braided scaffolds exhibited improved tensile and suture-retention strengths, but reduced moduli. Both scaffold designs supported expression of tenogenic markers, although the effect was greater on braided scaffolds. Conversely, cell infiltration was superior in stacked constructs, resulting in enhanced cell number, total collagen content, and total sulfated glycosaminoglycan content. However, when normalized against cell number, both designs modulated extracellular matrix protein deposition to a similar degree. Taken together, this study demonstrates that multilayered scaffolds of aligned electrospun nanofibers supported tenogenic differentiation of seeded MSCs, but the macroarchitecture is an important consideration for applications of tendon and ligament tissue engineering.

  16. Fracture-mechanical assessment of electrically permeable interface cracks in piezoelectric bimaterials by consideration of various contact zone models

    NARCIS (Netherlands)

    Herrmann, KP; Loboda, VV

    An interface crack with an artificial contact zone at the right-hand side crack tip between two piezoelectric semi-infinite half-planes is considered under remote mixed-mode loading. Assuming the stresses, strains and displacements are independent of the coordinate x(2), the expression for the

  17. The 'bridging sign', a MR finding for combined full-thickness tears of the subscapularis tendon and the supraspinatus tendon

    International Nuclear Information System (INIS)

    Jung, Jin Young; Yoon, Young Cheol; Cha, Dong Ik; Yoo, Jae-Chul; Jung, Jee Young

    2013-01-01

    Background: In daily practice, we discovered one of the secondary magnetic resonance (MR) findings of the subscapularis (SSC) tendon tear, the 'bridging sign', which has not been previously described. Purpose: To describe the 'bridging sign' on shoulder MR imaging and its radiological and clinical significance in patients with SSC tendon tear. Material and Methods: Twenty-nine patients who had undergone shoulder arthroscopy and had full-thickness tear of the subscapularis tendon were enrolled. The medical records of the 29 patients were retrospectively reviewed for the duration of shoulder pain, rotator cuff tears, and associated arthroscopic findings: biceps tendon abnormality and superior glenoid labral tear. Then, preoperative shoulder MR images were retrospectively reviewed for the presence or absence of the 'bridging sign' and associated MR findings: periarticular fluid and fatty atrophy of the supraspinatus and subscapularis muscles. The type of rotator cuff tear associated with the 'bridging sign' was assessed and the sensitivity, specificity, and accuracy of the 'bridging sign' for the diagnosis of a certain type of rotator cuff tear were calculated. Associated arthroscopic and MR findings and mean duration of the shoulder pain between the patients with and without the 'bridging sign' were compared. Results: The 'bridging sign' was seen in 17 of 29 patients and corresponded to a complex of the torn and superomedially retracted subscapularis tendon, coracohumeral ligament, and superior glenohumeral ligament, adhered to the anterior margin of the torn supraspinatus (SSP) tendon on arthroscopy. All patients with the 'bridging sign' had combined full-thickness tear (FTT) of the cranial 1/2 portion of the subscapularis tendon and anterior 1/2 portion of the SSP tendon. The sensitivity, specificity, and accuracy of the 'bridging sign' for the diagnosis of combined FTTs of the SSC tendon and anterior portion of the SSP tendon were 81.0%, 100%, and 86

  18. MR imaging findings of painful type II accessory navicular bone: correlation with surgical and pathologic studies

    International Nuclear Information System (INIS)

    Choi, Yun Sun; Lee, Kyung Tai; Kim, Eun Kyung; Kang, Heung Sik

    2004-01-01

    To evaluate the MR imaging findings of painful type II accessory navicular bone and to correlate these with the surgical and pathologic findings. The MR images of 17 patients with medial foot pain and surgically proven type II accessory navicular abnormalities were reviewed. The changes of signal intensity in the accessory navicular, synchondrosis and adjacent soft tissue, the presence of synchondrosis widening, and posterior tibial tendon (PTT) pathology on the T1-weighted and fat-suppressed T2-weighted images were analyzed. The MR imaging findings were compared with the surgical and pathologic findings. The fat-suppressed T2-weighted images showed high signal intensity in the accessory navicular bones and synchondroses in all patients, and in the soft tissue in 11 (64.7%) of the 17 patients, as well as synchondrosis widening in 3 (17.6%) of the 17 patients. The MR images showed tendon pathology in 12 (75%) of the 16 patients with PTT dysfunction at surgery. The pathologic findings of 16 surgical specimens included areas of osteonecrosis with granulomatous inflammation, fibrosis and destruction of the cartilage cap. The MR imaging findings of painful type II accessory navicular bone are a persistent edema pattern in the accessory navicular bone and within the synchondrosis, indicating osteonecrosis, inflammation and destruction of the cartilage cap. Posterior tibial tendon dysfunction was clinically evident in most patients

  19. Imaging the infrapatellar tendon in the elite athlete

    International Nuclear Information System (INIS)

    Peace, K.A.L.; Lee, J.C.; Healy, J.

    2006-01-01

    Extensor mechanism injuries constitute a major cause of anterior knee pain in the elite athlete. Sonography and magnetic resonance imaging (MRI) are the imaging methods of choice when assessing the infrapatellar tendon. A comprehensive imaging review of infrapatellar tendon normal anatomy, tendinopathy, and partial/full-thickness tendon tears is provided. The value of imaging the infrapatellar tendon in clinical practice, including whether sonography can predict symptoms in asymptomatic athletes, is discussed. Acute avulsion fractures, including periosteal sleeve avulsion, and chronic avulsion injuries, including Sinding-Larsen-Johansson and Osgood-Schlatter syndromes, are shown. Mimics of infrapatellar tendon pathology, including infrapatellar plica injury, patellar tendon-lateral femoral condyle friction syndrome, and Hoffa's syndrome, are illustrated

  20. About tendon tissue regeneration in experimental radiation disease

    Energy Technology Data Exchange (ETDEWEB)

    Popov, D; Trichkova, P

    1976-01-01

    Under the conditions of experimental acute radiation disease the authors study the tendon tissue regeneration after suture of the lateral part of the gastrocnemius muscle tendon. Tendon auto and alloplasty were applied. In four postoperative periods the histological features are described in details as well as the characteristic phenomena observed during the regeneration influenced to a considerable degree by the irradiation. Round cell infiltration, large necrotic zones, erythrocyte infiltrations as well as predominance of non-specific tendon regeneration long after the surgery characterize the recovery period of the traumatically damaged tendon, nevertheless that at the end there is real tendon regeneration even though in a longer period in comparison with the controls (non-irradiated animals).

  1. Study of new sheep bone and Zn/Ca ratio around TiAlV screw: PIXE RBS analysis

    Science.gov (United States)

    Guibert, G.; Munnik, F.; Langhoff, J. D.; Von Rechenberg, B.; Buffat, Ph. A.; Laub, D.; Faber, L.; Ducret, F.; Gerber, I.; Mikhailov, S.

    2008-03-01

    This study reports on in vivo particle induced X-ray emission (PIXE) measurements combined with Rutherford backscattering spectroscopy (RBS) analyses of new remodeled sheep bone formed around TiAlV screws. The implants (screws) were anodized by a modified TiMax™ process. The interface between the implant and the bone was carefully investigated. [Zn]/[Ca] in-depth composition profiles as well as Ca, Fe elemental maps were recorded. The thickness of new bone formed around the screw reached 300-400 μm. Osteon and Osteoid phases were identified in the new bone. A higher [Zn]/[Ca] ratio was observed in the new bone as compared to the mature bone. Blood vessels were observed in the bone in close contact with the screw. This study shows the potential of ion beam analysis for biological and biomedical characterization.

  2. Study of new sheep bone and Zn/Ca ratio around TiAlV screw: PIXE-RBS analysis

    International Nuclear Information System (INIS)

    Guibert, G.; Munnik, F.; Langhoff, J.D.; Von Rechenberg, B.; Buffat, Ph.A.; Laub, D.; Faber, L.; Ducret, F.; Gerber, I.; Mikhailov, S.

    2008-01-01

    This study reports on in vivo particle induced X-ray emission (PIXE) measurements combined with Rutherford backscattering spectroscopy (RBS) analyses of new remodeled sheep bone formed around TiAlV screws. The implants (screws) were anodized by a modified TiMax TM process. The interface between the implant and the bone was carefully investigated. [Zn]/[Ca] in-depth composition profiles as well as Ca, Fe elemental maps were recorded. The thickness of new bone formed around the screw reached 300-400 μm. Osteon and Osteoid phases were identified in the new bone. A higher [Zn]/[Ca] ratio was observed in the new bone as compared to the mature bone. Blood vessels were observed in the bone in close contact with the screw. This study shows the potential of ion beam analysis for biological and biomedical characterization

  3. Suppression of material transfer at contacting surfaces: the effect of adsorbates on Al/TiN and Cu/diamond interfaces from first-principles calculations

    Science.gov (United States)

    Feldbauer, Gregor; Wolloch, Michael; Bedolla, Pedro O.; Redinger, Josef; Vernes, András; Mohn, Peter

    2018-03-01

    The effect of monolayers of oxygen (O) and hydrogen (H) on the possibility of material transfer at aluminium/titanium nitride (Al/TiN) and copper/diamond (Cu/Cdia) interfaces, respectively, were investigated within the framework of density functional theory (DFT). To this end the approach, contact, and subsequent separation of two atomically flat surfaces consisting of the aforementioned pairs of materials were simulated. These calculations were performed for the clean as well as oxygenated and hydrogenated Al and Cdia surfaces, respectively. Various contact configurations were considered by studying several lateral arrangements of the involved surfaces at the interface. Material transfer is typically possible at interfaces between the investigated clean surfaces; however, the addition of O to the Al and H to the Cdia surfaces was found to hinder material transfer. This passivation occurs because of a significant reduction of the adhesion energy at the examined interfaces, which can be explained by the distinct bonding situations.

  4. Spontaneous Achilles tendon rupture in alkaptonuria | Mohammed ...

    African Journals Online (AJOL)

    Spontaneous Achilles tendon ruptures are uncommon. We present a 46-year-old man with spontaneous Achilles tendon rupture due to ochronosis. To our knowledge, this has not been previously reported in Sudan literature. The tendon of the reported patient healed well after debridement and primary repairs.

  5. Efficacy of bone marrow-stimulating technique in rotator cuff repair.

    Science.gov (United States)

    Bilsel, Kerem; Yildiz, Fatih; Kapicioglu, Mehmet; Uzer, Gokcer; Elmadag, Mehmet; Pulatkan, Anil; Esrefoglu, Mukaddes; Bozdag, Ergun; Milano, Giuseppe

    2017-08-01

    This study used a chronic rotator cuff (RC) tear model to investigate the effect of microfracture as a bone marrow-stimulating (BMS) technique for RC healing. A chronic retracted RC tendon tear model was created bilaterally in the subscapularis tendons of 20 New Zealand rabbits. The tendons were repaired after 8 weeks using a single-row configuration. Tendons in the right shoulder were repaired in standard fashion (control group). Microfractures were performed in the left shoulders before repair (microfracture group). The animals were euthanized 8 and 16 weeks after repair. The repaired tendons were tested biomechanically for their ultimate failure load, linear stiffness, and elongation at failure. Gross and histologic evaluations of the tendon-to-bone healing were evaluated. Macroscopically, subscapularis tendons were attached on the lesser tuberosity. In the microfracture group, collagen fibers were organized in relatively thicker bundles. The mean ultimate failure load of the microfracture group was significantly greater at 8 weeks (148.4 ± 31 N vs. 101.4 ± 26 N, respectively; P = .011) and 16 weeks (155 ± 30 N vs. 114.9 ± 25 N, respectively; P = .017) after repair. There were no significant differences between the groups for linear stiffness at 8 weeks (15.9 ± 2.7 N/mm vs. 15.8 ± 1.3 N/mm, respectively; P = .798) and 16 weeks (16.9 ± 4.3 N/mm vs. 17.1 ± 3.6 N/mm, respectively, P = .848) and elongation at failure at 8 weeks (4.7 ± 1.1 mm vs. 4.7 ± 1.3 mm, respectively; P = .848) and 16 weels (4.8 ± 1.5 mm vs. 4.9 ± 0.9 mm, respectively; P = .749). The microfracture on the tuberosity of the repaired chronic rotator cuff tear promoted dynamic tendon healing with significantly increased ultimate force to failure and with thicker collagen bundles and more fibrocartilage histologically at 8 weeks. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of

  6. Plantar tendons of the foot: MR imaging and US.

    Science.gov (United States)

    Donovan, Andrea; Rosenberg, Zehava Sadka; Bencardino, Jenny T; Velez, Zoraida Restrepo; Blonder, David B; Ciavarra, Gina A; Adler, Ronald Steven

    2013-01-01

    Tendon disorders along the plantar aspect of the foot may lead to significant symptoms but are often clinically misdiagnosed. Familiarity with the normal anatomy of the plantar tendons and its appearance at magnetic resonance (MR) imaging and ultrasonography (US) is essential for recognizing plantar tendon disorders. At MR imaging, the course of the plantar tendons is optimally visualized with dedicated imaging of the midfoot and forefoot. This imaging should include short-axis images obtained perpendicular to the long axis of the metatarsal shafts, which allows true cross-sectional evaluation of the plantar tendons. Normal plantar tendons appear as low-signal-intensity structures with all MR sequences. At US, accurate evaluation of the tendons requires that the ultrasound beam be perpendicular to the tendon. The normal tendon appears as a compact linear band of echogenic tissue that contains a fine, mixed hypoechoic and hyperechoic internal fibrillar pattern. Tendon injuries can be grouped into six major categories: tendinosis, peritendinosis, tenosynovitis, entrapment, rupture, and instability (subluxation or dislocation) and can be well assessed with both MR imaging and US. The radiologist plays an important role in the diagnosis of plantar tendon disorders, and recognizing their imaging appearances at MR imaging and US is essential.

  7. Improving the electrical contact at a Pt/TiO2 nanowire interface by selective application of focused femtosecond laser irradiation

    Science.gov (United States)

    Xing, Songling; Lin, Luchan; Zou, Guisheng; Liu, Lei; Peng, Peng; Wu, Aiping; Duley, Walter W.; Zhou, Y. Norman

    2017-10-01

    In this paper, we show that tightly focused femtosecond laser irradiation is effective in improving nanojoining of an oxide nanowire (NW) (TiO2) to a metal electrode (Pt), and how this process can be used to modify contact states. Enhanced chemical bondings are created due to localized plasmonically enhanced optical absorption at the Pt/TiO2 interface as confirmed by finite element simulations of the localized field distribution during irradiation. Nano Auger electron spectroscopy shows that the resulting heterojunction is depleted in oxygen, suggesting that a TiO2-x layer is formed between the Pt electrode and the TiO2 NW. The presence of this redox layer at the metal/oxide interface plays an important role in decreasing the Schottky barrier height and in facilitating chemical bonding. After laser irradiation at the cathode for 10 s at a fluence of 5.02 mJ cm-2, the Pt/TiO2 NW/Pt structure displays different electrical properties under forward and reverse bias voltage, respectively. The creation of this asymmetric electrical characteristic shows the way in which modification of the electronic interface by laser engineering can replace the electroforming process in resistive switching devices and how it can be used to control contact states in a metal/oxide interface.

  8. Methods for histochemical demonstration of vascular structures at the muscle-bone interface from cryostate sections of demineralized tissue

    DEFF Research Database (Denmark)

    Kirkeby, S

    1981-01-01

    In tissue decalcified with MgNa2EDTA at a neutral pH activity for ATPase can used be for demonstration of the vascular structures at the muscle-bone interface. The GOMORI method for alkaline phosphatase is only of value, when fresh unfixed tissue is to be examined. The azo-dye method for alkaline...... phosphatase failed to give satisfactory results, and so did the alpha-amylase PAS method. 5'-nucleotidase activity is present in both capillaries and in cells lining the surfaces of bones, while larger blood vessels are poorly stained....

  9. Mechanical properties of the human Achilles tendon, in vivo

    DEFF Research Database (Denmark)

    Kongsgaard, M; Nielsen, C H; Hegnsvad, S

    2011-01-01

    Ultrasonography has been widely applied for in vivo measurements of tendon mechanical properties. Assessments of human Achilles tendon mechanical properties have received great interest. Achilles tendon injuries predominantly occur in the tendon region between the Achilles-soleus myotendinous...... junction and Achilles-calcaneus osteotendinous junction i.e. in the free Achilles tendon. However, there has been no adequate ultrasound based method for quantifying the mechanical properties of the free human Achilles tendon. This study aimed to: 1) examine the mechanical properties of the free human...

  10. Reversibility of Supraspinatus Muscle Atrophy in Tendon-Bone Healing After Arthroscopic Rotator Cuff Repair.

    Science.gov (United States)

    Park, Yong Bok; Ryu, Ho Young; Hong, Jin Ho; Ko, Young Hoo; Yoo, Jae Chul

    2016-04-01

    To date, there are few reports of the definite reversibility of rotator cuff muscle atrophy after repair. To evaluate the reversibility of rotator cuff muscle atrophy after successful arthroscopic repair. Case series; Level of evidence, 4. Included in this study were 47 patients (mean age, 61.2 ± 7.3 years; range, 49-73 years) who underwent arthroscopic rotator cuff repair as well as magnetic resonance imaging (MRI) preoperatively and at 6-month and last follow-up. Patients who had confirmed rotator cuff healing (grades 1-3 according to the Sugaya classification) on both series of postoperative MRI were enrolled in the study. The mean time from the onset of symptoms to surgery was 24.7 ± 25.6 months (range, 3-120 months). The minimum follow-up was 2 years, and the mean follow-up duration was 41.8 ± 14.4 months. Serial changes in the supraspinatus muscle area on the most matching MRI scans (sagittal-oblique view) were evaluated. The area was measured by 2 independent observers. Both independent observers reported no significant difference in the area of the supraspinatus muscle between the preoperative time point and 6-month follow-up (observer 1: P = .135; observer 2: P = .189). However, there was a significant difference between the 6-month and last follow-up (mean, 41.8 months; observers 1 and 2: P .999) or from 6-month to final follow-up (P = .077). After successful arthroscopic rotator cuff repair, there was a slight (11.3%-13.9%) increase in muscle volume from preoperatively to final follow-up, as seen on serial MRI. Fatty infiltration according to the Goutallier grade was not reversed (P = .077). Some reversibility of supraspinatus muscle atrophy may exist in tendon-bone healing after arthroscopic rotator cuff repair; further follow-up is needed to better elucidate this result. © 2016 The Author(s).

  11. A Tendon Cell Specific RNAi Screen Reveals Novel Candidates Essential for Muscle Tendon Interaction.

    Directory of Open Access Journals (Sweden)

    Prabhat Tiwari

    Full Text Available Tendons are fibrous connective tissue which connect muscles to the skeletal elements thus acting as passive transmitters of force during locomotion and provide appropriate body posture. Tendon-derived cues, albeit poorly understood, are necessary for proper muscle guidance and attachment during development. In the present study, we used dorsal longitudinal muscles of Drosophila and their tendon attachment sites to unravel the molecular nature of interactions between muscles and tendons. We performed a genetic screen using RNAi-mediated knockdown in tendon cells to find out molecular players involved in the formation and maintenance of myotendinous junction and found 21 candidates out of 2507 RNAi lines screened. Of these, 19 were novel molecules in context of myotendinous system. Integrin-βPS and Talin, picked as candidates in this screen, are known to play important role in the cell-cell interaction and myotendinous junction formation validating our screen. We have found candidates with enzymatic function, transcription activity, cell adhesion, protein folding and intracellular transport function. Tango1, an ER exit protein involved in collagen secretion was identified as a candidate molecule involved in the formation of myotendinous junction. Tango1 knockdown was found to affect development of muscle attachment sites and formation of myotendinous junction. Tango1 was also found to be involved in secretion of Viking (Collagen type IV and BM-40 from hemocytes and fat cells.

  12. Bone healing response in cyclically loaded implants: Comparing zero, one, and two loading sessions per day.

    Science.gov (United States)

    de Barros E Lima Bueno, Renan; Dias, Ana Paula; Ponce, Katia J; Wazen, Rima; Brunski, John B; Nanci, Antonio

    2018-05-31

    When bone implants are loaded, they are inevitably subjected to displacement relative to bone. Such micromotion generates stress/strain states at the interface that can cause beneficial or detrimental sequels. The objective of this study is to better understand the mechanobiology of bone healing at the tissue-implant interface during repeated loading. Machined screw shaped Ti implants were placed in rat tibiae in a hole slightly bigger than the implant diameter. Implants were held stable by a specially-designed bone plate that permits controlled loading. Three loading regimens were applied, (a) zero loading, (b) one daily loading session of 60 cycles with an axial force of 1.5 N/cycle for 7 days, and (c) two such daily sessions with the same axial force also for 7 days. Finite element analysis was used to characterize the mechanobiological conditions produced by the loading sessions. After 7 days, the implants with surrounding interfacial tissue were harvested and processed for histological, histomorphometric and DNA microarray analyses. Histomorphometric analyses revealed that the group subjected to repeated loading sessions exhibited a significant decrease in bone-implant contact and increase in bone-implant distance, as compared to unloaded implants and those subjected to only one loading session. Gene expression profiles differed during osseointegration between all groups mainly with respect to inflammatory and unidentified gene categories. The results indicate that increasing the daily cyclic loading of implants induces deleterious changes in the bone healing response, most likely due to the accumulation of tissue damage and associated inflammatory reaction at the bone-implant interface. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.

  13. Simultaneous bilateral patellar tendon rupture.

    Science.gov (United States)

    Moura, Diogo Lino; Marques, José Pedro; Lucas, Francisco Manuel; Fonseca, Fernando Pereira

    2017-01-01

    Bilateral patellar tendon rupture is a rare entity, often associated with systemic diseases and patellar tendinopathy. The authors report a rare case of a 34-year-old man with simultaneous bilateral rupture of the patellar tendon caused by minor trauma. The patient is a retired basketball player with no past complaints of chronic knee pain and a history of steroid use. Surgical management consisted in primary end-to-end tendon repair protected temporarily with cerclage wiring, followed by a short immobilization period and intensive rehabilitation program. Five months after surgery, the patient was able to fully participate in sport activities.

  14. Wireless Impedance Sensor with PZT-Interface for Prestress-Loss Monitoring in Prestressed Concrete Girder

    International Nuclear Information System (INIS)

    Nguyen, Khac Duy; Lee, So Young; Kim, Jeong Tae

    2011-01-01

    Ensuring the designed prestress force is very important for the safety of prestressed concrete bridge. The loss of prestress force in tendon could significantly reduce load carrying capacity of the structure. In this study, an automated prestress-loss monitoring system for prestressed concrete girder using PZT-interface and wireless impedance sensor node is presented. The following approaches are carried out to achieve the objective. Firstly, wireless impedance sensor nodes are designed for automated impedance-based monitoring technique. The sensor node is mounted on the high-performance Imote2 sensor platform to fulfill high operating speed, low power requirement and large storage memory. Secondly, a smart PZT-interface designed for monitoring prestress force is described. A linear regression model is established to predict prestress-loss. Finally, a system of the PZT-interface interacted with the wireless sensor node is evaluated from a lab-scale tendon-anchorage connection of a prestressed concrete girder

  15. Effect of estrogen on tendon collagen synthesis, tendon structural characteristics, and biomechanical properties in postmenopausal women

    DEFF Research Database (Denmark)

    Hansen, Mette; Kongsgaard, Mads; Holm, Lars

    2009-01-01

    and fibril characteristics were determined by MRI and transmission electron microscopy, whereas tendon biomechanical properties were measured during isometric maximal voluntary contraction by ultrasound recording. Tendon FSR was markedly higher in ERT-users (P

  16. Ultraviolet photoelectron spectroscopy investigation of interface formation in an indium-tin oxide/fluorocarbon/organic semiconductor contact

    International Nuclear Information System (INIS)

    Tong, S.W.; Lau, K.M.; Sun, H.Y.; Fung, M.K.; Lee, C.S.; Lifshitz, Y.; Lee, S.T.

    2006-01-01

    It has been demonstrated that hole-injection in organic light-emitting devices (OLEDs) can be enhanced by inserting a UV-illuminated fluorocarbon (CF x ) layer between indium-tin oxide (ITO) and organic hole-transporting layer (HTL). In this work, the process of interface formation and electronic properties of the ITO/CF x /HTL interface were investigated with ultraviolet photoelectron spectroscopy. It was found that UV-illuminated fluorocarbon layer decreases the hole-injection barrier from ITO to α-napthylphenylbiphenyl diamine (NPB). Energy level diagrams deduced from the ultraviolet photoelectron spectroscopy (UPS) spectra show that the hole-injection barrier in ITO/UV-treated CF x /NPB is the smallest (0.46 eV), compared to that in the ITO/untreated CF x /NPB (0.60 eV) and the standard ITO/NPB interface (0.68 eV). The improved current density-voltage (I-V) characteristics in the UV-treated CF x -coated ITO contact are consistent with its smallest barrier height

  17. Investigations related to failure of prestressing tendons

    International Nuclear Information System (INIS)

    Boyadjiev, Z.

    1995-01-01

    Kozloduy NPP units 5 and 6 containment cladding shells are prestressed by the use of tendons 450 φ 5, made of high strength wires, class B-II. The prestressing force for each tendon is 10000 kN and the calculated breakdown force - 14000 kN. There are 96 tendons in the cylindrical part of the shell and 36 ones located in the containment dome. They are located in channel forming tubes of inner diameter of 200 mm, made of dense polyethylene. In order to assure biaxial prestressed condition, the prestressing tendons are located on screw shaped lines, both left and right, with declination to the horizon 35 degrees and 15 minutes. Each prestressing tendon initially forms a knee and following the bending at elevation + 10.80 m forms the other knee, in such a way, that its two ends are anchored in one and the same area-in a common or adjacent upper anchor boxes. The prestressing tendons in the containment dome are located in two perpendicular rows. Both ends of each tendon are anchored in a common fixing, the tendon being bent to the opposite side of the dome. During construction and operation of units 5 and 6, it was found, that the design prestressing force of 10000 kN can not be reached with some tendons, due to separate wires ruptures or due to the anchoring screw spent thread. The 1992 preliminary wires tests on a failed tendon found out deformation properties, different from the systematically obtained ones for the initial steel. Taking into consideration this fact, together with the IAEA regional project, concerning WWER-1000 seismic safety and items 4 and 6 of Kozloduy NPP Technical Council decisions of 10 June 1993, brought to delegation to the Research Construction Institute the performance of the technical analysis of the applied system for shell prestressing of containments of of units 5 and 6. The analysis comprises physical-mechanical and rheological properties of the high strength wires, used for containment shell prestressing and the over all technological

  18. Glutaraldehyde cross-linking of tendon mechanical effects at the level of the tendon fascicle and fibril

    DEFF Research Database (Denmark)

    Hansen, Philip; Hassenkam, Tue; Svensson, Rene Bruggebusch

    2009-01-01

    at the tendon fibril level were examined by atomic force microscopy. Peak forces increased from approximately 1379 to approximately 2622 pN while an extended Hertz fit of force-indentation data showed a approximately 24 fold increase in Young's modulus on indentation. The effect of glutaraldehyde cross......Conclusive insight into the microscopic principles that govern the strength of tendon and related connective tissues is lacking and the importance of collagen cross-linking has not been firmly established. The combined application of whole-tissue mechanical testing and atomic force spectroscopy...... allowed for a detailed characterization of the effect of cross-linking in rat-tail tendon. The cross-link inducing agent glutaraldehyde augmented the tensile strength of tendon fascicles. Stress at failure increased from approximately 8 MPa to approximately 39 MPa. The mechanical effects of glutaraldehyde...

  19. Clinical results of a surgical technique using endobuttons for complete tendon tear of pectoralis major muscle: report of five cases

    Directory of Open Access Journals (Sweden)

    Uchiyama Yoshiyasu

    2011-09-01

    Full Text Available Abstract Background We herein describe a surgical technique for the repair of complete tear of the pectoralis major (PM tendon using endobuttons to strengthen initial fixation. Methods Five male patients (3 judo players, 1 martial arts player, and 1 body builder were treated within 2 weeks of sustaining complete tear of the PM tendon. Average age at surgery and follow-up period were 28.4 years (range, 23-33 and 28.8 months (range, 24-36. A rectangular bone trough (about 1 × 4 cm was created on the humerus at the insertion of the distal PM tendon. The tendon stump was introduced into this trough, and fixed to the reverse side of the humeral cortex using endobuttons and non-absorbable suture. Clinical assessment of re-tear was examined by MRI. Shoulder range of motion (ROM, outcome of treatment, and isometric power were measured at final follow-up. Results There were no clinical re-tears, and MRI findings also showed continuity of the PM tendon in all cases at final follow-up. Average ROM did not differ significantly between the affected and unaffected shoulders. The clinical outcomes at final follow-up were excellent (4/5 cases or good (1/5. In addition, postoperative isometric power in horizontal flexion of the affected shoulder showed complete recovery when compared with the unaffected side. Conclusions Satisfactory outcomes could be obtained when surgery using the endobutton technique was performed within 2 weeks after complete tear of the PM tendon. Therefore, our new technique appears promising as a useful method to treat complete tear of the PM tendon.

  20. Numerical models for prestressing tendons in containment structures

    International Nuclear Information System (INIS)

    Kwak, Hyo-Gyoung; Kim, Jae Hong

    2006-01-01

    Two modified stress-strain relations for bonded and unbonded internal tendons are proposed. The proposed relations can simulate the post-cracking behavior and tension stiffening effect in prestressed concrete containment structures. In the case of the bonded tendon, tensile forces between adjacent cracks are transmitted from a bonded tendon to concrete by bond forces. Therefore, the constitutive law of a bonded tendon stiffened by grout needs to be determined from the bond-slip relationship. On the other hand, a stress increase beyond the effective prestress in an unbonded tendon is not section-dependent but member-dependent. It means that the tendon stress unequivocally represents a uniform distribution along the length when the friction loss is excluded. Thus, using a strain reduction factor, the modified stress-strain curve of an unbonded tendon is derived by successive iterations. In advance, the prediction of cracking behavior and ultimate resisting capacity of prestressed concrete containment structures using the introduced numerical models are succeeded, and the need for the consideration of many influencing factors such as the tension stiffening effect, plastic hinge length and modification of stress-strain relation of tendon is emphasized. Finally, the developed numerical models are applied to prestressed concrete containment structures to verify the efficiency and applicability in simulating the structural behavior with bonded and/or unbonded tendons

  1. THE ROLE OF DETRAINING IN TENDON MECHANOBIOLOGY

    Directory of Open Access Journals (Sweden)

    Antonio eFrizziero

    2016-02-01

    Full Text Available Introduction: Several conditions such as training, aging, estrogen deficiency and drugs could affect the biological and anatomo-physiological characteristics of the tendon. Additionally, recent preclinical and clinical studies examined the effect of detraining on tendon, showing alterations in its structure and morphology and in tenocyte mechanobiology. However, there is a paucity of data examining the impact that cessation of training may have on tendon. In practice, we do not fully understand how tendons respond to a period of training followed by sudden detraining. Therefore, within this review, we summarize the studies where tendon detraining was examined.Materials and methods: A descriptive systematic literature review was conducted by searching three databases (PubMed, Scopus and Web of Knowledge on tendon detraining. Original articles in English from 2000 to 2015 were included. In addition, the search was extended to the reference lists of the selected articles. A public reference manager (www.mendeley.com was used to delete duplicate articles.Results: An initial literature search yielded 134 references (www.pubmed.org: 53; www.scopus.com: 11; www.webofknowledge.com: 70. 15 publications were extracted based on the title for further analysis by two independent reviewers. Abstracts and whole articles were then reviewed to detect if they met inclusion criteria.Conclusions: The revised literature comprised 4 clinical studies and an in vitro and three in vivo reports. Overall, the results showed that tendon structure and properties after detraining are compromised, with an alteration in the tissue structural organization and mechanical properties. Clinical studies usually showed a lesser extent of tendon alterations, probably because preclinical studies permit an in-depth evaluation of tendon modifications, which is hard to perform in human subjects. In conclusion, after a period of sudden detraining (e.g. after an injury, physical activity

  2. Ascending infection of foot tendons in diabetic patients.

    Science.gov (United States)

    Mismar, Ayman; Yousef, Mohammad; Badran, Darwish; Younes, Nidal

    2013-12-01

    Bone and soft tissue infection in the foot of diabetic patients is a well-described issue in the literature. A sound anatomical knowledge of the foot anatomy and compartments is mandatory to understand the mechanisms of infection spread. We describe four cases of diabetic foot infection complicated by long ascending infection. All did not respond initially to antibiotic treatment and the usual surgical debridement and were cured only after excision of the infected tendons. We highlight a rare but serious complication of the diabetic foot disease not commonly seen by the surgical community. We hope that this report raises the awareness of this condition so that a prompt diagnosis is made and appropriate treatment started, thereby reducing the risk of major lower limb amputations.

  3. Local trauma in human patellar tendon leads to widespread changes in the tendon gene expression

    DEFF Research Database (Denmark)

    Heinemeier, Katja Maria; Lorentzen, Marc P; Kildevang Jensen, Jacob

    2016-01-01

    Low cellular activity and slow tissue turnover in human tendon may prolong resolution of tendinopathy. This may be stimulated by moderate localized traumas such as needle penetrations, but whether this results in a widespread cellular response in tendons is unknown. In an initial hypothesis-gener...

  4. Influence of bone marrow on osseointegration in long bones: an experimental study in sheep.

    Science.gov (United States)

    Morelli, Fabrizio; Lang, Niklaus P; Bengazi, Franco; Baffone, Davide; Vila Morales, C Dadonim; Botticelli, Daniele

    2015-03-01

    To evaluate the influence of yellow bone marrow on osseointegration of titanium oral implants using a long bone model. The two tibiae of eight sheep were used as experimental sites. Two osteotomies for implant installation were prepared in each tibia. At the control sites, no further treatments were performed while, at the test sites, bone marrow was removed from the osteotomy site with a curette to an extent that exceeded the implant dimensions. As a result, the apical portion of the implants at the control sites was in contact with bone marrow while, at the test sites, it was in contact with the blood clot. After 2 months, the same procedures were performed in the contralateral side. After another month, the animal was sacrificed. Ground sections were obtained for histological analysis. After 1 month of healing, no differences between test and control sites were found in the apical extension of osseointegration and the percentage of new bone-to-implant contact. However, after 3 months of healing, a higher percentage of new bone-to-implant contact was found at the test compared to the control sites in the marrow compartment. The apical extension of osseointegration, however, was similar to that found at the 1-month healing period both for test and control sites. Osseointegration appeared to be favored by the presence of a blood clot when compared to the presence of yellow fatty bone marrow. Moreover, the contact with cortical bone appeared to be a prerequisite for the osseointegration process in the long bone model. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  5. Tendon overuse syndrome: imaging diagnosis

    International Nuclear Information System (INIS)

    Huber, W.; Nehrer, S.; Muellner, T.; Kainberger, F.; Ulreich, N.; Bernhard, C.; Imhof, H.

    2001-01-01

    Injuries of muscles and tendons occur commonly during various sporting activities and in most cases the athletes feel such an accident to be sudden and unavoidable. The rupture of a tendon, however, has to be considered in many cases as the final stage of a long-standing progressive degeneration of collagen fibers. This process con be described as 'tendon overuse syndrome (TOS)'. Diagnostic imaging modalities, especially sonography and MRI, are suitable to detect and analyse the different stages of this syndrome and the degree of morphological abnormalities. The first stage is painful functional derangement, followed by tendovaginitis, peritendinitis, or bursitis. The third stage is tendinosis resulting from biomechanical or ischaemic injury of tendon fibers which may eventually be followed by partial or complete rupture. Regional or individual specifications of these four stages may occur at anatomically predisposing sites, so-called critical zones, or during periods of specific proneness, the vulnerable phases. (author)

  6. Robot Arm with Tendon Connector Plate and Linear Actuator

    Science.gov (United States)

    Ihrke, Chris A. (Inventor); Diftler, Myron A. (Inventor); Bridgwater, Lyndon (Inventor); Nguyen, Vienny (Inventor); Millerman, Alexander (Inventor)

    2014-01-01

    A robotic system includes a tendon-driven end effector, a linear actuator, a flexible tendon, and a plate assembly. The linear actuator assembly has a servo motor and a drive mechanism, the latter of which translates linearly with respect to a drive axis of the servo motor in response to output torque from the servo motor. The tendon connects to the end effector and drive mechanism. The plate assembly is disposed between the linear actuator assembly and the tendon-driven end effector and includes first and second plates. The first plate has a first side that defines a boss with a center opening. The second plate defines an accurate through-slot having tendon guide channels. The first plate defines a through passage for the tendon between the center opening and a second side of the first plate. A looped end of the flexible tendon is received within the tendon guide channels.

  7. [Flexor tendon repair: a short story].

    Science.gov (United States)

    Moutet, F; Corcella, D; Forli, A; Mesquida, V

    2014-12-01

    This short story of flexor tendon repair aims to illustrate hesitations and wanderings of this surgery. Obviously tendon repair was very early considered, but it developed and diffused rather lately. It became a routine practice only in 20th century. This was due on the one hand, in Occident, to the Galen's dogmatic interdiction, on the other hand, to the repair difficulties of this paradoxical structure. Actually tendon is made of fibroblasts and collagen (sticky substances), and then its only goal is to move. According to this necessity, whatever the used techniques are, gliding is the final purpose. Technical evolutions are illustrated by historical contributions to flexor tendon surgery of several "giants" of hand surgery. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  8. Clinical results of arthroscopic polyglycolic acid sheet patch graft for irreparable rotator cuff tears

    Directory of Open Access Journals (Sweden)

    Yu Mochizuki

    2015-01-01

    Full Text Available The high retear rates after surgery for irreparable rotator cuff tears can be explained by the healing capacity potential of tendons and the native rotator cuff enthesis characterised by complex morphological structures, called direct insertion. Many experimental researches have focused on biologically augmenting the rotator cuff reconstruction and improving tendon–bone healing of the rotator cuff. The results of the experimental study showed that the polyglycolic acid sheet scaffold material allows for the regeneration of not only tendon-to-tendon, but also tendon-to-bone interface in an animal model. We performed a clinical study of the arthroscopic polyglycolic acid sheet patch graft used for the repair of irreparable rotator cuff tears. One-year clinical results of the repair of irreparable rotator cuff tears by arthroscopic patch graft with a polyglycolic acid sheet demonstrated improved shoulder function and a significantly lower retear rate, compared with patients treated with a fascia lata patch.

  9. [Posterior tibial tendon dysfunction: what other structures are involved in the development of acquired adult flat foot?].

    Science.gov (United States)

    Herráiz Hidalgo, L; Carrascoso Arranz, J; Recio Rodríguez, M; Jiménez de la Peña, M; Cano Alonso, R; Álvarez Moreno, E; Martínez de Vega Fernández, V

    2014-01-01

    To evaluate the association of posterior tibial tendon dysfunction and lesions of diverse ankle structures diagnosed at MRI with radiologic signs of flat foot. We retrospectively compared 29 patients that had posterior tibial tendon dysfunction (all 29 studied with MRI and 21 also studied with weight-bearing plain-film X-rays) with a control group of 28 patients randomly selected from among all patients who underwent MRI and weight-bearing plain-film X-rays for other ankle problems. In the MRI studies, we analyzed whether a calcaneal spur, talar beak, plantar fasciitis, calcaneal bone edema, Achilles' tendinopathy, spring ligament injury, tarsal sinus disease, and tarsal coalition were present. In the weight-bearing plain-film X-rays, we analyzed the angle of Costa-Bertani and radiologic signs of flat foot. To analyze the differences between groups, we used Fisher's exact test for the MRI findings and for the presence of flat foot and analysis of variance for the angle of Costa-Bertani. Calcaneal spurs, talar beaks, tarsal sinus disease, and spring ligament injury were significantly more common in the group with posterior tibial tendon dysfunction (P<.05). Radiologic signs of flat foot and anomalous values for the angle of Costa-Bertani were also significantly more common in the group with posterior tibial tendon dysfunction (P<.001). We corroborate the association between posterior tibial tendon dysfunction and lesions to the structures analyzed and radiologic signs of flat foot. Knowledge of this association can be useful in reaching an accurate diagnosis. Copyright © 2011 SERAM. Published by Elsevier Espana. All rights reserved.

  10. Comprehensive evaluation of finger flexor tendon entheseal soft tissue and bone changes by ultrasound can differentiate psoriatic arthritis and rheumatoid arthritis.

    Science.gov (United States)

    Tinazzi, Ilaria; McGonagle, Dennis; Zabotti, Alen; Chessa, Donatella; Marchetta, Antonio; Macchioni, Pierluigi

    2018-02-28

    To determine whether a detailed sonographic evaluation of the hand flexor tendon compartment could help differentiate between psoriatic arthritis (PsA) and rheumatoid arthritis (RA). Thirty-seven patients with PsA, 47 with RA and 10 healthy controls (HC) had flexor tendon (FT) compartment imaging of the dominant hand 2nd to 4th tendons using grey scale (GS) and power Doppler (PD) ultrasound (US) with evaluation for tenosynovitis, peri-tendinous lesions, soft tissue oedema and bony changes at FT insertions. 24/37 PsA and 19/47 RA cases had morning stiffness and 19/37 PsA and 10/47 RA had swollen and/or tender fingers. Tenosynovitis was more common in PsA (25/37) despite higher DAS28 scores in RA (25/37 versus 10/45; pthe insertional site was significantly more common in PsA (p=0.001). Considering a total inflammatory score per patient summing up the three modifications of the flexor tendon (tenosynovitis, peri-tendinous oedema and insertional enthesophytes) the difference between PsA and RA remained statistically significant (pthe growing body of literature that high resolution US of the hand FT compartment may help differentiate between RA and PsA, which needs assessment in the diagnostic setting.

  11. Synthesis of embryonic tendon-like tissue by human marrow stromal/mesenchymal stem cells requires a three-dimensional environment and transforming growth factor β3.

    Science.gov (United States)

    Kapacee, Zoher; Yeung, Ching-Yan Chloé; Lu, Yinhui; Crabtree, David; Holmes, David F; Kadler, Karl E

    2010-10-01

    Tendon-like tissue generated from stem cells in vitro has the potential to replace tendons and ligaments lost through injury and disease. However, thus far, no information has been available on the mechanism of tendon formation in vitro and how to accelerate the process. We show here that human mesenchymal stem cells (MSCs) and bone marrow-derived mononuclear cells (BM-MNCs) can generate tendon-like tissue in 7days mediated by transforming growth factor (TGF) β3. MSCs cultured in fixed-length fibrin gels spontaneously synthesized narrow-diameter collagen fibrils and exhibited fibripositors (actin-rich, collagen fibril-containing plasma membrane protrusions) identical to those that occur in embryonic tendon. In contrast, BM-MNCs did not synthesize tendon-like tissue under these conditions. We performed real-time PCR analysis of MSCs and BM-MNCs. MSCs upregulated genes encoding type I collagen, TGFβ3, and Smad2 at the time of maximum contraction of the tendon-like tissue (7days). Western blot analysis showed phosphorylation of Smad2 at maximum contraction. The TGFβ inhibitor SB-431542, blocked the phosphorylation of Smad2 and stopped the formation of tendon-like tissue. Quantitative PCR showed that BM-MNCs expressed very low levels of TGFβ3 compared to MSCs. Therefore we added exogenous TGFβ3 protein to BM-MNCs in fibrin gels, which resulted in phosphorylation of Smad2, synthesis of collagen fibrils, the appearance of fibripositors at the plasma membrane, and the formation of tendon-like tissue. In conclusion, MSCs that self-generate TGFβ signaling or the addition of TGFβ3 protein to BM-MNCs in fixed-length fibrin gels spontaneously make embryonic tendon-like tissue in vitro within 7days. Copyright © 2010 International Society of Matrix Biology. Published by Elsevier B.V. All rights reserved.

  12. Shortened stapedius tendon: a rare cause of conductive hearing loss.

    Science.gov (United States)

    Zawawi, F; Varshney, R; Schloss, M D

    2014-01-01

    Anomalies of the stapedius tendon have been reported to cause conductive hearing loss; in theory, such anomalies limit the movement of the stapes. To demonstrate a rare cause of conductive hearing loss resulting from anomaly of the stapedius tendon and to compare the clinical findings of this patient to other stapedius tendon anomalies reported in the literature. Case report of a single case of shortened stapedius tendon and a review of the English literature on stapedius tendon anomalies. This is a case report of a 15-year-old boy with shortened stapedius tendon causing unilateral hearing loss, accompanied by a review of the literature. Contrary to other reported cases, this patient did not have an ossified tendon, but rather an extremely short tendon. The boy regained normal hearing following excision of the stapedius tendon. A shortened stapedius tendon is a very rare diagnosis, yet it should be considered as a possible cause of conductive hearing loss.

  13. Accuracy of MRI technique in measuring tendon cross-sectional area

    DEFF Research Database (Denmark)

    Couppé, Christian; Svensson, R. B.; Elbrønd (Bibs), Vibeke Sødring

    2014-01-01

    , but the accuracy in relation to actual tendon dimensions has never been investigated. The purpose of this study was to compare tendon CSA measured by MRI with that measured in vitro with the mould casting technique. The knee of a horse was MRI-scanned with 1.5 and 3 tesla, and two examiners measured the patellar...... tendon CSA. Thereafter, the patellar tendon of the horse was completely dissected and embedded in an alginate cast. The CSA of the embedded tendon was measured directly by optical imaging of the cast impression. 1.5 tesla grey tendon CSA and 3 tesla grey tendon CSA were 16.5% and 13.2% lower than...... the mould tendon CSA, respectively. Also, 3 tesla tendon CSA, based on the red-green border on the National Institute of Health (NIH) colour scale, was lower than the mould tendon CSA by 2.8%. The typical error between examiners was below 2% for all the measured CSA. The typical error between examiners...

  14. The blood-tendon barrier: identification and characterisation of a novel tissue barrier in tendon blood vessels

    Directory of Open Access Journals (Sweden)

    C Lehner

    2016-05-01

    Full Text Available Tissue barriers function as “gate keepers” between different compartments (usually blood and tissue and are formed by specialised membrane-associated proteins, localising to the apicolateral plasma membrane domain of epithelial and endothelial cells. By sealing the paracellular space, the free diffusion of solutes and molecules across epithelia and endothelia is impeded. Thereby, tissue barriers contribute to the establishment and maintenance of a distinct internal and external environment, which is crucial during organ development and allows maintenance of an organ-specific homeostatic milieu. So far, various epithelial and endothelial tissue barriers have been described, including the blood-brain barrier, the blood-retina barrier, the blood-testis barrier, the blood-placenta barrier, and the cerebrospinal fluid (CSF-brain barrier, which are vital for physiological function and any disturbance of these barriers can result in severe organ damage or even death. Here, we describe the identification of a novel barrier, located in the vascular bed of tendons, which we term the blood-tendon barrier (BTB. By using immunohistochemistry, transmission electron microscopy, and tracer studies we demonstrate the presence of a functional endothelial barrier within tendons restricting the passage of large blood-borne molecules into the surrounding tendon tissue. We further provide in vitro evidence that the BTB potentially contributes to the creation of a distinct internal tissue environment impacting upon the proliferation and differentiation of tendon-resident cells, effects which might be fundamental for the onset of tendon pathologies.

  15. p38 MAPK signaling in postnatal tendon growth and remodeling.

    Directory of Open Access Journals (Sweden)

    Andrew J Schwartz

    Full Text Available Tendon is a dynamic tissue whose structure and function is influenced by mechanical loading, but little is known about the fundamental mechanisms that regulate tendon growth and remodeling in vivo. Data from cultured tendon fibroblasts indicated that the p38 MAPK pathway plays an important role in tendon fibroblast proliferation and collagen synthesis in vitro. To gain greater insight into the mechanisms of tendon growth, and explore the role of p38 MAPK signaling in this process, we tested the hypotheses that inducing plantaris tendon growth through the ablation of the synergist Achilles tendon would result in rapid expansion of a neotendon matrix surrounding the original tendon, and that treatment with the p38 MAPK inhibitor SB203580 would prevent this growth. Rats were treated with vehicle or SB203580, and subjected to synergist ablation by bilateral tenectomy of the Achilles tendon. Changes in histological and biochemical properties of plantaris tendons were analyzed 3, 7, or 28 days after overload, and comparisons were made to non-overloaded animals. By 28 days after overload, tendon mass had increased by 30% compared to non-overloaded samples, and cross-sectional area (CSA increased by around 50%, with most of the change occurring in the neotendon. The expansion in CSA initially occurred through the synthesis of a hyaluronic acid rich matrix that was progressively replaced with mature collagen. Pericytes were present in areas of active tendon growth, but never in the original tendon ECM. Inhibition of p38 MAPK resulted in a profound decrease in IL6 expression, and had a modest effect on the expression of other ECM and cell proliferation genes, but had a negligible impact on overall tendon growth. The combined results from this study provided novel insights into tendon mechanobiology, and suggest that p38 MAPK signaling does not appear to be necessary for tendon growth in vivo.

  16. Beneficial Effects of Autologous Bone Marrow-Derived Mesenchymal Stem Cells in Naturally Occurring Tendinopathy

    Science.gov (United States)

    Smith, Roger Kenneth Whealands; Werling, Natalie Jayne; Dakin, Stephanie Georgina; Alam, Rafiqul; Goodship, Allen E.; Dudhia, Jayesh

    2013-01-01

    Tendon injuries are a common age-related degenerative condition where current treatment strategies fail to restore functionality and normal quality of life. This disease also occurs naturally in horses, with many similarities to human tendinopathy making it an ideal large animal model for human disease. Regenerative approaches are increasingly used to improve outcome involving mesenchymal stem cells (MSCs), supported by clinical data where injection of autologous bone marrow derived MSCs (BM-MSCs) suspended in marrow supernatant into injured tendons has halved the re-injury rate in racehorses. We hypothesized that stem cell therapy induces a matrix more closely resembling normal tendon than the fibrous scar tissue formed by natural repair. Twelve horses with career-ending naturally-occurring superficial digital flexor tendon injury were allocated randomly to treatment and control groups. 1X107 autologous BM-MSCs suspended in 2 ml of marrow supernatant were implanted into the damaged tendon of the treated group. The control group received the same volume of saline. Following a 6 month exercise programme horses were euthanized and tendons assessed for structural stiffness by non-destructive mechanical testing and for morphological and molecular composition. BM-MSC treated tendons exhibited statistically significant improvements in key parameters compared to saline-injected control tendons towards that of normal tendons and those in the contralateral limbs. Specifically, treated tendons had lower structural stiffness (ptendon repair in enhancing normalisation of biomechanical, morphological, and compositional parameters. These data in natural disease, with no adverse findings, support the use of this treatment for human tendon injuries. PMID:24086616

  17. Histological Observation of Regions around Bone Tunnels after Compression of the Bone Tunnel Wall in Ligament Reconstruction

    International Nuclear Information System (INIS)

    Maeda, Shintaro; Ishikawa, Hiroki; Tanigawa, Naoaki; Miyazaki, Kyosuke; Shioda, Seiji

    2012-01-01

    The objectives of this study were to investigate the time-course of influence of compression of bone tunnel wall in ligament reconstruction on tissue around the bone tunnel and to histologically examine the mechanism of preventing the complication of bone tunnel dilation, using rabbit tibia. A model in which the femoral origin of the extensor digitorum longus tendon was cut and inserted into a bone tunnel made proximal to the tibia was prepared in the bilateral hind legs of 20 Japanese white rabbits. In each animal, a tunnel was made using a drill only in the right leg, while an undersized bone tunnel was made by drilling and then dilated by compression using a dilator to the same tunnel size as that in the right leg. Animals were sacrificed at 0, 2, 4, 8 and 12 weeks after surgery (4 animals at each time point). Observation of bone tunnels by X-ray radiography showed osteosclerosis in the 2- and 4-week dilation groups. Osteosclerosis appeared as white lines around the bone tunnel on X-ray radiography. This suggests that dilation promotes callus formation in the bone tunnel wall and prevents the complication of bone tunnel enlargement after ligament reconstruction

  18. Glutaraldehyde Cross-Linking of TendonMechanical Effects at the Level of the Tendon Fascicle and Fibril

    DEFF Research Database (Denmark)

    Hansen, P.; Svensson, R.B.; Aagaard, P.

    2009-01-01

    were examined by atomic force microscopy. Peak forces increased from 1379 to 2622 pN while an extended Hertz fit of force-indentation data showed a 24 fold increase in Young's modulus on indentation. The effect of glutaraldehyde cross-linking on the tensile properties of a single collagen fibril......Conclusive insight into the microscopic principles that govern the strength of tendon and related connective tissues is lacking and the importance of collagen cross-linking has not been firmly established. The combined application of whole-tissue mechanical testing and atomic force spectroscopy...... allowed for a detailed characterization of the effect of cross-linking in rat-tail tendon. The cross-link inducing agent glutaraldehyde augmented the tensile strength of tendon fascicles. Stress at failure increased from 8 MPa to 39 MPa. The mechanical effects of glutaraldehyde at the tendon fibril level...

  19. Pathophysiology of overuse tendon injury

    International Nuclear Information System (INIS)

    Kannus, P.; Paavola, M.; Paakkala, T.; Parkkari, J.; Jaervinen, T.; Jaervinen, M.

    2002-01-01

    Overuse tendon injury is one of the most common injuries in sports.The etiology as well as the pathophysilogical mechanisms leading to tendinopathy are of crucial medical importance.At the moment intrinsic and extrinsic factors are assumed as mechanisms of overuse tendon injury. Except for the acute, extrinsic trauma, the chronic overuse tendon injury is a multifactorial process. There are many other factors, such as local hypoxia, less of nutrition, impaired metabolism and local inflammatory that may also contribute to the development of tissue damage.The exact interaction of these factors cannot be explained entirely at the moment.Further studies will be necessary in order to get more information. (orig.) [de

  20. Simultaneous bilateral patellar tendon rupture

    Directory of Open Access Journals (Sweden)

    Diogo Lino Moura

    Full Text Available ABSTRACT Bilateral patellar tendon rupture is a rare entity, often associated with systemic diseases and patellar tendinopathy. The authors report a rare case of a 34-year-old man with simultaneous bilateral rupture of the patellar tendon caused by minor trauma. The patient is a retired basketball player with no past complaints of chronic knee pain and a history of steroid use. Surgical management consisted in primary end-to-end tendon repair protected temporarily with cerclage wiring, followed by a short immobilization period and intensive rehabilitation program. Five months after surgery, the patient was able to fully participate in sport activities.

  1. Rotator cuff tendon connections with the rotator cable.

    Science.gov (United States)

    Rahu, Madis; Kolts, Ivo; Põldoja, Elle; Kask, Kristo

    2017-07-01

    The literature currently contains no descriptions of the rotator cuff tendons, which also describes in relation to the presence and characteristics of the rotator cable (anatomically known as the ligamentum semicirculare humeri). The aim of the current study was to elucidate the detailed anatomy of the rotator cuff tendons in association with the rotator cable. Anatomic dissection was performed on 21 fresh-frozen shoulder specimens with an average age of 68 years. The rotator cuff tendons were dissected from each other and from the glenohumeral joint capsule, and the superior glenohumeral, coracohumeral, coracoglenoidal and semicircular (rotator cable) ligaments were dissected. Dissection was performed layer by layer and from the bursal side to the joint. All ligaments and tendons were dissected in fine detail. The rotator cable was found in all specimens. It was tightly connected to the supraspinatus (SSP) tendon, which was partly covered by the infraspinatus (ISP) tendon. The posterior insertion area of the rotator cable was located in the region between the middle and inferior facets of the greater tubercle of the humerus insertion areas for the teres minor (TM), and ISP tendons were also present and fibres from the SSP extended through the rotator cable to those areas. The connection between the rotator cable and rotator cuff tendons is tight and confirms the suspension bridge theory for rotator cuff tears in most areas between the SSP tendons and rotator cable. In its posterior insertion area, the rotator cable is a connecting structure between the TM, ISP and SSP tendons. These findings might explain why some patients with relatively large rotator cuff tears can maintain seamless shoulder function.

  2. Primary clear cell sarcoma of bone

    International Nuclear Information System (INIS)

    Choi, J.H.; Gu, M.J.; Kim, M.J.; Bae, Y.K.; Choi, W.H.; Shin, D.S.; Cho, K.H.

    2003-01-01

    Clear cell sarcoma is a rare soft tissue sarcoma of young adults with melanocytic differentiation. It occurs predominantly in the soft tissue of extremities, typically involving tendons and aponeuroses. Primary clear cell sarcoma of bone is extremely rare. We report a case of primary clear cell sarcoma of the right first metatarsal in a 48-year-old woman and provide a literature review of the entity. (orig.)

  3. How the charge-neutrality level of interface states controls energy level alignment in cathode contacts of organic bulk-heterojunction solar cells.

    Science.gov (United States)

    Guerrero, Antonio; Marchesi, Luís F; Boix, Pablo P; Ruiz-Raga, Sonia; Ripolles-Sanchis, Teresa; Garcia-Belmonte, Germà; Bisquert, Juan

    2012-04-24

    Electronic equilibration at the metal-organic interface, leading to equalization of the Fermi levels, is a key process in organic optoelectronic devices. How the energy levels are set across the interface determines carrier extraction at the contact and also limits the achievable open-circuit voltage under illumination. Here, we report an extensive investigation of the cathode energy equilibration of organic bulk-heterojunction solar cells. We show that the potential to balance the mismatch between the cathode metal and the organic layer Fermi levels is divided into two contributions: spatially extended band bending in the organic bulk and voltage drop at the interface dipole layer caused by a net charge transfer. We scan the operation of the cathode under a varied set of conditions, using metals of different work functions in the range of ∼2 eV, different fullerene acceptors, and several cathode interlayers. The measurements allow us to locate the charge-neutrality level within the interface density of sates and calculate the corresponding dipole layer strength. The dipole layer withstands a large part of the total Fermi level mismatch when the polymer:fullerene blend ratio approaches ∼1:1, producing the practical alignment between the metal Fermi level and the charge-neutrality level. Origin of the interface states is linked with fullerene reduced molecules covering the metal contact. The dipole contribution, and consequently the band bending, is highly sensitive to the nature and amount of fullerene molecules forming the interface density of states. Our analysis provides a detailed picture of the evolution of the potentials in the bulk and the interface of the solar cell when forward voltage is applied or when photogeneration takes place.

  4. Elastic contact mechanics: percolation of the contact area and fluid squeeze-out.

    Science.gov (United States)

    Persson, B N J; Prodanov, N; Krick, B A; Rodriguez, N; Mulakaluri, N; Sawyer, W G; Mangiagalli, P

    2012-01-01

    The dynamics of fluid flow at the interface between elastic solids with rough surfaces depends sensitively on the area of real contact, in particular close to the percolation threshold, where an irregular network of narrow flow channels prevails. In this paper, numerical simulation and experimental results for the contact between elastic solids with isotropic and anisotropic surface roughness are compared with the predictions of a theory based on the Persson contact mechanics theory and the Bruggeman effective medium theory. The theory predictions are in good agreement with the experimental and numerical simulation results and the (small) deviation can be understood as a finite-size effect. The fluid squeeze-out at the interface between elastic solids with randomly rough surfaces is studied. We present results for such high contact pressures that the area of real contact percolates, giving rise to sealed-off domains with pressurized fluid at the interface. The theoretical predictions are compared to experimental data for a simple model system (a rubber block squeezed against a flat glass plate), and for prefilled syringes, where the rubber plunger stopper is lubricated by a high-viscosity silicon oil to ensure functionality of the delivery device. For the latter system we compare the breakloose (or static) friction, as a function of the time of stationary contact, to the theory prediction.

  5. Controlling interface oxygen for forming Ag ohmic contact to semi-polar (1 1 -2 2) plane p-type GaN

    Science.gov (United States)

    Park, Jae-Seong; Han, Jaecheon; Seong, Tae-Yeon

    2014-11-01

    Low-resistance Ag ohmic contacts to semi-polar (1 1 -2 2) p-GaN were developed by controlling interfacial oxide using a Zn layer. The 300 °C-annealed Zn/Ag samples showed ohmic behavior with a contact resistivity of 6.0 × 10-4 Ω cm2 better than that of Ag-only contacts (1.0 × 10-3 Ω cm2). The X-ray photoemission spectroscopy (XPS) results showed that annealing caused the indiffusion of oxygen at the contact/GaN interface, resulting in the formation of different types of interfacial oxides, viz. Ga-oxide and Ga-doped ZnO. Based on the XPS and electrical results, the possible mechanisms underlying the improved electrical properties of the Zn/Ag samples are discussed.

  6. Uncovering the cellular and molecular changes in tendon stem/progenitor cells attributed to tendon aging and degeneration.

    Science.gov (United States)

    Kohler, Julia; Popov, Cvetan; Klotz, Barbara; Alberton, Paolo; Prall, Wolf Christian; Haasters, Florian; Müller-Deubert, Sigrid; Ebert, Regina; Klein-Hitpass, Ludger; Jakob, Franz; Schieker, Matthias; Docheva, Denitsa

    2013-12-01

    Although the link between altered stem cell properties and tissue aging has been recognized, the molecular and cellular processes of tendon aging have not been elucidated. As tendons contain stem/progenitor cells (TSPC), we investigated whether the molecular and cellular attributes of TSPC alter during tendon aging and degeneration. Comparing TSPC derived from young/healthy (Y-TSPC) and aged/degenerated human Achilles tendon biopsies (A-TSPC), we observed that A-TSPC exhibit a profound self-renewal and clonogenic deficits, while their multipotency was still retained. Senescence analysis showed a premature entry into senescence of the A-TSPC, a finding accompanied by an upregulation of p16(INK4A). To identify age-related molecular factors, we performed microarray and gene ontology analyses. These analyses revealed an intriguing transcriptomal shift in A-TSPC, where the most differentially expressed probesets encode for genes regulating cell adhesion, migration, and actin cytoskeleton. Time-lapse analysis showed that A-TSPC exhibit decelerated motion and delayed wound closure concomitant to a higher actin stress fiber content and a slower turnover of actin filaments. Lastly, based on the expression analyses of microarray candidates, we suggest that dysregulated cell-matrix interactions and the ROCK kinase pathway might be key players in TSPC aging. Taken together, we propose that during tendon aging and degeneration, the TSPC pool is becoming exhausted in terms of size and functional fitness. Thus, our study provides the first fundamental basis for further exploration into the molecular mechanisms behind tendon aging and degeneration as well as for the selection of novel tendon-specific therapeutical targets. © 2013 The Authors. Aging Cell published by the Anatomical Society and John Wiley & Sons Ltd.

  7. 2D FEA of evaluation of micromovements and stresses at bone-implant interface in immediately loaded tapered implants in the posterior maxilla

    Directory of Open Access Journals (Sweden)

    Shrikar R Desai

    2013-01-01

    Full Text Available Aim: The aim of the study is to evaluate the influence implant length on stress distribution at bone implant interface in single immediately loaded implants when placed in D4 bone quality. Materials and Methods: A 2-dimensional finite element models were developed to simulate two types of implant designs, standard 3.75 mm-diameter tapered body implants of 6 and 10 mm lengths. The implants were placed in D4 bone quality with a cortical bone thickness of 0.5 mm. The implant design incorporated microthreads at the crestal part and the rest of the implant body incorporated Acme threads. The Acme thread form has a 29° thread angle with a thread height half of the pitch; the apex and valley are flat. A 100 N of force was applied vertically and in the oblique direction (at an angle of 45° to the long axis of the implants. The respective material properties were assigned. Micro-movements and stresses at the bone implant interface were evaluated. Results: The results of total deformation (micro-movement and Von mises stress were found to be lower for tapered long implant (10 mm than short implant (6 mm while using both vertical as well as oblique loading. Conclusion: Short implants can be successfully placed in poor bone quality under immediate loading protocol. The novel approach of the combination of microthreads at the crestal portion and acme threads for body portion of implant fixture gave promising results.

  8. 2D FEA of evaluation of micromovements and stresses at bone-implant interface in immediately loaded tapered implants in the posterior maxilla.

    Science.gov (United States)

    Desai, Shrikar R; Singh, Rika; Karthikeyan, I

    2013-09-01

    The aim of the study is to evaluate the influence implant length on stress distribution at bone implant interface in single immediately loaded implants when placed in D4 bone quality. A 2-dimensional finite element models were developed to simulate two types of implant designs, standard 3.75 mm-diameter tapered body implants of 6 and 10 mm lengths. The implants were placed in D4 bone quality with a cortical bone thickness of 0.5 mm. The implant design incorporated microthreads at the crestal part and the rest of the implant body incorporated Acme threads. The Acme thread form has a 29° thread angle with a thread height half of the pitch; the apex and valley are flat. A 100 N of force was applied vertically and in the oblique direction (at an angle of 45°) to the long axis of the implants. The respective material properties were assigned. Micro-movements and stresses at the bone implant interface were evaluated. The results of total deformation (micro-movement) and Von mises stress were found to be lower for tapered long implant (10 mm) than short implant (6 mm) while using both vertical as well as oblique loading. Short implants can be successfully placed in poor bone quality under immediate loading protocol. The novel approach of the combination of microthreads at the crestal portion and acme threads for body portion of implant fixture gave promising results.

  9. Subchondral bone in osteoarthritis: insight into risk factors and microstructural changes

    OpenAIRE

    Li, Guangyi; Yin, Jimin; Gao, Junjie; Cheng, Tak S; Pavlos, Nathan J; Zhang, Changqing; Zheng, Ming H

    2013-01-01

    Osteoarthritis (OA) is a major cause of disability in the adult population. As a progressive degenerative joint disorder, OA is characterized by cartilage damage, changes in the subchondral bone, osteophyte formation, muscle weakness, and inflammation of the synovium tissue and tendon. Although OA has long been viewed as a primary disorder of articular cartilage, subchondral bone is attracting increasing attention. It is commonly reported to play a vital role in the pathogenesis of OA. Subcho...

  10. Variation in the insertion of the palmaris longus tendon

    Science.gov (United States)

    Sunil, Vinutha; Rajanna, Shubha; Gitanjali; Kadaba, Jayanthi

    2015-01-01

    The palmaris longus is harvested as a tendon graft in various surgical procedures. We herein report the variations in the insertion of the palmaris longus tendon. During a routine dissection, a rare variation in the insertion of the palmaris longus tendon was observed. In the left forearm, the palmaris longus tendon bifurcated, while in the right forearm, the palmaris longus tendon trifurcated, giving rise to an accessory muscle, which passed superficial to the ulnar artery and ulnar nerve. The accessory muscle was supplied by a deep branch of the ulnar nerve, and the ulnar artery was observed to be tortuous. During reconstructive surgeries, surgeons should bear in mind the accessory muscle. Also, since the palmaris longus muscle provides a very useful graft in tendon surgery, every surgeon should be aware of the variations in the insertion of the palmaris longus tendon. PMID:25640108

  11. MRI in flexor tendon rupture after collagenase injection

    International Nuclear Information System (INIS)

    Khurana, Shruti; Wadhwa, Vibhor; Chhabra, Avneesh; Amirlak, Bardia

    2017-01-01

    Flexor tendon rupture is an unusual complication following collagenase injection to relieve contractures. These patients require a close follow-up and in the event of tendon rupture, a decision has to be made whether to repair the tendon or manage the complication conservatively. The authors report the utility of MRI in the prognostication and management of a patient with Dupuytren's contracture, who underwent collagenase injection and subsequently developed flexor digitorum profundus tendon rupture. (orig.)

  12. MRI in flexor tendon rupture after collagenase injection

    Energy Technology Data Exchange (ETDEWEB)

    Khurana, Shruti [Lady Hardinge Medical College, New Delhi (India); Wadhwa, Vibhor [University of Arkansas for Medical Sciences, Little Rock, AR (United States); Chhabra, Avneesh [UT Southwestern Medical Center, Dallas, TX (United States); Johns Hopkins University, Baltimore, MD (United States); Amirlak, Bardia [UT Southwestern Medical Center, Dallas, TX (United States)

    2017-02-15

    Flexor tendon rupture is an unusual complication following collagenase injection to relieve contractures. These patients require a close follow-up and in the event of tendon rupture, a decision has to be made whether to repair the tendon or manage the complication conservatively. The authors report the utility of MRI in the prognostication and management of a patient with Dupuytren's contracture, who underwent collagenase injection and subsequently developed flexor digitorum profundus tendon rupture. (orig.)

  13. Hydroxyapatite particles maintain peri-implant bone mantle during osseointegration in osteoporotic bone

    NARCIS (Netherlands)

    Tami, A.E.; Leitner, M.M.; Baucke, M.G.; Mueller, T.L.; Lenthe, van G.H.; Müller, R.; Ito, K.

    2009-01-01

    In osteoporotic bones, resorption exceeds formation during the remodelling phase of bone turnover. As a consequence, decreased bone volume and bone contact result in the peri-implant region. This may subsequently lead to loss of fixation. In this study we investigated whether the presence of

  14. Nanostructured implant surface effect on osteoblast gene expression and bone-to-implant contact in vivo

    Energy Technology Data Exchange (ETDEWEB)

    Mendonca, Gustavo, E-mail: gustavo_mendonca@dentistry.unc.edu [Universidade Catolica de Brasilia, Pos-Graduacao em Ciencias Genomicas e Biotecnologia, SGAN Quadra 916, Modulo B, Av. W5 Norte 70.790-160-Asa Norte Brasilia/DF (Brazil); Bone Biology and Implant Therapy Laboratory, Department of Prosthodontics, University of North Carolina at Chapel Hill, 404 Brauer Hall, CB 7450, Chapel Hill, NC 27511 (United States); Universidade Catolica de Brasilia, Curso de Odontologia, Taguatinga/DF (Brazil); Baccelli Silveira Mendonca, Daniela [Universidade Catolica de Brasilia, Pos-Graduacao em Ciencias Genomicas e Biotecnologia, SGAN Quadra 916, Modulo B, Av. W5 Norte 70.790-160-Asa Norte Brasilia/DF (Brazil) and Bone Biology and Implant Therapy Laboratory, Department of Prosthodontics, University of North Carolina at Chapel Hill, 404 Brauer Hall, CB 7450, Chapel Hill, NC 27511 (United States); Pagotto Simoes, Luis Gustavo; Araujo, Andre Luis; Leite, Edson Roberto [Departmento de Quimica, Universidade Federal de Sao Carlos-UFSCAR, Rod. Washington Luiz, 13565-905 Sao Carlos, SP (Brazil); Golin, Alexsander Luiz [Departmento de Engenharia Mecanica, Faculdade de Engenharia Mecanica, Pontificia Universidade Catolica de Curitiba, Curitiba, PR (Brazil); Aragao, Francisco J.L. [Universidade Catolica de Brasilia, Pos-Graduacao em Ciencias Genomicas e Biotecnologia, SGAN Quadra 916, Modulo B, Av. W5 Norte 70.790-160-Asa Norte Brasilia/DF (Brazil); Embrapa Recursos Geneticos e Biotecnologia, Laboratorio de Introducao e Expressao de Genes, PqEB W5 Norte, 70770-900, Brasilia, DF (Brazil); Cooper, Lyndon F., E-mail: lyndon_cooper@dentistry.unc.edu [Bone Biology and Implant Therapy Laboratory, Department of Prosthodontics, University of North Carolina at Chapel Hill, 404 Brauer Hall, CB 7450, Chapel Hill, NC 27511 (United States)

    2011-12-01

    The aim of this study was to investigate the response of nanostructured implant surfaces at the level of osteoblast differentiation and its effects in bone-to-implant contact (BIC) and removal-torque values (RTV). CpTi grade IV implants (1.6 x 4.0 mm) were machined or machined and subsequently coated with an oxide solution. The surfaces were divided into: machined (M), titania-anatase (An), titania-rutile (Ru), and zirconia (Zr). Surfaces were examined by scanning electron microscopy, atomic force microscopy, and by X-ray microanalysis. Implants were inserted in rat tibia and harvested from 0 to 21 days for measurement of Alkaline Phosphatase, Bone Sialoprotein, Osteocalcin, Osteopontin, and RUNX-2 mRNA levels by real time PCR; from 0 to 56 days for RTV; and from 0 to 56 days for BIC. The roughness parameter (Sa) was compared by one-way ANOVA followed by Tukey Test. Comparison of Torque removal values and histomorphometric measurements on implants in vivo was performed by Kruskal-Wallis test and the significance level for all statistical analyses was set at p {<=} 0.05. mRNA levels on all nanostructured surfaces were increased compared to M. At 56 days, the mean RTV in Ncm was 11.6 {+-} 2.5, 11.3 {+-} 2.4, 11.1 {+-} 3.5, 9.7 {+-} 1.4 for An, Ru, Zr, and M, respectively. Higher BIC (%) was measured for all the nanostructured surfaces versus M at 21 and 56 days (p < 0.05). Nanostructured topographic features composed of TiO{sub 2} or ZrO{sub 2} applied to machined cpTi implant promoted greater mesenchymal stem cell commitment to the osteoblast phenotype and associated increased BIC and physical association with bone. Highlights: {yields} Nanostructured surfaces using a sol-gel technique coated cpTi with TiO{sub 2} or ZrO{sub 2}. {yields} Evaluated molecular and mechanical effect of nanofeatures in vivo in rat tibiae. {yields} Nanofeatures improved the differentiation of rat MSCs into osteoblasts. {yields} Nanofeatures improved increased bone-to-implant contact and

  15. Nanostructured implant surface effect on osteoblast gene expression and bone-to-implant contact in vivo

    International Nuclear Information System (INIS)

    Mendonca, Gustavo; Baccelli Silveira Mendonca, Daniela; Pagotto Simoes, Luis Gustavo; Araujo, Andre Luis; Leite, Edson Roberto; Golin, Alexsander Luiz; Aragao, Francisco J.L.; Cooper, Lyndon F.

    2011-01-01

    The aim of this study was to investigate the response of nanostructured implant surfaces at the level of osteoblast differentiation and its effects in bone-to-implant contact (BIC) and removal-torque values (RTV). CpTi grade IV implants (1.6 x 4.0 mm) were machined or machined and subsequently coated with an oxide solution. The surfaces were divided into: machined (M), titania-anatase (An), titania-rutile (Ru), and zirconia (Zr). Surfaces were examined by scanning electron microscopy, atomic force microscopy, and by X-ray microanalysis. Implants were inserted in rat tibia and harvested from 0 to 21 days for measurement of Alkaline Phosphatase, Bone Sialoprotein, Osteocalcin, Osteopontin, and RUNX-2 mRNA levels by real time PCR; from 0 to 56 days for RTV; and from 0 to 56 days for BIC. The roughness parameter (Sa) was compared by one-way ANOVA followed by Tukey Test. Comparison of Torque removal values and histomorphometric measurements on implants in vivo was performed by Kruskal-Wallis test and the significance level for all statistical analyses was set at p ≤ 0.05. mRNA levels on all nanostructured surfaces were increased compared to M. At 56 days, the mean RTV in Ncm was 11.6 ± 2.5, 11.3 ± 2.4, 11.1 ± 3.5, 9.7 ± 1.4 for An, Ru, Zr, and M, respectively. Higher BIC (%) was measured for all the nanostructured surfaces versus M at 21 and 56 days (p 2 or ZrO 2 applied to machined cpTi implant promoted greater mesenchymal stem cell commitment to the osteoblast phenotype and associated increased BIC and physical association with bone. Highlights: → Nanostructured surfaces using a sol-gel technique coated cpTi with TiO 2 or ZrO 2 . → Evaluated molecular and mechanical effect of nanofeatures in vivo in rat tibiae. → Nanofeatures improved the differentiation of rat MSCs into osteoblasts. → Nanofeatures improved increased bone-to-implant contact and removal torque values. → TiO 2 or ZrO 2 nanofeatures improved the biological response of machined titanium.

  16. Influência da decorticação vertebral na neoformação dos tecidos da interface do enxerto ósseo Influence of vertebral decortication on tissue neoformation at bone graft interface

    Directory of Open Access Journals (Sweden)

    Fabiano Ricardo Tavares Canto

    2010-01-01

    Full Text Available OBJETIVO: Determinar a influência da decorticação dos elementos posteriores da coluna vertebral na integração do enxerto ósseo, considerando a avaliação quantitativa e qualitativa dos tecidos (ósseo, cartilaginoso e fibroso da interface entre o leito receptor e o enxerto ósseo. MÉTODOS: Foram utilizados 24 ratos Wistar, divididos em dois grupos de acordo com a realização da decorticação do leito receptor do enxerto. Foi utilizado enxerto autólogo derivado dos processos espinhosos das duas primeiras vértebras lombares. A neoformação tecidual na interface entre o leito receptor e seu enxerto ósseo foi avaliada após três semanas por meio de análise histomorfométrica. RESULTADOS: No grupo de animais com o leito receptor decorticado a média da porcentagem de osso neoformado foi de 40%±6,1, e 7,7%± 3,5 no grupo não decorticado (p=0,0001. A média da porcentagem de formação do tecido cartilaginoso no grupo decorticado foi de 7,2%±3,5, no não decorticado de 10,9%±5,6 (p=0,1123. A formação de tecido fibroso no grupo decorticado apresentou média de 8,6%±3,9 e no não decorticado e 24%±10,1, (p=0,0002. CONCLUSÕES: A decorticação acelerou o processo histológico da integração do enxerto ósseo. Ocorrendo maior produção de tecido ósseo neoformado e predomínio da ossificação do tipo intramembranosa no grupo de animais nos quais a decorticação foi realizada.OBJECTIVE: To determine the influence of vertebral posterior elements decortication in bone graft integration, considering a qualitative and quantitative evaluation of the (bone, cartilaginous, and fibrous tissues in the interface between the receptor bed and the bone graft. METHODS: Twenty-four Wistar rats were divided into two groups according to the decortication of the bone graft receptor bed. Autologous bone graft from the first and second lumbar vertebrae were used. The new tissue formation in the interface between the receptor bed and its bone graft

  17. Determination of the frictional coefficient of the implant-antler interface: experimental approach.

    Science.gov (United States)

    Hasan, Istabrak; Keilig, Ludger; Staat, Manfred; Wahl, Gerhard; Bourauel, Christoph

    2012-10-01

    The similar bone structure of reindeer antler to human bone permits studying the osseointegration of dental implants in the jawbone. As the friction is one of the major factors that have a significant influence on the initial stability of immediately loaded dental implants, it is essential to define the frictional coefficient of the implant-antler interface. In this study, the kinetic frictional forces at the implant-antler interface were measured experimentally using an optomechanical setup and a stepping motor controller under different axial loads and sliding velocities. The corresponding mean values of the static and kinetic frictional coefficients were within the range of 0.5-0.7 and 0.3-0.5, respectively. An increase in the frictional forces with increasing applied axial loads was registered. The measurements showed an evidence of a decrease in the magnitude of the frictional coefficient with increasing sliding velocity. The results of this study provide a considerable assessment to clarify the suitable frictional coefficient to be used in the finite element contact analysis of antler specimens.

  18. Nonoperative, dynamic treatment of acute achilles tendon rupture

    DEFF Research Database (Denmark)

    Barfod, Kristoffer Weisskirchner; Bencke, Jesper; Lauridsen, Hanne Bloch

    2015-01-01

    Acute Achilles tendon rupture alters the biomechanical properties of the plantar flexor muscle-tendon complex that can affect functional performance and the risk of repeat injury. The purpose of the present study was to compare the biomechanical properties of the plantar flexor muscle-tendon comp......Acute Achilles tendon rupture alters the biomechanical properties of the plantar flexor muscle-tendon complex that can affect functional performance and the risk of repeat injury. The purpose of the present study was to compare the biomechanical properties of the plantar flexor muscle...... in the terminal part of dorsiflexion was found in the non-weightbearing group. The altered stiffness and strength in the affected limb could affect the coordination of gait and running....

  19. Exercise following a short immobilization period is detrimental to tendon properties and joint mechanics in a rat rotator cuff injury model.

    Science.gov (United States)

    Peltz, Cathryn D; Sarver, Joseph J; Dourte, Leann M; Würgler-Hauri, Carola C; Williams, Gerald R; Soslowsky, Louis J

    2010-07-01

    Rotator cuff tears are a common clinical problem that can result in pain and disability. Previous studies in a rat model showed enhanced tendon to bone healing with postoperative immobilization. The objective of this study was to determine the effect of postimmobilization activity level on insertion site properties and joint mechanics in a rat model. Our hypothesis was that exercise following a short period of immobilization will cause detrimental changes in insertion site properties compared to cage activity following the same period of immobilization, but that passive shoulder mechanics will not be affected. We detached and repaired the supraspinatus tendon of 22 Sprague-Dawley rats, and the injured shoulder was immobilized postoperatively for 2 weeks. Following immobilization, rats were prescribed cage activity or exercise for 12 weeks. Passive shoulder mechanics were determined, and following euthanasia, tendon cross-sectional area and mechanical properties were measured. Exercise following immobilization resulted in significant decreases compared to cage activity in range of motion, tendon stiffness, modulus, percent relaxation, and several parameters from both a structurally based elastic model and a quasi-linear viscoelastic model. Therefore, we conclude that after a short period of immobilization, increased activity is detrimental to both tendon mechanical properties and shoulder joint mechanics, presumably due to increased scar production. (c) 2010 Orthopaedic Research Society. Published by Wiley Periodicals, Inc

  20. Histologic evaluation of the bone-ceramic interface of an alumina ceramic cup arthroplasty retrieved after 25 years in vivo

    Directory of Open Access Journals (Sweden)

    Fuminori Higuchi, MD

    2016-09-01

    Full Text Available A 47-year-old man underwent ceramic cup arthroplasty when he was 22 years old. Revision total hip arthroplasty was performed 25 years later because of limited range of motion without implant loosening. Histologic examination revealed that the femoral head and ceramic implant were well fixed through a thin fibrous membrane. The energy-dispersive X-ray analysis indicated that calcium and phosphorus were detected in the same peak pattern as cancellous bone in the bone-ceramic interface.