WorldWideScience

Sample records for ten-minute single sample

  1. Validation of ten-minute single sample carbon-14 urea breath test for diagnosis of Helicobacter pylori infection

    International Nuclear Information System (INIS)

    Prabakaran, K.; Fernandes, V.; McDonald, J.

    1996-01-01

    Helicobacter pylori infection is traditionally diagnosed by endoscopy followed by gastric biopsy and histologic demonstration of organisms, rapid urease test and culture. The non-invasive carbon-14-urea breath test has been widely accepted now for the diagnosis of this bacterium. This study was aimed to establish and validate normal and abnormal values for an Australian population, for a single sample carbon-14-urea breath test at ten minutes. A dose of 185 kBq was used in order to achieve reasonable counting statistics. The derived values were validated with the results of the rapid urease test. This method has a high sensitivity, specificity and greater patient acceptance, and could be used in many clinical settings as the first modality for the diagnosis of H. pylori infection and for documenting response or cure after antibiotic therapy for eradication. 11 refs., 1 tab., 4 figs

  2. "Take ten minutes": a dedicated ten minute medication review reduces polypharmacy in the elderly.

    LENUS (Irish Health Repository)

    Walsh, E K

    2012-02-01

    Multiple and inappropriate medications are often the cause for poor health status in the elderly. Medication reviews can improve prescribing. This study aimed to determine if a ten minute medication review by a general practitioner could reduce polypharmacy and inappropriate prescribing in elderly patients. A prospective, randomised study was conducted. Patients over the age of 65 (n = 50) underwent a 10-minute medication review. Inappropriate medications, dosage errors, and discrepancies between prescribed versus actual medication being consumed were recorded. A questionnaire to assess satisfaction was completed following review. The mean number of medications taken by patients was reduced (p < 0.001). A medication was stopped in 35 (70%) patients. Inappropriate medications were detected in 27 (54%) patients and reduced (p < 0.001). Dose errors were detected in 16 (32%). A high level of patient satisfaction was reported. A ten minute medication review reduces polypharmacy, improves prescribing and is associated with high levels of patient satisfaction.

  3. "Take ten minutes": a dedicated ten minute medication review reduces polypharmacy in the elderly.

    LENUS (Irish Health Repository)

    Walsh, E K

    2010-09-01

    Multiple and inappropriate medications are often the cause for poor health status in the elderly. Medication reviews can improve prescribing. This study aimed to determine if a ten minute medication review by a general practitioner could reduce polypharmacy and inappropriate prescribing in elderly patients. A prospective, randomised study was conducted. Patients over the age of 65 (n = 50) underwent a 10-minute medication review. Inappropriate medications, dosage errors, and discrepancies between prescribed versus actual medication being consumed were recorded. A questionnaire to assess satisfaction was completed following review. The mean number of medications taken by patients was reduced (p < 0.001). A medication was stopped in 35 (70%) patients. Inappropriate medications were detected in 27 (54%) patients and reduced (p < 0.001). Dose errors were detected in 16 (32%). A high level of patient satisfaction was reported. A ten minute medication review reduces polypharmacy, improves prescribing and is associated with high levels of patient satisfaction.

  4. The Ten-Minute Neighbourhood Is [not] a Basic Planning Unit for Happiness in Egypt

    Directory of Open Access Journals (Sweden)

    Abeer Mohamed Elshater

    2016-04-01

    Full Text Available This paper investigates the relationship between inhabitants’ happiness and the right to the city in the status quo of Egyptian neighborhoods. Although services are easily accessible, by ten-minute walks in a suitable ambience, happiness is not achieved. The research aims to, first, review the literature that provides a guideline for ten-minute neighborhoods. Second, this study conducts a comparative content analysis of recent online articles on the right to the city. Third, the study tests findings from Egyptian neighborhood settings. The idea of a ten-minute neighborhood is manageable. The hypothesis concerns a compliant design. It is a logical assumption that people who live within ten minutes walking distance of essential facilities in their area can minimize several problems and maximize a healthy lifestyle. The supposed issue causes the right to the city to affect the relationship between ten-minute neighborhoods and citizens’ happiness. This assumption can be established through site observation and oriented questionnaires. This paper contributes by presenting new planning units that suit the current context of the old cities in the Middle East and North Africa region, based on walking distances of ten minutes or less with reference to the right to the city. This planning unit can result in citizens’ happiness.

  5. Reduction In Setup Time By Single Minute Exchange Of Dies SMED Methodology

    Directory of Open Access Journals (Sweden)

    Pallavi A. Gade

    2015-08-01

    Full Text Available Life is a race if you dont chase it someone is definitely chase you and will go ahead. Hence to survive in todays business world every manufacturer has to have some idea and plans for their betterment. Market scenario has nearly change after 1990s that every manufacturer must go through the global competition demand for short lead time demand for variety small lot sizes and also proliferation of OEMs. If we have to increase the frequency of delivery without compromising the quality Single Minute Exchange of Dies is the answer. Single Minute Exchange of Dies is not only apply to bottleneck machines it is to be implemented company wide and aim must be to bring all setup time to less than ten minutes in this paper some techniques basic procedure problems faced by companies are discussed and solution for them are suggested.

  6. A randomized trial to determine the duration of analgesia following a 15- and a 30-minute application of acupuncture-like TENS on patients with chronic low back pain.

    Science.gov (United States)

    Tousignant-Laflamme, Yannick; Laroche, Claudia; Beaulieu, Christine; Bouchard, Ann-Julie; Boucher, Sabrina; Michaud-Létourneau, Mélanie

    2017-05-01

    Acupuncture-like TENS (AL-TENS) has been shown to produce prolonged pain relief, but no study has yet investigated its duration on a population suffering from chronic low back pain (CLPB). Our objective was to quantify the duration and magnitude of analgesia induced by a 15- or 30-minute application of AL-TENS. We recruited a sample of 11 participants presenting with CLBP and conducted a randomized, crossover study, where participants were given AL-TENS for 15 and 30 minutes on two separate occasions. The pain intensity of their CLBP was assessed with a visual analogue scale before, during, and after AL-TENS applications. Magnitude and duration of analgesia were determined for each subject and for both AL-TENS application times. The AL-TENS applications induced a clinically and statistically significant (p = 0.003) analgesia in all participants. Median duration of analgesia was 9 hours and 10 hours 30 minutes following the 15- and 30-minute AL-TENS applications, respectively; this 1.5-hour difference was not statistically significant (p = 0.55). Furthermore, we observed no significant difference in the magnitude of analgesia between both applications of AL-TENS (p > 0.56), suggesting that the duration of application of AL-TENS does not influence the magnitude of analgesia. Our results suggest that clinicians could use a 15-minute AL-TENS application to provide significant analgesia in patients presenting with low back pain since if provides a comparable analgesia versus a 30-minute application.

  7. Cross section survey of public emergency response on the "National Day of Emergency Platinum Ten Minute-Self and Mutual Rescue" in some areas

    Directory of Open Access Journals (Sweden)

    Zhong-jie HE

    2015-11-01

    Full Text Available Objective To explore the difference in level of first-aid capability and consciousness of the masses in different regions of China. Methods The survey was performed by filling the questionnaire on the "National Day of Emergency Platinum Ten Minutes" over the country China on October 10, 2014. The data were analyzed by SPSS 13.0 software. Results A total of 1580 questionnaires were returned from 16 cities, and among them 1422 were valid. The highest age of the subjects involved in the investigation was 83 years, the youngest 14 years, with the mean age 40.2 years. There were 483 men and 703 women, of whom 767(64.7% had heard of the "platinum ten minutes" project. 57.8% people believed that the "platinum ten minutes" was their own affair. 52.0% of them offered that they would call the emergency system when met an emergency; 83.8% did not have the experience of dealing with an accident; only 53.2% of them had actively learned first aid knowledge from TV, training schools, newspapers, extracurricular training etc. 27.2% of the people thought that they were not able to deal with accident or emergency of their families. On the scene of an injury, only 30.4% of the people would be willing to deal with the accident only when they were asked to. The scores of the middle, northeast, coastal and northwest regions were 80, 70, 60 and 50 (P60 year were 90, 80, 70 and 50 (P<0.05. The scores of the people who had received education of first aid and mutual aid (90 points were higher than those without training (70, P<0.05. The scores (71 points of the people who had heard "platinum ten minutes" were higher than those of ignorant of it (63 points, P<0.05. The people who received the training of both "first aid" and "platinum ten minutes" won the highest score (77 points. The people who have not learned "first aid" but only learned the "platinum ten minutes" got 69 points, those had learned first aid, but did not learn "platinum ten minutes" (67 had lower

  8. Proteomic analysis of minute amount of colonic biopsies by enteroscopy sampling

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Xing [Department of Analytical Chemistry and CAS Key Laboratory of Receptor Research, Shanghai Institute of Materia Medica, Chinese Academy of Sciences (China); Xu, Yanli [Fuyang People’s Hospital (China); Meng, Qian [Department of Analytical Chemistry and CAS Key Laboratory of Receptor Research, Shanghai Institute of Materia Medica, Chinese Academy of Sciences (China); Zheng, Qingqing [Digestive Endoscopic Center, Shanghai Jiaotong University Affiliated Sixth People’s Hospital (China); Wu, Jianhong [Department of Analytical Chemistry and CAS Key Laboratory of Receptor Research, Shanghai Institute of Materia Medica, Chinese Academy of Sciences (China); Wang, Chen; Jia, Weiping [Shanghai Key Laboratory of Diabetes Mellitus, Department of Endocrinology and Metabolism, Shanghai Diabetes Institute, Shanghai Clinical Center for Diabetes, Shanghai Jiao Tong University Affiliated Sixth People’s Hospital (China); Figeys, Daniel [Department of Biochemistry, Microbiology and Immunology, and Department of Chemistry and Biomolecular Sciences, University of Ottawa (Canada); Chang, Ying, E-mail: emulan@163.com [Digestive Endoscopic Center, Shanghai Jiaotong University Affiliated Sixth People’s Hospital (China); Zhou, Hu, E-mail: zhouhu@simm.ac.cn [Department of Analytical Chemistry and CAS Key Laboratory of Receptor Research, Shanghai Institute of Materia Medica, Chinese Academy of Sciences (China)

    2016-08-05

    Colorectal cancer (CRC) is one of the most common types of malignant tumor worldwide. Currently, although many researchers have been devoting themselves in CRC studies, the process of locating biomarkers for CRC early diagnosis and prognostic is still very slow. Using a centrifugal proteomic reactor-based proteomic analysis of minute amount of colonic biopsies by enteroscopy sampling, 2620 protein groups were quantified between cancer mucosa and adjacent normal colorectal mucosa. Of which, 403 protein groups were differentially expressed with statistic significance between cancer and normal tissues, including 195 up-regulated and 208 down-regulated proteins in cancer tissues. Three proteins (SOD3, PRELP and NGAL) were selected for further Western blot validation. And the resulting Western blot experimental results were consistent with the quantitative proteomic data. SOD3 and PRELP are down-regulated in CRC mucosa comparing to adjacent normal tissue, while NGAL is up-regulated in CRC mucosa. In conclusion, the centrifugal proteomic reactor-based label-free quantitative proteomic approach provides a highly sensitive and powerful tool for analyzing minute protein sample from tiny colorectal biopsies, which may facilitate CRC biomarkers discovery for diagnoses and prognoses. -- Highlights: •Minute amount of colonic biopsies by endoscopy is suitable for proteomic analysis. •Centrifugal proteomic reactor can be used for processing tiny clinic biopsy sample. •SOD3 and PRELP are down-regulated in CRC, while NGAL is up-regulated in CRC.

  9. Proteomic analysis of minute amount of colonic biopsies by enteroscopy sampling

    International Nuclear Information System (INIS)

    Liu, Xing; Xu, Yanli; Meng, Qian; Zheng, Qingqing; Wu, Jianhong; Wang, Chen; Jia, Weiping; Figeys, Daniel; Chang, Ying; Zhou, Hu

    2016-01-01

    Colorectal cancer (CRC) is one of the most common types of malignant tumor worldwide. Currently, although many researchers have been devoting themselves in CRC studies, the process of locating biomarkers for CRC early diagnosis and prognostic is still very slow. Using a centrifugal proteomic reactor-based proteomic analysis of minute amount of colonic biopsies by enteroscopy sampling, 2620 protein groups were quantified between cancer mucosa and adjacent normal colorectal mucosa. Of which, 403 protein groups were differentially expressed with statistic significance between cancer and normal tissues, including 195 up-regulated and 208 down-regulated proteins in cancer tissues. Three proteins (SOD3, PRELP and NGAL) were selected for further Western blot validation. And the resulting Western blot experimental results were consistent with the quantitative proteomic data. SOD3 and PRELP are down-regulated in CRC mucosa comparing to adjacent normal tissue, while NGAL is up-regulated in CRC mucosa. In conclusion, the centrifugal proteomic reactor-based label-free quantitative proteomic approach provides a highly sensitive and powerful tool for analyzing minute protein sample from tiny colorectal biopsies, which may facilitate CRC biomarkers discovery for diagnoses and prognoses. -- Highlights: •Minute amount of colonic biopsies by endoscopy is suitable for proteomic analysis. •Centrifugal proteomic reactor can be used for processing tiny clinic biopsy sample. •SOD3 and PRELP are down-regulated in CRC, while NGAL is up-regulated in CRC.

  10. Single-subject withdrawal designs in delayed matching-to-sample procedures

    OpenAIRE

    Eilifsen, Christoffer; Arntzen, Erik

    2011-01-01

    In most studies of delayed matching-to-sample (DMTS) and stimulus equivalence, the delay has remained fixed throughout a single experimental condition. We wanted to expand on the DMTS and stimulus equivalence literature by examining the effects of using titrating delays with different starting points during the establishment of conditional discriminations prerequisite for stimulus equivalence. In Experiment 1, a variation of a single-subject withdrawal design was used. Ten adults were exposed...

  11. The Growing Trend of Reading Movements in Japan: Animacion a la Lectura, Ten-Minutes Reading in the Morning, and Reading Aloud by Parents.

    Science.gov (United States)

    Adachi, Sachiko

    This study examines the growing trend of reading movements in Japan and their origins. There are three main movements: Animacion a la Lectura; Ten-Minutes Reading in the Morning; and Reading Aloud by Parents in schools. This paper reports on the three movements from a review of the literature, personal observations, and practice. The paper…

  12. Minutes of the 28th Annual Plutonium Sample Exchange Meeting. Part II: metal sample exchange

    International Nuclear Information System (INIS)

    1984-01-01

    Contents of this publication include the following list of participating laboratories; agenda; attendees; minutes of October 25 and 26 meeting; and handout materials supplied by speakers. The handout materials cover the following: statistics and reporting; plutonium - chemical assay 100% minus impurities; americium neptunium, uranium, carbon and iron data; emission spectroscopy data; plutonium metal sample exchange; the calorimetry sample exchange; chlorine determination in plutonium metal using phyrohydrolysis; spectrophotometric determination of 238-plutonium in oxide; plutonium measurement capabilities at the Savannah River Plant; and robotics in radiochemical laboratory

  13. A precise evaluation of glomerular filtration rate (GFR) in two plasma samples following a single administration of 57Co-B12 vitamin

    International Nuclear Information System (INIS)

    Camargo, E.E.; Rockmann, R.L.; Barreto, T.M.; Eston, T.E.; Papaleo Netto, M.; Carvalho, N.

    1974-01-01

    Through a logarithmic regression performed with the contings of 4 plasma samples withdrawn at 20,40,60 and 80 minutes after a venous injection of vitamin B 12 - 57 Co, the glomerular filtration-rate(GFR) in 11 patients, performing simultaneously the same study with EDTA- 51 Cr in 3 of them, is evaluated. The values obtained through the regression straight line are compared with those given by only 2 points, in the 6 possible combinations: 20 and 40 minutes, 20 and 60 minutes, 20 and 80 minutes, 40 and 60 minutes, 40 and 80 minutes, 60 and 80 minutes. The pair of points obtained at 20 and 80 minutes determined the straight line most similar to the logarithmic regression and as a simplification of the method, the withdraw of only 2 plasma samples, at and 80 minutes after a single injection of vitamin B 12 -57 Co is proposed [pt

  14. Minutes of the 28th annual plutonium sample exchange meeting. Part I: isotopic sample exchange

    International Nuclear Information System (INIS)

    1984-01-01

    Contents of this publication include the following: list of participating laboratories; agenda; attendees; minutes of October 24 meeting; and handout materials supplied by speakers. The handout materials cover the following: interlaboratory comparisons of plutonium isotope ratios. The plutonium ratios considered are 240/239, 241/239, 242/239, 238/239, 239/240, 241/240, 242/240, and 238/240; carbon, uranium, iron, and nickel data; mass spectroscopy data; determination of plutonium 241 half-life; review of plutonium overplating sample loading technique; on-line measurement evaluation system for isotopic analysis; and description of a new thermal ionization mass spectrometer

  15. Immediate effects of tongue trills associated with transcutaneous electrical nerve stimulation (TENS).

    Science.gov (United States)

    Fabron, Eliana Maria Gradim; Petrini, Andressa Schweitzer; Cardoso, Vanessa de Moraes; Batista, João Carlos Torgal; Motonaga, Suely Mayumi; Marino, Viviane Cristina de Castro

    2017-06-08

    To investigate vocal quality variability after applying tongue trills associated with transcutaneous electrical nerve stimulation (TENS) on the larynx of women with normal laryngeal function. Additionally, to verify the effect of this technique over time on voice quality. Participants were 40 women (average 23.4 years) without vocal complaints. The procedure involved tongue trills with or without TENS for 3 minutes, rest and repeating the technique for another 2 minutes. The participants' voices were recorded before (Pre), after three minutes (Post 3min) and after two additional minutes (Post 5min) applying the technique. TENS with two electrodes was used on the thyroid cartilage. Self-assessment, acoustic and perceptual analysis were performed. When comparing tongue trills in isolation and associated with TENS, a greater sense of stability in phonation (self-assessment) and improvement in voice quality (perceptual evaluation) was observed in the combination technique. There was no statistical difference in acoustics findings between tongue trills in isolation and associated with TENS. When comparing the time effect of tongue trills with TENS in self-assessment there was a perception of less muscle tension (3min) and greater comfort during phonation (5 min); in the acoustic analysis, there was an increase of F0 (3 and 5 min) and intensity (5 min) when compared to Pre-moment; in the perceptual evaluation, better voice quality (3min). Comparing tongue trills in isolation and associated with TENS, there were changes in the comfort and muscle tension perception, as well as in vocal quality. On the other hand, tongue trills associated with TENS performed in 3 or 5 minutes resulted in beneficial effects on the voice identified in the assessments.

  16. The effectiveness of single minute exchange of dies for lean changeover process in printing industry

    Directory of Open Access Journals (Sweden)

    Indrawati Sri

    2018-01-01

    Full Text Available The changeover time is a factor that greatly affects the lean production implementation in industry with make to order system. Large product variations and unpredictable quantity of orders will trigger some kind of production wastes if changeover time is done in a longer time. One industry with make to order system is printing industry. In general, to produce several types of products such as books takes quite a long time because of long production changeover process. The general problem faced is the delay in book’s production completion. Based on this problem, changeover time reduction is needed to overcome the delay of book’s production completion using single minute exchanges of dies (SMED method. The SMED method is the method that separates the changeover activity into two, i.e. internal setup and external setup. The research shows that changeover time for printing workstation is 18 minutes 29 seconds, which consists of internal setup activities 14 minutes 37 seconds and external setup 4 minutes 33 seconds. By converting 45% of the internal setup activity into an external setup, then the setup time can be reduced. The initial setup activities performed when machine is stop, now can be done when the machine is running. In addition, a changeover process improvement also done using 5S method in workstation tools area so the internal setup time is reduced 46% becomes 7 minutes 59 seconds. Under these conditions, the printing industry can increase production by 2%.

  17. Transcutaneous Electrical Nerve Stimulation (TENS) reduces pain, fatigue, and hyperalgesia while restoring central inhibition in primary fibromyalgia

    Science.gov (United States)

    Dailey, Dana L; Rakel, Barbara A; Vance, Carol GT; Liebano, Richard E; Anand, Amrit S; Bush, Heather M; Lee, Kyoung S; Lee, Jennifer E; Sluka, Kathleen A

    2014-01-01

    Because TENS works by reducing central excitability and activating central inhibition pathways, we tested the hypothesis that TENS would reduce pain and fatigue and improve function and hyperalgesia in people with fibromyalgia who have enhanced central excitability and reduced inhibition. The current study used a double-blinded randomized, placebo controlled cross-over design to test effects of a single treatment of TENS in people with fibromyalgia. Three treatments were assessed in random order: active TENS, placebo TENS, no TENS. The following measures were assessed before and after each TENS treatment: pain and fatigue at rest and movement, pressure pain thresholds (PPTs), 6 minute walk test (6MWT), range of motion (ROM), five time sit to stand test (FTSTS), and single leg stance (SLS). Conditioned pain modulation (CPM) was completed at end of testing. There was a significant decrease in pain and fatigue with movement for active TENS compared to placebo and no TENS. PPTs increased at site of TENS (spine) and outside site of TENS (leg) when compared to placebo TENS or no TENS. During Active TENS CPM was significantly stronger compared to placebo TENS and no TENS. No changes in functional tasks were observed with TENS. Thus, the current study suggests TENS has short-term efficacy in relieving symptoms of fibromyalgia while the stimulator is active. Future clinical trials should examine the effects of repeated daily delivery of TENS, similar to how TENS is used clinically, on pain, fatigue, function and quality of life in individuals with fibromyalgia. PMID:23900134

  18. Ten-minute chat.

    Science.gov (United States)

    Scott, Claire

    2017-05-27

    Claire Scott is a fourth-year student at the Royal Veterinary College. She has embarked on rotations and completed several of her required extramural studies weeks, including one spent with Veterinary Record . British Veterinary Association.

  19. Preparation of minute particle using supercritical fluid; Chorinkai ryutai wo mochiita biryushi no chosei

    Energy Technology Data Exchange (ETDEWEB)

    Ajiri, T [Tohoku University, Sendai (Japan). Faculty of Engineering

    1995-03-05

    The metal oxide minute particle synthesis method according to the water-heat reaction in supercritical water was described. Metal salt liquid solution was subjected to hydrolysis when heated to become metal hydroxide but dehydration reaction was generated at a high temperature to generate metal oxide minute particle. Metal salt aqueous solution was supplied to a circulation system unit to contact heated water and was rapidly heated to supercritical state and then was subjected to hydrolysis/dehydration reaction, thus continuously collecting metal oxide minute particles. The hydrolysis speed was in first order for the metal ion concentration and the reaction speed was accelerated by several tens of times when entering supercritical region from subcritical region. When the temperature was rapidly increased to the supercritical state, a radical hydrolysis was generated and a high saturation was instantly reached and minute particles tended to be generated easily since the dissolution force of supercritical water for a product was small. A minute particle with a crystallizability of 5 nm was obtained by synthesizing ceria super-minute particle which was the abrasive of an optical glass material. A single phase of a high magnetization characteristic was synthesized continuously and quickly (faster than a conventional method by two orders or more) in the continuous synthesis of Ba ferrite as a magnetic recording material. 12 refs., 3 figs., 1 tab.

  20. TRANSCUTANEOUS ELECTRICAL NERVE-STIMULATION (TENS) IN RAYNAUDS-PHENOMENON

    NARCIS (Netherlands)

    MULDER, P; DOMPELING, EC; VANSLOCHTERENVANDERBOOR, JC; KUIPERS, WD; SMIT, AJ

    Transcutaneous nerve stimulation (TENS) has been described as resulting in vasodilatation. The effect of 2 Hz TENS of the right hand during forty-five minutes on skin temperature and plethysmography of the third digit of both hands and feet and on transcutaneous oxygen tension (TcpO2) of the right

  1. The comparison of application of two different frequencies of TENS on excitability of Hoffmann reflex

    Directory of Open Access Journals (Sweden)

    Akbari M

    2001-08-01

    Full Text Available The aim of this investigation is to compare the effect of applying two transcutaneous electrical nerve stimulation (TENS current with different frequencies (2 Hz & 100 Hz on Hoffmann reflex recorded from gastrosoleus muscle of healthy people. Forty female subjects between 20 to 30 years of age were participated in this quasi-experimental design. Twenty of them were exposed to the 100 Hz current and the remaining 20 to 2 Hz current on dermatome S1 root. The excitability of the alpha motoneurone was measured by H-reflex amplitude (peak to peak max/2 before and after the application of the TENS current for 30 minutes. The reflex was recorded and at measured before (TO and after the application of TENS at different times (T1, T% and T10 up to 10 minutes. The mean values were compared by multiple paired T test (alpha=0.00825. The results indicate a considerable decrement in Hoffmann reflex amplitude after application of 100 Hz current in comarison with that of before the application. The effect last for 10 minutes after the TENS application, whereas the application of 2 Hz current results in increment of the Hoffmann reflex amplitude. The 5 and 10 minutes interval test dose not show any significance and the results were attenuated befor 5 minutes. As a conclusion high frequency of TENS (100 Hz has an inhibitory effect on excitability of alpha motor neurone reflex lasting for 10 minutes, while low frequency of TENS (2 Hz has an facilatory effect on the same motoneurone with short lasting effect.

  2. Transcutaneous electrical nerve stimulation (TENS) for neuropathic pain in adults.

    Science.gov (United States)

    Gibson, William; Wand, Benedict M; O'Connell, Neil E

    2017-09-14

    range of treatment protocols in terms of duration of care, TENS application times and intensity of application. Briefly, duration of care ranged from four days through to three months. Similarly, we found variation of TENS application times; from 15 minutes up to hourly sessions applied four times daily. We typically found intensity of TENS set to comfortable perceptible tingling with very few studies titrating the dose to maintain this perception. Of the comparisons, we had planned to explore, we were only able to undertake a quantitative synthesis for TENS versus sham TENS. Insufficient data and large diversity in the control conditions prevented us from undertaking a quantitative synthesis for the remaining comparisons.For TENS compared to sham TENS, five studies were suitable for pooled analysis. We described the remainder of the studies in narrative form. Overall, we judged 11 studies at high risk of bias, and four at unclear risk. Due to the small number of eligible studies, the high levels of risk of bias across the studies and small sample sizes, we rated the quality of the evidence as very low for the pooled analysis and very low individual GRADE rating of outcomes from single studies. For the individual studies discussed in narrative form, the methodological limitations, quality of reporting and heterogeneous nature of interventions compared did not allow for reliable overall estimates of the effect of TENS.Five studies (across various neuropathic conditions) were suitable for pooled analysis of TENS versus sham TENS investigating change in pain intensity using a visual analogue scale. We found a mean postintervention difference in effect size favouring TENS of -1.58 (95% confidence interval (CI) -2.08 to -1.09, P Ten small studies compared TENS to some form of usual care. However, there was great diversity in what constituted usual care, precluding pooling of data. Most of these studies found either no difference in pain outcomes between TENS versus other

  3. A single trial of transcutaneous electrical nerve stimulation (TENS) improves spasticity and balance in patients with chronic stroke.

    Science.gov (United States)

    Cho, Hwi-young; In, Tae Sung; Cho, Ki Hun; Song, Chang Ho

    2013-03-01

    Spasticity management is pivotal for achieving functional recovery of stroke patients. The purpose of this study was to investigate the effects of a single trial of transcutaneous electrical nerve stimulation (TENS) on spasticity and balance in chronic stroke patients. Forty-two chronic stroke patients were randomly allocated into the TENS (n = 22) or the placebo-TENS (n = 20) group. TENS stimulation was applied to the gastrocnemius for 60 min at 100 Hz, 200 µs with 2 to 3 times the sensory threshold (the minimal threshold in detecting electrical stimulation for subjects) after received physical therapy for 30 min. In the placebo-TENS group, electrodes were placed but no electrical stimulation was administered. For measuring spasticity, the resistance encountered during passive muscle stretching of ankle joint was assessed using the Modified Ashworth Scale, and the Hand held dynamometer was used to assess the resistive force caused by spasticity. Balance ability was measured using a force platform that measures postural sway generated by postural imbalance. The TENS group showed a significantly greater reduction in spasticity of the gastrocnemius, compared to the placebo-TENS group (p TENS resulted in greater balance ability improvements, especially during the eyes closed condition (p TENS provides an immediately effective means of reducing spasticity and of improving balance in chronic stroke patients. The present data may be useful to establish the standard parameters for TENS application in the clinical setting of stroke.

  4. Development of analog watch with minute repeater

    Science.gov (United States)

    Okigami, Tomio; Aoyama, Shigeru; Osa, Takashi; Igarashi, Kiyotaka; Ikegami, Tomomi

    A complementary metal oxide semiconductor with large scale integration was developed for an electronic minute repeater. It is equipped with the synthetic struck sound circuit to generate natural struck sound necessary for the minute repeater. This circuit consists of an envelope curve drawing circuit, frequency mixer, polyphonic mixer, and booster circuit made by using analog circuit technology. This large scale integration is a single chip microcomputer with motor drivers and input ports in addition to the synthetic struck sound circuit, and it is possible to make an electronic system of minute repeater at a very low cost in comparison with the conventional type.

  5. Hypoalgesia in response to transcutaneous electrical nerve stimulation (TENS) depends on stimulation intensity.

    Science.gov (United States)

    Moran, Fidelma; Leonard, Tracey; Hawthorne, Stephanie; Hughes, Ciara M; McCrum-Gardner, Evie; Johnson, Mark I; Rakel, Barbara A; Sluka, Kathleen A; Walsh, Deirdre M

    2011-08-01

    Transcutaneous electrical nerve stimulation (TENS) is an electrophysical modality used for pain management. This study investigated the dose response of different TENS intensities on experimentally induced pressure pain. One hundred and thirty TENS naïve healthy individuals (18-64 years old; 65 males, 65 females) were randomly allocated to 5 groups (n = 26 per group): Strong Non Painful TENS; Sensory Threshold TENS; Below Sensory Threshold TENS; No Current Placebo TENS; and Transient Placebo TENS. Active TENS (80 Hz) was applied to the forearm for 30 minutes. Transient Placebo TENS was applied for 42 seconds after which the current amplitude automatically reset to 0 mA. Pressure pain thresholds (PPT) were recorded from 2 points on the hand and forearm before and after TENS to measure hypoalgesia. There were significant differences between groups at both the hand and forearm (ANOVA; P = .005 and .002). At 30 minutes, there was a significant hypoalgesic effect in the Strong Non Painful TENS group compared to: Below Sensory Threshold TENS, No Current Placebo TENS and Transient Placebo TENS groups (P TENS and No Current Placebo TENS groups at the hand (P = .001). There was no significant difference between Strong Non Painful TENS and Sensory Threshold TENS groups. The area under the curve for the changes in PPT significantly correlated with the current amplitude (r(2) = .33, P = .003). These data therefore show that there is a dose-response effect of TENS with the largest effect occurring with the highest current amplitudes. This study shows a dose response for the intensity of TENS for pain relief with the strongest intensities showing the greatest effect; thus, we suggest that TENS intensity should be titrated to achieve the strongest possible intensity to achieve maximum pain relief. Copyright © 2011 American Pain Society. Published by Elsevier Inc. All rights reserved.

  6. On the preparation of as-produced and purified single-walled carbon nanotube samples for standardized X-ray diffraction characterization

    International Nuclear Information System (INIS)

    Allaf, Rula M.; Rivero, Iris V.; Spearman, Shayla S.; Hope-Weeks, Louisa J.

    2011-01-01

    The aim of this research was to specify proper sample conditioning for acquiring representative X-ray diffraction (XRD) profiles for single-walled carbon nanotube (SWCNT) samples. In doing so, a specimen preparation method for quantitative XRD characterization of as-produced and purified arc-discharge SWCNT samples has been identified. Series of powder XRD profiles were collected at different temperatures, states, and points of time to establish appropriate conditions for acquiring XRD profiles without inducing much change to the specimen. It was concluded that heating in the 300-450 deg. C range for 20 minutes, preferably vacuum-assisted, and then sealing the sample is an appropriate XRD specimen preparation technique for purified arc-discharge SWCNT samples, while raw samples do not require preconditioning for characterization. - Graphical Abstract: A sample preparation method for XRD characterization of as-produced and purified arc-discharge SWCNT samples is identified. The preparation technique seeks to acquire representative XRD profiles without inducing changes to the samples. Purified samples required 20 minutes of heating at (300-450)deg. C, while raw samples did not require preconditioning for characterization. Highlights: → Purification routines may induce adsorption onto the SWCNT samples. → Heating a SWCNT sample may result in material loss, desorption, and SWCNTs closing. → Raw arc-discharge samples do not require preparation for XRD characterization. → Heating is appropriate specimen preparation for purified and heat-treated samples. → XRD data fitting is required for structural analysis of SWCNT bundles.

  7. Determination of ten carbamate pesticides in aquatic and sediment samples by liquid chromatography-ionspray and thermospray mass spectrometry.

    NARCIS (Netherlands)

    Honing, M.; Riu, J.; Barceló, D.; van Baar, B.L.M.; Brinkman, U.A.T.

    1996-01-01

    Ten carbamate pesticides which exhibit large differences in polarity were determined simultaneously in various environmental samples, using both column liquid chromatography (LC)-thermospray (TSP) mass spectrometry (MS) and LC-ionspray (ISP) MS. For sample clean-up, column chromatography with three

  8. Sampling strategies to capture single-cell heterogeneity

    OpenAIRE

    Satwik Rajaram; Louise E. Heinrich; John D. Gordan; Jayant Avva; Kathy M. Bonness; Agnieszka K. Witkiewicz; James S. Malter; Chloe E. Atreya; Robert S. Warren; Lani F. Wu; Steven J. Altschuler

    2017-01-01

    Advances in single-cell technologies have highlighted the prevalence and biological significance of cellular heterogeneity. A critical question is how to design experiments that faithfully capture the true range of heterogeneity from samples of cellular populations. Here, we develop a data-driven approach, illustrated in the context of image data, that estimates the sampling depth required for prospective investigations of single-cell heterogeneity from an existing collection of samples. ...

  9. 1-3-7 minute intravenous urography

    International Nuclear Information System (INIS)

    Bahk, Yong Whee; Yoon, Sei Chul; Lee, Myung Hee

    1980-01-01

    Intravenous urography (IVU) as it is used widely today was probably started in early 1950's after the introduction of triiodobenzoic acid compounds as contrast media. This long cherished traditional method consists of taking radiograms at 5, 15 and 25 minutes after the injection of contrast medium. There are a few modifications of this standard urographic examination such as five minute IVU (Woodruff, 1959), minute-sequence pyelogram (Maxwell et al., 1964), drip infusion pyelography (Schencker, 1964) and nephrotomography (Evans et al., 1955). The present study has been undertaken to test if the conventional standard IVU can be more rapidly performed without losing essential informational contents of urograms. In this new clinical trial, urograms were taken at the end of 1, 3 and 7 minutes instead of 5, 15 and 25 minutes after the intravenous injection of contrast medium. We injected 40 ml of meglumine diatrizoate solution within 30 seconds using an 18G iv needle. (The amount of injected contrast medium has been reduced recently to ordinary single dose of 20 ml for subjects weighing less than 8 kg). Upon viewing the 7 minute film in front of an automatic processor, the examination was terminated after obtaining an upright view unless any further radiogram was indicated. As shown in Tables and Figures, our new 1-3-7 minute method has been proven to provide us with as much essential and useful information as conventional 5-15-25 minute urography. Thus, we were able to finish one examination within 10 minutes without losing any necessary diagnostic information. In some of patients with obstructive uropathy such as stone the examination was extended as long as it was desired. Side reactions were occasional nausea, flushing and rare mild vomiting which never prevented the examination

  10. Single-sample 99mTc-diethylenetriamine penta-acetate plasma clearance in advanced renal failure by the mean sojourn time approach.

    Science.gov (United States)

    Gref, Margareta C; Karp, Kjell H

    2009-03-01

    The single-sample Tc-diethylenetriamine penta-acetate (DTPA) clearance method by Christensen and Groth is recommended by the Radionuclides in Nephrourology Committee on Renal Clearance for use in adults with an estimated glomerular filtration rate (GFR) > or = 30 ml/min. The purpose of this study was to test a new Tc-DTPA single-sample low clearance formula for GFR lesser than 30 ml/min. Twenty-one adult patients (29 investigations) were included. Reference clearance was calculated with both Cr-EDTA and Tc-DTPA according to Brøchner-Mortensen with samples drawn between 3 and 24 h. Single-sample clearance was calculated from a 24 h sample using the low clearance formula(Equation is included in full-text article.) C(t) is the activity of the tracer in the plasma sample t minutes after the injection and Q0 is the injected amount. ECV is the extracellular volume in ml defined as the distribution volume of the tracer. ECV is estimated from the body surface area as ECV=8116.6xbody surface area-28.2. The mean difference between reference and Tc-DTPA single-sample clearance was -0.5 ml/min (SD 1.0 ml/min) for Tc-DTPA and -0.8 ml/min (SD 1.2 ml/min) for Cr-EDTA as reference clearance. In adult patients it is possible, even with GFR lesser than 30 ml/min, to get an accurate determination of Tc-DTPA plasma clearance from a single sample using the mean sojourn time approach. The blood sample should be obtained about 24 h after injection of the GFR tracer.

  11. Identification and weighting factors influencing the establishment of a single minute exchange of dies in plastic injection industry using VIKOR and Shannon Entropy

    Directory of Open Access Journals (Sweden)

    Gholam Reza Hashemzadeh

    2014-05-01

    Full Text Available Single minute exchange of dies (SMED is one of the most important tools to achieve lean production system. The main idea of this system is to provide methods and to use creative and innovative solutions for continuous improvement. Due to the importance of this issue and its effect on reducing waste during the production process, this study presents a method to identify and to weight factors in the establishment of a single minute exchange of dies in 14 plastic injection factories. In this study, fourteen factories in injection industry were chosen and the factors influencing the implementation of single minute exchange of dies were identified. Following data collection, decision matrix was formed and the weight of each factor was determined by using Shannon Entropy. Then, in order to determine the readiness of factories, VIKOR method was used to rank companies. The results indicate priorities of the following factors in establishing SMED that include: Senior management support, technical capabilities, technical knowledge of staff and consultants, knowledge of mold design, manufacturing infrastructure, team work, combination of the project team work, benchmarking, training, clear understanding of project objectives, rewards and motivation, proper management expectation, project management, teamwork and organizational culture. Practical implications: Due to the factors, Top manager can make the best decision for implementing of SMED technique. This study develops factors influencing on SMED implementation based on Shannon and VIKOR methods for ranking parameters and plants.

  12. Ten-minute umbilical cord occlusion markedly reduces cerebral blood flow and heat production in fetal sheep.

    NARCIS (Netherlands)

    Lotgering, F.K.; Bishai, J.M.; Struijk, P.C.; Blood, A.B.; Hunter, C.J.; Power, G.G.; Longo, L.D.

    2003-01-01

    OBJECTIVE: The study was undertaken to determine to what extent a 10-minute total umbilical cord occlusion affects autoregulation of cerebral blood flow and cerebral heat production in the fetus. STUDY DESIGN: In seven chronically catheterized late-gestation fetal sheep (127-131 days' gestation), we

  13. [Single-layer colonic anastomoses using polyglyconate (Maxon) vs. two-layer anastomoses using chromic catgut and silk. Experimental study].

    Science.gov (United States)

    García-Osogobio, Sandra Minerva; Takahashi-Monroy, Takeshi; Velasco, Liliana; Gaxiola, Miguel; Sotres-Vega, Avelina; Santillán-Doherty, Patricio

    2006-01-01

    The safety of an intestinal anastomosis is usually measured by its complication rate, especially the incidence of anastomotic leakage. A wide variety of methods have been described to reestablish intestinal continuity including single-layer continuous or two-layer interrupted anastomosis. To evaluate if the single-layer continuous anastomosis using polygluconate is safer and reliable than two-layer interrupted anastomosis with chromic catgut and silk. A prospective, experimental, randomized and comparative analysis was conducted in 20 dogs. They were divided in two groups; group 1 underwent two-layer interrupted anastomosis and group 2 underwent sigle-layer continuous technique. Anastomoses were timed. Both groups were under observation. Anastomotic leakage, and other complications were evaluated. The animals were sacrified and the anastomosis was taken out together with 10 cm of colon on both sides of the anastomosis. Breaking strength, histologic evaluation and hydroxyproline determination were performed. Ten two-layer anastomosis and ten single-layer anastomosis were performed. A median of 25 minutes (range: 20-30 minutes) was required to construct the anastomoses in group 1 versus 20 minutes (range: 12-25 minutes) in group 2. All animals survived and no leakage was observed. Wound infection ocurred in four dogs (20%). Median breaking strength was 230 mm Hg in group 1 and 210 mm Hg in group 2. Hydroxyproline concentration was 8.94 mg/g in group 1 (range: 5.33-16.71) and 9.94 mg/g in group 2 (range: 2.96-21.87). There was no difference among groups about the inflammatory response evaluated by pathology. There was no statistical significance in any variable evaluated. CONCLUIONS: This study demonstrates that a single-layer continuous is similar in terms of safety to the two-layer technique, but because of its facility to perform, the single-layer technique could be superior.

  14. Sing, Play, and Create: All in 20 Minutes!

    Science.gov (United States)

    Mason, Emily

    2014-01-01

    Young teachers often struggle with pacing and the ability to cover more than one or two songs and activities in a single 30-minute general music class. Included in this article are lesson activities that show it is not only possible to include many of the National Standards in a single lesson, but also possible to sing, play, and create in every…

  15. Age Group Comparisons of TENS Response among Individuals with Chronic Axial Low Back Pain

    OpenAIRE

    Simon, Corey B.; Riley, Joseph L.; Fillingim, Roger B.; Bishop, Mark D.; George, Steven Z.

    2015-01-01

    Chronic low back pain (CLBP) is a highly prevalent and disabling musculoskeletal pain condition among older adults. Transcutaneous electrical nerve stimulation (TENS) is commonly used to treat CLBP, however, TENS response for older adults compared to younger adults is untested. In a dose-response study stratified by age, sixty participants with axial CLBP (20 young, 20 middle-aged, 20 older) received four 20-minute sessions of high frequency, high intensity TENS over a two to three-week perio...

  16. Pulsed Direct Current Electrospray: Enabling Systematic Analysis of Small Volume Sample by Boosting Sample Economy.

    Science.gov (United States)

    Wei, Zhenwei; Xiong, Xingchuang; Guo, Chengan; Si, Xingyu; Zhao, Yaoyao; He, Muyi; Yang, Chengdui; Xu, Wei; Tang, Fei; Fang, Xiang; Zhang, Sichun; Zhang, Xinrong

    2015-11-17

    We had developed pulsed direct current electrospray ionization mass spectrometry (pulsed-dc-ESI-MS) for systematically profiling and determining components in small volume sample. Pulsed-dc-ESI utilized constant high voltage to induce the generation of single polarity pulsed electrospray remotely. This method had significantly boosted the sample economy, so as to obtain several minutes MS signal duration from merely picoliter volume sample. The elongated MS signal duration enable us to collect abundant MS(2) information on interested components in a small volume sample for systematical analysis. This method had been successfully applied for single cell metabolomics analysis. We had obtained 2-D profile of metabolites (including exact mass and MS(2) data) from single plant and mammalian cell, concerning 1034 components and 656 components for Allium cepa and HeLa cells, respectively. Further identification had found 162 compounds and 28 different modification groups of 141 saccharides in a single Allium cepa cell, indicating pulsed-dc-ESI a powerful tool for small volume sample systematical analysis.

  17. Validation of single-sample doubly labeled water method

    International Nuclear Information System (INIS)

    Webster, M.D.; Weathers, W.W.

    1989-01-01

    We have experimentally validated a single-sample variant of the doubly labeled water method for measuring metabolic rate and water turnover in a very small passerine bird, the verdin (Auriparus flaviceps). We measured CO 2 production using the Haldane gravimetric technique and compared these values with estimates derived from isotopic data. Doubly labeled water results based on the one-sample calculations differed from Haldane values by less than 0.5% on average (range -8.3 to 11.2%, n = 9). Water flux computed by the single-sample method differed by -1.5% on average from results for the same birds based on the standard, two-sample technique (range -13.7 to 2.0%, n = 9)

  18. Creating a Positive Classroom Culture: Minute by Minute

    Science.gov (United States)

    Wright, Ali

    2014-01-01

    This article offers a peek into high school math teacher Ali Wright's typical school day, which includes time-tested strategies that she uses to build a positive culture in her classroom. Scheduled timeframes and activities include before school starts, five minutes before class, during announcements, during class, last five minutes of class,…

  19. Transcutaneous Electrical Nerve Stimulation (TENS) and Laryngeal Manual Therapy (LMT): Immediate Effects in Women With Dysphonia.

    Science.gov (United States)

    Conde, Mariana de Cásisa Macedo; Siqueira, Larissa Thaís Donalonso; Vendramini, José Eduardo; Brasolotto, Alcione Ghedini; Guirro, Rinaldo Roberto de Jesus; Silverio, Kelly Cristina Alves

    2018-05-01

    This study aimed to verify the immediate effect of low-frequency transcutaneous electrical nerve stimulation (TENS) and laryngeal manual therapy (LMT) in musculoskeletal pain, voice quality, and self-reported signs in women with dysphonia. Thirty women with behavioral dysphonia were randomly divided into the TENS group and the LMT group. All participants fulfilled the pain survey and had their voices recorded to posterior perceptual and acoustic analysis before and after intervention. The TENS group received a unique low-frequency TENS session (20 minutes). The LMT group received LMT (20 minutes) with soft and superficial massage in the sternocleidomastoid muscle, suprahyoid muscles, and larynx. Afterward, the volunteers reported their voice, larynx, breathing, and articulatory signs. Pre and post data were compared by parametric and nonparametric tests. After TENS, a decrease in pain intensity in the posterior or anterior region of the neck, shoulders, upper or lower back, and masseter was observed. After LMT, a decrease in pain intensity in the neck anterior region, shoulders, lower back, and temporal region was observed. Also, after TENS, there was an improvement in vowel /a/ instability; after LMT, there was a general improvement in voice quality, decrease in tension, and decrease in breathiness in speech. Positive voice and laryngeal signs were reported after TENS, and positive laryngeal signs and articulation were reported after LMT. TENS and LMT may be used in voice treatment of women with behavioral dysphonia, and both may be considered important therapy resources that reduce musculoskeletal pain and cause positive laryngeal signs. Both TENS and LMT are able to partially improve voice quality, but TENS presented better results. Copyright © 2018 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  20. Comparison of radon and radon-daughter grab samples obtained during the winter and summer

    International Nuclear Information System (INIS)

    Karp, K.E.

    1987-08-01

    The Technical Measurements Center (TMC), under the auspices of the US Department of Energy (DOE) Uranium Mill Tailings Remedial Action (UMTRA) program, is investigating short-term methods for estimating annual average indoor radon-daughter concentrations (RDC). A field study at 40 sample locations in 26 residential structures in Grand Junction, Colorado, was conducted once in the winter and once in the summer. The short-term methods investigated as part of this study include ten-minute radon and radon-daughter grab sampling and hourly RDC measurements. The results of the field study indicate that ten-minute radon grab samples from basement locations are reproducible over different seasons during controlled sampling conditions. Nonbasement radon and RDC grab samples are highly variable even when the use of the location by the occupant is controlled and the ventilation rate is restricted. The grab sampling was performed under controlled occupied conditions. These results confirm that a short-term radon or RDC measurement in a nonbasement location in a house is not a standardized measurement that can be used to infer an annual average concentration. The hourly RDC measurements were performed under three sets of conditions over a 72-hour period. The three sets of conditions were uncontrolled occupied, controlled occupied, and controlled unoccupied. These results indicate that it is not necessary to relocate the occupants during the time of grab sampling. 8 refs., 8 figs., 10 tabs

  1. Effects of sample treatments on genome recovery via single-cell genomics

    Energy Technology Data Exchange (ETDEWEB)

    Clingenpeel, Scott [USDOE Joint Genome Institute (JGI), Walnut Creek, CA (United States); Schwientek, Patrick [USDOE Joint Genome Institute (JGI), Walnut Creek, CA (United States); Hugenholtz, Philip [Univ. of Queensland, Brisbane (Australia); Woyke, Tanja [USDOE Joint Genome Institute (JGI), Walnut Creek, CA (United States)

    2014-06-13

    It is known that single-cell genomics is a powerful tool for accessing genetic information from uncultivated microorganisms. Methods of handling samples before single-cell genomic amplification may affect the quality of the genomes obtained. Using three bacterial strains we demonstrate that, compared to cryopreservation, lower-quality single-cell genomes are recovered when the sample is preserved in ethanol or if the sample undergoes fluorescence in situ hybridization, while sample preservation in paraformaldehyde renders it completely unsuitable for sequencing.

  2. Sampling device for withdrawing a representative sample from single and multi-phase flows

    Science.gov (United States)

    Apley, Walter J.; Cliff, William C.; Creer, James M.

    1984-01-01

    A fluid stream sampling device has been developed for the purpose of obtaining a representative sample from a single or multi-phase fluid flow. This objective is carried out by means of a probe which may be inserted into the fluid stream. Individual samples are withdrawn from the fluid flow by sampling ports with particular spacings, and the sampling parts are coupled to various analytical systems for characterization of the physical, thermal, and chemical properties of the fluid flow as a whole and also individually.

  3. Double Pass 595?nm pulsed dye laser at a 6 minute interval for the treatment of port-wine stains is not more effective than single pass

    NARCIS (Netherlands)

    Peters, M. A. D.; van Drooge, A. M.; Wolkerstorfer, A.; van Gemert, M. J. C.; van der Veen, J. P. W.; Bos, J. D.; Beek, J. F.

    2012-01-01

    Background Pulsed dye laser (PDL) is the first choice for treatment of port wine stains (PWS). However, outcome is highly variable and only a few patients achieve complete clearance. The objective of the study was to compare efficacy and safety of single pass PDL with double pass PDL at a 6 minute

  4. Area G perimeter surface-soil and single-stage water sampling: Environmental surveillance for fiscal year 94, Group ESH-19. Progress report

    International Nuclear Information System (INIS)

    Conrad, R.; Childs, M.; Lyons, C.R.; Coriz, F.

    1996-08-01

    ESH-19 personnel collected soil and single-stage water samples around the perimeter of Area G at Los Alamos National Laboratory during FY94 to characterize possible contaminant movement out of Area G through surface-water and sediment runoff. These samples were analyzed for tritium, total uranium, isotopic plutonium, americium-241, and cesium-137. Ten metals were also analyzed on selected soils using analytical laboratory techniques. All radiochemical data are compared with analogous samples collected during FY 93 and reported in LA-12986. Baseline concentrations for future disposal operations were established for metals and radionuclides by a sampling program in the proposed Area G Expansion Area. Considering the amount of radioactive waste that has been disposed at Area G, there is evidence of only low concentrations of radionuclides on perimeter surface soils. Consequently, little radioactivity is leaving the confines of Area G via the surface water runoff pathway

  5. Correlation of basic TL, OSL and IRSL properties of ten K-feldspar samples of various origins

    Energy Technology Data Exchange (ETDEWEB)

    Sfampa, I.K. [Aristotle University of Thessaloniki, Nuclear Physics Laboratory, 54124 Thessaloniki (Greece); Polymeris, G.S. [Institute of Nuclear Sciences, Ankara University, 06100 Besevler, Ankara (Turkey); Pagonis, V. [McDaniel College, Physics Department, Westminster, MD 21157 (United States); Theodosoglou, E. [Department of Mineralogy-Petrology-Economic Geology, School of Geology, Aristotle University of Thessaloniki, 54124 Thessaloniki (Greece); Tsirliganis, N.C. [Laboratory of Radiation Applications and Archaeological Dating, Department of Archaeometry and Physicochemical Measurements, ‘Athena’ R.& I.C., Kimmeria University Campus, GR67100 Xanthi (Greece); Kitis, G., E-mail: gkitis@auth.gr [Aristotle University of Thessaloniki, Nuclear Physics Laboratory, 54124 Thessaloniki (Greece)

    2015-09-15

    Highlights: • OSL and IRSL bleaching behavior of ten K-feldspar samples is presented. • OSL and IRSL decay curves were component resolved using tunneling model. • The growth of integrated OSL and IRSL signals versus time was described by new expression based on tunneling model. • Correlation between TL, OSL and IRSL signals and of all properties with K-feldspar structure was discussed. - Abstract: Feldspars stand among the most widely used minerals in dosimetric methods of dating using thermoluminescence (TL), optically stimulated luminescence (OSL) and infrared stimulated luminescence (IRSL). Having very good dosimetric properties, they can in principle contribute to the dating of every site of archaeological and geological interest. The present work studies basic properties of ten naturally occurring K-feldspar samples belonging to three feldspar species, namely sanidine, orthoclase and microcline. The basic properties studied are (a) the influence of blue light and infrared stimulation on the thermoluminescence glow-curves, (b) the growth of OSL, IRSL, residual TL and TL-loss as a function of OSL and IRSL bleaching time and (c) the correlation between the OSL and IRSL signals and the energy levels responsible for the TL glow-curve. All experimental data were fitted using analytical expressions derived from a recently developed tunneling recombination model. The results show that the analytical expressions provide excellent fits to all experimental results, thus verifying the tunneling recombination mechanism in these materials and providing valuable information about the concentrations of luminescence centers.

  6. Single-breath-hold 3-D CINE imaging of the left ventricle using Cartesian sampling.

    Science.gov (United States)

    Wetzl, Jens; Schmidt, Michaela; Pontana, François; Longère, Benjamin; Lugauer, Felix; Maier, Andreas; Hornegger, Joachim; Forman, Christoph

    2018-02-01

    Our objectives were to evaluate a single-breath-hold approach for Cartesian 3-D CINE imaging of the left ventricle with a nearly isotropic resolution of [Formula: see text] and a breath-hold duration of [Formula: see text]19 s against a standard stack of 2-D CINE slices acquired in multiple breath-holds. Validation is performed with data sets from ten healthy volunteers. A Cartesian sampling pattern based on the spiral phyllotaxis and a compressed sensing reconstruction method are proposed to allow 3-D CINE imaging with high acceleration factors. The fully integrated reconstruction uses multiple graphics processing units to speed up the reconstruction. The 2-D CINE and 3-D CINE are compared based on ventricular function parameters, contrast-to-noise ratio and edge sharpness measurements. Visual comparisons of corresponding short-axis slices of 2-D and 3-D CINE show an excellent match, while 3-D CINE also allows reformatting to other orientations. Ventricular function parameters do not significantly differ from values based on 2-D CINE imaging. Reconstruction times are below 4 min. We demonstrate single-breath-hold 3-D CINE imaging in volunteers and three example patient cases, which features fast reconstruction and allows reformatting to arbitrary orientations.

  7. Minutes

    International Nuclear Information System (INIS)

    1998-01-01

    In the minutes of II Uruguayan Geological Congress have been included the following topics: structural geology, tectonic, sedimentology, stratigraphy, mineralogy, petrology, geochemistry, paleontology, mineral prospecting, economic, regional and applied geology. (author)

  8. Sample Size Induced Brittle-to-Ductile Transition of Single-Crystal Aluminum Nitride

    Science.gov (United States)

    2015-08-01

    ARL-RP-0528 ● AUG 2015 US Army Research Laboratory Sample Size Induced Brittle-to- Ductile Transition of Single-Crystal Aluminum...originator. ARL-RP-0528 ● AUG 2015 US Army Research Laboratory Sample Size Induced Brittle-to- Ductile Transition of Single-Crystal...Sample Size Induced Brittle-to- Ductile Transition of Single-Crystal Aluminum Nitride 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT

  9. Taking minutes of meetings

    CERN Document Server

    Gutmann, Joanna

    2016-01-01

    aking Minutes of Meetings guides you through the entire process behind minute taking: arranging the meeting; writing the agenda; creating the optimum environment; structuring the meeting and writing notes up accurately. The minute-taker is one of the most important and powerful people in a meeting and you can use this opportunity to develop your knowledge, broaden your horizons and build credibility within the organization. Taking Minutes of Meetings is an easy to read 'dip-in, dip-out' guide which shows you how to confidently arrange meetings and produce minutes. It provides hands-on advice about the sections of a meeting as well as tips on how to create an agenda, personal preparation, best practice advice on taking notes and how to improve your accuracy. Brand new chapters of this 4th edition include guidance on using technology to maximize effectiveness and practical help with taking minutes for a variety of different types of meetings. The creating success series of books... With over one million copi...

  10. Effects of transcutaneous electrical nerve stimulation (TENS) and interferential currents (IFC) in patients with nonspecific chronic low back pain: randomized clinical trial.

    Science.gov (United States)

    Facci, Ligia Maria; Nowotny, Jean Paulus; Tormem, Fabio; Trevisani, Virgínia Fernandes Moça

    2011-01-01

    Transcutaneous electrical nerve stimulation (TENS) and interferential current are the most used electrotherapy methods, although there is little scientific evidence to support their use. The aim of this study was to compare the effects of TENS and interferential current among patients with nonspecific chronic low back pain. Single-blind randomized controlled trial in the Department of Physiotherapy, Centro Universitário de Maringá. One hundred and fifty patients were randomly divided into three groups: TENS (group 1), interferential current (group 2) and controls (group 3). The patients designated for electrotherapy received ten 30-minute sessions, while the control group remained untreated. All patients and controls were evaluated before and after treatment using a visual analog scale and the McGill Pain and Roland Morris questionnaires, and regarding their use of additional medications. There was a mean reduction on the visual analog scale of 39.18 mm with TENS, 44.86 mm with interferential current and 8.53 mm among the controls. In the Roland Morris questionnaire, group 1 had a mean reduction of 6.59; group 2, 7.20; and group 3, 0.70 points. In group 1, 84% of the patients stopped using medications after the treatment; in group 2, 75%; and in group 3, 34%. There was no statistically significant difference between the TENS and interferential current groups (P > 0.05); a difference was only found between these groups and the controls (P TENS and interferential current for chronic low back pain treatment. NCT01017913.

  11. High-pressure oxygenation of thin-wall YBCO single-domain samples

    International Nuclear Information System (INIS)

    Chaud, X; Savchuk, Y; Sergienko, N; Prikhna, T; Diko, P

    2008-01-01

    The oxygen annealing of ReBCO bulk material, necessary to achieve superconducting properties, usually induces micro- and macro-cracks. This leads to a crack-assisted oxygenation process that allows oxygenating large bulk samples faster than single crystals. But excellent superconducting properties are cancelled by the poor mechanical ones. More progressive oxygenation strategy has been shown to reduce drastically the oxygenation cracks. The problem then arises to keep a reasonable annealing time. The concept of bulk Y123 single-domain samples with thin-wall geometry has been introduced to bypass the inherent limitation due to a slow oxygen diffusion rate. But it is not enough. The use of a high oxygen pressure (16 MPa) enables to speed up further the process. It introduces a displacement in the equilibrium phase diagram towards higher temperatures, i.e., higher diffusion rates, to achieve a given oxygen content in the material. Remarkable results were obtained by applying such a high pressure oxygen annealing process on thin-wall single-domain samples. The trapped field of 16 mm diameter Y123 thin-wall single-domain samples was doubled (0.6T vs 0.3T at 77K) using an annealing time twice shorter (about 3 days). The initial development was made on thin bars. The advantage of thin-wall geometry is that such an annealing can be applied directly to a much larger sample

  12. Feed mechanism and method for feeding minute items

    Science.gov (United States)

    Stringer, Timothy Kent [Bucyrus, KS; Yerganian, Simon Scott [Lee's Summit, MO

    2009-10-20

    A feeding mechanism and method for feeding minute items, such as capacitors, resistors, or solder preforms. The mechanism is adapted to receive a plurality of the randomly-positioned and randomly-oriented extremely small or minute items, and to isolate, orient, and position one or more of the items in a specific repeatable pickup location wherefrom they may be removed for use by, for example, a computer-controlled automated assembly machine. The mechanism comprises a sliding shelf adapted to receive and support the items; a wiper arm adapted to achieve a single even layer of the items; and a pushing arm adapted to push the items into the pickup location. The mechanism can be adapted for providing the items with a more exact orientation, and can also be adapted for use in a liquid environment.

  13. Macroscopic, pathologic and immunologic investigations of ten patients with carcinoma of oral cavity treated by a single large dose irradiation

    International Nuclear Information System (INIS)

    Mikuriya, Shuichi; Saito, Tsutomu; Konoeda, Koichi; Igarashi, Seishi; Hirohashi, Hitoshi

    1979-01-01

    The immunosuppressive effect of radiation has been emphasized. Although the irradiated cancer cells die gradually during the treatment, it is understood that they keep cancer specific antigenecity in that process. Another words, we assume that the immunologic capacity participates in the dying process of cancer cells by radiotherapy. We have been preferring to treat carcinoma by a single large dose irradiation method because this method does not impair the patient's immunologic capacity. On this time, we treated ten patients with carcinoma of oral cavity by this method and could obtain favorable results. 1) Ten patients with carcinoma of oral cavity classified in T1N0M0-T3N0M0 were irradiated by 4 - 10 MeV betatron electron. In seven patients, 2,500 - 3,000 rads were given at once and other three patients were irradiated with fractionated dose of 1,000 rads three times within two weeks (total 3,000 rads per two weeks). 2) Effects of a single large dose irradiation were remarkable and almost all cancer cells in these patients disappeared both macroscopically and pathologically. 3) According to the results of cellular immunity tests, numbers of peripheral lymphocytes, absolute numbers of fractionated T and B cells, and blastoid formation rate of lymphocytes stimulated by PHA in vitro were all increased and values obtained by four kinds of skin tests were also elevated after the radiations. These results indicate that the single large dose irradiation for these patients does not impair the immunologic capacity of the patients. (author)

  14. "Ten Years On": Making Children Visible in Teacher Education and Ways of Reading Video

    Science.gov (United States)

    Burke, Catherine; Cunningham, Peter

    2011-01-01

    "Ten Years On" is a 30-minute video documentary discovered in the course of researching progressive primary education, school architecture and pedagogy. It was locally produced for professional rather than commercial use at a significant historical moment for educational politics and primary practice. Here, we explore the possibilities…

  15. Radiometric method for the determination of uranium in soil and air: single-laboratory evaluation and interlaboratory collaborative study

    International Nuclear Information System (INIS)

    Casella, V.R.; Bishop, C.T.; Glosby, A.A.

    1980-02-01

    Results of a single-laboratory evaluation and an interlaboratory collaborative study of a method for determining uranium isotopes in soil and air samples are presented. The method is applicable to 10-gram soil samples and to both glass fiber and polystyrene (Microsorban) air filter samples. Sample decomposition is accomplished with a nitric-hydrofluoric acid dissolution. After a solvent extraction step to remove most of the iron present, the uranium is isolated by anion exchange chromatography and electrodeposition. Alpha spectrometry is used to measure the uranium isotopes. Two soil samples, a glass fiber air filter sample, and a polystyrene air filter sample were used to evaluate the method for uranium concentrations ranging from a few tenths to about one hundred disintegrations per minute per sample. Tracer recoveries for the single-laboratory evaluation averaged 78%, while the tracer recoveries for the collaborative study averaged 66%. Although the precision of the collaborative study results did not approach counting statistics errors, the measured uranium concentrations for these samples agreed to within 5% of the reference concentrations when the uranium concentration was greater than one disintegration per minute per gram of soil or one disintegration per minute per air filter

  16. Ten year rank-order stability of personality traits and disorders in a clinical sample

    Science.gov (United States)

    Hopwood, Christopher J.; Morey, Leslie C.; Donnellan, M. Brent; Samuel, Douglas B.; Grilo, Carlos M.; McGlashan, Thomas H.; Shea, M. Tracie; Zanarini, Mary C.; Gunderson, John G.; Skodol, Andrew E.

    2012-01-01

    Objective To compare the 10-year retest stability of normal traits, pathological traits, and personality disorder dimensions in a clinical sample. Method Ten-year rank order stability estimates for the Revised NEO Personality Inventory, Schedule for Nonadaptive and Adaptive Personality, and Diagnostic Interview for DSM-IV Personality Disorders were evaluated before and after correcting for test-retest dependability and internal consistency in a clinical sample (N = 266). Results Dependability corrected stability estimates were generally in the range of .60–.90 for traits and .25–.65 for personality disorders. Conclusions The relatively lower stability of personality disorder symptoms may indicate important differences between pathological behaviors and relatively more stable self-attributed traits and imply that a full understanding of personality and personality pathology needs to take both traits and symptoms into account. The Five-Factor Theory distinction between basic tendencies and characteristic adaptations provides a theoretical framework for the separation of traits and disorders in terms of stability in which traits reflect basic tendencies that are stable and pervasive across situations, whereas personality disorder symptoms reflect characteristic maladaptations that are a function of both basic tendencies and environmental dynamics. PMID:22812532

  17. Single molecule transcription profiling with AFM

    International Nuclear Information System (INIS)

    Reed, Jason; Mishra, Bud; Pittenger, Bede; Magonov, Sergei; Troke, Joshua; Teitell, Michael A; Gimzewski, James K

    2007-01-01

    Established techniques for global gene expression profiling, such as microarrays, face fundamental sensitivity constraints. Due to greatly increasing interest in examining minute samples from micro-dissected tissues, including single cells, unorthodox approaches, including molecular nanotechnologies, are being explored in this application. Here, we examine the use of single molecule, ordered restriction mapping, combined with AFM, to measure gene transcription levels from very low abundance samples. We frame the problem mathematically, using coding theory, and present an analysis of the critical error sources that may serve as a guide to designing future studies. We follow with experiments detailing the construction of high density, single molecule, ordered restriction maps from plasmids and from cDNA molecules, using two different enzymes, a result not previously reported. We discuss these results in the context of our calculations

  18. Effects of transcutaneous electrical nerve stimulation (TENS and interferential currents (IFC in patients with nonspecific chronic low back pain: randomized clinical trial

    Directory of Open Access Journals (Sweden)

    Ligia Maria Facci

    Full Text Available CONTEXT AND OBJECTIVE: Transcutaneous electrical nerve stimulation (TENS and interferential current are the most used electrotherapy methods, although there is little scientific evidence to support their use. The aim of this study was to compare the effects of TENS and interferential current among patients with nonspecific chronic low back pain. DESIGN AND SETTING: Single-blind randomized controlled trial in the Department of Physiotherapy, Centro Universitário de Maringá. METHODS: One hundred and fifty patients were randomly divided into three groups: TENS (group 1, interferential current (group 2 and controls (group 3. The patients designated for electrotherapy received ten 30-minute sessions, while the control group remained untreated. All patients and controls were evaluated before and after treatment using a visual analog scale and the McGill Pain and Roland Morris questionnaires, and regarding their use of additional medications. RESULTS: There was a mean reduction on the visual analog scale of 39.18 mm with TENS, 44.86 mm with interferential current and 8.53 mm among the controls. In the Roland Morris questionnaire, group 1 had a mean reduction of 6.59; group 2, 7.20; and group 3, 0.70 points. In group 1, 84% of the patients stopped using medications after the treatment; in group 2, 75%; and in group 3, 34%. There was no statistically significant difference between the TENS and interferential current groups (P > 0.05; a difference was only found between these groups and the controls (P < 0.0001. CONCLUSION: There was no difference between TENS and interferential current for chronic low back pain treatment. CLINICAL TRIAL REGISTRATION: NCT01017913.

  19. Parameters of mitotic recombination in minute mutants of Drosophila melanogaster

    International Nuclear Information System (INIS)

    Ferrus, A.

    1975-01-01

    A sample of 16 Minutes, representing 12 loci distributed over all the chromosome arms and including 3 pairs of alleles and 4 deficiencies, has been studied with respect to several developmental and recombinational parameters. Cell marker mutants located in most of the chromosome arms were used to assess (1) spontaneous and x-ray-induced mitotic recombination frequencies of each Minute, and (2) clone sizes of the different cell marker clones. These parameters were analyzed both in the wing disc and in the abdominal histoblasts. Whereas spontaneous frequencies are not affected by the presence of the Minutes studied, the different Minutes characteristically increase the frequency of recombination clones arising after x irradiation. The recombinant clones which are M + /M + are significantly larger than clones in the same fly which retain the M + /M condition. This is particularly striking in clones in the wing disc, slightly so in clones in the tergites. The occurrence of mitotic recombination in the fourth chromosome is reported for the first time. Chaeta length and developmental delay correlates with the recombinational parameters in different ways. Possible causal interrelationships of the different traits of the Minute syndrome are discussed. (U.S.)

  20. Deep Vadose Zone Characterization at the Hanford Site: Accomplishments from the Last Ten Years

    International Nuclear Information System (INIS)

    Brown, Christopher F.; Serne, R. Jeffrey

    2008-01-01

    The overall goal of the Tank Farm Vadose Zone Project, led by CH2M HILL Hanford Group, Inc., is to define risks from past and future single-shell tank farm activities at Hanford. To meet this goal, CH2M HILL Hanford Group, Inc. tasked scientists from Pacific Northwest National Laboratory (PNNL) to perform detailed analyses on vadose zone sediments collected within/adjacent to the twelve single-shell tank farms contained within Hanford's Central Plateau region. This work has been performed under the Resource Conservation and Recovery Act (RCRA) Corrective Action Program and is associated with the Hanford Federal Facility Agreement and Consent Order. While there are many facets to the laboratory studies employed by PNNL, the four primary objectives of this work are to: identify the type and quantity of contamination present, understand the physical processes that affect the transport of contaminants in the vadose zone sediments, when practical, identify the source(s) of the contamination found in the sediment samples, and when practical, determine if a link can be made between the vadose zone contamination observed and any known groundwater contaminants in the vicinity. Since its inception in 1997, PNNL's Vadose Zone Characterization Project has evolved to better meet these four key objectives. The single-largest adaptation of the Vadose Zone Characterization Project over its ten years of operation was the advent of a tiered sample analysis approach. Use of a tiered approach allows resources to be focused on those samples/tests that provide the largest amount of scientific information to best meet the four key project objectives within the budget available. Another significant, but more recent, adaptation has been the implementation of a rapid turnaround characterization process in which sediment samples are analyzed in near real-time to aid drilling activities within the tank farms. This paper highlights details of the characterization activities performed as well

  1. Tip chip : Subcellular sampling from single cancer cells

    NARCIS (Netherlands)

    Quist, Jos; Sarajlic, Edin; Lai, Stanley C.S.; Lemay, Serge G.

    2016-01-01

    To analyze the molecular content of single cells, cell lysis is typically required, yielding a snapshot of cell behavior only. To follow complex molecular profiles over time, subcellular sampling methods potentially can be used, but to date these methods involve laborious offline analysis. Here we

  2. Effect of conventional TENS on pain and electromyographic activity of masticatory muscles in TMD patients Efeito da TENS convencional sobre a dor e a atividade eletromiográfica dos músculos mastigatórios em pacientes com DTM

    Directory of Open Access Journals (Sweden)

    Delaine Rodrigues

    2004-12-01

    Full Text Available Temporomandibular disorders (TMD are characterized by several signs and symptoms, such as pain and changes in the electrical activity of masticatory muscles. Considering that transcutaneous electrical nerve stimulation (TENS is a resource indicated to promote analgesia, the objective of this study was to evaluate the effect of TENS on pain and electromyographic (EMG activity of the jaw elevator muscles in TMD patients. This study evaluated 35 female volunteers: 19 TMD patients (mean age = 23.04 ± 3.5 and 16 normal subjects (mean age = 23.3 ± 3.0. Transcutaneous electrical nerve stimulation (conventional mode, 150 Hz was applied once to each group for 45 minutes. Surface electromyography (gain of 100 times and 1 kHz sampling frequency and the visual analogue scale (VAS were applied before and immediately after TENS application. Both VAS data and root mean square (RMS values were analyzed using Student's t-test. The TMD group, compared to the control group, showed higher EMG activity of the jaw elevator muscles at rest. No difference was observed between the groups regarding maximum voluntary clenching (MVC. In TMD patients, TENS reduced both pain and EMG activity of the anterior portion of the temporal muscle, increasing the activity of the masseter muscles during MVC. It is possible to conclude that a single TENS application is effective in pain reduction. However, it does not act homogeneously on the features of the electric activity of the muscles evaluated.A desordem temporomandibular (DTM é caracterizada por diversos sinais e sintomas, como dor e alteração do sinal eletromiográfico dos músculos da mastigação. Considerando que a estimulação elétrica nervosa transcutânea (TENS é um recurso indicado para promover analgesia, o objetivo deste trabalho foi avaliar o efeito da TENS na dor e na atividade eletromiográfica (EMG dos músculos elevadores da mandíbula em indivíduos com DTM. Foram selecionados 35 voluntários do sexo

  3. Data precision of X-ray fluorescence (XRF) scanning of discrete samples with the ITRAX XRF core-scanner exemplified on loess-paleosol samples

    Science.gov (United States)

    Profe, Jörn; Ohlendorf, Christian

    2017-04-01

    XRF-scanning is the state-of-the-art technique for geochemical analyses in marine and lacustrine sedimentology for more than a decade. However, little attention has been paid to data precision and technical limitations so far. Using homogenized, dried and powdered samples (certified geochemical reference standards and samples from a lithologically-contrasting loess-paleosol sequence) minimizes many adverse effects that influence the XRF-signal when analyzing wet sediment cores. This allows the investigation of data precision under ideal conditions and documents a new application of the XRF core-scanner technology at the same time. Reliable interpretations of XRF results require data precision evaluation of single elements as a function of X-ray tube, measurement time, sample compaction and quality of peak fitting. Ten-fold measurement of each sample constitutes data precision. Data precision of XRF measurements theoretically obeys Poisson statistics. Fe and Ca exhibit largest deviations from Poisson statistics. The same elements show the least mean relative standard deviations in the range from 0.5% to 1%. This represents the technical limit of data precision achievable by the installed detector. Measurement times ≥ 30 s reveal mean relative standard deviations below 4% for most elements. The quality of peak fitting is only relevant for elements with overlapping fluorescence lines such as Ba, Ti and Mn or for elements with low concentrations such as Y, for example. Differences in sample compaction are marginal and do not change mean relative standard deviation considerably. Data precision is in the range reported for geochemical reference standards measured by conventional techniques. Therefore, XRF scanning of discrete samples provide a cost- and time-efficient alternative to conventional multi-element analyses. As best trade-off between economical operation and data quality, we recommend a measurement time of 30 s resulting in a total scan time of 30 minutes

  4. Single- versus multiple-sample method to measure glomerular filtration rate.

    Science.gov (United States)

    Delanaye, Pierre; Flamant, Martin; Dubourg, Laurence; Vidal-Petiot, Emmanuelle; Lemoine, Sandrine; Cavalier, Etienne; Schaeffner, Elke; Ebert, Natalie; Pottel, Hans

    2018-01-08

    There are many different ways to measure glomerular filtration rate (GFR) using various exogenous filtration markers, each having their own strengths and limitations. However, not only the marker, but also the methodology may vary in many ways, including the use of urinary or plasma clearance, and, in the case of plasma clearance, the number of time points used to calculate the area under the concentration-time curve, ranging from only one (Jacobsson method) to eight (or more) blood samples. We collected the results obtained from 5106 plasma clearances (iohexol or 51Cr-ethylenediaminetetraacetic acid (EDTA)) using three to four time points, allowing GFR calculation using the slope-intercept method and the Bröchner-Mortensen correction. For each time point, the Jacobsson formula was applied to obtain the single-sample GFR. We used Bland-Altman plots to determine the accuracy of the Jacobsson method at each time point. The single-sample method showed within 10% concordances with the multiple-sample method of 66.4%, 83.6%, 91.4% and 96.0% at the time points 120, 180, 240 and ≥300 min, respectively. Concordance was poorer at lower GFR levels, and this trend is in parallel with increasing age. Results were similar in males and females. Some discordance was found in the obese subjects. Single-sample GFR is highly concordant with a multiple-sample strategy, except in the low GFR range (<30 mL/min). © The Author 2018. Published by Oxford University Press on behalf of ERA-EDTA. All rights reserved.

  5. Supersymmetric gauged scale covariance in ten and lower dimensions

    International Nuclear Information System (INIS)

    Nishino, Hitoshi; Rajpoot, Subhash

    2004-01-01

    We present globally supersymmetric models of gauged scale covariance in ten, six, and four dimensions. This is an application of a recent similar gauging in three dimensions for a massive self-dual vector multiplet. In ten dimensions, we couple a single vector multiplet to another vector multiplet, where the latter gauges the scale covariance of the former. Due to scale covariance, the system does not have a Lagrangian formulation, but has only a set of field equations, like Type IIB supergravity in ten dimensions. As by-products, we construct similar models in six dimensions with N=(2,0) supersymmetry, and four dimensions with N=1 supersymmetry. We finally get a similar model with N=4 supersymmetry in four dimensions with consistent interactions that have never been known before. We expect a series of descendant theories in dimensions lower than ten by dimensional reductions. This result also indicates that similar mechanisms will work for other vector and scalar multiplets in space-time lower than ten dimensions

  6. Feasibility study of Transcutaneous Electrical Nerve Stimulation (TENS) for cancer bone pain.

    Science.gov (United States)

    Bennett, Michael I; Johnson, Mark I; Brown, Sarah R; Radford, Helen; Brown, Julia M; Searle, Robert D

    2010-04-01

    This multicenter study assessed the feasibility of conducting a phase III trial of transcutaneous electrical nerve stimulation (TENS) in patients with cancer bone pain recruited from palliative care services. Eligible patients received active and placebo TENS for 1 hour at site of pain in a randomized crossover design; median interval between applications 3 days. Responses assessed at 30 and 60 minutes included numerical and verbal ratings of pain at rest and on movement, and pain relief. Recruitment, tolerability, adverse events, and effectiveness of blinding were also evaluated. Twenty-four patients were randomised and 19 completed both applications. The intervention was well tolerated. Five patients withdrew: 3 due to deteriorating performance status, and 2 due to increased pain (1 each following active and placebo TENS). Confidence interval estimation around the differences in outcomes between active and placebo TENS suggests that TENS has the potential to decrease pain on movement more than pain on rest. Nine patients did not consider that a placebo was used; the remaining 10 correctly identified placebo TENS. Feasibility studies are important in palliative care prior to undertaking clinical trials. Our findings suggest that further work is required on recruitment strategies and refining the control arm before evaluating TENS in cancer bone pain. Cancer bone pain is common and severe, and partly mediated by hyperexcitability. Animal studies suggest that Transcutaneous Electrical Nerve Stimulation can reduce hyperalgesia. This study examined the feasibility of evaluating TENS in patients with cancer bone pain in order to optimize methods before a phase III trial. Copyright 2010 American Pain Society. Published by Elsevier Inc. All rights reserved.

  7. Sub-minute method for simultaneous determination of aspartame, cyclamate, acesulfame-K and saccharin in food and pharmaceutical samples by capillary zone electrophoresis.

    Science.gov (United States)

    Vistuba, Jacqueline Pereira; Dolzan, Maressa Danielli; Vitali, Luciano; de Oliveira, Marcone Augusto Leal; Micke, Gustavo Amadeu

    2015-05-29

    This paper reports the development of a sub-minute separation method by capillary zone electrophoresis for the determination of aspartame, cyclamate, acesulfame-K and saccharin in food products and pharmaceutical samples. Separations were performed in a fused uncoated silica capillary with UV detection at 220nm. Samples and standards were injected hydrodynamically using the short-end injection procedure. The electrophoretic system was operated under constant voltage of -30kV. The background electrolyte was composed of 45mmolL(-1) 2-amino-2-(hydroxymethyl)-1,3-propanediol and 15mmolL(-1) benzoic acid at pH 8.4. The separation time for all analytes was less than 1min. Evaluation of analytical parameters of the method showed good linearity (r(2)>0.9972), limit of detection of 3.3-6.4mgL(-1), intermediate precision better than 9.75% (peak area of sample) and recovery in the range of 91-117%. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Comparative study between manual therapy and TENS Burst in patients with tension-type cephalalgia

    Directory of Open Access Journals (Sweden)

    Denise Vasconcelos Fernandes

    Full Text Available Introduction Cephalgia or cephalalgia is one of the most common symptoms in the general population. Objective To compare the efficacy of physical therapy modalities, through manual therapy and the effect of Transcutaneous Nerve Stimulation (TENS for tension-type cephalalgia. Materials and methods The study was compounded by 60 subjects, but only 40 of them completed it, due to the exclusion criteria. These were divided into control group and intervention group. The control group received treatment — manual therapy. The intervention group received TENS Burst. Patients underwent ten sessions of treatment, made at every two days on a week, lasting 30 minutes each session. Results The characteristics related to lifestyle, postural issues and range of motion are responsible for the main causes of tension-type cephalalgia. Discussion treatments showed effective results in all cases in relation to pain intensity, but the use of manual therapy techniques give the patient a better quality of life compared to the use of TENS. Final considerations The treatment of this condition deserves analysis and studies; however, there are only a few studying physical therapy techniques, especially regarding to the use of TENS.

  9. A low-temperature sample orienting device for single crystal spectroscopy at the SNS

    Energy Technology Data Exchange (ETDEWEB)

    Sherline, T E; Solomon, L; Roberts, C K II; Bruce, D; Gaulin, B; Granroth, G E, E-mail: sherlinete@ornl.gov

    2010-11-01

    A low temperature sample orientation device providing three axes of rotation has been successfully built and is in testing for use on several spectrometers at the spallation neutron source (SNS). Sample rotation about the vertical ({omega}) axis of nearly 360 deg. and out of plane tilts ({phi} and v) of from -3.4 deg. to 4.4 deg. and from -2.8 deg. to 3.5 deg., respectively, are possible. An off-the-shelf closed cycle refrigerator (CCR) is mounted on a room temperature sealed rotary flange providing {omega} rotations of the sample. Out-of-plane tilts are made possible by piezoelectric actuated angular positioning devices mounted on the low temperature head of the CCR. Novel encoding devices based on magnetoresistive sensors have been developed to measure the tilt stage angles. This combination facilitates single crystal investigations from room temperature to 3.1 K. Commissioning experiments of the rotating CCR for both powder and single crystal samples have been performed on the ARCS spectrometer at the SNS. For the powder sample this device was used to continuously rotate the sample and thus average out any partial orientation of the powder. The powder rings observed in S(Q) are presented. For the single crystal sample, the rotation was used to probe different regions of momentum transfer (Q-space). Laue patterns obtained from a single crystal sample at two rotation angles are presented.

  10. Development and implementation of a novel measure for quantifying training loads in rowing: the T2minute method.

    Science.gov (United States)

    Tran, Jacqueline; Rice, Anthony J; Main, Luana C; Gastin, Paul B

    2014-04-01

    The systematic management of training requires accurate training load measurement. However, quantifying the training of elite Australian rowers is challenging because of (a) the multicenter, multistate structure of the national program; (b) the variety of training undertaken; and (c) the limitations of existing methods for quantifying the loads accumulated from varied training formats. Therefore, the purpose of this project was to develop a new measure for quantifying training loads in rowing (the T2minute method). Sport scientists and senior coaches at the National Rowing Center of Excellence collaborated to develop the measure, which incorporates training duration, intensity, and mode to quantify a single index of training load. To account for training at different intensities, the method uses standardized intensity zones (T zones) established at the Australian Institute of Sport. Each zone was assigned a weighting factor according to the curvilinear relationship between power output and blood lactate response. Each training mode was assigned a weighting factor based on whether coaches perceived it to be "harder" or "easier" than on-water rowing. A common measurement unit, the T2minute, was defined to normalize sessions in different modes to a single index of load; one T2minute is equivalent to 1 minute of on-water single scull rowing at T2 intensity (approximately 60-72% VO2max). The T2minute method was successfully implemented to support national training strategies in Australian high performance rowing. By incorporating duration, intensity, and mode, the T2minute method extends the concepts that underpin current load measures, providing 1 consistent system to quantify loads from varied training formats.

  11. Calorimetry measurements in less than 20 minutes

    International Nuclear Information System (INIS)

    Perry, R.B.; Cremers, T.

    1991-01-01

    Argonne National Laboratory has developed a new series of 10 watt Bulk Plutonium Assay Calorimeters (BPAC10). The calorimeter measures bulk samples of plutonium bearing material in containers up to 5in. in diameter and 7in. high. The average measurement time is 19.7 minutes compared to 2--9 hours for the same sample measured in a water bath calorimeter. Measurement precision in the range of 1--10 watts is 1% to 0.1% and it is 0.010 watt for sample power less than 1 watt. BPAC10 series calorimeters are in use in two plutonium facilities at the EG ampersand G Rocky Flats Plant and at the Los Alamos National Laboratory TA55 Plutonium Facility. The paper presents a description of the calorimeter, discusses operating experience at Los Alamos, and presents a comparison of data on typical samples measured with both types of calorimeters. 5 refs., 5 figs., 1 tab

  12. Chromium-51-EDTA clearance in adults with a single-plasma sample.

    Science.gov (United States)

    Mårtensson, J; Groth, S; Rehling, M; Gref, M

    1998-12-01

    In 1996, a committee on renal clearance recommended a mean sojourn time-based methodology for single-sample determination of plasma clearance of 99mTc-diethylenetriamine pentaacetic acid (DTPA) to be used on adults if the patient's glomerular filtration rate (GFR) is suspected to be >30 ml/min. The main purpose of this study was to derive a mean sojourn time-based formula for calculation of 51Cr-ethylenediamine tetraacetic acid (EDTA) clearance in adults. Two groups of patients with 51Cr-EDTA clearance (Cl) between 16 and 172 ml/min were studied. In Group I (n = 46), reference Cl was determined as a multiplasma sample, single-injection method (ClSM). Sixteen blood samples were drawn from 0 until 5 hr after a single intravenous injection of 51Cr-EDTA. In Group II (n = 1046), reference Cl was determined by the Brøchner-Mortensen four-sample clearance method (ClBM). The plasma time-activity curves of Group I were used to derive two mean sojourn time-based formulas (Formulas 1 and 2) for calculation of a single-sample clearance. Formula 1 was derived from the entire time-activity curve, whereas the derivation of Formula 2 used only the final slope of the time-activity curve. The accuracy of the two formulas and the Christensen and Groth 99mTc-DTPA formula was tested on Group II. Chromium-51-EDTA Cl calculated by Formula 1 was almost identical to the Cl calculated by the reference Cl method (r = 0.982; SDdiff = 5.82 ml/min). Both 51Cr-EDTA Cl calculated by Formula 2 and by the 99mTc-DTPA formula showed close correlation with the reference method (r = 0.976, r = 0.985, respectively) but systematically overestimated GFR for the whole range of clearance values by 3.5 and 3.2 ml/min (ptime methodology. The determination is marginally more accurate (ptime-activity curve than from only the final slope. The single-sample formula derived for determination of 99mTc-DTPA Cl tends slightly to overestimate GFR if used to calculate 51Cr-EDTA Cl.

  13. Single-Molecule Flow Platform for the Quantification of Biomolecules Attached to Single Nanoparticles.

    Science.gov (United States)

    Jung, Seung-Ryoung; Han, Rui; Sun, Wei; Jiang, Yifei; Fujimoto, Bryant S; Yu, Jiangbo; Kuo, Chun-Ting; Rong, Yu; Zhou, Xing-Hua; Chiu, Daniel T

    2018-05-15

    We describe here a flow platform for quantifying the number of biomolecules on individual fluorescent nanoparticles. The platform combines line-confocal fluorescence detection with near nanoscale channels (1-2 μm in width and height) to achieve high single-molecule detection sensitivity and throughput. The number of biomolecules present on each nanoparticle was determined by deconvolving the fluorescence intensity distribution of single-nanoparticle-biomolecule complexes with the intensity distribution of single biomolecules. We demonstrate this approach by quantifying the number of streptavidins on individual semiconducting polymer dots (Pdots); streptavidin was rendered fluorescent using biotin-Alexa647. This flow platform has high-throughput (hundreds to thousands of nanoparticles detected per second) and requires minute amounts of sample (∼5 μL at a dilute concentration of 10 pM). This measurement method is an additional tool for characterizing synthetic or biological nanoparticles.

  14. A Fully-Integrated MEMS Preconcentrator for Rapid Gas Sampling (Preprint)

    National Research Council Canada - National Science Library

    Bae, Byunghoon; Yeom, Junghoon; Radadia, Adarsh D; Masel, Richard I; Shannon, Mark A

    2006-01-01

    .... The unprecedented speed of this preconcentrator (chemical warfare agents, toxic industrial compounds (TICs), and other volatile compounds in seconds, rather than tens of minutes with conventional systems.

  15. [Comparison of the analgesic effect of interferential current (IFC) and TENS in patients with low back pain].

    Science.gov (United States)

    Grabiańska, Ewa; Leśniewicz, Joanna; Pieszyński, Ireneusz; Kostka, Joanna

    2015-01-01

    Electrotherapy, including theTENS and interferential current (IFC) is one of the most frequently used treatments in physical therapy in patients with low back pain. The aim of this study was to assess the influence of TENS and IFC on pain relief and to compare the analgesic efficacy of the two currents. Sixty patients aged 53.5 ± 12.5, with low back pain, were randomly divided into two groups: IFC (gr. I) and TENS (gr. II). Depending on the groups, patients were given series of ten 20-minute sessions using either IF orTENS currents. In all patients VAS and Laitinen modified scale were taken before and after treatment. After 2-weeks therapy there was improvement in the VAS and Laitinen scale (all components) in both groups, except for the part of the Laitinen scale on the reduction of activity in the group II (TENS). There was no statistically significant difference between the TENS and IF groups in reducing the intensity and other aspects of pain (frequency, pain medication and activity limitation) under the influence of therapy (p > 0.05). Interferential current and TENS therapy are effective for pain relief in patients with low back pain. The study showed equal analgesic efficacy of both treatments.

  16. Open heart surgery with deep hypothermic cardiopulmonary bypass and more than 90 minutes of aortic cross clamp time in 10 small dogs

    Directory of Open Access Journals (Sweden)

    Kippei Mihara

    2017-04-01

    Full Text Available No previous reports have described cardiopulmonary bypass (CPB techniques involving long aortic cross clamp (ACC times in small-breed dogs. We previously described open heart surgery under deep hypothermic CPB in small and toy dogs with an approximate ACC time limit of 1 hour, given the low success rate beyond 90 minutes of ACC time. Herein, we describe improvements in cardiac anesthesia, CPB, and cardioplegia that led to a high success rate of open heart surgery with a long ACC time in small dogs. Ten small-breed dogs with severe mitral regurgitation were subjected to mitral valve plasty that necessitated cardiopulmonary bypass (CPB beyond 90 minutes of ACC time. In the present study, all dogs survived surgery; 7 survived to discharge. In other words, we achieved a high success rate of 70% with mitral valve plasty beyond 90 minutes of ACC time (mean, 105.1 minutes: range, 90-117 minutes. For small dogs, successful open heart surgery with a long ACC time may require cardiac balanced anesthesia, CPB with increased drainage and, importantly, thorough cardioplegia without hemodilution.

  17. Vapor and gas sampling of single-shell tank 241-BX-110 using the in situ vapor sampling system

    International Nuclear Information System (INIS)

    Lockrem, L.L.

    1997-01-01

    The Vapor Issue Resolution Program tasked the Vapor Team (the team) to collect representative headspace samples from Hanford Site single-shell tank (SST) 241-BX-110. This document presents sampling data resulting from the April 30, 1996 sampling of SST 241-BX-110. Analytical results will be presented in a separate report issued by Pacific Northwest National Laboratory (PNNL), which supplied and analyzed the sampling media

  18. A comparison between over-the-head and lateral cardiopulmonary resuscitation with a single rescuer by bag-valve mask

    Directory of Open Access Journals (Sweden)

    Ebrahim Nasiri

    2014-01-01

    Full Text Available Context: mask fixation in the lateral position is difficult during CPR. Aim: the aim of this study is to compare the lateral CPR for the use of bag-valve mask by single paramedic rescuer as well as over-the-head CPR on the chest compression and ventilation on the manikin. Settings and Design: Mazandaran University of Medical Sciences. The design of this study was a randomized cross-over trial. Methods: participants learned a standardized theoretical introduction CPR according to the 2010 guidelines. The total number of chest compressions per two minutes was measured. Total number of correct and wrong ventilation per two minutes was evaluated. Statistical Analysis: we used Wilcoxon signed-rank test to analyze the non-normally distributed data in dependence groups A. P-value of more than 0.05 was considered to show statistical significance. Results: there were 100 participants (45 women and 55 men who participated in the study from September to March, 2011. The compression and ventilation rate in lateral CPR was lower than OTH CPR. Around 51% of participants had correct chest compression rate more than 90 beats per minute in lateral CPR and 65% of them had equal or more than ten correct ventilations per minute. Conclusions: in conclusion, this study confirmed that in a simulated CPR model over-the-head position CPR led to a better BLS than the lateral position CPR by a single paramedic student with a BVM device. We also concluded that by this new BVM fixation method on the face of the patients in the lateral position CPR can be a good alternative over-the-head mask fixation by a single trained rescuer.

  19. Vapor and gas sampling of single-shell tank 241-U-104 using the in situ vapor sampling system

    International Nuclear Information System (INIS)

    Lockrem, L.L.

    1997-01-01

    The Vapor Issue.Resolution Program tasked the Vapor Team (VT) to collect representative headspace samples from Hanford Site single-shell tank (SST) 241-U-104. This document presents In Situ Vapor Sampling System (ISVS) data resulting from the July 16, 1996 sampling of SST 241-U-104. Analytical results will be presented in separate reports issued by the Pacific Northwest National Laboratory (PNNL) which supplied and analyzed the sample media

  20. Vapor and gas sampling of single-shell tank 241-S-103 using the in situ vapor sampling system

    International Nuclear Information System (INIS)

    Lockrem, L.L.

    1997-01-01

    The Vapor Issue Resolution Program tasked the Vapor Team (VT) to collect representative headspace samples from Hanford Site single-shell tank (SST) 241-S-103. This document presents In Situ Vapor Sampling System (ISVS) data resulting from the June 12, 1996 sampling of SST 241-S-103. Analytical results will be presented in separate reports issued by the Pacific Northwest National Laboratory (PNNL) which supplied and analyzed the sample media

  1. Vapor and gas sampling of single-shell tank 241-S-106 using the in situ vapor sampling system

    International Nuclear Information System (INIS)

    Lockrem, L.L.

    1997-01-01

    The Vapor Issue Resolution Program tasked the Vapor Team (VT) to collect representative headspace samples from Hanford Site single-shell tank (SST) 241-S-106. This document presents In Situ vapor Sampling System (ISVS) data resulting from the June 13, 1996 sampling of SST 241-S-106. Analytical results will be presented in separate reports issued by the Pacific Northwest National Laboratory (PNNL) which'supplied and analyzed the sample media

  2. Near bed suspended sediment flux by single turbulent events

    Science.gov (United States)

    Amirshahi, Seyed Mohammad; Kwoll, Eva; Winter, Christian

    2018-01-01

    The role of small scale single turbulent events in the vertical mixing of near bed suspended sediments was explored in a shallow shelf sea environment. High frequency velocity and suspended sediment concentration (SSC; calibrated from the backscatter intensity) were collected using an Acoustic Doppler Velocimeter (ADV). Using quadrant analysis, the despiked velocity time series was divided into turbulent events and small background fluctuations. Reynolds stress and Turbulent Kinetic Energy (TKE) calculated from all velocity samples, were compared to the same turbulent statistics calculated only from velocity samples classified as turbulent events (Reevents and TKEevents). The comparison showed that Reevents and TKEevents was increased 3 and 1.6 times, respectively, when small background fluctuations were removed and that the correlation with SSC for TKE could be improved through removal of the latter. The correlation between instantaneous vertical turbulent flux (w ‧) and SSC fluctuations (SSC ‧) exhibits a tidal pattern with the maximum correlation at peak ebb and flood currents, when strong turbulent events appear. Individual turbulent events were characterized by type, strength, duration and length. Cumulative vertical turbulent sediment fluxes and average SSC associated with individual turbulent events were calculated. Over the tidal cycle, ejections and sweeps were the most dominant events, transporting 50% and 36% of the cumulative vertical turbulent event sediment flux, respectively. Although the contribution of outward interactions to the vertical turbulent event sediment flux was low (11%), single outward interaction events were capable of inducing similar SSC ‧ as sweep events. The results suggest that on time scales of tens of minutes to hours, TKE may be appropriate to quantify turbulence in sediment transport studies, but that event characteristics, particular the upward turbulent flux need to be accounted for when considering sediment transport

  3. Keys to success: Ten case studies of effective weatherization programs

    Energy Technology Data Exchange (ETDEWEB)

    Brown, M.A.; Berry, L.G.; Kolb, J.O.; White, D.L. [Oak Ridge National Lab., TN (United States); Kinney, L.F.; Wilson, T. [Synertech Systems Corp., Syracuse, NY (United States)

    1993-11-01

    In 1990, DOE initiated a nationwide evaluation of its Weatherization Program, with assistance from Oak Ridge National Laboratory and an advisory group of 40 weatherization professionals, program managers, and researchers. The evaluation is comprised of three impact studies covering the Program`s major market segments: Single-family homes, mobile homes, and dwellings in small (2 to 4-unit) multifamily buildings (the Single-Family Study), Single-family homes heated primarily with fuel oil (the Fuel-Oil Study), and Dwellings in buildings with five or more units (the Multifamily Study). The Single-Family Study, the subject of this report, is a critical part of this coordinated evaluation effort. Its focus on single-family dwellings, mobile homes, and dwellings in small multifamily buildings covers 83% of the income-eligible population and 96% of the dwellings weatherized during Program Year 1989. The first phase of the Single-Family Study involved the analysis of a massive data base of information collected from 368 local weatherization agencies and 543 electric and gas utilities. This analysis resulted in energy-saving and cost-effectiveness estimates for the Weatherization Program and the identification of a set of ten high-performing agencies located throughout the country. The second phase, which is the subject of this report, involves a ``process`` evaluation of these ten high performers, aimed at identifying those weatherization practices that explain their documented success.

  4. An investigation into the effects of frequency-modulated transcutaneous electrical nerve stimulation (TENS) on experimentally-induced pressure pain in healthy human participants.

    Science.gov (United States)

    Chen, Chih-Chung; Johnson, Mark I

    2009-10-01

    Frequency-modulated transcutaneous electrical nerve stimulation (TENS) delivers currents that fluctuate between preset boundaries over a fixed period of time. This study compared the effects of constant-frequency TENS and frequency-modulated TENS on blunt pressure pain in healthy human volunteers. Thirty-six participants received constant-frequency TENS (80 pps), frequency-modulated TENS (20 to 100 pps), and placebo (no current) TENS at a strong nonpainful intensity in a randomized cross-over manner. Pain threshold was taken from the forearm using pressure algometry. There were no statistical differences between constant-frequency TENS and frequency-modulated TENS after 20 minutes (OR = 1.54; CI, 0.29, 8.23, P = 1.0). Both constant-frequency TENS and frequency-modulated TENS were superior to placebo TENS (OR = 59.5, P TENS does not influence hypoalgesia to any greater extent than constant-frequency TENS when currents generate a strong nonpainful paraesthesia at the site of pain. The finding that frequency-modulated TENS and constant-frequency TENS were superior to placebo TENS provides further evidence that a strong yet nonpainful TENS intensity is a prerequisite for hypoalgesia. This study provides evidence that TENS, delivered at a strong nonpainful intensity, increases pain threshold to pressure algometry in healthy participants over and above that seen with placebo (no current) TENS. Frequency-modulated TENS does not increase hypoalgesia to any appreciable extent to that seen with constant-frequency TENS.

  5. Age Group Comparisons of TENS Response Among Individuals With Chronic Axial Low Back Pain.

    Science.gov (United States)

    Simon, Corey B; Riley, Joseph L; Fillingim, Roger B; Bishop, Mark D; George, Steven Z

    2015-12-01

    Chronic low back pain (CLBP) is a highly prevalent and disabling musculoskeletal pain condition among older adults. Transcutaneous electrical nerve stimulation (TENS) is commonly used to treat CLBP, however response to TENS in older adults compared with younger adults is untested. In a dose-response study stratified by age, 60 participants with axial CLBP (20 young, 20 middle-aged, 20 older) received four 20-minute sessions of high-frequency high-intensity TENS over a 2- to 3-week period in a laboratory-controlled setting. Experimental measures of pain sensitivity (mechanical pressure pain detection threshold) and central pain excitability (phasic heat temporal summation and heat aftersensations) were assessed before and after TENS. Episodic or immediate axial CLBP relief was assessed after TENS via measures of resting pain, movement-evoked-pain, and self-reported disability. Cumulative or prolonged axial CLBP relief was assessed by comparing daily pain reports across sessions. Independent of age, individuals experienced episodic increase in the pressure pain detection threshold and reduction in aftersensation after TENS application. Similarly, all groups, on average, experienced episodic axial CLBP relief via improved resting pain, movement-evoked pain, and disability report. Under this design, no cumulative effect was observed as daily pain did not improve for any age group across the 4 sessions. However, older adults received higher TENS amplitude across all sessions to achieve TENS responses similar to those in younger adults. These findings suggest that older adults experience similar episodic axial CLBP relief to that of younger individuals after high-frequency, high-intensity TENS when higher dose parameters are used. This study examined age group differences in experimental and axial CLBP response to TENS, delivered under the current recommended parameters of strong, but tolerable amplitude. Older adults had comparable TENS response although at higher TENS

  6. Reliability and feasibility of the six minute walk test in subjects with myotonic dystrophy.

    Science.gov (United States)

    Kierkegaard, Marie; Tollbäck, Anna

    2007-12-01

    The objective was to describe test-retest reliability and feasibility of the six minute walk test in adult subjects with myotonic dystrophy type 1. Twelve subjects (28-68 years, mean 44) performed three six minute walk tests on two occasions, one week apart. Relative reliability was high (ICC(2.1)=0.99) and absolute reliability values were low (standard error of measurement 12 m, repeatability 33 m). Feasibility was investigated in a sample of 64 subjects (19-70 years, mean 43). Fifty-two subjects were able to perform two tests on the same day. Subjects with severe proximal weakness had difficulties performing repeated tests. A practice trial followed by a second test on the same day can be recommended for most subjects, and the best test should be used for evaluations. In conclusion, even though the study sample was small, the present study indicates that the six minute walk test is reliable and feasible in subjects with myotonic dystrophy type 1.

  7. Treatment of Idiopathic Chronic Orchialgia with Transcutaneous Electrical Nerve Stimulation (TENS:A Preliminary Result

    Directory of Open Access Journals (Sweden)

    Ekrem Akdeniz

    2016-01-01

    Full Text Available Purpose: Unilateral or bilateral testicular pain lasting more than 3 months is called as chronic orchialgia. Aproximately 25-50% of chronic orchialgia is idiopatic origin. This study aimed the effectiveness of Transcutaneous Electrical Nerve Stimulation (TENS therapy due to Idiopathic Chronic Orchialgia (ICO. Methods: Five patients were included into this study with ICO that diagnosed with physical examination, urine analyses, urinary system x-ray film, and scrotal doppler ultrasound. Medical history revealed that multiple conservative therapy attempts failed to alleviate the pain. Two of the patients had right sided ICO. Traditional TENS device is placed to the most painful points. TENS applied 3 times in a week with duration 30 minutes for 4 weeks. Before and after TENS application, patients were evaluated by using Visual Analog Scale (VAS at first and third months. Results: Median age of patients was 26.20±2.38 (22-30. Mean VAS value was 6.52 ± 0.89 before the procedure. After 1 month VAS value was 3.82 ± 0.83 (p0.05. None of the patients needed any analgesics after during the one month. No complications, hyperemia or hypoesthesia of the scrotal or penile skin, occurred after the procedure. Conclusion: TENS reduces pain by increasing endorphin release in the spinal cord dorsal horn. TENS is very effective method for first 1 month in patients with ICO but its effect reduces by the time. There is no standard therapeutic protocol for idiopathic chronic orchialgia. Therefore TENS may be an alternative for patients who do not benefit from medical therapy and do not want invasive procedures. Short-term use of TENS and low number of the patients are the limitations of this study. Randomized, placebo-controlled, and longer follow-up period studies are needed to better assess the efficacy of TENS for ICO.

  8. Genomic Sequencing of Single Microbial Cells from Environmental Samples

    Energy Technology Data Exchange (ETDEWEB)

    Ishoey, Thomas; Woyke, Tanja; Stepanauskas, Ramunas; Novotny, Mark; Lasken, Roger S.

    2008-02-01

    Recently developed techniques allow genomic DNA sequencing from single microbial cells [Lasken RS: Single-cell genomic sequencing using multiple displacement amplification, Curr Opin Microbiol 2007, 10:510-516]. Here, we focus on research strategies for putting these methods into practice in the laboratory setting. An immediate consequence of single-cell sequencing is that it provides an alternative to culturing organisms as a prerequisite for genomic sequencing. The microgram amounts of DNA required as template are amplified from a single bacterium by a method called multiple displacement amplification (MDA) avoiding the need to grow cells. The ability to sequence DNA from individual cells will likely have an immense impact on microbiology considering the vast numbers of novel organisms, which have been inaccessible unless culture-independent methods could be used. However, special approaches have been necessary to work with amplified DNA. MDA may not recover the entire genome from the single copy present in most bacteria. Also, some sequence rearrangements can occur during the DNA amplification reaction. Over the past two years many research groups have begun to use MDA, and some practical approaches to single-cell sequencing have been developed. We review the consensus that is emerging on optimum methods, reliability of amplified template, and the proper interpretation of 'composite' genomes which result from the necessity of combining data from several single-cell MDA reactions in order to complete the assembly. Preferred laboratory methods are considered on the basis of experience at several large sequencing centers where >70% of genomes are now often recovered from single cells. Methods are reviewed for preparation of bacterial fractions from environmental samples, single-cell isolation, DNA amplification by MDA, and DNA sequencing.

  9. Implementation fidelity of self-administered transcutaneous electrical nerve stimulation (TENS) in patients with chronic back pain: an observational study.

    Science.gov (United States)

    Pallett, Edward J; Rentowl, Patricia; Johnson, Mark I; Watson, Paul J

    2014-03-01

    The efficacy of transcutaneous electrical nerve stimulation (TENS) for pain relief has not been reliably established. Inconclusive findings could be due to inadequate TENS delivery and inappropriate outcome assessment. Electronic monitoring devices were used to determine patient compliance with a TENS intervention and outcome assessment protocol, to record pain scores before, during, and after TENS, and measure electrical output settings. Patients with chronic back pain consented to use TENS daily for 2 weeks and to report pain scores before, during, and after 1-hour treatments. A ≥ 30% reduction in pain scores was used to classify participants as TENS responders. Electronic monitoring devices "TLOG" and "TSCORE" recorded time and duration of TENS use, electrical settings, and pain scores. Forty-two patients consented to participate. One of 35 (3%) patients adhered completely to the TENS use and pain score reporting protocol. Fourteen of 33 (42%) were TENS responders according to electronic pain score data. Analgesia onset occurred within 30 to 60 minutes for 13/14 (93%) responders. It was not possible to correlate TENS amplitude, frequency, or pulse width measurements with therapeutic response. Findings from TENS research studies depend on the timing of outcome assessment; pain should be recorded during stimulation. TENS device sophistication might be an issue and parameter restriction should be considered. Careful protocol design is required to improve adherence and monitoring is necessary to evaluate the validity of findings. This observational study provides objective evidence to support concerns about poor implementation fidelity in TENS research.

  10. Topical Articles: Attention during Lectures--Beyond Ten Minutes

    Science.gov (United States)

    Wilson, Karen; Korn, James H.

    2007-01-01

    Many authors claim that students' attention declines approximately 10 to 15 min into lectures. To evaluate this claim, we reviewed several types of studies including studies of student note taking, observations of students during lectures, and self-reports of student attention, as well as studies using physiological measures of attention. We found…

  11. School Psychologists' Job Satisfaction: Ten Years Later

    OpenAIRE

    Worrell, Travis G.

    2004-01-01

    School Psychologistsâ Job Satisfaction: Ten Years Later (ABSTRACT) This study was designed to replicate nationwide surveys completed in 1982 and 1992. The purpose was to examine and describe the levels of job satisfaction and the relationship between the variables in a national sample of school psychologists belonging to the National Association of School Psychologists (NASP). The sample for this study consisted of respondents who reported being full-time school practitioners. ...

  12. Vapor and gas sampling of single-shell tank 241-B-102 using the in situ vapor sampling system

    International Nuclear Information System (INIS)

    Lockrem, L.L.

    1997-01-01

    The Vapor Issue Resolution Program tasked the Vapor Team (the team) to collect representative headspace samples from Hanford Site single-shell tank (SST) 241-B-102. This document presents sampling data resulting from the April 18, 1996 sampling of SST 241-B-102. Analytical results will be presented in a separate report issued by Pacific Northwest National Laboratory (PNNL), which supplied and analyzed the sampling media. The team, consisting of Sampling and Mobile Laboratories (SML) and Special Analytical Studies (SAS) personnel, used the vapor sampling system (VSS) to collect representative samples of the air, gases, and vapors from the headspace of SST 241-B-102 with sorbent traps and SUMMA canisters

  13. Optimization of single plate-serial dilution spotting (SP-SDS) with sample anchoring as an assured method for bacterial and yeast cfu enumeration and single colony isolation from diverse samples.

    Science.gov (United States)

    Thomas, Pious; Sekhar, Aparna C; Upreti, Reshmi; Mujawar, Mohammad M; Pasha, Sadiq S

    2015-12-01

    We propose a simple technique for bacterial and yeast cfu estimations from diverse samples with no prior idea of viable counts, designated as single plate-serial dilution spotting (SP-SDS) with the prime recommendation of sample anchoring (10 0 stocks). For pure cultures, serial dilutions were prepared from 0.1 OD (10 0 ) stock and 20 μl aliquots of six dilutions (10 1 -10 6 ) were applied as 10-15 micro-drops in six sectors over agar-gelled medium in 9-cm plates. For liquid samples 10 0 -10 5 dilutions, and for colloidal suspensions and solid samples (10% w/v), 10 1 -10 6 dilutions were used. Following incubation, at least one dilution level yielded 6-60 cfu per sector comparable to the standard method involving 100 μl samples. Tested on diverse bacteria, composite samples and Saccharomyces cerevisiae , SP-SDS offered wider applicability over alternative methods like drop-plating and track-dilution for cfu estimation, single colony isolation and culture purity testing, particularly suiting low resource settings.

  14. Assessing the validity of single-item life satisfaction measures: results from three large samples.

    Science.gov (United States)

    Cheung, Felix; Lucas, Richard E

    2014-12-01

    The present paper assessed the validity of single-item life satisfaction measures by comparing single-item measures to the Satisfaction with Life Scale (SWLS)-a more psychometrically established measure. Two large samples from Washington (N = 13,064) and Oregon (N = 2,277) recruited by the Behavioral Risk Factor Surveillance System and a representative German sample (N = 1,312) recruited by the Germany Socio-Economic Panel were included in the present analyses. Single-item life satisfaction measures and the SWLS were correlated with theoretically relevant variables, such as demographics, subjective health, domain satisfaction, and affect. The correlations between the two life satisfaction measures and these variables were examined to assess the construct validity of single-item life satisfaction measures. Consistent across three samples, single-item life satisfaction measures demonstrated substantial degree of criterion validity with the SWLS (zero-order r = 0.62-0.64; disattenuated r = 0.78-0.80). Patterns of statistical significance for correlations with theoretically relevant variables were the same across single-item measures and the SWLS. Single-item measures did not produce systematically different correlations compared to the SWLS (average difference = 0.001-0.005). The average absolute difference in the magnitudes of the correlations produced by single-item measures and the SWLS was very small (average absolute difference = 0.015-0.042). Single-item life satisfaction measures performed very similarly compared to the multiple-item SWLS. Social scientists would get virtually identical answer to substantive questions regardless of which measure they use.

  15. Effect of a single gemfibrozil dose on the pharmacokinetics of rosuvastatin in bile and plasma in healthy volunteers.

    Science.gov (United States)

    Bergman, Ebba; Matsson, Elin M; Hedeland, Mikael; Bondesson, Ulf; Knutson, Lars; Lennernäs, Hans

    2010-09-01

    The effect of a single intrajejunal dose of gemfibrozil (600 mg) on the plasma pharmacokinetics and biliary excretion of a single intrajejunal dose of rosuvastatin (20 mg) was investigated by using a multichannel catheter positioned in the distal duodenum-proximal jejunum in 8 healthy volunteers. Bile and plasma samples were collected every 20 minutes for 200 minutes, with additional plasma samples being drawn for up to 48 hours. Gemfibrozil did not affect the bioavailability of rosuvastatin, although it increased the apparent absorption phase during the initial 200 minutes (AUC(plasma,200min)) by 1.56-fold (95% confidence interval, 1.14-2.15). The interaction was less pronounced in this single-dose study than in a previous report when gemfibrozil was administered repeatedly; nevertheless, the interaction coincided with the highest exposure to gemfibrozil. The plausible reason why the interaction in this investigation was only minor is the low exposure to gemfibrozil (and its metabolites), suggesting that the total plasma concentration of gemfibrozil needs to be above 20 µM to affect the disposition of rosuvastatin. This study demonstrates the value of monitoring the plasma pharmacokinetics of the inhibitor, and not only the drug under investigation, to improve the mechanistic interpretation.

  16. 2 minute Southcentral Alaska Elevation Grid

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The 2-minute Southcentral Alaska Elevation Grid provides bathymetric data in ASCII raster format of 2-minute resolution in geographic coordinates. This grid is...

  17. USE OF SINGLE-MINUTE EXCHANGE OF DIE – SMED – AS A STRATEGY TO INCREASE PRODUCTIVITY IN A PLASTIC BOTTLE LABELER

    Directory of Open Access Journals (Sweden)

    Teonas Bartz

    2012-12-01

    Full Text Available The increase in the production and sale of food products stored in plastic containers, which serve different markets, caused the company researched departed in search of new concepts to increase the productivity of production equipment. With the increase of productivity, there is greater flexibility in planning and scheduling of production and exchange of tools. The implementation of the methodology of Single-Minute Exchange of Die – SMED reduces the setup time of equipment, maximizing the period of machine operation. With this the company more flexible production process and can reduce production batches, increasing operating rates, productivity and competitiveness of organizations. In this paper, we present the steps necessary for the implementation of the SMED in a labeling machine for plastic bottles. To this end, there were activities analysis, suggestions for improvements in machinery and procedures, timing of the steps before and after the improvements implemented and analyzes of the times obtained. After that, we obtained a significant reduction in setup time machine studied.

  18. Effect of transcutaneous electric nerve stimulation (TENS on hormones profile in subjects with primary dysmenorrhoea - a preliminary study

    Directory of Open Access Journals (Sweden)

    S. R. A. Akinbo

    2007-01-01

    as the occurrence of painful menstrual cramps of uterine origin which occurs in the absence of any underlying disease. The pathogenesis is unclear, but uterine hyperactivity, elevated prostaglandin and leukotrienes levels, and hormonal level fluctuations have all been implicated. The objective of this study was to evaluate the effect of TENS on the hormones cortisol and prolactin in individuals with PD. Methods: Plasma levels of cortisol and prolactin were studied in twenty-one (21 subjects with PD by obtaining blood samples from each subject pre-and post-TENS therapy on the first day of menstruation. The mean age of subjects was 23 (+ 2 years.  The Visual Analogue Scale (VAS was used to assess the pre-and post-treatment pain intensity.  The TENS unit was applied for a duration of 30 minutes. Results: A paired t-test showed that there was an overall reduction in the mean cortisol and prolactin from  pre treatment values of 28.45µg/dl ((5.27 and 56.81ng/ml ((31.86 to post treatment values of 27.33µg/dl ((5.13 and 53.23ng/ml ((37.63 respectively. However, these differences were not statistically significant (P>0.05.  Pain intensity was significantly reduced comparing pre and post treatment VAS scores (P = 0.001. Conclusion: The probable mechanism by which TENS effected alterations in cortisol and prolactin levels and pain reduction in subjects with PD might be through the opioid-modulating analgesia system, which releases B-endorphins and other endogenous opiates in response to pain.  This is because there is a close relationship between B-endorphin, cortisol and neurons, which secrete dopamine into the hypothalamic-pituitary-portal system.

  19. A Single Platinum Microelectrode for Identifying Soft Drink Samples

    Directory of Open Access Journals (Sweden)

    Lígia Bueno

    2012-01-01

    Full Text Available Cyclic voltammograms recorded with a single platinum microelectrode were used along with a non-supervised pattern recognition, namely, Principal Component Analysis, to conduct a qualitative analysis of sixteen different brands of carbonated soft drinks (Kuat, Soda Antarctica, H2OH!, Sprite 2.0, Guarana Antarctica, Guarana Antarctica Zero, Coca-Cola, Coca-Cola Zero, Coca-Cola Plus, Pepsi, Pepsi Light, Pepsi Twist, Pepsi Twist Light, Pepsi Twist 3, Schin Cola, and Classic Dillar’s. In this analysis, soft drink samples were not subjected to pre-treatment. Good differentiation among all the analysed soft drinks was achieved using the voltammetric data. An analysis of the loading plots shows that the potentials of −0.65 V, −0.4 V, 0.4 V, and 0.750 V facilitated the discrimination process. The electrochemical processes related to this potential are the reduction of hydrogen ions and inhibition of the platinum oxidation by the caffeine adsorption on the electrode surface. Additionally, the single platinum microelectrode was useful for the quality control of the soft drink samples, as it helped to identify the time at which the beverage was opened.

  20. A Study in Critical Listening Using Eight to Ten Year Olds in an Analysis of Commercial Propaganda Emanating from Television.

    Science.gov (United States)

    Cook, Jimmie Ellis

    Selected eight to ten year old Maryland children were used in this study measuring the effect of lessons in becoming aware of propaganda employed by commercial advertisers in television programs. Sixteen 45-minute lessons directed to the propaganda techniques of Band Wagon, Card Stacking, Glittering Generalities, Name Calling, Plain Folks,…

  1. Assessing the Validity of Single-item Life Satisfaction Measures: Results from Three Large Samples

    Science.gov (United States)

    Cheung, Felix; Lucas, Richard E.

    2014-01-01

    Purpose The present paper assessed the validity of single-item life satisfaction measures by comparing single-item measures to the Satisfaction with Life Scale (SWLS) - a more psychometrically established measure. Methods Two large samples from Washington (N=13,064) and Oregon (N=2,277) recruited by the Behavioral Risk Factor Surveillance System (BRFSS) and a representative German sample (N=1,312) recruited by the Germany Socio-Economic Panel (GSOEP) were included in the present analyses. Single-item life satisfaction measures and the SWLS were correlated with theoretically relevant variables, such as demographics, subjective health, domain satisfaction, and affect. The correlations between the two life satisfaction measures and these variables were examined to assess the construct validity of single-item life satisfaction measures. Results Consistent across three samples, single-item life satisfaction measures demonstrated substantial degree of criterion validity with the SWLS (zero-order r = 0.62 – 0.64; disattenuated r = 0.78 – 0.80). Patterns of statistical significance for correlations with theoretically relevant variables were the same across single-item measures and the SWLS. Single-item measures did not produce systematically different correlations compared to the SWLS (average difference = 0.001 – 0.005). The average absolute difference in the magnitudes of the correlations produced by single-item measures and the SWLS were very small (average absolute difference = 0.015 −0.042). Conclusions Single-item life satisfaction measures performed very similarly compared to the multiple-item SWLS. Social scientists would get virtually identical answer to substantive questions regardless of which measure they use. PMID:24890827

  2. Study on Association between Single Nucleotide Polymorphisms in Murine Double Minute 2 and Susceptibility of Hepatocellular Carcinoma

    Directory of Open Access Journals (Sweden)

    Xia Wang

    2014-03-01

    Full Text Available Objective: To investigate the relationship between single nucleotide polymorphisms (SNP in murine double minute 2 (MDM2 and susceptibility and biological behavior of hepatocellularcarcinoma (HCC. Methods: MDM2 (rs2279744 site polymorphism in peripheral blood from 166 patients with HCC and 157 healthy controls were detected by SYBR GREEN PCR method and the relationship between MDM2 polymorphism and susceptibility and biological behavior of HCC was analyzed by comparing the differences of genotypes in two populations. Results: There was no statistical significance between two groups in terms of MDM2 allele distribution in research population (P = 0.753. The risk of HCC onset in individuals with GG+ TG genotype was 1.698 times of those with TT genotype in case group (95%CI = 1.027 -2.808. MDM2 SNP was associated with HBV infection and the degree of tumor differentiation (P< 0.05. The incidence of alleles in experimental group (T, 0.49; G, 0.51 was very different from that in control group (T, 0.59; G, 0.41 (P = 0.015. The incidence of GG genotype in patients with HCC (22.29% was significantly higher than those without HCC (13.38%. Compared with TT genotype, G allele or GG genotype had more correlation with HCC onset. Conclusion: Compared with TT genotype, MDM2 promoter SNP309 G allele or GG genotype is more associated with HCC onset in Chinese population.

  3. Quantitative Single-letter Sequencing: a method for simultaneously monitoring numerous known allelic variants in single DNA samples

    Directory of Open Access Journals (Sweden)

    Duborjal Hervé

    2008-02-01

    Full Text Available Abstract Background Pathogens such as fungi, bacteria and especially viruses, are highly variable even within an individual host, intensifying the difficulty of distinguishing and accurately quantifying numerous allelic variants co-existing in a single nucleic acid sample. The majority of currently available techniques are based on real-time PCR or primer extension and often require multiplexing adjustments that impose a practical limitation of the number of alleles that can be monitored simultaneously at a single locus. Results Here, we describe a novel method that allows the simultaneous quantification of numerous allelic variants in a single reaction tube and without multiplexing. Quantitative Single-letter Sequencing (QSS begins with a single PCR amplification step using a pair of primers flanking the polymorphic region of interest. Next, PCR products are submitted to single-letter sequencing with a fluorescently-labelled primer located upstream of the polymorphic region. The resulting monochromatic electropherogram shows numerous specific diagnostic peaks, attributable to specific variants, signifying their presence/absence in the DNA sample. Moreover, peak fluorescence can be quantified and used to estimate the frequency of the corresponding variant in the DNA population. Using engineered allelic markers in the genome of Cauliflower mosaic virus, we reliably monitored six different viral genotypes in DNA extracted from infected plants. Evaluation of the intrinsic variance of this method, as applied to both artificial plasmid DNA mixes and viral genome populations, demonstrates that QSS is a robust and reliable method of detection and quantification for variants with a relative frequency of between 0.05 and 1. Conclusion This simple method is easily transferable to many other biological systems and questions, including those involving high throughput analysis, and can be performed in any laboratory since it does not require specialized

  4. Measurements of cold and hot water in ten dwellings; Maetning av kall- och varmvatten i tio hushaall

    Energy Technology Data Exchange (ETDEWEB)

    Wahlstroem, Aasa; Nordman, Roger; Pettersson, Ulrik (Swedish National Testing and Research Inst., Boraas (Sweden))

    2008-07-01

    Reducing tap water consumption has considerable potential for reducing overall environmental impact. It not only saves fresh water, but also gives significant savings of energy that would otherwise have been needed to heat hot water. However, in order to improve the energy efficiency of building services systems and to help occupants act more energy-efficiently, more knowledge is needed on how water is used in our homes. Today, we actually know very little about usage patterns from one tapping point to another, or the division between cold and hot water use, and this study aims to help provide appropriate information. The aim of this project is to increase the knowledge of how tap water is used in Swedish households. The main purpose is to gain knowledge of how to decrease the energy use and for that reason the description of the use of hot water is essential. Measurement has been made of hot and cold water use at each tapping point in ten dwellings: four apartments in apartment buildings, and six single-family buildings. The households were of the following categories; single, young couple, middle-aged couple and families with children. The number of households is too low to represent the water use at national level, but can still contribute with important knowledge of how we use water in our homes. The results show the following division of tap water use: - wash basin: 19% (11 % hot water and 8 % cold water); - kitchen sink 41% (23 % hot water and 18 % cold water); - shower/bathtub 40% (27 % hot water and 13 % cold water). About 61% of the total water quantity is hot water (note that cold water for toilet flushing and for laundry is not included in the total water use). The proportions between tapping points are very similar for the dwellings in the apartment buildings and single-family houses, and the use of water in the shower/bathtub is essentially the same as the use in the kitchens. In the single-family buildings the water use in laundry rooms was measured

  5. Scattering (stochastic) recoupling of a coupled ten-stripe AlGaAs-GaAs-InGaAs quantum-well heterostructure laser

    Science.gov (United States)

    Kellogg, D. A.; Holonyak, N.

    2001-04-01

    Data are presented on coupled ten-stripe AlGaAs-GaAs-InGaAs quantum well heterostructure (QWH) lasers recoupled stochastically at the cleaved end mirrors. Recoupling of neighboring elements of a ten-stripe laser is accomplished by the scattering (random feedback) afforded by applying ˜10-μm-diam Al powder or 0.3 μm α-Al2O3 polishing compound in microscopy immersion oil or in epoxy at the cleaved ends (mirrors). Data on QWH samples with the end mirrors coated with the scatterer (Al or Al2O3 powder in "liquid") exhibit spectral and far-field broadening, as well as increased laser threshold because of the reduced cavity Q. Single mode operation is possible with the conventional evanescent wave coupling of the ten-stripe QWH and is destroyed, even the laser operation itself, with the scattering recoupling (dephasing) at the end mirrors, which is reversible (removable). The narrow ten-stripe QWH laser with strong end-mirror scattering, a long amplifier with random feedback, indicates that a photopumped III-V or II-VI powder (a random "wall" cavity) has little or no merit.

  6. Calculation of calcium diffusion coefficient of cement hardenings using minute pore data

    International Nuclear Information System (INIS)

    Hitomi, Takashi; Takeda, Nobufumi; Iriya, Keishiro

    2009-01-01

    This report describes the calculations of the diffusion coefficient of the Ca ion of cement hardenings using minute pore data. The observed hardenings were ordinary Portland cement (OPC), low-heat Portland cement with fly ash (LPC+FA) and highly fly ash containing silica fume cement (HFSC). The samples were cured in the standard and artificially leached by accelerated test. Minute pore datas of the cement hardenings were acquired with image processing of internal structural information obtained from high resolution X-ray computed tomography observations. Upon analysis, several voxels are combined into one bigger voxel, the diffusion coefficient of the voxels were determined in proportion to the number of voxels which were included in. The results reveal that the change in the calcium diffusion coefficient of OPC due to leaching was large, but the LPC+FA and HFSC cements exhibited even greater changes than OPC. It is suggested that the diffusion coefficients are proportional to the Ca/Si ratio of the samples. (author)

  7. Cardiovascular Response Of Diabetic And Non-Diabetic Nigerian ...

    African Journals Online (AJOL)

    This study assessed the cardiovascular responses of diabetic and non-diabetic subjects to a single bout of bicycle ergometry. Ten male volunteer diabetics and ten male non-diabetic healthy subjects constituted the study and control groups respectively. The subjects exercised for ten minutes on a bicycle ergometer.

  8. One minute paper

    African Journals Online (AJOL)

    Arun Kumar Agnihotri

    One-Minute Paper: A thinking centered assessment tool. Ashakiran ... achievement of objectives and learning ability of the students, to analyze the questioning pattern of ... factual information, rote memory and critical thinking. The aim of every teacher while teaching ... question prompts another higher order cognitive skill ...

  9. Comparison of Single-Point and Continuous Sampling Methods for Estimating Residential Indoor Temperature and Humidity.

    Science.gov (United States)

    Johnston, James D; Magnusson, Brianna M; Eggett, Dennis; Collingwood, Scott C; Bernhardt, Scott A

    2015-01-01

    Residential temperature and humidity are associated with multiple health effects. Studies commonly use single-point measures to estimate indoor temperature and humidity exposures, but there is little evidence to support this sampling strategy. This study evaluated the relationship between single-point and continuous monitoring of air temperature, apparent temperature, relative humidity, and absolute humidity over four exposure intervals (5-min, 30-min, 24-hr, and 12-days) in 9 northern Utah homes, from March-June 2012. Three homes were sampled twice, for a total of 12 observation periods. Continuous data-logged sampling was conducted in homes for 2-3 wks, and simultaneous single-point measures (n = 114) were collected using handheld thermo-hygrometers. Time-centered single-point measures were moderately correlated with short-term (30-min) data logger mean air temperature (r = 0.76, β = 0.74), apparent temperature (r = 0.79, β = 0.79), relative humidity (r = 0.70, β = 0.63), and absolute humidity (r = 0.80, β = 0.80). Data logger 12-day means were also moderately correlated with single-point air temperature (r = 0.64, β = 0.43) and apparent temperature (r = 0.64, β = 0.44), but were weakly correlated with single-point relative humidity (r = 0.53, β = 0.35) and absolute humidity (r = 0.52, β = 0.39). Of the single-point RH measures, 59 (51.8%) deviated more than ±5%, 21 (18.4%) deviated more than ±10%, and 6 (5.3%) deviated more than ±15% from data logger 12-day means. Where continuous indoor monitoring is not feasible, single-point sampling strategies should include multiple measures collected at prescribed time points based on local conditions.

  10. Microwave-assisted headspace single-drop microextration of chlorobenzenes from water samples

    Energy Technology Data Exchange (ETDEWEB)

    Vidal, Lorena [Departamento de Quimica Analitica, Nutricion y Bromatologia, Universidad de Alicante, P.O. Box 99, E-03080 Alicante (Spain); Domini, Claudia E. [Departamento de Quimica Analitica, Nutricion y Bromatologia, Universidad de Alicante, P.O. Box 99, E-03080 Alicante (Spain); Grane, Nuria [Departamento de Quimica Analitica, Nutricion y Bromatologia, Universidad de Alicante, P.O. Box 99, E-03080 Alicante (Spain); Psillakis, Elefteria [Department of Environmental Engineering, Technical University of Crete, Polytechneioupolis, GR-73100 Chania, Crete (Greece); Canals, Antonio [Departamento de Quimica Analitica, Nutricion y Bromatologia, Universidad de Alicante, P.O. Box 99, E-03080 Alicante (Spain)]. E-mail: a.canals@ua.es

    2007-05-29

    A one-step and in-situ sample preparation method used for quantifying chlorobenzene compounds in water samples has been developed, coupling microwave and headspace single-drop microextraction (MW-HS-SDME). The chlorobenzenes in water samples were extracted directly onto an ionic liquid single-drop in headspace mode under the aid of microwave radiation. For optimization, a Plackett-Burman screening design was initially used, followed by a mixed-level factorial design. The factors considered were: drop volume, aqueous sample volume, stirring speed, ionic strength, extraction time, ionic liquid type, microwave power and length of the Y-shaped glass-tube. The optimum experimental conditions found from this statistical evaluation were: a 5 {mu}L microdrop of 1-hexyl-3-methylimidazolium hexafluorophosphate exposed for 20 min to the headspace of a 30 mL aqueous sample, irradiated by microwaves at 200 W and placed in a 50 mL spherical flask connected to a 25 cm Y-shaped glass-tube. Under the optimised experimental conditions, the response of a high performance liquid chromatographic system was found to be linear over the range studied and with correlation coefficients ranging between 0.9995 and 0.9999. The method showed a good level of repeatability, with relative standard deviations varying between 2.3 and 8.3% (n = 5). Detection limits were found in the low {mu}g L{sup -1} range varying between 0.016 and 0.039 {mu}g L{sup -1}. Overall, the performance of the proposed method demonstrated the favourable effect of microwave sample irradiation upon HS-SDME. Finally, recovery studies from different types of environmental water samples revealed that matrix had little effect upon extraction.

  11. Microwave-assisted headspace single-drop microextration of chlorobenzenes from water samples

    International Nuclear Information System (INIS)

    Vidal, Lorena; Domini, Claudia E.; Grane, Nuria; Psillakis, Elefteria; Canals, Antonio

    2007-01-01

    A one-step and in-situ sample preparation method used for quantifying chlorobenzene compounds in water samples has been developed, coupling microwave and headspace single-drop microextraction (MW-HS-SDME). The chlorobenzenes in water samples were extracted directly onto an ionic liquid single-drop in headspace mode under the aid of microwave radiation. For optimization, a Plackett-Burman screening design was initially used, followed by a mixed-level factorial design. The factors considered were: drop volume, aqueous sample volume, stirring speed, ionic strength, extraction time, ionic liquid type, microwave power and length of the Y-shaped glass-tube. The optimum experimental conditions found from this statistical evaluation were: a 5 μL microdrop of 1-hexyl-3-methylimidazolium hexafluorophosphate exposed for 20 min to the headspace of a 30 mL aqueous sample, irradiated by microwaves at 200 W and placed in a 50 mL spherical flask connected to a 25 cm Y-shaped glass-tube. Under the optimised experimental conditions, the response of a high performance liquid chromatographic system was found to be linear over the range studied and with correlation coefficients ranging between 0.9995 and 0.9999. The method showed a good level of repeatability, with relative standard deviations varying between 2.3 and 8.3% (n = 5). Detection limits were found in the low μg L -1 range varying between 0.016 and 0.039 μg L -1 . Overall, the performance of the proposed method demonstrated the favourable effect of microwave sample irradiation upon HS-SDME. Finally, recovery studies from different types of environmental water samples revealed that matrix had little effect upon extraction

  12. Successful replantation in ten-digit amputation.

    Science.gov (United States)

    Kantarci, Umit; Cepel, Selim; Buldu, Halil

    2010-01-01

    Amputations involving ten digits are very rare because of different lengths of the digits. A 34-year-old man working in a printing house presented one hour after guillotine amputation involving all ten digits. Surgery was initiated 80 minutes after admission and took seven hours. Under axillary anesthesia, the operation was performed by two teams each consisting of two microsurgeons and two assistants. Replantation was completed without the use of any skin graft or flap. Fingertip examination showed poor arterial circulation in the second, third, and fourth digits of the left hand after 24 hours of replantation and surgical exploration was performed, during which anastomosis of the ulnar digital artery of the second digit was re-established and a Y-shaped vein graft was placed at the level of the third web to restore revascularization of the third and fourth digits. However, these interventions did not prevent the development of necrosis in the distal segment of the fourth digit which resulted in dry gangrene that required amputation. After 38 months of replantation, radiographic examination showed complete union in all fingers without malunion or damage to the joint surface and about 8 degrees of medial angulation in the proximal phalanx of the fourth digit of the right hand. The patient did not have difficulty in performing daily activities and had a considerably good pinching. Losses of active range of motion of the metacarpophalangeal and interphalangeal joints were within the rage of 10 to 30 degrees in both hands. In the assessment of sensation, static and dynamic two-point discrimination test results were 6.1 mm and 4.0 mm, respectively.

  13. Test and evaluation of the Argonne BPAC10 Series air chamber calorimeter designed for 20 minute measurements

    International Nuclear Information System (INIS)

    Perry, R.B.; Fiarman, S.; Jung, E.A.; Cremers, T.

    1990-10-01

    This paper is the final report on DOE-OSS Task ANLE88002 ''Fast Air Chamber Calorimetry.'' The task objective was to design, construct, and test an isothermal air chamber calorimeter for plutonium assay of bulk samples that would meet the following requirements for sample power measurement: average sample measurement time less than 20 minutes. Measurement of samples with power output up to 10 W. Precision of better than 1% RSD for sample power greater than 1 W. Precision better than 0.010 watt SD, for sample power less than 1 W. This report gives a description of the calorimeter hardware and software and discusses the test results. The instrument operating procedure, included as an appendix, gives examples of typical input/output and explains the menu driven software. Sample measurement time of less than 20 minutes was attained by pre-equilibration of the samples in low cost precision preheaters and by prediction of equilibrium measurements. Tests at the TA55 Plutonium Facility at Los Alamos National Laboratory, on typical samples, indicates that the instrument meets all the measurement requirements

  14. Effect of Sample Storage Temperature and Time Delay on Blood Gases, Bicarbonate and pH in Human Arterial Blood Samples.

    Science.gov (United States)

    Mohammadhoseini, Elham; Safavi, Enayat; Seifi, Sepideh; Seifirad, Soroush; Firoozbakhsh, Shahram; Peiman, Soheil

    2015-03-01

    Results of arterial blood gas analysis can be biased by pre-analytical factors, such as time interval before analysis, temperature during storage and syringe type. To investigate the effects of samples storage temperature and time delay on blood gases, bicarbonate and PH results in human arterial blood samples. 2.5 mL arterial blood samples were drawn from 45 patients via an indwelling Intraarterial catheter. Each sample was divided into five equal samples and stored in multipurpose tuberculin plastic syringes. Blood gas analysis was performed on one of five samples as soon as possible. Four other samples were divided into two groups stored at 22°C and 0°C. Blood gas analyses were repeated at 30 and 60 minutes after sampling. PaO2 of the samples stored at 0°C was increased significantly after 60 minutes (P = 0.007). The PaCO2 of the samples kept for 30 and 60 minutes at 22°C was significantly higher than primary result (P = 0.04, P samples stored at 22°C, pH decreased significantly after 30 and 60 minutes (P = 0.017, P = 0.001). There were no significant differences in other results of samples stored at 0°C or 22°C after 30 or 60 minutes. In samples stored in plastic syringes, overestimation of PaO2 levels should be noted if samples cooled before analysis. In samples stored in plastic syringes, it is not necessary to store samples in iced water when analysis delayed up to one hour.

  15. Science-based response planning guidance for the first 100 minutes of the response to a radiological dispersal device

    International Nuclear Information System (INIS)

    Musolino, S.V.; Harper, F.T.

    2016-01-01

    The first 100 minutes of a response to a radiological dispersal device are critical as this period will set the stage for how the overall response will be executed. First responders will be tasked with multiple activities such as confirming a radiological release, conducting lifesaving rescue operations, issuing protective actions, and beginning characterization of the scene. These activities need to take place as soon as the responders arrive on the scene (the first few minutes). The effectiveness of these early activities will define how well or how poorly the response will be in the emergency phase. The document which is under development provides guidance that can be used for planning an effective response to an RDD that will result in protection of the responders and the members of the public. The information is based on research and results of extensive experiments conducted by the Department of Energy National Laboratories. This guidance provides a realistic estimate of the possible consequences of an RDD detonation and delineates five missions and ten tactics that should be executed by the first responders and local response agencies in the first 100 minutes of a response. The guidance includes recommendations on how to execute the strategy, equipment requirements including personal protective equipment and public messaging

  16. Single-Dose Lignocaine-Based Blood Cardioplegia in Single Valve Replacement Patients

    Directory of Open Access Journals (Sweden)

    Jaydip Ramani

    Full Text Available Abstract OBJECTIVE: Myocardial protection is the most important in cardiac surgery. We compared our modified single-dose long-acting lignocaine-based blood cardioplegia with short-acting St Thomas 1 blood cardioplegia in patients undergoing single valve replacement. METHODS: A total of 110 patients who underwent single (aortic or mitral valve replacement surgery were enrolled. Patients were divided in two groups based on the cardioplegia solution used. In group 1 (56 patients, long-acting lignocaine based-blood cardioplegia solution was administered as a single dose while in group 2 (54 patients, standard St Thomas IB (short-acting blood-based cardioplegia solution was administered and repeated every 20 minutes. All the patients were compared for preoperative baseline parameters, intraoperative and all the postoperative parameters. RESULTS: We did not find any statistically significant difference in preoperative baseline parameters. Cardiopulmonary bypass time were 73.8±16.5 and 76.4±16.9 minutes (P=0.43 and cross clamp time were 58.9±10.3 and 66.3±11.2 minutes (P=0.23 in group 1 and group 2, respectively. Mean of maximum inotrope score was 6.3±2.52 and 6.1±2.13 (P=0.65 in group 1 and group 2, respectively. We also did not find any statistically significant difference in creatine-phosphokinase-MB (CPK-MB, Troponin-I levels, lactate level and cardiac functions postoperatively. CONCLUSION: This study proves the safety and efficacy of long-acting lignocaine-based single-dose blood cardioplegia compared to the standard short-acting multi-dose blood cardioplegia in patients requiring the single valve replacement. Further studies need to be undertaken to establish this non-inferiority in situations of complex cardiac procedures especially in compromised patients.

  17. Pumping time required to obtain tube well water samples with aquifer characteristic radon concentrations

    International Nuclear Information System (INIS)

    Ricardo, Carla Pereira; Oliveira, Arno Heeren de

    2011-01-01

    Radon is an inert noble gas, which comes from the natural radioactive decay of uranium and thorium in soil, rock and water. Radon isotopes emanated from radium-bearing grains of a rock or soil are released into the pore space. Radon that reaches the pore space is partitioned between the gaseous and aqueous phases. Thus, the groundwater presents a radon signature from the rock that is characteristic of the aquifer. The characteristic radon concentration of an aquifer, which is mainly related to the emanation, is also influenced by the degree of subsurface degassing, especially in the vicinity of a tube well, where the radon concentration is strongly reduced. Looking for the required pumping time to take a tube well water sample that presents the characteristic radon concentration of the aquifer, an experiment was conducted in an 80 m deep tube well. In this experiment, after twenty-four hours without extraction, water samples were collected periodically, about ten minutes intervals, during two hours of pumping time. The radon concentrations of the samples were determined by using the RAD7 Electronic Radon Detector from Durridge Company, a solid state alpha spectrometric detector. It was realized that the necessary time to reach the maximum radon concentration, that means the characteristic radon concentration of the aquifer, is about sixty minutes. (author)

  18. The quantitative regional cerebral blood flow measurement with autoradiography method using 123I-IMP SPECT. Evaluation of arterialized venous blood sampling as a substitute for arterial blood sampling

    International Nuclear Information System (INIS)

    Ohnishi, Takashi; Yano, Takao; Nakano, Shinichi; Jinnouchi, Seishi; Nagamachi, Shigeki; Flores, L. II; Nakahara, Hiroshi; Watanabe, Katsushi.

    1996-01-01

    The purpose of this study is validation of calibrating a standard input function in autoradiography (ARG) method by one point venous blood sampling as a substitute for that by one point arterial blood sampling. Ten and 20 minutes after intravenous constant infusion of 123 I-IMP, arterialized venous blood sampling from a dorsal vein were performed on 15 patients having ischemic cerebrovascular disease. And arterial blood sampling from radial artery was performed 10 min after 123 I-IMP infusion. The mean difference rates of integrated input function between calibrated standard input function by arterial blood sampling at 10 min and that by venous blood sampling were 4.1±3% and 9.3±5.4% at 10 and 20 min after 123 I-IMP infusion, respectively. The ratio of venous blood radioactivity to arterial blood radioactivity at 10 min after 123 I-IMP infusion was 0.96±0.02. There was an excellent correlation between ARG method CBF values obtained by arterial blood sampling at 10 min and those obtained by arterialized venous blood sampling at 10 min. In conclusion, a substitution by arterialized venous blood sampling from dorsal hand vein for artery can be possible. The optimized time for arterialized venous blood sampling was 10 min after 123 I-IMP infusion. (author)

  19. Different mechanisms for the short-term effects of real versus sham transcutaneous electrical nerve stimulation (TENS) in patients with chronic pain: a pilot study.

    Science.gov (United States)

    Oosterhof, Jan; Wilder-Smith, Oliver H; Oostendorp, Rob A; Crul, Ben J

    2012-01-01

    Transcutaneous electrical nerve stimulation (TENS) has existed since the early 1970s. However, randomized placebo controlled studies show inconclusive results in the treatment of chronic pain. These results could be explained by assuming that TENS elicits a placebo response. However, in animal research TENS has been found to decrease hyperalgesia, which contradicts this assumption. The aim of this study is to use quantitative sensory testing to explore changes in pain processing during sham versus real TENS in patients with chronic pain. Patients with chronic pain (N = 20) were randomly allocated to real TENS or sham TENS application. Electrical pain thresholds (EPTs) were determined inside and outside the segment stimulated, before and after the first 20 minutes of the intervention, and after a period of 10 days of daily real/sham TENS application. Pain relief did not differ significantly for real versus sham TENS. However, by comparing time courses of EPTs, it was found that EPT values outside the segment of stimulation increased for sham TENS, whereas for real TENS these values decreased. There were, however, no differences for EPT measurements inside the segment stimulated. These results illustrate the importance of including mechanism-reflecting parameters in addition to symptoms when conducting pain research.

  20. Clinical experience with TENS and TENS combined with nitrous oxide-oxygen. Report of 371 patients.

    OpenAIRE

    Quarnstrom, F. C.; Milgrom, P.

    1989-01-01

    Transcutaneous electrical nerve stimulation (TENS) alone or TENS combined with nitrous oxide-oxygen (N2O) was administered for restorative dentistry without local anesthesia to 371 adult patients. A total of 55% of TENS alone and 84% of TENS/N2O visits were rated successful. A total of 53% of TENS alone and 82% of TENS/N2O patients reported slight or no pain. In multivariable analyses, pain reports were related to the anesthesia technique and patient fear and unrelated to sex, race, age, toot...

  1. Norepinephrine remains increased in the six-minute walking test after heart transplantation

    Directory of Open Access Journals (Sweden)

    Guilherme Veiga Guimarães

    2010-01-01

    Full Text Available OBJECTIVE: We sought to evaluate the neurohormonal activity in heart transplant recipients and compare it with that in heart failure patients and healthy subjects during rest and just after a 6-minute walking test. INTRODUCTION: Despite the improvements in quality of life and survival provided by heart transplantation, the neurohormonal profile is poorly described. METHODS: Twenty heart transplantation (18 men, 49±11 years and 8.5±3.3 years after transplantation, 11 heart failure (8 men, 43±10 years, and 7 healthy subjects (5 men 39±8 years were included in this study. Blood samples were collected immediately before and during the last minute of the exercise. RESULTS: During rest, patients' norepinephrine plasma level (659±225 pg/mL was higher in heart transplant recipients (463±167 pg/mL and heathy subjects (512±132, p<0.05. Heart transplant recipient's norepinephrine plasma level was not different than that of healthy subjects. Just after the 6-minute walking test, the heart transplant recipient's norepinephrine plasma level (1248±692 pg/mL was not different from that of heart failure patients (1174±653 pg/mL. Both these groups had a higher level than healthy subjects had (545±95 pg/mL, p<0.05. CONCLUSION: Neurohormonal activity remains increased after the 6-minute walking test after heart transplantation.

  2. Transcutaneous Electrical Nerve Stimulation (TENS) reduces pain, fatigue, and hyperalgesia while restoring central inhibition in primary fibromyalgia

    OpenAIRE

    Dailey, Dana L; Rakel, Barbara A; Vance, Carol GT; Liebano, Richard E; Anand, Amrit S; Bush, Heather M; Lee, Kyoung S; Lee, Jennifer E; Sluka, Kathleen A

    2013-01-01

    Because TENS works by reducing central excitability and activating central inhibition pathways, we tested the hypothesis that TENS would reduce pain and fatigue and improve function and hyperalgesia in people with fibromyalgia who have enhanced central excitability and reduced inhibition. The current study used a double-blinded randomized, placebo controlled cross-over design to test effects of a single treatment of TENS in people with fibromyalgia. Three treatments were assessed in random or...

  3. SHORT TERM EFFECT OF ACUPUNCTURE-TENS ON LUNG FUNCTIONS AND DYSPNEA FOR SUBJECTS WITH MODERATE COPD

    Directory of Open Access Journals (Sweden)

    Vinod Babu. K

    2015-10-01

    Full Text Available Background: Acupuncture TENS is used to improve pain instead of invasive acupuncture. Acupuncture shown to improve dyspnoea and lung functions in COPD (Chronic Obstructive Pulmonary Disease patients. The purpose of the study is to determine Short term effectiveness of Acupuncture-TENS in reducing dyspnea and improving lung functions for subjects with moderate COPD. Method: An experimental study design, selected 30 geriatric subjects with COPD randomized 15 subjects into each Study and Control group. Study group received Acu-TENS for 45 minutes for total 5 sessions, while control group received placebo TENS. Outcome measurements such as breathlessness using Modified Borg Scale (MBS, Lung functions using Pulmonary Function Test (PFT was measured before and after intervention. Results: Analysis from pre-intervention to post-intervention within study group found that there is statistically significant change in means of MBS, FEV1, FEV1/FVC ratio and within control group there is a statistically significant change in means of MBS, but there is no statistically significant change in means of FEV1, FVC and FEV1/FVC ratio. When post-intervention means were compared between the groups there is no statistically significant difference in means of MBS and FEV1, FVC and FEV1/FVC ratio. Conclusion: It is concluded that one week of Acu-TENS on EXL1 point found no significant effect on improving dyspnea and lung functions in subjects with moderate COPD in geriatric populations.

  4. Communication: Multiple atomistic force fields in a single enhanced sampling simulation

    Energy Technology Data Exchange (ETDEWEB)

    Hoang Viet, Man [Department of Physics, North Carolina State University, Raleigh, North Carolina 27695-8202 (United States); Derreumaux, Philippe, E-mail: philippe.derreumaux@ibpc.fr [Laboratoire de Biochimie Théorique, UPR 9080, CNRS, Université Denis Diderot, Sorbonne Paris Cité IBPC, 13 rue Pierre et Marie Curie, 75005 Paris (France); Institut Universitaire de France, 103 Bvd Saint-Germain, 75005 Paris (France); Nguyen, Phuong H., E-mail: phuong.nguyen@ibpc.fr [Laboratoire de Biochimie Théorique, UPR 9080, CNRS, Université Denis Diderot, Sorbonne Paris Cité IBPC, 13 rue Pierre et Marie Curie, 75005 Paris (France)

    2015-07-14

    The main concerns of biomolecular dynamics simulations are the convergence of the conformational sampling and the dependence of the results on the force fields. While the first issue can be addressed by employing enhanced sampling techniques such as simulated tempering or replica exchange molecular dynamics, repeating these simulations with different force fields is very time consuming. Here, we propose an automatic method that includes different force fields into a single advanced sampling simulation. Conformational sampling using three all-atom force fields is enhanced by simulated tempering and by formulating the weight parameters of the simulated tempering method in terms of the energy fluctuations, the system is able to perform random walk in both temperature and force field spaces. The method is first demonstrated on a 1D system and then validated by the folding of the 10-residue chignolin peptide in explicit water.

  5. Monitoring of Pb exposure in waterfowl ten years after a mine spill through the use of noninvasive sampling.

    Directory of Open Access Journals (Sweden)

    Monica Martinez-Haro

    Full Text Available Lead exposure in waterfowl was studied using noninvasive fecal sampling in the Guadalquivir Marshes in Spain, an area affected by the 1998 Aznalcóllar mine disaster. Feces of greylag geese (Anser anser, n = 191 and purple gallinule (Porphyrio porphyrio, n = 91 were collected from three different impacted sites (Entremuros, Caracoles and Cerro de los Ánsares during the winters of 2004 to 2008. Lead and aluminium (an indicator of sediment ingestion and Pb isotope signatures (to discriminate between sources of Pb exposure were analyzed in freeze-dried, acid digested samples. The concentrations of fecal porphyrins and biliverdin were determined as noninvasive biomarkers to study Pb exposure effects. Results showed a decrease in Pb exposure over time in wintering greylag geese. In contrast, for purple gallinule resident in the Entremuros a clear trend was not evident. For both species, sediment ingestion appeared to be the main source of exposure to Pb. In the Entremuros, some samples from purple gallinule were detected with higher Pb levels than expected for simple soil ingestion, and these had Pb isotopic profiles compatible with mining sludge or Pb shot. Whilst fecal Pb isotopic profiles were effective in differentiating between samples from sites with different levels and sources of pollution, the combined use of element ratios (such as Pb/Al and other non-traditional stable isotope signatures may also prove worthwhile. Overall, the fecal Pb levels detected were below those described in feces for waterfowl from other uncontaminated areas(<10 µg/g d.w.. Despite this, for both species fecal Pb levels were positively correlated with porphyrin excretion, and for purple gallinule, with the coproporphyrin III/I ratio, suggesting some subtle effects on heme synthesis in birds. Ten years after the mine spill, Pb contamination in birds by this pollution source was still detectable and subtlethal effects may persist.

  6. Ten Indicators of Vitality in Smaller Academic Libraries

    Science.gov (United States)

    Pappas, David

    2009-01-01

    This paper provides a means of quickly ascertaining the relative health of smaller academic libraries by presenting a top ten list of vitality indicators. The list is based on an observational convenience sampling of thirty smaller academic libraries across the United States. The indicators making the list were those which appeared most often in…

  7. Single-incision laparoscopic distal gastrectomy for early gastric cancer through a homemade single port access device.

    Science.gov (United States)

    Jiang, Zhi-Wei; Zhang, Shu; Wang, Gang; Zhao, Kun; Liu, Jiang; Ning, Li; Li, Jieshou

    2015-01-01

    We presented a series of single-incision laparoscopic distal gastrectomies for early gastric cancer patients through a type of homemade single port access device and some other conventional laparoscopic instruments. A single-incision laparoscopic distal gastrectomy with D1 + α lymph node dissection was performed on a 46 years old male patient who had an early gastric cancer. This single port access device has facilitated the conventional laparoscopic instruments to accomplish the surgery and we made in only 6 minutes. Total operating time for this surgery was 240 minutes. During the operation, there were about 100 milliliters of blood loss, and 17 lymph-nodes were retrieved. This homemade single port access device shows its superiority in economy and convenience for complex single-incision surgeries. Single-incision laparoscopic distal gastrectomy for early gastric cancer can be conducted by experienced laparoscopic surgeons. Fully take advantage of both SILS and fast track surgery plan can bring to successful surgeries with minimal postoperative pain, quicker mobilization, early recovery of intestinal function, and better cosmesis effect for the patients.

  8. Creation of oxygen-enriched layers at the surface of GaAs single crystal

    International Nuclear Information System (INIS)

    Kulik, M.; Maczka, D.; Kobzev, A.P.

    1999-01-01

    The optical properties and the element depth profiles at the (100) plane high resistant and noncomposite GaAs single crystals implanted with In ions were investigated. The results have been compared with those obtained for virgin samples. The optic properties for all of the samples (implanted and not implanted, annealed and not annealed) have been measured using the ellipsometric method. The element depth profiles for the same samples have been obtained by the RBS and NRA techniques. It has been shown that the post-implantation annealing at a temperature more than 600 deg C leads to a ten time increase in contents of oxygen atoms in the implanted layer with respect to the not annealed sample. The thickness of the transparence layer at the surface of GaAs single crystal increases also after implantation with In ions and subsequent annealing

  9. Comparison of semiautomated bird song recognition with manual detection of recorded bird song samples

    Directory of Open Access Journals (Sweden)

    Lisa A. Venier

    2017-12-01

    Full Text Available Automated recording units are increasingly being used to sample wildlife populations. These devices can produce large amounts of data that are difficult to process manually. However, the information in the recordings can be summarized with semiautomated sound recognition software. Our objective was to assess the utility of the semiautomated bird song recognizers to produce data useful for conservation and sustainable forest management applications. We compared detection data generated from expert-interpreted recordings of bird songs collected with automated recording units and data derived from a semiautomated recognition process. We recorded bird songs at 109 sites in boreal forest in 2013 and 2014 using automated recording units. We developed bird-song recognizers for 10 species using Song Scope software (Wildlife Acoustics and each recognizer was used to scan a set of recordings that was also interpreted manually by an expert in birdsong identification. We used occupancy models to estimate the detection probability associated with each method. Based on these detection probability estimates we produced cumulative detection probability curves. In a second analysis we estimated detection probability of bird song recognizers using multiple 10-minute recordings for a single station and visit (35-63, 10-minute recordings in each of four one-week periods. Results show that the detection probability of most species from single 10-min recordings is substantially higher using expert-interpreted bird song recordings than using the song recognizer software. However, our results also indicate that detection probabilities for song recognizers can be significantly improved by using more than a single 10-minute recording, which can be easily done with little additional cost with the automate procedure. Based on these results we suggest that automated recording units and song recognizer software can be valuable tools to estimate detection probability and

  10. Ergonomic evaluation of ten single-channel pipettes.

    Science.gov (United States)

    Lichty, Monica G; Janowitz, Ira L; Rempel, David M

    2011-01-01

    Repetitive pipetting is a task that is associated with work-related musculoskeletal disorders of the hand and arm. The purpose of this study was to evaluate the usability and ergonomic performance of commercially available pipettes as determined by user ratings and objective measurements. Participants were laboratory technicians and scientists at the Lawrence Berkeley National Laboratory with experience performing pipetting tasks. Twenty-one experienced pipette users completed a standardized pipetting task with 5 manual and 5 electronic pipettes. After using each pipette, the user rated it for attributes of comfort and usability. Although no single pipette was rated significantly better than all of the others for every attribute tested, some significant differences were found between pipettes. The Rainin Pipet-Lite received the highest overall quality score among manual pipettes, while the Thermo Scientific Finnpipette Novus was the top-ranked electronic pipette. Features correlated with greater hand and arm comfort were lower tip ejection force, lower blowout force, and pipette balance in the hand. The findings, when considered with participant comments, provide insights into desirable pipette features and emphasize the value of user testing and the importance of the interactions between task, workplace layout, and pipette design. © 2011 - IOS Press and the authors. All rights reserved

  11. AN ANALYSIS OF TEN YEARS OF THE FOUR GRAND SLAM MEN'S SINGLES DATA FOR LACK OF INDEPENDENCE OF SET OUTCOMES

    Directory of Open Access Journals (Sweden)

    Denny Meyer

    2006-12-01

    Full Text Available The objective of this paper is to use data from the highest level in men's tennis to assess whether there is any evidence to reject the hypothesis that the two players in a match have a constant probability of winning each set in the match. The data consists of all 4883 matches of grand slam men's singles over a 10 year period from 1995 to 2004. Each match is categorised by its sequence of win (W or loss (L (in set 1, set 2, set 3,... to the eventual winner. Thus, there are several categories of matches from WWW to LLWWW. The methodology involves fitting several probabilistic models to the frequencies of the above ten categories. One four-set category is observed to occur significantly more often than the other two. Correspondingly, a couple of the five-set categories occur more frequently than the others. This pattern is consistent when the data is split into two five-year subsets. The data provides significant statistical evidence that the probability of winning a set within a match varies from set to set. The data supports the conclusion that, at the highest level of men's singles tennis, the better player (not necessarily the winner lifts his play in certain situations at least some of the time

  12. HIPs at Ten

    Science.gov (United States)

    Kuh, George; O'Donnell, Ken; Schneider, Carol Geary

    2017-01-01

    2017 is the anniversary of the introduction of what are now commonly known as high-impact practices (HIPs). Many of the specific activities pursued under the HIPs acronym have been around in some form for decades, such as study abroad, internships, and student-faculty research. It was about ten years ago that, after conferring HIPs at Ten with…

  13. Massively Parallel Single-Molecule Manipulation Using Centrifugal Force

    Science.gov (United States)

    Wong, Wesley; Halvorsen, Ken

    2011-03-01

    Precise manipulation of single molecules has led to remarkable insights in physics, chemistry, biology, and medicine. However, two issues that have impeded the widespread adoption of these techniques are equipment cost and the laborious nature of making measurements one molecule at a time. To meet these challenges, we have developed an approach that enables massively parallel single- molecule force measurements using centrifugal force. This approach is realized in the centrifuge force microscope, an instrument in which objects in an orbiting sample are subjected to a calibration-free, macroscopically uniform force- field while their micro-to-nanoscopic motions are observed. We demonstrate high- throughput single-molecule force spectroscopy with this technique by performing thousands of rupture experiments in parallel, characterizing force-dependent unbinding kinetics of an antibody-antigen pair in minutes rather than days. Currently, we are taking steps to integrate high-resolution detection, fluorescence, temperature control and a greater dynamic range in force. With significant benefits in efficiency, cost, simplicity, and versatility, single-molecule centrifugation has the potential to expand single-molecule experimentation to a wider range of researchers and experimental systems.

  14. Optimal sampling strategies to assess inulin clearance in children by the inulin single-injection method

    NARCIS (Netherlands)

    van Rossum, Lyonne K.; Mathot, Ron A. A.; Cransberg, Karlien; Vulto, Arnold G.

    2003-01-01

    Glomerular filtration rate in patients can be determined by estimating the plasma clearance of inulin with the single-injection method. In this method, a single bolus injection of inulin is administered and several blood samples are collected. For practical and convenient application of this method

  15. Ten design lessons from the literature on child development and children’s use of technology

    CSIR Research Space (South Africa)

    Gelderblom, H

    2009-06-01

    Full Text Available sampling, data collection and data analysis [15]. We used multiple case sampling [28] to establish a trustworthy profile of five to eight year old children and reputational case selection [28] to choose the relevant theories of development, research... here will confirm. For this paper we selected, from the complete framework, ten themes to focus on. We present the guidelines associated with these themes as ten ‘lessons’ grounded in respected theoretical or empirical research results...

  16. Photospheric Origin of Three-minute Oscillations in a Sunspot

    Energy Technology Data Exchange (ETDEWEB)

    Chae, Jongchul; Lee, Jeongwoo; Cho, Kyuhyoun; Song, Donguk [Astronomy Program, Department of Physics and Astronomy, Seoul National University, 1 Gwanak-ro, Gwanak-gu, Seoul 08826 (Korea, Republic of); Cho, Kyungsuk; Yurchyshyn, Vasyl [Korea Astronomy and Space Science Institute, 776 Daedeokdae-ro, Yuseong-gu, Daejeon 34055 (Korea, Republic of)

    2017-02-10

    The origin of the three-minute oscillations of intensity and velocity observed in the chromosphere of sunspot umbrae is still unclear. We investigated the spatio-spectral properties of the 3 minute oscillations of velocity in the photosphere of a sunspot umbra as well as those in the low chromosphere using the spectral data of the Ni i λ 5436, Fe i λ 5435, and Na i D{sub 2} λ 5890 lines taken by the Fast Imaging Solar Spectrograph of the 1.6 m New Solar Telescope at the Big Bear Solar Observatory. As a result, we found a local enhancement of the 3 minute oscillation power in the vicinities of a light bridge (LB) and numerous umbral dots (UDs) in the photosphere. These 3 minute oscillations occurred independently of the 5 minute oscillations. Through wavelet analysis, we determined the amplitudes and phases of the 3 minute oscillations at the formation heights of the spectral lines, and they were found to be consistent with the upwardly propagating slow magnetoacoustic waves in the photosphere with energy flux large enough to explain the chromospheric oscillations. Our results suggest that the 3 minute chromospheric oscillations in this sunspot may have been generated by magnetoconvection occurring in the LB and UDs.

  17. Changes in users' Web search performance after ten years ...

    African Journals Online (AJOL)

    The changes in users' Web search performance using search engines over ten years was investigated in this study. Matched data obtained from samples in 2000 and 2010 were used for the comparative analysis. The patterns of Web search engine use suggested a dominance in using a particular search engine. Statistical ...

  18. Antimicrobial activity of Verbascum macrurum Ten. (Scrophulariaceae).

    Science.gov (United States)

    Guarino, C

    2002-01-01

    The Author presents the results regarding the antibacterial action of extracts of Verbascum macrurum Ten.. The leaves of this species, gathered on the slopes of Mt. Matese, were ground and four extracts were made as follows: with dicholoromethane, ethonol and water (70:30 v/v), water and methanol. The antibacterial activity of each of the samples was tested and it is demonstrated that the extract with the ethanol/water was the most activity one.

  19. Stevens Johnson syndrome, toxic epidermal necrolysis and SJS-TEN overlap: A retrospective study of causative drugs and clinical outcome

    Directory of Open Access Journals (Sweden)

    Sharma Vinod

    2008-01-01

    Full Text Available Background and Aims: Stevens Johnson syndrome (SJS, toxic epidermal necrolysis (TEN and SJS-TEN overlap are serious adverse cutaneous drug reactions. Drugs are often implicated in these reactions. Methods: A retrospective analysis of inpatients′ data with these dermatological diagnoses were carried out for three years, to study the causative drugs, clinical outcome, and mortality in these conditions. Results: Thirty patients (15 TEN, nine SJS-TEN overlap, and six SJS were admitted. In 21 cases, multiple drugs were implicated whereas single drugs were responsible in nine. Anticonvulsants (35.08% were the most commonly implicated drugs followed by antibiotics (33.33% and NSAIDS (24.56%. Twenty-five patients recovered whereas five died (four TEN, one SJS-TEN overlap. Conclusion: Anticonvulsants, antibiotics and NSAIDs were the most frequently implicated drugs. TEN causes higher mortality than both SJS and SJS-TEN overlap.

  20. Effect of dislocation pile-up on size-dependent yield strength in finite single-crystal micro-samples

    Energy Technology Data Exchange (ETDEWEB)

    Pan, Bo; Shibutani, Yoji, E-mail: sibutani@mech.eng.osaka-u.ac.jp [Department of Mechanical Engineering, Osaka University, Suita 565-0871 (Japan); Zhang, Xu [State Key Laboratory for Strength and Vibration of Mechanical Structures, School of Aerospace, Xi' an Jiaotong University, Xi' an 710049 (China); School of Mechanics and Engineering Science, Zhengzhou University, Zhengzhou 450001 (China); Shang, Fulin [State Key Laboratory for Strength and Vibration of Mechanical Structures, School of Aerospace, Xi' an Jiaotong University, Xi' an 710049 (China)

    2015-07-07

    Recent research has explained that the steeply increasing yield strength in metals depends on decreasing sample size. In this work, we derive a statistical physical model of the yield strength of finite single-crystal micro-pillars that depends on single-ended dislocation pile-up inside the micro-pillars. We show that this size effect can be explained almost completely by considering the stochastic lengths of the dislocation source and the dislocation pile-up length in the single-crystal micro-pillars. The Hall–Petch-type relation holds even in a microscale single-crystal, which is characterized by its dislocation source lengths. Our quantitative conclusions suggest that the number of dislocation sources and pile-ups are significant factors for the size effect. They also indicate that starvation of dislocation sources is another reason for the size effect. Moreover, we investigated the explicit relationship between the stacking fault energy and the dislocation “pile-up” effect inside the sample: materials with low stacking fault energy exhibit an obvious dislocation pile-up effect. Our proposed physical model predicts a sample strength that agrees well with experimental data, and our model can give a more precise prediction than the current single arm source model, especially for materials with low stacking fault energy.

  1. SERE: single-parameter quality control and sample comparison for RNA-Seq.

    Science.gov (United States)

    Schulze, Stefan K; Kanwar, Rahul; Gölzenleuchter, Meike; Therneau, Terry M; Beutler, Andreas S

    2012-10-03

    Assessing the reliability of experimental replicates (or global alterations corresponding to different experimental conditions) is a critical step in analyzing RNA-Seq data. Pearson's correlation coefficient r has been widely used in the RNA-Seq field even though its statistical characteristics may be poorly suited to the task. Here we present a single-parameter test procedure for count data, the Simple Error Ratio Estimate (SERE), that can determine whether two RNA-Seq libraries are faithful replicates or globally different. Benchmarking shows that the interpretation of SERE is unambiguous regardless of the total read count or the range of expression differences among bins (exons or genes), a score of 1 indicating faithful replication (i.e., samples are affected only by Poisson variation of individual counts), a score of 0 indicating data duplication, and scores >1 corresponding to true global differences between RNA-Seq libraries. On the contrary the interpretation of Pearson's r is generally ambiguous and highly dependent on sequencing depth and the range of expression levels inherent to the sample (difference between lowest and highest bin count). Cohen's simple Kappa results are also ambiguous and are highly dependent on the choice of bins. For quantifying global sample differences SERE performs similarly to a measure based on the negative binomial distribution yet is simpler to compute. SERE can therefore serve as a straightforward and reliable statistical procedure for the global assessment of pairs or large groups of RNA-Seq datasets by a single statistical parameter.

  2. 5-minute Gridded Global Relief Data (ETOPO5)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Earth topography five minute grid (ETOPO5) is a gridded data base of worldwide elevations derived from several sources at a resolution of 5 minutes of latitude and...

  3. Transcutaneous electric nerve stimulation (TENS) for cancer pain in adults.

    Science.gov (United States)

    Hurlow, Adam; Bennett, Michael I; Robb, Karen A; Johnson, Mark I; Simpson, Karen H; Oxberry, Stephen G

    2012-03-14

    Cancer-related pain is complex and multi-dimensional but the mainstay of cancer pain management has predominantly used a biomedical approach. There is a need for non-pharmacological and innovative approaches. Transcutaneous Electric Nerve Stimulation (TENS) may have a role in pain management but the effectiveness of TENS is currently unknown. This is an update of the original review published in Issue 3, 2008. The aim of this systematic review was to determine the effectiveness of TENS for cancer-related pain in adults. The initial review searched The Cochrane Library, MEDLINE, EMBASE, CINAHL, PsychINFO, AMED and PEDRO databases in April 2008. We performed an updated search of CENTRAL, MEDLINE, EMBASE, CINAHL and PEDRO databases in November 2011. We included only randomised controlled trials (RCTS) investigating the use of TENS for the management of cancer-related pain in adults. The search strategy identified a further two studies for possible inclusion. One of the review authors screened each abstract using a study eligibility tool. Where eligibility could not be determined, a second author assessed the full paper. One author used a standardised data extraction sheet to collect information on the studies and independently assess the quality of the studies using the validated five-point Oxford Quality Scale. The small sample sizes and differences in patient study populations of the three included studies (two from the original review and a third included in this update) prevented meta-analysis. For the original review the search strategy identified 37 possible published studies; we divided these between two pairs of review authors who decided on study selection; all four review authors discussed and agreed final scores. Only one additional RCT met the eligibility criteria (24 participants) for this updated review. Although this was a feasibility study, not designed to investigate intervention effect, it suggested that TENS may improve bone pain on movement in a

  4. Six-minute walking distance and decrease in oxygen saturation during the six-minute walk test in pediatric pulmonary arterial hypertension

    NARCIS (Netherlands)

    Douwes, Johannes M.; Hegeman, Anneke K.; van der Krieke-van der Horst, Merel; Roofthooft, Marcus T. R.; Hillege, Hans L.; Berger, Rolf M. F.

    2016-01-01

    Objective: To investigate the prognostic value of the 6-minute walking distance (6-MWD), transcutaneous saturation (tcSO2) and heart rate (HR) obtained during the 6-minute walk test (6-MWT) in pediatric pulmonary arterial hypertension (PAH). Methods: This was an observational study with forty-seven

  5. Estimating fluvial wood discharge from timelapse photography with varying sampling intervals

    Science.gov (United States)

    Anderson, N. K.

    2013-12-01

    There is recent focus on calculating wood budgets for streams and rivers to help inform management decisions, ecological studies and carbon/nutrient cycling models. Most work has measured in situ wood in temporary storage along stream banks or estimated wood inputs from banks. Little effort has been employed monitoring and quantifying wood in transport during high flows. This paper outlines a procedure for estimating total seasonal wood loads using non-continuous coarse interval sampling and examines differences in estimation between sampling at 1, 5, 10 and 15 minutes. Analysis is performed on wood transport for the Slave River in Northwest Territories, Canada. Relative to the 1 minute dataset, precision decreased by 23%, 46% and 60% for the 5, 10 and 15 minute datasets, respectively. Five and 10 minute sampling intervals provided unbiased equal variance estimates of 1 minute sampling, whereas 15 minute intervals were biased towards underestimation by 6%. Stratifying estimates by day and by discharge increased precision over non-stratification by 4% and 3%, respectively. Not including wood transported during ice break-up, the total minimum wood load estimated at this site is 3300 × 800$ m3 for the 2012 runoff season. The vast majority of the imprecision in total wood volumes came from variance in estimating average volume per log. Comparison of proportions and variance across sample intervals using bootstrap sampling to achieve equal n. Each trial was sampled for n=100, 10,000 times and averaged. All trials were then averaged to obtain an estimate for each sample interval. Dashed lines represent values from the one minute dataset.

  6. Robotic single port cholecystectomy (R-LESS-C): experience in 36 patients.

    Science.gov (United States)

    Uras, Cihan; Böler, Deniz Eren; Ergüner, Ilknur; Hamzaoğlu, Ismail

    2014-07-01

    Laparoendoscopic single-site surgery (LESS) has emerged as a result of a search for "pain-less" and "scar-less" surgery. Laparoendoscopic single-site cholecystectomy (LESS-C) is probably the most common application in general surgery, although it harbors certain limitations. It was proposed that the da Vinci Single-Site (Si) robotic system may overcome some of the difficulties experienced during LESS, providing three dimensional views and the ability to work in a right-handed fashion. Thirty-six robotic single port cholecystectomies (R-LESS-C) performed with the da Vinci Si robotic system are evaluated in this paper R-LESS-C performed in 36 patients were reviewed. The data related to the perioperative period (i.e., anesthesia time, operation time, docking time, and console time) was recorded prospectively, whereas the hospitalization period, postoperative visual analogue scale (VAS) pain scores were collected retrospectively. A total number of 36 patients, with a mean age of 40.1 years (21-64 years), underwent R-LESS-C. There were five men and 31 women. The mean anesthesia and operation times were 79.3 minutes (45-130 minutes) and 61.8 minutes (34-110 minutes), respectively. The mean docking time was 9.8 minutes (4-30 minutes) and the mean console time was 24.9 minutes (7-60 minutes). The mean hospital stay was 1.05 days (1-2 days) and the mean pain score (VAS) was 3.6 (2-8) in the first 24 hours. Incisional hernia was recorded in one patient. R-LESS-C can be performed reliably with acceptable operative times and safety. The da Vinci Si robotic system may ease LESS-C. Two issues should be considered for routine use: expensive resources are needed and the incidence of incisional hernia may increase. Copyright © 2013. Published by Elsevier B.V.

  7. Determination of ten pyrethroids in various fruit juices: comparison of dispersive liquid-liquid microextraction sample preparation and QuEChERS method combined with dispersive liquid-liquid microextraction.

    Science.gov (United States)

    Zhang, Yaohai; Zhang, Xuelian; Jiao, Bining

    2014-09-15

    Dispersive liquid-liquid microextraction (DLLME) sample preparation and the quick, easy, cheap, effective, rugged and safe (QuEChERS) method combined with DLLME were developed and compared for the analysis of ten pyrethroids in various fruit juices using gas chromatography-electron capture detection (GC-ECD). QuEChERS-DLLME method has found its widespread applications to all the fruit juices including those samples with more complex matrices (orange, lemon, kiwi and mango) while DLLME was confined to the fruit juices with simpler matrices (apple, pear, grape and peach). The two methods provided acceptable recoveries and repeatability. In addition, the applicabilities of two methods were demonstrated with the real samples and further confirmed by gas chromatography-mass spectrometry (GC-MS). Copyright © 2014. Published by Elsevier Ltd.

  8. [OR minute myth : Guidelines for calculation of DRG revenues per OR minute].

    Science.gov (United States)

    Waeschle, R M; Hinz, J; Bleeker, F; Sliwa, B; Popov, A; Schmidt, C E; Bauer, M

    2016-02-01

    The economic situation in German Hospitals is tense and needs the implementation of differentiated controlling instruments. Accordingly, parameters of revenue development of different organizational units within a hospital are needed. This is particularly necessary in the revenue and cost-intensive operating theater field. So far there are only barely established productivity data for the control of operating room (OR) revenues during the year available. This article describes a valid method for the calculation of case-related revenues per OR minute conform to the diagnosis-related groups (DRG).For this purpose the relevant datasets from the OR information system and the § 21 productivity report (DRG grouping) of the University Medical Center Göttingen were combined. The revenues defined in the DRG browser of the Institute for Hospital Reimbursement (InEK) were assigned to the corresponding process times--incision-suture time (SNZ), operative preparation time and anesthesiology time--according to the InEK system. All full time stationary DRG cases treated within the OR were included and differentiated according to the surgical department responsible. The cost centers "OR section" and "anesthesia" were isolated to calculate the revenues of the operating theater. SNZ clusters and cost type groups were formed to demonstrate their impact on the revenues per OR minute. A surgical personal simultaneity factor (GZF) was calculated by division of the revenues for surgeons and anesthesiologists. This factor resembles the maximum DRG financed personnel deployment for surgeons in German hospitals.The revenue per OR minute including all cost types and DRG was 16.63 €/min. The revenues ranged from 10.45 to 24.34 €/min depending on the surgical field. The revenues were stable when SNZ clusters were analyzed. The differentiation of cost type groups revealed a revenue reduction especially after exclusion of revenues for implants and infrastructure. The calculated GZF over

  9. Granulocyte colony-stimulating factor in toxic epidermal necrolysis (TEN) and Chelsea & Westminster TEN management protocol [corrected].

    Science.gov (United States)

    de Sica-Chapman, A; Williams, G; Soni, N; Bunker, C B

    2010-04-01

    Toxic epidermal necrolysis (TEN) is a rare but life-threatening, allergic drug reaction. Skin blistering with epidermal and mucosal necrolysis with subsequent detachment from an inflamed underlying dermis is a hallmark of the condition. The pathogenesis of TEN is not well understood, accounting for controversies about its management and significant delay in initiating potentially beneficial therapy. There are no management protocols based on a robust evidence base. Prompt recognition of the diagnosis and consensus on early management initiatives are necessary in order to improve outcomes and survival in TEN. To date, TEN management has been directed at arresting the allergic reaction and treating the complications. We have identified a need for specific medical interventions to accelerate wound regeneration. This approach has not previously been adopted in the management of TEN. We observed that in two cases of severe TEN, dramatic re-epithelialization and recovery coincided with the introduction of granulocyte colony-stimulating factor (G-CSF) for neutropenia. We explain how addition of the G-CSF promotes recovery from TEN by enhanced bioregeneration of the damaged tissues through accelerated re-epithelialization. G-CSF has been used for severe neutropenia in TEN, but we recommend and explain why, as in our Chelsea and Westminster protocol, G-CSF should be considered in treating severe TEN irrespective of the severity of neutropenia.

  10. The Effects of Exercise with TENS on Spasticity, Balance, and Gait in Patients with Chronic Stroke: A Randomized Controlled Trial

    OpenAIRE

    Park, Junhyuck; Seo, Dongkwon; Choi, Wonjae; Lee, Seungwon

    2014-01-01

    Background Transcutaneous electrical nerve stimulation (TENS) is a useful modality for pain control. TENS has recently been applied to decrease spasticity. The purpose of this study is to determine whether the addition of TENS to an exercise program reduces spasticity and improves balance and gait in chronic stroke patients. Material/Methods This was a single-blinded, multicenter, randomized controlled trial. Thirty-four ambulatory individuals with chronic stroke participated and were randoml...

  11. Transcutaneous electrical nerve stimulation (TENS) for chronic low-back pain.

    Science.gov (United States)

    Khadilkar, A; Milne, S; Brosseau, L; Robinson, V; Saginur, M; Shea, B; Tugwell, P; Wells, G

    2005-07-20

    -planned subgroup analyses, intended to examine the impact of different stimulation parameters, sites of TENS application, treatment durations and baseline patient characteristics were not possible due to the small number of included trials. There is inconsistent evidence to support the use of TENS as a single treatment in the management of chronic LBP. Larger, multi-center, randomized controlled trials are needed to better assess the true effectiveness of TENS. Special attention should be given to the risks and benefits of long-term use, which more appropriately addresses the realities of managing chronic low-back pain.

  12. Analysis of U and Pu resin bead samples with a single stage mass spectrometer

    International Nuclear Information System (INIS)

    Smith, D.H.; Walker, R.L.; Bertram, L.K.; Carter, J.A.

    1979-01-01

    Resin bead sampling enables the shipment of nanogram U and Pu quantities for analysis. Application of this sampling technique to safeguards was investigated with a single-stage mass spectrometer. Standards gave results in good agreement with NBS certified values. External precisions of +-0.5% were obtained on isotopic ratios of approx. 0.01; precisions on quantitative measurements are +-1.0%

  13. The analysis of the possibility of using 10-minute rainfall series to determine the maximum rainfall amount with 5 minutes duration

    Science.gov (United States)

    Kaźmierczak, Bartosz; Wartalska, Katarzyna; Wdowikowski, Marcin; Kotowski, Andrzej

    2017-11-01

    Modern scientific research in the area of heavy rainfall analysis regarding to the sewerage design indicates the need to develop and use probabilistic rain models. One of the issues that remains to be resolved is the length of the shortest amount of rain to be analyzed. It is commonly believed that the best time is 5 minutes, while the least rain duration measured by the national services is often 10 or even 15 minutes. Main aim of this paper is to present the difference between probabilistic rainfall models results given from rainfall time series including and excluding 5 minutes rainfall duration. Analysis were made for long-time period from 1961-2010 on polish meteorological station Legnica. To develop best fitted to measurement rainfall data probabilistic model 4 probabilistic distributions were used. Results clearly indicates that models including 5 minutes rainfall duration remains more appropriate to use.

  14. Simple and Reproducible Sample Preparation for Single-Shot Phosphoproteomics with High Sensitivity

    DEFF Research Database (Denmark)

    Jersie-Christensen, Rosa R.; Sultan, Abida; Olsen, Jesper V

    2016-01-01

    The traditional sample preparation workflow for mass spectrometry (MS)-based phosphoproteomics is time consuming and usually requires multiple steps, e.g., lysis, protein precipitation, reduction, alkylation, digestion, fractionation, and phosphopeptide enrichment. Each step can introduce chemical...... artifacts, in vitro protein and peptide modifications, and contaminations. Those often result in sample loss and affect the sensitivity, dynamic range and accuracy of the mass spectrometric analysis. Here we describe a simple and reproducible phosphoproteomics protocol, where lysis, denaturation, reduction......, and alkylation are performed in a single step, thus reducing sample loss and increasing reproducibility. Moreover, unlike standard cell lysis procedures the cell harvesting is performed at high temperatures (99 °C) and without detergents and subsequent need for protein precipitation. Phosphopeptides are enriched...

  15. Algebra success in 20 minutes a day

    CERN Document Server

    LearningExpress, LLC

    2014-01-01

    Stripped of unnecessary math jargon but bursting with algebra essentials, this handy guide covers vital algebra skills that apply to real-world scenarios. Whether you're new to algebra or just looking for a refresher, Algebra Success in 20 Minutes a Day offers a lesson plan that provides quick and thorough instruction in practical, critical skills. All lessons can be completed in just 20 minutes a day, for a manageable and non-intimidating learning experience.

  16. Narrow ridge waveguide high power single mode 1.3-μm InAs/InGaAs ten-layer quantum dot lasers

    Directory of Open Access Journals (Sweden)

    Cao Q

    2007-01-01

    Full Text Available AbstractTen-layer InAs/In0.15Ga0.85As quantum dot (QD laser structures have been grown using molecular beam epitaxy (MBE on GaAs (001 substrate. Using the pulsed anodic oxidation technique, narrow (2 μm ridge waveguide (RWG InAs QD lasers have been fabricated. Under continuous wave operation, the InAs QD laser (2 × 2,000 μm2 delivered total output power of up to 272.6 mW at 10 °C at 1.3 μm. Under pulsed operation, where the device heating is greatly minimized, the InAs QD laser (2 × 2,000 μm2 delivered extremely high output power (both facets of up to 1.22 W at 20 °C, at high external differential quantum efficiency of 96%. Far field pattern measurement of the 2-μm RWG InAs QD lasers showed single lateral mode operation.

  17. The Six Minute Walk Test Revisited

    Science.gov (United States)

    Mazumder, M.

    2017-12-01

    Background and Purpose: Heart failure is the leading cause of death and often alters or severely restricts human mobility, an essential life function. Motion capture is an emerging tool for analyzing human movement and extremity articulation, providing quantitative information on gait and range of motion. This study uses BioStamp mechanosensors to identify differences in motion for the duration of the Six Minute Walk Test and signature patterns of muscle contraction and posture in patients with advanced heart failure compared to healthy subjects. Identification and close follow up of these patterns may allow enhanced diagnosis and the possibility for early intervention before disease worsening. Additionally, movement parameters represent a new family of potential biomarkers to track heart failure onset, progression and therapy. Methods: Prior to the Six Minute Walk Test, BioStamps (MC10) were applied to the chest, upper and lower extremities of heart failure and healthy patients and data were streamed and recorded revealing the pattern of movement in three separate axes. Conjointly, before and after the Six Minute Walk Test, the following vitals were measured per subject: heart rate, respiratory rate, blood pressure, oxygen saturation, dyspnea and leg fatigue (self-reported with Borg scale). During the test, patients were encouraged to walk as far as they can in 6 minutes on a 30m course, as we recorded the number of laps completed and oxygen saturation every minute. Results and Conclusions: The sensors captured and quantified whole body and regional motion parameters including: a. motion extent, position, acceleration and angle via incorporated accelerometers and gyroscopes; b. muscle contraction via incorporated electromyogram (EMG). Accelerometry and gyroscopic data for the last five steps of a healthy and heart failure patient are shown. While significant differences in motion for the duration of the test were not found, each category of patients had a distinct

  18. Gastroesophageal anastomosis: single-layer versus double-layer technique

    International Nuclear Information System (INIS)

    Aslam, V.A.; Bilal, A.; Khan, A.; Ahmed, M.

    2008-01-01

    Considerable controversy exists regarding the optimum technique for gastroesophageal anastomosis. Double layer technique has long been considered important for safe healing but there is evidence that single layer technique is also safe and can be performed in much shorter time. The purpose of this study was to compare the outcome of single layer and double layer techniques for gastroesophageal anastomosis. A prospective randomized study was conducted in cardiothoracic unit, Lady Reading Hospital from Jan 2006 to Jan 2008. Fifty patients with oesophageal carcinoma undergoing subtotal oesophagectomy were randomized to have the anastomosis by single layer continuous or double layer continuous technique (group A (n=24) and B (n=26) respectively). The demographic data, operative and anastomosis time, postoperative complications and hospital mortality were recorded on a proforma and analyzed on SPSS 10. There was no significant difference between group A and B in terms of age, gender, postoperative complications and duration of hospital stay. Anastomotic leak occurred in 4.2% patients in group A and 7.7% in group B (p=NS). Mean anastomosis time was 10.04 minutes in group A and 19.2 minutes in group B (p=0.0001). Mean operative time was 163.83 minutes and 170.96 minutes in group A and B respectively. Overall hospital mortality was 2%; no deaths occurred due to anastomotic leak. Single layer continuous technique is equally safe and can be performed in shorter time and at a lower cost than the double layer technique. (author)

  19. Linguistic analysis of the Preschool Five Minute Speech Sample: what the parents of preschool children with early signs of ADHD say and how they say it?

    Directory of Open Access Journals (Sweden)

    Elvira Perez

    Full Text Available A linguistic analysis was performed on the Preschool Five Minute Speech Sample (PFMSS of 42 parents. PFMSS is a validated measure for Expressed Emotion (EE to assess parent-child relationship. Half of these parents (n = 21, clinical group had preschool children with early symptoms of attention deficit hyperactivity disorder (ADHD, the rest had typically developing children. Early symptoms of ADHD were identified with the Werry-Weiss Peters Rating Scale. The linguistic component of the PFMSS was analysed with keyword and linguistic pattern identification. The results of these two complementary analyses (i.e., EE and linguistic analysis provided relevant recommendations that may improve the efficacy of psychological treatment for ADHD such as parenting interventions. We discuss the practical implications of these findings.

  20. Transcutaneous electrical nerve stimulation: nonparallel antinociceptive effects on chronic clinical pain and acute experimental pain.

    Science.gov (United States)

    Cheing, G L; Hui-Chan, C W

    1999-03-01

    To investigate to what extent a single 60-minute session of transcutaneous electrical nerve stimulation (TENS) would modify chronic clinical pain, acute experimental pain, and the flexion reflex evoked in chronic low back pain patients. Thirty young subjects with chronic low back pain were randomly allocated to two groups, receiving either TENS or placebo stimulation to the lumbosacral region for 60 minutes. The flexion reflex was elicited by an electrical stimulation applied to the subject's right sole and recorded electromyographically from the biceps femoris and the tibialis anterior muscles. Subjective sensation of low back pain and the electrically induced pain were measured by two separate visual analog scales, termed VAS(LBP) and VAS(FR), respectively. Data obtained before, during, and 60 minutes after TENS and placebo stimulations were analyzed using repeated measures ANOVA. The VAS(LBP) score was significantly reduced to 63.1% of the prestimulation value after TENS (pTENS protocol had different degrees of antinociceptive influence on chronic and acute pain in chronic low back pain patients.

  1. High-quality bulk hybrid perovskite single crystals within minutes by inverse temperature crystallization

    KAUST Repository

    Saidaminov, Makhsud I.; Abdelhady, Ahmed L.; Banavoth, Murali; Alarousu, Erkki; Burlakov, Victor M.; Peng, Wei; Dursun, Ibrahim; Wang, Lingfei; He, Yao; Maculan, Giacomo; Goriely, Alain; Wu, Tao; Mohammed, Omar F.; Bakr, Osman

    2015-01-01

    Single crystals of methylammonium lead trihalide perovskites (MAPbX3; MA=CH3NH3+, X=Br− or I−) have shown remarkably low trap density and charge transport properties; however, growth of such high-quality semiconductors is a time-consuming process

  2. Converting MMSE to MoCA and MoCA 5-minute protocol in an educationally heterogeneous sample with stroke or transient ischemic attack.

    Science.gov (United States)

    Wong, Adrian; Black, Sandra E; Yiu, Stanley Y P; Au, Lisa W C; Lau, Alexander Y L; Soo, Yannie O Y; Chan, Anne Y Y; Leung, Thomas W H; Wong, Lawrence K S; Kwok, Timothy C Y; Cheung, Theodore C K; Leung, Kam-Tat; Lam, Bonnie Y K; Kwan, Joseph S K; Mok, Vincent C T

    2018-05-01

    The Montreal Cognitive Assessment (MoCA) is psychometrically superior over the Mini-mental State Examination (MMSE) for cognitive screening in stroke or transient ischemic attack (TIA). It is free for clinical and research use. The objective of this study is to convert scores from the MMSE to MoCA and MoCA-5-minute protocol (MoCA-5 min) and to examine the ability of the converted scores in detecting cognitive impairment after stroke or TIA. A total of 904 patients were randomly divided into training (n = 623) and validation (n = 281) samples matched for demography and cognition. MMSE scores were converted to MoCA and MoCA-5 min using (1) equipercentile method with log-linear smoothing and (2) Poisson regression adjusting for age and education. Receiver operating characteristics curve analysis was used to examine the ability of the converted scores in differentiating patients with cognitive impairment. The mean education was 5.8 (SD = 4.6; ranged 0-20) years. The entire spectrum of MMSE scores was converted to MoCA and MoCA-5 min using equipercentile method. Relationship between MMSE and MoCA scores was confounded by age and education, and a conversion equation with adjustment for age and education was derived. In the validation sample, the converted scores differentiated cognitively impaired patients with area under receiver operating characteristics curve 0.826 to 0.859. We provided 2 methods to convert scores from the MMSE to MoCA and MoCA-5 min based on a large sample of patients with stroke or TIA having a wide range of education and cognitive levels. The converted scores differentiated patients with cognitive impairment after stroke or TIA with high accuracy. Copyright © 2018 John Wiley & Sons, Ltd.

  3. Efficacy of the use of two simultaneously TENS devices for fibromyalgia pain.

    Science.gov (United States)

    Lauretti, Gabriela Rocha; Chubaci, Eliana Fazuoli; Mattos, Anita Leocadia

    2013-08-01

    Fibromyalgia is characterized by a range of symptoms that include muscle pain, fatigue and sleep disorders. Transcutaneous electrical nerve stimulation (TENS) is an established method for pain relief. The purpose of the study was to evaluate the effectiveness and safety of the use of two simultaneously new TENS devices for fibromyalgia pain. After Ethics approval and informed consent, 39 patients were prospectively divided into three groups to evaluate TENS device, applied simultaneously in each patient: (1) at the lower back (perpendicular to the vertebrae canal, at the level of the 5th lumbar vertebrae) and (2) centrally above and below the space between the C7 and T1 spinous processes. The devices were applied for 20 min at 12-h interval during 7 consecutive days. For the placebo group (PG), the devices did not transmitted electrical stimulus. The single-TENS group (STG) (n = 13) had one active and one placebo TENS. The DTG applied both active TENS devices at the low back and cervical areas. Diclofenac was used as rescue analgesic. The efficacy measures were pain relief, reduction in use of daily analgesic tablets, quality of sleep and fatigue. The evaluation within groups revealed that patients from DPG refereed no pain relief when compared to their previous VAS pain score (8 cm, p > 0.05), while patients from the STG refereed improvement of 2.5 cm in the pain VAS (previous 8.5 cm compared to 6 cm after treatment) (p pain (previous 8.5-4.3 cm) (p STG > PG (p TENS improved pain relief in fibromyalgia pain, pain and fatigue were further improved when two active devices were simultaneously applied at the low back and cervical area, with no side effects.

  4. Prospective assessment of the false positive rate of the Australian snake venom detection kit in healthy human samples.

    Science.gov (United States)

    Nimorakiotakis, Vasilios Bill; Winkel, Kenneth D

    2016-03-01

    The Snake Venom Detection Kit (SVDK; bioCSL Pty Ltd, Australia) distinguishes venom from the five most medically significant snake immunotypes found in Australia. This study assesses the rate of false positives that, by definition, refers to a positive assay finding in a sample from someone who has not been bitten by a venomous snake. Control unbroken skin swabs, simulated bite swabs and urine specimens were collected from 61 healthy adult volunteers [33 males and 28 females] for assessment. In all controls, simulated bite site and urine samples [a total of 183 tests], the positive control well reacted strongly within one minute and no test wells reacted during the ten minute incubation period. However, in two urine tests, the negative control well gave a positive reaction (indicating an uninterpretable test). A 95% confidence interval for the false positive rate, on a per-patient rate, derived from the findings of this study, would extend from 0% to 6% and, on a per-test basis, it would be 0-2%. It appears to be a very low incidence (0-6%) of intrinsic true false positives for the SVDK. The clinical impresssion of a high SVDK false positive rate may be mostly related to operator error. Crown Copyright © 2015. Published by Elsevier Ltd. All rights reserved.

  5. Geometry success in 20 minutes a day

    CERN Document Server

    LLC, LearningExpress

    2014-01-01

    Whether you're new to geometry or just looking for a refresher, Geometry Success in 20 Minutes a Day offers a 20-step lesson plan that provides quick and thorough instruction in practical, critical skills. Stripped of unnecessary math jargon but bursting with geometry essentials, Geometry Success in 20 Minutes a Day: Covers all vital geometry skills, from the basic building blocks of geometry to ratio, proportion, and similarity to trigonometry and beyond Provides hundreds of practice exercises in test format Applies geometr

  6. Diagnosing phenotypes of single-sample individuals by edge biomarkers.

    Science.gov (United States)

    Zhang, Wanwei; Zeng, Tao; Liu, Xiaoping; Chen, Luonan

    2015-06-01

    Network or edge biomarkers are a reliable form to characterize phenotypes or diseases. However, obtaining edges or correlations between molecules for an individual requires measurement of multiple samples of that individual, which are generally unavailable in clinical practice. Thus, it is strongly demanded to diagnose a disease by edge or network biomarkers in one-sample-for-one-individual context. Here, we developed a new computational framework, EdgeBiomarker, to integrate edge and node biomarkers to diagnose phenotype of each single test sample. By applying the method to datasets of lung and breast cancer, it reveals new marker genes/gene-pairs and related sub-networks for distinguishing earlier and advanced cancer stages. Our method shows advantages over traditional methods: (i) edge biomarkers extracted from non-differentially expressed genes achieve better cross-validation accuracy of diagnosis than molecule or node biomarkers from differentially expressed genes, suggesting that certain pathogenic information is only present at the level of network and under-estimated by traditional methods; (ii) edge biomarkers categorize patients into low/high survival rate in a more reliable manner; (iii) edge biomarkers are significantly enriched in relevant biological functions or pathways, implying that the association changes in a network, rather than expression changes in individual molecules, tend to be causally related to cancer development. The new framework of edge biomarkers paves the way for diagnosing diseases and analyzing their molecular mechanisms by edges or networks in one-sample-for-one-individual basis. This also provides a powerful tool for precision medicine or big-data medicine. © The Author (2015). Published by Oxford University Press on behalf of Journal of Molecular Cell Biology, IBCB, SIBS, CAS. All rights reserved.

  7. Water-tight knee arthrotomy closure: comparison of a novel single bidirectional barbed self-retaining running suture versus conventional interrupted sutures.

    Science.gov (United States)

    Nett, Michael; Avelar, Rui; Sheehan, Michael; Cushner, Fred

    2011-03-01

    Standard medial parapatellar arthrotomies of 10 cadaveric knees were closed with either conventional interrupted absorbable sutures (control group, mean of 19.4 sutures) or a single running knotless bidirectional barbed absorbable suture (experimental group). Water-tightness of the arthrotomy closure was compared by simulating a tense hemarthrosis and measuring arthrotomy leakage over 3 minutes. Mean total leakage was 356 mL and 89 mL in the control and experimental groups, respectively (p = 0.027). Using 8 of the 10 knees (4 closed with control sutures, 4 closed with an experimental suture), a tense hemarthrosis was again created, and iatrogenic suture rupture was performed: a proximal suture was cut at 1 minute; a distal suture was cut at 2 minutes. The impact of suture rupture was compared by measuring total arthrotomy leakage over 3 minutes. Mean total leakage was 601 mL and 174 mL in the control and experimental groups, respectively (p = 0.3). In summary, using a cadaveric model, arthrotomies closed with a single bidirectional barbed running suture were statistically significantly more water-tight than those closed using a standard interrupted technique. The sample size was insufficient to determine whether the two closure techniques differed in leakage volume after suture rupture.

  8. High-quality bulk hybrid perovskite single crystals within minutes by inverse temperature crystallization

    KAUST Repository

    Saidaminov, Makhsud I.

    2015-07-06

    Single crystals of methylammonium lead trihalide perovskites (MAPbX3; MA=CH3NH3+, X=Br− or I−) have shown remarkably low trap density and charge transport properties; however, growth of such high-quality semiconductors is a time-consuming process. Here we present a rapid crystal growth process to obtain MAPbX3 single crystals, an order of magnitude faster than previous reports. The process is based on our observation of the substantial decrease of MAPbX3 solubility, in certain solvents, at elevated temperatures. The crystals can be both size- and shape-controlled by manipulating the different crystallization parameters. Despite the rapidity of the method, the grown crystals exhibit transport properties and trap densities comparable to the highest quality MAPbX3 reported to date. The phenomenon of inverse or retrograde solubility and its correlated inverse temperature crystallization strategy present a major step forward for advancing the field on perovskite crystallization.

  9. The effects of spatial sampling choices on MR temperature measurements.

    Science.gov (United States)

    Todd, Nick; Vyas, Urvi; de Bever, Josh; Payne, Allison; Parker, Dennis L

    2011-02-01

    The purpose of this article is to quantify the effects that spatial sampling parameters have on the accuracy of magnetic resonance temperature measurements during high intensity focused ultrasound treatments. Spatial resolution and position of the sampling grid were considered using experimental and simulated data for two different types of high intensity focused ultrasound heating trajectories (a single point and a 4-mm circle) with maximum measured temperature and thermal dose volume as the metrics. It is demonstrated that measurement accuracy is related to the curvature of the temperature distribution, where regions with larger spatial second derivatives require higher resolution. The location of the sampling grid relative temperature distribution has a significant effect on the measured values. When imaging at 1.0 × 1.0 × 3.0 mm(3) resolution, the measured values for maximum temperature and volume dosed to 240 cumulative equivalent minutes (CEM) or greater varied by 17% and 33%, respectively, for the single-point heating case, and by 5% and 18%, respectively, for the 4-mm circle heating case. Accurate measurement of the maximum temperature required imaging at 1.0 × 1.0 × 3.0 mm(3) resolution for the single-point heating case and 2.0 × 2.0 × 5.0 mm(3) resolution for the 4-mm circle heating case. Copyright © 2010 Wiley-Liss, Inc.

  10. Area G perimeter surface-soil and single-stage water sampling. Environmental surveillance for fiscal year 95. Progress report

    International Nuclear Information System (INIS)

    Childs, M.; Conrad, R.

    1997-09-01

    ESH-19 personnel collected soil and single-stage water samples around the perimeter of Area G at Los Alamos National Laboratory (LANL) during FY 95 to characterize possible radionuclide movement out of Area G through surface water and entrained sediment runoff. Soil samples were analyzed for tritium, total uranium, isotopic plutonium, americium-241, and cesium-137. The single-stage water samples were analyzed for tritium and plutonium isotopes. All radiochemical data was compared with analogous samples collected during FY 93 and 94 and reported in LA-12986 and LA-13165-PR. Six surface soils were also submitted for metal analyses. These data were included with similar data generated for soil samples collected during FY 94 and compared with metals in background samples collected at the Area G expansion area

  11. Brief communication: Is variation in the cranial capacity of the Dmanisi sample too high to be from a single species?

    Science.gov (United States)

    Lee, Sang-Hee

    2005-07-01

    This study uses data resampling to test the null hypothesis that the degree of variation in the cranial capacity of the Dmanisi hominid sample is within the range variation of a single species. The statistical significance of the variation in the Dmanisi sample is examined using simulated distributions based on comparative samples of modern humans, chimpanzees, and gorillas. Results show that it is unlikely to find the maximum difference observed in the Dmanisi sample in distributions of female-female pairs from comparative single-species samples. Given that two sexes are represented, the difference in the Dmanisi sample is not enough to reject the null hypothesis of a single species. Results of this study suggest no compelling reason to invoke multiple taxa to explain variation in the cranial capacity of the Dmanisi hominids. (c) 2004 Wiley-Liss, Inc

  12. Single Molecule Nano-Metronome

    Science.gov (United States)

    Buranachai, Chittanon; McKinney, Sean A.; Ha, Taekjip

    2008-01-01

    We constructed a DNA-based nano-mechanical device called the nano-metronome. Our device is made by introducing complementary single stranded overhangs at the two arms of the DNA four-way junction. The ticking rates of this stochastic metronome depend on ion concentrations and can be changed by a set of DNA-based switches to deactivate/reactivate the sticky end. Since the device displays clearly distinguishable responses even with a single basepair difference, it may lead to a single molecule sensor of minute sequence differences of a target DNA. PMID:16522050

  13. Single ventricle cardiac defect

    International Nuclear Information System (INIS)

    Eren, B.; Turkmen, N.; Fedakar, R.; Cetin, V.

    2010-01-01

    Single ventricle heart is defined as a rare cardiac abnormality with a single ventricle chamber involving diverse functional and physiological defects. Our case is of a ten month-old baby boy who died shortly after admission to the hospital due to vomiting and diarrhoea. Autopsy findings revealed cyanosis of finger nails and ears. Internal examination revealed; large heart, weighing 60 grams, single ventricle, without a septum and upper membranous part. Single ventricle is a rare pathology, hence, this paper aims to discuss this case from a medico-legal point of view. (author)

  14. The DECam Minute Cadence Survey

    Science.gov (United States)

    Belardi, C.; Kilic, M.; Munn, J. A.; Gianninas, A.; Barber, S. D.; Dey, A.; Stetson, P. B.

    2017-03-01

    We present the first results from a minute cadence survey of a 3 deg2 field obtained with the Dark Energy Camera. We imaged part of the Canada- France-Hawaii Telescope Legacy Survey area over eight half-nights. We use the stacked images to identify 111 high proper motion white dwarf candidates with g≤ 24.5 mag and search for eclipse-like events and other sources of variability. We find a new g=20.64 mag pulsating ZZ Ceti star with pulsation periods of 11-13 min. However, we do not find any transiting planetary companions in the habitable zone of our target white dwarfs. Given the probability of eclipses of 1% and our observing window from the ground, the non-detection of such companions in this first field is not surprising. Minute cadence DECam observations of additional fields will provide stringent constraints on the frequency of planets in the white dwarf habitable zone.

  15. Spectroscopic Evolution of Disintegrating Planetesimals: Minute to Month Variability in the Circumstellar Gas Associated with WD 1145+017

    Energy Technology Data Exchange (ETDEWEB)

    Redfield, Seth; Cauley, P. Wilson; Duvvuri, Girish M. [Astronomy Department and Van Vleck Observatory, Wesleyan University, Middletown, CT 06459 (United States); Farihi, Jay [Department of Physics and Astronomy, University College London, London WC1E 6BT (United Kingdom); Parsons, Steven G. [Department of Physics and Astronomy, University of Sheffield, Sheffield, S3 7RH (United Kingdom); Gänsicke, Boris T., E-mail: sredfield@wesleyan.edu [Department of Physics, University of Warwick, Coventry CV4 7AL (United Kingdom)

    2017-04-10

    With the recent discovery of transiting planetary material around WD 1145+017, a critical target has been identified that links the evolution of planetary systems with debris disks and their accretion onto the star. We present a series of observations, five epochs over a year, taken with Keck and the VLT, which for the first time show variability of circumstellar absorption in the gas disk surrounding WD 1145+017 on timescales of minutes to months. Circumstellar absorption is measured in more than 250 lines of 14 ions among 10 different elements associated with planetary composition, e.g., O, Mg, Ca, Ti, Cr, Mn, Fe, and Ni. Broad circumstellar gas absorption with a velocity spread of 225 km s{sup −1} is detected, but over the course of a year blueshifted absorption disappears, while redshifted absorption systematically increases. A correlation of equivalent width and oscillator strength indicates that the gas is not highly optically thick (median τ ≈ 2). We discuss simple models of an eccentric disk coupled with magnetospheric accretion to explain the basic observed characteristics of these high-resolution and high signal-to-noise observations. Variability is detected on timescales of minutes in the two most recent observations, showing a loss of redshifted absorption for tens of minutes, coincident with major transit events and consistent with gas hidden behind opaque transiting material. This system currently presents a unique opportunity to learn how the gas causing the spectroscopic, circumstellar absorption is associated with the ongoing accretion evidenced by photospheric contamination, as well as the transiting planetary material detected in photometric observations.

  16. Minute ventilation of cyclists, car and bus passengers: an experimental study

    Directory of Open Access Journals (Sweden)

    Hazel Peter

    2009-10-01

    Full Text Available Abstract Background Differences in minute ventilation between cyclists, pedestrians and other commuters influence inhaled doses of air pollution. This study estimates minute ventilation of cyclists, car and bus passengers, as part of a study on health effects of commuters' exposure to air pollutants. Methods Thirty-four participants performed a submaximal test on a bicycle ergometer, during which heart rate and minute ventilation were measured simultaneously at increasing cycling intensity. Individual regression equations were calculated between heart rate and the natural log of minute ventilation. Heart rates were recorded during 280 two hour trips by bicycle, bus and car and were calculated into minute ventilation levels using the individual regression coefficients. Results Minute ventilation during bicycle rides were on average 2.1 times higher than in the car (individual range from 1.3 to 5.3 and 2.0 times higher than in the bus (individual range from 1.3 to 5.1. The ratio of minute ventilation of cycling compared to travelling by bus or car was higher in women than in men. Substantial differences in regression equations were found between individuals. The use of individual regression equations instead of average regression equations resulted in substantially better predictions of individual minute ventilations. Conclusion The comparability of the gender-specific overall regression equations linking heart rate and minute ventilation with one previous American study, supports that for studies on the group level overall equations can be used. For estimating individual doses, the use of individual regression coefficients provides more precise data. Minute ventilation levels of cyclists are on average two times higher than of bus and car passengers, consistent with the ratio found in one small previous study of young adults. The study illustrates the importance of inclusion of minute ventilation data in comparing air pollution doses between

  17. Minute ventilation of cyclists, car and bus passengers: an experimental study.

    Science.gov (United States)

    Zuurbier, Moniek; Hoek, Gerard; van den Hazel, Peter; Brunekreef, Bert

    2009-10-27

    Differences in minute ventilation between cyclists, pedestrians and other commuters influence inhaled doses of air pollution. This study estimates minute ventilation of cyclists, car and bus passengers, as part of a study on health effects of commuters' exposure to air pollutants. Thirty-four participants performed a submaximal test on a bicycle ergometer, during which heart rate and minute ventilation were measured simultaneously at increasing cycling intensity. Individual regression equations were calculated between heart rate and the natural log of minute ventilation. Heart rates were recorded during 280 two hour trips by bicycle, bus and car and were calculated into minute ventilation levels using the individual regression coefficients. Minute ventilation during bicycle rides were on average 2.1 times higher than in the car (individual range from 1.3 to 5.3) and 2.0 times higher than in the bus (individual range from 1.3 to 5.1). The ratio of minute ventilation of cycling compared to travelling by bus or car was higher in women than in men. Substantial differences in regression equations were found between individuals. The use of individual regression equations instead of average regression equations resulted in substantially better predictions of individual minute ventilations. The comparability of the gender-specific overall regression equations linking heart rate and minute ventilation with one previous American study, supports that for studies on the group level overall equations can be used. For estimating individual doses, the use of individual regression coefficients provides more precise data. Minute ventilation levels of cyclists are on average two times higher than of bus and car passengers, consistent with the ratio found in one small previous study of young adults. The study illustrates the importance of inclusion of minute ventilation data in comparing air pollution doses between different modes of transport.

  18. TMPRSS2-ERG gene fusion status in minute (minimal) prostatic adenocarcinoma.

    Science.gov (United States)

    Albadine, Roula; Latour, Mathieu; Toubaji, Antoun; Haffner, Michael; Isaacs, William B; A Platz, Elizabeth; Meeker, Alan K; Demarzo, Angelo M; Epstein, Jonathan I; Netto, George J

    2009-11-01

    Minute prostatic adenocarcinomas are considered to be of insufficient virulence. Given recent suggestions of TMPRSS2-ERG gene fusion association with aggressive prostatic adenocarcinoma, we evaluated the incidence of TMPRSS2-ERG fusion in minute prostatic adenocarcinomas. A total of 45 consecutive prostatectomies with minute adenocarcinoma were used for tissue microarray construction. A total of 63 consecutive non-minimal, Gleason Score 6 tumors, from a separate PSA Era prostatectomy tissue microarray, were used for comparison. FISH was carried out using ERG break-apart probes. Tumors were assessed for fusion by deletion (Edel) or split (Esplit), duplicated fusions and low-level copy number gain in normal ERG gene locus. Minute adenocarcinomas: Fusion was evaluable in 32/45 tumors (71%). Fifteen out of 32 (47%) tumors were positive for fusion. Six (19%) were of the Edel class and 7 (22%) were classified as combined Edel+Esplit. Non-minute adenocarcinomas (pT2): Fusion was identified in 20/30 tumors (67%). Four (13%) were of Edel class and 5 (17%) were combined Edel+Esplit. Duplicated fusions were encountered in 5 (16%) tumors. Non-minute adenocarcinomas (pT3): Fusion was identified in 19/33 (58%). Fusion was due to a deletion in 6 (18%) tumors. Seven tumors (21%) were classified as combined Edel+Esplit. One tumor showed Esplit alone. Duplicated fusions were encountered in 3 (9%) cases. The incidence of duplicated fusions was higher in non-minute adenocarcinomas (13 vs 0%; P=0.03). A trend for higher incidence of low-level copy number gain in normal ERG gene locus without fusion was noted in non-minute adenocarcinomas (10 vs 0%; P=0.07). We found a TMPRSS2-ERG fusion rate of 47% in minute adenocarcinomas. The latter is not significantly different from that of grade matched non-minute adenocarcinomas. The incidence of duplicated fusion was higher in non-minute adenocarcinomas. Our finding of comparable rate of TMPRSS2-ERG fusion in minute adenocarcinomas may argue

  19. Mile-A-Minute (Pest Alert)

    Science.gov (United States)

    Denise Binion; William Jackson

    2009-01-01

    Mile-a-minute weed (Persicaria perfoliata (L.) H. Gross, formerly Polygonum perfoliatum, L.) is an annual vine in the Polygonaceae or Buckwheat family. It is native to eastern Asia including India, Bhutan, Nepal, China, Burma, Japan, Korea, Indonesia, Bangladesh, Siberia, the Philippines, New Guinea, the Malay peninsula and the...

  20. Evidence for the different physiological significance of the 6- and 2-minute walk tests in multiple sclerosis

    Directory of Open Access Journals (Sweden)

    Motl Robert W

    2012-03-01

    Full Text Available Abstract Background Researchers have recently advocated for the 2-minute walk (2MW as an alternative for the 6-minute walk (6MW to assess long distance ambulation in persons with multiple sclerosis (MS. This recommendation has not been based on physiological considerations such as the rate of oxygen consumption (V·O2 over the 6MW range. Objective This study examined the pattern of change in V·O2 over the range of the 6MW in a large sample of persons with MS who varied as a function of disability status. Method Ninety-five persons with clinically-definite MS underwent a neurological examination for generating an Expanded Disability Status Scale (EDSS score, and then completion of the 6MW protocol while wearing a portable metabolic unit and an accelerometer. Results There was a time main effect on V·O2 during the 6MW (p = .0001 such that V·O2 increased significantly every 30 seconds over the first 3 minutes of the 6MW, and then remained stable over the second 3 minutes of the 6MW. This occurred despite no change in cadence across the 6MW (p = .84. Conclusions The pattern of change in V·O2 indicates that there are different metabolic systems providing energy for ambulation during the 6MW in MS subjects and steady state aerobic metabolism is reached during the last 3 minutes of the 6MW. By extension, the first 3 minutes would represent a test of mixed aerobic and anaerobic work, whereas the second 3 minutes would represent a test of aerobic work during walking.

  1. Stability in the rumen and effect on plasma status of single oral doses of vitamin D and vitamin E in high-yielding dairy cows

    DEFF Research Database (Denmark)

    Hymøller, Lone; Jensen, Søren Krogh

    2010-01-01

    The ruminal fate of the fat-soluble vitamins D and E was studied in dairy cows. Ten to 15 kg of ruminal contents was taken from each cow through a ruminal fistula. A sample was taken out (0-h sample) and the rest of the contents were mixed with 4,360 mg of all-rac-α-tocopheryl acetate (vitamin E;...... a single dose of α-tocopheryl acetate led to the conclusion that oral single dose therapy with all-rac-α-tocopheryl acetate is of limited physiological value....

  2. Effect of burst TENS and conventional TENS combined with cryotherapy on pressure pain threshold: randomised, controlled, clinical trial.

    Science.gov (United States)

    Macedo, L B; Josué, A M; Maia, P H B; Câmara, A E; Brasileiro, J S

    2015-06-01

    To assess the immediate effect of conventional and burst transcutaneous electrical nerve stimulation (TENS) in combination with cryotherapy on pain threshold and tolerance in healthy individuals. Randomised, controlled trial. University laboratory. One hundred and twelve healthy women. Volunteers were allocated at random to seven groups (n=16): (1) control, (2) placebo TENS, (3) conventional TENS, (4) burst TENS, (5) cryotherapy, (6) cryotherapy in combination with burst TENS, and (7) cryotherapy in combination with conventional TENS. Pain threshold and tolerance were measured by applying a pressure algometer at the lateral epicondyle of the humerus, before and after each intervention. The primary outcome measure was pressure pain threshold. A significant increase in pain threshold and tolerance at the 5% level of significance was recorded as follows: burst TENS {pain threshold: mean difference 1.3 [95% confidence interval (CI) 1.4 to 1.2]; pain tolerance: mean difference 3.8 (95% CI 3.9 to 3.7)}, cryotherapy [pain threshold: mean difference 1.3 (95% CI 1.4 to 1.2); pain tolerance: mean difference 1.9 (95% CI 1.8 to 2.0)] and cryotherapy in combination with burst TENS [pain threshold: mean difference 2.6 (95% CI 2.4 to 2.8); pain tolerance: mean difference 4.9 (95% CI 5.0 to 4.8)]. Cryotherapy in combination with burst TENS provided greater analgesia compared with the other groups (Pcryotherapy in combination with burst TENS to reduce induced pain, and suggest a potentiating effect when these techniques are combined. No such association was found between cryotherapy and conventional TENS. Copyright © 2014 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.

  3. TENS (transcutaneous electrical nerve stimulation) for labour pain.

    Science.gov (United States)

    Francis, Richard

    2012-05-01

    Because TENS is applied inconsistently and not always in line with optimal TENS application theory, this may explain why TENS for labour pain appears to be effective in some individuals and not in others. This article reviews TENS theory, advises upon optimal TENS application for labour pain and discusses some of the limitations of TENS research on labour pain. TENS application for labour pain may include TENS applied to either side of the lower spine, set to 200 mus pulse duration and 100 pulses per second. As pain increases, TENS intensity should be increased and as pain decreases, TENS intensity should be reduced to maintain a strong but pain free intensity of stimulation. This application may particularly reduce back pain during labour.

  4. Analysis of multiple single nucleotide polymorphisms (SNP) on DNA traces from plasma and dried blood samples

    NARCIS (Netherlands)

    Catsburg, Arnold; van der Zwet, Wil C.; Morre, Servaas A.; Ouburg, Sander; Vandenbroucke-Grauls, Christina M. J. E.; Savelkoul, Paul H. M.

    2007-01-01

    Reliable analysis of single nucleotide polymorphisms (SNPs) in DNA derived from samples containing low numbers of cells or from suboptimal sources can be difficult. A new procedure to characterize multiple SNPs in traces of DNA from plasma and old dried blood samples was developed. Six SNPs in the

  5. Treatment of chronic back pain by sensory discrimination training. A Phase I RCT of a novel device (FairMed vs. TENS

    Directory of Open Access Journals (Sweden)

    Sackley Catherine M

    2008-06-01

    Full Text Available Abstract Background The causes of chronic low back pain (CLBP remain obscure and effective treatment of symptoms remains elusive. A mechanism of relieving chronic pain based on the consequences of conflicting unpleasant sensory inputs to the central nervous system has been hypothesised. As a result a device was generated to deliver sensory discrimination training (FairMed, and this randomised controlled trial compared therapeutic effects with a comparable treatment modality, TENS. Methods 60 patients with CLBP were recruited from physiotherapy referrals to a single-blinded, randomised controlled, non-inferiority trial. They were randomised to receive either FairMed or TENS and asked to use the allocated device for 30 minutes, twice a day, for 3 weeks. The primary outcome variable measured at 0 and 3 weeks was pain intensity measured using a visual analogue scale averaged over 7 days. Secondary outcome measures were Oswestry Disability Index, 3 timed physical tests, 4 questionnaires assessing different aspects of emotional coping and a global measure of patient rating of change. Data were analysed for the difference in change of scores between groups using one-way ANOVA. Results Baseline characteristics of the two groups were comparable. The primary outcome, change in pain intensity (VAS at 3 weeks showed a mean difference between groups of -0.1, (non significant p = 0.82. The mean difference in change in ODI scores was 0.4; (non significant p = 0.85. Differences in change of physical functioning showed that no significant difference in change of scores for any of these test (p = 0.58 – 0.90. Changes in scores of aspects of emotional coping also demonstrated no significant difference in change scores between the groups (p = 0.14 – 0.94. Conclusion FairMed was not inferior to TENS treatment. The findings have implications for further research on current chronic pain theories and treatments. Further work to explore these mechanisms is important

  6. Treatment of chronic back pain by sensory discrimination training. A Phase I RCT of a novel device (FairMed) vs. TENS.

    Science.gov (United States)

    Barker, Karen L; Elliott, Christopher J; Sackley, Catherine M; Fairbank, Jeremy C T

    2008-06-28

    The causes of chronic low back pain (CLBP) remain obscure and effective treatment of symptoms remains elusive. A mechanism of relieving chronic pain based on the consequences of conflicting unpleasant sensory inputs to the central nervous system has been hypothesised. As a result a device was generated to deliver sensory discrimination training (FairMed), and this randomised controlled trial compared therapeutic effects with a comparable treatment modality, TENS. 60 patients with CLBP were recruited from physiotherapy referrals to a single-blinded, randomised controlled, non-inferiority trial. They were randomised to receive either FairMed or TENS and asked to use the allocated device for 30 minutes, twice a day, for 3 weeks. The primary outcome variable measured at 0 and 3 weeks was pain intensity measured using a visual analogue scale averaged over 7 days. Secondary outcome measures were Oswestry Disability Index, 3 timed physical tests, 4 questionnaires assessing different aspects of emotional coping and a global measure of patient rating of change. Data were analysed for the difference in change of scores between groups using one-way ANOVA. Baseline characteristics of the two groups were comparable. The primary outcome, change in pain intensity (VAS) at 3 weeks showed a mean difference between groups of -0.1, (non significant p = 0.82). The mean difference in change in ODI scores was 0.4; (non significant p = 0.85). Differences in change of physical functioning showed that no significant difference in change of scores for any of these test (p = 0.58 - 0.90). Changes in scores of aspects of emotional coping also demonstrated no significant difference in change scores between the groups (p = 0.14 - 0.94). FairMed was not inferior to TENS treatment. The findings have implications for further research on current chronic pain theories and treatments. Further work to explore these mechanisms is important to expand our understanding of chronic pain and the role of

  7. Xanthine oxidase activity is associated with risk factors for cardiovascular disease and inflammatory and oxidative status markers in metabolic syndrome: effects of a single exercise session.

    Science.gov (United States)

    Feoli, Ana Maria Pandolfo; Macagnan, Fabrício Edler; Piovesan, Carla Haas; Bodanese, Luiz Carlos; Siqueira, Ionara Rodrigues

    2014-01-01

    The main goal of the present study was to investigate the xanthine oxidase (XO) activity in metabolic syndrome in subjects submitted to a single exercise session. We also investigated parameters of oxidative and inflammatory status. A case-control study (9 healthy and 8 MS volunteers) was performed to measure XO, superoxide dismutase (SOD), glutathione peroxidase activities, lipid peroxidation, high-sensitivity C-reactive protein (hsCRP) content, glucose levels, and lipid profile. Body mass indices, abdominal circumference, systolic and diastolic blood pressure, and TG levels were also determined. The exercise session consisted of 3 minutes of stretching, 3 minutes of warm-up, 30 minutes at a constant dynamic workload at a moderate intensity, and 3 minutes at a low speed. The blood samples were collected before and 15 minutes after the exercise session. Serum XO activity was higher in MS group compared to control group. SOD activity was lower in MS subjects. XO activity was correlated with SOD, abdominal circumference, body mass indices, and hsCRP. The single exercise session reduced the SOD activity in the control group. Our data support the association between oxidative stress and risk factors for cardiovascular diseases and suggest XO is present in the pathogenesis of metabolic syndrome.

  8. Xanthine Oxidase Activity Is Associated with Risk Factors for Cardiovascular Disease and Inflammatory and Oxidative Status Markers in Metabolic Syndrome: Effects of a Single Exercise Session

    Directory of Open Access Journals (Sweden)

    Ana Maria Pandolfo Feoli

    2014-01-01

    Full Text Available Objective. The main goal of the present study was to investigate the xanthine oxidase (XO activity in metabolic syndrome in subjects submitted to a single exercise session. We also investigated parameters of oxidative and inflammatory status. Materials/Methods. A case-control study (9 healthy and 8 MS volunteers was performed to measure XO, superoxide dismutase (SOD, glutathione peroxidase activities, lipid peroxidation, high-sensitivity C-reactive protein (hsCRP content, glucose levels, and lipid profile. Body mass indices, abdominal circumference, systolic and diastolic blood pressure, and TG levels were also determined. The exercise session consisted of 3 minutes of stretching, 3 minutes of warm-up, 30 minutes at a constant dynamic workload at a moderate intensity, and 3 minutes at a low speed. The blood samples were collected before and 15 minutes after the exercise session. Results. Serum XO activity was higher in MS group compared to control group. SOD activity was lower in MS subjects. XO activity was correlated with SOD, abdominal circumference, body mass indices, and hsCRP. The single exercise session reduced the SOD activity in the control group. Conclusions. Our data support the association between oxidative stress and risk factors for cardiovascular diseases and suggest XO is present in the pathogenesis of metabolic syndrome.

  9. Complete supine percutaneous nephrolithotomy with GoPro®. Ten steps for success.

    Science.gov (United States)

    Vicentini, Fabio Carvalho; Dos Santos, Hugo Daniel Barone; Batagello, Carlos Alfredo; Amundson, Julia Rothe; Oliveira, Evaristo Peixoto; Marchini, Giovanni Scala; Srougi, Miguel; Nahas, Willian Carlos; Mazzucchi, Eduardo

    2018-03-15

    To show a video of a complete supine Percutaneous Nephrolithotomy (csPCNL) performed for the treatment of a staghorn calculus, from the surgeon's point of view. The procedure was recorded with a GoPro® camera, demonstrating the ten essential steps for a successful procedure. The patient was a 38 years-old woman with 2.4cm of left kidney lower pole stone burden who presented with 3 months of lumbar pain and recurrent urinary tract infections. She had a previous diagnosis of polycystic kidney disease and chronic renal failure stage 2. CT scan showed two 1.2cm stones in the lower pole (Guy's Stone Score 2). She had a previous ipsilateral double J insertion due to an obstructive pyelonephritis. The csPCNL was uneventful with a single access in the lower pole. The surgeon had a Full HD GoPro Hero 4 Session® camera mounted on his head, controlled by the surgical team with a remote control. All of the mains steps were recorded. Informed consent was obtained prior to the procedure. The surgical time was 90 minutes. Hemoglobin drop was 0.5g/dL. A post-operative CT scan was stone-free. The patient was discharged 36 hours after surgery. The camera worked properly and didn't cause pain or muscle discomfort to the surgeon. The quality of the recorded movie was excellent. GoPro® camera proved to be a very interesting tool to document surgeries without interfering with the procedure and with great educational potential. More studies should be conducted to evaluate the role of this equipment. Copyright® by the International Brazilian Journal of Urology.

  10. Factors associated with the 6-minute walk test in nursing home residents and community-dwelling older adults

    Science.gov (United States)

    Caballer, Vicent-Benavent; Lisón, Juan Francisco; Rosado-Calatayud, Pedro; Amer-Cuenca, Juan José; Segura-Orti, Eva

    2015-01-01

    [Purpose] The main objective of this study was to determine the contributions and extent to which certain physical measurements explain performance in the 6-minute walk test in healthy older adults living in a geriatric nursing home and for older adults dwelling in the community. [Subjects] The subjects were 122 adults aged 65 and older with no cognitive impairment who were independent in their daily activities. [Methods] The 6-minute walk test, age, body mass index, walking speed, chair stand test, Berg Balance Scale, Timed Up-and-Go test, rectus femoris cross-sectional area, Short Physical Performance Battery, and hand-grip strength were examined. [Results] Strong significant associations were found between mobility, lower-limb function, balance, and the 6-minute walk test. A stepwise multiple regression on the entire sample showed that lower-limb function was a significant and independent predictor for the 6-minute walk test. Additionally, lower-limb function was a strong predictor for the 6-minute walk test in our nursing home group, whereas mobility was found to be the best predictor in our community-dwelling group. [Conclusion] Better lower-limb function, balance, and mobility result in a higher distance covered by healthy older adults. Lower-limb function and mobility appeared to best determine walking performance in the nursing home and community-dwelling groups, respectively. PMID:26696740

  11. Secular trends: a ten-year comparison of the amount and type of physical activity and inactivity of random samples of adolescents in the Czech Republic

    Directory of Open Access Journals (Sweden)

    Frömel Karel

    2011-09-01

    Full Text Available Abstract Background An optimal level of physical activity (PA in adolescence influences the level of PA in adulthood. Although PA declines with age have been demonstrated repeatedly, few studies have been carried out on secular trends. The present study assessed levels, types and secular trends of PA and sedentary behaviour of a sample of adolescents in the Czech Republic. Methods The study comprised two cross-sectional cohorts of adolescents ten years apart. The analysis compared data collected through a week-long monitoring of adolescents' PA in 1998-2000 and 2008-2010. Adolescents wore either Yamax SW-701 or Omron HJ-105 pedometer continuously for 7 days (at least 10 hours per day excluding sleeping, hygiene and bathing. They also recorded their number of steps per day, the type and duration of PA and sedentary behaviour (in minutes on record sheets. In total, 902 adolescents (410 boys; 492 girls aged 14-18 were eligible for analysis. Results Overweight and obesity in Czech adolescents participating in this study increased from 5.5% (older cohort, 1998-2000 to 10.4% (younger cohort, 2008-2010. There were no inter-cohort significant changes in the total amount of sedentary behaviour in boys. However in girls, on weekdays, there was a significant increase in the total duration of sedentary behaviour of the younger cohort (2008-2010 compared with the older one (1998-2000. Studying and screen time (television and computer were among the main sedentary behaviours in Czech adolescents. The types of sedentary behaviour also changed: watching TV (1998-2000 was replaced by time spent on computers (2008-2010. The Czech health-related criterion (achieving 11,000 steps per day decreased only in boys from 68% (1998-2000 to 55% (2008-2010. Across both genders, 55%-75% of Czech adolescents met the health-related criterion of recommended steps per day, however less participants in the younger cohort (2008-2010 met this criterion than in the older cohort

  12. DITTY - a computer program for calculating population dose integrated over ten thousand years

    International Nuclear Information System (INIS)

    Napier, B.A.; Peloquin, R.A.; Strenge, D.L.

    1986-03-01

    The computer program DITTY (Dose Integrated Over Ten Thousand Years) was developed to determine the collective dose from long term nuclear waste disposal sites resulting from the ground-water pathways. DITTY estimates the time integral of collective dose over a ten-thousand-year period for time-variant radionuclide releases to surface waters, wells, or the atmosphere. This document includes the following information on DITTY: a description of the mathematical models, program designs, data file requirements, input preparation, output interpretations, sample problems, and program-generated diagnostic messages

  13. Forest resources of southeast Alaska, 2000: results of a single-phase systematic sample.

    Science.gov (United States)

    Willem W.S. van Hees

    2003-01-01

    A baseline assessment of forest resources in southeast Alaska was made by using a single-phase, unstratified, systematic-grid sample, with ground plots established at each grid intersection. Ratio-of-means estimators were used to develop population estimates. Forests cover an estimated 48 percent of the 22.9-million-acre southeast Alaska inventory unit. Dominant forest...

  14. Powers of ten

    CERN Document Server

    1979-01-01

    Powers of Ten is a 1977 short documentary film written and directed by Charles Eames and his wife, Ray. The film depicts the relative scale of the Universe in factors of ten (see also logarithmic scale and order of magnitude). The idea for the film appears to have come from the 1957 book Cosmic View by Kees Boeke. The film begins with an aerial image of a man reclining on a blanket; the view is that of one meter across. The viewpoint, accompanied by expository voiceover, then slowly zooms out to a view ten meters across ( or 101 m in standard form), revealing that the man is picnicking in a park with a female companion. The zoom-out continues, to a view of 100 meters (102 m), then 1 kilometer (103 m), and so on, increasing the perspective—the picnic is revealed to be taking place near Soldier Field on Chicago's waterfront—and continuing to zoom out to a field of view of 1024 meters, or the size of the observable universe. The camera then zooms back in to the picnic, and then to views of negative pow...

  15. Sample loading for C-14 measurement in the simulated organic solvent waste from a CANDU Nuclear Power Plant

    International Nuclear Information System (INIS)

    Dianu, Magdalena; Podina, C.; Nita, Valentina

    2005-01-01

    Full text: Sample preparation is a critical step in obtaining accurate results in scintillation counting. Standard (22 ml) glass and plastic vials were used in these experiments. The preliminary research was conducted using glass vials to allow visual verification that a homogeneous solution is obtained at the desired cocktail/sample ratio. Then, the research was moved into plastic vials to reduce backgrounds and improve the counting rate. Samples were counted in a Model 2100 TR Packard TRI-CARB liquid scintillation analyzer. The paper mainly contains: - Composition and data about liquid scintillation cocktails used (tables); - Characterization of radioactive waste - organic solvent contaminated with C-14; - Sample loading (tables); - Efficiency vs Sample Loading - for each cocktail used. Organic solvent sample volumes were added to the vials in 0.5 ml increments from 1 ml to 2 ml. Then, the liquid scintillation cocktail was added so that the sample-cocktail volume was 20 ml. Each vial was shaken vigorously for several seconds after each addition to ensure homogeneity and count. Blank vials were prepared using C-14-free organic solvent samples in the same sample-cocktail proportions. After at least two hours, the samples and blank vials were counted for ten minutes, using a Packard counter. (authors)

  16. U.S. 15 Minute Precipitation Data

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — U.S. 15 Minute Precipitation Data is digital data set DSI-3260, archived at the National Climatic Data Center (NCDC). This is precipitation data. The primary source...

  17. Minutes of the fourth SALE program participants meeting

    Energy Technology Data Exchange (ETDEWEB)

    1981-10-01

    This report is a documentation of the presentations made to the Fourth Safeguards Analytical Laboratory Evaluation (S.A.L.E.) Program Participants Meeting at Argonne, Illinois, July 8-9, 1981. The meeting was sponsored by the US Department of Energy and was coordinated by the S.A.L.E. Program of the New Brunswick Laboratory. The objective of the meeting was to provide a forum through which administration of the Program and methods appropriate to the analysis of S.A.L.E. Program samples could be discussed. The Minutes of the Meeting is a collection of presentations by the speakers at the meeting and of the discussions following the presentations. The presentations are included as submitted by the speakers. The discussion sections were transcribed from tape recordings of the meeting and were edited to clarify and emphasize important comments. Seventeen papers have been abstracted and indexed.

  18. Minutes of the fourth SALE program participants meeting

    International Nuclear Information System (INIS)

    1981-10-01

    This report is a documentation of the presentations made to the Fourth Safeguards Analytical Laboratory Evaluation (S.A.L.E.) Program Participants Meeting at Argonne, Illinois, July 8-9, 1981. The meeting was sponsored by the US Department of Energy and was coordinated by the S.A.L.E. Program of the New Brunswick Laboratory. The objective of the meeting was to provide a forum through which administration of the Program and methods appropriate to the analysis of S.A.L.E. Program samples could be discussed. The Minutes of the Meeting is a collection of presentations by the speakers at the meeting and of the discussions following the presentations. The presentations are included as submitted by the speakers. The discussion sections were transcribed from tape recordings of the meeting and were edited to clarify and emphasize important comments. Seventeen papers have been abstracted and indexed

  19. Single injection 51Cr EDTA plasma clearance determination in children using capillary blood samples

    International Nuclear Information System (INIS)

    Broechner-Mortensen, J.; Christoffersen, J.

    1977-01-01

    The reliability of a determination of the total 51 Cr EDTA plasma clearance (e) (and with it the glomerular filtration rate), by a simplified single injection method (injected dose: 4.5 μCi per kg b.w.) using capillary blood samples (0.2 ml), was investigated in twenty children. Clearance values determined from capillary blood samples did not differ significantly from those measured simultaneously from venous blood samples, the mean ratio+-SD being 1.02+-0.06(n = 10). The reproducibility (total day-to-day variation) of E determined from capillary blood samples was 6.7% in children with decreased renal function (n = 3) and 6.9% in children with normal renal function (n = 7). The present data indicate that the use of capillary blood samples is an accurate and very precise approach for determination of E in children. (Auth.)

  20. Standard Specification for Sampling Single-Phase Geothermal Liquid or Steam for Purposes of Chemical Analysis

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1983-01-01

    1.1 This specification covers the basic requirements for equipment to be used for the collection of uncontaminated and representative samples from single-phase geothermal liquid or steam. Geopressured liquids are included. See Fig 1.

  1. Transcutaneous electrical nerve stimulation (TENS) reduces pain and postpones the need for pharmacological analgesia during labour: a randomised trial.

    Science.gov (United States)

    Santana, Licia Santos; Gallo, Rubneide Barreto Silva; Ferreira, Cristine Homsi Jorge; Duarte, Geraldo; Quintana, Silvana Maria; Marcolin, Alessandra Cristina

    2016-01-01

    In the active phase of the first stage of labour, does transcutaneous electrical nerve stimulation (TENS) relieve pain or change its location? Does TENS delay the request for neuraxial analgesia during labour? Does TENS produce any harmful effects in the mother or the foetus? Are women in labour satisfied with the care provided? Randomised trial with concealed allocation, assessor blinding for some outcomes, and intention-to-treat analysis. Forty-six low-risk, primigravida parturients with a gestational age > 37 weeks, cervical dilation of 4cm, and without the use of any medications from hospital admission until randomisation. The principal investigator applied TENS to the experimental group for 30minutes starting at the beginning of the active phase of labour. A second investigator assessed the outcomes in both the control and experimental groups. Both groups received routine perinatal care. The primary outcome was pain severity after the intervention period, which was assessed using the 100-mm visual analogue scale. Secondary outcomes included: pain location, duration of the active phase of labour, time to pharmacological labour analgesia, mode of birth, neonatal outcomes, and the participant's satisfaction with the care provided. After the intervention, a significant mean difference in change in pain of 15mm was observed favouring the experimental group (95% CI 2 to 27). The application of TENS did not alter the location or distribution of the pain. The mean time to pharmacological analgesia after the intervention was 5.0hours (95% CI 4.1 to 5.9) longer in the experimental group. The intervention did not significantly impact the other maternal and neonatal outcomes. Participants in both groups were satisfied with the care provided during labour. TENS produces a significant decrease in pain during labour and postpones the need for pharmacological analgesia for pain relief. NCT01600495. Copyright © 2015. Published by Elsevier B.V.

  2. Idaho National Laboratory 2013-2022 Ten-Year Site Plan

    Energy Technology Data Exchange (ETDEWEB)

    Calvin Ozaki; Sheryl L. Morton; Elizabeth A. Connell; William T. Buyers; Craig L. Jacobson; Charles T. Mullen; Christopher P. Ischay; Ernest L. Fossum; Robert D. Logan

    2011-06-01

    The Idaho National Laboratory (INL) Ten-Year Site Plan (TYSP) describes the strategy for accomplishing the long-term objective of transforming the laboratory to meet Department of Energy (DOE) national nuclear research and development (R&D) goals, as outlined in DOE strategic plans. The plan links R&D mission goals and INL core capabilities with infrastructure requirements (single- and multi-program), establishs the 10-year end-state vision for INL complexes, and identifies and prioritizes infrastructure needs and capability gaps. The TYSP serves as the basis for documenting and justifying infrastructure investments proposed as part of the FY 2013 budget formulation process.

  3. Attributes measurements by calorimetry in 15 to 30 minutes

    International Nuclear Information System (INIS)

    Fiarman, S.; Perry, R.B.

    1987-01-01

    An analysis of the early portion of the power-history data collected with both of the IAEA's air-cooled bulk calorimeters has demonstrated that such calorimeters can measure the power from preheated containers of plutonium oxide with an accuracy of 2 to 5% in 15 to 30 minutes. Material accountancy at plutonium facilities has a need for such a capability for measurement of Pu scrap. Also, the International Atomic Energy Agency (IAEA) could use just two calorimeters and a gamma-ray assay system for reliable variables and attributes measurements of plutonium mass during a two-day physical-inventory verification (PIV) at a mixed-oxide (MOX) fuel-fabrication facility. The assay results would be free of the concerns about sample moisture, impurities, and geometry that previously have limited the accuracy of assays based on neutron measurements

  4. Effect of feedback on delaying deterioration in quality of compressions during 2 minutes of continuous chest compressions

    DEFF Research Database (Denmark)

    Lyngeraa, Tobias S; Hjortrup, Peter Buhl; Wulff, Nille B

    2012-01-01

    delays deterioration of quality of compressions. METHODS: Participants attending a national one-day conference on cardiac arrest and CPR in Denmark were randomized to perform single-rescuer BLS with (n = 26) or without verbal and visual feedback (n = 28) on a manikin using a ZOLL AED plus. Data were...... analyzed using Rescuenet Code Review. Blinding of participants was not possible, but allocation concealment was performed. Primary outcome was the proportion of delivered compressions within target depth compared over a 2-minute period within the groups and between the groups. Secondary outcome...... was the proportion of delivered compressions within target rate compared over a 2-minute period within the groups and between the groups. Performance variables for 30-second intervals were analyzed and compared. RESULTS: 24 (92%) and 23 (82%) had CPR experience in the group with and without feedback respectively. 14...

  5. 3-minute Stephen Hawking. His life, theories and influence

    International Nuclear Information System (INIS)

    Parsons, Paul; Dixon, Gail

    2013-01-01

    3-minutes Stephen Hawking offers a compact introduction to life and work of this impressing scientist. This book is devided into three parts: Hawking's life, his theories, his influence. Each part offers fascinating reading material for one hour. The partial themes of this book are served up in practical 3-minute portions.

  6. A simple, one-tube assay for the simultaneous detection and diagnosis of ten Australian poultry Eimeria.

    Science.gov (United States)

    Godwin, Rosamond M; Morgan, Jess A T

    2014-02-01

    Coccidiosis is a costly worldwide enteric disease of chickens caused by parasites of the genus Eimeria. At present, there are seven described species that occur globally and a further three undescribed, operational taxonomic units (OTUs X, Y, and Z) that are known to infect chickens from Australia. Species of Eimeria have both overlapping morphology and pathology and frequently occur as mixed-species infections. This makes definitive diagnosis with currently available tests difficult and, to date, there is no test for the detection of the three OTUs. This paper describes the development of a PCR-based assay that is capable of detecting all ten species of Eimeria, including OTUs X, Y, and Z in field samples. The assay is based on a single set of generic primers that amplifies a single diagnostic fragment from the mitochondrial genome of each species. This one-tube assay is simple, low-cost, and has the capacity to be high throughput. It will therefore be of great benefit to the poultry industry for Eimeria detection and control, and the confirmation of identity and purity of vaccine strains. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Determination of burial dose in incompletely bleached fluvial samples using single grains of quartz

    DEFF Research Database (Denmark)

    Thomsen, Kristina Jørkov; Murray, A.S.; Bøtter-Jensen, Lars

    2007-01-01

    We determine the burial dose in three known-age incompletely bleached fluvial samples using single grains of quartz. Estimation of burial dose in incompletely bleached samples requires that the characteristics of the well-bleached part of the distribution are known in order to distinguish between...... well-bleached and poorly bleached grains. It is especially important to investigate if the uncertainties assigned to individual estimates of dose adequately describe the observed variability in well-bleached dose distributions. We investigate this by quantifying the overdispersion in laboratory-bleached...

  8. One-Minute Paper: A thinking centered assessment tool | Ashakiran ...

    African Journals Online (AJOL)

    A versatile assessment technique used in classroom for quick and simple feedback is 'One-Minute paper'. It provides real-time feedback from class and enables the teacher to find out if students have recognized the main points in a class session. The objectives of the study were to employ one-minute paper for ...

  9. [Six-minute walk test in children with neuromuscular disease.

    Science.gov (United States)

    Cruz-Anleu, Israel Didier; Baños-Mejía, Benjamín Omar; Galicia-Amor, Susana

    2013-01-01

    Background: neuromuscular diseases affect the motor unit. When they evolve, respiratory complications are common; the six-minute walk test plays an important role in the assessment of functional capacity. Methods: prospective, transversal, descriptive and observational study. We studied seven children with a variety of neuromuscular diseases and spontaneous ambulation. We tested their lung function, and administered a six-minute walk test and a test of respiratory muscle strength to these children. Results: the age was 9.8 ± 2.4 years. All patients were males. Forced vital capacity decreased in three patients (42.8 %), forced expiratory volume during the first second (2.04 ± 1.4 L) and peak expiratory flow (4.33 ± 3.3 L/s) were normal. The maximum strength of respiratory muscles was less than 60 % of predicted values. The distance covered in the six-minute walk test was lower when compared with healthy controls (29.9 %). Conclusions: the six-minute walk test can be a useful tool in early stages of this disease, since it is easy to perform and well tolerated by the patients.

  10. Smiles count but minutes matter: responses to classroom exercise breaks.

    Science.gov (United States)

    Howie, Erin K; Newman-Norlund, Roger D; Pate, Russell R

    2014-09-01

    To determine the subjective responses of teachers and students to classroom exercise breaks, and how responses varied by duration. This mixed-methods experimental study included focus groups with teachers (N = 8) and 4(th)- and 5(th)-grade students (N = 96). Students participated in 5-, 10-, and 20-minute exercise breaks and 10 minutes of sedentary activity. In an additional exploratory analysis, video-tapes of each condition were coded and compared for positive affect. Students and teachers discussed multiple benefits, but teachers discussed barriers to implementing regular breaks of 5-minutes or more. Students exhibited higher positive affect during each exercise condition. Classroom exercise breaks are an enjoyable way to increase physical activity, but additional support may be needed to encourage teachers to implement breaks of 5 minutes or longer.

  11. Laboratory sample turnaround times: do they cause delays in the ED?

    Science.gov (United States)

    Gill, Dipender; Galvin, Sean; Ponsford, Mark; Bruce, David; Reicher, John; Preston, Laura; Bernard, Stephani; Lafferty, Jessica; Robertson, Andrew; Rose-Morris, Anna; Stoneham, Simon; Rieu, Romelie; Pooley, Sophie; Weetch, Alison; McCann, Lloyd

    2012-02-01

    Blood tests are requested for approximately 50% of patients attending the emergency department (ED). The time taken to obtain the results is perceived as a common reason for delay. The objective of this study was therefore to investigate the turnaround time (TAT) for blood results and whether this affects patient length of stay (LOS) and to identify potential areas for improvement. A time-in-motion study was performed at the ED of the John Radcliffe Hospital (JRH), Oxford, UK. The duration of each of the stages leading up to receipt of 101 biochemistry and haematology results was recorded, along with the corresponding patient's LOS. The findings reveal that the mean time for haematology results to become available was 1 hour 6 minutes (95% CI: 29 minutes to 2 hours 13 minutes), while biochemistry samples took 1 hour 42 minutes (95% CI: 1 hour 1 minute to 4 hours 21 minutes), with some positive correlation noted with the patient LOS, but no significant variation between different days or shifts. With the fastest 10% of samples being reported within 35 minutes (haematology) and 1 hour 5 minutes (biochemistry) of request, our study showed that delays can be attributable to laboratory TAT. Given the limited ability to further improve laboratory processes, the solutions to improving TAT need to come from a collaborative and integrated approach that includes strategies before samples reach the laboratory and downstream review of results. © 2010 Blackwell Publishing Ltd.

  12. The Land-Use and Land-Cover Change Analysis in Beijing Huairou in Last Ten Years

    Science.gov (United States)

    Zhao, Q.; Liu, G.; Tu, J.; Wang, Z.

    2018-04-01

    With eCognition software, the sample-based object-oriented classification method is used. Remote sensing images in Huairou district of Beijing had been classified using remote sensing images of last ten years. According to the results of image processing, the land use types in Huairou district of Beijing were analyzed in the past ten years, and the changes of land use types in Huairou district were obtained, and the reasons for its occurrence were analyzed.

  13. USGS 1:12000 (Quarter 7 1/2 Minute) Quadrangle Index

    Data.gov (United States)

    Minnesota Department of Natural Resources — This is a mathematically generated grid in which each polygon represents one quarter of a standard USGS 7 1/2 minute quadrangle. The result is a 3 3/4 minute...

  14. Ten Lessons from Ten Years PPP Experience in Belgium

    NARCIS (Netherlands)

    Willems, T.; Verhoest, K.; Voets, J.; Coppens, T.; van Dooren, W.; van den Hurk, M.

    2017-01-01

    In 2004 Flanders, the northern region of Belgium launched a range of large public–private partnership (PPP) projects for a total value of 6 billion euros. Ten years later, PPP has become a well-embedded procurement method for long-term public infrastructure projects. This article makes a critical

  15. The Influence of Instructional Minutes on Grade 11 Language Arts and Mathematics High School Proficiency Assessment Performance

    Science.gov (United States)

    Welcome, Simone E.

    2017-01-01

    The purpose for this cross-sectional, non-experimental explanatory quantitative research study was to explain the amount of variance in the High School Proficiency Assessment-11 Language Arts and Mathematics scores accounted for by the amount of instructional minutes at high schools in New Jersey. A proportional, stratified random sample which…

  16. Comparison of five-minute radon-daughter measurements with long-term radon and radon-daughter concentrations

    International Nuclear Information System (INIS)

    Young, J.A.; Jackson, P.O.; Thomas, V.W.

    1983-01-01

    Five-minute air filter radon daughter measurements were made in 84 buildings in Edgemont, South Dakota, in which annual average radon daughter concentrations have been determined from six 100-hour Radon Progeny Integrating Sampling Unit (RPISU) measurements. Averaging radon concentrations were also determined in 50 of these buildings using Terradex Track Etch detectors. The standard deviation of the difference between the (natural) logarithms of the RPISU annual averages and the logarithms of the air filter measurements (SD-ln) was found to be 0.52. This SD-ln is considerably smaller than the SD-ln of 0.71 between the RPISU annual averages and the air filter measurements reported by ALARA at Grand Junction, Colorado; presumably because a considerable number of air filter measurements in Edgemont were disregarded because of short turnover times or high wind speeds. Using the SD-ln of 0.52 it can be calculated that there would only be a 5% probability in Edgemont that the RPISU annual average would be greater than 0.015 WL if the five-minute measurement were equal to 0.010 WL. This indicates that the procedure used in Edgemont of clearing buildings from remedial action if the five-minute measurement were less than 0.010 WL was reasonable. There was about a 28% probability that the RPISU annual average would be less than 0.015 WL if the five-minute measurement were 0.033 WL, indicating that the procedure of performing an engineering assessment if the average of two five-minute measurements was greater than 0.033 WL was also reasonable. Comparison indicates that the average of two RPISU measurements taken six months apart would provide a dependable estimate of the annual average

  17. Exploring Market State and Stock Interactions on the Minute Timescale.

    Directory of Open Access Journals (Sweden)

    Lei Tan

    Full Text Available A stock market is a non-stationary complex system. The stock interactions are important for understanding the state of the market. However, our knowledge on the stock interactions on the minute timescale is limited. Here we apply the random matrix theory and methods in complex networks to study the stock interactions and sector interactions. Further, we construct a new kind of cross-correlation matrix to investigate the correlation between the stock interactions at different minutes within one trading day. Based on 50 million minute-to-minute price data in the Shanghai stock market, we discover that the market states in the morning and afternoon are significantly different. The differences mainly exist in three aspects, i.e. the co-movement of stock prices, interactions of sectors and correlation between the stock interactions at different minutes. In the afternoon, the component stocks of sectors are more robust and the structure of sectors is firmer. Therefore, the market state in the afternoon is more stable. Furthermore, we reveal that the information of the sector interactions can indicate the financial crisis in the market, and the indicator based on the empirical data in the afternoon is more effective.

  18. Exploring Market State and Stock Interactions on the Minute Timescale.

    Science.gov (United States)

    Tan, Lei; Chen, Jun-Jie; Zheng, Bo; Ouyang, Fang-Yan

    2016-01-01

    A stock market is a non-stationary complex system. The stock interactions are important for understanding the state of the market. However, our knowledge on the stock interactions on the minute timescale is limited. Here we apply the random matrix theory and methods in complex networks to study the stock interactions and sector interactions. Further, we construct a new kind of cross-correlation matrix to investigate the correlation between the stock interactions at different minutes within one trading day. Based on 50 million minute-to-minute price data in the Shanghai stock market, we discover that the market states in the morning and afternoon are significantly different. The differences mainly exist in three aspects, i.e. the co-movement of stock prices, interactions of sectors and correlation between the stock interactions at different minutes. In the afternoon, the component stocks of sectors are more robust and the structure of sectors is firmer. Therefore, the market state in the afternoon is more stable. Furthermore, we reveal that the information of the sector interactions can indicate the financial crisis in the market, and the indicator based on the empirical data in the afternoon is more effective.

  19. DSCOVR Magnetometer Level 2 One Minute Averages

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Interplanetary magnetic field observations collected from magnetometer on DSCOVR satellite - 1-minute average of Level 1 data

  20. Length-dependent optical properties of single-walled carbon nanotube samples

    International Nuclear Information System (INIS)

    Naumov, Anton V.; Tsyboulski, Dmitri A.; Bachilo, Sergei M.; Weisman, R. Bruce

    2013-01-01

    Highlights: ► Length-independent absorption per atom in single-walled carbon nanotubes. ► Reduced fluorescence quantum yield for short nanotubes. ► Exciton quenching at nanotube ends, sidewall defects probably limits quantum yield. - Abstract: Contradictory findings have been reported on the length dependence of optical absorption cross sections and fluorescence quantum yields in single-walled carbon nanotubes (SWCNTs). To clarify these points, studies have been made on bulk SWCNT dispersions subjected to length fractionation by electrophoretic separation or by ultrasonication-induced scission. Fractions ranged from ca. 120 to 760 nm in mean length. Samples prepared by shear-assisted dispersion were subsequently shortened by ultrasonic processing. After accounting for processing-induced changes in the surfactant absorption background, SWCNT absorption was found constant within ±11% as average nanotube length changed by a factor of 3.8. This indicates that the absorption cross-section per carbon atom is not length dependent. By contrast, in length fractions prepared by both methods, the bulk fluorescence efficiency or average quantum yield increased with SWCNT average length and approached an apparent asymptotic limit near 1 μm. This result is interpreted as reflecting the combined contributions of exciton quenching by sidewall defects and by the ends of shorter nanotubes

  1. THE LAND-USE AND LAND-COVER CHANGE ANALYSIS IN BEIJING HUAIROU IN LAST TEN YEARS

    Directory of Open Access Journals (Sweden)

    Q. Zhao

    2018-04-01

    Full Text Available With eCognition software, the sample-based object-oriented classification method is used. Remote sensing images in Huairou district of Beijing had been classified using remote sensing images of last ten years. According to the results of image processing, the land use types in Huairou district of Beijing were analyzed in the past ten years, and the changes of land use types in Huairou district were obtained, and the reasons for its occurrence were analyzed.

  2. Transcutaneous electrical nerve stimulation and transcutaneous spinal electroanalgesia: a preliminary efficacy and mechanisms-based investigation.

    Science.gov (United States)

    Palmer, Shea; Cramp, Fiona; Propert, Kate; Godfrey, Helen

    2009-09-01

    To determine the effects of transcutaneous electrical nerve stimulation (TENS) and transcutaneous spinal electroanalgesia (TSE) on mechanical pain threshold (MPT) and vibration threshold (VT). A prospective, single-blind, randomised, placebo-controlled trial. Laboratory based. Thirty-four healthy volunteers (12 men and 22 women; mean age+/-standard deviation 30+/-8 years). Exclusion criteria were conditions affecting upper limb sensation and contraindications to electrical stimulation. Participants were allocated at random to receive TENS (n=8), TSE (n=8), placebo (n=9) or control (n=9). Electrical stimulation was applied for 30 minutes (from time 18 minutes to 48 minutes) via electrodes (5 cmx5 cm) placed centrally above and below the space between the C6 and C7 spinous processes, with 5 cm between electrodes. MPT (using an algometer) and VT (using a vibrameter) were recorded on seven occasions from the first dorsal interosseous muscle of the right hand - at baseline (0 minutes) and then at 10-minute intervals until the end of the 60-minute testing period. There were no statistically significant group differences in MPT (all p>0.05). Significant group differences in VT were found at 20, 30 and 40 minutes (all ptests showed that the TENS group had significantly greater VT than both the placebo [median difference 0.30 microm, 95% confidence interval (CI) -0.05 to 0.66] and control (0.51 microm, 95% CI 0.05 to 0.97) groups at 20 minutes, and significantly greater VT than the control group (0.69 microm, 95% CI 0.20 to 1.17) at 30 minutes (all p<0.008). Electrical stimulation did not alter MPT. The increase in VT during TENS may be due to distraction or antidromic block of large-diameter nerve fibres. TSE failed to alter either outcome measure significantly.

  3. 2-minute Gridded Global Relief Data (ETOPO2) v2

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Two-minute gridded global relief for both ocean and land areas are available in the ETOPO2v2 (2006) database. ETOPO2v2 replaced ETOPO2 (2001). The historic 2-minute...

  4. Efficacy of transcutaneous electrical nerve stimulation (tens) for chronic low-back pain in a multiple sclerosis population: a randomized, placebo-controlled clinical trial.

    Science.gov (United States)

    Warke, Kim; Al-Smadi, Jamal; Baxter, David; Walsh, Deirdre M; Lowe-Strong, Andrea S

    2006-01-01

    This study was designed to investigate the hypoalgesic effects of self-applied transcutaneous electrical nerve stimulation (TENS) on chronic low-back pain (LBP) in a multiple sclerosis (MS) population. Ninety participants with probable or definite MS (aged 21 to 78 y) presenting with chronic LBP were recruited and randomized into 3 groups (n=30 per group): (1) low-frequency TENS group (4 Hz, 200 micros); (2) high-frequency TENS group (110 Hz, 200 micros); and (3) placebo TENS. Participants self-applied TENS for 45 minutes, a minimum of twice daily, for 6 weeks. Outcome measures were recorded at weeks 1, 6, 10, and 32. Primary outcome measures included: Visual Analog Scale for average LBP and the McGill Pain Questionnaire. Secondary outcome measures included: Visual Analog Scale for worst and weekly LBP, back and leg spasm; Roland Morris Disability Questionnaire; Barthel Index; Rivermead Mobility Index; Multiple Sclerosis Quality of Life-54 Instrument, and a daily logbook. Data were analyzed blind using parametric and nonparametric tests, as appropriate. Results indicated a statistically significant interactive effect between groups for average LBP (P=0.008); 1-way analysis of covariance did not show any significant effects at any time point once a Bonferonni correction was applied (P>0.05). However, clinically important differences were observed in some of the outcome measures in both active treatment groups during the treatment and follow-up periods. Although not statistically significant, the observed effects may have implications for the clinical prescription and the use of TENS within this population.

  5. Alterations in the morphology of skeletal myofibres after 90 minutes ...

    African Journals Online (AJOL)

    Alterations in the morphology of skeletal myofibres after 90 minutes of ischaemia and '- 3 hours of reperfusion. M.A. Gregory, M. Mars. Abstract. Morphometric, light and electron microscopic methods were employed to determine whether skeletal myofibres were damaged by 90 minutes of tourniquet-mediated ischaemia.

  6. Simultaneous isolation of mRNA and native protein from minute samples of cells

    DEFF Research Database (Denmark)

    Petersen, Tonny Studsgaard; Andersen, Claus Yding

    2014-01-01

    Precious biological samples often lack a sufficient number of cells for multiple procedures, such as extraction of mRNA while maintaining protein in a non-denatured state suitable for subsequent characterization. Here we present a new method for the simultaneous purification of mRNA and native...... in their native state for traditional protein assays. We validated the procedure using neonatal rat ovaries and small numbers of human granulosa cells, demonstrating the extraction of mRNA suitable for gene expression analysis with simultaneous isolation of native proteins suitable for downstream characterization...... proteins from samples containing small numbers of cells. Our approach utilizes oligodeoxythymidylate [oligo(dT)25]-coated paramagnetic beads in an optimized reaction buffer to isolate mRNA comparable in quantity and quality to mRNA isolated with existing methods, while maintaining the proteins...

  7. Three minute versus six minute adenosine infusion in myocardial perfusion scintigraphy

    International Nuclear Information System (INIS)

    Gopinath, G.; Naojee, S.A.; Croasdale, J.; Johnson, G.; Hilson, A.J.W.; Buscombe, J.R.

    2003-01-01

    Pharmacological stress imaging techniques are used widely in clinical nuclear cardiology for evaluation of ischemic heart disease. Adenosine is often used but is expensive and causes significant side effects .The aim of this retrospective review was to study the tolerance and efficacy, of adenosine infusion of a 3 minute (min) versus the conventional 6 min stress protocol and to assess the cost efficiency of the 3 min protocol. Three hundred thirty one patients had myocardial scintigraphy using adenosine as a stressing agent. Blood pressure, heart rate and ECG were recorded at baseline and during the test. Symptoms (flushing, headache, chest pain, dyspnoea, neck pain) were recorded throughout the adenosine infusion. All the patients had had either 6 min or 3 min adenosine infusion at 140 mg/kg per minute. 169 of them had side effects. Flushing (32% at 3 min vs 50 % at 6 min, p<0.05), headache (11.5% at 3 min vs 7 % at 6 min p-not significant-ns), chest pain (8% at 3 min vs 13 % at 6 min, ns), dyspnoea (7% at 3 min vs %10 at 6 min, ns), ECG changes (10% at 3 min vs 28% at 6 min, p<0.05), neck pain (4.5% at 3 min vs 9% at 6 min, ns), abdominal discomfort (3% at 3 min vs 3% at 6 min, ns) and fall in blood pressure (6% at 3 min vs 8.5% at 6 min, ns). The change in heart rate was not significant with either protocol. The 6 min and 3 min infusions of adenosine had similar accuracy (73% vs 70%) for the detection of coronary artery disease. The patients tolerated the 3 min protocol better with only 40% of the patients having minimal side effects compared with 60% for the 6 mon protocol. The 3 min protocol is also cost effective as it uses less adenosine and therefore reduces total costs by 40 US$ per patient. (author)

  8. Ovarian dysgenesis in an alpaca with a minute chromosome 36.

    Science.gov (United States)

    Fellows, Elizabeth; Kutzler, Michelle; Avila, Felipe; Das, Pranab J; Raudsepp, Terje

    2014-01-01

    A 4-year-old female alpaca (Lama pacos [LPA]) was presented to the Oregon State Veterinary Teaching Hospital for failure to display receptive behavior to males. Although no abnormalities were found on physical examination, transrectal ultrasonographic examination of the reproductive tract revealed uterine hypoplasia and ovarian dysgenesis. Cytogenetic analysis demonstrated a normal female 74,XX karyotype with 1 exceptionally small (minute) homologue of autosome LPA36. Chromosome analysis by Giemsa staining and DAPI- and C-banding revealed that the minute LPA36 was submetacentric, AT-rich, and largely heterochromatic. Because of the small size and lack of molecular markers, it was not possible to identify the origin of the minute. There is a need to improve molecular cytogenetic tools to further study the phenomenon of this minute chromosome and its relation to female reproduction in alpacas and llamas. © The American Genetic Association. 2012. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  9. Characterizing full matrix constants of piezoelectric single crystals with strong anisotropy using two samples

    Science.gov (United States)

    Tang, Liguo; Zhang, Yang; Cao, Wenwu

    2016-10-01

    Although the self-consistency of the full matrix material constants of a piezoelectric sample obtained by the resonant ultrasonic spectroscopy technique can be guaranteed because all constants come from the same sample, it is a great challenge to determine the constants of a piezoelectric sample with strong anisotropy because it might not be possible to identify enough resonance modes from the resonance spectrum. To overcome this difficulty, we developed a strategy to use two samples of similar geometries to increase the number of easy identifiable modes. Unlike the IEEE resonance methods, sample-to-sample variation here is negligible because the two samples have almost the same dimensions, cut from the same specimen and poled under the same conditions. Using this method, we have measured the full matrix constants of a [011]c poled 0.71Pb(Mg1/3Nb2/3)O3-0.29PbTiO3 single crystal, which has 17 independent constants. The self-consistency of the obtained results is checked by comparing the calculated elastic stiffness constants c33 D , c44 D , and c55 D with those directly measured ones using the ultrasonic pulse-echo method.

  10. Warm-up Optimizes Postural Control but Requires Some Minutes of Recovery.

    Science.gov (United States)

    Paillard, Thierry; Kadri, Mohamed Abdelhafid; Nouar, Merbouha Boulahbel; Noé, Frederic

    2018-05-02

    Paillard, T, Kadri, MA, Nouar, MB, and Noé, F. Warm-up optimizes postural control but requires some minutes of recovery. J Strength Cond Res XX(X): 000-000, 2018-The aim was to compare monopedal postural control between the dominant leg (D-Leg) and the nondominant leg (ND-Leg) in pre- and post-warm-up conditions. Thirty healthy male sports science students were evaluated before and after a warm-up exercise (12 minutes of pedaling with an incremental effort on a cycle ergometer with a controlled workload). Monopodal postural control was assessed for the D- and ND-Legs before and immediately, 2, 5, 10, and 15 minutes after the warm-up exercise, using a force platform and calculating the displacement velocity of the center of foot pressure on the mediolateral (COPML velocity) and anteroposterior (COPAP velocity) axes. No significant difference was observed between the D-Leg and ND-Leg for both COPML and COPAP velocity in all the periods. In comparison with pre-warm-up, COPML decreased after 15-minute and 10-minute recovery periods for the D-Leg and the ND-Leg, respectively (p warm-up optimized monopedal postural control but did not make it possible to distinguish a difference between the D-Leg and the ND-Leg. Some minutes of recovery are required between the end of the whole-body warm-up exercise and the beginning of the postural test to optimize postural control. The optimal duration of recovery turns out to be about 10-15 minutes.

  11. Estimation of technetium 99m mercaptoacetyltriglycine plasma clearance by use of one single plasma sample

    International Nuclear Information System (INIS)

    Mueller-Suur, R.; Magnusson, G.; Karolinska Inst., Stockholm; Bois-Svensson, I.; Jansson, B.

    1991-01-01

    Recent studies have shown that technetium 99m mercaptoacetyltriglycine (MAG-3) is a suitable replacement for iodine 131 or 123 hippurate in gamma-camera renography. Also, the determination of its clearance is of value, since it correlates well with that of hippurate and thus may be an indirect measure of renal plasma flow. In order to simplify the clearance method we developed formulas for the estimation of plasma clearance of MAG-3 based on a single plasma sample and compared them with the multiple sample method based on 7 plasma samples. The correlation to effective renal plasma flow (ERPF) (according to Tauxe's method, using iodine 123 hippurate), which ranged from 75 to 654 ml/min per 1.73 m 2 , was determined in these patients. Using the developed regression equations the error of estimate for the simplified clearance method was acceptably low (18-14 ml/min), when the single plasma sample was taken 44-64 min post-injection. Formulas for different sampling times at 44, 48, 52, 56, 60 and 64 min are given, and we recommend 60 min as optimal, with an error of estimate of 15.5 ml/min. The correlation between the MAG-3 clearances and ERPF was high (r=0.90). Since normal values for MAG-3 clearance are not yet available, transformation to estimated ERPF values by the regression equation (ERPF=1.86xC MAG-3 +4.6) could be of clinical value in order to compare it with the normal values for ERPF given in the literature. (orig.)

  12. Multiple single-element transducer photoacoustic computed tomography system

    Science.gov (United States)

    Kalva, Sandeep Kumar; Hui, Zhe Zhi; Pramanik, Manojit

    2018-02-01

    Light absorption by the chromophores (hemoglobin, melanin, water etc.) present in any biological tissue results in local temperature rise. This rise in temperature results in generation of pressure waves due to the thermoelastic expansion of the tissue. In a circular scanning photoacoustic computed tomography (PACT) system, these pressure waves can be detected using a single-element ultrasound transducer (SUST) (while rotating in full 360° around the sample) or using a circular array transducer. SUST takes several minutes to acquire the PA data around the sample whereas the circular array transducer takes only a fraction of seconds. Hence, for real time imaging circular array transducers are preferred. However, these circular array transducers are custom made, expensive and not easily available in the market whereas SUSTs are cheap and readily available in the market. Using SUST for PACT systems is still cost effective. In order to reduce the scanning time to few seconds instead of using single SUST (rotating 360° ), multiple SUSTs can be used at the same time to acquire the PA data. This will reduce the scanning time by two-fold in case of two SUSTs (rotating 180° ) or by four-fold and eight-fold in case of four SUSTs (rotating 90° ) and eight SUSTs (rotating 45° ) respectively. Here we show that with multiple SUSTs, similar PA images (numerical and experimental phantom data) can be obtained as that of PA images obtained using single SUST.

  13. Coronary angiography in Qatar: the first ten years.

    Science.gov (United States)

    Chaikhouni, A; Gehani, A A; Horak, J; Hajar, H A

    1998-08-01

    Cardiac catheterization in Qatar was initiated in July 1982. In ten years, a total of 3900 procedures were performed at Hamad General Hospital. Computerized data registry has been maintained since 1982. Isolated coronary angiography was done in 2911 patients; of these, 2635 (90.5%) were men, and 276 (9.5%) were women, the average age of the patients was 47+/-9.2 years (range, twenty-five to eighty-eight). Patients' nationality was Qatari in 492 (17%), and other Arabs in 610 (21%), and 1512 (52%) were from the Asian subcontinent. Myocardial infarction was the most common indication (43%). Single-vessel disease was found in 638 (22%), two-vessel disease in 630 (22%), three-vessel disease in 950 (33%), and nonsignificant coronary artery disease in 693 (24%) patients. Morbidity related to the coronary angiography was reported in 147 (5%) patients, but there was no mortality related to the procedure. In 822 (28%) patients, the age was forty years or younger. The angiographic findings of these younger patients were compared with those of the older ones. Younger patients were usually men of Asian subcontinental origin with a recent myocardial infarction (MI). Often, they had normal coronary arteries or single-vessel disease. Patients of Asian subcontinent origin were usually young male patients with a recent MI, who receive streptokinase, and have single-vessel disease.

  14. 5 experiments in 5 minutes

    Science.gov (United States)

    Hut, Rolf

    2015-04-01

    Show, don't tell. When kids ask about your research, show, don't tell. We, the ambassadors of science, shouldn't be boring our nieces and nephews at family dinners with parameter distributions, we should make them excited about science. Getting people excited: show, don't tell. In 5 minutes, I will perform 5 experiments that anyone can do using everyday household items to get kids interested in science. Bring safety glasses.

  15. Effects of laryngeal manual therapy (LMT) and transcutaneous electrical nerve stimulation (TENS) in vocal folds diadochokinesis of dysphonic women: a randomized clinical trial.

    Science.gov (United States)

    Siqueira, Larissa Thaís Donalonso; Silverio, Kelly Cristina Alves; Brasolotto, Alcione Ghedini; Guirro, Rinaldo Roberto de Jesus; Carneiro, Christiano Giácomo; Behlau, Mara

    2017-05-15

    To verify and compare the effect of transcutaneous electrical nerve stimulation (TENS) and laryngeal manual therapy (LMT) on laryngeal diadochokinesis (DDK) of dysphonic women. Twenty women with bilateral vocal nodules participated and were equally divided into: LMT Group - LMT application; TENS Group - TENS application; both groups received 12 sessions of treatment, twice a week, with a duration of 20 minutes each, applied by the same therapist. The women were evaluated as to laryngeal DDK at three moments: diagnostic, pre-treatment, and post-treatment, which produced three groups of measurements. The DDK recording was performed with intersected repetition of vowels /a/ and / i/. The analysis of vowels was performed by the program Motor Speech Profile Advanced (MSP)-KayPentax. The DDK parameters of the three evaluations were compared by means of the paired t-test (p≤0.05). The measurements of laryngeal DDK parameters were similar in the phase without treatment, indicating no individual variability over time. There was no change with respect to the speed of DDK after intervention, but after LMT, DDK of the vowel /i/ was more stable in terms of the duration of the emissions and intensity of emissions repeated. These results show improved coordination of vocal folds movement during phonation. There were no changes in the DDK parameters following TENS. LMT provides greater regularity of movement during laryngeal diadochokinesis in dysphonic women, which extends knowledge on the effect of rebalancing the larynx muscles during phonation, although TENS does not impact laryngeal diadochokinesis.

  16. Deriving muscle fiber diameter from recorded single fiber potential.

    Science.gov (United States)

    Zalewska, Ewa

    2017-12-01

    The aim of the study was to estimate muscle fiber diameters through analysis of single muscle fiber potentials (SFPs) recorded in the frontalis muscle of a healthy subject. Our previously developed analytical and graphic method to derive fiber diameter from the analysis of the negative peak duration and the amplitude of SFP, was applied to a sample of ten SFPs recorded in vivo. Muscle fiber diameters derived from the simulation method for the sample of frontalis muscle SFPs are consistent with anatomical data for this muscle. The results confirm the utility of proposed simulation method. Outlying data could be considered as the result of a contribution of other fibers to the potential recorded using an SFEMG electrode. Our graphic tool provides a rapid estimation of muscle fiber diameter. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  17. CSEWG 2017 Minutes

    Energy Technology Data Exchange (ETDEWEB)

    Brown, D. [Brookhaven National Lab. (BNL), Upton, NY (United States); Sonzogni, A. [Brookhaven National Lab. (BNL), Upton, NY (United States); Chadwick, M. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Trkov, Andrej [Intl Atomic Energy Agency (IAEA), Vienna (Austria); Dunn, M. [SprectraTech, Oak Ridge, TN (United States); Danon, Y. [Rensselaer Polytechnic Inst., Troy, NY (United States); Neudecker, D. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-11-28

    These are the minutes of the 2017 Cross Section Evaluation Working Group (CSEWG). This meeting corresponds to the 50±1th anniversary of CSEWG. The uncertainty on the anniversary reflects the fact that CSEWG was formed in 1966 yet the first ENDF library was published in 1968. Despite the uncertainty on the date of the anniversary, this meeting is an especially auspicious one: this is the last meeting before the release of ENDF/B-VIII.0. This meeting is devoted both to closing out the last open issues before releasing the library and to looking toward the future. The careful reader should note that there are no closing statements in this meeting. This is in a way symbolic of the fact that since ENDF/B is always improving, our work here will never truly be done.

  18. A 30-Minute, but Not a 10-Minute Nighttime Nap is Associated with Sleep Inertia

    Science.gov (United States)

    Hilditch, Cassie J.; Centofanti, Stephanie A.; Dorrian, Jillian; Banks, Siobhan

    2016-01-01

    Study Objectives: To assess sleep inertia following 10-min and 30-min naps during a simulated night shift. Methods: Thirty-one healthy adults (aged 21–35 y; 18 females) participated in a 3-day laboratory study that included one baseline (BL) sleep (22:00–07:00) and one experimental night involving randomization to either: total sleep deprivation (NO-NAP), a 10-min nap (10-NAP) or a 30-min nap (30-NAP). Nap opportunities ended at 04:00. A 3-min psychomotor vigilance task (PVT-B), digit-symbol substitution task (DSST), fatigue scale, sleepiness scale, and self-rated performance scale were undertaken pre-nap (03:00) and at 2, 17, 32, and 47 min post-nap. Results: The 30-NAP (14.7 ± 5.7 min) had more slow wave sleep than the 10-NAP (0.8 ± 1.5 min; P inertia and helped to mitigate short-term performance impairment during a simulated night shift. Self-rated performance did not reflect objective performance following a nap. Citation: Hilditch CJ, Centofanti SA, Dorrian J, Banks S. A 30-minute, but not a 10-minute nighttime nap is associated with sleep inertia. SLEEP 2016;39(3):675–685. PMID:26715234

  19. Public sector district health system: Is seven to ten minutes enough ...

    African Journals Online (AJOL)

    The development of a municipality based district health system has created an opportunity to practice family medicine in Mitchells Plain, but lack of clinical time to practice family medicine in the current setting raises questions about the quality and efficiency of primary health care in the municipality based district based ...

  20. The Effects of Noncontingent Access to Single-versus Multiple-Stimulus Sets on Self-Injurious Behavior.

    Science.gov (United States)

    DeLeon, Iser G.; Anders, Bonita M.; Rodriguez-Catter, Vanessa; Neidert, Pamela L.

    2000-01-01

    The automatically reinforced self-injury of a girl (age 11) with autism was treated by providing noncontingent access to a single set of preferred toys during 30-minute sessions. Rotating toy sets after 10 minutes or providing access to multiple toy sets resulted in reductions that lasted the entire 30 minutes. (Contains four references.)…

  1. North Star Ambulatory Assessment, 6-minute walk test and timed items in ambulant boys with Duchenne muscular dystrophy.

    Science.gov (United States)

    Mazzone, Elena; Martinelli, Diego; Berardinelli, Angela; Messina, Sonia; D'Amico, Adele; Vasco, Gessica; Main, Marion; Doglio, Luca; Politano, Luisa; Cavallaro, Filippo; Frosini, Silvia; Bello, Luca; Carlesi, Adelina; Bonetti, Anna Maria; Zucchini, Elisabetta; De Sanctis, Roberto; Scutifero, Marianna; Bianco, Flaviana; Rossi, Francesca; Motta, Maria Chiara; Sacco, Annalisa; Donati, Maria Alice; Mongini, Tiziana; Pini, Antonella; Battini, Roberta; Pegoraro, Elena; Pane, Marika; Pasquini, Elisabetta; Bruno, Claudio; Vita, Giuseppe; de Waure, Chiara; Bertini, Enrico; Mercuri, Eugenio

    2010-11-01

    The North Star Ambulatory Assessment is a functional scale specifically designed for ambulant boys affected by Duchenne muscular dystrophy (DMD). Recently the 6-minute walk test has also been used as an outcome measure in trials in DMD. The aim of our study was to assess a large cohort of ambulant boys affected by DMD using both North Star Assessment and 6-minute walk test. More specifically, we wished to establish the spectrum of findings for each measure and their correlation. This is a prospective multicentric study involving 10 centers. The cohort included 112 ambulant DMD boys of age ranging between 4.10 and 17 years (mean 8.18±2.3 DS). Ninety-one of the 112 were on steroids: 37/91 on intermittent and 54/91 on daily regimen. The scores on the North Star assessment ranged from 6/34 to 34/34. The distance on the 6-minute walk test ranged from 127 to 560.6 m. The time to walk 10 m was between 3 and 15 s. The time to rise from the floor ranged from 1 to 27.5 s. Some patients were unable to rise from the floor. As expected the results changed with age and were overall better in children treated with daily steroids. The North Star assessment had a moderate to good correlation with 6-minute walk test and with timed rising from floor but less with 10 m timed walk/run test. The 6-minute walk test in contrast had better correlation with 10 m timed walk/run test than with timed rising from floor. These findings suggest that a combination of these outcome measures can be effectively used in ambulant DMD boys and will provide information on different aspects of motor function, that may not be captured using a single measure. Copyright © 2010. Published by Elsevier B.V.

  2. DEVELOPMENT OF SOME OF STUDENTS` MOTORIC ABILITIES AFTER TEN-DAY-SKIING COURSE

    Directory of Open Access Journals (Sweden)

    Ljubiša Lilić

    2007-05-01

    Full Text Available Considering the fact that one of the most fundamental tasks of training is developing motoric dimensions of sportsmen, the common goal of this work was to achieve relevant knowledge on the infl uence of ten-day-skiing course on students`* development and to establish their level. The special aim of this work was diagnosing the amount of some of the students` motoric abilities. According to the subjects, problems and goal of the research, there was a hypothesis put: motoric and morphological dimensions of students are coherent with their chrono logical growth and development ten-day-skiing course has signifi cant infl uence on developing some of the students` motoric abilities Besides remaining, the choice of examined samples was put under limits of organizational capacities for realizing researching procedure.It was necessary to insure required devices and standardized conditions under which planned research was supposed to be realized. The sample is taken from students` population implied in regular skiing course. Examined sample consists of thirty male students, each of which is twenty years old. Because of technical and organizational reasons it was not possible to diagnose the whole motoric range of tested students. Due to that a specifi c selection of tests was done and only six variables (that reliably predict levels of motoric abilities on which the training affects were taken: foot tapping, medicine ball throwing, pull-ups with undertaking, trunk lifting in 60 seconds and deep forward band. The level of students` motoric abilities after ten-day-skiing course is on a higher level then initial measuring, and we can certainly claim that it is the result of programmed training process during skiing course. According to the data gained from control and fi nal measuring you can fi nd out the effects of applied resources towards initial measuring.

  3. The Supersymmetric Top-Ten Lists

    OpenAIRE

    Haber, Howard E.

    1993-01-01

    Ten reasons are given why supersymmetry is the leading candidate for physics beyond the Standard Model. Ultimately, the experimental discovery of supersymmetric particles at future colliders will determine whether supersymmetry is relevant for TeV scale physics. The grand hope of supersymmetry enthusiasts is to connect TeV scale supersymmetry with Planck scale physics. The ten most pressing theoretical problems standing in the way of this goal are briefly described.

  4. 60 minutes/our reply

    International Nuclear Information System (INIS)

    Deakins, H.L.

    1981-01-01

    The prestigious CBS show 60 Minutes visited Illinois Power Company, an investor owned utility company building its first nuclear power plant, to do a story on the economics of nuclear construction. The company opened its doors to the show's producer and was astonished at the program that resulted. Illinois Power had filmed everything CBS filmed and subsequently prepared its own rebutal video tape showing unedited portions of interviews and factual information furnished CBS which they never used in the broadcast. The rebuttal tape has been distributed world wide and received coverage in leading newspapers and magazines. It has also been installed as a class study in major journalism and business schools

  5. ALGORITHMS FOR TETRAHEDRAL NETWORK (TEN) GENERATION

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    The Tetrahedral Network(TEN) is a powerful 3-D vector structure in GIS, which has a lot of advantages such as simple structure, fast topological relation processing and rapid visualization. The difficulty of TEN application is automatic creating data structure. Al though a raster algorithm has been introduced by some authors, the problems in accuracy, memory requirement, speed and integrity are still existent. In this paper, the raster algorithm is completed and a vector algorithm is presented after a 3-D data model and structure of TEN have been introducted. Finally, experiment, conclusion and future work are discussed.

  6. Multielemental determination in ten maize plant fragment using neutron activation analysis

    International Nuclear Information System (INIS)

    Spiridon, S.

    1993-01-01

    An instrumental activation technique has been developed for simultaneous analysis in dry ash maize plant samples of 18 elements: Al, Au, Ca, Ce, Co, Cr, Cs, Eu, Fe, La, Lu, K, Mg, Mn, Na, Rb, Sc, and Zn. Ten fragments of maize plants (dry ash) were analysed: leaves sheaths, beads, stumps, peduncles, spikes, unfruitfuls, interknots, knots, and corn husks, with a content distribution of the elements from percent to ppm. A precision of 5-7 % has been achieved on the basis of replicate analysis. The method is relatively simple and suitable for the analysis of biological samples. (Author)

  7. The five times ten things everyone should have had in their hands before they are ten and two years old.

    Science.gov (United States)

    Hut, R.; Poot, A.

    2017-12-01

    To train the young ones to become people that make stuff, I present the five times ten things we use a lot that everyone should have used before they are ten and two years old. I will bring at least two times ten of these things and show them live to you! And: I will bring a large paper for you to bring home with those five times ten things on it to put in the hands of your kids!

  8. A proposal for the measurement of Rashba and Dresselhaus spin–orbit interaction strengths in a single sample

    International Nuclear Information System (INIS)

    Maiti, Santanu K.; Sil, Shreekantha; Chakrabarti, Arunava

    2012-01-01

    We establish an exact analytical treatment for the determination of the strengths of the Rashba and Dresselhaus spin–orbit interactions in a single sample by measuring persistent spin current. A hidden symmetry is exploited in the Hamiltonian to show that the spin current vanishes when the strength of the Dresselhaus interaction becomes equal to the strength of the Rashba term. The results are sustained even in the presence of disorder and thus an experiment in this regard will be challenging. -- Highlights: ► An exact analytical treatment is given for the measurement of spin–orbit interaction strengths in a single sample. ► Persistent spin current is calculated. ► Our present analysis gives us confidence to propose an experiment in this line.

  9. Econometric Assessment of "One Minute" Paper as a Pedagogic Tool

    Science.gov (United States)

    Das, Amaresh

    2010-01-01

    This paper makes an econometric testing of one-minute paper used as a tool to manage and assess instruction in my statistics class. One of our findings is that the one minute paper when I have tested it by using an OLS estimate in a controlled Vs experimental design framework is found to statistically significant and effective in enhancing…

  10. Single blood-Hg samples can result in exposure misclassification: temporal monitoring within the Japanese community (United States

    Directory of Open Access Journals (Sweden)

    Tsuchiya Ami

    2012-06-01

    Full Text Available Abstract Background The most prominent non-occupational source of exposure to methylmercury is the consumption of fish. In this study we examine a fish consuming population to determine the extent of temporal exposure and investigate the extent to which single time estimates of methylmercury exposure based on blood-Hg concentration can provide reliable estimates of longer-term average exposure. Methods Blood-mercury levels were obtained from a portion of the Arsenic Mercury Intake Biometric Study (AMIBS cohort. Specifically, 56 Japanese women residing in the Puget Sound area of Washington State, US were sampled on three occasions across a one-year period. Results An average of 135 days separated samples, with mean blood-mercury levels for the visits being 5.1, 6.6 and 5.0 μg/l and geometric means being 2.7, 4.5 and 3.1 μg/l. The blood-mercury levels in this group exceed national averages with geometric means for two of the visits being between the 90th and 95th percentiles of nationally observed levels and the lowest geometric mean being between the 75th and 90th percentile. Group means were not significantly different across sampling periods suggesting that exposure of combined subjects remained relatively constant. Comparing intra-individual results over time did not reveal a strong correlation among visits (r = 0.19, 0.50, 0.63 between 1st and 2nd, 2nd and 3rd, and 1st and 3rd sample results, respectively. In comparing blood-mercury levels across two sampling interval combinations (1st and 2nd, 2nd and 3rd, and 1st and 3rd visits, respectively, 58% (n = 34, 53% (n = 31 and 29% (n = 17 of the individuals had at least a 100% difference in blood-Hg levels. Conclusions Point estimates of blood-mercury, when compared with three sample averages, may not reflect temporal variability and individual exposures estimated on the basis of single blood samples should be treated with caution as indicators of long-term exposure

  11. Measurement of regional cerebral blood flow using one-point arterial blood sampling and microsphere model with 123I-IMP. Correction of one-point arterial sampling count by whole brain count ratio

    International Nuclear Information System (INIS)

    Makino, Kenichi; Masuda, Yasuhiko; Gotoh, Satoshi

    1998-01-01

    The experimental subjects were 189 patients with cerebrovascular disorders. 123 I-IMP, 222 MBq, was administered by intravenous infusion. Continuous arterial blood sampling was carried out for 5 minutes, and arterial blood was also sampled once at 5 minutes after 123 I-IMP administration. Then the whole blood count of the one-point arterial sampling was compared with the octanol-extracted count of the continuous arterial sampling. A positive correlation was found between the two values. The ratio of the continuous sampling octanol-extracted count (OC) to the one-point sampling whole blood count (TC5) was compared with the whole brain count ratio (5:29 ratio, Cn) using 1-minute planar SPECT images, centering on 5 and 29 minutes after 123 I-IMP administration. Correlation was found between the two values. The following relationship was shown from the correlation equation. OC/TC5=0.390969 x Cn-0.08924. Based on this correlation equation, we calculated the theoretical continuous arterial sampling octanol-extracted count (COC). COC=TC5 x (0.390969 x Cn-0.08924). There was good correlation between the value calculated with this equation and the actually measured value. The coefficient improved to r=0.94 from the r=0.87 obtained before using the 5:29 ratio for correction. For 23 of these 189 cases, another one-point arterial sampling was carried out at 6, 7, 8, 9 and 10 minutes after the administration of 123 I-IMP. The correlation coefficient was also improved for these other point samplings when this correction method using the 5:29 ratio was applied. It was concluded that it is possible to obtain highly accurate input functions, i.e., calculated continuous arterial sampling octanol-extracted counts, using one-point arterial sampling whole blood counts by performing correction using the 5:29 ratio. (K.H.)

  12. Multiwavelength Variability Study of the Classical BL Lac Object PKS 0735+178 on Timescales Ranging from Decades to Minutes

    Energy Technology Data Exchange (ETDEWEB)

    Goyal, Arti; Stawarz, Łukasz; Ostrowski, Michał; Soida, Marian [Astronomical Observatory of Jagiellonian University, ul. Orla 171, 30-244 Kraków (Poland); Larionov, Valeri [Astronomical Institute of St. Petersburg State University, Petrodvorets 198504 (Russian Federation); Gopal-Krishna [Centre for Excellence in Basic Sciences (CEBS), University of Mumbai campus (Kalina), Mumbai 400098 (India); Wiita, Paul J. [Department of Physics, The College of New Jersey, 2000 Pennington Road, Ewing, NJ 08628-0718 (United States); Joshi, Santosh [Aryabhatta Research Institute of Observational Sciences (ARIES), Manora Peak, Nainital 263002 (India); Agudo, Iván, E-mail: arti@oa.uj.edu.pl [Instituto de Astrofísica de Andalucía (CSIC), Apartado 3004, E–18080 Granada (Spain)

    2017-03-10

    We present the results of our power spectral analysis for the BL Lac object PKS 0735+178, utilizing the Fermi -LAT survey at high-energy γ -rays, several ground-based optical telescopes, and single-dish radio telescopes operating at GHz frequencies. The novelty of our approach is that, by combining long-term and densely sampled intra-night light curves in the optical regime, we were able to construct for the first time the optical power spectrum of the blazar for a time domain extending from 23 years down to minutes. Our analysis reveals that: (1) the optical variability is consistent with a pure red noise, for which the power spectral density can be well approximated by a single power law throughout the entire time domain probed; (2) the slope of power spectral density at high-energy γ -rays (∼1) is significantly flatter than that found at radio and optical frequencies (∼2) within the corresponding time variability range; (3) for the derived power spectra, we did not detect any low-frequency flattening, nor do we see any evidence for cutoffs at the highest frequencies down to the noise floor levels due to measurement uncertainties. We interpret our findings in terms of a model where the blazar variability is generated by the underlying single stochastic process (at radio and optical frequencies), or a linear superposition of such processes (in the γ -ray regime). Along with the detailed PSD analysis, we also present the results of our extended (1998–2015) intra-night optical monitoring program and newly acquired optical photo-polarimetric data for the source.

  13. A single lysis solution for the analysis of tissue samples by different proteomic technologies

    DEFF Research Database (Denmark)

    Gromov, P.; Celis, J.E.; Gromova, I.

    2008-01-01

    -based proteomics (reverse-phase lysate arrays or direct antibody arrays), allowing the direct comparison of qualitative and quantitative data yielded by these technologies when applied to the same samples. The usefulness of the CLB1 solution for gel-based proteomics was further established by 2D PAGE analysis...... dissease, is driving scientists to increasingly use clinically relevant samples for biomarker and target discovery. Tissues are heterogeneous and as a result optimization of sample preparation is critical for generating accurate, representative, and highly reproducible quantitative data. Although a large...... number of protocols for preparation of tissue lysates has been published, so far no single recipe is able to provide a "one-size fits all" solubilization procedure that can be used to analyse the same lysate using different proteomics technologies. Here we present evidence showing that cell lysis buffer...

  14. Temperature dependence of the early degradation in a-Si solar cells; Amorphous Si taiyo denchi no shoki rekka no ondo izonsei

    Energy Technology Data Exchange (ETDEWEB)

    Takahisa, K; Kojima, T; Nakamura, K; Koyanagi, T; Yanagisawa, T [Electrotechnical Laboratory, Tsukuba (Japan)

    1997-11-25

    Discussions were given on early degradation in up to about ten minutes in amorphous silicon solar cells. The experiment has used a model cell of single junction layer for power use with a Glass/ITO/P-i-n:a-Si/Al structure. Test samples were annealed at 130 degC for 30 minutes to eliminate hysteresis of degradation during storage. Xenon was used as an irradiation light source, and the temperatures were varied from 0 to 100 degC and the measurement time was set to 0.1 to 500 minutes. The result of the experiment may be summarized as follows: with regard to time-based degradation pattern for conversion efficiency, the tilt of a pattern to express degradation rate varies with temperature conditions, and changes in 10 to 20 minutes of light irradiation as a boundary; in long-term degradation after 20 minutes, the higher the environmental temperature, the lower the degradation is suppressed, but the rate of initial degradation up to about 10 minutes is higher as the higher the temperature; and the degradation rate increases as the higher the temperature in the initial degradation of about 10 minutes, whereas, corresponding to this fact, it is estimated that a phenomenon is involved, in which carrier recombination defect may increase. 4 refs., 7 figs., 1 tab.

  15. Study of phosphors determination in biological samples

    International Nuclear Information System (INIS)

    Oliveira, Rosangela Magda de.

    1994-01-01

    In this paper, phosphors determination by neutron activation analysis in milk and bone samples was studied employing both instrumental and radiochemical separation methods. The analysis with radiochemistry separation consisted of the simultaneous irradiation of the samples and standards during 30 minutes, dissolution of the samples, hold back carrier, addition precipitation of phosphorus with ammonium phosphomolibdate (A.M.P.) and phosphorus-32 by counting by using Geiger-Mueller detector. The instrumental analysis consisted of the simultaneous irradiation of the samples and standards during 30 minutes, transfer of the samples into a counting planchet and measurement of the beta radiation emitted by phosphorus-32, after a suitable decay period. After the phosphorus analysis methods were established they were applied to both commercial milk and animal bone samples, and data obtained in the instrumental and radiochemical separation methods for each sample, were compared between themselves. In this work, it became possible to obtain analysis methods for phosphorus that can be applied independently of the sample quantity available, and the phosphorus content in the samples or interference that can be present in them. (author). 51 refs., 7 figs., 4 tabs

  16. Transcutaneous electrical nerve stimulation (TENS reduces pain and postpones the need for pharmacological analgesia during labour: a randomised trial

    Directory of Open Access Journals (Sweden)

    Licia Santos Santana

    2016-01-01

    Full Text Available Questions: In the active phase of the first stage of labour, does transcutaneous electrical nerve stimulation (TENS relieve pain or change its location? Does TENS delay the request for neuraxial analgesia during labour? Does TENS produce any harmful effects in the mother or the foetus? Are women in labour satisfied with the care provided? Design: Randomised trial with concealed allocation, assessor blinding for some outcomes, and intention-to-treat analysis. Participants: Forty-six low-risk, primigravida parturients with a gestational age > 37 weeks, cervical dilation of 4 cm, and without the use of any medications from hospital admission until randomisation. Intervention: The principal investigator applied TENS to the experimental group for 30 minutes starting at the beginning of the active phase of labour. A second investigator assessed the outcomes in both the control and experimental groups. Both groups received routine perinatal care. Outcome measures: The primary outcome was pain severity after the intervention period, which was assessed using the 100-mm visual analogue scale. Secondary outcomes included: pain location, duration of the active phase of labour, time to pharmacological labour analgesia, mode of birth, neonatal outcomes, and the participant's satisfaction with the care provided. Results: After the intervention, a significant mean difference in change in pain of 15 mm was observed favouring the experimental group (95% CI 2 to 27. The application of TENS did not alter the location or distribution of the pain. The mean time to pharmacological analgesia after the intervention was 5.0 hours (95% CI 4.1 to 5.9 longer in the experimental group. The intervention did not significantly impact the other maternal and neonatal outcomes. Participants in both groups were satisfied with the care provided during labour. Conclusion: TENS produces a significant decrease in pain during labour and postpones the need for pharmacological

  17. Tens bij bevallingen

    NARCIS (Netherlands)

    Tuin-Nuis, F.D.F.

    2000-01-01

    TENS (Transcutane Electrische Neuro Stimulatie) is een pijnverlichtingsmethode die berust op de Gate Control Theory van Melzack en Wall. Door middel van electrische pulsen via de huid zou de geleiding van nociceptieve signalen (pijnprikkels) worden beïnvloed en zou het lichaam endorfinen aanmaken:

  18. A technique for extracting blood samples from mice in fire toxicity tests

    Science.gov (United States)

    Bucci, T. J.; Hilado, C. J.; Lopez, M. T.

    1976-01-01

    The extraction of adequate blood samples from moribund and dead mice has been a problem because of the small quantity of blood in each animal and the short time available between the animals' death and coagulation of the blood. These difficulties are particularly critical in fire toxicity tests because removal of the test animals while observing proper safety precautions for personnel is time-consuming. Techniques for extracting blood samples from mice were evaluated, and a technique was developed to obtain up to 0.8 ml of blood from a single mouse after death. The technique involves rapid exposure and cutting of the posterior vena cava and accumulation of blood in the peritoneal space. Blood samples of 0.5 ml or more from individual mice have been consistently obtained as much as 16 minutes after apparent death. Results of carboxyhemoglobin analyses of blood appeared reproducible and consistent with carbon monoxide concentrations in the exposure chamber.

  19. Detection of minute strain in very local areas of materials by using an X-ray microbeam

    CERN Document Server

    Matsui, J; Tsusaka, Y; Kimura, S

    2003-01-01

    In order to analyze the local minute strain in semiconductor materials and devices, we have demonstrated formation of X-ray microbeams by using asymmetric Bragg reflections of the crystal and a zone plate or cylindrical mirror combined with synchrotron radiation. A series of X-ray rocking curves have been obtained by scanning the sample with using the X-ray microbeam. In addition, reciprocal space maps have also been obtained by inserting an analyzer crystal behind the sample. From these data, information on the strain distribution can be obtained for various samples, such as the strain near SiO sub 2 /Si film edges, that in silicon-on-insulator (SOI) crystals, and that in InGaAsP semiconductor laser stripes. (author)

  20. Does transcutaneous electrical nerve stimulation (TENS) alleviate the pain experienced during bone marrow sampling in addition to standard techniques? A randomised, double-blinded, controlled trial.

    Science.gov (United States)

    Tucker, David L; Rockett, Mark; Hasan, Mehedi; Poplar, Sarah; Rule, Simon A

    2015-06-01

    Bone marrow aspiration and trephine (BMAT) biopsies remain important tests in haematology. However, the procedures can be moderately to severely painful despite standard methods of pain relief. To test the efficacy of transcutaneous electrical nerve stimulation (TENS) in alleviating the pain from BMAT in addition to standard analgesia using a numerical pain rating scale (NRS). 70 patients requiring BMAT were randomised (1:1) in a double-blind, placebo-controlled trial. -35 patients received TENS impulses at a strong but comfortable amplitude (intervention group) and 35 patients received TENS impulses just above the sensory threshold (control group) (median pulse amplitude 20 and 7 mA, respectively). Patients and operators were blinded to group allocation. Pain assessments were made using a numerical pain scale completed after the procedure. No significant difference in NRS pain recalled after the procedure was detected (median pain score 5.7 (95% CI 4.8 to 6.6) in control vs 5.6 (95% CI 4.8 to 6.4) in the intervention group). However, 100% of patients who had previous experience of BMAT and >94% of participants overall felt they benefited from using TENS and would recommend it to others for this procedure. There were no side effects from the TENS device, and it was well tolerated. TENS is a safe, non-invasive adjunct to analgesia for reducing pain during bone marrow biopsy and provides a subjective benefit to most users; however, no objective difference in pain scores was detected when using TENS in this randomised controlled study. NCT02005354. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  1. Tourniquet Deflation Prior to 20 Minutes in Upper Extremity Intravenous Regional Anesthesia.

    Science.gov (United States)

    Gurich, Richard W; Langan, Justin W; Teasdall, Robert J; Tanner, Stephanie L; Sanders, John L

    2018-03-01

    Bier blocks, or intravenous regional anesthesia (IVRA), are a method of anesthesia for upper extremity surgeries. This study reports our experience with tourniquet deflation prior to 20 minutes with upper extremity IVRA. This study was designed as a retrospective cohort analysis. Records, including intraoperative and immediate postoperative anesthesia notes, of 430 patients who underwent IVRA with an upper extremity Bier block and a corresponding tourniquet time of less than 20 minutes were reviewed. Patient demographics, procedure(s) performed, American Society of Anesthesiologists scores, volume of lidocaine used in Bier block, tourniquet time, and any complications were recorded. This cohort consisted of 127 males and 303 females. The 3 most common procedures performed were carpal tunnel release (315), trigger finger release (47), and excision of masses (34). The average tourniquet time for this cohort was 16 minutes (range, 9-19 minutes), and the average volume of lidocaine (0.5% plain) injected was 44 mL (range, 30-70 mL). A tourniquet time of 17 minutes or less was observed in 339 patients, and 170 patients had tourniquet times of 15 minutes or less. Five complications were recorded: intraoperative vomiting, mild postoperative nausea/vomiting, severe postoperative nausea and vomiting, and transient postoperative hypotension that responded to a fluid bolus. No major complications were observed in our cohort of upper extremity IVRA and tourniquet times of less than 20 minutes. Several variables play a role in the safety of upper extremity IVRA.

  2. Appropriate xenon-inhalation time in xenon-enhanced CT using the end-tidal gas-sampling method

    Energy Technology Data Exchange (ETDEWEB)

    Asada, Hideo; Furuhata, Shigeru; Onozuka, Satoshi; Uchida, Koichi; Fujii, Koji; Suga, Sadao; Kawase, Takeshi; Toya, Shigeo; Shiga, Hayao

    1988-12-01

    For the end-tidal gas-sampling method of xenon-enhanced CT (Xe-CT), the respective functional images of K, lambda, and the regional cerebral blood flow (rCBF) were studied and compared using the data at 7-, 10-, 15- and 25-minute inhalations. The most appropriate inhalation time of xenon gas was evaluated in 14 clinical cases. An end-tidal xenon curve which represents the arterial xenon concentration was monitored with a xenon analyzer; the xenon concentration was gradually increased to a level of 50% by using a xenon inhalator with a closed circuit to prevent the overestimation of the xenon concentration sampled from the mask. Serial CT scans were taken over a period of 25 minutes of inhalation. The functional images of K, lambda, and rCBF were calculated for serial CT scans for 7, 10, 15 and 25 minutes using Fick's equation. Those various images and absolute values were then compared. The rCBF value of a 15-minute inhalation was approximately 15% greater than that of 25 minutes, while the values of K, lambda, rCBF from a 15-minute inhalation were significantly correlated to those from 25 minutes. The regression line made it possible to estimate 25-minute inhalation values from those of 15 minutes. In imaging, the rCBF mapping of the 15-minute inhalation was found to be more reliable than that of 25 minutes. This study suggests that the minimal time of xenon inhalation is 15 minutes for the end-tidal gas-sampling method. A longer inhalation may be necessary for the estimation of rCBF in the low-flow area, such as the white matter or the pathological region.

  3. Minute ventilation of cyclists, car and bus passengers: an experimental study.

    NARCIS (Netherlands)

    Zuurbier, M.; Hoek, G.; van den Hazel, P.J.; Brunekreef, B.

    2009-01-01

    ABSTRACT: BACKGROUND: Differences in minute ventilation between cyclists, pedestrians and other commuters influence inhaled doses of air pollution. This study estimates minute ventilation of cyclists, car and bus passengers, as part of a study on health effects of commuters' exposure to air

  4. A review of single-sample-based models and other approaches for radiocarbon dating of dissolved inorganic carbon in groundwater

    Science.gov (United States)

    Han, L. F; Plummer, Niel

    2016-01-01

    Numerous methods have been proposed to estimate the pre-nuclear-detonation 14C content of dissolved inorganic carbon (DIC) recharged to groundwater that has been corrected/adjusted for geochemical processes in the absence of radioactive decay (14C0) - a quantity that is essential for estimation of radiocarbon age of DIC in groundwater. The models/approaches most commonly used are grouped as follows: (1) single-sample-based models, (2) a statistical approach based on the observed (curved) relationship between 14C and δ13C data for the aquifer, and (3) the geochemical mass-balance approach that constructs adjustment models accounting for all the geochemical reactions known to occur along a groundwater flow path. This review discusses first the geochemical processes behind each of the single-sample-based models, followed by discussions of the statistical approach and the geochemical mass-balance approach. Finally, the applications, advantages and limitations of the three groups of models/approaches are discussed.The single-sample-based models constitute the prevailing use of 14C data in hydrogeology and hydrological studies. This is in part because the models are applied to an individual water sample to estimate the 14C age, therefore the measurement data are easily available. These models have been shown to provide realistic radiocarbon ages in many studies. However, they usually are limited to simple carbonate aquifers and selection of model may have significant effects on 14C0 often resulting in a wide range of estimates of 14C ages.Of the single-sample-based models, four are recommended for the estimation of 14C0 of DIC in groundwater: Pearson's model, (Ingerson and Pearson, 1964; Pearson and White, 1967), Han & Plummer's model (Han and Plummer, 2013), the IAEA model (Gonfiantini, 1972; Salem et al., 1980), and Oeschger's model (Geyh, 2000). These four models include all processes considered in single-sample-based models, and can be used in different ranges of

  5. Investigation of applicability of extrapolation method for sample field determination in single-yoke measuring setup

    Czech Academy of Sciences Publication Activity Database

    Stupakov, Oleksandr

    2006-01-01

    Roč. 307, - (2006), s. 279-287 ISSN 0304-8853 R&D Projects: GA AV ČR(CZ) 1QS100100508 Institutional research plan: CEZ:AV0Z10100520 Keywords : magnetic measurement * open magnetic sample * surface field determination * single-yoke setup * magnetic non-destructive testing Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 1.212, year: 2006

  6. Increasing intensity of TENS prevents analgesic tolerance in rats

    Science.gov (United States)

    Sato, Karina L.; Sanada, Luciana S.; Rakel, Barbara A.; Sluka, Kathleen A.

    2012-01-01

    Transcutaneous electrical nerve stimulation (TENS) reduces hyperalgesia and pain. Both low frequency (LF) and high frequency (HF) TENS, delivered at the same intensity (90% motor threshold (MT)) daily, result in analgesic tolerance with repeated use by the 5th day of treatment. Thecurrentstudytestedif 1) increasingintensityby 10% per daypreventsthedevelopmentoftolerance to repeated TENS, and 2) iflowerintensity TENS (50 % MT) produces an equivalentreduction in hyperalgesia when compared to 90% MT TENS. Sprague-Dawley rats with unilateral knee joint inflammation (3% carrageenan) were separated according to the intensity of TENS used: Sham, 50% LF, 50% HF, 90% LF, 90% HF, and increased intensity by 10% per day (LF and HF). The reduced mechanical withdrawal threshold following the induction of inflammation was reversed by application of TENS applied at 90% MT and increasing intensity for the first 4 days. On the 5th day, the groups that received 90% MT intensity showed tolerance. Nevertheless, the group that received an increased intensity on each day still showed a reversal of the mechanical withdrawal threshold with TENS. These results show that the development of tolerance can be delayed by increasing intensity of TENS. PMID:22858165

  7. A 15.7-Minute AM CVn Binary Discovered in K2

    Science.gov (United States)

    Green, M. J.; Hermes, J. J.; Marsh, T. R.; Steeghs, D. T. H.; Bell, Keaton J.; Littlefair, S. P.; Parsons, S. G.; Dennihy, E.; Fuchs, J. T.; Reding, J. S.; Kaiser, B. C.; Ashley, R. P.; Breedt, E.; Dhillon, V. S.; Gentile Fusillo, N. P.; Kerry, P.; Sahman, D. I.

    2018-04-01

    We present the discovery of SDSS J135154.46-064309.0, a short-period variable observed using 30-minute cadence photometry in K2 Campaign 6. Follow-up spectroscopy and high-speed photometry support a classification as a new member of the rare class of ultracompact accreting binaries known as AM CVn stars. The spectroscopic orbital period of 15.65 ± 0.12 minutes makes this system the fourth-shortest period AM CVn known, and the second system of this type to be discovered by the Kepler spacecraft. The K2 data show photometric periods at 15.7306 ± 0.0003 minutes, 16.1121 ± 0.0004 minutes and 664.82 ± 0.06 minutes, which we identify as the orbital period, superhump period, and disc precession period, respectively. From the superhump and orbital periods we estimate the binary mass ratio q = M2/M1 = 0.111 ± 0.005, though this method of mass ratio determination may not be well calibrated for helium-dominated binaries. This system is likely to be a bright foreground source of gravitational waves in the frequency range detectable by LISA, and may be of use as a calibration source if future studies are able to constrain the masses of its stellar components.

  8. Determination of the technetium-99m mercaptoacetyltriglycine plasma clearance in children by means of a single blood sample: a multicentre study

    International Nuclear Information System (INIS)

    Piepsz, A.; Gordon, I.; Hahn, K.; Kolinska, J.; Kotzerke, J.; Sixt, R.

    1993-01-01

    A multicentree European study was undertaken in order to determine a reasonable algorithm allowing the determination of overall technetium-99m mercaptoacetyltriglycine clearance using a single blood sample. Employing multiple blood sample clearance as a reference method, it was shown that an acceptable estimation of the MAG3 renal clearance could be obtained using a blood sample taken at any time between 30 and 40 min after tracer injection. After correction for body surface area comparison of clearance determined using (a) the single blood sample and (b) the multiple blood samples provided a coefficient of correlation of 0.949 and an SEE of 27 ml/min. This algorithm is valid for clearance values higher than 100 ml/min/1.73 m 2 and for children older than 1 year of age. (orig.)

  9. Device for sampling HTGR recycle fuel particles

    International Nuclear Information System (INIS)

    Suchomel, R.R.; Lackey, W.J.

    1977-03-01

    Devices for sampling High-Temperature Gas-Cooled Reactor fuel microspheres were evaluated. Analysis of samples obtained with each of two specially designed passive samplers were compared with data generated by more common techniques. A ten-stage two-way sampler was found to produce a representative sample with a constant batch-to-sample ratio

  10. 39 CFR 6.5 - Minutes of meetings.

    Science.gov (United States)

    2010-07-01

    ... 39 Postal Service 1 2010-07-01 2010-07-01 false Minutes of meetings. 6.5 Section 6.5 Postal Service UNITED STATES POSTAL SERVICE THE BOARD OF GOVERNORS OF THE U.S. POSTAL SERVICE MEETINGS (ARTICLE...) or 39 U.S.C. 410(c). ...

  11. Effect of pencil grasp on the speed and legibility of handwriting after a 10-minute copy task in Grade 4 children.

    Science.gov (United States)

    Schwellnus, Heidi; Carnahan, Heather; Kushki, Azadeh; Polatajko, Helene; Missiuna, Cheryl; Chau, Tom

    2012-06-01

    To investigate the impact of common pencil grasp patterns on the speed and legibility of handwriting after a 10-minute copy task, intended to induce muscle fatigue, in typically developing children and in those non-proficient in handwriting. A total of 120 Grade 4 students completed a standardised handwriting assessment before and after a 10-minute copy task. The students indicated the perceived difficulty of the handwriting task at baseline and after 10 minutes. The students also completed a self-report questionnaire regarding their handwriting proficiency upon completion. The majority of the students rated higher effort after the 10-minute copy task than at baseline (rank sum: P = 0.00001). The effort ratings were similar for the different grasp patterns (multiple linear regression: F = 0.37, P = 0.895). For both typically developing children and those with handwriting issues, the legibility of the writing samples decreased after the 10-minute copy task but the speed of writing increased. CONCLUSIONS AND SIGNIFICANCE OF THE STUDY: The quality of the handwriting decreased after the 10-minute copy task; however, there was no difference in the quality or speed scores among the different pencil grasps before and after the copy task. The dynamic tripod pencil grasp did not offer any advantage over the lateral tripod or the dynamic or lateral quadrupod pencil grasps in terms of quality of handwriting after a 10-minute copy task. These four pencil grasp patterns performed equivalently. Our findings question the practice of having students adopt the dynamic tripod pencil grasp. © 2012 The Authors Australian Occupational Therapy Journal © 2012 Occupational Therapy Australia.

  12. Spatial resolution of 2D ionization chamber arrays for IMRT dose verification: single-detector size and sampling step width

    International Nuclear Information System (INIS)

    Poppe, Bjoern; Djouguela, Armand; Blechschmidt, Arne; Willborn, Kay; Ruehmann, Antje; Harder, Dietrich

    2007-01-01

    The spatial resolution of 2D detector arrays equipped with ionization chambers or diodes, used for the dose verification of IMRT treatment plans, is limited by the size of the single detector and the centre-to-centre distance between the detectors. Optimization criteria with regard to these parameters have been developed by combining concepts of dosimetry and pattern analysis. The 2D-ARRAY Type 10024 (PTW-Freiburg, Germany), single-chamber cross section 5 x 5 mm 2 , centre-to-centre distance between chambers in each row and column 10 mm, served as an example. Additional frames of given dose distributions can be taken by shifting the whole array parallel or perpendicular to the MLC leaves by, e.g., 5 mm. The size of the single detector is characterized by its lateral response function, a trapezoid with 5 mm top width and 9 mm base width. Therefore, values measured with the 2D array are regarded as sample values from the convolution product of the accelerator generated dose distribution and this lateral response function. Consequently, the dose verification, e.g., by means of the gamma index, is performed by comparing the measured values of the 2D array with the values of the convolution product of the treatment planning system (TPS) calculated dose distribution and the single-detector lateral response function. Sufficiently small misalignments of the measured dose distributions in comparison with the calculated ones can be detected since the lateral response function is symmetric with respect to the centre of the chamber, and the change of dose gradients due to the convolution is sufficiently small. The sampling step width of the 2D array should provide a set of sample values representative of the sampled distribution, which is achieved if the highest spatial frequency contained in this function does not exceed the 'Nyquist frequency', one half of the sampling frequency. Since the convolution products of IMRT-typical dose distributions and the single

  13. Column-Parallel Single Slope ADC with Digital Correlated Multiple Sampling for Low Noise CMOS Image Sensors

    NARCIS (Netherlands)

    Chen, Y.; Theuwissen, A.J.P.; Chae, Y.

    2011-01-01

    This paper presents a low noise CMOS image sensor (CIS) using 10/12 bit configurable column-parallel single slope ADCs (SS-ADCs) and digital correlated multiple sampling (CMS). The sensor used is a conventional 4T active pixel with a pinned-photodiode as photon detector. The test sensor was

  14. Individual renal plasma flow determination in 2 minutes

    International Nuclear Information System (INIS)

    Schlegel, J.U.; Hamway, S.A.

    1976-01-01

    A method is described for determining effective renal plasma flow, using the renal counts 1 to 2 minutes after injection and applying background subtraction as a ratio to the total amount of radioactivity injected intravenously with appropriate correction for kidney depth. It appears that this simple approach for determination of effective renal plasma flow within a matter of 2 minutes is accurate and reliable, and should be useful for a number of applications when it is important to determine total and individual renal plasma flow. The approach is recommended as a screening procedure in lieu of the determination of blood urea nitrogen and serum creatinine, with the additional advantages of gross morphology and determination of individual renal plasma flow in an absolute as well as relative manner

  15. Effect of Environmental and Behavioral Interventions on Pain Intensity in Preterm Infants for Heel Prick Blood Sampling in the Neonatal Intensive Care Unit.

    Science.gov (United States)

    Baharlooei, Fatemeh; Marofi, Maryam; Abdeyazdan, Zahra

    2017-01-01

    Recent researches suggest that preterm infants understand pain and stress. Because of the wide range of effects of pain on infants, the present study was conducted on the effect of environmental and behavioral interventions on pain due to heel-prick blood sampling in preterm infants. A clinical trial was conducted among 32 infants with gestational age of 32-37 weeks in the intervention and control groups. The effects of noise reduction by earplugs, light reduction by blindfolds, reduction of nursing manipulation, and creation of intrauterine position for neonates, 30 minutes before taking blood samples until 30 minutes after it, were measured during the intervention stage. Data were collected using the Neonatal Infant Pain Scale (NIPS) in 5 stages (before intervention, 2 minutes before sampling, during the sampling, and 5 minutes and 30 minutes after the sampling). The data were analyzed using analysis of variance (ANOVA) and paired t -test in SPSS software. The paired t -test results showed no significant differences between the control and intervention stages in terms of pain scores at base time ( P = 0.42) and 2 minutes before sampling ( P = 0.12). However, at the sampling time ( P = 0.0), and 5 minutes ( P = 0.001) and 30 minutes after the sampling ( P = 0.001), mean pain score in the intervention stage was significantly less than that in the control stage. Based on the findings, environmental and behavioral interventions reduced pain and facilitated heel-prick blood sampling in preterm infants.

  16. Transcutaneous electrical nerve stimulation (TENS) for pain relief in labour.

    Science.gov (United States)

    Dowswell, Therese; Bedwell, Carol; Lavender, Tina; Neilson, James P

    2009-04-15

    Transcutaneous nerve stimulation (TENS) has been proposed as a means of reducing pain in labour. The TENS unit emits low-voltage electrical impulses which vary in frequency and intensity. During labour, TENS electrodes are generally placed on the lower back, although TENS may be used to stimulate acupuncture points or other parts of the body. The physiological mechanisms whereby TENS relieves pain are uncertain. The TENS unit is frequently operated by women, which may increase sense of control in labour. To assess the effects of TENS on pain in labour. We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (November 2008). Randomised controlled trials comparing women receiving TENS for pain relief in labour versus routine care, alternative pharmacological methods of pain relief, or placebo devices. We included all types of TENS machines. Two review authors assessed for inclusion all trials identified by the search strategy, carried out data extraction and assessed risk of bias. We have recorded reasons for excluding studies. The search identified 25 studies; we excluded six and included 19 studies including 1671 women. Fifteen examined TENS applied to the back, two to acupuncture points and two to the cranium. Overall, there was little difference in pain ratings between TENS and control groups, although women receiving TENS to acupuncture points were less likely to report severe pain (risk ratio 0.41, 95% confidence interval 0.32 to 0.55). The majority of women using TENS said they would be willing to use it again in a future labour. Where TENS was used as an adjunct to epidural analgesia there was no evidence that it reduced pain. There was no consistent evidence that TENS had any impact on interventions and outcomes in labour. There was little information on outcomes for mothers and babies. No adverse events were reported. There is only limited evidence that TENS reduces pain in labour and it does not seem to have any impact (either positive or

  17. 12 CFR 407.6 - Transcripts, recordings and minutes of closed meetings.

    Science.gov (United States)

    2010-01-01

    ... 12 Banks and Banking 4 2010-01-01 2010-01-01 false Transcripts, recordings and minutes of closed meetings. 407.6 Section 407.6 Banks and Banking EXPORT-IMPORT BANK OF THE UNITED STATES REGULATIONS GOVERNING PUBLIC OBSERVATION OF EX-IM BANK MEETINGS § 407.6 Transcripts, recordings and minutes of closed...

  18. Jobs within a 30-minute transit ride - Service

    Data.gov (United States)

    U.S. Environmental Protection Agency — This mapping service summarizes the total number of jobs that can be reached within 30 minutes by transit. EPA modeled accessibility via transit by calculating total...

  19. Area G perimeter surface-soil and single-stage water sampling: Environmental surveillance for fiscal year 1993

    International Nuclear Information System (INIS)

    Conrad, R.; Childs, M.; Rivera-Dirks, C.; Coriz, F.

    1995-07-01

    Area G, in Technical Area 54, has been the principle facility at Los Alamos National Laboratory for the storage and disposal of low-level and transuranic (TRU) radioactive wastes since 1957. The current environmental investigation consisted of ESH-19 personnel who collected soil and single-stage water samples around the perimeter of Area G to characterize possible contaminant movement through surface-water runoff. These samples were analyzed for tritium, total uranium, isotopic plutonium, americium-241 (soil only), and cesium 137. The metals, mercury, lead, and barium, were analyzed using x-ray fluorescence

  20. Multiple 60-Minute Massages per Week Offer Relief for Chronic Neck Pain

    Science.gov (United States)

    ... W X Y Z Multiple 60-Minute Massages per Week Offer Relief for Chronic Neck Pain Share: © ... funded study found that multiple 60-minute massages per week were more effective than fewer or shorter ...

  1. Quantitative in-situ TEM nanotensile testing of single crystal Ni facilitated by a new sample preparation approach.

    Science.gov (United States)

    Samaeeaghmiyoni, Vahid; Idrissi, Hosni; Groten, Jonas; Schwaiger, Ruth; Schryvers, Dominique

    2017-03-01

    Twin-jet electro-polishing and Focused Ion Beam (FIB) were combined to produce small size Nickel single crystal specimens for quantitative in-situ nanotensile experiments in the transmission electron microscope. The combination of these techniques allows producing samples with nearly defect-free zones in the centre in contrast to conventional FIB-prepared samples. Since TEM investigations can be performed on the electro-polished samples prior to in-situ TEM straining, specimens with desired crystallographic orientation and initial microstructure can be prepared. The present results reveal a dislocation nucleation-controlled plasticity, in which small loops induced by FIB near the edges of the samples play a central role. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. Microbial quality of some commercial yoghurt samples in Awka ...

    African Journals Online (AJOL)

    Microbiological quality of ten commercial samples representing ten different brands of yoghurt marketed in Awka metropolis, Anambra State was assessed using standard microbiological procedures. The analysis carried out was aimed at determining the presence and level of both bacterial and fungal contaminants in the ...

  3. Observations related to hydrogen in powder and single crystal samples of YB2Cu3O7-δ

    International Nuclear Information System (INIS)

    Porath, D.; Grayevsky, A.; Kaplan, N.; Shaltiel, D.; Yaron, U.; Walker, E.

    1994-01-01

    New observations related to hydrogenation of YBa 2 Cu 3 O 7-δ (YBCO) are reported: (a) The effects of sample preparation on the H concentration in ''uncharged'' YBCO samples is investigated, and it is shown through nuclear magnetic resonance measurements that samples of YBCO prepared by ''standard'' solid-state reaction procedures may contain ab initio up to 0.2 atoms formula -1 of hydrogen. (b) It is demonstrated that one may introduce up to 0.3 atoms formula -1 into single crystal samples of YBCO without destroying the macroscopic crystal. The significance of the above observations is discussed briefly. (orig.)

  4. Reforming minute reserve policy in Germany. A step towards efficient markets?

    International Nuclear Information System (INIS)

    Rammerstorfer, Margarethe; Wagner, Christian

    2009-01-01

    The present paper provides an empirical assessment of the effects associated with the reorganization of minute reserve markets in Germany. As the aim of the regulator is to assure a competitive market with transparent pricing, we analyze whether the recent policy reform has had an impact on the dynamics of minute reserve prices. Our results show that the level and volatility of positive and negative minute reserve prices decreased substantially. Furthermore, we provide evidence that the degree of integration between reserve and spot markets has increased. Overall, prices reacted to the policy change in a manner that is in line with the regulator's objective. The reform can thus be viewed as a step towards an efficient reserve market. (author)

  5. A single action for the scalar-tensor theory of gravity

    International Nuclear Information System (INIS)

    Roxburgh, I.W.

    1977-01-01

    The standard form of the scalar-tensor theory gives eleven equations for eleven unknowns, the metric tensor Gsub(ij) and the scalar field phi. Here the scalar field is eliminated to produce a theory that has just ten equations for ten unknown gsub(ij). The resulting expression for the action of fields and matter is contained completely in a single expression. (author)

  6. Brachytherapy dose-volume histogram computations using optimized stratified sampling methods

    International Nuclear Information System (INIS)

    Karouzakis, K.; Lahanas, M.; Milickovic, N.; Giannouli, S.; Baltas, D.; Zamboglou, N.

    2002-01-01

    A stratified sampling method for the efficient repeated computation of dose-volume histograms (DVHs) in brachytherapy is presented as used for anatomy based brachytherapy optimization methods. The aim of the method is to reduce the number of sampling points required for the calculation of DVHs for the body and the PTV. From the DVHs are derived the quantities such as Conformity Index COIN and COIN integrals. This is achieved by using partial uniform distributed sampling points with a density in each region obtained from a survey of the gradients or the variance of the dose distribution in these regions. The shape of the sampling regions is adapted to the patient anatomy and the shape and size of the implant. For the application of this method a single preprocessing step is necessary which requires only a few seconds. Ten clinical implants were used to study the appropriate number of sampling points, given a required accuracy for quantities such as cumulative DVHs, COIN indices and COIN integrals. We found that DVHs of very large tissue volumes surrounding the PTV, and also COIN distributions, can be obtained using a factor of 5-10 times smaller the number of sampling points in comparison with uniform distributed points

  7. Transcutaneous electrical nerve stimulation (TENS) for pain management in labour

    Science.gov (United States)

    Dowswell, Therese; Bedwell, Carol; Lavender, Tina; Neilson, James P

    2014-01-01

    Background Transcutaneous nerve stimulation (TENS) has been proposed as a means of reducing pain in labour. The TENS unit emits low-voltage electrical impulses which vary in frequency and intensity. During labour, TENS electrodes are generally placed on the lower back, although TENS may be used to stimulate acupuncture points or other parts of the body. The physiological mechanisms whereby TENS relieves pain are uncertain. TENS machines are frequently operated by women, which may increase a sense of control in labour. Objectives To assess the effects of TENS on pain in labour. Search methods We searched the Cochrane Pregnancy and Childbirth Group’s Trials Register (30 April 2011) and reference lists of retrieved papers. Selection criteria Randomised controlled trials comparing women receiving TENS for pain management in labour versus routine care, alternative non-pharmacological methods of pain relief, or placebo devices. We included all types of TENS machines. Data collection and analysis Two review authors assessed for inclusion all trials identified by the search strategy, carried out data extraction and assessed risk of bias. We have recorded reasons for excluding studies. Main results Seventeen trials with 1466 women contribute data to the review. Thirteen examined TENS applied to the back, two to acupuncture points, and two to the cranium. Overall, there was little difference in pain ratings between TENS and control groups, although women receiving TENS to acupuncture points were less likely to report severe pain (average risk ratio 0.41, 95% confidence interval 0.31 to 0.54; measured in two studies). The majority of women using TENS said they would be willing to use it again in a future labour. Where TENS was used as an adjunct to epidural analgesia there was no evidence that it reduced pain. There was no consistent evidence that TENS had any impact on interventions and outcomes in labour. There was little information on outcomes for mothers and babies. No

  8. The 15-minute family interview: a family health strategy tool

    Directory of Open Access Journals (Sweden)

    Mariana Cristina Lobato dos Santos Ribeiro Silva

    2013-06-01

    Full Text Available The 15-minute family interview is a condensed form of the Calgary Family Assessment and Intervention Models (CFAM and CFIM that aims to contribute to the establishment of a therapeutic relationship between nurses and family and to implement interventions to promote health and suffering relief, even during brief interactions. This study investigated the experience of nurses from the Family Health Strategy (FHS who used the 15-minute interview on postpartum home. The qualitative research was conducted in three stages: participants' training program, utilization of the 15-minute family interview by participants, and interviews with nurses. The data were collected through semi-structured interviews with eight nurses. The thematic analysis revealed two main themes: dealing with the challenge of a new practice and evaluating the assignment. This work shows that this tool can be used to deepen relationships between nurses and families in the Family Health Strategy.

  9. A safety equipment list for rotary mode core sampling systems operation in single shell flammable gas tanks

    International Nuclear Information System (INIS)

    SMALLEY, J.L.

    1999-01-01

    This document identifies all interim safety equipment to be used for rotary mode core sampling of single-shell flammable gas tanks utilizing Rotary Mode Core Sampling systems (RMCS). This document provides the safety equipment for RMCS trucks HO-68K-4600, HO-68K-4647, trucks three and four respectively, and associated equipment. It is not intended to replace or supersede WHC-SD-WM-SEL-023, (Kelly 1991), or WHC-SD-WM-SEL-032, (Corbett 1994), which classifies 80-68K-4344 and HO-68K-4345 respectively. The term ''safety equipment'' refers to safety class (SC) and safety significant (SS) equipment, where equipment refers to structures, systems and components (SSC's). The identification of safety equipment in this document is based on the credited design safety features and analysis contained in the Authorization Basis (AB) for rotary mode core sampling operations in single-shell flammable gas tanks. This is an interim safety classification since the AB is interim. This document will be updated to reflect the final RMCS equipment safety classification designations upon completion of a final AB which will be implemented with the release of the Final Safety Analysis Report (FSAR)

  10. Four minutes for a patient, twenty seconds for a relative - an observational study at a university hospital

    Directory of Open Access Journals (Sweden)

    Xander Carola J

    2010-04-01

    Full Text Available Abstract Background In the modern hospital environment, increasing possibilities in medical examination techniques and increasing documentation tasks claim the physicians' energy and encroach on their time spent with patients. This study aimed to investigate how much time physicians at hospital wards spend on communication with patients and their families and how much time they spend on other specific work tasks. Methods A non-participatory, observational study was conducted in thirty-six wards at the University Medical Center Freiburg, a 1700-bed academic hospital in Germany. All wards belonging to the clinics of internal medicine, surgery, radiology, neurology, and to the clinic for gynaecology took part in the study. Thirty-four ward doctors from fifteen different medical departments were observed during a randomly chosen complete work day. The Physicians' time for communication with patients and relatives and time spent on different working tasks during one day of work were assessed. Results 374 working hours were analysed. On average, a physician's workday on a university hospital ward added up to 658.91 minutes (10 hrs 58 min; range 490 - 848 min. Looking at single items of time consumption on the evaluation sheet, discussions with colleagues ranked first with 150 minutes on average. Documentation and administrative requirements took an average time of 148 minutes per day and ranked second. Total time for communication with patients and their relatives was 85 minutes per physician and day. Consequently, the available time for communication was 4 minutes and 17 seconds for each patient on the ward and 20 seconds for his or her relatives. Physicians assessed themselves to communicate twice as long with patients and sevenfold with relatives than they did according to this study. Conclusions Workload and time pressure for physicians working on hospital wards are high. To offer excellent medical treatment combined with patient centred care and

  11. Interagency Advanced Power Group meeting minutes

    Energy Technology Data Exchange (ETDEWEB)

    1991-12-31

    This document contains the minutes and viewgraphs from a meeting of military personnel on the subject of power generation and distribution systems for military applications. Topics include heating and cooling systems for standard shelters, SDIO power programs, solar dynamic space power systems, hybrid solar dynamic/ photovoltaic systems, pulsed power technology, high-{Tc} superconductors, and actuators and other electronic equipment for aerospace vehicles. Attendees represented the US Air Force, Army, Navy, and NASA. (GHH)

  12. Interagency Advanced Power Group meeting minutes

    Energy Technology Data Exchange (ETDEWEB)

    1991-01-01

    This document contains the minutes and viewgraphs from a meeting of military personnel on the subject of power generation and distribution systems for military applications. Topics include heating and cooling systems for standard shelters, SDIO power programs, solar dynamic space power systems, hybrid solar dynamic/ photovoltaic systems, pulsed power technology, high-{Tc} superconductors, and actuators and other electronic equipment for aerospace vehicles. Attendees represented the US Air Force, Army, Navy, and NASA. (GHH)

  13. Determination of any gas composition using high energy molecular beams. Application to the simultaneous concentration measurement of ten pollutants in air

    International Nuclear Information System (INIS)

    Devienne, F.M.; Laugier, Lucette; Roustan, J.-C.; Clapier, Robert.

    1975-01-01

    A high energy argon beam collides the gas to be abalyzed in a special box. The ions formed are extracted and collide a target gas (such as argon) filling a collision chamber, some of them are dissociated. The number of these ions is measured by means of an electrostatic analyzer and an electron multiplier as detector. By this way, it is possible to measure the concentrations of ten or more gaseous pollutants in air in a time shorter than a minute. The method was applied to study the effluents of a jet; the concentrations in CO, NO, NO 2 , CO 2 and SO 2 were measured [fr

  14. The TEN-T core network and the Fehmarnbelt region

    DEFF Research Database (Denmark)

    Guasco, Clement Nicolas

    This note is a snapshot picture, taken in early 2014, that places the Green STRING corridor project within the context of the TEN-T strategy and gives a summarized overview on the impact of this strategy in the region. Chapter 1 contains a summary of the TEN-T strategy today, chapter 2 presents...... the sources used for this note, chapter 3 presents all the relevant EU regulations with direct impact on the development of TEN-T corridors, chapter 4 gives practical examples of the challenges for the development of TEN-T corridors, chapter 5 pre-sents the national initiatives related to the TEN-T corridor...

  15. Effect of environmental and behavioral interventions on pain intensity in preterm infants for heel prick blood sampling in the neonatal intensive care unit

    Directory of Open Access Journals (Sweden)

    Fatemeh Baharlooei

    2017-01-01

    Full Text Available Background: Recent researches suggest that preterm infants understand pain and stress. Because of the wide range of effects of pain on infants, the present study was conducted on the effect of environmental and behavioral interventions on pain due to heel-prick blood sampling in preterm infants. Materials and Methods: A clinical trial was conducted among 32 infants with gestational age of 32–37 weeks in the intervention and control groups. The effects of noise reduction by earplugs, light reduction by blindfolds, reduction of nursing manipulation, and creation of intrauterine position for neonates, 30 minutes before taking blood samples until 30 minutes after it, were measured during the intervention stage. Data were collected using the Neonatal Infant Pain Scale (NIPS in 5 stages (before intervention, 2 minutes before sampling, during the sampling, and 5 minutes and 30 minutes after the sampling. The data were analyzed using analysis of variance (ANOVA and paired t-test in SPSS software. Results: The paired t-test results showed no significant differences between the control and intervention stages in terms of pain scores at base time (P = 0.42 and 2 minutes before sampling (P = 0.12. However, at the sampling time (P = 0.0, and 5 minutes (P = 0.001 and 30 minutes after the sampling (P = 0.001, mean pain score in the intervention stage was significantly less than that in the control stage. Conclusions: Based on the findings, environmental and behavioral interventions reduced pain and facilitated heel-prick blood sampling in preterm infants.

  16. Investigations of the post-IR IRSL protocol applied to single K-feldspar grains from fluvial sediment samples

    International Nuclear Information System (INIS)

    Nian, Xiaomei; Bailey, Richard M.; Zhou, Liping

    2012-01-01

    The post-IR IRSL protocol with single K-feldspar grains was applied to three samples taken from a fluvial sedimentary sequence at the archaeological site of the Dali Man, Shaanxi Province, China. K-feldspar coarse grains were extracted for measurement. Approximately 30–40% of the grains were sufficiently bright to measure, and after application of rejection criteria based on signal strength, recuperation, recycling ratio and saturation dose, ∼10–15% of the grains were used for D e calculation. The relationship of signal decay rate and form of D e (t) with the recovery dose were investigated. The dose recovery ratios of the samples after initial bleaching with the four different light sources were within uncertainties of unity. No anomalous fading was observed. The over-dispersion of the recovered dose and D e values were similar, suggesting neither incomplete resetting of the post-IR IRSL signals nor spatially heterogeneous dose rates significantly affected the natural dose estimates. The values of D e obtained with the single K-feldspar grain post-IR IRSL protocol were in the range ∼400–490 Gy. Combining all of the measured single-grain signals for each of the individual samples (into a ‘synthetic single aliquot’) increased the D e estimates to the range ∼700–900 Gy, suggesting that the grains screened-out by the rejection criteria may have the potential to cause palaeodose over-estimation, although this finding requires a more extensive investigation. Thermally transferred signals were found in the single K-feldspar grains post-IR IRSL protocol, and the proportion of thermally transferred signal to test-dose OSL signal (stimulation at 290 °C) from the natural dose was higher than from regenerative doses, and the proportion was grain- and dose-dependent. As such, TT-post-IR IRSL signals at 290 °C have the potential to cause dose underestimation, although this may be reduced by using larger test-dose irradiations. Our study demonstrates

  17. A synthesis of ten years' tests on scale models of LMFBR steam generators at the CGVS facility

    International Nuclear Information System (INIS)

    Fontaine, J.P.; Quinet, J.L.

    1982-01-01

    Electricite de France has built a high power sodium heated steam generator (SG) facility (CGVS), capable of reproducing all possible operating conditions, to study the behaviour of scale-models of industrial apparatuses. The main findings of the experiments were as follows: - heat exchange surfaces remained perfectly leak proof; - hydrogen detection in the sodium and argon constitute additional systems for monitoring the impermeability to leaks of a SG with a free sodium surface; - extrapolation of the findings to the SUPER PHENIX SG shows that water leaking at a rate of 100 mg/s would induce in ten minutes a 50% rise of the signal produced by the hydrogen monitoring device in the sodium; - acoustic method can detect leaks of the order of one g/s in a 45 MW SG sited in an industrial environment

  18. Comparison of measurement of 99mTc-MAG3 plasma clearance by single plasma sample and renal uptake ratio

    International Nuclear Information System (INIS)

    Ushijima, Yo; Sugihara, Hiroki; Okuyama, Chio; Okitsu, Sigeyuki; Nii, Takeshi; Nishida, Takuji; Okamoto, Kunio; Maeda, Tomoho

    1997-01-01

    Measurement of 99m Tc-MAG 3 plasma clearance based on one-compartment model (MPC method) is a non-invasive method using the renal uptake ratio. We evaluated the clinical usefulness of this method, compared with effective renal plasma flow (ERPF) using 123 I-OIH and two single-plasma sample methods using 99m Tc-MAG 3 (Russell method and Bubeck method). The ratio of 99m Tc-MAG 3 clearance to ERPF was 1.00±0.26. MPC method correlated well with Russell and Bubeck methods (r=0.904, r=0.897). We conclude that MPC method is a suitable replacement for single-plasma sample method in routine clinical use. (author)

  19. Exercise-induced bronchospasm and atopy in Ghana: two surveys ten years apart.

    Directory of Open Access Journals (Sweden)

    Emmanuel O D Addo-Yobo

    2007-02-01

    Full Text Available Asthma and allergic diseases have increased in the developed countries. It is important to determine whether the same trends are occurring in the developing countries in Africa. We aimed to determine the time trend in the prevalence of exercise-induced bronchospasm (EIB and atopic sensitisation over a ten-year period in Ghanaian schoolchildren.Two surveys conducted using the same methodology ten years apart (1993 and 2003 among schoolchildren aged 9-16 years attending urban rich (UR, urban poor (UP, and rural (R schools. Exercise provocation consisted of free running for six minutes. Children were skin tested to mite, cat, and dog allergen. 1,095 children were exercised in 1993 and 1,848 in 2003; 916 were skin tested in 1993 and 1,861 in 2003. The prevalence of EIB increased from 3.1% (95% CI 2.2%-4.3% to 5.2% (4.3%-6.3%; absolute percentage increase 2.1% (95% CI 0.6%-3.5%, p < 0.01; among UR, UP, and R children EIB had approximately doubled from 4.2%, 1.4%, and 2.2% to 8.3%, 3.0% and 3.9% respectively. The prevalence of sensitisation had also doubled from 10.6%, 4.7%, and 4.4% to 20.2%, 10.3%, and 9.9% (UR, UP, and R respectively. Mite sensitisation remained unchanged (5.6% versus 6.4%, but sensitisation to cat and dog increased considerably from 0.7% and 0.3% to 4.6% and 3.1%, respectively. In the multiple logistic regression analysis, sensitisation (odds ratio [OR] 1.77, 95% CI 1.12-2.81, age (OR 0.88, 95% CI 0.79-0.98, school (the risk being was significantly lower in UP and R schools: OR 0.40, 95% CI 0.23-0.68 and OR 0.54, 95% CI 0.34-0.86, respectively and year of the study (OR 1.73, 95% CI 1.13-2.66 remained significant and independent associates of EIB.The prevalence of both EIB and sensitisation has approximately doubled over the ten-year period amongst 9- to 16-year-old Ghanaian children irrespective of location, with both EIB and atopy being more common among the UR than the UP and R children.

  20. Directional emission of single photons from small atomic samples

    DEFF Research Database (Denmark)

    Miroshnychenko, Yevhen; V. Poulsen, Uffe; Mølmer, Klaus

    2013-01-01

    We provide a formalism to describe deterministic emission of single photons with tailored spatial and temporal profiles from a regular array of multi-level atoms. We assume that a single collective excitation is initially shared by all the atoms in a metastable atomic state, and that this state i...... is coupled by a classical laser field to an optically excited state which rapidly decays to the ground atomic state. Our model accounts for the different field polarization components via re-absorption and emission of light by the Zeeman manifold of optically excited states.......We provide a formalism to describe deterministic emission of single photons with tailored spatial and temporal profiles from a regular array of multi-level atoms. We assume that a single collective excitation is initially shared by all the atoms in a metastable atomic state, and that this state...

  1. Patient radiation dose in diagnostic and interventional procedures for intracranial aneurysms: Experience at a single center

    International Nuclear Information System (INIS)

    Chun, Chang Woo; Kim, Bum Soo; Lee, Cheol Hyoun; Ihn, Yon Kwon; Shin, Yong Sam

    2014-01-01

    To assess patient radiation doses during cerebral angiography and embolization of intracranial aneurysms in a large sample size from a single center. We studied a sample of 439 diagnostic and 149 therapeutic procedures for intracranial aneurysms in 480 patients (331 females, 149 males; median age, 57 years; range, 21-88 years), which were performed in 2012 with a biplane unit. Parameters including fluoroscopic time, dose-area product (DAP), and total angiographic image frames were obtained and analyzed. Mean fluoroscopic time, total mean DAP, and total image frames were 12.6 minutes, 136.6 +/- 44.8 Gy-cm 2 , and 251 +/- 49 frames for diagnostic procedures, 52.9 minutes, 226.0 +/- 129.2 Gy-cm 2 , and 241 frames for therapeutic procedures, and 52.2 minutes, 334.5 +/- 184.6 Gy-cm 2 , and 408 frames for when both procedures were performed during the same session. The third quartiles for diagnostic reference levels (DRLs) were 14.0, 61.1, and 66.1 minutes for fluoroscopy time, 154.2, 272.8, and 393.8 Gy-cm 2 for DAP, and 272, 276, and 535 for numbers of image frames in diagnostic, therapeutic, and both procedures in the same session, respectively. The proportions of fluoroscopy in DAP for the procedures were 11.4%, 50.5%, and 36.1%, respectively, for the three groups. The mean DAP for each 3-dimensional rotational angiographic acquisition was 19.2 +/- 3.2 Gy-cm 2 . On average, rotational angiography was used 1.4 +/- 0.6 times/session (range, 1-4; n = 580). Radiation dose in our study as measured by DAP, fluoroscopy time and image frames did not differ significantly from other reported DRL studies for cerebral angiography, and DAP was lower with fewer angiographic image frames for embolization. A national registry of radiation-dose data is a necessary next step to refine the dose reference level.

  2. Testing the accuracy of a Bayesian central-dose model for single-grain OSL, using known-age samples

    DEFF Research Database (Denmark)

    Guerin, Guillaume; Combès, Benoit; Lahaye, Christelle

    2015-01-01

    on multi-grain OSL age estimates, these samples are presumed to have been both well-bleached at burial, and unaffected by mixing after deposition. Two ways of estimating single-grain ages are then compared: the standard approach on the one hand, consisting of applying the Central Age Model to De values...... for well-bleached samples; (ii) dose recovery experiments do not seem to be a very reliable tool to estimate the accuracy of a SAR measurement protocol for age determination....

  3. Transcutaneous electric nerve stimulation (TENS) in dentistry- A review.

    Science.gov (United States)

    Kasat, Vikrant; Gupta, Aditi; Ladda, Ruchi; Kathariya, Mitesh; Saluja, Harish; Farooqui, Anjum-Ara

    2014-12-01

    Transcutaneous electric nerve stimulation (TENS) is a non-pharmacological method which is widely used by medical and paramedical professionals for the management of acute and chronic pain in a variety of conditions. Similarly, it can be utilized for the management of pain during various dental procedures as well as pain due to various conditions affecting maxillofacial region. This review aims to provide an insight into clinical research evidence available for the analgesic and non analgesic uses of TENS in pediatric as well as adult patients related to the field of dentistry. Also, an attempt is made to briefly discuss history of therapeutic electricity, mechanism of action of TENS, components of TENs equipment, types, techniques of administration, advantages and contradictions of TENS. With this we hope to raise awareness among dental fraternity regarding its dental applications thereby increasing its use in dentistry. Key words:Dentistry, pain, TENS.

  4. Mild Wind Series, Minute Steak Event

    Science.gov (United States)

    1992-11-20

    radioactive gas and debris from reaching the atmosphere, thereby complying with the test ban treaty. distance from the source point to the surface was...percent of the active data recorded on film is also important in the event of excessive radioactive release. The weighing of the experiments is arbitrary...in a water-base Polution . S41 ’ The caldera 245 feet In diameter and 17 feet deep formed at +23 minutes (figure 4.2). There was consistent

  5. A novel method for single sample multi-axial nanoindentation of hydrated heterogeneous tissues based on testing great white shark jaws.

    Science.gov (United States)

    Ferrara, Toni L; Boughton, Philip; Slavich, Eve; Wroe, Stephen

    2013-01-01

    Nanomechanical testing methods that are suitable for a range of hydrated tissues are crucial for understanding biological systems. Nanoindentation of tissues can provide valuable insights into biology, tissue engineering and biomimetic design. However, testing hydrated biological samples still remains a significant challenge. Shark jaw cartilage is an ideal substrate for developing a method to test hydrated tissues because it is a unique heterogeneous composite of both mineralized (hard) and non-mineralized (soft) layers and possesses a jaw geometry that is challenging to test mechanically. The aim of this study is to develop a novel method for obtaining multidirectional nanomechanical properties for both layers of jaw cartilage from a single sample, taken from the great white shark (Carcharodon carcharias). A method for obtaining multidirectional data from a single sample is necessary for examining tissue mechanics in this shark because it is a protected species and hence samples may be difficult to obtain. Results show that this method maintains hydration of samples that would otherwise rapidly dehydrate. Our study is the first analysis of nanomechanical properties of great white shark jaw cartilage. Variation in nanomechanical properties were detected in different orthogonal directions for both layers of jaw cartilage in this species. The data further suggest that the mineralized layer of shark jaw cartilage is less stiff than previously posited. Our method allows multidirectional nanomechanical properties to be obtained from a single, small, hydrated heterogeneous sample. Our technique is therefore suitable for use when specimens are rare, valuable or limited in quantity, such as samples obtained from endangered species or pathological tissues. We also outline a method for tip-to-optic calibration that facilitates nanoindentation of soft biological tissues. Our technique may help address the critical need for a nanomechanical testing method that is applicable

  6. A novel method for single sample multi-axial nanoindentation of hydrated heterogeneous tissues based on testing great white shark jaws.

    Directory of Open Access Journals (Sweden)

    Toni L Ferrara

    Full Text Available Nanomechanical testing methods that are suitable for a range of hydrated tissues are crucial for understanding biological systems. Nanoindentation of tissues can provide valuable insights into biology, tissue engineering and biomimetic design. However, testing hydrated biological samples still remains a significant challenge. Shark jaw cartilage is an ideal substrate for developing a method to test hydrated tissues because it is a unique heterogeneous composite of both mineralized (hard and non-mineralized (soft layers and possesses a jaw geometry that is challenging to test mechanically. The aim of this study is to develop a novel method for obtaining multidirectional nanomechanical properties for both layers of jaw cartilage from a single sample, taken from the great white shark (Carcharodon carcharias. A method for obtaining multidirectional data from a single sample is necessary for examining tissue mechanics in this shark because it is a protected species and hence samples may be difficult to obtain. Results show that this method maintains hydration of samples that would otherwise rapidly dehydrate. Our study is the first analysis of nanomechanical properties of great white shark jaw cartilage. Variation in nanomechanical properties were detected in different orthogonal directions for both layers of jaw cartilage in this species. The data further suggest that the mineralized layer of shark jaw cartilage is less stiff than previously posited. Our method allows multidirectional nanomechanical properties to be obtained from a single, small, hydrated heterogeneous sample. Our technique is therefore suitable for use when specimens are rare, valuable or limited in quantity, such as samples obtained from endangered species or pathological tissues. We also outline a method for tip-to-optic calibration that facilitates nanoindentation of soft biological tissues. Our technique may help address the critical need for a nanomechanical testing method

  7. Acute-Phase Inflammatory Response to Single-Bout HIIT and Endurance Training: A Comparative Study

    Directory of Open Access Journals (Sweden)

    Felix Kaspar

    2016-01-01

    Full Text Available Objective. This study compared acute and late effect of single-bout endurance training (ET and high-intensity interval training (HIIT on the plasma levels of four inflammatory cytokines and C-reactive protein and insulin-like growth factor 1. Design. Cohort study with repeated-measures design. Methods. Seven healthy untrained volunteers completed a single bout of ET and HIIT on a cycle ergometer. ET and HIIT sessions were held in random order and at least 7 days apart. Blood was drawn before the interventions and 30 min and 2 days after the training sessions. Plasma samples were analyzed with ELISA for the interleukins (IL, IL-1β, IL-6, and IL-10, monocyte chemoattractant protein-1 (MCP-1, insulin growth factor 1 (IGF-1, and C-reactive protein (CRP. Statistical analysis was with Wilcoxon signed-rank tests. Results. ET led to both a significant acute and long-term inflammatory response with a significant decrease at 30 minutes after exercise in the IL-6/IL-10 ratio (−20%; p=0.047 and a decrease of MCP-1 (−17.9%; p=0.03. Conclusion. This study demonstrates that ET affects the inflammatory response more adversely at 30 minutes after exercise compared to HIIT. However, this is compensated by a significant decrease in MCP-1 at two days associated with a reduced risk of atherosclerosis.

  8. Acute-Phase Inflammatory Response to Single-Bout HIIT and Endurance Training: A Comparative Study

    Science.gov (United States)

    Kaspar, Felix; Jelinek, Herbert F.; Perkins, Steven; Al-Aubaidy, Hayder A.; deJong, Bev; Butkowski, Eugene

    2016-01-01

    Objective. This study compared acute and late effect of single-bout endurance training (ET) and high-intensity interval training (HIIT) on the plasma levels of four inflammatory cytokines and C-reactive protein and insulin-like growth factor 1. Design. Cohort study with repeated-measures design. Methods. Seven healthy untrained volunteers completed a single bout of ET and HIIT on a cycle ergometer. ET and HIIT sessions were held in random order and at least 7 days apart. Blood was drawn before the interventions and 30 min and 2 days after the training sessions. Plasma samples were analyzed with ELISA for the interleukins (IL), IL-1β, IL-6, and IL-10, monocyte chemoattractant protein-1 (MCP-1), insulin growth factor 1 (IGF-1), and C-reactive protein (CRP). Statistical analysis was with Wilcoxon signed-rank tests. Results. ET led to both a significant acute and long-term inflammatory response with a significant decrease at 30 minutes after exercise in the IL-6/IL-10 ratio (−20%; p = 0.047) and a decrease of MCP-1 (−17.9%; p = 0.03). Conclusion. This study demonstrates that ET affects the inflammatory response more adversely at 30 minutes after exercise compared to HIIT. However, this is compensated by a significant decrease in MCP-1 at two days associated with a reduced risk of atherosclerosis. PMID:27212809

  9. Acute-Phase Inflammatory Response to Single-Bout HIIT and Endurance Training: A Comparative Study.

    Science.gov (United States)

    Kaspar, Felix; Jelinek, Herbert F; Perkins, Steven; Al-Aubaidy, Hayder A; deJong, Bev; Butkowski, Eugene

    2016-01-01

    This study compared acute and late effect of single-bout endurance training (ET) and high-intensity interval training (HIIT) on the plasma levels of four inflammatory cytokines and C-reactive protein and insulin-like growth factor 1. Cohort study with repeated-measures design. Seven healthy untrained volunteers completed a single bout of ET and HIIT on a cycle ergometer. ET and HIIT sessions were held in random order and at least 7 days apart. Blood was drawn before the interventions and 30 min and 2 days after the training sessions. Plasma samples were analyzed with ELISA for the interleukins (IL), IL-1β, IL-6, and IL-10, monocyte chemoattractant protein-1 (MCP-1), insulin growth factor 1 (IGF-1), and C-reactive protein (CRP). Statistical analysis was with Wilcoxon signed-rank tests. ET led to both a significant acute and long-term inflammatory response with a significant decrease at 30 minutes after exercise in the IL-6/IL-10 ratio (-20%; p = 0.047) and a decrease of MCP-1 (-17.9%; p = 0.03). This study demonstrates that ET affects the inflammatory response more adversely at 30 minutes after exercise compared to HIIT. However, this is compensated by a significant decrease in MCP-1 at two days associated with a reduced risk of atherosclerosis.

  10. Ten steps to successful software process improvement

    Science.gov (United States)

    Kandt, R. K.

    2003-01-01

    This paper identifies ten steps for managing change that address organizational and cultural issues. Four of these steps are critical, that if not done, will almost guarantee failure. This ten-step program emphasizes the alignment of business goals, change process goals, and the work performed by the employees of an organization.

  11. Molecular detection of eukaryotes in a single human stool sample from Senegal.

    Directory of Open Access Journals (Sweden)

    Ibrahim Hamad

    Full Text Available BACKGROUND: Microbial eukaryotes represent an important component of the human gut microbiome, with different beneficial or harmful roles; some species are commensal or mutualistic, whereas others are opportunistic or parasitic. The diversity of eukaryotes inhabiting humans remains relatively unexplored because of either the low abundance of these organisms in human gut or because they have received limited attention from a whole-community perspective. METHODOLOGY/PRINCIPAL FINDING: In this study, a single fecal sample from a healthy African male was studied using both culture-dependent methods and extended molecular methods targeting the 18S rRNA and ITS sequences. Our results revealed that very few fungi, including Candida spp., Galactomyces spp., and Trichosporon asahii, could be isolated using culture-based methods. In contrast, a relatively a high number of eukaryotic species could be identified in this fecal sample when culture-independent methods based on various primer sets were used. A total of 27 species from one sample were found among the 977 analyzed clones. The clone libraries were dominated by fungi (716 clones/977, 73.3%, corresponding to 16 different species. In addition, 187 sequences out of 977 (19.2% corresponded to 9 different species of plants; 59 sequences (6% belonged to other micro-eukaryotes in the gut, including Entamoeba hartmanni and Blastocystis sp; and only 15 clones/977 (1.5% were related to human 18S rRNA sequences. CONCLUSION: Our results revealed a complex eukaryotic community in the volunteer's gut, with fungi being the most abundant species in the stool sample. Larger investigations are needed to assess the generality of these results and to understand their roles in human health and disease.

  12. Comparison of skin anesthetic effect of liposomal lidocaine, nonliposomal lidocaine, and EMLA using 30-minute application time.

    Science.gov (United States)

    Bucalo, B D; Mirikitani, E J; Moy, R L

    1998-05-01

    testing was performed at 0, 15, 30, 60, and 90 minutes following the end of the 30-minute application period. Patients' responses to the pinprick were recorded in a binary fashion, as being either: 1) totally painless or 0) painfully sharp to any degree. Ten applications of the pinprick were applied randomly across each 2 x 2-cm test area. The number of painless applications of the pinprick out of a total of 10 applications of the pinprick was then recorded for each test area at every particular test time. In total, nine test preparations were evaluated. Analysis of the data was performed by a PhD statistical faculty consultant from the UCLA Mathematics Department. Liposomal lidocaine preparations evidenced longer durations of anesthesia than lidocaine preparations in nonliposomal vehicles. Five percent liposomal lidocaine preparations were statistically equivalent to EMLA in anesthetic effectiveness. Five percent liposomal lidocaine is an effective alternative topical agent for use in the attainment of temporary local anesthesia of the skin.

  13. 2006 - 2016: Ten Years Of Tsunami In French Polynesia

    Science.gov (United States)

    Reymond, D.; Jamelot, A.; Hyvernaud, O.

    2016-12-01

    Located in South central Pacific and despite of its far field situation, the French Polynesia is very much concerned by the tsunamis generated along the major subduction zones located around the Pacific. At the time of writing, 10 tsunamis have been generated in the Pacific Ocean since 2006; all these events recorded in French Polynesia, produced different levels of warning, starting from a simple seismic warning with an information bulletin, up to an effective tsunami warning with evacuation of the coastal zone. These tsunamigenic events represent an invaluable opportunity of evolutions and tests of the tsunami warning system developed in French Polynesia: during the last ten years, the warning rules had evolved from a simple criterion of magnitudes up to the computation of the main seismic source parameters (location, slowness determinant (Newman & Okal, 1998) and focal geometry) using two independent methods: the first one uses an inversion of W-phases (Kanamori & Rivera, 2012) and the second one performs an inversion of long period surface waves (Clément & Reymond, 2014); the source parameters such estimated allow to compute in near real time the expected distributions of tsunami heights (with the help of a super-computer and parallelized codes of numerical simulations). Furthermore, two kinds of numerical modeling are used: the first one, very rapid (performed in about 5minutes of computation time) is based on the Green's law (Jamelot & Reymond, 2015), and a more detailed and precise one that uses classical numerical simulations through nested grids (about 45 minutes of computation time). Consequently, the criteria of tsunami warning are presently based on the expected tsunami heights in the different archipelagos and islands of French Polynesia. This major evolution allows to differentiate and use different levels of warning for the different archipelagos,working in tandem with the Civil Defense. We present the comparison of the historical observed tsunami

  14. Tank 241-C-111 headspace gas and vapor sample results - August 1993 samples

    International Nuclear Information System (INIS)

    Huckaby, J.L.

    1994-01-01

    Tank 241-C-111 is on the ferrocyanide Watch List. Gas and vapor samples were collected to assure safe conditions before planned intrusive work was performed. Sample analyses showed that hydrogen is about ten times higher in the tank headspace than in ambient air. Nitrous oxide is about sixty times higher than ambient levels. The hydrogen cyanide concentration was below 0.04 ppbv, and the average NO x concentration was 8.6 ppmv

  15. A multi-probe thermophoretic soot sampling system for high-pressure diffusion flames

    Energy Technology Data Exchange (ETDEWEB)

    Vargas, Alex M.; Gülder, Ömer L. [Institute for Aerospace Studies, University of Toronto, Toronto, Ontario M3H 5T6 (Canada)

    2016-05-15

    Optical diagnostics and physical probing of the soot processes in high pressure combustion pose challenges that are not faced in atmospheric flames. One of the preferred methods of studying soot in atmospheric flames is in situ thermophoretic sampling followed by transmission electron microscopy imaging and analysis for soot sizing and morphology. The application of this method of sampling to high pressures has been held back by various operational and mechanical problems. In this work, we describe a rotating disk multi-probe thermophoretic soot sampling system, driven by a microstepping stepper motor, fitted into a high-pressure chamber capable of producing sooting laminar diffusion flames up to 100 atm. Innovative aspects of the sampling system design include an easy and precise control of the sampling time down to 2.6 ms, avoidance of the drawbacks of the pneumatic drivers used in conventional thermophoretic sampling systems, and the capability to collect ten consecutive samples in a single experimental run. Proof of principle experiments were performed using this system in a laminar diffusion flame of methane, and primary soot diameter distributions at various pressures up to 10 atm were determined. High-speed images of the flame during thermophoretic sampling were recorded to assess the influence of probe intrusion on the flow field of the flame.

  16. Value of TENS for relief of chronic low back pain with or without radicular pain.

    Science.gov (United States)

    Buchmuller, A; Navez, M; Milletre-Bernardin, M; Pouplin, S; Presles, E; Lantéri-Minet, M; Tardy, B; Laurent, B; Camdessanché, J P

    2012-05-01

    To evaluate the efficacy of transcutaneous electrical neurostimulation (TENS) in patients with chronic low back pain (LBP). Prospective, randomized, multicentre, single-blind study. Twenty-one French pain centres. Two hundred thirty-six consecutive adult patients consulting for chronic LBP, with or without radicular pain (mean age ± standard deviation: 53 ± 13 years; range: 28-86 years). Patients were randomly assigned to receive either active (n = 117) or sham (n = 119) TENS in four 1-h daily treatment sessions for 3 months. The primary outcome measured was improvement of functional status at 6 weeks (Roland-Morris Disability Questionnaire). Secondary outcome measures were improvement of functional status at 3 months, pain relief (weekly visual analogue scale assessments), positive functional repercussions of pain levels on quality of life, a diminution of the use of analgesic and anti-inflammatory medication, satisfaction with the overall treatment strategy and compliance. Functional status did not differ between the groups, whether at 6 weeks or 3 months (p = 0.351 at 6 weeks). A significant improvement between the first and last visual analogue scale assessments was observed in patients with either lumbar pain alone or lumbar and radicular pain treated with active TENS. Other outcome measures did not differ significantly between the two groups. There was no functional benefit of TENS in the treatment of patients with chronic LBP. © 2011 European Federation of International Association for the Study of Pain Chapters.

  17. rCBF measurement by one-point venous sampling with the ARG method

    International Nuclear Information System (INIS)

    Yoshida, Nobuhiro; Okamoto, Toshiaki; Takahashi, Hidekado; Hattori, Teruo

    1997-01-01

    We investigated the possibility of using venous blood sampling instead of arterial blood sampling for the current method of ARG (autoradiography) used to determine regional cerebral blood flow (rCBF) on the basis of one session of arterial blood sampling and SPECT. For this purpose, the ratio of the arterial blood radioactivity count to the venous blood radioactivity count, the coefficient of variation, and the correlation and differences between arterial blood-based rCBF and venous blood-based rCBF were analyzed. The coefficient of variation was lowest (4.1%) 20 minutes after injection into the dorsum manus. When the relationship between venous and arterial blood counts was analyzed, arterial blood counts correlated well with venous blood counts collected at the dorsum manus 20 or 30 minutes after intravenous injection and with venous blood counts collected at the wrist 20 minutes after intravenous injection (r=0.97 or higher). The difference from rCBF determined on the basis of arterial blood was smallest (0.7) for rCBF determined on the basis of venous blood collected at the dorsum manus 20 minutes after intravenous injection. (author)

  18. Ten major trends now emerging in the United States

    Energy Technology Data Exchange (ETDEWEB)

    Naisbitt, J.

    1978-01-01

    Using a special analytical procedure for tracking and assessing events reported in the nation's newspapers, the Center for Policy Process has identified ten emerging trends in the United States that are having a major impact on all our lives and on all businesses and industries--and especially on the electric utility industry. Although the trends may move in contradictory directions and have different degrees of significance, all have been carefully monitored for a considerable length of time. All are firmly established--and are not to be viewed as the momentary interests of certain radical elements of the population. The ten trends are: the fast-emerging clash between nuclear fuel and coal as an environmental health issue; displacement of racism and sexism by ''ageism'' as society's most prominent anti-discrimination preoccupation, and the complete elimination soon of mandatory retirement; in government and technology, the phenomenon of ''appropriate scale'' replacing economies of scale, emergence of single-issue political organizations; coming-of-age of the recycling ethic; emergence of ''access to capital'' as the new equity issue--the new rights issue; continuing shift from centralization to decentralization; movement of society in the dual directions of high technology/high touch; business' increasing involvement with the well-established accountability trend; and shift from a representative democracy to a participatory democracy--this profound change in American democracy actually began about a decade or so ago.

  19. Reliable single cell array CGH for clinical samples.

    Directory of Open Access Journals (Sweden)

    Zbigniew T Czyż

    Full Text Available BACKGROUND: Disseminated cancer cells (DCCs and circulating tumor cells (CTCs are extremely rare, but comprise the precursors cells of distant metastases or therapy resistant cells. The detailed molecular analysis of these cells may help to identify key events of cancer cell dissemination, metastatic colony formation and systemic therapy escape. METHODOLOGY/PRINCIPAL FINDINGS: Using the Ampli1™ whole genome amplification (WGA technology and high-resolution oligonucleotide aCGH microarrays we optimized conditions for the analysis of structural copy number changes. The protocol presented here enables reliable detection of numerical genomic alterations as small as 0.1 Mb in a single cell. Analysis of single cells from well-characterized cell lines and single normal cells confirmed the stringent quantitative nature of the amplification and hybridization protocol. Importantly, fixation and staining procedures used to detect DCCs showed no significant impact on the outcome of the analysis, proving the clinical usability of our method. In a proof-of-principle study we tracked the chromosomal changes of single DCCs over a full course of high-dose chemotherapy treatment by isolating and analyzing DCCs of an individual breast cancer patient at four different time points. CONCLUSIONS/SIGNIFICANCE: The protocol enables detailed genome analysis of DCCs and thereby assessment of the clonal evolution during the natural course of the disease and under selection pressures. The results from an exemplary patient provide evidence that DCCs surviving selective therapeutic conditions may be recruited from a pool of genomically less advanced cells, which display a stable subset of specific genomic alterations.

  20. Sample Preparation and Mounting of Drosophila Embryos for Multiview Light Sheet Microscopy.

    Science.gov (United States)

    Schmied, Christopher; Tomancak, Pavel

    2016-01-01

    Light sheet fluorescent microscopy (LSFM), and in particular its most widespread flavor Selective Plane Illumination Microscopy (SPIM), promises to provide unprecedented insights into developmental dynamics of entire living systems. By combining minimal photo-damage with high imaging speed and sample mounting tailored toward the needs of the specimen, it enables in toto imaging of embryogenesis with high spatial and temporal resolution. Drosophila embryos are particularly well suited for SPIM imaging because the volume of the embryo does not change from the single cell embryo to the hatching larva. SPIM microscopes can therefore image Drosophila embryos embedded in rigid media, such as agarose, from multiple angles every few minutes from the blastoderm stage until hatching. Here, we describe sample mounting strategies to achieve such a recording. We also provide detailed protocols to realize multiview, long-term, time-lapse recording of Drosophila embryos expressing fluorescent markers on the commercially available Zeiss Lightsheet Z.1 microscope and the OpenSPIM.

  1. Development of a Single-Sampling Noninvasive Hair Snare

    DEFF Research Database (Denmark)

    Bremner-Harrison, Samantha; Harrison, Stephen W. R.; Cypher, Brian L.

    2006-01-01

    Noninvasive hair and fecal DNA sampling provides a means of collecting information on elusive species, while causing little or no disturbance. However, current methods of hair collection do not preclude multiple sampling, thus risking sample contamination. We developed a hair snare that prevents...... multiple sampling, is cost-effective, easy to construct, and safe for target and nontarget species. Our initial field tests on endangered San Joaquin kit foxes (Vulpes macrotis mutica) and swift foxes (Vulpes velox) suggest that this hair snare may be effective in collecting uncontaminated samples for DNA...

  2. Comparison of air samples, nasal swabs, ear-skin swabs and environmental dust samples for detection of Methicillin Resistant Staphylococcus aureus (MRSA) in pig herds

    DEFF Research Database (Denmark)

    Agersø, Yvonne; Vigre, Håkan; Cavaco, Lina

    2014-01-01

    To identify a cost-effective and practical method for detection of methicillin-resistant Staphylococcus aureus (MRSA) in pig herds, the relative sensitivity of four sample types: nasal swabs, ear-skin (skin behind the ears) swabs, environmental dust swabs and air was compared. Moreover, dependency......-herd prevalence ⩾25%]. The results indicate that taking swabs of skin behind the ears (ten pools of five) was even more sensitive than taking nasal swabs (ten pools of five) at the herd level and detected significantly more positive samples. spa types t011, t034 and t4208 were observed. In conclusion, MRSA...... detection by air sampling is easy to perform, reduces costs and analytical time compared to existing methods, and is recommended for initial testing of herds. Ear-skin swab sampling may be more sensitive for MRSA detection than air sampling or nasal swab sampling....

  3. Determination of phosphorus and calcium in biological samples by activation with 14 MeV neutrons

    International Nuclear Information System (INIS)

    Berretta, Jose Roberto

    1995-01-01

    Analytical methods for phosphorus and calcium in biological samples by means of activation with 14 MeV neutrons, using the Van de Graaff accelerator from the Instituto de Pesquisas Energeticas e Nucleares, SP, Brazil are developed. For phosphorus analysis, powder samples were pressed into pellets, weighed and transferred to polyethylene plastic envelopes. The pellets with cadmium shielding were irradiated under a fast neutron flux for 5 to 10 minutes, and further counted in a HPGe detector for 5 minutes. Calcium analysis was performed by cyclic irradiation. Samples were irradiated for 10 minutes. After a decay time of 2 minutes, gamma counting was performed for 10 minutes. After a decay time of 2 minutes, a new irradiation ws made. The irradiation cycle was repeated 5 times and the counting spectrum obtained in each cycle was accumulated in the multi channel analyser. The variation of the neutron flux was followed by using a BF 3 detector calibrated with and aluminium monitor. By means of the gamma spectrum and the neutron counting of the BF 3 detector it was possible to estimate phosphorus and calcium concentrations in the sample analyzed. The methods were checked in the reference samples from the International Atomic Energy Agency and in commercial samples of powder milk, fertilizer and animal bone. Phosphorus contents in bone (A3/74) and milk (A-11) reference materials were (15.6 +- 1.8%) and (0.9 +- 0.1)%, respectively. These values are in good agreement to the certified values (15.5 +- 0.5)% and (0.910 +- 0.102)%, respectively. Calcium analysis carried out in bone (A3/74) presented a value of (31.8+-4.1)% and the certified value was of (31.3 +- 0.3)%. Detection limits for phosphorus and calcium were determined in different analyzed samples. The agreement of the results obtained with the certified values confirmed the suitability of the methods for phosphorus and calcium analysis. The methods are fast and laborious chemical procedures are not required. (author)

  4. USGS 1:24000 (7 1/2 Minute) Quadrangle Index

    Data.gov (United States)

    Minnesota Department of Natural Resources — Mathematically generated grid representing USGS 7 1/2 Minute Quadrangle Map outlines. Quadrangle names and standard identifiers are included with the data set.

  5. Creation of short microwave ablation zones: in vivo characterization of single and paired modified triaxial antennas.

    Science.gov (United States)

    Lubner, Meghan G; Ziemlewicz, Tim J; Hinshaw, J Louis; Lee, Fred T; Sampson, Lisa A; Brace, Christopher L

    2014-10-01

    To characterize modified triaxial microwave antennas configured to produce short ablation zones. Fifty single-antenna and 27 paired-antenna hepatic ablations were performed in domestic swine (N = 11) with 17-gauge gas-cooled modified triaxial antennas powered at 65 W from a 2.45-GHz generator. Single-antenna ablations were performed at 2 (n = 16), 5 (n = 21), and 10 (n = 13) minutes. Paired-antenna ablations were performed at 1-cm and 2-cm spacing for 5 (n = 7 and n = 8, respectively) and 10 minutes (n = 7 and n = 5, respectively). Mean transverse width, length, and aspect ratio of sectioned ablation zones were measured and compared. For single antennas, mean ablation zone lengths were 2.9 cm ± 0.45, 3.5 cm ± 0.55, and 4.2 cm ± 0.40 at 2, 5, and 10 minutes, respectively. Mean widths were 1.8 cm ± 0.3, 2.0 cm ± 0.32, and 2.5 cm ± 0.25 at 2, 5, and 10 minutes, respectively. For paired antennas, mean length at 5 minutes with 1-cm and 2-cm spacing and 10 minutes with 1-cm and 2-cm spacing was 4.2 cm ± 0.9, 4.9 cm ± 1.0, 4.8 cm ± 0.5, and 4.8 cm ± 1.3, respectively. Mean width was 3.1 cm ± 1.0, 4.4 cm ± 0.7, 3.8 cm ± 0.4, and 4.5 cm ± 0.7, respectively. Paired-antenna ablations were more spherical (aspect ratios, 0.72-0.79 for 5-10 min) than single-antenna ablations (aspect ratios, 0.57-0.59). For paired-antenna ablations, 1-cm spacing appeared optimal, with improved circularity and decreased clefting compared with 2-cm spacing (circularity, 0.85 at 1 cm, 0.78 at 2 cm). Modified triaxial antennas can generate relatively short, spherical ablation zones. Paired-antenna ablations were rounder and larger in transverse dimension than single antenna ablations, with 1-cm spacing optimal for confluence of the ablation zone. Copyright © 2014 SIR. Published by Elsevier Inc. All rights reserved.

  6. The origin of the future ten questions for the next ten years

    CERN Document Server

    Gribbin, John

    2006-01-01

    How did the universe begin? Where do galaxies come from? How do stars and planets form? Where do the material particles we are made of come from? How did life begin? Today we have only provisional answers to such questions. But scientific progress will improve these answers dramatically over the next ten years, predicts John Gribbin in this riveting book. He focuses on what we know—or think we know—about ten controversial, unanswered issues in the physical sciences and explains how current cutting-edge research may yield solutions in the very near future. With his trademark facility for engaging readers with or without a scientific background, the author explores ideas concerning the creation of the universe, the possibility of other forms of life, and the fate of the expanding cosmos. He examines “theories of everything,” including grand unified theories and string theory, and he discusses the Big Bang theory, the origin of structure and patterns of matter in the galaxies, and dark mass and dark ene...

  7. Drift correction for single-molecule imaging by molecular constraint field, a distance minimum metric

    International Nuclear Information System (INIS)

    Han, Renmin; Wang, Liansan; Xu, Fan; Zhang, Yongdeng; Zhang, Mingshu; Liu, Zhiyong; Ren, Fei; Zhang, Fa

    2015-01-01

    The recent developments of far-field optical microscopy (single molecule imaging techniques) have overcome the diffraction barrier of light and improve image resolution by a factor of ten compared with conventional light microscopy. These techniques utilize the stochastic switching of probe molecules to overcome the diffraction limit and determine the precise localizations of molecules, which often requires a long image acquisition time. However, long acquisition times increase the risk of sample drift. In the case of high resolution microscopy, sample drift would decrease the image resolution. In this paper, we propose a novel metric based on the distance between molecules to solve the drift correction. The proposed metric directly uses the position information of molecules to estimate the frame drift. We also designed an algorithm to implement the metric for the general application of drift correction. There are two advantages of our method: First, because our method does not require space binning of positions of molecules but directly operates on the positions, it is more natural for single molecule imaging techniques. Second, our method can estimate drift with a small number of positions in each temporal bin, which may extend its potential application. The effectiveness of our method has been demonstrated by both simulated data and experiments on single molecular images

  8. The effect of a single dose of morphine on muscle fatigue indices in male rats

    Directory of Open Access Journals (Sweden)

    Sedigheh Amiresmaili

    2016-09-01

    Full Text Available Background and Aim: Endogenous opioids and addictive opiate drugs change many body functions. . Previous studies have referred to the effects of morphine on smooth and pulmonary muscles ., but the  effects of opioids on skeletal muscles is not known well. Thus, the current study aimed at assessing the effect of a single dose of morphine on muscle fatigue in male rats. Materials and Methods: In this experimental study, 40 male Wistar rats weighing 220-270 g were randomly divided into four equal groups: control (the mice were kept in their cages and received food and water, morphine receiving group, fatigue group (the mice in this group were kept running on  a treadmill . for120 minutes at a rate of 20 meters per minute, and morphine plus fatigue group. At the end of the experiments, blood samples were obtained from the corner of their eyes and were sent to the laboratory for measurement of muscle fatigue indexes including lactate dehydrogenase (LDH and creatine phosphokinase (CPK. Results: Administration of morphine to the fatigue group decreased running time compared with the control group (P=0.009. Furthermore, administration of morphine to the fatigue group significantly increased serum levels of LDH (P=0.009 and CPK (P=0.008. Conclusion: The present study showed that administration of a single dose of morphine in rats increases muscle fatigue biomarkers (LDH, CPK.

  9. A safety equipment list for rotary mode core sampling systems operation in single shell flammable gas tanks; TOPICAL

    International Nuclear Information System (INIS)

    SMALLEY, J.L.

    1999-01-01

    This document identifies all interim safety equipment to be used for rotary mode core sampling of single-shell flammable gas tanks utilizing Rotary Mode Core Sampling systems (RMCS). This document provides the safety equipment for RMCS trucks HO-68K-4600, HO-68K-4647, trucks three and four respectively, and associated equipment. It is not intended to replace or supersede WHC-SD-WM-SEL-023, (Kelly 1991), or WHC-SD-WM-SEL-032, (Corbett 1994), which classifies 80-68K-4344 and HO-68K-4345 respectively. The term ''safety equipment'' refers to safety class (SC) and safety significant (SS) equipment, where equipment refers to structures, systems and components (SSC's). The identification of safety equipment in this document is based on the credited design safety features and analysis contained in the Authorization Basis (AB) for rotary mode core sampling operations in single-shell flammable gas tanks. This is an interim safety classification since the AB is interim. This document will be updated to reflect the final RMCS equipment safety classification designations upon completion of a final AB which will be implemented with the release of the Final Safety Analysis Report (FSAR)

  10. Transcutaneous electrical nerve stimulation (TENS) for chronic low back pain.

    Science.gov (United States)

    Milne, S; Welch, V; Brosseau, L; Saginur, M; Shea, B; Tugwell, P; Wells, G

    2001-01-01

    Low back pain (LBP) affects a large proportion of the population. Transcutaneous electrical nerve stimulation (TENS) was introduced more than 30 years ago as an alternative therapy to pharmacological treatments for chronic pain. However, despite its widespread use, the effectiveness of TENS is still controversial. The aim of this systematic review was to determine the efficacy of TENS in the treatment of chronic LBP. We searched MEDLINE, EMBASE, PEDro and the Cochrane Controlled Trials Register up to June 1, 2000. Only randomized controlled clinical trials of TENS for the treatment of patients with a clinical diagnosis of chronic LBP were included. Abstracts were excluded unless further data could be obtained from the authors. Two reviewers independently selected trials and extracted data using predetermined forms. Heterogeneity was tested with Cochran's Q test. A fixed effects model was used throughout for continuous variables, except where heterogeneity existed, in which case, a random effects model was used. Results are presented as weighted mean differences (WMD) with 95% confidence intervals (95% CI), where the difference between the treated and control groups was weighted by the inverse of the variance. Standardized mean differences (SMD) were calculated by dividing the difference between the treated and control by the baseline variance. SMD were used when different scales were used to measure the same concept. Dichotomous outcomes were analyzed with odds ratios. Five trials were included, with 170 subjects randomized to the placebo group receiving sham-TENS and 251 subjects receiving active TENS (153 for conventional mode, 98 for acupuncture-like TENS). The schedule of treatments varied greatly between studies ranging from one treatment/day for two consecutive days, to three treatments/day for four weeks. There were no statistically significant differences between the active TENS group when compared to the placebo TENS group for any outcome measures

  11. Single scrotal incision orchidopexy for palpable undescended

    International Nuclear Information System (INIS)

    Ahmad, A.; Safdar, C.A.; Yasir, U.; Rasool, N.; Kanwal, S.; Boota, M.; Rehman, J.U.

    2014-01-01

    To retrospectively asses the results of single scrotal incision orchidopexy (SSIO) performed at our centre with ligation of the patent processus vaginalis in children having palpable undescended testes (UDT). Study Design: Quasi-experimental with retrospective data. Place and Duration of Study: Department of Paediatric surgery Military Hospital Rawalpindi, from April 2007 to December 2011. Patients and Methods: After making a single transverse incision at superior scrotal border, the testis was identified; gubernaculums and the sac were dissected to the highest level and divided. The testis was placed into the scrotum and fixed to the scrotal fascia/skin. All patients were assessed at 2 weeks, 2 months and 6 months post operatively, and then yearly. Results: A total of 38 orchidopexies were performed in 33 patients. The patients age ranged from 14 months to 7 years (mean:2.1 years). Bilateral UDT were found in 5 patients (15.1%). Operative time ranged from 20 to 45 minutes (mean: 36 minutes). The single scrotal incision technique was successful in all 38 cases (100%). All testes were easily fixed in the scrotum. Two patients (5.2%) developed scrotal haematoma and one patient (2.6%) developed stitch abscess. All showed good an atomical and cosmetic results up to a minimum of six months of follow-up. Conclusion: Single scrotal incision orchidopexy for palpable undescended testis is a simple and safe technique. It has shown to consume shorter time and give good cosmetic results. (author)

  12. Single-layer centrifugation through colloid selects improved quality of epididymal cat sperm.

    Science.gov (United States)

    Chatdarong, K; Thuwanut, P; Morrell, J M

    2010-06-01

    The objectives were to determine the: 1) extent of epithelial and red blood cell contamination in epididymal cat sperm samples recovered by the cutting method; 2) efficacy of simple washing, single-layer centrifugation (SLC), and swim-up for selecting epididymal cat sperm; and 3) effects of freezing and thawing on cat sperm selected by various techniques. Ten unit samples were studied; each contained sperm from the cauda epididymides of four cats (total, approximately 200 x 10(6) sperm) and was equally allocated into four treatments: 1) simple washing, 2) single-layer centrifugation through colloid prior to cryopreservation (SLC-PC), 3) single-layer centrifugation through colloid after cryopreservation (SLC-AC), and 4) swim-up. Centrifugation (300 x g for 20 min) was done for all methods. The SLC-PC had a better recovery rate than the SLC-AC and swim-up methods (mean+/-SD of 16.4+/-8.7, 10.7+/-8.9, and 2.3+/-1.7%, respectively; Pblood cell contamination than simple washed samples (0.02+/-0.01, 0.02+/-0.04, 0.03+/-0.04, and 0.44+/-0.22 x 10(6) cells/mL, respectively; P0.05), SLC-PC yielded the highest percentage of sperm with normal midpieces and tails (P0.05). In conclusion, both SLC-PC and swim-up improved the quality of epididymal cat sperm, including better morphology, membrane and DNA integrity, and removal of cellular contamination. However, SLC had a better sperm recovery rate than swim-up. 2010 Elsevier Inc. All rights reserved.

  13. Pharmacokinetics after oral and intravenous administration of a single dose of tramadol hydrochloride to Hispaniolan Amazon parrots (Amazona ventralis).

    Science.gov (United States)

    Souza, Marcy J; Sanchez-Migallon Guzman, David; Paul-Murphy, Joanne R; Cox, Sherry K

    2012-08-01

    To determine pharmacokinetics after IV and oral administration of a single dose of tramadol hydrochloride to Hispaniolan Amazon parrots (Amazona ventralis). 9 healthy adult Hispaniolan Amazon parrots (3 males, 5 females, and 1 of unknown sex). Tramadol (5 mg/kg, IV) was administered to the parrots. Blood samples were collected from -5 to 720 minutes after administration. After a 3-week washout period, tramadol (10 and 30 mg/kg) was orally administered to parrots. Blood samples were collected from -5 to 1,440 minutes after administration. Three formulations of oral suspension (crushed tablets in a commercially available suspension agent, crushed tablets in sterile water, and chemical-grade powder in sterile water) were evaluated. Plasma concentrations of tramadol and its major metabolites were measured via high-performance liquid chromatography. Mean plasma tramadol concentrations were > 100 ng/mL for approximately 2 to 4 hours after IV administration of tramadol. Plasma concentrations after oral administration of tramadol at a dose of 10 mg/kg were 100 ng/mL for approximately 6 hours after administration. Oral administration of the suspension consisting of the chemical-grade powder resulted in higher plasma tramadol concentrations than concentrations obtained after oral administration of the other 2 formulations; however, concentrations differed significantly only at 120 and 240 minutes after administration. Oral administration of tramadol at a dose of 30 mg/kg resulted in plasma concentrations (> 100 ng/mL) that have been associated with analgesia in Hispaniolan Amazon parrots.

  14. A Randomized Controlled Trial of Auricular Transcutaneous Electrical Nerve Stimulation for Managing Posthysterectomy Pain

    Directory of Open Access Journals (Sweden)

    Hin Cheung Tsang

    2011-01-01

    Result. As compared to the baseline, only the true TENS group reported a significant reduction in VAS-rest (P=.001, VAS-huff (P=.004, and VAS-cough (P=.001, while no significant reduction in any of the VAS scores was seen in the sham TENS group (all P>.05. In contrast, a small rising trend was observed in the VAS-rest and VAS-huff scores of the control group, while the VAS-cough score remained largely unchanged during the period of the study. A between-group comparison revealed that all three VAS scores of the true TENS group were significantly lower than those of the control group at 15 and 30 minutes after the intervention (all P<.02. No significant between-group difference was observed in PEFR at any point in time. Conclusion. A single session of auricular TENS applied at specific therapeutic points significantly reduced resting (VAS-rest and movement-evoked pain (VAS-huff, VAS-cough, and the effects lasted for at least 30 minutes after the stimulation. The analgesic effects of auricular TENS appeared to be point specific and could not be attributed to the placebo effect alone. However, auricular TENS did not produce any significant improvement in the performance of PEFR.

  15. Reliability of a single objective measure in assessing sleepiness.

    Science.gov (United States)

    Sunwoo, Bernie Y; Jackson, Nicholas; Maislin, Greg; Gurubhagavatula, Indira; George, Charles F; Pack, Allan I

    2012-01-01

    To evaluate reliability of single objective tests in assessing sleepiness. Subjects who completed polysomnography underwent a 4-nap multiple sleep latency test (MSLT) the following day. Prior to each nap opportunity on MSLT, subjects performed the psychomotor vigilance test (PVT) and divided attention driving task (DADT). Results of single versus multiple test administrations were compared using the intraclass correlation coefficient (ICC) and adjusted for test administration order effects to explore time of day effects. Measures were explored as continuous and binary (i.e., impaired or not impaired). Community-based sample evaluated at a tertiary, university-based sleep center. 372 adult commercial vehicle operators oversampled for increased obstructive sleep apnea risk. N/A. AS CONTINUOUS MEASURES, ICC WERE AS FOLLOWS: MSLT 0.45, PVT median response time 0.69, PVT number of lapses 0.51, 10-min DADT tracking error 0.87, 20-min DADT tracking error 0.90. Based on binary outcomes, ICC were: MSLT 0.63, PVT number of lapses 0.85, 10-min DADT 0.95, 20-min DADT 0.96. Statistically significant time of day effects were seen in both the MSLT and PVT but not the DADT. Correlation between ESS and different objective tests was strongest for MSLT, range [-0.270 to -0.195] and persisted across all time points. Single DADT and PVT administrations are reliable measures of sleepiness. A single MSLT administration can reasonably discriminate individuals with MSL < 8 minutes. These results support the use of a single administration of some objective tests of sleepiness when performed under controlled conditions in routine clinical care.

  16. NOS CO-OPS Water Level Data, Preliminary, 6-Minute

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This dataset has recent, preliminary (not quality-controlled), 6-minute, water level (tide) data from NOAA NOS Center for Operational Oceanographic Products and...

  17. NOS CO-OPS Water Level Data, Preliminary, 1-Minute

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This dataset has recent, preliminary (not quality-controlled), 1-minute, water level (tide) data from NOAA NOS Center for Operational Oceanographic Products and...

  18. Single visit nonsurgical endodontic therapy for periapical cysts: A clinical study.

    Science.gov (United States)

    Maity, Ipsita; Meena, N; Kumari, R Anitha

    2014-04-01

    The aim of this study was to assess the outcome of single sitting root canal treatment (RCT) of asymptomatic teeth with periapical cysts. Ten maxillary anterior teeth showing periapical lesion on the radiograph was further screened by ultrasound with color power Doppler (CPD) for confirmation of a cyst. The average dimension of the lesions ranged from 1.3 to 1.9 cm. Single sitting RCT was performed on all the selected teeth. Postoperative healing was monitored at regular interval of 3 months, 6 months, and 1 year by using subjective feedback, radiograph, and ultrasound with CPD study. Eight among the ten cases showed either signs of complete healing or healing in progress by the end of 6-12 months. It was observed that single sitting nonsurgical endodontic management of asymptomatic teeth with periapical cyst confirmed by ultrasound was successful in selected cases.

  19. A Ten-Year Reflection

    Science.gov (United States)

    Phillip, Cyndi

    2016-01-01

    Five initiatives launched during Cyndi Phillip's term as American Association of School Librarians (AASL) President (2006-2007) continue to have an impact on school librarians ten years later. They include the rewriting of AASL's learning standards, introduction of the SKILLS Act, the presentation of the Crystal Apple Award to Scholastic Library…

  20. The effects of Transcutaneous Electrical Nerve Stimulation on postural control in patients with chronic low back pain.

    Science.gov (United States)

    Rojhani-Shirazi, Z; Rezaeian, T

    2015-01-01

    Objective: The effects of transcutaneous electrical nerve stimulation (TENS) on postural control in patients with low back pain which is not well known. This study aimed to evaluate the effects of TENS on postural control in chronic low back pain. Methods: This study was an experimental research design. Twenty-eight patients with chronic LBP (25-45 Y/ O) participated and by using a random allocation, were divided to samples who participated in this study. The mean center of pressure (COP) velocity and displacement were measured before, immediately and 30 min after the intervention. The tests were done with eyes open and closed on a force platform. Sensory electrical stimulation was applied through the TENS device. The descriptive statistics, independent sample T-test and ANOVA with repeated measurement on time were used for data analysis. Results: The results of the present study demonstrated that the application of the sensory electrical stimulation in chronic LBP patients showed a statistically significant improvement in postural control in Medio-lateral direction with no corresponding effect on the anterior-posterior direction immediately following the TENS application and 30 minutes after it in closed eyes conditions as compared to baseline. The application of TENS decreased the displacement and velocity of COP (p≤0.05), 30 minutes after the application of sensory electrical stimulation. The results showed that the mean displacement and velocity of COP decreased in eyes open position (p≤0.05). Also, immediately and 30 minutes after the application of sensory electrical stimulation, COP displacement and velocity in ML direction with eyes closed significantly decreased in the intervention group in comparison with control group (p≤0.05). Conclusion: The application of TENS in patients with chronic low back pain could improve postural control in these patients.

  1. Frequency of single nucleotide polymorphisms of some immune response genes in a population sample from São Paulo, Brazil

    Directory of Open Access Journals (Sweden)

    Léa Campos de Oliveira

    2011-09-01

    Full Text Available Objective: To present the frequency of single nucleotide polymorphismsof a few immune response genes in a population sample from SãoPaulo City (SP, Brazil. Methods: Data on allele frequencies ofknown polymorphisms of innate and acquired immunity genes werepresented, the majority with proven impact on gene function. Datawere gathered from a sample of healthy individuals, non-HLA identicalsiblings of bone marrow transplant recipients from the Hospital dasClínicas da Faculdade de Medicina da Universidade de São Paulo,obtained between 1998 and 2005. The number of samples variedfor each single nucleotide polymorphism analyzed by polymerasechain reaction followed by restriction enzyme cleavage. Results:Allele and genotype distribution of 41 different gene polymorphisms,mostly cytokines, but also including other immune response genes,were presented. Conclusion: We believe that the data presentedhere can be of great value for case-control studies, to define whichpolymorphisms are present in biologically relevant frequencies and toassess targets for therapeutic intervention in polygenic diseases witha component of immune and inflammatory responses.

  2. Large scale exact quantum dynamics calculations: Ten thousand quantum states of acetonitrile

    Science.gov (United States)

    Halverson, Thomas; Poirier, Bill

    2015-03-01

    'Exact' quantum dynamics (EQD) calculations of the vibrational spectrum of acetonitrile (CH3CN) are performed, using two different methods: (1) phase-space-truncated momentum-symmetrized Gaussian basis and (2) correlated truncated harmonic oscillator basis. In both cases, a simple classical phase space picture is used to optimize the selection of individual basis functions-leading to drastic reductions in basis size, in comparison with existing methods. Massive parallelization is also employed. Together, these tools-implemented into a single, easy-to-use computer code-enable a calculation of tens of thousands of vibrational states of CH3CN to an accuracy of 0.001-10 cm-1.

  3. NOS CO-OPS Water Level Data, Verified, 6-Minute

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This dataset has verified (quality-controlled), 6-minute, water level (tide) data from NOAA NOS Center for Operational Oceanographic Products and Services (CO-OPS)....

  4. How could she? Psychosocial analysis of ten homicide cases committed by women.

    Science.gov (United States)

    Hellen, Florence; Lange-Asschenfeldt, Christian; Ritz-Timme, Stefanie; Verhülsdonk, Sandra; Hartung, Benno

    2015-11-01

    Ten percent of all homicide perpetrators are female and homicidal acts committed by women are mostly a result of interpersonal conflicts. We carried out a retrospective psychosocial analysis of ten homicide cases committed by women with an urban mid-European background. We evaluated characteristic determinants regarding 1) deed circumstances and motives, 2) the perpetrators, and 3) the victims. Results were compared with the literature on female and male homicides. Autopsy records of the Institute of Legal Medicine of the University Hospital of Düsseldorf, Germany, during the time period from 2006 to 2011 were searched for homicides committed by female perpetrators. Prosecution files were reviewed for further information. The sample comprised N = 10 female homicide perpetrators and eleven victims. The mentioned determinants of the homicide were fairly consistent. All deeds occurred in the domestic context; they were mostly unplanned. All perpetrators were socially isolated and faced socially challenging situations. Most perpetrators were of low socioeconomic status. Furthermore, all victims were helpless and/or dependent on the perpetrator. The presence of a major psychiatric disorder was uncommon and, in contrast to male perpetrators, most women had no previous convictions. The potential value of these core findings in our sample regarding prevention is discussed. Copyright © 2015 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  5. Pressure-assisted electrokinetic injection for on-line enrichment in capillary electrophoresis-mass spectrometry: a sensitive method for measurement of ten haloacetic acids in drinking water.

    Science.gov (United States)

    Zhang, Huijuan; Zhu, Jiping; Aranda-Rodriguez, Rocio; Feng, Yong-Lai

    2011-11-07

    Haloacetic acids (HAAs) are by-products of the chlorination of drinking water containing natural organic matter and bromide. A simple and sensitive method has been developed for determination of ten HAAs in drinking water. The pressure-assisted electrokinetic injection (PAEKI), an on-line enrichment technique, was employed to introduce the sample into a capillary electrophoresis (CE)-electrospray ionization-tandem mass spectrometry system (ESI-MS/MS). HAAs were monitored in selected reaction monitoring mode. With 3 min of PAEKI time, the ten major HAAs (HAA10) in drinking water were enriched up to 20,000-fold into the capillary without compromising resolution. A simple solid phase clean-up method has been developed to eliminate the influence of ionic matrices from drinking water on PAEKI. Under conditions optimized for mass spectrometry, PAEKI and capillary electrophoresis, detection limits defined as three times ratio of signal to noise have been achieved in a range of 0.013-0.12 μg L(-1) for ten HAAs in water sample. The overall recoveries for all ten HAAs in drinking water samples were between 76 and 125%. Six HAAs including monochloro- (MCAA), dichloro- (DCAA), trichloro- (TCAA), monobromo- (MBAA), bromochloro- (BCAA), and bromodichloroacetic acids (BDCAA) were found in tap water samples collected. Crown Copyright © 2011. Published by Elsevier B.V. All rights reserved.

  6. The Effectiveness of MURDER Cooperative Model towards Students' Mathematics Reasoning Ability and Self Concept of Ten Grade

    Directory of Open Access Journals (Sweden)

    Sofan Tri Prasetiyo

    2017-08-01

    Full Text Available The purpose of this research was to know the effectiveness of MURDER cooperative model towards students’ mathematics reasoning ability and self concept of ten grade. Population of this research were students of MIA ten grade Senior High School 1 Kebumen in the academic year 2016/1017. Sampling technique using simple random sampling technique. The data collected by the method of documentation, test methods, observation methods, and questionnaire methods. The analyzed of data are used completeness test and average different test. The results showed that: (1 mathematics reasoning ability of students that following MURDER cooperative model have completed individual and classical study completeness; (2 mathematics reasoning ability of students that following MURDER cooperative model better than mathematics reasoning ability of students that following ekspository learning; (3 self concept of students that following MURDER cooperative model better than self concept of students that following ekspository learning.

  7. Volatiles from a rare Acer spp. honey sample from Croatia.

    Science.gov (United States)

    Jerković, Igor; Marijanović, Zvonimir; Malenica-Staver, Mladenka; Lusić, Drazen

    2010-06-24

    A rare sample of maple (Acer spp.) honey from Croatia was analysed. Ultrasonic solvent extraction (USE) using: 1) pentane, 2) diethyl ether, 3) a mixture of pentane and diethyl ether (1:2 v/v) and 4) dichloromethane as solvents was applied. All the extracts were analysed by GC and GC/MS. The most representative extracts were 3) and 4). Syringaldehyde was the most striking compound, being dominant in the extracts 2), 3) and 4) with percentages 34.5%, 33.1% and 35.9%, respectively. In comparison to USE results of other single Croatian tree honey samples (Robinia pseudoacacia L. nectar honey, Salix spp. nectar and honeydew honeys, Quercus frainetto Ten. honeydew as well as Abies alba Mill. and Picea abies L. honeydew) and literature data the presence of syringaldehyde, previously identified in maple sap and syrup, can be pointed out as a distinct characteristic of the Acer spp. honey sample. Headspace solid-phase microextraction (HS-SPME) combined with GC and GC/MS identified benzaldehyde (16.5%), trans-linalool oxide (20.5%) and 2-phenylethanol (14.9%) as the major compounds that are common in different honey headspace compositions.

  8. Ten-year survival rates of teeth adjacent to treated and untreated posterior bounded edentulous spaces.

    Science.gov (United States)

    Aquilino, S A; Shugars, D A; Bader, J D; White, B A

    2001-05-01

    Failure to replace a single missing posterior tooth may lead to a variety of dental problems, which may ultimately result in tooth loss. However, little is known about the fate of the adjacent teeth if a missing posterior tooth is not replaced. This retrospective study evaluated the survival of teeth adjacent to treated and untreated posterior bounded edentulous spaces. Data were obtained from electronic treatment records from the Kaiser Permanente Dental Care Program, Portland, Ore. A final sample of 317 patients who met the study inclusion criteria was identified. Each bounded edentulous space was placed in 1 of 3 treatment categories: untreated, restored with a fixed partial denture, or restored with a removable partial denture. Subsequent treatment and the status of the teeth adjacent to the bounded edentulous space were followed through December 1999. Ten-year Kaplan-Meier survival estimates were generated for each treatment group, and differences in survival were evaluated with the log-rank chi-square test (alpha=.05). There was a significant difference in survival among the 3 treatment categories (P=.005). Spaces restored with a fixed partial denture had longer 10-year survival estimates (92%) than those that remained untreated (81%). Spaces restored with a removable partial denture had the poorest 10-year survival rate (56%). Under the conditions and selection bias associated with this retrospective study, the survival of teeth adjacent to a single posterior edentulous space was negatively associated with removable partial denture placement compared with no treatment or the use of a fixed partial denture.

  9. Get 150 minutes/week of moderate physical activity: It doesn’t matter how

    Science.gov (United States)

    Researchers at the National Cancer Institute have shown that people who engage in more minutes of moderate-intensity physical activity enjoy health benefits (measured here by likelihood of dying during the study period), but it does not matter how those minutes are accumulated.

  10. The effects of a single bout pilates exercise on mRNA expression of bone metabolic cytokines in osteopenia women.

    Science.gov (United States)

    Kim, Chang Sun; Kim, Ji Yeon; Kim, Hyo Jin

    2014-03-01

    The purpose of this study was to examine the effect of a single bout pilates exercise on mRNA expression of bone metabolic cytokines in elderly osteopenia women. We selected 11 people of elderly osteopenia women and loaded a single bout pilates exercise about RPE 10-14 level. The blood samples were collected before, immediately after and 60 minute after pilates exercise, then examined calcium metabolic markers in serum and extracted peripheral blood mononuclear cell (PBMC) from whole blood and confirmed mRNA expression of bone metabolic cytokines from PBMC. To clarify the changes during exercise, we designed repeated measure ANOVA as the control group to perform blood sampling without exercise. As a result, serum P showed significant interaction effect between group and time (ppilates exercise group decreased about 9% at immediately after exercise and 13% during recovery after exercise (ppilates group significantly increased at immediately after exercise and during recovery after exercise (ppilates group (ppilates group (NS). These results suggested that a single bout pilates exercise of elderly osteopenia women cause hypophosphatemia with temporary muscle damage, and it leading high turnover bone metabolic state with to activate both of bone formation and bone resorption.

  11. The Benefits of Single-Touch Screens in Intersubjective Meaning Making

    OpenAIRE

    Davidsen, Jacob; Christiansen, Ellen Tove

    2013-01-01

    What are the benefits of single-touch screens? The paper presents findings of onevideo extract from ten months of observation of single-touch screen interaction among 8-9 year-old children. Recent studies of collaborative learning mediated by digital touch screens and tabletops emphasize the possibilities for equal levels of verbal and physical participation.Additionally, these studies suggest that multi-touch technologies offer more task-oriented activities compared to single-touch screen in...

  12. Single-task and dual-task tandem gait test performance after concussion.

    Science.gov (United States)

    Howell, David R; Osternig, Louis R; Chou, Li-Shan

    2017-07-01

    To compare single-task and dual-task tandem gait test performance between athletes after concussion with controls on observer-timed, spatio-temporal, and center-of-mass (COM) balance control measurements. Ten participants (19.0±5.5years) were prospectively identified and completed a tandem gait test protocol within 72h of concussion and again 1 week, 2 weeks, 1 month, and 2 months post-injury. Seven uninjured controls (20.0±4.5years) completed the same protocol in similar time increments. Tandem gait test trials were performed with (dual-task) and without (single-task) concurrently performing a cognitive test as whole-body motion analysis was performed. Outcome variables included test completion time, average tandem gait velocity, cadence, and whole-body COM frontal plane displacement. Concussion participants took significantly longer to complete the dual-task tandem gait test than controls throughout the first 2 weeks post-injury (mean time=16.4 [95% CI: 13.4-19.4] vs. 10.1 [95% CI: 6.4-13.7] seconds; p=0.03). Single-task tandem gait times were significantly lower 72h post-injury (p=0.04). Dual-task cadence was significantly lower for concussion participants than controls (89.5 [95% CI: 68.6-110.4] vs. 127.0 [95% CI: 97.4-156.6] steps/minute; p=0.04). Moderately-high to high correlations between tandem gait test time and whole-body COM medial-lateral displacement were detected at each time point during dual-task gait (r s =0.70-0.93; p=0.03-0.001). Adding a cognitive task during the tandem gait test resulted in longer detectable deficits post-concussion compared to the traditional single-task tandem gait test. As a clinical tool to assess dynamic motor function, tandem gait may assist with return to sport decisions after concussion. Copyright © 2017 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  13. The six-minute walk test in paediatric populations

    NARCIS (Netherlands)

    Janke de Groot

    2011-01-01

    The six-minute walk test (6MWT) is a self-paced, submaximal exercise test used to assess functional exercise capacity in patients with chronic diseases (Chang 2006, Solway et al 2001). It has been used widely in adults, and is being utilised increasingly in paediatric populations; it has been used

  14. Variation in orgasm occurrence by sexual orientation in a sample of U.S. singles.

    Science.gov (United States)

    Garcia, Justin R; Lloyd, Elisabeth A; Wallen, Kim; Fisher, Helen E

    2014-11-01

    Despite recent advances in understanding orgasm variation, little is known about ways in which sexual orientation is associated with men's and women's orgasm occurrence. To assess orgasm occurrence during sexual activity across sexual orientation categories. Data were collected by Internet questionnaire from 6,151 men and women (ages 21-65+ years) as part of a nationally representative sample of single individuals in the United States. Analyses were restricted to a subsample of 2,850 singles (1,497 men, 1,353 women) who had experienced sexual activity in the past 12 months. Participants reported their sex/gender, self-identified sexual orientation (heterosexual, gay/lesbian, bisexual), and what percentage of the time they experience orgasm when having sex with a familiar partner. Mean occurrence rate for experiencing orgasm during sexual activity with a familiar partner was 62.9% among single women and 85.1% among single men, which was significantly different (F1,2848  = 370.6, P sexual orientation: heterosexual men 85.5%, gay men 84.7%, bisexual men 77.6% (F2,1494  = 2.67, P = 0.07, η(2)  = 0.004). For women, however, mean occurrence rate of orgasm varied significantly by sexual orientation: heterosexual women 61.6%, lesbian women 74.7%, bisexual women 58.0% (F2,1350  = 10.95, P sexual orientation, have less predictable, more varied orgasm experiences than do men and that for women, but not men, the likelihood of orgasm varies with sexual orientation. These findings demonstrate the need for further investigations into the comparative sexual experiences and sexual health outcomes of sexual minorities. © 2014 International Society for Sexual Medicine.

  15. Mechanical Working Group meeting minutes

    Energy Technology Data Exchange (ETDEWEB)

    1992-12-01

    This documents contains the minutes and viewgraphs from the October 27--28, 1992 meeting on the subject of power generation and delivery systems for military applications. Attendees represented the US Air Force and NASA. The thermal management panel reported on the capillary pump loop test facility, thermal control systems and compressors, and the oxygen heat pipe flight experiment. The aerospace power panel reported on the integrated power unit for the more electric airplane, the solar dynamic power system, the modular high temperature gas cooled reactor-gas-turbine program, the multi-megawatt CBC power system, and analytical modeling for heat pipe performance. The terrestrial power panel reported on a free piston stirling engine power generation system, fuel cell vehicles, and the advanced gas turbine project.

  16. Scintigraphic demonstration of single- or two-phase gastric emptying in diabetics

    International Nuclear Information System (INIS)

    Eikman, E.A.; Leichter, S.; Waldholtz, B.; Tenorio, L.; Brady, P.

    1989-01-01

    This paper discusses how a modified scintigraphic test of gastric emptying revealed two types of abnormal gastric emptying in diabetic patients. After ingestion of 100 mL of cooked egg whites labeled with 0.5 mCi of Tc-99m sulfur colloid, the geometric mean stomach radioactivity was recorded serially for 90 minutes. Linear regression computed for the log of radioactivity versus time facilitated recognition of changes in gastric emptying. In 16 of 25 consecutive diabetic patients with postprandial symptoms, initial slow emptying (half-life,>100 minutes) was observed. Single-phase emptying was shown in seven of these patients. In nine patients, the slow-emptying phase lasted up to 50 minutes, followed by a distinct second phase of normal or rapid emptying (half-life, <40 minutes). The existence of different gastric emptying implies differing mechanisms of delay and may be important in treatment

  17. MORE MINUTES OF PHYSICAL EDUCATION CLASSES SUPPORT MOTOR DEVELOPMENT IN PRESCHOOL CHILDREN

    Directory of Open Access Journals (Sweden)

    Judith Jiménez Díaz

    2010-12-01

    Full Text Available The aim of this study was to determine the effect of physical education classes in 12 fundamental motor skills (FMS. Preschool students (M = 6.09±0.5 years old were randomly assigned to a control group (6 boys and 7 girls who performed the regular preschool class (which includes one 30- minutes session per week; experimental group 1 (6 boys and 6 girls who received the regular preschool class plus 1 session of 30 minutes per week of the intervention program; or experimental group 2 (6 boys and 7 girls, who received the regular preschool class plus 1 session of 60 minutes per week of the intervention program; during 8 weeks (n=38. All participants performed the Test of Gross Motor Development (TGMD-2 before and after the study. A one-way MANOVA reflected a similar behavior in al FMS in the pre-test. A two-way MANOVA (group x time reflected no interaction in the 12 FMS; also in the 6 object control FMS; but there was an interaction in the 6 locomotor FMS. In conclusion, 90-minutes of physical education classes per week only benefit the FMS of galloping and hopping.

  18. Affordances: Ten Years On

    Science.gov (United States)

    Brown, Jill P.; Stillman, Gloria

    2014-01-01

    Ten years ago the construct, affordance, was rising in prominence in scholarly literature. A proliferation of different uses and meanings was evident. Beginning with its origin in the work of Gibson, we traced its development and use in various scholarly fields. This paper revisits our original question with respect to its utility in mathematics…

  19. Damage evolution analysis of coal samples under cyclic loading based on single-link cluster method

    Science.gov (United States)

    Zhang, Zhibo; Wang, Enyuan; Li, Nan; Li, Xuelong; Wang, Xiaoran; Li, Zhonghui

    2018-05-01

    In this paper, the acoustic emission (AE) response of coal samples under cyclic loading is measured. The results show that there is good positive relation between AE parameters and stress. The AE signal of coal samples under cyclic loading exhibits an obvious Kaiser Effect. The single-link cluster (SLC) method is applied to analyze the spatial evolution characteristics of AE events and the damage evolution process of coal samples. It is found that a subset scale of the SLC structure becomes smaller and smaller when the number of cyclic loading increases, and there is a negative linear relationship between the subset scale and the degree of damage. The spatial correlation length ξ of an SLC structure is calculated. The results show that ξ fluctuates around a certain value from the second cyclic loading process to the fifth cyclic loading process, but spatial correlation length ξ clearly increases in the sixth loading process. Based on the criterion of microcrack density, the coal sample failure process is the transformation from small-scale damage to large-scale damage, which is the reason for changes in the spatial correlation length. Through a systematic analysis, the SLC method is an effective method to research the damage evolution process of coal samples under cyclic loading, and will provide important reference values for studying coal bursts.

  20. Ten Things Every Professor Should Know about Assessment

    Science.gov (United States)

    Wolf, Kenneth; Dunlap, Joanna; Stevens, Ellen

    2012-01-01

    This article describes ten key assessment practices for advancing student learning that all professors should be familiar with and strategically incorporate in their classrooms and programs. Each practice or concept is explained with examples and guidance for putting it into practice. The ten are: learning outcomes, performance assessments,…

  1. Determination of the levels of trace elements in ten years old children from Antofagasta city, Chile by neutron activation analysis

    International Nuclear Information System (INIS)

    Gras, N.; Munoz, A.L.; Jamett J, A.; Pena C, L.; Santander M, M.

    1988-01-01

    The levels of trace elements in scalp hair of ten years old children of Antofagasta city were determined. For this study, the city was divided in convenient areas. Comparisons between levels of concentrations considering residential areas, sex, values obtained for children of Santiago, and the ranges given in the literature were established. Fifty samples of hair were analyzed by instrumental neutron activation analisis. The elements selected were: As, Br, Co, Cr, Cu, Fe, Hg, K, Na. Sb, and Zn. The effectiveness of wash procedure before irradiation was studied. Ten samples were taken with sufficient amount of hair and each was divided into two, only one of them was washed and both were analyzed. The levels of concentrations were compared. (author)

  2. Sampling system for fast single pulses; Realisation d'un dispositif d'echantillonnage d'un signal bref unique

    Energy Technology Data Exchange (ETDEWEB)

    Zenatti, D [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1969-07-01

    Development of a device for the enlargement of the domain of application of classical oscilloscopes to the observation of fast single pulses by application of the sampling principle. Its principal characteristics are: Bandwidth of 700 MHz; Maximum sensibility of 50 mV; Maximum amplitude of input signal of {+-} 1 V; Number of samples of 16; Samples separation of 0,2 ns. (author) [French] Realisation d'un dispositif permettant d'elargir le domaine d'utilisation des oscilloscopes classiques en appliquant le principe de l'echantillonnage a l'observation d'un signal bref unique. Les principales caracteristiques sont les suivantes: Bande passante de 700 MHz; Sensibilite maximale de 50 mV; Amplitude maximale du signal a echantillonner de {+-} 1 V; Nombre de points d'echantillonnage de 16; Pas d'echantillonnage de 0,2 ns. (auteur)

  3. SPIDER ® sleeve gastrectomy--a new concept in single-trocar bariatric surgery: initial experience and technical details.

    Science.gov (United States)

    Noel, P; Nedelcu, M; Gagner, M

    2014-04-01

    Single port instrument delivery extended reach (SPIDER(®)) surgical system is a revolutionary surgical platform that allows triangulation of the surgical instruments while eliminating the crossing of instruments, the problematic characteristic of single access laparoscopic surgery. The purpose of this study was to analyze our initial experience with SPIDER(®) sleeve gastrectomy and to present the technical details of this new minimally invasive approach, performed in ten patients at the La Casamance Private Hospital between November 2012 and April 2013. All patients were reviewed at scheduled post-operative consultations at 1, 3 and 6 months. In addition to clinical examination, the post-operative consultation at one month also included a satisfaction survey using the Moorehead-Ardelt questionnaire. An initial series of ten sleeve gastrectomies were performed in female patients with a mean age of 41.5 years (range: 2-52). The mean BMI was 40.11 (range: 37.25-44.3). The intervention was performed through a single trocar in all patients with no "conversion" to classic laparoscopy or open surgery. The mean operative time was 61 ± 15.22 minutes (SD=standard deviation) (range: 43-96 min). The mean BMI at one month was 35.5 (SD:± 3.58, SEM: ± 1.13) (SEM=standard error of mean) with an average percentage of excess weight loss (%EWL) of 32.9% (SD:± 8.56%, SEM:± 2.71%). The mean BMI at three months was 32.4 (SD: ± 2.78, SEM: ± 0.88) with an average %EWL of 52.7% (SD: ± 8.64%, SEM: ± 2.73%). The mean BMI at six months was 29.9 (SD:± 2.60, SEM: ± 0.98) with a mean %EWL of 68.8% (SD: ± 8.38%, SEM:± 3.17%). Complete remission of co-morbid conditions was observed in four patients, improvement in three others, and no change in a single patient. The mean duration of hospitalization was 3.1 days. The mean follow-up period was 161 days (SD:± 57.4 days, range: 90-243 days). There was no mortality and no intra-operative and post-operative complications were noted. The

  4. Single visit nonsurgical endodontic therapy for periapical cysts: A clinical study

    Directory of Open Access Journals (Sweden)

    Ipsita Maity

    2014-01-01

    Full Text Available Aims: The aim of this study was to assess the outcome of single sitting root canal treatment (RCT of asymptomatic teeth with periapical cysts. Materials and Methods: Ten maxillary anterior teeth showing periapical lesion on the radiograph was further screened by ultrasound with color power Doppler (CPD for confirmation of a cyst. The average dimension of the lesions ranged from 1.3 to 1.9 cm. Single sitting RCT was performed on all the selected teeth. Postoperative healing was monitored at regular interval of 3 months, 6 months, and 1 year by using subjective feedback, radiograph, and ultrasound with CPD study. Results: Eight among the ten cases showed either signs of complete healing or healing in progress by the end of 6-12 months. Conclusions: It was observed that single sitting nonsurgical endodontic management of asymptomatic teeth with periapical cyst confirmed by ultrasound was successful in selected cases.

  5. An automatic sample changer for use on the SNS

    International Nuclear Information System (INIS)

    1982-10-01

    A design for an Automatic Room Temperature Sample Changer suitable for any completely contained sample, gas, liquid or solid, has been produced. Samples can be moved in any sequence into the neutron beam. The design was evolved primarily to suit SNS instruments. A prototype was constructed specifically for the LAD spectrometer having ten sample positions. The accuracy of the sample positioning was determined. (author)

  6. BOREAS/AES Campbell Scientific 15-minute Surface Meteorological Data: 1994

    Data.gov (United States)

    National Aeronautics and Space Administration — Contains data from 1994 from the Atmospheric Environment Service Campbell Scientific autostations collecting continuous fifteen minute data for BOREAS.

  7. BOREAS/AES Campbell Scientific 15-minute Surface Meteorological Data: 1996

    Data.gov (United States)

    National Aeronautics and Space Administration — Contains data from 1996 from the Atmospheric Environment Service Campbell Scientific autostations collecting continuous fifteen minute data for BOREAS.

  8. BOREAS/AES Campbell Scientific 15-minute Surface Meteorological Data: 1995

    Data.gov (United States)

    National Aeronautics and Space Administration — Contains data from 1995 from the Atmospheric Environment Service Campbell Scientific autostations collecting continuous fifteen minute data for BOREAS.

  9. Diagnosing intramammary infections: evaluation of definitions based on a single milk sample.

    Science.gov (United States)

    Dohoo, I R; Smith, J; Andersen, S; Kelton, D F; Godden, S

    2011-01-01

    Criteria for diagnosing intramammary infections (IMI) have been debated for many years. Factors that may be considered in making a diagnosis include the organism of interest being found on culture, the number of colonies isolated, whether or not the organism was recovered in pure or mixed culture, and whether or not concurrent evidence of inflammation existed (often measured by somatic cell count). However, research using these criteria has been hampered by the lack of a "gold standard" test (i.e., a perfect test against which the criteria can be evaluated) and the need for very large data sets of culture results to have sufficient numbers of quarters with infections with a variety of organisms. This manuscript used 2 large data sets of culture results to evaluate several definitions (sets of criteria) for classifying a quarter as having, or not having an IMI by comparing the results from a single culture to a gold standard diagnosis based on a set of 3 milk samples. The first consisted of 38,376 milk samples from which 25,886 triplicate sets of milk samples taken 1 wk apart were extracted. The second consisted of 784 quarters that were classified as infected or not based on a set of 3 milk samples collected at 2-d intervals. From these quarters, a total of 3,136 additional samples were evaluated. A total of 12 definitions (named A to L) based on combinations of the number of colonies isolated, whether or not the organism was recovered in pure or mixed culture, and the somatic cell count were evaluated for each organism (or group of organisms) with sufficient data. The sensitivity (ability of a definition to detect IMI) and the specificity (Sp; ability of a definition to correctly classify noninfected quarters) were both computed. For all species, except Staphylococcus aureus, the sensitivity of all definitions was definition A). With the exception of "any organism" and coagulase-negative staphylococci, all Sp estimates were over 94% in the daily data and over 97

  10. A reliable method for the counting and control of single ions for single-dopant controlled devices

    International Nuclear Information System (INIS)

    Shinada, T; Kurosawa, T; Nakayama, H; Zhu, Y; Hori, M; Ohdomari, I

    2008-01-01

    By 2016, transistor device size will be just 10 nm. However, a transistor that is doped at a typical concentration of 10 18 atoms cm -3 has only one dopant atom in the active channel region. Therefore, it can be predicted that conventional doping methods such as ion implantation and thermal diffusion will not be available ten years from now. We have been developing a single-ion implantation (SII) method that enables us to implant dopant ions one-by-one into semiconductors until the desired number is reached. Here we report a simple but reliable method to control the number of single-dopant atoms by detecting the change in drain current induced by single-ion implantation. The drain current decreases in a stepwise fashion as a result of the clusters of displaced Si atoms created by every single-ion incidence. This result indicates that the single-ion detection method we have developed is capable of detecting single-ion incidence with 100% efficiency. Our method potentially could pave the way to future single-atom devices, including a solid-state quantum computer

  11. A 15-minute interactive, computerized condom use intervention with biological endpoints.

    Science.gov (United States)

    Grimley, Diane M; Hook, Edward W

    2009-02-01

    Brief face-to-face-behavioral interventions have been shown to be efficacious, but are costly to sustain and to widely disseminate. This study evaluated the efficacy of a 15-minute theory-based behavioral intervention designed to increase condom use and reduce new cases of Neisseria gonorrhoeae and Chlamydia trachomatis. Participants were randomly assigned via the computer to the intervention or the comparison group stratified by gender and their baseline stage of change (motivational readiness) for using condoms consistently (100%) with their main partners. Behavioral data and biologic specimens for testing of Neisseria gonorrhoeae and Chlamydia trachomatis were obtained at baseline and at 6 months post intervention. The intervention was delivered via an audio, multimedia, computerized application that provided individualized interventions to patients based on their responses to assessment items; comparison patients interacted with a 15-minute, computerized, multiple health risk assessment with no intervention. The majority of the sample (N = 430) was black (88%); 54.5% women; with a mean age = 24.5. Assuming all participants who did not return to the clinic at 6 months were not using condoms consistently, 32% of the treatment group versus 23% in the comparison group reported consistent condom use (P = 0.03). The combined Neisseria gonorrhoeae and Chlamydia trachomatis incidence declined to 6% in the intervention group versus 13% in the comparison group (P = 0.04). Results from a regression analysis revealed that the only statically significant predictor of sexually transmitted diseases infection at the follow-up was group assignment (OR = 1.91, 95% confidence index = 1.09-3.34; P = 0.043). These findings suggest that brief, interactive, computer-delivered interventions provided at the evaluation visit increase condom use and reduce sexually transmitted diseases without putting additional burden on clinicians or staff.

  12. Six-minute-walk test in chronic obstructive pulmonary disease

    DEFF Research Database (Denmark)

    Polkey, Michael I; Spruit, Martijn A; Edwards, Lisa D

    2013-01-01

    Outcomes other than spirometry are required to assess nonbronchodilator therapies for chronic obstructive pulmonary disease. Estimates of the minimal clinically important difference for the 6-minute-walk distance (6MWD) have been derived from narrow cohorts using nonblinded intervention....

  13. ABACC ten years applying safeguards

    International Nuclear Information System (INIS)

    Palacios, Elias

    2001-01-01

    The Argentinian-Brazilian Agency for Accounting and Control of nuclear special materials has been in operations for ten years. The rational behind the creation and the work performed by the Agency during the last decade is described. (author)

  14. BOREAS/AES Campbell Scientific 15-minute Surface Meteorological Data: 1995

    Data.gov (United States)

    National Aeronautics and Space Administration — ABSTRACT: Contains data from 1995 from the Atmospheric Environment Service Campbell Scientific autostations collecting continuous fifteen minute data for BOREAS.

  15. Assessing play-based activities, child talk, and single session outcome in family therapy with young children.

    Science.gov (United States)

    Willis, Amber B; Walters, Lynda H; Crane, D Russell

    2014-07-01

    This exploratory, observational study was designed to reveal descriptive information regarding therapists' actual practices with preschool- and school-aged children in a single session of family therapy and to investigate change mechanisms in family play therapy that have been proposed to make this approach effective. A purposive sample of 30 families receiving family therapy was recruited and video-taped during a family session where at least one child between the ages of 4 and 12 was present. Following the session, the therapist and parent(s) completed questionnaires while one of the children (aged 4-12) was interviewed. Session recordings were coded, minute-by-minute, for participant talk time, visual aids or props used, and therapy technique type (e.g., play-based/activity vs. talk-only techniques). Hierarchical regression and canonical correlational analyses revealed evidence supporting the theory that play-based techniques promote young children's participation, enhance the quality of the child-therapist relationship, and build positive emotional experiences in family therapy. © 2013 American Association for Marriage and Family Therapy.

  16. Determination of plutonium in air and smear samples

    International Nuclear Information System (INIS)

    Hinton, E.R. Jr.; Tucker, W.O.

    1981-01-01

    A method has been developed for the determination of plutonium in air samples and smear samples that were collected on filter papers. The sample papers are digested in nitric acid, extracted into 2-thenoyltrifluoroacetone (TTA)-xylene, and evaporated onto stainless steel disks. Alpha spectrometry is employed to determine the activity of each plutonium isotope. Each sample is spiked with plutonium-236. All glassware used in the procedure is disposable. The detection limits are 3 and 5 dpm (disintegrations per minute) for air and smear samples, respectively, with an average recovery of 87%

  17. Single-gene prognostic signatures for advanced stage serous ovarian cancer based on 1257 patient samples.

    Science.gov (United States)

    Zhang, Fan; Yang, Kai; Deng, Kui; Zhang, Yuanyuan; Zhao, Weiwei; Xu, Huan; Rong, Zhiwei; Li, Kang

    2018-04-16

    We sought to identify stable single-gene prognostic signatures based on a large collection of advanced stage serous ovarian cancer (AS-OvCa) gene expression data and explore their functions. The empirical Bayes (EB) method was used to remove the batch effect and integrate 8 ovarian cancer datasets. Univariate Cox regression was used to evaluate the association between gene and overall survival (OS). The Database for Annotation, Visualization and Integrated Discovery (DAVID) tool was used for the functional annotation of genes for Gene Ontology (GO) terms and Kyoto Encyclopedia of Genes and Genomes (KEGG) pathways. The batch effect was removed by the EB method, and 1257 patient samples were used for further analysis. We selected 341 single-gene prognostic signatures with FDR matrix organization, focal adhesion and DNA replication which are closely associated with cancer. We used the EB method to remove the batch effect of 8 datasets, integrated these datasets and identified stable prognosis signatures for AS-OvCa.

  18. EEG Correlates of Ten Positive Emotions.

    Science.gov (United States)

    Hu, Xin; Yu, Jianwen; Song, Mengdi; Yu, Chun; Wang, Fei; Sun, Pei; Wang, Daifa; Zhang, Dan

    2017-01-01

    Compared with the well documented neurophysiological findings on negative emotions, much less is known about positive emotions. In the present study, we explored the EEG correlates of ten different positive emotions (joy, gratitude, serenity, interest, hope, pride, amusement, inspiration, awe, and love). A group of 20 participants were invited to watch 30 short film clips with their EEGs simultaneously recorded. Distinct topographical patterns for different positive emotions were found for the correlation coefficients between the subjective ratings on the ten positive emotions per film clip and the corresponding EEG spectral powers in different frequency bands. Based on the similarities of the participants' ratings on the ten positive emotions, these emotions were further clustered into three representative clusters, as 'encouragement' for awe, gratitude, hope, inspiration, pride, 'playfulness' for amusement, joy, interest, and 'harmony' for love, serenity. Using the EEG spectral powers as features, both the binary classification on the higher and lower ratings on these positive emotions and the binary classification between the three positive emotion clusters, achieved accuracies of approximately 80% and above. To our knowledge, our study provides the first piece of evidence on the EEG correlates of different positive emotions.

  19. Preparation and Loading Process of Single Crystalline Samples into a Gas Environmental Cell Holder for In Situ Atomic Resolution Scanning Transmission Electron Microscopic Observation.

    Science.gov (United States)

    Straubinger, Rainer; Beyer, Andreas; Volz, Kerstin

    2016-06-01

    A reproducible way to transfer a single crystalline sample into a gas environmental cell holder for in situ transmission electron microscopic (TEM) analysis is shown in this study. As in situ holders have only single-tilt capability, it is necessary to prepare the sample precisely along a specific zone axis. This can be achieved by a very accurate focused ion beam lift-out preparation. We show a step-by-step procedure to prepare the sample and transfer it into the gas environmental cell. The sample material is a GaP/Ga(NAsP)/GaP multi-quantum well structure on Si. Scanning TEM observations prove that it is possible to achieve atomic resolution at very high temperatures in a nitrogen environment of 100,000 Pa.

  20. Using TENS for pain control: the state of the evidence

    Science.gov (United States)

    Vance, Carol GT; Dailey, Dana L; Rakel, Barbara A; Sluka, Kathleen A

    2014-01-01

    Summary Transcutaneous electrical nerve stimulation (TENS) is a nonpharmacological intervention that activates a complex neuronal network to reduce pain by activating descending inhibitory systems in the central nervous system to reduce hyperalgesia. The evidence for TENS efficacy is conflicting and requires not only description but also critique. Population-specific systemic reviews and meta-analyses are emerging, indicating both HF and LF TENS being shown to provide analgesia, specifically when applied at a strong, nonpainful intensity. The purpose of this article is to provide a critical review of the latest basic science and clinical evidence for TENS. Additional research is necessary to determine if TENS has effects specific to mechanical stimuli and/or beyond reduction of pain and will improve activity levels, function and quality of life. PMID:24953072

  1. Vodacom and MTN’s brand positioning based on the perceptions of a group of LSM seven to ten respondents

    Directory of Open Access Journals (Sweden)

    Hennie Mentz

    2013-02-01

    Full Text Available This article investigates Vodacom and MTN’s brand positioning based on the perceptions of a group of LSM seven to ten respondents who are principal estate agents in Gauteng. An empirical study was conducted. The profile of the sample in terms of access to telecommunication-related services confirmed that of individuals in the LSM seven to ten groups with a skew towards LSM ten. As a minimum requirement for the target market brands in the category should be strongly associated with the statements market leader, local brand, technologically sophisticated brand, trusted brand, South African brand and prestigious/upmarket brand. At an overall level, Vodacom has established a more favourable brand positioning compared to MTN. However, both Vodacom and MTN have failed to establish a personal brand relationship with the target market.

  2. Nanoscale temperature sensing using single defects in diamond

    International Nuclear Information System (INIS)

    Philipp Neumann

    2014-01-01

    We experimentally demonstrate a novel nanoscale temperature sensing technique that is based on single atomic defects in diamonds, namely nitrogen vacancy color centers. Sample sizes range from millimeter down to a few tens of nanometers. In particular nanodiamonds were used as dispersed probes to acquire spatially resolved temperature profiles utilizing the sensitivity of the optically accessible electron spin level structure we achieve a temperature noise floor of 5mK/Mhz for bulk diamond and 130mK/Mhz for nanodiamonds and accuracies of 1mK. To this end we have developed a new decoupling technique in order to suppress to otherwise limiting effect of magnetic field fluctuations. In addition, high purity isotopically enriched 12C artificial diamonds is used. The high sensitivity to temperature changes adds to the well studied sensitivities to magnetic and electric fields and makes NV diamond a multipurpose nanoprobe. (author)

  3. Paper-based device for separation and cultivation of single microalga.

    Science.gov (United States)

    Chen, Chih-Chung; Liu, Yi-Ju; Yao, Da-Jeng

    2015-12-01

    Single-cell separation is among the most useful techniques in biochemical research, diagnosis and various industrial applications. Microalgae species have great economic importance as industrial raw materials. Microalgae species collected from environment are typically a mixed and heterogeneous population of species that must be isolated and purified for examination and further application. Conventional methods, such as serial dilution and a streaking-plate method, are intensive of labor and inefficient. We developed a paper-based device for separation and cultivation of single microalga. The fabrication was simply conducted with a common laser printer and required only a few minutes without lithographic instruments and clean-room. The driving force of the paper device was simple capillarity without a complicated pump connection that is part of most devices for microfluidics. The open-structure design of the paper device makes it operable with a common laboratory micropipette for sample transfer and manipulation with a naked eye or adaptable to a robotic system with functionality of high-throughput retrieval and analysis. The efficiency of isolating a single cell from mixed microalgae species is seven times as great as with a conventional method involving serial dilution. The paper device can serve also as an incubator for microalgae growth on simply rinsing the paper with a growth medium. Many applications such as highly expressed cell selection and various single-cell analysis would be applicable. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. Development of an ELISA microarray assay for the sensitive and simultaneous detection of ten biodefense toxins.

    Energy Technology Data Exchange (ETDEWEB)

    Jenko, Kathryn; Zhang, Yanfeng; Kostenko, Yulia; Fan, Yongfeng; Garcia-Rodriguez, Consuelo; Lou, Jianlong; Marks, James D.; Varnum, Susan M.

    2014-10-21

    Plant and microbial toxins are considered bioterrorism threat agents because of their extreme toxicity and/or ease of availability. Additionally, some of these toxins are increasingly responsible for accidental food poisonings. The current study utilized an ELISA-based protein antibody microarray for the multiplexed detection of ten biothreat toxins, botulinum neurotoxins (BoNT) A, B, C, D, E, F, ricin, shiga toxins 1 and 2 (Stx), and staphylococcus enterotoxin B (SEB), in buffer and complex biological matrices. The multiplexed assay displayed a sensitivity of 1.3 pg/mL (BoNT/A, BoNT/B, SEB, Stx-1 and Stx-2), 3.3 pg/mL (BoNT/C, BoNT/E, BoNT/F) and 8.2 pg/mL (BoNT/D, ricin). All assays demonstrated high accuracy (75-120 percent recovery) and reproducibility (most coefficients of variation < 20%). Quantification curves for the ten toxins were also evaluated in clinical samples (serum, plasma, nasal fluid, saliva, stool, and urine) and environmental samples (apple juice, milk and baby food) with overall minimal matrix effects. The multiplex assays were highly specific, with little crossreactivity observed between the selected toxin antibodies. The results demonstrate a multiplex microarray that improves current immunoassay sensitivity for biological warfare agents in buffer, clinical, and environmental samples.

  5. 12 CFR 701.3 - Member inspection of credit union books, records, and minutes.

    Science.gov (United States)

    2010-01-01

    ... 12 Banks and Banking 6 2010-01-01 2010-01-01 false Member inspection of credit union books... inspection of credit union books, records, and minutes. (a) Member inspection rights. A group of members of a...) Accounting books and records; and (2) Minutes of the proceedings of the credit union's members, board of...

  6. Optimal sampling theory and population modelling - Application to determination of the influence of the microgravity environment on drug distribution and elimination

    Science.gov (United States)

    Drusano, George L.

    1991-01-01

    The optimal sampling theory is evaluated in applications to studies related to the distribution and elimination of several drugs (including ceftazidime, piperacillin, and ciprofloxacin), using the SAMPLE module of the ADAPT II package of programs developed by D'Argenio and Schumitzky (1979, 1988) and comparing the pharmacokinetic parameter values with results obtained by traditional ten-sample design. The impact of the use of optimal sampling was demonstrated in conjunction with NONMEM (Sheiner et al., 1977) approach, in which the population is taken as the unit of analysis, allowing even fragmentary patient data sets to contribute to population parameter estimates. It is shown that this technique is applicable in both the single-dose and the multiple-dose environments. The ability to study real patients made it possible to show that there was a bimodal distribution in ciprofloxacin nonrenal clearance.

  7. Stunning and Right Ventricular Dysfunction Is Induced by Coronary Balloon Occlusion and Rapid Pacing in Humans: Insights From Right Ventricular Conductance Catheter Studies.

    Science.gov (United States)

    Axell, Richard G; Giblett, Joel P; White, Paul A; Klein, Andrew; Hampton-Til, James; O'Sullivan, Michael; Braganza, Denise; Davies, William R; West, Nick E J; Densem, Cameron G; Hoole, Stephen P

    2017-06-06

    We sought to determine whether right ventricular stunning could be detected after supply (during coronary balloon occlusion [BO]) and supply/demand ischemia (induced by rapid pacing [RP] during transcatheter aortic valve replacement) in humans. Ten subjects with single-vessel right coronary artery disease undergoing percutaneous coronary intervention with normal ventricular function were studied in the BO group. Ten subjects undergoing transfemoral transcatheter aortic valve replacement were studied in the RP group. In both, a conductance catheter was placed into the right ventricle, and pressure volume loops were recorded at baseline and for intervals over 15 minutes after a low-pressure BO for 1 minute or a cumulative duration of RP for up to 1 minute. Ischemia-induced diastolic dysfunction was seen 1 minute after RP (end-diastolic pressure [mm Hg]: 8.1±4.2 versus 12.1±4.1, P right coronary artery balloon occlusion both cause ischemic right ventricular dysfunction with stunning observed later during the procedure. This may have intraoperative implications in patients without right ventricular functional reserve. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  8. One Minute of Marijuana Secondhand Smoke Exposure Substantially Impairs Vascular Endothelial Function.

    Science.gov (United States)

    Wang, Xiaoyin; Derakhshandeh, Ronak; Liu, Jiangtao; Narayan, Shilpa; Nabavizadeh, Pooneh; Le, Stephenie; Danforth, Olivia M; Pinnamaneni, Kranthi; Rodriguez, Hilda J; Luu, Emmy; Sievers, Richard E; Schick, Suzaynn F; Glantz, Stanton A; Springer, Matthew L

    2016-07-27

    Despite public awareness that tobacco secondhand smoke (SHS) is harmful, many people still assume that marijuana SHS is benign. Debates about whether smoke-free laws should include marijuana are becoming increasingly widespread as marijuana is legalized and the cannabis industry grows. Lack of evidence for marijuana SHS causing acute cardiovascular harm is frequently mistaken for evidence that it is harmless, despite chemical and physical similarity between marijuana and tobacco smoke. We investigated whether brief exposure to marijuana SHS causes acute vascular endothelial dysfunction. We measured endothelial function as femoral artery flow-mediated dilation (FMD) in rats before and after exposure to marijuana SHS at levels similar to real-world tobacco SHS conditions. One minute of exposure to marijuana SHS impaired FMD to a comparable extent as impairment from equal concentrations of tobacco SHS, but recovery was considerably slower for marijuana. Exposure to marijuana SHS directly caused cannabinoid-independent vasodilation that subsided within 25 minutes, whereas FMD remained impaired for at least 90 minutes. Impairment occurred even when marijuana lacked cannabinoids and rolling paper was omitted. Endothelium-independent vasodilation by nitroglycerin administration was not impaired. FMD was not impaired by exposure to chamber air. One minute of exposure to marijuana SHS substantially impairs endothelial function in rats for at least 90 minutes, considerably longer than comparable impairment by tobacco SHS. Impairment of FMD does not require cannabinoids, nicotine, or rolling paper smoke. Our findings in rats suggest that SHS can exert similar adverse cardiovascular effects regardless of whether it is from tobacco or marijuana. © 2016 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.

  9. Acute effects of a single warm-water bath on serum adiponectin and leptin levels in healthy men: A pilot study

    Science.gov (United States)

    Shimodozono, Megumi; Matsumoto, Shuji; Ninomiya, Koji; Miyata, Ryuji; Ogata, Atsuko; Etoh, Seiji; Watanabe, Satoshi; Kawahira, Kazumi

    2012-09-01

    To preliminarily assess the acute effects of a single warm -water bath (WWB) on serum adipokine activity, we measured serum adiponectin, leptin and other metabolic profiles before, immediately after and 30 minutes after WWB in seven healthy male volunteers (mean age, 39.7 ± 6.0 years; mean body mass index, 21.6 ± 1.8 kg/m2). The subjects were immersed in tap water at 41°C for 10 minutes. Two weeks later, the same subjects underwent a single WWB with a bath additive that included inorganic salts and carbon dioxide (WWB with ISCO2) by the same protocol as for the first WWB. Leptin levels significantly increased immediately after WWB with tap water and ISCO2 (both P hemoglobin and hematocrit significantly increased immediately after WWB with tap water or ISCO2 (all P < 0.05), but they all returned to the baseline levels 30 minutes after bathing under both conditions. The sublingual temperature rose significantly after 10 minutes of WWB with tap water (0.96 ± 0.16°C relative to baseline, P < 0.01) and after the same duration of WWB with ISCO2 (1.24 ± 0.34°C relative to baseline, P < 0.01). These findings suggest that a single WWB at 41°C for 10 minutes may modulate leptin and adiponectin profiles in healthy men.

  10. Spatial distribution of single-nucleotide polymorphisms related to fungicide resistance and implications for sampling.

    Science.gov (United States)

    Van der Heyden, H; Dutilleul, P; Brodeur, L; Carisse, O

    2014-06-01

    Spatial distribution of single-nucleotide polymorphisms (SNPs) related to fungicide resistance was studied for Botrytis cinerea populations in vineyards and for B. squamosa populations in onion fields. Heterogeneity in this distribution was characterized by performing geostatistical analyses based on semivariograms and through the fitting of discrete probability distributions. Two SNPs known to be responsible for boscalid resistance (H272R and H272Y), both located on the B subunit of the succinate dehydrogenase gene, and one SNP known to be responsible for dicarboximide resistance (I365S) were chosen for B. cinerea in grape. For B. squamosa in onion, one SNP responsible for dicarboximide resistance (I365S homologous) was chosen. One onion field was sampled in 2009 and another one was sampled in 2010 for B. squamosa, and two vineyards were sampled in 2011 for B. cinerea, for a total of four sampled sites. Cluster sampling was carried on a 10-by-10 grid, each of the 100 nodes being the center of a 10-by-10-m quadrat. In each quadrat, 10 samples were collected and analyzed by restriction fragment length polymorphism polymerase chain reaction (PCR) or allele specific PCR. Mean SNP incidence varied from 16 to 68%, with an overall mean incidence of 43%. In the geostatistical analyses, omnidirectional variograms showed spatial autocorrelation characterized by ranges of 21 to 1 m. Various levels of anisotropy were detected, however, with variograms computed in four directions (at 0°, 45°, 90°, and 135° from the within-row direction used as reference), indicating that spatial autocorrelation was prevalent or characterized by a longer range in one direction. For all eight data sets, the β-binomial distribution was found to fit the data better than the binomial distribution. This indicates local aggregation of fungicide resistance among sampling units, as supported by estimates of the parameter θ of the β-binomial distribution of 0.09 to 0.23 (overall median value = 0

  11. Estimation of 131J-Jodohippurateclearance by a simplified method using a single plasma sample

    International Nuclear Information System (INIS)

    Botsch, H.; Golde, G.; Kampf, D.

    1980-01-01

    Theoretical volumes calculated from the reciprocal of the plasma concentration of 131 J-Jodohippurate were compared in 95 patients with clearance values calculated by the 2-compartment-method and in 18 patients with conventional PAH-clearance. For estimating Hippurate-clearance from a single blood sampling the most favorable time is 45 min. after injection (r = 0.96; clearance 400/ml/min.: r = 0.98). Clearance values may be derived from the formula: C = 0.4 + 7.26 V - 0.021 x V 2 (V = injected activity/activity per l plasma taken 45 min. after injection). The simplicity, precision and reproducibility of the above mentioned clearance-method is emphasized. (orig.) [de

  12. Tuberculosis Biomarker Extraction and Isothermal Amplification in an Integrated Diagnostic Device.

    Directory of Open Access Journals (Sweden)

    Amy Creecy

    Full Text Available In this study, we integrated magnetic bead-based sample preparation and isothermal loop mediated amplification (LAMP of TB in a single tube. Surrogate sputum samples produced by the Program for Appropriate Technology in Health containing inactivated TB bacteria were used to test the diagnostic. In order to test the sample preparation method, samples were lysed, and DNA was manually extracted and eluted into water in the tube. In a thermal cycler, LAMP amplified TB DNA from 103 TB cells/mL of sputum at 53.5 ± 3.3 minutes, 104 cells/mL at 46.3 ± 2.2 minutes, and 105 cells/mL at 41.6 ± 1.9 minutes. Negative control samples did not amplify. Next, sample preparation was combined with in-tubing isothermal LAMP amplification by replacing the water elution chamber with a LAMP reaction chamber. In this intermediate configuration, LAMP amplified 103 cells/mL at 74 ± 10 minutes, 104 cells/mL at 60 ± 9 minutes, and 105 TB cells/mL of sputum at 54 ± 9 minutes. Two of three negative controls did not amplify; one amplified at 100 minutes. In the semi-automated system, DNA was eluted directly into an isothermal reaction solution containing the faster OptiGene DNA polymerase. The low surrogate sputum concentration, 103 TB cells/mL, amplified at 52.8 ± 3.3 minutes, 104 cells/mL at 45.4 ± 11.3 minutes, and 105 cells/mL at 31.8 ± 2.9 minutes. TB negative samples amplified at 66.4 ± 7.4 minutes. This study demonstrated the feasibility of a single tube design for integrating sample preparation and isothermal amplification, which with further development could be useful for point-of-care applications, particularly in a low-resource setting.

  13. Ten Tips for Parents to Help Their Children Avoid Teen Pregnancy

    Science.gov (United States)

    ... we do » Resource library » Ten tips for parents Ten Tips for Parents to Help Their Children Avoid Teen Pregnancy Publication Created with Sketch. Ten Tips for Parents to Help Their Children Avoid ...

  14. Sequentially allocated clinical trial of rhythmic stabilization exercises and TENS in women with chronic low back pain.

    Science.gov (United States)

    Kofotolis, Nikolaos D; Vlachopoulos, Symeon P; Kellis, Eleftherios

    2008-02-01

    To examine the effectiveness of rhythmic stabilization exercises and transcutaneous electrical nerve stimulation (TENS) and their combination in treating women with chronic low back pain. Sequentially allocated, single-blinded and controlled study, with a two-month follow-up. The data were collected in a patient rehabilitation setting. A total of 92 women (34-46 years old) with chronic low back pain were studied. Sequential allocation was undertaken into four groups: ;rhythmic stabilization' (n=23), ;rhythmic stabilization - TENS' (n=23), TENS (n=23), and a placebo group (n = 23). Each programme lasted for four weeks. All outcome measures were assessed prior to, immediately after, four weeks and eight weeks post intervention. Data were obtained on functional disability, pain intensity, trunk extension range of motion, dynamic endurance of trunk flexion and static endurance of trunk extension. A total of 88 patients provided two-month follow-up data. The ;rhythmic stabilization' and the ;rhythmic stabilization - TENS' groups displayed statistically significant (Ppain intensity (ranging from 21.2 to 42.8%), trunk extension range of motion (ranging from 6.5 to 25.5%), dynamic endurance of trunk flexion and static endurance of trunk extension (ranging from 13.5 to 74.3%) compared with the remaining groups. The rhythmic stabilization programmes resulted in more gains in women with chronic low back pain regarding the present outcome variables compared with the other groups; therefore, its application in female chronic low back pain patients aged 34-46 years is recommended.

  15. Optofluidic analysis system for amplification-free, direct detection of Ebola infection

    Science.gov (United States)

    Cai, H.; Parks, J. W.; Wall, T. A.; Stott, M. A.; Stambaugh, A.; Alfson, K.; Griffiths, A.; Mathies, R. A.; Carrion, R.; Patterson, J. L.; Hawkins, A. R.; Schmidt, H.

    2015-09-01

    The massive outbreak of highly lethal Ebola hemorrhagic fever in West Africa illustrates the urgent need for diagnostic instruments that can identify and quantify infections rapidly, accurately, and with low complexity. Here, we report on-chip sample preparation, amplification-free detection and quantification of Ebola virus on clinical samples using hybrid optofluidic integration. Sample preparation and target preconcentration are implemented on a PDMS-based microfluidic chip (automaton), followed by single nucleic acid fluorescence detection in liquid-core optical waveguides on a silicon chip in under ten minutes. We demonstrate excellent specificity, a limit of detection of 0.2 pfu/mL and a dynamic range of thirteen orders of magnitude, far outperforming other amplification-free methods. This chip-scale approach and reduced complexity compared to gold standard RT-PCR methods is ideal for portable instruments that can provide immediate diagnosis and continued monitoring of infectious diseases at the point-of-care.

  16. A polypeptide-DNA hybrid with selective linking capability applied to single molecule nano-mechanical measurements using optical tweezers.

    Directory of Open Access Journals (Sweden)

    Fatemeh Moayed

    Full Text Available Many applications in biosensing, biomaterial engineering and single molecule biophysics require multiple non-covalent linkages between DNA, protein molecules, and surfaces that are specific yet strong. Here, we present a novel method to join proteins and dsDNA molecule at their ends, in an efficient, rapid and specific manner, based on the recently developed linkage between the protein StrepTactin (STN and the peptide StrepTag II (ST. We introduce a two-step approach, in which we first construct a hybrid between DNA and a tandem of two STs peptides (tST. In a second step, this hybrid is linked to polystyrene bead surfaces and Maltose Binding Protein (MBP using STN. Furthermore, we show the STN-tST linkage is more stable against forces applied by optical tweezers than the commonly used biotin-Streptavidin (STV linkage. It can be used in conjunction with Neutravidin (NTV-biotin linkages to form DNA tethers that can sustain applied forces above 65 pN for tens of minutes in a quarter of the cases. The method is general and can be applied to construct other surface-DNA and protein-DNA hybrids. The reversibility, high mechanical stability and specificity provided by this linking procedure make it highly suitable for single molecule mechanical studies, as well as biosensing and lab on chip applications.

  17. A suspended-particle rosette multi-sampler for discrete biogeochemical sampling in low-particle-density waters

    Energy Technology Data Exchange (ETDEWEB)

    Breier, J. A.; Rauch, C. G.; McCartney, K.; Toner, B. M.; Fakra, S. C.; White, S. N.; German, C. R.

    2010-06-22

    To enable detailed investigations of early stage hydrothermal plume formation and abiotic and biotic plume processes we developed a new oceanographic tool. The Suspended Particulate Rosette sampling system has been designed to collect geochemical and microbial samples from the rising portion of deep-sea hydrothermal plumes. It can be deployed on a remotely operated vehicle for sampling rising plumes, on a wire-deployed water rosette for spatially discrete sampling of non-buoyant hydrothermal plumes, or on a fixed mooring in a hydrothermal vent field for time series sampling. It has performed successfully during both its first mooring deployment at the East Pacific Rise and its first remotely-operated vehicle deployments along the Mid-Atlantic Ridge. It is currently capable of rapidly filtering 24 discrete large-water-volume samples (30-100 L per sample) for suspended particles during a single deployment (e.g. >90 L per sample at 4-7 L per minute through 1 {mu}m pore diameter polycarbonate filters). The Suspended Particulate Rosette sampler has been designed with a long-term goal of seafloor observatory deployments, where it can be used to collect samples in response to tectonic or other events. It is compatible with in situ optical sensors, such as laser Raman or visible reflectance spectroscopy systems, enabling in situ particle analysis immediately after sample collection and before the particles alter or degrade.

  18. Measurement of Sub-Picosecond Electron Bunches via Electro-Optic Sampling of Coherent Transition Radiation

    Energy Technology Data Exchange (ETDEWEB)

    Maxwell, Timothy John [Northern Illinois U.

    2012-01-01

    Future collider applications as well as present high-gradient laser plasma wakefield accelerators and free-electron lasers operating with picosecond bunch durations place a higher demand on the time resolution of bunch distribution diagnostics. This demand has led to significant advancements in the field of electro-optic sampling over the past ten years. These methods allow the probing of diagnostic light such as coherent transition radiation or the bunch wakefields with sub-picosecond time resolution. We present results on the single-shot electro-optic spectral decoding of coherent transition radiation from bunches generated at the Fermilab A0 photoinjector laboratory. A longitudinal double-pulse modulation of the electron beam is also realized by transverse beam masking followed by a transverse-to-longitudinal phase-space exchange beamline. Live profile tuning is demonstrated by upstream beam focusing in conjunction with downstream monitoring of single-shot electro-optic spectral decoding of the coherent transition radiation.

  19. Psychometric assessment of the Adult-Adolescent Parenting Inventory in a sample of low-income single mothers.

    Science.gov (United States)

    Lutenbacher, M

    2001-01-01

    The Adult-Adolescent Parenting Inventory (AAPI) is a 32-item inventory widely used to identify adolescents and adults at risk for inadequate parenting behaviors. It includes four subscales representing the most frequent patterns associated with abusive parenting: (a) Inappropriate Expectations; (b) Lack of Empathy; (c) Parental Value of Corporal Punishment; and (d) Parent-Child Role Reversal. Although it has been used in a variety of samples, the psychometric properties of the AAPI have not been examined in low-income single mothers. The purposes of this study were to: (a) examine the reliability and validity of the Adult-Adolescent Parenting Inventory (AAPI) in a sample of 206 low-income single mothers; (b) assess the mother's risk for inadequate parenting by comparing their AAPI subscale scores with normative subscale scores on the AAPI; (c) assess the construct validity of the AAPI by testing the hypothesis that mothers with lower AAPI scores have a higher level of depressive symptoms and lower self-esteem in comparison to mothers with higher AAPI scores; and (d) determine whether the 4-factor structure proposed by Bavolek (1984) could be replicated. AAPI scores indicated these mothers were at high risk for child abuse when compared with normative data for parents with no known history of abuse. Higher risk for abusive parenting was associated with a higher level of depressive symptoms, less education, and unemployment. The subscales, Inappropriate Expectations and Parental Value of Corporal Punishment demonstrated poor internal consistency with Cronbach's alphas of .40 and .54, respectively. Hypothesis testing supported the construct validity of the AAPI. Bavolek's 4-factor structure was not supported. A 19-item modified version of the AAPI with three dimensions was identified. This modified version of the AAPI may provide a more efficacious tool for use with low-income single mothers.

  20. Minutes of the fifth annual meeting of the panel on reference nuclear data

    International Nuclear Information System (INIS)

    Burrows, T.W.; Coyne, J.J.; Brenner, D.S.

    1981-04-01

    The minutes include: approval of agenda and minutes of the fourth meeting; elections; reactor physics data needs; fusion data needs; biomedical data needs; status of international and national cooperation; status and availability of data files; status of transfer of responsibilities from NDP to NNDC; status of publications; on-line data base systems; and summary of recommendations and actions

  1. The elements of grammar in 90 minutes

    CERN Document Server

    Hollander, Robert

    2011-01-01

    An eminent scholar explains the essentials of English grammar to those who never studied the basics as well as those who need a refresher course. Inspired by Strunk & White's classic The Elements of Style, this user-friendly guide focuses exclusively on grammar, explaining the individual parts of speech and their proper arrangement in sentence form. A modest investment of 90 minutes can provide readers of all ages with simple but important tools that will improve their communication skills. Dover (2011) original publication.

  2. Inert gases in a terra sample - Measurements in six grain-size fractions and two single particles from Lunar 20.

    Science.gov (United States)

    Heymann, D.; Lakatos, S.; Walton, J. R.

    1973-01-01

    Review of the results of inert gas measurements performed on six grain-size fractions and two single particles from four samples of Luna 20 material. Presented and discussed data include the inert gas contents, element and isotope systematics, radiation ages, and Ar-36/Ar-40 systematics.

  3. Chernobyl ten years after

    International Nuclear Information System (INIS)

    1996-01-01

    The accident in the fourth reactor plant in Chernobyl in Ukraine occurred ten years years ago, caused the death of 31 people while the health consequences have turned out to be difficult to assess. This review describes the accident, its consequences and effects to health, studies carried out at the present state as well as the comparison with the other accidents and disaster. (author)

  4. FlexED8: the first member of a fast and flexible sample-changer family for macromolecular crystallography.

    Science.gov (United States)

    Papp, Gergely; Felisaz, Franck; Sorez, Clement; Lopez-Marrero, Marcos; Janocha, Robert; Manjasetty, Babu; Gobbo, Alexandre; Belrhali, Hassan; Bowler, Matthew W; Cipriani, Florent

    2017-10-01

    Automated sample changers are now standard equipment for modern macromolecular crystallography synchrotron beamlines. Nevertheless, most are only compatible with a single type of sample holder and puck. Recent work aimed at reducing sample-handling efforts and crystal-alignment times at beamlines has resulted in a new generation of compact and precise sample holders for cryocrystallography: miniSPINE and NewPin [see the companion paper by Papp et al. (2017, Acta Cryst., D73, 829-840)]. With full data collection now possible within seconds at most advanced beamlines, and future fourth-generation synchrotron sources promising to extract data in a few tens of milliseconds, the time taken to mount and centre a sample is rate-limiting. In this context, a versatile and fast sample changer, FlexED8, has been developed that is compatible with the highly successful SPINE sample holder and with the miniSPINE and NewPin sample holders. Based on a six-axis industrial robot, FlexED8 is equipped with a tool changer and includes a novel open sample-storage dewar with a built-in ice-filtering system. With seven versatile puck slots, it can hold up to 112 SPINE sample holders in uni-pucks, or 252 miniSPINE or NewPin sample holders, with 36 samples per puck. Additionally, a double gripper, compatible with the SPINE sample holders and uni-pucks, allows a reduction in the sample-exchange time from 40 s, the typical time with a standard single gripper, to less than 5 s. Computer vision-based sample-transfer monitoring, sophisticated error handling and automatic error-recovery procedures ensure high reliability. The FlexED8 sample changer has been successfully tested under real conditions on a beamline.

  5. ANALGETSKI UCINAK TRANSAKUTNE ELEKTRICNE NERVNE STIMULACIJE (TENS)

    OpenAIRE

    ĆURKOVIĆ, B.

    1984-01-01

    Transkutana električna nervna stimulacija. (TENS) danas je široko prihvaćen terapijski postupak za suzbijanje boli. Način njezina djelovanja nije još jasno definiran, premda se većina autora priklanja centralnom mehranizmu smanjenja boli. Rezultati, u literaturi, variraju od nesignifikantno boljeg učinka od placeba do 95°/o dobrog analgetskog djelovanja. U Zavodu za reumatske bolesti i rehabilitaciju Kliničkog bolničkog centra, Zagreb, evaluiran je učinak TENS-a u bolesnika s križ...

  6. Ignition experiment in a single-turn-coil tokamak

    International Nuclear Information System (INIS)

    Carrera, R.; Driga, M.; Gully, J.H.

    1989-01-01

    A novel concept for a fusion ignition experiment, IGNITEX proposed along the lines of previous ideas for a compact thermonuclear device is analyzed. A single-turn-coil tokamak is analyzed. A single-turn-coil tokamak supplied by homopolar generators can ohmically heat a DT plasma to ignition conditions and maintain a thermally stable ignited phase for about ten energy confinement times. The IGNITEX experiment can provide a simple and relatively inexpensive way to produce and control ignited plasmas for scientific study

  7. Single-pulse and multi-pulse femtosecond laser damage of optical single films

    International Nuclear Information System (INIS)

    Yuan Lei; Zhao Yuan'an; He Hongbo; Shao Jianda; Fan Zhengxiu

    2006-01-01

    Laser-induced damage of a single 500 nm HfO 2 film and a single 500 nm ZrO 2 film were studied with single- and multi-pulse femtosecond laser. The laser-induced damage thresholds (LIDT) of both samples by the 1-on-1 method and the 1000-on-1 method were reported. It was discovered that the LIDT of the HfO 2 single film was higher than that of the ZrO 2 single film by both test methods, which was explained by simple Keldysh's multiphoton ionization theory. The LIDT of multi-pulse was lower than that of single-pulse for both samples as a result of accumulative effect. (authors)

  8. Years of annual ring formation of trees and elements of minute amount

    International Nuclear Information System (INIS)

    Katayama, Yukio

    1988-01-01

    The structure of the trunks of trees is briefly explained, and the effect of environmental factors such as light, rain, soil, temperature and so on and the effect of environmental pollution are conceivable. The examples of the research on the quantitative determination of the elements of minute amount contained in the annual rings of trees and their use as the living things for environmental pollution index are shown, and the problems are considered. The concentration of manganese contained in annual rings may be used as environmental pollution index. It was pointed out that cadmium accumulated in annual rings had a strong correlation with the decrease of annual ring width. K-40 once taken in annual rings moved radially in connection with physical and physiological actions. The authors have examined the distribution of the elements of minute amount in the trunks, using Japanese cedar, white fir and oak as the specimens. For the quantitative analysis of the elements of minute amount, thermal neutron radioactivation analysis was used, which can analyze many elements simultaneously by nondestructive method. The elements of minute amount in the trunks of Japanese cedar, the difference of the distribution according to the kinds of trees, and the movement of elements within trunks are reported. The application of PIXE method to this analysis is considered. (Kako, I.)

  9. Human and bovine enamel erosion under 'single-drink' conditions

    NARCIS (Netherlands)

    White, Andrew J.; Yorath, Celyn; ten Hengel, Valerie; Leary, Sam D.; Huysmans, Marie-Charlotte D. N. J. M.; Barbour, Michele E.

    2010-01-01

    Tooth-surface pH is lowered, during drinking, to a value close to the pH of the drink itself. After the drink is swallowed, the pH rises to baseline values but this process can take several minutes. Few techniques can quantify enamel erosion at timescales representative of single drinks. The

  10. Effects of transcutaneous electrical nerve stimulation (TENS) on arterial stiffness and blood pressure in resistant hypertensive individuals: study protocol for a randomized controlled trial.

    Science.gov (United States)

    Vilela-Martin, José Fernando; Giollo-Junior, Luiz Tadeu; Chiappa, Gaspar Rogério; Cipriano-Junior, Gerson; Vieira, Paulo José Cardoso; dos Santos Ricardi, Fábio; Paz-Landim, Manoel Ildefonso; de Andrade, Days Oliveira; Cestário, Elizabeth do Espírito Santo; Cosenso-Martin, Luciana Neves; Yugar-Toledo, Juan Carlos; Cipullo, José Paulo

    2016-03-29

    Resistant hypertension (RH) treatment requires an adequate and intense therapeutic approach. However, the results are not always satisfactory despite intensive treatment. Of the different pathophysiological mechanisms involved in the pathogenesis of RH, sympathetic overstimulation and therapies that block the sympathetic system have been widely studied. These approaches, however, are invasive and expensive. Another possible approach is by transcutaneous electrical nerve stimulation (TENS), a noninvasive method that modulates activity by using low-frequency transcutaneous electrical stimulation to inhibit primary afferent pathways. Thus, the current study will evaluate the effect of applying TENS in the cervicothoracic region of subjects with RH and will seek to develop a new low-cost and readily available therapy to treat this group of hypertensive individuals. This is a randomized, single blind (subject), parallel-assignment study controlled with a sham group and including participants aged 40 to 70 years with resistant hypertension. The trial has two arms: the treatment and control (sham group). The treatment group will be submitted to the stimulation procedure (TENS). The sham group will not be submitted to stimulation. The primary outcomes will be a reduction in the peripheral blood pressure and adverse events. The secondary outcomes will be a reduction the central blood pressure. The study will last 30 days. The sample size was calculated assuming an alpha error of 5 % to reject the null hypothesis with a statistical power of 80 %, thereby resulting in 28 participants per group (intervention versus sham). In recent decades, RH has become very common and costly. Adequate control requires several drugs, and in many cases, treatment is not successful. Sympathetic nervous system inhibition by renal denervation and central inhibition have significant effects in reducing BP; however, these treatments are costly and invasive. Another type of sympathetic nervous

  11. 40 CFR 1065.595 - PM sample post-conditioning and total weighing.

    Science.gov (United States)

    2010-07-01

    ... minutes before weighing. Note that 400 µg on sample media (e.g., filters) is an approximate net mass of 0... the procedures in § 1065.590(f) through (i) to determine post-test mass of the sample media (e.g., filters). (g) Subtract each buoyancy-corrected tare mass of the sample medium (e.g., filter) from its...

  12. Concurrent validity and reliability of using ground reaction force and center of pressure parameters in the determination of leg movement initiation during single leg lift.

    Science.gov (United States)

    Aldabe, Daniela; de Castro, Marcelo Peduzzi; Milosavljevic, Stephan; Bussey, Melanie Dawn

    2016-09-01

    Postural adjustment evaluations during single leg lift requires the initiation of heel lift (T1) identification. T1 measured by means of motion analyses system is the most reliable approach. However, this method involves considerable workspace, expensive cameras, and time processing data and setting up laboratory. The use of ground reaction forces (GRF) and centre of pressure (COP) data is an alternative method as its data processing and setting up is less time consuming. Further, kinetic data is normally collected using frequency samples higher than 1000Hz whereas kinematic data are commonly captured using 50-200Hz. This study describes the concurrent-validity and reliability of GRF and COP measurements in determining T1, using a motion analysis system as reference standard. Kinematic and kinetic data during single leg lift were collected from ten participants. GRF and COP data were collected using one and two force plates. Displacement of a single heel marker was captured by means of ten Vicon(©) cameras. Kinetic and kinematic data were collected using a sample frequency of 1000Hz. Data were analysed in two stages: identification of key events in the kinetic data, and assessing concurrent validity of T1 based on the chosen key events with T1 provided by the kinematic data. The key event presenting the least systematic bias, along with a narrow 95% CI and limits of agreement against the reference standard T1, was the Baseline COPy event. Baseline COPy event was obtained using one force plate and presented excellent between-tester reliability. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. Sampling and analysis of alien materials in soil

    Energy Technology Data Exchange (ETDEWEB)

    Liphard, K G

    1987-02-01

    For the determination of alien materials in soil, sampling is the decisive step. After minute planning, samples can be obtained by probing, boring or abrasion. Some types of substances can be verified by advance sampling, partly already in the field. Inorganic substances present as anions or cations are eluted and determined with water, heavy metals are determined after preparing a number of solutions by spectroscopic methods. Organic alien substances are extracted with solvents and, as a rule, analysed by chromatography.

  14. Chlorination of irradiated polyethylene single crystals

    International Nuclear Information System (INIS)

    Grimm, H.J.

    1978-01-01

    The chlorination of electron beam-irradiation polyethylene (PE) single crystals was studied for a range of irradiation doses, temperatures, and chlorine interaction times. The results presented show that PE chlorination was quite extensive, even in unirradiated PE single crystals at 25 0 C in the dark. Electron Spin Resonance (ESR, EPR) was used in this study in order to determine the alkyl radical concentration, decay constant, and diffusivity for (unchlorinated) specimens. An alkyl radical diffusivity D/sub a/ = 1.6 x 10 -17 cm 2 /sec at 25 0 C was estimated from ESR data and alkyl radical migration as one-dimensional unsteady-state diffusion process. In irradiated PE, chlorination occurred mainly via chain reactions which were initiated by the irradiation-produced free radicals. Chlorine content values were determined by X-ray Energy Spectroscopy (XES). It was found that the magnitude of the chlorine uptake increased with increasing dose, and decreased with decreasing temperature at constant dose. Otherwise the observed PE chlorination phenomena was quite similar for all of the doses and temperatures studied here, consisting of a two step mechanism: a fast uptake which occurred between time tCl 2 = 0 - 5 minutes and a slower, approximately first-order rate of uptake which occurred between times tCl 2 = 5 - 120 minutes. Chlorination was essentially complete by time tCl 2 = 120 minutes. The rapid uptake probably occurred in the amorphous surface zones where Cl 2 is relatively high and the second, slower step was probably attributable to Cl 2 diffusion into the crystalline regions and subsequent chlorination there. Inasmuch as the PE density decreases with increasing dose (for 1-600 Mrad), Cl 2 diffusivity was enhanced, resulting in higher chlorine uptake values at higher doses

  15. Meeting Report: Minutes from EMBO: Ten Years of Comparative Genomics of Eukaryotic Microorganisms

    Czech Academy of Sciences Publication Activity Database

    Lukeš, Julius; López-García, P.; Louis, E.; Boekhout, T.

    2016-01-01

    Roč. 167, č. 3 (2016), s. 217-221 ISSN 1434-4610 Institutional support: RVO:60077344 Keywords : protist * eukaryotic microorganisms * genomics Subject RIV: EB - Genetics ; Molecular Biology Impact factor: 2.794, year: 2016

  16. Detection of 3-Minute Oscillations in Full-Disk Lyman-alpha Emission During A Solar Flare

    Science.gov (United States)

    Milligan, R. O.; Ireland, J.; Fleck, B.; Hudson, H. S.; Fletcher, L.; Dennis, B. R.

    2017-12-01

    We report the detection of chromospheric 3-minute oscillations in disk-integrated EUV irradiance observations during a solar flare. A wavelet analysis of detrended Lyman-alpha (from GOES/EUVS) and Lyman continuum (from SDO/EVE) emission from the 2011 February 15 X-class flare revealed a 3-minute period present during the flare's main phase. The formation temperature of this emission locates this radiation to the flare's chromospheric footpoints, and similar behaviour is found in the SDO/AIA 1600A and 1700A channels, which are dominated by chromospheric continuum. The implication is that the chromosphere responds dynamically at its acoustic cutoff frequency to an impulsive injection of energy. Since the 3-minute period was not found at hard X-ray energies (50-100 keV) in RHESSI data we can state that this 3-minute oscillation does not depend on the rate of energization of, or energy deposition by, non-thermal electrons. However, a second period of 120 s found in both hard X-ray and chromospheric emission is consistent with episodic electron energization on 2-minute timescales. Our finding on the 3-minute oscillation suggests that chromospheric mechanical energy should be included in the flare energy budget, and the fluctuations in the Lyman-alpha line may influence the composition and dynamics of planetary atmospheres during periods of high activity.

  17. Small-sample-worth perturbation methods

    International Nuclear Information System (INIS)

    1985-01-01

    It has been assumed that the perturbed region, R/sub p/, is large enough so that: (1) even without a great deal of biasing there is a substantial probability that an average source-neutron will enter it; and (2) once having entered, the neutron is likely to make several collisions in R/sub p/ during its lifetime. Unfortunately neither assumption is valid for the typical configurations one encounters in small-sample-worth experiments. In such experiments one measures the reactivity change which is induced when a very small void in a critical assembly is filled with a sample of some test-material. Only a minute fraction of the fission-source neutrons ever gets into the sample and, of those neutrons that do, most emerge uncollided. Monte Carlo small-sample perturbations computations are described

  18. Genotyping of human parvovirus B19 in clinical samples from Brazil and Paraguay using heteroduplex mobility assay, single-stranded conformation polymorphism and nucleotide sequencing

    Directory of Open Access Journals (Sweden)

    Marcos César Lima de Mendonça

    2011-06-01

    Full Text Available Heteroduplex mobility assay, single-stranded conformation polymorphism and nucleotide sequencing were utilised to genotype human parvovirus B19 samples from Brazil and Paraguay. Ninety-seven serum samples were collected from individuals presenting with abortion or erythema infectiosum, arthropathies, severe anaemia and transient aplastic crisis; two additional skin samples were collected by biopsy. After the procedure, all clinical samples were classified as genotype 1.

  19. An in vitro tag-and-modify protein sample generation method for single-molecule fluorescence resonance energy transfer.

    Science.gov (United States)

    Hamadani, Kambiz M; Howe, Jesse; Jensen, Madeleine K; Wu, Peng; Cate, Jamie H D; Marqusee, Susan

    2017-09-22

    Biomolecular systems exhibit many dynamic and biologically relevant properties, such as conformational fluctuations, multistep catalysis, transient interactions, folding, and allosteric structural transitions. These properties are challenging to detect and engineer using standard ensemble-based techniques. To address this drawback, single-molecule methods offer a way to access conformational distributions, transient states, and asynchronous dynamics inaccessible to these standard techniques. Fluorescence-based single-molecule approaches are parallelizable and compatible with multiplexed detection; to date, however, they have remained limited to serial screens of small protein libraries. This stems from the current absence of methods for generating either individual dual-labeled protein samples at high throughputs or protein libraries compatible with multiplexed screening platforms. Here, we demonstrate that by combining purified and reconstituted in vitro translation, quantitative unnatural amino acid incorporation via AUG codon reassignment, and copper-catalyzed azide-alkyne cycloaddition, we can overcome these challenges for target proteins that are, or can be, methionine-depleted. We present an in vitro parallelizable approach that does not require laborious target-specific purification to generate dual-labeled proteins and ribosome-nascent chain libraries suitable for single-molecule FRET-based conformational phenotyping. We demonstrate the power of this approach by tracking the effects of mutations, C-terminal extensions, and ribosomal tethering on the structure and stability of three protein model systems: barnase, spectrin, and T4 lysozyme. Importantly, dual-labeled ribosome-nascent chain libraries enable single-molecule co-localization of genotypes with phenotypes, are well suited for multiplexed single-molecule screening of protein libraries, and should enable the in vitro directed evolution of proteins with designer single-molecule conformational

  20. FIRST SINGLE-PORT LAPAROSCOPIC PANCREATECTOMY IN BRAZIL

    Directory of Open Access Journals (Sweden)

    Marcel Autran Cesar MACHADO

    2013-12-01

    Full Text Available Context Pancreatic surgery is an extremely challenging field, and the management of pancreatic diseases continues to evolve. In the past decade, minimal access surgery is moving towards minimizing the surgical trauma by reducing numbers and size of the port. In the last few years, a novel technique with a single-incision laparoscopic approach has been described for several laparoscopic procedures. Objectives We present a single-port laparoscopic spleen-preserving distal pancreatectomy. To our knowledge, this is the first single-port pancreatic resection in Brazil and Latin America. Methods A 33-year-old woman with neuroendocrine tumor underwent spleen-preserving distal pancreatectomy via single-port approach. A single-incision advanced access platform with gelatin cap, self-retaining sleeve and wound protector was used. Results Operative time was 174 minutes. Blood loss was minimal, and the patient did not receive a transfusion. The recovery was uneventful, and the patient was discharged on postoperative day 4. Conclusions Single-port laparoscopic spleen-preserving distal pancreatectomy is feasible and can be safely performed in specialized centers by skilled laparoscopic surgeons.

  1. How the Big Ten West Was Won: Football Recruiting

    Directory of Open Access Journals (Sweden)

    Diehl Kevin A.

    2017-06-01

    Full Text Available The paper analyses the 2017 Big Ten West Division football cycle models recruiting. The top ten recruit scores [(Rivals.com * 100 + [100 (outside surrounding; 75 (surrounding] + extra credit walk-ons (100; 75] allow proper ranking: Iowa, Nebraska, Wisconsin, Northwestern, Illinois, Minnesota, and Purdue.

  2. Screening for diabetic retinopathy in rural area using single-field, digital fundus images.

    Science.gov (United States)

    Ruamviboonsuk, Paisan; Wongcumchang, Nattapon; Surawongsin, Pattamaporn; Panyawatananukul, Ekchai; Tiensuwan, Montip

    2005-02-01

    To evaluate the practicability of using single-field, 2.3 million-pixel, digital fundus images for screening of diabetic retinopathy in rural areas. All diabetic patients who regularly attended the diabetic clinic at Kabcheang Community Hospital, located at 15 kilometers from the Thailand-Cambodia border, were appointed to the hospital for a 3-day diabetic retinopathy screening programme. The fundi of all patients were captured in single-field, 45 degrees, 2.3 million-pixel images using nonmydriatic digital fundus camera and then sent to a reading center in Bangkok. The fundi were also examined through dilated pupils by a retinal specialist at this hospital. The grading of diabetic retinopathy from two methods was compared for an exact agreement. The average duration of single digital fundus image capture was 2 minutes. The average file size of each image was 750 kilobytes. The average duration of single image transmission to a reading center in Bangkok via satellite was 3 minutes; via a conventional telephone line was 8 minutes. Of all 150 patients, 130 were assessed for an agreement between dilated fundus examination and digital fundus images in diagnosis of diabetic retinopathy. The exact agreement was 0.87, the weighted kappa statistics was 0.74. The sensitivity of digital fundus images in detecting diabetic retinopathy was 80%, the specificity was 96%. For diabetic macular edema the exact agreement was 0.97, the weighted kappa was 0.43, the sensitivity was 43%, and the specificity was 100%. The image capture of the nonmydriatic digital fundus camera is suitable for screening of diabetic retinopathy and single-field digital fundus images are potentially acceptable tools for the screening. The real-time image transmission via telephone lines to remote reading center, however, may not be practical for routine diabetic retinopathy screening in rural areas.

  3. Measurement of the viability of stored red cells by the single-isotope technique using 51Cr. Analysis of validity

    International Nuclear Information System (INIS)

    Beutler, E.; West, C.

    1984-01-01

    A single-isotope 51 Cr method often is used to evaluate the viability of stored red cells. In this technique, the red cell mass is measured by back-extrapolation to time zero (t0) of the radioactivity of the blood between 5 and 20 minutes after infusion of the sample. If there is early destruction of stored cells, this method provides an overestimate of the red cell mass and, hence, of the viability of the stored cells. Freshly drawn red cells from normal donors were labeled with /sup 99m/Tc, and cells from the same donor which had been stored in citrate-phosphate-dextrose-adenine-one (CPDA-1) for periods ranging from 7 to 49 days were labeled with 51 Cr. A comparison of the ''true red cell mass'' as determined with /sup 99m/Tc with the back-extrapolated red cell mass from stored 51 Cr-labeled cells has made it possible to define the magnitude of error introduced by early loss of red cells. The overestimation of red cell mass and viability was diminished if only the 51 Cr radioactivity between 5 and 15 minutes after infusion was used in back-extrapolating to t0. The degree of overestimation of red cell mass was greatest when the red cell viability had declined to very low levels. However, in the entire range of 10 to 80 percent viability, the overestimate of viability was usually less than 4 percent. The overestimate of viability proved to be quite similar for all samples and may be taken into account when using the single-isotope technique for measurement of red cell viability

  4. 2012 Ten-year scheme of network development

    International Nuclear Information System (INIS)

    2012-01-01

    RTE, an independent subsidiary of EDF, is the French electricity transmission system operator. It is a public service company responsible for operating, maintaining and developing the high and extra high voltage network. It guarantees the reliability and proper operation of the power network. RTE transports electricity between electricity suppliers (French and European) and consumers, whether they are electricity distributors or industrial consumers directly connected to the transmission system. The mission of RTE is to balance the electricity supply and demand in real time. With the support of the government authorities, RTE prepares a ten-year scheme of network development in France; This document presents the main electricity transport infrastructures to foresee within the ten coming years and lists the network development investments which must be realised and implemented within 3 years. The document is updated each year and comes to complement at the national level the European ten year network development plan (TYNDP) and the European regional plans as provided for in the 2009/72/CE European directive

  5. Ten-year scheme of network development - 2011

    International Nuclear Information System (INIS)

    2011-01-01

    RTE, an independent subsidiary of EDF, is the French electricity transmission system operator. It is a public service company responsible for operating, maintaining and developing the high and extra high voltage network. It guarantees the reliability and proper operation of the power network. RTE transports electricity between electricity suppliers (French and European) and consumers, whether they are electricity distributors or industrial consumers directly connected to the transmission system. The mission of RTE is to balance the electricity supply and demand in real time. With the support of the government authorities, RTE prepares a ten-year scheme of network development in France; This document presents the main electricity transport infrastructures to foresee within the ten coming years and lists the network development investments which must be realised and implemented within 3 years. The document is updated each year and comes to complement at the national level the European ten year network development plan (TYNDP) and the European regional plans as provided for in the 2009/72/CE European directive

  6. Amount of Minutes Played Does Not Contribute to Anterior Cruciate Ligament Injury in National Basketball Association Athletes.

    Science.gov (United States)

    Okoroha, Kelechi R; Marfo, Kojo; Meta, Fabien; Matar, Robert; Shehab, Ramsy; Thompson, Terry; Moutzouros, Vasilios; Makhni, Eric C

    2017-07-01

    There is limited information on the potential risk factors for sustaining an anterior cruciate ligament (ACL) tear in National Basketball Association (NBA) athletes. This study evaluated 83 NBA players who sustained an ACL injury between 1984 and 2015 to determine the influence of minutes played on injury risk. Minutes played in the injury game, during the season, and over their career were assessed, along with the ability to return to play, player efficiency rating, and playing time after return. Athletes in the NBA played significantly fewer minutes before sustaining an ACL injury (17.1 minutes) than their average minutes per game that season (23.5 minutes; PNBA competition the season following ACL injury. Players who were drafted as lottery picks (draft pick 1 to 15) or those who were starters played significantly more minutes the season following injury than those who were not (both PNBA game did not contribute to the risk of sustaining an ACL injury. Although there was a high rate of return to NBA competition the season following injury, those who were elite athletes played more minutes per game than those who were not. Athletes who returned to play sustained a decrease in player efficiency ratings compared with similar athletes without ACL injury. [Orthopedics. 2017; 40(4):e658-e662.]. Copyright 2017, SLACK Incorporated.

  7. The minute virus of mice exploits different endocytic pathways for cellular uptake

    International Nuclear Information System (INIS)

    Garcin, Pierre O.; Panté, Nelly

    2015-01-01

    The minute virus of mice, prototype strain (MVMp), is a non-enveloped, single-stranded DNA virus of the family Parvoviridae. Unlike other parvoviruses, the mechanism of cellular uptake of MVMp has not been studied in detail. We analyzed MVMp endocytosis in mouse LA9 fibroblasts and a tumor cell line derived from epithelial–mesenchymal transition through polyomavirus middle T antigen transformation in transgenic mice. By a combination of immunofluorescence and electron microscopy, we found that MVMp endocytosis occurs at the leading edge of migrating cells in proximity to focal adhesion sites. By using drug inhibitors of various endocytic pathways together with immunofluorescence microscopy and flow cytometry analysis, we discovered that MVMp can use a number of endocytic pathways, depending on the host cell type. At least three different mechanisms were identified: clathrin-, caveolin-, and clathrin-independent carrier-mediated endocytosis, with the latter occurring in transformed cells but not in LA9 fibroblasts. - Highlights: • MVMp uptake takes place at the leading edge of migrating cells. • MVMp exploits a variety of endocytic pathways. • MVMp could use clathrin- and caveolin-mediated endocytosis. • MVMp could also use clathrin-independent carriers for cellular uptake

  8. The minute virus of mice exploits different endocytic pathways for cellular uptake

    Energy Technology Data Exchange (ETDEWEB)

    Garcin, Pierre O.; Panté, Nelly, E-mail: pante@zoology.ubc.ca

    2015-08-15

    The minute virus of mice, prototype strain (MVMp), is a non-enveloped, single-stranded DNA virus of the family Parvoviridae. Unlike other parvoviruses, the mechanism of cellular uptake of MVMp has not been studied in detail. We analyzed MVMp endocytosis in mouse LA9 fibroblasts and a tumor cell line derived from epithelial–mesenchymal transition through polyomavirus middle T antigen transformation in transgenic mice. By a combination of immunofluorescence and electron microscopy, we found that MVMp endocytosis occurs at the leading edge of migrating cells in proximity to focal adhesion sites. By using drug inhibitors of various endocytic pathways together with immunofluorescence microscopy and flow cytometry analysis, we discovered that MVMp can use a number of endocytic pathways, depending on the host cell type. At least three different mechanisms were identified: clathrin-, caveolin-, and clathrin-independent carrier-mediated endocytosis, with the latter occurring in transformed cells but not in LA9 fibroblasts. - Highlights: • MVMp uptake takes place at the leading edge of migrating cells. • MVMp exploits a variety of endocytic pathways. • MVMp could use clathrin- and caveolin-mediated endocytosis. • MVMp could also use clathrin-independent carriers for cellular uptake.

  9. The Reliability and Validity of a Four-Minute Running Time-Trial in Assessing V˙O2max and Performance

    Directory of Open Access Journals (Sweden)

    Kerry McGawley

    2017-05-01

    Full Text Available Introduction: Traditional graded-exercise tests to volitional exhaustion (GXTs are limited by the need to establish starting workloads, stage durations, and step increments. Short-duration time-trials (TTs may be easier to implement and more ecologically valid in terms of real-world athletic events. The purpose of the current study was to assess the reliability and validity of maximal oxygen uptake (V˙O2max and performance measured during a traditional GXT (STEP and a four-minute running time-trial (RunTT.Methods: Ten recreational runners (age: 32 ± 7 years; body mass: 69 ± 10 kg completed five STEP tests with a verification phase (VER and five self-paced RunTTs on a treadmill. The order of the STEP/VER and RunTT trials was alternated and counter-balanced. Performance was measured as time to exhaustion (TTE for STEP and VER and distance covered for RunTT.Results: The coefficient of variation (CV for V˙O2max was similar between STEP, VER, and RunTT (1.9 ± 1.0, 2.2 ± 1.1, and 1.8 ± 0.8%, respectively, but varied for performance between the three types of test (4.5 ± 1.9, 9.7 ± 3.5, and 1.8 ± 0.7% for STEP, VER, and RunTT, respectively. Bland-Altman limits of agreement (bias ± 95% showed V˙O2max to be 1.6 ± 3.6 mL·kg−1·min−1 higher for STEP vs. RunTT. Peak HR was also significantly higher during STEP compared with RunTT (P = 0.019.Conclusion: A four-minute running time-trial appears to provide more reliable performance data in comparison to an incremental test to exhaustion, but may underestimate V˙O2max.

  10. Top-Ten IT Issues: 2009

    Science.gov (United States)

    Agee, Anne Scrivener; Yang, Catherine

    2009-01-01

    This article presents the top-ten IT-related issues in terms of strategic importance to the institution, as revealed by the tenth annual EDUCAUSE Current Issues Survey. These IT-related issues include: (1) Funding IT; (2) Administrative/ERP Information Systems; (3) Security; (4) Infrastructure/Cyberinfrastructure; (5) Teaching and Learning with…

  11. Evaluation of personal air sampling pumps

    International Nuclear Information System (INIS)

    Ritter, P.D.; Novick, V.J.; Alvarez, J.L.; Huntsman, B.L.

    1987-01-01

    Personal air samplers are used to more conveniently obtain breathing zone samples from individuals over periods of several hours. Personal air sampling pumps must meet minimum performance levels under all working conditions to be suitable for use in radiation protection programs. In addition, the pumps should be simple to operate and as comfortable to wear as possible. Ten models of personal air sampling pumps were tested to evaluate their mechanical performance and physical characteristics. The pumps varied over a wide range in basic performance and operating features. Some of the pumps were found to have adequate performance for use in health physics air sampling applications. 3 references, 2 figures, 5 tables

  12. Exfoliation of Threading Dislocation-Free, Single-Crystalline, Ultrathin Gallium Nitride Nanomembranes

    KAUST Repository

    Elafandy, Rami T.; Cha, Dong Kyu; Majid, Mohammed Abdul; Ng, Tien Khee; Ooi, Boon S.; Zhao, Lan

    2014-01-01

    -efficiency, low-cost, GaN-based heterostructure devices. For the first time, the chemical exfoliation of completely TD-free, single-crystalline, ultrathin (tens of nanometers) GaN nanomembranes is demonstrated using UV-assisted electroless chemical etching

  13. Fabrication of ten-fold photonic quasicrystalline structures

    Directory of Open Access Journals (Sweden)

    XiaoHong Sun

    2015-05-01

    Full Text Available Compared to periodic crystals, quasicrystals have higher point group symmetry and are more favorable in achieving complete band-gaps. In this report, a top-cut prism interferometer is designed to fabricate ten-fold photonic quasicrystalline structures. By optimizing the exposing conditions and material characteristics, appropriate quasicrystals have been obtained in the SU8 photoresist films. Atomic Force Microscopy and laser diffraction are used to characterize the fabricated structures. The measurement results show the consistence between the theoretical design and experiments. This will provide guidance for the large-area and fast production of ten-fold quasicrystalline structures with high quality.

  14. Logs and completion data for water and mass balance wells in Mortandad and Ten Site Canyons

    International Nuclear Information System (INIS)

    McLin, S.G.; Koch, R.J.

    1997-10-01

    Twenty-four monitoring wells were drilled and completed in December 1994 as part of a water and mass balance study for the shallow perched aquifer in the Mortandad Canyon alluvium and in the lower part of Ten-Site Canyon. The wells penetrated the alluvium containing the aquifer and were completed into the top of the weathered tuff. Twelve of these wells encountered the Tshirege Member (Cooing Unit 1 g) of the Bandelier Tuff below the canyon alluvium, while ten wells made contact with the Cerro Toledo interval, which lies between the Tshirege and Otowi Members of the Bandelier Tuff. The remaining two wells were completed into the alluvium above the weathered tuff contact. These wells provide access for continuous water level measurement and water sampling. Data from these new wells will be used to determine changes in alluvial aquifer water storage, water quality sampling, and estimation of seepage into the unsaturated Bandelier Tuff below the alluvium. This report documents drilling activities and well completion logs for the water and mass balance study. These wells also provide critical new data for fourteen north-south vertical cross-sections constructed for the canyon alluvium

  15. A proposal of a standardised nomenclature for terminal minute sister chromatid exchanges

    Directory of Open Access Journals (Sweden)

    Máximo E. Drets

    2006-01-01

    Full Text Available We described spontaneous minute sister chromatid exchanges (SCE in telomeric regions of human and Chinese hamster ovary (CHO chromosomes more than 10 years ago. These structures, which we called t-SCE, were detected by means of highly precise quantitative microphotometrical scanning and computer graphic image analysis. Recently, several authors using the CO-FISH method also found small SCEs in telomeric regions and called them T-SCE. The use of different terms for designating the same phenomenon should be avoided. We propose ter SCE as a uniform nomenclature for minute telomeric SCEs.

  16. Sample preparation for semivolatile organics analysis of Hanford single-shell tank waste with high nitrate/nitrite and water content

    International Nuclear Information System (INIS)

    Stromatt, R.W.; Hoppe, E.W.; Steele, M.J.

    1993-11-01

    This report describes research work carried out to solve sample preparation problems associated with applying gas chromatography with mass spectrometric detection (GC/MS) to the analysis of single shell tank (SST) samples from Hanford for semivolatile organic compounds. Poor performance was found when applying the procedures based on the U.S. Environmental Protection Agency (EPA), Contract Laboratory Program, Statement of Work (CLP SOW). Analysis work was carried out on simulated drainable liquid modeled after the SST core samples which had evidenced analysis problems. Some work was also conducted on true SST samples. It was found that the pH range was too broad in the original procedure. It was also found that by decreasing the amount of methanol used in the extraction process, problems associated with the formation of an azeotrope phase could be avoided. The authors suggest a new procedure, whose eventual application to a wide array of SST samples will lend itself to better quality control limits

  17. Two phase sampling

    CERN Document Server

    Ahmad, Zahoor; Hanif, Muhammad

    2013-01-01

    The development of estimators of population parameters based on two-phase sampling schemes has seen a dramatic increase in the past decade. Various authors have developed estimators of population using either one or two auxiliary variables. The present volume is a comprehensive collection of estimators available in single and two phase sampling. The book covers estimators which utilize information on single, two and multiple auxiliary variables of both quantitative and qualitative nature. Th...

  18. Detection of Three-minute Oscillations in Full-disk Ly α Emission during a Solar Flare

    Energy Technology Data Exchange (ETDEWEB)

    Milligan, Ryan O.; Fletcher, Lyndsay [SUPA, School of Physics and Astronomy, University of Glasgow, Glasgow, G12 8QQ (United Kingdom); Fleck, Bernhard [ESA Directorate of Science, Operations Department, c/o NASA/GSFC Code 671, Greenbelt, MD 20071 (United States); Ireland, Jack; Dennis, Brian R. [Solar Physics Laboratory (Code 671), Heliophysics Science Division, NASA Goddard Space Flight Center, Greenbelt, MD 20771 (United States)

    2017-10-10

    In this Letter we report the detection of chromospheric 3-minute oscillations in disk-integrated EUV irradiance observations during a solar flare. A wavelet analysis of detrended Ly α (from GOES /EUVS) and Lyman continuum (from Solar Dynamics Observatory ( SDO )/EVE) emission from the 2011 February 15 X-class flare (SOL2011-02-15T01:56) revealed a ∼3 minute period present during the flare’s main phase. The formation temperature of this emission locates this radiation at the flare’s chromospheric footpoints, and similar behavior is found in the SDO /Atmospheric Imaging Assembly 1600 and 1700 Å channels, which are dominated by chromospheric continuum. The implication is that the chromosphere responds dynamically at its acoustic cutoff frequency to an impulsive injection of energy. Since the 3-minute period was not found at hard X-ray (HXR) energies (50–100 keV) in Reuven Ramaty High Energy Solar Spectroscopic Imager data we can state that this 3-minute oscillation does not depend on the rate of energization of non-thermal electrons. However, a second period of 120 s found in both HXR and chromospheric lightcurves is consistent with episodic electron energization on 2-minute timescales. Our finding on the 3-minute oscillation suggests that chromospheric mechanical energy should be included in the flare energy budget, and the fluctuations in the Ly α line may influence the composition and dynamics of planetary atmospheres during periods of high activity.

  19. Image of Brazil: similarities and differences in the assessment in ten countries

    Directory of Open Access Journals (Sweden)

    Eber Celoto Souza

    2014-08-01

    Full Text Available This article seeks to understand how foreigners make their image about Brazil and investigates similarities and differences in this assessment. The paper presents the results of a survey of 4373 respondents of ten countries. The authors performed a factor analysis to identify the dimensions and assessment of each country followed by a discriminant analysis. The results indicate that Brazil has a slightly positive image in the sample studied. The affection dimension has the best evaluation, while the communication dimension is the worst, and eight statements have the highest discrimination on the image of Brazil.

  20. Single spin stochastic optical reconstruction microscopy

    OpenAIRE

    Pfender, Matthias; Aslam, Nabeel; Waldherr, Gerald; Wrachtrup, Jörg

    2014-01-01

    We experimentally demonstrate precision addressing of single quantum emitters by combined optical microscopy and spin resonance techniques. To this end we utilize nitrogen-vacancy (NV) color centers in diamond confined within a few ten nanometers as individually resolvable quantum systems. By developing a stochastic optical reconstruction microscopy (STORM) technique for NV centers we are able to simultaneously perform sub diffraction-limit imaging and optically detected spin resonance (ODMR)...

  1. Impedance spectroscopy of tripolar concentric ring electrodes with Ten20 and TD246 pastes.

    Science.gov (United States)

    Nasrollaholhosseini, Seyed Hadi; Herrera, Daniel Salazar; Besio, Walter G

    2017-07-01

    Electrodes are used to transform ionic currents to electrical currents in biological systems. Modeling the electrode-electrolyte interface could help to optimize the performance of the electrode interface to achieve higher signal to noise ratios. There are previous reports of accurate models for single-element biomedical electrodes. In this paper, we measured the impedance on both tripolar concentric ring electrodes and standard cup electrodes by electrochemical impedance spectroscopy (EIS) using both Ten20 and TD246 electrode paste. Furthermore, we applied the model to prove that the model can predict the performance of the electrode-electrolyte interface for tripolar concentric ring electrodes (TCRE) that are used to record brain signals.

  2. A small single-nozzle rainfall simulator to measure erosion response on different burn severities in southern British Columbia, Canada

    Science.gov (United States)

    Covert, Ashley; Jordan, Peter

    2010-05-01

    To study the effects of wildfire burn severity on runoff generation and soil erosion from high intensity rainfall, we constructed an effective yet simple rainfall simulator that was inexpensive, portable and easily operated by two people on steep, forested slopes in southern British Columbia, Canada. The entire apparatus, including simulator, pumps, hoses, collapsible water bladders and sample bottles, was designed to fit into a single full-sized pick-up truck. The three-legged simulator extended to approximately 3.3 metres above ground on steep slopes and used a single Spraying Systems 1/2HH-30WSQ nozzle which can easily be interchanged for other sized nozzles. Rainfall characteristics were measured using a digital camera which took images of the raindrops against a grid. Median drop size and velocity 5 cm above ground were measured and found to be 3/4 of the size of natural rain drops of that diameter class, and fell 7% faster than terminal velocity. The simulator was used for experiments on runoff and erosion on sites burned in 2007 by two wildfires in southern British Columbia. Simulations were repeated one and two years after the fires. Rainfall was simulated at an average rate of 67 mm hr-1 over a 1 m2 plot for 20 minutes. This rainfall rate is similar to the 100 year return period rainfall intensity for this duration at a nearby weather station. Simulations were conducted on five replicate 1 m2 plots in each experimental unit including high burn severity, moderate burn severity, unburned, and unburned with forest floor removed. During the simulation a sample was collected for 30 seconds every minute, with two additional samples until runoff ceased, resulting in 22 samples per simulation. Runoff, overland flow coefficient, infiltration and sediment yield were compared between treatments. Additional simulations were conducted immediately after a 2009 wildfire to test different mulch treatments. Typical results showed that runoff on plots with high burn

  3. Performance enhancement of the single-phase series active filter by employing the load voltage waveform reconstruction and line current sampling delay reduction methods

    DEFF Research Database (Denmark)

    Senturk, O.S.; Hava, A.M.

    2011-01-01

    This paper proposes the waveform reconstruction method (WRM), which is utilized in the single-phase series active filter's (SAF's) control algorithm, in order to extract the load harmonic voltage component of voltage harmonic type single-phase diode rectifier loads. Employing WRM and the line...... current sampling delay reduction method, a single-phase SAF compensated system provides higher harmonic isolation performance and higher stability margins compared to the system using conventional synchronous-reference-frame-based methods. The analytical, simulation, and experimental studies of a 2.5 k...

  4. A Single Molecule Investigation of the Photostability of Quantum Dots

    DEFF Research Database (Denmark)

    Christensen, Eva Arnspang; Kulatunga, Pasad; Lagerholm, B. Christoffer

    2012-01-01

    Quantum dots (QDs) are very attractive probes for multi-color fluorescence applications. We report here however that single QDs that are subject to continuous blue excitation from a 100W mercury arc lamp will undergo a continuous blue-switching of the emission wavelength eventually reaching a per...... is especially detrimental for multi-color single molecule applications, as we regularly observe spectral blue-shifts of 50 nm, or more even after only ten seconds of illumination....

  5. Atrazine analysis using an amperometric immunosensor based on single-chain antibody fragments and regeneration-free multi-calibrant measurement

    International Nuclear Information System (INIS)

    Grennan, Kathleen; Strachan, Gillian; Porter, Andrew J.; Killard, Anthony J.; Smyth, Malcolm R.

    2003-01-01

    This work describes the development of an electrochemical immunosensor for the analysis of atrazine using recombinant single-chain antibody (scAb) fragments. The sensors are based on carbon paste screen-printed electrodes incorporating the conducting polymer polyaniline (PANI)/poly(vinylsulphonic acid) (PVSA), which enables direct mediatorless coupling to take place between the redox centres of antigen-labelled horseradish peroxidase (HRP) and the electrode surface. Competitive immunoassays can be performed in real-time using this separation-free system. Analytical measurements based on the pseudo-linear relationship between the slope of a real-time amperometric signal and the concentration of analyte, yield a novel immunosensor set-up capable of regenerationless amperometric analysis. Multiple, sequential measurements of standards and samples can be performed on a single scAb-modified surface in a matter of minutes. No separation of bound and unbound species was necessary prior to detection. The system is capable of measuring atrazine to a detection limit of 0.1 ppb (0.1 μg l -1 ). This system offers the potential for rapid, cost-effective immunosensing for the analysis of samples of environmental, medical and pharmaceutical significance

  6. Ten into four won't go

    International Nuclear Information System (INIS)

    Freedman, D.Z.; West, P.C.

    1989-01-01

    It is shown that nontrivial spontaneous compactification of ten-dimensional N = 1 supergravity with or without Yang-Mills matter is not possible unless maximal symmetry (i.e. Lorentz invariance) is violated in the four-dimensional spacetime

  7. Critical Studies on Men in Ten European Countries

    DEFF Research Database (Denmark)

    Pringle, Keith; Hearn, Jeff (and 13 other network partners)

    2002-01-01

    This article is one the work of The European Research Network on Men in Europe project “The Social Problem and Societal Problematization of Men and Masculinities” (2000-2003), funded by the European Commission. The Network comprises women and men researchers with range of disciplinary backgrounds...... of statistical sources on men's practices in the ten countries, are presented. This is the second of four articles reviewing critical studies on men in the ten countries through different methods and approaches....

  8. Procedure times, complication rates, and survival times associated with single-chamber versus dual-chamber pacemaker implantation in dogs with clinical signs of bradyarrhythmia: 54 cases (2004-2009).

    Science.gov (United States)

    Genovese, David W; Estrada, Amara H; Maisenbacher, Herbert W; Heatwole, Bonnie A; Powell, Melanie A

    2013-01-15

    To compare procedure times and major and minor complication rates associated with single-chamber versus dual-chamber pacemaker implantation and with 1-lead, 2-lead, and 3-lead pacemaker implantation in dogs with clinical signs of bradyarrhythmia. Retrospective case series. 54 dogs that underwent pacemaker implantation because of clinical signs of bradyarrhythmia. Medical records of dogs that received pacemakers between July 2004 and December 2009 were reviewed for information regarding signalment, diagnosis, pacemaker implantation, pacemaker type, complications, and survival time. Analyses were performed to determine significant differences in anesthesia time, procedure time, and outcome for dogs on the basis of pacing mode and number of pacing leads. 28 of 54 (51.9%) dogs received single-chamber pacemakers and 26 (48.1%) received dual-chamber pacemakers. Mean ± SD procedural time was significantly longer for patients with dual-chamber pacemakers (133.5 ± 51.3 minutes) than for patients with single-chamber pacemakers (94.9 ± 37.0 minutes), and procedure time increased significantly as the number of leads increased (1 lead, 102.3 ± 51.1 minutes; 2 leads, 114.9 ± 24.8 minutes; 3 leads, 158.2 ± 8.5 minutes). Rates of major and minor complications were not significantly different between dogs that received single-chamber pacemakers and those that received dual-chamber pacemakers or among dogs grouped on the basis of the number of pacing leads placed. Although dual-chamber pacemaker implantation did result in increased procedural and anesthesia times, compared with single-chamber pacemaker implantation, this did not result in a higher complication rate.

  9. Nonresponse Error in Mail Surveys: Top Ten Problems

    Directory of Open Access Journals (Sweden)

    Jeanette M. Daly

    2011-01-01

    Full Text Available Conducting mail surveys can result in nonresponse error, which occurs when the potential participant is unwilling to participate or impossible to contact. Nonresponse can result in a reduction in precision of the study and may bias results. The purpose of this paper is to describe and make readers aware of a top ten list of mailed survey problems affecting the response rate encountered over time with different research projects, while utilizing the Dillman Total Design Method. Ten nonresponse error problems were identified, such as inserter machine gets sequence out of order, capitalization in databases, and mailing discarded by postal service. These ten mishaps can potentiate nonresponse errors, but there are ways to minimize their frequency. Suggestions offered stem from our own experiences during research projects. Our goal is to increase researchers' knowledge of nonresponse error problems and to offer solutions which can decrease nonresponse error in future projects.

  10. Flux mapping at 77 K and local measurement at lower temperature of thin-wall YBaCuO single-domain samples oxygenated under high pressure

    Energy Technology Data Exchange (ETDEWEB)

    Chaud, X., E-mail: Xavier.chaud@grenoble.cnrs.f [CRETA, CNRS, 25, Avenue des Martyrs, 38042 Grenoble Cedex 9 (France); Noudem, J. [CRISMAT/ENSICAEN, CNRS, 6 bd Marechal Juin, 14050 Caen (France); Prikhna, T.; Savchuk, Y. [ISM, National Acad. of Sciences of Ukraine, 2 Avtozavodskaya Street, Kiev, 04074 (Ukraine); Haanappel, E. [LNCMP, UMR 5147, 143 avenue de Rangueil, 31400 Toulouse (France); Diko, P. [IEP, Slovak Acad. of Sciences, Watsonova 47, 043 53, Kosice (Slovakia); Zhang, C.P. [SMRC, NIN, 96 Weiyang Road, Xi' an 710016 (China)

    2009-10-15

    YBCO single-domain samples are suitable for the production of high trapped fields in the range 20-77 K using a cryocooler or liquid nitrogen. But the oxygenation process required to actually transform the single domains into superconductors induces an extensive crack network that is limiting the material performances. Thin-wall geometry has been introduced to reduce the diffusion paths and to enable a progressive oxygenation strategy. As a consequence cracks are drastically reduced. In addition the use of a high oxygen pressure (16 MPa) speeds up further the process by displacing the oxygen-temperature equilibrium towards the higher temperature of the phase diagram. The advantage of thin-wall geometry is that such an annealing can be applied directly to a much larger sample. Remarkable results are obtained without any doping by the combination of thin walls and oxygen high pressure. While classical plain samples yield 300-400 mT, a trapped field of 840 mT has been measured at 77 K on a 16 mm diameter Y123 thin-wall single-domain sample with an annealing time as short as 3 days. Local measurements with a fixed Hall probe on top of the sample were performed at lower temperature after magnetization either in a static field or in a pulse field. The trapped field is significantly higher at lower temperature. Cryocoolers become the key to compromise between performances and cryogenic cost around 40 K.

  11. Quantitative echocardiographic measures in the assessment of single ventricle function post-Fontan: Incorporation into routine clinical practice.

    Science.gov (United States)

    Rios, Rodrigo; Ginde, Salil; Saudek, David; Loomba, Rohit S; Stelter, Jessica; Frommelt, Peter

    2017-01-01

    Quantitative echocardiographic measurements of single ventricular (SV) function have not been incorporated into routine clinical practice. A clinical protocol, which included quantitative measurements of SV deformation (global circumferential and longitudinal strain and strain rate), standard deviation of time to peak systolic strain, myocardial performance index (MPI), dP/dT from an atrioventricular valve regurgitant jet, and superior mesenteric artery resistance index, was instituted for all patients with a history of Fontan procedure undergoing echocardiography. All measures were performed real time during clinically indicated studies and were included in clinical reports. A total of 100 consecutive patients (mean age = 11.95±6.8 years, range 17 months-31.3 years) completed the protocol between September 1, 2014 to April 29, 2015. Deformation measures were completed in 100% of the studies, MPI in 93%, dP/dT in 55%, and superior mesenteric artery Doppler in 82%. The studies were reviewed to assess for efficiency in completing the protocol. The average time for image acquisition was 27.4±8.8 (range 10-62 minutes). The average time to perform deformation measures was 10.8±5.5 minutes (range 5-35 minutes) and time from beginning of imaging to report completion was 53.4±13.7 minutes (range 27-107 minutes). There was excellent inter-observer reliability when deformation indices were blindly repeated. Patients with a single left ventricle had significantly higher circumferential strain and strain rate, longitudinal strain and strain rate, and dP/dT compared to a single right ventricle. There were no differences in quantitative indices of ventricular function between patients 10 years post-Fontan. Advanced quantitative assessment of SV function post-Fontan can be consistently and efficiently performed real time during clinically indicated echocardiograms with excellent reliability. © 2016, Wiley Periodicals, Inc.

  12. Design and Evaluation on the Mobile Application of Transcutaneous Electrical Nerve Stimulation (TENS).

    Science.gov (United States)

    Cheng, Ching-Lung; Lee, Li-Hui; Cheng, Yu-Ting

    2017-01-01

    This study aims to design a transcutaneous electrical nerve stimulation Application (TENS App) according to the suggestions from potential users. To the best of our knowledge, this is the first App including meridian and acupoints for TENS. After its development, there are eight participants recruited for evaluating the usability. Despite two out of eight users reporting that the typical TENS system requires lower cost and has better functionality than TENS App, the results show that almost seventy percent of participants have a better perception of TENS App on price, functionality, convenience, operational ability, and quality. However, participants still reported concerns about the safety issue of adopting TENS App. Therefore, for people who are the first time or unfamiliar with TENS App, instructions from occupational or physical therapists are recommended. We conclude that by using TENS App, users can not only use the portable electrotherapy devices at anyplace, but also reduce their outpatient visits.

  13. Spectrally resolved single-molecule electrometry

    Science.gov (United States)

    Ruggeri, F.; Krishnan, M.

    2018-03-01

    Escape-time electrometry is a recently developed experimental technique that offers the ability to measure the effective electrical charge of a single biomolecule in solution with sub-elementary charge precision. The approach relies on measuring the average escape-time of a single charged macromolecule or molecular species transiently confined in an electrostatic fluidic trap. Comparing the experiments with the predictions of a mean-field model of molecular electrostatics, we have found that the measured effective charge even reports on molecular conformation, e.g., folded or disordered state, and non-uniform charge distribution in disordered proteins or polyelectrolytes. Here we demonstrate the ability to use the spectral dimension to distinguish minute differences in electrical charge between individual molecules or molecular species in a single simultaneous measurement, under identical experimental conditions. Using one spectral channel for referenced measurement, this kind of photophysical distinguishability essentially eliminates the need for accurate knowledge of key experimental parameters, otherwise obtained through intensive characterization of the experimental setup. As examples, we demonstrate the ability to detect small differences (˜5%) in the length of double-stranded DNA fragments as well as single amino acid exchange in an intrinsically disordered protein, prothymosin α.

  14. Single-edition quadrangle maps

    Science.gov (United States)

    ,

    1998-01-01

    In August 1993, the U.S. Geological Survey's (USGS) National Mapping Division and the U.S. Department of Agriculture's Forest Service signed an Interagency Agreement to begin a single-edition joint mapping program. This agreement established the coordination for producing and maintaining single-edition primary series topographic maps for quadrangles containing National Forest System lands. The joint mapping program saves money by eliminating duplication of effort by the agencies and results in a more frequent revision cycle for quadrangles containing national forests. Maps are revised on the basis of jointly developed standards and contain normal features mapped by the USGS, as well as additional features required for efficient management of National Forest System lands. Single-edition maps look slightly different but meet the content, accuracy, and quality criteria of other USGS products. The Forest Service is responsible for the land management of more than 191 million acres of land throughout the continental United States, Alaska, and Puerto Rico, including 155 national forests and 20 national grasslands. These areas make up the National Forest System lands and comprise more than 10,600 of the 56,000 primary series 7.5-minute quadrangle maps (15-minute in Alaska) covering the United States. The Forest Service has assumed responsibility for maintaining these maps, and the USGS remains responsible for printing and distributing them. Before the agreement, both agencies published similar maps of the same areas. The maps were used for different purposes, but had comparable types of features that were revised at different times. Now, the two products have been combined into one so that the revision cycle is stabilized and only one agency revises the maps, thus increasing the number of current maps available for National Forest System lands. This agreement has improved service to the public by requiring that the agencies share the same maps and that the maps meet a

  15. Tibetan tectonics from 40Ar/39Ar analysis of a single K-feldspar sample

    International Nuclear Information System (INIS)

    Richter, F.M.; Lovera, O.M.; Harrison, T.M.; Copeland, P.

    1991-01-01

    40 Ar/ 39 Ar data on an alkali feldspar sample from the Quxu pluton, Gangdese batholith, southern Tibet, allow a detailed assessment of unroofing and uplift history between 35 and 18 Ma. The 39 Ar Arrhenius plot for this sample shows departures from a linear relationship between the effective diffusion parameter, log(D/r 2 ), and reciprocal temperature, which we interpret to be the result of a distribution of distinct diffusion-domain sizes. We use an alternative way of plotting the Arrhenius data that exhibits domain size versus cumulative % 39 Ar released during step heating. The 40 Ar/ 39 Ar age spectrum of the sample has features, such as local age plateaus, that are most easily explained in terms of the distinctive closure age of particular domains. The fact that the same distribution of diffusion-domain sizes explains both the Arrhenius data and the age spectrum is an indication that the diffusion properties operating in the laboratory are those of the sample while it was in its natural environment. Modelling of the age spectrum with a distribution of domain sizes results in the recovery of a continuous cooling-history segment rather than a single time-temperature datum. We demonstrate the robustness of the cooling-curve determination by showing the large misfits to the age spectrum that arise from relatively small changes in the cooling history. The best-fit cooling curve for the Quxu sample shows a decreasing rate of cooling in the time interval 35-18 Ma, followed by a very rapid cooling beginning at about 18 Ma. We have used a thermal model for the conductive cooling of an unroofing pluton to estimate the rate of unroofing required to explain the Quxu cooling curve, and find that in the 35-20 Ma time interval, the primary control of the thermal evolution is the conductive loss of magmatic heat with little or no unroofing (unroofing rates of approximately 0.05 mm/yr) followed by a brief period (<5 Ma) of very rapid unroofing with rates of order 2 mm

  16. Programmable lab-on-a-chip system for single cell analysis

    Science.gov (United States)

    Thalhammer, S.

    2009-05-01

    The collection, selection, amplification and detection of minimum genetic samples became a part of everyday life in medical and biological laboratories, to analyze DNA-fragments of pathogens, patient samples and traces on crime scenes. About a decade ago, a handful of researchers began discussing an intriguing idea. Could the equipment needed for everyday chemistry and biology procedures be shrunk to fit on a chip in the size of a fingernail? Miniature devices for, say, analysing DNA and proteins should be faster and cheaper than conventional versions. Lab-on-a-chip is an advanced technology that integrates a microfluidic system on a microscale chip device. The "laboratory" is created by means of channels, mixers, reservoirs, diffusion chambers, integrated electrodes, pumps, valves and more. With lab-ona- chip technology, complete laboratories on a square centimetre can be created. Here, a multifunctional programmable Lab-on-a-Chip driven by nanofluidics and controlled by surface acoustic waves (SAW) is presented. This system combines serial DNA-isolation-, amplification- and array-detection-process on a modified glass-platform. The fluid actuation is controlled via SAW by interdigital transducers implemented in the chemical modified chip surface. The chemical surface modification allows fluid handling in the sub-microliter range. Minute amount of sample material is extracted by laser-based microdissection out of e.g. histological sections at the single cell level. A few picogram of genetic material are isolated and transferred via a low-pressure transfer system (SPATS) onto the chip. Subsequently the genetic material inside single droplets, which behave like "virtual" beaker, is transported to the reaction and analysis centers on the chip surface via surface acoustic waves, mainly known as noise dumping filters in mobile phones. At these "biological reactors" the genetic material is processed, e.g. amplified via polymerase chain reaction methods, and genetically

  17. Flexible single molecule simulation of reaction-diffusion processes

    International Nuclear Information System (INIS)

    Hellander, Stefan; Loetstedt, Per

    2011-01-01

    An algorithm is developed for simulation of the motion and reactions of single molecules at a microscopic level. The molecules diffuse in a solvent and react with each other or a polymer and molecules can dissociate. Such simulations are of interest e.g. in molecular biology. The algorithm is similar to the Green's function reaction dynamics (GFRD) algorithm by van Zon and ten Wolde where longer time steps can be taken by computing the probability density functions (PDFs) and then sample from the distribution functions. Our computation of the PDFs is much less complicated than GFRD and more flexible. The solution of the partial differential equation for the PDF is split into two steps to simplify the calculations. The sampling is without splitting error in two of the coordinate directions for a pair of molecules and a molecule-polymer interaction and is approximate in the third direction. The PDF is obtained either from an analytical solution or a numerical discretization. The errors due to the operator splitting, the partitioning of the system, and the numerical approximations are analyzed. The method is applied to three different systems involving up to four reactions. Comparisons with other mesoscopic and macroscopic models show excellent agreement.

  18. Single-injection method for evaluation of renal function with 14C-inulin and 3H-tetraethylammonium bromide in dogs and cats

    International Nuclear Information System (INIS)

    Fettman, M.J.; Allen, T.A.; Wilke, W.L.; Radin, M.J.; Eubank, M.C.

    1985-01-01

    A double-isotope single-injection method without urine collection for the estimation of glomerular filtration rate (GFR) and effective renal plasma flow (ERPF) in dogs and cats was evaluated. The GFR was determined, using 14 C-inulin and ERPF was determined, using [ 3 H]tetraethylammonium bromide. Using a modified single exponential, 1-compartment mathematical model, the renal clearance of these solutes was estimated with a plasma radioactivity disappearance curve constructed from samples collected over a 150-minute time period. In 25 dogs, GFR, ERPF, and filtration fraction were 3.55 +/- 0.14 ml/kg/min, 10.51 +/- 0.72 ml/kg/min, and 0.34 +/- 0.02, respectively. In 25 cats, GFR, ERPF, and filtration fraction were 3.24 +/- 0.14 ml/kg/min, 8.14 +/- 0.53 ml/kg/min, and 0.39 +/- 0.02, respectively. This time-efficient and reliable method, using beta-emitting isotopes, yielded renal functional values well within the normal ranges reported by a variety of other isotopic and nonisotopic procedures. The advantages of the present procedure over previous double-isotope single-injection methods include the use of less costly, lower energy-using, and less penetrating beta emittors, as well as a shortened blood sampling schedule

  19. Single-nanotube tracking reveals the nanoscale organization of the extracellular space in the live brain

    Science.gov (United States)

    Godin, Antoine G.; Varela, Juan A.; Gao, Zhenghong; Danné, Noémie; Dupuis, Julien P.; Lounis, Brahim; Groc, Laurent; Cognet, Laurent

    2017-03-01

    The brain is a dynamic structure with the extracellular space (ECS) taking up almost a quarter of its volume. Signalling molecules, neurotransmitters and nutrients transit via the ECS, which constitutes a key microenvironment for cellular communication and the clearance of toxic metabolites. The spatial organization of the ECS varies during sleep, development and aging and is probably altered in neuropsychiatric and degenerative diseases, as inferred from electron microscopy and macroscopic biophysical investigations. Here we show an approach to directly observe the local ECS structures and rheology in brain tissue using super-resolution imaging. We inject single-walled carbon nanotubes into rat cerebroventricles and follow the near-infrared emission of individual nanotubes as they diffuse inside the ECS for tens of minutes in acute slices. Because of the interplay between the nanotube geometry and the ECS local environment, we can extract information about the dimensions and local viscosity of the ECS. We find a striking diversity of ECS dimensions down to 40 nm, and as well as of local viscosity values. Moreover, by chemically altering the extracellular matrix of the brains of live animals before nanotube injection, we reveal that the rheological properties of the ECS are affected, but these alterations are local and inhomogeneous at the nanoscale.

  20. Improved Synthesis of Global Irradiance with One-Minute Resolution for PV System Simulations

    Directory of Open Access Journals (Sweden)

    Martin Hofmann

    2014-01-01

    Full Text Available High resolution global irradiance time series are needed for accurate simulations of photovoltaic (PV systems, since the typical volatile PV power output induced by fast irradiance changes cannot be simulated properly with commonly available hourly averages of global irradiance. We present a two-step algorithm that is capable of synthesizing one-minute global irradiance time series based on hourly averaged datasets. The algorithm is initialized by deriving characteristic transition probability matrices (TPM for different weather conditions (cloudless, broken clouds and overcast from a large number of high resolution measurements. Once initialized, the algorithm is location-independent and capable of synthesizing one-minute values based on hourly averaged global irradiance of any desired location. The one-minute time series are derived by discrete-time Markov chains based on a TPM that matches the weather condition of the input dataset. One-minute time series generated with the presented algorithm are compared with measured high resolution data and show a better agreement compared to two existing synthesizing algorithms in terms of temporal variability and characteristic frequency distributions of global irradiance and clearness index values. A comparison based on measurements performed in Lindenberg, Germany, and Carpentras, France, shows a reduction of the frequency distribution root mean square errors of more than 60% compared to the two existing synthesizing algorithms.

  1. Mid-term evaluation of ten National Research schools

    DEFF Research Database (Denmark)

    Gustafsson, Göran; Dahl, Hanne Marlene; Gustafsson, Christina

    the scheme was launched, the Research Council has issued three calls for proposals and allocated grants to a total of 22 national research schools. Five were started up in 2009, ten in 2013 and seven in 2015. A Nordic scientific programme committee was appointed in 2013, with responsibility for assessing...... grant applications, monitoring the progress of the FORSKERSKOLER scheme and serving as the evaluation panel for the mid-term evaluation in 2013 and in 2016/2017. The task of the evaluation panel has been to: 1) evaluate the quality of and progress achieved by the ten research schools which were awarded...... funding in 2012 and launched in 2013; and 2) to provide recommendations as to whether funding should be continued to cover the full eight-year period or terminated after five years. Continued funding is recommended for all ten schools to cover the full eight-year period, according to the proposed budget...

  2. Is TENS purely a placebo effect? A controlled study on chronic low back pain.

    Science.gov (United States)

    Marchand, S; Charest, J; Li, J; Chenard, J R; Lavignolle, B; Laurencelle, L

    1993-07-01

    Although high-frequency low-intensity transcutaneous electric nerve stimulation (TENS) has been extensively used to relieve low back pain, experimental studies of its effectiveness have yielded contradictory findings mainly due to methodological problems in pain evaluation and placebo control. In the present study, separate visual analog scales (VAS) were used to measure the sensory-discriminative and motivational-affective components of low back pain. Forty-two subjects were randomly assigned to 1 of 3 groups: TENS, placebo-TENS, and no treatment (control). In order to measure the short-term effect of TENS, VAS pain ratings were taken before and after each treatment session. Also, to measure long-term effects, patients rated their pain at home every 2 h throughout a 3-day period before and 1 week, 3 months and 6 months after the treatment sessions. In comparing the pain evaluations made immediately before and after each treatment session, TENS and placebo-TENS significantly reduced both the intensity and unpleasantness of chronic low back pain. TENS was significantly more efficient than placebo-TENS in reducing pain intensity but not pain unpleasantness. TENS also produced a significant additive effect over repetitive treatment sessions for pain intensity and relative pain unpleasantness. This additive effect was not found for placebo-TENS. When evaluated at home, pain intensity was significantly reduced more by TENS than placebo-TENS 1 week after the end of treatment, but not 3 months and 6 months later. At home evaluation of pain unpleasantness in the TENS group was never different from the placebo-TENS group.(ABSTRACT TRUNCATED AT 250 WORDS)

  3. A single reagent radioimmunoassay for thyroxine in blood samples absorbed on filter paper for mass screening of neonatal hypothyroidism

    International Nuclear Information System (INIS)

    Nair, N.; Pillai, M.R.A.; Mani, R.S.

    1988-01-01

    A single reagent radioimmunoassay for thyroxine in blood samples absorbed on filter paper for the mass screening of neonatal hypothyroidism is described. Blood samples were collected by pricking the heel of newborn babies (3 days old) and pressing Whatman 3 filter paper against the wound. 6 mm diameter blood spots were punched out at the time of assay and incubated with 0.4 ml of a preincubated antigen-antibody complex for six hours at 37 deg C. 1 ml of 22% polyethylene glycol is used for the precipitation of antigen-antibody complex. The assay has a sensitivity of 2.2 ng/ml. 500 samples collected from newborns were analyzed in the assay and gave a mean of 117.6+-31.9 ng/ml. (author) 9 refs.; 4 figs

  4. Hot topic: Bovine milk samples yielding negative or nonspecific results in bacterial culturing--the possible role of PCR-single strand conformation polymorphism in mastitis diagnosis.

    Science.gov (United States)

    Schwaiger, K; Wimmer, M; Huber-Schlenstedt, R; Fehlings, K; Hölzel, C S; Bauer, J

    2012-01-01

    A large proportion of mastitis milk samples yield negative or nonspecific results (i.e., no mastitis pathogen can be identified) in bacterial culturing. Therefore, the culture-independent PCR-single strand conformation polymorphism method was applied to the investigation of bovine mastitis milk samples. In addition to the known mastitis pathogens, the method was suitable for the detection of fastidious bacteria such as Mycoplasma spp., which are often missed by conventional culturing methods. The detection of Helcococcus ovis in 4 samples might indicate an involvement of this species in pathogenesis of bovine mastitis. In conclusion, PCR-single-strand conformation polymorphism is a promising tool for gaining new insights into the bacteriological etiology of mastitis. Copyright © 2012 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  5. Expanding Educators' Medical Curriculum Tool Chest: Minute Papers as an Underutilized Option for Obtaining Immediate Feedback

    Science.gov (United States)

    Singh, Mamta K.; Lawrence, Renée; Headrick, Linda

    2011-01-01

    Background One barrier to systematically assessing feedback about the content or format of teaching conferences in graduate medical education is the time needed to collect and analyze feedback data. Minute papers, brief surveys designed to obtain feedback in a concise format, have the potential to fill this gap. Objectives To assess whether minute papers were a feasible tool for obtaining immediate feedback on resident conferences and to use minute papers, with one added question, to assess the usefulness of changing the format of resident morning report. Methods Minute papers were administered at the end of internal medicine morning report conferences before and after changing the traditional combined format (all residents) to a separate format (postgraduate year [PGY] 1 met separately from PGY-2 and PGY-3 trainees). We collected information during 3 months during 2 traditional sessions and 8 sessions in the format that separated PGY-1s (3 for PGY-1 and 5 for PGY-2 and PGY-3). Participants responded to an item rating the usefulness of the session and 3 open-ended questions. Results Trainees completed the forms in 2 to 3 minutes. Trainee assessment of the usefulness of internal medicine morning report appeared to increase after the change (4.09 versus 4.45 for PGY-1; 3.75 versus 4.38 for PGY-2 and PGY-3 residents). Conclusions Minute papers are practical instruments that provide manageable amounts of immediate feedback. In addition, minute papers can be adjusted slightly to help assess the impact of change. In that way, faculty can create an iterative process of feedback that models small cycles of change, a key quality improvement concept. PMID:22655149

  6. Ten out of ten for LHC decapole magnets

    CERN Multimedia

    2001-01-01

    CERN's Albert Ijspeert (left) and Avinash Puntambekar of the Indian CAT laboratory with the ten Indian decapole magnets on the test bench. Tests will be carried out by the LHC-MTA group. A batch of 10 superconducting decapole magnets for the LHC has just arrived at CERN from India. These will be used to correct for slight imperfections in the dipole magnets that will steer proton beams around CERN's new accelerator. All magnets have slight imperfections in the fields they produce, and in the LHC dipoles these will be corrected for using sextupoles and decapoles. The sextupoles were the first LHC magnets to be given the production green-light following successful tests of pre-series magnets last year (Bulletin 21/2000, 22 May 2000). Now it is the turn of pre-series decapoles to go on trial at CERN. Of the LHC's 1232 dipole magnets, half will use sextupole correctors only and the other half will use both sextupoles and decapoles. That means that a total of 616 pairs of decapoles are needed. Like the sextupole...

  7. Effect of irradiation on total chemical profiles of ten selected local herbs

    International Nuclear Information System (INIS)

    Salmah Moosa; Maizatul Akmam Mohd Nasir

    2010-01-01

    As utilisation of medicinal herbs in food and bio industry increases, mass production and the supply of high quality herbs are required. Restriction on the use of fumigants and preservatives on herbs demands safe hygienic technologies such as irradiation. The stability of the active components of ten local herbs after irradiation was studied. The herbs selected were Hempedu Bumi, Mas Cotek, Tongkat Ali, Kacip Fatimah, Misai Kucing, Dukung Anak, Jarum Tujuh Bilah, Kesom, Pegaga and Sambung Nyawa. The herbs were dried, powdered and irradiated at different doses of gamma radiation (0, 1, 3, 5, 10, 15 and 25 kGy) at room temperature prior to extraction. The herbs were then extracted either in methanol or chloroform and freeze dried. About 10.0 mg of each extract (in triplicates) were weighed into an Eppendorf vial and solubilised in 700 μl CD 3 OD using sonication in an ultrasound bath to obtain a clear solution. This solution was then transferred to a NMR vial and a 1H-NMR spectrum was acquired according to standard Total Quality Profile (TQP) protocol. The results of the statistical analysis showed clearly that all irradiated plant samples did not exhibit any significant pattern of differences. Using SIMCA analysis, we found that there is no statistical basis for separation of control, 1, 5, 10, 15 and 25 kGy irradiated samples on a 95 % confidence limit. TQP analysis for the ten selected herbal plant shows that irradiation up to 25 kGy did not cause significant changes to the total chemical profiles and thus the integrity of the herbal material in the analysed plants. (author)

  8. SUPERAÇÃO DE DORMÊNCIA EM SEMENTES DE JITIRANA ( Merremia aegyptia L.

    Directory of Open Access Journals (Sweden)

    Elaíne Welk Lopes Pereira

    2007-01-01

    Full Text Available The objective of work was evaluated four methods of superation of dormancy in Jitirana (Merremia aegyptia. The treatments used were: 1- Checking, 2 - Submersion in the hot water at 80ºC by one minute, 3 - Mechanic escarification by five minutes; 4 - Submersion in the sulfuric acid by six minutes, 5 - Submersion in the sulfuric acid by ten minutes. The experimental design was completely randomized with four replications. The plot was formed by sample with 50 seeds. The traits evaluated were: fresh weight, dry weight, height of seedling, length of root, percentage of germination and index of velocity of germination. The seeds treated with sulfuric acid showed bigger percentage of germination. The treatments with mechanic escarification and sulfuric acid (10 minutes showed bigger index of velocity of germination.

  9. MPLEx: a Robust and Universal Protocol for Single-Sample Integrative Proteomic, Metabolomic, and Lipidomic Analyses

    Energy Technology Data Exchange (ETDEWEB)

    Nakayasu, Ernesto S.; Nicora, Carrie D.; Sims, Amy C.; Burnum-Johnson, Kristin E.; Kim, Young-Mo; Kyle, Jennifer E.; Matzke, Melissa M.; Shukla, Anil K.; Chu, Rosalie K.; Schepmoes, Athena A.; Jacobs, Jon M.; Baric, Ralph S.; Webb-Robertson, Bobbie-Jo; Smith, Richard D.; Metz, Thomas O.; Chia, Nicholas

    2016-05-03

    ABSTRACT

    Integrative multi-omics analyses can empower more effective investigation and complete understanding of complex biological systems. Despite recent advances in a range of omics analyses, multi-omic measurements of the same sample are still challenging and current methods have not been well evaluated in terms of reproducibility and broad applicability. Here we adapted a solvent-based method, widely applied for extracting lipids and metabolites, to add proteomics to mass spectrometry-based multi-omics measurements. Themetabolite,protein, andlipidextraction (MPLEx) protocol proved to be robust and applicable to a diverse set of sample types, including cell cultures, microbial communities, and tissues. To illustrate the utility of this protocol, an integrative multi-omics analysis was performed using a lung epithelial cell line infected with Middle East respiratory syndrome coronavirus, which showed the impact of this virus on the host glycolytic pathway and also suggested a role for lipids during infection. The MPLEx method is a simple, fast, and robust protocol that can be applied for integrative multi-omic measurements from diverse sample types (e.g., environmental,in vitro, and clinical).

    IMPORTANCEIn systems biology studies, the integration of multiple omics measurements (i.e., genomics, transcriptomics, proteomics, metabolomics, and lipidomics) has been shown to provide a more complete and informative view of biological pathways. Thus, the prospect of extracting different types of molecules (e.g., DNAs, RNAs, proteins, and metabolites) and performing multiple omics measurements on single samples is very attractive, but such studies are challenging due to the fact that the extraction conditions differ according to the molecule type. Here, we adapted an organic solvent-based extraction method that demonstrated

  10. Rheological Characterization of Unusual DWPF Slurry Samples

    International Nuclear Information System (INIS)

    Koopman, D. C.

    2005-01-01

    A study was undertaken to identify and clarify examples of unusual rheological behavior in Defense Waste Processing Facility (DWPF) simulant slurry samples. Identification was accomplished by reviewing sludge, Sludge Receipt and Adjustment Tank (SRAT) product, and Slurry Mix Evaporator (SME) product simulant rheological results from the prior year. Clarification of unusual rheological behavior was achieved by developing and implementing new measurement techniques. Development of these new methods is covered in a separate report, WSRC-TR-2004-00334. This report includes a review of recent literature on unusual rheological behavior, followed by a summary of the rheological measurement results obtained on a set of unusual simulant samples. Shifts in rheological behavior of slurries as the wt. % total solids changed have been observed in numerous systems. The main finding of the experimental work was that the various unusual DWPF simulant slurry samples exhibit some degree of time dependent behavior. When a given shear rate is applied to a sample, the apparent viscosity of the slurry changes with time rather than remaining constant. These unusual simulant samples are more rheologically complex than Newtonian liquids or more simple slurries, neither of which shows significant time dependence. The study concludes that the unusual rheological behavior that has been observed is being caused by time dependent rheological properties in the slurries being measured. Most of the changes are due to the effect of time under shear, but SB3 SME products were also changing properties while stored in sample bottles. The most likely source of this shear-related time dependence for sludge is in the simulant preparation. More than a single source of time dependence was inferred for the simulant SME product slurries based on the range of phenomena observed. Rheological property changes were observed on the time-scale of a single measurement (minutes) as well as on a time scale of hours

  11. Defining an optimum pumping-time requirement for sampling ground-water wells on the Hanford site

    International Nuclear Information System (INIS)

    Scharnhorst, N.L.

    1982-04-01

    The objective was to determine the optimum time period necessary to pump water from a well before a representative sample of the ground water can be obtained. It was assumed that a representative sample has been collected if the concentration of chemical parameters is the same in a number of samples taken consecutively, so that the concentration of parameters does not vary with time of collection. Ground-water samples used in this project were obtained by pumping selected wells on the Hanford Site. At each well, samples were taken at two minute intervals, and on each sample various chemical analyses were performed. Samples were checked for pH, sulfate, iron, specific conductivity, chloride, nitrate and alkalinity. The data showed that pH, alkalinity, sulfate and specific conductivity levels stabilized almost immediately after pumping of the well began. In many wells, the chloride and nitrate levels were unstable throughout the 38-minute sampling period. Iron levels, however, did not behave in either fashion. The concentration of iron in the samples was high when pumping began but dropped rapidly as pumping continued. The best explanation for this is that iron is flushed from the sides of the casing into the well when pumping begins. After several minutes of pumping, most of the dissolved iron is washed from the well casing and the iron concentration reaches a stable plateau representative of the iron concentration in the ground water.Since iron concentration takes longest to stabilize, the optimum pumping time for a well is based on the iron stabilization time for that well

  12. LEARNING CURVE IN SINGLE-LEVEL MINIMALLY INVASIVE TLIF: EXPERIENCE OF A NEUROSURGEON

    Directory of Open Access Journals (Sweden)

    Samuel Romano-Feinholz

    Full Text Available ABSTRACT Objective: To describe the learning curve that shows the progress of a single neurosurgeon when performing single-level MI-TLIF. Methods: We included 99 consecutive patients who underwent single-level MI-TLIF by the same neurosurgeon (JASS. Patient’s demographic characteristics were analyzed. In addition, surgical time, intraoperative blood loss and hospital stay were evaluated. The learning curves were calculated with a piecewise regression model. Results: The mean age was 54.6 years. The learning curves showed an inverse relationship between the surgical experience and the variable analyzed, reaching an inflection point for surgical time in case 43 and for blood loss in case 48. The mean surgical time was 203.3 minutes (interquartile range [IQR] 150-240 minutes, intraoperative bleeding was 97.4ml (IQR 40-100ml and hospital stay of four days (IQR 3-5 days. Conclusions: MI-TLIF is a very frequent surgical procedure due to its effectiveness and safety, which has shown similar results to open procedure. According to this study, the required learning curve is slightly higher than for open procedures, and is reached after about 45 cases.

  13. Ten years after the Jali Commission

    African Journals Online (AJOL)

    Ten years have lapsed since the Jali Commission's final report became publicly available, and it is therefore an .... as the 'core business' of the department. This was seen as .... the 2009/10–2013/14 DCS Strategic Plan did the department ...

  14. Surficial geology of the Cabot 7 1/2 minute quadrangle, Vermont

    Data.gov (United States)

    Vermont Center for Geographic Information — Digital data from VG2016-3 Springston, G., 2016, Surficial geology of the Cabot 7 1/2 minute quadrangle, Vermont:�Vermont Geological Survey Open File Report...

  15. Coal industry - minutes of evidence - Wednesday 14 May 1986. [United Kingdom

    Energy Technology Data Exchange (ETDEWEB)

    1986-01-01

    The paper contains minutes of evidence on the coal industry from the examination of witnesses from Associated Heat Services PLC, Boots PLC, the chamber of Coal Trades and the Domestic Coal Consumers' Council.

  16. Single-stage revision for fungal peri-prosthetic joint infection: a single-centre experience.

    Science.gov (United States)

    Klatte, T O; Kendoff, D; Kamath, A F; Jonen, V; Rueger, J M; Frommelt, L; Gebauer, M; Gehrke, T

    2014-04-01

    Fungal peri-prosthetic infections of the knee and hip are rare but likely to result in devastating complications. In this study we evaluated the results of their management using a single-stage exchange technique. Between 2001 and 2011, 14 patients (ten hips, four knees) were treated for a peri-prosthetic fungal infection. One patient was excluded because revision surgery was not possible owing to a large acetabular defect. One patient developed a further infection two months post-operatively and was excluded from the analysis. Two patients died of unrelated causes. After a mean of seven years (3 to 11) a total of ten patients were available for follow-up. One patient, undergoing revision replacement of the hip, had a post-operative dislocation. Another patient, undergoing revision replacement of the knee, developed a wound infection and required revision 29 months post-operatively following a peri-prosthetic femoral fracture. The mean Harris hip score increased to 74 points (63 to 84; p prosthetic infection is feasible, with an acceptable rate of a satisfactory outcome.

  17. Assessing the performance of multiplexed tandem PCR for the diagnosis of pathogenic genotypes of Theileria orientalis using pooled blood samples from cattle.

    Science.gov (United States)

    Gebrekidan, Hagos; Gasser, Robin B; Stevenson, Mark A; McGrath, Sean; Jabbar, Abdul

    2017-02-01

    Oriental theileriosis caused by multiple genotypes of Theileria orientalis is an important tick-borne disease of bovines. Here, we assessed the performance of an established multiplexed tandem PCR (MT-PCR) for the diagnosis of the two recognized, pathogenic genotypes (chitose and ikeda) of T. orientalis in cattle using pooled blood samples. We used a total of 265 cattle blood samples, which were divided into two groups according to previous MT-PCR results for individual samples. Samples in group 1 (n = 155) were from a herd with a relatively high prevalence of T. orientalis infection; and those in group 2 (n = 110) were from four herds with a low prevalence. For group 1, 31 and 15 batches of five- and ten-pooled samples (selected at random), respectively, were formed. For group 2, 22 and 11 batches of five- and ten-pooled samples (selected at random), respectively, were formed. DNAs from individual pooled samples in each batch and group were then tested by MT-PCR. For group 1, the apparent prevalences estimated using the 31 batches of five-pooled samples (97%) and 15 batches of ten-pooled samples (100%) were significantly higher compared with individual samples (75%). For group 2, higher apparent prevalences (9% and 36%) were also recorded for the 22 and 11 batches of pooled samples, respectively, compared with individual samples (7%). Overall, the average infection intensity recorded for the genotypes of chitose and ikeda were considerably lower in pooled compared with individual samples. The diagnostic specificities of MT-PCR were estimated at 95% and 94%, respectively, when batches of five- and ten-pooled samples were tested, and 94% for individual samples. The diagnostic sensitivity of this assay was estimated at 98% same for all individual, five- and ten-pooled samples. This study shows that screening batches of five- and ten-pooled blood samples from cattle herds are similar to those obtained for individual samples, and, importantly, that the reduced cost

  18. [Mobbing: ten-year evaluation experience in a University Hospital].

    Science.gov (United States)

    Monaco, Edoardo; Girardi, Paolo; Falaschi, Paolo; Ferracuti, Stefano; Martocchia, Antonio; Battaglia, Valentina; Capitanelli, Ilaria; Catarinozzi, Elena; Piccari, Ines; Rossi, Marina; Prestigiacomo, Claudio

    2017-11-01

    Bullying is a manifestation of occupational stress and can therefore be considered as a real "organizational pathology." Include the activities of the surgery dedicated to Mobbing, Unit of Occupational Medicine Sant'Andrea Hospital, which began operations in June 2001. In over ten years of operation (July 2012), the sample, consisting of 50.7% for men and 49.3% women, is heterogeneous in age. The schooling of the sample is medium-high as more than 82% have higher education level. The business sector is the service sector accounted for most (84%) than in industry (9%) and agriculture (2%). Of the 1545 patients seen, 1320 completed the diagnostic path, while 225 have stopped. 814 users have been certified for compatibility bullying (63% of cases) with a net reduction of the awards from 2007 onwards. Considerations are expressed about the possible intervention strategies: the presence of dedicated experts at the counters of listening and professionals as the trusted advisor, to which workers in distress can call on for advice and guidance on how to defend itself from, in accordance with the implemented for years at the Ministry of Health, the establishment of such figures as the manager rehability that in other European countries, are scheduled for some time in work organization. Copyright© by Aracne Editrice, Roma, Italy.

  19. Early Predictors of Ten-Year Course in First-Episode Psychosis

    DEFF Research Database (Denmark)

    Friis, Svein; Melle, Ingrid; Johannessen, Jan Olav

    2016-01-01

    , five, and ten years (N=186 at ten years). Time in psychosis was defined as time with scores ≥4 on any of the Positive and Negative Syndrome Scale items P1, P3, P5, P6, and G9. Evaluations were retrospective, based on clinical interviews and all available clinical information. During the first two years......, patients were also evaluated by their clinicians at least biweekly. Baseline and early-course predictors of long-term course were identified with linear mixed-model analyses. RESULTS: Four variables provided significant, additive predictions of longer time in psychosis during the ten-year follow...

  20. Monodisperse Picoliter Droplets for Low-Bias and Contamination-Free Reactions in Single-Cell Whole Genome Amplification.

    Directory of Open Access Journals (Sweden)

    Yohei Nishikawa

    Full Text Available Whole genome amplification (WGA is essential for obtaining genome sequences from single bacterial cells because the quantity of template DNA contained in a single cell is very low. Multiple displacement amplification (MDA, using Phi29 DNA polymerase and random primers, is the most widely used method for single-cell WGA. However, single-cell MDA usually results in uneven genome coverage because of amplification bias, background amplification of contaminating DNA, and formation of chimeras by linking of non-contiguous chromosomal regions. Here, we present a novel MDA method, termed droplet MDA, that minimizes amplification bias and amplification of contaminants by using picoliter-sized droplets for compartmentalized WGA reactions. Extracted DNA fragments from a lysed cell in MDA mixture are divided into 105 droplets (67 pL within minutes via flow through simple microfluidic channels. Compartmentalized genome fragments can be individually amplified in these droplets without the risk of encounter with reagent-borne or environmental contaminants. Following quality assessment of WGA products from single Escherichia coli cells, we showed that droplet MDA minimized unexpected amplification and improved the percentage of genome recovery from 59% to 89%. Our results demonstrate that microfluidic-generated droplets show potential as an efficient tool for effective amplification of low-input DNA for single-cell genomics and greatly reduce the cost and labor investment required for determination of nearly complete genome sequences of uncultured bacteria from environmental samples.

  1. Optimisation methodology in the chiral and achiral separation in electrokinetic chromatography in the case of a multicomponent sample of dansyl amino acids.

    Science.gov (United States)

    Giuffrida, Alessandro; Messina, Marianna; Contino, Annalinda; Cucinotta, Vincenzo

    2013-11-01

    Two different chiral selectors synthesised in our laboratory were used to test the possibility of separation for a sample consisting of ten different enantiomeric pairs of dansyl-derivatives of α-amino acids in electrokinetic chromatography. It was possible to observe all the peaks, though only partly resolved, due to the twenty analytes through an accurate strategy of choice of the experimental conditions. As a part of this strategy, a procedure of identification of the single peaks in the electropherograms called LACI (lastly added component identification) has been developed. Copyright © 2013 Elsevier B.V. All rights reserved.

  2. Ten years of nuclear power

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1964-08-15

    Ten years have elapsed since the world's first nuclear power station began to supply electricity in Russia, and this in turn marked the end of a twelve year stage following the first controlled nuclear chain reaction at Chicago. These periods mark major stages in the development of atomic energy from the realm of abstract ideas to that of everyday industrial application. They followed a period of fundamental research and laboratory work, culminating in Enrico Fermi's demonstration of a system whereby the forces of the atom could be brought under control. Then it was necessary to find ways and means of using the chain reaction for practical purposes and on an industrial scale. And after this had been shown in 1954 to be technically possible, it had still to be developed into an economic process. The nuclear power station has proved itself from the technical and engineering standpoint. The third phase of development has been to bring it to the stage of being economically competitive with alternative sources of energy, and it would appear that we are now reaching that goal - though more slowly than had been envisaged ten years ago

  3. Dendro-analysis: the study of trace elements in tree rings

    International Nuclear Information System (INIS)

    Gilboy, W.B.; Tout, R.E.; Spyrou, N.M.

    1976-01-01

    In attempts to study environmental contamination over long time scales into the past, the levels of trace and minor elements in individual tree rings have been measured using instrumental neutron activation analysis. Most measurements so far have been done on elm tree samples which are widely available due to a current epidemic of Dutch Elm disease in southern England. Samples taken from every growth ring were individually activated for ten minutes in a thermal neutron flux of 1.5 x 10 12 n cm -2 sec -1 in the 100 kW London University research reactor. The activated samples were counted for ten minutes on a 42 cm 3 Ge(Li) gamma ray detector. These procedures enabled the following radioisotopes to be monitored for a large number of samples: 19 0, 24 Na, 27 Mg, 28 Al, 38 Cl, 42 K, 49 Ca, 56 Mn, 66 Cu, 80 Br, 87 /sup m/Sr, 41 Ar, 128 I, 139 Ba. Some of the above isotopes show striking systematic variations both from ring to ring in a radial direction, and also around individual rings. Results are described in detail for samples taken from trees grown in various locations and assesses the potential of this technique for studying past environmental conditions

  4. Sample-related peripheral equipment at IPNS

    International Nuclear Information System (INIS)

    Bohringer, D.E.; Crawford, R.K.

    1985-01-01

    This paper describes samples environment equipment provided by IPNS to visiting users and staff scientists. Of the twelve horizontal neutron beam stations, (ten now operational, two under construction) all use one or more form of such support equipment. An in-house support group devotes a significant fraction of its time to development, calibration, and maintenance of this equipment

  5. Automated processing of the single-lead electrocardiogram for the detection of obstructive sleep apnoea.

    Science.gov (United States)

    de Chazal, Philip; Heneghan, Conor; Sheridan, Elaine; Reilly, Richard; Nolan, Philip; O'Malley, Mark

    2003-06-01

    A method for the automatic processing of the electrocardiogram (ECG) for the detection of obstructive apnoea is presented. The method screens nighttime single-lead ECG recordings for the presence of major sleep apnoea and provides a minute-by-minute analysis of disordered breathing. A large independently validated database of 70 ECG recordings acquired from normal subjects and subjects with obstructive and mixed sleep apnoea, each of approximately eight hours in duration, was used throughout the study. Thirty-five of these recordings were used for training and 35 retained for independent testing. A wide variety of features based on heartbeat intervals and an ECG-derived respiratory signal were considered. Classifiers based on linear and quadratic discriminants were compared. Feature selection and regularization of classifier parameters were used to optimize classifier performance. Results show that the normal recordings could be separated from the apnoea recordings with a 100% success rate and a minute-by-minute classification accuracy of over 90% is achievable.

  6. Von Blüten, Göttern und Gelehrten

    OpenAIRE

    Zotter, Astrid

    2013-01-01

    Der Sanskrittext Puṣpacintāmaṇi (PuCi) behandelt Blüten als Darbringungen (upacāra) im wichtigsten hinduistischen Verehrungsritual, der pūjā. In ca. 400 Strophen werden über 200 Namen von Blüten genannt und für verschiedene Gottheiten und pūjās als geeignete oder ungeeignete Gaben vorgeschrieben. Der Text ist eine Kompilation (Nibandha), in der die Inhalte aus 47 namentlich genannten Quellentexten referiert werden. Ziel der Dissertation ist es nicht nur, diesen Text, der 1966 zum ersten Ma...

  7. Analysis of single oil-bearing fluid inclusions in mid-Proterozoic sandstones (Roper Group, Australia)

    Science.gov (United States)

    Siljeström, Sandra; Volk, Herbert; George, Simon C.; Lausmaa, Jukka; Sjövall, Peter; Dutkiewicz, Adriana; Hode, Tomas

    2013-12-01

    Hydrocarbons and organic biomarkers extracted from black shales and other carbonaceous sedimentary rocks are valuable sources of information on the biodiversity and environment of early Earth. However, many Precambrian hydrocarbons including biomarkers are suspected of being younger contamination. An alternative approach is to study biomarkers trapped in oil-bearing fluid inclusions by bulk crushing samples and subsequently analysing the extracted hydrocarbons with gas chromatography-mass spectrometry. However, this method does not constrain the hydrocarbons to one particular oil inclusion, which means that if several different generations of oil inclusions are present in the sample, a mix of the content from these oil inclusions will be analysed. In addition, samples with few and/or small inclusions are often below the detection limit. Recently, we showed that it is possible to detect organic biomarkers in single oil-bearing fluid inclusions using time-of-flight secondary ion mass spectrometry (ToF-SIMS). In the present study, single fluid inclusion analysis has been performed on Proterozoic samples for the first time. Four individual oil-bearing fluid inclusions, found in 1430 Ma sandstone from the Roper Superbasin in Northern Australia, were analysed with ToF-SIMS. The ToF-SIMS spectra of the oil in the different inclusions are very similar to each other and are consistent with the presence of n-alkanes/branched alkanes, monocyclic alkanes, bicyclic alkanes, aromatic hydrocarbons, and tetracyclic and pentacyclic hydrocarbons. These results are in agreement with those obtained from bulk crushing of inclusions trapped in the same samples. The capability to analyse the hydrocarbon and biomarker composition of single oil-bearing fluid inclusions is a major breakthrough, as it opens up a way of obtaining molecular compositional data on ancient oils without the ambiguity of the origin of these hydrocarbons. Additionally, this finding suggests that it will be possible

  8. Impact of single anaerobic exercise on delayed activation of endothelial xanthine oxidase in men and women.

    Science.gov (United States)

    Wiecek, Magdalena; Maciejczyk, Marcin; Szymura, Jadwiga; Kantorowicz, Malgorzata; Szygula, Zbigniew

    2017-11-01

    The aim of the study was to evaluate the activity of xanthine oxidase (XO) in the blood of men and women during the first hour following a single anaerobic exercise (AN-EX), and after 24 hours of recovery, and to determine whether the changes in XO activity in the blood after AN-EX are dependent on anaerobic performance. Ten men and ten women performed a single AN-EX. Blood was collected before and five times after completion of the AN-EX. The activity of XO was determined. In both groups, a significant (P women (P work performed during the AN-EX and the power decrease. In the first hour after the single AN-EX, XO activity in the blood of women and men did not change, but after 24 hours of recovery, it was significantly higher compared to baseline levels in both sexes. Single AN-EX causes a smaller increase in XO activity in people with higher anaerobic performance.

  9. What Do Lead and Copper Sampling Protocols Mean, and Which Is Right for You?

    Science.gov (United States)

    this presentation will provide a short review of the explicit and implicit concepts behind most of the currently-used regulatory and diagnostic sampling schemes for lead, such as: random daytime sampling; automated proportional sampler; 30 minute first draw stagnation; Sequential...

  10. [Clinical retrospective control study of single-port laparoendoscopic and multi-port laparoscopic ovarian cystectomy].

    Science.gov (United States)

    Liu, X; Wen, M K; Liu, H Y; Sun, D W; Lang, J H; Fan, Q B; Shi, H H

    2017-10-25

    Objective: To investigate clinical outcomes of laparoendoscopic single-site ovarian cystectomy compared with traditional multi-port laparoscopic ovarian cystectomy. Methods: Data of 81 patients with ovarian cystectomy from January 2016 to May 2017, the single-site group ( n= 40) and the multi-port group ( n= 41) in Peking Union Medical College Hospital were retrospectively collected. The outcomes of single-site and multi-port groups were analyzed and compared, including: postoperative fever, operation time, blood loss, hemoglobin change, surgical complications, postoperative pain score, postoperative analgesic requirements, body image scale and cosmetic score, length of hospital stay, postoperative total cost. Results: No complication was found in two groups. No difference was found in postoperative fever, blood loss, hemoglobin change, postoperative pain score, length of hospital stay, and total cost between the two groups (all P> 0.05). Operation time was (50±20) minutes in single-site group, and (40±15) minutes in multi-port group; postoperative analgesic requirements was 28%(11/40) in single-site group, and 7%(4/41) in multi-port group; cosmetic score was 22.6±2.6 in single-site group, and 17.3±2.6 in multi-port group; body image scale was 5.7±1.2 in single-site group, and 6.2±1.2 in multi-port group; these four clinical parameters were statistical differences (all P< 0.05). Conculsion: Laparoendoscopic single-site ovarian cystectomy is feasible and safe, although it could't relieve the postoperative pian, it do offer a higher cosmetic satisfaction.

  11. Five-minute grid shapefile with marine bird density data off central California, CDAS data (1980-2001)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — A shapefile of five minute grids that contains marine bird density data at-sea from the CDAS Central CA data set (1980-2001). It is a shapefile representing 5 minute...

  12. Assessing the effects of transcutaneous electrical nerve stimulation (TENS) in post-thoracotomy analgesia.

    Science.gov (United States)

    Ferreira, Fabiana Cristina; Issy, Adriana Machado; Sakata, Rioko Kimiko

    2011-01-01

    Transcutaneous electrical nerve stimulation (TENS) is commonly used to treat musculoskeletal pain, but it may also be indicated for postoperative analgesia. The objective of this study was to evaluate the analgesic effects of TENS on post-thoracotomy. Thirty patients between 18 and 60 years of age undergoing thoracotomy for lung cancer resection on the second postoperative day were included in this study. Patients were divided into two groups (G1 and G2). G1 patients were treated with TENS; and in G2 (without TENS) electrodes were placed but the equipment was not turned on. TENS was maintained for one hour. The visual analogue scale was used to evaluate the analgesic effects on three moments: before TENS (M0), immediately after TENS (M1), and one hour later (M2), with the patient at rest, elevation of the upper limbs, change in decubitus, and coughing. The intensity of pain at rest was higher in G2 immediately after TENS, but not one hour after the procedure. There was no difference between both groups with elevation of the upper limbs, decubitus change, and coughing. With the use of TENS for one hour on the second post-thoracotomy day in patients who received fentanyl (50 μg) associated with bupivacaine (5 mL), a reduction in pain intensity was observed at rest immediately after TENS; with elevation of the upper limbs, change in decubitus, and coughing, a reduction in pain severity was not observed. Copyright © 2011 Elsevier Editora Ltda. All rights reserved.

  13. Effectiveness of a 40-minute Ophthalmologic Examination Teaching Session on Medical Student Learning

    Directory of Open Access Journals (Sweden)

    Wirachin Hoonpongsimanont

    2015-10-01

    Full Text Available Introduction: Emergency physicians are among the few specialists besides ophthalmologists who commonly perform ophthalmologic examinations using the slit lamp and other instruments. However, most medical schools in the United States do not require an ophthalmology rotation upon completion. Teaching procedural skills to medical students can be challenging due to limited resources and instructor availability. Our study assesses the effectiveness of a 40-minute hands-on teaching session on ophthalmologic examination for medical students using only two instructors and low-cost equipment. Methods: We performed an interventional study using a convenience sample of subjects. Pre- and post-workshop questionnaires on students’ confidence in performing ophthalmologic examination were administered. We used a paired t-test and Wilcoxon rank test to analyze the data. Results: Of the 30 participants in the study, the mean age was 25 and the majority were first-year medical students. The students’ confidence in performing every portion of the ophthalmologic exam increased significantly after the teaching session. We found that the average confidence level before the teaching session were below 2 on a 1-5 Likert scale (1 being the least confident. Confidence levels in using the slit lamp had the highest improvement among the skills taught (2.17 95% CI [1.84-2.49]. Students reported the least improvement in their confidence in assessing extraocular movements (0.73, 95% CI [0.30-1.71] and examining pupillary function (0.73, 95% CI [0.42-1.04]. We observed the biggest difference in median confidence level in the use of the tonometer (4 with a p-value of <0.05. Conclusion: A 40-minute structured hands-on training session can significantly improve students’ confidence levels in ophthalmologic skills.

  14. Landslide Susceptibility Assessment Using Frequency Ratio Technique with Iterative Random Sampling

    Directory of Open Access Journals (Sweden)

    Hyun-Joo Oh

    2017-01-01

    Full Text Available This paper assesses the performance of the landslide susceptibility analysis using frequency ratio (FR with an iterative random sampling. A pair of before-and-after digital aerial photographs with 50 cm spatial resolution was used to detect landslide occurrences in Yongin area, Korea. Iterative random sampling was run ten times in total and each time it was applied to the training and validation datasets. Thirteen landslide causative factors were derived from the topographic, soil, forest, and geological maps. The FR scores were calculated from the causative factors and training occurrences repeatedly ten times. The ten landslide susceptibility maps were obtained from the integration of causative factors that assigned FR scores. The landslide susceptibility maps were validated by using each validation dataset. The FR method achieved susceptibility accuracies from 89.48% to 93.21%. And the landslide susceptibility accuracy of the FR method is higher than 89%. Moreover, the ten times iterative FR modeling may contribute to a better understanding of a regularized relationship between the causative factors and landslide susceptibility. This makes it possible to incorporate knowledge-driven considerations of the causative factors into the landslide susceptibility analysis and also be extensively used to other areas.

  15. Microstructural, Raman and XPS properties of single-crystalline Bi3.15Nd0.85Ti3O12 nanorods

    International Nuclear Information System (INIS)

    Hu Zhenglong; Gu Haoshuang; Hu Yongming; Zou Yanan; Zhou Di

    2009-01-01

    Bi 3.15 Nd 0.85 Ti 3 O 12 (BNT) nanorods were successfully synthesized first time by hydrothermal method. The nanorods are uniform along their length, and are composed of single-crystalline BNT with orthorhombic structure. The diameters of BNT nanorods are about 30-120 nm and growth along the [1 0 4] direction, which are promising candidate for nanoscale ferroelectric sensors. Ten Raman active modes were observed for orthorhombic phase BNT nanorods, which are overdamped and highly shifted compare to that of Bi 4 Ti 3 O 12 (BIT) powders. The chemical composition of the samples and the valence states of elements were determined by X-ray photoelectron spectroscopy

  16. Autonomous calibration of single spin qubit operations

    Science.gov (United States)

    Frank, Florian; Unden, Thomas; Zoller, Jonathan; Said, Ressa S.; Calarco, Tommaso; Montangero, Simone; Naydenov, Boris; Jelezko, Fedor

    2017-12-01

    Fully autonomous precise control of qubits is crucial for quantum information processing, quantum communication, and quantum sensing applications. It requires minimal human intervention on the ability to model, to predict, and to anticipate the quantum dynamics, as well as to precisely control and calibrate single qubit operations. Here, we demonstrate single qubit autonomous calibrations via closed-loop optimisations of electron spin quantum operations in diamond. The operations are examined by quantum state and process tomographic measurements at room temperature, and their performances against systematic errors are iteratively rectified by an optimal pulse engineering algorithm. We achieve an autonomous calibrated fidelity up to 1.00 on a time scale of minutes for a spin population inversion and up to 0.98 on a time scale of hours for a single qubit π/2 -rotation within the experimental error of 2%. These results manifest a full potential for versatile quantum technologies.

  17. [Smoking among psychology students over a ten-year period (1996-2006)].

    Science.gov (United States)

    Míguez Varela, María del Carmen; Becoña Iglesias, Elisardo

    2009-11-01

    The purpose of this study was to analyze the evolution of smoking among Psychology students at the University of Santiago de Compostela (Spain) over a ten-year period (1986-2006). We also assessed the extent of knowledge of the Spanish health legislation on tobacco (Ley 28/2005) and its effect on smoking. We administered a questionnaire to representative samples of students from the 1st year of their Psychology course to the 5th year, on four occasions. In the academic year 1996-1997 (N = 835), 34% of the sample claimed to be daily smokers; in 1999-2000 (N = 842), the figure was 35.2%; in 2003-2004 (N = 835) it was 31.9%; and in 2006-2007 (N = 688), it was 22.8%. Moreover, in the last assessment, 97.1% of the sample reported being aware of the legislation (Ley 28/2005) and 41.9% of the smokers claimed that it had some degree of influence on their smoking. It can be stated that, although overall current prevalence of smoking is similar to that of 10 years ago, a significant change is observed in the profile of smokers. This change is expressed in lower levels of nicotine dependence and a decrease in the percentage of daily smokers, together with an increase in occasional smokers.

  18. Kaluza-Klein supergravity in ten dimensions

    International Nuclear Information System (INIS)

    Huq, M.; Namazie, M.A.

    1983-11-01

    We construct a massive version of N=2 supergravity in ten dimensions by compactification of the eleven dimensional, N=1 theory. This theory describes the usual N=2 massless super-multiplet, in addition to which there is an infinite tower of massive, charged N=2 supermultiplets. (author)

  19. Ten themes of viscous liquid dynamics

    DEFF Research Database (Denmark)

    Dyre, J. C.

    2007-01-01

    Ten ‘themes' of viscous liquid physics are discussed with a focus on how they point to a general description of equilibrium viscous liquid dynamics (i.e., fluctuations) at a given temperature. This description is based on standard time-dependent Ginzburg-Landau equations for the density fields...

  20. The Viking X ray fluorescence experiment - Sampling strategies and laboratory simulations. [Mars soil sampling

    Science.gov (United States)

    Baird, A. K.; Castro, A. J.; Clark, B. C.; Toulmin, P., III; Rose, H., Jr.; Keil, K.; Gooding, J. L.

    1977-01-01

    Ten samples of Mars regolith material (six on Viking Lander 1 and four on Viking Lander 2) have been delivered to the X ray fluorescence spectrometers as of March 31, 1977. An additional six samples at least are planned for acquisition in the remaining Extended Mission (to January 1979) for each lander. All samples acquired are Martian fines from the near surface (less than 6-cm depth) of the landing sites except the latest on Viking Lander 1, which is fine material from the bottom of a trench dug to a depth of 25 cm. Several attempts on each lander to acquire fresh rock material (in pebble sizes) for analysis have yielded only cemented surface crustal material (duricrust). Laboratory simulation and experimentation are required both for mission planning of sampling and for interpretation of data returned from Mars. This paper is concerned with the rationale for sample site selections, surface sampler operations, and the supportive laboratory studies needed to interpret X ray results from Mars.