  1. Image guided placement of temporary anchorage devices for tooth movement

    Energy Technology Data Exchange (ETDEWEB)

    Bahl-Palomo, L.; Bissada, N. [Case Western Reserve Univ. School of Dental Medicine, Dept. of Periodontics, Cleveland, OH (United States); Palomo, J.M.; Hans, M.G. [Case Western Reserve Univ. School of Dental Medicine, Dept. of Orthodontics, Cleveland, OH (United States)

    2007-06-15

    The aim of this project is to develop an image guided protocol for placement of a temporary anchorage device without surgically reflecting a mucoperiosteal flap. Eighteen orthodontic cases were selected for skeletal anchorage from the department of orthodontics at Case University. CBCT images of the subjects were taken using the Hitachi CB MercuRay system set at 15 mA, 120 kVp. CBCT images evaluated the ideal location for TAD placement in three dimensions. Horizontal and vertical linear measurements were taken from fixed dental landmarks to clearly define the location for placement. Transverse slices were used to evaluate the thickness of the buccal plate. Using the transverse view, the angle of insertion was determined such that the maximum buccal plate surface area would contact the screw. TADs were placed in the optimum location, with the most appropriate angle of insertion using a closed approach and with minimal local anesthesia and without flap elevation. Results: All TADs were placed without anatomic encroachment and enabled fixed orthodontic anchorage. (orig.)

  2. Image guided placement of temporary anchorage devices for tooth movement

    International Nuclear Information System (INIS)

    Bahl-Palomo, L.; Bissada, N.; Palomo, J.M.; Hans, M.G.

    2007-01-01

    The aim of this project is to develop an image guided protocol for placement of a temporary anchorage device without surgically reflecting a mucoperiosteal flap. Eighteen orthodontic cases were selected for skeletal anchorage from the department of orthodontics at Case University. CBCT images of the subjects were taken using the Hitachi CB MercuRay system set at 15 mA, 120 kVp. CBCT images evaluated the ideal location for TAD placement in three dimensions. Horizontal and vertical linear measurements were taken from fixed dental landmarks to clearly define the location for placement. Transverse slices were used to evaluate the thickness of the buccal plate. Using the transverse view, the angle of insertion was determined such that the maximum buccal plate surface area would contact the screw. TADs were placed in the optimum location, with the most appropriate angle of insertion using a closed approach and with minimal local anesthesia and without flap elevation. Results: All TADs were placed without anatomic encroachment and enabled fixed orthodontic anchorage. (orig.)

  3. Digital lingual orthodontics and temporary anchorage devices for efficient biomechanics

    Directory of Open Access Journals (Sweden)

    Pravin Shetty

    2016-01-01

    Full Text Available Adult patients seeking orthodontic treatment at all times present with an esthetic demand even during treatment. The lingual orthodontics, apart from its esthetic values, also presents several other advantages. Currently, it has become a complete system in itself, starting from an accurate diagnosis, treatment protocol, and laboratory procedure to placement of the appliance in the patient′s mouth. With the advent of computer-aided design/computer-aided manufacturing system, the lingual orthodontics is more evolved and made ease operators in respect to more efficient mechanics and reduced archwire adjustments. The present article presents two cases to show the efficiency of lingual orthodontics with temporary anchorage devices and anterior retraction hook.

  4. Management of post midface distraction occlusal discrepancy using temporary anchorage devices in a cleft patient

    Directory of Open Access Journals (Sweden)

    N K Koteswara Prasad

    2015-01-01

    Full Text Available Open bite deformity following a successful midface advancement by distraction osteogenesis is a common complication. Temporary anchorage devices can be deployed during the distraction and post-distraction settling phases for restoring the occlusion even in severe cases. The following report describes the management of severe anterior open bite following maxillary distraction.

  5. Management of post midface distraction occlusal discrepancy using temporary anchorage devices in a cleft patient

    Science.gov (United States)

    Koteswara Prasad, N. K.; Hussain, Syed Altaf; Chitharanjan, Arun B.; Murthy, Jyotsna

    2015-01-01

    Open bite deformity following a successful midface advancement by distraction osteogenesis is a common complication. Temporary anchorage devices can be deployed during the distraction and post-distraction settling phases for restoring the occlusion even in severe cases. The following report describes the management of severe anterior open bite following maxillary distraction. PMID:25991895

  6. Success rates and factors associated with failure of temporary anchorage devices: A prospective clinical trial.

    Science.gov (United States)

    Aly, Shehab A; Alyan, Doha; Fayed, Mona S; Alhammadi, Maged S; Mostafa, Yehya A

    2018-03-06

    The objective of the present study was to investigate success rates and associated factors affecting temporary anchorage device (TAD) failure in different biomechanical applications. A total of 180 TADs were used as a part of 82 patients' treatment plan (24 males and 58 females); their mean age was 21.41 years. Three types of TADs were used: 50 (3M ESPE, Neuss, Germany), 56 (Bone screw; Jeil Medical, Seoul, Korea), and 74 (Morelli, Sorocaba, Brazil). Eight maxillary and four mandibular sites were selected for insertion. Three different lengths (6, 8, and 10 mm) and three different diameters (1.5, 1.6, and 1.8 mm) were used. The force levels were set at 50, 100, 150, 200, and 250 g. Patient-, implant-, and operator-dependent factors were evaluated throughout the 266 days of function. Qualitative variables were described by proportions and percentages and analyzed using χ 2 test. The overall success rate was 82.2%. The higher age group showed a significantly higher success rate. Oral hygiene showed a statistically-significant (P ˂ .05) difference between both success and failure groups. All other patient-related factors showed no significant differences. Regarding force levels used, the highest success rate was in 250 g and the lowest was in 100 g. There were no significant differences between both groups regarding other implant- and operator-related factors. Temporary anchorage devices have a good success rate and are beneficial to be integrated in orthodontic treatment planning. Patient age, oral hygiene, and force level are the most significant factors affecting TAD success. © 2018 John Wiley & Sons Australia, Ltd.

  7. Comparison of anchorage reinforcement with temporary anchorage devices or a Herbst appliance during lingual orthodontic protraction of mandibular molars without maxillary counterbalance extraction.

    Science.gov (United States)

    Metzner, Rebecca; Schwestka-Polly, Rainer; Helms, Hans-Joachim; Wiechmann, Dirk

    2015-06-20

    Orthodontic protraction of mandibular molars without maxillary counterbalance extraction in cases of aplasia or extraction requires stable anchorage. Reinforcement may be achieved by using either temporary anchorage devices (TAD) or a fixed, functional appliance. The objective was to compare the clinical effectiveness of both methods by testing the null-hypothesis of no significant difference in velocity of space closure (in mm/month) between them. In addition, we set out to describe the quality of posterior space management and treatment-related factors, such as loss of anchorage (assessed in terms of proportions of gap closure by posterior protraction or anterior retraction), frequencies of incomplete space closure, and potential improvement in the sagittal canine relationship. Twenty-seven subjects (15 male/12 female) with a total of 36 sites treated with a lingual multi-bracket appliance were available for retrospective evaluation of the effects of anchorage reinforcement achieved with either a Herbst appliance (n(subjects) = 15; 7 both-sided/8 single-sided Herbst appliances; n(sites) = 22) or TADs (n(subjects )= 12; 2 both-sided; 10 single-sided; n(sites) = 14). Descriptive analysis was based on measurements using intra-oral photographs which were individually scaled to corresponding plaster casts and taken on insertion of anchorage mechanics (T1), following removal of anchorage mechanics (T2), and at the end of multi-bracket treatment (T3). The null-hypothesis was rejected: The rate of mean molar protraction was significantly faster in the Herbst-reinforced group (0.51 mm/month) than in the TAD group (0.35). While complete space closure by sheer protraction of posterior teeth was achieved in all Herbst-treated cases, space closure in the TAD group was achieved in 76.9% of subjects by sheer protraction of molars, and it was incomplete in 50% of cases (mean gap residues: 1 mm). Whilst there was a deterioration in the canine relationship towards

  8. British Orthodontic Society national audit of temporary anchorage devices (TADs): report of the first thousand TADs placed.

    Science.gov (United States)

    Bearn, David R; Alharbi, Fahad

    2015-09-01

    To provide data from the British Orthodontic Society (BOS) national clinical audit on temporary anchorage device (TAD) use following the recommendations of the National Institute for Health and Clinical Excellence (NIHCE) Design and setting: The Audit commenced on 1 January 2008 and is still ongoing. This article reports the data for TADs placed from 1 January 2008 to 1 November 2013. Audit data was collected from participants using a system of both on-line data entry and hard copy forms. The criteria and standards for the audit were set following the NIHCE report in conjunction with the Development and Standards Committee of the BOS. Virtually all participants used the on-line data entry available on the BOS website. The data submitted was checked and entered manually into an Excel spreadsheet, and transferred to SPSS for analysis. Written information and documented discussion of risks were provided in over 90% of TADs placed, but 17.4% were placed without a specific signed consent form. Temporary anchorage device failure rate was 24.2% overall. Among failed TADs, 93.1% were lost or removed due to excess mobility. Infection or inflammation resulting in loss or removal was reported in 6% of TADs. The only audit standard that was met was failures due to infection of inflammation. The rest of the audit standards were not met. Recommendations are made to address these issues.

  9. Use of reconstructed CT images for evaluation of the position of screw-type temporary anchorage devices implanted in the maxillary molar region

    International Nuclear Information System (INIS)

    Hashimoto, Kazuya

    2007-01-01

    Temporary anchorage devices (TAD) have recently been employed for orthodontic treatment. I attempted to find the safest position for placing the screw-type TAD in the maxillary molar region. Using reconstructed CT images, I investigated the buccolingual and mesiodistal lengths of the interalveolar septums between the maxillary first premolar, second premolar, first molar, and the second molar. For the first and second molars, I measured the distance from the alveolar crest to the maxillary sinus. The results indicated that the safest position for placing a screw-type TAD was the interalveolar septum between the maxillary first molar and the second premolar at about a depth of 4-6 mm from the alveolar crest on the buccal side, and at about a depth of 2-6 mm from the alveolar crest on the palatal side. (author)

  10. En-masse retraction with a preformed nickel-titanium and stainless steel archwire assembly and temporary skeletal anchorage devices without posterior bonding

    Science.gov (United States)

    Jee, Jeong-Hyun; Ahn, Hyo-Won; Seo, Kyung-Won; Kook, Yoon-Ah; Chung, Kyu-Rhim; Nelson, Gerald

    2014-01-01

    Objective To evaluate the therapeutic effects of a preformed assembly of nickel-titanium (NiTi) and stainless steel (SS) archwires (preformed C-wire) combined with temporary skeletal anchorage devices (TSADs) as the sole source of anchorage and to compare these effects with those of a SS version of C-wire (conventional C-wire) for en-masse retraction. Methods Thirty-one adult female patients with skeletal Class I or II dentoalveolar protrusion, mild-to-moderate anterior crowding (3.0-6.0 mm), and stable Class I posterior occlusion were divided into conventional (n = 15) and preformed (n = 16) C-wire groups. All subjects underwent first premolar extractions and en-masse retraction with pre-adjusted edgewise anterior brackets, the assigned C-wire, and maxillary C-tubes or C-implants; bonded mesh-tube appliances were used in the mandibular dentition. Differences in pretreatment and post-retraction measurements of skeletal, dental, and soft-tissue cephalometric variables were statistically analyzed. Results Both groups showed full retraction of the maxillary anterior teeth by controlled tipping and space closure without altered posterior occlusion. However, the preformed C-wire group had a shorter retraction period (by 3.2 months). Furthermore, the maxillary molars in this group showed no significant mesialization, mesial tipping, or extrusion; some mesialization and mesial tipping occurred in the conventional C-wire group. Conclusions Preformed C-wires combined with maxillary TSADs enable simultaneous leveling and space closure from the beginning of the treatment without maxillary posterior bonding. This allows for faster treatment of dentoalveolar protrusion without unwanted side effects, when compared with conventional C-wire, evidencing its clinical expediency. PMID:25309863

  11. En-masse retraction with a preformed nickel-titanium and stainless steel archwire assembly and temporary skeletal anchorage devices without posterior bonding.

    Science.gov (United States)

    Jee, Jeong-Hyun; Ahn, Hyo-Won; Seo, Kyung-Won; Kim, Seong-Hun; Kook, Yoon-Ah; Chung, Kyu-Rhim; Nelson, Gerald

    2014-09-01

    To evaluate the therapeutic effects of a preformed assembly of nickel-titanium (NiTi) and stainless steel (SS) archwires (preformed C-wire) combined with temporary skeletal anchorage devices (TSADs) as the sole source of anchorage and to compare these effects with those of a SS version of C-wire (conventional C-wire) for en-masse retraction. Thirty-one adult female patients with skeletal Class I or II dentoalveolar protrusion, mild-to-moderate anterior crowding (3.0-6.0 mm), and stable Class I posterior occlusion were divided into conventional (n = 15) and preformed (n = 16) C-wire groups. All subjects underwent first premolar extractions and en-masse retraction with pre-adjusted edgewise anterior brackets, the assigned C-wire, and maxillary C-tubes or C-implants; bonded mesh-tube appliances were used in the mandibular dentition. Differences in pretreatment and post-retraction measurements of skeletal, dental, and soft-tissue cephalometric variables were statistically analyzed. Both groups showed full retraction of the maxillary anterior teeth by controlled tipping and space closure without altered posterior occlusion. However, the preformed C-wire group had a shorter retraction period (by 3.2 months). Furthermore, the maxillary molars in this group showed no significant mesialization, mesial tipping, or extrusion; some mesialization and mesial tipping occurred in the conventional C-wire group. Preformed C-wires combined with maxillary TSADs enable simultaneous leveling and space closure from the beginning of the treatment without maxillary posterior bonding. This allows for faster treatment of dentoalveolar protrusion without unwanted side effects, when compared with conventional C-wire, evidencing its clinical expediency.

  12. Comparison of in-vivo failure of single-thread and dual-thread temporary anchorage devices over 18 months: A split-mouth randomized controlled trial.

    Science.gov (United States)

    Durrani, Owais Khalid; Shaheed, Sohrab; Khan, Arsalan; Bashir, Ulfat

    2017-10-01

    The purpose of this study was to compare the in-vivo failure rates of single-thread and dual-thread temporary anchorage device (TAD) designs over 18 months. Thirty patients with skeletal Class II Division 1 malocclusion requiring anchorage from TADs for retraction of maxillary incisors into the extracted premolar space were recruited in this parallel group, split-mouth, randomized controlled trial. A block randomization sequence was generated with Random Allocation Software (version 2.0; Isfahan, Iran) with the allocations concealed in sequentially numbered, opaque, sealed envelopes. A total of 60 TADs (diameter, 2 mm; length, 10 mm) were placed in the maxillary arches of these patients with random allocation of the 2 types to the left and the right sides in a 1:1 ratio. All TADs were placed between the roots of the second premolar and the first molar and were immediately loaded. Patients were followed for a minimum of 12 months and a maximum of 18 months for the failure of the TADs. Data were analyzed blindly on an intention-to-treat basis. Four TADs (13.3%) failed in the single-thread group, and 6 TADs (20%) failed in the dual-thread group. The McNemar test showed an insignificant difference (P = 0.72) between the 2 groups. An odds ratio of 1.6 (95% confidence interval, 0.39-6.97) showed no significant associations among the variables. Most TADs failed in the first month after insertion (50%). The failure rate of dual-thread TADs compared with single-thread TADs is statistically insignificant when placed in the maxilla for retraction of the anterior segment. Registration: The trial was not registered before commencement. The protocol was not published before the trial. Copyright © 2016 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  13. Modified Miniplates for Temporary Skeletal Anchorage in Orthodontics: Placement and Removal Surgeries

    Science.gov (United States)

    Cornelis, Marie A.; Scheffler, Nicole R.; Mahy, Pierre; Siciliano, Sergio; De Clerck, Hugo J.; Tulloch, J.F. Camilla

    2009-01-01

    Purpose Skeletal anchorage systems are increasingly used in orthodontics. This article describes the techniques of placement and removal of modified surgical miniplates used for temporary orthodontic anchorage and reports surgeons’ perceptions of their use. Patients and Methods We enrolled 97 consecutive orthodontic patients having miniplates placed as an adjunct to treatment. A total of 200 miniplates were placed by 9 oral surgeons. Patients and surgeons completed questionnaires after placement and removal surgeries. Results Fifteen miniplates needed to be removed prematurely. Antibiotics and anti-inflammatories were generally prescribed after placement but not after removal surgery. Most surgeries were performed with the patient under local anesthesia. Placement surgery lasted on average between 15 and 30 minutes per plate and was considered by the surgeons to be very easy to moderately easy. The surgery to remove the miniplates was considered easier and took less time. The patients’ chief complaint was swelling, lasting on average 5.3 ± 2.8 days after placement and 4.5 ± 2.6 days after removal. Conclusions Although miniplate placement/removal surgery requires the elevation of a flap, this was considered an easy and relatively short surgical procedure that can typically be performed with the patient under local anesthesia without complications, and it may be considered a safe and effective adjunct for orthodontic treatment. PMID:18571028

  14. Factors affecting the clinical success of orthodontic anchorage: Experience with 266 temporary anchorage devices

    Directory of Open Access Journals (Sweden)

    Tai-Ting Lai

    2014-03-01

    Conclusion: In order to improve the success rates, local inflammation should be monitored and controlled, force application should be 4 weeks after insertion, and the location for placement of TADs should be good quality bone with keratinized mucosa.

  15. 29 CFR 1926.154 - Temporary heating devices.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 8 2010-07-01 2010-07-01 false Temporary heating devices. 1926.154 Section 1926.154 Labor... Temporary heating devices. (a) Ventilation. (1) Fresh air shall be supplied in sufficient quantities to... heating devices shall be installed to provide clearance to combustible material not less than the amount...

  16. Disimpaction of maxillary canines using temporary bone anchorage and cantilever springs.

    Science.gov (United States)

    Thebault, Benoit; Dutertre, Eric

    2015-03-01

    Impacted canines, particularly in the maxilla, are frequently encountered in orthodontic practice. Unfortunately, depending on their position, correction can often be difficult and sometimes unsuccessful. Thorough diagnosis along with orthodontic treatment combining bone-supported anchorage and cantilever springs appears, in our view, to offer the best solution to this tricky orthodontic challenge while limiting, as far as possible, the risk of failure. Copyright © 2015. Published by Elsevier Masson SAS.

  17. Mini-Implants in the Anchorage Armamentarium: New Paradigms in the Orthodontics

    Directory of Open Access Journals (Sweden)

    Masaru Yamaguchi

    2012-01-01

    Full Text Available Paradigms have started to shift in the orthodontic world since the introduction of mini-implants in the anchorage armamentarium. Various forms of skeletal anchorage, including miniscrews and miniplates, have been reported in the literature. Recently, great emphasis has been placed on the miniscrew type of temporary anchorage device (TAD. These devices are small, are implanted with a relatively simple surgical procedure, and increase the potential for better orthodontic results. Therefore, miniscrews not only free orthodontists from anchorage-demanding cases, but they also enable clinicians to have good control over tooth movement in 3 dimensions. The miniplate type also produces significant improvements in treatment outcomes and has widened the spectrum of orthodontics. The purpose of this paper is to update clinicians on the current concepts and versatile uses and clinical applications of skeletal anchorage in orthodontics.

  18. Use of miniplates as a method for orthodontic anchorage: a case report.

    Science.gov (United States)

    Peres, Fernando Gianzanti; Padovan, Luis Eduardo Marques; Kluppel, Leandro Eduardo; Albuquerque, Gustavo Calvalcanti; Souza, Paulo Cesar Ulson de; Claudino, Marcela

    2016-01-01

    Temporary anchorage devices (TADs) have been developed to be used as direct adjuncts in orthodontic treatment and have facilitated treatment of more complex orthodontic cases, including patients with dental impaction. This clinical case reports the applicability of TADs in the orthodontic treatment of a patient with impacted mandibular second molars. Surgical and orthodontic procedures related to the use of miniplates were also discussed in this study. The use of temporary anchorage devices, such as miniplates, can be suggested as an alternative to treat patients with impacted mandibular second molars.

  19. Transverse maxillary distraction in patients with periodontal pathology or insufficient tooth anchorage using custom-made devices.

    Science.gov (United States)

    Fernández-Sanromán, Jacinto; Donascimento, Montserrat González; López, Alberto Costas; Ferro, Martín Fernández; Berrondo, Ibon Almandoz

    2010-07-01

    We present our experience using modified Hyrax devices for treating transverse deficiencies of the maxilla in adult patients with periodontal pathology or insufficient tooth anchorage. The surgical technique, clinical indications, and results are discussed. Eight adult patients (6 females, 2 males) requiring maxillary expansion were studied prospectively between July 2002 and July 2007. All the patients had periodontal pathology or insufficient tooth anchorage preventing the use of conventional Hyrax devices. Patients underwent surgically assisted rapid maxillary expansion with the use of custom-made modified Hyrax devices (bone-borne or tooth-bone-borne devices). Patients received preoperatively (T1), at the end of distraction (T2), at removal of the expansion device (T3), and 12 months after surgery (T4) lateral and posterior anterior cephalograms and study models to measure the width of the anterior and posterior dental arches with a digital sliding calliper. Mean age was 28.5 years (range, 18-45 years). A significant widening of the anterior (6.3 +/- 1.6 mm) and posterior (7.1 +/- 1.2 mm) dental arches was demonstrated. No significant differences were found when comparing T3 with T4 measures. No significant complications were found. The results indicated that maxillary expansion with custom-made devices in adults was an easy, affordable, predictable and stable technique without significant complications in patients who suffer periodontal pathology or patients without enough dental support. Copyright 2010 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  20. Damage to the root after tooth movement towards a temporary anchorage device: An animal pilot study

    Directory of Open Access Journals (Sweden)

    Cheng-Tsung Huang

    2012-06-01

    Conclusions: A root moving towards a screw during OTM leads to crater-like damage. When time was allowed for healing, a trace of labeled cementum was found to have repaired the root surface, although a large portion of the concavity was filled in with alveolar bone, and the periodontal ligament space remained constant. A root moving against a screw produced excessive tipping. To avoid deviation from the predicted biomechanics and damage to the root, extra caution should be used to ensure the best benefits for patients when TADs are used interdentally for distalization of the dentition during orthodontic treatment.

  1. 78 FR 11099 - Safety Zone Within the Lower Portion of Anchorage #9, Mantua Creek Anchorage; Paulsboro, NJ

    Science.gov (United States)

    2013-02-15

    ... 1625-AA00 Safety Zone Within the Lower Portion of Anchorage 9, Mantua Creek Anchorage; Paulsboro, NJ... temporary safety zone around the southern one-third of Anchorage 9 (Mantua Creek Anchorage), below position 39[deg] 51.573 N-075[deg] 13.557 W due to dredging operations. The Dredge Florida will be working...

  2. Vacuum with mesh is a feasible temporary closure device after fascial dehiscence

    DEFF Research Database (Denmark)

    Bjørsum-Meyer, Thomas; Skarbye, Mona; Jensen, Kenneth Højsgaard

    2013-01-01

    INTRODUCTION: The open abdomen is a challenging condition and a temporary abdominal closure device is required in order to protect the intra-abdominal viscera. We aimed to evaluate the feasibility of a recent device: vacuum-assisted wound closure and mesh-mediated fascial traction (VAWCM) after f...

  3. Anchorage Areas

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — An anchorage area is a place where boats and ships can safely drop anchor. These areas are created in navigable waterways when ships and vessels require them for...

  4. Maxillary protraction in adult cleft lip and palate by a rigid external distraction device with dentoskeletal anchorage

    Science.gov (United States)

    Akarsu, Bengisu; Taner, Tulin; Tuncbilek, Gokhan; Mavili, M. Emin

    2012-01-01

    Objective: The objective is to evaluate the effects of maxillary distraction osteogenesis (DO) in an adult patient with unilateral cleft lip and palate (UCLP) by using a rigid external distraction (RED) device with dentoskeletal anchorage. Method: 31-year-old male patient with UCLP with severe maxillary hypoplasia, dolichofacial growth pattern, negative overjet and 1.5 mm openbite. After pre-surgical orthodontic treatment, an intra-oral appliance was modified to prevent extrusion of the molars and clockwise rotation of the mandible. Stainless steel plates were soldered bilaterally to the intra oral appliance at the level of canines. During surgery, miniplates were inserted in the maxillary segment and fixed to the plates of the intra oral appliance with screws. Results: The mean distraction length was 12 mm immediately after DO. SNA increased from 73o to 82o after distraction. A significant advancement of the maxilla and correction of the sagittal Class III skeletal relationship was achieved. The vertical position of the mandible and the face was kept stable, and the soft tissue profile became more balanced. Conclusion: This intra oral appliance design achieved desired skeletal changes during maxillary protraction with RED device in dolichofacial CLP patient. Occlusion and facial profile changes was found to be stable in 1-year follow-up. PMID:22509125

  5. Maxillary protraction in adult cleft lip and palate by a rigid external distraction device with dentoskeletal anchorage.

    Science.gov (United States)

    Akarsu, Bengisu; Taner, Tulin; Tuncbilek, Gokhan; Mavili, M Emin

    2012-04-01

    The objective is to evaluate the effects of maxillary distraction osteogenesis (DO) in an adult patient with unilateral cleft lip and palate (UCLP) by using a rigid external distraction (RED) device with dentoskeletal anchorage. 31-year-old male patient with UCLP with severe maxillary hypoplasia, dolichofacial growth pattern, negative overjet and 1.5 mm openbite. After pre-surgical orthodontic treatment, an intra-oral appliance was modified to prevent extrusion of the molars and clockwise rotation of the mandible. Stainless steel plates were soldered bilaterally to the intra oral appliance at the level of canines. During surgery, miniplates were inserted in the maxillary segment and fixed to the plates of the intra oral appliance with screws. The mean distraction length was 12 mm immediately after DO. SNA increased from 73o to 82o after distraction. A significant advancement of the maxilla and correction of the sagittal Class III skeletal relationship was achieved. The vertical position of the mandible and the face was kept stable, and the soft tissue profile became more balanced. This intra oral appliance design achieved desired skeletal changes during maxillary protraction with RED device in dolichofacial CLP patient. Occlusion and facial profile changes was found to be stable in 1-year follow-up.

  6. 78 FR 9010 - Dental Devices; Reclassification of Temporary Mandibular Condyle Prosthesis

    Science.gov (United States)

    2013-02-07

    .... FDA-2012-N-1239] Dental Devices; Reclassification of Temporary Mandibular Condyle Prosthesis AGENCY... condyle prostheses into class III, based on the recommendation of a Dental Products Panel (the Panel... Administration, Dental Products Advisory Panel Meeting Transcript, February 12, 1997; http://www.accessdata.fda...

  7. 78 FR 79308 - Dental Devices; Reclassification of Temporary Mandibular Condyle Prosthesis

    Science.gov (United States)

    2013-12-30

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration 21 CFR Part 872 [Docket No. FDA-2012-N-1239] Dental Devices; Reclassification of Temporary Mandibular Condyle Prosthesis AGENCY... delegated to the Commissioner of Food and Drugs, 21 CFR part 872 is amended as follows: PART 872--DENTAL...

  8. Impact of radiation history, gender and age on bone quality in sites for orthodontic skeletal anchorage device placement.

    Science.gov (United States)

    Konermann, A; Appel, T; Wenghoefer, M; Sirokay, S; Dirk, C; Jäger, A; Götz, W

    2015-05-01

    Stability of orthodontic miniscrew implants is prerequisite to their success and durability in orthodontic treatment. As investigations revealed a positive correlation of miniscrew stability to periimplant bone quality, it has been the aim of this study to analyze the bone structure of resection preparations of human mandibles histologically by investigating the samples according to age, gender and exposure to radiotherapy. Inflammation- and tumor-free alveolar bone sections from human mandibles (n = 31) with previously diagnosed carcinoma, chronic osteomyelitis or cysts were analyzed histomorphologically and histomorphometrically as to the dimension of trabeculae in cancellous areas. Group A investigated the impact of a history of radiation therapy, group B of gender and group C contrasted biopsies from individuals aging under 60 or over 60 years. Statistics were performed using the Kruskal-Wallis-test. Radiation, gender and age did not significantly influence bone density. The mean bone density averaged 40.7 ± 15.0% of spongiosa for the total collective with a median age of 58.4 years ± 14.7 years. Our findings provide new information on bone quality, thus contributing to a more precise evaluation of the parameters affecting and those not affecting miniscrew implant stability. On the basis of these results, the formulation of clinical guidelines for risk assessment of therapeutic approaches in patients prior to insertion of orthodontic skeletal anchorage devices seems to be conceivable. Copyright © 2014 Elsevier GmbH. All rights reserved.

  9. Treatment of Obstructive Sleep Apnea Using Temporary Mandible Advancement Device: A Case Report

    Directory of Open Access Journals (Sweden)

    Young-Chan Choi

    2015-06-01

    Full Text Available Obstructive sleep apnea (OSA is the most prevalent type of sleep apnea, and oral appliance may be one of the options for treatment of OSA. But, the problems with the oral appliance are high cost, possible low compliance, and complications such as temporomandibular disorder. In this article, we described a severe OSA case that was successfully improved by using temporary mandible advancement device, which was designed for therapeutic effect of mandible advancement with low cost and simplified fabrication procedure.

  10. Recovery of multiple impacted maxillary teeth in a hyperdivergent Class I patient using Temporary Skeletal Anchorage Devices and augmented corticotomy.

    Science.gov (United States)

    Kim, Kyung A; Hwang, Hyeon-Shik; Chung, Kyu-Rhim; Kim, Seong-Hun; Nelson, Gerald

    2018-01-01

    Treatment of multiple impacted teeth is challenging. Three-dimensional treatment planning can help in delivering a better outcome. This case report presents a patient with an incomplete dental transposition between the canine and lateral incisor of the maxillary right side associated with the impaction of a dilacerated right central incisor. Using a two-stage surgical exposure and augmented corticotomy, the patient's occlusion and smile esthetics were significantly improved, and Class I occlusal relationships with optimal overjet and overbite were achieved after 50 months of orthodontic treatment. Thirty-month posttreatment records revealed a stable result.

  11. Effectiveness of 3 methods of anchorage reinforcement for maximum anchorage in adolescents: A 3-arm multicenter randomized clinical trial.

    Science.gov (United States)

    Sandler, Jonathan; Murray, Alison; Thiruvenkatachari, Badri; Gutierrez, Rodrigo; Speight, Paul; O'Brien, Kevin

    2014-07-01

    The objective of this 3-arm parallel randomized clinical trial was to compare the effectiveness of temporary anchorage devices (TADs), Nance button palatal arches, and headgear for anchorage supplementation in the treatment of patients with malocclusions that required maximum anchorage. This trial was conducted between August 2008 and February 2013 in 2 orthodontic departments in the United Kingdom. The study included 78 patients (ages, 12-18 years; mean age, 14.2 years) who needed maximum anchorage. Eligibility criteria included no active caries, exemplary oral hygiene, and maximum anchorage required. The primary outcome was mesial molar movement during the period in which anchorage supplementation was required. The secondary outcomes were duration of anchorage reinforcement, number of treatment visits, number of casual and failed appointments, total treatment time, dento-occlusal change, and patients' perceptions of the method of anchorage supplementation. Treatment allocation was implemented by contacting via the Internet the randomization center at the University of Nottingham, Clinical Trials Unit. The randomization was based on a computer-generated pseudo-random code with random permuted blocks of randomly varying size. A research assistant who was blinded to the group allocation recorded all data. The patients were randomly allocated to receive anchorage supplementation with TADs, a Nance button on a palatal arch, or headgear. They were all treated with maxillary and mandibular preadjusted edgewise fixed appliances with 0.022-in slot prescription brackets. They were followed until orthodontic treatment was complete. Seventy-eight patients were randomized in a 1:1:1 ratio among the 3 groups. The baseline characteristics were similar in the groups, and they were treated for an average of 27.4 months (SD, 7.1 months); 71 completed orthodontic treatment. The data were analyzed on a per-protocol basis and showed no differences in the effectiveness of anchorage

  12. [Skeletal anchorage in the past, today and tomorrow].

    Science.gov (United States)

    Melsen, Birte; Dalstra, Michel

    2017-03-01

    Skeletal anchorage was not introduced as an alternative to conventional anchorage modalities. The first skeletal anchorage was a ligature through a hole in the infrazygomatic crest. This was replaced by surgical screws and finally the TADs, which were optimized with respect to the material and morphology, were developed. A bracket-like head allows for the use of the mini-implant as indirect anchorage, but should not be a tool for lost control resulting from badly planned biomechanics or failing compliance. Skeletal anchorage should serve as an adjunct to correct biomechanics, to enable treatments that could not be performed prior to the introduction of skeletal anchorage. The aim of this study was to test the hypothesis that temporary anchorage mini-screws help maintain bone density, height and width of alveolar processes in the extraction sites, and thus prevent the thinning of the alveolar ridge usually observed. In adult patients with degenerated dentitions the application of skeletal anchorage can allow for the displacement of teeth where no anchorage units are present, but also for the redevelopment and maintenance of atrophic alveolar bone. The basis for the optimal use of skeletal anchorage is that the correct line of action for the desired tooth displacement is defined and the necessary force system constructed either with the skeletal anchorage as direct or as indirect anchorage. After a period, during which osseointegrated implants were used as anchorage for tooth movement and bone maintenance, it was accepted that the mini-implants could serve also as anchorage for skeletal displacements avoiding loading of teeth. © EDP Sciences, SFODF, 2017.

  13. Indian Board of Orthodontics case report: Orthodontic management of vertical excess using skeletal anchorage

    Directory of Open Access Journals (Sweden)

    Ajit J Kalia

    2016-01-01

    Full Text Available B.B., a 21-year-old girl, presented with the chief complaint of forwardly placed upper front teeth and gummy smile. Diagnosis revealed prognathic maxilla and average mandible, Class II skeletal base with vertical growth pattern, end-on molars and Class II canine relationship bilaterally, convex profile, potentially incompetent lips, gummy smile, and protrusive lower lip. The patient′s treatment plan was extraction of all first bicuspids and retraction using temporary anchorage devices. Anchorage was reinforced using microimplants in the maxillary arch and second molar banding in the mandibular arch. The implants were placed high up in the vestibule to have more of an intrusive component and to reduce gummy smile at the end of the treatment.

  14. Temporary abdominal closure with zipper-mesh device for management of intra-abdominal sepsis

    Directory of Open Access Journals (Sweden)

    Edivaldo Massazo Utiyama

    Full Text Available OBJECTIVE: to present our experience with scheduled reoperations in 15 patients with intra-abdominal sepsis. METHODS: we have applied a more effective technique consisting of temporary abdominal closure with a nylon mesh sheet containing a zipper. We performed reoperations in the operating room under general anesthesia at an average interval of 84 hours. The revision consisted of debridement of necrotic material and vigorous lavage of the involved peritoneal area. The mean age of patients was 38.7 years (range, 15 to 72 years; 11 patients were male, and four were female. RESULTS: forty percent of infections were due to necrotizing pancreatitis. Sixty percent were due to perforation of the intestinal viscus secondary to inflammation, vascular occlusion or trauma. We performed a total of 48 reoperations, an average of 3.2 surgeries per patient. The mesh-zipper device was left in place for an average of 13 days. An intestinal ostomy was present adjacent to the zipper in four patients and did not present a problem for patient management. Mortality was 26.6%. No fistulas resulted from this technique. When intra-abdominal disease was under control, the mesh-zipper device was removed, and the fascia was closed in all patients. In three patients, the wound was closed primarily, and in 12 it was allowed to close by secondary intent. Two patients developed hernia; one was incisional and one was in the drain incision. CONCLUSION: the planned reoperation for manual lavage and debridement of the abdomen through a nylon mesh-zipper combination was rapid, simple, and well-tolerated. It permitted effective management of severe septic peritonitis, easy wound care and primary closure of the abdominal wall.

  15. Bone anchorage: When and why?

    OpenAIRE

    Ahmet Nejat Erverdi

    2015-01-01

    Anchorage is the most important concept in biomechanics of orthodontics. In contemporary orthodontics, bone anchorage is a magic tool, which decreased the indication for extraoral appliances greatly and at the same time achieving stationary anchorage became possible. However, the indication for bone anchorage has to be clarified carefully. Skeletal open-bite treatment, effective molar distalization, Class III treatment by using chin anchorage, and space closure in severe minimal anchorage cas...

  16. Bone anchorage: When and why?

    Directory of Open Access Journals (Sweden)

    Ahmet Nejat Erverdi

    2015-01-01

    Full Text Available Anchorage is the most important concept in biomechanics of orthodontics. In contemporary orthodontics, bone anchorage is a magic tool, which decreased the indication for extraoral appliances greatly and at the same time achieving stationary anchorage became possible. However, the indication for bone anchorage has to be clarified carefully. Skeletal open-bite treatment, effective molar distalization, Class III treatment by using chin anchorage, and space closure in severe minimal anchorage cases are some examples for bone anchorage supported orthodontic treatment. Here, we discussed three necessary usages of bone anchorage for different treatment modalities.

  17. TERRAIN, Anchorage, Alaska

    Data.gov (United States)

    Federal Emergency Management Agency, Department of Homeland Security — The Anchorage AOI consists of seven areas. These areas were to be collected to the 'highest' accuracy requirement. Ground Control is collected throughout the AOI for...

  18. The benefit of differential moment concept in managing posterior anchorage and avoiding bite deepening

    Directory of Open Access Journals (Sweden)

    Harryanto Wijaya

    2012-09-01

    Full Text Available Background: Anchorage is one of the major concerns in orthodontic space closure. Various methods have been proposed to enhance posterior anchorage in space closure such as headgear, Nance holding appliance, and micro implant as temporary anchorage devices. However, several issues such as patient's compliance, appliance effectiveness, and cost of the device become many clinicians concern. The differential moment concept in segmented arch is a technique that requires no patient compliance but can effectively manage posterior anchorage and avoid bite deepening by careful application of forces and moments. Purpose: The purpose of this case report is to show the use of differential moment concept in segmented arch technique to manage posterior anchorage and to avoid bite deepening. Case: A 21 years old female patient with protrusive teeth as her chief complaint was treated using fixed orthodontic appliance. Case management: The treatment included four first bicuspid extraction and space closure utilizing differential moment concept in segmented arch. Conclusion: It can be concluded that application of differential moment concept in segmented arch technique is a non invasive, compliance independent, effective, and cost efficient method to manage posterior anchorage and to avoid bite deepening.latar belakang: Penjangkaran merupakan salah satu aspek yang sering kali menjadi masalah dalam penutupan ruang pada perawatan ortodonti. Berbagai metode disarankan untuk memperkuat penjangkaran posterior dalam penutupan ruang seperti headgear, piranti penahan Nance, dan implan mikro sebagai alat penjangkar sementara. Namun demikian, beberapa hal seperti kerjasama pasien, efektivitas piranti, dan biaya dari alat-alat tersebut sering menjadi perhatian/pertimbangan bagi klinisi. Konsep momen diferensial pada segmented arch adalah suatu cara yang efektif untuk memperkuat penjangkaran dan menghindari pendalaman gigitan tanpa memerlukan kerjasama pasien. tujuan

  19. Follow-up of Temporary Implantable Nitinol Device (TIND) Implantation for the Treatment of BPH: a Systematic Review.

    Science.gov (United States)

    Bertolo, Riccardo; Fiori, Cristian; Amparore, Daniele; Porpiglia, Francesco

    2018-04-26

    The purpose of the present systematic review is to offer a narrative synthesis of the available literature regarding the role of the temporary implantable nitinol device (TIND) (Medi-Tate®; Medi-Tate Ltd., Or Akiva, Israel) for the treatment of benign prostatic hyperplasia (BPH)-related lower urinary tract symptoms (LUTS), specifically focusing on the follow-up data. Current available evidences are limited in this topic. Sample size of patients available for analysis is small. Moreover, the duration of follow-up period is intermediate and longer follow-up is required. At the available 3 years follow-up, the TIND implantation is safe, effective, and well tolerated. The extended follow-up of the first and only available cohort of patients who underwent TIND for LUTS related to BPH corroborated previous literature findings. Further studies are required in order to assess the durability of TIND outcomes over a longer follow-up, to better define the indications of this approach, and to demonstrate the advantages of second-generation device over the first.

  20. Bridge to transplantation using paracorporeal biventricular assist devices or the syncardia temporary total artificial heart: is there a difference?

    Science.gov (United States)

    Nguyen, A; Pozzi, M; Mastroianni, C; Léger, P; Loisance, D; Pavie, A; Leprince, P; Kirsch, M

    2015-06-01

    Biventricular support can be achieved using paracorporeal ventricular assist devices (p-BiVAD) or the Syncardia temporary total artificial heart (t-TAH). The purpose of the present study was to compare survival and morbidity between these devices. Data from 2 French neighboring hospitals were reviewed. Between 1996 and 2009, 148 patients (67 p-BiVADs and 81 t-TAH) underwent primary, planned biventricular support. There were 128 (86%) males aged 44±13 years. Preoperatively, p-BiVAD recipients had significantly lower systolic and diastolic blood pressures, more severe hepatic cytolysis and higher white blood cell counts than t-TAH recipients. In contrast, t-TAH patients had significantly higher rates of pre-implant ECLS and hemofiltration. Mean support duration was 79±100 days for the p-BiVAD group and 71±92 for t-TAH group (P=0.6). Forty two (63%) p-BiVAD recipients were bridged to transplantation (39, 58%) or recovery (3, 5%), whereas 51 (63%) patients underwent transplantation in the t-TAH group. Death on support was similar between groups (p-BiVAD, 26 (39%); t-TAH, 30 (37%); P=0.87). Survival while on device was not significantly different between patient groups and multivariate analysis showed that only preimplant diastolic blood pressure and alanine amino-transferase levels were significant predictors of death. Post-transplant survival in the p-BiVAD group was 76±7%, 70±8%, and 58±9% at 1, 3, and 5 years after transplantation, respectively, and was similar to that of the t-TAH group (77±6%, 72±6%, and 70±7%, P=0.60). Survival while on support and up to 5 years after heart transplantation was not significantly different in patients supported by p-BiVADs or t-TAH. Multivariate analysis revealed that survival while on transplantation was not affected by the type of device implanted.

  1. Implants for orthodontic anchorage

    Science.gov (United States)

    Zheng, Xiaowen; Sun, Yannan; Zhang, Yimei; Cai, Ting; Sun, Feng; Lin, Jiuxiang

    2018-01-01

    Abstract Implantanchorage continues to receive much attention as an important orthodontic anchorage. Since the development of orthodontic implants, the scope of applications has continued to increase. Although multiple reviews detailing implants have been published, no comprehensive evaluations have been performed. Thus, the purpose of this study was to comprehensively evaluate the effects of implants based on data published in review articles. An electronic search of the Cochrane Library, Medline, Embase, Ebsco and Sicencedirect for reviews with “orthodontic” and “systematic review or meta analysis” in the title, abstract, keywords, or full text was performed. A subsequent manual search was then performed to identify reviews concerning orthodontic implants. A manual search of the orthodontic journals American Journal of Orthodontics and Dentofacial Orthopedics (AJODO), European Journal of Orthodontics (EJO), and Angle Othodontist was also performed. Such systematic reviews that evaluated the efficacy and safety of orthodontic implants were used to indicate success rates and molar movements. A total of 23 reviews were included in the analysis. The quality of each review was assessed using a measurement tool for Assessment of Multiple Systematic Reviews (AMSTAR), and the review chosen to summarize outcomes had a quality score of >6. Most reviews were less than moderate quality. Success rates of implants ranged in a broad scope, and movement of the maxillary first molar was superior with implants compared with traditional anchorage. PMID:29595673

  2. Friction and anchorage loading revisited.

    Science.gov (United States)

    Dholakia, Kartik D

    2012-01-01

    Contemporary concepts of sliding mechanics explain that friction is inevitable. To overcome this frictional resistance, excess force is required to retract the tooth along the archwire (ie, individual retraction of canines, en masse retraction of anterior teeth), in addition to the amount of force required for tooth movement. The anterior tooth retraction force, in addition to excess force (to overcome friction), produces reciprocal protraction force on molars, thereby leading to increased anchorage loading. However, this traditional concept was challenged in recent literature, which was based on the finite element model, but did not bear correlation to the clinical scenario. This article will reinforce the fact that clinically, friction increases anchorage loading in all three planes of space, considering the fact that tooth movement is a quasistatic process rather than a purely continuous or static one, and that conventional ways of determining the effects of static or dynamic friction on anchorage load cannot be applied to clinical situations (which consist of anatomical resistance units and a complex muscular force system). The article does not aim to quantify friction and its effect on the amount of anchorage load. Rather, a new perspective regarding the role of various additional factors (which is not explained by contemporary concept) that may influence friction and anchorage loading is provided..

  3. Anchorage strategies in geriatric hip fracture management

    Directory of Open Access Journals (Sweden)

    Knobe Matthias

    2016-12-01

    Full Text Available There is an enormous humanitarian and socioeconomic need to improve the quality and effectiveness of care for patients with hip fracture. To reduce mechanical complications in the osteosynthesis of proximal femoral fractures, improved fixation techniques have been developed including blade or screw-anchor devices, locked minimally invasive or cement augmentation strategies. However, despite numerous innovations and advances regarding implant design and surgical techniques, systemic and mechanical complication rates remain high. Treatment success depends on secure implant fixation in often-osteoporotic bone as well as on patient-specific factors (fracture stability, bone quality, comorbidity, and gender and surgeon-related factors (experience, correct reduction, and optimal screw placement in the head/neck fragment. For fracture fixation, the anchorage of the lag screw within the femoral head plays a crucial role depending on the implant’s design. Meta-analyses and randomized controlled studies demonstrate that there is a strong trend towards arthroplasty treating geriatric femoral neck fractures. However, for young adults as well as older patients with less compromised bone quality, or in undisplaced fractures, head-preserving therapy is preferred as it is less invasive and associated with good functional results. This review summarizes the evidence for the internal fixation of femoral neck fractures and trochanteric femoral fractures in elderly patients. In addition, biomechanical considerations regarding implant anchorage in the femoral head including rotation, migration, and femoral neck shortening are made. Finally, cement augmentation strategies for hip fracture implants are evaluated critically.

  4. 21 CFR 872.3770 - Temporary crown and bridge resin.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Temporary crown and bridge resin. 872.3770 Section... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3770 Temporary crown and bridge resin. (a) Identification. A temporary crown and bridge resin is a device composed of a material, such as...

  5. Temporary Termination.

    Science.gov (United States)

    Seligman, Linda

    1984-01-01

    Presents a method for helping clients deal productively with temporary intervals in counseling relationships that may be caused by either counselor or client vacations or trips. Advocates developing goals, providing an opportunity for continued communication, referrals, processing of accomplishments, and scheduling the next session. (LLL)

  6. Temporary workers

    NARCIS (Netherlands)

    Klein Hesselink, J.; Verbiest, S.; Goudswaard, A.

    2014-01-01

    Temporary employment contracts are often used by employers to manage fluctuations in personnel needs. Many sectors of industry experience these fluctuations, which are often seasonal. This creates uncertainty about the continuousness of demand for work, which is transferred from employers to

  7. Inspection Mechanism and Experimental Study of Prestressed Reverse Tension Method under PC Beam Bridge Anchorage

    Science.gov (United States)

    Peng, Zhang

    2018-03-01

    the prestress under anchorage is directly related to the structural security and performance of PC beam bridge. The reverse tension method is a kind of inspection which confirms the prestress by exerting reversed tension load on the exposed prestressing tendon of beam bridge anchoring system. The thesis elaborately expounds the inspection mechanism and mechanical effect of reverse tension method, theoretically analyzes the influential elements of inspection like tool anchorage deformation, compression of conjuncture, device glide, friction of anchorage loop mouth and elastic compression of concrete, and then presents the following formula to calculate prestress under anchorage. On the basis of model experiment, the thesis systematically studies some key issues during the reverse tension process of PC beam bridge anchorage system like the formation of stress-elongation curve, influential factors, judgment method of prestress under anchorage, variation trend and compensation scale, verifies the accuracy of mechanism analysis and demonstrates: the prestress under anchorage is less than or equal to 75% of the ultimate strength of prestressing tendon, the error of inspect result is less than 1%, which can meet with the demands of construction. The research result has provided theoretical basis and technical foundation for the promotion and application of reverse tension in bridge construction.

  8. Towards a workflow driven design for mHealth devices within temporary eye clinics in low-income settings.

    Science.gov (United States)

    Bolster, Nigel M; Bastawrous, Andrew; Giardini, Mario E

    2015-01-01

    Only a small minority of mobile healthcare technologies that have been successful in pilot studies have subsequently been integrated into healthcare systems. Understanding the reasons behind this discrepancy is crucial if such technologies are to be adopted. We believe that the mismatch is due to a breakdown in the relation between technical soundness of the original mobile health (mHealth) device design, and integration into healthcare provision workflows. Quantitative workflow modelling provides an opportunity to test this hypothesis. In this paper we present our current progress in developing a clinical workflow model for mobile eye assessment in low-income settings. We test the model for determining the appropriateness of design parameters of a mHealth device within this workflow, by assessing their impact on the entire clinical workflow performance.

  9. 29 CFR 1926.755 - Column anchorage.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 8 2010-07-01 2010-07-01 false Column anchorage. 1926.755 Section 1926.755 Labor... (CONTINUED) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Steel Erection § 1926.755 Column anchorage. (a) General requirements for erection stability. (1) All columns shall be anchored by a minimum of 4 anchor...

  10. Orthodontic Anchorage Implants: State-of-the-art

    DEFF Research Database (Denmark)

    Melsen, Birte

    2007-01-01

    The limits of an orthodontic treatment are often set by the lack of suitable anchorage. The mini-implant is used where conventional anchorage cannot be applied and not as a replacement for conventional anchorage. In patients with lack of teeth and reduced periodontium, skeletal anchorage allows...... will improve the reconstruction possibilities. The mini-implant has widened the orthodontic possibilities....

  11. On decisive factors of liner anchorage behaviour

    International Nuclear Information System (INIS)

    Bucchardt, F.; Weber, M.; Yazdi, F.

    1984-01-01

    Design of reinforced and prestressed containments for nuclear power plants in the FRG shall be guided by DIN 25459; this also includes the structural behaviour of the liner. While the containment safety analysis is a more global matter, the liner and especially the liner anchorage behaviour concentrates on local effects which need a more refined local area description. Due to the predominant stiffness of the concrete structure liner failure analysis are performed by decoupling the steel membrane which is then only supported by anchorage springs. A comprehensive nonlinear analytical study is carried out to examine the anchorage behaviour. (Author) [pt

  12. Advances in cell culture: anchorage dependence

    Science.gov (United States)

    Merten, Otto-Wilhelm

    2015-01-01

    Anchorage-dependent cells are of great interest for various biotechnological applications. (i) They represent a formidable production means of viruses for vaccination purposes at very large scales (in 1000–6000 l reactors) using microcarriers, and in the last decade many more novel viral vaccines have been developed using this production technology. (ii) With the advent of stem cells and their use/potential use in clinics for cell therapy and regenerative medicine purposes, the development of novel culture devices and technologies for adherent cells has accelerated greatly with a view to the large-scale expansion of these cells. Presently, the really scalable systems—microcarrier/microcarrier-clump cultures using stirred-tank reactors—for the expansion of stem cells are still in their infancy. Only laboratory scale reactors of maximally 2.5 l working volume have been evaluated because thorough knowledge and basic understanding of critical issues with respect to cell expansion while retaining pluripotency and differentiation potential, and the impact of the culture environment on stem cell fate, etc., are still lacking and require further studies. This article gives an overview on critical issues common to all cell culture systems for adherent cells as well as specifics for different types of stem cells in view of small- and large-scale cell expansion and production processes. PMID:25533097

  13. 77 FR 6010 - Anchorage Regulations; Newport, RI

    Science.gov (United States)

    2012-02-07

    ... anchor up to three cruise ships simultaneously in anchorage ``D''. For the convenience and safety of..., design, or operation; test methods; sampling procedures; and related management systems practices) that...

  14. 76 FR 59596 - Anchorage Regulations; Newport, RI

    Science.gov (United States)

    2011-09-27

    ... up to three cruise ships simultaneously in anchorage ``D''. For the convenience and safety of... standards (e.g., specifications of materials, performance, design, or operation; test methods; sampling...

  15. A comparitive clinical study between self tapping and drill free screws as a source of rigid orthodontic anchorage.

    Science.gov (United States)

    Gupta, Nishant; Kotrashetti, S M; Naik, Vijay

    2012-03-01

    Self-tapping miniscrews are commonly being used as a temporary anchorage device for orthodontic purpose. A prerequisite for the insertion of these screws is the preparation of a pilot hole, which is time consuming and may result in damage to nerves, tooth root, drill bit breakage and thermal necrosis of bone. On the other hand the design of drill-free screws enables them to be inserted without drilling. The aim of this prospective study was to compare the stability and clinical response of the soft tissue around the self tapping and drill free screws when used for orthodontic anchorage for en mass retraction of maxillary anterior teeth. The study sample consisted of 20 patients requiring retraction of maxillary anterior teeth. The screws were placed in the alveolar bone between maxillary 2nd premolar and 1st molar bilaterally at the junction of attached gingiva and moveable mucosa. Pilot hole was drilled on the side which was selected for insertion of the self tapping screw under copious irrigation, after which it was inserted. Drill free screw was inserted on the contralateral side without predrilling. All screws were immediately loaded with 150-200 gm of retraction force. Patients were recalled for regular follow up for a period of 6 months. If the screws became mobile or showed any signs of inflammation during the course of the study, they were considered to be a failure. After a period of 6 months an overall success rate of 77.5% was noted. Four self tapping and five drill-free screws failed during the study. There was no statistically significant difference between the two types of screws with respect to success/failure. Mobility was found to be the major cause for the failure. Both self-tapping and the drill-free screws are effective anchorage units. But the latter have an edge over the conventional self-tapping screws because of decrease in operative time, little bone debris, less thermal damage, lower morbidity, and minimal patient discomfort as

  16. Biofilm formation on surface characterized micro-implants for skeletal anchorage in orthodontics

    NARCIS (Netherlands)

    Chin, Yeen; Sandham, John; de Vries, Jacob; van der Mei, Henderina; Busscher, Hendrik

    Micro-implants are increasingly popular in clinical orthodontics to effect skeletal anchorage. However, biofilm formation on their surfaces and subsequent infection of peri-implant tissues can result in either exfoliation or surgical removal of these devices. The present study aimed to assess

  17. Performance of Sequoyah Containment Anchorage System

    International Nuclear Information System (INIS)

    Fanous, F.; Greimann, L.; Wassef, W.; Bluhm, D.

    1993-01-01

    Deformation of a steel containment anchorage system during a severe accident may result in a leakage path at the containment boundaries. Current design criteria are based on either ductile or brittle failure modes of headed bolts that do not account for factors such as cracking of the containment basemat or deformation of the anchor bolt that may affect the behavior of the containment anchorage system. The purpose of this study was to investigate the performance of a typical ice condenser containment's anchorage system. This was accomplished by analyzing the Sequoyah Containment Anchorage System. Based on a strength of materials approach and assuming that the anchor bolts are resisting the uplift caused by the internal pressure, one can estimate that the failure of the anchor bolts would occur at a containment pressure of 79 psig. To verify these results and to calibrate the strength of materials equation, the Sequoyah containment anchorage system was analyzed with the ABAQUS program using a three-dimensional, finite-element model. The model included portions of the steel containment building, shield building, anchor bolt assembly, reinforced concrete mat and soil foundation material

  18. Is skeletal anchorage changing the limit of orthodontics?

    DEFF Research Database (Denmark)

    Melsen, Birte

    2007-01-01

    The limits for orthodontic treatment are often set by the lack of suitable anchorage. The mini-implant is used where conventional anchorage cannot be applied; not as a replacement for conventional anchorage. In patients with lack of teeth and reduced periodontium, skeletal anchorage allows...... and can be loaded immediately. The course will be addressed the following topics: Are the mini-implants replacing conventional anchorage? Why are orthodontic mini-implants necessary? The development of the skeletal anchorage systems The biological basis for the skeletal anchorage systems...... The characteristics of the different skeletal anchorage systems The insertion procedure The indications for the use of orthodontic mini-implants Treatment planning in relation to the use of mini-implants Case presentations...

  19. Paradigm shifts in orthodontic treatment with mini-implant anchorage

    Directory of Open Access Journals (Sweden)

    Johnny Joung-Lin Liaw

    2015-01-01

    Full Text Available After the applications of mini-implant anchorage, the envelope of orthodontic treatment was expanded and some treatment modes were changed because of more predictable tooth movement with empowered anchorage. The author tried to share his experience of TADs applications for clarifying the paradigm shifts of orthodontic treatment assisted with the mini-implant anchorage.

  20. Seismic verification of nuclear plant equipment anchorage

    International Nuclear Information System (INIS)

    Lepiece, M.; Van Vyve, J.

    1991-01-01

    More than 60% of the electrical power of Belgium is generated by seven PWR nuclear power plants. For three of them, the electro-mechanical equipment had to be reassessed after ten years of operation, because the seismic requirements were upgraded from 0.1 g to 0.17 g free field ground acceleration. The seismic requalification of the active equipment was a critical problem as the classical methods were too conservative. The approach based on the use of the past experience on the seismic behavior of nonnuclear equipment, chosen and developed by the SQUG, had to be transposed to the Belgian N.P.P. The decision of the accept-ability of equipment relies heavily on the aseismatic capacity of anchorage. The Electrical Power Research Institute (EPRI) developed the procedure and guideline for the demonstration of the aseismatic adequacy of equipment anchorage in a cost-effective and consistent manner, to support the decision by Seismic Review Team. The field inspection procedure to identify the type of fasteners and detect their possible defects and the verification procedure developed to calculate the aseismatic capacity of equipment anchorage on the strength of fasteners, the aseismatic capacity of anchorage and the comparison of the capacity with the demand are reported. (K.I.)

  1. 21 CFR 870.3680 - Cardiovascular permanent or temporary pacemaker electrode.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Cardiovascular permanent or temporary pacemaker... § 870.3680 Cardiovascular permanent or temporary pacemaker electrode. (a) Temporary pacemaker electrode—(1) Identification. A temporary pacemaker electrode is a device consisting of flexible insulated...

  2. Procedures adopted by orthodontists for space closure and anchorage control

    Directory of Open Access Journals (Sweden)

    André da Costa Monini

    2013-12-01

    Full Text Available OBJECTIVE: The aim of this study was to identify the procedures adopted by Brazilian orthodontists in the following situations: extraction space closure, anchorage control in case of necessary anchorage for group A and frequency of skeletal anchorage use, especially in the upper jaw. METHOD: A questionnaire was sent to the e-mail address of all dentists registered in the Brazilian Federal Council of Dentistry. RESULTS: The results showed that most Brazilian orthodontists usually perform extraction space closure by means of sliding mechanics. The use of palatal bar, inclusion of second molars in the archwire and space closure performed in two phases are the most used techniques for anchorage control in the upper jaw. The skeletal anchorage is referenced by 36.5% of specialists as a routine practice for the upper jaw anchorage. CONCLUSIONS: There is a wide variety of procedures adopted by Brazilian orthodontists for orthodontic space closure and anchorage control.

  3. Procedures adopted by orthodontists for space closure and anchorage control.

    Science.gov (United States)

    Monini, André da Costa; Gandini Júnior, Luiz Gonzaga; dos Santos-Pinto, Ary; Maia, Luiz Guilherme Martins; Rodrigues, Willian Caetano

    2013-01-01

    The aim of this study was to identify the procedures adopted by Brazilian orthodontists in the following situations: extraction space closure, anchorage control in case of necessary anchorage for group A and frequency of skeletal anchorage use, especially in the upper jaw. A questionnaire was sent to the e-mail address of all dentists registered in the Brazilian Federal Council of Dentistry. The results showed that most Brazilian orthodontists usually perform extraction space closure by means of sliding mechanics. The use of palatal bar, inclusion of second molars in the archwire and space closure performed in two phases are the most used techniques for anchorage control in the upper jaw. The skeletal anchorage is referenced by 36.5% of specialists as a routine practice for the upper arch anchorage. There is a wide variety of procedures adopted by Brazilian orthodontists for orthodontic space closure and anchorage control.

  4. Temporary implantable nitinol device (TIND): a novel, minimally invasive treatment for relief of lower urinary tract symptoms (LUTS) related to benign prostatic hyperplasia (BPH): feasibility, safety and functional results at 1 year of follow-up.

    Science.gov (United States)

    Porpiglia, Francesco; Fiori, Cristian; Bertolo, Riccardo; Garrou, Diletta; Cattaneo, Giovanni; Amparore, Daniele

    2015-08-01

    To report the first clinical experience with a temporary implantable nitinol device (TIND; Medi-Tate(®) ) for the treatment of lower urinary tract symptoms (LUTS) due to benign prostatic hyperplasia (BPH). In all, 32 patients with LUTS were enrolled in this prospective study, which was approved by our Institutional Ethics Committee. Inclusion criteria were: age >50 years, International Prostate Symptom Score (IPSS) of ≥10, maximum urinary flow rate (Qmax ) of ≤12 mL/s, and prostate volume of BPH. TIND implantation is a feasible and safe minimally invasive option for the treatment of BPH-related LUTS. The functional results are encouraging and the treatment significantly improved patient QoL. Further studies are required to assess durability of TIND results and to optimise the indications of such a procedure. © 2014 The Authors BJU International © 2014 BJU International Published by John Wiley & Sons Ltd.

  5. Procedures adopted by orthodontists for space closure and anchorage control

    OpenAIRE

    Monini,André da Costa; Gandini Júnior,Luiz Gonzaga; Santos-Pinto,Ary dos; Maia,Luiz Guilherme Martins; Rodrigues,Willian Caetano

    2013-01-01

    OBJECTIVE: The aim of this study was to identify the procedures adopted by Brazilian orthodontists in the following situations: extraction space closure, anchorage control in case of necessary anchorage for group A and frequency of skeletal anchorage use, especially in the upper jaw. METHOD: A questionnaire was sent to the e-mail address of all dentists registered in the Brazilian Federal Council of Dentistry. RESULTS: The results showed that most Brazilian orthodontists usually perform extra...

  6. Cell cycle control by components of cell anchorage

    OpenAIRE

    Gad, Annica

    2005-01-01

    Extracellular factors, such as growth factors and cell anchorage to the extracellular matrix, control when and where cells may proliferate. This control is abolished when a normal cell transforms into a tumour cell. The control of cell proliferation by cell anchorage was elusive and less well studied than the control by growth factors. Therefore, we aimed to clarify at what points in the cell cycle and through which molecular mechanisms cell anchorage controls cell cycle pro...

  7. 1964 Great Alaska Earthquake: a photographic tour of Anchorage, Alaska

    Science.gov (United States)

    Thoms, Evan E.; Haeussler, Peter J.; Anderson, Rebecca D.; McGimsey, Robert G.

    2014-01-01

    , and small-scale maps, as well as links to slideshows of additional photographs and Google Street View™ scenes. Buildings in Anchorage that were severely damaged, sites of major landslides, and locations of post-earthquake engineering responses are highlighted. The web map can be used online as a virtual tour or in a physical self-guided tour using a web-enabled Global Positioning System (GPS) device. This publication serves the purpose of committing most of the content of the web map to a single distributable document. As such, some of the content differs from the online version.

  8. Assessing the Frequency and Material Consequences of Collisions with Vessels Lying at an Anchorage in Line with IALA iWrap MkII

    Directory of Open Access Journals (Sweden)

    Hans-Christoph Burmeister

    2014-03-01

    Full Text Available This paper proposes a collision model for ships underway and temporary objects as an extension to state-of-the-art maritime risk assessment like IALA iWrap MkII. It gives a brief review of frequency modeling's and consequence calculation theory as well as its applications, before it analogously derives a model to assess the risk of anchorage areas. Subsequently, its benefit is demonstrated by an example scenario.

  9. Technical note: subclavian artery misplacement of a 12F Shaldon catheter: percutaneous repair with a local closure device under temporary balloon tamponade; Technische Mitteilung: Entfernung eines fehlplatzierten 12F Shaldon Katheters aus der A. subclavia und Abdichtung mittels Verschlusssystem bei temporaerer Ballonblockade

    Energy Technology Data Exchange (ETDEWEB)

    Wildberger, J.E.; Katoh, M.; Guenther, R.W. [Klinik fuer Radiologische Diagnostik, RWTH Aachen (Germany); Fussen, R. [Anaesthesiologische Klinik, Medizinisches Zentrum Kreis Aachen GmbH (Germany)

    2006-06-15

    A case of subsequent percutaneous repair using a local closure device with a collagen block (VasoSeal {sup registered}) and temporary balloon tamponade after inadvertent subclavian artery misplacement of a 12F Shaldon catheter is reported. Balloon occlusion safely prevented displacement of collagen into the vascular lumen by occluding the 12F entry site. Furthermore, collagen-induced coagulation was facilitated. (orig.)

  10. 78 FR 59914 - Foreign-Trade Zone 160-Anchorage, Alaska; Application for Reorganization Under Alternative Site...

    Science.gov (United States)

    2013-09-30

    ...: Site 1 (56.89 acres)--the Port of Anchorage and Port of Anchorage Industrial Park, 1075 Dock Rd., 1076... acres)--619 East Ship Creek Ave., Anchorage; Site 6 (12.2 acres)-- Douglas Management Company, 660...

  11. Orthodontic treatment with skeletal anchorage system

    Directory of Open Access Journals (Sweden)

    Arya Brahmanta

    2011-06-01

    Full Text Available Background: Correction of class I malocclusion with bimaxillary dental protrusion and unilateral free end right upper ridge in adult patient is one of difficult biomechanical case in orthodontics. Due to this case that needs proper anchorage for upper incisor retraction with missing teeth in the right posterior segment. Purpose: The aim of this study to find an effective therapy for correction of bimaxillary protrusion with unilateral free and ridge. Case: A female patient, 36 year old complaining for the difficulty of lip closure due to severe bimaxillary protrusion with incompetence lip. Case management: Firstly correction of the maxillary and mandibular incisor proclination were done by extraction of the mandibular first premolar, the maxillary second premolar on left side and finally placement of miniplates implant in the zygomatic process on right side as an absolut anchorage. Conclusion: Skeletal anchorage system (SAS can be considered as an effective therapy for corection of bimaxillary protrusion with unilateral free end ridge.Latar belakang: Koreksi dari maloklusi klas I dari penderita dewasa yang disertai protrusi bimaksiler dengan kehilangan gigi posterior pada regio kanan atas merupakan salah satu kasus sulit untuk dikerjakan terutama berhubungan dengan biomekanik pergerakan giginya dalam perawatan ortodonti. Tujuan: Tujuan dari penulisan artikel ini adalah untuk menemukan terapi yang efektif untuk perbaikan protrusi bimaksiler dan kehilangan gigi posterior pada satu sisi. Kasus: Seorang penderita wanita usia 35 tahun datang dengan keluhan utama kesulitan untuk menutup mulut oleh karena gigi rahang atas dan rahang bawahnya maju dan bibirnya tidak kompeten. Tatalaksana kasus: Koreksi pada gigi insisivus rahang atas dan insisivus rahang bawah yang protrusi dilakukan dengan melakukan pencabutan terlebih dahulu pada gigi premolar pertama dirahang bawah sisi kanan dan sisi kiri serta pencabutan pada gigi premolar kedua di rahang atas sisi

  12. Impedance-Based Cable Force Monitoring in Tendon-Anchorage Using Portable PZT-Interface Technique

    Directory of Open Access Journals (Sweden)

    Thanh-Canh Huynh

    2014-01-01

    Full Text Available In this paper, a portable PZT interface for tension force monitoring in the cable-anchorage subsystem is developed. Firstly, the theoretical background of the impedance-based method is presented. A few damage evaluation approaches are outlined to quantify the variation of impedance signatures. Secondly, a portable PZT interface is designed to monitor impedance signatures from the cable-anchorage subsystem. One degree-of-freedom analytical model of the PZT interface is established to explain how to represent the loss of cable force from the change in the electromechanical impedance of the PZT interface as well as reducing the sensitive frequency band by implementing the interface device. Finally, the applicability of the proposed PZT-interface technique is experimentally evaluated for cable force-loss monitoring in a lab-scaled test structure.

  13. Application and Curative Effect of Micro-implant Anchorage in ...

    African Journals Online (AJOL)

    research hot spot in the Department of. Stomatology. Instead of taking teeth as the basis, as was previously the case, this new anchorage exerts the counteracting force of orthodontics on the jaw, thus completely avoiding the displacement of teeth. It solves a lot of problems existing in clinical anchorage. Micro - implant.

  14. The Temporary Leave Dilemma -

    DEFF Research Database (Denmark)

    Amilon, Anna

    2010-01-01

    Lone mothers have to take care of a sick child with little or no help from the child’s other parent and have to carry all costs connected to leave-taking. This paper empirically tests whether lone mothers take more temporary parental leave to care for sick children than partnered mothers...... and whether parental leave is associated with a signaling cost. The results from this study of Swedish mothers show that lone mothers use more temporary parental leave than partnered mothers. Further, within the group of lone mothers, those with higher socioeconomic status take less temporary parental leave...... than those with lower socioeconomic status, whereas no such differences are found within the group of partnered mothers. One possible interpretation is that signaling costs negatively influence the utilization of temporary parental leave for lone mothers....

  15. Explaining the democratic anchorage of governance networks

    DEFF Research Database (Denmark)

    Skelcher, Chris; Klijn, Erik-Hans; Kübler, Daniel

    2011-01-01

    Advances in understanding the democratic anchorage of governance networks require carefully designed and contextually grounded empirical analysis that take into account contextual factors. The article uses a conjectural framework to study the impact of the national democratic milieu...... on the relationship between network governance and representative institutions in four European countries: the United Kingdom, Switzerland, the Netherlands, and Denmark. The article shows that the distinction between majoritarian and consensus democracy as well as the varying strength of voluntary associations...... are important contextual factors that help explain cross-national differences in the relationship between governance networks and representative institutions. We conclude that a context of weak associationalism in majoritarian democracies facilitates the instrumentalization of networks by government actors...

  16. Finite element simulation and testing of ISW CFRP anchorage

    DEFF Research Database (Denmark)

    Schmidt, Jacob Wittrup; Goltermann, Per; Hertz, Kristian Dahl

    2013-01-01

    is modelled in the 3D finite Element program ABAQUS, just as digital image correlation (DIC) testing was performed to verify the finite element simulation. Also a new optimized design was produced to ensure that the finite element simulation and anchorage behaviour correlated well. It is seen....... This paper presents a novel mechanical integrated sleeve wedge anchorage which seem very promising when perusing the scope of ultimate utilization of CFRP 8mm rods (with a tension capacity of approximately 140kN). Compression transverse to the CFRP is evaluated to prevent premature failure. The anchorage...

  17. FRP tendon anchorage in post-tensioned concrete structures

    DEFF Research Database (Denmark)

    Schmidt, Jacob Wittrup; Täljsten, Björn; Bennitz, Anders

    2008-01-01

    effective Young´s modulus and the high stress capacity in the linear elastic range of the material. The use of external tendons increases the requirements on the anchorage systems. This is in particular important when using un-bonded tendon systems, where the anchorage and deviators are the only force...... transfer points. The demand for high capacity anchorage tendons is fulfilled for steel tendons, but no competitive mechanical anchor has yet been developed for FRP tendon. A new small, reliable and more user friendly anchor has to be developed, before FRP tendons can be utilized with all of its capacity...

  18. Temporary physical protection systems

    International Nuclear Information System (INIS)

    Williams, J.D.; Gangel, D.J.; Madsen, R.W.

    1991-01-01

    Terrorism and other aspects of world political instability have created a high demand for temporary physical protection systems within the nuclear materials management community. They can be used when vehicles carrying important assets are away from their permanent fixed site location, around areas where experiments are being temporarily conducted, around construction areas and one portions of a fixed site physical security system which is temporarily inoperable. Physical security systems can be grouped into four categories: tactical, portable, semi-permanent, and fixed. The resources and experience gained at Sandia National Laboratories in over forty years of developing and implementing security systems for protecting nuclear weapons and fixed nuclear facilities is now being applied to temporary physical security systems. This paper emphasizes temporary physical security systems and their component parts that are presently available and identify additional system-subsystem objectives, requirements, and concepts

  19. Temporary labour contracts

    CERN Document Server

    1999-01-01

    The five contracts for Temporary Labour assignments on the CERN site (L020/PE, L021/PE, L022/PE, L023/PE and L024/PE) approved by the Finance Committee in March 1996 (CERN/FC/3857) will reach the end of their initial three-year contractual period at the end of December 1999. Following the satisfactory execution of these contracts during this period, CERN requests approval to extend them from January 2000 for the first of the two years foreseen in the original adjudication. The Finance Committee is invited: - to take note that the three-year expenditure for Temporary Labour contracts from 1997 to 1999 will not exceed 19 100 000 Swiss francs, compared to the 18 900 000 Swiss francs estimated at the time of the adjudication in March 1996; - to approve an extension of the present Temporary Labour contracts for the year 2000 for a total amount not exceeding 6 000 000 Swiss francs.

  20. Temporary labour contracts

    CERN Document Server

    2001-01-01

    At its September 2000 meeting, the Finance Committee approved a second one-year extension of the four existing temporary labour contracts (L020/PE, L021/PE, L022/PE, L023/PE) until 31 December 2001 for a total amount not exceeding 6 000 000 Swiss francs at 2000 prices. The Finance Committee is invited: - to take note that the estimated annual expenditure on temporary labour in 2001 will amount to approximately 4 500 000 Swiss francs against the previously estimated 6 000 000 Swiss francs; - to approve the extension of the four existing contracts by six months to 30 June 2002 for an overall amount not exceeding 1 500 000 Swiss francs; - to take note that new contracts for the Swiss part of the CERN site will be submitted for adjudication in December 2001 and that new contracts for the French part of the CERN site will be submitted for adjudication in the course of 2002.

  1. Improved anchorage of steel linings at WWER nuclear power plants

    International Nuclear Information System (INIS)

    Bouda, M.; Cepicky, J.

    1987-01-01

    Three variants were tested of anchoring the steel lining of special structures of nuclear power plants with WWER reactors, such as the containment, viz.: point anchorage with pins according to a Czechoslovak design, and two methods of linear anchorage according to a Soviet design and a design by the Institute for Industrial Construction of the GDR. Graphically shown are some results of the tests of the point anchorage with pins that showed the reliability of the method with respect to deformation and strain of the lining and of the anchoring elements at a lining temperature of up to 300 degC, which significantly exceeded the design-basis accident temperature of 150 degC. The advantages of the variant include a lower content of labour and an increased quality of welding jobs thanks to the application of the Nelson semi-automatic welding technique. (Z.M.). 10 figs., 7 refs

  2. Modification of evaluation response spectrum by ductility of equipment anchorage

    International Nuclear Information System (INIS)

    Choi, I. G.; Jun, Y. S.; Su, J. M.

    2003-01-01

    The failure mode of welded anchorage is assumed as brittle in the seismic capacity evaluation of nuclear power plant equipments. But the welded anchorage has some ductile capacity. This limited displacement capacity can cause the reduction of the effective frequency of high frequency equipments and the increase of the inelastic energy absorption capacity due to the nonlinear behavior. In this study, the uniform hazard spectrum for Korean nuclear power plant site was modified using the response spectrum reduction factor developed by EPRI. The spectral acceleration for various damping ratio was determined by the theoretical method based on the random vibration theory. In conclusion, the high frequency components of evaluation response spectra were greatly reduced due to the consideration of welded anchorage ductility. This reduced response spectra can be used for the development of in-structure response spectra used in the seismic capacity evaluation of high frequency equipments

  3. 77 FR 60081 - Anchorages; Captain of the Port Puget Sound Zone, WA

    Science.gov (United States)

    2012-10-02

    ...'31'' W. Thorndike Bay Emergency Explosives Anchorage. Coordinates would be revised to read: All... 048[deg]T to point of origin. (6) Thorndike Bay Emergency Explosives Anchorage. All waters in a...

  4. Clinical application of micro-implant anchorage in initial orthodontic retraction.

    Science.gov (United States)

    Wahabuddin, Shaji; Mascarenhas, Rohan; Iqbal, Mahamad; Husain, Akhter

    2015-02-01

    Micro-implant is a device that is temporarily fixed to bone for the purpose of enhancing orthodontic anchorage either by supporting the teeth of the reactive unit or by obviating the need for the reactive unit altogether, and which is subsequently removed after use. The purpose of this study was to evaluate the clinical efficiency of micro-implants in reinforcing anchorage during the initial retraction of anterior teeth, check the rate of initial retraction for 8 weeks, and assess the stability of micro-implants during this period. Eighteen micro-implants were placed (10 in the maxilla and 8 in the mandible) and immediately loaded with 200-250 g of force using 9-mm closed coil Nitinol springs. The amount of space closure was measured every 2 weeks until the eighth week. Cephalometric measurements were made at the end of the study to evaluate anchor loss, if any. Micro-implant stability was also assessed. The rate of initial retraction in the maxilla at the end of 8 weeks was 1.65 mm/quadrant and 1.51 mm/quadrant in the mandible. The amount of retraction on the left side of the arches was 1.66 mm/quadrant and 1.49 mm/quadrant on the right side. The average initial retraction for both arches per month was 0.78 mm. An anchor loss of 0.1 mm (0.06%) was observed in the maxilla while no mandibular anchor loss was recorded. The rate of initial retraction observed in the maxilla was more than that achieved in the mandible. Initial retraction was also more on the left side of the arches. There was no anchor loss in the mandible. The micro-implant-reinforced anchorage was helpful in minimizing anchor loss and accepted heavy traction forces but did not bring about a faster rate of retraction.

  5. Water quality and bathymetry of Sand Lake, Anchorage, Alaska

    Science.gov (United States)

    Donaldson, Donald E.

    1976-01-01

    Sand Lake, a dimictic lowland lake in Anchorage, Alaska, has recently become as urban lake. Analyses indicate that the lake is oligotrophic, having low dissolved solids and nutrient concentrations. Snowmelt runoff from an adjacent residential area, however, has a dissolved-solids concentration 10 times that of the main body of Sand Lake. Lead concentrations in the runoff exceed known values from other water in the ANchorage area, including water samples taken beneath landfills. The volume of the snowmelt runoff has not been measured. The data presented can be used as a baseline for water-resource management. (Woodard-USGS)

  6. Surgical management of fractured orthodontic mini- implant- a case report.

    Science.gov (United States)

    Desai, Manthan; Jain, Anoop; Sumra, Nida

    2015-01-01

    The idea of absolute anchorage has always been an elusive goal for clinicians. Orthodontic mini-implants or temporary anchorage devices allow tooth movements previously thought to be impossible or difficult. Although extensive literature exists on use of temporary anchorage devices, their failures have been hardly focused upon, especially implant fracture. The following case report describes successful management of fractured orthodontic mini-implant.

  7. 77 FR 43514 - Anchorage Regulations; Narragansett Bay and Rhode Island Sound, RI

    Science.gov (United States)

    2012-07-25

    ...-AA01 Anchorage Regulations; Narragansett Bay and Rhode Island Sound, RI AGENCY: Coast Guard, DHS... Narragansett Bay, Rhode Island, and adding an offshore anchorage in Rhode Island Sound south of Brenton Point... rulemaking (NPRM) entitled ``Anchorage Regulations; Narragansett Bay and Rhode Island Sound, RI,'' in the...

  8. 25 CFR 11.607 - Temporary orders and temporary injunctions.

    Science.gov (United States)

    2010-04-01

    ... injunction: (1) Does not prejudice the rights of the parties or the child which are to be adjudicated at... temporary maintenance or temporary support of a child of the marriage entitled to support. The motion shall... the peace of the other party or of any child; (3) Excluding a party from the family home or from the...

  9. 78 FR 44917 - Anchorage Regulations; Port of New York

    Science.gov (United States)

    2013-07-25

    ...-AA01 Anchorage Regulations; Port of New York AGENCY: Coast Guard, DHS. ACTION: Notice of proposed... New York. This action is necessary to facilitate safe navigation and provide safe and secure... this rule, call or email Mr. Jeff Yunker, Sector New York, Waterways Management Division, U.S. Coast...

  10. 75 FR 22323 - Anchorage Regulations; Port of New York

    Science.gov (United States)

    2010-04-28

    ...-AA01 Anchorage Regulations; Port of New York AGENCY: Coast Guard, DHS. ACTION: Supplemental notice of..., Coast Guard Sector New York, Waterways Management Division; telephone 718-354-4195, e-mail Jeff.M.Yunker... Purpose The Hudson River Pilots Association, through the Port of New York/ New Jersey Harbor Safety...

  11. 76 FR 20524 - Anchorage Regulations; Port of New York

    Science.gov (United States)

    2011-04-13

    ...-AA01 Anchorage Regulations; Port of New York AGENCY: Coast Guard, DHS. ACTION: Final rule. SUMMARY: The... Yunker, Coast Guard Sector New York, Waterways Management Division; telephone 718-354-4195, e-mail Jeff.M... New York in the Federal Register (74 FR 47906). We received one comment on the NPRM. No public meeting...

  12. 75 FR 3641 - Television Broadcasting Services; Anchorage, AK

    Science.gov (United States)

    2010-01-22

    ... FEDERAL COMMUNICATIONS COMMISSION 47 CFR Part 73 [DA 10-40; MB Docket No. 09-210; RM-11583] Television Broadcasting Services; Anchorage, AK AGENCY: Federal Communications Commission. ACTION: Final rule... review Act, see 5 U.S.C. 801(a)(1)(A). List of Subjects in 47 CFR Part 73 Television, Television...

  13. Anchorage Behaviors of Frictional Tieback Anchors in Silty Sand

    Science.gov (United States)

    Hsu, Shih-Tsung; Hsiao, Wen-Ta; Chen, Ke-Ting; Hu, Wen-Chi; Wu, Ssu-Yi

    2017-06-01

    Soil anchors are extensively used in geotechnical applications, most commonly serve as tieback walls in deep excavations. To investigate the anchorage mechanisms of this tieback anchor, a constitutive model that considers both strain hardening and softening and volume dilatancy entitled SHASOVOD model, and FLAC3D software are used to perform 3-D numerical analyses. The results from field anchor tests are compared with those calculated by numerical analyses to enhance the applicability of the numerical method. After the calibration, this research carried out the parameter studies by numerical analyses. The numerical results reveal that whether the yield of soil around an anchor develops to ground surface and/or touches the diaphragm wall depending on the overburden depth H and the embedded depth Z of an anchor, this study suggests the minimum overburden and embedded depths to avoid the yield of soils develop to ground surface and/or touch the diaphragm wall. When the embedded depth, overburden depth or fixed length of an anchor increases, the anchorage capacity also increases. Increasing fixed length should be the optimum method to increase the anchorage capacity for fixed length less than 20m. However, when the fixed length of an anchor exceeds 30 m, the increasing rate of anchorage capacity per fixed length decreases, and progressive yield occurs obviously between the fixed length and surrounding soil.

  14. Magnesium alloys for temporary implant applications: stress corrosion cracking and biocompatible coating

    OpenAIRE

    Choudhary, Lokesh Kumar

    2017-01-01

    Magnesium (Mg) alloys have emerged as potential candidate materials for construction of biodegradable temporary implant devices particularly due to advantages of favourable mechanical properties, biodegradability and biocompatibility. However, the poor corrosion resistance of Mg alloys in the physiological environment presents a major challenge to their use as biodegradable temporary implants. Furthermore, complex interaction of mechanical loading and aggressive physiological environment may ...

  15. Temporary labour contracts

    CERN Document Server

    2000-01-01

    The five contracts for Temporary Labour assignments on the CERN site (L020/PE, L 021/PE, L 022/PE, L 023/PE and L 024/PE) approved by the Finance Committee in March 1996 (CERN/FC/3857) reached the end of their initial three-year contractual period at the end of December 1999. At CERN?s request, in September 1999 the Finance Committee approved an extension of these contracts for the year 2000 for a total amount not exceeding 6 000 000 Swiss francs (CERN/FC/4196). In December 1999, one of the five contractors, FIRCROFT, withdrew from its contract for 2000. Following the satisfactory execution of the four remaining contracts during 2000, CERN requests approval to extend them from January 2001 for the second of the two optional years provided for in the original adjudication. The Finance Committee is invited to approve the extension of the existing contracts until 31 December 2001 for a total amount not exceeding 6 000 000 Swiss francs at 2000 prices.

  16. K.S. Micro‑Implant Placement Guide

    African Journals Online (AJOL)

    after being injured by temporary orthodontic anchorage devices,[3] ... and does not disturb the existing appliance system, clearly ... The wire guide is fabricated using round 0.018 or 0.020 ... their clinical efficiency in anchorage control.

  17. A new non-metallic anchorage system for post-tensioning applications using CFRP tendons

    Science.gov (United States)

    Taha, Mahmoud Reda

    The objective of the work described in this thesis is to design, develop and test a new non-metallic anchorage system for post-tensioning applications using CFRP tendons. The use of a non-metallic anchorage system should eliminate corrosion and deterioration concerns in the anchorage zone. The development of a reliable non-metallic anchorage would provide an important contribution to this field of knowledge. The idea of the new anchorage is to hold the tendon through mechanical gripping. The anchorage consists of a barrel with a conical housing and four wedges. The anchorage components are made of ultra high performance concrete (UHPC) specially developed for the anchorage. Sixteen concrete mixtures with different casting and curing regimes were examined to develop four UHPC mixtures with compressive strengths in excess of 200 MPa. The UHPC mixtures showed very dense microstructures with some unique characteristics. To enhance the fracture toughness of the newly developed UHPC, analytical and experimental analyses were performed. Using 3 mm chopped carbon fibres, a significant increase in the fracture toughness of UHPC was achieved. The non-metallic anchorage was developed with the UHPC with enhanced fracture toughness. The barrel required careful wrapping with CFRP sheets to provide the confinement required to utilize the strength and toughness of the UHPC. Thirty-three anchorages were tested under both static and dynamic loading conditions. The non-metallic anchorage showed excellent mechanical performance and fulfilled the different requirements of a post-tensioning anchorage system. The development of the new non-metallic anchorage will widen the inclusion of CFRP tendons in post-tensioned concrete/masonry structures. The new system will offer the opportunity to exploit CFRP tendons effectively creating an innovative generation of corrosion-free, smart structures.

  18. The temporary international collective chronicle

    International Nuclear Information System (INIS)

    Kravchenko, Yu.Ya.

    2007-01-01

    The temporary international collective brief history is presented from the time of its establishment in 1972 (and even earlier) till the termination of its activity in 1990 (and even later). Works in the temporary international collective framework demonstrate an example of successful cooperation of specialists from different countries in the field of calculation-theoretical and experimental research on the WWER reactor physics. The results of experimental and calculation studies were reported to the topical meetings, workshops, conferences, and symposia as well as were published in the temporary international collective reports and proceedings. The answers to the questions about the temporary international collective activity-What? Where? When?-are presented in this chronicle (Authors)

  19. Temporary storage area characterization report

    International Nuclear Information System (INIS)

    1990-01-01

    The preferred alternative identified in the Remedial Investigation/Feasibility Study (RI/FS) for the Weldon Spring Quarry Bulk Wastes is to remove the wastes from the quarry and transport them by truck to temporary storage facility at the chemical plant site. To support the RI/FS, this report provides data to characterize the temporary storage area (TSA) site and to ensure the suitability of the proposed location. 31 refs., 14 figs., 7 tabs

  20. 5 CFR 213.3199 - Temporary organizations.

    Science.gov (United States)

    2010-01-01

    ... 5 Administrative Personnel 1 2010-01-01 2010-01-01 false Temporary organizations. 213.3199 Section... SERVICE Excepted Schedules Schedule A § 213.3199 Temporary organizations. Positions on the staffs of temporary organizations, as defined in 5 U.S.C. 3161(a). Appointments may not exceed 3 years, but temporary...

  1. 42 CFR 488.415 - Temporary management.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Temporary management. 488.415 Section 488.415... Compliance for Long-Term Care Facilities with Deficiencies § 488.415 Temporary management. (a) Definition. Temporary management means the temporary appointment by CMS or the State of a substitute facility manager or...

  2. Mash evaluation of TxDOT high-mounting-height temporary work zone sign support system.

    Science.gov (United States)

    2017-02-01

    The objective of this research was to develop a nonproprietary, lightweight, crashworthy, temporary work-zone single sign support for use with an aluminum sign substrate. The device is intended to meet the evaluation criteria in American Association ...

  3. Research on the Bond Anchorage Properties of Alkali-Activated Slag Cementitious Material

    Science.gov (United States)

    Zhu, J.; Zheng, W. Z.; Leng, Y. F.; Qin, C. Z.; Xu, Z. Z.

    2017-12-01

    By bond-anchorage property tests at 20°C ∼500°C, the distribution of shear stress between carbon fiber sheets and concrete at all levels of loading and anchorage lengths were measured, which means the bond lengths during CFRP sheets are pulled off at the same time when the concrete is torn and stripped were gotten. The failure modes were obtained. In addition, the failure loads were measured, and the calculated formulas of anchorage lengths were identified by fitting at high temperature. It can be seen that the anchorage lengths of carbon fiber sheets increase with increasing temperature at 20°C ∼100°C, the anchorage lengths of carbon fiber sheets decrease with increasing temperature at 100°C ∼500°C. Tests prove that AASCM has favorable high-temperature resistant and bond anchorage properties.

  4. Research on Anchorage Performance of Grouting Anchor Connection of Precast Concrete Structure

    Science.gov (United States)

    Wang, Donghui; Liu, Xudong; Wang, Sheng; Cao, Xixi

    2018-03-01

    The bonding of grouted anchor bars is one of the vertical connection forms of steel bars in fabricated concrete structures. The performance of grouted connection is mainly affected by the anchorage length and lap length of steel bars. The mechanisms of bond and anchorage between steel bar and concrete are analyzed, and the factors that influence the anchorage performance of steel bar are systematically summarized. Results show that the bond and anchorage performance of steel and concrete have been studied widely, but there are still shortcomings, and the connection forms need to be further improved.

  5. Efficacy of the Nance appliance as an anchorage-reinforcement method.

    Science.gov (United States)

    Al-Awadhi, Ebrahim A; Garvey, Therese M; Alhag, Mohamed; Claffey, Noel M; O'Connell, Brian

    2015-03-01

    The Nance appliance is widely considered to be an efficient method of anchorage reinforcement; however, much of the perceived advantage is based on clinical judgment. The aim of this study was to assess the amounts of anchorage loss and desired tooth movement associated with the Nance appliance. The mandibular arches of 7 beagle dogs were used. The first and third premolars were extracted. Reference miniscrews were placed at the first premolar sites as stable references to measure the amounts of anchorage loss and desired tooth movement. Four beagles were fitted with custom-made Nance appliances on the fourth premolars and orthodontic bands on the second premolars (Nance group). Three beagles were fitted with orthodontic bands on the second and fourth premolars with no anchorage reinforcement (control group). The second premolars were retracted over 15 weeks in both groups. The amounts of second premolar movement (desired tooth movement) and fourth premolar movement (anchorage loss) were recorded at 5, 10, and 15 weeks. The percentages of desired tooth movement and anchorage loss to the total space closure were calculated. The mean desired tooth movement was significantly more in the Nance group than in the control group at 10 weeks (P appliance did not provide absolute anchorage, but there was significantly less anchorage loss with it than in the control group. The majority of anchorage loss occurred during the first 10 weeks in the Nance group. Copyright © 2015 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  6. A temporary index

    International Nuclear Information System (INIS)

    Thomson, Jon; Craighead, Alison

    2015-01-01

    The ongoing management of low, intermediate and high-level nuclear waste is an unresolved issue for humanity, not least because the time-frames in question when dealing with the hazards of radioactive wastes, range from as little as a few tens of years to more than 100 000 years. It is from this starting point that we are beginning the development of an ambitious multifaceted artwork aiming to help us consider our relationship with deep-time and our nuclear legacy. The expressed aim of Temporary Index is to raise general awareness about these long-term management issues, and in doing so, to embed this knowledge into our collective cultural memory so as to transmit useful information about our nuclear waste into the future. We wish to create a series of decorative, real-time numeric counters based on the probabilistic decay (including decay of daughter products) of existing nuclear waste that we identify from the earliest weapons' development programmes in the United States right through to contemporary wastes being produced by nuclear energy production today across the world. Each display will countdown in seconds, showing the time remaining before the given item of waste (or a particular site) is considered safe to humans. A hypothetical example of one counter could be a bottle of sludge containing plutonium discovered in 2004 during an attempted clean-up of the Hanford nuclear site in Washington State, United States. Another example might be the geological storage facility for vitrified nuclear waste at Horonobe in Japan, should it be established in the future. Accident sites, such as Chernobyl or Fukushima Daiichi could also be tagged with counters, as could low-level waste (LLW) repositories such as the one at Drigg near Sellafield in the United Kingdom. Whatever the items identified and this will be a complex process requiring collaboration with experts in the field, it is important that a wide range of short- and long-term counters are established to

  7. Local application of zoledronate for maximum anchorage during space closure.

    Science.gov (United States)

    Ortega, Adam J A J; Campbell, Phillip M; Hinton, Robert; Naidu, Aparna; Buschang, Peter H

    2012-12-01

    Orthodontists have used various compliance-dependent physical means such as headgears and intraoral appliances to prevent anchorage loss. The aim of this study was to determine whether 1 local application of the bisphosphonate zoledronate could be used to prevent anchorage loss during extraction space closure in rats. Thirty rats had their maxillary left first molars extracted and their maxillary left second molars protracted into the extraction space with a 10-g nickel-titanium closing coil for 21 days. Fifteen control rats received a local injection of phosphate-buffered saline solution, and 15 experimental rats received 16 μg of the bisphosphonate zoledronate. Bisphosphonate was also delivered directly into the extraction site and left undisturbed for 5 minutes. Cephalograms and incremental thickness gauges were used to measure tooth movements. Tissues were analyzed by microcomputed tomography and histology. The control group demonstrated significant (P <0.05) tooth movements throughout the 21-day period. They showed significantly greater tooth movements than the experimental group beginning in the second week. The experimental group showed no significant tooth movement after the first week. The microcomputed tomography and histologic observations showed significant bone loss in the extraction sites and around the second molars of the controls. In contrast, the experimental group had bone preservation and bone fill. There was no evidence of bisphosphonate-associated osteonecrosis in any sample. A single small, locally applied dose of zoledronate provided maximum anchorage and prevented significant bone loss. Copyright © 2012 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  8. Comparative photoelastic study of dental and skeletal anchorages in the canine retraction

    Directory of Open Access Journals (Sweden)

    Cristiane Aparecida de Assis Claro

    2014-01-01

    Full Text Available OBJECTIVE: To compare dental and skeletal anchorages in mandibular canine retraction by means of a stress distribution analysis. METHODS: A photoelastic model was produced from second molar to canine, without the first premolar, and mandibular canine retraction was simulated by a rubber band tied to two types of anchorage: dental anchorage, in the first molar attached to adjacent teeth, and skeletal anchorage with a hook simulating the mini-implant. The forces were applied 10 times and observed in a circular polariscope. The stresses located in the mandibular canine were recorded in 7 regions. The Mann-Whitney test was employed to compare the stress in each region and between both anchorage systems. The stresses in the mandibular canine periradicular regions were compared by the Kruskal-Wallis test. RESULTS: Stresses were similar in the cervical region and the middle third. In the apical third, the stresses associated with skeletal anchorage were higher than the stresses associated with dental anchorage. The results of the Kruskal-Wallis test showed that the highest stresses were identified in the cervical-distal, apical-distal, and apex regions with the use of dental anchorage, and in the apical-distal, apical-mesial, cervical-distal, and apex regions with the use of skeletal anchorage. CONCLUSIONS: The use of skeletal anchorage in canine retraction caused greater stress in the apical third than the use of dental anchorage, which indicates an intrusive component resulting from the direction of the force due to the position of the mini-implant and the bracket hook of the canine.

  9. Temporary tattoo for wireless human pulse measurement

    Science.gov (United States)

    Pepłowski, Andrzej; Janczak, Daniel; Krzemińska, Patrycja; Jakubowska, Małgorzata

    2016-09-01

    Screen-printed sensor for measuring human pulse was designed and first tests using a demonstrator device were conducted. Various materials and sensors' set ups were compared and the results are presented as the starting point for fabrication of fully functional device. As a screen printing substrate, commercially available temporary tattoo paper was used. Using previously developed nanomaterials-based pastes design of a pressure sensor was printed on the paper and attached to the epidermis. Measurements were aimed at determining sensors impedance constant component and its variability due to pressure wave caused by the human pulse. The constant component was ranging from 2kΩ to 6kΩ and the variations of the impedance were ranging from +/-200Ω to +/-2.5kΩ, depending on the materials used and the sensor's configuration. Calculated signal-to-noise ratio was 3.56:1 for the configuration yielding the highest signal level. As the device's net impedance influences the effectiveness of the wireless communication, the results presented allow for proper design of the sensor for future health-monitoring devices.

  10. Orthodontic space closure after first molar extraction without skeletal anchorage.

    Science.gov (United States)

    Jacobs, Collin; Jacobs-Müller, Claudia; Luley, Carolin; Erbe, Christina; Wehrbein, Heiner

    2011-03-01

    The aim of the study was an analysis of effects and side-effects during mesialization of second molars after extraction of the first permanent molars using the anterior dentition/premolars (PM) as an anchorage unit. A total of 35 patients were examined retrospectively who had undergone unilateral or bilateral first permanent molar extraction in the upper or lower arch due to carious lesions. Space closure was carried out in all cases through mesialization of the second molar using an elastic chain fixed to an edgewise stainless steel archwire and tying the anterior dentition/PM together with a continuous laceback ligature. Tooth movement was assessed from lateral cephalograms, orthopantomograms (OPGs) and images of the patient's study casts taken before and after the end of therapy. Space closure after first molar extractions by mesialization of the second molars without skeletal anchorage was largely achieved by bodily forward movement of the teeth, including a small tipping component or tooth-uprighting component when molars were already mesially inclined. Unilateral and bilateral mesialization of the second molars led to retrusion in the maxilla and mandible [(∆incl.=-3.6° (max., bil.), ∆incl.=-4.2° (mand., bil.)] and to translational retraction [(∆s=-2.3 mm (max., bil.), ∆s=-1.6 mm (mand., bil.)] of the incisors. Examination of the soft tissues revealed an increased posterior displacement of the upper and lower lips to the esthetic line [(∆s=-2.8 mm (max. bil.), ∆s=-2.2 mm (mand., bil.)]. In cases of unilateral mesialization less than 50% of the patients had a slight midline deviation in the mandible towards the extraction side. Side effects during mesialization of the second molars without skeletal anchorage in the anterior dentition/PM were observed primarily affecting the incisors integrated into the anterior anchorage unit. These side-effects resulted in posterior displacement of the soft tissues, including a change in profile. This must be

  11. Testing of large prestressing tendon end anchorage regions

    International Nuclear Information System (INIS)

    Johnson, T.E.

    1976-01-01

    Tests were performed on concrete end anchorage regions for prestressing tendons with ultimate strengths of approximately 8,900 kN. One test structure simulated a full scale concrete containment buttress and the other two test specimens were concrete blocks. The behavior of the test structure and specimens, when subjected to loading, was monitored by strain gages and dial gages. The testing illustrated that all of the amounts of reinforcing tested should be acceptable for the end anchor zones of large tendons presently used in prestressed concrete containment structures. (author)

  12. Connecting Temporary and Permanent Organizing

    DEFF Research Database (Denmark)

    Stjerne, Iben Sandal; Velikova, Silviya Svejenova

    2016-01-01

    This paper investigates the relationship between a permanent organization and a series of temporary organizations. It draws on an in-depth study of the process through which a Danish film production company, seeking to balance innovation and persistence in a troubled industry, struggles to realize...... a novel children’s film and its sequels. The study reveals tensions at different levels as well as boundary work and boundary roles that address them, bringing in shadows of past and future projects. The study extends the understanding of the dialectic between temporary and permanent organizing...

  13. Evaluating the effects of consolidation on intrusion and retraction using temporary anchorage devices—a FEM study

    Directory of Open Access Journals (Sweden)

    Monica Namburi

    2017-01-01

    Full Text Available Abstract Background Extraction of premolars and retracting the anterior teeth using mini-implants and anterior retraction hooks became advent now a day. In such treatments, consolidation of arches is not done in regular practice. So, the present study is concentrated on effects of consolidation in two implant and three implant combinations of retraction and intrusion. Methods A three-dimensional FEM model of maxillary teeth and periodontal ligament housed in the alveolar bone with the first premolars extracted is generated with appropriate number of elements and nodes. The models were broadly divided into two groups according to the no. of implants. Mini-implants were placed bilaterally between the second premolar and molar at varying heights (7, 10, 13 mm in group I, and along with bilateral implants, an additional mid-implant is placed between the central incisors as group II. Brackets with 0.022 slot were placed on the teeth, 19 × 25 SS wire is placed in the brackets, an anterior retraction hook was placed at 9 mm height, and analysis was done to evaluate the stresses and displacement patterns in consolidation and non-consolidation models. Results The results showed that consolidation of the anterior teeth during intrusion and retraction shows various advantages such as less stresses on the bone, PDL, implant, teeth, and no labial flaring of the anterior teeth and three implant system, i.e., two bilateral implant at 10 mm and a mid-implant at 12 mm between the centrals has shown to be better than other models as bodily movement is observed. Conclusion Consolidation is better than non consolidation during enmasse retraction and intrusion.

  14. 33 CFR 162.136 - Connecting waters from Lake Huron to Lake Erie; anchorage grounds.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Connecting waters from Lake Huron to Lake Erie; anchorage grounds. 162.136 Section 162.136 Navigation and Navigable Waters COAST GUARD... REGULATIONS § 162.136 Connecting waters from Lake Huron to Lake Erie; anchorage grounds. (a) In the Detroit...

  15. 76 FR 15246 - Anchorage Regulations; Narragansett Bay and Rhode Island Sound, RI

    Science.gov (United States)

    2011-03-21

    ...-AA01 Anchorage Regulations; Narragansett Bay and Rhode Island Sound, RI AGENCY: Coast Guard, DHS... Rhode Island Sound south of Brenton Point, Rhode Island, for use by vessels waiting to enter... Sound that under current informal practice is routinely used by mariners as an anchorage while waiting...

  16. Numerical Simulation and Experimental Validation of an Integrated Sleeve-Wedge Anchorage for CFRP Rods

    DEFF Research Database (Denmark)

    Schmidt, Jacob Wittrup; Smith, Scott T.; Täljsten, Björn

    2011-01-01

    . Recently, an integrated sleeve-wedge anchorage has been successfully developed specifically for CFRP rods. This paper in turn presents a numerical simulation of the newly developed anchorage using ABAQUS. The three-dimensional finite element (FE) model, which considers material non-linearity, uses...

  17. 33 CFR 166.200 - Shipping safety fairways and anchorage areas, Gulf of Mexico.

    Science.gov (United States)

    2010-07-01

    ... anchorage areas, Gulf of Mexico. 166.200 Section 166.200 Navigation and Navigable Waters COAST GUARD... the erection of structures therein to provide safe approaches through oil fields in the Gulf of Mexico... for Fairway Anchorages in the Gulf of Mexico. Structures may be placed within an area designated as a...

  18. Flexural Strengthening of RC Slabs with Prestressed CFRP Strips Using Different Anchorage Systems

    Directory of Open Access Journals (Sweden)

    José Sena-Cruz

    2015-10-01

    Full Text Available Externally Bonded Reinforcement (EBR technique has been widely used for flexural strengthening of concrete structures by using carbon fiber-reinforced polymers (CFRP. EBR technique offers several structural advantages when the CFRP material is prestressed. This paper presents an experimental and numerical study on reinforced (RC slabs strengthened in flexure with prestressed CFRP strips as a structural strengthening system. The strips are applied as an externally bonded reinforcement (EBR and anchored with either a mechanical or a gradient anchorage. The former foresees metallic anchorage plates fixed to the concrete substrate, while the latter is based on an accelerated epoxy resin curing followed by a segment-wise prestress force decrease at the strip ends. Both anchorage systems, in combination with different CFRP strip geometries, were subjected to static loading tests. It could be demonstrated that the composite strip’s performance is better exploited when prestressing is used, with slightly higher overall load carrying capacities for mechanical anchorages than for the gradient anchorage. The performed investigations by means of a cross-section analysis supported the experimental observation that in case a mechanical anchorage is used, progressive strip debonding changes the fully bonded configuration to an unbonded end-anchored system. The inclusion of defined debonding criteria for both the anchorage zones and free length between the anchorage regions allowed to precisely capture the ultimate loading forces.

  19. Morbidity of temporary loop ileostomies

    NARCIS (Netherlands)

    Bakx, R.; Busch, O. R. C.; Bemelman, W. A.; Veldink, G. J.; Slors, J. F. M.; van Lanschot, J. J. B.

    2004-01-01

    Background/Aims: A temporary loop ileostomy is constructed to protect a distal colonic anastomosis. Closure is usually performed not earlier than 8 - 12 weeks after the primary operation. During this period, stoma-related complications can occur and enhance the adverse effect on quality of life. The

  20. Temporary employment and health: a review.

    Science.gov (United States)

    Virtanen, Marianna; Kivimäki, Mika; Joensuu, Matti; Virtanen, Pekka; Elovainio, Marko; Vahtera, Jussi

    2005-06-01

    We aimed to review evidence on the relationship between temporary employment and health, and to see whether the association is dependent on outcome measure, instability of employment, and contextual factors. We systematically searched for studies of temporary employment and various health outcomes and critically appraised 27 studies. The review suggests higher psychological morbidity among temporary workers compared with permanent employees. According to some studies, temporary workers also have a higher risk of occupational injuries but their sickness absence is lower. Morbidity may be higher in temporary jobs with high employment instability and in countries with a lower number of temporary workers and unemployed workers. The evidence indicates an association between temporary employment and psychological morbidity. The health risk may depend on instability of temporary employment and the context. Confounding by occupation may have biased some of the studies. Additional research to clarify the role of employment instability, hazard accumulation, and selection is recommended.

  1. Employment protection and temporary work agencies

    OpenAIRE

    Baumann, Florian; Mechtel, Mario; Stähler, Nikolai

    2008-01-01

    Employers who use temporary agency staff in contrast to regular staff are not affected by employment protection regulations when terminating a job. Therefore, services provided by temporary work agencies may be seen as a substitute for regular employment. In this paper, we analyze the effects of employment protection on the size of the temporary work agency sector in a model of equilibrium unemployment. We find that higher firing costs may even reduce temporary work agency employment if agenc...

  2. Mini-placa como ancoragem ortodôntica: relato de caso Mini screw as orthodontic anchorage: case report

    Directory of Open Access Journals (Sweden)

    André Luiz Zétola

    2005-08-01

    ígida pode ser utilizada com bastante propriedade no tratamento ortodôntico qunado for requerida uma ancoragem máxima.It is needless to say that anchorage control is necessary to a successful orthodontic treatment. Without it, it would be impossible to obtain an ideal occlusion through orthodontic mechanics in the majority of cases. The utilization of rigid devices, originated from face traumatology and implant dentistry principles, to obtain rigid anchorage in orthodontics revolutionized the way of treating cases with an unsatisfactory prognosis. Specially in cases where a lot of anchorage is needed and it is difficult or impossible to get it. The objective of this article was to revise the literature related to the use of mini-screw implant systems, to report a case where it was utilized and to discuss some aspects related to the usage of rigid anchorage orthodontics. The rigid anchorage was used in a 39 year old female patient, who had the upper left molars with a relevant extrusion due to the absence of the lower left molars. Fixed appliances were placed on the upper arch with a TPA connecting the second bicuspids. The TPA was used to anchor the intrusion of the upper left molars. A quad-helix appliance was used to correct the upper right third molar crossbite. Since the orthodontic intrusion with only dental anchorage did not have a satisfactory result, an "L" shaped titanium plate was placed on the maxilla, at the apical region of the upper first and second left molars, with the purpose of obtaining a rigid orthodontic anchorage to intrude them. Elastics were used during five months with intrusive force,the obtained intrusion was 6 millimeters. After the removal of the appliance, upper and lower dental bleaching was made and final prosthesis were placed over the implants. Through the literature reviewed and the case reported, it can be concluded that rigid anchorage can be indicated in orthodontic treatments where there is lack of anchorage or the need of an absolute

  3. 36 CFR 13.182 - Temporary facilities.

    Science.gov (United States)

    2010-07-01

    ... 36 Parks, Forests, and Public Property 1 2010-07-01 2010-07-01 false Temporary facilities. 13.182... NATIONAL PARK SYSTEM UNITS IN ALASKA Cabins Use of Temporary Facilities Related to Taking Fish and Wildlife § 13.182 Temporary facilities. In a national preserve where the taking of fish and wildlife is...

  4. Temporary Clusters and Knowledge Creation

    DEFF Research Database (Denmark)

    Maskell, Peter; Bathelt, Harald; Malmberg, Anders

    2004-01-01

    or participating in such events are means toidentify the current market frontier, take stock of relative competitive positions and formfuture plans. These events exhibit many of the characteristics ascribed to permanentclusters, albeit in a temporary, periodic and intensified form. The temporary clusters...... arehotspots of intense knowledge exchange, network building and idea generation.In investigating the extent and nature of these phenomena, the present paper explores anumber of issues. First, it shows that international trade fairs and other professionalgatherings are events which enable firms to compare...... their own products with others whichare available to the world market. Comparisons to and interactions with other firmsstimulate processes of knowledge creation. Second, it demonstrates how trade fairs areimportant for firms when selecting partners with whom to develop global pipelines,enabling access...

  5. Temporary Residences: a becoming project

    Directory of Open Access Journals (Sweden)

    Luisa Ingaramo

    2012-04-01

    Full Text Available Among the experimental actions fostered so far by the Compagnia di San Paolo through its Housing Program, committed in handling the complex and fragmented housing discomfort issue, the Temporary Dwellings initiative represents a unique and innovative experience, as it actually offers the chance to activate a proper managerial direction around and about the real estate development processes. In particular, the Temporary Dwellings action is marked by two key aspects: a structured co-planning vision and projects selected through a requests for proposal system. The process in the whole aims on the one hand at reaching an high transparent level of decision making , while, on the other hand, at developing a continuous and mutual monitoring and matching activity between the Housing Program and the group of cross-curricular experts teamed up in the project: technicians, designers, managers, psychologists, contractors, and the other local stakeholders.

  6. Large capacity temporary visual memory

    Science.gov (United States)

    Endress, Ansgar D.; Potter, Mary C.

    2014-01-01

    Visual working memory (WM) capacity is thought to be limited to three or four items. However, many cognitive activities seem to require larger temporary memory stores. Here, we provide evidence for a temporary memory store with much larger capacity than past WM capacity estimates. Further, based on previous WM research, we show that a single factor — proactive interference — is sufficient to bring capacity estimates down to the range of previous WM capacity estimates. Participants saw a rapid serial visual presentation (RSVP) of 5 to 21 pictures of familiar objects or words presented at rates of 4/s or 8/s, respectively, and thus too fast for strategies such as rehearsal. Recognition memory was tested with a single probe item. When new items were used on all trials, no fixed memory capacities were observed, with estimates of up to 9.1 retained pictures for 21-item lists, and up to 30.0 retained pictures for 100-item lists, and no clear upper bound to how many items could be retained. Further, memory items were not stored in a temporally stable form of memory, but decayed almost completely after a few minutes. In contrast, when, as in most WM experiments, a small set of items was reused across all trials, thus creating proactive interference among items, capacity remained in the range reported in previous WM experiments. These results show that humans have a large-capacity temporary memory store in the absence of proactive interference, and raise the question of whether temporary memory in everyday cognitive processing is severely limited as in WM experiments, or has the much larger capacity found in the present experiments. PMID:23937181

  7. Transcending Organization in Temporary Systems

    DEFF Research Database (Denmark)

    Stjerne, Iben Sandal

    in temporary systems that lack stability and formal order. It advances our understanding of transcending organization in creative industries by adopting a practice based perspective. Empirically, the dissertation presents an in-depth study of the Danish film industry, which is an extreme case of a project...... film workers with different functional roles and six months of ethnographic study of film projects in the Danish film industry, in particular delving into the film project Antboy and its sequels....

  8. Mechanical anchorage of FRP tendons – A literature review

    DEFF Research Database (Denmark)

    Schmidt, Jacob W.; Bennitz, Anders; Täljsten, Björn

    2012-01-01

    High tensile strength, good resistance to degradation and creep, low weight and, to some extent, the ability to change the modulus of elasticity are some of the advantages of using prestressed, unidirectional FRP (Fibre Reinforced Polymer) tendon systems. Bonded and non-bonded versions of these s......High tensile strength, good resistance to degradation and creep, low weight and, to some extent, the ability to change the modulus of elasticity are some of the advantages of using prestressed, unidirectional FRP (Fibre Reinforced Polymer) tendon systems. Bonded and non-bonded versions...... with such systems. This is especially important in external post-tensioned tendon systems, where the anchorage points are exposed to the full load throughout the life span of the structure. Consequently, there are large requirements related to the long-term capacity and fatigue resistance of such systems. Several...

  9. Temporary air-raid shelters

    International Nuclear Information System (INIS)

    Jokela, J.; Olin, J.; Koukkari, H.

    1983-05-01

    This report deals with materials and structures of temporary air-raid shelters. At first, the weapon effects against which the temporary shelters can protect are described. These are, primarily, the fragmentation and blast pressure caused by conventional weapons and those effects of the nuclear weapons which exist outside the total disaster and fire areas. Temporary shelters built into existing buildings can give protection either from radioactive fallout or from fallout and collapse of the building above. For fallout protection heavy materials are needed, which simultaneously protect from fragmentation. In the research report, the methods and materials used for the contruction of a fallout shelter into an apartment house and a small house are introduced. The collapse loads acting on a basement ceiling and the design of additional timber supports are also presented. The use of various materials in the construction of shelters outside the buildings are introduced. Separate shelters can be built either under the ground or on the ground. The same materials can be used in both cases, but the underground shelters have a better level of protection. (author)

  10. Factors predisposing to maxillary anchorage loss: a retrospective study of 1403 cases.

    Directory of Open Access Journals (Sweden)

    Hong Su

    Full Text Available Anchorage loss is very disturbing for orthodontists and patients during orthodontic treatment, which usually results in bad treatment effects. Despite the same treatment strategy, different patients show different tendencies toward anchorage loss, which influences the treatment results and should preferably be predicted before the treatment is begun. However, relatively little research has been conducted on which patients are more likely to lose anchorage. The mesial tipping of the first molar marks the onset of anchorage loss, and changes in the angulation of the first molar are closely related to anchorage loss. This cross-sectional study aimed to determine how the mesiodistal angulation of the upper first molars changes during general orthodontic treatment and to identify the individual physiologic factors leading to these changes in a large sample of 1403 patients with malocclusion. The data indicate that the upper first molars tend to be tipped mesially during orthodontic treatment, and this constitutes a type of anchorage loss that orthodontists should consider carefully. Compared to treatment-related factors, patients' physiologic characteristics have a greater influence on changes in the angulation of the upper first molars during orthodontic treatment. The more distally tipped the upper first molars are before treatment, the more they will tip mesially during treatment. Mesial tipping of the upper first molars, and therefore, anchorage loss, is more likely to occur in adolescents, males, patients with class II malocclusion and patients who have undergone maxillary premolar extraction. This finding is of clinical significance to orthodontists who wish to prevent iatrogenic anchorage loss by tipping originally distally tipped upper molars forward, and provides a new perspective on anchorage during orthodontic treatment planning.

  11. Temporary stenting and retrieval of the self-expandable, intracranial stent in acute middle cerebral artery occlusion

    Energy Technology Data Exchange (ETDEWEB)

    Suh, Sang Hyun; Chung, Tae-Sub [Yonsei University College of Medicine, Department of Radiology, Gangnam Severance Hospital, Seoul (Korea); Lee, Kyung-Yul [Yonsei University College of Medicine, Department of Neurology, Gangnam Severance Hospital, Seoul (Korea); Hong, Chang Ki; Kim, Chang-Hyun [Yonsei University College of Medicine, Department of Neurosurgery, Gangnam Severance Hospital, Seoul (Korea); Kim, Byung Moon; Kim, Dong Ik [Yonsei University College of Medicine, Department of Radiology, Seoul (Korea)

    2009-08-15

    We describe our experience in which a retrievable Enterprise stent was used as a temporary recanalization and embolectomy device in an acute middle cerebral artery (MCA) occlusion after urgent stenting for ipsilateral carotid artery stenosis. (orig.)

  12. A novel anchorage technique for transnasal traction in rigid external maxillary distraction.

    Science.gov (United States)

    Varol, A; Basa, S

    2013-12-01

    We describe an effective technique for anchorage of transnasal traction in the management of maxillary rotation during external distraction. Copyright © 2012 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  13. Calculation of absorbed dose of anchorage-dependent cells from internal beta-rays irradiation

    International Nuclear Information System (INIS)

    Chen Jianwei; Huang Gang; Li Shijun

    2001-01-01

    Objective: To elicit the formula of internal dosimetry in anchorage-dependent cells by beta-emitting radionuclides from uniformly distributed volume sources. Methods: By means of the definition of absorbed dose and the MIRD (Medical International Radiation Dose) scheme the formula of internal dosimetry was reasonably deduced. Firstly, studying the systems of suspension culture cells. Then, taking account of the speciality of the systems of the anchorage-dependent cells and the directions of irradiation, the absorbed dose of anchorage -dependent cells was calculated by the accumulated radioactivity, beta-ray energy, and the volume of the cultured systems. Results: The formula of internal dosimetry of suspension culture cells and anchorage-dependent cells were achieved. At the same time, the formula of internal dosimetry of suspension culture cells was compared with that of MIRD and was confirmed accurate. Conclusion: The formula of internal dosimetry is concise, reliable and accurate

  14. [Clinical effects of micro-implant and traditional anchorage in orthodontic treatments].

    Science.gov (United States)

    Qian, Yi; Zhou, Hua-Jie; Wu, Jian-Hua

    2017-06-01

    To analyze the value of micro-implant and traditional anchorage in the treatment of malocclusion. From Jan 2015 to Jan 2016, 20 cases with malocclusion were randomly divided into control group(10) and experimental group (10). A comparison was conducted between the control group, in which traditional anchorage was used and the experimental group, in which micro-implant anchorage was adopted. The data were analyzed with SPSS 17.0 software package. There was significant difference of U1-NA, L1-NB, U1-APg, U6-PtPNS between the 2 groups(PMicro-implant anchorage can improve overjet relation of the anterior teeth and effect of orthodontic treatment.

  15. Liver Cell Culture Devices

    NARCIS (Netherlands)

    Andria, B.; Bracco, A.; Cirino, G.; Chamuleau, R. A. F. M.

    2010-01-01

    In the last 15 years many different liver cell culture devices, consisting of functional liver cells and artificial materials, have been developed. They have been devised for numerous different applications, such as temporary organ replacement (a bridge to liver transplantation or native liver

  16. Transfer and anchorage bond behaviour in self-compacting concrete

    Directory of Open Access Journals (Sweden)

    Rigueira-Víctor, J. W.

    2006-12-01

    Full Text Available Self-compacting concretes (SCC provide solutions to the problems facing precast concrete construction, enhancing competitiveness, reducing turnaround times and improving final product quality. SCC is fast becoming a key product for the future development of the precast pre-stressed concrete industry.The present paper compares the bond performance of SCC and traditional concrete (TC. The bond performance results confirm the viability of SCC in precast pre-stressed concrete manufacture, despite a slightly higher loss of pre-stressing force and slightly greater anchorage lengths in SCC with a low water/cement ratio. No differences in transfer or anchorage length were detected,however, when high strength TC and SCC were compared. The ECADA test method proved to be well suited to detecting the differences between the concretes analyzed.El desarrollo de los hormigones autocompactantes (SCCofrece muchas posibilidades a las construcciones con hormigón prefabricado, aumentando su competitividad, reduciéndolos plazos de fabricación y ofreciendo mejoras en la calidad del producto final. El SCC se está convirtiendo en un producto clave para el futuro desarrollo de la industria de prefabricados de hormigón pretensado.En este estudio se compara el comportamiento adherente de los SCC con el de los hormigones tradicionales (TC actuales. Los resultados obtenidos confirman la viabilidad del uso de los SCC para la fabricación de elementos prefabricados con hormigón pretensado, en lo relativo a su comportamiento adherente, aunque con la necesidad de considerar unas pérdidas de pretensado ligeramente mayores. Asimismo,debe esperarse un ligero aumento de las longitudes de anclaje cuando se trabaje con SCC de baja relación agua/cemento. Sin embargo, no se han detectado diferencias de comportamiento entre ambos tipos de hormigón cuando la resistencia a compresión es alta en lo relativo a las longitudes de transmisión y anclaje. El método de ensayo ECADA

  17. Temporary employment in Russia: why mostly men?

    Directory of Open Access Journals (Sweden)

    Tatiana Karabchuk

    2012-08-01

    Full Text Available The paper deals with temporary employment in the Russian labour market. The main focus is the gender difference regarding determinants of temporary employment. Unlike most European countries, where women are more likely to have temporary work, in Russia men predominantly have this status, comparable to the situation in many developing countries. This paper seeks to understand why this is the case. The household survey of NOBUS (held in 2003 by State Statistical Centre with World Bank participation is used to answer this question: the results suggest that gender differences in temporary employment do exist, and that the main factors that explain these differences are education, and marital status.

  18. Isolated scaphotrapeziotrapezoid osteoarthritis treatment using resurfacing arthroplasty with scaphoid anchorage.

    Science.gov (United States)

    Humada Álvarez, G; Simón Pérez, C; García Medrano, B; Faour Martín, O; Marcos Rodríguez, J J; Vega Castrillo, A; Martín Ferrero, M A

    The aim of this study is to show the results of scaphotrapeziotrapezoid (STT) joint osteoarthritis treatment performing resurfacing arthroplasty with scaphoid anchorage. An observational, descriptive and retrospective study was performed. Ten patients with isolated STT joint osteoarthritis were studied between 2013 and 2015. The mean follow-up time was 26months. Clinical results, functional and subjective scores were reviewed. The patients were satisfied, achieving an average of 2.1 (0-3) on the VAS score and 16 (2 to 28) in the DASH questionnaire, and returning to work in the first three months post-surgery. Recovery of range of motion compared to the contralateral wrist was 96% in extension, 95% in flexion, 87% in ulnar deviation and 91% in radial deviation. The average handgrip strength of the wrist was 95% and pinch strength was 95% compared to the contralateral side. There were no intraoperative complications or alterations in postoperative carpal alignment. Resurfacing arthroplasty is proposed as a good and novel alternative in treating isolated SST joint arthritis. Achieving the correct balance between the strength and mobility of the wrist, without causing carpal destabilisation, is important to obtain satisfactory clinical and functional results. Copyright © 2017. Publicado por Elsevier España, S.L.U.

  19. Ultraconformable Temporary Tattoo Electrodes for Electrophysiology

    Science.gov (United States)

    Ferrari, Laura M.; Sudha, Sudha; Tarantino, Sergio; Esposti, Roberto; Bolzoni, Francesco; Cavallari, Paolo; Cipriani, Christian

    2018-01-01

    Abstract Electrically interfacing the skin for monitoring personal health condition is the basis of skin‐contact electrophysiology. In the clinical practice the use of stiff and bulky pregelled or dry electrodes, in contrast to the soft body tissues, imposes severe restrictions to user comfort and mobility while limiting clinical applications. Here, in this work dry, unperceivable temporary tattoo electrodes are presented. Customized single or multielectrode arrays are readily fabricated by inkjet printing of conducting polymer onto commercial decal transfer paper, which allows for easy transfer on the user's skin. Conformal adhesion to the skin is provided thanks to their ultralow thickness (Tattoo electrode–skin contact impedance is characterized on short‐ (1 h) and long‐term (48 h) and compared with standard pregelled and dry electrodes. The viability in electrophysiology is validated by surface electromyography and electrocardiography recordings on various locations on limbs and face. A novel concept of tattoo as perforable skin‐contact electrode, through which hairs can grow, is demonstrated, thus permitting to envision very long‐term recordings on areas with high hair density. The proposed materials and patterning strategy make this technology amenable for large‐scale production of low‐cost sensing devices. PMID:29593975

  20. Diversity patterns of temporary wetland macroinvertebrate ...

    African Journals Online (AJOL)

    Although macroinvertebrates are potentially useful for assessing the condition of temporary wetlands, little is yet known about them. Macroinvertebrate assemblages were assessed in 138 temporary wetlands in the south-western Cape, recording 126 taxa. However, predicted richness estimates were all higher than the ...

  1. Lessons learnt from experimental temporary octopus fishing ...

    African Journals Online (AJOL)

    This paper presents evidence of the fisheries effect of experimental temporary fishing closures for Octopus in the then-emergent Velondriake Locally Managed Marine Area (LMMA) in south-west Madagascar during 2004–2006. We present an analysis of the O. cyanea catch data for the first two years of temporary closures ...

  2. 36 CFR 13.166 - Temporary facilities.

    Science.gov (United States)

    2010-07-01

    ... 36 Parks, Forests, and Public Property 1 2010-07-01 2010-07-01 false Temporary facilities. 13.166... facilities. A temporary facility or structure directly and necessarily related to the taking of subsistence... facilities which shall be published annually in accordance with § 1.7 of this chapter. ...

  3. On the Sharing of Temporary Parental Leave

    DEFF Research Database (Denmark)

    Amilon, Anna

    2007-01-01

    This paper views temporary parental leave (leave from work to take care of a sick child) as a household public good, produced with time inputs of the parents as the only input. Assuming equal productivities in the production of temporary parental leave and equal utility functions of the spouses...

  4. Guidelines for evaluation of anchorage adequacy for safety-related equipment typically used on WWER-type NPPs

    International Nuclear Information System (INIS)

    Masopust, R.

    1999-01-01

    This report describes the criteria which should be met when the capacity evaluation of anchorage of safety related equipment is performed for the WWER type NPPs. It should be noted that these criteria were developed specifically for anchorage of WWER type equipment and components to the concrete or steel building structures and they cover different types of anchor bolts and other anchorage details which are typical just for the existing, constructed or reconstructed WWER type NPPs. The screening approach for verifying of equipment anchorage presented in this report is based on a combination of inspections, calculations, and engineering judgement

  5. MAXILLARY INCISORS CHANGES DURING SPACE CLOSURE WITH CONVENTIONAL AND SKELETAL ANCHORAGE METHODS: A SYSTEMATIC REVIEW

    Directory of Open Access Journals (Sweden)

    Yasas Shri Nalaka JAYARATNE

    2017-12-01

    Full Text Available Purpose: The objective of this systematic review was to compare the antero-posterior, vertical and angular changes of maxillary incisors with conventional anchorage control techniques and mini-implant based space closure methods. Materials and Methods: The electronic databases Pubmed, Scopus, ISI Web of knowledge, Cochrane Library and Open Grey were searched for potentially eligible studies using a set of predetermined keywords. Full texts meeting the inclusion criteria as well as their references were manually searched. The primary outcome data (linear, angular, and vertical maxillary incisor changes and secondary outcome data (overbite changes, soft tissue changes, biomechanical factors, root resorption and treatment duration were extracted from the selected articles and entered into spreadsheets based on the type of anchorage used. The methodological quality of each study was assessed. Results: Six studies met the inclusion criteria. The amount of incisor retraction was greater with buccally placed mini-implants than conventional anchorage techniques. The incisor retraction with indirect anchorage from palatal mini-implants was less when compared with buccally placed mini-implants. Incisor intrusion occurred with buccal mini-implants, whereas extrusion was seen with conventional anchorage. Limited data on the biomechanical variables or adverse effects such as root resorption were reported in these studies. Conclusion: More RCT’s that take in to account relevant biomechanical variables and employ three-dimensional quantification of tooth movements are required to provide information on incisor changes during space closure.

  6. Maxillary incisors changes during space closure with conventional and skeletal anchorage methods: a systematic review.

    Science.gov (United States)

    Jayaratne, Yasas Shri Nalaka; Uribe, Flavio; Janakiraman, Nandakumar

    2017-01-01

    The objective of this systematic review was to compare the antero-posterior, vertical and angular changes of maxillary incisors with conventional anchorage control techniques and mini-implant based space closure methods. The electronic databases Pubmed, Scopus, ISI Web of knowledge, Cochrane Library and Open Grey were searched for potentially eligible studies using a set of predetermined keywords. Full texts meeting the inclusion criteria as well as their references were manually searched. The primary outcome data (linear, angular, and vertical maxillary incisor changes) and secondary outcome data (overbite changes, soft tissue changes, biomechanical factors, root resorption and treatment duration) were extracted from the selected articles and entered into spreadsheets based on the type of anchorage used. The methodological quality of each study was assessed. Six studies met the inclusion criteria. The amount of incisor retraction was greater with buccally placed mini-implants than conventional anchorage techniques. The incisor retraction with indirect anchorage from palatal mini-implants was less when compared with buccally placed mini-implants. Incisor intrusion occurred with buccal mini-implants, whereas extrusion was seen with conventional anchorage. Limited data on the biomechanical variables or adverse effects such as root resorption were reported in these studies. More RCT's that take in to account relevant biomechanical variables and employ three-dimensional quantification of tooth movements are required to provide information on incisor changes during space closure.

  7. Quantification of temperature effect on impedance monitoring via PZT interface for prestressed tendon anchorage

    Science.gov (United States)

    Huynh, Thanh-Canh; Kim, Jeong-Tae

    2017-12-01

    In this study, the quantification of temperature effect on impedance monitoring via a PZT interface for prestressed tendon-anchorage is presented. Firstly, a PZT interface-based impedance monitoring technique is selected to monitor impedance signatures by predetermining sensitive frequency bands. An analytical model is designed to represent coupled dynamic responses of the PZT interface-tendon anchorage system. Secondly, experiments on a lab-scaled tendon anchorage are described. Impedance signatures are measured via the PZT interface for a series of temperature and prestress-force changes. Thirdly, temperature effects on measured impedance responses of the tendon anchorage are estimated by quantifying relative changes in impedance features (such as RMSD and CCD indices) induced by temperature variation and prestress-force change. Finally, finite element analyses are conducted to investigate the mechanism of temperature variation and prestress-loss effects on the impedance responses of prestressed tendon anchorage. Temperature effects on impedance monitoring are filtered by effective frequency shift-based algorithm for distinguishing prestress-loss effects on impedance signatures.

  8. Feasibility Verification of Mountable PZT-Interface for Impedance Monitoring in Tendon-Anchorage

    Directory of Open Access Journals (Sweden)

    Thanh-Canh Huynh

    2015-01-01

    Full Text Available This study has been motivated to numerically evaluate the performance of the mountable PZT-interface for impedance monitoring in tendon-anchorage. Firstly, electromechanical impedance monitoring and feature classification methods are outlined. Secondly, a structural model of tendon-anchorage subsystem with mountable PZT-interface is designed for impedance monitoring. Finally, the feasibility of the mountable PZT-interface is numerically examined. A finite element (FE model is designed for the lab-scaled tendon-anchorage. The FE model of the PZT-interface is tuned as its impedance signatures meet the experimental test results at the same frequency ranges and also with identical patterns. Equivalent model properties of the FE model corresponding to prestress forces inflicted on the lab-tested structure are identified from the fine-tuning practice.

  9. The anchorage capacity of reinforcing bars at normal and high temperatures

    DEFF Research Database (Denmark)

    Hertz, Kristian Dahl

    1982-01-01

    of the cross-section. A simple method for calculating the resistance to splitting is proposed, and a test method for determining the bond strength is presented. Test results are shown from a series of 280 specimens exposed to various maximum temperatures, and a relation between the bond strength......The anchorage failure of reinforcing bars is analysed, and it is shown that two modes of failures are possible: splitting or bond failure. It is concluded that the anchorage capacity cannot be estimated by means of a standard specimen, since splitting failure is dependent upon the geometry...... and the ultimate limit stress of concrete under plane strain conditions is indicated. The influence of high temperatures upon the anchorage resistance is explained, and the theory is illustrated by examples....

  10. Ground Water in the Anchorage Area, Alaska--Meeting the Challenges of Ground-Water Sustainability

    Science.gov (United States)

    Moran, Edward H.; Galloway, Devin L.

    2006-01-01

    Ground water is an important component of Anchorage's water supply. During the 1970s and early 80s when ground water extracted from aquifers near Ship Creek was the principal source of supply, area-wide declines in ground-water levels resulted in near record low streamflows in Ship Creek. Since the importation of Eklutna Lake water in the late 1980s, ground-water use has been reduced and ground water has contributed 14-30 percent of the annual supply. As Anchorage grows, given the current constraints on the Eklutna Lake water availability, the increasing demand for water could place an increasing reliance on local ground-water resources. The sustainability of Anchorage's ground-water resources challenges stakeholders to develop a comprehensive water-resources management strategy.

  11. Temporary closure of the tunnel

    CERN Multimedia

    Relations with the Host States Service

    2005-01-01

    Owing to major maintenance work, the tunnel linking the various parts of the CERN site will be closed from Monday 4 July to Sunday 24 July 2005 The Host State authorities have given authorisation for persons employed by CERN or the Institutes to travel and for goods belonging to these entities to be transported between the various parts of the site via Gate E (Charles de Gaulle) while this work is being carried out, subject to strict compliance with the Rules for the Use of the Tunnel (see http://dsu.web.cern.ch/dsu/dsum/hsr/DOCUMENTS/8200980415.pdf). Gate E will thus be open between 7.00 a.m. and 7.00 p.m. from Monday to Friday during the period concerned. The rules governing the use of Gate E to enter the Meyrin site between 7.30 a.m. and 9.00 a.m. or to leave the site between 5.00 p.m. and 6.30 p.m. (see http://dsu.web.cern.ch/dsu/dsum/hsr/DOCUMENTS/12222_041027.pdf)) will remain unaffected by this temporary authorisation. Relations with the Host States Service and TS-FM Group

  12. Thick-Walled Cylinder Theory Applied on a Conical Wedge Anchorage

    DEFF Research Database (Denmark)

    Bennitz, Anders; Grip, Niklas; Schmidt, Jacob Wittrup

    2011-01-01

    for further development of the anchorage.In this paper, we derive and examine an analytical model for the internal stresses and strains within the anchorage for a prescribed presetting distance. This model is derived from the theory of thick walled cylinders under the assumptions regarding plane stress...... and axial symmetry. We simplify the resulting system of ten nonlinear equations and derive a method for solving them numerically. A comparison of plotted results for three different angles on the wedge’s outer surface and six different presetting distances follows.These results are also compared to both axi...

  13. Environment - Borrow Area for Temporary Levee

    Data.gov (United States)

    Army Corps of Engineers, Department of the Army, Department of Defense — This data represents the location of a borrow site for construction materials used in temporary levee building during flood events. The footprint of these areas have...

  14. PC based temporary shielding administrative procedure (TSAP)

    International Nuclear Information System (INIS)

    Olsen, D.E.; Pederson, G.E.; Hamby, P.N.

    1995-01-01

    A completely new Administrative Procedure for temporary shielding was developed for use at Commonwealth Edison's six nuclear stations. This procedure promotes the use of shielding, and addresses industry requirements for the use and control of temporary shielding. The importance of an effective procedure has increased since more temporary shielding is being used as ALARA goals become more ambitious. To help implement the administrative procedure, a personal computer software program was written to incorporate the procedural requirements. This software incorporates the useability of a Windows graphical user interface with extensive help and database features. This combination of a comprehensive administrative procedure and user friendly software promotes the effective use and management of temporary shielding while ensuring that industry requirements are met

  15. Temporary Authorizations at Permitted Waste Management Facilities

    Science.gov (United States)

    This rule under the Code of Federal Regulations (CFR) provides EPA with the authority to grant a permittee temporary authorization, without prior public notice and comment, to conduct activities necessary to respond promptly to changing conditions.

  16. PC based temporary shielding administrative procedure (TSAP)

    Energy Technology Data Exchange (ETDEWEB)

    Olsen, D.E.; Pederson, G.E. [Sargent & Lundy, Chicago, IL (United States); Hamby, P.N. [Commonwealth Edison Co., Downers Grove, IL (United States)

    1995-03-01

    A completely new Administrative Procedure for temporary shielding was developed for use at Commonwealth Edison`s six nuclear stations. This procedure promotes the use of shielding, and addresses industry requirements for the use and control of temporary shielding. The importance of an effective procedure has increased since more temporary shielding is being used as ALARA goals become more ambitious. To help implement the administrative procedure, a personal computer software program was written to incorporate the procedural requirements. This software incorporates the useability of a Windows graphical user interface with extensive help and database features. This combination of a comprehensive administrative procedure and user friendly software promotes the effective use and management of temporary shielding while ensuring that industry requirements are met.

  17. 32 CFR 147.32 - Temporary eligibility for access at the top secret and SCI levels and temporary eligibility for...

    Science.gov (United States)

    2010-07-01

    ... Guidelines for Temporary Access § 147.32 Temporary eligibility for access at the top secret and SCI levels... 32 National Defense 1 2010-07-01 2010-07-01 false Temporary eligibility for access at the top secret and SCI levels and temporary eligibility for âQâ access authorization: For someone who is not the...

  18. 32 CFR 147.30 - Temporary eligibility for access at the confidential and secret levels and temporary eligibility...

    Science.gov (United States)

    2010-07-01

    ... 32 National Defense 1 2010-07-01 2010-07-01 false Temporary eligibility for access at the confidential and secret levels and temporary eligibility for âLâ access authorization. 147.30 Section 147.30... Temporary Access § 147.30 Temporary eligibility for access at the confidential and secret levels and...

  19. Electromechanical impedance-based health diagnosis for tendon and anchorage zone in a nuclear containment structure

    Science.gov (United States)

    Min, Jiyoung; Shim, Hyojin; Yun, Chung-Bang

    2012-04-01

    For a nuclear containment structure, the structural health monitoring is essential because of its high potential risk and grave social impact. In particular, the tendon and anchorage zone are to be monitored because they are under high tensile or compressive stress. In this paper, a method to monitor the tendon force and the condition of the anchorage zone is presented by using the impedance-based health diagnosis system. First, numerical simulations were conducted for cases with various loose tensile forces on the tendon as well as damages on the bearing plate and concrete structure. Then, experimental studies were carried out on a scaled model of the anchorage system. The relationship between the loose tensile force and the impedance-based damage index was analyzed by a regression analysis. When a structure gets damaged, the damage index increases so that the status of damage can be identified. The results of the numerical and experimental studies indicate a big potential of the proposed impedance-based method for monitoring the tendon and anchorage system.

  20. Experimental evidence of pharmacological management of anchorage in Orthodontics: A systematic review

    Science.gov (United States)

    Fernández-González, Felipe José; Cañigral, Aránzazu; Balbontín-Ayala, Felipe; Gonzalo-Orden, José Manuel; de Carlos, Felix; Cobo, Teresa; Fernández-Vázquez, Jose Pedro; Sánchez-Lasheras, Fernando; Vega, José Antonio

    2015-01-01

    Introduction: Orthodontic anchorage is one of the most challenging aspects of Orthodontics. Preventing undesired movement of teeth could result in safer and less complicated orthodontic treatment. Recently, several reviews have been published about the effects of different molecules on bone physiology and the clinical side effects in Orthodontics. However, the effects of local application of these substances on the rate of orthodontic tooth movement have not been assessed. Objectives: The aim of this research was to analyze the scientific evidence published in the literature about the effects of different molecules on orthodontic anchorage. Methods: The literature was systematically reviewed using PubMed/Medline, Scopus and Cochrane databases from 2000 up to July 31st, 2014. Articles were independently selected by two different researchers based on previously established inclusion and exclusion criteria, with a concordance Kappa index of 0.86. The methodological quality of the reviewed papers was performed. Results: Search strategy identified 270 articles. Twenty-five of them were selected after application of inclusion/exclusion criteria, and only 11 qualified for final analysis. Molecules involved in orthodontic anchorage were divided into three main groups: osteoprotegerin (OPG), bisphosphonates (BPs) and other molecules (OMs). Conclusions: Different drugs are able to alter the bone remodeling cycle, influencing osteoclast function and, therefore, tooth movement. Thus, they could be used in order to provide maximal anchorage while preventing undesired movements. OPG was found the most effective molecule in blocking the action of osteoclasts, thereby reducing undesired movements. PMID:26560822

  1. Skeletal anchorage in orthodontics : A review of various systems in animal and human studies

    NARCIS (Netherlands)

    Janssen, Krista I.; Raghoebar, Gerry M.; Vissink, Arjan; Sandham, John

    2008-01-01

    Purpose: The aim of the present investigation was to review and evaluate the current literature on skeletal bone anchorage in orthodontics with regard to success rates of the various systems. Materials and Methods: MEDLINE, PubMed, and Cochrane searches (period January 1966 to January 2006, English

  2. A Manual for the Anchorage School District Bilingual Education Program Revised Scope and Sequence, K-3.

    Science.gov (United States)

    Heinrich, Maria Nieves Bumanlag Lilagan

    The manual offers a systematic set of procedures and relevant information to facilitate effective use of the Anchorage school district (ASD) bilingual education program (BEP). The historical background of the program's development is presented, available manuals for teaching English to limited English proficiency (LEP) students and related…

  3. 77 FR 35104 - Notice of Request To Release Airport Property at Merrill Field Airport, Anchorage, AK

    Science.gov (United States)

    2012-06-12

    ... delivered to: Michelle Colby, Real Estate Services Manager, DOWL HKM, 4041 B Street, Anchorage, AK 99503...- 271-3665, email [email protected] or Michelle Colby, Real Estate Services Manager, DOWL HKM, 4041... Section 6.13 of the State of Alaska Right of Way Manual. This purchase offer was predicated on DOT&PF's...

  4. Revisiting the stability of mini-implants used for orthodontic anchorage

    Directory of Open Access Journals (Sweden)

    Chung-Chen Jane Yao

    2015-11-01

    Conclusion: This study revealed that once the dental surgeon becomes familiar with the procedure, the stability of orthodontic mini-implants depends on the type of mini-implant, age of the patient, implantation site, and the healing time of the mini-implant. Miniplates are a more feasible anchorage system when miniscrews fail repeatedly.

  5. Evaluating School Wellness Policy in Curbing Childhood Obesity in Anchorage, Alaska

    Science.gov (United States)

    Parsons, Wendy G.; Garcia, Gabriel M.; Hoffman, Pamela K.

    2014-01-01

    In 2006, the Anchorage School District implemented a school wellness policy to address the problem of obesity among its elementary-aged students. We assessed whether the addition of this policy is effective in protecting or preventing students from becoming overweight/obese over time. The methods involved following two cohorts of students for 5…

  6. SATB2 expression increased anchorage-independent growth and cell migration in human bronchial epithelial cells

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Feng; Jordan, Ashley; Kluz, Thomas [Department of Environmental Medicine, New York University School of Medicine, 57 Old Forge Road, Tuxedo, NY 10987 (United States); Shen, Steven [Center for Health Informatics and Bioinformatics, New York University Langone Medical Center, New York, NY 10016 (United States); Sun, Hong; Cartularo, Laura A. [Department of Environmental Medicine, New York University School of Medicine, 57 Old Forge Road, Tuxedo, NY 10987 (United States); Costa, Max, E-mail: Max.Costa@nyumc.org [Department of Environmental Medicine, New York University School of Medicine, 57 Old Forge Road, Tuxedo, NY 10987 (United States)

    2016-02-15

    The special AT-rich sequence-binding protein 2 (SATB2) is a protein that binds to the nuclear matrix attachment region of the cell and regulates gene expression by altering chromatin structure. In our previous study, we reported that SATB2 gene expression was induced in human bronchial epithelial BEAS-2B cells transformed by arsenic, chromium, nickel and vanadium. In this study, we show that ectopic expression of SATB2 in the normal human bronchial epithelial cell-line BEAS-2B increased anchorage-independent growth and cell migration, meanwhile, shRNA-mediated knockdown of SATB2 significantly decreased anchorage-independent growth in Ni transformed BEAS-2B cells. RNA sequencing analyses of SATB2 regulated genes revealed the enrichment of those involved in cytoskeleton, cell adhesion and cell-movement pathways. Our evidence supports the hypothesis that SATB2 plays an important role in BEAS-2B cell transformation. - Highlights: • We performed SATB2 overexpression in the BEAS-2B cell line. • We performed SATB2 knockdown in a Ni transformed BEAS-2B cell line. • SATB2 induced anchorage-independent growth and increased cell migration. • SATB2 knockdown significantly decreased anchorage-independent growth. • We identified alterations in gene involved in cytoskeleton, cell adhesion.

  7. SATB2 expression increased anchorage-independent growth and cell migration in human bronchial epithelial cells

    International Nuclear Information System (INIS)

    Wu, Feng; Jordan, Ashley; Kluz, Thomas; Shen, Steven; Sun, Hong; Cartularo, Laura A.; Costa, Max

    2016-01-01

    The special AT-rich sequence-binding protein 2 (SATB2) is a protein that binds to the nuclear matrix attachment region of the cell and regulates gene expression by altering chromatin structure. In our previous study, we reported that SATB2 gene expression was induced in human bronchial epithelial BEAS-2B cells transformed by arsenic, chromium, nickel and vanadium. In this study, we show that ectopic expression of SATB2 in the normal human bronchial epithelial cell-line BEAS-2B increased anchorage-independent growth and cell migration, meanwhile, shRNA-mediated knockdown of SATB2 significantly decreased anchorage-independent growth in Ni transformed BEAS-2B cells. RNA sequencing analyses of SATB2 regulated genes revealed the enrichment of those involved in cytoskeleton, cell adhesion and cell-movement pathways. Our evidence supports the hypothesis that SATB2 plays an important role in BEAS-2B cell transformation. - Highlights: • We performed SATB2 overexpression in the BEAS-2B cell line. • We performed SATB2 knockdown in a Ni transformed BEAS-2B cell line. • SATB2 induced anchorage-independent growth and increased cell migration. • SATB2 knockdown significantly decreased anchorage-independent growth. • We identified alterations in gene involved in cytoskeleton, cell adhesion.

  8. Distinct spinning patterns gain differentiated loading tolerance of silk thread anchorages in spiders with different ecology.

    Science.gov (United States)

    Wolff, Jonas O; van der Meijden, Arie; Herberstein, Marie E

    2017-07-26

    Building behaviour in animals extends biological functions beyond bodies. Many studies have emphasized the role of behavioural programmes, physiology and extrinsic factors for the structure and function of buildings. Structure attachments associated with animal constructions offer yet unrealized research opportunities. Spiders build a variety of one- to three-dimensional structures from silk fibres. The evolution of economic web shapes as a key for ecological success in spiders has been related to the emergence of high performance silks and thread coating glues. However, the role of thread anchorages has been widely neglected in those models. Here, we show that orb-web (Araneidae) and hunting spiders (Sparassidae) use different silk application patterns that determine the structure and robustness of the joint in silk thread anchorages. Silk anchorages of orb-web spiders show a greater robustness against different loading situations, whereas the silk anchorages of hunting spiders have their highest pull-off resistance when loaded parallel to the substrate along the direction of dragline spinning. This suggests that the behavioural 'printing' of silk into attachment discs along with spinneret morphology was a prerequisite for the evolution of extended silk use in a three-dimensional space. This highlights the ecological role of attachments in the evolution of animal architectures. © 2017 The Author(s).

  9. 77 FR 8252 - Adequacy Status of the Anchorage, Alaska, Carbon Monoxide Maintenance Plan for Transportation...

    Science.gov (United States)

    2012-02-14

    ... a SIP means that transportation activities will not produce new air quality violations, worsen... Anchorage, Alaska, Carbon Monoxide Maintenance Plan for Transportation Conformity Purposes AGENCY... Transportation & Public Facilities, and the U.S. Department of Transportation will be required to use [[Page 8253...

  10. Fatigue of cable anchorage of large cable stayed bridge; Daikibo shachokyo cable teichaku kozo no hiro

    Energy Technology Data Exchange (ETDEWEB)

    Endo, T.; Matsumoto, T. [Honshu-Shikoku Bridge Authority, Tokyo (Japan); Tsukahara, H. [Yokogawa Bridge Corp., Tokyo (Japan); Miki, C. [Tokyo Institute of Technology, Tokyo (Japan)

    1995-10-21

    Design considerations such as design schemes, the assemblage and welding of steel plates, and safety for fatigue of welded connections have to be taken for the cable anchorages of the steel cable stayed bridges. In this study, two full scale models, which have different shape of box anchorages welded to the web of the main girder, were made to investigate fatigue characteristics as well as assemblage of plate and gelding details. Finite element analyses for both test models and actual bridges here carried out to compare stress distribution. It was confirmed that the assemblage and welding of both types of box anchorage were attainable kith required quality and accuracy. According to the fatigue test, fatigue cracks originated from the weldings of the bearing plate to which the load from cable socket applied directly were caused by out-of-plane bending of the bearing plate. It was proved that the slight modifications of the details around the bearing plate resulted in sufficient fatigue strength in both types of anchorage. 1 ref., 23 figs., 2 tabs.

  11. Behaviour of Prestressed CFRP Anchorages during and after Freeze-Thaw Cycle Exposure

    Directory of Open Access Journals (Sweden)

    Yunus Emre Harmanci

    2018-05-01

    Full Text Available The long-term performance of externally-bonded reinforcements (EBR on reinforced concrete (RC structures highly depends on the behavior of constituent materials and their interfaces to various environmental loads, such as temperature and humidity exposure. Although significant efforts have been devoted to understanding the effect of such conditions on the anchorage resistance of unstressed EBR, with or without sustained loading, the effect of a released prestressing has not been thoroughly investigated. For this purpose, a series of experiments has been carried out herein, with concrete blocks strengthened with carbon fiber-reinforced polymer (CFRP strips, both unstressed, as well as prestressed using the gradient anchorage. The gradient anchorage is a non-mechanical technique to anchor prestressed CFRP by exploiting the accelerated curing property of epoxy under higher temperatures and segment-wise prestress-force releasing. Subsequently, strengthened blocks are transferred into a chamber for exposure in dry freeze-thaw cycles (FTC. Following FTC exposure, the blocks are tested in a conventional lap-shear test setup to determine their residual anchorage resistance and then compared with reference specimens. Blocks were monitored during FTC by conventional and Fabry–Pérot-based fiber optic strain (FOS sensors and a 3D-digital image correlation (3D-DIC system during gradient application and lap-shear testing. Results indicate a reduction of residual anchorage resistance, stiffness and deformation capacity of the system after FTC and a change in the failure mode from concrete substrate to epoxy-concrete interface failure. It was further observed that all of these properties experienced a more significant reduction for prestressed specimens. These findings are presented with a complementary finite element model to shed more light onto the durability of such systems.

  12. [Temporary disability and its legal implications].

    Science.gov (United States)

    Martin-Fumadó, Carles; Martí Amengual, Gabriel; Puig Bausili, Lluïsa; Arimany-Manso, Josep

    2014-03-01

    Temporary disability is the condition that workers face when, as the result of illness (common or professional) or accident (work-related or not), they are temporarily prevented from performing their work and require health care. The management of temporary disability is a medical act that involves (in addition to a complex clinical assessment) obvious social, occupational and financial connotations and requires continuing medical follow-up from doctors, as well as responses to medical-legal conflicts. The regulatory framework on the subject is extensive in the Spanish setting and highly diverse in the European setting. Beyond the regulatory framework, the repercussions of temporary disability are self-evident at all levels. Although determining temporary disability is a common medical act for practicing physicians, it is not exempt from risks or difficulties arising from the assessment itself and the characteristics of practicing medical care. Established medical-legal conflicts include the processing of health data and the requirements for transferring information related to workers' temporary disability to their company's medical services. The interest and usefulness demonstrated by the data obtained from forensic medicine for public health require the incorporation of these data into general healthcare information, as it could be essential to the surveillance of worker health. The recommendations established by medical societies, as good practice guidelines, are especially useful in this type of conflict. Copyright © 2014 Elsevier España, S.L. All rights reserved.

  13. Device for cutting protrusions

    Science.gov (United States)

    Bzorgi, Fariborz M [Knoxville, TN

    2011-07-05

    An apparatus for clipping a protrusion of material is provided. The protrusion may, for example, be a bolt head, a nut, a rivet, a weld bead, or a temporary assembly alignment tab protruding from a substrate surface of assembled components. The apparatus typically includes a cleaver having a cleaving edge and a cutting blade having a cutting edge. Generally, a mounting structure configured to confine the cleaver and the cutting blade and permit a range of relative movement between the cleaving edge and the cutting edge is provided. Also typically included is a power device coupled to the cutting blade. The power device is configured to move the cutting edge toward the cleaving edge. In some embodiments the power device is activated by a momentary switch. A retraction device is also generally provided, where the retraction device is configured to move the cutting edge away from the cleaving edge.

  14. Temporary quadriplegia following continuous thoracic paravertebral block.

    Science.gov (United States)

    Calenda, Emile; Baste, Jean Marc; Danielou, Eric; Michelin, Paul

    2012-05-01

    A case of temporary quadriplegia following a continuous thoracic paravertebral block in an adult patient scheduled for video-assisted thoracoscopy is presented. An 18-gauge Tuohy needle was inserted under direct vision by the surgeon but the tip of the catheter was not localized. Postoperatively, the patient developed temporary quadriplegia 90 minutes after the start of a continuous infusion of ropivacaine 0.2%. Imaging studies showed that the catheter was localized in the intrathecal space. Copyright © 2012 Elsevier Inc. All rights reserved.

  15. Herbst appliance with skeletal anchorage versus dental anchorage in adolescents with Class II malocclusion: study protocol for a randomised controlled trial.

    Science.gov (United States)

    Batista, Klaus Barretto Dos Santos Lopes; Lima, Tatiana; Palomares, Nathália; Carvalho, Felipe de Assis; Quintão, Cátia; Miguel, José Augusto Mendes; Lin, Yin-Ling; Su, Ting-Li; O'Brien, Kevin

    2017-11-25

    The Herbst appliance is an orthodontic appliance that is used for the correction of class II malocclusion with skeletal discrepancies. Research has shown that this is effective. However, a potential harm is excessive protrusion of the lower front teeth. This is associated with gingival recession, loss of tooth support, and root resorption. This trial evaluates a method of reducing this problem. The study is a single-center, randomised, assessor-blinded, superiority clinical trial with parallel 1:1 allocation. Male and female young people (10-14 years old) with prominent front teeth (class II, division 1) will be treated in one orthodontic clinic. Group 1 will be treated with the conventional Herbst appliance with dental anchorage and group 2 with the Herbst appliance with indirect skeletal anchorage for 12 months. The primary objective will be to compare the proclination of the lower incisors between the Herbst appliance with dental anchorage and skeletal anchorage. Secondary objectives will be to evaluate the changes occurring between the groups in the mandible, maxilla, lower and upper molars, and in gingival recession and root resorption at the end of the treatment. Additionally, the young patient's experience using the appliances will be assessed. The primary outcome measure will be the amount of lower incisor proclination at the end of treatment. This will be assessed by cone-beam computed tomography (CBCT) superimposition. Secondary outcome measures will be the changes in the mandible, maxilla, lower and upper molars at the end of treatment assessed by tomography superimposition and the young patient's experience using the appliances assessed by self-reported questionnaires and semi-structured interviews. The randomisation method will be blocked randomisation, using software to generate a randomised list. The allocation concealment will be done in opaque envelopes numbered from 1 to 40 containing the treatment modality. The randomisation will be

  16. Managing Conflict in Temporary Management Systems

    Science.gov (United States)

    Wilemon, David L.

    1973-01-01

    As organizational tasks have grown more complex, several innovative temporary management systems such as matrix management have been developed. The Apollo space program has been an important contribution to the development of matrix management techniques. Discusses the role of conflict within the matrix, its determinants, and the process of…

  17. 78 FR 24239 - Temporary Mailing Promotion

    Science.gov (United States)

    2013-04-24

    ... POSTAL REGULATORY COMMISSION [Docket No. R2013-6; Order No. 1702] Temporary Mailing Promotion... offering a Technology Credit Promotion. This notice informs the public of the Postal Service's filing and... changes associated with offering a Technology Credit Promotion.\\1\\ The promotion is planned to begin on...

  18. Ambiguous diagnosis, futile treatments and temporary recovery ...

    African Journals Online (AJOL)

    Ambiguous diagnosis, futile treatments and temporary recovery: Meanings of medical treatment among HIV/AIDS family caregivers providing care without ARVs. ... to understand unstable treatment outcomes; and policy makers should strengthen home-based care by developing policies that integrate palliative care into HIV ...

  19. Meaningful radiation worker training for temporary craftsmen

    International Nuclear Information System (INIS)

    Williams, S.L.

    1976-01-01

    The carefully organized Radiation Worker Training Program presented to permanently assigned personnel at a power reactor facility too often falls by the wayside when temporary craftsmen are brought in for an outage. Even though these temporary workers will frequently be assigned to outage jobs with high radiation and/or contamination exposures, their Radiation Worker Training is often squeezed into an already busy schedule, thus reducing its effectiveness. As an aid for evaluating the effectiveness of an existing Radiation Worker Training Program for temporary craftsmen or for setting up a new program, the following guides are presented and discussed in this paper: the training environment; the interest and meaningfulness of the presentation; the method or methods used for presentation of the training information; the use of demonstrations; trainee participation; and, measuring the amount and type of information retained by a trainee. Meaningful Radiation Worker Training for temporary craftsmen can pay big dividends. Craftsmen can be expected to make fewer mistakes, thus reducing radiation exposure and lessening the chance for the spread of contamination. The craftsmen will also benefit by being able to work longer and utility management will benefit by having lower outage costs

  20. 40 CFR 82.65 - Temporary exemptions.

    Science.gov (United States)

    2010-07-01

    ...) PROTECTION OF STRATOSPHERIC OZONE Ban on Nonessential Products Containing Class I Substances and Ban on Nonessential Products Containing or Manufactured With Class II Substances § 82.65 Temporary exemptions. (a) Any... January 1, 1996. (e) Any person selling or distributing, or offering to sell or distribute, any product...

  1. Temporary tattoos: a novel OSCE assessment tool.

    Science.gov (United States)

    Gormley, Gerry; Menary, Allison; Layard, Brooke; Hart, Nigel; McCourt, Collette

    2013-08-01

    There are many issues regarding the use of real patients in objective structured clinical examinations (OSCEs). In dermatology OSCE stations, standardised patients (SPs) with clinical photographs are often used. Temporary transfer tattoos can potentially simulate skin lesions when applied to an SP. This study aims to appraise the use of temporary malignant melanoma tattoos within an OSCE framework. Within an 11-station OSCE, a temporary malignant melanoma tattoo was developed and applied to SPs in a 'skin lesion' OSCE station. A questionnaire captured the opinions of the candidate, SP and examiners, and the degree of perceived realism of each station was determined. Standard post hoc OSCE analysis determined the psychometric reliability of the stations. The response rates were 95.9 per cent of candidates and 100 per cent of the examiners and SPs. The 'skin lesion' station achieved the highest realism score compared with other stations: 89.0 per cent of candidates felt that the skin lesion appeared realistic; only 28 per cent of candidates had ever seen a melanoma before in training. The psychometric performance of the melanoma station was comparable with, and in many instances better than, other OSCE stations. Transfer tattoo technology facilitates a realistic dermatology OSCE station encounter. Temporary tattoos, alongside trained SPs, provide an authentic, standardised and reliable experience, allowing the assessment of integrated dermatology clinical skills. © 2013 John Wiley & Sons Ltd.

  2. Closing a temporary ileostomy within two weeks

    DEFF Research Database (Denmark)

    Hindenburg, Tommy; Rosenberg, J.

    2010-01-01

    Temporary ileostomy is frequently constructed to relieve a rectal anastomosis and avoid peritonitis if the anastomosis is leaking. Ostomy is a burden for both the patient and society and early closure is therefore desirable to counteract increased morbidity. Several prospective studies and a single...

  3. Temporary/portable nuclear fallout shelter

    Energy Technology Data Exchange (ETDEWEB)

    Hampel, V E

    1991-01-15

    The design and invention of a temporary/portable fallout shelter has been described in context of schematic and representative embodiments. Tent structures are described which include disposable, exterior, semi-transparent plastic and/or fabric shield membranes covering a tent composed of stretched, tightly woven, rip-resistant fabric panels supported by tensile rods/wands. 16 figs.

  4. Anchorage onto deciduous teeth: effectiveness of early rapid maxillary expansion in increasing dental arch dimension and improving anterior crowding

    OpenAIRE

    Mutinelli, Sabrina; Manfredi, Mario; Guiducci, Antonio; Denotti, Gloria; Cozzani, Mauro

    2015-01-01

    Background Anchorage onto permanent dentition is a common procedure in rapid maxillary expansion. However, replacing first permanent molars with the second deciduous molars seems to be an option to reduce some negative side effects during orthodontic treatment. The purpose of this study was to evaluate the dental effect of rapid maxillary expansion with anchorage exclusively onto deciduous teeth performed in the first period of transition. Methods Twenty patients with a lateral cross-bite tre...

  5. Customized lingual bracket system and skeletal anchorage system for open bite correction

    Directory of Open Access Journals (Sweden)

    Toru Inami

    2016-01-01

    Full Text Available We treated a female patient with open bite and high-angle Class II Division 2 malocclusion using fully customized lingual appliances, orthodontic anchor screws (OAS, and a skeletal anchorage system (SAS. By carefully controlling torque, anchorage, and vertical skeletal and dental factors, we were able to obtain proper anterior coupling. Even after the retention phase of treatment, the occlusion was maintained, indicating that we provided proper treatment according to the properly designed treatment plan. This also indicates that cases with an extremely high level of difficulty, as in the present case with high-angle retrognathic mandible and open bite, can be treated by combining the Incognito appliance (a fully customized lingual bracket appliance with a SAS and OAS.

  6. Numerical implementation of multiple peeling theory and its application to spider web anchorages.

    Science.gov (United States)

    Brely, Lucas; Bosia, Federico; Pugno, Nicola M

    2015-02-06

    Adhesion of spider web anchorages has been studied in recent years, including the specific functionalities achieved through different architectures. To better understand the delamination mechanisms of these and other biological or artificial fibrillar adhesives, and how their adhesion can be optimized, we develop a novel numerical model to simulate the multiple peeling of structures with arbitrary branching and adhesion angles, including complex architectures. The numerical model is based on a recently developed multiple peeling theory, which extends the energy-based single peeling theory of Kendall, and can be applied to arbitrarily complex structures. In particular, we numerically show that a multiple peeling problem can be treated as the superposition of single peeling configurations even for complex structures. Finally, we apply the developed numerical approach to study spider web anchorages, showing how their function is achieved through optimal geometrical configurations.

  7. Branded prescription drug fee. Final regulations, temporary regulations, and removal of temporary regulations.

    Science.gov (United States)

    2014-07-28

    This document contains final regulations that provide guidance on the annual fee imposed on covered entities engaged in the business of manufacturing or importing branded prescription drugs. This fee was enacted by section 9008 of the Patient Protection and Affordable Care Act, as amended by section 1404 of the Health Care and Education Reconciliation Act of 2010. This document also withdraws the Branded Prescription Drug Fee temporary regulations and contains new temporary regulations regarding the definition of controlled group that apply beginning on January 1, 2015. The final regulations and the new temporary regulations affect persons engaged in the business of manufacturing or importing certain branded prescription drugs. The text of the temporary regulations in this document also serves as the text of proposed regulations set forth in a notice of proposed rulemaking (REG-123286-14) on this subject in the Proposed Rules section in this issue of the Federal Register.

  8. Dental Extrusion with Orthodontic Miniscrew Anchorage: A Case Report Describing a Modified Method

    OpenAIRE

    Horliana, Ricardo Fidos; Horliana, Anna Carolina Ratto Tempestini; Wuo, Alexandre do Vale; Perez, Fl?vio Eduardo Guillin; Abr?o, Jorge

    2015-01-01

    In recent years, the skeletal anchorage through miniscrews has expanded the treatment options in orthodontics (Yamaguchi et al., 2012). We hereby present a modified method for tooth extrusion for cases where crown-lengthening surgery is contraindicated for aesthetic reasons. This modified method uses three orthodontic appliances: a mini-implant, an orthodontic wire, and a bracket. The aim of this case report was to increase the length of the clinical crown of a fractured tooth (tooth 23) by m...

  9. Orthodontic retreatment using anchorage with miniplate to camouflage a Class III skeletal pattern

    OpenAIRE

    Farret,Marcel Marchiori

    2016-01-01

    ABSTRACT This manuscript describes the treatment of a 27-year-old patient who was previously treated with two maxillary first premolar extractions. The patient had skeletal Class III malocclusion, Class III canine relationship, anterior crossbite, and a concave profile. As the patient refused orthognathic surgery, a miniplate was used on the right side of the lower arch as an anchorage unit after the extraction of mandibular first premolars, aiding the retraction of anterior teeth. At the end...

  10. Maxillary distraction osteogenesis in cleft lip and palate patients with skeletal anchorage.

    Science.gov (United States)

    Minami, Katsuhiro; Mori, Yoshihide; Tae-Geon, Kwon; Shimizu, Hidetaka; Ohtani, Miyuki; Yura, Yoshiaki

    2007-03-01

    Maxillary distraction osteogenesis with the rigid external distraction (RED) system has been used to treat cleft lip and palate (CLP) patients with severe maxillary hypoplasia. We introduce maxillary distraction osteogenesis for CLP patients with skeletal anchorage adapted on a stereolithographic model. Six maxillary deficiency CLP patients treated according to our CLP treatment protocol had undergone maxillary distraction osteogenesis. In all patients, computed tomography (CT) images were recorded preoperatively, and the data were transferred to a workstation. Three-dimensional skeletal structures were reconstructed with CT data sets, and a stereolithographic model was produced. On the stereolithographic model, miniplates were adapted to the surface of maxilla beside aperture piriforms. The operation performed involved a high Le Fort I osteotomy with pterygomaxillary disjunction. Miniplates were fixed to the maxillary segment with three or four screws and used for anchorage of the RED system. Retraction of the maxillary segment was initiated after 1 week. The accuracy of the stereolithographic models was enough to adapt the miniplates so that there was no need to readjust the plates during surgery. Postoperative cephalometric analysis showed that the direction of the retraction was almost parallel to the palatal plane, and dental compensation did not occur. We performed maxillary distraction osteogenesis with skeletal anchorage adapted on the stereolithographic models. Excellent esthetic outcome and skeletal advancement were achieved without dentoalveolar compensations.

  11. The Plurality of Harbors at Caesarea: The Southern Anchorage in Late Antiquity

    Science.gov (United States)

    Ratzlaff, Alexandra; Galili, Ehud; Waiman-Barak, Paula; Yasur-Landau, Assaf

    2017-08-01

    The engineering marvel of Sebastos, or Portus Augusti as it was called in Late Antiquity (284-638 CE), dominated Caesarea's harbor center along modern Israel's central coast but it was only one part of a larger maritime complex. The Southern Anchorage provides a case study as one portion of the Caesarea complex, as well as a node within the regional network of anchorages and small harbors. Ceramics recovered from here show a high percentage of locally, and provincially, produced storage jars engaged in maritime trade. The ceramic evidence points towards an intensified regional trade or cabotage rather than favouring long distance trade from large port to port. Working out of these small harbors, opportunities arose for greater flexibility in specialization of commodities and materials passing through the network of subsidiary ports, contributing to a more diversified market economy. This analysis provides another example in the growing focus on how these simple and semi-modified anchorages in the Eastern Mediterranean were often the predominant economic networks connecting hinterland and coastal trade.

  12. Success rates of a skeletal anchorage system in orthodontics: A retrospective analysis.

    Science.gov (United States)

    Lam, Raymond; Goonewardene, Mithran S; Allan, Brent P; Sugawara, Junji

    2018-01-01

    To evaluate the premise that skeletal anchorage with SAS miniplates are highly successful and predictable for a range of complex orthodontic movements. This retrospective cross-sectional analysis consisted of 421 bone plates placed by one clinician in 163 patients (95 female, 68 male, mean age 29.4 years ± 12.02). Simple descriptive statistics were performed for a wide range of malocclusions and desired movements to obtain success, complication, and failure rates. The success rate of skeletal anchorage system miniplates was 98.6%, where approximately 40% of cases experienced mild complications. The most common complication was soft tissue inflammation, which was amenable to focused oral hygiene and antiseptic rinses. Infection occurred in approximately 15% of patients where there was a statistically significant correlation with poor oral hygiene. The most common movements were distalization and intrusion of teeth. More than a third of the cases involved complex movements in more than one plane of space. The success rate of skeletal anchorage system miniplates is high and predictable for a wide range of complex orthodontic movements.

  13. A review on the technical basis for ACI 349 code revision to anchorage criteria

    International Nuclear Information System (INIS)

    Lee, N. H.; You, S. H.

    1999-01-01

    Anchors are widely used to attach structural and nonstructural elements to concrete in nuclear power plant construction. Anchorage to concrete in nuclear-related structure plant has been designed per ACI 349-90 Appendix B. However, a new criteria for anchorage based on the concrete capacity design(CCD) approach is ready for publication under the normal publication procedures by ACI 349 Code Committee. Both design procedures(ACI 349-90 and ACI 349-New) show rather different concrete capacities. Earlier comparable studies show that the CCD method is a more reliable predictor of concrete breakout than the 45-degree cone method(ACI 349-90), hence the CCD method adopted by ACI 349-New Code has been recommended. The philosophy of the current code is to design ductile fastenings, which requires a limit to guard against brittle concrete failure. On the other hand, the new code requires calculations for the concrete breakout strength, pullout strength, side-face blowout strength of fastener in tension, and concrete breakout strength, pryout strength of fastener in shear. Therefore, the new code can accurately predict the concrete failure capacity for different behavior of the anchorage system. In this review, the provisions of ACI 349-90 and ACI 349-New are compared to show the major differences with emphasis on the concrete breakout capacity

  14. Temporary Employment and Perceived Employability: Mediation by Impression Management

    Science.gov (United States)

    De Cuyper, Nele; De Witte, Hans

    2010-01-01

    Perceived employability (PE) has been advanced as the upcoming resource for career development, particularly for temporary workers. The question is how temporary workers become employable. Our hypothesis is that temporary workers more than permanent workers use impression management to become employable, both on the internal and the external labor…

  15. 30 CFR 47.44 - Temporary, portable containers.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Temporary, portable containers. 47.44 Section... TRAINING HAZARD COMMUNICATION (HazCom) Container Labels and Other Forms of Warning § 47.44 Temporary, portable containers. (a) The operator does not have to label a temporary, portable container if he or she...

  16. 19 CFR 210.52 - Motions for temporary relief.

    Science.gov (United States)

    2010-04-01

    ....52 Customs Duties UNITED STATES INTERNATIONAL TRADE COMMISSION INVESTIGATIONS OF UNFAIR PRACTICES IN IMPORT TRADE ADJUDICATION AND ENFORCEMENT Temporary Relief § 210.52 Motions for temporary relief... issuance of temporary relief, the Commission will be guided by practice under Rule 65 of the Federal Rules...

  17. 77 FR 15650 - Fisher House and Other Temporary Lodging

    Science.gov (United States)

    2012-03-16

    ... DEPARTMENT OF VETERANS AFFAIRS 38 CFR Part 60 RIN 2900-AN79 Fisher House and Other Temporary... Affairs (VA) proposes to amend its regulations concerning Fisher House and other temporary lodging... assistance and clarify the distinctions between Fisher House and other temporary lodging provided by VA. The...

  18. 46 CFR 112.01-15 - Temporary emergency power source.

    Science.gov (United States)

    2010-10-01

    ... EMERGENCY LIGHTING AND POWER SYSTEMS Definitions of Emergency Lighting and Power Systems § 112.01-15 Temporary emergency power source. A temporary emergency power source is one of limited capacity that carries... 46 Shipping 4 2010-10-01 2010-10-01 false Temporary emergency power source. 112.01-15 Section 112...

  19. 77 FR 71825 - Notice of Temporary Restriction of Vehicle Use and Temporary Closure to Tree Cutting and Wood...

    Science.gov (United States)

    2012-12-04

    ... to Tree Cutting and Wood Harvesting on Public Land in Douglas County, NV AGENCY: Bureau of Land... a temporary closure to wood harvesting and/or tree cutting on public land within the Topaz Ranch... temporary restriction of cross-country vehicle travel and a temporary closure to tree cutting and wood...

  20. Anchorage of equipment - requirements and verification methods with emphasis on equipment of existing and constructed VVER-type nuclear power plants

    International Nuclear Information System (INIS)

    Masopust, R.

    1999-01-01

    Criteria and verification methods which are recommended for use in the capacity evaluation of anchorage of safety-related equipment at WWER-type nuclear power plants are presented. Developed in compliance with the relevant basic standards documents specifically for anchorage of WWER-type equipment components, the criteria and methods cover different types of anchor bolts and other anchorage elements which are typical of existing, constructed, or reconstructed WWER-type nuclear power plants

  1. Temporary Blindness after Inferior Alveolar Nerve Block.

    Science.gov (United States)

    Barodiya, Animesh; Thukral, Rishi; Agrawal, Shaila Mahendra; Rai, Anshul; Singh, Siddharth

    2017-03-01

    Inferior Alveolar Nerve Block (IANB) anaesthesia is one of the common procedures in dental clinic. This procedure is safe, but complications may still occur. Ocular complications such as diplopia, loss of vision, or ophthalmoplegia are extremely rare. This case report explains an event where due to individual anatomic variation of the sympathetic vasoconstrictor nerve and maxillary and middle meningeal arteries, intravascular administration of anaesthetic agent caused unusual ocular signs and symptoms such as temporary blindness.

  2. Comparative evaluation of sagittal anchorage loss in lingual and labial appliances during space closure: A pilot study

    Directory of Open Access Journals (Sweden)

    Shivanand Venkatesh

    2015-01-01

    Full Text Available Aim: The purpose of this investigation was to assess and compare the anchorage loss between labial and lingual appliance systems during space closure. Materials and Methods: Twenty subjects were part of the study among which 10 subjects (mean age 21 ± 3.6 years were treated using lingual appliance system (0.018" slot-STb™ and 10 subjects (mean age 19 ± 6.1 years were treated using labial preadjusted edgewise appliance system (0.018" slot-MBT™ . First premolar extractions were performed to enable retraction of anterior teeth. Lateral cephalometric radiographs were taken at two intervals, before starting space closure and after space closure that were connoted as T0 and T1 and were analyzed using the method described by Pancherz to measure anchorage loss. Intraclass correlation coefficient (ICC was used to evaluate intraexaminer reliability of the measurements. Student′s t-test was performed to verify any statistical significant correlation between the labial and lingual appliance systems. Statistical differences were determined at the 95% confidence level (P < 0.05. Results: The results showed that all ICC for lingual and labial group were ≥0.90 showing good repeatability of the measurements. Mean anchorage loss of 1.238 ± 0.17 mm in lingual appliance system and an anchorage loss of 2.06 ± 0.39 mm occurred with the labial appliance system. On the comparison between the two appliance systems, lingual appliance demonstrated a significantly lesser anchorage loss than did the labial appliance. Interpretation and Conclusion: This prospective study concludes with the fact that lingual appliance provided better anchorage control than labial appliance during space closure. Use of lingual appliance could be considered in critical anchorage cases when compared with labial appliance.

  3. The open abdomen and temporary abdominal closure systems--historical evolution and systematic review.

    Science.gov (United States)

    Quyn, A J; Johnston, C; Hall, D; Chambers, A; Arapova, N; Ogston, S; Amin, A I

    2012-08-01

    Several techniques for temporary abdominal closure have been developed. We systematically review the literature on temporary abdominal closure to ascertain whether the method can be tailored to the indication. Medline, Embase, the Cochrane Central Register of Controlled Trials and relevant meeting abstracts until December 2009 were searched using the following headings: open abdomen, laparostomy, VAC (vacuum assisted closure), TNP (topical negative pressure), fascial closure, temporary abdominal closure, fascial dehiscence and deep wound dehiscence. The data were analysed by closure technique and aetiology. The primary end-points included delayed fascial closure and in-hospital mortality. The secondary end-points were intra-abdominal complications. The search identified 106 papers for inclusion. The techniques described were VAC (38 series), mesh/sheet (30 series), packing (15 series), Wittmann patch (eight series), Bogotá bag (six series), dynamic retention sutures (three series), zipper (15 series), skin only and locking device (one series each). The highest facial closure rates were seen with the Wittmann patch (78%), dynamic retention sutures (71%) and VAC (61%). Temporary abdominal closure has evolved from simple packing to VAC based systems. In the absence of sepsis Wittmann patch and VAC offered the best outcome. In its presence VAC had the highest delayed primary closure and the lowest mortality rates. However, due to data heterogeneity only limited conclusions can be drawn from this analysis. © 2012 The Authors. Colorectal Disease © 2012 The Association of Coloproctology of Great Britain and Ireland.

  4. A genetic screen for anchorage-independent proliferation in mammalian cells identifies a membrane-bound neuregulin.

    Directory of Open Access Journals (Sweden)

    Davide Danovi

    2010-07-01

    Full Text Available Anchorage-independent proliferation is a hallmark of oncogenic transformation and is thought to be conducive to proliferation of cancer cells away from their site of origin. We have previously reported that primary Schwann cells expressing the SV40 Large T antigen (LT are not fully transformed in that they maintain a strict requirement for attachment, requiring a further genetic change, such as oncogenic Ras, to gain anchorage-independence. Using the LT-expressing cells, we performed a genetic screen for anchorage-independent proliferation and identified Sensory and Motor Neuron Derived Factor (SMDF, a transmembrane class III isoform of Neuregulin 1. In contrast to oncogenic Ras, SMDF induced enhanced proliferation in normal primary Schwann cells but did not trigger cellular senescence. In cooperation with LT, SMDF drove anchorage-independent proliferation, loss of contact inhibition and tumourigenicity. This transforming ability was shared with membrane-bound class III but not secreted class I isoforms of Neuregulin, indicating a distinct mechanism of action. Importantly, we show that despite being membrane-bound signalling molecules, class III neuregulins transform via a cell intrinsic mechanism, as a result of constitutive, elevated levels of ErbB signalling at high cell density and in anchorage-free conditions. This novel transforming mechanism may provide new targets for cancer therapy.

  5. Impact of a new gasoline benzene regulation on ambient air pollutants in Anchorage, Alaska

    Science.gov (United States)

    Yano, Yuriko; Morris, Stephen S.; Salerno, Christopher; Schlapia, Anne M.; Stichick, Mathew

    2016-05-01

    The purpose of this study was to quantify the impact of a new U.S. Environmental Protection Agency (EPA) standard that limits the amount of benzene allowed in gasoline on ambient benzene concentrations. This new standard, together with two companion regulations that limit cold-temperature automotive emissions and the permeability of portable fuel containers, was expected to lower the levels of ambient benzene and other volatile organic compounds (VOCs) nationwide. In this study the impact of the gasoline benzene standard was evaluated in Anchorage, Alaska in a two-phase ambient air monitoring study conducted before and after the new gasoline standard was implemented. Gasoline sold by Anchorage retailers was also evaluated in each phase to determine the content of benzene and other gasoline components. The average benzene content in Anchorage gasoline was reduced by 70%, from 5.05% (w/w) to 1.53% (w/w) following the implementation of the standard. The annual mean ambient benzene concentration fell by 51%, from 0.99 ppbv in Phase 1 to 0.49 ppbv in Phase 2. Analysis suggests the change in gasoline benzene content alone reduced benzene emissions by 46%. The changes in toluene, ethylbenzene, and xylene content in gasoline between Phase 1 and 2 were relatively small and the differences in the mean ambient concentrations of these compounds between phases were modest. Our results suggest that cold winter communities in high latitude and mountainous regions may benefit more from the gasoline benzene standard because of high benzene emissions resulting from vehicle cold start and a tendency to develop atmospheric stagnation conditions in the winter.

  6. Strontium ranelate improved tooth anchorage and reduced root resorption in orthodontic treatment of rats.

    Science.gov (United States)

    Kirschneck, Christian; Wolf, Michael; Reicheneder, Claudia; Wahlmann, Ulrich; Proff, Peter; Roemer, Piero

    2014-12-05

    The anchorage mechanisms currently used in orthodontic treatment have various disadvantages. The objective of this study was to determine the applicability of the osteoporosis medication strontium ranelate in pharmacologically induced orthodontic tooth anchorage. In 48 male Wistar rats, a constant orthodontic force of 0.25 N was reciprocally applied to the upper first molar and the incisors by means of a Sentalloy(®) closed coil spring for two to four weeks. 50% of the animals received strontium ranelate at a daily oral dosage of 900 mg per kilogramme of body weight. Bioavailability was determined by blood analyses. The extent of tooth movement was measured both optometrically and cephalometrically (CBCT). Relative alveolar gene expression of osteoclastic markers and OPG-RANKL was assessed by qRT-PCR and root resorption area and osteoclastic activity were determined in TRAP-stained histologic sections of the alveolar process. Compared to controls, the animals treated with strontium ranelate showed up to 40% less tooth movement after four weeks of orthodontic treatment. Gene expression and histologic analyses showed significantly less osteoclastic activity and a significantly smaller root resorption area. Blood analyses confirmed sufficient bioavailability of strontium ranelate. Because of its pharmacologic effects on bone metabolism, strontium ranelate significantly reduced tooth movement and root resorption in orthodontic treatment of rats. Strontium ranelate may be a viable agent for inducing tooth anchorage and reducing undesired root resorption in orthodontic treatment. Patients under medication of strontium ranelate have to expect prolonged orthodontic treatment times. Copyright © 2014 Elsevier B.V. All rights reserved.

  7. Verification of the local structural response of building structures in the anchorage areas of heavy components

    International Nuclear Information System (INIS)

    Krutzik, N.J.; Tropp, R.

    1989-01-01

    In conventional dynamic structural analyses for determining dynamic system response for various locations at which components are installed inside the structures it is common practice (in order to simplify analytical effort) to assume that the anchorage (anchor plate, anchor bolts or throughbolts, concrete and reinforcement in the area of bound) has rigid body characteristics and that the building structure itself does not display any local response of its own. The influence of the stiffness of the anchor plate as well anchor bolts and its stress level on the dynamic response is also neglected. For a large number of anchoring systems, especially for all those components and systems having only a small mass, this assumption is certainly appropriate. At some locations, particularly at points where heavy components are anchored or when loading input has been increased, this can lead to local loading of the anchor system as well as of the building structure well into the nonlinear range. Often, verification of capability to accommodate these loads is not possible without changing the wall thicknesses or increasing the percentage of reinforcement. Since the presence of linear or nonlinear effects can be expected to result in energy dissipation (increase in damping capacity and also a change in the stiffness of the coupled system) it must be assumed that the dynamic response between the theoretical coupling point A and the real connection point B of the component on the anchor plate can be considerably altered. Some changes of the dynamic response in the connection point B have to be expected generally even in cases of linear-elastic loading of the anchorage. Using typical anchoring systems as an example, the influence of consideration of nonlinear effects in the anchorage area of a typical anchor plate on the dynamic response as well as the conservatism of conventional analytical approaches are investigated

  8. Randomized clinical trial comparing control of maxillary anchorage with 2 retraction techniques.

    Science.gov (United States)

    Xu, Tian-Min; Zhang, Xiaoyun; Oh, Hee Soo; Boyd, Robert L; Korn, Edward L; Baumrind, Sheldon

    2010-11-01

    The objective of this pilot randomized clinical trial was to investigate the relative effectiveness of anchorage conservation of en-masse and 2-step retraction techniques during maximum anchorage treatment in patients with Angle Class I and Class II malocclusions. Sixty-four growing subjects (25 boys, 39 girls; 10.2-15.9 years old) who required maximum anchorage were randomized to 2 treatment techniques: en-masse retraction (n = 32) and 2-step retraction (n = 32); the groups were stratified by sex and starting age. Each patient was treated by a full-time clinic instructor experienced in the use of both retraction techniques at the orthodontic clinic of Peking University School of Stomatology in China. All patients used headgear, and most had transpalatal appliances. Lateral cephalograms taken before treatment and at the end of treatment were used to evaluate treatment-associated changes. Differences in maxillary molar mesial displacement and maxillary incisor retraction were measured with the before and after treatment tracings superimposed on the anatomic best fit of the palatal structures. Differences in mesial displacement of the maxillary first molar were compared between the 2 treatment techniques, between sexes, and between different starting-age groups. Average mesial displacement of the maxillary first molar was slightly less in the en-masse group than in the 2-step group (mean, -0.36 mm; 95% CI, -1.42 to 0.71 mm). The average mesial displacement of the maxillary first molar for both treatment groups pooled (n = 63, because 1 patient was lost to follow-up) was 4.3 ± 2.1 mm (mean ± standard deviation). Boys had significantly more mesial displacement than girls (mean difference, 1.3 mm; P <0.03). Younger adolescents had significantly more mesial displacement than older adolescents (mean difference, 1.3 mm; P <0.02). Average mesial displacement of the maxillary first molar with 2-step retraction was slightly greater than that for en-masse retraction, but the

  9. Dental extrusion with orthodontic miniscrew anchorage: a case report describing a modified method.

    Science.gov (United States)

    Horliana, Ricardo Fidos; Horliana, Anna Carolina Ratto Tempestini; Wuo, Alexandre do Vale; Perez, Flávio Eduardo Guillin; Abrão, Jorge

    2015-01-01

    In recent years, the skeletal anchorage through miniscrews has expanded the treatment options in orthodontics (Yamaguchi et al., 2012). We hereby present a modified method for tooth extrusion for cases where crown-lengthening surgery is contraindicated for aesthetic reasons. This modified method uses three orthodontic appliances: a mini-implant, an orthodontic wire, and a bracket. The aim of this case report was to increase the length of the clinical crown of a fractured tooth (tooth 23) by means of an orthodontic extrusion with the modified method of Roth and Diedrich.

  10. Ground-water quality beneath solid-waste disposal sites at anchorage, Alaska

    Science.gov (United States)

    Zenone, Chester; Donaldson, D.E.; Grunwaldt, J.J.

    1975-01-01

    Studies at three solid-waste disposal sites in the Anchorage area suggest that differences in local geohydrologic conditions influence ground-water quality. A leachate was detected in ground water within and beneath two sites where the water table is very near land surface and refuse is deposited either at or below the water table in some parts of the filled areas. No leachate was detected in ground water beneath a third site where waste disposal is well above the local water table.

  11. A study on setting of the fatigue limit of temporary dental implants.

    Science.gov (United States)

    Kim, M H; Cho, E J; Lee, J W; Kim, E K; Yoo, S H; Park, C W

    2017-07-01

    A temporary dental implant is a medical device which is temporarily used to support a prosthesis such as an artificial tooth used for restoring patient's masticatory function during implant treatment. It is implanted in the oral cavity to substitute for the role of tooth. Due to the aging and westernization of current Korean society, the number of tooth extraction and implantation procedures is increasing, leading to an increase in the use and development of temporary dental implants. Because an implant performs a masticatory function in place of a tooth, a dynamic load is repeatedly put on the implant. Thus, the fatigue of implants is reported to be the most common causes of the fracture thereof. According to the investigation and analysis of the current domestic and international standards, the standard for fatigue of implant fixtures is not separately specified. Although a test method for measuring the fatigue is suggested in an ISO standard, it is a standard for permanent dental implants. Most of the test standards for Korean manufacturers and importers apply 250 N or more based on the guidance for the safety and performance evaluation of dental implants. Therefore, this study is intended to figure out the fatigue standard which can be applied to temporary dental implants when measuring the fatigue according to the test method suggested in the permanent dental implant standard. The results determined that suitable fatigue standards of temporary dental implants should be provided by each manufacturer rather than applying 250 N. This study will be useful for the establishment of the fatigue standards and fatigue test methods of the manufacturers and importers of temporary dental implants.

  12. Tocopherol in irradiation of temporary hypoxic tumours

    International Nuclear Information System (INIS)

    Kaagerud, A.; Lund, N.; Peterson, H.I.

    1981-01-01

    The influence of tocopherol on the effect of local irradiation under induced ischaemia by temporary tourniquet of two rat tumours transplanted intramuscularly into one hindleg was evaluated. An impaired retardation of growth rate occurred in tumours irradiated under ischaemia. This effect was eliminated by pretreatment of animals with tocopherol. In separate experiments the method of inducing ischaemia was investigated by MDO-electrode measurements of tumour tissue oxygen pressure. A significant tumour hypoxia was found under tourniquet of the tumour-bearing leg of the animals. Pretreatment with tocopherol did not influence the tumour pO 2 . (Auth.)

  13. Temporary effects of alcohol on color vision

    Science.gov (United States)

    Geniusz, Maciej K.; Geniusz, Malwina; Szmigiel, Marta; Przeździecka-Dołyk, Joanna

    2017-09-01

    The color vision has been described as one to be very sensitive to the intake of several chemicals. The present research reviews the published literature that is concerned with color vision impairment due to alcohol. Most of this research considers people under long-term effects of alcohol. However, there is little information about temporary effects of alcohol on color vision. A group of ten volunteers aged 18-40 was studied. During the study levels of alcohol in the body were tested with a standard breathalyzer while color vision were studied using Farnsworth Munsell 100 Hue Color Vision Tests. Keywords: Col

  14. Temporary new opening hours for Gate C

    CERN Multimedia

    GS Department

    2010-01-01

    Please note the new temporary opening hours for the gate C as from 22 September 2010 until 29 October 2010 (working days): Morning: between 7:00 a.m. and 9:00 a.m. Lunch: between 12:00 and 2:00 p.m. Evening: between 5:00 pm and 7:00 p.m. Traffic flow will be permitted in both directions during this period. Please minimize your speed accordingly and respect all road signs. GS-SEM Group General Infrastructure Services Department

  15. Temporary provision against Kernkraftwerk Biblis dismissed

    International Nuclear Information System (INIS)

    Anon.

    1980-01-01

    With its decision of November 19, 1979 - VIII IG 13/79 -, the Administrative Court of Hesse has refused the complaint of a Darmstadt resident whose application for a temporary provision interdicting further operation of the power plant units Biblis A and B had been refused by the Darmstadt Administrative Court. The costs of the procedure, including the extra-judicial costs of the witnesses heard, are to be paid by the plaintiff. The value in litigation was raised to DM 10 000,-. (orig./HP) 891 HP/orig.- 892 CKA [de

  16. Local hypertrichosis: A rare complication of a temporary henna tattoo.

    Science.gov (United States)

    Akpolat, Nebahat Demet; Aras, Arzu

    2016-01-01

    Temporary henna tattoos have become increasingly widespread among children and young people, especially in holiday spots in recent years. Although reactions to henna tattoo are becoming progressively more common, only few cases of a henna pseudo-tattoo resulting in temporary hypertrichosis have been reported so far. Here, we have reported a 5-year-old girl who developed allergic contact dermatitis and localized hypertrichosis on her right arm after application of temporary henna tattoo during summer holiday.

  17. Morbidity with temporary disability in Kozloduy NPP workers

    International Nuclear Information System (INIS)

    Dobreva, B.; Novkirishki, V.

    1993-01-01

    Changes with time in indicators of disease incidence with temporary disability in Kozloduy NPP personnel have been studied for the period 1974-1991. The data were compared with those for 'Sofia-Iztok' TPP. The causes contributing to formation of the indicators of frequency, severity, and average duration were examined. No temporary disability because of radiation exposure has been recorded. As a whole, less temporary disability has been found at NPP than at TPP. (author)

  18. Bioreactor design for successive culture of anchorage-dependent cells operated in an automated manner.

    Science.gov (United States)

    Kino-Oka, Masahiro; Ogawa, Natsuki; Umegaki, Ryota; Taya, Masahito

    2005-01-01

    A novel bioreactor system was designed to perform a series of batchwise cultures of anchorage-dependent cells by means of automated operations of medium change and passage for cell transfer. The experimental data on contamination frequency ensured the biological cleanliness in the bioreactor system, which facilitated the operations in a closed environment, as compared with that in flask culture system with manual handlings. In addition, the tools for growth prediction (based on growth kinetics) and real-time growth monitoring by measurement of medium components (based on small-volume analyzing machinery) were installed into the bioreactor system to schedule the operations of medium change and passage and to confirm that culture proceeds as scheduled, respectively. The successive culture of anchorage-dependent cells was conducted with the bioreactor running in an automated way. The automated bioreactor gave a successful culture performance with fair accordance to preset scheduling based on the information in the latest subculture, realizing 79- fold cell expansion for 169 h. In addition, the correlation factor between experimental data and scheduled values through the bioreactor performance was 0.998. It was concluded that the proposed bioreactor with the integration of the prediction and monitoring tools could offer a feasible system for the manufacturing process of cultured tissue products.

  19. Prestressed CFRP Strips with Gradient Anchorage for Structural Concrete Retrofitting: Experiments and Numerical Modeling

    Directory of Open Access Journals (Sweden)

    Julien Michels

    2014-01-01

    Full Text Available This paper presents a study on the load carrying capacity of reinforced concrete (RC beams strengthened with externally bonded (EB carbon fiber reinforced polymer (CFRP strips prestressed up to 0.6% in strain. At the strip ends, the innovative gradient anchorage is used instead of conventional mechanical fasteners. This method, based on the epoxy resin’s ability to rapidly cure under high temperatures, foresees a sector-wise heating followed by a gradual decrease of the initial prestress force towards the strip ends. The experimental investigation shows a promising structural behavior, resulting in high strip tensile strains, eventually almost reaching tensile failure of the composite strip. Additionally, ductility when considering deflection at steel yielding and at ultimate load is satisfying, too. From a practical point of view, it is demonstrated that premature strip grinding in the anchorage zone is not beneficial. In addition, a non-commercial 1D finite element code has been enlarged to an EB reinforcement with prestressed composite strips. A bilinear bond stress-slip relation obtained in earlier investigations is introduced as an additional failure criterion to the code. The numerical code is able to almost perfectly predict the overall structural behavior. Furthermore, the calculations are used for comparison purposes between an initially unstressed and a prestressed externally bonded composite reinforcement. The increase in cracking and yielding load, as well as differences in structural stiffness are apparent.

  20. [Treatment of adult bimaxillary arch protrusion with micro-implant anchorage].

    Science.gov (United States)

    Chen, Cheng; Zhang, Xiao-Rong

    2015-02-01

    In this study, micro-implants were used in 15 adult patients with mild and moderate bimaxillary arch protrusion or crowding. Cephalometric analysis was used to analyze hard and soft-tissues change before and after treatment, with the aim to investigate the effects of treatment on adult bimaxillary arch protrusion with micro-implant anchorage. Fifteen adult patients with mild and moderate bimaxillary arch protrusion were selected in this study. Micro-implants were inserted into the zygomaticoalveolar ridge of maxilla and the external oblique line of mandible. A NiTi coil spring was attached to the micro-implant to drag the whole upper and lower dentition for distal movement. Cephalometrics were taken before and after treatment, and the changes of soft and hard-tissue profile were studied. SPSS13.0 software package was used to analyze the data. (1)Sixty micro-implants remained stable.(2)SNA, SNB had no significant changes (P>0.05), and the relationship between the maxilla and the mandible did not change significantly. U1/NA, U1-NA, L1/NB, L1-NB and U1/L1 changes in hard tissue had significant difference in cephalometric measurement (PMicro-implant can provide not only excellent skeletal anchorage but also a novel way to distalize the whole dentition efficiently.

  1. Verification of the local structural response of building structures in the anchorage areas of heavy components

    International Nuclear Information System (INIS)

    Krutzik, N.J.; Tropp, R.

    1993-01-01

    In both nuclear and non-nuclear areas of power plants, sections of structures, parts of systems and components are attached to walls and floors by means of anchor plates with bolts, anchor sleeves and bolts and through bolts arranged either in groups or individually. In order to simplify the determination of the transfered vibrations induced by external events (e.g. earthquake, aircraft crash), it is normally assumed that the nodal point between component and concrete possesses rigid body characteristics and the building structure (walls, floors) is also inflexible in the anchorage area. In the course of the parametric studies performed, the nonlinear effects on the anchorage area of a component (in this case an anchor plate and concrete slab) were calculated and the effect of these on the actual vibration behavior and the local structural responses of the building structure at the place of installation of heavy components were investigated. The investigations performed reveal that by taking into account the local behaviour in the anchoring point, it is possible to reduce the dynamic response considerably. More detailed examination of the influence of additional parameters (especially of the geometry of the anchor plates and anchor bolts and their material characteristics) will require further investigations aimed at establishing the characteristics of typical anchor plates. (orig.)

  2. Design of steel-liners and their anchorage with regard to non-linear behaviour of liner-material and anchorage

    International Nuclear Information System (INIS)

    Oberpichler, R.

    1979-01-01

    The thin steel liner attached by studs or rib-type anchors to the interior wall of a Prestressed Concrete Reactor Pressure Vessel (PCRV) or a Concrete Containment Vessel (PCCV) has to provide the leak-tightness of the vessel. The liner also may serve as internal shuttering for placing concrete as well as a support for the cooling system or thermal isolation. Mainly strained by self-limited loads imposed on the liner by deformations of the vessel-wall or by heatup inside the vessel the liner predominantly will function in a compressive biaxially strained state like a membrane. The vessel-wall is assumed to be a rigid boundary without reactions caused by the liner-anchor-restraints. Furthermore it is assumed that the liner supported in a close-spaced pattern to the concrete with respect to self-limited loads and all effects of non-linear behaviour of liner-material and non-linear anchor-characteristics will not fail by instability, especially not by an effect of snapthrough. Only one essential mode of failure, the shear connector failure is assumed to be basis for all liner investigations. Design of the liner and its anchorage therefore is based on the analysis of large deformations with regard to elastic-plastic behaviour of liner-material and non-linear anchor characteristics. By this method both economical and safe sizing and spacing of the anchors can be calculated. (orig.)

  3. Nutrient mitigation in a temporary river basin.

    Science.gov (United States)

    Tzoraki, Ourania; Nikolaidis, Nikolaos P; Cooper, David; Kassotaki, Elissavet

    2014-04-01

    We estimate the nutrient budget in a temporary Mediterranean river basin. We use field monitoring and modelling tools to estimate nutrient sources and transfer in both high and low flow conditions. Inverse modelling by the help of PHREEQC model validated the hypothesis of a losing stream during the dry period. Soil and Water Assessment Tool model captured the water quality of the basin. The 'total daily maximum load' approach is used to estimate the nutrient flux status by flow class, indicating that almost 60% of the river network fails to meet nitrogen criteria and 50% phosphate criteria. We recommend that existing well-documented remediation measures such as reforestation of the riparian area or composting of food process biosolids should be implemented to achieve load reduction in close conjunction with social needs.

  4. Temporary Immersion System for Date Palm Micropropagation.

    Science.gov (United States)

    Othmani, Ahmed; Bayoudh, Chokri; Sellemi, Amel; Drira, Noureddine

    2017-01-01

    The temporary immersion system (TIS) is being used with tremendous success for automation of micropropagation of many plant species. TIS usually consists of a culture vessel comprising two compartments, an upper one with the plant material and a lower one with the liquid culture medium and an automated air pump. The latter enables contact between all parts of the explants and the liquid medium by setting overpressure to the lower part of the container. These systems are providing the most satisfactory conditions for date palm regeneration via shoot organogenesis and allow a significant increase of multiplication rate (5.5-fold in comparison with that regenerated on agar-solidified medium) and plant material quality, thereby reducing production cost.

  5. Temporary fire sealing of penetrations on TFTR

    International Nuclear Information System (INIS)

    Hondorp, H.L.

    1981-02-01

    The radiation shielding provided for TFTR for D-D and D-T operation will be penetrated by numerous electrical and mechanical services. Eventually, these penetrations will have to be sealed to provide the required fire resistance, tritium sealability, pressure integrity and radiation attenuation. For the initial hydrogen operation, however, fire sealing of the penetrations in the walls and floor is the primary concern. This report provides a discussion of the required and desirable properties of a temporary seal which can be used to seal these penetrations for the hydrogen operation and then subsequently be removed and replaced as required for the D-D and D-T operations. Several candidate designs are discussed and evaluated and recommendations are made for specific applications

  6. 26 CFR 20.2032-1T - Alternate valuation (temporary).

    Science.gov (United States)

    2010-04-01

    ...) the value of the property as of the alternate valuation date. For example, assume that the decedent... 26 Internal Revenue 14 2010-04-01 2010-04-01 false Alternate valuation (temporary). 20.2032-1T...-1T Alternate valuation (temporary). (a) through (e) [Reserved] For further guidance, see § 20.2032-1...

  7. 19 CFR 210.77 - Temporary emergency action.

    Science.gov (United States)

    2010-04-01

    ... 19 Customs Duties 3 2010-04-01 2010-04-01 false Temporary emergency action. 210.77 Section 210.77 Customs Duties UNITED STATES INTERNATIONAL TRADE COMMISSION INVESTIGATIONS OF UNFAIR PRACTICES IN IMPORT TRADE ADJUDICATION AND ENFORCEMENT Enforcement Procedures and Advisory Opinions § 210.77 Temporary...

  8. 19 CFR 210.68 - Complainant's temporary relief bond.

    Science.gov (United States)

    2010-04-01

    ... Section 210.68 Customs Duties UNITED STATES INTERNATIONAL TRADE COMMISSION INVESTIGATIONS OF UNFAIR PRACTICES IN IMPORT TRADE ADJUDICATION AND ENFORCEMENT Temporary Relief § 210.68 Complainant's temporary... by Individual Surety United States International Trade Commission Affidavit by Individual Surety 19...

  9. 20 CFR 416.1167 - Temporary absences and deeming rules.

    Science.gov (United States)

    2010-04-01

    ... FOR THE AGED, BLIND, AND DISABLED Income Deeming of Income § 416.1167 Temporary absences and deeming..., we consider your absence to be temporary through the date of discharge. (b) Child away at school. If you are an eligible child who is away at school but comes home on some weekends or lengthy holidays...

  10. 40 CFR 310.10 - What are temporary emergency measures?

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 27 2010-07-01 2010-07-01 false What are temporary emergency measures... RESPONSE TO HAZARDOUS SUBSTANCE RELEASES Provisions What Can Be Reimbursed? § 310.10 What are temporary... security; (2) Controlling the source of contamination; (3) Containing the release to prevent spreading; (4...

  11. 47 CFR 25.277 - Temporary fixed earth station operations.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 2 2010-10-01 2010-10-01 false Temporary fixed earth station operations. 25.277 Section 25.277 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) COMMON CARRIER SERVICES SATELLITE COMMUNICATIONS Technical Operations § 25.277 Temporary fixed earth station operations...

  12. Impact of a temporary stoma on patients' everyday lives

    DEFF Research Database (Denmark)

    Danielsen, Anne K; Soerensen, Erik E; Burcharth, Kirsten

    2013-01-01

    AIMS AND OBJECTIVES: To examine patients' experiences of impact of a temporary stoma on their everyday life. Furthermore, we wanted to generate new knowledge and comprehension of learning how to live with a temporary stoma. BACKGROUND: There are many aspects, largely unexplored, that may influenc...

  13. Temporary and Travelling Exhibitions. Museums and Monuments, X.

    Science.gov (United States)

    Daifuku, Hiroshi; And Others

    The permanent exhibition, the most typical form of museum exhibition, has failed to attract repeated visitation, since visitors quickly become familiar with the objects shown. The temporary exhibition evolved as a result for the need of repeated visitation. The temporary exhibition, set up for a period of one to six months, introduces fresh…

  14. 26 CFR 1.846-4T - Effective dates (temporary).

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 8 2010-04-01 2010-04-01 false Effective dates (temporary). 1.846-4T Section 1.846-4T Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES Other Insurance Companies § 1.846-4T Effective dates (temporary). (a) [Reserved...

  15. 17 CFR 256.136 - Temporary cash investments.

    Science.gov (United States)

    2010-04-01

    ... 17 Commodity and Securities Exchanges 3 2010-04-01 2010-04-01 false Temporary cash investments... UTILITY HOLDING COMPANY ACT OF 1935 3. Current and Accrued Assets § 256.136 Temporary cash investments. This account shall include the cost of investments, such as demand and time loans, bankers' acceptances...

  16. 78 FR 11745 - Anchorages; Lower Mississippi River, Above Head of Passes, Convent, LA and Point Pleasant, LA

    Science.gov (United States)

    2013-02-20

    ... able to maneuver in, around, and through the anchorage. Operators who choose to maneuver their vessels... respects the First Amendment rights of protesters. Protesters are asked to contact the person listed in the FOR FURTHER INTFORMATION CONTACT section to coordinate protest activities so that your message can be...

  17. 33 CFR 110.236 - Pacific Ocean off Barbers Point, Island of Oahu, Hawaii: Offshore pipeline terminal anchorages.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Pacific Ocean off Barbers Point... Grounds § 110.236 Pacific Ocean off Barbers Point, Island of Oahu, Hawaii: Offshore pipeline terminal... regulations. (1) No vessels may anchor, moor, or navigate in anchorages A, B, C, or D except: (i) Vessels...

  18. Factors affecting closure of a temporary stoma.

    Science.gov (United States)

    Taylor, Claire; Varma, Sarah

    2012-01-01

    The purpose of the study was to examine time to reversal of a temporary ostomy, reasons for delayed closure, and patient satisfaction with the scheduling of their closure and related hospital care. Cross-sectional, descriptive study. The target population comprised patients who underwent creation of a temporary ostomy and reversal surgery within one National Health System Hospital Trust in the United Kingdom. The population served by this Trust are ethnically and socioeconomically diverse, predominantly living in urban areas around Greater London. Sixty-one persons who met inclusion criteria were identified. A two-step analytical process was undertaken. First, a literature review examining incidence and causes of delayed stoma closure was undertaken. Second, a postal survey of all patients who had had their stoma closed in 2009 was conducted. Respondents were allowed 2 weeks to complete and return the questionnaire. The survey instrument was developed locally and subjected to content validation using ostomy patients, surgical and nursing colleagues. It consisted of 9 questions querying time from original surgery to closure, reasons for delaying closure surgery beyond 12 weeks, and satisfaction with care. Twenty-seven patients returned their questionnaires, indicating they consented to participate; a response rate of 44%. Half of the respondents (n = 14 [52%]) underwent closure surgery within 6 months of stoma formation; the remaining 48% waited more than 6 months (median: 6.5 months, range: 1.5-26 months). Thirteen patients (48%) reported a delay in receiving their stoma closure; the main reason cited was the need for a course of adjuvant postoperative chemotherapy. Three quarters of respondents (22 [74%]) were satisfied with the overall care they received. Findings from this study suggest that stoma closure may be associated with fewest complications if performed before 12 weeks.

  19. Schedules of Controlled Substances: Temporary Placement of 4-Fluoroisobutyryl Fentanyl into Schedule I. Temporary scheduling order.

    Science.gov (United States)

    2017-05-03

    The Administrator of the Drug Enforcement Administration is issuing this temporary scheduling order to schedule the synthetic opioid, N-(4-fluorophenyl)-N-(1-phenethylpiperidin-4-yl)isobutyramide (4-fluoroisobutyryl fentanyl or para-fluoroisobutyryl fentanyl), and its isomers, esters, ethers, salts and salts of isomers, esters, and ethers, into schedule I pursuant to the temporary scheduling provisions of the Controlled Substances Act. This action is based on a finding by the Administrator that the placement of 4-fluoroisobutyryl fentanyl into schedule I of the Controlled Substances Act is necessary to avoid an imminent hazard to the public safety. As a result of this order, the regulatory controls and administrative, civil, and criminal sanctions applicable to schedule I controlled substances will be imposed on persons who handle (manufacture, distribute, reverse distribute, import, export, engage in research, conduct instructional activities or chemical analysis, or possess), or propose to handle, 4-fluoroisobutyryl fentanyl.

  20. 32 CFR 147.31 - Temporary eligibility for access at the top secret levels and temporary eligibility for “Q...

    Science.gov (United States)

    2010-07-01

    ... Guidelines for Temporary Access § 147.31 Temporary eligibility for access at the top secret levels and... 32 National Defense 1 2010-07-01 2010-07-01 false Temporary eligibility for access at the top secret levels and temporary eligibility for âQâ access authorization: For someone who is the subject of a...

  1. Temporary Employment and the Future Labor Market Status

    Directory of Open Access Journals (Sweden)

    Tomas Berglund

    2017-06-01

    Full Text Available The aim of this article is to describe and explain the development of temporary employment in Sweden between 1992 and 2010, and to investigate the effect of temporary employment for individuals’ future career on the labor market. The article analyzes temporary employees’ status transitions on the labor market using Swedish Labour Force Survey (LFS data for the period 1992–2010. Each cohort consists of 2-year panels and focuses on changes between the first and last measuring points. The findings indicate that the specific type of temporary employment is crucial as regards whether or not it constitutes a stepping-stone toward permanent employment. The chances are greater in the case of, for example, substitutes, but are considerably less in the case of on-call employment. Certain types of temporary employment thus seem to be used by the employer to screen the employability of the employee, while others are used for achieving flexibility

  2. 78 FR 44965 - Notice of Temporary Closure and Temporary Restrictions of Specific Uses on Public Lands for the...

    Science.gov (United States)

    2013-07-25

    ... individual during normal business hours. The FIRS is available 24 hours a day, 7 days a week, to leave a... provide law enforcement officers to work at the event. The temporary closure and temporary restrictions...) Weapon means a firearm, compressed gas or spring powered pistol or rifle, bow and arrow, cross bow...

  3. 76 FR 37147 - Notice of Temporary Closures and Temporary Restrictions on Specific Uses of Public Lands in...

    Science.gov (United States)

    2011-06-24

    ... days a week, to leave a message or question with the above individual. You will receive a reply during... provide additional law enforcement officers to work at the event. These temporary closures and temporary... authorized officer. 4. Definitions: (a) Weapon means a firearm, compressed gas or spring powered pistol or...

  4. 77 FR 63835 - Office of the Chief Information Officer; Submission for OMB Review; Temporary Contractor...

    Science.gov (United States)

    2012-10-17

    ... of the Chief Information Officer; Submission for OMB Review; Temporary Contractor Information... information collection requirement regarding temporary contractor information worksheet. A notice was... for temporary contractors as a result of the American Recovery and Reinvestment Act of 2009 (Public...

  5. Temporary Vascular Occlusion by Rapid Reverse Phase Polymer: A Preliminary In Vitro Study of Retrograde Injection

    Directory of Open Access Journals (Sweden)

    Einar Dregelid

    2012-01-01

    Full Text Available During vascular surgical operations, there is a need for a simpler and more reliable method of temporary arterial occlusion than those currently employed, especially of heavily calcified arteries. A thermosensitive polymer, LeGoo (LG (Pluromed, Woburn, MA, has been used successfully for temporary vascular occlusion. It has hitherto been injected by a cannula that has been introduced into the artery to be occluded, here henceforth called the “cannulation method.” Injection into arterial ostia without cannulation, using an injection device that arrests blood flow during the injection, here henceforth called “a retrograde method” may enable temporary hemostasis when ostial stenoses render it impossible to inject LG using the cannulation method. The objective of the present study was to study the feasibility of a retrograde method and to compare it with the cannulation method in an in vitro model, incorporating a narrow orifice to simulate ostial stenosis, using tap water at 37°C instead of blood. The retrograde method of LG injection, using a modified paediatric Foley catheter, turned out to be feasible to produce a durable LG plug more reliably, at higher water pressure and with less deep LG injection than with the cannulation method.

  6. Orthodontic retreatment using anchorage with miniplate to camouflage a Class III skeletal pattern.

    Science.gov (United States)

    Farret, Marcel Marchiori

    2016-06-01

    This manuscript describes the treatment of a 27-year-old patient who was previously treated with two maxillary first premolar extractions. The patient had skeletal Class III malocclusion, Class III canine relationship, anterior crossbite, and a concave profile. As the patient refused orthognathic surgery, a miniplate was used on the right side of the lower arch as an anchorage unit after the extraction of mandibular first premolars, aiding the retraction of anterior teeth. At the end of treatment, anterior crossbite was corrected, in which first molars and canines were in a Class I relationship, and an excellent intercuspation was reached. Furthermore, patient's profile remarkably improved as a result of mandibular incisor retraction. A 30-month follow-up showed good stability of the results obtained. This case was presented to the Brazilian Board of Orthodontics and Dentofacial Orthopedics (BBO) as one of the requirements to become diplomate by the BBO.

  7. Association of ultraviolet-induced retrovirus expression with anchorage-independent survival in rat embryo cells

    International Nuclear Information System (INIS)

    Suk, W.A.

    1985-01-01

    The authors have shown in the AI assay that the nontransforming retrovirus increases the differential in enhanced survival response in infected cultures. To more fully understand this aspect of the system, they examined the effect of UV irradiation on infected and uninfected FRE cells. In this communication the authors report that UV irradiation induces AI survival in infected and uninfected cells;in uninfected cells there is a concomitant induction of endogenous retrovirus expression. The AI survival of both cell lines was determined using a previously described procedure. Anchorage-dependent media control and solvent control cells, when suspended in medium above an agar base layer, showed a rapid decline in cell survival;however, cells that had been treated with carcinogen did not undergo the destructive process that took place in control cells, indicating specificity

  8. Orthodontic retreatment using anchorage with miniplate to camouflage a Class III skeletal pattern

    Directory of Open Access Journals (Sweden)

    Marcel Marchiori Farret

    Full Text Available ABSTRACT This manuscript describes the treatment of a 27-year-old patient who was previously treated with two maxillary first premolar extractions. The patient had skeletal Class III malocclusion, Class III canine relationship, anterior crossbite, and a concave profile. As the patient refused orthognathic surgery, a miniplate was used on the right side of the lower arch as an anchorage unit after the extraction of mandibular first premolars, aiding the retraction of anterior teeth. At the end of treatment, anterior crossbite was corrected, in which first molars and canines were in a Class I relationship, and an excellent intercuspation was reached. Furthermore, patient's profile remarkably improved as a result of mandibular incisor retraction. A 30-month follow-up showed good stability of the results obtained. This case was presented to the Brazilian Board of Orthodontics and Dentofacial Orthopedics (BBO as one of the requirements to become diplomate by the BBO.

  9. Permanent and temporary pacemaker implantation after orthotopic heart transplantation

    Directory of Open Access Journals (Sweden)

    Bacal Fernando

    2000-01-01

    Full Text Available PURPOSE:To determine the indication for and incidence and evolution of temporary and permanent pacemaker implantation in cardiac transplant recipients. METHODS: A retrospective review of 114 patients who underwent orthotopic heart transplantation InCor (Heart Institute USP BR between March 1985 and May 1993. We studied the incidence of and indication for temporary pacing, the relationship between pacing and rejection, the need for pemanent pacing and the clinical follow-up. RESULTS: Fourteen of 114 (12%heart transplant recipients required temporary pacing and 4 of 114 (3.5% patients required permanent pacing. The indication for temporary pacing was sinus node dysfunction in 11 patients (78.5% and atrioventricular (AV block in 3 patients (21.4%. The indication for permanent pacemaker implantation was sinus node dysfunction in 3 patients (75% and atrioventricular (AV block in 1 patient (25%. We observed rejection in 3 patients (21.4% who required temporary pacing and in 2 patients (50% who required permanent pacing. The previous use of amiodarone was observed in 10 patients (71.4% with temporary pacing. Seven of the 14 patients (50% died during follow-up. CONCLUSION: Sinus node dysfunction was the principal indication for temporary and permanent pacemaker implantation in cardiac transplant recipients. The need for pacing was related to worse prognosis after cardiac transplantation.

  10. Corrosion and Corrosion-Assisted Cracking of a Magnesium Alloy under Appropriate Mechano-Chemical Conditions for Temporary Bioimplant Applications

    OpenAIRE

    Harandi, Shervin Eslami

    2017-01-01

    In the recent years, magnesium (Mg) and its alloys have attracted great research interest as temporary implants devices such as screws, wires, plates and stents, as they possess one of the best biocompatibilities, and their degradation products are not at all harmful to human physiology. In addition, Mg has the required mechanical strength as well as its density and elastic modulus are respectively close to those of natural bone which result in alleviation of the stress s...

  11. Return to Work After Temporary Disability Pension in Finland.

    Science.gov (United States)

    Laaksonen, Mikko; Gould, Raija

    2015-09-01

    When it is possible that the employee's work ability can be restored through treatment or rehabilitation, disability pension in Finland is granted for a fixed period. We examined which factors are associated with return to work (RTW) after such temporary disability pension. The study included all Finnish residents whose temporary disability pension from the earnings-related pension system started in 2008 (N = 10,269). Competing risks regression analysis was applied to examine register-based determinants for RTW after temporary disability pension due to mental disorders, musculoskeletal diseases, other diseases, and injury over a 4-year follow-up period. The overall cumulative incidence of RTW was 25%. RTW was more probable after temporary disability pension due to injury and musculoskeletal diseases and less probable after temporary disability pension due to mental disorders. Younger age and higher education increased RTW but differences between genders, private and public sector employees, and occupational classes were relatively small. The probability of RTW was higher among those who were employed before their temporary disability pension (subhazard ratio in multivariate analysis 2.41 (95% CI 2.13-2.72) and among the 9% who participated in vocational rehabilitation during their pension [SHR 2.10 (95% CI 1.90-2.31)]. With some exceptions, the results were fairly similar for all diagnostic causes of temporary disability pension. Return to work after temporary disability pension was relatively uncommon. Nevertheless, in all diagnostic groups RTW continued for the whole follow-up period. The low educated and those not employed before temporary disability pension need more support in their RTW. The strong association between vocational rehabilitation and RTW suggests that increasing rehabilitation among those with impaired work ability may promote RTW.

  12. Temporary intestinal ischemia for radiation protection

    International Nuclear Information System (INIS)

    Lote, K.

    1983-01-01

    The most important determinant of cellular radiosensivity is the tissue oxygen content at the time of irradiation. The purpose of the present experimental work was to assess a new iscemia-inducing method in order to reduce normal tissue radiation damage during radiotherapy. Temporary ischemia was induced in a cat small intestine by degraded starch microspheres. Regional arterial and tissue blod flow immediately fell by 85% with subsequent normalization within 26 minutes after microsphere injection. No tendency of small vessel thrombosis caused by starch sphere embolization in combination with previous or current intestinal irradiation was detected. Starch sphere remenants were rapidly engulfed by, and persisted within tissue macrophages for 14 days without causing intestinal inflammatory reactions. In vitro studies showed that human platelets neither adhered to nor were aggregated by starch microspheres. The new method, wich occlude arteriolar vessels distal to the mesentric arterial arcades and thus largely excludes collateral blood flow, seems suited to provide effictive and selective feline small intestinal hypoxic radiation protection. This conclusion may also be valid in man

  13. ESDRED Temporary Sealing Technology Final Technical Report

    Energy Technology Data Exchange (ETDEWEB)

    Alonso, J.; Garcia-Sineriz, J. L.; Barcena, I.; Alonso, M. C.; Fernandez Luco, L.; Garcia, J. L.; Fries, T.; Pettersson, S.; Boden, A.; Salo, J. P.

    2009-07-01

    The work in the ESDRED In te grated Project Module 4, Temporary Sealing (using low pH cement) Technology, consisted first of designing a low pH cement formulation and then of preparing several concrete designs suitable for the construction of sealing plugs and for rock support using shot crete techniques. Regarding sealing plugs, a short plug was constructed at Aspo in Sweden and it was very quickly loaded to failure i.e. slippage by applying water pressure to one face. A second, full scale plug was subsequently constructed at Grimsel test site in Switzerland. It was loaded using the swelling pressure created by bentonite blocks which were artificially hydrated. At time of writing the targeted pressure on the plug was not reached. As the saturation of the bentonite is taking longer than expected the partners involved agreed to continue with the saturation of the bentonite blocks and the related data monitoring beyond the ESDRED Project. The studies on low-pH shot crete for rock sup port were based on available recipes of low-pH concrete mixtures for use in a repository. Pilot and full scale tests were carried out in Sweden and in Switzerland. (Author) 5 refs.

  14. Temporary loop ileostomy: prospective study of indications and complication

    International Nuclear Information System (INIS)

    Rajput, A.; Samad, A.; Khanzada, T.W.

    2007-01-01

    To asses the indications and complications of temporary loop ileostomy. This was a prospective cohort study conducted at Isra University Hospital, Hyderabad, Pakistan between February 2003 and August 2006. All patients who had temporary loop ileostomy during that period were included in this study. The indications and various postoperative complications were noted during postoperative hospital stay and subsequently during follow up till stoma were closed. Fifty six patients fulfilled the selection criteria during the study period. Typhoid (enteric) perforation was the most common indication of loop ileostomy accounting for about two thirds of all cases. Other indications were iatrogenic, covering ileostomy for rectal cancers, following resection anastomosis, tuberculosis, blunt abdominal trauma, anastomosis leak and rectovaginal fistula. Post operative skin excoriation was the most common complication while poor siting, transient edema, retraction and high output were other less common complications. Temporary loop ileostomy is the stoma of choice for temporary faecal diversion as most of its complications are manageable conservatively. (author)

  15. 20 CFR 655.21 - Supporting evidence for temporary need.

    Science.gov (United States)

    2010-04-01

    ... Attestations for Temporary Employment in Occupations Other Than Agriculture or Registered Nursing in the United... containing the following: (1) A description of the employer's business history and activities (i.e., primary...

  16. 29 CFR 1601.23 - Preliminary or temporary relief.

    Science.gov (United States)

    2010-07-01

    ..., or political subdivision. (b) In a case involving a government, governmental agency, or political... private individuals from exercising their rights to seek temporary or preliminary relief on their own...

  17. Indications, management, and complications of temporary inferior vena cava filters

    International Nuclear Information System (INIS)

    Linsenmaier, Ulrich; Rieger, Johannes; Schenk, Franz; Rock, Clemens; Mangel, Eugen; Pfeifer, Klaus Juergen

    1998-01-01

    Purpose: We describe the results of a preliminary prospective study using different recently developed temporary and retrievable inferior vena cava (IVC) filters.Methods: Fifty temporary IVC filters (Guenther, Guenther Tulip, Antheor) were inserted in 47 patients when the required period of protection against pulmonary embolism (PE) was estimated to be less than 2 weeks. The indications were documented deep vein thrombosis (DVT) and temporary contraindications for anticoagulation, a high risk for PE, and PE despite DVT prophylaxis.Results: Filters were removed 1-12 days after placement and nine (18%) had captured thrombi. Complications were one PE during and after removal of a filter, two minor filter migrations, and one IVC thrombosis.Conclusion: Temporary filters are effective in trapping clots and protecting against PE, and the complication rate does not exceed that of permanent filters. They are an alternative when protection from PE is required temporarily, and should be considered in patients with a normal life expectancy.

  18. Bio-cultural anchorage of the prickly pear cactus in Tlalnepantla (Morelos, Mexico

    Directory of Open Access Journals (Sweden)

    Torres-Salcido, Gerardo

    2016-06-01

    Full Text Available The prickly pear cactus is a source of food with strong bio-cultural anchorage in Mexico. This is due to at least three factors: 1 the nature and heritage of cacti; 2 cultural heritage; and 3 the socio-cultural relationships with historical and symbolic roots that have facilitated knowledge of how to cultivate it and how to use it. The aim of this article is to put factors of territorial anchorage and its historical transformation in context by examining the case of the municipality of Tlalnepantla in the state of Morelos, Mexico. This community has experienced accelerated change due to the exchange of traditional crops for the prickly pear cactus and the integration of farming, commercialization and agro-transformation. Our hypothesis is that the market, internal conflicts and a lack of socio-institutional coordination have put social organization into crisis, favoring the territorial spread of the prickly pear cactus and making the Local Agro-Food Systems (LAFS of Tlalnepantla less competitive. The conclusions highlight important economic and social advances whose roots lie in the strengthening and anchorage of the territory-product. However, circumstances both internal and external to the community persist, such as intra-community conflicts, the international market and cultural paradigm shifts that affect the producers and put consolidation of the LAFS at risk.El nopal es un alimento con un fuerte anclaje bio-cultural en México, propiciado por al menos tres factores: 1 la naturaleza y el patrimonio de cactáceas; 2 el patrimonio cultural; y, 3 las relaciones socio-culturales que han permitido un “saber hacer” y un “saber utilizar” con raíces históricas y simbólicas. El objetivo es situar los factores de anclaje territorial y su transformación histórica tomando como caso el municipio de Tlalnepantla, en el estado de Morelos, México. Esta comunidad ha experimentado un acelerado cambio por la reconversión de los cultivos

  19. Drying firewood in a temporary solar kiln: a case study.

    Science.gov (United States)

    George R. Sampson; Anthony F. Gasbarro

    1986-01-01

    A pilot study was undertaken to determine drying rates for small diameter, unsplit paper birch firewood that was dried: (1) in a conventional top-covered pile; (2) in a simple, temporary solar kiln; and (3) in tree length. Drying rates were the same for firewood piles whether they were in the temporary solar kilns or only covered on top to keep rain or snow from...

  20. 26 CFR 1.181-5T - Examples (temporary).

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 3 2010-04-01 2010-04-01 false Examples (temporary). 1.181-5T Section 1.181-5T...) INCOME TAXES Itemized Deductions for Individuals and Corporations (continued) § 1.181-5T Examples (temporary). The following examples illustrate the application of §§ 1.181-1T through 1.181-4T: Example 1. X...

  1. Root perforation associated with the use of a miniscrew implant used for orthodontic anchorage: a case report.

    Science.gov (United States)

    McCabe, P; Kavanagh, C

    2012-07-01

    To highlight one of the possible complications associated with the inter-radicular placement of orthodontic miniscrews. This case report describes the endodontic treatment and surgical repair of an iatrogenic root perforation involving a maxillary first molar tooth following the placement of an orthodontic miniscrew placed for anchorage purposes in the treatment of an adult patient. The orthodontic treatment plan was completed. The long-term follow-up shows a successful treatment outcome. Inter-radicular placement of orthodontic miniscrews is a valuable source of anchorage in the treatment of orthodontic patients. Root perforation is a possible complication from inter-radicular placement of orthodontic miniscrews. Root perforation can be successfully treated, but may involve apical surgery. © 2012 International Endodontic Journal.

  2. Operation of Temporary Radioactive waste stoprage facility

    Energy Technology Data Exchange (ETDEWEB)

    Kinseem, A A; Abulfaraj, W H; Sohsah, M A; Kamal, S M; Mamoon, A M [Nuclear Engineering Department, Faculty of Engineering, King Abdelazizi University jeddah-21413, Saudi Arabia (Saudi Arabia)

    1997-12-31

    Radionuclides of various half lives have been in use for several years years at different Departments of king Abdulaziz university, the university hospital, and research center. The use of unsealed radionuclides in many laboratories, resulted in considerable amounts of solid and liquid radwaste, mainly radiopharmaceuticals. To avoid accumulation of radwastes in working areas, a temporary radioactive waste storage facility was built. Segregation of radwastes according to type was carried out, followed by collection into appropriate containers and transfer to the storage facility. Average radiation dose rate inside the store was maintained at about 75 {mu} h{sup -1} through use of appropriate shielding. The dose rates at points one meter outside the store walls were maintained at about 15-20 {mu}Sv h{sup -1}. Utilization of radioisotopes during the period of 1991-1995 resulted in a volume of about 1.8 m{sup 3} of solid radwaste and about 200 L of liquid radwaste. Records of the store inventory are maintained in a computer database, listing dates, types, activities and packaging data pertinent to the radwastes delivered to the store. Quality assurance procedures are implemented during the different stages of the radwaste collection, transportation, and storage. Construction and operation of the storage facility comply with radiation safety requirements for the workers handling the radwastes, the public and the environment. The capacity of the storage facility is such that it will accommodate storage of generated radwastes of long half life up to year 2016. Permanent disposal of such radwastes may be indicated afterwards. 2 figs., 3 tabs.

  3. Early bone anchorage to micro- and nano-topographically complex implant surfaces in hyperglycemia.

    Science.gov (United States)

    Ajami, Elnaz; Bell, Spencer; Liddell, Robert S; Davies, John E

    2016-07-15

    The aim of this work was to investigate the effect of implant surface design on early bone anchorage in the presence of hyperglycemia. 108 Wistar rats were separated into euglycemic (EG) controls and STZ-treated hyperglycemic (HG) groups, and received bilateral femoral custom rectangular implants of two surface topographies: grit blasted (GB) and grit-blast with a superimposed calcium phosphate nanotopography (GB-DCD). The peri-implant bone was subjected to a tensile disruption test 5, 7, and 9days post-operatively (n=28/time point); the force was measured; and the residual peri-implant bone was observed by scanning electron microscopy (SEM). Disruption forces at 5days were not significantly different from zero for the GB implants (p=0.24) in either metabolic group; but were for GB+DCD implants in both metabolic groups (pmicro-surfaced implants showed significantly different disruption forces at all time points (e.g. >15N and implants, as all values were very low (implant bone showed compromised intra-fibrillar collagen mineralization in hyperglycemia, while inter-fibrillar and cement line mineralization remained unaffected. Enhanced bone anchorage to the implant surfaces was observed on the nanotopographically complex surface independent of metabolic group. The compromised intra-fibrillar mineralization observed provides a mechanism by which early bone mineralization is affected in hyperglycemia. It is generally accepted that the hyperglycemia associated with diabetes mellitus compromises bone quality, although the mechanism by which this occurs is unknown. Uncontrolled hyperglycemia is therefore a contra-indication for bone implant placement. It is also known that nano-topographically complex implant surfaces accelerate early peri-implant healing. In this report we show that, in our experimental model, nano-topographically complex surfaces can mitigate the compromised bone healing seen in hyperglycemia. Importantly, we also provide a mechanistic explanation for

  4. [The application of Edgewise technique auxillary with extra oral anchorage and class III elastic in the treatment of bimaxillary protrusion.].

    Science.gov (United States)

    Liu, H H; Weng, S E; Chen, R J

    1995-12-01

    In the treatment of growing bimaxillary protrusion patients,Edgewise technique auxillary with extra oral anchorage and class III elastic help to improve the patient's chin shape,recover his beauty of lower facial part and get a good occlusion along with the growing of mandible.The purpose of this study is:analysis the force system in the treatment and evaluate the result of the treatment with some typical cases.

  5. 48 CFR 37.112 - Government use of private sector temporaries.

    Science.gov (United States)

    2010-10-01

    ... use of private sector temporaries. Contracting officers may enter into contracts with temporary help service firms for the brief or intermittent use of the skills of private sector temporaries. Services... part 300, subpart E, Use of Private Sector Temporaries, and agency procedures. [56 FR 55380, Oct. 25...

  6. Silver oxide-containing hydroxyapatite coating supports osteoblast function and enhances implant anchorage strength in rat femur.

    Science.gov (United States)

    Eto, Shuichi; Miyamoto, Hiroshi; Shobuike, Takeo; Noda, Iwao; Akiyama, Takayuki; Tsukamoto, Masatsugu; Ueno, Masaya; Someya, Shinsuke; Kawano, Shunsuke; Sonohata, Motoki; Mawatari, Masaaki

    2015-09-01

    Antibacterial silver with hydroxyapatite (Ag-HA) is a promising coating material for imparting antibacterial properties to implants. We previously reported that 3% (w/w) silver with HA (3% Ag-HA) has both antibacterial activity and osteoconductivity. In this study, we investigated the effects of Ag-HA on the in vitro osteoblast function and the in vivo anchorage strength and osteoconductivity of implants. Production of the osteoblast marker alkaline phosphatase, but not cytotoxicity, was observed in cells of the osteoblast cell line MC3T3-E1 cultured on the 3% Ag-HA-coated surface. These results were similar to those observed with silver-free HA coating. In contrast, a significant high level of cytotoxicity was observed when the cells were cultured on a 50% Ag-HA-coated surface. The anchorage strength of implants inserted into the femur of Sprague-Dawley (SD) rats was enhanced by coating the implants with 3% Ag-HA. On the 3% Ag-HA-coated surface, both metaphyseal and diaphyseal areas were largely covered with new bone and had adequate osteoconductivity. These results suggest that 3% Ag-HA, like conventional HA, promotes osteogenesis by supporting osteoblast viability and function and thereby contributes to sufficient anchorage strength of implants. Application of 3% Ag-HA, which combines the osteoconductivity of HA and the antibacterial activity of silver, to prosthetic joints will help prevent postoperative infections. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  7. [Comparing the anchorage effects of micro-implant and J hook on treating patients with maxillary protrusion].

    Science.gov (United States)

    Wu, Xin; Liu, Guo-yuan; Jiang, Yong-lian

    2015-10-01

    To investigate the differences in anchorage effects between micro-implants and J hook in treating patients with Class II division 1 maxillary protrusion. Thirty-one cases of adult patients with Class II division 1 maxillary protrusion were treated. They were divided into 2 groups depending on their selection. The first group included 17 patients for micro-implant anchorage, who adopted micro-implant and sliding mechanism to close maxillary extraction space and depress the mandibular molar. The second group encompassed 14 cases for J hook, who adopted sliding mechanism, J hooks in high traction and Class II intermaxillary traction to close extraction space. X-ray lateral cephalometric radiographs were measured before and after treatment, and SPSS16.0 software package was employed to compare the differences in soft and hard tissue changes before and after treatment between 2 groups. There were statistically significant differences in SNB, ANB, MP-FH, U1-Y, U6-Y, L6-MP, NLA, and UL-Y between the 2 groups before and after treatment, while there was no significant difference in SNA, U1-SN, U1-X, and U6-X between the 2 groups. In treating patients with Class II division 1 maxillary protrusion, micro-implant has stronger anchorage effects than J hook, while at the same time depressing the mandibular molars, and making it more favorable to improve Class II faces.

  8. Internal structure of mandible around mandibular molar using computed tomography. Anatomical consideration of molar anchorage in orthodontic treatment

    International Nuclear Information System (INIS)

    Enomoto, Yutaka; Yamashita, Daisuke; Saito, Katsuhiko; Kasai, Kazutaka

    2008-01-01

    For establishment of fine occlusion, facial profile and oral function in orthodontic treatment, molar anchorage in teeth movement is important manner in extracted cases. The aims of this study were to investigate the relationship between facial morphology and internal structure of mandibular body in molar region by computer tomography, and to discuss about molar anchorage in orthodontic treatment. The data for this study were obtained from 35 modern male Japanese skulls (mean age; 27 year-old, ranged from 18 year-old to 47 year-old). Measurement variables were FMA, SN to mandibular plane angle, gonial angle, alveolar breadth, cortical bone thickness of buccal and lingual sides, and the distance between dental root and cortical bone. As a result, alveolar breadth and the distance between dental root and cortical bone were narrow in long facial type, on the contrary, these variables were wide in short facial type. The result suggested that these variables were considered important factors as molar anchorage in extracted cases. (author)

  9. PAX2 regulates ADAM10 expression and mediates anchorage-independent cell growth of melanoma cells.

    Directory of Open Access Journals (Sweden)

    Sophia Boyoung Lee

    Full Text Available PAX transcription factors play an important role during development and carcinogenesis. In this study, we investigated PAX2 protein levels in melanocytes and melanoma cells by Western Blot and immunofluorescence analysis and characterized the role of PAX2 in the pathogenesis of melanoma. In vitro we found weak PAX2 protein expression in keratinocytes and melanocytes. Compared to melanocytes increased PAX2 protein levels were detectable in melanoma cell lines. Interestingly, in tissue sections of melanoma patients nuclear PAX2 expression strongly correlated with nuclear atypia and the degree of prominent nucleoli, indicating an association of PAX2 with a more atypical cellular phenotype. In addition, with chromatin immunoprecipitation assay, PAX2 overexpression and PAX2 siRNA we present compelling evidence that PAX2 can regulate ADAM10 expression, a metalloproteinase known to play important roles in melanoma metastasis. In human tissue samples we found co-expression of PAX2 and ADAM10 in melanocytes of benign nevi and in melanoma cells of patients with malignant melanoma. Importantly, the downregulation of PAX2 by specific siRNA inhibited the anchorage independent cell growth and decreased the migratory and invasive capacity of melanoma cells. Furthermore, the downregulation of PAX2 abrogated the chemoresistance of melanoma cells against cisplatin, indicating that PAX2 expression mediates cell survival and plays important roles during melanoma progression.

  10. Bilateral en-masse distalization of maxillary posterior teeth with skeletal anchorage: a case report

    Directory of Open Access Journals (Sweden)

    Saeed Noorollahian

    Full Text Available ABSTRACT Objective: The aim of this study was to introduce a new method for bilateral distal movement of the entire maxillary posterior segment. Case report: A 17-year-old girl with Class I skeletal malocclusion (end-to-end molar relationships, deviated midline and space deficiency for left maxillary canine was referred for orthodontic treatment. She did not accept maxillary first premolars extraction. A modified Hyrax appliance (Dentaurum Ispringen, Germany was used for bilateral distalization of maxillary posterior teeth simultaneously. Expansion vector was set anteroposteriorly. Posterior legs of Hyrax were welded to first maxillary molar bands. All posterior teeth on each side consolidated with a segment of 0.017 × 0.025-in stainless steel wire from the buccal side. Anterior legs of Hyrax were bent into eyelet form and attached to the anterior palate with two mini-screws (2 × 10 mm (Jeil Medical Corporation Seoul, South Korea. Hyrax opening rate was 0.8 mm per month. Lateral cephalometric radiographs were used to evaluate the extent of distal movement. 3.5-mm distalization of posterior maxillary teeth was achieved in five months. Results: A nearly bodily distal movement without anchorage loss was obtained. Conclusion: The mini-screw-supported modified Hyrax appliance was found to be helpful for achieving en-masse distal movement of maxillary posterior teeth.

  11. Anchorage strength models for end-debonding predictions in RC beams strengthened with FRP composites

    Science.gov (United States)

    Nardini, V.; Guadagnini, M.; Valluzzi, M. R.

    2008-05-01

    The increase in the flexural capacity of RC beams obtained by externally bonding FRP composites to their tension side is often limited by the premature and brittle debonding of the external reinforcement. An in-depth understanding of this complex failure mechanism, however, has not yet been achieved. With specific regard to end-debonding failure modes, extensive experimental observations reported in the literature highlight the important distinction, often neglected in strength models proposed by researchers, between the peel-off and rip-off end-debonding types of failure. The peel-off failure is generally characterized by a failure plane located within the first few millimetres of the concrete cover, whilst the rip-off failure penetrates deeper into the concrete cover and propagates along the tensile steel reinforcement. A new rip-off strength model is described in this paper. The model proposed is based on the Chen and Teng peel-off model and relies upon additional theoretical considerations. The influence of the amount of the internal tensile steel reinforcement and the effective anchorage length of FRP are considered and discussed. The validity of the new model is analyzed further through comparisons with test results, findings of a numerical investigation, and a parametric study. The new rip-off strength model is assessed against a database comprising results from 62 beams tested by various researchers and is shown to yield less conservative results.

  12. Temporary jobs and the severity of workplace accidents.

    Science.gov (United States)

    Picchio, Matteo; van Ours, Jan C

    2017-06-01

    From the point of view of workplace safety, it is important to know whether having a temporary job has an effect on the severity of workplace accidents. We present an empirical analysis on the severity of workplace accidents by type of contract. We used microdata collected by the Italian national institute managing the mandatory insurance against work related accidents. We estimated linear models for a measure of the severity of the workplace accident. We controlled for time-invariant fixed effects at worker and firm levels to disentangle the impact of the type of contract from the spurious one induced by unobservables at worker and firm levels. Workers with a temporary contract, if subject to a workplace accident, were more likely to be confronted with severe injuries than permanent workers. When correcting the statistical analysis for injury under-reporting of temporary workers, we found that most of, but not all, the effect is driven by the under-reporting bias. The effect of temporary contracts on the injury severity survived the inclusion of worker and firm fixed effects and the correction for temporary workers' injury under-reporting. This, however, does not exclude the possibility that, within firms, the nature of the work may vary between different categories of workers. For example, temporary workers might be more likely to be assigned dangerous tasks because they might have less bargaining power. The findings will help in designing public policy effective in increasing temporary workers' safety at work and limiting their injury under-reporting. Copyright © 2017. Published by Elsevier Ltd.

  13. Temporary Cementitious Sealers in Enhanced Geothermal Systems

    Energy Technology Data Exchange (ETDEWEB)

    Sugama T.; Pyatina, T.; Butcher, T.; Brothers, L.; Bour, D.

    2011-12-31

    Unlike conventional hydrothennal geothermal technology that utilizes hot water as the energy conversion resources tapped from natural hydrothermal reservoir located at {approx}10 km below the ground surface, Enhanced Geothermal System (EGS) must create a hydrothermal reservoir in a hot rock stratum at temperatures {ge}200 C, present in {approx}5 km deep underground by employing hydraulic fracturing. This is the process of initiating and propagating a fracture as well as opening pre-existing fractures in a rock layer. In this operation, a considerable attention is paid to the pre-existing fractures and pressure-generated ones made in the underground foundation during drilling and logging. These fractures in terms of lost circulation zones often cause the wastage of a substantial amount of the circulated water-based drilling fluid or mud. Thus, such lost circulation zones must be plugged by sealing materials, so that the drilling operation can resume and continue. Next, one important consideration is the fact that the sealers must be disintegrated by highly pressured water to reopen the plugged fractures and to promote the propagation of reopened fractures. In response to this need, the objective of this phase I project in FYs 2009-2011 was to develop temporary cementitious fracture sealing materials possessing self-degradable properties generating when {ge} 200 C-heated scalers came in contact with water. At BNL, we formulated two types of non-Portland cementitious systems using inexpensive industrial by-products with pozzolanic properties, such as granulated blast-furnace slag from the steel industries, and fly ashes from coal-combustion power plants. These byproducts were activated by sodium silicate to initiate their pozzolanic reactions, and to create a cemetitious structure. One developed system was sodium silicate alkali-activated slag/Class C fly ash (AASC); the other was sodium silicate alkali-activated slag/Class F fly ash (AASF) as the binder of temper

  14. Pedicle screw anchorage of carbon fiber-reinforced PEEK screws under cyclic loading.

    Science.gov (United States)

    Lindtner, Richard A; Schmid, Rene; Nydegger, Thomas; Konschake, Marko; Schmoelz, Werner

    2018-03-01

    Pedicle screw loosening is a common and significant complication after posterior spinal instrumentation, particularly in osteoporosis. Radiolucent carbon fiber-reinforced polyetheretherketone (CF/PEEK) pedicle screws have been developed recently to overcome drawbacks of conventional metallic screws, such as metal-induced imaging artifacts and interference with postoperative radiotherapy. Beyond radiolucency, CF/PEEK may also be advantageous over standard titanium in terms of pedicle screw loosening due to its unique material properties. However, screw anchorage and loosening of CF/PEEK pedicle screws have not been evaluated yet. The aim of this biomechanical study therefore was to evaluate whether the use of this alternative nonmetallic pedicle screw material affects screw loosening. The hypotheses tested were that (1) nonmetallic CF/PEEK pedicle screws resist an equal or higher number of load cycles until loosening than standard titanium screws and that (2) PMMA cement augmentation further increases the number of load cycles until loosening of CF/PEEK screws. In the first part of the study, left and right pedicles of ten cadaveric lumbar vertebrae (BMD 70.8 mg/cm 3  ± 14.5) were randomly instrumented with either CF/PEEK or standard titanium pedicle screws. In the second part, left and right pedicles of ten vertebrae (BMD 56.3 mg/cm 3  ± 15.8) were randomly instrumented with either PMMA-augmented or nonaugmented CF/PEEK pedicle screws. Each pedicle screw was subjected to cyclic cranio-caudal loading (initial load ranging from - 50 N to + 50 N) with stepwise increasing compressive loads (5 N every 100 cycles) until loosening or a maximum of 10,000 cycles. Angular screw motion ("screw toggling") within the vertebra was measured with a 3D motion analysis system every 100 cycles and by stress fluoroscopy every 500 cycles. The nonmetallic CF/PEEK pedicle screws resisted a similar number of load cycles until loosening as the contralateral standard

  15. Temporary brittle bone disease: fractures in medical care.

    Science.gov (United States)

    Paterson, Colin R

    2009-12-01

    Temporary brittle bone disease is the name given to a syndrome first reported in 1990, in which fractures occur in infants in the first year of life. The fractures include rib fractures and metaphyseal fractures which are mostly asymptomatic. The radiological features of this disorder mimic those often ascribed to typical non-accidental injury. The subject has been controversial, some authors suggesting that the disorder does not exist. This study reports five infants with typical features of temporary brittle bone disease in whom all or most of the fractures took place while in hospital. A non-accidental cause can be eliminated with some confidence, and these cases provide evidence in support of the existence of temporary brittle bone disease.

  16. Transforming knowledge across domains in the temporary development spaces

    DEFF Research Database (Denmark)

    Brønnum, Louise

    This paper addresses transformation of knowledge across different knowledge domains and competencies in the Front End of Innovation (FEI) [Koen 2002].We examine the temporary spaces [Clausen, Yoshinaka 2007] that emerge when different knowledge domains are brought into play (implicit or explicit......) in staging innovative concept development. FEI appears as temporary spaces for innovative processes; and studies have pointed out the limited uptake of user knowledge (Elgaard Jensen 2012). This paper will discuss the possibilities and barriers for uptake of user knowledge in FEI in relation...... to the constitutions of these temporary spaces. There seems to be a limited understanding of: how knowledge is transferred and transformed into design objects facilitating a process where knowledge enables innovative thinking across knowledge boundaries. The paper is based on empirical data primarily from case studies...

  17. Role of postreplication repair in transformation of human fibroblasts to anchorage independence

    International Nuclear Information System (INIS)

    Boyer, J.C.; Kaufmann, W.K.; Cordeiro-Stone, M.

    1991-01-01

    Cellular capacity for postreplication repair (PRR) and sensitivity to transformation to anchorage independence (AI) were quantified in normal foreskin and xeroderma pigmentosum (XP) variant fibroblasts after treatment with UV or benzo(a)pyrene-diol-epoxide I (BPDE-I). PRR is defined here as a collection of pathways that facilitate the replication of DNA damaged by genotoxic agents. It is recognized biochemically as the process by which nascent DNA grows longer than the average distance between two lesions in the DNA template. PRR refers more directly to the elimination of gaps in the daughter-strand DNA by mechanisms which remain to be determined for human cells, but which may include translesion replication and recombination. PRR was measured in diploid human fibroblasts by analysis of the dose kinetics for inhibition of DNA strand growth in carcinogen-treated cells. Logarithmically growing foreskin fibroblasts (NHF1) displayed D0 values of 4.3 J/m 2 and 0.14 microM for the inhibition of DNA synthesis in active replicons by UV and BPDE-I, respectively. XP variant cells (CRL1162) exhibited corresponding D0 values of 1.5 J/m 2 and 0.16 microM. The increased sensitivity to inhibition of DNA replication by UV in these XP variant fibroblasts (2.9-fold greater than normal) was mirrored by an enhanced frequency of transformation to AI. XP variant fibroblasts (CRL1162) were 3.2 times more sensitive to transformation to AI by UV than were the normal foreskin fibroblasts. As predicted by the PRR studies, both cell types exhibited similar frequencies of AI colonies induced by BPDE-I. Apparent thresholds were observed for induction of AI by UV (normal fibroblasts, 2.7 J/m 2 ; XP variant fibroblasts, 0.3 J/m 2 ) and BPDE-I (both, 0.05 microM)

  18. Enhanced caveolin-1 expression increases migration, anchorage-independent growth and invasion of endometrial adenocarcinoma cells

    International Nuclear Information System (INIS)

    Diaz-Valdivia, Natalia; Bravo, Denisse; Huerta, Hernán; Henriquez, Soledad; Gabler, Fernando; Vega, Margarita; Romero, Carmen; Calderon, Claudia; Owen, Gareth I.; Leyton, Lisette; Quest, Andrew F. G.

    2015-01-01

    Caveolin-1 (CAV1) has been implicated both in tumor suppression and progression, whereby the specific role appears to be context dependent. Endometrial cancer is one of the most common malignancies of the female genital tract; however, little is known about the role of CAV1 in this disease. Here, we first determined by immunohistochemistry CAV1 protein levels in normal proliferative human endometrium and endometrial tumor samples. Then using two endometrial cancer cell lines (ECC: Ishikawa and Hec-1A) we evaluated mRNA and protein levels of CAV1 by real time qPCR and Western blot analysis, respectively. The role of CAV1 expression in ECC malignancy was further studied by either inducing its expression in endometrial cancer cells with the tumor promotor 12-O-tetradecanoyl-phorbol-13-acetate (4β-TPA) or decreasing expression using short-hairpin RNA constructs, and then evaluating the effects of these changes on ECC proliferation, transmigration, matrigel invasion, and colony formation in soft agar. Immunohistochemical analysis of endometrial epithelia revealed that substantially higher levels of CAV1 were present in endometrial tumors than the normal proliferative epithelium. Also, in Ishikawa and Hec-1A endometrial cancer cells CAV1 expression was readily detectable. Upon treatment with 4β-TPA CAV1 levels increased and coincided with augmented cell transmigration, matrigel invasion, as well as colony formation in soft agar. Reduction of CAV1 expression using short-hairpin RNA constructs ablated these effects in both cell types whether treated or not with 4β-TPA. Alternatively, CAV1 expression appeared not to modulate significantly proliferation of these cells. Our study shows that elevated CAV1, observed in patients with endometrial cancer, is linked to enhanced malignancy of endometrial cancer cells, as evidenced by increased migration, invasion and anchorage-independent growth. The online version of this article (doi:10.1186/s12885-015-1477-5) contains

  19. The influence of social anchorage on the gender difference in the use of mental health services.

    Science.gov (United States)

    Drapeau, Aline; Boyer, Richard; Lesage, Alain

    2009-07-01

    Overall, women are more likely than men to seek professional care when they face light or moderate mental health problems. This difference is usually attributed to culture-related factors, but neither women nor men form a homogeneous cultural group. The help-seeking behavior may reflect not only the cultural values and expectations associated with a specific gender but also those associated with specific social roles endorsed by women and men. In addition, the influence of these culture-related factors on the help-seeking behavior is constrained by barriers to care, which apply similarly to women and men. In consequence, the gender difference in the use of mental health services should vary across social roles and types of service. This hypothesis was tested on data from the cycle 1.2 of the Canadian Community Health Survey. Logistic regression analyses show that, although women are more likely than men to use mental health services, this gender difference is larger for general services than for psychiatric and psychological services whose access in Canada is constrained, respectively, by systemic and financial barriers to care. They also suggest that holding the role of worker tends to foster the use of psychological services in women, especially in married women, and to a lesser degree in men, whereas it tends to hinder the use of general and psychiatric services in men but to exert no or less influence in women. Thus, professional anchorage seems to be an important source of the societal norms that influence the decision of women and men to seek or not to seek medical care for mental health problems.

  20. Recorded earthquake responses from the integrated seismic monitoring network of the Atwood Building, Anchorage, Alaska

    Science.gov (United States)

    Celebi, M.

    2006-01-01

    An integrated seismic monitoring system with a total of 53 channels of accelerometers is now operating in and at the nearby free-field site of the 20-story steel-framed Atwood Building in highly seismic Anchorage, Alaska. The building has a single-story basement and a reinforced concrete foundation without piles. The monitoring system comprises a 32-channel structural array and a 21-channel site array. Accelerometers are deployed on 10 levels of the building to assess translational, torsional, and rocking motions, interstory drift (displacement) between selected pairs of adjacent floors, and average drift between floors. The site array, located approximately a city block from the building, comprises seven triaxial accelerometers, one at the surface and six in boreholes ranging in depths from 15 to 200 feet (???5-60 meters). The arrays have already recorded low-amplitude shaking responses of the building and the site caused by numerous earthquakes at distances ranging from tens to a couple of hundred kilometers. Data from an earthquake that occurred 186 km away traces the propagation of waves from the deepest borehole to the roof of the building in approximately 0.5 seconds. Fundamental structural frequencies [0.58 Hz (NS) and 0.47 Hz (EW)], low damping percentages (2-4%), mode coupling, and beating effects are identified. The fundamental site frequency at approximately 1.5 Hz is close to the second modal frequencies (1.83 Hz NS and 1.43 EW) of the building, which may cause resonance of the building. Additional earthquakes prove repeatability of these characteristics; however, stronger shaking may alter these conclusions. ?? 2006, Earthquake Engineering Research Institute.

  1. Protein disulfide isomerases in the endoplasmic reticulum promote anchorage-independent growth of breast cancer cells.

    Science.gov (United States)

    Wise, Randi; Duhachek-Muggy, Sara; Qi, Yue; Zolkiewski, Michal; Zolkiewska, Anna

    2016-06-01

    Metastatic breast cancer cells are exposed to stress of detachment from the extracellular matrix (ECM). Cultured breast cancer cells that survive this stress and are capable of anchorage-independent proliferation form mammospheres. The purpose of this study was to explore a link between mammosphere growth, ECM gene expression, and the protein quality control system in the endoplasmic reticulum (ER). We compared the mRNA and protein levels of ER folding factors in SUM159PT and MCF10DCIS.com breast cancer cells grown as mammospheres versus adherent conditions. Publicly available gene expression data for mammospheres formed by primary breast cancer cells and for circulating tumor cells (CTCs) were analyzed to assess the status of ECM/ER folding factor genes in clinically relevant samples. Knock-down of selected protein disulfide isomerase (PDI) family members was performed to examine their roles in SUM159PT mammosphere growth. We found that cells grown as mammospheres had elevated expression of ECM genes and ER folding quality control genes. CTC gene expression data for an index patient indicated that upregulation of ECM and ER folding factor genes occurred at the time of acquired therapy resistance and disease progression. Knock-down of PDI, ERp44, or ERp57, three members of the PDI family with elevated protein levels in mammospheres, in SUM159PT cells partially inhibited the mammosphere growth. Thus, breast cancer cell survival and growth under detachment conditions require enhanced assistance of the ER protein folding machinery. Targeting ER folding factors, in particular members of the PDI family, may improve the therapeutic outcomes in metastatic breast cancer.

  2. Deploying temporary networks for upscaling of sparse network stations

    Science.gov (United States)

    Coopersmith, Evan J.; Cosh, Michael H.; Bell, Jesse E.; Kelly, Victoria; Hall, Mark; Palecki, Michael A.; Temimi, Marouane

    2016-10-01

    Soil observations networks at the national scale play an integral role in hydrologic modeling, drought assessment, agricultural decision support, and our ability to understand climate change. Understanding soil moisture variability is necessary to apply these measurements to model calibration, business and consumer applications, or even human health issues. The installation of soil moisture sensors as sparse, national networks is necessitated by limited financial resources. However, this results in the incomplete sampling of the local heterogeneity of soil type, vegetation cover, topography, and the fine spatial distribution of precipitation events. To this end, temporary networks can be installed in the areas surrounding a permanent installation within a sparse network. The temporary networks deployed in this study provide a more representative average at the 3 km and 9 km scales, localized about the permanent gauge. The value of such temporary networks is demonstrated at test sites in Millbrook, New York and Crossville, Tennessee. The capacity of a single U.S. Climate Reference Network (USCRN) sensor set to approximate the average of a temporary network at the 3 km and 9 km scales using a simple linear scaling function is tested. The capacity of a temporary network to provide reliable estimates with diminishing numbers of sensors, the temporal stability of those networks, and ultimately, the relationship of the variability of those networks to soil moisture conditions at the permanent sensor are investigated. In this manner, this work demonstrates the single-season installation of a temporary network as a mechanism to characterize the soil moisture variability at a permanent gauge within a sparse network.

  3. Temporary sharing prompts unrestrained disclosures that leave lasting negative impressions.

    Science.gov (United States)

    Hofstetter, Reto; Rüppell, Roland; John, Leslie K

    2017-11-07

    With the advent of social media, the impressions people make on others are based increasingly on their digital disclosures. However, digital disclosures can come back to haunt, making it challenging for people to manage the impressions they make. In field and online experiments in which participants take, share, and evaluate self-photographs ("selfies"), we show that, paradoxically, these challenges can be exacerbated by temporary-sharing media-technologies that prevent content from being stored permanently. Relative to permanent sharing, temporary sharing affects both whether and what people reveal. Specifically, temporary sharing increases compliance with the request to take a selfie (study 1) and induces greater disclosure risks (i.e., people exhibit greater disinhibition in their selfies, studies 1 and 2). This increased disclosure is driven by reduced privacy concerns (study 2). However, observers' impressions of sharers are insensitive to permanence (i.e., whether the selfie was shared temporarily versus permanently) and are instead driven by the disinhibition exhibited in the selfie (studies 4-7). As a result, induced by the promise of temporary sharing, sharers of uninhibited selfies come across as having worse judgment than those who share relatively discreet selfies (studies 1, 2, and 4-7)-an attributional pattern that is unanticipated by sharers (study 3), that persists days after the selfie has disappeared (study 5), is robust to personal experience with temporary sharing (studies 6A and 6B), and holds even among friends (studies 7A and 7B). Temporary sharing may bring back forgetting, but not without introducing new (self-presentational) challenges. Copyright © 2017 the Author(s). Published by PNAS.

  4. Temporary hyperthyroidism (hypertriiodothyroninemia) to be evoked by stress

    International Nuclear Information System (INIS)

    Ehni, A.; Kampmann, H.

    1982-01-01

    From patients of intensive care unit suffering from acute myocardial infarction, decompensated hypertension with left heart insufficiency, severe coronary heart disease, pulmonary infarction, cerebral ischemia 102 were selected with suspicion of hyperthyroidism because of clinical signs. 12 patients fulfilled the criteria of temporary hyperthyroidism, 6 patients revealed persistent hyperthyroidism. Excluding other causes for evoked hyperthyroidism as common etiological factor psychogenic stress is discussed. It is concluded, that increased thyroid hormone concentration in patients of intensive care units should be controlled within a short time in order to delineate temporary hyperthyroidism against permanent hyperthyroidism. (orig.) [de

  5. Eosinophilic cellulitis (Wells’ syndrome) caused by a temporary henna tattoo

    Science.gov (United States)

    Celegen, Mehmet; Karkıner, Canan Sule Unsal; Günay, Ilker; Diniz, Güllden; Can, Demet

    2014-01-01

    Eosinophilic cellulitis (Wells’ syndrome) is an uncommon condition of unknown etiology. Wells’ syndrome is usually seen in adulthood but very rare in childhood. Although pathogenesis of the disease is not very clear, it is a hypersensitivity reaction developing against a variety of exogenous and endogenous antigenic stimuli. Paraphenylenediamine is a strong allergen frequently used as a temporary henna tattoo, which makes the color darker. Here, a 9-year-old male patient with Wells’ syndrome is presented, which developed following a temporary henna tattoo and shown by the patch test sensitivity to paraphenylenediamine. PMID:25395929

  6. Multiple Institutional Logics in Inter-Institutional Temporary Organizations

    DEFF Research Database (Denmark)

    Pemsel, Sofia; Söderlund, Jonas

    for the planning and construction of a new super hospital in the capital of Sweden. Our empirical data demonstrates the important role institutional logics contribute with in understanding logics behind actions as well as emerging conflicts in practice throughout the project process. The paper identifies four......The idea of multiple institutional logics currently draws more and more attention as many organizational actors are forced to operate in ever more complex, temporary and vivid collaborations. We draw on findings from a unique case study of a temporary organization that carried the responsibility...

  7. Temporary emergency pacing-an orphan in district hospitals

    DEFF Research Database (Denmark)

    Gjesdal, Knut; Johansen, Jens Brock; Gadler, Fredrik

    2012-01-01

    This editorial discusses a report on the 1 year experience with temporary pacing, especially in the emergency setting, in several Norwegian district hospitals. The vast majority of the patients received transvenous temporary pacing, and the majority of leads were placed by noncardiologists....... The procedure times were long and complications were frequent. The organization of emergency pacing is discussed, and we suggest that unless qualified physicians can establish transvenous pacing, the patients who need that should be transferred with transcutaneous pacing as back-up during transport...

  8. Incidental Detection of Temporary Focal FDG Retention in the Spleen

    Energy Technology Data Exchange (ETDEWEB)

    Park, Youn Joon; Lee, Jai Hyuen; Jee, Keum Nahn; Namgung, Hwan [Dankook Univ. College of Medicine, Seoul (Korea, Republic of)

    2011-06-15

    F 18 fluorodeoxyglucose (FDG) positron emission tomography (PET)/computed tomography (CT) is a valuable tool in discriminating malignancy from benign lesion. But because various false positive results reduce the diagnostic specificity, nuclear medicine physicians should be familiar with possible false positive cases. Although many cases of high FDG uptake mimicking malignancy have been reported, temporary intense focal FDG uptake of normal spleen has not been reported previously. We report herein a phenomenon of temporary intense focal FDG uptake of normal spleen without evidence of metastasis in a 46 year old woman with a history of anal cancer.

  9. Temporary hyperthyroidism (hypertriiodothyroninemia) to be evoked by stress

    Energy Technology Data Exchange (ETDEWEB)

    Ehni, A.; Kampmann, H.

    1982-10-01

    From patients of intensive care unit suffering from acute myocardial infarction, decompensated hypertension with left heart insufficiency, severe coronary heart disease, pulmonary infarction, cerebral ischemia 102 were selected with suspicion of hyperthyroidism because of clinical signs. 12 patients fulfilled the criteria of temporary hyperthyroidism, 6 patients revealed persistent hyperthyroidism. Excluding other causes for evoked hyperthyroidism as common etiological factor psychogenic stress is discussed. It is concluded, that increased thyroid hormone concentration in patients of intensive care units should be controlled within a short time in order to delineate temporary hyperthyroidism against permanent hyperthyroidism.

  10. Exits from Temporary Jobs in Europe: A Competing Risks Analysis

    DEFF Research Database (Denmark)

    D'Addio, Anna Christina; Rosholm, Michael

    2005-01-01

    We study transitions out of temporary jobs using the waves 1994-1999 of the European Community Household Panel applying a discrete time duration model. Specifically, we use a multinomial logitmodel distinguishing between exits into permanent employment and non-employment. Two different specificat......We study transitions out of temporary jobs using the waves 1994-1999 of the European Community Household Panel applying a discrete time duration model. Specifically, we use a multinomial logitmodel distinguishing between exits into permanent employment and non-employment. Two different...

  11. Role of management devices in enacting strategy

    DEFF Research Database (Denmark)

    Harritz, Daniel

    2016-01-01

    the SSC’s creation. Originality/value - This study is the first to use a performative method to highlight the temporary and local nature of enacting strategic decisions to construct an SSC in the public sector. Keywords: Management control, SSC, strategic change, actor-network theory, organizational......Purpose - This study illustrates the role of management devices in enacting strategy and strategic decisions, resulting in the development of a Shared Service Centre (SSC) in a Danish municipality. It shows how devices interact in defending, rejecting and reframing strategy, leading to the closure...... the active role of non-human entities, such as management devices, in enacting and reformulating strategy. Findings - Different devices have become key actants in shaping and formulating the new strategy in the municipality and the strategic decision to construct a SSC. However, different devices mobilise...

  12. Comparison of rate of En masse retraction and anchorage loss in conventional labial appliance with labial and lingual force: A clinical study

    Directory of Open Access Journals (Sweden)

    Dilshad Quraishi

    2018-01-01

    Full Text Available Aims: The rate of en masse retraction and anchorage loss were compared between labial appliance with lingual force and conventional labial appliance. Subjects and Methods: The sample consists of 14 patients and they were divided into two groups. In Group 1 – labial appliance with lingual force, elastomeric chain was placed from the palatal surface of the canines to the palatal surface of the molars. In Group 2 – labial appliance with labial force, elastomeric chain was placed from the crimpable hook distal to lateral incisor to the molar tube hooks. The rate of en masse retraction and anchorage loss was calculated for both the groups during retraction in dental casts (R0, initial; R1, 4 weeks; R2, 8 weeks; and R3, 12 weeks. Statistical Analysis Used: Student's paired t-test. Results: The rate of retraction was faster and anchorage loss was lower with labial appliance with lingual force, i.e., Group 1. The difference of anchorage loss in Group 1 and Group 2 shows t = 4.824 and P value= 0.000, which is statistically highly significant. The difference of rate of retraction in Group 1 and Group 2 shows t = 3.573 and P value = 0.004, which is statistically signifcant. Conclusions: The rate of retraction was faster and anchorage loss was lower with labial appliance with lingual force, thus indicating that this new technique of space closure utilizes biomechanical advantage of lingual force in conventional labial appliance.

  13. Photovoltaic device

    Energy Technology Data Exchange (ETDEWEB)

    Reese, Jason A; Keenihan, James R; Gaston, Ryan S; Kauffmann, Keith L; Langmaid, Joseph A; Lopez, Leonardo; Maak, Kevin D; Mills, Michael E; Ramesh, Narayan; Teli, Samar R

    2017-03-21

    The present invention is premised upon an improved photovoltaic device ("PV device"), more particularly to an improved photovoltaic device with a multilayered photovoltaic cell assembly and a body portion joined at an interface region and including an intermediate layer, at least one interconnecting structural member, relieving feature, unique component geometry, or any combination thereof.

  14. Photovoltaic device

    Science.gov (United States)

    Reese, Jason A.; Keenihan, James R.; Gaston, Ryan S.; Kauffmann, Keith L.; Langmaid, Joseph A.; Lopez, Leonardo C.; Maak, Kevin D.; Mills, Michael E.; Ramesh, Narayan; Teli, Samar R.

    2015-06-02

    The present invention is premised upon an improved photovoltaic device ("PV device"), more particularly to an improved photovoltaic device with a multilayered photovoltaic cell assembly and a body portion joined at an interface region and including an intermediate layer, at least one interconnecting structural member, relieving feature, unique component geometry, or any combination thereof.

  15. Photovoltaic device

    Science.gov (United States)

    Reese, Jason A.; Keenihan, James R.; Gaston, Ryan S.; Kauffmann, Keith L.; Langmaid, Joseph A.; Lopez, Leonardo C.; Maak, Kevin D.; Mills, Michael E.; Ramesh, Narayan; Teli, Samar R.

    2015-09-01

    The present invention is premised upon an improved photovoltaic device ("PV device"), more particularly to an improved photovoltaic device (10) with a multilayered photovoltaic cell assembly (100) and a body portion (200) joined at an interface region (410) and including an intermediate layer (500), at least one interconnecting structural member (1500), relieving feature (2500), unique component geometry, or any combination thereof.

  16. Spheroid Culture of Head and Neck Cancer Cells Reveals an Important Role of EGFR Signalling in Anchorage Independent Survival.

    Science.gov (United States)

    Braunholz, Diana; Saki, Mohammad; Niehr, Franziska; Öztürk, Merve; Borràs Puértolas, Berta; Konschak, Robert; Budach, Volker; Tinhofer, Ingeborg

    2016-01-01

    In solid tumours millions of cells are shed into the blood circulation each day. Only a subset of these circulating tumour cells (CTCs) survive, many of them presumable because of their potential to form multi-cellular clusters also named spheroids. Tumour cells within these spheroids are protected from anoikis, which allows them to metastasize to distant organs or re-seed at the primary site. We used spheroid cultures of head and neck squamous cell carcinoma (HNSCC) cell lines as a model for such CTC clusters for determining the role of the epidermal growth factor receptor (EGFR) in cluster formation ability and cell survival after detachment from the extra-cellular matrix. The HNSCC cell lines FaDu, SCC-9 and UT-SCC-9 (UT-SCC-9P) as well as its cetuximab (CTX)-resistant sub-clone (UT-SCC-9R) were forced to grow in an anchorage-independent manner by coating culture dishes with the anti-adhesive polymer poly-2-hydroxyethylmethacrylate (poly-HEMA). The extent of apoptosis, clonogenic survival and EGFR signalling under such culture conditions was evaluated. The potential of spheroid formation in suspension culture was found to be positively correlated with the proliferation rate of HNSCC cell lines as well as their basal EGFR expression levels. CTX and gefitinib blocked, whereas the addition of EGFR ligands promoted anchorage-independent cell survival and spheroid formation. Increased spheroid formation and growth were associated with persistent activation of EGFR and its downstream signalling component (MAPK/ERK). Importantly, HNSCC cells derived from spheroid cultures retained their clonogenic potential in the absence of cell-matrix contact. Addition of CTX under these conditions strongly inhibited colony formation in CTX-sensitive cell lines but not their resistant subclones. Altogether, EGFR activation was identified as crucial factor for anchorage-independent survival of HNSCC cells. Targeting EGFR in CTC cluster formation might represent an attractive anti

  17. Mini-screw implant or transpalatal arch-mediated anchorage reinforcement during canine retraction: a randomized clinical trial.

    Science.gov (United States)

    Sharma, Mohit; Sharma, Vineet; Khanna, Bharat

    2012-06-01

    To compare mesial movement of upper first molars during maxillary canine retraction using a pre-adjusted edgewise appliance provided by anchorage reinforcement and a transpalatal arch or mini-screw implant. Randomized clinical trial. Department of Orthodontics and Dentofacial Orthopedics, Armed Forces Medical College, Pune, India. From a cohort of subjects requiring the extraction of both upper first premolars and pre-adjusted edgewise appliances to correct their malocclusion, a total of 30 were randomly allocated to receive two different forms of anchorage reinforcement: group A--receiving mini-screw implant and group B--receiving a transpalatal arch Group A subjects received titanium mini-screw implants placed at the start of treatment between the maxillary second premolar and maxillary first molar. Maxillary second premolars were secured to the mini-screw implants using of 0.010-inch stainless steel ligature wire. Group B subjects received a custom-made transpalatal arch which was soldered to maxillary first molar bands. Active canine retraction was initiated in both groups on placement of a 0.019×0.025-inch stainless steel archwire using nickel titanium closed coil springs. Mesial movement of the upper first molars as measured on pre- (T1) and post-treatment (T2) lateral skull radiographs. The results showed that in group A the mean mesial movement of the first molars between T1 and T2 was 0.0 mm (SD 0.02; P = 0.90), whereas in Group B there was a mean forward movement of the first maolars of 2.48 mm (SD 0.71; Pimplants placed prior to levelling and aligning were able to provide absolute anchorage during maxillary canine retraction, in contrast to a transpalatal arch.

  18. The Liminality of Temporary Agency Work: Exploring the Dimensions of Danish Temporary Agency Workers’ Liminal Experience

    Directory of Open Access Journals (Sweden)

    Ingo Winkler

    2015-03-01

    Full Text Available The concept of liminality refers to the experience to be betwixt-and-between social structures and the associated positions, statuses, and roles. We advance the original use of the concept by introducing the various meanings that the experience of being in a liminal state can take. Drawing on political anthropology we identify the dimensions of ‘types of subjects,’ ‘time,’ ‘space,’ and ‘scale’ in order to analytically unlock the liminal experience. Exemplifying our concept we present the findings from an own study of temporary agency workers in Denmark. Exploring the workers’ interpretations allows us to illustrate to what extent their employment situation constitutes a multi-dimensional liminal experience between established social structures and employment categories. The article emphasizes the complexity of the liminal experience. Theoretically and empirically, we show the many meanings along which liminality can unfold in organizational and work-related contexts. We argue that future studies should explore the various dimensions in other contexts of passages from one relatively stable state to another. In doing so, similarities and differences between various liminal experiences and the role the various dimensions play could be identified.

  19. 76 FR 35909 - Temporary Concession Contract for Blue Ridge Parkway

    Science.gov (United States)

    2011-06-20

    ... accommodations, food and beverage, retail sales, boat rentals, and other services at Crabtree Falls, Price Lake... DEPARTMENT OF THE INTERIOR National Park Service [NPS-WASO-CONC-0511-7182; 2410-OYC] Temporary Concession Contract for Blue Ridge Parkway AGENCY: National Park Service, Interior. ACTION: Notice of...

  20. Fate and monitoring of hazardous substances in temporary rivers

    NARCIS (Netherlands)

    Ademollo, N.; Capri, S.; Froebrich, J.; Patrolecco, L.; Polesello, S.; Puddu, A.; Rusconi, M.; Valsecchi, S.

    2011-01-01

    Under climate-change conditions, temporary rivers will be the dominant surface-water bodies of the Mediterranean region. In order to manage this kind of water body appropriately, it is necessary to understand the chemical and ecological processes that involve hazardous substances in these

  1. Characterizing temporary hydrological regimes at a European scale

    NARCIS (Netherlands)

    Kirkby, M.J.; Gallart, F.; Kjeldsen, T.R.; Irvine, B.J.; Froebrich, J.; Porto, Lo A.

    2011-01-01

    Monthly duration curves have been constructed from climate data across Europe to help address the relative frequency of ecologically critical low flow stages in temporary rivers, when flow persists only in disconnected pools in the river bed. The hydrological model is 5 based on a partitioning of

  2. Temporary worker in the nuclear power industry: an equity analysis

    International Nuclear Information System (INIS)

    Melville, M.H.

    1981-01-01

    There are clear indications based both on the statistical data and on empirical evidence that the employment of large numbers of temporary workers has become a permanent and growing characteristic of the industry. It appears that the size of that work force has been seriously underestimated and that it receives a disproportionate share of the occupational radiation. In order to stay within the limits governing individual exposure in the workplace, the risk has been spread among a larger segment of the population. These facts raise important and ongoing issues of societal and employer responsibility. By the reckonings of this study, the total number of workers employed on a temporary basis by the nuclear power industry is eighteen times greater than those much more narrowly defined by the Nuclear Regulatory Commission (NRC) as transient workers: individuals hired and terminating employment with two or more employers in one quarter. It is estimated that the whole temporary work force numbered about 23,520 in 1976, over a third (35%) of the industry total, and absorbed 47.5% of the total occupational radiation dose. The problems, then, are not inconsiderable: they affect thousands of individuals, a significant segment of the nuclear power industry's work force, members of society who are subjected to a disproportionate burden of radiation risk. Among the conclusions is that it may be necessary to establish special standards, limitations, and records for temporary workers to ensure adequate health protection, follow-up, and care

  3. Understanding the development of temporary agency work in Europe

    NARCIS (Netherlands)

    B.A.S. Koene (Bas); J. Paauwe (Jaap); J.P.M. Groenewegen (John)

    2004-01-01

    textabstractThis article develops an explanatory framework for understanding the growth and development of temporary agency work (TAW) and the related industry. The analysis shows that explanations based on economic logic are helpful in understanding the choice of TAW in general. These explanations,

  4. 26 CFR 1.897-5T - Corporate distributions (temporary).

    Science.gov (United States)

    2010-04-01

    ... also subject to the tax avoidance rules of § 1.897-6T(c). (b) Distributions by domestic corporations—(1... TAX (CONTINUED) INCOME TAXES Miscellaneous Provisions § 1.897-5T Corporate distributions (temporary...) Any U.S. tax paid by or on behalf of the distributee with respect to the distribution. (2...

  5. Managing temporary workers: work identity, diversity and operational HR choices

    NARCIS (Netherlands)

    Koene, Bas; van Riemsdijk, Maarten

    2005-01-01

    Strategic HRM theory argues that organisations should distinguish different types of employees according to their value and availability. We argue that this has resulted in an underestimation of the importance of specific HRM practices in relation to temporary employees. Building on theoretical work

  6. 41 CFR 101-1.103 - FPMR temporary regulations.

    Science.gov (United States)

    2010-07-01

    ... 41 Public Contracts and Property Management 2 2010-07-01 2010-07-01 true FPMR temporary regulations. 101-1.103 Section 101-1.103 Public Contracts and Property Management Federal Property Management Regulations System FEDERAL PROPERTY MANAGEMENT REGULATIONS GENERAL 1-INTRODUCTION 1.1-Regulation System § 101...

  7. 41 CFR 115-1.103 - Temporary-type FPMR.

    Science.gov (United States)

    2010-07-01

    ... 41 Public Contracts and Property Management 3 2010-07-01 2010-07-01 false Temporary-type FPMR. 115-1.103 Section 115-1.103 Public Contracts and Property Management Federal Property Management Regulations System (Continued) ENVIRONMENTAL PROTECTION AGENCY 1-INTRODUCTION 1.1-Regulation System § 115-1...

  8. 20 CFR 655.34 - Validity of temporary labor certifications.

    Science.gov (United States)

    2010-04-01

    ... Attestations for Temporary Employment in Occupations Other Than Agriculture or Registered Nursing in the United... minor changes in the period of employment, only when a written request is submitted to the CO and... to make the labor certification determination required under § 655.32. (4) The CO may change the date...

  9. Temporary and long-term consequences of bereavement on happiness

    NARCIS (Netherlands)

    Moor, J.A.; de Graaf, P.M.

    In this article, we examine the temporary and long-term consequences of the death of a parent or child on happiness. According to set-point theory external conditions are expected to only have a short-term or limited influence on happiness. This directly contradicts the basic assumption of affective

  10. 30 CFR 816.131 - Cessation of operations: Temporary.

    Science.gov (United States)

    2010-07-01

    ..., revegetation, environmental monitoring, and water treatment activities that will continue during the temporary... Section 816.131 Mineral Resources OFFICE OF SURFACE MINING RECLAMATION AND ENFORCEMENT, DEPARTMENT OF THE INTERIOR PERMANENT PROGRAM PERFORMANCE STANDARDS PERMANENT PROGRAM PERFORMANCE STANDARDS-SURFACE MINING...

  11. Language, Employment, and Settlement: Temporary Meat Workers in Australia

    Science.gov (United States)

    Piller, Ingrid; Lising, Loy

    2014-01-01

    Australia is one of the world's largest beef exporters. However, meat processing jobs are widely considered undesirable and are increasingly filled with employer-sponsored migrant workers on temporary long-stay visas. Against this background, our paper explores the role of language in the employment and migration trajectories of a group of meat…

  12. Temporary over voltages in the high voltage networks

    International Nuclear Information System (INIS)

    Vukelja, Petar; Naumov, Radomir; Mrvic, Jovan; Minovski, Risto

    2001-01-01

    The paper treats the temporary over voltages that may arise in the high voltage networks as a result of: ground faults, loss of load, loss of one or two phases and switching operation. Based on the analysis, the measures for their limitation are proposed. (Original)

  13. 5 CFR 351.608 - Permissive temporary exceptions.

    Science.gov (United States)

    2010-01-01

    .... This does not preclude the employee from receiving or accepting a job offer in the same competitive... date beyond the effective date of the reduction in force when the temporary retention of a lower... retention will end; and (2) List opposite the employee's name on the retention register the reasons for the...

  14. Temporary Agency Work as a Means of Achieving Flexicurity?

    Directory of Open Access Journals (Sweden)

    Kristina Håkansson

    2012-11-01

    Full Text Available After decades of debate about flexibility, flexicurity has become a new buzzword in working life. Flexicurity refers to both the employer’s demand for flexibility and the employee’s demand for security. Thus, the idea is to solve the flexibility–security trade-off. There is also a discussion that mentions temporary agency work as one way of creating a flexicurity system. The flexibility potential is not called into question—numerical flexibility is a quite common motive for using temporary agency workers. However, the security dimension has to be scrutinized. The aim of this article is to analyze the temporary work agency industry’s potential for providing the security dimensions of the flexicurity model in a Swedish context. The study is based on a survey of whitecollar temporary agency workers in Sweden (n = 533. Overall, the vast majority do not perceive security. Our most important result is that both the work agency and the user firm have a dual impact on the agency workers’ perception of security.

  15. Umbilical site for temporary colostomy in anorectal malformations: is ...

    African Journals Online (AJOL)

    Umbilical site for temporary colostomy in anorectal malformations: is it cosmetically preferable? Taha Alkhatrawi, Radi Elsherbini and Djamal Ouslimane. Purpose In an attempt to minimize the scars and improve the cosmetic outcome in children, the umbilical site has been chosen for colostomy formation in patients with.

  16. Early closure of temporary ileostomy--the EASY trial

    DEFF Research Database (Denmark)

    Danielsen, Anne Kjaergaard; Correa-Marinez, Adiela; Angenete, Eva

    2011-01-01

    Reversal of a temporary ileostomy is generally associated with a low morbidity and mortality. However, ostomy reversal may cause complications requiring reoperation with subsequent major complications, in ranges from 0% to 7-9% and minor complications varying from 4-5% to 30%. Based on studies exploring...

  17. 36 CFR 223.37 - Revegetation of temporary roads.

    Science.gov (United States)

    2010-07-01

    ... roads. 223.37 Section 223.37 Parks, Forests, and Public Property FOREST SERVICE, DEPARTMENT OF... Provisions § 223.37 Revegetation of temporary roads. Timber sale contracts, permits and other documents... roads constructed or used thereunder so as to permit the reestablishment by artificial or natural means...

  18. 75 FR 63184 - Temporary Duty (TDY) Travel Allowances

    Science.gov (United States)

    2010-10-14

    ... GENERAL SERVICES ADMINISTRATION [Docket 2010-0009, Sequence 4] Temporary Duty (TDY) Travel Allowances AGENCY: Office of Governmentwide Policy, General Services Administration (GSA). ACTION: Notice of... agency travel programs, save money on travel costs, better protect the environment, and conserve natural...

  19. Survey of absence. The use of photographic data for the survey of temporary art exhibitions.

    Directory of Open Access Journals (Sweden)

    Matteo Ballarin

    2013-10-01

    Full Text Available Modern Art Exhibitions succeeded in conveying long-lasting ideas and meanings despite their ephemeral nature. Art history and Museum studies recently started to focus on the Exhibition as a medium, requiring precise graphic reconstructions of exhibit designs for critical and theoretical purposes. Exhibitions were rarely designed through graphic devices such as the project; they were usually a result of improvisation processes. In this sense, photographs are the only documents for graphic reconstructions of temporary art spaces. Nevertheless, the photographic datum has been over-edited in its span of life for more than one reason: it requires a critical approach to be used as a source. The use of digital tools for photography can lead to satisfactory results when applied to humanities.

  20. Three-dimensional printing spiders: back-and-forth glue application yields silk anchorages with high pull-off resistance under varying loading situations.

    Science.gov (United States)

    Wolff, Jonas O; Herberstein, Marie E

    2017-02-01

    The anchorage of structures is a crucial element of construction, both for humans and animals. Spiders use adhesive plaques to attach silk threads to substrates. Both biological and artificial adhesive structures usually have an optimal loading angle, and are prone to varying loading situations. Silk anchorages, however, must cope with loading in highly variable directions. Here we show that the detachment forces of thread anchorages of orb-web spiders are highly robust against pulling in different directions. This is gained by a two-step back-and-forth spinning pattern during the rapid production of the adhesive plaque, which shifts the thread insertion point towards the plaque centre and forms a flexible tree root-like network of branching fibres around the loading point. Using a morphometric approach and a tape-and-thread model we show that neither area, nor width of the plaque, but the shift of the loading point towards the plaque centre has the highest effect on pull-off resistance. This is explained by a circular propagation of the delamination crack with a low peeling angle. We further show that silken attachment discs are highly directional and adjusted to provide maximal performance in the upstream dragline. These results show that the way the glue is applied, crucially enhances the toughness of the anchorage without the need of additional material intake. This work is a starting point to study the evolution of tough and universal thread anchorages among spiders, and to develop bioinspired 'instant' anchorages of thread- and cable-like structures to a broad bandwidth of substrates. © 2017 The Author(s).

  1. Temporary work and depressive symptoms: a propensity score analysis.

    Science.gov (United States)

    Quesnel-Vallée, Amélie; DeHaney, Suzanne; Ciampi, Antonio

    2010-06-01

    Recent decades have seen a tremendous increase in the complexity of work arrangements, through job sharing, flexible hours, career breaks, compressed work weeks, shift work, reduced job security, and part-time, contract and temporary work. In this study, we focus on one specific group of workers that arguably most embodies non-standard employment, namely temporary workers, and estimate the effect of this type of employment on depressive symptom severity. Accounting for the possibility of mental health selection into temporary work through propensity score analysis, we isolate the direct effects of temporary work on depressive symptoms with varying lags of time since exposure. We use prospective data from the U.S. National Longitudinal Survey of Youth 1979 (NLSY79), which has followed, longitudinally, from 1979 to the present, a nationally representative cohort of American men and women between 14 and 22 years of age in 1979. Three propensity score models were estimated, to capture the effect of different time lags (immediately following exposure, and 2 and 4 years post exposure) between the period of exposure to the outcome. The only significant effects were found among those who had been exposed to temporary work in the two years preceding the outcome measurement. These workers report 1.803 additional depressive symptoms from having experienced this work status (than if they had not been exposed). Moreover, this difference is both statistically and substantively significant, as it represents a 50% increase from the average level of depressive symptoms in this population. Copyright 2010 Elsevier Ltd. All rights reserved.

  2. Communities of belonging in the temporariness of the Danish Asylum System: Shalini’s anchoring points

    DEFF Research Database (Denmark)

    Verdasco, Andrea

    2018-01-01

    Refugees often find themselves in a protracted situation of temporariness, as applications for asylum are processed, deportations negotiated and possible extensions of temporary protection status considered within the context of increasingly restrictive governmental policies across Europe. Through...

  3. A diatom functional-based approach to assess changing environmental conditions in temporary depressional wetlands

    CSIR Research Space (South Africa)

    Riato, L

    2017-07-01

    Full Text Available is limited although important for the development of temporary wetland biological assessments. We assessed how diatom life-form and ecological guilds responded to a seasonal hydrological and hydrochemical gradient in three least human-disturbed, temporary...

  4. Physical performance deterioration of temporary housing residents after the Great East Japan Earthquake

    Directory of Open Access Journals (Sweden)

    Takeaki Ishii

    2015-01-01

    We revealed that standing stability was impaired among elderly temporary housing residents 1.5 years after the disaster. Disaster responders should take into account the health risks associated with living in temporary housing.

  5. Working conditions, work life and quality of life of the temporary ...

    African Journals Online (AJOL)

    Working conditions, work life and quality of life of the temporary support staff ... and expectations of the temporary support staff with regard to their working ... conditions mainly as unpleasant, but that they adapted because of the team spirit.

  6. 5 CFR 890.1105 - Initial election of temporary continuation of coverage; application time limitations and...

    Science.gov (United States)

    2010-01-01

    ... (ii) The date of the divorce or annulment. (e) If an individual who is eligible for temporary... determines that an eligible individual was unable, for cause beyond his or her control, to elect temporary...

  7. 78 FR 46339 - Medicare, Medicaid, and Children's Health Insurance Programs: Announcement of Temporary Moratoria...

    Science.gov (United States)

    2013-07-31

    ...] Medicare, Medicaid, and Children's Health Insurance Programs: Announcement of Temporary Moratoria on... combat fraud, waste, and abuse in Medicare, Medicaid, and the Children's Health Insurance Program (CHIP... Health Insurance Programs; Additional Screening Requirements, Application Fees, Temporary Enrollment...

  8. Diatom-based models for inferring water chemistry and hydrology in temporary depressional wetlands

    CSIR Research Space (South Africa)

    Riato, L

    2017-08-01

    Full Text Available Information on the response of temporary depressional wetland diatoms to human-induced disturbances is a limited and important component for the development of temporary wetland biological assessments in human-modified landscapes. Establishing a...

  9. Sealing device

    Science.gov (United States)

    Garcia-Crespo, Andres Jose

    2013-12-10

    A sealing device for sealing a gap between a dovetail of a bucket assembly and a rotor wheel is disclosed. The sealing device includes a cover plate configured to cover the gap and a retention member protruding from the cover plate and configured to engage the dovetail. The sealing device provides a seal against the gap when the bucket assemply is subjected to a centrifugal force.

  10. Microfluidic Device

    Science.gov (United States)

    Tai, Yu-Chong (Inventor); Zheng, Siyang (Inventor); Lin, Jeffrey Chun-Hui (Inventor); Kasdan, Harvey L. (Inventor)

    2017-01-01

    Described herein are particular embodiments relating to a microfluidic device that may be utilized for cell sensing, counting, and/or sorting. Particular aspects relate to a microfabricated device that is capable of differentiating single cell types from dense cell populations. One particular embodiment relates a device and methods of using the same for sensing, counting, and/or sorting leukocytes from whole, undiluted blood samples.

  11. Gauging device

    International Nuclear Information System (INIS)

    Qurnell, F.D.; Patterson, C.B.

    1979-01-01

    A gauge supporting device for measuring say a square tube comprises a pair of rods or guides in tension between a pair of end members, the end members being spaced apart by a compression member or members. The tensioned guides provide planes of reference for measuring devices moved therealong on a carriage. The device is especially useful for making on site dimensional measurements of components, such as irradiated and therefore radioactive components, that cannot readily be transported to an inspection laboratory. (UK)

  12. Asymmetrical distalization of maxillary molars with zygomatic anchorage, improved superelastic nickel-titanium alloy wires, and open-coil springs.

    Science.gov (United States)

    Ishida, Takayoshi; Yoon, Hyung Sik; Ono, Takashi

    2013-10-01

    In nongrowing patients with skeletal Class II malocclusion, premolar extraction or maxillary distalization can be used as camouflage treatment. Zygomatic anchorage enables distalization in uncooperative or noncompliant patients. We describe 1 such procedure in a 24-year-old woman. We used novel improved superelastic nickel-titanium archwires combined with nickel-titanium open-coil springs to provide a constant and continuous low force to the dentition. We were able to successfully eliminate the protrusive profile and correct the Class II molar relationship using this system of zygomatic anchorage. The posterior occlusal relationships were improved to achieve Class I canine and molar relationships on both sides, and ideal overbite and overjet relationships were established. Facial esthetics was improved with decreased protrusion of the upper and lower lips. The method used here is a promising alternative to traditional distalization techniques and might offer an effective and simple means of distalizing maxillary molars in uncooperative patients. Copyright © 2013 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  13. [Comparison between J-hook and micro-implant anchorage in the treatment of patients with bimaxillary protrusion].

    Science.gov (United States)

    Chen, Wen-Jing; Li, Qing-Yi; Gong, Ai-Xiu; Hu, Fang; Gu, Yong-Jia

    2008-02-01

    To compare the difference between J-hook and micro-implant anchorage in the treatment of patient with bimaxillary protrusion. Thirty patients with bimaxillary protrusion were divided into two groups (J-hook and micro-implant groups) and treated with MBT appliance. Four first premolars were extracted in all patients. Cephalometric analyses were carried out before and after treatment. In J-hook group and micro-implant group,computerized cephalometric analysis revealed that before treatment U6C-PP was (12.4 +/- 0.2) mm and (12.5 +/- 0.1) mm, respectively,and after treatment U6C-PP was (12.6 +/- 0.1) mm and (12.8 +/- 0.1) mm,respectively. The difference between J-hook group and microimplant group was significant (P micro-implant group was not significant. Both J-hook and micro-implant could provide adequate anchorage in the treatment of patients with bimaxillary protrusion.

  14. Morphologic and hemodynamic analysis of dental pulp in dogs after molar intrusion with the skeletal anchorage system.

    Science.gov (United States)

    Konno, Yuichi; Daimaruya, Takayoshi; Iikubo, Masahiro; Kanzaki, Reiko; Takahashi, Ichiro; Sugawara, Junji; Sasano, Takashi

    2007-08-01

    We have successfully treated skeletal open bite by intruding posterior teeth with the skeletal anchorage system. Our aim in this study was to morphologically and hemodynamically evaluate the changes in pulp tissues when molars are radically intruded. The mandibular fourth premolars of 9 adult beagle dogs were divided into 3 groups: a sham operated group (n = 6, 3 dogs), 4-month intrusion group (n = 6, 3 dogs), and a further 4-month retention group (n = 6, 3 dogs). We evaluated the morphological changes of the pulp and dentin-the amount of vacuolar degeneration in the odontoblast layer, the predentin width and nervous continuity in the pulp tissue, and the pulpal blood-flow response evoked by electrical stimulation in the dental pulp. Extreme molar intrusion with the skeletal anchorage system caused slight degenerative changes in the pulp tissue, followed by recovery after the orthodontic force was released. Circulatory system and nervous functions were basically maintained during the intrusion, although a certain level of downregulation was observed. These morphologic and functional regressive changes in the pulp tissue after molar intrusion improved during the retention period. Histologic changes and changes in pulpal blood flow and function are reversible, even during radical intrusion of molars.

  15. Bst1 is required for Candida albicans infecting host via facilitating cell wall anchorage of Glycosylphosphatidyl inositol anchored proteins

    Science.gov (United States)

    Liu, Wei; Zou, Zui; Huang, Xin; Shen, Hui; He, Li Juan; Chen, Si Min; Li, Li Ping; Yan, Lan; Zhang, Shi Qun; Zhang, Jun Dong; Xu, Zheng; Xu, Guo Tong; An, Mao Mao; Jiang, Yuan Ying

    2016-01-01

    Glycosylphosphatidyl inositol anchored proteins (GPI-APs) on fungal cell wall are essential for invasive infections. While the function of inositol deacylation of GPI-APs in mammalian cells has been previously characterized the impact of inositol deacylation in fungi and implications to host infection remains largely unexplored. Herein we describe our identification of BST1, an inositol deacylase of GPI-Aps in Candida albicans, was critical for GPI-APs cell wall attachment and host infection. BST1-deficient C. albicans (bst1Δ/Δ) was associated with severely impaired cell wall anchorage of GPI-APs and subsequen unmasked β-(1,3)-glucan. Consistent with the aberrant cell wall structures, bst1Δ/Δ strain did not display an invasive ability and could be recognized more efficiently by host immune systems. Moreover, BST1 null mutants or those expressing Bst1 variants did not display inositol deacylation activity and exhibited severely attenuated virulence and reduced organic colonization in a murine systemic candidiasis model. Thus, Bst1 can facilitate cell wall anchorage of GPI-APs in C. albicans by inositol deacylation, and is critical for host invasion and immune escape. PMID:27708385

  16. 33 CFR 74.01-15 - Charges for placement of temporary aids.

    Science.gov (United States)

    2010-07-01

    ... temporary aids. 74.01-15 Section 74.01-15 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY AIDS TO NAVIGATION CHARGES FOR COAST GUARD AIDS TO NAVIGATION WORK Charges to the Public § 74.01-15 Charges for placement of temporary aids. Charges for placement of temporary aids will be...

  17. 76 FR 34080 - Agency Information Collection Activities; Proposed Collection; Comment Request; Temporary...

    Science.gov (United States)

    2011-06-10

    ...] Agency Information Collection Activities; Proposed Collection; Comment Request; Temporary Marketing... appropriate, and other forms of information technology. Temporary Marketing Permit Applications--21 CFR 130.17... submitted recent requests for temporary marketing permits. Based on this information, we estimate that there...

  18. Temporary Contracts: Effect on Job Satisfaction and Personal Lives of Recent Phd Graduates

    Science.gov (United States)

    Waaijer, Cathelijn J. F.; Belder, Rosalie; Sonneveld, Hans; van Bochove, Cornelis A.; van der Weijden, Inge C. M.

    2017-01-01

    In this study, we assess the effects of temporary employment on job satisfaction and the personal lives of recent PhD graduates. Temporary employment is becoming increasingly prevalent in many sectors, but has been relatively common in academia, especially for early career scientists. Labor market theory shows temporary employment to have a…

  19. 29 CFR 4.176 - Payment of fringe benefits to temporary and part-time employees.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 1 2010-07-01 2010-07-01 true Payment of fringe benefits to temporary and part-time... to temporary and part-time employees. (a) As set forth in § 4.165(a)(2), the Act makes no distinction, with respect to its compensation provisions, between temporary, part-time, and full-time employees...

  20. The Temporary Help Industry: A Response to the Dual Internal Labor Market.

    Science.gov (United States)

    Mangum, Garth; And Others

    1985-01-01

    This study of the rapidly growing temporary help industry draws on Commerce Department data and the results of the authors' national mail survey of employers. The authors also conducted interviews in the San Francisco area with employers of temporary help and with representatives of temporary help agencies and labor unions. (Author/CT)

  1. 75 FR 11627 - Order Granting Temporary Exemptions From Certain Government Securities Act Provisions and...

    Science.gov (United States)

    2010-03-11

    ... DEPARTMENT OF THE TREASURY Order Granting Temporary Exemptions From Certain Government Securities... Department of the Treasury (Treasury) is granting temporary exemptions from certain Government Securities Act...).pdf. \\8\\ 75 FR 4626, January 28, 2010 Order Granting a Temporary Exemption from Certain Government...

  2. Fusion devices

    International Nuclear Information System (INIS)

    Fowler, T.K.

    1977-01-01

    Three types of thermonuclear fusion devices currently under development are reviewed for an electric utilities management audience. Overall design features of laser fusion, tokamak, and magnetic mirror type reactors are described and illustrated. Thrusts and trends in current research on these devices that promise to improve performance are briefly reviewed. Twenty photographs and drawings are included

  3. BRAKE DEVICE

    Science.gov (United States)

    O'Donnell, T.J.

    1959-03-10

    A brake device is described for utilization in connection with a control rod. The device comprises a pair of parallelogram link mechanisms, a control rod moveable rectilinearly therebetween in opposite directions, and shoes resiliently supported by the mechanism for frictional engagement with the control rod.

  4. Simple Device for Treating Prolapsing Loop Colostomy

    Directory of Open Access Journals (Sweden)

    Ming-Yu Hsieh

    2006-03-01

    Full Text Available Stoma prolapse is a common complication of intestinal stoma. Although various surgical methods yield satisfactory results, nonsurgical treatment may be better for a temporary stoma. We report a case of a patient with a distal limb prolapse of a right transverse colostomy who received nonsurgical treatment with satisfactory results. For the treatment of a temporary transverse loop colostomy with distal limb prolapse, we designed a simple device consisting of a pediatric plastic medicine cup, which was rolled into a towel to shape the bottom of the cup into a compressor. The towel was put on the stoma outside of the colostomy bag with the compressor above the prolapsing limb of the colostomy. An abdominal binder was applied to fix the towel.

  5. AGENCY CONTRIBUTION IN ACHIEVING TEMPORARY AGENCY WORKERS’ ORGANIZATIONAL COMMITMENT: A STUDY IN ABC (PVT LTD

    Directory of Open Access Journals (Sweden)

    T.G.T.N Perera

    2017-12-01

    Full Text Available Temporary agency workers are coming under non-standard employments, who have temporary attachment to the working organization. With dynamic business environment and flexible work arrangements, temporary agency employments are also emerged in Sri Lanka. Temporary agency workers are dual committed employees. However, with this dual commitment, organizations face issues in achieving temporary agency workers’ commitment due to low attention of agencies to temporary agency workers. Even though the Client organization provides due attention to temporary agency workers, they fail to receive due commitment due to the lack of attention from agency to temporary agency workers. This study was conducted to identify the agency related factors affecting temporary agency workers’ commitment. This was carried out as a cross sectional field study with a sample of 93 workers from temporary agency works in the ABC (pvt ltd. 93 temporary agency workers were selected as sample. Data were collected via a standard questionnaire that met accepted standards of validity and reliability. Descriptive statistics, Simple ranking, Factor analysis, ANOVA and Independent Sample T-Test technique were performed to analyze data. No of Temporary workers to supervisor (temp to consult ratio is the most influencing factor of temporary agency workers’ commitment in agency context. Job satisfaction, agency support, side bets, interactional justice, lack of alternative employments, procedural justice, distributive justice, reciprocity norm acceptance, socialization, breach of psychological contract, lack of skill transferability are the other factors, which are ordered from most influencing factor to less affecting factor to workers’ organizational commitment . Findings revealed that eleven out of thirteen factors are job related factors, other two are organization related and person related factors. Most client companies provide their attention, while agencies fail to provide

  6. PLASMA DEVICE

    Science.gov (United States)

    Gow, J.D.; Wilcox, J.M.

    1961-12-26

    A device is designed for producing and confining highenergy plasma from which neutrons are generated in copious quantities. A rotating sheath of electrons is established in a radial electric field and axial magnetic field produced within the device. The electron sheath serves as a strong ionizing medium to gas introdueed thereto and also functions as an extremely effective heating mechanism to the resulting plasma. In addition, improved confinement of the plasma is obtained by ring magnetic mirror fields produced at the ends of the device. Such ring mirror fields are defined by the magnetic field lines at the ends of the device diverging radially outward from the axis of the device and thereafter converging at spatial annular surfaces disposed concentrically thereabout. (AFC)

  7. Radioactive gas waste processing device

    International Nuclear Information System (INIS)

    Soma, Koichi.

    1996-01-01

    The present invention concerns a radioactive gas waste processing device which extracts exhaust gases from a turbine condensator in a BWR type reactor and releases them after decaying radioactivity thereof during temporary storage. The turbine condensator is connected with an extracting ejector, a preheater, a recombiner for converting hydrogen gas into steams, an off gas condensator for removing water content, a flow rate control valve, a dehumidifier, a hold up device for removing radiation contaminated materials, a vacuum pump for sucking radiation decayed-off gases, a circulation water tank for final purification and an exhaustion cylinder by way of connection pipelines in this order. An exhaust gas circulation pipeline is disposed to circulate exhaust gases from an exhaust gas exit pipeline of the recycling water tank to an exhaust gas exit pipeline of the exhaust gas condensator, and a pressure control valve is disposed to the exhaust gas circulation pipeline. This enable to perform a system test for the dehumidification device under a test condition approximate to the load of the dehumidification device under actual operation state, and stabilize both of system flow rate and pressure. (T.M.)

  8. Temporary Life Changes and the Timing of Divorce.

    Science.gov (United States)

    Fallesen, Peter; Breen, Richard

    2016-10-01

    Marriage is a risky undertaking that people enter with incomplete information about their partner and their future life circumstances. A large literature has shown how new information gained from unforeseen but long-lasting or permanent changes in life circumstances may trigger a divorce. We extend this literature by considering how information gained from a temporary change in life circumstances-in our case, a couple having a child with infantile colic-may affect divorce behavior. Although persistent life changes are known to induce divorce, we argue that a temporary stressful situation allows couples more quickly to discern the quality of their relationship, in some cases leading them to divorce sooner than they otherwise would have. We formalize this argument in a model of Bayesian updating and test it using data from Denmark. We find that the incidence of infantile colic shortens the time to divorce or disruption among couples who would have split up anyway.

  9. Plant experience with temporary reverse osmosis makeup water systems

    International Nuclear Information System (INIS)

    Polidoroff, C.

    1986-01-01

    Pacific Gas and Electric (PG and E) Company's Diablo Canyon Power Plant (DCPP), which is located on California's central coast, has access to three sources of raw water: creek water, well water, and seawater. Creek and well water are DCPP's primary sources of raw water; however, because their supply is limited, these sources are supplemented with seawater. The purpose of this paper is to discuss the temporary, rental, reverse osmosis systems used by PG and E to process DCPP's raw water into water suitable for plant makeup. This paper addresses the following issues: the selection of reverse osmosis over alternative water processing technologies; the decision to use vendor-operated temporary, rental, reverse osmosis equipment versus permanent PG and E-owned and -operated equipment; the performance of DCPP's rental reverse osmosis systems; and, the lessons learned from DCPP's reverse osmosis system rental experience that might be useful to other plants considering renting similar equipment

  10. Need for relevant timescales when crediting temporary carbon storage

    DEFF Research Database (Denmark)

    Jørgensen, Susanne Vedel; Hauschild, Michael Zwicky

    2013-01-01

    carbon storage in carbon footprinting. Methods: Implications of using a 100-year accounting period is evaluated via a literature review study of the global carbon cycle, as well as by analysing the crediting approaches that are exemplified by the PAS 2050 scheme for crediting temporary carbon storage......-term climatic benefits is considered to require storage of carbon for at least thousand years. However, it has been proposed that there may exist tipping points for the atmospheric CO2 concentration beyond which irreversible climate changes occur. To reduce the risk of passing such tipping points, fast...... mitigation of the rise in atmospheric greenhouse gas concentration is required and in this perspective, shorter storage times may still provide climatic benefits. Conclusions: Both short- and long-term perspectives should be considered when crediting temporary carbon storage, addressing both acute effects...

  11. Mapping the temporary and perennial character of whole river networks

    Science.gov (United States)

    González-Ferreras, A. M.; Barquín, J.

    2017-08-01

    Knowledge of the spatial distribution of temporary and perennial river channels in a whole catchment is important for effective integrated basin management and river biodiversity conservation. However, this information is usually not available or is incomplete. In this study, we present a statistically based methodology to classify river segments from a whole river network (Deva-Cares catchment, Northern Spain) as temporary or perennial. This method is based on an a priori classification of a subset of river segments as temporary or perennial, using field surveys and aerial images, and then running Random Forest models to predict classification membership for the rest of the river network. The independent variables and the river network were derived following a computer-based geospatial simulation of riverine landscapes. The model results show high values of overall accuracy, sensitivity, and specificity for the evaluation of the fitted model to the training and testing data set (≥0.9). The most important independent variables were catchment area, area occupied by broadleaf forest, minimum monthly precipitation in August, and average catchment elevation. The final map shows 7525 temporary river segments (1012.5 km) and 3731 perennial river segments (662.5 km). A subsequent validation of the mapping results using River Habitat Survey data and expert knowledge supported the validity of the proposed maps. We conclude that the proposed methodology is a valid method for mapping the limits of flow permanence that could substantially increase our understanding of the spatial links between terrestrial and aquatic interfaces, improving the research, management, and conservation of river biodiversity and functioning.

  12. How Does Temporary Agency Work Impact German Agency Workers?

    OpenAIRE

    Spermann, Alexander

    2013-01-01

    The enormous speed of change in the working world is associated with greater job insecurity. As a dynamic external flexibilization instrument, temporary agency work is characterized by high labor turnover rates. As a result, agency workers might perceive more job insecurity than permanent staff. This paper surveys German empirical studies on outcome variables such as job satisfaction, commitment, health, employability, social participation and effects on personal life for agency workers. It i...

  13. Evaluation of color stability of different temporary restorative materials

    Directory of Open Access Journals (Sweden)

    José Vitor Quinelli Mazaro

    Full Text Available AbstractIntroductionTemporary restorative materials are widely used, however, little is know about their color stability.Objectiveto evaluate the color stability of the following temporary restorative materials: acrylic and bis-acrylic resins after immersion in pigmenting solutions for different periods of storage.Material and methodFour materials were tested (Dêncor/Clássico, Protemp 4/3M ESPE; Structur 2 SC/Voco; Luxatemp AM Plus/DMG and 30 test specimens (15 mm in diameter and 2 mm thick per material were fabricated. They were divided according to the storage medium (artificial saliva, saliva + cola type soda, and saliva + coffee and storage time intervals (2, 5, 7 and 15 days. Color measurements were made before and after immersions, with use of a spectrophotometer, by means of the CIE L*a*b* system. The data were analyzed by the analysis of variance and the Tukey Test, at a level of significance of 5%.ResultAcrylic resin presented greater color stability in comparison with bis-acrylic resins (p<0.001. When bis-acrylic resins were compared no significant difference was observed between the resins Structur and Luxatemp (p=0.767. As regards solutions tested, coffee showed the highest color change values (p<0.001, and the longer the storage time interval, the greater was the color change in all the temporary restorative materials analyzed (p<0.001.ConclusionAcrylic resin presented greater color stability in comparison with bis-acrylic resins (p<0.001. Coffee caused the greatest color change, and immersion time was determinant in color stability of the temporary materials analyzed.

  14. Carbon Reduction Measures-Based LCA of Prefabricated Temporary Housing with Renewable Energy Systems

    Directory of Open Access Journals (Sweden)

    Ling Dong

    2018-03-01

    Full Text Available Temporary housing plays an important role in providing secure, hygienic, private, and comfortable shelter in the aftermath of disaster (such as flood, fire, earthquake, etc.. Additionally, temporary housing can also be used as a sustainable form of on-site residences for construction workers. While most of the building components used in temporary housing can be manufactured in a plant, prefabrication technology improves the production efficiency of temporary housing; furthermore, integrated renewable energy systems, for example, solar photovoltaic (PV system, offer benefits for temporary housing operations. In order to assess the environmental impacts of prefabricated temporary housing equipped with renewable energy systems, this study first divides the life cycle of temporary housing into six stages, and then establishes a life cycle assessment (LCA model for each stage. Furthermore, with the aim of reducing the environmental impacts, life cycle carbon reduction measures are proposed for each stage of temporary housing. The proposed methodology is demonstrated using a case study in China. Based on the proposed carbon reduction measures, the LCA of a prefabricated temporary housing case study building equipped with renewable energy systems indicates a carbon emissions intensity of 35.7 kg/m2·per year, as well as a reduction in material embodied emissions of 18%, assembly emissions of 17.5%, and operational emissions of 91.5%. This research proposes a carbon reduction-driven LCA of temporary housing and contributes to promoting sustainable development of prefabricated temporary housing equipped with renewable energy systems.

  15. Role for cER and Mmr1p in anchorage of mitochondria at sites of polarized surface growth in budding yeast.

    Science.gov (United States)

    Swayne, Theresa C; Zhou, Chun; Boldogh, Istvan R; Charalel, Joseph K; McFaline-Figueroa, José Ricardo; Thoms, Sven; Yang, Christine; Leung, Galen; McInnes, Joseph; Erdmann, Ralf; Pon, Liza A

    2011-12-06

    Mitochondria accumulate at neuronal and immunological synapses and yeast bud tips and associate with the ER during phospholipid biosynthesis, calcium homeostasis, and mitochondrial fission. Here we show that mitochondria are associated with cortical ER (cER) sheets underlying the plasma membrane in the bud tip and confirm that a deletion in YPT11, which inhibits cER accumulation in the bud tip, also inhibits bud tip anchorage of mitochondria. Time-lapse imaging reveals that mitochondria are anchored at specific sites in the bud tip. Mmr1p, a member of the DSL1 family of tethering proteins, localizes to punctate structures on opposing surfaces of mitochondria and cER sheets underlying the bud tip and is recovered with isolated mitochondria and ER. Deletion of MMR1 impairs bud tip anchorage of mitochondria without affecting mitochondrial velocity or cER distribution. Deletion of the phosphatase PTC1 results in increased Mmr1p phosphorylation, mislocalization of Mmr1p, defects in association of Mmr1p with mitochondria and ER, and defects in bud tip anchorage of mitochondria. These findings indicate that Mmr1p contributes to mitochondrial inheritance as a mediator of anchorage of mitochondria to cER sheets in the yeast bud tip and that Ptc1p regulates Mmr1p phosphorylation, localization, and function. Copyright © 2011 Elsevier Ltd. All rights reserved.

  16. Remains of the ancient ports and anchorage points at Miyani and Visawada, on the west coast of India: A study based on underwater investigations

    Digital Repository Service at National Institute of Oceanography (India)

    Gaur, A.S.; Sundaresh; Tripati, S.

    as an excellent natural harbour. The important antiquities include varieties of stone anchors, which are very similar to those reported from Dwarka and Bet Dwarka. The identification of ancient anchorage points between water depth of 5 and 15 m is another...

  17. Barium promotes anchorage-independent growth and invasion of human HaCaT keratinocytes via activation of c-SRC kinase.

    Science.gov (United States)

    Thang, Nguyen Dinh; Yajima, Ichiro; Kumasaka, Mayuko Y; Ohnuma, Shoko; Yanagishita, Takeshi; Hayashi, Rumiko; Shekhar, Hossain U; Watanabe, Daisuke; Kato, Masashi

    2011-01-01

    Explosive increases in skin cancers have been reported in more than 36 million patients with arsenicosis caused by drinking arsenic-polluted well water. This study and previous studies showed high levels of barium as well as arsenic in the well water. However, there have been no reports showing a correlation between barium and cancer. In this study, we examined whether barium (BaCl(2)) may independently have cancer-related effects on human precancerous keratinocytes (HaCaT). Barium (5-50 µM) biologically promoted anchorage-independent growth and invasion of HaCaT cells in vitro. Barium (5 µM) biochemically enhanced activities of c-SRC, FAK, ERK and MT1-MMP molecules, which regulate anchorage-independent growth and/or invasion. A SRC kinase specific inhibitor, protein phosphatase 2 (PP2), blocked barium-mediated promotion of anchorage-independent growth and invasion with decreased c-SRC kinase activity. Barium (2.5-5 µM) also promoted anchorage-independent growth and invasion of fibroblasts (NIH3T3) and immortalized nontumorigenic melanocytes (melan-a), but not transformed cutaneous squamous cell carcinoma (HSC5 and A431) and malignant melanoma (Mel-ret) cells, with activation of c-SRC kinase. Taken together, our biological and biochemical findings newly suggest that the levels of barium shown in drinking well water independently has the cancer-promoting effects on precancerous keratinocytes, fibroblast and melanocytes in vitro.

  18. Inference about density and temporary emigration in unmarked populations

    Science.gov (United States)

    Chandler, Richard B.; Royle, J. Andrew; King, David I.

    2011-01-01

    Few species are distributed uniformly in space, and populations of mobile organisms are rarely closed with respect to movement, yet many models of density rely upon these assumptions. We present a hierarchical model allowing inference about the density of unmarked populations subject to temporary emigration and imperfect detection. The model can be fit to data collected using a variety of standard survey methods such as repeated point counts in which removal sampling, double-observer sampling, or distance sampling is used during each count. Simulation studies demonstrated that parameter estimators are unbiased when temporary emigration is either "completely random" or is determined by the size and location of home ranges relative to survey points. We also applied the model to repeated removal sampling data collected on Chestnut-sided Warblers (Dendroica pensylvancia) in the White Mountain National Forest, USA. The density estimate from our model, 1.09 birds/ha, was similar to an estimate of 1.11 birds/ha produced by an intensive spot-mapping effort. Our model is also applicable when processes other than temporary emigration affect the probability of being available for detection, such as in studies using cue counts. Functions to implement the model have been added to the R package unmarked.

  19. The Diaspora and Temporary Migrant Workers: Basic Concepts

    Directory of Open Access Journals (Sweden)

    Marija Krstić

    2016-02-01

    Full Text Available The paper looks at the phenomenon of migrant workers who emigrated to Western European countries after World War II. The labor demands created by the economic reconstruction of these countries, most notably Great Britain, West Germany, France, Switzerland, the Benelux countries, Sweden and Austria, coupled with low birth rates and high death rates, made it necessary for them to hire immigrant workers. On the other hand, poor economic conditions, few employment opportunities and a yearning for a higher standard of living drove workers from Italy, Spain, Portugal, Turkey, Yugoslavia, Greece, Ireland, Finland and North Africa to seek work abroad. These temporary migrant workers represent a link between their countries of origin and their host countries, and, as a group of people maintaining links with their native countries, they can also be considered their countries’ diaspora. However, considering the temporary nature of their residence abroad, it is questionable whether they actually are a diaspora. It is for this reason that the paper juxtaposes the phenomena of the diaspora and temporary migrant workers in order to analyze the question of whether, when and how these workers become a diaspora. In particular, it focuses on migrant workers from Yugoslavia, usually referred to as “gastarbajteri” (gastarbeiter, who in the 1960s and 1970s migrated mostly to West Germany, Austria, Australia, France and Switzerland, and on their political treatment by the Yugoslav state.

  20. Temporary vs. Permanent Sub-slab Ports: A Comparative ...

    Science.gov (United States)

    Vapor intrusion (VI) is the migration of subsurface vapors, including radon and volatile organic compounds (VOCs), from the subsurface to indoor air. The VI exposure pathway extends from the contaminant source, which can be impacted soil, non-aqueous phase liquid, or contaminated groundwater, to indoor air-exposure points. Therefore, contaminated matrices may include groundwater, soil, soil gas, and indoor air. VOC contaminants of concern typically include halogenated solvents such as trichloroethene, tetrachloroethene, and chloroform, as well as petroleum hydrocarbons, such as the aromatic VOCs benzene, toluene, and xylenes. Radon is a colorless radioactive gas that is released by radioactive decay of radionuclides in rock and soil that migrate into homes through VI in a similar fashion to VOCs. This project focused on the performance of permanent versus temporary sub-slab sampling ports for the determination of VI of halogenated VOCs and radon into an unoccupied house. VOC and radon concentrations measured simultaneously in soil gas using collocated temporary and permanent ports appeared to be independent of the type of port. The variability between collocated temporary and permanent ports was much less than the spatial variability between different locations within a single residential duplex. The agreement of the majority of VOC and radon concentrations, 0–36% relative percent difference, and 2–19% relative standard deviation respectively, of each sub-sl

  1. Sealing devices

    International Nuclear Information System (INIS)

    Coulson, R.A.

    1980-01-01

    A sealing device for minimising the leakage of toxic or radioactive contaminated environments through a biological shield along an opening through which a flexible component moves that penetrates the shield. The sealing device comprises an outer tubular member which extends over a length not less than the maximum longitudinal movement of the component along the opening. An inner sealing block is located intermediate the length of the component by connectors and is positioned in the bore of the outer tubular member to slide in the bore and effect a seal over the entire longitudinal movement of the component. The cross-section of the device may be circular and the block may be of polytetrafluoroethylene or of nylon impregnated with molybdenum or may be metallic. A number of the sealing devices may be combined into an assembly for a plurality of adjacent longitudinally movable components, each adapted to sustain a tensile load, providing the various drives of a master-slave manipulator. (author)

  2. Ferroelectric devices

    CERN Document Server

    Uchino, Kenji

    2009-01-01

    Updating its bestselling predecessor, Ferroelectric Devices, Second Edition assesses the last decade of developments-and setbacks-in the commercialization of ferroelectricity. Field pioneer and esteemed author Uchino provides insight into why this relatively nascent and interdisciplinary process has failed so far without a systematic accumulation of fundamental knowledge regarding materials and device development.Filling the informational void, this collection of information reviews state-of-the-art research and development trends reflecting nano and optical technologies, environmental regulat

  3. Anchorage failure of young trees in sandy soils is prevented by a rigid central part of the root system with various designs

    Science.gov (United States)

    Danquechin Dorval, Antoine; Meredieu, Céline; Danjon, Frédéric

    2016-01-01

    Background and Aims Storms can cause huge damage to European forests. Even pole-stage trees with 80-cm rooting depth can topple. Therefore, good anchorage is needed for trees to survive and grow up from an early age. We hypothesized that root architecture is a predominant factor determining anchorage failure caused by strong winds. Methods We sampled 48 seeded or planted Pinus pinaster trees of similar aerial size from four stands damaged by a major storm 3 years before. The trees were gathered into three classes: undamaged, leaning and heavily toppled. After uprooting and 3D digitizing of their full root architectures, we computed the mechanical characteristics of the main components of the root system from our morphological measurements. Key Results Variability in root architecture was quite large. A large main taproot, either short and thick or long and thin, and guyed by a large volume of deep roots, was the major component that prevented stem leaning. Greater shallow root flexural stiffness mainly at the end of the zone of rapid taper on the windward side also prevented leaning. Toppling in less than 90-cm-deep soil was avoided in trees with a stocky taproots or with a very big leeward shallow root. Toppled trees also had a lower relative root biomass – stump excluded – than straight trees. Conclusions It was mainly the flexural stiffness of the central part of the root system that secured anchorage, preventing a weak displacement of the stump. The distal part of the longest taproot and attached deep roots may be the only parts of the root system contributing to anchorage through their maximum tensile load. Several designs provided good anchorage, depending partly on available soil depth. Pole-stage trees are in-between the juvenile phase when they fail by toppling and the mature phase when they fail by uprooting. PMID:27456136

  4. DIRECT USAGE OF MINISCREW ANCHORAGE TO INTRUDE OVERERUPTED MAXILLARY POSTERIOR TEETH BEFORE PROSTHODONTIC PREPARATION:A CASE REPORT

    Directory of Open Access Journals (Sweden)

    Yasemin Bahar Acar

    2016-01-01

    Full Text Available Overeruption of maxillary molars due loss of opposing teeth creates occlusal and functional interferences. Before reconstruction can be initiated, intrusion of overerupted molars becomes essential. This report illustrates treatment of overerupted maxillary premolar and molar via direct use of miniscrew anchorage. A 24-year old female had lost first and second left mandibular molars due to pulpal necrotizing agents, resulting with a large alveolar bone defect and overerupted maxillary premolar and molar. She had a history of unsuccessful alveolar distraction of mandibular left premolars to increase the alveolar bone height prior to implant placement. Patient was satisfied with her smile and refused comprehensive orthodontic treatment. Maxillary premolar and molar were intruded segmentally for 4mm in 8 months, using a combination of a mini-implant and partialfixed edgewise appliances. Biological responses of teeth and surrounding bony structures to intrusion appeared normal and acceptable in radiographic and clinical examination.

  5. Anchorage of TiO2-blasted, HA-coated, and machined implants: an experimental study with rabbits

    DEFF Research Database (Denmark)

    Gotfredsen, K; Wennerberg, A; Johansson, C

    1995-01-01

    The purpose of this study was to evaluate the histometrical and biomechanical anchorage of TiO2-blasted implants and TiO2-blasted implants coated with hydroxyapatite. The control implants were machined. Twenty-six rabbits had a total of 156 implants placed in the proximal part of the tibia. Each...... rabbit had a machined, a TiO2-blasted, and a TiO2-blasted, HA-coated implant placed in each tibia. After a healing period of 3 and 12 weeks, respectively, the implants placed in the right tibia were used for removal torque test, and the implants placed in the left tibia were used for histomorphometrical...

  6. [Three dimensional finite element analysis of maxillary anterior teeth retraction with micro-implant anchorage and sliding mechanics].

    Science.gov (United States)

    Zhang, Yi; Zhang, Lei; Fan, Yu-bo; Song, Jin-lin; Deng, Feng

    2009-10-01

    To investigate the biomechanical effects of micro-implant anchorage technique with sliding mechanics on maxillary anterior teeth retraction under different implant insertion heights and different retraction hook heights. The three dimensional finite element model of maxillary anterior teeth retraction force system was constructed with CT scanning and MIMICS software and the relationships between brackets, teeth, wire and micro-implant were simulating the clinical factions. Then the initial tooth displacement was calculated when the insertion heights were 4 mm and 8 mm and the retraction hook heights were 1, 4, 7, 10 mm respectively. With retraction hook height added, the anterior teeth movement changed from lingual crown tipping to labial crown tipping and the intrusion movement was more apparent when the micro-implant was inserted in a higher location. The ideal teeth movement control could be achieved by different insertion heights of micro-implant and different retraction hook heights in straight wire retraction force system.

  7. Characterization of the aspects of osteoprogenitor cell interactions with physical tetracalcium phosphate anchorage on titanium implant surfaces

    Energy Technology Data Exchange (ETDEWEB)

    Ko, Chia-Ling [Advanced Medical Devices and Composites Laboratory, Department of Fiber and Composite Materials, Feng Chia University, Taichung 40724, Taiwan (China); Dental Medical Devices and Materials Research Center, College of Dental Medicine, Kaohsiung Medical University, Kaohsiung 807, Taiwan (China); Chang, Ya-Yuan; Liou, Cian-Hua [Alliance Global Technology Co., Ltd., Kaohsiung Medical Device Special Zone in Southern Taiwan Science Park, Kaohsiung 82151, Taiwan (China); Chen, Wen-Cheng, E-mail: wencchen@fcu.edu.tw [Advanced Medical Devices and Composites Laboratory, Department of Fiber and Composite Materials, Feng Chia University, Taichung 40724, Taiwan (China)

    2015-04-01

    Well-designed implants are used not only to modify the geometry of the implant but also to change the chemical properties of its surfaces. The present study aims to assess the biofunctional effects of tetracalcium phosphate (TTCP) particles as a physical anchor on the implant surface derived through sandblasting. The characteristics of the surface, cell viability, and alkaline phosphatase (ALP) activity toward osteoprogenitor cells (D1) were obtained. D1 cells were cultured on a plain surface that underwent sandblasting and acid etching (SLA) (control SLA group) and on different SLA surfaces with different anchoring TTCP rates (new test groups, M and H). The mean anchoring rates were 57% (M) and 74% (H), and the anchored thickness was estimated to range from 12.6 μm to 18.3 μm. Compared with the control SLA surface on Ti substrate, the new test groups with different TTCP anchoring rates (M and H) failed to improve cell proliferation significantly but had a well-differentiated D1 cell phenotype that enhanced ALP expression in the early stage of cell cultures, specifically, at day 7. Results suggest that the SLA surface with anchored TTCP can accelerate progenitor bone cell mineralization. This study shows the potential clinical application of the constructed geometry in TTCP anchorage on Ti for dental implant surface modification. - Highlights: • TTCP (tetracalcium phosphate) as a physical anchorage on implant is characterized. • Theoretical values of anchored thickness and capping areas were estimated. • TTCP anchored by sandblasting can accelerate progenitor bone cell mineralization. • TTCP anchored on SLA (sandblasting and acid etching) surface is a promising method.

  8. Characterization of the aspects of osteoprogenitor cell interactions with physical tetracalcium phosphate anchorage on titanium implant surfaces

    International Nuclear Information System (INIS)

    Ko, Chia-Ling; Chang, Ya-Yuan; Liou, Cian-Hua; Chen, Wen-Cheng

    2015-01-01

    Well-designed implants are used not only to modify the geometry of the implant but also to change the chemical properties of its surfaces. The present study aims to assess the biofunctional effects of tetracalcium phosphate (TTCP) particles as a physical anchor on the implant surface derived through sandblasting. The characteristics of the surface, cell viability, and alkaline phosphatase (ALP) activity toward osteoprogenitor cells (D1) were obtained. D1 cells were cultured on a plain surface that underwent sandblasting and acid etching (SLA) (control SLA group) and on different SLA surfaces with different anchoring TTCP rates (new test groups, M and H). The mean anchoring rates were 57% (M) and 74% (H), and the anchored thickness was estimated to range from 12.6 μm to 18.3 μm. Compared with the control SLA surface on Ti substrate, the new test groups with different TTCP anchoring rates (M and H) failed to improve cell proliferation significantly but had a well-differentiated D1 cell phenotype that enhanced ALP expression in the early stage of cell cultures, specifically, at day 7. Results suggest that the SLA surface with anchored TTCP can accelerate progenitor bone cell mineralization. This study shows the potential clinical application of the constructed geometry in TTCP anchorage on Ti for dental implant surface modification. - Highlights: • TTCP (tetracalcium phosphate) as a physical anchorage on implant is characterized. • Theoretical values of anchored thickness and capping areas were estimated. • TTCP anchored by sandblasting can accelerate progenitor bone cell mineralization. • TTCP anchored on SLA (sandblasting and acid etching) surface is a promising method

  9. Anchorage onto deciduous teeth: effectiveness of early rapid maxillary expansion in increasing dental arch dimension and improving anterior crowding.

    Science.gov (United States)

    Mutinelli, Sabrina; Manfredi, Mario; Guiducci, Antonio; Denotti, Gloria; Cozzani, Mauro

    2015-01-01

    Anchorage onto permanent dentition is a common procedure in rapid maxillary expansion. However, replacing first permanent molars with the second deciduous molars seems to be an option to reduce some negative side effects during orthodontic treatment. The purpose of this study was to evaluate the dental effect of rapid maxillary expansion with anchorage exclusively onto deciduous teeth performed in the first period of transition. Twenty patients with a lateral cross-bite treated exclusively by a Haas expander in early mixed dentition were retrospectively analyzed before treatment, at appliance removal, and at 21 months out of retention. The sagittal and transverse dimensions, together with the inter-canine arch and irregularity index, were digitally measured on scanned images of dental casts. The patients were compared with three balanced control groups (in total, 60 individuals) matched for gender. Two control groups had the same canine dental class as the treated group at T1, were in the inter-transitional period, and either had or lacked a lateral cross-bite. The last control group was comprised of adolescents in permanent dentition with a dental class I. The statistical analysis was performed by means of repeated-measures ANOVA for paired data and one-way ANOVA, the Kruskal-Wallis test, and the Mann-Whitney test for independent measures (α-level p dentition), the dental arch dimensions of treated patients were similar to those of adolescents with a dental class I and significantly wider than those of patients with a lateral cross-bite. Also, the anterior irregularity index was lower among patients who had undergone expansion treatments than in all untreated study participants. The Haas expander anchored to the deciduous teeth is effective in increasing the dental arch width in patients with a lateral cross-bite. The dimensions of the dental arch were modified earlier toward the values of the permanent dentition.

  10. 26 CFR 1.267(a)-2T - Temporary regulations; questions and answers arising under the Tax Reform Act of 1984 (temporary).

    Science.gov (United States)

    2010-04-01

    ... Act of 1984 (temporary). (a) Introduction—(1) Scope. This section prescribes temporary question and... the person to whom the payment is to be made properly uses the completed contract method of accounting... amount is owed to a related person under whose method of accounting such amount is not includible in...

  11. Immediate endovascular stent-graft repair of an acute traumatic

    African Journals Online (AJOL)

    Enrique

    device intended for abdominal deployment. The stent-graft was manually removed from its short delivery device and ... Largely on the basis of the Parmley report, standard teaching was that these injuries ... 5 mm to allow adequate proximal anchorage. Tactics to ... Temporary hypotension is generally induced during the.

  12. Schedules of Controlled Substances: Temporary Placement of ortho-Fluorofentanyl, Tetrahydrofuranyl Fentanyl, and Methoxyacetyl Fentanyl Into Schedule I. Temporary amendment; temporary scheduling order.

    Science.gov (United States)

    2017-10-26

    The Administrator of the Drug Enforcement Administration is issuing this temporary scheduling order to schedule the synthetic opioids, N-(2-fluorophenyl)-N-(1-phenethylpiperidin-4-yl)propionamide (ortho-fluorofentanyl or 2-fluorofentanyl), N-(1-phenethylpiperidin-4-yl)-N-phenyltetrahydrofuran-2-carboxamide (tetrahydrofuranyl fentanyl), and 2-methoxy-N-(1-phenethylpiperidin-4-yl)-N-phenylacetamide (methoxyacetyl fentanyl), into Schedule I. This action is based on a finding by the Administrator that the placement of ortho-fluorofentanyl, tetrahydrofuranyl fentanyl, and methoxyacetyl fentanyl into Schedule I of the Controlled Substances Act is necessary to avoid an imminent hazard to the public safety. As a result of this order, the regulatory controls and administrative, civil, and criminal sanctions applicable to Schedule I controlled substances will be imposed on persons who handle (manufacture, distribute, reverse distribute, import, export, engage in research, conduct instructional activities or chemical analysis, or possess), or propose to handle, ortho-fluorofentanyl, tetrahydrofuranyl fentanyl, and methoxyacetyl fentanyl.

  13. Guide device

    International Nuclear Information System (INIS)

    Brammer, C.M. Jr.

    1977-01-01

    Disclosed is a fuel handling guide tube centering device for use in nuclear reactors during fuel assembly handling operations. The device comprises an outer ring secured to the flange of a nuclear reactor pressure vessel, a rotatable table rotatably coupled to the outer ring, and a plurality of openings through the table. Truncated locating cones are positioned in each of the openings in the table, and the locating cones center the guide tube during fuel handling operations. The openings in the table are located such that each fuel assembly in the nuclear core may be aligned with one of the openings by a suitable rotation of the table. The locating cones thereby provide alignment between the fuel handling mechanism located in the guide tube and the individual fuel assemblies of the cone. The need for a device to provide alignment is especially critical for floating nuclear power plants, where wave motion may exist during fuel handling operations. 5 claims, 4 figures

  14. Clinical outcomes of temporary shunting for infants with cerebral pseudomeningocele.

    Science.gov (United States)

    Mattei, Tobias A; Sambhara, Deepak; Bond, Brandon J; Lin, Julian

    2014-02-01

    Although in the case of subdural collections temporary shunting has been suggested as a viable alternative for definitive drainage of the accumulated fluid until restoration of the normal CSF dynamics, there is no agreement on the best management strategy for pseudomeningocele. The authors performed a retrospective chart review in order to evaluate the clinical outcomes of infants temporarily shunted for pseudomeningocele without encephalocele at our institution (The University of Illinois at Peoria/Illinois Neurological Institute) in the period from 2004 to 2012. The epidemiological characteristics, clinical management, and final outcomes of such subpopulation were compared with a control group which received temporary shunting for subdural hematomas (SDH) during the same period. Four patients (100% male) ranging in age from 8.9 to 27.1 months (mean = 13.88) with pseudomeningocele and 17 patients (64.7% male) ranging in age from 1.9 to 11.8 months (mean = 4.15) with SDH were identified. Although the initial management included sequential percutaneous subdural tapping in 82% of the patients, all children ultimately failed such strategy, requiring either subdural-peritoneal (81% of the cases) or subgaleal-peritoneal (19% of the cases) shunting. The mean implant duration was 201 days for the pseudomeningocele group and 384 days for the SDH one. Mean post-shunt hospitalization was 2 days for patients with pseudomeningocele and 4 days for patients with SDH. There was no statistical difference in terms of complications, length of hospitalization post-shunting, or clinical outcomes between the patients with pseudomeningocele and those with SDH. Temporary shunting of infants with pseudo-meningocele constitutes a viable therapeutic alternative with favorable clinical outcomes and a low risk of shunt dependency similar to those of children with SDH.

  15. Permanent Temporariness? Changes in Social Contracts in Knowledge Work

    Directory of Open Access Journals (Sweden)

    Bente Rasmussen

    2012-02-01

    Full Text Available Many sociologists have argued that work no longer plays the central role in contemporary life experience because we have entered an age of insecurity in relation to employment, and knowledge workers are often pictured as egoistical portfolio workers who are only interested in their careers and no longer loyal to their employers. Cappelli (1999 on the other hand argues that more insecure employment relations is a result of employers’ strategy to buy workers rather than offering them long-term relations. Using case studies from seven different knowledge work contexts in Norway, this article argues that more temporary employment relations is not the result of career-seeking portfolio workers, but of changes in employment practices of their employers. These are not primarily changes in the formal employment contracts from permanent to temporary employment, but in the social contracts as they are practiced by the employers and experienced by the knowledge workers in the different contexts of knowledge work. The reason for more temporary relations was not because work does not matter for knowledge workers. On the contrary, we found that they accepted insecure conditions because work mattered and because they were eager to take on new tasks, learn the trade in new fields, and show that they were able to do the job. When they left their employer, it was because they were not able to do a good job in their positions or because they were increasingly directly exposed to an insecure market that signaled that they were not profitable (enough for their employer. Although changes in employment practices by the employers toward more short-term relations are not caused by disloyal portfolio workers, these practices may produce the problem of disloyal workers who have to secure their employment in the labor market.

  16. WP 54 - Temporary agency work in the Netherlands

    OpenAIRE

    Kea Tijdens; Maarten Klaveren; Marc Meer; Marieke Essen; Hester Houwing

    2007-01-01

    This paper is the result of a study on temp agency workers and on the role that temp agency work played in company’s staffing strategies and on industry and national regulations regarding temp agencies and temp agency work. It was conducted in2004-2006, as part of a larger project on low wage work in the Netherlands, which was part of a five country study for the Russell Sage Foundation, USA. In order to provide a background for understanding temporary agency work, recent developments in and ...

  17. Institutional Logics in Inter-institutional Temporary Organizations

    DEFF Research Database (Denmark)

    Pemsel, Sofia; Söderlund, Jonas

    -cognitive, normative, and regulative – are unfolding and evolving in such contexts. The case study addresses the integration and disintegration of logics and normative orders in an ongoing process characterized by the co-mingling, co-existence, creation and resolutions of hybrid logics and creation of institutional...... exceptions throughout the life of the studied temporary organization. In that respect, this paper contributes with a more nuanced view on the evolution, dynamics, and co-existence of pressures from multiple institutional demands at the organizational level....

  18. Regenerating 'Østre Havn' - The Everyday of Temporary Use Strategies

    DEFF Research Database (Denmark)

    Olsen, Tina Vestermann; Mikkelsen, Jacob Bjerre

    2015-01-01

    The article taps into discussions on temporary uses as a place-producing and transformative tool. At ‘Østre Havn’, a former industrial harbour in Aalborg, on-going developments strive for mixtures of residences, business and leisure. As tools towards that end the site is currently the test bed...... for a wide range of temporary uses. These are taking place alongside construction activities. This sets boundaries for the temporary use activities while the proposed future outlined by the municipality and the developer is being established. The question is what happens at the level of the everyday, how...... is the temporary use strategy affecting and shaping the opportunities for the group of temporary use activists to create difference at the site? The article aims at answering this by depicting a real life process over a timespan of two years - mainly from the perspective of the group of temporary use activists...

  19. Medical Devices

    NARCIS (Netherlands)

    Verkerke, Gijsbertus Jacob; Mahieu, H.F.; Geertsema, A.A.; Hermann, I.F.; van Horn, J.R.; Hummel, J. Marjan; van Loon, J.P.; Mihaylov, D.; van der Plaats, A.; Schraffordt Koops, H.; Schutte, H.K.; Veth, R.P.H.; de Vries, M.P.; Rakhorst, G.; Shi, Donglu

    2004-01-01

    The development of new medical devices is a very time-consuming and costly process. Besides the time between the initial idea and the time that manufacturing and testing of prototypes takes place, the time needed for the development of production facilities, production of test series, marketing,

  20. Electrochemical device

    Science.gov (United States)

    Grimes, Patrick G.; Einstein, Harry; Bellows, Richard J.

    1988-01-12

    A tunnel protected electrochemical device features channels fluidically communicating between manifold, tunnels and cells. The channels are designed to provide the most efficient use of auxiliary power. The channels have a greater hydraulic pressure drop and electrical resistance than the manifold. This will provide a design with the optimum auxiliary energy requirements.

  1. Assistive Devices

    Science.gov (United States)

    If you have a disability or injury, you may use a number of assistive devices. These are tools, products or types of equipment that help you perform tasks and activities. They may help you move around, see, communicate, eat, or get ...

  2. Detection device

    Science.gov (United States)

    Smith, J.E.

    1981-02-27

    The present invention is directed to a detection device comprising: (1) an entrance chamber; (2) a central chamber; and (3) an exit chamber. The central chamber includes an ionizing gas, anode, and means for connecting the anode with an external power supply and pulse counter.

  3. 26 CFR 1.181-0T - Table of contents (temporary).

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 3 2010-04-01 2010-04-01 false Table of contents (temporary). 1.181-0T Section...-0T Table of contents (temporary). This section lists the table of contents for §§ 1.181-1T through 1... deduction allowed. § 1.181-2TElection (temporary). (a) Time and manner of making election. (b) Election by...

  4. Cooling device in thermonuclear device

    International Nuclear Information System (INIS)

    Honda, Tsutomu.

    1988-01-01

    Purpose: To prevent loss of cooling effect over the entire torus structure directly after accidental toubles in a cooling device of a thermonuclear device. Constitution: Coolant recycling means of a cooling device comprises two systems, which are alternately connected with in-flow pipeways and exit pipeways of adjacent modules. The modules are cooled by way of the in-flow pipeways and the exist pipeways connected to the respective modules by means of the coolant recycling means corresponding to the respective modules. So long as one of the coolant recycling means is kept operative, since every one other modules of the torus structure is still kept cooled, the heat generated from the module put therebetween, for which the coolant recycling is interrupted, is removed by means of heat conduction or radiation from the module for which the cooling is kept continued. No back-up emergency cooling system is required and it can provide high economic reliability. (Kamimura, M.)

  5. 45 CFR 170.490 - Sunset of the temporary certification program.

    Science.gov (United States)

    2010-10-01

    ... TECHNOLOGY HEALTH INFORMATION TECHNOLOGY STANDARDS, IMPLEMENTATION SPECIFICATIONS, AND CERTIFICATION CRITERIA AND CERTIFICATION PROGRAMS FOR HEALTH INFORMATION TECHNOLOGY Temporary Certification Program for HIT...

  6. Defining chemical status of a temporary Mediterranean River.

    Science.gov (United States)

    Skoulikidis, Nikolaos Th

    2008-07-01

    Although the majority of rivers and streams in the Mediterranean area are temporary, no particular attention is being paid for such systems in the Water Framework Directive (WFD). A typical temporal Mediterranean river, draining an intensively cultivated basin, was assessed for its chemical status. Elevated concentrations of nitrates and salts in river water as well as nutrients and heavy metals in river sediments have been attributed to agricultural land uses and practices and point sources of organic pollution. A scheme for the classification of the river's chemical status (within the ecological quality classification procedure) was applied by combining pollution parameters in groups according to related pressures. In light of the temporal hydrological regime and anthropogenic impacts, sediment chemical quality elements were considered, in addition to hydrochemical ones. Despite the extensive agricultural activities in the basin, the majority of the sites examined showed a good quality and only three of them were classified as moderate. For the classification of the chemical quality of temporary water bodies, there is a need to develop ecologically relevant salinity and sediment quality standards.

  7. Tolerance of herbaceous summer legumes of temporary waterlogging

    Directory of Open Access Journals (Sweden)

    Elsa M. Ciotti

    2014-09-01

    Full Text Available A greenhouse study to evaluate adaptation of 4 herbaceous summer legumes to temporary waterlogging was conducted.  Species evaluated were Desmanthus virgatus and Aeschynomene americana in their vegetative stage, and Macroptilium lathyroides and M. atropurpureum in both vegetative and reproductive stages.  The experimental design was randomized blocks with 5 replications and treatments were:  T0, control; T1, saturation by capillary movement placing pots in buckets of 5 L with 10 cm of permanent water; and T2, flooding, placing pots in buckets of 10 L and a layer of water 5 cm above the soil.  The duration of the water treatments was 7 days. Waterlogging did not affect shoot or root biomass production nor nodulation in A. americana, whereas D. virgatus had its highest dry matter production in saturated soil (T1.  In M. lathyroides flooding tolerance was more evident in the reproductive than in the vegetative stage, probably due to more production of adventitious roots and formation of aerenchymatic tissue.  Macroptilium atropurpureum showed adaptation to temporary flooding.  Survival and quick recovery of these species would confirm their potential as forages for temporarily waterlogged soils.Keywords: Forage legumes, flooding, Aeschynomene americana, Desmanthus virgatus, Macroptilium lathyroides, Northeast Argentina.DOI: 10.17138/TGFT(2278-286

  8. The profound precariousness of work through temporary work agency

    Directory of Open Access Journals (Sweden)

    Mihaela-Emilia Marica

    2016-12-01

    Full Text Available The increase in the number of atypical work contracts in the field of industry relationships, as part of a major European trend towards gaining more flexibility in the labour market, is significant and cannot be overlooked in most member countries of the European Union. This finding is corroborated by the recent surveys conducted across Europe, that reveal the prevalence of these flexible ways of organizing work, over the archetypal template of the individual work contract. However, this range of atypical contractual arrangements and the great number of versions and subcategories they include, are describing a number of negative features that seem to characterize these new forms of employment. Since the field of atypical employment is complex and we cannot analyse the incidence of these negative effects for all the atypical methods of employment, in the following article we will limit ourselves to explore the pressing issues related to the system of temporary work through work agencies. As we shall see, all aspects of the salary field, of health and safety at work and the level of insecurity and instability of labour through temporary work agency reveals a strong character associated with this kind of precarious employment.

  9. Temporary endoscopic metallic stent for idiopathic esophageal achalasia.

    Science.gov (United States)

    Coppola, Franco; Gaia, Silvia; Rolle, Emanuela; Recchia, Serafino

    2014-02-01

    Idiopathic achalasia is a motor disorder of the esophagus of unknown etiology caused by loss of motor neurons determining an altered motility. It may determine severe symptoms such as progressive dysphagia, regurgitations, and pulmonary aspirations. Many therapeutic options may be offered to patients with achalasia, from surgery to endoscopic treatments such as pneumatic dilation, botulinum injection, peroral endoscopic myotomy, or endoscopic stenting. Recently, temporary placement of a stent was proposed by Cheng as therapy for achalasia disorders, whereas no Western authors have dealt with it up to date. The present study reports our preliminary experience in 7 patients with achalasia treated with a temporary stent. Partially covered self-expanding metallic stents (Micro-Tech, Nanjin, China) 80 mm long and 30 mm wide were placed under fluoroscopic control and removed after 6 days. Clinical follow-up was scheduled to check endoscopic success, symptoms release, and complications. The placement and the removal of the stents were obtained in all patients without complications. Mean clinical follow-up was 19 months. Five out of 7 patients referred total symptoms release and 2 experienced significant improvement of dysphagia. The procedure was not time consuming and was safe; no mild or severe complications were registered. In conclusion, our results may suggest a possible safe and effective endoscopic alternative treatment in patients with achalasia; however, further larger studies are necessary to confirm these promising, but very preliminary, data.

  10. Temporary work and depressive symptoms in South Korean workers.

    Science.gov (United States)

    Kim, W; Kim, T-H; Lee, T-H; Ju, Y J; Chun, S Y; Park, E-C

    2017-08-01

    In many countries, including South Korea, labour market changes have led to an increase in unstable, temporary jobs. There is evidence that workers in such jobs may experience poorer mental health than those in more stable employment. To investigate the association between temporary employment and depressive symptoms in South Korean workers. We analysed data from the 2010-2014 Korean Welfare Panel Study (KOWEPS). Employment type was categorized into workers paid per day of labour (day labourers), those on short-term contracts (fixed-term workers) and permanent workers. The association between employment type and depressive symptoms, measured using the Center for Epidemiological Studies Depression scale (CES-D 11), was examined using the generalized estimating equation model. A total of 3756 workers aged 20-59 were included in the 2010 baseline population. Day labourers had the highest mean CES-D 11 score, followed by fixed-term workers and permanent workers. With the day labourer group as reference, fixed-term workers (β: -1.5027, P < 0.001) and permanent workers (β: -2.1848, P < 0.001) showed statistically significant decreases in depression scores. Compared with day labourers, fixed-term workers and permanent workers had progressively lower depression scores. The findings of this study suggest that mental health inequalities based on employment type exist in South Korea. © The Author 2017. Published by Oxford University Press on behalf of the Society of Occupational Medicine. All rights reserved. For Permissions, please email: journals.permissions@oup.com

  11. Device Design and Test of Fatigue Behaviour of Expansion Anchor Subjected to Tensile Loads

    Directory of Open Access Journals (Sweden)

    Zhang Jinfeng

    2016-01-01

    Full Text Available In order to study on the fatigue behaviour of expansion anchor (M16, grade 8.8 for overhead contact system in electrification railways, a set of safe, practical loading device is designed and a fatigue test campaign was carried out at structural laboratory of China Academy of Building Research on expansion anchor embedded in concrete block. The mobile frame of the loading device was designed well by finite-element simulation. According to some fatigue performance test of expansion anchor with different size and form, the device have been assessed experimentally its dependability. The results were found that no fatigue damage phenomenon occurred in all specimens after 2×106 cycles tensile fatigue test in this specific series. It shows that in the condition of medium level or slightly lower maximum stress limit and nominal stress range, expansion bolt has good fatigue resistance. The biggest relative displacement and the residual relative displacement after test (Δδ = δ2-δ1 was also strongly lower than the symbol of the fatigue test failure index of this specific series (0.5mm in the high cycle fatigue regime. The ultimate tension failures mode after fatigue tests in all tested samples take place in the concrete anchorage zone. The reduction range of the ultimate tensile strength properties of the anchorage system was not obvious, and the concrete was seen to be the weakest link of the system.

  12. Thermonuclear device

    International Nuclear Information System (INIS)

    Tezuka, Masaru.

    1993-01-01

    Protrusions and recesses are formed to a vacuum vessel and toroidal magnetic coils, and they are engaged. Since the vacuum vessel is generally supported firmly by a rack or the like by support legs, the toroidal magnetic field coils can be certainly supported against tumbling force. Then, there can be attained strong supports for the toroidal magnetic field coils, in addition to support by wedges on the side of inboard and support by share panels on the side of outboard, capable of withstanding great electromagnetic forces which may occur in large-scaled next-generation devices. That is, toroidal magnetic field coils excellent from a view point of deformation and stress can be obtained, to provide a thermonuclear device of higher reliability. (N.H.)

  13. Thermonuclear device

    International Nuclear Information System (INIS)

    Oosaki, Osamu; Masuda, Kenju.

    1980-01-01

    Purpose: To provide excellent electric properties and high reliability in a thermonuclear device by improving a current collecting board connected to a coil device. Constitution: A current collecting board element perforated with an opening for enserting a connecting terminal is sized to be inserted into a plating tank, and is surface treated in the plating tank. Only the current collecting board element preferably surface treated is picked up. A plurality of such current collecting board elements are connected and welded to form a large current collecting board. In this manner, the current collecting board having several m 2 to several ten order m 2 in area can be obtained as preferably surface treated at the connecting terminal hole. The current collecting board element can be determined in shape with the existing facility without increasing the size of a surface treating tank. (Kamimura, M.)

  14. Thermonuclear device

    International Nuclear Information System (INIS)

    Yagi, Yasuomi; Takahashi, Ken; Hashimoto, Hiroshi.

    1984-01-01

    Purpose: To improve the plasma confining performances by bringing the irregular magnetic fields nearly to zero and decreasing the absolute value of the irregular magnetic fields at every positions. Constitution: The winding direction of a plurality of coil elements, for instance, double pan cake coils of toroidal coils in a torus type or mirror type thermonuclear device are reversed to each other in their laminating direction, whereby the irregular magnetic fields due to the coil-stepped portions in each toroidal coils are brought nearly to zero. This enables to bring the average irregular magnetic fields as a whole in the thermonuclear device nearly to zero, as well as, decrease the absolute value of the irregular magnetic fields in each positions. Thus, the plasma confining performances can be improved. (Moriyama, K.)

  15. "Distinvar" device

    CERN Multimedia

    CERN PhotoLab

    1965-01-01

    The alignment of one of the accelerator magnets being checked by the AR Division survey group. A "distinvar" device, invented by the group, using calibrated invar wires stretched between the fixed survey pillar (on the left) and a fixed point on the magnet. In two days it is thus possible to measure the alignment of the 100 magnets with an accuracy better than 1/10.

  16. Latching device

    Science.gov (United States)

    Ulrich, G. W. (Inventor)

    1975-01-01

    A latching device is suited for use in establishing a substantially motionless connection between a stationary receiver and a movable latching mechanism. The latching mechanism includes a pivotally supported restraining hook continuously urged into a capturing relationship with the receiver, characterized by a spring-biased pawl having a plurality of aligned teeth. The teeth are seated in the surface of the throat of the hook and positionable into restraining engagement with a rigid restraining shoulder projected from the receiver.

  17. Estimating temporary emigration and breeding proportions using capture-recapture data with Pollock's robust design

    Science.gov (United States)

    Kendall, W.L.; Nichols, J.D.; Hines, J.E.

    1997-01-01

    Statistical inference for capture-recapture studies of open animal populations typically relies on the assumption that all emigration from the studied population is permanent. However, there are many instances in which this assumption is unlikely to be met. We define two general models for the process of temporary emigration, completely random and Markovian. We then consider effects of these two types of temporary emigration on Jolly-Seber (Seber 1982) estimators and on estimators arising from the full-likelihood approach of Kendall et al. (1995) to robust design data. Capture-recapture data arising from Pollock's (1982) robust design provide the basis for obtaining unbiased estimates of demographic parameters in the presence of temporary emigration and for estimating the probability of temporary emigration. We present a likelihood-based approach to dealing with temporary emigration that permits estimation under different models of temporary emigration and yields tests for completely random and Markovian emigration. In addition, we use the relationship between capture probability estimates based on closed and open models under completely random temporary emigration to derive three ad hoc estimators for the probability of temporary emigration, two of which should be especially useful in situations where capture probabilities are heterogeneous among individual animals. Ad hoc and full-likelihood estimators are illustrated for small mammal capture-recapture data sets. We believe that these models and estimators will be useful for testing hypotheses about the process of temporary emigration, for estimating demographic parameters in the presence of temporary emigration, and for estimating probabilities of temporary emigration. These latter estimates are frequently of ecological interest as indicators of animal movement and, in some sampling situations, as direct estimates of breeding probabilities and proportions.

  18. A comparison of lower canine retraction and loss of anchorage between conventional and self-ligating brackets: a single-center randomized split-mouth controlled trial.

    Science.gov (United States)

    da Costa Monini, André; Júnior, Luiz Gonzaga Gandini; Vianna, Alexandre Protásio; Martins, Renato Parsekian

    2017-05-01

    To evaluate the rate of lower canine retraction, anchorage loss, and changes on lower canines and first molars axial inclination using self-ligating and conventional brackets. Twenty-five adult patients with a treatment plan involving extractions of four first premolars were selected for this split-mouth trial and had either conventional or self-ligating brackets bonded to lower canines in a block randomization. Retraction was accomplished using 100-g nickel titanium closed-coil springs, which were reactivated each 4 weeks. Oblique radiographs were taken before and after total canine retraction and the cephalograms were superimposed on stable structures of the mandible. Cephalometric points were digitized twice by a single-blinded operator for error control and the average of the points were used to determine the following variables: canine cusp horizontal changes, molar cusp horizontal changes, and angulation changes in canines and molars. Paired t tests were used to analyze the blinded data for group differences. All patients reached final phase without bracket debonds. No differences were found between the two groups for all variables tested. No serious harm was observed. Both brackets showed the same rate of canine retraction and loss of anteroposterior anchorage of the molars. No changes were found between brackets regarding the inclination of canines and first molars. Using self-ligating brackets to retract lower canines will not increase the velocity of tooth movement, does not increase anchorage, and does not decrease tipping.

  19. Chlamydia induces anchorage independence in 3T3 cells and detrimental cytological defects in an infection model.

    Directory of Open Access Journals (Sweden)

    Andrea E Knowlton

    Full Text Available Chlamydia are gram negative, obligate intracellular bacterial organisms with different species causing a multitude of infections in both humans and animals. Chlamydia trachomatis is the causative agent of the sexually transmitted infection (STI Chlamydia, the most commonly acquired bacterial STI in the United States. Chlamydial infections have also been epidemiologically linked to cervical cancer in women co-infected with the human papillomavirus (HPV. We have previously shown chlamydial infection results in centrosome amplification and multipolar spindle formation leading to chromosomal instability. Many studies indicate that centrosome abnormalities, spindle defects, and chromosome segregation errors can lead to cell transformation. We hypothesize that the presence of these defects within infected dividing cells identifies a possible mechanism for Chlamydia as a cofactor in cervical cancer formation. Here we demonstrate that infection with Chlamydia trachomatis is able to transform 3T3 cells in soft agar resulting in anchorage independence and increased colony formation. Additionally, we show for the first time Chlamydia infects actively replicating cells in vivo. Infection of mice with Chlamydia results in significantly increased cell proliferation within the cervix, and in evidence of cervical dysplasia. Confocal examination of these infected tissues also revealed elements of chlamydial induced chromosome instability. These results contribute to a growing body of data implicating a role for Chlamydia in cervical cancer development and suggest a possible molecular mechanism for this effect.

  20. Tips for the fabrication of temporary tritium experiments

    International Nuclear Information System (INIS)

    Binning, K.E.; Jenkins, E.M.

    1988-01-01

    The Tritium System Test Assembly (TSTA) is a facility built for the demonstration of tritium handling systems necessary for tritium-burning fusion reactors. The facility has been in operation handling tritium for four years. The current inventory of tritium is approximately one hundred grams, with DOE approval for a maximum inventory of two hundred grams. Not all experiments performed at TSTA require the operation of the main process loop. During the last four years, many small scale experiments have been performed to test the compatibility and operation of tritium processing components in small self-contained experimental packages. These packages are fabricated inside secondary containment gloveboxes and can be operated for hours or months with little monitoring. Construction of these packages need to be tritium compatible, inexpensive, easy to build, and versatile. This paper discusses some of the problems and remedies encountered during the building of temporary experiments

  1. Temporary threshold shift after exposure to pop music.

    Science.gov (United States)

    Axelsson, A; Lindgren, F

    1978-01-01

    Temporary threshold shift (TTS) was studied in pop musicians as well as in listeners. It appears that TTS is less pronounced in pop musicians than in listeners. This can only in part be explained by slightly inferior hearing threshold levels than in the audience before exposure. Further, male listeners showed more TTS than female listeners. After 2 hours of exposure to live pop music a TTS2 appears in pop musicians after an exposure to 98 dB(A) as opposed to listeners where TTS2 appears at 92 dB(A). When the present results are related to the CHABA risk criteria it seems that exposure to live pop music at 100 dB(A) for 2 hours is a limit which should not be exceeded if the risk of permanent hearing loss is to be avoided.

  2. Temporary services for patients in need of chronic care

    DEFF Research Database (Denmark)

    Hesse, Morten

    2008-01-01

    Background A project is a temporary endeavour undertaken to create a product or service. Projects are frequently used for the testing and development of new approaches in social work. Projects can receive grants from central, often national or international institutions, and allow for more...... experimentation than work placed within existing institutions. Discussion For socially marginalized groups who need continuing support and care, receiving help in a project means that the clients will have to be transferred to other services when the project ends. There is also a risk that clients will experience...... a decline in services, as staff members have to seek new employment towards the end of the project, or begin to focus more on the evaluation than the services. This raises some ethical issues concerning the use of human subjects in projects. Conclusion Project managers should consider ethical issues...

  3. Cultivating and Benefiting from Member Familiarity in Temporary Work Groups

    DEFF Research Database (Denmark)

    Hessel, Shannon

    In this paper, I investigate an example of short-duration, time-bound project work conducted by high-performing groups in order to surprise our expectations regarding the motivations and potential to cooperate and to cultivate group member familiarity within such temporary organizations. Project...... limited time and a perceived short shadow of the future. Several contributions result: First, I challenge our expectation that a short shadow of the future will decrease the likelihood of cooperation by demonstrating how the clan-like tendency to construct common values and aspirations motivated...... cooperative behavior in these groups. Second, I challenge our expectation that a task-oriented over relationship-oriented approach will inevitably dominate work when projects are time-bound and of short duration by describing moments in which these groups chose relationship-oriented activities despite time...

  4. Temporary and circular labour migration and codevelpment: a case estudy

    Directory of Open Access Journals (Sweden)

    Elena Sánchez-Montijano

    2012-05-01

    Full Text Available The search for new ways to manage international migration is one of the main topics at the current political agendas. Within this framework, Temporary and Circular Labour Migration (TCLM as a way of fl ow management on the one hand, and co-development as a set of actions that seek to articulate migration and development on the other, have recently been promoted as double win situations. Both initiatives depart from the assumption that migrants can make important contributions to development, in their countries of destination but also in their countries of origin. The paper explores the opportunities and difficulties that arise when a single initiative attempts tobring together these two types of activities, which have so far been managed by different entities and in separated venues. The study raises the question about the positive and negative effects of this alliance. The article presents the results of a TCLM case study.

  5. Tips for the fabrication of temporary tritium experiments

    International Nuclear Information System (INIS)

    Binning, K.E.; Jenkins, E.M.

    1988-01-01

    The Tritium System Test Assembly (TSTA) is a facility built for the demonstration of tritium handling systems necessary for tritium-burning fusion reactors. The facility has been in operation handling tritium for four years. The current inventory of tritium is approximately one hundred grams with DOE approval exists for a maximum inventory of two hundred grams. Not all experiments performed at TSTA require the operation of the main process loop. During the last four years, many small scale experiments have been performed to test the compatibility and operation of tritium processing components in small self-contained experimental packages. These packages are fabricated inside secondary containment gloveboxes and can be operated for hours or months with little monitoring. Construction of these packages need to be tritium compatible, inexpensive, easy to build, and versatile. This paper discusses some of the problems and remedies encountered during the building of temporary experiments

  6. 77 FR 31183 - Safety Zone, Temporary Change for Recurring Fireworks Display Within the Fifth Coast Guard...

    Science.gov (United States)

    2012-05-25

    ...-AA00 Safety Zone, Temporary Change for Recurring Fireworks Display Within the Fifth Coast Guard District, Pamlico River and Tar River; Washington, NC AGENCY: Coast Guard, DHS. ACTION: Temporary final... is intended to restrict vessel traffic in a portion of the Pamlico River and Tar River near...

  7. 78 FR 23952 - Notice of Temporary Closure on Public Lands in Elmore County, ID

    Science.gov (United States)

    2013-04-23

    ...] Notice of Temporary Closure on Public Lands in Elmore County, ID AGENCY: Bureau of Land Management, Interior. ACTION: Notice of temporary closure. SUMMARY: Notice is hereby given that the Stout Fire closure to motorized vehicle use is in effect on public lands administered by the Four Rivers Field Office...

  8. 77 FR 14417 - Notice of Temporary Closure on Public Lands in Gooding and Elmore Counties, ID

    Science.gov (United States)

    2012-03-09

    ...] Notice of Temporary Closure on Public Lands in Gooding and Elmore Counties, ID AGENCY: Bureau of Land Management, Interior. ACTION: Notice of temporary closure. SUMMARY: Notice is hereby given that the Blair Fire closure to motorized vehicle use is in effect on public lands administered by the Four Rivers and...

  9. 77 FR 35855 - Safety Zone, Temporary Change for Recurring Fifth Coast Guard District Fireworks Displays...

    Science.gov (United States)

    2012-06-15

    ... 1625-AA00 Safety Zone, Temporary Change for Recurring Fifth Coast Guard District Fireworks Displays; Northwest Harbor (East Channel) and Tred Avon River, MD AGENCY: Coast Guard, DHS. ACTION: Temporary final... Channel), Patapsco River, and Tred Avon River during the event. DATES: This rule is effective from 8 p.m...

  10. 78 FR 20135 - Notice of Temporary Closure on Public Lands in Boise County, ID

    Science.gov (United States)

    2013-04-03

    ...] Notice of Temporary Closure on Public Lands in Boise County, ID AGENCY: Bureau of Land Management, Interior. ACTION: Notice of Temporary Closure SUMMARY: Notice is hereby given that the Springs Fire closure to all human use is in effect on public lands administered by the Four Rivers Field Office, Bureau of...

  11. Do changes in regulation affect employment duration in temporary help agencies?

    DEFF Research Database (Denmark)

    Antoni, Manfred; Jahn, Elke

    2009-01-01

    The employment duration of workers in temporary help agencies is seen as an important indicator of their job quality. Most of the countries that regulate temporary agency employment do so to insure at least a minimal level of employment stability. Over the past three decades Germany has repeatedly...

  12. 20 CFR 655.1301 - Applications for temporary employment certification in agriculture.

    Science.gov (United States)

    2010-04-01

    ... 20 Employees' Benefits 3 2010-04-01 2010-04-01 false Applications for temporary employment certification in agriculture. 655.1301 Section 655.1301 Employees' Benefits EMPLOYMENT AND TRAINING... Applications for temporary employment certification in agriculture. (a) Application filing requirements. (1) An...

  13. Temporary contracts : Effect on job satisfaction and personal lives of recent PhD graduates

    NARCIS (Netherlands)

    Waaijer, C.J.F.; Belder, R.; Sonneveld, H.; Van, Bochove C.A.; Van, der Weijden I.C.M.

    2017-01-01

    In this study, we assess the effects of temporary employment on job satisfaction and the personal lives of recent PhD graduates. Temporary employment is becoming increasingly prevalent in many sectors, but has been relatively common in academia, especially for early career scientists. Labor market

  14. 26 CFR 1.103(n)-6T - Determinations of population (temporary).

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 2 2010-04-01 2010-04-01 false Determinations of population (temporary). 1.103....103(n)-6T Determinations of population (temporary). Q-1: What is the proper method for determining population? A-1: All determinations of population must be made with respect to any calendar year on the basis...

  15. Ripening of clayey dredged sediments during temporary upland disposal, A Bioremediation technique.

    NARCIS (Netherlands)

    Vermeulen, J.; Grotenhuis, J.T.C.; Joziasse, J.; Rulkens, W.H.

    2003-01-01

    Background and Goal. In the Netherlands about 40 million m3 of sediment has to be dredged annually for both maintenance and environmental reasons. Temporary upland disposal is the most widely adopted alternative for dredged sediments worldwide. For good management of temporary disposal sites,

  16. 30 CFR 816.14 - Casing and sealing of drilled holes: Temporary.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 3 2010-07-01 2010-07-01 false Casing and sealing of drilled holes: Temporary. 816.14 Section 816.14 Mineral Resources OFFICE OF SURFACE MINING RECLAMATION AND ENFORCEMENT...-SURFACE MINING ACTIVITIES § 816.14 Casing and sealing of drilled holes: Temporary. Each exploration hole...

  17. 76 FR 78739 - Agency Information Collection (Regulation on Application for Fisher Houses and Other Temporary...

    Science.gov (United States)

    2011-12-19

    ... DEPARTMENT OF VETERANS AFFAIRS [OMB Control No. 2900-0630] Agency Information Collection (Regulation on Application for Fisher Houses and Other Temporary Lodging and VHA Fisher House Application... INFORMATION: Title: Regulation on Application for Fisher Houses and Other Temporary Lodging and VHA Fisher...

  18. 76 FR 63355 - Proposed Information Collection (Regulation on Application for Fisher Houses and Other Temporary...

    Science.gov (United States)

    2011-10-12

    ... (Regulation on Application for Fisher Houses and Other Temporary Lodging and VHA Fisher House Application... information technology. Title: Regulation on Application for Fisher Houses and Other Temporary Lodging and VHA Fisher House Application, VA Forms 10-0408 and 10-0408a. OMB Control Number: 2900-0630. Type of Review...

  19. Designing Temporary Systems: Exploring Local School Improvement Intentions in the Swedish Context

    Science.gov (United States)

    Nordholm, Daniel; Blossing, Ulf

    2014-01-01

    This article targets local school improvement in Sweden and temporary systems as a model to organize improvement work. These data are based on a qualitative case study of teacher groups constituting a temporary system representing the different subjects in comprehensive school in a medium-sized urban municipality. A total of eight interviews were…

  20. 8 CFR 1244.5 - Temporary treatment benefits for eligible aliens.

    Science.gov (United States)

    2010-01-01

    ... 8 Aliens and Nationality 1 2010-01-01 2010-01-01 false Temporary treatment benefits for eligible aliens. 1244.5 Section 1244.5 Aliens and Nationality EXECUTIVE OFFICE FOR IMMIGRATION REVIEW, DEPARTMENT... § 1244.5 Temporary treatment benefits for eligible aliens. (a) Prior to the registration period. Prior to...

  1. 75 FR 6883 - Temporary Agricultural Employment of H-2A Aliens in the United States

    Science.gov (United States)

    2010-02-12

    ... Division 29 CFR Part 501 Temporary Agricultural Employment of H-2A Aliens in the United States; Final Rule... Division 29 CFR Part 501 RIN 1205-AB55 Temporary Agricultural Employment of H-2A Aliens in the United... of the alien in such labor or services will not adversely affect the wages and working conditions of...

  2. 19 CFR 210.69 - Approval of complainant's temporary relief bond.

    Science.gov (United States)

    2010-04-01

    ... 19 Customs Duties 3 2010-04-01 2010-04-01 false Approval of complainant's temporary relief bond. 210.69 Section 210.69 Customs Duties UNITED STATES INTERNATIONAL TRADE COMMISSION INVESTIGATIONS OF UNFAIR PRACTICES IN IMPORT TRADE ADJUDICATION AND ENFORCEMENT Temporary Relief § 210.69 Approval of...

  3. 20 CFR 416.1149 - What is a temporary absence from your living arrangement.

    Science.gov (United States)

    2010-04-01

    ... SECURITY INCOME FOR THE AGED, BLIND, AND DISABLED Income Temporary Absence § 416.1149 What is a temporary... under age 22, you are temporarily absent while you are away at school, regardless of how long you are... provided in school regulations). (ii) However, if you are a child under age 18, and your permanent living...

  4. 77 FR 4623 - Wheego Electric Cars, Inc. Receipt of Petition for Temporary Exemption From the Electronic...

    Science.gov (United States)

    2012-01-30

    ...-0013] Wheego Electric Cars, Inc. Receipt of Petition for Temporary Exemption From the Electronic.... SUMMARY: In accordance with the procedures in 49 CFR part 555, Wheego Electric Cars, Inc., has petitioned... Electric Cars, Inc. (Wheego) submitted a petition dated August 15, 2011 asking the agency for a temporary...

  5. 77 FR 47915 - Wheego Electric Cars, Inc.; Grant of Petition for Temporary Exemption From the Electronic...

    Science.gov (United States)

    2012-08-10

    ...-0013] Wheego Electric Cars, Inc.; Grant of Petition for Temporary Exemption From the Electronic.... SUMMARY: This notice grants the petition of Wheego Electric Cars, Inc. (Wheego) for the temporary... procedures in 49 CFR part 555, Wheego Electric Cars, Inc. (Wheego) submitted a petition dated August 15, 2011...

  6. 76 FR 43376 - Order Granting Temporary Exemptions From Certain Government Securities Act Provisions and...

    Science.gov (United States)

    2011-07-20

    .../gsareg.htm . As noted in its request, on July 16, 2011, ICE Trust reorganized its corporate structure... DEPARTMENT OF THE TREASURY Order Granting Temporary Exemptions From Certain Government Securities... temporary exemptions from certain Government Securities Act of 1986 provisions and regulations regarding...

  7. 26 CFR 1.892-6T - Income of international organizations (temporary regulations).

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES Miscellaneous Provisions § 1.892-6T Income of international organizations (temporary regulations). (a) Exempt from tax. Subject to the provisions of section 1 of the... 26 Internal Revenue 9 2010-04-01 2010-04-01 false Income of international organizations (temporary...

  8. 5 CFR 300.503 - Conditions for using private sector temporaries.

    Science.gov (United States)

    2010-01-01

    ... 5 Administrative Personnel 1 2010-01-01 2010-01-01 false Conditions for using private sector... REGULATIONS EMPLOYMENT (GENERAL) Use of Private Sector Temporaries § 300.503 Conditions for using private... help service firm for the brief or intermittent use of the skills of private sector temporaries, when...

  9. 38 CFR 21.6001 - Temporary vocational training program for certain pension recipients.

    Science.gov (United States)

    2010-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 2 2010-07-01 2010-07-01 false Temporary vocational training program for certain pension recipients. 21.6001 Section 21.6001 Pensions, Bonuses, and Veterans... Program of Vocational Training for Certain New Pension Recipients General § 21.6001 Temporary vocational...

  10. 26 CFR 301.7701-2T - Business entities; definitions (temporary).

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 18 2010-04-01 2010-04-01 false Business entities; definitions (temporary). 301... (CONTINUED) PROCEDURE AND ADMINISTRATION PROCEDURE AND ADMINISTRATION Definitions § 301.7701-2T Business entities; definitions (temporary). (a) through (c)(2)(ii) [Reserved] For further guidance, see § 301.7701-2...

  11. 19 CFR 12.104f - Temporary disposition of materials and articles.

    Science.gov (United States)

    2010-04-01

    ... 19 Customs Duties 1 2010-04-01 2010-04-01 false Temporary disposition of materials and articles... SECURITY; DEPARTMENT OF THE TREASURY SPECIAL CLASSES OF MERCHANDISE Cultural Property § 12.104f Temporary... museum or other cultural or scientific institution in the U.S. if he finds that sufficient safeguards...

  12. 26 CFR 1.41-0T - Table of contents (temporary).

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 1 2010-04-01 2010-04-01 true Table of contents (temporary). 1.41-0T Section 1... Credits Against Tax § 1.41-0T Table of contents (temporary). This section lists the table of contents for...) Election. (1) In general. (2) Time and manner of election. (3) Revocation. (4) Special rules for controlled...

  13. 26 CFR 1.468A-1T - Nuclear decommissioning costs; general rules (temporary).

    Science.gov (United States)

    2010-04-01

    ... accrual method of accounting that do not elect the application of section 468A are not allowed a deduction... (temporary). 1.468A-1T Section 1.468A-1T Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE...-1T Nuclear decommissioning costs; general rules (temporary). (a) Introduction. Section 468A provides...

  14. 77 FR 76854 - Temporary Rule Regarding Principal Trades With Certain Advisory Clients

    Science.gov (United States)

    2012-12-31

    ... 3235-AL28 Temporary Rule Regarding Principal Trades With Certain Advisory Clients AGENCY: Securities... transactions with certain of their advisory clients. The amendment extends the date on which rule 206(3)- 3T... releases used RIN 3235-AJ96. (See Temporary Rule Regarding Principal Trades with Certain Advisory Clients...

  15. 17 CFR 274.404 - Form TH-Notification of reliance on temporary hardship exemption.

    Science.gov (United States)

    2010-04-01

    ... 17 Commodity and Securities Exchanges 3 2010-04-01 2010-04-01 false Form TH-Notification of... Forms for Electronic Filing § 274.404 Form TH—Notification of reliance on temporary hardship exemption. Form TH shall be filed by any electronic filer who submits to the Commission, pursuant to a temporary...

  16. 78 FR 20123 - Extension of the Designation of Honduras for Temporary Protected Status

    Science.gov (United States)

    2013-04-03

    ... Docket No. USCIS-2012-0016] RIN 1615-ZB18 Extension of the Designation of Honduras for Temporary... the designation of Honduras for Temporary Protected Status (TPS) for 18 months from July 6, 2013... Honduras that prompted the TPS designation continue to be met. There continues to be a substantial, but...

  17. 26 CFR 1.61-2T - Taxation of fringe benefits-1985 through 1988 (temporary).

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 2 2010-04-01 2010-04-01 false Taxation of fringe benefits-1985 through 1988 (temporary). 1.61-2T Section 1.61-2T Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY..., and Taxable Income § 1.61-2T Taxation of fringe benefits—1985 through 1988 (temporary). (a) Fringe...

  18. 26 CFR 1.6031(b)-2T - REMIC reporting requirements (temporary). [Reserved

    Science.gov (United States)

    2010-04-01

    ... requirements (temporary). [Reserved] ... 26 Internal Revenue 13 2010-04-01 2010-04-01 false REMIC reporting requirements (temporary). [Reserved] 1.6031(b)-2T Section 1.6031(b)-2T Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE...

  19. 75 FR 4626 - Order Granting a Temporary Exemption From Certain Government Securities Act Provisions and...

    Science.gov (United States)

    2010-01-28

    ... DEPARTMENT OF THE TREASURY Order Granting a Temporary Exemption From Certain Government Securities... Department of the Treasury (Treasury) is issuing a temporary exemption from certain Government Securities Act... accommodate customer clearing of credit default swaps that reference government securities. Treasury is also...

  20. Assessment of the consequences in premature loss of the temporary lower molars.

    Science.gov (United States)

    Petcu, Ana; Bălan, Adriana; Gavrilă, Laura Maria Vasilca; Savin, Carmen

    2014-01-01

    The consequences of premature loss of temporary teeth are complex, both of functional and morphological order and the clinical presentation depends on multiple factors: the temporary tooth loss rate as compared with permanent tooth eruption sequence and the number and topography of teeth extracted, so the clinical form of edentulous, which can be frontal or lateral, symmetric or asymmetric, isolated or continuous.

  1. 76 FR 60124 - Tesla Motors, Inc.; Grant of Petition for Temporary Exemption From the Electronic Stability...

    Science.gov (United States)

    2011-09-28

    ...-0110] Tesla Motors, Inc.; Grant of Petition for Temporary Exemption From the Electronic Stability... notice grants the petition of Tesla Motors, Inc. (Tesla) for the temporary exemption of its Roadster... procedures in 49 CFR Part 555, Tesla Motors, Inc. (Tesla) submitted a petition dated June 7, 2011 asking the...

  2. 26 CFR 1.6045-1T - Returns of information of brokers and barter exchanges (temporary).

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 13 2010-04-01 2010-04-01 false Returns of information of brokers and barter exchanges (temporary). 1.6045-1T Section 1.6045-1T Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF... of information of brokers and barter exchanges (temporary). (a)-(k) [Reserved] For further guidance...

  3. 26 CFR 1.163-11T - Allocation of certain prepaid qualified mortgage insurance premiums (temporary).

    Science.gov (United States)

    2010-04-01

    ... insurance premiums (temporary). 1.163-11T Section 1.163-11T Internal Revenue INTERNAL REVENUE SERVICE... insurance premiums (temporary). (a) Allocation—(1) In general. As provided in section 163(h)(3)(E), premiums... section applies whether the qualified mortgage insurance premiums are paid in cash or are financed...

  4. 30 CFR 75.209 - Automated Temporary Roof Support (ATRS) systems.

    Science.gov (United States)

    2010-07-01

    ... of temporary support shall be used, as specified in the roof control plan, when— (1) Mining... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Automated Temporary Roof Support (ATRS) systems... COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Roof Support § 75.209...

  5. Damping device

    International Nuclear Information System (INIS)

    Banks, E.L. Jr.; Dowell, T.P.

    1976-01-01

    The description is given of a damper which includes a pair of telescopic components interconnected by relative linear movement one in relation to the other, by a screw and ball nut device, with a braking surface on one of the components, a brake engaging the braking surface, an inertia mass entrained by the other components, non-deformable and distinct brake actuating gear, independently mobile in relation to the other braking system and fixed and controlled by the inertia mass, positively to engage the braking surface. This damper is for retaining the parts of a nuclear power station so that can withstand earthquakes [fr

  6. Thermonuclear device

    International Nuclear Information System (INIS)

    Inoue, Toyokazu; Murata, Toru.

    1983-01-01

    Purpose: To shield superconducting coils for use in the generation of magnetic field against neutron irradiation thereby preventing tritium contamination. Constitution: The thermonuclear device comprises, in its inside, a vacuum container for containing plasmas, superconducting coils disposed to the outside of the vacuum container and neutron absorbers disposed between the super-conducting coils and the vacuum container. since neutrons issued from the plasma are absorbed by neutron absorbers and not irradiated to the superconducting coils, generation of tritium due to the reaction between 3 He in the liquid helium as the coolants for the super-conducting coils and the neutrons is prevented. (Aizawa, K.)

  7. Strainer device

    International Nuclear Information System (INIS)

    Mokuya, Kenji.

    1975-01-01

    Object: To provide a strainer device, which is adapted to facilitate flushing and is particularly suited for installation in the cooling system of a liquid metal cooled fast breeding reactor. Structure: A casing accommodating a strainer and a blind plate for the selection of a flow path is provided at a suitable portion of the duct line. The blind plate is adapted to be rotated by an opening and closing means consisting of a rod. bellows, shaft and so forth. At the time of flushing, the duct line is sealed by the blind plate. (Nakamura, S.)

  8. Temporary ectropion therapy by adhesive taping: a case study

    Directory of Open Access Journals (Sweden)

    Habermann Anke

    2008-07-01

    Full Text Available Abstract Introduction Various surgical procedures are available to correct paralytic ectropion, which are applied in irreversible facial paresis. Problems occur when facial paresis has an unclear prognosis, since surgery of the lower eyelid is usually irreversible. We propose a simple method to correct temporary ectropion in facial palsy by applying an adhesive strip. Patients and methods Ten patients with peripheral facial paresis and paralytic ectropion were treated with an adhesive strip to correct paralytic ectropion. We used "Steri-Strips" (45 × 6.0 mm, which were taped on the carefully cleaned skin of the lower eyelid and of the adjacent zygomatic region until the prognosis of the paresis was clarified. In addition to the examiner's evaluation of the lower lacrimal point in the lacrimal lake, subjective improvement of the symptoms was assessed using a visual analogue scale (VAS, 1–10. Results 9 patients reported a clear improvement of the symptoms after adhesive taping. There was a clear regression of tearing (VAS (median = 8; 1 = no improvement, 10 = very good improvement, the cosmetic impairment of the adhesive tape was low (VAS (median = 2.5; 1 = no impairment, 10 = severe impairment and most of the patients found the use of the adhesive strip helpful. There was slight reddening of the skin in one case and well tolerated by the facial skin in the other cases. Conclusion The cause and location of facial nerve damage are decisive for the type of surgical therapy. In potentially reversible facial paresis, procedures should be used that are easily performed and above all reversible without complications. Until a reliable prognosis of the paresis can be made, adhesive taping is suited for the temporary treatment of paralytic ectropion. Adhesive taping is simple and can be performed by the patient.

  9. Influences of irradiating on spectrum temporary to relaxations

    International Nuclear Information System (INIS)

    Mahmudov, A.Y.; Akhmedov, F.A.

    2002-01-01

    Full text: Generality of chain macromolecular system construction allows to identify a majority of features of polymers of like nature. So on considered in given work irradiated model no condition on descending in not put. Model consists of gaussian chains with (N x m) numbers (from them N - a number of chains and m - a number an beads on chains, which are distinguished one from another by the degree a mobility) potential interaction centres with the surround environment. The interaction carries of inter and intramolecular nature , including and hydrogen bond. Between these centres there are constant and casual contacts. For terminal volume and terminal time possible to neglect influences casual bonds of fluctuation.Let number of constant contacts is equally n. Changing of number of contacts under the action of irradiating carries a kinetic nature and so it is described by the differential equation, which parameters are formation frequencies and destroying the contacts. Decision of this equation allows to calculate a complex module of bounce, on which possible judge on velocities of relaxation process irradiated polymer. At the equality unit a relations of frequencies of formation and destroying of the contact occurs as it were a dynamic balance and spectrum temporary relaxations corresponds a spectrum non radiating models. An accumulation of energy occurs under small energy of irradiating in the in that nodes, which encircled smaller number nodes. So small doses of irradiating a polymer show a wing of spectrum temporary to relaxations in the lion. Comparison of obtained formula with available in literature by data has shown that frequency of forming the contacts much less, than their destruction frequency

  10. Protection of stapled colorectal anastomoses with a biodegradable device : the C-Seal feasibility study

    NARCIS (Netherlands)

    Kolkert, Joe L.; Havenga, Klaas; Hoedemaker, Henk O. ten Cate; Zuidema, Johan; Ploeg, Rutger J.

    BACKGROUND: A colorectal anastomotic leak can be life-threatening. We have assessed the feasibility of a new intraluminal biodegradable bypass device that we designed to avoid anastomotic leakage and the necessity of a temporary stoma. METHODS: Fifteen patients underwent colorectal surgery. Before

  11. TREHS (Temporary Rivers Ecological and Hydrological Status): new software for investigating the degree of hydrologic alteration of temporary streams.

    Science.gov (United States)

    Gallart, Francesc; Llorens, Pilar; Cid, Núria; latron, Jérôme; Bonada, Núria; Prat, Narcís

    2017-04-01

    The evaluation of the hydrological alteration of a stream due to human activities is a first step to assess its overall quality and to design management strategies for its potential restoration. This task is currently made comparing impacted against unimpacted hydrographs, with the help of software tools, such as the IHA (Indicators of Hydrologic Alteration). Then, the environmental evaluation of the hydrological alteration is to be made in terms of its expectable menace for the original biological communities and/or its help for the spread of invasive species. However, when the regime of the target stream is not perennial, there are four main difficulties for implementing methods for assessing hydrological alteration: i) the main hydrological features relevant for biological communities in a temporary stream are not quantitative (discharges) but qualitative (temporal patterns of states such as flowing water, stagnant pools or lack of surface water), ii) stream flow records do not inform on the temporal occurrence of stagnant pools, which act as refugees for many species during the cessation of flow, iii) as most of the temporary streams are ungauged, the evaluation of their regime must be determined by using alternative methods such as remote sensing or citizen science, and iv) the biological quality assessment of the ecological status of a temporary stream must be conducted following a sampling schedule adapted to the flow regime and using adequate reference conditions. In order to overcome these challenges using an operational approach, the TREHS freely available software tool has been developed within the EU LIFE TRIVERS project (LIFE13 ENV/ES/000341). This software allows for the input of information coming from flow simulations obtained using any rainfall-runoff model (to set an unimpacted reference stream regime) and compares them with the information obtained from flow gauging records, interviews made to local citizens, instantaneous observations made by

  12. The Temporal Organization Grid: A New Classification System of Temporary Organizations

    Directory of Open Access Journals (Sweden)

    Vallari Chandna

    2017-03-01

    Full Text Available With the increased recognition of the key role played by time in processes and outcomes, there has been a renewed focus on temporary organizations. Temporary organizational forms tend to receive attention due to certain characteristics that are unique to them, as compared to permanent organizations, with regard to issues like trust, communication, organizational structure, innovation and creativity among others. They have also been known to generate significant benefits for the organizations participating in them. But to study them in detail, a comprehensive classification system of temporary organizations is needed, which has so far been missing in the extant literature. This paper sets forth a classification grid for temporary organizations which is its primary purpose and also examines the different strategically important variables that further define the typological framework and that act as determinants of success of these temporary organizations.

  13. Hexagonal Boron Nitride Impregnated Silane Composite Coating for Corrosion Resistance of Magnesium Alloys for Temporary Bioimplant Applications

    Directory of Open Access Journals (Sweden)

    Saad Al-Saadi

    2017-11-01

    Full Text Available Magnesium and its alloys are attractive potential materials for construction of biodegradable temporary implant devices. However, their rapid degradation in human body fluid before the desired service life is reached necessitate the application of suitable coatings. To this end, WZ21 magnesium alloy surface was modified by hexagonal boron nitride (hBN-impregnated silane coating. The coating was chemically characterised by Raman spectroscopy. Potentiodynamic polarisation and electrochemical impedance spectroscopy (EIS of the coated alloy in Hanks’ solution showed a five-fold improvement in the corrosion resistance of the alloy due to the composite coating. Post-corrosion analyses corroborated the electrochemical data and provided a mechanistic insight of the improvement provided by the composite coating.

  14. Scalable devices

    KAUST Repository

    Krüger, Jens J.

    2014-01-01

    In computer science in general and in particular the field of high performance computing and supercomputing the term scalable plays an important role. It indicates that a piece of hardware, a concept, an algorithm, or an entire system scales with the size of the problem, i.e., it can not only be used in a very specific setting but it\\'s applicable for a wide range of problems. From small scenarios to possibly very large settings. In this spirit, there exist a number of fixed areas of research on scalability. There are works on scalable algorithms, scalable architectures but what are scalable devices? In the context of this chapter, we are interested in a whole range of display devices, ranging from small scale hardware such as tablet computers, pads, smart-phones etc. up to large tiled display walls. What interests us mostly is not so much the hardware setup but mostly the visualization algorithms behind these display systems that scale from your average smart phone up to the largest gigapixel display walls.

  15. Thermonuclear device

    International Nuclear Information System (INIS)

    Honda, Takuro; Maki, Koichi.

    1997-01-01

    The present invention provides a thermonuclear device, in which integrity of a measuring device is kept, the reactor wall temperature and wear of armour materials are monitored accurately even under intense radiation rays, so that the flow rate of coolants and plasma power can be controlled by using the signals. Infrared rays generated from the surface of the armour materials disposed on a first wall are detected to measure the reactor wall temperature. Coolant flow rate and plasma power are controlled based on the obtained reactor wall temperature. In addition, infrared rays generated from the back of the armour materials are detected to obtain the surface temperature in order to avoid intense radiation rays from plasmas. The coolant flow rate and the plasma power are controlled based on the obtained temperature on the surface of the reactor thereby controlling the temperature of the first wall and the armour material to 300degC or lower in a case of the first wall made of stainless steel and 1000degC or lower in a case of the armour material made of graphite. (I.S.)

  16. Thermonuclear device

    International Nuclear Information System (INIS)

    Kuriyama, Masaaki; Yamamoto, Masahiro; Furuyama, Masayuki; Saito, Ryusei.

    1981-01-01

    Purpose: To enable the efficient and rapid cooling of a vacuum vessel by cooling with gas when the temperature of the vacuum vessel is higher than the boiling point of water and cooling with water when the temperature is lower than the boiling point of water. Constitution: A cooling pipe is provided through an insulating pipe on the outer periphery of a vacuum vessel. The cooling pipe communicates through a cooling gas valve and a coolant valve with a cooling gas supply device and a coolant supply device, and a heat exchanger is disposed at the pipe. When the vessel is higher than the boiling point of the coolant the coolant valve is closed and the cooling gas valve is opened and gas is supplied to cool the vessel. The gas is recoverd through a heat exchanger. On the other hand, when the temperature of vessel is lower than the boiling point of the coolant, the gas valve is closed, the coolant valve is opened, and the vessel is cooled with coolant. The vacuum vessel can be cooled for short time employing both the gas and the coolant together. (Yoshino, Y.)

  17. Thermonuclear device

    International Nuclear Information System (INIS)

    Takano, Hirohisa; Nakamoto, Kazunari; Hanai, Satoshi.

    1984-01-01

    Purpose: To provide coils of high mechanical strength for use at the center of a torus type thermonuclear device. Constitution: A plurality of copper plates having cooling holes and bolt holes and insulation paper sheets of the same shape are prepared. The copper plate is different from the insulation paper sheet only in that the position-phase angle of the opening portion is larger by 15 - 30 0 . The copper plates and the insulation paper sheets are alternately stacked by a required number of turns while displacing the angle, and then clamped by bolts to form a mechanically strong coil with no metallurgical joining. Further, since the insulation paper sheets are not present in the radial direction and only one insulation paper sheet is inserted for each turn in the direction of the coil height, the space occupied by the coil can be decreased. According to this invention, the magnetic flux density at the center of the device can be increased as compared with the conventional case to thereby apply a higher voltage on the side of plasmas. (Moriyama, K.)

  18. Irradiation device

    International Nuclear Information System (INIS)

    Suzuki, Toshimitsu.

    1989-01-01

    In an irradiation device for irradiating radiation rays such as electron beams to pharmaceuticals, etc., since the distribution of scanned electron rays was not monitored, the electron beam intensity could be determined only indirectly and irradiation reliability was not satisfactory. In view of the above, a plurality of monitor wires emitting secondary electrons are disposed in the scanning direction near a beam take-out window of a scanning duct, signals from the monitor wires are inputted into a display device such as a cathode ray tube, as well as signals from the monitor wires at the central portion are inputted into counting rate meters to measure the radiation dose as well. Since secondary electrons are emitted when electron beams pass through the monitor wires and the intensity thereof is in proportion with the intensity of incident electron beams, the distribution of the radiation dose can be monitored by measuring the intensity of the emitted secondary electrons. Further, uneven irradiation, etc. can also be monitored to make the radiation of irradiation rays reliable. (N.H.)

  19. Using a new device to prevent pulmonary embolisms during pharmacomechanical thrombectomy.

    Science.gov (United States)

    Calleja, E; Ciampi, J J; Puche, J J; Lanciego, C

    2018-04-20

    We have used a new device to prevent pulmonary embolism during pharmacomechanical thrombectomy in a 25-year-old postpartum woman. The Angel® catheter (BiO2 Medical Inc., Golden, CO, USA) is a temporary device that combines the functions of a vena cava filter (VCF) with those of a triple-lumen central venous catheter. Normally, a VCF is implanted to prevent pulmonary embolism during pharmacomechanical thrombectomy. However, the complications associated with VCFs increase with time, not all of the filter can always be retrieved, and there can be iatrogenic effects both during implantation and retrieval. In our experience, this new device is much simpler to deploy and to retrieve. As is shown in this case, this temporary device can be an interesting alternative to a VCF for preventing pulmonary embolisms during pharmacomechanical thrombectomy. Copyright © 2018 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.

  20. Laser, light, and energy devices for cellulite and lipodystrophy.

    Science.gov (United States)

    Peterson, Jennifer D; Goldman, Mitchel P

    2011-07-01

    Cellulite affects all races, and it is estimated that 85% of women older than 20 years have some degree of cellulite. Many currently accepted cellulite therapies target deficiencies in lymphatic drainage and microvascular circulation. Devices using radiofrequency, laser, and light-based energies, alone or in combination and coupled frequently with tissue manipulation, are available for improving cellulite. Laser assisted liposuction may improve cellulite appearance. Although improvement using these devices is temporary, it may last several months. Patients who want smoother skin with less visible cellulite can undergo a series of treatments and then return for additional treatments as necessary. Copyright © 2011 Elsevier Inc. All rights reserved.

  1. Practical microwave electron devices

    CERN Document Server

    Meurant, Gerard

    2013-01-01

    Practical Microwave Electron Devices provides an understanding of microwave electron devices and their applications. All areas of microwave electron devices are covered. These include microwave solid-state devices, including popular microwave transistors and both passive and active diodes; quantum electron devices; thermionic devices (including relativistic thermionic devices); and ferrimagnetic electron devices. The design of each of these devices is discussed as well as their applications, including oscillation, amplification, switching, modulation, demodulation, and parametric interactions.

  2. Thermonuclear device

    International Nuclear Information System (INIS)

    Furuyama, Masayuki.

    1979-01-01

    Purpose: To provide the subject device wherein a conductive short-circuiting ring is installed in the vicinity of the bonded part of bellows and thick portion of vacuum vessel in the small circumferential direction of torus, thereby to reduce the electromagnetic force generated at the bellows. Constitution: A conductive short-circuiting ring is provided in the vicinity of the connected part of a thick portion and bellows portion. By this organization, a saddle type current generated at the thick portion by a vertical magnetic field flows through the short-circuiting ring because the resistance at a part where the short-circuiting ring is provided is reduced, and the current flowing through the bellows is remarkably reduced. For this reason, the electromagnetic force generated at the bellows is reduced thereby to prevent the bellows from being destroyed by the electromagnetic force. (Yoshihara, H.)

  3. Electrophoresis device

    Science.gov (United States)

    Rhodes, P. H.; Snyder, R. S. (Inventor)

    1982-01-01

    A device for separating cellular particles of a sample substance into fractionated streams of different cellular species includes a casing having a distribution chamber, a separation chamber, and a collection chamber. The electrode chambers are separated from the separation chamber interior by means of passages such that flow variations and membrane variations around the slotted portion of the electrode chamber do not enduce flow perturbations into the laminar buffer curtain flowing in the separation chamber. The cellular particles of the sample are separated under the influence of the electrical field and the separation chamber into streams of different cellular species. The streams of separated cells enter a partition array in the collection chamber where they are fractionated and collected.

  4. Thermonuclear device

    International Nuclear Information System (INIS)

    Suzuki, Shohei

    1988-01-01

    Purpose: To obtain high voltage withstanding current introduction terminals not suffering from the effects of the reduction in the creeping voltage withstanding property by the application of magnetic fields. Constitution: This invention concerns a current introduction terminal for supplying electric current to coils for use in a thermonuclear device, etc. The conductor of the current introduction terminal on the side of vacuum is completely covered with solid insulator. This can eliminate the portion of securing the creeping withstanding voltage. The voltage withstanding characteristics of the solid insulator covering the portion of the conductor on the side of vacuum has a constant value irrespective of the atmosphere or the absence or presence of magnetic fields. Accordingly, the voltage withstanding characteristics of the current introduction terminal on the side of vacuum are determined by the property of the solid insulator, which is not reduced by the application of magnetic fields. (Ikeda, J.)

  5. Safety device of thermonuclear device

    International Nuclear Information System (INIS)

    Aoki, Isao; Ueda, Shuzo; Seki, Yasushi; Sakurai, Akiko; Kasahara, Fumio; Obara, Atsushi; Yamauchi, Michinori.

    1997-01-01

    The present invention provides a safety device against an event of intrusion of coolants in a vacuum vessel. Namely, a coolant supply system comprises cooling tubes for supplying coolants to main reactor structure components including a vacuum vessel. A detection means detects leakage of coolants in the vacuum vessel. A coolant supply control means controls the supply of coolants to the main reactor structural components based on the leakage detection signals of the detection means. A stagnated material discharging means discharges stagnated materials in the main reactor structural components caused by the leakage of coolants. The leakage of coolants (for example, water) in the vacuum vessel can thus be detected by the water detection device in the vacuum vessel. A control value of a coolant supply means is closed by the leakage detection signals. The supply of coolants to the main reactor structural components is restricted to suppress the leakage. The stagnated materials are discharged to a tank by way of a water draining valve. (I.S.)

  6. 78 FR 33216 - Temporary Change of Dates for Recurring Marine Event in the Fifth Coast Guard District, Mattaponi...

    Science.gov (United States)

    2013-06-04

    ... 1625-AA08 Temporary Change of Dates for Recurring Marine Event in the Fifth Coast Guard District, Mattaponi Drag Boat Race, Mattaponi River; Wakema, VA AGENCY: Coast Guard, DHS. ACTION: Temporary final rule. SUMMARY: The Coast Guard is establishing a temporary change to the enforcement period of special local...

  7. 77 FR 12723 - Labor Certification Process for the Temporary Employment of Aliens in Agriculture in the United...

    Science.gov (United States)

    2012-03-02

    ... the Temporary Employment of Aliens in Agriculture in the United States; Announcement of Non- Material... reasons in great detail in the preamble of the ``Temporary Agricultural Employment of H-2A Aliens in the... set the AEWR. See ``Temporary Agricultural Employment of H-2A Aliens in the United States; Modernizing...

  8. 77 FR 28305 - Temporary Rule To Delay Start Date of 2012-2013 South Atlantic Black Sea Bass Commercial Fishing...

    Science.gov (United States)

    2012-05-14

    .... 120501426-2426-01] RIN 0648-BB98 Temporary Rule To Delay Start Date of 2012-2013 South Atlantic Black Sea... this temporary rule to delay the start date of the 2012-2013 fishing season for the commercial black... temporary rule delays the start date of the 2012-2013 commercial fishing season for black sea bass from June...

  9. Cystoscopic temporary ureteral catheterization during radical vaginal and abdominal trachelectomy.

    Science.gov (United States)

    Abu-Rustum, Nadeem R; Sonoda, Yukio; Black, Destin; Chi, Dennis S; Barakat, Richard R

    2006-11-01

    To describe the role of temporary retrograde ureteral catheterization at the time of fertility-sparing radical vaginal or abdominal trachelectomy in women with early-stage cervical cancer. We analyzed a prospectively maintained database of all patients with cervical cancer who were explored for radical vaginal or abdominal trachelectomy at our institution. Cystourethroscopy and ureteral catheterization were performed prior to the vaginal or abdominal operation in all patients, except two pediatric ones. Temporary bilateral retrograde ureteral catheters were planned for all patients as part of our routine procedure to facilitate identification of the distal ureters. 5Fr whistle-tip or open-ended catheters were used and usually advanced to approximately 20 cm. Catheters were removed at the end of the operation in all cases. All catheters were inserted by a gynecologic oncology fellow or attending. Between 11/01 and 12/05, 40 patients were taken to the operating room for planned fertility-sparing radical vaginal or abdominal trachelectomy. We previously reported on two pediatric patients; they are excluded from this report. The median age for adult patients was 32 years (mean, 31.6; range, 23-40). International Federation of Gynecology and Obstetrics (FIGO) stage included IB1 (26), IA2 (6), and IA1 with lymphovascular invasion (6). Thirty-four patients underwent radical vaginal trachelectomy and four underwent a radical abdominal trachelectomy. Two (5%) of 38 patients required immediate completion radical hysterectomy due to extensive endocervical disease (one in the vaginal group and one in the abdominal group). Bilateral ureteral catheters were inserted successfully in 37 (97%) of 38 patients and facilitated identification of the distal ureter during the dissection. In one case, the right ureteral orifice could not be successfully catheterized, and the case was completed with unilateral catheterization. The estimated time to perform this part of the operation was

  10. Efficacy of transpalatal arch as an anchorage reinforcing unit during orthodontic space closure: A three-dimensional finite element study

    Directory of Open Access Journals (Sweden)

    Vishal Shrishail Kudagi

    2017-01-01

    Full Text Available Background and Objectives: Connecting the contralateral upper molars by means of a transpalatal arch (TPA is thought to decrease the tendency of the molars to move mesially in response to orthodontic force (i.e., provide orthodontic anchorage. This study was hence conducted to investigate the effects of the TPA on the displacement of the molars and stresses generated in the periodontium during orthodontic tooth movement using the finite element method (FEM. Materials and Methods: A three-dimensional (3D model was generated using medical modeling software (Mimics using the computed tomography slice images of the skull which were obtained at a slice thickness of 1 mm. From this, the finite element model was built using HyperMesh and analysis was performed using PATRAN software (MSC Software Corporation, 4675 MacArthur Court, Newport Beach, California 92660. The 3D finite element models were fabricated in two versions such as maxillary first molars including their associated periodontal ligament and alveolar bone one with TPA and another without TPA. Both were subjected to orthodontic forces, and the resultant stress patterns and displacements between the models with and without TPA were determined. Results: The stress and displacement plots in this study failed to show any significant differences in stress and displacement within the periodontium of molars, between the two models – one with TPA and the other without, in response to the orthodontic force. Interpretation and Conclusion: The results of the current finite element analysis, therefore, suggest that the presence of a TPA brings about no change in the initial dental and periodontal stress distribution and displacement.

  11. A Component-Based Study of the Effect of Diameter on Bond and Anchorage Characteristics of Blind-Bolted Connections.

    Directory of Open Access Journals (Sweden)

    Muhammad Nasir Amin

    Full Text Available Structural hollow sections are gaining worldwide importance due to their structural and architectural advantages over open steel sections. The only obstacle to their use is their connection with other structural members. To overcome the obstacle of tightening the bolt from one side has given birth to the concept of blind bolts. Blind bolts, being the practical solution to the connection hindrance for the use of hollow and concrete filled hollow sections play a vital role. Flowdrill, the Huck High Strength Blind Bolt and the Lindapter Hollobolt are the well-known commercially available blind bolts. Although the development of blind bolts has largely resolved this issue, the use of structural hollow sections remains limited to shear resistance. Therefore, a new modified version of the blind bolt, known as the "Extended Hollo-Bolt" (EHB due to its enhanced capacity for bonding with concrete, can overcome the issue of low moment resistance capacity associated with blind-bolted connections. The load transfer mechanism of this recently developed blind bolt remains unclear, however. This study uses a parametric approach to characterising the EHB, using diameter as the variable parameter. Stiffness and load-carrying capacity were evaluated at two different bolt sizes. To investigate the load transfer mechanism, a component-based study of the bond and anchorage characteristics was performed by breaking down the EHB into its components. The results of the study provide insight into the load transfer mechanism of the blind bolt in question. The proposed component-based model was validated by a spring model, through which the stiffness of the EHB was compared to that of its components combined. The combined stiffness of the components was found to be roughly equivalent to that of the EHB as a whole, validating the use of this component-based approach.

  12. A Component-Based Study of the Effect of Diameter on Bond and Anchorage Characteristics of Blind-Bolted Connections.

    Science.gov (United States)

    Amin, Muhammad Nasir; Zaheer, Salman; Alazba, Abdulrahman Ali; Saleem, Muhammad Umair; Niazi, Muhammad Umar Khan; Khurram, Nauman; Amin, Muhammad Tahir

    2016-01-01

    Structural hollow sections are gaining worldwide importance due to their structural and architectural advantages over open steel sections. The only obstacle to their use is their connection with other structural members. To overcome the obstacle of tightening the bolt from one side has given birth to the concept of blind bolts. Blind bolts, being the practical solution to the connection hindrance for the use of hollow and concrete filled hollow sections play a vital role. Flowdrill, the Huck High Strength Blind Bolt and the Lindapter Hollobolt are the well-known commercially available blind bolts. Although the development of blind bolts has largely resolved this issue, the use of structural hollow sections remains limited to shear resistance. Therefore, a new modified version of the blind bolt, known as the "Extended Hollo-Bolt" (EHB) due to its enhanced capacity for bonding with concrete, can overcome the issue of low moment resistance capacity associated with blind-bolted connections. The load transfer mechanism of this recently developed blind bolt remains unclear, however. This study uses a parametric approach to characterising the EHB, using diameter as the variable parameter. Stiffness and load-carrying capacity were evaluated at two different bolt sizes. To investigate the load transfer mechanism, a component-based study of the bond and anchorage characteristics was performed by breaking down the EHB into its components. The results of the study provide insight into the load transfer mechanism of the blind bolt in question. The proposed component-based model was validated by a spring model, through which the stiffness of the EHB was compared to that of its components combined. The combined stiffness of the components was found to be roughly equivalent to that of the EHB as a whole, validating the use of this component-based approach.

  13. Laser-Modified Surface Enhances Osseointegration and Biomechanical Anchorage of Commercially Pure Titanium Implants for Bone-Anchored Hearing Systems

    Science.gov (United States)

    Omar, Omar; Simonsson, Hanna; Palmquist, Anders; Thomsen, Peter

    2016-01-01

    Osseointegrated implants inserted in the temporal bone are a vital component of bone-anchored hearing systems (BAHS). Despite low implant failure levels, early loading protocols and simplified procedures necessitate the application of implants which promote bone formation, bone bonding and biomechanical stability. Here, screw-shaped, commercially pure titanium implants were selectively laser ablated within the thread valley using an Nd:YAG laser to produce a microtopography with a superimposed nanotexture and a thickened surface oxide layer. State-of-the-art machined implants served as controls. After eight weeks’ implantation in rabbit tibiae, resonance frequency analysis (RFA) values increased from insertion to retrieval for both implant types, while removal torque (RTQ) measurements showed 153% higher biomechanical anchorage of the laser-modified implants. Comparably high bone area (BA) and bone-implant contact (BIC) were recorded for both implant types but with distinctly different failure patterns following biomechanical testing. Fracture lines appeared within the bone ~30–50 μm from the laser-modified surface, while separation occurred at the bone-implant interface for the machined surface. Strong correlations were found between RTQ and BIC and between RFA at retrieval and BA. In the endosteal threads, where all the bone had formed de novo, the extracellular matrix composition, the mineralised bone area and osteocyte densities were comparable for the two types of implant. Using resin cast etching, osteocyte canaliculi were observed directly approaching the laser-modified implant surface. Transmission electron microscopy showed canaliculi in close proximity to the laser-modified surface, in addition to a highly ordered arrangement of collagen fibrils aligned parallel to the implant surface contour. It is concluded that the physico-chemical surface properties of laser-modified surfaces (thicker oxide, micro- and nanoscale texture) promote bone bonding

  14. Early Closure of a Temporary Ileostomy in Patients With Rectal Cancer

    DEFF Research Database (Denmark)

    Danielsen, Anne K; Park, Jennifer; Jansen, Jens E

    2017-01-01

    OBJECTIVE: The objective was to study morbidity and mortality associated with early closure (8-13 days) of a temporary stoma compared with standard procedure (closure after > 12 weeks) after rectal resection for cancer. BACKGROUND: A temporary ileostomy may reduce the risk of pelvic sepsis after .......0001. CONCLUSIONS: It is safe to close a temporary ileostomy 8 to 13 days after rectal resection and anastomosis for rectal cancer in selected patients without clinical or radiological signs of anastomotic leakage.......OBJECTIVE: The objective was to study morbidity and mortality associated with early closure (8-13 days) of a temporary stoma compared with standard procedure (closure after > 12 weeks) after rectal resection for cancer. BACKGROUND: A temporary ileostomy may reduce the risk of pelvic sepsis after...... creation) of a temporary ileostomy was compared with late closure (>12 weeks) in a multicenter randomized controlled trial, EASY (www.clinicaltrials.gov, NCT01287637) including patients undergoing rectal resection for cancer. Patients with a temporary ileostomy without signs of postoperative complications...

  15. IAEA issues recommendations regarding temporary restart of Dutch reactor

    International Nuclear Information System (INIS)

    2009-01-01

    Full text: An IAEA-led international team of nuclear reactor safety experts completed a safety review mission on 18 February at the High Flux Reactor (HFR) at Petten, in the Netherlands. The mission was conducted at the request of the Government of the Netherlands to review a set of previous evaluations made by the Dutch regulatory authority regarding the reactor's safety. The IAEA mission made a series of recommendations to enhance the safety of the year-long temporary restart. The recommendations included: - Performance of the monitoring system for leaks should be rigorously checked during the interim year of operation; - Temporary operation of the HFR cannot be extended beyond 1 March 2010; and - In case of any detected leakage from the coolant pipes, the reactor should be shut down immediately and repaired before restarting. The international team was composed of one IAEA staff member and five external experts from Argentina, Canada, France, India and South Africa. The IAEA's main conclusions and recommendations were presented in The Hague to the Ministry of Housing, Spatial Planning and the Environment and several other ministries. The team also provided a summary of its findings to the Netherlands Regulatory Authority. The team's final report will be submitted within two weeks. The HFR at Petten is one of five research reactors in the world that produces radioactive medical isotopes, used an estimated 40 million times annually for cancer treatment and the diagnosis of heart attacks. Prolonged outages at any of these five reactors have a far-reaching impact on medical treatments and diagnoses for patients around the globe. Since August 2008, the HFR reactor has been in shut-down status due to corrosion of pipes in its primary cooling circuit. The Nuclear Research and Consultancy Group (NRG), the operating organization for Petten, proposed a one-year restart of the HFR reactor, which was approved by the Dutch regulatory body. The reactor then resumed operation

  16. Thermonuclear device

    International Nuclear Information System (INIS)

    Suzuki, Shohei.

    1980-01-01

    Purpose: To improve the plasma confining efficiency in a thermonuclear device having magnet coils using super-conducting wires by decreasing the uneven magnetic field resulted from current supply terminals and wirings. Constitution: Current introduction terminals of magnet coils using superconducting wires are short circuitted with a superconducting short circuit wire. Upon supplying current to the coils, the resistance of the coils is rendered superconductive and the resistance of the short circuit wire is rendered normally conductive heated by a heater and the switch is closed. In this case, most parts of the current are flown through the resistance of the coils and the switch is opened when the current arrives at a predetermined value to render the resistance of the short circuit wire superconductive. Then, the current transfers from the thyristor power source to the resistance of the short circuit wire, whereby the resistance of the coils and that of the short circuit wire from a permanent current loop. In this conditions, since current flows through the short circuit wire and the coils and not to the current introduction terminals, no uniform magnetic field is generated. (Kawakami, Y.)

  17. Reluctance device

    International Nuclear Information System (INIS)

    Claridge, A.N.; Smith, A.J.

    1983-01-01

    A reluctance device comprises two or more phases, each of which has a rotor mounted for rotation within a tubular member and an annular stator positioned externally of the tubular member. The rotor and the internal surface of the tubular member are each provided with aligned, axially spaced apart annular arrays of teeth, the teeth on the rotor confronting those on the tubular member in radially spaced apart relationship. The stator encloses a coil which, when electrically energised, creates a plurality of magnetic flux paths each of which extends radially between the rotor and stator via the confronting teeth and the tubular member, and axially along both the rotor and the portion of the stator located radially outwardly of the coil. The portion of the tubular member intermediate the teeth thereon is provided with a non-magnetic insert in order to resist the axial passage of magnetic flux therethrough. In one of the claims, the tubular member comprises a portion of a nuclear reactor which is adapted to contain a reactor control rod, the rotor constituting a portion of the drive mechanism for the control rod contained in operation within the tubular member. (author)

  18. Protection device for a thermonuclear device

    International Nuclear Information System (INIS)

    Kawashima, Shuichi.

    1986-01-01

    Purpose: To exactly detect the void coefficients of coolants even under high magnetic fields thereby detect the overheat of a thermonuclear device at an early stage. Constitution: The protecting device of this invention comprises a laser beam generation device, a laser beam detection device and an accident detection device. The laser generation device always generates laser beams, which are permeated through coolants and detected by the laser beam detection device, the optical amount of which is transmitted to the accident detection device. The accident detection device judges the excess or insufficiency of the detected optical amount with respect to the optical amount of the laser beams under the stationary state as a reference and issues an accident signal. Since only the optical cables that do not undergo the effect of the magnetic fields are exposed to high magnetic fields in the protection device of this invention, a high reliability can be maintained. (Kamimura, M.)

  19. Failure of communication and capture: The perils of temporary unipolar pacing system.

    Science.gov (United States)

    Sahinoglu, Efe; Wool, Thomas J; Wool, Kenneth J

    2015-06-01

    We present a case of a patient with pacemaker dependence secondary to complete heart block who developed loss of capture of her temporary pacemaker. Patient developed torsades de pointes then ventricular fibrillation, requiring CPR and external cardioversion. After patient was stabilized, it was noticed that loss of capture of pacemaker corresponded with nursing care, when the pulse generator was lifted off patient׳s chest wall, and that patient׳s temporary pacing system had been programmed to unipolar mode without knowledge of attending cardiologist. This case highlights the importance of communication ensuring all caregivers are aware of mode of the temporary pacing system.

  20. Failure of communication and capture: The perils of temporary unipolar pacing system

    Directory of Open Access Journals (Sweden)

    Efe Sahinoglu, BChE

    2015-06-01

    Full Text Available We present a case of a patient with pacemaker dependence secondary to complete heart block who developed loss of capture of her temporary pacemaker. Patient developed torsades de pointes then ventricular fibrillation, requiring CPR and external cardioversion. After patient was stabilized, it was noticed that loss of capture of pacemaker corresponded with nursing care, when the pulse generator was lifted off patient׳s chest wall, and that patient׳s temporary pacing system had been programmed to unipolar mode without knowledge of attending cardiologist. This case highlights the importance of communication ensuring all caregivers are aware of mode of the temporary pacing system.

  1. In-stream biogeochemical processes of a temporary river.

    Science.gov (United States)

    Tzoraki, Ourania; Nikolaidis, Nikolaos P; Amaxidis, Yorgos; Skoulikidis, Nikolaos Th

    2007-02-15

    A reach at the estuary of Krathis River in Greece was used to assess how in-stream processes alter its hydrologic and biogeochemical regime. Krathis River exhibited high annual flow variability and its transmission losses become significant, especially during the dry months. These transmission losses are enhanced in chemistry due to release of nutrients from river sediments. These fluxes are significant because they correspond to 11% of the dissolved inorganic nitrogen flux of the river. Release of nitrogen species was influenced by temperature, while release of phosphate was not because phosphate levels were below the equilibrium concentration. There is a significant amount of sediments with fine composition that create "hot spot" areas in the river reach. These sediments are mobilized during the first flush events in the fall carrying with them a significant load of nutrient and suspended matter to the coastal zone. The nutrient organic content of sediments was also significant and it was studied in terms of its mineralization capacity. The capacity for mineralization was influenced by soil moisture, exhibiting significant capacity even at moisture levels of 40%. Temporary rivers are sensitive ecosystems, vulnerable to climate changes. In-stream processes play a significant role in altering the hydrology and biogeochemistry of the water and its impacts to the coastal zone.

  2. Retrograde amnesia after electroconvulsive therapy: a temporary effect?

    Science.gov (United States)

    Meeter, Martijn; Murre, Jaap M J; Janssen, Steve M J; Birkenhager, Tom; van den Broek, W W

    2011-07-01

    Although electroconvulsive therapy (ECT) is generally considered effective against depression, it remains controversial because of its association with retrograde memory loss. Here, we assessed memory after ECT in circumstances most likely to yield strong retrograde amnesia. A cohort of patients undergoing ECT for major depression was tested before and after ECT, and again at 3-months follow-up. Included were 21 patients scheduled to undergo bilateral ECT for severe major depression and 135 controls matched for gender, age, education, and media consumption. Two memory tests were used: a verbal learning test to assess anterograde memory function, and a remote memory test that assessed memory for news during the course of one year. Before ECT the patients' scores were lower than those of controls. They were lower again after treatment, suggesting retrograde amnesia. At follow-up, however, memory for events before treatment had returned to the pre-ECT level. Memory for events in the months after treatment was as good as that of controls. The sample size in this study was not large. Moreover, memory impairment did not correlate with level of depression, which may be due to restriction of range. Our results are consistent with the possibility that ECT as currently practiced does not cause significant lasting retrograde amnesia, but that amnesia is mostly temporary and related to the period of impairment immediately following ECT. Copyright © 2011 Elsevier B.V. All rights reserved.

  3. Mobile integrated temporary utility system. Innovative technology summary report

    International Nuclear Information System (INIS)

    1998-12-01

    The Mobile Integrated Temporary Utility System (MITUS) integrates portable electrical power along with communications and emergency alarm and lighting capabilities to provide safe, centralized power to work areas that need to be de-energized for decommissioning work. MITUS consists of a portable unit substation; up to twenty portable kiosks that house the power receptacles, communications, and emergency alarm and lighting systems; and a central communications unit. This system makes sequential decommissioning efforts efficient and cost-effective by allowing the integrated system to remain intact while being moved to subsequent work sites. Use of the MITUS also eliminates the need to conduct zero-energy tests and implement associated lock-out/tag-out procedures at partially de-energized facilities. Since the MITUS is a designed system, it can be customized to accommodate unique facility conditions simply by varying kiosks and transformer configurations. The MITUS is an attractive alternate to the use of portable generators with stand-alone communications and emergency system. It is more cost-effective than upgrading or reconfiguring existing power distribution systems

  4. Temporary corneal stem cell dysfunction after radiation therapy

    International Nuclear Information System (INIS)

    Hiroshi, Fujishima; Kazuo, Tsubota

    1996-01-01

    Radiation therapy can cause corneal and conjuctival abnormalities that sometimes require surgical treatment. Corneal stem cell dysfunction is described, which recovered after the cessation of radiation. Methods - A 44-year-old man developed a corneal epithelial abnormality associated with conjuctival and corneal inflammation following radiation therapy for maxillary cancer. Examination of brush cytology samples showed goblet cells in the upper and lower parts of the cornea, which showed increased fluorescein permeability, and intraepithelial lymphocytes. Impression cytology showed goblet cells in the same part of the cornea. Specular microscopy revealed spindle type epithelial cells. Patient follow up included artificial tears and an antibiotic ophthalmic ointment. The corneal abnormalities resolved after 4 months with improved visual acuity without any surgical intervention, but the disappearance of the palisades of Vogt did not recover at 1 year after radiation. Radiation therapy in this patient caused temporary stem cell dysfunction which resulted in conjunctivalisation in a part of the cornea. Although limbal stem cell function did not fully recover, this rare case suggested that medical options should be considered before surgery. (Author)

  5. Temporary refugia for coral reefs in a warming world

    Science.gov (United States)

    van Hooidonk, R.; Maynard, J. A.; Planes, S.

    2013-05-01

    Climate-change impacts on coral reefs are expected to include temperature-induced spatially extensive bleaching events. Bleaching causes mortality when temperature stress persists but exposure to bleaching conditions is not expected to be spatially uniform at the regional or global scale. Here we show the first maps of global projections of bleaching conditions based on ensembles of IPCC AR5 (ref. ) models forced with the new Representative Concentration Pathways (RCPs). For the three RCPs with larger CO2 emissions (RCP 4.5, 6.0 and 8.5) the onset of annual bleaching conditions is associated with ~ 510ppm CO2 equivalent; the median year of all locations is 2040 for the fossil-fuel aggressive RCP 8.5. Spatial patterns in the onset of annual bleaching conditions are similar for each of the RCPs. For RCP 8.5, 26% of reef cells are projected to experience annual bleaching conditions more than 5 years later than the median. Some of these temporary refugia include the western Indian Ocean, Thailand, the southern Great Barrier Reef and central French Polynesia. A reduction in the growth of greenhouse-gas emissions corresponding to the difference between RCP 8.5 and 6.0 delays annual bleaching in ~ 23% of reef cells more than two decades, which might conceivably increase the potential for these reefs to cope with these changes.

  6. Temporary work for children of members of the personnel

    CERN Multimedia

    2007-01-01

    TO ALL MEMBERS OF THE PERSONNEL During the period 11 June to 14 September 2007 inclusive, a limited number of temporary jobs at CERN (normally unskilled work of a routine nature) will be made available to children of members of the personnel (i.e. anyone holding an employment or association contract with CERN). It should be noted that candidates must be aged between 18 and 24 inclusive on the first day of the contract, and that they must have insurance cover for both illness and accident. In view of the limited number of jobs available, no children who have previously worked at CERN under this scheme can be considered. The duration of all appointments will be 4 weeks, the allowance being CHF 1663.- for this period. Candidates should apply via the HR Department's electronic recruitment system (E-rt): https://ert.cern.ch/browse_www/wd_pds?p_web_page_id=5466 Completed application forms must be returned to this service by 13 April 2007 at the latest. The results of the selection will be available on 11 May 200...

  7. Temporary work for children of members of the personnel

    CERN Multimedia

    2007-01-01

    TO ALL MEMBERS OF THE PERSONNEL During the period 11 June to 14 September 2007 included, there will be a limited number of jobs for temporary work at CERN (normally unskilled work of routine nature) which will be made available to children of members of the personnel (i.e. anyone holding an employment or association contract with CERN). It should be noted that candidates must be aged between 18 and 24 inclusive on the first day of the contract, and that they must have insurance cover for both illness and accident. In view of the limited number of jobs available, no children who have previously worked at CERN under this scheme can be considered. The duration of all appointments will be 4 weeks, the allowance being CHF 1663.- for this period. Candidates should apply via HR department's electronic recruitment system (E-rt): https://ert.cern.ch/browse_www/wd_pds?p_web_page_id=5466 Completed application forms must be returned to this service by 13 April 2007 at the latest. The results of the selection will be...

  8. Temporary work for children of members of the personnel

    CERN Multimedia

    2007-01-01

    TO ALL MEMBERS OF THE PERSONNEL During the period 11 June to 14 September 2007 inclusive, a limited number of temporary jobs at CERN (normally unskilled work of a routine nature) will be made available to children of members of the personnel (i.e. anyone holding an employment or association contract with CERN). It should be noted that candidates must be aged between 18 and 24 inclusive on the first day of the contract, and that they must have insurance cover for both illness and accident. In view of the limited number of jobs available, no children who have previously worked at CERN under this scheme can be considered. The duration of all appointments will be 4 weeks, the allowance being CHF 1663.- for this period. Candidates should apply via the HR Department's electronic recruitment system (E-rt): https://ert.cern.ch/browse_www/wd_pds?p_web_page_id=5466 Completed application forms must be returned to this service by 13 April 2007 at the latest. The results of the selection will be available on 11 May 2...

  9. Temporary work for children of members of the personnel

    CERN Multimedia

    2006-01-01

    TO ALL MEMBERS OF THE PERSONNEL During the period 12 June to 15 September 2006 included, there will be a limited number of jobs for temporary work at CERN (normally unskilled work of routine nature) which will be made available to children of members of the personnel (i.e. anyone holding an employment or association contract with CERN). It should be noted that candidates must be aged between 18 and 24 inclusive on the first day of the contract, and that they must have insurance cover for both illness and accident. In view of the limited number of jobs available, no children who have previously worked at CERN under this scheme can be considered. The duration of all appointments will be 4 weeks, the allowance being CHF 1640.- for this period. Candidates should apply via HR department's electronic recruitment system (E-rt) : https://ert.cern.ch/browse_www/wd_pds?p_web_page_id=4691 Completed application forms must be returned to this service by 17 April 2006 at the latest. The results of the selection will be...

  10. Temporary work for children of members of the personnel

    CERN Multimedia

    2006-01-01

    TO ALL MEMBERS OF THE PERSONNEL During the period 12 June to 15 September 2006 included, there will be a limited number of jobs for temporary work at CERN (normally unskilled work of routine nature) which will be made available to children of members of the personnel (i.e. anyone holding an employment or association contract with CERN). It should be noted that candidates must be aged between 18 and 24 inclusive on the first day of the contract, and that they must have insurance cover for both illness and accident. In view of the limited number of jobs available, no children who have previously worked at CERN under this scheme can be considered. The duration of all appointments will be 4 weeks, the allowance being CHF 1640.- for this period. Candidates should apply via HR department's electronic recruitment system (E-rt) : https://ert.cern.ch/browse_www/wd_pds?p_web_page_id=4691 Completed application forms must be returned to this service by 17 April 2006 at the latest. The results of the selection will be a...

  11. Elevated p21-Activated Kinase 2 Activity Results in Anchorage-Independent Growth and Resistance to Anticancer Drug–Induced Cell Death

    Directory of Open Access Journals (Sweden)

    Jerry W. Marlin

    2009-03-01

    Full Text Available p21-Activated kinase 2 (PAK-2 seems to be a regulatory switch between cell survival and cell death signaling. We have shown previously that activation of full-length PAK-2 by Rac or Cdc42 stimulates cell survival, whereas caspase activation of PAK-2 to the proapoptotic PAK-2p34 fragment is involved in the cell death response. In this study, we present a role of elevated activity of full-length PAK-2 in anchorage-independent growth and resistance to anticancer drug–induced apoptosis of cancer cells. Hs578T human breast cancer cells that have low levels of PAK-2 activity were more sensitive to anticancer drug–induced apoptosis and showed higher levels of caspase activation of PAK-2 than MDA-MB435 and MCF-7 human breast cancer cells that have high levels of PAK-2 activity. To examine the role of elevated PAK-2 activity in breast cancer, we have introduced a conditionally active PAK-2 into Hs578T human breast cells. Conditional activation of PAK-2 causes loss of contact inhibition and anchorage-independent growth of Hs578T cells. Furthermore, conditional activation of PAK-2 suppresses activation of caspase 3, caspase activation of PAK-2, and apoptosis of Hs578T cells in response to the anticancer drug cisplatin. Our data suggest a novel mechanism by which full-length PAK-2 activity controls the apoptotic response by regulating levels of activated caspase 3 and thereby its own cleavage to the proapoptotic PAK-2p34 fragment. As a result, elevated PAK-2 activity interrupts the apoptotic response and thereby causes anchorage-independent survival and growth and resistance to anticancer drug–induced apoptosis.

  12. Experimental Studies on Geocells and Mat Systems for Stabilization of Unpaved Shoulders and Temporary Roads

    Science.gov (United States)

    Guo, Jun

    Geosynthetics have been used to improve the performance of geomaterials, especially when weak soil exists in roadway applications. In this study, two types of geosynthetic materials, geocell and a mat system, were studied for their applications for unpaved roads and shoulders. The study of geocell was focused on its application for unpaved shoulders. The ability of geocell to improve different geomaterials over intermediate strength subgrade and its possible effect on vegetation were investigated. The study of the mat system was focused on investigating the performance of the mat system over soft and intermediate subgrade with different strengths under cyclic loading to simulate temporary roadway conditions. In the study of geocell for the application for unpaved shoulders, six large scale plate loading tests were conducted on a single type of geocell on target 5% CBR subgrade to investigate the benefits of geocell reinforcement on different base course and topsoil combinations. Different base course and topsoil combinations were investigated including: 200-mm thick unreinforced aggregate, 200-mm thick soil-aggregate mixture (50% aggregate and 50% top soil) with and without geocell reinforcement, 200-mm thick geocell-reinforced topsoil, 50-mm thick aggregate over 150-mm soil-aggregate mixture (50% aggregate and 50% top soil), and 50-mm thick top soil over 150-mm thick geocell-reinforced soil-aggregate mixture (50% aggregate and 50% top soil). Earth pressure cells were install at the interface between subgrade and base course to monitor the load distribution. The cyclic plate loading tests showed that geocell effectively reduced the permanent deformation and the geocell-reinforced soil-aggregate mixture slightly outperformed the unreinforced aggregate at the same thickness. The plate loading tests also suggested the topsoil cover resulted in large permanent deformations. A one-year long outdoor field vegetation test was conducted on base courses with different

  13. [On the temporary surplus population in the elementary stage of socialism in China].

    Science.gov (United States)

    Wang, Y; Chen, L

    1988-07-01

    The causes and patterns of China's surplus population are analyzed for the period 1951-1980. The authors view the surplus population as a temporary phenomenon that is advantageous to social development.

  14. Physical Exposures, Work Tasks, and OSHA-10 Training Among Temporary and Payroll Construction Workers.

    Science.gov (United States)

    Caban-Martinez, Alberto J; Santiago, Katerina M; Stillman, Jordan; Moore, Kevin J; Sierra, Danielle A; Chalmers, Juanita; Baniak, Melissa; Jordan, Melissa M

    2018-04-01

    We characterize and compare the self-reported physical exposures, work tasks, and OSHA-10 training in a non-probabilistic sample of temporary and payroll construction workers. In June 2016, a total of 250 payroll and temporary general laborers employed at Florida construction sites completed a survey at the job site as part of the falls reported among minority employees (FRAME) study. Workers employed through temp agencies (57.1%) were significantly more likely to report moving or lifting materials more than 100 pounds than payroll workers (38.5%; P < 0.01). Temporary construction workers with 10-hour OSHA training (22.2%) spent significantly less time with intense hand use/awkward hand posture than temporary workers without 10-hour OSHA training (46.9%; P = 0.048). Temp construction workers with OSHA 10-hour training reported less hazardous physical postures than workers without the same training.

  15. Functional Outcomes After Temporary Bridging With Locking Plates in Lisfranc Injuries

    NARCIS (Netherlands)

    van Koperen, Paul J.; de Jong, Vincent M.; Luitse, Jan S. K.; Schepers, Tim

    2016-01-01

    The standard operative treatment of Lisfranc fracture dislocations currently consists of open reduction and transarticular fixation. Recently, bridge plating has been used more often. Using joint spanning, the reduced fracture dislocation is temporary stabilized to minimize articular damage. The

  16. Estimating temporary and permanent stock price innovations on Croatian capital market

    Directory of Open Access Journals (Sweden)

    Tihana Škrinjarić

    2014-03-01

    Full Text Available This paper evaluates the size and duration of temporary and permanent stock price innovations on Croatian capital market in the structural VAR (vector autoregression framework with Blanchard and Quah (1989 decomposition. The purpose is to identify the effects of temporary price innovations in order to determine to which extent future stock prices can be predicted. Temporary components present in stock prices are explained throughout the mean-reversion hypothesis. This means that stock prices deviate from the fundamental values, but they will revert to their mean. In that way, to some extent, it is possible to predict future price movements. The results show that for the observed period from January 2000 to September 2013, temporary innovations account for only 2.62% of price variability over a two-year horizon. This means that forecasting the future movements of stock prices on Zagreb Stock Exchange is a difficult task.

  17. Temporary workers in the nuclear power industry: implications for the waste management program

    International Nuclear Information System (INIS)

    Melville, M.H.

    1984-01-01

    The employment of large number of temporary workers has become a growing and permanent characteristic of the nuclear power industry. In order to stay within the limits governing individual exposure to radiation in the workplace, the occupational risk has been spread among a larger segment of the population. Temporary workers, who make up one-third of the industry's work force, bear a disproportionate share of half the total annual occupational radiation dose. At issue is whether temporary workers should be grouped with the public at large or with the nuclear industry's work force, whose maximum limits are at least 10 times higher. This issue is relevant at a time when the search for a way to manage the mounting radioactive wastes will increase both the permanent and temporary work force. 44 references, 4 figures, 4 tables

  18. Instruction manual for operating the Sensys System for temporary traffic counts

    Science.gov (United States)

    2010-01-01

    This instruction manual provides information and the procedures for using the Sensys System, which was initially designed to operate in a server controlled network, for temporary traffic counts. The instructions will allow the user to fully understan...

  19. Working together: critical care nurses experiences of temporary staffing within Swedish health care: A qualitative study.

    Science.gov (United States)

    Berg Jansson, Anna; Engström, Åsa

    2017-08-01

    The aim of this study is to describe critical care nurses (CCN's) experiences of working with or as temporary agency staff. This explorative qualitative study is based on interviews with five agency CCNs and five regular CCNs, a total of ten interviews, focusing on the interviewees' experiences of daily work and temporary agency staffing. The interviews were analysed manually and thematically following an inductive approach. Four themes that illustrate both similarities and differences between regular and temporary agency CCNs emerged: "working close to patients versus being responsible for everything", "teamwork versus independence", "both groups needed" and "opportunities and challenges". The study findings illustrate the complexity of the working situation for agency and regular staff in terms of the organisation and management of the temporary agency nurses and the opportunities and challenges faced by both groups. Copyright © 2016 Elsevier Ltd. All rights reserved.

  20. A blockchain-based Decentralized System for proper handling of temporary Employment contracts

    OpenAIRE

    Pinna, Andrea; Ibba, Simona

    2017-01-01

    Temporary work is an employment situation useful and suitable in all occasions in which business needs to adjust more easily and quickly to workload fluctuations or maintain staffing flexibility. Temporary workers play therefore an important role in many companies, but this kind of activity is subject to a special form of legal protections and many aspects and risks must be taken into account both employers and employees. In this work we propose a blockchain-based system that aims to ensure r...