WorldWideScience

Sample records for temperature ion source

  1. Modeling of Electron Temperature in H- Ion Source

    Science.gov (United States)

    Morishita, Takatoshi; Ogasawara, Masatada; Hatayama, Akiyoshi

    2000-05-01

    The equation of electron temperature is included in a two point numerical code for a high power hydrogen negative ion source. The calculated results of the electron temperature are in good agreement with Japan Atomic Energy Research Institute (JAERI)’s experimental results. The scaling law of electron temperature is estimated as a function of input power and gas pressure. Energy input by arc discharge, energy loss by ionization, dissociation and loss on the wall are considered in the electron energy equation. The leak width on the wall at the cusp magnet is also calculated numerically. Energy loss on the wall is dominant, and is larger than the ionization loss. In a similarly enlarged JAERI’s Kamaboko source, electron density increases and electron temperature decreases under a constant energy input per unit volume. In this situation, H- extraction current increases despite the decrease in H- density because of the enlargement of the H- extraction area.

  2. High temperature electron beam ion source for the production of single charge ions of most elements of the Periodic Table

    CERN Document Server

    Panteleev, V N; Barzakh, A E; Fedorov, D V; Ivanov, V S; Moroz, F V; Orlov, S Y; Seliverstov, D M; Stroe, L; Tecchio, L B; Volkov, Y M

    2003-01-01

    A new type of a high temperature electron beam ion source (HTEBIS) with a working temperature up to 2500 deg. C was developed for production of single charge ions of practically all elements. Off-line tests and on-line experiments making use of the developed ion source coupled with uranium carbide targets of different density, have been carried out. The ionization efficiency measured for stable atoms of many elements varied in the interval of 1-6%. Using the HTEBIS, the yields and on-line production efficiency of neutron rich isotopes of Mn, Fe, Co, Cu, Rh, Pd, Ag, Cd, In, Sn and isotopes of heavy elements Pb, Bi, Po and some others have been determined. The revealed confinement effect of the ions produced in the narrow electron beam inside a hot ion source cavity has been discussed.

  3. Radioactive Ion Sources

    OpenAIRE

    Stora, T

    2014-01-01

    This chapter provides an overview of the basic requirements for ion sources designed and operated in radioactive ion beam facilities. The facilities where these sources are operated exploit the isotope separation online (ISOL) technique, in which a target is combined with an ion source to maximize the secondary beam intensity and chemical element selectivity. Three main classes of sources are operated, namely surface-type ion sources, arc discharge-type ion sources, and finally radio-frequenc...

  4. Potential profile near singularity point in kinetic Tonks-Langmuir discharges as a function of the ion sources temperature

    Science.gov (United States)

    Kos, L.; Tskhakaya, D. D.; Jelić, N.

    2011-05-01

    A plasma-sheath transition analysis requires a reliable mathematical expression for the plasma potential profile Φ(x) near the sheath edge xs in the limit ɛ ≡λD/ℓ =0 (where λD is the Debye length and ℓ is a proper characteristic length of the discharge). Such expressions have been explicitly calculated for the fluid model and the singular (cold ion source) kinetic model, where exact analytic solutions for plasma equation (ɛ =0) are known, but not for the regular (warm ion source) kinetic model, where no analytic solution of the plasma equation has ever been obtained. For the latter case, Riemann [J. Phys. D: Appl. Phys. 24, 493 (1991)] only predicted a general formula assuming relatively high ion-source temperatures, i.e., much higher than the plasma-sheath potential drop. Riemann's formula, however, according to him, never was confirmed in explicit solutions of particular models (e.g., that of Bissell and Johnson [Phys. Fluids 30, 779 (1987)] and Scheuer and Emmert [Phys. Fluids 31, 3645 (1988)]) since "the accuracy of the classical solutions is not sufficient to analyze the sheath vicinity" [Riemann, in Proceedings of the 62nd Annual Gaseous Electronic Conference, APS Meeting Abstracts, Vol. 54 (APS, 2009)]. Therefore, for many years, there has been a need for explicit calculation that might confirm the Riemann's general formula regarding the potential profile at the sheath edge in the cases of regular very warm ion sources. Fortunately, now we are able to achieve a very high accuracy of results [see, e.g., Kos et al., Phys. Plasmas 16, 093503 (2009)]. We perform this task by using both the analytic and the numerical method with explicit Maxwellian and "water-bag" ion source velocity distributions. We find the potential profile near the plasma-sheath edge in the whole range of ion source temperatures of general interest to plasma physics, from zero to "practical infinity." While within limits of "very low" and "relatively high" ion source temperatures

  5. Radioactive Ion Sources

    CERN Document Server

    Stora, T

    2013-01-01

    This chapter provides an overview of the basic requirements for ion sources designed and operated in radioactive ion beam facilities. The facilities where these sources are operated exploit the isotope separation online (ISOL) technique, in which a target is combined with an ion source to maximize the secondary beam intensity and chemical element selectivity. Three main classes of sources are operated, namely surface-type ion sources, arc discharge-type ion sources, and finally radio-frequency-heated plasma-type ion sources.

  6. Vacuum Arc Ion Sources

    CERN Document Server

    Brown, I.

    2013-12-16

    The vacuum arc ion source has evolved into a more or less standard laboratory tool for the production of high-current beams of metal ions, and is now used in a number of different embodiments at many laboratories around the world. Applications include primarily ion implantation for material surface modification research, and good performance has been obtained for the injection of high-current beams of heavy-metal ions, in particular uranium, into particle accelerators. As the use of the source has grown, so also have the operational characteristics been improved in a variety of different ways. Here we review the principles, design, and performance of vacuum arc ion sources.

  7. Classification of Ion Sources

    OpenAIRE

    Scrivens, R.

    2014-01-01

    In this chapter, the anatomy of an ion source is briefly described, as well as a few features of particle motion in electric and magnetic fields, and of particle dynamics and plasmas. Using this information, different types of ion sources are described, highlighting their main mode of operation.

  8. Performance of cryocoolers in a High Temperature Superconducting ECR ion source (HTS-ECR) and its application for the High Current Injector Programme at IUAC, New Delhi

    Science.gov (United States)

    Rodrigues, G.; Mathur, Y.; Rao, U. K.; Lakshmy, P. S.; Mandal, A.; Roy, A.; Kanjilal, D.

    2017-02-01

    At the Inter University Accelerator Centre, a high current injector programme (HCI) is being developed as an alternate injector to the superconducting linear accelerator (SC-LINAC). For this purpose, a high temperature superconducting ECR ion source, PKDELIS, based on Gifford McMahon cryocoolers was designed, installed and commissioned in the Low Energy Beam Transport section of the high current injector. The ion source will inject multiply charged ions having A/q ∼ 6 for further acceleration into the downstream RFQ and DTL accelerators before final injection into the superconducting linear accelerator. The details of the design, and experimental results of the ion source together with performance of the cryocoolers are presented in this paper.

  9. Novel laser ion sources

    CERN Document Server

    Fournier, P; Kugler, H; Lisi, N; Scrivens, R; Rodríguez, F V; Düsterer, S; Sauerbrey, R; Schillinger, H; Theobald, W; Veisz, L; Tisch, J W G; Smith, R A

    2000-01-01

    Development in the field of high-power laser systems with repetition rates of several Hz and energies of few joules is highly active and opening, giving new possibilities for the design of laser ions sources. Preliminary investigations on the use of four different laser and target configurations are presented: (1) A small CO/sub 2/ laser (100 mJ, 10.6 mu m) focused onto a polyethylene target to produce C ions at 1 Hz repetition rate (CERN). (2) An excimer XeCl laser (6 J, 308 nm) focused onto solid targets (Frascati). (3) A femtosecond Ti: sapphire laser (250 mJ, 800 nm) directed onto a solid targets (Jena). (4) A picosecond Nd: yttrium-aluminum-garnet (0.3 J, 532 nm) focused into a dense medium of atomic clusters and onto solid targets (London). The preliminary experimental results and the most promising schemes will be discussed with respect to the scaling of the production of high numbers of highly charged ions. Different lasers are compared in terms of current density at 1 m distance for each charge state...

  10. Enhanced life ion source for germanium and carbon ion implantation

    Energy Technology Data Exchange (ETDEWEB)

    Hsieh, Tseh-Jen; Colvin, Neil; Kondratenko, Serguei [Axcelis Technologies, Inc. 108 Cherry Hill Drive, Beverly, MA 01915 (United States)

    2012-11-06

    Germanium and carbon ions represent a significant portion of total ion implantation steps in the process flow. Very often ion source materials that used to produce ions are chemically aggressive, especially at higher temperatures, and result in fast ion source performance degradation and a very limited lifetime [B.S. Freer, et. al., 2002 14th Intl. Conf. on Ion Implantation Technology Proc, IEEE Conf. Proc., p. 420 (2003)]. GeF{sub 4} and CO{sub 2} are commonly used to generate germanium and carbon beams. In the case of GeF{sub 4} controlling the tungsten deposition due to the de-composition of WF{sub 6} (halogen cycle) is critical to ion source life. With CO{sub 2}, the materials oxidation and carbon deposition must be controlled as both will affect cathode thermionic emission and anti-cathode (repeller) efficiencies due to the formation of volatile metal oxides. The improved ion source design Extended Life Source 3 (Eterna ELS3) together with its proprietary co-gas material implementation has demonstrated >300 hours of stable continuous operation when using carbon and germanium ion beams. Optimizing cogas chemistries retard the cathode erosion rate for germanium and carbon minimizes the adverse effects of oxygen when reducing gas is introduced for carbon. The proprietary combination of hardware and co-gas has improved source stability and the results of the hardware and co-gas development are discussed.

  11. The prototype of radioactive ion source

    CERN Document Server

    Aleksandrov, A V; Kot, N K; Andrighetto, A; Stroe, L

    2001-01-01

    The design and experimental results of the RIB source prototype are presented.A source will have the container of sup 2 sup 3 sup 5 U compounds heated up to 2200-2500 degree C. Vapors of uranium fission obtained when the ion source is irradiated by the high-energy neutron flux, are then ionized and extracted from the source. In the experiments with the prototype loaded by sup 1 sup 2 C the source working temperature 2700 degree C was reached, the carbon ion current 10 nA was obtained. The total operation time of more than 100 hours with no performance degradation was demonstrated.

  12. Influence of temperature on properties of nitrogen plasma source ion implantation (N-PSII) of Ti6A14V alloy

    CERN Document Server

    Geng Man; Zhao Qing

    2001-01-01

    Specimens of Ti6Al4V alloy were implanted with nitrogen plasma source ion implantation (N-PSII) at temperatures between 100 degree C and 600 degree C to a ion dose of 4 x 10 sup 1 sup 7 cm sup - sup 2. Auger Electron Spectroscopy (AES) was used to determine the nitrogen concentration depth profiles. Microhardness measurements and pin-on-disk wear test were performed to evaluate the improvements of the surface modification. Glancing angle X-ray diffraction (XRD) was employed to determine the phases presented in the surface modified layer. The thickness of implanted layer increased by about an order of magnitude when the temperature was elevated from 100 degree C to 600 degree C. Higher surface hardness and wear resistance was also obtained at higher temperature. Scanning electron microscopy (SEM) showed distinct microstructural changes and the presence of titanium nitrides in the implanted surface

  13. Ion Sources for MedAustron

    CERN Document Server

    Lettry, J; Wallner, J; Sargsyan, E; CERN. Geneva. BE Department

    2010-01-01

    The MedAustron Ion therapy center will be constructed in Wiener Neustadt (Austria) in the vicinity of Vienna. Its accelerator complex consists of four ion sources, a linear accelerator, a synchrotron and a beam delivery system to the three medical treatment rooms and to the research irradiation room. The ion sources shall deliver beams of H31+, C4+ and light ions with utmost reliability and stability. This paper describes the features of the ion sources presently planned for the MedAustron facility; such as ion source main parameters, gas injection, temperature control and cooling systems. A dedicated beam diagnostics technique is proposed in order to characterize ECR ions beams; in the first drift region after the ion source, a fraction of the mixed beam is selected via moveable aperture. With standard beam diagnostics, we then aim to produce position-dependant observables such as ion-current density, beam energy distribution and emittance for each charge states to be compared to simulations of ECR e-heating...

  14. Resonance Ionization Laser Ion Sources

    CERN Document Server

    Marsh, B

    2013-01-01

    The application of the technique of laser resonance ionization to the production of singly charged ions at radioactive ion beam facilities is discussed. The ability to combine high efficiency and element selectivity makes a resonance ionization laser ion source (RILIS) an important component of many radioactive ion beam facilities. At CERN, for example, the RILIS is the most commonly used ion source of the ISOLDE facility, with a yearly operating time of up to 3000 hours. For some isotopes the RILIS can also be used as a fast and sensitive laser spectroscopy tool, provided that the spectral resolution is sufficiently high to reveal the influence of nuclear structure on the atomic spectra. This enables the study of nuclear properties of isotopes with production rates even lower than one ion per second and, in some cases, enables isomer selective ionization. The solutions available for the implementation of resonance laser ionization at radioactive ion beam facilities are summarized. Aspects such as the laser r...

  15. Polyatomic ions from a high current ion implanter driven by a liquid metal ion source.

    Science.gov (United States)

    Pilz, W; Laufer, P; Tajmar, M; Böttger, R; Bischoff, L

    2017-12-01

    High current liquid metal ion sources are well known and found their first application as field emission electric propulsion thrusters in space technology. The aim of this work is the adaption of such kind of sources in broad ion beam technology. Surface patterning based on self-organized nano-structures on, e.g., semiconductor materials formed by heavy mono- or polyatomic ion irradiation from liquid metal (alloy) ion sources (LMAISs) is a very promising technique. LMAISs are nearly the only type of sources delivering polyatomic ions from about half of the periodic table elements. To overcome the lack of only very small treated areas by applying a focused ion beam equipped with such sources, the technology taken from space propulsion systems was transferred into a large single-end ion implanter. The main component is an ion beam injector based on high current LMAISs combined with suited ion optics allocating ion currents in the μA range in a nearly parallel beam of a few mm in diameter. Different types of LMAIS (needle, porous emitter, and capillary) are presented and characterized. The ion beam injector design is specified as well as the implementation of this module into a 200 kV high current ion implanter operating at the HZDR Ion Beam Center. Finally, the obtained results of large area surface modification of Ge using polyatomic Bi 2 + ions at room temperature from a GaBi capillary LMAIS will be presented and discussed.

  16. Industrial ion sources broadbeam gridless ion source technology

    CERN Document Server

    Zhurin, Viacheslav V

    2012-01-01

    Due to the large number of uses of ion sources in academia and industry, those who utilize these sources need up to date and coherent information to keep themselves abreast of developments and options, and to chose ideal solutions for quality and cost-effectiveness. This book, written by an author with a strong industrial background and excellent standing, is the comprehensive guide users and developers of ion sources have been waiting for. Providing a thorough refresher on the physics involved, this resource systematically covers the source types, components, and the operational parameters.

  17. Optically pumped polarized ion sources

    Energy Technology Data Exchange (ETDEWEB)

    Zelenski, A.N.

    1995-12-31

    Polarization transfer collisions between protons, atomic hydrogen, or deuterium and optically pumped alkali-metal vapour are implemented in the high current optically pumped polarized ion source (OPPIS) and the laser driven source (LDS) of nuclear polarized atoms for target applications. The OPPIS technique overcomes the limitations on intensity of the conventional atomic beam source technique and meets the requirements of the new generation of polarization experiments at multi-GeV accelerators and colliders. 17 refs., 3 figs.

  18. STATUS OF ITEP DECABORANE ION SOURCE PROGRAM.

    Energy Technology Data Exchange (ETDEWEB)

    KULEVOY,T.V.; PETRENKO, S.V.; KUIBEDA, R.P.; SELEZNEV, D.N.; KOZLOV, A.V.; STASEVICH, YU.B.; SITNIKOV, A.L.; SHAMAILOV, I.M.; PERSHIN, V.I.; HERSHCOVITCH, A.; JOHNSON, B.M.; GUSHENETS, V.I.; OKS, E.M.; POOLE, H.J.; MASUNOV, E.S.; POLOZOV, S.M.

    2007-08-26

    The joint research and development program is continued to develop steady-state ion source of decaborane beam for ion implantation industry. Both Freeman and Bemas ion sources for decaborane ion beam generation were investigated. Decaborane negative ion beam as well as positive ion beam were generated and delivered to the output of mass separator. Experimental results obtained in ITEP are presented.

  19. Lithium alumino-silicate ion source development

    Science.gov (United States)

    Roy, Prabir Kumar; Seidl, Peter A.; Kwan, Joe W.; Greenway, Wayne G.; Waldron, William L.; Wu, James K.; Mazaheri, Kavous

    2009-11-01

    We report experimental progress on Li+ source development in preparation for warm dense matter heating experiments. To uniformly heat targets to electron-volt temperatures for the study of warm dense matter, we are pursuing the use of a low (E spodumene and β-eucryptite, each of area 0.31 cm2, have been fabricated for ion emission measurements. These surface ionization sources are heated to 1200 to 1300 C where they preferentially emit singly ionized alkali ions. Tight process controls were necessary in preparing and sintering the alumino-silicate to the porous tungsten substrate to produce an emitter that gives uniform ion emission, sufficient current density and low beam emittance. Current density limit of the two kinds have been measured, and ion species identification of possible contaminants has been verified with a Wien (E x B) filter.

  20. Characterization of ISOLDE ion source and ion source chemistry

    CERN Document Server

    Barbeau, Marion

    2014-01-01

    This report presents results of measurements made with the ISOLDE OFF-LINE mass separator [1]. The first part shows measurements of the ionization characteristics of noble gases in a VADIS ion source. The goal of the measurements was to determine the dependency of the extractable current of first and second noble gases ions with the electron energy. In the second part, investigation on in-target chemistry are presented. Here, the effect of injected sulfur hexafluoride ($SF_6$) on the release of oxygen from aluminium oxide ($Al_2 O_3$) was studied.

  1. Numerical Simulation of Multicomponent Ion Beam from Ion Sources

    CERN Document Server

    Alexandrov, V S; Kazarinov, Yu M; Shevtsov, V P; Shirkov, G D

    1999-01-01

    A program library for numerical simulation of a multicomponent charged particle beam from ion sources is presented. The library is aimed for simulation of high current, low energy multicomponent ion beam from ion source through beamline and realized under the Windows user interface for the IBM PC. It is used for simulation and optimization of beam dynamics and based on successive and consistent application of two methods: the momentum method of distribution function (RMS technique) and particle in cell method. The library has been used to simulate and optimize the transportation of tantalum ion beam from the laser ion source (CERN) and calcium ion beam from the ECR ion source (JINR, Dubna).

  2. Ion optics of RHIC electron beam ion source.

    Science.gov (United States)

    Pikin, A; Alessi, J; Beebe, E; Kponou, A; Okamura, M; Raparia, D; Ritter, J; Tan, Y; Kuznetsov, G

    2012-02-01

    RHIC electron beam ion source has been commissioned to operate as a versatile ion source on RHIC injection facility supplying ion species from He to Au for Booster. Except for light gaseous elements RHIC EBIS employs ion injection from several external primary ion sources. With electrostatic optics fast switching from one ion species to another can be done on a pulse to pulse mode. The design of an ion optical structure and the results of simulations for different ion species are presented. In the choice of optical elements special attention was paid to spherical aberrations for high-current space charge dominated ion beams. The combination of a gridded lens and a magnet lens in LEBT provides flexibility of optical control for a wide range of ion species to satisfy acceptance parameters of RFQ. The results of ion transmission measurements are presented.

  3. Laser ion source for isobaric heavy ion collider experiment.

    Science.gov (United States)

    Kanesue, T; Kumaki, M; Ikeda, S; Okamura, M

    2016-02-01

    Heavy-ion collider experiment in isobaric system is under investigation at Relativistic Heavy Ion Collider. For this experiment, ion source is required to maximize the abundance of the intended isotope. The candidate of the experiment is (96)Ru + (96)Zr. Since the natural abundance of particular isotope is low and composition of isotope from ion source depends on the composites of the target, an isotope enriched material may be needed as a target. We studied the performance of the laser ion source required for the experiment for Zr ions.

  4. Innovative launching schemes in ECR ion sources

    Directory of Open Access Journals (Sweden)

    Torrisi Giuseppe

    2017-01-01

    Full Text Available An optimised RF power delivery in magnetoplasmas of ECR ion sources is crucial in order to provide a cost effective upgrade (plasma density and temperature increase and multiply charged ions production of these machines without recurring to higher and higher magnetic fields, power level and pumping wave frequency. This can be done by following two strategies: a in a pure ECR-heating scenario, by multiplexing different frequencies; b in a modal-conversion scenario, by multiple-launching at different frequencies, controllable angles and polarization. The paper will show two typical cases in both the aforementioned scenarios, as developed at INFN-LNS. Test-benches have been developed on purpose, such as the “Plasma Reactor” and “Flexible Plasma Trap”, and solutions have been proposed also for ion beams current boosting in the injectors of the Superconducting Cyclotron.

  5. Innovative launching schemes in ECR ion sources

    Science.gov (United States)

    Torrisi, Giuseppe; Mascali, David; Sorbello, Gino; Castro, Giuseppe; Naselli, Eugenia; Leonardi, Ornella; Celona, Luigi; Gammino, Santo

    2017-10-01

    An optimised RF power delivery in magnetoplasmas of ECR ion sources is crucial in order to provide a cost effective upgrade (plasma density and temperature increase and multiply charged ions production) of these machines without recurring to higher and higher magnetic fields, power level and pumping wave frequency. This can be done by following two strategies: a) in a pure ECR-heating scenario, by multiplexing different frequencies; b) in a modal-conversion scenario, by multiple-launching at different frequencies, controllable angles and polarization. The paper will show two typical cases in both the aforementioned scenarios, as developed at INFN-LNS. Test-benches have been developed on purpose, such as the "Plasma Reactor" and "Flexible Plasma Trap", and solutions have been proposed also for ion beams current boosting in the injectors of the Superconducting Cyclotron.

  6. Ion transport from plasma ion source at ISOLTRAP

    CERN Document Server

    Steinsberger, Timo Pascal

    2017-01-01

    In this report, my work as CERN Summer Student at the ISOLTRAP experiment at ISOLDE is described. A new plasma ion source used as oine source for calibration and implemented before my arrival was commissioned and transportation settings for the produced ions to the ion traps were found. The cyclotron frequencies of 40Ar and the xenon isotopes 129-132Xe were measured using time-of-flight and phase-imaging ion-cyclotron-resonance mass spectroscopy.

  7. Development and testing of a lithium ion source and injector

    Directory of Open Access Journals (Sweden)

    P. A. Seidl

    2012-04-01

    Full Text Available We report on the development and testing of an intense lithium ion source and injector for an ion induction accelerator designed for warm, dense matter target heating experiments. The source is a 10.9-cm diameter aluminosilicate emitter on a porous tungsten substrate. For an injector voltage pulse of 120 kV, pulse duration of 1.0-μs FWHM, and an operating temperature of 1250°C, the source emits 35 mA of Li^{+} ions. The results follow experimental studies with much smaller sources. The key challenges included beam quality, source lifetime, and heat management.

  8. High Current Ion Sources and Injectors for Heavy Ion Fusion

    Energy Technology Data Exchange (ETDEWEB)

    Kwan, Joe W.

    2005-02-15

    Heavy ion beam driven inertial fusion requires short ion beam pulses with high current and high brightness. Depending on the beam current and the number of beams in the driver system, the injector can use a large diameter surface ionization source or merge an array of small beamlets from a plasma source. In this paper, we review the scaling laws that govern the injector design and the various ion source options including the contact ionizer, the aluminosilicate source, the multicusp plasma source, and the MEVVA source.

  9. A Plasma Ion Source for ISOLTRAP

    CERN Document Server

    Skov, Thomas Guldager

    2016-01-01

    In this report, my work testing the new Penning ion source as a summer student at ISOLTRAP is described. The project was composed of three stages: (1) Setting up a test laboratory in building 275, (2) characterizing the ion source, and (3) implementing and testing the source in the ISOLTRAP setup. After setting up the test laboratory, the ion source was tested in a constant pressure environment with produced ion currents in the range of nA . An extensive scan of the source ion current versus operating parameters (pressure, voltage) was performed. A setup with pulsed gas flow was also tested, allowing a reduction of the gas load on the vacuum system. The behavior of the ion source together with the ISOLTRAP setup was also investigated, allowing to understand current limitations and future directions of improvement.

  10. ECR ion source based low energy ion beam facility

    Indian Academy of Sciences (India)

    A nanogan type of ECR source based on a fully permanent magnet design was chosen for this purpose [3]. The ECR ion source along with all its peripheral electron- ics and vacuum components placed on a 200 kV high voltage platform provides multiply charged positive ions in a widely varying energy range from a few ...

  11. Cobalt alloy ion sources for focused ion beam implantation

    Energy Technology Data Exchange (ETDEWEB)

    Muehle, R.; Doebeli, M. [Paul Scherrer Inst. (PSI), Villigen (Switzerland); Zimmermann, P. [Eidgenoessische Technische Hochschule, Zurich (Switzerland)

    1997-09-01

    Cobalt alloy ion sources have been developed for silicide formation by focused ion beam implantation. Four eutectic alloys AuCo, CoGe, CoY and AuCoGe were produced by electron beam welding. The AuCo liquid alloy ion source was investigated in detail. We have measured the emission current stability, the current-voltage characteristics, and the mass spectrum as a function of the mission current. (author) 1 fig., 2 refs.

  12. 11. international conference on ion sources

    Energy Technology Data Exchange (ETDEWEB)

    Leitner, D.; Lyneis, C.; Cheng, D.; Galloway, M.L.; Leitner, M.; Todd, D.S.; Ciavola, G.; Gammino, S.; Celona, L.; Ando, L.; Torrisi, L.; Cavenago, M.; Galata, A.; Spaedtke, P.; Tinschert, K.; Lang, R.; Iannucci, R.; Leroy, R.; Barue, C.; Hitz, D.; Koivisto, H.; Suominen, P.; Tarvainen, O.; Beijers, H.; Brandenburg, S.; Vanrooyen, D.; Hillo, C.; Kuchler, D.; Homeyer, H.; Rohrich, J.; Schachter, L.; Dobrescu, S.; Nakagawa, T.; Higurashi, Y.; Kidera, M.; Aihara, T.; Kase, M.; Goto, A.; Yang, Y.; Zhao, H.W.; Zhang, Z.M.; Zhang, X.Z.; Guo, X.H.; He, W.E.; Sun, L.T.; Yuan, P.; Song, M.T.; Xie, Z.Q.; Cao, Y.; Zhan, W.L.; Wei, B.W.; Bricault, P.; Lau, C.; Essabaa, S.; Cheikh Mhamed, M.; Bajeat, O.; Ducourtieux, M.; Lefort, H.; Panteleev, V.N.; Barzakh, A.E.; Fedorov, D.V.; Ionan, A.M.; Mezilev, K.A.; Moroz, F.V.; Orlov, S.Y.; Volkov, Y.M.; Andrighetto, A.; Lhersonneau, G.; Rizzi, V.; Tecchio, L.B.; Dubois, M.; Gaubert, G.; Jardins, P.; Lecesne, N.; Leroy, R.; Pacquet, J.Y.; Saint Laurent, M.G.; Villari, A.C.O.; Bajeat, O.; Essabaa, S.; Lau, C.; Menna, M.; Franberg, H.; Ammann, M.; Gdggeler, H.W.; Koster, U.; Allen, F.; Biedermann, C.; Radtke, R.; Ames, F.; Baartman, R.; Bricault, P.; Jayamanna, K.; Lamy, T.; McDonald, M.; Olivo, M.; Schmorl, P.; Yuan, D.H.L.; Asaji, T.; Sasaki, H.; Kato, Y.; Atabaev, B.; Radjabov, S.S.; Akhmadjanova, M.K.; Yuzikaeva, F.R.; Baoqun, Cui; Liqiang, Li; Yingjun, Ma; Shengyun, Zhu; Cong, Jiang

    2005-07-01

    This document gathers the summaries of the presentations made at ICIS05 (international conference on ion sources). It can be organized into 3 main topics: 1) 'fundamentals and theory' that deals with plasma, beam extraction, transport and emittance, diagnostics and simulation; 2) 'various types of ion sources' that include ECRIS, EBIS, microwave, negative, radioactive, polarized and laser ion sources, and charge breeders; and 3) 'ion sources and applications' in fields like accelerator injection, fusion energy, space propulsion, mass spectrometry, and neutron and cluster and rare nuclide production.

  13. RF synchronized short pulse laser ion source

    Energy Technology Data Exchange (ETDEWEB)

    Fuwa, Yasuhiro, E-mail: fuwa@kyticr.kuicr.kyoto-u.ac.jp; Iwashita, Yoshihisa; Tongu, Hiromu; Inoue, Shunsuke; Hashida, Masaki; Sakabe, Shuji [Institute for Chemical Research, Kyoto University, Uji, Kyoto 611-0011 (Japan); Okamura, Masahiro [Collider-Accelerator Department, Brookhaven National Laboratory, Upton, New York 11973 (United States); Yamazaki, Atsushi [Graduate School of Engineering, Nagoya University, Nagoya, Aichi 464-8603 (Japan)

    2016-02-15

    A laser ion source that produces shortly bunched ion beam is proposed. In this ion source, ions are extracted immediately after the generation of laser plasma by an ultra-short pulse laser before its diffusion. The ions can be injected into radio frequency (RF) accelerating bucket of a subsequent accelerator. As a proof-of-principle experiment of the ion source, a RF resonator is prepared and H{sub 2} gas was ionized by a short pulse laser in the RF electric field in the resonator. As a result, bunched ions with 1.2 mA peak current and 5 ns pulse length were observed at the exit of RF resonator by a probe.

  14. Electron-cyclotron-resonance ion sources (review)

    Energy Technology Data Exchange (ETDEWEB)

    Golovanivskii, K.S.; Dougar-Jabon, V.D. [People`s Friendship Univ., Moscow (Russian Federation)

    1992-01-01

    The physical principles are described and a brief survey of the present state is given of ion sources based on electron-cyclotron heating of plasma in a mirror trap. The characteristics of ECR sources of positive and negative ions used chiefly in accelerator technology are presented. 20 refs., 10 figs., 3 tabs.

  15. GANIL Workshop on Ion Sources; Journees Sources d'Ions

    Energy Technology Data Exchange (ETDEWEB)

    Leroy, Renan [Grand Accelerateur National d' Ions Lourds (GANIL), 14 - Caen (France)

    1999-07-01

    The proceedings of the GANIL Workshop on Ion Sources held at GANIL - Caen on 18-19 March 1999 contains 13 papers aiming at improving the old source operation and developing new types of sources for nuclear research and studies of ion physics. A number of reports are devoted to applications like surface treatment, ion implantation or fusion injection. The 1+{yields}n+ transformation, charged particle transport in ECR sources, addition of cesium and xenon in negative ion sources and other basic issues in ion sources are also addressed.

  16. Electron string ion sources for carbon ion cancer therapy accelerators

    Science.gov (United States)

    Boytsov, A. Yu.; Donets, D. E.; Donets, E. D.; Donets, E. E.; Katagiri, K.; Noda, K.; Ponkin, D. O.; Ramzdorf, A. Yu.; Salnikov, V. V.; Shutov, V. B.

    2015-08-01

    The type of the Electron String Ion Sources (ESIS) is considered to be the appropriate one to produce pulsed C4+ and C6+ ion beams for cancer therapy accelerators. In fact, the new test ESIS Krion-6T already now provides more than 1010 C4+ ions per pulse and about 5 × 109 C6+ ions per pulse. Such ion sources could be suitable to apply at synchrotrons. It has also been found that Krion-6T can provide more than 1011 C6+ ions per second at the 100 Hz repetition rate, and the repetition rate can be increased at the same or larger ion output per second. This makes ESIS applicable at cyclotrons as well. ESIS can be also a suitable type of ion source to produce the 11C radioactive ion beams. A specialized cryogenic cell was experimentally tested at the Krion-2M ESIS for pulse injection of gaseous species into the electron string. It has been shown in experiments with stable methane that the total conversion efficiency of methane molecules to C4+ ions reached 5%÷10%. For cancer therapy with simultaneous irradiation and precise dose control (positron emission tomography) by means of 11C, transporting to the tumor with the primary accelerated 11C4+ beam, this efficiency is preliminarily considered to be large enough to produce the 11C4+ beam from radioactive methane and to inject this beam into synchrotrons.

  17. Cold atomic beam ion source for focused ion beam applications

    Energy Technology Data Exchange (ETDEWEB)

    Knuffman, B.; Steele, A. V. [Center for Nanoscale Science and Technology, National Institute of Standards and Technology, Gaithersburg, Maryland 20899 (United States); Maryland Nanocenter, University of Maryland, College Park, Maryland 20742 (United States); zeroK NanoTech, Montgomery Village, Maryland 20886 (United States); McClelland, J. J. [Center for Nanoscale Science and Technology, National Institute of Standards and Technology, Gaithersburg, Maryland 20899 (United States)

    2013-07-28

    We report measurements and modeling of an ion source that is based on ionization of a laser-cooled atomic beam. We show a high brightness and a low energy spread, suitable for use in next-generation, high-resolution focused ion beam systems. Our measurements of total ion current as a function of ionization conditions support an analytical model that also predicts the cross-sectional current density and spatial distribution of ions created in the source. The model predicts a peak brightness of 2 × 10{sup 7} A m{sup −2} sr{sup −1} eV{sup −1} and an energy spread less than 0.34 eV. The model is also combined with Monte-Carlo simulations of the inter-ion Coulomb forces to show that the source can be operated at several picoamperes with a brightness above 1 × 10{sup 7} A m{sup −2} sr{sup −1} eV{sup −1}. We estimate that when combined with a conventional ion focusing column, an ion source with these properties could focus a 1 pA beam into a spot smaller than 1 nm. A total current greater than 5 nA was measured in a lower-brightness configuration of the ion source, demonstrating the possibility of a high current mode of operation.

  18. Off-line ion source terminal for ISAC at TRIUMF.

    Science.gov (United States)

    Jayamanna, K; Ames, F; Cojocaru, G; Baartman, R; Bricault, P; Dube, R; Laxdal, R; Marchetto, M; MacDonald, M; Schmor, P; Wight, G; Yuan, D

    2008-02-01

    The off-line ion source (OLIS) terminal consists of a microwave cusp ion source, either a surface ion source or a hybrid surface-arc discharge ion source and an electrostatic switch that allows selecting any one of the sources without mechanical intervention. These sources provide variety of beams to ISAC experiments, for commissioning the accelerators, for setting up the radioactive experiments, and for tuning the beam lines. The microwave ion source has been operational since 1995 and provides singly and doubly charged beams from various stable isotopes for many ISAC experiments at high and low energy areas. Originally its prime goal was to provide beams from gaseous elements, but later two ovens and a sputtering system were added in order to provide beams from liquids and from solids. The surface ion source installed in 2002 can provide low energy spread beams from alkali and semialkali elements. It also has three separate ovens and an ionizer. Therefore, it can provide three different temperature regions simultaneously to provide different beams to ISAC. It is mainly used for laser spectroscopy experiments and other experiments, which require a finite beam quality. A hybrid surface-arc discharge ion source was also developed and installed in order to meet specific demands from experiments. This source terminal is now automated for start up and for mass selection. It is capable of providing stable beams for months without maintenance and it is also capable of providing negative ion beams if required. To date, over 40 different isotopes including many rear isotopes were delivered to various experiments from the OLIS source terminal. Performances of the ion sources and some of the results are discussed.

  19. An overview of LINAC ion sources

    Energy Technology Data Exchange (ETDEWEB)

    Keller, Roderich [Los Alamos National Laboratory

    2008-01-01

    This paper discusses ion sources used in high-duty-factor proton and H{sup -} Linacs as well as in accelerators utilizing multi-charged heavy ions, mostly for nuclear physics applications. The included types are Electron Cyclotron Resonance (ECR) sources as well as filament and rf driven multicusp sources. The paper does not strive to attain encyclopedic character but rather to highlight major lines of development, peak performance parameters and type-specific limitations and problems of these sources. The main technical aspects being discussed are particle feed, plasma generation and ion production by discharges, and plasma confinement.

  20. Characteristics of MINI ECR ion source

    Energy Technology Data Exchange (ETDEWEB)

    Saitoh, Yuichi; Yokota, Watalu [Japan Atomic Energy Research Inst., Takasaki, Gunma (Japan). Takasaki Radiation Chemistry Research Establishment

    1997-03-01

    A very compact electron cyclotron resonance ion source (MINI ECR) was manufactured to extend available energy ranges of ion beams by applying multiply charged ions to electrostatic accelerators. The magnetic field to confine a plasma is formed only by small permanent magnets and the microwave power up to 15 W is generated by a compact transistor amplifier in order to install the ion source at a narrow high-voltage terminal where the electrical power feed is restricted. The magnet assembly is 12 cm in length and 11 cm in diameter, and forms a mirror field with the maximum strength of 0.55 T. The total power consumption of the source is below 160 W. The performance of the source was tested in a bench stand. The results of Ar, Xe, O, and N ion generation are reported in this paper. (author)

  1. ECR ion source with electron gun

    Science.gov (United States)

    Xie, Z.Q.; Lyneis, C.M.

    1993-10-26

    An Advanced Electron Cyclotron Resonance ion source having an electron gun for introducing electrons into the plasma chamber of the ion source is described. The ion source has a injection enclosure and a plasma chamber tank. The plasma chamber is defined by a plurality of longitudinal magnets. The electron gun injects electrons axially into the plasma chamber such that ionization within the plasma chamber occurs in the presence of the additional electrons produced by the electron gun. The electron gun has a cathode for emitting electrons therefrom which is heated by current supplied from an AC power supply while bias potential is provided by a bias power supply. A concentric inner conductor and outer conductor carry heating current to a carbon chuck and carbon pusher which hold the cathode in place and also heat the cathode. In the Advanced Electron Cyclotron Resonance ion source, the electron gun replaces the conventional first stage used in prior electron cyclotron resonance ion generators. 5 figures.

  2. Simulations of Beam Injection and Extraction into Ion Sources

    CERN Document Server

    Cavenago, Marco

    2005-01-01

    Charge breeding, consistiting of injecting singly charged ion into ECRIS(Electron Cyclotron Resonance Ion Sources) to extract an highly charged ion beam, is a promising technique for rare or radioactive ion beam. Efficiency and extracted beam temperature are dominated by the strong collisional diffusion of charged ion inside source. A computer code, named BEAM2ECR, written to simulate details of the injection, ionization, collision and extraction processes is described.* A model of injection plasma sheath and of source fringe field were recently added. Neutral injection is also supported, for comparison with other techniques, like gas feeding or metal vapor injection. Results, clearly favouring near axis injection for most cases are described. Code is written in C-language and possibility of concurrent execution over a Linux cluster was recently added.

  3. Highly Stripped Ion Sources for MeV Ion Implantation

    Energy Technology Data Exchange (ETDEWEB)

    Hershcovitch, Ady

    2009-06-30

    Original technical objectives of CRADA number PVI C-03-09 between BNL and Poole Ventura, Inc. (PVI) were to develop an intense, high charge state, ion source for MeV ion implanters. Present day high-energy ion implanters utilize low charge state (usually single charge) ion sources in combination with rf accelerators. Usually, a MV LINAC is used for acceleration of a few rnA. It is desirable to have instead an intense, high charge state ion source on a relatively low energy platform (de acceleration) to generate high-energy ion beams for implantation. This de acceleration of ions will be far more efficient (in energy utilization). The resultant implanter will be smaller in size. It will generate higher quality ion beams (with lower emittance) for fabrication of superior semiconductor products. In addition to energy and cost savings, the implanter will operate at a lower level of health risks associated with ion implantation. An additional aim of the project was to producing a product that can lead to long­ term job creation in Russia and/or in the US. R&D was conducted in two Russian Centers (one in Tomsk and Seversk, the other in Moscow) under the guidance ofPVI personnel and the BNL PI. Multiple approaches were pursued, developed, and tested at various locations with the best candidate for commercialization delivered and tested at on an implanter at the PVI client Axcelis. Technical developments were exciting: record output currents of high charge state phosphorus and antimony were achieved; a Calutron-Bemas ion source with a 70% output of boron ion current (compared to 25% in present state-of-the-art). Record steady state output currents of higher charge state phosphorous and antimony and P ions: P{sup 2+} (8.6 pmA), P{sup 3+} (1.9 pmA), and P{sup 4+} (0.12 pmA) and 16.2, 7.6, 3.3, and 2.2 pmA of Sb{sup 3+} Sb {sup 4 +}, Sb{sup 5+}, and Sb{sup 6+} respectively. Ultimate commercialization goals did not succeed (even though a number of the products like high

  4. Pulsed, Inductively Generated, Streaming Plasma Ion Source for Heavy Ion Fusion Linacs

    Energy Technology Data Exchange (ETDEWEB)

    Steven C. Glidden; Howard D Sanders; John B. Greenly; Daniel L. Dongwoo

    2006-04-28

    This report describes a compact, high current density, pulsed ion source, based on electrodeless, inductively driven gas breakdown, developed to meet the requirements on normalized emittance, current density, uniformity and pulse duration for an ion injector in a heavy-ion fusion driver. The plasma source produces >10 μs pulse of Argon plasma with ion current densities >100 mA/cm2 at 30 cm from the source and with strongly axially directed ion energy of about 80 eV, and sub-eV transverse temperature. The source has good reproducibility and spatial uniformity. Control of the current density during the pulse has been demonstrated with a novel modulator coil method which allows attenuation of the ion current density without significantly affecting the beam quality. This project was carried out in two phases. Phase 1 used source configurations adapted from light ion sources to demonstrate the feasibility of the concept. In Phase 2 the performance of the source was enhanced and quantified in greater detail, a modulator for controlling the pulse shape was developed, and experiments were conducted with the ions accelerated to >40 kV.

  5. ION SOURCE FOR A SINGLE PARTICLE ACCELERATOR

    Directory of Open Access Journals (Sweden)

    Tomas Matlocha

    2016-12-01

    Full Text Available This paper proposes a method to obtain very low beam current on the injection side of an particle accelerator. By using a combination of a well known ion source type and a short photo-emissive laser pulse, very low amount of ions can be created. The method could be used in the ion source of various types of the accelerators, where very low beam current is essential. The design is adapted to build a compact internal ion source and the dimensions of the device are adjusted to fit central region of the cyclotron U-120M. The functional parameters of the device are discussed and the ammount of the produced ions is estimated.

  6. ECR ion source for high current linac

    CERN Document Server

    Cui Bao Qun; Jiang Wei; LiLiQiang; WangRongWen

    2002-01-01

    An intense ECR ion source for ADS (accelerator driven sub-critical system) is described. Two configurations of the source has been developed and tested. 100 mA hydrogen beam has been extracted from the ion source at 30 keV, the proton ratio is greater than 85%, estimated emittance is 0.11 pi mm centre dot mrad, the maximum extracted beam density is 340 mA/cm sup 2 . A 100 hours reliability test of the source is also described

  7. Ion Behavior and Gas Mixing in electron cyclotron resonance plasmas as sources of highly charged ions (concept)

    CERN Document Server

    Melin, G; Girard, A; Hitz, D

    1999-01-01

    An ECR ion source is basically an ECR heated plasma confinement machine, with hot electrons and cold ions. The main parameters of the ion population have been analyzed, including temperature, losses, and confinement time. The "gas mixing" effect has been studied in this context. An expression is derived for determining the ion temperature from the values of all extracted ion currents. One aim is to study the ion temperature behavior in argon plasmas without and with mixing different gases into the plasma. For that purpose a series of experiments has been performed where systematically one or a few parameters where changed. One conclusion is that the ion temperature indeed is decreasing due to gas mixing. A second conclusion is that the decreasing ion temperature is not a sufficient requirement for the beneficial effect of gas mixing to the production of highest charge states of argon.

  8. Negative hydrogen ion sources for accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Moehs, D.P.; /Fermilab; Peters, J.; /DESY; Sherman, J.; /Los Alamos

    2005-08-01

    A variety of H{sup -} ion sources are in use at accelerator laboratories around the world. A list of these ion sources includes surface plasma sources with magnetron, Penning and surface converter geometries as well as magnetic-multipole volume sources with and without cesium. Just as varied is the means of igniting and maintaining magnetically confined plasmas. Hot and cold cathodes, radio frequency, and microwave power are all in use, as well as electron tandem source ignition. The extraction systems of accelerator H{sup -} ion sources are highly specialized utilizing magnetic and electric fields in their low energy beam transport systems to produce direct current, as well as pulsed and/or chopped beams with a variety of time structures. Within this paper, specific ion sources utilized at accelerator laboratories shall be reviewed along with the physics of surface and volume H{sup -} production in regard to source emittance. Current research trends including aperture modeling, thermal modeling, surface conditioning, and laser diagnostics will also be discussed.

  9. ECRIS as ion source and charge breeder

    CERN Document Server

    Sortais, P; Chauvin, N; Curdy, Jean Claude; Geller, R; Lamy, T; Solé, P; Vieux-Rochaz, J L

    2002-01-01

    We will recall the main characteristics of ECR ion sources and their very good property of ionization efficiency. We will start with a review of on line use of ECR ion sources for production of mono or multicharged radioactive ions, and then we will specially focus our attention on charge breeding process for multicharged ion production. Initially developed for the PIAFE project from ISN Grenoble, the ECR charge breeder shows that the beam injection of a primary beam inside an ECR ion source is a very general process for beam production. We will review the latest results obtained on the ISN Grenoble test bench for the production of CW or pulsed metallic ion beams with the so called '1 sup + /n sup + ' method. New results are given for CW operation where the efficiency is particularly optimized for application to multicharged radioactive ion production (for example, 3.5% for Zn sup 1 sup +->Zn sup 9 sup + , 4.2% for Pb sup 3 sup +->Pb sup 2 sup 4 sup + , 5% for Rb sup 1 sup +->Rb sup 1 sup 5 sup +). Different ...

  10. Low Z impurity ion extraction from TFTR ion sources

    Energy Technology Data Exchange (ETDEWEB)

    Kamperschroer, J.H.; Grisham, L.R.; Newman, R.A.; O' Connor, T.E.; Stevenson, T.N.; von Halle, A.; Williams, M.D.; Wright, K.E.

    1993-04-01

    TFTR deuterium neutral beams have been operated unintentionally with significant quantities of extracted water ions. Water has been observed with an Optical Multichannel Analyzer (OMA) during beam extraction when small water leaks were present within the arc chamber. These leaks were thermally induced with the contamination level increasing linearly with pulse length. 6% of the beam current was attributed to water ions for the worst leak, corresponding to an instantaneous value of 12% at the end of a 1.5 s pulse. A pre-calorimeter collimator was damaged as a result of this operation. A similar contamination is observed during initial operation of ion sources exposed to air. This latter contamination is attributed to the synthesis, from adsorbed air, of either D[sub 2]O or the indistinguishable ND[sub 3]. Initial operation of new ion sources typically produces a contamination level of [approximately]2%. These impurities are reduced to undetectable levels after 50 to 100 beam pulses. Once a water molecule is present in the plasma generator, it is predominantly ionized rather than dissociated, resulting in the extraction of only trace amounts of hydrogenated ions. The addition of water to the extracted beam also reduces the optimum perveance, moving the typical underdense operating point closer to optimum, causing the frequency of grid faults to increase. Close to 90% of the water extracted from ion sources with water leaks was deuterated, implying that the potential exists for the production of tritiated water during TFTR's forthcoming DT operation. Isotope exchange in the plasma generator takes place rapidly and is believed to be surface catalyzed. The primary concern is with O implanted into beam absorbers recombining with tritium, and the subsequent hold up of T[sub 2]O on cryopanels. Continuous surveillance with the OMA diagnostic during DT operation will ensure that ion sources with detectable water are not operated with tritium.

  11. Low Z impurity ion extraction from TFTR ion sources

    Energy Technology Data Exchange (ETDEWEB)

    Kamperschroer, J.H.; Grisham, L.R.; Newman, R.A.; O`Connor, T.E.; Stevenson, T.N.; von Halle, A.; Williams, M.D.; Wright, K.E.

    1993-04-01

    TFTR deuterium neutral beams have been operated unintentionally with significant quantities of extracted water ions. Water has been observed with an Optical Multichannel Analyzer (OMA) during beam extraction when small water leaks were present within the arc chamber. These leaks were thermally induced with the contamination level increasing linearly with pulse length. 6% of the beam current was attributed to water ions for the worst leak, corresponding to an instantaneous value of 12% at the end of a 1.5 s pulse. A pre-calorimeter collimator was damaged as a result of this operation. A similar contamination is observed during initial operation of ion sources exposed to air. This latter contamination is attributed to the synthesis, from adsorbed air, of either D{sub 2}O or the indistinguishable ND{sub 3}. Initial operation of new ion sources typically produces a contamination level of {approximately}2%. These impurities are reduced to undetectable levels after 50 to 100 beam pulses. Once a water molecule is present in the plasma generator, it is predominantly ionized rather than dissociated, resulting in the extraction of only trace amounts of hydrogenated ions. The addition of water to the extracted beam also reduces the optimum perveance, moving the typical underdense operating point closer to optimum, causing the frequency of grid faults to increase. Close to 90% of the water extracted from ion sources with water leaks was deuterated, implying that the potential exists for the production of tritiated water during TFTR`s forthcoming DT operation. Isotope exchange in the plasma generator takes place rapidly and is believed to be surface catalyzed. The primary concern is with O implanted into beam absorbers recombining with tritium, and the subsequent hold up of T{sub 2}O on cryopanels. Continuous surveillance with the OMA diagnostic during DT operation will ensure that ion sources with detectable water are not operated with tritium.

  12. Trapped individual ion at absolute zero temperature

    Science.gov (United States)

    Yu, Nan; Dehmelt, Hans; Nagourney, Warren

    1989-01-01

    Laser cooling and ion trapping have progressed to such an extent that one can now speak of realizing a confined atom at absolute zero temperature. In this short publication, we analyze an experiment toward such realization using a single Ba+ ion in a miniature rf trap. The Ba+ ion is first laser-cooled to the limit where the ion spends most of its time in the zero-point energy state. Then a test sequence allows one to verify whether or not the ion is actually in its zero-point state. The test sequence may also serve as a device for state selection of an atom at absolute zero temperature. PMID:16594054

  13. Ion Behavior and Gas Mixing in electron cyclotron resonance plasmas as sources of highly charged ions (concept

    NARCIS (Netherlands)

    Melin, G.; Drentje, A. G.; Girard, A.; Hitz, D.

    1999-01-01

    Abstract: An ECR ion source is basically an ECR heated plasma confinement machine, with hot electrons and cold ions. The main parameters of the ion population have been analyzed, including temperature, losses, and confinement time. The "gas mixing" effect has been studied in this context. An

  14. A 1D ion species model for an RF driven negative ion source

    Science.gov (United States)

    Turner, I.; Holmes, A. J. T.

    2017-08-01

    A one-dimensional model for an RF driven negative ion source has been developed based on an inductive discharge. The RF source differs from traditional filament and arc ion sources because there are no primary electrons present, and is simply composed of an antenna region (driver) and a main plasma discharge region. However the model does still make use of the classical plasma transport equations for particle energy and flow, which have previously worked well for modelling DC driven sources. The model has been developed primarily to model the Small Negative Ion Facility (SNIF) ion source at CCFE, but may be easily adapted to model other RF sources. Currently the model considers the hydrogen ion species, and provides a detailed description of the plasma parameters along the source axis, i.e. plasma temperature, density and potential, as well as current densities and species fluxes. The inputs to the model are currently the RF power, the magnetic filter field and the source gas pressure. Results from the model are presented and where possible compared to existing experimental data from SNIF, with varying RF power, source pressure.

  15. Plasma ion sources and ion beam technology inmicrofabrications

    Energy Technology Data Exchange (ETDEWEB)

    Ji, Lili [Univ. of California, Berkeley, CA (United States)

    2007-01-01

    For over decades, focused ion beam (FIB) has been playing a very important role in microscale technology and research, among which, semiconductor microfabrication is one of its biggest application area. As the dimensions of IC devices are scaled down, it has shown the need for new ion beam tools and new approaches to the fabrication of small-scale devices. In the meanwhile, nanotechnology has also deeply involved in material science research and bioresearch in recent years. The conventional FIB systems which utilize liquid gallium ion sources to achieve nanometer scale resolution can no longer meet the various requirements raised from such a wide application area such as low contamination, high throughput and so on. The drive towards controlling materials properties at nanometer length scales relies on the availability of efficient tools. In this thesis, three novel ion beam tools have been developed and investigated as the alternatives for the conventional FIB systems in some particular applications. An integrated focused ion beam (FIB) and scanning electron microscope (SEM) system has been developed for direct doping or surface modification. This new instrument employs a mini-RF driven plasma source to generate focused ion beam with various ion species, a FEI two-lens electron (2LE) column for SEM imaging, and a five-axis manipulator system for sample positioning. An all-electrostatic two-lens column has been designed to focus the ion beam extracted from the source. Based on the Munro ion optics simulation, beam spot sizes as small as 100 nm can be achieved at beam energies between 5 to 35 keV if a 5 μm-diameter extraction aperture is used. Smaller beam spot sizes can be obtained with smaller apertures at sacrifice of some beam current. The FEI 2LE column, which utilizes Schottky emission, electrostatic focusing optics, and stacked-disk column construction, can provide high-resolution (as small as 20 nm) imaging capability, with fairly long working distance (25

  16. Ion source design for industrial applications

    Science.gov (United States)

    Kaufman, H. R.; Robinson, R. S.

    1981-01-01

    The more frequently used design techniques for the components of broad-beam electron bombardment ion sources are discussed. The approach used emphasizes refractory metal cathodes and permanent-magnet multipole discharge chambers. Design procedures and sample calculations are given for the discharge chamber, ion optics, the cathodes, and the magnetic circuit. Hardware designs are included for the isolator, cathode supports, anode supports, pole-piece assembly, and ion-optics supports. A comparison is made between two-grid and three-grid optics. The designs presented are representative of current technology and are adaptable to a wide range of configurations.

  17. The RHIC polarized H⁻ ion source.

    Science.gov (United States)

    Zelenski, A; Atoian, G; Raparia, D; Ritter, J; Steski, D

    2016-02-01

    A novel polarization technique had been successfully implemented for the Relativistic Heavy Ion Collider (RHIC) polarized H(-) ion source upgrade to higher intensity and polarization. In this technique, a proton beam inside the high magnetic field solenoid is produced by ionization of the atomic hydrogen beam (from external source) in the He-gaseous ionizer cell. Further proton polarization is produced in the process of polarized electron capture from the optically pumped Rb vapor. The use of high-brightness primary beam and large cross sections of charge-exchange cross sections resulted in production of high intensity H(-) ion beam of 85% polarization. The source very reliably delivered polarized beam in the RHIC Run-2013 and Run-2015. High beam current, brightness, and polarization resulted in 75% polarization at 23 GeV out of Alternating Gradient Synchrotron (AGS) and 60%-65% beam polarization at 100-250 GeV colliding beams in RHIC.

  18. Optical surfacing via linear ion source

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Lixiang, E-mail: wulx@hdu.edu.cn [Key Lab of RF Circuits and Systems of Ministry of Education, Zhejiang Provincial Key Lab of LSI Design, Microelectronics CAD Center, College of Electronics and Information, Hangzhou Dianzi University, Hangzhou (China); Wei, Chaoyang, E-mail: siomwei@siom.ac.cn [Key Laboratory of Materials for High Power Laser, Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Shanghai 201800 (China); Shao, Jianda, E-mail: jdshao@siom.ac.cn [Key Laboratory of Materials for High Power Laser, Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Shanghai 201800 (China)

    2017-04-15

    We present a concept of surface decomposition extended from double Fourier series to nonnegative sinusoidal wave surfaces, on the basis of which linear ion sources apply to the ultra-precision fabrication of complex surfaces and diffractive optics. The modified Fourier series, or sinusoidal wave surfaces, build a relationship between the fabrication process of optical surfaces and the surface characterization based on power spectral density (PSD) analysis. Also, we demonstrate that the one-dimensional scanning of linear ion source is applicable to the removal of mid-spatial frequency (MSF) errors caused by small-tool polishing in raster scan mode as well as the fabrication of beam sampling grating of high diffractive uniformity without a post-processing procedure. The simulation results show that optical fabrication with linear ion source is feasible and even of higher output efficiency compared with the conventional approach.

  19. Optimization of a hot-cavity type resonant ionization laser ion source

    Energy Technology Data Exchange (ETDEWEB)

    Henares, J. L., E-mail: henares@ganil.fr; Lecesne, N.; Hijazi, L.; Bastin, B.; Leroy, R.; Osmond, B.; Vignet, J. L. [GANIL, BP 55027, 14076 Caen Cedex 5 (France); Kron, T.; Naubereit, P.; Wendt, K. [Johannes Gutenberg-Universität Mainz, Staudinger Weg 7, 55099 Mainz (Germany); Lassen, J. [TRIUMF, 4004 Wesbrook Mall, Vancouver, British Columbia V6T 2A3 (Canada); Le Blanc, F. [IPN Orsay, BP 1-91406 Orsay (France)

    2016-02-15

    Resonant Ionization Laser Ion Source (RILIS) is nowadays an important technique in many Radioactive Ion Beam (RIB) facilities for its reliability and ability to ionize efficiently and element selectively. Grand Accélérateur National d’Ions Lourds (GANIL) Ion Source using Electron Laser Excitation (GISELE) is an off-line test bench for RILIS developed to study a fully operational resonant laser ion source at GANIL facility. The ion source body has been designed as a modular system to investigate different experimental approaches by varying the design parameters, to develop the future on-line laser ion source. The aim of this project is to determine the best technical solution which combines high selectivity and ionization efficiency with small ion beam emittance and stable long term operation. Latest results concerning emittance and time profile development as a function of the temperature for different ion source versions will be presented.

  20. The negative ion source test facility ELISE

    Energy Technology Data Exchange (ETDEWEB)

    Heinemann, B., E-mail: bernd.heinemann@ipp.mpg.de [Max-Planck-Institut fuer Plasmaphysik, EURATOM Association, Postfach 1533, D-85748 Garching (Germany); Falter, H.-D.; Fantz, U.; Franzen, P.; Froeschle, M.; Kraus, W.; Martens, C.; Nocentini, R.; Riedl, R.; Speth, E.; Staebler, A. [Max-Planck-Institut fuer Plasmaphysik, EURATOM Association, Postfach 1533, D-85748 Garching (Germany)

    2011-10-15

    The ITER neutral beam system is using inductively coupled radio frequency (RF) ion sources, that have demonstrated the required ITER parameters on (small) sources with extraction areas up to 200 cm{sup 2}. As a next step towards the full size ITER source IPP is presently constructing the test facility ELISE ('Extraction from a Large Ion Source Experiment') operating with a 'half-size' source which has approximately the width but only half the height of the ITER source. The modular driver concept is expected to allow a further extrapolation to the full size in one direction to be made. The main aim of this experiment is to demonstrate the production of a large uniform negative ion beam with ITER relevant parameters in stable conditions up to one hour. Plasma operation of the source is foreseen to be performed continuously for 1 h; extraction and acceleration of negative ions up to 60 kV is only possible in pulsed mode (10 s every 180 s) due to limitations of the existing IPP HV system. The design of the source and extraction system implements a high experimental flexibility and a good diagnostic access while still staying as close as possible to the ITER design. The main differences are the source operating in air and the use of a large gate valve between the source and the target chamber. ELISE is expected to start operation at the end of 2011 and is an important step for the development of the ITER NBI system; the experience gained early will support the design as well as the commissioning and operating phases of the PRIMA NBI test facilities and the ITER neutral beam system.

  1. Negative Ion Sources: Magnetron and Penning

    CERN Document Server

    Faircloth, D.C.

    2013-12-16

    The history of the magnetron and Penning electrode geometry is briefly outlined. Plasma generation by electrical discharge-driven electron impact ionization is described and the basic physics of plasma and electrodes relevant to magnetron and Penning discharges are explained. Negative ions and their applications are introduced, along with their production mechanisms. Caesium and surface production of negative ions are detailed. Technical details of how to build magnetron and Penning surface plasma sources are given, along with examples of specific sources from around the world. Failure modes are listed and lifetimes compared.

  2. Recent negative ion source activity at JYFL

    Science.gov (United States)

    Kalvas, T.; Tarvainen, O.; Komppula, J.; Laitinen, M.; Sajavaara, T.; Koivisto, H.; Jokinen, A.; Dehnel, M. P.

    2013-02-01

    A filament-powered multicusp ion source for production of H- has been developed for the Jyväskylä Pelletron accelerator for use in ion beam lithography and particle induced X-ray emission applications. The source can be considered conventional with the exception of the filter field being created with an electric magnet for continuous adjustability. A permanent magnet dipoleantidipole electron dump is integrated in the puller electrode. The source provides 50 μA H- beam at 10 keV energy with 0.019 mm mrad 95 % normalized rms emittance through a 2 mm aperture. Lower emittance is achievable by changing the plasma electrode insert to a smaller aperture one if application requires. A new commercial MCC30/15 cyclotron has been installed at the Jyväskylä accelerator laboratory providing 30MeV H+ and 15Mev D+ for use in nuclear physics experiments and applications. The ion source delivered with the cyclotron is a a filament-powered multicusp source capable of about 130 h continuous operation at 1 mA H- output between filament changes. The ion source is located in the cyclotron vault and therefore a significant waiting time for the vault cooldown is required before filament change is possible. This kind of operation is not acceptable as 350 h and longer experiments are expected. Therefore a project for developing a CW 13.56 MHz RF ion source has been initiated. A planar RF antenna replacing the filament back plate of the existing TRIUMF-type ion source has been used in the first tests with 240 μA of H- and 21 mA of electrons measured at 1.5 kW of RF power. Tests with higher RF power levels were prevented by electron beam induced sparking. A new plasma chamber has been built and a new extraction is being designed for the RF ion source. The extraction code IBSimu has recently gone through a major update on how smooth electrode surfaces are implemented in the Poisson solvers. This has made it possible to implement a fast multigrid solver with low memory consumption. Also

  3. Development of versatile multiaperture negative ion sources

    Science.gov (United States)

    Cavenago, M.; Serianni, G.; Antoni, V.; Bigi, M.; De Muri, M.; Pasqualotto, R.; Recchia, M.; Veltri, P.; Agostinetti, P.; Barbisan, M.; Baseggio, L.; Cervaro, V.; Cazzador, M.; Degli Agostini, F.; Franchin, L.; Kulevoy, T.; Laterza, B.; Mimo, A.; Minarello, A.; Petrenko, S.; Ravarotto, D.; Rossetto, F.; Sattin, M.; Zaniol, B.; Zucchetti, S.

    2015-04-01

    Enhancement of negative ion sources for production of large ion beams is a very active research field nowadays, driven from demand of plasma heating in nuclear fusion devices and accelerator applications. As a versatile test bench, the ion source NIO1 (Negative Ion Optimization 1) is being commissioned by Consorzio RFX and INFN. The nominal beam current of 135 mA at -60 kV is divided into 9 beamlets, with multiaperture extraction electrodes. The plasma is sustained by a 2 MHz radiofrequency power supply, with a standard matching box. A High Voltage Deck (HVD) placed inside the lead shielding surrounding NIO1 contains the radiofrequency generator, the gas control, electronics and power supplies for the ion source. An autonomous closed circuit water cooling system was installed for the whole system, with a branch towards the HVD, using carefully optimized helical tubing. Insulation transformer is installed in a nearby box. Tests of several magnetic configurations can be performed. Status of experiments, measured spectra and plasma luminosity are described. Upgrades of magnetic filter, beam calorimeter and extraction grid and related theoretical issues are reviewed.

  4. Development of Li+ alumino-silicate ion source

    Energy Technology Data Exchange (ETDEWEB)

    Roy, P.K.; Seidl, P.A.; Waldron, W.; Greenway, W.; Lidia, S.; Anders, A.; Kwan, J.

    2009-04-21

    To uniformly heat targets to electron-volt temperatures for the study of warm dense matter, one strategy is to deposit most of the ion energy at the peak of energy loss (dE/dx) with a low (E< 5 MeV) kinetic energy beam and a thin target[1]. Lower mass ions have a peak dE/dx at a lower kinetic energy. To this end, a small lithium (Li+) alumino-silicate source has been fabricated, and its emission limit has been measured. These surface ionization sources are heated to 1000-1150 C where they preferentially emit singly ionized alkali ions. Alumino-silicates sources of K+ and Cs+ have been used extensively in beam experiments, but there are additional challenges for the preparation of high-quality Li+ sources: There are tighter tolerances in preparing and sintering the alumino-silicate to the substrate to produce an emitter that gives uniform ion emission, sufficient current density and low beam emittance. We report on recent measurements ofhigh ( up to 35 mA/cm2) current density from a Li+ source. Ion species identification of possible contaminants is being verified with a Wien (E x B) filter, and via time-of-flight.

  5. Three-dimensional simulations of ion dynamics in an Electron Cyclotron Resonance Ion Source

    NARCIS (Netherlands)

    Beijers, J. P. M.; Mironov, V.

    We present a three-dimensional simulation of the ion dynamics in an electron cyclotron resonance ion source. Ion trajectories in the min-B field of the source are calculated taking ion-ion and electron-ion collisions into account. The electrons are not tracked but considered as a neutralizing

  6. Status of ECR ion sources at JAERI

    CERN Document Server

    Yokota, W; Nara, T; Ishi, Y; Arakawa, K; Ohkoshi, K

    1999-01-01

    At the Takasaki site of Japan Atomic Energy Research Institute, four ECR ion sources were purchased or developed so far. This paper will report their performance, modification and status. The outlines for each source are as follows; 1. OCTOPUS purchased from IBA s.a. has been in use with a cyclotron since 1990. The gas feed system was modified to change gas species within 10 minutes to avoid impurity ions in the cocktail beam acceleration technique of the cyclotron. 2. ECR-18 with 18-GHz microwave has a solenoid coil between a pair of mirror coils to change mirror ratio in a wide range. A bump between mirror peaks in the original axial field distribution was removed by halving the solenoid length. The performance in generating high charge state ions was significantly improved as a result. 3. HYPERNANOGAN was purchased from PANTECHNIK s.a. and installed in the cyclotron system this year. Test operation was successfully made with generation of Ar, Pb and Ta ions. 4. MINI ECR is a full permanent magnet source wi...

  7. Recent progress on the superconducting ion source VENUS.

    Science.gov (United States)

    Benitez, J Y; Franzen, K Y; Hodgkinson, A; Loew, T; Lyneis, C M; Phair, L; Saba, J; Strohmeier, M; Tarvainen, O

    2012-02-01

    The 28 GHz Ion Source VENUS (versatile ECR for nuclear science) is back in operation after the superconducting sextupole leads were repaired and a fourth cryocooler was added. VENUS serves as an R&D device to explore the limits of electron cyclotron resonance source performance at 28 GHz with its 10 kW gryotron and optimum magnetic fields and as an ion source to increase the capabilities of the 88-Inch Cyclotron both for nuclear physics research and applications. The development and testing of ovens and sputtering techniques cover a wide range of applications. Recent experiments on bismuth demonstrated stable operation at 300 eμA of Bi(31+), which is in the intensity range of interest for high performance heavy-ion drivers such as FRIB (Facility for Rare Isotope Beams). In addition, the space radiation effects testing program at the cyclotron relies on the production of a cocktail beam with many species produced simultaneously in the ion source and this can be done with a combination of gases, sputter probes, and an oven. These capabilities are being developed with VENUS by adding a low temperature oven, sputter probes, as well as studying the RF coupling into the source.

  8. Recent progress on the superconducting ion source VENUS

    Energy Technology Data Exchange (ETDEWEB)

    Benitez, J. Y.; Franzen, K. Y.; Hodgkinson, A.; Loew, T.; Lyneis, C. M.; Phair, L.; Saba, J.; Strohmeier, M. [Nuclear Science Division, Lawrence Berkeley National Laboratory, Berkeley, California 94720 (United States); Tarvainen, O. [Accelerator Laboratory, Department of Physics, University of Jyvaeskylae, FIN-40014 (Finland)

    2012-02-15

    The 28 GHz Ion Source VENUS (versatile ECR for nuclear science) is back in operation after the superconducting sextupole leads were repaired and a fourth cryocooler was added. VENUS serves as an R and D device to explore the limits of electron cyclotron resonance source performance at 28 GHz with its 10 kW gryotron and optimum magnetic fields and as an ion source to increase the capabilities of the 88-Inch Cyclotron both for nuclear physics research and applications. The development and testing of ovens and sputtering techniques cover a wide range of applications. Recent experiments on bismuth demonstrated stable operation at 300 e{mu}A of Bi{sup 31+}, which is in the intensity range of interest for high performance heavy-ion drivers such as FRIB (Facility for Rare Isotope Beams). In addition, the space radiation effects testing program at the cyclotron relies on the production of a cocktail beam with many species produced simultaneously in the ion source and this can be done with a combination of gases, sputter probes, and an oven. These capabilities are being developed with VENUS by adding a low temperature oven, sputter probes, as well as studying the RF coupling into the source.

  9. Ion source antenna development for the Spallation Neutron Source

    Science.gov (United States)

    Welton, R. F.; Stockli, M. P.; Kang, Y.; Janney, M.; Keller, R.; Thomae, R. W.; Schenkel, T.; Shukla, S.

    2002-02-01

    The operational lifetime of a radio-frequency (rf) ion source is generally governed by the length of time the insulating structure protecting the antenna survives during exposure to the plasma. Coating the antenna with a thin layer of insulating material is a common means of extending the life of such antennas. When low-power/low-duty factor rf excitation is employed, antenna lifetimes of several hundred hours are typical. When high-power, >30 kW, and high-duty cycles, ˜6%, are employed, as is the case of the Spallation Neutron Source (SNS) ion source, antenna lifetime becomes unacceptably short. This work addresses this problem by first showing the results of microanalysis of failed antennas from the SNS ion source, developing a model of the damage mechanism based on plasma-insulator interaction, using the model to determine the dimensional and material properties of an ideal coating, and describing several approaches currently under way to develop a long-lived antenna for the SNS accelerator. These approaches include thermal spray coatings, optimized porcelain enamel coatings, refractory enamel coatings, and novel antenna geometries designed to operate with low rf electric fields.

  10. Proton emission from a laser ion source

    Energy Technology Data Exchange (ETDEWEB)

    Torrisi, L. [INFN-LNS Via S. Sofia 44, 95123 Catania (Italy); Dip.to di Fisica, Universita di Messina, V.le F.S. D' Alcontres 31, 98166 S. Agata, Messina (Italy); Cavallaro, S.; Gammino, S. [INFN-LNS Via S. Sofia 44, 95123 Catania (Italy); Cutroneo, M. [Dip.to di Fisica, Universita di Messina, V.le F.S. D' Alcontres 31, 98166 S. Agata, Messina (Italy); Margarone, D. [Institute of Physics, ASCR, v.v.i., 182 21 Prague 8 (Czech Republic)

    2012-02-15

    At intensities of the order of 10{sup 10} W/cm{sup 2}, ns pulsed lasers can be employed to ablate solid bulk targets in order to produce high emission of ions at different charge state and kinetic energy. A special interest is devoted to the production of protons with controllable energy and current from a roto-translating target irradiated in repetition rate at 1-10 Hz by a Nd:Yag pulsed laser beam. Different hydrogenated targets based on polymers and hydrates were irradiated in high vacuum. Special nanostrucutres can be embedded in the polymers in order to modify the laser absorption properties and the amount of protons to be accelerated in the plasma. For example, carbon nanotubes may increase the laser absorption and the hydrogen absorption to generate high proton yields from the plasma. Metallic nanostrucutres may increase the electron density of the plasma and the kinetic energy of the accelerated protons. Ion collectors, ion energy analyzer, and mass spectrometers, used in time-of-flight configuration, were employed to characterize the ion beam properties. A comparison with traditional proton ion source is presented and discussed.

  11. Proton emission from a laser ion source.

    Science.gov (United States)

    Torrisi, L; Cavallaro, S; Cutroneo, M; Margarone, D; Gammino, S

    2012-02-01

    At intensities of the order of 10(10) W∕cm(2), ns pulsed lasers can be employed to ablate solid bulk targets in order to produce high emission of ions at different charge state and kinetic energy. A special interest is devoted to the production of protons with controllable energy and current from a roto-translating target irradiated in repetition rate at 1-10 Hz by a Nd:Yag pulsed laser beam. Different hydrogenated targets based on polymers and hydrates were irradiated in high vacuum. Special nanostrucutres can be embedded in the polymers in order to modify the laser absorption properties and the amount of protons to be accelerated in the plasma. For example, carbon nanotubes may increase the laser absorption and the hydrogen absorption to generate high proton yields from the plasma. Metallic nanostrucutres may increase the electron density of the plasma and the kinetic energy of the accelerated protons. Ion collectors, ion energy analyzer, and mass spectrometers, used in time-of-flight configuration, were employed to characterize the ion beam properties. A comparison with traditional proton ion source is presented and discussed.

  12. CAS Accelerator Physics (Ion Sources) in Slovakia

    CERN Multimedia

    CAS School

    2012-01-01

    The CERN Accelerator School (CAS) and the Slovak University of Technology jointly organised a specialised course on ion sources, held at the Hotel Senec, Senec, Slovakia, from 29 May to 8 June, 2012.   Following some background lectures on accelerator physics and the fundamental processes of atomic and plasma physics, the course covered a wide range of topics related to ion sources and highlighted the latest developments in the field. Realistic case studies and topical seminars completed the programme. The school was very successful, with 69 participants representing 25 nationalities. Feedback from the participants was extremely positive, reflecting the high standard of the lectures. The case studies were performed with great enthusiasm and produced some excellent results. In addition to the academic programme, the participants were able to take part in a one-day excursion consisting of a guided tour of Bratislava and free time. A welcome event was held at the Hotel Senec, with s...

  13. Heavy Ion Injection Into Synchrotrons, Based On Electron String Ion Sources

    CERN Document Server

    Donets, E E; Syresin, E M

    2004-01-01

    A possibility of heavy ions injection into synchrotrons is discussed on the base of two novel ion sources, which are under development JINR during last decade: 1) the electron string ion source (ESIS), which is a modified version of a conventional electron beam ion source (EBIS), working in a reflex mode of operation, and 2) the tubular electron string ion source (TESIS). The Electron String Ion Source "Krion-2" (VBLHE, JINR, Dubna) with an applied confining magnetic field of 3 T was used for injection into the superconducting JINR synchrotron - Nuclotron and during this runs the source provided a high pulse intensity of the highly charged ion beams: Ar16+

  14. Ion trajectories in atom probe field ion microscopy and gas field ion sources

    CERN Document Server

    Castilho, C M C

    1999-01-01

    Trajectories of positive ions produced in a region close to a structured surface, modelled by spherical or spheroidal protrusions and kept at a positive electric potential with respect to a distant screen or detector are calculated. The results are discussed in comparison with similar practical situations produced by field ionization and field evaporation or desorption, such as those occurring in gas field ion sources, field ion microscopy and field desorption spectroscopy. (author)

  15. Alkali suppression within laser ion-source cavities and time structure of the laser ionized ion-bunches

    CERN Document Server

    Lettry, Jacques; Köster, U; Georg, U; Jonsson, O; Marzari, S; Fedosseev, V

    2003-01-01

    The chemical selectivity of the target and ion-source production system is an asset for Radioactive Ion-Beam (RIB) facilities equipped with mass separators. Ionization via laser induced multiple resonant steps Ionization has such selectivity. However, the selectivity of the ISOLDE Resonant Ionization Laser Ion-Source (RILIS), where ionization takes place within high temperature refractory metal cavities, suffers from unwanted surface ionization of low ionization potential alkalis. In order to reduce this type of isobaric contaminant, surface ionization within the target vessel was used. On-line measurements of the efficiency of this method is reported, suppression factors of alkalis up to an order of magnitude were measured as a function of their ionization potential. The time distribution of the ion bunches produced with the RILIS was measured for a variety of elements and high temperature cavity materials. While all ions are produced within a few nanoseconds, the ion bunch sometimes spreads over more than 1...

  16. Beam optics optimization of a negative-ion sputter source

    Indian Academy of Sciences (India)

    Finally, we propose some fundamental modifications of the source to prepare future needs. 2. Description of the negative-ion sputter source. Figure 1 shows the configuration of our 860 ST model negative-ion source. The ion- izer has an elliptical surface made of molybdenum mounted in axial alignment with a. 795 ...

  17. New Results with the superconducting ECR ion source VENUS

    Energy Technology Data Exchange (ETDEWEB)

    Lyneis, C.M.; Leitner, D.; Abbott, S.R.; Dwinell, R.D.; Leitner,M.; Silver, C.S.; Taylor, C.

    2004-05-13

    During the last year, the VENUS ECR ion source was commissioned at 18 GHz and preparations for 28 GHz operation, which is set to begin early in 2004, are now underway. The goal of the VENUS ECR ion source project as the RIA R&D injector is the production of 240emA of U30+, a high current medium charge state beam. On the other hand, as an injector ion source for the 88-Inch Cyclotron the design objective is the production of 5emA of U48+, a low current, very high charge state beam. During the commissioning phase with 18 GHz, tests with various gases and recently metals have been performed with up to 2000 W RF power and the performance is very promising. For example, 1100 e mu A of O6+,180 e mu A of Ar12+, 150 emA of Xe20+ and 100 emA of Bi24+ were produced in the early commissioning phase, ranking VENUS among the currently highest performance 18 GHz ECR ion sources. The emittance of the beams produced at 18 GHz was measured with a two axis emittance scanner. In FY04 a 10 kW, 28 GHz gyrotron system will be added, which will enable VENUS to reach full performance. The performance of the VENUS ion source, low energy beam transport (LEBT) and its closed loop cryogenic system are described in the paper. Recently, a new high temperature axial oven has been installed in the source and the first results on metal beams such as bismuth are given. The design of the 28 GHz, 10 kW gyrotron system is also be described. During the last year, the VENUS ECR ion source was commissioned at 18 GHz and preparations for 28 GHz operation, which is set to begin early in 2004, are now underway. The goal of the VENUS ECR+, a high current medium charge state beam. On the other hand, as an injector ion source for the 88-Inch Cyclotron the design objective is the production of 5 emA of U48+, a low current, very high charge state beam. During the commissioning phase with 18 GHz, tests with various gases and recently metals have been performed with up to 2000 W RF power and the performance is

  18. MIVOC method at the mVINIS ion source

    Directory of Open Access Journals (Sweden)

    Jovović Jovica

    2007-01-01

    Full Text Available Based on the metal-ions-from-volatile-compounds (MIVOC method with the mVINIS ion source, we have produced multiply charged ion beams from solid substances. Highly in tense, stable multiply charged ion beams of several solid substances with high melting points were extracted by using this method. The spectrum of multiply charged ion beams obtained from the element hafnium is presented here. For the first time ever, hafnium ion beam spectra were recorded at an electron cyclotron resonance ion source. Multiply charged ion beams from solid substances were used to irradiate the polymer, fullerene and glassy carbon samples at the channel for the modification of materials.

  19. A hollow cathode ion source for production of primary ions for the BNL electron beam ion source

    Energy Technology Data Exchange (ETDEWEB)

    Alessi, James, E-mail: alessi@bnl.gov; Beebe, Edward; Carlson, Charles; McCafferty, Daniel; Pikin, Alexander; Ritter, John [Collider-Accelerator Department, Brookhaven National Laboratory, Upton, New York 11973 (United States)

    2014-02-15

    A hollow cathode ion source, based on one developed at Saclay, has been modified significantly and used for several years to produce all primary 1+ ions injected into the Relativistic Heavy Ion Collider Electron Beam Ion Source (EBIS) at Brookhaven. Currents of tens to hundreds of microamperes have been produced for 1+ ions of He, C, O, Ne, Si, Ar, Ti, Fe, Cu, Kr, Xe, Ta, Au, and U. The source is very simple, relying on a glow discharge using a noble gas, between anode and a solid cathode containing the desired species. Ions of both the working gas and ionized sputtered cathode material are extracted, and then the desired species is selected using an ExB filter before being transported into the EBIS trap for charge breeding. The source operates pulsed with long life and excellent stability for most species. Reliable ignition of the discharge at low gas pressure is facilitated by the use of capacitive coupling from a simple toy plasma globe. The source design, and operating experience for the various species, is presented.

  20. Linac4 H{sup −} ion sources

    Energy Technology Data Exchange (ETDEWEB)

    Lettry, J., E-mail: Jacques.lettry@cern.ch; Aguglia, D.; Andersson, P.; Bertolo, S.; Butterworth, A.; Coutron, Y.; Dallocchio, A.; David, N.; Chaudet, E.; Fink, D. A.; Garlasche, M.; Grudiev, A.; Guida, R.; Hansen, J.; Haase, M.; Jones, A.; Koszar, I.; Lallement, J.-B.; Lombardi, A. M.; Machado, C. [CERN-ABP, 1211 Geneva 23 (Switzerland); and others

    2016-02-15

    CERN’s 160 MeV H{sup −} linear accelerator (Linac4) is a key constituent of the injector chain upgrade of the Large Hadron Collider that is being installed and commissioned. A cesiated surface ion source prototype is being tested and has delivered a beam intensity of 45 mA within an emittance of 0.3 π ⋅ mm ⋅ mrad. The optimum ratio of the co-extracted electron- to ion-current is below 1 and the best production efficiency, defined as the ratio of the beam current to the 2 MHz RF-power transmitted to the plasma, reached 1.1 mA/kW. The H{sup −} source prototype and the first tests of the new ion source optics, electron-dump, and front end developed to minimize the beam emittance are presented. A temperature regulated magnetron H{sup −} source developed by the Brookhaven National Laboratory was built at CERN. The first tests of the magnetron operated at 0.8 Hz repetition rate are described.

  1. Development of hollow anode penning ion source for laboratory application

    Science.gov (United States)

    Das, B. K.; Shyam, A.; Das, R.; Rao, A. D. P.

    2012-03-01

    The research work presented here focuses for the development of miniature penning type ion source. One hollow anode penning type ion source was developed in our laboratory. The size of the ion source is 38 mm diameter and 55 mm length. The ion source consists of two cathodes, a hollow anode and one piece of rare earth permanent magnet. The plasma was created in the plasma region between cathodes and the hollow anode. The J × B force in the region helps for efficient ionization of the gas even in the high vacuum region˜1×10 -5 Torr. The ions were extracted in the axial direction with help of the potential difference between the electrodes and the geometry of the extraction angle. The effect of the extraction electrode geometry for efficient extraction of the ions from the plasma region was examined. This ion source is a self extracted ion source. The self extracted phenomena reduce the cost and the size of the ion source. The extracted ion current was measured by a graphite probe. An ion current of more than 200 μA was observed at the probe placed 70 mm apart from the extraction electrode. In this paper, the structure of the ion source, effect of operating pressure, potential difference and the magnetic field on the extracted ion current is reported.

  2. Langmuir probe studies on a RF ion source for NBI

    Energy Technology Data Exchange (ETDEWEB)

    McNeely, P. E-mail: p.mcneely@ipp.mpg.de; Heineman, B.; Kraus, W.; Riedl, R.; Speth, E.; Vollmer, O

    2001-10-01

    IPP Garching has been developing a RF ion source for H{sup -} production. In order to improve the data quality a new scanning probe system with passive RF compensation has been installed on the Type VI ion source on the BATMAN test stand. Using this probe, measurements have been carried out to study changes to the plasma parameters (electron density, electron temperature, and plasma potential) due to variation in the source operating conditions. The data were collected at a source pressure of 0.5 Pa and with 60{+-}5 kW applied RF power. Presented are some of the results of these measurements, focusing on the effect of: argon seeding, addition of Cs to the source, and the newly added Faraday screen. The electron density behaves in a fashion that agrees with the theory of ambipolar diffusion. Typically there is little change to the average electron energy observed regardless of which effect is considered. The plasma potential shows the most significant changes with external source conditions, both in value for all cases and shape when the Faraday screen was added.

  3. Progress of resonant ionization laser ion source development at GANIL

    Energy Technology Data Exchange (ETDEWEB)

    Henares, J. L., E-mail: henares@ganil.fr; Huguet, Y.; Lecesne, N.; Leroy, R.; Osmond, B.; Sjödin, A. M. [GANIL, BP 55027, 14076 Caen Cedex 5 (France); Kron, T.; Schneider, F.; Wendt, K. [Johannes Gutenberg-Universität Mainz, Staudinger Weg 7, 55099 Mainz (Germany)

    2014-02-15

    SPIRAL2 (Système de Production d’Ions Radioactifs Accélérés en Ligne) is a research facility under construction at GANIL (Grand Accélérateur National d’Ions Lourds) for the production of radioactive ion beams by isotope separation on-line methods and low-energy in-flight techniques. A resonant ionization laser ion source will be one of the main techniques to produce the radioactive ion beams. GISELE (GANIL Ion Source using Electron Laser Excitation) is a test bench developed to study a fully operational laser ion source available for Day 1 operations at SPIRAL2 Phase 2. The aim of this project is to find the best technical solution which combines high selectivity and ionization efficiency with small ion beam emittance and stable long term operation. Latest results about the new ion source geometry will be presented.

  4. Progress of resonant ionization laser ion source development at GANIL

    Science.gov (United States)

    Henares, J. L.; Huguet, Y.; Kron, T.; Lecesne, N.; Leroy, R.; Osmond, B.; Schneider, F.; Sjödin, A. M.; Wendt, K.

    2014-02-01

    SPIRAL2 (Système de Production d'Ions Radioactifs Accélérés en Ligne) is a research facility under construction at GANIL (Grand Accélérateur National d'Ions Lourds) for the production of radioactive ion beams by isotope separation on-line methods and low-energy in-flight techniques. A resonant ionization laser ion source will be one of the main techniques to produce the radioactive ion beams. GISELE (GANIL Ion Source using Electron Laser Excitation) is a test bench developed to study a fully operational laser ion source available for Day 1 operations at SPIRAL2 Phase 2. The aim of this project is to find the best technical solution which combines high selectivity and ionization efficiency with small ion beam emittance and stable long term operation. Latest results about the new ion source geometry will be presented.

  5. Use of ion sources for nonsemiconductor surface modification (plenary)

    Science.gov (United States)

    Iwaki, Masaya

    2002-02-01

    At RIKEN, studies have been made on surface modification of metals, ceramics, and polymers using ion implantation in order to improve surface properties of various materials. For fundamental studies of surface modification, about 60 kinds of ions have been used as implanted elements, using rf-type, Nielsen-type, and hollow cathode-type ion sources. The Nielsen-type ion source has been the most useful for obtaining various ion species by modification to the evaporation oven and by selection of the source material. High current beams of some kinds of ions were obtained using Freeman-type or microwave-type ion sources. Ion beam modification with nonmass analyzed ions was investigated for practicable use of ion implantation. In this article, these ion sources are described, and their utilization in a variety of applications is reviewed. The improvement of the lifetime of tools by nitrogen implantation is introduced as a topic in the fields of nonsemiconductor materials, and several points for expansion of the field are emphasized. As a successful example in Japan, the dynamic mixing used in industry is introduced and ion sources are shown to be one of the technologically important factors. Plasma based ion implantation is compared with traditional surface finishing. Finally, the fabrication of small vascular grafts controlling cell adhesion is introduced as the applications of ion beams to biomedical materials.

  6. ECR ion source based low energy ion beam facility

    Indian Academy of Sciences (India)

    Mass analyzed highly charged ion beams of energy ranging from a few keV to a few MeV plays an important role in various aspects of research in modern physics. In this paper a unique low energy ion beam facility (LEIBF) set up at Nuclear Science Centre (NSC) for providing low and medium energy multiply charged ion ...

  7. Low temperature synthesis of carbon-wrapped CuO synthesized without using a conventional carbon source for Li ion battery application

    Science.gov (United States)

    Saravanan, M.; Nair, Shantikumar V.; Rai, Alok Kumar

    2017-10-01

    Carbon-wrapped CuO is synthesized by a facile pyro-synthesis method without using a conventional carbon source to overcome the capacity fading issue of CuO nanoparticles. The microstructure analysis shows that the sample is fully wrapped by a carbon layer. The resultant carbon-wrapped CuO nanocomposite as an anode exhibits high reversible capacity with excellent cycling stability (437.1 mAh/g at 0.25 C and 365.2 mAh/g at 1.0 C after 100 cycles) and good rate capability. It is believed that the synergistic effect of CuO and carbon is responsible for the enhanced electrochemical performance of the nanocomposite electrode.

  8. Status report on electron cyclotron resonance ion sources at the Heavy Ion Medical Accelerator in Chiba

    CERN Document Server

    Kitagawa, A; Sekiguchi, M; Yamada, S; Jincho, K; Okada, T; Yamamoto, M; Hattori, T G; Biri, S; Baskaran, R; Sakata, T; Sawada, K; Uno, K

    2000-01-01

    The Heavy Ion Medical Accelerator in Chiba at the National Institute of Radiological Sciences (NIRS) is not only dedicated to cancer therapy, it is also utilized with various ion species for basic experiments of biomedical science, physics, chemistry, etc. Two electron cyclotron resonance (ECR) ion sources are installed for production of gaseous ions. One of them, the NIRS-ECR, is a 10 GHz ECR ion source, and is mainly operated to produce C/sup 4+/ ions for daily clinical treatment. This source realizes good reproducibility and reliability and it is easily operated. The other source, the NIRS-HEC, is an 18 GHz ECR ion source that is expected to produce heavier ion species. The output ion currents of the NIRS-ECR and the NIRS-HEC are 430e mu A for C/sup 4+/ and 1.1e mA for Ar/sup 8+/, respectively. (14 refs).

  9. Installation and operation of a high-temperature surface ion source for the online coupling of TRIGA-SPEC to the TRIGA Mainz research reactor and high-precision mass measurements of transuranium nuclides at TRIGA-TRAP

    Energy Technology Data Exchange (ETDEWEB)

    Renisch, Dennis

    2016-06-23

    The TRIGA-SPEC setup is dedicated for high-precision measurements of ground-state properties of exotic nuclides, like fission products or transuranium nuclides. For the online coupling of TRIGA-SPEC to the TRIGA Mainz research reactor, fission products are transported from a target chamber close to the reactor core by a gas-jet system to an ion source, which provides the connected experiments with a radioactive ion beam for the actual measurements. The design, installation and operation of the online ion source was a major part of the work described in this thesis. In addition, investigations on the optimal conditions of the gas-jet system for a reliable ion source operation were performed and the coupling of the ion source part to the subsequent elements of the beamline was conducted. The second part of this thesis deals with high-precision mass measurements on transuranium nuclides with the Penning-trap mass spectrometer TRIGA-TRAP, which is one branch of the TRIGA-SPEC setup. These measurements contribute to a mapping of the region of the chart of nuclides around the deformed shell closure at N=152. The masses of some of the investigated nuclides are directly measured for the first time. Due to the appearance of systematic inconsistencies during the evaluation of the mass measurements, the focus of the final section of this thesis lies in the identification and correction of the sources of the observed inconsistencies.

  10. Technological ion sources based on the vacuum arc discharge

    CERN Document Server

    Bugaev, S P; Oks, E M; Yushkov, G Y; Shchanin, P M; Braun, Y

    2001-01-01

    The Titan service ion sources are designed to generate wide-aperture high-current ion beams of gases or metals, as well as, mixed two-component gas and metal ion beams with the controllable ratio of components in a beam. This possibility is achieved via integration of two discharge systems in a source discharge system. To generate metal ions one uses a vacuum, arc discharge, while gas ions are generated by a low pressure contracted arc discharge with cold cathodes. The paper describes operation of these sources, their design, technical characteristics, peculiarities of their operation and application fields

  11. Application of compact electron cyclotron resonance ion source

    NARCIS (Netherlands)

    Muramatsu, M.; Kitagawa, A.; Iwata, Y.; Ogawa, H.; Hojo, S.; Kubo, T.; Kato, Y.; Biri, S.; Fekete, E.; Yoshida, Y.; Drentje, A. G.

    The compact electron cyclotron resonance (ECR) ion source with a permanent magnet configuration (Kei2 source) has been developed at National Institute of Radiological Sciences for a new carbon therapy facility. The Kei2 source was designed for production of C(4+) ions; its performance such as beam

  12. Damping of toroidal ion temperature gradient modes

    Energy Technology Data Exchange (ETDEWEB)

    Sugama, H. [National Inst. for Fusion Science, Toki, Gifu (Japan)

    1999-04-01

    The temporal evolution of linear toroidal ion temperature gradient (ITG) modes is studied based on a kinetic integral equation including an initial condition. It is shown how to evaluate the analytic continuation of the integral kernel as a function of a complex-valued frequency, which is useful for analytical and numerical calculations of the asymptotic damping behavior of the ITG mode. In the presence of the toroidal {nabla}B-curvature drift, the temporal dependence of the density and potential perturbations consists of normal modes and a continuum mode, which correspond to contributions from poles and from an integral along a branch cut, respectively, of the Laplace-transformed potential function of the complex-valued frequency. The normal modes have exponential time dependence with frequencies and growth rates determined by the dispersion relation while the continuum mode, which has a ballooning structure, shows a power law decay {proportional_to} t{sup -2} in the asymptotic limit, where t is the time variable. Therefore, the continuum mode dominantly describes the long-time asymptotic behavior of the density and potential perturbations for the stable system where all normal modes have negative growth rates. By performing proper analytic continuation for the homogeneous version of the kinetic integral equation, dependences of the normal modes` growth rate, real frequency, and eigenfunction on {eta}{sub i} (the ratio of the ion temperature gradient to the density gradient), k{sub {theta}} (the poloidal wavenumber), s (the magnetic shear parameter), and {theta}{sub k} (the ballooning angle corresponding to the minimum radial wavenumber) are numerically obtained for both stable and unstable cases. (author)

  13. Plasmas in compact traps: From ion sources to multidisciplinary research

    Science.gov (United States)

    Mascali, D.; Musumarra, A.; Leone, F.; Galatà, A.; Romano, F. P.; Gammino, S.

    2017-09-01

    In linear (minimum-B) magneto-static traps dense and hot plasmas are heated by electromagnetic radiation in the GHz domain via the Electron Cyclotron Resonance (ECR). The values of plasma density, temperature and confinement times ( n_eτ_i>10^{13} cm ^{-3} s; T_e>10 keV) are similar to the ones of thermonuclear plasmas. The research in this field -devoted to heating and confinement optimization- has been supported by numerical modeling and advanced diagnostics, for probing the plasma especially in a non-invasive way. ECR-based systems are nowadays able to produce extremely intense (tens or hundreds of mA) beams of light ions (p, d, He), and relevant currents of heavier elements (C, O, N) up to heavy ions like Xe, Pb, U. Such beams can be extracted from the trap by a proper electrostatic system. The above-mentioned properties make these plasmas very attractive for interdisciplinary researches also, such as i) nuclear decays rates measurements in stellar-like conditions, ii) energy conversion studies, being exceptional sources of short-wavelength electromagnetic radiation (EUV, X-rays, hard X-rays and gammas, useful in material science and archaeometry), iii) environments allowing precise spectroscopical measurements as benchmarks for magnetized astrophysical plasmas. The talk will give an overview about the state-of-the-art in the field of intense ion sources, and some new perspectives for interdisciplinary research, with a special attention to the developments based at INFN-LNS.

  14. Proton and Ion Sources for High Intensity Accelerators

    CERN Multimedia

    Scrivens, R

    2004-01-01

    Future high intensity ion accelerators, including the Spallation Neutron Source (SNS), the European Spallation Source (ESS), the Superconducting Proton Linac (SPL) etc, will require high current and high duty factor sources for protons and negative hydrogen ions. In order to achieve these goals, a comparison of the Electron Cyclotron Resonance, radio-frequency and Penning ion sources, among others, will be made. For each of these source types, the present operational sources will be compared to the state-of-the-art research devices with special attention given to reliability and availability. Finally, the future research and development aims will be discussed.

  15. High Intensity High Charge State ECR Ion Sources

    CERN Document Server

    Leitner, Daniela

    2005-01-01

    The next-generation heavy ion beam accelerators such as the proposed Rare Isotope Accelerator (RIA), the Radioactive Ion Beam Factory at RIKEN, the GSI upgrade project, the LHC-upgrade, and IMP in Lanzhou require a great variety of high charge state ion beams with a magnitude higher beam intensity than currently achievable. High performance Electron Cyclotron Resonance (ECR) ion sources can provide the flexibility since they can routinely produce beams from hydrogen to uranium. Over the last three decades, ECR ion sources have continued improving the available ion beam intensities by increasing the magnetic fields and ECR heating frequencies to enhance the confinement and the plasma density. With advances in superconducting magnet technology, a new generation of high field superconducting sources is now emerging, designed to meet the requirements of these next generation accelerator projects. The talk will briefly review the field of high performance ECR ion sources and the latest developments for high intens...

  16. Intrinsic parallel rotation drive by electromagnetic ion temperature gradient turbulence

    CERN Document Server

    Peng, Shuitao; Pan, Yuan

    2016-01-01

    The quasilinear intrinsic parallel flow drive including parallel residual stress, kinetic stress, cross Maxwell stress and parallel turbulent acceleration by electromagnetic ion temperature gradient (ITG) turbulence is calculated analytically using electromagnetic gyrokinetic theory. Both the kinetic stress and cross Maxwell stress also enter the mean parallel flow velocity equation via their divergence, as for the usual residual stress. The turbulent acceleration driven by ion pressure gradient along the total magnetic field (including equilibrium magnetic field and fluctuating radial magnetic field) cannot be written as a divergence of stress, and so should be treated as a local source/sink. All these terms can provide intrinsic parallel rotation drive. Electromagnetic effects reduce the non-resonant electrostatic stress force and even reverse it, but enhance the resonant stress force. Both the non-resonant and resonant turbulent acceleration terms are also enhanced by electromagnetic effects. The possible ...

  17. Three-dimensional simulations of ion dynamics in the plasma of an electron cyclotron resonance ion source

    Directory of Open Access Journals (Sweden)

    V. Mironov

    2009-07-01

    Full Text Available The ion production in an electron cyclotron resonance ion source (ECRIS is modeled using a particle-in-cell Monte-Carlo-collision code in a three-dimensional geometry. Only the heavy particles (ions and atoms are tracked, while the electrons are represented using a Maxwell-Boltzmann energy distribution with the electron density determined from the requirement of quasineutrality, and the electron temperature considered as a free parameter. It is found that experimentally observed features of ECRIS plasma are closely reproduced by the code, including the charge-state distributions of extracted ion beams and sputtering patterns inside the source. The isotope anomaly is observed for the mixture of ^{20}Ne+^{22}Ne isotopes, and a possible explanation is proposed. Finally, the wall-coating effect is treated by modeling the neutralization of ions impinging on the walls of the plasma chamber.

  18. Xenon gas field ion source from a single-atom tip

    Science.gov (United States)

    Lai, Wei-Chiao; Lin, Chun-Yueh; Chang, Wei-Tse; Li, Po-Chang; Fu, Tsu-Yi; Chang, Chia-Seng; Tsong, T. T.; Hwang, Ing-Shouh

    2017-06-01

    Focused ion beam (FIB) systems have become powerful diagnostic and modification tools for nanoscience and nanotechnology. Gas field ion sources (GFISs) built from atomic-size emitters offer the highest brightness among all ion sources and thus can improve the spatial resolution of FIB systems. Here we show that the Ir/W(111) single-atom tip (SAT) can emit high-brightness Xe+ ion beams with a high current stability. The ion emission current versus extraction voltage was analyzed from 150 K up to 309 K. The optimal emitter temperature for maximum Xe+ ion emission was ˜150 K and the reduced brightness at the Xe gas pressure of 1 × 10-4 torr is two to three orders of magnitude higher than that of a Ga liquid metal ion source, and four to five orders of magnitude higher than that of a Xe inductively coupled plasma ion source. Most surprisingly, the SAT emitter remained stable even when operated at 309 K. Even though the ion current decreased with increasing temperature, the current at room temperature (RT) could still reach over 1 pA when the gas pressure was higher than 1 × 10-3 torr, indicating the feasibility of RT-Xe-GFIS for application to FIB systems. The operation temperature of Xe-SAT-GFIS is considerably higher than the cryogenic temperature required for the helium ion microscope (HIM), which offers great technical advantages because only simple or no cooling schemes can be adopted. Thus, Xe-GFIS-FIB would be easy to implement and may become a powerful tool for nanoscale milling and secondary ion mass spectroscopy.

  19. Implementation of Design Changes Towards a More Reliable, Hands-off Magnetron Ion Source

    Energy Technology Data Exchange (ETDEWEB)

    Sosa, A. [Fermilab; Bollinger, D. S. [Fermilab; Karns, P. R. [Fermilab; Tan, C. Y. [Fermilab

    2017-12-07

    As the main H- ion source for the accelerator complex, magnetron ion sources have been used at Fermilab since the 1970’s. At the offline test stand, new R&D is carried out to develop and upgrade the present magnetron-type sources of H- ions of up to 80 mA and 35 keV beam energy in the context of the Proton Improvement Plan. The aim of this plan is to provide high-power proton beams for the experiments at FNAL. In order to reduce the amount of tuning and monitoring of these ion sources, a new electronic system consisting of a current-regulated arc discharge modulator allow the ion source to run at a constant arc current for improved beam output and operation. A solenoid-type gas valve feeds H2 gas into the source precisely and independently of ambient temperature. This summary will cover several studies and design changes that have been tested and will eventually be implemented on the operational magnetron sources at Fermilab. Innovative results for this type of ion source include cathode geometries, solenoid gas valves, current controlled arc pulser, cesium boiler redesign, gas mixtures of hydrogen and nitrogen, and duty factor reduction, with the aim to improve source lifetime, stability, and reducing the amount of tuning needed. In this summary, I will highlight the advances made in ion sources at Fermilab and will outline the directions of the continuing R&D effort.

  20. Neutron scattering effects on fusion ion temperature measurements.

    Energy Technology Data Exchange (ETDEWEB)

    Ziegler, Lee (Bechtel/Nevada, Las Vegas, NV); Starner, Jason R.; Cooper, Gary Wayne; Ruiz, Carlos L.; Franklin, James Kenneth (Ktech Corporation, Albuquerque, NM); Casey, Daniel T.

    2006-06-01

    To support the nuclear fusion program at Sandia National Laboratories (SNL), a consistent and verifiable method to determine fusion ion temperatures needs to be developed. Since the fusion temperature directly affects the width in the spread of neutron energies produced, a measurement of the neutron energy width can yield the fusion temperature. Traditionally, the spread in neutron energies is measured by using time-of-flight to convert a spread in neutron energies at the source to a spread in time at detector. One potential obstacle to using this technique at the Z facility at SNL is the need to shield the neutron detectors from the intense bremsstrahlung produced. The shielding consists of eight inches of lead and the concern is that neutrons will scatter in the lead, artificially broaden the neutron pulse width and lead to an erroneous measurement. To address this issue, experiments were performed at the University of Rochester's Laboratory for Laser Energetics, which demonstrated that a reliable ion temperature measurement can be achieved behind eight inches of lead shielding. To further expand upon this finding, Monte Carlo N-Particle eXtended (MCNPX) was used to simulate the experimental geometric conditions and perform the neutron transport. MCNPX was able to confidently estimate results observed at the University of Rochester.

  1. Ion Source Physics and Technology (1/2)

    CERN Multimedia

    CERN. Geneva

    2016-01-01

    This series of lectures starts with an introduction in some aspects of atomic and plasma physics as base for the ion source physics. The main part covers aspects of ion source physics, technology and operation. Several source types are presented. Some information on infrastructure and supporting services (as high voltage, cooling, microwaves etc) are given to better understand the source environment. The last part on engineering aims to show that, in the field of ion sources, many different technologies are combined in a quite small environment, which is challenging and interesting at the same time.

  2. Ion Source Physics and Technology (2/2)

    CERN Multimedia

    CERN. Geneva

    2016-01-01

    This series of lectures starts with an introduction in some aspects of atomic and plasma physics as base for the ion source physics. The main part covers aspects of ion source physics, technology and operation. Several source types are presented. Some information on infrastructure and supporting services (as high voltage, cooling, microwaves etc) are given to better understand the source environment. The last part on engineering aims to show that, in the field of ion sources, many different technologies are combined in a quite small environment, which is challenging and interesting at the same time.

  3. Electron energy recovery system for negative ion sources

    Science.gov (United States)

    Dagenhart, W.K.; Stirling, W.L.

    1979-10-25

    An electron energy recovery system for negative ion sources is provided. The system, employing crossed electric and magnetic fields, separates the electrons from the ions as they are extracted from the ion source plasma generator and before the ions are accelerated to their full energy. With the electric and magnetic fields oriented 90/sup 0/ to each other, the electrons remain at approximately the electrical potential at which they were generated. The electromagnetic forces cause the ions to be accelerated to the full accelerating supply voltage energy while being deflected through an angle of less than 90/sup 0/. The electrons precess out of the accelerating field region into an electron recovery region where they are collected at a small fraction of the full accelerating supply energy. It is possible, by this method, to collect > 90% of the electrons extracted along with the negative ions from a negative ion source beam at energy.

  4. Verification of high efficient broad beam cold cathode ion source

    Energy Technology Data Exchange (ETDEWEB)

    Abdel Reheem, A. M., E-mail: amreheem2009@yahoo.com [Accelerators and Ion Sources Department, Nuclear Research Center, Atomic Energy Authority, P.N.13759, Cairo (Egypt); Radiation Physics Department, National Center for Radiation Research and Technology (NCRRT), Atomic Energy Authority (AEA), Cairo (Egypt); Ahmed, M. M. [Physics Department, Faculty of Science, Helwan University, Cairo (Egypt); Abdelhamid, M. M.; Ashour, A. H. [Radiation Physics Department, National Center for Radiation Research and Technology (NCRRT), Atomic Energy Authority (AEA), Cairo (Egypt)

    2016-08-15

    An improved form of cold cathode ion source has been designed and constructed. It consists of stainless steel hollow cylinder anode and stainless steel cathode disc, which are separated by a Teflon flange. The electrical discharge and output characteristics have been measured at different pressures using argon, nitrogen, and oxygen gases. The ion exit aperture shape and optimum distance between ion collector plate and cathode disc are studied. The stable discharge current and maximum output ion beam current have been obtained using grid exit aperture. It was found that the optimum distance between ion collector plate and ion exit aperture is equal to 6.25 cm. The cold cathode ion source is used to deposit aluminum coating layer on AZ31 magnesium alloy using argon ion beam current which equals 600 μA. Scanning electron microscope and X-ray diffraction techniques used for characterizing samples before and after aluminum deposition.

  5. 6.4 GHz ECR ion source at VECC

    Indian Academy of Sciences (India)

    The 6.4 GHz ECR ion source that was indigenously developed a few years ago has been operating continuously for injecting oxygen and neon beams to the cyclotron since 1997. VEC-ECR is a single stage high magnetic field ion source provided with a negatively biased electron repeller placed on the axis, near the ...

  6. Characteristics of the KVI electron cyclotron resonance ion source

    NARCIS (Netherlands)

    Kremers, HR; Beijers, JPM; Brandenburg, S

    In this article, an update will be given of last year's activities to modify the CAPRICE-type ECR ion source into an AECR-type ECR ion source as developed in Berkely, Argonne and Jyvaskyla. Here we will present measurements on the radial and the axial magnetic field, the vacuum system, report on the

  7. Compact ECR ion source with permanent magnets for Carbon therapy

    NARCIS (Netherlands)

    Muramatsu, M; Kitagawa, A; Sakamoto, Y; Sato, Y; Yamada, S; Ogawa, H; Drentje, AG; Biri, S; Yoshida, Y

    Ion sources for the medical facilities should have the following characteristics of easy maintenance, low electric power, good stability, and long operation time without trouble (1 year or longer). For this, a 10 GHz compact electron cyclotron resonance ion source (ECRIS) with all permanent magnets

  8. Experimental system of ejected electron spectroscopy with ECR ion source

    Energy Technology Data Exchange (ETDEWEB)

    Kitazawa, Sin-iti [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1995-09-01

    The experiment of analyzing energy spectrum of electrons ejected from multiple electron capture process on ion-atom collision is carried out using ECR (Electron Cyclotron Resonance) ion source. An old collision system using gas atoms as target and a new system using vapour atoms are developed. In this report, the developments and exploitations of the experimental systems for the ejected electron spectroscopy with ECR Ion source are presented. (author).

  9. Negative ions as a source of low energy neutral beams

    Energy Technology Data Exchange (ETDEWEB)

    Fink, J.H.

    1980-01-01

    Little consideration has been given to the impact of recent developments in negative ion source technology on the design of low energy neutral beam injectors. However, negative ion sources of improved operating efficiency, higher gas efficiency, and smaller beam divergence will lead to neutral deuterium injectors, operating at less than 100 keV, with better operating efficiencies and more compact layouts than can be obtained from positive ion systems.

  10. Volume and Surface-Enhanced Volume Negative Ion Sources

    CERN Document Server

    Stockli, M.P.

    2013-12-16

    H- volume sources and, especially, caesiated H- volume sources are important ion sources for generating high-intensity proton beams, which then in turn generate large quantities of other particles. This chapter discusses the physics and technology of the volume production and the caesium-enhanced (surface) production of H- ions. Starting with Bacal's discovery of the H- volume production, the chapter briefly recounts the development of some H- sources, which capitalized on this process to significantly increase the production of H- beams. Another significant increase was achieved in the 1990s by adding caesiated surfaces to supplement the volume-produced ions with surface-produced ions, as illustrated with other H- sources. Finally, the focus turns to some of the experience gained when such a source was successfully ramped up in H- output and in duty factor to support the generation of 1 MW proton beams for the Spallation Neutron Source.

  11. A study on the design of hexapole in an 18-GHz ECR ion source for heavy ion accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Zhan; Wei, Shaoqing; Lee, Sang Jin [Uiduk University, Gyeongju (Korea, Republic of); Choi, Suk Jin [Rare Isotope Science Project, Institute for Basic Science, Daejeon (Korea, Republic of)

    2016-06-15

    High charge state electron cyclotron resonance (ECR) ion source is important on the performance of heavy ion accelerators. In this paper, a low temperature superconductor (LTS) was used to make a hexapole coil for an 18-GHz ECR ion source. Several hexapole structures, including racetrack, graded racetrack, and saddle were implemented and analyzed for the hexapole-in-solenoid ECR ion source system. Under the appropriate radial confinement field, the smaller outer radius of hexapole can be better for the solenoid design. Saddle hexapole was selected by comparing the wire length, maximum outer radius of the hexapole, the Lorentz force at the end part of the hexapole and the maximum magnetic field in the coil. Based on saddle hexapole, a new design for hexapoles, the snake hexapole, was developed in this paper. By comparative analysis of the Lorentz force at the end part of the saddle and snake hexapoles, the snake hexapole is much better in the ECR ion source system. The suggested design for the ECR ion source with the snake hexapole is presented in this paper.

  12. Liquid metal ion source and alloy for ion emission of multiple ionic species

    Science.gov (United States)

    Clark, Jr., William M.; Utlaut, Mark W.; Wysocki, Joseph A.; Storms, Edmund K.; Szklarz, Eugene G.; Behrens, Robert G.; Swanson, Lynwood W.; Bell, Anthony E.

    1987-06-02

    A liquid metal ion source and alloy for the simultaneous ion evaporation of arsenic and boron, arsenic and phosphorus, or arsenic, boron and phosphorus. The ionic species to be evaporated are contained in palladium-arsenic-boron and palladium-arsenic-boron-phosphorus alloys. The ion source, including an emitter means such as a needle emitter and a source means such as U-shaped heater element, is preferably constructed of rhenium and tungsten, both of which are readily fabricated. The ion sources emit continuous beams of ions having sufficiently high currents of the desired species to be useful in ion implantation of semiconductor wafers for preparing integrated circuit devices. The sources are stable in operation, experience little corrosion during operation, and have long operating lifetimes.

  13. Numerical model of electron cyclotron resonance ion source

    Directory of Open Access Journals (Sweden)

    V. Mironov

    2015-12-01

    Full Text Available Important features of the electron cyclotron resonance ion source (ECRIS operation are accurately reproduced with a numerical code. The code uses the particle-in-cell technique to model the dynamics of ions in ECRIS plasma. It is shown that a gas dynamical ion confinement mechanism is sufficient to provide the ion production rates in ECRIS close to the experimentally observed values. Extracted ion currents are calculated and compared to the experiment for a few sources. Changes in the simulated extracted ion currents are obtained with varying the gas flow into the source chamber and the microwave power. Empirical scaling laws for ECRIS design are studied and the underlying physical effects are discussed.

  14. Production of low axial energy spread ion beams with multicusp sources

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Yung -Hee Y. [Univ. of California, Berkeley, CA (United States)

    1998-05-01

    Multicusp ion sources are capable of producing ions with low axial energy spread which are necessary in applications such as: ion projection lithography (IPL) and focused ion beams for the next generation lithographic tools and nuclear science experiments such as radioactive ion beam production. The axial ion energy spread for multicusp source is approximately 6 eV which is too large for IPL and radioactive ion beam applications. The addition of a magnetic filter which consists of a pair of permanent magnets to the multicusp source reduces the energy spread considerably. The reduction is due to the improvement in the uniformity of the axial plasma potential distribution in the discharge region. Axial ion energy spread of the filament driven ion source has been measured using three different techniques. In all cases, it was found to be less than 2 eV. Energy spread of the radio frequency (RF) driven source has also been explored, and it was found to be less than 3 eV with the proper RF-shielding. A new multicusp source configuration has been designed and constructed to further reduce the energy spread. To achieve a more uniform axial plasma potential distribution, a cylindrical magnetic filter has been designed and constructed for a 2-cm-diameter source. This new source configuration, the co-axial source, is new in its kind. The energy spread in this source has been measured to be a record low of 0.6 eV. Because of the novelty of this device, some plasma parameters inside the source have been studied. Langmuir probe has been used to measure the plasma potential, the electron temperature and the density distribution.

  15. Isotopic anomaly for carbon ions in an electron cyclotron resonance ion source

    NARCIS (Netherlands)

    Drentje, A. G.; Kitagawa, A.; Muramatsu, M.

    In many experiments methods were applied to increase the highly charged ion output from an electron cyclotron resonance ion source; the gas-mixing method is still generally being applied. The dominant role of the masses of the ions in the gas-mixture was apparent. Two basically differing mechanisms

  16. Physical mechanisms leading to high currents of highly charged ions in laser-driven ion sources

    Energy Technology Data Exchange (ETDEWEB)

    Haseroth, Helmut [European Organization for Nuclear Research, Geneva (Switzerland); Hora, Heinrich [New South Wales Univ., Kensington, NSW (Australia)]|[Regensburg Inst. of Tech. (Germany). Anwenderzentrum

    1996-12-31

    Heavy ion sources for the big accelerators, for example, the LHC, require considerably more ions per pulse during a short time than the best developed classical ion source, the electron cyclotron resonance (ECR) provides; thus an alternative ion source is needed. This can be expected from laser-produced plasmas, where dramatically new types of ion generation have been observed. Experiments with rather modest lasers have confirmed operation with one million pulses of 1 Hz, and 10{sup 11} C{sup 4+} ions per pulse reached 2 GeV/u in the Dubna synchrotron. We review here the complexities of laser-plasma interactions to underline the unique and extraordinary possibilities that the laser ion source offers. The complexities are elaborated with respect to keV and MeV ion generation, nonlinear (ponderomotive) forces, self-focusing, resonances and ``hot`` electrons, parametric instabilities, double-layer effects, and the few ps stochastic pulsation (stuttering). Recent experiments with the laser ion source have been analyzed to distinguish between the ps and ns interaction, and it was discovered that one mechanism of highly charged ion generation is the electron impact ionization (EII) mechanism, similar to the ECR, but with so much higher plasma densities that the required very large number of ions per pulse are produced. (author).

  17. Numerical simulations of gas mixing effect in electron cyclotron resonance ion sources

    Directory of Open Access Journals (Sweden)

    V. Mironov

    2017-01-01

    Full Text Available The particle-in-cell Monte Carlo collisions code nam-ecris is used to simulate the electron cyclotron resonance ion source (ECRIS plasma sustained in a mixture of Kr with O_{2}, N_{2}, Ar, Ne, and He. The model assumes that ions are electrostatically confined in the ECR zone by a dip in the plasma potential. A gain in the extracted krypton ion currents is seen for the highest charge states; the gain is maximized when oxygen is used as a mixing gas. The special feature of oxygen is that most of the singly charged oxygen ions are produced after the dissociative ionization of oxygen molecules with a large kinetic energy release of around 5 eV per ion. The increased loss rate of energetic lowly charged ions of the mixing element requires a building up of the retarding potential barrier close to the ECR surface to equilibrate electron and ion losses out of the plasma. In the mixed plasmas, the barrier value is large (∼1  V compared to pure Kr plasma (∼0.01  V, with longer confinement times of krypton ions and with much higher ion temperatures. The temperature of the krypton ions is increased because of extra heating by the energetic oxygen ions and a longer time of ion confinement. In calculations, a drop of the highly charged ion currents of lighter elements is observed when adding small fluxes of krypton into the source. This drop is caused by the accumulation of the krypton ions inside plasma, which decreases the electron and ion confinement times.

  18. Oxygen ion source and RFQ for Linac 1

    CERN Multimedia

    Photographic Service

    1986-01-01

    As injector to the PS Booster, Linac 1 was replaced by Linac 2 in 1980. It continued to be used for the acceleration of oxygen and sulfur ions. In 1984, its Cockcroft-Walton preinjector was replaced by an RFQ. In the foreground at the right is the oxygen ion source. A 90 deg bending magnet selects O6+ ions which are preaccelerated in an RFQ and enter Linac 1, at the far left. In the background is the proton and negative hydrogen ion source, followed by the 520 keV RFQ-1 and a bending magnet towards the entrance of Linac 1.

  19. An ion trap-ion mobility-time of flight mass spectrometer with three ion sources for ion/ion reactions.

    Science.gov (United States)

    Zhao, Qin; Soyk, Matthew W; Schieffer, Gregg M; Fuhrer, Katrin; Gonin, Marc M; Houk, R S; Badman, Ethan R

    2009-08-01

    This instrument combines the capabilities of ion/ion reactions with ion mobility (IM) and time-of-flight (TOF) measurements for conformation studies and top-down analysis of large biomolecules. Ubiquitin ions from either of two electrospray ionization (ESI) sources are stored in a three dimensional (3D) ion trap (IT) and reacted with negative ions from atmospheric sampling glow discharge ionization (ASGDI). The proton transfer reaction products are then separated by IM and analyzed via a TOF mass analyzer. In this way, ubiquitin +7 ions are converted to lower charge states down to +1; the ions in lower charge states tend to be in compact conformations with cross sections down to approximately 880 A(2). The duration and magnitude of the ion ejection pulse on the IT exit and the entrance voltage on the IM drift tube can affect the measured distribution of conformers for ubiquitin +7 and +6. Alternatively, protein ions are fragmented by collision-induced dissociation (CID) in the IT, followed by ion/ion reactions to reduce the charge states of the CID product ions, thus simplifying assignment of charge states and fragments using the mobility-resolved tandem mass spectrum. Instrument characteristics and the use of a new ion trap controller and software modifications to control the entire instrument are described.

  20. Preliminary Tests of a Paul ion Trap as an Ion Source

    Science.gov (United States)

    Sadat Kiai, S. M.; Zirak, A. R.; Elahi, M.; Adlparvar, S.; Mortazavi, B. N.; Safarien, A.; Farhangi, S.; Sheibani, S.; Alhooie, S.; Khalaj, M. M. A.; Dabirzadeh, A. A.; Ruzbehani, M.; Zahedi, F.

    2010-10-01

    The paper reports on the design and construction of a Paul ion trap as an ion source by using an impact electron ionization technique. Ions are produced in the trap and confined for the specific time which is then extracted and detected by a Faraday cup. Especial electronic configurations are employed between the end caps, ring electrodes, electron gun and a negative voltage for the detector. This configuration allows a constant low level of pure ion source between the pulsed confined ion sources. The present experimental results are based on the production and confinement of Argon ions with good stability and repeatability, but in principle, the technique can be used for various Argon like ions.

  1. Ion source and injection line for high intensity medical cyclotron.

    Science.gov (United States)

    Jia, XianLu; Guan, Fengping; Yao, Hongjuan; Zhang, TianJue; Yang, Jianjun; Song, Guofang; Ge, Tao; Qin, Jiuchang

    2014-02-01

    A 14 MeV high intensity compact cyclotron, CYCIAE-14, was built at China Institute of Atomic Energy (CIAE). An injection system based on the external H- ion source was used on CYCIAE-14 so as to provide high intensity beam, while most positron emission tomography cyclotrons adopt internal ion source. A beam intensity of 100 μA/14 MeV was extracted from the cyclotron with a small multi-cusp H- ion source (CIAE-CH-I type) and a short injection line, which the H- ion source of 3 mA/25 keV H- beam with emittance of 0.3π mm mrad and the injection line of with only 1.2 m from the extraction of ion source to the medial plane of the cyclotron. To increase the extracted beam intensity of the cyclotron, a new ion source (CIAE-CH-II type) of 9.1 mA was used, with maximum of 500 μA was achieved from the cyclotron. The design and test results of the ion source and injection line optimized for high intensity acceleration will be given in this paper.

  2. An ion guide laser ion source for isobar-suppressed rare isotope beams

    Energy Technology Data Exchange (ETDEWEB)

    Raeder, Sebastian, E-mail: sebastian.raeder@fys.kuleuven.be; Ames, Friedhelm; Bishop, Daryl; Bricault, Pierre; Kunz, Peter; Mjøs, Anders [TRIUMF, 4004 Wesbrook Mall, Vancouver, British Columbia V6T 2A3 (Canada); Heggen, Henning, E-mail: heggen@triumf.ca [TRIUMF, 4004 Wesbrook Mall, Vancouver, British Columbia V6T 2A3 (Canada); Institute of Applied Physics, TU Darmstadt, Schlossgartenstr. 7, 64289 Darmstadt (Germany); Lassen, Jens, E-mail: lassen@triumf.ca; Teigelhöfer, Andrea [TRIUMF, 4004 Wesbrook Mall, Vancouver, British Columbia V6T 2A3 (Canada); Department of Physics and Astronomy, University of Manitoba, Winnipeg, Manitoba R3T 2N2 (Canada)

    2014-03-15

    Modern experiments at isotope separator on-line (ISOL) facilities like ISAC at TRIUMF often depend critically on the purity of the delivered rare isotope beams. Therefore, highly selective ion sources are essential. This article presents the development and successful on-line operation of an ion guide laser ion source (IG-LIS) for the production of ion beams free of isobaric contamination. Thermionic ions from the hot ISOL target are suppressed by an electrostatic potential barrier, while neutral radio nuclides effusing out are resonantly ionized by laser radiation within a quadrupole ion guide behind this barrier. The IG-LIS was developed through detailed thermal and ion optics simulation studies and off-line tests with stable isotopes. In a first on-line run with a SiC target a suppression of surface-ionized Na contaminants in the ion beam of up to six orders of magnitude was demonstrated.

  3. Recent Developments for ECR Ion Sources at HIMAC

    CERN Document Server

    Kitagawa, A; Sekiguchi, M; Yamada, S; Okada, T; Yamamoto, M; Biri, S; Uno, K

    1999-01-01

    Two ECR ion sources are installed for the Heavy Ion Medical Accelerator in Chiba (HIMAC) at the National Institute of Radiological Sciences (NIRS). One of them, the NIRS-ECR, is a 10GHz ECR ion source, and is mainly operated to produce C4+ ions for the daily clinical treatment. The other source, the NIRS-HEC, is an 18GHz ECR ion source, and is expected to produce heavier ion species. In order to realize the uniform ion-density distribution at the extraction aperture for the higher beam intensity, the radial magnetic field given by the permanent sextupole magnet has been optimized. In the case of the optimized magnetic configuration of the NIRS-HEC, the extracted intensities of Ar8+ and Ar9+ ions increased from 250 and 150 up to 800 and 400 electric micro A, respectively. An optimized sextupole magnet for the NIRS-ECR is under construction. Other developments for increasing the beam intensity and extension of producible ion species are now in progress. An aluminum chamber, which is exchanged for the old copper...

  4. Switching regulator emission control circuit for ion sources

    Science.gov (United States)

    Clay, F. P., Jr.; Brock, F. J.; Melfi, L. T., Jr.

    1975-01-01

    An electron emission control circuit of the switching regulator type operating at 100 kHz has been developed which maintains a constant emission current within 0.1% for a cathode power demand variation of approximately 100%. The power output stage has an efficiency of 67%, and the overall efficiency is 45% when driving a thoria-coated iridium cathode having a nominal resistance at operating temperature of 2.5 ohms. Under optimum conditions, the bus power demand is 1.75 W. The circuit is useful in controlling the electron emission current of ion sources in applications which involve a substantial variation of the cathode work function, such as oxygen partial pressure measurements over a large dynamic range.

  5. Ion current detector for high pressure ion sources for monitoring separations

    Energy Technology Data Exchange (ETDEWEB)

    Smith, R.D.; Wahl, J.H.; Hofstadler, S.A.

    1996-08-13

    The present invention relates generally to any application involving the monitoring of signal arising from ions produced by electrospray or other high pressure (>100 torr) ion sources. The present invention relates specifically to an apparatus and method for the detection of ions emitted from a capillary electrophoresis (CE) system, liquid chromatography, or other small-scale separation methods. And further, the invention provides a very simple diagnostic as to the quality of the separation and the operation of an electrospray source. 7 figs.

  6. Ion current detector for high pressure ion sources for monitoring separations

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Richard D. (Richland, WA); Wahl, Jon H. (Richland, WA); Hofstadler, Steven A. (Richland, WA)

    1996-01-01

    The present invention relates generally to any application involving the monitoring of signal arising from ions produced by electrospray or other high pressure (>100 torr) ion sources. The present invention relates specifically to an apparatus and method for the detection of ions emitted from a capillary electrophoresis (CE) system, liquid chromatography, or other small-scale separation methods. And further, the invention provides a very simple diagnostic as to the quality of the separation and the operation of an electrospray source.

  7. Characterisation and Performance of The CERN ECR4 Ion Source

    CERN Document Server

    Hill, C E; Chamings, J A; Coco, V; Küchler, D; Lombardi, A M; Sargsya, E; Scrivens, R; ECRIS'04

    2005-01-01

    To optimise the heavy ion injector for the LHC, a good knowledge of the parameters of the ECR4 ion source and the beam transport in the Low Energy Beam Transport (LEBT) for a lead ion beam is necessary. Results of the emittance measurements of the full beam (O + Pb) leaving the source using a scanning slit and profile monitor will be presented. Furthermore, the emittance of a single charge state after the source has been measured using a solenoid scan coupled to a guillotine and spectrometer. The results for last year’s operation for the SPS fixed target physics with indium will also be presented.

  8. Metallic glass as a temperature sensor during ion plating

    Science.gov (United States)

    Miyoshi, K.; Spalvins, T.; Buckley, D. H.

    1985-01-01

    The temperature of the interface and/or a superficial layer of a substrate during ion plating was investigated using a metallic glass of the composition Fe67Co18B14Si1 as the substrate and as the temperature sensor. Transmission electron microscopy and diffraction studies determined the microstructure of the ion-plated gold film and the substrate. Results indicate that crystallization occurs not only in the film, but also in the substrate. The grain size of crystals formed during ion plating was 6 to 60 nm in the gold film and 8 to 100 nm in the substrate at a depth of 10 to 15 micrometers from the ion-plated interface. The temperature rise of the substrate during ion plating was approximately 500 C. Discontinuous changes in metallurgical microstructure, and physical, chemical, and mechanical properties during the amorphous to crystalline transition in metallic glasses make metallic glasses extremely useful materials for temperature sensor applications in coating processes.

  9. Vacuum Arc Ion Sources: Recent Developments and Applications

    Energy Technology Data Exchange (ETDEWEB)

    Brown, Ian; Oks, Efim

    2005-05-01

    The vacuum arc ion source has evolved over the past twenty years into a standard laboratory tool for the production of high current beams of metal ions, and is now used in a number of different embodiments at many laboratories around the world. The primary application of this kind of source has evolved to be ion implantation for material surface modification. Another important use is for injection of high current beams of heavy metal ions into the front ends of particle accelerators, and much excellent work has been carried out in recent years in optimizing the source for reliable accelerator application. The source also provides a valuable tool for the investigation of the fundamental plasma physics of vacuum arc plasma discharges. As the use of the source has grown and diversified, at the same time the ion source performance and operational characteristics have been improved in a variety of different ways also. Here we review the growth and status of vacuum arc ion sources around the world, and summarize some of the applications for which the sources have been used.

  10. Bright focused ion beam sources based on laser-cooled atoms

    Science.gov (United States)

    McClelland, J. J.; Steele, A. V.; Knuffman, B.; Twedt, K. A.; Schwarzkopf, A.; Wilson, T. M.

    2016-01-01

    Nanoscale focused ion beams (FIBs) represent one of the most useful tools in nanotechnology, enabling nanofabrication via milling and gas-assisted deposition, microscopy and microanalysis, and selective, spatially resolved doping of materials. Recently, a new type of FIB source has emerged, which uses ionization of laser cooled neutral atoms to produce the ion beam. The extremely cold temperatures attainable with laser cooling (in the range of 100 μK or below) result in a beam of ions with a very small transverse velocity distribution. This corresponds to a source with extremely high brightness that rivals or may even exceed the brightness of the industry standard Ga+ liquid metal ion source. In this review we discuss the context of ion beam technology in which these new ion sources can play a role, their principles of operation, and some examples of recent demonstrations. The field is relatively new, so only a few applications have been demonstrated, most notably low energy ion microscopy with Li ions. Nevertheless, a number of promising new approaches have been proposed and/or demonstrated, suggesting that a rapid evolution of this type of source is likely in the near future. PMID:27239245

  11. Bright focused ion beam sources based on laser-cooled atoms

    Energy Technology Data Exchange (ETDEWEB)

    McClelland, J. J.; Wilson, T. M. [Center for Nanoscale Science and Technology, National Institute of Standards and Technology, Gaithersburg, Maryland 20899 (United States); Steele, A. V.; Knuffman, B.; Schwarzkopf, A. [Center for Nanoscale Science and Technology, National Institute of Standards and Technology, Gaithersburg, Maryland 20899 (United States); zeroK NanoTech, Gaithersburg, Maryland 20878 (United States); Twedt, K. A. [Center for Nanoscale Science and Technology, National Institute of Standards and Technology, Gaithersburg, Maryland 20899 (United States); Maryland Nanocenter, University of Maryland, College Park, Maryland 20742 (United States)

    2016-03-15

    Nanoscale focused ion beams (FIBs) represent one of the most useful tools in nanotechnology, enabling nanofabrication via milling and gas-assisted deposition, microscopy and microanalysis, and selective, spatially resolved doping of materials. Recently, a new type of FIB source has emerged, which uses ionization of laser cooled neutral atoms to produce the ion beam. The extremely cold temperatures attainable with laser cooling (in the range of 100 μK or below) result in a beam of ions with a very small transverse velocity distribution. This corresponds to a source with extremely high brightness that rivals or may even exceed the brightness of the industry standard Ga{sup +} liquid metal ion source. In this review, we discuss the context of ion beam technology in which these new ion sources can play a role, their principles of operation, and some examples of recent demonstrations. The field is relatively new, so only a few applications have been demonstrated, most notably low energy ion microscopy with Li ions. Nevertheless, a number of promising new approaches have been proposed and/or demonstrated, suggesting that a rapid evolution of this type of source is likely in the near future.

  12. Li+ alumino-silicate ion source development for the Neutralized Drift Compression Experiment (NDCX)

    Energy Technology Data Exchange (ETDEWEB)

    Roy, Prabir K.; Greenway, Wayne G.; Kwan, Joe W.; Seidl, Peter A.; Waldron, William L.; Wu, James K.

    2010-10-01

    We report results on lithium alumino-silicate ion source development in preparation for warmdense-matter heating experiments on the new Neutralized Drift Compression Experiment (NDCXII). The practical limit to the current density for a lithium alumino-silicate source is determined by the maximum operating temperature that the ion source can withstand before running into problems of heat transfer, melting of the alumino-silicate material, and emission lifetime. Using small prototype emitters, at a temperature of ~;;1275 oC, a space-charge-limited Li+ beam current density of J ~;;1 mA/cm2 was obtained. The lifetime of the ion source was ~;;50 hours while pulsing at a rate of 0.033 Hz with a pulse duration of 5-6 mu s.

  13. Development of DRAGON electron cyclotron resonance ion source at Institute of Modern Physics.

    Science.gov (United States)

    Lu, W; Xie, D Z; Zhang, X Z; Xiong, B; Ruan, L; Sha, S; Zhang, W H; Cao, Y; Lin, S H; Guo, J W; Fang, X; Guo, X H; Li, X X; Ma, H Y; Yang, Y; Wu, Q; Zhao, H Y; Ma, B H; Wang, H; Zhu, Y H; Feng, Y C; Li, J Y; Li, J Q; Sun, L T; Zhao, H W

    2012-02-01

    A new room temperature electron cyclotron resonance (ECR) ion source, DRAGON, is under construction at IMP. DRAGON is designed to operate at microwaves of frequencies of 14.5-18 GHz. Its axial solenoid coils are cooled with evaporative medium to provide an axial magnetic mirror field of 2.5 T at the injection and 1.4 T at the extraction, respectively. In comparison to other conventional room temperature ECR ion sources, DRAGON has so far the largest bore plasma chamber of inner diameter of 126 mm with maximum radial fields of 1.4-1.5 T produced by a non-Halbach permanent sextupole magnet.

  14. A Penning sputter ion source with very low energy spread

    Energy Technology Data Exchange (ETDEWEB)

    Nouri, Z., E-mail: znouri@uwo.c [Department of Physics and Astronomy, University of Western Ontario, London ON, N6A 3K7 (Canada); Li, R., E-mail: ruohong@triumf.c [TRIUMF, 4004 Wesbrook Mall, Vancouver BC, V6T 2A3 (Canada); Holt, R.A., E-mail: rholt@uwo.c [Department of Physics and Astronomy, University of Western Ontario, London ON, N6A 3K7 (Canada); Rosner, S.D., E-mail: rosner@uwo.c [Department of Physics and Astronomy, University of Western Ontario, London ON, N6A 3K7 (Canada)

    2010-03-01

    We have developed a version of the Frankfurt Penning ion source that produces ion beams with very low energy spreads of approx3 eV, while operating in a new discharge mode characterized by very high pressure, low voltage, and high current. The extracted ions also comprise substantial metastable and doubly charged species. Detailed studies of the operating parameters of the source showed that careful adjustment of the magnetic field and gas pressure is critical to achieving optimum performance. We used a laser-fluorescence method of energy analysis to characterize the properties of the extracted ion beam with a resolving power of 1x10{sup 4}, and to measure the absolute ion beam energy to an accuracy of 4 eV in order to provide some insight into the distribution of plasma potential within the ion source. This characterization method is widely applicable to accelerator beams, though not universal. The low energy spread, coupled with the ability to produce intense ion beams from almost any gas or conducting solid, make this source very useful for high-resolution spectroscopic measurements on fast-ion beams.

  15. Offline Ion Source Developments for the BECOLA Facility at NSCL

    Science.gov (United States)

    Klose, Andrew; Mantica, Paul; Minamisono, Kei

    2013-04-01

    Singly-charged beams of the stable isotope(s) of K, Ca, Mn, and Fe have been produced using either a commercial plasma ion source or a home-built electron ionization source for the BEam COoler and LAser spectroscopy (BECOLA) facility at the National Superconducting Cyclotron Laboratory (NSCL) at Michigan State University. For each element, collinear laser spectroscopy was performed to confirm the presence of the respective element. Production of stable ion beams for a given element is necessary to obtain reference hyperfine spectra of species with known electromagnetic moments before such nuclear properties can be deduced from the laser hyperfine-structure measurements of rare isotopes that are planned at NSCL. The results from the commissioning tests of the plasma and electron ionization sources will be presented, and development of a new Penning Ion Gauge (PIG) ion source will be discussed.

  16. Recent Operation of the FNAL Magnetron H- Ion Source

    Energy Technology Data Exchange (ETDEWEB)

    Karns, Patrick R. [Fermilab; Bollinger, D. S. [Fermilab; Sosa, A. [Fermilab

    2016-09-06

    This paper will detail changes in the operational paradigm of the Fermi National Accelerator Laboratory (FNAL) magnetron H- ion source due to upgrades in the accelerator system. Prior to November of 2012 the H- ions for High Energy Physics (HEP) experiments were extracted at ~18 keV vertically downward into a 90 degree bending magnet and accelerated through a Cockcroft-Walton accelerating column to 750 keV. Following the upgrade in the fall of 2012 the H- ions are now directly extracted from a magnetron at 35 keV and accelerated to 750 keV by a Radio Frequency Quadrupole (RFQ). This change in extraction energy as well as the orientation of the ion source required not only a redesign of the ion source, but an updated understanding of its operation at these new values. Discussed in detail are the changes to the ion source timing, arc discharge current, hydrogen gas pressure, and cesium delivery system that were needed to maintain consistent operation at >99% uptime for HEP, with an increased ion source lifetime of over 9 months.

  17. Size scaling of negative hydrogen ion sources for fusion

    Energy Technology Data Exchange (ETDEWEB)

    Fantz, U., E-mail: ursel.fantz@ipp.mpg.de; Franzen, P.; Kraus, W.; Schiesko, L.; Wimmer, C.; Wünderlich, D. [Max-Planck-Institut für Plasmaphysik, Boltzmannstr. 2, 85748 Garching (Germany)

    2015-04-08

    The RF-driven negative hydrogen ion source (H{sup −}, D{sup −}) for the international fusion experiment ITER has a width of 0.9 m and a height of 1.9 m and is based on a ⅛ scale prototype source being in operation at the IPP test facilities BATMAN and MANITU for many years. Among the challenges to meet the required parameters in a caesiated source at a source pressure of 0.3 Pa or less is the challenge in size scaling of a factor of eight. As an intermediate step a ½ scale ITER source went into operation at the IPP test facility ELISE with the first plasma in February 2013. The experience and results gained so far at ELISE allowed a size scaling study from the prototype source towards the ITER relevant size at ELISE, in which operational issues, physical aspects and the source performance is addressed, highlighting differences as well as similarities. The most ITER relevant results are: low pressure operation down to 0.2 Pa is possible without problems; the magnetic filter field created by a current in the plasma grid is sufficient to reduce the electron temperature below the target value of 1 eV and to reduce together with the bias applied between the differently shaped bias plate and the plasma grid the amount of co-extracted electrons. An asymmetry of the co-extracted electron currents in the two grid segments is measured, varying strongly with filter field and bias. Contrary to the prototype source, a dedicated plasma drift in vertical direction is not observed. As in the prototype source, the performance in deuterium is limited by the amount of co-extracted electrons in short as well as in long pulse operation. Caesium conditioning is much harder in deuterium than in hydrogen for which fast and reproducible conditioning is achieved. First estimates reveal a caesium consumption comparable to the one in the prototype source despite the large size.

  18. Arc Discharge Ion Source Development at CERN ISOLDE

    CERN Document Server

    Penescu, Liviu; Stora, Thierry; Catherall, Richard; Cata-Danil, Gheorghe

    2010-01-01

    Within a Marie Curie Early Stage Training project at CERN, a detailed study (experimental, analytical and numerical) of the standard ISOLDE FEBIAD ion sources has been done. A new theoretical model global source behavior could be inferred, based on the acquired experimental data. The source model already served to the development of two FEBIAD prototypes which improved the I+ ionization efficiencies for the noble gases by 5 to 20 times (depending on element) This development can now serve to future ion source optimizations, for specific user or facility requirements around the world, especially for the production of high intensity radioactive beams.

  19. Uncertainties in the heliosheath ion temperatures

    Directory of Open Access Journals (Sweden)

    K. Scherer

    2018-01-01

    Full Text Available The Voyager plasma observations show that the physics of the heliosheath is rather complex and that the temperature derived from observation particularly differs from expectations. To explain this fact, the temperature in the heliosheath should be based on κ distributions instead of Maxwellians because the former allows for much higher temperature. Here we show an easy way to calculate the κ temperatures when those estimated from the data are given as Maxwellian temperatures. We use the moments of the Maxwellian and κ distributions to estimate the κ temperature. Moreover, we show that the pressure (temperature given by a truncated κ distribution is similar to that given by a Maxwellian and only starts to increase for higher truncation velocities. We deduce a simple formula to convert the Maxwellian to κ pressure or temperature. We apply this result to the Voyager 2 observations in the heliosheath.

  20. Studies of an inductively coupled negative hydrogen ion radio frequency source through simulations and experiments

    Energy Technology Data Exchange (ETDEWEB)

    Bandyopadhyay, M.

    2004-08-24

    In the frame work of a development project for ITER neutral beam injection system a radio frequency (RF) driven negative hydrogen (H-/D-) ion source, (BATMAN ion source) is developed which is designed to produce several 10s of ampere of H-/D- beam current. This PhD work has been carried out to understand and optimize BATMAN ion source. The study has been done with the help of computer simulations, modeling and experiments. The complete three dimensional Monte-Carlo computer simulation codes have been developed under the scope of this PhD work. A comprehensive description about the volume production and the surface production of H- ions is presented in the thesis along with the study results obtained from the simulations, modeling and the experiments. One of the simulations is based on the volume production of H- ions, where it calculates the density profile of the vibrationally excited H2 molecules, the density profile of H- ions and the transport probability of those H- ions along the source axis towards the grid. The other simulation studies the transport of those H- ions which are produced on the surface of the plasma grid. It is expected that if there is a plasma flow in the source, the transport of plasma components (molecules and ions) would be influenced. Experimentally it is observed that there is a convective plasma flow exists in the ion source. A transverse magnetic filter field which is present near the grid inside the ion source reduces the flow velocity. Negative ions and electrons have the same sign of charge; therefore the electrons are co-extracted with the negative ions through the grid system, which is not desirable. It is observed that a magnetic field near the grid, magnetized the electrons and therefore reduce the co-extracted electron current. It is also observed experimentally that if the plasma grid is biased positively with respect to the source body, the electron density near the plasma grid is reduced and therefore the co

  1. Influence of Temperature and Ion Concentration on Sedimentation ...

    African Journals Online (AJOL)

    ADOWIE PERE

    2017-12-16

    Dec 16, 2017 ... precipitates. In this research study, the effects of temperature and ion concentration on the sedimentation of ... concentrations (< 0.04M) of the metal and phosphate ions markedly influenced the initial sedimentation rates of TCP and TSP .... When particle concentration is high, Stokes' equation may not show ...

  2. Lithium-ion Energy Storage at Very Low Temperatures Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Li-ion batteries with specific energy >180 Wh/kg, calendar life (>15years), and a wide operating temperature range (-60oC to 60oC) are crucial for the...

  3. A cesium-sputtering negative ion source for AMS investigations

    Science.gov (United States)

    Håkansson, K.; Hellborg, R.; Erlandsson, B.; Skog, G.; Stenström, K.; Wiebert, A.

    1996-02-01

    Accelerator mass spectrometry (AMS) requires ion sources delivering intense negative ion beams of high stability. At the Lund 3 MV Pelletron tandem accelerator a new Cs-sputtering source has therefore been constructed and installed. The source is equipped with a mechanism for automatically cracking the cesium galss ampoule inside the oven when the source is evacuated. The source is also equipped with a multiple sample holder which permits on-line sample changing without disrupting the operation of the electrostatic accelerator. In order to maximise the negative ion beam current the sample holder has a mechanism for moving the sample relative to the cesium beam. By doing this the lifetime of the samples can be increased.

  4. Deterministic ultracold ion source targeting the Heisenberg limit.

    Science.gov (United States)

    Schnitzler, W; Linke, N M; Fickler, R; Meijer, J; Schmidt-Kaler, F; Singer, K

    2009-02-20

    The major challenges to fabricate quantum processors and future nano-solid-state devices are material modification techniques with nanometer resolution and suppression of statistical fluctuations of dopants or qubit carriers. Based on a segmented ion trap with mK laser-cooled ions we have realized a deterministic single-ion source which could operate with a huge range of sympathetically cooled ion species, isotopes or ionic molecules. We have deterministically extracted a predetermined number of ions on demand and have measured a longitudinal velocity uncertainty of 6.3 m/s and a spatial beam divergence of 600 microrad. We show in numerical simulations that if the ions are cooled to the motional ground state (Heisenberg limit) nanometer spatial resolution can be achieved.

  5. Transverse coupling property of beam from ECR ion sources.

    Science.gov (United States)

    Yang, Y; Yuan, Y J; Sun, L T; Feng, Y C; Fang, X; Cao, Y; Lu, W; Zhang, X Z; Zhao, H W

    2014-11-01

    Experimental evidence of the property of transverse coupling of beam from Electron Cyclotron Resonance (ECR) ion source is presented. It is especially of interest for an ECR ion source, where the cross section of extracted beam is not round along transport path due to the magnetic confinement configuration. When the ions are extracted and accelerated through the descending axial magnetic field at the extraction region, the horizontal and vertical phase space strongly coupled. In this study, the coupling configuration between the transverse phase spaces of the beam from ECR ion source is achieved by beam back-tracking simulation based on the measurements. The reasonability of this coupling configuration has been proven by a series of subsequent simulations.

  6. Advanced light ion source extraction system for a new electron cyclotron resonance ion source geometry at Saclay

    Energy Technology Data Exchange (ETDEWEB)

    Delferriere, O.; Gobin, R.; Harrault, F.; Nyckees, S.; Sauce, Y.; Tuske, O. [Commissariat a l' Energie Atomique, CEA/Saclay, DSM/IRFU, 91191 Gif/Yvette (France)

    2012-02-15

    One of the main goal of intense light ion injector projects such as IPHI, IFMIF, or SPIRAL2, is to produce high current beams while keeping transverse emittance as low as possible. To prevent emittance growth induced in a dual solenoid low energy transfer line, its length has to be minimized. This can be performed with the advanced light ion source extraction system concept that we are developing: a new ECR 2.45 GHz type ion source based on the use of an additional low energy beam transport (LEBT) short length solenoid close to the extraction aperture to create the resonance in the plasma chamber. The geometry of the source has been considerably modified to allow easy maintenance of each component and to save space in front of the extraction. The source aims to be very flexible and to be able to extract high current ion beams at energy up to 100 kV. A specific experimental setup for this source is under installation on the BETSI test bench, to compare its performances with sources developed up to now in the laboratory, such as SILHI, IFMIF, or SPIRAL2 ECR sources. This original extraction source concept is presented, as well as electromagnetic simulations with OPERA-2D code. Ion beam extraction in space charge compensation regime with AXCEL, and beam dynamics simulation with SOLMAXP codes show the beam quality improvement at the end of the LEBT.

  7. Advanced light ion source extraction system for a new electron cyclotron resonance ion source geometry at Saclay.

    Science.gov (United States)

    Delferrière, O; Gobin, R; Harrault, F; Nyckees, S; Sauce, Y; Tuske, O

    2012-02-01

    One of the main goal of intense light ion injector projects such as IPHI, IFMIF, or SPIRAL2, is to produce high current beams while keeping transverse emittance as low as possible. To prevent emittance growth induced in a dual solenoid low energy transfer line, its length has to be minimized. This can be performed with the advanced light ion source extraction system concept that we are developing: a new ECR 2.45 GHz type ion source based on the use of an additional low energy beam transport (LEBT) short length solenoid close to the extraction aperture to create the resonance in the plasma chamber. The geometry of the source has been considerably modified to allow easy maintenance of each component and to save space in front of the extraction. The source aims to be very flexible and to be able to extract high current ion beams at energy up to 100 kV. A specific experimental setup for this source is under installation on the BETSI test bench, to compare its performances with sources developed up to now in the laboratory, such as SILHI, IFMIF, or SPIRAL2 ECR sources. This original extraction source concept is presented, as well as electromagnetic simulations with OPERA-2D code. Ion beam extraction in space charge compensation regime with AXCEL, and beam dynamics simulation with SOLMAXP codes show the beam quality improvement at the end of the LEBT.

  8. Review of ion-source developments for radioactive ion-beam facilities

    CERN Document Server

    Lettry, Jacques

    1999-01-01

    The ion-sources dedicated to the production of radioactive ion beams (RIB) shall be highly efficient, selective and fast. This efficiency is mandatory since only limited amounts of radionuclides are produced. Chemical selectivity is needed to confine other elements near to the production site and to suppress isobaric contaminants. Eventually, the ion-source shall only decay the radioisotopes by a fraction of their half-life to reduce decay losses. The world wide spread RIB facilities came up with a large variety of solutions to meet part or all of these requirements such as: ion traps, surface, plasma, sputtering, electron cyclotron resonance and laser ion- sources. In this review, the latest developments are presented and their applications to charge states breeder systems proposed for post-acceleration are discussed. (59 refs).

  9. Optimization of ECR singly-charged ion sources for the radioactive ion beam production

    CERN Document Server

    Jardin, P; Gaubert, G; Pacquet, J Y; Drobert, T; Cornell, J; Barue, C; Canet, C; Dupuis, M; Flambard, J L; Lecesne, N; Leherissier, P; Lemagnen, F; Leroy, R

    2003-01-01

    Measurements of the transformation time of atoms into ions were carried out with two 2.45 GHz electron cyclotron resonance ion sources (ECRIS) in the case of the simple ionization of He, Ne, Ar and Kr gases. The effect of the plasma volume, of the dead volumes and of the ionization efficiency are presented. Some rules are deduced for the design of the next ECRIS dedicated to radioactive ion production with noble gases.

  10. Microwave ion source for accelerator driven sub-critical system

    CERN Document Server

    Cui Bao Qun; Jiang Wei; LiLiQiang; WangRongWen

    2002-01-01

    A microwave ion source is under developing for a demonstration prototype of a accelerator driven sub-critical system at CIAE (China Institute of Atomic Energy), 100 mA hydrogen beam has been extracted from the source through a 7.3 mm aperture in diameter, proton ratio is more than 85%, reliability has been tested for 100 h without any failures

  11. Beam optics optimization of a negative-ion sputter source

    Indian Academy of Sciences (India)

    A negative-ion sputter source has been studied in order to increase the beam intensity delivered by the Vivitron tandem injector. The aim was to characterize the influence on the beam intensity of some factors related to the configuration of the source such as the shape of the target holder, the target surface topography and ...

  12. Selective minority-ion heating in the afterglow of an electron cyclotron resonance ion source

    NARCIS (Netherlands)

    Nadzeyka, A; Meyer, D; Barzangy, F; Drentje, AG; Wiesemann, K

    We report first experimental results on selective minority-ion heating in the afterglow mode of electron cyclotron resonance ion sources in Bochum and at the KVI (Groningen) in mixtures of Ar/O/He and in pure nitrogen. In addition we measured time resolved vacuum ultraviolet-line intensities of

  13. Status and Operation of the Linac4 Ion Source Prototypes

    CERN Document Server

    Lettry, J; Andersson, P; Bertolo, S; Butterworth, A; Coutron, Y; Dallocchio, A; Chaudet, E; Gil-Flores, J; Guida, R; Hansen, J; Koszar, I; Mahner, E; Mastrostefano, C; Mathot, S; Mattei, S; Midttun, O; Moyret, P; Nisbet, D; O’Neil, M; Paoluzzi, M; Pasquino, C; Pereira, H; Rochez, J; Sanchez Alvarez, J; Sanchez Arias, J; Scrivens, R; Steyaert, D; Thaus, N; Hatayama, A; Nishida, K; Shibata, T; Yamamot, T; Otha, M

    2014-01-01

    CERN’s Linac4 45 kV H- ion sources prototypes are installed at a dedicated ion source test stand and in the Linac4 tunnel. The operation of the pulsed hydrogen injection, RF sustained plasma and pulsed high voltages are described. The first experimental results of two prototypes relying on 2MHz RF- plasma heating are presented. The plasma is ignited via capacitive coupling, and sustained by inductive coupling. The light emitted from the plasma is collected by viewports pointing to the plasma chamber wall in the middle of the RF solenoid and to the plasma chamber axis. Preliminary measurements of optical emission spectroscopy and photometry of the plasma have been performed. The design of a cesiated ion source is presented. The volume source has produced a 45 keV H- beam of 16-22 mA which has successfully been used for the commissioning of the LEBT, RFQ and chopper of Linac4.

  14. Overview of ion source characterization diagnostics in INTF

    Energy Technology Data Exchange (ETDEWEB)

    Bandyopadhyay, M., E-mail: mainak@iter-india.org; Sudhir, Dass; Bhuyan, M.; Tyagi, H.; Joshi, J.; Yadav, A.; Rotti, C.; Parmar, Deepak; Patel, H.; Pillai, S.; Chakraborty, A. [ITER-India, Institute for Plasma Research, A-29 GIDC, Sector-25, Gandhinagar, Gujarat 382016 (India); Soni, J. [Institute for Plasma Research, Bhat, Gandhinagar, Gujarat 382 428 (India)

    2016-02-15

    INdian Test Facility (INTF) is envisaged to characterize ITER diagnostic neutral beam system and to establish the functionality of its eight inductively coupled RF plasma driver based negative hydrogen ion source and its beamline components. The beam quality mainly depends on the ion source performance and therefore, its diagnostics plays an important role for its safe and optimized operation. A number of diagnostics are planned in INTF to characterize the ion source performance. Negative ions and its cesium contents in the source will be monitored by optical emission spectroscopy (OES) and cavity ring down spectroscopy. Plasma near the extraction region will be studied using standard electrostatic probes. The beam divergence and negative ion stripping losses are planned to be measured using Doppler shift spectroscopy. During initial phase of ion beam characterization, carbon fiber composite based infrared imaging diagnostics will be used. Safe operation of the beam will be ensured by using standard thermocouples and electrical voltage-current measurement sensors. A novel concept, based on plasma density dependent plasma impedance measurement using RF electrical impedance matching parameters to characterize the RF driver plasma, will be tested in INTF and will be validated with OES data. The paper will discuss about the overview of the complete INTF diagnostics including its present status of procurement, experimentation, interface with mechanical systems in INTF, and integration with INTF data acquisition and control systems.

  15. Construction of the superconducting ECR ion source Venus

    Energy Technology Data Exchange (ETDEWEB)

    Leitner, M.A.; Lyneis, C.M.; Wutte, D.C.; Taylor, C.E.; Abbott, S.R. [Lawrence Berkeley National Lab., CA (United States)

    2001-07-01

    A new, very high magnetic field superconducting ECR ion source, VENUS, is under development at the LBNL 88-inch cyclotron. It will boost the maximum energies and intensities for heavy ions from the cyclotron particularly for ions with mass greater than 60. It will also serve as R and D ion source for the proposed rare isotope accelerator (RIA) project in the US, which requires up to 10 p{mu}A of U{sup 30+}. The superconducting magnet structure consists of three solenoids and six racetrack coils with iron poles forming the sextupole. The coils are designed to generate a 4 T axial mirror field at injection and 3 T at extraction and a radial sextupole field of 2.4 T at the plasma chamber wall. Test results of the magnet coils, which exceeded design requirements with minimum training, are presented. The magnet assembly with its cryostat will be enclosed by an iron shield and therefore must be designed to withstand any possible forces between coils and iron, which can be as high as 3.4.10{sup 5} N (35,000 kgf). The low energy beam transport line (LEBT) and mass analyzing system of the ion source is designed to transport a proton-equivalent current of 25 mA at 20 kV extraction voltage. The design of the ion source and LEBT will be discussed. (orig.)

  16. Ion pinhole imaging diagnostics on fast ion source in femtosecond laser plasma of cluster targets.

    Science.gov (United States)

    Makarov, Sergey; Pikuz, Sergey; Faenov, Anatoly; Pikuz, Tatiana; Fukuda, Yuji; Skobelev, Igor; Zhvaniya, Irina; Varzar, Sergey; Kando, Masaki; Kodama, Ryousuke

    2017-07-10

    The spatial configuration of the ion source generated under femtosecond laser interaction with clusters is investigated. While intense laser pulses (36 fs, 60 mJ, intensity of 4 × 1017 W/cm2) propagated in CO2 cluster (~0.22 μm in diameter) media, the shape of the obtained plasma ion source was registered for the first time by means of pinhole imaging method. The remarkable decrease in fast ion yield in the vicinity of the assumed best laser focus near the gas cluster jet axis is observed. Such observed anisotropy of the ion source is suggested to originate from the influence of the laser prepulse destroying clusters in advance to the arrival of the main pulse. The assumption is confirmed by optical shadowgraphy images of the plasma channel and is important for further development of an efficient laser-plasma-based fast ion source. Following the observed geometry of the ion source, the laser intensity limit allowing to accelerate ions to ~100 keV energy range was estimated.

  17. Ion Based High-Temperature Pressure Sensor

    National Research Council Canada - National Science Library

    Zdenek, Jeffrey S; Anthenien, Ralph A

    2004-01-01

    .... The environment encountered in such engines necessitates high temperature and durable (vibration resistant) devices. Traditional pressure sensors can be used, however thermal insulating materials must be used to protect the diaphragm...

  18. Electron beam ion sources for student education at universities

    Energy Technology Data Exchange (ETDEWEB)

    Ritter, Erik [DREEBIT GmbH, Dresden (Germany); Zschornack, Guenter [TU Dresden, Dresden (Germany)

    2014-07-01

    Ion beams have become essential tools used in many fields of fundamental research as well as industrial applications. Thus, it is important for todays physics students to understand the basics of ion beam creation, transportation as well as ion-surface interactions. We present results from laboratory training courses using table-top sized electron beam ion sources of the Dresden EBIT type which is able to produce a large spectrum of ions with low or high charge states. The initial ion beam is guided through several ion optical elements like Einzel lenses and deflectors, is separated by the charge-to-mass ratio of its components with a Wien-Filter or dipole analyzing magnet and is detected in a Faraday Cup. A specific assembly for laboratory training as used at the Technische Universitaet Dresden and the Jagiellonian University in Krakow, Poland, is introduced. In typical experiments, students analyze the charge-to-mass ratio spectrum from a Dresden EBIT measured using a Wien Filter. The composition of the extracted ion beam can be manipulated by the gas pressure or the ionisation time. In a wider context, the atomic physics processes occurring especially during the production of highly charged ions also appear in nuclear fusion facilities as well as in many astrophysical phenomena, for example supernovas. Such aspects can be discussed in order to help students connect to modern research carried out at large international facilities.

  19. Anomalous ion thermal transport in hot ion plasmas by the ion temperature gradient mode

    Energy Technology Data Exchange (ETDEWEB)

    Kim, J.Y.; Horton, W. (Texas Univ., Austin, TX (United States). Inst. for Fusion Studies); Coppi, B. (Massachusetts Inst. of Tech., Cambridge, MA (United States). Research Lab. of Electronics)

    1992-01-01

    Experiments show that the observed radial profiles of the ion thermal conductivity {chi}{sub i} have the opposite shapes with those obtained from the ion temperature gradient mode ({eta}{sub i} mode) turbulence model by the traditional mixing length estimate. In this work, this radial profile problem is reconsidered with an electromagnetic study of the linear stability of the toroidal {eta}{sub i} mode and a new rule for choosing the mixing length. It is first shown that the electromagnetic effect gives a significant stabilizing effect on the toroidal {eta}{sub i} mode, and that the observed reduction of {chi}{sub i}(r) in the core region can be explained by this electromagnetic effect. Secondly, in view of earlier numerical simulations showing the transfer of fluctuation energy to larger scales that those for the fastest growth rate, as well as fluctuation measurements indicating longer radial correlation lengths, a new mixing length formula is proposed to explain the radial increase of the {chi}{sub i}. It is shown the new formula fits well the observed {chi}{sub i}(r) profiles in two TFTR supershot discharges and also gives the scaling law in the current and the magnetic field which agrees better with experiment than the conventional formula.

  20. Anomalous ion thermal transport in hot ion plasmas by the ion temperature gradient mode

    Energy Technology Data Exchange (ETDEWEB)

    Kim, J.Y.; Horton, W. [Texas Univ., Austin, TX (United States). Inst. for Fusion Studies; Coppi, B. [Massachusetts Inst. of Tech., Cambridge, MA (United States). Research Lab. of Electronics

    1992-08-01

    Experiments show that the observed radial profiles of the ion thermal conductivity {chi}{sub i} have the opposite shapes with those obtained from the ion temperature gradient mode ({eta}{sub i} mode) turbulence model by the traditional mixing length estimate. In this work, this radial profile problem is reconsidered with an electromagnetic study of the linear stability of the toroidal {eta}{sub i} mode and a new rule for choosing the mixing length. It is first shown that the electromagnetic effect gives a significant stabilizing effect on the toroidal {eta}{sub i} mode, and that the observed reduction of {chi}{sub i}(r) in the core region can be explained by this electromagnetic effect. Secondly, in view of earlier numerical simulations showing the transfer of fluctuation energy to larger scales that those for the fastest growth rate, as well as fluctuation measurements indicating longer radial correlation lengths, a new mixing length formula is proposed to explain the radial increase of the {chi}{sub i}. It is shown the new formula fits well the observed {chi}{sub i}(r) profiles in two TFTR supershot discharges and also gives the scaling law in the current and the magnetic field which agrees better with experiment than the conventional formula.

  1. An intense ECR ion source for proton linac

    CERN Document Server

    Cui Bao Qun; Bao Yi We; Jiang Wei; Wang Rong

    2002-01-01

    An intense electron cyclotron resonance ion source for proton linac has been developed. At 30 keV, 100 mA hydrogen beam is extracted from the source. The proton ratio is greater than 85% and the beam density of 340 mA/Cm sup 2 is achieved. The rms emittance of the beam is around 0.11 pi mm centre dot mrad. The source has passed 100 h reliability test

  2. The ion temperature gradient: An intrinsic property of Earth's magnetotail

    Science.gov (United States)

    Lu, San; Artemyev, A. V.; Angelopoulos, V.; Lin, Y.; Wang, X. Y.

    2017-08-01

    Although the ion temperature gradient along (XGSM) and across (ZGSM) the Earth's magnetotail, which plays a key role in generating the cross-tail current and establishing pressure balance with the lobes, has been extensively observed by spacecraft, the mechanism responsible for its formation is still unknown. We use multispacecraft observations and three-dimensional (3-D) global hybrid simulations to reveal this mechanism. Using THEMIS (Time History of Events and Macroscale Interactions during Substorms), Geotail, and ARTEMIS (Acceleration, Reconnection, Turbulence and Electrodynamics of Moon's Interaction with the Sun) observations during individual, near-simultaneous plasma sheet crossings from 10 to 60 RE, we demonstrate that the ion temperature ZGSM profile is bell-shaped at different geocentric distances. This ZGSM profile is also prevalent in statistics of 200 THEMIS current sheet crossings in the near-Earth region. Using 3-D global hybrid simulations, we show that mapping of the XGSM gradient of ion temperature along magnetic field lines produces such a bell-shaped profile. The ion temperature mapping along magnetic field lines in the magnetotail enables construction of two-dimensional distributions of these quantities from vertical (north-south) spacecraft crossings. Our findings suggest that the ion temperature gradient is an intrinsic property of the magnetotail that should be considered in kinetic descriptions of the magnetotail current sheet. Toward this goal, we use theoretical approaches to incorporate the temperature gradient into kinetic current sheet models, making them more realistic.

  3. Generation of multi-charged high current ion beams using the SMIS 37 gas-dynamic electron cyclotron resonance (ECR) ion source

    Energy Technology Data Exchange (ETDEWEB)

    Dorf, M. A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Zorin, V. G. [Russian Academy of Sciences (RAS), Nizhny Novgorod (Russian Federation). Inst. of Applied Physics; Sidorov, A. V. [Russian Academy of Sciences (RAS), Nizhny Novgorod (Russian Federation). Inst. of Applied Physics; Bokhanov, A. F. [Russian Academy of Sciences (RAS), Nizhny Novgorod (Russian Federation). Inst. of Applied Physics; Izotov, I. V. [Russian Academy of Sciences (RAS), Nizhny Novgorod (Russian Federation). Inst. of Applied Physics; Razin, S. V. [Russian Academy of Sciences (RAS), Nizhny Novgorod (Russian Federation). Inst. of Applied Physics; Skalyga, V. A. [Russian Academy of Sciences (RAS), Nizhny Novgorod (Russian Federation). Inst. of Applied Physics

    2013-06-02

    A gas-dynamic ECR ion source (GaDIS) is distinguished by its ability to produce high current and high brightness beams of moderately charged ions. Contrary to a classical ECR ion source where the plasma confinement is determined by the slow electron scattering into an empty loss-cone, the higher density and lower electron temperature in a GaDIS plasma lead to an isotropic electron distribution with the confinement time determined by the prompt gas-dynamic flow losses. As a result, much higher ion fluxes are available, however a decrease in the confinement time of the GaDIS plasma lowers the ion charge state. The gas-dynamic ECR ion source concept has been successfully realized in the SMIS 37 experimental facility operated at the Institute of Applied Physics, Russia. The use of high-power (~100 kW) microwave (37.5 GHz) radiation provides a dense plasma (~1013 cm-3) with a relatively low electron temperature (~50- 100 eV) and allows for the generation of high current (~1 A/cm2) beams of multi-charged ions. In this work we report on the present status of the SMIS 37 ion source and discuss the advanced numerical modeling of ion beam extraction using the particle-in-cell code WARP

  4. Fast-ion-beam laser probing of ion-source energy distributions and atomic structure

    Energy Technology Data Exchange (ETDEWEB)

    Holt, Richard A., E-mail: rholt@uwo.ca; Rosner, S. David [University of Western Ontario, Physics and Astronomy Department (Canada)

    2013-04-15

    Collinear fast-ion-beam laser spectroscopy is a very high resolution probe for measuring ion-beam energy distributions and atomic structure parameters of interest in nuclear physics, atomic physics, and astrophysics. We have used offline 10-keV beams of atomic ions and a CW laser system to study the behavior of a Penning ion source and to measure hyperfine structure, isotope shifts, atomic lifetimes, spontaneous-emission branching fractions, oscillator strengths, and absolute wavelengths of a variety of atomic species from the lanthanide and transition-metal groups.

  5. Shutterless ion mobility spectrometer with fast pulsed electron source

    Science.gov (United States)

    Bunert, E.; Heptner, A.; Reinecke, T.; Kirk, A. T.; Zimmermann, S.

    2017-02-01

    Ion mobility spectrometers (IMS) are devices for fast and very sensitive trace gas analysis. The measuring principle is based on an initial ionization process of the target analyte. Most IMS employ radioactive electron sources, such as 63Ni or 3H. These radioactive materials have the disadvantage of legal restrictions and the electron emission has a predetermined intensity and cannot be controlled or disabled. In this work, we replaced the 3H source of our IMS with 100 mm drift tube length with our nonradioactive electron source, which generates comparable spectra to the 3H source. An advantage of our emission current controlled nonradioactive electron source is that it can operate in a fast pulsed mode with high electron intensities. By optimizing the geometric parameters and developing fast control electronics, we can achieve very short electron emission pulses for ionization with high intensities and an adjustable pulse width of down to a few nanoseconds. This results in small ion packets at simultaneously high ion densities, which are subsequently separated in the drift tube. Normally, the required small ion packet is generated by a complex ion shutter mechanism. By omitting the additional reaction chamber, the ion packet can be generated directly at the beginning of the drift tube by our pulsed nonradioactive electron source with only slight reduction in resolving power. Thus, the complex and costly shutter mechanism and its electronics can also be omitted, which leads to a simple low-cost IMS-system with a pulsed nonradioactive electron source and a resolving power of 90.

  6. An inductively heated hot cavity catcher laser ion source

    Energy Technology Data Exchange (ETDEWEB)

    Reponen, M., E-mail: mikael.reponen@riken.jp [Nuclear Physics Group, School of Physics and Astronomy, Schuster Laboratory, The University of Manchester, Brunswick Street, Manchester M13 9PL (United Kingdom); Moore, I. D., E-mail: iain.d.moore@jyu.fi; Pohjalainen, I.; Savonen, M.; Voss, A. [Department of Physics, University of Jyväskylä, Survontie 9, FI-40014 Jyväskylä (Finland); Rothe, S. [CERN, CH-1211, Geneva 23 (Switzerland); Sonnenschein, V. [Department of Quantum Engineering, Nagoya University, Nagoya, Aichi 464-8603 (Japan)

    2015-12-15

    An inductively heated hot cavity catcher has been constructed for the production of low-energy ion beams of exotic, neutron-deficient Ag isotopes. A proof-of-principle experiment has been realized by implanting primary {sup 107}Ag{sup 21+} ions from a heavy-ion cyclotron into a graphite catcher. A variable-thickness nickel foil was used to degrade the energy of the primary beam in order to mimic the implantation depth expected from the heavy-ion fusion-evaporation recoils of N = Z {sup 94}Ag. Following implantation, the silver atoms diffused out of the graphite and effused into the catcher cavity and transfer tube, where they were resonantly laser ionized using a three-step excitation and ionization scheme. Following mass separation, the ions were identified by scanning the frequency of the first resonant excitation step while recording the ion count rate. Ion release time profiles were measured for different implantation depths and cavity temperatures with the mean delay time varying from 10 to 600 ms. In addition, the diffusion coefficients for silver in graphite were measured for temperatures of 1470 K, 1630 K, and 1720 K, from which an activation energy of 3.2 ± 0.3 eV could be determined.

  7. Accessibility condition of wave propagation and multicharged ion production in electron cyclotron resonance ion source plasma.

    Science.gov (United States)

    Kato, Yushi; Yano, Keisuke; Nishiokada, Takuya; Nagaya, Tomoki; Kimura, Daiju; Kumakura, Sho; Imai, Youta; Hagino, Shogo; Otsuka, Takuro; Sato, Fuminobu

    2016-02-01

    A new tandem type source of electron cyclotron resonance (ECR) plasmas has been constructing for producing synthesized ion beams in Osaka University. Magnetic mirror field configuration with octupole magnets can be controlled to various shape of ECR zones, namely, in the 2nd stage plasma to be available by a pair mirror and a supplemental coil. Noteworthy correlations between these magnetic configurations and production of multicharged ions are investigated in detail, as well as their optimum conditions. We have been considering accessibility condition of electromagnetic and electrostatic waves propagating in ECR ion source plasma, and then investigated their correspondence relationships with production of multicharged ions. It has been clarified that there exits efficient configuration of ECR zones for producing multicharged ion beams experimentally, and then has been suggested from detail accessibility conditions on the ECR plasma that new resonance, i.e., upper hybrid resonance, must have occurred.

  8. Shunting arc plasma source for pure carbon ion beam.

    Science.gov (United States)

    Koguchi, H; Sakakita, H; Kiyama, S; Shimada, T; Sato, Y; Hirano, Y

    2012-02-01

    A plasma source is developed using a coaxial shunting arc plasma gun to extract a pure carbon ion beam. The pure carbon ion beam is a new type of deposition system for diamond and other carbon materials. Our plasma device generates pure carbon plasma from solid-state carbon material without using a hydrocarbon gas such as methane gas, and the plasma does not contain any hydrogen. The ion saturation current of the discharge measured by a double probe is about 0.2 mA∕mm(2) at the peak of the pulse.

  9. Ion beams in SEM : An experiment towards a high brightness low energy spread electron impact gas ion source

    NARCIS (Netherlands)

    Jun, D.S.; Kutchoukov, V.G.; Kruit, P.

    2011-01-01

    A next generation ion source suitable for both high resolution focused ion beam milling and imaging applications is currently being developed. The new ion source relies on a method of which positively charged ions are extracted from a miniaturized gas chamber where neutral gas atoms become ionized

  10. Intense highly charged ion beam production and operation with a superconducting electron cyclotron resonance ion source

    Directory of Open Access Journals (Sweden)

    H. W. Zhao

    2017-09-01

    Full Text Available The superconducting electron cyclotron resonance ion source with advanced design in Lanzhou (SECRAL is a superconducting-magnet-based electron cyclotron resonance ion source (ECRIS for the production of intense highly charged heavy ion beams. It is one of the best performing ECRISs worldwide and the first superconducting ECRIS built with an innovative magnet to generate a high strength minimum-B field for operation with heating microwaves up to 24–28 GHz. Since its commissioning in 2005, SECRAL has so far produced a good number of continuous wave intensity records of highly charged ion beams, in which recently the beam intensities of ^{40}Ar^{12+} and ^{129}Xe^{26+} have, for the first time, exceeded 1 emA produced by an ion source. Routine operations commenced in 2007 with the Heavy Ion accelerator Research Facility in Lanzhou (HIRFL, China. Up to June 2017, SECRAL has been providing more than 28,000 hours of highly charged heavy ion beams to the accelerator demonstrating its great capability and reliability. The great achievement of SECRAL is accumulation of numerous technical advancements, such as an innovative magnetic system and an efficient double-frequency (24+18  GHz heating with improved plasma stability. This article reviews the development of SECRAL and production of intense highly charged ion beams by SECRAL focusing on its unique magnet design, source commissioning, performance studies and enhancements, beam quality and long-term operation. SECRAL development and its performance studies representatively reflect the achievements and status of the present ECR ion source, as well as the ECRIS impacts on HIRFL.

  11. Intense highly charged ion beam production and operation with a superconducting electron cyclotron resonance ion source

    Science.gov (United States)

    Zhao, H. W.; Sun, L. T.; Guo, J. W.; Lu, W.; Xie, D. Z.; Hitz, D.; Zhang, X. Z.; Yang, Y.

    2017-09-01

    The superconducting electron cyclotron resonance ion source with advanced design in Lanzhou (SECRAL) is a superconducting-magnet-based electron cyclotron resonance ion source (ECRIS) for the production of intense highly charged heavy ion beams. It is one of the best performing ECRISs worldwide and the first superconducting ECRIS built with an innovative magnet to generate a high strength minimum-B field for operation with heating microwaves up to 24-28 GHz. Since its commissioning in 2005, SECRAL has so far produced a good number of continuous wave intensity records of highly charged ion beams, in which recently the beam intensities of 40Ar+ and 129Xe26+ have, for the first time, exceeded 1 emA produced by an ion source. Routine operations commenced in 2007 with the Heavy Ion accelerator Research Facility in Lanzhou (HIRFL), China. Up to June 2017, SECRAL has been providing more than 28,000 hours of highly charged heavy ion beams to the accelerator demonstrating its great capability and reliability. The great achievement of SECRAL is accumulation of numerous technical advancements, such as an innovative magnetic system and an efficient double-frequency (24 +18 GHz ) heating with improved plasma stability. This article reviews the development of SECRAL and production of intense highly charged ion beams by SECRAL focusing on its unique magnet design, source commissioning, performance studies and enhancements, beam quality and long-term operation. SECRAL development and its performance studies representatively reflect the achievements and status of the present ECR ion source, as well as the ECRIS impacts on HIRFL.

  12. The Leuven isotope separator on-line laser ion source

    CERN Document Server

    Kudryavtsev, Y; Franchoo, S; Huyse, M; Gentens, J; Kruglov, K; Müller, W F; Prasad, N V S; Raabe, R; Reusen, I; Van den Bergh, P; Van Duppen, P; Van Roosbroeck, J; Vermeeren, L; Weissman, L

    2002-01-01

    An element-selective laser ion source has been used to produce beams of exotic radioactive nuclei and to study their decay properties. The operational principle of the ion source is based on selective resonant laser ionization of nuclear reaction products thermalized and neutralized in a noble gas at high pressure. The ion source has been installed at the Leuven Isotope Separator On-Line (LISOL), which is coupled on-line to the cyclotron accelerator at Louvain-la-Neuve. sup 5 sup 4 sup , sup 5 sup 5 Ni and sup 5 sup 4 sup , sup 5 sup 5 Co isotopes were produced in light-ion-induced fusion reactions. Exotic nickel, cobalt and copper nuclei were produced in proton-induced fission of sup 2 sup 3 sup 8 U. The b decay of the sup 6 sup 8 sup - sup 7 sup 4 Ni, sup 6 sup 7 sup - sup 7 sup 0 Co, sup 7 sup 0 sup - sup 7 sup 5 Cu and sup 1 sup 1 sup 0 sup - sup 1 sup 1 sup 4 Rh isotopes has been studied by means of beta-gamma and gamma-gamma spectroscopy. Recently, the laser ion source has been used to produce neutron-d...

  13. [Preliminary study of atomic emission spectrometry of Ti (H) plasma produced by vacuum arc ion source].

    Science.gov (United States)

    Deng, Chun-Feng; Wu, Chun-Lei; Wang, Yi-Fu; Lu, Biao; Wen, Zhong-Wei

    2014-03-01

    In order to study the discharge process of vacuum arc ion source, make a detail description of the discharge plasma, and lay the foundation for further research on ion source, atomic emission spectrometry was used to diagnose the parameters of plasma produced by vaccum arc ion source. In the present paper, two kinds of analysis method for the emission spectra data collected by a spectrometer were developed. Those were based in the stark broadening of spectral lines and Saba-Boltzmann equation. Using those two methods, the electron temperature, electron number density and the ion temperature of the plasma can be determined. The emission spectroscopy data used in this paper was collected from the plasma produced by a vacuum are ion source whose cathode was made by Ti material (which adsorbed hydrogen during storage procedure). Both of the two methods were used to diagnose the plasma parameters and judge the thermal motion state of the plasma. Otherwise, the validity of the diagnostic results by the two methods were analyzed and compared. In addition, the affection from laboratory background radiation during the spectral acquisition process was discussed.

  14. Ion angular distribution in plasma of vacuum arc ion source with composite cathode and elevated gas pressure.

    Science.gov (United States)

    Nikolaev, A G; Savkin, K P; Yushkov, G Yu; Oks, E M

    2014-02-01

    The Metal Vapor Vacuum Arc (MEVVA) ion sources are capable of generating ion beams of almost all metals of the periodic table. For this kind of ion source, a combination of gas feeding with magnetic field allows the simultaneous generation of both metal and gaseous ions. That makes the MEVVA ion source an excellent instrument for science and application. This work presents results of investigation for ion angular distributions in vacuum arc plasma of Mevva-V.Ru ion source for composite cathodes and for elevated gas pressure. It was shown that for all the cathode materials, singly charged ions have wider angular distribution than multiply charged ions. Increasing the working gas pressure leads to a significant change in the angular distribution of gaseous ions, while with the distribution of metal ions gas remains practically unchanged. The reasons for such different influences are discussed.

  15. Ion beam production and study of radioactive isotopes with the laser ion source at ISOLDE

    Science.gov (United States)

    Fedosseev, Valentin; Chrysalidis, Katerina; Day Goodacre, Thomas; Marsh, Bruce; Rothe, Sebastian; Seiffert, Christoph; Wendt, Klaus

    2017-08-01

    At ISOLDE the majority of radioactive ion beams are produced using the resonance ionization laser ion source (RILIS). This ion source is based on resonant excitation of atomic transitions by wavelength tunable laser radiation. Since its installation at the ISOLDE facility in 1994, the RILIS laser setup has been developed into a versatile remotely operated laser system comprising state-of-the-art solid state and dye lasers capable of generating multiple high quality laser beams at any wavelength in the range of 210-950 nm. A continuous programme of atomic ionization scheme development at CERN and at other laboratories has gradually increased the number of RILIS-ionized elements. At present, isotopes of 40 different elements have been selectively laser-ionized by the ISOLDE RILIS. Studies related to the optimization of the laser-atom interaction environment have yielded new laser ion source types: the laser ion source and trap and the versatile arc discharge and laser ion source. Depending on the specific experimental requirements for beam purity or versatility to switch between different ionization mechanisms, these may offer a favourable alternative to the standard hot metal cavity configuration. In addition to its main purpose of ion beam production, the RILIS is used for laser spectroscopy of radioisotopes. In an ongoing experimental campaign the isotope shifts and hyperfine structure of long isotopic chains have been measured by the extremely sensitive in-source laser spectroscopy method. The studies performed in the lead region were focused on nuclear deformation and shape coexistence effects around the closed proton shell Z = 82. The paper describes the functional principles of the RILIS, the current status of the laser system and demonstrated capabilities for the production of different ion beams including the high-resolution studies of short-lived isotopes and other applications of RILIS lasers for ISOLDE experiments. This article belongs to the Focus on

  16. Angular distribution of plasma in the vacuum arc ion source.

    Science.gov (United States)

    Nikolaev, A G; Yushkov, G Yu; Savkin, K P; Oks, E M

    2012-02-01

    This paper presents measurements of the angular distribution of the plasma components and different charge states of metal ions generated by a MEVVA-type ion source and measured by a time-of-flight mass-spectrometer. The experiments were performed for different cathode materials (Al, Cu, and Ti) and for different parameters of the vacuum arc discharge. The results are compared with prior results reported by other authors. The influence of different discharge parameters on the angular distribution in a vacuum arc source is discussed.

  17. Spacecraft mass spectrometer ion source employing field emission cathodes

    Science.gov (United States)

    Curtis, C. C.; Hsieh, K. C.

    1986-01-01

    An ion source that utilizes a pair of thin-film field emission cathodes to provide current for electric impact ionization is studied. The field emission cathodes are composed of microscopically small needle tips and an extraction electrode; the cathodes generate a 200-eV, 0.1-mA electron beam. The multistep process for the manufacturing of the field emission cathodes is examined. The operation of the ion source, which ionizes atoms and molecules that enter the mass spectrometer with a ram velocity of about 80 km/sec, is described.

  18. Thermo-mechanical design of the extraction grids for RF negative ion source at HUST

    Energy Technology Data Exchange (ETDEWEB)

    Zuo, Chen; Liu, Kaifeng, E-mail: kfliuhust@hust.edu.cn; Li, Dong; Mei, Zhiyuan; Zhang, Zhe; Chen, Dezhi

    2017-01-15

    Highlights: • An extraction system with cooling channels has been designed for HUST negative ion source. • Corresponding heat loads onto three grids has been used in thermo-mechanical analysis. • The analysis results could be very useful for driving the engineering design. - Abstract: Huazhong University of Science and Technology (HUST) is developing a small radio frequency negative ion source experimental setup to promote research on neutral beam injection ion sources. The extraction system for the negative ion source is the key component to obtain the negative ions. The extraction system is composed of three grids: the plasma grid, the extraction grid and the grounded grid. Each grid is impacted by different heat loads. As the grids have to fulfil specific requirements regarding ion extraction, beam optics, and thermo-mechanical issues, grid cooling systems have been included for ensuring reliable operation. This paper focuses on the thermo-hydraulic and thermo-mechanical design of the grids. Finite element calculations have been carried out to analyse the temperature and deformation of the grids under heat loads using the fluid dynamics code CFX. Based on these results, the cooling circuit design and cooling parameters are optimised to satisfy the grid requirements.

  19. In Situ Monitoring of Temperature inside Lithium-Ion Batteries by Flexible Micro Temperature Sensors

    Directory of Open Access Journals (Sweden)

    Pei-Chi Chen

    2011-10-01

    Full Text Available Lithium-ion secondary batteries are commonly used in electric vehicles, smart phones, personal digital assistants (PDA, notebooks and electric cars. These lithium-ion secondary batteries must charge and discharge rapidly, causing the interior temperature to rise quickly, raising a safety issue. Over-charging results in an unstable voltage and current, causing potential safety problems, such as thermal runaways and explosions. Thus, a micro flexible temperature sensor for the in in-situ monitoring of temperature inside a lithium-ion secondary battery must be developed. In this work, flexible micro temperature sensors were integrated into a lithium-ion secondary battery using the micro-electro-mechanical systems (MEMS process for monitoring temperature in situ.

  20. The Brookhaven National Laboratory electron beam ion source for RHIC.

    Science.gov (United States)

    Alessi, J G; Barton, D; Beebe, E; Bellavia, S; Gould, O; Kponou, A; Lambiase, R; Lockey, R; McNerney, A; Mapes, M; Marneris, Y; Okamura, M; Phillips, D; Pikin, A I; Raparia, D; Ritter, J; Snydstrup, L; Theisen, C; Wilinski, M

    2010-02-01

    As part of a new heavy ion preinjector that will supply beams for the Relativistic Heavy Ion Collider and the National Aeronautics and Space Administration Space Radiation Laboratory, construction of a new electron beam ion source (EBIS) is now being completed. This source, based on the successful prototype Brookhaven National Laboratory Test EBIS, is designed to produce milliampere level currents of all ion species, with q/m=(1/6)-(1/2). Among the major components of this source are a 5 T, 2-m-long, 204 mm diameter warm bore superconducting solenoid, an electron gun designed to operate at a nominal current of 10 A, and an electron collector designed to dissipate approximately 300 kW of peak power. Careful attention has been paid to the design of the vacuum system, since a pressure of 10(-10) Torr is required in the trap region. The source includes several differential pumping stages, the trap can be baked to 400 C, and there are non-evaporable getter strips in the trap region. Power supplies include a 15 A, 15 kV electron collector power supply, and fast switchable power supplies for most of the 16 electrodes used for varying the trap potential distribution for ion injection, confinement, and extraction. The EBIS source and all EBIS power supplies sit on an isolated platform, which is pulsed up to a maximum of 100 kV during ion extraction. The EBIS is now fully assembled, and operation will be beginning following final vacuum and power supply tests. Details of the EBIS components are presented.

  1. Low-temperature Conductivity Detection for Ultrasensitive Ion Chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Eom, Jiwon; Lee, Dong Soo [Yonsei University, Seoul (Korea, Republic of)

    2016-03-15

    The effects of conductivity detection temperature on calibration sensitivity and linearity in suppressed ion chromatography using hydronium or hydroxide eluent were investigated. Theoretical calibration curves for lithium and nitrate ions at 0-35 .deg. C were calculated and compared with experimental data. As the detection temperature was lowered, both sensitivity and linearity of calibration at low concentrations were improved due to the reduced interference by water autoionization equilibrium; 4.3- and 1.3-fold increases in linear regression slopes were observed in the 0-1 μmol/L range when the temperature was lowered from 35 to 5 .deg. C for lithium and nitrate,respectively, along with significant increases in the correlation coefficient. Any remaining water autoionization effect was near completely removed by using eluents contaminated with rubidium or bromide ion at 0.1 μmol/L.

  2. Development of a laser ion source for production of high-intensity heavy-ion beams

    Science.gov (United States)

    Kashiwagi, H.; Yamada, K.; Kurashima, S.

    2017-09-01

    A laser ion source has been developed as a high-intensity source for the ion implanter and the single pulsed beam of the azimuthally varying field cyclotron at TIARA. Highly charged beams of C5+ and C6+ ions and low-charged beams of heavy ions such as C, Al, Ti, Cu, Au, and Pt are required for the single-pulse acceleration in the cyclotron and for the ion implanter, respectively. In the vacuum chamber of the ion source, a target holder on a three-dimensional linear-motion stage provides a fresh surface for each laser shot. A large-sized target with a maximum size of 300 mm × 135 mm is mounted on the holder for long-term operation. The ion current (ion charge flux) in the laser-produced plasma is measured by a Faraday cup and time-of-flight spectra of each charge state are measured using a 90° cylindrical electrostatic analyzer just behind the Faraday cup. Carbon-plasma-generation experiments indicate that the source produces intense high- and low-charged pulsed ion beams. At a laser energy of 483 mJ (2.3 × 1013 W/cm2), average C6+ current of 13 mA and average C5+ current of 23 mA were obtained over the required time duration for single-pulse acceleration in the cyclotron (49 ns for C6+ and 80 ns for C5+). Furthermore, at 45 mJ (2.1 × 1012 W/cm2), an average C2+ current of 1.6 mA over 0.88 μs is obtained.

  3. Enhanced Physicochemical and Biological Properties of Ion-Implanted Titanium Using Electron Cyclotron Resonance Ion Sources

    Directory of Open Access Journals (Sweden)

    Csaba Hegedűs

    2016-01-01

    Full Text Available The surface properties of metallic implants play an important role in their clinical success. Improving upon the inherent shortcomings of Ti implants, such as poor bioactivity, is imperative for achieving clinical use. In this study, we have developed a Ti implant modified with Ca or dual Ca + Si ions on the surface using an electron cyclotron resonance ion source (ECRIS. The physicochemical and biological properties of ion-implanted Ti surfaces were analyzed using various analytical techniques, such as surface analyses, potentiodynamic polarization and cell culture. Experimental results indicated that a rough morphology was observed on the Ti substrate surface modified by ECRIS plasma ions. The in vitro electrochemical measurement results also indicated that the Ca + Si ion-implanted surface had a more beneficial and desired behavior than the pristine Ti substrate. Compared to the pristine Ti substrate, all ion-implanted samples had a lower hemolysis ratio. MG63 cells cultured on the high Ca and dual Ca + Si ion-implanted surfaces revealed significantly greater cell viability in comparison to the pristine Ti substrate. In conclusion, surface modification by electron cyclotron resonance Ca and Si ion sources could be an effective method for Ti implants.

  4. Commissioning of the superconducting ECR ion source VENUS

    Energy Technology Data Exchange (ETDEWEB)

    Leitner, Daniela; Abbott, Steve R.; Dwinell, Roger D.; Leitner, Matthaeus; Taylor, Clyde; Lyneis, Claude M.

    2003-05-15

    VENUS (Versatile ECR ion source for NUclear Science) is a next generation superconducting ECR ion source, designed to produce high current, high charge state ions for the 88-Inch Cyclotron at the Lawrence Berkeley National Laboratory. VENUS also serves as the prototype ion source for the RIA (Rare Isotope Accelerator) front end. The magnetic confinement configuration consists of three superconducting axial coils and six superconducting radial coils in a sextupole configuration. The nominal design fields of the axial magnets are 4T at injection and 3T at extraction; the nominal radial design field strength at the plasma chamber wall is 2T, making VENUS the world most powerful ECR plasma confinement structure. The magnetic field strength has been designed for optimum operation at 28 GHz. The four-year VENUS project has recently achieved two major milestones: The first plasma was ignited in June, the first mass-analyzed high charge state ion beam was extracted in September of 2002. The pa per describes the ongoing commissioning. Initial results including first emittance measurements are presented.

  5. An inductively heated hot cavity catcher laser ion source

    CERN Document Server

    Reponen, M; Pohjalainen, I; Rothe, S; Savonen, M; Sonnenschein, V; Voss, A

    2015-01-01

    An inductively heated hot cavity catcher has been constructed for the production of low-energy ion beams of exotic, neutron-deficient Agisotopes. A proof-of-principle experiment has been realized by implanting primary 107Ag21+ ions from a heavy-ion cyclotron into a graphite catcher. A variable-thickness nickel foil was used to degrade the energy of the primary beam in order to mimic the implantation depth expected from the heavy-ion fusion-evaporation recoils of N = Z94Ag. Following implantation, the silver atoms diffused out of the graphite and effused into the catcher cavity and transfer tube, where they were resonantly laser ionized using a three-step excitation and ionization scheme. Following mass separation, the ions were identified by scanning the frequency of the first resonant excitation step while recording the ion count rate. Ion release time profiles were measured for different implantation depths and cavity temperatures with the mean delay time varying from 10 to 600 ms. In addition, the diffusio...

  6. Beamlet interaction in multi-aperture negative ion source

    Energy Technology Data Exchange (ETDEWEB)

    Fujiwara, Yukio; Hanada, Masaya; Kawai, Kenichi; Kitagawa, Tadashi; Miyamoto, Kenji; Okumura, Yoshikazu; Watanabe, Kazuhiro [Japan Atomic Energy Research Inst., Naka, Ibaraki (Japan). Naka Fusion Research Establishment

    1999-02-01

    Beamlet interaction, which may deteriorate beam convergence, was studied in a high-current negative ion beam composed of multiple beamlets. Experimental results demonstrated that a deflection angle of beamlets at the edge of a beam was larger than that at the center of a beam, because of space charge effect. The deflection angle was independent of the beam energy ranging from 86 keV to 178 keV at the same perveance. Effect of electrons accompanying negative ions was confirmed to be negligible. It was shown that repulsive force due to space charge effect was inversely proportional to the square of distance. The maximum deflection angle of a large negative ion source for the JT-60 Negative ion-NBI system was estimated to be about 6.6 mrad based on the obtained results. Shaping of a grid was proposed to compensate the beamlet interaction. Beam orbit simulations indicated the effectiveness of the shaping. (author)

  7. Estimation of Sputtering Damages on a Magnetron H- Ion Source Induced by Cs+ and H+ Ions

    CERN Document Server

    Pereira, H; Alessi, J; Kalvas, t

    2013-01-01

    An H− ion source is being developed for CERN’s Linac4 accelerator. A beam current requirement of 80 mA and a reliability above 99% during 1 year with 3 month uninterrupted operation periods are mandatory. To design a low-maintenance long life-time source, it is important to investigate and understand the wear mechanisms. A cesiated plasma discharge ion source, such as the BNL magnetron source, is a good candidate for the Linac4 ion source. However, in the magnetron source operated at BNL, the removal of material from the molybdenum cathode and the stainless steel anode cover plate surfaces is visible after extended operation periods. The observed sputtering traces are shown to result from cesium vapors and hydrogen gas ionized in the extraction region and subsequently accelerated by the extraction field. This paper presents a quantitative estimate of the ionization of cesium and hydrogen by the electron and H− beams in the extraction region of BNL’s magnetron ion source. The respective contributions o...

  8. Nanostructure operations by means of the liquid metal ion sources.

    Science.gov (United States)

    Gasanov, I S; Gurbanov, I I

    2012-02-01

    Characteristics of a disperse phase of liquid metal ion source on the basis of various working substances are investigated. It is revealed that generation of the charged particles occurs in the threshold image and is simultaneously accompanied by excitation of capillary instability on a surface of the emitter. The majority of particles has the size about 2 nm (Sn) and a specific charge of 5 × 10(4) C∕kg. If the working liquid possesses high viscosity (Ni), generation of nanodroplets does not occur. Gold nanoparticles are used for deposition on a surface of quartz cantilevers with the purpose of increase in sensitivity of biosensors and on an external surface of carbon nanotubes for creation pressure sensors. By means of an ion source nanostructures can be etched on a flat surface of conductive materials without difficult ion optics.

  9. A LASER ION-SOURCE FOR ONLINE MASS SEPARATION

    NARCIS (Netherlands)

    VANDUPPEN, P; DENDOOVEN, P; HUYSE, M; VERMEEREN, L; QAMHIEH, ZN; SILVERANS, RE; VANDEWEERT, E

    1992-01-01

    A laser ion source based on resonance photo ionization in a gas cell is proposed. The gas cell, filled with helium, consists of a target chamber in which the recoil products are stopped and neutralized, and an ionization chamber where the atoms of interest are selectively ionized by the laser light.

  10. Compact Ion and Neutral Mass Spectrometer with Ion Drifts, Temperatures and Neutral Winds

    Science.gov (United States)

    Paschalidis, Nikolaos

    2016-07-01

    In situ measurements of atmospheric neutral and ion composition and density, temperatures, ion drifts and neutral winds, are in high demand to study the dynamics of the ionosphere-theremosphere-mesosphere system. This paper presents a compact Ion and Neutral Mass Spectrometer (INMS) with impended ion drifts and temperature, and neutral winds capability for in situ measurements of ions and neutrals H, He, N, O, N2, O2. The mass resolution M/dM is approximately 10 at an incoming energy range of 0-20eV. The goal is to resolve ion drifts in the range 0 to 3000m/sec with a resolution better than 50m/sec, and neutral winds in the range of 0 to 1000m/sec with similar resolution. For temperatures the goal is to cover a dynamic range of 0 to 5000K. The INMS is based on front end optics for ions and neutrals, pre acceleration, gated time of flight, top hat ESA, MCP detectors and compact electronics. The instrument is redundant for ions and neutrals with the ion and neutral sensor heads on opposite sides and with full electronics in the middle. The ion front end includes RPA for temperature scanning and neutral front end includes angular modulation and thermionic ionization and ion blocking grids. The electronics include fast electric gating, TOF electronics, TOF binning and C&DH digital electronics. The data package includes 400 mass bins each for ions and neutrals and key housekeeping data for instrument health and calibration. The data sampling can be commanded from 0.1 to 10 sec with 1sec nominal setting. The instrument has significant onboard storage capability and a data compression scheme. The mass spectrometer version of the instrument has been flown on the Exocube mission. The instrument occupied 1.5U volume, weighed only 560 g and required nominal power of 1.6W The ExoCube mission was designed to acquire global knowledge of in-situ densities of [H], [He], [O] and H+, He+, O+ in the upper ionosphere and lower exosphere in combination with incoherent scatter radar and

  11. Flashback and perspectives for the production of intense ion beams with ECR ion sources

    Science.gov (United States)

    Gammino, S.; Ciavola, G.; Consoli, F.; Barbarino, S.; Celona, L.; Mascali, D.

    2005-10-01

    There is a clear evidence that the combination of ability to produce intense beams of highly charged heavy ions and of reliability, stability and low emittance can be guaranteed only by an adequate design of electron cyclotron resonance ion sources (ECRIS). Following the roadmap defined by Geller's scaling laws (1987) and the high B-mode concept (1990), the evolution of ECRIS has been steady and it amounted to about one order of magnitude per decade, as for high charge state currents. A further increase is possible according to the standard model of ECR sources unless technological problems may limit it in the future. Some sources are in the commissioning or construction phase to get the milliampere level for highly charged heavy ions, and some limitations have been already found but the possibility to get a further step forward remains unchanged. This paper presents the flashbacks of previous relevant experiences, along with the perspectives for higher current production in the years after 2010.

  12. In Situ Monitoring of Temperature inside Lithium-Ion Batteries by Flexible Micro Temperature Sensors

    OpenAIRE

    Lee, Chi-Yuan; Lee, Shuo-Jen; Tang, Ming-Shao; Chen, Pei-Chi

    2011-01-01

    Lithium-ion secondary batteries are commonly used in electric vehicles, smart phones, personal digital assistants (PDA), notebooks and electric cars. These lithium-ion secondary batteries must charge and discharge rapidly, causing the interior temperature to rise quickly, raising a safety issue. Over-charging results in an unstable voltage and current, causing potential safety problems, such as thermal runaways and explosions. Thus, a micro flexible temperature sensor for the in in-situ monit...

  13. Subzero-Temperature Cathode for a Sodium-Ion Battery.

    Science.gov (United States)

    You, Ya; Yao, Hu-Rong; Xin, Sen; Yin, Ya-Xia; Zuo, Tong-Tong; Yang, Chun-Peng; Guo, Yu-Guo; Cui, Yi; Wan, Li-Jun; Goodenough, John B

    2016-09-01

    A subzero-temperature cathode material is obtained by nucleating cubic prussian blue crystals at inhomogeneities in carbon nanotubes. Due to fast ionic/electronic transport kinetics even at -25 °C, the cathode shows an outstanding low-temperature performance in terms of specific energy, high-rate capability, and cycle life, providing a practical sodium-ion battery powering an electric vehicle in frigid regions. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Power supply system for negative ion source at IPR

    Energy Technology Data Exchange (ETDEWEB)

    Gahlaut, Agrajit; Sonara, Jashwant; Parmar, K G; Soni, Jignesh; Bandyopadhyay, M; Singh, Mahendrajit; Bansal, Gourab; Pandya, Kaushal; Chakraborty, Arun, E-mail: agrajit@ipr.res.i [Institute for Plasma Research, Gandhinagar, Gujarat - 382428 (India)

    2010-02-01

    The first step in the Indian program on negative ion beams is the setting up of Negative ion Experimental Assembly - RF based, where 100 kW of RF power shall be coupled to a plasma source producing plasma of density {approx}5 x 10{sup 12} cm{sup -3}, from which {approx} 10 A of negative ion beam shall be produced and accelerated to 35 kV, through an electrostatic ion accelerator. The experimental system is modelled similar to the RF based negative ion source, BATMAN presently operating at IPP, Garching, Germany. The mechanical system for Negative Ion Source Assembly is close to the IPP source, remaining systems are designed and procured principally from indigenous sources, keeping the IPP configuration as a base line. High voltage (HV) and low voltage (LV) power supplies are two key constituents of the experimental setup. The HV power supplies for extraction and acceleration are rated for high voltage ({approx}15 to 35kV), and high current ({approx} 15 to 35A). Other attributes are, fast rate of voltage rise (< 5ms), good regulation (< {+-}1%), low ripple (< {+-}2%), isolation ({approx}50kV), low energy content (< 10J) and fast cut-off (< 100{mu}s). The low voltage (LV) supplies required for biasing and providing heating power to the Cesium oven and the plasma grids; have attributes of low ripple, high stability, fast and precise regulation, programmability and remote operation. These power supplies are also equipped with over-voltage, over-current and current limit (CC Mode) protections. Fault diagnostics, to distinguish abnormal rise in currents (breakdown faults) with over-currents is enabled using fast response breakdown and over-current protection scheme. To restrict the fault energy deposited on the ion source, specially designed snubbers are implemented in each (extraction and acceleration) high voltage path to swap the surge energy. Moreover, the monitoring status and control signals from these power supplies are required to be electrically ({approx} 50k

  15. First experiments with gasdynamic ion source in CW mode

    Energy Technology Data Exchange (ETDEWEB)

    Skalyga, V., E-mail: skalyga@ipfran.ru; Vodopyanov, A. [Institute of Applied Physics, Russian Academy of Sciences (IAP RAS), 46 Ul‘yanova St., Nizhny Novgorod 603950 (Russian Federation); Lobachevsky State University of Nizhny Novgorod (UNN), 23 Gagarina St., Nizhny Novgorod 603950 (Russian Federation); Izotov, I.; Golubev, S. [Institute of Applied Physics, Russian Academy of Sciences (IAP RAS), 46 Ul‘yanova St., Nizhny Novgorod 603950 (Russian Federation); Tarvainen, O. [Department of Physics, University of Jyvaskyla, P.O. Box 35 (YFL), 40500 Jyvaskyla (Finland)

    2016-02-15

    A new type of ECR ion source—a gasdynamic ECR ion source—has been recently developed at the Institute of Applied Physics. The main advantages of such device are extremely high ion beam current with a current density up to 600–700 emA/cm{sup 2} in combination with low emittance, i.e., normalized RMS emittance below 0.1 π mm mrad. Previous investigations were carried out in pulsed operation with 37.5 or 75 GHz gyrotron radiation with power up to 100 kW at SMIS 37 experimental facility. The present work demonstrates the first experience of operating the gasdynamic ECR ion source in CW mode. A test bench of SMIS 24 facility has been developed at IAP RAS. 24 GHz radiation of CW gyrotron was used for plasma heating in a magnetic trap with simple mirror configuration. Initial studies of plasma parameters were performed. Ion beams with pulsed and CW high voltage were successfully extracted from the CW discharge. Obtained experimental results demonstrate that all advantages of the gasdynamic source can be realized also in CW operation.

  16. Influence of temperature and ion concentration on sedimentation ...

    African Journals Online (AJOL)

    Physical and chemical variables of insoluble salts generally affect sedimentation characteristics of precipitates. In this research study, the effects of temperature and ion concentration on the sedimentation of tricalcium phosphate (TCP) and tristrontium phosphate (TSP) were studied. The focus was to determine the ...

  17. Effect of nonthermal ion distribution and dust temperature on ...

    Indian Academy of Sciences (India)

    Dust-acoustic solitary waves in unmagnetized dusty plasma whose constituents are iner- tial charged dust grains, Boltzmannian electrons and nonthermal ions have been investigated by taking into account finite dust temperature. The pseudopotential has been used to study solitary solution. The existence of solitary waves ...

  18. Measurement of Plasma Ion Temperature and Flow Velocity from ...

    Indian Academy of Sciences (India)

    Abstract. The distinction between Doppler broadening and Doppler shift has been analysed, the differences between Gaussian fitting and the distribution of chord-integral line shape have also been discussed. Local ion temperature and flow velocity have been derived from the chord-averaged emission line profile by a ...

  19. Electrolytes for Wide Operating Temperature Lithium-Ion Cells

    Science.gov (United States)

    Smart, Marshall C. (Inventor); Bugga, Ratnakumar V. (Inventor)

    2016-01-01

    Provided herein are electrolytes for lithium-ion electrochemical cells, electrochemical cells employing the electrolytes, methods of making the electrochemical cells and methods of using the electrochemical cells over a wide temperature range. Included are electrolyte compositions comprising a lithium salt, a cyclic carbonate, a non-cyclic carbonate, and a linear ester and optionally comprising one or more additives.

  20. Spherical dust acoustic solitary waves with two temperature ions

    CERN Document Server

    Eslami, Esmaeil

    2014-01-01

    The nonlinear dust acoustic waves in unmagnetized dusty plasma which consists of two temperature Boltzmann distributed ions and Boltzmann distributed electrons in spherical dimension investigated and obtained spherical Kadomtsev Petviashvili (SKP) equation and shown that the dust acoustic solitary wave can exist in the SKP equation.

  1. Effect of preparation temperature and ions doping on size ...

    African Journals Online (AJOL)

    Binary and quaternary amorphous nano powders are prepared by wet reduction method. Cobalt boride nano catalyst is synthesized at 10 and 60 ºC. Effect of preparation temperature on size and morphology was studied. Co-M-Zr-B (M: Cr, Mo and W) as quaternary catalysts are also prepared in order to studying ions ...

  2. Fundamental characteristics of liquid cluster ion source for surface modification

    Energy Technology Data Exchange (ETDEWEB)

    Takaoka, G.H. [Ion Beam Engineering Experimental Laboratory, Kyoto University, Nishikyo, Kyoto 615-8510 (Japan)]. E-mail: gtakaoka@kuee.kyoto-u.ac.jp; Noguchi, H. [Ion Beam Engineering Experimental Laboratory, Kyoto University, Nishikyo, Kyoto 615-8510 (Japan); Nakayama, K. [Ion Beam Engineering Experimental Laboratory, Kyoto University, Nishikyo, Kyoto 615-8510 (Japan); Hironaka, Y. [Ion Beam Engineering Experimental Laboratory, Kyoto University, Nishikyo, Kyoto 615-8510 (Japan); Kawashita, M. [Ion Beam Engineering Experimental Laboratory, Kyoto University, Nishikyo, Kyoto 615-8510 (Japan)

    2005-08-01

    We have developed a cluster ion source using liquid organic materials, which has several advantages for surface modification based on the different properties of liquid cluster ions. When vapors of liquid materials such as ethanol were ejected through a nozzle into a high-vacuum region, clusters were produced by an adiabatic expansion phenomenon. The clusters produced were ionized by an electron bombardment method, and the cluster ion current increased with increase of an electron current for ionization. In order to achieve the effective transport of cluster ion beams, a unipotential or einzel lens was used. The current density was much larger than that without using the lens. Furthermore, the beam diameter could be controlled by adjusting the lens voltage, and it was changed between 5 mm and 20 mm. In addition, several kinds of substrates such as Si, SiO{sub 2}, PC substrates were irradiated at different acceleration voltages with ethanol cluster ion beams, and chemical and physical sputtering with a high sputtering yield was achieved. The sputtered surfaces were very smooth at an atomic level. The liquid cluster ion beams have a high potential for surface etching with the atomic level flatness, which is not obtained by a conventional wet process.

  3. A CW radiofrequency ion source for production of negative hydrogen ion beams for cyclotrons

    Energy Technology Data Exchange (ETDEWEB)

    Kalvas, T.; Tarvainen, O.; Komppula, J.; Koivisto, H.; Tuunanen, J. [University of Jyväskylä, Department of Physics (Finland); Potkins, D.; Stewart, T.; Dehnel, M. P. [D-Pace, Inc., Nelson, B.C. Canada (Canada)

    2015-04-08

    A CW 13.56 MHz radiofrequency-driven ion source RADIS for production of H{sup −} and D{sup −} beams is under development for replacing the filament-driven ion source of the MCC30/15 cyclotron. The RF ion source has a 16-pole multicusp plasma chamber, an electromagnet-based magnetic filter and an external planar spiral RF antenna behind an AlN window. The extraction is a 5-electrode system with an adjustable puller electrode voltage for optimizing the beam formation, a water-cooled electron dump electrode and an accelerating einzel lens. At 2650 W of RF power, the source produces 1 mA of H{sup −} (2.6 mA/cm{sup 2}), which is the intensity needed at injection for production of 200 µA H{sup +} with the filament-driven ion source. A simple pepperpot device has been developed for characterizing the beam emittance. Plans for improving the power efficiency with the use of a new permanent magnet front plate is discussed.

  4. Detailed beam and plasma measurements on the vessel for extraction and source plasma analyses (VESPA) Penning H- ion source

    Science.gov (United States)

    Lawrie, S. R.; Faircloth, D. C.; Letchford, A. P.; Whitehead, M. O.; Wood, T.

    2016-02-01

    A vessel for extraction and source plasma analyses (VESPA) is operational at the Rutherford Appleton Laboratory (RAL). This project supports and guides the overall ion source R&D effort for the ISIS spallation neutron and muon facility at RAL. The VESPA produces 100 mA of pulsed H- beam, but perveance scans indicate that the source is production-limited at extraction voltages above 12 kV unless the arc current is increased. A high resolution optical monochromator is used to measure plasma properties using argon as a diagnostic gas. The atomic hydrogen temperature increases linearly with arc current, up to 2.8 eV for 50 A; whereas the electron temperature has a slight linear decrease toward 2.2 eV. The gas density is 1021 m-3, whilst the electron density is two orders of magnitude lower. Densities follow square root relationships with arc current, with gas density decreasing whilst electron (and hence ion) density increases. Stopping and range of ions in matter calculations prove that operating a high current arc with an argon admixture is extremely difficult because cathode-coated cesium is heavily sputtered by argon.

  5. In-ESI source hydrogen/deuterium exchange of carbohydrate ions.

    Science.gov (United States)

    Kostyukevich, Yury; Kononikhin, Alexey; Popov, Igor; Nikolaev, Eugene

    2014-03-04

    We present the investigation of hydrogen/deuterium (H/D) exchange of carbohydrates ions occurring in the electrospray ion source. The shape of the deuterium distribution was observed to be considerably dependent on the temperature of the ion transfer tube and the solvent used. If deuterated alcohol (EtOD or MeOD) or D2O/deuterated alcohol is used as an electrospray solvent, then for high temperatures (>350 °C), intensive back exchange is observed, resulting in ∼30% depth of the deuterium exchange. At low temperatures (deuterium exchange is ∼70%. In the intermediate temperature region (∼250 °C), the deuterium distribution is unusually wide for methanol and bimodal for ethanol. The addition of 1% formic acid results in low (∼30%) depth of the deuterium exchange for any temperature in the operating region. The bimodal distribution for the ethanol can be possibly explained by the presence of differently folded gas-phase ions of carbohydrates.

  6. Status of GISELE: a resonant ionization laser ion source for the production of radioactive ions at GANIL

    Energy Technology Data Exchange (ETDEWEB)

    Sjoedin, A. M., E-mail: sjodin@ganil.fr; Lecesne, N.; Bajeat, O. [GANIL (France); Kron, T. [Johannes Gutenberg-Universitaet Mainz (Germany); Lassen, J. [TRIUMF (Canada); Blanc, F. Le [IPHC (France); Leroy, R.; Maunoury, L.; Osmond, B. [GANIL (France); Raeder, S. [Johannes Gutenberg-Universitaet Mainz (Germany); Rothe, S. [CERN, CERN ' European Organization for Nuclear Research' (Switzerland); Sonnenshein, V. [University of Jyvaeskylae (Finland); Wendt, K. [Johannes Gutenberg-Universitaet Mainz (Germany)

    2013-04-15

    Laser ion sources are in use extensively to ionize the nuclear reaction products at many on-line radioactive ion beam facilities. They have proven to be reliable and to combine good production efficiencies with chemical selectivity. A Laser ion source is currently under development for the SPIRAL2 project at GANIL. A status update of this project called GISELE is presented.

  7. Status and Operation of the Linac4 Ion Source Prototypes

    CERN Document Server

    Lettry, J; Andersson, P; Bertolo, S; Butterworth, A; Coutron, Y; Dallocchio, A; Chaudet, E; Gil-Flores, J; Guida, R; Hansen, J; Hatayama, A; Koszar, I; Mahner, E; Mastrostefano, C; Mathot, S; Mattei, S; Midttun, O; Moyret, P; Nisbet, D; Nishida, K; O’Neil, M; Ohta, M; Paoluzzi, M; Pasquino, C; Pereira, H; Rochez, J; Sanchez Alvarez, J; Sanchez Arias, J; Scrivens, R; Shibata, T; Steyaert, D; Thaus, N; Yamamoto, T

    2014-01-01

    CERN’s Linac4 45 kV H- ion sources prototypes are installed at a dedicated ion source test stand and in the Linac4 tunnel. The operation of the pulsed hydrogen injection, RF sustained plasma and pulsed high voltages are described. The first experimental results of two prototypes relying on 2MHz RF- plasma heating are presented. The plasma is ignited via capacitive coupling, and sustained by inductive coupling. The light emitted from the plasma is collected by viewports pointing to the plasma chamber wall in the middle of the RF solenoid and to the plasma chamber axis. Preliminary measurements of optical emission spectroscopy and photometry of the plasma have been performed. The design of a cesiated ion source is presented. The volume source has produced a 45 keV H- beam of 16-22 mA which has successfully been used for the commissioning of the Low Energy Beam Transport (LEBT), Radio Frequency Quadrupole (RFQ) accelerator and chopper of Linac4.

  8. Status report of the ECR ion sources at the KVI

    CERN Document Server

    Drentje, A G; Kremers, H R; Meyer, D; Mulder, J; Sijbring, J

    1999-01-01

    At the moment three ECR ion sources are in operation at the KVI. One of these is being used as the ionizer section of the polarized ion (protons and deuterons) source POLIS; it runs at 2.5 GHz. In this paper the emphasis will be on the other two ECRISs, both being used for the production of highly charged ions. ECRIS3 is connected to the AGOR super-conducting Cyclotron. Beams of 12, 13C6+, 14N7+, 15N5+, 16O6+, 8+, 36Ar11+, 12+, 14+, 40Ar8+ and 3He2+, 4He2+ have been produced at various source voltages (16 - 29 kV), corresponding to a range of beam energies for experiments. The source is operating satisfactorily with sufficiently high beam intensities. Gas mixing is important for the high charge states of argon, where the best results have been obtained with 18O as a mixing gas. Since the AGOR cyclotron is used for the larger fraction of available beam time with (polarized) protons, the ECRIS3 set up is quite often available for test runs. ECRIS4 is connected to the five experimental set-ups of the Atomic Phys...

  9. Target-ion source unit ionization efficiency measurement by method of stable ion beam implantation

    CERN Document Server

    Panteleev, V.N; Fedorov, D.V; Moroz, F.V; Orlov, S.Yu; Volkov, Yu.M

    The ionization efficiency is one of the most important parameters of an on-line used target-ion source system exploited for production of exotic radioactive beams. The ionization efficiency value determination as a characteristic of a target-ion source unit in the stage of its normalizing before on-line use is a very important step in the course of the preparation for an on-line experiment. At the IRIS facility (Petersburg Nuclear Physics Institute, Gatchina) a reliable and rather precise method of the target-ion source unit ionization efficiency measurement by the method of stable beam implantation has been developed. The method worked out exploits an off-line mass-separator for the implantation of the ion beams of selected stable isotopes of different elements into a tantalum foil placed inside the Faraday cup in the focal plane of the mass-separator. The amount of implanted ions has been measured with a high accuracy by the current integrator connected to the Faraday cup. After the implantation of needed a...

  10. High temperature annealing studies of strontium ion implanted glassy carbon

    Energy Technology Data Exchange (ETDEWEB)

    Odutemowo, O.S., E-mail: u12052613@tuks.co.za [Department of Physics, University of Pretoria, Pretoria 0002 (South Africa); Malherbe, J.B.; Prinsloo, L.; Langa, D.F. [Department of Physics, University of Pretoria, Pretoria 0002 (South Africa); Wendler, E. [Institut für Festkörperphysik, Friedrich-Schiller University, Jena (Germany)

    2016-03-15

    Glassy carbon samples were implanted with 200 keV strontium ions to a fluence of 2 × 10{sup 16} ions/cm{sup 2} at room temperature. Analysis with Raman spectroscopy showed that ion bombardment amorphises the glassy carbon structure. Partial recovery of the glassy carbon structure was achieved after the implanted sample was vacuum annealed at 900 °C for 1 h. Annealing the strontium ion bombarded sample at 2000 °C for 5 h resulted in recovery of the glassy carbon substrate with the intensity of the D peak becoming lower than that of the pristine glassy carbon. Rutherford backscattering spectroscopy (RBS) showed that the implanted strontium diffused towards the surface of the glassy carbon after annealing the sample at 900 °C. This diffusion was also accompanied by loss of the implanted strontium. Comparison between the as-implanted and 900 °C depth profiles showed that less than 30% of the strontium was retained in the glassy carbon after heat treatment at 900 °C. The RBS profile after annealing at 2000 °C indicated that no strontium ions were retained after heat treatment at this temperature.

  11. Proceedings of the 10th international workshop on ECR ion sources

    Energy Technology Data Exchange (ETDEWEB)

    Meyer, F W; Kirkpatrick, M I [eds.

    1991-01-01

    This report contains papers on the following topics: Recent Developments and Future Projects on ECR Ion Sources; Operation of the New KVI ECR Ion Source at 10 GHz; Operational Experience and Status of the INS SF-ECR Ion Source; Results of the New ECR4'' 14.5 GHz ECRIS; Preliminary Performance of the AECR; Experimental Study of the Parallel and Perpendicular Particle Losses from an ECRIS Plasma; Plasma Instability in Electron Cyclotron Resonance Heated Ion Sources; The Hyperbolic Energy Analyzer; Status of ECR Source Development; The New 10 GHz CAPRICE Source; First Operation of the Texas A M ECR Ion Source; Recent Developments of the RIKEN ECR Ion Sources; The 14 GHz CAPRICE Source; Characteristics and Potential Applications of an ORNL Microwave ECR Multicusp Plasma Ion Source; ECRIPAC: The Production and Acceleration of Multiply Charged Ions Using an ECR Plasma; ECR Source for the HHIRF Tandem Accelerator; Feasibility Studies for an ECR-Generated Plasma Stripper; Production of Ion Beams by using the ECR Plasmas Cathode; A Single Stage ECR Source for Efficient Production of Radioactive Ion Beams; The Single Staged ECR Source at the TRIUMF Isotope Separator TISOL; The Continuous Wave, Optically Pumped H{sup {minus}} Source; The H{sup +} ECR Source for the LAMPF Optically Pumped Polarized Ion Source; Present Status of the Warsaw CUSP ECR Ion Source; An ECR Source for Negative Ion Production; GYRAC-D: A Device for a 200 keV ECR Plasma Production and Accumulation; Status Report of the 14.4 GHZ ECR in Legnaro; Status of JYFL-ECRIS; Report on the Uppsala ECRIS Facility and Its Planned Use for Atomic Physics; A 10 GHz ECR Ion Source for Ion-Electron and Ion-Atom Collision Studies; and Status of the ORNL ECR Source Facility for Multicharged Ion Collision Research.

  12. Effect of Coulomb collision on the negative ion extraction mechanism in negative ion sources

    Energy Technology Data Exchange (ETDEWEB)

    Goto, I., E-mail: goto@ppl.appi.keio.ac.jp; Nishioka, S.; Abe, S.; Hatayama, A. [Graduate School of Science and Technology, Keio University, 3-14-1 Hiyoshi, Kohoku-ku, Yokohama 223-8522 (Japan); Miyamoto, K. [Naruto University of Education, 748 Nakashima, Takashima, Naruto-cho, Naruto-shi, Tokushima 772-8502 (Japan); Mattei, S.; Lettry, J. [CERN, 1211 Geneva 23 (Switzerland)

    2016-02-15

    To improve the H{sup −} ion beam optics, it is necessary to understand the energy relaxation process of surface produced H{sup −} ions in the extraction region of Cs seeded H{sup −} ion sources. Coulomb collisions of charged particles have been introduced to the 2D3V-PIC (two dimension in real space and three dimension in velocity space particle-in-cell) model for the H{sup −} extraction by using the binary collision model. Due to Coulomb collision, the lower energy part of the ion energy distribution function of H{sup −} ions has been greatly increased. The mean kinetic energy of the surface produced H{sup −} ions has been reduced to 0.65 eV from 1.5 eV. It has been suggested that the beam optics of the extracted H{sup −} ion beam is strongly affected by the energy relaxation process due to Coulomb collision.

  13. Energetic metallic ion implantation in polymers via cost-effective laser-driven ion source

    Science.gov (United States)

    Tahir, Muhammad Bilal; Rafique, M. Shahid; Ahmed, Rabia; Rafique, M.; Iqbal, Tahir; Hasan, Ali

    2017-07-01

    This research work reports the ions emission from the plasma generated by Nd:YAG laser having wavelength 1.064 μm, power 1.1 MW, pulse energy 10 mJ and intensity 1011 W/cm2 irradiated at 70° with respect to the target normal to the ions. These ions were accelerated through a home-made extraction assembly by means of a high voltage DC power supply. The energy of these ions were measured using Thomson parabola technique which utilizes Solid State Nuclear Track Detector (CR-39) and confirmed by Faraday cup as well that exploits a well-known technique known as time of flight. Interestingly, a significant increase in energy (from 490 to 730 keV) was observed with a discrete increase in acceleration potential from 0 to 18 kV. Polyethylene terephthalate (PET) and polypropylene were exposed to this recently developed ion source facility, to authenticate the reliability of this facility. The surface of the polymer is affected when energy of the irradiated ion is increased, which is evident from the optical micrographs. An increase in electrical conductivity was also observed with the increase in ion energy.

  14. ELECTRON BEAM ION SOURCE PREINJECTOR PROJECT (EBIS) CONCEPTUAL DESIGN REPORT.

    Energy Technology Data Exchange (ETDEWEB)

    ALESSI, J.; BARTON, D.; BEEBE, E.; GASSNER, D.; ET AL.

    2005-02-28

    This report describes a new heavy ion pre-injector for the Relativistic Heavy Ion Collider (RHIC) based on a high charge state Electron Beam Ion Source (EBIS), a Radio Frequency Quadrupole (RFQ) accelerator, and a short Linac. The highly successful development of an EBIS at BNL now makes it possible to replace the present pre-injector that is based on an electrostatic Tandem with a reliable, low maintenance Linac-based pre-injector. Linac-based pre-injectors are presently used at most accelerator and collider facilities with the exception of RHIC, where the required gold beam intensities could only be met with a Tandem until the recent EBIS development. EBIS produces high charge state ions directly, eliminating the need for the two stripping foils presently used with the Tandem. Unstable stripping efficiencies of these foils are a significant source of luminosity degradation in RHIC. The high reliability and flexibility of the new Linac-based pre-injector will lead to increased integrated luminosity at RHIC and is an essential component for the long-term success of the RHIC facility. This new pre-injector, based on an EBIS, also has the potential for significant future intensity increases and can produce heavy ion beams of all species including uranium beams and, as part of a future upgrade, might also be used to produce polarized {sup 3}He beams. These capabilities will be critical to the future luminosity upgrades and electron-ion collisions in RHIC. The new RFQ and Linac that are used to accelerate beams from the EBIS to an energy sufficient for injection into the Booster are both very similar to existing devices already in operation at other facilities. Injection into the Booster will occur at the same location as the existing injection from the Tandem.

  15. ELECTRON BEAM ION SOURCE PREINJECTOR PROJECT (EBIS) CONCEPTUAL DESIGN REPORT.

    Energy Technology Data Exchange (ETDEWEB)

    ALESSI, J.; BARTON, D.; BEEBE, E.; GASSNER, D.; GRANDINETTI, R.; HSEUH, H.; JAVIDFAR, A.; KPONOU, A.; LAMBIASE, R.; LESSARD, E.; LOCKEY, R.; LODESTRO, V.; MAPES, M.; MIRABELLA, D.; NEHRING, T.; OERTER, B.; PENDZICK, A.; PIKIN, A.; RAPARIA, D.; RITTER, J.; ROSER, T.; RUSSO, T.; SNYDSTRUP, L.; WILINSKI, M.; ZALTSMAN, A.; ZHANG, S.

    2005-09-01

    This report describes a new heavy ion pre-injector for the Relativistic Heavy Ion Collider (RHIC) based on a high charge state Electron Beam Ion Source (EBIS), a Radio Frequency Quadrupole (RFQ) accelerator, and a short Linear accelerator (Linac). The highly successful development of an EBIS at Brookhaven National Laboratory (BNL) now makes it possible to replace the present pre-injector that is based on an electrostatic Tandem with a reliable, low maintenance Linac-based pre-injector. Linac-based preinjectors are presently used at most accelerator and collider facilities with the exception of RHIC, where the required gold beam intensities could only be met with a Tandem until the recent EBIS development. EBIS produces high charge state ions directly, eliminating the need for the two stripping foils presently used with the Tandem. Unstable stripping efficiencies of these foils are a significant source of luminosity degradation in RHIC. The high reliability and flexibility of the new Linac-based pre-injector will lead to increased integrated luminosity at RHIC and is an essential component for the long-term success of the RHIC facility. This new pre-injector, based on an EBIS, also has the potential for significant future intensity increases and can produce heavy ion beams of all species including uranium beams and, as part of a future upgrade, might also be used to produce polarized {sup 3}He beams. These capabilities will be critical to the future luminosity upgrades and electron-ion collisions in RHIC. The proposed pre-injector system would also provide for a major enhancement in capability for the NASA Space Radiation Laboratory (NSRL), which utilizes heavy-ion beams from the RHIC complex. EBIS would allow for the acceleration of all important ion species for the NASA radiobiology program, such as, helium, argon, and neon which are unavailable with the present Tandem injector. In addition, the new system would allow for very rapid switching of ion species for

  16. Spectroscopic applications of the ISOLDE laser ion source

    CERN Document Server

    Sebastian, V; Fedosseev, V; Georg, U; Huber, G; Jading, Y; Jonsson, O; Köster, U; Koizumi, M; Kratz, K L; Kugler, E; Lettry, Jacques; Mishin, V I; Ravn, H L; Tamburella, C; Wöhr, A

    1998-01-01

    At the ISOLDE facility radioactive ion beams are produced via proton induced reactions in a target which is connected to a laser ion source. For beryllium a two step excitation scheme with laser light at wavelengths of lambda =235 nm and lambda =297 nm has been developed. Efficient laser ionization of beryllium was achieved with a new optical set-up using frequency tripling with two non-linear BBO crystals to generate laser light in the ultraviolet for the first excitation step. The second step was optimized to reach the 2p/sup 2 1/S/sub 0/ autoionizing state for high ionization efficiency. The isotope shift of /sup 7,9,10,11,12,14/Ba could be measured by tuning the wavelength of the first step. The laser ion source has also been used for the preparation of neutron-rich silver ion beams. Tuning the laser frequency of the first step it was possible to ionize selectively low- and high spin isomers of silver isotopes via the hyperfine structure. In both cases it was demonstrated that laser spectroscopy of exotic...

  17. Abrupt variation in ion current with biased disk voltage in the electron cyclotron resonance ion source

    NARCIS (Netherlands)

    Taki, GS; Sarma, PR; Chakraborty, DK; Lhandari, RK; Ray, PK; Drentje, AG; Bhandari, R.K.

    The performance of the biased disk in the 6.4 GHz electron cyclotron resonance ion source at VECC, Kolkata was studied at a pressure of similar to 1 X 10(-7) Torr. We observed an abrupt variation of beam current with bias voltage. For low negative bias voltages (from 0 to -5 V) the beam current

  18. Status report of the JYFL-ECR ion sources

    CERN Document Server

    Ärje, J; Seppälä, R; Hyvönen, H; Liukkonen, E; Heikkinen, P; Nieminen, V; Ranttila, K; Hänninen, V; Lassila, A; Pakarinen, J; Koivisto, H; Xie, Z Q

    1999-01-01

    "Ion beam cocktails" are mixtures of ions with near-identical charge-to-mass ratios. In conjunction with the JYFL-ECRIS, the K130-cyclotron acts as a mass analyzer: the switch from one ion to another within the same cocktail is simple and fast. In the case of the first ion beam cocktail, the oxygen and argon gases were mixed into the gas feed line. At the same time the magnesium and iron ion beams were produced using the MIVOC method. Magnesocene and ferrocene compounds were both mixed into the MIVOC chamber. This capability is especially useful in the study of single event effects (SEE) in space electronics. All gaseous elements from H to Xe can be produced. The non-gaseous elements produced so far are C, Mg, Al, Si, S, Ca, Ti, Cr, Fe, Co, Ni, Cu, Zn and Ge. A major technical modification since the construction (in 1990) of the JYFL-ECRIS was made in January 98: a negatively biased disc replaces now the first plasma stage. After a couple of months experience with the modified source the change was found to b...

  19. Commissioning of the LINAC4 Ion Source Transverse Emittance Meter

    CERN Document Server

    Bravin, E; Dutriat, C; Lokhovitsky, A; Raich, U; Roncarolo, F; Scrivens, R; Zorin, E

    2010-01-01

    LINAC4 is the first step in the upgrade of the injector chain for the LHC, and will accelerate H- ions from 45 keV to 160 MeV. Currently the ion source is installed in a test setup and its commissioning started at the end of 2009. A slit-grid system is used to measure the transverse emittance of the beam at the exit of the source. The results of the measurements have been compared with analytical and numerical predictions of the performance of the emittance meter, addressing the system resolution, accuracy and sensitivity. The outcome of this analysis has been used to improve the design of a new slit-grid system foreseen for the commissioning of LINAC 4 at higher energy locations.

  20. Autopilot regulation for the Linac4 H- ion source

    Science.gov (United States)

    Voulgarakis, G.; Lettry, J.; Mattei, S.; Lefort, B.; Costa, V. J. Correia

    2017-08-01

    Linac4 is a 160 MeV H- linear accelerator part of the upgrade of the LHC injector chain. Its cesiated surface H- source is designed to provide a beam intensity of 40-50mA. It is operated with periodical Cs-injection at typically 30 days intervals [1] and this implies that the beam parameters will slowly evolve during operation. Autopilot is a control software package extending CERN developed Inspector framework. The aim of Autopilot is to automatize the mandatory optimization and cesiation processes and to derive performance indicators, thus keeping human intervention minimal. Autopilot has been developed by capitalizing on the experience from manually operating the source. It comprises various algorithms running in real-time, which have been devised to: • Optimize the ion source performance by regulation of H2 injection, RF power and frequency. • Describe the performance of the source with performance indicators, which can be easily understood by operators. • Identify failures, try to recover the nominal operation and send warning in case of deviation from nominal operation. • Make the performance indicators remotely available through Web pages.Autopilot is at the same level of hierarchy as an operator, in the CERN infrastructure. This allows the combination of all ion source devices, providing the required flexibility. Autopilot is executed in a dedicated server, ensuring unique and centralized control, yet allowing multiple operators to interact at runtime, always coordinating between them. Autopilot aims at flexibility, adaptability, portability and scalability, and can be extended to other components of CERN's accelerators. In this paper, a detailed description of the Autopilot algorithms is presented, along with first results of operating the Linac4 H- Ion Source with Autopilot.

  1. Blurring the boundaries between ion sources: The application of the RILIS inside a FEBIAD type ion source at ISOLDE

    Energy Technology Data Exchange (ETDEWEB)

    Day Goodacre, T., E-mail: thomas.day.goodacre@cern.ch [CERN, CH-1211 Geneva 23 (Switzerland); School of Physics and Astronomy, The University of Manchester, Manchester M13 9PL (United Kingdom); Billowes, J. [School of Physics and Astronomy, The University of Manchester, Manchester M13 9PL (United Kingdom); Catherall, R. [CERN, CH-1211 Geneva 23 (Switzerland); Cocolios, T.E. [School of Physics and Astronomy, The University of Manchester, Manchester M13 9PL (United Kingdom); Crepieux, B. [CERN, CH-1211 Geneva 23 (Switzerland); Fedorov, D.V. [Petersburg Nuclear Physics Institute, 188350 Gatchina (Russian Federation); Fedosseev, V.N. [CERN, CH-1211 Geneva 23 (Switzerland); Gaffney, L.P. [KU Leuven, Instituut voor Kern- en Stralingsfysica, 3001 Leuven (Belgium); Giles, T.; Gottberg, A.; Lynch, K.M.; Marsh, B.A.; Mendonça, T.M. [CERN, CH-1211 Geneva 23 (Switzerland); Ramos, J.P. [CERN, CH-1211 Geneva 23 (Switzerland); Laboratory of Powder Technology, EPFL, CH-1015 Lausanne (Switzerland); Rossel, R.E. [CERN, CH-1211 Geneva 23 (Switzerland); Institut für Physik, Johannes Gutenberg Universität, D-55099 Mainz (Germany); Faculty of Design, Computer Science and Media, Hochschule RheinMain, 65197 Wiesbaden (Germany); Rothe, S. [CERN, CH-1211 Geneva 23 (Switzerland); Sels, S.; Sotty, C. [KU Leuven, Instituut voor Kern- en Stralingsfysica, 3001 Leuven (Belgium); Stora, T. [CERN, CH-1211 Geneva 23 (Switzerland); Van Beveren, C. [KU Leuven, Instituut voor Kern- en Stralingsfysica, 3001 Leuven (Belgium); and others

    2016-06-01

    For the first time, the laser resonance photo-ionization technique has been applied inside a FEBIAD-type ion source at an ISOL facility. This was achieved by combining the ISOLDE RILIS with the ISOLDE variant of the FEBIAD ion source (the VADIS) in a series of off-line and on-line tests at CERN. The immediate applications of these developments include the coupling of the RILIS with molten targets at ISOLDE and the introduction of two new modes of FEBIAD operation: an element selective RILIS mode and a RILIS + VADIS mode for increased efficiency compared to VADIS mode operation alone. This functionality has been demonstrated off-line for gallium and barium and on-line for mercury and cadmium. Following this work, the RILIS mode of operation was successfully applied on-line for the study of nuclear ground state and isomer properties of mercury isotopes by in-source resonance ionization laser spectroscopy. The results from the first studies of the new operational modes, of what has been termed the Versatile Arc Discharge and Laser Ion Source (VADLIS), are presented and possible directions for future developments are outlined.

  2. Improvement in brightness of multicusp-plasma ion source

    Energy Technology Data Exchange (ETDEWEB)

    Ji, Q.; Jiang, X.; King, T-J.; Leung, K-N.; Standiford, K.; Wilde, S.B.

    2002-05-24

    The beam brightness of a multicusp-plasma ion source has been substantially improved by optimizing the source configuration and extractor geometry. The current density of a 2 keV He{sup +} beam extracted from a 7.5-cm-diameter source operating at 2.5 kW RF power is {approx}100 mA/cm{sup 2}, which is {approx}10 times larger than that of a beam extracted from a 5-cm-diameter source operating at 1 kW RF power. A smaller focused beam spot size is achieved with a counter-bored extractor instead of a conventional (''through-hole'') extractor, resulting another order of magnitude improvement in beam current density. Measured brightness can be as high as 440 A/cm{sup 2}Sr, which represents a 30 times improvement over prior work.

  3. Industrial ion source technology. [for ion beam etching, surface texturing, and deposition

    Science.gov (United States)

    Kaufman, H. R.

    1977-01-01

    Plasma probe surveys were conducted in a 30-cm source to verify that the uniformity in the ion beam is the result of a corresponding uniformity in the discharge-chamber plasma. A 15 cm permanent magnet multipole ion source was designed, fabricated, and demonstrated. Procedures were investigated for texturing a variety of seed and surface materials for controlling secondary electron emission, increasing electron absorption of light, and improved attachment of biological tissue for medical implants using argon and tetrafluoromethane as the working gases. The cross section for argon-argon elastic collisions in the ion-beam energy range was calculated from interaction potentials and permits calculation of beam interaction effects that can determine system pumping requirements. The data also indicate that different optimizations of ion-beam machines will be advantageous for long and short runs, with 1 mA-hr/cm being the rough dividing line for run length. The capacity to simultaneously optimize components in an ion-beam machine for a single application, a capacity that is not evident in competitive approaches such as diode sputtering is emphasized.

  4. Improvement of the ion source power supply for JT-60 negative-ion based NBI

    Energy Technology Data Exchange (ETDEWEB)

    Omori, K.; Usui, K.; Ohshima, K.; Ohga, T.; Kawai, M.; Watanabe, K.; Itoh, T.; Kuriyama, M. [Japan Atomic Energy Research Inst., Naka, Ibaraki (Japan). Naka Fusion Research Establishment; Ono, Y. [Hitachi Ltd (Japan); Kawashima, S. [Toshiba Corp. (Japan)

    1998-07-01

    In the operation of the N-NBI since 1996, many troubles in the power supplies both the negative-ion generation/extraction and the acceleration have been experienced. Most of the problems broken out in the operation have been caused by the ion source breakdown when increasing the beam power. Those have been solved by altering the components of the power supply hardware and remodeling of the control system and an injection power of 5.2 MW at 350 keV has already been obtained. (author)

  5. Source fabrication and lifetime for Li+ ion beams extracted from alumino-silicate sources

    Energy Technology Data Exchange (ETDEWEB)

    Roy, Prabir K.; Greenway, Wayne G.; Kwan, Joe W.

    2012-04-01

    A space-charge-limited beam with current densities (J) exceeding 1 mA/cm2 have been measured from lithium alumino-silicate ion sources at a temperature of ~1275 °C. At higher extraction voltages, the source appears to become emission limited with J ≥ 1.5 mA/cm2, and J increases weakly with the applied voltage. A 6.35 mm diameter source with an alumino-silicate coating, ≤0.25 mm thick, has a measured lifetime of ~40 h at ~1275 °C, when pulsed at 0.05 Hz and with pulse length of ~6 μs each. At this rate, the source lifetime was independent of the actual beam charge extracted due to the loss of neutral atoms at high temperature. Finally, the source lifetime increases with the amount of alumino-silicate coated on the emitting surface, and may also be further extended if the temperature is reduced between pulses.

  6. Source fabrication and lifetime for Li+ ion beams extracted from alumino-silicate sources

    Energy Technology Data Exchange (ETDEWEB)

    Roy, Prabir K.; Greenway, Wayne G.; Kwan, Joe W

    2012-03-05

    A space-charge-limited beam with current densities (J) exceeding 1 mA/cm2 have been measured from lithium alumino-silicate ion sources at a temperature of ~1275 °C. At higher extraction voltages, the source appears to become emission limited with J ≥ 1.5 mA/cm2, and J increases weakly with the applied voltage. A 6.35 mm diameter source with an alumino-silicate coating, ≤0.25 mm thick, has a measured lifetime of ~40 h at ~1275 °C, when pulsed at 0.05 Hz and with pulse length of ~6 μs each. At this rate, the source lifetime was independent of the actual beam charge extracted due to the loss of neutral atoms at high temperature. Finally, the source lifetime increases with the amount of alumino-silicate coated on the emitting surface, and may also be further extended if the temperature is reduced between pulses.

  7. Ion source memory in {sup 36}Cl accelerator mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Pavetich, Stefan; Akhmadaliev, Shavkat; Merchel, Silke; Rugel, Georg [HZDR, Dresden (Germany); Arnold, Maurice; Aumaitre, Georges; Bourles, Didier; Martschini, Martin [ASTER, Aix-en-Provence (France); Buchriegler, Josef; Golser, Robin; Keddadouche, Karim; Steier, Peter [VERA, Vienna (Austria)

    2013-07-01

    Since the DREAMS (Dresden Accelerator Mass Spectrometry) facility went operational in 2011, constant effort was put into enabling routine measurements of long-lived radionuclides as {sup 10}Be, {sup 26}Al and {sup 41}Ca. For precise AMS-measurements of the volatile element Cl the key issue is the minimization of the long term memory effect. For this purpose one of the two original HVE sources was mechanically modified, allowing the usage of bigger cathodes with individual target apertures. Additionally a more open geometry was used to improve the vacuum level. To evaluate this improvement in comparison to other up-to-date ion sources, a small inter-laboratory comparison had been initiated. The long-term memory effect in the Cs sputter ion sources of the AMS facilities VERA, ASTER and DREAMS had been investigated by running samples of natural {sup 35}Cl/{sup 37}Cl-ratio and samples containing highly enriched {sup 35}Cl({sup 35}Cl/{sup 37}Cl > 500). Primary goals of the research are the time constants of the recovery from the contaminated sample ratio to the initial ratio of the sample and the level of the long-term memory effect in the sources.

  8. Review of ISOL target-ion-source systems

    Energy Technology Data Exchange (ETDEWEB)

    Kirchner, R. E-mail: r.kirchner@gsi.de

    2003-05-01

    Any review of target-ion-source systems (TISS) is necessarily a variation of the ISOL-theme 'efficient, fast, selective'. In the first part, more than 30 years of TISS development are examined in view of these key characteristics. By looking at the lines of development that were successful, at the lines that were abandoned (partly for good, partly for less good reasons), the lines with the most promising perspectives emerge. The second part deals with on-line chemistry in the TISS and its possibly double benefits: enhanced selectivity or increased separation speed, or both in favourable cases, as the relatively new sulfide chemistry. For the group-IVa-elements germanium and tin, the separation as sulfide-ions does not only suppress strongly the contamination by the neighbouring elements. It also reduces the effusion part of the release by orders of magnitude to the level of the intrinsic delay caused by molecular flow. The homologue chemistry is likely to work for silicon, but not for lead. While selectivity requires that both the formed molecules and molecular ions are thermally stable, a gain in speed requires only sufficient stability of the molecule: e.g. antimony, which hardly forms sulfide ions, also migrates orders of magnitude faster in the presence of sulphur vapour.

  9. Development of a novel radio-frequency negative hydrogen ion source in conically converging configuration.

    Science.gov (United States)

    Jung, B K; Dang, J J; An, Y H; Chung, K J; Hwang, Y S

    2014-02-01

    Volume-produced negative ion source still requires enhancement of current density with lower input RF (radio-frequency) power in lower operating pressure for various applications. To confirm recent observation of efficient negative ion production with a short cylindrical chamber with smaller effective plasma size, the RF-driven transformer-coupled plasma H(-) ion source at Seoul National University is modified by adopting a newly designed quartz RF window to reduce the chamber length. Experiments with the reduced chamber length show a few times enhancement of H(-) ion beam current compared to that extracted from the previous chamber design, which is consistent with the measured H(-) ion population. Nevertheless, decrease in H(-) ion beam current observed in low pressure regime below ∼5 mTorr owing to insufficient filtering of high energy electrons in the extraction region needs to be resolved to address the usefulness of electron temperature control by the change of geometrical configuration of the discharge chamber. A new discharge chamber with conically converging configuration has been developed, in which the chamber diameter decreases as approaching to the extraction region away from the planar RF antenna such that stronger filter magnetic field can be utilized to prohibit high energy electrons from transporting to the extraction region. First experimental results for the H(-) ion beam extraction with this configuration show that higher magnetic filter field makes peak negative beam currents happen in lower operating pressure. However, overall decrease in H(-) ion beam current due to the change of chamber geometry still requires further study of geometrical effect on particle transport and optimization of magnetic field in this novel configuration.

  10. Development of a high-current hydrogen-negative ion source for LHD-NBI system

    Energy Technology Data Exchange (ETDEWEB)

    Takeiri, Yasuhiko; Osakabe, Masaki; Tsumori, Katsuyoshi; Oka, Yoshihide; Kaneko, Osamu; Asano, Eiji; Kawamoto, Toshikazu; Akiyama, Ryuichi [National Inst. for Fusion Science, Toki, Gifu (Japan); Tanaka, Masanobu

    1998-08-01

    We have developed a high-current hydrogen-negative ion source for a negative-ion-based NBI system in Large Helical Device (LHD). The ion source is a cesium-seeded volume-production source equipped with an external magnetic filter. An arc chamber is rectangular, the dimensions of which are 35 cm x 145 cm in cross section and 21 cm in depth. A three-grid single-stage accelerator is divided into five sections longitudinally, each of which has 154(14 x 11) apertures in an area of 25 cm x 25 cm. The ion source was tested in the negative-NBI teststand, and 25 A of the negative ion beam is incident on a beamdump 13 m downstream with an energy of 104 keV for 1 sec. Multibeamlets of 770 are focused on a focal point 13 m downstream with an averaged divergence angle of 10 mrad by the geometrical arrangement of five sections of grid and the aperture displacement technique of the grounded grid. A uniform beam in the vertical direction over 125 cm is obtained with uniform plasma production in the arc chamber by balancing individual arc currents flowing through each filament. Long-pulse beam production was performed, and 1.3 MW of the negative ion beam is incident on the beamdump for 10 sec, and the temperature rise of the cooling water is almost saturated for the extraction and the grounded grids. These results satisfy the first-step specification of the LHD-NBI system. (author)

  11. Production and decay of chlorine ion excited species in an electron cyclotron resonance ion source plasma

    Energy Technology Data Exchange (ETDEWEB)

    Santos, J P; Martins, M C; Parente, F [Centro de Fisica Atomica, CFA, Departamento de Fisica, Faculdade de Ciencias e Tecnologia, FCT, Universidade Nova de Lisboa, 2829-516 Caparica (Portugal); Costa, A M; Marques, J P [Centro de Fisica Atomica, CFA, Departamento de Fisica, Faculdade de Ciencias, FCUL, Universidade de Lisboa, Campo Grande, 1749-016 Lisboa (Portugal); Indelicato, P, E-mail: jps@fct.unl.pt [Laboratoire Kastler Brossel, Ecole Normale Superieure, CNRS, Universite P et M Curie-Paris 6, Case 74, 4 place Jussieu, 75252 Paris Cedex 05 (France)

    2011-06-15

    The most important processes for the creation of chlorine ion excited states from the ground configurations of Cl{sup 10+} to Cl{sup 15+} ions in an electron cyclotron resonance ion source, leading to the emission of K x-ray lines, were studied. Theoretical values for inner-shell excitation and ionization cross-sections, including double KL and triple KLL ionization, transition probabilities and energies for the de-excitation processes, were calculated in the framework of the multi-configuration Dirac-Fock method. With reasonable assumptions about the electron energy distribution, a theoretical K{alpha} x-ray spectrum was obtained, which was then compared with recent experimental data.

  12. Time evolution of bremsstrahlung and ion production of an electron cyclotron resonance ion source

    Energy Technology Data Exchange (ETDEWEB)

    Tarvainen, Ollie [Los Alamos National Laboratory; Ropponen, Tommi [UNIV OF JYVASKYLA; Jones, Peter [UNIV OF JYVASKYLA; Peura, Pauli [UNIV OF JYVASKYLA

    2008-01-01

    Bremsstrahlung radiation measurement is one of the most commonly used plasma diagnostics methods. Most of the bremsstrahlung measurements with electron cyclotron resonance (ECR) ion sources have been performed in continuous operation mode yielding information only on the steady state bremsstrahlung emission. This article describes the results of bremsstrahlung and ion current measurement with the JYFL 14 GHz ECRIS operated in pulsed mode. The experiments reveal information about the bremsstrahlung radiation in plasma conditions before reaching the equilibrium. The time scale of bremsstrahlung production is compared to ion production time scale for different charge states. The bremsstrahlung data is presented with 2 millisecond time intervals as a function of neutral gas pressure and microwave power. Data from hundreds of microwave pulses is combined in order to have a sufficient amount of events at each time step. The relevant plasma physics phenomena during both, the leading and the trailing edge of the RF pulse, are discussed.

  13. Lithium Ion Electrolytes and Lithium Ion Cells With Good Low Temperature Performance

    Science.gov (United States)

    Smart, Marshall C. (Inventor); Bugga, Ratnakumar V. (Inventor)

    2014-01-01

    There is provided in one embodiment of the invention an electrolyte for use in a lithium ion electrochemical cell. The electrolyte comprises a mixture of an ethylene carbonate (EC), an ethyl methyl carbonate (EMC), an ester cosolvent, and a lithium salt. The ester cosolvent comprises methyl propionate (MP), ethyl propionate (EP), methyl butyrate (MB), ethyl butyrate (EB), propyl butyrate (PB), or butyl butyrate (BB). The electrochemical cell operates in a temperature range of from about -60 C to about 60 C. In another embodiment there is provided a lithium ion electrochemical cell using the electrolyte of the invention.

  14. Electromagnetic diagnostics of ECR-Ion Sources plasmas: optical/X-ray imaging and spectroscopy

    Science.gov (United States)

    Mascali, D.; Castro, G.; Altana, C.; Caliri, C.; Mazzaglia, M.; Romano, F. P.; Leone, F.; Musumarra, A.; Naselli, E.; Reitano, R.; Torrisi, G.; Celona, L.; Cosentino, L. G.; Giarrusso, M.; Gammino, S.

    2017-12-01

    Magnetoplasmas in ECR-Ion Sources are excited from gaseous elements or vapours by microwaves in the range 2.45–28 GHz via Electron Cyclotron Resonance. A B-minimum, magnetohydrodynamic stable configuration is used for trapping the plasma. The values of plasma density, temperature and confinement times are typically ne= 1011‑1013 cm‑3, 01 eVSilicon Drift detectors with high energy resolution of 125 eV at 5.9 keV have been used for the characterization of plasma emission at 02magnetic field profile (they are critical for high-power proton sources).

  15. Thermal Analysis of the Linac3 GTS-LHC ECR Ion Source

    CERN Document Server

    Fichera, Claudio; Toivanen, Ville Aleksi; Kuchler, Detlef; CERN. Geneva. ATS Department

    2017-01-01

    The Linac3 ion source produces lead beams by the vaporization of solid samples inside internal ovens. The geometry, materials and surface state of the oven elements are critical parameters influencing the temperature distribution in the environment, and thus the performance of the source. A finite element approach is proposed to evaluate the thermal response of the system at increasing heating powers. Comparisons between the simulations results and experimental measurements are given in order to validate the numerical model. Based on the obtained results, improvements to the existing setup are suggested.

  16. Extraction simulations and emittance measurements of a Holifield Radioactive Ion Beam Facility electron beam plasma source for radioactive ion beams

    Energy Technology Data Exchange (ETDEWEB)

    Mendez, A. J. II; Liu, Y. [Holifield Radioactive Ion Beam Facility, Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831 (United States)

    2010-02-15

    The Holifield Radioactive Ion Beam Facility (HRIBF) at Oak Ridge National Laboratory has a variety of ion sources used to produce radioactive ion beams (RIBs). Of these, the workhorse is an electron beam plasma (EBP) ion source. The recent addition of a second RIB injector, the Injector for Radioactive Ion Species 2 (IRIS2), for the HRIBF tandem accelerator prompted new studies of the optics of the beam extraction from the EBP source. The source was modeled using SIMION V8.0, and results will be presented, including comparison of the emittances as predicted by simulation and as measured at the HRIBF offline ion source test facilities. Also presented will be the impact on phase space shape resulting from extraction optics modifications implemented at IRIS2.

  17. CORONAL SOURCES, ELEMENTAL FRACTIONATION, AND RELEASE MECHANISMS OF HEAVY ION DROPOUTS IN THE SOLAR WIND

    Energy Technology Data Exchange (ETDEWEB)

    Weberg, Micah J. [PhD Candidate in Space Science, Department of Atmospheric, Oceanic, and Space Sciences, University of Michigan, 2134A Space Research Building, 2455 Hayward Street, Ann Arbor, MI 48109-2143, USA. (United States); Lepri, Susan T. [Associate Professor, Department of Atmospheric, Oceanic, and Space Sciences, University of Michigan, 2429 Space Research Building, 2455 Hayward Street, Ann Arbor, MI 48109-2143, USA. (United States); Zurbuchen, Thomas H., E-mail: mjweberg@umich.edu, E-mail: slepri@umich.edu, E-mail: thomasz@umich.edu [Professor, Space Science and Aerospace Engineering, Associate Dean for Entrepreneurship Senior Counselor of Entrepreneurship Education, Department of Atmospheric, Oceanic, and Space Sciences, University of Michigan, 2431 Space Research Building, 2455 Hayward Street, Ann Arbor, MI 48109-2143, USA. (United States)

    2015-03-10

    The elemental abundances of heavy ions (masses larger than He) in the solar wind provide information about physical processes occurring in the corona. Additionally, the charge state distributions of these heavy ions are sensitive to the temperature profiles of their respective source regions in the corona. Heavy ion dropouts are a relatively new class of solar wind events identified by both elemental and ionic charge state distributions. We have shown that their origins lie in large, closed coronal loops where processes such as gravitational settling dominate and can cause a mass-dependent fractionation pattern. In this study we consider and attempt to answer three fundamental questions concerning heavy ion dropouts: (1) 'where are the source loops located in the large-scale corona?'; (2) 'how does the interplay between coronal processes influence the end elemental abundances?'; and (3) 'what are the most probable release mechanisms'? We begin by analyzing the temporal and spatial variability of heavy ion dropouts and their correlation with heliospheric plasma and magnetic structures. Next we investigate the ordering of the elements inside dropouts with respect to mass, ionic charge state, and first ionization potential. Finally, we discuss these results in the context of the prevailing solar wind theories and the processes they posit that may be responsible for the release of coronal plasma into interplanetary space.

  18. Aspects of the physics, chemistry, and technology of high intensity heavy ion sources

    Energy Technology Data Exchange (ETDEWEB)

    Alton, G. D.

    1980-01-01

    Particular emphasis is placed on the technology of plasma discharge ion sources which utilize solid elemental or molecular compounds to produce vapor for the ionization process. A brief discussion is made of the elementary concepts underlying the formation and extraction of ion beams from plasma discharge sources. A limited review of low charge state positive ion sources suitable for accelerator use is also given.

  19. New progress of high current gasdynamic ion source (invited)

    Energy Technology Data Exchange (ETDEWEB)

    Skalyga, V., E-mail: skalyga@ipfran.ru; Sidorov, A.; Vodopyanov, A. [Institute of Applied Physics, Russian Academy of Sciences (IAP RAS), 46 Ul‘yanova St., 603950 Nizhny Novgorod (Russian Federation); Lobachevsky State University of Nizhny Novgorod (UNN), 23 Gagarina St., 603950 Nizhny Novgorod (Russian Federation); Izotov, I.; Golubev, S.; Razin, S. [Institute of Applied Physics, Russian Academy of Sciences (IAP RAS), 46 Ul‘yanova St., 603950 Nizhny Novgorod (Russian Federation); Tarvainen, O.; Koivisto, H.; Kalvas, T. [Department of Physics, University of Jyvaskyla, P.O. Box 35 (YFL), 40500 Jyvaskyla (Finland)

    2016-02-15

    The experimental and theoretical research carried out at the Institute of Applied Physics resulted in development of a new type of electron cyclotron resonance ion sources (ECRISs)—the gasdynamic ECRIS. The gasdynamic ECRIS features a confinement mechanism in a magnetic trap that is different from Geller’s ECRIS confinement, i.e., the quasi-gasdynamic one similar to that in fusion mirror traps. Experimental studies of gasdynamic ECRIS were performed at Simple Mirror Ion Source (SMIS) 37 facility. The plasma was created by 37.5 and 75 GHz gyrotron radiation with power up to 100 kW. High frequency microwaves allowed to create and sustain plasma with significant density (up to 8 × 10{sup 13} cm{sup −3}) and to maintain the main advantages of conventional ECRIS such as high ionization degree and low ion energy. Reaching such high plasma density relies on the fact that the critical density grows with the microwave frequency squared. High microwave power provided the average electron energy on a level of 50-300 eV enough for efficient ionization even at neutral gas pressure range of 10{sup −4}–10{sup −3} mbar. Gasdynamic ECRIS has demonstrated a good performance producing high current (100-300 mA) multi-charged ion beams with moderate average charge (Z = 4-5 for argon). Gasdynamic ECRIS has appeared to be especially effective in low emittance hydrogen and deuterium beams formation. Proton beams with current up to 500 emA and RMS emittance below 0.07 π ⋅ mm ⋅ mrad have been demonstrated in recent experiments.

  20. Glow plasma trigger for electron cyclotron resonance ion sources.

    Science.gov (United States)

    Vodopianov, A V; Golubev, S V; Izotov, I V; Nikolaev, A G; Oks, E M; Savkin, K P; Yushkov, G Yu

    2010-02-01

    Electron cyclotron resonance ion sources (ECRISs) are particularly useful for nuclear, atomic, and high energy physics, as unique high current generators of multicharged ion beams. Plasmas of gas discharges in an open magnetic trap heated by pulsed (100 micros and longer) high power (100 kW and higher) high-frequency (greater than 37.5 GHz) microwaves of gyrotrons is promising in the field of research in the development of electron cyclotron resonance sources for high charge state ion beams. Reaching high ion charge states requires a decrease in gas pressure in the magnetic trap, but this method leads to increases in time, in which the microwave discharge develops. The gas breakdown and microwave discharge duration becomes greater than or equal to the microwave pulse duration when the pressure is decreased. This makes reaching the critical plasma density initiate an electron cyclotron resonance (ECR) discharge during pulse of microwave gyrotron radiation with gas pressure lower than a certain threshold. In order to reduce losses of microwave power, it is necessary to shorten the time of development of the ECR discharge. For fast triggering of ECR discharge under low pressure in an ECRIS, we initially propose to fill the magnetic trap with the plasmas of auxiliary pulsed discharges in crossed ExB fields. The glow plasma trigger of ECR based on a Penning or magnetron discharge has made it possible not only to fill the trap with plasma with density of 10(12) cm(-3), required for a rapid increase in plasma density and finally for ECR discharge ignition, but also to initially heat the plasma electrons to T(e) approximately = 20 eV.

  1. The ISOLDE Laser Ion Source and Trap (LIST): Towards pure ion beams

    Energy Technology Data Exchange (ETDEWEB)

    Fink, Daniel [CERN, Geneva (Switzerland); University of Heidelberg (Germany); Blaum, Klaus [University of Heidelberg (Germany); Max-Planck-Institut fuer Kernphysik, Heidelberg (Germany); Catheral, Richard; Fedosseev, Valentin; Gottberg, Alexander; Marsh, Bruce; Rossel, Ralf Erik; Rothe, Sebastian; Stora, Thierry [CERN, Geneva (Switzerland); Kron, Tobias; Richter, Sven; Wendt, Klaus [University of Mainz (Germany)

    2013-07-01

    The on-line isotope mass separator ISOLDE at CERN is a facility dedicated to the production of a large variety of radioactive ion beams. A high ionization efficiency combined with ultimate isotope selectivity is of utmost importance for all on-line experiments on exotic, short-lived radionuclides with the lowest production rates. The ionization technique that most closely meets this requirement is the element selective Resonance Ionization Laser Ion Source (RILIS). Unfortunately, even when the RILIS is used, many rare isotope beams produced at ISOLDE remain contaminated with surface ionized isobars. In order to suppress the surface ions, a radio-frequency quadrupole device known as the Laser Ion Source and Trap (LIST) has been developed at the University of Mainz and at CERN. After the first successful on-line test in 2011, the LIST was further improved in terms of efficiency, selectivity, and reliability through several off-line tests at Mainz University and at ISOLDE/CERN. In September 2012, the first on-line physics experiments to use the LIST took place at ISOLDE. A summary of the LIST technology and the results of the on-line characterization and experiments are given.

  2. Ionization efficiency studies for xenon ions with thesuperconducting ECR ion source VENUS

    Energy Technology Data Exchange (ETDEWEB)

    Leitner, Daniela; Lyneis, Claude M.; Todd, DamonS.; Tarvainen,Olli

    2007-06-05

    Ionization efficiency studies for high charge state xenon ions using a calibrated gas leak are presented. A 75% enriched {sup 129}Xe gas leak with a gas flow equivalent to 5.11p{mu}A was used in all the measurements. The experiments were performed at the VENUS (Versatile ECR ion source for Nuclear Science) ion source for 18 GHz, 28 GHz and double frequency operation. Overall, total ionization efficiencies close to 100% and ionization efficiencies into a single charge state up to 22% were measured. The influence of the biased disk on the ionization efficiency was studied and the results were somewhat surprising. When the biased disk was removed from the plasma chamber, the ionization efficiency was dramatically reduced for single frequency operation. However, using double frequency heating the ionization efficiencies achieved without the biased disk almost matched the ionization efficiencies achieved with the biased probe. In addition, we have studied the influence of the support gas on the charge state distribution of the xenon ions. Either pure oxygen or a mixture of oxygen and helium were used as support gases. The addition of a small amount of helium can increase the ionization efficiency into a single charge state by narrowing the charge state distribution. Furthermore by varying the helium flow the most efficient charge state can be shifted over a wide range without compromising the ionization efficiency. This is not possible using only oxygen as support gas. Results from these studies are presented and discussed.

  3. High intensity metallic ion beam from an ecr ion source using the Mivoc method

    Energy Technology Data Exchange (ETDEWEB)

    Barue, C.; Canet, C.; Dupuis, M.; Flambard, J.L.; Leherissier, P.; Lemagnen, F. [Grand Accelerateur National d' Ions Lourds (GANIL), 14 - Caen (France); Jaffres, P.A. [Institut des Sciences de la Matiere et du Rayonnement, SIMRa, 14 - Cean (France)

    2000-07-01

    The MIVOC method has been successfully used at GANIL to produce a high intensity nickel beam with the ECR4 ion source: 20 {mu}A {sup 58}Ni{sup 11+} at 24 kV extraction voltage. This beam has been maintained for 8 days and accelerated up to 74.5 MeV/u by our cyclotrons with a mean intensity of 0.13 p{mu}A on target. This high intensity, required for experiment, led to the discovery of the doubly magic {sup 48}Ni isotope. Experimental setup, handling and off-line preparation using a residual gas analyzer are described in this report. The ion source behavior, performances and limitations are presented in the case of nickel and iron. The ionization efficiencies have been measured and compared to the oven method usually used at GANIL. (author)

  4. Optimization and Domestic Sourcing of Lithium Ion Battery Anode Materials

    Energy Technology Data Exchange (ETDEWEB)

    Wood, III, D. L.; Yoon, S. [A123 Systems, Inc.

    2012-10-25

    The purpose of this Cooperative Research and Development Agreement (CRADA) between ORNL and A123Systems, Inc. was to develop a low-temperature heat treatment process for natural graphite based anode materials for high-capacity and long-cycle-life lithium ion batteries. Three major problems currently plague state-of-the-art lithium ion battery anode materials. The first is the cost of the artificial graphite, which is heat-treated well in excess of 2000°C. Because of this high-temperature heat treatment, the anode active material significantly contributes to the cost of a lithium ion battery. The second problem is the limited specific capacity of state-of-the-art anodes based on artificial graphites, which is only about 200-350 mAh/g. This value needs to be increased to achieve high energy density when used with the low cell-voltage nanoparticle LiFePO4 cathode. Thirdly, the rate capability under cycling conditions of natural graphite based materials must be improved to match that of the nanoparticle LiFePO4. Natural graphite materials contain inherent crystallinity and lithium intercalation activity. They hold particular appeal, as they offer huge potential for industrial energy savings with the energy costs essentially subsidized by geological processes. Natural graphites have been heat-treated to a substantially lower temperature (as low as 1000-1500°C) and used as anode active materials to address the problems described above. Finally, corresponding graphitization and post-treatment processes were developed that are amenable to scaling to automotive quantities.

  5. H- Ion Sources for High Intensity Proton Drivers

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Rolland Paul [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Dudnikov, Vadim [Muons, Inc., Batavia, IL (United States)

    2015-02-20

    Existing RF Surface Plasma Sources (SPS) for accelerators have specific efficiencies for H+ and H- ion generation around 3 to 5 mA/cm2 per kW, where about 50 kW of RF power is typically needed for 50 mA beam current production. The Saddle Antenna (SA) SPS described here was developed to improve H- ion production efficiency, reliability and availability for pulsed operation as used in the ORNL Spallation Neutron Source . At low RF power, the efficiency of positive ion generation in the plasma has been improved to 200 mA/cm2 per kW of RF power at 13.56 MHz. Initial cesiation of the SPS was performed by heating cesium chromate cartridges by discharge as was done in the very first versions of the SPS. A small oven to decompose cesium compounds and alloys was developed and tested. After cesiation, the current of negative ions to the collector was increased from 1 mA to 10 mA with RF power 1.5 kW in the plasma (6 mm diameter emission aperture) and up to 30 mA with 4 kW RF power in the plasma and 250 Gauss longitudinal magnetic field. The ratio of electron current to negative ion current was improved from 30 to 2. Stable generation of H- beam without intensity degradation was demonstrated in the aluminum nitride (AlN) discharge chamber for 32 days at high discharge power in an RF SPS with an external antenna. Some modifications were made to improve the cooling and cesiation stability. The extracted collector current can be increased significantly by optimizing the longitudinal magnetic field in the discharge chamber. While this project demonstrated the advantages of the pulsed version of the SA RF SPS as an upgrade to the ORNL Spallation Neutron Source, it led to a possibility for upgrades to CW machines like the many cyclotrons used for commercial applications. Four appendices contain important details of the work carried out under this grant.

  6. Three-dimensional simulations of ion dynamics in the plasma of an electron cyclotron resonance ion source

    NARCIS (Netherlands)

    Mironov, V.; Beijers, J.P.M.

    The ion production in an electron cyclotron resonance ion source (ECRIS) is modeled using a particle-in-cell Monte-Carlo-collision code in a three-dimensional geometry. Only the heavy particles (ions and atoms) are tracked, while the electrons are represented using a Maxwell-Boltzmann energy

  7. Heavy-ion sources: The Star, or the Cinderella, of the ion-implantation firmament? (invited)

    Science.gov (United States)

    Freeman, Harry

    2000-02-01

    The Star, because of the invaluable contribution which the heavy-ion source has already made to the successful development of semiconductor implantation. And the Star, too, because it is evident that the key characteristics of such sources, which are now used on a quite routine industrial basis—their reliability, their ease of operation and, above all, their extraordinary versatility—have still not been fully exploited. This ensures that there is still scope, at least in the short term, for further optimization, which will go some way to meet the increasingly stringent industrial doping requirements. The Cinderella, because of my belief that these heavy-ion sources have now contributed to the successful operation of ion implanters so well, and for so long, that their present level of performance is mistakenly taken for granted. The result has been a paucity of meaningful research and development. Despite this, in this article I aim to show that, like Cinderella, who was so neglected that her true merit was long overlooked, there is the prospect too of achieving the significantly larger improvements in beam quality which the semiconductor industry will eventually be seeking.

  8. A HIGH CURRENT DENSITY LI+ ALUMINO-SILICATE ION SOURCE FOR TARGET HEATING EXPERIMENTS

    Energy Technology Data Exchange (ETDEWEB)

    Roy, Prabir K.; Greenway, Wayne G.; Kwan, Joe W.; Seidl, Peter A.; Waldron, William L.

    2011-03-23

    The NDCX-II accelerator for target heating experiments has been designed to use a large diameter ({approx_equal} 10.9 cm) Li{sup +} doped alumino-silicate source with a pulse duration of 0.5 {micro}s, and beam current of {approx_equal} 93 mA. Characterization of a prototype lithium alumino-silicate sources is presented. Using 6.35mm diameter prototype emitters (coated on a {approx_equal} 75% porous tungsten substrate), at a temperature of {approx_equal} 1275 C, a space-charge limited Li{sup +} beam current density of {approx_equal} 1 mA/cm{sup 2} was measured. At higher extraction voltage, the source is emission limited at around {approx_equal} 1.5 mA/cm{sup 2}, weakly dependent on the applied voltage. The lifetime of the ion source is {approx_equal} 50 hours while pulsing the extraction voltage at 2 to 3 times per minute. Measurements show that the life time of the ion source does not depend only on beam current extraction, and lithium loss may be dominated by neutral loss or by evaporation. The life time of a source is around {ge} 10 hours in a DC mode extraction, and the extracted charge is {approx_equal} 75% of the available Li in the sample. It is inferred that pulsed heating may increase the life time of a source.

  9. Pulsed ion sheath dynamics in a cylindrical bore for inner surface grid-enhanced plasma source ion implantation

    CERN Document Server

    Wang Jiu Li; Fan Song Hua; Yang Wu Bao; Yang Size

    2002-01-01

    Based on authors' recently proposed grid-enhanced plasma source ion implantation (GEPSII) technique for inner surface modification of materials with cylindrical geometry, the authors present the corresponding theoretical studies of the temporal evolution of the plasma ion sheath between the grid electrode and the target in a cylindrical bore. Typical results such as the ion sheath evolution, time-dependent ion density and time-integrated ion energy distribution at the target are calculated by solving Poisson's equation coupled with fluid equations for collisionless ions and Boltzmann assumption for electrons using finite difference methods. The calculated results can further verify the feasibility and superiority of this new technique

  10. Initial value problem of the toroidal ion temperature gradient mode

    Energy Technology Data Exchange (ETDEWEB)

    Kuroda, T.; Sugama, H.; Kanno, R.; Okamoto, M. [National Inst. for Fusion Science, Toki, Gifu (Japan); Horton, W.

    1998-06-01

    The initial value problem of the toroidal ion temperature gradient mode is studied based on the Laplace transform of the ion gyrokinetic equation and the electron Boltzmann relation with the charge neutrality condition. Due to the toroidal magnetic drift, the Laplace-transformed density and potential perturbations have a branch cut as well as poles on the complex-frequency plane. The inverse Laplace transform shows that the temporal evolution of the density and potential perturbations consists of the normal modes and the continuum mode, which correspond to contributions from the poles and the branch cut, respectively. The normal modes have exponential time dependence with the eigenfrequencies determined by the dispersion relation while the continuum mode shows power-law decay oscillation. For the stable case, the long-time asymptotic behavior of the potential and density perturbations is dominated by the continuum mode which decays slower than the normal modes. (author)

  11. New development of laser ion source for highly charged ion beam production at Institute of Modern Physics (invited)

    Science.gov (United States)

    Zhao, H. Y.; Zhang, J. J.; Jin, Q. Y.; Liu, W.; Wang, G. C.; Sun, L. T.; Zhang, X. Z.; Zhao, H. W.

    2016-02-01

    A laser ion source based on Nd:YAG laser has been being studied at the Institute of Modern Physics for the production of high intensity high charge state heavy ion beams in the past ten years, for possible applications both in a future accelerator complex and in heavy ion cancer therapy facilities. Based on the previous results for the production of multiple-charged ions from a wide range of heavy elements with a 3 J/8 ns Nd:YAG laser [Zhao et al., Rev. Sci. Instrum. 85, 02B910 (2014)], higher laser energy and intensity in the focal spot are necessary for the production of highly charged ions from the elements heavier than aluminum. Therefore, the laser ion source was upgraded with a new Nd:YAG laser, the maximum energy of which is 8 J and the pulse duration can be adjusted from 8 to 18 ns. Since then, the charge state distributions of ions from various elements generated by the 8 J Nd:YAG laser were investigated for different experimental conditions, such as laser energy, pulse duration, power density in the focal spot, and incidence angle. It was shown that the incidence angle is one of the most important parameters for the production of highly charged ions. The capability of producing highly charged ions from the elements lighter than silver was demonstrated with the incidence angle of 10° and laser power density of 8 × 1013 W cm-2 in the focal spot, which makes a laser ion source complementary to the superconducting electron cyclotron resonance ion source for the future accelerator complex especially in terms of the ion beam production from some refractory elements. Nevertheless, great efforts with regard to the extraction of intense ion beams, modification of the ion beam pulse duration, and reliability of the ion source still need to be made for practical applications.

  12. New development of laser ion source for highly charged ion beam production at Institute of Modern Physics (invited).

    Science.gov (United States)

    Zhao, H Y; Zhang, J J; Jin, Q Y; Liu, W; Wang, G C; Sun, L T; Zhang, X Z; Zhao, H W

    2016-02-01

    A laser ion source based on Nd:YAG laser has been being studied at the Institute of Modern Physics for the production of high intensity high charge state heavy ion beams in the past ten years, for possible applications both in a future accelerator complex and in heavy ion cancer therapy facilities. Based on the previous results for the production of multiple-charged ions from a wide range of heavy elements with a 3 J/8 ns Nd:YAG laser [Zhao et al., Rev. Sci. Instrum. 85, 02B910 (2014)], higher laser energy and intensity in the focal spot are necessary for the production of highly charged ions from the elements heavier than aluminum. Therefore, the laser ion source was upgraded with a new Nd:YAG laser, the maximum energy of which is 8 J and the pulse duration can be adjusted from 8 to 18 ns. Since then, the charge state distributions of ions from various elements generated by the 8 J Nd:YAG laser were investigated for different experimental conditions, such as laser energy, pulse duration, power density in the focal spot, and incidence angle. It was shown that the incidence angle is one of the most important parameters for the production of highly charged ions. The capability of producing highly charged ions from the elements lighter than silver was demonstrated with the incidence angle of 10° and laser power density of 8 × 10(13) W cm(-2) in the focal spot, which makes a laser ion source complementary to the superconducting electron cyclotron resonance ion source for the future accelerator complex especially in terms of the ion beam production from some refractory elements. Nevertheless, great efforts with regard to the extraction of intense ion beams, modification of the ion beam pulse duration, and reliability of the ion source still need to be made for practical applications.

  13. Experimental benchmark of the NINJA code for application to the Linac4 H‑ ion source plasma

    Science.gov (United States)

    Briefi, S.; Mattei, S.; Rauner, D.; Lettry, J.; Tran, M. Q.; Fantz, U.

    2017-10-01

    For a dedicated performance optimization of negative hydrogen ion sources applied at particle accelerators, a detailed assessment of the plasma processes is required. Due to the compact design of these sources, diagnostic access is typically limited to optical emission spectroscopy yielding only line-of-sight integrated results. In order to allow for a spatially resolved investigation, the electromagnetic particle-in-cell Monte Carlo collision code NINJA has been developed for the Linac4 ion source at CERN. This code considers the RF field generated by the ICP coil as well as the external static magnetic fields and calculates self-consistently the resulting discharge properties. NINJA is benchmarked at the diagnostically well accessible lab experiment CHARLIE (Concept studies for Helicon Assisted RF Low pressure Ion sourcEs) at varying RF power and gas pressure. A good general agreement is observed between experiment and simulation although the simulated electron density trends for varying pressure and power as well as the absolute electron temperature values deviate slightly from the measured ones. This can be explained by the assumption of strong inductive coupling in NINJA, whereas the CHARLIE discharges show the characteristics of loosely coupled plasmas. For the Linac4 plasma, this assumption is valid. Accordingly, both the absolute values of the accessible plasma parameters and their trends for varying RF power agree well in measurement and simulation. At varying RF power, the H‑ current extracted from the Linac4 source peaks at 40 kW. For volume operation, this is perfectly reflected by assessing the processes in front of the extraction aperture based on the simulation results where the highest H‑ density is obtained for the same power level. In surface operation, the production of negative hydrogen ions at the converter surface can only be considered by specialized beam formation codes, which require plasma parameters as input. It has been demonstrated

  14. Ion source development and radiobiology applications within the LIBRA project

    Science.gov (United States)

    Borghesi, M.; Kar, S.; Prasad, R.; Kakolee, F. K.; Quinn, K.; Ahmed, H.; Sarri, G.; Ramakrishna, B.; Qiao, B.; Geissler, M.; Ter-Avetisyan, S.; Zepf, M.; Schettino, G.; Stevens, B.; Tolley, M.; Ward, A.; Green, J.; Foster, P. S.; Spindloe, C.; Gallegos, P.; Robinson, A.. L.; Neely, D.; Carroll, D. C.; Tresca, O.; Yuan, X.; Quinn, M.; McKenna, P.; Dover, N.; Palmer, C.; Schreiber, J.; Najmudin, Z.; Sari, I.; Kraft, M.; Merchant, M.; Jeynes, J. C.; Kirkby, K.; Fiorini, F.; Kirby, D.; Green, S.

    2011-05-01

    In view of their properties, laser-driven ion beams have the potential to be employed in innovative applications in the scientific, technological and medical areas. Among these, a particularly high-profile application is particle therapy for cancer treatment, which however requires significant improvements from current performances of laser-driven accelerators. The focus of current research in this field is on developing suitable strategies enabling laser-accelerated ions to match these requirements, while exploiting some of the unique features of a laser-driven process. LIBRA is a UK-wide consortium, aiming to address these issues, and develop laser-driven ion sources suitable for applicative purposes, with a particular focus on biomedical applications. We will report on the activities of the consortium aimed to optimizing the properties of the beams, by developing and employing advanced targetry and by exploring novel acceleration regimes enabling production of beams with reduced energy spread. Employing the TARANIS Terawatt laser at Queen's University, we have initiated a campaign investigating the effects of proton irradiation of biological samples at extreme dose rates (> 109 Gy/s).

  15. Superconducting magnets for the RAON electron cyclotron resonance ion source.

    Science.gov (United States)

    Choi, S; Kim, Y; Hong, I S; Jeon, D

    2014-02-01

    The RAON linear accelerator of Rare Isotope Science Project has been developed since 2011, and the superconducting magnet for ECRIS was designed. The RAON ECR ion source was considered as a 3rd generation source. The fully superconducting magnet has been designed for operating using 28 GHz radio frequency. The RAON ECRIS operates in a minimum B field configuration which means that a magnetic sextupole field for radial confinement is superimposed with a magnetic mirror field for axial confinement. The highest field strength reaches 3.5 T on axis and 2 T at the plasma chamber wall for operating frequency up to 28 GHz. In this paper, the design results are presented of optimized superconducting magnet consisting of four solenoids and sextupole. The prototype magnet for ECRIS was fabricated and tested to verify the feasibility of the design. On the basis of test results, a fully superconducting magnet will be fabricated and tested.

  16. Ion Bernstein instability as a possible source for oxygen ion cyclotron harmonic waves

    Science.gov (United States)

    Min, Kyungguk; Denton, Richard E.; Liu, Kaijun; Gary, S. Peter; Spence, Harlan E.

    2017-05-01

    This paper demonstrates that an ion Bernstein instability can be a possible source for recently reported electromagnetic waves with frequencies at or near the singly ionized oxygen ion cyclotron frequency, ΩO+, and its harmonics. The particle measurements during strong wave activity revealed a relatively high concentration of oxygen ions (˜15%) whose phase space density exhibits a local peak at energy ˜20 keV. Given that the electron plasma-to-cyclotron frequency ratio is ωpe/Ωe≳1, this energy corresponds to the particle speed v/vA≳0.3, where vA is the oxygen Alfvén speed. Using the observational key plasma parameters, a simplified ion velocity distribution is constructed, where the local peak in the oxygen ion velocity distribution is represented by an isotropic shell distribution. Kinetic linear dispersion theory then predicts unstable Bernstein modes at or near the harmonics of ΩO+ and at propagation quasi-perpendicular to the background magnetic field, B0. If the cold ions are mostly protons, these unstable modes are characterized by a low compressibility (|δB∥|2/|δB|2≲0.01), a small phase speed (vph˜0.2vA), a relatively small ratio of the electric field energy to the magnetic field energy (between 10-4 and 10-3), and the Poynting vector directed almost parallel to B0. These linear properties are overall in good agreement with the properties of the observed waves. We demonstrate that superposition of the predicted unstable Bernstein modes at quasi-perpendicular propagation can produce the observed polarization properties, including the minimum variance direction on average almost parallel to B0.

  17. Characteristics of the positive ion source at reduced gas feed

    Energy Technology Data Exchange (ETDEWEB)

    Sharma, S. K., E-mail: sksharma@ipr.res.in; Bharathi, P.; Prahlad, V.; Patel, P. J.; Choksi, B.; Jana, M. R.; Bansal, L. K.; Qureshi, K.; Sumod, C. B.; Vadher, V.; Thakkar, D.; Gupta, L. N.; Rambabu, S.; Parmar, S.; Contractor, N.; Sahu, A. K.; Pandya, B.; Sridhar, B.; Pandya, S.; Baruah, U. K. [Institute for Plasma Research, Bhat, Gandhinagar (India)

    2014-11-15

    The neutral beam injector of steady state superconducting tokamak (SST1-NBI) at IPR is designed for injecting upto 1.7 MW of neutral beam (Hº, 30–55 keV) power to the tokamak plasma for heating and current drive. Operations of the positive ion source (PINI or Plug-In-Neutral-Injector) of SST1-NBI were carried out on the NBI test stand. The PINI was operated at reduced gas feed rate of 2–3 Torr l/s, without using the high speed cryo pumps. Experiments were conducted to achieve a stable beam extraction by optimizing operational parameters namely, the arc current (120–300 A), acceleration voltage (16–40 kV), and a suitable control sequence. The beam divergence, power density profiles, and species fractions (H{sup +}:H{sub 2}{sup +}:H{sub 3}{sup +}) were measured by using the diagnostics such as thermal calorimetry, infrared thermography, and Doppler shift spectroscopy. The maximum extracted beam current was about 18 A. A further increase of beam current was found to be limited by the amount of gas feed rate to the ion source.

  18. Overdense plasma generation in a compact ion source

    Science.gov (United States)

    Castro, G.; Mascali, D.; Gammino, S.; Torrisi, G.; Romano, F. P.; Celona, L.; Altana, C.; Caliri, C.; Gambino, N.; Lanaia, D.; Miracoli, R.; Neri, L.; Sorbello, G.

    2017-05-01

    Electron cyclotron resonance ion sources (ECRIS) are widely used plasma based machines for the production of intense ion beams in science and industry. The performance of modern devices is limited by the presence of the density cut-off, above which electromagnetic (EM) waves sustaining the plasma are reflected. We hereby discuss the systematic data analysis of electrostatic wave generation in an ECR prototype operating at 3.75 GHz-0.1 THz. In particular, electron Bernstein waves (EBW) have been excited. EBW have already been generated in large-scale plasma devices for thermonuclear fusion purposes. In ion sources where L c ˜ λ RF (L c being the plasma chamber size and λ RF the pumping wave wavelength) the EM field assumes a modal behaviour; thus both plasma and EM field self-organize so that no optical-like wave launching is possible (i.e. the cavity effect dominates on the optical path). The collected data, however, supported by 3D full-wave simulations, actually demonstrate that a Budden-type X-B conversion scenario can be established above some critical RF power thresholds, operating in an off-ECR regime. The generation and absorption of the EBW has been demonstrated by the presence of three peculiar signatures: along with the establishment of an overdense plasma, generation of supra-thermal electrons and modification (non-linear broadening) of the EM spectrum measured within the plasma have been observed. At the threshold establishing such a heating regime, the collected data provide evidence for a fast rotation of the electron fluid.

  19. Magnetic field design for a Penning ion source for a 200 keV electrostatic accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Fathi, A., E-mail: Atefeh.Fathi115@gmail.com [Radiation Applications Department, Shahid Beheshti University, G. C., Tehran (Iran, Islamic Republic of); Feghhi, S.A.H.; Sadati, S.M. [Radiation Applications Department, Shahid Beheshti University, G. C., Tehran (Iran, Islamic Republic of); Ebrahimibasabi, E. [Department of Physics, Shahrood University of Technology, 3619995161, Shahrood (Iran, Islamic Republic of)

    2017-04-01

    In this study, the structure of magnetic field for a Penning ion source has been designed and constructed with the use of permanent magnets. The ion source has been designed and constructed for a 200 keV electrostatic accelerator. With using CST Studio Suite, the magnetic field profile inside the ion source was simulated and an appropriate magnetic system was designed to improve particle confinement. Designed system consists of two ring magnets with 9 mm distance from each other around the anode. The ion source was constructed and the cylindrical magnet and designed magnetic system were tested on the ion source. The results showed that the ignition voltage for ion source with the designed magnetic system is almost 300 V lower than the ion source with the cylindrical magnet. Better particle confinement causes lower voltage discharge to occur.

  20. An ion species model for positive ion sources - part II analysis of hydrogen isotope effects

    CERN Document Server

    Surrey, E

    2014-01-01

    A one dimensional model of the magnetic multipole volume plasma source has been developed for application to intense ion/neutral atom beam injectors. The model uses plasma transport coefficients for particle and energy flow to create a detailed description of the plasma parameters along an axis parallel to that of the extracted beam. In this paper the isotopic modelling of positive hydrogenic ions is considered and compared with experimental data from the neutral beam injectors of the Joint European Torus. The use of the code to gain insights into the processes contributing to the ratios of the ionic species is demonstrated and the conclusion is drawn that 75% of the atomic ion species arises from ionization of dissociated molecules and 25% from dissociation of the molecular ions. However whilst the former process is independent of the filter field, the latter is sensitive to the change in distribution of fast and thermal electrons produced by the magnetic filter field and an optimum combination of field stre...

  1. Ion temperature gradient modes in toroidal helical systems

    Energy Technology Data Exchange (ETDEWEB)

    Kuroda, T. [Graduate University for Advanced Studies, Toki, Gifu (Japan); Sugama, H.; Kanno, R.; Okamoto, M.

    2000-04-01

    Linear properties of ion temperature gradient (ITG) modes in helical systems are studied. The real frequency, growth rate, and eigenfunction are obtained for both stable and unstable cases by solving a kinetic integral equation with proper analytic continuation performed in the complex frequency plane. Based on the model magnetic configuration for toroidal helical systems like the Large Helical Device (LHD), dependences of the ITG mode properties on various plasma equilibrium parameters are investigated. Particularly, relative effects of {nabla}B-curvature drifts driven by the toroidicity and by the helical ripples are examined in order to compare the ITG modes in helical systems with those in tokamaks. (author)

  2. Kinetics of electrons and neutral particles in radio-frequency transformer coupled plasma H- ion source at Seoul National University

    Science.gov (United States)

    Chung, K. J.; Dang, J. J.; Kim, J. Y.; Cho, W. H.; Hwang, Y. S.

    2016-10-01

    In volume production H- ion sources, control of electron temperature is essential due to its close correlation with the generation of vibrationally-excited hydrogen molecules in the driver region as well as the generation of H- ions by dissociative attachment in the extraction region. In the ion source group at Seoul National University (SNU) in Korea, a lot of research effort has been made to the development of a volume production H- ion source based on radio-frequency (RF) transformer-coupled plasma (TCP) for long lifetime continuous wave (CW) operation. It has a spiral RF antenna located outside the discharge chamber to generate a plasma with high electron temperature in the driver region and employs a magnetic filter field to prevent high energy electrons from being transported to the extraction region. In this paper, we present the recent progress on understanding of the underlying physics of the RF TCP H- ion source at SNU. Special attention is paid to the characterization of electron kinetics regime for controlling electron energy distribution and the influence of relaxation of neutral particles during the transport across the magnetic filter region. Effect of the degree of dissociation on the production of H- ions is also discussed.

  3. A Survey of Low-Temperature Operational Boundaries of Navy and Marine Corps Lithium and Lithium-Ion Batteries

    Science.gov (United States)

    2016-09-29

    Love 1 INTRODUCTION The U.S. Navy and Marine Corps depend on lithium (Li) and lithium-ion (Li-ion) batteries as mission- enabling power sources...Naval Research Laboratory Washington, DC 20375-5320 NRL/MR/6110--16-9695 A Survey of Low-Temperature Operational Boundaries of Navy and Marine Corps... Chemistry Branch Chemistry Division oLga a. Baturina Corey t. Love Chemical Dynamics and Diagnostics Branch Chemistry Division i REPORT

  4. Ion and electron sheath characteristics in a low density and low temperature plasma

    Science.gov (United States)

    Borgohain, Binita; Bailung, H.

    2017-11-01

    Ion and electron sheath characteristics in a low electron temperature (Te ˜ 0.25-0.40 eV) and density (ne ˜ 106-107 cm-3) plasma are described. The plasma is produced in the experimental volume through diffusion from a hot cathode discharge plasma source by using a magnetic filter. The electron energy distribution function in the experimental plasma volume is measured to be a narrow Maxwellian distribution indicating the absence of primary and energetic electrons which are decoupled in the source side by the cusp magnetic field near the filter. An emissive probe is used to measure the sheath potential profiles in front of a metal plate biased negative and positive with respect to the plasma potential. For a positive plate bias, the electron density decreases considerably and the electron sheath expands with a longer presheath region compared to the ion sheath. The sheath potential structures are found to follow the Debye sheath model.

  5. Improvements on the stability and operation of a magnetron H- ion source

    Science.gov (United States)

    Sosa, A.; Bollinger, D. S.; Karns, P. R.; Tan, C. Y.

    2017-05-01

    The magnetron H- ion sources developed in the 1970s currently in operation at Fermilab provide beam to the rest of the accelerator complex. A series of modifications to these sources have been tested in a dedicated off-line test stand with the aim of improving different operational issues. The solenoid type gas valve was tested as an alternative to the piezoelectric gas valve in order to avoid its temperature dependence. A new cesium oven was designed and tested in order to avoid glass pieces that were present with the previous oven, improve thermal insulation and fine-tune its temperature. A current-regulated arc modulator was developed to run the ion source at a constant arc current, providing very stable beam outputs during operations. In order to reduce beam noise, the addition of small amounts of N2 gas was explored, as well as testing different cathode shapes with increasing plasma volume. This paper summarizes the studies and modifications done in the source over the past three years with the aim of improving its stability, reliability and overall performance.

  6. Improvements on the stability and operation of a magnetron H^{-} ion source

    Directory of Open Access Journals (Sweden)

    A. Sosa

    2017-05-01

    Full Text Available The magnetron H^{−} ion sources developed in the 1970s currently in operation at Fermilab provide beam to the rest of the accelerator complex. A series of modifications to these sources have been tested in a dedicated off-line test stand with the aim of improving different operational issues. The solenoid type gas valve was tested as an alternative to the piezoelectric gas valve in order to avoid its temperature dependence. A new cesium oven was designed and tested in order to avoid glass pieces that were present with the previous oven, improve thermal insulation and fine-tune its temperature. A current-regulated arc modulator was developed to run the ion source at a constant arc current, providing very stable beam outputs during operations. In order to reduce beam noise, the addition of small amounts of N_{2} gas was explored, as well as testing different cathode shapes with increasing plasma volume. This paper summarizes the studies and modifications done in the source over the past three years with the aim of improving its stability, reliability and overall performance.

  7. Intense beam production of highly charged heavy ions by the superconducting electron cyclotron resonance ion source SECRAL.

    Science.gov (United States)

    Zhao, H W; Sun, L T; Zhang, X Z; Guo, X H; Cao, Y; Lu, W; Zhang, Z M; Yuan, P; Song, M T; Zhao, H Y; Jin, T; Shang, Y; Zhan, W L; Wei, B W; Xie, D Z

    2008-02-01

    There has been increasing demand to provide higher beam intensity and high enough beam energy for heavy ion accelerator and some other applications, which has driven electron cyclotron resonance (ECR) ion source to produce higher charge state ions with higher beam intensity. One of development trends for highly charged ECR ion source is to build new generation ECR sources by utilization of superconducting magnet technology. SECRAL (superconducting ECR ion source with advanced design in Lanzhou) was successfully built to produce intense beams of highly charged ion for Heavy Ion Research Facility in Lanzhou (HIRFL). The ion source has been optimized to be operated at 28 GHz for its maximum performance. The superconducting magnet confinement configuration of the ion source consists of three axial solenoid coils and six sextupole coils with a cold iron structure as field booster and clamping. An innovative design of SECRAL is that the three axial solenoid coils are located inside of the sextupole bore in order to reduce the interaction forces between the sextupole coils and the solenoid coils. For 28 GHz operation, the magnet assembly can produce peak mirror fields on axis of 3.6 T at injection, 2.2 T at extraction, and a radial sextupole field of 2.0 T at plasma chamber wall. During the commissioning phase at 18 GHz with a stainless steel chamber, tests with various gases and some metals have been conducted with microwave power less than 3.5 kW by two 18 GHz rf generators. It demonstrates the performance is very promising. Some record ion beam intensities have been produced, for instance, 810 e microA of O(7+), 505 e microA of Xe(20+), 306 e microA of Xe(27+), and so on. The effect of the magnetic field configuration on the ion source performance has been studied experimentally. SECRAL has been put into operation to provide highly charged ion beams for HIRFL facility since May 2007.

  8. Performance evaluation of a permanent ring magnet based helicon plasma source for negative ion source research

    Science.gov (United States)

    Pandey, Arun; Bandyopadhyay, M.; Sudhir, Dass; Chakraborty, A.

    2017-10-01

    Helicon wave heated plasmas are much more efficient in terms of ionization per unit power consumed. A permanent magnet based compact helicon wave heated plasma source is developed in the Institute for Plasma Research, after carefully optimizing the geometry, the frequency of the RF power, and the magnetic field conditions. The HELicon Experiment for Negative ion-I source is the single driver helicon plasma source that is being studied for the development of a large sized, multi-driver negative hydrogen ion source. In this paper, the details about the single driver machine and the results from the characterization of the device are presented. A parametric study at different pressures and magnetic field values using a 13.56 MHz RF source has been carried out in argon plasma, as an initial step towards source characterization. A theoretical model is also presented for the particle and power balance in the plasma. The ambipolar diffusion process taking place in a magnetized helicon plasma is also discussed.

  9. Study of the negative ion extraction mechanism from a double-ion plasma in negative ion sources

    Energy Technology Data Exchange (ETDEWEB)

    Goto, I.; Nishioka, S.; Hatayama, A. [Graduate school of Science and Technology, Keio University, 3-14-1 Hiyoshi, Kohoku-ku, Yokohama 223-8522 (Japan); Miyamoto, K. [Naruto University of Education, 748 Nakashima, Takashima, Naruto-cho, Naruto-shi, Tokushima 772-8502 (Japan)

    2015-04-08

    We have developed a 2D3V-PIC model of the extraction region, aiming to clarify the basic extraction mechanism of H{sup −} ions from the double-ion plasma in H{sup −} negative ion sources. The result shows the same tendency of the H{sup −} ion density n{sub H{sup −}} as that observed in the experiments, i.e.,n{sub H{sup −}} in the upstream region away from the plasma meniscus (H{sup −} emitting surface) has been reduced by applying the extraction voltage. At the same time, relatively slow temporal oscillation of the electric potential compared with the electron plasma frequency has been observed in the extraction region. Results of the systematic study using a 1D3V-PIC model with the uniform magnetic field confirm the result that the electrostatic oscillation is identified to be lower hybrid wave. The effect of this oscillation on the H{sup −} transport will be studied in the future.

  10. Multi-ion sensing of dipolar noise sources in ion traps

    Science.gov (United States)

    Galve, F.; Alonso, J.; Zambrini, R.

    2017-09-01

    Trapped-ion quantum platforms are subject to "anomalous" heating due to interactions with electric-field noise sources of nature not yet completely known. There is ample experimental evidence that this noise originates at the surfaces of the trap electrodes, and models assuming fluctuating pointlike dipoles are consistent with observations, but the exact microscopic mechanisms behind anomalous heating remain undetermined. Here we show how a two-ion probe displays a transition in its dissipation properties, enabling experimental access to the mean orientation of the dipoles and the spatial extent of dipole-dipole correlations. This information can be used to test the validity of candidate microscopic models, which predict correlation lengths spanning several orders of magnitude. Furthermore, we propose an experiment to measure these effects with currently available traps and techniques.

  11. Limits on the ions temperature anisotropy in turbulent intracluster medium

    Energy Technology Data Exchange (ETDEWEB)

    Santos-Lima, R. [Deutsches Elektronen-Synchrotron (DESY), Zeuthen (Germany); Potsdam Univ. (Germany). Inst. fuer Physik und Astronomie; Univ. de Sao Paulo (Brazil). Inst. de Astronomia, Geofisica e Ciencias Atmosfericas; Yan, H. [Deutsches Elektronen-Synchrotron (DESY), Zeuthen (Germany); Potsdam Univ. (Germany). Inst. fuer Physik und Astronomie; Gouveia Dal Pino, E.M. de [Univ. de Sao Paulo (Brazil). Inst. de Astronomia, Geofisica e Ciencias Atmosfericas; Lazarian, A. [Wisconsin Univ., Madison, WI (United States). Dept. of Astronomy

    2016-05-15

    Turbulence in the weakly collisional intracluster medium of galaxies (ICM) is able to generate strong thermal velocity anisotropies in the ions (with respect to the local magnetic field direction), if the magnetic moment of the particles is conserved in the absence of Coulomb collisions. In this scenario, the anisotropic pressure magnetohydrodynamic (AMHD) turbulence shows a very different statistical behaviour from the standard MHD one and is unable to amplify seed magnetic fields, in disagreement with previous cosmological MHD simulations which are successful to explain the observed magnetic fields in the ICM. On the other hand, temperature anisotropies can also drive plasma instabilities which can relax the anisotropy. This work aims to compare the relaxation rate with the growth rate of the anisotropies driven by the turbulence. We employ quasilinear theory to estimate the ions scattering rate due to the parallel firehose, mirror, and ion-cyclotron instabilities, for a set of plasma parameters resulting from AMHD simulations of the turbulent ICM. We show that the ICM turbulence can sustain only anisotropy levels very close to the instabilities thresholds. We argue that the AMHD model which bounds the anisotropies at the marginal stability levels can describe the Alfvenic turbulence cascade in the ICM.

  12. Electron cyclotron resonance heating by magnetic filter field in a negative hydrogen ion source

    Energy Technology Data Exchange (ETDEWEB)

    Kim, June Young, E-mail: beacoolguy@snu.ac.kr; Cho, Won-Hwi; Dang, Jeong-Jeung; Chung, Kyoung-Jae, E-mail: jkjlsh1@snu.ac.kr; Hwang, Y. S. [Department of Nuclear Engineering, Seoul National University, Seoul 151-742 (Korea, Republic of)

    2016-02-15

    The influence of magnetic filter field on plasma properties in the heating region has been investigated in a planar-type inductively coupled radio-frequency (RF) H{sup −} ion source. Besides filtering high energy electrons near the extraction region, the magnetic filter field is clearly observed to increase the electron temperature in the heating region at low pressure discharge. With increasing the operating pressure, enhancement of electron temperature in the heating region is reduced. The possibility of electron cyclotron resonance (ECR) heating in the heating region due to stray magnetic field generated by a filter magnet located at the extraction region is examined. It is found that ECR heating by RF wave field in the discharge region, where the strength of an axial magnetic field is approximately ∼4.8 G, can effectively heat low energy electrons. Depletion of low energy electrons in the electron energy distribution function measured at the heating region supports the occurrence of ECR heating. The present study suggests that addition of axial magnetic field as small as several G by an external electromagnet or permanent magnets can greatly increase the generation of highly ro-vibrationally excited hydrogen molecules in the heating region, thus improving the performance of H{sup −} ion generation in volume-produced negative hydrogen ion sources.

  13. Operational Experience with The GTS-LHC Ion Source and Future Developments of The CERN Ion Injector

    CERN Document Server

    Kuchler, D; Lombardi, A; O'Neil, M; Scrivens, R; Stafford-Haworth, J; Thomae, R

    2012-01-01

    Since 2010 the GTS-LHC source delivers lead ions for heavy ion physics at the LHC. Several modifications allowed the improvement the source reliability and the beam stability. The attempts to improve the beam intensity were less successful. The different modifications and actual performance figures will be presented in this paper. In addition to the heavy ion physics program of the LHC new ion species will be requested for different experiments in the future. The fixed target experiment NA61 requires primary argon and xenon beams. And a future biomedical facility asks for light ions in the range helium to neon. Approaches to prepare these beams and to modify the ion injector towards a light ion front end are presented.

  14. Recent developments of ion sources for life-science studies at the Heavy Ion Medical Accelerator in Chiba (invited).

    Science.gov (United States)

    Kitagawa, A; Drentje, A G; Fujita, T; Muramatsu, M; Fukushima, K; Shiraishi, N; Suzuki, T; Takahashi, K; Takasugi, W; Biri, S; Rácz, R; Kato, Y; Uchida, T; Yoshida, Y

    2016-02-01

    With about 1000-h of relativistic high-energy ion beams provided by Heavy Ion Medical Accelerator in Chiba, about 70 users are performing various biology experiments every year. A rich variety of ion species from hydrogen to xenon ions with a dose rate of several Gy/min is available. Carbon, iron, silicon, helium, neon, argon, hydrogen, and oxygen ions were utilized between 2012 and 2014. Presently, three electron cyclotron resonance ion sources (ECRISs) and one Penning ion source are available. Especially, the two frequency heating techniques have improved the performance of an 18 GHz ECRIS. The results have satisfied most requirements for life-science studies. In addition, this improved performance has realized a feasible solution for similar biology experiments with a hospital-specified accelerator complex.

  15. Wide-Temperature Electrolytes for Lithium-Ion Batteries

    Energy Technology Data Exchange (ETDEWEB)

    Li, Qiuyan; Jiao, Shuhong; Luo, Langli; Ding, Michael S.; Zheng, Jianming; Cartmell, Samuel S.; Wang, Chong-Min; Xu, Kang; Zhang, Ji-Guang; Xu, Wu

    2017-05-26

    Formulating electrolytes with solvents of low freezing points and high dielectric constants is a direct approach to extend the service temperature range of lithium (Li)-ion batteries (LIBs), for which propylene carbonate (PC), ethyl methyl carbonate (EMC), diethyl carbonate (DEC), methyl butyrate (MB) are excellent candidates. In this work, we report such low temperature electrolyte formulations by optimizing the content of ethylene carbonate (EC) in the EC-PC-EMC ternary solvent system with LiPF6 salt and CsPF6 additive. An extended service temperature range from 40°C to 60°C was obtained in LIBs with lithium nickel cobalt aluminum mixed oxide (LiNi0.80Co0.15Al0.05O2, NCA) as cathode and graphite as anode. The discharge capacities at low temperatures and the cycle life at room and elevated temperatures were systematically investigated in association with the ionic conductivity and phase transition behaviors. The most promising electrolyte formulation was identified as 1.0 M LiPF6 in EC-PC-EMC (1:1:8 by wt.) with 0.05 M CsPF6, which was demonstrated in both coin cells of graphite||NCA and 1 Ah pouch cells of graphite||LiNi1/3Mn1/3Co1/3O2. This optimized electrolyte enables excellent wide-temperature performances, as evidenced by the 68% capacity retention at 40C and C/5 rate, and nearly identical stable cycle life at room and elevated temperatures up to 60C.

  16. Status report of the multipurpose superconducting electron cyclotron resonance ion source

    NARCIS (Netherlands)

    Ciavola, G.; Gammino, S.; Barbarino, S.; Celona, L.; Consoli, F.; Gallo, G.; Maimone, F.; Mascali, D.; Passarello, S.; Galata, A.; Tinschert, K.; Spaedtke, P.; Lang, R.; Maeder, J.; Rossbach, J.; Koivisto, H.; Savonen, M.; Koponen, T.; Suominen, P.; Ropponen, T.; Barue, C.; Lechartier, M.; Beijers, J. P. M.; Brandenburg, S.; Kremers, H. R.; Vanrooyen, D.; Kuchler, D.; Scrivens, R.; Schachter, L.; Dobrescu, S.; Stiebing, K.

    Intense heavy ion beam production with electron cyclotron resonance (ECR) ion sources is a common requirement for many of the accelerators under construction in Europe and elsewhere. An average increase of about one order of magnitude per decade in the performance of ECR ion sources was obtained up

  17. Techniques and mechanisms applied in electron cyclotron resonance sources for highly charged ions

    NARCIS (Netherlands)

    Drentje, AG

    Electron cyclotron resonance ion sources are delivering beams of highly charged ions for a wide range of applications in many laboratories. For more than two decades, the development of these ion sources has been to a large extent an intuitive and experimental enterprise. Much effort has been spent

  18. Effect of swirling desolvation gas flow in an atmospheric pressure ion source.

    Science.gov (United States)

    Savtchenko, Serguei; Ashgriz, Nasser; Jolliffe, Chuck; Cousins, Lisa; Gamble, Heather

    2014-09-01

    A numerical study is performed to examine the effect of introducing a swirling desolvation gas flow on the flow transport characteristics in an electrospray and an atmospheric pressure chemical ionization (APCI) system. An ion source having three coaxial tubes is considered: (1) an inner capillary tube to inject the liquid sample, (2) a center coaxial tube to provide a room temperature gas flow to nebulize the liquid, referred to as the nebulizing gas flow, and (3) an outer coaxial tube having a converging exit to supply a high temperature gas for droplet desolvation, referred to as the desolvation gas flow. The results show that a swirling desolvation gas flow reduces the dispersion of the nebulizing gas and suppresses turbulent diffusion. The effect of swirling desolvation flow on the trajectory of a range of droplet sizes emitted from a source is also considered.

  19. Universal main magnetic focus ion source: A new tool for laboratory research of astrophysics and Tokamak microplasma

    Science.gov (United States)

    Ovsyannikov, V. P.; Nefiodov, A. V.; Levin, A. A.

    2017-01-01

    A novel room-temperature ion source for the production of atomic ions in electron beam within wide ranges of electron energy and current density is developed. The device can operate both as conventional Electron Beam Ion Source/Trap (EBIS/T) and novel Main Magnetic Focus Ion Source. The ion source is suitable for generation of the low-, medium- and high-density microplasma in steady state, which can be employed for investigation of a wide range of physical problems in ordinary university laboratory, in particular, for microplasma simulations relevant to astrophysics and ITER reactor. For the electron beam characterized by the incident energy Ee = 10 keV, the current density je ˜ 20 kA/cm2 and the number density ne ˜ 2 × 1013 cm-3 were achieved experimentally. For Ee ˜ 60 keV, the value of electron number density ne ˜ 1014 cm-3 is feasible. The efficiency of the novel ion source for laboratory astrophysics significantly exceeds that of other existing warm and superconducting EBITs.

  20. Source-to-target simulation of simultaneous longitudinal and transverse focusing of heavy ion beams

    Directory of Open Access Journals (Sweden)

    D. R. Welch

    2008-06-01

    Full Text Available Longitudinal bunching factors in excess of 70 of a 300-keV, 27-mA K^{+} ion beam have been demonstrated in the neutralized drift compression experiment [P. K. Roy et al., Phys. Rev. Lett. 95, 234801 (2005PRLTAO0031-900710.1103/PhysRevLett.95.234801] in rough agreement with particle-in-cell source-to-target simulations. A key aspect of these experiments is that a preformed plasma provides charge neutralization of the ion beam in the last one meter drift region where the beam perveance becomes large. The simulations utilize the measured ion source temperature, diode voltage, and induction-bunching-module voltage waveforms in order to determine the initial beam longitudinal phase space which is critical to accurate modeling of the longitudinal compression. To enable simultaneous longitudinal and transverse compression, numerical simulations were used in the design of the solenoidal focusing system that compensated for the impact of the applied velocity tilt on the transverse phase space of the beam. Complete source-to-target simulations, that include detailed modeling of the diode, magnetic transport, induction bunching module, and plasma neutralized transport, were critical to understanding the interplay between the various accelerator components in the experiment. Here, we compare simulation results with the experiment and discuss the contributions to longitudinal and transverse emittance that limit the final compression.

  1. Effect of pulse-modulated microwaves on fullerene ion production with electron cyclotron resonance ion source.

    Science.gov (United States)

    Asaji, T; Uchida, T; Minezaki, H; Oshima, K; Racz, R; Muramatsu, M; Biri, S; Kitagawa, A; Kato, Y; Yoshida, Y

    2012-02-01

    Fullerene plasmas generated by pulse-modulated microwaves have been investigated under typical conditions at the Bio-Nano electron cyclotron resonance ion source. The effect of the pulse modulation is distinct from that of simply structured gases, and then the density of the fullerene plasmas increased as decreasing the duty ratio. The density for a pulse width of 10 μs at the period of 100 μs is 1.34 times higher than that for CW mode. We have studied the responses of fullerene and argon plasmas to pulsed microwaves. After the turnoff of microwave power, fullerene plasmas lasted ∼30 times longer than argon plasmas.

  2. Particle model of a cylindrical inductively coupled ion source

    Science.gov (United States)

    Ippolito, N. D.; Taccogna, F.; Minelli, P.; Cavenago, M.; Veltri, P.

    2017-08-01

    In spite of the wide use of RF sources, a complete understanding of the mechanisms regulating the RF-coupling of the plasma is still lacking so self-consistent simulations of the involved physics are highly desirable. For this reason we are developing a 2.5D fully kinetic Particle-In-Cell Monte-Carlo-Collision (PIC-MCC) model of a cylindrical ICP-RF source, keeping the time step of the simulation small enough to resolve the plasma frequency scale. The grid cell dimension is now about seven times larger than the average Debye length, because of the large computational demand of the code. It will be scaled down in the next phase of the development of the code. The filling gas is Xenon, in order to minimize the time lost by the MCC collision module in the first stage of development of the code. The results presented here are preliminary, with the code already showing a good robustness. The final goal will be the modeling of the NIO1 (Negative Ion Optimization phase 1) source, operating in Padua at Consorzio RFX.

  3. Immobilized aptamer paper spray ionization source for ion mobility spectrometry.

    Science.gov (United States)

    Zargar, Tahereh; Khayamian, Taghi; Jafari, Mohammad T

    2017-01-05

    A selective thin-film microextraction based on aptamer immobilized on cellulose paper was used as a paper spray ionization source for ion mobility spectrometry (PSI-IMS), for the first time. In this method, the paper is not only used as an ionization source but also it is utilized for the selective extraction of analyte, based on immobilized aptamer. This combination integrates both sample preparation and analyte ionization in a Whatman paper. To that end, an appropriate sample introduction system with a novel design was constructed for the paper spray ionization source. Using this system, a continuous solvent flow works as an elution and spray solvent simultaneously. In this method, analyte is adsorbed on a triangular paper with immobilized aptamer and then it is desorbed and ionized by elution solvent and applied high voltage on paper, respectively. The effects of different experimental parameters such as applied voltage, angle of paper tip, distance between paper tip and counter electrode, elution solvent type, and solvent flow rate were optimized. The proposed method was exhaustively validated in terms of sensitivity and reproducibility by analyzing the standard solutions of codeine and acetamiprid. The analytical results obtained are promising enough to ensure the use of immobilized aptamer paper-spray as both the extraction and ionization techniques in IMS for direct analysis of biomedicine. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Relativistic ion collisions as the source of hypernuclei

    Energy Technology Data Exchange (ETDEWEB)

    Botvina, A.S. [J.W. Goethe University, Frankfurt Institute for Advanced Studies, Frankfurt am Main (Germany); Russian Academy of Sciences, Institute for Nuclear Research, Moscow (Russian Federation); Bleicher, M.; Steinheimer, J. [J.W. Goethe University, Frankfurt Institute for Advanced Studies, Frankfurt am Main (Germany); Pochodzalla, J. [J. Gutenberg-Universitaet, Helmholtz-Institut Mainz, Mainz (Germany); J. Gutenberg-Universitaet Mainz, Institut fuer Kernphysik and PRISMA Cluster of Excellence, Mainz (Germany)

    2016-08-15

    We shortly review the theory of hypernuclei production in relativistic ion collisions, that is adequate to future experiments at BM rate at N, NICA, and FAIR. Within a hybrid approach we use transport, coalescence and statistical models to describe the whole process. We demonstrate that the origin of hypernuclei can be explained by typical baryon interactions, that is similar to the production of conventional nuclei. In particular, heavy hypernuclei are coming mostly from projectile and target residues, whereas light hypernuclei can be produced at all rapidities. The yields of hypernuclei increase considerably above the energy threshold for Λ hyperon production, and there is a tendency to saturation of yields of hypernuclei with increasing the beam energy up to few TeV. There are unique opportunities in relativistic ion collisions which are difficult to realize in traditional hypernuclear experiments: The produced hypernuclei have a broad distribution in masses and isospin. They can even reach beyond the neutron and proton drip-lines and that opens a chance to investigate properties of exotic hypernuclei. One finds also the abundant production of multi-strange nuclei, of bound and unbound hypernuclear states with new decay modes. In addition, we can directly get an information on the hypermatter both at high and low temperatures. (orig.)

  5. Review of ISOL target-ion-source systems

    CERN Document Server

    Kirchner, R

    2003-01-01

    Any review of target-ion-source systems (TISS) is necessarily a variation of the ISOL-theme 'efficient, fast, selective'. In the first part, more than 30 years of TISS development are examined in view of these key characteristics. By looking at the lines of development that were successful, at the lines that were abandoned (partly for good, partly for less good reasons), the lines with the most promising perspectives emerge. The second part deals with on-line chemistry in the TISS and its possibly double benefits: enhanced selectivity or increased separation speed, or both in favourable cases, as the relatively new sulfide chemistry. For the group-IVa-elements germanium and tin, the separation as sulfide-ions does not only suppress strongly the contamination by the neighbouring elements. It also reduces the effusion part of the release by orders of magnitude to the level of the intrinsic delay caused by molecular flow. The homologue chemistry is likely to work for silicon, but not for lead. While selectivity ...

  6. Performance of a corona ion source for measurement of sulfuric acid by chemical ionization mass spectrometry

    Directory of Open Access Journals (Sweden)

    A. Kürten

    2011-03-01

    Full Text Available The performance of an ion source based on corona discharge has been studied. This source is used for the detection of gaseous sulfuric acid by chemical ionization mass spectrometry (CIMS through the reaction of NO3 ions with H2SO4. The ion source is operated under atmospheric pressure and its design is similar to the one of a radioactive (americium-241 ion source which has been used previously. The results show that the detection limit for the corona ion source is sufficiently good for most applications. For an integration time of 1 min it is ~6 × 104 molecule cm−3 of H2SO4. In addition, only a small cross-sensitivity to SO2 has been observed for concentrations as high as 1 ppmv in the sample gas. This low sensitivity to SO2 is achieved even without the addition of an OH scavenger. When comparing the new corona ion source with the americium ion source for the same provided H2SO4 concentration, both ion sources yield almost identical values. These features make the corona ion source investigated here favorable over the more commonly used radioactive ion sources for most applications where H2SO4 is measured by CIMS.

  7. Modelling RF-plasma interaction in ECR ion sources

    Science.gov (United States)

    Mascali, David; Torrisi, Giuseppe; Galatà, Alessio; Sorbello, Gino; Castro, Giuseppe; Celona, Luigi; Lega, Lorenzo; Leonardi, Ornella; Mazzaglia, Maria; Naselli, Eugenia; Neri, Lorenzo; Gammino, Santo

    2017-10-01

    This paper describes three-dimensional self-consistent numerical simulations of wave propagation in magnetoplasmas of Electron cyclotron resonance ion sources (ECRIS). Numerical results can give useful information on the distribution of the absorbed RF power and/or efficiency of RF heating, especially in the case of alternative schemes such as mode-conversion based heating scenarios. Ray-tracing approximation is allowed only for small wavelength compared to the system scale lengths: as a consequence, full-wave solutions of Maxwell-Vlasov equation must be taken into account in compact and strongly inhomogeneous ECRIS plasmas. This contribution presents a multi-scale temporal domains approach for simultaneously including RF dynamics and plasma kinetics in a "cold-plasma", and some perspectives for "hot-plasma" implementation. The presented results rely with the attempt to establish a modal-conversion scenario of OXB-type in double frequency heating inside an ECRIS testbench.

  8. RF Plasma modeling of the Linac4 H− ion source

    CERN Document Server

    Mattei, S; Hatayama, A; Lettry, J; Kawamura, Y; Yasumoto, M; Schmitzer, C

    2013-01-01

    This study focuses on the modelling of the ICP RF-plasma in the Linac4 H− ion source currently being constructed at CERN. A self-consistent model of the plasma dynamics with the RF electromagnetic field has been developed by a PIC-MCC method. In this paper, the model is applied to the analysis of a low density plasma discharge initiation, with particular interest on the effect of the external magnetic field on the plasma properties, such as wall loss, electron density and electron energy. The use of a multi-cusp magnetic field effectively limits the wall losses, particularly in the radial direction. Preliminary results however indicate that a reduced heating efficiency results in such a configuration. The effect is possibly due to trapping of electrons in the multi-cusp magnetic field, preventing their continuous acceleration in the azimuthal direction.

  9. Modelling RF-plasma interaction in ECR ion sources

    Directory of Open Access Journals (Sweden)

    Mascali David

    2017-01-01

    Full Text Available This paper describes three-dimensional self-consistent numerical simulations of wave propagation in magnetoplasmas of Electron cyclotron resonance ion sources (ECRIS. Numerical results can give useful information on the distribution of the absorbed RF power and/or efficiency of RF heating, especially in the case of alternative schemes such as mode-conversion based heating scenarios. Ray-tracing approximation is allowed only for small wavelength compared to the system scale lengths: as a consequence, full-wave solutions of Maxwell-Vlasov equation must be taken into account in compact and strongly inhomogeneous ECRIS plasmas. This contribution presents a multi-scale temporal domains approach for simultaneously including RF dynamics and plasma kinetics in a “cold-plasma”, and some perspectives for “hot-plasma” implementation. The presented results rely with the attempt to establish a modal-conversion scenario of OXB-type in double frequency heating inside an ECRIS testbench.

  10. Diagnostics of a charge breeder electron cyclotron resonance ion source helium plasma with the injection of ^{23}Na^{1+} ions

    Directory of Open Access Journals (Sweden)

    O. Tarvainen

    2016-05-01

    Full Text Available This work describes the utilization of an injected ^{23}Na^{1+} ion beam as a diagnostics of the helium plasma of a charge breeder electron cyclotron resonance ion source. The obtained data allows estimating the upper limit for the ion-ion collision mean-free path of the incident sodium ions, the lower limit of ion-ion collision frequencies for all charge states of the sodium ions and the lower limit of the helium plasma density. The ion-ion collision frequencies of high charge state ions are shown to be at least on the order of 1–10 MHz and the plasma density is estimated to be on the order of 10^{11}  cm^{-3} or higher. The experimental results are compared to simulations of the ^{23}Na^{1+} capture into the helium plasma. The results indicate that the lower breeding efficiency of light ions in comparison to heavier elements is probably due to different capture efficiencies in which the in-flight ionization of the incident 1+ ions plays a vital role.

  11. Charge Breeding of Radioactive Ions in an Electron Cyclotron Resonance Ion Source(ECRIS) at ISOLDE

    CERN Multimedia

    Lindroos, M

    2002-01-01

    The development of an efficient charge breeding scheme for the next generation of RIB facilities will have a strong impact on the post-accelerator for several Radioactive Ion Beam (RIB) projects at European large scale facilities. At ISOLDE/CERN there will be the unique possibility to carry out experiments with the two possible charge breeding set-ups with a large variety of radioactive isotopes using identical injection conditions. One charge breeding set-up is the Penning trap/EBIS combination which feeds the REX-ISOLDE linear accelerator and which is in commissioning now. The second charge breeder is a new ECRIS PHOENIX developed at the ISN ion source laboratory at Grenoble. This ECRIS is now under investigation with a 14 GHz amplifier to characterize its performance. The experiments are accompanied by theoretical studies in computer simulations in order to optimize the capture of the ions in the ECRIS plasma. A second identical PHOENIX ECRIS which is under investigation at the Daresbury Laboratory is avai...

  12. An ion species model for positive ion sources - part I description of the model

    CERN Document Server

    Surrey, E

    2014-01-01

    A one dimensional model of the magnetic multipole volume plasma source has been developed for use in intense ion/neutral atom beam injectors. The model uses plasma transport coefficients for particle and energy flow to create a detailed description of the plasma parameters along an axis parallel to that of the extracted beam. Primarily constructed for applications to neutral beam injection systems on fusion devices, the model concentrates on the hydrogenic isotopes but can be extended to any gas by substitution of the relevant masses, cross sections and rate coefficients. The model considers the flow of fast ionizing electrons that create the ratios of the three hydrogenic isotope ion species, H+, H2 +, H3 + (and similarly for deuterium and tritium) as they flow towards the beam extraction electrode, together with the production of negative hydrogenic ions through volume processes. The use of detailed energy balance in the discharge allows the determination of the fraction of the gas density that is in an ato...

  13. Effects of ion source operating parameters on direct analysis in real time of 18 active components from traditional Chinese medicine.

    Science.gov (United States)

    Wang, Lu; Zeng, Shanshan; Qu, Haibin

    2016-03-20

    Direct analysis in real time mass spectrometry (DART-MS) provides a new analytical method for traditional Chinese medicine (TCM). The present study investigated the effects of key ion source operating parameters on DART-MS analysis of various TCM active components. A total of 18 active components, including phenylpropanoids, alkaloids, saponins, flavones, volatile oils, and glycosides, were examined. For each substance, the peak area and signal-to-noise of its characteristic ions under different reagent gases and heater temperatures were compared. Based on the comparison, the relationships among chemical structures, ion source parameters and instrument responses were revealed. Finally, some suggestions about choosing reagent gas and heater temperature were proposed for types of TCM active substance, which offered a reference for the application of DART-MS on TCM analysis. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. A New 14 GHz ECR Ion Source for the Heavy Ion Accelerator Facility ATLAS

    Science.gov (United States)

    Schlapp, M.; Vondrasek, R. C.; Szczech, J.; Billquist, P. J.; Pardo, R. C.; Xie, Z. Q.; Harkewicz, R.

    1997-05-01

    A new 14 GHz ECRIS has been designed and built over the last two years. The source design incorporates the latest results from ECR developments to produce intense beams of highly charged ions, i.e. an improved magnetic electron confinement. The aluminum plasma chamber and extraction electrode as well as a biased disk on axis at the microwave injection side donate additional electrons to the plasma, making use of the large secondary electron yield from aluminum oxide. The source will be capable of ECR plasma heating using two different frequencies simultaneously to increase the electron energy gain for the production of high charge states. To be able to deliver usable intensities of the heaviest ion beams the design will also allow axial access for metal evaporation ovens and solid material samples. The main design goal is to produce several eμA of at least ^238U^34+ in order to accelerate the beam to coulomb-barrier energies without further stripping. That should also significantly improve the beam quality over beams requiring stripping for acceleration. This work was supported by US D.O.E. Nuclear Physics Division under contract W-31-109-ENG-38.

  15. Diamond-Like Carbon Film Deposition Using DC Ion Source with Cold Hollow Cathode

    Directory of Open Access Journals (Sweden)

    E. F. Shevchenko

    2014-01-01

    Full Text Available Carbon diamond-like thin films on a silicon substrate were deposited by direct reactive ion beam method with an ion source based on Penning direct-current discharge system with cold hollow cathode. Deposition was performed under various conditions. The pressure (12–200 mPa and the plasma-forming gas composition consisting of different organic compounds and hydrogen (C3H8, CH4, Si(CH32Cl2, H2, the voltage of accelerating gap in the range 0.5–5 kV, and the substrate temperature in the range 20–850°C were varied. Synthesized films were researched using nanoindentation, Raman, and FTIR spectroscopy methods. Analysis of the experimental results was made in accordance with a developed model describing processes of growth of the amorphous and crystalline carbon materials.

  16. Operation modes of the FALCON ion source as a part of the AMS cluster tool

    Directory of Open Access Journals (Sweden)

    Girka Oleksii

    2015-06-01

    Full Text Available The paper investigates the options to increase the production yield of temperature compensated surface acoustic wave (SAW devices with a defined range of operational frequencies. The paper focuses on the preparation of large wafers with SiO2 and AlN/Si3N4 depositions. Stability of the intermediate SiO2 layer is achieved by combining high power density UV radiation with annealing in high humidity environment. A uniform thickness of the capping AlN layer is achieved by local high-rate etching with a focused ion beam emitted by the FALCON ion source. Operation parameters and limitations of the etching process are discussed.

  17. High efficiency noble gas electron impact ion source for isotope separation

    Energy Technology Data Exchange (ETDEWEB)

    Appelhans, A. D. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Olson, J. E. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Dahl, D. A. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Ward, M. B. [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2016-07-01

    An electron impact ion source has been designed for generation of noble gas ions in a compact isotope separator. The source utilizes a circular filament that surrounds an ionization chamber, enabling multiple passes of electrons through the ionization chamber. This report presents ion optical design and the results of efficiency and sensitivity measurements performed in an ion source test chamber and in the compact isotope separator. The cylindrical design produced xenon ions at an efficiency of 0.37% with a sensitivity of ~24 µA /Pa at 300 µA of electron current.

  18. Simulation of RF power and multi-cusp magnetic field requirement for H- ion sources

    Science.gov (United States)

    Pathak, Manish; Senecha, V. K.; Kumar, Rajnish; Ghodke, Dharmraj. V.

    2016-12-01

    A computer simulation study for multi-cusp RF based H- ion source has been carried out using energy and particle balance equation for inductively coupled uniformly dense plasma considering sheath formation near the boundary wall of the plasma chamber for RF ion source used as high current injector for 1 Gev H- Linac project for SNS applications. The average reaction rates for different reactions responsible for H- ion production and destruction have been considered in the simulation model. The RF power requirement for the caesium free H- ion source for a maximum possible H- ion beam current has been derived by evaluating the required current and RF voltage fed to the coil antenna using transformer model for Inductively Coupled Plasma (ICP). Different parameters of RF based H- ion source like excited hydrogen molecular density, H- ion density, RF voltage and current of RF antenna have been calculated through simulations in the presence and absence of multicusp magnetic field to distinctly observe the effect of multicusp field. The RF power evaluated for different H- ion current values have been compared with the experimental reported results showing reasonably good agreement considering the fact that some RF power will be reflected from the plasma medium. The results obtained have helped in understanding the optimum field strength and field free regions suitable for volume emission based H- ion sources. The compact RF ion source exhibits nearly 6 times better efficiency compare to large diameter ion source.

  19. Improvement of a plasma uniformity of the 2nd ion source of KSTAR neutral beam injector.

    Science.gov (United States)

    Jeong, S H; Kim, T S; Lee, K W; Chang, D H; In, S R; Bae, Y S

    2014-02-01

    The 2nd ion source of KSTAR (Korea Superconducting Tokamak Advanced Research) NBI (Neutral Beam Injector) had been developed and operated since last year. A calorimetric analysis revealed that the heat load of the back plate of the ion source is relatively higher than that of the 1st ion source of KSTAR NBI. The spatial plasma uniformity of the ion source is not good. Therefore, we intended to identify factors affecting the uniformity of a plasma density and improve it. We estimated the effects of a direction of filament current and a magnetic field configuration of the plasma generator on the plasma uniformity. We also verified that the operation conditions of an ion source could change a uniformity of the plasma density of an ion source.

  20. Adsorption of divalent lead ions by zeolites and activated carbon: effects of pH, temperature, and ionic strength.

    Science.gov (United States)

    Payne, Kelly B; Abdel-Fattah, Tarek M

    2004-01-01

    Lead alloy bullets used at the 2600 military small arm ranges and 9000 nonmilitary outdoor shooting ranges in the United States are a source of mobilized lead ions under conditions of low pH, significant changes in ionic strength, changes in the reduction oxidation potential (redox), and through binding metal ions to soil organic matter. Once mobile, these lead ions can contaminate adjacent soil and water. Batch adsorption kinetic and isotherm studies were conducted to compare and evaluate different types of adsorbents for lead ion removal from aqueous media. The effects on lead ion absorption from pH changes, competing ions, and temperature increases were also investigated. Adsorbent materials such as activated carbon and naturally occurring zeolites (clinoptilolite and chabazite) were selected because of their relative low cost and because the zeolites are potential point-of-use materials for mitigating wastewater runoff. Molecular sieves, Faujasite (13X) and Linde type A (5A) were selected because they provide a basis for comparison with previous studies and represent well-characterized materials. The relative rate for lead ion adsorption was: 13X > chabazite > clinoptilolite > 5A > activated carbon. Modeling lead ion adsorption by these adsorbents using the Langmuir and Freundlich isotherm expressions determined the adsorbents' capacity for lead ion removal from aqueous media. 13X, 5A, and activated carbon best fit the Langmuir isotherm expression; chabazite and clinoptilolite best fit the Freundlich isotherm. Applications of chabazite would require pH values between 4 and 11, clinoptilolite between 3 and 11, while activated carbon would operate at a pH above 7. Ionic competition reduced lead ion removal by the zeolites, but enhanced activated carbon performance. Increasing temperature improved adsorption performance for the zeolites; activated carbon lead ion adsorption was temperature independent.

  1. A Phase I Program to Improve Low Temperature Performance of Lithium-Ion Batteries Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Lithium-ion (Li-ion) batteries are attractive candidates for use as power sources in aerospace applications because they have high specific energy ( up to 200 Wh/kg)...

  2. Development of an 18 GHz superconducting electron cyclotron resonance ion source at RCNP.

    Science.gov (United States)

    Yorita, Tetsuhiko; Hatanaka, Kichiji; Fukuda, Mitsuhiro; Kibayashi, Mitsuru; Morinobu, Shunpei; Okamura, Hiroyuki; Tamii, Atsushi

    2008-02-01

    An 18 GHz superconducting electron cyclotron resonance ion source has recently been developed and installed in order to extend the variety and the intensity of ions at the RCNP coupled cyclotron facility. Production of several ions such as O, N, Ar, Kr, etc., is now under development and some of them have already been used for user experiments. For example, highly charged heavy ion beams like (86)Kr(21+,23+) and intense (16)O(5+,6+) and (15)N(6+) ion beams have been provided for experiments. The metal ion from volatile compounds method for boron ions has been developed as well.

  3. Ion source developments for the production of radioactive isotope beams at TRIUMF

    Energy Technology Data Exchange (ETDEWEB)

    Ames, F., E-mail: ames@triumf.ca; Bricault, P.; Heggen, H.; Kunz, P.; Lassen, J.; Mjøs, A.; Raeder, S.; Teigelhöfer, A. [TRIUMF, 4004 Wesbrook Mall, Vancouver, British Columbia V6T2A3 (Canada)

    2014-02-15

    At the ISAC facility at TRIUMF radioactive ions are produced by bombarding solid targets with up to 100 μA of 500 MeV protons. The reaction products have to diffuse out of the hot target into an ion source. Normally, singly charged ions are extracted. They can be transported either directly to experiments or via an ECR charge state breeder to a post accelerator. Several different types of ion sources have to be used in order to deliver a large variety of rare isotope beams. At ISAC those are surface ion sources, forced electron beam arc discharge (FEBIAD) ion sources and resonant laser ionization sources. Recent development activities concentrated on increasing the selectivity for the ionization to suppress isobaric contamination in the beam. Therefore, a surface ion rejecting resonant laser ionization source (SIRLIS) has been developed to suppress ions from surface ionization. For the FEBIAD ion source a cold transfer line has been introduced to prevent less volatile components from reaching the ion source.

  4. Beam Current Increase and Cathode Lifetime Improvement of KOTRON-13 Ion Source

    Energy Technology Data Exchange (ETDEWEB)

    Lee, W. K.; Chae, S. K.; Song, J. Y.; Im, G. S.; Cho, B. O. [Samyoung Unitech Co., Seoul (Korea, Republic of)

    2010-05-15

    Technology of cyclotron has been actively developed to meet the increasing requirement output of medical radioactive isotopes for PET. KOTRON-13 is produced with low negative hydrogen ion beam current owing to the low efficiency of proton beam current compared with foreign cyclotron. In the defect there from, the lifetime of cathode is around 5,000min, which requires frequent maintenance period, and the target beam current is maximum 50uA at a poor efficiency compared with the inflow quantity of hydrogen gas and that of inflicting arc current. Considering above affairs, we have to improve the PIG ion source extraction efficiency of KOTRON-13 in order to lift beam current. Mostly the ion source of cyclotron less than 30Mev comes from the use of PIG ion source mainly with the method of cold cathode or hot cathode. However, the cyclotron of 30Mev grade of EBCO or IBA uses the external ion source and uses ion source with cusp type of good withdrawal efficiency. This type requires high voltage, and transports ion from ion source to cyclotron, which requires precise transportation equipment. And entering cyclotron requires a high quality of inflictor with a high defect rate, but high current cyclotron has no choice but to use ion source of such a method. But the cyclotron using PET with the beam current less than 100uA uses PIG ion source of KOTRON-13 with a reasonable maintenance cost

  5. Advances in surface ion suppression from RILIS: Towards the Time-of-Flight Laser Ion Source (ToF-LIS)

    CERN Document Server

    Rothe, S; Crepieux, B; Day Goodacre, T; Fedosseev, V N; Giles, T; Marsh, B A; Ramos, J P; Rossel, R E

    2016-01-01

    We present results from the development towards the Time-of-Flight Laser Ion Source (ToF-LIS) aiming for the suppression of isobaric contaminants through fast beam gating. The capability to characterize high resistance ion sources has been successfully demonstrated. A ninefold selectivity gain has been achieved through suppression of surface ionized potassium, while maintaining >90% transmission for laser-ionized gallium using a thin wall graphite ionizer cavity combined with a fast beam gate. Initial results from the investigation of glassy carbon as a potential hot cavity ion source are presented. Power-cycle tests of a newly designed mount for fragile ion source cavities indicates its capability to survive the thermal stress expected during operation in an ISOLDE target unit. Finally, we introduce fast ion beam switching at a rate of 10 kHz using the ISOLDE ion beam switchyard as a new concept for ion beam distribution and conclude by highlighting the potential applications of this ion beam multiplexing te...

  6. Measurements of ion energies during plasma heating of the Proto-MPEX High Intensity Plasma Source

    Science.gov (United States)

    Caughman, J. B. O.; Goulding, R. H.; Biewer, T. M.; Bigelow, T. S.; Caneses, J.; Diem, S. J.; Green, D. L.; Isler, R. C.; Rapp, J.; Piotrowicz, P.; Beers, C. J.; Kafle, N.; Showers, M. A.

    2017-10-01

    The Prototype Materials Plasma Exposure eXperiment (Proto-MPEX) is a linear high-intensity RF plasma source that combines a high-density helicon plasma generator with ion and electron heating sections. It is being used to study the physics of heating over-dense plasmas in a linear configuration with the goal of delivering a plasma heat flux of 10 MW/m2 at a target. The helicon plasma is produced by coupling 13.56 MHz RF power at levels >100 kW. Additional heating is provided by ion cyclotron heating (ICH) ( 25 kW) and electron Bernstein wave (EBW) heating ( 25 kW) at 28 GHz. Measurements of the ion energy distribution with a retarding field energy analyzer (RFEA) show an increase in ion energies in the edge of the plasma when ICH is applied, which is consistent with COMSOL modeling of the power deposition from the antenna. Views of the target plate with an infrared camera show an increase in the surface temperature at large radii during ICH, and these areas map back to magnetic field lines near the antenna. The change in the power deposition at the target during ICH is compared with Thomson Scattering and RFEA measurements near the target. ORNL is managed by UT-Battelle, LLC, for the U.S. DOE under contract DE-AC-05-00OR22725.

  7. Radiation Thermometry—Sources of Uncertainty During Contactless Temperature Measurement

    Science.gov (United States)

    Reichel, Denise; Schumann, T.; Skorupa, W.; Lerch, W.; Gelpey, J.

    Short Time Annealing on a microsecond to nanosecond scale presents new challenges to temperature measurement. Pyrometers are widely used owing to their commercial availability, short response time, easy handling and contactless operation. However, they hold a source for considerable measurement errors. False readings are easily gained producing large errors during temperature measurement.

  8. Dynamics of Ion Beam Charge Neutralization by Ferroelectric Plasma Sources

    Science.gov (United States)

    Stepanov, Anton D.; Gilson, Erik P.; Grisham, Larry R.; Kaganovich, Igor D.; Davidson, Ronald C.; Ji, Qing; Persaud, Arun; Seidl, Peter A.; Schenkel, Thomas

    2016-10-01

    Ferroelectric Plasma Sources (FEPSs) can generate plasma that provides effective space-charge neutralization of intense high-perveance ion beams. Here we present experimental results on charge neutralization of a high-perveance 38 keV Ar+ beam by a FEPS plasma. By comparing the measured beam radius with the envelope model for space-charge expansion, it is shown that a charge neutralization fraction of 98% is attainable. The transverse electrostatic potential of the ion beam is reduced from 15 V before neutralization to 0.3 V, implying that the energy of the neutralizing electrons is below 0.3 eV. Near-complete charge neutralization is established 5 μs after the driving pulse is applied to the FEPS, and can last for 35 μs. It is argued that the duration of neutralization is much longer than a reasonable lifetime of the plasma produced in the sub- μs surface discharge. Measurements of current flow in the driving circuit of the FEPS suggest that plasma can be generated for tens of μs after the high voltage pulse is applied. This is confirmed by fast photography of the plasma in the 1-meter long FEPS on NDCX-II, where effective charge neutralization of the beam was achieved with the optimized FEPS timing. This work was supported by the Office of Science of the US Department of Energy under contracts DE-AC0209CH11466 (PPPL) and DE-AC0205CH11231 (LBNL).

  9. Progress with a gas-accepting ion source for Accelerator Mass Spectrometry

    Science.gov (United States)

    Roberts, M. L.; von Reden, K. F.; McIntyre, C. P.; Burton, J. R.

    2011-12-01

    The National Ocean Sciences AMS (NOSAMS) facility at Woods Hole Oceanographic Institution has developed a novel, gas-accepting microwave-plasma ion-source. The source is a key component of a compact Accelerator Mass Spectrometry (AMS) system built for the analysis of 14C in a continuously flowing gas stream. The gas source produces carbon currents from a stream of CO 2 with currents typical of a traditional graphite source. Details of the gas source, including ion current achieved, optimal flow rate, efficiency, and memory are presented. Additionally, data obtained from coupling a gas chromatograph to the source shown. Details about ion optics are presented separately [1].

  10. Temperature dependent dielectric properties and ion transportation in solid polymer electrolyte for lithium ion batteries

    Energy Technology Data Exchange (ETDEWEB)

    Sengwa, R. J., E-mail: rjsengwa@rediffmail.com; Dhatarwal, Priyanka, E-mail: dhatarwalpriyanka@gmail.com; Choudhary, Shobhna, E-mail: shobhnachoudhary@rediffmail.com [Dielectric Research Laboratory, Department of Physics, Jai Narain Vyas University, Jodhpur – 342 005 (India)

    2016-05-06

    Solid polymer electrolyte (SPE) film consisted of poly(ethylene oxide) (PEO) and poly(methyl methacrylate) (PMMA) blend matrix with lithium tetrafluroborate (LiBF{sub 4}) as dopant ionic salt and poly(ethylene glycol) (PEG) as plasticizer has been prepared by solution casting method followed by melt pressing. Dielectric properties and ionic conductivity of the SPE film at different temperatures have been determined by dielectric relaxation spectroscopy. It has been observed that the dc ionic conductivity of the SPE film increases with increase of temperature and also the decrease of relaxation time. The temperature dependent relaxation time and ionic conductivity values of the electrolyte are governed by the Arrhenius relation. Correlation observed between dc conductivity and relaxation time confirms that ion transportation occurs with polymer chain segmental dynamics through hopping mechanism. The room temperature ionic conductivity is found to be 4 × 10{sup −6} S cm{sup −1} which suggests the suitability of the SPE film for rechargeable lithium batteries.

  11. Test bench to commission a third ion source beam line and a newly designed extraction system

    Energy Technology Data Exchange (ETDEWEB)

    Winkelmann, T.; Cee, R.; Haberer, T.; Naas, B.; Peters, A. [Heidelberger Ionenstrahl-Therapie Centrum (HIT), D-69120 Heidelberg (Germany)

    2012-02-15

    The HIT (Heidelberg Ion Beam Therapy Center) is the first hospital-based treatment facility in Europe where patients can be irradiated with protons and carbon ions. Since the commissioning starting in 2006 two 14.5 GHz electron cyclotron resonance ion sources are routinely used to produce a variety of ion beams from protons up to oxygen. In the future a helium beam for regular patient treatment is requested, therefore a third ion source (Supernanogan source from PANTECHNIK S.A.) will be integrated. This third ECR source with a newly designed extraction system and a spectrometer line is installed at a test bench at HIT to commission and validate this section. Measurements with different extraction system setups will be presented to show the improvement of beam quality for helium, proton, and carbon beams. An outlook to the possible integration scheme of the new ion source into the production facility will be discussed.

  12. Test bench to commission a third ion source beam line and a newly designed extraction system.

    Science.gov (United States)

    Winkelmann, T; Cee, R; Haberer, T; Naas, B; Peters, A

    2012-02-01

    The HIT (Heidelberg Ion Beam Therapy Center) is the first hospital-based treatment facility in Europe where patients can be irradiated with protons and carbon ions. Since the commissioning starting in 2006 two 14.5 GHz electron cyclotron resonance ion sources are routinely used to produce a variety of ion beams from protons up to oxygen. In the future a helium beam for regular patient treatment is requested, therefore a third ion source (Supernanogan source from PANTECHNIK S.A.) will be integrated. This third ECR source with a newly designed extraction system and a spectrometer line is installed at a test bench at HIT to commission and validate this section. Measurements with different extraction system setups will be presented to show the improvement of beam quality for helium, proton, and carbon beams. An outlook to the possible integration scheme of the new ion source into the production facility will be discussed.

  13. Permanent magnet electron beam ion source/trap systems with bakeable magnets for improved operation conditions.

    Science.gov (United States)

    Schmidt, M; Zschornack, G; Kentsch, U; Ritter, E

    2014-02-01

    The magnetic system of a Dresden electron beam ion source (EBIS) generating the necessary magnetic field with a new type of permanent magnet made of high energy density NdFeB-type material operable at temperatures above 100 °C has been investigated and tested. The employment of such kind of magnets provides simplified operation without the time-consuming installation and de-installation procedures of the magnets for the necessary baking of the ion source after commissioning and maintenance work. Furthermore, with the use of a new magnetization technique the geometrical filling factor of the magnetic Dresden EBIS design could be increased to a filling factor of 100% leading to an axial magnetic field strength of approximately 0.5 T exceeding the old design by 20%. Simulations using the finite element method software Field Precision and their results compared with measurements are presented as well. It could be shown that several baking cycles at temperatures higher than 100 °C did not change the magnetic properties of the setup.

  14. Study of ion beam transport from the SECRAL electron cyclotron resonance ion source at the Institute of Modern Physics.

    Science.gov (United States)

    Cao, Y; Lu, W; Zhang, W H; Sha, S; Yang, Y; Ma, B H; Wang, H; Zhu, Y H; Guo, J W; Fang, X; Lin, S H; Li, X X; Feng, Y C; Li, J Y; Zhao, H Y; Ma, H Y; Zhang, X Z; Guo, X H; Wu, Q; Sun, L T; Zhao, H W; Xie, D Z

    2012-02-01

    Ion beam transport from the Superconducting Electron Cyclotron Resonance ion source with Advanced design in Lanzhou (SECRAL) electron cyclotron resonance ion source was studied at the Institute of Modern Physics during 2010. Particle-in-cell simulations and experimental results have shown that both space charge and magnetic aberrations lead to a larger beam envelope and emittance growth. In the existing SECRAL extraction beam line, it has been shown that raising the solenoid lens magnetic field reduces aberrations in the subsequent dipole and results in lower emittance. Detailed beam emittance measurements are presented in this paper.

  15. Temperature dependence of ion irradiation induced amorphization of zirconolite

    Energy Technology Data Exchange (ETDEWEB)

    Smith, K. L.; Blackford, M. G.; Lumpkin, G. R.; Zaluzec, N. J.

    1999-12-22

    Zirconolite is one of the major host phases for actinides in various wasteforms for immobilizing high level radioactive waste (HLW). Over time, zirconolite's crystalline matrix is damaged by {alpha}-particles and energetic recoil nuclei recoil resulting from {alpha}-decay events. The cumulative damage caused by these particles results in amorphization. Data from natural zirconolites suggest that radiation damage anneals over geologic time and is dependant on the thermal history of the material. Proposed HLW containment strategies rely on both a suitable wasteform and geologic isolation. Depending on the waste loading, depth of burial, and the repository-specific geothermal gradient, burial could result in a wasteform being exposed to temperatures of between 100--450 C. Consequently, it is important to assess the effect of temperature on radiation damage in synthetic zirconolite. Zirconolite containing wasteforms are likely to be hot pressed at or below 1,473 K (1,200 C) and/or sintered at or below 1,623 K (1,350 C). Zirconolite fabricated at temperatures below 1,523 K (1,250 C) contains many stacking faults. As there have been various attempts to link radiation resistance to structure, the authors decided it was also pertinent to assess the role of stacking faults in radiation resistance. In this study, they simulate {alpha}-decay damage in two zirconolite samples by irradiating them with 1.5 MeV Kr{sup +} ions using the High Voltage Electron Microscope-Tandem User Facility (HTUF) at Argonne National Laboratory (ANL) and measure the critical dose for amorphization (D{sub c}) at several temperatures between 20 and 773 K. One of the samples has a high degree of crystallographic perfection, the other contains many stacking faults on the unit cell scale. Previous authors proposed a model for estimating the activation energy of self annealing in zirconolite and for predicting the critical dose for amorphization at any temperature. The authors discuss their results

  16. High current DC negative ion source for cyclotron.

    Science.gov (United States)

    Etoh, H; Onai, M; Aoki, Y; Mitsubori, H; Arakawa, Y; Sakuraba, J; Kato, T; Mitsumoto, T; Hiasa, T; Yajima, S; Shibata, T; Hatayama, A; Okumura, Y

    2016-02-01

    A filament driven multi-cusp negative ion source has been developed for proton cyclotrons in medical applications. In Cs-free operation, continuous H(-) beam of 10 mA and D(-) beam of 3.3 mA were obtained stably at an arc-discharge power of 3 kW and 2.4 kW, respectively. In Cs-seeded operation, H(-) beam current reached 22 mA at a lower arc power of 2.6 kW with less co-extracted electron current. The optimum gas flow rate, which gives the highest H(-) current, was 15 sccm in the Cs-free operation, while it decreased to 4 sccm in the Cs-seeded operation. The relationship between H(-) production and the design/operating parameters has been also investigated by a numerical study with KEIO-MARC code, which gives a reasonable explanation to the experimental results of the H(-) current dependence on the arc power.

  17. Development and testing of a pulsed helium ion source for probing materials and warm dense matter studies

    Energy Technology Data Exchange (ETDEWEB)

    Ji, Q., E-mail: qji@lbl.gov; Seidl, P. A.; Waldron, W. L.; Takakuwa, J. H.; Persaud, A.; Schenkel, T. [Lawrence Berkeley National Laboratory, Berkeley, California 94720 (United States); Friedman, A.; Grote, D. P.; Barnard, J. J. [Lawrence Berkeley National Laboratory, Berkeley, California 94720 (United States); Lawrence Livermore National Laboratory, Livermore, California 94550 (United States)

    2016-02-15

    The neutralized drift compression experiment was designed and commissioned as a pulsed, linear induction accelerator to drive thin targets to warm dense matter (WDM) states with peak temperatures of ∼1 eV using intense, short pulses (∼1 ns) of 1.2 MeV lithium ions. At that kinetic energy, heating a thin target foil near the Bragg peak energy using He{sup +} ions leads to more uniform energy deposition of the target material than Li{sup +} ions. Experiments show that a higher current density of helium ions can be delivered from a plasma source compared to Li{sup +} ions from a hot plate type ion source. He{sup +} beam pulses as high as 200 mA at the peak and 4 μs long were measured from a multi-aperture 7-cm-diameter emission area. Within ±5% variation, the uniform beam area is approximately 6 cm across. The accelerated and compressed pulsed ion beams can be used for materials studies and isochoric heating of target materials for high energy density physics experiments and WDM studies.

  18. Design of the plasma grid for a short pulse negative ion source experimental setup at HUST

    Science.gov (United States)

    Zuo, C.; Li, D.; Chen, D.; Zhao, P.; Xu, Q.; Liao, Z.

    2017-08-01

    An experimental setup of a radio frequency (RF) driven negative hydrogen ion source has been developed at Huazhong University of Science and Technology (HUST). The setup without cesium oven and an extraction system had been completed and the plasma was ignited in the driver successfully in 2014. An extraction system with small area (5540 mm2) for short pulse (˜ 4 s) was designed to extract the negative hydrogen ions. Generally, the plasma grid temperature is controlled to reach 150 °C by the cooling channels inside the grid. But another method that we could use the PG current to raise the temperature is being considered only for the short pulse condition. An experiment was introduced to prove the feasibility of this method. A magnetic field produced by current flowing through the plasma grid is required to reduce the electron temperature and suppress the co-extraction electrons. The filter field homogeneity has been studied in detail by finite element method. There have been significant improvements regarding the field homogeneity by means of the grid geometry optimization.

  19. TWAC facility and the use of the laser ion source for production of intense heavy ion beams

    CERN Document Server

    Sharkov, B Yu; Shumshurov, A V; Meshcheryakov, N D; Rudskoy, I; Homenko, S; Makarov, K; Rörich, V; Stepanov, A; Satov, Yu A; Haseroth, H; Kugler, H; Lisi, N; Scrivens, R

    1999-01-01

    Current activities on upgrading of the ITEP heavy ion accelerator complex in the framework of the ITEP-TWAC project are reported. The project being in progress since 1997 is aiming at production of intense (100 kJ/100 ns) heavy ion beams. The basic idea of the project is the application of the non-Liouvillian technique in an existing accelerator facility based on a heavy ion synchrotron for its adaptation to heavy ion fusion related experiments. Special attention is paid to the results on generation of highly charged medium mass and heavy ions in the laser produced plasma. Development of key elements of the laser ion source based on the use of a 100 J repetition rate CO/sub 2/-laser for filling of ITEP and CERN accelerator facilities in the single turn injection mode is presented. (4 refs).

  20. RF-driven ion source with a back-streaming electron dump

    Science.gov (United States)

    Kwan, Joe; Ji, Qing

    2014-05-20

    A novel ion source is described having an improved lifetime. The ion source, in one embodiment, is a proton source, including an external RF antenna mounted to an RF window. To prevent backstreaming electrons formed in the beam column from striking the RF window, a back streaming electron dump is provided, which in one embodiment is formed of a cylindrical tube, open at one end to the ion source chamber and capped at its other end by a metal plug. The plug, maintained at the same electrical potential as the source, captures these backstreaming electrons, and thus prevents localized heating of the window, which due to said heating, might otherwise cause window damage.

  1. ANALYSIS OF X-RAY SPECTRA EMITTED FROM THE VENUS ECR ION SOURCE

    Energy Technology Data Exchange (ETDEWEB)

    Benitez, J.; Leitner, D.

    2008-01-01

    The Versatile Electron Cyclotron resonance ion source for Nuclear Science (VENUS), located at Lawrence Berkeley National Lab’s 88-inch cyclotron, extracts ion beams from a plasma created by ionizing a gas with energetic electrons. Liquid-helium cooled superconducting coils produce magnetic fi elds that confi ne the plasma and high microwave frequencies heat the electrons enough to allow for successive ionizations of the neutral gas atoms. The combination of strong plasma confi nement and high microwave frequencies results in VENUS’ production of record breaking ion beam currents and high charge state distributions. While in operation, VENUS produces signifi cant quantities of bremsstrahlung, in the form of x-rays, primarily through two processes: 1) electron-ion collisions within the plasma, and 2) electrons are lost from the plasma, collide with the plasma chamber wall, and radiate bremsstrahlung due to their sudden deceleration. The bremsstrahlung deposited into the plasma chamber wall is absorbed by the cold mass used to maintain superconductivity in the magnets and poses an additional heat load on the cryostat. In order for VENUS to reach its maximum operating potential of 10 kW of 28 GHz microwave heating frequency, the heat load posed by the emitted bremsstrahlung must be understood. In addition, studying the bremsstrahlung under various conditions will help further our understanding of the dynamics within the plasma. A code has been written, using the Python programming language, to analyze the recorded bremsstrahlung spectra emitted from the extraction end of VENUS. The code outputs a spectral temperature, which is relatively indicative of the temperature of the hot electrons, and total integrated count number corresponding to each spectra. Bremsstrahlung spectra are analyzed and compared by varying two parameters: 1) the heating frequency, 18 GHz and 28 GHz, and 2) the ratio between the minimum magnetic fi eld and the resonant magnetic fi eld, .44 and

  2. Design of the extraction system and beamline of the superconducting ECR ion source VENUS

    Energy Technology Data Exchange (ETDEWEB)

    Leitner, Matthaeus A.; Wutte, Daniela C.; Lyneis, Claude M.

    2001-05-07

    A new, very high magnetic field superconducting ECR ion source, VENUS, is under construction at the LBNL 88-Inch Cyclotron [1,2]. The paper describes the VENUS extraction system and discusses the ion beam formation in the strong axial magnetic field (3 T) of the ECR ion source. Emittance values as expected from theory, which assumes a uniform plasma density across the plasma outlet hole, are compared with actual measurements from the AECR-U ion source. Results indicate that highly charged heavier ions are concentrated on the source axis. They are extracted from an ''effective'' plasma outlet hole, whose smaller radius must be included in ion optics simulations.

  3. Advanced Electron Beam Ion Sources (EBIS) for 2-nd generation carbon radiotherapy facilities

    CERN Document Server

    Shornikov, A.

    2016-01-01

    In this work we analyze how advanced Electron Beam Ion Sources (EBIS) can facilitate the progress of carbon therapy facilities. We will demonstrate that advanced ion sources enable operation of 2-nd generation ion beam therapy (IBT) accelerators. These new accelerator concepts with designs dedicated to IBT provide beams better suited for therapy and, are more cost efficient than contemporary IBT facilities. We will give a sort overview of the existing new IBT concepts and focus on those where ion source technology is the limiting factor. We will analyse whether this limitation can be overcome in the near future thanks to ongoing EBIS development.

  4. Target-ion-source system for RNB facility at KEK Tanashi

    CERN Document Server

    Jeong, S C; Kawakami, H; Miyatake, H; Ishida, Y; Tojyo, E; Oyaizu, M; Mizutani, S; Yoshikawa, N; Tanaka, M H; Kawashima, H; Fuchi, Y; Wada, M; Katayama, I; Nomura, T

    2002-01-01

    For the radioactive nuclear beam facility at KEK Tanashi based on an isotope separator on-line (ISOL), two different types of ion sources are currently employed: a single stage 6.4 GHz ECR and a surface ionization-type ion sources. Several proton-rich radioactive nuclear beams were developed for astrophysical interests. LiF powder target in a water-cooled Cu container is used for the production of Ne isotopes and CaF sub 2 mixed with fine graphite powder for Na isotopes. The ion beams are bunched at the exit of the ion source in order to reduce the beam loss in post acceleration.

  5. Single-ion polymer electrolyte membranes enable lithium-ion batteries with a broad operating temperature range.

    Science.gov (United States)

    Cai, Weiwei; Zhang, Yunfeng; Li, Jing; Sun, Yubao; Cheng, Hansong

    2014-04-01

    Conductive processes involving lithium ions are analyzed in detail from a mechanistic perspective, and demonstrate that single ion polymeric electrolyte (SIPE) membranes can be used in lithium-ion batteries with a wide operating temperature range (25-80 °C) through systematic optimization of electrodes and electrode/electrolyte interfaces, in sharp contrast to other batteries equipped with SIPE membranes that display appreciable operability only at elevated temperatures (>60 °C). The performance is comparable to that of batteries using liquid electrolyte of inorganic salt, and the batteries exhibit excellent cycle life and rate performance. This significant widening of battery operation temperatures coupled with the inherent flexibility and robustness of the SIPE membranes makes it possible to develop thin and flexible Li-ion batteries for a broad range of applications. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Arbitrary amplitude ion-acoustic solitary waves in a two-temperature nonextensive electron plasma

    Science.gov (United States)

    Hatami, M. M.; Tribeche, M.

    2018-02-01

    Effects of presence of ions on the existence and structure of arbitrary amplitude ion-acoustic solitary waves in a plasma consisting of thermal ions and two-temperature nonextensive electrons are investigated. It is shown that solitons of both polarity (compressive and rarefactive) can exist in such a plasma, depending on the range of the plasma parameters. Also, it is seen that the maximum amplitude and the width of both soliton types depend sensitively on the temperature and concentration of ions. To better understand the role of positive ions, the presented model is reduced to a Maxwellian plasma and the results are compared to their Maxwellian counterparts.

  7. Mapping of low temperature heat sources in Denmark

    DEFF Research Database (Denmark)

    Bühler, Fabian; Holm, Fridolin Müller; Huang, Baijia

    2015-01-01

    heat. The total accessible waste heat potential is found to be approximately 266 PJ per year with 58 % of it below 100 °C. In the natural heat category, temperatures below 20 °C originate from ambient air, sea water and shallow geothermal energy, and temperatures up to 100 °C are found for solar...... and deep geothermal energy. The theoretical solar thermal potential alone would be above 500 PJ per year. For the development of advanced thermodynamic cycles for the integration of heat sources in the Danish energy system, several areas of interest are determined. In the maritime transport sector a high......Low temperature heat sources are available in many applications, ranging from waste heat from industrial processes and buildings to geothermal and solar heat sources. Technical advancements, such as heat pumps with novel cycle design and multi-component working fluids, make the utilisation of many...

  8. Boron ion beam production with the supernanogan ECR ion source for the CERN BIO-LEIR facility

    CERN Document Server

    Stafford-Haworth, J; Scrivens, R; Toivanen, V; Röhrich, J

    2014-01-01

    To deliver B3+ ions for medical research the compounds decaborane and m-carborane were tested using the metal ions from volatile compounds (MIVOC) method with the Supernanogan 14.5 GHz ECR ion source. Using decaborane the source delivered less than 10 A intensity of B3+ and after operation large deposits of material were found inside the source. Using m-carborane 50 A of B3+ were delivered without support gas. For m-carborane, helium and oxygen support gasses were also tested, and the effects of different source tuning parameters are discussed. The average consumption of m-carborane was 0:1 mg/Ah over all operation.

  9. Modification of anti-bacterial surface properties of textile polymers by vacuum arc ion source implantation

    Energy Technology Data Exchange (ETDEWEB)

    Nikolaev, A.G., E-mail: nik@opee.hcei.tsc.ru [High Current Electronics Institute, Siberian Branch of the Russian Academy of Sciences, Tomsk 634055 (Russian Federation); Yushkov, G.Yu.; Oks, E.M. [High Current Electronics Institute, Siberian Branch of the Russian Academy of Sciences, Tomsk 634055 (Russian Federation); Oztarhan, A. [Izmir University, Izmir 35140 (Turkey); Akpek, A.; Hames-Kocabas, E.; Urkac, E.S. [Bioengineering Department, Ege University, Bornova 35100, Izmir (Turkey); Brown, I.G. [Lawrence Berkeley National Laboratory, Berkeley, CA 94708 (United States)

    2014-08-15

    Highlights: • Ion implantation. • Anti-bacterial properties. • Textile polymer. • Vacuum arc ion source. - Abstract: Ion implantation provides an important technology for the modification of material surface properties. The vacuum arc ion source is a unique instrument for the generation of intense beams of metal ions as well as gaseous ions, including mixed metal–gas beams with controllable metal:gas ion ratio. Here we describe our exploratory work on the application of vacuum arc ion source-generated ion beams for ion implantation into polymer textile materials for modification of their biological cell compatibility surface properties. We have investigated two specific aspects of cell compatibility: (i) enhancement of the antibacterial characteristics (we chose to use Staphylococcus aureus bacteria) of ion implanted polymer textile fabric, and (ii) the “inverse” concern of enhancement of neural cell growth rate (we chose Rat B-35 neuroblastoma cells) on ion implanted polymer textile. The results of both investigations were positive, with implantation-generated antibacterial efficiency factor up to about 90%, fully comparable to alternative conventional (non-implantation) approaches and with some potentially important advantages over the conventional approach; and with enhancement of neural cell growth rate of up to a factor of 3.5 when grown on suitably implanted polymer textile material.

  10. Silicon defects characterization for low temperature ion implantation and RTA process

    Energy Technology Data Exchange (ETDEWEB)

    Martirani Paolillo, Diego; Margutti, Giovanni; De Biase, Marco [LFoundry s.r.l. Avezzano (Italy); Barozzi, Mario; Giubertoni, Damiano [Fondazione Bruno Kessler, Trento (Italy); Spaggiari, Claudio [Axcelis Technologies Srl, Agrate Brianza (Italy)

    2015-12-15

    In the last years a lot of effort has been directed in order to reduce silicon defects eventually formed during the ion implantation/anneal sequence used in the fabrication of CMOS devices. In this work we explored the effect of ion implant dose rate and temperature on the formation of silicon defects for high fluence {sup 49}BF{sub 2} implantations. The considered processes (implantation and annealing) conditions are those typically used to form the source/drain regions of p-channel transistors in the submicron technology node and will be detailed in the document. Characterization of implant damage and extended silicon defects left after anneal has been performed by TEM. Dopant distribution and dopant activation has been investigated by SIMS and SRP analysis. We have verified that implant dose rate and temperature modulate the thickness of the amorphous silicon observed after implant, as well as the concentrations of silicon defects left after anneal. Effect of high dose rate low temperature implantation on product device was also evaluated, showing a reduction of leakage current on p-channel transistors. Experimental set up, results and possible explanation will be reported and discussed in the paper.

  11. Comparison of Blackbody Sources for Low-Temperature IR Calibration

    Science.gov (United States)

    Ljungblad, S.; Holmsten, M.; Josefson, L. E.; Klason, P.

    2015-12-01

    Radiation thermometers are traditionally mostly used in high-temperature applications. They are, however, becoming more common in different applications at room temperature or below, in applications such as monitoring frozen food and evaluating heat leakage in buildings. To measure temperature accurately with a pyrometer, calibration is essential. A problem with traditional, commercially available, blackbody sources is that ice is often formed on the surface when measuring temperatures below 0°C. This is due to the humidity of the surrounding air and, as ice does not have the same emissivity as the blackbody source, it biases the measurements. An alternative to a traditional blackbody source has been tested by SP Technical Research Institute of Sweden. The objective is to find a cost-efficient method of calibrating pyrometers by comparison at the level of accuracy required for the intended use. A disc-shaped blackbody with a surface pyramid pattern is placed in a climatic chamber with an opening for field of view of the pyrometer. The temperature of the climatic chamber is measured with two platinum resistance thermometers in the air in the vicinity of the disc. As a rule, frost will form only if the deposition surface is colder than the surrounding air, and, as this is not the case when the air of the climatic chamber is cooled, there should be no frost or ice formed on the blackbody surface. To test the disc-shaped blackbody source, a blackbody cavity immersed in a conventional stirred liquid bath was used as a reference blackbody source. Two different pyrometers were calibrated by comparison using the two different blackbody sources, and the results were compared. The results of the measurements show that the disc works as intended and is suitable as a blackbody radiation source.

  12. Temperature dynamics and velocity scaling laws for interchange driven, warm ion plasma filaments

    DEFF Research Database (Denmark)

    Olsen, Jeppe Miki Busk; Madsen, Jens; Nielsen, Anders Henry

    2016-01-01

    The influence of electron and ion temperature dynamics on the radial convection of isolated structures in magnetically confined plasmas is investigated by means of numerical simulations. It is demonstrated that the maximum radial velocity of these plasma blobs roughly follows the inertial velocity...... scaling, which is proportional to the ion acoustic speed times the square root of the filament particle density times the sum of the electron and ion temperature perturbations. Only for small blobs the cross field convection does not follow this scaling. The influence of finite Larmor radius effects...... on the cross-field blob convection is shown not to depend strongly on the dynamical ion temperature field. The blob dynamics of constant finite and dynamical ion temperature blobs is similar. When the blob size is on the order of 10 times the ion Larmor radius the blobs stay coherent and decelerate slowly...

  13. Dependence of the depth distribution of implanted silver ions on the temperature of irradiated glass

    CERN Document Server

    Stepanov, A L

    2001-01-01

    The peculiarities of the glass ion implantation by the silver ions in dependence on the substrate temperature within the interval of 20-100 deg C are studied. Modeling the profiles of the implanted ions distribution in depth with an account of the thermostimulated increase in the admixture diffusion mobility is carried out. It is shown, that increase in the substrate temperature leads to the diffusion wash-out of the introduced admixture ions distribution. The analysis of the modeling results indicates the necessity of strict control of the substrate temperature by the dielectrics implantation for obtaining the conditions for the metal nanoparticles synthesis

  14. Measuring main-ion temperatures in ASDEX upgrade using scattering of ECRH radiation

    DEFF Research Database (Denmark)

    Pedersen, Morten Stejner; Nielsen, Stefan Kragh; Jacobsen, Asger Schou

    2016-01-01

    We demonstrate that collective Thomson scattering of millimeter wave electron cyclotron resonance heating radiation can be used for measurements of the main-ion temperature in the ASDEX Upgrade tokamak.......We demonstrate that collective Thomson scattering of millimeter wave electron cyclotron resonance heating radiation can be used for measurements of the main-ion temperature in the ASDEX Upgrade tokamak....

  15. Review on heavy ion radiotherapy facilities and related ion sources (invited)

    NARCIS (Netherlands)

    Kitagawa, A.; Fujita, T.; Muramatsu, M.; Biri, S.; Drentje, A. G.

    Heavy ion radiotherapy awakens worldwide interest recently. The clinical results obtained by the Heavy Ion Medical Accelerator in Chiba at the National Institute of Radiological Sciences in Japan have clearly demonstrated the advantages of carbon ion radiotherapy. Presently, there are four

  16. Commissioning of the superconducting ECR ion source VENUS at 18 GHz

    Energy Technology Data Exchange (ETDEWEB)

    Leitner, Daniela; Abbott, Steven R.; Dwinell, Roger D.; Leitner, Matthaeus; Taylor, Clyde E.; Lyneis, Claude M.

    2004-06-01

    During the last year, the VENUS ECR ion source was commissioned at 18 GHz and preparations for 28 GHz operation are now underway. During the commissioning phase with 18 GHz, tests with various gases and metals have been performed with up to 2000 W RF power. The ion source performance is very promising [1,2]. VENUS (Versatile ECR ion source for Nuclear Science) is a next generation superconducting ECR ion source, designed to produce high current, high charge state ions for the 88-Inch Cyclotron at the Lawrence Berkeley National Laboratory. VENUS also serves as the prototype ion source for the RIA (Rare Isotope Accelerator) front end. The goal of the VENUS ECR ion source project as the RIA R&D injector is the production of 240e{micro}A of U{sup 30+}, a high current medium charge state beam. On the other hand, as an injector ion source for the 88-Inch Cyclotron the design objective is the production of 5e{micro}A of U{sup 48+}, a low current, very high charge state beam. To meet these ambitious goals, VENUS has been designed for optimum operation at 28 GHz. This frequency choice has several design consequences. To achieve the required magnetic confinement, superconducting magnets have to be used. The size of the superconducting magnet structure implies a relatively large plasma volume. Consequently, high power microwave coupling becomes necessary to achieve sufficient plasma heating power densities. The 28 GHz power supply has been delivered in April 2004.

  17. Development of intense high-energy noble gas ion beams from in-terminal ion injector of tandem accelerator using an ECR ion source

    Energy Technology Data Exchange (ETDEWEB)

    Matsuda, M., E-mail: matsuda.makoto@jaea.go.jp [Japan Atomic Energy Agency (JAEA), Tokai Research and Development Center, 2-4 Shirakata-shirane, Tokai, Naka, Ibaraki 319-1195 (Japan); Nakanoya, T.; Hanashima, S.; Takeuchi, S. [Japan Atomic Energy Agency (JAEA), Tokai Research and Development Center, 2-4 Shirakata-shirane, Tokai, Naka, Ibaraki 319-1195 (Japan)

    2011-10-21

    An ECRIS-based heavy ion injector was constructed in the high-voltage terminal of JAEA-Tokai Tandem Accelerator to develop new beam species of highly charged noble gas ions. This work was associated with a lot of development to operate the ion source on the 20UR Pelletron high voltage terminal in high pressure SF{sub 6} gas environment. Highly charged ions of N, O, Ne, Ar, Kr and Xe have been accelerated satisfactorily. Operating data integrated during many years long beam delivery service are summarized.

  18. Imaging many-body Coulomb interactions and ultrafast photoionization and diffraction with cold atom electron and ion sources

    Science.gov (United States)

    Scholten, Robert; Speirs, Rory; Murphy, Dene; Torrance, Joshua; Thompson, Daniel; Sparkes, Benjamin; McCulloch, Andrew

    2017-04-01

    The CAEIS cold-atom electron/ion source, based on photoionisation of laser cooled atoms, provides a powerful tool for investigating fundamental physical processes. The very low temperature of the ions has allowed us to image intra-beam Coulomb effects with unprecedented detail. With ultrafast laser excitation and streak detection we can probe competing ionization processes, particularly via Rydberg states, including sequential excitation, multiphoton excitation, resonance-enhanced multiphoton excitation and two-color multiphoton excitation. Knowledge from these studies has enabled ultrafast single-shot diffractive electron imaging with atomic resolution using a CAEIS.

  19. Ion temperature anisotropy in high power helium neutral beam fuelling experiments in JET

    Energy Technology Data Exchange (ETDEWEB)

    Maas, A.C.; Core, W.G.F.; Gerstel, U.C.; Von Hellermann, M.G.; Koenig, R.W.T.; Marcus, F.B. [Commission of the European Communities, Abingdon (United Kingdom). JET Joint Undertaking

    1994-07-01

    During helium beam fuelling experiments in JET, distinctive anisotropic features have been observed in the velocity distribution function describing both fast and thermal alpha particle populations. During the initial fuelling phase the central helium ion temperature observed perpendicular to the magnetic field is higher than the central electron temperature, while the central helium ion temperature observed parallel to the magnetic field is lower than or equal to the central electron temperature. In order to verify temperature measurements of both perpendicular and parallel lines of sight, other independent methods of deducing the ion temperature are investigated: deuterium ion temperature, deuterium density, comparison with neutron rates and profiles (influence of a possible metastable population of helium). 6 refs., 7 figs.

  20. The third generation superconducting 28 GHz electron cyclotron resonance ion source VENUS (invited)

    Energy Technology Data Exchange (ETDEWEB)

    Lyneis, C.; Leitner, D.; Leitner, M.; Taylor, C.; Abbott, S. [Lawrence Berkeley National Laboratory, One Cyclotron Road, Berkeley, California 94720 (United States)

    2010-02-15

    VENUS is a third generation electron cyclotron resonance (ECR) ion source, which incorporates a high field superconducting NbTi magnet structure, a 28 GHz gryotron microwave source and a state of the art closed cycle cryosystem. During the decade from initial concept to regular operation, it has demonstrated both the feasibility and the performance levels of this new generation of ECR ion sources and required innovation on magnet construction, plasma chamber design, and beam transport. In this paper, the development, performance, and major innovations are described as well as a look to the potential to construct a fourth generation ECR ion source.

  1. A hybrid electron cyclotron resonance metal ion source with integrated sputter magnetron for the production of an intense Al{sup +} ion beam

    Energy Technology Data Exchange (ETDEWEB)

    Weichsel, T., E-mail: tim.weichsel@fep.fraunhofer.de; Hartung, U.; Kopte, T. [Fraunhofer Institute for Organic Electronics, Electron Beam and Plasma Technology FEP, 01277 Dresden (Germany); Zschornack, G. [Institute of Solid State Physics, Dresden University of Technology, 01062 Dresden, Germany and Helmholtz-Zentrum Dresden-Rossendorf e.V., Institute of Ion Beam Physics and Materials Research, Dresden (Germany); Kreller, M.; Philipp, A. [DREEBIT GmbH, 01900 Grossroehrsdorf (Germany)

    2015-09-15

    A metal ion source prototype has been developed: a combination of magnetron sputter technology with 2.45 GHz electron cyclotron resonance (ECR) ion source technology—a so called magnetron ECR ion source (MECRIS). An integrated ring-shaped sputter magnetron with an Al target is acting as a powerful metal atom supply in order to produce an intense current of singly charged metal ions. Preliminary experiments show that an Al{sup +} ion current with a density of 167 μA/cm{sup 2} is extracted from the source at an acceleration voltage of 27 kV. Spatially resolved double Langmuir probe measurements and optical emission spectroscopy were used to study the plasma states of the ion source: sputter magnetron, ECR, and MECRIS plasma. Electron density and temperature as well as Al atom density were determined as a function of microwave and sputter magnetron power. The effect of ECR heating is strongly pronounced in the center of the source. There the electron density is increased by one order of magnitude from 6 × 10{sup 9} cm{sup −3} to 6 × 10{sup 10} cm{sup −3} and the electron temperature is enhanced from about 5 eV to 12 eV, when the ECR plasma is ignited to the magnetron plasma. Operating the magnetron at constant power, it was observed that its discharge current is raised from 1.8 A to 4.8 A, when the ECR discharge was superimposed with a microwave power of 2 kW. At the same time, the discharge voltage decreased from about 560 V to 210 V, clearly indicating a higher plasma density of the MECRIS mode. The optical emission spectrum of the MECRIS plasma is dominated by lines of excited Al atoms and shows a significant contribution of lines arising from singly ionized Al. Plasma emission photography with a CCD camera was used to prove probe measurements and to identify separated plasma emission zones originating from the ECR and magnetron discharge.

  2. Measurements of ion temperature and flow of pulsed plasmas produced by a magnetized coaxial plasma gun device using an ion Doppler spectrometer

    Science.gov (United States)

    Kitagawa, Y.; Sakuma, I.; Iwamoto, D.; Kikuchi, Y.; Fukumoto, N.; Nagata, M.

    2012-10-01

    It is important to know surface damage characteristics of plasma-facing component materials during transient heat and particle loads such as type I ELMs. A magnetized coaxial plasma gun (MCPG) device has been used as transient heat and particle source in ELM simulation experiments. Characteristics of pulsed plasmas produced by the MCPG device play an important role for the plasma material interaction. In this study, ion temperature and flow velocity of pulsed He plasmas were measured by an ion Doppler spectrometer (IDS). The IDS system consists of a light collection system including optical fibers, 1m-spectrometer and a 16 channel photomultiplier tube (PMT) detector. The IDS system measures the width and Doppler shift of HeII (468.58 nm) emission line with the time resolution of 1 μs. The Doppler broadened and shifted spectra were measured with 45 and 135 degree angles with respect to the plasmoid traveling direction. The observed emission line profile was represented by sum of two Gaussian components to determine the temperature and flow velocity. The minor component at around the wavelength of zero-velocity was produced by the stationary plasma. As the results, the ion velocity and temperature were 68 km/s and 19 eV, respectively. Thus, the He ion flow energy is 97 eV. The observed flow velocity agrees with that measured by a time of flight technique.

  3. A carbon-cluster laser ion source for TRIGA-TRAP

    Science.gov (United States)

    Smorra, C.; Blaum, K.; Eberhardt, K.; Eibach, M.; Ketelaer, J.; Ketter, J.; Knuth, K.; Nagy, Sz

    2009-08-01

    A new laser ablation ion source was developed and tested for the Penning trap mass spectrometer TRIGA-TRAP in order to provide carbon-cluster ions for absolute mass calibration. Ions of different cluster sizes up to C+24 were successfully produced, covering the mass range up to the heavy actinide elements. The ions were captured in a Penning trap, and their time-of-flight cyclotron resonances recorded in order to determine their cyclotron frequency. Furthermore, the same ion source was used to produce GdO+ ions from a gadolinium target in sufficient amount for mass spectrometry purposes. The design of the source and its characteristics are presented. This paper comprises partly the PhD theses of J Ketelaer and C Smorra.

  4. Progress of superconducting electron cyclotron resonance ion sources at Institute of Modern Physics (IMP).

    Science.gov (United States)

    Sun, L; Lu, W; Feng, Y C; Zhang, W H; Zhang, X Z; Cao, Y; Zhao, Y Y; Wu, W; Yang, T J; Zhao, B; Zhao, H W; Ma, L Z; Xia, J W; Xie, D

    2014-02-01

    Superconducting ECR ion sources can produce intense highly charged ion beams for the application in heavy ion accelerators. Superconducting Electron Resonance ion source with Advanced Design (SECRAL) is one of the few fully superconducting ECR ion sources that has been successfully built and put into routine operation for years. With enormous efforts and R&D work, promising results have been achieved with the ion source. Heated by the microwave power from a 7 kW/24 GHz gyrotron microwave generator, very intense highly charged gaseous ion beams have been produced, such as 455 eμA Xe(27+), 236 eμA Xe(30+), and 64 eμA Xe(35+). Since heavy metallic ion beams are being more and more attractive and important for many accelerator projects globally, intensive studies have been made to produce highly charged heavy metal ion beams, such as those from bismuth and uranium. Recently, 420 eμA Bi(30+) and 202 eμA U(33+) have been produced with SECRAL source. This paper will present the latest results with SECRAL, and the operation status will be discussed as well. An introduction of recently started SECRAL II project will also be given in the presentation.

  5. Spatial distribution of charged particles along the ion-optical axis in electron cyclotron resonance ion sources. Experimental results

    Energy Technology Data Exchange (ETDEWEB)

    Panitzsch, Lauri

    2013-02-08

    The experimental determination of the spatial distribution of charged particles along the ion-optical axis in electron cyclotron resonance ion sources (ECRIS) defines the focus of this thesis. The spatial distributions of different ion species were obtained in the object plane of the bending magnet ({approx}45 cm downstream from the plasma electrode) and in the plane of the plasma electrode itself, both in high spatial resolution. The results show that each of the different ion species forms a bloated, triangular structure in the aperture of the plasma electrode. The geometry and the orientation of these structures are defined by the superposition of the radial and axial magnetic fields. The radial extent of each structure is defined by the charge of the ion. Higher charge states occupy smaller, more concentrated structures. The total current density increases towards the center of the plasma electrode. The circular and star-like structures that can be observed in the beam profiles of strongly focused, extracted ion beams are each dominated by ions of a single charge state. In addition, the spatially resolved current density distribution of charged particles in the plasma chamber that impinge on the plasma electrode was determined, differentiating between ions and electrons. The experimental results of this work show that the electrons of the plasma are strongly connected to the magnetic field lines in the source and thus spatially well confined in a triangular-like structure. The intensity of the electrons increases towards the center of the plasma electrode and the plasma chamber, as well. These electrons are surrounded by a spatially far less confined and less intense ion population. All the findings mentioned above were already predicted in parts by simulations of different groups. However, the results presented within this thesis represent the first (and by now only) direct experimental verification of those predictions and are qualitatively transferable to

  6. Time evolution of endpoint energy of Bremsstrahlung spectra and ion production from an electron cyclotron resonance ion source

    Energy Technology Data Exchange (ETDEWEB)

    Tarvainen, Ollie [Los Alamos National Laboratory; Ropponen, Tommi [JYFL; Jones, Peter [JYFL; Kalvas, Taneli [JYFL

    2008-01-01

    Electron cyclotron resonance ion sources (ECRIS) are used to produce high charge state heavy ion beams for the use of nuclear and materials science, for instance. The most powerful ECR ion sources today are superconducting. One of the problems with superconducting ECR ion sources is the use of high radio frequency (RF) power which results in bremsstrahlung radiation adding an extra heat load to the cryostat. In order to understand the electron heating process and timescales in the ECR plasma, time evolution measurement of ECR bremsstrahlung was carried out. In the measurements JYFL 14 GHz ECRIS was operated in a pulsed mode and bremsstrahlung data from several hundred RF pulses was recorded. Time evolution of ion production was also studied and compared to one of the electron heating theories. To analyze the measurement data at C++ program was developed. Endpoint energies of the bremsstrahlung spectra as a function of axial magnetic field strength, pressure and RF power are presented and ion production timescales obtained from the measurements are compared to bremsstrahlung emission timescales and one of the stochastic heating theories.

  7. Ion source development for the JAERI on-line isotope separator

    CERN Document Server

    Ichikawa, S; Matsuda, M; Tsukada, K; Asai, M; Nagame, Y; Jeong, S C; Katayama, I

    2003-01-01

    In accordance with the JAERI-KEK joint radioactive nuclear beam (RNB) project, we have installed a forced electron beam induced arc discharge (FEBIAD) type integrated-target-ion source in the JAERI-ISOL to produce heavy neutron-rich RNBs with particle-induced fission of sup 2 sup 3 sup 8 U. In the present ion source, a 2.6-g sup 2 sup 3 sup 8 UC sub 2 target is directly attached to a plasma chamber. RNBs of sup 8 Li, sup 1 sup 8 F and sup 2 sup 0 F are also planned to be used for the study of thermal diffusion in materials in the joint project. Release profiles of sup 7 Li have been studied using a cavity type thermal ion source. For mass-separation of F atoms, the molecular ion formations have been examined using the FEBIAD ion source.

  8. Power generation from low-temperature heat source

    Energy Technology Data Exchange (ETDEWEB)

    Lakew, Amlaku Abie

    2012-07-01

    The potential of low-temperature heat sources for power production has been discussed for decades. The diversity and availability of low-temperature heat sources makes it interesting for power production. The thermodynamic power cycle is one of the promising technologies to produce electricity from low-temperature heat sources. There are different working fluids to be used in a thermodynamic power cycle. Working fluid selection is essential for the performance of the power cycle. Over the last years, different working fluid screening criteria have been used. In broad speaking the screening criteria can be grouped as thermodynamic performance, component size requirement, economic performance, safety and environmental impact. Screening of working fluids at different heat source temperatures (80-200 Celsius degrees) using thermodynamic performance (power output and exergy efficiency) and component size (heat exchanger and turbine) is investigated. It is found that the 'best' working fluid depends on the criteria used and heat source temperature level. Transcritical power cycles using carbon dioxide as a working fluid is studied to produce power at 100 Celsius degrees. Carbon dioxide is an environmentally friendly refrigerant. The global warming potential of carbon dioxide is 1. Furthermore, because of its low critical temperature (31 Celsius degrees), carbon dioxide can operate in a transcritical power cycle for lower heat source temperatures. A transcritical configuration avoids the problem of pinching which otherwise would happened in subcritical power cycle. In the process, better temperature matching is achieved and more heat is extracted. Thermodynamic analysis of transcritical cycle is performed; it is found that there is an optimal operating pressure for highest net power output. The pump work is a sizable fraction of the work produced by the turbine. The effect of efficiency deterioration of the pump and the turbine is compared. When the

  9. Development open source microcontroller based temperature data logger

    Science.gov (United States)

    Abdullah, M. H.; Che Ghani, S. A.; Zaulkafilai, Z.; Tajuddin, S. N.

    2017-10-01

    This article discusses the development stages in designing, prototyping, testing and deploying a portable open source microcontroller based temperature data logger for use in rough industrial environment. The 5V powered prototype of data logger is equipped with open source Arduino microcontroller for integrating multiple thermocouple sensors with their module, secure digital (SD) card storage, liquid crystal display (LCD), real time clock and electronic enclosure made of acrylic. The program for the function of the datalogger is programmed so that 8 readings from the thermocouples can be acquired within 3 s interval and displayed on the LCD simultaneously. The recorded temperature readings at four different points on both hydrodistillation show similar profile pattern and highest yield of extracted oil was achieved on hydrodistillation 2 at 0.004%. From the obtained results, this study achieved the objective of developing an inexpensive, portable and robust eight channels temperature measuring module with capabilities to monitor and store real time data.

  10. Kinetic modeling of particle dynamics in H{sup −} negative ion sources (invited)

    Energy Technology Data Exchange (ETDEWEB)

    Hatayama, A., E-mail: akh@ppl.appi.keio.ac.jp; Shibata, T.; Nishioka, S.; Ohta, M.; Yasumoto, M.; Nishida, K.; Yamamoto, T. [Faculty of Science and Technology, Keio University, 3-14-1 Hiyoshi, Kohoku-ku, Yokohama, 223-8522 (Japan); Miyamoto, K. [Naruto University of Education, 748 Nakashima, Takashima, Naruto-cho, Naruto-shi, Tokushima 772-8502 (Japan); Fukano, A. [Monozukuri Department, Tokyo Metropolitan College of Industrial Technology, Shinagawa, Tokyo 140-0011 (Japan); Mizuno, T. [Department of Management Science, College of Engineering, Tamagawa University, Machida, Tokyo 194-8610 (Japan)

    2014-02-15

    Progress in the kinetic modeling of particle dynamics in H{sup −} negative ion source plasmas and their comparisons with experiments are reviewed, and discussed with some new results. Main focus is placed on the following two topics, which are important for the research and development of large negative ion sources and high power H{sup −} ion beams: (i) Effects of non-equilibrium features of EEDF (electron energy distribution function) on H{sup −} production, and (ii) extraction physics of H{sup −} ions and beam optics.

  11. Influence of discharge gap on the discharge stability in a short vacuum arc ion source

    Energy Technology Data Exchange (ETDEWEB)

    Chen, L. [Institute of Electronic Engineering, China Academy of Engineering Physics, Mianyang, Sichuan 621900 (China); Department of Engineering Physics, Tsinghua University, Beijing 100084 (China); Zhang, G. L.; Jin, D. Z.; Dai, J. Y. [Institute of Electronic Engineering, China Academy of Engineering Physics, Mianyang, Sichuan 621900 (China); Yang, L. [Institute of Nuclear Science and Technology, Louzhou University, Lanzhou, Gansu 730000 (China)

    2012-02-15

    The influence of the discharge gap between cathode and anode on the discharge stability in a short vacuum arc (SVA) ion source is presented in this paper. Planar cathode and cylindrical hollow anode made of titanium are investigated. There is a great need in present accelerator injection research for SVA source to produce the small deviation of the ion current beam. Current research shows that increasing the short discharge gap can reduce the level of ion current deviation and ion charge deviation from 29% and 31% to 15% and 17%, respectively. A microplasma plume generation mechanism in SVA and scanning electron microscopic results can be used to explain this interesting phenomenon.

  12. Integrating a Traveling Wave Tube into an AECR-U ion source

    Energy Technology Data Exchange (ETDEWEB)

    Covo, Michel Kireeff; Benitez, Janilee Y.; Ratti, Alessandro; Vujic, Jasmina L.

    2011-07-01

    An RF system of 500W - 10.75 to 12.75 GHz was designed and integrated into the Advanced Electron Cyclotron Resonance - Upgrade (AECR-U) ion source of the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory. The AECR-U produces ion beams for the Cyclotron giving large flexibility of ion species and charge states. The broadband frequency of a Traveling Wave Tube (TWT) allows modifying the volume that couples and heats the plasma. The TWT system design and integration with the AECR-U ion source and results from commissioning are presented.

  13. V.U.V. plasma spectroscopy diagnostic of electron cyclotron resonance multicharged ion sources; Diagnostic de plasmas crees dans des sources d'ions multicharges a resonance cyclotronique electronique par spectroscopie V.U.V

    Energy Technology Data Exchange (ETDEWEB)

    Berreby, R

    1997-12-15

    To characterize the multicharged ions within the plasma of an E.C.R. ion source, the V.U.V. spectroscopy is used as a non invasive diagnostic of excited matter. In E.C.R.I. S. (electron cyclotron resonance ion source) electrons are heated and magnetically confined within the mirror machine to overcome the successive ionization potentials of the desired elements. As the electrons bounce inside the magnetic configuration in their gyration movement, they interact with the microwaves injected into the source at the resonance frequency. To enhance the performances in high charge states and extracted currents delivered by E.C.R.I.S., the fundamental parameters of the plasma created in these machines must be known. The goal of spectroscopic diagnostics in the V.U.V. range installed on the sources is to determine electron density and temperature on one hand, and the ionic densities and confinement time on the other hand. We used microchannel plates as detector on a 3 meter grazing incidence spectrometer equipped with a 600 lines/mm holographic grating. The calibration of the whole grating with detector was performed by two different methods. These are the branching ratio and charge exchange methods. Identification of lines emitted by a plasma, which gather the whole charge states of ions is necessary to make an exhaustive study of the plasma state. And finally, the determination of plasma parameters like electron density and temperature and ion densities and confinement times that uses theoretical models were the aim of this work. (author)

  14. Ion temperature and hydrodynamic-energy measurements in a Z-pinch plasma at stagnation.

    Science.gov (United States)

    Kroupp, E; Osin, D; Starobinets, A; Fisher, V; Bernshtam, V; Weingarten, L; Maron, Y; Uschmann, I; Förster, E; Fisher, A; Cuneo, M E; Deeney, C; Giuliani, J L

    2011-09-02

    The time history of the local ion kinetic energy in a stagnating plasma was determined from Doppler-dominated line shapes. Using independent determination of the plasma properties for the same plasma region, the data allowed for inferring the time-dependent ion temperature, and for discriminating the temperature from the total ion kinetic energy. It is found that throughout most of the stagnation period the ion thermal energy constitutes a small fraction of the total ion kinetic energy; the latter is dominated by hydrodynamic motion. Both the ion hydrodynamic and thermal energies are observed to decrease to the electron thermal energy by the end of the stagnation period. It is confirmed that the total ion kinetic energy available at the stagnating plasma and the total radiation emitted are in balance, as obtained in our previous experiment. The dissipation time of the hydrodynamic energy thus appears to determine the duration (and power) of the K emission.

  15. Core-ion temperature measurement of the ADITYA tokamak using passive charge exchange neutral particle energy analyzer

    Energy Technology Data Exchange (ETDEWEB)

    Pandya, Santosh P.; Ajay, Kumar; Mishra, Priyanka; Dhingra, Rajani D.; Govindarajan, J. [Institute for Plasma Research, Bhat, Gandhinagar 382 428, Gujarat (India)

    2013-02-15

    Core-ion temperature measurements have been carried out by the energy analysis of passive charge exchange (CX) neutrals escaping out of the ADITYA tokamak plasma (minor radius, a= 25 cm and major radius, R= 75 cm) using a 45 Degree-Sign parallel plate electrostatic energy analyzer. The neutral particle analyzer (NPA) uses a gas cell configuration for re-ionizing the CX-neutrals and channel electron multipliers (CEMs) as detectors. Energy calibration of the NPA has been carried out using ion-source and {Delta}E/E of high-energy channel has been found to be {approx}10%. Low signal to noise ratio (SNR) due to VUV reflections on the CEMs was identified during the operation of the NPA with ADITYA plasma discharges. This problem was rectified by upgrading the system by incorporating the additional components and arrangements to suppress VUV radiations and improve its VUV rejection capabilities. The noise rejection capability of the NPA was experimentally confirmed using a standard UV-source and also during the plasma discharges to get an adequate SNR (>30) at the energy channels. Core-ion temperature T{sub i}(0) during flattop of the plasma current has been measured to be up to 150 eV during ohmically heated plasma discharges which is nearly 40% of the average core-electron temperature (typically T{sub e}(0) {approx} 400 eV). The present paper describes the principle of tokamak ion temperature measurement, NPA's design, development, and calibration along with the modifications carried out for minimizing the interference of plasma radiations in the CX-spectrum. Performance of the NPA during plasma discharges and experimental results on the measurement of ion-temperature have also been reported here.

  16. Ion beam extraction from a matrix ECR plasma source by discrete ion-focusing effect

    DEFF Research Database (Denmark)

    Stamate, Eugen; Draghici, Mihai

    2010-01-01

    with high current densities that can treat surfaces placed adjacent to the extraction region. This work introduces a new phenomenology for ion beam extraction using the discrete ion-focusing effect associated with three-dimensional plasma-sheath-lenses [1, 2]. Experiments are performed in a matrix......Torr and plasma densities around 1016 m-3. A rectangular plasma-sheath-lens is created by an electrode-insulator interface designed by finite element simulations. The discrete ion-focusing effect deflects the ions to and extraction aperture on the electrode. A linearly distributed positive ion beam is extracted......Positive or negative ion beams extracted from plasma are used in a large variety of surface functionalization techniques such as implantation, etching, surface activation, passivation or oxidation. Of particular importance is the surface treatment of materials sensitive to direct plasma exposure...

  17. Next generation ECR ion sources: First results of the superconducting 28 GHz ECRIS - VENUS

    Energy Technology Data Exchange (ETDEWEB)

    Leitner, D. [Lawrence Berkeley National Laboratory, 1 Cyclotron Road, MS 88R0192, Berkeley, CA 94720 (United States)]. E-mail: dleitner@lbl.gov; Lyneis, C.M. [Lawrence Berkeley National Laboratory, 1 Cyclotron Road, MS 88R0192, Berkeley, CA 94720 (United States); Abbott, S.R. [Lawrence Berkeley National Laboratory, 1 Cyclotron Road, MS 88R0192, Berkeley, CA 94720 (United States); Collins, D. [Lawrence Berkeley National Laboratory, 1 Cyclotron Road, MS 88R0192, Berkeley, CA 94720 (United States); Dwinell, R.D. [Lawrence Berkeley National Laboratory, 1 Cyclotron Road, MS 88R0192, Berkeley, CA 94720 (United States); Galloway, M.L. [Lawrence Berkeley National Laboratory, 1 Cyclotron Road, MS 88R0192, Berkeley, CA 94720 (United States); Leitner, M. [Lawrence Berkeley National Laboratory, 1 Cyclotron Road, MS 88R0192, Berkeley, CA 94720 (United States); Todd, D.S. [Lawrence Berkeley National Laboratory, 1 Cyclotron Road, MS 88R0192, Berkeley, CA 94720 (United States)

    2005-07-01

    VENUS (Versatile ECR ion source for NUclear Science) is a next generation superconducting ECR ion source, designed to produce high current, high charge state ions for the 88-Inch Cyclotron at the Lawrence Berkeley National Laboratory. VENUS also serves as the prototype ion source for the RIA (rare isotope accelerator) front end. The goal of the VENUS ECR ion source project as the RIA R and D injector is the production of 200 e{mu}A of U{sup 30+}, a high current medium charge state beam. On the other hand, as an injector ion source for the 88-Inch Cyclotron the design objective is the production of 5 e{mu}A of U{sup 48+}, a low current, very high charge state beam. To achieve those ambitious goals, the VENUS ECR ion source has been designed for optimum operation at 28 GHz. The nominal design fields of the axial magnets are 4 T at injection and 3 T at extraction; the nominal radial design field strength at the plasma chamber wall is 2 T, making VENUS currently the world's most powerful ECR plasma confinement structure. Recently, the six year project has made significant progress. In June 2002, the first plasma was ignited at 18 GHz. During 2003, the VENUS ECR ion source was commissioned at 18 GHz, while preparations for 28 GHz operation were being conducted. In May 2004 28 GHz microwave power has been coupled into the VENUS ECR ion source for the first time. Preliminary performance-tests with oxygen, xenon and bismuth at 18 GHz and 28 GHz have shown promising results. Intensities close to or exceeding the RIA requirements have been produced for those few test beams. The paper will briefly describe the design of the VENUS source and its beam analyzing system. Results at 18 GHz and 28 GHz including first emittance measurements will be described.

  18. An Empirical Temperature Variance Source Model in Heated Jets

    Science.gov (United States)

    Khavaran, Abbas; Bridges, James

    2012-01-01

    An acoustic analogy approach is implemented that models the sources of jet noise in heated jets. The equivalent sources of turbulent mixing noise are recognized as the differences between the fluctuating and Favre-averaged Reynolds stresses and enthalpy fluxes. While in a conventional acoustic analogy only Reynolds stress components are scrutinized for their noise generation properties, it is now accepted that a comprehensive source model should include the additional entropy source term. Following Goldstein s generalized acoustic analogy, the set of Euler equations are divided into two sets of equations that govern a non-radiating base flow plus its residual components. When the base flow is considered as a locally parallel mean flow, the residual equations may be rearranged to form an inhomogeneous third-order wave equation. A general solution is written subsequently using a Green s function method while all non-linear terms are treated as the equivalent sources of aerodynamic sound and are modeled accordingly. In a previous study, a specialized Reynolds-averaged Navier-Stokes (RANS) solver was implemented to compute the variance of thermal fluctuations that determine the enthalpy flux source strength. The main objective here is to present an empirical model capable of providing a reasonable estimate of the stagnation temperature variance in a jet. Such a model is parameterized as a function of the mean stagnation temperature gradient in the jet, and is evaluated using commonly available RANS solvers. The ensuing thermal source distribution is compared with measurements as well as computational result from a dedicated RANS solver that employs an enthalpy variance and dissipation rate model. Turbulent mixing noise predictions are presented for a wide range of jet temperature ratios from 1.0 to 3.20.

  19. A New Broadband Microwave Frequency Device for Powering ECR Ion Sources

    CERN Document Server

    Kawai, Yoko; Liu, Yuan

    2005-01-01

    The multiple discrete frequency technique has been used to improve the performance of conventional B-field configuration ECR ion sources. However, the practical application of this technique is very costly, requiring multiple independent single-frequency rf power supplies and complicated rf injection systems. Broadband sources of rf power offer a low-cost and more effective method for increasing the physical size of the ECR zone within these ion sources. An Additive White Gaussian Noise Generator (AWGNG) system for injecting broadband rf power into these ion sources has been developed in conjunction with a commercial firm. The noise generator, in combination with an external oscillator and a traveling wave tube amplifier, can be used to generate broadband rf power without modifying the injection system. The AWGNG and its use for enhancing the performance of conventional B-field configuration ECR ion sources will be described.

  20. Study of Low Work Function Materials for Hot Cavity Resonance Ionization Laser Ion Sources

    CERN Document Server

    Catherall, R; Fedosseev, V; Marsh, B; Mattolat, C; Menna, Mariano; Österdahl, F; Raeder, S; Schwellnus, F; Stora, T; Wendt, K; CERN. Geneva. AB Department

    2008-01-01

    The selectivity of a hot cavity resonance ionization laser ion source (RILIS) is most often limited by contributions from competing surface ionization on the hot walls of the ionization cavity. In this article we present investigations on the properties of designated high-temperature, low-work function materials regarding their performance and suitability as cavity material for RILIS. Tungsten test cavities, impregnated with a mixture of barium oxide and strontium oxide (BaOSrO on W), or alternatively gadolinium hexaboride (GdB6) were studied in comparison to a standard tungsten RILIS cavity as being routinely used for hot cavity laser ionization at ISOLDE. Measurement campaigns took place at the off-line mass separators at ISOLDE / CERN, Geneva and RISIKO / University of Mainz.

  1. Study of low work function materials for hot cavity resonance ionization laser ion sources

    CERN Document Server

    Schwellnus, F; Crepieux, B; Fedosseev, V N; Marsh, B A; Mattolat, Ch; Menna, M; Österdahl, F K; Raeder, S; Stora, T; Wendta, K

    2009-01-01

    The selectivity of a hot cavity resonance ionization laser ion source (RILIS) is most often limited by contributions from competing surface ionization of the hot walls of the ionization cavity. In this article we present investigations on the properties of designated high temperature, low work function materials regarding their performance and suitability as cavity material for RILIS. Tungsten test cavities, impregnated with a mixture of barium oxide and strontium oxide (BaOSrO on W), or alternatively gadolinium hexaboride (GdB6) were studied in comparison to a standard tungsten RILIS cavity as being routinely used for hot cavity laser ionization at ISOLDE. Measurement campaigns took place at the off-line mass separators at ISOLDE/CERN, Geneva and RISIKO/University of Mainz.

  2. Increase of the performances of electron cyclotron resonance ion sources by using cold electron emission

    CERN Document Server

    Schaechter, I; Badescu-Singureanu, A I; Stiebing, K E; Runkel, S; Hohn, O; Schmidt, L; Schmidt-Böcking, H; Drentje, A; Rodríguez, G

    2003-01-01

    The possibility of a significant increase of the high charge state ion beams delivered by electron cyclotron resonance (ECR) ion sources was approached in IFIN-HH, Bucharest, Romania by a new method. It consists in the introduction in the plasma chamber of the ECR ion source of a metal-dielectric (MD) structure characterized by very high secondary electron emission properties. The intensities of argon ion beams extracted from the 14 GHz ECR ion sources of IKF, Frankfurt/Main, Germany and KVI, Groningen, Netherlands were measured both in the standard mode of operation of the sources and in the presence of a MD structure. Similar results were obtained in both experiments when the MD structure was used showing a net shift of the beam intensity towards higher charge states as compared with the usual standard plasma chamber of the ECR ion sources. Ion current enhancement factors of up to two orders of magnitude were obtained for Ar sup 1 sup 6 sup + ions. (authors)

  3. A laser ion source with a thin ohmic-heating ionizer for the TIARA-ISOL

    CERN Document Server

    Koizumi, M; Oshima, M; Sekine, T; Wakui, T; Jin, W G; Katsuragawa, H; Miyatake, H; Ishida, Y

    2003-01-01

    An ohmic-heating laser ion source with a thin ionizer of thickness of 30 mu m has been developed for the TIARA-ISOL. It can form an electric field of 4-5 V/cm inside the ionizer. The properties of the laser ion source were tested on- and off-line with aluminum isotopes. The FWHM of the time distribution of the bunched photoions from the ion source was about 4 mu s for sup 2 sup 7 Al. In on-line experiment, a photoionization efficiency of about 0.1% for sup 2 sup 5 Al was obtained.

  4. Development of a multicusp H/sup -/ ion source for accelerator applications

    Energy Technology Data Exchange (ETDEWEB)

    York, R.L.; Stevens, R.R. Jr.

    1983-01-01

    The development of a multicusp surface-production H/sup -/ ion source (Berkeley concept) designed specifically for accelerator use is described. The goal of this development effort has been to provide a suitable H/sup -/ ion source for the Proton Storage Ring now being constructed at LAMPF. The ion source that has been developed is now capable of long-term operation at 20 mA of H/sup -/ current at 10% duty factor and with normalized beam emittance of 0.13 cm-mrad (95% beam fraction). The development program will be described with particular emphasis on beam emittance measurements.

  5. Study of back streaming ion using a slot-type grounded grid in hydrogen negative-ion source

    Science.gov (United States)

    Ikeda, K.; Kisaki, M.; Nakano, H.; Nagaoka, K.; Osakabe, M.; Kamio, S.; Tsumori, K.; Geng, S.; Takeiri, Y.

    2017-08-01

    The properties of cesium (Cs) recycling due to back-streaming ions have been investigated using an optical emission spec-troscopy in the hydrogen negative ion (H-) source with a slot-type grounded grid (GG). The slot-type GG performed well to enhance the beam performance, and to reduce the thermal loading on GG by high transparency. We clearly observed increase of Cs optical emission intensity during beam extraction owing to the increase of the Cs ions sputtered from the back plate of the source due to the back-streaming positive hydrogen ions. Increase of Cs is closely related with the extracted H- current, but it does not depend on the beam energy. Recycling Cs from the back plate is deeply relevant to the perveance condition of the H- beam, and is minimized at the optimum perveance. Strong Cs recycling from the back plate owing to the back-streaming ions is promoted in the high perveance condition with large divergence, which is consistent with the numerical calculation for the distribution of back streaming ions. This high Cs recycling condition, however, is not suitable for safety beam operation with high energy beam. The output of beam power is saturated by the space charge limitation, and divergent beam is trapped in the grounded grid (GG), which may cause damage on the slot-type GG surface by high thermal loading as large as in the aperture-type GG.

  6. Studies on a Q/A selector for the SECRAL electron cyclotron resonance ion source.

    Science.gov (United States)

    Yang, Y; Sun, L T; Feng, Y C; Fang, X; Lu, W; Zhang, W H; Cao, Y; Zhang, X Z; Zhao, H W

    2014-08-01

    Electron cyclotron resonance ion sources are widely used in heavy ion accelerators in the world because they are capable of producing high current beams of highly charged ions. However, the design of the Q/A selector system for these devices is challenging, because it must have a sufficient ion resolution while controlling the beam emittance growth. Moreover, this system has to be matched for a wide range of ion beam species with different intensities. In this paper, research on the Q/A selector system at the SECRAL (Superconducting Electron Cyclotron Resonance ion source with Advanced design in Lanzhou) platform both in experiment and simulation is presented. Based on this study, a new Q/A selector system has been designed for SECRAL II. The features of the new design including beam simulations are also presented.

  7. Atmospheric Pressure Chemical Ionization Sources Used in The Detection of Explosives by Ion Mobility Spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Waltman, Melanie J. [New Mexico Inst. of Mining and Technology, Socorro, NM (United States)

    2010-05-01

    Explosives detection is a necessary and wide spread field of research. From large shipping containers to airline luggage, numerous items are tested for explosives every day. In the area of trace explosives detection, ion mobility spectrometry (IMS) is the technique employed most often because it is a quick, simple, and accurate way to test many items in a short amount of time. Detection by IMS is based on the difference in drift times of product ions through the drift region of an IMS instrument. The product ions are created when the explosive compounds, introduced to the instrument, are chemically ionized through interactions with the reactant ions. The identity of the reactant ions determines the outcomes of the ionization process. This research investigated the reactant ions created by various ionization sources and looked into ways to manipulate the chemistry occurring in the sources.

  8. Performance on the low charge state laser ion source in BNL

    Energy Technology Data Exchange (ETDEWEB)

    Okamura, M.; Alessi, J.; Beebe, E.; Costanzo, M.; DeSanto, L.; Jamilkowski, J.; Kanesue, T.; Lambiase, R.; Lehn, D.; Liaw, C. J.; McCafferty, D.; Morris, J.; Olsen, R.; Pikin, A.; Raparia, D.; Steszyn, A.; Ikeda, S.

    2015-09-07

    On March 2014, a Laser Ion Source (LIS) was commissioned which delivers high-brightness, low-charge-state heavy ions for the hadron accelerator complex in Brookhaven National Laboratory (BNL). Since then, the LIS has provided many heavy ion species successfully. The low-charge-state (mostly singly charged) beams are injected to the Electron Beam Ion Source (EBIS), where ions are then highly ionized to fit to the following accelerator’s Q/M acceptance, like Au32+. Recently we upgraded the LIS to be able to provide two different beams into EBIS on a pulse-to-pulse basis. Now the LIS is simultaneously providing beams for both the Relativistic Heavy Ion Collider (RHIC) and NASA Space Radiation Laboratory (NSRL).

  9. Interlaboratory study of the ion source memory effect in {sup 36}Cl accelerator mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Pavetich, Stefan, E-mail: s.pavetich@hzdr.de [Helmholtz-Zentrum Dresden-Rossendorf, Bautzner Landstraße 400, 01314 Dresden (Germany); Akhmadaliev, Shavkat [Helmholtz-Zentrum Dresden-Rossendorf, Bautzner Landstraße 400, 01314 Dresden (Germany); Arnold, Maurice; Aumaître, Georges; Bourlès, Didier [Aix-Marseille Université, CEREGE CNRS-IRD, F-13545 Aix-en-Provence (France); Buchriegler, Josef [Helmholtz-Zentrum Dresden-Rossendorf, Bautzner Landstraße 400, 01314 Dresden (Germany); University of Vienna, Faculty of Physics, VERA Laboratory, Währingerstraße 17, 1090 Vienna (Austria); Golser, Robin [University of Vienna, Faculty of Physics, VERA Laboratory, Währingerstraße 17, 1090 Vienna (Austria); Keddadouche, Karim [Aix-Marseille Université, CEREGE CNRS-IRD, F-13545 Aix-en-Provence (France); Martschini, Martin [University of Vienna, Faculty of Physics, VERA Laboratory, Währingerstraße 17, 1090 Vienna (Austria); Merchel, Silke; Rugel, Georg [Helmholtz-Zentrum Dresden-Rossendorf, Bautzner Landstraße 400, 01314 Dresden (Germany); Steier, Peter [University of Vienna, Faculty of Physics, VERA Laboratory, Währingerstraße 17, 1090 Vienna (Austria)

    2014-06-01

    Highlights: • Long-term memory effect in negative ion sources investigated for chlorine isotopes. • Interlaboratory comparison of four up-to date negative ion sources. • Ion source improvement at DREAMS for minimization of long-term memory effect. • Long-term memory effect is the limitation for precise AMS data of volatile elements. • Findings to be considered for samples with highly variable ratios of {sup 36}Cl/Cl and {sup 129}I/I. - Abstract: Understanding and minimization of contaminations in the ion source due to cross-contamination and long-term memory effect is one of the key issues for accurate accelerator mass spectrometry (AMS) measurements of volatile elements. The focus of this work is on the investigation of the long-term memory effect for the volatile element chlorine, and the minimization of this effect in the ion source of the Dresden accelerator mass spectrometry facility (DREAMS). For this purpose, one of the two original HVE ion sources at the DREAMS facility was modified, allowing the use of larger sample holders having individual target apertures. Additionally, a more open geometry was used to improve the vacuum level. To evaluate this improvement in comparison to other up-to-date ion sources, an interlaboratory comparison had been initiated. The long-term memory effect of the four Cs sputter ion sources at DREAMS (two sources: original and modified), ASTER (Accélérateur pour les Sciences de la Terre, Environnement, Risques) and VERA (Vienna Environmental Research Accelerator) had been investigated by measuring samples of natural {sup 35}Cl/{sup 37}Cl-ratio and samples highly-enriched in {sup 35}Cl ({sup 35}Cl/{sup 37}Cl ∼ 999). Besides investigating and comparing the individual levels of long-term memory, recovery time constants could be calculated. The tests show that all four sources suffer from long-term memory, but the modified DREAMS ion source showed the lowest level of contamination. The recovery times of the four ion

  10. Composition analyzer for microparticles using a spark ion source

    Science.gov (United States)

    Auer, S.; Berg, O. E.

    1975-01-01

    Iron microparticles were fired onto a capacitor-type microparticle detector which responded to an impact with a spark discharge. Ion currents were extracted from the spark and analyzed in a time-of-flight mass spectrometer. The mass spectra showed the elements of both detector and particle materials. The total extracted ion current was typically 10 A within a period of 100 nsec, indicating very efficient vaporization of the particle and ionization of the vapor. Potential applications include research on cosmic dust, atmospheric aerosols and cloud droplets, particles ejected by rocket or jet engines, by machining processes or by nuclear bomb explosions.

  11. Simulation study of LEBT for transversely coupled beam from an ECR ion source.

    Science.gov (United States)

    Yang, Y; Dou, W P; Sun, L T; Yao, Q G; Zhang, Z M; Yuan, Y J; He, Y; Zh, X Z; Zhao, H W

    2016-02-01

    A Low-Energy intense-highly charged ion Accelerator Facility (LEAF) program has been launched at Institute of Modern Physics. This accelerator facility consists of a superconducting Electron Cyclotron Resonance (ECR) ion source, a Low Energy Beam Transport (LEBT) system, and a Radio Frequency Quadrupole (RFQ). It is especially of interest for the extracted ion beam from the ECR ion source, which is transversely coupled, and this property will significantly affect the beam transmission in the LEBT line and the matching with the downstream RFQ. In the beam transport design of LEAF, beam decoupling in the LEBT is considered to lower down the projection emittances and the feasibility of the design has been verified by beam simulation with a transversely coupled beam from the ECR ion source.

  12. Development of Electron Cyclotron Resonance Ion Source for Synthesis of Endohedral Metallofullerenes

    Science.gov (United States)

    Tanaka, K.; Muramatsu, M.; Uchida, T.; Biri, S.; Asaji, T.; Shima, K.; Hanajiri, T.; Kitagawa, A.; Kato, Y.; Yoshida, Y.

    2008-11-01

    A new electron cyclotron resonance ion source (ECRIS) has been constructed for synthesis of endohedral metallofullerenes. The main purpose of the ion source is to produce new biological and medical materials. The design is based on ECRIS for production of multicharged ion beams with a traditional minimum-B magnetic field. An 8-10 GHz traveling wave tube (TWT) amplifier and a 2.45 GHz magnetron have been applied as microwave sources. Fullerene and metal vapor are introduced with a filament heating micro-oven and an induction heating oven, respectively. In preliminary ion-extraction test, Ar+ is 54 μA. Many broken fullerenes such as C58 and C56 are observed in fullerene ion beams.

  13. A double-layer based model of ion confinement in electron cyclotron resonance ion source

    Science.gov (United States)

    Mascali, D.; Neri, L.; Celona, L.; Castro, G.; Torrisi, G.; Gammino, S.; Sorbello, G.; Ciavola, G.

    2014-02-01

    The paper proposes a new model of ion confinement in ECRIS, which can be easily generalized to any magnetic configuration characterized by closed magnetic surfaces. Traditionally, ion confinement in B-min configurations is ascribed to a negative potential dip due to superhot electrons, adiabatically confined by the magneto-static field. However, kinetic simulations including RF heating affected by cavity modes structures indicate that high energy electrons populate just a thin slab overlapping the ECR layer, while their density drops down of more than one order of magnitude outside. Ions, instead, diffuse across the electron layer due to their high collisionality. This is the proper physical condition to establish a double-layer (DL) configuration which self-consistently originates a potential barrier; this "barrier" confines the ions inside the plasma core surrounded by the ECR surface. The paper will describe a simplified ion confinement model based on plasma density non-homogeneity and DL formation.

  14. A double-layer based model of ion confinement in electron cyclotron resonance ion source

    Energy Technology Data Exchange (ETDEWEB)

    Mascali, D., E-mail: davidmascali@lns.infn.it; Neri, L.; Celona, L.; Castro, G.; Gammino, S.; Ciavola, G. [Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali del Sud, via S. Sofia 62, 95123 Catania (Italy); Torrisi, G. [Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali del Sud, via S. Sofia 62, 95123 Catania (Italy); Università Mediterranea di Reggio Calabria, Dipartimento di Ingegneria dell’Informazione, delle Infrastrutture e dell’Energia Sostenibile, Via Graziella, I-89100 Reggio Calabria (Italy); Sorbello, G. [Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali del Sud, via S. Sofia 62, 95123 Catania (Italy); Università degli Studi di Catania, Dipartimento di Ingegneria Elettrica Elettronica ed Informatica, Viale Andrea Doria 6, 95125 Catania (Italy)

    2014-02-15

    The paper proposes a new model of ion confinement in ECRIS, which can be easily generalized to any magnetic configuration characterized by closed magnetic surfaces. Traditionally, ion confinement in B-min configurations is ascribed to a negative potential dip due to superhot electrons, adiabatically confined by the magneto-static field. However, kinetic simulations including RF heating affected by cavity modes structures indicate that high energy electrons populate just a thin slab overlapping the ECR layer, while their density drops down of more than one order of magnitude outside. Ions, instead, diffuse across the electron layer due to their high collisionality. This is the proper physical condition to establish a double-layer (DL) configuration which self-consistently originates a potential barrier; this “barrier” confines the ions inside the plasma core surrounded by the ECR surface. The paper will describe a simplified ion confinement model based on plasma density non-homogeneity and DL formation.

  15. Assessment of Various Low Temperature Electrolytes in Prototype Li-Ion Cells Developed for ESMD Applications

    Science.gov (United States)

    Smart, M. C.; Ratnakumar, B. V.; Whitcanack, L. D.

    2008-01-01

    Due to their attractive properties and proven success, Li-ion batteries have become identified as the battery chemistry of choice for a number of future NASA missions. A number of these applications would be greatly benefited by improved performance of Li-ion technology over a wider operating temperature range, especially at low temperatures, such as future ESMD missions. In many cases, these technology improvements may be mission enabling, and at the very least mission enhancing. In addition to aerospace applications, the DoE has interest in developing advanced Li-ion batteries that can operate over a wide temperature range to enable terrestrial HEV applications. Thus, our focus at JPL in recent years has been to extend the operating temperature range of Li-ion batteries, especially at low temperatures. To accomplish this, the main focus of the research has been devoted to developing improved lithium-ion conducting electrolytes. In the present paper, we would like to present some of the results we have obtained with six different ethylene carbonate-based electrolytes optimized for low temperature. In addition to investigating the behavior in experimental cells initially, the performance of these promising low temperature electrolytes was demonstrated in large capacity, aerospace quality Li-ion prototype cells, manufactured by Yardney Technical Products and Saft America, Inc. These cells were subjected to a number of performance tests, including discharge rate characterization, charge rate characterization, cycle life performance at various temperatures, and power characterization tests.

  16. Analysis of particle production in ultrarelativistic heavy-ion collisions within a two-source statistical model

    CERN Document Server

    Zhong Dao Lu; Fuchs, C; Zabrodin, E E; 10.1103/PhysRevC.66.044905

    2002-01-01

    The experimental data on hadron yields and ratios in central lead- lead and gold-gold collisions at 158A GeV/c (SPS) and square root s =130A GeV (RHIC), respectively, are analyzed within a two-source statistical model of an ideal hadron gas. A comparison with the standard thermal model is given. The two sources, which can reach the chemical and thermal equilibrium separately and may have different temperatures, particle and strangeness densities, and other thermodynamic characteristics, represent the expanding system of colliding heavy ions, where the hot central fireball is embedded in a larger but cooler fireball. The volume of the central source increases with rising bombarding energy. Results of the two-source model fit to RHIC experimental data at midrapidity coincide with the results of the one-source thermal model fit, indicating the formation of an extended fireball, which is three times larger than the corresponding core at SPS. (49 refs).

  17. Summary I - accelerator ion sources, fundamentals and diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Moehs, Douglas P.; /Fermilab

    2006-10-01

    The 11th International Symposium on the Production and Neutralization of Negative Ions and Beams was held in Santa Fe, New Mexico on September 12-15, 2006 and was hosted by Los Alamos National Laboratory. This summary covers the first three oral sessions of the symposium.

  18. The development of data acquisition and processing application system for RF ion source

    Science.gov (United States)

    Zhang, Xiaodan; Wang, Xiaoying; Hu, Chundong; Jiang, Caichao; Xie, Yahong; Zhao, Yuanzhe

    2017-07-01

    As the key ion source component of nuclear fusion auxiliary heating devices, the radio frequency (RF) ion source is developed and applied gradually to offer a source plasma with the advantages of ease of control and high reliability. In addition, it easily achieves long-pulse steady-state operation. During the process of the development and testing of the RF ion source, a lot of original experimental data will be generated. Therefore, it is necessary to develop a stable and reliable computer data acquisition and processing application system for realizing the functions of data acquisition, storage, access, and real-time monitoring. In this paper, the development of a data acquisition and processing application system for the RF ion source is presented. The hardware platform is based on the PXI system and the software is programmed on the LabVIEW development environment. The key technologies that are used for the implementation of this software programming mainly include the long-pulse data acquisition technology, multi-threading processing technology, transmission control communication protocol, and the Lempel-Ziv-Oberhumer data compression algorithm. Now, this design has been tested and applied on the RF ion source. The test results show that it can work reliably and steadily. With the help of this design, the stable plasma discharge data of the RF ion source are collected, stored, accessed, and monitored in real-time. It is shown that it has a very practical application significance for the RF experiments.

  19. RADI-A RF source size-scaling experiment towards the ITER neutral beam negative ion source

    Energy Technology Data Exchange (ETDEWEB)

    Franzen, P. [Max-Planck-Institut fuer Plasmaphysik, EURATOM Association, Postfach 1533, D-85740 Garching (Germany)], E-mail: peter.franzen@ipp.mpg.de; Falter, H.; Heinemann, B.; Martens, Ch.; Fantz, U.; Berger, M.; Christ-Koch, S.; Froeschle, M.; Holtum, D.; Kraus, W.; Leyer, S.; McNeely, P.; Riedl, R.; Suess, R.; Obermayer, S.; Speth, E.; Wuenderlich, D. [Max-Planck-Institut fuer Plasmaphysik, EURATOM Association, Postfach 1533, D-85740 Garching (Germany)

    2007-06-15

    IPP Garching is currently developing a negative hydrogen ion RF source for the ITER neutral beam system. The source demonstrated already current densities in excess of the ITER requirements (>200 A/m{sup 2} D{sup -}) at the required source pressure and electron/ion ratio, but with only small extraction area and limited pulse length. A new test facility (RADI) went recently into operation for the demonstration of the required (plasma) homogeneity of a large RF source and the modular driver concept. The source with the dimension of 0.8 m x 0.76 m has roughly the width and half the height of the ITER source; its modular driver concept will allow an easy extrapolation in only one direction to the full size ITER source. The RF power supply consists of two 180 kW, 1 MHz RF generators capable of 30 s pulses. A dummy grid matches the conductance of the ITER source. Full size extraction is presently not possible due to the lack of an insulator, a large size extraction system and a beam dump. The main parameters determining the performance of this 'half-size' source are the negative ion and electron density in front of the grid as well as the homogeneity of their profiles across the grid. Those will be measured by optical emission and cavity ring down spectroscopy, by Langmuir probes and laser detachment. These methods have been calibrated to the extracted current densities achieved at the smaller source test facilities at IPP for similar source parameters. However, in order to get some information about the possible ion and electron currents, local single aperture extraction with a Faraday cup system is planned.

  20. Comparison of extraction and beam transport simulations with emittance measurements from the ECR ion source venus

    Energy Technology Data Exchange (ETDEWEB)

    Winklehner, D; Todd, D; Benitez, J; Strohmeier, M; Leitner, D [Nuclear Science Division, Lawrence Berkeley National Laboratory, 1 Cyclotron Rd, Berkeley (United States); Grote, D, E-mail: winklehner@frib.msu.ed [Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore (United States)

    2010-12-15

    The versatility of ECR (Electron Cyclotron Resonance) ion sources makes them the injector of choice for many heavy ion accelerators. However, the design of the LEBT (Low Energy Beam Transport) systems for these devices is challenging, because it has to be matched for a wide variety of ions. In addition, due to the magnetic confinement fields, the ion density distribution across the extraction aperture is inhomogeneous and charge state dependent. In addition, the ion beam is extracted from a region of high axial magnetic field, which adds a rotational component to the beam. In this paper the development of a simulation model (in particular the initial conditions at the extraction aperture) for ECR ion source beams is described. Extraction from the plasma and transport through the beam line are then simulated with the particle-in-cell code WARP. Simulations of the multispecies beam containing Uranium ions of charge state 18+ to 42+ and oxygen ions extracted from the VENUS ECR ion source are presented and compared to experimentally obtained emittance values.

  1. Enhanced highly charged ion production using a metal-dielectric liner in the KVI 14 GHz ECR ion source

    NARCIS (Netherlands)

    Schachter, L; Dobrescu, S; Rodrigues, G; Drentje, AG

    Forming on an aluminum surface a dielectric layer of alumina (aluminum oxide) in order to create a metal-dielectric (MD) structure increases the secondary-electron emission properties. The idea of using this material as a MD (Al-Al2O3) cylindrical liner inside an ECR ion source was previously tested

  2. High electronegativity multi-dipolar electron cyclotron resonance plasma source for etching by negative ions

    DEFF Research Database (Denmark)

    Stamate, Eugen; Draghici, M.

    2012-01-01

    A large area plasma source based on 12 multi-dipolar ECR plasma cells arranged in a 3 x 4 matrix configuration was built and optimized for silicon etching by negative ions. The density ratio of negative ions to electrons has exceeded 300 in Ar/SF6 gas mixture when a magnetic filter was used to re...

  3. Experiments with biased cylinder in electron cyclotron resonance ion source (plenary)

    NARCIS (Netherlands)

    Drentje, AG; Kitagawa, A; Muramatsu, M; Ogawa, H; Sakamoto, Y

    The shape of the magnetic field of an electron cyclotron resonance ion source (ECRIS) gives rise to different particle fluxes (losses) from the plasma to the end plates (mainly diffusion of electrons), and to the side walls (mainly ions). The electron fluxes to the injection end plate can be reduced

  4. Letter: A simple ion source set-up for desorption/ionization on silicon with ion mobility spectrometry and ion mobility spectrometry-mass spectrometry.

    Science.gov (United States)

    Adamov, Alexey; Sysoev, Alexey A; Grigoras, Kestutis; Laakia, Jaako; Kotiaho, Tapio

    2011-01-01

    Using a simple ion source set-up, laser desorption/ionization on silicon (DIOS) was demonstrated with the use of a custom-made drift tube ion mobility spectrometer (IMS), mounted on a commercial triple quadrupole mass spectrometer, and with an IMS equipped with a Faraday plate detector. DIOS was tested by mobility measurement of tetrapropylammonium iodide, tetrabutylammonium iodide and tetrapentylammonium iodide, whilst 2,6-di-tert- butylpyridine was used as a standard. The reduced mobilities measured for the test halides are in concordance with previously obtained ion mobility spectrometry-mass spectrometry data.

  5. Very Large Area/Volume Microwave ECR Plasma and Ion Source

    Science.gov (United States)

    Foster, John E. (Inventor); Patterson, Michael J. (Inventor)

    2009-01-01

    The present invention is an apparatus and method for producing very large area and large volume plasmas. The invention utilizes electron cyclotron resonances in conjunction with permanent magnets to produce dense, uniform plasmas for long life ion thruster applications or for plasma processing applications such as etching, deposition, ion milling and ion implantation. The large area source is at least five times larger than the 12-inch wafers being processed to date. Its rectangular shape makes it easier to accommodate to materials processing than sources that are circular in shape. The source itself represents the largest ECR ion source built to date. It is electrodeless and does not utilize electromagnets to generate the ECR magnetic circuit, nor does it make use of windows.

  6. Development of target ion source systems for radioactive beams at GANIL

    Energy Technology Data Exchange (ETDEWEB)

    Bajeat, O., E-mail: bajeat@ganil.fr [GANIL, BP 55027, 14076 CAEN Cedex 05 (France); Delahaye, P. [GANIL, BP 55027, 14076 CAEN Cedex 05 (France); Couratin, C. [GANIL, BP 55027, 14076 CAEN Cedex 05 (France); LPC Caen, 6 bd Maréchal Juin, 14050 CAEN Cedex (France); Dubois, M.; Franberg-Delahaye, H.; Henares, J.L.; Huguet, Y.; Jardin, P.; Lecesne, N.; Lecomte, P.; Leroy, R.; Maunoury, L.; Osmond, B.; Sjodin, M. [GANIL, BP 55027, 14076 CAEN Cedex 05 (France)

    2013-12-15

    Highlights: • For Spiral 1, a febiad ion source has been connected to a graphite target. • For Spiral 2, an oven made with a carbon resistor is under development. • We made some measurement of effusion in the Spiral 2 target. • A laser ion source is under construction. -- Abstract: The GANIL facility (Caen, France) is dedicated to the acceleration of heavy ion beams including radioactive beams produced by the Isotope Separation On-Line (ISOL) method at the SPIRAL1 facility. To extend the range of radioactive ion beams available at GANIL, using the ISOL method two projects are underway: SPIRAL1 upgrade and the construction of SPIRAL2. For SPIRAL1, a new target ion source system (TISS) using the VADIS FEBIAD ion source coupled to the SPIRAL1 carbon target will be tested on-line by the end of 2013 and installed in the cave of SPIRAL1 for operation in 2015. The SPIRAL2 project is under construction and is being design for using different production methods as fission, fusion or spallation reactions to cover a large area of the chart of nuclei. It will produce among others neutron rich beams obtained by the fission of uranium induced by fast neutrons. The production target made from uranium carbide and heated at 2000 °C will be associated with several types of ion sources. Developments currently in progress at GANIL for each of these projects are presented.

  7. A low-voltage, high-current, ion-bombardment source using magnetron principles

    Energy Technology Data Exchange (ETDEWEB)

    Ja' fer, H.A.; Howson, R.P. (Loughborough Univ of Technology (United Kingdom). Dept. of Physics)

    The operation of an unbalanced magnetron under conditions using extra electron injection is shown to be a source of plasma beam which can give a substrate a self-bias of between 25 and 100 V, and allow total ion-currents of over one ampere to be drawn to a target. The use of the device to give low-energy, ion-bombardment of a growing films and to form a dense plasma source for low voltage sputtering is reported. (Author).

  8. Development of a 10 GHz “Multi-Mode” ECR, Ion Source for the Production of Multiply Charged Ions from Metallic Elements

    Science.gov (United States)

    Trassl, R.; Thompson, W. R.; Broetz, F.; Pawlowsky, M.; McCullough, R. W.; Salzborn, E.

    An all-permanent magnet ECR “multi-mode” ion source with emphasis on the production of metallic ions has been built. The main feature of this ion source is a stepped plasma chamber with a larger diameter in the resonance region in order to allow the propagation of higher microwave modes than the ground mode. Ions from metallic elements can be produced using both the insertion technique and an evaporation oven. First spectra obtained for Oxygen and Bismuth are shown.

  9. Application and development of ion-source technology for radiation-effects testing of electronics

    Science.gov (United States)

    Kalvas, T.; Javanainen, A.; Kettunen, H.; Koivisto, H.; Tarvainen, O.; Virtanen, A.

    2017-09-01

    Studies of heavy-ion induced single event effect (SEE) on space electronics are necessary to verify the operation of the components in the harsh radiation environment. These studies are conducted by using high-energy heavy-ion beams to simulate the radiation effects in space. The ion beams are accelerated as so-called ion cocktails, containing several ion beam species with similar mass-to-charge ratio, covering a wide range of linear energy transfer (LET) values also present in space. The use of cocktails enables fast switching between beam species during testing. Production of these high-energy ion cocktails poses challenging requirements to the ion sources because in most laboratories reaching the necessary beam energies requires very high charge state ions. There are two main technologies producing these beams: The electron beam ion source EBIS and the electron cyclotron resonance ion source ECRIS. The EBIS is most suitable for pulsed accelerators, while ECRIS is most suitable for use with cyclotrons, which are the most common accelerators used in these applications. At the Accelerator Laboratory of the University of Jyväskylä (JYFL), radiation effects testing is currently performed using a K130 cyclotron and a 14 GHz ECRIS at a beam energy of 9.3 MeV/u. A new 18 GHz ECRIS, pushing the limits of the normal conducting ECR technology is under development at JYFL. The performances of existing 18 GHz ion sources have been compared, and based on this analysis, a 16.2 MeV/u beam cocktail with 1999 MeV 126Xe44+ being the most challenging component to has been chosen for development at JYFL. The properties of the suggested beam cocktail are introduced and discussed.

  10. Effects of ion-fluid temperature on dust-ion-acoustic solitons

    Indian Academy of Sciences (India)

    The properties of dust-ion-acoustic (DIA) solitons in an unmagnetized dusty plasma, whose constituents are adiabatic ion-fluid, Boltzmann electrons, and static dust particles, are investigated by employing the reductive perturbation method. The Korteweg-de Vries equation is derived and its stationary solution is numerically ...

  11. COMPLIS: COllinear spectroscopy Measurements using a Pulsed Laser Ion Source

    CERN Multimedia

    2002-01-01

    A Pulsed Laser spectroscopy experiment has been installed for the study of hyperfine structure and isotope shift of refractory and daughter elements from ISOLDE beams. It includes decelerated ion-implantation, element-selective laser ionization, magnetic and time-of-flight mass separation. The laser spectroscopy has been performed on the desorbed atoms in a set-up at ISOLDE-3 but later on high resolution laser collinear spectroscopy with the secondary pulsed ion beam is planned for the Booster ISOLDE set-up. During the first operation time of ISOLDE-3 we restricted our experiments to Doppler-limited resonant ionization laser and $\\gamma$-$\\gamma$ nuclear spectroscopy on neutron deficient platinum isotopes of even mass number down to A~=~186 and A~=~179 respectively. These isotopes have been produced by implantation of radioactive Hg and their subsequent $\\beta$-decay.

  12. VUV Absorption Spectroscopy of a Penning Surface - Negative Hydrogen Ion Source

    Science.gov (United States)

    Pitcher, Eric John

    The demand for energetic, high-current H ^- beams is ever-growing. Because H ^- is efficiently neutralized at high energies, these beams are ideally suited to applications where energetic neutral beams of particles are required to propagate across magnetic fields. Prime examples are neutral-beam heating of magnetic fusion plasmas and directed-energy weapons for ballistic missile defense. Such applications place demanding requirements on sources of H^ - ions, particularly with respect to the parameters of beam current, brightness, quiescence, reliability, and duty-factor. A class of sources that holds great promise for meeting these stringent requirements is the surface-plasma source (SPS), and in particular, the Penning type of SPS. It has long been conjectured that atomic hydrogen plays an important role in both H^- formation and transport in these sources. Understanding the interdependence of atomic hydrogen properties and those of H^ -, and how this relationship might be exploited to improve source performance is the motivation for this research. An overview of SPS's is presented. Previous measurements on the discharge are reviewed. Absorption spectroscopy, the diagnostic technique used to gather all of the data presented here, is discussed. Techniques that may potentially be used to measure the properties of H^ - in the discharge are discussed. The two absorption spectrometers used in this experiment are described. Measurements of ground-state atomic hydrogen density and temperature in a Penning SPS are presented. These measurements are the first of this kind for this type of discharge. An upper limit on the H^- density in the extraction region of the source is measured by the application of a novel diagnostic technique: the hydrogen atom density following H^- photodetachment by a Nd:YAG beam is measured and compared to the equilibrium atomic density. A simple model is derived that describes the dependence of the atomic temperature on the externally

  13. Temperature dependence of ion diffusion coefficients in NaCl electrolyte confined within graphene nanochannels.

    Science.gov (United States)

    Kong, Jing; Bo, Zheng; Yang, Huachao; Yang, Jinyuan; Shuai, Xiaorui; Yan, Jianhua; Cen, Kefa

    2017-03-15

    The behavior of ion diffusion in nano-confined spaces and its temperature dependence provide important fundamental information about electric double-layer capacitors (EDLCs) employing nano-sized active materials. In this work, the ion diffusion coefficients of NaCl electrolyte confined within neutral and charged graphene nanochannels at different temperatures are investigated using molecular dynamics simulations. The results show that ions confined in neutral nanochannels diffuse faster (along the graphene surfaces) than those in bulk solution, which could be attributed to the relatively smaller concentration in confined spaces and the solvophobic nature of graphene surfaces. In charged nanochannels where the electrostatic interactions between counter-ions and charged channel surfaces govern the motion of ions, the diffusion coefficients are found to be lower than those in the neutral counterparts. The increase of temperature will lead to enhanced vibrant thermal motion of ions. Due to the significant role of ion-surface interactions, ion diffusion coefficients in nano-confined spaces are more stable, that is, insensitive to the temperature variation, than those in bulk solution. The electrical conductivity is further estimated using the Nernst-Einstein equation. The findings of the current work could provide basic data and information for research studies on the thermal effects of graphene-based EDLCs.

  14. Extended Tonks-Langmuir-type model with non-Boltzmann-distributed electrons and cold ion sources

    Science.gov (United States)

    Kamran, M.; Kuhn, S.; Tskhakaya, D. D.; Khan, M.; Khan

    2013-04-01

    A general formalism for calculating the potential distribution Φ(z) in the quasineutral region of a new class of plane Tonks-Langmuir (TL)-type bounded-plasma-system (BPS) models differing from the well-known `classical' TL model (Tonks, L. and Langmuir, I. 1929 A general theory of the plasma of an arc. Phys. Rev. 34, 876) by allowing for arbitrary (but still cold) ion sources and arbitrary electron distributions is developed. With individual particles usually undergoing microscopic collision/sink/source (CSS) events, extensive use is made here of the basic kinetic-theory concept of `CSS-free trajectories' (i.e., the characteristics of the kinetic equation). Two types of electron populations, occupying the `type-t' and `type-p' domains of electron phase space, are distinguished. By definition, the type-t and type-p domains are made up of phase points lying on type-t (`trapped') CSS-free trajectories (not intersecting the walls and closing on themselves) and type-p (`passing') ones (starting at one of the walls and ending at the other). This work being the first step, it is assumed that ɛ ≡ λ D /l -> 0+ (where λ D and l are a typical Debye length and a typical ionization length respectively) so that the system exhibits a finite quasineutral `plasma' region and two infinitesimally thin `sheath' regions associated with the `sheath-edge singularities' | dΦ/dz| z->+/-zs -> ∞. The potential in the plasma region is required to satisfy a plasma equation (quasineutrality condition) of the form n i {Φ} = n e (Φ), where the electron density n e (Φ) is given and the ion density n i {Φ} is expressed in terms of trajectory integrals of the ion kinetic equation, with the ions produced by electron-impact ionization of cold neutrals. While previous TL-type models were characterized by electrons diffusing under the influence of frequent collisions with the neutral background particles and approximated by Maxwellian (Riemann, K.-U. 2006 Plasma-sheath transition in the

  15. Plasma rotation and ion temperature measurements by collective Thomson scattering at ASDEX Upgrade

    DEFF Research Database (Denmark)

    Stejner Pedersen, Morten; Nielsen, Stefan Kragh; Jacobsen, Asger Schou

    2015-01-01

    We present the first deuterium ion temperature and rotation measurements by collective Thomson scattering at ASDEX Upgrade. The results are in general agreement with boron-based charge exchange recombination spectroscopy measurements and consistent with neoclassical simulations for the plasma...

  16. Status of the Bio-Nano electron cyclotron resonance ion source at Toyo University

    Energy Technology Data Exchange (ETDEWEB)

    Uchida, T., E-mail: uchida-t@toyo.jp [Bio-Nano Electronics Research Centre, Toyo University, Kawagoe 350-8585 (Japan); Minezaki, H.; Ishihara, S. [Graduate School of Engineering, Toyo University, Kawagoe 350-8585 (Japan); Muramatsu, M.; Kitagawa, A.; Drentje, A. G. [National Institute of Radiological Sciences (NIRS), Chiba 263-8555 (Japan); Rácz, R.; Biri, S. [Institute for Nuclear Research (ATOMKI), H-4026 Debrecen (Hungary); Asaji, T. [Oshima National College of Maritime Technology, Yamaguchi 742-2193 (Japan); Kato, Y. [Graduate School of Engineering, Osaka University, Suita 565-0871 (Japan); Yoshida, Y. [Bio-Nano Electronics Research Centre, Toyo University, Kawagoe 350-8585 (Japan); Graduate School of Engineering, Toyo University, Kawagoe 350-8585 (Japan)

    2014-02-15

    In the paper, the material science experiments, carried out recently using the Bio-Nano electron cyclotron resonance ion source (ECRIS) at Toyo University, are reported. We have investigated several methods to synthesize endohedral C{sub 60} using ion-ion and ion-molecule collision reaction in the ECRIS. Because of the simplicity of the configuration, we can install a large choice of additional equipment in the ECRIS. The Bio-Nano ECRIS is suitable not only to test the materials production but also to test technical developments to improve or understand the performance of an ECRIS.

  17. Negative ion RF sources for ITER NBI: status of the development and recent achievements

    Energy Technology Data Exchange (ETDEWEB)

    Fantz, U; Franzen, P; Kraus, W; Berger, M; Christ-Koch, S; Froeschle, M; Gutser, R; Heinemann, B; Martens, C; McNeely, P; Riedl, R; Speth, E; Wuenderlich, D [Max-Planck-Insitut fuer Plasmaphysik, EURATOM Association, Boltzmannstrasse 2, D-85748 Garching (Germany)

    2007-12-15

    For heating and current drive the neutral beam injection system for ITER requires a deuterium beam with an energy of 1 MeV for up to 1 h. In order to inject the required 17 MW the ion source has to deliver 40 A of negative ion current. For an accelerated current density of 200 A m{sup -2} at the specified source pressure of 0.3 Pa the extraction area is 0.2 m{sup 2} resulting in a large area source of 1.5 x 0.6 m{sup 2}. Two types of sources have been under discussion, the filamented arc source and the inductively driven RF source, the latter now having been chosen for the ITER reference design. The development of negative ion RF sources, which fulfil these specifications is being carried out at the Max-Planck-Institut fuer Plasmaphysik at three test facilities in parallel. The required current densities at the ITER relevant pressure have been achieved and even exceeded in a test facility equipped with a small ion source (extraction area of 0.007 m{sup 2}) at limited pulse length (<4 s). The extraction area can be extended up to 0.03 m{sup 2} and the pulse length up to 3600 s at a second test facility which is dedicated to long pulse operation experiments where pulses up to 800 s have already been achieved. The ion source at the third test facility has roughly the full width and half the height of the ITER source but is not equipped with an extraction system. The aim is to demonstrate the size scaling and plasma homogeneity of RF ion sources. First results from different diagnostic techniques (optical emission spectroscopy and Langmuir probe) are very promising.

  18. Calculating method for confinement time and charge distribution of ions in electron cyclotron resonance sources

    Energy Technology Data Exchange (ETDEWEB)

    Dougar-Jabon, V.D. [Escuela de Fisica, Universidad Industrial de Santander, A.A. 678, Bucaramanga (Colombia); Umnov, A.M. [Russian Friendship University, 117198 Moscow (Russia); Kutner, V.B. [Joint Institute for Nuclear Research, Dubna (Russia)

    1996-03-01

    It is common knowledge that the electrostatic pit in a core plasma of electron cyclotron resonance sources exerts strict control over generation of ions in high charge states. This work is aimed at finding a dependence of the lifetime of ions on their charge states in the core region and to elaborate a numerical model of ion charge dispersion not only for the core plasmas but for extracted beams as well. The calculated data are in good agreement with the experimental results on charge distributions and magnitudes for currents of beams extracted from the 14 GHz DECRIS source. {copyright} {ital 1996 American Institute of Physics.}

  19. Generation of oxygen, carbon and metallic ion beams by a compact microwave source

    Energy Technology Data Exchange (ETDEWEB)

    Walther, S.R.; Leung, K.N.; Ehlers, K.W.; Kunkel, W.B.

    1986-07-01

    A small microwave ion source fabricated from a quartz tube and enclosed externally by a cavity has been operated with different geometries and for various gases in a cw mode. This source has been used to generate oxygen ion beams with energy as low as 5.5 eV. Beam energy spread has been measured to be less than 1 eV. By installing different metal plates on the front extraction electrode, metallic ion beams such as (Be, Cu, Al, etc.) can be produced.

  20. The study towards high intensity high charge state laser ion sources.

    Science.gov (United States)

    Zhao, H Y; Jin, Q Y; Sha, S; Zhang, J J; Li, Z M; Liu, W; Sun, L T; Zhang, X Z; Zhao, H W

    2014-02-01

    As one of the candidate ion sources for a planned project, the High Intensity heavy-ion Accelerator Facility, a laser ion source has been being intensively studied at the Institute of Modern Physics in the past two years. The charge state distributions of ions produced by irradiating a pulsed 3 J/8 ns Nd:YAG laser on solid targets of a wide range of elements (C, Al, Ti, Ni, Ag, Ta, and Pb) were measured with an electrostatic ion analyzer spectrometer, which indicates that highly charged ions could be generated from low-to-medium mass elements with the present laser system, while the charge state distributions for high mass elements were relatively low. The shot-to-shot stability of ion pulses was monitored with a Faraday cup for carbon target. The fluctuations within ±2.5% for the peak current and total charge and ±6% for pulse duration were demonstrated with the present setup of the laser ion source, the suppression of which is still possible.

  1. Effect of axial magnetic field on a 2.45 GHz permanent magnet ECR ion source

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, T., E-mail: tsubasa@oshima-k.ac.jp; Wada, H.; Furuse, M. [National Institute of Technology, Oshima College, 1091-1 Komatsu, Suouoshima, Oshima, Yamaguchi 742-2193 (Japan); Asaji, T. [National Institute of Technology, Toyama College, 13 Hongo, Toyama 939-8630 (Japan)

    2016-02-15

    Herein, we conduct a fundamental study to improve the generation efficiency of a multi-charged ion source using argon. A magnetic field of our electron cyclotron resonance ion source is composed of a permanent magnet and a solenoid coil. Thereby, the axial magnetic field in the chamber can be tuned. Using the solenoid coil, we varied the magnetic field strength in the plasma chamber and measured the ion beam current extracted at the electrode. We observed an approximately three times increase in the Ar{sup 4+} ion beam current when the magnetic field on the extractor-electrode side of the chamber was weakened. From our results, we can confirm that the multi-charged ion beam current changes depending on magnetic field intensity in the plasma chamber.

  2. Corrosion behaviour of low energy, high temperature nitrogen ion ...

    Indian Academy of Sciences (India)

    S FLEGE. Technische Universität Darmstadt, Materials Science, Petersenstr. 23, 64287 Darmstadt, Germany. E-mail: flege@ca.tu-darmstadt.de. Ghoranneviss et al [1] have reported on nitrogen implantation into stainless steel and presented a secondary ion mass spectrometry (SIMS) measurement of the N and the CrN.

  3. Quarkonia at finite temperature in relativistic heavy-ion collisions

    Indian Academy of Sciences (India)

    2015-05-06

    May 6, 2015 ... ... is reviewed. After a detailed discussion of the current theoretical understanding of quarkonia in a static equilibriated plasma, we discuss quarkonia yield from the fireball created in ultrarelativistic heavy-ion collision experiments. We end with a brief discussion of the experimental results and outlook.

  4. Effect of nonthermal ion distribution and dust temperature on ...

    Indian Academy of Sciences (India)

    the investigation of nonlinear dust acoustic waves in an unmagnetized dusty plasma. Sagdeev pseu- dopotential ... Solitons; dust acoustic wave; Sagdeev potential; dusty plasma; nonthermal ion. PACS No. 52.25. 1. ... ties of large amplitude stationary dust acoustic solitons, we assume that all the dependent variables in ...

  5. Bipolar ionization source for ion mobility spectrometry based on vacuum ultraviolet radiation induced photoemission and photoionization.

    Science.gov (United States)

    Chen, Chuang; Dong, Can; Du, Yongzhai; Cheng, Shasha; Han, Fenglei; Li, Lin; Wang, Weiguo; Hou, Keyong; Li, Haiyang

    2010-05-15

    A novel bipolar ionization source based on a commercial vacuum-UV Kr lamp has been developed for ion mobility spectrometry (IMS), which can work in both negative and positive ion mode. Its reactant ions formed in negative ion mode were predominantly assigned to be O(3)(-)(H(2)O)(n), which is different from that of the (63)Ni source with purified air as carrier and drift gases. The formation of O(3)(-)(H(2)O)(n) was due to the production of ozone caused by ultraviolet radiation, and the ozone concentration was measured to be about 1700 ppmv by iodometric titration method. Inorganic molecules such as SO(2), CO(2), and H(2)S can be easily detected in negative ion mode, and a linear dynamic range of 3 orders of magnitude and a limit of detection (S/N = 3) of 150 pptv were obtained for SO(2). Its performance as a negative ion source was investigated by the detection of ammonium nitrate fuel oil explosive, N-nitrobis(2-hydroxyethyl)amine dinitrate, cyclo-1,3,5-trimethylene-2,4,6-trinitramine, and pentaerythritol tetranitrate (PETN) at 150 degrees C. The limit of detection was reached at 45 pg for PETN, which was much lower than the 190 pg using (63)Ni ion mobility spectrometry under the same experimental condition. Also, its performance as an ordinary photoionization source was investigated in detecting benzene, toluene, and m-xylene.

  6. Super-atmospheric pressure electrospray ion source: applied to aqueous solution.

    Science.gov (United States)

    Chen, Lee Chuin; Mandal, Mridul Kanti; Hiraoka, Kenzo

    2011-12-01

    This is a follow-up paper of our previous report on an ion source, which was operated at an operating pressure higher than the atmospheric pressure. Besides having more working gas for desolvation, the reduction of mean free path of electrons in a higher pressure environment increases the threshold voltage for gaseous breakdown, thus enabling a stable electrospray for the sample solution with high surface tension without the occurrence of electric discharge. In our previous work, the ion source was not coupled directly to the mass spectrometer and significant amount of ions were lost before entering the vacuum of the mass spectrometer. In this paper, we report the new design of our second prototype in which, by using a modified ion transport capillary, the pressurized ESI ion source was coupled directly to the first pumping stage of the mass spectrometer without additional modification on the vacuum pumping system. Demonstrations of the new ion source on the sensitive detection of native proteins from aqueous solution in both positive and negative ion modes are presented. © American Society for Mass Spectrometry, 2011

  7. Hot-cavity studies for the Resonance Ionization Laser Ion Source

    Energy Technology Data Exchange (ETDEWEB)

    Henares, J.L., E-mail: henares@ganil.fr [GANIL, BP 55027, 14076 Caen Cedex 5 (France); Lecesne, N.; Hijazi, L.; Bastin, B. [GANIL, BP 55027, 14076 Caen Cedex 5 (France); Kron, T. [Johannes Gutenberg-Universität Mainz, Staudinger Weg 7, 55099 Mainz (Germany); Lassen, J. [TRIUMF, 4004 Wesbrook Mall, Vancouver, BC, Canada V6T 2A3 (Canada); Le Blanc, F. [IPN Orsay, BP 1-91406 Orsay (France); Leroy, R.; Osmond, B. [GANIL, BP 55027, 14076 Caen Cedex 5 (France); Raeder, S. [Johannes Gutenberg-Universität Mainz, Staudinger Weg 7, 55099 Mainz (Germany); KU Leuven, Oude Markt 13, 3000 Leuven (Belgium); Schneider, F.; Wendt, K. [Johannes Gutenberg-Universität Mainz, Staudinger Weg 7, 55099 Mainz (Germany)

    2016-09-11

    The Resonance Ionization Laser Ion Source (RILIS) has emerged as an important technique in many Radioactive Ion Beam (RIB) facilities for its reliability, and ability to ionize target elements efficiently and element selectively. GISELE is an off-line RILIS test bench to study the implementation of an on-line laser ion source at the GANIL separator facility. The aim of this project is to determine the best technical solution which combines high selectivity and ionization efficiency with small ion beam emittance and stable long term operation. The ion source geometry was tested in several configurations in order to find a solution with optimal ionization efficiency and beam emittance. Furthermore, a low work function material was tested to reduce the contaminants and molecular sidebands generated inside the ion source. First results with ZrC ionizer tubes will be presented. Furthermore, a method to measure the energy distribution of the ion beam as a function of the time of flight will be discussed.

  8. Ion temperature effects on magnetotail Alfvén wave propagation and electron energization: ION TEMPERATURE EFFECTS ON ALFVÉN WAVES

    Energy Technology Data Exchange (ETDEWEB)

    Damiano, P. A. [Princeton Center for Heliophysics, Princeton Plasma Physics Laboratory, Princeton University, Princeton New Jersey USA; Johnson, J. R. [Princeton Center for Heliophysics, Princeton Plasma Physics Laboratory, Princeton University, Princeton New Jersey USA; Chaston, C. C. [Space Sciences Laboratory, University of California, Berkeley California USA; School of Physics, University of Sydney, Sydney New South Wales Australia

    2015-07-01

    A new 2-D self-consistent hybrid gyrofluid-kinetic electron model in dipolar coordinates is presented and used to simulate dispersive-scale Alfvén wave pulse propagation from the equator to the ionosphere along an L = 10 magnetic field line. The model is an extension of the hybrid MHD-kinetic electron model that incorporates ion Larmor radius corrections via the kinetic fluid model of Cheng and Johnson (1999). It is found that consideration of a realistic ion to electron temperature ratio decreases the propagation time of the wave from the plasma sheet to the ionosphere by several seconds relative to a ρi=0 case (which also implies shorter timing for a substorm onset signal) and leads to significant dispersion of wave energy perpendicular to the ambient magnetic field. Additionally, ion temperature effects reduce the parallel current and electron energization all along the field line for the same magnitude perpendicular electric field perturbation.

  9. Nb3Sn superconducting magnets for electron cyclotron resonance ion sources.

    Science.gov (United States)

    Ferracin, P; Caspi, S; Felice, H; Leitner, D; Lyneis, C M; Prestemon, S; Sabbi, G L; Todd, D S

    2010-02-01

    Electron cyclotron resonance (ECR) ion sources are an essential component of heavy-ion accelerators. Over the past few decades advances in magnet technology and an improved understanding of the ECR ion source plasma physics have led to remarkable performance improvements of ECR ion sources. Currently third generation high field superconducting ECR ion sources operating at frequencies around 28 GHz are the state of the art ion injectors and several devices are either under commissioning or under design around the world. At the same time, the demand for increased intensities of highly charged heavy ions continues to grow, which makes the development of even higher performance ECR ion sources a necessity. To extend ECR ion sources to frequencies well above 28 GHz, new magnet technology will be needed in order to operate at higher field and force levels. The superconducting magnet program at LBNL has been developing high field superconducting magnets for particle accelerators based on Nb(3)Sn superconducting technology for several years. At the moment, Nb(3)Sn is the only practical conductor capable of operating at the 15 T field level in the relevant configurations. Recent design studies have been focused on the possibility of using Nb(3)Sn in the next generation of ECR ion sources. In the past, LBNL has worked on the VENUS ECR, a 28 GHz source with solenoids and a sextupole made with NbTi operating at fields of 6-7 T. VENUS has now been operating since 2004. We present in this paper the design of a Nb(3)Sn ECR ion source optimized to operate at an rf frequency of 56 GHz with conductor peak fields of 13-15 T. Because of the brittleness and strain sensitivity of Nb(3)Sn, particular care is required in the design of the magnet support structure, which must be capable of providing support to the coils without overstressing the conductor. In this paper, we present the main features of the support structure, featuring an external aluminum shell pretensioned with water

  10. Radio-Frequency (rf) Confinement in Ion Mobility Spectrometry: Apparent Mobilities and Effective Temperatures.

    Science.gov (United States)

    Allen, Samuel J; Bush, Matthew F

    2016-12-01

    Ion mobility is a powerful tool for separating and characterizing the structures of ions. Here, a radio-frequency (rf) confining drift cell is used to evaluate the drift times of ions over a broad range of drift field strengths (E/P, V cm(-1) Torr(-1)). The presence of rf potentials radially confines ions and results in excellent ion transmission at low E/P (less than 1 V cm(-1) Torr(-1)), thereby reducing the dependence of ion transmission on the applied drift voltage. Non-linear responses between drift time and reciprocal drift voltages are observed for extremely low E/P and high rf amplitudes. Under these conditions, pseudopotential wells generated by the rf potentials dampen the mobility of ions. The effective potential approximation is used to characterize this mobility dampening behavior, which can be mitigated by adjusting rf amplitudes and electrode dimensions. Using SIMION trajectories and statistical arguments, the effective temperatures of ions in an rf-confining drift cell are evaluated. Results for the doubly charged peptide GRGDS suggest that applied rf potentials can result in a subtle increase (2 K) in effective temperature compared to an electrostatic drift tube. Additionally, simulations of native-like ions of the protein complex avidin suggest that rf potentials have a negligible effect on the effective temperature of these ions. In general, the results of this study suggest that applied rf potentials enable the measurement of drift times at extremely low E/P and that these potentials have negligible effects on ion effective temperature. Graphical Abstract ᅟ.

  11. The development of the radio frequency driven negative ion source for neutral beam injectors (invited).

    Science.gov (United States)

    Kraus, W; Fantz, U; Franzen, P; Fröschle, M; Heinemann, B; Riedl, R; Wünderlich, D

    2012-02-01

    Large and powerful negative hydrogen ion sources are required for the neutral beam injection (NBI) systems of future fusion devices. Simplicity and maintenance-free operation favors RF sources, which are developed intensively at the Max-Planck-Institut für Plasmaphysik (IPP) since many years. The negative hydrogen ions are generated by caesium-enhanced surface conversion of atoms and positive ions on the plasma grid surface. With a small scale prototype the required high ion current density and the low fraction of co-extracted electrons at low pressure as well as stable pulses up to 1 h could be demonstrated. The modular design allows extension to large source dimensions. This has led to the decision to choose RF sources for the NBI of the international fusion reactor, ITER. As an intermediate step towards the full size ITER source at IPP, the development will be continued with a half-size source on the new ELISE testbed. This will enable to gain experience for the first time with negative hydrogen ion beams from RF sources of these dimensions.

  12. Status of the ion sources developments for the Spiral2 project at GANIL

    Energy Technology Data Exchange (ETDEWEB)

    Leherissier, P.; Bajeat, O.; Barue, C.; Canet, C.; Dubois, M.; Dupuis, M.; Flambard, J. L.; Frigot, R.; Jardin, P.; Leboucher, C.; Lemagnen, F.; Maunoury, L.; Osmond, B.; Pacquet, J. Y.; Pichard, A. [GANIL, Grand Accelerateur National d' Ions Lourds, CEA-DSM/CNRS-IN2P3, Bvd H. Becquerel, BP 55027 14076 Caen Cedex 5 (France); Thuillier, T. [LPSC, Universite Joseph Fourier Grenoble 1, CNRS/IN2P3, Institut Polytechnique de Grenoble, Grenoble (France); Peaucelle, C. [IPNL, Universite de Lyon, Universite de Lyon 1, CNRS/IN2P3, Villeurbanne (France)

    2012-02-15

    The SPIRAL 2 facility is now under construction and will deliver either stable or radioactive ion beams. First tests of nickel beam production have been performed at GANIL with a new version of the large capacity oven, and a calcium beam has been produced on the heavy ion low energy beam transport line of SPIRAL 2, installed at LPSC Grenoble. For the production of radioactive beams, several target/ion-source systems (TISSs) are under development at GANIL as the 2.45 GHz electron cyclotron resonance ion source, the surface ionization source, and the oven prototype for heating the uranium carbide target up to 2000 deg. C. The existing test bench has been upgraded for these developments and a new one, dedicated for the validation of the TISS before mounting in the production module, is under design. Results and current status of these activities are presented.

  13. The preliminary tests of the superconducting electron cyclotron resonance ion source DECRIS-SC2.

    Science.gov (United States)

    Efremov, A; Bekhterev, V; Bogomolov, S; Drobin, V; Loginov, V; Lebedev, A; Yazvitsky, N; Yakovlev, B

    2012-02-01

    A new compact version of the "liquid He-free" superconducting ECR ion source, to be used as an injector of highly charged heavy ions for the MC-400 cyclotron, is designed and built at the Flerov Laboratory of Nuclear Reactions in collaboration with the Laboratory of High Energy Physics of JINR. The axial magnetic field of the source is created by the superconducting magnet and the NdFeB hexapole is used for the radial plasma confinement. The microwave frequency of 14 GHz is used for ECR plasma heating. During the first tests, the source shows a good enough performance for the production of medium charge state ions. In this paper, we will present the design parameters and the preliminary results with gaseous ions.

  14. Nonlinear gyrokinetic simulations of ion-temperature-gradient turbulence for the optimized Wendelstein 7-X stellarator.

    Science.gov (United States)

    Xanthopoulos, P; Merz, F; Görler, T; Jenko, F

    2007-07-20

    Ion-temperature-gradient turbulence constitutes a possibly dominant transport mechanism for optimized stellarators, in view of the effective suppression of neoclassical losses characterizing these devices. Nonlinear gyrokinetic simulation results for the Wendelstein 7-X stellarator [G. Grieger, in (IAEA, Vienna, 1991) Vol. 3, p. 525]-assuming an adiabatic electron response-are presented. Several fundamental features are discussed, including the role of zonal flows for turbulence saturation, the resulting flux-gradient relationship, and the coexistence of ion-temperature-gradient modes with trapped ion modes in the saturated state.

  15. Effective versus ion thermal temperatures in the Weizmann Ne Z-pinch: Modeling and stagnation physics

    Energy Technology Data Exchange (ETDEWEB)

    Giuliani, J. L.; Thornhill, J. W.; Dasgupta, A.; Velikovich, A. L.; Chong, Y. K.; Mehlhorn, T. A. [Plasma Physics Division, Naval Research Laboratory, Washington, DC 20375 (United States); Kroupp, E.; Osin, D.; Maron, Y.; Starobinets, A.; Fisher, V.; Zarnitsky, Yu.; Bernshtam, V. [Weizmann Institute of Science, Rehovot 76100 (Israel); Apruzese, J. P. [Consultant to NRL through Engility Corp., Chantilly, Virginia 20151 (United States); Fisher, A. [Falculty of Physics, Technion-Israeli Institute of Technology, Haifa (Israel); Deeney, C. [National Security Technologies, LLC, Las Vegas, Nevada 89144 (United States)

    2014-03-15

    The difference between the ion thermal and effective temperatures is investigated through simulations of the Ne gas puff z-pinch reported by Kroupp et al. [Phys. Rev. Lett. 107, 105001 (2011)]. Calculations are performed using a 2D, radiation-magnetohydrodynamic code with Tabular Collisional-Radiative Equilibrium, namely Mach2-TCRE [Thornhill et al., Phys. Plasmas 8, 3480 (2001)]. The extensive data set of imaging and K-shell spectroscopy from the experiments provides a challenging validation test for z-pinch simulations. Synthetic visible images of the implosion phase match the observed large scale structure if the breakdown occurs at the density corresponding to the Paschen minimum. At the beginning of stagnation (−4 ns), computed plasma conditions change rapidly showing a rising electron density and a peak in the ion thermal temperature of ∼1.8 keV. This is larger than the ion thermal temperature (<400 eV) inferred from the experiment. By the time of peak K-shell power (0 ns), the calculated electron density is similar to the data and the electron and ion thermal temperatures are equilibrated, as is observed. Effective ion temperatures are obtained from calculated emission line widths accounting for thermal broadening and Doppler velocity shifts. The observed, large effective ion temperatures (∼4 keV) early in the stagnation of this Ne pinch can be explained solely as a combination of compressional ion heating and steep radial velocity gradients near the axis. Approximations in the modeling are discussed in regard to the higher ion thermal temperature and lower electron density early in the stagnation compared to the experimental results.

  16. Analytical study of effects of positron density and temperature anisotropy on electrostatic ion cyclotron instability

    Science.gov (United States)

    Barati Moqadam Niyat, M.; Khorashadizadeh, S. M.; Niknam, A. R.

    2017-03-01

    The effects of the positron concentration and ion temperature anisotropy on the electrostatic ion cyclotron instability are studied analytically, in a magnetized electron-positron-ion plasma with temperature anisotropy, using the linear kinetic theory. Positrons and electrons are supposed to drift either in the same direction or in opposite directions relative to singly ionized stationary ions and parallel to the magnetic field. The dispersion relation of the electrostatic ion cyclotron waves is derived, and then the conditions for exciting the instability of the waves are investigated. Moreover, the condition for the marginally stable state is also studied. It is found that as the positron concentration and perpendicular ion temperature increase, the growth rate of the electrostatic ion cyclotron instability decreases, whereas the critical drift velocity increases. It is also found that for the chosen set of parameters, with electrons and positrons drifting in the same direction, the instability in the plasma is stronger than when the electrons and positrons drift in opposite directions. In addition, a comparison is made to the normal electron-ion plasma.

  17. Quarkonia at finite temperature in relativistic heavy-ion collisions

    Indian Academy of Sciences (India)

    2015-05-06

    May 6, 2015 ... The connection between quarkonia and deconfinement began with the remarkable paper of Matsui and Satz [1]. The basic idea is extremely simple. At high temperatures, due to Debye screening, the binding between a ¯QQ pair takes the Yukawa form, and for sufficiently high temperatures, the ¯QQ meson ...

  18. Plasma diagnostics of the SIMPA Ecr ion source by X-ray spectroscopy, Collisions of H-like Neon ions with Argon clusters; Diagnostic du plasma de la source d'ions ECR SIMPA par spectroscopie X, Collision d'ions neon hydrogenoides avec des agregats d'argon

    Energy Technology Data Exchange (ETDEWEB)

    Adrouche, N

    2006-09-15

    The first part of this thesis is devoted to the SIMPA ECR ion source characterization, first, I explored the ion source's capacities on the point of view of extracted currents for three elements, argon, krypton and neon. By analyzing the Bremsstrahlung spectra, I determined the electronic temperature in the plasma and the electronic and ionic densities. In a second time, I recorded high resolution X-spectra of argon and krypton plasma's. By taking into account the principal mechanisms of production of a K hole in the ions inside the plasma, I determined the ionic densities of the high charge states of argon. Lastly, I highlighted a correlation between the ions charge states densities with the intensities of extracted currents. The second part of the thesis is devoted to Ne{sup 9+-} argon clusters collisions. First, I presented simple and effective theoretical models allowing to describe the phenomena occurring during a collision, from the point of view of the projectile. I carried out a simulation for a collision of an ion Ne{sup 9+} with an argon cluster of a given size, which has enabled us to know the energy levels populated during the electronic capture and to follow the number of electrons in each projectile shell. Lastly, I presented the first results of a collision between a Ne{sup 9+} beam and argon clusters. These results, have enabled me by using projectile X-ray spectroscopy during the ions-clusters collision, to evidence a strong clustering of targets atoms and to highlight an electronic multi-capture in the projectile ion excited states. (author)

  19. A multicharge ion source (Supernanogan) for the OLIS facility at ISAC/TRIUMF.

    Science.gov (United States)

    Jayamanna, K; Wight, G; Gallop, D; Dube, R; Jovicic, V; Laforge, C; Marchetto, M; Leross, M; Louie, D; Laplante, R; Laxdal, R; McDonald, M; Wiebe, G J; Wang, V; Yan, F

    2010-02-01

    The Off-Line Ion Source (OLIS) [K. Jayamanna, D. Yuan, T. Kuo, M. MacDonald, P. Schmor, and G. Dutto, Rev. Sci. Instrum. 67, 1061 (1996); K. Jayamanna, Rev. Sci. Instrum. 79, 02711 (2008)] facility consists of a high voltage terminal containing a microwave cusp ion source, either a surface ion source or a hybrid surface-arc discharge ion source [K. Jayamanna and C. Vockenhuber, Rev. Sci. Instrum. 79, 02C712 (2008)], and an electrostatic switch that allows the selection of any one of the sources without mechanical intervention. These sources provide a variety of +1 beams up to mass 30 for Isotope Separator and ACcelerator (ISAC) [R. E. Laxdal, Nucl. Instrum. Methods Phys. Res. B 204, 400 (2003)] experiments, commissioning the accelerators, setting up the radioactive experiments, and for tuning the beam lines. The radio frequency quadrupole (RFQ) [M. Marchetto, Z. T. Ang, K. Jayamanna, R. E. Laxdal, A. Mitra, and V. Zvyagintsev, Eur. Phys. J. Spec. Top. 150, 241 (2005)] injector accelerator is a constant velocity machine designed to accept only 2 keV/u and the source extraction energy is limited to 60 kV. Further stripping is then needed downstream of the RFQ to inject the beam into the drift tube linac [M. Marchetto, Z. T. Ang, K. Jayamanna, R. E. Laxdal, A. Mitra, and V. Zvyagintsev, Eur. Phys. J. Spec. Top. 150, 241 (2005)] accelerator that requires A/q up to 6. Base on this constraints a multicharge ion source capable to deliver beams above mass 30 with A/q up to 6 was needed in order to reach full capability of the ISAC facility. A Supernanogan [C. Bieth et al., Nucleonika 48, S93 (2003)] multicharge ion source was then purchased from Pantechnik and was installed in the OLIS terminal. Commissioning and performance of the Supernanogan with some results such as emittance dependence of the charge states as well as charge state efficiencies are presented.

  20. Effects of Solvent and Ion Source Pressure on the Analysis of Anabolic Steroids by Low Pressure Photoionization Mass Spectrometry

    Science.gov (United States)

    Liu, Chengyuan; Zhu, Yanan; Yang, Jiuzhong; Zhao, Wan; Lu, Deen; Pan, Yang

    2017-04-01

    Solvent and ion source pressure were two important factors relating to the photon induced ion-molecule reactions in low pressure photoionization (LPPI). In this work, four anabolic steroids were analyzed by LPPI mass spectrometry. Both the ion species present and their relative abundances could be controlled by switching the solvent and adjusting the ion source pressure. Whereas M•+, MH+, [M - H2O]+, and solvent adducts were observed in positive LPPI, [M - H]- and various oxidation products were abundant in negative LPPI. Changing the solvent greatly affected formation of the ion species in both positive and negative ion modes. The ion intensities of the solvent adduct and oxygen adduct were selectively enhanced when the ion source pressure was elevated from 68 to 800 Pa. The limit of detection could be decreased by increasing the ion source pressure.

  1. Codeposition of deuterium ions with beryllium oxide at elevated temperatures

    CERN Document Server

    Markin, A V; Gorodetsky, A E; Negodaev, M A; Rozhanskii, N V; Scaffidi-Argentina, F; Werle, H; Wu, C H; Zalavutdinov, R K; Zakharov, A P

    2000-01-01

    Deuterium-loaded BeO films were produced by sputtering the beryllium target with 10 keV Ne ions in D sub 2 gas at a pressure of approximately 1 Pa. The sputtered beryllium reacts - on the substrate surface - with the residual oxygen, thus forming a beryllium oxide layer. Biasing the substrate negatively with respect to the target provides the simultaneous bombardment of the growing film surface with D ions formed by Ne-D sub 2 collisions. Substrate potential governs the maximum energy of ions striking the growing film surface while its size governs the flux density. According to X-ray photoelectron spectroscopy (XPS), electron probe microanalysis (EPMA) and reflection high energy electron diffraction (RHEED) data, the beryllium is deposited in the form of polycrystalline hcp-BeO layers with negligible (about 1 at.%) carbon and neon retention. Thermal desorption spectroscopy (TDS) data shows a strong deuterium bonding, with a desorption peak at 950 K, in the films deposited at -50 and -400 V substrate potentia...

  2. Miniature High Stability High Temperature Space Rated Blackbody Radiance Source

    Science.gov (United States)

    Jones, J. A.; Beswick, A. G.

    1987-09-01

    This paper presents the design and test performance of a conical cavity type blackbody radiance source that will meet the requirements of the Halogen Occultation Experiment (HALOE) on the NASA Upper Atmospheric Research Satellite program (UARS). Since a radiance source meeting the requirements of this experiment was unavailable in the commercial market, a development effort was undertaken by the HALOE Project. The blackbody radiance source operates in vacuum at 1300 K + 0.5 K over any 15-minute interval, uses less than 7.5 watts of power, maintains a 49°C outer case temperature, and fits within the 2.5 x 2.5 x 3.0 inch envelope allocated inside the HALOE instrument. Also, the unit operates in air, during ground testing of the HALOE instrument, where it uses 17 watts of power with an outer case temperature of 66°C. The thrust of this design effort was to minimize the heat losses, in order to keep the power usage under 7.5 watts, and to minimize the amount of silica in the materials. Silica in the presence of the platinum heater winding used in this design would cause the platinum to erode, changing the operating temperature set-point. The design required the development of fabrication techniques which would provide very small, close tolerance parts from extremely difficult-to-machine materials. Also, a space rated ceramic core and unique, low thermal conductance, ceramic-to-metal joint was developed, tested and incorporated in this design. The completed flight qualification hardware has undergone performance, environmental and life testing. The design configuration and test results are discussed in detail in this paper.

  3. Final design of thermal diagnostic system in SPIDER ion source

    Energy Technology Data Exchange (ETDEWEB)

    Brombin, M., E-mail: matteo.brombin@igi.cnr.it; Dalla Palma, M.; Pasqualotto, R.; Pomaro, N. [Consorzio RFX, Corso Stati Uniti 4, I-35127 Padova (Italy)

    2016-11-15

    The prototype radio frequency source of the ITER heating neutral beams will be first tested in SPIDER test facility to optimize H{sup −} production, cesium dynamics, and overall plasma characteristics. Several diagnostics will allow to fully characterise the beam in terms of uniformity and divergence and the source, besides supporting a safe and controlled operation. In particular, thermal measurements will be used for beam monitoring and system protection. SPIDER will be instrumented with mineral insulated cable thermocouples, both on the grids, on other components of the beam source, and on the rear side of the beam dump water cooled elements. This paper deals with the final design and the technical specification of the thermal sensor diagnostic for SPIDER. In particular the layout of the diagnostic, together with the sensors distribution in the different components, the cables routing and the conditioning and acquisition cubicles are described.

  4. Final design of thermal diagnostic system in SPIDER ion source

    Science.gov (United States)

    Brombin, M.; Dalla Palma, M.; Pasqualotto, R.; Pomaro, N.

    2016-11-01

    The prototype radio frequency source of the ITER heating neutral beams will be first tested in SPIDER test facility to optimize H- production, cesium dynamics, and overall plasma characteristics. Several diagnostics will allow to fully characterise the beam in terms of uniformity and divergence and the source, besides supporting a safe and controlled operation. In particular, thermal measurements will be used for beam monitoring and system protection. SPIDER will be instrumented with mineral insulated cable thermocouples, both on the grids, on other components of the beam source, and on the rear side of the beam dump water cooled elements. This paper deals with the final design and the technical specification of the thermal sensor diagnostic for SPIDER. In particular the layout of the diagnostic, together with the sensors distribution in the different components, the cables routing and the conditioning and acquisition cubicles are described.

  5. Investigations on caesium-free alternatives for H- formation at ion source relevant parameters

    Science.gov (United States)

    Kurutz, U.; Fantz, U.

    2015-04-01

    Negative hydrogen ions are efficiently produced in ion sources by the application of caesium. Due to a thereby induced lowering of the work function of a converter surface a direct conversion of impinging hydrogen atoms and positive ions into negative ions is maintained. However, due to the complex caesium chemistry and dynamics a long-term behaviour is inherent for the application of caesium that affects the stability and reliability of negative ion sources. To overcome these drawbacks caesium-free alternatives for efficient negative ion formation are investigated at the flexible laboratory setup HOMER (HOMogenous Electron cyclotron Resonance plasma). By the usage of a meshed grid the tandem principle is applied allowing for investigations on material induced negative ion formation under plasma parameters relevant for ion source operation. The effect of different sample materials on the ratio of the negative ion density to the electron density nH- /ne is compared to the effect of a stainless steel reference sample and investigated by means of laser photodetachment in a pressure range from 0.3 to 3 Pa. For the stainless steel sample no surface induced effect on the negative ion density is present and the measured negative ion densities are resulting from pure volume formation and destruction processes. In a first step the dependency of nH- /ne on the sample distance has been investigated for a caesiated stainless steel sample. At a distance of 0.5 cm at 0.3 Pa the density ratio is 3 times enhanced compared to the reference sample confirming the surface production of negative ions. In contrast for the caesium-free material samples, tantalum and tungsten, the same dependency on pressure and distance nH- /ne like for the stainless steel reference sample were obtained within the error margins: A density ratio of around 14.5% is measured at 4.5 cm sample distance and 0.3 Pa, linearly decreasing with decreasing distance to 7% at 1.5 cm. Thus, tantalum and tungsten do not

  6. Ion temperatures in HIP-1 and SUMMA from charge-exchange neutral optical emission spectra

    Science.gov (United States)

    Patch, R. W.; Lauver, M. R.

    1976-01-01

    Ion temperatures were obtained from observations of the H sub alpha, D sub alpha, and He 587.6 nm lines emitted from hydrogen, deuterium, and helium plasmas in the SUMMA and HIP-1 mirror devices at Lewis Research Center. Steady state discharges were formed by applying a radially inward dc electric field between cylindrical or annular anodes and hollow cathodes located at the peaks of the mirrors. The ion temperatures were found from the Doppler broadening of the charge-exchange components of spectral lines. A statistical method was developed for obtaining scaling relations of ion temperature as a function of current, voltage, and magnetic flux density. Derivations are given that take into account triangular monochromator slit functions, loss cones, and superimposed charge-exchange processes. In addition, the Doppler broadening was found to be sensitive to the influence of drift on charge-exchange cross section. The effects of finite ion-cyclotron radius, cascading, and delayed emission are reviewed.

  7. Spectroscopic measurements of ion temperature in ATC Tokamak with RF and neutral beam heating

    Energy Technology Data Exchange (ETDEWEB)

    Suckewer, S.; Hinnov, E.

    1977-03-01

    Measurements of ion temperatures in the ATC Tokamak by means of Doppler broadening of various ion lines are described, and typical results presented for the various auxiliary heating experiments: compression, neutral beam, lower hybrid and ion cyclotron frequency heating. Radial resolution of the temperature measurements is achieved by utilizing spectrum lines of ions of different ionization potentials: OVII lambda 1623A, CV lambda 2271A and CIV lambda 1548A, which are emitted from regions of different electron temperature. Measurement at a given radial location is performed as a function of time by repeated scanning of the line contour in times 1.5 to 3.0 msec. The results indicate variations of heating efficiency with location and with power input level.

  8. Solid state generator for powerful radio frequency ion sources in neutral beam injection systems

    Energy Technology Data Exchange (ETDEWEB)

    Kraus, W.; Fantz, U.; Heinemann, B.; Franzen, P.

    2015-02-15

    Radio frequency ion sources used in neutral beam injection systems (NBI) of fusion machines are currently supplied by self-excited RF generators. These generators have both a low power efficiency and a limited frequency stability, therefore transistorized amplifiers are being considered for the power supply of the next generation of RF sources. A 75 kW generator, originally designed for broadcasting, has been tested with a negative ion source. High operational reliability and a very good matching to the plasma load has been demonstrated. These results make this generator type a very promising candidate for future NBI systems.

  9. Beam optics study of a negative ion source for neutral beam injection application at ASIPP

    Energy Technology Data Exchange (ETDEWEB)

    Wei, Jiang-Long; Liang, Li-Zhen [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); Jiang, Cai-Chao [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); Graduate school, University of Science and Technology of China, Hefei 230026 (China); Xie, Ya-Hong, E-mail: xieyh@ipp.ac.cn [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); Hu, Chun-Dong; Li, Jun; Gu, Yu-Ming; Chen, Yu-Qian [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); Li, Jing-Yong; Wu, Ming-Shan [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); Graduate school, University of Science and Technology of China, Hefei 230026 (China)

    2017-04-15

    In order to study the generation and extraction of negative ions for neutral beam injection application, a negative ion source is being designed and constructed at Institute of Plasma Physics, Chinese Academy of Sciences (ASIPP). Through a four electrode grids system inside the accelerator, a negative ion beam will be extracted and accelerated up to −60 kV on a reduced scale extraction area of 12 × 50 cm{sup 2} (the area of PG apertures is 185 cm{sup 2}). The beam optics is a key issue for the accelerator design, and greatly determine the source experimental performance in term of beam current, heat load on the grid, beam divergence, and so on. In this paper, the trajectories of electrons and negative ions were simulated in the electrode grids of the negative ion source. The filter capability of electron deflection magnet on the co-extracted electrons is evaluated and confirmed. The negative ion beam optics was designed according to the calculated results of beam divergence and beam radius along the beamlet in different acceleration voltages. The deflection effect of the electron deflection magnet on the negative ion beam was investigated in the single beamlet case and multi-beamlets case.

  10. Developments of fast emittance monitors for ion sources at RCNP

    Energy Technology Data Exchange (ETDEWEB)

    Yorita, T., E-mail: yorita@rcnp.osaka-u.ac.jp; Hatanaka, K.; Fukuda, M.; Shimada, K.; Yasuda, Y.; Saito, T.; Tamura, H.; Kamakura, K. [Research Center for Nuclear Physics (RCNP), Osaka University, Osaka 567-0047 (Japan)

    2016-02-15

    Recently, several developments of low energy beam transport line and its beam diagnostic systems have been performed to improve the injection efficiency of ion beam to azimuthally varying field cyclotron at Research Center for Nuclear Physics, Osaka University. One of those is the fast emittance monitor which can measure within several seconds for the efficient beam development and a Pepper-Pot Emittance Monitor (PPEM) has been developed. The PPEM consists of pepper-pot mask, multichannel plate, fluorescent screen, mirror, and CCD camera. The CCD image is taken via IEEE1394b to a personal computer and analyzed immediately and frequently, and then real time measurement with about 2 Hz has been achieved.

  11. Beam experiments with the Grenoble test electron cyclotron resonance ion source at iThemba LABS.

    Science.gov (United States)

    Thomae, R; Conradie, J; Fourie, D; Mira, J; Nemulodi, F; Kuechler, D; Toivanen, V

    2016-02-01

    At iThemba Laboratory for Accelerator Based Sciences (iThemba LABS) an electron cyclotron ion source was installed and commissioned. This source is a copy of the Grenoble Test Source (GTS) for the production of highly charged ions. The source is similar to the GTS-LHC at CERN and named GTS2. A collaboration between the Accelerators and Beam Physics Group of CERN and the Accelerator and Engineering Department of iThemba LABS was proposed in which the development of high intensity argon and xenon beams is envisaged. In this paper, we present beam experiments with the GTS2 at iThemba LABS, in which the results of continuous wave and afterglow operation of xenon ion beams with oxygen as supporting gases are presented.

  12. Beam experiments with the Grenoble test electron cyclotron resonance ion source at iThemba LABS

    Energy Technology Data Exchange (ETDEWEB)

    Thomae, R., E-mail: rthomae@tlabs.ac.za; Conradie, J.; Fourie, D.; Mira, J.; Nemulodi, F. [iThemba LABS, P.O. Box 722, Somerset West 7130 (South Africa); Kuechler, D.; Toivanen, V. [CERN, BE/ABP/HSL, 1211 Geneva 23 (Switzerland)

    2016-02-15

    At iThemba Laboratory for Accelerator Based Sciences (iThemba LABS) an electron cyclotron ion source was installed and commissioned. This source is a copy of the Grenoble Test Source (GTS) for the production of highly charged ions. The source is similar to the GTS-LHC at CERN and named GTS2. A collaboration between the Accelerators and Beam Physics Group of CERN and the Accelerator and Engineering Department of iThemba LABS was proposed in which the development of high intensity argon and xenon beams is envisaged. In this paper, we present beam experiments with the GTS2 at iThemba LABS, in which the results of continuous wave and afterglow operation of xenon ion beams with oxygen as supporting gases are presented.

  13. Influence of grid control on beam quality in laser ion source generating high-current low-charged copper ions

    Energy Technology Data Exchange (ETDEWEB)

    Hasegawa, J.; Yoshida, M.; Ogawa, M.; Oguri, Y.; Nakajima, M.; Horioka, K.; Kwan, J.

    2003-08-01

    We examined grid-controlled extraction for a laser ion source using a KrF laser. By using grid-controlled extraction in the over-dense regime, we found that the ion beam current waveforms were stabilized more significantly as the grid bias raised from -90 V to -280 V. The normalized emittance of 0.08 {pi}mm-mrad measured without the grid control was improved to 0.06 {pi}mm-mrad with the grid control. In contrast to this observation, the grid bias disturbed the pattern of the beam extracted in the source-limited regime. Fast extraction was carried out using a high-voltage pulse with a rise time of {approx} 100 ns. The grid control suppressed successfully the beam pedestal originating from the plasma pre-filled in the extraction gap.

  14. A Novel Microwave-Induced Plasma Ionization Source for Ion Mobility Spectrometry

    Science.gov (United States)

    Dai, Jianxiong; Zhao, Zhongjun; Liang, Gaoling; Duan, Yixiang

    2017-03-01

    This work demonstrates the application of a novel microwave induced plasma ionization (MIPI) source to ion mobility spectrometry (IMS). The MIPI source, called Surfatron, is composed of a copper cavity and a hollow quartz discharge tube. The ion mobility spectrum of synthetics air has a main peak with reduced mobility of 2.14 cm2V-1s-1 for positive ion mode and 2.29 cm2V-1s-1 for negative ion mode. The relative standard deviations (RSD) are 0.7% and 1.2% for positive and negative ion mode, respectively. The total ion current measured was more than 3.5 nA, which is much higher than that of the conventional 63Ni source. This indicates that a better signal-to-noise ratio (SNR) can be acquired from the MIPI source. The SNR was 110 in the analysis of 500 pptv methyl tert-butyl ether (MTBE), resulting in the limit of detection (SNR = 3) of 14 pptv. The linear range covers close to 2.5 orders of magnitude in the detection of triethylamine with a concentration range from 500 pptv to 80 ppbv. Finally, this new MIPI-IMS was used to detect some volatile organic compounds, which demonstrated that the MIPI-IMS has great potential in monitoring pollutants in air.

  15. Experimental study of high current negative ion sources D{sup -} / H{sup -}. Analysis based on the simulation of the negative ion transport in the plasma source; Etude experimentale de sources a fort courant d`ions negatifs D{sup -} / H{sup -}. Analyse fondee sur la simulation du transport des ions dans le plasma de la source

    Energy Technology Data Exchange (ETDEWEB)

    Riz, D.

    1996-10-30

    In the frame of the development of a neutral beam injection system able to work the ITER tokamak (International Thermonuclear Experimental Reactor), two negative ion sources, Dragon and Kamaboko, have been installed on the MANTIS test bed in Cadarache, and studies in order to extract 20 mA/cm{sup 2} of D{sup -}. The two production modes of negative ions have been investigated: volume production; surface production after cesium injection in the discharge. Experiments have shown that cesium seeding is necessary in order to reach the requested performances for ITER. 20 mA/cm{sup 2} have been extracted from the Kamaboko source for an arc power density of 2.5 kW/liter. Simultaneously, a code called NIETZSCHE has been developed to simulate the negative ions transport in the source plasma, from their birth place to the extraction holes. The ion trajectory is calculated by numerically solving the 3D motion equation, while the atomic processes of destruction, of elastic collisions H{sup -}/H{sup +} and of charge exchange H{sup -}/H{sup 0} are handled at each time step by a Monte Carlo procedure. The code allows to obtain the extraction probability of a negative ion produced at a given location. The calculations performed with NIETZSCHE have allowed to explain several phenomena observed on negative ion sources, such as the isotopic effect H{sup -}/D{sup -} and the influence of the polarisation of the plasma grid and of the magnetic filter on the negative ions current. The code has also shown that, in the type of sources contemplated for ITER, working with large arc power densities (> 1 kW/liter), only negative ions produced in volume at a distance lower that 2 cm from the plasma grid and those produced at the grid surface have a chance of being extracted. (author). 122 refs.

  16. Influence of transversal magnetic field on negative ion extraction process in 3D computer simulation of the multi-aperture ion source

    Science.gov (United States)

    Turek, M.; Sielanko, J.; Franzen, P.; Speth, E.

    2006-01-01

    The negative ion beam extraction from the multi-hole ion source is considered. Results of numerical simulations (based on PIC method) of the influence of transversal magnetic field aplied near the extraction grid (filter field), and in the plasma chamber volume (confining field) are presented. The application of confinig field results in significantly increased negative ions yield.

  17. Spectroscopic measurement of ion temperature and ion velocity distributions in the flux-coil generated FRC.

    Science.gov (United States)

    Gupta, D; Bolte, N; Gota, H; Hayashi, R; Kiyashko, V; Marsili, P; Morehouse, M; Primavera, S; Roche, T; Wessel, F

    2010-10-01

    One aim of the flux-coil generated field reversed configuration at Tri Alpha Energy (TAE) is to establish the plasma where the ion rotational energy is greater than the ion thermal energy. To verify this, an optical diagnostic was developed to simultaneously measure the Doppler velocity-shift and line-broadening using a 0.75 m, 1800 groves/mm, spectrometer. The output spectrum is magnified and imaged onto a 16-channel photomultiplier tube (PMT) array. The individual PMT outputs are coupled to high-gain, high-frequency, transimpedance amplifiers, providing fast-time response. The Doppler spectroscopy measurements, along with a survey spectrometer and photodiode-light detector, form a suite of diagnostics that provide insights into the time evolution of the plasma-ion distribution and current when accelerated by an azimuthal-electric field.

  18. Spectroscopic measurement of ion temperature and ion velocity distributions in the flux-coil generated FRC

    Energy Technology Data Exchange (ETDEWEB)

    Gupta, D.; Gota, H.; Hayashi, R.; Kiyashko, V.; Morehouse, M.; Primavera, S. [Tri Alpha Energy, Inc., Rancho Santa Margarita, California 92688 (United States); Bolte, N. [Tri Alpha Energy, Inc., Rancho Santa Margarita, California 92688 (United States); Department of Physics and Astronomy, University of California, Irvine, California 92697 (United States); Marsili, P. [Department of Physics, University of Pisa, Largo B. Pontecorvo 3, 56127 Pisa (Italy); Roche, T. [Department of Physics and Astronomy, University of California, Irvine, California 92697 (United States); Wessel, F. [Department of Physics and Astronomy, University of California, Irvine, California 92697 (United States); Tri Alpha Energy, Inc., Rancho Santa Margarita, California 92688 (United States)

    2010-10-15

    One aim of the flux-coil generated field reversed configuration at Tri Alpha Energy (TAE) is to establish the plasma where the ion rotational energy is greater than the ion thermal energy. To verify this, an optical diagnostic was developed to simultaneously measure the Doppler velocity-shift and line-broadening using a 0.75 m, 1800 groves/mm, spectrometer. The output spectrum is magnified and imaged onto a 16-channel photomultiplier tube (PMT) array. The individual PMT outputs are coupled to high-gain, high-frequency, transimpedance amplifiers, providing fast-time response. The Doppler spectroscopy measurements, along with a survey spectrometer and photodiode-light detector, form a suite of diagnostics that provide insights into the time evolution of the plasma-ion distribution and current when accelerated by an azimuthal-electric field.

  19. Progress in the development of a large RF negative ion source for fusion

    Energy Technology Data Exchange (ETDEWEB)

    Vollmer, O. E-mail: otv@ipp.mpg.de; Heinemann, B.; Kraus, W.; McNeely, P.; Riedl, R.; Speth, E.; Trainham, R.; Wilhelm, R

    2001-10-01

    A large area RF source for negative ion-based injection systems has been developed and for the first time H{sup -}-current densities have been extracted which are comparable to those produced by conventional arc sources. This paper describes the design of the source and gives the results of H{sup -}-extraction experiments. A feature of this RF source is an increase of extracted ion current by up to a factor of four if noble gases are added to the hydrogen discharge. By this effect, a current density of 9 mA/cm{sup 2} at 0.65 Pa has been achieved in volume production. With caesium seeding up to 20 mA/cm{sup 2} could be extracted at 1 Pa source pressure with the addition of argon and a hot plasma grid. Recently, the RF source has been modified for long pulse operation by the installation of a Faraday screen.

  20. A possibility of local measurements of ion temperature in a high-temperature plasma by laser induced ionization

    NARCIS (Netherlands)

    Kantor, M.

    2012-01-01

    A new diagnostic for local measurements of ion temperature and drift velocity in fusion plasmas is proposed in the paper. The diagnostic is based on laser induced ionization of excited hydrogen and deuterium atoms from the levels which ionization energy less than the laser photon energy. A high

  1. Existence domain of the compressive ion acoustic super solitary wave in a two electron temperature warm multi-ion plasma

    Science.gov (United States)

    Steffy, S. V.; Ghosh, S. S.

    2017-10-01

    The transition of an ion acoustic solitary wave into a "supersoliton," or a super solitary wave have been explored in a two electron temperature warm multi-ion plasma using the Sagdeev pseudopotential technique. It is generally believed that the ion acoustic solitary wave can be transformed to a super solitary wave only through a double layer. The present work shows that the transition route of an ion acoustic solitary wave to a super solitary wave is not unique. Depending on the electron temperature ratio, a regular solitary wave may transform to a super solitary wave either via the double layer, or through an extra-nonlinear solitary structure whose morphology differs from that of a regular one. These extra-nonlinear structures are associated with a fluctuation of the charge separation within the potential profile and are named as "variable solitary waves." Depending on these analyses, the upper and lower bounds of a super solitary wave have been deciphered and its existence domain has been delineated in the parametric space. It reveals that super solitary waves are a subset of a more generalized class of extra-nonlinear solitary structures called variable solitary waves.

  2. First results of the 2.45 GHz Oshima electron cyclotron resonance ion source

    Energy Technology Data Exchange (ETDEWEB)

    Asaji, T., E-mail: asaji@nc-toyama.ac.jp [National Institute of Technology, Toyama College, 13 Hongo, Toyama 939-8630 (Japan); Nakamura, T.; Furuse, M. [National Institute of Technology, Oshima College, 1091-1 Komatsu, Suouoshima, Oshima, Yamaguchi 742-2193 (Japan); Hitobo, T. [Tateyama Machine Co., Ltd., 30 Shimonoban, Toyama 930-1305 (Japan); Uchida, T. [Graduate School of Engineering, Toyo University, 2100 Kujirai, Kawagoe, Saitama 350-8585 (Japan); Muramatsu, M. [National Institute of Radiological Sciences (NIRS), 4-9-1 Anagawa, Inage-ku, Chiba 263-8555 (Japan); Kato, Y. [Graduate School of Engineering, Osaka University, 2-1 Yamada-oka, Suita, Osaka 565-0871 (Japan)

    2016-02-15

    A new electron cyclotron resonance ion source has been constructed at Oshima College with a 2.45 GHz magnetron microwave source and permanent magnets employed as the main components. In addition, a solid-state power amplifier with a frequency range of 2.5–6.0 GHz was installed to study two-frequency plasma heating. Three solenoid coils were set up for adjusting the axial magnetic fields. Argon plasma generation and ion beam production have been conducted during the first year of operation. Ion current densities in the ECR plasma were measured using a biased disk. For 2.45 and 4.65 GHz two-frequency plasma heating, the ion density was approximately 1.5 times higher than that of 2.45 GHz single-frequency heating.

  3. $CO_{2}$ laser ion source Comparison between mode-locked and free- running laser beams

    CERN Document Server

    Lisi, N; Scrivens, R

    2001-01-01

    The production of highly charged ions in a CO/sub 2/ laser-generated plasma is compared for different laser pulse-time structures. The work was performed at the CERN Laser Ion Source, which has the aim of developing a high current, high charge-state ion source for the Large Hadron Collider (LHC). When an intense laser pulse is focused onto a high-Z metal target, the ions expanding in the plasma plume are suitable for extraction from the plasma and matching into a synchrotron. For the first time, a comparison is made between free- running pulses with randomly fluctuating intensity, and mode-locked pulse trains with a reproducible structure and the same energy. Despite the lower power density with respect to the mode-locked pulse train, the free-running pulse provides higher charge states and higher yield. (10 refs).

  4. Negative ion production in the RF multiaperture surface-plasma source

    Energy Technology Data Exchange (ETDEWEB)

    Abdrashitov, G.; Belchenko, Yu., E-mail: Belchenko@inp.nsk.su; Dranichnikov, A.; Gorbovsky, A.; Kapitonov, V.; Kolmogorov, V.; Kondakov, A.; Konstantinov, S.; Sanin, A.; Selivanov, A.; Selivanov, P.; Shikhovtsev, I.; Stupishin, N.; Tiunov, M. [Budker Institute of Nuclear Physics, Novosibirsk (Russian Federation); Ivanov, A.; Sotnikov, O. [Budker Institute of Nuclear Physics, Novosibirsk (Russian Federation); Novosibirsk State University, Novosibirsk (Russian Federation); Binderbauer, M.; Putvinski, S.; Smirnov, A.; Sevier, L. [Tri Alpha Energy Inc., Rancho Santa Margarita, CA 92688 (United States)

    2015-04-08

    The experiments on negative hydrogen ion beam production in a multi-aperture long-pulse surface-plasma source are described. H- ions are produced on the surface of a plasma grid covered by cesium and illuminated by fast plasma particles. The source uses a radio-frequency driver to generate plasma. A composite magnet system made of external permanent magnets confines and filters electrons in the plasma region, and deflects them in the extraction area. A multiaperture, multi-electrode ion optical system is used for beam formation. The electrode heating and cooling during long pulses is accomplished by circulating a heat transfer fluid through channels drilled in the electrodes bodies. H- ions extraction through a single aperture and 21 apertures was performed and studied. A stable H- beam with the current up to 0.7 A, energy up to 74 kV, and pulse duration up to 7 s was routinely obtained.

  5. Removal of singularity in radial Langmuir probe models for non-zero ion temperature

    Science.gov (United States)

    Regodón, Guillermo Fernando; Fernández Palop, José Ignacio; Tejero-del-Caz, Antonio; Díaz-Cabrera, Juan Manuel; Carmona-Cabezas, Rafael; Ballesteros, Jerónimo

    2017-10-01

    We solve a radial theoretical model that describes the ion sheath around a cylindrical Langmuir probe with finite non-zero ion temperature in which singularity in an a priori unknown point prevents direct integration. The singularity appears naturally in fluid models when the velocity of the ions reaches the local ion speed of sound. The solutions are smooth and continuous and are valid from the plasma to the probe with no need for asymptotic matching. The solutions that we present are valid for any value of the positive ion to electron temperature ratio and for any constant polytropic coefficient. The model is numerically solved to obtain the electric potential and the ion population density profiles for any given positive ion current collected by the probe. The ion-current to probe-voltage characteristic curves and the Sonin plot are calculated in order to use the results of the model in plasma diagnosis. The proposed methodology is adaptable to other geometries and in the presence of other presheath mechanisms.

  6. Proton transfer and complex formation of angiotensin I ions with gaseous molecules at various temperature

    Energy Technology Data Exchange (ETDEWEB)

    Nonose, Shinji, E-mail: nonose@yokohama-cu.ac.jp; Yamashita, Kazuki; Sudo, Ayako; Kawashima, Minami

    2013-09-23

    Highlights: • Proton transfer from angiotensin I ions (z = 2, 3) to gaseous molecules was studied. • Temperature dependence of absolute reaction rate constants was measured. • Remarkable changes were obtained for distribution of product ions and reaction rate constants. • Proton transfer reaction was enhanced and reduced by complex formation. • Conformation changes are induced by complex formation and or by thermal collision with He. - Abstract: Proton transfer reactions of angiotensin I ions for +2 charge state, [M + 2H]{sup 2+}, to primary, secondary and aromatic amines were examined in the gas phase. Absolute reaction rate constants for proton transfer were determined from intensities of parent and product ions in the mass spectra. Temperature dependence of the reaction rate constants was measured. Remarkable change was observed for distribution of product ions and reaction rate constants. Proton transfer reaction was enhanced or reduced by complex formation of [M + 2H]{sup 2+} with gaseous molecules. The results relate to conformation changes of [M + 2H]{sup 2+} with change of temperature, which are induced by complex formation and or by thermal collision with He. Proton transfer reactions of angiotensin I ions for +3 charge state, [M + 3H]{sup 3+}, were also studied. The reaction rates did not depend on temperature so definitely.

  7. Effects of ion-fluid temperature on dust-ion-acoustic solitons

    Indian Academy of Sciences (India)

    tures (width and amplitude) of DIA solitons, but also introduces some new features of. DIA solitons. Keywords. Dusty plasmas; dust-ion-acoustic solitons; reductive perturbation method. PACS Nos 52.27.Lw; 52.35.Mw; 52.35.Sb. 1. Introduction. Shukla and Silin [1] have first theoretically shown that due to the conservation of.

  8. Performance and operation of advanced superconducting electron cyclotron resonance ion source SECRAL at 24 GHz.

    Science.gov (United States)

    Zhao, H W; Lu, W; Zhang, X Z; Feng, Y C; Guo, J W; Cao, Y; Li, J Y; Guo, X H; Sha, S; Sun, L T; Xie, D Z

    2012-02-01

    SECRAL (superconducting ECR ion source with advanced design in Lanzhou) ion source has been in routine operation for Heavy Ion Research Facility in Lanzhou (HIRFL) accelerator complex since May 2007. To further enhance the SECRAL performance in order to satisfy the increasing demand for intensive highly charged ion beams, 3-5 kW high power 24 GHz single frequency and 24 GHz +18 GHz double frequency with an aluminum plasma chamber were tested, and some exciting results were produced with quite a few new record highly charged ion beam intensities, such as (129)Xe(35+) of 64 eμA, (129)Xe(42+) of 3 eμA, (209)Bi(41+) of 50 eμA, (209)Bi(50+) of 4.3 eμA and (209)Bi(54+) of 0.2 eμA. In most cases SECRAL is operated at 18 GHz to deliver highly charged heavy ion beams for the HIRFL accelerator, only for those very high charge states and very heavy ion beams such as (209)Bi(36+) and (209)Bi(41+), SECRAL has been operated at 24 GHz. The total operation beam time provided by SECRAL up to July 2011 has exceeded 7720 hours. In this paper, the latest performance, development, and operation status of SECRAL ion source are presented. The latest results and reliable long-term operation for the HIRFL accelerator have demonstrated that SECRAL performance for production of highly charged heavy ion beams remains improving at higher RF power with optimized tuning.

  9. Portable test bench for the studies concerning ion sources and ion beam extraction and focusing systems; Banco de pruebas portatil para el estudio de fuentes de iones y de la extraccion y enfoque del haz de iones

    Energy Technology Data Exchange (ETDEWEB)

    Cordero Lopez, F.

    1961-07-01

    A portable test bench is described, which was designed to check ion sources, ion beam extraction and focusing systems before its use in a 600 KeV Cockcroft-Walton accelerator. The vacuum possibilities of the system are specially analyzed in connection with its particular use. The whole can be considered as a portable accelerator of low energy (50 keV). (Author)

  10. Discharge Characteristics of Large-Area High-Power RF Ion Source for Positive and Negative Neutral Beam Injectors

    Science.gov (United States)

    Chang, Doo-Hee; Jeong, Seung Ho; Park, Min; Kim, Tae-Seong; Jung, Bong-Ki; Lee, Kwang Won; In, Sang Ryul

    2016-12-01

    A large-area high-power radio-frequency (RF) driven ion source was developed for positive and negative neutral beam injectors at the Korea Atomic Energy Research Institute (KAERI). The RF ion source consists of a driver region, including a helical antenna and a discharge chamber, and an expansion region. RF power can be transferred at up to 10 kW with a fixed frequency of 2 MHz through an optimized RF matching system. An actively water-cooled Faraday shield is located inside the driver region of the ion source for the stable and steady-state operations of high-power RF discharge. Plasma ignition of the ion source is initiated by the injection of argon-gas without a starter-filament heating, and the argon-gas is then slowly exchanged by the injection of hydrogen-gas to produce pure hydrogen plasmas. The uniformities of the plasma parameter, such as a plasma density and an electron temperature, are measured at the lowest area of the driver region using two RF-compensated electrostatic probes along the direction of the short-and long-dimensions of the driver region. The plasma parameters will be compared with those obtained at the lowest area of the expansion bucket to analyze the plasma expansion properties from the driver region to the expansion region. supported by the Ministry of Science, ICT and Future Planning of the Republic of Korea under the ITER Technology R&D Program, and National R&D Program Through the National Research Foundation of Korea (NRF) Funded by the Ministry of Science, ICT & Future Planning (NRF-2014M1A7A1A03045372)

  11. A dynamic analysis of the magnetized plasma sheath in a collisionless scenario with ion sources

    Science.gov (United States)

    Adhikari, S.; Moulick, R.; Goswami, K. S.

    2017-08-01

    The influence of the forces that control the ion dynamics inside a magnetized plasma sheath under collisionless conditions is analyzed. Considering the ionization, the effects of the variation of field strength and the inclination angle on the force fields inside the sheath are studied. The pitch length and pitch angle for the particle velocity fields are also calculated and have been found to vary widely with the inclination angle and the strength of the magnetic field. The role of the Lorentz force and energy acquired by the ions while moving towards the wall is highlighted. A comparison between two different ion sources has also been foregrounded.

  12. Modeling and design of a beam emission spectroscopy diagnostic for the negative ion source NIO1.

    Science.gov (United States)

    Barbisan, M; Zaniol, B; Cavenago, M; Pasqualotto, R

    2014-02-01

    Consorzio RFX and INFN-LNL are building a flexible small ion source (Negative Ion Optimization 1, NIO1) capable of producing about 130 mA of H(-) ions accelerated at 60 KeV. Aim of the experiment is to test and develop the instrumentation for SPIDER and MITICA, the prototypes, respectively, of the negative ion sources and of the whole neutral beam injectors which will operate in the ITER experiment. As SPIDER and MITICA, NIO1 will be monitored with beam emission spectroscopy (BES), a non-invasive diagnostic based on the analysis of the spectrum of the Hα emission produced by the interaction of the energetic ions with the background gas. Aim of BES is to monitor direction, divergence, and uniformity of the ion beam. The precision of these measurements depends on a number of factors related to the physics of production and acceleration of the negative ions, to the geometry of the beam, and to the collection optics. These elements were considered in a set of codes developed to identify the configuration of the diagnostic which minimizes the measurement errors. The model was already used to design the BES diagnostic for SPIDER and MITICA. The paper presents the model and describes its application to design the BES diagnostic in NIO1.

  13. Status report of the 28 GHz superconducting electron cyclotronresonance ion source VENUS

    Energy Technology Data Exchange (ETDEWEB)

    Leitner, Daniela; Lyneis, Claude M.; Loew, Timothy; Todd, D.S.; Virostek, S.; Tarvainen, O.

    2005-09-01

    The superconducting versatile electron cyclotron resonance ECR ion source for nuclear science (VENUS) is a next generation superconducting ECR ion source designed to produce high-current, high-charge-state ions for the 88-Inch Cyclotron at the Lawrence Berkeley National Laboratory. VENUS also serves as the prototype ion source for the rare isotope accelerator RIA front end, where the goal is to produce intense beams of medium-charge-state ions. Example beams for the RIA accelerator are 15 p mu A of Kr17+ (260 e mu A), 12 p mu A of Xe20+ (240e mu A), and 8 p mu A of U28+ (230 e mu A). To achieve these high currents, VENUS has been optimized for operation at 28 GHz, reaching maximal confinement fields of 4 and 3 T axially and over 2.2 T on the plasma chamber wall radially. After a commissioning phase at 18 GHz, the source started the 28 GHz operation in the summer of 2004. During that ongoing 28 GHz commissioning process, record ion-beam intensities have been extracted. For instance, measured extracted currents for the low to medium charge states were 270 e mu A of Xe27+ and 245 e mu A of Bi29+, while for the higher charge states 15 e mu A of Xe34+, 15 e mu A of Bi41+, and 0.5 e mu A of Bi50+ could be produced. Results from the ongoing 28 GHz commissioning as well as results using double-frequency heating with 18 and 28 GHz for oxygen and xenon are presented. The effect of the minimum B field on the ion source performance has been systematically measured for 18 and 28 GHz. In both cases the performance peaked at a minimum B field of about 80 percent of the resonance field. In addition, a strong dependence of the x-ray flux and energy on the minimum B field value was found.

  14. First results from the new RIKEN superconducting electron cyclotron resonance ion source (invited).

    Science.gov (United States)

    Nakagawa, T; Higurashi, Y; Ohnishi, J; Aihara, T; Tamura, M; Uchiyama, A; Okuno, H; Kusaka, K; Kidera, M; Ikezawa, E; Fujimaki, M; Sato, Y; Watanabe, Y; Komiyama, M; Kase, M; Goto, A; Kamigaito, O; Yano, Y

    2010-02-01

    The next generation heavy ion accelerator facility, such as the RIKEN radio isotope (RI) beam factory, requires an intense beam of high charged heavy ions. In the past decade, performance of the electron cyclotron resonance (ECR) ion sources has been dramatically improved with increasing the magnetic field and rf frequency to enhance the density and confinement time of plasma. Furthermore, the effects of the key parameters (magnetic field configuration, gas pressure, etc.) on the ECR plasma have been revealed. Such basic studies give us how to optimize the ion source structure. Based on these studies and modern superconducting (SC) technology, we successfully constructed the new 28 GHz SC-ECRIS, which has a flexible magnetic field configuration to enlarge the ECR zone and to optimize the field gradient at ECR point. Using it, we investigated the effect of ECR zone size, magnetic field configuration, and biased disk on the beam intensity of the highly charged heavy ions with 18 GHz microwaves. In this article, we present the structure of the ion source and first experimental results with 18 GHz microwave in detail.

  15. Temperature Activated Diffusion of Radicals through Ion Implanted Polymers

    DEFF Research Database (Denmark)

    Wakelin, Edgar A.; Davies, Michael J.; Bilek, Marcela M. M.

    2015-01-01

    and controlling the diffusion of radicals through this layer will enable efficient optimization of this technique. We develop a model based on site to site diffusion according to Fick's second law with temperature activation according to the Arrhenius relation. Using our model, the Arrhenius exponential prefactor...

  16. Temperature Dependence of the Stability of Ion Pair Interactions ...

    Indian Academy of Sciences (India)

    Abstract. An understanding of the determinants of the thermal stability of thermostable proteins is expected to enable design of enzymes that can be employed in industrial biocatalytic processes carried out at high temperatures. A major factor that has been proposed to stabilize thermostable proteins is the high occurrence.

  17. Temperature Dependence of the Stability of Ion Pair Interactions ...

    Indian Academy of Sciences (India)

    An understanding of the determinants of the thermal stability of thermostable proteins is expected to enable design of enzymes that can be employed in industrial biocatalytic processes carried out at high temperatures. A major factor that has been proposed to stabilize thermostable proteins is the high occurrenceof salt ...

  18. Elements and inorganic ions as source tracers in recent Greenland snow

    Science.gov (United States)

    Lai, Alexandra M.; Shafer, Martin M.; Dibb, Jack E.; Polashenski, Chris M.; Schauer, James J.

    2017-09-01

    Atmospheric transport of aerosols leads to deposition of impurities in snow, even in areas of the Arctic as remote as Greenland. Major ions (e.g. Na+, Ca2+, NH4+, K+, SO42-) are frequently used as tracers for common aerosol sources (e.g. sea spray, dust, biomass burning, anthropogenic emissions). Trace element data can supplement tracer ion data by providing additional information about sources. Although many studies have considered either trace elements or major ions, few have reported both. This study determined total and water-soluble concentrations of 31 elements (Al, As, Ca, Cd, Ce, Co, Cr, Dy, Eu, Fe, Gd, K, La, Mg, Mn, Na, Nb, Nd, Pb, Pr, S, Sb, Si, Sm, Sn, Sr, Ti, V, U, Y, Zn) in shallow snow pits at 22 sampling sites in Greenland, along a transect from Summit Station to sites in the northwest. Black carbon (BC) and inorganic ions were measured in colocated samples. Sodium, which is typically used as a tracer of sea spray, did not appear to have any non-marine sources. The rare earth elements, alkaline earth elements (Mg, Ca, Sr), and other crustal elements (Fe, Si, Ti, V) were not enriched above crustal abundances relative to Al, indicating that these elements are primarily dust sourced. Calculated ratios of non-sea salt Ca (nssCa) to estimated dust mass affirm the use of nssCa as a dust tracer, but suggest up to 50% uncertainty in that estimate in the absence of other crustal element data. Crustal enrichment factors indicated that As, Cd, Pb, non-sea-salt S, Sb, Sn, and Zn were enriched in these samples, likely by anthropogenic sources. Principal component analysis indicated more than one crustal factor, and a variety of factors related to anthropogenically enriched elements. Analysis of trace elements alongside major tracer ions does not change interpretation of ion-based source attribution for sources that are well-characterized by ions, but is valuable for assessing uncertainty in source attribution and identifying sources not represented by major ions.

  19. Performance of the modified DREAMS ion source for {sup 36}Cl applications

    Energy Technology Data Exchange (ETDEWEB)

    Pavetich, Stefan; Akhmadaliev, Shavkat; Merchel, Silke; Rugel, Georg; Ziegenruecker, Rene [Helmholtz-Zentrum Dresden-Rossendorf (Germany)

    2014-07-01

    First analyses of real {sup 36}Cl-AMS samples were performed with the newly developed low memory-effect ion source at the DREsden Accelerator Mass Spectrometry (DREAMS) facility. Considerable improvements have been reached with respect to the overall ion source performance. Especially, parameters like current output, ion source fractionation effects, normalization factors, blank values and sulphur suppression factors have been investigated to enhance accuracy of {sup 36}Cl-data. Applications cover a wide spectrum, which implies also highly variable {sup 36}Cl/{sup 35+37}Cl-ratios ranging from nearly background level of ∝10{sup -15} up to 10{sup -10}. Samples from aquifers in arid regions for groundwater dating and modelling were analysed. Meteorite samples were measured to investigate the constancy of the galactic cosmic radiation, production rates from sulphur, and reconstruction of exposure histories of individual meteorites.

  20. Recent developments of target and ion sources to produce ISOL beams

    Science.gov (United States)

    Stora, T.

    2013-12-01

    In this review on target and ion sources for ISOL (Isotope Separation OnLine) beams, important developments from the past five years are highlighted. While at precedent EMIS conferences, a particular focus was given to a single topics, for instance specifically on ion sources or on chemical purification techniques, here each of the important elements present in an ISOL production unit is discussed. Fast diffusing nanomaterials, uranium-based targets, high power targets for next generation facilities, purification by selective adsorption, new ion sources are all part of this review. For each of these selected topics, the reported results lead to significant gains in intensity, purity, or quality of the delivered beam, or in the production of new isotope beams. Often the outcome resulted from the combination of original ideas with state-of-the-art investigations; this was carried out using very different scientific disciplines, leading to understanding of the underlying chemical or physical mechanisms at the origin of the improvements.

  1. Recent developments of target and ion sources to produce ISOL beams

    CERN Document Server

    Stora, Thierry

    2013-01-01

    In this review on target and ion sources for ISOL (Isotope Separation OnLine) beams, important develop- ments from the past five years are highlighted. While at precedent EMIS conferences, a particular focus was given to a single topics, for instance specifically on ion sources or on chemical purification tech- niques, here each of the important elements present in an ISOL production unit is discussed. Fast diffus- ing nanomaterials, uranium-based targets, high power targets for next generation facilities, purification by selective adsorption, new ion sources are all part of this review. For each of these selected topics, the reported results lead to significant gains in intensity, purity, or quality of the delivered beam, or in the production of new isotope beams. Often the outcome resulted from the combination of original ideas with state-of-the-art investigations; this was carried out using very different scientific disciplines, lead- ing to understanding of the underlying chemical or physical mechanisms a...

  2. STABILITY OF BETACYANIN PIGMENTS FROM RED PURPLE PITAYA FRUIT (Hylocereus polyrhizus : INFLUENCE OF PH, TEMPERATURE, METAL IONS AND ASCORBIC ACID

    Directory of Open Access Journals (Sweden)

    Tang, C.S Tang, C.S

    2010-06-01

    Full Text Available Betacyanin pigments from red-purple pitaya fruit (Hylocereus polyrhizus could be an attractive source of red colourant for food application. This paper presents results on the extraction of betacyanin pigments from pitaya fruits grown locally in Malaysia. Both the flesh of the fruit and its mesocarp were investigated and it was found that the flesh had higher pigment contents compared to its peel component. The concentration of betacyanins expressed as betanin equivalents per 100 g of flesh and peel were 10.1 ± 0.6 mg and 6.7 ± 0.2 mg, respectively when 80% methanol was used.  The stability of betacyanin pigments were investigated at different pH, temperature and in presence of different concentrations of metal ions (Cu2+ and Fe2+ and ascorbic acid. The results showed that the pigment was most stable at pH range between 5 and 6. However, it forfeited its stability to the heat induced at elevated temperatures. Metal ions (Cu2+ and Fe2+ proved to be capable of accelerating betacyanin degradation, with Cu2+ exhibiting the greatest effect. By contrast, supplementation with ascorbic acid could enhance the pigment stability against the detrimental effects caused by pH, temperature and metal ions. Nevertheless, if the concentration of ascorbic acid exceeds 0.7 %, it may change its role from pigment stabilizer to become a pro-oxidant.    Keywords: Betacyanin, pigments, pitaya fruit, Hylocereus polyrhizus, ascorbic acid

  3. Status and plans for the development of a RF negative ion source for ITER NBI

    Energy Technology Data Exchange (ETDEWEB)

    Franzen, P. [Max-Planck-Institut fuer Plasmaphysik, Postfach 1533, D-85740 Garching (Germany)]. E-mail: peter.franzen@ipp.mpg.de; Falter, H.D. [Max-Planck-Institut fuer Plasmaphysik, Postfach 1533, D-85740 Garching (Germany); Speth, E. [Max-Planck-Institut fuer Plasmaphysik, Postfach 1533, D-85740 Garching (Germany); Kraus, W. [Max-Planck-Institut fuer Plasmaphysik, Postfach 1533, D-85740 Garching (Germany); Bandyopadhyay, M. [Max-Planck-Institut fuer Plasmaphysik, Postfach 1533, D-85740 Garching (Germany); Encheva, A. [Max-Planck-Institut fuer Plasmaphysik, Postfach 1533, D-85740 Garching (Germany); Fantz, U. [Max-Planck-Institut fuer Plasmaphysik, Postfach 1533, D-85740 Garching (Germany); Franke, Th. [Max-Planck-Institut fuer Plasmaphysik, Postfach 1533, D-85740 Garching (Germany); Heinemann, B. [Max-Planck-Institut fuer Plasmaphysik, Postfach 1533, D-85740 Garching (Germany); Holtum, D. [Max-Planck-Institut fuer Plasmaphysik, Postfach 1533, D-85740 Garching (Germany); Martens, C. [Max-Planck-Institut fuer Plasmaphysik, Postfach 1533, D-85740 Garching (Germany); McNeely, P. [Max-Planck-Institut fuer Plasmaphysik, Postfach 1533, D-85740 Garching (Germany); Riedl, R. [Max-Planck-Institut fuer Plasmaphysik, Postfach 1533, D-85740 Garching (Germany); Tanga, A. [Max-Planck-Institut fuer Plasmaphysik, Postfach 1533, D-85740 Garching (Germany); Wilhelm, R. [Max-Planck-Institut fuer Plasmaphysik, Postfach 1533, D-85740 Garching (Germany)

    2005-11-15

    IPP Garching is currently developing a RF driven negative ion source for the ITER neutral beam injection system as an alternative to the present design with filamented sources. This paper reports an overview on the present status and the further prospects of the RF source development. Current densities of 26 mA/cm{sup 2} and 15 mA/cm{sup 2} have been achieved for hydrogen and deuterium, respectively, at a pressure of less than 0.5 Pa and an electron/ion ratio of 1. Size scaling experiments indicate a maximum extraction area which can be illuminated by a driver without losses of beam quality and uniformity. The preparation of a test facility for pulse lengths of up to 3600 s is proceeding; commissioning is expected end of 2004. As an intermediate step tests of a large source with the half size of the ITER source are foreseen to be commissioned in 2005.

  4. Extraction of negative hydrogen ions from a compact 14 GHz microwave ion source

    Energy Technology Data Exchange (ETDEWEB)

    Wada, M. [Faculty of Life and Medical Sciences, Doshisha University, Kyoto 610-0321 (Japan); School of Engineering, Doshisha University, Kyoto 610-0321 (Japan); Kasuya, T.; Nishida, T. [School of Engineering, Doshisha University, Kyoto 610-0321 (Japan); Kenmotsu, T. [Faculty of Life and Medical Sciences, Doshisha University, Kyoto 610-0321 (Japan); Maeno, S. [Novelion Systems Co. Ltd., D-egg Bldg. Kyoto 610-0332 (Japan); Nishiura, M. [National Institute for Fusion Science, Gifu 509-5292 (Japan); Shinto, K. [Japan Atomic Energy Agency, Aomori 039-3212 (Japan); Yamaoka, H. [Riken, Harima, Hyogo 679-5148 (Japan)

    2012-02-15

    A pair of permanent magnets has formed enough intensity to realize electron cyclotron resonance condition for a 14 GHz microwave in a 2 cm diameter 9 cm long alumina discharge chamber. A three-electrode extraction system assembled in a magnetic shielding has formed a stable beam of negative hydrogen ions (H{sup -}) in a direction perpendicular to the magnetic field. The measured H{sup -} current density was about 1 mA/cm{sup 2} with only 50 W of discharge power, but the beam intensity had shown saturation against further increase in microwave power. The beam current decreased monotonically against increasing pressure.

  5. Measurement of Ion Motional Heating Rates over a Range of Trap Frequencies and Temperatures

    CERN Document Server

    Bruzewicz, C D; Chiaverini, J

    2014-01-01

    We present measurements of the motional heating rate of a trapped ion at different trap frequencies and temperatures between $\\sim$0.6 and 1.5 MHz and $\\sim$4 and 295 K. Additionally, we examine the possible effect of adsorbed surface contaminants with boiling points below $\\sim$105$^{\\circ}$C by measuring the ion heating rate before and after locally baking our ion trap chip under ultrahigh vacuum conditions. We compare the heating rates presented here to those calculated from available electric-field noise models. We can tightly constrain a subset of these models based on their expected frequency and temperature scaling interdependence. Discrepancies between the measured results and predicted values point to the need for refinement of theoretical noise models in order to more fully understand the mechanisms behind motional trapped-ion heating.

  6. A Distributed Monitoring and Control System for the Laser Ion Source RILIS at CERN-ISOLDE

    CERN Document Server

    AUTHOR|(SzGeCERN)715185; Richter, Detlef; Wendt, Klaus

    In this work, the implementation of the LabVIEW-based RILIS Equipment Acquisition and Control Toolset (REACT) software framework is documented, revised, and further developed to accomplish remotely operated in-source laser spectroscopy experiments at CERN-ISOLDE. The Resonance Ionization Laser Ion Source (RILIS) is an integral part of the radioactive ion beam user facility ISOLDE at CERN. Its task as an ion source is to ensure high isobaric purity and production efficiency of the ion beams that are generated for the various experimental setups of the facility. Reliable operation requires directing 3 pulsed laser beams, precisely wavelength-tuned and overlapped in time to a precision of 5 nanoseconds, to converge into a 3mm diameter ion source cavity located 25m away in an inaccessible radioactive environment. These stable conditions have to be maintained for up to 7 days at a time per experiment setup. Within recent years, the array of RILIS equipment and its need to interface with other experimental apparatu...

  7. High frequency ion sound waves associated with Langmuir waves in type III radio burst source regions

    Directory of Open Access Journals (Sweden)

    G. Thejappa

    2004-01-01

    Full Text Available Short wavelength ion sound waves (2-4kHz are detected in association with the Langmuir waves (~15-30kHz in the source regions of several local type III radio bursts. They are most probably not due to any resonant wave-wave interactions such as the electrostatic decay instability because their wavelengths are much shorter than those of Langmuir waves. The Langmuir waves occur as coherent field structures with peak intensities exceeding the Langmuir collapse thresholds. Their scale sizes are of the order of the wavelength of an ion sound wave. These Langmuir wave field characteristics indicate that the observed short wavelength ion sound waves are most probably generated during the thermalization of the burnt-out cavitons left behind by the Langmuir collapse. Moreover, the peak intensities of the observed short wavelength ion sound waves are comparable to the expected intensities of those ion sound waves radiated by the burnt-out cavitons. However, the speeds of the electron beams derived from the frequency drift of type III radio bursts are too slow to satisfy the needed adiabatic ion approximation. Therefore, some non-linear process such as the induced scattering on thermal ions most probably pumps the beam excited Langmuir waves towards the lower wavenumbers, where the adiabatic ion approximation is justified.

  8. Shear flow effect on ion temperature gradient vortices in plasmas with sheared magnetic field

    DEFF Research Database (Denmark)

    Chakrabarti, N.; Juul Rasmussen, J.

    1999-01-01

    The effect of velocity shear on ion temperature gradient (ITG) driven vortices in a nonuniform plasma in a curved, sheared magnetic field is investigated. In absence of parallel ion dynamics, vortex solutions for the ITG mode are studied analytically. It is shown that under certain conditions...... and ultimately lead to a dominating monopolar form. The effects of magnetic shear indicate it may destroy these structures. (C) 1999 American Institute of Physics....

  9. Study of Effect of Ion Source Energy Spread on RFQ Beam Dynamics at REX-ISOLDE

    CERN Document Server

    Fraser, M A

    2013-01-01

    With an upgrade to the Electron Beam Ion Source (EBIS) at REX under consideration a study was launched in order to understand the effect of an increased energy spread from the ion source on the beam dynamics of the RFQ. Due to the increased electron beam potential needed to achieve the upgrade’s charge breeding specification it is expected that the energy spread of the beam will increase from today’s estimated value of approximately +-0.1%. It is shown through beam dynamics simulations that the energy spread can be increased to +-1% without significant degradation of the beam quality output by the RFQ.

  10. Empirical laws of particle extraction from single-grid source of bipolar ion-electron flow

    Science.gov (United States)

    Dudin, S. V.; Rafalskyi, D. V.

    2012-11-01

    The present research is devoted to the problem of extraction grid choice for a single-grid source of bipolar ion-electron flow. The paper contains detailed reference information on ion and electron extraction characteristics of 10 different grids with broad range of parameters: aperture width (0.09-0.6 mm), grid transparency (0.19-0.51), thickness (0.036-0.5 mm), and with different aperture geometry. The grids with square, circular, and slit apertures were made with different technologies: laser cutting, welding, weaving, and electrolytic erosion. The general regularities of the ion and electron extraction from the single-grid source are experimentally researched for the cases of dc and RF extraction grid biasing. A conclusion has been made that the maximum extracted ion current at low ion energy (0-200 eV) does not significantly vary for all the grids and does not exceed half of the primary ion current from plasma multiplied by the optical grid transparency. The low-energy limit of efficient ion extraction has been discovered which cannot be overcome by the aperture narrowing. A conclusion is made that the RF extraction mode is superior for all the researched grids since it is characterized by higher extracted ion current at any acceleration voltage for any grid with much more simple and smooth extraction curves behavior in comparison to the dc case as well as absence of arcing, jumps, and hysteresis of the measured curves at any RF voltages. The unique ability of the RF biased single-grid source of simultaneous ion/electron emission has been studied. The measured maximal attainable ion beam current compensation ratio is always sufficiently higher than 1 and typically varies in the range 2-6. The results obtained in the present paper demonstrate prospective of the single-grid source in space thruster applications and in modern technologies, particularly for ion beam processing of wide bandgap semiconductor devices such as GaN and SiC transistors due to inherent

  11. Ion temperature anisotropy effects on threshold conditions of a shear-modified current driven electrostatic ion-acoustic instability in the topside auroral ionosphere

    Directory of Open Access Journals (Sweden)

    P. J. G. Perron

    2013-03-01

    Full Text Available Temperature anisotropies may be encountered in space plasmas when there is a preferred direction, for instance, a strong magnetic or electric field. In this paper, we study how ion temperature anisotropy can affect the threshold conditions of a shear-modified current driven electrostatic ion-acoustic (CDEIA instability. In particular, this communication focuses on instabilities in the context of topside auroral F-region situations and in the limit where finite Larmor radius corrections are small. We derived a new fluid-like expression for the critical drift which depends explicitly on ion anisotropy. More importantly, for ion to electron temperature ratios typical of F-region, solutions of the kinetic dispersion relation show that ion temperature anisotropy may significantly lower the drift threshold required for instability. In some cases, a perpendicular to parallel ion temperature ratio of 2 and may reduce the relative drift required for the onset of instability by a factor of approximately 30, assuming the ion-acoustic speed of the medium remains constant. Therefore, the ion temperature anisotropy should be considered in future studies of ion-acoustic waves and instabilities in the high-latitude ionospheric F-region.

  12. Effects of electron-ion temperature equilibration on inertial confinement fusion implosions.

    Science.gov (United States)

    Xu, Barry; Hu, S X

    2011-07-01

    The electron-ion temperature relaxation essentially affects both the laser absorption in coronal plasmas and the hot-spot formation in inertial confinement fusion (ICF). It has recently been reexamined for plasma conditions closely relevant to ICF implosions using either classical molecular-dynamics simulations or analytical methods. To explore the electron-ion temperature equilibration effects on ICF implosion performance, we have examined two Coulomb logarithm models by implementing them into our hydrocodes, and we have carried out hydrosimulations for ICF implosions. Compared to the Lee-More model that is currently used in our standard hydrocodes, the two models predict substantial differences in laser absorption, coronal temperatures, and neutron yields for ICF implosions at the OMEGA Laser Facility [Boehly et al. Opt. Commun. 133, 495 (1997)]. Such effects on the triple-picket direct-drive design at the National Ignition Facility (NIF) have also been explored. Based on the validity of the two models, we have proposed a combined model of the electron-ion temperature-relaxation rate for the overall ICF plasma conditions. The hydrosimulations using the combined model for OMEGA implosions have shown ∼6% more laser absorption, ∼6%-15% higher coronal temperatures, and ∼10% more neutron yield, when compared to the Lee-More model prediction. It is also noticed that the gain for the NIF direct-drive design can be varied by ∼10% among the different electron-ion temperature-relaxation models.

  13. Optimization of caesium dynamics in large and powerful RF sources for negative hydrogen ions

    Energy Technology Data Exchange (ETDEWEB)

    Mimo, Alessandro; Wimmer, Christian; Wuenderlich, Dirk; Fantz, Ursel [Max-Planck-Institut fuer Plasmaphysik, 85748 Garching (Germany)

    2015-05-01

    The development of large and powerful RF sources for negative hydrogen and deuterium ions is mandatory for the realization of the Neutral Beam Injection system at ITER. Caesium seeding into negative ion sources is necessary to obtain the required ion current with a tolerable level of co-extracted electrons. The caesium dynamics, during both plasma and vacuum phases, was investigated by means of the Monte Carlo transport code CsFlow3D, which is used to simulate the time evolution of the distribution of neutral and ionic caesium in the IPP prototype RF ion source. Simulations were performed for different durations of plasma-on and plasma-off phases, with the purpose of understanding how the duty cycle influences the caesium distribution and hence the source performance. In order to investigate asymmetry effects in the caesium distribution, caused by the positioning of caesium evaporator, the caesium coverage on the top and on the bottom part of the plasma grid was simulated and data were compared to the caesium density measured by laser absorption in the prototype source. The next step will be to introduce in the code the simulation of diagnostics such as laser absorption spectroscopy and optical emission spectroscopy, in order to achieve a direct benchmark of the code with experimental data.

  14. Measurements on Pb27+ Sources for the CERN Heavy Ion Injection Chain

    CERN Document Server

    Chamings, J A

    2004-01-01

    CERN, the world's largest particle physics laboratory near Geneva, is currently in the process of building the Large Hadron Collider (LHC). Lead-208 will be used in this accelerator and to meet the injection requirements much work is required to find a suitable and reliable heavy ion source. The work in this report covers two ion sources, the Laser Ion Source (LIS), and the Electron Cyclotron Resonance Ion Source (ECRIS). An emittance measurement, using a pepper pot and CCD camera, was completed on the recently re-installed LIS, measured and analysed to be 140mm.mrad un-normalised and 0.8mm.mrad normalised 4rms for the maximum intensity charge state, Pb27+. A Visual Basic Program was modified to allow Charge State Distribution (CSD) and other scans of the ECRIS at CERN to be taken. Chapter 5 presents the results of the CSD scans taken. This program provided a new method to take 1 dimensional transverse beam profiles. From this a direct emittance measurement was formed for the first time since the source was o...

  15. Determination of discharge parameters via OES at the Linac4 H{sup −} ion source

    Energy Technology Data Exchange (ETDEWEB)

    Briefi, S., E-mail: stefan.briefi@physik.uni-augsburg.de [AG Experimentelle Plasmaphysik, Institut für Physik, Universität Augsburg, 86135 Augsburg (Germany); Fink, D.; Mattei, S.; Lettry, J. [Linac4 Ion Source Team, CERN-ABP, 1211 Geneva 23 (Switzerland); Fantz, U. [AG Experimentelle Plasmaphysik, Institut für Physik, Universität Augsburg, 86135 Augsburg (Germany); Max-Planck-Institut für Plasmaphysik, Boltzmannstraße 2, 85748 Garching (Germany)

    2016-02-15

    Optical emission spectroscopy (OES) measurements of the atomic Balmer series and the molecular Fulcher transition have been carried out at the Linac4 ion source in order to determine plasma parameters. As the spectroscopic system was only relatively calibrated, the data evaluation only yielded rough estimates of the plasma parameters (T{sub e} ≈ 1.2 eV, n{sub e} ≈ 1 × 10{sup 19} m{sup −3}, and n{sub H}/n{sub H{sub 2}} ≈ 0.5 at standard operational parameters). The analysis of the Fulcher transition revealed a non-thermal “hockey-stick” rotational population of the hydrogen molecules. At varying RF power, the measurements at the on-axis line of sight (LOS) showed a peak in the rotational temperatures between 25 and 40 kW of RF power, whereas a steady decrease with power was observed at a tilted LOS, indicating the presence of strong plasma parameter gradients.

  16. The Effect of Nuclear Elastic Scattering on Temperature Equilibration Rate of Ions in Fusion Plasma

    Directory of Open Access Journals (Sweden)

    M. Mahdavi

    2014-01-01

    Full Text Available A plasma with two different particle types and at different temperatures has been considered, so that each type of ion with Maxwell-Boltzmann distribution function is in temperature equilibrium with itself. Using the extracted nuclear elastic scattering differential cross-section from experimental data, solving the Boltzmann equation, and also taking into account the mobility of the background particles, temperature equilibration rate between two different ions in a fusion plasma is calculated. The results show that, at higher temperature differences, effect of nuclear elastic scattering is more important in calculating the temperature equilibration rate. The obtained expressions have general form so that they are applicable to each type of particle for background (b and each type for projectile (p. In this paper, for example, an equimolar Deuterium-Hydrogen plasma with density n=5×1025 cm−3 is chosen in which the deuteron is the background particle with temperature (also electron temperature Tb=1 keV (usual conditions for a fusion plasma at the ignition instant and the proton is the projectile with temperature Tp>Tb. These calculations, particularly, are very important for ion fast ignition in inertial confinement fusion concept.

  17. Determination of the core temperature of a Li-ion cell during thermal runaway

    Science.gov (United States)

    Parhizi, M.; Ahmed, M. B.; Jain, A.

    2017-12-01

    Safety and performance of Li-ion cells is severely affected by thermal runaway where exothermic processes within the cell cause uncontrolled temperature rise, eventually leading to catastrophic failure. Most past experimental papers on thermal runaway only report surface temperature measurement, while the core temperature of the cell remains largely unknown. This paper presents an experimentally validated method based on thermal conduction analysis to determine the core temperature of a Li-ion cell during thermal runaway using surface temperature and chemical kinetics data. Experiments conducted on a thermal test cell show that core temperature computed using this method is in good agreement with independent thermocouple-based measurements in a wide range of experimental conditions. The validated method is used to predict core temperature as a function of time for several previously reported thermal runaway tests. In each case, the predicted peak core temperature is found to be several hundreds of degrees Celsius higher than the measured surface temperature. This shows that surface temperature alone is not sufficient for thermally characterizing the cell during thermal runaway. Besides providing key insights into the fundamental nature of thermal runaway, the ability to determine the core temperature shown here may lead to practical tools for characterizing and mitigating thermal runaway.

  18. Ambient mass spectrometry employing direct analysis in real time (DART) ion source for olive oil quality and authenticity assessment

    Energy Technology Data Exchange (ETDEWEB)

    Vaclavik, Lukas; Cajka, Tomas; Hrbek, Vojtech [Institute of Chemical Technology Prague, Faculty of Food and Biochemical Technology, Department of Food Chemistry and Analysis, Technicka 5, 166 28 Prague 6 (Czech Republic); Hajslova, Jana, E-mail: jana.hajslova@vscht.cz [Institute of Chemical Technology Prague, Faculty of Food and Biochemical Technology, Department of Food Chemistry and Analysis, Technicka 5, 166 28 Prague 6 (Czech Republic)

    2009-07-10

    A novel approach for the authentication of olive oil samples representing different quality grades has been developed. A new type of ion source, direct analysis in real time (DART), coupled to a high-resolution time-of-flight mass spectrometer (TOFMS) was employed for the comprehensive profiling of triacylglycerols (TAGs) and/or polar compounds extracted with a methanol-water mixture. The main parameters influencing the ionization efficiency of TAGs were the type of sample solvent, degree of sample dilution, ion beam temperature, and presence of a dopant (ammonia vapors). The ionization yield of polar compounds depended mainly on a content of water in the extract and ion beam temperature. Using DART-TOFMS, not only differentiation among extra virgin olive oil (EVOO), olive pomace oil (OPO) and olive oil (OO) could be easily achieved, but also EVOO adulteration with commonly used adulterant, hazelnut oil (HO), was feasible. Based on the linear discriminant analysis (LDA), the introduced method allowed detection of HO addition of 6 and 15% (v/v) when assessing DART-TOFMS mass profiles of polar compounds and TAGs, respectively.

  19. Status of the project TRAPSENSOR: Performance of the laser-desorption ion source

    Energy Technology Data Exchange (ETDEWEB)

    Cornejo, J.M.; Lorenzo, A. [Departamento de Física Atómica, Molecular y Nuclear, Universidad de Granada, 18071 Granada (Spain); Renisch, D. [Institut für Kernchemie, Johannes Gutenberg-Universität, 55099 Mainz (Germany); Block, M. [GSI Helmholtzzentrum für Schwerionenforschung, Planckstrasse 1, 64291 Darmstadt (Germany); Düllmann, Ch.E. [Institut für Kernchemie, Johannes Gutenberg-Universität, 55099 Mainz (Germany); GSI Helmholtzzentrum für Schwerionenforschung, Planckstrasse 1, 64291 Darmstadt (Germany); SHE Chemistry section, Helmholtz-Institut Mainz, 55099 Mainz (Germany); Rodríguez, D., E-mail: danielrodriguez@ugr.es [Departamento de Física Atómica, Molecular y Nuclear, Universidad de Granada, 18071 Granada (Spain)

    2013-12-15

    Highlights: • Description of the status of the project TRAPSENSOR. • Study of a laser desorption ion source to perform experiments with Penning traps. • Production of calcium, rhenium and osmium ions by laser desorption for precision experiments. -- Abstract: Penning traps provide mass measurements on atomic nuclei with the highest accuracy and sensitivity. Depending on the experiment and on the physics goal, a relative mass uncertainty varying from 10{sup −7} to below 10{sup −11} is required. Regarding sensitivity, the use of only one ion for the measurement is crucial, either to perform mass measurements on superheavy elements (SHE), or to reach δm/m≈10{sup -11} in order to contribute to the direct determination of the mass of the electron-antineutrino with accurate mass measurements on specific nuclei. This has motivated the development of a new technique called Quantum Sensor based on a laser-cooled ion stored in a Penning trap, to perform mass measurements using fluorescence photons instead of electronic detection. The device is currently under development at the University of Granada (Spain) within the project TRAPSENSOR. We describe the physics which motivates the construction of this device, the expected performance of the Quantum Sensor compared to that from existing techniques, and briefly present the main components of the project. As a specific aspect of the project, the performance of the laser-desorption ion source utilized to produce calcium, rhenium and osmium ions at different kinetic energies is presented.

  20. Modernization of high-power (5 kW) broad ion beam source

    Science.gov (United States)

    Emlin, D. R.; Gavrilov, N. V.; Tretnikov, P. V.; Nasyrov, V. F.; Timerbaev, A. Z.

    2017-05-01

    In the course of the long-term performance (during 5 years) of a high-power source of gas ions (25 keV, 0.2 A, 600 cm2) with a plasma emitter based on cold cathode discharge, the character and rate of key constructive elements faults were determined, which allowed to calculate the inter-repair time, complexity and cost of the repair. The peculiarities of the gas-discharge system and the ion beam forming system limiting the effectiveness of ion beam treatment were revealed as well. Conditions favorable for the decrease in the discharge voltage by 50-200 V and igniting voltage up to 1.5-2 times are determined. The possibilities of lowering the minimal flow of working gas are demonstrated. The design of the discharge system with reduced sputtering rate of local areas of the hollow cathode is offered. The changes added to ion source design aimed to enhance the lifetime of the plasma chamber that is exposed to cyclic heating by the back electron beam leading to the development of through cracks, and to enlarge the rupture life of glow discharge hollow cathode by optimizing its configuration and the conditions of discharge ignition and burning, are described. The upgraded design of a multislit ion-optical system with enhanced performance ensures uniform surface distribution of ion fluence.

  1. Highly textured zinc oxide films by room temperature ion beam assisted deposition

    Energy Technology Data Exchange (ETDEWEB)

    Koehl, D.; Wuttig, M. [I. Institute of Physics, RWTH Aachen University (Germany); Luysberg, M. [Ernst Ruska-Zentrum fuer Mikroskopie und Spektroskopie mit Elektronen/IFF, Forschungszentrum Juelich (Germany)

    2009-10-15

    A new ion beam assisted sputter deposition technique has been developed which facilitates room temperature fabrication of thin ZnO films with exceptional structural order. The well-defined texture of these films is comparable to films deposited at elevated temperatures of typically 200-300 C in standard sputter processes. Structural investigations reveal that the applied Xe{sup +} ion bombardment mainly affects the nucleation of ZnO crystallites. The high structural order of the nucleation layer is maintained in subsequent stages of film growth. (copyright 2009 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  2. Effects of ion temperature fluctuations on the stability of resistive ballooning modes

    Energy Technology Data Exchange (ETDEWEB)

    Singh, R. [Inst. for Plasma Research, Bhat, Gandhinagar (India); Nordman, H.; Jarmen, A.; Weiland, J. [Chalmers Univ. of Technology, Goeteborg (Sweden). Inst. for Electromagnetic Field Theory and Plasma Physics

    1996-11-01

    The influence of ion temperature fluctuations on the stability of resistive drift- and ballooning-modes is investigated using a two-fluid model. The Eigenmode equations are derived and solved analytically in a low beta model equilibrium. Parameters relevant to L-mode edge plasmas from the Texas Experimental Tokamak are used. The resistive modes are found to be destabilized by ion temperature fluctuations over a broad range of mode numbers. The scaling of the growth rate with magnetic shear and mode number is elucidated. 13 refs, 4 figs.

  3. Ion pair formation in copper sulfate aqueous solutions at high temperatures

    Energy Technology Data Exchange (ETDEWEB)

    Mendez De Leo, Lucila P. [Unidad de Actividad Quimica, Comision Nacional de Energia, Avenida del Libertador 8250, 1429 Ciudad de Buenos Aires (Argentina); Escuela de Ciencia y Tecnologia, Universidad Nacional General San Martin, Alem 3901, 1653 Villa Ballester (Argentina); Bianchi, Hugo L. [Unidad de Actividad Quimica, Comision Nacional de Energia, Avenida del Libertador 8250, 1429 Ciudad de Buenos Aires (Argentina); Escuela de Ciencia y Tecnologia, Universidad Nacional General San Martin, Alem 3901, 1653 Villa Ballester (Argentina); Fernandez-Prini, Roberto [Unidad de Actividad Quimica, Comision Nacional de Energia, Avenida del Libertador 8250, 1429 Ciudad de Buenos Aires (Argentina) and INQUIMAE, Facultad de Ciencias Exactas y Naturales, Universidad de Buenos Aires, Ciudad Universitaria, Pabellon II, 1428 Ciudad de Buenos Aires (Argentina)]. E-mail: rfprini@cnea.gov.ar

    2005-05-15

    Ionic association between Cu{sup 2+}(aq) and SO42-(aq) has been studied in the temperature range (298 to 473) K using a spectrophotometric technique. Experiments were designed to minimize the contribution of other protolytic equilibria in solution. The values of the ionic association equilibrium constant at different temperatures and pressures were fitted to an appropriate equation that allows the calculation of the thermodynamic quantities for states close to the saturation line. Using Bjerrum's model for ionic association evidence for two ion pair populations was obtained. The process of ion pairing is discussed and a possibility to reconcile the continuum model (Bjerrum) with molecular simulation results is suggested.

  4. Summer student project report - A versatile ion source for improving the sensitivity and resolution of the CRIS beamline at ISOLDE

    CERN Document Server

    AUTHOR|(CDS)2156312

    2016-01-01

    The main part of my project involved working on the independent ion source attached to the collinear resonance ionisation spectroscopy experiment at ISOLDE. The primary aim was to increase the maximum accelerating potential from 5 kV to 30 kV, to become comparable to ion beams from the ISOLDE High Resolution Separator and to improve the resolution of hyperfine structure measurements. The new ion source allows for easy exchange between surface and plasma ion sources, as well as use as a laser ion source. The work included disassembling and rebuilding the ion optics, electronics and vacuum systems, adding new features such as a laser window. This was done in parallel with simulations of other parts of the beamline and in- volvement in online experiments. We were successful in reaching 30 kV and plan to produce beams of ions in the near future to investigate the sensitivity of various ionisation schemes.

  5. Meniscus and beam halo formation in a tandem-type negative ion source with surface production

    Energy Technology Data Exchange (ETDEWEB)

    Miyamoto, K. [Naruto University of Education, 748 Nakashima, Takashima, Naruto-cho, Naruto-shi, Tokushima 772-8502 (Japan); Okuda, S.; Hatayama, A. [Faculty of Science and Technology, Keio University, 3-14-1 Hiyoshi, Kohoku-ku, Yokohama 223-8522 (Japan)

    2012-06-04

    A meniscus of plasma-beam boundary in H{sup -} ion sources largely affects the extracted H{sup -} ion beam optics. Although it is hypothesized that the shape of the meniscus is one of the main reasons for the beam halo observed in experiments, a physical mechanism of the beam halo formation is not yet fully understood. In this letter, it is first shown by the 2D particle in cell simulation that the H{sup -} ions extracted from the periphery of the meniscus cause a beam halo since the surface produced H{sup -} ions penetrate into the bulk plasma, and, thus, the resultant meniscus has a relatively large curvature.

  6. Status of charge breeding with electron cyclotron resonance ion sources (invited)

    CERN Document Server

    Lamy, T; Sortais, P; Thuillier, T; 10.1063/1.2149300

    2006-01-01

    Due to the production methods of exotic nuclei, an efficient acceleration of radioactive ion beams needs charge breeding of weakly charged ions. The upgrade of existing isotope separator on-line facilities (TRIUMF-isotope separation and acceleration, CERN-isotope separation on-line detector, etc.) or the development of projects for the acceleration of radioactive ion beams (GANIL-SPIRAL2, MAFF, EURISOL, etc.) requires charge breeders with high efficiency, fast charge breeding time, low background levels, and high intensity acceptance either in continuous or in pulsed mode. The optimization of these parameters is a challenge for the electron cyclotron resonance (ECR) community and is useful to get a better understanding of plasma physics in ECR ion sources (ECRISs). The ECR charge breeding technique has been developed for more than ten years at LPSC (former ISN) Grenoble, typical 1+rightward arrown+ efficiencies are in the 3%-10% range depending on the nature of the incoming beam (metallic, alkaline, and gaseo...

  7. Temperature determination using Kalpha spectra from M -shell Ti ions.

    Science.gov (United States)

    Hansen, S B; Faenov, A Ya; Pikuz, T A; Fournier, K B; Shepherd, R; Chen, H; Widmann, K; Wilks, S C; Ping, Y; Chung, H K; Niles, A; Hunter, J R; Dyer, G; Ditmire, T

    2005-09-01

    The compact multipulse terawatt (COMET) laser facility at LLNL was used to irradiate Al-coated 2-50 microm Ti foils with approximately 10(19) W cm(-2) , 500 fs, 3-6 J laser pulses. Laser-plasma interactions on the front side of the target generate hot electrons with sufficient energy to excite inner-shell electrons in Ti, creating Kalpha emission which has been measured using a focusing spectrometer with spatial resolution aimed at the back surface of the targets. The spatial extent of the emission varies with target thickness. The high spectral resolution (lambda/Deltalambda approximately equal to 3800) is sufficient to measure broadening of the Kalpha emission feature due to the emergence of blueshifted satellites from ionized Ti in a heated region of the target. A self-consistent-field model is used to spectroscopically diagnose thermal electron temperatures up to 40 eV in the strongly coupled Ti plasmas.

  8. Modelling of caesium dynamics in the negative ion sources at BATMAN and ELISE

    Science.gov (United States)

    Mimo, A.; Wimmer, C.; Wünderlich, D.; Fantz, U.

    2017-08-01

    The knowledge of Cs dynamics in negative hydrogen ion sources is a primary issue to achieve the ITER requirements for the Neutral Beam Injection (NBI) systems, i.e. one hour operation with an accelerated ion current of 40 A of D- and a ratio between negative ions and co-extracted electrons below one. Production of negative ions is mostly achieved by conversion of hydrogen/deuterium atoms on a converter surface, which is caesiated in order to reduce the work function and increase the conversion efficiency. The understanding of the Cs transport and redistribution mechanism inside the source is necessary for the achievement of high performances. Cs dynamics was therefore investigated by means of numerical simulations performed with the Monte Carlo transport code CsFlow3D. Simulations of the prototype source (1/8 of the ITER NBI source size) have shown that the plasma distribution inside the source has the major effect on Cs dynamics during the pulse: asymmetry of the plasma parameters leads to asymmetry in Cs distribution in front of the plasma grid. The simulated time traces and the general simulation results are in agreement with the experimental measurements. Simulations performed for the ELISE testbed (half of the ITER NBI source size) have shown an effect of the vacuum phase time on the amount and stability of Cs during the pulse. The sputtering of Cs due to back-streaming ions was reproduced by the simulations and it is in agreement with the experimental observation: this can become a critical issue during long pulses, especially in case of continuous extraction as foreseen for ITER. These results and the acquired knowledge of Cs dynamics will be useful to have a better management of Cs and thus to reduce its consumption, in the direction of the demonstration fusion power plant DEMO.

  9. [Correlativity analysis based on radiation spectrum of correlated color temperature and thermodynamic temperature of a radiating source].

    Science.gov (United States)

    Fu, Tai-ran; Cheng, Xiao-fang; Zhong, Mao-hua; Yang, Zang-jian

    2006-11-01

    Correlated color temperature, which describes the chromaticity characteristics of a radiating source, is different from its thermodynamic temperature derived from primary spectrum pyrometry. However, establishing their mathematical relationship is feasible. Therefore, the authors theoretically analyzed the variation rule of the correlativity difference between the correlated color temperature of the source and its thermodynamic temperature with the emissivity parameter. And the authors gave the corresponding numerical simulation results. The above theoretical and numerical discussions will make it possible that a colorimeter used to measure the correlated color temperature serves as a pyrometer to realize the measurement of the thermodynamic temperature.

  10. Development of a RF-driven ion source for the ITER NBI system

    Energy Technology Data Exchange (ETDEWEB)

    Staebler, A. [Max-Planck-Institut fuer Plasmaphysik, EURATOM Association, 85748 Garching (Germany)], E-mail: albrecht.staebler@ipp.mpg.de; Fantz, U.; Franzen, P.; Berger, M.; Christ-Koch, S.; Falter, H.D.; Froeschle, M.; Gutser, R.; Heinemann, B.; Holtum, D.; Kraus, W.; Martens, C.; McNeely, P.; Nocentini, R.; Obermayer, S.; Riedl, R.; Speth, E.; Wuenderlich, D. [Max-Planck-Institut fuer Plasmaphysik, EURATOM Association, 85748 Garching (Germany)

    2009-06-15

    Extensive R and D work on RF-driven negative hydrogen ion sources carried out at IPP Garching led to the decision of ITER to select this type of source as the new reference source for the ITER NBI system. The principle suitability of the RF source has been demonstrated in a small scale, short pulse length experiment: accelerated current densities, co-extracted electron currents at a source operation pressure, all well inside the range of the ITER requirements have been achieved simultaneously. In subsequent experiments, pulse lengths up to 1 h and the possibility of modularly extending the source to ITER source dimensions were demonstrated. The results achieved at the various IPP test beds, the lessons learnt during optimising the source for negative ion production and extraction as well as the problems still to be solved are summarized. As the next step in support of the NBI development for ITER, IPP plans to build a new test facility for beam extraction from a source of half the size for ITER.

  11. Ion Source with Laser Triangulation for Ambient Mass Spectrometry of Nonplanar Samples.

    Science.gov (United States)

    Rejšek, Jan; Vrkoslav, Vladimír; Pokorný, Vít; Přibyl, Vladimír; Cvačka, Josef

    2017-11-07

    The analysis of nonplanar samples in ambient mass spectrometry poses a formidable challenge. Here, an ion source equipped with laser triangulation for analyzing nonplanar surfaces was constructed. It was designed as a two-position device, where the sample height was measured using laser triangulation and the target compounds were then analyzed. Thanks to a stage movable in xyz, the ion source maintained an optimal vertical distance between the sample and the sampling capillary for each measured spot during the surface analysis. The xyz-coordinates for the movement of the sample stage were computed using the laser sensor data in such a way as to avoid direct contact of the sampling capillary and the measured surface. The ion source performance and its ability to analyze various morphologies were tested using desorption electrospray ionization with plastic objects coated by 2,5-dimethoxybenzoic acid. The experiments showed excellent performance for nonplanar samples but also revealed some limitations especially on object edges and steep slopes. The applicability of the ion source operated in desorption electrospray ionization and desorption atmospheric pressure photoionization was examined for food and pharmaceutical samples. Chemicals on the surface of nonplanar samples were probed along a line extending across the surface of the measured objects. The device provided high-quality spectra, regardless of the sample height at the measured spot. The automatic adjustments of the sample stage in xyz proved to be beneficial for analyzing nonplanar samples and for simultaneous measurement of samples with various dimensions and shapes.

  12. Recent developments of long pulse RF ion sources for NBI systems

    Energy Technology Data Exchange (ETDEWEB)

    Kraus, W. E-mail: wrk@ipp.mpg.de; Franzen, P.; Heinemann, B.; Speth, E.; Vollmer, O

    2001-10-01

    For the new radial injector of the Wendelstein 7-AS stellerator, two medium size 40 kW RF sources ('W7-AS RF source') have been built and tested. A positive hydrogen ion beam of 28 A at 50 kV with a proton fraction of 60% has been extracted. For future injection systems, in particular those based on negative ions, large area beam extraction and long pulse capability up to cw operation are envisaged. At IPP two different design concepts of RF sources are being investigated in order to meet these requirements: in the first one, the plasma is generated in one or two small circular RF sources ('drivers'), which are mounted onto the back plate of a 30 l expansion volume ('bucket') with magnetic multi-cusp confinement of the plasma ('Type 6-1' and 'Type 6-2' respectively). In the second concept the plasma is generated inside the bucket by an internal RF coil, which is insulated by a quartz tube ('Type 5'). In both cases the applicability for negative as well as for positive ion production is being tested. The next application will be in the positive ion based injectors in the third injector of JET and in the W7X stellerator.

  13. Upgrade and experimental results of radio frequency ion source for neutral beam injector

    Energy Technology Data Exchange (ETDEWEB)

    Xie, Yahong, E-mail: xieyh@ipp.ac.cn [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); Hu, Chundong [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); Jiang, Caichao [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); Graduate school, University of Science and Technology of China, Hefei 230026 (China); Gu, Yuming; Xu, Yongjian; Chen, Shiyong; Liang, Lizhen; Liu, Zhimin; Xie, Yuanlai [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China)

    2017-01-15

    Highlights: • The RF ion source was developed in ASIPP for the first time. • The gas control was employed for the initial plasma production successfully. • The RF power was controlled for the stable plasma generation with high power. • Long pulse operation was tested and analyzed with 400 s. - Abstract: A radio frequency (RF) ion source was designed and developed for neutral beam injector in Institute of Plasma Physics, Chinese Academy of Sciences (ASIPP). Recently, the RF ion source was upgraded with new RF power generator (50 kW with frequency of 1 MHz), a new matching unit and the faraday shield with water cooling. Two new methods were used for the ion source tests on the test bed. The high pressure was used for the ignition of plasma and change to low pressure of 0.3 Pa to maintain the plasma. The RF plasma can be generated without the start filament successfully. In order to avoid the plasma oscillation with high power, the RF power was set to increase with two stages without change the matching unit. High power of 46 kW with pulse length of 22 s was achieved on the test bed and the plasma duration can be extended too.

  14. Power efficiency improvements with the radio frequency H{sup −} ion source

    Energy Technology Data Exchange (ETDEWEB)

    Kalvas, T., E-mail: taneli.kalvas@jyu.fi; Tarvainen, O.; Komppula, J.; Koivisto, H.; Tuunanen, J. [Department of Physics, University of Jyväskylä, P.O. Box 35 (YFL), FI-40014 Jyväskylä (Finland); Potkins, D.; Stewart, T.; Dehnel, M. [D-Pace, Inc., P.O. Box 201, Nelson, British Columbia V1L 5P9 (Canada)

    2016-02-15

    CW 13.56 MHz radio frequency-driven H{sup −} ion source is under development at the University of Jyväskylä for replacing an existing filament-driven ion source at the MCC30/15 cyclotron. Previously, production of 1 mA H{sup −} beam, which is the target intensity of the ion source, has been reported at 3 kW of RF power. The original ion source front plate with an adjustable electromagnet based filter field has been replaced with a new front plate with permanent magnet filter field. The new structure is more open and enables a higher flux of ro-vibrationally excited molecules towards the plasma electrode and provides a better control of the potential near the extraction due to a stronger separation of the main plasma from the plasma electrode. While the original system provided better control over the e{sup −}/H{sup −} ratio, the new configuration has led to a higher production efficiency of 1 mA H{sup −} at 1.75 kW RF power. The latest results and upgrade plans are presented.

  15. Improvements of the magnetic field design for SPIDER and MITICA negative ion beam sources

    Energy Technology Data Exchange (ETDEWEB)

    Chitarin, G., E-mail: chitarin@igi.cnr.it [Consorzio RFX, C.so Stati Uniti 4, 35129 Padova (Italy); University of Padova, Dept. of Management and Engineering, Strad. S. Nicola 3, 36100 Vicenza (Italy); Agostinetti, P.; Aprile, D.; Marconato, N.; Veltri, P. [Consorzio RFX, C.so Stati Uniti 4, 35129 Padova (Italy)

    2015-04-08

    The design of the magnetic field configuration in the SPIDER and MITICA negative ion beam sources has evolved considerably during the past four years. This evolution was driven by three factors: 1) the experimental results of the large RF-driven ion sources at IPP, which have provided valuable indications on the optimal magnetic configurations for reliable RF plasma source operation and for large negative ion current extraction, 2) the comprehensive beam optics and heat load simulations, which showed that the magnetic field configuration in the accelerator is crucial for keeping the heat load due to electrons on the accelerator grids within tolerable limits, without compromising the optics of the negative ion beam in the foreseen operating scenarios, 3) the progress of the detailed mechanical design of the accelerator, which stimulated the evaluation of different solutions for the correction of beamlet deflections of various origin and for beamlet aiming. On this basis, new requirements and solution concepts for the magnetic field configuration in the SPIDER and MITICA beam sources have been progressively introduced and updated until the design converged. The paper presents how these concepts have been integrated into a final design solution based on a horizontal “long-range” field (few mT) in combination with a “local” vertical field of some tens of mT on the acceleration grids.

  16. Study of the general plasma characteristics of a high power multifilament ion source

    Energy Technology Data Exchange (ETDEWEB)

    Schoenberg, K.F.

    1979-09-01

    A general assessment of the steady state and time dependent plasma properties which characterize a high power multifilament ion source is presented. Steady state measurements, obtained via a pulsed electrostatic probe data acquisition system, are described. Fluctuation measurements, obtained via a broadband digital spectral analysis system, are also given.

  17. Low-temperature technique of thin silicon ion implanted epitaxial detectors

    Energy Technology Data Exchange (ETDEWEB)

    Kordyasz, A.J.; Bednarek, A. [Warsaw University, Heavy Ion Laboratory, Warsaw (Poland); Le Neindre, N.; Bougault, R.; Lopez, O.; Merrer, Y.; Vient, E. [Universite de Caen, LPC, IN2P3-CNRS, ENSICAEN, Caen-Cedex (France); Parlog, M. [Universite de Caen, LPC, IN2P3-CNRS, ENSICAEN, Caen-Cedex (France); ' ' Horia Hulubei' ' National Institute of Physics and Nuclear Engineering (IFIN-HH), Bucharest Magurele (Romania); Casini, G.; Poggi, G.; Bini, M.; Valdre, S.; Scarlini, E.; Pasquali, G.; Pastore, G.; Piantelli, S.; Stefanini, A.; Olmi, A.; Barlini, S. [INFN Firenze, Sesto Fiorentino (Italy); Universita di Firenze, Sesto Fiorentino (Firenze) (Italy); Kowalczyk, M. [Warsaw University, Heavy Ion Laboratory, Warsaw (Poland); University of Warsaw, Institute of Experimental Physics, Warsaw (Poland); Frankland, J.D.; Bonnet, E.; Chbihi, A.; Gruyer, D. [CEA et IN2P3-CNRS, GANIL, Caen-Cedex 05 (France); Borderie, B.; Ademard, G.; Edelbruck, P.; Rivet, M.F.; Salomon, F. [IN2P3-CNRS, Institut de Physique Nucleaire, Orsay-Cedex (France); Boiano, A.; Rosato, E.; Meoli, A.; Ordine, A.; Spadaccini, G.; Tortone, G.; Vigilante, M.; Vanzanella, E. [Universita di Napoli ' ' Federico II' ' , Dipartimento di Scienze Fisiche, Napoli (Italy); INFN, Napoli (Italy); Bruno, M.; Serra, S.; Morelli, L.; Guerzoni, M. [INFN, Bologna (Italy); Universita di Bologna, Bologna (Italy); Alba, R.; Santonocito, D.; Maiolino, C. [INFN, Catania (Italy); Universita di Catania, LNS, Catania (Italy); Cinausero, M.; Gramegna, F.; Marchi, T. [INFN LNL Legnaro, Legnaro (Padova) (Italy); Kozik, T.; Kulig, P.; Twarog, T.; Sosin, Z. [Jagiellonian University, Cracow (Poland); Gasior, K.; Grzeszczuk, A.; Zipper, W. [University of Silesia, Silesian University, Katowice (Poland); Sarnecki, J.; Lipinski, D.; Wodzinska, H.; Brzozowski, A.; Teodorczyk, M.; Gajewski, M.; Zagojski, A.; Krzyzak, K. [Institute of Electronic Materials Technology, Warsaw (Poland); Tarasiuk, K.J. [University of Warsaw, Institute of Experimental Physics, Warsaw (Poland); Khabanowa, Z. [Faculty of Physics, Warsaw University of Technology, Warsaw (Poland); Kordyasz, L. [Warsaw University of Technology, Faculty of Mechatronics, Institute of Mikromechanics and Photonics, Department of Design of Precision Devices, Warsaw (Poland)

    2015-02-01

    A new technique of large-area thin ion implanted silicon detectors has been developed within the R and D performed by the FAZIA Collaboration. The essence of the technique is the application of a low-temperature baking process instead of high-temperature annealing. This thermal treatment is performed after B{sup +} ion implantation and Al evaporation of detector contacts, made by using a single adjusted Al mask. Extremely thin silicon pads can be therefore obtained. The thickness distribution along the X and Y directions was measured for a prototype chip by the energy loss of α-particles from {sup 241}Am (left angle E{sub α} right angle = 5.5 MeV). Preliminary tests on the first thin detector (area ∼ 20 x 20 mm{sup 2}) were performed at the INFN-LNS cyclotron in Catania (Italy) using products emitted in the heavy-ion reaction {sup 84}Kr (E = 35 A MeV) + {sup 112}Sn. The ΔE - E ion identification plot was obtained using a telescope consisting of our thin ΔE detector (21 μm thick) followed by a typical FAZIA 510 μm E detector of the same active area. The charge distribution of measured ions is presented together with a quantitative evaluation of the quality of the Z resolution. The threshold is lower than 2 A MeV depending on the ion charge. (orig.)

  18. Significant stress reduction of cBN layers upon ion irradiation at elevated temperatures

    Energy Technology Data Exchange (ETDEWEB)

    Weidner, Stefan; Geburt, Sebastian; Ronning, Carsten [Institut fuer Festkoerperphysik, Friedrich-Schiller-Universitaet Jena (Germany); Ye, Jian; Ulrich, Sven [Institut fuer Materialforschung, Forschungszentrum Karlsruhe (Germany)

    2011-07-01

    Cubic boron nitride (cBN) is the hardest materials beneath diamond and exceeds the properties in terms of chemical resistivity, making it a promising candidate for ultra-hard coatings in extreme environments. Due to the ion assisted growth process, the cBN layers suffer from an intrinsic stress, which limits the layer thickness and therefore possible industrial applications. To investigate new approaches for the synthesis of low stress cBN layers, we applied ion irradiation with various ion species (O,Ne,Kr) and at different temperatures between 300 to 600 K to cBN:O layers. The intrinsic stress and the cBN content were monitored by profilometer and FTIR after each implantation step. As expected, ion irradiation at room temperature leads to a stress reduction with constant cBN content upon an ion induced damage up to 0.5 dpa, but a severe damage is introduced to the layer above this value resulting into a phase transition to hBN. However, irradiation at elevated temperatures results in a significant stress reduction without decrease of the cBN quality even up to 4.3 dpa.

  19. Timeframe Dependent Fragment Ions Observed in In-Source Decay Experiments with β-Casein Using MALDI MS

    Science.gov (United States)

    Sekiya, Sadanori; Nagoshi, Keishiro; Iwamoto, Shinichi; Tanaka, Koichi; Takayama, Mitsuo

    2015-09-01

    The fragment ions observed with time-of-flight (TOF) and quadrupole ion trap (QIT) TOF mass spectrometers (MS) combined with matrix-assisted laser desorption/ionization in-source decay (MALDI-ISD) experiments of phosphorylated analytes β-casein and its model peptide were compared from the standpoint of the residence timeframe of analyte and fragment ions in the MALDI ion source and QIT cell. The QIT-TOF MS gave fragment c-, z'-, z-ANL, y-, and b-ions, and further degraded fragments originating from the loss of neutrals such as H2O, NH3, CH2O (from serine), C2H4O (from threonine), and H3PO4, whereas the TOF MS merely showed MALDI source-generated fragment c-, z'-, z-ANL, y-, and w-ions. The fragment ions observed in the QIT-TOF MS could be explained by the injection of the source-generated ions into the QIT cell or a cooperative effect of a little internal energy deposition, a long residence timeframe (140 ms) in the QIT cell, and specific amino acid effects on low-energy CID, whereas the source-generated fragments (c-, z'-, z-ANL, y-, and w-ions) could be a result of prompt radical-initiated fragmentation of hydrogen-abundant radical ions [M + H + H]+ and [M + H - H]- within the 53 ns timeframe, which corresponds to the delayed extraction time. The further degraded fragment b/y-ions produced in the QIT cell were confirmed by positive- and negative-ion low-energy CID experiments performed on the source-generated ions (c-, z'-, and y-ions). The loss of phosphoric acid (98 u) from analyte and fragment ions can be explained by a slow ergodic fragmentation independent of positive and negative charges.

  20. Damage accumulation in MgO irradiated with MeV Au ions at elevated temperatures

    Energy Technology Data Exchange (ETDEWEB)

    Bachiller-Perea, Diana, E-mail: dianabachillerperea@gmail.com [Centre de Sciences Nucléaires et de Sciences de la Matière (CSNSM), Univ. Paris-Sud, CNRS-IN2P3, Université Paris-Saclay, 91405, Orsay Cedex (France); Centro de Micro-Análisis de Materiales, Universidad Autónoma de Madrid, C/Faraday 3, 28049, Madrid (Spain); Dpto. de Física Aplicada, Universidad Autónoma de Madrid, Ciudad Universitaria de Cantoblanco, 28049, Madrid (Spain); Debelle, Aurélien, E-mail: aurelien.debelle@u-psud.fr [Centre de Sciences Nucléaires et de Sciences de la Matière (CSNSM), Univ. Paris-Sud, CNRS-IN2P3, Université Paris-Saclay, 91405, Orsay Cedex (France); Thomé, Lionel [Centre de Sciences Nucléaires et de Sciences de la Matière (CSNSM), Univ. Paris-Sud, CNRS-IN2P3, Université Paris-Saclay, 91405, Orsay Cedex (France); Behar, Moni [Instituto de Física, Universidade Federal do Rio Grande do Sul, C.P. 15051, 91501-970, Porto Alegre, RS (Brazil)

    2016-09-15

    The damage accumulation process in MgO single crystals under medium-energy heavy ion irradiation (1.2 MeV Au) at fluences up to 4 × 10{sup 14} cm{sup −2} has been studied at three different temperatures: 573, 773, and 1073 K. Disorder depth profiles have been determined through the use of the Rutherford backscattering spectrometry in channeling configuration (RBS/C). The analysis of the RBS/C data reveals two steps in the MgO damage process, irrespective of the temperature. However, we find that for increasing irradiation temperature, the damage level decreases and the fluence at which the second step takes place increases. A shift of the damage peak at increasing fluence is observed for the three temperatures, although the position of the peak depends on the temperature. These results can be explained by an enhanced defect mobility which facilitates defect migration and may favor defect annealing. X-ray diffraction reciprocal space maps confirm the results obtained with the RBS/C technique. - Highlights: • High-temperature MeV-ion irradiated MgO exhibits a two-step damage process. • The occurrence of the second step is delayed with increasing temperature. • The damage level decreases with increasing temperature. • A shift of the damage peak is observed with increasing fluence. • A high defect mobility at high temperatures in MgO is clearly evidenced.