WorldWideScience

Sample records for temperature 0400-1000 k

  1. Plastic behaviour of Zircaloy-4 in the temperature range 77-1000 K

    International Nuclear Information System (INIS)

    Derep, J.L.; Ibrahim, S.; Rouby, D.; Fantozzi, G.; Gobin, P.

    1979-01-01

    Tensile tests were carried out on Zircaloy-4 over a temperature range 77-1000 K. So, we have determined the flow stress variations as a function of temperature and strain rate. Two thermally activated zones were observed between about 77 and 600 K, a plateau stress between 600 and 700 K and an other thermally activated zone above 700 K. The various mechanisms which can be responsible for the thermally activated and athermal zones are discussed in the light of experimental results. The mechanical behaviour of Zircaloy-4 appears similar to the zirconium-oxygen alloys one. (orig.) [de

  2. Reply to "On Vaporization of liquid Pb-Li eutectic alloy from 1000 K to 1200 K- A high temperature mass spectrometric study"

    Science.gov (United States)

    Jain, Uttam; Mukherjee, Abhishek

    2018-03-01

    This communication is in response to a letter to editor commenting on the authors' earlier paper "Vaporization of liquid Pb-Li eutectic alloy from 1000 K to 1200 K - A high temperature mass spectrometric study".

  3. Exon: CBRC-RNOR-01-0400 [SEVENS

    Lifescience Database Archive (English)

    Full Text Available CBRC-RNOR-01-0400 ctccgaaaaaaagaaccaaaaaaaaaaaaaaaaaaaaaaaaaaaaaacctatgtacaaaagcctg...gtgtggtggtgcacacttgtattatcagcatgggggagcagaggcaagctgatccctgggacctgctagcccacttaacaagtttcaggccagtgatagactgtttcaaa

  4. ASD-1000: High-resolution, high-temperature acetylene spectroscopic databank

    Science.gov (United States)

    Lyulin, O. M.; Perevalov, V. I.

    2017-11-01

    We present a high-resolution, high-temperature version of the Acetylene Spectroscopic Databank called ASD-1000. The databank contains the line parameters (position, intensity, Einstein coefficient for spontaneous emission, term value of the lower states, self- and air-broadening coefficients, temperature dependence exponents of the self- and air-broadening coefficients) of the principal isotopologue of C2H2. The reference temperature for line intensity is 296 K and the intensity cutoff is 10-27 cm-1/(molecule cm-2) at 1000 K. The databank has 33,890,981 entries and covers the 3-10,000 cm-1 spectral range. The databank is based on the global modeling of the line positions and intensities performed within the framework of the method of effective operators. The parameters of the effective Hamiltonian and the effective dipole moment operator have been fitted to the observed values of the line positions and intensities collected from the literature. The broadening coefficients as well as their temperature dependence exponents were calculated using the empirical equations. The databank is useful for studying high-temperature radiative properties of C2H2. ASD-1000 is freely accessible via the Internet site of V.E. Zuev Institute of Atmospheric Optics SB RAS ftp://ftp.iao.ru/pub/ASD1000/.

  5. Germanium thermometers in the temperature range .1000K to 4.20K

    International Nuclear Information System (INIS)

    Hsieh, S.Y.; Sanchez, D.H.

    1974-01-01

    The sensitivity characteristics of two germanium thermometers that proved to be convenient sensors in the temperature range from .100 0 K to 4.2 0 K, are described. Their resistances change from about 8 x 10 5 ohms at .100 0 K to about 100 ohms at 4.2 0 K. The calibration curves were fitted to natural spline functions of order 3 in the whole range of temperatures. These functions give less than half millidegree standard dispersion against 15 millidegree standard dispersion when usual polynomial interpolations are used. It is discussed what spline functions are, and compare the goodness of spline interpolation with polynomial methods [pt

  6. Fluoride salts as phase change materials for thermal energy storage in the temperature range 1000-1400 K

    Science.gov (United States)

    Misra, Ajay K.

    1988-01-01

    Eutectic compositions and congruently melting intermediate compounds in binary and ternary fluoride salt systems were characterized for potential use as latent heat of fusion phase change materials to store thermal energy in the temperature range 1000-1400 K. The melting points and eutectic compositions for many systems with published phase diagrams were experimentally verified and new eutectic compositions having melting points between 1000 and 1400 K were identified. Heats of fusion of several binary and ternary eutectics and congruently melting compounds were experimentally measured by differential scanning calorimetry. For a few systems in which heats of mixing in the melts have been measured, heats of fusion of the eutectics were calculated from thermodynamic considerations and good agreement was obtained between the measured and calculated values. Several combinations of salts with high heats of fusion per unit mass (greater than 0.7 kJ/g) have been identified for possible use as phase change materials in advanced solar dynamic space power applications.

  7. Lattice parameters and thermal expansion of delta-VNsub(1-x) from 298-1000 K

    International Nuclear Information System (INIS)

    Lengauer, W.; Ettmayer, P.

    1986-01-01

    The thermal expansion of VNsub(1-x) was determined from measurements of the lattice parameters in the temperature range of 298-1000 K and in the composition range of VNsub(0.707) - VNsub(0.996). Within the accuracy of the results the expansion of the lattice parameter with temperature is not dependent on the composition. The lattice parameter as a function of composition ([N]/[V] = 0.707-0.996) and temperature (198-1000 K) is given by a([N]/[V], T) = 0.38872+0.02488 ([N]/[V]) - (1.083+-0.021) x 10 -4 Tsup(1/2) + (6.2+-0.1) x 10 - sup6T. The coefficient of linear thermal expansion as a function of temperature (in the same range) is given by α(T) = a([N]/[V], T) -1 [(-5.04+-0.01) x 10 -5 Tsup(1/2) + (6.2+-0.1) x 10 -6 ]. The average linear thermal expansion coefficient is αsub(av) = 9.70 +- 0.15 x 10 -6 K -1 (298-1000 K). The data are compared with those of several fcc transition metal nitrides collected and evaluated from the literature. (Author)

  8. Reaction Dynamics of CH{sub 3} + HBr → CH{sub 4} + Br at 150-1000 K

    Energy Technology Data Exchange (ETDEWEB)

    Ree, Jongbaik [Chonnam National Univ., Gwangju (Korea, Republic of); Kim, Yoo Hang [Inha Univ., Incheon (Korea, Republic of); Shin, Hyung Kyu [Univ. of Nevado, Nevado (United States)

    2013-08-15

    The kinetics of the radical-polar molecule reaction CH{sub 3} + HBr → CH{sub 4} + Br has been studied at temperatures between 150 and 1000 K using classical dynamics procedures. Potential energy surfaces constructed using analytical forms of inter- and intramolecular interaction energies show a shallow well and barrier in the entrance channel, which affect the collision dynamics at low temperatures. Different collision models are used to distinguish the reaction occurring at low- and high-temperature regions. The reaction proceeds rapidly via a complex-mode mechanism below room temperature showing strong negative temperature dependence, where the effects of molecular attraction, H-atom tunneling and recrossing of collision complexes are found to be important. The temperature dependence of the rate constant between 400 and 1000 K is positive, the values increasing in accordance with the increase of the mean speed of collision. The rate constant varies from 7.6 Χ 10{sup -12} at 150 K to 3.7 Χ 10{sup -12} at 1000 K via a minimum value of 2.5 Χ 10{sup -12} cm{sup 3} molecule{sup -1} s{sup -1} at 400 K.

  9. Thermal conduction and linear expansion of sintered rhenium and tungsten-rhenium alloys at a temperature up to 1000 K

    International Nuclear Information System (INIS)

    Pozdnyak, N.Z.; Belyaev, R.A.; Vavilov, Yu.V.; Vinogradov, Yu.G.; Serykh, G.M.

    1978-01-01

    Preparation technology (by powder metallurgy methods) of sintered rhenium and tungsten-rhenium VR-5, VR-10, and VR-20 alloys is described. Thermal conduction of rhenium and VR-20 alloy has been measured in the temperature range from 300 to 1000 K. The value obtained turned out to be considerably less than those published elsewhere, this testifies to the great thermal contact resistance between the material grains. Also measured is the mean linear expansion coefficient for the mentioned above materials in the same temperature range. Linear expansion increases with rhenium content increase

  10. Thermal desorption spectroscopy of pyrolytic graphite cleavage faces after keV deuterium irradiation at 330-1000 K

    International Nuclear Information System (INIS)

    Gotoh, Y.; Yamaki, T.; Tokiguchi, K.

    1992-01-01

    Thermal desorption spectroscopy (TDS) measurements were made on D 2 and CD 4 from surface layers of pyrolytic graphite cleavage faces after 3 keV D + 3 irradiation to 1.5 x 10 18 D/cm 2 at irradiation temperatures from 330 to 1000 K. Thermal desorption of both D 2 and CD 4 was observed to rise simultaneously at around 700 K. The D 2 peak was found at T m = 900-1000 K, while the CD 4 peak appeared at a lower temperature, 800-840 K. The T m for the D 2 TDS increased, while that for the CD 4 decreased with increasing irradiation temperature. These results obviously indicate that the D 2 desorption is detrapping/recombination limited, while the CD 4 desorption is most likely to be diffusion limited. The amount of thermally desorbed D 2 after the D + irradiation was observed to monotonously decrease as the irradiation temperature was increased from 330 to 1000 K. These tendencies agreed with previous results for the irradiation temperature dependencies of both C1s chemical shift (XPS) and the interlayer spacing, d 002 (HRTEM), on the graphite basal face. (orig.)

  11. Diurnal, seasonal and latitudinal variations of electron temperature measured by the SROSS C2 satellite at 500 km altitude and comparison with the IRI

    Directory of Open Access Journals (Sweden)

    P. K. Bhuyan

    2002-06-01

    Full Text Available The diurnal, seasonal and latitudinal variations of electron temperature Te, measured by the SROSS C2 satellite at equatorial and the low-latitudes during the low solar activity period of 1995–1997 are investigated. The average height of the satellite was ~ 500 km and it covered the latitude belt of –31° to 34° and the longitude range of 40°–100°. Te varies between 700–800 K during night-time (20:00–04:00 LT, rises sharply during sunrise (04:00–06:00 LT to reach a level of ~ 3500 K within a couple of hours and then falls between 07:00–10:00 LT to a daytime average value of ~ 1600 K. A secondary maximum is observed around 16:00–18:00 LT in summer. Latitudinal gradients in Te have been observed during the morning enhancement and daytime hours. Comparison of measured and International Reference Ionosphere (IRI predicted electron temperature reveals that the IRI predicts nighttime Te well within ~ 100 K of observation, but at other local times, the predicted Te is less than that measured in all seasons.Key words. Ionosphere, equatorial ionosphere, plasma temperature, and density

  12. 4H-SiC JFET Multilayer Integrated Circuit Technologies Tested Up to 1000 K

    Science.gov (United States)

    Spry, D. J.; Neudeck, P. G.; Chen, L.; Chang, C. W.; Lukco, D.; Beheim, G. M.

    2015-01-01

    Testing of semiconductor electronics at temperatures above their designed operating envelope is recognized as vital to qualification and lifetime prediction of circuits. This work describes the high temperature electrical testing of prototype 4H silicon carbide (SiC) junction field effect transistor (JFET) integrated circuits (ICs) technology implemented with multilayer interconnects; these ICs are intended for prolonged operation at temperatures up to 773K (500 C). A 50 mm diameter sapphire wafer was used in place of the standard NASA packaging for this experiment. Testing was carried out between 300K (27 C) and 1150K (877 C) with successful electrical operation of all devices observed up to 1000K (727 C).

  13. Low cycle fatigue behavior of polycrystalline NiAl at 300 and 1000 K

    Science.gov (United States)

    Lerch, Bradley A.; Noebe, Ronald D.

    1993-01-01

    The low cycle fatigue behavior of polycrystalline NiAl was determined at 300 and 1000 K - temperatures below and above the brittle- to-ductile transition temperature (BDTT). Fully reversed, plastic strain-controlled fatigue tests were conducted on two differently fabricated alloy samples: hot isostatically pressed (HIP'ed) prealloyed powder and hot extruded castings. HIP'ed powder (HP) samples were tested only at 1000 K, whereas the more ductile cast-and-extruded (C+E) NiAl samples were tested at both 1000 and 300 K. Plastic strain ranges of 0.06 to 0.2 percent were used. The C+E NiAl cyclically hardened until fracture, reaching stress levels approximately 60 percent greater than the ultimate tensile strength of the alloy. Compared on a strain basis, NiAl had a much longer fatigue life than other B2 ordered compounds in which fracture initiated at processing-related defects. These defects controlled fatigue life at 300 K, with fracture occurring rapidly once a critical stress level was reached. At 1000 K, above the BDTT, both the C+E and HP samples cyclically softened during most of the fatigue tests in air and were insensitive to processing defects. The processing method did not have a major effect on fatigue life; the lives of the HP samples were about a factor of three shorter than the C+E NiAl, but this was attributed to the lower stress response of the C+E material. The C+E NiAl underwent dynamic grain growth, whereas the HP material maintained a constant grain size during testing. In both materials, fatigue life was controlled by intergranular cavitation and creep processes, which led to fatigue crack growth that was primarily intergranular in nature. Final fracture by overload was transgranular in nature. Also, HP samples tested in vacuum had a life three times longer than their counterparts tested in air and, in contrast to those tested in air, hardened continuously over half of the sample life, thereby indicating an environmentally assisted fatigue damage

  14. SEA0400 fails to alter the magnitude of intracellular Ca2+ transients and contractions in Langendorff-perfused guinea pig heart.

    Science.gov (United States)

    Szentandrássy, Norbert; Birinyi, Péter; Szigeti, Gyula; Farkas, Attila; Magyar, János; Tóth, András; Csernoch, László; Varró, András; Nánási, Péter P

    2008-07-01

    SEA0400 is a recently developed inhibitor of the Na+/Ca2+ exchanger (NCX) shown to suppress both forward and reverse mode operation of NCX. Present experiments were designed to study the effect of partial blockade of NCX on Ca handling and contractility in Langendorff-perfused guinea pig hearts loaded with the fluorescent Ca-sensitive dye fura-2. Left ventricular pressure and intracellular calcium concentration ([Ca2+]i) were synchronously recorded before and after cumulative superfusion with 0.3 and 1 muM SEA0400. SEA0400 caused no significant change in the systolic and diastolic values of left ventricular pressure and [Ca2+]i. Accordingly, pulse pressure and amplitude of the [Ca2+]i transient also remained unchanged in the presence of SEA0400. SEA0400 had no influence either on the time required to reach peak values of pressure and [Ca2+)]i or on half relaxation time. On the other hand, both 0.3 and 1 microM SEA0400 significantly increased the decay time constant of [Ca2+]i transients, obtained by fitting its descending limb between 30% and 90% of relaxation, from 127 +/- 7 to 165 +/- 7 and 177 +/- 14 ms, respectively (P hearts, rat hearts responded to SEA0400 treatment with increased [Ca2+]i transients and contractility. These interspecies differences observed in the effect of SEA0400 can be explained by the known differences in calcium handling between the two species.

  15. High-purity metal-carbon eutectic systems as thermometric fixed points in the range from 1000 K to 3500 K; Des systemes eutectiques metal-carbone de grande purete comme points fixes de temperature dans l'intervalle 1000-3500 K

    Energy Technology Data Exchange (ETDEWEB)

    Bloembergen, P.; Yamada, Y.; Sasajima, N.; Yamamoto, N. [National Metrology Institute of Japan (NMIJ), AIST, Tsukuba (Japan); Torizuka, S.; Yoshida, N. [National Institute for Materials Science (NIMS), Tsukuba (Japan)

    2004-12-01

    A survey will be given of metal-carbon (M-C) and metal carbide-carbon (MC-C) systems presently in development for applications in thermometry in the range from 1000 K to about 3500 K. The advantages of these systems as fixed points at high temperatures as compared to systems relying on pure metals will be elucidated. Purification of the components making up the M-C or MC-C systems is a prerequisite to their implementation as reference fixed points in thermometry, requiring a high level of reproducibility of the eutectic temperature. To set an example a study on the effect of impurities on the eutectic transition of Fe-C is included in the survey. Experimentally obtained melting curves are compared with the curves calculated on the basis of a thermodynamic model, which includes the impurities in question as components. The calculations of the melting curves are based upon: (1) the Equilibrium solidification model and (2) the Scheil-Gulliver solidification model, which handle the effects of the impurities on the transition process in such a way that they may be assumed to set lower and upper boundaries to the associated melting ranges, respectively. We will conclude pointing out fields of common interest to materials science and thermometry within the realm of ultra-pure materials. (authors)

  16. Study of robust thin film PT-1000 temperature sensors for cryogenic process control applications

    Science.gov (United States)

    Ramalingam, R.; Boguhn, D.; Fillinger, H.; Schlachter, S. I.; Süßer, M.

    2014-01-01

    In some cryogenic process measurement applications, for example, in hydrogen technology and in high temperature superconductor based generators, there is a need of robust temperature sensors. These sensors should be able to measure the large temperature range of 20 - 500 K with reasonable resolution and accuracy. Thin film PT 1000 sensors could be a choice to cover this large temperature range. Twenty one sensors selected from the same production batch were tested for their temperature sensitivity which was then compared with different batch sensors. Furthermore, the sensor's stability was studied by subjecting the sensors to repeated temperature cycles of 78-525 K. Deviations in the resistance were investigated using ice point calibration and water triple point calibration methods. Also the study of directional oriented intense static magnetic field effects up to 8 Oersted (Oe) were conducted to understand its magneto resistance behaviour in the cryogenic temperature range from 77 K - 15 K. This paper reports all investigation results in detail.

  17. Study of nitrogen solubility in multicomponent iron alloys at its pressure in gaseous phase up to 1000kPa

    International Nuclear Information System (INIS)

    Pomarin, Yu.M.; Grigorenko, G.M.; Latash, Yu.V.; Kanibolotskij, S.A.

    1983-01-01

    A facility in which metal is melted in a weighed state and nitrogen partical pressure during relting may be charge from 0 to 1000 kPa is developed to investigate nitrogen solubility is liquim metals and alloys. Investigation of nitrogen solubility was performed using samples of 03Kh25N5AM3 steel and Kh20N5, Kh20N10, Kh40N10, Kh40N20 alloys. Positive deflection of [N]=f(√Psub(Nsub(2))) dependence from the Henry law is shown to be observed in the Kh40N10 alloy in the 100-1000 kPa pressure range. In this case the vatue of positive deflection decreases with temperature growth and at T=2273 K nitrogen solubility in the alloy submits to the law of square root. An equation permitting to calculate nitrogen solubility in alloys of Fe-Cr-Ni and Fe-Cr-Mn systems in the 0 to 1000 kPa range of nitrogen partial pressures is obtained

  18. An automated thermal relaxation calorimeter for operation at low temperature (0.5KK)

    International Nuclear Information System (INIS)

    Banerjee, S.; Prins, M.W.J.; Rajeev, K.P.; Raychaudhuri, A.K.

    1992-01-01

    An automated calorimeter for measurement of specific heat in the temperature range 10K>T>0.5K. It uses sample of moderate size (100-1000 mg), has a moderate precision and accuracy (2%-5%) is easy to operate and the measurements can be done quickly with 3 He economy is described. The accuracy of this calorimeter was checked by measurement of specific heat of copper and that of aluminium near its superconducting transition temperature. (author). 12 refs., 11 figs

  19. Mechanisms of radiation embrittlement of VVER-1000 RPV steel at irradiation temperatures of (50–400)°C

    Energy Technology Data Exchange (ETDEWEB)

    Kuleshova, E.A., E-mail: evgenia-orm@yandex.ru [National Research Center “Kurchatov Institute”, Kurchatov Sq. 1, Moscow 123182 (Russian Federation); National Research Nuclear University “MEPhI” (Moscow Engineering Physics Institute), Kashirskoe Highway 31, Moscow 115409 (Russian Federation); Gurovich, B.A.; Bukina, Z.V.; Frolov, A.S.; Maltsev, D.A.; Krikun, E.V.; Zhurko, D.A.; Zhuchkov, G.M. [National Research Center “Kurchatov Institute”, Kurchatov Sq. 1, Moscow 123182 (Russian Federation)

    2017-07-15

    This work summarizes and analyzes our recent research results on the effect of irradiation temperature within the range of (50–400)°C on microstructure and properties of 15Kh2NMFAA class 1 steel (VVER-1000 reactor pressure vessel (RPV) base metal). The paper considers the influence of accelerated irradiation with different temperature up to different fluences on the carbide and irradiation-induced phases, radiation defects, yield strength changes and critical brittleness temperature shift (ΔT{sub K}) as well as on changes of the fraction of brittle intergranular fracture and segregation processes in the steel. Low temperature irradiation resulted solely in formation of radiation defects – dislocation loops of high number density, the latter increased with increase in irradiation temperature while their size decreased. In this regard high embrittlement rate observed at low temperature irradiation is only due to the hardening mechanism of radiation embrittlement. Accelerated irradiation at VVER-1000 RPV operating temperature (∼300 °C) caused formation of radiation-induced precipitates and dislocation loops, as well as some increase in phosphorus grain boundary segregation. The observed ΔT{sub K} shift being within the regulatory curve for VVER-1000 RPV base metal is due to both hardening and non-hardening mechanisms of radiation embrittlement. Irradiation at elevated temperature caused more intense phosphorus grain boundary segregation, but no formation of radiation-induced precipitates or dislocation loops in contrast to irradiation at 300 °C. Carbide transformations observed only after irradiation at 400 °C caused increase in yield strength and, along with a contribution of the non-hardening mechanism, resulted in the lowest ΔT{sub K} shift in the studied range of irradiation temperature and fluence. - Highlights: •Structural elements in RPV steel are studied at different irradiation temperatures. •Highest number density dislocation loops are

  20. Isothermal Reaction of NiO Powder with Undiluted CH4 at 1000 K to 1300 K (727 °C to 1027 °C)

    Science.gov (United States)

    Altay, Melek Cumbul; Eroglu, Serafettin

    2017-08-01

    In this study, isothermal reaction behavior of loose NiO powder in a flowing undiluted CH4 atmosphere at the temperature range 1000 K to 1300 K (727 °C to 1027 °C) is investigated. Thermodynamic analyses at this temperature range revealed that single phase Ni forms at the input n_{CH}_{4}^{o} + n_{NiO}^{o}) (n_{CH}_{4}^{{o} + n_{NiO}^{o}) mole fractions ( X_{CH}_{4} ) between 0.2 and 0.5. It was also predicted that free C co-exists with Ni at X_{{{{CH}}_{ 4} }} values higher than 0.5. The experiments were carried out as a function of temperature, time, and CH4 flow rate. Mass measurement, XRD and SEM-EDX were used to characterize the products at various stages of the reaction. At 1200 K and 1300 K (927 °C and 1027 °C), the reaction of NiO with undiluted CH4 essentially consisted of two successive distinct stages: NiO reduction and pyrolytic C deposition on pre-reduced Ni particles. At 1200 K (927 °C), 1100 K (827 °C), and 1000 K (727 °C), complete oxide reduction was observed within 7.5, 17.5, and 45 minutes, respectively. It was suggested that NiO was essentially reduced to Ni by a CH4 decomposition product, H2. Possible reactions leading to NiO reduction were suggested. An attempt was made to describe the NiO reduction kinetics using nucleation-growth and geometrical contraction models. It was observed that the extent of NiO reduction and free C deposition increased with the square root of CH4 flow rate as predicted by a mass transport theory. A mixed controlling mechanism, partly chemical kinetics and partly external gaseous mass transfer, was responsible for the overall reaction rate. The present study demonstrated that the extent of the reduction can be determined quantitatively using the XRD patterns and also using a formula theoretically derived from the basic XRD data.

  1. 1000kW on-site PAFC power plant development and demonstration

    Energy Technology Data Exchange (ETDEWEB)

    Satomi, Tomohide; Koike, Shunichi [Phosphoric Acid Fuel Cell Technology Research Association (PAFC-TRA), Osaka (Japan); Ishikawa, Ryou [New Energy and Industrial Technology Development Organization (NEDO), Tokyo (Japan)

    1996-12-31

    Phosphoric Acid Fuel Cell Technology Research Association (PAFC-TRA) and New Energy and Industrial Technology Development Organization (NEDO) have been conducting a joint project on development of a 5000kW urban energy center type PAFC power plant (pressurized) and a 1000kW on-site PAFC power plant (non-pressurized). The objective of the technical development of 1000kW on-site PAFC power plant is to realize a medium size power plant with an overall efficiency of over 70% and an electrical efficiency of over 36%, that could be installed in a large building as a cogeneration system. The components and system integration development work and the plant design were performed in 1991 and 1992. Manufacturing of the plant and installation at the test site were completed in 1994. PAC test was carried out in 1994, and generation test was started in January 1995. Demonstration test is scheduled for 1995 and 1996.

  2. Young's modulus of crystal bar zirconium and zirconium alloys (zircaloy-2, zircaloy-4, zirconium-2.5wt% niobium) to 1000 K

    International Nuclear Information System (INIS)

    Rosinger, H.E.; Ritchie, I.G.; Shillinglaw, A.J.

    1975-09-01

    This report contains experimentally determined data on the dynamic elastic moduli of zircaloy-2, zircaloy-4, zirconium-2.5wt% niobium and Marz grade crystal bar zirconium. Data on both the dynamic Young's moduli and shear moduli of the alloys have been measured at room temperature and Young's modulus as a function of temperature has been determined over the temperature range 300 K to 1000 K. In every case, Young's modulus decreases linearly with increasing temperature and is expressed by an empirical equation fitted to the data. Differences in Young's modulus values determined from specimens with longitudinal axes parallel and perpendicular to the rolling direction are small, as are the differences between Young's moduli determined from strip, bar stock and fuel sheathing. (author)

  3. Thermal aging effects of VVER-1000 weld metal under operation temperature

    International Nuclear Information System (INIS)

    Chernobaeva, A.A.; Kuleshova, E.A.; Gurovich, B.A.; Erak, D.Y.; Zabusov, O.O.; Maltsev, D.A.; Zhurko, D.A.; Papina, V.B.; Skundin, M.A.

    2015-01-01

    The VVER-1000 thermal aging surveillance specimen sets are located in the reactor pressure vessel (RPV) under real operation conditions. Thermal aging surveillance specimens data are the most reliable source of the information about changing of VVER-1000 RPV materials properties because of long-term (hundred thousand hours) exposure at operation temperature. A revision of database of VVER-1000 weld metal thermal aging surveillance specimens has been done. The reassessment of transition temperature (T t ) for all tested groups of specimens has been performed. The duration of thermal exposure and phosphorus contents have been defined more precisely. The analysis of thermal aging effects has been done. The yield strength data, study of carbides evolution show absence of hardening effects due to thermal aging under 310-320 C degrees. Measurements of phosphorus content in grain boundaries segregation in different states have been performed. The correlation between intergranular fracture mode in Charpy specimens and transition temperature shift under thermal aging at temperature 310-320 C degrees has been revealed. All these data allow developing the model of thermal aging. (authors)

  4. 1000 kW ICRH amplifiers for MFTF-B

    International Nuclear Information System (INIS)

    Boksberger, U.

    1986-01-01

    For the startup of the MFTF-B ICRH heating will be applied. Two commercial amplifiers derived from standard broadcast transmitters provide 1000 kW RF power each into a matching system for any VSWR as high as 1.5. Emphasis is put on the specific environment of magnetic fields and seismic loads as well as to the particular RF power control requirements and remote operation. Also addressed is the amplifier's performance into a typical load. The load variations due to the MFTF-B plasma coupling were calculated by TRW

  5. Vaporization of liquid Pb-Li eutectic alloy from 1000K to 1200K - A high temperature mass spectrometric study

    Science.gov (United States)

    Jain, U.; Mukherjee, A.; Dey, G. K.

    2017-09-01

    Liquid lead-lithium eutectic will be used as a coolant in fusion reactor blanket loop. Vapor pressure of the eutectic is an important parameter to accurately predict its in-loop behavior. Past measurements of vapor pressure of the eutectic relied on indirect methods. In this paper, we report for the first time the in-situ vaporization behavior of the liquid alloy between 1042 and 1176 K by Knudsen effusion mass spectrometry (KEMS). It was seen that the vaporization occurred by independent evaporation of lead and lithium. No complex intermetallic vapor was seen in the mass spectra. The partial pressures and enthalpy of vaporization of Pb and Li were evaluated directly from the measured ion intensities formed from the equilibrium vapor over the alloy. The activity of Li over a temperature range of 1042-1176 K was found to be 4.8 × 10-5 to that of pure Li, indicating its very low activity in the alloy.

  6. 1000 Hours of Testing Completed on 10-kW Hall Thruster

    Science.gov (United States)

    Mason, Lee S.

    2001-01-01

    Between the months of April and August 2000, a 10-kW Hall effect thruster, designated T- 220, was subjected to a 1000-hr life test evaluation. Hall effect thrusters are propulsion devices that electrostatically accelerate xenon ions to produce thrust. Hall effect propulsion has been in development for many years, and low-power devices (1.35 kW) have been used in space for satellite orbit maintenance. The T-220, shown in the photo, produces sufficient thrust to enable efficient orbital transfers, saving hundreds of kilograms in propellant over conventional chemical propulsion systems. This test is the longest operation ever achieved on a high-power Hall thruster (greater than 4.5 kW) and is a key milestone leading to the use of this technology for future NASA, commercial, and military missions.

  7. Ab initio molecular dynamics study of the properties of cerium in liquid sodium at 1000K temperature

    Energy Technology Data Exchange (ETDEWEB)

    Samin, Adib; Li, Xiang; Zhang, Jinsuo [Nuclear Engineering Program, Department of Mechanical and Aerospace Engineering, The Ohio State University, 201 W 19th Avenue, Columbus, Ohio 43210 (United States); Mariani, R. D. [Idaho National Laboratory, Materials and Fuels Complex, Idaho Falls, Idaho 83415 (United States); Unal, Cetin [Los Alamos National Laboratory, P.O. Box 1663, Los Alamos, New Mexico 87545 (United States)

    2015-12-21

    For liquid-sodium-cooled fast nuclear reactor systems, it is crucial to understand the behavior of lanthanides and other potential fission products in liquid sodium or other liquid metal solutions such as liquid cesium-sodium. In this study, we focus on lanthanide behavior in liquid sodium. Using ab initio molecular dynamics, we found that the solubility of cerium in liquid sodium at 1000K was less than 0.78 at. %, and the diffusion coefficient of cerium in liquid sodium was calculated to be 5.57 × 10{sup −9} m{sup 2}/s. Furthermore, it was found that cerium in small amounts may significantly alter the heat capacity of the liquid sodium system. Our results are consistent with the experimental results for similar materials under similar conditions.

  8. Nb/sub 3/Al formation at temperatures lower than 1000/sup 0/C. [J/sub c/ and T/sub c/

    Energy Technology Data Exchange (ETDEWEB)

    Ceresara, S. (ISML, Novara, Italy); Ricci, M.V.; Sacchetti, N.; Sacerdoti, G.

    1975-03-01

    A study was made of the possibility of making Nb/sub 3/Al wires by interdiffusion between Al and Nb at relatively low temperatures (lower than 1000/sup 0/C). This method should allow the fabrication of a copper stabilized wire by coworking Nb and Al composites in a copper matrix before the diffusion treatment. Results concerning the diffusion temperature and time dependence of J/sub c/ and T/sub c/ are presented. While J/sub c/(64 kG) is quite high, of the order of 1.5 x 10/sup 5/ A/cm/sup 2/, T/sub c/ is 15.56/sup 0/K, lower than the usually reported value. X-ray measurements of the lattice parameter are also reported and correlated with the measured value of T/sub c/.

  9. 1000-kVA arc power supply

    International Nuclear Information System (INIS)

    Wright, R.E.; Barber, G.C.; Ponte, N.S.

    1979-01-01

    Because of ever-increasing power demands for the development of the Oak Ridge duoPIGatron ion source, a continuous-duty arc power supply was constructed for the Medium Energy Test Facility (METF) to furnish power for the plasma generator of experimental ion sources. The power supply utilizes 12-pulse rectification with half-wave switching in a delta and wye full-wave bridge that may be connected in series or parallel. It will deliver 340 V dc, 2500 A to an ion source when series connected and 170 V dc, 5000 A when paralleled connected. Silicon-controlled rectifiers (SCR) in each rectifier bridge can be switched for pulses as short as 10 ms through continuous duty. The filter section that reduces the ripple in the output consists of an inductor-to-capacitor (L-C) filter to smooth the 720-Hz pulses. The power transformer serves as an isolation transformer allowing the secondary to be elevated to the accelerating potential of the ion source. The dc output level is controlled with a 1000-kVA auto transformer connected to the primary of the power transformer. All elevated voltages and currents are monitored at ground potential with an optical telemetry system. This paper describes the power supply in detail, including block diagrams, component specifications, and waveforms when supplying power to an ion source

  10. Negative thermal expansion up to 1000 C of ZrTiO4-Al2TiO5 ceramics for high-temperature applications

    International Nuclear Information System (INIS)

    Kim, I.J.; Kim, H.C.; Han, I.S.; Aneziris, C.G.

    2005-01-01

    High temperature structural ceramics based on Al 2 TiO 5 -ZrTiO 4 (ZAT) having excellent thermal-shock-resistance were synthesized by a reaction sintering. The ZAT ceramics sintered at 1600 C had a negative thermal expansions up to 1000 C and a much lower thermal expansion coefficient (0.3 ∝ 1.3 x 10 -6 /K) than that of polycrystalline Al 2 TiO 5 (1.5 x 10 -6 /K). These low thermal expansion are apparently due to a combination of microcracking caused by the large thermal expansion anisotropy of the crystal axes of the Al 2 TiO 5 phase. The microstructural degradation of the composites after various thermal treatment for high temperature applications were analyzed by scanning electron microscopy, X-ray diffraction, ultrasonic and dilatometer. (orig.)

  11. Analysis of an accident with the main circulation tube rupture at the WWER-1000

    International Nuclear Information System (INIS)

    Boyadzhiev, A.I.; Stefanova, S.J.

    1984-01-01

    In connection with the forthcoming construction of a npp with the wwer-1000 reactor the loss of coolant accident associated with the main circulation tube rupture at the inlet near the reactor is analyzed. The relap4/mod6 program is used for the analysis. The data obtained show that the coolant outflow stage continues for about 25s. On the average the pressure in the circuits varies from 16 to 10 mpa per 0.1s and then it continues to decrease slowly. The pressure in the steam generator at the secondary circuits end increases approximately up to 6.9 MPa as a result of steam generator blocking and remaining coolant heating and then somewhat decreases owing to the primary circuit cooling. By the end of the fuel and can temperatures are equalized and the heat transfer coefficient is stabilized at the level of 100 w/1 (m 2 xK). It is concluded that during a loss of coolant accident at the wwer-1000 reactor in procesess of coolant blowdown in the medium power fuel elemets neither the fuel, melting temperature (3000 k), nor the critical temperature (1000 k) of plastic deformation zirconiu can initiation are attained

  12. SiO mass spectrometry and Si-2p photoemission spectroscopy for the study of oxidation reaction dynamics of Si(001) surface by supersonic O sub 2 molecular beams under 1000K

    CERN Document Server

    Teraoka, Y; Moritani, K

    2003-01-01

    The Si sup 1 sup 8 O desorption yield was measured in the Si(001) surface temperature region from 900K to 1300K at the sup 1 sup 8 O sub 2 incident energies of 0.7eV, 2.2eV and 3.3eV. The Si sup 1 sup 8 O desorption yield in a surface temperature region higher than 1000K increased with increasing incident energy, indicating the incident-energy-induced oxidation and the variation of angular distribution of Si sup 1 sup 8 O desorption. Inversely, the Si sup 1 sup 8 O desorption yield decreased with increasing incident energy in the region from 900K to 1000K, indicating the coexistence of the passive and the active oxidation. In order to clarify the reaction mechanisms of the later phenomenon, real-time in-situ Si-2p photoemission spectroscopy has been performed. The obtained Si-2p spectra showed the variation of the oxide-nuclei quality from the sub-oxide-rich structure to the SiO sub 2 -rich structure. The formation of the SiO sub 2 structure suppresses the SiO desorption due to the enhanced O sub 2 sticking a...

  13. Forced convection of ammonia. 2. part.: gaseous ammonia - very high wall temperatures (1000 to 3000 K); Convection forcee de l'ammoniac. 2. partie: ammoniac gazeux - cas de tres hautes temperatures de paroi (1000 a 3000{sup 0} K)

    Energy Technology Data Exchange (ETDEWEB)

    Perroud, P; Rebiere, J; Strittmatter, R [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1969-07-01

    Heat transfer coefficients and pressure drop of gaseous ammonia in forced convection are experimentally determined. The fluid flows (mass flow rate 0.6 to 2.4 g/s) in a long tungsten tube (d{sub i} = 2.8 mm, d{sub e} = 5.1 mm, L = 700 mm) electrically heated. The temperature of the wall reaches 3000 deg. K and the fluid 2500 deg. K; maximum heat flux 530 w/cm{sup 2}. Ammonia is completely dissociated and the power necessary for dissociation reaches 30 per cent of the total power exchanged. Inlet pressure varies between 6 and 16 bars and the maximum pressure drop in the tube reaches 15 bars. Two regimes of dissociation have been shown: catalytic and homogeneous and the variation of dissociation along the length of the tube is studied. The measured heat transfer coefficients may be about 10 times these calculated by the means of classical formulae. A correlation of experimental results using enthalpy as a driving force for heat transmission is presented. Pressure drops may be calculated by the means of a classical friction factor. (authors) [French] On determine experimentalement les coefficients d'echange thermique et les pertes de charge de l'ammoniac gazeux en convection forcee. Le fluide circule avec un debit en masse compris entre 0.6 et 2.4 g/s (G = 10 a 40 g/cm{sup 2}.s) dans un tube long en tungstene (d{sub i} = 2.8 mm, d{sub e} = 5.1 mm, L = 700 mm), chauffe electriquement. La temperature de paroi atteint 3000 deg. K, celle du fluide 2500 deg. K et le flux de chaleur maximal est de 530 W/cm{sup 2}. L'ammoniac se dissocie completement, la puissance correspondant a la dissociation atteint 30 pour cent de la puissance totale echangee. La pression d'entree varie entre 6 et 16 bars et la chute de pression maximale dans le canal est de 15 bars. On distingue deux regimes de dissociation, catalytique et homogene, et on etudie la variation du taux de dissociation en fonction de la longueur du tube. Les coefficients d'echange thermique mesures peuvent etre environ 10

  14. Comparison of technical and economical factors of 1000-MW steam turbines at 3000 and 1500 r.p.m. for nuclear power plants

    International Nuclear Information System (INIS)

    Markov, N.M.; Safonov, L.P.

    1980-01-01

    The problem of unification of the low-pressure cilinders (LPC) for turbo-generator units of nuclear power plants with power of 1000 MW on base of the WWER and RBMK type reactors is discussed. The results of the comparison of the K-1000-60/1500 and K-1000-60/3000 turbines in the thermal efficiency of flow passages and arrangements masses and dimensions, static and dynamic strength manoeurrability and reliability are given. To cerry out the correct comparison methods adoped as branch standards thermal calculations, calculation of low-potential part and thermal arrangements, calculations of temperature fields and of low cycle fatigue calculation of the erosion failure accumulation of blades calculation of the blades for the last steps have been used. A conclusion is made that in the nearest future it is necessary to produce the K-1000-60/1500 and K-1000-60/3000 turbines simultaneously. The low-speed lurbines with three LPC are preferable for the nuclear power plants with average annual temperatures of water up to 20 deg C and the high-speed turbines and the K-1000-60/1500 units with two LPC are expedient for nuclear power plants with temperatures higher than 20 deg C. Introduction of the turboplants with reduced number of LPC in the nuclear power engineering provides the increase of reliability, maintenance fitness and the decrease of building costs and transport expenses

  15. Structure, electrical resistivity, and thermal conductivity of beech wood biocarbon produced at carbonization temperatures below 1000°C

    Science.gov (United States)

    Parfen'eva, L. S.; Orlova, T. S.; Kartenko, N. F.; Smirnov, B. I.; Smirnov, I. A.; Misiorek, H.; Jezowski, A.; Muha, J.; Vera, M. C.

    2011-11-01

    This paper reports on measurements of the thermal conductivity κ and the electrical resistivity ρ in the temperature range 5-300 K, and, at 300 K, on X-ray diffraction studies of high-porosity (with a channel pore volume fraction of ˜47 vol %) of the beech wood biocarbon prepared by pyrolysis (carbonization) of tree wood in an argon flow at the carbonization temperature T carb = 800°C. It has been shown that the biocarbon template of the samples studied represents essentially a nanocomposite made up of amorphous carbon and nanocrystallites—"graphite fragments" and graphene layers. The sizes of the nanocrystallites forming these nanocomposites have been determined. The dependences ρ( T) and κ( T) have been measured for the samples cut along and perpendicular to the tree growth direction, thus permitting determination of the magnitude of the anisotropy of these parameters. The dependences ρ( T) and κ( T), which have been obtained for beech biocarbon samples prepared at T carb = 800°C, are compared with the data amassed by us earlier for samples fabricated at T carb = 1000 and 2400°C. The magnitude and temperature dependence of the phonon thermal conductivity of the nanocomposite making up the beech biocarbon template at T carb = 800°C have been found.

  16. To the choice of the regeneration system of the K-1000-68/1500 turbine plant for the NPP with a vertical-type steam generator

    International Nuclear Information System (INIS)

    Kuznetsov, N.M.; Piskarev, A.A.; Grinman, M.I.; Kruglikov, P.A.

    1985-01-01

    Several variants of the heat regeneration system for the NPP with WWER-1000 type reactors using vertical steam generator (SG) generating saturated steam at 7.2 MPa pressure and 200 deg C feed water temperature at the SG inlet are considered. The results of comparison of variants in water and steam circuits of turbine plants are greatly influenced by integral economy account, i.e. efficiency indexes account under variable conditions of power unit operation. From variants of water and steam circuits of the K-1000-68/1500 turbine plant considered preference is given to the variant with four low pressure heaters with increased up to 1.25 MPa pressure in a deacrator without high pressure heater with pumping intermediate steam superheater condensate into feedwater circuit

  17. Self-ignition and oxidation of various hydrocarbons between 600 and 1000 K at high pressure: experimental study with fast compression machine and modeling; Autoinflammation et oxydation de divers hydrocarbures entre 600 et 1000 K a haute pression: etude experimentale en machine a compression rapide et modelisation

    Energy Technology Data Exchange (ETDEWEB)

    Ribaucour, M.

    2002-12-01

    Low- and intermediate-temperature oxidation and self-ignition of hydrocarbons play a major role in spark ignition, diesel and HCCI (homogenous charge compression ignition) engines. A deep understanding of the chemistry linked with both phenomena is necessary to improve the engines efficiency and to reduce the formation of pollutants. This document treats of works about the self-ignition and oxidation at high pressure of various hydrocarbons between 600 and 1000 deg. K. The experimental tool used is a fast compression machine fitted with a fast sampling system for the measurement of self-ignition delays and of the concentrations of intermediate oxidation products. The advantages and limitations of this tool are discussed. The self-ignition of various hydrocarbons is compared using pre-defined data which characterize the phenomenologies like cold flames, negative temperature coefficients and self-ignition limits. The hydrocarbons considered are pure or binary mixtures of alkanes, pent-1-ene and n-butyl-benzene. The development of high pressure oxidation reaction schemes of alkanes between 600 and 1000 deg. K is described. It is directly based on the analysis of intermediate oxidation products. This methodology is also applied to pent-1-ene and n-butyl-benzene. The construction of detailed thermo-kinetic models of oxidation and the modeling of phenomena are made for n-butane, n-heptane, for the 3 pentane isomers, for pent-1-ene and n-butyl-benzene. Finally, the perspectives of future works are evoked. They concern new modeling and new methodologies to be applied in more predictive thermo-kinetic models and the reduction of detailed models in order to include them inside fluid dynamics codes. (J.S.)

  18. Forced convection of ammonia. 2. part.: gaseous ammonia - very high wall temperatures (1000 to 3000 K); Convection forcee de l'ammoniac. 2. partie: ammoniac gazeux - cas de tres hautes temperatures de paroi (1000 a 3000{sup 0} K)

    Energy Technology Data Exchange (ETDEWEB)

    Perroud, P.; Rebiere, J.; Strittmatter, R. [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1969-07-01

    Heat transfer coefficients and pressure drop of gaseous ammonia in forced convection are experimentally determined. The fluid flows (mass flow rate 0.6 to 2.4 g/s) in a long tungsten tube (d{sub i} = 2.8 mm, d{sub e} = 5.1 mm, L = 700 mm) electrically heated. The temperature of the wall reaches 3000 deg. K and the fluid 2500 deg. K; maximum heat flux 530 w/cm{sup 2}. Ammonia is completely dissociated and the power necessary for dissociation reaches 30 per cent of the total power exchanged. Inlet pressure varies between 6 and 16 bars and the maximum pressure drop in the tube reaches 15 bars. Two regimes of dissociation have been shown: catalytic and homogeneous and the variation of dissociation along the length of the tube is studied. The measured heat transfer coefficients may be about 10 times these calculated by the means of classical formulae. A correlation of experimental results using enthalpy as a driving force for heat transmission is presented. Pressure drops may be calculated by the means of a classical friction factor. (authors) [French] On determine experimentalement les coefficients d'echange thermique et les pertes de charge de l'ammoniac gazeux en convection forcee. Le fluide circule avec un debit en masse compris entre 0.6 et 2.4 g/s (G = 10 a 40 g/cm{sup 2}.s) dans un tube long en tungstene (d{sub i} = 2.8 mm, d{sub e} = 5.1 mm, L = 700 mm), chauffe electriquement. La temperature de paroi atteint 3000 deg. K, celle du fluide 2500 deg. K et le flux de chaleur maximal est de 530 W/cm{sup 2}. L'ammoniac se dissocie completement, la puissance correspondant a la dissociation atteint 30 pour cent de la puissance totale echangee. La pression d'entree varie entre 6 et 16 bars et la chute de pression maximale dans le canal est de 15 bars. On distingue deux regimes de dissociation, catalytique et homogene, et on etudie la variation du taux de dissociation en fonction de la longueur du tube. Les coefficients d'echange thermique mesures

  19. A procedure for temperature-stress fields calculation of WWER-1000 primary circuit in PTS event

    Energy Technology Data Exchange (ETDEWEB)

    Petkov, G [Technical Univ., Dept. Thermal and Nuclear Power Engineering, Sofia (Bulgaria); Groudev, P; Argirov, J [Bulgarian Academy of Science, Inst. for Nuclear Research and Nuclear Energy, Sofia (Bulgaria)

    1997-09-01

    The paper presents the procedure of an investigation of WWER-1000 primary circuit temperature-stress field by the use of thermohydraulic computation data for a pressurized thermal shock event ``Core overcooling``. The procedure is based on a model of the plane stress state with ideal contact between wall and medium for the calculation. The computation data are calculated on the base of WWER-1000 thermohydraulic model by the RELAP5/MOD3 codes. This model was developed jointly by the Bulgarian and BNL/USA staff to provide an analytical tool for performing safety analysis. As a result of calculations by codes the computation data for temperature field law (linear laws of a few distinguished parts) and pressure of coolant at points on inner surface of WWER-1000 primary circuit equipment are received. Such calculations can be used as a base for determination of all-important load-carrying sections of the primary circuit pipes and vessels, which need further consideration. (author). 7 refs, 2 figs, 2 tabs.

  20. A 20mK temperature sensor

    International Nuclear Information System (INIS)

    Wang, N.; Sadoulet, B.; Shutt, T.

    1987-11-01

    We are developing a 20mK temperature sensor made of neutron transmutation doped (NTD) germanium for use as a phonon detector in a dark matter search. We find that NTD germanium thermistors around 20mK have resistances which are a strong function of temperature, and have sufficient sensitivity to eventually reach a base line rms energy fluctuation of 6eV at 25mK. Further work is needed to understand the extreme sensitivity of the thermistors to bias power. 13 refs., 18 figs

  1. Study of the flux effect nature for VVER-1000 RPV welds with high nickel content

    Energy Technology Data Exchange (ETDEWEB)

    Kuleshova, E.A., E-mail: evgenia-orm@yandex.ru [National Research Center “Kurchatov Institute”, Kurchatov Sq.1, 123182, Moscow (Russian Federation); National Research Nuclear University, “MEPhI” (Moscow Engineering Physics Institute), Kashirskoe Highway 31, 115409, Moscow (Russian Federation); Gurovich, B.A.; Lavrukhina, Z.V.; Maltsev, D.A.; Fedotova, S.V.; Frolov, A.S.; Zhuchkov, G.M. [National Research Center “Kurchatov Institute”, Kurchatov Sq.1, 123182, Moscow (Russian Federation)

    2017-01-15

    This work extends the research of the basic regularities of segregation processes in the grain boundaries (GB) of VVER-1000 reactor pressure vessel (RPV) steels. The paper considers the influence of irradiation with different fast neutron fluxes on the structure, yield strength and ductile-to-brittle transition temperature (T{sub K}) changes as well as on changes of the share of brittle intergranular fracture and development of segregation processes in the VVER-1000 RPV weld metal (WM). The obtained experimental results allow to separate the contribution of the hardening and non-hardening mechanisms to mechanical properties degradation of material irradiated at the operating temperature. It is shown that the difference in T{sub K} shift in WM irradiated to the same fluence with different fast neutron fluxes is mainly due to the difference in the GB accumulation kinetics of impurities and only to a small extent due to the material hardening. Phosphorus bulk diffusion coefficients were evaluated for the temperature exposure, accelerated irradiation and irradiation within surveillance specimens (SS) using a kinetic model of phosphorus GB accumulation in low-alloyed low-carbon steels under the influence of operational factors. The correlation between the GB segregation level of phosphorus and nickel, and the T{sub K} shift - in WM SS was obtained experimentally and indicates the non-hardening mechanism contribution to the total radiation embrittlement of VVER-1000 RPV steels throughout its extended lifetime. - Highlights: • Structural elements in high Ni welds are studied at different irradiation fluxes. • AES study demonstrated different P GB kinetics at different irradiation fluxes. • Hardening and non-hardening mechanism contributions to the flux effect are assessed. • Correlation between ΔT{sub K} and P and Ni GB content is shown for VVER-1000 RPV welds.

  2. In-situ high temperature irradiation setup for temperature dependent structural studies of materials under swift heavy ion irradiation

    International Nuclear Information System (INIS)

    Kulriya, P.K.; Kumari, Renu; Kumar, Rajesh; Grover, V.; Shukla, R.; Tyagi, A.K.; Avasthi, D.K.

    2015-01-01

    An in-situ high temperature (1000 K) setup is designed and installed in the materials science beam line of superconducting linear accelerator at the Inter-University Accelerator Centre (IUAC) for temperature dependent ion irradiation studies on the materials exposed with swift heavy ion (SHI) irradiation. The Gd 2 Ti 2 O 7 pyrochlore is irradiated using 120 MeV Au ion at 1000 K using the high temperature irradiation facility and characterized by ex-situ X-ray diffraction (XRD). Another set of Gd 2 Ti 2 O 7 samples are irradiated with the same ion beam parameter at 300 K and simultaneously characterized using in-situ XRD available in same beam line. The XRD studies along with the Raman spectroscopic investigations reveal that the structural modification induced by the ion irradiation is strongly dependent on the temperature of the sample. The Gd 2 Ti 2 O 7 is readily amorphized at an ion fluence 6 × 10 12 ions/cm 2 on irradiation at 300 K, whereas it is transformed to a radiation-resistant anion-deficient fluorite structure on high temperature irradiation, that amorphized at ion fluence higher than 1 × 10 13 ions/cm 2 . The temperature dependent ion irradiation studies showed that the ion fluence required to cause amorphization at 1000 K irradiation is significantly higher than that required at room temperature irradiation. In addition to testing the efficiency of the in-situ high temperature irradiation facility, the present study establishes that the radiation stability of the pyrochlore is enhanced at higher temperatures

  3. The behavior of the Tevatron at energies greater than 1000 GeV

    International Nuclear Information System (INIS)

    Pogorelko, O.

    1991-04-01

    If, as appears likely, the top quark lies at the upper range of the mass reach of the Tevatron, then increasing the energy of the collider operation could prove to be a crucial factor in the future program together with projected luminosity enhancements. While a significant amount of data exists on individual magnets up to an energy of 1000 GeV, there are no detailed measurements above this value. We focus on the operating range beyond 1000 GeV in an attempt to see whether there is any realistic opportunity to extend the energy range of the Tevatron into this regime. The proposed modifications to the Tevatron Cryogenic System will provide sufficient cooling to lower the operating temperature of the 1000 superconducting magnets from the present 4.6--4.8K (1-φ inlet temperature) down to a range of 3.6--3.8K. At this temperature the short sample quench current for the dipole magnets should increase from the present value of ∼4000A (900 GeV) up to a level approaching 4800A (1100 GeV.) Increasing the peak current in the dipoles produces some important questions related to possible mechanical effects including catastrophic failure, the change of magnetic field quality, and quench protection problems resulting from the increased stored energy. In this note we shall examine these effects and comment on the existing data on low temperature operation. We have only considered the dipole magnets since the quadrupoles should not limit performance. We have not looked at the interaction region magnets which involve different considerations

  4. On high temperature internal friction in metallic glasses

    International Nuclear Information System (INIS)

    Zolotukhin, I.V.; Kalinin, Yu.E.; Roshchupkin, A.M.

    1992-01-01

    High temperature background of internal friction in amorphous lanthanum-aluminium alloys was investigated. More rapid growth of internal friction was observed at temperature ∼ 453 K reaching maximal value at 495 K. Crystallization process was accompanied by decrease of internal friction. Increase of mechanical vibration frequency to 1000 Hz leads to rise of internal friction background in the range of room temperatures and to decrease at temperatures above 370 K. Bend was observed on temperature dependence of internal friction at 440 K

  5. Effects of 1000 C oxide surfaces on room temperature aqueous corrosion and environmental embrittlement of iron aluminides

    Energy Technology Data Exchange (ETDEWEB)

    Buchanan, R.A.; Perrin, R.L. [Univ. of Tennessee, Knoxville, TN (United States). Dept. of Materials Science and Engineering

    1997-12-01

    Results of electrochemical aqueous-corrosion studies at room temperature indicate that retained in-service-type high-temperature surface oxides (1000 C in air for 24 hours) on FA-129, FAL and FAL-Mo iron aluminides cause major reductions in pitting corrosion resistance in a mild acid-chloride solution designed to simulate aggressive atmospheric corrosion. Removal of the oxides by mechanical grinding restores the corrosion resistance. In a more aggressive sodium tetrathionate solution, designed to simulate an aqueous environment contaminated by sulfur-bearing combustion products, only active corrosion occurs for both the 1000 C oxide and mechanically cleaned surfaces at FAL. Results of slow-strain-rate stress-corrosion-cracking tests on FA-129, FAL and FAL-Mo at free-corrosion and hydrogen-charging potentials in the mild acid chloride solution indicate somewhat higher ductilities (on the order of 50%) for the 1000 C oxides retard the penetration of hydrogen into the metal substrates and, consequently, are beneficial in terms of improving resistance to environmental embrittlement. In the aggressive sodium tetrathionate solution, no differences are observed in the ductilities produced by the 1000 C oxide and mechanically cleaned surfaces for FAL.

  6. Charging kinetics in virgin and 1 MeV-electron irradiated yttria-stabilized zirconia in the 300-1000 K range

    International Nuclear Information System (INIS)

    Thome, T.; Braga, D.; Blaise, G.; Cousty, J.; Pham Van, L.; Costantini, J.M.

    2006-01-01

    A study performed with a dedicated scanning electron microscope (SEM) on the surface electrical properties of (1 0 0)-oriented yttria-stabilized zirconia (YSZ) single crystals irradiated with 1 MeV electrons is presented. When compared with virgin YSZ, the 1 MeV-irradiated YSZ shows a decrease of the intrinsic total electron emission coefficient σ 0 and an increase of the time constant τ associated with the charging kinetics of the material at room temperature. These measurements performed with the SEM beam at 10 keV indicate that the defects induced by the 1 MeV-electron irradiation generate a positive electric field of the order of 0.5 x 10 6 V/m at a depth of about 1 μm that prevents electrons to escape. When the SEM beam with a 1.1 keV energy is used, a smaller field (∼0.5 x 10 3 V/m) is detected closer to the surface (∼20 nm). The fading of these fields during the thermal annealing in the 400-1000 K temperature range provides information on the nature of defects induced by the 1 MeV-electron irradiation

  7. High temperature and high pressure gas cell for quantitative spectroscopic measurements

    International Nuclear Information System (INIS)

    Christiansen, Caspar; Stolberg-Rohr, Thomine; Fateev, Alexander; Clausen, Sønnik

    2016-01-01

    A high temperature and high pressure gas cell (HTPGC) has been manufactured for quantitative spectroscopic measurements in the pressure range 1–200 bar and temperature range 300–1300 K. In the present work the cell was employed at up to 100 bar and 1000 K, and measured absorption coefficients of a CO_2–N_2 mixture at 100 bar and 1000 K are revealed for the first time, exceeding the high temperature and pressure combinations previously reported. This paper discusses the design considerations involved in the construction of the cell and presents validation measurements compared against simulated spectra, as well as published experimental data. - Highlights: • A ceramic gas cell designed for gas measurements up to 1300 K and 200 bar. • The first recorded absorption spectrum of CO_2 at 1000 K and 101 bar is presented. • Voigt profiles might suffice in the modeling of radiation from CO_2 in combustion.

  8. The monitoring and fatigue behavior of CFCCs at ambient temperature and 1000 degrees C

    International Nuclear Information System (INIS)

    Miriyala, N.; Liaw, P.K.; McHargue, C.J.

    1997-01-01

    Metallographically polished flexure bars of Nicalon/SiC and Nicalon/alumina composites were subjected to monotonic and cycle-fatigue loadings, with loading either parallel or normal to the fabric plies. The fabric orientation did not significantly affect the mechanical behavior of the Nicalon/SiC composite at ambient temperature. However, the mechanical behavior of the Nicalon/alumina composite was significantly affected by the fabric orientation at ambient temperature in air and at 1000 degrees C in argon atmosphere. In addition, there was a significant degradation in the fatigue performance of the alumina matrix composite at the elevated temperature, owing to creep in the material and degradation in the fiber strength

  9. The monitoring and fatigue behavior of CFCCs at ambient temperature and 1000{degrees}C

    Energy Technology Data Exchange (ETDEWEB)

    Miriyala, N.; Liaw, P.K.; McHargue, C.J. [Univ. of Tennessee, Knoxville, TN (United States)] [and others

    1997-04-01

    Metallographically polished flexure bars of Nicalon/SiC and Nicalon/alumina composites were subjected to monotonic and cycle-fatigue loadings, with loading either parallel or normal to the fabric plies. The fabric orientation did not significantly affect the mechanical behavior of the Nicalon/SiC composite at ambient temperature. However, the mechanical behavior of the Nicalon/alumina composite was significantly affected by the fabric orientation at ambient temperature in air and at 1000{degrees}C in argon atmosphere. In addition, there was a significant degradation in the fatigue performance of the alumina matrix composite at the elevated temperature, owing to creep in the material and degradation in the fiber strength.

  10. High temperature and high pressure gas cell for quantitative spectroscopic measurements

    DEFF Research Database (Denmark)

    Christiansen, Caspar; Stolberg-Rohr, Thomine; Fateev, Alexander

    2016-01-01

    A high temperature and high pressure gas cell (HTPGC) has been manufactured for quantitative spectroscopic measurements in the pressure range 1-200 bar and temperature range 300-1300 K. In the present work the cell was employed at up to 100 bar and 1000 K, and measured absorption coefficients...... of a CO2-N2 mixture at 100 bar and 1000 K are revealed for the first time, exceeding the high temperature and pressure combinations previously reported. This paper discusses the design considerations involved in the construction of the cell and presents validation measurements compared against simulated...

  11. Temperature dependence of thermal expansion of cadmium sulfide in the temperature range 20 - 820 K

    International Nuclear Information System (INIS)

    Oskotskij, V.S.; Kobyakov, I.B.; Solodukhin, A.V.

    1980-01-01

    The linear thermal expansion of cadmium sulfide is measured perpendicularly (α 1 ) and parallelly (α 2 ) to the hexagonal axis in the temperature range from 20 to 820 K. Anisotropy is low at up to 80 K; rises at higher temperatures; at 3OO K α 1 /α 3 ratio is 1.8; at 820 K, 2.4. Heat expansion is negative at temperatures lower than 104.5 K(α 1 ) and 126.0 K(α 2 ). It achieves the minimum at 43.6 K (α 1 ) and 52.5K (α 3 ). The theory of heat expansion is plotted in the Debue, approximation and cadmium sulfide is considered as an isotope crystal with average elastic constants. Two parameters of the theory are determined by the position and value of the minimum of volumetric thermal expansion of the model isotope crystal. The theoretic curve agrees well with the experimental one at temperatures up to 160 K, i.e in the range of applicability of the Debue approximation and the isotropic model

  12. Experimental investigation on tritium release from lithium titanate pebble under high temperature of 1073 K

    Energy Technology Data Exchange (ETDEWEB)

    Ochiai, Kentaro, E-mail: howartre@onid.oregonstate.edu [Japan Atomic Energy Agency, Tokai-mura, Naka-gun, Ibaraki (Japan); Edao, Yuki; Kawamura, Yoshinori [Japan Atomic Energy Agency, Tokai-mura, Naka-gun, Ibaraki (Japan); Hoshino, Tsuyoshi [Japan Atomic Energy Agency, Rokkasho-mura, Kamikita-gun, Aomori (Japan); Ohta, Masayuki; Sato, Satoshi; Konno, Chikara [Japan Atomic Energy Agency, Tokai-mura, Naka-gun, Ibaraki (Japan)

    2015-10-15

    Highlights: • We have performed the tritium recovery experiment with the DT neutron source at 1073 K. • The tritium recovery corresponded with the calculated tritium production. • The chemical form of recovered tritium is affected by the temperature and kind of sweep gas. • The recovered HT increases at higher temperature and dry hydrogen circumstance. - Abstract: The temperature of Li{sub 2}TiO{sub 3} pebble breeder in a fusion DEMO blanket is assumed to be more than 1000 K. For the investigation of tritium release from a Li{sub 2}TiO{sub 3} pebble breeder blanket at such a high temperature, we have carried out a tritium release experiment with the DT neutron source at the JAEA-FNS. The Li{sub 2}TiO{sub 3} pebble (1.0–1.2 mm in diameter) of 70 g was put into a stainless steel container and installed into an assembly stratified with beryllium and Li{sub 2}TiO{sub 3} layers. During the DT neutron irradiation, the temperature was kept at 1073 K with wire heaters in the blanket container. Helium gas including 1% hydrogen gas (H{sub 2}/He) mainly flowed inside the container as the purge gas. Two chemical forms, HT and HTO, of extracted tritium were separately collected during the DT neutron irradiation by using water bubblers and CuO bed. The tritium activity in the water bubbler was measured by a liquid scintillation counter. To investigate the effect of moisture in the purge gas, we also performed the same experiments with H{sub 2}O/He gas (H{sub 2}O content: 1%) or pure helium gas. From our experiment at 1073 K, in the case of the purge gas includes H{sub 2}, it is indicated that the increasing tendency of HT release is similar to that of the dry H{sub 2}/He.

  13. Temperature dependence of muonium spin exchange with O2 in the range 88 K to 478 K

    International Nuclear Information System (INIS)

    Senba, M.; Garner, D.M.; Arseneau, D.J.; Fleming, D.G.

    1984-01-01

    The authors have extended an earlier study of the spin exchange reactions of Mu with O 2 in the range 295 K to 478 K, to a low temperature region down to 88 K. From 135 K to 296 K, the spin depolarization rate constant was found to vary according to the relative velocity of the colliding species, which indicates that the spin exchange cross section of Mu-O 2 is temperature independent in this range. However, it was found that below 105 K and above 400 K, the spin depolarization rate constant tends to have stronger temperature dependences. (Auth.)

  14. On Extracting Mechanical Properties from Nanoindentation at Temperatures up to 1000$^{\\circ}$C

    OpenAIRE

    Gibson, James S. K. -L.; Schröders, Sebastian; Zehnder, Christoffer; Korte-Kerzel, Sandra

    2017-01-01

    Alloyed MCrAlY bond coats, where M is usually cobalt and/or nickel, are essential parts of modern turbine blades, imparting environmental resistance while mediating thermal expansivity differences. Nanoindentation allows the determination of their properties without the complexities of traditional mechanical tests, but was not previously possible near turbine operating temperatures. Here, we determine the hardness and modulus of CMSX-4 and an Amdry-386 bond coat by nanoindentation up to 1000$...

  15. Future market relevance of CHP installations with electrical ratings from 1 to 1000 kW; Zukuenftige Marktbedeutung von WKK-Anlagen mit 1 - 1000 kW elektrischer Leistung

    Energy Technology Data Exchange (ETDEWEB)

    Eicher, H.; Rigassi, R.

    2003-12-15

    This report for the Swiss Federal Office of Energy (SFOE) discusses the future market relevance of combined heat and power (CHP) installations with electrical ratings from 1 to 1000 kW. Developments over the past ten years are reviewed. Important reductions in the price of motor-driven CHP units and the price of the electrical power produced are noted and commented on. The technical market potential of CHP units and the degree to which this potential has been implemented are commented on. Work done, including CHP implementation in the industrial, commercial and residential areas, is commented on. Future developments both in the technical area as well as in commercial areas are commented on. Micro-gas-turbine based CHP systems are also discussed, as are fuel-cell based systems in both the higher and lower capacity power generation area. The prospects for CHP systems in general in the electricity generation area are discussed

  16. A Probability Analysis of the Generating Cost for APR1000+

    Energy Technology Data Exchange (ETDEWEB)

    Ha, Gag-Hyeon; Kim, Dae-Hun [KHNP CRI, Daejeon (Korea, Republic of)

    2016-10-15

    The nuclear power plant market is expected to grow rapidly in order to address issues of global warming, cutting CO{sub 2} emissions and securing stable electricity supplies. Under these circumstances, the main primary goal of the APR1000+ development is to ensure export competitiveness in the developing countries in the Middle East and Southeast Asia. To that end, APR1000+(1,000MWe, 3.5 generation) will be developed based on APR+ (1,500MWe, 3.5 generation). And comparing to OPR1000(Korean Standard Nuclear power Plant, 2.5 generation), APR1000+ have many design features such as the 60 year design life time, comprehensive site requirement of 0.3g seismic design, stability improvement, operability improvement and provisions for severe accidents. In this simulation, the results of generating cost for APR1000+ preliminary conceptual design using a probability method was shown to be 48.37 ~ 74.22 won/kWh(median value 56.51 won/kWh). Those of OPR1000 was 42.08 ~ 61.77 won/kWh(median value 48.63 won/kWh). APR1000+ has -16.2% cost advantage over OPR1000 nuclear power plant. The main reason of this results is due to adding several safety designs.

  17. The refrigeration of high temperature superconductors between 25K and 65K

    International Nuclear Information System (INIS)

    Richardson, R.N.; Scurlock, R.G.; Tavner, A.C.R.

    1996-01-01

    The present state of the art indicates that acceptable j - H characteristics for power applications of the new high Tc superconductors will only be achieved using materials at temperatures below liquid nitrogen temperature. A boiling point of 27.1K and high specific cooling capacity make neon an eminently suitable choice of refrigerant at these temperatures. A cryostat has been constructed which employs a two stage Gifford-McMahon cooler to liquefy neon gas. The cryostat contains up to 5 litres of liquid neon which can be used for open-quote in-situ close-quote experiments or transfer to another cryostat. Another set of cryostats are being used with liquid nitrogen/oxygen mixtures at reduced pressure for temperatures down to 50K. All these cryostats provide a core facility for characterising and operating high T c superconductors at Southampton

  18. 24 CFR 35.1000 - Purpose and applicability.

    Science.gov (United States)

    2010-04-01

    ... 24 Housing and Urban Development 1 2010-04-01 2010-04-01 false Purpose and applicability. 35.1000 Section 35.1000 Housing and Urban Development Office of the Secretary, Department of Housing and Urban..., Support Services, or Operation § 35.1000 Purpose and applicability. (a) The purpose of this subpart K is...

  19. The Cu-Te-Sb phase system at temperatures between 300 and 1000 degree C

    DEFF Research Database (Denmark)

    Karup-Møller, Sven

    1997-01-01

    Phase relations were determined in the Cu-Te-Sb phase system at 300, 350, 400, 500, 600, 700, 800, 900 and 1000 degree C. At temperatures between 400 and 900 degree C a cubic primitive ternary phase A exists. It has the empirical formula Cu(10.32-0.97x)Te(x)Sb(4-x) (Z=2, a=7.682 Å). A small liquid...

  20. Vähemalt 1000-euroste arvete deklareerimine / Tõnis Elling

    Index Scriptorium Estoniae

    Elling, Tõnis, 1972-

    2014-01-01

    1. novembril 2014 jõustuvast käibemaksuseaduse muudatusest, mille kohaselt peavad kõik käibemaksukohustuslased hakkama käibedeklaratsiooni (KMD) lisal INF deklareerima vähemalt 1000 euro suuruseid arveid

  1. Effect of temperature during ion sputtering on the surface segregation rate of antimony in an iron-antimony alloy at higher temperatures

    International Nuclear Information System (INIS)

    Oku, M.; Hirokawa, K.; Kimura, H.; Suzuki, S.

    1986-01-01

    The surface segregation of antimony in an iron-0.23 at% antimony alloy was studied by XPS. The segregation rate in the temperature range between 800 and 900 K depends on the temperature during sputtering with argon ion of kinetic energy of 1 keV. The sputtering at room temperature or 473 K gives higher values of the segregation rate than those at 673 K. Both cases give the activation energy of 170 kJmol -1 for the surface segregation rate. The segregation of antimony is not observed after the sample is heated at 1000 K. (author)

  2. High-Temperature Heat Capacity of Germanates Pr2Ge2O7 and Nd2Ge2O7 within 350-1000 K

    Science.gov (United States)

    Denisova, L. T.; Irtyugo, L. A.; Beletskii, V. V.; Belousova, N. V.; Denisov, V. M.

    2018-03-01

    Pr2Ge2O7 and Nd2Ge2O7 were obtained via solid-phase synthesis from Pr2O3 ( Nd2O3) and GeO2 with multistage firing in air within 1273-1473 K. A temperature effect on molar heat capacity of the oxide compounds was measured with a differential scanning calorimetry. Their thermodynamic properties were calculated from the C P = f( T) dependences.

  3. Fish-T1K (Transcriptomes of 1,000 Fishes) Project: large-scale transcriptome data for fish evolution studies.

    Science.gov (United States)

    Sun, Ying; Huang, Yu; Li, Xiaofeng; Baldwin, Carole C; Zhou, Zhuocheng; Yan, Zhixiang; Crandall, Keith A; Zhang, Yong; Zhao, Xiaomeng; Wang, Min; Wong, Alex; Fang, Chao; Zhang, Xinhui; Huang, Hai; Lopez, Jose V; Kilfoyle, Kirk; Zhang, Yong; Ortí, Guillermo; Venkatesh, Byrappa; Shi, Qiong

    2016-01-01

    Ray-finned fishes (Actinopterygii) represent more than 50 % of extant vertebrates and are of great evolutionary, ecologic and economic significance, but they are relatively underrepresented in 'omics studies. Increased availability of transcriptome data for these species will allow researchers to better understand changes in gene expression, and to carry out functional analyses. An international project known as the "Transcriptomes of 1,000 Fishes" (Fish-T1K) project has been established to generate RNA-seq transcriptome sequences for 1,000 diverse species of ray-finned fishes. The first phase of this project has produced transcriptomes from more than 180 ray-finned fishes, representing 142 species and covering 51 orders and 109 families. Here we provide an overview of the goals of this project and the work done so far.

  4. Preparation of Nb thin films with bulk transition temperatures

    Energy Technology Data Exchange (ETDEWEB)

    Peirce, L H [Florida State Univ., Tallahassee (USA). Dept. of Physics

    1984-08-01

    Thin films (1000-2000 A) of Nb were prepared with bulk transition temperatures (9.25 K) by evaporation from an electron gun. Necessary substrate temperatures, evaporation rates and H/sub 2/O pressures were determined.

  5. Effect of Activation Temperature on CO{sub 2} Capture Behaviors of Resorcinol-based Carbon Aerogels

    Energy Technology Data Exchange (ETDEWEB)

    Moon, Cheolwhan; Im, Seungsoon; Park, Soojin [Hanyang Univ., Seoul (Korea, Republic of); Kim, Youngjoo [Inha Univ., Incheon (Korea, Republic of)

    2014-01-15

    In this study, carbon aerogel (CA) was synthesized using a soft-template method, and the optimum conditions for the adsorption of carbon dioxide (CO{sub 2}) by the carbon aerogel were evaluated by controlling the activation temperature. KOH was used as the activation agent at a KOH/CA activation ratio of 4:1. Three types of activated CAs were synthesized at activation temperatures of 800 .deg. C (CA-K-800), 900 .deg. C (CA-K-900), and 1000 .deg. C (CA-K-1000), and their surface and pore characteristics along with the CO{sub 2} adsorption characteristics were examined. The results showed that with the increase in activation temperature from 800 to 900 .deg. C, the total pore volume and specific surface area sharply increased from 1.2165 to 1.2500 cm{sup 3}/g and 1281 to 1526 m{sup 2}/g, respectively. However, the values for both these parameters decreased at temperatures above 1000 .deg. C. The best CO{sub 2} adsorption capacity of 10.9 wt % was obtained for the CA-K-900 sample at 298 K and 1 bar. This result highlights the importance of the structural and textural characteristics of the carbon aerogel, prepared at different activation temperatures on CO{sub 2} adsorption behaviors.

  6. Interaction processes between vacancies and dislocations in molybdenum in the temperature range around 0.3 of the melting temperature

    International Nuclear Information System (INIS)

    Zelada-Lambri, G.I.; Lambri, O.A.; Bozzano, P.B.; Garcia, J.A.; Celauro, C.A.

    2008-01-01

    Mechanical spectroscopy, electrical resistivity and transmission electron microscopy studies have been performed on pre-strained neutron irradiated single crystalline molybdenum in order to check the interaction processes between vacancies and dislocations in the temperature range between room temperature and 1273 K. The anelastic relaxation in molybdenum which appears between 800 K and 1273 K has been separated in two different physical mechanisms depending on the temperature of appearance of the relaxation peak. The physical mechanism which controls the damping peak appearing at around 800 K was related with the dragging of jogs by the dislocation under movement assisted by vacancy diffusion. The damping peak which appears at higher temperatures of about 1000 K was more consistent with the formation and diffusion of vacancies assisted by the dislocation movement

  7. Interaction processes between vacancies and dislocations in molybdenum in the temperature range around 0.3 of the melting temperature

    Energy Technology Data Exchange (ETDEWEB)

    Zelada-Lambri, G.I. [Facultad de Ciencias Exactas, Ingenieria y Agrimensura, Universidad Nacional de Rosario, Laboratorio de Materiales, Escuela de Ingenieria Electrica, Avenida Pellegrini 250, 2000 Rosario (Argentina); Lambri, O.A. [Facultad de Ciencias Exactas, Ingenieria y Agrimensura, Universidad Nacional de Rosario, Laboratorio de Materiales, Escuela de Ingenieria Electrica, Avenida Pellegrini 250, 2000 Rosario (Argentina); Instituto de Fisica Rosario, Member of the CONICET' s Research Staff (Argentina)], E-mail: olambri@fceia.unr.edu.ar; Bozzano, P.B. [Laboratorio de Microscopia Electronica, Unidad de Actividad Materiales, Centro Atomico Constituyentes, Comision Nacional de Energia Atomica, Avenida General Paz 1499, 1650 San Martin (Argentina); Garcia, J.A. [Departamento de Fisica Aplicada II, Facultad de Ciencias y Tecnologia, Universidad del Pais Vasco, Apartado 644, 48080 Bilbao, Pais Vasco (Spain); Celauro, C.A. [Reactor Nuclear RA-4, Facultad de Ciencias Exactas, Ingenieria y Agrimensura, Universidad Nacional de Rosario, Riobamba y Berruti, 2000 Rosario (Argentina)

    2008-10-15

    Mechanical spectroscopy, electrical resistivity and transmission electron microscopy studies have been performed on pre-strained neutron irradiated single crystalline molybdenum in order to check the interaction processes between vacancies and dislocations in the temperature range between room temperature and 1273 K. The anelastic relaxation in molybdenum which appears between 800 K and 1273 K has been separated in two different physical mechanisms depending on the temperature of appearance of the relaxation peak. The physical mechanism which controls the damping peak appearing at around 800 K was related with the dragging of jogs by the dislocation under movement assisted by vacancy diffusion. The damping peak which appears at higher temperatures of about 1000 K was more consistent with the formation and diffusion of vacancies assisted by the dislocation movement.

  8. Structural properties of gold clusters at different temperatures

    CSIR Research Space (South Africa)

    Mahladisa, MA

    2005-09-01

    Full Text Available A series of gold clusters consisting of aggregates of from 13 to 147 atoms was studied using the Sutton-Chen type many-body potential in molecular dynamics simulations. The properties of these clusters at temperatures from 10 K to 1000 K were...

  9. Ferrite-free high power electrodeless fluorescent lamp operated at a frequency of 160-1000 kHz

    International Nuclear Information System (INIS)

    Popov, Oleg A; Chandler, Robert

    2002-01-01

    An electrodeless ferrite-free fluorescent lamp of a closed-loop type ('tokamak') was studied at a driving frequency, f = 160-1000 kHz, and power of 100-250 W. The inductive discharge was ignited in the mercury-argon mixture with the help of an induction coil of several (7-15) turns made from multiple-strand (Litz) wire. The discharge parameters - current, resistance, and electric field - were calculated using the transformer model of an RF inductive discharge. They were found to be close to those measured in a plasma of a 'tokamak'-type lamp operated at the same frequency and RF power but with the use of the ferrite cores. The ferrite-free lamp had high luminous efficacy as high as 85 LPW at a frequency, f>200 kHz, and power of 100-200 W. Such a high efficacy is attributed to low coil power losses ( 90%

  10. Semiconductor resistance thermometer for the temperature range 300-0.3 K

    International Nuclear Information System (INIS)

    Zinov'eva, K.N.; Zarubin, L.I.; Nemish, I.Yu.; Vorobkalo, F.M.; Boldarev, S.T.; AN Ukrainskoj SSR, Kiev. Inst. Poluprovodnikov)

    1979-01-01

    Thermometric characteristics of semiconductor resistor thermometers for the temperature range from 300 to 0.3 K and from 77 to 0.3 K are given. Temperature dependence of thermometer resistances in the 300-1.3 K range was measured in cryostats with pumping-out of N 2 , H 2 and 4 He. For measurements below 1.3 K use was made of a 3 H- 4 He dissolving cryostat. The accuracy of measuring temperatures in the 1.3-0.3 K range is not below +-0.003 K, the error in determining thermometer resistances does not exceed 1%. The analysis of obtained thermometric characteristics of several series of semiconductor resistance thermometers showed that observed insignificant spread of resistances of thermometers in one series and identity of characteristics allows them to be used without preliminary calibration for relatively coarse measurements in the range from 3O0 to 0.3 K. Besides, it has been found that in the 4.2-0.3 K range the thermometric characteristics represent a straight line in the lgR-Tsup(-n) coordinates, where R is the thermometer resistance, T is the temperature and n=0.5. Thus, the thermometers of the same series can be calibrated only in 2 or 3 reference point measurements

  11. Simvastatin: structure solution of two new low-temperature phases from synchrotron powder diffraction and ss-NMR

    Czech Academy of Sciences Publication Activity Database

    Hušák, M.; Kratochvíl, B.; Jegorov, A.; Brus, Jiří; Maixner, J.; Rohlíček, J.

    2010-01-01

    Roč. 21, č. 3 (2010), s. 511-518 ISSN 1040-0400 R&D Projects: GA AV ČR IAA400500602; GA MŠk 2B08021 Institutional research plan: CEZ:AV0Z40500505 Keywords : crystal structure * simvastatin * powder diffraction Subject RIV: CD - Macromolecular Chemistry Impact factor: 1.727, year: 2010

  12. Development of an experimental variable temperature set-up for a temperature range from 2.2 K to 325 K for cost-effective temperature sensor calibration

    Science.gov (United States)

    Pal, Sandip; Kar, Ranjan; Mandal, Anupam; Das, Ananda; Saha, Subrata

    2017-05-01

    A prototype of a variable temperature insert has been developed in-house as a cryogenic thermometer calibration facility. It was commissioned in fulfilment of the very stringent requirements of the temperature control of the cryogenic system. The calibration facility is designed for calibrating industrial cryogenic thermometers that include a temperature sensor and the wires heat-intercept in the 2.2 K-325 K temperature range. The isothermal section of the calibration block onto which the thermometers are mounted is weakly linked with the temperature control zone mounted with cooling capillary coil and cryogenic heater. The connecting wires of the thermometer are thermally anchored with the support of the temperature insert. The calibration procedure begins once the temperature of the support is stabilized. Homogeneity of the calibration block’s temperature is established both by simulation and by cross-comparison of two calibrated sensors. The absolute uncertainty present in temperature measurement is calculated and found comparable with the measured uncertainty at different temperature points. Measured data is presented in comparison to the standard thermometers at fixed points and it is possible to infer that the absolute accuracy achieved is better than  ±0.5% of the reading in comparison to the fixed point temperature. The design and development of simpler, low cost equipment, and approach to analysis of the calibration results are discussed further in this paper, so that it can be easily devised by other researchers.

  13. Fused silica thermal conductivity dispersion at high temperature

    International Nuclear Information System (INIS)

    Bouchut, P.; Decruppe, D.; Delrive, L.

    2004-01-01

    A continuous CO 2 laser is focused to locally anneal small fused silica spots. A noncontact radiometry diagnostic enables us to follow surface temperature variation that occurs from site to site. A 'steady state' dispersion of surface temperature is observed across our sample. We show that nonhomogeneous silica thermal conductivity, above 1000 K is responsible for this temperature dispersion

  14. Effect of high-temperature filtration on impurity composition in the primary circuit coolant of power units with WWER-1000 reactors

    International Nuclear Information System (INIS)

    Efimov, A.A.; Moskvin, L.N.; Gusev, B.A.; Leont'ev, G.G.; Nekrest'yanov, S.N.

    1992-01-01

    The effects of high-temperature filtration on changes in dispersive, chemical, radioisotope and phase compositions of impurities in primary circuit coolant of NPP with the WWER-1000 reactor are studied. Special filters are used for the studies. The data obtained confirm the applicability of high-temperature filtration for purification of WWER reactor water and steam separators at NPPs with RBMK reactors

  15. JSD1000: multi-group cross section sets for shielding materials

    International Nuclear Information System (INIS)

    Yamano, Naoki

    1984-03-01

    A multi-group cross section library for shielding safety analysis has been produced by using ENDF/B-IV. The library consists of ultra-fine group cross sections, fine-group cross sections, secondary gamma-ray production cross sections and effective macroscopic cross sections for typical shielding materials. Temperature dependent data at 300, 560 and 900 K have been also provided. Angular distributions of the group to group transfer cross section are defined by a new method of ''Direct Angular Representation'' (DAR) instead of the method of finite Legendre expansion. The library designated JSD1000 are stored in a direct access data base named DATA-POOL and data manipulations are available by using the DATA-POOL access package. The 3824 neutron group data of the ultra-fine group cross sections and the 100 neutron, 20 photon group cross sections are applicable to shielding safety analyses of nuclear facilities. This report provides detailed specifications and the access method for the JSD1000 library. (author)

  16. Verification results of methodology for determining the weighted mean coolant temperature in the primary circuit hot legs of WWER-1000 reactor plants

    International Nuclear Information System (INIS)

    Saunin, Yuri V.; Dobrotvorski, Alexander N.; Semenikhin, Alexander V.; Korolev, Alexander S.

    2017-01-01

    The JSC ''Atomtechenergo'' experts have developed a new methodology for determining the weighted mean coolant temperature in the primary circuit hot legs of WWER-1000 reactor plants. The necessity for developing the new methodology was determined by the need to decrease the calculation error of the weighted mean coolant temperature in the hot legs because of the coolant temperature stratification. The methodology development was based on the findings of experimental and calculating research executed by the authors. The methodology verification was fulfilled through comparison of calculation results obtained with and without the methodology use in various operational states and modes of several WWER-1000 power units. The obtained verification results have confirmed that the use of the new methodology provides objective error decrease in determining the weighted mean coolant temperature in the primary circuit hot legs. The decrease value depends on the stratification character which is various for different objects and conditions.

  17. Verification results of methodology for determining the weighted mean coolant temperature in the primary circuit hot legs of WWER-1000 reactor plants

    Energy Technology Data Exchange (ETDEWEB)

    Saunin, Yuri V.; Dobrotvorski, Alexander N.; Semenikhin, Alexander V.; Korolev, Alexander S. [JSC ' ' Atomtechenergo' ' , Novovoronezh (Russian Federation). Novovoronezh Filial ' ' Novovoronezhatomtechenergo' ' ; Ryasny, Sergei I. [JSC ' ' Atomtechenergo' ' , Moscow (Russian Federation)

    2017-09-15

    The JSC ''Atomtechenergo'' experts have developed a new methodology for determining the weighted mean coolant temperature in the primary circuit hot legs of WWER-1000 reactor plants. The necessity for developing the new methodology was determined by the need to decrease the calculation error of the weighted mean coolant temperature in the hot legs because of the coolant temperature stratification. The methodology development was based on the findings of experimental and calculating research executed by the authors. The methodology verification was fulfilled through comparison of calculation results obtained with and without the methodology use in various operational states and modes of several WWER-1000 power units. The obtained verification results have confirmed that the use of the new methodology provides objective error decrease in determining the weighted mean coolant temperature in the primary circuit hot legs. The decrease value depends on the stratification character which is various for different objects and conditions.

  18. EP 1000 -The European Passive Plant

    International Nuclear Information System (INIS)

    Cummins, Ed; Oyarzabal, Mariano; Saiu, Gianfranco

    1998-01-01

    A group of European utilities, along with Westinghouse and its industrial partner GENESI (an Italian consortium including ANSALDO and FIAT) initiated a program to evaluate Westinghouse passive nuclear plant technology for application in Europe. The European utility group consisted of: Agrupacion electrica para al Desarrollo Technologico Nuclear (DTN), Spain; Electricite de France; ENEL, SpA., Italy; IVO Power Engineering, Ltd., Finland; Scottish Nuclear Limited (acting for itself on behalf of Nuclear Electric plc, U.K.; Tractebel Energy Engineering, Belgium; UAK (represented by NOK-Beznau), Switzerland; and Vattenfall AB, Ringhals, Sweden. The European Passive Plant (EPP) program, which began in 1994, is an evaluation of the Westinghouse 600 MWe AP 600 and 1000 MWe Simplified Pressurized Water Reactor (SPWR) designs in meeting the European Utility Requirements (EUR), and where necessary, modifying the design to achieve compliance. Phase 1 or the EPP program was completed and included the two major tasks of evaluating the effect of the EUR on the Westinghouse nuclear island and developing the EP 1000, a 1000 MWe passive plant reference design that conforms to the EUR and would be licensable in Europe. The EP 1000 closely follows the Westinghouse SPWR design for safety systems and containment and the AP 600 design for auxiliary systems. It also includes features that where required to meet the EUR and key European licensing requirements. The primary circuit of the EP 1000 retains most of the general features of the current-day designs, but some evolutionary features to enhance reliability, simplicity of operation, ease of maintenance, and plant safety have been incorporated into the design. The core, reactor vessel, and reactor internals of the EP 1000 are similar to those of currently operating Westinghouse PWR plants, but several new features are included to enhance the performance characteristics. The basic EP 1000 safety philosophy is based on use of inherent

  19. Magnetic Levitation Force Measurement System at Any Low Temperatures From 20 K To 300 K

    Science.gov (United States)

    Celik, Sukru; Guner, S. Baris; Coskun, Elvan

    2015-03-01

    Most of the magnetic levitation force measurements in previous studies were performed at liquid nitrogen temperatures. For the levitation force of MgB2 and iron based superconducting samples, magnetic levitation force measurement system is needed. In this study, magnetic levitation force measurement system was designed. In this system, beside vertical force versus vertical motion, lateral and vertical force versus lateral motion measurements, the vertical force versus temperature at the fixed distance between permanent magnet PM - superconducting sample SS and the vertical force versus time measurements were performed at any temperatures from 20 K to 300 K. Thanks to these measurements, the temperature dependence, time dependence, and the distance (magnetic field) and temperature dependences of SS can be investigated. On the other hand, the magnetic stiffness MS measurements can be performed in this system. Using the measurement of MS at different temperature in the range, MS dependence on temperature can be investigated. These measurements at any temperatures in the range help to the superconductivity properties to be characterized. This work was supported by TUBTAK-the Scientific and technological research council of Turkey under project of MFAG - 110T622. This system was applied to the Turkish patent institute with the Application Number of 2013/13638 on 22/11/2013.

  20. Radiation measurements by pn junction InSb detector at the temperature from 4.2 K to 115 K

    International Nuclear Information System (INIS)

    Kanno, Ikuo; Yoshihara, Fumiki; Nouchi, Ryo; Sugiura, Osamu; Murase, Yasuhiro; Nakamura, Tatsuya; Katagiri, Masaki

    2003-01-01

    We fabricated the pn junction-type detectors on a p-type InSb substrate. Both sides of the InSb substrate were etched using a mixture of nitric and lactic acids. On the top side surface, Sn and Al were deposited by heat evaporation and then the Sn was diffused into the p-type InSb by lamp annealing and resulted in the n-type layer. Based on the confirmation of the performance of the InSb detector at temperatures of 0.5 K and 4.2 K, we concentrated on the measurement of alpha particles by the pm junction-type InSb detectors at higher operating temperatures of up to 115 K. The InSb detector showed a wide temperature operating range. We can conclude that all of the voltage was induced slowly by the holes at 4.2 K and mainly as a result of electrons at 77 K. (T. Tanaka)

  1. 7 CFR 1000.91-1000.92 - [Reserved

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 9 2010-01-01 2009-01-01 true [Reserved] 1000.91-1000.92 Section 1000.91-1000.92 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing... Miscellaneous Provisions §§ 1000.91-1000.92 [Reserved] ...

  2. New 1.5 K cryogenerator for radioastronomical use

    International Nuclear Information System (INIS)

    Marechal, J.C.; Pernot, J.C.; Encrenaz, P.

    1986-01-01

    A closed-cycle refrigerator has been developed to permit the operation of SIS (superconductor/insulator/superconductor) receivers on radiotelescopes located at remote sites. Operating temperature is well below 2 K, mean time between failures is more than 1000 hours, and the unit is powerful enough to accept an array of SIS detectors at millimeter and submillimeter wavelengths. Studies of the long- and short-term stability show both to be very good. The output of the third stage of the four-stage unit is at 4.4 K with less than 10 to the -3 K of noise and unmeasurably small long-term drift; the fourth stage output is at 1.6 K with less than 10 to the -2 K of noise and less than 2 x 10 to the -2 K of long-term drift. The mixer operates at 1.8 K. An automatic valve is being developed for stable control of equilibrium temperatures when power requirements are close to the maximum power available

  3. 130 LPW 1000 Lm Warm White LED for Illumination

    Energy Technology Data Exchange (ETDEWEB)

    Soer, Wouter [Philips Lumileds Lighting Company LLC, San Jose, CA (United States)

    2012-12-21

    An illumination-grade warm-white LED, having correlated color temperature (CCT) between 2700 and 3500 K and capable of producing 1000 lm output at over 130 lm/W at room temperature, has been developed in this program. The high-power warm-white LED is an ideal source for use in indoor and outdoor lighting applications. Over the two year period, we have made the following accomplishments: • Developed a low-cost high-power white LED package and commercialized a series of products with CCT ranging from 2700 to 5700 K under the product name LUXEON M; • Demonstrated a record efficacy of 124.8 lm/W at a flux of 1023 lm, CCT of 3435 K and color rendering index (CRI) over 80 at room temperature in the productized package; • Demonstrated a record efficacy of 133.1 lm/W at a flux of 1015 lm, CCT of 3475 K and CRI over 80 at room temperature in an R&D package. The new high-power LED package is a die-on-ceramic surface mountable LED package. It has four 2 mm2 InGaN pump dice, flip-chip attached to a ceramic submount in a 2x2 array configuration. The submount design utilizes a design approach that combines a high-thermal- conductivity ceramic core for die attach and a low-cost and low-thermal-conductivity ceramic frame for mechanical support and as optical lens carrier. The LED package has a thermal resistance of less than 1.25 K/W. The white LED fabrication also adopts a new batch level (instead of die-by-die) phosphor deposition process with precision layer thickness and composition control, which provides not only tight color control, but also low cost. The efficacy performance goal was achieved through the progress in following key areas: (1) high-efficiency royal blue pump LED development through active region design and epitaxial growth quality improvement (funded by internal programs); (2) improvement in extraction efficiency from the LED package through improvement of InGaN-die-level and package-level optical extraction efficiency; and (3) improvement in phosphor

  4. Spin trapping of radicals formed in gamma-irradiated methanol: effect of the irradiation temperature from 77K to 300K

    International Nuclear Information System (INIS)

    Schlick, S.; Kevan, L.

    1976-01-01

    The neutral radicals formed in gamma-irradiated methanol were studied by spin trapping with phenyl-t-butylnitrone (PBN) in an attempt to probe the primary neutral radicals formed. In the temperature range from approximately 157 K to 300 K both CH 2 OH and CH 3 O spin adducts are observed and their limiting ratio at high PBN concentrations is CH 2 OH/CH 3 O=1.5 over this temperature range. Below approximately 157 K this ratio increases exponentially with decreasing temperature with an apparent activation energy of 5.8 kJ/mole (1.4 kcal/mole); this is consistent with the finding that only CH 2 OH radicals are formed by gamma radiolysis at 77 K. Several possible models for the primary neutral radicals formed in gamma-irradiated methanol and their subsequent reactions as a function of irradiation temperature are discussed. It is suggested that the primary radical formation mechanisms are similar in the gas and liquid phases and become temperature dependent when molecular motion is arrested in the solid. (Auth.)

  5. Electrical conductivity of molten SnCl2 at temperature as high as 1314 K

    International Nuclear Information System (INIS)

    Salyulev, Alexander B.; Potapov, Alexei M.

    2015-01-01

    The electrical conductivity of molten SnCl 2 was measured in a wide temperature range (ΔT=763 K), from 551 K to temperature as high as 1314 K, that is, 391 above the boiling point of the salt. The specific electrical conductance was found to reach its maximum at 1143 K, after that it decreases with the temperature rising.

  6. Experiment and operation of a LHCD-35 kV/2.8 MW/1000 s high-voltage power supply on HT-7 tokamak

    International Nuclear Information System (INIS)

    Huang Yiyun

    2002-01-01

    A-35 kV/2.8 MW/1000s high-voltage power supply (HVPS) for HT-7 superconducting tokamak has been built successfully. The HVPS is scheduled to run on a 2.45 GHz/1 MW lower hybrid current drive (LHCD) system of HT-7 superconducting tokamak before the set-up of HT-7 superconducting tokamak in 2003. The HVPS has a series of advantages such as good steady and dynamic response, logical computer program controlling the HVPS without any fault, operational panel and experimental board for data acquisition, which both are grounded distinctively in a normative way to protect the main body of HVPS along with its attached equipment from dangers. Electric power cables and other control cables are disposed reasonably, to prevent signals from magnetic interference and ensure the precision of signal transfer. The author introduced the experiment and operation of a 35 kV/2.8 MW/1000 s HVPS for 2.45 GHz/1 MW LHCD system. The reliability and feasibility of the HVPS has been demonstrated in comparison with experimental results of original design and simulation data

  7. Critical current measurements of high-temperature superconducting short samples at a wide range of temperatures and magnetic fields

    Science.gov (United States)

    Ma, Hongjun; Liu, Huajun; Liu, Fang; Zhang, Huahui; Ci, Lu; Shi, Yi; Lei, Lei

    2018-01-01

    High-Temperature Superconductors (HTS) are potential materials for high-field magnets, low-loss transmission cables, and Superconducting Magnetic Energy Storage (SMES) due to their high upper critical magnetic field (Hc2) and critical temperature (Tc). The critical current (Ic) of HTS, which is one of the most important parameters for superconductor application, depends strongly on the magnetic fields and temperatures. A new Ic measurement system that can carry out accurate Ic measurement for HTS short samples with various temperatures (4.2-80 K), magnetic fields (0-14 T), and angles of the magnetic field (0°-90°) has been developed. The Ic measurement system mainly consists of a measurement holder, temperature-control system, background magnet, test cryostat, data acquisition system, and DC power supply. The accuracy of temperature control is better than ±0.1 K over the 20-80 K range and ±0.05 K when measured below 20 K. The maximum current is over 1000 A with a measurement uncertainty of 1%. The system had been successfully used for YBa2Cu3O7-x(YBCO) tapes Ic determination with different temperatures and magnetic fields.

  8. Critical current measurements of high-temperature superconducting short samples at a wide range of temperatures and magnetic fields.

    Science.gov (United States)

    Ma, Hongjun; Liu, Huajun; Liu, Fang; Zhang, Huahui; Ci, Lu; Shi, Yi; Lei, Lei

    2018-01-01

    High-Temperature Superconductors (HTS) are potential materials for high-field magnets, low-loss transmission cables, and Superconducting Magnetic Energy Storage (SMES) due to their high upper critical magnetic field (H c2 ) and critical temperature (T c ). The critical current (I c ) of HTS, which is one of the most important parameters for superconductor application, depends strongly on the magnetic fields and temperatures. A new I c measurement system that can carry out accurate I c measurement for HTS short samples with various temperatures (4.2-80 K), magnetic fields (0-14 T), and angles of the magnetic field (0°-90°) has been developed. The I c measurement system mainly consists of a measurement holder, temperature-control system, background magnet, test cryostat, data acquisition system, and DC power supply. The accuracy of temperature control is better than ±0.1 K over the 20-80 K range and ±0.05 K when measured below 20 K. The maximum current is over 1000 A with a measurement uncertainty of 1%. The system had been successfully used for YBa 2 Cu 3 O 7-x (YBCO) tapes I c determination with different temperatures and magnetic fields.

  9. High-temperature thermopower of some REIn3 compounds

    International Nuclear Information System (INIS)

    Kletowski, Z.; Resel, R.

    1995-01-01

    The temperature dependences of the thermopower of six REIn 3 compounds (RE=La, Pr, Gd, Dy, Er and Lu) were measured in the temperature range up to 1000 K. The observed changes in the slopes of the temperature versus thermopower curves for all the investigated compounds are interpreted as originating from a special shape of the density of states (DOS) near the Fermi energy, E F . ((orig.))

  10. A study of the reaction Li+HCl by the technique of time-resolved laser-induced fluorescence spectroscopy of Li (2 2PJ-2 2S1/2, λ=670.7 nm) between 700 and 1000 K

    Science.gov (United States)

    Plane, John M. C.; Saltzman, Eric S.

    1987-10-01

    A kinetic study is presented of the reaction between lithium atoms and hydrogen chloride over the temperature range 700-1000 K. Li atoms are produced in an excess of HCl and He bath gas by pulsed photolysis of LiCl vapor. The concentration of the metal atoms is then monitored in real time by the technique of laser-induced fluorescence of Li atoms at λ=670.7 nm using a pulsed nitrogen-pumped dye laser and box-car integration of the fluorescence signal. Absolute second-order rate constants for this reaction have been measured at T=700, 750, 800, and 900 K. At T=1000 K the reverse reaction is sufficiently fast that equilibrium is rapidly established on the time scale of the experiment. A fit of the data between 700 and 900 K to the Arrhenius form, with 2σ errors calculated from the absolute errors in the rate constants, yields k(T)=(3.8±1.1)×10-10 exp[-(883±218)/T] cm3 molecule-1 s-1. This result is interpreted through a modified form of collision theory which is constrained to take account of the conservation of total angular momentum during the reaction. Thereby we obtain an estimate for the reaction energy threshold, E0=8.2±1.4 kJ mol-1 (where the error arises from uncertainty in the exothermicity of the reaction), in very good agreement with a crossed molecular beam study of the title reaction, and substantially lower than estimates of E0 from both semiempirical and ab initio calculations of the potential energy surface.

  11. Experimental study of temperature sensor for an ocean-going liquid hydrogen (LH2) carrier

    Science.gov (United States)

    Nakano, A.; Shimazaki, T.; Sekiya, M.; Shiozawa, H.; Aoyagi, A.; Ohtsuka, K.; Iwakiri, T.; Mikami, Z.; Sato, M.; Kinoshita, K.; Matsuoka, T.; Takayama, Y.; Yamamoto, K.

    2018-04-01

    The prototype temperature sensors for an ocean-going liquid hydrogen (LH2) carrier were manufactured by way of trial. All of the sensors adopted Platinum 1000 (PT-1000) resistance thermometer elements. Various configurations of preproduction temperature sensors were tested in AIST's LH2 test facility. In the experiments, a PT-1000 resistance thermometer, calibrated at the National Metrology Institute of Japan at AIST, was used as the standard thermometer. The temperatures measured by the preproduction sensors were compared with the temperatures measured by the standard thermometer, and the measurement accuracy of the temperature sensors in LH2 was investigated and discussed. It was confirmed that the measurement accuracies of the preproduction temperature sensors were within ±50 mK, which is the required measurement accuracy for a technical demonstration ocean-going LH2 carrier.

  12. An opportunity for capacity up-rating of 1000 MW steam turbine plant in Kozloduy NPP

    International Nuclear Information System (INIS)

    Popov, D.

    2005-01-01

    In connection with earlier and forced decommissioning of the Kozloduy NPP units 1 - 4, an alternative has to be found in order to substitute these capacities. As a reasonable options, capacity up-rating of 1000 MW steam turbine plants without nuclear reactor thermal capacity increase, is investigated in the present study. The cooling water for these units is delivered by Danube river. The cooling water temperatures substantially decrease during the winter months. These changes create an opportunity for steam back end pressure reduction. It was found that when the cooling water temperature decreases from 15 0 C to 3 0 C, the steam back end pressure is on the decrease of from 3.92 kPa to 2.3 kPa. As a result capacity of the plant could be raised up to 50 MW without any substantial equipment and systems change

  13. Investigation of cool down processes in a NPP turbine of the K-1000-60/1500 type

    International Nuclear Information System (INIS)

    Pereverzev, D.A.; Lebedev, A.G.; Palej, V.A.

    1985-01-01

    Methods of mathematical simulation were used to investigate cooling-off dynamics of separate NPP turbine parts of the K-1000-60/1500 type during shutdowns of different duration. Investigations indicated that a flange section of horizontal external casing joint in the steam inlet zone of the intermediate pressure casing is a main place limiting duration of turbine starting regime. When strengthening thermal protection of branch pipes, turbine start-up time (after shutdown during 72-168 h) can be reduced by 0.25-0.3 h; if also pick-ups are isolated than reduction of start-up duration will constitute 0.5-0.7 h. During shutdowns of shorter duration all critical assemblies will not limit in practice time of starting regime

  14. The effective temperatures and colours of G and K stars

    International Nuclear Information System (INIS)

    Bell, R.A.; Gustafsson, B.

    1989-01-01

    Temperature scales are found for G and K dwarf and giant stars, using new tables of synthetic infrared colours as well as the infrared flux ratio method. The temperatures of 95 individual stars are given. The colours are presented for grids of flux constant, line blanketed models. One grid has been published previously, as have some colours for the visible region of the spectrum. The models of this grid are in the range 4000 K eff < 6000 K, 0.75 < log g < 3.00, - 3.0 < [A/H] < 0.0. A grid of dwarf models, with the same temperature and abundance range but with 3.75 < log g < 4.5 is also used. The colours are computed from two series of overlapping synthetic spectra, which have been calculated with a resolution of 0.1 A between 3000 and 12 000 A and 1.0 A between 0.9 and 6.0 μm. (author)

  15. STELLAR DIAMETERS AND TEMPERATURES. II. MAIN-SEQUENCE K- AND M-STARS

    Energy Technology Data Exchange (ETDEWEB)

    Boyajian, Tabetha S.; McAlister, Harold A.; Jones, Jeremy; White, Russel; Henry, Todd; Gies, Douglas; Jao, Wei-Chun; Parks, J. Robert [Center for High Angular Resolution Astronomy and Department of Physics and Astronomy, Georgia State University, P.O. Box 4106, Atlanta, GA 30302-4106 (United States); Von Braun, Kaspar; Kane, Stephen R.; Ciardi, David [NASA Exoplanet Science Institute, California Institute of Technology, MC 100-22, Pasadena, CA 91125 (United States); Van Belle, Gerard [Lowell Observatory, Flagstaff, AZ 86001 (United States); Ten Brummelaar, Theo A.; Schaefer, Gail; Sturmann, Laszlo; Sturmann, Judit [The CHARA Array, Mount Wilson Observatory, Mount Wilson, CA 91023 (United States); Muirhead, Philip S. [Department of Astronomy, California Institute of Technology, 1200 East California Boulevard, MC 249-17, Pasadena, CA 91125 (United States); Lopez-Morales, Mercedes [Institut de Ciencies de L' Espai (CSIC-IEEC), E-08193 Bellaterra (Spain); Ridgway, Stephen [National Optical Astronomy Observatory, P.O. Box 26732, Tucson, AZ 85726-6732 (United States); Rojas-Ayala, Barbara [Department of Astrophysics, Division of Physical Sciences, American Museum of Natural History, Central Park West at 79th Street, New York, NY 10024 (United States); and others

    2012-10-01

    We present interferometric angular diameter measurements of 21 low-mass, K- and M-dwarfs made with the CHARA Array. This sample is enhanced by adding a collection of radius measurements published in the literature to form a total data set of 33 K-M-dwarfs with diameters measured to better than 5%. We use these data in combination with the Hipparcos parallax and new measurements of the star's bolometric flux to compute absolute luminosities, linear radii, and effective temperatures for the stars. We develop empirical relations for {approx}K0 to M4 main-sequence stars that link the stellar temperature, radius, and luminosity to the observed (B - V), (V - R), (V - I), (V - J), (V - H), and (V - K) broadband color index and stellar metallicity [Fe/H]. These relations are valid for metallicities ranging from [Fe/H] = -0.5 to +0.1 dex and are accurate to {approx}2%, {approx}5%, and {approx}4% for temperature, radius, and luminosity, respectively. Our results show that it is necessary to use metallicity-dependent transformations in order to properly convert colors into stellar temperatures, radii, and luminosities. Alternatively, we find no sensitivity to metallicity on relations we construct to the global properties of a star omitting color information, e.g., temperature-radius and temperature-luminosity. Thus, we are able to empirically quantify to what order the star's observed color index is impacted by the stellar iron abundance. In addition to the empirical relations, we also provide a representative look-up table via stellar spectral classifications using this collection of data. Robust examinations of single star temperatures and radii compared to evolutionary model predictions on the luminosity-temperature and luminosity-radius planes reveal that models overestimate the temperatures of stars with surface temperatures <5000 K by {approx}3%, and underestimate the radii of stars with radii <0.7 R{sub Sun} by {approx}5%. These conclusions additionally

  16. Two-stage high frequency pulse tube refrigerator with base temperature below 10 K

    Science.gov (United States)

    Chen, Liubiao; Wu, Xianlin; Liu, Sixue; Zhu, Xiaoshuang; Pan, Changzhao; Guo, Jia; Zhou, Yuan; Wang, Junjie

    2017-12-01

    This paper introduces our recent experimental results of pulse tube refrigerator driven by linear compressor. The working frequency is 23-30 Hz, which is much higher than the G-M type cooler (the developed cryocooler will be called high frequency pulse tube refrigerator in this paper). To achieve a temperature below 10 K, two types of two-stage configuration, gas coupled and thermal coupled, have been designed, built and tested. At present, both types can achieve a no-load temperature below 10 K by using only one compressor. As to gas-coupled HPTR, the second stage can achieve a cooling power of 16 mW/10K when the first stage applied a 400 mW heat load at 60 K with a total input power of 400 W. As to thermal-coupled HPTR, the designed cooling power of the first stage is 10W/80K, and then the temperature of the second stage can get a temperature below 10 K with a total input power of 300 W. In the current preliminary experiment, liquid nitrogen is used to replace the first coaxial configuration as the precooling stage, and a no-load temperature 9.6 K can be achieved with a stainless steel mesh regenerator. Using Er3Ni sphere with a diameter about 50-60 micron, the simulation results show it is possible to achieve a temperature below 8 K. The configuration, the phase shifters and the regenerative materials of the developed two types of two-stage high frequency pulse tube refrigerator will be discussed, and some typical experimental results and considerations for achieving a better performance will also be presented in this paper.

  17. A 13 kA current lead, measuring 1.5 m in length. The lower part consists of a high-temperature superconductor (Bi-2223), operating at between 50 K and 4.5 K, while the heat-exchanger upper part allows the current to be brought from room temperature to 50 K.

    CERN Multimedia

    2004-01-01

    A 13 kA current lead, measuring 1.5 m in length. The lower part consists of a high-temperature superconductor (Bi-2223), operating at between 50 K and 4.5 K, while the heat-exchanger upper part allows the current to be brought from room temperature to 50 K.

  18. Electrical conductivity of molten SnCl{sub 2} at temperature as high as 1314 K

    Energy Technology Data Exchange (ETDEWEB)

    Salyulev, Alexander B.; Potapov, Alexei M. [Ural Branch of RAS, Ekaterinburg (Russian Federation). Inst. of High-Temperature Electrochemistry

    2015-07-01

    The electrical conductivity of molten SnCl{sub 2} was measured in a wide temperature range (ΔT=763 K), from 551 K to temperature as high as 1314 K, that is, 391 above the boiling point of the salt. The specific electrical conductance was found to reach its maximum at 1143 K, after that it decreases with the temperature rising.

  19. A tentative record of the last 1,000 years of Greenland temperature from occluded air in the GISP2 ice core

    Science.gov (United States)

    Kobashi, T.; Severinghaus, J. P.; Barnola, J.; Kawamura, K.; Beaudette, R.

    2005-12-01

    Ice borehole temperature inversion has been used to reconstruct Greenland surface temperature during the last millennium (Dahl-Jensen et al, Science, 1998). However, this technique does not preserve high frequencies because of diffusion of heat in the ice. Here, we present a tentative reconstruction of the past 1,000 years of central Greenland temperature using nitrogen and argon isotopes from occluded air in the GISP2 ice core. This technique preserves decadal-to-centennial-scale temperature variations and complements the borehole technique. Nitrogen and argon isotopes in the porous snow layer (~80m) experience two isotopic fractionations by gravitation and temperature gradients (ΔT) between the top and bottom of the snow layer. The simultaneous analysis of argon and nitrogen isotopes allows us to separate these two effects, and obtain a history of ΔT in the layer. To a first approximation, ΔT change on decadal to centennial time scales is a surface temperature history because the heat conductivity of snow is much smaller than that of ice, and the heat capacity of the ice sheet is quite large. The preliminary ΔT history (20-year interval) shows a Medieval Warm Period in the 11th to 12th centuries and the Little Ice Age in the 15th to 19th centuries. Furthermore, the record shows a clear similarity with the Be-10 record (a proxy for solar activity) with Wolf, Sporer, Maunder, and Dalton minima clearly seen in the cold periods. This finding is consistent with the hypothesis that solar activity influenced Greenland temperature during the past 1000 years.

  20. Effect of the Solvent Temperatures on Dynamics of Serine Protease Proteinase K

    Directory of Open Access Journals (Sweden)

    Peng Sang

    2016-02-01

    Full Text Available To obtain detailed information about the effect of the solvent temperatures on protein dynamics, multiple long molecular dynamics (MD simulations of serine protease proteinase K with the solute and solvent coupled to different temperatures (either 300 or 180 K have been performed. Comparative analyses demonstrate that the internal flexibility and mobility of proteinase K are strongly dependent on the solvent temperatures but weakly on the protein temperatures. The constructed free energy landscapes (FELs at the high solvent temperatures exhibit a more rugged surface, broader spanning range, and higher minimum free energy level than do those at the low solvent temperatures. Comparison between the dynamic hydrogen bond (HB numbers reveals that the high solvent temperatures intensify the competitive HB interactions between water molecules and protein surface atoms, and this in turn exacerbates the competitive HB interactions between protein internal atoms, thus enhancing the conformational flexibility and facilitating the collective motions of the protein. A refined FEL model was proposed to explain the role of the solvent mobility in facilitating the cascade amplification of microscopic motions of atoms and atomic groups into the global collective motions of the protein.

  1. Thermometry using 1/8 W carbon resistors in a temperature region around 10 mK

    International Nuclear Information System (INIS)

    Kobayasi, S.; Shinohara, M.; Ono, K.

    1976-01-01

    The resistance-temperature characteristics of 1/8 W carbon resistors of grade ERC-18SG, manufactured by Matsushita, with the nominal values of 48, 82, 100, 220 and 330 Ω have been measured in the region 4.2 K to 25 mK and their application as thermometers in this region is confirmed. For the 82 Ω resistor, measurements were taken at temperatures below 10mK. The temperature dependence of the resistance was found to be linear on the log-log plot over a wide range below 50 mK. The sensitivity remains finite even at 6 mK, but below 10 mK rapid measurements were prevented by a considerable increase in the thermal relaxation time. Measurement of the characteristics of several 100 Ω resistors from two different sets showed that resistors from the same set separate into two groups with different characteristics. This become appreciable at temperatures below 4.2 K, so it is difficult to predict the behaviour of Matsushite resistors below 4.2 K from the characteristics at higher temperatures. (author)

  2. Dynamic temperature measurements with embedded optical sensors.

    Energy Technology Data Exchange (ETDEWEB)

    Dolan, Daniel H.,; Seagle, Christopher T; Ao, Tommy

    2013-10-01

    This report summarizes LDRD project number 151365, \\Dynamic Temperature Measurements with Embedded Optical Sensors". The purpose of this project was to develop an optical sensor capable of detecting modest temperature states (<1000 K) with nanosecond time resolution, a recurring diagnostic need in dynamic compression experiments at the Sandia Z machine. Gold sensors were selected because the visible re ectance spectrum of gold varies strongly with temperature. A variety of static and dynamic measurements were performed to assess re ectance changes at di erent temperatures and pressures. Using a minimal optical model for gold, a plausible connection between static calibrations and dynamic measurements was found. With re nements to the model and diagnostic upgrades, embedded gold sensors seem capable of detecting minor (<50 K) temperature changes under dynamic compression.

  3. In-situ temperature calibration below 1 K using the μ+ Knight shift in CMN

    International Nuclear Information System (INIS)

    Heffner, R.H.; Le, L.P.; Amato, A.; Baines, C.

    1996-01-01

    The authors present μ + paramagnetic shift measurements between 12 K and about 65 mK in cerium magnesium nitrate (CMN) to investigate its utility as an in-situ temperature calibration source for low temperature μSR experiments. CMN is a salt which exhibits Curie-law susceptibility to temperatures as low as 5 mK. The μ + Knight shift is measured to be (1.46 ± 0.03) x 10 -3 /T + (0.004 ± 0.02) x 10 -3 , corresponding to a transferred hyperfine field of -28.5 kOe/μ B

  4. Emission characteristics of uranium hexafluoride at high temperatures

    International Nuclear Information System (INIS)

    Krascella, N.L.

    1976-01-01

    An experimental study was conducted to ascertain the spectral characteristics of uranium hexafluoride (UF 6 ) and possible UF 6 thermal decomposition products as a function of temperature and pressure. Relative emission measurements were made for UF 6 /Argon mixtures heated in a plasma torch over a range of temperatures from 800 to about 3600 0 K over a wavelength range from 80 to 600 nm. Total pressures were varied from 1 to approximately 1.7 atm. Similarly absorption measurements were carried out in the visible region from 420 to 580 nm over a temperature range from about 1000 to 1800 0 K. Total pressure for these measurements was 1.0 atm

  5. High-temperature thermoelectric behavior of lead telluride

    Indian Academy of Sciences (India)

    The central problem in thermoelectric material research is the selection of ... temperature range (400–1000 K), and bismuth telluride-based materials .... parent from the results that band non-parabolicity has a significant effect on the .... M P Singh thankfully acknowledges financial assistance from the Council of Scien-.

  6. Measurement of high temperature elastic moduli of an 18Cr-9Ni-2.95 Cu-0.58 Nb-0.1C (Wt %) austenitic stainless steel

    Science.gov (United States)

    Tripathy, Haraprasanna; Hajra, Raj Narayan; Sudha, C.; Raju, S.; Saibaba, Saroja

    2018-04-01

    The Young's modulus (E) and Shear modulus (G) of an indigenously developed 18Cr-9Ni-0.1C-2.95 Cu-0.58Nb (wt %) austenitic stainless steel has been evaluated in the temperature range 298 K to 1273 K (25 °C to 1000 °C), using Impulse excitation technique (IET). The Bulk modulus (K) and the poison's ratio have been estimated from the measured values of E and G. It is observed that the elastic constants (E, G and K) are found to decrease in a nonlinear fashion with increase in temperature. The Cu precipitation is found to influence the elastic moduli of the steel in the cooling cycle. The observed elastic moduli are fitted to 3rd order polynomial equations in order to describe the temperature dependence of E, G, K moduli in the temperature range 298-1273 K (25 °C to 1000 °C). The room temperature values of E,G and K moduli is found to be 207, 82 and 145 GPa respectively for the present steel.

  7. Electrical conductivity of molten CdCl2 at temperatures as high as 1474 K

    International Nuclear Information System (INIS)

    Salyulev, Alexander B.; Potapov, Alexei M.

    2016-01-01

    The electrical conductivity of molten CdCl 2 was measured across a wide temperature range (ΔT=628 K), from 846 K to as high as 1474 K, i.e. 241 above the normal boiling point of the salt. In previous studies, a maximum temperature of 1201 K was reached, this being 273 lower than in the present work. The activation energy of electrical conductivity was calculated.

  8. Future market relevance of CHP installations with electrical ratings from 1 to 1000 kW

    International Nuclear Information System (INIS)

    Eicher, H.; Rigassi, R.

    2003-12-01

    This report for the Swiss Federal Office of Energy (SFOE) discusses the future market relevance of combined heat and power (CHP) installations with electrical ratings from 1 to 1000 kW. Developments over the past ten years are reviewed. Important reductions in the price of motor-driven CHP units and the price of the electrical power produced are noted and commented on. The technical market potential of CHP units and the degree to which this potential has been implemented are commented on. Work done, including CHP implementation in the industrial, commercial and residential areas, is commented on. Future developments both in the technical area as well as in commercial areas are commented on. Micro-gas-turbine based CHP systems are also discussed, as are fuel-cell based systems in both the higher and lower capacity power generation area. The prospects for CHP systems in general in the electricity generation area are discussed

  9. Dielectric properties of some cadmium and mercury amino alcohol complexes at low temperatures

    Directory of Open Access Journals (Sweden)

    ALAA E. ALI

    2002-12-01

    Full Text Available The dielectric properties of some cadmium and mercury amino alcohol complexes were studied within the temperature range of 100–300 K at the frequencies of 100, 300 and 1000 kHz. The polarization mechanisms are suggested and the dependence of both e and tg d on both temperature and frequency are analyzed. The analysis of the data reveals semi-conducting features based mainly on the hopping mechanism.

  10. High-capacity NO2 denuder systems operated at various temperatures (298-473 K).

    Science.gov (United States)

    Wolf, Jan-Christoph; Niessner, Reinhard

    2012-12-01

    In this study, we investigated several coatings for high-temperature, high-capacity, and high-efficiency denuder-based NO(2) removal, with the scope to face the harsh conditions and requirements of automotive exhaust gas sampling. As first coating, we propose a potassium iodide (KI)/polyethylene glycol coating with a high removal efficiency (ε > 98%) for about 2 h and 50 ppm NO(2) at room temperature (298 K). At elevated temperatures (423 K), the initial capacity (100 ppmh) is decreased to 15 ppmh. Furthermore, this is the first proposal of the ionic liquid methyl-butyl-imidazolium iodide ([BMIm(+)][I(-)]) as denuder coating material. At room temperature, this ionic liquid exhibits far greater capacity (300 ppmh) and NO(2) removal efficiency (ε > 99.9%) than KI. Nevertheless, KI exhibits a slightly (~10%) higher capacity at elevated temperatures than [BMIm(+)][I(-)]. Both coatings presented are suitable for applications requiring selective denuding of NO(2) at temperatures up to 423 K.

  11. Thermoelectric Properties of High-Doped Silicon from Room Temperature to 900 K

    Science.gov (United States)

    Stranz, A.; Kähler, J.; Waag, A.; Peiner, E.

    2013-07-01

    Silicon is investigated as a low-cost, Earth-abundant thermoelectric material for high-temperature applications up to 900 K. For the calculation of module design the Seebeck coefficient and the electrical as well as thermal properties of silicon in the high-temperature range are of great importance. In this study, we evaluate the thermoelectric properties of low-, medium-, and high-doped silicon from room temperature to 900 K. In so doing, the Seebeck coefficient, the electrical and thermal conductivities, as well as the resulting figure of merit ZT of silicon are determined.

  12. Electrical conductivity of molten ZnCl2 at temperature as high as 1421 K

    International Nuclear Information System (INIS)

    Salyulev, Alexander B.; Potapov, Alexei M.

    2015-01-01

    The electrical conductivity of molten ZnCl 2 was measured in a wide temperature range (ΔT=863 K) to a temperature as high as 1421 K that is 417 degrees above the boiling point of the salt. At the temperature maximum of the own vapor pressure of the salt reached several megapascals.

  13. Experimental assessment of welded joints brittle fracture on the crack arrest criterion for WWER-1000 RPV

    International Nuclear Information System (INIS)

    Blumin, A.A.; Timofeev, B.T.

    2000-01-01

    The crack arrest fracture toughness in a vessel steel used in WWER-1000 reactor, namely in steel 15Kh2NMFA and its submerged arc welded joints, produced with Sv-08KhGNMTA, Sv-12 Kh2NMFA welding wires and NF-18 M, FZ-16 A welding fluxes, is under study. Experimental studies are carried out using three heats with the chemical composition meeting the specifications. Weld specimens 100-200 mm thick are subjected to tempering according various regimes to induce the embrittlement and simulate mechanical properties (yield strength and ductile-brittle transition temperature) corresponding to those at the end of service life under neutron radiation effect. Base metal and weld properties are compared. The wide scatter is noted for experimental data on fracture toughness temperature dependences. A possibility to use the dependence of K Ia = f (T-T k ) for determining the crack arrest fracture toughness is discussed taking in account that K Ia is a stress intensity factor calculated within the frame of static fracture mechanics [ru

  14. DDG-1000 Zumwalt Class Destroyer (DDG-1000)

    Science.gov (United States)

    2015-12-01

    Selected Acquisition Report (SAR) RCS: DD-A&T(Q&A)823-197 DDG 1000 Zumwalt Class Destroyer (DDG 1000 ) As of FY 2017 President’s Budget Defense...Acquisition Management Information Retrieval (DAMIR) March 23, 2016 15:17:06 UNCLASSIFIED DDG 1000 December 2015 SAR March 23, 2016 15:17:06...Requirements Document OSD - Office of the Secretary of Defense O&S - Operating and Support PAUC - Program Acquisition Unit Cost DDG 1000 December 2015 SAR

  15. The economic and financing viability of the OPR-1000 construction at Muria Peninsula

    International Nuclear Information System (INIS)

    Moch Djoko Birmano; Mochamad Nasrullah

    2005-01-01

    The study of the economic and financing viability of the OPR-1000 construction at Muria Peninsula have been done. This study is carried out with steps as follows: updating of newest OPR-1000 technical and economic data; survey of financing sources; the calculation of electricity generation cost, electricity tariff, construction cost of OPR-1000; and calculation of OPR-1000 financing viability by using feasibility criteria such as Net Present Value (NPV), Internal Rate of Return (IRR) and capital payback period. The calculation of generation cost, electricity tariff, construction cost and financing viability criteria (IRR, NPV, Payback Period)by using KEPCO Spread Sheet. From the results of calculations how that the electricity generation cost is 4.0866 cent/kWh, while the electricity tariff is 6.6399 cent/kWh(after Value Added Tax). The total construction cost of OPR-1000 is US $4,092.09 million (included interest and financial fee, excluded initial nuclear fuel). The calculation of financing viability in base case obtained that value of IRR, NPV and Payback Period for total investment is 10.37%. US$90.52 million and 12.11 years respectively. From these results can be concluded that with the electricity tariff of 6.640 cent/kWh or 0.0664 US$/kWh, basically this project of OPR-1000 construction is very feasible and beneficial. From investment side, this project can attract investor because the rate of capital return is high enough, profit in the end of economic life is big enough and payback period is short. (author)

  16. Problems and prospects connected with development of high-temperature filtration technology at nuclear power plants equipped with VVER-1000 reactors

    Science.gov (United States)

    Shchelik, S. V.; Pavlov, A. S.

    2013-07-01

    Results of work on restoring the service properties of filtering material used in the high-temperature reactor coolant purification system of a VVER-1000 reactor are presented. A quantitative assessment is given to the effect from subjecting a high-temperature sorbent to backwashing operations carried out with the use of regular capacities available in the design process circuit in the first years of operation of Unit 3 at the Kalinin nuclear power plant. Approaches to optimizing this process are suggested. A conceptual idea about comprehensively solving the problem of achieving more efficient and safe operation of the high-temperature active water treatment system (AWT-1) on a nuclear power industry-wide scale is outlined.

  17. Heat capacity and transition behavior of sucrose by standard, fast scanning and temperature-modulated calorimetry

    Energy Technology Data Exchange (ETDEWEB)

    Magoń, A. [Department of Chemistry, University of Technology, 35-959 Rzeszów (Poland); Wurm, A.; Schick, C. [Department of Physics, University of Rostock, 18057 Rostock (Germany); Pangloli, Ph.; Zivanovic, S. [Department of Food Science and Technology, University of Tennessee, Knoxville, TN 37996 (United States); Skotnicki, M. [Department of Pharmaceutical Technology, Poznan University of Medical Sciences, 60-780 Poznań (Poland); Pyda, M., E-mail: mpyda@utk.edu [Department of Chemistry, University of Technology, 35-959 Rzeszów (Poland)

    2014-08-10

    Highlights: • Experimental, apparent heat capacity of sucrose was investigated by advanced thermal analysis. • Vibrational heat capacity of solid state was linked with a low temperature experimental heat capacity of sucrose. • Equilibrium melting parameters of sucrose were determined. • Decomposition, superheating of crystalline sucrose during melting process were presented. • TGA, DSC, TMDSC, and FSC are useful tools for characterization of sucrose. - Abstract: The heat capacity (C{sub p}) of crystalline and amorphous sucrose was determined using standard and quasi-isothermal temperature modulated differential scanning calorimetry. The results were combined with the published data determined by adiabatic calorimetry, and the C{sub p} values are now reported for the wide 5–600 K range. The experimental C{sub p} of solid sucrose at 5–300 K was used to calculate the vibrational, solid C{sub p} based on the vibrational molecular motions. The calculated solid and liquid C{sub p} together with the transition parameters for equilibrium conditions were used as references for detailed quantitative thermal analysis of crystalline and amorphous sucrose. Melting temperature (T{sub m}) of the crystalline sucrose was identified in a broad 442–465 K range with a heat of fusion of 40–46 J/mol determined at heating rates 0.5–20 K/min, respectively. The equilibrium T{sub m} and heat of fusion of crystalline sucrose were estimated at zero heating rate as T{sup o}{sub m} = 424.4 K and ΔH{sup o}{sub f} = 32 kJ/mol, respectively. The glass transition temperature (T{sub g}) of amorphous sucrose was at 331 K with a change in C{sub p} of 267 J/(mol K) as it was estimated from reversing heat capacity by quasi-isothermal TMDSC on cooling. At heating rates less than 30 K/min, thermal decomposition occurred during melting, while at extreme rate of 1000 K/s, degradation was not observed. Data obtained by fast scanning calorimetry (FSC) at 1000 K/s, showed that T{sub m} was

  18. Development of the active magnetic regenerative refrigerator operating between 77 K and 20 K with the conduction cooled high temperature superconducting magnet

    Science.gov (United States)

    Park, Inmyong; Jeong, Sangkwon

    2017-12-01

    The experimental investigation of an active magnetic regenerative refrigerator (AMRR) operating between 77 K and 20 K is discussed in this paper, with detailed energy transfer analysis. A multi-layered active magnetic regenerator (AMR) is used, which consists of four different rare earth intermetallic compounds in the form of irregular powder. Numerical simulation confirms that the AMR can attain its target operating temperature range. Magnetic field alternation throughout the AMR is generated by a high temperature superconducting (HTS) magnet. The HTS magnet is cooled by a two stage Gifford-McMahon (GM) cryocooler. Helium gas was employed as a working fluid and its oscillating flow in the AMR is controlled in accordance with the magnetic field variation. The AMR is divided into two stages and each stage has a different mass flow rate as needed to achieve the desired cooling performance. The temperature variation of the AMR during the experiment is monitored by temperature sensors installed inside the AMR. The experimental results show that the AMRR is capable of achieving no-load temperature of 25.4 K while the warm end temperature is 77 K. The performance of the AMRR is analyzed by observing internal temperature variations at cyclic steady state. Furthermore, numerical estimation of the cooling capacity and the temperature variation of the AMR are examined and compared with the experimental results.

  19. Experimental and computational investigation of temperature effects on soot mechanisms

    Directory of Open Access Journals (Sweden)

    Bi Xiaojie

    2014-01-01

    Full Text Available Effects of initial ambient temperatures on combustion and soot emission characteristics of diesel fuel were investigated through experiment conducted in optical constant volume chamber and simulation using phenomenological soot model. There are four difference initial ambient temperatures adopted in our research: 1000 K, 900 K, 800 K and 700 K. In order to obtain a better prediction of soot behavior, phenomenological soot model was revised to take into account the soot oxidation feedback on soot number density and good agreement was observed in the comparison of soot measurement and prediction. Results indicated that ignition delay prolonged with the decrease of initial ambient temperature. The heat release rate demonstrated the transition from mixing controlled combustion at high ambient temperature to premixed combustion mode at low ambient temperature. At lower ambient temperature, soot formation and oxidation mechanism were both suppressed. But finally soot mass concentration reduced with decreasing initial ambient temperature. Although the drop in ambient temperature did not cool the mean in-cylinder temperature during the combustion, it did shrink the total area of local high equivalence ratio, in which soot usually generated fast. At 700 K initial ambient temperature, soot emissions were almost negligible, which indicates that sootless combustion might be achieved at super low initial temperature operation conditions.

  20. Application of status uncertainty analysis methods for AP1000 LBLOCA calculation

    International Nuclear Information System (INIS)

    Zhang Shunxiang; Liang Guoxing

    2012-01-01

    Parameter uncertainty analysis is developed by using the reasonable method to establish the response relations between input parameter uncertainties and output uncertainties. The application of the parameter uncertainty analysis makes the simulation of plant state more accuracy and improves the plant economy with reasonable security assurance. The AP1000 LBLOCA was analyzed in this paper and the results indicate that the random sampling statistical analysis method, sensitivity analysis numerical method and traditional error propagation analysis method can provide quite large peak cladding temperature (PCT) safety margin, which is much helpful for choosing suitable uncertainty analysis method to improve the plant economy. Additionally, the random sampling statistical analysis method applying mathematical statistics theory makes the largest safety margin due to the reducing of the conservation. Comparing with the traditional conservative bounding parameter analysis method, the random sampling method can provide the PCT margin of 100 K, while the other two methods can only provide 50-60 K. (authors)

  1. Thermophysical properties of multi-wall carbon nanotube bundles at elevated temperatures up to 830 K

    International Nuclear Information System (INIS)

    Wang, Xinwei; Wang, Jianmei; Huang, Xiaopeng; Eres, Gyula

    2011-01-01

    In this paper we discuss the results of thermal transport measurements in multi-wall carbon nanotube (MWCNT) bundles at elevated temperatures. A novel generalized electrothermal technique (GET) was developed for measuring the thermal diffusivity ( ) and conductivity (k) of MWCNT bundles. The results show that the feeding current has a negligible effect on the thermal properties. The measured k is larger than the reported values for unaligned bundles, and is comparable to that of typical aligned arrays. Compared with experimental and theoretical data for individual CNTs, k of the MWCNT bundles is two to three orders of magnitude lower, suggesting that the thermal transport in CNT bundles is dominated by the thermal contact resistance of tube-to-tube junctions. The effective density for the two MWCNT bundles, which is difficult to measure using other techniques, was determined to be 116 kg/m3 and 234 kg/m3, respectively. The temperature dependences of and k at temperatures up to 830 K was obtained. slightly decreases with temperature while k exhibits a small increase with temperature up to 500 K and then decreases. For the first time, the behavior of specific heat cp(T) for CNTs above room temperature was determined. The specific heat is close to graphite at 300-400 K but is lower than that for graphite above 400 K, indicating that the behavior of phonons in MWCNT bundles is dominated by boundary scattering rather than by the three-phonon Umklapp process. The length of the mean curvature between two adjacent tube contact points in these bundles is estimated to be on the order of micrometer to millimeter. The analysis of the radiation heat loss suggests that it needs to be considered when measuring the thermophysical properties of micro/nano wires of high aspect ratios at elevated temperatures, especially for individual CNTs due to their extremely small diameter.

  2. Driving Curie temperature towards room temperature in the half-metallic ferromagnet K2Cr8O16 by soft redox chemistry.

    Science.gov (United States)

    Pirrotta, I; Fernández-Sanjulián, J; Moran, E; Alario-Franco, M A; Gonzalo, E; Kuhn, A; García-Alvarado, F

    2012-02-14

    The half-metallic ferromagnet K(2)Cr(8)O(16) with the hollandite structure has been chemically modified using soft chemistry methods to increase the average oxidation state of chromium. The synthesis of the parent material has been performed under high pressure/high temperature conditions. Following this, different redox reactions have been carried out on K(2)Cr(8)O(16). Oxidation to obtain potassium-de-inserted derivatives, K(2-x)Cr(8)O(16) (0 ≤x≤ 1), has been investigated with electrochemical methods, while the synthesis of sizeable amounts was achieved chemically by using nitrosonium tetrafluoroborate as a highly oxidizing agent. The maximum amount of extracted K ions corresponds to x = 0.8. Upon oxidation the hollandite structure is maintained and the products keep high crystallinity. The de-insertion of potassium changes the Cr(3+)/Cr(4+) ratio, and therefore the magnetic properties. Interestingly, the Curie temperature increases from ca. 175 K to 250 K, getting therefore closer to room temperature.

  3. The bimolecular reaction of radiolysis product of hydrated electron at temperature up to 473K; Reaksi bimolekular antar produk radiolisis elektron terhidrasi pada temperatur hingga 473K

    Energy Technology Data Exchange (ETDEWEB)

    Sunaryo, G R [Reactor Safety Technology Research Centre, National Atomic Energy Agency, Serpong (Indonesia)

    1996-06-01

    Rate constant from the bimolecular reaction of hydrated electron was determined by using radiolysis method. The methanol solution with concentration of 5 x 10{sup -2} dm{sup 3} mol{sup -1} was used as a scavenger of H and OH radicals. The pH was kept by adding the buffer solution of 1.0 x 10{sup -3} dm{sup 3} mol{sup -1} Na{sub 2}HPO{sub 4} + 1.0 x 10{sup 4} dm{sup 3} mol{sup -1} NaH{sub 2}PO{sub 4}. The irradiation was done by using the electron beam which come from linear accelerator 28 MeV with pulse width 10ns and dose of 80 Gy per pulse. The absorbance of hydrated electron was observed at wavelength of 824 nm. By using the kinetic equation the rate reaction constants were obtained. The bimolecular reaction of hydrated electron increase with temperature up to 423K. The activation energy was 19.3 kJ mol{sup -1} and the 2 k (298K) was 1.1 x 10{sup 10} dm{sup 3} mol{sup -1}. Then this bimolecular reaction decrease at temperature higher than 423K and the rate reaction constant at 473K almost similar with that at 298K. (author)

  4. (p, ρ, T) Properties for n-butane in the temperature range from 280 K to 380 K at pressures up to 200 MPa

    International Nuclear Information System (INIS)

    Miyamoto, H.; Uematsu, M.

    2007-01-01

    The (p, ρ, T) properties for n-butane in the compressed liquid phase were measured by means of a metal-bellows variable volumometer in the temperature range from 280 K to 380 K at pressures up to 200 MPa. The mole fraction purity of the n-butane used in the measurements was 0.9997. The expanded uncertainties (k = 2) in temperature, pressure, and density measurements have been estimated to be less than ±3 mK; 1.4 kPa (p ≤ 7 MPa), 0.06% (7 MPa 150 MPa); and 0.09%, respectively. In the region above100 MPa at T = 280 K and T = 440 K, the uncertainty in density measurements increases from 0.09% to 0.13% and 0.22%, respectively. Eight (p, ρ, T) measurements at the same temperatures and pressures as the literature values have been conducted for comparisons. In addition, comparisons of the available equations of state with the present measurements are reported

  5. Temperature control for liquid-helium cryostats below 4.2 K

    International Nuclear Information System (INIS)

    Escorne, M.; Mauger, A.

    1983-01-01

    We report the operational characteristics of a membrane type of manostat and of a throttle valve system which we have constructed to regulate the pressure P above the liquid-helium bath. The choice of the manostat rather than the other device depends on the nature of the experiments to be performed: in the membrane type of manostat, the temperature is determined with an accuracy limited by the fluctuations ΔT around the mean value T. With throttle valves, the accuracy is limited by the drift of T in time. The performance of both devices prove to be sufficiently good as they stand, since the departure from T in the course of the experiments is lower than 10 -2 K in the whole range 1.4< T<4.2 K, being well inside this limit below 2 K. The need for expensive and complex electronic regulations to improve the temperature control is thus exceptional

  6. 1000–ton testing machine for cyclic fatigue tests of materials at liquid nitrogen temperatures

    Energy Technology Data Exchange (ETDEWEB)

    Khitruk, A. A.; Klimchenko, Yu. A.; Kovalchuk, O. A.; Marushin, E. L.; Mednikov, A. A.; Nasluzov, S. N.; Privalova, E. K.; Rodin, I. Yu.; Stepanov, D. B.; Sukhanova, M. V. [The D.V. Efremov Scientific Research Institute of Electrophysical Apparatus (NIIEFA), 3 Doroga na Metallostroy, Metallostroy, Saint Petersburg 196641 (Russian Federation)

    2014-01-29

    One of the main tasks of superconductive magnets R and D is to determine the mechanical and fatigue properties of structural materials and the critical design elements in the cryogenic temperature range. This paper describes a new facility built based on the industrial 1000-ton (10 MN) testing machine Schenk PC10.0S. Special equipment was developed to provide the mechanical and cyclic tensile fatigue tests of large-scale samples at the liquid nitrogen temperature and in a given load range. The main feature of the developed testing machine is the cryostat, in which the device converting a standard compression force of the testing machine to the tensile force affected at the test object is placed. The control system provides the remote control of the test and obtaining, processing and presentation of test data. As an example of the testing machine operation the test program and test results of the cyclic tensile fatigue tests of fullscale helium inlet sample of the PF1 coil ITER are presented.

  7. 1000–ton testing machine for cyclic fatigue tests of materials at liquid nitrogen temperatures

    International Nuclear Information System (INIS)

    Khitruk, A. A.; Klimchenko, Yu. A.; Kovalchuk, O. A.; Marushin, E. L.; Mednikov, A. A.; Nasluzov, S. N.; Privalova, E. K.; Rodin, I. Yu.; Stepanov, D. B.; Sukhanova, M. V.

    2014-01-01

    One of the main tasks of superconductive magnets R and D is to determine the mechanical and fatigue properties of structural materials and the critical design elements in the cryogenic temperature range. This paper describes a new facility built based on the industrial 1000-ton (10 MN) testing machine Schenk PC10.0S. Special equipment was developed to provide the mechanical and cyclic tensile fatigue tests of large-scale samples at the liquid nitrogen temperature and in a given load range. The main feature of the developed testing machine is the cryostat, in which the device converting a standard compression force of the testing machine to the tensile force affected at the test object is placed. The control system provides the remote control of the test and obtaining, processing and presentation of test data. As an example of the testing machine operation the test program and test results of the cyclic tensile fatigue tests of fullscale helium inlet sample of the PF1 coil ITER are presented

  8. 17 CFR 229.1000 - (Item 1000) Definitions.

    Science.gov (United States)

    2010-04-01

    ... 17 Commodity and Securities Exchanges 2 2010-04-01 2010-04-01 false (Item 1000) Definitions. 229.1000 Section 229.1000 Commodity and Securities Exchanges SECURITIES AND EXCHANGE COMMISSION STANDARD INSTRUCTIONS FOR FILING FORMS UNDER SECURITIES ACT OF 1933, SECURITIES EXCHANGE ACT OF 1934 AND ENERGY POLICY AND CONSERVATION ACT OF 1975-REGULATION...

  9. Effect of inlet temperature on the performance of a catalytic reactor. [air pollution control

    Science.gov (United States)

    Anderson, D. N.

    1978-01-01

    A 12 cm diameter by 15 cm long catalytic reactor was tested with No. 2 diesel fuel in a combustion test rig at inlet temperatures of 700, 800, 900, and 1000 K. Other test conditions included pressures of 3 and 6 x 10 to the 5th power Pa, reference velocities of 10, 15, and 20 m/s, and adiabatic combustion temperatures in the range 1100 to 1400 K. The combustion efficiency was calculated from measurements of carbon monoxide and unburned hydrocarbon emissions. Nitrogen oxide emissions and reactor pressure drop were also measured. At a reference velocity of 10 m/s, the CO and unburned hydrocarbons emissions, and, therefore, the combustion efficiency, were independent of inlet temperature. At an inlet temperature of 1000 K, they were independent of reference velocity. Nitrogen oxides emissions resulted from conversion of the small amount (135 ppm) of fuel-bound nitrogen in the fuel. Up to 90 percent conversion was observed with no apparent effect of any of the test variables. For typical gas turbine operating conditions, all three pollutants were below levels which would permit the most stringent proposed automotive emissions standards to be met.

  10. K-band spectroscopic metallicities and temperatures of M-dwarf stars

    Directory of Open Access Journals (Sweden)

    Rojas-Ayala Bárbara

    2013-04-01

    Full Text Available I present the metallicity and effective temperature techniques developed for M dwarf stars by Rojas-Ayala et al. (2010, 2012. These techniques are based on absorption features present in the modest resolution K-band spectra (R∼2700 of M dwarfs and have been calibrated using FGK+M dwarf pairs and synthetic atmosphere models. The H2O-K2 index seems to overestimate the effective temperatures of M dwarfs when compared to interferometric measurements. The metallicity distribution of the M dwarf host candidates by the Kepler Mission hints that jovian-size planets form preferentially around solar and super-solar metallicity environments, while small rocky planet host exhibit a wide range of metallicities, just like in their solar-type counterparts.

  11. Electrical conductivity of molten CdCl{sub 2} at temperatures as high as 1474 K

    Energy Technology Data Exchange (ETDEWEB)

    Salyulev, Alexander B.; Potapov, Alexei M. [Russian Academy of Sciences, Ekaterinburg (Russian Federation). Inst. of High-Temperature Electrochemistry

    2016-11-01

    The electrical conductivity of molten CdCl{sub 2} was measured across a wide temperature range (ΔT=628 K), from 846 K to as high as 1474 K, i.e. 241 above the normal boiling point of the salt. In previous studies, a maximum temperature of 1201 K was reached, this being 273 lower than in the present work. The activation energy of electrical conductivity was calculated.

  12. Measurements of (p, ρ, T) properties for isobutane in the temperature range from 280 K to 440 K at pressures up to 200 MPa

    International Nuclear Information System (INIS)

    Miyamoto, H.; Uematsu, M.

    2006-01-01

    Measurements of (p, ρ, T) properties for isobutane in the compressed liquid phase have been obtained by means of a metal-bellows variable volumometer in the temperature range from 280 K to 440 K at pressures up to 200 MPa. The volume-fraction purity of isobutane used was 0.9999. The expanded uncertainties (k = 2) of temperature, pressure, and density measurements have been estimated to be less than 3 mK, 1.5 kPa (p ≤ 7 MPa), 0.06% (7 MPa 150 MPa), and 0.11%, respectively. In region more than 100 MPa at 280 K and 440 K, the uncertainty in density measurements rise up to 0.15% and 0.23%, respectively. The differences of the present density values at the same temperature between two series of measurements, in which the sample fillings are different, are within the maximum deviation of 0.09% in density, which is enough lower than the expanded uncertainty in density. Eight (p, ρ, T) measurements at the same temperatures and pressures as the literature values have been conducted for comparison. In addition, vapour pressures were measured at T = (280, 300) K. Moreover, the comparisons of the available equations of state with the present measurements are reported

  13. Acoustic resonator providing fixed points of temperature between 0.1 and 2 K

    International Nuclear Information System (INIS)

    Salmela, Anssi; Tuoriniemi, Juha; Pentti, Elias; Sebedash, Alexander; Rysti, Juho

    2009-01-01

    Below 2 K the speed of second sound in mixtures of liquid 3 He and 4 He first increases to a maximum of 30-40 m/s at about 1 K and then decreases again at lower temperatures to values below 15 m/s. The exact values depend on the concentration and pressure of the mixture. This can be exploited to provide fixed points in temperature by utilizing a resonator with appropriate dimensions and frequency to excite standing waves in the resonator cavity filled with helium mixture. We demonstrate that commercially mass produced quartz tuning forks can be used for this purpose. They are meant for frequency standards operating at 32 kHz. Their dimensions are typically of order 1 mm matching the wavelength of the second sound in helium mixtures at certain values of temperature. Due to the complicated geometry, we observe some 20 sharp acoustic resonances in the range 0.1l 2 K having temperature resolution of order 1 μK. The quartz resonators are cheap, compact, simple to implement, easy to measure with great accuracy, and, above all, they are not sensitive to magnetic field, which is a great advantage compared to fixed point devices based on superconductivity transitions. The reproducibility of the resonance pattern upon thermal cycling remains to be verified.

  14. High temperature superconducting current lead test facility with heat pipe intercepts

    International Nuclear Information System (INIS)

    Blumenfeld, P.E.; Prenger, C.; Roth, E.W.; Stewart, J.A.

    1998-01-01

    A high temperature superconducting (HTS) current lead test facility using heat pipe thermal intercepts is under development at the Superconducting Technology Center at Los Alamos National Laboratory. The facility can be configured for tests at currents up to 1,000 A. Mechanical cryocoolers provide refrigeration to the leads. Electrical isolation is maintained by intercepting thermal energy from the leads through cryogenic heat pipes. HST lead warm end temperature is variable from 65 K to over 90 K by controlling heat pipe evaporator temperature. Cold end temperature is variable up to 30 K. Performance predictions in terms of heat pipe evaporator temperature as a function of lead current are presented for the initial facility configuration, which supports testing up to 200 A. Measurements are to include temperature and voltage gradient in the conventional and HTS lead sections, temperature and heat transfer rate in the heat pipes. as well as optimum and off-optimum performance of the conventional lead sections

  15. The effect of temperature on pulsed positive streamer discharges in air over the range 292 K–1438 K

    Science.gov (United States)

    Ono, Ryo; Ishikawa, Yuta

    2018-05-01

    The effect of temperature on pulsed positive streamer discharges in air is measured by comparing atmospheric-pressure, high-temperature discharges with low-pressure, room-temperature discharges at the same air densities n and discharge voltages. Both discharges have the same reduced electric field E/n, so the differences between the two discharges only depend on the temperature, which is varied from 292 K to 1438 K. Temperature affects the discharge pulse energy most significantly; at 1438 K, the energy of an atmospheric-pressure discharge pulse is approximately 30 times larger than that of the corresponding 20.5 kPa, room-temperature discharge. Temperature also affects the shapes of the streamers when K, but no significant effect is observed for K. There is also no significant temperature effect on the spatially integrated intensity of N2(C–B) emission. However, temperature strongly affects the ratio of the integrated emission intensity to the discharge energy. No effect of the temperature is observed on the propagation velocity of the primary streamer or on the length of the secondary streamer.

  16. Electrical conductivity of molten ZnCl{sub 2} at temperature as high as 1421 K

    Energy Technology Data Exchange (ETDEWEB)

    Salyulev, Alexander B.; Potapov, Alexei M. [RAS Ural Branch, Ekaterinburg. (Russian Federation) Institute of High-Temperature Electrochemistry

    2015-07-01

    The electrical conductivity of molten ZnCl{sub 2} was measured in a wide temperature range (ΔT=863 K) to a temperature as high as 1421 K that is 417 degrees above the boiling point of the salt. At the temperature maximum of the own vapor pressure of the salt reached several megapascals.

  17. Effect of calcination temperature on the synthesis of potassium titanate with platy morphology

    International Nuclear Information System (INIS)

    Farina, R.; Fredericci, C.; Yoshimura, H.N.

    2011-01-01

    The dramatic increases in the number of pneumoconiosis cases have stimulated the search of new materials for replacement of asbestos fibers. Titanate plates with formula A y Ti 2-x M x O 4 , where A = K, Rb, Cs and M = Li, Mg, Co, Ni, Cu, Zn, Mn (III), Fe (III) have been studied as an alternative for the use of fibers. The effect of the variation of calcination temperature on the reaction of K 2 CO 3 -TiO 2 -Mg(OH) 2 system was studied with the aim of understanding the relationship of this parameter with the morphology and symmetry of the obtained plates. For this study the samples were calcined for 5 hours at temperatures of 950°C, 1000°C, 1050°C and 1100°C. The powders were analyzed by X-ray diffraction and scanning electron microscopy. It was concluded that 1000°C is the better calcination temperature for obtaining more symmetric plates with smaller particle size dispersion. (author)

  18. Carbon Nanostructure of Kraft Lignin Thermally Treated at 500 to 1000 °C.

    Science.gov (United States)

    Zhang, Xuefeng; Yan, Qiangu; Leng, Weiqi; Li, Jinghao; Zhang, Jilei; Cai, Zhiyong; Hassan, El Barbary

    2017-08-21

    Kraft lignin (KL) was thermally treated at 500 to 1000 °C in an inert atmosphere. Carbon nanostructure parameters of thermally treated KL in terms of amorphous carbon fraction, aromaticity, and carbon nanocrystallites lateral size ( L a ), thickness ( L c ), and interlayer space ( d 002 ) were analyzed quantitatively using X-ray diffraction, Raman spectroscopy, and high-resolution transmission electron microscopy. Experimental results indicated that increasing temperature reduced amorphous carbon but increased aromaticity in thermally treated KL materials. The L c value of thermally treated KL materials averaged 0.85 nm and did not change with temperature. The d 002 value decreased from 3.56 Å at 500 °C to 3.49 Å at 1000 °C. The L a value increased from 0.7 to 1.4 nm as temperature increased from 500 to 1000 °C. A nanostructure model was proposed to describe thermally treated KL under 1000 °C. The thermal stability of heat treated KL increased with temperature rising from 500 to 800 °C.

  19. Thermodynamic properties of molybdenum borides at temperatures above 300 K

    International Nuclear Information System (INIS)

    Bolgar, A.S.; Blinder, A.V.; Serbova, M.I.

    1990-01-01

    Enthalpy of Mo 2 B, MoB, Mo 2 B 5 borides within the range of temperatures above 300 K has been experimentally studied. Parameters of temperature dependences of enthalpy, heat capacity, entropy and the reduced Gibbs energy of the studied substances are calculated within a wide range. It is stated that high-temperature heat capacity of the studied borides can be presented as a sum of the electron component, a harmonic part of the lattice component and a contribution caused by anharmonic oscillations of lattice atoms. Values of coefficients of isothermal compressibility of Mo 2 , MoB, Mo 2 B 5 within the high temperature range are estimated

  20. RELAP5/SCDAPSIM model development for AP1000 and verification for large break LOCA

    Energy Technology Data Exchange (ETDEWEB)

    Trivedi, A.K. [Nuclear Engineering and Technology Program, Indian Institute of Technology, Kanpur 208016 (India); Allison, C. [Innovative Systems Software, Idaho Falls, ID 83406 (United States); Khanna, A., E-mail: akhanna@iitk.ac.in [Nuclear Engineering and Technology Program, Indian Institute of Technology, Kanpur 208016 (India); Munshi, P. [Nuclear Engineering and Technology Program, Indian Institute of Technology, Kanpur 208016 (India)

    2016-08-15

    Highlights: • RELAP5/SCDAPSIM model of AP1000 has been developed. • Analysis involves a LBLOCA (double ended guillotine break) study in cold leg. • Results are compared with those of WCOBRA–TRAC and TRACE. • Concluded that PCT does not violate the safety criteria of 1477 K. - Abstract: The AP1000 is a Westinghouse 2-loop pressurized water reactor (PWR) with all emergency core cooling systems based on natural circulation. Its core design is very similar to a 3-loop PWR with 157 fuel assemblies. Westinghouse has reported their results of the safety analysis in its design control document (DCD) for a large break loss of coolant accident (LOCA) using WCOBRA/TRAC and for a small break LOCA using NOTRUMP. The current study involves the development of a representative RELAP5/SCDASIM model for AP1000 based on publically available data and its verification for a double ended cold leg (DECL) break in one of the cold legs in the loop containing core makeup tanks (CMT). The calculated RELAP5/SCDAPSIM results have been compared to publically available WCOBRA–TRAC and TRACE results of DECL break in AP1000. The objective of this study is to benchmark thermal hydraulic model for later severe accident analyses using the 2D SCDAP fuel rod component in place of the RELAP5 heat structures which currently represent the fuel rods. Results from this comparison provides sufficient confidence in the model which will be used for further studies such as a station blackout. The primary circuit pumps, pressurizer and steam generators (including the necessary secondary side) are modeled using RELAP5 components following all the necessary recommendations for nodalization. The core has been divided into 6 radial rings and 10 axial nodes. For the RELAP5 thermal hydraulic calculation, the six groups of fuel assemblies have been modeled as pipe components with equivalent flow areas. The fuel including the gap and cladding is modeled as a 1d heat structure. The final input deck achieved

  1. Thermodynamic constants of N-[tris(hydroxymethyl)methyl-3-amino]propanesulfonic acid (Taps) from the temperatures 278.15 K to 328.15 K

    International Nuclear Information System (INIS)

    Roy, Rabindra N.; Roy, Lakshmi N.; LeNoue, Sean R.; Denton, Cole E.; Simon, Ashley N.; Richards, Sarah J.; Moore, Andrew C.; Roy, Chandra N.; Redmond, R. Ryan; Bryant, Paul A.

    2006-01-01

    Values of the second thermodynamic dissociation constant pK 2 of N-[tris(hydroxymethyl)methyl-3-amino]propanesulfonic acid (Taps) have been determined at twelve temperatures from 278.15 K to 328.15 K including 310.15 K by measurements of the electromotive-force for cells without liquid junction of the type: Pt|H 2 (g, p - bar =101.325 kPa)|Taps (m 1 ), NaTapsate (m 2 ), NaCl (m 3 )|AgCl|Ag, where m denotes molality. The pK 2 values for the dissociation of Taps are represented by the equation: pK 2 =2969.61.(K/T) - 17.05052+2.73697.ln(T/K). The values of pK 2 for Taps were found to be (8.502+/-0.0007) at T=298.15 K and (8.225+/-0.0009) at T=310.15 K, respectively, indicating thereby to be useful as buffer solutions for pH control in the region 7.4 to 8.5. The thermodynamic quantities, ΔG - bar , ΔH - bar , ΔS - bar , and ΔC p - bar dissociation process of Taps have been derived from the temperature coefficients of the pK 2

  2. A low-temperature (4-300K) constant volume gas thermometer

    International Nuclear Information System (INIS)

    Combarieu, A. de

    1976-01-01

    A constant volume gas thermometer was built to calibrate the various secondary thermometers used at low temperature. This gas thermometer is placed in a cryostat where any stable temperature between 4 and 300K may be obtained. The principle is outlined, then the gas thermometer and its auxiliary equipment are briefly described; the corrections to be applied to the results are given and a table shows the values obtained [fr

  3. The drift velocity of electrons in carbon dioxide at temperatures between 193 and 573 K

    International Nuclear Information System (INIS)

    Elford, M.T.; Haddad, G.N.

    1980-01-01

    The drift velocity of electrons in carbon dioxide has been measured at gas temperatures ranging from 193 to 573 K and at E/N values up to 20 Td at 193 K, 50 Td at 293 K and 40 Td at 573 K. The measured drift velocities were found to decrease linearly with increasing gas number density at a given value of E/N for gas temperatures less than 293 K. This dependence has been attributed to multiple scattering and the data have been extrapolated to zero number density to correct for this effect. Comparisons are made with previous measurements where available. The present data for the variation of μN(thermal) with temperature agree to within the experimental error with the data of Pact et al. (1962)

  4. Analysis of WWER 1000 SG cold collector cracking

    International Nuclear Information System (INIS)

    Matocha, K.; Wozniak, J.

    2000-01-01

    Following the recommendations of the 1993 consultants' meeting on 'Steam Generator Collector Integrity of WWER 1000 Reactors', an extensive experimental program was started with the aim of finding the dominant damage mechanism responsible for cold collector cracking in steam generators, and of determining whether proper operating conditions can make the operation of VITKOVICE-produced steam generators safe throughout their lifetime. The experiments consisted of: a study of the effect of strain and thermal ageing and dissolved oxygen content on subcritical crack growth in 10GN2MFA steel; a study of the effect of high temperature water and tube expansion technology on the fracture behaviour of ligaments between holes for heat exchange tubes; a study of the effect of drilling, tube expansion technology and heat treatment on residual stresses on the surface of holes for heat exchange tubes. Details of the experimental techniques used are given as well as a discussion of the results obtained and presented in tables and graphs. (A.K.)

  5. Optimal thermionic energy conversion with established electrodes for high-temperature topping and process heating. [coal combustion product environments

    Science.gov (United States)

    Morris, J. F.

    1980-01-01

    Applied research-and-technology (ART) work reveals that optimal thermionic energy conversion (TEC) with approximately 1000 K to approximately 1100 K collectors is possible using well established tungsten electrodes. Such TEC with 1800 K emitters could approach 26.6% efficiency at 27.4 W/sq cm with approximately 1000 K collectors and 21.7% at 22.6 W/sq cm with approximately 1100 K collectors. These performances require 1.5 and 1.7 eV collector work functions (not the 1 eV ultimate) with nearly negligible interelectrode losses. Such collectors correspond to tungsten electrode systems in approximately 0.9 to approximately 6 torr cesium pressures with 1600 K to 1900 K emitters. Because higher heat-rejection temperatures for TEC allow greater collector work functions, interelectrode loss reduction becomes an increasingly important target for applications aimed at elevated temperatures. Studies of intragap modifications and new electrodes that will allow better electron emission and collection with lower cesium pressures are among the TEC-ART approaches to reduced interelectrode losses. These solutions will provide very effective TEC to serve directly in coal-combustion products for high-temperature topping and process heating. In turn this will help to use coal and to use it well.

  6. Influence of ultra-thin TiN thickness (1.4 nm and 2.4 nm) on positive bias temperature instability (PBTI) of high-k/metal gate nMOSFETs with gate-last process

    International Nuclear Information System (INIS)

    Qi Lu-Wei; Yang Hong; Ren Shang-Qing; Xu Ye-Feng; Luo Wei-Chun; Xu Hao; Wang Yan-Rong; Tang Bo; Wang Wen-Wu; Yan Jiang; Zhu Hui-Long; Zhao Chao; Chen Da-Peng; Ye Tian-Chun

    2015-01-01

    The positive bias temperature instability (PBTI) degradations of high-k/metal gate (HK/MG) nMOSFETs with thin TiN capping layers (1.4 nm and 2.4 nm) are systemically investigated. In this paper, the trap energy distribution in gate stack during PBTI stress is extracted by using ramped recovery stress, and the temperature dependences of PBTI (90 °C, 125 °C, 160 °C) are studied and activation energy (E a ) values (0.13 eV and 0.15 eV) are extracted. Although the equivalent oxide thickness (EOT) values of two TiN thickness values are almost similar (0.85 nm and 0.87 nm), the 2.4-nm TiN one (thicker TiN capping layer) shows better PBTI reliability (13.41% at 0.9 V, 90 °C, 1000 s). This is due to the better interfacial layer/high-k (IL/HK) interface, and HK bulk states exhibited through extracting activation energy and trap energy distribution in the high-k layer. (paper)

  7. Reprint of “Heat capacity and transition behavior of sucrose by standard, fast scanning and temperature-modulated calorimetry”

    Energy Technology Data Exchange (ETDEWEB)

    Magoń, A. [Department of Chemistry, University of Technology, 35-959 Rzeszów (Poland); Wurm, A.; Schick, C. [Department of Physics, University of Rostock, 18057 Rostock (Germany); Pangloli, Ph.; Zivanovic, S. [Department of Food Science and Technology, University of Tennessee, Knoxville, TN 37996 (United States); Skotnicki, M. [Department of Pharmaceutical Technology, Poznan University of Medical Sciences, 60-780 Poznań (Poland); Pyda, M., E-mail: mpyda@utk.edu [Department of Chemistry, University of Technology, 35-959 Rzeszów (Poland)

    2015-03-10

    Highlights: • Experimental, apparent heat capacity of sucrose was investigated by advanced thermal analysis. • Vibrational heat capacity of solid state was linked with a low temperature experimental heat capacity of sucrose. • Equilibrium melting parameters of sucrose were determined. • Decomposition, superheating of crystalline sucrose during melting process were presented. • TGA, DSC, TMDSC, and FSC are useful tools for characterization of sucrose. - Abstract: The heat capacity (C{sub p}) of crystalline and amorphous sucrose was determined using standard and quasi-isothermal temperature modulated differential scanning calorimetry. The results were combined with the published data determined by adiabatic calorimetry, and the C{sub p} values are now reported for the wide 5–600 K range. The experimental C{sub p} of solid sucrose at 5–300 K was used to calculate the vibrational, solid C{sub p} based on the vibrational molecular motions. The calculated solid and liquid C{sub p} together with the transition parameters for equilibrium conditions were used as references for detailed quantitative thermal analysis of crystalline and amorphous sucrose. Melting temperature (T{sub m}) of the crystalline sucrose was identified in a broad 442–465 K range with a heat of fusion of 40–46 J/mol determined at heating rates 0.5–20 K/min, respectively. The equilibrium T{sub m} and heat of fusion of crystalline sucrose were estimated at zero heating rate as T{sup o}{sub m} = 424.4 K and ΔH{sup o}{sub f} = 32 kJ/mol, respectively. The glass transition temperature (T{sub g}) of amorphous sucrose was at 331 K with a change in C{sub p} of 267 J/(mol K) as it was estimated from reversing heat capacity by quasi-isothermal TMDSC on cooling. At heating rates less than 30 K/min, thermal decomposition occurred during melting, while at extreme rate of 1000 K/s, degradation was not observed. Data obtained by fast scanning calorimetry (FSC) at 1000 K/s, showed that T{sub m} was

  8. Wide temperature range (T = 295 K and 770-1305 K) study of the kinetics of the reactions HCO + NO and HCO + NO2 using frequency modulation spectroscopy.

    Science.gov (United States)

    Dammeier, J; Colberg, M; Friedrichs, G

    2007-08-21

    The rate constants for , HCO + NO --> HNO + CO, and , HCO + NO(2)--> products, have been measured at temperatures between 770 K modulation (FM) absorption spectroscopy. Kinetic simulations based on a comprehensive reaction mechanism showed that the rate constants for the title reactions could be sensitively extracted from the measured HCO profiles. The determined high temperature rate constants are k(1)(769-1307 K) = (7.1 +/- 2.7) x 10(12) cm(3) mol(-1) s(-1) and k(2)(804-1186 K) = (3.3 +/- 1.8) x 10(13) cm(3) mol(-1) s(-1). The room temperature values were found to be in very good agreement with existing literature data and show that both reactions are essentially temperature independent. The weak temperature dependence of can be explained by the interplay of a dominating direct abstraction pathway and a complex-forming mechanism. Both pathways yield the products HNO + CO. In contrast to , no evidence for a significant contribution of a direct high temperature abstraction channel was found for . Here, the observed temperature independent overall rate constant can be described by a complex-forming mechanism with several product channels. Detailed information on the strongly temperature dependent channel branching ratios is provided. Moreover, the high temperature rate constant of , OH + (CHO)(2), has been determined to be k(7) approximately 1.1 x 10(13) cm(3) mol(-1) s(-1).

  9. Time of day influences the voluntary intake and behavioral response to methamphetamine and food reward.

    Science.gov (United States)

    Keith, Diana R; Hart, Carl L; Robotham, Margaret; Tariq, Maliha; Le Sauter, Joseph; Silver, Rae

    2013-09-01

    The circadian timing system influences a vast array of behavioral responses. Substantial evidence indicates a role for the circadian system in regulating reward processing. Here we explore time of day effects on drug anticipation, locomotor activity, and voluntary methamphetamine (MA) and food intake in animals with ad libitum food access. We compared responses to drug versus a palatable treat during their normal sleep times in early day (zeitgeber time (ZT) 0400) or late day (ZT 1000). In the first study, using a between-subjects design, mice were given daily 1-h access to either peanut butter (PB-Alone) or to a low or high concentration of MA mixed in PB (MA+PB). In study 2, we repeated the experiment using a within-subjects design in which mice could choose between PB-Alone and MA+PB at either ZT 0400 or 1000. In study 3, the effects of MA-alone were investigated by evaluating anticipatory activity preceding exposure to nebulized MA at ZT 0400 vs. ZT 1000. Time of day effects were observed for both drug and palatable treat, such that in the between groups design, animals showed greater intake, anticipatory activity, and post-ingestional activity in the early day. Furthermore, there were differences among mice in the amount of MA ingested but individuals were self-consistent in their daily intake. The results for the within-subjects experiment also revealed robust individual differences in preference for MA+PB or PB-Alone. Interestingly, time of day effects on intake were observed only for the preferred substance. Anticipatory activity preceding administration of MA by nebulization was also greater at ZT 0400 than ZT 1000. Finally, pharmacokinetic response to MA administered intraperitoneally did not vary as a function of time of administration. The results indicate that time of day is an important variable mediating the voluntary intake and behavioral effects of reinforcers. Copyright © 2013 Elsevier Inc. All rights reserved.

  10. Experimental and numerical study of the high-temperature structure of copper single crystal surfaces

    International Nuclear Information System (INIS)

    Loisel, Bertrand

    1989-01-01

    The structure of copper single crystal surfaces has been investigated on an atomic scale using two complementary tools: helium beam diffraction experiments and computer simulations by molecular dynamics. In the case of stepped surfaces, the roughening transition occurs at low temperature. Our helium beam diffraction experiments in the range 70-1000 K reveal this transition at 650±50 K and 150±50 K respectively on the (331) and (310) surfaces. We emphasize the role of the terrace and step structure on the thermal roughness, which is ruled by microscopic energies related to the creation and interaction of defects on the step edges. Adsorbing oxygen on a rough (310) surface gives rise to ordered superstructures. In our computer simulations, the interatomic forces are derived from an empiric N-body potential which leads to a realistic description of the static and dynamical properties of the bulk metal and its surfaces. We analyze the results of high-temperature simulations on the (110) surface. Two types of disorder are distinguished: the creation of adatom-vacancy pairs and the enhancement of the vibrational amplitudes of the atoms near their equilibrium site. We establish that both phenomena take place in the same temperature range. These simulations also indicate the very anisotropic behaviour of the surface at high temperatures (> 1000 K). (author) [fr

  11. The Single Transmembrane Segment of Minimal Sensor DesK Senses Temperature via a Membrane-Thickness Caliper.

    Science.gov (United States)

    Inda, Maria E; Oliveira, Rafael G; de Mendoza, Diego; Cybulski, Larisa E

    2016-11-01

    Thermosensors detect temperature changes and trigger cellular responses crucial for survival at different temperatures. The thermosensor DesK is a transmembrane (TM) histidine kinase which detects a decrease in temperature through its TM segments (TMS). Here, we address a key issue: how a physical stimulus such as temperature can be converted into a cellular response. We show that the thickness of Bacillus lipid membranes varies with temperature and that such variations can be detected by DesK with great precision. On the basis of genetic studies and measurements of in vitro activity of a DesK construct with a single TMS (minimal sensor DesK [MS-DesK]), reconstituted in liposomes, we propose an interplay mechanism directed by a conserved dyad, phenylalanine 8-lysine 10. This dyad is critical to anchor the only transmembrane segment of the MS-DesK construct to the extracellular water-lipid interphase and is required for the transmembrane segment of MS-DesK to function as a caliper for precise measurement of membrane thickness. The data suggest that positively charged lysine 10, which is located in the hydrophobic core of the membrane but is close to the water-lipid interface, pulls the transmembrane region toward the water phase to localize its charge at the interface. Nevertheless, the hydrophobic residue phenylalanine 8, located at the N-terminal extreme of the TMS, has a strong tendency to remain in the lipid phase, impairing access of lysine 10 to the water phase. The outcome of this interplay is a fine-tuned sensitivity to membrane thickness that elicits conformational changes that favor different signaling states of the protein. The ability to sense and respond to extracellular signals is essential for cell survival. One example is the cellular response to temperature variation. How do cells "sense" temperature changes? It has been proposed that the bacterial thermosensor DesK acts as a molecular caliper measuring membrane thickness variations that would occur

  12. Internal variability in a 1000-yr control simulation with the coupled climate model ECHO-G - I. Near-surface temperature, precipitation and mean sea level pressure.

    Energy Technology Data Exchange (ETDEWEB)

    Min, Seung-Ki; Hense, Andreas [Univ. of Bonn (Germany). Meteorological Inst.; Legutke, Stephanie [Max Planck Inst. for Meteorology, Hamburg (Germany); Kwon, Won-Tae [Meteorological Research Inst., Seoul (Korea, Republic of)

    2005-08-01

    The internal variability in a 1000-yr control simulation with the coupled atmosphere/ocean global climate model ECHO-G is analysed using near-surface temperature, precipitation and mean sea level pressure variables, and is compared with observations and other coupled climate model simulations. ECHO-G requires annual mean flux adjustments for heat and freshwater in order to simulate no significant climate drift for 1000 yr, but no flux adjustments for momentum. The ECHO-G control run captures well most aspects of the observed seasonal and annual climatology and of the interannual to decadal variability of the three variables. Model biases are very close to those in ECHAM4 (atmospheric component of ECHO-G) stand-alone integrations with prescribed observed sea surface temperature. A trend comparison between observed and modelled near-surface temperatures shows that the observed near-surface global warming is larger than internal variability produced by ECHO-G, supporting previous studies. The simulated global mean near-surface temperatures, however, show a 2-yr spectral peak which is linked with a strong biennial bias of energy in the El Nino Southern Oscillation signal. Consequently, the interannual variability (39 yr) is underestimated.

  13. Sample environment for neutron scattering measurements of internal stresses in engineering materials in the temperature range of 6 K to 300 K.

    Science.gov (United States)

    Kirichek, O; Timms, J D; Kelleher, J F; Down, R B E; Offer, C D; Kabra, S; Zhang, S Y

    2017-02-01

    Internal stresses in materials have a considerable effect on material properties including strength, fracture toughness, and fatigue resistance. The ENGIN-X beamline is an engineering science facility at ISIS optimized for the measurement of strain and stress using the atomic lattice planes as a strain gauge. Nowadays, the rapidly rising interest in the mechanical properties of engineering materials at low temperatures has been stimulated by the dynamic development of the cryogenic industry and the advanced applications of the superconductor technology. Here we present the design and discuss the test results of a new cryogenic sample environment system for neutron scattering measurements of internal stresses in engineering materials under a load of up to 100 kN and in the temperature range of 6 K to 300 K. Complete cooling of the system starting from the room temperature down to the base temperature takes around 90 min. Understanding of internal stresses in engineering materials at cryogenic temperatures is vital for the modelling and designing of cutting-edge superconducting magnets and other superconductor based applications.

  14. Continental-Scale Temperature Reconstructions from the PAGES 2k Network

    Science.gov (United States)

    Kaufman, D. S.

    2012-12-01

    We present a major new synthesis of seven regional temperature reconstructions to elucidate the global pattern of variations and their association with climate-forcing mechanisms over the past two millennia. To coordinate the integration of new and existing data of all proxy types, the Past Global Changes (PAGES) project developed the 2k Network. It comprises nine working groups representing eight continental-scale regions and the oceans. The PAGES 2k Consortium, authoring this paper, presently includes 79 representatives from 25 countries. For this synthesis, each of the PAGES 2k working groups identified the proxy climate records for reconstructing past temperature and associated uncertainty using the data and methodologies that they deemed most appropriate for their region. The datasets are from 973 sites where tree rings, pollen, corals, lake and marine sediment, glacier ice, speleothems, and historical documents record changes in biologically and physically mediated processes that are sensitive to temperature change, among other climatic factors. The proxy records used for this synthesis are available through the NOAA World Data Center for Paleoclimatology. On long time scales, the temperature reconstructions display similarities among regions, and a large part of this common behavior can be explained by known climate forcings. Reconstructed temperatures in all regions show an overall long-term cooling trend until around 1900 C.E., followed by strong warming during the 20th century. On the multi-decadal time scale, we assessed the variability among the temperature reconstructions using principal component (PC) analysis of the standardized decadal mean temperatures over the period of overlap among the reconstructions (1200 to 1980 C.E.). PC1 explains 35% of the total variability and is strongly correlated with temperature reconstructions from the four Northern Hemisphere regions, and with the sum of external forcings including solar, volcanic, and greenhouse

  15. Effect of degree of polymerization and of temperature on the reactivity of poly(vinyl alcohol) by applying T-for-H exchange reaction

    International Nuclear Information System (INIS)

    Imaizumi, Hiroshi; Imai, Kazunari

    1999-01-01

    In order to reveal the effect of the degree of polymerization and of temperature on the reactivity of functional polymers, the hydrogen-isotope exchange reaction between poly(vinyl alcohol) (PVA) having each degree of polymerization and tritiated water vapor (HTO vapor) was dynamically observed at 35-80 deg C in a gas-solid system. The reason of the observation at 35 deg C is to clarify the possibility of the T-for-H exchange reaction at a temperature near the environment. The degree of polymerization of PVA used in this work was 500, 1000, 2000, 2800, or 3500. Applying the A''-McKay plot method to the data obtained in each observation, the rate constant (k) for each PVA in the reaction was calculated. Moreover, the Arrhenius plot for each PVA was made by using the k values. Comparing the k values and the results obtained previously, the following six matters have been clarified. In the temperature range of 35-80 deg C, the T-for-H exchange reaction between HTO vapor and each PVA occurred, and in this case, the atoms participating in the reaction are the H atoms in the OH groups in PVA and T atoms in HTO vapor. The reactivity of each PVA increases with rising temperature, and decreases with increasing the degree of polymerization. The rate of the decreasing of k with increasing the degree of polymerization changes at near the degree of polymerization of 1000, and the rate is fairly large under the degree of 1000. Under the degree of polymerization of 1000, the reactivity of PVA is more affected by the effect of the degree of polymerization than by the effect of temperature, and the reactivity is large when the degree of polymerization is small. Over the degree of polymerization of 1000, the reactivity of PVA is affected by both the degree of polymerization and temperature, and the reactivity is large when temperature is high. For the T-for-H exchange reaction in a gas-solid system, the reaction form is unchanged in the range of 35-80 deg C, and the reactivity at 35

  16. Thermodynamic constants of N-[tris(hydroxymethyl)methyl-3-amino]propanesulfonic acid (Taps) from the temperatures 278.15 K to 328.15 K

    Energy Technology Data Exchange (ETDEWEB)

    Roy, Rabindra N. [Walter H. Hoffman Department of Chemistry, Drury University, 900 N. Benton Avenue, Springfield, MO 65802 (United States)]. E-mail: rroy@drury.edu; Roy, Lakshmi N. [Walter H. Hoffman Department of Chemistry, Drury University, 900 N. Benton Avenue, Springfield, MO 65802 (United States); LeNoue, Sean R. [Walter H. Hoffman Department of Chemistry, Drury University, 900 N. Benton Avenue, Springfield, MO 65802 (United States); Denton, Cole E. [Walter H. Hoffman Department of Chemistry, Drury University, 900 N. Benton Avenue, Springfield, MO 65802 (United States); Simon, Ashley N. [Walter H. Hoffman Department of Chemistry, Drury University, 900 N. Benton Avenue, Springfield, MO 65802 (United States); Richards, Sarah J. [Walter H. Hoffman Department of Chemistry, Drury University, 900 N. Benton Avenue, Springfield, MO 65802 (United States); Moore, Andrew C. [Walter H. Hoffman Department of Chemistry, Drury University, 900 N. Benton Avenue, Springfield, MO 65802 (United States); Roy, Chandra N. [Walter H. Hoffman Department of Chemistry, Drury University, 900 N. Benton Avenue, Springfield, MO 65802 (United States); Redmond, R. Ryan [Walter H. Hoffman Department of Chemistry, Drury University, 900 N. Benton Avenue, Springfield, MO 65802 (United States); Bryant, Paul A. [Walter H. Hoffman Department of Chemistry, Drury University, 900 N. Benton Avenue, Springfield, MO 65802 (United States)

    2006-04-15

    Values of the second thermodynamic dissociation constant pK{sub 2} of N-[tris(hydroxymethyl)methyl-3-amino]propanesulfonic acid (Taps) have been determined at twelve temperatures from 278.15 K to 328.15 K including 310.15 K by measurements of the electromotive-force for cells without liquid junction of the type: Pt|H{sub 2} (g, p{sup -}bar =101.325 kPa)|Taps (m{sub 1}), NaTapsate (m{sub 2}), NaCl (m{sub 3})|AgCl|Ag, where m denotes molality. The pK{sub 2} values for the dissociation of Taps are represented by the equation: pK{sub 2}=2969.61.(K/T) - 17.05052+2.73697.ln(T/K). The values of pK{sub 2} for Taps were found to be (8.502+/-0.0007) at T=298.15 K and (8.225+/-0.0009) at T=310.15 K, respectively, indicating thereby to be useful as buffer solutions for pH control in the region 7.4 to 8.5. The thermodynamic quantities, {delta}G{sup -}bar , {delta}H{sup -}bar , {delta}S{sup -}bar , and {delta}C{sub p}{sup -}bar dissociation process of Taps have been derived from the temperature coefficients of the pK{sub 2}.

  17. Experimental (155 K) and predicted (151 K) Curie temperature (Tc) of K2ZnBr4: structural confirmation of ferroelectric state below Tc

    International Nuclear Information System (INIS)

    Abrahams, S.C.

    1994-01-01

    The temperature T c at which K 2 ZnBr 4 is predicted to transform from the paraelectric to the ferroelectric phase is 151 (19) K, based on the crystal structure determinations at 291 and 144 K by Fabry, Breczewski, Zuniga and Arnaiz and the Abrahams-Kurtz-Jamieson relationship. A dielectric and heat-capacity anomaly in this material at 155 K has been reported elsewhere. The locations reported for the ZnBr 2- 4 and K + ions fulfill the requirements of mirror plane symmetry above T c ; ionic displacements along the polar direction that approach but do not exceed 0.1 A and that violate the mirror symmetry on cooling through T c form the basis of the prediction and satisfy the structural criteria for ferroelectricity in the phase below the transition. (orig.)

  18. High Temperature Catalytic Combustion Suppports Final Report CRADA No. TSB-0841-94

    Energy Technology Data Exchange (ETDEWEB)

    Hair, Lucy [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Magno, Scott [Catalytic Combustion Systems, Inc., Mountain View, CA (United States)

    2018-01-19

    This Small Business CRADA between LLNL and Catalytica was executed on January 25, 1995. The total estimated cost of this project was 113K. LLNL's contribution was estimated at $50K funded under the DOE/Defense Program Small Business Initiative. Catalytica's in-kind contribution was estimated at 63K. Catalytic combusion catalyst systems operate at temperatures from 600°C to above 1300°C. Catalytica has developed technology that limits the catalyst temperature to below 1000°C. At temperatures in the range of 850 to 1000°C, the thermal stability of the catalyst is an important issue. Typical supports such as stabilized aluminas, hexaluminates, zirconia and stabilized zirconia supports are typically used but lack either thermal stability or other desirable properties. Catalytica had developed a new concept for thermally stable mixed oxide supports but this concept required the preparation of molecularly uniform precursors; that is, prior to high temperature treatment of these materials, the elements that make up the mixed oxide must be as nearly uniform as possible on a molecular level. The technique of sol gel processing appeared to be the preferred technique to make these molecularly uniform precursors, and a cooperative program with LLNL was established to prepare and test the proposed compounds. Catalytica proposed the composition and concentration levels for the materials to be prepared.

  19. Mechanical behaviour of substitutional body centered cubic Fe-Ti solid solutions at temperatures between 77 and 900 K; Plasticite des solutions solides cubiques centrees substitutionnelles fer-titane aux temperatures comprises entre 77 et 900 K

    Energy Technology Data Exchange (ETDEWEB)

    Dubots, Patrick

    1976-05-11

    Plastic behavior of body-centered cubic, interstitial free, Fe-Ti substitutional solid solutions has been characterised. We obtained the following results: at temperatures below 500 K, the thermal component τ* of the critical resolved shear stress τ greatly increases. Solute additions (c >0.12 wt pc) results in: softening at temperatures below 200 K, hardening at temperatures between 200 and 500 K. Results are discussed on Peierls mechanism. At temperatures below 200 K, screw dislocation motion is controlled.by the nucleation of dislocation pairs over the Peierls'hill. Substitutional solute favoring this process gives account of the softening. At temperatures above 200 K, edge dislocation motion controls the strain. The observed hardening is explained by the interaction occurring between edge-dislocations and foreign atoms. At temperatures between 500 and 800 K, a Portevin-Le Chatelier effect is observed. This effect is characterised by two types of serrations. The activation energy of the PLC effect has been determined (E = 1,4 eV). The origin of this phenomenon is the diffusion of solute towards dislocation by a vacancy-mechanism. Two maxima have been observed on the (σ{sub ε} - T) curves. These are due to superposition of overstraining (hardening) and creation of dislocations (softening). The athermal component τ{sub μ} is increased by titanium additions. This hardening has been explained by modulus and size effects. (author) [French] La caracterisation des mecanismes controlant la deformation plastique des solutions solides cubiques centrees substitutionnelles fer-titane, libres d'interstitiels pour les teneurs en solute superieures a 0,12pc pds, a donne les resultats suivants: aux temperatures inferieures a 500 K, la composante thermique τ* de la contrainte critique de cisaillement resolue τ augmente fortement. L'introduction du solute se traduit (pour c>0,12 pc pds): par un adoucissement pour θ < 200 K; par un durcissement pour 200 K< θ < 500 K. Le

  20. Low-temperature magnetic ordering in the perovskites Pr1-xAxCoO3 (A=Ca, Sr)

    International Nuclear Information System (INIS)

    Deac, Iosif G.; Tetean, Romulus; Balasz, Istvan; Burzo, Emil

    2010-01-01

    The magnetic and electrical properties of polycrystalline Pr 1-x A x CoO 3 cobaltites with A=Ca, Sr and 0≤x≤0.5 were studied in the temperature range 4 K≤T≤1000 K and field up to 7 T. The X-ray analyses show the presence of only one phase having monoclinic or orthorhombic symmetry. The magnetic measurements indicate that the Ca-doped samples have at low temperatures, similar properties to the frustrated magnetic materials. PrCoO 3 is a paramagnetic insulator in the range from 4 to 1000 K. The Sr-doped cobaltites exhibit two phase transitions: a paramagnetic-ferromagnetic (or magnetic phase separated state) phase transition at about 240 K and a second one at about 100 K. The magnetic measurements suggest the presence of magnetic clusters and a change in the nature of magnetic coupling between Co ions at low temperatures. A semiconducting type behavior and high negative magnetoresistance was found for the Ca-doped samples, while the Sr-doped ones were metallic and with negligible magnetoresistance. The results are analyzed in the frame of a phase separation scenario in the presence of the spin-state transitions of Co ions.

  1. The Successful Operation of Hole-type Gaseous Detectors at Cryogenic Temperatures

    CERN Document Server

    Pereiale, L.; Iacobaeus, C.; Francke, T.; Lund-Jensen, B.; Pavlopoulos, P.; Picchi, P.; Pietropaolo, F.; Tokanai, F.

    2004-01-01

    We have demonstrated that hole-type gaseous detectors, GEMs and capillary plates, can operate up to 77 K. For example, a single capillary plate can operate at gains of above 10E3 in the entire temperature interval between 300 until 77 K. The same capillary plate combined with CsI photocathodes could operate perfectly well at gains (depending on gas mixtures) of 100-1000. Obtained results may open new fields of applications for capillary plates as detectors of UV light and charge particles at cryogenic temperatures: noble liquid TPCs, WIMP detectors or LXe scintillating calorimeters and cryogenic PETs.

  2. Bilateral Comparison Between NIM and NMC Over the Temperature Range from 83.8058 K to 692.677 K

    Science.gov (United States)

    Sun, Jianping; Ye, Shaochun; Kho, Haoyuan; Zhang, Jintao; Wang, Li

    2015-08-01

    A bilateral comparison of local realization of the International Temperature Scale of 1990 between the National Institute of Metrology (NIM) and National Metrology Centre (NMC) was carried out over the temperature range from 83.8058 K to 692.677 K. It involved six fixed points including the argon triple point, the mercury triple point, the triple point of water, the melting point of gallium, the freezing point of tin, and the freezing point of zinc. In 2009, NMC asked NIM to participate in a bilateral comparison to link the NMC results to the Consultative Committee for Thermometry Key Comparison 3 (CCT-K3) and facilitate the NMC's calibration and measurement capabilities submission. This comparison was agreed by NIM and Asia Pacific Metrology Programme in 2009, and registered in the Key Comparison Database in 2010 as CCT-K3.2. NMC supplied two fused silica sheath standard platinum resistance thermometers (SPRTs) as traveling standards. One of them was used at the Ga, Sn, and Zn fixed points, while the other one was used at the Ar and Hg fixed points. NMC measured them before and after NIM measured them. During the comparison, a criterion for the SPRT was set as the stability at the triple point of water to be less than 0.3 mK. The results for both laboratories are summarized. A proposal for linking the NMC's comparison results to CCT-K3 is presented. The difference between NMC and NIM and the difference between NMC and the CCT-K3 average reference value using NIM as a link are reported with expanded uncertainties at each measured fixed point.

  3. Low-temperature magnetic ordering in the perovskites Pr 1-xA xCoO 3 (A=Ca, Sr)

    Science.gov (United States)

    Deac, Iosif G.; Tetean, Romulus; Balasz, Istvan; Burzo, Emil

    2010-05-01

    The magnetic and electrical properties of polycrystalline Pr 1-xA xCoO 3 cobaltites with A=Ca, Sr and 0≤ x≤0.5 were studied in the temperature range 4 K≤ T≤1000 K and field up to 7 T. The X-ray analyses show the presence of only one phase having monoclinic or orthorhombic symmetry. The magnetic measurements indicate that the Ca-doped samples have at low temperatures, similar properties to the frustrated magnetic materials. PrCoO 3 is a paramagnetic insulator in the range from 4 to 1000 K. The Sr-doped cobaltites exhibit two phase transitions: a paramagnetic-ferromagnetic (or magnetic phase separated state) phase transition at about 240 K and a second one at about 100 K. The magnetic measurements suggest the presence of magnetic clusters and a change in the nature of magnetic coupling between Co ions at low temperatures. A semiconducting type behavior and high negative magnetoresistance was found for the Ca-doped samples, while the Sr-doped ones were metallic and with negligible magnetoresistance. The results are analyzed in the frame of a phase separation scenario in the presence of the spin-state transitions of Co ions.

  4. Effective temperatures of late-type stars: The field giants from K0 to M6

    International Nuclear Information System (INIS)

    Ridgway, S.T.; Joyce, R.R.; White, N.M.; Wing, R.F.

    1980-01-01

    Angular diameters from lunar occultation are combined with infrared photometry to determine effective temperatures, T/sub eff/, for K0--M6 giants. The relation between T/sub eff/ and color temperature, MK spectral type, V--K color, and I (104) --L color are derived. The principal result is a general increase in T/sub eff/ for the cooler spectral types compared to previous calibrations. Throughout the temperature range studied, we obtain excellent agreement with recent model atmosphere computations

  5. Thermal properties of Permian Basin evaporites to 493 K temperature and 30 MPa confining pressure

    International Nuclear Information System (INIS)

    Durham, W.B.; Heard, H.C.; Boro, C.O.; Keller, K.T.; Ralph, W.E.; Trimmer, D.A.

    1987-03-01

    Laboratory measurements of the thermal conductivity and diffusivity of four rock salts, two anhydrites, and two dolomites bordering Cycle 4 and Cycle 5 bedded salt formations in the Permian Basin in Deaf Smith County, Texas, were made in conditions ranging from 303 to 473 K in temperature and 0.1 to 31.0 MPa in hydrostatic confining pressure. Within the +-5% measurement resolution neither conductivity nor diffusivity showed a dependence upon pressure in any of the rocks. Conductivity and diffusivity in all rocks had a negative temperature dependence. For the Cycle 4 salt samples, conductivity fell from 5.5 to 3.75 W/m . K, and diffusivity fell from about 2.7 to 1.7 x 10 -6 m 2 /s. One Cycle 5 salt was a single crystal with anomalous results, but the other had a low conductivity with very weak temperature dependence and a high diffusivity. In the nonsalts, conductivity and diffusivity decreased 10 to 20% over the temperature range explored. In measurements of the coefficient of thermal linear expansion for Cycle 5 salt and nonsalts, the coefficient typically varied from about 12 x 10 -6 K -1 at P = 3.0 MPa to 4 x 10 -6 K -1 at P = 30 MPa for both nonsalt rocks. In anhydrite, it decreased with increasing temperature. In dolomite, the coefficient increased at roughly the same rate. Expansion of the salt ranged from 33 to 38 x 10 -6 K -1 and was independent of pressure and temperature

  6. Gas temperature of capacitance spark discharge in air

    International Nuclear Information System (INIS)

    Ono, Ryo; Nifuku, Masaharu; Fujiwara, Shuzo; Horiguchi, Sadashige; Oda, Tetsuji

    2005-01-01

    Capacitance spark discharge has been widely used for studying the ignition of flammable gas caused by electrostatic discharge. In the present study, the gas temperature of capacitance spark discharge is measured. The gas temperature is an important factor in understanding the electrostatic ignition process because it influences the reaction rate of ignition. Spark discharge is generated in air with a pulse duration shorter than 100 ns. The discharge energy is set to 0.03-1 mJ. The rotational and vibrational temperatures of the N 2 molecule are measured using the emission spectrum of the N 2 second positive system. The rotational and vibrational temperatures are estimated to be 500 and 5000 K, respectively, which are independent of the discharge energy. This result indicates that most of the electron energy is consumed in the excitation of vibrational levels of molecules rather than the heating of the gas. The gas temperature after discharge is also measured by laser-induced fluorescence of OH radicals. It is shown that the gas temperature increases after discharge and reaches approximately 1000 K at 3 μs after discharge. Then the temperature decreases at a rate in the range of 8-35 K/μs depending on the discharge energy

  7. Development of 10kW SOFC module

    Energy Technology Data Exchange (ETDEWEB)

    Hisatome, N.; Nagata, K. [Mitsubishi Heavy Industries, Ltd., Nagasaki (Japan); Kakigami, S. [Electric Power Development Co., Inc., Tokyo (Japan)] [and others

    1996-12-31

    Mitsubishi Heavy industries, Ltd. (MHI) has been developing tubular type Solid Oxide Fuel Cells (SOFC) since 1984. A 1 kW module of SOFC has been continuously operated for 3,000 hours with 2 scheduled thermal cycles at Electric Power Development Co., Inc. (EPDC) Wakamatsu Power Station in 1993. We have obtained of 34% (HHV as H{sub 2}) module efficiency and deterioration rate of 2% Per 1,000 hours in this field test. As for next step, we have developed 10 kW module in 1995. The 10 kW module has been operated for 5,000 hours continuously. This module does not need heating support to maintain the operation temperature, and the module efficiency was 34% (HHV as H{sub 2}). On the other hand, we have started developing the technology of pressurized SOFC. In 1996, pressurized MW module has been tested at MHI Nagasaki Shipyard & Machinery, Works. We are now planning the development of pressurized 10 kW module.

  8. Development of aero-space structural Ni3Al-based alloys for service at temperature above 1000 oC in air without protection coating

    International Nuclear Information System (INIS)

    Kablov, E.N.; Buntushkin, V.P.; Povarova, K.B.; Kasanskaya, N.K.

    2001-01-01

    The principles of alloying are developed for alloys based on the γ' phase Ni 3 Al and realized for the design of a high-temperature alloy VKNA-1V destined for a wide range of 'hot' GTE articles (e.g., flaps, nozzle vanes, turbine rotor blades, elements of flame tubes, and other complex thin-wall articles) produced by vacuum investment casting. Owing to a fortunate combination of the selected boron-free alloying system (Ni-AI-Cr-W-Mo-Zr-C), the presence of a ductile structure constituent such as nickel-based γ solid solution (∼10 wt%) and directed columnar or single crystal structure the alloy is characterized by high ductility at room (El=14-35 %), middle and high temperatures (El=18-31 % at 673-1473 K), by a melting temperature (solidus) as high as T m = 1613 K, a density of at most 7930 kg /m 3 , high short term and long term strength at temperatures 1273-1573 K (σ 100 =110 MPa at 1373 K). Alloy has a high oxidation resistance at temperatures up to 1573 K and is resistant to stress corrosion and general atmospheric corrosion. New VKNA-1V Ni 3 Al-based alloy with equiaxed grained, directional solidification (DS), or single crystal structures can be produced by conventional cast processes used for investment casting of nickel superalloys, including the process of high-gradient DS. Compared to nickel analogs, the alloy is relatively cheap and do not need in protective coating up to 1573 K in air. (author)

  9. Performance of genotype imputation for low frequency and rare variants from the 1000 genomes.

    Science.gov (United States)

    Zheng, Hou-Feng; Rong, Jing-Jing; Liu, Ming; Han, Fang; Zhang, Xing-Wei; Richards, J Brent; Wang, Li

    2015-01-01

    Genotype imputation is now routinely applied in genome-wide association studies (GWAS) and meta-analyses. However, most of the imputations have been run using HapMap samples as reference, imputation of low frequency and rare variants (minor allele frequency (MAF) 1000 Genomes panel) are available to facilitate imputation of these variants. Therefore, in order to estimate the performance of low frequency and rare variants imputation, we imputed 153 individuals, each of whom had 3 different genotype array data including 317k, 610k and 1 million SNPs, to three different reference panels: the 1000 Genomes pilot March 2010 release (1KGpilot), the 1000 Genomes interim August 2010 release (1KGinterim), and the 1000 Genomes phase1 November 2010 and May 2011 release (1KGphase1) by using IMPUTE version 2. The differences between these three releases of the 1000 Genomes data are the sample size, ancestry diversity, number of variants and their frequency spectrum. We found that both reference panel and GWAS chip density affect the imputation of low frequency and rare variants. 1KGphase1 outperformed the other 2 panels, at higher concordance rate, higher proportion of well-imputed variants (info>0.4) and higher mean info score in each MAF bin. Similarly, 1M chip array outperformed 610K and 317K. However for very rare variants (MAF ≤ 0.3%), only 0-1% of the variants were well imputed. We conclude that the imputation of low frequency and rare variants improves with larger reference panels and higher density of genome-wide genotyping arrays. Yet, despite a large reference panel size and dense genotyping density, very rare variants remain difficult to impute.

  10. Comparison of CPR1000 and AP1000 rod position indication systems

    International Nuclear Information System (INIS)

    Lei Qing

    2009-01-01

    This paper introduces the structure, the function, the digital detection principle of reactor control rod position and monitoring systems in CPR1000 and AP1000, comparing with the characteristics of the system design. The results show that the operation mode and function of AP1000 Rod position indication system are similar to that of CPR1000, but AP1000 rod position system provides higher reliability, and reduces the numbers of containment electrical penetrations and is with better characteristics than that of CPR1000, since it incorporated the redundancy design and data communication. (authors)

  11. The development of a cryogenic integrated system with the working temperature of 100K

    Science.gov (United States)

    Liu, En'guang; Wu, Yi'nong; Wang, Yueming; Wen, Jiajia; Lv, Gang; Li, Chunlai; Hou, Jia; Yuan, Liyin

    2016-05-01

    In the infrared system, cooling down the optic components' temperature is a better choice to decrease the background radiation and maximize the sensitivity. This paper presented a 100K cryogenic optical system, for which an integrated designation of mechanical cooler, flexible thermal link and optical bench was developed. The whole infrared optic components which were assembled in a vacuum box were cooled down to 100K by two mechanical coolers. Low thermal conductivity supports and low emissivity multi-layers were used to reduce the cryogenic optical system's heat loss. The experiment results showed that in about eight hours, the temperature of the optical components reached 100K from room temperature, and the vibration from the mechanical coolers nearly have no affection to the imaging process by using of thermal links. Some experimental results of this cryogenic system will be discussed in this paper.

  12. Soot temperature and KL factor for biodiesel and diesel spray combustion in a constant volume combustion chamber

    KAUST Repository

    Zhang, Ji

    2013-07-01

    This paper presents measurements of the soot temperature and KL factor for biodiesel and diesel combustion in a constant volume chamber using a two-color technique. This technique uses a high-speed camera coupled with two narrowband filters (550. nm and 650. nm, 10. nm FWHM). After calibration, statistical analysis shows that the uncertainty of the two-color temperature is less than 5%, while it is about 50% for the KL factor. This technique is then applied to the spray combustion of biodiesel and diesel fuels under an ambient oxygen concentration of 21% and ambient temperatures of 800, 1000 and 1200. K. The heat release result shows higher energy utilization efficiency for biodiesel compared to diesel under all conditions; meanwhile, diesel shows a higher pressure increase due to its higher heating value. Biodiesel yields a lower temperature inside the flame area, a longer soot lift-off length, and a smaller soot area compared to diesel. Both the KL factor and the total soot with biodiesel are lower than with diesel throughout the entire combustion process, and this difference becomes larger as the ambient temperature decreases. Biodiesel shows approximately 50-100. K lower temperatures than diesel at the quasi-steady stage for 1000 and 1200. K ambient temperature, while diesel shows a lower temperature than biodiesel at 800. K ambient. This result may raise the question of how important the flame temperature is in explaining the higher NO. x emissions often observed during biodiesel combustion. Other factors may also play an important role in controlling NO. x emissions. Both biodiesel and diesel temperature measurements show a monotonic dependence on the ambient temperature. However, the ambient temperature appears to have a more significant effect on the soot formation and oxidation in diesel combustion, while biodiesel combustion soot characteristics shows relative insensitivity to the ambient temperature. © 2013 Elsevier Ltd.

  13. Thermal capacity of ternary oxide YBa[sub 2]Cu[sub 3]O[sub 7-y] in 300-1100 K interval. Teploemkost' trojnogo oksida YBa[sub 2]Cu[sub 3]O[sub 7-y] v intervale 300-1100 K

    Energy Technology Data Exchange (ETDEWEB)

    Sharpataya, G A; Ozerova, Z P; Kolnovalova, I A; Lazarev, V B; Shaplygin, I S [AN SSSR, Moscow (Russian Federation). Inst. Obshchej i Neorganicheskoj Khimii

    1991-08-01

    Thermal capacity of YBa[sub 2]Cu[sub 3]O[sub 7-y] samples with different thermal prehistory is measured using a differential scanning calorimeter within 300-1100 K interval. It is shown that the combination of thermal capacity temperature dependence curves in these samples demonstrates reversibility and temperature limits of oxygen absorption and release processes with the corresponding changes of the formular index by oxygen from 6.85-6.90 to 6.35 and vice versa. Thermal capacity anomaly, corresponding to the reversible structural transition from orthorhombic to tetragonal phase with the simultaneous oxygen loss is observed within 630-1000 K interval.

  14. AP1000 station blackout study with and without depressurization using RELAP5/SCDAPSIM

    Energy Technology Data Exchange (ETDEWEB)

    Trivedi, A.K. [Nuclear Engineering and Technology Program, Indian Institute of Technology, Kanpur 208016 (India); Allison, C. [Innovative Systems Software Idaho Falls, ID 83406 (United States); Khanna, A., E-mail: akhanna@iitk.ac.in [Nuclear Engineering and Technology Program, Indian Institute of Technology, Kanpur 208016 (India); Munshi, P. [Nuclear Engineering and Technology Program, Indian Institute of Technology, Kanpur 208016 (India)

    2016-10-15

    maximum core surface temperature is 3096 K and 3236 K for the high pressure and low pressure case; leading to maximum hydrogen generation rate of 0.87 and 9.22 kg/s with total hydrogen generated is 747 and 425 kg respectively. Significant differences in the damage progression have been observed for the two cases. Results also reinforced the fact that surge line fails before vessel failure in case of high pressure scenario.

  15. Leaching Studies on ACR-1000{sup R} Fuel Under Reactor Operating Conditions

    Energy Technology Data Exchange (ETDEWEB)

    Sunder, S. [Atomic Energy of Canada Limited, Fuel and Fuel Channel Safety Branch, Chalk River, Ontario, K0J 1J0 (Canada)

    2009-06-15

    ACR-1000{sup R} is the latest nuclear power reactor being developed by AECL. The ACR-1000 fuel uses a modified CANFLEX{sup R} fuel bundle that contains low-enriched uranium and pellets of burnable neutron absorbers (BNA) in a central element. Dysprosium and gadolinium are used as the burnable neutron absorbers and are present as oxides in a 'fully-stabilized' zirconia matrix. The BNA material in the centre element is designed to limit the coolant void reactivity of the reactor core during postulated loss-of-coolant accidents. As part of the ACR-1000 fuel development, the stability of the BNA material under conditions associated with defects of the Zircaloy sheathing of the BNA central element has been investigated. The results of these tests can be used to demonstrate the phase stability and leaching behaviour of the ACR-1000 fuel under reactor operating conditions. The samples were disks, about 3-4 mm thick, obtained from BNA pellets and Candu fuel (natural uranium UO{sub 2}) pellets (the UO{sub 2} measurements provide a reference point). Leaching tests were carried out in light water at 325 deg. C, above the maximum coolant temperature in an ACR-1000 fuel channel during normal operating conditions (319 deg. C). This temperature also bounds the maximum operating temperature for the current Candu reactors (311 deg. C). The initial pH of the solution (measured at room temperature) used in the leaching tests was 10.3. The leach rates were determined by monitoring the amount of metals leached into solutions. Leaching tests were also carried out with BNA pellet samples in the presence of Zr-2.5%Nb pressure tube coupons to determine the effects, if any, of the presence of pressure tube material on leach rates. Other leaching tests with BNA pellet samples and UO{sub 2} pellets were conducted at 80 deg. C to study the effects of temperature on the leach rates. The temperature of 80 deg. C was selected as representative of typical shutdown temperatures

  16. Preliminary safety evaluation for CSR1000 with passive safety system

    International Nuclear Information System (INIS)

    Wu, Pan; Gou, Junli; Shan, Jianqiang; Zhang, Bo; Li, Xiang

    2014-01-01

    Highlights: • The basic information of a Chinese SCWR concept CSR1000 is introduced. • An innovative passive safety system is proposed for CSR1000. • 6 Transients and 3 accidents are analysed with system code SCTRAN. • The passive safety systems greatly mitigate the consequences of these incidents. • The inherent safety of CSR1000 is enhanced. - Abstract: This paper describes the preliminary safety analysis of the Chinese Supercritical water cooled Reactor (CSR1000), which is proposed by Nuclear Power Institute of China (NPIC). The two-pass core design applied to CSR1000 decreases the fuel cladding temperature and flattens the power distribution of the core at normal operation condition. Each fuel assembly is made up of four sub-assemblies with downward-flow water rods, which is favorable to the core cooling during abnormal conditions due to the large water inventory of the water rods. Additionally, a passive safety system is proposed for CSR1000 to increase the safety reliability at abnormal conditions. In this paper, accidents of “pump seizure”, “loss of coolant flow accidents (LOFA)”, “core depressurization”, as well as some typical transients are analysed with code SCTRAN, which is a one-dimensional safety analysis code for SCWRs. The results indicate that the maximum cladding surface temperatures (MCST), which is the most important safety criterion, of the both passes in the mentioned incidents are all below the safety criterion by a large margin. The sensitivity analyses of the delay time of RCPs trip in “loss of offsite power” and the delay time of RMT actuation in “loss of coolant flowrate” were also included in this paper. The analyses have shown that the core design of CSR1000 is feasible and the proposed passive safety system is capable of mitigating the consequences of the selected abnormalities

  17. Facile synthesis of high-temperature (1000 °C) phase-stable rice-like anatase TiO2 nanocrystals

    Science.gov (United States)

    Lv, Lizhen; Chen, Qirong; Liu, Xiuyun; Wang, Miaomiao; Meng, Xiangfu

    2015-05-01

    High-temperature phase-stable rice-like anatase TiO2 nanocrystals were synthesized by one-pot solvothermal method using soluble titania xerogel and isopropyl alcohol (IPA) as the precursor and the solvent, respectively. Sample characterization was carried out by powder X-ray diffraction, high-resolution transmission electron microscopy, field emission scanning electron microscope, X-ray photoelectron spectroscopy, and N2 adsorption-desorption isotherms. The results showed that TiO2 nanocrystals had rice-like shapes with an average size of 5 nm in width and 35 nm in length. The BET surface area was 153 m2/g. Unexpectedly, the rice-like TiO2 nanocrystals exhibited high-temperature phase stability, which could remain as pure anatase phase after calcinations at 1000 °C. Growth mechanism investigation revealed that the IPA solvent played a key role in nucleation and growth of rice-like anatase TiO2 nanocrystals. The photodegradation of rhodamine B demonstrated that rice-like anatase TiO2 nanocrystals exhibited enhanced photocatalytic activity under visible light irradiation.

  18. ANALISIS KONDISI TERAS REAKTOR DAYA MAJU AP1000 PADA KECELAKAAN SMALL BREAK LOCA

    Directory of Open Access Journals (Sweden)

    Andi Sofrany Ekariansyah

    2015-06-01

    Full Text Available ABSTRAK ANALISIS KONDISI TERAS REAKTOR DAYA MAJU AP1000 PADA KECELAKAAN SMALL BREAK LOCA. Kecelakaan yang diakibatkan oleh kehilangan pendingin (loss of coolant accident / LOCA dari sistem reaktor merupakan kejadian dasar desain yang tetap diantisipasi dalam desain reaktor daya yang mengadopsi teknologi Generasi II hingga IV. LOCA ukuran kecil (small break LOCA memiliki dampak yang lebih signifikan terhadap keselamatan dibandingkan LOCA ukuran besar (large break LOCA seperti terlihat pada kejadian Three-Mile Island (TMI. Fokus makalah adalah pada analisis small break LOCA pada reaktor daya maju Generasi III+ yaitu AP1000 dengan mensimulasikan tiga kejadian pemicu yaitu membukanya katup Automatic Depressurization System (ADS secara tak disengaja, putusnya salah satu pipa Direct Vessel Injection (DVI secara double-ended, dan putusnya pipa lengan dingin dengan diameter bocoran 10 inci. Metode yang digunakan adalah simulasi kejadian pada model AP1000 yang dikembangkan secara mandiri menggunakan program perhitungan RELAP5/SCDAP/Mod3.4. Dampak yang ingin dilihat adalah kondisi teras selama terjadinya small break LOCA yang terdiri dari pembentukan mixture level dan transien temperatur kelongsong bahan bakar. Hasil simulasi menunjukkan bahwa mixture level untuk semua kejadian small break LOCA berada di atas tinggi teras aktif yang menunjukkan tidak terjadinya core uncovery. Adanya mixture level berpengaruh pada transien temperatur kelongsong yang menurun dan menunjukkan pendinginan bahan bakar yang efektif. Hasil di atas juga identik dengan hasil perhitungan program lain yaitu NOTRUMP. Keefektifan pendinginan teras juga disebabkan oleh berfungsinya injeksi pendingin melalui fitur keselamatan pasif yang menjadi ciri reaktor daya AP1000. Secara keseluruhan, hasil analisis menunjukkan model AP1000 yang telah dikembangkan dengan RELAP5 dapat digunakan untuk keperluan analisis kecelakaan dasar desain pada reaktor daya maju AP1000. Kata kunci: analisis

  19. Thermal capacity of ternary oxide YBa2Cu3O7-y in 300-1100 K interval

    International Nuclear Information System (INIS)

    Sharpataya, G.A.; Ozerova, Z.P.; Kolnovalova, I.A.; Lazarev, V.B.; Shaplygin, I.S.

    1991-01-01

    Thermal capacity of YBa 2 Cu 3 O 7-y samples with different thermal prehistory is measured using a differential scanning calorimeter within 300-1100 K interval. It is shown that the combination of thermal capacity temperature dependence curves in these samples demonstrates reversibility and temperature limits of oxygen absorption and release processes with the corresponding changes of the formular index by oxygen from 6.85-6.90 to 6.35 and vice versa. Thermal capacity anomaly, corresponding to the reversible structural transition from orthorhombic to tetragonal phase with the simultaneous oxygen loss is observed within 630-1000 K interval

  20. High-temperature equilibrium vacancy formation in ceramic materials studied by positron annihilation

    International Nuclear Information System (INIS)

    Forster, M.; Claudy, W.; Hermes, H.; Major, J.; Schaefer, H.E.; Koch, M.; Maier, K.; Stoll, H.

    1992-01-01

    Positron lifetime measurements were used in order to study thermal vacancy formation in NiO, YBa 2 Cu 3 O 7-δ , α-Al 2 O 3 , MgO and 6H-SiC at high temperatures. In NiO two increases of the positron trapping rate at 450K and 1200K (po 2 =10 5 Pa) are attributed to the change of charge of neutral extrinsic Ni-vacancies (c ≅ 10 -4 ) into a negative charge state and to the nonstochiometric formation of charged Ni-vacancies at high temperatures. In YBa 2 Cu 3 O 7-δ the oxygen loss or uptake at T > 680K with an activation enthalpy of 1.03eV can be studied by the variation of the positron lifetime with temperature and oxygen partial pressure. In α-Al 2 O 3 the positrons are annihilated from the delocalized free state between 1000K and 2250K and no positron trapping of thermally formed vacancies was detected which may be understood in terms of the theoretically predicted low concentrations of thermal vacancies. In MgO and 6H-SiC positron lifetime measurements were performed up to temperatures of about 2000K

  1. Temperature dependence of the Schottky-barrier heights of n-type semiconductors in the temperature range of 7 to 300 K

    International Nuclear Information System (INIS)

    Chen, T.P.; Lee, T.C.; Fung, S.; Beling, C.D.

    1994-01-01

    In this note we present the results of the temperature dependence of the SBH in Au/n-Si, Ag/n-GaAs, and Au/n-GaAs in the temperature range of 7 to 300 K from our internal photoemission measurements. (orig.)

  2. Density of Liquid Steel over Temperature Range of 1 803-1 873 K

    Institute of Scientific and Technical Information of China (English)

    XIAO Feng; FANG Liang

    2004-01-01

    The density of three kinds of liquid steel was measured by a modified sessile drop method over the temperature range of 1 803-1 873 K. It is found that the density of liquid steels decreases with increasing temperature and carbon content in steel. Both of the density and its absolute temperature coefficient of studied steels are smaller than the literature values of pure iron. The molar volume of the steels increases with increasing temperature.

  3. EPR reversible signature of self-trapped holes in fictive temperature-treated silica glass

    Science.gov (United States)

    Lancry, Matthieu; Ollier, Nadège; Babu, B. H.; Herrero, Christian; Poumellec, Bertrand

    2018-03-01

    Post-mortem electron paramagnetic resonance spectroscopy experiments have been carried out between room temperature and 20 K to examine the radiation-induced defects in fictive temperature (Tf) treated Heraeus F300 silica (0.1 ppm OH, 1500 ppm Cl2). In particular, we focus our attention on Self-Trapped Hole (STH) centers detected in 1000 °C, 1100 °C, and 1200 °C Tf treated samples irradiated at room temperature by gamma rays at 6 kGy. By repeating annealing cycles between 77 and 300 K on the same samples, we observed that the EPR signal attributed to STH decreases as the temperature increases but in a reversible manner. We evidenced a deviation from the Curie law for T > 70 K and suggested an interpretation based on the decrease in the "strain-assisted TH" population by reversible excitation of the trapped hole to a delocalized state with an activation energy of 7.8 meV. This also means that the precursors of hole trapping sites (a local strain atomic configuration) remain stable until 300 K at least.

  4. Renormings of C(K) spaces

    Czech Academy of Sciences Publication Activity Database

    Smith, Richard James; Troyanski, S.

    2010-01-01

    Roč. 104, č. 2 (2010), s. 375-412 ISSN 1578-7303 R&D Projects: GA ČR GA201/07/0394 Institutional research plan: CEZ:AV0Z10190503 Keywords : uniformly rotund norms * Frechet * Gateaux Subject RIV: BA - General Mathematics Impact factor: 0.400, year: 2010 http://www.springerlink.com/content/430027876375w58x/

  5. Analysis of optimal design of low temperature economizer

    Science.gov (United States)

    Song, J. H.; Wang, S.

    2017-11-01

    This paper has studied the Off-design characteristic of low temperature economizer system based on thermodynamics analysis. Based on the data from one 1000 MW coal-fired unit, two modes of operation are contrasted and analyzed. One is to fix exhaust gas temperature and the other one is to take into account both of the average temperature difference and the exhaust gas temperature. Meanwhile, the cause of energy saving effect change is explored. Result shows that: in mode 1, the amount of decrease in coal consumption reduces from 1.11 g/kWh (under full load) to 0.54 g/kWh (under half load), and in mode 2, when the load decreases from 90% to 50%, the decrease in coal consumption reduces from 1.29 g/kWh to 0.84 g/kWh. From the result, under high load, the energy saving effect is superior, and under lower work load, energy saving effect declines rapidly when load is reduced. When load changes, the temperature difference of heat transfer, gas flow, the flue gas heat rejection and the waste heat recovery change. The energy saving effect corresponding changes result in that the energy saving effect under high load is superior and more stable. However, rational adjustment to the temperature of outlet gas can alleviate the decline of the energy saving effect under low load. The result provides theoretical analysis data for the optimal design and operation of low temperature economizer system of power plant.

  6. Partitioning of K, Cl, S and P during combustion of poplar and brassica energy crops

    DEFF Research Database (Denmark)

    Díaz-Ramírez, Maryori; Jappe Frandsen, Flemming; Glarborg, Peter

    2014-01-01

    K-, Cl-, S- and P-release from a herbaceous (brassica) and a short rotation coppice (poplar) cultivated in the Mediterranean region, have been investigated under combustion conditions [500-1100 °C]. Contrary to brassica, Cl- and S-release from poplar were substantial for all temperatures tested....... Low-temperature [500-700 °C] Cl-release from the high-Cl brassica appeared to be primarily limited by the fuel chemical composition and secondarily by interactions of the ash-forming elements with the fuel organic matrix. Below 700 °C, Cl-release was nearly 50%, whereas complete dechlorination...... resulted around 800 °C. S-release from brassica was up to 40% at low temperature. Above 1000 °C, additional S-release was observed presumably by sulfate dissociation. K-release was linked to Cl-release around 700 °C and, gradually increased afterwards. At 1100 °C, nearly 60% of K in poplar was retained...

  7. Response characteristics of HPR1000 primary circuit under different working conditions of the atmospheric relief system after SBLOCA

    Energy Technology Data Exchange (ETDEWEB)

    Sui, Danting, E-mail: suidanting@163.com [School of Nuclear Science and Engineering, North China Electric Power University, Beijing (China); Beijing Key Laboratory of Passive Safety Technology for Nuclear Energy, North China Electric Power University, Beijing (China); Lu, Daogang [School of Nuclear Science and Engineering, North China Electric Power University, Beijing (China); Beijing Key Laboratory of Passive Safety Technology for Nuclear Energy, North China Electric Power University, Beijing (China); Shang, Changzhong; Wei, Yuanyuan [China Nuclear Power Design Co., ltd (ShenZhen), Shenzhen (China); Zhang, Xianjie [School of Nuclear Science and Engineering, North China Electric Power University, Beijing (China); Beijing Key Laboratory of Passive Safety Technology for Nuclear Energy, North China Electric Power University, Beijing (China)

    2017-04-01

    Highlights: • Response of HPR1000 under different VDA conditions after SBLOCA was investigated. • Activation of VDA can trigger ACCU SI earlier with a critical point exists. • VDA capability design should compromise the critical point with reactivity feedback. - Abstract: To cope with SBLOCA in absence of High-Head Safety Injection (HHSI) from design of HPR1000, atmospheric relief system (originally named as VDA in French) is uniquely designed to help to trigger Middle Head Safety Injection (MHSI) or Low Head Safety Injection (LHSI) earlier through cooling primary system quickly after SBLOCA. To make the best use of VDA decay heat removal capability, primary and secondary system of HPR1000 was modeled with RELAP5/SCDAP computer code. After steady-state initialization, a cold leg 30 mm break SBLOCA was simulated with six simulation conditions and five additional cases including availability of ACCU, different VDA discharge locations and area. Response characteristics of primary loop under different VDA working conditions are investigated. Pressurizer pressure decreases rapidly to lower level to trigger the reactor scram, VDA activation and accumulator safety injection sequently. Peak cladding temperature is 899.45 K occurring at 222 s, which is far below the safety limit. Activation of VDA can trigger ACCU SI earlier with a critical point, while positive reactivity will be introduced due to negative moderator temperature effect and Doppler effect. Larger VDA discharge capability will introduce larger reactivity feedback, as well as induce lower core level and SG level. It's suggested that VDA discharge condition should be chosen before the critical point, with the compromise with reactivity feedback introduced due to the negative moderator temperature effect.

  8. Response characteristics of HPR1000 primary circuit under different working conditions of the atmospheric relief system after SBLOCA

    International Nuclear Information System (INIS)

    Sui, Danting; Lu, Daogang; Shang, Changzhong; Wei, Yuanyuan; Zhang, Xianjie

    2017-01-01

    Highlights: • Response of HPR1000 under different VDA conditions after SBLOCA was investigated. • Activation of VDA can trigger ACCU SI earlier with a critical point exists. • VDA capability design should compromise the critical point with reactivity feedback. - Abstract: To cope with SBLOCA in absence of High-Head Safety Injection (HHSI) from design of HPR1000, atmospheric relief system (originally named as VDA in French) is uniquely designed to help to trigger Middle Head Safety Injection (MHSI) or Low Head Safety Injection (LHSI) earlier through cooling primary system quickly after SBLOCA. To make the best use of VDA decay heat removal capability, primary and secondary system of HPR1000 was modeled with RELAP5/SCDAP computer code. After steady-state initialization, a cold leg 30 mm break SBLOCA was simulated with six simulation conditions and five additional cases including availability of ACCU, different VDA discharge locations and area. Response characteristics of primary loop under different VDA working conditions are investigated. Pressurizer pressure decreases rapidly to lower level to trigger the reactor scram, VDA activation and accumulator safety injection sequently. Peak cladding temperature is 899.45 K occurring at 222 s, which is far below the safety limit. Activation of VDA can trigger ACCU SI earlier with a critical point, while positive reactivity will be introduced due to negative moderator temperature effect and Doppler effect. Larger VDA discharge capability will introduce larger reactivity feedback, as well as induce lower core level and SG level. It's suggested that VDA discharge condition should be chosen before the critical point, with the compromise with reactivity feedback introduced due to the negative moderator temperature effect.

  9. Accelerated test techniques for micro-circuits: Evaluation of high temperature (473 k - 573 K) accelerated life test techniques as effective microcircuit screening methods

    Science.gov (United States)

    Johnson, G. M.

    1976-01-01

    The application of high temperature accelerated test techniques was shown to be an effective method of microcircuit defect screening. Comprehensive microcircuit evaluations and a series of high temperature (473 K to 573 K) life tests demonstrated that a freak or early failure population of surface contaminated devices could be completely screened in thirty two hours of test at an ambient temperature of 523 K. Equivalent screening at 398 K, as prescribed by current Military and NASA specifications, would have required in excess of 1,500 hours of test. All testing was accomplished with a Texas Instruments' 54L10, low power triple-3 input NAND gate manufactured with a titanium- tungsten (Ti-W), Gold (Au) metallization system. A number of design and/or manufacturing anomalies were also noted with the Ti-W, Au metallization system. Further study of the exact nature and cause(s) of these anomalies is recommended prior to the use of microcircuits with Ti-W, Au metallization in long life/high reliability applications. Photomicrographs of tested circuits are included.

  10. Low temperature electron beam irradiation effects on the lactate dehydrogenase activity

    International Nuclear Information System (INIS)

    Catana, D.; Hategan, Alina; Oproiu, C.; Popescu, Alina; Hategan, Dora; Morariu, V. V.

    1998-01-01

    The direct and indirect effects of 5 MeV electron beam irradiation in the range 0-400 Gy at 20 deg. C, -3 deg. C and -196 deg. C on the global enzymatic activity of lactate dehydrogenase (LDH) have been studied. Our results showed a monoexponential decrease in the enzymatic activity of irradiated LDH at all irradiation temperatures independently of direct or indirect action of radiation. The temperature gradient used to lower the temperature of the samples to -196 deg. C drastically influences the results. Our data suggest that freeze-thawing in two steps down to -196 deg. C make LDH insensitive to irradiation, while one step freeze-thawing procedure results in a gradual activity loss with increasing dose irradiation. This data can be interpreted in terms of different conformational changes during the particular freeze-thawing process. (authors)

  11. Investigation of the niobium-oxygen system under low pressure and between 550 K and 2350 K: solid solution, surface overlay and reactivity

    International Nuclear Information System (INIS)

    Jupille, Jacques

    1974-09-01

    This research thesis addresses the behaviour of transition metals when interacting with oxygen, more particularly in the case of phase formation, but also adsorption and desorption which occur in the case of interaction with low pressure oxygen. It focuses on the case of niobium in solid solution. After a description of phases present in the niobium-oxygen system, and a discussion of reactivities of oxygen and water vapour, the author describes the experimental methods (apparatus and installations, samples, measured values), discusses the study of the surface-volume transfer constant of the niobium-oxygen solution, and the niobium-oxygen interaction mechanisms at high (superior to 1700 K) and low (inferior to 1000 K) temperatures: oxide desorption, oxygen reaction kinetics

  12. Water solubility of synthetic pyrope at high temperature and pressure up to 12GPa

    Science.gov (United States)

    Huang, S.; Chen, J.

    2012-12-01

    Water can be incorporated into normally anhydrous minerals as OH- defects and transported into the mantle. Its existence in the mantle may affect property of minerals, such as elasticity, electrical conductivity and rheological properties. As the secondary mineral in the mantle, garnet has not been extensively studied for its water solubility and there is discrepancies among the existing experiments on the water solubility in the garnet change at pressures and temperatures. Geiger et al., 1991 investigated water content in synthetic pyrope and concluded 0.02wt% to 0.07wt% OH- substitution. Lu et al., 1997 found 198ppm water in the Dora Miara pyrope at 100Kbar and 1000°C. Withers et al., 1998 claimed that water solubility in pyrope reached 1000ppm at 5GPa and then decreased as pressure increasing; above 7GPa, no water was detected. Mookherjee et al., 2009 also explored pyrope-rich garnet, which contains water up to 0.1%wt at 5-9GPa and temperatures 1373K-1473K. Here we report a study of water solubility of synthetic single crystal pyrope at pressures 4-12GPa and temperature 1000°C. Single crystals of pyrope were synthesized using multi-anvil press and water contents in these samples were measured using FTIR. We have observed OH- peak at 3650 cm-1 along this pressure range, although Withers, 1998 reported water contents decrease to undetectable level above 7GPa. Water solubility in pyrope will be reported as a function of pressure up to 12 GPa at 1000°C.

  13. W-Band InP Wideband MMIC LNA with 30K Noise Temperature

    Science.gov (United States)

    Weinreb, S.; Lai, R.; Erickson, N.; Gaier, T.; Wielgus, J.

    2000-01-01

    This paper describe a millimeter wave low noise amplifier with extraordinary low noise, low consumption, and wide frequency range. These results are achieved utilizing state-of-the-art InP HEMT transistors coupled with CPW circuit design. The paper describes the transistor models, modeled and measured on-wafer and in-module results at both 300K am 24K operating temperatures for many samples of the device.

  14. Horizontal steam generator PGV-1000 thermal-hydraulic analysis

    Energy Technology Data Exchange (ETDEWEB)

    Ubra, O. [Skoda Company, Prague (Switzerland); Doubek, M. [Czech Technical Univ., Prague (Switzerland)

    1995-12-31

    A computer program for the steady state thermal-hydraulic analysis of horizontal steam generator PGV-1000 is presented. The program provides the capability to analyze steam generator PGV-1000 primary side flow and temperature distribution, primary side pressure drops, heat transfer between the primary and secondary sides and multidimensional heat flux distribution. A special attention is paid to the thermal-hydraulics of the secondary side. The code predicts 3-D distribution of the void fraction at the secondary side, mass redistribution under the submerged perforated sheet and the steam generator level profile. By means of developed computer program a detailed thermal-hydraulic study of the PGV-1000 has been carried out. A wide range of calculations has been performed and a set of important steam generator characteristics has been obtained. Some of them are presented in the paper. (orig.). 5 refs.

  15. Horizontal steam generator PGV-1000 thermal-hydraulic analysis

    International Nuclear Information System (INIS)

    Ubra, O.; Doubek, M.

    1995-01-01

    A computer program for the steady state thermal-hydraulic analysis of horizontal steam generator PGV-1000 is presented. The program provides the capability to analyze steam generator PGV-1000 primary side flow and temperature distribution, primary side pressure drops, heat transfer between the primary and secondary sides and multidimensional heat flux distribution. A special attention is paid to the thermal-hydraulics of the secondary side. The code predicts 3-D distribution of the void fraction at the secondary side, mass redistribution under the submerged perforated sheet and the steam generator level profile. By means of developed computer program a detailed thermal-hydraulic study of the PGV-1000 has been carried out. A wide range of calculations has been performed and a set of important steam generator characteristics has been obtained. Some of them are presented in the paper. (orig.)

  16. Horizontal steam generator PGV-1000 thermal-hydraulic analysis

    Energy Technology Data Exchange (ETDEWEB)

    Ubra, O [Skoda Company, Prague (Switzerland); Doubek, M [Czech Technical Univ., Prague (Switzerland)

    1996-12-31

    A computer program for the steady state thermal-hydraulic analysis of horizontal steam generator PGV-1000 is presented. The program provides the capability to analyze steam generator PGV-1000 primary side flow and temperature distribution, primary side pressure drops, heat transfer between the primary and secondary sides and multidimensional heat flux distribution. A special attention is paid to the thermal-hydraulics of the secondary side. The code predicts 3-D distribution of the void fraction at the secondary side, mass redistribution under the submerged perforated sheet and the steam generator level profile. By means of developed computer program a detailed thermal-hydraulic study of the PGV-1000 has been carried out. A wide range of calculations has been performed and a set of important steam generator characteristics has been obtained. Some of them are presented in the paper. (orig.). 5 refs.

  17. Reaction rate constants of HO2 + O3 in the temperature range 233-400 K

    Science.gov (United States)

    Wang, Xiuyan; Suto, Masako; Lee, L. C.

    1988-01-01

    The reaction rate constants of HO2 + O3 were measured in the temperature range 233-400 K using a discharge flow system with photofragment emission detection. In the range 233-253 K, the constants are approximately a constant value, and then increase with increasing temperature. This result suggests that the reaction may have two different channels. An expression representing the reaction rate constants is presented.

  18. Solvent Effects in the Electroreduction of Ferrocene at Pt in the Temperature Range 200-300 K

    Science.gov (United States)

    1991-03-20

    been obtained at iow temperatures downto 92 K ata P ulramcroeectode(dimete, 2 pm inthree alcohol solvents, namely, methanol, ethanol , and n-propanol. In...In this aree.-doutee-eace&4 Kinetic parameters for the electrooxidation of ferrocene have been obtained at low temperatures down to 193 ’K at a Pt...with solvent nature. tnsvetsiky of~aitm Davis, CA 95616 Kinetic data obtained in mteehanol, ethanol . and I1- propanol as a function of temperature

  19. THE BINARITY OF MILKY WAY F,G,K STARS AS A FUNCTION OF EFFECTIVE TEMPERATURE AND METALLICITY

    Energy Technology Data Exchange (ETDEWEB)

    Gao, Shuang; Liu, Chao; Zhang, Xiaobin; Justham, Stephen; Deng, Licai; Yang, Ming [Key Laboratory of Optical Astronomy, National Astronomical Observatories, Chinese Academy of Sciences, Beijing 100012 (China)

    2014-06-20

    We estimate the fraction of F,G,K stars with close binary companions by analysing multi-epoch stellar spectra from the Sloan Digital Sky Survey (SDSS) and LAMOST for radial velocity variations. We employ a Bayesian method to infer the maximum likelihood of the fraction of binary stars with orbital periods of 1000 days or shorter, assuming a simple model distribution for a binary population with circular orbits. The overall inferred fraction of stars with such a close binary companion is 43.0% ± 2.0% for a sample of F,G,K stars from SDSS SEGUE, and 30% ± 8.0% in a similar sample from LAMOST. The apparent close binary fraction decreases with the stellar effective temperature. We divide the SEGUE and LEGUE data into three subsamples with different metallicity ([Fe/H] < –1.1; –1.1 < [Fe/H] < –0.6; –0.6 < [Fe/H]), for which the inferred close binary fractions are 56 ± 5.0%, 56.0 ± 3%, and 30 ± 5.7%. The metal-rich stars from our sample are therefore substantially less likely to possess a close binary companion than otherwise similar stars drawn from metal-poor populations. The different ages and formation environments of the Milky Way's thin disk, thick disk, and halo may contribute to explaining these observations. Alternatively, metallicity may have a significant effect on the formation and/or evolution of binary stars.

  20. Thermogravimetric analysis of silicon carbide-silicon nitride fibers at ambient to 1000 C in air

    Science.gov (United States)

    Daniels, J. G.; Ledbetter, F. E., III; Clemons, J. M.; Penn, B. G.

    1984-01-01

    Thermogravimetric analysis of silicon carbide-silicon nitride fibers was carried out at ambient to 1000 C in air. The weight loss over this temperature range was negligible. In addition, the oxidative stability at high temperature for a short period of time was determined. Fibers heated at 1000 C in air for fifteen minutes showed negligible weight loss (i.e., less than 1 percent).

  1. Thermal properties of Na2MoO4(s) and Na2Mo2O7(s) by high-temperature Calvet calorimetry in the temperature range 335 K to 760 K

    International Nuclear Information System (INIS)

    Iyer, V.S.; Agarwal, Renu; Roy, K.N.; Venkateswaran, R.S.; Venugopal, V.; Sood, D.D.

    1990-01-01

    Enthalpy increment measurements were made on Na 2 MoO 4 and Na 2 Mo 2 O 7 in the temperature range 335 K to 760 K by the drop method using a high-temperature Calvet calorimeter. The calorimeter was calibrated using an electrical method and synthetic sapphire SRM-720(Al 2 O 3 ). An on-line computer was used for acquiring and processing results from the calorimeter. The enthalpy increments for Na 2 MoO 4 and Na 2 Mo 2 O 7 were least-squares fitted to a polynomial with temperature and are given. The thermal properties of Na 2 MoO 4 and Na 2 Mo 2 O 7 were obtained using the above experimental values. These are the first experimental results on the thermal properties of these compounds. (author)

  2. Preparation and Characterization of K2CO3-Activated Kraft Lignin Carbon

    Directory of Open Access Journals (Sweden)

    Xian-fa Li

    2016-01-01

    Full Text Available A series of activated carbons (ACs were prepared by K2CO3 activation from kraft lignin (KL that was recovered from papermaking black liquor. The effects of process parameters such as the activation temperature (AT, activated period, K2CO3 to KL mass ratio, and N2 flow rate on the characteristics of the final product were determined. The ACs were characterized using nitrogen adsorption, morphology, and fractal dimension analyses. The results showed that the AT was the main factor influencing the yield, surface area, and pore structure. The yield of ACs obviously decreased from 50.6% to 20.5% with increasing AT from 600 °C to 1000 °C, and decreased with increasing K2CO3/KL mass ratio. Activation time and N2 flow rate had slight effect on the yield of ACs. The surface area and total pore volume increased as the AT rose to 900 °C and then decreased with further increases in temperature. The maximum surface area and total pore volume were 1816.3 m2/g and 1.26 cm3/g, respectively, at a K2CO3 to KL mass ratio of 3:1, AT of 900 °C, activation time of 2 h, and N2 flow rate of 70 cm3/min. The pore structure of the ACs could be tailored by controlling the AT. As the AT was increased from 700 to 1000 °C, the mesoporosity increased from 11.6% to 95.9%. SEM images indicated that the morphology of ACs was modified by the AT. The K2CO3 was partially recycled.

  3. Effects of ambient oxygen concentration on soot temperature and concentration for biodiesel and diesel spray combustion

    KAUST Repository

    Zhang, Ji; Jing, Wei; Roberts, William L.; Fang, Tiegang

    2015-01-01

    during biodiesel and diesel spray combustion. The experiment was implemented in a constant volume chamber system, where the ambient oxygen concentration varied from 21 to 10% and the ambient temperature was kept to 1,000 K. A high speed two-color

  4. Simultaneous temperature measurement of ionospheric plasma and neutral atmosphere with K-10-11 rocket

    International Nuclear Information System (INIS)

    Murasato, Yukio; Kaneko, Osamu; Sasaki, Susumu; Kawashima, Nobuki; Kibune, Tadashi.

    1976-01-01

    Ion temperature and neutral atmospheric temperature in lower ionospheric layer were measured by the ''Shadow Method'', which has been developed and improved by the authors. The principle of the method, which utilizes the fact that the shadow due to the reduction of density of medium behind on obstacle depends upon the flow velocity and the temperature of the medium, is briefly explained together with the apparatus used for the measurement. A pair of the Langmuir probes with the interval of 44 mm was used for the measurement of ion temperature. For the measurement of the neutral atmospheric temperature, its density was measured with the ionization gauge. The measuring system was mounted on the K-10-11 rocket, and launched from KSC at 2 p.m., September 24, 1975. Although the rocket itself reached its highest altitude of 196 km, the temperature measurement was performed between the altitude of 80 km and 140 km. The measured temperatures of ions, neutral atmosphere, and electrons are presented as the functions of altitude. It is confirmed that the temperatures of ions and neutral atmosphere are lower than that of electrons in that range of altitude. (Aoki, K.)

  5. Microwave absorption properties of flake-shaped Co particles composites at elevated temperature (293-673 K) in X band

    Science.gov (United States)

    Wang, Guowu; Li, Xiling; Wang, Peng; Zhang, Junming; Wang, Dian; Qiao, Liang; Wang, Tao; Li, Fashen

    2018-06-01

    The complex permeability and permittivity of the easy-plane anisotropic Co/polyimide composite at high temperature (293-673 K) in X band were measured. The results show that both the complex permeability and permittivity increase with the increase of temperature in the measured temperature range. The calculated absorption properties display that the intensity of the reflection loss (RL) peak first increases and then decreases with the increase of temperature, and reaches the maximum (-52 dB) at 523 K. At each temperature, the composite can achieve the RL exceeding -10 dB in the whole X band. The composite can even work stably for more than 20 min with the excellent absorption performance under 673 K. In addition, the RL performance of the composite at high temperature is better than that at room temperature.

  6. Collecting the Missing Piece of the Puzzle: The Wind Temperatures of Arcturus (K2 III) and Aldeberan (K5 III)

    Science.gov (United States)

    Harper, Graham

    2017-08-01

    Unravelling the poorly understood processes that drive mass loss from red giant stars requires that we empirically constrain the intimately coupled momentum and energy balance. Hubble high spectral resolution observations of wind scattered line profiles, from neutral and singly ionized species, have provided measures of wind acceleration, turbulence, terminal speeds, and mass-loss rates. These wind properties inform us about the force-momentum balance, however, the spectra have not yielded measures of the much needed wind temperatures, which constrain the energy balance.We proposed to remedy this omission with STIS E140H observations of the Si III 1206 Ang. resonance emission line for two of the best studied red giants: Arcturus (alpha Boo: K2 III) and Aldebaran (alpha Tau: K5 III), both of which have detailed semi-empirical wind velocity models. The relative optical depths of wind scattered absorption in Si III 1206 Ang., O I 1303 Ang. triplet., C II 1335 Ang., and existing Mg II h & k and Fe II profiles give the wind temperatures through the thermally controlled ionization balance. The new temperature constraints will be used to test existing semi-empirical models by comparision with multi-frequency JVLA radio fluxes, and also to constrain the flux-tube geometry and wave energy spectrum of magnetic wave-driven winds.

  7. Temperature setting and thermal regulation system for liquid hydrogen bubble chamber; Systeme de mise en temperature et de regulation thermique de chambres a bulles a hydrogene liquide

    Energy Technology Data Exchange (ETDEWEB)

    Meyer, J; Prugne, P; Roubeau, P [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1961-07-01

    Hydrogen bubble chamber cooling and constant temperature maintenance in the 25/28 deg. K, range by means of liquid hydrogen boiling under atmospheric pressure (20.4 deg. K) need a device, if possible automatic allowing the introduction of a variable amount of cold to counterbalance the heat transfer either static or due to the chamber operation. A variable impedance heat exchanger has been designed, built and experimented for this purpose. This device, which takes little space (less than 1000 cm{sup 3}) allows transfer of a variable cold power between 0 and 500 watts (0 to 50 liter of evaporated hydrogen). (author) [French] Pour le refroidissement des chambres a bulles a hydrogene et pour le maintien d'une temperature constante dans la gamme 25/28 deg. K au moyen d'hydrogene a l'ebullition sous pression atmospherique (20,4 deg. K), on a besoin d'un dispositif, si possible automatique, permettant l'introduction d'une quantite variable de froid pour compenser le transfert de chaleur, soit statique, soit du a l'operation de la chambre. Un echangeur de chaleur a impedance variable a ete concu, construit et essaye pour cet usage. Ce dispositif qui est peu encombrant (en dessous de 1000 cm{sup 3} ) permet le transfert d'une puissance frigorifique, variable entre 0 et 500 watts (0 a 50 litres d'hydrogene evapore). (auteur)

  8. Difference of reactor core nuclear instrument between AP1000 and CPR1000

    International Nuclear Information System (INIS)

    Zhang Shidong; Zhou Can; Deng Tian

    2014-01-01

    As a typical generation Ⅲ reactor technique, the AP1000 applies many advanced design concepts, simplifies the design, reduces equipment quantities, and thus enhances systematic reliability. The comparison of reactor core measurement instrument differences between AP1000 and CPR1000 from several aspects was involved in the paper. Through analysis and comparison of these differences, passive design concepts and characteristics of AP1000 are familiarized, and conveniences for staffs engaged in CPR1000 to learn and grasp AP1000 technique are provided. It is useful in reactor start up, operation and maintenance. (authors)

  9. L1000CDS2: LINCS L1000 characteristic direction signatures search engine.

    Science.gov (United States)

    Duan, Qiaonan; Reid, St Patrick; Clark, Neil R; Wang, Zichen; Fernandez, Nicolas F; Rouillard, Andrew D; Readhead, Ben; Tritsch, Sarah R; Hodos, Rachel; Hafner, Marc; Niepel, Mario; Sorger, Peter K; Dudley, Joel T; Bavari, Sina; Panchal, Rekha G; Ma'ayan, Avi

    2016-01-01

    The library of integrated network-based cellular signatures (LINCS) L1000 data set currently comprises of over a million gene expression profiles of chemically perturbed human cell lines. Through unique several intrinsic and extrinsic benchmarking schemes, we demonstrate that processing the L1000 data with the characteristic direction (CD) method significantly improves signal to noise compared with the MODZ method currently used to compute L1000 signatures. The CD processed L1000 signatures are served through a state-of-the-art web-based search engine application called L1000CDS 2 . The L1000CDS 2 search engine provides prioritization of thousands of small-molecule signatures, and their pairwise combinations, predicted to either mimic or reverse an input gene expression signature using two methods. The L1000CDS 2 search engine also predicts drug targets for all the small molecules profiled by the L1000 assay that we processed. Targets are predicted by computing the cosine similarity between the L1000 small-molecule signatures and a large collection of signatures extracted from the gene expression omnibus (GEO) for single-gene perturbations in mammalian cells. We applied L1000CDS 2 to prioritize small molecules that are predicted to reverse expression in 670 disease signatures also extracted from GEO, and prioritized small molecules that can mimic expression of 22 endogenous ligand signatures profiled by the L1000 assay. As a case study, to further demonstrate the utility of L1000CDS 2 , we collected expression signatures from human cells infected with Ebola virus at 30, 60 and 120 min. Querying these signatures with L1000CDS 2 we identified kenpaullone, a GSK3B/CDK2 inhibitor that we show, in subsequent experiments, has a dose-dependent efficacy in inhibiting Ebola infection in vitro without causing cellular toxicity in human cell lines. In summary, the L1000CDS 2 tool can be applied in many biological and biomedical settings, while improving the extraction of

  10. Temperature detectors on irradiated silicon base

    International Nuclear Information System (INIS)

    Karimov, M.; Dzhalelov, M.A.; Kurbanov, A.O.

    2005-01-01

    It is well known, that the most suitable for thermal resistors production is compensated silicon with impurities forming deep lying in forbidden zone, having big negative resistance temperature coefficients (RTC). In the capacity of initial materials for thermal resistors with negative RTC the n-type monocrystalline silicon with specific resistance ∼30 Ω·cm at 300 K is applied. Before the irradiation the phosphorus diffusion is realizing at temperature1000 deg. C for 10 min. Irradiation is putting into practise by WWR-SM reactor fast neutrons within the range (7-10)·10 13 cm -2 . The produced resistors have nominal resistance range (8-20)·10 3 Ω·cm, coefficient of the thermal sensitivity B=4000-6000 deg. C., RTC α 300K =4-6.6 %/grad. It is shown, that offered method allows to obtain same type resistors characteristics on the base of neutron-irradiated material

  11. Experimental study of the density and viscosity of polyethylene glycols and their mixtures at temperatures from 293 K to 473 K and at atmospheric pressure

    International Nuclear Information System (INIS)

    Sagdeev, D.I.; Fomina, M.G.; Mukhamedzyanov, G.Kh.; Abdulagatov, I.M.

    2011-01-01

    Highlights: → Viscosity and density of polyethylene glycols. → Combined experimental apparatus for density and viscosity measurements. → Vogel-Tamman-Fulcher model for viscosity. - Abstract: A new apparatus to measure simultaneously the density and viscosity of liquids has been designed and constructed based on the hydrostatic weighing and falling-body principles. The density and viscosity of monoethylene glycol (MEG), diethylene glycol (DEG), and triethylene glycol (TEG) and their binary, (50%MEG + 50%DEG), (50%MEG + 50%TEG), (50%DEG + 50%TEG), and ternary (33.33%MEG + 33.33%DEG + 33.34%TEG) mixtures have been measured over the temperature range from 293 K to 473 K and at atmospheric pressure. The expanded uncertainty of the density, pressure, temperature, and viscosity measurements at the 95% confidence level with a coverage factor of k = 2 is estimated to be 0.15% to 0.30%, 0.05%, 0.06 K, and 1.5% to 2.0% (depending on temperature and pressure ranges), respectively. The theoretically based Arrhenius-Andrade and Vogel-Tamman-Fulcher type equations were used to describe the temperature dependence of measured viscosities for pure polyethylene glycols and their mixtures.

  12. Test results of full-scale high temperature superconductors cable models destined for a 36 kV, 2 kA(rms) utility demonstration

    DEFF Research Database (Denmark)

    Daumling, M.; Rasmussen, C.N.; Hansen, F.

    2001-01-01

    Power cable systems using high temperature superconductors (HTS) are nearing technical feasibility. This presentation summarises the advancements and status of a project aimed at demonstrating a 36 kV, 2 kA(rms) AC cable system by installing a 30 m long full-scale functional model in a power...

  13. Propargyl Recombination: Estimation of the High Temperature, Low Pressure Rate Constant from Flame Measurements

    DEFF Research Database (Denmark)

    Rasmussen, Christian Lund; Skjøth-Rasmussen, Martin Skov; Jensen, Anker

    2005-01-01

    The most important cyclization reaction in hydrocarbon flames is probably recombination of propargyl radicals. This reaction may, depending on reaction conditions, form benzene, phenyl or fulvene, as well as a range of linear products. A number of rate measurements have been reported for C3H3 + C3H......3 at temperatures below 1000 K, while data at high temperature and low pressure only can be obtained from flames. In the present work, an estimate of the rate constant for the reaction at 1400 +/- 50 K and 20 Torr is obtained from analysis of the fuel-rich acetylene flame of Westmoreland, Howard...

  14. Oxidation-induced deformation of zircaloy-4 tubing in steam in the temperature range 600-1000 degree C

    International Nuclear Information System (INIS)

    Aly, A.E.; Hussein, A.G.; EL-Raghy, S.M.; EL-Sayed, A.A.; EL-Banna, O.A.

    1992-01-01

    The oxidation-induced deformation of zircaloy-4 (zry-4) tubing in steam has been studied in the temperature range 600 to 1000 degree C. The induced deformation has been measured in both radial and axial directions of the tube. The effect of hydrogen addition to steam was also investigated. The oxidation-induced deformation has been characterized by uniform and non-uniform (distortion) strain period. During the uniform strain period the radial strain kinetics were found in general, to be parallel to the oxidation kinetics. The axial strain (δA) induced by oxidation was found to be always lower than the radial strain (εR). The addition of 5% by volume hydrogen to steam leads to an increase in the oxidation rate and to a decrease in the degree of anisotropy between radial and axial strains

  15. Mechanism and Influencing Factors of Iron Nuggets Forming in Rotary Hearth Furnace Process at Lower Temperature

    Science.gov (United States)

    Han, Hongliang; Duan, Dongping; Chen, Siming; Yuan, Peng

    2015-10-01

    In order to improve the efficiency of slag and iron separation, a new idea of "the separation of slag (solid state) and iron (molten state) in rotary hearth furnace process at lower temperature" is put forward. In this paper, the forming process of iron nuggets has been investigated. Based on those results, the forming mechanisms and influencing factors of iron nugget at low temperature are discussed experimentally using an electric resistance furnace simulating a rotary hearth furnace process. Results show that the reduction of iron ore, carburization of reduced iron, and the composition and quantity of slag are very important for producing iron nuggets at lower temperature. Reduction reaction of carbon-containing pellets is mainly at 1273 K and 1473 K (1000 °C and 1200 °C). When the temperature is above 1473 K (1200 °C), the metallization rate of carbon-containing pellets exceeds 93 pct, and the reduction reaction is substantially complete. Direct carburization is the main method for carburization of reduced iron. This reaction occurs above 1273 K (1000 °C), with carburization degree increasing greatly at 1473 K and 1573 K (1200 °C and 1300 °C) after particular holding times. Besides, to achieve the "slag (solid state) and iron (molten state) separation," the melting point of the slag phase should be increased. Slag (solid state) and iron (molten state) separation can be achieved below 1573 K (1300 °C), and when the holding time is 20 minutes, C/O is 0.7, basicity is less than 0.5 and a Na2CO3 level of 3 pct, the recovery rate of iron can reach 90 pct, with a proportion of iron nuggets more than 3.15 mm of nearly 90 pct. This study can provide theoretical and technical basis for iron nugget production.

  16. Effect of temperature on atom-atom collision chain length in metals

    International Nuclear Information System (INIS)

    Makarov, A.A.; Demkin, N.A.; Lyashchenko, B.G.

    1981-01-01

    Focused atom-atom collision chain lengths are calculated for fcc-crystals with account of thermal oscillations. The model of solid spheres with the Born-Merier potential has been used in the calculations. The dependence of chain lengths on the temperature, energy and movement direction of the first chain atom for Cu, Au, Ag, Pb, Ni is considered. The plot presented shows that the chain lengths strongly decrease with temperature growth, for example, for the gold at T=100 K the chain length equals up to 37 interatomic spacings, whereas at T=1000 K their length decreases down to 5 interatomic distances. The dependence of the energy loss by the chain atoms on the atom number in the chain is obtained in a wide range of crystal temperature and the primary chain atom energy [ru

  17. High-temperature steam-oxidation behavior of Zr-1Nb-1Sn-0.1Fe cladding tube at temperatures of 800-1000

    International Nuclear Information System (INIS)

    Lee, Cheol Min; Cho, Tae Won; Jeong, Gwan Yoon; Kim, Mi Jin; Kim, Ji Hyeon; Lee, Hee Jae; Sohn, Dong Seong; Mok, Yong Kyoon

    2016-01-01

    To prevent cladding failure, NRC issued a regulation Title 10 § 50.46, which specifies cladding temperature of 1204 .deg. C and 17% ECR should not be exceeded. The fundamental reason of the mechanical degradation of cladding is the formation of the oxide which is brittle. Theoretically, the oxide layer is formed following parabolic rate. However, from many experiments, sub-parabolic rates are often observed. There have been many suggestions so far; chemical and stress gradient across the oxide layer could initiate the sub-parabolic rate, the phase transformation of Zirconium dioxide from tetragonal to monoclinic could be the reason, change of the grain size of Zirconium dioxide could cause the cubic oxidation rate, and there is a suggestion that if electron migration is the major mechanism of the oxide growth, then the subparabolic rate can show up. However, the reason why the sub-parabolic rate appears is still not certain. Another important degradation mechanism is breakaway oxidation. A clear explanation that why the breakaway oxidation appears is still not clear. Most of the people believe the phase transformation of Zirconium dioxide cause instability within the oxide, which causes breakaway oxidation to appear. However, how much effect is caused from the phase transformation is not so sure. In this study, detailed analysis about the oxidation kinetics and the breakaway oxidation of Zr-1Nb-1Sn- 0.1Fe were carried out at temperatures between 800 - 1000 .deg. C.

  18. Phase diagram of Ti-B-C system in the temperature range of 300-3500 K

    International Nuclear Information System (INIS)

    Gusev, A.I.

    1996-01-01

    Calculation of phase equilibrium in the ternary system Ti-B-C in the areas of the TiC y -TiB 2 and B 4 C y -TiB 2 cross sections as well as partial construction of three-dimensional (spatial)diagram of the Ti-B-C system within the temperature range of 300-3500 K is carried out. The form of the isothermal cross section of the ternary system remains almost unchanged up to 1900 K. The most essential change is related to disordering of the low-temperature ordered phases Ti 2 C, Ti 3 C and Ti 6 C 5 of the titanium carbide at T > 950 K [ru

  19. Extreme Maximum Land Surface Temperatures.

    Science.gov (United States)

    Garratt, J. R.

    1992-09-01

    There are numerous reports in the literature of observations of land surface temperatures. Some of these, almost all made in situ, reveal maximum values in the 50°-70°C range, with a few, made in desert regions, near 80°C. Consideration of a simplified form of the surface energy balance equation, utilizing likely upper values of absorbed shortwave flux (1000 W m2) and screen air temperature (55°C), that surface temperatures in the vicinity of 90°-100°C may occur for dry, darkish soils of low thermal conductivity (0.1-0.2 W m1 K1). Numerical simulations confirm this and suggest that temperature gradients in the first few centimeters of soil may reach 0.5°-1°C mm1 under these extreme conditions. The study bears upon the intrinsic interest of identifying extreme maximum temperatures and yields interesting information regarding the comfort zone of animals (including man).

  20. Performance evaluation of a lossy transmission lines based diode detector at cryogenic temperature.

    Science.gov (United States)

    Villa, E; Aja, B; de la Fuente, L; Artal, E

    2016-01-01

    This work is focused on the design, fabrication, and performance analysis of a square-law Schottky diode detector based on lossy transmission lines working under cryogenic temperature (15 K). The design analysis of a microwave detector, based on a planar gallium-arsenide low effective Schottky barrier height diode, is reported, which is aimed for achieving large input return loss as well as flat sensitivity versus frequency. The designed circuit demonstrates good sensitivity, as well as a good return loss in a wide bandwidth at Ka-band, at both room (300 K) and cryogenic (15 K) temperatures. A good sensitivity of 1000 mV/mW and input return loss better than 12 dB have been achieved when it works as a zero-bias Schottky diode detector at room temperature, increasing the sensitivity up to a minimum of 2200 mV/mW, with the need of a DC bias current, at cryogenic temperature.

  1. ACT-1000. Group activation cross-section library for WWER-1000 type reactors

    Energy Technology Data Exchange (ETDEWEB)

    Zolotarev, K I; Pashchenko, A B [National Research Centre - A.I. Leipunsky Institute for Physics and Power Engineering, Obninsk (Russian Federation)

    2001-10-01

    The ACT-1000, a problem-oriented library of group-averaged activation cross-sections for WWER-1000 type reactors, is based on evaluated microscopic cross-section data files. The ACT-1000 data library was designed for calculating induced activity for the main dose-generated nuclides contained in WWER-1000 structural materials. In preparing the ACT-1000 library, 47 group-averaged cross-section data for the 10{sup -9}-17.33 MeV energy range were used to calculate the spatial-energy neutron flux distribution. (author)

  2. Fault of the correction factor for pressure and temperature kPT in the atmospheric conditions of Dosimetric Calibration Lab. - LSCD of ININ - Mexico

    International Nuclear Information System (INIS)

    Alvarez R, Jose T.; Jesus Cejudo, A.; La Cruz H., Daniel de; Tovar M, Victor M.

    2013-01-01

    The realization of the operational quantities H*, Hp y/0 H'(0.07) for estimating the effective dose E, usually is done by measuring the air kerma Ka air within the field of ionizing radiation of interest and was subsequently applied appropriate conversion factors for both the quality of radiation and the operational quantity of interest. However, the SSDL in performing the Ka to environmental conditions of ININ (3000 m above sea level, P ∼ 710 hPa) with ionization chambers has found that the pressure correction factor and kPT temperature is not sufficient to correct the change in air density. Indeed, in the case of 60 Co the discrepancy between the measurement of a primary standard graphite walls Ka (BEV CC01 be 131) and a side of the plastic walls (Exradin A12) is on the order of 0.4% for the case of the RX BIPM qualities to 100,135, 180 and 250 kV. It was found that for a camera model 30001 PTW (PMMA graphite wall) is needed an additional correction factor k PT ranging from 0.4% to 1.5%, correction factor calculated by MC simulation. For Sk of 125 I brachytherapy sources was given an additional correction lower in 11% compared to conventional k PT value measured with a well chamber Standard Imaging HDR 1000 plus. Finally, it is in the process of studying the behavior of this additional correction factor to the case of 137 Cs

  3. PdMn and PdFe: New Materials for Temperature Measurement Near 2K

    International Nuclear Information System (INIS)

    Adriaans, M.J.; Aselage, T.L.; Day, P.K.; Duncan, R.V.; Klemme, B.J.; Sergatskov, D.A.

    1999-01-01

    Interest in the critical dynamics of superfluid 4 He in microgravity conditions has motivated the development of new high resolution thermometry technol- ogy for use in space experiments near 2K. The current material commonly used as the temperature sensing element for high resolution thermometers (HRTs) is copper ammonium bromide [Cu(NH 4 ) 2 Br 4 2H 2 0) or ''CAB'', which undergoes a ferromagnetic phase transition at 1.8K1. HRTs made from CAB have demonstrated low drift ( -13 K/s

  4. Influences of spark plasma sintering temperature on the microstructures and thermoelectric properties of (Sr0.95Gd0.05)TiO3 ceramics

    Science.gov (United States)

    Li, Liang-Liang; Qin, Xiao-Ying; Liu, Yong-Fei; Liu, Quan-Zhen

    2015-06-01

    (Sr0.95Gd0.05)TiO3 (SGTO) ceramics are successfully prepared via spark plasma sintering (SPS) respectively at 1548, 1648, and 1748 K by using submicron-sized SGTO powders synthesized from a sol-gel method. The densities, microstructures, and thermoelectric properties of the SGTO ceramics are studied. Though the Seebeck coefficient shows no obvious difference in the case that SPS temperatures range from 1548 K to 1648 K, the electrical conductivity and the thermal conductivity increase remarkably due to the increase in grain size and density. The sample has a density higher than 98% theoretical density as the sintering temperature increases up to 1648 K and shows average grain sizes increasing from ˜ 0.7 μm to 7 μm until 1748 K. As a result, the maximum of the dimensionless figure of merit of ˜ 0.24 is achieved at ˜ 1000 K for the samples sintered at 1648 K and 1748 K, which was ˜ 71% larger than that (0.14 at ˜ 1000 K) for the sample sintered at 1548 K due to the enhancement of the power factor. Project supported by the National Natural Science Foundation of China (Grant Nos. 11174292, 51101150, and 11374306).

  5. Dislocation mechanisms for plastic flow of nickel in the temperature range 4.2-1200K

    International Nuclear Information System (INIS)

    Sastry, D.H.; Tangri, K.

    1975-01-01

    The temperature ranges of thermal and athermal deformation behaviour of nickel are identified by employing the temperature-dependence of flow-stress and strain-rate cycling data. The results are used to present a unified view of dislocation mechanisms of glide encompassing the two thermally activated and the intermediate athermal regimes of plastic flow. In the low-temperature thermally activated region (<250K) the strain rate is found to be controlled by the repulsive intersection of glide and forest dislocations, in accordance with current ideas. The athermal stress in this region can be attributed mainly to the presence of strong attractive junctions which are overcome by means of Orowan bowing, a small contribution also coming from the elastic interactions between dislocations. The values of activation area and activation energy obtained in the high-temperature region (<750K) negate the operation of a diffusion-controlled mechanism. Instead, the data support a thermal activation model involving unzipping of the attractive junctions. The internal (long-range) stress contribution here results solely from the elastic interactions between dislocations. This view concerning the high-temperature plastic flow is further supported by the observation that the Cottrell-Stokes law is obeyed over large strains in the range 750-1200K. (author)

  6. 1000 MW steam turbine for nuclear power station

    International Nuclear Information System (INIS)

    Drahy, J.

    1987-01-01

    Skoda Works started the manufacture of the 1000 MW steam turbine for the Temelin nuclear power plant. The turbine will use saturated steam at 3,000 r.p.m. It will allow steam supply to heat water for district heating, this of an output of 893 MW for a three-stage water heating at a temperature of 150/60 degC or of 570 MW for a two-stage heating at a temperature of 120/60 degC. The turbine features one high-pressure and three identical low-pressure stages. The pressure gradient between the high-pressure and the low-pressure parts was optimized as concerns the thermal efficiency of the cycle and the thermodynamic efficiency of the low-pressure part. A value of 0.79 MPa was selected corresponding to the maximum flow rate of the steam entering the turbine. This is 5,495 t/h, the admission steam parameters are 273.3 degC and 5.8 MPa. The feed water temperature is 220.9 degC. It is expected that throughout the life of the turbine, there will be 300 cold starts, 1,000 starts following shutdown for 55 to 88 hours, and 600 starts following shutdown for 8 hours. (Z.M.). 8 figs., 1 ref

  7. Meteorologická pozorování Alexandra Zawadzkého v Brně v letech 1861-1867

    Czech Academy of Sciences Publication Activity Database

    Brázdil, Rudolf; Řezníčková, Ladislava; Valášek, H.

    2013-01-01

    Roč. 118, č. 4 (2013), s. 334-355 ISSN 1212-0014 R&D Projects: GA ČR GA13-19831S Institutional support: RVO:67179843 Keywords : meteorological observation * air pressure * air temperature * precipitation * wind * atmospheric phenomena * Alexander Zawadzki * Pavel Olexík * Brno Subject RIV: DG - Athmosphere Sciences, Meteorology Impact factor: 0.400, year: 2013 http://geography.cz/sbornik/wp-content/uploads/downloads/2013/12/g13-4-s334-355-br%C3%A1zdil.pdf

  8. Evaluation of water cooled supersonic temperature and pressure probes for application to 1366 K flows

    Science.gov (United States)

    Lagen, Nicholas; Seiner, John M.

    1990-01-01

    Water cooled supersonic probes are developed to investigate total pressure, static pressure, and total temperature in high-temperature jet plumes and thereby determine the mean flow properties. Two probe concepts, designed for operation at up to 1366 K in a Mach 2 flow, are tested on a water cooled nozzle. The two probe designs - the unsymmetric four-tube cooling configuration and the symmetric annular cooling design - take measurements at 755, 1089, and 1366 K of the three parameters. The cooled total and static pressure readings are found to agree with previous test results with uncooled configurations. The total-temperature probe, however, is affected by the introduction of water coolant, and effect which is explained by the increased heat transfer across the thermocouple-bead surface. Further investigation of the effect of coolant on the temperature probe is proposed to mitigate the effect and calculate more accurate temperatures in jet plumes.

  9. Thermodynamic properties of deep eutectic solvent and ionic liquid mixtures at temperatures from 293.15 K to 343.15 K

    Science.gov (United States)

    Achsah, R. S.; Shyam, S.; Mayuri, N.; Anantharaj, R.

    2018-04-01

    Deep eutectic solvents (DES) and ionic liquids (ILs) have their applications in various fields of research and in industries due to their attractive physiochemical properties. In this study, the combined thermodynamic properties of DES (choline chloride-glycerol) + IL1 (1-butyl-3-methylimiazolium acetate) and DES(choline chloride-glycerol) + IL2 (1-ethyl-3-methylimadzolium ethyl sulphate) have been studied. The thermodynamic properties such as excess molar volume, partial molar volume, excess partial molar volume and apparent molar volume were calculated for different mole fractions ranging from 0 to 1 and varying temperatures from 293.15 K to 343.15 K. In order to know the solvent properties of DESs and ILs mixtures at different temperatures and their molecular interactions to enhance the solvent performance and process efficiency at fixed composition and temperature the thermodynamic properties were analyzed.

  10. Temperature dependence on shock response of stainless steel

    International Nuclear Information System (INIS)

    Gu Zhuowei; Jin Xiaogang

    1998-01-01

    Free surface velocity measurements were reported for HR-2(Cr-Ni-Mn-N) stainless steel, initially heated to 300K∼1000K and shock-compressed to about 8GPa. The corresponding spall strength σ f and Hugoniot elastic limit σ HEL were determined from the wave profiles. It is demonstrated that σ f and σ HEL decrease linearly with increasing temperature T in the range from 300K to 806K, i.e., σ f =5.63-4.32x10 -3 T and σ HEL =2.08-1.54x10 -3 T, and in the range of 806K∼980K, σ HEL increases from 0.84GPa at 806K to 0.93GPa at 980K, σ f has a negligible increase to 2.15GPa from 2.14GPa. Primary TEM test on recovery samples identified the existence of intermatallic compound Ni 3 Ti in the sample of 980K

  11. Laser parameters of a Fe : ZnSe crystal in the 85-255-K temperature range

    NARCIS (Netherlands)

    Voronov, AA; Kozlovskii, [No Value; Korostelin, YV; Podmar'kov, YP; Frolov, MP

    The temperature dependence of the efficiency of a laser based on a Fe:ZnSe crystal grown from the vapour phase by the free-growth method is studied in the 85-255-K temperature range. As the temperature was increased, the slope efficiency of the laser with respect to absorbed energy decreased from

  12. ASTEC and MELCOR comparison for a VVER-1000 60 mm small break LOCA

    International Nuclear Information System (INIS)

    Georgieva, J.; Stefanova, A.; Groudev, P.; Tusheva, P.; Mladenov, I.; Dimov, D.; Passalacqua, R.

    2005-01-01

    In this paper a comparison between severe accident calculations performed for a WWER 1000 with the ASTEC1.1v0 and MELCOR 1.8.5 computer codes for a small break LOCA (ID 60 mm) without intervention of hydro accumulators is presented. This investigation has been performed in the framework of the SARNET project under the EURATOM 6th framework program. Once the accident sequence scenario is specified, both codes (MELCORE and ASTEC) are able to determine the core and containment damaged states, to estimate the release of radionuclides from the fuel as well as from the primary circuit and containment. Theses results are used to estimate the maximum period of the time during which the personnel could still take particular decisions in order to mitigate such an accident. The aim of the performed analysis is to estimate the discrepancy between ASTEC and MELCORE 1.8.5 calculations. Such discrepancies will be studied, if the case, proposal for ASTEC improvements will be made. Also the ASTEC capability to simulate specific reactor accident scenarios and/or particular safety systems will be tested. The final target is to propose severe accident management procedure for WWER 1000 reactors. In conclusions, the analysis for a small break LOCA (ID 60 mm without hydroelectricities) has shown some discrepancies between ASTEC and MELCORE especially during the degradation of the core. Further analyses are planed in which the MELCORE temperature 'set point' for core degradation (2520 K) will be progressively increased to approach the ASTEC one (which has been estimated to be about 3200 K). The comparison of the new results will allow a better evaluation of the in-vessel models implemented in ASTEC

  13. CaMn(1-x)Nb(x)O3 (x < or = 0.08) perovskite-type phases as promising new high-temperature n-type thermoelectric materials.

    Science.gov (United States)

    Bocher, L; Aguirre, M H; Logvinovich, D; Shkabko, A; Robert, R; Trottmann, M; Weidenkaff, A

    2008-09-15

    Perovskite-type CaMn(1-x)Nb(x)O(3+/-delta) (x = 0.02, 0.05, and 0.08) compounds were synthesized by applying both a "chimie douce" (SC) synthesis and a classical solid state reaction (SSR) method. The crystallographic parameters of the resulting phases were determined from X-ray, electron, and neutron diffraction data. The manganese oxidations states (Mn(4+)/Mn(3+)) were investigated by X-ray photoemission spectroscopy. The orthorhombic CaMn(1-x)Nb(x)O(3+/-delta) (x = 0.02, 0.05, and 0.08) phases were studied in terms of their high-temperature thermoelectric properties (Seebeck coefficient, electrical resistivity, and thermal conductivity). Differences in electrical transport and thermal properties can be correlated with different microstructures obtained by the two synthesis methods. In the high-temperature range, the electron-doped manganate phases exhibit large absolute Seebeck coefficient and low electrical resistivity values, resulting in a high power factor, PF (e.g., for x = 0.05, S(1000K) = -180 microV K(-1), rho(1000K) = 16.8 mohms cm, and PF > 1.90 x 10(-4) W m(-1) K(-2) for 450 K 0.3) make these phases the best perovskitic candidates as n-type polycrystalline thermoelectric materials operating in air at high temperatures.

  14. Depth Dependent Relationships between Temperature and Ocean Heterotrophic Prokaryotic Production

    KAUST Repository

    Lønborg, Christian

    2016-06-07

    Marine prokaryotes play a key role in cycling of organic matter and nutrients in the ocean. Using a unique dataset (>14,500 samples), we applied a space-for-time substitution analysis to assess the temperature dependence of prokaryotic heterotrophic production (PHP) in epi- (0-200 m), meso- (201-1000 m) and bathypelagic waters (1001-4000 m) of the global ocean. Here, we show that the temperature dependence of PHP is fundamentally different between these major oceanic depth layers, with an estimated ecosystem-level activation energy (E) of 36 ± 7 kJ mol for the epipelagic, 72 ± 15 kJ mol for the mesopelagic and 274 ± 65 kJ mol for the bathypelagic realm. We suggest that the increasing temperature dependence with depth is related to the parallel vertical gradient in the proportion of recalcitrant organic compounds. These Ea predict an increased PHP of about 5, 12, and 55% in the epi-, meso-, and bathypelagic ocean, respectively, in response to a water temperature increase by 1°C. Hence, there is indication that a major thus far underestimated feedback mechanism exists between future bathypelagic ocean warming and heterotrophic prokaryotic activity.

  15. Depth Dependent Relationships between Temperature and Ocean Heterotrophic Prokaryotic Production

    KAUST Repository

    Lø nborg, Christian; Cuevas, L. Antonio; Reinthaler, Thomas; Herndl, Gerhard J.; Gasol, Josep M.; Moran, Xose Anxelu G.; Bates, Nicholas R.; á lvarez-Salgado, Xosé A.

    2016-01-01

    Marine prokaryotes play a key role in cycling of organic matter and nutrients in the ocean. Using a unique dataset (>14,500 samples), we applied a space-for-time substitution analysis to assess the temperature dependence of prokaryotic heterotrophic production (PHP) in epi- (0-200 m), meso- (201-1000 m) and bathypelagic waters (1001-4000 m) of the global ocean. Here, we show that the temperature dependence of PHP is fundamentally different between these major oceanic depth layers, with an estimated ecosystem-level activation energy (E) of 36 ± 7 kJ mol for the epipelagic, 72 ± 15 kJ mol for the mesopelagic and 274 ± 65 kJ mol for the bathypelagic realm. We suggest that the increasing temperature dependence with depth is related to the parallel vertical gradient in the proportion of recalcitrant organic compounds. These Ea predict an increased PHP of about 5, 12, and 55% in the epi-, meso-, and bathypelagic ocean, respectively, in response to a water temperature increase by 1°C. Hence, there is indication that a major thus far underestimated feedback mechanism exists between future bathypelagic ocean warming and heterotrophic prokaryotic activity.

  16. Simulation of advanced accumulator and its application in CPR1000 LBLOCA analysis

    International Nuclear Information System (INIS)

    Hu, Hongwei; Shan, Jianqiang; Gou, Junli; Cao, Jianhua; Shen, Yonggang; Fu, Xiangang

    2014-01-01

    Highlights: • The analysis model was developed for advanced accumulator. • The sensitivity analysis of each key parameter was performed. • The LBLOCA was analyzed for the CPR1000 with advanced accumulator. • The analysis shows that advanced accumulator can improve CPR1000 safety performance. - Abstract: The advanced accumulator is designed to improve the safety and reliability of CPR1000 by providing a small injection flow to keep the reactor core in flooded condition. Thus, the core still stays in a cooling state without the intervention of low pressure safety injection and the startup grace time of the low pressure safety injection pump can be greatly extended. A new model for the advanced accumulator, which is based on the basic conservation equations, is developed and incorporated into RELAP5/MOD 3.3. The simulation of the advanced accumulator can be carried out and results show that the behavior of the advanced accumulator satisfied its primary design target. There is a large flow in the advanced accumulator at the initial stage. When the accumulator water level is lower than the stand pipe, a vortex appears in the damper, which results in a large pressure drop and a small flow. And then the sensitivity analysis is performed and the major factors which affected the flow rate of the advanced accumulator were obtained, including the damper diameter, the initial volume ratio of the water and the nitrogen and the diameter ratio of the standpipe and the small pipe. Additionally, the primary coolant loop cold leg double-ended guillotine break LBLOCA in CPR1000 with advanced accumulator is analyzed. The results show that the criterion for maximum cladding temperature limit (1477 K) (NRC, 1992) can be met ever with 200 s after the startup of the low pressure safety injection. From this point of view, passive advanced accumulator can strive a longer grace time for LPSI. Thus the reliability, safety and economy of the reactor system can be improved

  17. Research on the hot deformation behavior of a Fe-Ni-Cr alloy (800H) at temperatures above 1000 °C

    Science.gov (United States)

    Cao, Yu; Di, Hongshuang

    2015-10-01

    Considering the pinning effect of fine carbides on grain boundaries, hot compression tests were performed above the dissolution temperature of Cr23C6 to investigate the hot deformation behavior of a Fe-Ni-Cr alloy (800H). The results show that the single peak stress associated with dynamic recrystalization (DRX) became more distinct at higher temperature and lower strain rate. The process of DRX was thoroughly stimulated when deformed above 1000 °C. Constitutive equations for hot deformation were established by regression analysis of conventional hyperbolic sine equation. The relationships between Zener-Hollomon parameter (Z) and the characteristic points of flow curves were established using the power law relation. Furthermore, kernel average misorientation (KAM) and grain orientation spread (GOS) were used to map the distribution of local misorientation and estimate the fraction of DRX, respectively. The critical strain and peak strain were used to predict the kinetics of DRX with the Avrami-type equation.

  18. Air oxidation of Zircaloy-4 in the 600-1000 °C temperature range: Modeling for ASTEC code application

    Science.gov (United States)

    Coindreau, O.; Duriez, C.; Ederli, S.

    2010-10-01

    Progress in the treatment of air oxidation of zirconium in severe accident (SA) codes are required for a reliable analysis of severe accidents involving air ingress. Air oxidation of zirconium can actually lead to accelerated core degradation and increased fission product release, especially for the highly-radiotoxic ruthenium. This paper presents a model to simulate air oxidation kinetics of Zircaloy-4 in the 600-1000 °C temperature range. It is based on available experimental data, including separate-effect experiments performed at IRSN and at Forschungszentrum Karlsruhe. The kinetic transition, named "breakaway", from a diffusion-controlled regime to an accelerated oxidation is taken into account in the modeling via a critical mass gain parameter. The progressive propagation of the locally initiated breakaway is modeled by a linear increase in oxidation rate with time. Finally, when breakaway propagation is completed, the oxidation rate stabilizes and the kinetics is modeled by a linear law. This new modeling is integrated in the severe accident code ASTEC, jointly developed by IRSN and GRS. Model predictions and experimental data from thermogravimetric results show good agreement for different air flow rates and for slow temperature transient conditions.

  19. Oxidation characteristics of Ti-14Al-21Nb alloy at high temperature in purified oxygen; Ti-14Al?-21Nb gokin no sansochu ni okeru koon sanka tokusei

    Energy Technology Data Exchange (ETDEWEB)

    Akai, M; Taniguchi, S; Shibata, T [Osaka University, Osaka (Japan). Faculty of Engineering

    1994-10-20

    The Ti-14Al-21Nb alloy called Super {alpha}{sub 2} is an alloy which has been improved of plastic transformation ability by adding Nb into Ti3Al with high specific strength, and is used for member materials in aircraft engines. In order to identify its oxidation characteristics, this paper discusses the oxidation characteristics under purified oxygen and atmospheric pressure in temperatures ranging from 1000 K to 1300 K. The experiment made a button-formed ingot with a diameter of 50 mm and a thickness of about 10 mm by melting and thermal refining, and used a thermobalance. Main conclusion thus obtained may be summarized as follows: the amount of increase due to oxidation after 100 ks oxidation at 1000 K is very small; oxidation between 1100 K and 1200 K follows nearly the parabolic rate laws; the scale consisted mainly of rutile, but a thin alumina concentration layer is formed; Nb is concentrated in the rutile-alumina mixed layer, and local fracture and regeneration are repeated at temperatures higher than 1300 K. 21 refs., 8 figs., 2 tabs.

  20. Facile synthesis of high-temperature (1000 °C) phase-stable rice-like anatase TiO{sub 2} nanocrystals

    Energy Technology Data Exchange (ETDEWEB)

    Lv, Lizhen [Capital Normal University, Beijing Key Laboratory for Optical Materials and Photonic Devices, Department of Chemistry (China); Chen, Qirong [Beijing Center for Physical and Chemical Analysis (BCPCA) (China); Liu, Xiuyun; Wang, Miaomiao; Meng, Xiangfu, E-mail: xfmeng@cnu.edu.cn [Capital Normal University, Beijing Key Laboratory for Optical Materials and Photonic Devices, Department of Chemistry (China)

    2015-05-15

    High-temperature phase-stable rice-like anatase TiO{sub 2} nanocrystals were synthesized by one-pot solvothermal method using soluble titania xerogel and isopropyl alcohol (IPA) as the precursor and the solvent, respectively. Sample characterization was carried out by powder X-ray diffraction, high-resolution transmission electron microscopy, field emission scanning electron microscope, X-ray photoelectron spectroscopy, and N{sub 2} adsorption–desorption isotherms. The results showed that TiO{sub 2} nanocrystals had rice-like shapes with an average size of 5 nm in width and 35 nm in length. The BET surface area was 153 m{sup 2}/g. Unexpectedly, the rice-like TiO{sub 2} nanocrystals exhibited high-temperature phase stability, which could remain as pure anatase phase after calcinations at 1000 °C. Growth mechanism investigation revealed that the IPA solvent played a key role in nucleation and growth of rice-like anatase TiO{sub 2} nanocrystals. The photodegradation of rhodamine B demonstrated that rice-like anatase TiO{sub 2} nanocrystals exhibited enhanced photocatalytic activity under visible light irradiation.

  1. Thermal stability and high temperature polymorphism of topochemically-prepared Dion–Jacobson triple-layered perovskites

    Energy Technology Data Exchange (ETDEWEB)

    Guertin, Stephen L.; Josepha, Elisha A.; Montasserasadi, Dariush; Wiley, John B., E-mail: jwiley@uno.edu

    2015-10-25

    The thermal stability of six Dion–Jacobson-related triple layered perovskites, ACa{sub 2}Nb{sub 3}O{sub 10} (A = H, NH{sub 4}, Li, Na, K, CuCl), was explored to 1000 °C. Each compound was produced topochemically by low-temperature (<500 °C) ion exchange from RbCa{sub 2}Nb{sub 3}O{sub 10}. The thermal behavior of the series was examined by variable temperature X-ray powder diffraction experiments in tandem with thermogravimetric analysis and differential scanning calorimetry. Five of the species were found to be low temperature/metastable phases, decomposing below 900 °C, where the stability of the series decreased with decreasing interlayer cation size. The compounds, A = Li, Na, K, exhibited high temperature polymorphism, with a completely reversible transition evident for KCa{sub 2}Nb{sub 3}O{sub 10}. - Highlights: • Thermal stability of topochemically prepared triple-layered perovskites studied. • Clear correlation seen between stability and identity of interlayer cation. • Several in ACa{sub 2}Nb{sub 3}O{sub 10} series (A = Li, Na, K) exhibit high temperature polymorphism.

  2. Posttest examination of the VVER-1000 fuel rod bundle CORA-W2

    International Nuclear Information System (INIS)

    Sepold, L.

    1995-06-01

    The bundle meltdown experiment CORA-W2, representing the behavior of a Russian type VVER-1000 fuel element, with one B 4 C/stainless steel absorber rod was selected by the OECD/CSNI as International Standard Problem (ISP-36). The experimental results of CORA-W2 serve as data base for comparison with analytical predictions of the high-temperature material behavior by various code systems. The first part of the experimental results is described in KfK 5363 (1994), the second part is documented in this report which contains the destructive post-test examination results. The metallographical and analytical (SEM/EDX) post-test examinations were performed in Germany and Russia and are summarized in five individual contributions. The upper half of the bundle is completely oxidized, the lower half has kept the fuel rods relatively intact. The post-test examination results show the strong impact of the B 4 C absorber rod and the stainless steel grid spacers on the ''low-temperature'' bundle damage initiation and progression. The B 4 C absorber rod completely disappeared in the upper half of the bundle. The multicomponent melts relocated and formed coolant channel blockages on solidification with a maximum extent of about 30% in the lower part of the bundle. At temperatures above the melting point of the ZrNb1 cladding extensive fuel dissolution occurred. (orig.) [de

  3. Isobaric specific heat capacity of water and aqueous cesium chloride solutions for temperatures between 298 K and 370 K at p = 0.1 MPa

    International Nuclear Information System (INIS)

    Lourenco, M.J.V.; Santos, F.J.V.; Ramires, M.L.V.; Nieto de Castro, C.A.

    2006-01-01

    There has been some controversy regarding the uncertainty of measurements of thermal properties using differential scanning calorimeters, namely heat capacity of liquids. A differential scanning calorimeter calibrated in enthalpy and temperature was used to measure the isobaric specific heat capacity of water and aqueous solutions of cesium chloride, in the temperature range 298 K to 370 K, for molalities up 3.2 mol . kg -1 , at p = 0.1 MPa, with an estimated uncertainty (ISO definition) better than 1.1%, at a 95% confidence level. The measurements are completely traceable to SI units of energy and temperature. The results obtained were correlated as a function of temperature and molality and compared with other authors, obtained by different methods and permit to conclude that a DSC calibrated by Joule effect is capable of very accurate measurements of the isobaric heat capacity of liquids, traceable to SI units of measurement

  4. Electric resistance of nickel and niobium in the temperature range of 300-1300 K

    International Nuclear Information System (INIS)

    Novikov, I.I.; Roshchupkin, V.V.; Mozgovoj, A.G.; Semashko, N.A.

    1982-01-01

    The results of experimental investigation of nickel and niobium electric resistance on the wire samples by the potentiometric method in the temperature range of 300-1300 K are presented. Experimental data processing by the least square method is carried out; approximating equations of temperature dependence of the nickel and niobium electric resistance are prepared

  5. Multidimensional modeling of the effect of fuel injection pressure on temperature distribution in cylinder of a turbocharged DI diesel engine

    Directory of Open Access Journals (Sweden)

    Sajjad Emami

    2013-06-01

    Full Text Available In this study, maintaining a constant fuel rate, injection pressure of 275 bar to 1000 bar (275×102 kPa to 1000×102 kPa, has been changed. Effect of injection pressure, the pressure inside the cylinder on the free energy, power, engine indicators, particularly indicators of fuel consumption, pollutants and their effects on parameters affecting the output of the engine combustion chamber have been studied in droplet diameter. Finally, the effects of fuel mixture equivalence, Cantor temperature, soot and NOx due to the increase of injection pressure, engine efficiency and emissions have been examined.

  6. Comparison of thermal properties of fish collagen and bovine collagen in the temperature range 298-670K.

    Science.gov (United States)

    Gauza-Włodarczyk, Marlena; Kubisz, Leszek; Mielcarek, Sławomir; Włodarczyk, Dariusz

    2017-11-01

    The increased interest in fish collagen is a consequence of the risk of exposure to Creutzfeld-Jacob disease (CJD) and the bovine spongiform encephalopathy (BSE), whose occurrence is associated with prions carried by bovine collagen. Collagen is the main biopolymer in living organisms and the main component of the skin and bones. Until the discovery of the BSE, bovine collagen had been widely used. The BSE epidemic increased the interest in new sources of collagen such as fish skin collagen (FSC) and its properties. Although the thermal properties of collagen originating from mammals have been well described, less attention has been paid to the thermal properties of FSC. Denaturation temperature is a particularly important parameter, depending on the collagen origin and hydration level. In the reported experiment, the free water and bound water release processes along with thermal denaturation process were studied by means of the differential scanning calorimetry (DSC). Measurements were carried out using a DSC 7 instrument (Elmer-Perkin), in the temperature range 298-670K. The study material was FSC derived by acidic hydration method. The bovine Achilles tendon (BAT) collagen type I was used as the control material. The thermograms recorded revealed both, exothermic and endothermic peaks. For both materials, the peaks in the temperature range of 330-360K were assigned to the release of free water and bound water. The denaturation temperatures of FSC and BAT collagen were determined as 420K and 493K, respectively. Thermal decomposition process was observed at about 500K for FSC and at about 510K for BAT collagen. These results show that FSC is less resistant to high temperature than BAT collagen. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Magic angle spinning NMR below 6 K with a computational fluid dynamics analysis of fluid flow and temperature gradients

    Science.gov (United States)

    Sesti, Erika L.; Alaniva, Nicholas; Rand, Peter W.; Choi, Eric J.; Albert, Brice J.; Saliba, Edward P.; Scott, Faith J.; Barnes, Alexander B.

    2018-01-01

    We report magic angle spinning (MAS) up to 8.5 kHz with a sample temperature below 6 K using liquid helium as a variable temperature fluid. Cross polarization 13C NMR spectra exhibit exquisite sensitivity with a single transient. Remarkably, 1H saturation recovery experiments show a 1H T1 of 21 s with MAS below 6 K in the presence of trityl radicals in a glassy matrix. Leveraging the thermal spin polarization available at 4.2 K versus 298 K should result in 71 times higher signal intensity. Taking the 1H longitudinal relaxation into account, signal averaging times are therefore predicted to be expedited by a factor of >500. Computer assisted design (CAD) and finite element analysis were employed in both the design and diagnostic stages of this cryogenic MAS technology development. Computational fluid dynamics (CFD) models describing temperature gradients and fluid flow are presented. The CFD models bearing and drive gas maintained at 100 K, while a colder helium variable temperature fluid stream cools the center of a zirconia rotor. Results from the CFD were used to optimize the helium exhaust path and determine the sample temperature. This novel cryogenic experimental platform will be integrated with pulsed dynamic nuclear polarization and electron decoupling to interrogate biomolecular structure within intact human cells.

  8. Analysis of an accident type sbloca in reactor contention AP1000 with 8.0 Gothic code; Analisis de un accidente tipo Sbloca en la contencion del reactor AP1000 con el codigo Gothic 8.0

    Energy Technology Data Exchange (ETDEWEB)

    Goni, Z.; Jimenez Varas, G.; Fernandez, K.; Queral, C.; Montero, J.

    2016-08-01

    The analysis is based on the simulation of a Small Break Loss-of-Coolant-Accident in the AP1000 nuclear reactor using a Gothic 8.0 tri dimensional model created in the Science and Technology Group of Nuclear Fision Advanced Systems of the UPM. The SBLOCA has been simulated with TRACE 5.0 code. The main purpose of this work is the study of the thermo-hydraulic behaviour of the AP1000 containment during a SBLOCA. The transients simulated reveal close results to the realistic behaviour in case of an accident with similar characteristics. The pressure and temperature evolution enables the identification of the accident phases from the RCS point of view. Compared to the licensing calculations included in the AP1000 Safety Analysis, it has been proved that the average pressure and temperature evolution is similar, yet lower than the licensing calculations. However, the temperature and inventory distribution are significantly heterogeneous. (Author)

  9. Interaction between Na+/K+-pump and Na+/Ca2+-exchanger modulates intercellular communication.

    Science.gov (United States)

    Matchkov, Vladimir V; Gustafsson, Helena; Rahman, Awahan; Briggs Boedtkjer, Donna M; Gorintin, Sarah; Hansen, Anne Kirstine; Bouzinova, Elena V; Praetorius, Helle A; Aalkjaer, Christian; Nilsson, Holger

    2007-04-13

    Ouabain, a specific inhibitor of the Na(+)/K(+)-pump, has previously been shown to interfere with intercellular communication. Here we test the hypothesis that the communication between vascular smooth muscle cells is regulated through an interaction between the Na(+)/K(+)-pump and the Na(+)/Ca(2+)-exchanger leading to an increase in the intracellular calcium concentration ([Ca(2+)](i)) in discrete areas near the plasma membrane. [Ca(2+)](i) in smooth muscle cells was imaged in cultured rat aortic smooth muscle cell pairs (A7r5) and in rat mesenteric small artery segments simultaneously with force. In A7r5 coupling between cells was estimated by measuring membrane capacitance. Smooth muscle cells were uncoupled when the Na(+)/K(+)-pump was inhibited either by a low concentration of ouabain, which also caused a localized increase of [Ca(2+)](i) near the membrane, or by ATP depletion. Reduction of Na(+)/K(+)-pump activity by removal of extracellular potassium ([K(+)](o)) also uncoupled cells, but only after inhibition of K(ATP) channels. Inhibition of the Na(+)/Ca(2+)-exchange activity by SEA0400 or by a reduction of the equilibrium potential (making it more negative) also uncoupled the cells. Depletion of intracellular Na(+) and clamping of [Ca(2+)](i) at low concentrations prevented the uncoupling. The experiments suggest that the Na(+)/K(+)-pump may affect gap junction conductivity via localized changes in [Ca(2+)](i) through modulation of Na(+)/Ca(2+)-exchanger activity.

  10. Mechanical properties of polymer matrix composites at 77 K and at room temperature after irradiation with 60Co γ-rays

    International Nuclear Information System (INIS)

    Egusa, S.; Hagiwara, M.

    1986-01-01

    Ten different polymer matrix composites were irradiated with 60 Co γ-rays at room temperature, and were examined with regard to the mechanical properties at 77 K and at room temperature. The radiation resistance of these composites depends primarily on the radiation resistance of matrix resins, which increases in the order diglycidyl ether of bisphenol A < tetraglycidyl diaminodiphenyl methane < Kerimid 601. Comparison of the mechanical properties tested at 77 K and at room temperature demonstrates that the extent of radiation-induced decrease in the composite strength is appreciably greater in the 77 K test than in the room temperature test. (author)

  11. Pyroelectric Properties of Potassium and Rubidium Titanyl-Arsenate Single Crystals in the Temperature Range of 4.2-300 K

    International Nuclear Information System (INIS)

    Shaldin, Yu. V.; Matyjasik, S.; Novikova, N. E.; Tseitlin, M.; Mozhaev, E.; Roth, M.

    2010-01-01

    The temperature dependences of the pyroelectric coefficients of KTiOAsO 4 and RbTiOAsO 4 single crystals grown by flux crystallization have been investigated in the temperature range of 4.2-300 K. With an increase in temperature, superionic conductivity first arises in KTiOAsO4 (at T > 200 K) and then (at T > 270 K) in RbTiOAsO 4 . This conductivity is much higher in the samples polarized at T = 4.2 K. An exponential change in the crystal resistivity along the polar direction is simultaneously observed. The results of measurements in the range of 4.2-200 K indicate larger values of pyroelectric coefficients when compared with potassium and rubidium titanyl-phosphate crystals. A correlation between the pyroelectric coefficients and a change in the lattice constants at isomorphic substitutions of K atoms for Rb and P atoms for As has been revealed within the symmetry approach.

  12. Pyroelectric Properties of Potassium and Rubidium Titanyl-Arsenate Single Crystals in the Temperature Range of 4.2-300 K

    Energy Technology Data Exchange (ETDEWEB)

    Shaldin, Yu. V., E-mail: yuri1999@rambler.ru [Russian Academy of Sciences, Shubnikov Institute of Crystallography (Russian Federation); Matyjasik, S. [International Laboratory of Strong Magnetic Fields and Low Temperatures (Poland); Novikova, N. E. [Russian Academy of Sciences, Shubnikov Institute of Crystallography (Russian Federation); Tseitlin, M.; Mozhaev, E. [Ariel University Center of Samaria (Israel); Roth, M. [Hebrew University, School of Applied Sciences (Israel)

    2010-11-15

    The temperature dependences of the pyroelectric coefficients of KTiOAsO{sub 4} and RbTiOAsO{sub 4} single crystals grown by flux crystallization have been investigated in the temperature range of 4.2-300 K. With an increase in temperature, superionic conductivity first arises in KTiOAsO4 (at T > 200 K) and then (at T > 270 K) in RbTiOAsO{sub 4}. This conductivity is much higher in the samples polarized at T = 4.2 K. An exponential change in the crystal resistivity along the polar direction is simultaneously observed. The results of measurements in the range of 4.2-200 K indicate larger values of pyroelectric coefficients when compared with potassium and rubidium titanyl-phosphate crystals. A correlation between the pyroelectric coefficients and a change in the lattice constants at isomorphic substitutions of K atoms for Rb and P atoms for As has been revealed within the symmetry approach.

  13. Effect of Low Temperature on a 4 W/60 K Pulse-Tube Cryocooler for Cooling HgCdTe Detector

    Science.gov (United States)

    Zhang, Ankuo; Liu, Shaoshuai; Wu, Yinong

    2018-04-01

    Temperature is an extremely important parameter for the material of the space-borne infrared detector. To cool an HgCdTe-infrared detector, a Stirling-type pulse-tube cryocooler (PTC) has been developed based on a great deal of numerical simulations, which are performed to investigate the thermodynamic behaviors of the PTC. The effects of different low temperatures are presented to analyze different energy flows, losses, phase shifts, and impedance matching of the PTC at a temperature range of 40-120 K, where woven wire screens are used. Finally, a high-efficiency coaxial PTC has been designed, built, and tested, operating around 60 K after a number of theoretical and experimental studies. The PTC can offer a no-load refrigeration temperature of 40 K with an input electric power of 150 W, and a cooling power of 4 W at 60 K is obtained with Carnot efficiency of 12%. In addition, a comparative study of simulation and experiment has been carried out, and some studies on reject temperatures have been presented for a thorough understanding of the PTC system.

  14. Transient thermal-hydraulic/neutronic analysis in a VVER-1000 reactor core

    International Nuclear Information System (INIS)

    Seyed khalil Mousavian; Mohammad Mohsen Ertejaei; Majid Shahabfar

    2005-01-01

    Full text of publication follows: Nowadays, coupled thermal-hydraulic and three-dimensional neutronic codes in order to consider different feedback effects is state of the art subject in nuclear engineering researches. In this study, RELAP5/COBRA and WIMS/CITATION codes are implemented to investigate the VVER-1000 reactor core parameters during Large Break Loss of Coolant Accident (LB-LOCA). In a LB-LOCA, the primary side pressure, coolant density and fuel temperature strongly decrease but the cladding temperature experiences a strong peak. For this purpose, the RELAP5 Best Estimate (BE) system code is used to simulate the LB-LOCA analysis in VVER-1000 nuclear thermal-hydraulic loops. Also, the modified COBRA-IIIc software as a sub-channel analysis code is applied for modeling of VVER-1000 reactor core. Moreover, WIMS and CITATION as a cross section and 3-D neutron flux codes are coupled with thermal-hydraulic codes with the aim of consider the spatial effects through the reactor core. For this reason, suitable software is developed to link and speed up the coupled thermalhydraulic and three-dimensional neutronic calculations. This software utilizes of external coupling concept in order to integrate thermal-hydraulic and neutronic calculations. (authors)

  15. K0/K+ ratio in relativistic heavy-ion collisions

    International Nuclear Information System (INIS)

    Ivanov, Yu.B.; Russkikh, V.N.

    1996-11-01

    It is shown that ratio of production yields of K 0 and K + mesons in collisions of isotopically asymmetric nuclei at incident energies ∼ 1 GeV/nucleon is related directly enough to temperature of nuclear matter at the initial stage of the collision. Sensitivity of the K 0 /K + ratio to the temperature variation is analyzed. Ambiguities, associated with interpretation of this quantity as a probe of nuclear temperature, are discussed. It is argued that the K 0 /K + ratio is a fairly model-independent quantity, provided channels with Δ isobars dominate the kaon production. (orig.)

  16. Neutron diffraction study of high temperature phase of K2SeO4

    International Nuclear Information System (INIS)

    Iwata, Yutaka; Koyano, Nobumitsu; Shibuya, Iwao; Hidaka, Masanori; Okazaki, Atsushi.

    1984-01-01

    The crystal structure of high-temperature phase of K 2 SeO 4 has been determined by means of single crystal neutron diffraction. The space group is P6 3 /mmc of hexagonal system with two formula units per unit cell. The structure is characterized by an averaged dispositions of SeO 4 tetrahedra with one of its Se-O bonds pointing parallel and antiparallel to the hexagonal c-axis in addition to the split distribution of potassium atoms. Heavily distorted distribution of oxygen atoms in SeO 4 is observed in Fourier maps corrersponding to split positions and reorientational motion of tetrahedra. This disordered arrangement is found to have close relation with the room temperature orthorhombic structure. The hexagonal-orthorhombic phase transition of K 2 SeO 4 at 472 0 C is grouped to an order-disorder type. (author)

  17. Stellar and Planetary Parameters for K2 's Late-type Dwarf Systems from C1 to C5

    Energy Technology Data Exchange (ETDEWEB)

    Martinez, Arturo O. [Department of Astronomy, San Diego State University, 5500 Campanile Drive, San Diego, CA 92182 (United States); Crossfield, Ian J. M.; Peacock, Sarah [Lunar and Planetary Laboratory, University of Arizona, 1629 E. University Blvd, Tucson, AZ 85721 (United States); Schlieder, Joshua E. [NASA Ames Research Center, Moffett Field, CA 94035 (United States); Dressing, Courtney D. [Division of Geological and Planetary Sciences, California Institute of Technology, Pasadena, CA 91125 (United States); Obermeier, Christian [Max Planck Institut für Astronomie, Heidelberg (Germany); Livingston, John; Petigura, Erik A. [Department of Astronomy, Graduate School of Science, The University of Tokyo, 7-3-1 Bunkyo-ku, Tokyo 113-0033 (Japan); Ciceri, Simona [Department of Astronomy, Stockholm University, SE-106 91 Stockholm (Sweden); Beichman, Charles A. [NASA Exoplanet Science Institute, California Institute of Technology, Pasadena, CA 91125 (United States); Lépine, Sébastien [Department of Physics and Astronomy, Georgia State University, 25 Park Pl NE #605, Atlanta, GA 30303 (United States); Aller, Kimberly M. [Institute for Astronomy, University of Hawai’i at Mānoa, 2680 Woodlawn Dr., Honolulu, HI 96822 (United States); Chance, Quadry A. [Steward Observatory, University of Arizona, 933 N. Cherry Ave, Tucson, AZ 85719 (United States); Howard, Andrew W. [Department of Astronomy, California Institute of Technology, Pasadena, CA 91125 (United States); Werner, Michael W. [Jet Propulsion Laboratory, 4800 Oak Grove Dr., Pasadena, CA 91109 (United States)

    2017-03-01

    The NASA K2 mission uses photometry to find planets transiting stars of various types. M dwarfs are of high interest since they host more short-period planets than any other type of main-sequence star and transiting planets around M dwarfs have deeper transits compared to other main-sequence stars. In this paper, we present stellar parameters from K and M dwarfs hosting transiting planet candidates discovered by our team. Using the SOFI spectrograph on the European Southern Observatory’s New Technology Telescope, we obtained R ≈ 1000 J -, H -, and K -band (0.95–2.52 μ m) spectra of 34 late-type K2 planet and candidate planet host systems and 12 bright K4–M5 dwarfs with interferometrically measured radii and effective temperatures. Out of our 34 late-type K2 targets, we identify 27 of these stars as M dwarfs. We measure equivalent widths of spectral features, derive calibration relations using stars with interferometric measurements, and estimate stellar radii, effective temperatures, masses, and luminosities for the K2 planet hosts. Our calibrations provide radii and temperatures with median uncertainties of 0.059 R {sub ⊙} (16.09%) and 160 K (4.33%), respectively. We then reassess the radii and equilibrium temperatures of known and candidate planets based on our spectroscopically derived stellar parameters. Since a planet’s radius and equilibrium temperature depend on the parameters of its host star, our study provides more precise planetary parameters for planets and candidates orbiting late-type stars observed with K2 . We find a median planet radius and an equilibrium temperature of approximately 3 R {sub ⊕} and 500 K, respectively, with several systems (K2-18b and K2-72e) receiving near-Earth-like levels of incident irradiation.

  18. OECD/DOE/CEA VVER-1000 Coolant Transient Benchmark. Summary Record of the Third Workshop (V1000-CT3)

    International Nuclear Information System (INIS)

    2005-01-01

    The overall objective of the VVER-1000 coolant transient (V1000CT) benchmark is to assess computer codes used in the safety analysis of VVER power plants, specifically for their use in analysis of reactivity transients in a VVER-1000. The V1000CT benchmark consists of two phases: V1000CT-1 is a simulation of the switching on of one main coolant pump (MCP) when the other three MCPs are in operation, and V1000CT-2 concerns calculation of coolant mixing tests and main steam line break (MSLB) scenarios. Each of the two phases contains three exercises. The reference problem chosen for simulation in Phase 1 is a MCP switching on when the other three main coolant pumps are in operation in a VVER-1000. This event is characterized by rapid increase in the flow through the core resulting in a coolant temperature decrease, which is spatially dependent. This leads to insertion of spatially distributed positive reactivity due to the modelled feedback mechanisms and non-symmetric power distribution. Simulation of the transient requires evaluation of core response from a multi-dimensional perspective (coupled three-dimensional neutronics/core thermal-hydraulics) supplemented by a one-dimensional simulation of the remainder of the reactor coolant system. Three exercises are defined in the framework of Phase 1: a) Exercise 1 - Point kinetics plant simulation; b) Exercise 2 - Coupled 3-D neutronics/core thermal-hydraulics response evaluation; c) Exercise 3 - Best-estimate coupled 3-D core/plant system transient modelling. In addition to the measured (experiment) scenario, extreme calculation scenarios were defined in the frame of Exercise 3 for better testing 3-D neutronics/thermal-hydraulics techniques. The proposals concerned: rod ejection simulations with scram set points at two different power levels. The technical topics presented at this workshop were: Review of the benchmark activities after the 2. Workshop; - Discussion of participant's feedback and introduced modifications

  19. The structure factor and the pair potential of liquid rubidium at temperatures between 450 K and 1,400 K

    International Nuclear Information System (INIS)

    Block de Priego, R.A.

    1977-11-01

    The structure factor S(Q) of liquid rubidium has been measured for temperatures between 450 K and 1400 K and pressures up to 200 atm. The corresponding densities varied between 1.42 and 0.98 g cm -3 . The incident energy of the neutrons was 3.4 MeV, the momentum transfer Q being 0.2 - 2.5 A -1 . A significant change in the order of the liquid has been registrated. Compressibility and electrical conductivity were derived from the structure factors and compared with the direct measured quantities, showing a good agreement. Further interpretation of the data was done by means of a hard core and a square well potential. Using these models it was already possible to get some information about the interactions between the rubidium atoms. A more exact calculation with a modified STLS model and a pseudopotential leads to a good description of the measured S(Q). In order to describe at high temperatures S(Q) for smaller values a new term had to be added to the pseudopotential. (orig.) [de

  20. Temperature reactivity coefficient of the RA reactor; Temperaturni koeficijenat reaktivnosti reaktora RA

    Energy Technology Data Exchange (ETDEWEB)

    Raisic, N; Strugar, P; Dobrosavljevic, N [Institute of Nuclear Sciences Boris Kidric, Vinca, Beograd (Serbia and Montenegro)

    1961-12-15

    Temperature reactivity coefficient of the RA reactor was determined as follows. Stabilization of moderator temperature and graphite reflector was achieved in the reactor operated at power levels of 20, 100, 500, 1000, 3000 and 5000 kW. Temperature change of the moderator was achieved by changing the water flow rate in the secondary cooling system. The fuel temperature was changed simultaneously. During the measurement at each power level the temperature change was between 30 - 50 deg C. Changing the position of the automated regulator is registered during moderator temperature change, and these changes were used for determining the total reactivity change by using the calibration curves for the automated regulator. In the measured temperature range the the reactivity change was linear and it was possible to determine the total temperature coefficient.

  1. An in situ Raman spectroscopy system for long-term corrosion experiments in high temperature water up to 673 K

    International Nuclear Information System (INIS)

    Domae, Masafumi; Tani, Jun-ichi; Fujiwara, Kazutoshi; Katsumura, Yosuke

    2006-01-01

    A Raman spectroscopy system has been developed, in order to identify oxides formed on the surfaces of metals and steels in high temperature water up to 673 K. A supercritical water loop system including a Raman cell was installed. The design of the loop system is up to 673 K and 40 MPa. The Raman cell has a diamond window without window-to-metal packing. Raman spectrum of alumina plate was measured at room temperature, at 523 and at 673 K under pressure of 25 MPa. A long-term measurement was also performed at 523 K and 25 MPa for 117.5 h. In all cases intense Raman peaks attributed to alumina were observed. Raman spectrum of anatase particles in suspension was measured at 673 K and 25 MPa. The results show that the Raman spectroscopy system developed in the present study works well not only for plate sample but also for suspension. Raman spectra observed for titanium plate in high temperature water of 673 K and 25 MPa show growth of several Raman peaks with time up to 257 h. The peaks disappeared after cooled down to room temperature. The experimental results have demonstrated importance of in situ Raman spectroscopy. (author)

  2. Design and construction of an adiabatic calorimeter for samples of less than 1 cm3 in the temperature range T = 15 K to T = 350 K

    International Nuclear Information System (INIS)

    Lang, Brian E.; Boerio-Goates, Juliana; Woodfield, Brian F.

    2006-01-01

    A small-scale adiabatic calorimeter has been constructed as part of a larger project to study the thermodynamics of nanomaterials and to facilitate heat capacity measurements on samples of insufficient quantity to run on our current large-scale adiabatic apparatus. This calorimeter is designed to measure the heat capacity of samples whose volume is less than 0.8 cm 3 over a temperature range of T = 13 K to T = 350 K. Heat capacity results on copper, sapphire, and benzoic acid show the accuracy of the measurements to be better than ±0.4% for temperatures higher than T = 50 K. The reproducibility of these measurements is generally better than ±0.25%

  3. Thermal conductivity and electrical resistivity of cadmium arsenide (Cd3As2) in the temperature range 4.2-40K1

    International Nuclear Information System (INIS)

    Bartkowski, K.; Ratalowicz, J.; Zdanowicz, W.

    1986-01-01

    Results on electrical resistivity and thermal conductivity measured in the temperature range 4.2-40 K are presented for single-crystal and polycrystalline samples of Cd 3 As 2 . Hall effect has been studied at temperatures of 4.2, 77, and 300K. The calculated value of the conduction electron concentration was in the range 1.87-1.95 10 24 m -3 . Electrical resistivity of all investigated samples was independent of temperature up to about 10K and increased slowsly at higher temperatures. The thermal conductivity shows a maximum in the region in which the lattice component of thermal conductivity dominates. The strong anistropy of the lattice component determines the anisotropy of the total thermal conductivity. The electronic component of thermal conductivity does not exhibit any anisotropy and shows a maximum at a temperature of about 300 K

  4. Fabrication of Tungsten-Rhenium Cladding materials via Spark Plasma Sintering for Ultra High Temperature Reactor Applications

    Energy Technology Data Exchange (ETDEWEB)

    Charit, Indrajit; Butt, Darryl; Frary, Megan; Carroll, Mark

    2012-11-05

    This research will develop an optimized, cost-effective method for producing high-purity tungsten-rhenium alloyed fuel clad forms that are crucial for the development of a very high-temperature nuclear reactor. The study will provide critical insight into the fundamental behavior (processing-microstructure- property correlations) of W-Re alloys made using this new fabrication process comprising high-energy ball milling (HEBM) and spark plasma sintering (SPS). A broader goal is to re-establish the U.S. lead in the research field of refractory alloys, such as W-Re systems, with potential applications in very high-temperature nuclear reactors. An essential long-term goal for nuclear power is to develop the capability of operating nuclear reactors at temperatures in excess of 1,000K. This capability has applications in space exploration and some special terrestrial uses where high temperatures are needed in certain chemical or reforming processes. Refractory alloys have been identified as being capable of withstanding temperatures in excess of 1,000K and are considered critical for the development of ultra hightemperature reactors. Tungsten alloys are known to possess extraordinary properties, such as excellent high-temperature capability, including the ability to resist leakage of fissile materials when used as a fuel clad. However, there are difficulties with the development of refractory alloys: 1) lack of basic experimental data on thermodynamics and mechanical and physical properties, and 2) challenges associated with processing these alloys.

  5. Development of 1000kW-class MCFC pilot plant

    Energy Technology Data Exchange (ETDEWEB)

    Ooue, M.; Yasue, H. [MCFC Research Association, Mie (Japan); Takasu, K.; Tsuchitori, T.

    1996-12-31

    This pilot plant is a part of the New Sunshine Program which has proceeded by the Agency of Industrial Science and Technology of the Ministry of International Trade and Industry. MCFC Research Association is entrusted with the development of the pilot plant, and constructing it at Kawagoe site. Following items will be verified by this pilot plant operation. (a) Development of 250kW class stack and confirmation of stack performance and decay rate. (b) System verification such as basic process, control system and operation characteristics, toward commercialization. (c) To get design data for demonstration plant.

  6. The elastic constants of MgSiO3 perovskite at pressures and temperatures of the Earth's mantle.

    Science.gov (United States)

    Oganov, A R; Brodholt, J P; Price, G D

    2001-06-21

    The temperature anomalies in the Earth's mantle associated with thermal convection can be inferred from seismic tomography, provided that the elastic properties of mantle minerals are known as a function of temperature at mantle pressures. At present, however, such information is difficult to obtain directly through laboratory experiments. We have therefore taken advantage of recent advances in computer technology, and have performed finite-temperature ab initio molecular dynamics simulations of the elastic properties of MgSiO3 perovskite, the major mineral of the lower mantle, at relevant thermodynamic conditions. When combined with the results from tomographic images of the mantle, our results indicate that the lower mantle is either significantly anelastic or compositionally heterogeneous on large scales. We found the temperature contrast between the coldest and hottest regions of the mantle, at a given depth, to be about 800 K at 1,000 km, 1,500 K at 2,000 km, and possibly over 2,000 K at the core-mantle boundary.

  7. Phase Transformations and Phase Equilibria in the Fe-N System at Temperatures below 573 K

    DEFF Research Database (Denmark)

    Malinov, S.; Böttger, A.J.; Mittemeijer, E.J.

    2001-01-01

    The phase transformations of homogeneous Fe-N alloys of nitrogen contents from 10 to 26 at. pct were investigated by means of X-ray diffraction analysis upon aging in the temperature range from 373 to 473 K. It was found that precipitation of alpha double prime-Fe16N2 below 443 K does not only oc...

  8. Effects of Re concentration on the expansivity of NiRe alloys to 1200 K NULL

    Science.gov (United States)

    Babu, V. Suresh; Seehra, Mohindar S.

    1998-08-01

    Measurements of the thermal expansion 0953-8984/10/33/006/img1 and hence the coefficient of thermal expansion 0953-8984/10/33/006/img2 are reported for 0953-8984/10/33/006/img3 alloys (x = 0, 5, 8, 10, 12, 16 and 25%) in the temperature range of 300 to 1300 K using a dilatometer. Room temperature x-ray diffraction studies show that for 0953-8984/10/33/006/img4%, a small fraction of Re begins to precipitate out, in addition to the dominant face-centred cubic (fcc) phase whose lattice constant increases linearly with x. The variations of 0953-8984/10/33/006/img2 with x plotted at selected temperatures of 503, 903 and 1203 K shows that for 0953-8984/10/33/006/img6%, 0953-8984/10/33/006/img2 decreases with increasing x at 503 and 903 K, whereas it remains practically constant with x at 1203 K. The latter result is in agreement with the predictions of Mei et al (1994 Alloy Modeling and Design ed G M Stocks and P E A Turchi (Warrendale, PA: TMS Publishing)) using molecular dynamics simulations. The variation of 0953-8984/10/33/006/img2 with x shows a minimum at x = 12% at all temperatures. The possible role of shear stresses in the dendritic grain structure of these alloys on measured 0953-8984/10/33/006/img2 below 1000 K is discussed.

  9. Phonon Anharmonicity of Germanium in the Temperature Range 80-880 K

    Energy Technology Data Exchange (ETDEWEB)

    Nelin, G; Nilsson, G

    1974-06-15

    Phonon frequency shifts and line widths in germanium have been studied in the temperature range 80 - 880 K by means of thermal neutron spectrometry. The results cannot be described in terms of the quasiharmonic approximation in which phonon frequencies are solely volume dependent. Theoretical calculations are found to be more satisfactory for the Raman frequency than for most other modes. A good account of the observed shifts is given by a proposal due to Barron according to which the relative frequency renormalization of a crystal is proportional to the total harmonic vibrational energy. An analysis of the gradients of measured dispersion relations in the principal symmetry directions at 80 K is presented. It is shown that accidental degeneracies may influence the dispersion

  10. Temperature-specific inhibition of human red cell Na+/K+ ATPase by 2450-MHz microwave radiation

    Energy Technology Data Exchange (ETDEWEB)

    Allis, J.W.; Sinha-Robinson, B.L.

    1987-01-01

    The ATPase activity in human red blood cell membranes was investigated in vitro as a function of temperature and exposure to 2450-MHz continuous wave microwave radiation to confirm and extend a report of Na+ transport inhibition under certain conditions of temperature and exposure. Assays were conducted spectrophotometrically during microwave exposure with a custom-made spectrophotometer-waveguide apparatus. Temperature profiles of total ATPase and Ca+2 ATPase (ouabain-inhibited) activity between 17 and 31 degrees C were graphed as an Arrhenius plot. Each data set was fitted to two straight lines which intersect between 23 and 24 degrees C. The difference between the total and Ca+2 ATPase activities, which represented the Na+/K+ ATPase activity, was also plotted and treated similarly to yield an intersection near 25 degrees C. Exposure of membrane suspensions to electromagnetic radiation, at a dose rate of 6 W/kg and at five temperatures between 23 and 27 degrees C, resulted in an activity change only for the Na+/K+ ATPase at 25 degrees C. The activity decreased by approximately 35% compared to sham-irradiated samples. A possible explanation for the unusual temperature/microwave interaction is proposed.

  11. Global IP6K1 deletion enhances temperature modulated energy expenditure which reduces carbohydrate and fat induced weight gain

    Directory of Open Access Journals (Sweden)

    Qingzhang Zhu

    2017-01-01

    Full Text Available Objective: IP6 kinases (IP6Ks regulate cell metabolism and survival. Mice with global (IP6K1-KO or adipocyte-specific (AdKO deletion of IP6K1 are protected from diet induced obesity (DIO at ambient (23 °C temperature. AdKO mice are lean primarily due to increased AMPK mediated thermogenic energy expenditure (EE. Thus, at thermoneutral (30 °C temperature, high fat diet (HFD-fed AdKO mice expend energy and gain body weight, similar to control mice. IP6K1 is ubiquitously expressed; thus, it is critical to determine to what extent the lean phenotype of global IP6K1-KO mice depends on environmental temperature. Furthermore, it is not known whether IP6K1 regulates AMPK mediated EE in cells, which do not express UCP1. Methods: Q-NMR, GTT, food intake, EE, QRT-PCR, histology, mitochondrial oxygen consumption rate (OCR, fatty acid metabolism assays, and immunoblot studies were conducted in IP6K1-KO and WT mice or cells. Results: Global IP6K1 deletion mediated enhancement in EE is impaired albeit not abolished at 30 °C. As a result, IP6K1-KO mice are protected from DIO, insulin resistance, and fatty liver even at 30 °C. Like AdKO, IP6K1-KO mice display enhanced adipose tissue browning. However, unlike AdKO mice, thermoneutrality only partly abolishes browning in IP6K1-KO mice. Cold (5 °C exposure enhances carbohydrate expenditure, whereas 23 °C and 30 °C promote fat oxidation in HFD-KO mice. Furthermore, IP6K1 deletion diminishes cellular fat accumulation via activation of the AMPK signaling pathway. Conclusions: Global deletion of IP6K1 ameliorates obesity and insulin resistance irrespective of the environmental temperature conditions, which strengthens its validity as an anti-obesity target. Keywords: IP6K, Obesity, Diabetes, Energy expenditure, β-oxidation

  12. Dusty plasma in a glow discharge in helium in temperature range of 5–300 K

    Energy Technology Data Exchange (ETDEWEB)

    Samoilov, I. S.; Baev, V. P.; Timofeev, A. V., E-mail: timofeevalvl@gmail.com; Amirov, R. Kh.; Kirillin, A. V.; Nikolaev, V. S.; Bedran, Z. V. [Russian Academy of Sciences, Joint Institute for High Temperatures (Russian Federation)

    2017-03-15

    Dusty plasma structures in glow discharge in helium in the temperature range of 5–300 K are investigated experimentally. We have described the experimental setup that makes it possible to continuously vary the temperature regime. The method for experimental data processing has been described. We have measured interparticle distances in the temperature range of 9–295 K and compared them with the Debye radius. We indicate the ranges of variations in experimental parameters in which plasma–dust structures are formed and various types of their behavior are manifested (rotation, vibrations of structures, formation of vertical linear chains, etc.). The applicability of the Yukawa potential to the description of the structural properties of a dusty plasma in the experimental conditions is discussed.

  13. Phytotoxicity of Sodium Fluoride and Uptake of Fluoride in Willow Trees

    DEFF Research Database (Denmark)

    Clausen, Lauge Peter Westergaard; Gosewinkel Karlson, Ulrich; Trapp, Stefan

    2015-01-01

    The willow tree (Salix viminalis) toxicity test and a cress seed germination test (Lepidium sativum) were used to determine uptake and phytotoxicity of NaF. Concentrations in hydroponic solutions were 0-1000 mg F/L and 0-400 mg F/L in the preliminary and definitive test. A third test was done...

  14. Apparatus to measure emissivities of metallic films between 90K and room temperature

    International Nuclear Information System (INIS)

    Bekeris, V.I.; Ramos, E.D.; Sanchez, D.H.

    1975-01-01

    The development of multilayer insulations is aerospace and cryogenic required to know the emissivity of the metallic films used as reflective layers. This work describes an emissometer that measures the total hemispherical emissivity of metallic films evaporated on polyester substrates. The apparatus works at liquid oxigen temperatures and permits to get emissivities from 90K to room temperatures within a 15% precision. The emissometer construction and operation are described in detail. Results of measurements done on Single Aluminized Mylar are presented [pt

  15. Apparatus to measure emissivities of metallic films between 90K and room temperature

    Energy Technology Data Exchange (ETDEWEB)

    Bekeris, V I [Nunez Univ. Nacional (Argentina). Faculdad de Ciencias Exactas Y Naturales; Ramos, E D [Santa Rosa Univ. Nacional (Argentina). Facultad de Ciencias Exactas Y Naturales; Sanchez, D H [Comision Nacional de Energia Atomica, San Carlos de Bariloche (Argentina). Centro Atomico Bariloche

    1975-09-01

    The development of multilayer insulations is aerospace and cryogenic required to know the emissivity of the metallic films used as reflective layers. This work describes an emissometer that measures the total hemispherical emissivity of metallic films evaporated on polyester substrates. The apparatus works at liquid oxigen temperatures and permits to get emissivities from 90K to room temperatures within a 15% precision. The emissometer construction and operation are described in detail. Results of measurements done on Single Aluminized Mylar are presented.

  16. Design of a self-aligned, wide temperature range (300 mK-300 K) atomic force microscope/magnetic force microscope with 10 nm magnetic force microscope resolution

    Energy Technology Data Exchange (ETDEWEB)

    Karcı, Özgür [NanoMagnetics Instruments Ltd., Hacettepe - İvedik OSB Teknokent, 1368. Cad., No: 61/33, 06370, Yenimahalle, Ankara (Turkey); Department of Nanotechnology and Nanomedicine, Hacettepe University, Beytepe, 06800 Ankara (Turkey); Dede, Münir [NanoMagnetics Instruments Ltd., Hacettepe - İvedik OSB Teknokent, 1368. Cad., No: 61/33, 06370, Yenimahalle, Ankara (Turkey); Oral, Ahmet, E-mail: orahmet@metu.edu.tr [Department of Physics, Middle East Technical University, 06800 Ankara (Turkey)

    2014-10-01

    We describe the design of a wide temperature range (300 mK-300 K) atomic force microscope/magnetic force microscope with a self-aligned fibre-cantilever mechanism. An alignment chip with alignment groves and a special mechanical design are used to eliminate tedious and time consuming fibre-cantilever alignment procedure for the entire temperature range. A low noise, Michelson fibre interferometer was integrated into the system for measuring deflection of the cantilever. The spectral noise density of the system was measured to be ~12 fm/√Hz at 4.2 K at 3 mW incident optical power. Abrikosov vortices in BSCCO(2212) single crystal sample and a high density hard disk sample were imaged at 10 nm resolution to demonstrate the performance of the system.

  17. Design of a self-aligned, wide temperature range (300 mK-300 K) atomic force microscope/magnetic force microscope with 10 nm magnetic force microscope resolution

    International Nuclear Information System (INIS)

    Karcı, Özgür; Dede, Münir; Oral, Ahmet

    2014-01-01

    We describe the design of a wide temperature range (300 mK-300 K) atomic force microscope/magnetic force microscope with a self-aligned fibre-cantilever mechanism. An alignment chip with alignment groves and a special mechanical design are used to eliminate tedious and time consuming fibre-cantilever alignment procedure for the entire temperature range. A low noise, Michelson fibre interferometer was integrated into the system for measuring deflection of the cantilever. The spectral noise density of the system was measured to be ∼12 fm/√Hz at 4.2 K at 3 mW incident optical power. Abrikosov vortices in BSCCO(2212) single crystal sample and a high density hard disk sample were imaged at 10 nm resolution to demonstrate the performance of the system

  18. 1000kW phosphoric acid fuel cell power plant. Outline of the plant

    Energy Technology Data Exchange (ETDEWEB)

    Shinobe, Kenji; Suzuki, Kazuo; Kaneko, Hideo

    1988-02-10

    The outline of the 1000KW phosphoric acid fuel cell power plant, developed as part of the Moonlight plan, was described. The plant was composed of 4 stacks of 260KW DC output. They were devided into two train with 680V and 765A. The generation efficiency of the plant was 40% and more. Steam reforming of natural gas was used. As the fuel, fuel cell exhaust gas was used in composition with the natural gas. The DC-AC inverter had an efficiency of 96%. The capacity of hot water generator and demineralized water plant for cell cooling were 2t/h and 1.6t/h, respectively, and air-system was incorporated. In September of 1987, the plant has succeeded in 1000KW power generation, and put in operation now. Under the 100% loaded condition, each cell had a voltage of 0.7V with little variation, and the current was 200mA/cm/sup 2/. No problems were found in cooling conditions and in the control of interpole differential pressure. The reformer has been operated for 1200h scince its commisioning, and had experiences of 100 times on start up-shut down operations, the reformer also indicated good performances in the gas compositions. The starting time of 8h and the load follow-up rate 10%/min remain as the subjects for shortening. DC-AC conversion was good. The concentration of NOx and the noise level satisfied the target values. (12 figs, 1 tab)

  19. Vapour pressure of D2O - Ice at temperatures below 237 K

    International Nuclear Information System (INIS)

    Heras, J.M.; Asensio, M.C.; Estiu, G.; Viscido, L.

    1984-01-01

    Accurate measurements of heavy water ice vapour pressures between 193 and 253 K have been carried out and an equation based on thermodynamic data has been derived in order to calculate the D 2 O-ice vapour pressures between 173 and 273 K. The agreement between our calculated vapour pressures and the available experimental data including those in this paper, is very good. The comparison between the theoretical calculations of H 2 O-ice and D 2 O-ice vapour pressures confirms the experimental evidence that H 2 O-ice is more volatile than D 2 O-ice at all temperatures in agreement with the vapour isotopic effect theory (VPIE).(author)

  20. Oxidation-induced embrittlement and structural changes of Zircaloy-4 tubing in steam at 700-1000 deg. C

    Energy Technology Data Exchange (ETDEWEB)

    Ali, A E; Huessein, A G; El-Sayed, A A; El Banna, O A [Atomic Energy Authority, Cairo (Egypt); El Raghy, S M [Cairo Univ. (Egypt). Faculty of Engineering

    1997-02-01

    The oxidation-induced embrittlement and structural changes of Zircaloy-4 (KWU-Type) tubing was investigated under light water reactors (LWR) Loss-of-Coolant. Accident conditions (LOCA) in temperature range 700-1000 deg. C. The effect of hydrogen addition to steam was also investigated in the temperature range 800-1000 deg. C. The oxidation-induced embrittlement was found to be a function of both temperature and time. Fractography investigation of oxidized tubing showed a typical brittle fracture in the stabilized-alpha zone. The microhardness measurements revealed that the alpha-Zr is harder than that near the mid-wall position. The oxidation-induced embrittlement at 900 deg. C was found to be higher than at 1000 deg. C. The results also indicated that the addition of 5% by volume hydrogen to steam resulted in an increase in the degree of embrittlement. (author). 22 refs, 9 figs, 3 tabs.

  1. Genomic Prediction from Whole Genome Sequence in Livestock: The 1000 Bull Genomes Project

    DEFF Research Database (Denmark)

    Hayes, Benjamin J; MacLeod, Iona M; Daetwyler, Hans D

    Advantages of using whole genome sequence data to predict genomic estimated breeding values (GEBV) include better persistence of accuracy of GEBV across generations and more accurate GEBV across breeds. The 1000 Bull Genomes Project provides a database of whole genome sequenced key ancestor bulls....... In a dairy data set, predictions using BayesRC and imputed sequence data from 1000 Bull Genomes were 2% more accurate than with 800k data. We could demonstrate the method identified causal mutations in some cases. Further improvements will come from more accurate imputation of sequence variant genotypes...

  2. Recent ion measurements within the modified DPF-1000U facility

    Directory of Open Access Journals (Sweden)

    Kwiatkowski Roch

    2015-06-01

    Full Text Available In this note we describe measurements of ion beams emitted along the z-axis of the DPF-1000U facility operated at 23 kV, 334 kJ, and with the initial deuterium pressure of 1.6–2 hPa. The DPF-1000U device was recently renewed and equipped with a dynamic gas-puff valve placed inside the inner electrode. The investigated ions were recorded by means of ion pinhole cameras equipped with solid state nuclear track detectors of the PM-355® (PADC type. The energy spectra of ions were determined using a Thomson spectrometer placed on the symmetry axis at a distance of 160 cm from the electrodes outlets. The ion images recorded during discharges performed under different experimental conditions show that the ion beams have a complex structure, usually in the form of a central bunch and an annular stream composed of many micro-beams. Energies of the registered deuterons have been in the range of 30–700 keV, while the fast protons (which originated from the hydrogen remnants had energies in the range of 300–850 keV.

  3. Efficacy of Vitamin K2 for Glucocorticoid-induced Osteoporosis in Patients with Systemic Autoimmune Diseases.

    Science.gov (United States)

    Shikano, Kotaro; Kaneko, Kaichi; Kawazoe, Mai; Kaburaki, Makoto; Hasunuma, Tomoko; Kawai, Shinichi

    2016-01-01

    Objective Vitamin K2 (menatetrenone) is an effective treatment for patients with postmenopausal osteoporosis. We herein performed a subanalysis of patients with systemic autoimmune diseases undergoing glucocorticoid therapy in our previous prospective study. Methods Sixty patients were categorized into a group with vitamin K2 treatment (n=20, Group A) and a group without vitamin K2 treatment (n=40, Group B). All patients were treated with bisphosphonates. Results Serum levels of osteocalcin and undercarboxylated osteocalcin decreased significantly after the start of glucocorticoid therapy in both groups, while the serum osteocalcin level was significantly higher in Group A than Group B during the third (p=0.0250) and fourth weeks (p=0.0155). The serum level of the N-terminal peptide of type I procollagen, a bone formation marker, decreased during glucocorticoid therapy, but was significantly higher in Group A than Group B during the fourth week (p=0.0400). The bone mineral density and fracture rate showed no significant differences between the two groups. Conclusion Although vitamin K2 improves bone turnover markers in patients with osteoporosis on glucocorticoid therapy, it has no significant effect on the bone mineral density and fracture rate after 1.5 years of treatment.

  4. Effects of gamma radiation and temperature on the biological assimilation and retention of /sup 137/Cs by Acheta domesticus (L. )

    Energy Technology Data Exchange (ETDEWEB)

    Van Hook, Jr, R I; Herbert, E T

    1971-12-01

    Cesium-137 retention was determined for brown crickets, Acheta domesticus, which had been irradiated with 0, 1000, 2500 and 5000 rad gamma radiation and maintained at 20, 25 and 30 degrees C. Parameters examined for temperature and dose effects were (1) per cent /sup 137/Cs assimilated into body tissues (p2), (2) rate of isotope passage through the gut (k1) and (3) rate of elimination of assimilated /sup 137/Cs (ks). Increases in temperature and gamma dose resulted in a general decrease in per cent /sup 137/Cs assimilated pe day (p2). The first-component elimination coefficient (k1) was not significantly affected (P less than or equal to 0.05) by either temperature or dose changes. Biological elimination coefficients for assimilated /sup 137/Cs (k2) increased with increasing temperature between doses of 0 and 2500 rad. Above 2500 rads however, increases in temperature had no noticeable effects on the rate of assimilated /sup 137/Cs excretion. At higher dose levels, radiation was the dominant factor influencing the parameter k2.

  5. Temperature behavior of electrical properties of high-k lead-magnesium-niobium titanate thin-films

    Energy Technology Data Exchange (ETDEWEB)

    Chen Wenbin, E-mail: cwb0201@163.com [Electromechanical Engineering College, Guilin University of Electronic Technology (China); McCarthy, Kevin G. [Department of Electrical and Electronic Engineering, University College Cork (Ireland); Copuroglu, Mehmet; O' Brien, Shane; Winfield, Richard; Mathewson, Alan [Tyndall National Institute, University College Cork (Ireland)

    2012-05-01

    This paper reports on the temperature dependence of the electrical properties of high-k lead-magnesium-niobium titanate thin films processed with different compositions (with and without nanoparticles) and with different annealing temperatures (450 Degree-Sign C and 750 Degree-Sign C). These characterization results support the ongoing investigation of the material's electrical properties which are necessary before the dielectric can be used in silicon-based IC applications.

  6. Effect of air condition on AP-1000 containment cooling performance in station black out accident

    International Nuclear Information System (INIS)

    Hendro Tjahjono

    2015-01-01

    AP1000 reactor is a nuclear power plant generation III+ 1000 MWe which apply passive cooling concept to anticipate accidents triggered by the extinction of the entire supply of electrical power or Station Black Out (SBO). In the AP1000 reactor, decay heat disposal mechanism conducted passively through the PRHR-IRWST and subsequently forwarded to the reactor containment. Containment externally cooled through natural convection in the air gap and through evaporation cooling water poured on the outer surface of the containment wall. The mechanism of evaporation of water into the air outside is strongly influenced by the conditions of humidity and air temperature. The purpose of this study was to determine the extent of the influence of the air condition on cooling capabilities of the AP1000 containment. The method used is to perform simulations using Matlab-based analytical calculation model capable of estimating the power of heat transferred. The simulation results showed a decrease in power up to 5% for relative humidity rose from 10% to 95%, while the variation of air temperature of 10°C to 40°C, the power will decrease up to 15%. It can be concluded that the effect of air temperature increase is much more significant in lowering the containment cooling ability compared with the increase of humidity. (author)

  7. Measurement of the ( p, , T) Properties for Pure Hydrocarbons at Temperatures up to 600 K and Pressures up to 200 MPa

    Science.gov (United States)

    Ito, T.; Nagata, Y.; Miyamoto, H.

    2014-10-01

    The data available for the thermodynamic properties of propane, -butane, and isobutane at temperatures above 440 K are outdated and show significant discrepancies with each other. The ambiguity associated with these data could be limiting to the development of any understanding related to the effects of mixing of these substances with other materials such as , ammonia, and non-flammable or lower-flammable HFC refrigerants. In this study, the ( p, , T) properties of propane, -butane, and isobutane were measured at temperatures ranging from (360 to 600) K and pressures ranging from (50 to 200) MPa. Precise measurements were carried out using a metal-bellows variable volumometer with a thermostatted air bath. The expanded uncertainties in the temperature, pressure, and density measurements were estimated to be 5 mK, 0.02 MPa, and 0.88 kg m ( K, MPa), 0.76 kg ( K, MPa), 0.76 kg ( K, MPa), and 2.94 kg ( K, MPa), respectively. The data obtained throughout this study were systematically compared with the calculated values derived from the available equations of state. These models agree well with the measured data at higher temperatures up to 600 K, demonstrating their suitability for an effective and precise examination of the mixing effects of potential alternative mixtures.

  8. AP1000 Design for Security

    International Nuclear Information System (INIS)

    Long, L.B.; Cummins, W.E.; Winters, J.W.

    2006-01-01

    Nuclear power plants are protected from potential security threats through a combination of robust structures around the primary system and other vital equipment, security systems and equipment, and defensive strategy. The overall objective for nuclear power plant security is to protect public health and safety by ensuring that attacks or sabotage do not challenge the ability to safely shutdown the plant or protect from radiological releases. In addition, plants have systems, features and operational strategies to cope with external conditions, such as loss of offsite power, which could be created as part of an attack. Westinghouse considered potential security threats during design of the AP1000 PWR. The differences in plant configuration, safety system design, and safe shutdown equipment between existing plants and AP1000 affect potential vulnerabilities. This paper provides an evaluation of AP1000 with respect to vulnerabilities to security threats. The AP1000 design differs from the design of operating PWRs in the US in the configuration and the functional requirements for safety systems. These differences are intentional departures from conventional PWR designs which simplify plant design and enhance overall safety. The differences between the AP1000 PWR and conventional PWRs can impact vulnerabilities to security threats. The NRC addressed security concerns as part of their reviews for AP1000 Design Certification, and did not identify any security issues of concern. However, much of the detailed security design information for the AP1000 was deferred to the combined Construction and Operating License (COL) phase as many of the security issues are site-specific. Therefore, NRC review of security issues related to the AP1000 is not necessarily complete. Further, since the AP1000 plant design differs from existing PWRs, it is not obvious that the analyses and assessments prepared for existing plants also apply to the AP1000. We conclude that, overall, the AP1000

  9. Measuring the internal temperature of a levitated nanoparticle in high vacuum

    Science.gov (United States)

    Hebestreit, Erik; Reimann, René; Frimmer, Martin; Novotny, Lukas

    2018-04-01

    The interaction of an object with its surrounding bath can lead to a coupling between the object's internal degrees of freedom and its center-of-mass motion. This coupling is especially important for nanomechanical oscillators, which are among the most promising systems for preparing macroscopic objects in quantum mechanical states. Here we exploit this coupling to derive the internal temperature of a levitated nanoparticle from measurements of its center-of-mass dynamics. For a laser-trapped silica particle in high vacuum, we find an internal temperature of 1000 (60 )K . The measurement and control of the internal temperature of nanomechanical oscillators is of fundamental importance because black-body emission sets limits to the coherence of macroscopic quantum states.

  10. Structure of spinel at high temperature using in-situ XANES study at the Al and Mg K-edge

    Energy Technology Data Exchange (ETDEWEB)

    Ligny, D de [Universite Claude Bernard Lyon 1, LPCML, 69622 Villeurbanne (France); Neuville, D R [Physique des Mineraux et Magmas, Geochimie-Cosmochimie, CNRS-IPGP, 4 place Jussieu, 75005 Paris (France); Flank, A-M; Lagarde, P, E-mail: deligny@pcml.univ-lyon1.f [Synchrotron SOLEIL, L' Orme des Merisiers, Saint Aubin, 91192 France (France)

    2009-11-15

    We present structural information obtained on spinel at high temperature (298-2400 K) using in situ XANES at the Mg and Al K-edge. Spinel, {sup [4]}(Al{sub x},Mg{sub 1-x}){sup [6]}(Al{sub 2-x},Mg{sub x})O{sub 4}, with increasing temperature, show a substitution of Mg by Al and Al by Mg in their respective sites. This substitution corresponds to an inversion of the Mg and Al sites. Furthermore, both experiments at the Al and Mg K-edges are in good agreement with XANES calculation made using FDMNES code.

  11. Measuring the microwave response of superconducting Nb:STO and Ti at mK temperatures using superconducting resonators

    Energy Technology Data Exchange (ETDEWEB)

    Thiemann, Markus; Beutel, Manfred; Dressel, Martin; Scheffler, Marc [1. Physikalisches Institut, Universitaet Stuttgart (Germany); Fillis-Tsirakis, Evangelos; Boschker, Hans; Mannhart, Jochen [Max Planck Institute for Solid State Research, Stuttgart (Germany)

    2016-07-01

    Niobium doped SrTiO{sub 3} is a superconductor, with the lowest charge carrier density among all superconductors. It shows a dome in the transition temperature as a function of doping concentration with a maximum T{sub c} ∼ 0.3 K. The superconducting dome may originate from the different bands being occupied depending on the doping level. The low energy scales of the system, as indicated by the low T{sub c} are within the GHz-regime. Therefore microwave measurements are a powerful technique to reveal the electronic properties of these superconductors. We preformed microwave measurements on Nb:STO of different doping levels in a dilution refrigerator, using superconducting stripline resonators. Measurements were done in a temperature and frequency range from 40-400 mK and 1-20 GHz, covering the normal and superconducting states. For comparison we also measured the temperature dependence of the surface impedance of superconducting titanium (T{sub c} ∼ 0.5 K), which can be well described by the Mattis-Bardeen equations with a ratio (2Δ)/(k{sub B}T{sub c}) = 3.56. Therefore titanium is an ideal reference sample representing a conventional BCS-superconductor.

  12. Use of /sup 59/Fe uptake in estimating the marrow dose in normal and splenectomized rats exposed to 1000 kVp x irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Maillie, H D; Baxter, R C; Lisman, H [Rochester Univ., N.Y. (USA). School of Medicine and Dentistry

    1977-11-01

    The /sup 59/Fe uptake system was used to estimate the dose distribution throughout sham-operated and splenectomized rats exposed to whole-body 1000 kVp x irradiation. The marrow in the splenectomized animals was found to be slightly more radiosensitive. However, the difference between the two groups of rats was not significant. The dose distributions throughout the marrow of both groups were the same. It was concluded that splenectomy had no effect on the usefulness of this method. The method of measuring /sup 59/Fe uptake in this study used the uptake of radioiron at 6 hr post-injection and the deduction of the activity due to circulating iron. This resulted in a technique capable of measuring changes in iron uptake with midline-air-exposures of 25 R.

  13. K-KIDS: The Imaging Survey for Stellar Companions at Solar System Scales Around More than 1000 K Dwarfs

    Science.gov (United States)

    Nusdeo, Daniel A.

    2018-01-01

    An initial sample of 1048 K dwarfs, hereafter known as the “K-KIDS” targets, was built from the Hipparcos and 2MASS catalogs in order to construct a robust list for a multiplicity survey. There have been two recent comprehensive stellar multiplicity surveys of low mass stars: Raghavan et. al. (2010) searched 454 solar-type stars and found a stellar multiplicity rate of 50%, and Winters et. al. (2017) surveyed 1121 M dwarfs and found a rate of 27%. A gap still remains in our understanding of the multiplicity rate of K dwarfs.For observational purposes, K-KIDS is confined equatorally to -30 < DEC < +30 to ensure that all stars are observable from either hemisphere, thereby creating a legacy sample that can be investigated for decades for stellar, brown dwarf, and planetary companions of various types. The RECONS team is conducting four companion surveys of these 1048 stars, including imaging surveys at various separations --- large (10+ arcseconds), medium (2–10 arcseconds), and small (0.02–2 arcseconds) --- and a radial velocity survey for the closest companions. Here we report on the small separation survey that targets scales similar to our Solar System, 0.1-100 AU, carried out using the Differential Speckle Survey Instrument on the Gemini and WIYN telescopes. To date, we have observed 964 out of 1048 systems, already finding 135 companions. We present a sample of K dwarf double stars with separations less than 100 AU, of which the vast majority are new discoveries. Further progress on the medium and large separation regimes ensures that a statistically significant stellar multiplicity rate for K dwarfs will soon be in achieved, which can then be investigated for dependences on, for example, stellar age and metallicity.This effort has been supported by the NSF through grant AST-1517413 and via observations obtained at the Gemini Observatory (North and South telescopes), which is operated by AURA under a cooperative agreement with the NSF on behalf of the

  14. Cooling of high temperature superconductors below 60 K by means of a two-stage cryogenic mixed refrigerant cascade; Kuehlung von Hochtemperatursupraleitern unterhalb von 60 K mittels einer zweistufigen Gemischkaeltekaskade

    Energy Technology Data Exchange (ETDEWEB)

    Kochenburger, T.M. [Karlsruher Institut fuer Technologie (KIT), Karlsruhe (Germany). Inst. fuer Technische Thermodynamik und Kaeltetechnik (ITTK); Grohmann, S. [Karlsruher Institut fuer Technologie (KIT), Karlsruhe (Germany). Inst. fuer Technische Thermodynamik und Kaeltetechnik (ITTK); Karlsruher Institut fuer Technologie (KIT), Eggenstein-Leopoldshafen (Germany). Inst. fuer Technische Physik (ITEP)

    2015-07-01

    High temperature superconductors enable the efficient transmission of electrical energy in urban and industrial networks. It is the availability of simple, reliable and at the same time efficient cooling methods prerequisite for the application of this technology. At operating temperatures 65-80 K is the cooling currently mostly implemented by liquid nitrogen, large-scale turbo-Brayton plants or batteries of regenerative cryocooler; however, all these options for applications in the range of a few kW of required cooling capacity have thermodynamic, economic and practical limitations. In addition, a further lowering the cooling temperature below 60 K is desirable to increase the current density in the superconductors. Two-stage cryogenic mixed refrigerant cascade offer the potential for a reliable and easily scalable alternative for refrigeration in this temperature range. The first stage of the considered process consists of a classic mixture refrigeration cycle to pre-cool to 120 K. The second stage operates in the low temperature range up to 55 K with a mixture of nitrogen, oxygen and neon at high pressures. This paper compares on the basis of experimental data, the performance of combustible and non-combustible mixtures in the precooling level. The applicability of various equations of state for modeling of phase behavior of mixtures is discussed. [German] Hochtemperatursupraleiter ermoeglichen den effizienten Transport elektrischer Energie in urbanen und industriellen Netzen. Dabei ist die Verfuegbarkeit von einfachen, zuverlaessigen und gleichzeitig effizienten Kuehlmethoden Voraussetzung fuer die Anwendung dieser Technologie. Bei Betriebstemperaturen von 65 - 80 K wird die Kuehlung derzeit meist durch Fluessigstickstoff, grossskalige Turbo-Brayton-Anlagen oder Batterien regenerativer Kleinkuehler realisiert; jedoch haben alle diese Optionen fuer Anwendungen im Bereich von einigen kW an erforderlicher Kaelteleistung thermodynamische, oekonomische und

  15. Thermodynamic investigation of methyl salicylate/1-pentanol binary system in the temperature range from 278.15K to 303.15K

    International Nuclear Information System (INIS)

    Tsierkezos, Nikos G.; Molinou, Ioanna E.

    2007-01-01

    Densities (ρ), speeds of sound (u), isentropic compressibilities (k s ), refractive indices (n D ), and surface tensions (σ) of binary mixtures of methyl salicylate (MSL) with 1-pentanol (PEN) have been measured over the entire composition range at the temperatures of 278.15K, 288.15K, and 303.15K. The excess molar volumes (V E ), excess surface tensions (σ E ), deviations in speed of sound (Δu), deviations in isentropic compressibility (Δk s ), and deviations in molar refraction (ΔR) have been calculated. The excess thermodynamic properties V E , σ E , Δu, Δk s , and ΔR were fitted to the Redlich-Kister polynomial equation and the A k coefficients as well as the standard deviations (d) between the calculated and experimental values have been derived. The surface tension (σ) values have been further used for the calculation of the surface entropy (S S ) and the surface enthalpy (H S ) per unit surface area. The lyophobicity (β) and the surface mole fraction (x 2 S ) of the surfactant component PEN have been also derived using the extended Langmuir model. The results provide information on the molecular interactions between the unlike molecules that take place at the surface and the bulk

  16. Hot deformation and processing maps of K310 cold work tool steel

    International Nuclear Information System (INIS)

    Ezatpour, H.R.; Sajjadi, S.A.; Haddad-Sabzevar, M.; Ebrahimi, G.R.

    2012-01-01

    Highlights: ► The steady state stresses are related to strain rate and temperature. ► The study led to n DRX = 3.95 and Q DRX = 219.65 kJ/(mol K) and α = 1.2 × 10 −2 MPa −1 . ► The safe domain occurs in the region of 1000–1100 °C for a strain rate of 0.1 s −1 . - Abstract: Hot working response of cold work tool steel K310 was investigated by means of compression test at temperature range of 900–1100 °C. The equivalent strain rates used in these tests were 0.01, 0.1 and 1 s −1 , respectively in order to obtain the processing and stability maps of the studied material following the Dynamic Material Model. All the zones of flow instability were studied through scanning electron microscopy (SEM). The microstructure of the samples after deformation was then analyzed by light microscopy and the differences were compared together. The steady state stress obtained from the flow curves was related to strain rate (ε . ) and temperature (T) by means of the well known Zener–Holloman equation. A least square analysis of the data led to n = 3.95 and Q DRX = 219.65 kJ/mol and α = 1.2 × 10 −2 MPa −1 . Also, hardness results showed that by increasing strain from peak to steady state strain, hardness was decreased.

  17. Westinghouse AP1000 licensing maturity

    International Nuclear Information System (INIS)

    Schulz, T.; Vijuk, R.P.

    2005-01-01

    The Westinghouse AP1000 Program is aimed at making available a nuclear power plant that is economical in the U.S deregulated electrical power industry in the near-term. The AP1000 is two-loop 1000 MWe pressurizer water reactor (PWR). It is an up rated version of the AP600. The AP1000 uses passive safety systems to provide significant and measurable improvements in plant simplification, safety, reliability, investment protection and plant costs. The AP1000 uses proven technology, which builds on over 35 years of operating PWR experience. The AP1000 received Final Design Approval by the United States Nuclear Regulatory Commission (U.S. NRC) in September 2004. The AP1000 meets the US utility requirements. The AP1000 and its sister plant the AP600 have gone through a very through and complete licensing review. This paper describes the U.S. NRC review efforts of both the AP600 and the AP1000. The detail of the review and the independent calculations, evaluations and testing is discussed. The AP600 licensing documentation was submitted in 1992. The U.S. NRC granted Final Design Approval in 1999. During the intervening 7 years, the U.S. NRC asked thousands of questions, performed independent safety analysis, audited Westinghouse calculations and analysis, and performed independent testing. The more significant areas of discussion will be described. For the AP1000 Westinghouse first engaged the U.S. NRC in pre-certification discussions to define the extent of the review required, since the design is so similar to the AP600. The AP1000 licensing documentation was submitted in March 2002. The U.S. NRC granted Final Design Approval in September 2004. During the intervening 2 1/2 years, the U.S. NRC asked hundreds of questions, performed independent safety analysis, audited Westinghouse calculations and analysis, and performed independent testing. The more significant areas of discussion will be described. The implications of this review and approval on AP1000 applications in

  18. Reaction OH + OH studied over the 298-834 K temperature and 1-100 bar pressure ranges.

    Science.gov (United States)

    Sangwan, Manuvesh; Chesnokov, Evgeni N; Krasnoperov, Lev N

    2012-06-21

    Self-reaction of hydroxyl radicals, OH + OH → H(2)O + O (1a) and OH + OH → H(2)O(2) (1b), was studied using pulsed laser photolysis coupled to transient UV-vis absorption spectroscopy over the 298-834 K temperature and 1-100 bar pressure ranges (bath gas He). A heatable high-pressure flow reactor was employed. Hydroxyl radicals were prepared using reaction of electronically excited oxygen atoms, O((1)D), produced in photolysis of N(2)O at 193 nm, with H(2)O. The temporal behavior of OH radicals was monitored via transient absorption of light from a dc discharge in H(2)O/Ar low-pressure resonance lamp at ca. 308 nm. The absolute intensity of the photolysis light was determined by accurate in situ actinometry based on the ozone formation in the presence of molecular oxygen. The results of this study combined with the literature data indicate that the rate constant of reaction 1a, associated with the pressure independent component, decreases with temperature within the temperature range 298-414 K and increases above 555 K. The pressure dependent rate constant for (1b) was parametrized using the Troe expression as k(1b,inf) = (2.4 ± 0.6) × 10(-11)(T/300)(-0.5) cm(3) molecule(-1) s(-1), k(1b,0) = [He] (9.0 ± 2.2) × 10(-31)(T/300)(-3.5±0.5) cm(3) molecule(-1) s(-1), F(c) = 0.37.

  19. Gas phase kinetics of the OH + CH3CH2OH reaction at temperatures of the interstellar medium (T = 21-107 K).

    Science.gov (United States)

    Ocaña, A J; Blázquez, S; Ballesteros, B; Canosa, A; Antiñolo, M; Albaladejo, J; Jiménez, E

    2018-02-21

    Ethanol, CH 3 CH 2 OH, has been unveiled in the interstellar medium (ISM) by radioastronomy and it is thought to be released into the gas phase after the warm-up phase of the grain surface, where it is formed. Once in the gas phase, it can be destroyed by different reactions with atomic and radical species, such as hydroxyl (OH) radicals. The knowledge of the rate coefficients of all these processes at temperatures of the ISM is essential in the accurate interpretation of the observed abundances. In this work, we have determined the rate coefficient for the reaction of OH with CH 3 CH 2 OH (k(T)) between 21 and 107 K by employing the pulsed and continuous CRESU (Cinétique de Réaction en Ecoulement Supersonique Uniforme, which means Reaction Kinetics in a Uniform Supersonic Flow) technique. The pulsed laser photolysis technique was used for generating OH radicals, whose time evolution was monitored by laser induced fluorescence. An increase of approximately 4 times was observed for k(21 K) with respect to k(107 K). With respect to k(300 K), the OH-reactivity at 21 K is enhanced by two orders of magnitude. The obtained T-expression in the investigated temperature range is k(T) = (2.1 ± 0.5) × 10 -11 (T/300 K) -(0.71±0.10) cm 3 molecule -1 s -1 . In addition, the pressure dependence of k(T) has been investigated at several temperatures between 21 K and 90 K. No pressure dependence of k(T) was observed in the investigated ranges. This may imply that this reaction is purely bimolecular or that the high-pressure limit is reached at the lowest total pressure experimentally accessible in our system. From our results, k(T) at usual IS temperatures (∼10-100 K) is confirmed to be very fast. Typical rate coefficients can be considered to range within about 4 × 10 -11 cm 3 molecule -1 s -1 at 100 K and around 1 × 10 -10 cm 3 molecule -1 s -1 at 20 K. The extrapolation of k at the lowest temperatures of the dense molecular clouds of ISM is also discussed in this paper.

  20. Partial molar volumes of organic solutes in water. XXIV. Selected alkane-α,ω-diols at temperatures T = 298 K to 573 K and pressures up to 30 MPa

    International Nuclear Information System (INIS)

    Cibulka, Ivan; Hnědkovský, Lubomír

    2013-01-01

    Highlights: • Standard molar volumes of three alkane-α,ω-diols (C 5 , C 8 , C 9 ) in water are presented. • Data were obtained in the range T from (298 to 573) K and p up to 30 MPa. • Dependences on carbon atom number, temperature, and pressure are analysed. -- Abstract: Density data for dilute aqueous solutions of three alkane-α,ω-diols (pentane-1,5-diol, octane-1,8-diol, nonane-1,9-diol) are presented together with standard molar volumes (partial molar volumes at infinite dilution) calculated from the experimental data. The measurements were performed at temperatures from T = 298 K up to T = 573 K. Experimental pressures were slightly above the saturation vapour pressure of water, and (15 and 30) MPa. The data were obtained using a high-temperature high-pressure flow vibrating-tube densimeter. Measured standard molar volumes were combined with data previously published for other members of the homologous series and discussed. Experimental standard molar volumes were correlated as a function of temperature and pressure using an empirical polynomial function. Dependences of standard molar volumes on temperature and pressure were analysed. Contributions of the methylene group to the standard molar volume were also evaluated and discussed

  1. Steam turbine of WWER-1000 unit

    International Nuclear Information System (INIS)

    Drahy, J.

    1986-01-01

    The manufacture was started by Skoda of a saturated steam, 1,000 MW, 3,000 rpm turbine designed for the Temelin nuclear power plant. The turbine provides steam for heating water for district heating, this either with an output of 893 MW for a three-stage water heating at 150/60 degC, or of 570 MW for a two-stage water heating at 120/60 degC. The turbine features one high-pressure and three identical low-pressure stages. The pressure gradient between the high-pressure and the low-pressure parts was optimized with respect to the thermal efficiency of the cycle and to the thermodynamic efficiency of the low-pressure part. A value of 0.79 MPa was selected corresponding to the maximum through-flow of steam entering the turbine. This makes 5,495 t/h, the admission steam parameters are 273.3 degC and 5.8 MPa. The feed water temperature is 220.9 degC. 300 cold starts, 1,000 starts after shutdowns for 55 to 88 hours and 600 starts after shutdown for 8 hours are envisaged for the entire turbine service life. (Z.M.). 5 figs., 1 tab., 6 refs

  2. Present status of high temperature engineering test and research, 1994

    International Nuclear Information System (INIS)

    1994-10-01

    High temperature gas-cooled reactors have excellent features such as the generation of high temperature close to 1000degC, very high inherent safety and high fuel burnup. By the advanced basic research under high temperature irradiation condition, the creation of various new technologies which become the momentum of future technical innovation can be expected. The construction of the high temperature engineering test reactor (HTTR) was decided in 1987, which aims at the thermal output of 30 MW and the coolant temperature at reactor exit of 950degC. The initial criticality is scheduled in 1998. Japan Atomic Energy Research Institute has advanced the high temperature engineering test and research, and plans the safety verifying test of the HTTR, the test of connecting heat utilization plants and so on. In this report, mainly the results obtained for one year from May, 1993 are summarized. The outline of the high temperature engineering test and development of the HTTR technologies are reported. (K.I.)

  3. ANALISIS EFEK KECELAKAAN WATER INGRESS TERHADAP REAKTIVITAS DOPPLER TERAS RGTT200K

    Directory of Open Access Journals (Sweden)

    Zuhair Zuhair

    2015-03-01

    Full Text Available Dalam high temperature reactor, koefisien reaktivitas temperatur yang didesain negatif menjamin reaksi fisi dalam teras tetap berada di bawah kendali dan panas peluruhan tidak akan pernah melelehkan bahan bakar yang menyebabkan terlepasnya zat radioaktif ke lingkungan. Namun masuknya air (water ingress ke dalam teras reaktor akibat pecahnya tabung penukar panas generator uap, yang dikenal sebagai salah satu kecelakaan dasar desain, dapat mengintroduksi reaktivitas positif dengan potensi bahaya lainnya seperti korosi grafit dan kerusakan material struktur reflektor. Makalah ini akan menganalisis efek kecelakaan water ingress terhadap reaktivitas Doppler teras RGTT200K. Kapabilitas koefisien reaktivitas Doppler untuk mengkompensasi reaktivitas positif yang timbul selama kecelakaan water ingress akan diuji melalui serangkaian perhitungan dengan program MCNPX dan pustaka ENDF/B-VII untuk perubahan temperatur bahan bakar dari 800K hingga 1800K. Tiga opsi kernel bahan bakar UO2, ThO2/UO2 dan PuO2 dengan tiga model kisi bahan bakar pebble di teras reaktor diterapkan untuk kondisi water ingress dengan densitas air dari 0 hingga 1.000 kg/m3. Hasil perhitungan memperlihatkan koefisien reaktivitas Doppler tetap negatif untuk seluruh opsi bahan bakar yang dipertimbangkan bahkan untuk posibilitas water ingress yang besar. Efek water ingress lebih kuat pada model kisi dengan fraksi packing lebih rendah karena lebih banyak volume yang tersedia untuk air yang memasuki teras reaktor. Efek water ingress juga lebih kuat di teras uranium dibandingkan teras thorium dan plutonium sebagai konsekuensi dari fenomena Doppler dimana absorpsi neutron di daerah resonansi 238U lebih besar daripada 232Th dan 240Pu. Secara keseluruhan dapat disimpulkan bahwa, koefisien Doppler teras RGTT200K mampu mengkompensasi insersi reaktivitas yang diintroduksi oleh kecelakaan water ingress. Teras RGTT200K dengan bahan bakar UO2, ThO2/UO2 dan PuO2 dapat mempertahankan fitur keselamatan

  4. 47 CFR 76.1000 - Definitions.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false Definitions. 76.1000 Section 76.1000 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES MULTICHANNEL VIDEO AND CABLE TELEVISION SERVICE Competitive Access to Cable Programming § 76.1000 Definitions. As used in this...

  5. 7 CFR 3017.1000 - Respondent.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 15 2010-01-01 2010-01-01 false Respondent. 3017.1000 Section 3017.1000 Agriculture Regulations of the Department of Agriculture (Continued) OFFICE OF THE CHIEF FINANCIAL OFFICER, DEPARTMENT OF AGRICULTURE GOVERNMENTWIDE DEBARMENT AND SUSPENSION (NONPROCUREMENT) Definitions § 3017.1000 Respondent...

  6. Measurement of the enthalpy and specific heat of a Be2C-graphite-UC2 reactor fuel material to 19800K

    International Nuclear Information System (INIS)

    Roth, E.P.

    1980-01-01

    The enthalpy and specific heat of a Be 2 C-graphite-UC 2 composite nuclear fuel material were measured over the temperature range 300 to 1980 0 K using differential scanning calorimetry and liquid argon vaporization calorimetry. The fuel material measured was developed at Sandia National Laboratories for use in pulsed test reactors. The material is a hot-pressed composite consisting of 40 vol % Be 2 C, 49.5 vol % graphite, 3.5 vol % UC 2 and 7.0 vol % void. The specific heat was measured with the differential scanning calorimeter over the temperature range 300 to 950 0 K while the enthalpy was measured over the range 1185 to 1980 0 K with the liquid argon vaporization calorimeter. The normal spectral emittance at a wavelength of 6.5 x 10 -5 cm was measured over the experimental temperature range. The combined experimental enthalpy data were fit using a spline routine and differentiated to give the specific heat. Comparison of the measured specific heat of the composite to the specific heat calculated by summing the contributions of the individual components indicates that the specific heat of the Be 2 C component differs significantly from literature values and is approximately 0.6 cal/g-K (2.5 x 10 3 J/Kg-K) for temperatures above 1000 0 K

  7. Mechanical properties and dependence with temperature of tetragonal polycrystalline zirconia materials

    International Nuclear Information System (INIS)

    Orange, G.

    1986-01-01

    Polycrystalline zirconia materials with a high content of metastable tetragonal phase have been obtained by pressureless sintering from experimental powders. Mechanical properties have been determined at room temperature and compared with similar materials. The fracture strength (σ /SUB f/ ) and fracture toughness (K /SUB 1c/ ) temperature dependence has been studied, in air environment up to 1000 0 C. Microstructure was studied by SEM examinations of fracture faces and TEM observations. Fracture toughness (of about 10 MPa √m at room temperature) decreases from 200 0 C to 800 0 C. The critical temperature (T /SUB c/ ) is estimated at 600 0 C. We observe an important decreases of fracture strength at 200 0 C. These mechanical properties are discussed on the basis of the stability of the tetragonal phase depending on additive content, grain size and temperature

  8. Solution of the 'MIDICORE' WWER-1000 core periphery power distribution benchmark by KARATE and MCNP

    International Nuclear Information System (INIS)

    Temesvari, E.; Hegyi, G.; Hordosy, G.; Maraczy, C.

    2011-01-01

    The 'MIDICORE' WWER-1000 core periphery power distribution benchmark was proposed by Mr. Mikolas on the twentieth Symposium of AER in Finland in 2010. This MIDICORE benchmark is a two-dimensional calculation benchmark based on the WWER-1000 reactor core cold state geometry with taking into account the geometry of explicit radial reflector. The main task of the benchmark is to test the pin by pin power distribution in selected fuel assemblies at the periphery of the WWER-1000 core. In this paper we present our results (k eff , integral fission power) calculated by MCNP and the KARATE code system in KFKI-AEKI and the comparison to the preliminary reference Monte Carlo calculation results made by NRI, Rez. (Authors)

  9. Critical Temperature of Randomly Diluted Two-Dimensional Heisenberg Ferromagnet, K2CuxZn(1-x)F4

    Science.gov (United States)

    Okuda, Yuichi; Tohi, Yasuto; Yamada, Isao; Haseda, Taiichiro

    1980-09-01

    The susceptibility of randomly diluted two-dimensional Heisenberg-like ferromagnet K2CuxZn(1-x)F4 was measured down to 50 mK, using the 3He-4He dilution refrigerator and a SQUID magnetometer. The ferromagnetic critical temperature Tc(x) was obtained for x{=}0.98, 0.94, 0.85, 0.82, 0.68, 0.60, 0.54, 0.50 and 0.42. The value of [1/Tc(1)][(d/dx)Tc(x)]x=1 was approximately 3.0. The critical temperature versus x curve exhibits a noticeable tail near the critical concentration, which may stem from the second nearest-neighbor interaction. The critical concentration xc, below which concentration there is no long range order down to T{=}0 K, was estimated to be 0.45˜0.50. The susceptibility of sample with x{=}0.42 behaves as if it obeys the Curie law down to 50 mK.

  10. Studies of Mn0.5Cr0.5Fe2O4 ferrite by neutron diffraction at different temperatures in the range 768K ≥ T ≥ 13K

    International Nuclear Information System (INIS)

    Zakaria, A.K.M.; Ahmed, F.U.; Azad, A.K.; Yunus, S.M.; Asgar, M.A.; Paranjpe, S.K.; Das, A.

    2002-01-01

    Neutron diffraction studies of a polycrystalline manganese-chromium- ferrite with composition Mn 0.5 Cr 0.5 Fe 2 O 4 have been performed at a number of temperatures in the range 768K ≥ T ≥ 13K. The cation distributions, oxygen position parameter (u) and lattice constant (a o ) have been determined from the analysis of the higher angle neutron diffraction data. The temperature response of the lattice constant has also been investigated and a slight anomalous expansion has been found around the magnetic transition temperature. Sublattice as well as net ferrimagnetic moments of the specimen have been found out from the analysis of the neutron diffraction data at different temperatures. A randomly canted ordering of spins has been observed in the B sublattice, while the A sublattice moments appear to exhibit collinear Neel type ordering at all temperatures. (author)

  11. 40 CFR 725.1000 - Scope.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Scope. 725.1000 Section 725.1000 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC SUBSTANCES CONTROL ACT REPORTING....1000 Scope. This subpart identifies uses of microorganisms which EPA has determined to be significant...

  12. 40 CFR 51.1000 - Definitions.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 2 2010-07-01 2010-07-01 false Definitions. 51.1000 Section 51.1000 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS REQUIREMENTS FOR... Ambient Air Quality Standards § 51.1000 Definitions. The following definitions apply for purposes of this...

  13. 7 CFR 760.1000 - Applicability.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 7 2010-01-01 2010-01-01 false Applicability. 760.1000 Section 760.1000 Agriculture Regulations of the Department of Agriculture (Continued) FARM SERVICE AGENCY, DEPARTMENT OF AGRICULTURE... Catfish Grant Programs § 760.1000 Applicability. (a) This subpart establishes the terms and conditions...

  14. Vitrification of Simulated Fernald K-65 Silo Waste at Low Temperature

    International Nuclear Information System (INIS)

    Jantzen, C.M.; Pickett, J.B.

    1998-01-01

    Vitrification is the technology that has been chosen to solidify approximately 15,500 tons of geologic mill tailings at the Fernald Environmental Management Project (FEMP) in Fernald, Ohio. The geologic mill tailings are residues from the processing of pitchlende ore during 1949-1958. These waste residues are contained in silos in Operable Unit 4 (OU4) at the FEMP facility. Operable Unit 4 is one of five operable units at the FEMP. Operating Unit 4 consists of four concrete storage silos and their contents. Silos 1 and 2 contain K-65 mill tailing residues and a bentonite cap, Silo 3 contains non-radioactive metal oxides, and Silo 4 is empty. The K-65 residues contain radium, uranium, uranium daughter products, and heavy metals such as lead and barium.The K-65 waste leaches lead at greater than 100 times the allowable Environmental Protection Agency (EPA) Resource, Conservation, and Recovery Act (RCRA) concentration limits when tested by the Toxic Characteristic Leaching Procedure (TCLP). Vitrification was chosen by FEMP as the preferred technology for the Silos 1, 2, 3 wastes because the final waste form met the following criteria: controls radon emanation, eliminates the potential for hazardous or radioactive constituents to migrate to the aquifer below FEMP, controls the spread of radioactive particulates, reduces leachability of metals and radiological constituents, reduces volume of final wasteform for disposal, silo waste composition is favorable to vitrification, will meet current and proposed RCRA TCLP leaching criteria Glasses that melt at 1350 degrees C were developed by Pacific Northwest National Laboratory (PNNL) and glasses that melt between 1150-1350 degrees C were developed by the Vitreous State Laboratory (VSL) for the K-65 silo wastes. Both crucible studies and pilot scale vitrification studies were conducted by PNNL and VSL. Subsequently, a Vitrification Pilot Plant (VPP) was constructed at FEMP capable of operating at temperatures up to 1450

  15. Thermodynamic investigation of methyl salicylate/1-pentanol binary system in the temperature range from 278.15K to 303.15K

    Energy Technology Data Exchange (ETDEWEB)

    Tsierkezos, Nikos G. [Institut fuer Chemie, Humboldt-Universitaet zu Berlin, Brook-Taylor-Strasse 2, D-12489 Berlin (Germany)]. E-mail: tsierkezos@chemie.hu-berlin.de; Molinou, Ioanna E. [Physical Chemistry Laboratory, Department of Chemistry, University of Athens, Panepistimiopolis, Athens 15771 (Greece)]. E-mail: imolinou@chem.uoa.gr

    2007-08-15

    Densities ({rho}), speeds of sound (u), isentropic compressibilities (k{sub s}), refractive indices (n{sub D}), and surface tensions ({sigma}) of binary mixtures of methyl salicylate (MSL) with 1-pentanol (PEN) have been measured over the entire composition range at the temperatures of 278.15K, 288.15K, and 303.15K. The excess molar volumes (V{sup E}), excess surface tensions ({sigma}{sup E}), deviations in speed of sound ({delta}u), deviations in isentropic compressibility ({delta}k{sub s}), and deviations in molar refraction ({delta}R) have been calculated. The excess thermodynamic properties V{sup E}, {sigma}{sup E}, {delta}u, {delta}k{sub s}, and {delta}R were fitted to the Redlich-Kister polynomial equation and the A{sub k} coefficients as well as the standard deviations (d) between the calculated and experimental values have been derived. The surface tension ({sigma}) values have been further used for the calculation of the surface entropy (S{sup S}) and the surface enthalpy (H{sup S}) per unit surface area. The lyophobicity ({beta}) and the surface mole fraction (x{sub 2}{sup S}) of the surfactant component PEN have been also derived using the extended Langmuir model. The results provide information on the molecular interactions between the unlike molecules that take place at the surface and the bulk.

  16. Effects of consolidation temperature, strength and microstructure on fracture toughness of nanostructured ferritic alloys

    International Nuclear Information System (INIS)

    Miao, P.; Odette, G.R.; Yamamoto, T.; Alinger, M.; Hoelzer, D.; Gragg, D.

    2007-01-01

    Fully consolidated nanostructured ferritic alloys (NFAs) were prepared by attritor milling pre-alloyed Fe-14Cr-3W-0.4Ti and 0.3 wt% Y 2 O 3 powders, followed by hot isostatic pressing (HIPing) at 1000 o C or 1150 o C at 200 MPa for 4 h. Transmission electron microscopy (TEM) revealed similar bimodal distributions of fine and coarse ferrite grains in both cases. However, as expected, the alloy microhardness decreased with increasing in HIPing temperature. Three point bend tests on single edge notched specimens, with a nominal root radius ρ = 0.15 mm, were used to measure the notch fracture toughness, K ρ , as a function of test temperature. The K ρ curves were found to be similar for both processing conditions. It appears that the coarser ferrite grains control cleavage fracture, in a way that is independent of alloy strength and HIPing temperature

  17. Johnson Noise Thermometry in the range 505 K to 933 K

    Science.gov (United States)

    Tew, Weston; Labenski, John; Nam, Sae Woo; Benz, Samuel; Dresselhaus, Paul; Martinis, John

    2006-03-01

    The International Temperature Scale of 1990 (ITS-90) is an artifact-based temperature scale, T90, designed to approximate thermodynamic temperature T. The thermodynamic errors of the ITS-90, characterized as the value of T-T90, only recently have been quantified by primary thermodynamic methods. Johnson Noise Thermometry (JNT) is a primary method which can be applied over wide temperature ranges, and NIST is currently using JNT to determine T-T90 in the range 505 K to 933 K, overlapping both acoustic gas-based and radiation-based thermometry. Advances in digital electronics have now made the computationally intensive processing required for JNT viable using noise voltage correlation in the frequency domain. We have also optimized the design of the 5-wire JNT temperature probes to minimize electromagnetic interference and transmission line effects. Statistical uncertainties under 50 μK/K are achievable using relatively modest bandwidths of ˜100 kHz. The NIST JNT system will provide critical data for T-T90 linking together the highly accurate acoustic gas-based data at lower temperatures with the higher-temperature radiation-based data, forming the basis for a new International Temperature Scale with greatly improved thermodynamic accuracy.

  18. Micromechanical properties of C70 single crystals in the temperature range 77-350 K

    International Nuclear Information System (INIS)

    Lubenets, S.V.; Natsik, V.D.; Fomenko, L.S.; Rusakova, A.V.; Natsik, V.D.; Osip'yan, Yu.A.; Orlov, V.I.; Sidorov, N.S.; Izotov, A.N.

    2012-01-01

    Hexagonal single crystals of C 70 up to a size down to 1-2 mm were grown which allowed for the first time to investigate their low-temperature mechanical properties. Morphology, microplasticity anisotropy and the temperature dependence of Vickers microhardness HV (T) of the C 70 crystals in the temperature range 77-350 K involving all known phase transitions have been studied with the aid of optical microscopy and microindentation. The association of the features of HV (T) dependence with orientation phase transformations has been analyzed. It is suggested that anisotropy of microplasticity in the C 70 crystals correlates with the active slip systems.

  19. Densities and volumetric properties of a (xylene + dimethyl sulfoxide) at temperature from (293.15 to 353.15) K

    International Nuclear Information System (INIS)

    Wang Haijun; Liu Wei; Huang Jihou

    2004-01-01

    The densities of (o-xylene, or m-xylene, or p-xylene + dimethyl sulfoxide) were measured at temperatures (293.15, 303.15, 313.15, 323.15, 333.15, 343.15, 353.15) K and atmospheric pressure by means of a vibrating-tube densimeter. The excess molar volume V m E calculated from the density data provide the temperature dependence of V m E in the temperature range of (293.15 to 353.15) K. The V m E results were correlated using the fourth-order Redlich-Kister equation, with the maximum likelihood principle being applied for the determination of the adjustable parameters. Also we have calculated partial molar volume and excess partial molar volumes of two components. It was found that the V m E in the systems studied increase with rising temperature

  20. 46 CFR 154.1000 - Applicability.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Applicability. 154.1000 Section 154.1000 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CERTAIN BULK DANGEROUS CARGOES SAFETY STANDARDS FOR... § 154.1000 Applicability. Sections 154.1005 through 154.1020 apply to flammable cargo and ammonia...

  1. Validation cases of CATHARE 2 for VVER-1000 main steam line break analysis

    International Nuclear Information System (INIS)

    Kolev, Nikolay P.; Petrov, Nikolay; Donov, Jordan; Sabotinov, Luben; Nikonov, Sergey

    2008-01-01

    Recent coupled code benchmarks identified coolant mixing in the reactor vessel as an unresolved issue in the analysis of complex plan transients with reactivity insertion. Thus, Phase 2 of the OECD VVER-1000 Coolant Transient Benchmark (V1000CT-2) was defined. The benchmark includes calculation of vessel mixing tests and main steam line break (MSLB) analysis. The reference plant is Kozloduy-6 in Bulgaria. The general objective is the assessment of system codes for VVER safety analysis and specifically for their use in the analysis of reactivity transients. A specific objective is the testing of different scale mixing models (mixing matrix, multi-1D, coarse-3D and CFD), and analysis of MSLB transients with improved vessel thermal hydraulic models. The benchmark is sponsored by CEA-France and OECD and is jointly prepared by CEA and INRNE, in collaboration with the Kozloduy NPP, IRSN and PSU. This paper summarizes CATHARE2 code assessment calculations using multi-1D vessel thermal hydraulics with cross flow. Test cases are the OECD V1000CT-1 pump start-up benchmark and the V1000CT-2 benchmarks. Emphasis is put on vessel mixing aspects. Separate effects in the lower plenum as well as component and integral system tests are considered. The comparison shows that a six-sector vessel mixing model informed by plant data or validated CFD calculations in the initial state was able to correctly reproduce the channel average temperatures at the core inlet as well as the vessel outlet temperatures. Testing at system level including code-to-experiment and CATHARE-ATHLET comparison shows that the considered CATHARE VVER-1000 system model is capable of MSLB simulation. (author)

  2. Solid strong base K-Pt/NaY zeolite nano-catalytic system for completed elimination of formaldehyde at room temperature

    Science.gov (United States)

    Song, Shaoqing; Wu, Xi; Lu, Changhai; Wen, Meicheng; Le, Zhanggao; Jiang, Shujuan

    2018-06-01

    Solid strong base nano-catalytic system of K-modification NaY zeolite supported 0.08% Pt (K-Pt/NaY) were constructed for eliminating HCHO at room temperature. In the catalytic process, activation energy over K-Pt/NaY nano-catalytic system was greatly decreased along with the enhanced reaction rate. Characterization and catalytic tests revealed the surface electron structure of K-Pt/NaY was improved, as reflected by the enhanced HCHO adsorption capability, high sbnd OH concentration, and low-temperature reducibility. Therefore, the optimal K-Pt/NaY showed high catalytic efficiency and strong H2O tolerance for HCHO elimination by directly promoting the reaction between active sbnd OH and formate species. These results may suggest a new way for probing the advanced solid strong base nano-catalytic system for the catalytic elimination of indoor HCHO.

  3. Structural investigation on K3Gd5(PO4)6 in between 20 K to 1073 K

    International Nuclear Information System (INIS)

    Bevara, Samatha; Achary, S.N.; Tyagi, A.K.; Mishra, K.K.; Ravindran, T.R.; Sinha, A.K.; Sastry, P.U.

    2016-01-01

    Evolution of crystal structure of K 3 Gd 5 (PO 4 ) 6 in the temperature range from 20 K to 1073 K, as observed from combined variable temperature X-ray diffraction (using both synchrotron source and Cu K α lab source) and Raman spectroscopic studies is communicated in the manuscript. The title compound has an open tunnel containing three dimensional structure built by periodic arrangements of (Gd 5 (PO 4 ) 6 ) 3- ions which in turn are formed by PO 4 tetrahedra and GdO n (n = 8 and 9) polyhedra and these tunnels are occupied by K + ions. The XRD patterns in the entire temperature range of study indicated no change in the crystal structural, which is also supported by differential thermal analyses and Raman spectroscopy. Average axial thermal expansion coefficients between 20K and 1073 K are : α a =10.6 x 10 -6 K -1 , α b = 5.5 x 10 -6 K -1 and α c = 16.4 X 10.6 -6 K -1 . (author)

  4. 29 CFR 98.1000 - Respondent.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 1 2010-07-01 2010-07-01 true Respondent. 98.1000 Section 98.1000 Labor Office of the Secretary of Labor GOVERNMENTWIDE DEBARMENT AND SUSPENSION (NONPROCUREMENT) Definitions § 98.1000 Respondent. Respondent means a person against whom an agency has initiated a debarment or suspension action. ...

  5. 33 CFR 151.1000 - Purpose.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Purpose. 151.1000 Section 151.1000 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) POLLUTION... Transportation of Municipal and Commercial Waste § 151.1000 Purpose. The purpose of this subpart is to implement...

  6. PEGylated DX-1000: Pharmacokinetics and Antineoplastic Activity of a Specific Plasmin Inhibitor

    Directory of Open Access Journals (Sweden)

    Laetitia Devy

    2007-11-01

    Full Text Available Novel inhibitors of the urokinase-mediated plasminogen (plg activation system are potentially of great clinical benefit as anticancer treatments. Using phage display, we identified DX-1000 a tissue factor pathway inhibitor-derived Kunitz domain protein which is a specific high-affinity inhibitor of plasmin (pin (Ki = 99 pM. When tested in vitro, DX-1000 blocks plasminmediated pro-matrix metal loproteinase-9 (proMMP-9 activation on cells and dose-dependently inhibits tube formation, while not significantly affecting hemostasis and coagulation. However, this low-molecular weight protein inhibitor (~ 7 kDa exhibits rapid plasma clearance in mice and rabbits, limiting its potential clinical use in chronic diseases. After site-specific PEGylation, DX-1000 retains its activity and exhibits a decreased plasma clearance. This PEGylated derivative is effective in vitro, as well as potent in inhibiting tumor growth of green fluorescent protein (GFP-labeled MDA-MB-231 cells. 4PEG-DX-1000 treatment causes a significant reduction of urokinase-type plasminogen activator (uPA and plasminogen expressions, a reduction of tumor proliferation, and vascularization. 4PEG-DX-1000 treatment significantly decreases the level of active mitogenactivated protein kinase (MAPK in the primary tumors and reduces metastasis incidence. Together, our results demonstrate the potential value of plasmin inhibitors as therapeutic agents for blocking breast cancer growth and metastasis.

  7. Simultaneous measurements of temperature and density in air flows using UV laser spectroscopy

    Science.gov (United States)

    Fletcher, D. G.; Mckenzie, R. L.

    1991-01-01

    The simultaneous measurement of temperature and density using laser-induced fluorescence of oxygen in combination with Q-branch Raman scattering of nitrogen and oxygen is demonstrated in a low-speed air flow. The lowest density and temperature measured in the experiment correspond to the freestream values at Mach 5 in the Ames 3.5-Foot Hypersonic Wind Tunnel for stagnation conditions of 100 atm and 1000 K. The experimental results demonstrate the viability of the optical technique for measurements that support the study of compressible turbulence and the validation of numerical codes in supersonic and hypersonic wind tunnel flows.

  8. Low-temperature synthesis and structural properties of ferroelectric K 3WO 3F 3 elpasolite

    Science.gov (United States)

    Atuchin, V. V.; Gavrilova, T. A.; Kesler, V. G.; Molokeev, M. S.; Aleksandrov, K. S.

    2010-06-01

    Low-temperature ferroelectric G2 polymorph of K 3WO 3F 3 has been prepared by chemical synthesis. Structural and chemical properties of the final product have been evaluated with X-ray powder diffraction (XRD), scanning electron microscopy (SEM) and X-ray photoelectron spectroscopy (XPS). Structure parameters of G2-K 3WO 3F 3 are refined by the Rietveld method from XRD data measured at room temperature (space group Cm, Z = 2, a = 8.7350(3) Å, b = 8.6808(5) Å, c = 6.1581(3) Å, β = 135.124(3) Å, V = 329.46(3) Å 3; RB = 2.47%). Partial ordering of oxygen and fluorine atoms has been found over anion positions. Mechanism of ferroelectric phase transition in A 2BMO 3F 3 oxyfluorides is discussed.

  9. 21 CFR 1000.1 - General.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false General. 1000.1 Section 1000.1 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) RADIOLOGICAL HEALTH GENERAL General Provisions § 1000.1 General. References in this subchapter J to regulatory sections of the...

  10. The density of molten indium at temperatures up to 600 K

    International Nuclear Information System (INIS)

    Alchagirov, B.B.; Khatsukov, A.M.; Mozgovoj, A.G.

    2004-01-01

    The liquid indium density measurement is carried out through the pycnometric method within the temperature range of 434-600 K both by heating and cooling. The totality of the obtained results was processed through the approximating equation. The root-mean-square deviation of the experimental data from the approximating equation does not exceed ±0.01%. The high accuracy of the obtained results is noted. The deviation of the existing data on the liquid indium density from the approximating equation is shown graphically [ru

  11. Maglev system concept using 20-K high-temperature superconductors and hyperconductors

    Science.gov (United States)

    Hull, J. R.; He, Jianliang

    A magnetically levitated high-speed ground transportation concept is proposed that uses high-temperature superconductors or hyperconductors, cooled by liquid hydrogen at 20 K, to provide levitation. An on-board hydrogen-powered turbine/generator provides electricity for propulsion by linear induction motors. The liquid hydrogen is used to cool the superconductors and the windings of the generator and motors before combusting in the turbine. The principal advantage of this system is the potential to greatly reduce the cost of the guideway, which is completely passive.

  12. 25 CFR 1000.1 - Authority.

    Science.gov (United States)

    2010-04-01

    ... 25 Indians 2 2010-04-01 2010-04-01 false Authority. 1000.1 Section 1000.1 Indians OFFICE OF THE ASSISTANT SECRETARY, INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR ANNUAL FUNDING AGREEMENTS UNDER THE TRIBAL... § 1000.1 Authority. This part is prepared and issued by the Secretary of the Interior under the...

  13. SO2 influence on the K/La2O3 soot combustion catalyst deactivation

    International Nuclear Information System (INIS)

    Peralta, M.A.; Ulla, M.A.; Querini, C.A.

    2008-01-01

    In the present work, K/La 2 O 3 was prepared and tested as a potential catalyst to be used in a diesel engine exhaust. The soot combustion activity was evaluated by temperature-programmed-oxidation (TPO), and the NO x -catalyst interaction was studied using a microbalance experiment. The SO 2 poisoning process and the regeneration of a poisoned K/La 2 O 3 catalyst were analyzed. The fresh catalyst presented a good soot combustion activity. After being treated with a 1000 ppm SO 2 stream, the catalyst was poisoned due to lanthanum sulfate and potassium sulfate formation. The NO x treatment contributed to the K 2 (SO 4 ) decomposition at the expense of extra La 2 (SO 4 ) 3 formation and the H 2 treatment contributed to the La 2 (SO 4 ) 3 decomposition. (author)

  14. Gas phase kinetics of the OH + CH3CH2OH reaction at temperatures of the interstellar medium (T = 21-10^7 K)

    Science.gov (United States)

    Ocaña, A. J.; Blázquez, S.; Ballesteros, B.; Canosa, A.; Antiñolo, M.; Albaladejoab, J.; Jiménez, E.

    2018-02-01

    Ethanol, CH3CH2OH, has been unveiled in the interstellar medium (ISM) by radioastronomy and it is thought to be released into the gas phase after the warm-up phase of the grain surface, where it is formed. Once in the gas phase, it can be destroyed by different reactions with atomic and radical species, such as hydroxyl (OH) radicals. The knowledge of the rate coefficients of all these processes at temperatures of the ISM is essential in the accurate interpretation of the observed abundances. In this work, we have determined the rate coefficient for the reaction of OH with CH3CH2OH (k(T)) between 21 and 10^7 K by employing the pulsed and continuous CRESU (Cinétique de Réaction en Ecoulement Supersonique Uniforme, which means Reaction Kinetics in a Uniform Supersonic Flow) technique. The pulsed laser photolysis technique was used for generating OH radicals, whose time evolution was monitored by laser induced fluorescence. An increase of approximately 4 times was observed for k(21 K) with respect to k(10^7 K). With respect to k(300 K), the OH-reactivity at 21 K is enhanced by two orders of magnitude. The obtained T-expression in the investigated temperature range is k(T) = (2.1 ± 0.5) × 10^-11 (T/300 K)-(0.71±0.10) cm^3 molecule^-1 s^-1. In addition, the pressure dependence of k(T) has been investigated at several temperatures between 21 K and 90 K. No pressure dependence of k(T) was observed in the investigated ranges. This may imply that this reaction is purely bimolecular or that the high-pressure limit is reached at the lowest total pressure experimentally accessible in our system. From our results, k(T) at usual IS temperatures (˜10-100 K) is confirmed to be very fast. Typical rate coefficients can be considered to range within about 4 × 10^-11 cm^3 molecule^-1 s^-1 at 100 K and around 1 × 10^-10 cm^3 molecule^-1 s^-1 at 20 K. The extrapolation of k at the lowest temperatures of the dense molecular clouds of ISM is also discussed in this paper.

  15. Oxidation of Zircaloy-4 under limited steam supply at 1000 and 13000C

    International Nuclear Information System (INIS)

    Uetsuka, H.

    1984-12-01

    With the view of examining the oxidation behavior of Zircaloy-4 under limited steam supply occurring in severe accidents of LWRs, Zircaloy-4 cladding specimens were examined at the isothermal oxidation temperatures of 1000 and 1300 0 C under a steam atmosphere, flowing at a reduced and constant rate in the range of 3proportional170 mg/cm 2 xmin. The effect of steam starvation, which was restricted to very low levels of steam supply rate, was observed at the two examined temperatures. And the critical supply rate of steam starvation was evaluated to be 13 and 20 mg/cm 2 xmin for the oxidation at 1000 and 1300 0 C, respectively. Variation of the oxidation duration between 2 and 60 min at 1000 0 C allowed to compare the reaction kinetics for three different rates of steam supply. The short-term results confirmed the reduced reaction rates for the lower steam supplies. At the longer times, however, a clear trend towards linear kinetics was observed for the lower supplies. This can be interpreted as the result of earlier breakaway transition under limited steam supply. In the test at 1300 0 C, an acceleration of the oxidation rate was measured for the specified steam supply rate between 20 and 60 mg/cm 2 xmin. This related strongly with high hydrogen concentration in the atmosphere. Hydrogen blanketing - the retarding effect of hydrogen on Zircaloy oxidation - was not identified in the examined temperature range. (orig./HP) [de

  16. dK/da effects on the SCC growth rates of nickel base alloys in high-temperature water

    Science.gov (United States)

    Chen, Kai; Wang, Jiamei; Du, Donghai; Andresen, Peter L.; Zhang, Lefu

    2018-05-01

    The effect of dK/da on crack growth behavior of nickel base alloys has been studied by conducting stress corrosion cracking tests under positive and negative dK/da loading conditions on Alloys 690, 600 and X-750 in high temperature water. Results indicate that positive dK/da accelerates the SCC growth rates, and the accelerating effect increases with dK/da and the initial CGR. The FRI model was found to underestimate the dK/da effect by ∼100X, especially for strain hardening materials, and this underscores the need for improved insight and models for crack tip strain rate. The effect of crack tip strain rate and dK/dt in particular can explain the dK/da accelerating effect.

  17. 21 CFR 573.1000 - Verxite.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Verxite. 573.1000 Section 573.1000 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL DRUGS, FEEDS... Listing § 573.1000 Verxite. The food additive verxite may be safely used in animal feed in accordance with...

  18. 25 CFR 11.1000 - Complaint.

    Science.gov (United States)

    2010-04-01

    ... 25 Indians 1 2010-04-01 2010-04-01 false Complaint. 11.1000 Section 11.1000 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR LAW AND ORDER COURTS OF INDIAN OFFENSES AND LAW AND ORDER CODE Juvenile Offender Procedure § 11.1000 Complaint. A complaint must be filed by a law enforcement officer or...

  19. Optimization of advanced high-temperature Brayton cycles with multiple reheat stages

    International Nuclear Information System (INIS)

    Haihua Zhao; Per F Peterson

    2005-01-01

    Full text of publication follows: This paper presents an overview and a few point designs for multiple-reheat Brayton cycle power conversion systems using high temperature molten salts (or liquid metals). All designs are derived from the General Atomics GT-MHR power conversion unit (PCU). The GT-MHR PCU is currently the only closed helium cycle system that has undergone detailed engineering design analysis, and that has turbomachinery which is sufficiently large to extrapolate to a >1000 MW(e) multiple reheat gas cycle power conversion system. Analysis shows that, with relatively small engineering modifications, multiple GT-MHR PCU's can be connected together to create a power conversion system in the >1000 MW(e) class. The resulting power conversion system is quite compact, and results in what is likely the minimum gas duct volume possible for a multiple-reheat system. To realize this, compact offset fin plate type liquid-to-gas heat exchangers (power densities from 10 to 120 MW/m 3 ) are needed. Both metal and non-metal heat exchangers are being investigated for high-temperature, gas-cooled reactors for temperatures to 1000 deg. C. Recent high temperature heat exchanger studies for nuclear hydrogen production has suggested that carbon-coated composite materials such as liquid silicon infiltrated chopped fiber carbon-carbon preformed material potentially could be used to fabricate plate fin heat exchangers with reasonable price. Different fluids such as helium, nitrogen and helium mixture, and supercritical CO 2 are compared for these multiple reheat Brayton cycles. Nitrogen and helium mixture cycle need about 40% more total PCU volume than helium cycle while keeping the same net cycle efficiency. Supercritical CO 2 needs very high pressure to optimize. Due to relatively detailed design for components such as heat exchangers, turbomachinery, and duct system, relatively accurate total pressure loss can be obtained, which results in more credible net efficiency

  20. Development of 350 MHz/1000 Watt intermediate power amplifier for 400 keV RFQ accelerator

    International Nuclear Information System (INIS)

    Pande, M.M.; Patel, N.R.; Shinde, K.R.; Rao, M.K.V.; Handu, V.K.

    2005-01-01

    Two numbers of high power RF systems, each delivering around 35 to 40 kW of power at 350 MHz are being developed in BARC. These High Power Amplifiers (HPA) cater to the total need of 70 kW of RF power required by the 400 keV (Deuterium) RFQ accelerator. This RFQ will replace the existing 400 keV DC accelerator of 14 MeV Neutron Generator. The RFQ will accelerate a deuterium beam from 50 keV to 400 keV to impinge upon a tritium target inside a sub critical assembly. Each of these 35 / 40 KW HPA requires a drive power of around 1000 / 1500 Watt respectively. Hence a intermediate power amplifier (IPA) bas been designed to deliver the power of 1000 Watt at the rate of 350 MHz. The paper describes the development of this amplifier

  1. Melting-pressure and density equations of 3He at temperatures from 0.001 to 30 K

    International Nuclear Information System (INIS)

    Huang Yonghua; Chen Guobang

    2005-01-01

    Nonsegmented equations for melting pressure and density at temperatures from 0.001 K to 30 K have been developed to fit the reference data. The maximum and average deviations between the melting pressure equation and the totaling 298 reference data are 2.17% and 0.218%, respectively. For the density equations, the average deviations are 0.236% for the liquid side and 0.218% for the solid side. Both the melting pressure curve and melting density curves predicted by the submitted equations approach their minimums at about 0.315 K

  2. Comparison of optical spectra recorded during DPF-1000U plasma experiments with gas-puffing

    Directory of Open Access Journals (Sweden)

    Zaloga Dobromil R.

    2015-06-01

    Full Text Available The results are presented of the optical spectra measurements for free plasma streams generated with the use of the modified DPF-1000U machine. This facility was recently equipped with a gas injection system (the so-called gas-puff placed on the symmetry axis behind the central opening in the inner electrode. The DPF-1000U experimental chamber was filled up with pure deuterium at the initial pressure of 1.6 or 2.4 mbar. Additionally, when the use was made of the gas-puff system about 1 cm3 of pure deuterium was injected at the pressure of 2 bars. The gas injection was initiated 1.5 or 2 ms before the triggering of the main discharge. The investigated plasma discharges were powered from a condenser bank charged initially to 23 kV (corresponding to the energy of 352 kJ, and the maximum discharge current amounted to about 1.8 MA. In order to investigate properties of a dense plasma column formed during DPF-1000U discharges the use was made of the optical emission spectroscopy. The optical spectra were recorded along the line of sight perpendicular to the vacuum chamber, using a Mechelle®900 spectrometer. The recent analysis of all the recorded spectra made it possible to compare the temporal changes in the electron density of a freely propagating plasma stream for discharges without and with the gas-puffing. Using this data an appropriate mode of operation of the DPF-1000U facility could be determined.

  3. Soot measurements for diesel and biodiesel spray combustion under high temperature highly diluted ambient conditions

    KAUST Repository

    Zhang, Ji

    2014-11-01

    This paper presents the soot temperature and KL factor for biodiesel, namely fatty acid methyl ester (FAME) and diesel fuel combustion in a constant volume chamber using a two-color technique. The KL factor is a parameter for soot concentration, where K is an absorption coefficient and proportional to the number density of soot particles, L is the geometric thickness of the flame along the optical detection axis, and KL factor is proportional to soot volume fraction. The main objective is to explore a combustion regime called high-temperature and highly-diluted combustion (HTHDC) and compare it with the conventional and low-temperature combustion (LTC) modes. The three different combustion regimes are implemented under different ambient temperatures (800 K, 1000 K, and 1400 K) and ambient oxygen concentrations (10%, 15%, and 21%). Results are presented in terms of soot temperature and KL factor images, time-resolved pixel-averaged soot temperature, KL factor, and spatially integrated KL factor over the soot area. The time-averaged results for these three regimes are compared for both diesel and biodiesel fuels. Results show complex combined effects of the ambient temperature and oxygen concentration, and that two-color temperature for the HTHDC mode at the 10% oxygen level can actually be lower than the conventional mode. Increasing ambient oxygen and temperature increases soot temperature. Diesel fuel results in higher soot temperature than biodiesel for all three regimes. Results also show that diesel and biodiesel fuels have very different burning and sooting behavior under the three different combustion regimes. For diesel fuel, the HTHDC regime offers better results in terms of lower soot than the conventional and LTC regimes, and the 10% O2, 1400 K ambient condition shows the lowest soot concentration while maintaining a moderate two-color temperature. For biodiesel, the 15% O2, 800 K ambient condition shows some advantages in terms of reducing soot

  4. 30 CFR 250.1000 - General requirements.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 2 2010-07-01 2010-07-01 false General requirements. 250.1000 Section 250.1000... OPERATIONS IN THE OUTER CONTINENTAL SHELF Pipelines and Pipeline Rights-of-Way § 250.1000 General....1001, must meet the requirements in §§ 250.1000 through 250.1008. (2) A pipeline right-of-way grant...

  5. 7 CFR 1000.54 - Equivalent price.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 9 2010-01-01 2009-01-01 true Equivalent price. 1000.54 Section 1000.54 Agriculture... Prices § 1000.54 Equivalent price. If for any reason a price or pricing constituent required for computing the prices described in § 1000.50 is not available, the market administrator shall use a price or...

  6. Temperature-dependent structure evolution in liquid gallium

    International Nuclear Information System (INIS)

    Xiong, L.H.; Wang, X.D.; Yu, Q.; Zhang, H.; Zhang, F.; Sun, Y.; Cao, Q.P.; Xie, H.L.; Xiao, T.Q.; Zhang, D.X.; Wang, C.Z.; Ho, K.M.

    2017-01-01

    Temperature-dependent atomistic structure evolution of liquid gallium (Ga) has been investigated by using in situ high energy X-ray diffraction experiment and ab initio molecular dynamics simulation. Both experimental and theoretical results reveal the existence of a liquid structural change around 1000 K in liquid Ga. Below and above this temperature the liquid exhibits differences in activation energy for self-diffusion, temperature-dependent heat capacity, coordination numbers, density, viscosity, electric resistivity and thermoelectric power, which are reflected from structural changes of the bond-orientational order parameter Q_6, fraction of covalent dimers, averaged string length and local atomic packing. This finding will trigger more studies on the liquid-to-liquid crossover in metallic melts. - Graphical abstract: Atomistic structure evolution of liquid gallium has been investigated by using in situ high energy X-ray diffraction and ab initio molecular dynamics simulations, which both demonstrate the existence of a liquid structural change together with reported density, viscosity, electric resistivity and absolute thermoelectric power data.

  7. X-ray diffraction studies on K3Gd5 (PO4) 6 between 20K to 1073 K

    International Nuclear Information System (INIS)

    Bevara, Samatha; Achary, S.N.; Tyagi, A.K.; Sinha, A.K.; Sastry, P.U.

    2016-01-01

    Complex inorganic phosphates have been of interest due to their diversified crystal chemistry depending on composition, preparation condition as well as external parameters like temperature and pressure. In addition varieties of complex phosphates have been considered as potential host matrices for immobilization of radioactive elements as well as for selective separation of ions from high level nuclear waste or heavy metal ion pollutants from environment. Temperature and/or pressure induced structural variations are often noticed in such type complex phosphates. In K 2 O-Gd 2 O 3 -P 2 O 5 , a novel complex phosphate with K 3 Gd 5 (PO 4 ) 6 has been reported recently. In order to study the effect of temperature on crystal structure of K 3 Gd 5 (PO 4 ) 6 variable temperature XRD studies between 20 K to 1073 K were carried out and the results are presented herein

  8. 24 CFR 1000.28 - May a self-governance Indian tribe be exempted from the applicability of § 1000.26?

    Science.gov (United States)

    2010-04-01

    ... be exempted from the applicability of § 1000.26? 1000.28 Section 1000.28 Housing and Urban... ACTIVITIES General § 1000.28 May a self-governance Indian tribe be exempted from the applicability of § 1000... and systems meet or exceed the comparable requirements of § 1000.26. For purposes of this section, a...

  9. Corium Oxidation at Temperatures Above 2000 K

    International Nuclear Information System (INIS)

    Hagrman, Donald L.; Rempe, Joy L.

    2001-01-01

    A mechanistic model, based on a quasi-equilibrium analysis of oxidation reactions, is proposed for predicting high-temperature corium oxidation. The analysis suggests that oxide forming on the surface of corium containing uranium, zirconium, and iron is similar to the oxides formed on zirconium and uranium as long as there is a small percentage of unoxidized zirconium or uranium in the metallic phase. This is because of the higher affinity of zirconium and uranium for oxygen. Hence, oxidation rates and heat production rates are similar to (U,Zr) compounds until nearly all the uranium and zirconium in the corium oxidizes. Oxidation rates after this point are predicted to be similar to those implied by the oxide thickness present when the forming oxide ceases to be protective, and heat generation rates should be similar to those implied by iron oxidation, i.e., ∼4% of the zirconium oxidation heating rate.The maximum atomic ratio of unoxidized iron to unoxidized liquid zirconium plus uranium for the formation of a solid protective oxide below 2800 K is estimated for a temperature, T (in Kelvin), as follows:(unoxidized iron)/(unoxidized zirconium + turanium) = (1/28){5.7/exp[-(147 061 + 12.08T log(T) - 61.03T - 0.000555T 2 /1.986T)]} 1/2 .As long as this limit is not exceeded, either zirconium or uranium metal oxidation rates and heating describe the corium oxidation rate. If this limit is exceeded, diffusion of steam to the corium surface will limit the oxidation rate, and linear time-dependent growth of a nonprotective, mostly FeO, layer will occur below the protective (Zr,U) O 2 scale. When this happens, the oxidation should be at the constant rate given by the thickness of the protective layer. Heat generation should be similar to that of iron oxidation

  10. Corium Oxidation at Temperatures Above 2000 K

    Energy Technology Data Exchange (ETDEWEB)

    Hagrman, Donald Lee; Rempe, Joy Lynn

    2001-02-01

    A mechanistic model, based on a quasi-equilibrium analysis of oxidation reactions, is proposed for predicting high-temperature corium oxidation. The analysis suggests that oxide forming on the surface of corium containing uranium, zirconium, and iron is similar to the oxides formed on zirconium and uranium as long as there is a small percentage of unoxidized zirconium or uranium in the metallic phase. This is because of the higher affinity of zirconium and uranium for oxygen. Hence, oxidation rates and heat production rates are similar to (U,Zr) compounds until nearly all the uranium and zirconium in the corium oxidizes. Oxidation rates after this point are predicted to be similar to those implied by the oxide thickness present when the forming oxide ceases to be protective, and heat generation rates should be similar to those implied by iron oxidation, i.e., ~4% of the zirconium oxidation heating rate. The maximum atomic ratio of unoxidized iron to unoxidized liquid zirconium plus uranium for the formation of a solid protective oxide below 2800 K is estimated for a temperature, T (in Kelvin), as follows: (unoxidized iron)/(unoxidized zirconium + turanium) = (1/28){5.7/exp[-(147 061 + 12.08T log(T) - 61.03T - 0.000555T2/1.986T)]}1/2. As long as this limit is not exceeded, either zirconium or uranium metal oxidation rates and heating describe the corium oxidation rate. If this limit is exceeded, diffusion of steam to the corium surface will limit the oxidation rate, and linear time-dependent growth of a nonprotective, mostly FeO, layer will occur below the protective (Zr,U) O2 scale. When this happens, the oxidation should be at the constant rate given by the thickness of the protective layer. Heat generation should be similar to that of iron oxidation.

  11. Fatigue-induced dislocation structure of titanium alloy VT5-1ct at temperatures of 293-11 K

    Energy Technology Data Exchange (ETDEWEB)

    Grinberg, N.M. (Inst. for Low Temperature Physics and Engineering, Ukrainian Academy of Sciences, Kharkov (Ukraine)); Aleksenko, E.N. (Inst. for Low Temperature Physics and Engineering, Ukrainian Academy of Sciences, Kharkov (Ukraine)); Moskalenko, V.A. (Inst. for Low Temperature Physics and Engineering, Ukrainian Academy of Sciences, Kharkov (Ukraine)); Smirnov, A.R.N. (Inst. for Low Temperature Physics and Engineering, Ukrainian Academy of Sciences, Kharkov (Ukraine)); Yakovenko, L.F. (Inst. for Low Temperature Physics and Engineering, Ukrainian Academy of Sciences, Kharkov (Ukraine)); Mozhaev, A.V. (Inst. for Low Temperature Physics and Engineering, Ukrainian Academy of Sciences, Kharkov (Ukraine)); Arinushkin, I.A. (Inst. for Low Temperature Physics and Engineering, Ukrainian Academy of Sciences, Kharkov (Ukraine))

    1993-07-05

    The dislocation structure formed during the final stage of fatigue at high- and low-amplitude stresses at T=293 K in air and T=293, 93 and 11 K in high vacuum is studied on the Ti alloy VT5-1ct which has been prepared by two processing methods. The [sigma]-N curves are plotted for corresponding experimental conditions. It is shown that slip alone is responsible for the plastic deformation. The characteristic features of the dislocation structure formed are reported. The morphology of the a phase does not influence the character of the dislocation structure. At lower temperatures, the substructure remains practically unaltered, although the likelihood of uniformly distributed dislocations is lower. The lifetime is essentially dependent on the environment, temperature and the alloy microstructure, the latter being especially important at low temperatures in the high-amplitude region. (orig.)

  12. Irradiation of TZM: Uranium dioxide fuel pin at 1700 K

    Science.gov (United States)

    Mcdonald, G. E.

    1973-01-01

    A fuel pin clad with TZM and containing solid pellets of uranium dioxide was fission heated in a static helium-cooled capsule at a maximum surface temperature of 1700 K for approximately 1000 hr and to a total burnup of 2.0 percent of the uranium-235. The results of the postirradiation examination indicated: (1) A transverse, intergranular failure of the fuel pin occurred when the fuel pin reached 2.0-percent burnup. This corresponds to 1330 kW-hr/cu cm, where the volume is the sum of the fuel, clad, and void volumes in the fuel region. (2) The maximum swelling of the fuel pin was less than 1.5 percent on the fuel-pin diameter. (3) There was no visible interaction between the TZM clad and the UO2. (4) Irradiation at 1700 K produced a course-grained structure, with an average grain diameter of 0.02 centimeter and with some of the grains extending one-half of the thickness of the clad. (5) Below approximately 1500 K, the irradiation of the clad produced a moderately fine-grained structure, with an average grain diameter of 0.004 centimeter.

  13. High Temperature Elastic Properties of Reduced Activation Ferritic-Martensitic (RAFM) Steel Using Impulse Excitation Technique

    Science.gov (United States)

    Tripathy, Haraprasanna; Raju, Subramanian; Hajra, Raj Narayan; Saibaba, Saroja

    2018-03-01

    The polycrystalline elastic constants of an indigenous variant of 9Cr-1W-based reduced activation ferritic-martensitic (RAFM) steel have been determined as a function of temperature from 298 K to 1323 K (25 °C to 1000 °C), using impulse excitation technique (IET). The three elastic constants namely, Young's modulus E, shear modulus G, and bulk modulus B, exhibited significant softening with increasing temperature, in a pronounced non-linear fashion. In addition, clearly marked discontinuities in their temperature variations are noticed in the region, where ferrite + carbides → austenite phase transformation occurred upon heating. Further, the incidence of austenite → martensite transformation upon cooling has also been marked by a step-like jump in both elastic E and shear moduli G. The martensite start M s and M f finish temperatures estimated from this study are, M s = 652 K (379 °C) and M f =580 K (307 °C). Similarly, the measured ferrite + carbide → austenite transformation onset ( Ac 1) and completion ( Ac 3) temperatures are found to be 1126 K and 1143 K (853 °C and 870 °C), respectively. The Poisson ratio μ exhibited distinct discontinuities at phase transformation temperatures; but however, is found to vary in the range 0.27 to 0.29. The room temperature estimates of E, G, and μ for normalized and tempered microstructure are found to be 219 GPa, 86.65 GPa, and 0.27, respectively. For the metastable austenite phase, the corresponding values are: 197 GPa, 76.5 GPa, and 0.29, respectively. The measured elastic properties as well as their temperature dependencies are found to be in good accord with reported estimates for other 9Cr-based ferritic-martensitic steel grades. Estimates of θ D el , the elastic Debye temperature and γ G, the thermal Grüneisen parameter obtained from measured bulk elastic properties are found to be θ D el = 465 K (192 °C) and γ G = 1.57.

  14. Investigation of the Effective Thermal Conductivity in Containment Wall of OPR1000

    Energy Technology Data Exchange (ETDEWEB)

    Noh, Hyung Gyun [Pohang University, Pohang (Korea, Republic of); Lee, Jong Hwi; Kang, Hie Chan [Kunsan National University, Gunsan (Korea, Republic of)

    2016-05-15

    Many computational codes used for analyzing pressure of containment was developed such as CAP (Containment Analysis Package). These computational codes consider concrete conductivity instead of thermal conductivity of containment wall which have special geometry as heat sink. For precise analysis, effective thermal conductivity of containment wall has to be measured in individual NPPs. Thermal properties of concrete such as thermal conductivity have been investigated as function of chemical composition and temperature. Generally, containment of OPR1000 is constructed by Prestressed (PS) concrete-a composite material. Containment wall of OPR1000 is made up of steel liner, tendon, rebar and concrete as shown in Figure 1. Role of steel liner protects release of radioactive materials so called leak tightness. The effective thermal conductivity of containment wall in OPR1000 is analyzed by numerical tool (CFD) and compared with thermal conductivity models in composite solids. The effective thermal conductivity of containment wall of OPR1000 is investigated by numerical analysis (CFD). The thermal conductivity of reinforced concrete is 18.6% higher than that of concrete only. Several models were compared with CFD results. Rayleigh-Parallel liner model agrees well with CFD results. Experiment results will be compared with CFD result and models. CFD result was calculated in low steel volume fraction (0.0809) than that of OPR1000 (0.1043). The effective thermal conductivity in OPR1000 has slightly higher than CFD result because of different volume fraction.

  15. NRC Microwave Refractive Index Gas Thermometry Implementation Between 24.5 K and 84 K

    Science.gov (United States)

    Rourke, P. M. C.

    2017-07-01

    The implementation of microwave refractive index gas thermometry at the National Research Council between 24.5 K and 84 K is reported. A new gas-handling system for accurate control and measurement of experimental gas pressure has been constructed, and primary thermometry measurements have been taken using a quasi-spherical copper resonator and helium gas at temperatures corresponding to three defining fixed points of the International Temperature Scale of 1990 (ITS-90). These measurements indicate differences between the thermodynamic temperature T and ITS-90 temperature T_{90} of ( T - T_{90} ) = -0.60 ± 0.56 mK at T_{90} = 24.5561 K, ( T - T_{90} ) = -2.0 ± 1.3 mK at T_{90} = 54.3584 K, and ( T - T_{90} ) = -4.0 ± 2.9 mK at T_{90} = 83.8058 K. The present results at T_{90} = 24.5561 K and T_{90} = 83.8058 K agree with previously reported measurements from other primary thermometry techniques of acoustic gas thermometry and dielectric constant gas thermometry, and the result at T_{90} = 54.3584 K provides new information in a temperature region where there is a gap in other recent data sets.

  16. AP1000. The PWR revisited

    International Nuclear Information System (INIS)

    Gaio, P.

    2006-01-01

    The distinguishing features of Westinghouse's AP1000 advanced passive pressurized water reactor are highlighted. In particular, the AP1000's passive safety features are described as well as their implications for simplifying the design, construction, and operation of this design compared to currently operating plants, and significantly increasing safety margins over current plants as well. The AP1000 design specifically incorporates the knowledge acquired from the substantial accumulation of power reactor operating experience and benefits from the application of the Probabilistic Risk Assessment in the design process itself. The AP1000 design has been certified by the US Nuclear Regulatory Commission under its new rules for licensing new nuclear plants, 10 CFR Part 52, and is the subject of six combined Construction and Operating License applications now being developed. Currently the AP1000 design is being assessed against the EUR Rev C requirements for new nuclear power plants in Europe. (author)

  17. Temperature Measurements Using Type K Thermocouples and the Fluke Helios Plus 2287A Datalogger

    DEFF Research Database (Denmark)

    Artmann, Nikolai; Vonbank, R.; Jensen, Rasmus Lund

    the circuit creates a circuit in which the two legs generate different voltages, leaving a small difference in voltage available for measurement (Figure 1). That difference increases with temperature, and can typically be between one and seventy micro-volts per Kelvin (μV/K) for the modern range of available...

  18. Dislocation-mediated trapping of deuterium in tungsten under high-flux high-temperature exposures

    Science.gov (United States)

    Bakaeva, A.; Terentyev, D.; De Temmerman, G.; Lambrinou, K.; Morgan, T. W.; Dubinko, A.; Grigorev, P.; Verbeken, K.; Noterdaeme, J. M.

    2016-10-01

    The effect of severe plastic deformation on the deuterium retention in tungsten exposed to high-flux low-energy plasma (flux ∼1024 m-2 s-1, energy ∼50 eV and fluence up to 5 × 1025 D/m2) was studied experimentally in a wide temperature range (460-1000 K) relevant for application in ITER. The desorption spectra in both reference and plastically-deformed samples were deconvoluted into three contributions associated with the detrapping from dislocations, deuterium-vacancy clusters and pores. As the exposure temperature increases, the positions of the release peaks in the plastically-deformed material remain in the same temperature range but the peak amplitudes are altered as compared to the reference material. The desorption peak attributed to the release from pores (i.e. cavities and bubbles) was suppressed in the plastically deformed samples for the low-temperature exposures, but became dominant for exposures above 700 K. The observed strong modulation of the deuterium storage in "shallow" and "deep" traps, as well as the reduction of the integral retention above 700 K, suggest that the dislocation network changes its role from "trapping sites" to "diffusion channels" above a certain temperature. The major experimental observations of the present work are in line with recent computational assessment based on atomistic and mean field theory calculations available in literature.

  19. Home-made temperature monitoring system from four-channel K-type thermocouples via internet of thing technology platform

    Science.gov (United States)

    Detmod, Thitaporn; Özmen, Yiǧiter; Songkaitiwong, Kittiphot; Saenyot, Khanuengchat; Locharoenrat, Kitsakorn; Lekchaum, Sarai

    2018-06-01

    This paper is aimed to design and construct the home-made temperature monitoring system from four-channel K-type thermocouples in order to improve the temperature measurement based on standard evaluation measurements guidance. The temperature monitoring system was capable to record the temperature on SD card and to display the realtime temperature on Internet of Thing Technology platform. The temperature monitoring system was tested in terms of the temperature measurement accuracy and delay response time. It was found that a standard deviation was acceptable as compared to the Instrument Society of America. The response time of the microcontroller to SD card was 2 sec faster than that of the microcontroller to Thingspeak.

  20. Obtention and characterization of activated carbons from seeds of Macuna sp

    International Nuclear Information System (INIS)

    Vargas, Jaime E; Giraldo, Liliana; Moreno, Juan C

    2008-01-01

    A series of activated carbons from a lignocellulosic material is obtained by a physical activation with water vapor. Mucuna sp is the scientific name of the seed used as a lignoocellulosic precursor. In this work the seeds are crushed and sieved before carbonizing them to obtain granular activated carbon. The effect of temperature (600-900 Celsius degrade) and time of activation (1-10 h) was studied as well as the relationship with the textural properties of the carbon. The activated carbons obtained with different percentages of Burn-off were characterized by physical adsorption of N 2 at 77K. We evaluated the ability of an adsorption in solution of the activated carbons by iodine index and the methylene blue index. We found a correlation between burn-off and the apparent surface area calculated by the BET method with values close to 1000 m 2 g -1 as well as microspore volumes between 0.060 and 0.400 cm 3 g -1 calculated by the DR method and the method alpha. The adsorption capacity in solution gives good results, because the results show good correlation with the porosity data. This is very important when determining the possible applications of the activated carbons

  1. Thermal Stability of Austempered Ductile Iron Evaluated in a Temperature Range of 20-300K

    Directory of Open Access Journals (Sweden)

    Dawid MYSZKA

    2016-05-01

    Full Text Available The aim of this article was to determine through changes in magnetic properties the stability of the austempered ductile iron (ADI microstructure during temperature changes in a range of 20 – 300 K. The measurements were taken in a vibrating sample magnetometer (VSM using Fe27Ni2TiMoAlNb austenitic stainless steel and four types of austempered ductile iron obtained under various heat treatment conditions. The plotted curves showing changes in the magnetisation degree as a function of temperature had a number of characteristic points illustrating changes taking place in the microstructure. For each of the materials examined, the martensite start temperature Ms and the temperature range within which the martensitic transformation takes place were identified.

  2. Thermal properties of KUO3(s) and K2U2O7 - by high temperature Calvet calorimeter

    International Nuclear Information System (INIS)

    Jayanthi, K.; Iyer, V.S.; Venugopal, V.

    1998-01-01

    The thermal properties of KUO 3 (s) and K 2 U 2 O 7 (s) were determined using a high temperature Calvet calorimeter by drop method. The enthalpy increments, (H T o - H 298.15 0 ), in kJ/mol for KUO 3 (s) and K 2 U 2 O 7 (s) can be represented by, H T o - H 298.15 0 KUO 3 (s) kJ/mol ± 0.7 = -39.15 + 0.129T + 0.1005x10 -4 T 2 (369-714K) and H T o -H 298.15 0 K 2 U 2 O 7 (s) kJ/mol ± 0.7 = -52.99 + 0.1361T + 0.146x10 -3 T 2 (391 - 683K). (author)

  3. The enthalpy of solid scandium in the temperature range 406 - 1812 K

    International Nuclear Information System (INIS)

    Lyapunov, K.M.; Baginskij, A.V.; Stankus, S.V.

    2001-01-01

    Enthalpy of pure scandium was measured on massive calorimeter in the range from 406 to 1812 K by mixing method. The enthalpy of face centered close cubic lattice - body centered cubic lattice transformation is equal to ΔH t 4068 J/mol. Obtained value within the limits of error is compatible with the results given earlier (4009 J/mol). The dependence of the middle specific heat of scandium C p (T) on the temperature was shown in correlation with the results of other works. The results of the conducted experiments reinforce the conclusion made earlier about an absence (or a little) in the decomposition of an anharmonic component of the oscillation specific heat of scandium C p a (T) members proportional to the first or the second degrees of temperature [ru

  4. Evidence for a temperature-induced spin-state transition of Co3+ in La2-xSrxCoO4

    Science.gov (United States)

    Hollmann, N.; Haverkort, M. W.; Benomar, M.; Cwik, M.; Braden, M.; Lorenz, T.

    2011-05-01

    We study the magnetic susceptibility of mixed-valent La2-xSrxCoO4 single crystals in the doping range of 0.5⩽x⩽0.8 for temperatures up to 1000 K. The magnetism below room temperature is described by paramagnetic Co2+ in the high-spin state and by Co3+ in the nonmagnetic low-spin state. At high temperatures, an increase in susceptibility is seen, which we attribute to a temperature-induced spin-state transition of Co3+. The susceptibility is analyzed by comparison to full-multiplet calculations for the thermal population of the high- and intermediate-spin states of Co3+.

  5. Low-temperature thermometry. Use of a gas thermometer as a calibration standard between 4 and 300 K

    International Nuclear Information System (INIS)

    Combarieu, A. de

    1978-01-01

    A constant volume gas thermometer was built to calibrate the various secondary thermometers used at low temperature. This gas thermometer is placed in a cryostat where any stable temperature between 4 and 300 K may be obtained. After some words about low temperature thermometry, the gas thermometer and its auxiliary equipment are described briefly; the corrections to be applied to the results are given and the article ends with a table showing the values obtained [fr

  6. Fault of the correction factor for pressure and temperature k{sub PT} in the atmospheric conditions of Dosimetric Calibration Lab. - LSCD of ININ - Mexico; Falla del factor de correcion por presion y temperatura k{sub PT} a las condiciones atmosfericas del LSCD-ININ-Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Alvarez R, Jose T.; Jesus Cejudo, A.; La Cruz H., Daniel de; Tovar M, Victor M., E-mail: trinidad.alvarez@inin.gob.mx, E-mail: jesus.cejudo@inin.gob.mx, E-mail: daniel.delacruz@inin.gob.mx, E-mail: victor.tovar@inin.gob.mx [Instituto Nacional de Investigaciones Nucleares (LSCD/ININ), Ocoyoacac (Mexico). Laboratorio Secundario de Calibracion Dosimetrica

    2013-07-01

    The realization of the operational quantities H*, Hp y/0 H'(0.07) for estimating the effective dose E, usually is done by measuring the air kerma Ka air within the field of ionizing radiation of interest and was subsequently applied appropriate conversion factors for both the quality of radiation and the operational quantity of interest. However, the SSDL in performing the Ka to environmental conditions of ININ (3000 m above sea level, P ∼ 710 hPa) with ionization chambers has found that the pressure correction factor and kPT temperature is not sufficient to correct the change in air density. Indeed, in the case of {sup 60}Co the discrepancy between the measurement of a primary standard graphite walls Ka (BEV CC01 be 131) and a side of the plastic walls (Exradin A12) is on the order of 0.4% for the case of the RX BIPM qualities to 100,135, 180 and 250 kV. It was found that for a camera model 30001 PTW (PMMA graphite wall) is needed an additional correction factor k PT ranging from 0.4% to 1.5%, correction factor calculated by MC simulation. For Sk of {sup 125}I brachytherapy sources was given an additional correction lower in 11% compared to conventional k{sub PT} value measured with a well chamber Standard Imaging HDR 1000 plus. Finally, it is in the process of studying the behavior of this additional correction factor to the case of {sup 137}Cs.

  7. Determinaciones termogravimétricas y de calor específico de un concentrado comercial de ulexita, entre temperatura ambiente y 1.000 ºC

    Directory of Open Access Journals (Sweden)

    Flores, H. R.

    2006-12-01

    Full Text Available The important amount of hydration water in the ulexite (NaCaB5O9.8H2O, allows using calcination methods to increase its B2O3 content. This paper analyses the thermal decomposition reaction of a preconcentrated ulexite through weight loss measurements, which occur during the heating of samples until 1000 ºC. Determinations of heat content at each temperature were made using an isoperibol calorimeter. The mean specific heat was calculated from these values, and its dependence on temperature was determined. The maximum weight loss was about 32.5 % and the specific heat obtained was 1,13 kJ/kgºC for solid samples and 1,38 kJ/kgºC for fluid samples.The results are useful for the design of the industrial process, in order to determine the thermal requirements for heating calcined ulexite, and to obtain smelted ulexite.

    El elevado contenido de agua de hidratación de la ulexita (NaCaB5O9.8H2O permite utilizar la calcinación como método de concentración. En este trabajo se analiza la reacción de descomposición térmica de un preconcentrado de ulexita a través de determinaciones de la pérdida de peso ocurrida durante el calentamiento de la muestra hasta 1000 ºC. Por otra parte, se ha determinado el valor del calor sensible a cada temperatura ensayada mediante un calorímetro tipo isoperibol y se ha calculado el calor específico medio de la muestra calcinada, así como su variación con la temperatura. Se obtuvieron pérdidas de peso de 32,5 % y valores del calor específico de 1,13 kJ/kgºC para muestras sólidas y 1,38 kJ/kgºC para las fluidas. Los resultados son de utilidad para el diseño del proceso industrial, para la determinación del requerimiento térmico para el calentamiento de ulexita calcinada y para la obtención de una frita.

  8. Densities and derived thermodynamic properties of 1-heptanol and 2-heptanol at temperatures from 313 K to 363 K and pressures up to 22 MPa

    Energy Technology Data Exchange (ETDEWEB)

    Zuniga-Moreno, Abel [Laboratorio de Termodinamica, ESIQIE, Instituto Politecnico Nacional, Edif. Z, Secc. 6, 1er piso, UPALM Zacatenco, 07738 Lindavista, Mexico, D.F. (Mexico); Galicia-Luna, Luis A. [Laboratorio de Termodinamica, ESIQIE, Instituto Politecnico Nacional, Edif. Z, Secc. 6, 1er piso, UPALM Zacatenco, 07738 Lindavista, Mexico, D.F. (Mexico)], E-mail: lgalicial@ipn.mx; Betancourt-Cardenas, Felix F. [Laboratorio de Termodinamica, ESIQIE, Instituto Politecnico Nacional, Edif. Z, Secc. 6, 1er piso, UPALM Zacatenco, 07738 Lindavista, Mexico, D.F. (Mexico)

    2008-01-15

    Experimental densities were determined in liquid phase for 1-heptanol and 2-heptanol at temperatures from 313 K to 363 K and pressures up to 22 MPa using a vibrating tube densimeter. Water and nitrogen were used as reference fluids for the calibration of the vibrating tube densimeter. The uncertainties of the experimental measurements in the whole range of reported data are estimated to be {+-}0.03 K for temperature, {+-}0.008 MPa for pressure, and {+-}0.20 kg . m{sup -3} for density. The experimental data are correlated using a short empirical equation of six parameters and the 11-parameter Benedict-Webb-Rubin-Starling equation of state (BWRS EoS) using a least square optimization. Statistical values to evaluate the different correlations are reported. Published density data of 1-heptanol are compared with values calculated with the 6-parameter equation using the parameters obtained in this work. The experimental data determined here are also compared with an available correlation for 1-heptanol. Densities of 2-heptanol at high pressure were not found in the literature and the data reported here represent the first set of data reported in the literature. Isothermal compressibilities and isobaric thermal expansivity are calculated using the 6-parameter equation for both alcohols within uncertainties estimated to be {+-}0.025 Gpa{sup -1} and {+-}4 x 10{sup -7} K{sup -1}, respectively.

  9. Densities and derived thermodynamic properties of 1-heptanol and 2-heptanol at temperatures from 313 K to 363 K and pressures up to 22 MPa

    International Nuclear Information System (INIS)

    Zuniga-Moreno, Abel; Galicia-Luna, Luis A.; Betancourt-Cardenas, Felix F.

    2008-01-01

    Experimental densities were determined in liquid phase for 1-heptanol and 2-heptanol at temperatures from 313 K to 363 K and pressures up to 22 MPa using a vibrating tube densimeter. Water and nitrogen were used as reference fluids for the calibration of the vibrating tube densimeter. The uncertainties of the experimental measurements in the whole range of reported data are estimated to be ±0.03 K for temperature, ±0.008 MPa for pressure, and ±0.20 kg . m -3 for density. The experimental data are correlated using a short empirical equation of six parameters and the 11-parameter Benedict-Webb-Rubin-Starling equation of state (BWRS EoS) using a least square optimization. Statistical values to evaluate the different correlations are reported. Published density data of 1-heptanol are compared with values calculated with the 6-parameter equation using the parameters obtained in this work. The experimental data determined here are also compared with an available correlation for 1-heptanol. Densities of 2-heptanol at high pressure were not found in the literature and the data reported here represent the first set of data reported in the literature. Isothermal compressibilities and isobaric thermal expansivity are calculated using the 6-parameter equation for both alcohols within uncertainties estimated to be ±0.025 Gpa -1 and ±4 x 10 -7 K -1 , respectively

  10. High temperature thermoelectric properties of strontium titanate thin films with oxygen vacancy and niobium doping

    KAUST Repository

    Sarath Kumar, S. R.; Barasheed, Abeer Z.; Alshareef, Husam N.

    2013-01-01

    We report the evolution of high temperature thermoelectric properties of SrTiO3 thin films doped with Nb and oxygen vacancies. Structure-property relations in this important thermoelectric oxide are elucidated and the variation of transport properties with dopant concentrations is discussed. Oxygen vacancies are incorporated during growth or annealing in Ar/H2 above 800 K. An increase in lattice constant due to the inclusion of Nb and oxygen vacancies is found to result in an increase in carrier density and electrical conductivity with simultaneous decrease in carrier effective mass and Seebeck coefficient. The lattice thermal conductivity at 300 K is found to be 2.22 W m-1 K-1, and the estimated figure of merit is 0.29 at 1000 K. © 2013 American Chemical Society.

  11. High temperature thermoelectric properties of strontium titanate thin films with oxygen vacancy and niobium doping

    KAUST Repository

    Sarath Kumar, S. R.

    2013-08-14

    We report the evolution of high temperature thermoelectric properties of SrTiO3 thin films doped with Nb and oxygen vacancies. Structure-property relations in this important thermoelectric oxide are elucidated and the variation of transport properties with dopant concentrations is discussed. Oxygen vacancies are incorporated during growth or annealing in Ar/H2 above 800 K. An increase in lattice constant due to the inclusion of Nb and oxygen vacancies is found to result in an increase in carrier density and electrical conductivity with simultaneous decrease in carrier effective mass and Seebeck coefficient. The lattice thermal conductivity at 300 K is found to be 2.22 W m-1 K-1, and the estimated figure of merit is 0.29 at 1000 K. © 2013 American Chemical Society.

  12. Progress in Primary Acoustic Thermometry at NIST: 273 K to 505 K

    Science.gov (United States)

    Strouse, G. F.; Defibaugh, D. R.; Moldover, M. R.; Ripple, D. C.

    2003-09-01

    The NIST Acoustic Thermometer determines the thermodynamic temperature by measuring the speed of sound of argon in a spherical cavity. We obtained the thermodynamic temperature of three fixed points on the International Temperature Scale of 1990: the melting point of gallium [T(Ga) = 302.9146 K] and the freezing points of indium [T(In) = 429.7485 K] and tin [T(Sn) = 505.078 K]. The deviations of thermodynamic temperature from the ITS-90 defined temperatures are T - T90 = (4.7 ± 0.6) mK at T(Ga) , T - T90 = (8.8 ± 1.5) mK at T(In) , and T - T90 = (10.7 ± 3.0) mK at T(Sn) , where the uncertainties are for a coverage factor of k = 1. Our results at T(In) and T(Sn) reduce the uncertainty of T - T90 by a factor of two in this range. Both T - T90 at T(Ga) and the measured thermal expansion of the resonator between the triple point of water and T(Ga) are in excellent agreement with the 1992 determination at NIST. The dominant uncertainties in the present data come from frequency-dependent and time-dependent crosstalk between the electroacoustic transducers. We plan to reduce these uncertainties and extend this work to 800 K.

  13. Super cool X-1000 and Super cool Z-1000, two ice blockers, and their effect on vitrification/warming of mouse embryos.

    Science.gov (United States)

    Badrzadeh, H; Najmabadi, S; Paymani, R; Macaso, T; Azadbadi, Z; Ahmady, A

    2010-07-01

    To evaluate the survival and blastocyst formation rates of mouse embryos after vitrification/thaw process with different ice blocker media. We used X-1000 and Z-1000 separately and mixed using V-Kim, a closed vitrification system. Mouse embryos were vitrified using ethylene glycol based medium supplemented with Super cool X-1000 and/or Super cool Z-1000. Survival rates for the control, Super cool X-1000, Super cool Z-1000, and Super cool X-1000/Z-1000 groups were 74%, 72%, 68%, and 85% respectively, with no significant difference among experimental and control groups; however, a significantly higher survival rate was noticed in the Super cool X-1000/Z-1000 group when compared with the Super cool Z-1000 group. Blastocyst formation rates for the control, Super cool X-1000, Super cool Z-1000, and Super cool X-1000/Z-1000 groups were 71%, 66%, 65%, and 72% respectively. There was no significant difference in this rate among control and experimental groups. In a closed vitrification system, addition of ice blocker Super cool X-1000 to the vitrification solution containing Super cool Z-1000 may improve the embryo survival rate. We recommend combined ice blocker usage to optimize the vitrification outcome. Copyright (c) 2010 Elsevier Ireland Ltd. All rights reserved.

  14. Trans-suppression of host CDH3 and LOXL4 genes during Cryptosporidium parvum infection involves nuclear delivery of parasite Cdg7_FLc_1000 RNA.

    Science.gov (United States)

    Ming, Zhenping; Gong, Ai-Yu; Wang, Yang; Zhang, Xin-Tian; Li, Min; Li, Yao; Pang, Jing; Dong, Stephanie; Strauss-Soukup, Juliane K; Chen, Xian-Ming

    2018-05-01

    Intestinal infection by Cryptosporidium parvum causes significant alterations in the gene expression profile in host epithelial cells. Previous studies demonstrate that a panel of parasite RNA transcripts of low protein-coding potential are delivered into infected host cells and may modulate host gene transcription. Using in vitro models of human intestinal cryptosporidiosis, we report here that trans-suppression of the cadherin 3 (CDH3) and lysyl oxidase like 4 (LOXL4) genes in human intestinal epithelial cells following C. parvum infection involves host delivery of the Cdg7_FLc_1000 RNA, a C. parvum RNA that has been previously demonstrated to be delivered into the nuclei of infected host cells. Downregulation of CDH3 and LOXL4 genes was detected in host epithelial cells following C. parvum infection or in cells expressing the parasite Cdg7_FLc_1000 RNA. Knockdown of Cdg7_FLc_1000 attenuated the trans-suppression of CDH3 and LOXL4 genes in host cells induced by infection. Interestingly, Cdg7_FLc_1000 was detected to be recruited to the promoter regions of both CDH3 and LOXL4 gene loci in host cells following C. parvum infection. Host delivery of Cdg7_FLc_1000 promoted the PH domain zinc finger protein 1 (PRDM1)-mediated H3K9 methylation associated with trans-suppression in the CDH3 gene locus, but not the LOXL4 gene. Therefore, our data suggest that host delivery of Cdg7_FLc_1000 causes CDH3 trans-suppression in human intestinal epithelial cells following C. parvum infection through PRDM1-mediated H3K9 methylation in the CDH3 gene locus, whereas Cdg7_FLc_1000 induces trans-suppression of the host LOXL4 gene through H3K9/H3K27 methylation-independent mechanisms. Copyright © 2018 Australian Society for Parasitology. Published by Elsevier Ltd. All rights reserved.

  15. Measurement of the (pressure, density, temperature) relation of two (methane + nitrogen) gas mixtures at temperatures between 240 and 400 K and pressures up to 20 MPa using an accurate single-sinker densimeter

    International Nuclear Information System (INIS)

    Chamorro, C.R.; Segovia, J.J.; Martin, M.C.; Villamanan, M.A.; Estela-Uribe, J.F.; Trusler, J.P.M.

    2006-01-01

    Comprehensive (p, ρ, T) measurements on two gas mixtures of (0.9CH 4 + 0.1N 2 ) and (0.8CH 4 + 0.2N 2 ) have been carried out at six temperatures between 240 and 400 K and at pressures up to 20 MPa. A total of 108 (p, ρ, T) data for the first mixture and 134 for the second one are given. These measurements were performed using a compact single-sinker densimeter based on Archimedes' buoyancy principle. The overall uncertainty in density ρ is estimated to be (1.5 . 10 -4 . ρ + 2 . 10 -3 kg . m -3 ) (coverage factor k = 2), the uncertainty in temperature T is estimated to be 0.006 K (coverage factor k = 2), and the uncertainty in pressure p is estimated to be 1 . 10 -4 .p (coverage factor k = 2). The equipment has been previously checked with pure nitrogen over the whole temperature and pressure working ranges and experimental results (35 values) are given and a comparison with the reference equation of state for nitrogen is presented

  16. Recent studies of the ion emission from high-current PF-1000 experiments

    International Nuclear Information System (INIS)

    Skladnik-Sadowska, E.; Sadowski, M.J.; Czaus, K.; Malinowski, K.; Kwiatkowski, R.; Zebrowski, J.; Sadowski, M.J.; Karpinski, L.; Paduch, M.; Scholz, M.; Garkusha, I.E.

    2010-01-01

    The paper describes diagnostics of fast ion beams emitted from a large PF-1000 facility operated at 21...27 kV, 290...480 kJ. Those beams were measured with pinhole cameras and PM-355 nuclear track detectors, placed at different angles to the discharge axis. The measurements showed a complex spatial structure of the fast ion beams. Measurements behind an axial channel in the inner electrode have shown that some ion beams are emitted also in the upstream direction. The ion energy spectra were measured with a miniature Thomson-type spectrometer. Time-resolved measurements of ions were performed with miniature scintillation detectors placed behind a pinhole.

  17. Experience running in and improvement of secondary circuit water chemistry of Kalinin NPP WWER-1000

    International Nuclear Information System (INIS)

    Noev, V.V.; Kukharev, N.D.; Otchenashev, G.D.; Guzeeva, G.I.; Kochetova, G.G.

    1991-01-01

    Basic characteristics of the secondary circuit water-chemical conditions at the Kalinin 1 and 2 reactors are presented. These are the WWER-1000 reactors with K-1000-1500 turbines. The analysis conducted makes it possible to conclude that all indicated values can meet the standards by introducing the hydrazine-ammonium regime in the secondary circuit with feedwater pH value equal to 9±0.2. Realization of design scheme for condensate-feeding circuit washing is necessary for acceleration of the water-chemical mode stabilization. Moreover the units should be equipped with automated chemical control instrumentation of a new generation

  18. Volumetric properties of binary mixtures of ionic liquid 1-butyl-3-methylimidazolium octylsulfate with water or propanol in the temperature range of 278.15K to 328.15K

    International Nuclear Information System (INIS)

    Orchilles, A. Vicent; Gonzalez-Alfaro, Vicenta; Miguel, Pablo J.; Vercher, Ernesto; Martinez-Andreu, Antoni

    2006-01-01

    Densities of 1-butyl-3-methylimidazolium octylsulfate ([bmim][OcOSO 3 ]) solutions in water and 1-propanol have been measured with an oscillating-tube densimeter at temperatures from 278.15K to 328.15K. From these densities, apparent molar volumes V φ of [bmim][OcOSO 3 ] in both solvents have been calculated, and its dependence on the molality has been treated with the Redlich and Meyer equation. Debye-Huckel limiting slopes for 1-propanol at working temperatures have been calculated, and apparent molar volumes of [bmim][OcOSO 3 ] at infinite dilution V φ o in both solvents have been evaluated. The partial molar volume at infinite dilution of [bmim][OcOSO 3 ] in water is higher than in 1-propanol and augments when the temperature augments. On the other hand, the partial molar volume at infinite dilution of [bmim][OcOSO 3 ] in 1-propanol decreases when the temperature augments

  19. 14C SIRI samples at CNA: Measurements at 200 kV and 1000 kV

    International Nuclear Information System (INIS)

    Santos Arévalo, Francisco-Javier; Gómez Martínez, Isabel; Agulló García, Lidia

    2015-01-01

    The Sixth International Radiocarbon Intercomparison (SIRI) exercise has taken place during late 2013 and 2014. 13 samples were distributed for AMS (Accelerator Mass Spectrometry) and 5 for radiometric laboratories, including one sample exclusively for radiometric laboratories. Being the first opportunity for our laboratory to participate actively in an intercomparison exercise, we have prepared and measured the samples in the two existing AMS dedicated facilities at the Centro Nacional de Aceleradores (CNA): SARA (Spanish Accelerator for Radionuclide Analysis), a 1 MV multielemental AMS system from HVEE, and Micadas, a 200 kV radiocarbon dating system designed by ETH. Results are presented for the two systems, together with a description of both the sample preparation and measurement procedures.

  20. 14C SIRI samples at CNA: Measurements at 200 kV and 1000 kV

    Science.gov (United States)

    Santos Arévalo, Francisco-Javier; Gómez Martínez, Isabel; Agulló García, Lidia

    2015-10-01

    The Sixth International Radiocarbon Intercomparison (SIRI) exercise has taken place during late 2013 and 2014. 13 samples were distributed for AMS (Accelerator Mass Spectrometry) and 5 for radiometric laboratories, including one sample exclusively for radiometric laboratories. Being the first opportunity for our laboratory to participate actively in an intercomparison exercise, we have prepared and measured the samples in the two existing AMS dedicated facilities at the Centro Nacional de Aceleradores (CNA): SARA (Spanish Accelerator for Radionuclide Analysis), a 1 MV multielemental AMS system from HVEE, and Micadas, a 200 kV radiocarbon dating system designed by ETH. Results are presented for the two systems, together with a description of both the sample preparation and measurement procedures.

  1. HIGH-TEMPERATURE IONIZATION IN PROTOPLANETARY DISKS

    Energy Technology Data Exchange (ETDEWEB)

    Desch, Steven J. [School of Earth and Space Exploration, Arizona State University, P.O. Box 871404, Tempe, AZ 85287-1404 (United States); Turner, Neal J. [Jet Propulsion Laboratory, Mail Stop 169-506, California Institute of Technology, 4800 Oak Grove Drive, Pasadena, CA 91109 (United States)

    2015-10-01

    We calculate the abundances of electrons and ions in the hot (≳500 K), dusty parts of protoplanetary disks, treating for the first time the effects of thermionic and ion emission from the dust grains. High-temperature ionization modeling has involved simply assuming that alkali elements such as potassium occur as gas-phase atoms and are collisionally ionized following the Saha equation. We show that the Saha equation often does not hold, because free charges are produced by thermionic and ion emission and destroyed when they stick to grain surfaces. This means the ionization state depends not on the first ionization potential of the alkali atoms, but rather on the grains’ work functions. The charged species’ abundances typically rise abruptly above about 800 K, with little qualitative dependence on the work function, gas density, or dust-to-gas mass ratio. Applying our results, we find that protoplanetary disks’ dead zone, where high diffusivities stifle magnetorotational turbulence, has its inner edge located where the temperature exceeds a threshold value ≈1000 K. The threshold is set by ambipolar diffusion except at the highest densities, where it is set by Ohmic resistivity. We find that the disk gas can be diffusively loaded onto the stellar magnetosphere at temperatures below a similar threshold. We investigate whether the “short-circuit” instability of current sheets can operate in disks and find that it cannot, or works only in a narrow range of conditions; it appears not to be the chondrule formation mechanism. We also suggest that thermionic emission is important for determining the rate of Ohmic heating in hot Jupiters.

  2. HIGH-TEMPERATURE IONIZATION IN PROTOPLANETARY DISKS

    International Nuclear Information System (INIS)

    Desch, Steven J.; Turner, Neal J.

    2015-01-01

    We calculate the abundances of electrons and ions in the hot (≳500 K), dusty parts of protoplanetary disks, treating for the first time the effects of thermionic and ion emission from the dust grains. High-temperature ionization modeling has involved simply assuming that alkali elements such as potassium occur as gas-phase atoms and are collisionally ionized following the Saha equation. We show that the Saha equation often does not hold, because free charges are produced by thermionic and ion emission and destroyed when they stick to grain surfaces. This means the ionization state depends not on the first ionization potential of the alkali atoms, but rather on the grains’ work functions. The charged species’ abundances typically rise abruptly above about 800 K, with little qualitative dependence on the work function, gas density, or dust-to-gas mass ratio. Applying our results, we find that protoplanetary disks’ dead zone, where high diffusivities stifle magnetorotational turbulence, has its inner edge located where the temperature exceeds a threshold value ≈1000 K. The threshold is set by ambipolar diffusion except at the highest densities, where it is set by Ohmic resistivity. We find that the disk gas can be diffusively loaded onto the stellar magnetosphere at temperatures below a similar threshold. We investigate whether the “short-circuit” instability of current sheets can operate in disks and find that it cannot, or works only in a narrow range of conditions; it appears not to be the chondrule formation mechanism. We also suggest that thermionic emission is important for determining the rate of Ohmic heating in hot Jupiters

  3. Temperature and pressure distributions in a 400 kW{sub t} fluidized bed straw gasifier

    Energy Technology Data Exchange (ETDEWEB)

    Erguedenler, A.; Ghaly, A.E.; Hamdullahpur, F. [Technical Univ. of Nova Scotia, Halifax (Canada)

    1993-12-31

    The temperature and pressure distribution characteristics of a 400 kW (thermal) dual-distributor type fluidized bed straw gasifier were investigated. The effects of the bed height, equivalence ratio (actual air-fuel ratio:stoichiometric air-fuel ratio) and fluidization velocity on the temperature and pressure variations in the gasifier were studied. Generally, the bed temperature reached the steady state condition within 15--20 minutes. The average temperature of the dense bed ranged from 649{degrees}C to 875{degrees}C depending on the levels of operating parameters used. The bed temperature increased linearly with increases in the equivalence ratio, higher bed temperatures were observed with lower bed height and no clear trend for the bed temperature with respect to variations in fluidization velocity was observed. The bed height, equivalence ratio and fluidization velocity affected the pressure drop in the fluidized bed gasifier. Increasing the fluidization velocity and/or decreasing the equivalence ratio resulted in higher pressure drops in the dense bed and the freeboard regions whereas increasing the bed height increased the pressure drop only in the dense bed.

  4. 42 CFR 1000.10 - General definitions.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false General definitions. 1000.10 Section 1000.10 Public Health OFFICE OF INSPECTOR GENERAL-HEALTH CARE, DEPARTMENT OF HEALTH AND HUMAN SERVICES GENERAL PROVISIONS INTRODUCTION; GENERAL DEFINITIONS Definitions § 1000.10 General definitions. In this chapter...

  5. High temperature oxidation kinetics of dysprosium particles

    Energy Technology Data Exchange (ETDEWEB)

    Jaques, Brian J.; Butt, Darryl P., E-mail: DarrylButt@BoiseState.edu

    2015-09-25

    Highlights: • The oxidation behavior of dysprosium particles was studied from 500 to 1000 °C. • Activation energy in initial region found as 8–25 kJ/mol, depending on atmosphere. • Activation energy in intermediate region found as 80–95 kJ/mol. • The oxide grows at the metal–oxide interface. • Generally, the formed oxide behaved as a p-type semiconductor. - Abstract: Rare earth elements have been recognized as critical materials for the advancement of many strategic and green technologies. Recently, the United States Department of Energy has invested many millions of dollars to enhance, protect, and forecast their production and management. The work presented here attempts to clarify the limited and contradictory literature on the oxidation behavior of the rare earth metal, dysprosium. Dysprosium particles were isothermally oxidized from 500 to 1000 °C in N{sub 2}–(2%, 20%, and 50%) O{sub 2} and Ar–20% O{sub 2} using simultaneous thermal analysis techniques. Two distinct oxidation regions were identified at each isothermal temperature in each oxidizing atmosphere. Initially, the oxidation kinetics are very fast until the reaction enters a slower, intermediate region of oxidation. The two regions are defined and the kinetics of each are assessed to show an apparent activation energy of 8–25 kJ/mol in the initial region and 80–95 kJ/mol in the intermediate oxidation reaction region. The effects of varying the oxygen partial pressure on the reaction rate constant are used to show that dysprosium oxide (Dy{sub 2}O{sub 3}) generally acts as a p-type semiconductor in both regions of oxidation (with an exception above 750 °C in the intermediate region)

  6. 7 CFR 1000.6 - Supply plant.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 9 2010-01-01 2009-01-01 true Supply plant. 1000.6 Section 1000.6 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing Agreements... Definitions § 1000.6 Supply plant. Supply plant means a plant approved by a duly constituted regulatory agency...

  7. 12 CFR 611.1000 - General authority.

    Science.gov (United States)

    2010-01-01

    ... 12 Banks and Banking 6 2010-01-01 2010-01-01 false General authority. 611.1000 Section 611.1000 Banks and Banking FARM CREDIT ADMINISTRATION FARM CREDIT SYSTEM ORGANIZATION Bank Mergers, Consolidations and Charter Amendments § 611.1000 General authority. (a) An amendment to a bank charter may relate...

  8. Densities and volumetric properties of (acetonitrile+an amide) binary mixtures at temperatures between 293.15K and 318.15K

    International Nuclear Information System (INIS)

    Nain, Anil Kumar

    2006-01-01

    The densities of binary mixtures of acetonitrile (ACN) with formamide (FA), N,N-dimethylformamide (DMF), N-methylacetamide (NMA), and N,N-dimethylacetamide (DMA), including those of pure liquids, over the entire composition range were measured at temperatures (293.15, 298.15, 303.15, 308.15, 313.15, and 318.15) K and atmospheric pressure. From the experimental data, the excess molar volume, V m E , and partial molar volumes, V-bar m,1 and V-bar m,2 , were calculated over whole composition range. The variation of these parameters with composition and temperature of the mixtures has been discussed in terms of molecular interaction in these mixtures. The V m E values were found negative for all the mixtures and at each temperature studied, indicating the presence of specific interactions between ACN and amide molecules. The extent of negative deviations in V m E values follows the order: FA>NMA>DMA>DMF. It is observed that the V m E values depend upon the positions of methyl groups in these amide molecules

  9. Neutronic and thermal-hydraulic calculations for the AP-1000 NPP with the MCNP6 and SERPENT codes

    International Nuclear Information System (INIS)

    Stefani, Giovanni Laranjo; Maiorino, Jose R.; Santos, Thiago A.

    2015-01-01

    The AP-1000 is an evolutionary PWR reactor designed as an evolution of the AP-600 project. The reactor is already pre-licensed by NRC, and is considered to have achieved high standards of safety, possible short construction time and good economic competitiveness. The core is a 17x17 typical assembly using Zirlo as cladding, 3 different enrichment regions, and is controlled by boron, control banks, and burnable poison. The expected fuel final burnup is 62 MWD/ton U and a cycle of 18 months. In this paper we present results for neutronic and thermal-hydraulic calculations for the AP-1000. We use the MCNP6 and SERPENT codes to calculate the first cycle of operation. The calculated parameters are K eff at BOL and EOL and its variation with burnup and neutron flux, and reactivity coefficients. The production of transuranic elements such as Pu-239 and Pu-241, and burning fuel are calculated over time. In the work a complete reactor was burned for 450 days with no control elements, boron or burnable poison were considered, these results were compared with data provided by the Westinghouse. The results are compared with those reported in the literature. A simple thermal hydraulic analysis allows verification of thermal limits such as fuel and cladding temperatures, and MDNB. (author)

  10. Neutronic and thermal-hydraulic calculations for the AP-1000 NPP with the MCNP6 and SERPENT codes

    Energy Technology Data Exchange (ETDEWEB)

    Stefani, Giovanni Laranjo; Maiorino, Jose R.; Santos, Thiago A., E-mail: giovanni.laranjo@ufabc.edu.br, E-mail: joserubens.maiorino@ufabc.edu.br, E-mail: thiago.santos@ufabc.edu.br [Universidade Federal do ABC (CECS/UFABC), Santo Andre, SP (Brazil). Centro de Engenharia, Modelagem e Ciencias Sociais; Rossi, Pedro R., E-mail: pedro.russorossi@gmail.com [FERMIUM - Tecnologia Nuclear, Sao Paulo, SP (Brazil)

    2015-07-01

    The AP-1000 is an evolutionary PWR reactor designed as an evolution of the AP-600 project. The reactor is already pre-licensed by NRC, and is considered to have achieved high standards of safety, possible short construction time and good economic competitiveness. The core is a 17x17 typical assembly using Zirlo as cladding, 3 different enrichment regions, and is controlled by boron, control banks, and burnable poison. The expected fuel final burnup is 62 MWD/ton U and a cycle of 18 months. In this paper we present results for neutronic and thermal-hydraulic calculations for the AP-1000. We use the MCNP6 and SERPENT codes to calculate the first cycle of operation. The calculated parameters are K{sub eff} at BOL and EOL and its variation with burnup and neutron flux, and reactivity coefficients. The production of transuranic elements such as Pu-239 and Pu-241, and burning fuel are calculated over time. In the work a complete reactor was burned for 450 days with no control elements, boron or burnable poison were considered, these results were compared with data provided by the Westinghouse. The results are compared with those reported in the literature. A simple thermal hydraulic analysis allows verification of thermal limits such as fuel and cladding temperatures, and MDNB. (author)

  11. Magnetic ordering of quasi-1 D S=1/2 Heisenberg antiferromagnet Cu benzoate at sub-mK temperatures

    International Nuclear Information System (INIS)

    Karaki, Y.; Masutomi, R.; Kubota, M.; Ishimoto, H.; Asano, T.; Ajiro, Y.

    2003-01-01

    We have measured the AC susceptibility of quasi-1D S=1/2 Heisenberg antiferromagnet Cu benzoate at temperatures down to 0.2 mK. A sharp susceptibility peak is observed at 0.8 mK under an earth field. This fact indicates a 3D ordering of linear chains coupled by a weak magnetic interaction between chains

  12. Reaction F + C2H4: Rate Constant and Yields of the Reaction Products as a Function of Temperature over 298-950 K.

    Science.gov (United States)

    Bedjanian, Yuri

    2018-03-29

    The kinetics and products of the reaction of F + C 2 H 4 have been studied in a discharge flow reactor combined with an electron impact ionization mass spectrometer at nearly 2 Torr total pressure of helium in the temperature range 298-950 K. The total rate constant of the reaction, k 1 = (1.78 ± 0.30) × 10 -10 cm 3 molecule -1 s -1 , determined under pseudo-first-order conditions, monitoring the kinetics of F atom consumption in excess of C 2 H 4 , was found to be temperature independent in the temperature range used. H, C 2 H 3 F, and HF were identified as the reaction products. Absolute measurements of the yields of these species allowed to determine the branching ratios, k 1b / k 1 = (0.73 ± 0.07) exp(-(425 ± 45)/ T) and k 1a / k 1 = 1 - (0.73 ± 0.07) exp(-(425 ± 45)/ T) and partial rate constants for addition-elimination (H + C 2 H 3 F) and H atom abstraction (HF + C 2 H 3 ) pathways of the title reaction: k 1a = (0.80 ± 0.07) × 10 -10 exp(189 ± 37/ T) and k 1b = (1.26 ± 0.13) × 10 -10 exp(-414 ± 45/ T) cm 3 molecule -1 s -1 , respectively, at T = 298-950 K and with 2σ quoted uncertainties. The overall reaction rate constant can be adequately described by both the temperature independent value and as a sum of k 1a and k 1b . The kinetic and mechanistic data from the present study are discussed in comparison with previous absolute and relative measurements and theoretical calculations.

  13. High voltage nanosecond generator with pulse repetition rate of 1,000 p.p.s.

    Energy Technology Data Exchange (ETDEWEB)

    Gubanov, V P; Korovin, S D; Stepchenko, A S [High Current Electronics Institute, Tomsk (Russian Federation)

    1997-12-31

    A compact high voltage nanosecond generator is described with a pulse repetition rate up to 1000 p.p.s. The generator includes a 30-Ohm coaxial forming line charged by a built-in Tesla transformer with a high coupling coefficient, and a high voltage (N{sub 2}) gas gap switch with gas blowing between the electrodes. The maximum forming line charge voltage is 450 kV, the pulse duration is about 4 ns, and its amplitude for a matched load is up to 200 kV. (author). 3 figs., 9 refs.

  14. AP1000, a nuclear central of advanced design; AP1000, una central nuclear de diseno avanzado

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez M, N.; Viais J, J. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)]. e-mail: nhm@nuclear.inin.mx

    2005-07-01

    The AP1000 is a design of a nuclear reactor of pressurized water (PWR) of 1000 M We with characteristic of safety in a passive way; besides presenting simplifications in the systems of the plant, the construction, the maintenance and the safety, the AP1000 is a design that uses technology endorsed by those but of 30 years of operational experience of the PWR reactors. The program AP1000 of Westinghouse is focused to the implementation of the plant to provide improvements in the economy of the same one and it is a design that is derived directly of the AP600 designs. On September 13, 2004 the US-NRC (for their initials in United States- Nuclear Regulatory Commission) approved the final design of the AP1000, now Westinghouse and the US-NRC are working on the whole in a complete program for the certification. (Author)

  15. Text Mining Untuk Analisis Sentimen Review Film Menggunakan Algoritma K-Means

    Directory of Open Access Journals (Sweden)

    Setyo Budi

    2017-02-01

    Full Text Available Kemudahan manusia didalam menggunakan website mengakibatkan bertambahnya dokumen teks yang berupa pendapat dan informasi. Dalam waktu yang lama dokumen teks akan bertambah besar. Text mining merupakan salah satu teknik yang digunakan untuk menggali kumpulan dokumen text sehingga dapat diambil intisarinya. Ada beberapa algoritma yang di gunakan untuk penggalian dokumen untuk analisis sentimen, salah satunya adalah K-Means. Didalam penelitian ini algoritma yang digunakan adalah K-Means. Hasil penelitian menunjukkan bahwa akurasi K-Means dengan dataset digunakan 300 positif dan 300 negatif  akurasinya 57.83%,  700 dokumen positif dan 700  negatif akurasinya 56.71%%, 1000 dokumen positif dan 1000  negatif akurasinya 50.40%%. Dari hasil pengujian disimpulkan bahwa semakin besar dataset yang digunakan semakin rendah akurasi K-Means.   Kata Kunci : Text Mining, Analisis Sentimen, K-Means, Review Film 

  16. 21 CFR 589.1000 - Gentian violet.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Gentian violet. 589.1000 Section 589.1000 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL DRUGS... Substances Prohibited From Use in Animal Food or Feed § 589.1000 Gentian violet. The Food and Drug...

  17. United States National Grid for New Mexico, UTM 12, (1000m X 1000m polygons )

    Data.gov (United States)

    Earth Data Analysis Center, University of New Mexico — This is a polygon feature data layer of United States National Grid (1000m x 1000m polygons ) constructed by the Center for Interdisciplinary Geospatial Information...

  18. United States National Grid for New Mexico, UTM 13, (1000m X 1000m polygons )

    Data.gov (United States)

    Earth Data Analysis Center, University of New Mexico — This is a polygon feature data layer of United States National Grid (1000m x 1000m polygons ) constructed by the Center for Interdisciplinary Geospatial Information...

  19. First-principles study of optical, elastic anisotropic and thermodynamic properties of TiN under high temperature and high pressure

    Directory of Open Access Journals (Sweden)

    R. Yang

    2017-12-01

    Full Text Available The optical, elastic anisotropic and thermodynamic properties of TiN in the NaCl (B1 structure are analyzed in detail in the temperature range from 0 to 2000 K and the pressure range from 0 to 20 GPa. From the calculated dielectric constants, a first order isostructural phase transition between 29 and 30 GPa is found for TiN. The absorption spectra exhibit high values ranging from the far infrared region to the ultra-violet one. The anisotropy value of Young's modulus of TiN is smaller than that of c-BN at 0 GPa and the anisotropy of TiN clearly increases with an increase of pressure. The effects of pressure and temperature on the bulk modulus, Grüneisen parameter, Gibbs free energy, and Debye temperature are significant. The Grüneisen parameter of TiN is much larger than that of c-BN. At temperatures below 1000 K, TiN's heat capacity is much larger than that of c-BN.

  20. Post-IR IRSL290 dating of K-rich feldspar sand grains in a wind-dominated system on Sardinia

    DEFF Research Database (Denmark)

    Andreucci, S.; Sechi, D.; Buylaert, Jan-Pieter

    2017-01-01

    The reliability of a post-IR elevated temperature IRSL (290 °C; pIRIR290) is tested on wind-blown, sand-sized (180–250 μm) K-rich feldspar grains. The pIRIR290 ages were compared with quartz SAR-OSL data, other independent age controls and historical information. Three study areas along the coast....... The pIRIR290 ages indicate an offset up to ∼1000 years. We can conclude that the pIRIR290 method on sand-sized K-feldspar grains shows great promise for samples at or beyond the quartz OSL age limit but should not be applied to Late Holocene or modern deposits....

  1. 1000 MW steam turbine for Temelin nuclear power station

    International Nuclear Information System (INIS)

    Drahy, J.

    1992-01-01

    Before the end 1991 the delivery was completed of the main parts (3 low-pressure sections and 1 high-pressure section, all of double-flow design) of the first full-speed (3000 r.p.m.) 1000 MW steam turbine for saturated admission steam for the Temelin nuclear power plant. Description of the turbine design and of new technologies and tools used in the manufacture are given. Basic technical parameters of the steam turbine are as follows: maximum output of steam generators 6060 th -1 ; maximum steam flow into turbine 5494.7 th -1 ; output of turbo-set 1024 MW; steam conditions before the turbine inlet: pressure 5.8 MPa, temperature 273.3 degC, steam wetness 0.5%; nominal temperature of cooling water 21 degC; temperature of feed water 220.8 degC; maximum consumption of heat from turbine for heating at 3-stage heating of heating water 60/150 degC. (Z.S.) 7 figs., 2 refs

  2. High temperature measurement by noise thermometry

    International Nuclear Information System (INIS)

    Decreton, M.C.

    1982-06-01

    Noise thermometry has received a lot of attention for measurements of temperatures in the high range around 1000-2000 deg. K. For these measurements, laboratory type experiments have been mostly performed. These have shown the interest of the technique when long term stability, high precision and insensibility to external conditions are concerned. This is particularly true for measurements in nuclear reactors where important drifts due to irradiation effects are experienced with other measurement techniques, as thermocouple for instance. Industrial noise thermometer experiments have not been performed extensively up to now. The subject of the present study is the development of a 1800 deg. K noise thermometer for nuclear applications. The measurement method is based on a generalized noise power approach. The rms noise voltage (Vsub(s)) and noise current (Isub(s)) are successively measured on the resistive sensor. The same quantities are also measured on a dummy short circuited probe (Vsub(d) and Isub(d)). The temperature is then deduced from these measured values by the following formula: cTsub(s) = (Vsub(s) 2 - Vsub(d) 2 )(Vsub(s)/Isub(s) - Vsub(d)/Isub(d)) - 1 , where c is a constant and Tsub(s) the absolute temperature of the sensor. This approach has the particular advantage of greatly reducing the sensibility to environmental perturbations on the leads and to the influence of amplifier noise sources. It also eliminates the necessity of resistance measurement and keeps the electronic circuits as simple as possible

  3. Creep and stress-relaxation in bending, at 673 K, of cold-worked Zircaloy-4

    International Nuclear Information System (INIS)

    Povolo, F.; Marzocca, A.J.

    1981-01-01

    Data of creep and stress-relaxation in bending at 673 K and up to times of the order of 1000 h, in cold-worked Zry-4, are discussed. It is shown that the results, previously interpreted in terms of Hart's phenomenological equation of state for high homologous temperatures, can be described also by an equation of the type E = B(αsigma), which has more precise physical meaning in terms of thermally activated motion of dislocations. Finally, it is shown that the hyperbolic sine representation satisfies the conditions for an equation of state and some dislocation parameters are calculated. (orig.)

  4. The impact of temperature changes on summer time ozone and its precursors in the Eastern Mediterranean

    Directory of Open Access Journals (Sweden)

    U. Im

    2011-04-01

    Full Text Available Changes in temperature due to variability in meteorology and climate change are expected to significantly impact atmospheric composition. The Mediterranean is a climate sensitive region and includes megacities like Istanbul and large urban agglomerations such as Athens. The effect of temperature changes on gaseous air pollutant levels and the atmospheric processes that are controlling them in the Eastern Mediterranean are here investigated. The WRF/CMAQ mesoscale modeling system is used, coupled with the MEGAN model for the processing of biogenic volatile organic compound emissions. A set of temperature perturbations (spanning from 1 to 5 K is applied on a base case simulation corresponding to July 2004. The results indicate that the Eastern Mediterranean basin acts as a reservoir of pollutants and their precursor emissions from large urban agglomerations. During summer, chemistry is a major sink at these urban areas near the surface, and a minor contributor at downwind areas. On average, the atmospheric processes are more effective within the first 1000 m above ground. Temperature increases lead to increases in biogenic emissions by 9±3% K−1. Ozone mixing ratios increase almost linearly with the increases in ambient temperatures by 1±0.1 ppb O3 K−1 for all studied urban and receptor stations except for Istanbul, where a 0.4±0.1 ppb O3 K−1 increase is calculated, which is about half of the domain-averaged increase of 0.9±0.1 ppb O3 K−1. The computed changes in atmospheric processes are also linearly related with temperature changes.

  5. Dislocation-mediated trapping of deuterium in tungsten under high-flux high-temperature exposures

    Energy Technology Data Exchange (ETDEWEB)

    Bakaeva, A. [SCK-CEN, Nuclear Materials Science Institute, Boeretang 200, 2400, Mol (Belgium); Department of Applied Physics, Ghent University, St. Pietersnieuwstraat 41, 9000, Ghent (Belgium); Terentyev, D., E-mail: dterenty@sckcen.be [SCK-CEN, Nuclear Materials Science Institute, Boeretang 200, 2400, Mol (Belgium); De Temmerman, G. [ITER Organization, Route de Vinon-sur-Verdon, CS 90 046, 13067, St Paul Lez Durance Cedex (France); Lambrinou, K. [SCK-CEN, Nuclear Materials Science Institute, Boeretang 200, 2400, Mol (Belgium); Morgan, T.W. [FOM Institute DIFFER, De Zaale 20, 5612 AJ, Eindhoven (Netherlands); Dubinko, A.; Grigorev, P. [SCK-CEN, Nuclear Materials Science Institute, Boeretang 200, 2400, Mol (Belgium); Department of Applied Physics, Ghent University, St. Pietersnieuwstraat 41, 9000, Ghent (Belgium); Verbeken, K. [Department of Materials Science and Engineerin, Ghent University, St. Pietersnieuwstraat 41, 9000, Ghent (Belgium); Noterdaeme, J.M. [Department of Applied Physics, Ghent University, St. Pietersnieuwstraat 41, 9000, Ghent (Belgium)

    2016-10-15

    The effect of severe plastic deformation on the deuterium retention in tungsten exposed to high-flux low-energy plasma (flux ∼10{sup 24} m{sup −2} s{sup −1}, energy ∼50 eV and fluence up to 5 × 10{sup 25} D/m{sup 2}) was studied experimentally in a wide temperature range (460–1000 K) relevant for application in ITER. The desorption spectra in both reference and plastically-deformed samples were deconvoluted into three contributions associated with the detrapping from dislocations, deuterium-vacancy clusters and pores. As the exposure temperature increases, the positions of the release peaks in the plastically-deformed material remain in the same temperature range but the peak amplitudes are altered as compared to the reference material. The desorption peak attributed to the release from pores (i.e. cavities and bubbles) was suppressed in the plastically deformed samples for the low-temperature exposures, but became dominant for exposures above 700 K. The observed strong modulation of the deuterium storage in “shallow” and “deep” traps, as well as the reduction of the integral retention above 700 K, suggest that the dislocation network changes its role from “trapping sites” to “diffusion channels” above a certain temperature. The major experimental observations of the present work are in line with recent computational assessment based on atomistic and mean field theory calculations available in literature.

  6. Elements of non-equilibrium (ℎ, k)-dynamics at zero and finite temperatures

    International Nuclear Information System (INIS)

    Golubeva, O.N.; Sukhanov, A.D.

    2011-01-01

    We suggest a method which allows developing some elements of non-equilibrium (ℎ, k)-dynamics without use of Schroedinger equation. It is based on the generalization pf Fokker-Planck and Hamilton-Jacobi equations. Sequential considering of stochastic influence of vacuum is realized in the quantum heat bath model. We show that at the presence of quantum-thermal diffusion non-equilibrium wave functions describe the process of nearing to generalized state of thermal equilibrium at zero and finite temperatures. They can be used as a ground for universal description of transport phenomena

  7. Microprocessor system for temperature regulation and stabilization

    International Nuclear Information System (INIS)

    Nguyen Nhi Dien; Rodionov, K.G.

    1989-01-01

    Microprocessor based system for temperature regulation and stabilization of an operation external object is described. The system has the direct current amplifier working according to modulator-demodulator principle. The overal gain is 100, 1000, 2000. The maximum output signal is ±10 V. The power amplifier is a thyristor one and its line voltage is 220 V, 50 Hz. The output power is 0-2 kVA. The microcontroller has a remote display terminal. Data input is 8 and data output is one. Input and output voltage is ±(0-10) V. The preselection time for stabilization is within 1 s - 18 h. The program algorithm is given. 5 figs.; 1 tab

  8. Measurement of the (pressure, density, temperature) relation of two (methane + nitrogen) gas mixtures at temperatures between 240 and 400 K and pressures up to 20 MPa using an accurate single-sinker densimeter

    Energy Technology Data Exchange (ETDEWEB)

    Chamorro, C.R. [Grupo de Termodinamica y Calibracion (TERMOCAL), Dpto. Ingenieria Energetica y Fluidomecanica, E.T.S. de Ingenieros Industriales, Universidad de Valladolid, E-47071 Valladolid (Spain)]. E-mail: cescha@eis.uva.es; Segovia, J.J. [Grupo de Termodinamica y Calibracion (TERMOCAL), Dpto. Ingenieria Energetica y Fluidomecanica, E.T.S. de Ingenieros Industriales, Universidad de Valladolid, E-47071 Valladolid (Spain); Martin, M.C. [Grupo de Termodinamica y Calibracion (TERMOCAL), Dpto. Ingenieria Energetica y Fluidomecanica, E.T.S. de Ingenieros Industriales, Universidad de Valladolid, E-47071 Valladolid (Spain); Villamanan, M.A. [Grupo de Termodinamica y Calibracion (TERMOCAL), Dpto. Ingenieria Energetica y Fluidomecanica, E.T.S. de Ingenieros Industriales, Universidad de Valladolid, E-47071 Valladolid (Spain); Estela-Uribe, J.F. [Facultad de Ingenieria, Universidad Javeriana-Cali, Calle 18, 118-250 Cali (Colombia); Trusler, J.P.M. [Department of Chemical Engineering, Imperial College London, London SW7 2AZ (United Kingdom)

    2006-07-15

    Comprehensive (p, {rho}, T) measurements on two gas mixtures of (0.9CH{sub 4} + 0.1N{sub 2}) and (0.8CH{sub 4} + 0.2N{sub 2}) have been carried out at six temperatures between 240 and 400 K and at pressures up to 20 MPa. A total of 108 (p, {rho}, T) data for the first mixture and 134 for the second one are given. These measurements were performed using a compact single-sinker densimeter based on Archimedes' buoyancy principle. The overall uncertainty in density {rho} is estimated to be (1.5 . 10{sup -4} . {rho} + 2 . 10{sup -3} kg . m{sup -3}) (coverage factor k = 2), the uncertainty in temperature T is estimated to be 0.006 K (coverage factor k = 2), and the uncertainty in pressure p is estimated to be 1 . 10{sup -4}.p (coverage factor k = 2). The equipment has been previously checked with pure nitrogen over the whole temperature and pressure working ranges and experimental results (35 values) are given and a comparison with the reference equation of state for nitrogen is presented.

  9. Recombination in deuterium plasma at cryogenic temperatures (down to 130 K)

    Energy Technology Data Exchange (ETDEWEB)

    Novotny, O.; Glosik, J.; Pysanenko, A.; Zakouril, P.; Plasil, R.; Tichy, M. [Prague Charles Univ., Faculty of Mathematics and Physics (Czech Republic)

    2004-07-01

    The ions H{sub 3}{sup +} and D{sub 3}{sup +} play an important role in the kinetics of media of astrophysical interest but also in laboratory produced plasmas (discharges, fusion plasmas). In the presented study variable temperature flowing afterglow with Langmuir probe (VT-FALP) was used to study plasma decay in D{sub 2}/He mixture at temperatures down to 130 K and total pressure up to 10 Torr. Large extend of partial number densities of D{sub 2} (10{sup 12} - 3 x 10{sup 15} cm{sup -3}) were used in the experiments. Langmuir probes and mass spectrometers were applied to monitor decay of the plasma during the afterglow. The study is a continuation of our previous measurements of recombination rate coefficients of D{sub 3}{sup +} and D{sub 5}{sup +} ions. In these studies we observed dependence of the recombination rate coefficient on partial pressure of deuterium indicating that third-body assisted recombination is efficient and significantly contributes to recombination in decaying deuterium-containing plasma. (authors)

  10. Partial molar volumes of (acetonitrile + water) mixtures over the temperature range (273.15 to 318.15) K

    International Nuclear Information System (INIS)

    Yeow, Y. Leong; Leong, Yee-Kwong

    2007-01-01

    Isothermal molar volume data of (acetonitrile + water) mixtures, between T = 273.15 K and T = 318.15 K, extracted from different sources are combined and treated as a single set to even out minor differences between sources and to increase the number of data points for each temperature. Tikhonov regularization is applied to compute the isothermal first and second derivatives of these data with respect to molar composition. For the reference temperature of 298.15 K, this computation is extended to the third derivative. Generalized Cross Validation is used to guide the selection of the regularization parameter that keeps noise amplification under control. The resulting first derivatives are used to construct the partial molar volume curves which are then checked against published results. Properties of the partial molar volumes are analysed by examining their derivatives. Finally the general shape of the second derivative curve of molar volume is explained qualitatively in terms of tripartite segmentation of the molar composition interval but quantitative comparisons are required to confirm this explanation

  11. Highly efficient low color temperature organic LED using blend carrier modulation layer

    Science.gov (United States)

    Hsieh, Yao-Ching; Chen, Szu-Hao; Shen, Shih-Ming; Wang, Ching-Chiun; Chen, Chien-Chih; Jou, Jwo-Huei

    2012-10-01

    Color temperature (CT) of light has great effect on human physiology and psychology, and low CT light, minimizing melatonin suppression and decreasing the risk of breast, colorectal, and prostate cancer. We demonstrates the incorporation of a blend carrier modulation interlayer (CML) between emissive layers to improve the device performance of low CT organic light emitting diodes, which exhibits an external quantum efficiency of 22.7% and 36 lm W-1 (54 cd A-1) with 1880 K at 100 cd m-2, or 20.8% and 29 lm W-1 (50 cd A-1) with 1940 K at 1000 cd m-2. The result shows a CT much lower than that of incandescent bulbs, which is 2500 K with 15 lmW-1 efficiency, and even as low as that of candles, which is 2000 K with 0.1 lmW-1. The high efficiency of the proposed device may be attributed to its CML, which helps effectively distribute the entering carriers into the available recombination zones.

  12. Volumetric properties of glucose in aqueous HCI solutions at temperatures from 278.15 to 318.15 K

    Institute of Scientific and Technical Information of China (English)

    ZHUO Kelei; ZHANG Qiufen; XUAN Xiaopeng; ZHANG Hucheng; WANG Jianji

    2007-01-01

    Densities have been measured for Glucose+HC1 +Water at 10-degree intervals from 278.15 to 318.15 K.The apparent molar volumes (Vφ,G) and standard partial molar volumes (V0φ,G) for Glucose in aqueous solution of 0.2,0.4,0.7,1.1,1.6,2.1 mol.kg-1 HCI have been calculated as well as volumetric interaction parameters (VEG) for Glucose-HC1 in water and standard partial molar expansion coefficients ((e)V0φ,G/(e)T)p.Results show that (1) the apparent molar volume for Glucose in aqueous HC1 solutions increases lineally with increasing molality of Glucose and HC1; (2) V0φ,Gfor Glucose in aqueous HC1 solutions increases lineally with increasing molality of HC1; (3) the volumetric interaction parameters for Glucose-HC1 pair in water are small positive and vary slightly with temperature; (4) the relation between V0φ,G and temperature exists as V0φ,G =α0+α1(T-273.15 K)2/3;(5)values of((e)V0φ,G/(e)T)p are positive and increase as temperatures rise,and at given temperatures decrease slightly with increasing molalities of HC1,indicating that the hydration of glucose decreases with increasing temperature and molality of HCI.These phenomena are interpreted successfully by the structure interaction model.

  13. Westinghouse AP 1000 program status

    International Nuclear Information System (INIS)

    Doehnert, B.

    2002-01-01

    The project 1000 is presented and features are discussed in the paper. Design maturity is characterized by 1300 man-year / $400 million design and testing effort, more than 12 000 design documents completed; 3D computer model developed. It includes structures, equipment, small / large pipe, cable trays, ducts etc. Licensing Maturity is determined by a very thorough and complete NRC review of AP600; 110 man-year effort (NRC) over 6 years, $30 million; independent, confirmatory plant analysis; independent, confirmatory plant testing (ROSA, OSU); over 7400 questions answered, no open items; over 380 meeting with NRC, 43 meetings with ACRS. NRC Design Certification is issued in December 1999. Reasons for developing AP 1000 and design changes are presented. Economic analysis shows an expectation for payback within 20 years. AP1000 provides 75% power uprate for 15% increment in capital cost. AP1000 meets new plant economic targets in the near term

  14. Importance of finite-temperature exchange correlation for warm dense matter calculations.

    Science.gov (United States)

    Karasiev, Valentin V; Calderín, Lázaro; Trickey, S B

    2016-06-01

    The effects of an explicit temperature dependence in the exchange correlation (XC) free-energy functional upon calculated properties of matter in the warm dense regime are investigated. The comparison is between the Karasiev-Sjostrom-Dufty-Trickey (KSDT) finite-temperature local-density approximation (TLDA) XC functional [Karasiev et al., Phys. Rev. Lett. 112, 076403 (2014)PRLTAO0031-900710.1103/PhysRevLett.112.076403] parametrized from restricted path-integral Monte Carlo data on the homogeneous electron gas (HEG) and the conventional Monte Carlo parametrization ground-state LDA XC [Perdew-Zunger (PZ)] functional evaluated with T-dependent densities. Both Kohn-Sham (KS) and orbital-free density-functional theories are used, depending upon computational resource demands. Compared to the PZ functional, the KSDT functional generally lowers the dc electrical conductivity of low-density Al, yielding improved agreement with experiment. The greatest lowering is about 15% for T=15 kK. Correspondingly, the KS band structure of low-density fcc Al from the KSDT functional exhibits a clear increase in interband separation above the Fermi level compared to the PZ bands. In some density-temperature regimes, the deuterium equations of state obtained from the two XC functionals exhibit pressure differences as large as 4% and a 6% range of differences. However, the hydrogen principal Hugoniot is insensitive to the explicit XC T dependence because of cancellation between the energy and pressure-volume work difference terms in the Rankine-Hugoniot equation. Finally, the temperature at which the HEG becomes unstable is T≥7200 K for the T-dependent XC, a result that the ground-state XC underestimates by about 1000 K.

  15. Vibrational spectrum of the K-590 intermediate in the bacteriorhodopsin photocycle at room temperature: picosecond time-resolved resonance coherent anti-Raman spectroscopy

    Science.gov (United States)

    Ujj, L.; Jäger, F.; Popp, A.; Atkinson, G. H.

    1996-12-01

    The vibrational spectrum of the K-590 intermediate, thought to contribute significantly to the energy storage and transduction mechanism in the bacteriorhodopsin (BR) photocycle, is measured at room temperature using picosecond time-resolved resonance coherent anti-Stokes Raman scattering (PTR/CARS). The room-temperature BR photocycle is initiated by the 3 ps, 570 nm excitation of the ground-state species, BR-570, prepared in both H 2O and D 2O suspensions of BR. PTR/CARS data, recorded 50 ps after BR-570 excitation, at which time only BR-570 and K-590 are present, have an excellent S/N which provides a significantly more detailed view of the K-590 vibrational degrees of freedom than previously available. Two picosecond (6 ps FWHM) laser pulses, ω1 (633.4 nm) and ωS (675-700 nm), are used to record PTR/CARS data via electronic resonance enhancement in both BR-570 and K-590, each of which contains a distinct retinal structure (assigned as 13- rans, 15- anti, 13- cis, respectively). To obtain the vibrational spectrum of K-590 separately, the PTR/CARS spectra from the mixture of isomeric retinals is quantitatively analyzed in terms of third-order susceptibility ( η(3)) relationships. PTR/CARS spectra of K-590 recorded from both H 2O and D 2O suspensions of BR are compared with the analogous vibrational data obtained via spontaneous resonance Raman (RR) scattering at both low (77 K) and room temperature. Analyses of these vibrational spectra identify temperature-dependent effects and changes assignable to the substitution of deuterium at the Schiff-base nitrogen not previously reported.

  16. STELLAR DIAMETERS AND TEMPERATURES. III. MAIN-SEQUENCE A, F, G, AND K STARS: ADDITIONAL HIGH-PRECISION MEASUREMENTS AND EMPIRICAL RELATIONS

    International Nuclear Information System (INIS)

    Boyajian, Tabetha S.; Jones, Jeremy; White, Russel; McAlister, Harold A.; Gies, Douglas; Von Braun, Kaspar; Van Belle, Gerard; Farrington, Chris; Schaefer, Gail; Ten Brummelaar, Theo A.; Sturmann, Laszlo; Sturmann, Judit; Turner, Nils H.; Goldfinger, P. J.; Vargas, Norm; Ridgway, Stephen

    2013-01-01

    Based on CHARA Array measurements, we present the angular diameters of 23 nearby, main-sequence stars, ranging from spectral types A7 to K0, 5 of which are exoplanet host stars. We derive linear radii, effective temperatures, and absolute luminosities of the stars using Hipparcos parallaxes and measured bolometric fluxes. The new data are combined with previously published values to create an Angular Diameter Anthology of measured angular diameters to main-sequence stars (luminosity classes V and IV). This compilation consists of 125 stars with diameter uncertainties of less than 5%, ranging in spectral types from A to M. The large quantity of empirical data is used to derive color-temperature relations to an assortment of color indices in the Johnson (BVR J I J JHK), Cousins (R C I C ), Kron (R K I K ), Sloan (griz), and WISE (W 3 W 4 ) photometric systems. These relations have an average standard deviation of ∼3% and are valid for stars with spectral types A0-M4. To derive even more accurate relations for Sun-like stars, we also determined these temperature relations omitting early-type stars (T eff > 6750 K) that may have biased luminosity estimates because of rapid rotation; for this subset the dispersion is only ∼2.5%. We find effective temperatures in agreement within a couple of percent for the interferometrically characterized sample of main-sequence stars compared to those derived via the infrared flux method and spectroscopic analysis.

  17. AP1000{sup TM} plant modularization

    Energy Technology Data Exchange (ETDEWEB)

    Cantarero L, C.; Demetri, K. J. [Westinghouse Electric Co., 1000 Westinghouse Drive, Cranberry Township, PA 16066 (United States); Quintero C, F. P., E-mail: cantarc@westinghouse.com [Westinghouse Electric Spain, Padilla 17, 28006 Madrid (Spain)

    2016-09-15

    The AP1000{sup TM} plant is an 1100 M We pressurized water reactor (PWR) with passive safety features and extensive plant simplifications that enhance construction, operation, maintenance and safety. Modules are used extensively in the design of the AP1000 plant nuclear island. The AP1000 plant uses modern, modular-construction techniques for plant construction. The design incorporates vendor-designed skids and equipment packages, as well as large, multi-ton structural modules and special equipment modules. Modularization allows traditionally sequential construction tasks to be completed simultaneously. Factory-built modules can be installed at the site in a planned construction schedule. The modularized AP1000 plant allows many more construction activities to proceed in parallel. This reduces plant construction calendar time, thus lowering the costs of plant financing. Furthermore, performing less work onsite significantly reduces the amount of skilled field-craft labor, which costs more than shop labor. In addition to labor cost savings, doing more welding and fabrication in a factory environment raises the quality of work, allowing more scheduling flexibility and reducing the amount of specialized tools required onsite. The site layout for the AP1000 plant has been established to support modular construction and efficient operations during construction. The plant layout is compact, using less space than previous conventional plant layouts. This paper provides and overview of the AP1000 plant modules with an emphasis on structural modules. Currently the Westinghouse AP1000 plant has four units under construction in China and four units under construction in the United States. All have shown successful fabrication and installation of various AP1000 plant modules. (Author)

  18. AP1000"T"M plant modularization

    International Nuclear Information System (INIS)

    Cantarero L, C.; Demetri, K. J.; Quintero C, F. P.

    2016-09-01

    The AP1000"T"M plant is an 1100 M We pressurized water reactor (PWR) with passive safety features and extensive plant simplifications that enhance construction, operation, maintenance and safety. Modules are used extensively in the design of the AP1000 plant nuclear island. The AP1000 plant uses modern, modular-construction techniques for plant construction. The design incorporates vendor-designed skids and equipment packages, as well as large, multi-ton structural modules and special equipment modules. Modularization allows traditionally sequential construction tasks to be completed simultaneously. Factory-built modules can be installed at the site in a planned construction schedule. The modularized AP1000 plant allows many more construction activities to proceed in parallel. This reduces plant construction calendar time, thus lowering the costs of plant financing. Furthermore, performing less work onsite significantly reduces the amount of skilled field-craft labor, which costs more than shop labor. In addition to labor cost savings, doing more welding and fabrication in a factory environment raises the quality of work, allowing more scheduling flexibility and reducing the amount of specialized tools required onsite. The site layout for the AP1000 plant has been established to support modular construction and efficient operations during construction. The plant layout is compact, using less space than previous conventional plant layouts. This paper provides and overview of the AP1000 plant modules with an emphasis on structural modules. Currently the Westinghouse AP1000 plant has four units under construction in China and four units under construction in the United States. All have shown successful fabrication and installation of various AP1000 plant modules. (Author)

  19. Maximum Efficiency of Thermoelectric Heat Conversion in High-Temperature Power Devices

    Directory of Open Access Journals (Sweden)

    V. I. Khvesyuk

    2016-01-01

    Full Text Available Modern trends in development of aircraft engineering go with development of vehicles of the fifth generation. The features of aircrafts of the fifth generation are motivation to use new high-performance systems of onboard power supply. The operating temperature of the outer walls of engines is of 800–1000 K. This corresponds to radiation heat flux of 10 kW/m2 . The thermal energy including radiation of the engine wall may potentially be converted into electricity. The main objective of this paper is to analyze if it is possible to use a high efficiency thermoelectric conversion of heat into electricity. The paper considers issues such as working processes, choice of materials, and optimization of thermoelectric conversion. It presents the analysis results of operating conditions of thermoelectric generator (TEG used in advanced hightemperature power devices. A high-temperature heat source is a favorable factor for the thermoelectric conversion of heat. It is shown that for existing thermoelectric materials a theoretical conversion efficiency can reach the level of 15–20% at temperatures up to 1500 K and available values of Ioffe parameter being ZT = 2–3 (Z is figure of merit, T is temperature. To ensure temperature regime and high efficiency thermoelectric conversion simultaneously it is necessary to have a certain match between TEG power, temperature of hot and cold surfaces, and heat transfer coefficient of the cooling system. The paper discusses a concept of radiation absorber on the TEG hot surface. The analysis has demonstrated a number of potentialities for highly efficient conversion through using the TEG in high-temperature power devices. This work has been implemented under support of the Ministry of Education and Science of the Russian Federation; project No. 1145 (the programme “Organization of Research Engineering Activities”.

  20. High-temperature Brillouin scattering study of haplogranitic glasses and liquids: Effects of F, K, Na and Li on Tg and elastic properties

    Science.gov (United States)

    Manghnani, M. H.; Hushur, A.; Williams, Q. C.; Dingwell, D. B.

    2010-12-01

    The density, compressibility and viscosity of silicate melts are important in understanding the thermodynamic and fluid dynamic properties of magmatic systems. Knowledge of the compressibility of silicate melts at 1 bar is an important component in the construction of accurate pressure-volume-temperature equations of state. In light of this, the velocity (nVp, Vp, Vs) and refractive index n of four anhydrous haplogranitic glasses and liquids with similar alkali abundances, but different cations, are measured at high temperature by Brillouin scattering spectroscopy through the glass transition temperature (Tg) in both platelet and back scattering geometry. The compositions of four haplogranites are 5 wt% of the components Li2O, Na2O, K2O and F each added to a base of haplogranitic (HPG8) composition. The glass transition temperature Tg of different haplogranite samples at the GHz frequency of the Brillouin probe are determined from the change in slope of the temperature-dependent longitudinal or transverse sound velocity. HPG8-Li5 has the lowest glass transition temperature (466°C), while HPG8-K5 has the highest glass transition temperature (575°C). Our Brillouin results, when compared with DSC measurements, show lower Tg values. This raises the possibility of a role of either heating rates or a frequency dependence of the glass transition in explaining the discrepancies in Tg values derived from the two methods. The sound velocity (nVp, Vp, Vs) shows markedly different temperature dependences (including differences in sign) below Tg depending on their different alkali contents. The unrelaxed elastic moduli of three haplogranitic glasses with added Li2O, Na2O and F components have been obtained as a function of temperature. The unrelaxed bulk modulus, shear modulus and Poisson’s ratio show strong compositional dependences at ambient temperature. On heating, The K initially decreases with increasing temperature up to ~ 135°C, then increases up to Tg, and then

  1. MgO melting curve constraints from shock temperature and rarefaction overtake measurements in samples preheated to 2300 K

    Science.gov (United States)

    Fat'yanov, O. V.; Asimow, P. D.

    2014-05-01

    Continuing our effort to obtain experimental constraints on the melting curve of MgO at 100-200 GPa, we extended our target preheating capability to 2300 K. Our new Mo capsule design holds a long MgO crystal in a controlled thermal gradient until impact by a Ta flyer launched at up to 7.5 km/s on the Caltech two-stage light-gas gun. Radiative shock temperatures and rarefaction overtake times were measured simultaneously by a 6-channel VIS/NIR pyrometer with 3 ns time resolution. The majority of our experiments showed smooth monotonic increases in MgO sound speed and shock temperature with pressure from 197 to 243 GPa. The measured temperatures as well as the slopes of the pressure dependences for both temperature and sound speed were in good agreement with those calculated numerically for the solid phase at our peak shock compression conditions. Most observed sound speeds, however, were ~800 m/s higher than those predicted by the model. A single unconfirmed data point at 239 GPa showed anomalously low temperature and sound speed, which could both be explained by partial melting in this experiment and could suggest that the Hugoniot of MgO preheated to 2300 K crosses its melting line just slightly above 240 GPa.

  2. MgO melting curve constraints from shock temperature and rarefaction overtake measurements in samples preheated to 2300 K

    International Nuclear Information System (INIS)

    Fat'yanov, O V; Asimow, P D

    2014-01-01

    Continuing our effort to obtain experimental constraints on the melting curve of MgO at 100-200 GPa, we extended our target preheating capability to 2300 K. Our new Mo capsule design holds a long MgO crystal in a controlled thermal gradient until impact by a Ta flyer launched at up to 7.5 km/s on the Caltech two-stage light-gas gun. Radiative shock temperatures and rarefaction overtake times were measured simultaneously by a 6-channel VIS/NIR pyrometer with 3 ns time resolution. The majority of our experiments showed smooth monotonic increases in MgO sound speed and shock temperature with pressure from 197 to 243 GPa. The measured temperatures as well as the slopes of the pressure dependences for both temperature and sound speed were in good agreement with those calculated numerically for the solid phase at our peak shock compression conditions. Most observed sound speeds, however, were ∼800 m/s higher than those predicted by the model. A single unconfirmed data point at 239 GPa showed anomalously low temperature and sound speed, which could both be explained by partial melting in this experiment and could suggest that the Hugoniot of MgO preheated to 2300 K crosses its melting line just slightly above 240 GPa.

  3. Generation of live offspring from vitrified embryos with synthetic polymers SuperCool X-1000 and SuperCool Z-1000.

    Science.gov (United States)

    Marco-Jimenez, F; Jimenez-Trigos, E; Lavara, R; Vicente, J S

    2014-01-01

    Ice growth and recrystallisation are considered important factors in determining vitrification outcomes. Synthetic polymers inhibit ice formation during cooling or warming of the vitrification process. The aim of this study was to assess the effect of adding commercially available synthetic polymers SuperCool X-1000 and SuperCool Z-1000 to vitrification media on in vivo development competence of rabbit embryos. Four hundred and thirty morphologically normal embryos recovered at 72 h of gestation were used. The vitrification media contained 20% dimethyl sulphoxide and 20% ethylene glycol, either alone or in combination with 1% of SuperCool X-1000 and 1% SuperCool. Our results show that embryos can be successfully vitrified using SuperCool X-1000 and SuperCool Z-1000 and when embryos are transferred, live offspring can be successfully produced. In conclusion, our results demonstrated that we succeeded for the first time in obtaining live offspring after vitrification of embryos using SuperCool X-1000 and SuperCool Z-1000 polymers.

  4. Approximation of the thermometric characteristics of n- and p-GaAs thermodiodes in the 4.2-300 K temperature range and p-GaAs resistance thermometers in the 4.2-100 K temperature range

    International Nuclear Information System (INIS)

    Logvinenko, S.P.; Derbysheva, S.L.

    1978-01-01

    The investigation results are reported of various methods for approximating the calibration characteristics of technical resistance thermometers made from p-GaAs and of thermodiodes from n- p-GaAs. The following methods may by used for approximating thermometric characteristics and obtaining calibration tables: method of approximating function describing a physical model (P); method of power polynoms (PP); and the spline method (S). Studies of thermometric characteristics have been achieved in the 4.2-300 K temperature range for thermodiodes, and at 4.2-100 K for thermoresistances. The obtained data show that the use of the S and PP methods for describing monotonous thermometric characteristics of thermodiodes and thermoresistances is equivalent and leads to satisfactory results. Method S affords the best results for describing thermometric characteristics with specific features. The error in approximating thermometric characteristics by method S does not exceed 0.01 K

  5. Adiabats of quartz, coesite, olivine, and magnesium oxide to 50 kbar and 1000 K, and the adiabatic gradient in the Earth's mantle

    Science.gov (United States)

    Boehler, R.

    1982-07-01

    The adiabats of olivine, magnesium oxide, and quartz were measured up to 50kbar and 1000 K. An end-loaded piston-cylinder apparatus with an in situ pressure gauge and a very fine thermocouple was used to measure (∂T/∂P)s during adiabatic compression. A power law between (∂T/∂P)s and compression yields values of the power n = -∂ ln (∂T/∂P)s/∂ ln ρ that agree with previous results from salts, metals, and fluids. Assuming constant values for n, the adiabtic gradient for an olivine upper mantle and a magnesium oxide lower mantle was calculated. The results agree well with some previous theoretical estimates. The volume dependence of the Grüneisen parameter γ was calculated from the thermodynamic equation ∂ ln γ/∂ ln ρ = ∂B/∂P - n, where B is the isothermal bulk modulus. γ is found to a good approximation to be proportional to volume. Table 6 is available with entire article on microfiche. Order from American Geophysical Union, 2000 Florida Avenue, N.W., Washington, D.C. 20009. Document J82-002; $1.00. Payment must accompany order.

  6. Phase equilibrium measurements of (methane + benzene) and (methane + methylbenzene) at temperatures from (188 to 348) K and pressures to 13 MPa

    International Nuclear Information System (INIS)

    Hughes, Thomas J.; Kandil, Mohamed E.; Graham, Brendan F.; Marsh, Kenneth N.; Huang, Stanley H.; May, Eric F.

    2015-01-01

    Highlights: • VLE data for (CH 4 (1) + C 6 H 6 (2)) and (CH 4 (1) + C 6 H 5 CH 3 (3)) were measured. • LLE was observed at T = 198.15 K, a T higher than expected, for (CH 4 + C 6 H 5 CH 3 ) . • Inconsistences in the literature data were identified and assessed. • More data at x 1 > 0.3 for both systems are needed to investigate discrepancies. - Abstract: New isothermal pTxy data are reported for (methane + benzene) and (methane + methylbenzene (toluene)) at pressures up to 13 MPa over the temperature range (188 to 313) K using a custom-built (vapor + liquid) equilibrium (VLE) apparatus. The aim of this work was to investigate literature data inconsistencies and to extend the measurements to lower temperatures. For (methane (1) + benzene (2)), measurements were made along six isotherms from (233 to 348) K at pressures to 9.6 MPa. At temperatures below 279 K there was evidence of a solid phase, and thus only vapor phase samples were analyzed at these temperatures. For the (methane (1) + methylbenzene (3)) system, measurements were made along seven isotherms from T = (188 to 313) K at pressures up to 13 MPa. Along the 198 K isotherm, a significant change in the data’s p,x slope was observed indicating (liquid + liquid) equilibria at higher pressures. The data were compared with literature data and with calculations made using the Peng–Robinson (PR) equation of state (EOS). For both binary systems our data agree with much of the literature data that also deviate from the EOS in a similar manner. However, the data of Elbishlawi and Spencer (1951) for both binary systems, which appear to have received an equal weighting to other data in the EOS development, are inconsistent with the results of our measurements and data from other literature sources

  7. Development of powder metallurgy Al alloys for high temperature aircraft structural applications, phase 2

    Science.gov (United States)

    Chellman, D. J.

    1982-01-01

    In this continuing study, the development of mechanically alloyed heat resistant aluminum alloys for aircraft were studied to develop higher strength targets and higher service temperatures. The use of higher alloy additions to MA Al-Fe-Co alloys, employment of prealloyed starting materials, and higher extrusion temperatures were investigated. While the MA Al-Fe-Co alloys exhibited good retention of strength and ductility properties at elevated temperatures and excellent stability of properties after 1000 hour exposure at elevated temperatures, a sensitivity of this system to low extrusion strain rates adversely affected the level of strength achieved. MA alloys in the Al-Li family showed excellent notched toughness and property stability after long time exposures at elevated temperatures. A loss of Li during processing and the higher extrusion temperature 482 K (900 F) resulted in low mechanical strengths. Subsequent hot and cold working of the MA Al-Li had only a mild influence on properties.

  8. Comparison of MCNP calculations against measurements in moderator temperature experiments with CANFLEX-LEU in ZED-2

    International Nuclear Information System (INIS)

    Watts, D.G.; Adams, F.P.; Zeller, M.B.; Bromley, B.P.

    2008-01-01

    This paper summarizes sample calculations of MCNP5 compared against measurements of moderator temperature coefficient experiments in the ZED-2 critical facility with CANFLEX-LEU fuel. MCNP5 is tested for key parameters associated with various reactor physics phenomena of interest for CANDU/ACR-1000) reactors, including reactivity changes with coolant density, moderator density, and moderator temperature, and also normalized flux distributions. The experimental data for these comparisons were obtained from critical experiments in AECL's ZED-2 critical facility using CANFLEX-LEU fuel in a 24-cm square lattice pitch. These comparisons establish biases/uncertainties in the calculation of k-eff, coolant void reactivity, and moderator temperature coefficient of reactivity. Results show very little bias in the moderator temperature coefficient of reactivity, and very good agreement in the calculation of normalized flux distributions. (author)

  9. Lightweight, High-Temperature Radiator for Space Propulsion

    Science.gov (United States)

    Hyers, R. W.; Tomboulian, B. N.; Crave, Paul D.; Rogers, J. R.

    2012-01-01

    For high-power nuclear-electric spacecraft, the radiator can account for 40% or more of the power system mass and a large fraction of the total vehicle mass. Improvements in the heat rejection per unit mass rely on lower-density and higher-thermal conductivity materials. Current radiators achieve near-ideal surface radiation through high-emissivity coatings, so improvements in heat rejection per unit area can be accomplished only by raising the temperature at which heat is rejected. We have been investigating materials that have the potential to deliver significant reductions in mass density and significant improvements in thermal conductivity, while expanding the feasible range of temperature for heat rejection up to 1000 K and higher. The presentation will discuss the experimental results and models of the heat transfer in matrix-free carbon fiber fins. Thermal testing of other carbon-based fin materials including carbon nanotube cloth and a carbon nanotube composite will also be presented.

  10. Experimental and computational analysis of a 1.2 kW PEMFC designed for communications backup power applications

    International Nuclear Information System (INIS)

    Krishnan, K.J.; Claveria, J.; Varadharajan, L.; Kalam, A.

    2011-01-01

    Usage of Fuel Cells due to their high power density and low greenhouse gas emissions which combine H/sub 2/ and O/sub 2/ electrochemically to produce electricity and H/sub 2/O as the by-product will become widespread in the near future due to its quality, reliability and portability. Among all types of fuel cells, Proton Exchange Membrane Fuel Cells (PEMFC) is most attractive for residential and automotive industry use due to its low operating temperature, silent operation, quick start-up characteristics and better performance. The T-1000 1.2 kW PEMFC are mainly used for communications backup power applications because of its high reliability, simplicity and ease of maintenance in telecommunication sector, utility and government etc. This paper discuses the features of T- 1000 PEMFC and also the production losses due to power outages in US and different parts of the globe and the advantages of using it in different sectors to reduce the production loses occurred by the power outages. This work focuses on the experimental data and the computational data of load, P, V, A and H/sub 2/ consumed under laboratory conditions at Power Lab in Victoria University, Melbourne. The paper also describes various load, P, V and A curves recorded at regular intervals between the experimental and computational data. The work shows notably the benefit of using T-1000 1.2 kW PEMFC for residential, automobile, government and telecom sectors. (author)

  11. VVER-1000 backfitting programs

    International Nuclear Information System (INIS)

    Zabka, H.; Milhem, J.L.

    1998-01-01

    Russia, Ukraine, and Bulgaria have nineteen nuclear generating units of the VVER-1000/V-320 (1000 MWe PWR) type in operation. Most of these plants were built in the eighties. Their design is based on Soviet standards of the seventies. In the early eighties and, in particular, after the Chernobyl accident, new safety principles and supplementary specific standards were introduced. However, they were taken into account only to a limited extent in the design and construction of the VVER-1000/V-320 plants. A number of nuclear power plants, whose construction was stopped after the political changes in the countries of the former USSR, now are to be completed with the financial assistance of the Commission of the European Union and other Western organizations, respectively. This Western support is dependent on the condition that these plants attain a level of engineered safeguards comparable to that of PWR plants currently in operation in Western Europe. (orig.) [de

  12. A DLTS study of the evolution of oxygen precipitates in Si at high temperature and high pressure

    International Nuclear Information System (INIS)

    Antonova, I.V.; Popov, V.P.; Fedina, L.I.; Shaimeev, S.S.; Misiuk, A.

    1996-01-01

    The effect of high hydrostatic pressure on the dissolution of oxygen precipitates introduced beforehand into Si at temperatures of 920-1000 K (over period of 96 h) is investigated by the DLTS method. A measurement procedure, based on the formation of electrically active complexes (interstitial oxygen atom-vacancy) during electron irradiation of the samples, is proposed. It is shown that the precipitates do not decompose when point defects are introduced at room temperature. As the treatment temperature increases (to 1220-1650 K), for the same values of the hydrostatic pressure (up to 1.3 GPa) the intensity of the decomposition of oxygen precipitates increases and at 1650 K they are completely dissolved. Study of the decomposition kinetics showed that hydrostatic pressure raises the limit of solubility of the oxygen atoms Oi and slows down their diffusion. It is determined that the diffusion activation energy Ea, just as the preexponential factor D0, in the expression for the diffusion decrease with increasing hydrostatic pressure, resulting in a lower diffusion. Possible mechanisms for the effect of hydrostatic pressure on oxygen diffusion near a precipitate are discussed

  13. Vitamin K1 (phylloquinone) and K2 (menaquinone-4) supplementation improves bone formation in a high-fat diet-induced obese mice.

    Science.gov (United States)

    Kim, Misung; Na, Woori; Sohn, Cheongmin

    2013-09-01

    Several reports suggest that obesity is a risk factor for osteoporosis. Vitamin K plays an important role in improving bone metabolism. This study examined the effects of vitamin K1 and vitamin K2 supplementation on the biochemical markers of bone turnover and morphological microstructure of the bones by using an obese mouse model. Four-week-old C57BL/6J male mice were fed a 10% fat normal diet group or a 45% kcal high-fat diet group, with or without 200 mg/1000 g vitamin K1 (Normal diet + K1, high-fat diet + K1) and 200 mg/1000 g vitamin K2 (Normal diet + K2, high-fat diet + K2) for 12 weeks. Serum levels of osteocalcin were higher in the high-fat diet + K2 group than in the high-fat diet group. Serum OPG level of the high-fat diet group, high-fat diet + K1 group, and high-fat diet + K2 group was 2.31 ± 0.31 ng/ml, 2.35 ± 0.12 ng/ml, and 2.90 ± 0.11 ng/ml, respectively. Serum level of RANKL in the high-fat diet group was significantly higher than that in the high-fat diet + K1 group and high-fat diet + K2 group (p<0.05). Vitamin K supplementation seems to tend to prevent bone loss in high-fat diet induced obese state. These findings suggest that vitamin K supplementation reversed the high fat diet induced bone deterioration by modulating osteoblast and osteoclast activities and prevent bone loss in a high-fat diet-induced obese mice.

  14. Shut-down margin study for the next generation VVER-1000 reactor including 13 x 13 hexagonal annular assemblies

    International Nuclear Information System (INIS)

    Faghihi, Farshad; Mirvakili, S. Mohammad

    2011-01-01

    Highlights: → Shut-Down Margin (SDM) for the next generation annular fuel core of typical VVER-1000, 13 x 13 assemblies are calculated. → The MCNP-5 code is run for many cases with different core burn up at various core temperatures. → There is a substantial drop in SDM in the case of annular fuel for the same power level. → SDM for our proposed VVER-1000 annular pins is calculated for specific average fuel burn up values at the BOC, MOC, and EOC. - Abstract: Shut-Down Margin (SDM) for the next generation annular fuel core of typical VVER-1000, 13 x 13 assemblies are calculated as the main aim of the present research. We have applied the MCNP-5 code for many cases with different values of core burn up at various core temperatures, and therefore their corresponding coolant densities and boric acid concentrations. There is a substantial drop in SDM in the case of annular fuel for the same power level. Specifically, SDM for our proposed VVER-1000 annular pins is calculated when the average fuel burn up values at the BOC, MOC, and EOC are 0.531, 11.5, and 43 MW-days/kg-U, respectively.

  15. Effect of phylloquinone (vitamin K1) supplementation for 12 months on the indices of vitamin K status and bone health in adult patients with Crohn's disease.

    Science.gov (United States)

    O'Connor, Eibhlís M; Grealy, Geraldine; McCarthy, Jane; Desmond, Alan; Craig, Orla; Shanahan, Fergus; Cashman, Kevin D

    2014-10-14

    Although epidemiological findings support a role for vitamin K status in the improvement of bone indices in adult patients with Crohn's disease (CD), this needs to be confirmed in double-blind, randomised controlled trials (RCT) with phylloquinone (vitamin K1). By conducting two RCT, the present study aimed to first establish whether supplementation with 1000 μg of phylloquinone daily near-maximally suppresses the percentage of undercarboxylated osteocalcin in serum (%ucOC; marker of vitamin K status) in adult patients with CD currently in remission as it does in healthy adults and second determine the effect of supplementation with phylloquinone at this dose for 12 months on the indices of bone turnover and bone mass. The initial dose-ranging RCT was conducted in adult patients with CD (n 10 per group) using 0 (placebo), 1000 or 2000 μg of phylloquinone daily for 2 weeks. In the main RCT, the effect of placebo v. 1000 μg vitamin K/d (both co-administered with Ca (500 mg/d) and vitamin D3 (10 μg/d)) for 12 months (n 43 per group) on the biochemical indices of bone turnover (determined by enzyme immunoassay) and bone mass (determined by dual-energy X-ray absorptiometry) were investigated. At baseline, the mean %ucOC was 47 %, and this was suppressed upon supplementation with 1000 μg of phylloquinone daily ( - 81 %; P0·1) on bone turnover markers or on the bone mass of the lumbar spine or femur, but modestly increased (Pvitamin D3) had no effect on the indices of bone health in adult CD patients with likely vitamin K insufficiency.

  16. STELLAR DIAMETERS AND TEMPERATURES. III. MAIN-SEQUENCE A, F, G, AND K STARS: ADDITIONAL HIGH-PRECISION MEASUREMENTS AND EMPIRICAL RELATIONS

    Energy Technology Data Exchange (ETDEWEB)

    Boyajian, Tabetha S.; Jones, Jeremy; White, Russel; McAlister, Harold A.; Gies, Douglas [Center for High Angular Resolution Astronomy and Department of Physics and Astronomy, Georgia State University, P.O. Box 4106, Atlanta, GA 30302-4106 (United States); Von Braun, Kaspar [NASA Exoplanet Science Institute, California Institute of Technology, MC 100-22, Pasadena, CA 91125 (United States); Van Belle, Gerard [Lowell Observatory, Flagstaff, AZ 86001 (United States); Farrington, Chris; Schaefer, Gail; Ten Brummelaar, Theo A.; Sturmann, Laszlo; Sturmann, Judit; Turner, Nils H.; Goldfinger, P. J.; Vargas, Norm [CHARA Array, Mount Wilson Observatory, Mount Wilson, CA 91023 (United States); Ridgway, Stephen [National Optical Astronomy Observatory, P.O. Box 26732, Tucson, AZ 85726-6732 (United States)

    2013-07-01

    Based on CHARA Array measurements, we present the angular diameters of 23 nearby, main-sequence stars, ranging from spectral types A7 to K0, 5 of which are exoplanet host stars. We derive linear radii, effective temperatures, and absolute luminosities of the stars using Hipparcos parallaxes and measured bolometric fluxes. The new data are combined with previously published values to create an Angular Diameter Anthology of measured angular diameters to main-sequence stars (luminosity classes V and IV). This compilation consists of 125 stars with diameter uncertainties of less than 5%, ranging in spectral types from A to M. The large quantity of empirical data is used to derive color-temperature relations to an assortment of color indices in the Johnson (BVR{sub J} I{sub J} JHK), Cousins (R{sub C} I{sub C}), Kron (R{sub K} I{sub K}), Sloan (griz), and WISE (W{sub 3} W{sub 4}) photometric systems. These relations have an average standard deviation of {approx}3% and are valid for stars with spectral types A0-M4. To derive even more accurate relations for Sun-like stars, we also determined these temperature relations omitting early-type stars (T{sub eff} > 6750 K) that may have biased luminosity estimates because of rapid rotation; for this subset the dispersion is only {approx}2.5%. We find effective temperatures in agreement within a couple of percent for the interferometrically characterized sample of main-sequence stars compared to those derived via the infrared flux method and spectroscopic analysis.

  17. Rate constant measurements for the overall reaction of OH + 1-butanol → products from 900 to 1200 K.

    Science.gov (United States)

    Pang, Genny A; Hanson, Ronald K; Golden, David M; Bowman, Craig T

    2012-03-15

    The rate constant for the overall reaction OH + 1-butanol → products was determined in the temperature range 900 to 1200 K from measurements of OH concentration time histories in reflected shock wave experiments of tert-butyl hydroperoxide (TBHP) as a fast source of OH radicals with 1-butanol in excess. Narrow-linewidth laser absorption was employed for the quantitative OH concentration measurement. A detailed kinetic mechanism was constructed that includes updated rate constants for 1-butanol and TBHP kinetics that influence the near-first-order OH concentration decay under the present experimental conditions, and this mechanism was used to facilitate the rate constant determination. The current work improves upon previous experimental studies of the title rate constant by utilizing a rigorously generated kinetic model to describe secondary reactions. Additionally, the current work extends the temperature range of experimental data in the literature for the title reaction under combustion-relevant conditions, presenting the first measurements from 900 to 1000 K. Over the entire temperature range studied, the overall rate constant can be expressed in Arrhenius form as 3.24 × 10(-10) exp(-2505/T [K]) cm(3) molecule(-1) s(-1). The influence of secondary reactions on the overall OH decay rate is discussed, and a detailed uncertainty analysis is performed yielding an overall uncertainty in the measured rate constant of ±20% at 1197 K and ±23% at 925 K. The results are compared with previous experimental and theoretical studies on the rate constant for the title reaction and reasonable agreement is found when the earlier experimental data were reinterpreted.

  18. Calibration of thermometers in the range from 4K to 40K

    International Nuclear Information System (INIS)

    Cruz, M.E. de la; Sereni, Julian; Salva, Horacio.

    1977-06-01

    Carbon and Germanium resistors have been calibrated against a standard in the temperature range from 4K to 40K. From the data, values of temperature are obtained with 0,1% error (std deviation). These calibrations have been also checked against specific heat measurements. (author) [es

  19. {sup 14}C SIRI samples at CNA: Measurements at 200 kV and 1000 kV

    Energy Technology Data Exchange (ETDEWEB)

    Santos Arévalo, Francisco-Javier, E-mail: fj.santos@csic.es; Gómez Martínez, Isabel; Agulló García, Lidia

    2015-10-15

    The Sixth International Radiocarbon Intercomparison (SIRI) exercise has taken place during late 2013 and 2014. 13 samples were distributed for AMS (Accelerator Mass Spectrometry) and 5 for radiometric laboratories, including one sample exclusively for radiometric laboratories. Being the first opportunity for our laboratory to participate actively in an intercomparison exercise, we have prepared and measured the samples in the two existing AMS dedicated facilities at the Centro Nacional de Aceleradores (CNA): SARA (Spanish Accelerator for Radionuclide Analysis), a 1 MV multielemental AMS system from HVEE, and Micadas, a 200 kV radiocarbon dating system designed by ETH. Results are presented for the two systems, together with a description of both the sample preparation and measurement procedures.

  20. 7 CFR 1940.1000 - OMB control number.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 13 2010-01-01 2009-01-01 true OMB control number. 1940.1000 Section 1940.1000 Agriculture Regulations of the Department of Agriculture (Continued) RURAL HOUSING SERVICE, RURAL BUSINESS....1000 OMB control number. The collection of information requirements contained in this regulation has...

  1. Stratigraphic evidence of desertification in the west-central Great Plains within the past 1000 yr

    Science.gov (United States)

    Madole, R.F.

    1994-01-01

    Stratigraphic and geomorphic relations, archaeological data, and eight radiocarbon ages at five widely scattered localities in northeastern Colorado indicate that eolian sand was mobilized over broad areas within the past 1000 yr. The mobilization began after 1 ka, was episodic, and ended at some as yet undetermined time prior to the latter part of the 19th century. Given that climate-model simulations suggest only slight variation in average surface temperature and annual precipitation in this region during the past 1000 yr, this part of the Great Plains evidently is near the threshold of widespread eolian sand transport under the present climate. -Author

  2. 26 CFR 1.998-1.1000 - [Reserved

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 10 2010-04-01 2010-04-01 false [Reserved] 1.998-1.1000 Section 1.998-1.1000 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES Domestic International Sales Corporations §§ 1.998-1.1000 [Reserved] ...

  3. 7 CFR 4284.1000 - OMB control number.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 15 2010-01-01 2010-01-01 false OMB control number. 4284.1000 Section 4284.1000 Agriculture Regulations of the Department of Agriculture (Continued) RURAL BUSINESS-COOPERATIVE SERVICE AND RURAL UTILITIES SERVICE, DEPARTMENT OF AGRICULTURE GRANTS Value-Added Producer Grants § 4284.1000 OMB...

  4. Low temperature nitrogen chemistry. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Glarborg, P.; Dam-Johansen, K.; Kristensen, P.G.; Alzueta, M.; Roejel, H.

    1997-04-01

    The results of a two tasks program on Natural Gas Reburning are reported. The work involved an experimental and theoretical study of the reburning and hybrid reburning/SNCR chemistry in the 1000-1500 K range. The interactions between hydrocarbon and nitrogen chemistry under fuel-rich conditions were investigated in order to assess the NO{sub x} reduction potential of low temperature reburning. The effect of reburn fuel(carbon monoxide, methane, acetylene, ethylene, ethane, and methane/ethane mixture), temperature, stoichiometry, reactant dilution, reaction time, and inlet NO level were studied. The results indicate a significant NO reduction potential even below 1400 K, but extrapolation to practical conditions are complicated by inadequate knowledge of the detailed chemistry as well as of the effect of mixing. The possibilities of enhancing the conversion to N{sub 2} instead of NO by adding selective reducing agents (hybrid reburning/SNCR) were evaluated. Our results indicate little synergistic effect between reburn and SNCR. The most simple configuration, where the selective reducing agent is injected together with the burnout air, is not expected to be effective, unless the N-agent is injected in form of an aqueous solution. A chemical kinetic model for reburning and reburn/SNCR is listed and can be obtained by e-mail from pgl(commerical at)kt.dtu.dk.(au) 145 refs.

  5. Determination of in-service change in the geometry of WWER-1000 core baffle: Calculations and measurements

    International Nuclear Information System (INIS)

    Margolin, B.Z.; Varovin, A.Y.; Minkin, A.J.; Sorokin, A.A.; Piminov, V.A.; Evdokimenko, V.V.; Fedosovsky, M.E.; Sherstobitov, A.E.; Ovchinnikov, A.G.; Pikulik, S.S.; Erak, D.Y.; Bobkov, A.V.; Timofeev, A.M.; Timokhin, V.I.; Yakushev, S.V.; Vasiliev, V.G.

    2015-01-01

    The paper gives the basic constitutive equations describing radiation swelling and creep depending on neutron dose, irradiation temperature and triaxial stress state, and justifies these equations experimentally. The WWER-1000 core baffle change in geometry was calculated by different models describing the effect of stresses on radiation swelling. The calculated results are compared with the measured ones for the operating WWER-1000 core baffle at the Balakovo NPP, Unit 1. A method of individual prediction of core baffle geometry change on the basis of the measurement results has been proposed. (authors)

  6. Mass- and energy-analysis of fast ion beams in PF-1000 by means of a Thomson spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Czaus, K.; Skladnik-Sadowska, E.; Malinowski, K.; Kwiatkowski, R.; Zebrowski, J. [The Andrzej Soltan Institute for Nuclear Studies - IPJ, 05-400 Otwock-Swierk (Poland); Sadowski, M.J. [The Andrzej Soltan Institute for Nuclear Studies - IPJ, 05-400 Otwock-Swierk (Poland)] [Institute of Plasma Physics and Laser Microfusion - IPPLM, 01-497 Warsaw (Poland); Zebrowski, J.; Karpinski, L.; Paduch, M.; Scholz, M.; Zielinska, E. [Institute of Plasma Physics and Laser Microfusion - IPPLM, 01-497 Warsaw (Poland); Garkusha, I.E. [Institute of Plasma Physics, NSC KIPT, 61-108 Kharkov (Ukraine)

    2011-07-01

    The paper describes measurements of energy spectra of ions emitted along the z-axis of the PF-1000 facility, which have been for the first time performed by means a miniature Thomson spectrometer during 480-kJ discharges with the deuterium filling. The recorded Thomson parabolas showed that the escaping deuterons have energies in the range of 25-1000 keV, while protons (originated from hydrogen remnants) have the population of about 2 orders smaller and energies within the range of 35-300 keV. This document is composed of a paper followed by a poster. (authors)

  7. Phase transition temperatures of 405-725 K in superfluid ultra-dense hydrogen clusters on metal surfaces

    International Nuclear Information System (INIS)

    Holmlid, Leif; Kotzias, Bernhard

    2016-01-01

    Ultra-dense hydrogen H(0) with its typical H-H bond distance of 2.3 pm is superfluid at room temperature as expected for quantum fluids. It also shows a Meissner effect at room temperature, which indicates that a transition point to a non-superfluid state should exist above room temperature. This transition point is given by a disappearance of the superfluid long-chain clusters H_2_N(0). This transition point is now measured for several metal carrier surfaces at 405 - 725 K, using both ultra-dense protium p(0) and deuterium D(0). Clusters of ordinary Rydberg matter H(l) as well as small symmetric clusters H_4(0) and H_3(0) (which do not give a superfluid or superconductive phase) all still exist on the surface at high temperature. This shows directly that desorption or diffusion processes do not remove the long superfluid H_2_N(0) clusters. The two ultra-dense forms p(0) and D(0) have different transition temperatures under otherwise identical conditions. The transition point for p(0) is higher in temperature, which is unexpected.

  8. A Neutronic Feasibility Study of an OPR-1000 Core Design with Boron-bearing Fuel

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kyung Hoon; Park, Sang Yoon; Lee, Chung Chan; Yang, Yong Sik [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2013-10-15

    In Westinghouse plants, boron is mainly used as a form of the integral fuel burnable absorber (IFBA) with a thin coating of zirconium diboride (ZrB{sub 2}) or wet annular burnable absorber (WABA) with a hollow Al{sub 2}O{sub 3}+B{sub 4}C pellet. In OPR-1000, on the other hand, gadolinia is currently employed as a form of an admixture which consists of Gd{sub 2}O{sub 3} of 6∼8 w/o and UO{sub 2} of natural uranium. Recently, boron-bearing UO{sub 2} fuel (BBF) with the high density of greater than 94%TD has been developed by using a low temperature sintering technique. In this paper, the feasibility of replacing conventional gadolinia-bearing UO{sub 2} fuel (GBF) in OPR-1000 with newly developed boron-bearing fuel is evaluated. Neutronic feasibility study to utilize the BBF in OPR-1000 core has been performed. The results show that the OPR-1000 core design with the BBF is feasible and promising in neutronic aspects. Therefore, the use of the BBF in OPR-1000 can reduce the dependency on the rare material such as gadolinium. However, the burnout of the {sup 10}B isotope results in helium gas, so fuel performance related study with respect to helium generation is needed.

  9. Observing electron spin resonance between 0.1 and 67 GHz at temperatures between 50 mK and 300 K using broadband metallic coplanar waveguides

    Science.gov (United States)

    Wiemann, Yvonne; Simmendinger, Julian; Clauss, Conrad; Bogani, Lapo; Bothner, Daniel; Koelle, Dieter; Kleiner, Reinhold; Dressel, Martin; Scheffler, Marc

    2015-05-01

    We describe a fully broadband approach for electron spin resonance (ESR) experiments, where it is possible to tune not only the magnetic field but also the frequency continuously over wide ranges. Here, a metallic coplanar transmission line acts as compact and versatile microwave probe that can easily be implemented in different cryogenic setups. We perform ESR measurements at frequencies between 0.1 and 67 GHz and at temperatures between 50 mK and room temperature. Three different types of samples (Cr3+ ions in ruby, organic radicals of the nitronyl-nitroxide family, and the doped semiconductor Si:P) represent different possible fields of application for the technique. We demonstrate that an extremely large phase space in temperature, magnetic field, and frequency for ESR measurements, substantially exceeding the range of conventional ESR setups, is accessible with metallic coplanar lines.

  10. Low-Temperature Dynamic Nuclear Polarization at 9.4 Tesla With a 30 Milliwatt Microwave Source

    Science.gov (United States)

    Thurber, Kent R.; Yau, Wai-Ming; Tycko, Robert

    2010-01-01

    Dynamic nuclear polarization (DNP) can provide large signal enhancements in nuclear magnetic resonance (NMR) by transfer of polarization from electron spins to nuclear spins. We discuss several aspects of DNP experiments at 9.4 Tesla (400 MHz resonant frequency for 1H, 264 GHz for electron spins in organic radicals) in the 7–80 K temperature range, using a 30 mW, frequency-tunable microwave source and a quasi-optical microwave bridge for polarization control and low-loss microwave transmission. In experiments on frozen glycerol/water doped with nitroxide radicals, DNP signal enhancements up to a factor of 80 are observed (relative to 1H NMR signals with thermal equilibrium spin polarization). The largest sensitivity enhancements are observed with a new triradical dopant, DOTOPA-TEMPO. Field modulation with a 10 G root-mean-squared amplitude during DNP increases the nuclear spin polarizations by up to 135%. Dependencies of 1H NMR signal amplitudes, nuclear spin relaxation times, and DNP build-up times on the dopant and its concentration, temperature, microwave power, and modulation frequency are reported and discussed. The benefits of low-temperature DNP can be dramatic: the 1H spin polarization is increased approximately 1000-fold at 7 K with DNP, relative to thermal polarization at 80 K. PMID:20392658

  11. In situ XRD study of C60 polymerisation above pressures of 9 GPa and temperatures up to 830K

    International Nuclear Information System (INIS)

    Talyzin, A.V.; Jansson, U.; Dubrovinsky, L.S.; Oden, M.; Le Bihan, T.

    2002-01-01

    The C60 polymerization was studied by X-ray diffraction in situ in the pressure range 13-18 GPa and at temperatures up to 830 K. The results of the high pressure high temperature treatment are strongly dependent from the history of the sample and stress. At certain conditions no elliptical diffraction patterns were observed at 13 GPa and 830K. Samples with a relatively low internal stress showed a transformation to new phase. It is suggested that this phase is three-dimensional polymer with each C60 molecule bonded to eight neighbors. This phase showed an increased hardness (about 37 GPa) and a Raman spectrum distinctly different from previously known polymeric phases

  12. Bi-Sr-Ca-Cu-O superconductor system with critical temperatures of 80 and 107 K

    International Nuclear Information System (INIS)

    Kugimiya, K.; Kawashima, S.; Inoue, O.; Adachi, S.

    1988-01-01

    Critical temperatures (T/sub c/) of 80 and 107 K are confirmed by resistivity and inductance measurements and also by the Meissner effect. X-rayelectron diffraction and electron microscopy analyses on a single phase material of 80 K show that its structure is orthorhombic with a unit cell of a = 5.407 A, b = 27.011 A, c = 30.588 A composed of a pseudotetragonal cell of a = b = 5.41 A. The pseudotetragonal cell size and cleavage behavior to very thin flakes strongly indicate that the oxide is basically a lamellar oxide of the Aurivillius phase type, i.e., a stacked layer structure of (Bi 2 O 2 ) 2+ sheets and distorted perovskite cell sheets

  13. OECD/DOE/CEA VVER-1000 coolant transient (V1000CT) benchmark for assessing coupled neutronics/thermal-hydraulics system codes for VVER-1000 RIA analysis

    International Nuclear Information System (INIS)

    Ivanov, B.; Ivanov, K.; Aniel, S.; Royer, E.; Kolev, N.; Groudev, P.

    2004-01-01

    The present paper describes the two phases of the OECD/DOE/CEA VVER-1000 coolant transient benchmark labeled as V1000CT. This benchmark is based on a data from the Bulgarian Kozloduy NPP Unit 6. The first phase of the benchmark was designed for the purpose of assessing neutron kinetics and thermal-hydraulic modeling for a VVER-1000 reactor, and specifically for their use in analyzing reactivity transients in a VVER-1000 reactor. Most of the results of Phase 1 will be compared against experimental data and the rest of the results will be used for code-to-code comparison. The second phase of the benchmark is planned for evaluation and improvement of the mixing computational models. Code-to-code and code-to-data comparisons will be done based on data of a mixing experiment conducted at Kozloduy-6. Main steam line break will be also analyzed in the second phase of the V1000CT benchmark. The results from it will be used for code-to-code comparison. The benchmark team has been involved in analyzing different aspects and performing sensitivity studies of the different benchmark exercises. The paper presents a comparison of selected results, obtained with two different system thermal-hydraulics codes, with the plant data for the Exercise 1 of Phase 1 of the benchmark as well as some results for Exercises 2 and 3. Overall, this benchmark has been well accepted internationally, with many organizations representing 11 countries participating in the first phase of the benchmark. (authors)

  14. The thermal expansion of a highly crystalline hexagonal BC2N compound synthesized under high temperature and pressure

    International Nuclear Information System (INIS)

    Wu Qinghua; Liu Zhongyuan; Hu Qianku; Li Hui; He Julong; Yu Dongli; Li Dongchun; Tian Yongjun

    2006-01-01

    The thermal expansion has been investigated for a highly crystalline hexagonal BC 2 N compound synthesized by the compression of a turbostratic B-C-N precursor with iron catalyst at the high temperature of 1500 deg. C and the high pressure of 5.5 GPa. The thermal expansion in the c direction is large and linear with an expansion coefficient of 35.86 x 10 -6 K -1 up to 1000 deg. C, while in the basal plane, the a dimension displays a slight linear contraction up to 750 deg. C with a contraction coefficient of -8.76 x 10 -7 K -1 , but above 750 deg. C a linear expansion is observed with a larger expansion coefficient of 1.52 x 10 -6 K -1

  15. 7 CFR 1000.14 - Other source milk.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 9 2010-01-01 2009-01-01 true Other source milk. 1000.14 Section 1000.14 Agriculture... and Orders; Milk), DEPARTMENT OF AGRICULTURE GENERAL PROVISIONS OF FEDERAL MILK MARKETING ORDERS Definitions § 1000.14 Other source milk. Other source milk means all skim milk and butterfat contained in or...

  16. The Wilson-Bappu effect of the MgII k line - dependence on stellar temperature, activity and metallicity

    DEFF Research Database (Denmark)

    Elgaroy, O.; Engvold, O.; Lund, Niels

    1999-01-01

    widths around the regression lines. The sample contains slowly rotating stars of different activity levels and is suitable for investigations of a possible relation between line width and stellar activity. A difference in behavior between dwarfs and giants (and supergiants) of spectral class K seems......The Wilson-Bappu effect is investigated using accurate absolute magnitudes of 65 stars obtained through early release of data from the Hipparcos satellite together with MgII k fine widths determined from high resolution spectra observed with the International Ultraviolet Explorer (IUE) observatory....... Stars of spectral classes F, G, K and M and luminosity classes I-V are represented in the sample. Wilson-Bappu relations for the Mg II k line for stars of different temperatures i.e. spectral classes are determined. The relation varies with spectral class and there is a significant scatter of the line...

  17. The volumetric properties of (1,2-propanediol carbonate+benzene, or toluene, or styrene) binary mixtures at temperatures from T=293.15 K to T=353.15 K

    International Nuclear Information System (INIS)

    Wang Haijun; Wu Yonghua; Huang Jihou

    2006-01-01

    The densities and excess molar volumes V m E for binary liquid mixtures of (1,2-propanediol carbonate+benzene, or toluene, or ethylbenzene, or styrene) have been measured as a function of compositions using a vibrating-tube densimeter in the temperature range of (293.15 to 353.15) K and at atmospheric pressure. The V m E results were correlated using the fourth-order Redlich-Kister equation. It was found that the V m E in these systems studied increases with rising temperature

  18. The design of high-temperature thermal conductivity measurements apparatus for thin sample size

    Directory of Open Access Journals (Sweden)

    Hadi Syamsul

    2017-01-01

    Full Text Available This study presents the designing, constructing and validating processes of thermal conductivity apparatus using steady-state heat-transfer techniques with the capability of testing a material at high temperatures. This design is an improvement from ASTM D5470 standard where meter-bars with the equal cross-sectional area were used to extrapolate surface temperature and measure heat transfer across a sample. There were two meter-bars in apparatus where each was placed three thermocouples. This Apparatus using a heater with a power of 1,000 watts, and cooling water to stable condition. The pressure applied was 3.4 MPa at the cross-sectional area of 113.09 mm2 meter-bar and thermal grease to minimized interfacial thermal contact resistance. To determine the performance, the validating process proceeded by comparing the results with thermal conductivity obtained by THB 500 made by LINSEIS. The tests showed the thermal conductivity of the stainless steel and bronze are 15.28 Wm-1K-1 and 38.01 Wm-1K-1 with a difference of test apparatus THB 500 are −2.55% and 2.49%. Furthermore, this apparatus has the capability to measure the thermal conductivity of the material to a temperature of 400°C where the results for the thermal conductivity of stainless steel is 19.21 Wm-1K-1 and the difference was 7.93%.

  19. 25 CFR 39.1000 - Purpose and scope.

    Science.gov (United States)

    2010-04-01

    ... 25 Indians 1 2010-04-01 2010-04-01 false Purpose and scope. 39.1000 Section 39.1000 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR EDUCATION THE INDIAN SCHOOL EQUALIZATION PROGRAM Administrative Cost Formula § 39.1000 Purpose and scope. The purpose of this subpart is to provide funds at the...

  20. 27 CFR 19.1000 - Reconsignment in transit.

    Science.gov (United States)

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Reconsignment in transit. 19.1000 Section 19.1000 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE..., Withdrawals and Transfers § 19.1000 Reconsignment in transit. When, prior to or on arrival at the premises of...

  1. The phase system Fe-Ir-S at 1100, 1000 and 800 degree C

    DEFF Research Database (Denmark)

    Makovicky, Emil; Karup-Møller, Sven

    1999-01-01

    Phase relations in the dry condensed Fe-Ir-S system were determined at 1100, 1000 and 800 degrees C. Orientational runs were performed at 500 degrees C. Between 1100 and 800 degrees C, the system comprises five sulphides and an uninterrupted field of gamma(Fe, Ir). Fe1-xS dissolves 5.8 at.% Ir...... at 1100 degrees C, 3.4 at.% Ir at 1000 degrees C and 1.0 at.% Ir at 800 degrees C. The solubility of Fe in Ir2S3, IrS2 and IrSsimilar to 3 increases with decreasing temperature, reaching 2.5 at.% in the latter two sulphides at 800 degrees C. Thiospinel 'FeIr2S4' is nonstoichiometric, from Fe22.3Ir19.8S58...

  2. Oxidation behavior of U-Si compounds in air from 25 to 1000 C

    Science.gov (United States)

    Sooby Wood, E.; White, J. T.; Nelson, A. T.

    2017-02-01

    The air oxidation behavior of U3Si2, USi, and U3Si5 is studied from room temperature to 1000 C. The onsets of breakaway oxidation for each compound are identified during synthetic air ramps to 1000 C using thermogravimetric analysis. Isothermal air oxidation tests are performed below and above the breakaway oxidation onset to discern the oxidation kinetic behavior of these candidate accident tolerant fuel forms. Uranium metal is tested in the same manner to provide a reference for the oxidation behavior. Thermogravimetric, x-ray diffraction, and scanning electron microscopy analysis are presented here along with a discussion of the oxidation behavior of these materials and the impact of the lack of oxidation resistance to their deployment as accident tolerant nuclear fuels.

  3. Thermogravimetric analysis of silicon carbide-silicon nitride polycarbosilazane precursor during pyrolysis from ambient to 1000 C

    Science.gov (United States)

    Ledbetter, F. E., III; Daniels, J. G.; Clemons, J. M.; Hundley, N. H.; Penn, B. G.

    1984-01-01

    Thermogravimetric analysis data are presented on the unmeltable polycarbosilazane precursor of silicon carbide-silicon nitride fibers, over the room temperature-1000 C range in a nitrogen atmosphere, in order to establish the weight loss at various temperatures during the precursor's pyrolysis to the fiber material. The fibers obtained by this method are excellent candidates for use in applications where the oxidation of carbon fibers (above 400 C) renders them unsuitable.

  4. 3D analysis of the reactivity insertion accident in VVER-1000

    Energy Technology Data Exchange (ETDEWEB)

    Abdullayev, A. M.; Zhukov, A. I.; Slyeptsov, S. M. [NSC Kharkov Inst. for Physics and Technology, 1, Akademicheskaya Str., Kharkov 61108 (Ukraine)

    2012-07-01

    Fuel parameters such as peak enthalpy and temperature during rod ejection accident are calculated. The calculations are performed by 3D neutron kinetics code NESTLE and 3D thermal-hydraulic code VIPRE-W. Both hot zero power and hot full power cases were studied for an equilibrium cycle with Westinghouse hex fuel in VVER-1000. It is shown that the use of 3D methodology can significantly increase safety margins for current criteria and met future criteria. (authors)

  5. Rate constant and mechanism of the reaction Cl + CFCl₂H → CFCl₂ + HCl over the temperature range 298-670 K in N₂ or N₂/O₂ diluent.

    Science.gov (United States)

    Kaiser, E W; Jawad, Khadija M

    2014-05-08

    The rate constant of the reaction Cl + CFCl2H (k1) has been measured relative to the established rate constant for the reaction Cl + CH4 (k2) at 760 Torr. The measurements were carried out in Pyrex reactors using a mixture of CFCl2H, CH4, and Cl2 in either N2 or N2/O2 diluent. Reactants and products were quantified by GC/FID analysis. Cl atoms were generated by irradiation of the mixture with 360 nm light to dissociate the Cl2 for temperatures up to ~550 K. At higher temperature, the Cl2 dissociated thermally, and no irradiation was used. Over the temperature range 298-670 K, k1 is consistently a factor of ~5 smaller than that of k2 with a nearly identical temperature dependence. The optimum non-Arrhenius rate constant is represented by the expression k1 = 1.14 × 10(-22) T(3.49) e(-241/T) cm(3) molecule(-1) s(-1) with an estimated uncertainty of ±15% including uncertainty in the reference reaction. CFCl3 formed from the reaction CFCl2 + Cl2 (k3) is the sole product in N2 diluent. In ~20% O2 at 298 K, the CFCl3 product is suppressed. The rate constant of reaction 3 was measured relative to that of reaction 4 [CFCl2 + O2 (k4)] giving the result k3/k4 = 0.0031 ± 0.0005 at 298 K. An earlier experiment by others observed C(O)FCl to be the major product of reaction channel 4 [formed via the sequence, CFCl2(O2) → CFCl2O → C(O)FCl + Cl]. Our current experiments verified that there is a Cl atom chain reaction in the presence of O2 as required by this mechanism.

  6. Mechano-chemical synthesis K2MF6 (M = Mn, Ni) by cation-exchange reaction at room temperature

    Science.gov (United States)

    Rawat, Pooja; Nagarajan, Rajamani

    2018-02-01

    In order to establish the power of mechanochemistry to produce industrially important phosphors, synthesis of K2MnF6 has been attempted by the successive grinding reactions of manganese (II) acetate with ammonium fluoride and potassium fluoride. The progress of reaction was followed by ex-situ characterization after periodic intervals of time. Cubic symmetry of K2MnF6 was evident from its powder X-ray diffraction pattern which was refined successfully in cubic space group (Fm-3m) with a = 8.4658 (20) Å. Stretching and bending vibration modes of MnF62- octahedral units appeared at 740 and 482 cm-1 in the fourier transformed infrared spectrum. Bands at 405 and 652 cm-1 appeared in the Raman spectrum and they were finger-print positions of cubic K2MnF6. Other than the ligand to metal charge transfer transition at 242 nm, transitions from 4A2g to 4T1g, 4T2g and 2T2g of Mn4+-ion appeared at 352, 429, 474 and 569 nm in the UV-visible diffuse reflectance spectrum of the sample. Red emission due to Mn4+ was observed in the photoluminescence spectrum with a decay time of 0.22 ms. Following the success in forming cubic K2MnF6, this approach has been extended to synthesize cubic K2NiF6 at room temperature. All these results confirmed the susceptibility of acetate salts of transition metals belonging to first-row of the periodic table to facile fluorination at room temperature aided by mechanical forces.

  7. Uncertainty Evaluation with Multi-Dimensional Model of LBLOCA in OPR1000 Plant

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jieun; Oh, Deog Yeon; Seul, Kwang-Won; Lee, Jin Ho [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of)

    2016-10-15

    KINS has used KINS-REM (KINS-Realistic Evaluation Methodology) which developed for Best- Estimate (BE) calculation and uncertainty quantification for regulatory audit. This methodology has been improved continuously by numerous studies, such as uncertainty parameters and uncertainty ranges. In this study, to evaluate the applicability of improved KINS-REM for OPR1000 plant, uncertainty evaluation with multi-dimensional model for confirming multi-dimensional phenomena was conducted with MARS-KS code. In this study, the uncertainty evaluation with multi- dimensional model of OPR1000 plant was conducted for confirming the applicability of improved KINS- REM The reactor vessel modeled using MULTID component of MARS-KS code, and total 29 uncertainty parameters were considered by 124 sampled calculations. Through 124 calculations using Mosaique program with MARS-KS code, peak cladding temperature was calculated and final PCT was determined by the 3rd order Wilks' formula. The uncertainty parameters which has strong influence were investigated by Pearson coefficient analysis. They were mostly related with plant operation and fuel material properties. Evaluation results through the 124 calculations and sensitivity analysis show that improved KINS-REM could be reasonably applicable for uncertainty evaluation with multi-dimensional model calculations of OPR1000 plants.

  8. A high-temperature high-pressure calorimeter for determining heats of solution up to 623 K.

    Science.gov (United States)

    Djamali, Essmaiil; Turner, Peter J; Murray, Richard C; Cobble, James W

    2010-07-01

    A high-temperature high-pressure isoperibol calorimeter for determining the heats of solution and reaction of very dilute substances in water (10(-4) m) at temperatures up to 623 K is described. The energies of vaporization of water at steam saturation pressure were measured as a function of temperature and the results agree with the corresponding values from steam tables to better than 0.08+/-0.18%. The novelties of the present instrument relative to flow type heat capacity calorimeters are that measurements can be made at orders of magnitude lower concentrations and that measurement of heat of reaction involving solids or gases or in the presence of high concentrations of supporting electrolytes, acids, and bases is possible. Furthermore, the advantage of using enthalpy data over heat capacity data for calculations of the standard state Gibbs free energies of electrolytes is that the experimental heat data of this research need only be integrated once to derive higher temperature free energy data from lower temperatures. The derived heat capacities can be used mathematically to obtain free energies by double integration. However, the resulting errors are much smaller than if experimental aqueous heat capacities were used for the integrations.

  9. TEMPERATURE PREDICTION IN 3013 CONTAINERS IN K AREA MATERIAL STORAGE (KAMS) FACILITY USING REGRESSION METHODS

    International Nuclear Information System (INIS)

    Gupta, N

    2008-01-01

    3013 containers are designed in accordance with the DOE-STD-3013-2004. These containers are qualified to store plutonium (Pu) bearing materials such as PuO2 for 50 years. DOT shipping packages such as the 9975 are used to store the 3013 containers in the K-Area Material Storage (KAMS) facility at Savannah River Site (SRS). DOE-STD-3013-2004 requires that a comprehensive surveillance program be set up to ensure that the 3013 container design parameters are not violated during the long term storage. To ensure structural integrity of the 3013 containers, thermal analyses using finite element models were performed to predict the contents and component temperatures for different but well defined parameters such as storage ambient temperature, PuO 2 density, fill heights, weights, and thermal loading. Interpolation is normally used to calculate temperatures if the actual parameter values are different from the analyzed values. A statistical analysis technique using regression methods is proposed to develop simple polynomial relations to predict temperatures for the actual parameter values found in the containers. The analysis shows that regression analysis is a powerful tool to develop simple relations to assess component temperatures

  10. Temperature dependence of the dynamics of zone boundary phonons in ZnO:Li

    Science.gov (United States)

    Yadav, Harish Kumar; Sreenivas, K.; Gupta, Vinay; Katiyar, R. S.

    2008-12-01

    Investigations of zone boundary phonons in ZnO:Li system (Li concentration: 10%) and their dynamics with temperature are reported. Additional modes at 127, 157, and 194 cm-1 are observed and assigned to zone boundary phonons at critical point M in the Brillouin zone [J. M. Calleja and M. Cardona, Phys. Rev. B 16, 3753 (1977)] due to breakdown of crystal translational symmetry with Li incorporation in ZnO. Anharmonicity in peak frequency and linewidth of the zone boundary phonons in a temperature range from 100 to 1000 K is also analyzed taking into account the decay of zone boundary phonons into three- and four-phonon modes (cubic and quadratic anharmonicities). The anharmonic behavior of peak frequency is found to be feebly dependent on three-phonon decay process but thermal expansion of lattice together with four-phonon decay process appropriately defines the temperature dependence. Linewidths, however, follow the simple four-phonon decay mechanism. E2(low) mode, on the other hand, shows a linear temperature dependency and therefore follows a three-phonon decay channel. The calculated values of phonon lifetimes at 100 K for the 127, 157, 194 cm-1, and E2(low) modes are 8.23, 6.54, 5.32, and 11.39 ps. Decay of the zone boundary phonon modes compared to E2(low) mode reveals that dopant induced disorder has a strong temperature dependency.

  11. Evaluation of WWER-1000 vessel materials fracture toughness

    International Nuclear Information System (INIS)

    Grinik, Eh.U.; Revka, V.N.; Chirko, L.I.; Chajkovskij, Yu.V.

    2007-01-01

    The lifetime of WWER-1000-type reactor vessels is finally conditioned by the fracture toughness (crack growth resistance) of RPV materials. Up to now in line with the regulations the fracture toughness is characterized by the critical temperature of brittleness determined by the results of the Charpy specimen impact testing. Such approach is typical for all countries operating the water pressure reactors. However, regulatory approach is known from the western specialists not always to characterize adequately the crack growth resistance of the vessel materials and in some cases to underestimate their characteristics in the reference state that leads to unreasonably high conservatism. Excessive conservatism may lead to the invalid restrictions in the operating modes and the service life of the reactor vessel. Therefore there appeared the necessity to apply another approaches based on the state-of-the-art experimental methods of the fracture mechanics and allowing evaluating the fracture toughness parameters sufficiently. The paper presents the results of the comparison of the regulatory approach and the Master curve approach from the point of view of the adequate determination of the vessel material crack growth resistance parameters. Analysis of the experimental data of the surveillance specimens illustrated the potential possibility of applying the new statistical method for the WWER-1000- type reactor vessel lifetime extension

  12. OECD/DOE/CEA VVER-1000 Coolant Transient Benchmark. Summary Record of the First Workshop (V1000-CT1)

    International Nuclear Information System (INIS)

    2003-01-01

    The first workshop for the VVER-1000 Coolant Transient Benchmark TT Benchmark was hosted by the Commissariat a l'Energie Atomique, Centre d'Etudes de Saclay, France. The V1000CT benchmark defines standard problems for validation of coupled three-dimensional (3-D) neutron-kinetics/system thermal-hydraulics codes for application to Soviet-designed VVER-1000 reactors using actual plant data without any scaling. The overall objective is to access computer codes used in the safety analysis of VVER power plants, specifically for their use in reactivity transient simulations in a VVER-1000. The V1000CT benchmark consists of two phases: V1000CT-1 - simulation of the switching on of one main coolant pump (MCP) while the other three MCP are in operation, and V1000CT- 2 - calculation of coolant mixing tests and Main Steam Line Break (MSLB) scenario. Further background information on this benchmark can be found at the OECD/NEA benchmark web site . The purpose of the first workshop was to review the benchmark activities after the Starter Meeting held last year in Dresden, Germany: to discuss the participants' feedback and modifications introduced in the Benchmark Specifications on Phase 1; to present and to discuss modelling issues and preliminary results from the three exercises of Phase 1; to discuss the modelling issues of Exercise 1 of Phase 2; and to define work plan and schedule in order to complete the two phases

  13. X-ray and neutron powder investigations of pure and yttrium doped CeO2 at temperatures up to 1600 K

    International Nuclear Information System (INIS)

    Berber, K.; Martin, U.; Mursic, Z.; Schneider, J.; Boysen, H.; Frey, F.

    1991-01-01

    Ceria, CeO 2 powders and sintermaterials with different amounts of yttria, Y 2 O 3 , (0-10 mole %) were investigated up to 1600 K by X-ray and neutron powder diffraction. In the sample with 3 mole % yttria the onset of a solid-state reaction or a kind of phase change at 900 K is indicated by a change of the lattice expansion coefficient and by an increase of the slope of the B iso (T) curve. Microstrains are present in the sintered material above 900 K. Anharmonic contributions to the temperature factor of the oxygens become significant at higher temperatures. We deduce from a non-zero part B T ≠0 some static disorder within the O-sublattice. Pdf-maps of the oxygens show clearly deformations of the 'normal' isotropic behaviour, but exceptional smearing out or even closed pathways are not observed. Thus, the superior anionic conductivity of this material is not reflected by the features of the averaged structure. It is most likely due to a disordered 'interface-structure' between ordered domains. A temperature dependent 'structured' background scattering supports this conclusion. (author) 6 figs., 9 refs

  14. Testing the potential of an elevated temperature IRSL signal from K-feldspar

    DEFF Research Database (Denmark)

    Buylaert, Jan-Pieter; Murray, A.S.; Thomsen, Kristina Jørkov

    2009-01-01

    on laboratory tests (recycling ratio, recuperation, dose recovery) we show that our SAR protocol is suitable for these samples. The observed post-IR IR fading rates (mean g2days = 1.62 ± 0.06%/decade, n = 24; assuming logarithmic fading) are significantly lower than those measured at 50 °C (mean g2days = 3...... the conventional IRSL signal stimulated at 50 °C and detected in the blue–violet region of the spectrum. One of these was the post-IR IR signal in which first an IR bleach is carried out at a low temperature (e.g. 100 s at 50 °C) and a remaining IRSL signal is measured at an elevated temperature (100 s at 225 °C......; detection in the blue–violet region). It is the latter signal that is of interest in this paper. We test such a post-IR IR dating protocol on K-feldspar extracts from a variety of locations and depositional environments and compare the results with those from the conventional IR at 50 °C protocol. Based...

  15. Changes in the flexural strength of engineering ceramics after high temperature sodium corrosion test. Influence after sodium exposure for 1000 hours

    International Nuclear Information System (INIS)

    Hayashi, Kazunori; Tachi, Yoshiaki; Kano, Shigeki; Hirakawa, Yasushi; Komine, Ryuji; Yoshida, Eiichi

    1998-02-01

    Engineering ceramics have excellent properties such as high strength, high hardness and high heat resistance compared with metallic materials. To apply the ceramic in fast reactor environment, it is necessary to evaluate the sodium compatibility and the influence of sodium on the mechanical properties of ceramics. In this study, the influence of high temperature sodium on the mechanical properties of sintered ceramics of conventional and high purity Al 2 O 3 , SiC, SiAlON, AlN and unidirectional solidified ceramics of Al 2 O 3 /YAG eutectic composite were investigated by means of flexure tests. Test specimens were exposed in liquid sodium at 823K and 923K for 3.6Ms. There were no changes in the flexural strength of the conventional and high purity Al 2 O 3 , AlN and Al 2 O 3 /YAG eutectic composite after the sodium exposure at 823K. On the contrary, the decrease in the flexural strength was observed in SiC and SiAlON. After the sodium exposure at 923K, there were also no changes in the flexural strength of AlN and Al 2 O 3 /YAG eutectic composite. In the conventional and high purity Al 2 O 3 and SiC, the flexural strength decreased and signs of grain boundary corrosion were detected by surface observation. The flexural strength of SiAlON after the sodium exposure at 923K increased instead of severe corrosion. In the specimens those showed no changes in the flexural strength, further exposure in sodium is needed to verify whether the mechanical properties degrade or not. For SiAlON, it is necessary to clarify the reason for the increased strength after the sodium exposure at 923K. (author)

  16. Study of elastic and thermodynamic properties of uranium dioxide under high temperature and pressure with density functional theory

    International Nuclear Information System (INIS)

    Zhou Mu; Wang Feng; Zheng Zhou; Liu Xiankun; Jiang Tao

    2013-01-01

    The elastic and thermodynamic properties of UO 2 under extreme physical condition are studied by using the density functional theory and quasi-harmonic Debye model. Results show that UO 2 is still stable ionic crystal under high temperatures, and pressures. Tetragonal shear constant is steady under high pressures and temperatures, while elastic constant C 44 is stable under high temperatures, but rises with pressure sharply. Bulk modulus, shear modulus and Young's modulus increase with pressure rapidly, but temperature would not cause evident debasement of the moduli, all of which indicate that UO 2 has excellent mechanical properties. Heat capacity of different pressures increases with temperature and is close to the Dulong-Petit limit near 1000 K. Debye temperature decreases with temperature, and increases with pressure. Under low pressure, thermal expansion coefficient raises with temperature rapidly, and then gets slow at higher pressure and temperature. Besides, the thermal expansion coefficient of UO 2 is much lower than that of other nuclear materials. (authors)

  17. Test results of a 20 kA high temperature superconductor current lead using REBCO tapes

    Science.gov (United States)

    Heller, R.; Fietz, W. H.; Gröner, F.; Heiduk, M.; Hollik, M.; Lange, C.; Lietzow, R.

    2018-05-01

    The Karlsruhe Institute of Technology has developed a 20 kA high temperature superconductor (HTS) current lead (CL) using the second generation material REBCO, as industry worldwide concentrate on the production of this material. The aim was to demonstrate the possibility of replacing the Bi-2223/AgAu tapes by REBCO tapes, while for easy comparison of results, all other components are copies of the 20 kA HTS CL manufactured for the satellite tokamak JT-60SA. After the manufacture of all CL components including the newly developed REBCO module, the assembly of the CL has been executed at KIT and an experiment has been carried out in the CuLTKa test facility where the REBCO CL was installed and connected to a JT-60SA CL via a superconducting bus bar. The experiment covers steady state operation up to 20 kA, pulsed operation, measurement of the heat load at 4.5 K end, loss-of-flow-accident simulations, and quench performance studies. Here the results of these tests are reported and directly compared to those of the JT-60SA CL.

  18. A model for the operation of helium-filled proportional counter at low temperatures near 4.2 K

    International Nuclear Information System (INIS)

    Masaoka, Sei; Katano, Rintaro; Kishimoto, Shunji; Isozumi, Yasuhito

    2000-01-01

    In order to understand the operation of helium-filled proportional counter (HFPC) from the standpoint of fundamental atomic and molecular processes, we have surveyed previous works on collision processes in discharged helium gas. By analyzing gas gain curve, after-pulses and discharge current experimentally observed at 4.2 K, the electron avalanche and the secondary electron emission from cathode have been related to the collision processes in helium. A simplified model for the HFPC operation at low temperatures near 4.2 K has been constructed with the related processes

  19. Optimizing a gap conductance model applicable to VVER-1000 thermal–hydraulic model

    International Nuclear Information System (INIS)

    Rahgoshay, M.; Hashemi-Tilehnoee, M.

    2012-01-01

    Highlights: ► Two known conductance models for application in VVER-1000 thermal–hydraulic code are examined. ► An optimized gap conductance model is developed which can predict the gap conductance in good agreement with FSAR data. ► The licensed thermal–hydraulic code is coupled with the gap conductance model predictor externally. -- Abstract: The modeling of gap conductance for application in VVER-1000 thermal–hydraulic codes is addressed. Two known models, namely CALZA-BINI and RELAP5 gap conductance models, are examined. By externally linking of gap conductance models and COBRA-EN thermal hydraulic code, the acceptable range of each model is specified. The result of each gap conductance model versus linear heat rate has been compared with FSAR data. A linear heat rate of about 9 kW/m is the boundary for optimization process. Since each gap conductance model has its advantages and limitation, the optimized gap conductance model can predict the gap conductance better than each of the two other models individually.

  20. Phase equilibrium measurements and thermodynamic modeling of aqueous solutions of polyamines CO_2 absorbents: 3-aminopropylmethylamine, 3-aminopropyldimethylamine and N,N-diethyl 1,3-propanediamine at temperatures from 273 K to 363 K

    International Nuclear Information System (INIS)

    Bouzina, Zahida; Mokbel, Ilham; Negadi, Amina; Jose, Jacques; Negadi, Latifa

    2016-01-01

    Highlights: • Experimental vapor pressures of pure MAPA, DMAPA, DEAPA and their aqueous solutions are reported. • The investigated temperatures are 273 K through 363 K. • The MAPA binary system exhibits negative deviations in G"E values. • The DMAPA and DEAPA systems exhibit negative, sinusoidal and positive deviations in G"E values. • The 3rd order Redlich–Kister, and NRTL or UNIQUAC models have been used to correlate the (P-x-y) data. - Abstract: The vapor pressures of the pure components 3-aminopropylmethylamine (MAPA), 3-aminopropyldimethylamine (DMAPA) and N,N-diethyl 1,3-propanediamine (DEAPA) along with the binary mixtures (MAPA + water), (DMAPA + water) and (DEAPA + water) were measured by means of a static apparatus at temperatures between (273 and 363) K. The data were correlated with the Antoine equation. From these data, excess Gibbs functions (G"E) were calculated for several constant temperatures, and fitted to a three parameters Redlich–Kister equation using the Barker’s method. Additionally, the NRTL and UNIQUAC models have been used for the correlation of the total pressure.

  1. Effects of vacuum-ultraviolet irradiation on copper penetration into low-k dielectrics under bias-temperature stress

    Energy Technology Data Exchange (ETDEWEB)

    Guo, X.; Zheng, H.; Xue, P.; Shohet, J. L. [Plasma Processing and Technology Laboratory and Department of Electrical and Computer Engineering, University of Wisconsin-Madison, Madison, Wisconsin 53706 (United States); King, S. W. [Logic Technology Development, Intel Corporation, Hillsboro, Oregon 97124 (United States); Nishi, Y. [Department of Electrical Engineering, Stanford University, Stanford, California 94305 (United States)

    2015-01-05

    The effects of vacuum-ultraviolet (VUV) irradiation on copper penetration into non-porous low-k dielectrics under bias-temperature stress (BTS) were investigated. By employing x-ray photoelectron spectroscopy depth-profile measurements on both as-deposited and VUV-irradiated SiCOH/Cu stacks, it was found that under the same BTS conditions, the diffusion depth of Cu into the VUV-irradiated SiCOH is higher than that of as-deposited SiCOH. On the other hand, under the same temperature-annealing stress (TS) without electric bias, the Cu distribution profiles in the VUV-irradiated SiCOH were same with that for the as-deposited SiCOH. The experiments suggest that in as-deposited SiCOH, the diffused Cu exists primarily in the atomic state, while in VUV-irradiated SiCOH, the diffused Cu is oxidized by the hydroxyl ions (OH{sup −}) generated from VUV irradiation and exists in the ionic state. The mechanisms for metal diffusion and ion injection in VUV irradiated low-k dielectrics are discussed.

  2. Reactor coolant system hydrostatic test and risk analysis for the first AP1000 unit

    International Nuclear Information System (INIS)

    Cao Hongjun; Yan Xiuping

    2013-01-01

    The cold hydrostatic test scheme of the primary coolant circuit, of the first AP1000 unit was described. Based on the up-stream design documents, standard specifications and design technical requirements, the select principle of test boundary was identified. The design requirements for water quality, pressure, temperature and temporary hydro-test pump were proposed. A reasonable argument for heating and pressurization rate, and cooling and depressurization rate was proposed. The possible problems and risks during the hydrostatic test were analyzed. This test scheme can provide guidance for the revisions and implementations of the follow-up test procedures. It is a good reference for hydrostatic tests of AP1000 units in the future in China. (authors)

  3. Role of N defects in paramagnetic CrN at finite temperatures from first principles

    Science.gov (United States)

    Mozafari, E.; Alling, B.; Steneteg, P.; Abrikosov, Igor A.

    2015-03-01

    Simulations of defects in paramagnetic materials at high temperature constitute a formidable challenge to solid-state theory due to the interaction of magnetic disorder, vibrations, and structural relaxations. CrN is a material where these effects are particularly large due to a strong magnetolattice coupling and a tendency for deviations from the nominal 1:1 stoichiometry. In this work, we present a first-principles study of nitrogen vacancies and nitrogen interstitials in CrN at elevated temperature. We report on formation energetics, the geometry of interstitial nitrogen dimers, and the impact on the electronic structure caused by the defects. We find a vacancy formation energy of 2.28 eV with a small effect of temperature, i.e., a formation energy for N interstitial in the form of a -oriented split bond of 3.77 eV with an increase to 3.97 at 1000 K. Vacancies are found to add three electrons, while split-bond interstitial adds one electron to the conduction band. The band gap of defect-free CrN is smeared out due to vibrations, although it is difficult to draw a conclusion about the exact temperature at which the band gap closes from our calculations. However, it is clear that at 900 K there is a nonzero density of electronic states at the Fermi level. At 300 K, our results indicate a border case where the band gap is about to close.

  4. Modelling accidental releases of dangerous gases into the lower troposphere from mobile sources

    Czech Academy of Sciences Publication Activity Database

    Bernatík, A.; Zimmermann, W.; Pitt, M.; Střižík, M.; Nevrlý, J.; Zelinger, Zdeněk

    2008-01-01

    Roč. 86, B3 (2008), s. 198-207 ISSN 0957-5820 R&D Projects: GA MŠk OC 111 Grant - others:GA MŠk OC 186 Institutional research plan: CEZ:AV0Z40400503 Keywords : major accidents * transportation of dangerous * substances modelling of release and dispersion Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 0.400, year: 2008

  5. Detection of cytoskeletal proteins in small cell lung carcinoma

    Czech Academy of Sciences Publication Activity Database

    Hložánková, M.; Lukáš, Z.; Viklický, Vladimír

    1999-01-01

    Roč. 18, - (1999), s. 47-49 ISSN 0231-5882 Grant - others:MŠk1(CZ) OE10a/EU1450 Keywords : cytoskeletal proteins * small cell lung carcinoma Subject RIV: EI - Biotechnology ; Bionics Impact factor: 0.400, year: 1999

  6. Thermodynamic and transport properties of (1-Butanol + 1,4-Butanediol) at temperatures from (298.15 to 318.15) K

    International Nuclear Information System (INIS)

    Zorebski, Edward; Geppert-Rybczynska, Monika

    2010-01-01

    Densities and kinematic viscosities have been measured for (1-butanol + 1,4-butanediol) over the temperature range from (298.15 to 318.15) K. The speeds of sound within the temperature range from (293.15 to 318.15) K have been measured as well. Using these results and literature values of isobaric heat capacities, the molar volumes, isentropic and isothermal compressibility coefficients, molar isentropic and isothermal compressibilities, isochoric heat capacities as well as internal pressures were calculated. Also the corresponding excess and deviation values (excess molar volumes, excess isentropic and isothermal compressibility coefficients, excess molar isentropic and isothermal compressibilities, different defined deviation speed of sound and dynamic viscosity deviations) were calculated. The excess values are negative over the whole concentration and temperature range. The excess and deviation values are expressed by Redlich-Kister polynomials and discussed in terms of the variations of the structure of the system caused by the participation of the two different alcohol molecules in the dynamic intermolecular association process through hydrogen bonding at various temperatures. The predictive abilities of Grunberg-Nissan and McAllister equations for viscosities of mixtures have also been examined.

  7. Research of resonant losses of ultrasonic sound in the deformed single crystals in temperature range 77...300 K

    International Nuclear Information System (INIS)

    Petchenko, A.M.; Petchenko, G.A.

    2007-01-01

    The damped dislocation resonance in preliminary deformed up to 1 % single crystals KBr was investigated. The measurements of a frequency dependence of a dislocation damping decrement of ultrasonic sound were conducted in range of frequencies 7,5...217,5 MHz and temperature range 77...300 K. From the analysis of frequency spectrums the temperature course of a coefficient of phonon viscosity B was determined, which is agreed both with the theory and experimental literary data. The influencing temperature changes of length of a dislocation segment on parameters of a resonant maximum and dynamic drag of dislocations by phonons was revealed and analyzed

  8. Effects of temperature and pressure on thermodynamic properties of Cd0.50 Zn0.50 Se alloy

    Science.gov (United States)

    Aarifeen, Najm ul; Afaq, A.

    2017-09-01

    Thermodynamic properties of \\text{C}{{\\text{d}}0.50} \\text{Z}{{\\text{n}}0.50} Se alloy are studied using quasi harmonic model for pressure range 0-10 GPa and temperature range 0-1000K. The structural optimization is obtained by self consistent field calculations and full-potential linear muffin-tin orbital method with GGA+U as an exchange correlation functional where U=2.3427 eV is the hubbard potential. The effects of temperature and pressure on the bulk modulus, Helmholtz free energy, internal energy, entropy, Debye temperature, Grüneisen parameter, thermal expansion coefficient and heat capacities of the material are observed and discussed. The bulk modulus, Helmholtz free energy and Debye temperature are found to decrease with increasing temperature while there is an increasing behavior when the pressure rises. Whereas internal energy has increasing trend with rises in temperature and it almost remains insensitive to pressure. The entropy of the system increases (decreases) with a rise of pressure (temperature).

  9. Phase stability and elastic properties of Tan+1AlCn (n = 1-3) at high pressure and elevated temperature

    International Nuclear Information System (INIS)

    Music, Denis; Emmerlich, Jens; Schneider, Jochen M

    2007-01-01

    We have studied the electronic structure of Ta n+1 AlC n (space group P6 3 /mmc,n = 1-3) under uniform compression from 0 to 60 GPa and at temperatures from 0 to 1500 K using ab initio calculations. These phases can be characterized by alternating layers of high and low electron density and are referred to as nanolaminates. At 0 K we observe similar compressibilities in both the a and c directions for all phases investigated. This is unusual for nanolaminates. Based on the density of states analysis, we propose that these similar compressibilities may be caused by an increase in Ta-Al and Ta-Ta bonding strength as well as a stronger long-range interaction between TaC-TaC layers. No evidence of a phase transition is observed as the pressure is increased to 60 GPa. However, as the temperature is increased to approximately 1000 K without applying pressure, a first-order phase transition occurs in Ta 3 AlC 2 . These results are relevant for applications of Ta n+1 AlC n at elevated temperature and pressure

  10. Effect of nanostructure on thermoelectric properties of La0.7Sr0.3MnO3 in 300–600 K temperature range

    Science.gov (United States)

    Singh, Saurabh; Srivastav, Simant Kumar; Patel, Ashutosh; Chatterjee, Ratnamala; Pandey, Sudhir K.

    2018-05-01

    In oxide materials, nanostructuring effect has been found a very promising approach for the enhancement of figure-of-merit, ZT. In the present work, we have synthesized La0.7Sr0.3MnO3 (LSMO) compound using sol-gel method and samples of crystallite size of ∼20, ∼41, and ∼49 nm were obtained by giving different heat treatment. Seebeck coefficient (α), electrical resistivity (ρ), and thermal conductivity (κ) measurements were carried out in 300–600 K temperature range. The systematic change in the values of α from ∼‑19 μV/K to ∼‑24 μV/K and drastic reduction in the values of κ from ∼0.88 W/mK to ∼0.23 W/mK are observed as crystallite size is reduced from 49 nm to 20 nm at ∼600 K. Also, fall in the values of ρ in the paramagnetic (PM) insulator phase (400–600 K) are effectively responsible for the increasing trend in the values of ZT at high temperature. For the crystallite size of 41 nm, the value of ZT at 600 K was found to be ∼0.017.

  11. Xe/Kr Selectivity Measurements using AgZ-PAN at Various Temperatures

    International Nuclear Information System (INIS)

    Garn, Troy Gerry; Greenhalgh, Mitchell Randy; Watson, Tony Leroy

    2015-01-01

    In preparation for planned FY-15 Xe/Kr multi-column testing, a series of experiments were performed to determine the selectivity of Xe over Kr using the silver converted mordenite-polyacrylonitrile (AgZ-PAN) sorbent. Results from these experiments will be used for parameter selection guidelines to define test conditions for Kr gas capture purity evaluations later this year. The currently configured experimental test bed was modified by installing a new cooling apparatus to permit future multi-column testing with independent column temperature control. The modified test bed will allow for multi-column testing to facilitate a Xe separation followed by a Kr separation using engineered form sorbents. Selectivity experiments were run at temperatures of 295, 250 and 220 K. Two feed gas compositions of 1000 ppmv Xe, 150 ppmv Kr in either a He or an air balance were used. AgZ-PAN sorbent selectivity was calculated using Xe and Kr capacity determinations. AgZ-PAN sorbent selectivities for Xe over Kr of 72 were calculated at room temperature (295 K) using the feed gas with a He balance and 34 using the feed gas with an air balance. As the test temperatures were decreased the selectivity of Xe over Kr also decreased due to an increase in both Xe and Kr capacities. At 220 K, the sorbent selectivities for Xe over Kr were 22 using the feed gas with a He balance and 28 using the feed gas with an air balance. The selectivity results indicate that AgZ-PAN used in the first column of a multi-column configuration will provide adequate partitioning of Xe from Kr in the tested temperature range to produce a more pure Kr end product for collection.

  12. Phase transition temperatures of 405-725 K in superfluid ultra-dense hydrogen clusters on metal surfaces

    Energy Technology Data Exchange (ETDEWEB)

    Holmlid, Leif, E-mail: holmlid@chem.gu.se [Atmospheric Science, Department of Chemistry, University of Gothenburg, SE-412 96 Göteborg (Sweden); Kotzias, Bernhard [Airbus DS, Department Mechanical Engineering, D28199 Bremen (Germany)

    2016-04-15

    Ultra-dense hydrogen H(0) with its typical H-H bond distance of 2.3 pm is superfluid at room temperature as expected for quantum fluids. It also shows a Meissner effect at room temperature, which indicates that a transition point to a non-superfluid state should exist above room temperature. This transition point is given by a disappearance of the superfluid long-chain clusters H{sub 2N}(0). This transition point is now measured for several metal carrier surfaces at 405 - 725 K, using both ultra-dense protium p(0) and deuterium D(0). Clusters of ordinary Rydberg matter H(l) as well as small symmetric clusters H{sub 4}(0) and H{sub 3}(0) (which do not give a superfluid or superconductive phase) all still exist on the surface at high temperature. This shows directly that desorption or diffusion processes do not remove the long superfluid H{sub 2N}(0) clusters. The two ultra-dense forms p(0) and D(0) have different transition temperatures under otherwise identical conditions. The transition point for p(0) is higher in temperature, which is unexpected.

  13. Experimental determination of the Koo fuel temperature coefficient for an HTGR lattice

    Energy Technology Data Exchange (ETDEWEB)

    Agostini, P.; Benedetti, F.; Brighenti, G.; Chiodi, P. L.; Dell' Oro, P.; Giuliani, C.; Tassan, S.

    1974-10-15

    This paper describes temperature-dependent k-infinity measurements conducted using an assembly of loose HTGR coated particles in the BR-2 reactor by means of null reactivity oscillating method comparing the effect of poisoned and unpoisoned lattices like tests performed in the Physical Constants Test Reactor (PCTR) at Hanford. The RB-2 reactor was the property of the Italian firm AGIP NUCLEARE and operated at the Montecuccolino Center in Bologna.

  14. CCT-K2.1: NRC/VNIIFTRI bilateral comparison of capsule-type standard platinum resistance thermometers from 13.8 K to 273.16 K

    Energy Technology Data Exchange (ETDEWEB)

    Hill, K.D.; Steele, A.G. [National Research Council of Canada, Institute for National Measurement Standards, Ottawa, ON (Canada); Dedikov, Y.A.; Shkraba, V.T. [Institute for Physical-Technical and Radiotechnical Measurements (VNIIFTRI), Moscow (Russian Federation)

    2005-04-01

    The Consultative Committee for Thermometry Key Comparison 2 (CCT-K2) results were published two years ago (2002 Metrologia 39 551-71). NRC served as the pilot laboratory for CCT-K2 and remains able to provide a scale and measurement system suitable for performing bilateral comparisons linked to the original key comparison results. In March 2003, measurements of two VNIIFTRI 100 {omega} capsule-style platinum resistance thermometers (CSPRTs), S/N 356 and 476, were undertaken to relate their local calibration to the results from the CCT-K2 exercise. The NRC Leeds and Northrup (L and N) CSPRT S/N 1872174 provides the link to the CCT-K2 results. The three CSPRTs were compared at the eight defining cryogenic temperatures of the International Temperature Scale of 1990 (ITS-90) in the range from 13.8033 K to 273.16 K. The reader is referred to the full text of the CCT-K2 report for a detailed explanation of the methodology employed for the comparison. Only the details unique to the measurements reported here will be addressed in this article. The NRC/VNIIFTRI bilateral comparison of capsule-style platinum resistance thermometers over the range 13.8 K to 273.16 K has revealed calibrations at VNIIFTRI to be in agreement with the KCRV of CCT-K2 within the expanded uncertainty for all temperatures of the comparison with the exception of the triple point of hydrogen at 13.8033 K. One of the two CSPRTs supplied by VNIIFTRI was found to be discrepant as revealed by differences at the triple point of water and at the lowest temperatures of the comparison, and was therefore excluded from further analysis. The linkage to the CCT-K2 data supports the evaluation of the VNIIFTRI CMCs in Appendix C of the KCDB. (authors)

  15. Infrared normal spectral emissivity of Ti-6Al-4V alloy in the 500-1150 K temperature range

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez-Fernandez, L. [Departamento de Fisica de la Materia Condensada, Facultad de Ciencia y Tecnologia, Universidad del Pais Vasco, Barrio Sarriena s/n, 48940 Leioa, Bizkaia (Spain); Industria de Turbo Propulsores, S.A., Planta de Zamudio, Edificio 300, 48170 Zamudio, Bizkaia (Spain); Risueno, E. [CIC Energigune, Parque Tecnologico, Albert Einstein 48, 01510 Minano, Alava, Spain. (Spain); Perez-Saez, R.B., E-mail: raul.perez@ehu.es [Departamento de Fisica de la Materia Condensada, Facultad de Ciencia y Tecnologia, Universidad del Pais Vasco, Barrio Sarriena s/n, 48940 Leioa, Bizkaia (Spain); Instituto de Sintesis y Estudio de Materiales, Universidad del Pais Vasco, Apdo. 644,48080 Bilbao, Spain. (Spain); Tello, M.J. [Departamento de Fisica de la Materia Condensada, Facultad de Ciencia y Tecnologia, Universidad del Pais Vasco, Barrio Sarriena s/n, 48940 Leioa, Bizkaia (Spain); Instituto de Sintesis y Estudio de Materiales, Universidad del Pais Vasco, Apdo. 644,48080 Bilbao, Spain. (Spain)

    2012-11-15

    Highlights: Black-Right-Pointing-Pointer First heating cycle acts as a annealing, relieving the surface stresses. Black-Right-Pointing-Pointer Stress relieving occurs mainly above 900 K. Black-Right-Pointing-Pointer Emissivity decreases between 0.35 and 0.10 in the 2.5-22 {mu}m spectral range. Black-Right-Pointing-Pointer Emissivity increases linearly with temperature, with the same slope for {lambda} > 10 {mu}m. Black-Right-Pointing-Pointer Good agreement between resistivity and emissivity by means of Hagen-Rubens relation. - Abstract: Thermal radiative emissivity is related to the optical and electrical properties of materials, and it is a key parameter required in a large number of industrial applications. In the case of Ti-6Al-4V, spectral emissivity experimental data are not available for the range of temperatures between 400 and 1200 K, where almost all industrial applications take place. The experimental results in this paper show that the normal spectral emissivity decreases with wavelength from a value of about 0.35 at 2.5 {mu}m to about 0.10 at 22 {mu}m. At the same time, the spectral emissivity shows a slight linear increase with temperature between 500 and 1150 K, with approximately the same slope for all wavelengths. Additionally, the influence of the samples thermal history on the emissivity is studied. A strong decrease in the emissivity values appears due to the effect of surface stress relaxation processes. This means that the radiative properties of this alloy strongly depend on the surface stress state. A thermal treatment to relieve the surface stress should be carried out to achieve a steady state of the radiative properties. In addition, a good qualitative agreement is found between the temperature dependence of the electrical resistivity obtained using conventional measurements and the one obtained from the emissivity experimental results by using the Hagen-Rubens equation.

  16. Reaction CH3 + OH studied over the 294-714 K temperature and 1-100 bar pressure ranges.

    Science.gov (United States)

    Sangwan, Manuvesh; Chesnokov, Evgeni N; Krasnoperov, Lev N

    2012-08-30

    Reaction of methyl radicals with hydroxyl radicals, CH(3) + OH → products (1) was studied using pulsed laser photolysis coupled to transient UV-vis absorption spectroscopy over the 294-714 K temperature and 1-100 bar pressure ranges (bath gas He). Methyl radicals were produced by photolysis of acetone at 193.3 nm. Hydroxyl radicals were generated in reaction of electronically excited oxygen atoms O((1)D), produced in the photolysis of N(2)O at 193.3 nm, with H(2)O. Temporal profiles of CH(3) were recorded via absorption at 216.4 nm using xenon arc lamp and a spectrograph; OH radicals were monitored via transient absorption of light from a dc discharge H(2)O/Ar low pressure resonance lamp at ca. 308 nm. The absolute intensity of the photolysis light inside the reactor was determined by an accurate in situ actinometry based on the ozone formation in the presence of molecular oxygen. The results of this study indicate that the rate constant of reaction 1 is pressure independent within the studied pressure and temperature ranges and has slight negative temperature dependence, k(1) = (1.20 ± 0.20) × 10(-10)(T/300)(-0.49) cm(3) molecule(-1) s(-1).

  17. Use of TRIGA-pulsed irradiations for high-temperature Doppler measurements

    Energy Technology Data Exchange (ETDEWEB)

    Foell, W K; Cashwell, R J; Bhattacharyya, S K [Argonne National Laboratory, Argonne, IL (United States); Russell, G J [Los Alamos Scientific Laboratory, University of California, Los Alamos, NM (United States)

    1974-07-01

    experimentally measured values. Explicit correlations for the Doppler Ratio were derived from the results of the present work. Since the Doppler Ratios were measured over a range of temperatures in the PAD experiment, effective static temperatures were defined for use in the correlations. The PAD technique has provided a significant advance in the field of high-temperature Doppler Measurements, extending the temperature range of the measurements by about 1000 deg. K. To the best knowledge of the authors, this is the first study of the Doppler Ratio under partially molten conditions of UO{sub 2}. (author)

  18. H2O temperature sensor for low-pressure flames using tunable diode laser absorption near 2.9 νm

    KAUST Repository

    Li, Sijie

    2011-10-19

    Making use of a newly available rapid-tuning diode laser operating at wavelengths up to 2.9 νm, an absorption-based temperature sensor was developed for in situ measurements in low-pressure flames. Based on the systematic analysis of H2O vapor transitions in the fundamental vibrational bands (ν1 and ν3) of H2O in the range of 2.5-3.0 νm, an optimal closely-spaced spectral line pair near 2.9 νm was selected for its temperature sensitivity in the range of 1000-2500 K. The narrow-linewidth room-temperature laser was scanned repetitively across these spectral features at 5 kHz, enabling fast, accurate temperature sensing. Use of the temperature sensor was investigated in low-pressure flames supported on a McKenna burner at 15, 25 and 60 Torr. To avoid absorption by the cold gases in the flame edges and the recirculation region between the burner and the vacuum chamber wall, a variable-path in situ probe was designed and an optimal path length was determined to accurately measure the flame centerline temperature. Different flame conditions were investigated to illustrate the potential of this sensor system for sensitive measurements of combustion temperature in low-pressure flames. © 2011 IOP Publishing Ltd.

  19. Optimization of reactor power by taking into consideration temperature increase in a reactor pumped 3He-Xe laser

    International Nuclear Information System (INIS)

    Cetin, Fuesun

    2009-01-01

    In nuclear pumped lasers, gas parameters are optimized in a manner such that output power is increased for constructing a high power laser. Since output power increases with the increase of energy deposited in the gas, high output power requires high pumping power. However, the high energy loading results in elevated gas temperature. Temperature increase of this magnitude can detrimentally influence the laser gain and efficiency, since it negatively impacts several important laser kinetic.processes. This fact may cause laser output to abruptly terminate before the peak of the pump pulse [1-3]. A nuclear pumped laser using a volumetric energy source through the 3 He(n, p) 3 H reaction has here been considered. It is assumed that TRIGA Mark II Reactor at Istanbul Technical University is used for nuclear pumping as the neutron source. In the previous papers, the optimal parameters for improving both output power and optical homogeneity were determined [4-5]. Spatial and temporal variations of gas temperature during pumping pulse for maximum peak power (1200 MW) were determined for various operating pressures in Ref. [6]. It was seen that gas temperature reaches up to 1000 0 K near the peak of the pumping pulse for the initial pressures of 1-4 atm. This means that laser output may terminate before the peak of the pump pulse due to overheating of laser gas. Under these conditions, a question arises about a further optimisation taking into consideration gas temperature. This question has been examined in this study. Experimental results (Batyrbekov et al, 1989) showed that temperature rise up to 650 C had no influence on Xe laser characteristics [ 7]. Therefore, It has here been assumed that the lasing will terminate when gas temperature reaches 1000 0 K for a Xe-laser with 3 He buffer gas. Under these conditions optimum reactor power is investigated by taking into consideration lasing duration also. (orig.)

  20. Improved Methodology of MSLB M/E Release Analysis for OPR1000

    International Nuclear Information System (INIS)

    Park, Seok Jeong; Kim, Cheol Woo; Seo, Jong Tae

    2006-01-01

    A new mass and energy (M/E) release analysis methodology for the equipment environmental qualification (EEQ) on loss-of-coolant accident (LOCA) has been recently developed and adopted on small break LOCA EEQ. The new methodology for the M/E release analysis is extended to the M/E release analysis for the containment design for large break LOCA and the main steam line break (MSLB) accident, and named KIMERA (KOPEC Improved Mass and Energy Release Analysis) methodology. The computer code systems used in this methodology is RELAP5K/CONTEMPT4 (or RELAP5-ME) which couples RELAP5/MOD3.1/K with enhanced M/E model and LOCA long term model, and CONTEMPT4/ MOD5. This KIMERA methodology is applied to the MSLB M/E release analysis to evaluate the validation of KIMERA methodology for MSLB in containment design. The results are compared with the OPR 1000 FSAR