WorldWideScience

Sample records for temperatur autoclave me-24

  1. Temperature field investigation of the industrial autoclave ASCAMAT-230

    Directory of Open Access Journals (Sweden)

    Stolyanov A. V.

    2017-09-01

    Full Text Available Heterogeneity of the temperature field in the sterilization chambers of industrial autoclaves during heating and cooling phase is one of the problems in the development of new regime for product heat treatment on the preliminary selection and laboratory testing stages. This is the reason of studying the temperature field of the industrial autoclave ASCAMAT-230. The autoclave ASCAMAT-230 is a vertical autoclave of 230 liters capacity heated by three tubular electric heaters. Determination of temperature field parameters has been carried out according to the method for studying the temperature field of periodic devices' heating medium for sterilizing canned food. Six Thermochron iButton temperature loggers have been used to measure the temperatures in the sterilization chamber of the ASCAMAT-230 autoclave. Logger 1 has been put in the place of the standard thermometer installation, loggers 2 and 3, 5 and 6 – in the center and on periphery of the lower and upper parts of the autoclave respectively, logger 4 – in the center of the middle part of the autoclave's sterilization chamber. Temperature measurement in cans with the product has been carried out by temperature loggers from the Ellab TrackSense PRO complex. The loggers have been installed in two cans with homogeneous product located in the upper and lower parts of the autoclave. The time temperature dependences for the entire sterilization process, as well as for the heating and cooling stages have been constructed according to the acquired information. Based on these data conclusions about the uniformity of the temperature field inside the sterilization chamber of the autoclave ASCAMAT-230 during the heating, sterilization and cooling stages have been developed. Some recommendations for using the autoclave ASCAMAT-230 in the preliminary selection and verification of sterilization regimes for canned foods from hydrobionts, and also for the creation of an industrial autoclave control system

  2. Elevated Temperature, Notched Compression Performance of Out of Autoclave Processed Composites

    Science.gov (United States)

    Grimsley, Brian W.; Sutter, James K.; Dixon, Genevieve D.; Smeltzer, Satn S.

    2013-01-01

    Curved honeycomb sandwich panels composed of carbon fiber reinforced toughened-epoxy polymer facesheets are being evaluated for potential use as payload fairing components on the NASA heavy-lift space launch system (HL-SLS). These proposed composite sandwich panels provide the most efficient aerospace launch structures, and offer mass and thermal advantages when compared with existing metallic payload fairing structures. NASA and industry are investigating recently developed carbon fiber epoxy prepreg systems which can be fabricated using out-of autoclave (OOA) processes. Specifically, OOA processes using vacuum pressure in an oven and thereby significantly reducing the cost associated with manufacturing large (up to 10 m diameter) composite structures when compared with autoclave. One of these OOA composite material systems, CYCOM(R) 5320-1, was selected for manufacture of a 1/16th scale barrel portion of the payload fairing; such that, the system could be compared with the well-characterized prepreg system, CYCOM(R) 977-3, typically processed in an autoclave. Notched compression coupons for each material were obtained from the minimum-gauge flat laminate [60/-60/0]S witness panels produced in this manufacturing study. The coupons were also conditioned to an effective moisture equilibrium point and tested according to ASTM D6484M-09 at temperatures ranging from 25 C up to 177 C. The results of this elevated temperature mechanical characterization study demonstrate that, for thin coupons, the OHC strength of the OOA laminate was equivalent to the flight certified autoclave processed composite laminates; the limitations on the elevated temperature range are hot-wet conditions up to 163 C and are only within the margins of testing error. At 25 C, both the wet and dry OOA material coupons demonstrated greater OHC failure strengths than the autoclave processed material laminates. These results indicate a substantial improvement in OOA material development and

  3. The Development of High Temperature Thermoplastic Composite Materials for Additive Manufactured Autoclave Tooling

    Energy Technology Data Exchange (ETDEWEB)

    Kunc, Vlastimil [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Duty, Chad E. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Lindahl, John M. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Hassen, Ahmed A. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-08-01

    In this work, ORNL and Techmer investigated and screened different high temperature thermoplastic reinforced materials to fabricate composite molds for autoclave processes using Additive Manufacturing (AM) techniques. This project directly led to the development and commercial release of two printable, high temperature composite materials available through Techmer PM. These new materials are targeted for high temperature tooling made via large scale additive manufacturing.

  4. An autoclave treatment reduces the solubility and antigenicity of an allergenic protein found in buckwheat flour.

    Science.gov (United States)

    Tomotake, Hiroyuki; Yamazaki, Rikio; Yamato, Masayuki

    2012-06-01

    The effects of an autoclave treatment of buckwheat flour on a 24-kDa allergenic protein were investigated by measuring reduction in solubility and antibody binding. Sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) analysis showed that the intensity of the major bands, including that of the 24-kDa allergen, was reduced by the autoclave treatment. The protein solubility in buckwheat flour was variably decreased by the autoclave treatment. Enzyme-linked immunosorbent assay analysis using a monoclonal antibody specific for buckwheat 24-kDa protein showed that the reactivity of protein extracts (10 μg/ml) from buckwheat flour was lowered by the autoclave treatment. The autoclave treatment may reduce the major allergen content of buckwheat. Future studies will determine if autoclaving treatments affect the allergenicity of the 24-kDa buckwheat protein.

  5. Out-of-Autoclave Cure Composites

    Science.gov (United States)

    Hayes, Brian S.

    2015-01-01

    As the size of aerospace composite parts exceeds that of even the largest autoclaves, the development of new out-of-autoclave processes and materials is necessary to ensure quality and performance. Many out-of-autoclave prepreg systems can produce high-quality composites initially; however, due to long layup times, the resin advancement commonly causes high void content and variations in fiber volume. Applied Poleramic, Inc. (API), developed an aerospace-grade benzoxazine matrix composite prepreg material that offers more than a year out-time at ambient conditions and provides exceptionally low void content when out-of-autoclave cured. When compared with aerospace epoxy prepreg systems, API's innovation offers significant improvements in terms of out-time at ambient temperature and the corresponding tack retention. The carbon fiber composites developed with the optimized matrix technology have significantly better mechanical performance in terms of hot-wet retention and compression when compared with aerospace epoxy matrices. These composites also offer an excellent overall balance of properties. This matrix system imparts very low cure shrinkage, low coefficient of thermal expansion, and low density when compared with most aerospace epoxy prepreg materials.

  6. Single Vacuum Bagging and Autoclave Curing System Influence on Physical and Mechanical Properties of Phenolic Composites

    Directory of Open Access Journals (Sweden)

    M.A. Mirzapour

    2010-12-01

    Full Text Available Industrial production of thermoset composite components involves the application of a vacuum bagging and autoclave pressure to minimize void percentage, usually to less than 5%. Phenolic resin systems generate water as a reaction byproduct via condensation reactions during curing at elevated temperatures. In this paper, vacuum bagging and simple manufactured autoclave curing systems are used for manufacturing of asbestos/phenolic composites and the effects of processing conditions on manufactured composites are investigated. The traditional single-vacuum-bag process is unable to manage the volatiles effectively, resulting in inferior laminates having voids. The autoclave process cure cycle (temperature/pressure profiles for the selected composite system is designed to emit volatiles during curing reactions effectively and produce composites with low void contents and excellent mechanical properties. Laminate consolidation quality is characterized by optical photomicrography for the cross-sections and measurements of void content and mechanical properties. The void content of phenolic composites as opposed to other composites increases as pressure increases up to 3 bar and it is then decreased beyond it. A product of 124% lower void content, 13% higher density, 24% higher flexural strength and 27% higher flexural modulus can be fabricated in composites obtainedby autoclave processing.

  7. Autoclave cycle optimization for high performance composite parts manufacturing

    OpenAIRE

    Nele, L.; Caggiano, A.; Teti, R.

    2016-01-01

    In aeronautical production, autoclave curing of composite parts must be performed according to a specified diagram of temperature and pressure vs time. Part-tool assembly thermal inertia and shape have a large influence on the heating and cooling rate, and therefore on the dwell time within the target temperature range. When simultaneously curing diverse composite parts, the total autoclave cycle time is driven by the part-tool assembly with the lower heating and cooling rates. With the aim t...

  8. Out-of-Autoclave Manufacturing of Aerospace Representative Parts

    Science.gov (United States)

    Cauberghs, Julien

    The use of carbon fibre reinforced composites for aerospace structures has seen a high increase in recent years, and is still growing. The high stiffness-to-weight ratio of these materials makes them ideal for primary structures on airplanes, satellites, and spacecrafts. Nevertheless, the manufacturing of composites remains very costly since it requires equipment investment such as an autoclave, and very qualified workers. Out-of-autoclave manufacturing technology is very promising since it only requires a traditional oven, while still aiming at similar part quality. However, the absence of positive pressure compared with an autoclave makes it more difficult to achieve low porosity parts. This research investigates the manufacturing of complex features with out-of autoclave prepreg technology. The features studied are tight-radius corners with a curvature change, and ply drop-offs. Ply drop-offs tests were conducted to identify if porosity is higher at ply terminations. In corners, the bagging arrangement was modified to achieve the most uniform thickness in areas of curvature change, even with small radii. The conclusions from these studies provided us with guidelines to manufacture larger representative parts, which included these features. The representative parts were tested for porosity, thickness uniformity, mechanical performance, and glass transition temperature (Tg). A total of four representative parts were manufactured with out-of-autoclave technology, and one more was manufactured with an autoclave to allow for a proper comparison between the two processes. The materials used were MTM45-1 5 harness satin and CYCOM5320 plain weave for the out-of-autoclave parts, and CYCOM5276-1 plain weave for the autoclave part. The effect of ply drop-offs on porosity was found to be negligible. Thickness deviation in corners was attributed to a combination of consumable bridging, prepreg's bulk factor and inter-ply shear. Overall, out-of-autoclave prepregs showed

  9. Autoclave decomposition method for metals in soils and sediments.

    Science.gov (United States)

    Navarrete-López, M; Jonathan, M P; Rodríguez-Espinosa, P F; Salgado-Galeana, J A

    2012-04-01

    Leaching of partially leached metals (Fe, Mn, Cd, Co, Cu, Ni, Pb, and Zn) was done using autoclave technique which was modified based on EPA 3051A digestion technique. The autoclave method was developed as an alternative to the regular digestion procedure passed the safety norms for partial extraction of metals in polytetrafluoroethylene (PFA vessel) with a low constant temperature (119.5° ± 1.5°C) and the recovery of elements were also precise. The autoclave method was also validated using two Standard Reference Materials (SRMs: Loam Soil B and Loam Soil D) and the recoveries were equally superior to the traditionally established digestion methods. Application of the autoclave was samples from different natural environments (beach, mangrove, river, and city soil) to reproduce the recovery of elements during subsequent analysis.

  10. Destruction of spores on building decontamination residue in a commercial autoclave.

    Science.gov (United States)

    Lemieux, P; Sieber, R; Osborne, A; Woodard, A

    2006-12-01

    The U.S. Environmental Protection Agency conducted an experiment to evaluate the effectiveness of a commercial autoclave for treating simulated building decontamination residue (BDR). The BDR was intended to simulate porous materials removed from a building deliberately contaminated with biological agents such as Bacillus anthracis (anthrax) in a terrorist attack. The purpose of the tests was to assess whether the standard operating procedure for a commercial autoclave provided sufficiently robust conditions to adequately destroy bacterial spores bound to the BDR. In this study we investigated the effects of several variables related to autoclaving BDR, including time, temperature, pressure, item type, moisture content, packing density, packing orientation, autoclave bag integrity, and autoclave process sequence. The test team created simulated BDR from wallboard, ceiling tiles, carpet, and upholstered furniture, and embedded in the BDR were Geobacillus stearothermophilus biological indicator (BI) strips containing 10(6) spores and thermocouples to obtain time and temperature profile data associated with each BI strip. The results indicated that a single standard autoclave cycle did not effectively decontaminate the BDR. Autoclave cycles consisting of 120 min at 31.5 lb/in2 and 275 degrees F and 75 min at 45 lb/in2 and 292 degrees F effectively decontaminated the BDR material. Two sequential standard autoclave cycles consisting of 40 min at 31.5 lb/in2 and 275 degrees F proved to be particularly effective, probably because the second cycle's evacuation step pulled the condensed water out of the pores of the materials, allowing better steam penetration. The results also indicated that the packing density and material type of the BDR in the autoclave could have a significant impact on the effectiveness of the decontamination process.

  11. Effect of autoclave induced low-temperature degradation on the adhesion energy between yttria-stabilized zirconia veneered with porcelain.

    Science.gov (United States)

    Li, Kai Chun; Waddell, J Neil; Prior, David J; Ting, Stephanie; Girvan, Liz; van Vuuren, Ludwig Jansen; Swain, Michael V

    2013-11-01

    To investigate the effect of autoclave induced low-temperature degradation on the adhesion energy between yttria-stabilized zirconia veneered with porcelain. The strain energy release rate using a four-point bending stable fracture test was evaluated for two different porcelains [leucite containing (VM9) and glass (Zirox) porcelain] veneered to zirconia. Prior to veneering the zirconia had been subjected to 0 (control), 1, 5, 10 and 20 autoclave cycles. The specimens were manufactured to a total bi-layer dimension of 30 mm × 8 mm × 3 mm. Subsequent scanning electron microscopy/energy dispersive spectrometry, electron backscatter diffraction and X-ray diffraction analysis were performed to identify the phase transformation and fracture behavior. The strain energy release rate for debonding of the VM9 specimens were significantly higher (pautoclave cycles lowered the strain energy release rate significantly (pautoclave cycles between 5 and 20. The monoclinic phase reverted back to tetragonal phase after undergoing conventional porcelain firing cycles. EBSD data showed significant changes of the grain size distribution between the control and autoclaved specimen (cycle 20). Increasing autoclave cycles only significantly decreased the adhesion of the VM9 layered specimens. In addition, a conventional porcelain firing schedule completely reverted the monoclinic phase back to tetragonal. Copyright © 2013 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  12. Leaching of a copper flotation concentrate with ammonium persulfate in an autoclave system

    Science.gov (United States)

    Deniz Turan, M.; Soner Altundoğan, H.

    2014-09-01

    The leaching behavior of a copper flotation concentrate was investigated using ammonium persulfate (APS) in an autoclave system. The decomposition products of APS, active oxygen, and acidic medium were used to extract metals from the concentrate. Leaching experiments were performed to compare the availability of APS as an oxidizing agent for leaching of the concentrate under atmospheric conditions and in an autoclave system. Leaching temperature and APS concentration were found to be important parameters in both leaching systems. Atmospheric leaching studies showed that the metal extractions increased with the increase in APS concentration and temperature (up to 333 K). A similar tendency was determined in the autoclave studies up to 423 K. It was also determined that the metal extractions decreased at temperatures above 423 K due to the passivation of the particle surface by molten elemental sulfur. The results showed that higher copper extractions could be achieved using an autoclave system.

  13. Elevated Temperature, Residual Compressive Strength of Impact-Damaged Sandwich Structure Manufactured Out-of-Autoclave

    Science.gov (United States)

    Grimsley, Brian W.; Sutter, James K.; Burke, Eric R.; Dixon, Genevieve D.; Gyekenyesi, Thomas G.; Smeltzer, Stanley S.

    2012-01-01

    Several 1/16th-scale curved sandwich composite panel sections of a 10 m diameter barrel were fabricated to demonstrate the manufacturability of large-scale curved sections using minimum gauge, [+60/-60/0]s, toughened epoxy composite facesheets co-cured with low density (50 kilograms per cubic meters) aluminum honeycomb core. One of these panels was fabricated out of autoclave (OoA) by the vacuum bag oven (VBO) process using Cycom(Registered Trademark) T40-800b/5320-1 prepreg system while another panel with the same lay-up and dimensions was fabricated using the autoclave-cure, toughened epoxy prepreg system Cycom(Registered Trademark) IM7/977-3. The resulting 2.44 m x 2 m curved panels were investigated by non-destructive evaluation (NDE) at NASA Langley Research Center (NASA LaRC) to determine initial fabrication quality and then cut into smaller coupons for elevated temperature wet (ETW) mechanical property characterization. Mechanical property characterization of the sandwich coupons was conducted including edge-wise compression (EWC), and compression-after-impact (CAI) at conditions ranging from 25 C/dry to 150 C/wet. The details and results of this characterization effort are presented in this paper.

  14. Autoclave nuclear criticality safety analysis

    Energy Technology Data Exchange (ETDEWEB)

    D`Aquila, D.M. [Martin Marietta Energy Systems, Inc., Piketon, OH (United States); Tayloe, R.W. Jr. [Battelle, Columbus, OH (United States)

    1991-12-31

    Steam-heated autoclaves are used in gaseous diffusion uranium enrichment plants to heat large cylinders of UF{sub 6}. Nuclear criticality safety for these autoclaves is evaluated. To enhance criticality safety, systems are incorporated into the design of autoclaves to limit the amount of water present. These safety systems also increase the likelihood that any UF{sub 6} inadvertently released from a cylinder into an autoclave is not released to the environment. Up to 140 pounds of water can be held up in large autoclaves. This mass of water is sufficient to support a nuclear criticality when optimally combined with 125 pounds of UF{sub 6} enriched to 5 percent U{sup 235}. However, water in autoclaves is widely dispersed as condensed droplets and vapor, and is extremely unlikely to form a critical configuration with released UF{sub 6}.

  15. Humid Heat Autoclaving of Hybrid Nanoparticles Achieved by Decreased Nanoparticle Concentration and Improved Nanoparticle Stability Using Medium Chain Triglycerides as a Modifier.

    Science.gov (United States)

    Gou, Jingxin; Chao, Yanhui; Liang, Yuheng; Zhang, Ning; He, Haibing; Yin, Tian; Zhang, Yu; Xu, Hui; Tang, Xing

    2016-09-01

    Humid heat autoclaving is a facile technique widely used in the sterilization of injections, but the high temperature employed would destroy nanoparticles composed of biodegradable polymers. The aim of this study was to investigate whether incorporation of medium chain triglycerides (MCT) could stabilize nanoparticles composed of poly (ethylene glycol)-b-polycaprolactone (PEG-b-PCL) during autoclaving (121°C, 10 min). Polymeric nanoparticles with different MCT contents were prepared by dialysis. Block copolymer degradation was studied by GPC. The critical aggregation concentrations of nanoparticles at different temperatures were determined using pyrene fluorescence. The size, morphology and weight averaged molecular weight of pristine/autoclaved nanoparticles were studied using DLS, TEM and SLS, respectively. Drug loading content and release profile were determined using RP-HPLC. The protecting effect of MCT on nanoparticles was dependent on the amount of MCT incorporated. Nanoparticles with high MCT contents, which assumed an emulsion-like morphology, showed reduced block copolymer degradation and particle disassociation after incubation at 100°C for 24 h. Nanoparticles with high MCT content showed the lowest critical aggregation concentration (CAC) under either room temperature or 60°C and the lowest particle concentration among all samples. And the particle size, drug loading content, physical stability and release profile of nanoparticles with high MCT contents remained nearly unchanged after autoclaving. Incorporation of high amount of MCT changed the morphology of PEG-b-PCL based nanoparticles to an emulsion-like structure and the nanoparticles prepared could withstand autoclaving due to improved particle stability and decreased particle concentration caused by MCT incorporation.

  16. Flash autoclave settings may influence eradication but not presence of well-established biofilms on orthopaedic implant material.

    Science.gov (United States)

    Williams, Dustin L; Taylor, Nicholas B; Epperson, Richard T; Rothberg, David L

    2017-10-04

    Flash autoclaving is one of the most frequently utilized methods of sterilizing devices, implants or other materials. For a number of decades, it has been common practice for surgeons to remove implantable devices, flash autoclave and then reimplant them in a patient. Data have not yet indicated the potential for biofilms to survive or remain on the surface of orthopaedic-relevant materials following flash autoclave. In this study, monomicrobial and polymicrobial biofilms were grown on the surface of clinically relevant titanium materials and exposed to flash autoclave settings that included varying times and temperatures. Data indicated that when the sterilization and control temperatures of an autoclave were the same, biofilms were able to survive flash autoclaving that was performed for a short duration. Higher temperature and increased duration rendered biofilms non-viable, but none of the autoclave settings had the ability to remove or disperse the presence of biofilms from the titanium surfaces. These findings may be beneficial for facilities, clinics, or hospitals to consider if biofilms are suspected to be present on materials or devices, in particular implants that have had associated infection and are considered for re-implantation. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  17. Outgassing of Out-of-Autoclave Composite Primary Structures for Small Satellites

    Science.gov (United States)

    Komus, Alastair

    Out-of-autoclave vacuum-bagged-only (VBO) processing is capable of producing lower cost composite primary structures for small satellites than autoclave processing. However, the outgassing performance of VBO structures in a vacuum environment has not been examined. Panels were manufactured from CYCOM 5320-1 and TC275-1 carbon fiber/epoxy prepreg using VBO processing. The humidity level, pre-cure dwell time, and cure cycle parameters were varied during manufacturing. The degree of cure and glass transition temperature were shown to increase with increasing oven temperature. Processing humidity levels and the length of pre-cure dwell times had no discernable effect on the total mass loss (TML) and collected volatile condensable material (CVCM) that were outgassed under vacuum. Instead the TML was controlled by moisture saturation after manufacturing. Fourier transform infrared spectroscopy showed that epoxy oligomers were the primary CVCM. The study showed the VBO laminates had outgassing values that were comparable to the autoclave-cured laminates.

  18. Mathematical Model For Autoclave Curing Of Unsaturated Polyester Based Composite Materials

    Directory of Open Access Journals (Sweden)

    Adnan A. Abdul Razak

    2013-05-01

    Full Text Available Heat transfer process involved in the autoclave curing of fiber-reinforced thermosetting composites is investigated numerically. A model for the prediction of the temperature and the extent of the reaction across the laminate thickness during curing process in the autoclave of unsaturated polyester based composite has been developed. The governing equation for one dimensional heat transfer, and accounting for the heat generation due to the exothermic cure reaction in the composites had been used.  It was found that the temperature at the central of the laminate increases up to the external imposed temperature, because of the thermal conductivity of the resin and fiber. The heat generated by the exothermic reaction of the resin is not adequately removed; the increase in the temperature at the center increases the resins rate reaction, which in turn generates more heat.

  19. Synthesis and characterization of strontium carboxylates at room temperature and at high temperature in autoclave vessels

    DEFF Research Database (Denmark)

    Christgau, Stephan; Ståhl, Kenny; Andersen, Jens Enevold Thaulov

    2006-01-01

    A novel method was developed for synthesis of strontium coordination compounds in high yields. The synthesis proceeded along three pathways that provided strontium salts in high purity and high yields, close to 100%, as confirmed by flame atomic absorption spectroscopy (FAAS) and powder x......-ray crystallography. Optimum conditions were found at T = 120-1400C, a base-to-acid ratio of 1.2 and 15 min. of reaction-time in an autoclave vessel. Large crystals were readily obtained within a time period of hours. The crystal structures of strontium D-glutamate hexahydrate (I) and strontium di-(hydrogen L......-glutamate) pentahydrate (II) were confirmed by X-ray powder diffraction at 295 K and Rietveld refinements (I: Space group P212121, Z=4, a=7.3519(2), b=8.7616(2), c=20.2627(5) Å, and II: Space group P21, Z=2, a=8.7243(1), b=7.2635(1), c=14.6840(2) Å, β=100.5414(7) °). Synthesis at room temperature provided four additional...

  20. Cure Cycle Optimization of Rapidly Cured Out-Of-Autoclave Composites

    Science.gov (United States)

    Dong, Anqi; Zhao, Yan; Zhao, Xinqing; Yu, Qiyong

    2018-01-01

    Out-of-autoclave prepreg typically needs a long cure cycle to guarantee good properties as the result of low processing pressure applied. It is essential to reduce the manufacturing time, achieve real cost reduction, and take full advantage of out-of-autoclave process. The focus of this paper is to reduce the cure cycle time and production cost while maintaining high laminate quality. A rapidly cured out-of-autoclave resin and relative prepreg were independently developed. To determine a suitable rapid cure procedure for the developed prepreg, the effect of heating rate, initial cure temperature, dwelling time, and post-cure time on the final laminate quality were evaluated and the factors were then optimized. As a result, a rapid cure procedure was determined. The results showed that the resin infiltration could be completed at the end of the initial cure stage and no obvious void could be seen in the laminate at this time. The laminate could achieve good internal quality using the optimized cure procedure. The mechanical test results showed that the laminates had a fiber volume fraction of 59–60% with a final glass transition temperature of 205 °C and excellent mechanical strength especially the flexural properties. PMID:29534048

  1. Effects of steam autoclave treatment on Geobacillus stearothermophilus spores.

    Science.gov (United States)

    Huesca-Espitia, L C; Suvira, M; Rosenbeck, K; Korza, G; Setlow, B; Li, W; Wang, S; Li, Y-Q; Setlow, P

    2016-11-01

    To determine the mechanism of autoclave killing of Geobacillus stearothermophilus spores used in biological indicators (BIs) for steam autoclave sterilization, and rates of loss of spore viability and a spore enzyme used in BIs. Spore viability, dipicolinic acid (DPA) release, nucleic acid staining, α-glucosidase activity, protein structure and mutagenesis were measured during autoclaving of G. stearothermophilus spores. Loss of DPA and increases in spore core nucleic acid staining were slower than loss of spore viability. Spore core α-glucosidase was also lost more slowly than spore viability, although soluble α-glucosidase in spore preparations was lost more rapidly. However, spores exposed to an effective autoclave sterilization lost all viability and α-glucosidase activity. Apparently killed autoclaved spores were not recovered by artificial germination in supportive media, much spore protein was denatured during autoclaving, and partially killed autoclave-treated spore preparations did not acquire mutations. These results indicate that autoclave-killed spores cannot be revived, spore killing by autoclaving is likely by protein damage, and spore core α-glucosidase activity is lost more slowly than spore viability. This work provides insight into the mechanism of autoclave killing of spores of an organism used in BIs, and that a spore enzyme in a BI is more stable to autoclaving than spore viability. © 2016 The Society for Applied Microbiology.

  2. Identification of autoclave-resistant Anisakis simplex allergens.

    Science.gov (United States)

    Carballeda-Sangiao, Noelia; Olivares, Fabiola; Rodriguez-Mahillo, Ana I; Careche, Mercedes; Tejada, Margarita; Moneo, Ignacio; González-Muñoz, Miguel

    2014-04-01

    Anisakis simplex is a fish parasite able to induce allergic reactions in humans infected when eating raw or undercooked fish parasitized with viable third-stage larvae. Some authors claim that exposure to nonviable Anisakis material can result in allergic symptoms in previously sensitized patients, indicating that parasite allergens are resistant to the thermal treatments of usual cooking procedures. Furthermore, some patients report symptoms after eating canned fish. The aim of this work was the analysis of parasite allergen stability in heating to 121 °C in an autoclave to simulate the thermal process applied to canned fish. Third-stage larvae were subjected to autoclaving for 20, 40, and 80 min, and parasite crude extracts were analyzed by electrophoresis, immunoblotting, and a flow-cytometric basophil activation test. Allergens resistant to autoclaving were separated by reversed-phase high-performance liquid chromatography and identified by ion trap mass spectrometry. Protein analysis by sodium dodecyl sulfate-polyacrylamide gel electrophoresis showed that autoclaving considerably reduced the number and intensity of identifiable protein bands in a time-dependent manner. Several allergens were detected by immunoblotting with a pool of A. simplex allergic patients' sera after autoclaving. Allergens of 9 and 14 kDa resistant to autoclaving were identified as Ani s 4 and Ani s 1 allergens, respectively. Functional analysis showed that allergens retain their capacity to activate basophils even after autoclaving for 80 min. In conclusion, some relevant A. simplex allergens retain their capacity to bind immunoglobulin E and activate basophils after being subjected to autoclaving, which is a method equivalent to that used in industrial canning processes.

  3. Face-Sheet Quality Analysis and Thermo-Physical Property Characterization of OOA and Autoclave Panels

    Science.gov (United States)

    Miller, Sandi G.; Lort, Richard D., III; Zimmerman, Thomas J.; Sutter, James K.; Pelham, Larry I.; McCorkle, Linda S.; Scheiman, Daniel A.

    2012-01-01

    Increased application of polymer matrix composite (PMC) materials in large vehicle structures requires consideration of non-autoclave manufacturing technology. The NASA Composites for Exploration project, and its predecessor, Lightweight Spacecraft Structures and Materials project, were tasked with the development of materials and manufacturing processes for structures that will perform in a heavy-lift-launch vehicle environment. Both autoclave and out of autoclave processable materials were considered. Large PMC structures envisioned for such a vehicle included the payload shroud and the interstage connector. In this study, composite sandwich panels representing 1/16th segments of the barrel section of the Ares V rocket fairing were prepared as 1.8 m x 2.4 m sections of the 10 m diameter arc segment. IM7/977-3 was used as the face-sheet prepreg of the autoclave processed panels and T40-800B/5320-1 for the out of autoclave panels. The core was 49.7 kg/sq m (3.1 lb/cu ft (pcf)) aluminum honeycomb. Face-sheets were fabricated by automated tape laying 153 mm wide unidirectional tape. This work details analysis of the manufactured panels where face-sheet quality was characterized by optical microscopy, cured ply thickness measurements, acid digestion, and thermal analysis.

  4. Curing Pressure Influence of Out-of-Autoclave Processing on Structural Composites for Commercial Aviation

    Directory of Open Access Journals (Sweden)

    Vasileios M. Drakonakis

    2013-01-01

    Full Text Available Autoclaving is a process that ensures the highest quality of carbon fiber reinforced polymer (CFRP composite structures used in aviation. During the autoclave process, consolidation of prepreg laminas through simultaneous elevated pressure and temperature results in a uniform high-end material system. This work focuses on analyzing in a fundamental way the applications of pressure and temperature separately during prepreg consolidation. A controlled pressure vessel (press-clave has been designed that applies pressure during the curing process while the temperature is being applied locally by heat blankets. This vessel gives the ability to design manufacturing processes with different pressures while applying temperature at desired regions of the composite. The pressure role on the curing extent and its effect on the interlayer region are also tested in order to evaluate the consolidation of prepregs to a completely uniform material. Such studies may also be used to provide insight into the morphology of interlayer reinforcement concepts, which are widely used in the featherweight composites. Specimens manufactured by press-clave, which separates pressure from heat, are analytically tested and compared to autoclaved specimens in order to demonstrate the suitability of the press-clave to manufacture high-quality composites with excessively reduced cost.

  5. An in situ synchrotron energy-dispersive diffraction study of the hydration of oilwell cement systems under high temperature/autoclave conditions up to 130 deg. C

    International Nuclear Information System (INIS)

    Colston, Sally L.; Barnes, Paul; Jupe, Andrew C.; Jacques, Simon D.M.; Hall, Christopher; Livesey, Paul; Dransfield, John; Meller, Nicola; Maitland, Geoffrey C.

    2005-01-01

    The technique of synchrotron energy dispersive diffraction has been developed for in situ studies of cement hydration under autoclave conditions. This has been applied to oilwell cements hydrating at typical oilwell temperatures up to 130 deg. C. The results show clearly the detailed interplay between 11 detectable phases, from which a phase transformation scheme has been derived; this illustrates the progression of hydration up to 130 deg. C for two extreme cases, with and without conservation of water content and autoclave pressure. The monosulphate hydrate phases are found to exhibit different stability bounds, with a surprising sequence of the 14-water, 10-water then 12-water monosulphate as temperature/time increases; the latter form is particularly associated with conditions of water/pressure loss. The effect of retarders on C 3 S dissolution and CH formation is negligible above 70 deg. C, whereas the effect on the calcium sulphoaluminate hydrates is more complex, and possible reasons for this are discussed

  6. The experimental study of heat transfer around molds inside a model autoclave

    Science.gov (United States)

    Ghamlouch, Taleb; Roux, Stéphane; Lefèvre, Nicolas; Bailleul, Jean-Luc; Sobotka, Vincent

    2018-05-01

    The temperature distribution within composite parts manufactured inside autoclaves plays a key role in determining the parts quality at the end of the curing cycle. Indeed, heat transfer between the parts and the surroundings inside an autoclave is strongly coupled with the flow field around the molds and can be modeled through the convective heat transfer coefficient (HTC). The aerodynamically unsuitable geometry of the molds generates complex turbulent non-uniform flows around them accompanied with the presence of dead zones. This heterogeneity can imply non-uniform convective heat transfers leading to temperature gradients inside parts that can be prejudicial. Given this fact, the purpose of this study is to perform experimental measurements in order to describe the flow field and the convective heat transfer behavior around representative industrial molds installed inside a home-made model. A key point of our model autoclave is the ease of use of non-intrusive measuring instruments: the Particle Image Velocimetry (PIV) technique and infrared imaging camera for the study of the flow field and the heat transfer coefficient distribution around the molds respectively. The experimental measurements are then compared to computational fluid dynamics (CFD) calculations performed on the computer code ANSYS Fluent 16.0®. This investigation has revealed, as expected, a non-uniform distribution of the convective heat transfer coefficient around the molds and therefore the presence of thermal gradients which can reduce the composite parts quality during an autoclave process. A good agreement has been achieved between the experimental and the numerical results leading then to the validation of the performed numerical simulations.

  7. An autoclave system for uranium oxide dissolution experiments

    International Nuclear Information System (INIS)

    Nykyri, Mikko

    1985-05-01

    According to the decision in principle of the Council of State of Finland the nuclear energy producers must provide preparedness for carrying out the final disposal of spent nuclear fuel in Finland. By the present principal concept the spent fuel will be disposed deep into the granitic bedrock. A parameter needed by risk analysis models is the dissolution rate of the uranium oxide matrix in the fuel pellets. In order to approach conditions prevailing deep in the groundwater, and autoclave system for dissolution experiments was developed at the Technical Research Centre of Finland. The low oxygen content and high pressure at elevated temperatures are simulated in the system. 20 MPa and 100 deg C are the upper operation limits of pressure and temperature. Water can be changed in the experiment autoclave without remarkable pressure and temperature variations. This has been arranged by using three pressure vessels: a supply vessel, a dissolution vessel and a depletion vessel. The extreme vessels serve pressure balancing purposes during water exchange. The water is deoxygenated during a preparation phase in the supply vessel by flushing it with nitrogen gas. Polytetrafluoroethylene is the principal material in contact with the water. A redox electrode couple was developed for potential measurements inside the dissolution vessel. The reference electrode is of Ag/AgCl-type with saturated KC1 electrolyte. A platinum wire operates as a measuring electrode

  8. Compact solar autoclave based on steam generation using broadband light-harvesting nanoparticles.

    Science.gov (United States)

    Neumann, Oara; Feronti, Curtis; Neumann, Albert D; Dong, Anjie; Schell, Kevin; Lu, Benjamin; Kim, Eric; Quinn, Mary; Thompson, Shea; Grady, Nathaniel; Nordlander, Peter; Oden, Maria; Halas, Naomi J

    2013-07-16

    The lack of readily available sterilization processes for medicine and dentistry practices in the developing world is a major risk factor for the propagation of disease. Modern medical facilities in the developed world often use autoclave systems to sterilize medical instruments and equipment and process waste that could contain harmful contagions. Here, we show the use of broadband light-absorbing nanoparticles as solar photothermal heaters, which generate high-temperature steam for a standalone, efficient solar autoclave useful for sanitation of instruments or materials in resource-limited, remote locations. Sterilization was verified using a standard Geobacillus stearothermophilus-based biological indicator.

  9. Compact solar autoclave based on steam generation using broadband light-harvesting nanoparticles

    Science.gov (United States)

    Neumann, Oara; Feronti, Curtis; Neumann, Albert D.; Dong, Anjie; Schell, Kevin; Lu, Benjamin; Kim, Eric; Quinn, Mary; Thompson, Shea; Grady, Nathaniel; Nordlander, Peter; Oden, Maria; Halas, Naomi J.

    2013-01-01

    The lack of readily available sterilization processes for medicine and dentistry practices in the developing world is a major risk factor for the propagation of disease. Modern medical facilities in the developed world often use autoclave systems to sterilize medical instruments and equipment and process waste that could contain harmful contagions. Here, we show the use of broadband light-absorbing nanoparticles as solar photothermal heaters, which generate high-temperature steam for a standalone, efficient solar autoclave useful for sanitation of instruments or materials in resource-limited, remote locations. Sterilization was verified using a standard Geobacillus stearothermophilus-based biological indicator. PMID:23836642

  10. Preparation of TiO2 thin films from autoclaved sol containing needle-like anatase crystals

    International Nuclear Information System (INIS)

    Ge Lei; Xu Mingxia; Fang Haibo; Sun Ming

    2006-01-01

    A new inorganic sol-gel method was introduced in this paper to prepare TiO 2 thin films. The autoclaved sol with needle-like anatase crystals was synthesized using titanyl sulfate (TiOSO 4 ) and peroxide (H 2 O 2 ) as starting materials. The transparent anatase TiO 2 thin films were prepared on glass slides from the autoclaved sol by sol-gel dip-coating method. A wide range of techniques such as Fourier transform infrared transmission spectra (FT-IR), X-ray diffraction (XRD), thermogravimetry-differential thermal analysis (TG-DTA), scanning electron microscopes, X-ray photoelectron spectroscopy (XPS) and ultraviolet-visible spectrum were applied to characterize the autoclaved sol and TiO 2 thin films. The results indicate that the autoclaved sol is flavescent, semitransparent and stable at room temperature. The anatase crystals of TiO 2 films connect together to form net-like structure after calcined and the films become uniform with increasing heating temperature. The surface of the TiO 2 films contain not only Ti and O elements, but also a small amount of N and Na elements diffused from substrates during heat treatment. The TiO 2 films are transparent and their maximal light transmittances exceed 80% under visible light region

  11. Compaction behavior of out-of-autoclave prepreg materials

    Science.gov (United States)

    Serrano, Léonard; Olivier, Philippe; Cinquin, Jacques

    2017-10-01

    The main challenges with composite parts manufacturing are related to the curing means, mainly autoclaves, the length of their cycles and their operating costs. In order to decrease this dependency, out of autoclave materials have been considered as a solution for high production rate parts such as spars, flaps, etc… However, most out-of-autoclave process do not possess the same maturity as their counterpart, especially concerning part quality1. Some pre-cure processes such as compaction and ply lay-up are usually less of a concern for autoclave manufacturing: the pressure applied during the cycle participates to reduce the potential defects (porosity caused by a poor quality lay-up, bad compaction, entrapped air or humidity…). For out-of-autoclave parts, those are crucial steps which may have many consequences on the final quality of the laminate2. In order to avoid this quality loss, those steps must be well understood.

  12. Evaluation of Out-of-Autoclave (OOA epoxy system

    Directory of Open Access Journals (Sweden)

    Fernanda Guilherme

    Full Text Available Abstract Epoxy resins (EP usually cure in autoclave to minimize resin voids and to achieve the desired resin/fiber ratio. Cure parameters such as temperature, vacuum and pressure levels are controlled and monitored. Aiming time and cost optimization, new out-of-autoclave (OOA cure processes have been developed lately. This study evaluated the cure cycle and the effect of non-programmed interruptions in an OOA process. Fourier Transform Infrared spectroscopy (FT-IR results show similarities between the resin used and diglycidyl ether of bisphenol A (DGEBA and also that the curing system is composed of cyan and sulfur hardeners, codified in industry, as Components of #2511 Resin System. The cure cycle and its interruptions were simulated by dynamic-mechanical analysis (DMA. The samples obtained were evaluated by FT-IR and differential scanning calorimetry (DSC, whose results show that the degree of cure varying between 0.8 to 0.85 was achieved at 120 °C.

  13. Characterization and behaviour of Autoclaved Aerated Concrete before Autoclaving

    NARCIS (Netherlands)

    Straub, Chr.; Florea, M.V.A.; Brouwers, H.J.H.; Schmidt, Wolfram; Msinjili, Nsesheye Susan

    In order to achieve a high quality Autoclaved Aerated Concrete (AAC) product, certain steps need to be ensured: the characterization of the raw materials, a proper mixing and correct slurry behaviour to achieve a good green body during green curing. In the current research the emphasis is on all of

  14. No-Oven, No-Autoclave Composite Processing

    Science.gov (United States)

    Rauscher, Michael D.

    2015-01-01

    Very large composite structures, such as those used in NASA's Space Launch System, push the boundaries imposed by current autoclaves. New technology is needed to maintain composite performance and free manufacturing engineers from the restraints of curing equipment size limitations. Recent efforts on a Phase II project by Cornerstone Research Group, Inc. (CRG), have advanced the technology and manufacturing readiness levels of a unique two-part epoxy resin system. Designed for room-temperature infusion of a dry carbon preform, the system includes a no-heat-added cure that delivers 350 F composite performance in a matter of hours. This no-oven, no-autoclave (NONA) composite processing eliminates part-size constraints imposed by infrastructure and lowers costs by increasing throughput and reducing capital-specific, process-flow bottlenecks. As a result of the Phase II activity, NONA materials and processes were used to make high-temperature composite tooling suitable for further production of carbon-epoxy laminates and honeycomb/ sandwich-structure composites with an aluminum core. The technology platform involves tooling design, resin infusion processing, composite part design, and resin chemistry. The various technology elements are combined to achieve a fully cured part. The individual elements are not unusual, but they are combined in such a way that enables proper management of the heat generated by the epoxy resin during cure. The result is a self-cured carbon/ epoxy composite part that is mechanically and chemically stable at temperatures up to 350 F. As a result of the successful SBIR effort, CRG has launched NONA Composites as a spinoff subsidiary. The company sells resin to end users, fabricates finished goods for customers, and sells composite tooling made with NONA materials and processes to composite manufacturers.

  15. Surface roughness of polyvinyl siloxane impression materials following chemical disinfection, autoclave and microwave sterilization.

    Science.gov (United States)

    Al Kheraif, Abdulaziz Abdullah

    2013-05-01

    Autoclave sterilization and microwave sterilization has been suggested as the effective methods for the disinfection of elastomeric impressions, but subjecting elastomeric impressions to extreme temperature may have adverse effects on critical properties of the elastomers. To evaluate the effect of chemical disinfection as well as autoclave and microwave sterilization on the surface roughness of elastomeric impression materials. The surface roughness of five commercially available polyvinyl siloxane impression materials (Coltene President, Affinis Perfect impression, Aquasil, 3M ESPE Express and GC Exafast) were evaluated after subjecting them to chemical disinfection, autoclaving and microwave sterilization using a Talysurf Intra 50 instrument. Twenty specimens from each material were fabricated and divided into four equal groups, three experimental and one control (n=25). The differences in the mean surface roughness between the treatment groups were recorded and statistically analyzed. No statistically significant increase in the surface roughness was observed when the specimens were subjected to chemical disinfection and autoclave sterilization, increase in roughness and discoloration was observed in all the materials when specimens were subjected to microwave sterilization. Chemical disinfection did not have a significant effect but, since it is less effective, autoclave sterilization can be considered effective and autoclaving did not show any specimen discoloration as in microwave sterilization. Microwave sterilization may be considered when impressions are used to make diagnostic casts. A significant increase in surface roughness may produce rougher casts, resulting in rougher tissue surfaces for denture and cast restorations. Autoclave sterilization of vinyl polysiloxane elastomeric impressions for 5 minutes at 134°C at 20 psi may be considered an effective method over chemical disinfection and microwave sterilization, because chemical disinfection does

  16. Autoclavable physically-crosslinked chitosan cryogel as a wound dressing.

    Science.gov (United States)

    Takei, Takayuki; Danjo, So; Sakoguchi, Shogo; Tanaka, Sadao; Yoshinaga, Takuma; Nishimata, Hiroto; Yoshida, Masahiro

    2018-04-01

    Moist wounds were known to heal more rapidly than dry wounds. Hydrogel wound dressings were suitable for the moist wound healing because of their hyperhydrous structure. Chitosan was a strong candidate as a base material for hydrogel wound dressings because the polymer had excellent biological properties that promoted wound healing. We previously developed physically-crosslinked chitosan cryogels, which were prepared solely by freeze-thawing of a chitosan-gluconic acid conjugate (CG) aqueous solution, for wound treatment. The CG cryogels were disinfected by immersing in 70% ethanol before applying to wounds in our previous study. In the present study, we examined the influence of autoclave sterilization (121°C, 20 min) on the characteristics of CG cryogel because complete sterilization was one of the fundamental requirements for medical devices. We found that optimum value of gluconic acid content of CG, defined as the number of the incorporated gluconic acid units per 100 glucosamine units of chitosan, was 11 for autoclaving. An increased crosslinking level of CG cryogel on autoclaving enhanced resistance of the gels to enzymatic degradation. Furthermore, the autoclaved CG cryogels retained favorable biological properties of the pre-autoclaved CG cryogels in that they showed the same hemostatic activity and efficacy in repairing full-thickness skin wounds as the pre-autoclaved CG cryogels. These results showed the great potential of autoclavable CG cryogels as a practical wound dressing. Copyright © 2017 The Society for Biotechnology, Japan. Published by Elsevier B.V. All rights reserved.

  17. Autoclave Testing on Zirconium Alloy Materials

    International Nuclear Information System (INIS)

    Hoffmann, Petra-Britt; Sell, Hans-Juergen; Garzarolli, Friedrich

    2012-09-01

    The corrosion of Zirconium components like fuel rod claddings and spacer grids is limiting lifetime and duty of these components. In Pressurized and Boiling Water Reactors (PWR and BWR), different corrosion phenomena are of interest. Although in-pile experience is the final proof for a material development, significant experience was gained by autoclave tests, trying to simulate in-pile conditions but reducing time for return of experience by increased temperatures. For PWR application, the uniform corrosion is studied in water at up to 370 deg. C and in high pressure steam at 400 deg. C, and for BWR, the nodular corrosion is studied in high pressure steam at 500-520 deg. C. Particular attention has to be given to the corrosion media, because oxidative traces in the water can significantly affect the corrosion response. An extensive air removal is thus important for all corrosion tests. This links to the different water chemistry conditions that have been investigated as separate effects otherwise difficult to separate under in-pile conditions. Uniform corrosion in 350 deg. C water is usually a cyclic process with repeated rate transitions. In addition, at high exposure times an acceleration of corrosion can occur, e.g. for Zr-Sn alloys with a high Sn content. In 400 deg. C steam, corrosion rate decreases somewhat with increasing time. Uniform corrosion rate of Zr alloys depends on their Sn- and Fe+Cr contents as well as on their annealing parameters with a similar trend as in PWR and on their yield strength, however with an opposite trend compared to BWR conditions. Nodular corrosion of BWR alloys depends on the annealing parameter with a similar trend as in PWR and out-of-reactor also significantly on the Fe+Cr content. The hydrogen pickup fraction (HPUF) depends largely on details of the water chemistry and can particularly depend on autoclave degassing and probably also on autoclave contaminations. Thus any HPUF value from out-of- pile corrosion tests is only

  18. Validation of the efficacy of a solar-thermal powered autoclave system for off-grid medical instrument wet sterilization.

    Science.gov (United States)

    Kaseman, Tremayne; Boubour, Jean; Schuler, Douglas A

    2012-10-01

    This work describes the efficacy of a solar-thermal powered autoclave used for the wet sterilization of medical instruments in off-grid settings where electrical power is not readily available. Twenty-seven trials of the solar-thermal powered system were run using an unmodified non-electric autoclave loaded with a simulated bundle of medical instruments and biological test agents. Results showed that in 100% of the trials the autoclave achieved temperatures in excess of 121°C for 30 minutes, indicator tape displayed visible reactions to steam sterilization, and biological tests showed that microbial agents had been eliminated, in compliance with the Centers for Disease Control and Prevention requirements for efficacious wet sterilization.

  19. Anaerobic digestion of autoclaved and untreated food waste

    International Nuclear Information System (INIS)

    Tampio, Elina; Ervasti, Satu; Paavola, Teija; Heaven, Sonia; Banks, Charles; Rintala, Jukka

    2014-01-01

    Highlights: • Autoclaving decreased the formation of NH4-N and H 2 S during food waste digestion. • Stable digestion was achieved with untreated and autoclaved FW at OLR 6 kg VS/m 3 day. • Use of acclimated inoculum allowed very rapid increases in OLR. • Highest CH 4 yields were observed at OLR 3 kg VS/m 3 day with untreated FW. • Autoclaved FW produced highest CH 4 yields during OLR 4 kgVS/m 3 day. - Abstract: Anaerobic digestion of autoclaved (160 °C, 6.2 bar) and untreated source segregated food waste (FW) was compared over 473 days in semi-continuously fed mesophilic reactors with trace elements supplementation, at organic loading rates (OLRs) of 2, 3, 4 and 6 kg volatile solids (VS)/m 3 d. Methane yields at all OLR were 5–10% higher for untreated FW (maximum 0.483 ± 0.013 m 3 CH 4 /kg VS at 3 kg VS/m 3 d) than autoclaved FW (maximum 0.439 ± 0.020 m 3 CH 4 /kg VS at 4 kg VS/m 3 d). The residual methane potential of both digestates at all OLRs was less than 0.110 m 3 CH 4 /kg VS, indicating efficient methanation in all cases. Use of acclimated inoculum allowed very rapid increases in OLR. Reactors fed on autoclaved FW showed lower ammonium and hydrogen sulphide concentrations, probably due to reduced protein hydrolysis as a result of formation of Maillard compounds. In the current study this reduced biodegradability appears to outweigh any benefit due to thermal hydrolysis of ligno-cellulosic components

  20. Anaerobic digestion of autoclaved and untreated food waste

    Energy Technology Data Exchange (ETDEWEB)

    Tampio, Elina, E-mail: elina.tampio@mtt.fi [Bioenergy and Environment, MTT Agrifood Research Finland, FI-31600 Jokioinen (Finland); Ervasti, Satu; Paavola, Teija [Bioenergy and Environment, MTT Agrifood Research Finland, FI-31600 Jokioinen (Finland); Heaven, Sonia; Banks, Charles [University of Southampton, Faculty of Engineering and the Environment, Southampton SO17 1BJ (United Kingdom); Rintala, Jukka [Bioenergy and Environment, MTT Agrifood Research Finland, FI-31600 Jokioinen (Finland)

    2014-02-15

    Highlights: • Autoclaving decreased the formation of NH4-N and H{sub 2}S during food waste digestion. • Stable digestion was achieved with untreated and autoclaved FW at OLR 6 kg VS/m{sup 3}day. • Use of acclimated inoculum allowed very rapid increases in OLR. • Highest CH{sub 4} yields were observed at OLR 3 kg VS/m{sup 3}day with untreated FW. • Autoclaved FW produced highest CH{sub 4} yields during OLR 4 kgVS/m{sup 3}day. - Abstract: Anaerobic digestion of autoclaved (160 °C, 6.2 bar) and untreated source segregated food waste (FW) was compared over 473 days in semi-continuously fed mesophilic reactors with trace elements supplementation, at organic loading rates (OLRs) of 2, 3, 4 and 6 kg volatile solids (VS)/m{sup 3} d. Methane yields at all OLR were 5–10% higher for untreated FW (maximum 0.483 ± 0.013 m{sup 3} CH{sub 4}/kg VS at 3 kg VS/m{sup 3} d) than autoclaved FW (maximum 0.439 ± 0.020 m{sup 3} CH{sub 4}/kg VS at 4 kg VS/m{sup 3} d). The residual methane potential of both digestates at all OLRs was less than 0.110 m{sup 3} CH{sub 4}/kg VS, indicating efficient methanation in all cases. Use of acclimated inoculum allowed very rapid increases in OLR. Reactors fed on autoclaved FW showed lower ammonium and hydrogen sulphide concentrations, probably due to reduced protein hydrolysis as a result of formation of Maillard compounds. In the current study this reduced biodegradability appears to outweigh any benefit due to thermal hydrolysis of ligno-cellulosic components.

  1. Autoclaved lightweight aerated concrete. ; Manufacture/performance/application. Keiryo kiho concrete. ; Sono seiho kino yoto

    Energy Technology Data Exchange (ETDEWEB)

    Isome, Y. (Asahi Chemical Industry Co. Ltd., Tokyo (Japan))

    1993-10-20

    This paper reviews the manufacturing process, performance, and application of autoclaved lightweight aerated concrete (ALC). ALC is produced by a two-step process composed of molding and autoclaving, using quartz, lime, portland cement, and small quantities of aluminum as raw materials. In the molding step, aluminum reacts with alkali to generate hydrogen gas, thus forming air pores in the slurry. On the other hand, calcium silicate hydrates are produced by the reaction of lime and portland cement with water, resulting in formation of voids in the intergranular spaces vacated by the reacting water. In the autoclaving step, tobermorite (crystalline calcium silicate hydrates) is formed by the reaction of quartz and calcium silicate hydrates under high temperature and high pressure steam, and the intergranular voids are reduced to micropores in size as a result of the hydrothermal reaction. The air-pore and micropore structure adds unique physical properties to the ALC, such as fire resistance, heat insulation, lightness and strength. ALC is widely used as a useful material for homes and multistory buildings. 10 refs., 10 figs., 1 tab.

  2. Incineration or autoclave? A comparative study in isfahan hospitals waste management system (2010).

    Science.gov (United States)

    Ferdowsi, Ali; Ferdosi, Masoud; Mehrani, Mohammd Javad

    2013-03-01

    Medical wastes are among hazardous wastes and their disposal requires special methods prior to landfilling. Medical wastes are divided into infected and non-infected wastes and the infected wastes require treatment. Incineration is one of the oldest methods for treatment of medical wastes, but their usage have faced wide objections due to emission of hazardous gases such as CO2 and CO as well as Carcinogenic gases such as Dioxins and Furans which are generated as a result of incomplete combustion of compositions like PVCs. Autoclave is one the newest methods of medical wastes treatment which works based on wet disinfection. The statistical population in this descriptive, comparative study includes hospitals located in Isfahan city and the sample hospitals were selected randomly. To environmentally evaluate the Autoclave method, TST (time, steam, temperature) and Spore tests were used. Also, samples were made from incinerator's stack gases and their analyses results were compared with WHO standards. TST and spore tests results were negative in all cases indicating the success of treatment process. The comparison of incinerator's stack gases with WHO standards showed the high concentration of CO in some samples indicating the incomplete combustion. Also, the incineration efficiency in some cases was less than 99.5 percent, which is the efficiency criterion according to the administrative regulations of wastes management law of Iran. No needle stick was observed in Autoclave method during the compaction of bags containing wastes, and the handlers were facing no danger in this respect. The comparison of costs indicated that despite higher capital investment for purchasing autoclave, its current costs (e.g. maintenance, etc) are much less than the incineration method. Totally, due to inappropriate operation of incinerators and lack of air pollution control devices, the use of incinerators doesn't seem rational anymore. Yet, despite the inefficiency of autoclaves in

  3. Incineration or Autoclave? A Comparative Study in Isfahan Hospitals Waste Management System (2010)

    Science.gov (United States)

    Ferdowsi, Ali; Ferdosi, Masoud; Mehrani, Mohammd Javad

    2013-01-01

    Introduction: Medical wastes are among hazardous wastes and their disposal requires special methods prior to landfilling. Medical wastes are divided into infected and non-infected wastes and the infected wastes require treatment. Incineration is one of the oldest methods for treatment of medical wastes, but their usage have faced wide objections due to emission of hazardous gases such as CO2 and CO as well as Carcinogenic gases such as Dioxins and Furans which are generated as a result of incomplete combustion of compositions like PVCs. Autoclave is one the newest methods of medical wastes treatment which works based on wet disinfection. Methods: The statistical population in this descriptive, comparative study includes hospitals located in Isfahan city and the sample hospitals were selected randomly. To environmentally evaluate the Autoclave method, TST (time, steam, temperature) and Spore tests were used. Also, samples were made from incinerator’s stack gases and their analyses results were compared with WHO standards. Findings: TST and spore tests results were negative in all cases indicating the success of treatment process. The comparison of incinerator’s stack gases with WHO standards showed the high concentration of CO in some samples indicating the incomplete combustion. Also, the incineration efficiency in some cases was less than 99.5 percent, which is the efficiency criterion according to the administrative regulations of wastes management law of Iran. No needle stick was observed in Autoclave method during the compaction of bags containing wastes, and the handlers were facing no danger in this respect. The comparison of costs indicated that despite higher capital investment for purchasing autoclave, its current costs (e.g. maintenance, etc) are much less than the incineration method. Discussion: Totally, due to inappropriate operation of incinerators and lack of air pollution control devices, the use of incinerators doesn’t seem rational anymore

  4. Direct Synthesis of Fe3C-Functionalized Graphene by High Temperature Autoclave Pyrolysis for Oxygen Reduction

    DEFF Research Database (Denmark)

    Hu, Yang; Jensen, Jens Oluf; Zhang, Wei

    2014-01-01

    We present a novel approach to direct fabrication of few-layer graphene sheets with encapsulated Fe3C nanoparticles from pyrolysis of volatile non-graphitic precursors without any substrate. This one-step autoclave approach is facile and potentially scalable for production. Tested as an electroca...

  5. Corrosion behaviour of zirconium alloys in the autoclaves of Embalse nuclear power plant

    International Nuclear Information System (INIS)

    Bordoni, Roberto A.; Olmedo, Ana M.; Villegas, Marina; Miyagusuku, Marcela; Maroto, Alberto J. G.; Sainz, Ricardo A.; Fernandez, Alberto N.; Allemandi, Walter D.

    1999-01-01

    The corrosion behaviour of zirconium alloys coupons attached to the holders of the autoclaves located out of core in the primary circuit of Embalse nuclear power plant is described. The Zr-2.5 Nb coupons of the autoclaves at the higher temperature (305 C degrees) and the Zry-4 coupons of the autoclaves at 265 and 305 C degrees installed in 1988 had a normal corrosion behaviour, after 3500 of full power days. While, the Zr-2.5 Nb coupons, at 265 C degrees, showed the presence of white oxide nuclei and a weight gain indicating an abnormal corrosion behaviour which might be attributed to the material microstructure. Complementary tests, made in the period September 1991-April 1993, showed that the abnormal corrosion behaviour observed for the Canadian coupons installed in 1983 was due to a surface contamination of the Zry-4 coupons and due to the microstructure of the Zr-2.5 Nb coupons. The normal corrosion behaviour for both alloys installed in 1986, showed that the resin ingress to the primary circuit that occurred in 1988, do not affect the performance of these materials. (author)

  6. BALU: Largest autoclave research facility in the world

    Directory of Open Access Journals (Sweden)

    Hakan Ucan

    2016-03-01

    Full Text Available Among the large-scale facilities operated at the Center for Lightweight-Production-Technology of the German Aerospace Center in Stade BALU is the world's largest research autoclave. With a loading length of 20m and a loading diameter of 5.8 m the main objective of the facility is the optimization of the curing process operated by components made of carbon fiber on an industrial scale. For this reason, a novel dynamic autoclaving control has been developed that is characterized by peripheral devices to expend the performance of the facility for differential applications, by sensing systems to detect the component state throughout the curing process and by a feedback system, which is capable to intervene into the running autoclave process.

  7. Color stability of shade guides after autoclave sterilization.

    Science.gov (United States)

    Schmeling, Max; Sartori, Neimar; Monteiro, Sylvio; Baratieri, Luiz

    2014-01-01

    This study evaluated the influence of 120 autoclave sterilization cycles on the color stability of two commercial shade guides (Vita Classical and Vita System 3D-Master). The specimens were evaluated by spectrophotometer before and after the sterilization cycles. The color was described using the three-dimensional CIELab system. The statistical analysis was performed in three chromaticity coordinates, before and after sterilization cycles, using the paired samples t test. All specimens became darker after autoclave sterilization cycles. However, specimens of Vita Classical became redder, while those of the Vita System 3D-Master became more yellow. Repeated cycles of autoclave sterilization caused statistically significant changes in the color coordinates of the two shade guides. However, these differences are considered clinically acceptable.

  8. Long Out-time, Out-of-Autoclave Cure Composites, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — As the size of composite parts exceed that of even the largest autoclaves, new out-of-autoclave processes and materials are necessary to achieve the same level of...

  9. Long Out-time, Out-of-Autoclave Cure Composites, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — As the size of composite parts exceed that of even the largest autoclaves, new out-of-autoclave processes and materials are necessary to achieve the same level of...

  10. [Influence of autoclave sterilization on dimensional stability and detail reproduction of 5 additional silicone impression materials].

    Science.gov (United States)

    Xu, Tong-kai; Sun, Zhi-hui; Jiang, Yong

    2012-03-01

    To evaluate the dimensional stability and detail reproduction of five additional silicone impression materials after autoclave sterilization. Impressions were made on the ISO 4823 standard mold containing several marking lines, in five kinds of additional silicone. All the impressions were sterilized by high temperature and pressure (135 °C, 212.8 kPa) for 25 min. Linear measurements of pre-sterilization and post-sterilization were made with a measuring microscope. Statistical analysis utilized single-factor analysis with pair-wise comparison of mean values when appropriate. Hypothesis testing was conducted at alpha = 0.05. No significant difference was found between the pre-sterilization and post-sterilization conditions for all locations, and all the absolute valuse of linear rate of change less than 8%. All the sterilization by the autoclave did not affect the surfuce detail reproduction of the 5 impression materials. The dimensional stability and detail reproduction of the five additional silicone impression materials in the study was unaffected by autoclave sterilization.

  11. Characteristics of Chemical and Functional Properties of Modified Cassava Flour (Manihot esculenta) by Autoclaving-Cooling Cycles Method

    Science.gov (United States)

    Cecep Erwan Andriansyah, Raden; Rahman, Taufik; Herminiati, Ainia; Rahman, Nurhaidar; Luthfiyanti, Rohmah

    2017-12-01

    The modified cassava flour can be made using the method of the autoclaving cooling cycle (AAC). The stability of the warming can be seen from the decreasing value of breakdown viscosity, while the stability of the stirring process can be seen by the decreasing value of setback viscosity. The stages of research include: (1) the making of cassava flour, (2) the making of modified cassava flour by the method of treatment of ACC with a variety of flour concentration and autoclaving time, (3) chemical analysis of the moisture, ash, fat, protein, carbohydrate; The functional properties of the pasting characteristics to the initial temperature of the pasting, peak viscosity, hot paste viscosity, breakdown viscosity, cold paste viscosity and setback viscosity. The result shows that cassava flour modified by treatment of flour concentration 16% and autoclaving time 41 minutes having pasting code and pasting viscosity which is resistant to high temperature. Flour with this character is flour that is expected to maintain the texture of processed products with a paste form that remains stable. Utilization of modified cassava flour by the ACC method can be applied to the pasting product such as noodle and spaghetti, hoping to support for food diversification program to reduce dependence on wheat flour in Indonesia.

  12. [The influence of autoclave sterilization on surface characteristics and cyclic fatigue resistance of 3 nickel-titanium rotary instruments].

    Science.gov (United States)

    Li, Xiang-fen; Zheng, Ping; Xu, Li; Su, Qin

    2015-12-01

    To investigate the effects of autoclave sterilization on surface characteristics and cyclic fatigue resistance of 3 types of nickel-titanium rotary instruments (K3, Mtwo, ProTaper). Three brands of NiTi rotary endodontic instruments of the same size (tip diameter 0.25 mm and constant 0.06 taper) were selected: K3, Mtwo and Protaper (F2). 24 instruments for each brand were used to evaluate the effects of autoclave sterilization on inner character in the as-received condition and after subjection to 0, 1, 5, and 10 sterilization cycles (6 for each group). Time to fracture (TtF) from the start of the test to the moment of file breakage and the length of the fractured fragment were recorded. Means and standard deviations of TtF and fragment length were calculated. The data was analyzed with SPSS13.0 software package. Another 12 NiTi rotary instruments for each brand were used, 6 subjected to 10 autoclave sterilization cycles and the other as control. Scanning electron microscope was used to observe the changes in surface topography and inner character. For cyclic fatigue resistance, when sterilization was not performed, K3 showed the highest value of TtF means and ProTaper the lowest. The differences between each brand were statistically significant (Pinstruments were intensified greatly after 10 cycles of sterilization. Cycle fatigue resistance is different among instruments of different brands. Autoclave sterilization may increase fatigue resistance of the 3 brands. Autoclave sterilization may increase the surface roughness and inner defects in cross section.

  13. Shear reinforced beams in autoclaved aerated concrete

    DEFF Research Database (Denmark)

    Cornelius, Thomas

    2010-01-01

    Shear behaviour in concrete materials is very well documented, for normal density concrete materials. In this paper results of various tests on low density concrete materials like aerated autoclaved concrete (in the following denoted aircrete) will be presented and analyzed for different combinat....... Codes for designing prefabricated reinforced components of aircrete structures have adopted these recently developed approaches.......Shear behaviour in concrete materials is very well documented, for normal density concrete materials. In this paper results of various tests on low density concrete materials like aerated autoclaved concrete (in the following denoted aircrete) will be presented and analyzed for different...

  14. Alkaline autoclave leaching of refractory uranium-thorium minerals

    International Nuclear Information System (INIS)

    Milani, S. A.; Sam, S.

    2011-01-01

    This paper deals with the study of an innovative method for processing the Oman placer ores by alkaline leaching in ball mill autoclaves, where grinding and leaching of the refractory minerals take place simultaneously. This was followed by the selective separation of thorium and uranium from lanthanides by autoclave leaching of the hydroxide cake with ammonium carbonate-bicarbonate solutions. The introduced method is based on the fact that thorium and uranium form soluble carbonate complexes with ammonium carbonate, while lanthanides form sparingly soluble double carbonates. It was found that a complete alkaline leaching of Oman placer ores (98.0 P ercent ) was attained at 150 and 175 d egree C within 2.5 and 2h, respectively. Oman placer ores leaching was intensified and accelerated in a ball mill autoclaves as a result of the grinding action of steel balls, removal of the hydroxide layer covering ores grains and the continuous contact of fresh ore grains with alkaline solution. The study of selective carbonate processing of hydroxide cake with ammonium carbonate-bicarbonate solutions on autoclave under pressure revealed that the complete thorium recovery (97.5 P ercent ) with uranium recovery (90.8 P ercent ) and their separation from the lanthanides were attained at 70-80 d egree C during l-2h. The extraction of lanthanides in carbonate solution was low and did not exceed 4.6 P ercent .

  15. Out-of-autoclave manufacturing of GLARE panels using resistance heating

    NARCIS (Netherlands)

    Muller, B.; Palardy, G.; Teixeira De Freitas, S.; Sinke, J.

    2017-01-01

    Autoclave manufacturing of fibre metal laminates, such as GLARE, is an expensive process.Therefore, there is an increasing interest to find cost effective out-of-autoclave manufacturing processes without diminishing the laminate quality. The aim of this study is to

  16. Study of {sup 24}Na activity in concrete using 20-MeV proton beam on Cu

    Energy Technology Data Exchange (ETDEWEB)

    Oranj, Leila Mokhtanri; Jung, Nam Suk; Lee, Arim; Heo, Tae Min; Bakhtian, Mahdi; Lee, Hee Seock [POSTECH, Pohang (Korea, Republic of)

    2017-04-15

    The number of medical cyclotrons capable of accelerating protons to about 20 MeV is increasing in Korea. In such facilities, various radionuclides could be induced in shielding materials like concrete from secondary neutrons which Causes problems from the view point of radiation safety. Among these radionuclides, gamma-ray from {sup 24}Na (Tz1/2 = 15 h) is the most important origin of radiation exposure. {sup 24}Na could be produced from secondary neutrons on Na, Al and Mg component which exist in the concrete. {sup 24} Na Could be produced from thermal neutrons on Na and fast neutron with energy lower than 20 MeV on Al and Mg. Due to interaction of 20 MeV protons on Cu target, secondary neutrons with the energy of less than 20 MeV were produced. therefore, among the concrete components, Na, Al and Mg are only corespondent to produce {sup 24}Na. In this work, {sup 24}Na activity induced in concrete and chemical reagents of concrete (NaHCO{sub 3}, Al{sub 2}O{sub 3} and MgO) were measured. To produce neutrons, Cu target was irradiated by 20 MeV protons. Measured data were compared with results of simulations by FLUKA and MARS as well as earlier works and theocratical data. In the case of Mg and Al chemical reagents, FLUKA code overestimates our measurements by approximately four times, while, for Na sample, FLUKA underestimates the experimental data by almost 0.5. Data from FLUKA and measurement for the concrete are consistent. Calculation from TALYS for Mg overestimates the measured data by a factor of 2.5.

  17. Treatment of clinical solid waste using a steam autoclave as a possible alternative technology to incineration.

    Science.gov (United States)

    Hossain, Md Sohrab; Balakrishnan, Venugopal; Rahman, Nik Norulaini Nik Ab; Sarker, Md Zaidul Islam; Kadir, Mohd Omar Ab

    2012-03-01

    A steam autoclave was used to sterilize bacteria in clinical solid waste in order to determine an alternative to incineration technology in clinical solid waste management. The influence of contact time (0, 5, 15, 30 and 60 min) and temperature (111 °C, 121 °C and 131 °C) at automated saturated steam pressure was investigated. Results showed that with increasing contact time and temperature, the number of surviving bacteria decreased. The optimum experimental conditions as measured by degree of inactivation of bacteria were 121 °C for 15 minutes (min) for Gram negative bacteria, 121 °C and 131 °C for 60 and 30 min for Gram positive bacteria, respectively. The re-growth of bacteria in sterilized waste was also evaluated in the present study. It was found that bacterial re-growth started two days after the inactivation. The present study recommends that the steam autoclave cannot be considered as an alternative technology to incineration in clinical solid waste management.

  18. Treatment of Clinical Solid Waste Using a Steam Autoclave as a Possible Alternative Technology to Incineration

    Science.gov (United States)

    Hossain, Md. Sohrab; Balakrishnan, Venugopal; Rahman, Nik Norulaini Nik Ab; Sarker, Md. Zaidul Islam; Kadir, Mohd Omar Ab

    2012-01-01

    A steam autoclave was used to sterilize bacteria in clinical solid waste in order to determine an alternative to incineration technology in clinical solid waste management. The influence of contact time (0, 5, 15, 30 and 60 min) and temperature (111 °C, 121 °C and 131 °C) at automated saturated steam pressure was investigated. Results showed that with increasing contact time and temperature, the number of surviving bacteria decreased. The optimum experimental conditions as measured by degree of inactivation of bacteria were 121 °C for 15 minutes (min) for Gram negative bacteria, 121 °C and 131 °C for 60 and 30 min for Gram positive bacteria, respectively. The re-growth of bacteria in sterilized waste was also evaluated in the present study. It was found that bacterial re-growth started two days after the inactivation. The present study recommends that the steam autoclave cannot be considered as an alternative technology to incineration in clinical solid waste management. PMID:22690168

  19. Effect of Autoclave Cycles on Surface Characteristics of S-File Evaluated by Scanning Electron Microscopy.

    Science.gov (United States)

    Razavian, Hamid; Iranmanesh, Pedram; Mojtahedi, Hamid; Nazeri, Rahman

    2016-01-01

    Presence of surface defects in endodontic instruments can lead to unwanted complications such as instrument fracture and incomplete preparation of the canal. The current study was conducted to evaluate the effect of autoclave cycles on surface characteristics of S-File by scanning electron microscopy (SEM). In this experimental study, 17 brand new S-Files (#30) were used. The surface characteristics of the files were examined in four steps (without autoclave, 1 autoclave cycle, 5 autoclave cycles and 10 autoclave cycles) by SEM under 200× and 1000× magnifications. Data were analyzed using the SPSS software and the paired sample t-test, independent sample t-test and multifactorial repeated measures ANOVA. The level of significance was set at 0.05. New files had debris and pitting on their surfaces. When the autoclave cycles were increased, the mean of surface roughness also increased at both magnifications (Pautoclave increased the surface roughness of the files and this had was directly related to the number of autoclave cycles.

  20. Generating Autoclave-Level Mechanical Properties with Out-of-Autoclave Thermoplastic Placement of Large Composite Aerospace Structures, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Out-of-autoclave thermoplastic tape/tow placement (TP-ATP) is nearing commercialization but suffers a moderate gap in mechanical properties compared with laminates...

  1. OPTIMAL CONTROL OF AUTOCLAVE START MODE IN THE PRODUCTION OF NITRIC ACID

    OpenAIRE

    Ладієва, Леся Ростиславівна; Ширма, А. В.

    2015-01-01

    The algorithm of optimal control of autoclave start mode in the production of nitric acid is proposed. By optimality criterion is selected minimum time-autoclave at preset mode with the restriction on the concentration of nitric acid. End time start mode is entered on the terminal part of the cost function. The method of penalties and a gradient procedure is used to solve the problem. The applied algorithm is allowed to bring an autoclave at a given technological regime.Keywords: production o...

  2. Circulating progesterone concentrations in nonlactating Holstein cows during reuse of intravaginal progesterone implants sanitized by autoclave or chemical disinfection.

    Science.gov (United States)

    Melo, L F; Monteiro, P L J; Oliveira, L H; Guardieiro, M M; Drum, J N; Wiltbank, M C; Sartori, R

    2018-04-01

    The aim of this study was to compare plasma progesterone (P4) concentrations in nonlactating, multiparous Holstein cows (n = 24) treated with 2 types of intravaginal implants containing either 1.0 or 1.9 g of P4 either at the first use or during reuse of the implants after sanitizing the implant by autoclave or chemical disinfection. In a completely randomized design with a 2 × 3 factorial arrangement and 2 replicates, every cow underwent 2 of 6 treatments. Two sources of P4 [controlled internal drug release (1.9 g of P4) from Zoetis (São Paulo, Brazil), and Sincrogest (1.0 g of P4) from Ourofino (Cravinhos, Brazil)] and 3 types of processing, new (N), reused after autoclave (RA), and reused after chemical disinfection (RC), were used. After inducing luteolysis to avoid endogenous circulating P4, the cows were randomized in 1 of 6 treatments (1.9 g of N, 1.9 g of RA, 1.9 g of RC, 1.0 g of N, 1.0 g of RA, and 1.0 g RC). Cows were treated with the implants for 8 d and during this period blood samples were collected at 0, 2, 12, 24, 48, 72, 96, 120, 144, 168, and 192 h. Statistical analyses were performed using Proc-Mixed and the mean ± standard error of the mean P4 concentrations were calculated using the Proc-Means procedures of SAS 9.4 (SAS Institute Inc., Cary, NC). No interaction between treatments was observed. Comparing types of implant, average P4 concentrations during treatments were greater for 1.9 g than 1.0 g (1.46 vs. 1.14 ± 0.04 ng/mL). When types of processing were compared, average P4 concentrations did not differ between autoclaved and new inserts (1.46 vs. 1.37 ± 0.05 ng/mL; respectively), but both were greater than chemically disinfected implants (1.09 ± 0.04 ng/mL). Within 1.9-g P4 inserts, P4 concentrations from autoclaved implants were greater than new, which were greater than chemically disinfected (1.67 ± 0.06 vs. 1.49 ± 0.07 vs. 1.21 ± 0.05 ng/mL; respectively). For 1.0-g P4 implants, P4 concentrations from autoclaved did not differ

  3. ETUDE DU COMPORTEMENT MECANIQUE DU BETON CELLULAIRE AUTOCLAVE PRODUIT EN ALGERIE

    Directory of Open Access Journals (Sweden)

    R BELOUETTAR

    2002-12-01

    Full Text Available Ce travail présente une étude expérimentale du comportement mécanique du béton cellulaire autoclavé. L’étude est portée essentiellement sur une série d’essais mécaniques en compression quasistatique à différentes vitesses de déformation variables entre 10-4 s-1 et 10 s-1 et à deux états différents (état sec et état saturé d’eau. En général, l’augmentation de la vitesse de déformation donne une augmentation de la contrainte critique du béton cellulaire autoclavé. Le béton cellulaire autoclavé présente une sensibilité à la vitesse de déformation positive. La valeur du module d’élasticité est proche de la valeur standard (1.5 GPa pour un béton cellulaire autoclavé de masse volumique égale à 500-550 kg/m3.

  4. Toxic anterior segment syndrome caused by autoclave reservoir wall biofilms and their residual toxins.

    Science.gov (United States)

    Sorenson, Andrew L; Sorenson, Robert L; Evans, David J

    2016-11-01

    To identify etiology of toxic anterior segment syndrome (TASS) after uneventful phacoemulsification. EyeMD Laser and Surgery Center, Oakland, California. Retrospective case series. Patient charts with TASS were reviewed. Reservoirs of 2 autoclaves associated with these cases were cultured for bacterial contamination. Cultures were performed on 23 other autoclave reservoirs at surgery centers in the local area. The main outcome measures were the incidence of TASS and prevalence of bacterial biofilm contamination of autoclave reservoirs. From 2010 to 2013, 11 935 consecutive cataract surgeries were performed at 1 center by multiple surgeons with no reported TASS. Between January 1, 2014, and January 15, 2015, 10 cases of TASS occurred out of 3003 cataract surgeries; these patients' charts were reviewed. Cultures of 2 Statim autoclave reservoir walls grew Bacillus species, Williamsia species, Mycobacterium mucogenicum, and Candida parapsilosis. Scanning electron microscopy of reservoir wall sections showed prominent biofilm. The 2 autoclaves were replaced in January 2015. Subsequently, 2875 cataract surgeries were performed with no reported TASS (P autoclaves were also contaminated with bacterial biofilms. Toxic anterior segment syndrome was strongly associated with bacterial biofilm contamination of autoclave reservoirs. An etiological mechanism might involve transport of heat-stable bacterial cell antigens in the steam with deposition on surgical instrumentation. Data suggest widespread prevalence of bacterial biofilms on fluid-reservoir walls, despite adherence to manufacturer guidelines for cleaning and maintenance. Prevention or elimination of autoclave fluid-reservoir biofilms might reduce the risk for postoperative TASS. None of the authors has a financial or proprietary interest in any material or method mentioned. Copyright © 2016 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  5. Non-autoclaved aerated concrete with mineral additives

    Science.gov (United States)

    Il'ina, L. V.; Rakov, M. A.

    2016-01-01

    We investigated the effect of joint grinding of Portland cement clinker, silica and carbonate components and mineral additives to specific surface of 280 - 300 m2/kg on the properties (strength, average density and thermal conductivity) of non-autoclaved aerated concrete, and the porosity of the hardened cement paste produced from Portland cement clinker with mineral additives. The joint grinding of the Portland cement clinker with silica and carbonate components and mineral additives reduces the energy consumption of non-autoclaved aerated concrete production. The efficiency of mineral additives (diopside, wollastonite) is due to the closeness the composition, the type of chemical bonds, physical and chemical characteristics (specific enthalpy of formation, specific entropy) to anhydrous clinker minerals and their hydration products. Considering the influence of these additions on hydration of clinker minerals and formation of hardened cement paste structure, dispersed wollastonite and diopside should be used as mineral additives. The hardness and, consequently, the elastic modulus of diopside are higher than that of hardened cement paste. As a result, there is a redistribution of stresses in the hardened cement paste interporous partitions and hardening, both the partitions and aerated concrete on the whole. The mineral additives introduction allowed to obtain the non-autoclaved aerated concrete with average density 580 kg/m3, compressive strength of 3.3 MPa and thermal conductivity of 0.131 W/(m.°C).

  6. Fourier transform infrared (FTIR) fiber optic monitoring of composites during cure in an autoclave

    Science.gov (United States)

    Druy, Mark A.; Elandjian, Lucy; Stevenson, William A.; Driver, Richard D.; Leskowitz, Garett M.

    1990-01-01

    Real-time in situ monitoring of the chemical states of epoxy resins was investigated during cure in an autoclave using infrared evanescent spectroscopy. Fiber evanescent sensors were developed which may be sandwiched between the plies of the prepreg sample. A short length of sapphire fiber was used as the sensor cell portion of the fiber probe. Heavy metal fluoride glass optical fiber cables were designed for connecting the FTIR spectrometer to the sensor fiber within the autoclave. The sapphire fibers have outstanding mechanical thermal properties which should permit their use as an embedded link in all thermoset composites. The system is capable of operation at a temperature of 250 C for periods up to 8 hours without major changes to the fiber transmission. A discussion of the selection of suitable sensor fibers, the construction of a fiber-optic interface, and the interpretation of in situ infrared spectra of the curing process is presented.

  7. Moisture conditions of modern structures made of autoclaved aerated concrete in operation period

    OpenAIRE

    P.S. Zyryanov; G.I. Grinfeld; Р.A. Morozov; I.A. Sogomonyan

    2011-01-01

    In St.-Petersburg and area six organizations making cellular concrete of autoclave hardening operate. At all enterprises the cellular concrete is made by the gas way of pore development by molding technology. The molding technology in practice means that the mass humidity of concrete on an exit from autoclaves will be at level of 35-45 % (great values of humidity correspond to smaller density). The similar situation is observed in other regions: more than 80 % of all autoclave cellular concre...

  8. Autoclave corrosion of zircaloy-4 cladding samples in LiOH solutions

    International Nuclear Information System (INIS)

    Hermann, A.

    2010-03-01

    In reactor operation, pH of the cooling water is adjusted by addition of alkaline hydroxides, and LiOH has been found to be the most suitable one. The addition of LiOH above a certain concentration level (depending on temperature) increases the corrosion rate of zirconium and its alloys. Hydrogen pick-up by the metal is also increased, and this effect is used to produce hydrided specimens for different investigations using the corrosion reaction. At the Paul Scherrer Institute several projects were accomplished to investigate the influence of hydrogen in Zircaloy cladding on its mechanical properties. In order to produce hydrided specimens for comparison and for adjusting new equipment, Zircaloy tubing samples were hydrogen charged by autoclave corrosion in lithiated water. Results of the corrosion experiments are outlined in this publication. Because of the great variety of possible experimental parameters these results are still of interest for the scientific community. Autoclave corrosion was accomplished in 0.2 M or 0.5 M LiOH solution at a constant temperature of 340 o C and a pressure of 160 bar. The corrosion rate increases from 84 mg/(dm 2 d) in 0.2 M LiOH to 153 mg/(dm 2 d) in 0.5 M LiOH. The hydrogen pick-up fraction in 0.5 M LiOH amounts to 80%. In 0.5 M LiOH, Zircaloy tubing samples can be charged with ∼ 500 ppm hydrogen in about 40 hours. In the corrosion experiments described in this report a homogeneous distribution of hydrides should be expected (except very high hydride concentrations) because no temperature gradient exists through the tubing wall. Hydrogen stringers are homogeneously distributed with circumferential orientation (stress-relieved tubing samples). (author)

  9. Autoclave and beta-amylolysis lead to reduced in vitro digestibility of starch.

    Science.gov (United States)

    Hickman, B Elliot; Janaswamy, Srinivas; Yao, Yuan

    2009-08-12

    In this study, a combination of autoclave and beta-amylolysis was used to modulate the digestibility of normal corn starch (NCS) and wheat starch (WS). The modification procedure comprised three cycles of autoclave at 35% moisture content and 121 degrees C, beta-amylolysis, and one additional cycle of autoclave. Starch materials were sampled at each stage and characterized. The fine structure of starch was determined using high-performance size-exclusion chromatography, the micromorphology of starch dispersion was imaged using cryo-SEM, the crystalline pattern was evaluated using wide-angle X-ray powder diffraction, and the digestibility was measured using Englyst assay. After beta-amylolysis, amylose was enriched (from 25.4 to 33.2% for NCS and from 27.5 to 32.8% for WS) and the branch density was increased (from 5.2 to 7.7% for NCS and from 5.3 to 7.9% for WS). Cryo-SEM images showed that the autoclave treatment led to the formation of a low-swelling, high-density gel network, whereas beta-amylolysis nearly demolished the network structure. The loss of A-type crystalline structure and the formation of B- and V-type structures resulted from autoclave, which suggests the formation of amylose-based ordered structure. Englyst assay indicated that, due to beta-amylolysis, the resistant starch (RS) content was increased to 30 from 11% of native NCS and to 23 from 9% of native WS. In contrast, autoclave showed only minor impact on RS levels. The increase of RS observed in this study is associated with enhanced branch density, which is different from the four types of RS commonly defined.

  10. Composite Cryotank Technologies and Development 2.4 and 5.5M out of Autoclave Tank Test Results

    Science.gov (United States)

    Jackson, Justin R.; Vickers, John; Fikes, John

    2015-01-01

    The Composite Cryotank Technologies and Demonstration (CCTD) project substantially matured composite, cryogenic propellant tank technology. The project involved the design, analysis, fabrication, and testing of large-scale (2.4-m-diameter precursor and 5.5-m-diameter) composite cryotanks. Design features included a one-piece wall design that minimized tank weight, a Y-joint that incorporated an engineered material to alleviate stress concentration under combined loading, and a fluted core cylindrical section that inherently allows for venting and purging. The tanks used out-of-autoclave (OoA) cured graphite/epoxy material and processes to enable large (up to 10-m-diameter) cryotank fabrication, and thin-ply prepreg to minimize hydrogen permeation through tank walls. Both tanks were fabricated at Boeing using automated fiber placement on breakdown tooling. A fluted core skirt that efficiently carried axial loads and enabled hydrogen purging was included on the 5.5-m-diameter tank. Ultrasonic inspection was performed, and a structural health monitoring system was installed to identify any impact damage during ground processing. The precursor and 5.5-m-diameter tanks were tested in custom test fixtures at the National Aeronautics and Space Administration Marshall Space Flight Center. The testing, which consisted of a sequence of pressure and thermal cycles using liquid hydrogen, was successfully concluded and obtained valuable structural, thermal, and permeation performance data. This technology can be applied to a variety of aircraft and spacecraft applications that would benefit from 30 to 40% weight savings and substantial cost savings compared to aluminum lithium tanks.

  11. Autoclaving practice in microbiology laboratories: report of a survey. The Public Health Laboratory Service Subcommittee on laboratory autoclaves.

    Science.gov (United States)

    1978-01-01

    The performance of autoclaves in 27 laboratories, operated in accordance with the normal routine of local practice, has been monitored using thermometric equipment. Sterilising performance was unsatisfactory on 10 of 62 occasions, and cooling was inadequate on 52 of 60 occasions. PMID:649767

  12. UV irradiation and autoclave treatment for elimination of contaminating DNA from laboratory consumables.

    Science.gov (United States)

    Gefrides, Lisa A; Powell, Mark C; Donley, Michael A; Kahn, Roger

    2010-02-01

    Laboratories employ various approaches to ensure that their consumables are free of DNA contamination. They may purchase pre-treated consumables, perform quality control checks prior to casework, and use in-house profile databases for contamination detection. It is better to prevent contamination prior to DNA typing than identify it after samples are processed. To this end, laboratories may UV irradiate or autoclave consumables prior to use but treatment procedures are typically based on killing microorganisms and not on the elimination of DNA. We report a systematic study of UV and autoclave treatments on the persistence of DNA from saliva. This study was undertaken to determine the best decontamination strategy for the removal of DNA from laboratory consumables. We have identified autoclave and UV irradiation procedures that can eliminate nanogram quantities of contaminating DNA contained within cellular material. Autoclaving is more effective than UV irradiation because it can eliminate short fragments of contaminating DNA more effectively. Lengthy autoclave or UV irradiation treatments are required. Depending on bulb power, a UV crosslinker may take a minimum of 2h to achieve an effective dose for elimination of nanogram quantities of contaminating DNA (>7250mJ/cm(2)). Similarly autoclaving may also take 2h to eliminate similar quantities of contaminating DNA. For this study, we used dried saliva stains to determine the effective dose. Dried saliva stains were chosen because purified DNA as well as fresh saliva are less difficult to eradicate than dried stains and also because consumable contamination is more likely to be in the form of a collection of dry cells.

  13. One-step formation and sterilization of gellan and hyaluronan nanohydrogels using autoclave.

    Science.gov (United States)

    Montanari, Elita; De Rugeriis, Maria Cristina; Di Meo, Chiara; Censi, Roberta; Coviello, Tommasina; Alhaique, Franco; Matricardi, Pietro

    2015-01-01

    The sterilization of nanoparticles for biomedical applications is one of the challenges that must be faced in the development of nanoparticulate systems. Usually, autoclave sterilization cannot be applied because of stability concerns when polymeric nanoparticles are involved. This paper describes an innovative method which allows to obtain, using a single step autoclave procedure, the preparation and, at the same time, the sterilization of self-assembling nanohydrogels (NHs) obtained with cholesterol-derivatized gellan and hyaluronic acid. Moreover, by using this approach, NHs, while formed in the autoclave, can be easily loaded with drugs. The obtained NHs dispersion can be lyophilized in the presence of a cryoprotectant, leading to the original NHs after re-dispersion in water.

  14. Monoclinic phase transformation and mechanical durability of zirconia ceramic after fatigue and autoclave aging.

    Science.gov (United States)

    Mota, Yasmine A; Cotes, Caroline; Carvalho, Rodrigo F; Machado, João P B; Leite, Fabíola P P; Souza, Rodrigo O A; Özcan, Mutlu

    2017-10-01

    This study evaluated the influence of two aging procedures on the biaxial flexural strength of yttria-stabilized tetragonal zirconia ceramics. Disc-shaped zirconia specimens and (ZE: E.max ZirCAD, Ivoclar; ZT: Zirkon Translucent, Zirkonzahn) (N = 80) (∅:12 mm; thickness:1.2 mm, ISO 6872) were prepared and randomly divided into four groups (n = 10 per group) according to the aging procedures: C: Control, no aging; M: mechanical cycling (2 × 10 6 cycles/3.8 Hz/200 N); AUT: Aging in autoclave at 134°C, 2 bar for 24 h; AUT + M: Autoclave aging followed by mechanical cycling. After aging, the transformed monoclinic zirconia (%) were evaluated using X-ray diffraction and surface roughness was measured using atomic force microscopy. The average grain size was measured by scanning electron microscopy and the specimens were submitted to biaxial flexural strength testing (1 mm/min, 1000 kgf in water). Data (MPa) were statistically analyzed using 2-way analysis of variance and Tukey's test (α = 0.05). Aging procedures significantly affected (p = 0.000) the flexural strength data but the effect of zirconia type was not significant (p = 0.657). AUT ZT (936.4 ± 120.9 b ) and AUT + M ZE (867.2 ± 49.3 b ) groups presented significantly higher values (p autoclave aging alone or with mechanical aging increased the flexure strength but also induced higher transformation from tetragonal to monoclinic phase in both zirconia materials tested. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 1972-1977, 2017. © 2016 Wiley Periodicals, Inc.

  15. Elastic and inelastic scattering of 180 MeV π+- on 24Mg

    International Nuclear Information System (INIS)

    Gmitro, M.; Kvasil, J.; Mach, R.

    1982-01-01

    Equations of the coupled channel method written in the momentum space are solved for the scattering of 180 MeV pions on 24 Mg. The elastic and inelastic differential cross sections are calculated by using the nuclear ground-state- and transition-densities, which describe correctly the (e, e') data for the same nuclear states. The results agree well with the recent (π, π') data [ru

  16. Effect of autoclave postpolymerization treatments on the fracture toughness of autopolymerizing dental acrylic resins.

    Science.gov (United States)

    Durkan, Rukiye; Gürbüz, Ayhan; Yilmaz, Burak; Özel, M Birol; Bağış, Bora

    2012-06-26

    Microwave and water bath postpolymerization have been suggested as methods to improve the mechanical properties of heat and autopolymerizing acrylic resins. However, the effects of autoclave heating on the fracture properties of autopolymerizing acrylic resins have not been investigated. The aim of this study was to assess the effectiveness of various autoclave postpolymerization methods on the fracture properties of 3 different autopolymerizing acrylic resins. Forty-two specimens of 3 different autopolymerizing acrylic resins (Orthocryl, Paladent RR and Futurajet) were fabricated (40x8x4mm), and each group was further divided into 6 subgroups (n=7). Control group specimens remained as processed (Group 1). The first test group was postpolymerized in a cassette autoclave at 135°C for 6 minutes and the other groups were postpolymerized in a conventional autoclave at 130°C using different time settings (5, 10, 20 or 30 minutes). Fracture toughness was then measured with a three-point bending test. Data were analyzed by ANOVA followed by the Duncan test (α=0.05). The fracture toughness of Orthocryl and Paladent-RR acrylic resins significantly increased following conventional autoclave postpolymerization at 130°C for 10 minutes (Pautoclave postpolymerized Futurajet was not significantly different than its control specimens (Pautoclaved at 130°C for 10 minutes. Within the limitations of this study, it can be suggested that autoclave postpolymerization is an effective method for increasing the fracture toughness of tested autoploymerized acrylic resins.

  17. No-Oven, No-Autoclave, Composite Processing, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Cornerstone Research Group Inc. (CRG) proposes to continue the efforts from the 2010 NASA SBIR Phase I topic X5.03, "No-Oven, No-Autoclave (NONA) Composite...

  18. Water radiolysis in extreme conditions of temperature and LET. Scavenging of HO. by Br- ions

    International Nuclear Information System (INIS)

    Saffre, Dimitri

    2011-01-01

    The purpose of this thesis is to contribute to the understanding of the oxidation mechanism of Br - in which the HO . radical is involved. The HO . radiolytic yield is strongly connected with the oxidation yield of Br - , and therefore we have studied the influence of different physical and chemical parameters on this global yield: temperature, LET, dose rate, pH, saturation gas. The solutions have been irradiated with 4 types of ionizing rays: X-rays (from 13 to 18 keV), electrons (from 7 to 10 MeV), C 6+ -ions beam of 975 MeV and He 2+ -ions beam of 70 MeV. The development of an optical autoclave with solution flow, compatible with high LET ionizing rays has allowed us conduct the first experiments at constant high LET and high temperature. This cell has turned out to be compatible with the picosecond pump-probe experiments performed with the ELYSE accelerator. The HO . scavenging yield has been, therefore, estimated at both high LET and high temperature. A better understanding of the Br - oxidation mechanism has been achieved, in acid medium, in particular, by comparing the kinetics results with Monte Carlo Simulations for time scales inferior to the microsecond and with Chemsimul for the stable products (Br 2 .- and Br 3 - formations). (author) [fr

  19. High-impact strength acrylic denture base material processed by autoclave.

    Science.gov (United States)

    Abdulwahhab, Salwan Sami

    2013-10-01

    To investigate the effect of two different cycles of autoclave processing on the transverse strength, impact strength, surface hardness and the porosity of high-impact strength acrylic denture base material. High Impact Acryl was the heat-cured acrylic denture base material included in the study. A total of 120 specimens were prepared, the specimens were grouped into: control groups in which high-impact strength acrylic resins processed by conventional water-bath processing technique (74°C for 1.5 h then boil for 30 min) and experimental groups in which high-impact strength acrylic resins processed by autoclave at 121°C, 210 kPa .The experimental groups were divided into (fast) groups for 15 min, and (slow) groups for 30 min. To study the effect of the autoclave processing (Tuttnauer 2540EA), four tests were conducted transverse strength (Instron universal testing machine), impact strength (Charpy tester), surface hardness (shore D), and porosity test. The results were analyzed to ANOVA and LSD test. In ANOVA test, there were highly significant differences between the results of the processing techniques in transverse, impact, hardness, and porosity test. The LSD test showed a significant difference between control and fast groups in transverse and hardness tests and a non-significant difference in impact test and a highly significant difference in porosity test; while, there were a highly significant differences between control and slow groups in all examined tests; finally, there were a non-significant difference between fast and slow groups in transverse and porosity tests and a highly significant difference in impact and hardness tests. In the autoclave processing technique, the slow (long) curing cycle improved the tested physical and mechanical properties as compared with the fast (short) curing cycle. The autoclave processing technique improved the tested physical and mechanical properties of High Impact Acryl. Copyright © 2013 Japan Prosthodontic Society

  20. Pilot scale high solids anaerobic digestion of steam autoclaved municipal solid waste (MSW) pulp

    Science.gov (United States)

    Steam autoclaving is an efficient method for the separation and recovery of nearly all organics from MSW, yet a reliable alternative outlet for the large volume of organics produced has not yet been successfully demonstrated. The material produced by the autoclave contains a high concentration of s...

  1. Experiments and numerical simulations of flow field and heat transfer coefficients inside an autoclave model

    Science.gov (United States)

    Ghamlouch, T.; Roux, S.; Bailleul, J.-L.; Lefèvre, N.; Sobotka, V.

    2017-10-01

    Today's aerospace industrial first priority is the quality improvement of the composite material parts with the reduction of the manufacturing time in order to increase their quality/cost ratio. A fabrication method that could meet these specifications especially for large parts is the autoclave curing process. In fact the autoclave molding ensures the thermal control of the composite parts during the whole curing cycle. However the geometry of the tools as well as their positioning in the autoclave induce non uniform and complex flows around composite parts. This heterogeneity implies non-uniform heat transfers which can directly impact on part quality. One of the main challenges is therefore to describe the flow field inside an autoclave as well as the convective heat transfer from the heated pressurized gas to the composite part and the mold. For this purpose, and given the technical issues associated with instrumentation and measurements in actual autoclaves, an autoclave model was designed and then manufactured based on similarity laws. This tool allows the measurement of the flow field around representative real industrial molds using the PIV technique and the characterization of the heat transfer thanks to thermal instrumentation. The experimental results are then compared with those derived from numerical simulations using a commercial RANS CFD code. This study aims at developing a semi-empirical approach for the prediction of the heat transfer coefficient around the parts and therefore predicts its thermal history during the process with a view of optimization.

  2. Direct synthesis of Fe3 C-functionalized graphene by high temperature autoclave pyrolysis for oxygen reduction.

    Science.gov (United States)

    Hu, Yang; Jensen, Jens Oluf; Zhang, Wei; Huang, Yunjie; Cleemann, Lars N; Xing, Wei; Bjerrum, Niels J; Li, Qingfeng

    2014-08-01

    We present a novel approach to direct fabrication of few-layer graphene sheets with encapsulated Fe3 C nanoparticles from pyrolysis of volatile non-graphitic precursors without any substrate. This one-step autoclave approach is facile and potentially scalable for production. Tested as an electrocatalyst, the graphene-based composite exhibited excellent catalytic activity towards the oxygen reduction reaction in alkaline solution with an onset potential of ca. 1.05 V (vs. the reversible hydrogen electrode) and a half-wave potential of 0.83 V, which is comparable to the commercial Pt/C catalyst. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Effect of autoclave devitalization on autograft incorporation and bone morphogenetic protein of tibia in Sprague-Dawley rats

    Directory of Open Access Journals (Sweden)

    Anak A.G.Y. Asmara

    2014-06-01

    Full Text Available Background: Heating process with autoclave is one of limb salvage modalities that are widely used. but the results are not satisfying, due to mechanical bone fragility. However, considering this treatment modality is widely accepted in terms of financial, religion and sociocultural aspects, we conducted a on study rats treated with resection and reconstruction with autoclave heating method to assess bone healing by sequential radiology, histopathologic osteoblasts count, and bone morphogenetic protein (BMP.Methods: Thirty six Sprague-Dawley rats were divided into two groups with one group being the autoclave group and others served as control group. In both groups, the tibial diaphysis was extracted en bloc for 7 mm. All groups were kept for 8 weeks and treated under the same condition except the autoclave group, where the extracted bones were put into autoclave at 134°C for 15 minutes and refixed again with k-wire. We performed radiological examination at 5th and 8th week using Lane and Sandhu radiological score. After extraction, the tibial bones were inspected for histological pattern using Salked modified score, osteoblast quantity counting and BMP-2 values.Results: There were statistically significant diffences between control and autoclave group on radiological score at 5th (5.12 ± 1.6 g vs 3.21 ± 2.42, p = 0.023 and 8th week (6.06 ± 1.71 vs 4.29 ± 2.53, p = 0.040, histological score between groups (6.06 ± 1.14 vs 4.14 ± 1.99, p = 0.005, osteoblast count (p < 0.001, and BMP-2 expression,  respectively.Conclusion: Autoclave recycling autograft lowered the speed of graft incorporation and BMP-2 expression. Therefore, autoclave recycling autograft as a method of limb salvage surgery must be reevaluated and not considered to be applied for treatment in bone malignancy.  

  4. Effect of germination and autoclaving of sprouted finger millet and kidney beans on cyanide content.

    Science.gov (United States)

    Chove, Bernard E; Mamiro, Peter R S

    2010-10-01

    Cyanide contents of locally purchased brown finger millet (Eleusine corocana L. Gaertner) and brown speckled kidney bean seeds (Phaseolus vulgaries var. Rose Coco) were determined using raw, germinated and autoclaved samples. The aim was to establish the extent of cyanide content increase resulting from the germination process and the effectiveness of the autoclaving process on the reduction of cyanide levels in the samples, for safety considerations. Autoclaving was carried out at 121degree C for 20 minutes. It was found that germination increased the cyanide content by 2.11 to 2.14 fold in finger millet for laboratory processed samples. In the case of kidney beans the increment was 1.76 to 1.77 fold for laboratory samples. The increments for field processed samples were in the same range as those for laboratory samples. Autoclaving reduced the cyanide content to between 61.8 and 65.9 % of the original raw contents for finger millet and between 56.6 to 57.8% in the case of kidney beans. The corresponding reductions for field samples were also found to be within the same ranges as the laboratory processed samples. It was concluded that autoclaving significantly reduced the cyanide levels in germinated finger millet and kidney beans.

  5. I–V, C–V and deep level transient spectroscopy study of 24 MeV ...

    Indian Academy of Sciences (India)

    This paper describes the effect of 24 MeV proton irradiation on the electrical characteristics of a pnp bipolar junction transistor 2N 2905A. –, – and DLTS measurements are carried out to characterize the transistor before and after irradiation. The properties of deep level defects observed in the bulk of the transistor are ...

  6. Quality evaluation of carbonaceous industrial by-products and its effect on properties of autoclave aerated concrete

    Science.gov (United States)

    Fomina, E. V.; Lesovik, V. S.; Fomin, A. E.; Kozhukhova, N. I.; Lebedev, M. S.

    2018-03-01

    Argillite is a carbonaceous industrial by-product that is a potential source in environmentally friendly and source-saving construction industry. In this research, chemical and mineral composition as well as particle size distribution of argillite were studied and used to develop autoclave aerated concrete as partial substitute of quartz sand. Effect of the argillite as a mineral admixture in autoclave aerated concrete was investigated in terms of compressive and tensile strength, density, heat conductivity etc. The obtained results demonstrated an efficiency of argillite as an energy-saving material in autoclave construction composites.

  7. PREPARATION OF ULTRA-LOW VOLUME WEIGHT AUTOCLAVED AERATED CONCRETE

    Directory of Open Access Journals (Sweden)

    Ondrej Koutny

    2016-12-01

    Full Text Available Autoclaved aerated concrete is a modern construction material that gains its popularity especially due to its thermal insulation performance resulting from low volume weight and porous structure with sufficient mechanical strength. Nowadays, there are attempts to use this material for thermal insulation purposes and to replace current systems, which have many disadvantages, mainly concerning durability. The key for improvement of thermal insulation properties is therefore obtaining a material based on autoclaved aerated concrete with extremely low volume weight (below 200 kg/m ³ ensuring good thermal isolation properties, but with sufficient mechanical properties to allow easy manipulation. This material can be prepared by foaming very fine powder materials such as silica fume or very finely ground sand. This paper deals with the possibilities of preparation and summarizes the basic requirements for successful preparation of such a material.

  8. A Comparison of the Properties of Carbon Fiber Epoxy Composites Produced by Non-autoclave with Vacuum Bag Only Prepreg and Autoclave Process

    Science.gov (United States)

    Park, Sang Yoon; Choi, Chi Hoon; Choi, Won Jong; Hwang, Seong Soon

    2018-05-01

    The non-autoclave curing technique with vacuum bag only (VBO) prepreg has been conceived as a cost-effective manufacturing method for producing high-quality composite part. This study demonstrated the feasibility of improving composite part's performances and established the effective mitigation strategies for manufacturing induced defects, such as internal voids and surface porosity. The experimental results highlighted the fact that voids and surface porosity were clearly dependent on the resin viscosity state at an intermediate dwell stage of the curing process. Thereafter, the enhancement of resin flow could lead to achieving high quality parts with minimal void content (1.3%) and high fiber fraction (53 vol.%). The mechanical testing showed comparable in-plane shear and compressive strength to conventional autoclave. The microscopic observations also supported the evidence of improved interfacial bonding in terms of excellent fiber wet-out and minimal void content for the optimized cure cycle condition.

  9. Monitoring cure properties of out-of-autoclave BMI composites using IFPI sensor

    Science.gov (United States)

    Kaur, Amardeep; Anandan, Sudharshan; Yuan, Lei; Watkins, Steve E.; Chandrashekhara, K.; Xiao, Hai; Phan, Nam

    2016-04-01

    A non-destructive technique for inspection of a Bismaleimide (BMI) composite is presented using an optical fiber sensor. High performance BMI composites are used for Aerospace application for their mechanical strength. They are also used as an alternative to toughened epoxy resins. A femtosecond-laser-inscribed Intrinsic Fabry-Perot Interferometer (IFPI) sensor is used to perform real time cure monitoring of a BMI composite. The composite is cured using the out-of-autoclave (OOA) process. The IFPI sensor was used for in-situ monitoring; different curing stages are analyzed throughout the curing process. Temperature-induced-strain was measured to analyze the cure properties. The IFPI structure comprises of two reflecting mirrors inscribed on the core of the fiber using a femtosecond-laser manufacturing process. The manufacturing process makes the sensor thermally stable and robust for embedded applications. The sensor can withstand very high temperatures of up to 850 °C. The temperature and strain sensitivities of embedded IFPI sensor were measured to be 1.4 pm/μepsilon and 0.6 pm/μepsilon respectively.

  10. Effect of high-dose irradiation and autoclave treatment on microbial safety and quality of ready-to-eat Bulgogi sauce

    International Nuclear Information System (INIS)

    Park, Jin-Gyu; Song, Beom-Seok; Kim, Jae-Hun; Han, In-Jun; Yoon, Yohan; Chung, Hyung-Wook; Kim, Eun-Jeong; Gao Meixu; Lee, Ju-Woon

    2012-01-01

    In Korea, commercialized sauce for ready-to-eat (RTE) Bulgogi is usually manufactured using heat treatment to ensure that it has a long shelf-life. However, heat treatment may adversely affect the taste and flavor of the sauce, thus, the development of suitable sterilizing methods for RTE sauces is necessary to preserve the quality of the sauce during long storage periods. In this study, total bacterial growth, the viscosity, and the sensory properties of Bulgogi sauce were compared between sterilization with gamma irradiation (0–40 kGy) and autoclave treatment during storage at 35 °C for 90 days. No bacterial growth was observed following irradiation at more than 10 kGy or after autoclave treatment. However, the viscosity and sensory properties of samples gamma-irradiated at above 10 kGy or autoclave-treated were significantly changed, even though autoclave treatment induced a burnt taste and flavor. Therefore, a gamma irradiation of 10 kGy was effective to prepare ready-to-eat Bulgogi sauce with microbial safety and original sensory qualities. - Highlights: ► No bacterial growth in gamma-irradiated Bulgogi sauce ≥10 kGy or autoclaved sample was observed. ► Viscosity of irradiated sample at 40 kGy was similar to that of autoclaved sample. ► Sensory properties of irradiated sample >10 kGy or autoclaved sample deteriorated.

  11. Effect of substrate temperature on the radiation damage from MeV Si implantation in Si

    International Nuclear Information System (INIS)

    Yu, X.K.; Shao Lin; Rusakova, Irene; Wang, X.M.; Ma, K.B.; Chen, H.; Liu, Jiarui; Chu, W.-K.

    2006-01-01

    We have investigated the radiation damage by MeV implantation of Si in Si and its evolution under thermal annealing. Si wafers were implanted with MeV Si at various substrate temperatures. Damages were characterized by Rutherford-backscattering (RBS) channeling and by transmission electron microscopy (TEM). Defect formation after post-implantation annealing is very sensitive to the substrate temperatures during implantation. When the substrate temperature was decreased to 200 K, TEM revealed two distinct bands of damage after annealing: one around the mean projected ion range and another at half the projected range. Our study indicates that the formation of defects at half range results from the solid phase epitaxy growth of initial buried amorphous layers

  12. Influence of addition of calcium sulfate dihydrate on drying of autoclaved aerated concrete

    Science.gov (United States)

    Małaszkiewicz, Dorota; Chojnowski, Jacek

    2017-11-01

    The quality of the autoclaved aerated concrete (AAC) strongly depends on the chemical composition of the raw materials, as well as on the process of the hydrothermal reaction during autoclaving. Performance parameters depend on material structure: fine micron-scale matrix porosity generated by the packing of thin tobermorite plates and coarse aeration pores arising from the foaming of wet mix. In this study the binder varied in calcium sulfate dihydrate (CaSO4ṡ2H2O) content. Five series of AAC specimens were produced, with gypsum content 0; 0.55; 1.15; 2.3 and 3.5% of dry mass respectively. AAC units were produced in UNIPOL technology. The study presents experimental results of AAC moisture stabilization. The initial moisture content was determined directly after autoclaving. Slower drying process was observed for samples containing over 2% of gypsum. Whereas other performance parameters, compressive and tensile strength, as well as water absorption and capillary rise, were significantly better comparing to the reference AAC samples.

  13. Autoclave Sterilization of PEDOT:PSS Electrophysiology Devices.

    Science.gov (United States)

    Uguz, Ilke; Ganji, Mehran; Hama, Adel; Tanaka, Atsunori; Inal, Sahika; Youssef, Ahmed; Owens, Roisin M; Quilichini, Pascale P; Ghestem, Antoine; Bernard, Christophe; Dayeh, Shadi A; Malliaras, George G

    2016-12-01

    Autoclaving, the most widely available sterilization method, is applied to poly(3,4-ethylenedioxythiophene) doped with polystyrene sulfonate (PEDOT:PSS) electrophysiology devices. The process does not harm morphology or electrical properties, while it effectively kills E. coli intentionally cultured on the devices. This finding paves the way to widespread introduction of PEDOT:PSS electrophysiology devices to the clinic. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. The use of solar energy for powering a portable autoclave.

    Science.gov (United States)

    Dravid, M N; Chandak, A; Phute, S U; Khadse, R K; Adchitre, H R; Kulkarni, S D

    2012-04-01

    Climate change and the depletion of fossil fuels have forced the developed world to look for clean energy alternatives. Solar cooking is developing in Asian and African countries blessed with ample sun, but is still at an early stage. A portable autoclave was developed in India using this technology. The Prince-40 Concentrator provided adequate capacity to autoclave culture media and treat biomedical waste in a small laboratory set-up, and could save electricity worth Rs. 15,000 (188.10 GBP)/year or LPG worth Rs. 37,500 (470.25 GBP)/year. This technology would be of immense use in health centres in rural areas with frequent power cuts or no power supply. Copyright © 2012 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  15. Effect of multiple autoclave cycles on the surface roughness of HyFlex CM and HyFlex EDM files: an atomic force microscopy study.

    Science.gov (United States)

    Yılmaz, K; Uslu, G; Özyürek, T

    2018-02-13

    To compare the effect of autoclave cycles on the surface topography and roughness of HyFlex CM and HyFlex EDM instruments using atomic force microscopy (AFM) analysis. Eight new files of each brand were subdivided into four subgroups (n = 2/each subgroup). One group was allocated as the control group and not subjected to autoclave sterilization. The other three groups were subjected to different numbers (1, 5, and 10) of autoclave sterilization cycles. After the cycle instruments were subjected to AFM analysis. Roughness average (Ra) and the root mean square (RMS) values were chosen to investigate the surface features of endodontic files. The data was analyzed using one-way ANOVA and post hoc Tamhane tests at 5% significant level. The lowest Ra and RMS values were observed in the HyFlex EDM files that served as the control and in those subjected to a single cycle of autoclave sterilization (P cycles of autoclave sterilization (P cycles, whereas those of the HyFlex EDM group exhibited a significant change after five autoclave cycles (P cycles of autoclave sterilization. In contrast, the surface roughness values of the HyFlex CM files did not increase until 10 cycles of autoclave sterilization. Present study indicated that autoclave sterilization negatively affected the surface roughness of the tested NiTi files.

  16. HYACE - a novel autoclave coring equipment for systematic offshore gashydrate sampling

    Energy Technology Data Exchange (ETDEWEB)

    Amann, H.; Hohnberg, H.J.; Reinelt, R. [Technische Univ. Berlin (Germany). Inst. fuer Schiffs- und Meerestechnik, Fachgebiet Maritime Technik

    1997-12-31

    HYACE, the acronym for hydrate autoclave coring equipment system, is a research and development project sponsored by the European Union`s Marine Science and Technology Programme MAST. The project was to have started in the fourth quarter of 1997 and is to last 30 months. The main activities of the project will be in the development and prototype testing of an innovative down-hole controlled autoclave coring system. This system will be designed to sample marine sediments at extended down-hole conditions maintaining as many parameters constant as possible. In general terms, the main aim of the project is to contribute to systematic ground truthing of a necessarily ephemeral phenomenon of growing global significance: sampling and analysis of gas hydrates in their natural environment. (MSK)

  17. Temperature and 8 MeV electron irradiation effects on GaAs solar cells

    Indian Academy of Sciences (India)

    1Department of Physics, Mangalore Institute of Technology and Engineering, ... strate were irradiated with 1 MeV electrons, they showed high radiation tolerance ... under both forward and reverse bias in the temperature range of 270–315 K ...

  18. Relationship between tolerance factor and temperature coefficient of permittivity of temperature-stable high permittivity BaTiO3–Bi(MeO3 compounds

    Directory of Open Access Journals (Sweden)

    Natthaphon Raengthon

    2016-03-01

    Full Text Available The temperature coefficient of permittivity (TCε of BaTiO3–Bi(MeO3 solid solutions were investigated. It was determined that as the tolerance factor was decreased with the addition of Bi(MeO3, the TCε shifted from large negative values to TCε values approaching zero. It is proposed that the different bonding nature of the dopant cation affects the magnitude and temperature stability of the permittivity. This study suggests that the relationship between tolerance factor and TCε can be used as a guide to design new dielectric compounds exhibiting temperature-stable high permittivity characteristics, which is similar to past research on perovskite and pyrochlore-based microwave dielectrics.

  19. The corrosion rate measurement of Inconel 690 on high temperature and pressure by using CMS100

    International Nuclear Information System (INIS)

    Sriyono; Satmoko, Ari; Febrianto; Hidayati, N R; Arifal; Sumarno, Ady; Handoyo, Ismu; Prasetjo, Joko

    1999-01-01

    The corrosion rate measurement of Inconel 690 on high temperature and pressure had been done. By using an Autoclave, and temperature can be simulated. For reducing the pressure on Autoclave so its can be measure by Corrosion Measurement System 100(CMS100), the electrodes placement had designed and fabrication on the cover of Autoclave. The electrodes of CMS100 are reference electrode, working electrodes and counter electrodes. The electrodes placement are made and and designed on two packages, these are Salt bridge and Counter-specimen placement. From the result of testing these both of placement are able to 90 bar (pressure) and 280 C (temperature) operation rate measurement was done on temperature variation from 150 0C, 190 0C, 200 0C, 210 0C, 220 0C and 230 0C, and the solution is 0.1 ppm chloride. The pressure experiment is the pressure, which occurred in Autoclave. From the Tafel analysis, even through very little The corrosion current increased from 150 C to 230 C it is 2,54x10-10 a/cm2 to 1,62x10-9 A/cm2, but the the corrosion rate is still zero

  20. Damage accumulation in MgO irradiated with MeV Au ions at elevated temperatures

    Energy Technology Data Exchange (ETDEWEB)

    Bachiller-Perea, Diana, E-mail: dianabachillerperea@gmail.com [Centre de Sciences Nucléaires et de Sciences de la Matière (CSNSM), Univ. Paris-Sud, CNRS-IN2P3, Université Paris-Saclay, 91405, Orsay Cedex (France); Centro de Micro-Análisis de Materiales, Universidad Autónoma de Madrid, C/Faraday 3, 28049, Madrid (Spain); Dpto. de Física Aplicada, Universidad Autónoma de Madrid, Ciudad Universitaria de Cantoblanco, 28049, Madrid (Spain); Debelle, Aurélien, E-mail: aurelien.debelle@u-psud.fr [Centre de Sciences Nucléaires et de Sciences de la Matière (CSNSM), Univ. Paris-Sud, CNRS-IN2P3, Université Paris-Saclay, 91405, Orsay Cedex (France); Thomé, Lionel [Centre de Sciences Nucléaires et de Sciences de la Matière (CSNSM), Univ. Paris-Sud, CNRS-IN2P3, Université Paris-Saclay, 91405, Orsay Cedex (France); Behar, Moni [Instituto de Física, Universidade Federal do Rio Grande do Sul, C.P. 15051, 91501-970, Porto Alegre, RS (Brazil)

    2016-09-15

    The damage accumulation process in MgO single crystals under medium-energy heavy ion irradiation (1.2 MeV Au) at fluences up to 4 × 10{sup 14} cm{sup −2} has been studied at three different temperatures: 573, 773, and 1073 K. Disorder depth profiles have been determined through the use of the Rutherford backscattering spectrometry in channeling configuration (RBS/C). The analysis of the RBS/C data reveals two steps in the MgO damage process, irrespective of the temperature. However, we find that for increasing irradiation temperature, the damage level decreases and the fluence at which the second step takes place increases. A shift of the damage peak at increasing fluence is observed for the three temperatures, although the position of the peak depends on the temperature. These results can be explained by an enhanced defect mobility which facilitates defect migration and may favor defect annealing. X-ray diffraction reciprocal space maps confirm the results obtained with the RBS/C technique. - Highlights: • High-temperature MeV-ion irradiated MgO exhibits a two-step damage process. • The occurrence of the second step is delayed with increasing temperature. • The damage level decreases with increasing temperature. • A shift of the damage peak is observed with increasing fluence. • A high defect mobility at high temperatures in MgO is clearly evidenced.

  1. Application of glass recycling by-products in Autoclaved Aerated Concrete

    NARCIS (Netherlands)

    Straub, Chr.; Florea, M.V.A.; Brouwers, H.J.H.; Schmidt, Wolfram; Msinjili, Nsesheye Susan

    Autoclaved Aerated Concrete (AAC) is a construction material with a large range of applications. In order to generate more sustainable materials, the possibility of the incorporation of by-products and left-over-materials from various processes is investigated. The focus of this research is the

  2. A Method for Out-of-autoclave Fabrication of High Fiber Volume Fraction Fiber Reinforced Polymer Composites

    Science.gov (United States)

    2012-07-01

    5 Figure 5. (a) (Left) Results showing optimal compaction of an E-glass (similar compaction to S-Glass) laminate at approximately 350...repeatability and a lack in dimensional tolerances versus prepreg composites fabricated in an autoclave. However, recent advancements in process understanding...structure, and while high fvf composite laminates are attainable in autoclave processing, these techniques may not be cost effective (10–15). The out

  3. Effect of autoclave processing and gamma irradiation on apparent ...

    African Journals Online (AJOL)

    The objective of this study was to investigate the effect of autoclaving and different doses of gamma irradiation on the apparent ileal digestibility of amino acids of cottonseed meal in male broiler breeders. Samples were irradiated in a gamma cell at total doses of 15, 30 and 45 kGy. One package (control) was left at room ...

  4. Investigation of CFRP in aerospace field and improvement of the molding accuracy by using autoclave

    Science.gov (United States)

    Minamisawa, Takunori

    2017-07-01

    In recent years, CFRP (Carbon Fiber Reinforced Plastic) has come to be used in a wide range of industries such as sporting goods, fishing tackle and cars because it has a large number of advantages. In this situation, even the passenger aircraft industry also pays attention to the material. CFRP is an ideal material for airplanes because it has a lot of advantages such as light weight and strong, chemical resistance and corrosion resistance. Generally, autoclave is used for molding CFRP in the field of aerospace engineering. Autoclave is a machine that can mold a product by heating and pressurizing material in an evacuated bag. What is examined in this paper is an observation on handmade CFRP by a polarizing microscope. In addition, mechanical characteristics were investigated. Furthermore, an improvement of accuracy in CFRP molding using an autoclave is suggested from viewpoint of thermodynamics.

  5. Neutron doses to personnel from a 24 MeV betatron

    International Nuclear Information System (INIS)

    Beckham, W.A; Entwistle, R.F.

    1987-01-01

    Neutrons are produced by bombardment of most materials by high-energy photons. Because the x-ray shielding around high-energy x-ray generators may not have been designed with neutrons in mind there may be unexpected contributions to the radiation doses of staff working in the immediate vicinity. Neutron fluxes in the working area close to an Allis-Chalmers 24 MeV betatron have been measured using a lithium-6-loaded scintillator and the dose rates calculated. Hazard of staff has been found to be low; typical dose-equivalent rates in occupied areas range from 0.0042 to 0.012 mrem/hour. The flux of fast neutrons in the treatment room was found to be essentially zero. Measurements of neutron flux may be routinely performed using the scintillation detector (NE 912) described, and could usefully form part of the acceptance protocol for any new accelerator

  6. Studies of Redox Equilibria at Elevated Temperatures 2. An Automatic Divided-Function Autoclave and Cell with Flowing Liquid Junction for Electrochemical Measurements on Aqueous Systems.

    Energy Technology Data Exchange (ETDEWEB)

    Johnsson, Kerstin; Lewis, Derek; Pourbaix, Marian de

    1970-10-15

    An apparatus is described that has been developed for electrochemical studies of aqueous systems at temperatures above 100 deg C. It consists essentially of an electrically heated experimental cell enclosed by a separate pressure-vessel the walls of which are kept cool. This construction eliminates or reduces the problems of sealing electrical connections and of the corrosion of the pressure vessel, that commonly arise with conventional, externally-heated autoclaves. Pressure is applied to the cell by means of compressed air, diaphragm valves at the electrolyte outlet automatically maintaining the pressure in the cell about 1 atm lower than that in the pressure vessel. Two independent streams of electrolyte can be pumped into the experimental cell a special form of which has been developed in which may be formed a galvanic cell with a continuously regenerated flowing-liquid junction. In this form the apparatus enables experiments with, for example, one molal chloride solutions with pH 1-10, at temperatures up to about 250 deg C and under pressures up to about 40 atm. The apparatus has been tested in experiments in which classical measurements of the conductance of some aqueous electrolytes have been repeated. Good agreement with the earlier results has been obtained

  7. Spectroscopic study of {sup 206,207,208}Pb isotopes by high resolution analysis of 24.5 MeV proton scattering; Etude spectroscopique des isotopes 206, 207 et 208 du plomb par analyse a haute resolution de la diffusion de protons de 24,5 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Vallois, G [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1968-03-01

    {sup 206,207,208}pb have been studied by 24.5 MeV proton inelastic scattering with a resolution of 20 keV. The angular distributions of the differential cross-sections corresponding to the different excited levels have been measured in a large angular region and analysed with the DWBA.This work shows that it exists between 4 and 5 MeV of excitation energy some strongly excited levels corresponding to transfer momenta l = 2, 4, 6 and 8. The single particle-hole models do not explain these states; so it will probably be necessary to introduce some several particle - hole configurations. (author) [French] Les isotopes 206, 207 et 208 du plomb ont ete etudies par diffusion inelastique de protons de 24,5 MeV avec une resolution de 20 keV. Les distributions angulaires des sections efficaces differentielles correspondant aux differents niveaux excites ont ete mesurees sur un large domaine angulaire et analysees a l'aide de la DWBA. Ce travail met en evidence l'existence, entre 4 et 5 MeV d'excitation, de niveaux fortement excites correspondant a des moments de transfert de 2, 4, 6 et 8. Les modeles a simple particule-trou ne rendant pas compte de ces niveaux, il faudra sans doute recourir a des configurations a plusieurs particules-trous pour les expliquer. (auteur)

  8. Synthesis of marasin and 9-Me-marasin (nona- and deca-6,8-diyne-2,4-dienol)

    NARCIS (Netherlands)

    Koten, G. van; Graaf, W. de; Smits, A.; Boersma, J.; Hoekstra, W.P.M.

    1988-01-01

    3, 4-Pentadienol was protected with ethyl vinyl ether and regioselectively (70%) deprotonated at the terminal position by treatment with BuLi in THF at low temperature. Starting from the so obtained lithium compound, Marasin (nona-6,8-diyne-3,4-dienol) (1a) and 9-Me-Marasin

  9. Development of an autoclave with zirconia crystal windows for in-situ observation of sample surface under primary water conditions of pressurized water reactors

    Energy Technology Data Exchange (ETDEWEB)

    Fukumura, Takuya; Totsuka, Nobuo; Arioka, Koji [Inst. of Nuclear Safety System Inc., Mihama, Fukui (Japan); Nakajima, Nobuo

    2002-09-01

    Elucidating the mechanism for primary water stress corrosion cracking (PWSCC) is important for improving the reliability of structural materials in the primary system of pressurized water reactors (PWR). For this purpose, visualization of corrosion material surface in the primary coolant environment is effective, but it was impossible because of lack of suitable window material. Yttria stabilized zirconia was newly selected as a candidate for in-situ window material in the primary coolant environment of PWR. Its sufficient corrosion resistance was proved by measuring the transmissivity of light after being immersed in the primary coolant environment. A new autoclave with two windows of yttria-stabilized zirconia was developed. The corrosion material surfaces of Alloy600 and SUS304 in the primary coolant environment were clearly observed with this autoclave. Observations of cracks generated on the surface of SUS304 specimen, suggest that its generation time depends on temperature. (author)

  10. Preparation of extra-small nisin nanoparticles for enhanced antibacterial activity after autoclave treatment.

    Science.gov (United States)

    Chang, Ranran; Lu, Hao; Li, Man; Zhang, Shuangling; Xiong, Liu; Sun, Qingjie

    2018-04-15

    Nisin is applied broadly in the food industry as an antimicrobial peptide. The objective of this study is to prepare nisin nanoparticles using free nisin by a facile nanoprecipitation technique and to investigate their antimicrobial activity after high-temperature processing. Transmission electron microscopic images showed that the size of extra-small nisin nanoparticles with different initial concentrations of nisin (0.1%, 0.3% and 0.5%) was 5, 10 and 15 nm, respectively. The nisin nanoparticles were stable at pH 5.0 with the smallest size. Moreover, nisin nanoparticles exhibited a higher antimicrobial activity than free nisin at a concentration below 2.0 mg/ml after autoclave treatment. These results suggested that nisin nanoparticles could serve as a potential food preservative. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. The (p→,t) reaction on 58Ni and 56Fe at 24.6 MeV

    International Nuclear Information System (INIS)

    Polane, J.H.; Feix, W.F.; Hall, P.J. van; Klein, S.S.; Nijgh, G.J.; Poppema, O.J.; Wassenaar, S.D.

    1989-01-01

    The (p, t) reactions on 56 Fe and 58 Ni initiated by 24.6 MeV polarised protons has been investigated. The reaction process is described in terms of simultaneous and sequential neutron transfer. For all five final states studied the sequential process competes strongly with simultaneous transfer of a neutron pair. Theoretical values for the spectroscopic amplitudes were derived from shell-model wavefunctions; these seem to give a reliable description of the reaction process. (author)

  12. Sodium carbonate activated slag as cement replacement in autoclaved aerated concrete

    NARCIS (Netherlands)

    Yuan, B.; Straub, C.; Segers, S.; Yu, Q.; Brouwers, H.J.H.

    2017-01-01

    This paper aims to study the suitability of fully replacing cement by sodium carbonate activated slag in producing autoclaved aerated concrete (AAC). The material properties of the product are characterized in terms of green strength development, mechanical properties, pore related properties such

  13. Fission lifetime measured by the blocking technique as a function of excitation energy in the 24 A.MeV 238U+28Si reaction

    International Nuclear Information System (INIS)

    Morjean, M.; Galin, J.; Goldenbaum, F.; Lienard, E.; Chevallier, M.; Dauvergne, D.; Kirsch, R.; Jacquet, D.; and others.

    1997-01-01

    The blocking technique was used to infer fission lifetimes as a function of excitation energy for uranium-like nuclei formed in the U+Si reactions at 24 MeV/nucleon. The fission lifetimes are found larger than 10 -19 s for excitation energies up to about 250 MeV. (K.A.)

  14. Scanning electron microscopy of autoclaved aerated concrete with supplementary raw materials

    NARCIS (Netherlands)

    Straub, C.; Florea, M.V.A.; Brouwers, H.J.H.; Nisperos, Arturo G.; Pöllmann, Herbert

    Microscopy is a key analysis technology for the understanding of the achieved properties of building materials. In the case of Autoclaved Aerated Concrete (AAC) it is even more important due to the phase transformation during the hydrothermal hardening. The incorporation of substitution materials in

  15. Carbon Foam Self-Heated Tooling for Out-of-Autoclave Composites Manufacturing, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — This proposal addresses NASA's need for non-autoclave composites manufacture. The Constellation program, including the Ares V launch vehicle, will require very...

  16. Effect of autoclave devitalization on autograft incorporation and bone morphogenetic protein of tibia in Sprague-Dawley rats

    OpenAIRE

    Anak A.G.Y. Asmara; Achmad F. Kamal; Nurjati C. Siregar; Marcel Prasetyo

    2014-01-01

    Background: Heating process with autoclave is one of limb salvage modalities that are widely used. but the results are not satisfying, due to mechanical bone fragility. However, considering this treatment modality is widely accepted in terms of financial, religion and sociocultural aspects, we conducted a on study rats treated with resection and reconstruction with autoclave heating method to assess bone healing by sequential radiology, histopathologic osteoblasts count, and bone morphogeneti...

  17. Application of autoclaving-cooling cycling treatment to improve resistant starch content of corn-based rice analogues

    Science.gov (United States)

    Hidayat, B.; Muslihudin, M.; Akmal, S.

    2018-01-01

    Resistant starch is one important component determining the characteristics of a functional food. The aim of the research was to determine the cooling time optimum in the autoclaving-cooling treatment to increase the resistance starch content corn-based rice analogues, with 6 level of cooling time (0 hours/control, 12 hours, 24 hours, 36 hours, 48 hours and 60 hours). The results showed that cooling at 4°C for 60 hours would increase the resistant starch content (6.27% to 15.38%), dietary fiber content (14.53% to 20.17%); and decrease the digestible starch content (61.81% to 52.70%). Cooling time level at 4°C for 24 hours, would increase the sensory score of corn-based rice analogues then back down until cooling time level of 60 hours. Microscopic analysis of granular structure using SEM indicated that cooling time had a linear correlation with cracks intensity on the granule surface of the corn-based rice analogues. The high content of resistant starch showed that the application of cooling time level at 4°C for 24 hours would improve the functional properties of corn-based rice analogues with sensory characteristics remain favorable to panelists.

  18. Spectroscopic study of 206,207,208Pb isotopes by high resolution analysis of 24.5 MeV proton scattering

    International Nuclear Information System (INIS)

    Vallois, G.

    1968-03-01

    206,207,208 pb have been studied by 24.5 MeV proton inelastic scattering with a resolution of 20 keV. The angular distributions of the differential cross-sections corresponding to the different excited levels have been measured in a large angular region and analysed with the DWBA.This work shows that it exists between 4 and 5 MeV of excitation energy some strongly excited levels corresponding to transfer momenta l = 2, 4, 6 and 8. The single particle-hole models do not explain these states; so it will probably be necessary to introduce some several particle - hole configurations. (author) [fr

  19. Comparison of Composites Properties Manufactured by Vacuum Process and Autoclave Process

    Directory of Open Access Journals (Sweden)

    MA Rufei

    2017-01-01

    Full Text Available Two kinds of prepregs ZT7G/LT-03A(unidirectional carbon fiber prepreg and ZT7G3198P/LT-03A(plain carbon fabric prepreg were used to manufacture three Bateches of composites by vacuum process and autoclave process respectively. The physical properties of the prepregs and mechanical properties of composite were tested. The performance, fiber volume content and porosity of composites manufactured by vacuum cure and autoclave process show that the physical property retention rates of vacuum cured composites are all over 75%, some even more than 100%. Interlaminar shear strength keeps the lowest retention rate and warp tensile strength keeps the highest retention in unidirectional carbon fiber composites. For fabric composite material, compression strength keeps the lowest and warp tensile strength keeps the highest retention. Vacuum cured composites perform lower fiber volume content and higher porosity, which are the main reasons of the lower performance.

  20. 24/7 Connectedness and its Potential Impact on Today’s Physics Students: Technology Use, Multitasking, and GenMe

    Directory of Open Access Journals (Sweden)

    Teresa L. Larkin

    2018-05-01

    Full Text Available There is no question that the digital age is upon us. For many of us, the trans-formation to the digital age has been gradual; and, most often, welcomed. In the classroom, we have developed many useful and innovative applications technolo-gy-based pedagogies. Outside of the classroom, we use routinely rely on tech-nology to communicate with our students. However, not all of us grew up with 24/7 access to information that the internet and today’s technologies provide. Perhaps the impact of technology on those of us that teach is a bit different from the impact on our students. Many of our students today are members of the mil-lennial generation, which is sometimes referred to as Generation Me (GenMe. Members of GenMe have literally grown up with technology and the instantane-ous availability of information right at their fingertips. Computers, smart phones, iPads, and other technologies offer their users immediate access to information. Might these technologies be seen as a significant distraction to whatever the task at hand might be? Could these distractions be to blame for the perception of many in GenMe that they must multitask in order to get everything done? Might instant access to information be casting a cloud on student learning? If so, does this cloud have a silver lining? This paper addresses these and other questions through the use of a survey given to students in a second-level physics course in spring 2016. Results reveal that nearly all students feel the need to maintain this 24/7 connection using their smart phones. The impact that this level of connect-edness may have on our students will be discussed.

  1. Effect of high-dose irradiation and autoclave treatment on microbial safety and quality of ready-to-eat Bulgogi sauce

    Science.gov (United States)

    Park, Jin-Gyu; Song, Beom-Seok; Kim, Jae-Hun; Han, In-Jun; Yoon, Yohan; Chung, Hyung-Wook; Kim, Eun-Jeong; Gao, Meixu; Lee, Ju-Woon

    2012-08-01

    In Korea, commercialized sauce for ready-to-eat (RTE) Bulgogi is usually manufactured using heat treatment to ensure that it has a long shelf-life. However, heat treatment may adversely affect the taste and flavor of the sauce, thus, the development of suitable sterilizing methods for RTE sauces is necessary to preserve the quality of the sauce during long storage periods. In this study, total bacterial growth, the viscosity, and the sensory properties of Bulgogi sauce were compared between sterilization with gamma irradiation (0-40 kGy) and autoclave treatment during storage at 35 °C for 90 days. No bacterial growth was observed following irradiation at more than 10 kGy or after autoclave treatment. However, the viscosity and sensory properties of samples gamma-irradiated at above 10 kGy or autoclave-treated were significantly changed, even though autoclave treatment induced a burnt taste and flavor. Therefore, a gamma irradiation of 10 kGy was effective to prepare ready-to-eat Bulgogi sauce with microbial safety and original sensory qualities.

  2. Calorimetry for absorbed dose measurement at 1-4 MeV electron accelerators

    International Nuclear Information System (INIS)

    Miller, A.

    2000-01-01

    Calorimeters are used for dose measurement, calibration and intercomparisons at industrial electron accelerators, and their use at 10 MeV electron accelerators is well documented. The work under this research agreement concerns development of calorimeters for use at electron accelerators with energies in the range of 2-4 MeV. The dose range of the calorimeters is 3-40 kGy, and their temperature stability after irradiation was found to be sufficient for practical use in an industrial environment. Measurement uncertainties were determined to be 5% at k = 2. (author)

  3. Gamow-Teller matrix elements from the C-12(d,He-2) and Mg-24(d,He-2) reactions at 170 MeV

    NARCIS (Netherlands)

    Baumer, C; Frekers, D; Schmidt, R; van den Berg, AM; Hannen, VM; Harakeh, MN; de Huu, MA; Wörtche, HJ; De Frenne, D; Hagemann, M; Heyse, J; Jacobs, E; Fujita, Y

    The Mg-24(d,He-2)Na-24 and the C-12(d,He-2)B-12 charge-exchange reactions have been studied at an incident energy of 170 MeV. The two protons in the S-1(0)(pp) state (indicated as He-2) were both momentum analyzed and detected by the same spectrometer and detector. Background-free He-2 spectra with

  4. Effect of autoclave sterilization on the cyclic fatigue resistance of thermally treated Nickel-Titanium instruments.

    Science.gov (United States)

    Zhao, D; Shen, Y; Peng, B; Haapasalo, M

    2016-10-01

    To compare the cyclic fatigue resistance of HyFlex CM, Twisted Files (TF), K3XF, Race, and K3, and evaluate the effect of autoclave sterilization on the cyclic fatigue resistance of these instruments both before and after the files were cycled. Five types of NiTi instruments with similar size 30, .06 taper were selected: HyFlex CM, TF, K3XF, Race and K3. Files were tested in a simulated canal with a curvature of 60° and a radius of 3 mm. The number of cycles to failure of each instrument was determined to evaluate cyclic fatigue resistance. Each type of instruments was randomly divided into four experimental groups: group 1 (n = 20), unsterilized instruments; group 2 (n = 20), pre-sterilized instruments subjected to 10 cycles of autoclave sterilization; group 3 (n = 20), instruments tested were sterilized at 25%, 50% and 75% of the mean cycles to failure as determined in group 1, and then cycled to failure; group 4 (n = 20), instruments cycled in the same manner as group 3 but without sterilization. The fracture surfaces of instruments were examined by scanning electron microscopy (SEM). HyFlex CM, TF and K3XF had significantly higher cyclic fatigue resistance than Race and K3 in the unsterilized group 1 (P Autoclave sterilization significantly increased the MCF of HyFlex CM and K3XF (P Autoclaving extended the cyclic fatigue life of HyFlex CM and K3XF. © 2015 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  5. NASA Out-of-Autoclave Process Technology Development

    Science.gov (United States)

    Johnston, Norman, J.; Clinton, R. G., Jr.; McMahon, William M.

    2000-01-01

    Polymer matrix composites (PMCS) will play a significant role in the construction of large reusable launch vehicles (RLVs), mankind's future major access to low earth orbit and the international space station. PMCs are lightweight and offer attractive economies of scale and automated fabrication methodology. Fabrication of large RLV structures will require non-autoclave methods which have yet to be matured including (1) thermoplastic forming: heated head robotic tape placement, sheet extrusion, pultrusion, molding and forming; (2) electron beam curing: bulk and ply-by-ply automated placement; (3) RTM and VARTM. Research sponsored by NASA in industrial and NASA laboratories on automated placement techniques involving the first 2 categories will be presented.

  6. 24-h core temperature in obese and lean men and women.

    Science.gov (United States)

    Hoffmann, Mindy E; Rodriguez, Sarah M; Zeiss, Dinah M; Wachsberg, Kelley N; Kushner, Robert F; Landsberg, Lewis; Linsenmeier, Robert A

    2012-08-01

    Maintenance of core temperature is a major component of 24-h energy expenditure, and its dysregulation could contribute to the pathophysiology of obesity. The relationship among temperature, sex, and BMI, however, has not been fully elucidated in humans. This study investigated core temperature in obese and lean individuals at rest, during 20-min exercise, during sleep, and after food consumption. Twelve lean (18.5-24.9 kg/m(2)) and twelve obese (30.0-39.9 kg/m(2)) healthy participants, ages 25-40 years old, were admitted overnight in a clinical research unit. Females were measured in the follicular menstrual phase. Core temperature was measured every minute for 24 h using the CorTemp system, a pill-sized sensor that measures core temperature while in the gastrointestinal tract and delivers the measurement via a radio signal to an external recorder. Core temperature did not differ significantly between the obese and lean individuals at rest, postmeals, during exercise, or during sleep (P > 0.5), but core temperature averaged over the entire study was significantly higher (0.1-0.2 °C) in the obese (P = 0.023). Each individual's temperature varied considerably during the study, but at all times, and across the entire study, women were ~0.4 °C warmer than men (P < 0.0001). These data indicate that obesity is not associated with a lower core temperature but that women have a higher core temperature than men at rest, during sleep, during exercise, and after meals.

  7. Nonlinear Modeling of Autoclaved Aerated Concrete Masonry Wall Strengthened using Ferrocement Sandwich Structure

    KAUST Repository

    M., Abdel-Mooty; M., El-Kashef; E., Fahmy; M., Abou-Zeid; M., Haroun

    2011-01-01

    Autoclaved Aerated Concrete (AAC) block are used mainly as non-load-bearing walls that provide heat insulation. This results in considerable saving in cooling energy particularly in hot desert environment with large variation of daily and seasonal

  8. Autoclave growth, magnetic, and optical properties of GdB6 nanowires

    Science.gov (United States)

    Han, Wei; Wang, Zhen; Li, Qidong; Liu, Huatao; Fan, Qinghua; Dong, Youzhong; Kuang, Quan; Zhao, Yanming

    2017-12-01

    High-quality single crystalline gadolinium hexaboride (GdB6) nanowires have been successfully prepared at very low temperatures of 200-240 °C by a high pressure solid state (HPSS) method in an autoclave with a new chemical reaction route, where Gd, H3BO3, Mg and I2 were used as raw materials. The crystal structure, morphology, valence, magnetic and optical absorption properties were investigated using XRD, FESEM, HRTEM, XPS, SQUID magnetometry and optical measurements. HRTEM images and SAED patterns reveal that the GdB6 nanowires are single crystalline with a preferred growth direction along [001]. The XPS spectrum suggests that the valence of Gd ion in GdB6 is trivalent. The effective magnetic momentum per Gd3+ in GdB6 is about 6.26 μB. The optical properties exhibit weak absorption in the visible light range, but relatively strong absorbance in the NIR and UV range. Low work function and high NIR absorption can make GdB6 nanowires a potential solar radiation shielding material for solar cells or other NIR blocking applications.

  9. Failure Predictions of Out-of-Autoclave Sandwich Joints with Delaminations Under Flexure Loads

    Science.gov (United States)

    Nordendale, Nikolas A.; Goyal, Vinay K.; Lundgren, Eric C.; Patel, Dhruv N.; Farrokh, Babak; Jones, Justin; Fischetti, Grace; Segal, Kenneth N.

    2015-01-01

    An analysis and a test program was conducted to investigate the damage tolerance of composite sandwich joints. The joints contained a single circular delamination between the face-sheet and the doubler. The coupons were fabricated through out-of-autoclave (OOA) processes, a technology NASA is investigating for joining large composite sections. The four-point bend flexure test was used to induce compression loading into the side of the joint where the delamination was placed. The compression side was chosen since it tends to be one of the most critical loads in launch vehicles. Autoclave cure was used to manufacture the composite sandwich sections, while the doubler was co-bonded onto the sandwich face-sheet using an OOA process after sandwich panels were cured. A building block approach was adopted to characterize the mechanical properties of the joint material, including the fracture toughness between the doubler and face-sheet. Twelve four-point-bend samples were tested, six in the sandwich core ribbon orientation and six in sandwich core cross-ribbon direction. Analysis predicted failure initiation and propagation at the pre-delaminated location, consistent with experimental observations. A building block approach using fracture analyses methods predicted failure loads in close agreement with tests. This investigation demonstrated a small strength reduction due to a flaw of significant size compared to the width of the sample. Therefore, concerns of bonding an OOA material to an in-autoclave material was mitigated for the geometries, materials, and load configurations considered.

  10. Impact parameter selected nuclear temperatures of hot nuclei from excited state populations for 40Ar+197Au reactions at E/A=25MeV

    International Nuclear Information System (INIS)

    Li Zuyu; He Zhiyong; Duan Limin; Jin Genming; Wu Heyu; Zhang Baoguo; Wen Wanxin; Qi Yujin; Luo Qingzheng; Dai Guangxi; Wang Hongwei

    1997-01-01

    Nuclear temperatures extracted from excited state populations were measured as a function of linear momentum transfer (LMT) for 40 Ar+ 197 Au reactions at 25MeV/nucleon. The emission temperatures increased slightly with increasing linear momentum transfer or decreasing impact parameter. Taking into account the corrections of detection efficiency and sequential feeding from higher-lying states, a temperature of T∼4MeV was deduced for central collisions. For peripheral collisions the extracted temperatures increased with the energy of the particles. (orig.)

  11. Pressure impact of autoclave treatment on water sorption and pectin composition of flax cellulosic-fibres.

    Science.gov (United States)

    Alix, S; Colasse, L; Morvan, C; Lebrun, L; Marais, S

    2014-02-15

    The tensile properties of flax fibres might permit them to be used in composites as reinforcement in organic resin, as long as their mechanical properties are reproducible and their water sorption are reduced. In this study, to minimise the variability of mechanical properties, several samples of flax fibres were blended as a non-woven fabric. In order to reduce the water absorption of this non-woven technical fibres, an autoclave treatment was performed which was expected to remove the pectins and then to reduce the water sorption on their negative charges. The impact of autoclave pressure (0.5, 1 and 2 bars) on water sorption was investigated by using a gravimetric static equilibrium method. The Park model based on the three sorption modes: Langmuir, Henry's law and clustering, was successfully used to simulate the experimental sorption data. The lowest pressure treatments impacted only the Langmuir contribution while the 2 bar autoclave-treatment positively impacted the water resistance in the core of fibres by reducing Henry's absorption rate. This was shown to be related to the chemical modifications at the surface and in the core of fibres. A schematic model is presented relating the water sorption and the pectic composition of the fabric. Copyright © 2013 Elsevier Ltd. All rights reserved.

  12. Mechanical Characterization of In and Out-of-Autoclave Cured Composite Panels for Large Launch Vehicles

    Science.gov (United States)

    Kellas, Sotiris; Lerch, Bradley A.; Wilmoth, Nathan

    2012-01-01

    Two manufacturing demonstration panels (1/16th-arc-segments of 10 m diameter cylinder) were fabricated under the composites part of the Lightweight Space Structures and Materials program. Both panels were of sandwich construction with aluminum core and 8-ply quasi-isotropic graphite/epoxy facesheets. One of the panels was constructed with in-autoclave curable unidirectional prepreg (IM7/977-3) and the second with out-of-autoclave unidirectional prepreg (T40-800B/5320-1). Following NDE inspection, each panel was divided into a number of small specimens for material property characterization and a large (0.914 m wide by 1.524 m long) panel for a buckling study. Results from the small specimen tests were used to (a) assess the fabrication quality of each 1/16th arc segment panel and (b) to develop and/or verify basic material property inputs to Finite Element analysis models. The mechanical performance of the two material systems is assessed at the coupon level by comparing average measured properties such as flatwise tension, edgewise compression, and facesheet tension. The buckling response of the 0.914 m wide by 1.524 m long panel provided a comparison between the in- and out-of autoclave systems at a larger scale.

  13. Influence of autoclave sterilization on the surface parameters and mechanical properties of six orthodontic wires.

    Science.gov (United States)

    Pernier, C; Grosgogeat, B; Ponsonnet, L; Benay, G; Lissac, M

    2005-02-01

    Orthodontic wires are frequently packaged in individual sealed bags in order to avoid cross-contamination. The instructions on the wrapper generally advise autoclave sterilization of the package and its contents if additional protection is desired. However, sterilization can modify the surface parameters and the mechanical properties of many types of material. The aim of this research was to determine the influence of one of the most widely used sterilization processes, autoclaving (18 minutes at 134 degrees C, as recommended by the French Ministry of Health), on the surface parameters and mechanical properties of six wires currently used in orthodontics (one stainless steel alloy: Tru-Chrome RMO; two nickel-titanium shape memory alloys: Neo Sentalloy and Neo Sentalloy with Ionguard GAC; and three titanium-molybdenum alloys: TMA(R) and Low Friction TMA Ormco and Resolve GAC). The alloys were analysed on receipt and after sterilization, using surface structure observation techniques, including optical, scanning electron and atomic force microscopy and profilometry. The mechanical properties were assessed by three-point bending tests. The results showed that autoclave sterilization had no adverse effects on the surface parameters or on the selected mechanical properties. This supports the possibility for practitioners to systematically sterilize wires before placing them in the oral environment.

  14. Technological parameters influence on the non-autoclaved foam concrete characteristics

    Science.gov (United States)

    Bartenjeva, Ekaterina; Mashkin, Nikolay

    2017-01-01

    Foam concretes are used as effective heat-insulating materials. The porous structure of foam concrete provides good insulating and strength properties that make them possible to be used as heat-insulating structural materials. Optimal structure of non-autoclaved foam concrete depends on both technological factors and properties of technical foam. In this connection, the possibility to manufacture heat-insulation structural foam concrete on a high-speed cavity plant with the usage of protein and synthetic foamers was estimated. This experiment was carried out using mathematical planning method, and in this case mathematical models were developed that demonstrated the dependence of operating performance of foam concrete on foaming and rotation speed of laboratory plant. The following material properties were selected for the investigation: average density, compressive strength, bending strength and thermal conductivity. The influence of laboratory equipment technological parameters on technical foam strength and foam stability coefficient in the cement paste was investigated, physical and mechanical properties of non-autoclaved foam concrete were defined based on investigated foam. As a result of investigation, foam concrete samples were developed with performance parameters ensuring their use in production. The mathematical data gathered demonstrated the dependence of foam concrete performance on the technological regime.

  15. Reaction mechanisms in 24.3 MeV/nucleon 238U induced reactions through a comprehensive study of fission

    International Nuclear Information System (INIS)

    Chbihi, A.; Galin; Guerreau, D.; Lewitowicz, M.; Morjean, M.; Pouthas, J.; Piasecki, E.; Kordyasz, A.; Iwanicki, J.; Jastrzebski, J.; Pienkowski, L.; Crema, E.; Gatty, B.; Jacquet, D.; Muchorowska, M.

    1994-01-01

    Nuclear reaction mechanisms for system characterized by very different asymmetries (U+C, Si, Ni, Au) have been investigated at 24.3 MeV/nucleon, using as observables both the fission products and the neutron multiplicity. It is clearly observed that the fusion process-whatever its completeness- can only occur with rather light target nuclei, indicating the persistence of potential energy effects much above the interaction barrier. (authors). 22 refs., 1 fig

  16. THE INFLUENCE OF A HALLOYSITE ADDITIVE ON THE PERFORMANCE OF AUTOCLAVED AERATED CONCRETE

    Directory of Open Access Journals (Sweden)

    Z. Owsiak

    2015-03-01

    Full Text Available This paper presents the results from the tests of autoclaved aerated concrete with halloysite as a cement additive. Good pozzolanic properties make it a suitable material to be used as a partial replacement of a portion of cement. Basic physical and mechanical properties of the composites with various mineral content are discussed. The compressive strength test results indicate an increase in strength of the AAC containing 2.5 % and 5 % halloysite relative to the reference specimen. Thermal conductivity and density values remained at the same level. Observations of the microstructure in the scanning electron microscope confirmed the results from the XRD tests. Anhydrite was observed in addition to tobermorite. The results from the tests of the autoclaved aerated concretes in which halloysite was incorporated as 7.5 % and 10 % cement replacement showed an increase in compressive strength, density and thermal conductivity values.

  17. West Angeles Community Development Corporation final technical report on export market feasibility planning and research for the solar medical autoclave

    Energy Technology Data Exchange (ETDEWEB)

    Power, G.D.

    1998-04-20

    This report summarizes core findings from an investigation performed by the staff of West Angeles Community Development Corporation (CDC) regarding the feasibility of marketing the Solar Medical Autoclave (``autoclave``) in South Africa. The investigation was completed during 1997, the period prescribed by the Grant Award made by the U.S. Department of Energy on January 1, 1997, and was monitored by the National Renewable Energy Laboratory.

  18. Temperature and excitation energy of hot nuclei in the reaction of 40Ar+197Au at 25 MeV/nucleon

    International Nuclear Information System (INIS)

    Wu, H.; Jin, G.; Li, Z.; Dai, G.; Qi, Y.; He, Z.; Luo, Q.; Duan, L.; Wen, W.; Zhang, B.

    1997-01-01

    The coincidence measurements between heavy fission fragments and light charged particles with Z ≤2 were carried out for the 40 Ar+ 197 Au reaction at 25 MeV/nucleon, to study the properties of hot nuclei in heavy ion induced reactions. The linear momentum transfers (LMTs) were deduced from the folding angle and the time-of-flight difference between two fission fragments of heavy residues. The relationship of the nuclear temperature (slope parameter of the energy spectrum) and the excitation energy was determined independently from the measurement of the kinetic energy spectra in the frames of the emitting sources and from the LMT analysis. Both the temperature and the excitation energy increase with decreasing impact parameter, which suggests that a plateau temperature of 5.5 MeV is reached at an excitation energy of 3.1 MeV/nucleon. The result was also compared with various statistical models that explain the plateau by the multifragmentation process, where the excitation energy is assumed to be stored in compression and expansion effects. (orig.)

  19. Nonlinear Modeling of Autoclaved Aerated Concrete Masonry Wall Strengthened using Ferrocement Sandwich Structure

    KAUST Repository

    M., Abdel-Mooty

    2011-01-01

    Autoclaved Aerated Concrete (AAC) block are used mainly as non-load-bearing walls that provide heat insulation. This results in considerable saving in cooling energy particularly in hot desert environment with large variation of daily and seasonal temperatures. However, due to the relatively low strength there use load bearing walls is limited to single storey and low-rise construction. A system to enhance the strength of the AAC masonry wall in resisting both inplane vertical and combined vertical and lateral loads using ferrocement technology is proposed in this research. The proposed system significantly enhances the load carrying capacity and stiffness of the AAC wall without affecting its insulation characteristics. Ferrocement is made of cement mortar reinforced with closely spaced wire mesh. Full scale wall specimens with height of 2100mm and width of 1820mm were tested with different configuration of ferrocement. A finite elementmodel is developed and verified against the experimentalwork. The results of the finite element model correlates well with the experimental results.

  20. Study of 24Mg(18O,16O)26Mg reaction at Esub(180)=50MeV including scattering in entrance and exit channel

    International Nuclear Information System (INIS)

    Bernas, M.; Pougheon, F.; Roy-Stephan, M.; Berg, G.P.A.; Kernforschungsanlage Juelich G.m.b.H.; Berthier, B.; Le Fevre, J.P.; Wildenthal, B.H.

    1980-01-01

    Cross section angular distributions of 24 Mg( 18 O, 16 O) 26 Mg reaction at 50 MeV incident energy leading to the first four excited states in 26 Mg and the elastic and inelastic scattering for 18 O + 24 Mg at 50 MeV and 16 O + 26 Mg at 56 MeV have been measured in order to investigate the reaction mechanism of the two-nucleon transfer reaction including the analysis of incident and exit channels. The measured angular distributions were analyzed in the framework of the EFR-DWBA. Two neutron transfer amplitudes were determined using the 2s-1d shell model amplitudes calculated by Chung and Wildenthal. The large experimental cross section in contrast to the smallness of the direct transfer amplitude and the peculiar shape of the measured angular distribution of the lowest 2 1 + state suggests that this level is mainly excited by two-step processes. It is shown that a CCBA calculation describes successfully the angular distributions of the ground state and the 2 1 + state in 26 Mg

  1. Mass spectra and fusion cross sections for 20Ne+24Mg interaction at 55 and 85 MeV

    International Nuclear Information System (INIS)

    Grotowski, K.; Belery, P.; Delbar, T.; El Masri, Y.; Gregoire, G.; Janssens, R.; Vervier, J.; Paic, G.; Albinska, M.; Albinski, J.; Kopta, S.; Kozik, T.; Planeta, R.

    1981-01-01

    Inclusive γ spectra from the 20 Ne+ 24 Mg interaction have been measured using 55- and 85-MeV 20 Ne ions. The identification of γ lines allows the determination of mass spectra in the region 12< or =A< or =43. Experimental results are compared with statistical model calculations. The total reaction and fusion cross sections are extracted. Cross sections for inelastic scattering, few nucleon transfers, and deep inelastic scattering are estimated

  2. Chemical modification of L-glutamine to alpha-amino glutarimide on autoclaving facilitates Agrobacterium infection of host and non-host plants: A new use of a known compound

    Directory of Open Access Journals (Sweden)

    Das Pralay

    2011-05-01

    Full Text Available Abstract Background Accidental autoclaving of L-glutamine was found to facilitate the Agrobacterium infection of a non host plant like tea in an earlier study. In the present communication, we elucidate the structural changes in L-glutamine due to autoclaving and also confirm the role of heat transformed L-glutamine in Agrobacterium mediated genetic transformation of host/non host plants. Results When autoclaved at 121°C and 15 psi for 20 or 40 min, L-glutamine was structurally modified into 5-oxo proline and 3-amino glutarimide (α-amino glutarimide, respectively. Of the two autoclaved products, only α-amino glutarimide facilitated Agrobacterium infection of a number of resistant to susceptible plants. However, the compound did not have any vir gene inducing property. Conclusions We report a one pot autoclave process for the synthesis of 5-oxo proline and α-amino glutarimide from L-glutamine. Xenobiotic detoxifying property of α-amino glutarimide is also proposed.

  3. Use of urinary biomarkers to characterize occupational exposure to BTEX in healthcare waste autoclave operators.

    Science.gov (United States)

    Rafiee, Ata; Delgado-Saborit, Juana Maria; Gordi, Elham; Quémerais, Bernadette; Kazemi Moghadam, Vahid; Lu, Wenjing; Hashemi, Fallah; Hoseini, Mohammad

    2018-08-01

    Urinary benzene, toluene, ethylbenzene, and xylenes (BTEX) can be used as a reliable biomarker of exposure to these pollutants. This study was aimed to investigate the urinary BTEX concentration in operators of healthcare waste (HCW) autoclaves. This cross-sectional study was conducted in selected hospitals in Tehran, Iran between April and June 2017. Twenty operators (as the case group) and twenty control subjects were enrolled in the study. Personal urine samples were collected at the beginning and end of the work shift. Urinary BTEX were measured by a headspace gas chromatography-mass spectrometry (GC/MS). A detailed questionnaire was used to gather information from subjects. Results showed that the median of urinary benzene, toluene, ethylbenzene, m-p xylene, and o-xylene levels in the exposed group were 3.26, 3.36, 0.84, 3.94 and 4.48 μg/L, respectively. With the exception of ethylbenzene, subjects in the exposed group had significantly higher urinary BTEX levels than control group (p autoclave used were also identified as predictors of urinary BTEX concentrations. The healthcare waste treatment autoclaves can be considered as a significant BTEX exposure source for operators working with these treatment facilities. The appropriate personal protection equipment and control measures capable in reducing BTEX exposure should be provided to HCW workers to reduce their exposures to BTEX. Copyright © 2018 Elsevier B.V. All rights reserved.

  4. Relationship of pressure to temperature rise in overfilled cylinders

    International Nuclear Information System (INIS)

    Barber, E.J.

    1979-01-01

    Mild steel pressure vessels containing uranium hexafluoride are heated in 96-inch diameter autoclaves to allow the feed material to enter the gaseous diffusion process equipment for enrichment in the uranium 235 isotope. For purposes of safety analysis it is necessary to establish the ability of the instrumentation to shut off the steam supply to the autoclave prior to cylinder rupture if the cylinder has been overfilled. To make this determination requires estimates of the rate of change of pressure with respect to change of temperature at constant volume as a function of the temperature at which the ullage disappears. The paper presents the calculations for the estimation of this rate of change for liquid uranium hexafluoride using the ratio of the coefficients of expansion and compressibility using empirical liquid density data and the Eyring equation of state for liquids. 5 figs. (MB)

  5. Autoclaved Tumor Bone for Skeletal Reconstruction in Paediatric Patients: A Low Cost Alternative in Developing Countries

    Directory of Open Access Journals (Sweden)

    Masood Umer

    2013-01-01

    Full Text Available We reviewed in this series forty patients of pediatric age who underwent resection for malignant tumors of musculoskeletal system followed by biological reconstruction. Our surgical procedure for reconstruction included (1 wide en bloc resection of the tumor; (2 curettage of tumor from the resected bone; (3 autoclaving for 8 minutes (4 bone grafting from the fibula (both vascularized and nonvascularized fibular grafts used; (5 reimplantation of the autoclaved bone into the host bone defect and fixation with plates. Functional evaluation was done using MSTS scoring system. At final followup of at least 18 months (mean 29.2 months, 31 patients had recovered without any complications. Thirty-eight patients successfully achieved a solid bony union between the graft and recipient bone. Three patients had surgical site infection. They were managed with wound debridement and flap coverage of the defect. Local recurrence and nonunion occurred in two patients each. One patient underwent disarticulation at hip due to extensive local disease and one died of metastasis. For patients with non-union, revision procedure with bone graft and compression plates was successfully used. The use of autoclaved tumor grafts provides a limb salvage option that is inexpensive and independent of external resources and is a viable option for musculoskeletal tumor management in developing countries.

  6. Application of powder metallurgy to an advanced-temperature nickel-base alloy, NASA-TRW 6-A

    Science.gov (United States)

    Freche, J. C.; Ashbrook, R. L.; Waters, W. J.

    1971-01-01

    Bar stock of the NASA-TRW 6-A alloy was made by prealloyed powder techniques and its properties evaluated over a range of temperatures. Room temperature ultimate tensile strength was 1894 MN/sq m (274 500 psi). The as-extruded powder product showed substantial improvements in strength over the cast alloy up to 649 C (1200 F) and superplasticity at 1093 C (2000 F). Both conventional and autoclave heat treatments were applied to the extruded powder product. The conventional heat treatment was effective in increasing rupture life at 649 and 704 C (1200 and 1300 F); the autoclave heat treatment, at 760 and 816 C (1400 and 1500 F).

  7. Neutron-Neutron effective range from a comparison of n-n and n-p quasi-free scattering at 24 MeV

    International Nuclear Information System (INIS)

    Witsch, W. von; Gomez Moreno, B.; Rosenstock, W.; Franke, R.; Steinheuer, B.

    1980-01-01

    Neutron-neutron and neutron-proton quasi-free scattering have been measured at Esub(n) = 24 MeV the d + n reaction to deduce the n-n effective range from a comparison of relative cross sections, reducing considerably experimental as well as theoretical uncertainties. A Monte Carlo analysis with exact three-body calculations yields rsub(nn) = 2.65 +- 0.18 fm. (orig.)

  8. Decay of a Jπ=36+ Resonance in the 24Mg+24Mg Reaction

    International Nuclear Information System (INIS)

    Salsac, M.-D.; Haas, F.; Courtin, S.

    2005-01-01

    For the 24 Mg+ 24 Mg reaction, striking narrow and correlated resonance structures have been observed previously in the excitation functions of the elastic and low-lying channels. In our study we have decided to focus on the resonance at E C M =45.7 MeV, which is known to have J π =36 + . Despite the very high excitation energy(∼60 MeV) in the 48 Cr composite system, this resonance has a narrow total width of 170 keV. To determine precisely which states in the inelastic 24 Mg channels carry away the resonance flux, an experiment, on the 24 Mg + 24 Mg reaction at energies On and OFF resonance, has been performed at the Legnaro Tandem accelerator using the Prisma fragment spectrometer associated with the CLARA γ array

  9. Rapid synthesis of binary α-NiS–β-NiS by microwave autoclave for rechargeable lithium batteries

    International Nuclear Information System (INIS)

    Idris, Nurul Hayati; Rahman, Md Mokhlesur; Chou, Shu-Lei; Wang Jiazhao; Wexler, David; Liu, Hua-Kun

    2011-01-01

    Highlights: ► NiS has been synthesized by a rapid, one-pot, hydrothermal microwave autoclave method. ► The α-NiS–β-NiS sample synthesized at 160 °C yielded good electrochemical performance in terms of high reversible capacity (320 mAh g −1 at 0.1C up to 100 cycles). ► At high rates, the sample operated at a good fraction of its capacity. - Abstract: To reduce the reaction time, electrical energy consumption, and cost, binary α-NiS–β-NiS has been synthesized by a rapid, one-pot, hydrothermal autoclave microwave method within 15 min at temperatures of 160–180 °C. The microstructure and morphology of the α-NiS–β-NiS products were characterized by means of X-ray diffraction (XRD), field emission scanning electron microscopy (FE-SEM), and transmission electron microscopy (TEM). At 140 °C, pure hexagonal NiAs-type α-NiS phase was identified from the XRD patterns. With increasing reaction temperature (160–180 °C), the XRD evidence indicates that an increasing fraction of rhombohedral millerite-like β-NiS is formed as a secondary phase. The α-NiS–β-NiS sample synthesized at 160 °C yielded good electrochemical performance in term of high reversible capacity (320 mAh g −1 at 0.1C up to 100 cycles). Even at high rates, the sample operated at a good fraction of its capacity. The likely contributing factor to the superior electrochemical performance of the α-NiS–β-NiS sample could be related to the improved morphology. TEM imaging confirmed that needle-like protrusions connect the clusters of α-NiS particles, and the individual protrusions indicated a very high surface area including folded sheet morphology, which helps to dissipate the surface accumulation of Li + ions and facilitate rapid mobility. These factors help to enhance the amount of lithium intercalated within the material.

  10. Reaction rate of 24Mg(p,γ)25Al

    International Nuclear Information System (INIS)

    Powell, D.C.; Iliadis, C.; Champagne, A.E.; Grossmann, C.A.; Hale, S.E.; Hansper, V.Y.; McLean, L.K.

    1999-01-01

    The proton-capture reaction on 24 Mg has been investigated in the bombarding energy range of E p =0.2-1.7 MeV. Resonance properties (strengths, branching ratios and lifetimes) of low-energy resonances have been measured. From the experimental results, accurate proton partial widths, γ-ray partial widths and total widths (Γ p , Γ γ , and Γ) have been deduced. The present experimental information establishes the 24 Mg+p reaction rates over the temperature range T=0.02-2.0 GK with statistical uncertainties of 5% to 21%. Our recommended reaction rates deviate from previous estimates by 18% to 45%. Based on our results, we can rule out the recent suggestion that the total width of the E R =223 keV resonance has a significant influence on the reaction rates. We also discuss several effects that might give rise to systematic uncertainties in the reaction rates. The astrophysical implications for hydrogen burning of 24 Mg at low stellar temperatures are presented

  11. Hydrothermal carbonization of autoclaved municipal solid waste pulp and anaerobically treated pulp digestate

    Science.gov (United States)

    In this study, the autoclaved organic fraction of municipal solid waste pulp (OFMSW) and the digestate from OFMSW pulp after anaerobic digestion (AD) were processed by hydrothermal carbonization (HTC) at 200, 250, and 300 °C for 30 min and 2 h. The focus of this work was to evaluate the potential fo...

  12. Ambient-temperature diffusion and gettering of Pt atoms in GaN with surface defect region under 60Co gamma or MeV electron irradiation

    Science.gov (United States)

    Hou, Ruixiang; Li, Lei; Fang, Xin; Xie, Ziang; Li, Shuti; Song, Weidong; Huang, Rong; Zhang, Jicai; Huang, Zengli; Li, Qiangjie; Xu, Wanjing; Fu, Engang; Qin, G. G.

    2018-01-01

    Generally, the diffusion and gettering of impurities in GaN needs high temperature. Calculated with the ambient-temperature extrapolation value of the high temperature diffusivity of Pt atoms in GaN reported in literature, the time required for Pt atoms diffusing 1 nm in GaN at ambient temperature is about 19 years. Therefore, the ambient-temperature diffusion and gettering of Pt atoms in GaN can hardly be observed. In this work, the ambient-temperature diffusion and gettering of Pt atoms in GaN is reported for the first time. It is demonstrated by use of secondary ion mass spectroscopy that in the condition of introducing a defect region on the GaN film surface by plasma, and subsequently, irradiated by 60Co gamma-ray or 3 MeV electrons, the ambient-temperature diffusion and gettering of Pt atoms in GaN can be detected. It is more obvious with larger irradiation dose and higher plasma power. With a similar surface defect region, the ambient-temperature diffusion and gettering of Pt atoms in GaN stimulated by 3 MeV electron irradiation is more marked than that stimulated by gamma irradiation. The physical mechanism of ambient-temperature diffusion and gettering of Pt atoms in a GaN film with a surface defect region stimulated by gamma or MeV electron irradiation is discussed.

  13. Indoor Thermal Environment of Temporary Mobile Energy Shelter Houses (MeSHs in South Korea

    Directory of Open Access Journals (Sweden)

    Jeong-Gook Kim

    2015-10-01

    Full Text Available Temporary housing must be developed to support the long-term residence needs of disaster victims. The present study assesses a temporary housing unit, the so-called Mobile Energy Shelter House (MeSH, incorporating the “Korean Dwelling Insulation Standard” in order to reduce energy usage for cooling and heating. To assess energy performance, the characteristics of the indoor thermal environment were measured during the winter and summer seasons. In summer, at maximum insolation, the outdoor temperature was 37.6 °C and the indoor temperature of the MeSH ranged from 18 to 24 °C when the cooling system was not used. Conversely, during winter, the average outdoor temperature was −11.3 °C and the indoor temperature ranged from 16.09 to 20.63 °C when a temperature-controlled floor-heating was installed. Furthermore, the Predicted Mean Vote (PMV was adopted to determine whether the ISO 7730 comfort criterion (i.e., PMV range from −0.5 to +0.5 was achieved. Based on the calculations presented here, PMV in summer ranged from −1.21 to +1.07 and that in winter ranged from −0.08 to −0.85, suggesting that the thermal environment is not always comfortable for occupants in either summer or winter. Nevertheless, the ISO comfort criterion can be achieved through varying air velocity in summer and changing clothing characteristics in winter. A comparison between yearly energy demand of existing characteristic temporary housing (Shelter House and the MeSH modules used in this study was performed. The simulation results show a 60% difference in energy demand between MeSH and existing temporary housing shelter houses.

  14. Cross sections measurements for the forward elastic scattering of 13 MeV 6,7 Li and 24 MeV 16 O by 9 Be, 12 C, 16 O and 28 Si

    International Nuclear Information System (INIS)

    Liendo, J.A.; Gonzalez, A.C.; Fletcher, N.R.; Caussyn, D.D.

    2001-01-01

    Full text: Absolute elastic cross sections have been measured for targets of 9 Be, 12 C 16 O, 28 Si and 197 Au being bombarded by beams of 13 MeV 6 7 Li and 24 MeV 16 O. The relevant yields were collected simultaneously at 12.450, 16.450, 20.450 and 280. The confidence of a forward elastic scattering method proposed previously to carry out multi-elemental analysis of evaporated liquid samples depends on the precision and accuracy of the cross sections reported in this work.The 24 MeV 16 0 + 197 Au reaction was used to determine the detector solid angles with uncertainties of approximately 3%. Some of the 16 O-beam reactions Some of the 16 O beam reactions have been shown to be consistent with the Rutherford formula predictions at several angles. This allowed us to obtain target thickness independent cross sections for the lithium beam initiated reactions with uncertainties close to 7%. In general, the 6 7 Li-beam reaction cross sections were found not to be consistent with the Coulomb scattering formula. In order to test the internal consistency of our measured cross sections, they were used to determine the elemental densities of several selected targets containing beryllium, carbon, oxygen and silicon. These targets were bombarded with the same beam types and energies used to measure the cross sections and, for every element of interest contained in each target, elemental density values were obtained at some of the scattering angles quoted above. Agreements between some of our results and those of a previous work support the validity of our measurements. (Author)

  15. The Corrosion Rate Measurement of Inconel 690 on High Temperature andPressure by Using CMS100

    International Nuclear Information System (INIS)

    Sriyono; Febrianto

    2000-01-01

    The corrosion rate measurement of Inconel 690 on high temperature andpressure had been done. By using an Autoclave, pressure and temperature canbe simulated. The environment of this experiment is 0.1 ppm of chloridesolution, which permit to dissolved in secondary cooling of steam generator.The corrosion rate measurement was done on temperature between 150 o C and230 o C with step 10 o C. Pressure experiment is the pressure, which occurredin Autoclave. Corrosion rate is measured by CMS100. From the Tafel analysis,corrosion rate of Inconel 690 linearity increased from 6.548 x 10 -5 mpy to4.331 x 10 -4 mpy. It concludes that Inconel 690 is resist on corrosionenvironment, so it's most using on the fabrication of steam generator tubeson the advanced power plant. (author)

  16. CHOICE THEORY OF CREEP DEFORMATION FOR EVALUATION OF LONG FINE-GRAINED AUTOCLAVED AERATED CONCRETE IN VIEW OF FACTORS CARBONIZATION

    Directory of Open Access Journals (Sweden)

    D. K-S. Bataev

    2015-01-01

    Full Text Available Experimental data on the effect of the age of autoclaved aerated concrete with and without carbonation factor to change its physical and mechanical characteristics, as well as by the amount of creep deformation and degree of reversibility. It was found that the solution of applied problems creep theory for structures of autoclaved aerated concrete, in accordance with their carbonation from the effects of atmospheric carbon dioxide, it is necessary to use the theory of elastic-creeping body on the basis of function creep measures in the form proposed by prof. S.V. Alexandrovsky. 

  17. Pressure-accelerated azide-alkyne cycloaddition: micro capillary versus autoclave reactor performance.

    Science.gov (United States)

    Borukhova, Svetlana; Seeger, Andreas D; Noël, Timothy; Wang, Qi; Busch, Markus; Hessel, Volker

    2015-02-01

    Pressure effects on regioselectivity and yield of cycloaddition reactions have been shown to exist. Nevertheless, high pressure synthetic applications with subsequent benefits in the production of natural products are limited by the general availability of the equipment. In addition, the virtues and limitations of microflow equipment under standard conditions are well established. Herein, we apply novel-process-window (NPWs) principles, such as intensification of intrinsic kinetics of a reaction using high temperature, pressure, and concentration, on azide-alkyne cycloaddition towards synthesis of Rufinamide precursor. We applied three main activation methods (i.e., uncatalyzed batch, uncatalyzed flow, and catalyzed flow) on uncatalyzed and catalyzed azide-alkyne cycloaddition. We compare the performance of two reactors, a specialized autoclave batch reactor for high-pressure operation up to 1800 bar and a capillary flow reactor (up to 400 bar). A differentiated and comprehensive picture is given for the two reactors and the three methods of activation. Reaction speedup and consequent increases in space-time yields is achieved, while the process window for favorable operation to selectively produce Rufinamide precursor in good yields is widened. The best conditions thus determined are applied to several azide-alkyne cycloadditions to widen the scope of the presented methodology. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. 24 CFR 103.10 - What can I do if I believe someone is discriminating against me in the sale, rental, finance, or...

    Science.gov (United States)

    2010-04-01

    ... 24 Housing and Urban Development 1 2010-04-01 2010-04-01 false What can I do if I believe someone is discriminating against me in the sale, rental, finance, or advertisement of housing? 103.10 Section 103.10 Housing and Urban Development Regulations Relating to Housing and Urban Development OFFICE OF ASSISTANT SECRETARY FOR EQUAL OPPORTUNITY,...

  19. Conduction and transport numbers in metacomposites MeWO4 · WO3 (Me = Ca, Sr, Ba)

    International Nuclear Information System (INIS)

    Nejman, A.Ya.; Pestereva, N.N.; Sharafutdinov, A.R.; Kostikov, Yu.P.

    2005-01-01

    The conductivity and transfer numbers of charge carriers for composites in the MeWO 4 -WO 3 (Me = Ca, Sr, Ba) systems are studied as a function of the temperature and the activity of oxygen in a gas phase. The transfer numbers are determined by the emf method and are estimated from dependences of conductivity on the activity of oxygen in a gas phase. The deficiencies of the given procedure as applied to investigation of properties of composite phases are analyzed. The materials under study are classified as metacomposites. The concentration intervals of the ionic, mixed, and electronic conductivities are determined. The conductivity of (100-x)MeWO 4 · xWO 3 composites is predominantly ionic at x ≤ 10 (Me = Ca), x ≤ 60 (Me = Sr), and x ≤ 45 (Me = Ba). The obtained data are explained in the framework of a model that represents a composite as a distributed matrix system where a film of surface phase MeW-s with a high mobility of oxygen ions plays the role of a connected matrix. It is presumed that the surface phase MeW-s possesses double-sided surface activity (α MeW-s ≤ α WO 3 , α MeWO 4 ) and a higher mobility with respect to MeWO 4 and WO 3 . The discovered anomalies of dependences σ O 2- (T) and partial conductivities σ O 2- , σ el (T) are explained by a change in the stoichiometry, morphology, and the degree of tie-up of surface phase MeW-s caused by a change in the temperature and composition of composites [ru

  20. Evidence for two narrow pp resonances at 2020 MeV and 2200 MeV

    CERN Document Server

    Benkheiri, P; Bouquet, B; Briandet, P; D'Almagne, B; Dang-Vu, C; De Rosny, G; Eisenstein, B I; Ferrer, A; Fleury, P; Grossetête, B; Irwin, G; Jacholkowski, A; Lahellec, A; Nguyen, H; Petroff, P; Richard, F; Rivet, P; Roudeau, P; Rougé, A; Rumpf, M; Six, J; Thénard, J M; Treille, D; Volte, A; Yaffe, D; Yiou, T P; Yoshida, H

    1977-01-01

    From the study of the reaction pi /sup -/p to p/sub F/pp pi /sup -/ using a fast proton (p/sub F/) trigger device in the CERN Omega spectrometer, the authors find evidence for two narrow pp states produced mainly in association with a Delta degrees (1232) and a N degrees (1520). The statistical significance of each peak is greater than 6 standard deviations. Masses and natural widths of these resonances are respectively M/sub 1/=2020+or-3 MeV, Gamma /sub 1 /=24+or-12 MeV and M/sub 2/=2204+or-5 MeV, Gamma /sub 2/=16/sub -16 //sup +20/ MeV. The data are consistent with a small production of the narrow approximately 1935 MeV resonance already reported. Production cross sections for these new pp resonances are given. (8 refs).

  1. Autoclave reduction of jarosites and other metal sulfates : a new approach to major waste problems

    NARCIS (Netherlands)

    Hage, J.T.L.

    1999-01-01

    Industrial jarosite is a waste product of the zinc industry. It is considered a serious environmental problem, due to the quantity produced and the mobile hazardous metals it contains. Over 50 million tons are already stored worldwide. The jarosite sludge autoclave treatment process described in

  2. Validation of Autoclave Protocols for Successful Decontamination of Category A Medical Waste Generated from Care of Patients with Serious Communicable Diseases.

    Science.gov (United States)

    Garibaldi, Brian T; Reimers, Mallory; Ernst, Neysa; Bova, Gregory; Nowakowski, Elaine; Bukowski, James; Ellis, Brandon C; Smith, Chris; Sauer, Lauren; Dionne, Kim; Carroll, Karen C; Maragakis, Lisa L; Parrish, Nicole M

    2017-02-01

    In response to the Ebola outbreak in 2014, many hospitals designated specific areas to care for patients with Ebola and other highly infectious diseases. The safe handling of category A infectious substances is a unique challenge in this environment. One solution is on-site waste treatment with a steam sterilizer or autoclave. The Johns Hopkins Hospital (JHH) installed two pass-through autoclaves in its biocontainment unit (BCU). The JHH BCU and The Johns Hopkins biosafety level 3 (BSL-3) clinical microbiology laboratory designed and validated waste-handling protocols with simulated patient trash to ensure adequate sterilization. The results of the validation process revealed that autoclave factory default settings are potentially ineffective for certain types of medical waste and highlighted the critical role of waste packaging in successful sterilization. The lessons learned from the JHH validation process can inform the design of waste management protocols to ensure effective treatment of highly infectious medical waste. Copyright © 2017 American Society for Microbiology.

  3. Mössbauer study of oxide films of Fe-, Sn-, Cr- doped zirconium alloys during corrosion in autoclave

    Energy Technology Data Exchange (ETDEWEB)

    Filippov, V. P., E-mail: vpfilippov@mephi.ru; Bateev, A. B.; Lauer, Yu. A. [National Research Nuclear University “MEPhI” (Moscow Engineering Physics Institute) (Russian Federation)

    2016-12-15

    Mössbauer investigations were used to compare iron atom states in oxide films of binary Zr-Fe, ternary Zr-Fe-Cu and quaternary Zr-Fe-Cr-Sn alloys. Oxide films are received in an autoclave at a temperature of 350–360 °C and at pressure of 16.8 MPa. The corrosion process decomposes the intermetallic precipitates in alloys and forms metallic iron with inclusions of chromium atoms α–Fe(Cr), α–Fe(Cu), α–Fe {sub 2}O{sub 3} and Fe {sub 3}O{sub 4} compounds. Some iron ions are formed in divalent and in trivalent paramagnetic states. The additional doping influences on corrosion kinetics and concentration of iron compounds and phases formed in oxide films. It was shown the correlation between concentration of iron in different chemical states and corrosion resistance of alloys.

  4. Thermal properties of Poly(ethylene terephthalate) recovered from municipal solid waste by steam autoclaving

    Science.gov (United States)

    The goal of this study was to evaluate the effects of steam autoclaving on the properties of PET, data which could ultimately be applied to determine the most likely end use of this potentially huge waste stream. Through the course of the study it was determined that stretch blow molding in bottle ...

  5. Surface temperature measurements for ion-bombarded Si and GaAs at 1.0 to 2.0 MeV

    International Nuclear Information System (INIS)

    Lowe, L.F.; Kennedy, J.K.; Davies, D.E.; Deane, M.L.; Eyges, L.J.

    1975-01-01

    Surface temperatures of ion-bombarded silicon and gallium arsenide have been measured using an infrared detector. Ion beams of N + , N + 2 , O + , O + 2 , C + , CO + , and H + were used at energies from 1--2.0 MeV and at current densities up to 12 μAcenter-dotcm/sup -2/. No temperature dependence was found on ion species, energy, or current. The change in temperature depended only on beam power, target material, and sample mounting technique. With proper mounting temperature increases of 20 degreeC for silicon and 65 degreeC for gallium arsenide were observed for a beam power density of 1.0 Wcenter-dotcm/sup -2/

  6. Kinetics of passivation of a nickel-base alloy in high temperature water

    Energy Technology Data Exchange (ETDEWEB)

    Machet, A. [Laboratoire de Physico-Chimie des Surfaces, CNRS-ENSCP (UMR 7045), Ecole Nationale Superieure de Chimie de Paris, Universite Pierre et Marie Curie, F-75231 Paris cedex 05 (France)]|[Framatome ANP, Tour AREVA, F-92084 Paris-la-Defense (France); Galtayries, A.; Zanna, S.; Marcus, P. [Laboratoire de Physico-Chimie des Surfaces, CNRS-ENSCP (UMR 7045), Ecole Nationale Superieure de Chimie de Paris, Universite Pierre et Marie Curie, F-75231 Paris cedex 05 (France); Jolivet, P.; Scott, P. [Framatome ANP, Tour AREVA, F-92084 Paris-la-Defense (France); Foucault, M.; Combrade, P. [Framatome ANP, Centre Technique, F-71205 Le Creusot (France)

    2004-07-01

    The kinetics of passivation and the composition of the surface oxide layer, in high temperature and high pressure water, of a nickel-chromium-iron alloy (Alloy 600) have been investigated by X-ray Photoelectron Spectroscopy (XPS). The samples have been exposed for short (0.4 - 8.2 min) and longer (0 - 400 hours) time periods to high temperature (325 deg. C) and high pressure water (containing boron and lithium) under controlled hydrogen pressure. The experiments were performed in two types of autoclaves: a novel autoclave dedicated to short time periods and a classic static autoclave for the longer exposures. In the initial stage of passivation, a continuous ultra-thin layer of chromium oxide (Cr{sub 2}O{sub 3}) is rapidly formed on the surface with an external layer of chromium hydroxide. For longer times of passivation, the oxide layer is in a duplex form with an internal chromium oxide layer and an external layer of nickel hydroxide. The growth of the internal Cr{sub 2}O{sub 3} oxide layer has been fitted by three classical models (parabolic, logarithmic and inverse logarithmic laws) for the short passivation times, and the growth curves have been extrapolated to longer passivation periods. The comparison with the experimental results reveals that the kinetics of passivation of Alloy 600 in high temperature and high pressure water, for passivation times up to 400 hours, is well fitted by a logarithmic growth law. (authors)

  7. Kinetics of passivation of a nickel-base alloy in high temperature water

    International Nuclear Information System (INIS)

    Machet, A.; Galtayries, A.; Zanna, S.; Marcus, P.; Jolivet, P.; Scott, P.; Foucault, M.; Combrade, P.

    2004-01-01

    The kinetics of passivation and the composition of the surface oxide layer, in high temperature and high pressure water, of a nickel-chromium-iron alloy (Alloy 600) have been investigated by X-ray Photoelectron Spectroscopy (XPS). The samples have been exposed for short (0.4 - 8.2 min) and longer (0 - 400 hours) time periods to high temperature (325 deg. C) and high pressure water (containing boron and lithium) under controlled hydrogen pressure. The experiments were performed in two types of autoclaves: a novel autoclave dedicated to short time periods and a classic static autoclave for the longer exposures. In the initial stage of passivation, a continuous ultra-thin layer of chromium oxide (Cr 2 O 3 ) is rapidly formed on the surface with an external layer of chromium hydroxide. For longer times of passivation, the oxide layer is in a duplex form with an internal chromium oxide layer and an external layer of nickel hydroxide. The growth of the internal Cr 2 O 3 oxide layer has been fitted by three classical models (parabolic, logarithmic and inverse logarithmic laws) for the short passivation times, and the growth curves have been extrapolated to longer passivation periods. The comparison with the experimental results reveals that the kinetics of passivation of Alloy 600 in high temperature and high pressure water, for passivation times up to 400 hours, is well fitted by a logarithmic growth law. (authors)

  8. Release of bound residues of atrazine from soils through autoclaving and gamma radiation sterilization

    International Nuclear Information System (INIS)

    Nakagawa, L.E.; Andréa, M.M.

    1997-01-01

    The sterilization methods are particularly important to study the influence of microorganisms on the pesticide dissipation in soils. This study, conducted in the laboratories of the Instituto Biológico of São Paulo in august 1996, tested the influence of two methods of soil sterilization - moist heat (autoclaving) and γ radiation - on the release of nonextractable or bound residues. It was studied, as example, bound residues of the herbicide atrazine in two types of soil (gley humic and dark red latosol). In the soil samples submitted to the moist heat sterilization, the recovery of the previously bound residues as reextractable residues was 5.6 and 5.9 times higher than in the control soils, not submitted to any sterilization process. Therefore, the method itself released the residues, indicating that the autoclaving is not the most appropriate method for studies on the influence of microorganisms on the release of bound residues. Otherwise, the γ radiation did not modify the residues recovery when compared to the controls. (author) [pt

  9. Diseño de un biorreactor a partir de un autoclave en deshuso

    Directory of Open Access Journals (Sweden)

    Teresa Salazar-Rojas

    2014-06-01

    Este artículo detalla el proceso de construcción de un prototipo de biorreactor piloto, con todas las características necesarias para su funcionalidad, partiendo de una autoclave obsoleta. Con el fin de dar ejemplo de cómo se puede extender la vida útil de un material de desecho y, además, minimizar costos al obtener un equipo 100% funcional.

  10. Design and deployment of autoclave pressure vessels for the portable deep-sea drill rig MeBo (Meeresboden-Bohrgerät)

    Science.gov (United States)

    Pape, Thomas; Hohnberg, Hans-Jürgen; Wunsch, David; Anders, Erik; Freudenthal, Tim; Huhn, Katrin; Bohrmann, Gerhard

    2017-11-01

    Pressure barrels for sampling and preservation of submarine sediments under in situ pressure with the robotic sea-floor drill rig MeBo (Meeresboden-Bohrgerät) housed at the MARUM (Bremen, Germany) were developed. Deployments of the so-called MDP (MeBo pressure vessel) during two offshore expeditions off New Zealand and off Spitsbergen, Norway, resulted in the recovery of sediment cores with pressure stages equaling in situ hydrostatic pressure. While initially designed for the quantification of gas and gas-hydrate contents in submarine sediments, the MDP also allows for analysis of the sediments under in situ pressure with methods typically applied by researchers from other scientific fields (geotechnics, sedimentology, microbiology, etc.). Here we report on the design and operational procedure of the MDP and demonstrate full functionality by presenting the first results from pressure-core degassing and molecular gas analysis.

  11. The effect of multiple autoclave cycles on the surface of rotary nickel-titanium endodontic files: An in vitro atomic force microscopy investigation.

    Science.gov (United States)

    Nair, Ashish Shashikant; Tilakchand, Mahima; Naik, Balaram Damodar

    2015-01-01

    To observe and study the effect of multiple autoclave sterilization cycles, on the surface of nickel-titanium (NiTi) files. The file used for this study was the Mtwo file (VDW) and ProTaper (Dentsply). The apical 5 mm of the files were attached to a silicon wafer and subjected to autoclave cycles under standardized conditions. They were scanned with an AFM after 1, 5, and 10 cycles. The unsterilized files were used as control, before start of the study. Three vertical topographic parameters namely maximum height (MH), root mean square (RMS) of surface roughness, and arithmetic mean roughness (AMR)were measured with the atomic force microscope (AFM). Analysis of variance along with Tukey's test was used to test the differences. The vertical topographic parameters were higher for both the files, right after the first cycle, when compared with the control (P autoclave cycles, a fact that should be kept in mind during their reuse.

  12. Effect of Dephytinization by Fermentation and Hydrothermal Autoclaving Treatments on the Antioxidant Activity, Dietary Fiber, and Phenolic Content of Oat Bran.

    Science.gov (United States)

    Özkaya, H; Özkaya, B; Duman, B; Turksoy, S

    2017-07-19

    Fermentation and hydrothermal methods were tested to reduce the phytic acid (PA) content of oat bran, and the effects of these methods on the dietary fiber (DF) and total phenolic (TP) contents as well as the antioxidant activity (AA) were also investigated. Fermentation with 6% yeast and for 6 h resulted in 88.2% reduction in PA content, while it only resulted in 32.5% reduction in the sample incubated for 6 h without yeast addition. The PA loss in autoclaved oat bran sample (1.5 h, pH 4.0) was 95.2% while it was 41.8% at most in the sample autoclaved without pH adjustment. In both methods, soluble, insoluble, and total DF contents of samples were remarkably higher than the control samples. Also for TP in the oat bran samples, both processes led to 17% and 39% increases, respectively, while AA values were 8% and 15%, respectively. Among all samples, the autoclaving process resulted in the lowest PA and the greatest amount of bioactive compounds.

  13. Giant quadrupole resonance in 24Mg, 27Al, and 28Si

    International Nuclear Information System (INIS)

    Youngblood, D.H.; Rozsa, C.M.; Moss, J.M.; Brown, D.R.; Bronson, J.D.

    1977-01-01

    The giant-resonance region of 24 Mg, 27 Al, and 28 Si was studied by inelastic scattering of 126-MeV α particles. In contrast to results at 96 MeV, considerable clustering of E2 strength was observed for 27 Al at E/sub x/ approx. 20.1 MeV with GAMMA approx. 7.6 MeV exhausting about 35% of the E2 energy weighted sum rule. E2 strength was also located in 24 Mg in two clusters of states at E-bar/sub x/ approx. 18.2, 24.4 MeV; however, contributions from other multipoles cannot be neglected. In 28 Si a multipeaked group was observed at E/sub x/ approx. 19.4 MeV with GAMMA approx. 4 MeV but no L assignment was made. The energy dependence of the cross section for the giant quadrupole resonance was found to be consistent with distorted-wave Born approximation predictions

  14. Development of Colletotrichum gloeosporioides isolated from green pepper in different culture media, temperatures, and light regimes

    Directory of Open Access Journals (Sweden)

    Mello Alexandre Furtado Silveira

    2004-01-01

    Full Text Available Control of anthracnose in green pepper involves the use of resistant varieties and/or fungicides. The selection of varieties and efficient products demands great amounts of conidia as inoculum. It is thus necessary to optimize the production of Colletotrichum gloeosporioides conidia in the laboratory, establishing the best conditions for fungus development. The present study aimed at determining the most favorable culture media, temperature, and light conditions for the production of fungus inoculum. The fungus was isolated from green pepper fruits (Capsicum annuum L. and transferred to four culture media (PDA, oat, filtered pepper extract, and autoclaved pepper extract, under different temperatures (15, 20, 25, 30, and 35ºC and light conditions (24h dark, and 24h light. Colony growth was evaluated after 7 and 12 days of incubation. No differences were found between the culture media. However, the greatest number of conidia was obtained from colonies grown in oat medium at 25ºC. Temperatures of 20 and 25ºC were the most favorable for colony growth and sporulation. Higher sporulation was obtained under incubation in constant light. Cultivation of C. gloeosporioides in oat medium, at 25ºC, and constant light is recommended.

  15. Study of the angular correlations of light charged particles for the reaction {sup 35}CI (260 MeV) + {sup 24}Mg; Etude des correlations angulaires de particules legeres chargees dans la reaction {sup 35}CI (260 MeV) + {sup 24}Mg

    Energy Technology Data Exchange (ETDEWEB)

    Mahboub, D.

    1996-10-30

    This work is focussed on the investigation of deformed nuclei. The asymmetric fusion-fission of light heavy-ions (A {<=}60) with a high excitation energy (T {approx} 4 MeV) had lead to a large deformation of the compound nucleus at the scission point. The angular correlations between light particles (LP) and their emitting fragments has been used to probe the deformation of nucleus. Exclusive measurements were performed for the {sup 35}Cl (260 MeV) + {sup 24}Mg system leading to the {sup 59}Cu compound nucleus (CN). The comparison between the energy spectra of LP`s and a statistical calculation carried out by a Monte-Carlo code CASCADE has suggested a deformation of 1.3 (for an oblate shape) of the CN within the frame work of fusion-evaporation process. The source velocity spectrum of {alpha} particles and angular correlations of LP`s have showed that pre-scission and pre-equilibrium emissions are negligible in the present reaction. Finally the confrontation of the data with the statistical code GEMINI has pointed out the sequential emission character of the LP`s from the fission fragments. (author). 175 refs.

  16. Comparative catalytic reduction of 4-nitrophenol by polyacrylamide-gold nanocomposite synthesized by hydrothermal autoclaving and conventional heating routes

    Science.gov (United States)

    Salaheldin, Hosam I.

    2017-12-01

    Gold nanoparticles (AuNPs) in polymeric polyacrylamide (PAAm) matrix were synthesized using conventional heating and autoclaving thermal techniques. The synthesized Au/PAAm nanocomposite was characterized using UV-vis spectroscopy and high-resolution transmission electron microscopy. The size of the synthesized particles was approximately 6.37 nm and 8.19 nm with the conventional heating and autoclaving thermal techniques, respectively. Electron diffraction x-ray spectroscopy and the Fourier transformation infrared spectroscopy were used for the composition and elemental studies, which confirmed that the Au metallic atoms were synthesized and embedded within a PAAm matrix via a coordination bond between the carbonyl (-CONH2) group and the metallic NPs. X-ray diffraction confirmed the crystalline nature of the fabricated AuNPs with face centered cubic of nanocrystals. The catalytic activity of the as-prepared Au/PAAm nanocomposite for the reduction of 4-nitrophenol to 4-aminophenol was studied in the presence of sodium borohydrate. The synthesized AuNPs had an effective catalytic activity; the smaller NPs synthesized NPs with the conventional heating technique had a higher reaction kinetic rate in comparation with those synthesized with the autoclaving technique. Therefore, the Au/PAAm nanocomposite can be widely used as an eco-friendly, non-toxic, a fast and cost-effective product to remove versatile organic pollutants such as aromatic nitro compounds.

  17. Cell enlargement of plant tissue explants oscillates with a temperature-compensated period of ca. 24 min

    Science.gov (United States)

    Morre, D. James; Ternes, Philipp; Morre, Dorothy M.

    2002-01-01

    Rate of plant cell enlargement, measured at intervals of 3 min using a sensitive linear transducer, oscillates with a minimum period of about 24 min that parallels the 24-min periodicity observed with the oxidation of NADH by the external plasma membrane NADH oxidase and of single cells measured previously by video-enhanced light microscopy. Also exhibiting 24-min oscillations is the steady-state rate of cell enlargement induced by the addition of the auxin herbicide 2,4-dichlorophenoxyacetic acid (2,4-D) or the natural auxin indole-3-acetic acid (IAA). Immediately following 2,4-D addition, a very complex pattern of oscillations is frequently observed. However, after several hours a dominant 24-min period emerges. The length of the 24-min period is temperature compensated and remains constant at 24 min when measured at 15, 25 or 35 degrees C, despite the fact that the rate of cell enlargement approximately doubles for each 10 degree C rise over this same range of temperatures.

  18. Evaluation of an autoclave resistant anatomic nose model for the testing of nasal swabs.

    Science.gov (United States)

    Bartolitius, Lennart; Frickmann, Hagen; Warnke, Philipp; Ottl, Peter; Podbielski, Andreas

    2014-09-01

    A nose model that allows for the comparison of different modes of sample acquisition as well as of nasal swab systems concerning their suitability to detect defined quantities of intranasal microorganisms, and further for training procedures of medical staff, was evaluated. Based on an imprint of a human nose, a model made of a silicone elastomer was formed. Autoclave stability was assessed. Using an inoculation suspension containing Staphylococcus aureus and Staphylococcus epidermidis, the model was compared with standardized glass plate inoculations. Effects of inoculation time, mode of sampling, and sample storage time were assessed. The model was stable to 20 autoclaving cycles. There were no differences regarding the optimum coverage from the nose and from glass plates. Optimum sampling time was 1 h after inoculation. Storage time after sampling was of minor relevance for the recovery. Rotating the swab around its own axis while circling the nasal cavity resulted in best sampling results. The suitability of the assessed nose model for the comparison of sampling strategies and systems was confirmed. Without disadvantages in comparison with sampling from standardized glass plates, the model allows for the assessment of a correct sampling technique due to its anatomically correct shape.

  19. Autoclaved aerated concrete : shaping the evolution of residential construction in the United States.

    OpenAIRE

    Bukoski, Steven C.

    1998-01-01

    CIVINS (Civilian Institutions) Thesis document Precast Autoclaved Aerated Concrete (AAC) is a proven construction material used in Europe for over 70 years. Introduced to the United States in 1990, construction thus far is limited to commercial and custom borne applications. Premium benefits include energy efficiency and resistance to natural disaster and pests. Despite being the leading residential construction material in Europe and Japan, lumber is the leading material of choice in the ...

  20. Effect of autoclaving on the surfaces of TiN -coated and conventional nickel-titanium rotary instruments.

    Science.gov (United States)

    Spagnuolo, G; Ametrano, G; D'Antò, V; Rengo, C; Simeone, M; Riccitiello, F; Amato, M

    2012-12-01

    To evaluate the effects of repeated autoclave sterilization cycles on surface topography of conventional nickel-titanium ( NiTi ) and titanium nitride ( TiN )-coated rotary instruments. A total of 60 NiTi rotary instruments, 30 ProTaper (Dentsply Maillefer) and 30 TiN -coated AlphaKite (Komet/Gebr. Brasseler), were analysed. Instruments were evaluated in the as-received condition and after 1, 5 and 10 sterilization cycles. After sterilization, the samples were observed using scanning electron microscope (SEM), and surface chemical analysis was performed on each instrument with energy dispersive X-ray spectroscopy (EDS). Moreover, the samples were analysed by atomic force microscopy (AFM), and roughness average (Ra) and the root mean square value (RMS) of the scanned surface profiles were recorded. Data were analysed by means of anova followed by Tukey's test. Scanning electron microscope observations revealed the presence of pitting and deep milling marks in all instruments. EDS analysis confirmed that both types of instruments were composed mainly of nickel and titanium, whilst AlphaKite had additional nitride. After multiple autoclave sterilization cycles, SEM examinations revealed an increase in surface alterations, and EDS values indicated changes in chemical surface composition in all instruments. Ra and RMS values of ProTaper significantly increased after 5 (P = 0.006) and 10 cycles (P = 0.002) with respect to the as-received instruments, whilst AlphaKite showed significant differences compared with the controls after 10 cycles (P = 0.03). Multiple autoclave sterilization cycles modified the surface topography and chemical composition of conventional and TiN -coated NiTi rotary instruments. © 2012 International Endodontic Journal.

  1. Temperatures of exploding nuclei

    Energy Technology Data Exchange (ETDEWEB)

    Serfling, V.; Schwarz, C.; Begemann-Blaich, M.; Fritz, S.; Gross, C.; Kleinevoss, U.; Kunze, W.D; Lynen, U.; Mahi, M.; Mueller, W.F.J.; Odeh, T.; Schnittker, M.; Trautmann, W.; Woerner, A.; Xi, H. [Gesellschaft fuer Schwerionenforschung mbH, Darmstadt (Germany); Bassini, R.; Iori, I.; Moroni, A.; Petruzzelli, F. [Milan Univ. (Italy). Ist. di Scienze Fisiche]|[Istituto Nazionale di Fisica Nucleare, Milan (Italy); Gaff, S.J.; Kunde, G.J. [Michigan State Univ., East Lansing, MI (United States). Dept. of Physics and Astronomy]|[Michigan State Univ., East Lansing, MI (United States). National Superconducting Cyclotron Lab.; Imme, G.; Maddalena, V.; Nociforo, C.; Raciti, G.; Riccobene, G.; Romano, F.P.; Saija, A.; Sfienti, C.; Verde, G. [Catania Univ. (Italy). Dipt. di Fisica]|[Istituto Nazionale di Fisica Nucleare, Catania (Italy); Moehlenkamp, T.; Seidel, W. [Forschungszentrum Rossendorf e.V. (FZR), Dresden (Germany); Ocker, B.; Schuettauf, A. [Frankfurt Univ. (Germany). Inst. fuer Kernphysik; Pochodzalla, J. [Max-Planck-Institut fuer Kernphysik, Heidelberg (Germany); Trzcinski, A.; Zwieglinski, B. [Soltan Inst. for Nuclear Studies, Warsaw (Poland)

    1998-01-01

    Breakup temperatures in central collisions of {sup 197}Au+{sup 197}Au at bombarding energies E/A=50 to 200 MeV were determined with two methods. Isotope temperatures, deduced from double ratios of hydrogen, helium, and lithium isotopic yields, increase monotonically with bombarding energy from 5 MeV to 12 MeV, in qualitative agreement with a scenario of chemical freeze-out after adiabatic expansion. Excited-state temperatures, derived from yield ratios of states in {sup 4}He, {sup 5,6}Li, and {sup 8}Be, are about 5 MeV, independent of the projectile energy, and seem to reflect the internal temperature of fragments at their final separation from the system. (orig.)

  2. Comparative study and histomorphometric analysis of bone allografts lyophilized and sterilized by autoclaving, gamma irradiation and ethylene oxide in rats

    Directory of Open Access Journals (Sweden)

    Otavio Machado de Almeida

    2013-01-01

    Full Text Available PURPOSE: To compare three sterilization methods (autoclave, gamma irradiation and ethylene oxide over non demineralized lyophilized bone allografts. METHODS: Bone allografts were implanted on paravertebral muscles of 21 rats. After 30 days animals were sacrificed and grafts underwent comparative analysis regarding histomorphometric and macroscopic parameters. RESULTS: Allografts that underwent the three sterilization methods presents similar weight gain, cortical thickness similar to control group, and less fibrosis than the control group. Grafts that underwent sterilization in autoclave presented less presence of multinucleated giant cells, although not statistically significant. There was also no statistically significant difference regarding mineralization on the three groups. CONCLUSION: The three sterilization methods cause similar effects on bone allografts regarding macroscopic and histomorphometric parameters.

  3. Utilization of potatoes for life support systems. II - The effects of temperature under 24-h and 12-h photoperiods

    Science.gov (United States)

    Wheeler, Raymond M.; Steffen, Kenneth L.; Tibbitts, Theodore W.; Palta, Jiwan P.

    1986-01-01

    The effects of temperature and the photoperiod length on the growth and tuberization of Norland potatoes were investigated for two photoperiods, 12-h and 24-hr at 400 micromol/sq m per sec PPF, and at temperatures of 12, 16, 20, 24, and 28 C. It was found that stem length increased with increasing temperature under both photoperiods. The highest tuber yield was obtained at 16 C under the 24-hr photoperiod and at 20 C under the 12-hr photoperiod (i.e., increasing the photoperiod from 12 to 24 hrs effectively decreases the optimal temperature for tuber formation). Little or no tuber formation occurred at 28 C under either photoperiod.

  4. Two related lithium calixarene complexes, [p-tert-butylcalix[4]arene(OMe)(OH)2(OLi)](2).4MeCN and {p-tert-butylcalix[4]arene(OH)2(OLi)[OLi(NCMe)2]}(2).8MeCN, determined using synchrotron radiation.

    Science.gov (United States)

    Lee, Darren S; Elsegood, Mark R J; Redshaw, Carl; Zhan, Shuzhong

    2009-08-01

    The crystal structures of acetonitrile solvates of two related lithium calixarene complexes have been determined by low-temperature single-crystal X-ray diffraction using synchrotron radiation. Bis(mu-5,11,17,23-tetra-tert-butyl-26,28-dihydroxy-25-methoxy-27-oxidocalix[4]arene)dilithium(I) acetonitrile tetrasolvate, [Li2(C45H57O4)2].4C2H3N or [p-tert-butylcalix[4]arene(OMe)(OH)2(OLi)](2).4MeCN, (I), crystallizes with the complex across a centre of symmetry and with four molecules of unbound acetonitrile of crystallization per complex. Tetraacetonitrilebis(mu-5,11,17,23-tetra-tert-butyl-26,28-dihydroxy-25,27-dioxidocalix[4]arene)tetralithium(I) acetonitrile octasolvate, [Li4(C44H54O4)2(C2H3N)4].8C2H3N or {p-tert-butylcalix[4]arene(OH)2(OLi)[OLi(NCMe)2]}(2).8MeCN, (II), also crystallizes with the complex lying across a centre of symmetry and contains eight molecules of unbound acetonitrile per complex plus four more directly bound to two of the lithium ions, two on each ion. The cores of both complexes are partially supported by O-H...O hydrogen bonds. The methoxy methyl groups in (I) prevent the binding of any more than two Li+ ions, while the corresponding two O-atom sites in (II) bind an extra Li(+) ion each, making four in total. The calixarene cone adopts an undistorted cone conformation in (I), but an elliptical one in (II).

  5. Temperature distribution of thick thermoset composites

    Science.gov (United States)

    Guo, Zhan-Sheng; Du, Shanyi; Zhang, Boming

    2004-05-01

    The development of temperature distribution of thick polymeric matrix laminates during an autoclave vacuum bag process was measured and compared with numerically calculated results. The finite element formulation of the transient heat transfer problem was carried out for polymeric matrix composite materials from the heat transfer differential equations including internal heat generation produced by exothermic chemical reactions. Software based on the general finite element software package was developed for numerical simulation of the entire composite process. From the experimental and numerical results, it was found that the measured temperature profiles were in good agreement with the numerical ones, and conventional cure cycles recommended by prepreg manufacturers for thin laminates should be modified to prevent temperature overshoot.

  6. Cellular Composites with Ambient and Autoclaved Type of Hardening with Application of Nanostructured Binder

    International Nuclear Information System (INIS)

    Nelyubova, V; Pavlenko, N; Netsvet, D

    2015-01-01

    The research presents the dimensional and structural characteristics of nonhydrational hardening binders - nanostructured binders. Rational areas of their use in composites for construction purposes are given. The paper presents the results of the development of natural hardening foam concrete and aerated autoclaved concrete for thermal insulating and construction and thermal insulating purposes. Thus nanostructured binder (NB) in the composites was used as a primary binder and a high reactive modifier. (paper)

  7. Embedding of MEMS pressure and temperature sensors in carbon fiber composites: a manufacturing approach

    Science.gov (United States)

    Javidinejad, Amir; Joshi, Shiv P.

    2000-06-01

    In this paper embedding of surface mount pressure and temperature sensors in the Carbon fiber composites are described. A commercially available surface mount pressure and temperature sensor are used for embedding in a composite lay- up of IM6/HST-7, IM6/3501 and AS4/E7T1-2 prepregs. The fabrication techniques developed here are the focus of this paper and provide for a successful embedding procedure of pressure sensors in fibrous composites. The techniques for positioning and insulating, the sensor and the lead wires, from the conductive carbon prepregs are described and illustrated. Procedural techniques are developed and discussed for isolating the sensor's flow-opening, from the exposure to the prepreg epoxy flow and exposure to the fibrous particles, during the autoclave curing of the composite laminate. The effects of the autoclave cycle (if any) on the operation of the embedded pressure sensor are discussed.

  8. Effect of pullulanase debranching and storage temperatures on structural characteristics and digestibility of sweet potato starch

    Directory of Open Access Journals (Sweden)

    Ayenampudi Surendra Babu

    2018-04-01

    Full Text Available The effect of autoclaving (120 °C/30 min, debranching (2% pullulanase/1 h and storage at 4 °C (DS4 or 32 °C (DS32 or 60 °C (DS60 for 24 h on starch fractions, functional, pasting, thermal and structural properties of sweet potato starch was investigated. Results showed that DS4 sample displayed the lower functional properties than other modified starches. Debranching showed a significant increase in the apparent amylose content of native starch from 18.56% to 25%. A higher yield of RS (28.76% was observed in debranched starch stored at 4 °C (DS4 due to the higher degree of retrogradation. All debranched starches showed a substantial decrease in pasting profile and higher gelatinization temperatures than in native starch. B + V X-ray diffraction pattern was observed in debranched starches with increased crystallinity value. The scanning electron micrographs of debranched starches showed rough plate-like surfaces with irregularly shaped structures were observed due to debranching and retrogradation during storage. The study concludes that a combination of autoclaving, debranching and subsequent storage at 4 °C is best technique to produce a higher amount of resistant starch in the sweet potato starch. Keywords: Pullulanase, Functional properties, Resistant starch, RVA, XRD, SEM

  9. The Effect of Autoclaving on Torsional Moment of Two Nickel-Titanium Endodontic Files

    Science.gov (United States)

    2012-01-01

    titanium endodontic files 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) J. B. King, H. W. Roberts, B. E... Endodontic Journal, doi:10.1111/j.1365- 2591.2011.01958.x 45, 156–161, 2012 doi:10.1111/j.1365-2591.2011.01958.x Wiley Blackwell Publishing, 111 River...autoclaving on torsional strength of two nickel–titanium (NiTi) rotary endodontic files: Twisted Files (SybronEndo, Orange, CA, USA) and GT Series X

  10. Determination of metal concentrations in certified plastic reference materials after small-size autoclave and microwave-assisted digestion followed with inductively coupled plasma optical emission spectrometry

    Science.gov (United States)

    Lehtimäki, Esa; Väisänen, Ari

    2017-01-01

    The digestion methods for the determination of As, Cd, Cr, Pb, Sb, Sn and Zn concentrations in plastic samples using microwave-assisted digestion (MW-AD) and small-size autoclave digestion was developed. The certified polyethylene, polypropylene, polyvinyl chloride and acrylonitrile butadiene styrene certified reference materials were used in order to find digestion method working properly for several sample matrices. Efficiency of the digestion methods was evaluated by analyzing the residual carbon in digests by TOC analyzer. MW-AD using a mixture of 7 mL of HNO3 and 3 mL of H2O2 as a digestion solution resulted in excellent recoveries for As, Cd, Pb, Sb and Zn, and were in the range of 92-107% for all the analytes except Pb in polyethylene material. Autoclave digestion using 5 mL of concentrated HNO3 as a digestion solution resulted in similar recoveries with the exception of a higher As recovery (98%). Tin recovery resulted in low level after both MW-AD and autoclave digestion. Autoclave digestion was further developed resulting in a partially open two-step digestion process especially for the determination of Sn and Cr. The method resulted in higher recoveries of Sn and Cr (87 and 76%) but with the lower concentration of easily volatile As, Cd and Sb.

  11. The relative safety of gamma-ray, autoclave, and ethylene oxide gas sterilization of thermosetting polyurethane.

    Science.gov (United States)

    Shintani, H

    1995-01-01

    Sterilization of polyurethane (PU) produces 4,4'-methylenedianiline (MDA), a known carcinogen, and various other compounds. The relationships of the components of PU to the formation of these compounds by sterilization were studied. Specimens of PU fabricated from different combinations of isocyanates and polyols were obtained from dialyzers. The molecular weight of the particular polyol was found to influence the production of MDA by sterilization. Sterilization also produced many unidentified compounds. MDA production was not always associated with the production of the other compounds. Compared with gamma-ray irradiation and ethylene oxide gas (EOG) sterilization, autoclave sterilization eluted more hydrophilic compounds. This phenomenon was significant for PUs produced from smaller-molecular-weight polyols. The combination of autoclave sterilization and a PU produced from a larger-molecular-weight polyol is recommended to minimize the production of potentially toxic compounds. Of the techniques studied, EOG sterilization produced the least amounts of MDA and the other compounds, but the residue of EOG is itself problematic. The risk posed by the amounts of MDA extracted was not significant, but the biological safety of the other compounds remains to be determined.

  12. NON-AUTOCLAVE SILICATE BRICK

    Directory of Open Access Journals (Sweden)

    V. N. Yaglov

    2015-01-01

    Full Text Available The paper proposes a technology for obtaining bricks on the basis of lime-silica mixtures where chemical interactions are practically completely realized in dispersive state at the stage of preparation of binding contact maturing and raw mixture as a whole. The role of forming operation (moulding is changed in principle because in this case conversion of dispersive system into a rock-like solid occurs and due to this the solid obtains complete water-resistance in contact with water immediately after forming operation. Theoretical basis for the developed technology is capability of silicate dispersive substances (hydrated calcium silicate to transit in non-stable state, to form a rock-like water-resistant solid in the moment of mechanical load application during forming process. Specific feature of the proposed method is an exclusion of additional operations for autoclaving of products from the process of obtaining a silicate brick.Synthetic hydrated calcium silicate in contrast to natural ones are more uniform in composition and structure, they contain less impurities and they are characterized by dispersive composition and due to the mentioned advantages they find wider practical application. Contact-condensation binders permit to manipulate product properties on their basis and ensure maximum correspondence to the requirements of the concrete application. Raw material sources for obtaining synthetic hydrated calcium silicates are practically un-limited because calcium-silicon containing substances are found as in various technogenic wastes so in natural compounds as well. So the problem for obtaining hydrated calcium silicates having contact-condensation ability for structure formation becomes more and more actual one. This transition is considered as dependent principally on arrangement rate of substance particles which determined the level of its instability.

  13. Out-of-Plane Bending Properties of Out-of-Autoclave Thermosetting Prepregs during Forming Processes

    OpenAIRE

    Hassan A. Alshahrani; Mehdi H. Hojjati

    2016-01-01

    In order to predict and model wrinkling which is caused by out of plane deformation due to compressive loading in the plane of the material during composite prepregs forming, it is necessary to quantitatively understand the relative magnitude of the bending stiffness. This study aims to examine the bending properties of out-of-autoclave (OOA) thermosetting prepreg under vertical cantilever test condition. A direct method for characterizing the bending behavior of composite prepregs was develo...

  14. Cracking in autoclaved aerated concrete: Experimental investigation and XFEM modeling

    International Nuclear Information System (INIS)

    Ferretti, D.; Michelini, E.; Rosati, G.

    2015-01-01

    The paper aims to investigate and model cracking development in beams and deep-beams made of autoclaved aerated concrete (AAC). Fracture mechanics of AAC has been first studied by performing three-point bending tests on beams, similar to those commonly used for ordinary concrete elements. In some of these tests, crack growth has been also monitored by using ESPI laser technique. In this way, it has been possible to calibrate the main parameters of a proper cohesive law by means of extended finite element inverse analysis. Subsequently, cracking tests have been also performed on deep-beams, whose behavior is more representative of full scale walls. To validate the proposed cohesive law, deep-beam experimental behavior has been finally simulated through XFEM

  15. Cracking in autoclaved aerated concrete: Experimental investigation and XFEM modeling

    Energy Technology Data Exchange (ETDEWEB)

    Ferretti, D., E-mail: daniele.ferretti@unipr.it [Department of Civil, Environmental, Land Management Engineering and Architecture, University of Parma, P.co Area delle Scienze 181/A, 43124 Parma (Italy); Michelini, E. [Department of Civil, Environmental, Land Management Engineering and Architecture, University of Parma, P.co Area delle Scienze 181/A, 43124 Parma (Italy); Rosati, G. [Department of Civil and Environmental Engineering, Politecnico di Milano, Piazza L. Da Vinci 32, 20133 Milano (Italy)

    2015-01-15

    The paper aims to investigate and model cracking development in beams and deep-beams made of autoclaved aerated concrete (AAC). Fracture mechanics of AAC has been first studied by performing three-point bending tests on beams, similar to those commonly used for ordinary concrete elements. In some of these tests, crack growth has been also monitored by using ESPI laser technique. In this way, it has been possible to calibrate the main parameters of a proper cohesive law by means of extended finite element inverse analysis. Subsequently, cracking tests have been also performed on deep-beams, whose behavior is more representative of full scale walls. To validate the proposed cohesive law, deep-beam experimental behavior has been finally simulated through XFEM.

  16. Confirming Sterility of an Autoclaved Infected Femoral Component for Use in an Articulated Antibiotic Knee Spacer: A Pilot Study.

    Science.gov (United States)

    Lyons, Steven T; Wright, Coy A; Krute, Christina N; Rivera, Frances E; Carroll, Ronan K; Shaw, Lindsey N

    2016-01-01

    Antibiotic spacer designs have proven effective at eradicating infection during a two-stage revision arthroplasty. Temporary reuse of the steam-sterilized femoral component and a new all poly tibia component has been described as an effective articulating antibiotic spacer, but sterility concerns persist. Six explanted cobalt chrome femurs from patients with grossly infected TKA's and six stock femurs inoculated with different bacterial species were confirmed to be bacteria-free after autoclaving under a standard gravity-displacement cycle. The effect of steam sterilization on cobalt chrome fragments contaminated with MRSA biofilm was analyzed microscopically to quantify remaining biofilm. The autoclave significantly reduced the biofilm burden on the cobalt chrome fragments. This study confirmed sterility of the femur after a standard gravity-displacement cycle (132°C, 27 PSIG, 10 minutes). Copyright © 2016 Elsevier Inc. All rights reserved.

  17. Magnetoelectric(ME) Composites and Functional Devices Based on ME Effect

    Science.gov (United States)

    Gao, Junqi

    Magnetoelectric (ME) effect, a cross-coupling effect between magnetic and electric orders, has stimulated lots of investigations due to the potential for applications as multifunctional devices. In this thesis, I have investigated and optimized the ME effect in Metglas/piezo-fibers ME composites with a multi-push pull configuration. Moreover, I have also proposed several devices based on such composites. In this thesis, several methods for ME composites optimization have been investigated. (i) the ME coefficients can be enhanced greatly by using single crystal fibers with high piezoelectric properties; (ii) the influence of volume ratio between Metglas and piezo-fibers on ME coefficients has been studied both experimentally and theoretically. Modulating the volume ratio can increase the ME coefficient greatly; and (iii) the annealing process can change the properties of Metglas, which can enhance the ME response as well. Moreover, one differential structure for ME composites has been proposed, which can reject the external vibration noise by a factor of 10 to 20 dB. This differential structure may allow for practical applications of such sensors in real-world environments. Based on optimized ME composites, two types of AC magnetic sensor have been developed. The objective is to develop one alternative type of magnetic sensor with low noise, low cost and room-temperature operation; that makes the sensor competitive with the commercially available magnetic sensor, such as Fluxgate, GMR, SQUID, etc. Conventional passive sensors have been fully investigated, including the design of sensor working at specific frequency range, sensitivity, noise density characterization, etc. Furthermore, the extremely low frequency (man-portable multi-axial geomagnetic sensor has been developed which has the highest resolution of 10 nT for DC magnetic field. Based on the geomagnetic sensor, some demonstrations have been finished, such as orientation monitor, magnetic field mapping, and

  18. The effects of autoclave sterilization on the cyclic fatigue resistance of ProTaper Universal, ProTaper Next, and ProTaper Gold nickel-titanium instruments.

    Science.gov (United States)

    Özyürek, Taha; Yılmaz, Koray; Uslu, Gülşah

    2017-11-01

    It was aimed to compare the cyclic fatigue resistances of ProTaper Universal (PTU), ProTaper Next (PTN), and ProTaper Gold (PTG) and the effects of sterilization by autoclave on the cyclic fatigue life of nickel-titanium (NiTi) instruments. Eighty PTU, 80 PTN, and 80 PTG were included to the present study. Files were tested in a simulated canal. Each brand of the NiTi files were divided into 4 subgroups: group 1, as received condition; group 2, pre-sterilized instruments exposed to 10 times sterilization by autoclave; group 3, instruments tested were sterilized after being exposed to 25%, 50%, and 75% of the mean cycles to failure, then cycled fatigue test was performed; group 4, instruments exposed to the same experiment with group 3 without sterilization. The number of cycles to failure (NCF) was calculated. The data was statistically analyzed by using one-way analysis of variance and post hoc Tukey tests. PTG showed significantly higher NCF than PTU and PTN in group 1 ( p Autoclaving increased the cyclic fatigue resistances of PTN and PTG.

  19. Light particle probes of expansion and temperature evolution: Coalescence model analyses of heavy ion collisions at 47A MeV

    International Nuclear Information System (INIS)

    Hagel, K.; Wada, R.; Cibor, J.; Lunardon, M.; Marie, N.; Alfaro, R.; Shen, W.; Xiao, B.; Zhao, Y.; Majka, Z.

    2000-01-01

    The reactions 12 C+ 116 Sn, 22 Ne+Ag, 40 Ar+ 100 Mo, and 64 Zn+ 89 Y have been studied at 47A MeV projectile energy. For these reactions the most violent collisions lead to increasing amounts of fragment and light particle emission as the projectile mass increases. This is consistent with quantum molecular dynamics (QMD) model simulations of the collisions. Moving source fits to the light charged particle data have been used to gain a global view of the evolution of the particle emission. Comparisons of the multiplicities and spectra of light charged particles emitted in the reactions with the four different projectiles indicate a common emission mechanism for early emitted ejectiles even though the deposited excitation energies differ greatly. The spectra for such ejectiles can be characterized as emission in the nucleon-nucleon frame. Evidence that the 3 He yield is dominated by this type of emission and the role of the collision dynamics in determining the 3 H/ 3 He yield ratio are discussed. Self-consistent coalescence model analyses are applied to the light cluster yields, in an attempt to probe emitter source sizes and to follow the evolution of the temperatures and densities from the time of first particle emission to equilibration. These analyses exploit correlations between ejectile energy and emission time, suggested by the QMD calculations. In this analysis the degree of expansion of the emitting system is found to increase with increasing projectile mass. The double isotope yield ratio temperature drops as the system expands. Average densities as low as 0.36ρ 0 are reached at a time near 100 fm/c after contact. Calorimetric methods were used to derive the mass and excitation energy of the excited nuclei which are present after preequilibrium emission. The derived masses range from 102 to 116 u and the derived excitation energies increase from 2.6 to 6.9 MeV/nucleon with increasing projectile mass. A caloric curve is derived for these expanded A∼110

  20. School Me, School Me Not, Street Me, Street Me Not…

    DEFF Research Database (Denmark)

    Gravesen, David Thore; Frostholm, Peter Hornbæk

    School Me, School Me Not, Street Me, Street Me Not… (1099) David Thore Gravesen, Peter Hornbæk Frostholm ECER 2016, 14. Communities, Families and Schooling in Educational Research, Session: 14 SES 10 A When picking leaves of a marguerite, whilst doing the “she loves me, she loves me not” game, you....... Obviously, the skaters attend the site to skate. But also other, more vulnerable groupings, use the site to socialize, meet peers and perhaps escape an unreliable and risky family arena. One particular group, the self-named Thugz, primarily formed around a number of young boys with non-Danish ethnic...... milieu. With a criminal gang-like behavior (Hoeben & Weerman 2013; Hviid 2007; Rasmussen 2012) involving petty crime and violence, one would think the group members would be indifferent towards their schooling and future careers. This was not the case. The informants proved to be very aware...

  1. Uranium recovery by leaching with sodium carbonate at high temperature and pressure

    International Nuclear Information System (INIS)

    Soerensen, E.; Koefoed, S.; Lundgaard, T.

    1983-11-01

    The principal uranium bearing mineral in Greenland steenstrupine is a complex sodium REE phosphosilicate in which Fe, Mn, Th, U are minor constituents. The Na 2 CO 3 extractant is used for specially acidconsuming ores. However, steenstrupine is decomposed by Na 2 CO 3 only at temperatures above 220degC, so the leaching must be carried out under pressure. Laboratory tests have shown the optimal temperature to be 260degC and the leach liquor composition120 g/l of NaHCO 3 and 20 g/l of Na 2 CO 3 . Addition of oxygen is necessary as uranium will not dissolve in carbonate unless it is brought in its highest state of oxidation. According to the laboratory tests it may be estimated that 1 kg of ore suspended in 1 l of leach liquor and ground to 80% minus 200 mesh can be extracted in 20-40 minutes. On the basis of data obtained a process was suggested in which the ore is ground with carbonate leach liquor to a suitable suspension which is fed to an autoclave with a retentiontime of 20 minutes at 260degC. The residue is filtered off and the liquor reused for grinding and ex- traction. The demand for a reaction temperature near 300degC, a pressure up to 120 atm. and a continuos operation favours a tubular flow autoclave with so narrow a bore that the turbulence provides the mechanical agitation of the suspension. From the mined material it appears that more than 80% of the uranium can be extracted in the pipe autoclave. Some samples give off the obtainable uranium in 20 minutes. The precipitated yellow cake is contaminated with more Na and Si than admitted by international standards. (EG)

  2. Relation between Portland cement carbonation, range of clinker burning and some expansive phenomena in the autoclave test

    Directory of Open Access Journals (Sweden)

    Ruiz de Cauna, A.

    1975-12-01

    Full Text Available Not availableEn este trabajo se estudia el doble pico que aparece en la región de altas temperaturas de las curvas derivatométricas, realizadas en atmósfera de vapor de agua, de los cementos portland anhidros e hidratados y en general el efecto de la carbonatación sobre los silicatos y aluminatos presentes en los cementos portland, especialmente sobre el perfil de las curvas derivatométricas de los cementos portland anhidros e hidratados. Se recogen y examinan los cambios experimentados en el doble pico al someter los cementos a la acción de diversos tratamientos y de agentes modificantes, tales como el tiempo, el CO2, la hidratación normal, las hidrataciones bajo agua a ebullición, en autoclave y en suspensión acuosa con agitación, la adición de puzolana y de fuertes proporciones de S04Ca. Se estudia y compara, asimismo, el comportamiento al análisis térmico bajo vapor de agua y al ensayo de autoclave de algunos clínkeres y cementos que presentan el doble pico en forma acusada y poco apreciable, respectivamente. De los resultados obtenidos se deducen conclusiones que explican los comportamientos experimentales observados. Las principales conclusiones se refieren a la interpretación de los picos que aparecen en las curvas derivatométricas o de velocidad de pérdida de peso de los cementos portland anhidros e hidratados, y a algunos aspectos de su carbonatación, a la probable existencia de un compuesto intermedio, consecuencia de la incompleta formación del silicato tricálcico y a la explicación de determinadas grandes expansiones producidas en el ensayo de autoclave.

  3. Comparative Evaluation of Dimensional Accuracy of Elastomeric Impression Materials when Treated with Autoclave, Microwave, and Chemical Disinfection.

    Science.gov (United States)

    Kamble, Suresh S; Khandeparker, Rakshit Vijay; Somasundaram, P; Raghav, Shweta; Babaji, Rashmi P; Varghese, T Joju

    2015-09-01

    Impression materials during impression procedure often get infected with various infectious diseases. Hence, disinfection of impression materials with various disinfectants is advised to protect the dental team. Disinfection can alter the dimensional accuracy of impression materials. The present study was aimed to evaluate the dimensional accuracy of elastomeric impression materials when treated with different disinfectants; autoclave, chemical, and microwave method. The impression materials used for the study were, dentsply aquasil (addition silicone polyvinylsiloxane syringe and putty), zetaplus (condensation silicone putty and light body), and impregum penta soft (polyether). All impressions were made according to manufacturer's instructions. Dimensional changes were measured before and after different disinfection procedures. Dentsply aquasil showed smallest dimensional change (-0.0046%) and impregum penta soft highest linear dimensional changes (-0.026%). All the tested elastomeric impression materials showed some degree of dimensional changes. The present study showed that all the disinfection procedures produce minor dimensional changes of impression material. However, it was within American Dental Association specification. Hence, steam autoclaving and microwave method can be used as an alternative method to chemical sterilization as an effective method.

  4. Synthesis of (E-2,4-Dinitro-N-((2E,4E-4-phenyl-5-(pyrrolidin-1-ylpenta-2,4-dienylideneaniline

    Directory of Open Access Journals (Sweden)

    Mostafa Fesanghari

    2009-07-01

    Full Text Available (E-2,4-Dinitro-N-((2E,4E-4-phenyl-5-(pyrrolidin-1-ylpenta-2,4-dienylidene aniline dye was prepared in one pot by reaction of premade N-2,4-dinitrophenyl-3-phenylpyridinium chloride (DNPPC and pyrrolidine in absolute MeOH.

  5. Epigenetic Regulation of Vitamin D 24-Hydroxylase/CYP24A1 in Human Prostate Cancer

    Science.gov (United States)

    Luo, Wei; Karpf, Adam R.; Deeb, Kristin K.; Muindi, Josephia R.; Morrison, Carl D.; Johnson, Candace S.; Trump, Donald L.

    2010-01-01

    Calcitriol, a regulator of calcium homeostasis with antitumor properties, is degraded by the product of the CYP24A1 gene which is downregulated in human prostate cancer by unknown mechanisms. We found that CYP24A1 expression is inversely correlated with promoter DNA methylation in prostate cancer cell lines. Treatment with the DNA methyltransferase inhibitor 5-aza-2′-deoxycytidine (DAC) activates CYP24A1 expression in prostate cancer cells. In vitro methylation of the CYP24A1 promoter represses its promoter activity. Furthermore, inhibition of histone deacetylases by trichostatin A (TSA) enhances the expression of CYP24A1 in prostate cancer cells. ChIP-qPCR reveals that specific histone modifications are associated with the CYP24A1 promoter region. Treatment with TSA increases H3K9ac and H3K4me2 and simultaneously decreases H3K9me2 at the CYP24A1 promoter. ChIP-qPCR assay reveals that treatment with DAC and TSA increases the recruitment of VDR to the CYP24A1 promoter. RT-PCR analysis of paired human prostate samples reveals that CYP24A1 expression is down-regulated in prostate malignant lesions compared to adjacent histologically benign lesions. Bisulfite pyrosequencing shows that CYP24A1 gene is hypermethylated in malignant lesions compared to matched benign lesions. Our findings indicate that repression of CYP24A1 gene expression in human prostate cancer cells is mediated in part by promoter DNA methylation and repressive histone modifications. PMID:20587525

  6. Effect of Autoclave Cycles on Surface Characteristics of S-File Evaluated by Scanning Electron Microscopy

    OpenAIRE

    Razavian, Hamid; Iranmanesh, Pedram; Mojtahedi, Hamid; Nazeri, Rahman

    2015-01-01

    Introduction: Presence of surface defects in endodontic instruments can lead to unwanted complications such as instrument fracture and incomplete preparation of the canal. The current study was conducted to evaluate the effect of autoclave cycles on surface characteristics of S-File by scanning electron microscopy (SEM). Methods and Materials: In this experimental study, 17 brand new S-Files (#30) were used. The surface characteristics of the files were examined in four steps (without autocla...

  7. Solvation of UCl{sub 6}{sup 2-} anionic complex by MeBu{sub 3}N{sup +}, BuMe{sub 2}Im{sup +} and BuMeIm{sup +} cations

    Energy Technology Data Exchange (ETDEWEB)

    Bosse, Emilie; Den Auwer, Christophe; Berthon, Claude; Guilbaud, Philippe; Moisy, Philippe [CEA Marcoule, DRCP/SCPS, BP 17171, 30207 Bagnols sur Ceze Cedex (France); Grigoriev, Mikhail S. [A.N. Frumkin Institute of Physical Chemistry and Electrochemistry, RAS, Leninskii Prosp. 31, 119991 Moscow (Russian Federation); Nikitenko, Serguei [CNAB, UMR 5084, CNRS - Universite de Bordeaux 1, BP 120 Le Haut Vigneau, 33175 Gradignan Cedex (France); Le Naour, Claire; Cannes, Celine [IPN, UMR 8608, CNRS, Universite Paris-Sud, 91406 Orsay (France)

    2008-07-01

    The complexes [MeBu{sub 3}N]{sub 2}[UCl{sub 6}] and [BuMe{sub 2}Im]{sub 2}[UCl{sub 6}] were characterized in the solid state and in solution of [MeBu{sub 3}N][Tf{sub 2}N], [BuMe{sub 2}Im][Tf{sub 2}N] and [BuMeIm][Tf{sub 2}N] room temperature ionic liquids using single-crystal XRD, EXAFS, electrochemistry, UV-visible absorption spectroscopy and NMR. In the solid and in solution, the existence of hydrogen bonding between the anionic UCl{sub 6}{sup 2-} complex and the ionic liquid cations were revealed by these techniques. The MeBu{sub 3}N{sup +} cation interacts with UCl{sub 6}{sup 2-} via the protons on the alpha carbon atoms of nitrogen. The protons of the imidazolium ring account for the interaction between the BuMe{sub 2}Im+ cation and the UCl{sub 6}{sup 2-} anion. For the BuMeIm{sup +} cation the major interaction was confirmed between the most acidic proton on C(2) and UCl{sub 6}{sup 2-}. The experimental results also show that the intensity of the interaction between the UCl{sub 6}{sup 2-} anion and the cation varies with the ionic liquid cation in the following order: MeBu{sub 3}N{sup +} {approx} BuMe{sub 2}Im{sup +} << BuMeIm{sup +}. (authors)

  8. Study of Paramagnetic Monohydrates MeSO4.1H2O (Me = Mn2+, Co2+, Fe2+, Ni2+, Cu2+

    Directory of Open Access Journals (Sweden)

    Jelšovská Kamila

    2000-09-01

    Full Text Available Nuclear magnetic resonance (NMR of protons of crystrallization water in isomorphous paramagnetic monohydrates MeSO4.1H2O with Me = Mn2+ , Co2+ , Fe2+ , Ni2+ , Cu2+ is studied in the present paper. Several physically important parameters characterizing the studied substances were derived from the NMR spectra. In this paper we analysed the dependences of the NMR second moment M2 on the magnitude of the external magnetic field induction Br and the temperature. The proton NMR spectra in paramagnetic hydrates have an asymmetric form caused by the anisotropy of the local magnetic field acting on resonating nuclei and their second moments, M2, depend linearly on the square of the external magnetic field Br. The parameters M20 (the part of the second moment M2 which corresponds to the nuclear dipole-dipole interactions and á which characterize nuclear dipole-dipole interactions of protons and paramagnetic ions, respectively, are derived from experimentally obtained dependences of M2 vs Br2. The measurements were performed at the room temperature. Calculations were realized using the approximation where two nearest neighbour ions Me2+ to each water molecule are considered. The temperature dependence of the second moment, which was realised in the temperature range 123-313 K, was more informative than the field one. Besides the individual dependences M2(T measured at fr1 and fr2 we analysed the temperature dependence of the difference ∆M2(T. Beside the second moment M20 the Curie-Weiss constant è and the magnetic moment µi of paramagnetic ions were determined from the temperature dependences. The parameters è and M20 were determined directly from the experimental data. Some knowledge on the crystalline structure for the studied substance was required for the calculation of the magnetic moment µi. By means of the classification of substances according to the Curie-Weiss parameter, the negative value of the temperature parameter è for all studied

  9. Polimerização complementar em autoclave, microondas e estufa de um compósito restaurador direto = The effect of post-cure heating in autoclave, microwave oven and conventional oven on direct composite resin

    Directory of Open Access Journals (Sweden)

    Arossi, Guilherme Anziliero

    2007-01-01

    Full Text Available Com o objetivo de tornar o processo de confecção de restaurações indiretas mais acessível, reduzindo seus custos com a resina utilizada e os métodos de polimerização complementar, este estudo testou a possibilidade de se utilizar resinas diretas com métodos de polimerização complementar alternativos. Corpos de prova foram confeccionados com a resina Charisma e fotopolimerizados por 20 segundos. Em seguida as amostras foram submetidas à polimerização complementar em autoclave, microondas e estufa. Foram estabelecidos dois grupos controles: um controle negativo, que consistiu na utilização da resina Charisma fotopolimerizada convencionalmente (20s; e um grupo controle positivo, formado por amostras do compósito restaurador indireto Targis. O ensaio de microdureza Knoop foi realizado após uma semana de armazenagem e os resultados submetidos à análise estatística. Os três métodos de polimerização complementar propostos determinaram um aumento na microdureza do compósito restaurador direto quando comparado ao controle negativo (p 0,05. Conclui-se que, considerando o desenho experimental deste estudo, a polimerização complementar em autoclave, microondas ou estufa aumenta a microdureza da resina Charisma previamente fotopolimerizada

  10. Evaluation of gamma irradiation and heat treatment by autoclaving in the preparation of microorganism-free carriers for biofertilizer products

    International Nuclear Information System (INIS)

    Phua Choo Kwai Hoe; Khairuddin Abdul Rahim; Ahmad Nazrul Abd Wahid

    2009-01-01

    Biofertilizer has been identified as an alternative or complementary to chemical fertilizers to increase soil fertility and crop production in sustainable farming. Biofertilizers are products containing living cells of different types of known microorganisms that may increase crop productivity through N 2 fixation, phosphate solubilization or stimulation of plant growth by synthesising phytohormones. A good biofertilizer product needs a good carrier or substrate. A good carrier should be free from microbial contamination and can optimise the growth of the biofertilizer microorganisms. Compost is commonly used as carrier or substrate for biofertilizer microorganisms. In the present study, compost produced by Nuclear Malaysia using the Natural Farming method was used as carrier for several biofertilizer products. Gamma irradiation and autoclave were used to produce sterile carrier for biofertilizer. The effectiveness for both methods was evaluated. Gamma irradiation at a dose of 50 kGy and autoclaving at 121 degree C for 60 minutes were found effective to produce sterile carriers for biofertilizer products.(Author)

  11. Alpha-gamma angular correlations in the reaction 24Mg(α, α1γ) at Esub(α) = 104 MeV

    International Nuclear Information System (INIS)

    Eyrich, W.; Hofmann, A.; Scheib, U.; Schneider, S.; Vogler, F.; Rebel, H.

    1977-05-01

    The in-plane α 1 -γ angular correlation of the reaction 24 Mg(α, α 1 γ) has been studied at a bombarding energy of 104 MeV. Double differential cross sections have been measured for 126 pairs of angles by use of a multidetector arrangement consisting of four Si(Li) particle detectors and two Ge(Li) γ-detectors. The correlation data are described very well by coupled channel calculations on the basis of a symmetric rotator model. A strong sensitivity to the sign of the quadrupole deformation has been found. This sensitivity proves to be nearly independent of the potential parameters. The main features of the observed prolate-oblate effects can be understood in the framework of a simple diffraction model. (orig.) [de

  12. Autoclaving-Derived Surface Coating with In Vitro and In Vivo Antimicrobial and Antibiofilm Efficacies.

    Science.gov (United States)

    Su, Yajuan; Zhi, Zelun; Gao, Qiang; Xie, Meihua; Yu, Meng; Lei, Bo; Li, Peng; Ma, Peter X

    2017-03-01

    Biomedical device-associated infections which engender severe threat to public health require feasible solutions. In this study, block copolymers consisting of antimicrobial, antifouling, and surface-tethering segments in one molecule are synthesized and grafted on polymeric substrates by a facile plasma/autoclave-assisted method. Hetero-bifunctional polyethylene glycol (PEG) with allyl and tosyl groups (APEG-OTs) is first prepared. PEGs with different molecular weights (1200 and 2400 Da) are employed. Polyhexamethylene guanidine (PHMG) which has excellent broad-spectrum antimicrobial activity and thermal/chemical stability, is conjugated with APEG-OTs to generate the block copolymer (APEG-PHMG). Allyl terminated PHMG (A-PHMG) without PEG segments is also synthesized by reacting PHMG with allyl glycidyl ether. The synthesized copolymers are thermal initiated by autoclaving and grafted on plasma pretreated silicone surface, forming permanently bonded bottlebrush-like coatings. Both A-PHMG and APEG 1200/2400 -PHMG coatings exhibit potent antimicrobial activity against gram-positive/negative bacteria and fungus, whereas APEG 1200/2400 -PHMG coatings show superior antifouling activity and long-term reusability to A-PHMG coating. APEG 2400 -PHMG coating demonstrates the most effective in vitro antibiofilm and protein/platelet-resistant properties, as well as excellent hemo/biocompatibility. Furthermore, APEG 2400 -PHMG greatly reduces the bacteria number with 5-log reduction in a rodent subcutaneous infection model. This rationally designed dual-functional antimicrobial and antifouling coating has great potential in combating biomedical devices/implant-associated infections. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Measurement of neutron spectra generated from bombardment of 4 to 24 MeV protons on a thick 9Be target and estimation of neutron yields

    International Nuclear Information System (INIS)

    Paul, Sabyasachi; Sahoo, G. S.; Tripathy, S. P.; Sunil, C.; Bandyopadhyay, T.; Sharma, S. C.; Ramjilal,; Ninawe, N. G.; Gupta, A. K.

    2014-01-01

    A systematic study on the measurement of neutron spectra emitted from the interaction of protons of various energies with a thick beryllium target has been carried out. The measurements were carried out in the forward direction (at 0° with respect to the direction of protons) using CR-39 detectors. The doses were estimated using the in-house image analyzing program autoTRAK-n, which works on the principle of luminosity variation in and around the track boundaries. A total of six different proton energies starting from 4 MeV to 24 MeV with an energy gap of 4 MeV were chosen for the study of the neutron yields and the estimation of doses. Nearly, 92% of the recoil tracks developed after chemical etching were circular in nature, but the size distributions of the recoil tracks were not found to be linearly dependent on the projectile energy. The neutron yield and dose values were found to be increasing linearly with increasing projectile energies. The response of CR-39 detector was also investigated at different beam currents at two different proton energies. A linear increase of neutron yield with beam current was observed

  14. Measurement of {sup 27}Al(γ,2pn){sup 24}Na Reaction Cross-sections with 55 -, 60 -, 65 - MeV Bremsstrahlung Employing MCNPX Simulation

    Energy Technology Data Exchange (ETDEWEB)

    Shin, S. G.; Kye, Y.; Cho, M. H. [POSTECH, Pohang (Korea, Republic of); Namkung, W. [Pohang Accelerator Laboratory, Pohang (Korea, Republic of); KIm, G. N.; Kim, K. [Kyungpook National Univ., Daegu (Korea, Republic of); Lee, M. W.; Kang, Y. R. [Dongnam Inst. Of Radiological and Medical Science, Busan (Korea, Republic of)

    2014-05-15

    Aluminum is used for monitoring the photon flux. The photon flux during the activation can be measured by substituting the {sup 27}Al(γ,2pn){sup 24}Na reaction cross-section induced by bremsstrahlung to reactivity equation. Therefore, if this cross-section is more accurate, gamma-ray flux can be measure more accurately. In this work, the {sup 27}Al(γ,2pn){sup 24}Na reaction cross-sections induced by 55 - 65 MeV bremsstrahlung were measured by activation technique at the Pohang Neutron Facility (PNF) which has produced the nuclear data using Time-Of-Flight method and activation technique. In order to get the photon flux, MCNPX was used. These measurement values were compared with the data of Meyer et al (1968)

  15. Compressive strength, flexural strength and thermal conductivity of autoclaved concrete block made using bottom ash as cement replacement materials

    International Nuclear Information System (INIS)

    Wongkeo, Watcharapong; Thongsanitgarn, Pailyn; Pimraksa, Kedsarin; Chaipanich, Arnon

    2012-01-01

    Highlights: ► Autoclaved aerated concrete were produced using coal bottom ash as a cement replacement material. ► Coal bottom ash was found to enhance concrete strengths. ► Thermal conductivity of concrete was not significantly affected. ► X-ray diffraction and thermal analysis show tobermorite formation. -- Abstract: The bottom ash (BA) from Mae Moh power plant, Lampang, Thailand was used as Portland cement replacement to produce lightweight concrete (LWC) by autoclave aerated concrete method. Portland cement type 1, river sand, bottom ash, aluminium powder and calcium hydroxide (Ca(OH) 2 ) were used in this study. BA was used to replace Portland cement at 0%, 10%, 20% and 30% by weight and aluminium powder was added at 0.2% by weight in order to produce the aerated concrete. Compressive strength, flexural and thermal conductivity tests were then carried out after the concrete were autoclaved for 6 h and left in air for 7 days. The results show that the compressive strength, flexural strength and thermal conductivity increased with increased BA content due to tobermorite formation. However, approximately, 20% increase in both compressive (up to 11.61 MPa) and flexural strengths (up to 3.16 MPa) was found for mixes with 30% BA content in comparison to just around 6% increase in the thermal conductivity. Thermogravimetry analysis shows C–S–H formation and X-ray diffraction confirm tobermorite formation in bottom ash lightweight concrete. The use of BA as a cement replacement, therefore, can be seen to have the benefit in enhancing strength of the aerated concrete while achieving comparatively low thermal conductivity when compared to the results of the control Portland cement concrete.

  16. Laser application in high temperature materials

    International Nuclear Information System (INIS)

    Ohse, R.W.

    1988-01-01

    The scope and priorities of laser application in materials science and technology are attracting widespread interest. After a brief discussion of the unique capabilities of laser application in the various fields of materials science, main emphasis is given on the three areas of materials processing, surface modification and alloying, and property measurements at high temperatures. In materials processing the operational regimes for surface hardening, drilling, welding and laser glazing are discussed. Surface modifications by laser melting, quenching and surface alloying, the formation of solid solutions, metastable phases and amorphous solids on the basis of rapid solidification, ion implantation and ion beam mixing are considered. The influence of solidification rates and interface velocities on the surface properties are given. The extension of property measurements up to and beyond the melting point of refractory materials into their critical region by a transient-type dynamic laser pulse heating technique is given for the three examples of vapour pressure measurement, density and heat capacity determination in the solid and liquid phases. A new approach, the laser autoclave technique, applying laser heating and x-ray shadow technique under autoclave conditions to acoustically levitated spheres will be presented. (author)

  17. Methodic aspects of autoclave tests of compact samples on cyclic crack resistance

    International Nuclear Information System (INIS)

    Pokhmurskij, V.I.; Gnyp, I.P.; Popov, A.A.; Tarasyuk, G.P.; Dutsyak, I.Z.; Timonin, V.M.

    1984-01-01

    Laboratory autoclave LAKIM-25 was created for investigation of cyclic and static crack resistance of vessel materials of power plants under the conditions close to operation ones. It enables to investigate the cyclic crack resistance of standard samples of up to 25 mm thickness in water at 623 K and 18 MPa. The friction force changes during tests from 6.1 up to 6.4 kN, therefore it is necessary to correct regularly the force of sample loading, recording the s-n diagram on a drum of UMEh-10TM plant. The periodic record of loading diagram coincides with respect to time with the necessity of controlling the change of sample pliability during crack propagation

  18. Dynamics of nucleus-nucleus collisions up to 100 MeV/u and caloric curve

    International Nuclear Information System (INIS)

    Peter, J.; Angelique, J.C.; Auger, G.

    1997-01-01

    Using the 4π multidetector array Mur + Tonneau at GANIL made it possible to determine that, at incidence energy 35-95 MeV/u, the fusion (or one main source) cross section is very small in nearly symmetrical light and medium systems. Dissipative binary collisions accompanied by mid-rapidity (participant) emission were found to dominate at all impact parameters. The excitation energy of the reconstructed quasi-projectile was obtained via calorimetry and reaches high values. Using the 4π array INDRA several new features of mid-rapidity emission were revealed: the isotopic composition, mean transverse momentum and apparent temperature do not vary with the impact parameter, whereas the number of emitted nucleons increases with decreasing impact parameter. Mid-rapidity products are more n-rich than quasi-projectile products. Hot quasi-projectiles formed in two reactions were used to study the caloric curve. The apparent temperatures were obtained from several double isotopic yield ratios and slopes of kinetic energy spectra at excitation energy per nucleon ranging up to 24 MeV. Different thermometers give different values, but all of them increase steadily with excitation energy. These data can be explained by calculations assuming a steady increase of the initial temperature with excitation energy, without a plateau which was claimed as evidence for a liquid-gas phase transition. (authors)

  19. [Zr(NEtMe)2(guan-NEtMe)2] as a novel ALD precursor: ZrO2 film growth and mechanistic studies

    NARCIS (Netherlands)

    Blanquart, T.; Niinistö, J.; Aslam, N.; Banerjee, M.; Tomczak, Y.; Gavagnin, M.; Longo, V.; Puukilainen, E.; Wanzenboeck, H.D.; Kessels, W.M.M.; Devi, A.; Hoffmann-Eifert, S.; Ritala, M.; Leskelä, M.

    2013-01-01

    [Zr(NEtMe)2(guan-NEtMe2)2], a recently developed compound, was investigated as a novel precursor for the atomic layer deposition (ALD) of ZrO2. With water as the oxygen source, the growth rate remained constant over a wide temperature range, whereas with ozone the growth rate increased steadily with

  20. 辽宁省"24节气"气温的气候特征分析%Analysis on the Climatic Characteristics of Temperature in "24 solar terms" in Liaoning Province

    Institute of Scientific and Technical Information of China (English)

    侯亚红; 路爽; 张蕊

    2011-01-01

    [目的]分析辽宁省"24节气"气温的气候特征.[方法]采用辽宁省56个测站1951~2009年的逐日气温资料,统计分析了辽宁近59年"24节气"气温的气候特征.[结果]辽宁24个节气平均气温的时间序列呈准正态分布单峰型,大暑是全年最热的节气,小暑节气次之;小寒是全年最冷的节气,大寒节气次之.辽宁24个节气中的升温幅度最大的是清明节气,气温的节气变量为4.9℃,降温幅度最大是立冬节气,气温的节气变量为- 5.1℃.与气温关系密切的小暑、大暑、小寒、大寒、处暑节气的平均气温有明显的年代际变化特征,且随着时间变化均呈先低后高的趋势.1951~1980年各节气平均气温与1981~2009年的相比,有22个节气平均气温上升,1个节气平均气温持平,仅有1个节气略有下降,节气平均气温升幅是0.66℃.[结论]该研究为气象服务提供科学依据.%[ Objective] The aim was to analyze the climatic characteristics of temperature in 24 "solar terms" in Liaoning Province. [ Method J Based on the daily temperature data from 56 stations in Iiaoning Province from 1951 to 2009, the climatic characteristics of temperature in "24 solar terms" in Liaoning Province in recent 59 years were analyzed. [ Result] The time series of average temperature in "24 solar terms" in Liaoning Province from 1951 to 2009 showed quasi normal distribution, namely single peak type, and Great Heat meant the hottest time within one year, and next came Slight Heat, while Slight Cold was the coldest time within one year, and Great Cold took the second place. A-mong 24 "solar terms" , temperature increase was most obvious on Tomb-sweeping Day, with the increase of 4.9 ℃, while temperature decreased most greatly at the Beginning of Winter, with the decrease of 5.1 ℃. There was obvious decadal variation of average temperature in Slight Heat, Great Heat, Slight Cold, Great Cold and the End of Heat which were closely related to

  1. A comparative study of 30MeV boron4+ and 60MeV oxygen8+ ion irradiated Si NPN BJTs

    International Nuclear Information System (INIS)

    Kumar, M. Vinay; Krishnaveni, S.; Yashoda, T.; Dinesh, C. M.; Krishnakumar, K. S.; Jayashree, B.; Ramani

    2015-01-01

    The impact of 30MeV boron 4+ and 60MeV oxygen 8+ ion irradiation on electrical characteristics of 2N3773 Si NPN Bipolar junction transistors (BJTs) is reported in the present study. The transistors were decapped and irradiated at room temperature. Gummel characteristics, DC current gain and Capacitance-voltage (C-V) characteristics were studied before and after irradiation at different fluences. DC current gain has decreased significantly in both boron and oxygen ion irradiation. Also the value of capacitance decreased 3-4 times with increase in fluence. Both 30MeV boron ion and 60MeV oxygen ion induced similar extent of degradation in electrical characteristics of the transistor

  2. The differences between NAD-ME and NADP-ME subtypes of C4 photosynthesis: more than decarboxylating enzymes

    Directory of Open Access Journals (Sweden)

    Xiaolan Rao

    2016-10-01

    Full Text Available As an adaptation to changing climatic conditions that caused high rates of photorespiration, C4 plants have evolved to display higher photosynthetic efficiency than C3 plants under elevated temperature, high light intensities and drought. The C4 plants independently evolved more than 60 times in 19 families of angiosperms to establish similar but not uniform C4 mechanisms to concentrate CO2 around the carboxylating enzyme Rubisco. C4 photosynthesis is divided into at least two basic biochemical subtypes based on the primary decarboxylating enzymes, NAD-dependent malic enzyme (NAD-ME and NADP-dependent malic enzyme (NADP-ME. The multiple polygenetic origins of these subtypes raise questions about the association of C4 variation between biochemical subtypes and diverse lineages. This review addresses the differences in evolutionary scenario, leaf anatomy, and especially C4 metabolic flow, C4 transporters and cell-specific function deduced from recently reported cell-specific transcriptomic, proteomic and metabolic analyses of NAD-ME and NADP-ME subtypes. Current omic analysis has revealed the extent to which component abundances differ between the two biochemical subtypes, leading to a better understanding of C4 photosynthetic mechanisms in NAD-ME and NADP-ME subtypes.

  3. Neutron Energy Spectra from Neutron Induced Fission of 235U at 0.95 MeV and of 238U at 1.35 and 2.02 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Almen, E; Holmqvist, B; Wiedling, T

    1971-09-15

    The shapes of fission neutron spectra are of interest for power reactor calculations. Recently it has been suggested that the neutron induced fission spectrum of 235U may be harder than was earlier assumed. For this reason measurements of the neutron spectra of some fissile isotopes are in progress at our laboratory. This report will present results from studies of the energy spectra of the neutrons emitted in the neutron induced fission of 235U and 238U. The measurements were performed at an incident neutron energy of 0.95 MeV for 235U and at energies of 1.35 and 2.02 MeV for 238U using time-of-flight techniques. The time-of-flight spectra were only analysed at energies higher than those of the incident neutrons and up to about 10 MeV. Corrections for neutron attenuation in the uranium samples were calculated using a Monte Carlo program. The corrected fission neutron spectra were fitted to Maxwellian temperature distributions. For 235U a temperature of 1.27 +- 0.01 MeV gives the best fit to the experimental data and for 238U the corresponding values are 1.29 +- 0.03 MeV at 1.35 MeV and 1.29 +- 0.02 MeV at 2.02 MeV

  4. Temperature measurement with neutrons

    International Nuclear Information System (INIS)

    Bizard, G.; Durand, D.; Lecolley, J.F.; Lefebvres, F.; Marques, M.; Peter, J.; Tamain, B.

    1998-01-01

    The results presented in this report were obtained from the information provided by charged products. Another alternative consists in detecting the neutrons abundantly emitted particularly by heavy nuclei. The residue channel was studied in the 40 Ar + 197 Au at 60 MeV/nucleon by means of the neutron multidetector DEMON. The evolution of the multiplicity of neutrons emitted backwards in the framework of the heavy nucleus forwardly detected as a function of the residue velocity by a silicon detector, placed at 8 degrees and at 24.5 cm from target, agrees with the expected results i.e. an increase with the residue velocity hence with the collision violence. For the same detector the first measurements show similarly a linear increase of the apparent temperature of 4.0 to around 6.5 MeV for residue velocities varying from 0.5 to 1.3 cm/ns and masses ranging from 140 to 160 uma. This first results of the analysis show therefore a good behaviour of the assembly and especially of the couple DeMoN-SyReP

  5. Building on TR-24 success. Advanced Cyclotron Systems Inc. launches a new cyclotron model

    International Nuclear Information System (INIS)

    Russell Watt; William Gyles; Alexander Zyuzin

    2015-01-01

    ACSI is designing a new 30 MeV cyclotron based on the TR-24. While minimizing changes from the proven TR-24, including maintaining the same outer dimensions, the energy of the cyclotron will be increased to 30 MeV, which will make it the most compact, non-superconducting, 30 MeV cyclotron design to date. Maximum beam current will match the TR-24 at 1 mA. With the size and footprint of a typical low energy PET cyclotron, this system will offer users a cost effective solution for a diversified facility capable of producing a wide spectrum of PET and SPECT radioisotopes for research and commercial distribution. (author)

  6. Proinsulin is stable at room temperature for 24 hours in EDTA: A clinical laboratory analysis (adAPT 3.

    Directory of Open Access Journals (Sweden)

    Jane Davidson

    Full Text Available Reference laboratories advise immediate separation and freezing of samples for the assay of proinsulin, which limit its practicability for smaller centres. Following the demonstration that insulin and C-peptide are stable in EDTA at room temperature for at least 24hours, we undertook simple stability studies to establish whether the same might apply to proinsulin.Venous blood samples were drawn from six adult women, some fasting, some not, aliquoted and assayed immediately and after storage at either 4°C or ambient temperature for periods from 2h to 24h.There was no significant variation or difference with storage time or storage condition in either individual or group analysis.Proinsulin appears to be stable at room temperature in EDTA for at least 24h. Immediate separation and storage on ice of samples for proinsulin assay is not necessary, which will simplify sample transport, particularly for multicentre trials.

  7. 加气混凝土制备工艺影响因素分析%Analysis of Influential Factors on Preparation of Autoclaved Aerated Concrete

    Institute of Scientific and Technical Information of China (English)

    罗立群; 程琪林

    2015-01-01

    Aimed at new requirements brought up by domestic building material market, autoclaved aerated concrete has been acclaimed owning to its several particular performance advantages such as lightweight, thermal insulation, acoustic insulation, anti-seismic, etc. After preparation process of auto-claved aerated concrete was briefly summarized, it focused on influence of material characteristics on the properties of the products such as siliceous material, calcareous material, vesicant, water-solid ratio and ad-ditives. Influence mechanism of curing conditions of green body, reaction process of preparation and prod-ucts microstructure on performance of autoclaved aerated concrete were introduced. Eventually, direction of development of autoclaved aerated concrete was prospected in the future.%针对建材市场节能环保产品的需求,加气混凝土制品以其独特的质轻节能、保温隔热、抗震隔音等综合性能优势而备受关注。简述了蒸压加气混凝土的制备过程,重点阐述了制备加气混凝土砌块的硅质材料、钙质材料、发气剂、水料比及添加物等物料特性对制品性能的影响,介绍了坯体养护条件、制备过程反应以及制品微观结构对加气混凝土性能的影响机理,展望了加气混凝土未来的发展方向。

  8. Hot composite systems with a > 200 and T > 6 MeV

    International Nuclear Information System (INIS)

    Crema, E.; Bresson, S.; Doubre, H.; Galin, J.; Guerreau, D.; Morjean, M.; Piasecki, E.; Pouthas, J.; Saint-Laurent, F.; Sokolov, A.; Wang, X.M.; Gatty, B.; Jacquet, D.; Piasecki, E.; Crema, E.; Wang, X.M.

    1990-01-01

    Neutron multiplicities have been measured in coincidence with the light charged particles evaporated in the backward direction for the reaction 84 Kr+ 197 Au at 32 MeV/u. A method is presented which makes possible an evaluation of the recoil velocity, excitation energy and temperature of hot and thermalized heavy composite systems formed for different impact parameters. Temperatures larger than 6 MeV are found for the most dissipative collisions

  9. Curcumin complexation with cyclodextrins by the autoclave process: Method development and characterization of complex formation.

    Science.gov (United States)

    Hagbani, Turki Al; Nazzal, Sami

    2017-03-30

    One approach to enhance curcumin (CUR) aqueous solubility is to use cyclodextrins (CDs) to form inclusion complexes where CUR is encapsulated as a guest molecule within the internal cavity of the water-soluble CD. Several methods have been reported for the complexation of CUR with CDs. Limited information, however, is available on the use of the autoclave process (AU) in complex formation. The aims of this work were therefore to (1) investigate and evaluate the AU cycle as a complex formation method to enhance CUR solubility; (2) compare the efficacy of the AU process with the freeze-drying (FD) and evaporation (EV) processes in complex formation; and (3) confirm CUR stability by characterizing CUR:CD complexes by NMR, Raman spectroscopy, DSC, and XRD. Significant differences were found in the saturation solubility of CUR from its complexes with CD when prepared by the three complexation methods. The AU yielded a complex with expected chemical and physical fingerprints for a CUR:CD inclusion complex that maintained the chemical integrity and stability of CUR and provided the highest solubility of CUR in water. Physical and chemical characterizations of the AU complexes confirmed the encapsulated of CUR inside the CD cavity and the transformation of the crystalline CUR:CD inclusion complex to an amorphous form. It was concluded that the autoclave process with its short processing time could be used as an alternate and efficient methods for drug:CD complexation. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Methane biofiltration using autoclaved aerated concrete as the carrier material.

    Science.gov (United States)

    Ganendra, Giovanni; Mercado-Garcia, Daniel; Hernandez-Sanabria, Emma; Boeckx, Pascal; Ho, Adrian; Boon, Nico

    2015-09-01

    The methane removal capacity of mixed methane-oxidizing bacteria (MOB) culture in a biofilter setup using autoclaved aerated concrete (AAC) as a highly porous carrier material was tested. Batch experiment was performed to optimize MOB immobilization on AAC specimens where optimum methane removal was obtained when calcium chloride was not added during bacterial inoculation step and 10-mm-thick AAC specimens were used. The immobilized MOB could remove methane at low concentration (~1000 ppmv) in a biofilter setup for 127 days at average removal efficiency (RE) of 28.7 %. Unlike a plug flow reactor, increasing the total volume of the filter by adding a biofilter in series did not result in higher total RE. MOB also exhibited a higher abundance at the bottom of the filter, in proximity with the methane gas inlet where a high methane concentration was found. Overall, an efficient methane biofilter performance could be obtained using AAC as the carrier material.

  11. Optical and electronic properties of sub-surface conducting layers in diamond created by MeV B-implantation at elevated temperatures

    Energy Technology Data Exchange (ETDEWEB)

    Willems van Beveren, L. H., E-mail: laurensw@unimelb.edu.au; Bowers, H.; Ganesan, K.; Johnson, B. C.; McCallum, J. C.; Prawer, S. [School of Physics, University of Melbourne, Parkville, Victoria 3010 (Australia); Liu, R. [SIMS Facility, Office of the Deputy-Vice Chancellor (Research and Development) Western Sydney University, Locked Bag 1797, Penrith, New South Wales 2751 (Australia)

    2016-06-14

    Boron implantation with in-situ dynamic annealing is used to produce highly conductive sub-surface layers in type IIa (100) diamond plates for the search of a superconducting phase transition. Here, we demonstrate that high-fluence MeV ion-implantation, at elevated temperatures avoids graphitization and can be used to achieve doping densities of 6 at. %. In order to quantify the diamond crystal damage associated with implantation Raman spectroscopy was performed, demonstrating high temperature annealing recovers the lattice. Additionally, low-temperature electronic transport measurements show evidence of charge carrier densities close to the metal-insulator-transition. After electronic characterization, secondary ion mass spectrometry was performed to map out the ion profile of the implanted plates. The analysis shows close agreement with the simulated ion-profile assuming scaling factors that take into account an average change in diamond density due to device fabrication. Finally, the data show that boron diffusion is negligible during the high temperature annealing process.

  12. Tokamak ion temperature and poloidal field diagnostics using 3 MeV protons

    International Nuclear Information System (INIS)

    Heidbrink, W.W.; Strachan, J.D.

    1984-10-01

    The 3 MeV protons created by d(d,p)t fusion reactions in a moderately sized tokamak leave the plasma on trajectories determined by the position of their birth and by the poloidal magnetic field. Pitch-angle resolution of the escaping 3 MeV protons can separately resolve the spatial distribution of the d(d,p)t fusion reactions and the poloidal field distribution inside the tokamak. These diagnostic techniques have been demonstrated on PLT with an array of collimated surface barrier detectors

  13. Low-temperature irradiation of niobium with 15-MeV neutrons

    International Nuclear Information System (INIS)

    Kerchner, H.R.; Coltman, R.R. Jr.; Klabunde, C.E.; Sekula, S.T.

    1978-01-01

    Niobium was irradiated at 4.2 K with high energy d-Be neutrons to a fluence of 3.7x10 15 n/cm 2 . The neutrons were generated at the Oak Ridge Isochronous Cyclotron by the breakup reaction of 40-MeV deuterons in a thick Be target. The resulting neutron energy spectrum was broadly peaked near 15 MeV. The 0.012-cm-diameter wire sample (RRR=200) was situated in a uniform transverse magnetic field. The critical current, flux flow resistance, and normal state resistance were measured by using a standard four-terminal technique. The critical current density and the flux flow resistivity were observed to increase with irradiation and to decrease toward the preirradiation values with subsequent isochronal annealing between 4.2 K and 360 K. Using recent theories of flux line lattice deformation, the elementary pinning force is deduced and the result is compared to theoretical calculations. (Auth.)

  14. Relation between interlaminar fracture toughness and pressure condition in autoclave molding process of GFRP composite laminates; GFRP sekisoban no autoclave seikei ni okeru atsuryoku joken to sokan hakai jinseichi tono kankei

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, J. [Osaka City University, Osaka (Japan); Motogi, S.; Fukuda, T. [Osaka City University, Osaka (Japan). Faculty of Engineering

    1998-06-15

    Relation between fracture toughness and pressure condition in autoclave molding of GF composite laminates is investigated. Glass/epoxy prepregs are molded under different curing pressures, and UD laminates of [O{sub 8}]T and [O{sub 16}]T are fabricated. The results of the double cantilever beam (DCB) test show that the curing pressure has certain influences on the interlaminar fracture toughness via the change in morphology of matrix resin and fibers between laminae, and via the change in interfacial strength of fiber and matrix. It is also found that the fiber/matrix interfacial strength increases as the curing pressure increases by SEM photographs of the fracture surface in GF UD laminates. 13 refs., 12 figs.

  15. Temperature-dependent photoluminescence analysis of 1-MeV electron irradiation-induced nonradiative recombination centers in GaAs/Ge space solar cells

    Energy Technology Data Exchange (ETDEWEB)

    Tiancheng, Yi; Pengfei, Xiao; Yong, Zheng; Juan, Tang; Rong, Wang, E-mail: wangr@bnu.edu.cn

    2016-03-01

    The effects of irradiation of 1-MeV electrons on p{sup +}–n GaAs/Ge solar cells have been investigated by temperature-dependent photoluminescence (PL) measurements in the temperature range of 10–290 K. The temperature dependence of the PL peak energy agrees well with the Varnish relation, and the thermal quenching of the total integrated PL intensity is well explained by the thermal quenching theory. Meanwhile, the thermal quenching of temperature-dependent PL confirmed that there are two nonradiative recombination centers in the solar cells, and the thermal activation energies of these centers are determined by Arrhenius plots of the total integrated PL intensity. Furthermore, the nonradiative recombination center, as a primary defect, is identified as the H3 hole trap located at E{sub v} + 0.71 eV at room temperature and the H2 hole trap located at E{sub v} + 0.41 eV in the temperature range of 100–200 K, by comparing the thermal activation and ionization energies of the defects.

  16. The Effect of Slamming Impact on Out-of-Autoclave Cured Prepregs of GFRP Composite Panels for Hulls

    OpenAIRE

    Suárez, J.C.; Townsend, P.; Sanz, E.; Ulzurrum, I. Diez de; Pinilla, P.

    2016-01-01

    This paper proposes a methodology that employs an experimental apparatus that reproduces, in pre-impregnated and cured out-of-autoclave Glass Fiber Reinforced Polymer (GFRP) panels, the phenomenon of slamming or impact on the bottom of a high-speed boat during planing. The pressure limits in the simulation are defined by employing a finite element model (FEM) that evaluates the forces applied by the cam that hits the panels in the apparatus via microdeformations obtained in the simulation. Th...

  17. Finite-density transition line for QCD with 695 MeV dynamical fermions

    Science.gov (United States)

    Greensite, Jeff; Höllwieser, Roman

    2018-06-01

    We apply the relative weights method to SU(3) gauge theory with staggered fermions of mass 695 MeV at a set of temperatures in the range 151 ≤T ≤267 MeV , to obtain an effective Polyakov line action at each temperature. We then apply a mean field method to search for phase transitions in the effective theory at finite densities. The result is a transition line in the plane of temperature and chemical potential, with an end point at high temperature, as expected, but also a second end point at a lower temperature. We cannot rule out the possibilities that a transition line reappears at temperatures lower than the range investigated, or that the second end point is absent for light quarks.

  18. Radiative cooling to deep sub-freezing temperatures through a 24-h day-night cycle

    Science.gov (United States)

    Chen, Zhen; Zhu, Linxiao; Raman, Aaswath; Fan, Shanhui

    2016-12-01

    Radiative cooling technology utilizes the atmospheric transparency window (8-13 μm) to passively dissipate heat from Earth into outer space (3 K). This technology has attracted broad interests from both fundamental sciences and real world applications, ranging from passive building cooling, renewable energy harvesting and passive refrigeration in arid regions. However, the temperature reduction experimentally demonstrated, thus far, has been relatively modest. Here we theoretically show that ultra-large temperature reduction for as much as 60 °C from ambient is achievable by using a selective thermal emitter and by eliminating parasitic thermal load, and experimentally demonstrate a temperature reduction that far exceeds previous works. In a populous area at sea level, we have achieved an average temperature reduction of 37 °C from the ambient air temperature through a 24-h day-night cycle, with a maximal reduction of 42 °C that occurs when the experimental set-up enclosing the emitter is exposed to peak solar irradiance.

  19. Radiative cooling to deep sub-freezing temperatures through a 24-h day-night cycle.

    Science.gov (United States)

    Chen, Zhen; Zhu, Linxiao; Raman, Aaswath; Fan, Shanhui

    2016-12-13

    Radiative cooling technology utilizes the atmospheric transparency window (8-13 μm) to passively dissipate heat from Earth into outer space (3 K). This technology has attracted broad interests from both fundamental sciences and real world applications, ranging from passive building cooling, renewable energy harvesting and passive refrigeration in arid regions. However, the temperature reduction experimentally demonstrated, thus far, has been relatively modest. Here we theoretically show that ultra-large temperature reduction for as much as 60 °C from ambient is achievable by using a selective thermal emitter and by eliminating parasitic thermal load, and experimentally demonstrate a temperature reduction that far exceeds previous works. In a populous area at sea level, we have achieved an average temperature reduction of 37 °C from the ambient air temperature through a 24-h day-night cycle, with a maximal reduction of 42 °C that occurs when the experimental set-up enclosing the emitter is exposed to peak solar irradiance.

  20. Quiet-time 0.04 - 2 MeV/nucleon Ions at 1 AU in Solar Cycles 23 and 24

    Science.gov (United States)

    Zeldovich, M. A.; Logachev, Y. I.; Kecskeméty, K.

    2018-01-01

    The fluxes of 3He, 4He, C, O, and Fe ions at low energies (about 0.04 - 2 MeV/nucleon) are studied during quiet periods in Solar Cycles (SC) 23 and 24 using data from the ULEIS/ACE instrument. In selecting quiet periods (the definition is given in Section 2.1), additional data from EPHIN/SOHO and EPAM/ACE were also used. The analysis of the ion energy spectra and their relative abundances shows that their behavior is governed by their first-ionization potential. Substantial differences in the ion energy spectra in two consecutive solar cycles are observed during the quiet periods selected. Quiet-time fluxes are divided into three distinct types according to the {˜} 80 - 320 keV/nucleon Fe/O ratio. Our results confirm the earlier observation that these types of suprathermal particles have different origins, that is, they represent different seed populations that are accelerated by different processes. Except for the solar activity minimum, the Fe/O ratio during quiet-time periods correspond either to the abundances of ions in particle fluxes accelerated in impulsive solar flares or to the mean abundances of elements in the solar corona. At the activity minimum, this ratio takes on values that are characteristic for the solar wind. These results indicate that the background fluxes of low-energy particles in the ascending, maximum, and decay phases of the solar cycle include significant contributions from both coronal particles accelerated to suprathermal energies and ions accelerated in small impulsive solar flares rich in Fe, while the contribution of remnants from earlier SEP events cannot be excluded. The comparison of suprathermal ion abundances during the first five years of SC 23 and SC 24 suggests that the quiet-time and non-quiet fluxes of Fe and 3He were lower in SC 24.

  1. MeCP2 regulates ethanol sensitivity and intake.

    Science.gov (United States)

    Repunte-Canonigo, Vez; Chen, Jihuan; Lefebvre, Celine; Kawamura, Tomoya; Kreifeldt, Max; Basson, Oan; Roberts, Amanda J; Sanna, Pietro Paolo

    2014-09-01

    We have investigated the expression of chromatin-regulating genes in the prefrontal cortex and in the shell subdivision of the nucleus accumbens during protracted withdrawal in mice with increased ethanol drinking after chronic intermittent ethanol (CIE) vapor exposure and in mice with a history of non-dependent drinking. We observed that the methyl-CpG binding protein 2 (MeCP2) was one of the few chromatin-regulating genes to be differentially regulated by a history of dependence. As MeCP2 has the potential of acting as a broad gene regulator, we investigated sensitivity to ethanol and ethanol drinking in MeCP2(308/) (Y) mice, which harbor a truncated MeCP2 allele but have a milder phenotype than MeCP2 null mice. We observed that MeCP2(308/) (Y) mice were more sensitive to ethanol's stimulatory and sedative effects than wild-type (WT) mice, drank less ethanol in a limited access 2 bottle choice paradigm and did not show increased drinking after induction of dependence with exposure to CIE vapors. Alcohol metabolism did not differ in MeCP2(308/) (Y) and WT mice. Additionally, MeCP2(308/) (Y) mice did not differ from WT mice in ethanol preference in a 24-hour paradigm nor in their intake of graded solutions of saccharin or quinine, suggesting that the MeCP2(308/) (Y) mutation did not alter taste function. Lastly, using the Gene Set Enrichment Analysis algorithm, we found a significant overlap in the genes regulated by alcohol and by MeCP2. Together, these results suggest that MeCP2 contributes to the regulation of ethanol sensitivity and drinking. © 2013 The Authors, Addiction Biology © 2013 Society for the Study of Addiction.

  2. Second Hagedorn temperature and glueball formation

    International Nuclear Information System (INIS)

    Dias de Deus, J.; Pimenta, M.

    1984-09-01

    We argue that confinement involving higher representations of SU(N) in singlet Ranti R bound states may occur at higher Hagedorn temperatures. The simplest possibility corresponds to the case when the binding potential is proportional to the quadratic Casimir Csub(R). The lowest Hagedorn temperature Tsub(H1) is the temperature for qanti q meson formation. The next, Tsub(H2), is the temperature for glueball hadronization. Higher representation Ranti R bound states are not likely to occur. The second Hagedorn temperature, separating the physics of hadrons from the physics of QCD plasma, plays the role of the deconfining temperature. Simple effective potential estimates give Tsub(H2)/Tsub(H1)approx.=(Csub(A)/Csub(F))sup(1/2)=3/2, in SU(3), with Tsub(H2)=395 MeV and Tsub(H1)=210 MeV, and for the glueball spin-averaged mass, μsub(G)=1370 MeV. Glueballs, in comparison with normal hadrons, are produced with larger psub(T) and larger multiplicities. (orig.)

  3. Nuclear shell effects at high temperatures

    International Nuclear Information System (INIS)

    Davidson, N.J.; Miller, H.G.

    1993-01-01

    In discussing the disappearance of nuclear shell effects at high temperatures, it is important to distinguish between the ''smearing out'' of the single-particle spectrum with increasing temperature and the vanishing of shell related structures in many-body quantities such as the excitation energy per nucleon. We propose a semiempirical method to obtain an upper bound on the temperature required to smooth the single-particle spectrum, and point out that shell effects in many-body parameters may persist above this temperature. We find that the temperature required to smear out the single-particle spectrum is approximately 1 MeV for heavy nuclei (A approx-gt 150) and about 3--4 MeV for light nuclei (A approx-lt 50), in reasonable agreement with the estimate of 41/πA 1/3 obtained from calculations with harmonic oscillator potentials. These temperatures correspond to many-body excitation energies of approximately 20 and 60 MeV, respectively

  4. Silk I and Silk II studied by fast scanning calorimetry

    Energy Technology Data Exchange (ETDEWEB)

    Cebe, Peggy; Partlow, Benjamin P.; Kaplan, David L.; Wurm, Andreas; Zhuravlev, Evgeny; Schick, Christoph

    2017-06-01

    Using fast scanning calorimetry (FSC), we investigated the glass transition and crystal melting of samples of B. mori silk fibroin containing Silk I and/or Silk II crystals. Due to the very short residence times at high temperatures during such measurements, thermal decomposition of silk protein can be significantly suppressed. FSC was performed at 2000 K/s using the Mettler Flash DSC1 on fibroin films with masses around 130–270 ng. Films were prepared with different crystalline fractions (ranging from 0.26 to 0.50) and with different crystal structures (Silk I, Silk II, or mixed) by varying the processing conditions. These included water annealing at different temperatures, exposure to 50% MeOH in water, or autoclaving. The resulting crystal structure was examined using wide angle X-ray scattering. Degree of crystallinity was evaluated from Fourier transform infrared (FTIR) spectroscopy and from analysis of the heat capacity increment at the glass transition temperature. Silk fibroin films prepared by water annealing at 25 °C were the least crystalline and had Silk I structure. FTIR and FSC studies showed that films prepared by autoclaving or 50% MeOH exposure were the most crystalline and had Silk II structure. Intermediate crystalline fraction and mixed Silk I/Silk II structures were found in films prepared by water annealing at 37 °C. FSC results indicate that Silk II crystals exhibit endotherms of narrower width and have higher mean melting temperature Tm(II) = 351 ± 2.6 °C, compared to Silk I crystals which melt at Tm(I) = 292 ± 3.8 °C. Films containing mixed Silk I/Silk II structure showed two clearly separated endothermic peaks. Evidence suggests that the two types of crystals melt separately and do not thermally interconvert on the extremely short time scale (0.065 s between onset and end of melting) of the FSC experiment.

  5. Variation law of gas holdup in an autoclave during the pressure leaching process by using a mixed-flow agitator

    Science.gov (United States)

    Tian, Lei; Liu, Yan; Tang, Jun-jie; Lü, Guo-zhi; Zhang, Ting-an

    2017-08-01

    The multiphase reaction process of pressure leaching is mainly carried out in the liquid phase. Therefore, gas holdup is essential for the gas-liquid-solid phase reaction and the extraction rate of valuable metals. In this paper, a transparent quartz autoclave, a six blades disc turbine-type agitator, and a high-speed camera were used to investigate the gas holdup of the pressure leaching process. Furthermore, experiments determining the effects of agitation rate, temperature, and oxygen partial pressure on gas holdup were carried out. The results showed that when the agitation rate increased from 350 to 600 r/min, the gas holdup increased from 0.10% to 0.64%. When the temperature increased from 363 to 423 K, the gas holdup increased from 0.14% to 0.20%. When the oxygen partial pressure increased from 0.1 to 0.8 MPa, the gas holdup increased from 0.13% to 0.19%. A similar criteria relationship was established by Homogeneous Principle and Buckingham's theorem. Comprehensively, empirical equation of gas holdup was deduced on the basis of experimental data and the similarity theory, where the criterion equation was determined as ɛ = 4.54 × 10-11 n 3.65 T 2.08 P g 0.18. It can be seen from the formula that agitation rate made the most important impact on gas holdup in the pressure leaching process using the mixed-flow agitator.

  6. Effects of temperature on SCC propagation in high temperature water injected with hydrogen peroxide

    International Nuclear Information System (INIS)

    Nakano, Junichi; Sato, Tomonori; Kato, Chiaki; Yoshiyuki, Kaji; Yamamoto, Masahiro; Tsukada, Takashi

    2012-09-01

    To understand the stress corrosion cracking (SCC) behaviour of austenitic stainless steels (SSs) in the boiling water reactor (BWR) coolant environment, it is significant to investigate the effect of hydrogen peroxide (H 2 O 2 ) produced by the radiolysis of water on SCC under the various water chemistry and operational conditions. At the start-up or shut-down periods, for example, the conditions of radiation and temperature on the structural materials are different from those during the plant normal operation, and may be influencing on SCC behaviour. Therefore, the effect of temperature on SCC in high temperature water injected with H 2 O 2 was evaluated by SCC propagation test at the present study. Oxide films on the metal surface in crack were examined and the thermal equilibrium diagram was calculated to estimate the environmental situation in the crack. On the thermally sensitized type 304 SS, crack growth tests were conducted in high temperature water injected with H 2 O 2 to simulate water radiolysis in the core. Small CT type specimens with a width of 15.5 mm and thickness of 6.2 mm were machined from the sensitized SS. SCC growth tests were conducted in high temperature water injected with 100 ppb H 2 O 2 at 453 and 561 K. To minimize H 2 O 2 decomposition by a contact with metal surface of autoclave, the CT specimen was isolated from inner surface of the autoclave by the inner modules made of polytetrafluoroethylene (PTFE), and PTFE lining was also used for the inner surface of inlet and sampling tubes. Base on the measurement of sampled water, it was confirmed that 80-90 % of injected H 2 O 2 remained around the CT specimen in autoclave. Constant load at initial K levels of 11-20 MPam 1/2 was applied to the CT specimens during crack growth tests. After crack growth tests, CT specimens were split into two pieces on the plane of crack propagation. Scanning electron microscope (SEM) examination and laser Raman spectroscopy for outer oxide layer of oxide

  7. Correlations of light particles in the reaction 40Ar on 197Au at E/A=200 MeV

    International Nuclear Information System (INIS)

    Kunde, G.J.

    1990-08-01

    For the study of small-angle correlations of light particles an experiment at the SATURNE synchrotron with 40 Ar on 197 Au at an incident energy of E/A=200 MeV was performed. A hodoscope consisting of an 8x8 matrix of silicon-cesium iodide detectors was applied under a mean angle of 40 degrees. The evaluation of the coincident particle information was performed via correlation functions, which were determined for systems with Z ≤ = 3. For three different fragments emission temperatures were measured via the determination of population ratios for particle-unstable states. Furthermore by means of p-p correlations the reaction volume was studied. The results are: For 5 Li a mean emission temperature of 6.4 -1.0 1.1 MeV resulted, for 4 He a mean emission temperature of 5.4 -1.2 +1.8 MeV was found. The temperature of 2.3 -0.2 0.6 MeV determined for 8 Be is strongly influenced by feeding. For the states at 21.1 and 22.1 MeV in 4 He a dependence of the temperature on the kinetic sum energy of the coincident particles was found, a temperature growth with increasing sum energy of about 3 MeV over the measured range of the sum energies resulted. Via p-p correlations a source radius of 5.8 ± 0.3 fm was determined. The correction for protons from sequential decays leads to radii, which are about 1 fm smaller. The radii and radius ratios for different ranges of the sum energy of the protons were analyzed. The measured emission temperatures are about 1 MeV higher than the values for the same system at E/A = 60 MeV. The temperatures correspond in the model of the statistical multifragmentation to an excitation energy of about 2 GeV, while they follow in the model of the sequential fragment emission for an excitation energy of about 1 GeV. (orig.) [de

  8. Investigation of the 24Mg(d, p)25Mg reaction

    NARCIS (Netherlands)

    Meurders, F.; Korte, G. de

    1975-01-01

    Abstract Proton angular distributions from the 24Mg(d, p)25Mg reaction at Ed = 12.0 MeV have been measured with a split-pole magnetic spectrograph for Ex < 6 MeV at an average resolution (FWHM) of 7 keV. New ln values have been determined for three levels. A DWBA analysis yielded spectroscopic

  9. High-Temperature Graphite/Phenolic Composite

    Science.gov (United States)

    Seal, Ellis C.; Bodepudi, Venu P.; Biggs, Robert W., Jr.; Cranston, John A.

    1995-01-01

    Graphite-fiber/phenolic-resin composite material retains relatively high strength and modulus of elasticity at temperatures as high as 1,000 degrees F. Costs only 5 to 20 percent as much as refractory materials. Fabrication composite includes curing process in which application of full autoclave pressure delayed until after phenolic resin gels. Curing process allows moisture to escape, so when composite subsequently heated in service, much less expansion of absorbed moisture and much less tendency toward delamination. Developed for nose cone of external fuel tank of Space Shuttle. Other potential aerospace applications for material include leading edges, parts of nozzles, parts of aircraft engines, and heat shields. Terrestrial and aerospace applications include structural firewalls and secondary structures in aircraft, spacecraft, and ships. Modified curing process adapted to composites of phenolic with other fiber reinforcements like glass or quartz. Useful as high-temperature circuit boards and electrical insulators.

  10. Pressure effects on high temperature steam oxidation of Zircaloy-4

    International Nuclear Information System (INIS)

    Park, Kwangheon; Kim, Kwangpyo; Ryu, Taegeun

    2000-01-01

    The pressure effects on Zircaloy-4 (Zry-4) cladding in high temperature steam have been analyzed. A double layer autoclave was made for the high pressure, high temperature oxidation tests. The experimental test temperature range was 700 - 900 deg C, and pressures were 0.1 - 15 MPa. Steam partial pressure turns out to be an important one rather than total pressure. Steam pressure enhances the oxidation rate of Zry-4 exponentially. The enhancement depends on the temperature, and the maximum exists between 750 - 800 deg C. Pre-existing oxide layer decreases the enhancement about 40 - 60%. The acceleration of oxidation rate by high pressure team seems to be originated from the formation of cracks by abrupt transformation of tetragonal phase in oxide, where the un-stability of tetragonal phase comes from the reduction of surface energy by steam. (author)

  11. High temperature dissolution of ferrites, chromites and bonaccordite in chelating media

    Energy Technology Data Exchange (ETDEWEB)

    Sathyaseelan, V.S.; Subramanian, H.; Anupkumar, B.; Rufus, A.L.; Velmurugan, S.; Narasimhan, S.V., E-mail: snv@igcar.gov.in [BARC Facilities, Water and Steam Chemistry Div., Tamilnadu (India)

    2010-07-01

    by the reagents used in chemical decontamination processes. Sample of bonaccordite was prepared by solid state route by heating stoichiometric mixtures of Hematite, Nickel Oxide and Boric acid at 900{sub o}C for 24 Hours. The phase purity of Bonaccordite formed was confirmed by XRD and Laser Raman Spectroscopy. Studies carried out in the Teflon lined autoclave indicated that boron and zinc containing oxides/ ferrites can be dissolved more easily at elevated temperatures (>140{sub o}C) as compared to normal temperatures (80 - 100{sub o}C). The effect of variation of temperature, concentration of chelating agent, presence of reducing agents has also been studied. High temperature corrosion study of carbon steel (CS) and stainless steel in all the above chelating medium in the presence and the absence of reductants has been carried out. About 60% reduction in corrosion rate was observed for CS in NTA medium in the presence of N{sub 2}H{sub 4} at 160{sup o}C and at pH 6.5. However, at the same temperature and pH, in the absence of N{sub 2}H{sub 4}, corrosion rate of CS was decreased drastically. With increase in temperature, dissolution rate of chromium oxide also increased considerably. The effectiveness of high temperature process was substantiated by using oxide covered specimen prepared under simulated BWR water chemistry conditions. (author)

  12. Spin reversal in Gd(Me,MnO3 (Me = Co, Ni

    Directory of Open Access Journals (Sweden)

    Gutiérrez, D.

    2004-06-01

    Full Text Available Partial substitution of the rare-earth by calcium at the cationic site of the ABO3 perovskites may show extraordinary effects of spin reversal due to a negative polarization between the rare-earth and the manganese networks, as it occurs in the solid solution Gd1‑xCaxMnO3. We present herein similar effects in gadolinium perovskites of the Gd(Me,MnO3 type, in which the manganese sublattice has been partially substituted by transition metal elements Me, leaving the gadolinium network intact. The spin reversal phenomena is observed at a critical concentration of x(Me = 1/3, which implies an optimum number of pairs Mn3+-Mn4+. Néel temperatures of 48 and 67 K are obtained for Me = Co and Ni, respectively, at the optimum concentration of substituent. A comparison between these different solid solutions allows us to generalize the interpretation of two interacting magnetic sublattices : a Mn-based ferromagnetic one and a negatively-aligned gadolinium network.La sustitución parcial del lantánido por el elemento calcio en el sitio catiónico (sitio A de la perovskita ABO3 puede dar lugar a efectos importantes ligados a una inversión del espín. Dicha inversión se debe a una interacción negativa entre la tierra rara y la subred de manganeso, tal como ocurre en la solución solida Gd1-xCaxMnO3. Se presentan en este trabajo efectos similares que ocurren en las perovskitas de gadolinio de fórmula Gd(Me,MnO3, en las cuales la subred de manganeso (sitio B ha sido reemplazada parcialmente por otros metales de transición Me, dejando intacta la subred de gadolinio. Se observa el fenómeno de inversión de espín para una concentración crítica x(Me = 1/3, para la cual se logra una cantidad óptima de pares Mn3+‑Mn4+. Para esta concentración crítica se observan temperaturas de Néel antiferromagnéticas del orden de 48 y 67 K, respectivamente para Me = Co y Ni. Un análisis comparativo entre estos diferentes sistemas permite generalizar la

  13. Three- α particle correlations in quasi-projectile decay in 12C + 24Mg collisions at 35A MeV

    Science.gov (United States)

    Quattrocchi, L.; Acosta, L.; Amorini, F.; Anzalone, A.; Auditore, L.; Berceanu, I.; Cardella, G.; Chbihi, A.; De Filippo, E.; De Luca, S.; Dell'Aquila, D.; Francalanza, L.; Gnoffo, B.; Grzeszczuk, A.; Lanzalone, G.; Lombardo, I.; Martel, I.; Martorana, N. S.; Minniti, T.; Norella, S.; Pagano, A.; Pagano, E. V.; Papa, M.; Pirrone, S.; Politi, G.; Porto, F.; Rizzo, F.; Rosato, E.; Russotto, P.; Trifirò, A.; Trimarchi, M.; Verde, G.; Veselsky, M.; Vigilante, M.

    2017-11-01

    Two and multi particle correlations have been studied in peripheral 12C + 24Mg collisions at 35A MeV with CHIMERA 4 π multi detector, in order to explore resonances produced in light nuclei. Correlations techniques have become a tool to explore nuclear structure properties but also to evaluate the competition between simultaneous and sequential channels in decay of light isotopes. The exploration of features such as branching ratios with respect to different decay channels (sequential vs. simultaneous) could provide information on in-medium effects on nuclear structure properties, an important perspective for research on the nuclear interaction. The performed experiment is preliminary to further studies to be performed by coupling of CHIMERA to FARCOS (Femtoscope ARray for COrrelations and Spectroscopy, FARCOS TDR available at https://drive.google.com/file/d/0B5CgGWz8LpOOc3pGTWdOcDBoWFE) array devoted to measurements of two and multi particle correlations with high energy and angular resolutions.

  14. Study of heavy ion fusion reaction of 58Ni + 24Mg at 11 MeV/nucleon

    International Nuclear Information System (INIS)

    Shea, J.Y.

    1991-01-01

    This thesis presents a study of the heavy ion fusion reaction in which a 58 Ni projectile bombards a 24 Mg target at 11 MeV/nucleon. The incident projectile energy was purposefully chosen so as the system studied to be at the onset of the more complex and interesting phenomenon of incomplete fusion. The physics motivation is to probe the central collision of a heavy, energetic, and asymmetric system by means of both inclusive and exclusive experimental measurements. The experiment was performed at HHIRF (Holifield Heavy Ion Research Facility) by using the coupled accelerators at Oak Ridge National Laboratory. The reaction products were measured by the new open-quotes HILI-Ringclose quotes large solid angle detector system at Oak Ridge National Laboratory. The thesis discusses the physics motivation and the systematics of heavy ion fusion reactions. Details of the design and construction of a new CsI(T1) Ring detector is given. Since this is the first such study performed on the Heavy Ion Light Ion (HILI) detector, an extensive discussion of the calibration procedures and the data reduction methods are given. The fusion reaction data were analyzed in both inclusive and exclusive modes with the result that a valuable new perspective on the deconvolution of the reaction mechanism has been achieved

  15. Effect of Xe ion (167 MeV) irradiation on polycrystalline SiC implanted with Kr and Xe at room temperature

    International Nuclear Information System (INIS)

    Hlatshwayo, T T; Kuhudzai, R J; Njoroge, E G; Malherbe, J B; O’Connell, J H; Skuratov, V A; Msimanga, M

    2015-01-01

    The effect of swift heavy ion (Xe 167 MeV) irradiation on polycrystalline SiC individually implanted with 360 keV Kr and Xe ions at room temperature to fluences of 2  ×  10 16 cm −2 and 1  ×  10 16 cm −2 respectively, was investigated using transmission electron microscopy (TEM), Raman spectroscopy and Rutherford backscattering spectrometry (RBS). Implanted specimens were each irradiated with 167 MeV Xe +26 ions to a fluence of 8.3  ×  10 14 cm −2 at room temperature. It was observed that implantation of 360 keV Kr and Xe ions individually at room temperature amorphized the SiC from the surface up to a depth of 186 and 219 nm respectively. Swift heavy ion (SHI) irradiation reduced the amorphous layer by about 27 nm and 30 nm for the Kr and Xe samples respectively. Interestingly, the reduction in the amorphous layer was accompanied by the appearance of randomly oriented nanocrystals in the former amorphous layers after SHI irradiation in both samples. Previously, no similar nanocrystals were observed after SHI irradiations at electron stopping powers of 33 keV nm −1 and 20 keV nm −1 to fluences below 10 14 cm −2 . Therefore, our results suggest a fluence threshold for the formation of nanocrystals in the initial amorphous SiC after SHI irradiation. Raman results also indicated some annealing of radiation damage after swift heavy ion irradiation and the subsequent formation of small SiC crystals in the amorphous layers. No diffusion of implanted Kr and Xe was observed after swift heavy ion irradiation. (paper)

  16. Study of the thermal oxidation of titanium and zirconium under argon ion irradiation in the low MeV range (E = 15 MeV)

    International Nuclear Information System (INIS)

    Do, N.-L.

    2012-01-01

    We have shown that argon ion irradiation between 1 and 15 MeV produces damage on both titanium and zirconium surfaces, taking the form of accelerated oxidation and/or craterization effects, varying as a function of the projectile energy and the annealing atmosphere (temperature and pressure) simulating the environmental conditions of the fuel/cladding interface of PWR fuel rods. Using AFM, we have shown that the titanium and zirconium surface is attacked under light argon ion bombardment at high temperature (up to 500 C) in weakly oxidizing medium (under rarefied dry air pressure ranging from 5,7 10 -5 Pa to 5 10 -3 Pa) for a fixed fluence of about 5 10 14 ions.cm -2 . We observed the formation of nano-metric craters over the whole titanium surface irradiated between 2 and 9 MeV and the whole zirconium surface irradiated at 4 MeV, the characteristics of which vary depending on the temperature and the pressure. In the case of the Ar/Ti couple, the superficial damage efficiency increases when the projectile energy decreases from 9 to 2 MeV. Moreover, whereas the titanium surface seems to be transparent under the 15-MeV ion beam, the zirconium surface exhibits numerous micrometric craters surrounded by a wide halo. The crater characteristics (size and superficial density) differ significantly from that observed both in the low energy range (keV) where the energy losses are controlled by ballistic collisions (Sn) and in the high energy range (MeV - GeV) where the energy losses are controlled by electronic excitations (Se), which was not completely unexpected in this intermediate energy range for which combined Sn - Se stopping power effects are possibly foreseen. Using XPS associated to ionic sputtering, we have shown that there is an irradiation effect on thermal oxidation of titanium, enhanced under the argon ion beam between 2 and 9 MeV, and that there is also an energy effect on the oxide thickness and stoichiometry. The study conducted using Spectroscopic

  17. Low temperature irradiation of iron, zirconium and copper by 10 to 16 MeV protons

    Energy Technology Data Exchange (ETDEWEB)

    Omar, A M

    1978-01-01

    A theoretical analysis of scattering and radiation damage parameters is carried out for 14 MeV neutrons and 10-17 MeV protons on Fe, Ni, Cu, Zr, Nb, and Au. Damage energies are computed for the interactions using both elastic and non-elastic data. The results show that proton encounters deposit a greater damage energy than 14 MeV neutrons. To examine the theoretical results, electrical resistivity measurements are undertaken for Fe, Zr and Cu irradiated at 12 to 17.5K with 10 to 16 MeV protons. Post-irradiation annealing is carried out in situ using a closed-cycle helium-cooled cryostat. Values of the resistivity damage rate are compared with values estimated from the theoretical damage-energy results. Also, the observed stage I recovery is analysed in terms of the corresponding recovery reported for electron and fast-neutron irradiations. The relation between the 16 MeV proton data and published data estimated from a fusion reactor spectrum is discussed. It is also shown that protons create a damage structure similar to a superposition of the damage structures generated by electrons and fast neutrons. The sample state of imperfection is shown to influence the induced damage state in proton irradiation.

  18. Giant quadrupole resonance in 12C, 24Mg, and 27Al observed via deuteron inelastic scattering

    International Nuclear Information System (INIS)

    Chang, C.C.; Didelez, J.P.; Kwiatowski, K.; Wo, J.R.

    1977-06-01

    Giant quadrupole resonance in 12 C, 24 Mg, and 27 Al was studied using 70 MeV deuteron beam. The results clearly show, in all three targets, resonance-like structures peaked at E/sub x/ approximately 63A/sup -1/3/ MeV, with a width of about 10 MeV. The experimental angular distributions for these resonances agree well with the l = 2 DWBA prediction. For 12 C, a binary splitting was observed, and for 24 Mg, there are indications of finer structure in the main giant quadrupole resonance region

  19. Impacts of sporulation temperature, exposure to compost matrix and temperature on survival of Bacillus cereus spores during livestock mortality composting.

    Science.gov (United States)

    Stanford, K; Reuter, T; Gilroyed, B H; McAllister, T A

    2015-04-01

    To investigate impact of sporulation and compost temperatures on feasibility of composting for disposal of carcasses contaminated with Bacillus anthracis. Two strains of B. cereus, 805 and 1391, were sporulated at either 20 or 37°C (Sporulation temperature, ST) and 7 Log10 CFU g(-1) spores added to autoclaved manure in nylon bags (pore size 50 μm) or in sealed vials. Vials and nylon bags were embedded into compost in either a sawdust or manure matrix each containing 16 bovine mortalities (average weight 617 ± 33 kg), retrieved from compost at intervals over 217 days and survival of B. cereus spores assessed. A ST of 20°C decreased spore survival by 1·4 log10 CFU g(-1) (P Compost temperatures >55°C reduced spore survival (P compost temperatures were key factors influencing survival of B. cereus spores in mortality compost. Composting may be most appropriate for the disposal of carcasses infected with B. anthracis at ambient temperatures ≤20°C under thermophillic composting conditions (>55°C). © 2015 The Society for Applied Microbiology.

  20. Activation of SO2 with [(η(5) -C5 Me5 )2 Ln(THF)2 ] (Ln=Eu, Yb) leading to dithionite and sulfinate complexes.

    Science.gov (United States)

    Klementyeva, Svetlana V; Gamer, Michael T; Schmidt, Anna-Corina; Meyer, Karsten; Konchenko, Sergey N; Roesky, Peter W

    2014-10-13

    The reaction of decamethylytterbocene [(η(5) -C5 Me5 )2 Yb(THF)2 ] with SO2 at low temperature gave two new compounds, namely, the Yb(III) dithionite/sulfinate complex [{(η(5) -C5 Me5 )2 Yb(μ3 ,1κ(2) O(1,3) ,2κ(3) O(2,2',4) -S2 O4 )}2 {(η(5) -C5 Me5 )Yb(μ,1κO,2κO'-C5 Me5 SO2 )}2 ] (1) and the Yb(III) dithionite complex [{(η(5) -C5 Me5 )2 Yb}2 (μ,1κ(2) O(1,3) ,2κ(2) O(2,4) -S2 O4 )] (2). After extraction of 1, the mixture was heated to give the dinuclear tetrasulfinate complex [{(η(5) -C5 Me5 )Yb}2 (μ,κO,κO'-C5 Me5 SO2 )4 ] (3 a). In contrast, from the reaction of [(η(5) -C5 Me5 )2 Eu(THF)2 ] with SO2 only the tetrasulfinate complex [{(η(5) -C5 Me5 )Eu}2 (μ,κO,κO'-C5 Me5 SO2 )4 ] (3 b) was isolated. Two major reaction pathways were observed: 1) reductive coupling of two SO2 molecules to form the dithionite anion S2 O4 (2-) ; and 2) nucleophilic attack of one metallocene C5 Me5 ligand on the sulfur atom of SO2 . The compounds presented are the first dithionite and sulfinate complexes of the f-elements. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Antimicrobial activity of Hibiscus sabdariffa aqueous extracts against Escherichia coli O157:H7 and Staphylococcus aureus in a microbiological medium and milk of various fat concentrations.

    Science.gov (United States)

    Higginbotham, Kristen L; Burris, Kellie P; Zivanovic, Svetlana; Davidson, P Michael; Stewart, C Neal

    2014-02-01

    Hibiscus sabdariffa L. calyces are widely used in the preparation of beverages. The calyces contain compounds that exhibit antimicrobial activity, yet little research has been conducted on their possible use in food systems as antimicrobials. Aqueous extracts prepared from the brand "Mi Costenita" were sterilized by membrane filtration (0.22-μm pore size) or autoclaving (121 °C, 30 min) and tested for antimicrobial activity against the foodborne pathogens Escherichia coli O157:H7 strains ATCC 43894 and Cider and Staphylococcus aureus strains SA113 and ATCC 27708 in a microbiological medium and ultrahigh-temperature-processed milk with various fat percentages. Extracts heated by autoclaving exhibited greater activity than did filtered extracts in a microbiological medium. Against E. coli, results of 20 mg/ml filtered extract were not different from those of the control, whereas autoclaved extracts reduced viable cells ca. 3 to 4 log CFU/ml. At 60 mg/ml, both extracts inactivated cells after 24 h. There were reduced populations of both strains of S. aureus (ca. 2.7 and 3 log CFU/ml, respectively) after 24 h of incubation in 40 mg/ml filtered extracts. When grown in autoclaved extracts at 40 mg/ml, both strains of S. aureus were inactivated after 9 h. Autoclaved extracts had decreased anthocyanin content (2.63 mg/liter) compared with filtered extracts (14.27 mg/liter), whereas the phenolic content (48.7 and 53.8 mg/g) remained similar for both treatments. Autoclaved extracts were then tested for activity in milk at various fat concentrations (skim [3.25%]) against a 1:1 mixture of the two strains of E. coli O157:H7 and a 1:1 mixture of the two strains of S. aureus. Extracts at 40 mg/ml inactivated S. aureus after 168 h in skim and whole milk, and E. coli was inactivated after 96 h in 60 mg/ml extract in all fat levels. These findings show the potential use of Hibiscus extracts to prevent the growth of pathogens in foods and beverages.

  2. RBS studies of the lattice damage caused by 1 MeV Si+ implantation into Al0.3Ga0.7As/GaAs superlattices at elevated temperature

    International Nuclear Information System (INIS)

    Xu Tianbing; Zhu Peiran; Zhou Junsi; Li Daiqing; Gong Baoan; Wan Ya; Mu Shanming; Zhao Qingtai; Wang Zhonglie

    1994-01-01

    The lattice damage accumulation in GaAs and Al 0.3 Ga 0.7 As/GaAs superlattices by 1 MeV Si + irradiation at room temperature and 350 C has been studied. For irradiations at 350 C, at lower doses the samples were almost defect-free after irradiation, while a large density of accumulated defects was induced at a higher dose. The critical dose above which the damage accumulation is more efficient is estimated to be 2 x 10 15 Si/cm 2 for GaAs, and is 5 x 10 15 Si/cm 2 for Al 0.8 Ga 0.7 As/GaAs superlattice for implantation with 1.0 MeV Si ions at 350 C. The damage accumulation rate for 1 MeV Si ion implantation in Al 0.3 Ga 0.7 As/GaAs superlattice is less than that in GaAs. (orig.)

  3. Development and Substantiation of Parameters of Environmentally Friendly Technology for Filling the Vertical Mine Workings with Autoclaved Slag-Concrete

    Directory of Open Access Journals (Sweden)

    Uglyanitca Andrey

    2017-01-01

    Full Text Available The environmentally friendly technology for filling the vertical mine workings with autoclaved slag-concrete, prefabricated on the surface of the mine is presented in the article; the optimal parameters of filling technology are proposed. The developed technology for filling the abandoned vertical mine workings allows ensuring the environmental safety of the territories adjacent to the abandoned mine, utilizing slag dumps and providing the possibility of shaft recovery, if necessary, with minimal labor and material costs.

  4. Transport anisotropy and electron correlations in the layered molecular compounds Z [Pd(dmit)2] 2 (Z =Me4N ,Et2Me2As ,EtMe3P ) with different interlayer coupling

    Science.gov (United States)

    Shimizu, Yasuhiro; Kato, Reizo

    2018-03-01

    In-plane resistivity ρ∥ and out-of-plane resistivity ρ⊥ were investigated across the pressure-induced Mott transition in molecular Mott insulators Z [Pd(dmit)2] 2 (Z =Et2Me2As , Me4N , and EtMe3P ) having a triangular lattice. All three compounds exhibit superconducting transition with Tc=5.5 -7.0 K in the metallic phase near the Mott insulating phase. For the β'-Et2Me2As salt, the anisotropy ρ⊥/ρ∥ exceeds 103 at low temperatures, indicating a highly two-dimensional electronic state with incoherent interlayer hopping. The β -Me4N salt has a smaller ρ⊥/ρ∥ exhibiting a weak interlayer coupling. The resistivity is dominated by electron-electron scattering in the metallic state for these two compounds, as expected in a correlated Fermi liquid. On the other hand, the EtMe3P salt with a valence bond order state becomes a nearly three-dimensional metal across the Mott transition, in which the electron correlation is strongly suppressed. Instead, the electron-phonon scattering plays a significant role in the resistivity. The different interlayer coherence is quantitatively explained by the calculated interlayer transfer integrals between Pd (dmit) 2 molecules. These results suggest that the dimensionality governs the nature of electron correlations in the Fermi liquid state.

  5. Note: CO₂-mineral dissolution experiments using a rocking autoclave and a novel titanium reaction cell.

    Science.gov (United States)

    Purser, Gemma; Rochelle, Christopher A; Wallis, Humphrey C; Rosenqvist, Jörgen; Kilpatrick, Andrew D; Yardley, Bruce W D

    2014-08-01

    A novel titanium reaction cell has been constructed for the study of water-rock-CO2 reactions. The reaction cell has been used within a direct-sampling rocking autoclave and offers certain advantages over traditional "flexible gold/titanium cell" approaches. The main advantage is robustness, as flexible cells are prone to rupture on depressurisation during gas-rich experiments. The reaction cell was tested in experiments during an inter-laboratory comparison study, in which mineral kinetic data were determined. The cell performed well during experiments up to 130 °C and 300 bars pressure. The data obtained were similar to those of other laboratories participating in the study, and also to previously published data.

  6. Hot nuclei, limiting temperatures and excitation energies

    International Nuclear Information System (INIS)

    Peter, J.

    1986-09-01

    Hot fusion nuclei are produced in heavy ion collisions at intermediate energies (20-100 MeV/U). Information on the maximum excitation energy per nucleon -and temperatures- indicated by the experimental data is compared to the predictions of static and dynamical calculations. Temperatures around 5-6 MeV are reached and seem to be the limit of formation of thermally equilibrated fusion nuclei

  7. The Effect of Autoclave Sterilization on Resistance to Cyclic Fatigue of Hero Endodontic File #642 (6%) at Two Artificial Curvature.

    Science.gov (United States)

    Khabiri, Masoud; Ebrahimi, Maziar; Saei, Mohammad Reza

    2017-12-01

    File fracture can interfere with cleaning and shaping of the canal and compromise periradicular healing. Autoclave sterilization may prone the files to fracture. The purpose of the present study was to determine the effect of autoclave sterilization on the cyclic fatigue resistance of Hero642 rotary instrument in two curvatures of 45 and 60 degrees. For this experimental in-vitro study, 90 Nickel-Titanium HERO 642 rotary files #30 with 0.06 taper were selected. They were divided into two groups (curvature of 45 and 60 degree) of 45 files. Each group was then subdivided into 3 subgroups; group I: no sterilization, group II: 5 cycles of sterilization and group III: 10 cycles of sterilization. Files were used in artificial canals until fracture. The cyclic fatigue was measured as the number of cycles before fracture. The data was statically analyzed by Student's t-test and two-way analysis of variance. There was a significant difference in cyclic fatigue of two curvature of 45 and 60 degrees ( p = 0.001). However, sterilization process has no significant effect on cyclic fatigue of HERO files ( p = 0.557). Sterilization had no effect on the cyclic fatigue of HERO 642 files when used in curvature of 45 or 60 degrees.

  8. Out-of-autoclave manufacturing of a stiffened thermoplastic carbon fibre PEEK panel

    Science.gov (United States)

    Flanagan, M.; Goggins, J.; Doyle, A.; Weafer, B.; Ward, M.; Bizeul, M.; Canavan, R.; O'Bradaigh, C.; Doyle, K.; Harrison, N.

    2017-10-01

    Out-of-Autoclave manufacturing methods, specifically Automated Tape Placement (ATP) and induction welding, used in the fabrication of a stiffened thermoplastic demonstrator panel, are presented in this study. The demonstrator panel consists of two stiffeners induction welded to a flat skin, to form a typical load bearing aerospace sub-component. The skin of the panel is manufactured from uni-directional Carbon Fibre (CF) Polyetheretherkeytone (PEEK) using laser assisted Automated Tape Placement (ATP) and the stiffeners are press formed from woven CF-PEEK. The stiffeners are fusion bonded to the skin using a continuous induction welding process. A susceptor material is used at the interface to ensure the required heating is concentrated at the weldline. Microscopy was used to examine the manufactured coupons for defects. Destructive testing was carried out to evaluate the strength of the overall assembly. The work shows that assemblies manufactured using continuous induction welding and ATP are suitable for load bearing aerospace applications.

  9. Characterization of polymer composites during autoclave manufacturing by Fourier transform Raman spectroscopy

    Science.gov (United States)

    Farquharson, Stuart; Smith, Wayne W.; Rigas, Elias J.; Granville, Dana

    2001-02-01

    12 The superior engineering properties of fiber reinforced polymer matrix composites, primarily the high strength-to- weight ratio, make them suitable to applications ranging from sporting goods to aircraft components (e.g. helicopter blades). Unfortunately, consistent fabrication of components with desired mechanical properties has proven difficult, and has led to high production costs. This is largely due to the inability to monitor and control polymer cure, loosely defined as the process of polymer chain extension and cross- linking. Even with stringent process control, slight variations in the pre-polymer formulations (e.g. prepreg) can influence reaction rates, reaction mechanisms, and ultimately, product properties. In an effort to optimize the performance of thermoset composite, we have integrated fiber optic probes between the plies of laminates and monitored cure by Raman spectroscopy, with the eventual goal of process control. Here we present real-time measurements of two high performance aerospace companies cured within an industrial autoclave.

  10. Evidence for a resonant behaviour in e+e- annihilation into hadrons, around 1820 MeV, at Adone

    International Nuclear Information System (INIS)

    Bacci, C.; Zorzi, G. de; Penso, G.; Stella, B.; Baldini-Celio, R.; Capon, G.; Fabbro, R. del; Iarocci, E.; Murtas, G.P.; Spinetti, M.

    1977-01-01

    Multihadron production has been measured at the Adone e + e - storage ring in the c.m. energy region 1600/1900 MeV. A resonant behaviour is observed, centered at 1819 +- 5 (+-2) MeV, with a width of 24 +-5 (+-4) MeV. This effect is observed only in the events with 3 or 4 charged particles together with photons, but not in those without photons. (Auth.)

  11. The Temperature-Density Relation in the Intergalactic Medium at Redshift langzrang = 2.4

    Science.gov (United States)

    Rudie, Gwen C.; Steidel, Charles C.; Pettini, Max

    2012-10-01

    We present new measurements of the temperature-density (T-ρ) relation for neutral hydrogen in the 2.0 law index of (Γ - 1) = 0.15 ± 0.02. Using analytic arguments, these measurements imply an "equation of state" for the IGM at langzrang = 2.4 of the form T=T_0 \\left(\\rho /\\bar{\\rho }\\right)^{\\gamma -1} with a temperature at mean density of T 0 = [1.94 ± 0.05] × 104 K and a power-law index (γ - 1) = 0.46 ± 0.05. Based on data obtained at the W. M. Keck Observatory, which is operated as a scientific partnership among the California Institute of Technology, the University of California, and the National Aeronautics and Space Administration, and was made possible by the generous financial support of the W. M. Keck Foundation.

  12. A survey of new temperature-sensitive, embryonic-lethal mutations in C. elegans: 24 alleles of thirteen genes.

    Directory of Open Access Journals (Sweden)

    Sean M O'Rourke

    2011-03-01

    Full Text Available To study essential maternal gene requirements in the early C. elegans embryo, we have screened for temperature-sensitive, embryonic lethal mutations in an effort to bypass essential zygotic requirements for such genes during larval and adult germline development. With conditional alleles, multiple essential requirements can be examined by shifting at different times from the permissive temperature of 15°C to the restrictive temperature of 26°C. Here we describe 24 conditional mutations that affect 13 different loci and report the identity of the gene mutations responsible for the conditional lethality in 22 of the mutants. All but four are mis-sense mutations, with two mutations affecting splice sites, another creating an in-frame deletion, and one creating a premature stop codon. Almost all of the mis-sense mutations affect residues conserved in orthologs, and thus may be useful for engineering conditional mutations in other organisms. We find that 62% of the mutants display additional phenotypes when shifted to the restrictive temperature as L1 larvae, in addition to causing embryonic lethality after L4 upshifts. Remarkably, we also found that 13 out of the 24 mutations appear to be fast-acting, making them particularly useful for careful dissection of multiple essential requirements. Our findings highlight the value of C. elegans for identifying useful temperature-sensitive mutations in essential genes, and provide new insights into the requirements for some of the affected loci.

  13. 17O(n,α)14C cross section from 25 meV to approximately 1 MeV

    International Nuclear Information System (INIS)

    Koehler, P.E.; Graff, S.M.

    1991-01-01

    We have measured the 17 O(n,α) 14 C cross section from thermal energy to approximately 1 MeV. A bump in the data near 3 keV could be fitted by a state whose properties are consistent with a known subthreshold J π =1 - level at E x =8.039 MeV. The cause of the 1/v cross section near thermal energy could not be determined although the known 2 + state at 8.213 MeV was found to be too narrow to contribute much to the thermal cross section. Our data are compared to measurements made via the inverse reaction. There are many differences between the two sets of data. The astrophysical reaction rate was calculated from the measured cross section. This reaction plays a role in the nucleosynthesis of heavy elements in nonstandard big-bang models. At big-bang temperatures, the experimental rate was found to be in fair agreement with the rate estimated from the previously known properties of states of 18 O in this region. Furthermore, using the available information from experiments, it was estimated that the 17 O(n,α) 14 C rate is approximately a factor of 10 3 --10 4 times larger than the 17 O(n,γ) 18 O rate at big-bang temperatures. As a result, there may be significant cycling between 14 C and 17 O resulting in a reduction of heavy-element nucleosynthesis

  14. Experimental evaluation on the influence of autoclave sterilization on the cyclic fatigue of new nickel-titanium rotary instruments.

    Science.gov (United States)

    Plotino, Gianluca; Costanzo, Alberto; Grande, Nicola M; Petrovic, Renata; Testarelli, Luca; Gambarini, Gianluca

    2012-02-01

    The purpose of this study was to evaluate the effect of autoclave sterilization on cyclic fatigue resistance of rotary endodontic instruments made of traditional and new nickel-titanium (NiTi) alloys. Four NiTi rotary endodontic instruments of the same size (tip diameter 0.40 mm and constant .04 taper) were selected: K3, Mtwo, Vortex, and K3 XF prototypes. Each group was then divided into 2 subgroups, unsterilized instruments and sterilized instruments. The sterilized instruments were subjected to 10 cycles of autoclave sterilization. Twelve files from each different subgroup were tested for cyclic fatigue resistance. Means and standard deviations of number of cycles to failure (NCF) and fragment length of the fractured tip were calculated for each group, and data were statistically analyzed (P instruments for each type of file, differences were statistically significant (P instruments did not show significant differences (P > .05) in the mean NCF as a result of sterilization cycles (K3, 424 versus 439 NCF; Mtwo, 409 versus 419 NCF; Vortex, 454 versus 480 NCF). Comparing the results among the different groups, K3 XF (either sterilized or not) showed a mean NCF significantly higher than all other files (P endodontic instruments except for the K3 XF prototypes of rotary instruments that demonstrated a significant increase of cyclic fatigue resistance. Copyright © 2012 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  15. Searching for multifragmentation in light asymmetric systems 93Nb+24Mg and 93Nb+27Al at 30 A.MeV

    International Nuclear Information System (INIS)

    Manduci, Loredana

    2004-01-01

    The present work analyses the inverse kinematics reactions 93 Nb+ 27 Al and 93 Nb+ 24 Mg at 30 A.MeV. The reaction events are sorted as a function of the violence of the collision and experimental sources are reconstructed. Their decay is studied by two statistical model simulations: Gemini, for binary sequential decay and SMM for prompt multifragmentation. Both models show a reasonable agreement with the experimental observables starting from a backtracking simulated source decay which has charge and excitation energy distributions comparable to the experimental ones. This result was expected because we are still under the multifragmentation onset. However both models disagree in the fragments production rate. This states the question on the different starting point for the fragment decay probability widths calculations altogether to the idea that taking into account the nuclear dynamics between the saddle-point and the scission point would improve our results. (author) [fr

  16. Irradiation effects of 11 MeV protons on ferritic steels

    International Nuclear Information System (INIS)

    Hamaguchi, Yoshikazu; Kuwano, Hisashi; Misawa, Toshihei

    1985-01-01

    It is considered that ferritic/martensitic steels are the candidate of the first wall materials for future fusion reactors. The most serious problem in the candidate materials is the loss of ductility due to the elevation of ductile-brittle transition temperature by the high dpa irradiation of neutrons. 14 MeV neutrons produced by D-T reaction cause high dpa damage and also produce large quantity of helium and hydrogen atoms in first wall materials. Those gas atoms also play an important role in the embrittlement of steels. The main purpose of this work was to simulate the behavior of hydrogen produced by the transmutation in the mechanical properties of ferritic steels when they were irradiated with 11 MeV protons. The experimental procedure and the results of hardness, the broadening of x-ray diffraction lines, Moessbauer spectroscopy and small punch test are reported. High energy protons of 10 - 20 MeV are suitable to the simulation experiment of 14 MeV neutron radiation damage. But the production of the active nuclei emitting high energy gamma ray and having long life, Co-56, is the most serious problem. Another difficulty is the control of irradiation temperature. A small irradiation chamber must be developed. (Kako, I.)

  17. The corrosion behavior of hafnium in high-temperature-water environments

    Energy Technology Data Exchange (ETDEWEB)

    Rishel, D.M.; Smee, J.D.; Kammenzind, B.F.

    1999-10-01

    The high-temperature-water corrosion performance of hafnium is evaluated. Corrosion kinetic data are used to develop correlations that are a function of time and temperature. The evaluation is based on corrosion tests conducted in out-of-pile autoclaves and in out-of-flux locations of the Advanced Test Reactor (ATR) at temperatures ranging from 288 to 360 C. Similar to the corrosion behavior of unalloyed zirconium, the high-temperature-water corrosion response of hafnium exhibits three corrosion regimes: pretransition, posttransition, and spalling. In the pretransition regime, cubic corrosion kinetics are exhibited, whereas in the posttransition regime, linear corrosion kinetics are exhibited. Because of the scatter in the spalling regime data, it is not reasonable to use a best fit of the data to describe spalling regime corrosion. Data also show that neutron irradiation does not alter the corrosion performance of hafnium. Finally, the data illustrate that the corrosion rate of hafnium is significantly less than that of Zircaloy-2 and Zircaloy-4.

  18. Insitu measurement and control of processing properties of composite resins in a production tool

    Science.gov (United States)

    Kranbuehl, D.; Hoff, M.; Haverty, P.; Loos, A.; Freeman, T.

    1988-01-01

    An in situ measuring technique for use in automated composite processing and quality control is discussed. Frequency dependent electromagnetic sensors are used to measure processing parameters at four ply positions inside a thick section 192-ply graphite-epoxy composite during cure in an 8 x 4 in. autoclave. Viscosity measurements obtained using the sensors are compared with the viscosities calculated using the Loos-Springer cure process model. Good overall agreement is obtained. In a subsequent autoclave run, the output from the four sensors was used to control the autoclave temperature. Using the 'closed loop' sensor controlled autoclave temperature resulted in a more uniform and more rapid cure cycle.

  19. A pilot-scale steam autoclave system for treating municipal solid waste for recovery of renewable organic content: Operational results and energy usage.

    Science.gov (United States)

    Holtman, Kevin M; Bozzi, David V; Franqui-Villanueva, Diana; Offeman, Richard D; Orts, William J

    2016-05-01

    A pilot-scale (1800 kg per batch capacity) autoclave used in this study reduces municipal solid waste to a debris contaminated pulp product that is efficiently separated into its renewable organic content and non-renewable organic content fractions using a rotary trommel screen. The renewable organic content can be recovered at nearly 90% efficiency and the trommel rejects are also much easier to sort for recovery. This study provides the evaluation of autoclave operation, including mass and energy balances for the purpose of integration into organic diversion systems. Several methods of cooking municipal solid waste were explored from indirect oil heating only, a combination of oil and direct steam during the same cooking cycle, and steam only. Gross energy requirements averaged 1290 kJ kg(-1) material in vessel, including the weight of free water and steam added during heating. On average, steam recovery can recoup 43% of the water added and 30% of the energy, supplying on average 40% of steam requirements for the next cook. Steam recycle from one vessel to the next can reduce gross energy requirements to an average of 790 kJ kg(-1). © The Author(s) 2016.

  20. Effect of MeJA treatment on polyamine, energy status and anthracnose rot of loquat fruit.

    Science.gov (United States)

    Cao, Shifeng; Cai, Yuting; Yang, Zhenfeng; Joyce, Daryl C; Zheng, Yonghua

    2014-02-15

    The effect of methyl jasmonate (MeJA) on changes in polyamines content and energy status and their relation to disease resistance was investigated. Freshly harvested loquat fruit were treated with 10 μmol l(-1) MeJA and wound inoculated with Colletotrichum acutatum spore suspension (1.0 × 10(5) spores ml(-1)) after 24h, and then stored at 20 °C for 6 days. MeJA treatment significantly reduced decay incidence. MeJA treated fruit manifested higher contents of polyamines (putrescine, spermidine and spermine) compared with the control fruit, during storage. MeJA treatment also maintained higher levels of adenosine triphosphate, and suppressed an increase in adenosine monophosphate content in loquat fruit. These results suggest that MeJA treatment may inhibit anthracnose rot by increasing polyamine content and maintaining the energy status. Copyright © 2013. Published by Elsevier Ltd.

  1. Escherichia coli K-12 survives anaerobic exposure at pH 2 without RpoS, Gad, or hydrogenases, but shows sensitivity to autoclaved broth products.

    Directory of Open Access Journals (Sweden)

    Daniel P Riggins

    Full Text Available Escherichia coli and other enteric bacteria survive exposure to extreme acid (pH 2 or lower in gastric fluid. Aerated cultures survive via regulons expressing glutamate decarboxylase (Gad, activated by RpoS, cyclopropane fatty acid synthase (Cfa and others. But extreme-acid survival is rarely tested under low oxygen, a condition found in the stomach and the intestinal tract. We observed survival of E. coli K-12 W3110 at pH 1.2-pH 2.0, conducting all manipulations (overnight culture at pH 5.5, extreme-acid exposure, dilution and plating in a glove box excluding oxygen (10% H2, 5% CO2, balance N2. With dissolved O2 concentrations maintained below 6 µM, survival at pH 2 required Cfa but did not require GadC, RpoS, or hydrogenases. Extreme-acid survival in broth (containing tryptone and yeast extract was diminished in media that had been autoclaved compared to media that had been filtered. The effect of autoclaved media on extreme-acid survival was most pronounced when oxygen was excluded. Exposure to H2O2 during extreme-acid treatment increased the death rate slightly for W3110 and to a greater extent for the rpoS deletion strain. Survival at pH 2 was increased in strains lacking the anaerobic regulator fnr. During anaerobic growth at pH 5.5, strains deleted for fnr showed enhanced transcription of acid-survival genes gadB, cfa, and hdeA, as well as catalase (katE. We show that E. coli cultured under oxygen exclusion (<6 µM O2 requires mechanisms different from those of aerated cultures. Extreme acid survival is more sensitive to autoclave products under oxygen exclusion.

  2. Comparative study on the effect of boiling, autoclaving and irradiation treatments of artichoke by-product on growth perfor mance and digestibility of broiler chicks

    International Nuclear Information System (INIS)

    Mekkawy, S.H.; Zakaria, S.M.; El-Faramawy, A.A.

    2003-01-01

    Sixty broiler chicks (21 days old) were assigned into six equal groups. artichoke by-product (ABP) was subjected to different treatments (Boiling, autoclaving and gamma irradiation at 75 and 100 kGy). The objective of the present study was to evaluate the effects of using ABP with different treatments on growth performance and their nutrient digestibility. Results revealed that, chicks fed diets containing raw ABP or irradiated with 100 kGy showed the highest values of live body weight, body weight gain, feed intake and dressing percentages compared with those fed a control diet. The lowest values of those parameters resulted by the chicks fed the diets of boiling or autoclaving ABP. Digestibility coefficients of crude protein, nitrogen free extract, crude fiber and organic matter increased by increased by increasing dose level of gamma irradiation. It could be recommended to use ABP in raw state up to 10% replacement of yellow corn without any adverse effects on chick performance. The use of irradiation treatment of ABP at 100 kGy improved remarkable feed utilization and growth performance

  3. Analysis of temperature dependence of {sup 35}Cl-NQR frequency in 2,4-D herbicide (2,4-dichlorophenoxy acetic acid); Analiza temperaturowej zaleznosci czestosci {sup 35}Cl-NQR w herbicydzie 2,4-D (kwas dichlorofenoksyoctowy)

    Energy Technology Data Exchange (ETDEWEB)

    Mazurek, P.; Ostafin, M.; Kasprzak, J.; Nogaj, B. [Inst. Fizyki, Uniwersytet A. Mickiewicza, Poznan (Poland)

    1994-12-31

    Biological activity of herbicide depends on electronic structure and molecule dynamics. The former parameter has been investigated by means of NQR spectra on {sup 35}Cl nuclei of 2,4-dichlorophenoxy acetic acid. The analysis of temperature dependency of observed frequency has been done. 12 refs, 3 figs, 1 tab.

  4. On the problem of safe usage of 12MKh steel at elevated temperatures and high hydrogen pressures

    International Nuclear Information System (INIS)

    Archakov, Yu.I.; Teslya, B.M.

    1982-01-01

    The behaviour of the 12MKh steel in hydrogen at pressures of 4-100 MPa and temperatures of 450-600 deg C has been investigated to study the regularities of hydrogen corrosion process. The samples are held in hydrogen under all-round compression in autoclaves with subsequent determination of mechanical properties, carbon content and microstructure. Dependencies of time to begining of intensive embrittlement under given conditions are found. The empiric equation for the calculation of time to beginning of hydrogen corrosion is derived, the safe usage of the 12MKh steel at different temperatures and pressures are determined

  5. Fusion neutron irradiation of Ni(Si) alloys at high temperature

    International Nuclear Information System (INIS)

    Huang, J.S.; Guinan, M.W.; Hahn, P.A.

    1987-09-01

    Two Ni-4% Si alloys, with different cold work levels, are irradiated with 14 MeV fusion neutrons at 623 K, and their Curie temperatures are monitored during irradiation. The results are compared to those of an identical alloy irradiated by 2 MeV electrons. The results show that increasing dislocation density increases the Curie temperature change rate. At the same damage rate, the Curie temperature change rate for the alloy irradiated by 14 MeV fusion neutrons is only 6 to 7% of that for an identical alloy irradiated by 2 MeV electrons. It is well known that the migration of radiation induced defects contributes to segregation of silicon atoms at sinks in this alloy, causing the Curie temperature changes. The current results imply that the relative free defect production efficiency decreases from one for the electron irradiated sample to 6 to 7% for the fusion neutron irradiated sample. 17 refs., 4 figs., 1 tab

  6. Fusion neutron irradiation of Ni(Si) alloys at high temperature

    Energy Technology Data Exchange (ETDEWEB)

    Huang, J.S.; Guinan, M.W.; Hahn, P.A.

    1987-09-01

    Two Ni-4% Si alloys, with different cold work levels, are irradiated with 14 MeV fusion neutrons at 623 K, and their Curie temperatures are monitored during irradiation. The results are compared to those of an identical alloy irradiated by 2 MeV electrons. The results show that increasing dislocation density increases the Curie temperature change rate. At the same damage rate, the Curie temperature change rate for the alloy irradiated by 14 MeV fusion neutrons is only 6 to 7% of that for an identical alloy irradiated by 2 MeV electrons. It is well known that the migration of radiation induced defects contributes to segregation of silicon atoms at sinks in this alloy, causing the Curie temperature changes. The current results imply that the relative free defect production efficiency decreases from one for the electron irradiated sample to 6 to 7% for the fusion neutron irradiated sample. 17 refs., 4 figs., 1 tab.

  7. Temperature-sensitive microemulsion gel: an effective topical delivery system for simultaneous delivery of vitamins C and E.

    Science.gov (United States)

    Rozman, Branka; Zvonar, Alenka; Falson, Francoise; Gasperlin, Mirjana

    2009-01-01

    Microemulsions (ME)--nanostructured systems composed of water, oil, and surfactants--have frequently been used in attempts to increase cutaneous drug delivery. The primary objective addressed in this work has been the development of temperature-sensitive microemulsion gel (called gel-like ME), as an effective and safe delivery system suitable for simultaneous topical application of a hydrophilic vitamin C and a lipophilic vitamin E. By changing water content of liquid o/w ME (o/w ME), a gel-like ME with temperature-sensitive rheological properties was formed. The temperature-driven changes in its microstructure were confirmed by rotational rheometry, viscosity measurements, and droplet size determination. The release studies have shown that the vitamins' release at skin temperature from gel-like ME were comparable to those from o/w ME and were much faster and more complete than from o/w ME conventionally thickened with polymer (o/w ME carbomer). According to effectiveness in skin delivery of both vitamins, o/w ME was found the most appropriate, followed by gel-like ME and by o/w ME carbomer, indicating that no simple correlation between vitamins release and skin absorption could be found. The cytotoxicity studies revealed good cell viability after exposure to ME and confirmed all tested microemulsions as nonirritant.

  8. Sorption and precipitation of Mn2+ by viable and autoclaved Shewanella putrefaciens: Effect of contact time

    KAUST Repository

    Chubar, Natalia

    2013-01-01

    The sorption of Mn(II) by viable and inactivated cells of Shewanella putrefaciens, a non-pathogenic, facultative anaerobic, gram-negative bacterium characterised as a Mn(IV) and Fe(III) reducer, was studied under aerobic conditions, as a function of pH, bacterial density and metal loading. During a short contact time (3-24h), the adsorptive behaviour of live and dead bacteria toward Mn(II) was sufficiently similar, an observation that was reflected in the studies on adsorption kinetics at various metal loadings, effects of pH, bacteria density, isotherms and drifting of pH during adsorption. Continuing the experiment for an additional 2-30days demonstrated that the Mn(II) sorption by suspensions of viable and autoclaved cells differed significantly from one another. The sorption to dead cells was characterised by a rapid equilibration and was described by an isotherm. In contrast, the sorption (uptake) to live bacteria exhibited a complex time-dependent uptake. This uptake began as adsorption and ion exchange processes followed by bioprecipitation, and it was accompanied by the formation of polymeric sugars (EPS) and the release of dissolved organic substances. FTIR, EXAFS/XANES and XPS demonstrated that manganese(II) phosphate was the main precipitate formed in 125ml batches, which is the first evidence of the ability of microbes to synthesise manganese phosphates. XPS and XANES spectra did not detect Mn(II) oxidation. Although the release of protein-like compounds by the viable bacteria increased in the presence of Mn2+ (and, by contrast, the release of carbohydrates did not change), electrochemical analyses did not indicate any aqueous complexation of Mn(II) by the organic ligands. © 2012 Elsevier Ltd.

  9. Search for diffusion of counter-passing MeV ions in the TFTR tokamak

    International Nuclear Information System (INIS)

    Zweben, S.J.; Boivin, R.; Chang, C.S.; Hammett, G.; Mynick, H.E.

    1991-07-01

    Confinement studies of MeV ions will play an important role in the research leading to burning plasmas in tokamaks, since any significant radial transport of MeV alpha particles will affect the heating rate or heating profiles of these plasmas. Because the energy, gyroradius, and collisionality of these MeV ions is very different from that of the background plasma, their transport rates cannot be assumed equal to those of the bulk plasma ions. Note that the desired confinement time for 3.5 MeV alphas is set by their thermalization time, which can be up to τ th,α ∼1 sec for the steady-state phase of ITER, requiring D 2 /sec. This is equivalent to over ∼100,000 alpha particle transits of the torus. 28 refs., 24 figs., 2 tabs

  10. Uranium recovery by leaching with sodium carbonate at high temperature and pressure

    International Nuclear Information System (INIS)

    Soerensen, E.; Koefoed, S.; Lundgaard, T.

    1990-09-01

    An alkaline rock from the Ilimaussaq instrusion, SW Greenland, was proposed as a source of uranium. Its principal uranium bearing mineral, Steenstrupine, is a complex sodium REE phosphosilicate in which Fe, Mn, Th and U are minor constituents. A special feature of this ore body is the content of water soluble minerals: NaF (Villiaumite), Na 2 Si 2 O 5 (Natrosilite) and an organic substance which displays the characteristics of humus. Sulfides are sparse, the most important one being ZnS (Sphalerite) of which the content is generally less than 0.5%. In the mineral under consideration (Lujavrite) the Steenstrupine is mainly finelay disseminated throughout the rock, yielding a uranium content of 300-400 ppm and thorium content of 800-1000 ppm. Laboratory tests indicated that high temperature carbonate leaching was necessary to decompose Steenstrupine. The optium temperature was shown to be 260 deg. C and the leach liquor composition 120 g/l of NaHCO 3 and 20 g/l of Na 2 C0 3 . Addition of oxygen is necessary. The process was developed to industrial scale in a continuous pipe autoclave with a retention time of 20 min. After filtering on a belt filter, the liquor was recycled several times to obtain a higher U-concentration. By reductive precipitation with iron powder a raw UO 2 was obtained. It was purified after dissolution in HNO 3 . An overall yield of 80% could be obtained. (author) 32 tabs., 13 ills., 24 refs

  11. Performance of iron–chromium–aluminum alloy surface coatings on Zircaloy 2 under high-temperature steam and normal BWR operating conditions

    Energy Technology Data Exchange (ETDEWEB)

    Zhong, Weicheng; Mouche, Peter A.; Han, Xiaochun [University of Illinois, Department of Nuclear, Radiological, and Plasma Engineering, Urbana, IL 61801 (United States); Heuser, Brent J., E-mail: bheuser@illinois.edu [University of Illinois, Department of Nuclear, Radiological, and Plasma Engineering, Urbana, IL 61801 (United States); Mandapaka, Kiran K.; Was, Gary S. [University of Michigan, Department of Nuclear Engineering and Radiological Sciences, Ann Arbor, MI 48109 (United States)

    2016-03-15

    Iron-chromium-aluminum (FeCrAl) coatings deposited on Zircaloy 2 (Zy2) and yttria-stabilized zirconia (YSZ) by magnetron sputtering have been tested with respect to oxidation weight gain in high-temperature steam. In addition, autoclave testing of FeCrAl-coated Zy2 coupons under pressure-temperature-dissolved oxygen coolant conditions representative of a boiling water reactor (BWR) environment has been performed. Four different FeCrAl compositions have been tested in 700 °C steam; compositions that promote alumina formation inhibited oxidation of the underlying Zy2. Parabolic growth kinetics of alumina on FeCrAl-coated Zy2 is quantified via elemental depth profiling. Autoclave testing under normal BWR operating conditions (288 °C, 9.5 MPa with normal water chemistry) up to 20 days demonstrates observable weight gain over uncoated Zy2 simultaneously exposed to the same environment. However, no FeCrAl film degradation was observed. The 900 °C eutectic in binary Fe–Zr is addressed with the FeCrAl-YSZ system. - Graphical abstract: Weight gain normalized to total sample surface area versus time during 700 °C steam exposure for FeCrAl samples with different composition (A) and Fe/Cr/Al:62/4/34 (B). In both cases, the responses of uncoated Zry2 (Zry2-13A and Zry2-19A) are shown for comparison. This uncoated Zry2 response shows the expected pre-transition quasi-cubic kinetic behavior and eventual breakaway (linear) kinetics. Highlights: • FeCrAl coatings deposited on Zy2 have been tested with respect to oxidation in high-temperature steam. • FeCrAl compositions promoting alumina formation inhibited oxidation of Zy2 and delay weight gain. • Autoclave testing to 20 days of coated Zy2 in a simulated BWR environment demonstrates minimal weight gain and no film degradation. • The 900 °C eutectic in binary Fe-Zr is addressed with the FeCrAl-YSZ system.

  12. Thermal Dark Matter Below a MeV.

    Science.gov (United States)

    Berlin, Asher; Blinov, Nikita

    2018-01-12

    We consider a class of models in which thermal dark matter is lighter than a MeV. If dark matter thermalizes with the standard model below the temperature of neutrino-photon decoupling, equilibration and freeze-out cool and heat the standard model bath comparably, alleviating constraints from measurements of the effective number of neutrino species. We demonstrate this mechanism in a model consisting of fermionic dark matter coupled to a light scalar mediator. Thermal dark matter can be as light as a few keV, while remaining compatible with existing cosmological and astrophysical observations. This framework motivates new experiments in the direct search for sub-MeV thermal dark matter and light force carriers.

  13. Environmental degradation in biocomposites

    CSIR Research Space (South Africa)

    John, Maya J

    2017-06-01

    Full Text Available green flax fibres and duralin flax fibres where flax fibres were subjected to steam or water-heating at temperatures above 160°C for 30 min in an autoclave. The fibres were placed in dessicators at different relative hu- midities followed by weighing...-epoxy composites containing fillers of cow dung, wheat husk, and rice husk. The authors immersed samples in water at 100°C for 24 h. Samples were also placed in water at room temperature for a week and the resulting changes in tensile properties were monitored...

  14. Fusion neutron irradiation of Ni-Si alloys at high temperature*1

    Science.gov (United States)

    Huang, J. S.; Guinan, M. W.; Hahn, P. A.

    1988-07-01

    Two Ni-4% Si alloys, with different cold work levels, have been irradiated with 14-MeV fusion neutrons at 623 K, and their Curie temperatures have been monitored during irradiation. The results are compared to those of an identical alloy irradiated by 2-MeV electrons. The results show that increasing dislocation density increases the Curie temperature change rate. At the same damage rate, the Curie temperature change rate for the alloy irradiated by 14-MeV fusion neutrons is only 6-7% of that for an identical alloy irradiated by 2-MeV electrons. It is well known that the migration of radiation induced defects contributes to segregation of silicon atoms at sinks in this alloy, causing the Curie temperature changes. The current results imply that the relative free defect production efficiency decreases from one for the electron irradiated sample to 6-7% for the fusion neutron irradiated sample.

  15. Solvent-free and room temperature synthesis of 3-arylquinolines from different anilines and styrene oxide in the presence of Al2O3/MeSO3H

    Directory of Open Access Journals (Sweden)

    Hashem Sharghi

    2017-09-01

    Full Text Available A highly efficient, simple and environmentally friendly synthesis of 3-arylquinolines has been developed in the presence of Al2O3/MeSO3H via one-pot reaction of anilines and styrene oxide. This methodology provides very rapid access to 3-arylquinolines in good to excellent yields under solvent-free conditions at room temperature in air.

  16. Preparation of Clinically Useful Sennoside-reduced Rhubarb.

    Science.gov (United States)

    Arai, Makoto; Nakada, Yoshinobu; Kajiwara, Kagemasa; Kimura, Minoru; Ishii, Naoaki

    2016-03-20

    The aim of this study was to develop a method of removing sennoside to reduce the cathartic effect of rhubarb while conserving its other pharmacological activities. Rhubarb powder was steam autoclaved at 121°C and 0.14 MPa for 20, 60, or 120 minutes, and HPLC analysis was conducted to determine levels of rhubarb components. Mice were fed non-autoclaved or 20-minute-autoclaved rhubarb extracts. Feces were collected and weighed over a 24-hour period. India ink was orally administered to determine the distance of fecal migration through the intestinal tract. Autoclaving 20, 60, and 120 minutes decreased sennoside A and B to trace levels but only autoclaving 20 minutes conserved most of the (+)-catechin, (-)-epicatechin, and (-)-epicatechin gallate contents (i.e., 69%, 90%, 88%, respectively). Therefore only rhubarb autoclaved for 20 minutes was used in subsequent experiments. Fecal output (in g) in mice treated with water (control), autoclaved rhubarb, and non-autoclaved rhubarb was 2.78 ± 0.07, 3.30 ± 0.13 (p = 0.348), and 3.81 ± 0.07 (p = 0.005). India ink migration was far less in mice treated with autoclaved rhubarb vs non-autoclaved rhubarb. Steam autoclaving the rhubarb for 20 minutes reduces sennoside levels and its cathartic activity while conserving its other pharmacological activities.

  17. Selfconsistent calculations at finite temperatures

    International Nuclear Information System (INIS)

    Brack, M.; Quentin, P.

    1975-01-01

    Calculations have been done for the spherical nuclei 40 Ca, 208 Pb and the hypothetical superheavy nucleus with Z=114, A=298, as well as for the deformed nucleus 168 Yb. The temperature T was varied from zero up to 5 MeV. For T>3 MeV, some numerical problems arise in connection with the optimization of the basis when calculating deformed nuclei. However, at these high temperatures the occupation numbers in the continuum are sufficiently large so that the nucleus starts evaporating particles and no equilibrium state can be described. Results are obtained for excitation energies and entropies. (Auth.)

  18. Interior Temperature Measurement Using Curved Mercury Capillary Sensor Based on X-ray Radiography

    Science.gov (United States)

    Chen, Shuyue; Jiang, Xing; Lu, Guirong

    2017-07-01

    A method was presented for measuring the interior temperature of objects using a curved mercury capillary sensor based on X-ray radiography. The sensor is composed of a mercury bubble, a capillary and a fixed support. X-ray digital radiography was employed to capture image of the mercury column in the capillary, and a temperature control system was designed for the sensor calibration. We adopted livewire algorithms and mathematical morphology to calculate the mercury length. A measurement model relating mercury length to temperature was established, and the measurement uncertainty associated with the mercury column length and the linear model fitted by least-square method were analyzed. To verify the system, the interior temperature measurement of an autoclave, which is totally closed, was taken from 29.53°C to 67.34°C. The experiment results show that the response of the system is approximately linear with an uncertainty of maximum 0.79°C. This technique provides a new approach to measure interior temperature of objects.

  19. Elastic scattering of 120, 145 and 172.5 MeV α-particles by 12C, 24Mg and 27Al and optical model analysis

    International Nuclear Information System (INIS)

    Wiktor, S.; Mayer-Boericke, C.; Kiss, A.; Rogge, M; Turek, P.

    1980-12-01

    The 120,145 and 172.5 MeV α-particle beams from JULIC were used to measure differential cross sections for elastic scattering on 12 C, 24 Mg and 27 Al in the angular range from about 5deg to 70deg (c.m. system). The angular distributions were analysed extensively in terms of the optical model using a variety of potential forms. Apart from the parametrized forms of potential, as Wood-Saxon (WS) or rather (WS)sup(ν) also a model independent representation of potential spline potential was employed. The analysis based on the parametrized forms of the potential made it possible to find the best fit parameter sets, which were than examined on their uniqueness and energy dependence. Emphasis was given to gaining information on the radial shape of the potential. (author)

  20. Study of two photon production process in proton-proton collisions at 216 MeV

    International Nuclear Information System (INIS)

    Khrykin, A.S.

    2002-01-01

    The energy spectrum for high energy γ-rays (Eγ ≥ 10 MeV) from the process pp → γγX emitted at 90 deg. in the laboratory frame has been measured at 216 MeV. The resulting photon energy spectrum extracted from γ - γ coincidence events consists of a narrow peak (5.3σ) at a photon energy of about 24 MeV and a relatively broad peak (3.5σ) in the energy range of (50 - 70) MeV. This behavior of the photon energy spectrum is interpreted as a signature of the exotic dibaryon resonance d 1 * with a mass of about 1956 MeV which is assumed to be formed in the radiative process pp → γd 1 * followed by its electromagnetic decay via the d 1 * → ppγ mode. The experimental spectrum is compared with those obtained by means of Monte Carlo simulations

  1. Efficient prepreg recycling at low temperatures

    Science.gov (United States)

    Pannkoke, Kord; Oethe, Marcus; Busse, Jürgen

    When manufacturing fibre reinforced plastics engineers are still confronted with a lack of experience concerning efficient recycling methods for prepreg cutting waste. Normally, the prepregs are cured and subsequently milled to use them as a filler material for polymers. However, this method is expensive and it is difficult to find applications for the milled FRP. An alternative method to recycle CFRP prepregs will be presented in this paper. Cutting the uncured prepreg waste was done by means of a saw mill which was cooled down to low temperatures. Working temperatures of -30°C are sufficient to harden the uncured resin and to achieve cuttable prepregs. Furthermore, post-curing during the cutting process is avoided with this technique. The result is a `cotton'-like matted structure with random fibre orientation and fibre length distribution. Subsequent curing was done by means of a press and an autoclave, respectively. It will be shown by means of tension and bending tests that low-temperature cutting of uncured prepregs is a way to partly conserve the high valuation of FRP during recycling. Furthermore, it offers possibilities for various applications.

  2. Confinement of 2,4 MeV deuterons by plasmoids and focalization of electron beams in plasma focus discharges

    International Nuclear Information System (INIS)

    Nardi, V.; Bostick, W.; Prior, W.; Feugeas, J.; Bortolotti, A.

    1982-01-01

    A detailed analysis has been completed on the internal structure of ions and electron beams which are efected, along the system axis, in opposite directions (0 0 and 180 0 ). An image (contact print) of plasmoids which emit MeV deuterons is formed by the deuteron emission and it is revealed by etching deuteron tracks in a target of plastic material (CR-39). Ion-imaging with different energy filters discriminates between tracks of plasmoid ions and tracks of charged products of D-D fusion reactions. Ions-imaging can also discriminate plasmoid deuterons from MeV deuterons of a directed beam. (L.C.) [pt

  3. STRUCTURAL SOLUTIONS AND SPECIAL FEATURES OF THE THERMAL PROTECTION ANALYSIS OF EXTERIOR WALLS OF BUILDINGS MADE OF AUTOCLAVED GAS-CONCRETE BLOCKS

    Directory of Open Access Journals (Sweden)

    Bedov Anatolij Ivanovich

    2012-10-01

    Full Text Available Relevant structural solutions, physical and mechanical characteristics, coefficients of thermal conductivity for exterior masonry walls made of autoclaved gas-concrete blocks are provided in the article. If a single-layer wall is under consideration, an autoclaved gas-concrete block is capable of performing the two principal functions of a shell structure, including the function of thermal protection and the bearing function. The functions are performed simultaneously. Therefore, the application of the above masonry material means the design development and erection of exterior walls of residential buildings noteworthy for their thermal efficiency. In the event of frameless structures, the height of the residential building in question may be up to 5 stories, while the use of a monolithic or a ready-made frame makes it possible to build high-rise buildings, and the number of stories is not limited in this case. If the average block density is equal to 400…500 kilograms per cubic meter, the designed wall thickness is to be equal to 400 mm. Its thermal resistance may be lower than the one set in the event of the per-element design of the thermal protection (Rreq = 3.41 м2 C/Watt, in Ufa, although it will meet the requirements of the applicable regulations if per-unit power consumption rate is considered.

  4. Incomplete deep inelastic processes in 100Mo + 100Mo and 120Sn + 120Sn at 18 and 24 MeV/u

    International Nuclear Information System (INIS)

    Petrovici, M.

    1989-12-01

    Experimental evidence on inclomplete deep inelastic process in 100 Mo + 100 Mo at 18.67 MeV/u, 23.75 MeV/u and in 120 Sn + 120 Sn at 18.34 MeV/u are presented. Such a mechanism is responsible for strong deviations observed at these incident energies in σ 2 Z -TKEL/l g (for two-body) and P 3 /(P 2 + P 3 )-TKEL (for three-body) systematics. Calculations which predict the number of preequilibrium emitted nucleons and the corresponding excitation energy per nucleon that remains in the dinuclear system could explain the observed discrepancies. (author)

  5. The effect of a change in sleep-wakefulness timing, bright light and physical exercise interventions on 24-hour patterns of performance, mood and body temperature.

    Science.gov (United States)

    Iskra-Golec, I; Fafrowicz, M; Marek, T; Costa, G; Folkard, S; Foret, J; Kundi, M; Smith, L

    2001-12-01

    Experiments consisting of baseline, bright light and physical exercise studies were carried out to compare the effect of a 9-hour delay in sleep-wakefulness timing, and the effects of bright light and physical exercise interventions on 24-hour patterns of performance, mood and body temperature were examined. Each study comprised a 24-hour constant routine at the beginning followed by 3 night shifts and 24-hour constant routine at the end. Performance on tasks differing in cognitive load, mood and body temperature was measured during each constant routine and the interventions were applied during the night shifts. The 24-hour pattern of alertness and performance on the tasks with low cognitive load in post-treatment conditions followed the change in sleep-wakefulness timing while more cognitively loaded tasks tended to show a reverse trend when compared to pre-treatment conditions. There was a phase delay around 4 hours in circadian rhythms of body temperature in post-treatment conditions.

  6. Comparing two enhancing methods for improving kitchen waste anaerobic digestion: bentonite addition and autoclaved de-oiling pretreatment

    DEFF Research Database (Denmark)

    Zhang, Duojiao; Duan, Na; Tian, Hailin

    2018-01-01

    The effects of different enhancement methods, including adding bentonite (1.25%, w/w, wet substrate) and autoclaved de-oiling pretreatment (121 °C, 30 minutes), on the anaerobic digestion of kitchen waste (KW) were comparably studied. Mesophilic continuous stirred tank reactors were used under...... different organic loading rates (OLRs) of 1.11 to 1.84 gVS (volatile solid)L−1d−1 and two different hydraulic retention times (HRTs) (20 d and 25 d). In this study, two enhancement methods and extending HRT could prevent volatile fatty acids (VFA) accumulation and obtain a high methane production at low OLR...... design and process evaluation of a CSTR biogas plant treating with KW based on the laboratory experiment was stated....

  7. Operating Cell Temperature Determination in Flat-Plate Photovoltaic Modules

    International Nuclear Information System (INIS)

    Chenlo, F.

    2002-01-01

    Two procedures (simplified and complete) to determine me operating cell temperature in photovoltaic modules operating in real conditions assuming isothermal stationary modules are presented in this work. Some examples are included that show me dependence of this temperature on several environmental (sky, ground and ambient temperatures, solar irradiance, wind speed, etc.) and structural (module geometry and size, encapsulating materials, anti reflexive optical coatings, etc.) factors and also on electrical module performance. In a further step temperature profiles for non-isothermal modules are analysed besides transitory effects due to variable irradiance and wind gusts. (Author) 27 refs

  8. The pion quasiparticle in the low-temperature phase of QCD

    Directory of Open Access Journals (Sweden)

    Brandt Bastian B.

    2018-01-01

    Full Text Available We extend our previous studies [PhysRevD.90.054509, PhysRevD.92.094510] of the pion quasiparticle in the low-temperature phase of two-flavor QCD with support from chiral effective theory. This includes the analysis performed on a finite temperature ensemble of size 20 × 643 at T ≈ 151MeV and a lighter zero-temperature pion mass mπ ≈ 185 MeV. Furthermore, we investigate the Gell-Mann–Oakes-Renner relation at finite temperature and the Dey-Eletsky-Ioffe mixing theorem at finite quark mass.

  9. solveME: fast and reliable solution of nonlinear ME models

    DEFF Research Database (Denmark)

    Yang, Laurence; Ma, Ding; Ebrahim, Ali

    2016-01-01

    Background: Genome-scale models of metabolism and macromolecular expression (ME) significantly expand the scope and predictive capabilities of constraint-based modeling. ME models present considerable computational challenges: they are much (>30 times) larger than corresponding metabolic reconstr......Background: Genome-scale models of metabolism and macromolecular expression (ME) significantly expand the scope and predictive capabilities of constraint-based modeling. ME models present considerable computational challenges: they are much (>30 times) larger than corresponding metabolic...... reconstructions (M models), are multiscale, and growth maximization is a nonlinear programming (NLP) problem, mainly due to macromolecule dilution constraints. Results: Here, we address these computational challenges. We develop a fast and numerically reliable solution method for growth maximization in ME models...

  10. Effect of morning bright light on body temperature, plasma cortisol and wrist motility measured during 24 hour of constant conditions.

    Science.gov (United States)

    Foret, J; Aguirre, A; Touitou, Y; Clodoré, M; Benoit, O

    1993-06-11

    Using 24 h constant conditions, time course of body temperature, plasma cortisol and wrist motility was measured in response to a 3 day morning 2 h bright light pulse. This protocol demonstrated that a 2000 lux illumination was sufficient to elicit a shift of about 2 h of temperature minimum and cortisol peak. In reference session, actimetric recordings showed a circadian time course, closely in relation with core temperature. Bright light pulse resulted in a decrease of amplitude and a disappearance of circadian pattern of actimetry.

  11. Histologic responses in sixty multibacillary leprosy patients inoculated with autoclaved Mycobacterium leprae and live BCG.

    Science.gov (United States)

    Meyers, W M; McDougall, A C; Fleury, R N; Neves, R; Reyes, O; Binford, C H

    1988-06-01

    Sixty lepromatous or borderline lepromatous patients were submitted to immunotherapy with a mixture of autoclaved Mycobacterium leprae and BCG. The histopathologic findings in skin biopsy specimens taken before and after immunotherapy were evaluated independently by six histopathologists in a workshop setting. Their pooled observations on diagnosis and classification were analyzed to assess the histopathologic changes following various periods of immunotherapy. Expressing the results as the average value of five to six independent observations, there were changes in classification of reversal or upgrading toward the tuberculoid end of the leprosy spectrum in 90.5% of the patients initially classified as lepromatous (LL), and in 83.3% of those initially classified as borderline lepromatous (BL). The histopathologic findings amply support the clinical, bacteriologic and immunological changes following immunotherapy from LL or BL, to BL, mid-borderline (BB) or even borderline tuberculoid (BT) leprosy.

  12. Mechanism of Corrosion by Naphthenic Acids and Organosulfur Compounds at High Temperatures

    Science.gov (United States)

    Jin, Peng

    Due to the law of supply and demand, the last decade has witnessed a skyrocketing in the price of light sweet crude oil. Therefore, refineries are increasingly interested in "opportunity crudes", characterized by their discounted price and relative ease of procurement. However, the attractive economics of opportunity crudes come with the disadvantage of high acid/organosulfur compound content, which could lead to corrosion and even failure of facilities in refineries. However, it is generally accepted that organosulfur compounds may form protective iron sulfide layers on the metal surface and decrease the corrosion rate. Therefore, it is necessary to investigate the corrosive property of crudes at high temperatures, the mechanism of corrosion by acids (naphthenic acids) in the presence of organosulfur compounds, and methods to mitigate its corrosive effect. In 2004, an industrial project was initiated at the Institute for Corrosion and Multiphase Technology to investigate the corrosion by naphthenic acids and organosulfur compounds. In this project, for each experiment there were two experimentation phases: pretreatment and challenge. In the first pretreatment phase, a stirred autoclave was filled with a real crude oil fraction or model oil of different acidity and organosulfur compound concentration. Then, the stirred autoclave was heated to high temperatures to examine the corrosivity of the oil to different materials (specimens made from CS and 5% Cr containing steel were used). During the pretreatment, corrosion product layers were formed on the metal surface. In the second challenge phase, the steel specimens pretreated in the first phase were inserted into a rotating cylinder autoclave, called High Velocity Rig (HVR). The HVR was fed with a high-temperature oil solution of naphthenic acids to attack the iron sulfide layers. Based on the difference of specimen weight loss between the two steps, the net corrosion rate could be calculated and the protectiveness

  13. Seasonal variation in the effect of constant ambient temperature of 24 C in reducing FDG uptake by brown adipose tissue in children

    International Nuclear Information System (INIS)

    Zukotynski, Katherine A.; Fahey, Frederic H.; Laffin, Stephen; Davis, Royal; Treves, S. Ted; Grant, Frederick D.; Drubach, Laura A.

    2010-01-01

    It has been shown that warming patients prior to and during 18 F-FDG uptake by controlling the room temperature can decrease uptake by brown adipose tissue (BAT). The aim of this study is to determine if this effect is subject to seasonal variation. A retrospective review was conducted of all patients referred for whole-body 18 F-FDG PET between December 2006 and December 2008. After December 2007, all patients were kept in the PET injection room at a constant 24 C for 30 min before and until 1 h following FDG administration. Patients over 22 years of age and those who received pre-medication known to reduce FDG uptake by BAT were excluded. One hundred and three patients were warmed to 24 C prior to scanning. The number of patients showing uptake by BAT in this group was compared to a control group of 99 patients who underwent PET prior to December 2007 when the injection room temperature was 21 C. Uptake by BAT occurred in 9% of studies performed after patient warming (24 C), compared to 27% of studies performed on the control group (21 C) (p 0.05). Maintaining room temperature at a constant 24 C for 30 min prior to and 1 h after IV tracer administration significantly decreases FDG uptake by BAT in children. This effect is greatest in the summer and winter. (orig.)

  14. Synthesis of MIL-100(Fe at Low Temperature and Atmospheric Pressure

    Directory of Open Access Journals (Sweden)

    Jing Shi

    2013-01-01

    Full Text Available MIL-100(Fe, a mesoporous metal-organic framework (MOF, has a large BET specific surface area and pore volume with the presence of a significant amount of accessible Lewis acid metal sites upon dehydration. The structural characteristics of MIL-100(Fe make it a good candidate for potential applications in gas storage, separation, and heterogeneous catalysis. Mainly, this MOF is obtained by the hydrothermal synthesis in a Teflon-lined autoclave at high temperature (>150°C under static conditions. However, this method has several disadvantages such as high temperature, high (autogenous pressure, long time, and comparable low MOF yield. Therefore, development of a facile method for synthesis of MIL-100(Fe is vitally important for fundamental understanding and practical application. Herein, MIL-100(Fe is synthesized by a facile low-temperature (90% still could be achieved, suggesting that this simple and energy saving method has the potential to be used practically.

  15. The steam pressure effect on high temperature corrosion of zircaloy-4

    International Nuclear Information System (INIS)

    Kim, K. P.; Park, G. H.

    1998-01-01

    To find the effect of pressure on the high temperature oxidation of zircaloy-4, an autoclave capable of measuring the degree of oxidation at high temperatures and high pressure was manufactured. The degree of high temperature oxidation of zircaloy-4 was measured at three different conditions, high pressure steam, high pressure Ar gas with small amount of steam, and 1 atm steam. All the measurements were done at 750 deg C. The oxide thickness is much thicker in high pressure steam, comparing to that in the 1 atm steam. And, the higher is the steam pressure, the thicker becomes the oxide. No effect was observed in the case of high pressure Ar containing small amount of steam. Many cracks exist on the surface of specimens oxidized at high pressure steam, which come from the enhanced tetragonal to monoclinic phase transformation due to high pressure steam. The enhanced oxidation seems to oxide cracking

  16. T-x projections of phase diagrams of the MeF-BeF2 systems

    International Nuclear Information System (INIS)

    Korenev, Yu.M.; Rykov, A.N.; Novoselova, A.V.

    1976-01-01

    The T-x projections of the state diagrams of the systems MeF-BeF 2 (Me=Li-Rb) have been plotted. Transformation of P-x cross sections of the system state diagrams with decreasing temperature have been considered with the aid, of the general view of T-x projections. The nature of sublimation of the compounds formed in these systems is discussed

  17. Sterically Bulky NHC Adducts of GaMe3 and InMe3 for H2 Activation and Lactide Polymerization

    Directory of Open Access Journals (Sweden)

    Anaëlle Bolley

    2018-01-01

    Full Text Available The sterically bulky Ga(III and In(III (IPr*MMe3 adducts (1 and 2 and (SItBuMMe3 adducts (3 and 4 (M = Ga, In; IPr* = 1,3-bis{2,6-bis(diphenylmethyl-4-methylphenyl}-1,3-dihydro- imidazol-2-ylidene; SItBu = 1,3-bis(1,1-dimethylethyl-imidazolidin-2-ylidene were prepared and structurally characterized, allowing an estimation of the steric hindrance of such Lewis pairs (yields in 1–4: 92%, 90%, 73%, and 42%, respectively. While the IPr* adducts 1 and 2 are robust species, the more severely congested SItBu adducts 3 and 4 are more reactive and exhibit a limited stability in solution. Adduct (SItBuGaMe3 (3 reacts quickly with H2 at room temperature to afford the corresponding aminal product, 1,3-di-tert-butylimidazolidine (5, along with free GaMe3. Such Frustrated Lewis Pair (FLP reactivity constitutes the first instance of a H2 activation involving a simple trialkyl GaR3 species. Adduct 3 also mediates the ring-opening polymerization (ROP of rac-lactide at room temperature to afford cyclic polylactide (PLA.

  18. Temperature dependence of the electronic structure of Sr14Cu24O41 studied by resonant inelastic X-ray scattering

    International Nuclear Information System (INIS)

    Yoshida, M.; Ishii, K.; Ikeuchi, K.; Jarrige, I.; Murakami, Y.; Mizuki, J.; Tsutsui, K.; Tohyama, T.; Maekawa, S.; Kudo, K.; Koike, Y.; Endoh, Y.

    2010-01-01

    We report a resonant inelastic X-ray scattering (RIXS) study of charge excitations in the two-leg ladder Sr 14 Cu 24 O 41 . RIXS spectra at 1-5 eV are found to be dependent on temperature. An intraband excitation of the ladder, which appears as a continuum intensity below the Mott gap, decreases in intensity with temperature. Because the intraband excitation is related to the dynamics of doped holes in the ladder, its decrease of the intraband excitation is attributed to the reduction of the mobile holes in the ladder at low temperature.

  19. Pro Java ME Apps

    CERN Document Server

    Iliescu, Ovidiu

    2011-01-01

    Pro Java ME Apps gives you, the developer, the know-how required for writing sophisticated Java ME applications and for taking advantage of this huge potential market. Java ME is the largest mobile software platform in the world, supported by over 80% of all phones. You'll cover what Java ME is and how it compares to other mobile software platforms, how to properly design and structure Java ME applications, how to think like an experienced Java ME developer, what common problems and pitfalls you may run into, how to optimize your code, and many other key topics. Unlike other Java ME books out

  20. Extraction of low-temperature tar by various alcohols

    Energy Technology Data Exchange (ETDEWEB)

    Hara, N; Osawa, M; Azuma, H

    1948-01-01

    MeOH was the most effective of the alcohols tested (MeOH to pentanol) in extracting acid components from low-temperature tar. The optimum concentrations of MeOH were 70 to 80% for 1 extraction and 70 to 75% for repeated or continuous extractions when the solvent-tar ratio was 1:1. By 2 to 3 extractions neutral oil could be separated in about 90% yield including > 3% acidic oil.

  1. Characterization of 2 MeV, 4 MeV, 6 MeV and 18 MeV buildup caps for use with a 0.6 cubic centimeter thimble ionization chamber

    International Nuclear Information System (INIS)

    Salyer, R.L.; VanDenburg, J.W.; Prinja, A.K.; Kirby, T.; Busch, R.; Hong-Nian Jow

    1996-07-01

    The purpose of this research is to characterize existing 2 MeV, 4 MeV and 6 MeV buildup caps, and to determine if a buildup cap can be made for the 0.6 cm 3 thimble ionization chamber that will accurately measure exposures in a high-energy photon radiation field. Two different radiation transport codes were used to computationally characterize existing 2 MeV, 4 MeV, and 6 MeV buildup caps for a 0.6 cm 3 active volume thimble ionization chamber: ITS, The Integrated TIGER Series of Coupled Electron-Photon Monte Carlo Transport Codes; and CEPXS/ONEDANT, A One-Dimensional Coupled Electron-Photon Discrete Ordinates Code Package. These codes were also used to determine the design characteristics of a buildup cap for use in the 18 MeV photon beam produced by the 14 TW pulsed power HERMES-III electron accelerator. The maximum range of the secondary electron, the depth at which maximum dose occurs, and the point where dose and collision kerma are equal have been determined to establish the validity of electronic equilibrium. The ionization chamber with the appropriate buildup cap was then subjected to a 4 MeV and a 6 MeV bremmstrahlung radiation spectrum to determine the detector response

  2. Charged particle calorimetry of 40Ar + 27Al reactions from 36 to 65 MeV/u

    International Nuclear Information System (INIS)

    Cussol, D.; Bizard, G.; Brou, R.; Durand, D.; Louvel, M.; Patry, J.P.; Peter, J.; Sullivan, J.P.; Regimbart, R.; Steckmeyer, J.C.; Tamain, B.; Crema, E.; Cassagnou, Y.; Legrain, R.; Jeong, S.C.; Lee, S.M.; Nagashima, Y.; Nakagawa, T.; Ogihara, M.

    1992-04-01

    Temperatures and excitation energies have been independently measured for hot nuclei formed in the Ar on Al reactions from 36 to 65 MeV/u. Charged products have been measured in a geometry close to 4 π in the center of mass with multidetectors MUR and TONNEAU. The events have been sorted as a function of the impact parameter value. The products emitted from the equilibrated incomplete fusion nuclei are separated from the nucleons and clusters emitted in the first step of the collision (pre-equilibrium) and from the target-like nuclei. The qualitative variation of temperature and excitation energy values have been deduced from the charge distribution of residual nuclei and the transverse energy. Quantitative values are obtained from the kinetic energy distributions of particles in the frame of the reconstructed equilibrated nucleus. At each incident energy, the temperature and excitation energy are both increasing when the impact parameter value decreases. For central collisions (b<2fm), the temperature increases with the incident energy, slowly above 45 MeV/u, and reaches a value of 7 MeV. The excitation energy per nucleon increases similarly. The correlation between the excitation energy per nucleon and the temperature shows an evolution of the level density parameter value

  3. Evolution of giant dipole resonance width at low temperatures ...

    Indian Academy of Sciences (India)

    techniques. Several experiments have been performed by bombarding 7–12 MeV/nucleon alpha beam on various targets (63Cu, 115In and 197Au) and new datasets ... appears to be constant at its ground state value until a critical temperature is reached and subse- ..... it was 38.6 MeV for 63Cu at 35 MeV incident energy.

  4. Spin-flip (p,n) reactions on 26Mg, 54Fe, and 56Fe at selected proton bombarding energies in the range of 17 to 25 MeV

    International Nuclear Information System (INIS)

    Aron, D.L.

    1985-06-01

    New data are presented for the 26 Mg(p,n) 26 Al reaction at E/sub p/ = 19.12 and 24.97 MeV, for the 54 Fe(p,n) 54 Co reaction at E/sub p/ = 17.20, 18.60, and 24.60 MeV, and for the 56 Fe(p,n) 56 Co reaction at E/sub p/ = 19.12 and 24.59 MeV. Data were taken with the LLNL Cyclograaff at 16 angles from 3.5 0 to 159.0 0 . A large detector at 23.8 0 with a long neutron flight path collected high resolution spectra. This large detector also collected separate 0 0 high resolution data on the 26 Mg and 56 Fe(p,n) reactions at E/sub p/ = 19 MeV. Absolute differential (p,n) cross sections were extracted for 1 + states in 26 Al, 54 Co, and 56 Co, for the 0 + isobaric analong state (IAS) in 54 Co and 56 Co, for a 2 + state in each residual nucleus, and for the 0.199 MeV 7 + state of 54 Co. No new experimental states were identified. Only relative cross sections were extracted at 0 0 . Experimental angle-integrated cross sections were obtained for all but one state. DWBA79 was used, with the G-matrix effective nucleon-nucleon interaction of Bertsch et al. (with the central triplet-odd component V/sub to/ = O) and the Livermore shell model wave functions to calculate differential (p,n) cross sections to 1 + states and to the 54 Co and 56 Co IAS. Normalization of the DWBA angle-integrated cross sections to measurements for the 54 Co and 56 Co IAS (at E/sub p/ = 24.6 MeV) yielded the renormalized V/sub tau/ = 21.4 +- 2.1 MeV. Normalization of the DWBA angle-integrated cross sections to measurements for the 24.6 MeV 54 Co and 56 Co 1 + states, coupled with the normalization of the wave functions to previously experimentally determined GT strength, yield the renormalized V/sub sigmatau/ = 12.3 +- 1.2 MeV. The experimental Gamow-Teller strength B(GT)/sub exp./ of the T = 1 26 Al state at 9.44 MeV was found to be 0.69; B(GT)/sub exp/ of the T = 1 26 Al state at 10.47 MeV was found to be 0.39

  5. Volumetric Heat Generation and Consequence Raise in Temperature Due to Absorption of Neutrons from Thermal up to 14.9 MeV Energies

    CERN Document Server

    Massoud, E

    2003-01-01

    In this work, the heat generation rate and the consequence rise in temperature due to absorption of all neutrons from thermal energies (E<0.025) up to 14.9 MeV in water, paraffin wax, ordinary concrete and heavy concrete and heavy concrete as some selected hydrogenous materials are investigated. The neutron flux distributions are calculated by both ANISN-code and three group method in which the fast neutrons are expressed by the removal cross section concept while the other two groups (epithermal and thermal) are treated by the diffusion equation. The heat generation can be calculated from the neutron macroscopic absorption of each material or mixture multiplied by the corresponding neutron fluxes. The rise in temperature is then calculated by using both of the heat generation and the thermal conductivity of the selected materials. Some results are compared with the available experimental and theoretical data and a good agreement is achieved.

  6. Neutron ion temperature measurement

    International Nuclear Information System (INIS)

    Strachan, J.D.; Hendel, H.W.; Lovberg, J.; Nieschmidt, E.B.

    1986-11-01

    One important use of fusion product diagnostics is in the determination of the deuterium ion temperature from the magnitude of the 2.5 MeV d(d,n) 3 He neutron emission. The detectors, calibration methods, and limitations of this technique are reviewed here with emphasis on procedures used at PPPL. In most tokamaks, the ion temperature deduced from neutrons is in reasonable agreement with the ion temperature deduced by other techniques

  7. The gas bubbles distribution in 600 MeV protons irradiated aluminium

    International Nuclear Information System (INIS)

    Gavillet, D.; Martin, J.L.; Victoria, M.; Green, W.

    1984-01-01

    In order to simulate the damage produced by 14 MeV fusion neutrons, thin foils of high purity Al have been irradiated by a proton beam of 580 MeV (120μA). After irradiation at temperatures higher than 0.5 Tm transmission electron microscope observations of gas bubbles distribution were performed. At 200 0 C a uniform distribution of bubbles has been observed inside the grain. The average distance between bubbles and their density have been determined. The gas pressure inside the bubbles has been estimated [fr

  8. Some metallic materials and fluoride salts for high temperature applications

    International Nuclear Information System (INIS)

    Hosnedl, P.; Hron, M.; Matal, O.

    2009-01-01

    There has been a special Ni base alloy MONICR for high temperature applications in fluoride salt environments developed in the framework of the complex R and D program for the Molten Salt Reactor (MSR) - SPHINX (SPent Hot fuel Incinerator by Neutron fluX) concept development in the Czech Republic. Selected results of MONICR alloy tests and results of semi products fabrication from this alloy are discussed in the paper. The results of the structural materials tests are applied on semi-products and for the design of the testing devices as the autoclave in loop arrangement for high temperature fluoride salts applications. Material properties other Ni base alloys are compared to those of MONICR. Corrosion test results of the alloy A686 in the LiF - NaF - ZrF 4 molten salt are provided and compared to the measured values of the polarizing resistance. (author)

  9. WATER TEMPERATURE and other data from GERDA and CALANUS from 1972-03-14 to 1972-03-24 (NCEI Accession 9500067)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The data in this accession were collected from ships CALANUS and GERDA between March 14, 1972 and March 24, 1972. The real time data of water temperature at varying...

  10. Manufacturing And High Temperature Oxidation Properties Of Electro-Sprayed Fe-24.5% Cr-5%Al Powder Porous Metal

    Directory of Open Access Journals (Sweden)

    Lee Kee-Ahn

    2015-06-01

    Full Text Available Fe-Cr-Al based Powder porous metals were manufactured using a new electro-spray process, and the microstructures and high-temperature oxidation properties were examined. The porous materials were obtained at different sintering temperatures (1350°C, 1400°C, 1450°C, and 1500°C and with different pore sizes (500 μm, 450 μm, and 200 μm. High-temperature oxidation experiments (TGA, Thermal Gravimetry Analysis were conducted for 24 hours at 1000°C in a 79% N2+ 21% O2, 100 mL/min. atmosphere. The Fe-Cr-Al powder porous metals manufactured through the electro-spray process showed more-excellent oxidation resistance as sintering temperature and pore size increased. In addition, the fact that the densities and surface areas of the abovementioned powder porous metals had the largest effects on the metal’s oxidation properties could be identified.

  11. Shape evolution of 72,74Kr with temperature in covariant density functional theory

    Institute of Scientific and Technical Information of China (English)

    Wei Zhang; Yi-Fei Niu

    2017-01-01

    The rich phenomena of deformations in neutron-deficient krypton isotopes,such as shape evolution with neutron number and shape coexistence,have attracted the interest of nuclear physicists for decades.It is interesting to study such shape phenomena using a novel way,e.g.by thermally exciting the nucleus.In this work,we develop the finite temperature covariant density functional theory for axially deformed nuclei with the treatment of pairing correlations by the BCS approach,and apply this approach for the study of shape evolution in 72,74Kr with increasing temperature.For 72Kr,with temperature increasing,the nucleus firstly experiences a relatively quick weakening in oblate deformation at temperature T~0.9 MeV,and then changes from oblate to spherical at T~2.1 MeV.For 74Kr,its global minimum is at quadrupole deformationβ2 ~-0.14 and abruptly changes to spherical at T~ 1.7 MeV.The proton pairing transition occurs at critical temperature 0.6 MeV following the rule Tc=0.6Ap(0),where △p(0) is the proton pairing gap at zero temperature.The signatures of the above pairing transition and shape changes can be found in the specific heat curve.The single-particle level evolutions with temperature are presented.

  12. Temperature dependent energy levels of methylammonium lead iodide perovskite

    Science.gov (United States)

    Foley, Benjamin J.; Marlowe, Daniel L.; Sun, Keye; Saidi, Wissam A.; Scudiero, Louis; Gupta, Mool C.; Choi, Joshua J.

    2015-06-01

    Temperature dependent energy levels of methylammonium lead iodide are investigated using a combination of ultraviolet photoemission spectroscopy and optical spectroscopy. Our results show that the valence band maximum and conduction band minimum shift down in energy by 110 meV and 77 meV as temperature increases from 28 °C to 85 °C. Density functional theory calculations using slab structures show that the decreased orbital splitting due to thermal expansion is a major contribution to the experimentally observed shift in energy levels. Our results have implications for solar cell performance under operating conditions with continued sunlight exposure and increased temperature.

  13. Corrosion of Zircaloy-clad fuel rods in high-temperature PWRs: Measurement of waterside corrosion in North Anna Unit 1

    International Nuclear Information System (INIS)

    Balfour, M.G.; Kilp, G.R.; Comstock, R.J.; McAtee, K.R.; Thornburg, D.R.

    1992-03-01

    Twenty-four peripheral rods and two interior rods from North Anna Unit 1, End-of-Cycle 7, were measured at poolside for waterside corrosion on four-cycle Region 6 assemblies F35 and F66, with rod average burnups of 60 GWD/MTU. Similar measurements were obtained on 24 two-cycle fuel rods from Region 8A assemblies H02 and H10 with average burnups of about 40 GWD/MTU. The Region 6 peripheral rods had been corrosion measured previously after three cycles, at 45 GWD/MTU average burnup. The four-cycle Region 6 fuel rods showed high corrosion, compared to only intermediate corrosion level after three cycles. The accelerated corrosion rate in the fourth cycle was accompanied by extensive laminar cracking and spalling of the oxide film in the thickest regions. The peak corrosion of the two-cycle region 8A rods was 32 μm to 53 μm, with some isolated incipient oxide spalling. In conjunction with the in-reactor corrosion measurements, extensive characterization tests plus long-term autoclave corrosion tests were performed on archive samples of the three major tubing lots represented in the North Anna measurements. The autoclave tests generally showed the same ordering of corrosion by tubing lot as in the reactor; the chief difference between the archive tubing samples was a lower tin content (1.38 percent) for the lot with the lowest corrosion rate compared with a higher tin content (1.58) for the lot with the highest corrosion rate. There was no indication in the autoclave tests of an accelerated rate of corrosion as observed in the reactor

  14. Oxidation Behavior of Carbon Steel: Effect of Formation Temperature and pH of the Environment

    Science.gov (United States)

    Dubey, Vivekanand; Kain, Vivekanand

    2017-11-01

    The nature of surface oxide formed on carbon steel piping used in nuclear power plants affects flow-accelerated corrosion. In this investigation, carbon steel specimens were oxidized in an autoclave using demineralized water at various temperatures (150-300 °C) and at pH levels (neutral, 9.5). At low temperatures ( 240 °C) as confirmed by scanning electron microscopy. Electrochemical impedance measurement followed by Mott-Schottky analysis indicated an increase in defect density with exposure duration at 150 °C at neutral pH but a low and stable defect density in alkaline environment. The defect density of the oxide formed at neutral pH at 150-300 °C was always higher than that formed in alkaline environment as reported in the literature.

  15. Long-time aging in 3 mol.% yttria-stabilized tetragonal zirconia polycrystals at human body temperature.

    Science.gov (United States)

    Keuper, Melanie; Berthold, Christoph; Nickel, Klaus Georg

    2014-02-01

    We present new findings on the low-temperature degradation of yttria-stabilized zirconia at 37°C over several years and at high and low partial pressures of water. With the aid of focused ion beam cross-section confirmation studies we are able to show an extensive linear, continuous degradation without retardation, even at low temperatures and low water pressures. The characteristic layer growth and its inferred rate constant imply a lifetime of tens of years under simple tension and open the possibility of studying the longevity of these ceramics more rigorously. In addition, we show reproducibility complications of accelerated aging tests by the use of different autoclaves and possible implications for standardized procedures. Copyright © 2013 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  16. Electrochemical characterization of oxide film formed at high temperature on Alloy 690

    Energy Technology Data Exchange (ETDEWEB)

    Abraham, Geogy J., E-mail: gja@barc.gov.in [Materials Science Division, BARC, Mumbai 400 085 (India); Bhambroo, Rajan [Deptt. of Metallurgical Engg. and Mat. Sci., IIT Bombay, Mumbai 400 076 (India); Kain, V. [Materials Science Division, BARC, Mumbai 400 085 (India); Shekhar, R. [CCCM, BARC, Hyderabad 500 062 (India); Dey, G.K. [Materials Science Division, BARC, Mumbai 400 085 (India); Raja, V.S. [Deptt. of Metallurgical Engg. and Mat. Sci., IIT Bombay, Mumbai 400 076 (India)

    2012-02-15

    Highlights: Black-Right-Pointing-Pointer GD-QMS studies of high temperature oxide film formed on Alloy 690. Black-Right-Pointing-Pointer Defect density reduced with increase in temperature. Black-Right-Pointing-Pointer Electrochemical behaviour of oxide film correlated to the Cr-content in oxide. - Abstract: High temperature passivation studies on Alloy 690 were carried out in lithiated water at 250 Degree-Sign C, 275 Degree-Sign C and 300 Degree-Sign C for 72 h. The passive films were characterized by glow discharge-quadrupole mass spectroscopy (GD-QMS) for compositional variation across the depth and micro laser Raman spectroscopy for oxide composition on the surface. The defect density in the oxide films was established from the Mott-Schottky analysis using electrochemical impedance spectroscopy. Electrochemical experiments at room temperature in chloride medium revealed best passivity behaviour by the oxide film formed at 300 Degree-Sign C for 72 h. The electrochemical studies were correlated to the chromium (and oxygen) content of the oxide films. Autoclaving at 300 Degree-Sign C resulted in the best passive film formation on Alloy 690 in lithiated water.

  17. Temperature profile data from XBT casts from a World-Wide Distribution 31 March 1985 to 24 November 1990 (NODC Accession 9700191)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Physical data were collected from XBT casts from from a World-Wide Distribution from 31 March 1985 to 24 November 1990. Physical parameters include temperature...

  18. α-Tocopherol-5-Me-T. Synthesis, purification and characterization

    International Nuclear Information System (INIS)

    Corol-Cucu, Delia-Irina; Chiper, Diana; Mihaila, V.; Negoita, N.

    2000-01-01

    The E vitamine is named 'vitamine of antisterility' because it is essential for good functioning of genital organs. It is involved in cellular oxidation processes, in muscle creatinine metabolism and metabolism of saccharides encouraging glycogen deposition in tissues. The name of E vitamine is given to eight different compounds which have a ring with methyl and hydroxyl groups. Four of them, named tocopherols, contain a lateral saturated chain which derives from fitol and the others, named tocotrienols, have three double bonds in the lateral chain.This paper refers to synthesis, purification and characterization of α-tocopherol labelled with tritium in 5-methyl position. Tritium is different by the other hydrogen isotopes because it is the only radioactive isotope of hydrogen. The α-tocopherol-5-Me-T. The dry HCl is bubbled in a mixture of γ-tocopherol, paraformaldehyde and ZnCl 2 powder in dry Et 2 O. This solution remains at a standstill for a few hours and after that water is slowly added under stirring at low temperature ( 2 SO 4 . The next step is filtration and evaporation of ether stratum under nitrogen environment. One obtains 5-Cl-Me-α-tocopherol. For synthesis of α-tocopherol-5-Me-T the replacement of chlorine with tritium is done through catalytic dechlorination with Pd/C or Pd/CaCO 3 (10% Pd) as catalysts. One half of 5-Me-Cl compound is solved in dioxane and then the catalyst and deuterium are added under stirring, for 2 hours at room temperature. After filtration and washing with MeOH, the solvent is eliminated under vacuum conditions. Thus one obtains α-tocopherol-5-Me-T. The purification has been carried out through thin layer chromatography with C 6 H 6 as solvent (Al 2 O 3 as support) or solvent system C 6 H 6 : CH 3 OH (98:2, v/v) (silicagel as support). The determination of activity is carried out with LSC (Liquid Scintillation Counter). A 98% purity was determined through TLC in the same conditions while determination of activity

  19. Temperature-dependent optical potential and mean free path based on Skyrme interactions

    International Nuclear Information System (INIS)

    Ge Lingxiao; Zhuo Yizhong; Noerenberg, W.; Technische Hochschule Darmstadt

    1986-03-01

    Optical potentials and mean free paths of nucleons at finite temperatures are studied by utilizing effective Skyrme interactions which yield 'good' optical potentials at zero temperature. The results for nuclear matter (symmetric and asymmetric) are applied within the local density approximation of finite nuclei at various temperatures. Because of the limitation due to zero-range forces used and the assumptions of temperature independent nuclear densities and effective Skyrme interactions made, the calculations are expected to be limited to nucleon energies between 10 and 50 MeV above the Fermi energy and to nuclear temperatures of less than 8 MeV. (orig.)

  20. In vitro activation of bone with 14 MeV neutrons

    International Nuclear Information System (INIS)

    Holmberg, P.; Hyvoenen, M.; Tarvainen, M.

    1978-01-01

    Samples of compact bone, bone marrow and spongiosa of cow femur have been irradiated in vitro with 14 MeV neutrons. The Ca/P ratio for compact bone was found to be 2.16+-0.24. The suitability of using 14 MeV neutrons and the 31 P(n, α) 28 Al reaction for studying the bone mineral composition in vitro is discussed. It was demonstrated that 14 MeV neutrons can be used for the determination of calcium and phosphorus in bone with the aid of the 44 Ca(n, p) 44 K and 31 P(n, α) 28 Al reactions, respectively. As the Ca/P ratio for compact bone is known, the calcium content can be deduced indirectly from a determination of the phosphorus. This method has the advantage of not requiring moderator materials, as in the case when the 48 Ca(n, γ) 49 Ca reaction is employed. The half-life of the 28 Al activity is short (T=2.243 m) so that only short irradiation times are necessary. (T.G.)

  1. Dynamics of modification of Ni/n-GaN Schottky barrier diodes irradiated at low temperature by 200 MeV Ag14+ ions

    International Nuclear Information System (INIS)

    Kumar, Ashish; Kumar, Tanuj; Kanjilal, D.; Hähnel, A.; Singh, R.

    2014-01-01

    Ni/GaN Schottky barrier diodes were irradiated with 200 MeV Ag ions up to fluence of 1 × 10 11 ions/cm 2 at the substrate temperature of 80 K. Post-irradiation current-voltage measurements showed that the ideality factor, n increased and the reverse leakage current, I R decreased with increase in fluence. But Schottky barrier height, ϕ b increased only marginally with increase in ion fluence. In situ resistivity measurements showed orders of magnitude increase in resistivity of GaN epitaxial film with irradiation fluence. Cross-sectional transmission electron microscopy images revealed the presence of defect clusters in bulk GaN after irradiation

  2. Communication of nuclear data progress No. 24 (2000)

    International Nuclear Information System (INIS)

    2000-12-01

    Communication of Nuclear Data Progress (CNDP) in English is set up by Chinese Nuclear Data Center. The 24th issue of CNDP includes the measurements of cross sections of 75 As(n, γ) 76 As reaction from 0.50 to 1.50 MeV; theoretical calculations of n + 10,11 B, 16 O, 144,147-152,154 Sm, 238 Pu, 241,242 Am reactions in the energy region below 20 MeV; evaluations of n + 127,135 I, 129,131,132,134-136 Xe, 176-180,Nat Hf, 206 Pb, 240 Pu reactions; the effect of the charge distribution in nucleus on the calculation of highly ionized atoms; construction of covariance matrix for measured relative fission yield data and WWW chart of the nuclides

  3. Effects produced in GaAs by MeV ion bombardment

    International Nuclear Information System (INIS)

    Wie, C.R.

    1985-01-01

    The first part of this thesis presents work performed on the ionizing energy beam induced adhesion enhancement of thin (approx.500 A) Au films on GaAs substrates. The ionizing beam, employed in the present thesis, is the MeV ions (i.e., 16 O, 19 F, and 35 Cl), with energies between 1 and 20 MeV. Using the Scratch test for adhesion measurement, and ESCA for chemical analysis of the film substrate interface, the native oxide layer at the interface is shown to play an important role in the adhesion enhancement by the ionizing radiation. A model is discussed that explains the experimental data on the dependence of adhesion enhancement on the energy which was deposited into electronic processes at the interface. The second part of the thesis presents research results on the radiation damage in GaAs crystals produced by MeV ions. Lattice parameter dilatation in the surface layers of the GaAs crystals becomes saturated after a high dose bombardment at room temperature. The strain produced by nuclear collisions is shown to relax partially due to electronic excitation (with a functional dependence on the nuclear and electronic stopping power of bombarding ions. Data on the GaAs and GaP crystals suggest that low temperature recovery stage defects produce major crystal distortion

  4. Bath temperature effect on magnetoelectric performance of Ni-lead zirconate titanate-Ni laminated composites synthesized by electroless deposition

    Energy Technology Data Exchange (ETDEWEB)

    Wu, W. [College of Materials Science and Technology, Nanjing University of Aeronautics and Astronautics, Nanjing 210016 (China); Wang, Y.G., E-mail: yingang.wang@nuaa.edu.c [College of Materials Science and Technology, Nanjing University of Aeronautics and Astronautics, Nanjing 210016 (China); Bi, K. [College of Materials Science and Technology, Nanjing University of Aeronautics and Astronautics, Nanjing 210016 (China)

    2011-03-15

    Magnetoelectric (ME) Ni-lead zirconate titanate-Ni laminated composites have been prepared by electroless deposition at various bath temperatures. The structure of the Ni layers deposited at various bath temperatures was characterized by X-ray diffraction, and microstructures were investigated by transmission electron microscopy. The magnetostrictive coefficients were measured by means of a resistance strain gauge. The transverse ME voltage coefficient {alpha}{sub E,31} was measured with the magnetic field applied parallel to the sample plane. The deposition rate of Ni increases with bath temperature. Ni layer with smaller grain size is obtained at higher bath temperature and shows higher piezomagnetic coefficient, promoting the ME effect of corresponding laminated composites. It is advantageous to increase the bath temperature, while trying to avoid the breaking of bath constituents. - Research Highlights: Laminated composites without interlayer are prepared by electroless deposition. Bath temperature affects the grain size of the deposited Ni layers. Higher bath temperature is beneficial to obtain stronger ME response.

  5. Effect of Stacking Layup on Spring-back Deformation of Symmetrical Flat Laminate Composites Manufactured through Autoclave Processing

    Science.gov (United States)

    Nasir, M. N. M.; Seman, M. A.; Mezeix, L.; Aminanda, Y.; Rivai, A.; Ali, K. M.

    2017-03-01

    The residual stresses that develop within fibre-reinforced laminate composites during autoclave processing lead to dimensional warpage known as spring-back deformation. A number of experiments have been conducted on flat laminate composites with unidirectional fibre orientation to examine the effects of both the intrinsic and extrinsic parameters on the warpage. This paper extends the study on to the symmetrical layup effect on spring-back for flat laminate composites. Plies stacked at various symmetrical sequences were fabricated to observe the severity of the resulting warpage. Essentially, the experimental results demonstrated that the symmetrical layups reduce the laminate stiffness in its principal direction compared to the unidirectional laminate thus, raising the spring-back warpage with the exception of the [45/-45]S layup due to its quasi-isotropic property.

  6. Nanostructural studies on monoelaidin-water systems at low temperatures.

    Science.gov (United States)

    Kulkarni, Chandrashekhar V

    2011-10-04

    In recent years, lipid based nanostructures have increasingly been used as model membranes to study various complex biological processes. For better understanding of such phenomena, it is essential to gain as much information as possible for model lipid structures under physiological conditions. In this paper, we focus on one of such lipids--monoelaidin (ME)--for its polymorphic nanostructures under varying conditions of temperature and water content. In the recent contribution (Soft Matter, 2010, 6, 3191), we have reported the phase diagram of ME above 30 °C and compared with the phase behavior of other lipids including monoolein (MO), monovaccenin (MV), and monolinolein (ML). Remarkable phase behavior of ME, stabilizing three bicontinuous cubic phases, motivates its study at low temperatures. Current studies concentrate on the low-temperature (ME and subsequent reconstruction of its phase diagram over the entire temperature-water composition space (temperature, 0-76 °C; and water content, 0-70%). The polymorphs found for the monoelaidin-water system include three bicontinuous cubic phases, i.e., Ia3d, Pn3m, and Im3m, and lamellar phases which exhibit two crystalline (L(c1) and L(c0)), two gel (L(β) and L(β*)), and a fluid lamellar (L(α)) states. The fluid isotropic phase (L(2)) was observed only for lower hydrations (<20%), whereas hexagonal phase (H(2)) was not found under studied conditions. Nanostructural parameters of these phases as a function of temperature and water content are presented together with some molecular level calculations. This study might be crucial for perception of the lyotropic phase behavior as well as for designing nanostructural assemblies for potential applications. © 2011 American Chemical Society

  7. Bragg polaritons in a ZnSe-based unfolded microcavity at elevated temperatures

    Energy Technology Data Exchange (ETDEWEB)

    Sebald, K.; Rahman, SK. S.; Cornelius, M.; Kaya, T.; Gutowski, J. [Semiconductor Optics, Institute of Solid State Physics, University of Bremen, 28334 Bremen (Germany); Klein, T.; Gust, A.; Hommel, D. [Semiconductor Epitaxy, Institute of Solid State Physics, University of Bremen, 28334 Bremen (Germany); Klembt, S. [Institut Néel, Université Grenoble Alpes and CNRS, B.P. 166, 38042 Grenoble (France)

    2016-03-21

    In this contribution, we present strong coupling of ZnSe quantum well excitons to Bragg modes resulting in the formation of Bragg polariton eigenstates, characterized by a small effective mass in comparison to a conventional microcavity. We observe an anticrossing of the excitonic and the photonic component in our sample being a clear signature for the strong-coupling regime. The anticrossing is investigated by changing the detuning between the excitonic components and the Bragg mode. We find anticrossings between the first Bragg mode and the heavy- as well as light-hole exciton, respectively, resulting in three polariton branches. The observed Bragg-polariton branches are in good agreement with theoretical calculations. The strong indication for the existence of strong coupling is traceable up to a temperature of 200 K, with a Rabi-splitting energy of 24meV and 13 meV for the Bragg mode with the heavy- and light-hole exciton, respectively. These findings demonstrate the advantages of this sample configuration for ZnSe-based devices for the strong coupling regime.

  8. Depth distribution of damage in copper irradiated with MeV, Ni and He ions

    International Nuclear Information System (INIS)

    Narayan, J.; Noggle, T.S.; Oen, O.S.

    1975-01-01

    Transmission electron microscopy was used to study radiation damage as a function of depth caused by 58 and 4-MeV 58 Ni and 1-MeV He ions in copper single crystals at ambient temperature. The experimental damage density vs penetration depth distributions were compared with calculations based on the atomic collision theory of Lindhard et al. (LSS). For 58-MeV Ni ions, the calculated damage profile using the theoretical LSS value of the electronic stopping parameter (k = 0.167) agrees well with experiment. However, for 4-MeV Ni ions it is necessary to use k = 0.12 to get agreement with the experimental data. In the case of 1-MeV He, the depth location of the calculated damage peak is in good agreement with experiment when the electronic stopping determined by Chu and Powers is used whereas it is about 15 percent too close to the surface using the tables of Northcliffe and Schilling. (auth)

  9. Copper(II) oxide solubility behavior in aqueous sodium phosphate solutions at elevated temperatures

    International Nuclear Information System (INIS)

    Ziemniak, S.E.; Jones, M.E.; Combs, K.E.S.

    1990-02-01

    A platinum-lined, flowing autoclave facility is used to investigate the solubility behavior of copper(II) oxide (CuO) in aqueous sodium phosphate solutions at temperatures between 292 and 535 K. Copper solubilities are observed to increase continuously with temperature and phosphate concentration. The measured solubility is examined via a Cu(II) ion hydrolysis/complexing model and thermodynamic functions for the hydrolysis/complexing reactions are obtained from a least- squares analysis of the data. Altogether, thermochemical properties are established for five anionic complexes: Cu(OH) 3 - , Cu(OH) 4 = , Cu(OH) 2 (HPO 4 ) = , Cu(OH) 3 (H 2 PO 4 ) = , and Cu(OH) 2 (PO 4 ) ≡ . Precise thermochemical parameters are also derived for the Cu(OH) + hydroxocomplex based on CuO solubility behavior previously observed in pure water (*) at elevated temperatures. The relative ease of Cu(II) ion hydrolysis is such that Cu(OH) 3 - species become the preferred hydroxocomplex for pH ≥ 9.4. 20 refs., 8 figs., 6 tabs

  10. Perspective technologies of complex reprocessing of molybdenite concentrates

    International Nuclear Information System (INIS)

    Sobol', S.I.; Shcherbakov, V.A.; Gedgagov, Eh.I.

    1991-01-01

    The paper deals with a new investigations of autoclave technology. Utilization of one of the most important properties of molybdenite - its high hydropholy-enabled an improvement of specific autoclave leaching output, ensuring a high level of extraction. A possibility to limit direct molybdenum extraction by 70-80% which reduce leaching time 2-4 times

  11. Targeted Temperature Management for 48 vs 24 Hours and Neurologic Outcome After Out-of-Hospital Cardiac Arrest

    DEFF Research Database (Denmark)

    Kirkegaard, Hans; Søreide, Eldar; de Haas, Inge

    2017-01-01

    Importance: International resuscitation guidelines recommend targeted temperature management (TTM) at 33°C to 36°C in unconscious patients with out-of-hospital cardiac arrest for at least 24 hours, but the optimal duration of TTM is uncertain. Objective: To determine whether TTM at 33°C for 48....... Secondary outcomes included 6-month mortality, including time to death, the occurrence of adverse events, and intensive care unit resource use. Results: In 355 patients who were randomized (mean age, 60 years; 295 [83%] men), 351 (99%) completed the trial. Of these patients, 69% (120/175) in the 48-hour.......5%; 95% CI, -16.1% to 3.1%; RR, 0.81; 95% CI, 0.59-1.11; P = .19). There was no significant difference in the time to mortality between the 48-hour group and the 24-hour group (hazard ratio, 0.79; 95% CI, 0.54-1.15; P = .22). Adverse events were more common in the 48-hour group (97%) than in the 24-hour...

  12. MeSH Now: automatic MeSH indexing at PubMed scale via learning to rank.

    Science.gov (United States)

    Mao, Yuqing; Lu, Zhiyong

    2017-04-17

    MeSH indexing is the task of assigning relevant MeSH terms based on a manual reading of scholarly publications by human indexers. The task is highly important for improving literature retrieval and many other scientific investigations in biomedical research. Unfortunately, given its manual nature, the process of MeSH indexing is both time-consuming (new articles are not immediately indexed until 2 or 3 months later) and costly (approximately ten dollars per article). In response, automatic indexing by computers has been previously proposed and attempted but remains challenging. In order to advance the state of the art in automatic MeSH indexing, a community-wide shared task called BioASQ was recently organized. We propose MeSH Now, an integrated approach that first uses multiple strategies to generate a combined list of candidate MeSH terms for a target article. Through a novel learning-to-rank framework, MeSH Now then ranks the list of candidate terms based on their relevance to the target article. Finally, MeSH Now selects the highest-ranked MeSH terms via a post-processing module. We assessed MeSH Now on two separate benchmarking datasets using traditional precision, recall and F 1 -score metrics. In both evaluations, MeSH Now consistently achieved over 0.60 in F-score, ranging from 0.610 to 0.612. Furthermore, additional experiments show that MeSH Now can be optimized by parallel computing in order to process MEDLINE documents on a large scale. We conclude that MeSH Now is a robust approach with state-of-the-art performance for automatic MeSH indexing and that MeSH Now is capable of processing PubMed scale documents within a reasonable time frame. http://www.ncbi.nlm.nih.gov/CBBresearch/Lu/Demo/MeSHNow/ .

  13. Temperature dependent energy levels of methylammonium lead iodide perovskite

    Energy Technology Data Exchange (ETDEWEB)

    Foley, Benjamin J.; Marlowe, Daniel L.; Choi, Joshua J., E-mail: jjc6z@virginia.edu, E-mail: mgupta@virginia.edu, E-mail: scudiero@wsu.edu [Department of Chemical Engineering, University of Virginia, Charlottesville, Virginia 22904 (United States); Sun, Keye; Gupta, Mool C., E-mail: jjc6z@virginia.edu, E-mail: mgupta@virginia.edu, E-mail: scudiero@wsu.edu [Department of Electrical and Computer Engineering, University of Virginia, Charlottesville, Virginia 22904 (United States); Saidi, Wissam A. [Department of Mechanical Engineering and Materials Science, University of Pittsburgh, Pittsburgh, Pennsylvania 15261 (United States); Scudiero, Louis, E-mail: jjc6z@virginia.edu, E-mail: mgupta@virginia.edu, E-mail: scudiero@wsu.edu [Chemistry Department and Materials Science and Engineering Program, Washington State University, Pullman, Washington 99164 (United States)

    2015-06-15

    Temperature dependent energy levels of methylammonium lead iodide are investigated using a combination of ultraviolet photoemission spectroscopy and optical spectroscopy. Our results show that the valence band maximum and conduction band minimum shift down in energy by 110 meV and 77 meV as temperature increases from 28 °C to 85 °C. Density functional theory calculations using slab structures show that the decreased orbital splitting due to thermal expansion is a major contribution to the experimentally observed shift in energy levels. Our results have implications for solar cell performance under operating conditions with continued sunlight exposure and increased temperature.

  14. Rhythmic 24 h variation of core body temperature and locomotor activity in a subterranean rodent (Ctenomys aff. knighti, the tuco-tuco.

    Directory of Open Access Journals (Sweden)

    Patricia Tachinardi

    Full Text Available The tuco-tuco Ctenomys aff. knighti is a subterranean rodent which inhabits a semi-arid area in Northwestern Argentina. Although they live in underground burrows where environmental cycles are attenuated, they display robust, 24 h locomotor activity rhythms that are synchronized by light/dark cycles, both in laboratory and field conditions. The underground environment also poses energetic challenges (e.g. high-energy demands of digging, hypoxia, high humidity, low food availability that have motivated thermoregulation studies in several subterranean rodent species. By using chronobiological protocols, the present work aims to contribute towards these studies by exploring day-night variations of thermoregulatory functions in tuco-tucos, starting with body temperature and its temporal relationship to locomotor activity. Animals showed daily, 24 h body temperature rhythms that persisted even in constant darkness and temperature, synchronizing to a daily light/dark cycle, with highest values occurring during darkness hours. The range of oscillation of body temperature was slightly lower than those reported for similar-sized and dark-active rodents. Most rhythmic parameters, such as period and phase, did not change upon removal of the running wheel. Body temperature and locomotor activity rhythms were robustly associated in time. The former persisted even after removal of the acute effects of intense activity on body temperature by a statistical method. Finally, regression gradients between body temperature and activity were higher in the beginning of the night, suggesting day-night variation in thermal conductance and heat production. Consideration of these day-night variations in thermoregulatory processes is beneficial for further studies on thermoregulation and energetics of subterranean rodents.

  15. Exclusive measurements of light fragment production at forward angles in Ne-Pb and Ne-NaF collisions at E/A=400 MeV and 800 MeV

    International Nuclear Information System (INIS)

    Bastid, N.; Alard, J.P.; Arnold, J.; Augerat, J.; Biagi, F.; Crouau, M.; Charmensat, P.; Dupieux, P.; Fraysse, L.; Marroncle, J.; Montarou, G.; Parizet, M.J.; Qassoud, D.; Rahmani, A.; Schimmerling, W.

    1990-01-01

    Emission of light fragments at small angles is studied in relativistic heavy ion collisions using the Diogene plastic wall for both symmetrical and non-symmetrical target-projectile systems with 400 MeV per nucleon and 800 MeV per nucleon incident neon nuclei. Efficiency of multiplicity measurements in the small angle range for the selection of central or peripheral collisions is confirmed for asymmetric systems. Differential production cross sections of Z=1 fragments show evidence for the existence of two emitting sources. The apparent temperature of each source is obtained from comparison with a thermodynamical model. (orig.)

  16. Single proton knock-out from 24F

    International Nuclear Information System (INIS)

    Thoennessen, M.; Baumann, T.; Brown, B.A.; Enders, J.; Frank, N.H.; Hansen, P.G.; Heckman, P.; Luther, B.A.; Seitz, J.P.; Stolz, A.; Tryggestad, E.

    2004-01-01

    The measurement of the single proton knock-out reaction from 24 F on a 12 C target at 46.7 MeV/nucleon yielded a 23 O ground state population of (6.6+/-1.0) mb. The data were compared to calculations based on the many-body shell model and the eikonal theory. The results are consistent with a [0d5/26]-bar 1s1/2 configuration of 23 O

  17. Infrared profile of Milky Way at 2.4 μm

    International Nuclear Information System (INIS)

    Hayakawa, S.; Ito, K.; Matsumoto, T.; Ono, T.; Uyama, K.

    1976-01-01

    A balloon observation was made of infrared radiation from the Milky Way at wavelength 2.4 μm, with a band width of 0.1 μm, avoiding intense OH airglow. The telescope employed is described. The optical system was cooled by liquid N 2 to reduce the background thermal radiation and improve the detector sensitivity. An array of three PbS detectors was employed. An isophoto of the infrared surface brightness is shown. It appeared that some infrared sources are associated with objects in the spiral arms, but a considerable fraction of these sources is distributed over the galaxy in a similar manner to normal stars. An analysis of the results suggests that the infrared radiation observed at 2.4 μm is emitted mainly from the region inside the solar circle. A comparison was made with the intensity of 100 MeV γ-rays, produced by collisions of cosmic rays with interstellar matter. The longitude dependences observed for the 2.4 μm radiation, the 2.6 mm CO line, HII regions, the 21 cm H line, and the 100 MeV γ-rays correlated with one another. It is concluded that infrared emission provides a further means of investigating galactic structure. (U.K.)

  18. Destruction of Spores on Building Decontamination Residue in a Commercial Autoclave▿

    Science.gov (United States)

    Lemieux, P.; Sieber, R.; Osborne, A.; Woodard, A.

    2006-01-01

    The U.S. Environmental Protection Agency conducted an experiment to evaluate the effectiveness of a commercial autoclave for treating simulated building decontamination residue (BDR). The BDR was intended to simulate porous materials removed from a building deliberately contaminated with biological agents such as Bacillus anthracis (anthrax) in a terrorist attack. The purpose of the tests was to assess whether the standard operating procedure for a commercial autoclave provided sufficiently robust conditions to adequately destroy bacterial spores bound to the BDR. In this study we investigated the effects of several variables related to autoclaving BDR, including time, temperature, pressure, item type, moisture content, packing density, packing orientation, autoclave bag integrity, and autoclave process sequence. The test team created simulated BDR from wallboard, ceiling tiles, carpet, and upholstered furniture, and embedded in the BDR were Geobacillus stearothermophilus biological indicator (BI) strips containing 106 spores and thermocouples to obtain time and temperature profile data associated with each BI strip. The results indicated that a single standard autoclave cycle did not effectively decontaminate the BDR. Autoclave cycles consisting of 120 min at 31.5 lb/in2 and 275°F and 75 min at 45 lb/in2 and 292°F effectively decontaminated the BDR material. Two sequential standard autoclave cycles consisting of 40 min at 31.5 lb/in2 and 275°F proved to be particularly effective, probably because the second cycle's evacuation step pulled the condensed water out of the pores of the materials, allowing better steam penetration. The results also indicated that the packing density and material type of the BDR in the autoclave could have a significant impact on the effectiveness of the decontamination process. PMID:17012597

  19. Detection of 14 MeV neutrons in high temperature environment up to 500 deg. C using 4H-SiC based diode detector

    Energy Technology Data Exchange (ETDEWEB)

    Szalkai, D.; Klix, A. [KIT- Karlsruhe Institute of Technology, Institute of Neutron Physics and Reactor Technology Karlsruhe 76344 (Germany); Ferone, R.; Issa, F.; Ottaviani, L.; Vervisch, V. [IM2NP, UMR CNRS 7334, Aix-Marseille University, Case 231 -13397 Marseille Cedex 20 (France); Gehre, D. [Inst. for Nucl.- and Particle-Phys., Dresden University of Technology, Dresden 01069 (Germany); Lyoussi, A. [CEA, DEN, Departement d' Etudes des Reacteurs, Service de Physique Experimentale, Laboratoire Dosimetrie Capteurs Instrumentation, 13108 Saint-Paul-lez-Durance (France)

    2015-07-01

    In reactor technology and industrial applications detection of fast and thermal neutrons plays a crucial role in getting relevant information about the reactor environment and neutron yield. The inevitable elevated temperatures make neutron yield measurements problematic. Out of the currently available semiconductors 4H-SiC seems to be the most suitable neutron detector material under extreme conditions due to its high heat and radiation resistance, large band-gap and lower cost of production than in case of competing diamond detectors. In the framework of the European I-Smart project, optimal {sup 4}H-SiC diode geometries were developed for high temperature neutron detection and have been tested with 14 MeV fast neutrons supplied by a deuterium-tritium neutron generator with an average neutron flux of 10{sup 10}-10{sup 11} n/(s*cm{sup 2}) at Neutron Laboratory of the Technical University of Dresden in Germany from room temperatures up to several hundred degrees Celsius. Based on the results of the diode measurements, detector geometries appear to play a crucial role for high temperature measurements up to 500 deg. C. Experimental set-ups using SiC detectors were constructed to simulate operation in the harsh environmental conditions found in the tritium breeding blanket of the ITER fusion reactor, which is planned to be the location of neutron flux characterization measurements in the near future. (authors)

  20. Thermal Dark Matter Below an MeV

    OpenAIRE

    Berlin, Asher; Blinov, Nikita

    2017-01-01

    We consider a class of models in which thermal dark matter is lighter than an MeV. If dark matter thermalizes with the Standard Model below the temperature of neutrino-photon decoupling, equilibration and freeze-out cools and heats the Standard Model bath comparably, alleviating constraints from measurements of the effective number of neutrino species. We demonstrate this mechanism in a model consisting of fermionic dark matter coupled to a light scalar mediator. Thermal dark matter can be as...

  1. The total neutron cross sections for 14N and 24Mg

    International Nuclear Information System (INIS)

    Bommer, J.

    This report contains tables of the total neutron cross sections of 14 N and 24 Mg as determined in a recent measurement for neutron energies between 1 and 5.3 MeV. Graphic representations and details on the evaluation of the cross sections are included. (orig.) [de

  2. EVOLUTION OF THE GLOBAL TEMPERATURE STRUCTURE OF THE SOLAR CORONA DURING THE MINIMUM BETWEEN SOLAR CYCLES 23 AND 24

    International Nuclear Information System (INIS)

    Nuevo, Federico A.; Vásquez, Alberto M.; Huang Zhenguang; Frazin, Richard; Manchester, Ward B. IV; Jin Meng

    2013-01-01

    The combination of differential emission measure tomography with extrapolation of the photospheric magnetic field allows determination of the electron density and electron temperature along individual magnetic field lines. This is especially useful in quiet-Sun (QS) plasmas where individual loops cannot otherwise be identified. In Paper I, this approach was applied to study QS plasmas during Carrington rotation (CR) 2077 at the minimum between solar cycles (SCs) 23 and 24. In that work, two types of QS coronal loops were identified: ''up'' loops in which the temperature increases with height, and ''down'' loops in which the temperature decreases with height. While the first ones were expected, the latter ones were a surprise and, furthermore, were found to be ubiquitous in the low-latitude corona. In the present work, we extend the analysis to 11 CRs around the last solar minimum. We found that the ''down'' population, always located at low latitudes, was maximum at the time when the sunspot number was minimum, and the number of down loops systematically increased during the declining phase of SC-23 and diminished during the rising phase of SC-24. ''Down'' loops are found to have systematically larger values of β than do ''up'' loops. These discoveries are interpreted in terms of excitation of Alfvén waves in the photosphere, and mode conversion and damping in the low corona

  3. Study of the /sup 12/N 2. 43 MeV level. [Differential cross sections; 44 MeV /sup 3/He; 52 MeV p

    Energy Technology Data Exchange (ETDEWEB)

    Cecil, F E; Shepard, J R; Sercely, R R; Peterson, R J [Colorado Univ., Boulder (USA). Nuclear Physics Lab.; King, N S.P. [California Univ., Davis (USA). Crocker Nuclear Lab.

    1976-10-11

    The differential cross sections have been measured for the reactions /sup 12/C(/sup 3/He, /sup 3/He')/sup 12/C(17.77 MeV 0/sup +/ T = 1) and /sup 12/C(/sup 3/He, t)/sup 12/N(2.43 MeV) at Esub(/sup 3/He) = 44 MeV. The similar shapes of the angular distributions and the relative magnitudes of the cross sections suggest that the /sup 12/N 2.43 MeV level is the 0/sup +/ T = 1 analog to the /sup 12/C 17.77 MeV level. The reaction /sup 14/N(p, t)/sup 12/N(2.43 MeV) at Esub(p) = 52 MeV is also studied. The strength with which this level is excited in this reaction is consistent with reasonable two-step calculations assuming the 2.43 MeV level to have Jsup(..pi..) = 0/sup +/.

  4. Finite temperature effects on monopole and dipole excitations

    International Nuclear Information System (INIS)

    Niu, Y F; Paar, N; Vretenar, D; Meng, J

    2011-01-01

    The relativistic random phase approximation based on effective Lagrangian with density dependent meson-nucleon couplings has been extended to finite temperature and employed in studies of multipole excitations within the temperature range T = 1 - 2 MeV. The model calculations showed that isoscalar giant monopole and isovector giant dipole resonances are only slightly modified with temperature, but additional transition strength appears at low energies because of thermal unblocking of single-particle orbitals close to the Fermi level. The analysis of low-lying states shows that isoscalar monopole response in 132 Sn results from single particle transitions, while the isovector dipole strength for 60 Ni, located around 10 MeV, is composed of several single particle transitions, accumulating a small degree of collectivity.

  5. DESTRUCTION OF TETRAPHENYLBORATE IN TANK 48H USING WET AIR OXIDATION BATCH BENCH SCALE AUTOCLAVE TESTING WITH ACTUAL RADIOACTIVE TANK 48H WASTE

    Energy Technology Data Exchange (ETDEWEB)

    Adu-Wusu, K; Paul Burket, P

    2009-03-31

    Wet Air Oxidation (WAO) is one of the two technologies being considered for the destruction of Tetraphenylborate (TPB) in Tank 48H. Batch bench-scale autoclave testing with radioactive (actual) Tank 48H waste is among the tests required in the WAO Technology Maturation Plan. The goal of the autoclave testing is to validate that the simulant being used for extensive WAO vendor testing adequately represents the Tank 48H waste. The test objective was to demonstrate comparable test results when running simulated waste and real waste under similar test conditions. Specifically: (1) Confirm the TPB destruction efficiency and rate (same reaction times) obtained from comparable simulant tests, (2) Determine the destruction efficiency of other organics including biphenyl, (3) Identify and quantify the reaction byproducts, and (4) Determine off-gas composition. Batch bench-scale stirred autoclave tests were conducted with simulated and actual Tank 48H wastes at SRNL. Experimental conditions were chosen based on continuous-flow pilot-scale simulant testing performed at Siemens Water Technologies Corporation (SWT) in Rothschild, Wisconsin. The following items were demonstrated as a result of this testing. (1) Tetraphenylborate was destroyed to below detection limits during the 1-hour reaction time at 280 C. Destruction efficiency of TPB was > 99.997%. (2) Other organics (TPB associated compounds), except biphenyl, were destroyed to below their respective detection limits. Biphenyl was partially destroyed in the process, mainly due to its propensity to reside in the vapor phase during the WAO reaction. Biphenyl is expected to be removed in the gas phase during the actual process, which is a continuous-flow system. (3) Reaction byproducts, remnants of MST, and the PUREX sludge, were characterized in this work. Radioactive species, such as Pu, Sr-90 and Cs-137 were quantified in the filtrate and slurry samples. Notably, Cs-137, boron and potassium were shown as soluble as a

  6. Love me, love me not: changed names

    OpenAIRE

    2010-01-01

    Tiré du site Internet de Onestar Press: " A selection of 150 cities within Slavs and Tatars’ Eurasian remit, Love Me, Love Me Not : Changed Names plucks the petals off the past to reveal an impossibly thorny stem : a lineage of names changed by the course of the region’s grueling history. Some cities divulge a resolutely Asian heritage, so often forgotten in today’s quest, at all costs, for European integration. Some vacillate almost painfully, and others with numbing repetition, entire metro...

  7. Extended follow-up following a phase 2b randomized trial of the candidate malaria vaccines FP9 ME-TRAP and MVA ME-TRAP among children in Kenya.

    Directory of Open Access Journals (Sweden)

    Philip Bejon

    2007-08-01

    Full Text Available "FFM ME-TRAP" is sequential immunisation with two attenuated poxvirus vectors (FP9 and modified vaccinia virus Ankara delivering the pre-erythrocytic malaria antigen ME-TRAP. Over nine months follow-up in our original study, there was no evidence that FFM ME-TRAP provided protection against malaria. The incidence of malaria was slightly higher in children who received FFM ME-TRAP, but this was not statistically significant (hazard ratio 1.5, 95% CI 1.0-2.3. Although the study was unblinded, another nine months follow-up was planned to monitor the incidence of malaria and other serious adverse events.405 children aged 1-6 yrs were initially randomized to vaccination with either FFM ME-TRAP or control (rabies vaccine. 380 children were still available for follow-up after the first nine months. Children were seen weekly and whenever they were unwell for nine months monitoring. The axillary temperature was measured, and blood films taken when febrile. The primary analysis was time to parasitaemia >2,500/microl. During the second nine months monitoring, 49 events met the primary endpoint (febrile malaria with parasites >2,500/microl in the Intention To Treat (ITT group. 23 events occurred among the 189 children in the FFM ME-TRAP group, and 26 among the 194 children in the control group. In the full 18 months of monitoring, there were 63 events in the FFM ME-TRAP group and 60 in the control group (HR = 1.2, CI 0.84-1.73, p = 0.35. There was no evidence that the HR changed over the 18 months (test for interaction between time and vaccination p = 0.11.Vaccination with FFM ME-TRAP was not protective against malaria in this study. Malaria incidence during 18 months of surveillance was similar in both vaccine groups.Controlled-Trials.com ISRCTN88335123.

  8. Clay-based geothermal drilling fluids

    Energy Technology Data Exchange (ETDEWEB)

    Guven, N.; Carney, L.L.; Lee, L.J.; Bernhard, R.P.

    1982-11-01

    The rheological properties of fluids based on fibrous clays such as sepiolite and attapulgite have been systematically examined under conditions similar to those of geothermal wells, i.e. at elevated temperatures and pressures in environments with concentrated brines. Attapulgite- and sepiolite-based fluids have been autoclaved at temperatures in the range from 70 to 800/sup 0/F with the addition of chlorides and hydroxides of Na, K, Ca, and Mg. The rheological properties (apparent and plastic viscosity, fluid loss, gel strength, yield point, and cake thickness) of the autoclaved fluids have been studied and correlated with the chemical and physical changes that occur in the clay minerals during the autoclaving process.

  9. Energy monitoring device for 1.5-2.4 MeV electron beams

    Energy Technology Data Exchange (ETDEWEB)

    Fuochi, P.G., E-mail: fuochi@isof.cnr.i [CNR-ISOF, Via P. Gobetti 101, I-40129 Bologna (Italy); Lavalle, M.; Martelli, A. [CNR-ISOF, Via P. Gobetti 101, I-40129 Bologna (Italy); Kovacs, A. [Institute of Isotopes, HAS, P.O.Box 77, H-1525 Budapest (Hungary); Mehta, K. [Arbeiterstrandbad Strasse 72, Vienna, A-1210 (Austria); Kuntz, F.; Plumeri, S. [Aerial, Parc d' Innovation Rue Laurent Fries F-67400 Illkirch (France)

    2010-03-11

    An easy-to-use and robust energy monitoring device has been developed for reliable detection of day-to-day small variations in the electron beam energy, a critical parameter for quality control and quality assurance in industrial radiation processing. It has potential for using on-line, thus providing real-time information. Its working principle is based on the measurement of currents, or charges, collected by two aluminium absorbers of specific thicknesses (dependent on the beam energy), insulated from each other and positioned within a faraday cup-style aluminium cage connected to the ground. The device has been extensively tested in the energy range of 4-12 MeV under standard laboratory conditions at Institute of Isotopes and CNR-ISOF using different types of electron accelerators; namely, a TESLA LPR-4 LINAC (3-6 MeV) and a L-band Vickers LINAC (7-12 MeV), respectively. This device has been also tested in high power electron beam radiation processing facilities, one equipped with a 7-MeV LUE-8 linear accelerator used for crosslinking of cables and medical device sterilization, and the other equipped with a 10 MeV Rhodotron TT100 recirculating accelerator used for in-house sterilization of medical devices. In the present work, we have extended the application of this method to still lower energy region, i.e. from 1.5 to 2.4 MeV. Also, we show that such a device is capable of detecting deviation in the beam energy as small as 40 keV.

  10. Energy monitoring device for 1.5-2.4 MeV electron beams

    Science.gov (United States)

    Fuochi, P. G.; Lavalle, M.; Martelli, A.; Kovács, A.; Mehta, K.; Kuntz, F.; Plumeri, S.

    2010-03-01

    An easy-to-use and robust energy monitoring device has been developed for reliable detection of day-to-day small variations in the electron beam energy, a critical parameter for quality control and quality assurance in industrial radiation processing. It has potential for using on-line, thus providing real-time information. Its working principle is based on the measurement of currents, or charges, collected by two aluminium absorbers of specific thicknesses (dependent on the beam energy), insulated from each other and positioned within a faraday cup-style aluminium cage connected to the ground. The device has been extensively tested in the energy range of 4-12 MeV under standard laboratory conditions at Institute of Isotopes and CNR-ISOF using different types of electron accelerators; namely, a TESLA LPR-4 LINAC (3-6 MeV) and a L-band Vickers LINAC (7-12 MeV), respectively. This device has been also tested in high power electron beam radiation processing facilities, one equipped with a 7-MeV LUE-8 linear accelerator used for crosslinking of cables and medical device sterilization, and the other equipped with a 10 MeV Rhodotron TT100 recirculating accelerator used for in-house sterilization of medical devices. In the present work, we have extended the application of this method to still lower energy region, i.e. from 1.5 to 2.4 MeV. Also, we show that such a device is capable of detecting deviation in the beam energy as small as 40 keV.

  11. Positron-electron decay of 28Si at an excitation energy of 50 MeV

    International Nuclear Information System (INIS)

    Buda, A.; Bacelar, J.C.; Balanda, A.; Ploeg, H. van der; Sujkowski, Z.; Woude, A. van der

    1993-01-01

    The electron-positron pair decay of 28 Si at 50 MeV excitation produced by the isospin T=0 (α+ 24 Mg) and the mixed isospin T=0, 1 ( 3 He+ 25 Mg) reactions has been studied using a special designed Positron-Electron pair spectrometer PEPSI. (orig.)

  12. The temperatures of negative pions in light ions collisions with carbon and tantalum nuclei at 4.2 A GeV/c

    International Nuclear Information System (INIS)

    Backovic, D.; Salihagic, D.; Simic, L.

    1991-01-01

    The slope of transverse momentum invariant spectra of the negative pions in the inelastic (d,α,C)+(C,Ta) collisions at 4.2xA GeV/c are studied. The temperatures of the negative pion are obtained in various rapidity intervals. In collisons with carbon going from fragmentation to the central rapidity region the temperature increases from 60 MeV to 110 MeV. ''Two-temperature'' shape of p p erpendicular spectra appears in interactions with the tantalum nucleus. The value of the first temperature remains almost constant (≅40 MeV) for different rapidities. And behaviour of the second temperature is similar to that observed in the light nuclei interactions (varying from 70 MeV up to 110 MeV). The experimental results are compared with calculations in the framework of the quark-gluon string model. The influence of resonances and intranuclear rescattering mechanism on values of temperatures is shown in different rapidity regions. The investigation has been performed at the Laboratory of High Energies, JINR

  13. Scalability of the LEU-Modified Cintichem Process: 3-MeV Van de Graaff and 35-MeV Electron Linear Accelerator Studies

    Energy Technology Data Exchange (ETDEWEB)

    Rotsch, David A. [Argonne National Lab. (ANL), Argonne, IL (United States). Nuclear Engineering Division; Brossard, Tom [Argonne National Lab. (ANL), Argonne, IL (United States). Nuclear Engineering Division; Roussin, Ethan [Argonne National Lab. (ANL), Argonne, IL (United States). Nuclear Engineering Division; Quigley, Kevin [Argonne National Lab. (ANL), Argonne, IL (United States). Nuclear Engineering Division; Chemerisov, Sergey [Argonne National Lab. (ANL), Argonne, IL (United States). Nuclear Engineering Division; Gromov, Roman [Argonne National Lab. (ANL), Argonne, IL (United States). Nuclear Engineering Division; Jonah, Charles [Argonne National Lab. (ANL), Argonne, IL (United States). Nuclear Engineering Division; Hafenrichter, Lohman [Argonne National Lab. (ANL), Argonne, IL (United States). Nuclear Engineering Division; Tkac, Peter [Argonne National Lab. (ANL), Argonne, IL (United States). Nuclear Engineering Division; Krebs, John [Argonne National Lab. (ANL), Argonne, IL (United States). Nuclear Engineering Division; Vandegrift, George F. [Argonne National Lab. (ANL), Argonne, IL (United States). Nuclear Engineering Division

    2016-10-31

    Molybdenum-99, the mother of Tc-99m, can be produced from fission of U-235 in nuclear reactors and purified from fission products by the Cintichem process, later modified for low-enriched uranium (LEU) targets. The key step in this process is the precipitation of Mo with α-benzoin oxime (ABO). The stability of this complex to radiation has been examined. Molybdenum-ABO was irradiated with 3 MeV electrons produced by a Van de Graaff generator and 35 MeV electrons produced by a 50 MeV/25 kW electron linear accelerator. Dose equivalents of 1.7–31.2 kCi of Mo-99 were administered to freshly prepared Mo-ABO. Irradiated samples of Mo-ABO were processed according to the LEU Modified-Cintichem process. The Van de Graaff data indicated good radiation stability of the Mo-ABO complex up to ~15 kCi dose equivalents of Mo-99 and nearly complete destruction at doses >24 kCi Mo-99. The linear accelerator data indicate that even at 6.2 kCi of Mo-99 equivalence of dose, the sample lost ~20% of Mo-99. The 20% loss of Mo-99 at this low dose may be attributed to thermal decomposition of the product from the heat deposited in the sample during irradiation.

  14. Alpha particles from the photodisintegration of 9Be in the photon energy region 18 to 26 MeV

    International Nuclear Information System (INIS)

    Buchnea, A.; Johnson, R.G.; McNeill, K.G.

    1978-01-01

    Alpha particles from the 9 Be(γ,n) 8 Be(16.6) and 9 Be(γ,α 0 ) 5 He reactions were studied in the photon energy region 18 to 26 MeV; the results yielded a combined integrated cross section of 13.1 +- 2 MeV mb and an upper limit on the integrated (γ,α 0 ) cross section of 4.0 MeV mb. This agrees within error with the integrated cross section of Becchi, Meneghetti, Sanzone, and Vitale, 10 +- 2 MeV mb, which would contain about 50% of any contribution from the (γ,α 0 ) reaction. These reactions together with the 9 Be(γ,n 1 ) 8 Be reaction (which has an integrated cross section of 2.4 +- 0.4 MeV mb) are the major reaction channels contributing to the total photoneutron cross section in this energy region. Their sum, 15.5 MeV mb, agrees well with the results of Nathans and Halpern and Hughes, Sambell, Muirhead, and Spicer but disagrees with that of Costa, Pasqualini, Piragino, and Roasio. (author)

  15. 70 MeV injector auto tuning system handbook

    International Nuclear Information System (INIS)

    Ellis, J.E.; Munn, R.W.; Sandels, E.G.

    1976-06-01

    The handbook is in three sections: (1) description and location; (2) operating instructions; and (3) design notes on the tank and debuncher auto tuning systems for the 70 MeV injector. The purpose of the auto tuning system is to maintain the 'tune' of the four tanks and debuncher to within a few Hz, stabilizing against changes of temperature and other physical factors affecting the resonant frequency of the tanks. (U.K.)

  16. Effect Of Ethylene Oxide, Autoclave and Ultra Violet Sterilizations On Surface Topography Of Pet Electrospun Fibers

    Directory of Open Access Journals (Sweden)

    Sebnem DUZYER

    2016-11-01

    Full Text Available The aim of this study to investigate the effects of different sterilization methods on electrospun polyester. Ethylene oxide (EO, autoclave (AU and ultraviolet (UV sterilization methods were applied to electrospun fibers produced from polyethylene terephthalate (PET solutions with concentrations of 10, 15 and 20 wt.%. The surface characteristics of the fibers were examined by scanning electron microscope (SEM, atomic force microscope (AFM, surface pore size studies and contact angle measurements. Differential scanning calorimetry (DSC tests were carried out to characterize the thermal properties. Fourier Transform Infrared spectroscopy (FTIR tests were performed to analyze the micro structural properties. SEM studies showed that different sterilization methods made significant changes on the surfaces of the fibers depending on the PET concentration. Although the effects were decreased with the increasing polymer concentration, the fiber structure was damaged especially with the EO sterilization. The contact angle values were decreased with the UV sterilization method the most.

  17. A dispersive optical model for n + 120Sn from -15 to +80 MeV and properties of neutron single-particle and single-hole states

    International Nuclear Information System (INIS)

    Chen Zemin; Walter, R L; Tornow, W; Weisel, G J; Howell, C R

    2004-01-01

    Data for σ(θ) and A y (θ) previously obtained at the Triangle Universities Nuclear Laboratory for 120 Sn(n, n) are combined with other measurements of σ(θ) and A y (θ) to create an elastic-scattering database from 9.9 to 24 MeV. In addition, relatively recent high-accuracy measurements of the neutron total cross section σ T for Sn from 5 to 80 MeV are combined with earlier σ T data to form a detailed σ T database from 0.24 to 80 MeV. All of these data are analysed in the framework of a dispersive optical model (DOM). The DOM is extended to negative energies to investigate properties of single-particle and single-hole bound states. The DOM also is used in calculations of compound-nucleus contributions to σ(θ), so that DOM predictions can be compared to σ(θ) measurements. Excellent agreement is obtained for the entire set of scattering data from 0.4 to 24 MeV, and for σ T values from 0.05 to 80 MeV. Calculations of bound-state quantities are compared to values derived from experiment for energies down to -15 MeV. Reasonable agreement for the binding energies is achieved, while the predicted spectroscopic factors disagree somewhat with the values found in stripping and pickup experiments. Finally, the DOM is modified to investigate two features (volume absorption that is asymmetric about the Fermi energy and zero absorption in the vicinity of the Fermi energy) that have been ignored in many DOM models. These modifications have little effect on the agreement of the calculations with the scattering data or with the bound-state quantities

  18. WATER TEMPERATURE and other data from PAUL in the Caribbean Sea from 1991-03-16 to 1991-03-24 (NODC Accession 9100075)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The data in this accession were collected in Carribbean Sea from Ship Paul between March 16, 1991 to March 24, 1991. The real time data of water temperature at...

  19. Buckling Testing and Analysis of Honeycomb Sandwich Panel Arc Segments of a Full-Scale Fairing Barrel: Comparison of In- and Out-of-Autoclave Facesheet Configurations

    Science.gov (United States)

    Pineda, Evan Jorge; Myers, David E.; Kosareo, Daniel N.; Zalewski, Bart F.; Kellas, Sotiris; Dixon, Genevieve D.; Krivanek, Thomas M.; Gyekenyesi, Thomas G.

    2014-01-01

    Four honeycomb sandwich panels, representing 1/16th arc segments of a 10-m diameter barrel section of the Heavy Lift Launch Vehicle, were manufactured and tested under the NASA Composites for Exploration and the NASA Constellation Ares V programs. Two configurations were chosen for the panels: 6-ply facesheets with 1.125 in. honeycomb core and 8-ply facesheets with 1.0 in. honeycomb core. Additionally, two separate carbon fiber/epoxy material systems were chosen for the facesheets: in-autoclave IM7/977-3 and out-of-autoclave T40-800b/5320-1. Smaller 3 ft. by 5 ft. panels were cut from the 1/16th barrel sections and tested under compressive loading. Furthermore, linear eigenvalue and geometrically nonlinear finite element analyses were performed to predict the compressive response of each 3 ft. by 5 ft. panel. To improve the robustness of the geometrically nonlinear finite element model, measured surface imperfections were included in the geometry of the model. Both the linear and nonlinear models yielded good qualitative and quantitative predictions. Additionally, it was correctly predicted that the panel would fail in buckling prior to failing in strength. Furthermore, several imperfection studies were performed to investigate the influence of geometric imperfections, fiber angle misalignments, and three-dimensional effects on the compressive response of the panel.

  20. EVOLUTION OF THE GLOBAL TEMPERATURE STRUCTURE OF THE SOLAR CORONA DURING THE MINIMUM BETWEEN SOLAR CYCLES 23 AND 24

    Energy Technology Data Exchange (ETDEWEB)

    Nuevo, Federico A.; Vasquez, Alberto M. [Instituto de Astronomia y Fisica del Espacio (CONICET-UBA) and FCEN (UBA), CC 67-Suc 28, Ciudad de Buenos Aires (Argentina); Huang Zhenguang; Frazin, Richard; Manchester, Ward B. IV; Jin Meng [Department of Atmospheric, Oceanic and Space Sciences, University of Michigan, Ann Arbor, MI 48109 (United States)

    2013-08-10

    The combination of differential emission measure tomography with extrapolation of the photospheric magnetic field allows determination of the electron density and electron temperature along individual magnetic field lines. This is especially useful in quiet-Sun (QS) plasmas where individual loops cannot otherwise be identified. In Paper I, this approach was applied to study QS plasmas during Carrington rotation (CR) 2077 at the minimum between solar cycles (SCs) 23 and 24. In that work, two types of QS coronal loops were identified: ''up'' loops in which the temperature increases with height, and ''down'' loops in which the temperature decreases with height. While the first ones were expected, the latter ones were a surprise and, furthermore, were found to be ubiquitous in the low-latitude corona. In the present work, we extend the analysis to 11 CRs around the last solar minimum. We found that the ''down'' population, always located at low latitudes, was maximum at the time when the sunspot number was minimum, and the number of down loops systematically increased during the declining phase of SC-23 and diminished during the rising phase of SC-24. ''Down'' loops are found to have systematically larger values of {beta} than do ''up'' loops. These discoveries are interpreted in terms of excitation of Alfven waves in the photosphere, and mode conversion and damping in the low corona.

  1. Actinide-carbon bonds: insertion reactions of carbon monoxide, tert-butyl isocyanide, and tert-butyl cyanide into [(Me3Si)2N]2MCH2Si(Me)2NSiMe3

    International Nuclear Information System (INIS)

    Simpson, S.J.; Andersen, R.A.

    1981-01-01

    The thorium or uranium metallacycles [(Me 2 Si) 2 N] 2 MCH 2 Si(Me) 2 NSiMe 3 (I) react with tert-butyl cyanide to give the six-membered ring compounds [(Me 3 Si) 2 N] 2 MN = C(t-Bu)CH 2 Si(Me) 2 NSiMe 3 . The metallacycles (I) also react with the isoelectronic molecules tert-butyl isocyanide and carbon monoxide to give the unique five-membered ring compounds with exocyclic carbon-carbon double bonds, [(Me 3 Si) 2 N] 2 MXC(=CH 2 )Si(Me) 2 NSiMe 3 , where X is t-BuN or oxygen. The four-membered ring metallacycles (I) give simple coordination complexes of the type [(Me 3 Si) 2 N] 2 MCH 2 Si-(Me) 2 NSiMe 3 (N 3 SiMe 3 ) with trimethylsilyl azide

  2. Effect of heat treatment and irradiation temperature on mechanical properties and structure of reduced-activation Cr-W-V steels of bainitic, martensitic, and martensitic-ferritic classes

    International Nuclear Information System (INIS)

    Gorynin, I.V.; Rybin, V.V.; Kursevich, I.P.; Lapin, A.N.; Nesterova, E.V.; Klepikov, E.Yu.

    2000-01-01

    Effects of molybdenum replacement by tungsten in steels of the bainitic, martensitic, and martensitic-ferritic classes containing 2.5%, 8% and 11% Cr, respectively, were investigated. The phase composition and structure of the bainitic steels were varied by changing the cooling rates from the austenitization temperature (from values typical for normalization up to V=3.3 x 10 -2 deg. C/s) and then tempering. The steels were irradiated to a fluence of 4x10 23 n/m 2 (≥0.5 MeV) at 270 deg. C and to fluences of 1.3x10 23 and 1.2x10 24 n/m 2 (≥0.5 MeV) at 70 deg. C. The 2.5Cr-1.4WV and 8Cr-1.5WV steels have shown lower values of the shifts in ductile-brittle transition temperature (DBTT) under irradiation in comparison with corresponding Cr-Mo steels. Radiation embrittlement at elevated irradiation temperature was lowest in bainitic 2.5Cr-1.4WV steel and martensitic-ferritic 11Cr-1.5WV steel. The positive effect of molybdenum replacement by tungsten at irradiation temperature ∼300 deg. C is reversed at T irr =70 deg. C

  3. Meshable: searching PubMed abstracts by utilizing MeSH and MeSH-derived topical terms.

    Science.gov (United States)

    Kim, Sun; Yeganova, Lana; Wilbur, W John

    2016-10-01

    Medical Subject Headings (MeSH(®)) is a controlled vocabulary for indexing and searching biomedical literature. MeSH terms and subheadings are organized in a hierarchical structure and are used to indicate the topics of an article. Biologists can use either MeSH terms as queries or the MeSH interface provided in PubMed(®) for searching PubMed abstracts. However, these are rarely used, and there is no convenient way to link standardized MeSH terms to user queries. Here, we introduce a web interface which allows users to enter queries to find MeSH terms closely related to the queries. Our method relies on co-occurrence of text words and MeSH terms to find keywords that are related to each MeSH term. A query is then matched with the keywords for MeSH terms, and candidate MeSH terms are ranked based on their relatedness to the query. The experimental results show that our method achieves the best performance among several term extraction approaches in terms of topic coherence. Moreover, the interface can be effectively used to find full names of abbreviations and to disambiguate user queries. https://www.ncbi.nlm.nih.gov/IRET/MESHABLE/ CONTACT: sun.kim@nih.gov Supplementary data are available at Bioinformatics online. © The Author 2016. Published by Oxford University Press.

  4. Temperature dependence of the magnetic excitation spectrum of Dy2Fe14B

    International Nuclear Information System (INIS)

    Loewenhaupt, M.; Fabi, P.; Sosnowska, I.; Frick, B.; Eccleston, R.

    1995-01-01

    We present inelastic magnetic neutron scattering spectra of polycrystalline Dy 2 Fe 14 B measured between 2 and 650 K employing different time-of-flight spectrometers. At the lowest temperatures we can identify in the magnetic excitation spectra the following features: (i) a dominant line at Δ=12 meV with a shoulder at 11.1 meV, and (ii) two weak lines at 3.8 and 5.5 meV. The temperature dependence of the average position Δ of the dominant line follows roughly the temperature dependence of the spontaneous magnetization of Y 2 Fe 14 B indicating that the energy of this mode is substantially fixed by the molecular fields of the surrounding Fe moments. Slight deviations, however, indicate that the Dy level spacing is not equidistant due to crystal field effects. ((orig.))

  5. Activity of bone morphogenetic protein-7 after treatment at various temperatures: freezing vs. pasteurization vs. allograft.

    Science.gov (United States)

    Takata, Munetomo; Sugimoto, Naotoshi; Yamamoto, Norio; Shirai, Toshiharu; Hayashi, Katsuhiro; Nishida, Hideji; Tanzawa, Yoshikazu; Kimura, Hiroaki; Miwa, Shinji; Takeuchi, Akihiko; Tsuchiya, Hiroyuki

    2011-12-01

    Insufficient bone union is the occasional complication of biomechanical reconstruction after malignant bone tumor resection using temperature treated tumor bearing bone; freezing, pasteurization, and autoclaving. Since bone morphogenetic protein (BMP) plays an important role in bone formation, we assessed the amount and activity of BMP preserved after several temperature treatments, including -196 and -73°C for 20 min, 60 and 100°C for 30 min, 60°C for 10h following -80°C for 12h as an allograft model, and 4°C as the control. The material extracted from the human femoral bone was treated, and the amount of BMP-7 was analyzed using an enzyme-linked immunosorbent assay. Then, the activity of recombinant human BMP-7 after the treatment was assessed using a bioassay with NIH3T3 cells and immunoblotting analysis to measure the amount of phospho-Smad, one of the signaling substrates that reflect the intracellular reaction of BMPs. Both experiments revealed that BMP-7 was significantly better preserved in the hypothermia groups. The percentages of the amount of BMP-7 in which the control group was set at 100% were 114%, 108%, 70%, 49%, and 53% in the -196, -73, 60, 100°C, and the allograft-model group, respectively. The percentages of the amount of phospho-Smad were 89%, 87%, 24%, 4.9%, and 14% in the -196, -73, 60, 100°C, and the allograft-model group, respectively. These results suggested that freezing possibly preserves osteoinductive ability than hyperthermia treatment. Copyright © 2011 Elsevier Inc. All rights reserved.

  6. Temperature evolution of subharmonic gap structures in MgB{sub 2}/Nb point-contacts

    Energy Technology Data Exchange (ETDEWEB)

    Giubileo, F. [CNR-INFM Laboratorio Regionale SUPERMAT e Dipartimento di Fisica ' E.R. Caianiello' , Universita degli Studi di Salerno, via Salvador Allende, 84081 Baronissi (Italy)], E-mail: giubileo@sa.infn.it; Bobba, F.; Scarfato, A.; Piano, S. [CNR-INFM Laboratorio Regionale SUPERMAT e Dipartimento di Fisica ' E.R. Caianiello' , Universita degli Studi di Salerno, via Salvador Allende, 84081 Baronissi (Italy); Aprili, M. [Laboratoire de Spectroscopie en Lumiere Polarisee, ESPCI, 10 rue Vauquelin, 75005 Paris (France); CSNSM-CNRS, Bat. 108 Universite Paris-Sud, 91405 Orsay (France); Cucolo, A.M. [CNR-INFM Laboratorio Regionale SUPERMAT e Dipartimento di Fisica ' E.R. Caianiello' , Universita degli Studi di Salerno, via Salvador Allende, 84081 Baronissi (Italy)

    2007-09-01

    We have performed point-contact spectroscopy experiments on superconducting micro-constrictions between Nb tips and high quality MgB{sub 2} pellets. We measured the temperature evolution (between 4.2 K and 300 K) of the current-voltage (I-V) and of the dynamical conductance (dI/dV-V) characteristics. Above the Nb critical temperature T{sub C}{sup Nb}, the conductance of the constrictions behaves as predicted by the BTK model for S/N contacts being Nb in its normal state below T{sub C}{sup Nb}, the contacts show Josephson current and subharmonic gap structures, due to multiple Andreev reflections. These observations clearly indicate the coupling of the MgB{sub 2} 3D {pi}-band with the Nb superconducting order parameter. We found {delta}{sub {pi}} = 2.4 {+-} 0.2 meV for the three-dimensional gap of MgB{sub 2}.

  7. Comparison of 4.2 MeV Fe+ and 46.5 MeV Ni6+ ion irradiation for the study of void swelling

    International Nuclear Information System (INIS)

    Blamires, N.G.; Worth, J.H.

    1975-11-01

    Void formation in pure nickel and 316 steel containing 10 ppm He has been studied using 4.2 MeV Fe+ ions from the Harwell Van de Graaff accelerator. The dose dependence of swelling in nickel at 525degC and the dose and temperature dependence of swelling in 316 steel is reported. The results are compared with those of other workers, especially those sup(13,14) using 46.5 MeV Ni 6+ ions. In general, there is good agment, except for a marked decrease in swelling of 316 steel at 650degC and 700degC compared with the Ni 6+ bombardment. The reason for this is thought to result from the restricted width of the damaged region in the low energy case which at the high temperatures is comparable with the inter-void spacing. Anomalous void distributions adjacent to grain boundaries are reported and are probably caused by grain boundary movement. Denuded zones at grain boundaries in 316 steel vary in width from approximatly 1300A at 450degC to approximatly 8800A at 700degC. The region adjacent to the surface of the nickel specimens exhibits an abnormally high swelling. Possible explanations are suggested

  8. Follicular dynamics, circulating progesterone, and fertility in Holstein cows synchronized with reused intravaginal progesterone implants that were sanitized by autoclave or chemical disinfection.

    Science.gov (United States)

    Melo, L F; Monteiro, P L J; Nascimento, A B; Drum, J N; Spies, C; Prata, A B; Wiltbank, M C; Sartori, R

    2018-04-01

    This experiment aimed to compare circulating progesterone (P4), follicular dynamics, and fertility during reuse of intravaginal P4 implants that were sanitized by autoclave or chemical disinfection in lactating Holstein cows submitted to fixed-time artificial insemination (FTAI). For this, 123 primiparous and 226 multiparous cows from 2 farms, averaging (mean ± standard deviation) 163.9 ± 141.9 d in milk, 35.7 ± 11.3 kg of milk/d, and a body condition score of 2.9 ± 0.5, were enrolled in the study. Cows were randomly assigned to 1 of 2 treatments using a completely randomized design and each cow received a reused implant (1.9 g of P4; previously used for 8 d) that was either autoclaved (AUT; n = 177) or chemically disinfected (CHEM; n = 172) on d -10. Also on d -10, cows received 2 mg of estradiol benzoate and 100 μg of GnRH. On d -3, cows received 25 mg of dinoprost (PGF 2α ). A second PGF 2α was given on d -2, along with 1 mg of estradiol cypionate and P4 implant removal. Cows received FTAI on d 0. A subset of cows (n = 143) was evaluated by ultrasound on d -10, -8, -6, -3, -2, 0, and 5 to identify ovarian structures, and blood was sampled on d -10, -3, and -2 for P4 concentrations by RIA. Pregnancy diagnoses were performed at d 32 and 60. Statistical analyses was performed using PROC-MIXED for continuous variables and PROC-GLIMMIX of SAS 9.4 (SAS Institute Inc., Cary, NC) for binomial variables. The treatments did not differ in circulating P4 on d -10 or -3, but P4 was greater on d -2 in CHEM cows. Ovulation to the treatments on d -10 was associated with lower circulating P4 on d -10 (2.0 vs. 3.1 ng/mL) and resulted in greater P4 on d -3 (4.0 vs. 2.4 ng/mL) and more cows with a corpus luteum on d -3 (100 vs. 40%) than nonovulating cows. Cows that ovulated to d -10 treatments were more likely to have a synchronized new follicular wave (97.9 vs. 63.2%) and had an earlier wave emergence (1.9 vs. 2.6 d), resulting in less cows ovulating a persistent follicle

  9. WATER TEMPERATURE and other data from DISCOVERY, CHARLES DARWIN and other platforms from 1987-08-24 to 1992-11-02 (NODC Accession 9300124)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The water depth and temperature data were collected from ships CHARLES DARWIN, CLYDE-OWS LIMA, DISCOVERY, and OCEAN WEATHER STATION L between August 24 1987 and...

  10. Temperature profile, pressure, and nutrients data from bottle in South Atlantic Ocean from 24 November 1987 to 12 March 1989 (NODC Accession 0000196)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Temperature profile, pressure, and nutrients data were collected using bottle in the South Atlantic Ocean from 24 November 1987 to 12 March 1989. Data were collected...

  11. Reversible Sigma C-C Bond Formation Between Phenanthroline Ligands Activated by (C5Me5)2Yb

    Energy Technology Data Exchange (ETDEWEB)

    Nocton, Gr& #233; gory; Lukens, Wayne W.; Booth, Corwin H.; Rozenel, Sergio S.; Medling, Scott A.; Maron, Laurent; Andersen, Richard A.

    2014-06-26

    The electronic structure and associated magnetic properties of the 1,10-phenanthroline adducts of Cp*2Yb are dramatically different from those of the 2,2?-bipyridine adducts. The monomeric phenanthroline adducts are ground state triplets that are based upon trivalent Yb(III), f13, and (phen ) that are only weakly exchange coupled, which is in contrast to the bipyridine adducts whose ground states are multiconfigurational, open-shell singlets in which ytterbium is intermediate valent ( J. Am. Chem. Soc 2009, 131, 6480; J. Am. Chem. Soc 2010, 132, 17537). The origin of these different physical properties is traced to the number and symmetry of the LUMO and LUMO+1 of the heterocyclic diimine ligands. The bipy has only one 1 orbital of b1 symmetry of accessible energy, but phen has two orbitals of b1 and a2 symmetry that are energetically accessible. The carbon p-orbitals have different nodal properties and coefficients and their energies, and therefore their populations change depending on the position and number of methyl substitutions on the ring. A chemical ramification of the change in electronic structure is that Cp 2Yb(phen) is a dimer when crystallized from toluene solution, but a monomer when sublimed at 180190 C. When 3,8-Me2phenanthroline is used, the adduct Cp*2Yb(3,8-Me2phen) exists in the solution in a dimer monomer equilibrium in which G is near zero. The adducts with 3-Me, 4-Me, 5-Me, 3,8-Me2, and 5,6-Me2-phenanthroline are isolated and characterized by solid state X-ray crystallography, magnetic susceptibility and LIII-edge XANES spectroscopy as a function of temperature and variable-temperature 1H NMR spectroscopy.

  12. Momentum transfer with light ions at energies from 70 MeV to 1000 MeV

    International Nuclear Information System (INIS)

    Saint Laurent, F.; Conjeaud, M.; Dayras, R.; Harar, S.; Oeschler, H.; Volant, C.

    1982-01-01

    Angular correlations of fission fragments induced by bombarding a 232 Th target with protons, deuterons and alpha particles of energies from 70 MeV to 1000 MeV have been measured. They give information about the forward momentum imparted to the fissioning nuclei. We present the average values of the transferred linear momentum ([p vertical stroke vertical stroke ]) as a function of the incident energy and propose a classification into three regimes of dominating processes leading to fission: (I) low-energy behaviour, for E/A less than 10 MeV/u [p vertical stroke vertical stroke ]/psub(i) approx. equal to 1. (II) Between 10 MeV/u and about 70 MeV/u, [p vertical stroke vertical stroke ]/psub(i) decreases progressively down to 0.5 but remains proportional to the projectile mass. (III) The region between 70 MeV/u and about 1000 MeV/u corresponds to a transition region where the projectiles, whatever their masses, tend to transfer the same momentum. (orig.)

  13. SAXS measurements of crystallization in Me PEEK

    International Nuclear Information System (INIS)

    Barberato, C.; Kellerman, G.; Craievich, A.F.; Torriani, I.L.

    1997-01-01

    Full text. Preliminary small-angle x-ray scattering (SAXS) measurements on a variety of methyl-substituted poly(aryl ether ether ketone) (Me PEEK) samples have been performed at the D11AA-SAXS beam line of the Brazilian National Synchrotron Light Laboratory (LNLS).Me PEEK is an industrially important thermoplastic material exhibiting crystallization upon annealing at temperatures between 175 and 200 deg C. Differential Scanning Calorimetry (DSC) measurements (Handa Y.P., Roovers, J., Wang, F., Macromolecules 27(19), 551-5516 (1994)) indicate that the presence of supercritical fluids during thermal treatment can have dramatic effects on the melting behavior of Me PEEK when compared to similar data for materials annealed in air. These observations have been made for samples demonstrating no significant differences in the extent of crystallinity suggesting that it is the nature of the crystallites that is affected by the presence of additives during the thermal treatment. In this preliminary study, scattering profiles for three Me PEEK samples (as received, thermally treated in air and thermally treated with supercritical 0.85 CO 2 +C H 3 O H gas) are obtained. The data are analyzed to provide some measure of the variation in crystallite structure between the thermally treated samples. Scattering data obtained in the very small-angle region on the same samples at the High Brilliance Beamline (ID2/BM4) experiments performed by Olivier Diat and M.A. Singh, Dec. 11996) of the European Synchrotron Radiation Facility (ESRF) is combined with the Brazilian National Laboratory on Synchrotron Light (LNLS) data to provide information over 3 decades of scattering angle. This work is part of a larger study of the use of supercritical fluids to control the level and morphology of crystallization in these materials. (author)

  14. The effect of Sn on autoclave corrosion performance and corrosion mechanisms in Zr–Sn–Nb alloys

    International Nuclear Information System (INIS)

    Wei, J.; Frankel, P.; Polatidis, E.; Blat, M.; Ambard, A.; Comstock, R.J.; Hallstadius, L.; Hudson, D.; Smith, G.D.W.; Grovenor, C.R.M.; Klaus, M.; Cottis, R.A.; Lyon, S.; Preuss, M.

    2013-01-01

    The desire to improve the corrosion resistance of Zr cladding material for high burn-up has resulted in a general trend among fuel manufacturers to develop alloys with reduced levels of Sn. While commonly accepted, the reason for the improved corrosion performance observed for low-tin zirconium alloys in high-temperature aqueous environments remains unclear. High-energy synchrotron X-ray diffraction was used to characterize the oxides formed by autoclave exposure on Zr–Sn–Nb alloys with tin concentration ranging from 0.01 to 0.92 wt.%. The alloys studied included the commercial alloy ZIRLO® (ZIRLO® is a registered trademark of Westinghouse Electric Company LLC in the USA and may be registered in other countries throughout the world. All rights reserved. Unauthorized use is strictly prohibited.) and two variants of ZIRLO with significantly lower tin levels, referred to here as A-0.6Sn and A-0.0Sn. The nature of the oxide grown on tube samples from each alloy was investigated via cross-sectional scanning electron microscopy. Atom probe analysis of ZIRLO demonstrated that the tin present in the alloy passes into the oxide as it forms, with no significant difference in the Sn/Zr ratio between the two. Synchrotron X-ray diffraction measurements on the oxides formed on each alloy revealed that the monoclinic and tetragonal oxide phases display highly compressive in-plane residual stresses with the magnitudes dependent on the phase and alloy. The amount of tetragonal phase present and, more importantly, the level of tetragonal-to-monoclinic phase transformation both decrease with decreasing tin levels, suggesting that tin is a tetragonal oxide phase stabilizing element. It is proposed that in Zr–Nb–Sn alloys with low Sn, the tetragonal phase is mainly stabilized by very small grain size and therefore remains stable throughout the corrosion process. In contrast, alloys with higher tin levels can in addition grow larger, stress stabilized, tetragonal grains that

  15. Little Boy neutron spectrum below 3 MeV

    International Nuclear Information System (INIS)

    Evans, A.E.; Bennett, E.F.; Yule, T.J.

    1984-01-01

    The leakage neutron spectrum from the Little Boy replica has been measured from 12 keV to 3 MeV using a high-resolution 3 He ionization chamber, and from 1 keV to 3 MeV using proton-recoil proportional counters. The 3 He-spectrometer measurements were made at distances of 0.75 and 2.0 m from the active center and at angles of 0 0 , 45 0 , and 90 0 with respect to the axis of the assembly. Proton-recoil measurments were made at 90 0 to the assembly axis at distances of 0.75 and 2.0 m, with a shielded measurement made at 2.0 m to estimate background due to scattering. The 3 He spectrometer was calibrated at Los Alamos using monoenergetic 7 Li(p,n) 7 Be neutrons to generate a family of response functions. The proton-recoil counters were calibrated at Argonne by studying the capture of thermal neutrons by nitrogen in the counters, by observation of the 24-keV neutron resonance in iron, and by relating to the known hydrogen content of the counters. The neutron spectrum from Little Boy was found to be highly structured, with peaks corresponding to minima in the iron total neutron cross section. In particular, influence of the 24-keV iron window was evident in both sets of spectra. The measurements provide information for dosimetry calculations and also a valuable intercomparison of neutron spectrometry using the two different detector types. Spectra measured with both detectors are in essential agreement. 8 references, 7 figures, 2 tables

  16. Fusion blanket high-temperature heat transfer

    International Nuclear Information System (INIS)

    Fillo, J.A.

    1983-01-01

    Deep penetration of 14 MeV neutrons makes two-temperature region blankets feasible. A relatively low-temperature (approx. 300 0 C) metallic structure is the vacuum/coolant pressure boundary, while the interior of the blanket, which is a simple packed bed of nonstructural material, operates at very high temperatures (>1000 0 C). The water-cooled shell structure is thermally insulated from the steam-cooled interior. High-temperature steam can dramatically increase the efficiency of electric power generation, as well as produce hydrogen and oxygen-based synthetic fuels at high-efficiency

  17. MeCrAl coatings obtained by arc PVD and pack cementation processes on nickel base superalloys

    International Nuclear Information System (INIS)

    Swadzba, L.; Maciejny, A.; Formanek, B.; Mendala, B.

    1997-01-01

    The paper presents the results of researches on obtaining and structure of high temperature resistance coatings on superalloys. The coatings were deposited on nickel and nickel base superalloys in two stages. During the first stage, the NiCr and NiCrHf coatings were obtained by arc-PVD method. Basic technology, bias, arc current, rotation, parameters of deposition of NiCr and MeCrHf coatings were defined. The high efficiency of deposition of both single and two sources was observed. The targets were made by vacuum melting and machining. An influence of targets chemical composition on coating structure and chemical coatings composition was described. The second stage was made by pack cementation HTLA (high temperature low activity) on 1323 K chromoaluminizing process. These arc-PVD and diffusion (pack cementation) connected processes permitted to obtain MeCrAl and MeCrAlHf type of coatings. The morphology, structure and microchemical composition were characterized by scanning electron microscopy, X-ray microanalysis, energy dispersive X-ray spectroscopy and X-ray diffraction methods. (orig.)

  18. Algorithm Development for Multi-Energy SXR based Electron Temperature Profile Reconstruction

    Science.gov (United States)

    Clayton, D. J.; Tritz, K.; Finkenthal, M.; Kumar, D.; Stutman, D.

    2012-10-01

    New techniques utilizing computational tools such as neural networks and genetic algorithms are being developed to infer plasma electron temperature profiles on fast time scales (> 10 kHz) from multi-energy soft-x-ray (ME-SXR) diagnostics. Traditionally, a two-foil SXR technique, using the ratio of filtered continuum emission measured by two SXR detectors, has been employed on fusion devices as an indirect method of measuring electron temperature. However, these measurements can be susceptible to large errors due to uncertainties in time-evolving impurity density profiles, leading to unreliable temperature measurements. To correct this problem, measurements using ME-SXR diagnostics, which use three or more filtered SXR arrays to distinguish line and continuum emission from various impurities, in conjunction with constraints from spectroscopic diagnostics, can be used to account for unknown or time evolving impurity profiles [K. Tritz et al, Bull. Am. Phys. Soc. Vol. 56, No. 12 (2011), PP9.00067]. On NSTX, ME-SXR diagnostics can be used for fast (10-100 kHz) temperature profile measurements, using a Thomson scattering diagnostic (60 Hz) for periodic normalization. The use of more advanced algorithms, such as neural network processing, can decouple the reconstruction of the temperature profile from spectral modeling.

  19. Double differential cross-sections of (n,{alpha}) reactions in aluminium and nickel at 14.77 MeV neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Lalremruata, B.; Dhole, S.D. [Department of Physics, University of Pune, Pune-411007 (India); Ganesan, S. [Reactor Physics Design Division, BARC, Mumbai-400085 (India); Bhoraskar, V.N. [Department of Physics, University of Pune, Pune-411007 (India)], E-mail: vnb@physics.unipune.ernet.in

    2009-04-15

    The double differential cross-sections (DDX) for the emission of alpha particles from {sup 27}Al(n,{alpha}){sup 24}Na and Ni(n,{alpha}) reactions induced by 14.77 MeV neutrons were estimated from the alpha particle spectra recorded at 30 deg., 50 deg., 90 deg., 110 deg. angles for aluminium, and at 20 deg., 45 deg., 90 deg., 110 deg. for natural nickel. The results indicate that the alpha particles below and around the most probable energies ({approx}6.3 MeV from aluminium and {approx}8 MeV from natural nickel) are emitted predominantly through the compound nucleus formation process, and the higher energy alpha particles are emitted through the pre-equilibrium or the direct reaction. In general, the measured double-differential cross-sections are in agreement with the theoretical cross-sections estimated using Talys-1.0 and Preco2007 computer programs. The present value of the level density parameter for {sup 24}Na is close to the literature value and, therefore, these results reveal consistency in the alpha particle spectra recorded with a single silicon surface barrier detector at different scattering angles.

  20. Monte-Carlo Simulation of γ-ray and Fast Neutron Radiolysis of Liquid Water and 0.4 M H2SO4 Solutions at Temperatures up to 325 oC

    International Nuclear Information System (INIS)

    Sunaryo, G.R.; Jintana, M.; Gerin, J.P.J.

    2011-01-01

    Monte-Carlo simulations were used to study the radiolysis of liquid water at 25-325 o C when subjected to low linear energy transfer (LET) of 60 Co γ-ray radiation and fast neutrons of 2 and 0.8 MeV. The energy deposited in the early stage of 60 Co γ--ray irradiation was approximated by considering short segments (∼150 μm) of 300 MeV proton tracks, corresponding to an average LET of ∼0.3 keV/μm. In case of 2 MeV fast neutrons, the energy deposited was considered by using short segments (∼5 μm) of energy at 1.264, 0.465, 0.171, 0.063 and 0.24 MeV. 0.8 MeV fast neutrons were approximated by 0.505, 0.186, 0.069 and 0.025 MeV protons. The effect of 0.4 M H 2 SO 4 solution on radiolysis was also studied by this method for both 60 Co γ-rays and 0.8 MeV fast neutrons. The simulated results at the time of 10 -7 s after irradiation were obtained and compared with the available experimental results published by other researchers to be in excellent agreement with them over the entire temperature ranges and radiation sources studied. Except for g(H 2 ) that increase with temperature rises, the general behaviors of higher radical products and lower molecular products at higher temperatures were obtained. The LET effect is also validated by this study, showing that the increase in LET would yield higher molecular and lower radical products. Studies on 0.4 M H 2 SO 4 solutions also show good agreement between the computed and experimental data for γ-ray irradiation: the presence of 0.4 M H + , except for g(H 2 ) that gives lower value at 25 o C and higher value at 325 o C, gives the higher values for radicals and g(H 2 O 2 ) at 25 o C and lower values at 325 o C, compared with that for neutral water. The computed data show good agreement with the experimental data for 0.4 M H 2 SO 4 solutions induced by 0.8 MeV fast neutrons, except for g(H 2 ) and g(H · ) that gives good agreement up to 50 o C, then the opposite tendencies with the further temperature rises

  1. Performance test of ex-core high temperature and high pressure water loop test equipment (Contract research)

    International Nuclear Information System (INIS)

    Nakano, Hiroko; Uehara, Toshiaki; Takeuchi, Tomoaki; Shibata, Hiroshi; Nakamura, Jinichi; Matsui, Yoshinori; Tsuchiya, Kunihiko

    2016-03-01

    In Japan Atomic Energy Agency, we started research and development so as to monitor the situations in the Nuclear Plant Facilities during a severe accident, such as a radiation-resistant monitoring camera, a radiation-resistant transmission system for conveying the in-core information, and a heat-resistant signal cable. As a part of developments of the heat-resistant signal cable, we prepared ex-core high-temperature and high-pressure water loop test equipment, which can simulate the conditions of BWRs and PWRs, for evaluating reliability and properties of sheath materials of the cable. This equipment consists of autoclave, water conditioning tank, high-pressure metering pump, preheater, heat exchanger and water purification equipment, etc. This report describes the basic design and the performance test results of ex-core high-temperature and high-pressure water loop test equipment. (author)

  2. Construction of a pulsed MeV positron beam line

    Energy Technology Data Exchange (ETDEWEB)

    Masuno, Shin-ichi; Okada, Sohei; Kawasuso, Atsuo [Japan Atomic Energy Research Inst., Takasaki, Gunma (Japan). Takasaki Radiation Chemistry Research Establishment

    1997-03-01

    To develop a fast (1 MeV) and short pulsed (100 ps) positron beam which enables defect behavior analysis of bulk states of materials even at high temperatures where a usual positron source would melt, we have been performing design study and construction of the beam line in a three-year program since 1994. This report describes the components, design study results and experimental results of the completed parts until now. (author)

  3. Development of polystyrene calorimeter for application at electron energies down to 1.5 MeV

    DEFF Research Database (Denmark)

    Miller, A.; Kovacs, A.; Kuntz, F.

    2002-01-01

    Polystyrene (PS) calorimeters developed at Riso National Laboratory for use below 4 MeV have been modified due to irradiation technology requirements concerning both design principles and dimensions. The temperature-time relationship after irradiation was measured, and two ways of dose measurement...... the average and the surface dose and to prove the applicability of the new low energy calorimeter for calibration purposes at 1.5 and 2 MeV electron energy. Alanine dosimeters of 2 mm thickness were used to calibrate the calorimeters and their use for nominal dose measurements was demonstrated in a series...... of intercomparisons. The use as routine dosimeters at electron accelerators operating in the energy range of 1.5-4 MeV was also demonstrated. (C) 2002 Elsevier Science Ltd. All rights reserved....

  4. Interactions of 100 MeV/nucleon 40Ar with uranium

    International Nuclear Information System (INIS)

    Frankel, K.A.

    1979-01-01

    Fragments produced in the interactions of 100 MeV/nucleon 40 Ar projectiles with a uranium target have been measured at energies from 10 to 130 MeV/nucleon at angles from 10 0 to 170 0 . Nuclei with charge 5 less than or equal to Z less than or equal to 10 were observed. The data can roughly be divided into two groups, corresponding to central and peripheral collisions. The central collision data can be fit with a thermal model that uses two recoiling sources. The source velocities are consistent with the predictions of the fireball and target explosion models, but the source temperatures inferred from the data are higher than one would expect on the basis of energy and momentum conservation. These results are similar to those obtained in previous studies at beam energies of 400 and 500 MeV/nucleon. The data also follow the pattern of the universal curve of invariant cross section vs momentum observed at higher beam energies by Price et al. The projectile fragmentation data are also fit by two thermal sources. There are indications that the observed temperatures are higher than one would expect on the basis of other projectile fragmentation studies. The projectile fragmentation data are studied in terms of a simple friction model. Order of magnitude estimates show that the data may be consistent with the model, but further development, calculation and experimentation are necessary to check the validity of the model at this beam energy. A preliminary investigation is made of the possibility that the projectile may pick up one or more target nucleons before it fragments. This process leads to widening of the distributions at large momentum transfers. From this broad survey we find that much of the spectrum can be described by falling exponentials in energy in the emitting frames. We conclude that the observed spectrum is due to nonthermal sources as the temperatures derived from the slopes of the exponentials are greater than those we predict

  5. A dispersive optical model for n + {sup 120}Sn from -15 to +80 MeV and properties of neutron single-particle and single-hole states

    Energy Technology Data Exchange (ETDEWEB)

    Chen Zemin [Department of Physics, Duke University and Triangle Universities Nuclear Laboratory, Durham, NC 27708-0308 (United States); Walter, R L [Department of Physics, Duke University and Triangle Universities Nuclear Laboratory, Durham, NC 27708-0308 (United States); Tornow, W [Department of Physics, Duke University and Triangle Universities Nuclear Laboratory, Durham, NC 27708-0308 (United States); Weisel, G J [Department of Physics, Duke University and Triangle Universities Nuclear Laboratory, Durham, NC 27708-0308 (United States); Howell, C R [Department of Physics, Duke University and Triangle Universities Nuclear Laboratory, Durham, NC 27708-0308 (United States)

    2004-12-01

    Data for {sigma}({theta}) and A{sub y}({theta}) previously obtained at the Triangle Universities Nuclear Laboratory for {sup 120}Sn(n, n) are combined with other measurements of {sigma}({theta}) and A{sub y}({theta}) to create an elastic-scattering database from 9.9 to 24 MeV. In addition, relatively recent high-accuracy measurements of the neutron total cross section {sigma}{sub T} for Sn from 5 to 80 MeV are combined with earlier {sigma}{sub T} data to form a detailed {sigma}{sub T} database from 0.24 to 80 MeV. All of these data are analysed in the framework of a dispersive optical model (DOM). The DOM is extended to negative energies to investigate properties of single-particle and single-hole bound states. The DOM also is used in calculations of compound-nucleus contributions to {sigma}({theta}), so that DOM predictions can be compared to {sigma}({theta}) measurements. Excellent agreement is obtained for the entire set of scattering data from 0.4 to 24 MeV, and for {sigma}{sub T} values from 0.05 to 80 MeV. Calculations of bound-state quantities are compared to values derived from experiment for energies down to -15 MeV. Reasonable agreement for the binding energies is achieved, while the predicted spectroscopic factors disagree somewhat with the values found in stripping and pickup experiments. Finally, the DOM is modified to investigate two features (volume absorption that is asymmetric about the Fermi energy and zero absorption in the vicinity of the Fermi energy) that have been ignored in many DOM models. These modifications have little effect on the agreement of the calculations with the scattering data or with the bound-state quantities.

  6. OXIDATIVE ALKYLATION OF (ETA-5-C5ME5)2TIR (R=CL, ME, ET, CH=CH2, PH, OME, N=C(H)TERT-BU) TO (ETA-5-C5ME5)2TI(ME)R BY GROUP-12 ORGANOMETALLIC COMPOUNDS MME2

    NARCIS (Netherlands)

    LUINSTRA, GA; TEUBEN, JH

    1991-01-01

    Oxidative alkylation of Cp*2TiX (Cp*: eta-5-C5Me5; X = OMe, Cl, N = C(H)tBu) and Cp*2TiMe by CdMe2 or ZnMe2 gives diamagnetic Cp*2Ti(Me)X and Cp*2TiMe2 respectively, and cadmium or zinc. The reactions of Cp*2TiR (R = Et, CH = CH2, Ph) with MMe2 (M = Cd, Zn) give statistical mixtures of Cp*2Ti(Me)R,

  7. The behavior of plastic deformation in a duplex Cu-Zn alloy, in the temperature range 24-3000C

    International Nuclear Information System (INIS)

    Andrade, A.H.P. de.

    1978-01-01

    The mechanical behavior of Muntz Metal (Cu-40%Zn) containing duplex microstructure with a coarse grain size approximately 40μm) has been investigated at the temperature range 2 0 -300 0 C, and at strain rat e of epsilon=2.6x10 -4 S -1 , as a function of the second phase volume fraction(v(subβ)). Whereas at room temperature yielding increases with v(subβ) for v(subβ)>0.35, it remains virtually independent of v(subβ in the range 0.26 0 C. At low temperature (RT) and strains (epsilon approximately 0.01 the work hardening rate increases strongly with v subβ up to v subβ approximately 0.45. At higher temperatures and strains work hardening rate decreases for all volume fractions due to the thermal and dynamic recovery respectively. Then ultimate tensile strength (UTS) at room temperature increases with v subβ up to v subβ = 0.45, thus resulting in overall increase in U.T.S. The Portevin - Le Chatelier Effect (PLE)in Muntz Metal, at the temperature range 24 0 -300 0 C manifests itself in essentially two different forms. At RT, irregular serrations are observed, where amplitude decreases with increases in v subβ. At higher temperatures (100 0 C), serrations become regular, with increase in amplitude. At 200 0 C or over the serrations amplitude decrease at almost disappearing completely. These observations have been explained on the basis of collective behavior of mobile dislocations, influenced by the internal stress fields created during deformation by the presence of phase β. The Voce equation fits well with the experimental stress-strain data for temperatures up to 200 0 C. The method of Hollomon requires the use of stages in sigma-epsilon curve, curve, which does not have a physical significance. (Author) [pt

  8. KOMPOSISI KIMIA DAN KRISTALINITAS TEPUNG PISANG TERMODIFIKASI SECARA FERMENTASI SPONTAN DAN SIKLUS PEMANASAN BERTEKANAN-PENDINGINAN (Chemical Composition and Crystallinity of Modified Banana Flour by Spontaneous Fermentation and Autoclaving-Cooling Cycle

    Directory of Open Access Journals (Sweden)

    Nurhayati Nurhayati

    2014-07-01

    (39,13 – 42,68% bk dibandingkan dengan yang satu siklus (29,34 – 35,93% bk. Proses pemanasan bertekananpendinginan menurunkan kristalinitas tepung pisang dari 18,74-20,08% menjadi 6,98-9,52%. Difraksi sinar X menunjukkan granula pati pisang adalah granula tipe C yang merupakan campuran dari granula tipe A dan tipe B. Kata kunci: Tepung pisang termodifikasi, fermentasi spontan, autoclaving-cooling cycles

  9. Alcohol synthesis in a high-temperature slurry reactor

    Energy Technology Data Exchange (ETDEWEB)

    Roberts, G.W.; Marquez, M.A.; McCutchen, M.S. [North Carolina State Univ., Raleigh, NC (United States)

    1995-12-31

    The overall objective of this contract is to develop improved process and catalyst technology for producing higher alcohols from synthesis gas or its derivatives. Recent research has been focused on developing a slurry reactor that can operate at temperatures up to about 400{degrees}C and on evaluating the so-called {open_quotes}high pressure{close_quotes} methanol synthesis catalyst using this reactor. A laboratory stirred autoclave reactor has been developed that is capable of operating at temperatures up to 400{degrees}C and pressures of at least 170 atm. The overhead system on the reactor is designed so that the temperature of the gas leaving the system can be closely controlled. An external liquid-level detector is installed on the gas/liquid separator and a pump is used to return condensed slurry liquid from the separator to the reactor. In order to ensure that gas/liquid mass transfer does not influence the observed reaction rate, it was necessary to feed the synthesis gas below the level of the agitator. The performance of a commercial {open_quotes}high pressure {close_quotes} methanol synthesis catalyst, the so-called {open_quotes}zinc chromite{close_quotes} catalyst, has been characterized over a range of temperature from 275 to 400{degrees}C, a range of pressure from 70 to 170 atm., a range of H{sub 2}/CO ratios from 0.5 to 2.0 and a range of space velocities from 2500 to 10,000 sL/kg.(catalyst),hr. Towards the lower end of the temperature range, methanol was the only significant product.

  10. The reaction of TcCl3(Me2PhP)3 with dithio ligands. Synthesis, characterization and X-ray crystal structures of [TcCl2(Me2PhP)2(Me2dtp)]and [Tc(Me2PhP)(Etxan)3](Me2PhP=dimethylphenylphosphine, Me2dtp-=O,O'-dimethyldithiophosphate, Etxan-=ethylxanthate)

    International Nuclear Information System (INIS)

    Lorenz, B.; Schmidt, K.; Hiller, W.; Abram, U.; Huebener, R.

    1993-01-01

    Trichlorotris (dimethylphenylphosphine)technetium(III); [TcCl 3 (Me 2 PhP) 3 ], reacts with dithio ligands to form chelate complexes of different compositions and coordinations geometries. The reaction with ethylxanthate (Etxan - ) yields the diamagnetic seven-coordinate [Tc(Me 2 PhP)(Etxan) 3 ], which crystallizes monoclinic in the space group P2 2 /c with Z = 4 (a = 18.44(5), b = 9.2(1), c = 15.36(6) A, β = 104.3(2) ). The final R value is 0.029. The metal has a pentagonal-bipyramidal environment. With ammonium dimethyldithiophosphate, (NH 4 )Me 2 dtp, [TcCl 3 (Me 2 PhP) 3 ] forms the paramagnetic [TcCl 2 (Me 2 PhP) 2 (Me 2 dtp) in which the technetium atom has a distorted octahedral coordination sphere. The compound crystallizes orthorhombic, space group Pbcn, with Z = 4 (a = 16.20(1), b = 10.445(1), c 14.878(1)). The final R value is 0.031. The chloro ligands are in trans arrangement. (orig.)

  11. Analysis of the proton-induced reactions at 150 MeV - 24 GeV by high energy nuclear reaction code JAM

    International Nuclear Information System (INIS)

    Niita, Koji; Nara, Yasushi; Takada, Hiroshi; Nakashima, Hiroshi; Chiba, Satoshi; Ikeda, Yujiro

    1999-09-01

    We are developing a nucleon-meson transport code NMTC/JAM, which is an upgraded version of NMTC/JAERI. NMTC/JAM implements the high energy nuclear reaction code JAM for the infra-nuclear cascade part. By using JAM, the upper limits of the incident energies in NMTC/JAERI, 3.5 GeV for nucleons and 2.5 GeV for mesons, are increased drastically up to several hundreds GeV. We have modified the original JAM code in order to estimate the residual nucleus and its excitation energy for nucleon or pion induced reactions by assuming a simple model for target nucleus. As a result, we have succeeded in lowering the applicable energies of JAM down to about 150 MeV. In this report, we describe the main components of JAM code, which should be implemented in NMTC/JAM, and compare the results calculated by JAM code with the experimental data and with those by LAHET2.7 code for proton induced reactions from 150 MeV to several 10 GeV. It has been found that the results of JAM can reproduce quite well the experimental double differential cross sections of neutrons and pions emitted from the proton induced reactions from 150 MeV to several 10 GeV. On the other hand, the results of LAHET2.7 show the strange behavior of the angular distribution of nucleons and pions from the reactions above 4 GeV. (author)

  12. Chemical, temperature, and other data from bottle casts in a world-wide distribution from 04 October 1961 to 24 August 1990 (NODC Accession 0000231)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Chemical, temperature, and other data were collected using bottle casts in a world-wide distribution from multiple ships from October 4, 1961 to August 24, 1990....

  13. Charging kinetics in virgin and 1 MeV-electron irradiated yttria-stabilized zirconia in the 300-1000 K range

    International Nuclear Information System (INIS)

    Thome, T.; Braga, D.; Blaise, G.; Cousty, J.; Pham Van, L.; Costantini, J.M.

    2006-01-01

    A study performed with a dedicated scanning electron microscope (SEM) on the surface electrical properties of (1 0 0)-oriented yttria-stabilized zirconia (YSZ) single crystals irradiated with 1 MeV electrons is presented. When compared with virgin YSZ, the 1 MeV-irradiated YSZ shows a decrease of the intrinsic total electron emission coefficient σ 0 and an increase of the time constant τ associated with the charging kinetics of the material at room temperature. These measurements performed with the SEM beam at 10 keV indicate that the defects induced by the 1 MeV-electron irradiation generate a positive electric field of the order of 0.5 x 10 6 V/m at a depth of about 1 μm that prevents electrons to escape. When the SEM beam with a 1.1 keV energy is used, a smaller field (∼0.5 x 10 3 V/m) is detected closer to the surface (∼20 nm). The fading of these fields during the thermal annealing in the 400-1000 K temperature range provides information on the nature of defects induced by the 1 MeV-electron irradiation

  14. Activity of bimetallic catalysts (Pt + Me)/A12030 in butane hydrogenolysis and benzene hydrogenation

    International Nuclear Information System (INIS)

    Zharkov, B.B.; Rubinov, A.Z.

    1986-01-01

    The authors evaluate the decomposing and hydrogenating activity of some Me/Al 2 0 3 0 and (Pt + Me)/Al 203 catalysis for the reactions of butane hydrogenolysis and conversion of benzene to cyclohexane. The temperature was 180-300 C for butane transformation and 150 C for benzene hydrogenation. During both reactions some initial decrease of catalytic activity which stabilized over 2-3 h was observed. The results show that roasting Re-containing reforming catalysts at fairly high temperatures (500-550 C) balances maximum hydrogenating and average splitting activities, thus guaranteeing high resistance to coke deposition while preserving the necessary selectivity. The decreased hydrogenating capacity of Ir/A1 2 0 3 0 and (Pt + Ir)/A1 23 0 catalysts after roasting at 500 C indicates insufficient thermal stability, which can be why renewing the initial activity of iridium containing forming catalysts by oxidating regeneration is difficult

  15. Give Me Strength.

    Institute of Scientific and Technical Information of China (English)

    维拉

    1996-01-01

    Mort had an absolutely terrible day at the office.Everythingthat could go wrong did go wrong.As he walked home he could beheard muttering strange words to himself:“Oh,give me strength,give me strength.”Mort isn’t asking for the kind of strength thatbuilds strong muscles:he’s asking for the courage or ability to

  16. Extension of thermophysical and thermodynamic property measurements by laser pulse heating up to 10,000 K. I. Under pressure

    Science.gov (United States)

    Ohse, R. W.

    1990-07-01

    The necessity for increased high-temperature data reliability and extension of thermophysical property measurements up to 5000 K and above are discussed. A new transient-type laser-autoclave technique (LAT) has been developed to extend density and heat capacity measurements of high-temperature multicomponent systems far beyond their melting and boiling points. Pulsed multibeam laser heating is performed in an autoclave under high inert gas pressure to eliminate evaporation. The spherical samples are positioned by containment-free acoustic levitation regardless of their conductive or magnetic properties. Temperature, spectral and total emittances are determined by a new microsecond six-wavelength pyrometer coupled to a fast digital data acquisition system. The density is determined by high resolution microfocus X-ray shadow technique. The heat capacity is obtained from the cooling rate. Further applications are a combination of the laser-autoclave with splat cooling techniques for metastable structure synthesis and amorphous metals research and an extension of the LAT for the study of critical phenomena and the measurement of critical-point temperatures.

  17. The design and construction of a scintillation pair spectrometer for the detection of {gamma}-rays in the energy range 2-20 MeV; Realisation d'un spectrometre a scintillations et a paires pour la detection des rayonnements {gamma} d'energie comprise entre 2 et 20 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Longequeue, J P [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1958-07-15

    The scintillation pair spectrometer is designed to allow the measurement of the energy of {gamma} rays in the range 2 to 20 MeV. Such an instrument is chosen because of its main features: high energy resolution and ease of working. Against this, however, the efficiency is low. It was possible to tolerate this low efficiency because of the facts that the {gamma}-rays studied emanated from (p, {gamma}) reactions and that the two electrostatic acceleration available could provide beams of 500 {mu}A having energy maxima at 300 and 600 keV. We used the {gamma} rays produced by the reactions {sup 23}Na (p, {gamma}) {sup 24}Mg, {sup 19}F (p, {alpha} {gamma}) {sup 16}O and {sup 7}Li (p, {gamma}) {sup 8}Be as well as the {gamma} rays emitted by sources of RTh and of {sup 24}Na. Under these conditions the spectrometer attained a resolving power of 6,5 {+-} 0,5 per cent at 6,1 MeV and it was able to separate the 14,8 and 17,6 MeV lines produced by the reaction {sup 7}Li (p, {gamma}) {sup 8}Be. As well as this, the efficiency which varied from 2.10{sup -4} to 1,7.10{sup -3} between 2 and 20 MeV was well above the efficiencies already obtained with this type of instrument. (author) [French] Le spectrometre a scintillations et a paires presente dans cette these a pour but de mesurer l'energie des rayonnements {gamma} dans la bande de 2 a 20 MeV. Le choix d'un tel appareil est du a ses caracteristiques essentielles: bonne resolution en energie et maniabilite. Par contre, son efficacite est faible. Nous avons pu tolerer cette faible efficacite car les rayonnements {gamma} que nous avons etudies provenaient de reactions (p, {gamma}) et les deux accelerateurs electrostatiques dont nous disposions pouvaient fournir des faisceaux de 500 {mu}A avec des energies maximum de 300 et 600 keV. Nous avons utilise les rayonnements {gamma} produits par les reactions {sup 23}Na (p, {gamma}) {sup 24}Mg, {sup 19}F (p, {alpha} {gamma}) {sup 16}O et {sup 7}Li (p, {gamma}) {sup 8}Be ainsi que les

  18. Obtaining zeolites from slags and ashes from a waste combustion plant in an autoclave process

    Directory of Open Access Journals (Sweden)

    Grela Agnieszka

    2017-01-01

    Full Text Available Waste combustion is associated with the generation of post-processing solid products – waste such as slag and ash. One of the promising technologies in waste management and processing is the synthesis of zeolites and other materials exhibiting sorption properties. The aim of this study was to characterise and assess the physicochemical properties of the waste and the products synthesised from it. This paper presents the possibility of synthesis zeolites from the slag and ash from two waste combustion plants. The investigated waste is classified as hazardous waste and denoted by the EWC code 190111*. The paper presents the results of physicochemical studies of these materials. As a result of synthesis in an autoclave at 140°C with the use of 2 M NaOH, and other compounds, such zeolite forms as chabazite and sodalite were obtained. Textural studies and ion-exchange capacity investigations carried out allowed characterisation of the sorption properties of the materials. It was found that the materials obtained are characterised by the BET specific surface areas of 25.45 m2/g and 16.79 m2/g.

  19. Autoclave treatment of pig manure does not reduce the risk of transmission and transfer of tetracycline resistance genes in soil: successive determinations with soil column experiments.

    Science.gov (United States)

    Kang, Yijun; Gu, Xian; Hao, Yangyang; Hu, Jian

    2016-03-01

    The increasing use of antibiotics, especially tetracycline, in livestock feed adversely affects animal health and ecological integrity. Therefore, approaches to decrease this risk are urgently needed. High temperatures facilitate antibiotic degradation; whether this reduces transmission risk and transfer of tetracycline-resistant bacteria (TRBs) and tetracycline resistance genes (TRGs) in soil remains unknown. Successive experiments with soil columns evaluated the effects of autoclaving pig manure (APM) on soil TRB populations and TRGs over time at different soil depths. The data showed sharp increases in TRB populations and TRGs in each subsoil layer of PM (non-APM) and APM treatments within 30 days, indicating that TRBs and TRGs transferred rapidly. The level of TRBs in the upper soil layers was approximately 15-fold higher than in subsoils. TRBs were not dependent on PM and APM levels, especially in the late phase. Nevertheless, higher levels of APM led to rapid expansion of TRBs as compared to PM. Moreover, temporal changes in TRB frequencies in total culturable bacteria (TCBs) were similar to TRBs, indicating that the impact of PM or APM on TRBs was more obvious than for TCBs. TRBs were hypothesized to depend on the numbers of TRGs and indigenous recipient bacteria. In the plough layer, five TRGs (tetB, tetG, tetM, tetW, and tetB/P) existed in each treatment within 150 days. Selective pressure of TC may not be a necessary condition for the transfer and persistence of TRGs in soil. High temperatures might reduce TRBs in PM, which had minimal impact on the transmission and transfer of TRGs in soil. Identifying alternatives to decrease TRG transmission remains a major challenge.

  20. Safety characteristics of hydrogen at super ambient conditions: lubricant contamination influencing the auto ignition temperature

    International Nuclear Information System (INIS)

    Liebner, C.; Schroder, V.; Holtappels, K.

    2006-01-01

    Inventing hydrogen as a commonly used future energy carrier the long term social acceptance as well as the clean energy image strongly depends upon the safety of its applications. The safety characteristics of hydrogen build a special challenge e.g. in the field of combustion engine development. Small impurities from lubricants used in motors and pumps, may serve as radical source, strongly influencing the auto ignition temperature of hydrogen. Auto Ignition Temperature (AIT) of Hydrogen-Air mixtures were measured in closed autoclaves made from stainless steel, similar to the closed bomb method described in the European standard EN 1839. Initial pressures of 10 bar(a) and 30 bar(a) of a premixed stoichiometric hydrogen-air mixture were investigated. Auto ignition can be obtained about 100 K below the standard AIT (560 deg C, atmospheric pressure) and 300 K below the standard AIT when contaminated through motor oil. (authors)

  1. Proton continuum spectra from deuteron break-up at 56 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Matsuoka, N.; Kondo, M.; Shimizu, A.; Saito, T.; Nagamachi, S. [Osaka Univ., Suita (Japan). Research Center for Nuclear Physics; Sakaguchi, H.; Ohtani, F.; Goto, A.; Ikegami, H.; Muraoka, M [eds.

    1980-01-01

    Proton continuum spectra from deuteron break-up have been measured for 14 elements at 56 MeV. Each spectrum shows a prominent bump at forward angles. Projectile break-up calculations reproduce well the spectral shapes and the angular dependence of the bump spectra. The break-up cross section is nearly proportional to (A sup(1/3) + 0.8)/sup 2/. The total break-up cross section amounts to 24 - 35% of the deuteron total reaction cross section.

  2. JST Thesaurus Headwords and Synonyms: 水ゾル [MeCab user dictionary for science technology term[Archive

    Lifescience Database Archive (English)

    Full Text Available MeCab user dictionary for science technology term 水ゾル 名詞 一般 * * * * ヒドロゾル ヒドロゾル ヒドロゾル Thesaurus2015 200906059522009173 V CA24 UNKNOWN_2 水 ゾル

  3. Flow behaviour of autoclaved, 20% cold worked, Zr-2.5Nb alloy pressure tube material in the temperature range of room temperature to 800 deg. C

    International Nuclear Information System (INIS)

    Dureja, A.K.; Sinha, S.K.; Srivastava, Ankit; Sinha, R.K.; Chakravartty, J.K.; Seshu, P.; Pawaskar, D.N.

    2011-01-01

    Pressure tube material of Indian Heavy Water Reactors is 20% cold-worked and stress relieved Zr-2.5Nb alloy. Inherent variability in the process parameters during the fabrication stages of pressure tube and also along the length of component have their effect on micro-structural and texture properties of the material, which in turn affect its strength parameters (yield strength and ultimate tensile strength) and flow characteristics. Data of tensile tests carried out in the temperature range from room temperature to 800 deg. C using the samples taken out from a single pressure tube have been used to develop correlations for characterizing the strength parameters' variation as a function of axial location along length of the tube and the test temperature. Applicability of Ramberg-Osgood, Holloman and Voce's correlations for defining the post yield behaviour of the material has been investigated. Effect of strain rate change on the deformation behaviour has also been studied.

  4. Pre-analytical variables of circulating cell-free nucleosomes containing 5-methylcytosine DNA or histone modification H3K9Me3

    DEFF Research Database (Denmark)

    Rasmussen, Louise; Herzog, Marielle; Rømer, Eva

    2016-01-01

    Aim: To evaluate pre-analytical variables of circulating cell-free nucleosomes containing 5-methylcytosine DNA (5mC) or histone modification H3K9Me3 (H3K9Me3). Materials and methods: Six studies were designed to assess the possible influence of pre-analytical variables. Study 1: influence of stasis...... significantly lower levels of 5mC or H3K9Me3 compared to levels in healthy individuals. Conclusion: Levels of 5mC or H3K9Me3 appear stable in most pre-analytical settings if blood samples are stored at room temperature until centrifugation....

  5. Evolution of the reaction 40Ar + Ag from E/A = 7 to 34 MeV

    International Nuclear Information System (INIS)

    Alexander, J.M.

    1991-01-01

    The 4π charged-particle multidetector AMPHORA has been used to study the reaction 40 Ar + nat Ag from 270 - 1,356 MeV. Charged-particle multiplicity distributions show a low-multiplicity group associated with peripheral collisions and a high multiplicity group associated with central collisions. Average multiplicities for central collisions increase with increasing projectile energy, indicating ever-increasing collision violence. Angular distributions of emitted protons are essentially isotorpic for θ ≥ 80 degree in a reference frame characterized by the empirical systematics of linear momentum transfer (i.e. ∼ 100% to ∼ 70% from 7-34 MeV/nucleon). Spectra of these protons at side angles are evaporation-like in shape and indicate relative effective temperatures of 3, 6, 8, and 12 MeV for beam energies of 7, 17, 27 and 34 MeV respectively. Azimuthal angular correlations between various pairs are consistent with spin-driven emission from emitter sources of reasonable spin values. In short, these results support a classical picture of extensively thermalized emitter nuclei even for initial excitation energies of ∼ 5 MeV per system nucleon and spins of ≥ 100ℎ

  6. Ion-beam synthesis and photoluminescence of SiC nanocrystals assisted by MeV-heavy-ion-beam annealing

    International Nuclear Information System (INIS)

    Khamsuwan, J.; Intarasiri, S.; Kirkby, K.; Chu, P.K.; Singkarat, S.; Yu, L.D.

    2012-01-01

    This work explored a novel way to synthesize silicon carbide (SiC) nanocrystals for photoluminescence. Carbon ions at 90 keV were implanted in single crystalline silicon wafers at elevated temperature, followed by irradiation using xenon ion beams at an energy of 4 MeV with two low fluences of 5 × 10 13 and 1 × 10 14 ions/cm 2 at elevated temperatures for annealing. X-ray diffraction, Raman scattering, infrared spectroscopy and transmission electron microscopy were used to characterize the formation of nanocrystalline SiC. Photoluminescence was measured from the samples. The results demonstrated that MeV-heavy-ion-beam annealing could indeed induce crystallization of SiC nanocrystals and enhance emission of photoluminescence with violet bands dominance due to the quantum confinement effect.

  7. Reaction of ether and thioether functionalised 1-alkenes with the cationic permethylzirconocene olefin polymerisation catalyst [(eta(5)-C5Me5)(2)ZrMe](+). Molecular structure of the insertion product [(eta(5)-C5Me5)(2)ZrCH2CH(Me)CH2OEt](+)

    NARCIS (Netherlands)

    Bijpost, Erik A; Zuideveld, Martin A.; Meetsma, Auke; Teuben, Jan H

    1998-01-01

    Reaction of [(η5-C5Me5)2ZrMe][MeB(C6F5)3] (1) with (thio)ether functionalised alkenes: 3-ethoxy-1-propene and 3-(methylthio)-1-propene gives stable insertion products [(η5-C5Me5)2ZrCH2CH(Me)CH2XR][MeB(C6F5)3] (2: X = O, R = Et; 3: X = S, R = Me) in which the (thio)ether function is intramolecularly

  8. Mean lives of the 5.106 and 5.834 MeV levels of 14N

    International Nuclear Information System (INIS)

    Bhalla, R.K.; Poletti, A.R.

    1982-01-01

    The recoil distance method (RDM) has been used to measure the mean lives of the 5.106 and 5.834 MeV levels of 14 N as tau = 6.27 +- 0.10 ps and tau = 11.88 +- 0.24 ps respectively. The results are compared to previous measurements and to shell-model calculations. (orig.)

  9. Separation of reaction mechanisms at low energy. Study of the reactions: {sup 27}Al(d,p) {sup 28}Al, {sup 24}Mg(d,p) {sup 25}Mg, and {sup 24}Mg(d, {alpha}) {sup 22}Na; Sur la separation des mecanismes de reaction a basse energie. Etude des reactions: {sup 27}Al(d,p) {sup 28}Al, {sup 24}Mg(d,p) {sup 25}Mg, et {sup 24}Mg(d, {alpha}) {sup 22}Na

    Energy Technology Data Exchange (ETDEWEB)

    Mermaz, M. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1966-06-01

    The two sets of angular distributions of (d,p) reactions on Al and Mg, measured between 2 and 6 MeV, have given the possibility to test, in analysing the statistical fluctuations of cross-section, the validity of the separation of their mean values in two parts, one 'direct', another given by the statistical mechanism. With the same method of analysis we have studied excitation functions for several alpha groups of the reaction {sup 24}Mg(d, {alpha}) {sup 22}Na and given an evidence for an intermediate structure for the alpha channel leading to the 3. excited state of {sup 22}Na. The angular distribution of the wide resonance at 15.9 MeV in {sup 26}Al has been obtained. (author) [French] Les deux ensembles de distributions angulaires des reactions (d,p) sur Al et Mg, mesures entre 2 et 6 MeV, nous ont permis, en analysant les fluctuations statistiques de sections efficaces, de verifier la possibilite de la separation de leurs valeurs moyennes en deux composantes: l'une 'directe', l'autre due au mecanisme statistique. Avec la meme methode d'analyse nous avons etudie les fonctions d'excitation des premiers groupes alpha de la reaction {sup 24}Mg(d,{alpha}) {sup 22}Na et mis en evidence une structure intermediaire pour la voie de reaction aboutissant au 3eme niveau de {sup 22}Na. Nous avons obtenu la distribution angulaire de la resonance large situee a une energie d'excitation de 15,9 MeV dans {sup 26}Al. (auteur)

  10. Separation of reaction mechanisms at low energy. Study of the reactions: {sup 27}Al(d,p) {sup 28}Al, {sup 24}Mg(d,p) {sup 25}Mg, and {sup 24}Mg(d, {alpha}) {sup 22}Na; Sur la separation des mecanismes de reaction a basse energie. Etude des reactions: {sup 27}Al(d,p) {sup 28}Al, {sup 24}Mg(d,p) {sup 25}Mg, et {sup 24}Mg(d, {alpha}) {sup 22}Na

    Energy Technology Data Exchange (ETDEWEB)

    Mermaz, M [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1966-06-01

    The two sets of angular distributions of (d,p) reactions on Al and Mg, measured between 2 and 6 MeV, have given the possibility to test, in analysing the statistical fluctuations of cross-section, the validity of the separation of their mean values in two parts, one 'direct', another given by the statistical mechanism. With the same method of analysis we have studied excitation functions for several alpha groups of the reaction {sup 24}Mg(d, {alpha}) {sup 22}Na and given an evidence for an intermediate structure for the alpha channel leading to the 3. excited state of {sup 22}Na. The angular distribution of the wide resonance at 15.9 MeV in {sup 26}Al has been obtained. (author) [French] Les deux ensembles de distributions angulaires des reactions (d,p) sur Al et Mg, mesures entre 2 et 6 MeV, nous ont permis, en analysant les fluctuations statistiques de sections efficaces, de verifier la possibilite de la separation de leurs valeurs moyennes en deux composantes: l'une 'directe', l'autre due au mecanisme statistique. Avec la meme methode d'analyse nous avons etudie les fonctions d'excitation des premiers groupes alpha de la reaction {sup 24}Mg(d,{alpha}) {sup 22}Na et mis en evidence une structure intermediaire pour la voie de reaction aboutissant au 3eme niveau de {sup 22}Na. Nous avons obtenu la distribution angulaire de la resonance large situee a une energie d'excitation de 15,9 MeV dans {sup 26}Al. (auteur)

  11. A Low Temperature Synthetic Route to Nanocrystalline TiN

    African Journals Online (AJOL)

    NICO

    This method may be extended to the synthesis of other metal nitrides. ... direct current magnetron sputtering17, and mechanical mill- ... recent years, autoclaved synthesis of TiN nanomaterials from ... 3.2 XPS Characterization of the Samples.

  12. Frictional characteristics of silicon graphite lubricated with water at high pressure and high temperature

    International Nuclear Information System (INIS)

    Lee, Jae Seon; Kim, Eun Hyun; Park, Jin Seok; Kim, Jong In

    2001-01-01

    Experimental frictional and wear characteristics of silicon graphite materials is studied in this paper. Those specimens are lubricated with high temperature and highly pressurized water to simulate the same operating condition for the journal bearing and the thrust bearing on the main coolant pump bearing in the newly developing nuclear reactor named SMART(System-integrated Modular Advanced ReacTor). Operating condition of the bearings is realized by the tribometer and the autoclave. Friction coefficient and wear loss are analyzed to choose the best silicon graphite material. Pin on plate test specimens are used and coned disk springs are used to control the applied force on the specimens. Wear loss and wear width are measured by a precision balance and a micrometer. The friction force is measured by the strain gauge which can be used under high temperature and high pressure. Three kinds of silicon graphite materials are examined and compared with each other, and each material shows similar but different results on frictional and wear characteristics

  13. Individual Low-Energy Toroidal Dipole State in Mg 24

    Science.gov (United States)

    Nesterenko, V. O.; Repko, A.; Kvasil, J.; Reinhard, P.-G.

    2018-05-01

    The low-energy dipole excitations in Mg 24 are investigated within the Skyrme quasiparticle random phase approximation for axial nuclei. The calculations with the force SLy6 reveal a remarkable feature: the lowest IπK =1-1 excitation (E =7.92 MeV ) in Mg 24 is a vortical toroidal state (TS) representing a specific vortex-antivortex realization of the well-known spherical Hill's vortex in a strongly deformed axial confinement. This is a striking example of an individual TS which can be much more easily discriminated in experiment than the toroidal dipole resonance embracing many states. The TS acquires the lowest energy due to the huge prolate axial deformation in Mg 24 . The result persists for different Skyrme parametrizations (SLy6, SVbas, SkM*). We analyze spectroscopic properties of the TS and its relation with the cluster structure of Mg 24 . Similar TSs could exist in other highly prolate light nuclei. They could serve as promising tests for various reactions to probe a vortical (toroidal) nuclear flow.

  14. Solubility of methane and carbon dioxide in ethylene glycol at pressures up to 14 MPa and temperatures ranging from (303 to 423) K

    International Nuclear Information System (INIS)

    Galvao, A.C.; Francesconi, A.Z.

    2010-01-01

    This work reports solubility data of methane and carbon dioxide in ethylene glycol and the Henry's law constant of each solute in the studied solvent at saturation pressure. The measurements were performed at (303, 323, 373, 398, and 423.15) K and pressures up to 6.3 MPa for mixtures containing carbon dioxide and pressures up to 13.7 MPa for mixtures containing methane. The experiments were performed in an autoclave type phase equilibrium apparatus using the total pressure method (synthetic method). All investigated systems show an increase of gas solubility with the increase of pressure. A decrease of carbon dioxide solubility with the increase of temperature and an increase of methane solubility with the increase of temperature was observed. From the variation of solubility with temperature, the partial molar enthalpy, and entropy change are calculated.

  15. Interactions of 29 MeV. He3 particles with light nuclei

    International Nuclear Information System (INIS)

    de la Rubia Pacheco, J.

    1964-01-01

    The interactions of 29 MeV He 3 particles with 32 S , 19 F and 12 C , irradiated in the Nuffield cyclotron (Birmingham University) have been studied using the nuclear emulsion technique. The first excitation levels of 12 C and 32 S have been obtained and the pick-up reaction 12 C (3 H e, 4 H e) 11 C has been studied and used to calculate its Q-values and the first levels of 1 C . (Author) 24 refs

  16. Me&i-myyjän taloushallinto -opas

    OpenAIRE

    Riipi, Jaana-Mari

    2015-01-01

    Opinnäytetyön toimeksiantajana toimi ruotsalaisen yrityksen Me&i:n Suomen osasto. Me&i myy lasten ja naisten vaatteita kotikutsuilla. Me&i:lla on Suomessa noin 280 toiminimellistä kotikutsumyyjää, jotka toimivat itsenäisinä ammatinharjoittajina ympäri maata. Me&i-myyjien keskuudessa on noussut esiin toive saada Me&i:lta apua ja ohjeistusta kirjanpidollisissa ja verotuksellisissa asioissa. Tämän vuoksi päätettiin tehdä opas, joka kattaa Me&i-myyjän taloushallinnon tärkeimmät osa-alueet. Op...

  17. Electric properties of La2O3/SiO2/4H-SiC MOS capacitors with different annealing temperatures

    Directory of Open Access Journals (Sweden)

    Yucheng Wang

    2015-08-01

    Full Text Available In this work, we describe a rapid thermal annealing (RTA process for the La2O3/SiO2/4H-SiC interface and investigate its effect on the material’s electrical properties. Our results indicate that the trap charge density and interface state density (Dit are reduced as the RTA temperature increases due to the termination of residual carbon and dangling bonds. We demonstrate that the sample obtained after RTA at 500 °C has the highest breakdown electric field (Efb (7 MV/cm due to a decrease in the trap charge density and an improvement in the interfacial properties. However, when the RTA temperature reaches 600 °C or higher, a lower Efb value (1.2 MV/cm is obtained due to leakage routes generated by the crystallization of La2O3. Based on our results, we conclude that the ideal choice for the RTA temperature is 500 °C.

  18. JST Thesaurus Headwords and Synonyms: 膜分離 [MeCab user dictionary for science technology term[Archive

    Lifescience Database Archive (English)

    Full Text Available MeCab user dictionary for science technology term 膜分離 名詞 サ変接続 * * * * 膜分離 マクブンリ マクブンリ Thesaurus2015 200906054518340068 C CA24/CC03 MULTI_WORD 膜 分離

  19. Temperature profile data from XBT casts in a world wide distribution from multiple platforms from 20 February 2003 to 24 April 200 (NODC Accession 0001019)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Temperature profile data were collected using CTD casts from LYKES RAIDER and other platforms in a world wide distribution from 20 February 2003 to 24 April 2003....

  20. Temperature compensated photovoltaic array

    Science.gov (United States)

    Mosher, Dan Michael

    1997-11-18

    A temperature compensated photovoltaic module (20) comprised of a series of solar cells (22) having a thermally activated switch (24) connected in parallel with several of the cells (22). The photovoltaic module (20) is adapted to charge conventional batteries having a temperature coefficient (TC) differing from the temperature coefficient (TC) of the module (20). The calibration temperatures of the switches (24) are chosen whereby the colder the ambient temperature for the module (20), the more switches that are on and form a closed circuit to short the associated solar cells (22). By shorting some of the solar cells (22) as the ambient temperature decreases, the battery being charged by the module (20) is not excessively overcharged at lower temperatures. PV module (20) is an integrated solution that is reliable and inexpensive.

  1. A gas ionisation Direct-STIM detector for MeV ion microscopy

    International Nuclear Information System (INIS)

    Norarat, Rattanaporn; Guibert, Edouard; Jeanneret, Patrick; Dellea, Mario; Jenni, Josef; Roux, Adrien; Stoppini, Luc; Whitlow, Harry J.

    2015-01-01

    Direct-Scanning Transmission Ion Microscopy (Direct-STIM) is a powerful technique that yields structural information in sub-cellular whole cell imaging. Usually, a Si p-i-n diode is used in Direct-STIM measurements as a detector. In order to overcome the detrimental effects of radiation damage which appears as a broadening in the energy resolution, we have developed a gas ionisation detector for use with a focused ion beam. The design is based on the ETH Frisch grid-less off-axis Geiger–Müller geometry. It is developed for use in a MeV ion microscope with a standard Oxford Microbeams triplet lens and scanning system. The design has a large available solid angle for other detectors (e.g. proton induced fluorescence). Here we report the performance for imaging ReNcells VM with μm resolution where energy resolutions of <24 keV fwhm could be achieved for 1 MeV protons using isobutane gas

  2. Role of hydrothermal temperature on crystallinity ...

    Indian Academy of Sciences (India)

    M MALLIGAVATHY

    2018-02-22

    Feb 22, 2018 ... dioxide in a wide range of pressure (0–28 GPa) and temperature (0–1200 K) ... Jianxiang Lowet al[9] discussed the photocatalytic CO2 reduction mechanism, ..... MeO absorbs the light in both the UV and visible region with a ...

  3. 27 CFR 30.24 - Specific gravity hydrometers.

    Science.gov (United States)

    2010-04-01

    ... hydrometers. 30.24 Section 30.24 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE... hydrometers. (a) The specific gravity hydrometers furnished by proprietors to appropriate TTB officers shall... instruments. Such specific gravity hydrometers shall be of a precision grade, standardization temperature 60...

  4. Temperature-dependent charge injection and transport in pentacene thin-film transistors

    International Nuclear Information System (INIS)

    Kim, Dong Wook; Shin, Hyunji; Choi, Jong Sun; Park, Ji-Ho; Park, Jaehoon

    2015-01-01

    The electrical characteristics of p-channel pentacene thin-film transistors (TFTs) were analyzed at different operating temperatures ranging from 253 to 353 K. An improvement in the drain current and field-effect mobility of the pentacene TFTs is observed with increasing temperature. From the Arrhenius plots of field-effect mobility extracted at various temperatures, a lower activation energy of 99.34 meV was obtained when the device is operating in the saturation region. Such observation is ascribed to the thermally activated hole transport through the pentacene grain boundaries. On the other hand, it was found that the Au/pentacene contact significantly affects the TFTs electrical characteristics in the linear region, which resulted in a higher activation energy. The activation energy based on the linear field-effect mobility, which increased from 344.61 to 444.70 meV with decreasing temperature, implies the charge-injection-limited electrical behavior of pentacene TFTs at low temperatures. The thermally induced electrical characteristic variations in pentacene TFTs can thus be studied through the temperature dependence of the charge injection and transport processes. (paper)

  5. Measurement of formation cross sections producing short-lived nuclei by 14 MeV neutrons. Pr, Ba, Ce, Sm, W, Sn, Hf

    International Nuclear Information System (INIS)

    Murahira, S.; Satoh, Y.; Honda, N.; Shibata, M.; Yamamoto, H.; Kawade, K.; Takahashi, A.; Iida, T.

    1996-01-01

    Thirteen neutron activation cross sections for (n,2n), (n,p), (n,np) and (n,α) reactions producing short-lived nuclei with half-lives between 56 s and 24 min were measured in the energy range from 13.4 MeV to 14.9 MeV for Pr, Ba, Ce, Sm, W, Sn and Hf. The cross sections of 179 Hf(n,np) 178m Lu and 180 Hf(n,p) 180 Lu were measured for the first time. (author)

  6. Effect of 1.5 MeV electron irradiation on β-Ga2O3 carrier lifetime and diffusion length

    Science.gov (United States)

    Lee, Jonathan; Flitsiyan, Elena; Chernyak, Leonid; Yang, Jiancheng; Ren, Fan; Pearton, Stephen J.; Meyler, Boris; Salzman, Y. Joseph

    2018-02-01

    The influence of 1.5 MeV electron irradiation on minority transport properties of Si doped β-Ga2O3 vertical Schottky rectifiers was observed for fluences up to 1.43 × 1016 cm-2. The Electron Beam-Induced Current technique was used to determine the minority hole diffusion length as a function of temperature for each irradiation dose. This revealed activation energies related to shallow donors at 40.9 meV and radiation-induced defects with energies at 18.1 and 13.6 meV. Time-resolved cathodoluminescence measurements showed an ultrafast 210 ps decay lifetime and reduction in carrier lifetime with increased irradiation.

  7. Isobar separation of 93Zr and 93Nb at 24 MeV with a new multi-anode ionization chamber

    International Nuclear Information System (INIS)

    Martschini, Martin; Buchriegler, Josef; Collon, Philippe; Kutschera, Walter; Lachner, Johannes; Lu, Wenting; Priller, Alfred; Steier, Peter; Golser, Robin

    2015-01-01

    93 Zr with a half-life of 1.6 Ma is produced with high yield in nuclear fission, and thus should be present as a natural or anthropogenic trace isotope in all compartments of the general environment. Sensitive measurements of this isotope would immediately find numerous applications, however, its detection at sufficiently low levels has not yet been achieved. AMS measurements of 93 Zr suffer from the interference of the stable isobar 93 Nb. At the Vienna Environmental Research Accelerator VERA a new multi-anode ionization chamber was built. It is optimized for isobar separation in the medium mass range and is based on the experience from AMS experiments of 36 Cl at our 3-MV tandem accelerator facility. The design provides high flexibility in anode configuration and detector geometry. After validating the excellent energy resolution of the detector with 36 S, it was recently used to study iron–nickel and zirconium–niobium–molybdenum isobar separation. To our surprise, the separation of 94 Zr (Z = 40) from 94 Mo (Z = 42) was found to be much better than that of 58 Fe (Z = 26) from 58 Ni (Z = 28), despite the significantly larger ΔZ/Z of the latter pair. This clearly contradicts results from SRIM-simulations and suggests that differences in the stopping behavior may unexpectedly favor identification of 93 Zr. At 24 MeV particle energy, a 93 Nb (Z = 41) suppression factor of 1000 is expected based on a synthetic 93 Zr spectrum obtained by interpolation between experimental spectra from the two neighboring stable isotopes 92 Zr and 94 Zr. Assuming realistic numbers for chemical niobium reduction, a detection level of 93 Zr/Zr below 10 −9 seems feasible.

  8. Liquefaction of Warukin Formation Coal, Barito Basin, South Kalimantan on Low Pressure and Low Temperature

    Directory of Open Access Journals (Sweden)

    Edy Nursanto

    2013-06-01

    Full Text Available Research focusing on the quality of coal in Warukin Formation has been conducted in coal outcrops located on Tabalong area, particularly in 3 coal seams, namely Wara 120 which consists of low rank coal (lignite. Meanwhile, coals in seam Tutupan 210 and Paringin 712 are medium rank coal (sub-bituminous. Coal liquefaction is conducted in an autoclave on low pressure and temperature. Pressure during the process is 14 psi and temperature is 120oC. Catalyst used are alumina, hydrogen donor NaOH and water solvent. Liquefaction is conducted in three times variables of 30 minutes, 60 minutes and 90 minutes. This process shows following yield : Wara seam 120: 25.37% - 51.27%; Tutupan seam 210: 3.02%-15.45% and seam Paringin 712:1.99%-11.95%. The average result of yield shows that coals in seam Wara has higher yield conversion than coals in seam Tutupan and Paringin.

  9. JST Thesaurus Headwords and Synonyms: 水性ゾル [MeCab user dictionary for science technology term[Archive

    Lifescience Database Archive (English)

    Full Text Available MeCab user dictionary for science technology term 水性ゾル 名詞 一般 * * * * ヒドロゾル ヒドロゾル ヒドロゾル Thesaurus2015 200906059522009173 V CA24 UNKNOWN_2 水性 ゾル

  10. Thermal power generation during heat cycle near room temperature

    Science.gov (United States)

    Shibata, Takayuki; Fukuzumi, Yuya; Kobayashi, Wataru; Moritomo, Yutaka

    2018-01-01

    We demonstrate that a sodium-ion secondary battery (SIB)-type thermocell consisting of two types of Prussian blue analogue (PBA) with different electrochemical thermoelectric coefficients (S EC ≡ ∂V/∂T V and T are the redox potential and temperature, respectively) produces electrical energy during heat cycles. The device produces an electrical energy of 2.3 meV/PBA per heat cycle between 295 K (= T L) and 323 K (= T H). The ideal thermal efficiency (η = 1.0%), which is evaluated using the heat capacity (C = 4.16 meV/K) of ideal Na2Co[Fe(CN)6], reaches 11% of the Carnot efficiency (ηth = 8.7%). Our SIB-type thermocell is a promising thermoelectric device that harvests waste heat near room temperature.

  11. FY 1974 Report on results of Sunshine Project. Research and development of slurry serviceable under geothermal conditions; 1974 nendo chinetsu kankyoka de shiyo kanona deisui no kenkyu kaihatsu seika hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1975-05-30

    Summarized herein are the results of (1) surveys on autoclaves, (2) researches on water/clay-based slurry materials, and (3) surveys on and designs of spent slurry treatment test systems. For the item (1), the autoclaves serviceable at normal working temperature of 250 degrees C and pressure of 500 kg/cm{sup 2} for testing slurry materials were surveyed, to set the maximum temperature of 300 degrees C and pressure of 300 kg/cm{sup 2} and volume of 200 cc. The autoclave satisfying the above conditions is to be purchased. For the item (2), surveys are still underway on agents, e.g., dispersantsand and deflocculants currently available both in Japan and abroad as the slurry components. Several types of dispersants and deflocculants were tested with slurries of low-solid suspensions containing 3 to 5 wt.% of bentonite, to follow their properties changing with content of the agent by a viscometer serviceable at high temperature and pressure, when the slurries are thermally treated at 150 to 200 degrees C. At the same time, the dispersants and deflocculants currently used were tested by an autoclave to follow thermal changes at 200 degrees C by an infrared spectrophotometer. For the item (3), surveys were conducted on spent slurry treatment test systems necessary for studying treatment of spent water/clay-based slurries. (NEDO)

  12. Hamiltonian approach to QCD in Coulomb gauge at zero and finite temperature

    Directory of Open Access Journals (Sweden)

    Reinhardt H.

    2017-01-01

    Full Text Available I report on recent results obtained within the Hamiltonian approach to QCD in Coulomb gauge. By relating the Gribov confinement scenario to the center vortex picture of confinement it is shown that the Coulomb string tension is tied to the spatial string tension. For the quark sector a vacuum wave functional is used which results in variational equations which are free of ultraviolet divergences. The variational approach is extended to finite temperatures by compactifying a spatial dimension. For the chiral and deconfinement phase transition pseudo-critical temperatures of 170MeV and 198 MeV, respectively, are obtained.

  13. Accurate branching ratio measurements in 23Na(p,γ)24Mg

    International Nuclear Information System (INIS)

    Boydell, S.G.; Sargood, D.G.

    1975-01-01

    The reaction 23 Na(p,γ) 24 Mg has been investigated in the proton energy range 0.3-1.75 MeV. Gamma ray spectra were measured for 22 resonances with Ge(Li) detectors which were carefully calibrated for relative peak efficiencies. Allowance was made for the effect of anisotropies in all the emitted γ-rays. The spectra have been analysed to give branching ratios for bound and unbound levels. (author)

  14. The Effect of Artificial Aging on the Tensile Properties of Alclad 24S-T and 24S-T Aluminum Alloy

    Science.gov (United States)

    Kotanchik, Joseph N.; Woods, Walter; Zender, George W.

    1943-01-01

    An experimental study was made to determine the effect of artificial aging on the tensile properties of alclad 24S-T and 24S-T aluminum-alloy sheet material. The results of the tests show that certain combinations of aging time and temperature cause a marked increase in the yield strength and a small increase in the ultimate strength; these increases are accompanied by a very large decrease in elongation. A curve is presented that shows the maximum yield strengths that can be obtained by aging this material at various combinations of time and temperature. The higher values of yield stress are obtained in material aged at relatively longer times and lower temperatures.

  15. Elimination Reactions of (E)-2,4,6-Trinitrobenzaldehyde O-benzoyloximes Promoted by R2NH in MeCN. Change of Reaction Mechanism

    International Nuclear Information System (INIS)

    Cho, Bong Rae; Pyun, Sang Yong

    2010-01-01

    We have studied the nitrile-forming elimination reactions from 1 promoted by R 2 NH in MeCN. The reaction proceeded by (E1cb) irr mechanism. Change of the β-aryl group from 2,4-dinitrophenyl to a more strongly electron-withdrawing 2,4,6-trinitrophenyl increased the reaction rate by 470-fold, shifted the transition state toward more reactant-like, and changed the reaction mechanism from E2 to (E1cb) irr . To the best of our knowledge, this is the first example of nitrile-forming elimination reaction that proceeds by the (E1cb) irr mechanism in MeCN. Noteworthy is the carbanion stabilizing ability of the 2,4,6-trinitrophenyl group in aprotic solvent. Nitrile-forming elimination reactions of (E)-benzaldoxime derivatives have been extensively investigated under various conditions. The reactions proceeded by the E2 mechanism in MeCN despite the fact that the reactants have syn stereochemistry, poor leaving, and sp 2 hybridized β-carbon atom, all of which favor E1cb- or E1cb-like transition state. Moreover, the transition state structures were relatively insensitive to the variation of the reactant structures. The results have been attributed to the poor anion solvating ability of MeCN, which favors E2 transition state with maximum charge dispersal. For eliminations from strongly activated (E)-2,4-(NO 2 ) 2 C 6 H 3 CH=NOC(O)C 6 H 4 X, a change in the reaction mechanism from E2 to (E1cb) irr was observed as the base-solvent was changed from R 2 NH in MeCN to R 2 NH/R 2 NH 2 + in 70 mol % MeCN(aq). A combination of a strong electron-withdrawing β-aryl group and anion-solvating protic solvent was required for the mechanistic change

  16. Air-ground temperature coupling and subsurface propagation of annual temperature signals

    Czech Academy of Sciences Publication Activity Database

    Smerdon, J. E.; Pollack, H. N.; Čermák, Vladimír; Enz, J. W.; Krešl, Milan; Šafanda, Jan; Wehmiller, J. F.

    2004-01-01

    Roč. 109, D21 (2004), D21107/1-10 ISSN 0148-0227 R&D Projects: GA AV ČR KSK3046108; GA MŠk(CZ) 1P05ME778 Grant - others:NSF(US) ATM-0081864; NSF(US) EAR9315052; NASA (US) GWEC 0000 0132 Institutional research plan: CEZ:AV0Z3012916 Keywords : heat transport * air-ground temperature coupling * paleoclimate Subject RIV: DB - Geology ; Mineralogy Impact factor: 2.839, year: 2004

  17. Oxidative stress in MeHg-induced neurotoxicity

    Energy Technology Data Exchange (ETDEWEB)

    Farina, Marcelo, E-mail: farina@ccb.ufsc.br [Departamento de Bioquimica, Centro de Ciencias Biologicas, Universidade Federal de Santa Catarina, Florianopolis, SC (Brazil); Aschner, Michael [Department of Pediatrics, Vanderbilt University Medical Center, Nashville, TN (United States); Department of Pharmacology, Vanderbilt University Medical Center, Nashville, TN (United States); Rocha, Joao B.T., E-mail: jbtrocha@yahoo.com.br [Departamento de Quimica, Centro de Ciencias Naturais e Exatas, Universidade Federal de Santa Maria, Santa Maria, RS (Brazil)

    2011-11-15

    Methylmercury (MeHg) is an environmental toxicant that leads to long-lasting neurological and developmental deficits in animals and humans. Although the molecular mechanisms mediating MeHg-induced neurotoxicity are not completely understood, several lines of evidence indicate that oxidative stress represents a critical event related to the neurotoxic effects elicited by this toxicant. The objective of this review is to summarize and discuss data from experimental and epidemiological studies that have been important in clarifying the molecular events which mediate MeHg-induced oxidative damage and, consequently, toxicity. Although unanswered questions remain, the electrophilic properties of MeHg and its ability to oxidize thiols have been reported to play decisive roles to the oxidative consequences observed after MeHg exposure. However, a close examination of the relationship between low levels of MeHg necessary to induce oxidative stress and the high amounts of sulfhydryl-containing antioxidants in mammalian cells (e.g., glutathione) have led to the hypothesis that nucleophilic groups with extremely high affinities for MeHg (e.g., selenols) might represent primary targets in MeHg-induced oxidative stress. Indeed, the inhibition of antioxidant selenoproteins during MeHg poisoning in experimental animals has corroborated this hypothesis. The levels of different reactive species (superoxide anion, hydrogen peroxide and nitric oxide) have been reported to be increased in MeHg-exposed systems, and the mechanisms concerning these increments seem to involve a complex sequence of cascading molecular events, such as mitochondrial dysfunction, excitotoxicity, intracellular calcium dyshomeostasis and decreased antioxidant capacity. This review also discusses potential therapeutic strategies to counteract MeHg-induced toxicity and oxidative stress, emphasizing the use of organic selenocompounds, which generally present higher affinity for MeHg when compared to the classically

  18. Formation and de-excitation of very hot nuclei in Ar + Au collisions at 30 and 60 MeV/nucleon

    International Nuclear Information System (INIS)

    Hamdani, T.

    1993-10-01

    The study of the formation and the de-excitation of very hot nuclei by using collisions between Ar and Au at 30 and 60 MeV/u is presented in this work. The detection system consisted of three multidetectors for fragments (DELF) or light particles (TONNEAU+MUR) plus two groups of four detectors (Silicium, CsI). This system and the triggering conditions adopted allowed the selection of two classes of events: semiperipheral collisions and central collisions. The studies presented using global variables, show clearly that the fragments produced in the reactions are emitted from an equilibrated source. Hence, an event generator based on the statistical model was employed to verify the method of calculation of the excitation energy of the source. It also provides information concerning experimental biases and the sensitivity of some of the global variables used in the experimental analysis. A detailed study of the temperatures of hot nuclei is presented using the data recorded with the CsI detectors. The temperatures measured reached up to 7 MeV for the reaction at 60 MeV/u. (orig.)

  19. JST Thesaurus Headwords and Synonyms: エアゾル [MeCab user dictionary for science technology term[Archive

    Lifescience Database Archive (English)

    Full Text Available MeCab user dictionary for science technology term エアゾル 名詞 一般 * * * * エアロゾル エアロゾル エアロゾル Thesaurus2015 200906079540623211 V CA24/GC19 UNKNOWN_1 エアゾル

  20. Target irradiation facility and targetry development at 160 MeV proton beam of Moscow linac

    CERN Document Server

    Zhuikov, B L; Konyakhin, N A; Vincent, J

    1999-01-01

    A facility has been built and successfully operated with the 160 MeV proton beam of Moscow Meson factory LINAC, Institute for Nuclear Research (INR) of Russian Academy of Science, Troitsk. The facility was created for various isotope production goals as well as for fundamental nuclear investigations at high intensity beam (100 mu A and more). An important part of the facility targetry system is a high-intensity beam monitoring collimator device. Measurements of the temperature distribution between collimator sectors, cooling water flow and temperature, and the beam current, provide an opportunity to compute beam losses and beam position. The target holder design allows easy insertion by manipulator and simultaneous bombardment of several different targets of various types and forms, and variation of proton energy on each target over a wide range below 160 MeV. The main target utilized for commercial sup 8 sup 2 Sr isotope production is metallic rubidium in a stainless-steel container. A regular wet chemistry ...

  1. J-GLOBAL MeSH Dictionary: Sphingomonadaceae [MeCab user dictionary for science technology term[Archive

    Lifescience Database Archive (English)

    Full Text Available MeCab user dictionary for science technology term Sphingomonadaceae 名詞 一般 * * * * Sphi...ngomonadaceae ... MeSH D042301 200906094653102667 C LS07 UNKNOWN_1 Sphingomonadaceae

  2. J-GLOBAL MeSH Dictionary: Piscirickettsiaceae [MeCab user dictionary for science technology term[Archive

    Lifescience Database Archive (English)

    Full Text Available MeCab user dictionary for science technology term Piscirickettsiaceae 名詞 一般 * * * * Piscirickettsia...ceae ... MeSH D044147 200906033138096892 C LS07 UNKNOWN_1 Piscirickettsiaceae

  3. J-GLOBAL MeSH Dictionary: Heligmosomatoidea [MeCab user dictionary for science technology term[Archive

    Lifescience Database Archive (English)

    Full Text Available MeCab user dictionary for science technology term Heligmosomatoidea 名詞 一般 * * * * Heligmos...omatoidea ... MeSH D006369 200906085224079623 C LS05 UNKNOWN_1 Heligmosomatoidea

  4. Dizocilpine and reduced body temperature do not prevent methamphetamine-induced neurotoxicity in the vervet monkey: [11C]WIN 35,428 - positron emission tomography studies.

    Science.gov (United States)

    Melega, W P; Lacan, G; Harvey, D C; Huang, S C; Phelps, M E

    1998-12-11

    [11C]WIN 35,428 (WIN), a cocaine analog that binds to the dopamine transporter (DAT), and positron emission tomography (PET) were used to evaluate the potential neuroprotective effects of dizocilpine (MK-801) on methamphetamine (MeAmp) induced neurotoxicity in the striatal dopamine system of the vervet monkey. MK-801 (1 mg/kg, i.m.) was administered 30 min prior to a neurotoxic MeAmp dosage for this species (2 x 2 mg/kg, 4 h apart); control subjects received MeAmp. MK-801 treated subjects were anesthetized by the drug for 6-8 h; throughout that period, a 2-3 degrees C decrease in body temperature was measured. At 1-2 weeks post-MeAmp, decreases of approximately 75% in striatal WIN binding were observed for both MK-801/MeAmp and MeAmp subjects. Thus, in this non-human primate species, the combination of MK-801 pretreatment and reduced body temperature did not provide protection from the MeAmp-induced loss of DAT. Further, the absence of an elevated body temperature during the acute MeAmp exposure period indicated that hyperthermia, per se, was not a necessary concomitant of the MeAmp neurotoxicity profile as has been previously demonstrated in rodents. These results provide evidence that different regulatory factors maintain the integrity of the rodent and primate striatal dopamine systems.

  5. Low temperature irradiation effects on iron-boron based amorphous metallic alloys

    International Nuclear Information System (INIS)

    Audouard, Alain.

    1983-01-01

    Three iron-boron amorphous alloys and the crystalline Fe 3 B alloy have been irradiated at liquid hydrogen temperature. 2,4 MeV electron irradiation induces the creation of point defects in the amorphous alloys as well as in the crystalline Fe 3 B alloy. These point defects can be assimilated to iron ''Frenkel pairs''. They have been characterized by determining their intrinsic electrical resistivity and their formation volume. The displacement threshold energy of iron atoms has also been determined. 10 B fission fragments induce, in these amorphous alloys, displacement cascades which lead to stable vacancy rich zones. This irradiation also leads to a structural disorder in relation with the presence of defects. 235 U fission fragments irradiation modifies drastically the structure of the amorphous alloys. The results have been interpreted on the basis of the coexistence of two opposite processes which induce local disorder and crystallisation respectively [fr

  6. Atmospheric volatilization of methyl bromide, 1,3-dichloropropene, and propargyl bromide through two plastic films: transfer coefficient and temperature effect

    Science.gov (United States)

    Wang, D.; Yates, S. R.; Gan, J.; Knuteson, J. A.

    Atmospheric emission of methyl bromide (MeBr) and its potential alternative chemicals such as 1,3-dichloropropene (1,3-D) and propargyl bromide (PrBr) can contribute to air pollution and ozone depletion (for MeBr). One of the main sources of these chemicals is from agricultural soil fumigation. To understand the volatilization dynamics, emission of MeBr, 1,3-D, and PrBr through a polyethylene-based high-barrier film (HBF) and a virtually impermeable film (VIF) was measured using an air flow and sampling system that produced >90% mass balance. The experiment was conducted outdoors and was subjected to ambient daily temperature variations. The HBF film was found to be very permeable to 1,3-D and PrBr, but somewhat less permeable to MeBr. The VIF film was very impermeable to 1,3-D, PrBr, or MeBr. Measured volatilization flux, in general, exhibited strong diurnal variations which were controlled by film temperature. Unlike the HBF film, a time lag (˜12 h) was observed between high-temperatures and high-emission flux values for the VIF film. An impermeable film may be used as an effective means of controlling the atmospheric emission of MeBr and its alternative chemicals.

  7. Separation of reaction mechanisms at low energy. Study of the reactions: 27Al(d,p) 28Al, 24Mg(d,p) 25Mg, and 24Mg(d, α) 22Na

    International Nuclear Information System (INIS)

    Mermaz, M.

    1966-06-01

    The two sets of angular distributions of (d,p) reactions on Al and Mg, measured between 2 and 6 MeV, have given the possibility to test, in analysing the statistical fluctuations of cross-section, the validity of the separation of their mean values in two parts, one 'direct', another given by the statistical mechanism. With the same method of analysis we have studied excitation functions for several alpha groups of the reaction 24 Mg(d, α) 22 Na and given an evidence for an intermediate structure for the alpha channel leading to the 3. excited state of 22 Na. The angular distribution of the wide resonance at 15.9 MeV in 26 Al has been obtained. (author) [fr

  8. Method of processing radioactive rare gase

    International Nuclear Information System (INIS)

    Tagusagawa, Atsushi; Tuda, Kazuaki.

    1988-01-01

    Purpose: To obtain a safety processing method without using mechanical pumps or pressure-proof containers and, accordingly, with no risk for the leakage of radioactive rare gas. Method: A container filled with zeolige is inserted with a cover being opened into an autoclave. Meanwhile, krypton-containing gases are supplied to an adsorption tower filled with adsorbents, cooled, adsorbed and then heated to desorb adsorbed krypton. The krypton-containing gases are introduced due to the pressure difference to the autoclave thereby causing krypton to adsorb at ambient temperature to zeolite. Then, the inside of the autoclave is heated to desorb krypton and adsorbed moistures from zeolite and the pressure is elevated. After sending the gases under pressure to the adsorption tower, the zeolite-filled container is taken out from the autoclave, tightly closed and then transferred to a predetermined site. (Takahashi, M.)

  9. Electromagnon Resonance at Room Temperature with Gigantic Magnetochromism

    Science.gov (United States)

    Shishikura, H.; Tokunaga, Y.; Takahashi, Y.; Masuda, R.; Taguchi, Y.; Kaneko, Y.; Tokura, Y.

    2018-04-01

    The elementary excitation characteristic of magnetoelectric (ME) multiferroics is a magnon endowed with electric activity, which is referred to as an electromagnon. The electromagnon resonance mediated by the bilinear exchange coupling potentially exhibits strong terahertz light-matter interaction with optical properties different from the conventional magnon excitation. Here we report the robust electromagnon resonance on helimagnetic Y -type hexaferrites in a wide temperature range including room temperature. Furthermore, the efficient magnetic field controls of the electromagnon are demonstrated on the flexible spin structure of these compounds, leading to the generation or annihilation of the resonance as well as the large resonance energy shift. These terahertz characteristics of the electromagnon exemplify the versatile magneto-optical functionality driven by the ME coupling in multiferroics, paving a way for possible terahertz applications as well as terahertz control of a magnetic state of matter.

  10. A 100 MeV linac for the SR light source

    International Nuclear Information System (INIS)

    Iwata, H.; Takahashi, T.; Kaneko, N.; Nakashizu, T.; Hara, O.

    1992-01-01

    A 4 m long linear accelerator has been designed to operate with the energy gain of 100 MeV and a beam current of 100 mA. It is scheduled to be installed into the compact synchrotron radiation light source (LUNA) in near future. In this report, several pre-tests and the design of this linac are discussed. High power testing by a 0.5 m long test linac shows that it takes 110 hr aging to reach no arcing condition at an electric field strength of 25 MeV/m. Another diffusion bonding test shows that it is possible to make the deformation less than 5μm per cell under optimum conditions of temperature and pressure. This linac is composed of 5 units, made by diffusion bonding. Each unit is bolted together to form a 4 m long linear accelerator. The entire assembly is placed within a cylinder which serves both as a vacuum envelope and as the support structure. (Author) 5 figs., 2 tabs

  11. Photospallation reactions of 133Cs and 139La by 100 MeV- and 200 MeV bremsstrahlungs

    International Nuclear Information System (INIS)

    Sakamoto, K.; Toramoto, H.; Hamajima, Y.; Okada, K.; Dohniwa, M.

    1984-01-01

    Spallation yields relative to the 196 Au yield from 197 Au(γ,n) of 26 to 46 nuclides of Sb, Te, I, Xe, Cs and/or Ba and La from 133 Cs and 139 La targets irradiated with bremsstrahlungs of end energies of 100 MeV and 200 MeV were radiochemically determined. The isomeric yield ratios for 132 La and 131 Ba from the ( 139 La + 100 MeV-γ), 132 La, 131 Ba, 121 Te and 119 Te from the ( 139 La + 200 MeV-γ, and 120 I, 121 Te and 119 Te from the ( 133 Cs +- 200 MeV-γ) were also determined. The isotopic yields from the (γ,yn) reactions decrease exponentially with increase of y up to 5, and show no dependence on energy and targets studied, indicating that the reactions of a few neutron emissions occur at energies lower than 100 MeV. When the product yields from the (γ,xpyn) reactions were plotted against (x + y) for each x (isotopic distribution), a regular variation of the Gaussian distributions, typical of nuclear spallation, was observed. Isobaric mass distributions and charge dispersions were deduced to extract characteristic features of these reactions. The isobaric distributions due only to photons of 100 MeV to 200 MeV, which were obtained by subtracting the 100 MeV-yields from the 200 MeV-yields, are very close to a symmetric one peaking at about 8 amu from the target masses. Nuclear charges are also dispersed symmetrically, with most probable N/Zsub(p) of about 1.3 replaced by about 1 amu to the neutron-deficient side from the beta stability valley in all the cases studied. Parameters included in Rudstam's semi-empirical formula were examined by comparing with the observed yield curves. The P values of 0.45 and 0.65, chosen for a better fit to the 200 MeV data on 133 Cs and 139 La, respectively, were larger than the predictions reported in the literature. The magic number effects of 139 La may explain the target-differences in mass distributions. (orig.)

  12. Silk I and Silk II studied by fast scanning calorimetry.

    Science.gov (United States)

    Cebe, Peggy; Partlow, Benjamin P; Kaplan, David L; Wurm, Andreas; Zhuravlev, Evgeny; Schick, Christoph

    2017-06-01

    Using fast scanning calorimetry (FSC), we investigated the glass transition and crystal melting of samples of B. mori silk fibroin containing Silk I and/or Silk II crystals. Due to the very short residence times at high temperatures during such measurements, thermal decomposition of silk protein can be significantly suppressed. FSC was performed at 2000K/s using the Mettler Flash DSC1 on fibroin films with masses around 130-270ng. Films were prepared with different crystalline fractions (ranging from 0.26 to 0.50) and with different crystal structures (Silk I, Silk II, or mixed) by varying the processing conditions. These included water annealing at different temperatures, exposure to 50%MeOH in water, or autoclaving. The resulting crystal structure was examined using wide angle X-ray scattering. Degree of crystallinity was evaluated from Fourier transform infrared (FTIR) spectroscopy and from analysis of the heat capacity increment at the glass transition temperature. Silk fibroin films prepared by water annealing at 25°C were the least crystalline and had Silk I structure. FTIR and FSC studies showed that films prepared by autoclaving or 50%MeOH exposure were the most crystalline and had Silk II structure. Intermediate crystalline fraction and mixed Silk I/Silk II structures were found in films prepared by water annealing at 37°C. FSC results indicate that Silk II crystals exhibit endotherms of narrower width and have higher mean melting temperature T m (II)=351±2.6°C, compared to Silk I crystals which melt at T m (I)=292±3.8°C. Films containing mixed Silk I/Silk II structure showed two clearly separated endothermic peaks. Evidence suggests that the two types of crystals melt separately and do not thermally interconvert on the extremely short time scale (0.065s between onset and end of melting) of the FSC experiment. Silkworm silk is a naturally occurring biomaterial. The fibroin component of silk forms two types of crystals. Silk properties depend upon the

  13. J-GLOBAL MeSH Dictionary: Phoradendron属 [MeCab user dictionary for science technology term[Archive

    Lifescience Database Archive (English)

    Full Text Available MeCab user dictionary for science technology term Phoradendron属 名詞 サ変接続 * * * * Phoradendron...属 ... MeSH D028184 200906006893995689 C LS06 UNKNOWN_2 Phoradendron 属

  14. Structure in the 12C+ 12C and 8Be+16O fission width distribution of 24Mg observed via the reaction 12C(16O,α)24Mg(→X+Y)

    International Nuclear Information System (INIS)

    Lazzarini, A.J.; Steadman, S.G.; Ledoux, R.J.; Sperduto, A.; Young, G.R.; Van Bibber, K.; Cosman, E.R.

    1983-01-01

    Prominent gross and intermediate width structures are observed in the 12 C+ 12 C, 12 C+ 12 C((2 + ), 1 C((2 + )+ 12 C((2 + ), 8 Be+ 16 O, and 8 Be+ 16 O + (3 - , O + ) decay channels following 24 Mg* population via the 12 C( 16 O,α) 24 Mg reaction at E/sub c.m./ = 33 MeV. Evidence that the 12 C( 16 O,α) 24 Mg reaction populates states in 24 Mg which are associated with 12 C+ 12 C resonances is presented in the form of correlation analyses between the α+ 12 C+ 12 C three-body spectra and previously measured 12 C+ 12 C elastic and inelastic excitation functions. Direct determination of 12 C+ 12 C widths from these measurements is obscured by a background of other strong transitions which appear to be present in the 12 C( 16 O,α) 24 Mg singles spectrum

  15. Temperature profile data using XBT casts in the TOGA - Atlantic Ocean from NOAA Ship RESEARCH from 1979-07-10 to 1979-07-24 (NODC Accession 7900278)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Temperature profile data were collected using XBT casts from NOAA Ship RESEARCHER in the TOGA - Atlantic Ocean from 10 July 1979 to 24 July 1989. Data were submitted...

  16. JST Thesaurus Headwords and Synonyms: 有機ゾル [MeCab user dictionary for science technology term[Archive

    Lifescience Database Archive (English)

    Full Text Available MeCab user dictionary for science technology term 有機ゾル 名詞 一般 * * * * オルガノゾル オルガノゾル オルガノゾル Thesaurus2015 200906083190225487 V CA24/CC19 UNKNOWN_2 有機 ゾル

  17. Mutagenic potency of MMS-induced 1meA/3meC lesions in E. coli.

    Science.gov (United States)

    Nieminuszczy, Jadwiga; Mielecki, Damian; Sikora, Anna; Wrzesiński, Michał; Chojnacka, Aleksandra; Krwawicz, Joanna; Janion, Celina; Grzesiuk, Elzbieta

    2009-12-01

    The mutagenic activity of MMS in E. coli depends on the susceptibility of DNA bases to methylation and their repair by cellular defense systems. Among the lesions in methylated DNA is 1meA/3meC, which is recently recognized as being mutagenic. In this report, special attention is focused on the mutagenic properties of 1meA/3meC which, by the activity of AlkB-dioxygenase, are quickly and efficiently converted to natural A/C bases in the DNA of E. coli alkB(+) strains, preventing 1meA/3meC-induced mutations. We have found that in the absence of AlkB-mediated repair, MMS treatment results in an increased frequency of four types of base substitutions: GC-->CG, GC-->TA, AT-->CG, and AT-->TA, whereas overproduction of PolV in CC101-106 alkB(-)/pRW134 strains leads to a markedly elevated level of GC-->TA, GC-->CG, and AT-->TA transversions. It has been observed that in the case of AB1157 alkB(-) strains, the MMS-induced and 1meA/3meC-dependent argE3-->Arg(+) reversion occurs efficiently, whereas lacZ(-)--> Lac(+) reversion in a set of CC101-106 alkB(-) strains occurs with much lower frequency. We considered several reasons for this discrepancy, namely, the possible variance in the level of the PolV activity, the effect of the PolIV contents that is higher in CC101-106 than in AB1157 strains and the different genetic cell backgrounds in CC101-106 alkB(-) and AB1157 alkB(-) strains, respectively. We postulate that the difference in the number of targets undergoing mutation and different reactivity of MMS with ssDNA and dsDNA are responsible for the high (argE3-->Arg(+)) and low (lacZ(-) --> Lac(+)) frequency of MMS-induced mutations.

  18. Core body temperature in obesity.

    Science.gov (United States)

    Heikens, Marc J; Gorbach, Alexander M; Eden, Henry S; Savastano, David M; Chen, Kong Y; Skarulis, Monica C; Yanovski, Jack A

    2011-05-01

    A lower core body temperature set point has been suggested to be a factor that could potentially predispose humans to develop obesity. We tested the hypothesis that obese individuals have lower core temperatures than those in normal-weight individuals. In study 1, nonobese [body mass index (BMI; in kg/m(2)) temperature-sensing capsules, and we measured core temperatures continuously for 24 h. In study 2, normal-weight (BMI of 18-25) and obese subjects swallowed temperature-sensing capsules to measure core temperatures continuously for ≥48 h and kept activity logs. We constructed daily, 24-h core temperature profiles for analysis. Mean (±SE) daily core body temperature did not differ significantly between the 35 nonobese and 46 obese subjects (36.92 ± 0.03°C compared with 36.89 ± 0.03°C; P = 0.44). Core temperature 24-h profiles did not differ significantly between 11 normal-weight and 19 obese subjects (P = 0.274). Women had a mean core body temperature ≈0.23°C greater than that of men (36.99 ± 0.03°C compared with 36.76 ± 0.03°C; P body temperature. It may be necessary to study individuals with function-altering mutations in core temperature-regulating genes to determine whether differences in the core body temperature set point affect the regulation of human body weight. These trials were registered at clinicaltrials.gov as NCT00428987 and NCT00266500.

  19. Protonation and structural/chemical stability of Ln{sub 2}NiO{sub 4+δ} ceramics vs. H{sub 2}O/CO{sub 2}: High temperature/water pressure ageing tests

    Energy Technology Data Exchange (ETDEWEB)

    Upasen, S. [Sorbonne Universités, UPMC Univ Paris 06, UMR 8233, MONARIS, 75005 Paris (France); CNRS-IP2CT, UMR 8233, MONARIS, F-75005 Paris (France); Batocchi, P.; Mauvy, F. [ICMCB, ICMCB-CNRS-IUT-Université de Bordeaux, 33608 Pessac Cedex (France); Slodczyk, A. [Sorbonne Universités, UPMC Univ Paris 06, UMR 8233, MONARIS, 75005 Paris (France); CNRS-IP2CT, UMR 8233, MONARIS, F-75005 Paris (France); Colomban, Ph., E-mail: philippe.colomban@upmc.fr [Sorbonne Universités, UPMC Univ Paris 06, UMR 8233, MONARIS, 75005 Paris (France); CNRS-IP2CT, UMR 8233, MONARIS, F-75005 Paris (France)

    2015-02-15

    Highlights: • High temperature/water pressure autoclave is used to study the reaction/corrosion at SOFC/HTSE electrode. • High stability of Pr{sub 2}NiO{sub 4+δ} (PNO) and Nd{sub 2}NiO{sub 4+δ} (NNO) dense ceramics vs. water pressure is demonstrated. • Protonated rare-earth nickelates retain the perovskite-type structure and their H-content is determined. • Very low laser illumination power is required to avoid RE nickelate phase transition. • Nickelates show increasing stability from La to Pr/Nd vs. CO{sub 2}-rich high temperature water vapor. - Abstract: Mixed ionic-electronic conductors (MIEC) such as rare-earth nickelates with a general formula Ln{sub 2}NiO{sub 4+δ} (Ln = La, Pr, Nd) appear as potential for energy production and storage systems: fuel cells, electrolysers and CO{sub 2} converters. Since a good electrode material should exhibit important stability in operating conditions, the structural and chemical stability of different nickelate-based, well-densified ceramics have been studied using various techniques: TGA, dilatometry, XRD, Raman scattering and IR spectroscopy. Consequently, La{sub 2}NiO{sub 4+δ} (LNO), Pr{sub 2}NiO{sub 4+δ} (PNO) and Nd{sub 2}NiO{sub 4+δ} (NNO) have been exposed during 5 days to high water vapor pressure (40 bar) at intermediate temperature (550 °C) in an autoclave device, the used water being almost free or saturated with CO{sub 2}. Such protonation process offers an accelerating stability test and allows the choice of the most pertinent composition for industrial applications requiring a selected material with important life-time. In order to understand any eventual change of crystal structure, the ceramics were investigated in as-prepared, pristine state as well as after protonation and deprotonation (due to thermal treatment till 1000 °C under dry atmosphere). The results show the presence of traces or second phases originating from undesirable hydroxylation and carbonation, detected in the near

  20. Fusion cross sections for 6,7Li + 24Mg at energies around the barrier

    International Nuclear Information System (INIS)

    Ray, Maitreyi; Pradhan, M.K.; Kshetri, R.; Mukherjee, A.; Saha Sarkar, M.; Biswas, M.; Roy, S.; Basu, P.; Majumdar, H.; Dasmahapatra, B.; Sinha, M.; Palit, R.; Mazumdar, I.; Joshi, P.K.; Jain, H.C.

    2006-01-01

    The 6,7 Li + 24 Mg reactions in the energy interval E lab = 11-32 MeV using 6,7 Li beams have been investigated from the 14 UD BARC-TIFR Pelletron accelerator at TIFR, Mumbai. The γ-ray cross sections were measured using a Compton suppressed clover detector, placed at 55 deg with respect to the beam direction

  1. CONDUCTIVITY, WATER TEMPERATURE, and others collected from R/V Weatherbird II in Gulf of Mexico from 2013-06-24 to 2013-06-30 (NCEI Accession 0156593)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This dataset reports conductivity, temperature and depth data collected in the Northern Gulf of Mexico during the R/V Weatherbird II cruise WB-1318 from June 24-30th...

  2. Design of safety monitor system for operation sintering furnace ME-06

    International Nuclear Information System (INIS)

    Sugeng Rianto; Triarjo; Djoko Kisworo; Agus Sartono

    2013-01-01

    Design of safety monitoring system for safety operation of sinter furnace ME-06 has been done. Parameters monitored during this operation include: temperature, gas pressure, flow rate of gas, voltage and current furnace. For sintering furnace temperature system that monitored were the temperature of the furnace temperature, the temperature of the cooling water system inlet and outlet, temperature of flow hydrogen gas inlet and outlet. For pressure system and flow rate gas sinter furnace which monitored the pressure and flow rate of hydrogen gas inlet and outlet. The system also monitors current and voltage applied to the sinter furnace heating system. Monitor system hardware consists of: the system temperature sensor, pressure, rate and data acquisition systems. While software systems using the labview driver interface that connects the hard and software systems. Function test results during sintering operation for setting the temperature 1700 °C sintering temperature increases the ramp function by 250 °C/hour average measurements obtained when the sintering time 1707.016 °C with a standard deviation of 0.38 °C. The maximum temperature of the hydrogen gas temperature 35.4 °C. The maximum temperature of the cooling water system 27.4 °C. The maximum pressure of 1,911 bar Gas Inlet and outlet of 0,051 bar. Maximum inlet gas flow 12.996 L / min and outlet 14.086 L / min. (author)

  3. Temperature profile data from surface seawater intake, bucket, and XBT casts in a world wide distribution from 1995-02-24 to 1996-06-23 (NODC Accession 9700060)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Temperature profile data were collected using surface seawater intake, bucket, and XBT casts from several vessels in a world wide distribution from February 24,...

  4. Splitting of ISGMR strength in the light-mass nucleus 24Mg due to ground-state deformation

    Directory of Open Access Journals (Sweden)

    Y.K. Gupta

    2015-09-01

    Full Text Available The isoscalar giant monopole resonance (ISGMR strength distribution in 24Mg has been determined from background-free inelastic scattering of 386-MeV α particles at extreme forward angles, including 0∘. The ISGMR strength distribution has been observed for the first time to have a two-peak structure in a light-mass nucleus. This splitting of ISGMR strength is explained well by microscopic theory in terms of the prolate deformation of the ground state of 24Mg.

  5. Study of reaction mechanisms in 40Ar+68Zn interaction at 14.6 and 27.6 MeV/N

    International Nuclear Information System (INIS)

    Rami, F.

    1985-01-01

    The competing mechanisms in the 40 Ar+ 68 Zn reaction have been investigated at two bombarding energies: 14.6 and 27.6 MeV/nucleon. Mass, charge and energy spectra of the reaction products have been measured in a large angular range (3 0 0 ). The results show that important changes occur in this energy region. At 14.6 MeV/nucleon the production of the projectile-like fragments results mainly from deep inelastic and direct nucleon transfer reactions; while at 27.6 MeV/nucleon a strong component corresponding to process similar to projectile fragmentation is also observed. A distinction between the fragmentation process and direct transfer of few nucleons has been possible by analysing the linear momentum distributions of the detected fragments. The energy dependance of the fusion cross section indicates that this process should disappear for incident energies E/A > approximately 30 MeV/nucleon. The maximum temperature reached by the compound nucleus has been deduced i.e. Tmax approximately equal 7 MeV; this value is in agreement with recent theoretical predictions [fr

  6. Temperature dependent analysis of three classes of fluorescence spectra from p-6P nanofiber films

    DEFF Research Database (Denmark)

    Balzer, F.; Pogantsch, Alexander; Rubahn, Horst-Günter

    2009-01-01

    devices, given that the spectra are reproducible for varying surface temperatures. A detailed investigation as a function of surface temperature variation from 300 to 30 K reveals three classes of spectra: (a) spectra with well resolved excitonic peaks, which shift 35meV to the blue with decreasing...... temperature, (b) similar spectra with an additional intermediate broadening around 150 K, and (c) excitonic spectra similar to (b), but with a green defect emission band. Quantitative fitting of type (a) spectra results in an  exciton–phonon coupling factor of 80 ± 10meV and an average phonon temperature of Θ...... = 670 ± 70 K. The Huang–Rhys factor decreases linearly from 1.2 at 300 K to 1.0 at 30 K. Fitting of type (b) spectra reveals that the apparent intermediate temperature broadening is due to additional fluorescence peaks, the relative importance of which increasing with decreasing temperature....

  7. Measured neutron carbon kerma factors from 14.1 MeV to 18 MeV

    International Nuclear Information System (INIS)

    Deluca, P.M.; Barschall, H.H.; McDonald, J.C.

    1985-01-01

    For A-150 tissue-equivalent plastic, the total neutron kerma is dominated by the hydrogen kerma. Tissue kerma is inferred with reasonable accuracy by normalization to the kerma factor ratio between tissue and A-150 plastic. Because of the close match in the hydrogen abundance in these materials, the principal uncertainty is due to the kerma factors of carbon and oxygen. We have measured carbon kerma factor values of 0.183+-0.015 10 -8 cGy cm 2 and 0.210+-0.016 10 -8 cGy cm 2 at 14.1-MeV and 15-MeV neutron energy, respectively. A preliminary value of 0.297+-0.03 10 -8 cGy cm 2 has been determined at 17.9 MeV. A recent microscopic cross section measurement of the (n,n'3α) reaction in carbon at 14.1-MeV energy gives a kerma factor of 0.184+-0.019 10 -8 cGy cm 2 in agreement with the present result

  8. Synthesis of Highly Branched Polyolefins Using Phenyl Substituted α-Diimine Ni(II Catalysts

    Directory of Open Access Journals (Sweden)

    Fuzhou Wang

    2016-04-01

    Full Text Available A series of α-diimine Ni(II complexes containing bulky phenyl groups, [ArN = C(NaphthC = NAr]NiBr2 (Naphth: 1,8-naphthdiyl, Ar = 2,6-Me2-4-PhC6H2 (C1; Ar = 2,4-Me2-6-PhC6H2 (C2; Ar = 2-Me-4,6-Ph2C6H2 (C3; Ar = 4-Me-2,6-Ph2C6H2 (C4; Ar = 4-Me-2-PhC6H3 (C5; Ar = 2,4,6-Ph3C6H2 (C6, were synthesized and characterized. Upon activation with either diethylaluminum chloride (Et2AlCl or modified methylaluminoxane (MMAO, all Ni(II complexes showed high activities in ethylene polymerization and produced highly branched amorphous polyethylene (up to 145 branches/1000 carbons. Interestingly, the sec-butyl branches were observed in polyethylene depending on polymerization temperature. Polymerization of 1-alkene (1-hexene, 1-octene, 1-decene and 1-hexadecene with C1-MMAO at room temperature resulted in branched polyolefins with narrow Mw/Mn values (ca. 1.2, which suggested a living polymerization. The polymerization results indicated the possibility of precise microstructure control, depending on the polymerization temperature and types of monomers.

  9. JST Thesaurus Headwords and Synonyms: ヒドロゾル [MeCab user dictionary for science technology term[Archive

    Lifescience Database Archive (English)

    Full Text Available MeCab user dictionary for science technology term ヒドロゾル 名詞 一般 * * * * ヒドロゾル ヒドロゾル ヒドロゾル Thesaurus2015 200906059522009173 C CA24 UNKNOWN_1 ヒドロゾル

  10. JST Thesaurus Headwords and Synonyms: 反転ミセル [MeCab user dictionary for science technology term[Archive

    Lifescience Database Archive (English)

    Full Text Available MeCab user dictionary for science technology term 反転ミセル 名詞 一般 * * * * 逆ミセル ギャクミセル ギャクミセル Thesaurus2015 200906089419117053 V CA24 MULTI_WORD 反転 ミ セル

  11. Deuteron production in α-nucleus collisions from 200 to 800 MeV per nucleon

    International Nuclear Information System (INIS)

    Montarou, G.; Alard, J.P.; Augerat, J.; Fraysse, L.; Parizet, M.J.; Babinet, R.; Fodor, Z.; Girard, J.; Gosset, J.; Laspalles, C.; Lemaire, M.C.; L'Hote, D.; Lucas, B.; Poitou, J.; Schimmerling, W.; Terrien, Y.; Brochard, F.; Gorodetzky, P.; Racca, C.; Cugnon, J.; Vandermeulen, J.

    1991-01-01

    Deuteron spectra at laboratory angles from 30 degree to 90 degree were measured in α+(Pb, Cu, and C) collisions at 800, 600, and 200 MeV/nucleon, and α+(Pb and C) collisions at 400 MeV/nucleon. The coalescence relation between protons and deuterons was examined for the inclusive part of the spectra. The size of the interacting region was evaluated from the observed coalescence coefficients. The rms radius is typically 4--5 fm, depending of the target mass. The proton and deuteron energy spectra corresponding to central collisions were fitted assuming emission from a single source moving with a velocity intermediate between that of the projectile and the target. The extracted ''temperatures'' are independent of the nature of the emitted particle, indicating that the fragments have a common source. The best fits were achieved for 200- and 400-MeV/nucleon reactions. Spectra of deuteron-like pairs, including real deuterons and neutron-proton pairs that may be contained in a larger nuclear cluster, are compared to the prediction of an intranuclear cascade model incorporating a clustering algorithm based on a classical coalescence prescription. Best agreements between experimental and predicted deuteron-like spectra occur for 800- and 600-MeV/nucleon collisions

  12. MODELING THE RADIATION SHIELDING OF BORON NEUTRON CAPTURE THERAPY BASED ON 2.4 MEV D-D NEUTRON GENERATOR FACILITY

    Directory of Open Access Journals (Sweden)

    Muhammad Mu’Alim

    2018-01-01

    PEMODELAN PERISAI RADIASI PADA FASILITAS BORON NEUTRON CAPTURE THERAPY BERBASIS GENERATOR NEUTRON D-D 2,4 MeV. Telah dimodelkan perisai radiasi pada fasilitas Boron Neutron Capture Therapy (BNCT berbasis reaksi D-D pada Neutron Generator 2,4 MeV dengan Beam Shaping Assembly (BSA yang telah didesain sebelumnya. Pemodelan ini dilakukan untuk memperoleh suatu desain perisai radiasi untuk fasilitas BNCT berbasis generator neutron 2,4 MeV. Pemodelan dilakukan dengan cara memvariasikan bahan dan ketebalan perisasi radiasi. Bahan yang dipilih adalah beton barit, parafin, polietilen terborasi dan timbal. Perhitungan dilakukan menggunakan program MCNPX dengan tally F4 untuk menentukan laju dosis yang keluar dari perisai radiasi. Desain periasi radiasi dinyatakan optimal jika radiasi yang dihasilkan diluar perisai radiasi tidak melebihi Nilai Batas Dosis (NBD yang telah ditentukan oleh BAPETEN. Hasilnya, diperoleh suatu desain perisai radiasi menggunakan lapisan utama beton barit setebal 100 cm yang mengelilingi ruangan 100 cm x 100 cm x 166,4 cm dan polietilen terborasi 40 cm yang mengelilingi bahan beton barit. Kemudian ditambahkan beton barit 10 cm dan polietilen terborasi 10 cm untuk mengurangi radiasi primer yang lurus dari BSA setelah keluar dari lapisan utama. Laju dosis terbesar adalah 4,58 μSv·jam-1 pada sel 227 dan laju dosis rata-rata yang dihasilkan adalah sebesar 0,65 µSv·jam-1. Nilai laju dosis tersebut masih dibawah ambang batas NBD yang diperbolehkan oleh BAPETEN untuk pekerja radiasi. Kata kunci: Perisai radiasi, tally, laju dosis radiasi, BSA, BNCT

  13. Measurements of pp→π+d between 398 MeV and 572 MeV

    International Nuclear Information System (INIS)

    Aebischer, D.; Favier, B.; Greeniaus, L.G.; Hess, R.; Junod, A.; Lechanoine, C.; Nikles, J.-C.; Rapin, D.; Werren, D.W.

    1976-01-01

    The reaction pp→π + d was studied at incident proton energies of 398, 455, 497, 530 and 572 MeV. Measurements of dsigma/dΩ at 455 and 572 MeV show the presence of pion d-waves in the pion-deuteron system. Asymmetry measurements yield similar conclusions. Total cross-section measurements agree with recent fits to earlier data. (Auth.)

  14. The πNN coupling from high precision np charge exchange at 162 MeV

    International Nuclear Information System (INIS)

    Nilsson, J.; Blomgren, J.; Conde, H.; Elmgren, K.; Olsson, N.; Ericson, T.E.O.; Uppsala Univ.; Jonsson, O.; Nilsson, L.; Loiseau, B.; Ringbom, A.

    1995-02-01

    Differential cross sections for unpolarized neutrons of 162 MeV have been measured to high precision with particular attention to the absolute normalisation. These data can be extrapolated precisely and model-independently to the pion pole and give a πNN coupling constant g 2 =14.6±0.3 or f 2 =0.0808±0.0017. This is higher than recently suggested values. (author) 24 refs.; 3 figs.; 1 tab

  15. Corrosion of electron-irradiated Zr-2.5Nb and Zircaloy-2

    International Nuclear Information System (INIS)

    Woo, O.-T.; McDougall, G.M.; Hutcheon, R.M.; Urbanic, V.F.; Griffiths, M.; Coleman, C.E.

    2000-01-01

    We used 10-MeV electrons to rapidly produce radiation damage in zirconium alloys, investigated whether electrons produced the same microstructural changes as neutrons, then performed post-irradiation corrosion tests to determine whether electron-irradiated materials displayed similar corrosion behavior to neutron-irradiated materials. Two irradiations were completed using 10-MeV electrons with the beam normal to thin disks of material of 4 diameter slightly larger than the beam. The beam distribution. and disk cooling were designed to produce radial temperature and dose distributions having maxima at the disk center. A high-temperature irradiation was performed on annealed Zr-2.5Nb disks, achieving a central dose of 1.3 dpa and at a central temperature of ∼450 deg C. After irradiation, the samples contained needle-like β-Nb precipitates in the α-Zr matrix similar to those produced by neutrons. A low-temperature irradiation was performed on half-moon disks of Zr-2.5Nb and Zircaloy-2 pressure tube materials at 310 deg C central temperature and 1.3-dpa central dose. Dislocation loops were observed, again similar to those produced in neutron-irradiated materials. Some of the high-temperature electron-irradiated disks were exposed to 300 deg C moist air (saturated with D 2 O), and in separate tests, high- and low-temperature irradiated disks were corroded in 300 deg C D 2 0 (11.0 pD at room temperature) in an autoclave. Measurements of oxide thickness by Fourier Transform Infrared Reflectance (FTIR) spectroscopy showed that electron irradiation reduced the corrosion rate of Zr-2.5Nb compared with that of unirradiated material, as observed for neutron irradiation. For exposures to moist air and to D 2 O, the theoretical deuterium uptakes for the electron-irradiated materials were, respectively, about 4 times and 1.5 to 2 times those for the unirradiated materials. This is also in good agreement with results for neutron-irradiated pressure tube materials. Thus, 10-Me

  16. 1.5 MeV Kr+ irradiation of polycrystalline Ge

    International Nuclear Information System (INIS)

    Wang, L.M.; Birtcher, R.C.; Rehn, L.E.

    1990-01-01

    This paper reports 1.5 MeV Kr + irradiation of polycrystalline Ge at room temperature, and subsequent annealing carried out with in situ TEM observations. After a Kr + dose of 1.2 x 10 14 ions/cm 2 , Ge in the electron transparent region was completely amorphized. Continuous irradiation of the amorphized Ge resulted in a high density of small cavities. These cavities, first observed after 7 x 10 14 ions/cm 2 with an average diameter of ∼3 nm, grew into large (∼50 nm) irregular-shaped holes, transforming the irradiated Ge into a sponge-like material after 8.5 x 10 15 ions/cm 2 . The crystallization temperature and the morphology of the crystallized Ge after annealing were found to be dependent on the Kr + dose. The sponge-like structure was retained after crystallization at ∼600 degrees C

  17. Cluster ion-surface interactions: from meV to MeV energies

    Energy Technology Data Exchange (ETDEWEB)

    Nordlund, Kai; Meinander, Kristoffer; Jaervi, Tommi T.; Peltola, Jarkko; Samela, Juha [Accelerator Laboratory, University of Helsinki (Finland)

    2008-07-01

    The nature of cluster ion-surface interactions changes dramatically with the kinetic energy of the incoming cluster species. In this talk I review some of our recent work on the nature of cluster-surface interactions spanning an energy range from a few MeV/cluster to about 1 MeV/cluster and cluster sizes in the range of 10 - 1000 atoms/cluster. In the energy range of a few MeV/cluster ion, the kinetic energy of the incoming ion is insignificant compared to the energy gained when the surface potential energy at the cluster-surface interface is released and partly translated into kinetic energy. Even in this energy regime I show that surprisingly drastic effects can occur. When the energy of the incoming cluster is raised to a few eV/atom, the kinetic energy of the incoming cluster starts to affect the deposition. It will cause the cluster to entirely reform on impact. When the energy is raised to the range of keV's/cluster, the clusters start to penetrate the sample, fairly similar to conventional ion implantation. However, in dense targets the cluster ions may stick close to each other long enough to cause a significant enhancement of the heat spike in the material. Finally, I show that at kinetic energies around 1 MeV/cluster the cluster enhancement of the heat spike may lead to dramatic surface effects.

  18. Effects of high energy (MeV) ion beam irradiation on polyethylene terephthalate

    International Nuclear Information System (INIS)

    Singh, Nandlal; Sharma, Anita; Avasthi, D.K.

    2003-01-01

    Irradiation effects of 50 MeV Li 3+ ion beams in polyethylene terephthalate (PET) films were studied with respect to their structural and electrical properties by using Fourier transform infrared (FTIR) spectroscopy and ac electrical measurement in the frequency range: 50-100 kHz at different temperatures of 30-150 deg. C. It is found that ac resistivity of PET decreases as frequency increases. The temperature dependencies of dielectric loss tangent exhibit a peak (T g ) at 60 deg. C. The capacitance value of irradiated PET is almost temperature independent and ones increases with an increasing of lithium fluence. FTIR spectra show various bands related to C-H, C-O, C-O-C molecular bonds and groups which get modified or break down due to ion beam irradiation

  19. Optical Diode Effect at Spin-Wave Excitations of the Room-Temperature Multiferroic BiFeO_{3}.

    Science.gov (United States)

    Kézsmárki, I; Nagel, U; Bordács, S; Fishman, R S; Lee, J H; Yi, Hee Taek; Cheong, S-W; Rõõm, T

    2015-09-18

    Multiferroics permit the magnetic control of the electric polarization and the electric control of the magnetization. These static magnetoelectric (ME) effects are of enormous interest: The ability to read and write a magnetic state current-free by an electric voltage would provide a huge technological advantage. Dynamic or optical ME effects are equally interesting, because they give rise to unidirectional light propagation as recently observed in low-temperature multiferroics. This phenomenon, if realized at room temperature, would allow the development of optical diodes which transmit unpolarized light in one, but not in the opposite, direction. Here, we report strong unidirectional transmission in the room-temperature multiferroic BiFeO_{3} over the gigahertz-terahertz frequency range. The supporting theory attributes the observed unidirectional transmission to the spin-current-driven dynamic ME effect. These findings are an important step toward the realization of optical diodes, supplemented by the ability to switch the transmission direction with a magnetic or electric field.

  20. Activation of carbon monoxide by (Me3tpa)Rh and (Me3tpa)Ir

    NARCIS (Netherlands)

    Dzik, W.I.; Smits, J.M.M.; Reek, J.N.H.; de Bruin, B.

    2009-01-01

    Cationic iridium and rhodium carbonyl complexes supported with the tetradentate N-donor ligand Me(3)tpa (Me(3)tPa = N,N,N-tri(6-methyl-2-pyridylmethyl)amine) were synthesized. Their structures were investigated using X-ray diffraction, NMR, and IR, and their redox properties were probed using cyclic