WorldWideScience

Sample records for tem related techniques

  1. Recent advances in FIB-TEM specimen preparation techniques

    International Nuclear Information System (INIS)

    Li Jian; Malis, T.; Dionne, S.

    2006-01-01

    Preparing high-quality transmission electron microscopy (TEM) specimens is of paramount importance in TEM studies. The development of the focused ion beam (FIB) microscope has greatly enhanced TEM specimen preparation capabilities. In recent years, various FIB-TEM foil preparation techniques have been developed. However, the currently available techniques fail to produce TEM specimens from fragile and ultra-fine specimens such as fine fibers. In this paper, the conventional FIB-TEM specimen preparation techniques are reviewed, and their advantages and shortcomings are compared. In addition, a new technique suitable to prepare TEM samples from ultra-fine specimens is demonstrated

  2. Indications and techniques of transanal endoscopic microsurgery (TEMS).

    Science.gov (United States)

    Qi, Yanjie; Stoddard, David; Monson, John R T

    2011-08-01

    Transanal endoscopic microsurgery (TEMS) has recently reemerged as a valuable technique for the management of rectal neoplasms - both benign and malignant. Since the original description of this technique in the early 1980s, TEMS has emerged as the approach of choice for most benign rectal tumors because of the excellent views provided and superior dissection techniques possible when compared to traditional transanal excision. Many published reports demonstrate that the lowest rates of recurrence are associated with TEMS probably because of full-thickness excision with negative margins. Increasingly, TEMS is being applied to primary rectal cancer when used alone as a full-thickness excision alone or in combination with additional therapies, depending on tumor stage. There is now a significant evidence base to suggest that this approach should be considered as part of a multidisciplinary approach to rectal cancer. This paper describes indications and techniques for this technology.

  3. Preparation of TEM specimen by cross-section technique

    International Nuclear Information System (INIS)

    Hamada, Shozo

    1986-01-01

    Transmission electron microscopy (TEM) is applied to the direct observation of the depth dependent damage structure in ion-irradiated stainless steel by using the cross-section technique; obtaining the TEM specimen from a slice of the irradiated stainless steel with thick Ni plating. Here has been developed the specimen preparation method of cross-section technique without heat treatment, which was necessary in the conventional method to strengthen the bonding between Ni and stainless steel. Nickel plating with good bonding to stainless steel is enabled by the following manner. First, the irradiated stainless steel is immersed in the Wood's nickel solution at room temperature for 60s to activate the surface, followed by the stricking for 300s at a current density of 300 A/m 2 in the solution to make fine and homogeneous nucleation of Ni on the stainless steel. Then, the sample is plated with Ni in the Watt's nickel plating solution at 333 K with current density of 900 ∼ 1,000 A/m 2 . The TEM disc is obtained by mechanical slicing from the specimen with Ni plating of more than 3 mm thickness. Electropolishing is accomplished by using both Ballmann method and jet electropolishing to perforate the disc accurately at the aimed point for the observation of the damage structure. (author)

  4. Characterization of isolated polyamide thin films of RO and NF membranes using novel TEM techniques

    KAUST Repository

    Pacheco, Federico A.; Pinnau, Ingo; Reinhard, Martin; Leckie, James O.

    2010-01-01

    Achieving a better understanding of transport and rejection mechanisms in RO and NF membranes requires more detailed information of the nanostructure of polyamide thin films. This study reports on two novel transmission electron microscopy (TEM) techniques for characterizing polyamide nanostructure. The first technique produces cross-sectional images of isolated polyamide thin films by removing the polysulfone support from regular TEM cross-sections. In the second technique called " projected area" TEM (PA-TEM), isolated polyamide thin films are placed with their surface perpendicular to the electron beam. The resulting images capture the thickness, morphology and mass density of the entire thin film. In combination, these new techniques provide information on polyamide nanostructure that is not evident using conventional methods. For the commercial RO membrane ESPA3, the cross-sectional view of the isolated polyamide thin film shows a 30-60. nm thick base of nodular polyamide (presumably the separation barrier) that forms a relatively smooth interface with the polysulfone support. Above this, a more open structure of loose polyamide extends outward giving rise to the ridge-and-valley surface structure. In PA-TEM images, the ridges and valleys correspond to the dark and bright regions, respectively; the polyamide nodular base appears as round features forming an irregular honeycomb pattern throughout the images. Membrane cross-sections were prepared with a simple resin embedding protocol using the acrylic resin LR White. The protocol did not require dehydration steps, and was applicable to both dry and wet membrane samples. Artifacts that may be produced during sample preparation were also documented. © 2010 Elsevier B.V.

  5. Characterization of isolated polyamide thin films of RO and NF membranes using novel TEM techniques

    KAUST Repository

    Pacheco, Federico A.

    2010-08-15

    Achieving a better understanding of transport and rejection mechanisms in RO and NF membranes requires more detailed information of the nanostructure of polyamide thin films. This study reports on two novel transmission electron microscopy (TEM) techniques for characterizing polyamide nanostructure. The first technique produces cross-sectional images of isolated polyamide thin films by removing the polysulfone support from regular TEM cross-sections. In the second technique called " projected area" TEM (PA-TEM), isolated polyamide thin films are placed with their surface perpendicular to the electron beam. The resulting images capture the thickness, morphology and mass density of the entire thin film. In combination, these new techniques provide information on polyamide nanostructure that is not evident using conventional methods. For the commercial RO membrane ESPA3, the cross-sectional view of the isolated polyamide thin film shows a 30-60. nm thick base of nodular polyamide (presumably the separation barrier) that forms a relatively smooth interface with the polysulfone support. Above this, a more open structure of loose polyamide extends outward giving rise to the ridge-and-valley surface structure. In PA-TEM images, the ridges and valleys correspond to the dark and bright regions, respectively; the polyamide nodular base appears as round features forming an irregular honeycomb pattern throughout the images. Membrane cross-sections were prepared with a simple resin embedding protocol using the acrylic resin LR White. The protocol did not require dehydration steps, and was applicable to both dry and wet membrane samples. Artifacts that may be produced during sample preparation were also documented. © 2010 Elsevier B.V.

  6. Distortion of DNA Origami on Graphene Imaged with Advanced TEM Techniques.

    Science.gov (United States)

    Kabiri, Yoones; Ananth, Adithya N; van der Torre, Jaco; Katan, Allard; Hong, Jin-Yong; Malladi, Sairam; Kong, Jing; Zandbergen, Henny; Dekker, Cees

    2017-08-01

    While graphene may appear to be the ultimate support membrane for transmission electron microscopy (TEM) imaging of DNA nanostructures, very little is known if it poses an advantage over conventional carbon supports in terms of resolution and contrast. Microscopic investigations are carried out on DNA origami nanoplates that are supported onto freestanding graphene, using advanced TEM techniques, including a new dark-field technique that is recently developed in our lab. TEM images of stained and unstained DNA origami are presented with high contrast on both graphene and amorphous carbon membranes. On graphene, the images of the origami plates show severe unwanted distortions, where the rectangular shape of the nanoplates is significantly distorted. From a number of comparative control experiments, it is demonstrated that neither staining agents, nor screening ions, nor the level of electron-beam irradiation cause this distortion. Instead, it is suggested that origami nanoplates are distorted due to hydrophobic interaction of the DNA bases with graphene upon adsorption of the DNA origami nanoplates. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Novel in-situ lamella fabrication technique for in-situ TEM.

    Science.gov (United States)

    Canavan, Megan; Daly, Dermot; Rummel, Andreas; McCarthy, Eoin K; McAuley, Cathal; Nicolosi, Valeria

    2018-03-29

    In-situ transmission electron microscopy is rapidly emerging as the premier technique for characterising materials in a dynamic state on the atomic scale. The most important aspect of in-situ studies is specimen preparation. Specimens must be electron transparent and representative of the material in its operational state, amongst others. Here, a novel fabrication technique for the facile preparation of lamellae for in-situ transmission electron microscopy experimentation using focused ion beam milling is developed. This method involves the use of rotating microgrippers during the lift-out procedure, as opposed to the traditional micromanipulator needle and platinum weld. Using rotating grippers, and a unique adhesive substance, lamellae are mounted onto a MEMS device for in-situ TEM annealing experiments. We demonstrate how this technique can be used to avoid platinum deposition as well as minimising damage to the MEMS device during the thinning process. Our technique is both a cost effective and readily implementable alternative to the current generation of preparation methods for in-situ liquid, electrical, mechanical and thermal experimentation within the TEM as well as traditional cross-sectional lamella preparation. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. The Development of an In-Situ TEM Technique for Studying Corrosion Behavior as Applied to Zirconium-Based Alloys

    Science.gov (United States)

    Harlow, Wayne

    Zirconium-based alloys are a commonly used material for nuclear fuel rod cladding, due to its low neutron cross section and good corrosion properties. However, corrosion is still a limiting factor in fuel rod lifespan, which restricts burn up levels, and thus efficiency, that can be achieved. While long-term corrosion behavior has been studied through both reactor and autoclave samples, the oxide nucleation and growth behavior has not been extensively studied. This work develops a new technique to study the initial stages of corrosion in zirconium-based alloys and the microstructural effects on this process by developing an environmental cell system for the TEM. Nanoscale oxidation parameters are developed, as is a new FIB technique to support this method. Precession diffraction is used in conjunction with in-situ TEM to observe the initial stages of corrosion in these alloys, and oxide thickness is estimated using low-loss EELS. In addition, the stress stabilization of tetragonal ZrO 2 is explored in the context of sample preparation for TEM. It was found that in-situ environmental TEM using an environmental cell replicates the oxidation behavior observed in autoclaved samples in both oxide structure and phases. Utilizing this technique, it was shown that cracking of the oxide layer in zirconium-based alloys is related to oxide relaxation, and not thermal changes. The effect of secondary phase particles on oxidation behavior did not present significant results, however a new method for studying initial oxidation rates using low-loss EELS was developed.

  9. A TEM study of strained SiGe/Si and related heteroepitaxial structures

    International Nuclear Information System (INIS)

    Benedetti, Alessandro

    2002-01-01

    The role of SiGe/Si heterostructures and related materials has become increasingly important within the last few decades. In order to increase the scale of integration, however, devices with active elements not larger than few tens of nanometer have been recently introduced. There is, therefore, a strong need for an analytical technique capable of giving information about submicron-sized components. An investigation on a nanometre scale can be performed by the combination of a fully equipped Transmission Electron Microscope (TEM) with a Field Emission Gun (PEG) electron source, which enables one to use a wide range of analytical techniques with an electron probe as small as 0.5 nm. In this work, two different types of SiGe/Si-based devices were investigated. Strained-Si n-channel MOSFETs. The use of Strained-Si n-channel grown on SiGe should improve both carrier mobility and transconductance with respect to conventional MOSFETs. Materials analysed in this work showed an extremely high transconductance but a rather low mobility. In order to relate their microstructural properties to their electrical performance, as well as to improve the device design, a full quantitative and qualitative structural characterisation was performed. SiGe Multiple Quantum Wells (MQW) IR detectors Light detection is achieved by collecting the photogenerated carriers, injected from the SiGe QWs layers into the Si substrate. A key factor is the Ge profile across a single QW, since it governs the band structure and therefore the device performances. Four different TEM techniques were used to determine the Ge distribution across a single well, showing an overall good agreement among the results. The Ge profiles broadening, consistent with data available in literature, was successfully explained and theoretically predicted by the combined effect of Ge segregation and gas dwell times within the reactor. (author)

  10. Laser Based In Situ Techniques: Novel Methods for Generating Extreme Conditions in TEM Samples

    Energy Technology Data Exchange (ETDEWEB)

    Taheri, M; Lagrange, T; Reed, B; Armstrong, M; Campbell, G; DeHope, W; Kim, J; King, W; Masiel, D; Browning, N

    2008-02-25

    The Dynamic Transmission Electron Microscope (DTEM) is introduced as a novel tool for in situ processing of materials. Examples of various types of dynamic studies outline the advantages and differences of laser-based heating in the DTEM in comparison to conventional (resistive) heating in situ TEM methods. We demonstrate various unique capabilities of the drive laser, namely, in situ processing of nanoscale materials, rapid and high temperature phase transformations, and controlled thermal activation of materials. These experiments would otherwise be impossible without the use of the DTEM drive laser. Thus, the potential of the DTEM to as a new technique to process and characterize the growth of a myriad of micro and nanostructures is demonstrated.

  11. Development of non-intrusive monitoring techniques - ESDRED and TEM projects at Mont Terri and the Grimsel test site

    International Nuclear Information System (INIS)

    Breen, B.; Johnson, M.; Frieg, B.; Blechschmidt, I.; Manukyan, E.; Marelli, S.; Maurer, H.R.

    2008-01-01

    The EC Integrated Project, IP ESDRED (Engineering Studies and Demonstration of Repository Designs) was commissioned to establish a sound technical basis for demonstrating the safety of disposing of spent fuel and long-lived radioactive wastes in deep geological formations and to underpin the development of a common European view on the main issues related to the management and disposal of radioactive waste. The in situ development of non-intrusive monitoring techniques is included within the programme as an important component of the overall ESDRED programme. Monitoring will play an important role in providing information to the repository operator and to society in general and to support decision-making about if and when, to move from one phase to the next. The challenges, when constructing engineered barrier systems (EBS) to isolate the waste, is the ability to monitor the waste and the barriers, once isolated. Conventional monitoring systems depend upon wires or cable s to transfer information from the monitoring sensors outside the barriers. Monitoring sensors also have a limited lifetime and new sensors cannot be emplaced without disturbing the barrier. The development of non-intrusive monitoring systems which do not rely upon 'hard-wired' connection, thus providing the opportunity for continued monitoring after isolation. The ESDRED partners developed a programme utilising cross-hole seismic tomography to monitor an experimental demonstration by Nagra at Mont Terri Underground Research Laboratory (URL). The work programme includes PhD studies to conduct full seismic waveform analysis and to develop algorithms to address natural anisotropy in the Opalinus clay at Mont Terri. Following on from the ESDRED developments, some of ESDRED partner organisations identified a further opportunity for developing in situ monitoring techniques utilising the construction and testing programme of a low pH shotcrete plug being constructed in granite at the Grimsel Test Site

  12. Multiple sectioning and perforation techniques for TEM sub-surface studies

    International Nuclear Information System (INIS)

    Lee, E.H.; Rowcliffe, A.F.

    1978-01-01

    Techniques for preparing multiple electron transparent regions at several depth levels below the surface of a metal disk specimen are described. These techniques are relatively rapid and find application in many areas involving surface studies. Examples are shown of multiple thin areas produced at intervals of approximately 200 nm below the original surface of a stainless steel bombarded with 4 MeV Ni +2 ions for void swelling studies

  13. Study of InGaN/GaN quantum dot systems by TEM techniques and photoluminescence spectroscopy

    International Nuclear Information System (INIS)

    Kashtiban, R J; Bangert, U; Harvey, A J; Sherliker, B; Halsall, M P

    2010-01-01

    InGaN/GaN multilayer quantum dot structures produced by MOCVD techniques on c-plane sapphire were studied by transmission electron microscopy (TEM) and photoluminescence (PL) techniques. Indium fluctuations ranging from 1-4 nm were observed with both energy filtered TEM (EFTEM) and high angle annular dark field (HAADF) scanning TEM. The existence of V-shaped defects with nucleation centres at the termination of threading dislocation were observed in HAADF images. There was also evidence of the formation of large quantum dots at low densities from lattice HRTEM images. This was further confirmed by PL measurements through the observation of a single sharp line at low power with the typical saturation behaviour at higher power excitation.

  14. In Situ TEM Multi-Beam Ion Irradiation as a Technique for Elucidating Synergistic Radiation Effects

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, Caitlin; Bufford, Daniel; Muntifering, Brittany; Senor, David; Steckbeck, Mackenzie; Davis, Justin; Doyle, Barney; Buller, Daniel; Hattar, Khalid

    2017-09-29

    Materials designed for nuclear reactors undergo microstructural changes resulting from a combination of several environmental factors, including neutron irradiation damage, gas accumulation and elevated temperatures. Typical ion beam irradiation experiments designed for simulating a neutron irradiation environment involve irradiating the sample with a single ion beam and subsequent characterization of the resulting microstructure, often by transmission electron microscopy (TEM). This method does not allow for examination of microstructural effects due to simultaneous gas accumulation and displacement cascade damage, which occurs in a reactor. Sandia’s in situ ion irradiation TEM (I3TEM) offers the unique ability to observe microstructural changes due to irradiation damage caused by concurrent multi-beam ion irradiation in real time. This allows for time-dependent microstructure analysis. A plethora of additional in situ stages can be coupled with these experiments, e.g., for more accurately simulating defect kinetics at elevated reactor temperatures. This work outlines experiments showing synergistic effects in Au using in situ ion irradiation with various combinations of helium, deuterium and Au ions, as well as some initial work on materials utilized in tritium-producing burnable absorber rods (TPBARs): zirconium alloys and LiAlO2.

  15. In Situ TEM Multi-Beam Ion Irradiation as a Technique for Elucidating Synergistic Radiation Effects

    Directory of Open Access Journals (Sweden)

    Caitlin Anne Taylor

    2017-09-01

    Full Text Available Materials designed for nuclear reactors undergo microstructural changes resulting from a combination of several environmental factors, including neutron irradiation damage, gas accumulation and elevated temperatures. Typical ion beam irradiation experiments designed for simulating a neutron irradiation environment involve irradiating the sample with a single ion beam and subsequent characterization of the resulting microstructure, often by transmission electron microscopy (TEM. This method does not allow for examination of microstructural effects due to simultaneous gas accumulation and displacement cascade damage, which occurs in a reactor. Sandia’s in situ ion irradiation TEM (I3TEM offers the unique ability to observe microstructural changes due to irradiation damage caused by concurrent multi-beam ion irradiation in real time. This allows for time-dependent microstructure analysis. A plethora of additional in situ stages can be coupled with these experiments, e.g., for more accurately simulating defect kinetics at elevated reactor temperatures. This work outlines experiments showing synergistic effects in Au using in situ ion irradiation with various combinations of helium, deuterium and Au ions, as well as some initial work on materials utilized in tritium-producing burnable absorber rods (TPBARs: zirconium alloys and LiAlO2.

  16. Comprehensive analysis of TEM methods for LiFePO4/FePO4 phase mapping: spectroscopic techniques (EFTEM, STEM-EELS) and STEM diffraction techniques (ACOM-TEM).

    Science.gov (United States)

    Mu, X; Kobler, A; Wang, D; Chakravadhanula, V S K; Schlabach, S; Szabó, D V; Norby, P; Kübel, C

    2016-11-01

    Transmission electron microscopy (TEM) has been used intensively in investigating battery materials, e.g. to obtain phase maps of partially (dis)charged (lithium) iron phosphate (LFP/FP), which is one of the most promising cathode material for next generation lithium ion (Li-ion) batteries. Due to the weak interaction between Li atoms and fast electrons, mapping of the Li distribution is not straightforward. In this work, we revisited the issue of TEM measurements of Li distribution maps for LFP/FP. Different TEM techniques, including spectroscopic techniques (energy filtered (EF)TEM in the energy range from low-loss to core-loss) and a STEM diffraction technique (automated crystal orientation mapping (ACOM)), were applied to map the lithiation of the same location in the same sample. This enabled a direct comparison of the results. The maps obtained by all methods showed excellent agreement with each other. Because of the strong difference in the imaging mechanisms, it proves the reliability of both the spectroscopic and STEM diffraction phase mapping. A comprehensive comparison of all methods is given in terms of information content, dose level, acquisition time and signal quality. The latter three are crucial for the design of in-situ experiments with beam sensitive Li-ion battery materials. Furthermore, we demonstrated the power of STEM diffraction (ACOM-STEM) providing additional crystallographic information, which can be analyzed to gain a deeper understanding of the LFP/FP interface properties such as statistical information on phase boundary orientation and misorientation between domains. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Microstructural study of codeposited pentacene:perfluoropentacene grown on KCl by TEM techniques

    Science.gov (United States)

    Félix, Rocío; Breuer, Tobias; Witte, Gregor; Volz, Kerstin; Gries, Katharina I.

    2017-08-01

    Transmission electron microscopy techniques have been used as a research tool to derive information on structure and orientation of organic semiconductor blends. Within this work, we have studied the structure and morphology of pentacene (PEN, C22H14) and perfluoropentacene (PFP, C22F14) blends grown with [2:1] and [1:2] mixing ratios on KCl substrates. The [2:1] mixture exhibits a uniform layer on the substrate with domains that are rotated in-plane by 90° towards each other. Electron diffraction experiments revealed that these domains are formed by a crystalline mixed phase (consisting of PEN and PFP) and a PEN phase in excess whose lattice parameters are rather similar. By contrast, in the [1:2] blend, two different arrangements were found. The majority of the sample exhibits some spicular fibers on a background layer lying on top of the KCl substrate. The microstructural characterization revealed that these fibers consist of pure PFP in excess while the background layer is formed by the mixed phase. The other arrangement, which is present to a lesser extent, consists of a PFP film that is in direct contact with the KCl substrate. Using electron diffraction experiments, the orientation of the different phases with respect to each other and in some cases relative to the KCl substrate has been determined.

  18. Recombination-related properties of a-screw dislocations in GaN: A combined CL, EBIC, TEM study

    Energy Technology Data Exchange (ETDEWEB)

    Medvedev, O. S., E-mail: o.s.medvedev@spbu.ru; Mikhailovskii, V. Yu. [V.A. Fok Institute of Physics, St. Petersburg State University (Russian Federation); IRC for Nanotechnology, Research Park, St.-Petersburg State University (Russian Federation); Vyvenko, O. F.; Bondarenko, A. S.; Ubyivovk, E. V. [V.A. Fok Institute of Physics, St. Petersburg State University (Russian Federation); Peretzki, P.; Seibt, M. [IV. Physikalisches Institut Georg-August Universität Göttingen (Germany)

    2016-06-17

    Cathodoluminescence (CL), electron beam current (EBIC) and transmission electron microscopy (TEM) techniques have been applied to investigate recombination properties and structure of freshly introduced dislocations in low-ohmic GaN crystals. It was confirmed that the only a-screw dislocations exhibited an intense characteristic dislocation-related luminescence (DRL) which persisted up to room temperature and was red-shifted by about 0.3 eV with respect to the band gap energy not only in HVPE but also in MOCVD grown samples. EBIC contrast of the dislocations was found to be temperature independent indicating that the dislocation-related recombination level is situated below 200 meV with respect of conduction band minimum. With the increasing of the magnification of the dislocation TEM cross-sectional images they were found to disappear, probably, due to the recombination enhanced dislocation glide (REDG) under electron beam exposure which was immediately observed in CL investigations on a large scale. The stacking fault ribbon in the core of dissociated a-screw dislocation which form a quantum well for electrons was proposed to play an important role both in DRL spectrum formation and in REDG.

  19. Microscopic studies on Y2Ba4Cu7O15-δ by use of TEM and NQR techniques

    International Nuclear Information System (INIS)

    Kato, Masaki; Nakanishi, Makoto; Yoshimura, Kazuyoshi; Kosuge, Koji; Miyano, Toshio; Kakihana, Masato

    1998-01-01

    Y 2 Ba 4 Cu 7 O 15-δ compounds were characterized by microscopic investigation using TEM and NQR techniques. The authors synthesized Y247 compounds by two kinds of preparation methods: the conventional solid-state reaction (sample A) and the polymerized-complex method (sample B). The value of T c for sample A was found o be 65 K and that for sample B as 93 K by ac-χ measurements. As a result of TEM experiments, stacking faults along the c axis were observed more frequently in sample B than in sample A. These stacking faults resulted in microdomains containing pure Y123 or Y124 thin blocks of several unit cells. NQR experiments revealed that the microscopic environment of Cu(2) sites in sample A differed from either of those in the Y123 and Y124 compounds. NQR frequency values (ν Q ) of Cu(2) sites agreed well with those calculated by the point charge model applied for the Y247 structure. The spectra of Cu(2) sites in sample B could be regarded, however, as a combination of those of pure Y123, Y124, and also Y247 compounds. This fact was coincident with the result of TEM experiments. The authors concluded that the superconductivity of Y247 with higher T c originates from the thin block of Y123

  20. Using the in situ lift-out technique to prepare TEM specimens on a single-beam FIB instrument

    International Nuclear Information System (INIS)

    Lekstrom, M; McLachlan, M A; Husain, S; McComb, D W; Shollock, B A

    2008-01-01

    Transmission electron microscope (TEM) specimens are today routinely prepared using focussed ion beam (FIB) instruments. Specifically, the lift-out method has become an increasingly popular technique and involves removing thin cross-sections from site-specific locations and transferring them to a TEM grid. This lift-out process can either be performed ex situ or in situ. The latter is mainly carried out on combined dual-beam FIB and scanning electron microscope (SEM) systems whereas conventional single-beam instruments often are limited to the traditional ex situ method. It is nevertheless desirable to enhance the capabilities of existing single-beam instruments to allow for in situ lift-out preparation to be performed since this technique offers a number of advantages over the older ex situ method. A single-beam FIB instrument was therefore modified to incorporate an in situ micromanipulator fitted with a tungsten needle, which can be attached to a cut-out FIB section using ion beam induced platinum deposition. This article addresses the issues of using an ion beam to monitor the in situ manipulation process as well as approaches that can be used to create stronger platinum welds between two objects, and finally, views on how to limit the extent of ion beam damage to the specimen surface.

  1. Evaluation of strain caused by coherent precipitates in an Al alloy using TEM techniques

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez-Rivera, J.L., E-mail: jose.hernandez@cimav.edu.mx [Centro de Investigacion en Materiales Avanzados (CIMAV), Laboratorio Nacional de Nanotecnologia, Miguel de Cervantes 120, Z.C. 31109, Chihuahua (Mexico); Universidad del Valle de Mexico, Robles 600, Fraccionamiento Jacarandas, Z. C. 78220, San Luis Potosi (Mexico); Rivera, J.J. Cruz; Garay-Reyes, C.G.; Azpeitia, M. Ramos; Zuniga-Alonso, I. [Facultad de Ingenieria-Instituto de Metalurgia, Universidad Autonoma de San Luis Potosi, Sierra Leona 550, Lomas 2a seccion, Z.C. 78210, San Luis Potosi (Mexico); Martinez-Sanchez, R. [Centro de Investigacion en Materiales Avanzados (CIMAV), Laboratorio Nacional de Nanotecnologia, Miguel de Cervantes 120, Z.C. 31109, Chihuahua (Mexico)

    2012-11-15

    Elastic strains, caused by GP zones in an aged Al alloy, were determined quantitatively using two techniques: Dark Field In-line Holography (DFH) and High Resolution Transmission Electron Microscopy-Geometric Phase Analysis (HRTEM-GPA). The results obtained by both techniques showed that the elastic strain was not uniform along the precipitate-matrix interface. In some areas, it was found that strain had negligible value and this was attributed to the loss of coherence between the lattices. It is suggested that a possible explanation for this fact could be a variation in the 'vacancies pump mechanism' kinetics. To obtain a better interpretation of the experimental deformation maps, a reference GP precipitate-matrix structure was built using QSTEM software. The main advantages of DFH over HRTEM-GPA were a bigger field of view and low electron dose requirements without spatial resolution loss. Another difference found was that crystalline defects such as dislocations were evidenced by HRTEM-GPA in contrast to the result obtained by DFH. However, strain measurements were affected by mask size effect in the former. - Highlights: Black-Right-Pointing-Pointer Strain around GP precipitates was not uniform and was in a more relaxed state. Black-Right-Pointing-Pointer Strain values determined by HRTEM had more artifacts compared with holography ones. Black-Right-Pointing-Pointer Strain distribution was attributed to differences in the release of vacancies. Black-Right-Pointing-Pointer Holography showed important advantages over HRTEM regarding field of view mainly.

  2. Evaluation of strain caused by coherent precipitates in an Al alloy using TEM techniques

    International Nuclear Information System (INIS)

    Hernández-Rivera, J.L.; Rivera, J.J. Cruz; Garay-Reyes, C.G.; Azpeitia, M. Ramos; Zúñiga-Alonso, I.; Martínez-Sánchez, R.

    2012-01-01

    Elastic strains, caused by GP zones in an aged Al alloy, were determined quantitatively using two techniques: Dark Field In-line Holography (DFH) and High Resolution Transmission Electron Microscopy-Geometric Phase Analysis (HRTEM-GPA). The results obtained by both techniques showed that the elastic strain was not uniform along the precipitate–matrix interface. In some areas, it was found that strain had negligible value and this was attributed to the loss of coherence between the lattices. It is suggested that a possible explanation for this fact could be a variation in the “vacancies pump mechanism” kinetics. To obtain a better interpretation of the experimental deformation maps, a reference GP precipitate–matrix structure was built using QSTEM software. The main advantages of DFH over HRTEM-GPA were a bigger field of view and low electron dose requirements without spatial resolution loss. Another difference found was that crystalline defects such as dislocations were evidenced by HRTEM-GPA in contrast to the result obtained by DFH. However, strain measurements were affected by mask size effect in the former. - Highlights: ► Strain around GP precipitates was not uniform and was in a more relaxed state. ► Strain values determined by HRTEM had more artifacts compared with holography ones. ► Strain distribution was attributed to differences in the release of vacancies. ► Holography showed important advantages over HRTEM regarding field of view mainly.

  3. Problems at the Leading Edge of Space Weathering as Revealed by TEM Combined with Surface Science Techniques

    Science.gov (United States)

    Christoffersen, R.; Dukes, C. A.; Keller, L. P.; Rahman, Z.; Baragiola, R. A.

    2015-01-01

    Both transmission electron micros-copy (TEM) and surface analysis techniques such as X-ray photoelectron spectroscopy (XPS) were instrumen-tal in making the first characterizations of material generated by space weathering in lunar samples [1,2]. Without them, the nature of nanophase metallic Fe (npFe0) correlated with the surface of lunar regolith grains would have taken much longer to become rec-ognized and understood. Our groups at JSC and UVa have been using both techniques in a cross-correlated way to investigate how the solar wind contributes to space weathering [e.g., 3]. These efforts have identified a number of ongoing problems and knowledge gaps. Key insights made by UVa group leader Raul Barag-iola during this work are gratefully remembered.

  4. Transanal endoscopic micro-surgery (TEMS) for the management of large or sessile rectal adenomas: a review of the technique and indications.

    Science.gov (United States)

    Papagrigoriadis, Savvas

    2006-05-04

    In this review article the surgical technique of Transanal Endoscopic Microsurgery (TEMS) is examined. A number of techniques have been used to treat adenomas of the rectum. The treatment of large adenomas which occupy a large surface of the rectal lumen or adenomas which are flat and grow in a "carpet-like" fashion is particularly challenging. Major rectal surgery carries a risk of morbidity and mortality, particularly in elderly and unfit patients. Although local excision with transanal resection (TAR) and the Kraske sacral operation have been used in the past, during the last twenty years TEMS has become the method of choice for those lesions. TEMS is efficient and minimally invasive. The technique allows the patient to recover rapidly and the incidence of complications is much lower than that of major surgery. In case of recurrence the option of repeat TEMS or major surgery remain available. TEMS has been slow to gain popularity mainly for reasons of cost and steep learning curve but it is now an established procedure and a valuable therapeutic option which is particularly useful for elderly and unfit patients. Gastroenterologists should be aware of the nature and indications of TEMS in order to advise and refer selected patients with rectal adenomas accordingly.

  5. Comprehensive analysis of TEM methods for LiFePO4/FePO4 phase mapping: spectroscopic techniques (EFTEM, STEM-EELS) and STEM diffraction techniques (ACOM-TEM)

    DEFF Research Database (Denmark)

    Mu, X.; Kobler, A.; Wang, D.

    2016-01-01

    Transmission electron microscopy (TEM) has been used intensively in investigating battery materials, e.g. to obtain phase maps of partially (dis)charged (lithium) iron phosphate (LFP/FP), which is one of the most promising cathode material for next generation lithium ion (Li-ion) batteries. Due t...

  6. Variations in fixation techniques for field emission SEM and TEM of zebrafish (Branchydanio rerio) embryo inner and outer membranes

    NARCIS (Netherlands)

    Kalicharan, D; Jongebloed, WL; Rawson, DM; Zhang, TT

    1998-01-01

    The morphology of embryos of the fresh water teleost, Brachydania rerio (zebrafish), was examined in a parallel FE-SEM/TEM study, after various pre- and post-fixation regimes. Special attention was paid to the chorion, the contents of the peri-vitelline space, the plasma membrane, the syncytial

  7. Transanal endoscopic micro-surgery (TEMS) for the management of large or sessile rectal adenomas: a review of the technique and indications

    OpenAIRE

    Papagrigoriadis, Savvas

    2006-01-01

    In this review article the surgical technique of Transanal Endoscopic Microsurgery (TEMS) is examined. A number of techniques have been used to treat adenomas of the rectum. The treatment of large adenomas which occupy a large surface of the rectal lumen or adenomas which are flat and grow in a "carpet-like" fashion is particularly challenging. Major rectal surgery carries a risk of morbidity and mortality, particularly in elderly and unfit patients. Although local excision with transanal res...

  8. Radioimmunoassay and other related techniques

    International Nuclear Information System (INIS)

    Zarkawi, Moutaz

    1993-04-01

    The article reviews principles, requirements and reliability criteria of radioimmunoassay (RIA). Since basic reactions involved in RIA and related techniques are derived from reactions which take place in the immune system (IS) of humans and animals, the IS and the way it works will be described. In addition to RIA which involves the use of isotopes as tracers (labels), other non-radioisotopic and recent immunoassay techniques i.e. enzyme-linked immunosorbent assay (ELISA), chemiluminescence immunoassay (CLIA) and fluoroimmunoassay (FIA) will be dealt with. Some important and related terms will be defined and explained. (author). 59 refs., 4 figs

  9. Preparation and observation of an artifact-free Ge2Sb2Te5 TEM specimen by the small angle cleavage technique

    International Nuclear Information System (INIS)

    Kim, M.S.; Kim, H.G.

    2006-01-01

    The amorphous Ge 2 Sb 2 Te 5 thin film for the application to the non-volatile memory device was prepared by the pulsed laser deposition on a SiO2/Si substrate. The amorphous Ge 2 Sb 2 Te 5 which has the T C around 150 deg. C is readily crystallized when exposed to a comparable heat such as the Ar beam irradiation during the conventional ion milling process. Retaining its amorphous initial phase is important in order to precisely observe and understand the crystallization behaviour whether it be the sample for a pure materialistic research or applied into the device. To avoid such deterioration of the film's amorphous nature, the complete mechanical TEM specimen preparation which is called the small angle cleavage technique (SACT) was adopted to show thermally undisturbed, an artifact-free amorphous Ge 2 Sb 2 Te 5 TEM specimen. The two distinctive amorphous and crystalline phases has been observed by the HRTEM study

  10. Investigating the Mechanical Behavior and Deformation Mechanisms of Ultrafinegrained Metal Films Using Ex-situ and In-situ TEM Techniques

    Science.gov (United States)

    Izadi, Ehsan

    Nanocrystalline (NC) and Ultrafine-grained (UFG) metal films exhibit a wide range of enhanced mechanical properties compared to their coarse-grained counterparts. These properties, such as very high strength, primarily arise from the change in the underlying deformation mechanisms. Experimental and simulation studies have shown that because of the small grain size, conventional dislocation plasticity is curtailed in these materials and grain boundary mediated mechanisms become more important. Although the deformation behavior and the underlying mechanisms in these materials have been investigated in depth, relatively little attention has been focused on the inhomogeneous nature of their microstructure (particularly originating from the texture of the film) and its influence on their macroscopic response. Furthermore, the rate dependency of mechanical response in NC/UFG metal films with different textures has not been systematically investigated. The objectives of this dissertation are two-fold. The first objective is to carry out a systematic investigation of the mechanical behavior of NC/UFG thin films with different textures under different loading rates. This includes a novel approach to study the effect of texture-induced plastic anisotropy on mechanical behavior of the films. Efforts are made to correlate the behavior of UFG metal films and the underlying deformation mechanisms. The second objective is to understand the deformation mechanisms of UFG aluminum films using in-situ transmission electron microscopy (TEM) experiments with Automated Crystal Orientation Mapping. This technique enables us to investigate grain rotations in UFG Al films and to monitor the microstructural changes in these films during deformation, thereby revealing detailed information about the deformation mechanisms prevalent in UFG metal films.

  11. Texture evolution and microstructural changes during solid-state dewetting: A correlative study by complementary in situ TEM techniques

    International Nuclear Information System (INIS)

    Niekiel, Florian; Kraschewski, Simon M.; Schweizer, Peter; Butz, Benjamin; Spiecker, Erdmann

    2016-01-01

    The transition of a thin film into an energetically favorable set of particles at temperatures below the melting point of the bulk material is known as solid-state dewetting. In this work the dewetting behavior of 16 nm thick discontinuous Au thin films on amorphous silicon nitride membranes is quantitatively studied by complementary in situ transmission electron microscopy techniques taking advantage of the unique capabilities of a chip-based heating system. The combination of dedicated imaging and diffraction techniques is used to investigate the interplay of grain growth and texture evolution with the process of dewetting. The results show an initial coarsening of the microstructure preceding the other processes. Texture evolution is highly correlated to material retraction and agglomeration during the following dewetting process. In-plane grain rotation has been observed, acting as an additional mechanism for orientation changes. From a methodological perspective this work demonstrates the capabilities of today’s transmission electron microscopy in combination with state-of-the-art in situ instrumentation. In particular the combination of complementary information from different dedicated techniques in one and the same setup is demonstrated to be highly beneficial.

  12. Characterization of low alloy ferritic steel–Ni base alloy dissimilar metal weld interface by SPM techniques, SEM/EDS, TEM/EDS and SVET

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Siyan; Ding, Jie; Ming, Hongliang; Zhang, Zhiming; Wang, Jianqiu, E-mail: wangjianqiu@imr.ac.cn

    2015-02-15

    The interface region of welded A508–Alloy 52 M is characterized by scanning probe microscope (SPM) techniques, scanning electron microscopy (SEM)/energy dispersive spectroscopy (EDS), transmission electron microscopy (TEM)/Energy Dispersive Spectroscopy (EDS) and scanning vibrate electrode technique (SVET). The regions along the welded A508–Alloy 52 M interface can be categorized into two types according to their different microstructures. In the type-I interface region, A508 and Alloy 52 M are separated by the fusion boundary, while in the type-II interface region, A508 and Alloy 52 M are separated by a martensite zone. A508, martensite zone and grain boundaries in Alloy 52 M are ferromagnetic while the Alloy 52 M matrix is paramagnetic. The Volta potentials measured by scanning Kelvin probe force microscopy (SKPFM) of A508, martensite zone and Alloy 52 M follow the order: V{sub 52} {sub M} > V{sub A508} > V{sub martensite}. The corrosion behavior of A508–Alloy 52 M interface region is galvanic corrosion, in which Alloy 52 M is cathode while A508 is anode. The martensite dissolves faster than Alloy 52 M, but slower than A508 in the test solution. - Highlights: • The A508–Alloy 52 M interface regions can be categorized into two types. • The chromium depleted region is observed along the Alloy 52 M grain boundary. • The Alloy 52 M grain boundaries which are close to the interface are ferromagnetic. • Martensite zone has lower Volta potential but higher corrosion resistance than A508.

  13. Age-related liquefaction of the human vitreous body : LM and TEM evaluation of the role of proteoglycans and collagen

    NARCIS (Netherlands)

    Los, Leonoor I.; van der Worp, Roelofje J; van Luyn, Marja J. A.; Hooymans, Johanna M. M.

    PURPOSE. To evaluate morphologic aspects of age-related liquefaction of the human vitreous body by fight and electron microscopy to provide a basis from which future studies directed at the pathogenesis of this phenomenon can be undertaken. The study focuses on changes in fibrillar Collagen and

  14. Is the TEM obsolescent?

    International Nuclear Information System (INIS)

    Williams, D.B.

    2002-01-01

    Full text: The TEM has undergone many revolutions since its invention 70 years ago, but is now a very mature instrument. The major functions of imaging, diffraction and analysis were invented decades ago. Much of the instrument development in the last 20 years has come in peripheral improvements such as ease of operation and computer control which, nevertheless, have made no substantial differences to basic operational methods. The TEM remains a predominantly manual instrument, still providing analog viewing and recording, well into the digital age. Indeed any operator of a Siemens Elmiskop 1 TEM from the 1950s would be more than skilled enough to operate a modern FEG TEM, with little more than a few minutes of training. It is arguable that no other cutting-edge scientific instrument is so basically unchanged in its method of operation over the last five decades, as the TEM. This state of affairs is a recipe for obsolescence. Students today are not interested in mastering the complexities of balancing potentiometers (which are still necessary for good centered dark-field operation) or manipulating sets of tilt controls to move from to , while fighting to maintain eucentricity and a recognizable image on the screen at 200 kX. Students are already masters of the mouse, keyboard or joystick and expect information to be generated, stored, processed and analyzed rapidly and efficiently under full computer control. We need to provide today's students with an instrument to challenge their skills, not those of their parents. There is nothing preventing the creation of a TEM that is under full computer control, except perhaps the notion that the TEM is an instrument worthy of mastery per se, rather than being simply a tool for the characterization of materials. In contrast, the SEM has never been seen as a 'real' electron microscope and consequently has found its way into many more research, education and commercial operations than the TEM. The SEM has also evolved

  15. Cellular imaging electron tomography and related techniques

    CERN Document Server

    2018-01-01

    This book highlights important techniques for cellular imaging and covers the basics and applications of electron tomography and related techniques. In addition, it considers practical aspects and broadens the technological focus by incorporating techniques that are only now becoming accessible (e.g. block face imaging).  The first part of the book describes the electron microscopy 3D technique available to scientists around the world, allowing them to characterize organelles, cells and tissues. The major emphasis is on new technologies like scanning transmission electron microscopy (STEM) tomography, though the book also reviews some of the more proven technologies like electron tomography. In turn, the second part is dedicated to the reconstruction of data sets, signal improvement and interpretation.

  16. Constrained principal component analysis and related techniques

    CERN Document Server

    Takane, Yoshio

    2013-01-01

    In multivariate data analysis, regression techniques predict one set of variables from another while principal component analysis (PCA) finds a subspace of minimal dimensionality that captures the largest variability in the data. How can regression analysis and PCA be combined in a beneficial way? Why and when is it a good idea to combine them? What kind of benefits are we getting from them? Addressing these questions, Constrained Principal Component Analysis and Related Techniques shows how constrained PCA (CPCA) offers a unified framework for these approaches.The book begins with four concre

  17. Conference on Bootstrapping and Related Techniques

    CERN Document Server

    Rothe, Günter; Sendler, Wolfgang

    1992-01-01

    This book contains 30 selected, refereed papers from an in- ternational conference on bootstrapping and related techni- ques held in Trier 1990. Thepurpose of the book is to in- form about recent research in the area of bootstrap, jack- knife and Monte Carlo Tests. Addressing the novice and the expert it covers as well theoretical as practical aspects of these statistical techniques. Potential users in different disciplines as biometry, epidemiology, computer science, economics and sociology but also theoretical researchers s- hould consult the book to be informed on the state of the art in this area.

  18. Some special techniques related to XAFS

    International Nuclear Information System (INIS)

    Ma Lidun; Kang Litao; Shi Guoshun

    2001-01-01

    Some special techniques related to XAFS are simply introduced. Atomic XAFS is produced by the photoelectron scattering by the outer valance electrons of the absorption atoms, which can be used for studying the outer electron structure of the absorption atoms and the relationship between electron structure and the local structure. NEXAFS-STXM is an image technique by the combination of NEXAFS and STXM. The image is produced by the difference of the absorption of the different matters consisted by the same elements in the range of NEXAFS. In addition, NEXAFS-STXM can quantitatively map the organic and inorganic components of biological tissue. Photoacoustic XAFS is obtained by the measurements of the photoacoustic signal on the both sides of the absorption edge. The film thickness can be measured by the phase delay of the photoacoustic signal. DAFS technique is a complex of XAFS and XRD. The local structure of the atom with special site and appointed valence can be determined by DAFS. Furthermore, the XAFS can be complexed with X-ray Raman scattering, XRD, XPS and FTIR for structural studies, respectively

  19. Characterization of duplex stainless steels by TEM [transmission electron microscopy], SANS [small-angle neutron scattering], and APFIM [atom-probe field ion microscopy] techniques

    International Nuclear Information System (INIS)

    Chung, H.M.; Chopra, O.K.

    1987-06-01

    Results are presented of complementary characterization of aged duplex stainless steels by advanced metallographic techniques, including transmission and high-voltage electron microscopies; small-angle neutron scattering; and atom-probe field ion microscopy. On the basis of the characterization, the mechanisms of aging embrittlement have been shown to be associated with the precipitation of Ni- and Si-rich G phase and Cr-rich α' in the ferrite, and M 23 C 6 carbides on the austenite-ferrite phase boundaries. 19 refs., 19 figs., 1 tab

  20. In situ TEM electromechanical testing of nanowires and nanotubes.

    Science.gov (United States)

    Espinosa, Horacio D; Bernal, Rodrigo A; Filleter, Tobin

    2012-11-05

    The emergence of one-dimensional nanostructures as fundamental constituents of advanced materials and next-generation electronic and electromechanical devices has increased the need for their atomic-scale characterization. Given its spatial and temporal resolution, coupled with analytical capabilities, transmission electron microscopy (TEM) has been the technique of choice in performing atomic structure and defect characterization. A number of approaches have been recently developed to combine these capabilities with in-situ mechanical deformation and electrical characterization in the emerging field of in-situ TEM electromechanical testing. This has enabled researchers to establish unambiguous synthesis-structure-property relations for one-dimensional nanostructures. In this article, the development and latest advances of several in-situ TEM techniques to carry out mechanical and electromechanical testing of nanowires and nanotubes are reviewed. Through discussion of specific examples, it is shown how the merging of several microsystems and TEM has led to significant insights into the behavior of nanowires and nanotubes, underscoring the significant role in-situ techniques play in the development of novel nanoscale systems and materials. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Stereoscopic methods in TEM

    International Nuclear Information System (INIS)

    Thomas, L.E.

    1975-07-01

    Stereoscopic methods used in TEM are reviewed. The use of stereoscopy to characterize three-dimensional structures observed by TEM has become widespread since the introduction of instruments operating at 1 MV. In its emphasis on whole structures and thick specimens this approach differs significantly from conventional methods of microstructural analysis based on three-dimensional image reconstruction from a number of thin-section views. The great advantage of stereo derives from the ability to directly perceive and measure structures in three-dimensions by capitalizing on the unsurpassed human ability for stereoscopic matching of corresponding details on picture pairs showing the same features from different viewpoints. At this time, stereo methods are aimed mainly at structural understanding at the level of dislocations, precipitates, and irradiation-induced point-defect clusters in crystal and on the cellular irradiation-induced point-defect clusters in crystal and on the cellular level of biological specimens. 3-d reconstruction methods have concentrated on the molecular level where image resolution requirements dictate the use of very thin specimens. One recent application of three-dimensional coordinate measurements is a system developed for analyzing depth variations in the numbers, sizes and total volumes of voids produced near the surfaces of metal specimens during energetic ion bombardment. This system was used to correlate the void volumes at each depth along the ion range with the number of atomic displacements produced at that depth, thereby unfolding the entire swelling versus dose relationship from a single stereo view. A later version of this system incorporating computer-controlled stereo display capabilities is now being built

  2. A study on microstructures and extended defects in Ni- and Co-base superalloys. Development and application of advanced TEM techniques

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, Julian

    2016-04-21

    To improve the efficiency of stationary gas turbines and air craft jet engines, it is crucial to increase the maximum temperature capabilities of single crystalline superalloys by appropriate alloy design and microstructure tuning. The mechanical properties of superalloys are largely influenced by the physical constitution of the microstructure. To develop a better understanding of fundamental aspects of creep deformation, like the stress states, defect structures and other degradation processes, it is necessary to employ scale-bridging characterization. In the present work, Ni- and Co-based superalloys are investigated by a series of advanced transmission electron microscopy techniques and by the application of specifically developed characterization methods to identify dominating processes on atomic scale and hence to make a direct correlation to the macroscopic creep behavior. For instance, the misfit between γ and γ' in the initial microstructure is of great importance, since it strongly influences the rafting process and the interfacial dislocation network. To address the stress state, on the one hand misfit measurements in undeformed samples are conducted and are directly compared to finite-element simulations. On the other hand, deformed samples are investigated to assess the influence of an initial rafting process and the formation of an interface dislocation network. For this, characterization methods are used which are based on the evaluation of atomically resolved images and on electron diffraction. Moreover, the temperature dependency of the misfit and of the microstructure stability is specifically investigated for different Co-base alloys in in situ heating experiments. The characterization of defect structures in Ni-base superalloys after creep deformation builds the second pillar of this work. Specific cutting processes of superdislocations are studied to elucidate which atomic processes take place. A series of left angle 100 right angle and

  3. Advances in speckle metrology and related techniques

    CERN Document Server

    Kaufmann, Guillermo H

    2010-01-01

    Speckle metrology includes various optical techniques that are based on the speckle fields generated by reflection from a rough surface or by transmission through a rough diffuser. These techniques have proven to be very useful in testing different materials in a non-destructive way. They have changed dramatically during the last years due to the development of modern optical components, with faster and more powerful digital computers, and novel data processing approaches. This most up-to-date overview of the topic describes new techniques developed in the field of speckle metrology over the l

  4. Moessbauer effect and TEM in mineralogy

    International Nuclear Information System (INIS)

    Ferrow, E.A.

    1994-01-01

    Moessbauer effect (ME) provides useful information on oxidation state, co-ordination number, co-ordination state, site occupancies, and magnetic properties of Fe-bearing phases. The information gained by ME together with the information provided by other conventional techniques is used to extract temperature, pressure, and kinetics of rock-forming processes. Nevertheless, ME requires that the phases studied are homogeneous over an extremely large volume and that Fe is a major component of the system. Transmission electron microscopy (TEM), on the other hand, provides similar information over a very small volume for a system of any component. However, present TEM spectrometers do not provide sufficient resolution to detect the mixed oxidation state. A complete characterisation of phases in rocks requires, therefore, that conventional techniques be combined with TEM. (orig.)

  5. Mathematics in computed tomography and related techniques

    International Nuclear Information System (INIS)

    Sawicka, B.

    1992-01-01

    The mathematical basis of computed tomography (CT) was formulated in 1917 by Radon. His theorem states that the 2-D function f(x,y) can be determined at all points from a complete set of its line integrals. Modern methods of image reconstruction include three approaches: algebraic reconstruction techniques with simultaneous iterative reconstruction or simultaneous algebraic reconstruction; convolution back projection; and the Fourier transform method. There is no one best approach. Because the experimental data do not strictly satisfy theoretical models, a number of effects have to be taken into account; in particular, the problems of beam geometry, finite beam dimensions and distribution, beam scattering, and the radiation source spectrum. Tomography with truncated data is of interest, employing mathematical approximations to compensate for the unmeasured projection data. Mathematical techniques in image processing and data analysis are also extensively used. 13 refs

  6. Nuclear and related techniques in parasitology

    International Nuclear Information System (INIS)

    Hayunga, E.G.; Stek, M. Jr.

    1986-05-01

    The course, entitled ''Atomic Energy Applications in Parasitology'', was offered by the Uniformed Services University of the Health Sciences, Bethesda, USA, during the summer of 1983. The course began with an exhaustive introduction to radiation physics, then encompassed a variety of practical applications including irradiation attenuation, radioisotope labeling, tracer techniques and radioimmunoassays. This laboratory manual was written by the faculty in an attempt to document the learning experience of the training course and to provide a detailed description of state-of-the-art technology, methods and procedures with up-to-date-references. A separate abstract was prepared for each of the 25 chapters in this manual

  7. Correlation of simulated TEM images with irradiation induced damage

    International Nuclear Information System (INIS)

    Schaeublin, R.; Almeida, P. de; Almazouzi, A.; Victoria, M.

    2000-01-01

    Crystal damage induced by irradiation is investigated using transmission electron microscopy (TEM) coupled to molecular dynamics (MD) calculations. The displacement cascades are simulated for energies ranging from 10 to 50 keV in Al, Ni and Cu and for times of up to a few tens of picoseconds. Samples are then used to perform simulations of the TEM images that one could observe experimentally. Diffraction contrast is simulated using a method based on the multislice technique. It appears that the cascade induced damage in Al imaged in weak beam exhibits little contrast, which is too low to be experimentally visible, while in Ni and Cu a good contrast is observed. The number of visible clusters is always lower than the actual one. Conversely, high resolution TEM (HRTEM) imaging allows most of the defects contained in the sample to be observed, although experimental difficulties arise due to the low contrast intensity of the smallest defects. Single point defects give rise in HTREM to a contrast that is similar to that of cavities. TEM imaging of the defects is discussed in relation to the actual size of the defects and to the number of clusters deduced from MD simulations

  8. Correlating TEM images of damage in irradiated materials to molecular dynamics simulations

    International Nuclear Information System (INIS)

    Schaeublin, R.; Caturla, M.-J.; Wall, M.; Felter, T.; Fluss, M.; Wirth, B.D.; Diaz de la Rubia, T.; Victoria, M.

    2002-01-01

    TEM image simulations are used to couple the results from molecular dynamics (MD) simulations to experimental TEM images. In particular we apply this methodology to the study of defects produced during irradiation. MD simulations have shown that irradiation of FCC metals results in a population of vacancies and interstitials forming clusters. The limitation of these simulations is the short time scales available, on the order of 100 s of picoseconds. Extrapolation of the results from these short times to the time scales of the laboratory has been difficult. We address this problem by two methods: we perform TEM image simulations of MD simulations of cascades with an improved technique, to relate defects produced at short time scales with those observed experimentally at much longer time scales. On the other hand we perform in situ TEM experiments of Au irradiated at liquid-nitrogen temperatures, and study the evolution of the produced damage as the temperature is increased to room temperature. We find that some of the defects observed in the MD simulations at short time scales using the TEM image simulation technique have features that resemble those observed in laboratory TEM images of irradiated samples. In situ TEM shows that stacking fault tetrahedra are present at the lowest temperatures and are stable during annealing up to room temperature, while other defect clusters migrate one dimensionally above -100 deg. C. Results are presented here

  9. In Situ TEM Electrical Measurements

    DEFF Research Database (Denmark)

    Canepa, Silvia; Alam, Sardar Bilal; Ngo, Duc-The

    2016-01-01

    understanding of complex physical and chemical interactions in the pursuit to optimize nanostructure function and device performance. Recent developments of sample holder technology for TEM have enabled a new field of research in the study of functional nanomaterials and devices via electrical stimulation...... influence the sample by external stimuli, e.g. through electrical connections, the TEM becomes a powerful laboratory for performing quantitative real time in situ experiments. Such TEM setups enable the characterization of nanostructures and nanodevices under working conditions, thereby providing a deeper...... and measurement of the specimen. Recognizing the benefits of electrical measurements for in situ TEM, many research groups have focused their effort in this field and some of these methods have transferred to ETEM. This chapter will describe recent advances in the in situ TEM investigation of nanostructured...

  10. TEM turbulence optimisation in stellarators

    Science.gov (United States)

    Proll, J. H. E.; Mynick, H. E.; Xanthopoulos, P.; Lazerson, S. A.; Faber, B. J.

    2016-01-01

    With the advent of neoclassically optimised stellarators, optimising stellarators for turbulent transport is an important next step. The reduction of ion-temperature-gradient-driven turbulence has been achieved via shaping of the magnetic field, and the reduction of trapped-electron mode (TEM) turbulence is addressed in the present paper. Recent analytical and numerical findings suggest TEMs are stabilised when a large fraction of trapped particles experiences favourable bounce-averaged curvature. This is the case for example in Wendelstein 7-X (Beidler et al 1990 Fusion Technol. 17 148) and other Helias-type stellarators. Using this knowledge, a proxy function was designed to estimate the TEM dynamics, allowing optimal configurations for TEM stability to be determined with the STELLOPT (Spong et al 2001 Nucl. Fusion 41 711) code without extensive turbulence simulations. A first proof-of-principle optimised equilibrium stemming from the TEM-dominated stellarator experiment HSX (Anderson et al 1995 Fusion Technol. 27 273) is presented for which a reduction of the linear growth rates is achieved over a broad range of the operational parameter space. As an important consequence of this property, the turbulent heat flux levels are reduced compared with the initial configuration.

  11. 40 keV atomic resolution TEM

    International Nuclear Information System (INIS)

    Bell, David C.; Russo, Christopher J.; Kolmykov, Dmitry V.

    2012-01-01

    Here we present the first atomic resolution TEM imaging at 40 keV using an aberration-corrected, monochromated source TEM. Low-voltage High-Resolution Electron Microscopy (LVHREM) has several advantages, including increased cross-sections for inelastic and elastic scattering, increased contrast per electron and improved spectroscopy efficiency, decreased delocalization effects and reduced knock-on damage. Together, these often improve the contrast to damage ratio obtained on a large class of samples. Third-order aberration correction now allows us to operate the TEM at low energies while retaining atomic resolution, which was previously impossible. At low voltage the major limitation to resolution becomes the chromatic aberration limit. We show that using a source monochromator we are able to reduce the effect of chromatic aberration and achieve a usable high-resolution limit at 40 keV to less than 1 Å. We show various materials' examples of the application of the technique to image graphene and silicon, and compare atomic resolution images with electron multislice simulations. -- Highlights: ► We present the first atomic resolution images recorded at 40 keV using an aberration-corrected, monochromated TEM. ► We show information transfer measured to better than 1 Å. ► At 40 keV an aberration-corrected monochromated TEM is limited by fifth-order spherical aberration. ► We show that using a monochromator the effect of chromatic aberration is reduced to enable high resolution imaging. ► Low voltage high resolution electron microscopy will be beneficial for imaging the organic/inorganic materials interface.

  12. Public Relations and Publicity: Tools and Techniques for Student Organizations.

    Science.gov (United States)

    DeFeo, Carol Jean

    Based on the idea that to be successful, a student organization must have a sound public relations and publicity program, this handbook considers techniques of internal communication that establish good public relations with various special groups: the student body, the administration, the faculty, and the staff. The handbook states that…

  13. Mastering data warehouse design relational and dimensional techniques

    CERN Document Server

    Imhoff, Claudia; Geiger, Jonathan G

    2003-01-01

    A cutting-edge response to Ralph Kimball''s challenge to the data warehouse community that answers some tough questions about the effectiveness of the relational approach to data warehousingWritten by one of the best-known exponents of the Bill Inmon approach to data warehousingAddresses head-on the tough issues raised by Kimball and explains how to choose the best modeling technique for solving common data warehouse design problemsWeighs the pros and cons of relational vs. dimensional modeling techniquesFocuses on tough modeling problems, including creating and maintaining keys and modeling c

  14. Nuclear and related techniques in animal production and health

    International Nuclear Information System (INIS)

    1986-01-01

    The international symposium was attended by about 130 participants from 45 countries and included 83 scientific presentations of which 42 were posters. This volume covers four principal and interrelated topics: adaptation of animals to the environment, and animal reproduction, health and nutrition. Within each topic, consideration is given to those nuclear and related techniques currently employed in investigative research and their usefulness in studying animal production systems. Progress towards new areas of application and new techniques is also covered, particularly the development and practicability of immunoassay and related biotechnological methods for the diagnosis of livestock diseases. A separate abstract was prepared for each of the papers in this volume

  15. TEM sample preparation by FIB for carbon nanotube interconnects

    International Nuclear Information System (INIS)

    Ke, Xiaoxing; Bals, Sara; Romo Negreira, Ainhoa; Hantschel, Thomas; Bender, Hugo; Van Tendeloo, Gustaaf

    2009-01-01

    A powerful method to study carbon nanotubes (CNTs) grown in patterned substrates for potential interconnects applications is transmission electron microscopy (TEM). However, high-quality TEM samples are necessary for such a study. Here, TEM specimen preparation by focused ion beam (FIB) has been used to obtain lamellae of patterned samples containing CNTs grown inside contact holes. A dual-cap Pt protection layer and an extensive 5 kV cleaning procedure are applied in order to preserve the CNTs and avoid deterioration during milling. TEM results show that the inner shell structure of the carbon nanotubes has been preserved, which proves that focused ion beam is a useful technique to prepare TEM samples of CNT interconnects.

  16. TEM sample preparation by FIB for carbon nanotube interconnects

    Energy Technology Data Exchange (ETDEWEB)

    Ke, Xiaoxing, E-mail: xiaoxing.ke@ua.ac.be [EMAT, University of Antwerp, Groenenborgerlaan 171, B-2020 Antwerp (Belgium); Bals, Sara [EMAT, University of Antwerp, Groenenborgerlaan 171, B-2020 Antwerp (Belgium); Romo Negreira, Ainhoa [IMEC, Kapeldreef 75, B-3001 Leuven (Belgium); Metallurgy and Materials Engineering Department, KU Leuven, Kasteelpark Arenberg 44, Leuven B-3001 (Belgium); Hantschel, Thomas; Bender, Hugo [IMEC, Kapeldreef 75, B-3001 Leuven (Belgium); Van Tendeloo, Gustaaf [EMAT, University of Antwerp, Groenenborgerlaan 171, B-2020 Antwerp (Belgium)

    2009-10-15

    A powerful method to study carbon nanotubes (CNTs) grown in patterned substrates for potential interconnects applications is transmission electron microscopy (TEM). However, high-quality TEM samples are necessary for such a study. Here, TEM specimen preparation by focused ion beam (FIB) has been used to obtain lamellae of patterned samples containing CNTs grown inside contact holes. A dual-cap Pt protection layer and an extensive 5 kV cleaning procedure are applied in order to preserve the CNTs and avoid deterioration during milling. TEM results show that the inner shell structure of the carbon nanotubes has been preserved, which proves that focused ion beam is a useful technique to prepare TEM samples of CNT interconnects.

  17. Scanning tunneling microscopy II further applications and related scanning techniques

    CERN Document Server

    Güntherodt, Hans-Joachim

    1995-01-01

    Scanning Tunneling Microscopy II, like its predecessor, presents detailed and comprehensive accounts of the basic principles and broad range of applications of STM and related scanning probe techniques. The applications discussed in this volume come predominantly from the fields of electrochemistry and biology. In contrast to those described in STM I, these studies may be performed in air and in liquids. The extensions of the basic technique to map other interactions are described in chapters on scanning force microscopy, magnetic force microscopy, and scanning near-field optical microscopy, together with a survey of other related techniques. Also described here is the use of a scanning proximal probe for surface modification. Together, the two volumes give a comprehensive account of experimental aspects of STM. They provide essential reading and reference material for all students and researchers involved in this field. In this second edition the text has been updated and new methods are discussed.

  18. Scanning tunneling microscopy II further applications and related scanning techniques

    CERN Document Server

    Güntherodt, Hans-Joachim

    1992-01-01

    Scanning Tunneling Microscopy II, like its predecessor, presents detailed and comprehensive accounts of the basic principles and broad range of applications of STM and related scanning probe techniques. The applications discussed in this volume come predominantly from the fields of electrochemistry and biology. In contrast to those described in Vol. I, these sudies may be performed in air and in liquids. The extensions of the basic technique to map other interactions are described inchapters on scanning force microscopy, magnetic force microscopy, scanning near-field optical microscopy, together with a survey of other related techniques. Also described here is the use of a scanning proximal probe for surface modification. Togehter, the two volumes give a comprehensive account of experimental aspcets of STM. They provide essentialreading and reference material for all students and researchers involvedin this field.

  19. Evaluating internal public relations using the critical incident technique

    NARCIS (Netherlands)

    Koning, K.H.; de Jong, Menno D.T.; van Vuuren, Hubrecht A.

    2015-01-01

    Although the critical incident technique (CIT) is one of the current methods in communication audits, little is known about the way it works. The validity of the CIT in the context of internal public relations depends on 3 assumptions: that participants can describe discrete communication events,

  20. Review of decontamination techniques in relation to decommissioning

    International Nuclear Information System (INIS)

    Jones, J.M.; Wakefield, J.R.

    1987-12-01

    A review is presented of decontamination procedures currently in use in relation to the decommissioning of nuclear plant. Contributions were invited from Canada, France, Japan, Sweden, USA and the UK and are appended. They present an overview of the techniques employed in each country and identify areas of future development. (author)

  1. Relative therapeuctic efficacy of vertebral mobilization technique in ...

    African Journals Online (AJOL)

    Relative therapeuctic efficacy of vertebral mobilization technique in the management of mechanical low back pain. ... Pre- and post-treatment pain scores among the subjects were compared to determine if there was any significant difference in the severity of pain. The difference in the severity of pain perception before and ...

  2. TEM-145 and TEM-146 β-lactamases produced by Escherichia coli ...

    African Journals Online (AJOL)

    GREGO

    2007-03-05

    Mar 5, 2007 ... Key words: Escherichia coli, plasmid-mediated, TEM β-lactamase. ... Enterobacteriaceae, the most prevalent mechanism of resistance to ... the production of a relatively inhibitor-resistant OXA-type β-lactamase .... and 8.6 as transcripts of the E. coli chromosomal AmpC .... Mode of action and mechanisms of.

  3. In situ mechanical TEM: seeing and measuring under stress with electrons

    International Nuclear Information System (INIS)

    Legros, M.

    2014-01-01

    From the first observation of moving dislocations in 1956 to the latest developments of piezo-actuated sample holders and direct electron sensing cameras in modern transmission electron microscopes (TEM), in situ mechanical testing has brought an unequaled view of the involved mechanisms during the plastic deformation of materials. Although MEMS-based or load-cell equipped holders provide an almost direct measure of these quantities, deriving stress and strain from in situ TEM experiments has an extensive history. Nowadays, the realization of a complete mechanical test while observing the evolution of a dislocation structure is possible, and it constitutes the perfect combination to explore size effects in plasticity. New cameras, data acquisition rates and intrinsic image-related techniques, such as holography, should extend the efficiency and capabilities of in situ deformation inside a TEM. (author)

  4. TEM-EELS: A personal perspective

    International Nuclear Information System (INIS)

    Egerton, R.F.

    2012-01-01

    The development of electron energy-loss spectroscopy in a transmission electron microscope (TEM-EELS) is illustrated through personal anecdote, highlighting some of the basic principles, instrumentation and personalities involved. The current state of the art is reviewed, together with some challenges for the future. -- Highlights: ► The history of EELS instrumentation is reviewed in a lighthearted manner. ► The current state of the art is summarized, together with some future possibilities. ► A couple of related mathematical puzzles are offered as a challenge to the reader.

  5. TEM investigations of laser ablated particles

    International Nuclear Information System (INIS)

    Fliegel, D.; Dundas, S.; Kosler, J.; Klementova, M.

    2009-01-01

    Full text: Laser ablation inductively coupled plasma mass spectrometry suffers from fractionation effects hindering a non matrix matched calibration strategy. Different reasons for elemental fractionation that are related to the laser ablation, the transport and the vaporization in the plasma are discussed. One major question to be addressed linked to the vaporization yield in the ICP is in which of mineralogical phase the different ablated particle sizes enter the plasma. This contribution will investigate particles generated by a 213 nm laser from different samples such as minerals and alloys with respect to their chemical and phase compositions using high resolution TEM. (author)

  6. Application of TEM to highly reactive metals

    International Nuclear Information System (INIS)

    Sherry, W.M.; Prinz, F.

    1982-01-01

    In the following a method for the preparation and observation of sodium TEM specimens and the first TEM micrograph ever to be published on the dislocation microstructure of sodium are reported. (orig./IHOE) [de

  7. An introduction to radioimmunoassay and related techniques. 3. rev. ed.

    International Nuclear Information System (INIS)

    Chard, T.

    1987-01-01

    This book is designed as an introductory text for the staff of clinical or research laboratories who conduct or intend to conduct radioimmunoassay and related immunoassay techniques, and will also be of great value to the clinicians who make use of such services. The emphasis is on general principles with practical illustrations rather than a detailed and encyclopaedic review of the literature. This 3rd revised edition places more emphasis on alternative labels (non-isotopic immunoassays), the use of labelled antibodies (immunometric assays), and the use of monoclonal antibodies. Both principles and practice are illustrated by diagrams and illustrations. (Auth.)

  8. Percutaneous embolization of varicocele: technique, indications, relative contraindications, and complications

    Directory of Open Access Journals (Sweden)

    Joshua Halpern

    2016-01-01

    Full Text Available There are several options for the treatment of varicocele, including surgical repair either by open or microsurgical approach, laparoscopy, or through percutaneous embolization of the internal spermatic vein. The ultimate goal of varicocele treatment relies on the occlusion of the dilated veins that drain the testis. Percutaneous embolization offers a rapid recovery and can be successfully accomplished in approximately 90% of attempts. However, the technique demands interventional radiologic expertise and has potential serious complications, including vascular perforation, coil migration, and thrombosis of pampiniform plexus. This review discusses the common indications, relative contraindications, technical details, and risks associated with percutaneous embolization of varicocele.

  9. ToTem: a tool for variant calling pipeline optimization.

    Science.gov (United States)

    Tom, Nikola; Tom, Ondrej; Malcikova, Jitka; Pavlova, Sarka; Kubesova, Blanka; Rausch, Tobias; Kolarik, Miroslav; Benes, Vladimir; Bystry, Vojtech; Pospisilova, Sarka

    2018-06-26

    High-throughput bioinformatics analyses of next generation sequencing (NGS) data often require challenging pipeline optimization. The key problem is choosing appropriate tools and selecting the best parameters for optimal precision and recall. Here we introduce ToTem, a tool for automated pipeline optimization. ToTem is a stand-alone web application with a comprehensive graphical user interface (GUI). ToTem is written in Java and PHP with an underlying connection to a MySQL database. Its primary role is to automatically generate, execute and benchmark different variant calling pipeline settings. Our tool allows an analysis to be started from any level of the process and with the possibility of plugging almost any tool or code. To prevent an over-fitting of pipeline parameters, ToTem ensures the reproducibility of these by using cross validation techniques that penalize the final precision, recall and F-measure. The results are interpreted as interactive graphs and tables allowing an optimal pipeline to be selected, based on the user's priorities. Using ToTem, we were able to optimize somatic variant calling from ultra-deep targeted gene sequencing (TGS) data and germline variant detection in whole genome sequencing (WGS) data. ToTem is a tool for automated pipeline optimization which is freely available as a web application at  https://totem.software .

  10. WHO activities in teaching radioimmunoassay and related techniques

    International Nuclear Information System (INIS)

    Goncharov, N.P.; Sufi, S.B.; Donaldson, A.; Jeffcoate, S.L.

    1986-01-01

    The Special Programme of Research, Development and Research Training in Human Reproduction of the World Health Organization has recognized from its beginning that training is a key component of its activities, including its immunoassay standardization programme. Since the start of the Special Programme more than 250 scientists have received training in RIA and related procedures and 27 training courses have been held in various countries. Many of the courses have been held in collaboration with the International Atomic Energy Agency, and these co-operative activities have established a core of scientific expertise worldwide which has contributed to the increased availability of modern diagnostic techniques in many countries. The increasing number of medical and non-medical applications of immunoassays and the special expertise required for some immunoassay methods create a continuing demand for training in RIA techniques. Both WHO and the IAEA have responded by organizing courses to 'train the trainers' and by supporting national and regional courses based on centrally provided material, as well as by commissioning the production of additional teaching documents and audio-visual aids in English and Spanish. It is envisaged that such materials, complete with centrally provided materials for practicals and other teaching aids, will be made available to national reagent programmes and will be used in the future as a well characterized, standardized core around which local organizers can construct training programmes geared to local needs and drawing upon local experience. (author)

  11. Relations between radiation risks and radiation protection measuring techniques

    International Nuclear Information System (INIS)

    Herrmann, K.; Kraus, W.

    Relations between radiation risks and radiation protection measuring techniques are considered as components of the radiation risk. The influence of the exposure risk on type and extent of radiation protection measurements is discussed with regard to different measuring tasks. Based upon measuring results concerning the frequency of certain external and internal occupational exposures in the GDR, it has been shown that only a small fraction of the monitored persons are subjected to a high exposure risk. As a consequence the following recommendations are presented: occupationally exposed persons with small exposure risk should be monitored using only a long-term desimeter (for instance a thermoluminescence desimeter). In the case of internal exposure, the surface and air contamination levels should be controlled so strictly that routine measurements of internal contamination need not be performed

  12. Optimized pre-thinning procedures of ion-beam thinning for TEM sample preparation by magnetorheological polishing.

    Science.gov (United States)

    Luo, Hu; Yin, Shaohui; Zhang, Guanhua; Liu, Chunhui; Tang, Qingchun; Guo, Meijian

    2017-10-01

    Ion-beam-thinning is a well-established sample preparation technique for transmission electron microscopy (TEM), but tedious procedures and labor consuming pre-thinning could seriously reduce its efficiency. In this work, we present a simple pre-thinning technique by using magnetorheological (MR) polishing to replace manual lapping and dimpling, and demonstrate the successful preparation of electron-transparent single crystal silicon samples after MR polishing and single-sided ion milling. Dimples pre-thinned to less than 30 microns and with little mechanical surface damage were repeatedly produced under optimized MR polishing conditions. Samples pre-thinned by both MR polishing and traditional technique were ion-beam thinned from the rear side until perforation, and then observed by optical microscopy and TEM. The results show that the specimen pre-thinned by MR technique was free from dimpling related defects, which were still residual in sample pre-thinned by conventional technique. Nice high-resolution TEM images could be acquired after MR polishing and one side ion-thinning. MR polishing promises to be an adaptable and efficient method for pre-thinning in preparation of TEM specimens, especially for brittle ceramics. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Suspended DNA structural characterization by TEM diffraction

    KAUST Repository

    Marini, Monica

    2017-12-01

    In this work, micro-fabrication, super-hydrophobic properties and a physiologically compatible preparation step are combined and tailored to obtain background free biological samples to be investigated by Transmission Electron Microscopy (TEM) diffraction technique. The validation was performed evaluating a well-known parameter such as the DNA interbases value. The diffraction spacing measured is in good agreement with those obtained by HRTEM direct metrology and by traditional X-Ray diffraction. This approach addresses single molecule studies in a simplified and reproducible straightforward way with respect to more conventional and widely used techniques. In addition, it overcomes the need of long and elaborated samples preparations: the sample is in its physiological environment and the HRTEM data acquisition occurs without any background interference, coating, staining or additional manipulation. The congruence in the results reported in this paper makes the application of this approach extremely promising towards those molecules for which crystallization remains a hurdle, such as cell membrane proteins and fibrillar proteins.

  14. Suspended DNA structural characterization by TEM diffraction

    KAUST Repository

    Marini, Monica; Allione, Marco; Lopatin, Sergei; Moretti, Manola; Giugni, Andrea; Torre, Bruno; Di Fabrizio, Enzo M.

    2017-01-01

    In this work, micro-fabrication, super-hydrophobic properties and a physiologically compatible preparation step are combined and tailored to obtain background free biological samples to be investigated by Transmission Electron Microscopy (TEM) diffraction technique. The validation was performed evaluating a well-known parameter such as the DNA interbases value. The diffraction spacing measured is in good agreement with those obtained by HRTEM direct metrology and by traditional X-Ray diffraction. This approach addresses single molecule studies in a simplified and reproducible straightforward way with respect to more conventional and widely used techniques. In addition, it overcomes the need of long and elaborated samples preparations: the sample is in its physiological environment and the HRTEM data acquisition occurs without any background interference, coating, staining or additional manipulation. The congruence in the results reported in this paper makes the application of this approach extremely promising towards those molecules for which crystallization remains a hurdle, such as cell membrane proteins and fibrillar proteins.

  15. Location specific in situ TEM straining specimens made using FIB

    International Nuclear Information System (INIS)

    Field, R.D.; Papin, P.A.

    2004-01-01

    A method has been devised and demonstrated for producing in situ straining specimens for the transmission electron microscope (TEM) from specific locations in a sample using a dual-beam focused ion beam (FIB) instrument. The specimen is removed from a polished surface in the FIB using normal methods and then attached to a pre-fabricated substrate in the form of a modified TEM tensile specimen. In this manner, specific features of the microstructure of a polished optical mount can be selected for in situ tensile straining. With the use of electron backscattered diffraction (EBSD), this technique could be extended to select specific orientations of the specimen as well

  16. A TEM Study on the Ti-Alloyed Grey Iron

    DEFF Research Database (Denmark)

    Moumeni, Elham; Tiedje, Niels Skat; Grumsen, Flemming Bjerg

    2014-01-01

    The microstructure of graphite flakes in titanium alloyed cast iron is studied using electron microscopy techniques. Dual beam SEM/FIB has been used for TEM sample preparation. A TEM study has been carried out on graphite flakes in grey cast iron using selected area electron diffraction. Based...... and that there is a high proportion of twins in the fine grained graphite. It appears that twinning and stacking faults are involved in the fine grained structure of the graphite. It is discussed how Ti addition affect crystal growth and may lead to formation of superfine graphite....

  17. Tem holder for sample transfer under reaction conditions

    DEFF Research Database (Denmark)

    Damsgaard, Christian Danvad; Zandbergen, Henny W.; Wagner, Jakob Birkedal

    Environmental transmission electron microscopy (ETEM) studies are usually performed using conventional sample holders in a dedicated ETEM [1] or in a traditional TEM by use of a dedicated high-pressure cell sample holder [2]. In both cases, the setup defines the conditions regarding gas, pressure......]. Furthermore, dedicated transfer holders have been used to transfer catalyst samples between reactor set-ups and TEM at room temperature in inert atmosphere [5]. To take the full advantage of complementary in situ techniques, transfer under reactions conditions is essential. This study introduces the in situ...... transfer concept by use of a dedicated TEM transfer holder capable of enclosing the sample in a gaseous environment at temperatures up to approx. 900C. By oxidation and reduction experiments of Cu nanoparticles it is shown possible to keep the reaction conditions during transfer outside the microscope...

  18. Disc electrophoresis and related techniques of polyacrylamide gel electrophoresis

    National Research Council Canada - National Science Library

    Maurer, H. R

    1971-01-01

    ..., enzymes, antingens and radioactively labelled materials, and detailed treatments of micro disc electrophoresis, preparative polyacrylamide gel electrophoresis and many other techniques for special problems...

  19. TEM sample preparation by femtosecond laser machining and ion milling for high-rate TEM straining experiments

    Energy Technology Data Exchange (ETDEWEB)

    Voisin, Thomas; Grapes, Michael D. [Dept. of Materials Science and Engineering, Johns Hopkins University, Baltimore, MD 21218 (United States); Zhang, Yong [Dept. of Mechanical Engineering, Johns Hopkins University, Baltimore, MD 21218 (United States); Lorenzo, Nicholas; Ligda, Jonathan; Schuster, Brian [US Army Research Laboratory, Aberdeen Proving Ground, Aberdeen, MD 21005 (United States); Weihs, Timothy P. [Dept. of Materials Science and Engineering, Johns Hopkins University, Baltimore, MD 21218 (United States)

    2017-04-15

    To model mechanical properties of metals at high strain rates, it is important to visualize and understand their deformation at the nanoscale. Unlike post mortem Transmission Electron Microscopy (TEM), which allows one to analyze defects within samples before or after deformation, in situ TEM is a powerful tool that enables imaging and recording of deformation and the associated defect motion during mechanical loading. Unfortunately, all current in situ TEM mechanical testing techniques are limited to quasi-static strain rates. In this context, we are developing a new test technique that utilizes a rapid straining stage and the Dynamic TEM (DTEM) at the Lawrence Livermore National Laboratory (LLNL). The new straining stage can load samples in tension at strain rates as high as 4×10{sup 3}/s using two piezoelectric actuators operating in bending while the DTEM at LLNL can image in movie mode with a time resolution as short as 70 ns. Given the piezoelectric actuators are limited in force, speed, and displacement, we have developed a method for fabricating TEM samples with small cross-sectional areas to increase the applied stresses and short gage lengths to raise the applied strain rates and to limit the areas of deformation. In this paper, we present our effort to fabricate such samples from bulk materials. The new sample preparation procedure combines femtosecond laser machining and ion milling to obtain 300 µm wide samples with control of both the size and location of the electron transparent area, as well as the gage cross-section and length. - Highlights: • Tensile straining TEM specimens made by femtosecond laser machining and ion milling. • Accurate positioning of the electron transparent area within a controlled gauge region. • Optimization of femtosecond laser and ion milling parameters. • Fast production of numerous samples with a highly repeatable geometry.

  20. Graceful, harmonious and magic type labelings relations and techniques

    CERN Document Server

    López, Susana C

    2017-01-01

    Aimed toward upper undergraduate and graduate students in mathematics, this book examines the foremost forms of graph labelings including magic, harmonious, and graceful labelings. An overview of basic graph theory concepts and notation is provided along with the origins of graph labeling. Common methods and techniques are presented introducing readers to links between graph labels. A variety of useful techniques are presented to analyze and understand properties of graph labelings. The classical results integrated with new techniques, complete proofs, numerous exercises, and a variety of open problems, will provide readers with a solid understanding of graph labelings.

  1. New constraints on deformation processes in serpentinite from sub-micron Raman Spectroscopy and TEM

    Science.gov (United States)

    Smith, S. A. F.; Tarling, M.; Rooney, J. S.; Gordon, K. C.; Viti, C.

    2017-12-01

    Extensive work has been performed to characterize the mineralogical and mechanical properties of the various serpentine minerals (i.e. antigorite, lizardite, chrysotile, polyhedral and polygonal serpentine). However, correct identification of serpentine minerals is often difficult or impossible using conventional analytical techniques such as optical- and SEM-based microscopy, X-ray diffraction and infrared spectroscopy. Transmission Electron Microscopy (TEM) is the best analytical technique to identify the serpentine minerals, but TEM requires complex sample preparation and typically results in very small analysis areas. Sub-micron confocal Raman spectroscopy mapping of polished thin sections provides a quick and relatively inexpensive way of unambiguously distinguishing the main serpentine minerals within their in-situ microstructural context. The combination of high spatial resolution (with a diffraction-limited system, 366 nm), large-area coverage (up to hundreds of microns in each dimension) and ability to map directly on thin sections allows intricate fault rock textures to be imaged at a sample-scale, which can then form the target of more focused TEM work. The potential of sub-micron Raman Spectroscopy + TEM is illustrated by examining sub-micron-scale mineral intergrowths and deformation textures in scaly serpentinites (e.g. dissolution seams, mineral growth in pressure shadows), serpentinite crack-seal veins and polished fault slip surfaces from a serpentinite-bearing mélange in New Zealand. The microstructural information provided by these techniques has yielded new insights into coseismic dehydration and amorphization processes and the interplay between creep and localised rupture in serpentinite shear zones.

  2. Global gyrokinetic simulations of TEM microturbulence

    Science.gov (United States)

    Vernay, T.; Brunner, S.; Villard, L.; McMillan, B. F.; Jolliet, S.; Bottino, A.; Görler, T.; Jenko, F.

    2013-07-01

    Global gyrokinetic simulations of electrostatic temperature-gradient-driven trapped-electron-mode (TEM) turbulence using the δf particle-in-cell code ORB5 are presented. The electron response is either fully kinetic or hybrid, i.e. considering kinetic trapped and adiabatic passing electrons. A linear benchmark in the TEM regime against the Eulerian-based code GENE is presented. Two different methods for controlling the numerical noise, based, respectively, on a Krook operator and a so-called coarse-graining approach, are discussed and successfully compared. Both linear and non-linear studies are carried out for addressing the issue of finite-ρ*-effects and finite electron collisionality on TEM turbulence. Electron collisions are found to damp TEMs through the detrapping process, while finite-ρ*-effects turn out to be important in the non-linear regime but very small in the linear regime. Finally, the effects of zonal flows on TEM turbulence are briefly considered as well and shown to be unimportant in the temperature-gradient-driven TEM regime. Consistently, basically no difference is found between linear and non-linear critical electron temperature gradients in the TEM regime.

  3. TEMS: results of a specialist centre.

    Science.gov (United States)

    Flexer, S M; Durham-Hall, A C; Steward, M A; Robinson, J M

    2014-06-01

    Transanal endoscopic microsurgery (TEMS) is becoming more widespread due to the increasing body of evidence to support its role. Previous published data has reported recurrence rates in excess of 10% for benign polyps after TEMS. Bradford Royal Infirmary is a tertiary referral centre for TEMS and early rectal cancer in the UK. Data for all TEMS operations were entered into a prospective database over a 7-year period. Demographic data, complications and recurrence rates were recorded. Both benign adenomas and malignant lesions were included. A total of 164 patients (65% male), with a mean age of 68 years were included; 114 (70%) of the lesions resected were benign adenomas, and 50 (30%) were malignant lesions. Median polyp size was 4 (range 0.6-14.5) cm. Mean length of operation was 55 (range 10-120) min. There were no recurrences in any patients with a benign adenoma resected; two patients with malignant lesions developed recurrences. Three intra-operative complications were recorded, two rectal perforations (repaired primarily, one requiring defunctioning stoma), and a further patient suffered a blood loss of >300 ml requiring transfusion. Six patients developed strictures requiring dilation either endoscopically or under anaesthetic in the post-operative period. We have demonstrated that TEMS procedures performed in a specialist centre provide low rates of both recurrence and complication. Within a specialist centre, TEMS surgery should be offered to all patients for rectal lesions, both benign and malignant, that are amenable to TEMS.

  4. TEM and EELS study of deuterated carbon: application to the fuel retention in tokamaks

    International Nuclear Information System (INIS)

    Bernier, N.

    2007-12-01

    We developed a methodology, based on the combination of TEM and EELS techniques, for a structural and chemical characterization, at a high spatial resolution, of a wide range of carbon materials. We i) optimized, in the framework of theoretical models, the sp2 fraction quantification from pure carbons by EELS ii) transferred this quantification to deuterated amorphous carbon layers iii) showed, from graphitized carbons, how the TEM-EELS combination allows to detect low concentrations of implanted D. Due to the accomplishment of these developments, we applied our approach to the study of D retention in composites C/C, which are the plasma-facing materials in TS. We showed that specific localized retention sites correspond to relatively large (∼ 3 mm.) cracks between fibres and matrix; such cracks offer a simple and direct path for deuterated amorphous carbon. The particle balance performed in TS is discussed in the light of this trapping mechanism. (author)

  5. ANALYSIS OF RELATIONS BETWEEN JUDO TECHNIQUES AND SPECIFIC MOTOR ABILITIES

    Directory of Open Access Journals (Sweden)

    Patrik Drid

    2006-06-01

    Full Text Available Specific physical preparation affects the development of motor abilities required for execution of specific movements in judo. When selecting proper specific exercises for judo for a target motor ability, it is necessary to precede it with the study of the structure of specific judo techniques and activities of individual muscle groups engaged for execution of the technique. On the basis of this, one can understand which muscles are most engaged during realization of individual techniques, which serves as a standpoint for selection of a particular complex of specific exercises to produce the highest effects. In addition to the development of particular muscle groups, the means of specific preparation will take effect on the development of those motor abilities which are evaluated as the indispensable for the development of particular qualities which are characteristic for judo. This paper analyses the relationship between judo techniques field and specific motor abilities.

  6. Tracer techniques for the study of host-parasite relations

    International Nuclear Information System (INIS)

    Mendgen, K.

    1975-01-01

    Autoradiographic techniques have been used to study the interaction of many facultative and obligate parasites, including viruses. After feeding the host plant with labelled substrates, labelled material accumulates in the infected cells and seems to penetrate into structures of the parasite. After labelling the parasite, its influence on the host may be studied. We use this technique to study the interaction of host (bean) and parasite (bean rust) during the infection process. After infection with uredospores labelled with tritiated orotic acid, the radioactivity is retained almost completely within the young haustorium at 22 h after inoculation. This may indicate a very small influence of the parasite on its compatible host. In incompatible host-parasite combinations, the infection process proceeds in a different way. The use of autoradiographic techniques to compare combinations of varying compatibilities will be discussed. (author)

  7. SAXS and TEM Investigation of Bentonite Structure

    International Nuclear Information System (INIS)

    Matusewicz, Michal; Liljestroem, Ville; Muurinen, Arto; Serimaa, Ritva

    2013-01-01

    A preliminary investigation of bentonite structure using Small-Angle X-ray Scattering (SAXS) and Transmission Electron Microscopy (TEM) is presented. Three types of clay were used: unchanged MX-80 bentonite and purified clays with sodium or calcium ions. Quantitative information in nano-scale - basal spacing, mean crystallite size - was obtained from SAXS, which was complemented by TEM to give qualitative information from micron to nanometre scale. SAXS seems to be a more reliable source of quantitative data than TEM. SAXS gives the averaged information about basal spacing. TEM in this study gives more qualitative information, but in a greater resolution range. The presented work is a starting point to combine more methods to obtain a better idea of bentonite structure. (authors)

  8. TEM of nanostructured metals and alloys

    International Nuclear Information System (INIS)

    Karnthaler, H.P.; Waitz, T.; Rentenberger, C.; Mingler, B.

    2004-01-01

    Nanostructuring has been used to improve the mechanical properties of bulk metals and alloys. Transmission electron microscopy (TEM) including atomic resolution is therefore appropriate to study these nanostructures; four examples are given as follows. (1) The early stages of precipitation at RT were investigated in an Al-Mg-Si alloy. By high resolution TEM it is shown that the precipitates lie on (0 0 1) planes having an ordered structure. (2) In Co alloys the fronts of martensitic phase transformations were analysed showing that the transformation strains are very small thus causing no surface relief. (3) Re-ordering and recrystallization were studied by in situ TEM of an Ni 3 Al alloy being nanocrystalline after severe plastic deformation. (4) In NiTi severe plastic deformation is leading to the formation of amorphous shear bands. From the TEM analysis it is concluded that the amorphization is caused by plastic shear instability starting in the shear bands

  9. Kirschner Wires : insertion techniques and bone related consequences

    NARCIS (Netherlands)

    Franssen, B.B.G.M.

    2010-01-01

    The Kirschner (K-) wire was first introduced in 1909 by Martin Kirschner. This is a thin unthreaded wire of surgical steel with a diameter of up to three millimeters and a selection of different tips. The use of K-wires is often promoted as a simple technique because of its easy placement,

  10. SOFC anode reduction studied by in situ TEM

    DEFF Research Database (Denmark)

    Simonsen, Søren Bredmose; Wagner, Jakob Birkedal; Hansen, Thomas Willum

    The Solid Oxide Fuel Cell (SOFC) is a promising part of future energy approaches due to a relatively high energy conversion efficiency and low environmental pollution. SOFCs are typically composed of ceramic materials which are highly complex at the nanoscale. TEM is routinely applied ex situ...... for studying these nanoscale structures, but only few SOFC studies have applied in situ TEM to observe the ceramic nanostructures in a reactive gas environment at elevated temperatures. The present contribution focuses on the reduction of an SOFC anode which is a necessary process to form the catalytically...... active Ni surface before operating the fuel cells. The reduction process was followed in the TEM while exposing a NiO/YSZ (YSZ = Y2O3-stabilized ZrO2) model anode to H2 at T = 250-1000⁰C. Pure NiO was used in reference experiments. Previous studies have shown that the reduction of pure Ni...

  11. Accelerator-tem interface facility and application

    International Nuclear Information System (INIS)

    Li Ming; He Jun; Yang Zheng; Zhou Lin; Liu Chuansheng; Guo Liping; Jiang Changzhong; Yang Shibo; Fu Dejun; Fan Xiangjun; Liu Jiarui; Lee, J.C.

    2010-01-01

    An accelerator-TEM interface facility has been established at Wuhan University. The system consists of an H800 TEM linked to a 200 kV ion implanter and a 2 x 1.7 MV tandetron accelerator. Measures were taken to isolate the TEM from mechanical vibration transmitted from the ion beam lines and good resolution was maintained with the TEM machine when operated under high zoom modes during the ion implantation. Nitrogen ions at 115 keV were successfully transported from the implanter into the TEM chamber through the interface system, and the ion currents measured at the entrance of the TEM column were between 20 and 180 nA. Structural evolution caused by ion irradiation in Si, GaAs, nanocrystal Ag were observed in situ. The TEM sample could be tilted by 52 degree and for low energy ion irradiation, real time observation was realized. The in situ observation showed that the critical implant dose for amorphization of Si is 2 x 10 14 cm -2 and it became fully amorphized at 3 x 10 15 cm -2 . Amorphization of GaAs started at 1 x 10 14 cm -2 , whereas for nanocrystal Ag, the starting dose was 6 x 10 14 cm -2 . The nuclear material C276 samples implanted with 115 keV Ar+ was also studied and dislocation loops with sizes of 3-12 nm were clearly observed after implantation to doses higher than 1 x 10 15 cm -2 . The density of the loops increased with the increase in the implant dose and evolution to polycrystalline and amorphous structures were observed at 5 x 10 15 cm -2 and 3 x 10 16 cm -2 , respectively. An in situ RBS/C chamber has been installed on the transport line of the accelerator-TEM interface system. This makes it possible to in situ measure composition and location of impurities in the lattice of the implanted samples. In addition, a 50 kV low-energy gaseous ion generator was installed close to the TEM chamber, which facilitates in situ TEM observation of helium bubbles formed in materials by helium implantation. (authors)

  12. Concerning the application of the nuclear and related techniques

    International Nuclear Information System (INIS)

    Desdin Garcia, Luis Felipe

    1997-01-01

    The present work intends to describe briefly, some of the nuclear and connected techniques of greater application in the conditions of developing countries, which are employed in the Center of Studies Applied to the Nuclear Development, and that can be of interest for the Latin-American countries. Within those techniques we have: radiobiology, that consists of the employment of ionizing radiations to induce mutations oriented to the improvement of the cultivations. It mentions the atmospheric contamination generated by the industry of the exposition to metals and toxic waste, and of mortiferous parasites that adapt quickly to the unhealthy environmental conditions. It also enumerates some advantages of the utilization of instruments based on radioisotopic fountains. (S. Grainger) [es

  13. Studies on osteoporosis in Chile using isotope-related techniques

    International Nuclear Information System (INIS)

    Lobo, G.; Palma, T.; Cortes-Toro, E.

    1996-01-01

    Several studies on bone densitometry measurements in healthy individuals have been performed in Chile. However due to the fact that different techniques and no uniform protocols have been used to select patients, the results obtained are not suitable as reference values for a normal chilean population. Therefore, foreign reference values are used. This study will select healthy normal individuals, typical urban chilean residents, and measure bone density using the DEXA technique. The selection will be made according to a well defined protocol. Serum osteocalcin, a marker of bone remodeling, will be measured in all subjects as a means-a assessing bone metabolism. Bone trace element composition will be measured in selected subjects. Samples will be obtained by biopsy or through normal surgical procedures and will be analyzed by neutron activation analysis. (author)

  14. TEM specimen preparation of semiconductor-PMMA-metal interfaces

    International Nuclear Information System (INIS)

    Thangadurai, P.; Lumelsky, Yulia; Silverstein, Michael S.; Kaplan, Wayne D.

    2008-01-01

    Transmission electron microscopy (TEM) cross-section specimens of PMMA in contact with gold and Si were prepared by focused ion beam (FIB) and compared with plan-view PMMA specimens prepared by a dip-coating technique. The specimens were characterized by TEM and electron energy loss spectroscopy (EELS). In the cross-section specimens, the thin films of PMMA were located in a Si-PMMA-Au multilayer. Different thicknesses of PMMA films were spin-coated on the Si substrates. The thickness of the TEM specimens prepared by FIB was estimated using EELS to be 0.65 of the plasmon mean-free-path. Along the PMMA-Au interface, Au particle diffusion into the PMMA was observed, and the size of the Au particles was in the range of 2-4 nm. Dip-coating of PMMA directly on Cu TEM grids resulted in thin specimens with a granular morphology, with a thickness of 0.58 of the plasmon mean-free-path. The dip-coated specimens were free from ion milling induced artifacts, and thus serve as control specimens for comparison with the cross-sectioned specimens prepared by FIB

  15. Characterization of some biological specimens using TEM and SEM

    Science.gov (United States)

    Ghosh, Nabarun; Smith, Don W.

    2009-05-01

    The advent of novel techniques using the Transmission and Scanning Electron Microscopes improved observation on various biological specimens to characterize them. We studied some biological specimens using Transmission and Scanning Electron Microscopes. We followed negative staining technique with Phosphotungstic acid using bacterial culture of Bacillus subtilis. Negative staining is very convenient technique to view the structural morphology of different samples including bacteria, phage viruses and filaments in a cell. We could observe the bacterial cell wall and flagellum very well when trapped the negative stained biofilm from bacterial culture on a TEM grid. We cut ultra thin sections from the fixed root tips of Pisum sativum (Garden pea). Root tips were pre fixed with osmium tetroxide and post fixed with uranium acetate and placed in the BEEM capsule for block making. The ultrathin sections on the grid under TEM showed the granular chromatin in the nucleus. The protein bodies and large vacuoles with the storage materials were conspicuous. We followed fixation, critical point drying and sputter coating with gold to view the tissues with SEM after placing on stubs. SEM view of the leaf surface of a dangerous weed Tragia hispida showed the surface trichomes. These trichomes when break on touching releases poisonous content causing skin irritation. The cultured tissue from in vitro culture of Albizia lebbeck, a tree revealed the regenerative structures including leaf buds and stomata on the tissue surface. SEM and TEM allow investigating the minute details characteristic morphological features that can be used for classroom teaching.

  16. Pilot production of track etch membranes (TEMS) using heavy ion beam scanner

    International Nuclear Information System (INIS)

    Nair, J.P.; Surendran, P.; Sparrow, Hillary; Ninawe, N.G.; Bhagwat, P.V.; Acharya, N.; Kulshreshta, V.; Rajesh Kumar; Vijay, Y.K.; Kurup, M.B.

    2005-01-01

    Various methods for making TEMs were conducted at Pelletron Accelerator Facility. The technique for production using ion beam scattering was also established. This is an effort to make TEMs on pilot basis at BARC- TIFR Pelletron Accelerator using Heavy Ion Beam Scanner till large rolling mechanism is implemented

  17. Oxidation in ceria infiltrated metal supported SOFCs – A TEM investigation

    DEFF Research Database (Denmark)

    Knibbe, Ruth; Wang, Hsiang-Jen; Blennow Tullmar, Peter

    2013-01-01

    electron microscopy (TEM) techniques including energy-dispersive X-ray spectroscopy and electron energy-loss spectroscopy of focus ion beamed TEM samples. The infiltrated CGO is predominately converted into CeFeO3 after high temperature processing, protecting the alloy. A thin layer of Cr-oxide is observed...

  18. Accelerator-TEM interface facility and application

    International Nuclear Information System (INIS)

    Liu Chuansheng; Li Ming; He Jun; Yang Zheng; Zhou Lin; Wang Zesong; Guo Liping; Jiang Changzhong; Yang Shibo; Fu Dejun; Fan Xiangjun; Liu Jiarui; Lee J C

    2010-01-01

    An accelerator-TEM interface facility has been established at Wuhan University in 2008. The system consists of an H800 TEM linked to a 200 kV ion implanter and a 2 x 1.7 MV tandem accelerator. Nitrogen ions at 115 keV were successfully transported from the implanter into the TEM chamber through the interface system, and the ion currents measured at the entrance of the TEM column were between 20 and 180 nA. Structural evolution caused by ion irradiation in Si, GaAs, nanocrystal Ag was observed in situ. The in situ observation showed that the critical implantation dose for amorphization of Si is 10 14 cm -2 . The nuclear material C276 samples implanted with 115 keV Ar + was also studied, and dislocation loops sized at 3-12 nm were clearly observed after implantation to doses of over 1 x 10 15 cm -2 . The density of the loops increased with the dose. Evolution to polycrystalline and amorphous structures were observed at 5 x l0 15 cm -2 and 3 x 10 16 cm -2 , respectively. An in situ RBS/C chamber was installed on the transport line of the accelerator-TEM interface system. This enables in situ measurement of composition and location of the implanted species in lattice of the samples. In addition, a 50 kV low-energy gaseous ion generator was installed close to the TEM chamber, which facilitates in situ TEM observation of helium bubbles formed in helium-implanted materials. (authors)

  19. Studies of osteoporosis in Shanghai, China, using isotope related techniques

    International Nuclear Information System (INIS)

    Zhang Yongpeng

    2000-01-01

    This paper deals with the osteoporosis model of New Zealand rabbits in order to study the functions of inorganic elements for women patients with osteoporosis. The thirty cases of iliac crest are collected and determined using Neutron Activation Analysis (NAA) technique. The results show that the Fluorine concentrations in experimental group are higher than those in control group and the Magnesium concentrations are lower significantly (P<0.001), but the concentrations of K, Na, Ca, Ba, Mn, Sr are not remarkable difference. Combined with the serum biochemical markers of bone formation and resorption, the physiological functions of some metal elements in bone are also discussed. (author)

  20. Nuclear and related techniques in the control of communicable diseases

    International Nuclear Information System (INIS)

    1991-07-01

    The IAEA has a programme component entitled ''Nuclear Techniques in Communicable Diseases'', the aims of which are to encourage research in the development of new methods of controlling communicable diseases and to transfer the technology to institutes in endemic regions. Implementation of the programme component includes information exchange through publications, symposiums and seminars. The two most recent seminars were held in Bombay in November 1988 and Belo Horizonte in November 1989, and a selection of the papers presented have been published in this Technical Document. Refs, figs and tabs

  1. Complete Tem-Tomography: 3D Structure of Gems Cluster

    Science.gov (United States)

    Matsuno, J.; Miyake, A.; Tsuchiyama, A.; Messenger, S.; Nakamura-Messenger, K.

    2015-01-01

    GEMS (glass with embedded metal and sulfide) grains in interplanetary dust particles (IDPs) are considered to be one of the ubiquitous and fundamental building blocks of solids in the Solar System. They have been considered to be interstellar silicate dust that survived various metamorphism or alteration processes in the protoplanetary disk but the elemental and isotopic composition measurements suggest that most of them have been formed in the protoplanetary disk as condensates from high temperature gas. This formation model is also supported by the formation of GEMS-like grains with respect to the size, mineral assemblage, texture and infrared spectrum by condensation experiments from mean GEMS composition materials. Previous GEMS studies were performed only with 2D observation by transmission electron microscopy (TEM) or scanning TEM (STEM). However, the 3D shape and structure of GEMS grains and the spatial distribution of Fe/FeS's has critical information about their formation and origin. Recently, the 3D structure of GEMS grains in ultrathin sections of cluster IDPs was revealed by electron tomography using a TEM/STEM (JEM-2100F, JEOL). However, CT images of thin sections mounted on Cu grids acquired by conventional TEM-tomography are limited to low tilt angles (e. g., less than absolute value of 75 deg. In fact, previous 3D TEM observations of GEMS were affected by some artifacts related to the limited tilt range in the TEM used. Complete tomographic images should be acquired by rotating the sample tilt angle over a range of more than absolute value of 80 deg otherwise the CT images lose their correct structures. In order to constrain the origin and formation process of GEMS grains more clearly, we performed complete electron tomography for GEMS grains. Here we report the sample preparation method we have developed for this study, and the preliminary results.

  2. Studies of osteoporosis in Croatia using isotope related techniques

    International Nuclear Information System (INIS)

    Dekanic, D.; Blanusa, M.; Cvijetic, S.; Prester, L.; Uzelac, V.

    1996-01-01

    A short overview is presented of research activities concerning osteoporosis and trace element exposure monitoring carried out by the Institute for Medical Research and Occupational Health in Zagreb during the last forty years. The overview includes: cross-sectional and Prospective epidemiological studies in districts with habitually low and high calcium intake; clinical studies concerning peak bone mass and bone mineral density in Postmenopausal women; studies on trace element exposure monitoring. The collaborating institutions, agencies and relevant recent publications are quoted. A survey is given of relevant methods which were used in earlier studies as well as the techniques which will be used in the current IAEA project. A brief description of the work which will be undertaken (particularly during the first year) within the framework of the IAEA CRP is given. (author)

  3. The role of hypnosis and related techniques in insomnia

    Directory of Open Access Journals (Sweden)

    Serban Ionela Lacramioara

    2013-01-01

    Full Text Available Hypnosis is a widespread technique in psychotherapy with applicability in various psychiatric and psychosomatic disorders. Although there are very few studies in this area of research, some results argue in favor of using hypnosis for various sleep disorders. Insomnia is a common health problem, in both primary form and associated with other pathologies, causing a reduction of self-efficiency/cognitive abilities and an overall decreased life quality. Classical psychotropic medication that is commonly used to treat insomnia can cause significant side effects, produce phenomena of dependence and is generally effective only during the period of treatment. Since the current means of pharmacologic treatment for insomnia present significant limitations, especially when treating chronic insomnia, a more suitable alternative could be attained by non-pharmacological approaches such as hypnosis.

  4. Analytical TEM investigations of nanoscale magnetic materials

    International Nuclear Information System (INIS)

    Meingast, A.

    2015-01-01

    Analytical transmission electron microscopy has been applied within this thesis to investigate several novel approaches to design and fabricate nanoscale magnetic materials. As the size of the features of interest rank in the sub-nanometer range, it is necessary to employ techniques with a resolution – both spatial and analytical – well below this magnitude. Only at this performance level it is possible to examine material properties, necessary for the further tailoring of materials. Within this work two key aspects have been covered: First, analytical TEM (transmission electron microscopy) investigations were carried out to get insight into novel magnetic materials with high detail. Second, new analytical and imaging possibilities enabled with the commissioning of the new ASTEM (Austrian scanning transmission electron microscope) were explored. The aberration corrected TITAN® microscope (© FEI Company) allows resolving features in scanning transmission mode (STEM) with 70 pm distance. Thereby, direct imaging of light elements in STEM mode by using the annular bright field method becomes possible. Facilitated through high beam currents within the electron probe, an increased acquisition speed of analytical signals is possible. For energy dispersive X-ray spectroscopy (EDXS) a new four detector disc geometry around the specimen was implemented, which increases the accessible collection angle. With the integration of the latest generation of image filter and electron spectrometer (GIF QuantumERS), electron energy loss spectroscopy (EELS) is boosted through the high acquisition speed and the dual spectroscopy mode. The high acquisition speed allows to record up to 1000 spectra per second and the possibility to record atomically resolved EELS maps is at hand. Hereby it is important to avoid beam damage and alteration of the material during imaging and analysis. With the simultaneous acquisition of the low and the high loss spectral region, an extended range for

  5. Simple technique for measuring relative renal blood flow

    International Nuclear Information System (INIS)

    Shames, D.M.; Korobkin, M.

    1976-01-01

    To determine whether externally monitored early renal uptake of 131 I-hippurate is proportional to renal blood flow, the renal uptake of 131 -hippurate at 1 to 2 min after injection was compared with the renal accumulation of radioactive carbonized microspheres in dogs. A renal artery catheter equipped with a balloon was used to decrease renal blood flow unilaterally. One minute after the intravenous injection of 100 μCi of 131 I-hippurate, about 1 μCi of either 85 Sr- or 95 Nb-labeled carbon microspheres was injected into the left ventricle. Radioactivity was measured over both kidneys. The total radioactivity within each kidney region of interest was corrected for background and integrated over the 1 to 2 min interval after injection. Thirteen measurements of relative renal blood flow were made for seven dogs. The dogs were then killed and both kidneys were excised and counted for the radioactivity of the microspheres. The 1 to 2-min relative renal uptake of 131 I-hippurate correlated well with relative microsphere uptake, suggesting that relative renal blood flow can be simply determined from the external measurements of renal uptake of 131 I-hippurate

  6. Sensitivity analysis and related analysis : A survey of statistical techniques

    NARCIS (Netherlands)

    Kleijnen, J.P.C.

    1995-01-01

    This paper reviews the state of the art in five related types of analysis, namely (i) sensitivity or what-if analysis, (ii) uncertainty or risk analysis, (iii) screening, (iv) validation, and (v) optimization. The main question is: when should which type of analysis be applied; which statistical

  7. In Situ Environmental TEM in Imaging Gas and Liquid Phase Chemical Reactions for Materials Research.

    Science.gov (United States)

    Wu, Jianbo; Shan, Hao; Chen, Wenlong; Gu, Xin; Tao, Peng; Song, Chengyi; Shang, Wen; Deng, Tao

    2016-11-01

    Gas and liquid phase chemical reactions cover a broad range of research areas in materials science and engineering, including the synthesis of nanomaterials and application of nanomaterials, for example, in the areas of sensing, energy storage and conversion, catalysis, and bio-related applications. Environmental transmission electron microscopy (ETEM) provides a unique opportunity for monitoring gas and liquid phase reactions because it enables the observation of those reactions at the ultra-high spatial resolution, which is not achievable through other techniques. Here, the fundamental science and technology developments of gas and liquid phase TEM that facilitate the mechanistic study of the gas and liquid phase chemical reactions are discussed. Combined with other characterization tools integrated in TEM, unprecedented material behaviors and reaction mechanisms are observed through the use of the in situ gas and liquid phase TEM. These observations and also the recent applications in this emerging area are described. The current challenges in the imaging process are also discussed, including the imaging speed, imaging resolution, and data management. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Nuclear and related techniques in parasitology: A laboratory manual

    Energy Technology Data Exchange (ETDEWEB)

    Hayunga, E.G.; Stek, M. Jr. (eds.)

    1986-01-01

    The course, entitled ''Atomic Energy Applications in Parasitology'', was offered by the Division of Tropical Public Health, Department of Preventive Medicine, and Biometrics, Uniformed Services University of the Health Sciences, Bethesda, Maryland. It was an intensive 3-week endeavor during which students attended lectures and acquired practical hands-on experience with the most recent laboratory tools. The course began with an exhaustive introduction to radiation physics, then encompassed a variety of practical applications including irradiation attenuation, radioisotope labeling, tracer techniques and radioimmunoassays. This laboratory manual was written by the faculty in an attempt to document the learning experience of the training course and to provide a detailed description of state-of-the-art technology with up-to-date references. Clearly, the manual has value as a historical document. However, the chapters were written with the explicit intention that they be useful to future investigators who wish to apply these methods to their particular research problem.

  9. Relative strength of tailor's bunion osteotomies and fixation techniques.

    Science.gov (United States)

    Haddon, Todd B; LaPointe, Stephan J

    2013-01-01

    A paucity of data is available on the mechanical strength of fifth metatarsal osteotomies. The present study was designed to provide that information. Five osteotomies were mechanically tested to failure using a materials testing machine and compared with an intact fifth metatarsal using a hollow saw bone model with a sample size of 10 for each construct. The osteotomies tested were the distal reverse chevron fixated with a Kirschner wire, the long plantar reverse chevron osteotomy fixated with 2 screws, a mid-diaphyseal sagittal plane osteotomy fixated with 2 screws, the mid-diaphyseal sagittal plane osteotomy fixated with 2 screws, and an additional cerclage wire and a transverse closing wedge osteotomy fixated with a box wire technique. Analysis of variance was performed, resulting in a statistically significant difference among the data at p chevron was statistically the strongest construct at 130 N, followed by the long plantar osteotomy at 78 N. The chevron compared well with the control at 114 N, and they both fractured at the proximal model to fixture interface. The other osteotomies were statistically and significantly weaker than both the chevron and the long plantar constructs, with no statistically significant difference among them at 36, 39, and 48 N. In conclusion, the chevron osteotomy was superior in strength to the sagittal and transverse plane osteotomies and similar in strength and failure to the intact model. Copyright © 2013 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  10. Air pollution in Thailand using nuclear-related analytical techniques

    International Nuclear Information System (INIS)

    Leelhaphunt, N.; Chueinta, W.

    1994-01-01

    The methods of neutron activation, both instrumental and radiochemical, and atomic absorption spectrophotometry are used in a study of the concentrations of Al, As, Br, Cd, Cl, Co, Cr, Cu, Fe, Hg, Mn, Sb, Sc, Se, Si, V, Zn and Pb in airborne particulate matter collected from 7 permanent and 9 temporary air quality monitoring stations. The location of the stations are urban residential, suburban residential, mixed (commercial and residential), commercial and industrial areas and near major roads in Bangkok Metropolitan areas. Air sampling is performed once a month for 24 hours continuously using the high volume air sampler (GMW 2000 H) and for 5, 10, and 15 days continuously using an Anderson Air Sampler (SIBATA AN-200). The elements As, Cd and Cu are determined destructively using ion exchange chromatography while Hg and Se are determined by the dry combustion technique. The determination of Pb was done by atomic absorption spectrophotometry. The results of Pb concentrations in airborne particulate matters, collected during 1987 to 1991, were reported by the Office of the National Environment Board. Levels of Pb content were found to be lower than the National Ambient Air Quality Standards. (author). 3 refs, 4 tabs

  11. Integrative techniques related to positive processes in psychotherapy.

    Science.gov (United States)

    Cromer, Thomas D

    2013-09-01

    This review compiles and evaluates a number of therapist interventions that have been found to significantly contribute to positive psychotherapy processes (i.e., increased alliance, patient engagement/satisfaction, and symptomatic improvement). Four forms of intervention are presented: Affect-focused, Supportive, Exploratory, and Patient-Therapist Interaction. The intention of this review is to link specific interventions to applied practice so that integrative clinicians can potentially use these techniques to improve their clinical work. To this end, there is the inclusion of theory and empirical studies from a range of orientations including Emotionally Focused, Psychodynamic, Client-Centered, Cognitive-Behavioral, Interpersonal, Eclectic, and Motivational Interviewing. Each of the four sections will include the theoretical basis and proposed mechanism of change for the intervention, research that supports its positive impact on psychotherapy processes, and conclude with examples demonstrating its use in actual practice. Clinical implications and considerations regarding the use of these interventions will also be presented. 2013 APA, all rights reserved

  12. X-ray fluorescence spectrometry and related techniques an introduction

    CERN Document Server

    Margui, Eva

    2013-01-01

    X-ray fluorescence spectrometry (XRF) is a well-established analytical technique for qualitative and quantitative elemental analysis of a wide variety of routine quality control and research samples. Among its many desirable features, it delivers true multi-element character analysis, acceptable speed and economy, easy of automation, and the capacity to analyze solid samples. This remarkable contribution to this field provides a comprehensive and up-to-date account of basic principles, recent developments, instrumentation, sample preparation procedures, and applications of XRF analysis. If you are a professional in materials science, analytic chemistry, or physics, you will benefit from not only the review of basics, but also the newly developed technologies with XRF. Those recent technological advances, including the design of low-power micro- focus tubes and novel X-ray optics and detectors, have made it possible to extend XRF to the analysis of low-Z elements and to obtain 2D or 3D information on a microme...

  13. Identifying content-based and relational techniques to change behaviour in motivational interviewing.

    Science.gov (United States)

    Hardcastle, Sarah J; Fortier, Michelle; Blake, Nicola; Hagger, Martin S

    2017-03-01

    Motivational interviewing (MI) is a complex intervention comprising multiple techniques aimed at changing health-related motivation and behaviour. However, MI techniques have not been systematically isolated and classified. This study aimed to identify the techniques unique to MI, classify them as content-related or relational, and evaluate the extent to which they overlap with techniques from the behaviour change technique taxonomy version 1 [BCTTv1; Michie, S., Richardson, M., Johnston, M., Abraham, C., Francis, J., Hardeman, W., … Wood, C. E. (2013). The behavior change technique taxonomy (v1) of 93 hierarchically clustered techniques: Building an international consensus for the reporting of behavior change interventions. Annals of Behavioral Medicine, 46, 81-95]. Behaviour change experts (n = 3) content-analysed MI techniques based on Miller and Rollnick's [(2013). Motivational interviewing: Preparing people for change (3rd ed.). New York: Guildford Press] conceptualisation. Each technique was then coded for independence and uniqueness by independent experts (n = 10). The experts also compared each MI technique to those from the BCTTv1. Experts identified 38 distinct MI techniques with high agreement on clarity, uniqueness, preciseness, and distinctiveness ratings. Of the identified techniques, 16 were classified as relational techniques. The remaining 22 techniques were classified as content based. Sixteen of the MI techniques were identified as having substantial overlap with techniques from the BCTTv1. The isolation and classification of MI techniques will provide researchers with the necessary tools to clearly specify MI interventions and test the main and interactive effects of the techniques on health behaviour. The distinction between relational and content-based techniques within MI is also an important advance, recognising that changes in motivation and behaviour in MI is a function of both intervention content and the interpersonal style

  14. Update on procedure-related risks for prenatal diagnosis techniques

    DEFF Research Database (Denmark)

    Tabor, Ann; Alfirevic, Zarko

    2010-01-01

    Introduction: As a consequence of the introduction of effective screening methods, the number of invasive prenatal diagnostic procedures is steadily declining. The aim of this review is to summarize the risks related to these procedures. Material and Methods: Review of the literature. Results: Data...... from randomised controlled trials as well as from systematic reviews and a large national registry study are consistent with a procedure-related miscarriage rate of 0.5-1.0% for amniocentesis as well as for chorionic villus sampling (CVS). In single-center studies performance may be remarkably good due...... not be performed before 15 + 0 weeks' gestation. CVS on the other hand should not be performed before 10 weeks' gestation due to a possible increase in risk of limb reduction defects. Discussion: Experienced operators have a higher success rate and a lower complication rate. The decreasing number of prenatal...

  15. Observing cataclysmic variables and related objects with different techniques

    Czech Academy of Sciences Publication Activity Database

    Šimon, Vojtěch

    2012-01-01

    Roč. 83, č. 2 (2012), s. 675-682 ISSN 0037-8720. [Workshop on the golden age of cataclysmic variables and related objects /2./. Palermo , 09.09.2013-14.09.2013] R&D Projects: GA ČR GA205/08/1207 Institutional research plan: CEZ:AV0Z10030501 Keywords : X-rays * binaries * circumstellar matter Subject RIV: BN - Astronomy, Celestial Mechanics, Astrophysics

  16. Scanning tunneling microscopy - STM: history, principle, construction, and related techniques

    International Nuclear Information System (INIS)

    Ostadal, I.; Sobotik, P.

    1998-01-01

    The method of scanning tunneling microscopy (STM) is discussed. The principle of STM and some other related methods is highlighted, and spectroscopy using STM is dealt with. A brief summary is given of problems to be solved in microscope design, and the influence of these on the resolution obtained is presented. A comparison of STM with other methods used at present in the physics of thin films and surfaces confirms its irreplaceability

  17. Studies on osteoporosis in Chile using isotope-related techniques

    International Nuclear Information System (INIS)

    Lobo, G.

    1998-01-01

    The relationship found between BMD of the lumbar spine with the anthropomorphic parameters (age, sex, body size and bone area) in the normal Chilean population studied, was different from the relationship found between BMD of both hips with the same parameters. To determine peak bone mass it is necessary to increase the number of individuals studied. This is specially true for BMD of the lumbar spine. It seems important for the correct interpretation of BMD studies to determine local values for normals, specially for the analysis of BMD in the lumbar spine, which is related to body and bone size. It is necessary to normalize the data base for anthropomorphic parameters specially in epidemiological studies. Knowledge of these parameters for the normal data base used in the different densitometers is highly desirable. There are some differences between this data base and that provided by Hologic, specially for spine in both sexes. This difference could be explained by size related factors. There is a correlation between osteocalcin levels and BMD in lumbar spine and both femoral necks only in women

  18. Destructive interference of TEM and ITG turbulence

    International Nuclear Information System (INIS)

    Merz, F.; Jenko, F.

    2009-01-01

    Full text: Turbulence driven by ion temperature gradient (ITG) modes and trapped electron modes (TEMs) is generally considered the key mechanism for anomalous transport in fusion devices on ion scales. But while pure ITG and, to a lesser extent, also pure TEM turbulence have been studied in detail over the last years, not much is presently known about nonlinear interactions between ITG modes and TEMs, which are often present simultaneously in experimentally relevant situations. This important issue is addressed by means of linear and nonlinear gyrokinetic simulations with the GENE code. To examine the properties of the (linear) TEM and ITG instabilities in the (realistic) transitional regime, the GENE code is run as eigenvalue solver, which allows for a systematic study of dominant and subdominant modes. Corresponding nonlinear initial value computations show that the particle transport of the turbulent system can be completely suppressed if the two driving instabilities are active simultaneously. The direct comparison of the linear modes and the corresponding turbulent system reveals a coexistence of the two microinstabilities in a transitional regime even at the same wave number. The consequences of this dual turbulence drive for transport modeling is discussed. (author)

  19. In Situ TEM Creation of Nanowire Devices

    DEFF Research Database (Denmark)

    Alam, Sardar Bilal

    Integration of silicon nanowires (SiNWs) as active components in devices requires that desired mechanical, thermal and electrical interfaces can be established between the nanoscale geometry of the SiNW and the microscale architecture of the device. In situ transmission electron microscopy (TEM),...

  20. Test for English Majors (TEM) in China

    Science.gov (United States)

    Jin, Yan; Fan, Jinsong

    2011-01-01

    The purpose of the Test for English Majors (TEM) is to measure the English proficiency of Chinese university undergraduates majoring in English Language and Literature and to examine whether these students meet the required levels of English language abilities as specified in the National College English Teaching Syllabus for English Majors…

  1. Nonlinear entropy transfer in ETG-TEM turbulence via TEM driven zonal flows

    International Nuclear Information System (INIS)

    Asahi, Yuuichi; Tsutsui, Hiroaki; Tsuji-Iio, Shunji; Ishizawa, Akihiro; Sugama, Hideo; Watanabe, Tomohiko

    2015-01-01

    Nonlinear interplay of the electron temperature gradient (ETG) modes and the trapped electron modes (TEMs) was investigated by means of gyrokinetic simulation. Focusing on the situation where both TEMs and ETG modes are linearly unstable, the effects of TEM-driven zonal flows on ETG turbulence were examined by means of entropy transfer analysis. In a statistically steady turbulence where the TEM driven zonal flows are dominant, it turned out that the zonal flows meditate the entropy transfer of the ETG modes from the low to high radial wavenumber regions. The successive entropy transfer broadens the potential fluctuation spectrum in the radial wavenumber direction. In contrast, in the situation where ETG modes are unstable but TEMs are stable, the pure ETG turbulence does not produce strong zonal flows, leading to a rather narrow spectrum in the radial wavenumber space and a higher transport level. (author)

  2. DECISIONS, METHODS AND TECHNIQUES RELATED TO DECISION SUPPORT SYSTEMS (DSS

    Directory of Open Access Journals (Sweden)

    Boghean Florin

    2015-07-01

    Full Text Available Generalised uncertainty, a phenomenon that today’s managers are facing as part of their professional experience, makes it impossible to anticipate the way the business environment will evolve or what will be the consequences of the decisions they plan to implement. Any decision making process within the company entails the simultaneous presence of a number of economic, technical, juridical, human and managerial variables. The development and the approval of a decision is the result of decision making activities developed by the decision maker and sometimes by a decision support team or/and a decision support system (DSS. These aspects related to specific applications of decision support systems in risk management will be approached in this research paper. Decisions in general and management decisions in particular are associated with numerous risks, due to their complexity and increasing contextual orientation. In each business entity, there are concerns with the implementation of risk management in order to improve the likelihood of meeting objectives, the trust of the parties involved, increase the operational safety and security as well as the protection of the environment, minimise losses, improve organisational resilience in order to diminish the negative impact on the organisation and provide a solid foundation for decision making. Since any business entity is considered to be a wealth generator, the analysis of their performance should not be restricted to financial efficiency alone, but will also encompass their economic efficiency as well. The type of research developed in this paper entails different dimensions: conceptual, methodological, as well as empirical testing. Subsequently, the conducted research entails a methodological side, since the conducted activities have resulted in the presentation of a simulation model that is useful in decision making processes on the capital market. The research conducted in the present paper

  3. Studies of osteoporosis in Singapore using isotope related technique

    International Nuclear Information System (INIS)

    Bose, K.; Goh, J.; Lee Soon Tai; Shamal Das De

    1996-01-01

    The main objectives of this study will be to determine the bone density in selected populations for the purposes of i)determining the age of peak bone mass in each study group and ii)quantifying the differences in bone density as functions of the age and sex of persons in the study group as well as quantifying the differences between study groups in different countries. Normal healthy subjects of both sexes across the age range of 15-50 will be recruited for this programme. There will be at least 15 subjects in each 5 year age range (i.e. a total of 105 subjects of each sex). The subjects will be of urban residency. The project will take a maximum of five years. Volunteers will be recruited from the hospital personnel and their friends and relatives. The subjects will be healthy individuals with no history of fractures and they should not be on any medication which may affect the bone density. A questionnaire regarding their lifestyle factors such as exercise, coffee/tea/alcohol intake and medication be filled. The subjects will also have X-rays of the dorsolumbar spine taken to ascertain the absence of scoliosis or crush fractures. Bone mineral density will be measured by dual energy X-ray absorptiometry using a Norland XR-26 bone densitometer. The BMD in the L2-L4 region of the lumbar spine and right hip which includes the femoral neck, trochanter and Ward's triangle will be scanned. Body composition will also be determined by doing a whole body scan on the subjects. Autopsy samples of rib bones from healthy accident victims in the age range 20-50 years will be obtained and the biomechanical strength of these bones will be tested. Biopsy specimens of the iliac crest will also be obtained to study the differences in trace element composition between osteoporotic patients and controls. (author)

  4. 2D Inversion of Transient Electromagnetic Method (TEM)

    Science.gov (United States)

    Bortolozo, Cassiano Antonio; Luís Porsani, Jorge; Acácio Monteiro dos Santos, Fernando

    2017-04-01

    A new methodology was developed for 2D inversion of Transient Electromagnetic Method (TEM). The methodology consists in the elaboration of a set of routines in Matlab code for modeling and inversion of TEM data and the determination of the most efficient field array for the problem. In this research, the 2D TEM modeling uses the finite differences discretization. To solve the inversion problem, were applied an algorithm based on Marquardt technique, also known as Ridge Regression. The algorithm is stable and efficient and it is widely used in geoelectrical inversion problems. The main advantage of 1D survey is the rapid data acquisition in a large area, but in regions with two-dimensional structures or that need more details, is essential to use two-dimensional interpretation methodologies. For an efficient field acquisition we used in an innovative form the fixed-loop array, with a square transmitter loop (200m x 200m) and 25m spacing between the sounding points. The TEM surveys were conducted only inside the transmitter loop, in order to not deal with negative apparent resistivity values. Although it is possible to model the negative values, it makes the inversion convergence more difficult. Therefore the methodology described above has been developed in order to achieve maximum optimization of data acquisition. Since it is necessary only one transmitter loop disposition in the surface for each series of soundings inside the loop. The algorithms were tested with synthetic data and the results were essential to the interpretation of the results with real data and will be useful in future situations. With the inversion of the real data acquired over the Paraná Sedimentary Basin (PSB) was successful realized a 2D TEM inversion. The results indicate a robust geoelectrical characterization for the sedimentary and crystalline aquifers in the PSB. Therefore, using a new and relevant approach for 2D TEM inversion, this research effectively contributed to map the most

  5. In situ TEM-tandem/implanter interface facility in Wuhan University for investigation of radiation effects

    International Nuclear Information System (INIS)

    Guo Liping; Li Ming; Liu Chuansheng; Song Bo; Ye Mingsheng; Fan Xiangjun; Fu Dejun

    2007-01-01

    Transmission electron microscope (TEM) interfaced to one or more ion implanters and/or accelerators, i.e. in situ TEM, provides effective tools to observe microstructural changes of studied samples during the ion irradiation. Evolution of both radiation damages and irradiation-induced nano-sized microstructures can be investigated with this technique, much more convenient than conventional ex situ techniques. In situ TEM technique has been widely applied in various fields, especially in the study of radiation damages of structural materials of fission and fusion nuclear reactors, and in evaluation and qualification of radioactive waste forms. Nowadays there are more than a dozen such facilities located in Japan, France, and the United States. Recently, we have constructed the first TEM-Tandem/Implanter interface facility of China in Wuhan University. A modified Hitachi H800 TEM was interfaced to a 200 kV ion implanter and a 2 x 1.7 MV tandem accelerator. Effective steps were taken to isolate the TEM from mechanical vibration from the ion beam line, and no obvious wobbling of the TEM image was observed during the ion implantation. The amorphization process of Si crystal irradiated by 115 keV N + ion beam was observed in the primary experiments, demonstrating that this interface facility is capable of in situ study of radiation effects. An online low energy gaseous ion source which may provide 1-20 keV H + and He + is under construction. (authors)

  6. TEM Imaging of Mass-selected Polymer Molecules

    International Nuclear Information System (INIS)

    Nasibulin, Albert G.; Kauppinen, Esko I.; Thomson, Bruce A.; Fernandez de la Mora, J.

    2002-01-01

    Polyethylene glycol (PEG) molecules with masses below 1300 amu are electrosprayed (ES) from solution, mobility-selected at high resolution in a differential mobility analyzer (DMA), collected on a grid and imaged by transmission electron microscopy (ES-DMA-TEM). The DMA resolves individual n-mers, and selects only one out of the many present in the original sample. Ion identity is established from parallel mass spectra (ES-MS). The images reveal spherical particles 1.46 nm in diameter, in good agreement with the known ion mass and bulk density. The DMA-selection technique opens new paths for the study of very small particles

  7. Proceedings of firsts workshop on Nuclear and related techniques in health

    International Nuclear Information System (INIS)

    1997-01-01

    The book presents papers submitted to the first Workshop on Nuclear and related techniques in health that was holder at the first International Symposium on Nuclear and Related Techniques in Agriculture, held in Havana, Cuba, on October 28 th and 30 th, 1997

  8. Use of the TEM Cell for Compliance Testing of Emissions and Immunity, an IEC Perspective

    DEFF Research Database (Denmark)

    Bentz, Sigurd

    1996-01-01

    The current work of the IEC on preparing a standard for the use of TEM cells for compliance testing of emissions and immunity is reviewed. The requirements of TEM cells are related to the established procedures: “open area test site” and “shielded enclosure with area of uniform field”, respective...

  9. Development of a versatile TEM specimen holder for the characterization of photocatalytic materials

    DEFF Research Database (Denmark)

    Cavalca, Filippo; Langhammer, C.; Hansen, Thomas Willum

    2011-01-01

    conventional TEM analysis on photocatalysts with several in situ TEM techniques including environmental TEM (ETEM), in situ photo activation and localized surface plasmon resonance (LSPR) spectroscopy [3-4]. These experiments are facilitated by the construction of a specimen holder capable of illuminating....../on nanomaterials and thin films. We present results from combined ETEM-LSPR studies of thermally-induced catalytic phenomena and on metal nanoparticle sintering, an important process in catalysis, which we study in situ in both real and model systems by means of indirect nanoplasmonic sensing and ETEM....

  10. The Use of Psychodrama Action Techniques in a Race Relations Class

    Science.gov (United States)

    Kranz, Peter L.; Ramirez, Sylvia Z.; Lund, Nick L.

    2007-01-01

    This article describes psychodrama action techniques that were effectively implemented in a university-level race relations course. Essential elements of these techniques included acting out and critical self-examination of the individual's personal beliefs. In a semi-structured class format in which uncensored spontaneity was stressed, students…

  11. TEMS: an alternative method for the repair of benign recto-vaginal fistulae.

    Science.gov (United States)

    Darwood, R J; Borley, N R

    2008-07-01

    The repair of high recto-vaginal fistula can be challenging since access may be limited via the endo-anal approach yet the alternative trans-abdominal route carries significant morbidity. We report the use of TEMS to repair a recto-vaginal fistula following anterior resection and pelvic radiotherapy. The patient was placed prone and a 25 cm rectoscope was inserted. A proximally based mucosal advancement flap was raised to repair the fistula. The patient was discharged 2 days later and a contrast study confirmed closure of the fistula. COMPARISON WITH OTHER TECHNIQUES: TEMS allows excellent visualisation of a rectovaginal fistula compared to standard endo-anal or trans-vaginal techniques. The morbidity is lower than the trans-abdominal route. TEMS is a useful technique for the repair of benign recto-vaginal fistula and has distinct advantages over conventional techniques.

  12. Environmental TEM in an Aberration Corrected Microscope

    DEFF Research Database (Denmark)

    Hansen, Thomas Willum; Wagner, Jakob Birkedal

    ‐resolution imaging. A gaseous atmosphere in the pole‐piece gap of the objective lens of the microscope alters both the incoming electron wave prior to interaction with the sample and the outgoing wave below the sample. Whereas conventional TEM samples are usually thin (below 10‐20 nm), the gas in the environmental...... the microscope column. The effects of gas on the electron wave in the objective lens are not well understood and needs further attention. Imaging samples with a simple geometry, such as gold particles on a flat graphene substrate and analyzing the variations in contrast, provides a means for understanding...... results from imaging in various elemental as well as di‐molecular gases and their effect on imaging and spectroscopy in the environmental transmission electron microscope....

  13. Strategies and techniques of communication and public relations applied to non-profit sector

    Directory of Open Access Journals (Sweden)

    Ioana – Julieta Josan

    2010-05-01

    Full Text Available The aim of this paper is to summarize the strategies and techniques of communication and public relations applied to non-profit sector.The approach of the paper is to identify the most appropriate strategies and techniques that non-profit sector can use to accomplish its objectives, to highlight specific differences between the strategies and techniques of the profit and non-profit sectors and to identify potential communication and public relations actions in order to increase visibility among target audience, create brand awareness and to change into positive brand sentiment the target perception about the non-profit sector.

  14. TEM investigations of microstructures of combustion aerosols

    International Nuclear Information System (INIS)

    Marquardt, A.; Hackfort, H.; Borchardt, J.; Schober, T.; Friedrich, J.

    1992-12-01

    In the incineration of organic material, apart from a series of gaseous pollutants, particulate pollutants or combustion aerosols also arise. The latter frequently consist of particles with a solid core of carbon to which a large number of inorganic and organic compounds are attached. These primarily include the polycyclic aromatic hydrocarbons (PAH) and their nitro-derivatives (NPAH), whose mutagenic or carcinogenic effect is known. The invisible particle sizes in the nanometer range, whose retention in the incineration off-gas is not state of the art, are of increasing significance for man and environment. On the one hand, they are deposited almost completely in the human lung. On the other hand, due to their fine dispersity they have along residence time in the atmosphere where they participate in chemical reactions and climatically significant processes. Important insights about the formation process of combustion aerosols are to be expected from the imaging of their microstructures in the transmission electron microscope (TEM). The present contribution describes the development and application of a representative sampling procedure for aerosols from a partial flow of flue gas from a fluidized-bed furnace. The method developed consists of electrically charging aerosol particles in situ and subsequently selectively precipitating them onto a microscope slide in an electric field. TEM studies of aerosol microstructures on the microscope slides revealed that in the combustion of petrol and heating oil under different combustion conditions in principle the same particle structures result, whereas in the incineration of used lubricating oil quite different particle structures were found. Results from the literature on aerosol microstructures in exhaust gases from petrol and diesel engines demonstrate agreement with the results of this study in the basic structure of the particles. (orig.) [de

  15. A new procedure for making TEM specimens of superconductor devices

    International Nuclear Information System (INIS)

    Huang, Y.; Merkle, K.L.

    1997-04-01

    A new procedure is developed for making TEM specimens of thin film devices. In this procedure the sample is flatly polished to an overall ion-mill-ready thickness so that any point in the 2-D sample pane can be thinned to an electron-transparent thickness by subsequent ion-milling. Using this procedure, small regions of interest can be easily reached in both cross-section and plan-view samples. This is especially useful in device studies. Applications of this procedure to the study of superconductor devices yield good results. This procedure, using commercially available equipment and relatively cheap materials, is simple and easy to realize

  16. A-10/TF34 Turbine Engine Monitoring System (TEMS)

    Science.gov (United States)

    Christopher, R. G.

    1981-01-01

    The hardware and software development of the A-10/TF34 turbine engine monitoring system (TEMS) is described. The operation and interfaces of the A-10/TF34 TEMS hardware are discussed with particular emphasis on function, capabilities, and limitations. The TEMS data types are defined and the various data acquisition modes are explained. Potential data products are also discussed.

  17. The application of nuclear and nuclear-related techniques for environmental pollution studies in Vietnam

    International Nuclear Information System (INIS)

    Nguyen Mong Sinh

    1992-01-01

    The applicability of neutron activation analysis, X-ray fluorescence and other related techniques to environmental samples from Viet Nam has been investigated. Results show that multielemental analysis of environmental samples and the determination of heavy metal pollution in the environment is best performed by a combination of techniques. Preliminary results of studying the environmental pollution associated with solid wastes are reported. 4 refs, 5 figs, 17 tabs

  18. SIZE OF BOEHMITE NANOPARTICLES BY TEM IMAGES ANALYSIS

    Directory of Open Access Journals (Sweden)

    Maxime Moreaud

    2011-05-01

    Full Text Available Transition aluminas, and especially the gamma type, are largely used as catalyst supports in refining and petrochemicals. Most studies focus on properties resulting from material texture and casting (specific surface, porous volume, pore shape and diameter. However, surface properties of alumina should be considered as well, as the catalytic activity is tightly related to the structure of exposed crystalline faces. As γ alumina results from controlled thermal treatment of boehmite γ-AlOOH by a topotactic transformation, the nature of exposed crystalline planes is related to the starting material. Therefore, the synthesis of the oxihydroxide γ-AlOOH, and especially size and shape of these particles, is critical in determining the relevant surface properties. Unlike often aggregated alumina, boehmite nanoparticles can be observed by TEM. Analysis of these TEM images can be performed to estimate the size of the boehmite nanoparticles. Information about morphology of the nanoparticles is obtained by the analysis of the covariance, modeling micrographs by a dilution model.

  19. PEDAGIGOCAL TECHNIQUE OF BUILDING THE CULTURE OF INTERPERSONAL RELATIONS IN PRESCHOOL CHILDREN AT ART CLASSES

    Directory of Open Access Journals (Sweden)

    Svetlana Vyacheslavovna Kahnovich

    2013-10-01

    Full Text Available The article looks at the pedagogical technique of building the culture of interpersonal relations in preschool children at the local and modular level. Interpersonal relations are viewed as the module and art classes as the local level. The research is timely as it can assist in studying the problem of moral development of preschool children by building the culture of interpersonal relations by artistic education means. The study presents novelty concluding from the survey of scientific literature. The process of building the culture of interpersonal relations in children has not been properly studied by preschool pedagogy. The task of the present study is to elaborate a pedagogical technique to build the culture of interpersonal relations between children at art classes. The article discusses ‘technological’ criteria (term by G.K. Selevko and presents interactive principles of the pedagogical technique. Group activities alongside with individual ones were viewed as organizational forms of art classes. Building the culture of interpersonal relations in preschool children at art classes is closely connected with the development of their personality, a child’s  consciousness, their motivational and conceptual spheres during their gradual moral development at various levels - emotional (attitude, axiological level, psychic (intentional cognitive processes, activity (artistic and interpersonal literacy. Graphic (projective methods were used to analyze age dynamics of ethical and moral development. The conclusion describes a set of pedagogical conditions for efficient building of the culture of interpersonal relations in children at art classes.  Goal. To elaborate a pedagogical technique for building the culture of interpersonal relations in preschool children at art classes. The technique can be applied at local and modular level.Methods and Methodology. The pedagogical technique is aimed at building the culture of interpersonal relations

  20. First Approximations of Prescribed Fire Risks Relative to Other Management Techniques Used on Private Lands.

    Directory of Open Access Journals (Sweden)

    Dirac Twidwell

    Full Text Available Fire is widely recognized as a critical ecological and evolutionary driver that needs to be at the forefront of land management actions if conservation targets are to be met. However, the prevailing view is that prescribed fire is riskier than other land management techniques. Perceived risks associated with the application of fire limits its use and reduces agency support for prescribed burning in the private sector. As a result, considerably less cost-share support is given for prescribed fire compared to mechanical techniques. This study tests the general perception that fire is a riskier technique relative to other land management options. Due to the lack of data available to directly test this notion, we use a combination of approaches including 1 a comparison of fatalities resulting from different occupations that are proxies for techniques employed in land management, 2 a comparison of fatalities resulting from wildland fire versus prescribed fire, and 3 an exploration of causal factors responsible for wildland fire-related fatalities. This approach establishes a first approximation of the relative risk of fatality to private citizens using prescribed fire compared to other management techniques that are readily used in ecosystem management. Our data do not support using risks of landowner fatalities as justification for the use of alternative land management techniques, such as mechanical (machine-related equipment, over prescribed fire. Vehicles and heavy machinery are consistently leading reasons for fatalities within occupations selected as proxies for management techniques employed by ranchers and agricultural producers, and also constitute a large proportion of fatalities among firefighters. Our study provides the foundation for agencies to establish data-driven decisions regarding the degree of support they provide for prescribed burning on private lands.

  1. Characterization of crystallite morphology for doped strontium fluoride nanophosphors by TEM and XRD

    Energy Technology Data Exchange (ETDEWEB)

    O' Connell, J.H. [Centre for HRTEM, Nelson Mandela Metropolitan University, PO Box 77000, Port Elizabeth ZA6031 (South Africa); Lee, M.E., E-mail: Michael.lee@nmmu.ac.za [Centre for HRTEM, Nelson Mandela Metropolitan University, PO Box 77000, Port Elizabeth ZA6031 (South Africa); Yagoub, M.Y.A.; Swart, H.C.; Coetsee, E. [Department of Physics, University of the Free State, PO Box 339, Bloemfontein ZA9300 (South Africa)

    2016-01-01

    Crystallite morphology for Eu-doped and undoped SrF{sub 2} nanophosphors have been determined by X-ray diffraction (XRD) and transmission electron microscopy (TEM). The values for average crystallite size obtained by the application of the Scherrer equation and the full width at half maximum (FWHM) values for XRD peaks are compared to the results obtained using the hollow cone dark field (HCDF) TEM imaging technique. In the case of the TEM analysis, a bimodal crystallite size distribution was revealed with one of the distributions having a measured range of crystallite sizes which was in good agreement with the XRD data. HCDF in combination with FIB specimen preparation was found to be a promising technique for the determination of crystallite size distributions in nanophosphors which might facilitate a better understanding of their scintillation properties.

  2. Characterization of crystallite morphology for doped strontium fluoride nanophosphors by TEM and XRD

    International Nuclear Information System (INIS)

    O'Connell, J.H.; Lee, M.E.; Yagoub, M.Y.A.; Swart, H.C.; Coetsee, E.

    2016-01-01

    Crystallite morphology for Eu-doped and undoped SrF_2 nanophosphors have been determined by X-ray diffraction (XRD) and transmission electron microscopy (TEM). The values for average crystallite size obtained by the application of the Scherrer equation and the full width at half maximum (FWHM) values for XRD peaks are compared to the results obtained using the hollow cone dark field (HCDF) TEM imaging technique. In the case of the TEM analysis, a bimodal crystallite size distribution was revealed with one of the distributions having a measured range of crystallite sizes which was in good agreement with the XRD data. HCDF in combination with FIB specimen preparation was found to be a promising technique for the determination of crystallite size distributions in nanophosphors which might facilitate a better understanding of their scintillation properties.

  3. Demonstration of relatively new electron dosimetry measurement techniques on the Mevatron 80

    International Nuclear Information System (INIS)

    Meyer, J.A.; Palta, J.R.; Hogstrom, K.R.

    1984-01-01

    A comprehensive set of electron dosimetry measurements at 7, 10, 12, 15, and 18 MeV was made on a Mevatron 80. Dosimetry measurements presented include percentage depth dose, dose in the buildup region, field size dependence of output, output at extended distances, lead transmission measurements, and isodose curves. These beam measurements are presented to document the electron beam characteristics of this linear accelerator. Three relatively new dosimetry techniques, which have not been standardly used in the past, are illustrated. One technique determines the depth dose of fields too small to measure. A second technique accurately converts depth dose measured in polystyrene to depth dose in water. A third technique calculates the output at extended distances

  4. A spatial compression technique for head-related transfer function interpolation and complexity estimation

    DEFF Research Database (Denmark)

    Shekarchi, Sayedali; Christensen-Dalsgaard, Jakob; Hallam, John

    2015-01-01

    A head-related transfer function (HRTF) model employing Legendre polynomials (LPs) is evaluated as an HRTF spatial complexity indicator and interpolation technique in the azimuth plane. LPs are a set of orthogonal functions derived on the sphere which can be used to compress an HRTF dataset...

  5. Pollen of Sarawakodendron (Celastraceae) and some related genera, with notes on techniques

    NARCIS (Netherlands)

    Hou, Ding

    1969-01-01

    1. A simple technique for acetolysis of small quantities of polliniferous (herbarium) material is described and notes on pollen photomicrography are presented. 2. Pollen grains of Sarawakodendron and six related genera, consisting of twenty-nine mostly Malesian species, have been examined and

  6. Side effects after radiotherapy of age-related macular degeneration with the Nijmegen technique.

    NARCIS (Netherlands)

    Hoyng, C.B.; Tromp, A.I.; Meulendijks, C.F.M.; Leys, A.; Maazen, R.W.M. van der; Deutman, A.F.; Vingerling, J.R.

    2002-01-01

    BACKGROUND: In a randomized trial concerning radiotherapy for age-related macular degeneration, fluorescein angiograms were taken of controls and patients. In this study the frequency of side effects in eyes receiving radiotherapy with the Nijmegen technique is compared with the findings in the eyes

  7. Determination of Morphological Parameters of Supported Gold Nanoparticles: Comparison of AFM Combined with Optical Spectroscopy and Theoretical Modeling versus TEM

    Directory of Open Access Journals (Sweden)

    Frank Hubenthal

    2012-07-01

    Full Text Available The morphology of small gold particles prepared by Volmer–Weber growth on sapphire substrates have been investigated by two different characterization techniques. First, by non-extensive atomic force microscopy (AFM in combination with optical spectroscopy and modeling of the optical properties using a theoretical model, recently developed in our group. Second, by extensive transmission electron microscopy (TEM. Comparing the results obtained with both techniques demonstrate that for small gold nanoparticles within the quasistatic limit, the morphological properties can be precisely determined by an appropriate theoretical modeling of the optical properties in combination with simple AFM measurements. The apparent mean axial ratio of the nanoparticles, i.e., the axial ratio that corresponds to the center frequency of the ensemble plasmon resonance, is obtained easily from the extinction spectrum. The mean size is determined by the nanoparticle number density and the amount of deposited material, measured by AFM and a quartz micro balance, respectively. To extract the most probable axial ratio of the nanoparticle ensemble, i.e., the axial ratio that corresponds to the most probable nanoparticle size in the ensemble, we apply the new theoretical model, which allows to extract the functional dependence of the nanoparticle shape on its size. The morphological parameters obtained with this procedure will be afterwards compared to extensive TEM measurements. The results obtained with both techniques yield excellent agreement. For example, the lateral dimensions of the nanoparticles after deposition of 15.2 × 1015 atoms/cm2 of gold has been compared. While a mean lateral diameter of (13 ± 2 nm has been extracted from AFM, optical spectroscopy and modeling, a value of (12 ± 2 nm is derived from TEM. The consistency of the results demonstrate the precision of our new model. Moreover, since our theoretical model allows to extract the functional

  8. Quantitative phase imaging and differential interference contrast imaging for biological TEM

    International Nuclear Information System (INIS)

    Allman, B.E.; McMahon, P.J.; Barone-Nugent, E.D.; Nugent, E.D.

    2002-01-01

    Full text: Phase microscopy is a central technique in science. An experienced microscopist uses this effect to visualise (edge) structure within transparent samples by slightly defocusing the microscope. Although widespread in optical microscopy, phase contrast transmission electron microscopy (TEM) has not been widely adopted. TEM for biological specimens has largely relied on staining techniques to yield sufficient contrast. We show here a simple method for quantitative TEM phase microscopy that quantifies this phase contrast effect. Starting with conventional, digital, bright field images of the sample, our algorithm provides quantitative phase information independent of the sample's bright field intensity image. We present TEM phase images of a range of stained and unstained, biological and material science specimens. This independent phase and intensity information is then used to emulate a range of phase visualisation images familiar to optical microscopy, e.g. differential interference contrast. The phase images contain features not visible with the other imaging modalities. Further, if the TEM samples have been prepared on a microtome to a uniform thickness, the phase information can be converted into refractive index structure of the specimen. Copyright (2002) Australian Society for Electron Microscopy Inc

  9. TEM1 expression in cancer-associated fibroblasts is correlated with a poor prognosis in patients with gastric cancer

    International Nuclear Information System (INIS)

    Fujii, Satoshi; Fujihara, Ayano; Natori, Kei; Abe, Anna; Kuboki, Yasutoshi; Higuchi, Youichi; Aizawa, Masaki; Kuwata, Takeshi; Kinoshita, Takahiro; Yasui, Wataru; Ochiai, Atsushi

    2015-01-01

    The cancer stroma, including cancer-associated fibroblasts (CAFs), is known to contribute to cancer cell progression and metastasis, suggesting that functional proteins expressed specifically in CAFs might be candidate molecular targets for cancer treatment. The purpose of the present study was to explore the possibility of using TEM1 (tumor endothelial marker 1), which is known to be expressed in several types of mesenchymal cells, as a molecular target by examining the impact of TEM1 expression on clinicopathological factors in gastric cancer patients. A total of 945 consecutive patients with gastric cancer who underwent surgery at the National Cancer Center Hospital East between January 2003 and July 2007 were examined using a tissue microarray approach. TEM1 expression in CAFs or vessel-associated cells was determined using immunohistochemical staining. Three items (CAF-TEM1-positivity, CAF-TEM1-intensity, and vessel-TEM1-intensity) were then examined to determine the correlations between the TEM1 expression status and the recurrence-free survival (RFS), overall survival (OS), cancer-related survival (COS), and other clinicopathological factors. Significant correlations between CAF-TEM1-positivity or CAF-TEM1-intensity and RFS, OS, or COS were observed (P < 0.001, Kaplan–Meier curves); however, no significant correlation between vessel-TEM1-intensity and RFS, OS, or COS was observed. A univariate analysis showed that CAF-TEM1-positivity and CAF-TEM1-intensity were each correlated with a scirrhous subtype, tumor depth, nodal status, distant metastasis, serosal invasion, lymphatic or venous vessel infiltrations, and pTMN stage. This study suggests that the inhibition of TEM1 expression specifically in the CAFs of gastric carcinoma might represent a new strategy for the treatment of gastric cancer

  10. Tourism Employment Module (TEM: Case of the Czech Republic

    Directory of Open Access Journals (Sweden)

    Zdeněk Lejsek

    2011-09-01

    Full Text Available Tourism Employment Module (TEM provides information on the significance and contribution of tourism for the national economy in terms of employment. It refers to a system of tables describing the main economic characteristics of tourism (i.e. number of jobs and people employed in tourism by industry, seasonality, working scheme,permanency of job, sex, age groups, level of education or nationality and classifying thereby tourism as one of branches in the system of national accounts. The article describes basic methodological concept and structure of this tool (and approaches to measuring employment in the tourist industry in general, exploited data sources and provides a brief information on the type and form of publishing of the results as well as the data on principalmacroeconomic indicators of tourism-related industries in the Czech Republic in 2003–2009.

  11. A tem investigation on intermetallic particles in zircaloy-2

    International Nuclear Information System (INIS)

    Sudarminto, Harini Sosiati; Kuwano, Noriyuki; Oki, Kensuke

    1996-01-01

    Tem investigation were conducted on the heat treated zircaloy-2 having the composition of Zr containing 1.6% Sn, 0.2% Fe, 0.1% Cr and 0.05% Ni (%wt) in order tostudy the characteristics of intermetallic particles related to the microstructural basis on the corrosion effect. Forged zircaloy-2 was annealed in the β-phase at 1050 C degrees for various isothermally in the α-phase region at 650 and 750 C degrees, followed by water quenching. The size precipates, the lower became their number. By increasing the annealing temperature, the growth of precipitates formed in this zircaloy-2 were of the Zr(Cr,Fe) 2 and Zr 2 (Fe,Cr,Ni) types. These kinds of precipitates and the ratios of Fe/Cr were independent of size and shape of precipitates and annealing time and temperature. (author), 16 refs, 2 tabs, 5 figs

  12. Experimental study on propagation properties of large size TEM antennas

    International Nuclear Information System (INIS)

    Zhang Guowei; Wang Haiyang; Chen Weiqing; Wang Wei; Zhu Xiangqin; Xie Linshen

    2014-01-01

    The propagation properties of large size TEM antennas were studied by experiment. The size of the TEM antennas is 60 m × 20 m × 10 m and the character Impedance is 120 Ω. A kind of dielectric foil switch is designed compactly with TEM antennas which can generate double exponential waveform with altitude of 10 kV and rise time of l.2 ns. The radiated field distribution was measured. The relationship between rise time/altitude and distance were provided, and the propagation properties of large size TEM antennas were summarized. (authors)

  13. SANS and TEM studies of carbide precipitation and creep damage in type 304 stainless steel

    International Nuclear Information System (INIS)

    Yoo, M.H.; Ogle, J.C.; Schneibel, J.H.; Swindeman, R.W.

    1984-01-01

    Small-angle neutron scattering (SANS) and transmission electron microscopy (TEM) studies were performed to characterize the carbide (M 23 C 6 ) precipitation and creep damage induced in type 304 stainless steel in the primary creep stage. The size distribution of matrix carbides evaluated from SANS analyses was consistent with TEM data, and the expected accelerated kinetics of precipitation under applied stress was confirmed. Additional SANS measurements after the postcreep solution annealing were made in order to differentiate cavities from the carbides. Potential advantages and difficulties associated with characterization of creep-induced cavitation by the SANS techniques are discussed

  14. Determination of Size Distributions in Nanocrystalline Powders by TEM, XRD and SAXS

    DEFF Research Database (Denmark)

    Jensen, Henrik; Pedersen, Jørgen Houe; Jørgensen, Jens Erik

    2006-01-01

    Crystallite size distributions and particle size distributions were determined by TEM, XRD, and SAXS for three commercially available TiO2 samples and one homemade. The theoretical Guinier Model was fitted to the experimental data and compared to analytical expressions. Modeling of the XRD spectra...... the size distribution obtained from the XRD experiments; however, a good agreement was obtained between the two techniques. Electron microscopy, SEM and TEM, confirmed the primary particle sizes, the size distributions, and the shapes obtained by XRD and SAXS. The SSEC78 powder and the commercially...

  15. Present status and future prospects of spherical aberration corrected TEM/STEM for study of nanomaterials

    International Nuclear Information System (INIS)

    Tanaka, Nobuo

    2008-01-01

    The present status of Cs-corrected TEM/STEM is described from the viewpoint of the observation of nanomaterials. Characteristic features in TEM and STEM are explained using the experimental data obtained by our group and other research groups. Cs correction up to the 3rd-order aberration of an objective lens has already been established and research interest is focused on correcting the 5th-order spherical aberration and the chromatic aberration in combination with the development of a monochromator below an electron gun for smaller point-to-point resolution in optics. Another fundamental area of interest is the limitation of TEM and STEM resolution from the viewpoint of the scattering of electrons in crystals. The minimum size of the exit-wave function below samples undergoing TEM imaging is determined from the calculation of scattering around related atomic columns in the crystals. STEM does not have this limitation because the resolution is, in principle, determined by the probe size. One of the future prospects of Cs-corrected TEM/STEM is the possibility of extending the space around the sample holder by correcting the chromatic and spherical aberrations. This wider space will contribute to the ease of performing in situ experiments and various combinations of TEM and other analysis methods. High-resolution, in situ dynamic and 3D observations/analysis are the most important keywords in the next decade of high-resolution electron microscopy. (topical review)

  16. Proceedings of Fifth International Symposium on Nuclear and Related Techniques NURT 2006

    International Nuclear Information System (INIS)

    2006-04-01

    The Cd-Rom presents papers submitted to the Fifth International Symposium on Nuclear and Related Techniques NURT 2006 held in Havana, Cuba, on April, 2006. The NURT Symposia are one of the key Cuban scientific meetings dealing with the peaceful applications of nuclear techniques in all domains of the society. They are arranged with a two-year frequency and provide a unique opportunity for the international scientific community to meet outstanding researches and to discuss current trends and task in several areas of applied, nuclear related topics. The first editions of the NURT were organized under the auspices of the International Atomic Energy Agency in 1997, 1999, 200, 2003 and hosted delegates and invited scientific from more than 40 countries from all over the world. The join several workshops, each one devoted to an specific field research

  17. Asian conference on x-rays and related techniques in research and industry. Proceedings

    International Nuclear Information System (INIS)

    1996-01-01

    This proceedings compile the paper presented at the conference. The papers for presentation are from wide spectrum stressing the interdisciplinary nature of the conference i.e. x-ray fluorescence spectrometry (XRF), x-ray diffraction (XRD), TEM, scanning electron microscope (SEM), energy dispersive x-ray (EDX), auger electron microscopy, electron back scatter diffraction (EBSD)

  18. LENR BEC Clusters on and below Wires through Cavitation and Related Techniques

    Science.gov (United States)

    Stringham, Roger; Stringham, Julie

    2011-03-01

    During the last two years I have been working on BEC cluster densities deposited just under the surface of wires, using cavitation, and other techniques. If I get the concentration high enough before the clusters dissipate, in addition to cold fusion related excess heat (and other effects, including helium-4 formation) I anticipate that it may be possible to initiate transient forms of superconductivity at room temperature.

  19. Quantitative TEM analysis of Al/Cu multilayer systems prepared by pulsed laser deposition

    DEFF Research Database (Denmark)

    Liu, Haihua; Pryds, Nini; Schou, Jørgen

    2010-01-01

    Thin films composed of alternating Al/Cu/Al layers were deposited on a (111) Si substrate using pulsed laser deposition (PLD). The thicknesses of the film and the individual layers, and the detailed internal structure within the layers were characterized by means of transmission electron microscopy...... for the formation of the first layer of nano-sized Al grains. The results demonstrate that the PLD technique is a powerful tool to produce nano-scale multilayered metal films with controllable thickness and grain sizes....... (TEM), high-resolution TEM (HRTEM), and energy-filtered TEM (EFTEM). Each Al or Cu layer consists of a single layer of nano-sized grains of different orientations. EFTEM results revealed a layer of oxide about 2 nm thick on the surface of the Si substrate, which is considered to be the reason...

  20. It's not hype, it's communication: Using public relations techniques to improve your technical messages

    Energy Technology Data Exchange (ETDEWEB)

    Martell, P.J.

    1990-01-01

    Technical communicators are concerned that if they employ public relations (PR) techniques, they somehow compromise their work. They believe PR equates with type. However, to those of us in the field, PR means simply how people relate. Knowing PR techniques gives one a better understanding of human factors and interactions; using the techniques improves the chances for communication to occur. If technical communications are willing to learn PR techniques, they will gain strong tools to use to strengthen their messages.

  1. In-situ TEM Studies : Heat-treatment and Corrosion

    NARCIS (Netherlands)

    Malladi, S.R.K.

    2014-01-01

    Transmission electron microscopy (TEM) has been well known as a powerful characterisation tool to understand the structure and composition of various materials down to the atomic level. Over the years, several TEM studies have been carried out to understand the compositional, structural and

  2. Focus-variation image reconstruction in field-emission TEM

    NARCIS (Netherlands)

    Coene, W.M.J.; Janssen, A.J.E.M.; Op de Beeck, M.; Van Dyck, D.; Van Zwet, E.J.; Zandbergen, H.W.; Bailey, G.W.; Rieder, C.L.

    1993-01-01

    The use of a field emission gun (FEG) in high resolution TEM (HRTEM) improves the information limit much below the point resolution. In the area between point and information resolution of the FEG-TEM, image interpretation is complicated by the lens aberrations and focus effects. Different

  3. Evaluation of relative radiometric correction techniques on Landsat 8 OLI sensor data

    Science.gov (United States)

    Novelli, Antonio; Caradonna, Grazia; Tarantino, Eufemia

    2016-08-01

    The quality of information derived from processed remotely sensed data may depend upon many factors, mostly related to the extent data acquisition is influenced by atmospheric conditions, topographic effects, sun angle and so on. The goal of radiometric corrections is to reduce such effects in order enhance the performance of change detection analysis. There are two approaches to radiometric correction: absolute and relative calibrations. Due to the large amount of free data products available, absolute radiometric calibration techniques may be time consuming and financially expensive because of the necessary inputs for absolute calibration models (often these data are not available and can be difficult to obtain). The relative approach to radiometric correction, known as relative radiometric normalization, is preferred with some research topics because no in situ ancillary data, at the time of satellite overpasses, are required. In this study we evaluated three well known relative radiometric correction techniques using two Landsat 8 - OLI scenes over a subset area of the Apulia Region (southern Italy): the IR-MAD (Iteratively Reweighted Multivariate Alteration Detection), the HM (Histogram Matching) and the DOS (Dark Object Subtraction). IR-MAD results were statistically assessed within a territory with an extremely heterogeneous landscape and all computations performed in a Matlab environment. The panchromatic and thermal bands were excluded from the comparisons.

  4. Atom-counting in High Resolution Electron Microscopy:TEM or STEM - That's the question.

    Science.gov (United States)

    Gonnissen, J; De Backer, A; den Dekker, A J; Sijbers, J; Van Aert, S

    2017-03-01

    In this work, a recently developed quantitative approach based on the principles of detection theory is used in order to determine the possibilities and limitations of High Resolution Scanning Transmission Electron Microscopy (HR STEM) and HR TEM for atom-counting. So far, HR STEM has been shown to be an appropriate imaging mode to count the number of atoms in a projected atomic column. Recently, it has been demonstrated that HR TEM, when using negative spherical aberration imaging, is suitable for atom-counting as well. The capabilities of both imaging techniques are investigated and compared using the probability of error as a criterion. It is shown that for the same incoming electron dose, HR STEM outperforms HR TEM under common practice standards, i.e. when the decision is based on the probability function of the peak intensities in HR TEM and of the scattering cross-sections in HR STEM. If the atom-counting decision is based on the joint probability function of the image pixel values, the dependence of all image pixel intensities as a function of thickness should be known accurately. Under this assumption, the probability of error may decrease significantly for atom-counting in HR TEM and may, in theory, become lower as compared to HR STEM under the predicted optimal experimental settings. However, the commonly used standard for atom-counting in HR STEM leads to a high performance and has been shown to work in practice. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. "One-sample concept" micro-combinatory for high throughput TEM of binary films.

    Science.gov (United States)

    Sáfrán, György

    2018-04-01

    Phases of thin films may remarkably differ from that of bulk. Unlike to the comprehensive data files of Binary Phase Diagrams [1] available for bulk, complete phase maps for thin binary layers do not exist. This is due to both the diverse metastable, non-equilibrium or instable phases feasible in thin films and the required volume of characterization work with analytical techniques like TEM, SAED and EDS. The aim of the present work was to develop a method that remarkably facilitates the TEM study of the diverse binary phases of thin films, or the creation of phase maps. A micro-combinatorial method was worked out that enables both preparation and study of a gradient two-component film within a single TEM specimen. For a demonstration of the technique thin Mn x Al 1- x binary samples with evolving concentration from x = 0 to x = 1 have been prepared so that the transition from pure Mn to pure Al covers a 1.5 mm long track within the 3 mm diameter TEM grid. The proposed method enables the preparation and study of thin combinatorial samples including all feasible phases as a function of composition or other deposition parameters. Contrary to known "combinatorial chemistry", in which a series of different samples are deposited in one run, and investigated, one at a time, the present micro-combinatorial method produces a single specimen condensing a complete library of a binary system that can be studied, efficiently, within a single TEM session. That provides extremely high throughput for TEM characterization of composition-dependent phases, exploration of new materials, or the construction of phase diagrams of binary films. Copyright © 2018 Elsevier B.V. All rights reserved.

  6. GISAXS modelling of helium-induced nano-bubble formation in tungsten and comparison with TEM

    International Nuclear Information System (INIS)

    Thompson, Matt; Sakamoto, Ryuichi; Bernard, Elodie; Kirby, Nigel; Kluth, Patrick; Riley, Daniel; Corr, Cormac

    2016-01-01

    Grazing-incidence small angle x-ray scattering (GISAXS) is a powerful non-destructive technique for the measurement of nano-bubble formation in tungsten under helium plasma exposure. Here, we present a comparative study between transmission electron microscopy (TEM) and GISAXS measurements of nano-bubble formation in tungsten exposed to helium plasma in the Large Helical Device (LHD) fusion experiment. Both techniques are in excellent agreement, suggesting that nano-bubbles range from spheroidal to ellipsoidal, displaying exponential diameter distributions with mean diameters μ=0.68 ± 0.04 nm and μ=0.6 ± 0.1 nm measured by TEM and GISAXS respectively. Depth distributions were also computed, with calculated exponential depth distributions with mean depths of 8.4 ± 0.5 nm and 9.1 ± 0.4 nm for TEM and GISAXS. In GISAXS modelling, spheroidal particles were fitted with an aspect ratio ε=0.7 ± 0.1. The GISAXS model used is described in detail. - Highlights: • GISAXS and TEM were used to measure nano-bubble formation in W exposed to He plasma in the large helical device. • Nano-bubbles had an exponential diameter distributions with averages 0.6 ± 0.1 nm and 0.68 ± 0.04 nm measured by GISAXS and TEM. • Nano-bubbles had an exponential depth distributions with average depths of 9.1 ± 0.4 nm and 8.4 ± 0.5 nm for GISAXS and TEM. • The GISAXS model used to analyse diffraction patterns is explained in detail.

  7. GISAXS modelling of helium-induced nano-bubble formation in tungsten and comparison with TEM

    Energy Technology Data Exchange (ETDEWEB)

    Thompson, Matt, E-mail: matt.a.thompson@anu.edu.au [Research School of Physics and Engineering, Australian National University, Mills Road, Acton, ACT 2601 (Australia); Sakamoto, Ryuichi [National Institute for Fusion Science, Toki, Gifu 509-5292 (Japan); Bernard, Elodie [Aix-Marseille University, Marseille 13288 (France); Kirby, Nigel [SAXS/WAXS Beamline, Australian Synchrotron, 800 Blackburn Rd, Clayton, VIC, 3168 (Australia); Kluth, Patrick [Research School of Physics and Engineering, Australian National University, Mills Road, Acton, ACT 2601 (Australia); Riley, Daniel [Australian Nuclear Science and Technology Organisation, Locked Bag 2001, Kirrawee DC, NSW, 2232 (Australia); Corr, Cormac [Research School of Physics and Engineering, Australian National University, Mills Road, Acton, ACT 2601 (Australia)

    2016-05-15

    Grazing-incidence small angle x-ray scattering (GISAXS) is a powerful non-destructive technique for the measurement of nano-bubble formation in tungsten under helium plasma exposure. Here, we present a comparative study between transmission electron microscopy (TEM) and GISAXS measurements of nano-bubble formation in tungsten exposed to helium plasma in the Large Helical Device (LHD) fusion experiment. Both techniques are in excellent agreement, suggesting that nano-bubbles range from spheroidal to ellipsoidal, displaying exponential diameter distributions with mean diameters μ=0.68 ± 0.04 nm and μ=0.6 ± 0.1 nm measured by TEM and GISAXS respectively. Depth distributions were also computed, with calculated exponential depth distributions with mean depths of 8.4 ± 0.5 nm and 9.1 ± 0.4 nm for TEM and GISAXS. In GISAXS modelling, spheroidal particles were fitted with an aspect ratio ε=0.7 ± 0.1. The GISAXS model used is described in detail. - Highlights: • GISAXS and TEM were used to measure nano-bubble formation in W exposed to He plasma in the large helical device. • Nano-bubbles had an exponential diameter distributions with averages 0.6 ± 0.1 nm and 0.68 ± 0.04 nm measured by GISAXS and TEM. • Nano-bubbles had an exponential depth distributions with average depths of 9.1 ± 0.4 nm and 8.4 ± 0.5 nm for GISAXS and TEM. • The GISAXS model used to analyse diffraction patterns is explained in detail.

  8. Processing grounded-wire TEM signal in time-frequency-pseudo-seismic domain: A new paradigm

    Science.gov (United States)

    Khan, M. Y.; Xue, G. Q.; Chen, W.; Huasen, Z.

    2017-12-01

    Grounded-wire TEM has received great attention in mineral, hydrocarbon and hydrogeological investigations for the last several years. Conventionally, TEM soundings have been presented as apparent resistivity curves as function of time. With development of sophisticated computational algorithms, it became possible to extract more realistic geoelectric information by applying inversion programs to 1-D & 3-D problems. Here, we analyze grounded-wire TEM data by carrying out analysis in time, frequency and pseudo-seismic domain supported by borehole information. At first, H, K, A & Q type geoelectric models are processed using a proven inversion program (1-D Occam inversion). Second, time-to-frequency transformation is conducted from TEM ρa(t) curves to magneto telluric MT ρa(f) curves for the same models based on all-time apparent resistivity curves. Third, 1-D Bostick's algorithm was applied to the transformed resistivity. Finally, EM diffusion field is transformed into propagating wave field obeying the standard wave equation using wavelet transformation technique and constructed pseudo-seismic section. The transformed seismic-like wave indicates that some reflection and refraction phenomena appear when the EM wave field interacts with geoelectric interface at different depth intervals due to contrast in resistivity. The resolution of the transformed TEM data is significantly improved in comparison to apparent resistivity plots. A case study illustrates the successful hydrogeophysical application of proposed approach in recovering water-filled mined-out area in a coal field located in Ye county, Henan province, China. The results support the introduction of pseudo-seismic imaging technology in short-offset version of TEM which can also be an useful aid if integrated with seismic reflection technique to explore possibilities for high resolution EM imaging in future.

  9. Mechanical Conversion for High-Throughput TEM Sample Preparation

    International Nuclear Information System (INIS)

    Kendrick, Anthony B; Moore, Thomas M; Zaykova-Feldman, Lyudmila

    2006-01-01

    This paper presents a novel method of direct mechanical conversion from lift-out sample to TEM sample holder. The lift-out sample is prepared in the FIB using the in-situ liftout Total Release TM method. The mechanical conversion is conducted using a mechanical press and one of a variety of TEM coupons, including coupons for both top-side and back-side thinning. The press joins a probe tip point with attached TEM sample to the sample coupon and separates the complete assembly as a 3mm diameter TEM grid, compatible with commercially available TEM sample holder rods. This mechanical conversion process lends itself well to the high through-put requirements of in-line process control and to materials characterization labs where instrument utilization and sample security are critically important

  10. Predictable Technique to Register Retruded Contact Position (RCP) Using a Disposable Jaw Relation Recording Device.

    Science.gov (United States)

    Daher, Tony; Lobel, William A; Massad, Joseph; Ahuja, Swati; Danilov, Zarko Jack

    2015-05-01

    The dental literature presents various definitions and techniques to describe and register centric relation (CR) or centric occlusion (CO). Briefly reviewing the literature in relation to CR, this article proposes the use of the term retruded contact position (RCP), clinically defined as retruded, unstrained, repeatable position and where the mandibular movements start when a Gothic arch tracing is used. With this clinical definition, a technique can be easily selected that meets all the requirements of such position. The article discusses the use of a jaw recorder that is an intraorally graphic recording device that results in a tracing of mandibular movements in one plane, with the apex of the tracing indicating the retruded, unstrained, and repeatable relationship. The intersection of the arcs produced by the right and left working movement form the apex of the Gothic arch tracing. Several clinical situations using the jaw recorder are described. Clinicians can now quickly and accurately record RCP, balance complete, partial, or implant dentures, and orthopedically reposition the mandible. The technique achieves highly reliable and reproducible results.

  11. Applied research on air pollution using nuclear-related analytical techniques

    International Nuclear Information System (INIS)

    1994-01-01

    A co-ordinated research programme (CRP) on applied research on air pollution using nuclear-related techniques is a global CRP which will run from 1992-1996, and will build upon the experience gained by the Agency from the laboratory support that it has been providing for several years to BAPMoN - the Background Air Pollution Monitoring Network programme organized under the auspices of the World Meterological Organization. The purpose of this CRP is to promote the use of nuclear analytical techniques in air pollution studies, e.g. NAA, XFR, and PIXE for the analysis of toxic and other trace elements in suspended particulate matter (including air filter samples), rainwater and fog-water samples, and in biological indicators of air pollution (e.g. lichens and mosses). The main purposes of the core programme are i) to support the use of nuclear and nuclear-related analytical techniques for practically-oriented research and monitoring studies on air pollution ii) to identify major sources of air pollution affecting each of the participating countries with particular reference to toxic heavy metals, and iii) to obtain comparative data on pollution levels in areas of high pollution (e.g. a city centre or a populated area downwind of a large pollution source) and low pollution (e.g. rural areas). This document reports the discussions held during the first Research Co-ordination Meeting (RCM) for the CRP which took place at the IAEA Headquarters in Vienna. Refs, figs and tabs

  12. Harmonization of health related environmental measurements using nuclear and isotopic techniques. Proceedings of an international symposium

    International Nuclear Information System (INIS)

    1997-01-01

    One of the particular strengths of nuclear methods is in analytical quality assurance, including the validation of analytical methods and the development of new analytical reference materials. These methodologies are therefore helping to harmonize the data produced not only by nuclear techniques themselves, but also by other non-nuclear methods of analysis. The aim of this symposium was to provide an international forum for discussion of these topics. Its programme covered a wide variety of applications of nuclear (and related) analytical techniques (mainly neutron activation analysis, energy dispersive X ray fluorescence, particle induced X ray emission and inductively coupled plasma-mass spectrometry) as used in the study of air particulates, solid waste products, sediments, food, water, human tissues, biomonitors and other kinds of environmental samples

  13. Novel sample preparation for operando TEM of catalysts

    International Nuclear Information System (INIS)

    Miller, Benjamin K.; Barker, Trevor M.; Crozier, Peter A.

    2015-01-01

    A new TEM sample preparation method is developed to facilitate operando TEM of gas phase catalysis. A porous Pyrex-fiber pellet TEM sample was produced, allowing a comparatively large amount of catalyst to be loaded into a standard Gatan furnace-type tantalum heating holder. The increased amount of catalyst present inside the environmental TEM allows quantitative determination of the gas phase products of a catalytic reaction performed in-situ at elevated temperatures. The product gas concentration was monitored using both electron energy loss spectroscopy (EELS) and residual gas analysis (RGA). Imaging of catalyst particles dispersed over the pellet at atomic resolution is challenging, due to charging of the insulating glass fibers. To overcome this limitation, a metal grid is placed into the holder in addition to the pellet, allowing catalyst particles dispersed over the grid to be imaged, while particles in the pellet, which are assumed to experience identical conditions, contribute to the overall catalytic conversion inside the environmental TEM cell. The gas within the cell is determined to be well-mixed, making this assumption reasonable. - Highlights: • High in-situ conversion of CO to CO 2 achieved by a novel TEM sample preparation method. • A 3 mm fiber pellet increases the TEM sample surface area by 50×. • Operando atomic resolution is maintained by also including a 3 mm grid in the sample. • Evidence for a well-mixed gas composition inside the ETEM cell is given

  14. Soft nanomaterials analysed by in situ liquid TEM: Towards high resolution characterisation of nanoparticles in motion

    Directory of Open Access Journals (Sweden)

    Joseph P. Patterson

    2015-12-01

    Full Text Available In this article we present in situ transmission electron microscopy (TEM of soft, synthetic nanoparticles with a comparative analysis using conventional TEM methods. This comparison is made with the simple aim of describing what is an unprecedented example of in situ imaging by TEM. However, we contend the technique will quickly become essential in the characterisation of analogous systems, especially where dynamics are of interest in the solvated state. In this case, particles were studied which were obtained from the direct polymerisation of an oxaliplatin analogue, designed for an ongoing programme in novel chemotherapeutic delivery systems. The resulting nanoparticles provided sufficient contrast for facile imaging in situ, and point towards key design parameters that enable this new characterisation approach for organic nanomaterials. We describe the preparation of the synthetic nanoparticles together with their characterisation in liquid water. Finally, we provide a future perspective of this technique for the analysis of soft and dynamic nanomaterials and discussion the progress which needs to be made in order to bring in situ liquid TEM to its full potential.

  15. Proceedings of the 13th meeting for tandem accelerators and related techniques

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-02-01

    The 13th Meeting for Tandem Accelerators and Related Techniques was held on June 8-9, 2000 at Mutsu, Aomori Prefecture, under the auspices of Marine Research Laboratory, Mutsu Establishment, the Japan Atomic Energy Research Institute. About 60 people participated in the meeting from 27 universities and organizations, many of which have a tandem accelerator or an electrostatic accelerator. The objectives of the meeting are to exchange information on tandem accelerates or electrostatic accelerators by making a presentation on related research and topics, and also to enhance mutual friendship of participants, resulting in the contribution to associated R and D. The meeting mainly consisted of presentations by participants and corresponding Q and A; the present situation on facilities of accelerator mass spectrometers (AMS), operations of and research on tandem accelerators or electrostatic accelerators, applications of AMS, related techniques and applications using accelerators, and so on. This report summarizes the contents of presentations made in the meeting. The 30 of the presented papers are indexed individually. (J.P.N.)

  16. Illumination technique for the relative calibration of the ASTRI SST-2M camera

    International Nuclear Information System (INIS)

    Rodeghiero, Gabriele; Catalano, Osvaldo; Segreto, Alberto; De Caprio, Vincenzo; Giro, Enrico; Lessio, Luigi; Conconi, Paolo; Canestrari, Rodolfo

    2014-01-01

    We present a new illumination technique for the camera relative gain calibration of the ASTRI SST-2M Cherenkov telescope. The camera illumination is achieved by means of an optical fiber that diffuses the light inside a protective PMMA window above the focal plane. We report the encouraging results of the development tests carried out on two PMMA window prototypes illuminated by a standard optical fiber. We checked also the reliability of the method by a series of ray tracing simulations for different scattering models and PMMA window shapes finding good agreement with experimental results

  17. Illumination technique for the relative calibration of the ASTRI SST-2M camera

    Energy Technology Data Exchange (ETDEWEB)

    Rodeghiero, Gabriele, E-mail: gabriele.rodeghiero@studenti.unipd.it [Department of Physics and Astronomy, University of Padova, Vicolo dell' Osservatorio 5, 35100 PD (Italy); Catalano, Osvaldo; Segreto, Alberto [INAF IASF Palermo, Via Ugo La Malfa 153, 90146 PA (Italy); De Caprio, Vincenzo [INAF OACN, Salita Moiariello, 16, 80131 Napoli, NA (Italy); Giro, Enrico; Lessio, Luigi [INAF OAPD, Vicolo dell' Osservatorio 5, 35100 PD (Italy); Conconi, Paolo; Canestrari, Rodolfo [INAF OAB, Via E. Bianchi 46, 23807 Merate, LC (Italy)

    2014-11-11

    We present a new illumination technique for the camera relative gain calibration of the ASTRI SST-2M Cherenkov telescope. The camera illumination is achieved by means of an optical fiber that diffuses the light inside a protective PMMA window above the focal plane. We report the encouraging results of the development tests carried out on two PMMA window prototypes illuminated by a standard optical fiber. We checked also the reliability of the method by a series of ray tracing simulations for different scattering models and PMMA window shapes finding good agreement with experimental results.

  18. Related Research and Arthroscopy: Increasing the Breadth of Arthroscopy and Arthroscopy Techniques.

    Science.gov (United States)

    Wetzler, Merrick J; Brand, Jefferson C; Rossi, Michael J; Lubowitz, James H

    2017-11-01

    An editorial goal is to increase the breadth of Arthroscopy and Arthroscopy Techniques. Our readers are more than arthroscopic surgeons and scientists. Rather, the health care providers and scientists who read our journals are, first and foremost, physicians, allied health practitioners, and academic intellectuals whose interests include improving individual and public health and welfare across a wide spectrum of scholarly topics. By reaching a broader audience, we hope to expand our contribution to arthroscopic and related surgery and continue to develop the potential of our subspecialty. Copyright © 2017 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  19. Comparison of various spring analogy related mesh deformation techniques in two-dimensional airfoil design optimization

    Science.gov (United States)

    Yang, Y.; Özgen, S.

    2017-06-01

    During the last few decades, CFD (Computational Fluid Dynamics) has developed greatly and has become a more reliable tool for the conceptual phase of aircraft design. This tool is generally combined with an optimization algorithm. In the optimization phase, the need for regenerating the computational mesh might become cumbersome, especially when the number of design parameters is high. For this reason, several mesh generation and deformation techniques have been developed in the past decades. One of the most widely used techniques is the Spring Analogy. There are numerous spring analogy related techniques reported in the literature: linear spring analogy, torsional spring analogy, semitorsional spring analogy, and ball vertex spring analogy. This paper gives the explanation of linear spring analogy method and angle inclusion in the spring analogy method. In the latter case, two di¨erent solution methods are proposed. The best feasible method will later be used for two-dimensional (2D) Airfoil Design Optimization with objective function being to minimize sectional drag for a required lift coe©cient at di¨erent speeds. Design variables used in the optimization include camber and thickness distribution of the airfoil. SU2 CFD is chosen as the §ow solver during the optimization procedure. The optimization is done by using Phoenix ModelCenter Optimization Tool.

  20. Endovascular management of pancreatitis-related pseudoaneurysms: A review of techniques.

    Directory of Open Access Journals (Sweden)

    Bartosz Zabicki

    Full Text Available To present the various techniques used in the management of pancreatitis-related pseudoaneurysms of visceral vessels.The retrospective clinical study was carried out at the Department of Diagnostic and Interventional Radiology at Poznan University of Medical Sciences from 2011 to 2016. The fifteen patients included in the study were diagnosed with pseudoaneurysms of visceral arteries, as a complication of chronic pancreatitis. The diagnosis was made using contrast-enhanced computed tomography, followed by angiography. On admission, all patients were symptomatic, with varying degrees of abdominal pain. One patient was haemodynamically unstable. Treatments with endovascular techniques were analysed, along with their efficacy and outcomes. Coil embolisation was performed in 5 patients. Stent graft was used in 1 patient. Liquid embolic agents were used in 7 cases, of which 5 patients were treated with thrombin injection and 2 with Squid. A combination of techniques was used in 2 patients.The most common artery affected by pseudoaneurysm formation was the splenic artery (7/15; 46.7%, and the size of the pseudoaneurysms ranged from 27 mm to 85 mm. Primary technical success was achieved in 14 out of 15 patients (93.3%. One patient required reintervention. Two patients required splenectomy after embolisation due to splenic ischemia. No recanalisation was present at the follow-up computed tomography performed after 1 to 3 weeks, and no mortality was observed within 30 days.Vascular complications of pancreatitis require accurate diagnosis and immediate treatment. Endovascular intervention is highly effective and is the preferred treatment option. The technique used is determined based on vascular anatomy and the patient's haemodynamic status.

  1. Nuclear and related techniques for improving productivity of indigenous animals in harsh environments

    International Nuclear Information System (INIS)

    1986-01-01

    The seminar provided a forum to review the various ways by which nuclear and related methods can be used to improve animal nutrition, reproduction and disease control under the different ecological conditions prevailing in Africa and the Middle East. The seminar was held concurrently with an FAO/IAEA Advisory Group Meeting. The purpose of this meeting was for invited scientists from various disciplines to evaluate those nuclear and related techniques currently used to quantify such functions as animal adaptation, digestion and utilization of poor quality feedstuffs, reproductive efficiency and resistance to disease and other forms of stress. This volume contains a selection of the papers presented during the seminar as well as the Recommendations of the Advisory Group Meeting. Separate abstracts were prepared for 15 papers of this volume

  2. A novel approach to TEM preparation with a (7-axis stage) triple-beam FIB-SEM system

    Science.gov (United States)

    Clarke, Jamil J.

    2015-10-01

    material, and better pin pointing of the area of interest while reducing overall processing time for the TEM sample preparation process and enhancing repeatability through ease of use via software controls. The development of these new technologies, incorporating a third Ar/Xe ion beam column in conjunction with the electron and gallium ion beam column, a 7-axis stage for enhanced sample orientation with tilt functions in two axes and automated swing control along with a host of additional functions which address the factors aforementioned such as electron and ion scan techniques and curtain effect removal by the use of hardware and software components that are key to reduce typical FIB related artifacts, all of which are called "ACE [Anti Curtaining Effect] Technologies" are explained. The overall developments of these technologies are to address a significant point that productivity, throughput and repeatability are comprised by synergy between the user, application, software and hardware within a FIB-SEM system. The latest Hitachi FIB-SEM platform offers these innovations for reliability, repeatability and high quality lamella preparation for Cs-corrected (S)TEMs.

  3. NPP Multi-Biome: TEM Calibration Data, 1992, R1

    Data.gov (United States)

    National Aeronautics and Space Administration — This data set contains one data file (.csv format) that is known as the Terrestrial Ecosystem Model (TEM) data set. The data provide pool sizes and fluxes of carbon...

  4. NPP Multi-Biome: TEM Calibration Data, 1992, R1

    Data.gov (United States)

    National Aeronautics and Space Administration — ABSTRACT: This data set contains one data file (.csv format) that is known as the Terrestrial Ecosystem Model (TEM) data set. The data provide pool sizes and fluxes...

  5. Conservation through payments for an ecosys- tem service?

    African Journals Online (AJOL)

    tem service? In his Spotlights ... functions” and “ecosystem services” are being ridiculed by the developments in ... high price as legal marketing would avoid various middlemen. ... Diagnostic participatif de la gestion des ressources naturelles.

  6. Preparation of carbon-free TEM microgrids by metal sputtering

    International Nuclear Information System (INIS)

    Janbroers, S.; Kruijff, T.R. de; Xu, Q.; Kooyman, P.J.; Zandbergen, H.W.

    2009-01-01

    A new method for preparing carbon-free, temperature-stable Transmission Electron Microscope (TEM) grids is presented. An 80% Au/20% Pd metal film is deposited onto a 'holey' microgrid carbon supported on standard mixed-mesh Au TEM grids. Subsequently, the carbon film is selectively removed using plasma cleaning. In this way, an all-metal TEM film is made containing the 'same' microgrid as the original carbon film. Although electron transparency of the foil is reduced significantly, the open areas for TEM inspection of material over these areas are maintained. The metal foil can be prepared with various thicknesses and ensures good electrical conductivity. The new Au/Pd grids are stable to at least 775 K under vacuum conditions.

  7. Preparation of carbon-free TEM microgrids by metal sputtering

    Energy Technology Data Exchange (ETDEWEB)

    Janbroers, S., E-mail: stephan.janbroers@albemarle.com [Albemarle Catalysts B.V., Nieuwendammerkade 1-3, 1030 BE, Amsterdam (Netherlands); Kavli Institute of Nanoscience, Delft University of Technology, Lorentzweg 1, 2628 CJ Delft (Netherlands); Kruijff, T.R. de; Xu, Q. [Kavli Institute of Nanoscience, Delft University of Technology, Lorentzweg 1, 2628 CJ Delft (Netherlands); Kooyman, P.J. [DelftChemTech, Delft University of Technology, Julianalaan 136, 2628 BL, Delft (Netherlands); Kavli Institute of Nanoscience, Delft University of Technology, Lorentzweg 1, 2628 CJ Delft (Netherlands); Zandbergen, H.W. [Kavli Institute of Nanoscience, Delft University of Technology, Lorentzweg 1, 2628 CJ Delft (Netherlands)

    2009-08-15

    A new method for preparing carbon-free, temperature-stable Transmission Electron Microscope (TEM) grids is presented. An 80% Au/20% Pd metal film is deposited onto a 'holey' microgrid carbon supported on standard mixed-mesh Au TEM grids. Subsequently, the carbon film is selectively removed using plasma cleaning. In this way, an all-metal TEM film is made containing the 'same' microgrid as the original carbon film. Although electron transparency of the foil is reduced significantly, the open areas for TEM inspection of material over these areas are maintained. The metal foil can be prepared with various thicknesses and ensures good electrical conductivity. The new Au/Pd grids are stable to at least 775 K under vacuum conditions.

  8. Preparation of carbon-free TEM microgrids by metal sputtering.

    Science.gov (United States)

    Janbroers, S; de Kruijff, T R; Xu, Q; Kooyman, P J; Zandbergen, H W

    2009-08-01

    A new method for preparing carbon-free, temperature-stable Transmission Electron Microscope (TEM) grids is presented. An 80% Au/20% Pd metal film is deposited onto a 'holey' microgrid carbon supported on standard mixed-mesh Au TEM grids. Subsequently, the carbon film is selectively removed using plasma cleaning. In this way, an all-metal TEM film is made containing the 'same' microgrid as the original carbon film. Although electron transparency of the foil is reduced significantly, the open areas for TEM inspection of material over these areas are maintained. The metal foil can be prepared with various thicknesses and ensures good electrical conductivity. The new Au/Pd grids are stable to at least 775K under vacuum conditions.

  9. Regulation of ETG turbulence by TEM driven zonal flows

    Science.gov (United States)

    Asahi, Yuuichi; Ishizawa, Akihiro; Watanabe, Tomohiko; Tsutsui, Hiroaki; Tsuji-Iio, Shunji

    2013-10-01

    Anomalous heat transport driven by electron temperature gradient (ETG) turbulence is investigated by means of gyrokinetic simulations. It is found that the ETG turbulence can be suppressed by zonal flows driven by trapped electron modes (TEMs). The TEMs appear in a statistically steady state of ETG turbulence and generate zonal flows, while its growth rate is much smaller than those of ETGs. The TEM-driven zonal flows with lower radial wave numbers are more strongly generated than those driven by ETG modes, because of the higher zonal flow response to a density source term. An ExB shearing rate of the TEM-driven zonal flows is strong enough to suppress the long-wavelength ETG modes which make the main contribution to the turbulent transport.

  10. Coordinated Isotopic and TEM Studies of Presolar Graphites from Murchison

    Science.gov (United States)

    Croat, T. K.; Stadermann, F. J.; Zinner, E.; Bernatowicz, T. J.

    2004-03-01

    TEM and NanoSIMS investigations of the same presolar Murchison KFC graphites revealed high Zr, Mo, and Ru content in refractory carbides within the graphites. Along with isotopically light carbon, these suggest a low-metallicity AGB source.

  11. Influence of porosity and relative humidity on consolidation of dolostone with calcium hydroxide nanoparticles: Effectiveness assessment with non-destructive techniques

    Energy Technology Data Exchange (ETDEWEB)

    Lopez-Arce, P., E-mail: plopezar@geo.ucm.es [Group of Applied Petrology to Heritage Conservation, Institute of Economic Geology (CSIC-UCM), Madrid 28040 (Spain); Gomez-Villalba, L.S. [Group of Applied Petrology to Heritage Conservation, Institute of Economic Geology (CSIC-UCM), Madrid 28040 (Spain); Pinho, L. [Center of Construction Studies, Engineering Faculty, Oporto University, Oporto 4200-465 (Portugal); Fernandez-Valle, M.E. [Research Assistance Center, Nuclear Magnetic Resonance (Pluridisciplinar Institute), Complutense University of Madrid (UCM), Madrid 28040 (Spain); Alvarez de Buergo, M.; Fort, R. [Group of Applied Petrology to Heritage Conservation, Institute of Economic Geology (CSIC-UCM), Madrid 28040 (Spain)

    2010-02-15

    Slaked lime (Ca(OH){sub 2}) nanoparticles were exposed at 33% and 75% relative humidity (RH) to consolidate dolostone samples used in historical buildings. Non-destructive techniques (NDT) were applied to determine the chemical, morphological, physical and hydric properties of the stone samples, before and after 20 days treatment. Morphological and mineralogical characterisation of the nanoparticles was performed. 75% RH favors the consolidation process studied under Environmental Scanning Electron Microscopy (ESEM-EDS), spectrophotometry, capillarity, water absorption under vacuum, ultrasound velocity, Nuclear Magnetic Resonance (imaging and relaxometry) and Optical Surface Roughness analyses. At 75% RH the nanoparticles fill the pores and inter-crystalline dolomite grain contacts but do not favor calcite re-crystallization as it occurs at 33% RH. The ESEM, XRD and TEM analyses under 75% RH reveal the fast transformation of portlandite (Ca(OH){sub 2}) into vaterite (CaCO{sub 3}), monohydrocalcite (CaCO{sub 3} . H{sub 2}O) and calcite (CaCO{sub 3}), and eventually the physical and hydric properties of the stones significantly improve. New insights are provided for the assessment of consolidation effectiveness of porous carbonate stones with calcium hydroxide nanoparticles under optimum RH conditions combining several NDT.

  12. Influence of porosity and relative humidity on consolidation of dolostone with calcium hydroxide nanoparticles: Effectiveness assessment with non-destructive techniques

    International Nuclear Information System (INIS)

    Lopez-Arce, P.; Gomez-Villalba, L.S.; Pinho, L.; Fernandez-Valle, M.E.; Alvarez de Buergo, M.; Fort, R.

    2010-01-01

    Slaked lime (Ca(OH) 2 ) nanoparticles were exposed at 33% and 75% relative humidity (RH) to consolidate dolostone samples used in historical buildings. Non-destructive techniques (NDT) were applied to determine the chemical, morphological, physical and hydric properties of the stone samples, before and after 20 days treatment. Morphological and mineralogical characterisation of the nanoparticles was performed. 75% RH favors the consolidation process studied under Environmental Scanning Electron Microscopy (ESEM-EDS), spectrophotometry, capillarity, water absorption under vacuum, ultrasound velocity, Nuclear Magnetic Resonance (imaging and relaxometry) and Optical Surface Roughness analyses. At 75% RH the nanoparticles fill the pores and inter-crystalline dolomite grain contacts but do not favor calcite re-crystallization as it occurs at 33% RH. The ESEM, XRD and TEM analyses under 75% RH reveal the fast transformation of portlandite (Ca(OH) 2 ) into vaterite (CaCO 3 ), monohydrocalcite (CaCO 3 . H 2 O) and calcite (CaCO 3 ), and eventually the physical and hydric properties of the stones significantly improve. New insights are provided for the assessment of consolidation effectiveness of porous carbonate stones with calcium hydroxide nanoparticles under optimum RH conditions combining several NDT.

  13. Work-related thumb disorders in South African physiotherapists treating musculoskeletal conditions using manual therapy techniques

    Directory of Open Access Journals (Sweden)

    Heather Jenkins

    2015-05-01

    Full Text Available Research question: What is the prevalence of and factors associated with work-related thumb problems (WRTP in South African physiotherapists treating musculoskeletal conditions using manual therapy techniques? Design: A cross-sectional, descriptive study design was used and data were collected using two Internet-based questionnaires. Participants: The sample size calculated for the study was 284 using 95% confidence levels and a 5% margin of error. There were 395 participants that were included in the study. Outcome measures: The variables measured included demographic, employment, educational and occupational factors. Results: The lifetime prevalence of WRTP in the physiotherapists was 65.3%. The manual techniques that were significantly associated with WRTP in the respondents who reported thumb problems were all grades of transverse glides applied to the spine as well as grade II–IV unilateral and central posterior-anterior pressures to the spine. The factors that remained significantly associated with WRTP in all 395 respondents after regression analysis were the cervical treatment of up to six patients a day and hyperextension > 30° of the non-dominant interphalangeal (IP joint of the thumb. Conclusion: This study confirms that a high percentage of physiotherapists using manual therapy techniques to treat musculoskeletal conditions are experiencing WRTP. Recommendations: The development of a valid and reliable WRTP screening tool is needed to aid in the identification of physiotherapists at risk and thus in the primary prevention of WRTP. A longitudinal study which follows newly qualified physiotherapists is recommended to investigate a possible cause-effect relationship and preventative strategies for WRTP in physiotherapists.

  14. TEM and ellipsometry studies of nanolaminate oxide films prepared using atomic layer deposition

    Energy Technology Data Exchange (ETDEWEB)

    Mitchell, D.R.G. [Materials and Engineering Science, ANSTO, PMB 1, Menai, NSW 2234 (Australia)]. E-mail: drm@ansto.gov.au; Attard, D.J. [Materials and Engineering Science, ANSTO, PMB 1, Menai, NSW 2234 (Australia); Finnie, K.S. [Materials and Engineering Science, ANSTO, PMB 1, Menai, NSW 2234 (Australia); Triani, G. [Materials and Engineering Science, ANSTO, PMB 1, Menai, NSW 2234 (Australia); Barbe, C.J. [Materials and Engineering Science, ANSTO, PMB 1, Menai, NSW 2234 (Australia); Depagne, C. [Materials and Engineering Science, ANSTO, PMB 1, Menai, NSW 2234 (Australia); Bartlett, J.R. [Materials and Engineering Science, ANSTO, PMB 1, Menai, NSW 2234 (Australia)

    2005-04-30

    Nanolaminate oxide layers consisting of TiO{sub 2} and Al{sub 2}O{sub 3} have been deposited on silicon using atomic layer deposition (ALD). Characterisation of these films has been achieved by use of a range of modern transmission electron microscopy (TEM)-based techniques, including plasmon loss imaging, energy filtered imaging and scanning TEM (STEM) X-ray line profiling. These have shown that the target thickness of the individual layers in the nanolaminate structures (20 nm) has been met with a high degree of accuracy, that the layers are extremely flat and parallel and that the interfaces between the layers are compositionally abrupt. Localised crystallisation within the stacks, and responses to electron beam irradiation point to the presence of a stress gradient within the layers. The performance of ellipsometry in characterising multilayer stacks has been benchmarked against the TEM measurements. Errors in determination of individual layer thicknesses were found to increase with growing stack size, as expected given the increasing number of interfaces incorporated in each model. The most sophisticated model gave maximum deviations of {+-}4 nm from the TEM determined values for the 5- and 10-layer stacks.

  15. A nonlinear filtering algorithm for denoising HR(S)TEM micrographs

    International Nuclear Information System (INIS)

    Du, Hongchu

    2015-01-01

    Noise reduction of micrographs is often an essential task in high resolution (scanning) transmission electron microscopy (HR(S)TEM) either for a higher visual quality or for a more accurate quantification. Since HR(S)TEM studies are often aimed at resolving periodic atomistic columns and their non-periodic deviation at defects, it is important to develop a noise reduction algorithm that can simultaneously handle both periodic and non-periodic features properly. In this work, a nonlinear filtering algorithm is developed based on widely used techniques of low-pass filter and Wiener filter, which can efficiently reduce noise without noticeable artifacts even in HR(S)TEM micrographs with contrast of variation of background and defects. The developed nonlinear filtering algorithm is particularly suitable for quantitative electron microscopy, and is also of great interest for beam sensitive samples, in situ analyses, and atomic resolution EFTEM. - Highlights: • A nonlinear filtering algorithm for denoising HR(S)TEM images is developed. • It can simultaneously handle both periodic and non-periodic features properly. • It is particularly suitable for quantitative electron microscopy. • It is of great interest for beam sensitive samples, in situ analyses, and atomic resolution EFTEM

  16. Determination of the initial oxidation behavior of Zircaloy-4 by in-situ TEM

    International Nuclear Information System (INIS)

    Harlow, Wayne; Ghassemi, Hessam; Taheri, Mitra L.

    2016-01-01

    The corrosion behavior of Zircaloy-4 (Zry-4), specifically by oxidation, is a problem of great importance as this material is critical for current nuclear reactor cladding. The early formation behavior and structure of the oxide layer during oxidation was studied using in-situ TEM techniques that allowed for Zry-4 to be monitored during corrosion. These environmental exposure experiments were coupled with precession electron diffraction to identify and quantify the phases present in the samples before and after the oxidation. Following short-term, high temperature oxidation, the dominant phase was revealed to be monoclinic ZrO 2 in a columnar structure. These samples oxidized in-situ contained structures that correlated well with bulk Zry-4 subjected to autoclave treatment, which were used for comparison and validation of this technique. By using in-situ TEM the effect of microstructure features, such as grain boundaries, on oxidation behavior of an alloy can be studied. The technique presented herein holds the potential to be applied any alloy system to study these effects. - Highlights: • In-situ TEM was used to oxidize samples of Zircaloy-4. • Similar behavior was found in the in-situ oxidized and autoclave-oxidized samples. • Precession diffraction was used to characterize oxide phase and texture.

  17. Application of SEM/EBSD and FEG-TEM/CBED to determine eutectic solidification mechanisms

    International Nuclear Information System (INIS)

    Nogita, K.; Dahle, A.K.; Drennan, J.

    2002-01-01

    Full text: This study shows the application of electron backscatter diffraction (EBSD) in SEM and convergent beam electron diffraction (CBED) in FEG-TEM to determine eutectic nucleation and growth in hypoeutectic Al-Si foundry alloys. Because the eutectic reaction is often the final stage of solidification it can be expected to have a significant impact on the formation of casting defects, particularly porosity. Previous EBSD work by Nogita and Dahle (2001), Dahle et al (2001), has shown that the eutectic nucleates on the primary phase in the unmodified alloy, and eutectic grains are nucleated in the intergranular liquid, instead of filling the dendrite envelopes, when Sr or Sb is added. However, the orientation relationship between silicon and aluminium in the eutectic has so far not been determined because of difficulties with sample preparation for EBSD and also detection limitations of Kikuchi refraction of silicon and aluminium, particularly in modified alloys with a refined eutectic. The combination of the EBSD technique in SEM and CBED in TEM analyses can provide crystallographic orientation relationships between primary aluminium dendrites, eutectic aluminium and silicon, which are important to explicitly define the solidification mode of the eutectic in hypoeutectic Al-Si alloys. These relationships are influenced, and altered, by the addition of certain elements. This paper also describes the sample preparation techniques for SEM and TEM for samples with different eutectic structures. The advantages the techniques are discussed. Copyright (2002) Australian Society for Electron Microscopy Inc

  18. Quantitative TEM study of the precipitation microstructure in aluminium alloy Al(MgSiCu) 6056 T6

    International Nuclear Information System (INIS)

    Delmas, F.; Casanove, M.J.; Lours, P.; Couret, A.; Coujou, A.

    2004-01-01

    The precipitate microstructure in the last-generation aluminium alloy 6056 T6 [AlMgSiCu] is investigated using three complementary techniques of transmission electron microscopy (TEM) with a special focus on the density and volume fraction of strengthening particles. High-resolution TEM allows the identification of the precipitates and the measurement of the precipitate sizes to be performed. Conventional TEM is used to evaluate the number of precipitates in the investigated area as well as their distribution in the matrix. In situ TEM straining, via the analysis of the dislocation slip traces, permits to determine precisely the thickness and the volume of the foil in the region where the precipitates are analysed. Taking into account the shape and the dimensions of precipitates with respect to the foil thickness, a novel methodology for measuring the volume density and the volume fraction of precipitates is proposed

  19. Evaluation of auditory perception development in neonates by event-related potential technique.

    Science.gov (United States)

    Zhang, Qinfen; Li, Hongxin; Zheng, Aibin; Dong, Xuan; Tu, Wenjuan

    2017-08-01

    To investigate auditory perception development in neonates and correlate it with days after birth, left and right hemisphere development and sex using event-related potential (ERP) technique. Sixty full-term neonates, consisting of 32 males and 28 females, aged 2-28days were included in this study. An auditory oddball paradigm was used to elicit ERPs. N2 wave latencies and areas were recorded at different days after birth, to study on relationship between auditory perception and age, and comparison of left and right hemispheres, and males and females. Average wave forms of ERPs in neonates started from relatively irregular flat-bottomed troughs to relatively regular steep-sided ripples. A good linear relationship between ERPs and days after birth in neonates was observed. As days after birth increased, N2 latencies gradually and significantly shortened, and N2 areas gradually and significantly increased (both Pbrain were significantly greater, and N2 latencies in the central part were significantly shorter in the left hemisphere compared with the right, indicative of left hemisphere dominance (both Pdevelopment. In the days following birth, the auditory perception ability of neonates gradually increases. This occurs predominantly in the left hemisphere, with auditory perception ability appearing to develop earlier in female neonates than in males. ERP can be used as an objective index used to evaluate auditory perception development in neonates. Copyright © 2017 The Japanese Society of Child Neurology. Published by Elsevier B.V. All rights reserved.

  20. Parameters of Dismantling Techniques Related to Costs for Decommissioning of Nuclear Facilities

    International Nuclear Information System (INIS)

    Jeong, Kwanseong; Moon, Jeikwon; Choi, Byungseon

    2012-01-01

    Reliable cost estimating is one of the most important elements of decommissioning operation. Reliable cost estimating is one of the most important elements of decommissioning planning. Alternative technologies may be evaluated and compared on their efficiency and effectiveness, and measured against a baseline cost as to the feasibility and benefit derived from the technology. This principle ensures that the cost consideration is economically sound and practical for funding. This paper provides a list with basic review of cutting and dismantling techniques, including some typical characteristics if available, as well as aspects of implementation, parameters of cutting and dismantling techniques in decommissioning costing. This paper gives an overview of the principles of the unit factor approach and its implementation in costing in relation to dismantling activities. In general, proper evaluation of decommissioning costs is important for following issues and relevant measures for achieving the listed aspects are: · Selection of a decommissioning strategy and activities: several decommissioning options should be evaluated: · Support to a cost-benefit analysis to ensure that the principle of optimization and reasonably practicable measures are applied: the extent of evaluated decommissioning options should cover all possible scenarios for dismantling activities; · Estimate of required financial resources for the selected strategy: the selected option should involve the dismantling activities in a structure and extent relevant to real procedure of dismantling activities; · Preparation of the project schedule, workforce requirements and phased funding needs: dismantling activities should be structured according to the tasks of the decommissioning schedule; · Definition of measures for proper management and maintenance of resources for safe and timely decommissioning: the time distribution and safety related parameters of dismantling activities should be known

  1. Development and applications of laser spectroscopic techniques related to combustion diagnostics

    International Nuclear Information System (INIS)

    Alden, Marcus

    2006-01-01

    Thanks to features as non-intrusiveness combined with high spatial and temporal resolution, various laser diagnostic techniques have during the last decades become of utmost importance for characterization of combustion related phenomena. In the following presentation some further development of the techniques will be highlighted aiming at a) surface temperatures using Thermographic Phosphors, TP, b) species specific, spatially and temporally resolved detection of species absorbing in the IR spectral region using polarization spectroscopy and Laser-induced fluorescence, and finally c) high speed visualization using a special designed laser system in combination with a framing camera. In terms of surface thermometry, Thermographic Phosphors have been used for many years for temperature measurements on solid surfaces. We have during the last years further developed and applied this technique for temperature measurements on burning surfaces and on materials going through phase shifts, e.g. pyrolysis and droplets. The basic principle behind this technique is to apply micron size particles to the surface of interest. By exciting the TP with a short pulse UV laser (ns), the phosphorescence will exhibit a behaviour where the spectral emission as well as the temporal decay are dependent on the temperature. It is thus possible to measure the temperature both in one and two dimensions. The presentation will include basic description of the technique as well as various applications, e.g in fire science, IC engines and gasturbines. Several of the species of interest for combustion/flow diagnostics exhibit a molecular structure which inhibits the use of conventional laser-induced fluorescence for spatially and spectrally resolved measurements. We have during the last years investigated the use of excitation and detection in the infrared region of the spectrum. Here, it is possible to detect both carbonmono/dioxide, water as well as species specific hydrocarbons. The techniques

  2. Survey on Ranging Sensors and Cooperative Techniques for Relative Positioning of Vehicles

    Directory of Open Access Journals (Sweden)

    Fabian de Ponte Müller

    2017-01-01

    Full Text Available Future driver assistance systems will rely on accurate, reliable and continuous knowledge on the position of other road participants, including pedestrians, bicycles and other vehicles. The usual approach to tackle this requirement is to use on-board ranging sensors inside the vehicle. Radar, laser scanners or vision-based systems are able to detect objects in their line-of-sight. In contrast to these non-cooperative ranging sensors, cooperative approaches follow a strategy in which other road participants actively support the estimation of the relative position. The limitations of on-board ranging sensors regarding their detection range and angle of view and the facility of blockage can be approached by using a cooperative approach based on vehicle-to-vehicle communication. The fusion of both, cooperative and non-cooperative strategies, seems to offer the largest benefits regarding accuracy, availability and robustness. This survey offers the reader a comprehensive review on different techniques for vehicle relative positioning. The reader will learn the important performance indicators when it comes to relative positioning of vehicles, the different technologies that are both commercially available and currently under research, their expected performance and their intrinsic limitations. Moreover, the latest research in the area of vision-based systems for vehicle detection, as well as the latest work on GNSS-based vehicle localization and vehicular communication for relative positioning of vehicles, are reviewed. The survey also includes the research work on the fusion of cooperative and non-cooperative approaches to increase the reliability and the availability.

  3. Novel sample preparation for operando TEM of catalysts.

    Science.gov (United States)

    Miller, Benjamin K; Barker, Trevor M; Crozier, Peter A

    2015-09-01

    A new TEM sample preparation method is developed to facilitate operando TEM of gas phase catalysis. A porous Pyrex-fiber pellet TEM sample was produced, allowing a comparatively large amount of catalyst to be loaded into a standard Gatan furnace-type tantalum heating holder. The increased amount of catalyst present inside the environmental TEM allows quantitative determination of the gas phase products of a catalytic reaction performed in-situ at elevated temperatures. The product gas concentration was monitored using both electron energy loss spectroscopy (EELS) and residual gas analysis (RGA). Imaging of catalyst particles dispersed over the pellet at atomic resolution is challenging, due to charging of the insulating glass fibers. To overcome this limitation, a metal grid is placed into the holder in addition to the pellet, allowing catalyst particles dispersed over the grid to be imaged, while particles in the pellet, which are assumed to experience identical conditions, contribute to the overall catalytic conversion inside the environmental TEM cell. The gas within the cell is determined to be well-mixed, making this assumption reasonable. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. Exploration of shallow subsurface resistivity structure using a portable TEM system: TEM-FAST prosystem; Kan`igata TEM ho sochi TEM-FAST prosystem ni yoru senbu hiteiko chosa

    Energy Technology Data Exchange (ETDEWEB)

    Miura, Y; Kumekawa, Y; Takasugi, S [GERD Geothermal Energy Research and Development Co. Ltd., Tokyo (Japan)

    1997-05-27

    Discussions were given on effectiveness of the TEM-FAST ProSystem which is a portable TEM system developed recently for use in exploration of shallow subsurface resistivity. The system consists of a loop type antenna, the TEM-FAST as the main equipment, and a host computer, the host computer controlling the entire system. The system acquires transient response data in secondary induced magnetic fields lasting 4 {mu} sec to 1 m sec. The number of data is 5490 stacks in one measurement, and the data acquisition time is about three minutes. Measurements were carried out by using the TEM-FAST in the vicinity of a well, whose results were compared with those of electric logging, and discussions were given on them. Although the electric logging results had no data available for depths shallower than 35 m, the measurement results from the TEM-FAST were found highly harmonious with those of the electric logging. In addition, there were transmission and telephone lines in locations about 10 m away from the well during the measurement, but extremely high data quality was discovered. 6 refs., 7 figs., 1 tab.

  5. A developed wedge fixtures assisted high precision TEM samples pre-thinning method: Towards the batch lamella preparation

    Directory of Open Access Journals (Sweden)

    Dandan Wang

    2017-04-01

    Full Text Available Ion milling, wedge cutting or polishing, and focused ion beam (FIB milling are widely-used techniques for the transmission electron microscope (TEM sample preparation. Especially, the FIB milling provides a site-specific analysis, deposition, and ablation of materials in the micrometer and nanometer scale. However, the cost of FIB tools has been always a significant concern. Since it is inevitable to use the FIB technique, the improvement of efficiency is a key point. Traditional TEM sample preparation with FIB was routinely implemented on a single sample each time. Aiming at cost efficiency, a new pre-thinning technique for batch sample preparation was developed in this paper. The present proposal combines the sample preparation techniques with multi-samples thinning, cross-section scanning electron microscopy (SEM, wedge cutting, FIB and other sample pre-thinning techniques. The new pre-thinning technique is to prepare an edge TEM sample on a grinding and polishing fixture with a slant surface. The thickness of the wedges sample can be measured to 1∼2 μm under optical microscope. Therefore, this fixture is superior to the traditional optical method of estimating the membrane thickness. Moreover, by utilizing a multi-sample holding fixture, more samples can be pre-thinned simultaneously, which significantly improved the productivity of TEM sample preparation.

  6. Performance of a field emission gun TEM/STEM

    International Nuclear Information System (INIS)

    Carpenter, R.W.; Bentley, J.

    1979-01-01

    First experimental results on a Phillips EM 400 TEM/STEM fitted with a field-emission electron gun and objective twin lens are given here. Operation of the FEG is reliable up to maximum design voltage (120 kV). Highest resolution achieved in TEM was 1.9 A fringe. A wide variety of diffraction modes were demonstrated, ranging from CBDP from a small area (approx. 10 A dia) in STEM mode to SAD with angular resolution of 8 μrad in TEM mode. The EDS sensitivity is very high. STEM imaging performance to the highest magnifications examined (200 kx) is good. Work is in progress to evaluate the limits of STEM performance

  7. SIMS and TEM study on oxide characteristics of Zircaloy

    International Nuclear Information System (INIS)

    Jung, Y. H.; Baek, J. H.; Kim, S. J.; Kim, K. H.; Choi, B. K.; Jung, Y. H.

    1998-01-01

    Long-term corrosion test, SIMS analysis, and TEM study were carried out to investigate the corrosion characteristics and corrosion mechanism of Zircaloy-4 in LiOH solution. The corrosion tests were performed in alkali solutions at 350 deg C for 500days. SIMS analysis was performed for the specimens prepared to have an equal oxide thickness to measure the cation content. TEM studies on the samples formed in various alkali solutions were also conducted. Based on the corrosion test, SIMS analysis, and TEM study, the cation is considered to control the corrosion in LiOH solution and its effect is dependent on the concentration of alkali and the oxide thickness. The slight acceleration of corrosion rate at a low concentration is thought to be caused by the cation incorporation into oxide while the significant acceleration at a high concentration is due to the transformation of oxide microstructure that would be induced by the cation incorporation

  8. Nanolithography and nanochemistry: probe-related patterning techniques and chemical modification for nanometer-sized devices

    NARCIS (Netherlands)

    Wouters, D.; Schubert, U.S.

    2004-01-01

    The size regime for devices produced by photolithographic techniques is limited. Therefore, other patterning techniques have been intensively studied to create smaller structures. Scanning-probe-based patterning techniques, such as dip-pen lithography, local force-induced patterning, and local-probe

  9. Environmental TEM in the in situ Toolbox

    DEFF Research Database (Denmark)

    Wagner, Jakob Birkedal

    on complementary experiments and characterization techniques. Normally, this is done in parallel with experiments separated in time and space [1] or mimicking a reaction by changing the conditions according to e.g. reactivity and conversion measured in dedicated catalyst set-ups [2]. Furthermore, dedicated...... the techniques to the microscope. A dedicated custom TEM specimen holder containing two optical fibres, five electrical contacts, a fixed miniaturized optical bench for light handling and a heating element has been designed. A system of pre-aligned mirrors and a MEMS heater are implemented in the holder...

  10. Drainage-related ultrasonography (DRUS): a novel technique for discriminating obstructive and nonobstructive hydroureters in children.

    Science.gov (United States)

    Kajbafzadeh, Abdol-Mohammad; Mehdizadeh, Mehrzad; Aryan, Zahra; Ebadi, Maryam; Esfahani, Shadi Abdar; Montaser-Kouhsari, Laleh; Elmi, Azadeh; Talab, Saman Shafaat; Sadeghi, Zhina

    2015-06-01

    Despite advances in urologic imaging, the paucity of an optimal technique that accurately clarifies obstructive and nonobstructive hydroureter exists. This study was conducted to introduce a novel and modified ultrasonographic technique, known as drainage-related ultrasonography (DRUS), discriminating obstructive and nonobstructive, nonrefluxing hydroureter. A total of 358 children (mean age, 3.7 years) with 418 nonrefluxing hydroureter were included. These children were composed of two groups of obstructive nonrefluxing (141 children with 157 dilated ureters) and nonobstructive, nonrefluxing (217 children with 261 hydroureter). The definite diagnosis regarding the subtype of hydroureter was derived from appropriate investigation. The maximum diameter of the dilated ureter, which was observed on ultrasonography, was recorded before and after 3 h of catheterization, as D1 and D2, respectively. To assess the D ratio, a formula was developed, that is, [(|D1 - D2|)/D1] × 100. Values were recorded and cutoff points were set to discriminate between subtypes. Obstructive versus nonobstructive subtypes of nonrefluxing hydroureter were clarified with 78.5 % sensitivity and 83.4 % specificity, by setting a cutoff point of 22 % for the D ratio. Regardless of the cutoff point assigned to the reduction in D (D2 compared with D1), DRUS revealed 93.9 % sensitivity, 80.6 % specificity, 63.2 % positive predictive value, and 97.4 % negative predictive value in discriminating upper from lower obstruction. DRUS affords favorable results in terms of differentiating between obstructive and nonobstructive, nonrefluxing hydroureter, as well as between upper and lower obstruction in obstructive cases. It has the potential to become an efficient imaging modality in the diagnostic algorithm of hydroureter.

  11. Impact produced by seoi-otoshi technique. Relation to years in practice and judo rank

    Directory of Open Access Journals (Sweden)

    Carlos Montero Carretero

    2014-02-01

    Full Text Available Judokas commonly train the seoi-otoshi technique (aka, drop-knee seoi-nage. A controversy exists about the convenience of its use by the younger judokas due to the risk of high loads produced by the impacts on their growing structures. The aim of the present paper was to measure the impacts against the tatami when executing the knee seoi-otoshi technique and its relationship with the years of practice and the degree or level (color of the belt. Thirty-three judokas from different years and degree volunteered to participate. Two force plates covered by standard tatami, registered the ground reaction forces while five consecutive repetitions were executed. We measured the mean and maximum peaks of force relative to their own body weight (BW. The results show peaks of more than 10 BW, which can be considered a potential risk of injury in the younger judokas, especially when repeated in time. In addition, a tendency to decrease the impact as the years of practice increase is observed (potential function; R2= 0.41, p<0.000 in the force peak, and the force in the expert group has been significantly lower than in the other groups (p<0.001. On the other hand, the degree (belt color shows a quadratic relationship (R2= 0.45, p<0.000 in the force peak. The lack of agreement between the years of practice and the degree shows that the promotion criteria does not appear to be a valid one from a preventive viewpoint, especially in the lower degrees which would correspond to younger practitioners whose locomotor structures are still not fully developed.

  12. A simple technique for treating age-related macular degeneration with external beam radiotherapy

    International Nuclear Information System (INIS)

    Roos, Daniel E.; Francis, J. Winston; Newnham, W. John

    1999-01-01

    Purpose: To develop a simple external beam photon radiotherapy technique to treat age-related macular degeneration without the need for simulation, planning computed tomography (CT) or computer dosimetry. Methods and Materials: The goal was to enable the treatment to be set up reliably on the treatment machine on Day 1 with the patient supine in a head cast without any prior planning. Using measurements of ocular globe topography from Karlsson et al. (Int J Radiat Oncol Biol Phys 1996; 33: 705-712), we chose a point 1.5 cm behind the anterior surface of the upper eyelid (ASUE) as the isocentre of a half-beam, blocked, 5.0 x 3.0-cm, angled lateral field to treat the involved eye. This would position the isocentre about 0.5 cm behind the posterior surface of the lens, and a little over 1 cm in front of the macula, according to Karlsson et al. The setup requires initial adjustment of the gantry from horizontal (to account for any asymmetry of position of the eyes), then angling 15 deg. posteriorly to avoid the contralateral eye. Finally, the couch is raised to position the isocentre 1.5 cm behind the ASUE. Results: To verify the applicability of the technique, we performed CT and computer dosimetry on the first 11 eyes so treated. Our CT measurements were in good agreement with Karlsson et al. The lens dose was < 5% and the macula was within the 95% isodose curve in each case (6-MV linac). Treatment setup time is approximately 10 min each day. The 11 patients were treated with 5 x 2.00 Gy (2 patients) or 5 x 3.00 Gy (9 patients), and subjective response on follow-up over 1 to 12 months (median 4 months) was comparable to previously reported results, with no significant acute side effects. Conclusion: Our technique is easy to set up and reliably treats the macula, with sparing of the lens and contralateral eye. It enables treatment to commence rapidly and cost-effectively without the need for simulation or CT computer planning

  13. Studies of osteoporosis in the Northern China, using isotope-related techniques

    International Nuclear Information System (INIS)

    Qin Linlin; Duan Yunbo; Ma Haibo; Zhang Wei; Ge Chonghua; Liu Zhonghou; Wang Shilin

    1996-01-01

    Osteoporosis is a systemic skeletal disease characterized by low bone mass and microarchitectural deterioration of bone tissue, with a consequent increase in bone fragility and susceptibility to fracture. Osteoporosis is an enormous public health problem, because it causes multiple fractures in the elderly people, and huge health care cost. The progressive aging of the world's population predicts a substantial increase in the global burden of osteoporosis, so further studying and preventing osteoporosis are often important problems. Since 1986 our department started large investigation of BMDat forearm using single photon absorptiometry (SPA) and in 1991-1993 was undertook Investigation of bone mineral density at the lumbar spine and proximal femur in normal Chinese population using Dual Energy X-ray Absorptiometry(DEXA). The results showed the BMD of all above sites is age-related, the age of peak BMD is different at the forearm, lumbar spine and hip, and the difference is related with sex. After the age of peak bone mass, BMD steadily declined with advancing age. In the Co-ordinated Research Programme on Comparative International Studies of Osteoporosis using Isotope Techniques. The first, we will further study age-, sex-related changes in bone mass among Chinese northern healthy residents in urban. Not only consider that chronic disease and medicine influence on osteoporosis, also consider the influence of life-style factors. The second, the trace elements of tooth and hair samples will be analysed by neutron activation analysis (NAA). It try to find the correlation of trace elements composition between tooth and hair samples. The possible difference in theses elements between osteoporotic patients and controls. (author)

  14. Developments in TEM Nanotomography of Calcium Silicate Hydrate

    KAUST Repository

    Taylor, Rae; Sakdinawat, Anne E.; Chae, Sejung R.; Wenk, Haz Rudolf; Levitz, Pierre E.; Sougrat, Rachid; Monteiro, Paulo José Meleragno

    2015-01-01

    This investigation was designed to explore the possibility of using transmission electron microscope (TEM) tomography on cement-based systems gain a greater understanding of their nanostructure and pore network. The preliminary results show a clearly a well-defined pore network at the nanoscale, with pore size approximately 1.7-2.4 nm in diameter and spaced around 5-8 nm apart. A comparison of small angle X-ray scattering data with 2-D TEM images analyzed with the Fourier slice theorem documents an excellent structural correlation. © 2015 The American Ceramic Society.

  15. Developments in TEM Nanotomography of Calcium Silicate Hydrate

    KAUST Repository

    Taylor, Rae

    2015-04-01

    This investigation was designed to explore the possibility of using transmission electron microscope (TEM) tomography on cement-based systems gain a greater understanding of their nanostructure and pore network. The preliminary results show a clearly a well-defined pore network at the nanoscale, with pore size approximately 1.7-2.4 nm in diameter and spaced around 5-8 nm apart. A comparison of small angle X-ray scattering data with 2-D TEM images analyzed with the Fourier slice theorem documents an excellent structural correlation. © 2015 The American Ceramic Society.

  16. Razvijmo sebe, druge in s tem svoj kraj

    Directory of Open Access Journals (Sweden)

    Dušana Findeisen

    1997-12-01

    Full Text Available Dušana Findeisen v tem prispevku obravnava vprašanje, kako spodbuditi ljudi k soodgovornosti za lasten razvoj in razvoj kraja. Preučuje tudi, kako naj prebivalci postanejo soodgovorni za zadostitev lastnih potreb in potreb njihovega kraja. V zvezi s tem se dotakne vloge izobraževalca odraslih - animatorja lokalnih projektov. Poudarja tudi pomen navezovanja novih odnosov in razmerij med lokalnimi skupnostmi in državo ter uvajanje “strukturalne politike”, kot jo imenuje avtorica, za sistemsko pomoč razvoju lokalnih projektov. Nazadnje pa obravnava vlogo lokalnih projektov z vidika razvoja kraja.

  17. Cosmic non-TEM radiation and synthetic feed array sensor system in ASIC mixed signal technology

    Science.gov (United States)

    Centureli, F.; Scotti, G.; Tommasino, P.; Trifiletti, A.; Romano, F.; Cimmino, R.; Saitto, A.

    2014-08-01

    The paper deals with the opportunity to introduce "Not strictly TEM waves" Synthetic detection Method (NTSM), consisting in a Three Axis Digital Beam Processing (3ADBP), to enhance the performances of radio telescope and sensor systems. Current Radio Telescopes generally use the classic 3D "TEM waves" approximation Detection Method, which consists in a linear tomography process (Single or Dual axis beam forming processing) neglecting the small z component. The Synthetic FEED ARRAY three axis Sensor SYSTEM is an innovative technique using a synthetic detection of the generic "NOT strictly TEM Waves radiation coming from the Cosmo, which processes longitudinal component of Angular Momentum too. Than the simultaneous extraction from radiation of both the linear and quadratic information component, may reduce the complexity to reconstruct the Early Universe in the different requested scales. This next order approximation detection of the observed cosmologic processes, may improve the efficacy of the statistical numerical model used to elaborate the same information acquired. The present work focuses on detection of such waves at carrier frequencies in the bands ranging from LF to MMW. The work shows in further detail the new generation of on line programmable and reconfigurable Mixed Signal ASIC technology that made possible the innovative Synthetic Sensor. Furthermore the paper shows the ability of such technique to increase the Radio Telescope Array Antenna performances.

  18. GISAXS modelling of helium-induced nano-bubble formation in tungsten and comparison with TEM

    Science.gov (United States)

    Thompson, Matt; Sakamoto, Ryuichi; Bernard, Elodie; Kirby, Nigel; Kluth, Patrick; Riley, Daniel; Corr, Cormac

    2016-05-01

    Grazing-incidence small angle x-ray scattering (GISAXS) is a powerful non-destructive technique for the measurement of nano-bubble formation in tungsten under helium plasma exposure. Here, we present a comparative study between transmission electron microscopy (TEM) and GISAXS measurements of nano-bubble formation in tungsten exposed to helium plasma in the Large Helical Device (LHD) fusion experiment. Both techniques are in excellent agreement, suggesting that nano-bubbles range from spheroidal to ellipsoidal, displaying exponential diameter distributions with mean diameters μ=0.68 ± 0.04 nm and μ=0.6 ± 0.1 nm measured by TEM and GISAXS respectively. Depth distributions were also computed, with calculated exponential depth distributions with mean depths of 8.4 ± 0.5 nm and 9.1 ± 0.4 nm for TEM and GISAXS. In GISAXS modelling, spheroidal particles were fitted with an aspect ratio ε=0.7 ± 0.1. The GISAXS model used is described in detail.

  19. 3D TEM reconstruction and segmentation process of laminar bio-nanocomposites

    International Nuclear Information System (INIS)

    Iturrondobeitia, M.; Okariz, A.; Fernandez-Martinez, R.; Jimbert, P.; Guraya, T.; Ibarretxe, J.

    2015-01-01

    The microstructure of laminar bio-nanocomposites (Poly (lactic acid)(PLA)/clay) depends on the amount of clay platelet opening after integration with the polymer matrix and determines the final properties of the material. Transmission electron microscopy (TEM) technique is the only one that can provide a direct observation of the layer dispersion and the degree of exfoliation. However, the orientation of the clay platelets, which affects the final properties, is practically immeasurable from a single 2D TEM image. This issue can be overcome using transmission electron tomography (ET), a technique that allows the complete 3D characterization of the structure, including the measurement of the orientation of clay platelets, their morphology and their 3D distribution. ET involves a 3D reconstruction of the study volume and a subsequent segmentation of the study object. Currently, accurate segmentation is performed manually, which is inefficient and tedious. The aim of this work is to propose an objective/automated segmentation methodology process of a 3D TEM tomography reconstruction. In this method the segmentation threshold is optimized by minimizing the variation of the dimensions of the segmented objects and matching the segmented V clay (%) and the actual one. The method is first validated using a fictitious set of objects, and then applied on a nanocomposite

  20. The analyzing stratum formation and sediment environment using TEM for finding sandstone type uranium deposits in Mahuangquan area

    International Nuclear Information System (INIS)

    Zhao Xigang; He Jianguo; Zhao Cuiping; Lou Hansheng

    2010-01-01

    Transient electromagnetic method (TEM) is used to detect deep geological information for insidious sandstone type uranium deposits in Mahuangquan area. TEM surveying data is processed to build the relation between resistance rate and different petrology, to ensure three large electronic strata, and to explain the space position of sediment center and alluvial fan. Combining with ore control factors of sandstone type uranium deposit, it can conclude that the slope area and the alluvial fan are the key areas for further exploration work. (authors)

  1. Theoretical analysis and modeling of Thickness-Expansion Mode (TEM) sensors for fluid characterization.

    Science.gov (United States)

    Elvira, Luis; Resa, Pablo; Castro, Pedro

    2013-03-01

    In this paper, the principles of Thickness-Expansion Mode (TEM) resonators for the characterization of fluids are described. From the measurement of the resonance parameters of a TEM piezoelectric transducer, the compressional acoustic impedance of gases and liquids can be determined. Since the propagation of mechanical waves into the fluid is not necessary, information in a wide range of frequencies can be obtained. Alternatively, these sensors can be driven in combination with other ultrasonic techniques to simultaneously determine the density, speed of sound and viscosity of samples. Some potential applications include the probe monitoring of processes and the characterization of fluids under harsh conditions. The main experimental criteria for the design and construction of high-resolution impedance meters (such as piezoelectric material, protective coating or thermal response) have been studied using equivalent electrical circuit modeling and finite element analysis. Copyright © 2012 Elsevier B.V. All rights reserved.

  2. TEM study of the ion beam induced damage during 14 kev P+ implantation in silicon

    International Nuclear Information System (INIS)

    Rubanov, S.; Tamanyan, G.; Hudson, F.; Jamieson, D.N.; McCallum, J.C.; Prawer, S.

    2005-01-01

    The proposed silicon-based quantum computer architecture comprises an array of phosphorus donor atoms (qubits) positioned with nanometre accuracy beneath the surface of a semiconductor host, using a single ion implantation technique. The average depth of the implanted ions (the projected range R p ), lateral range R p 1, and the distribution of ions about that depth can be approximated as two-dimensional Gaussian with standard deviation ΔR p and ΔR p 1 (lateral straggle). Using transmission electron microscopy (TEM) we studied ion beam induced damage after 14 keV P + implantation in Si. The TEM images allowed us to compare the depth of the amorphous cluster formation to R p , R p 1, ΔR p 1 calculated from SRIM and hence determine evidence for the limitation on the accuracy of the position of the implanted ions imposed by straggling. (author). 4 refs., 3 figs

  3. A short note on how to convert a conventional analytical TEM into an analytical Low Voltage TEM

    International Nuclear Information System (INIS)

    Stöger-Pollach, M.

    2014-01-01

    The present work is a short note on the performance of a conventional transmission electron microscope (TEM) being operated at very low beam energies (below 20 keV). We discuss the high tension stability and resolving power of this uncorrected TEM. We find out that the theoretical lens performance can nearly be achieved in practice. We also demonstrate that electron energy loss spectra can be recorded at these low beam energies with standard equipment. The signal-to-noise ratio is sufficiently good for further data treatment like multiple scattering deconvolution and Kramers–Kronig analysis. - Highlights: • TEM operation at very low beam energies (below 20 keV). • Testing of hardware performance at low beam energies. • EELS spectra recorded with 10 keV electrons

  4. Analysis of web-based online services for GPS relative and precise point positioning techniques

    Directory of Open Access Journals (Sweden)

    Taylan Ocalan

    Full Text Available Nowadays, Global Positioning System (GPS has been used effectively in several engineering applications for the survey purposes by multiple disciplines. Web-based online services developed by several organizations; which are user friendly, unlimited and most of them are free; have become a significant alternative against the high-cost scientific and commercial software on achievement of post processing and analyzing the GPS data. When centimeter (cm or decimeter (dm level accuracies are desired, that can be obtained easily regarding different quality engineering applications through these services. In this paper, a test study was conducted at ISKI-CORS network; Istanbul-Turkey in order to figure out the accuracy analysis of the most used web based online services around the world (namely OPUS, AUSPOS, SCOUT, CSRS-PPP, GAPS, APPS, magicGNSS. These services use relative and precise point positioning (PPP solution approaches. In this test study, the coordinates of eight stations were estimated by using of both online services and Bernese 5.0 scientific GPS processing software from 24-hour GPS data set and then the coordinate differences between the online services and Bernese processing software were computed. From the evaluations, it was seen that the results for each individual differences were less than 10 mm regarding relative online service, and less than 20 mm regarding precise point positioning service. The accuracy analysis was gathered from these coordinate differences and standard deviations of the obtained coordinates from different techniques and then online services were compared to each other. The results show that the position accuracies obtained by associated online services provide high accurate solutions that may be used in many engineering applications and geodetic analysis.

  5. Establishing Food Traceability System Using Nuclear and Related Techniques in Malaysia

    International Nuclear Information System (INIS)

    Zainon Othman; Nazaratul Ashifa Abdullah Salim; Salmah Moosa; Roslanzairi Mostapha

    2015-01-01

    Determination of food traceability is important in quality control and safety of food. The dramatic increase in the volume of global trade and complexity of supply chains has caused a number of issues concerning food authenticity and safety. Commodities that attract premium prices are subject to fraud such as adulteration and counterfeit. This poses serious health risks due to unknown origin of the counterfeit. In addition to safety concern, the capability to certify food origin is becoming significant economic importance. In several countries, the use of geographical indications allows producers to obtain market recognition and often a premium price. In addressing food safety issues in Malaysia, the Food Hygiene Regulations (2009) has provision for traceability but mechanism on how traceability can be achieved is not prescribed. Present mechanism is mainly paper-based system that passes information along with the commodity. However, such system is subject to failure either inadvertently or deliberately (fraud). Thus there is a need to establish a science-based traceability system to support the food safety surveillance program in Malaysia. This paper presents the concept and use of nuclear and related techniques involving isotopic and elemental fingerprinting in determining the geographical origin of various food products and its potential application for traceability of Malaysian agricultural produce. (author)

  6. Calibration of CR-39 for radon-related parameters using sealed cup technique

    International Nuclear Information System (INIS)

    Abo-Elmagd, M.; Daif, M. M.

    2010-01-01

    Effective radium content, mass and areal radon exhalation rates of soil and rock samples are important radon-related parameters and can be used as a better indicator of radon risk. A sealed cup fitted to a CR-39 detector and to the sample under measurement is an advantageous passive device for the measurement of these parameters. The main factors affecting the results are the detector calibration factor and the sample weight. The results of an active technique (Lucas cell) and the CR-39 detector have been found to be correlated resulting in a reliable detector calibration factor. The result illustrates the dependence of the CR-39 calibration factor with the sample weight which is difficult to use in practice, because each sample weight has its own calibration factor of CR-39. It is reported to demonstrate the advantage of a back diffusion correction. After correcting the results for back diffusion effects, one obtains an approximately constant calibration factor for the sample volumes up to one-third the total sealed cup volume. For this condition the calibration factor is equal to 0.237 track cm -2 per Bq m -3 d with about 1% uncertainty. (authors)

  7. An Investigation into the Relation between the Technique of Movement and Overload in Step Aerobics

    Directory of Open Access Journals (Sweden)

    Alicja Rutkowska-Kucharska

    2017-01-01

    Full Text Available The aim of this research was to determine the features of a step workout technique which may be related to motor system overloading in step aerobics. Subjects participating in the research were instructors (n=15 and students (n=15 without any prior experience in step aerobics. Kinematic and kinetic data was collected with the use of the BTS SMART system comprised of 6 calibrated video cameras and two Kistler force plates. The subjects’ task was to perform basic steps. The following variables were analyzed: vertical, anteroposterior, and mediolateral ground reaction forces; foot flexion and abduction and adduction angles; knee joint flexion angle; and trunk flexion angle in the sagittal plane. The angle of a foot adduction recorded for the instructors was significantly smaller than that of the students. The knee joint angle while stepping up was significantly higher for the instructors compared to that for the students. Our research confirmed that foot dorsal flexion and adduction performed while stepping up increased load on the ankle joint. Both small and large angles of knee flexion while stepping up and down resulted in knee joint injuries. A small trunk flexion angle in the entire cycle of step workout shut down dorsal muscles, which stopped suppressing the load put on the spine.

  8. The principle of electron microscopy; SEM and TEM

    International Nuclear Information System (INIS)

    Fauzi, S.H.

    1992-01-01

    The article reviews the principle of electron microscopy which is used in scanning electron microscope (SEM) and transmission electron microscope (TEM). These instruments are important for the examination and analysis of the microstructural properties of solid objects. Relevance physical concept lies behind the devices are given. The main components of each device are also discussed

  9. Scattering of a TEM wave from a time varying surface

    Science.gov (United States)

    Elcrat, Alan R.; Harder, T. Mark; Stonebraker, John T.

    1990-03-01

    A solution is given for reflection of a plane wave with TEM polarization from a planar surface with time varying properties. These properties are given in terms of the currents on the surface. The solution is obtained by numerically solving a system of differential-delay equations in the time domain.

  10. TEM studies of P+ implanted and subsequently laser annealed Si

    International Nuclear Information System (INIS)

    Sadana, D.K.; Wilson, M.C.; Booker, G.R.; Washburn, J.

    1979-05-01

    The present investigation is concerned with laser annealing of P + implanted Si. The aim of the work was to study the crystallization behavior of damage structure occurring due to high dose rate implantation using transmission electron microscopy (TEM) as the method of examination

  11. TEM-turbulence in stellarators and its optimization

    Science.gov (United States)

    Proll, Josefine H. E.; Helander, Per; Lazerson, Samuel; Mynick, Harry; Xanthopoulos, Pavlos

    2014-10-01

    Quasi-isodynamic stellarators, which are especially optimized for neoclassical transport, have been shown to be resilient towards trapped-electrons modes (TEMs) in large regions of parameter space. In these configurations, all particles have average ``good curvature.'' It was shown analytically that, thanks to this property, particles that bounce faster than the mode in question draw energy from it near marginal stability, so that the ordinary density-gradient-driven TEM has to be stable in the electrostatic and collisionless limit.This has been confirmed in linear flux-tube simulations that were performed with the GENE code. Several magnetic field configurations were compared and it was found that the growth rates of the TEMs drop with increasing degree of quasi-isodynamicity. These findings can be used to optimize stellarators with respect to TEM turbulence by reducing the fraction of trapped particles with bounce averaged ``bad curvature.'' An appropriate proxy function has therefore been designed to be implemented in STELLOPT, a stellarator optimization tool that can now be used to further explore the configuration space of neoclassically optimized stellarators with the aim to extract designs with improved turbulent transport. This work was facilitated by the Max-Planck/Princeton Center for Plasma Physics.

  12. Nuclear and related techniques in control and epidemiology of haemoparasitic infections

    International Nuclear Information System (INIS)

    Duzgun, A.

    2004-01-01

    at least some production against challenge with parasite isolated from different areas. A general review of the studies carried out to diagnose and control of haemoparasitic infections with the aid of nuclear and related techniques is presented and discussed

  13. Nuclear and related techniques in control and epidemiology of haemoparasitic infections

    International Nuclear Information System (INIS)

    Duzgun, A.

    2004-01-01

    some production against challenge with parasite isolated from different areas. A general review of the studies carried out to diagnose and control of haemoparasitic infections with the aid of nuclear and related techniques is presented and discussed. (author)

  14. Crop improvement for salinity and drought tolerance using nuclear and related techniques (abstract)

    International Nuclear Information System (INIS)

    Serraj, R.; Lagoda, P.J.

    2005-01-01

    complex interactions among the traits involved in tolerance to both drought and salinity, pyramiding using marker-assisted breeding, induced mutation and other biotechnologies, combined with a multidisciplinary approach and the participation of farmers, is likely to provide the best strategy to accelerate the progress towards the development of adapted tolerant crop germplasm. The joint FAO/IAEA division is investing considerable effort in evaluating opportunities for using nuclear and related technologies to improve tolerance to abiotic stresses such as drought and salinity. The division has a long-standing experience in developing and coordinating collaborative research programs (CRP) on abiotic stresses, involving NARs in developing countries, international IARCs and expert scientists. Similarly, several technical cooperation projects (TCP) were carried out on crop improvement for tolerance to drought and salinity, at national, regional and interregional levels. The Soil and Biotechnology laboratories at Seibersdorf also have the experience and facilities for developing, testing and applying new isotope and nuclear-related techniques for the improvement of crop productivity and stress tolerance. An important project is currently being implemented by the joint FAO/IAEA division for the identification and development of crop germplasm with superior resource use efficiency and nutritional value and adapted to harsh environments. Two CRPs have been recently launched under this project dealing respectively with (i) the identification and pyramiding of mutated genes, and novel approaches for improving crop tolerance to salinity and drought, and (II) the selection for greater agronomic water-use efficiency in wheat and rice using carbon isotope discrimination under drought and saline environments. This paper will review the recent progress made at the joint FAO/IAEA division in deciphering the complexity of drought and salinity problems and developing drought and salt

  15. Studies of osteoporosis within the Debrecen regional osteoporosis program (drop) in Hungary using isotope related techniques

    International Nuclear Information System (INIS)

    Balogh, A.; Jozsa, Z.; Balogh, Z.; Kiss, A.Z.; Bettembuk, P.

    1996-01-01

    Estimates of the annual incidence of various osteoporotic fractures in Hungary only recently became available. Further prospective data are needed in order to get an estimate on the public health impact of osteoporosis. It has been postulated that beyond genetic factors, environmental effects play important roles in determining the peak bone mass. Many of the influential environmental factors and also the normal course of the development of peak bone mass need further investigation in our region, also to explore suspected interregional differences in bone health. This study will take place in a centre as participant of a multicentre international population study and aims to draw a random sample of the minimum of 105 persons of both sexes from the urban population (15 to 50) of Debrecen, a town of 220 thousand inhabitants in the Eastern region of Hungary and measure bone density of the spine, hip and total body using isotope related techniques. Further goal is to review major lifestyle variables, such as nutrition and exercise. Laboratory markers of bone metabolism will be assayed and bone samples obtained from victims of accidents to analyze bone quality and elemental composition. Alternative bone sites, such as teeth and oral alveolar bone will be also considered sources of bone samples for comparison to other bone regions. The duration of the study will be 4 years and the study subjects will be followed by repeated measurements and clinical assessment. The data will be collected and analyzed according to a common protocol supported by the IAEA. This makes possible comparing data from the participating countries. Experiences of previous work in this Institute on similar subject is also reviewed briefly. (author)

  16. Breast Cancer-Related Arm Lymphedema: Incidence Rates, Diagnostic Techniques, Optimal Management and Risk Reduction Strategies

    Energy Technology Data Exchange (ETDEWEB)

    Shah, Chirag [Department of Radiation Oncology, William Beaumont Hospital, Royal Oak, MI (United States); Vicini, Frank A., E-mail: fvicini@beaumont.edu [Department of Radiation Oncology, William Beaumont Hospital, Royal Oak, MI (United States)

    2011-11-15

    As more women survive breast cancer, long-term toxicities affecting their quality of life, such as lymphedema (LE) of the arm, gain importance. Although numerous studies have attempted to determine incidence rates, identify optimal diagnostic tests, enumerate efficacious treatment strategies and outline risk reduction guidelines for breast cancer-related lymphedema (BCRL), few groups have consistently agreed on any of these issues. As a result, standardized recommendations are still lacking. This review will summarize the latest data addressing all of these concerns in order to provide patients and health care providers with optimal, contemporary recommendations. Published incidence rates for BCRL vary substantially with a range of 2-65% based on surgical technique, axillary sampling method, radiation therapy fields treated, and the use of chemotherapy. Newer clinical assessment tools can potentially identify BCRL in patients with subclinical disease with prospective data suggesting that early diagnosis and management with noninvasive therapy can lead to excellent outcomes. Multiple therapies exist with treatments defined by the severity of BCRL present. Currently, the standard of care for BCRL in patients with significant LE is complex decongestive physiotherapy (CDP). Contemporary data also suggest that a multidisciplinary approach to the management of BCRL should begin prior to definitive treatment for breast cancer employing patient-specific surgical, radiation therapy, and chemotherapy paradigms that limit risks. Further, prospective clinical assessments before and after treatment should be employed to diagnose subclinical disease. In those patients who require aggressive locoregional management, prophylactic therapies and the use of CDP can help reduce the long-term sequelae of BCRL.

  17. Breast Cancer-Related Arm Lymphedema: Incidence Rates, Diagnostic Techniques, Optimal Management and Risk Reduction Strategies

    International Nuclear Information System (INIS)

    Shah, Chirag; Vicini, Frank A.

    2011-01-01

    As more women survive breast cancer, long-term toxicities affecting their quality of life, such as lymphedema (LE) of the arm, gain importance. Although numerous studies have attempted to determine incidence rates, identify optimal diagnostic tests, enumerate efficacious treatment strategies and outline risk reduction guidelines for breast cancer–related lymphedema (BCRL), few groups have consistently agreed on any of these issues. As a result, standardized recommendations are still lacking. This review will summarize the latest data addressing all of these concerns in order to provide patients and health care providers with optimal, contemporary recommendations. Published incidence rates for BCRL vary substantially with a range of 2–65% based on surgical technique, axillary sampling method, radiation therapy fields treated, and the use of chemotherapy. Newer clinical assessment tools can potentially identify BCRL in patients with subclinical disease with prospective data suggesting that early diagnosis and management with noninvasive therapy can lead to excellent outcomes. Multiple therapies exist with treatments defined by the severity of BCRL present. Currently, the standard of care for BCRL in patients with significant LE is complex decongestive physiotherapy (CDP). Contemporary data also suggest that a multidisciplinary approach to the management of BCRL should begin prior to definitive treatment for breast cancer employing patient-specific surgical, radiation therapy, and chemotherapy paradigms that limit risks. Further, prospective clinical assessments before and after treatment should be employed to diagnose subclinical disease. In those patients who require aggressive locoregional management, prophylactic therapies and the use of CDP can help reduce the long-term sequelae of BCRL.

  18. Towards in-situ tem analysis of PLD Pb(Zr,Ti)O3 thin film membranes

    NARCIS (Netherlands)

    Sardan Sukas, Ö.; Berenschot, Johan W.; de Boer, Meint J.; Nguyen, Duc Minh; van Zalk, M.; Abelmann, Leon

    2011-01-01

    In this paper, a novel technique for fabricating Transmission Electron Microscopy (TEM) chips for investigating structural and piezoelectric properties of Pulse Laser Deposited (PLD) Lead Zirconium Titanate (PZT) thin films is presented. The method involves silicon-on-insulator (SOI) wafer

  19. TEMs but not DKK1 could serve as complementary biomarkers for AFP in diagnosing AFP-negative hepatocellular carcinoma.

    Science.gov (United States)

    Mao, Liping; Wang, Yueguo; Wang, Delin; Han, Gang; Fu, Shouzhong; Wang, Jianxin

    2017-01-01

    Hepatitis B virus (HBV)-related hepatocellular carcinoma (HCC) is prevalent worldwide. Despite its limitations, serum alpha-fetoprotein (AFP) remains the most widely-used biomarker for the diagnosis of HCC. This study aimed to assess whether measurement of peripheral plasma Dickkopf-1 (DKK1) and Tie2-expressing monocytes (TEMs) could overcome the limitations of AFP and improve the diagnostic accuracy of HCC. Plasma DKK1 level and the percentage of TEMs in peripheral CD14+CD16+ monocytes from HCC patients (n = 82), HBV-related liver cirrhosis (LC) patients (n = 29), chronic hepatitis B (CHB) infected patients (n = 28) and healthy volunteers (n = 31) were analyzed by ELISA and flow cytometry. Receiver operating characteristic (ROC) curves were used to analyze a single biomarker, or a combination of two or three biomarkers. Univariate and multivariate analyses were performed to assess the significance of each marker in prediction of HCC and AFP-negative HCC from LC patients. The percentage of TEMs in peripheral CD14+CD16+ monocytes and plasma level of DKK1 in HCC group were significantly higher than those in LC, CHB and healthy control groups (all P-values TEMs alone was also significantly higher in AFP-negative HCC group than that in LC, CHB and healthy control groups (all P-values TEMs. There was no significant difference in AUC of DKK1, TEMs and AFP in HCC diagnosis between the four groups (all P>0.05). A combination of DKK1, TEMs and AFP measurements increased the AUC for HCC diagnosis as compared with either marker alone (0.833; 95%CI 0.768-0.886). The AUC for TEMs was 0.692 (95% CI 0.564-0.819) in differentiating AFP-negative HCC from LC, with a sensitivity of 80.0% and a specificity of 65.52%. Only TEMs prevailed as a significant predictor for AFP-negative HCC differentiating from LC patients in univariate and multivariate analyses (P = 0.016, P = 0.023). TEMs and DKK1 may prove to be potential complementary biomarkers for AFP in the diagnosis of HCC. TEMs

  20. Post Irradiation TEM Investigation of ZrN Coated U(Mo) Particles Prepared with FIB

    Energy Technology Data Exchange (ETDEWEB)

    Van Renterghem, W.; Leenaers, A.; Van den Berghe, S.; Miller, B. D.; Gan, J.; Madden, J. W.; Keiser, D. D.; Palancher, H.; Hofman, G. L.; Breitkreuz, H.

    2015-10-01

    In the framework of the Selenium project, two dispersion fuel plates were fabricated with Si and ZrN coated fuel particles and irradiated in the Br2 reactor of SCK•CEN to high burn-up. The first analysis of the irradiated plate proved the reduced swelling of the fuel plate and interaction layer growth up to 70% burn-up. The question was raised how the structure of the interaction layer had been affected by the irradiation and how the structure of the fuel particles had evolved. Hereto, samples from the ZrN coated UMo particles were prepared for transmission electron microscopy (TEM) using focused ion beam milling (FIB) at INL. The FIB technique allowed to precisely select the area of the interaction layer and/or fuel to produce a sample that is TEM transparent over an area of 20 by 20 µm. In this contribution, the first TEM results will be presented from the 66% burn-up sample.

  1. "Rinse and trickle": a protocol for TEM preparation and investigation of inorganic fibers from biological material.

    Science.gov (United States)

    Vigliaturo, Ruggero; Capella, Silvana; Rinaudo, Caterina; Belluso, Elena

    2016-07-01

    The purpose of this work is to define a sample preparation protocol that allows inorganic fibers and particulate matter extracted from different biological samples to be characterized morphologically, crystallographically and chemically by transmission electron microscopy-energy dispersive spectroscopy (TEM-EDS). The method does not damage or create artifacts through chemical attacks of the target material. A fairly rapid specimen preparation is applied with the aim of performing as few steps as possible to transfer the withdrawn inorganic matter onto the TEM grid. The biological sample is previously digested chemically by NaClO. The salt is then removed through a series of centrifugation and rinse cycles in deionized water, thus drastically reducing the digestive power of the NaClO and concentrating the fibers for TEM analysis. The concept of equivalent hydrodynamic diameter is introduced to calculate the settling velocity during the centrifugation cycles. This technique is applicable to lung tissues and can be extended to a wide range of organic materials. The procedure does not appear to cause morphological damage to the fibers or modify their chemistry or degree of crystallinity. The extrapolated data can be used in interdisciplinary studies to understand the pathological effects caused by inorganic materials.

  2. Studying the interface between cyanobacteria and biotite mineral surfaces using FIB and TEM

    International Nuclear Information System (INIS)

    Ward, M B; Brown, A P

    2014-01-01

    Recent analysis of the bioweathering of minerals has highlighted the challenges for investigating the interface between fungi or bacteria and the surface of the mineral that they live on. Transmission electron microscopy (TEM) with its ability to gather imaging information and collect elemental data at high spatial resolution is the ideal technique to analyse such interfaces. Further to this, a dual beam scanning electron and focused ion beam (FIB) microscope is an ideal instrument to prepare specimens for TEM because of its ability to simultaneously cut through hard and soft materials from specific sites of interest. There are however precautions that must be taken when analysing such mineral systems. The electron beam sensitive nature of most sheet silicate minerals means that consideration has to be made as to whether the structure and/or chemistry of the material is being altered during (S)TEM analysis. Here, results from a study of cyanobacteria grown on the surface of biotite are discussed. Particular reference is given to the methods used to determine an electron beam intensity threshold, below which STEM-EDX analysis could be performed without detrimental alteration to the mineral

  3. Novel Transrotational Solid State Order Discovered by TEM in Crystallizing Amorphous Films

    Science.gov (United States)

    Kolosov, Vladimir

    Exotic thin crystals with unexpected transrotational microstructures have been discovered by transmission electron microscopy (TEM) for crystal growth in thin (10-100 nm) amorphous films of different chemical nature (oxides, chalcogenides, metals and alloys) prepared by various methods. Primarily we use our TEM bend contour technique. The unusual phenomenon can be traced in situ in TEM column: dislocation independent regular internal bending of crystal lattice planes in a growing crystal. Such transrotation (unit cell trans lation is complicated by small rotationrealized round an axis lying in the film plane) can result in strong regular lattice orientation gradients (up to 300 degrees per micrometer) of different geometries: cylindrical, ellipsoidal, toroidal, saddle, etc. Transrotation is increasing as the film gets thinner. Transrotational crystal resembles ideal single crystal enclosed in a curved space. Transrotational micro crystals have been eventually recognized by other authors in some vital thin film materials, i.e. PCMs for memory, silicides, SrTiO3. Atomic model and possible mechanisms of the phenomenon are discussed. New transrotational nanocrystalline model of amorphous state is also proposed Support of RF Ministry of Education and Science is acknowledged.

  4. Solid Phase Microextraction and Related Techniques for Drugs in Biological Samples

    OpenAIRE

    Moein, Mohammad Mahdi; Said, Rana; Bassyouni, Fatma; Abdel-Rehim, Mohamed

    2014-01-01

    In drug discovery and development, the quantification of drugs in biological samples is an important task for the determination of the physiological performance of the investigated drugs. After sampling, the next step in the analytical process is sample preparation. Because of the low concentration levels of drug in plasma and the variety of the metabolites, the selected extraction technique should be virtually exhaustive. Recent developments of sample handling techniques are directed, from o...

  5. Relative mass resolution technique for optimum design of a gamma nondestructive assay system

    International Nuclear Information System (INIS)

    Koh, Duck Joon

    1995-02-01

    applications, a very simple and accurate Monte Carlo code is required to calculate average escape probability from a radwaste drum and average detection probability of gamma rays in a detector. Some concepts such as convexity theorem and relative mass resolution(RMR) which can determine the optimized detection position for the rad-waste drum are useful. The optimized detection point means a point which makes the summation of spatial uncertainty and statistical uncertainty of the measurement a minimum. At this detection point, we can achieve the best detection results with the minimized uncertainty which have been compared with the experimental results. The major applications are focused on the concentrated liquid waste drum, the spent resin waste drum, and the spent filter waste drum. The gamma sources in the sample drum were Co-60, Cs-137 and Pu-239, respectively. In a one-detector system, the minimum RMR lies between 70 cm and 90 cm apart from sample drum. The RMR of a two-detector system is superior to that of a one-detector system. The results of this study indicate that the Monte Carlo simulation and RMR technique used in generation of response functions of photons and calculation of the optimal detection position should be useful for the optimal design of NDA systems

  6. Bayesian resolution of TEM, CSEM and MT soundings: a comparative study

    Science.gov (United States)

    Blatter, D. B.; Ray, A.; Key, K.

    2017-12-01

    We examine the resolution of three electromagnetic exploration methods commonly used to map the electrical conductivity of the shallow crust - the magnetotelluric (MT) method, the controlled-source electromagnetic (CSEM) method and the transient electromagnetic (TEM) method. TEM and CSEM utilize an artificial source of EM energy, while MT makes use of natural variations in the Earth's electromagnetic field. For a given geological setting and acquisition parameters, each of these methods will have a different resolution due to differences in the source field polarization and the frequency range of the measurements. For example, the MT and TEM methods primarily rely on induced horizontal currents and are most sensitive to conductive layers while the CSEM method generates vertical loops of current and is more sensitive to resistive features. Our study seeks to provide a robust resolution comparison that can help inform exploration geophysicists about which technique is best suited for a particular target. While it is possible to understand and describe a difference in resolution qualitatively, it remains challenging to fully describe it quantitatively using optimization based approaches. Part of the difficulty here stems from the standard electromagnetic inversion toolkit, which makes heavy use of regularization (often in the form of smoothing) to constrain the non-uniqueness inherent in the inverse problem. This regularization makes it difficult to accurately estimate the uncertainty in estimated model parameters - and therefore obscures their true resolution. To overcome this difficulty, we compare the resolution of CSEM, airborne TEM, and MT data quantitatively using a Bayesian trans-dimensional Markov chain Monte Carlo (McMC) inversion scheme. Noisy synthetic data for this study are computed from various representative 1D test models: a conductive anomaly under a conductive/resistive overburden; and a resistive anomaly under a conductive/resistive overburden. In

  7. Enhancements and Health-Related Studies of Neutron Activation Analysis Technique

    International Nuclear Information System (INIS)

    Soliman, M.A.M.

    2012-01-01

    The work presented in this thesis covers two major points. One algorithm concerns with establishment of an accurate standardization method with multi-elemental capabilities and low workload suitable for NAA standardization at ETRR-2. The second one deals with constructing and developing an effective nondestructive technique for analysis of liquid samples based on NAA using (very) short-lived radionuclides. To achieve the first goal, attention has been directed toward implementation of the k 0 -method for calculation of the elements concentrations in the samples. The k 0 -method of NAA standardization has a considerable success as a method for accurate multi-elemental analysis with comparable low workload. The k 0 - method is based on the fact that the unknown sample is irradiated with only one standard element as comparator. To access the implementation of this method at ETRR-2, careful and complete characterization of the neutron flux parameters in the irradiation positions as well as the efficiency calibration of the γ-ray spectrometer must be carried out. The required neutron flux parameters are: the ratio of the thermal to epithermal neutron fluxes (f) and the deviation factor (α) of the epithermal neutron flux from the ideal 1/E law. The work presented in Chapter 4 shows the efficiency calibration curve of the γ ray spectrometer system which was obtained using standard radioactive point sources. Moreover, the f and α parameters were determined in some selected irradiation sites using sets of Zr-Au as neutron flux monitors. Due to different locations relative to the reactor core, the available neutron fluxes in the selected irradiation positions differ substantially, so that different irradiation demands can be satisfied. The reference materials coal NIST 1632c and IAEA-Soil 7 were analyzed for data validation and good agreement between the experimental values and the certified values was obtained. The obtained results have revealed that the k 0 -NAA

  8. In situ TEM observation of solid-gas reactions

    International Nuclear Information System (INIS)

    Kishita, K; Kamino, T; Watabe, A; Kuroda, K; Saka, H

    2008-01-01

    Under a gaseous atmosphere at high temperatures, almost all the materials (metal, catalysts, etc.) change their structures and properties. For the research and development of materials, it is of vital importance to clarify mechanisms of solid-gas and liquid-gas reactions. Recently an in situ TEM system combined with an environmental holder, which has a gas injection nozzle close to a specimen-heating element, has been developed. The gas injection nozzle permits gas to flow around the specimens sitting on the heating element made of a fine W filament. The newly developed in situ TEM has a differential pumping system; therefore, the pressure in the specimen chamber is maintained in the range of higher than 1 Pa, while the pressure in the electron gun chamber can be kept in the range of 10 -5 Pa. This system was applied to in situ observation of chemical reactions of metals with gases: Observation of oxidation and reduction under a gas pressure ranging from 10 -5 Pa to 1 Pa at high temperatures (room temperature to ∼1473 K) were successfully carried out on pure metal and rare metal catalysts at near-atomic resolution. This in situ environmental TEM system is promising for clarifying mechanisms of many solid-gas and liquid-gas reactions that take place at high temperatures under a gas atmosphere.

  9. TOPICAL REVIEW: Present status and future prospects of spherical aberration corrected TEM/STEM for study of nanomaterials

    Directory of Open Access Journals (Sweden)

    Nobuo Tanaka

    2008-01-01

    Full Text Available The present status of Cs-corrected TEM/STEM is described from the viewpoint of the observation of nanomaterials. Characteristic features in TEM and STEM are explained using the experimental data obtained by our group and other research groups. Cs correction up to the 3rd-order aberration of an objective lens has already been established and research interest is focused on correcting the 5th-order spherical aberration and the chromatic aberration in combination with the development of a monochromator below an electron gun for smaller point-to-point resolution in optics. Another fundamental area of interest is the limitation of TEM and STEM resolution from the viewpoint of the scattering of electrons in crystals. The minimum size of the exit-wave function below samples undergoing TEM imaging is determined from the calculation of scattering around related atomic columns in the crystals. STEM does not have this limitation because the resolution is, in principle, determined by the probe size. One of the future prospects of Cs-corrected TEM/STEM is the possibility of extending the space around the sample holder by correcting the chromatic and spherical aberrations. This wider space will contribute to the ease of performing in situ experiments and various combinations of TEM and other analysis methods. High-resolution, in situ dynamic and 3D observations/analysis are the most important keywords in the next decade of high-resolution electron microscopy.

  10. In-Situ TEM-STM Observations of SWCNT Ropes/Tubular Transformations

    Science.gov (United States)

    Sola, F.; Lebron-Colon, M.; Ferreira, P. J.; Fonseca, L. F.; Meador, M. A.; Marin, C.

    2010-01-01

    Single-walled carbon nanotubes (SWCNTs) prepared by the HiPco process were purified using a modified gas phase purification technique. A TEM-STM holder was used to study the morphological changes of SWCNT ropes as a function of applied voltage. Kink formation, buckling behavior, tubular transformation and eventual breakdown of the system were observed. The tubular formation was attributed to a transformation from SWCNT ropes to multi-walled carbon nanotube (MWCNT) structures. It is likely mediated by the patching and tearing mechanism which is promoted primarily by the mobile vacancies generated due to current-induced heating and, to some extent, by electron irradiation.

  11. Nanoprecipitates in single-crystal molybdenum-alloy nanopillars detected by TEM and atom probe tomography

    International Nuclear Information System (INIS)

    Oveisi, Emad; Bártová, Barbora; Gerstl, Stephan; Zimmermann, Julien; Marichal, Cécile; Van Swygenhoven, Helena; Hébert, Cécile

    2013-01-01

    Transmission electron microscopy (TEM) supported by various chemical analyses techniques as well as atom probe tomography is applied to characterize newly identified nanosized precipitates in Mo-alloy nanopillars that were prepared by directional solidification. It is shown that the α-Mo matrix contains Al-enriched face-centred cubic precipitates which have a 4.12 Å lattice parameter, and exhibit a Kurdjumov–Sachs crystallographic orientation relationship with the matrix. Such precipitates could be responsible for the unusual behaviour of the pillars during compression tests

  12. In Situ TEM Creation and Electrical Characterization of Nanowire Devices

    DEFF Research Database (Denmark)

    Kallesøe, Christian; Wen, Cheng-Yen; Booth, Timothy J.

    2012-01-01

    bridge devices in situ and relate these to the structure. We also describe processes to modify the contact and the nanowire surface after device formation. The technique we describe allows the direct analysis of the processes taking place during device formation and use, correlating specific nanoscale......We demonstrate the observation and measurement of simple nanoscale devices over their complete lifecycle from creation to failure within a transmission electron microscope. Devices were formed by growing Si nanowires, using the vapor–liquid–solid method, to form bridges between Si cantilevers. We...... structural and electrical parameters on an individual device basis....

  13. A casting and imaging technique for determining void geometry and relative permeability behavior of a single fracture specimen

    Energy Technology Data Exchange (ETDEWEB)

    Cox, B.L.; Pruess, K.; Persoff, P.

    1990-01-01

    A casting technique has been developed for making translucent replicas of the void space of natural rock fractures. Attenuation of light shined through the cast combined with digital image analysis provides a pointwise definition of fracture apertures. The technique has been applied to a fracture specimen from Dixie Valley, Nevada, and the measured void space geometry has been used to develop theoretical predictions of two-phase relative permeability. A strong anisotropy in relative permeabilities has been found, which is caused by highly anisotropic spatial correlations among fracture apertures. 16 refs., 6 figs.

  14. Environmental Monitoring Techniques and Equipment related to the installation and operation of Marine Energy Conversion Systems

    International Nuclear Information System (INIS)

    Scanu, Sergio; Carli, Filippo Maria; Piermattei, Viviana; Bonamano, Simone; Paladini de Mendoza, Francesco; Marcelli, Marco; Peviani, Maximo Aurelio; Dampney, Keith; Norris, Jennifer

    2015-01-01

    Results of activities under project Marine Renewables Infrastructure Network for Emerging Energy Technologies (MaRINET) are reported, which led to DEMTE, a database, created on the basis of standardized monitoring of the marine environment during installation, operation and decommissioning of Marine Energy Conversion Systems. Obtained with the consortium partners’ available techniques and equipment, the database shows that such instruments cover all identified marine environmental compartments, despite the lack of underwater vehicles and the reduced skills in using satellite technologies. These weaknesses could be overcome by an accurate planning of equipment, techniques and knowledge sharing. The approach here presented also leads to an effective analysis even in non-marine contexts

  15. Embroidery and Related Manufacturing Techniques for Wearable Antennas: Challenges and Opportunities

    Directory of Open Access Journals (Sweden)

    Aris Tsolis

    2014-05-01

    Full Text Available This paper will review the evolution of wearable textile antennas over the last couple of decades. Particular emphasis will be given to the process of embroidery. This technique is advantageous for the following reasons: (i bespoke or mass produced designs can be manufactured using digitized embroidery machines; (ii glue is not required and (iii the designs are aesthetic and are integrated into clothing rather than being attached to it. The embroidery technique will be compared to alternative manufacturing processes. The challenges facing the industrial and public acceptance of this technology will be assessed. Hence, the key opportunities will be highlighted.

  16. EBSD and FIB/TEM examination of shape memory effect deformation structures in U-14 at.% Nb

    Energy Technology Data Exchange (ETDEWEB)

    Clarke, A.J. [Materials Science and Technology Division, Mail Stop G770, Los Alamos National Laboratory, Los Alamos, NM 87545 (United States)], E-mail: aclarke@lanl.gov; Field, R.D.; McCabe, R.J.; Cady, C.M.; Hackenberg, R.E.; Thoma, D.J. [Materials Science and Technology Division, Mail Stop G770, Los Alamos National Laboratory, Los Alamos, NM 87545 (United States)

    2008-06-15

    Detailed examinations of shape memory effect (SME) deformation structures in martensite of U-14 at.% Nb were performed with electron backscatter diffraction (EBSD) and transmission electron microscopy (TEM). An accommodation strain analysis, which has been previously used to predict SME deformation structures and texture evolution in polycrystalline material, was also performed. Martensite variants and twin relationships observed with EBSD after compressive or tensile deformation were determined to be consistent with those expected from calculated accommodation strains. Focused ion beam (FIB) was used to select twinned regions identified with EBSD for more detailed TEM analysis to verify the presence of these specific twins. The observed SME twinning systems in the martensite agree with previous TEM observations and the predicted {l_brace}1-bar76{r_brace} twinning system was observed experimentally for the first time in U-14 at.% Nb using these complementary techniques.

  17. In situ TEM study of the coarsening of carbon black supported Pt nanoparticles in hydrogen

    DEFF Research Database (Denmark)

    Simonsen, Søren Bredmose; Wang, Yan; Jensen, Jens Oluf

    2017-01-01

    The control of sizes and shapes of nanostructures is of tremendous importance for the catalytic activity in electrochemistry and in catalysis more generally. However, due to relatively large surface free energies, nanostructures often sinter to form coarser and more stable structures that may...... not have the intended physicochemical properties. Pt is known to be a very active catalyst in several chemical reactions and for example as carbon supported nanoparticles in fuel cells. The presentation focusses on coarsening mechanisms of Pt nanoparticles supported on carbon black during exposure...... to hydrogen. By means of in situ transmission electron microscopy (TEM), Pt nanoparticle coarsening was monitored in 6 mbar 20 % H2/Ar while ramping up the temperature to ca. 900 °C. Time-resolved TEM images directly reveal that separated ca. 3 nm sized Pt nanoparticles in the pure hydrogen environment...

  18. A TEM method for analyzing local strain fields in irradiated materials

    International Nuclear Information System (INIS)

    Bennetch, J.I.; Jesser, W.A.

    1983-01-01

    Of great interest to the field of fracture mechanics is the strain field in front of a crack tip. In irradiated materials, cavities which naturally form as a result of radiation provide convenient internal markers. If a miniaturized irradiated tensile sample is pulled in situ in a transmission electron microscope (TEM), both the relative displacement of these cavities and their distortion in shape provide information on localized strain on a microscopic level. In addition, the TEM method allows direct correlation of active slip systems with crack propagation characteristics. To illustrate this method a strain field map was constructed about a crack propagating in a helium irradiated type 316 stainless steel sample containing large cavities. (orig.)

  19. Capillary electrokinetic separation techniques for profiling of drugs and related products

    NARCIS (Netherlands)

    Hilhorst, M.J; Somsen, G.W; de Jong, G.J.

    Capillary electrokinetic separation techniques offer high efficiency and peak capacity, and can be very useful for the analysis of samples containing a large variety of (unknown) compounds. Such samples are frequently met in impurity profiling of drugs (detection of potential impurities in a

  20. A relative quantitative assessment of myocardial perfusion by first-pass technique: animal study

    Science.gov (United States)

    Chen, Jun; Zhang, Zhang; Yu, Xuefang; Zhou, Kenneth J.

    2015-03-01

    The purpose of this study is to quantitatively assess the myocardial perfusion by first-pass technique in swine model. Numerous techniques based on the analysis of Computed Tomography (CT) Hounsfield Unit (HU) density have emerged. Although these methods proposed to be able to assess haemodynamically significant coronary artery stenosis, their limitations are noticed. There are still needs to develop some new techniques. Experiments were performed upon five (5) closed-chest swine. Balloon catheters were placed into the coronary artery to simulate different degrees of luminal stenosis. Myocardial Blood Flow (MBF) was measured using color microsphere technique. Fractional Flow Reserve (FFR) was measured using pressure wire. CT examinations were performed twice during First-pass phase under adenosine-stress condition. CT HU Density (HUDCT) and CT HU Density Ratio (HUDRCT) were calculated using the acquired CT images. Our study presents that HUDRCT shows a good (y=0.07245+0.09963x, r2=0.898) correlation with MBF and FFR. In receiver operating characteristic (ROC) curve analyses, HUDRCT provides excellent diagnostic performance for the detection of significant ischemia during adenosine-stress as defined by FFR indicated by the value of Area Under the Curve (AUC) of 0.927. HUDRCT has the potential to be developed as a useful indicator of quantitative assessment of myocardial perfusion.

  1. A Diagnostic Technique for Formulating Market Strategies in Higher Education Based on Relative Competitive Position.

    Science.gov (United States)

    Dolinsky, Arthur L.; Quazi, Hesan A.

    1994-01-01

    Importance-performance analysis, a marketing research technique using analysis of consumer attitudes toward salient product or service attributes, is found useful for colleges and universities in developing marketing strategies, particularly when competition is considered as an important dimension. Data are drawn from a survey of 252 students at 1…

  2. Objective function analysis for electric soundings (VES), transient electromagnetic soundings (TEM) and joint inversion VES/TEM

    Science.gov (United States)

    Bortolozo, Cassiano Antonio; Bokhonok, Oleg; Porsani, Jorge Luís; Monteiro dos Santos, Fernando Acácio; Diogo, Liliana Alcazar; Slob, Evert

    2017-11-01

    Ambiguities in geophysical inversion results are always present. How these ambiguities appear in most cases open to interpretation. It is interesting to investigate ambiguities with regard to the parameters of the models under study. Residual Function Dispersion Map (RFDM) can be used to differentiate between global ambiguities and local minima in the objective function. We apply RFDM to Vertical Electrical Sounding (VES) and TEM Sounding inversion results. Through topographic analysis of the objective function we evaluate the advantages and limitations of electrical sounding data compared with TEM sounding data, and the benefits of joint inversion in comparison with the individual methods. The RFDM analysis proved to be a very interesting tool for understanding the joint inversion method of VES/TEM. Also the advantage of the applicability of the RFDM analyses in real data is explored in this paper to demonstrate not only how the objective function of real data behaves but the applicability of the RFDM approach in real cases. With the analysis of the results, it is possible to understand how the joint inversion can reduce the ambiguity of the methods.

  3. Intelligent Prediction of Soccer Technical Skill on Youth Soccer Player's Relative Performance Using Multivariate Analysis and Artificial Neural Network Techniques

    OpenAIRE

    Abdullah, M. R; Maliki, A. B. H. M; Musa, R. M; Kosni, N. A; Juahir, H

    2016-01-01

    This study aims to predict the potential pattern of soccer technical skill on Malaysia youth soccer players relative performance using multivariate analysis and artificial neural network techniques. 184 male youth soccer players were recruited in Malaysia soccer academy (average age = 15.2±2.0) underwent to, physical fitness test, anthropometric, maturity, motivation and the level of skill related soccer. Unsupervised pattern recognition of principal component analysis (PCA) was used to ident...

  4. The Relationship between Instructor Misbehaviors and Student Antisocial Behavioral Alteration Techniques: The Roles of Instructor Attractiveness, Humor, and Relational Closeness

    Science.gov (United States)

    Claus, Christopher J.; Booth-Butterfield, Melanie; Chory, Rebecca M.

    2012-01-01

    Using rhetorical/relational goal theory as a guiding frame, we examined relationships between instructor misbehaviors (i.e., indolence, incompetence, and offensiveness) and the likelihood of students communicating antisocial behavioral alteration techniques (BATs). More specifically, the study focused on whether students' perceptions of instructor…

  5. Usefulness of the 'Rendezvous' Technique in Living Related Right Liver Donors with Postoperative Biliary Leakage from Bile Duct Anastomosis

    International Nuclear Information System (INIS)

    Miraglia, R.; Traina, M.; Maruzzelli, L.; Caruso, S.; Di Pisa, M.; Gruttadauria, S.; Luca, A.; Gridelli, B.

    2008-01-01

    This is a report on two cases of large bile leak following right hepatectomy performed for living related liver transplantation, originating from the stump of the ligated right bile duct, and treated with the placement of large percutaneous biliary catheters through a combined percutaneous transhepatic and endoscopic approach (rendezvous technique).

  6. The relation of plasma octopamine to hepatic encephalopathy studied with stable isotope dilution technique

    International Nuclear Information System (INIS)

    Zhang Jianhua

    1992-01-01

    In order to investigate the relationship between octopamine and hepatic encephalopathy, plasma octopamine content of normal adults and hepatic patients (compensated or de-compensated cirrhotic, patients with encephalopathy) were determined with isotope dilution and GCMS technique, 200 ng of [1, 1-D]-octopamine was added to each sample as internal standard. After the de-proteinized plasma was subjected to cation exchange chromatography, the amine fraction was derivatized with PFP and analyzed with GCMS using the selected ion monitoring technique. The result showed that the level of plasma octopamine was significantly elevated in patients with encephalopathy. Since this method is sensitive and specific, it is readily applicable to the analysis of a few nano grams of octopamine

  7. Multivariate analysis of remote LIBS spectra using partial least squares, principal component analysis, and related techniques

    Energy Technology Data Exchange (ETDEWEB)

    Clegg, Samuel M [Los Alamos National Laboratory; Barefield, James E [Los Alamos National Laboratory; Wiens, Roger C [Los Alamos National Laboratory; Sklute, Elizabeth [MT HOLYOKE COLLEGE; Dyare, Melinda D [MT HOLYOKE COLLEGE

    2008-01-01

    Quantitative analysis with LIBS traditionally employs calibration curves that are complicated by the chemical matrix effects. These chemical matrix effects influence the LIBS plasma and the ratio of elemental composition to elemental emission line intensity. Consequently, LIBS calibration typically requires a priori knowledge of the unknown, in order for a series of calibration standards similar to the unknown to be employed. In this paper, three new Multivariate Analysis (MV A) techniques are employed to analyze the LIBS spectra of 18 disparate igneous and highly-metamorphosed rock samples. Partial Least Squares (PLS) analysis is used to generate a calibration model from which unknown samples can be analyzed. Principal Components Analysis (PCA) and Soft Independent Modeling of Class Analogy (SIMCA) are employed to generate a model and predict the rock type of the samples. These MV A techniques appear to exploit the matrix effects associated with the chemistries of these 18 samples.

  8. Techniques for Reducing Consistency-Related Communication in Distributed Shared Memory System

    OpenAIRE

    Zwaenepoel, W; Bennett, J.K.; Carter, J.B.

    1995-01-01

    Distributed shared memory 8DSM) is an abstraction of shared memory on a distributed memory machine. Hardware DSM systems support this abstraction at the architecture level; software DSM systems support the abstraction within the runtime system. One of the key problems in building an efficient software DSM system is to reduce the amount of communication needed to keep the distributed memories consistent. In this paper we present four techniques for doing so: 1) software release consistency; 2)...

  9. Hyphenated techniques in multidimensional gas chromatography for analysis of wine aroma and related odorants

    OpenAIRE

    Chin, Sung Tong

    2017-01-01

    The advent of analytical multidimensional gas chromatography (MDGC) techniques, with recent development in comprehensive two-dimensional gas chromatography (GC×GC) as well as microfluidic technology in conventional heart-cut MDGC, has achieved excellent separation efficiency for advanced characterization of complex volatile and semi-volatile samples, which is unlikely to be accomplished by single dimensional chromatography. This dissertation work has highlighted the potential opportunities fo...

  10. Challenges in TEM sample preparation of solvothermally grown CuInS2 films.

    Science.gov (United States)

    Frank, Anna; Changizi, Rasa; Scheu, Christina

    2018-06-01

    Transmission electron microscopy (TEM) is a widely used tool to characterize materials. The required samples need to be electron transparent which should be achieved without changing the microstructure. This work describes different TEM sample preparation techniques of nanostructured CuInS 2 thin films on fluorine-doped tin oxide substrates, synthesized solvothermally using l-cysteine as sulfur source. Focused ion beam lamellae, conventional cross section samples and scratch samples have been prepared and investigated. It was possible to prepare appropriate samples with each technique, however, each technique brings with it certain advantages and disadvantages. FIB preparation of solvothermally synthesized CuInS 2 suffers from two main drawbacks. First, the whole CuInS 2 layer displays a strongly increased Cu content caused by Cu migration and preferential removal of In. Further, electron diffraction shows the formation of an additional CuS phase after Ga + bombardment. Second, diffraction analysis is complicated by a strong contribution of crystalline Pt introduced during the FIB preparation and penetrating into the porous film surface. The conventional cross sectional CuInS 2 sample also shows a Cu signal enhancement which is caused by contribution of the brass tube material used for embedding. Additionally, Cu particles have been observed inside the CuInS 2 which have been sputtered on the film during preparation. Only the scratch samples allow an almost artefact-free and reliable elemental quantification using energy-dispersive X-ray spectroscopy. However, scratch samples suffer from the drawback that it is not possible to determine the layer thickness, which is possible for both cross sectional preparation techniques. Consequently, it is concluded that the type of sample preparation should be chosen dependent on the required information. A full characterization can only be achieved when the different techniques are combined. Copyright © 2018 Elsevier Ltd. All

  11. Easy process to obtain suspended graphene flakes on TEM grids

    International Nuclear Information System (INIS)

    Gonçalves, Hugo; Fernandes, Joel; Moura, Cacilda; Schellenberg, Peter; Belsley, Michael; Alves, Luís

    2015-01-01

    Much of the ongoing research on graphene requires free-hanging (suspended) graphene to eliminate any influence from underlying substrates. Several methods have been developed for its preparation but they are either very complex or not completely reliable. Here, we describe a simple method for the transfer of graphene single layers from glass or silicon substrates onto TEM grids. The method uses a carrier film for the transfer process. By optimizing the process yields greater than 60% were achieved. The integrity of the transferred films was confirmed using Raman spectroscopy; successful suspension of both mono- and double-layer graphene sheets was obtained. (paper)

  12. In-situ TEM characterization of nanomaterials and devices

    KAUST Repository

    Kim, Moon; Park, Seongyong; Cha, Dong Kyu; Kim, Jiyoung; Floresca, Herman Carlo; Lu, Ning; Wang, Jinguo

    2011-01-01

    Electrical properties of nano size devices were directly measured by TEM. Real time observation of phase transition behavior in PRAM revealed that the volume of the crystalline phase is the main factor in determining cell resistance. In the transistor device, we have identified the doping type and area by measuring the I-V curve at the individual nano contact on the specimen. The evolution of the graphene edge structure was controlled and monitored at and up to 1200°C in-situ. © 2011 IEEE.

  13. TEM observations of HT-9 as-welded weldment microstructures

    International Nuclear Information System (INIS)

    Foulds, J.R.; Lechtenberg, T.A.

    1984-01-01

    TEM studies of different locations in an HT-9 weldment indicated delta-ferrite (delta) occurrence, M 23 C 6 precipitation at delta-martensite interfaces, fine carbide precipitation at prior austenite grain boundaries, and martensite lath and lath packet size to be the distinguishable microstructure features observed. Furthermore, retained austenite films were observed in the weld metal and the HAZ adjacent to the weld metal that reached the highest temperature during joining. The microstructures correlate well with the observed room temperature microhardness except for the fusion boundary in weld metal which exhibited a hardness drop and an unexpected minimum amount of delta-ferrite

  14. Microfabricated Nanofluidic cells for in situ liquid TEM

    DEFF Research Database (Denmark)

    Laganà, Simone

    Over the last decade, transmission electron microscopy (TEM) has been revolutionized not only by the introduction of new and very sophisticated hardware for improved resolution, such as aberration correctors and monochromators, but also by the improvement of new methods that have provided more than......, allowing quantitative and high-precision acquisition of liquid thickness maps, high resolution observations and meaningful information about synthesis of NPs from metal precursor solutions in confined space. Finally, a new concept device based on a Si3N4 membrane for plunge freezing fixation, which enables...

  15. Shear Punch Testing of BOR-60 Irradiated TEM Specimens

    Energy Technology Data Exchange (ETDEWEB)

    Saleh, Tarik A. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Quintana, Matthew Estevan [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Romero, Tobias J. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-06-13

    As a part of the project “High Fidelity Ion Beam Simulation of High Dose Neutron Irradiation” an Integrated Research Program (IRP) project from the U.S. Department of Energy, Nuclear Energy University Programs (NEUP), TEM geometry samples of ferritic cladding alloys, Ni based super alloys and model alloys were irradiated in the BOR-60 reactor to ~16 dpa at ~370°C and ~400°C. Samples were sent to Los Alamos National Laboratory and subjected to shear punch testing. This report presents the results from this testing.

  16. TEM INVESTIGATIONS OF WC-Co ALLOYS AFTER CREEP EXPERIMENTS

    OpenAIRE

    Lay , S.; Osterstock , F.; Vicens , J.

    1986-01-01

    Carbide tungsten cobalt alloys were deformed in compression or in three point bending in a temperature range 1000-1350°C and in a stress domain 30-1000MPa. In these conditions, the stress exponent n of WC-Co alloys is a function of only the cobalt volumic ratio and tends towards n = 1 for pure carbide. The apparent activation energy is 550 kj mole-1. T.E.M. investigations on pure carbide deformed at 1450°C show an extensive intragranular deformation. Analysis of these defects have been perfor...

  17. In-situ TEM characterization of nanomaterials and devices

    KAUST Repository

    Kim, Moon

    2011-10-01

    Electrical properties of nano size devices were directly measured by TEM. Real time observation of phase transition behavior in PRAM revealed that the volume of the crystalline phase is the main factor in determining cell resistance. In the transistor device, we have identified the doping type and area by measuring the I-V curve at the individual nano contact on the specimen. The evolution of the graphene edge structure was controlled and monitored at and up to 1200°C in-situ. © 2011 IEEE.

  18. Diagrams and Relational Maps: The Use of Graphic Elicitation Techniques with Interviewing for Data Collection, Analysis, and Display

    Directory of Open Access Journals (Sweden)

    Andrea J. Copeland PhD

    2012-12-01

    Full Text Available Graphic elicitation techniques, which ask research participants to provide visual data representing personal understandings of concepts, experiences, beliefs, or behaviors, can be especially useful in helping participants to express complex or abstract ideas or opinions. The benefits and drawbacks of using graphic elicitation techniques for data collection, data analysis, and data display in qualitative research studies are analyzed using examples from a research study that employed data matrices and relational maps in conjunction with semi-structured interviews. Results from this analysis demonstrate that the use of these combined techniques for data collection facilitates triangulation and helps to establish internal consistency of data, thereby increasing the trustworthiness of the interpretation of that data and lending support to validity and reliability claims. Findings support the notion that graphic elicitation techniques can be highly useful in qualitative research studies at the data collection, the data analysis, and the data reporting stages. For example, this study found that graphic elicitation techniques are especially useful for eliciting data related to emotions and emotional experiences.

  19. A Mindfulness-Based Decentering Technique Increases the Cognitive Accessibility of Health and Weight Loss Related Goals

    Directory of Open Access Journals (Sweden)

    Katy Tapper

    2018-04-01

    Full Text Available Previous research has shown that a mindfulness-based decentering technique can help individuals resist eating chocolate over a 5-day period. However, it is unclear how this technique exerts its effect. This study explored one potential mechanism; that decentering increases the cognitive accessibility of relevant goals. Male and female participants (n = 90 spent 5 min practicing either a decentering or relaxation (control technique. They then viewed a picture of a chocolate bar for 3 min whilst either applying the decentering technique or letting their mind wander (control. Finally, all participants completed 20 letter strings, rated their motivation for weight loss and for healthy eating, and indicated whether or not they were dieting to lose weight. As predicted, those who had applied the decentering technique produced a greater number of health and weight loss related words when completing the letter strings, compared to those who had simply let their mind wander (p < 0.001. However, contrary to predictions, these effects were not significantly greater amongst those who were more motivated to lose weight or eat healthily, or amongst those who were dieting to lose weight, though the means were in the predicted directions. The results suggest that this particular mindfulness technique may increase the accessibility of relevant goals. Further research would be needed to (a compare effects with other strategies that prompt individuals to remember their goals, (b examine other potential mechanisms of action, and (c confirm that effects on self-control are mediated by increased goal accessibility.

  20. Long-Term Evaluation of Changes in Operative Technique and Hardware-Related Complications With Deep Brain Stimulation.

    Science.gov (United States)

    Falowski, Steven M; Ooi, Yinn Cher; Bakay, Roy A E

    2015-12-01

    Deep brain stimulation is the most frequent neurosurgical procedure for movement disorders. While this elective procedure carries a low-risk profile, it is not free of complications. As a new procedure, the pattern of complications changed with experience and modification of surgical technique and equipment. This review analyzes the most common hardware-related complications that may occur and techniques to avoid them. It is a retrospective review of 432 patients undergoing 1077 procedures over a 14-year period by one surgeon with emphasis on the analysis of surgical technique and the changes over time. Comparisons were made pre and postimplementation of different surgical techniques over different time periods. The epochs relate to the learning curve, new equipment, and new techniques. Overall lead revision was observed at 5.7%, extension revision at 3.2%, infection rate at 1.2%, infarct without intracerebral hemorrhage at 0.8%, and intracerebral hemorrhage at 2.5% with a permanent deficit of 0.2%. An analysis and change in surgical technique which involved isolating the lead from the skin surface at both the cranial and retro-auricular incision also demonstrated a substantial decrease in lead fracture rate and infection rate. There was no mortality. This large series of patients and long-term follow-up demonstrates that risks are very low in comparison with other neurosurgical procedures, but DBS is still an elective procedure that necessitates extensive care and precision. In a rapidly evolving field, attention to surgical technique is imperative and will keep rates of complications at a minimum. © 2015 International Neuromodulation Society.

  1. Differential dependence on N-glycosylation of anthrax toxin receptors CMG2 and TEM8.

    Directory of Open Access Journals (Sweden)

    Sarah Friebe

    Full Text Available ANTXR 1 and 2, also known as TEM8 and CMG2, are two type I membrane proteins, which have been extensively studied for their role as anthrax toxin receptors, but with a still elusive physiological function. Here we have analyzed the importance of N-glycosylation on folding, trafficking and ligand binding of these closely related proteins. We find that TEM8 has a stringent dependence on N-glycosylation. The presence of at least one glycan on each of its two extracellular domains, the vWA and Ig-like domains, is indeed necessary for efficient trafficking to the cell surface. In the absence of any N-linked glycans, TEM8 fails to fold correctly and is recognized by the ER quality control machinery. Expression of N-glycosylation mutants reveals that CMG2 is less vulnerable to sugar loss. The absence of N-linked glycans in one of the extracellular domains indeed has little impact on folding, trafficking or receptor function of the wild type protein expressed in tissue culture cells. N-glycans do, however, seem required in primary fibroblasts from human patients. Here, the presence of N-linked sugars increases the tolerance to mutations in cmg2 causing the rare genetic disease Hyaline Fibromatosis Syndrome. It thus appears that CMG2 glycosylation provides a buffer towards genetic variation by promoting folding of the protein in the ER lumen.

  2. Cassette-based in-situ TEM sample inspection in the dual-beam FIB

    International Nuclear Information System (INIS)

    Kendrick, A B; Moore, T M; Zaykova-Feldman, L; Amador, G; Hammer, M

    2008-01-01

    A novel method is presented, combining site-specific TEM sample preparation and in-situ STEM analysis in a dual-beam microscope (FIB/SEM) fitted with a chamber mounted nano-manipulator. TEM samples are prepared using a modified in-situ, lift-out method, whereby the samples are thinned and oriented for immediate in-situ STEM analysis using the tilt, translation, and rotation capabilities of a FIB/SEM sample stage, a nano-manipulator, and a novel cassette. This cassette can provide a second tilt axis, orthogonal to the stage tilt axis, so that the STEM image contrast can be optimized to reveal the structural features of the sample (true STEM imaging in the FIB/SEM). The angles necessary for stage rotation and probe shaft rotation are calculated based on the position of the nano-manipulator relative to the stage and door and the stage tilt angle. A FIB/SEM instrument, equipped with a high resolution scanning electron column, can provide sufficiently high image resolution to enable many failure analysis and process control applications to be successfully carried out without requiring the use of a separate dedicated TEM/STEM instrument. The benefits of this novel approach are increased throughput and reduced cost per sample. Comparative analysis of different sample preparation methods is provided, and the STEM images obtained are shown.

  3. Multi-component and multi-array TEM detection in karst tunnels

    International Nuclear Information System (INIS)

    Sun, Huaifeng; Li, Shucai; Su, Maoxin; Xue, Yiguo; Li, Xiu; Qi, Zhipeng

    2012-01-01

    Emerging applications of transient electromagnetic methods (TEM) in tunnelling require higher resolution on the distributions and shapes of low resistivity bodies, such as karst water and karst pipes, using multi-component and multi-array receivers. However, there are no apparent resistivity definitions for both vertical and horizontal components with offsets inside the loop. Although the raw field can show the differences of the earth electric structure, it is not straightforward. Apparent resistivity is very convenient and easy for engineers. We have developed a method for multi-component and multi-array TEM which can be applied in tunnelling and defined the expressions of apparent resistivity. This method takes advantage of the difference in resolution among components. A homogeneous half-space model and four typical three-layered models are used to test the effectiveness of the new definition. A field case history is carried out and analysed to demonstrate the viability of this technique. The results suggest that it is feasible to use the technique in tunnelling, especially for identifying the spatial distribution of karst water and karst pipes. (paper)

  4. APFIM and TEM investigations of precipitation in rapidly solidified 316 stainless steel

    International Nuclear Information System (INIS)

    Wisutmethangoon, S.; Kelly, T.F.; Flinn, J.E.; Camus, P.P.

    1998-01-01

    316 stainless steel has been rapid solidification-processed (RSP) by gas atomization and hot extrusion of the powder with the intent of improving the mechanical properties through fine-scale precipitation. Vanadium, nitrogen and oxygen have been introduced intentionally as alloying elements for this purpose. The yield strength after solution heat treatment of the RSP alloy is 450 MPa. By ageing at 600 C for 1000 h, the yield strength increases to 615 MPa with little loss of ductility (53% reduction of area). The ultimate tensile strength after cold work and ageing is 922 MPa. The morphology and composition of the precipitates in this steel have been investigated using APFIM and TEM techniques in order understand the origin of the high strength. A high numbered density (∼2 x 10 21 m -3 ) of 25 nm plate-like precipitates was observed with TEM in an aged specimen. The composition of these precipitates was analyzed using APFIM techniques, and was found to be a complex nitride of Cr, V, Fe, Ni and Mo. This nitride precipitate was not found in an unaged specimen of this alloy. These precipitates are responsible for improving mechanical properties by dispersion strengthening. (orig.)

  5. Public Relations for Brazilian Libraries: Process, Principles, Program Planning, Planning Techniques and Suggestions.

    Science.gov (United States)

    Kies, Cosette N.

    A brief overview of the functions of public relations in libraries introduces this manual, which provides an explanation of the public relations (PR) process, including fact-finding, planning, communicating, evaluating, and marketing; some PR principles; a 10-step program that could serve as a model for planning a PR program; a discussion of PR…

  6. Sintering of oxide-supported Pt and Pd nanoparticles in air studied by in situ TEM

    DEFF Research Database (Denmark)

    Simonsen, Søren Bredmose

    This thesis presents a fundamental study of the sintering of supported nanoparticles in relation to diesel oxidation catalysts. The sintering of supported nanoparticles is an important challenge in relation to this catalyst, as well as many other catalyst systems, and a fundamental understanding...... of Pt, Pd and bimetallic Pt-Pd nanoparticles supported on a flat and homogeneous Al2O3 or SiO2 surface. By using in situ TEM on the planar model catalysts it was possible to directly monitor the detailed dynamical changes of the individual nanoparticles during exposure to oxidizing conditions...

  7. Proceedings of VII International Symposium on Nuclear and Related Techniques. XIII Workshop on Nuclear Physics. WONP-NURT 2011

    International Nuclear Information System (INIS)

    2011-02-01

    This year the XIII Workshop on Nuclear Physics (WONP) and the VII Symposium on Nuclear and Related Techniques (NURT) are organized jointly, by Instituto Superior de Tecnologias y Ciencias Aplicadas and Centro de Aplicaciones Tecnologicas y Desarrollo Nuclear. Both events gather scientists from several countries with top research work on nuclear physics and its applications. WONP has been carried out since 1994 promoting an ever-exchanging exchange between professionals of various nuclear and applied physics fields, those related to environmental and health care. NURT is one of the key Cuban scientific meetings since 1997 dealing with the peaceful applications of nuclear techniques in several domains of the society. WONP and NURT provide an unique opportunity for the national and international scientific community to meet outstanding researchers and discuss current trends in several areas of theoretical, experimental and applied nuclear physics and related topics. The papers submitted to this event are presented in this CD-ROM

  8. Proceedings of VI International Symposium on Nuclear and Related Techniques. XII Workshop on Nuclear Physics. WONP-NURT 2009

    International Nuclear Information System (INIS)

    2009-02-01

    This year the XII Workshop on Nuclear Physics (WONP) and the VI Symposium on Nuclear and Related Techniques (NURT) are organized jointly, by Instituto Superior de Tecnologias y Ciencias Aplicadas and Centro de Aplicaciones Tecnologicas y Desarrollo Nuclear. Both events gather scientists from several countries with top research work on nuclear physics and its applications. WONP has been carried out since 1994 promoting an ever-exchanging exchange between professionals of various nuclear and applied physics fields, those related to environmental and health care. NURT is one of the key Cuban scientific meetings since 1997 dealing with the peaceful applications of nuclear techniques in several domains of the society. WONP and NURT provide an unique opportunity for the national and international scientific community to meet outstanding researchers and discuss current trends in several areas of theoretical, experimental and applied nuclear physics and related topics. The papers submitted to this event are presented in this CD-ROM

  9. RAF 7015: Strengthening Regional Capacities for Marine Risk Assessment Using Nuclear and Related Techniques

    International Nuclear Information System (INIS)

    Okuku, E.; Mwangi, S.

    2017-01-01

    To develop and implement harmonized and integrated regional sea food safety monitoring in the MS through the application of nuclear techniques for enhanced sustainability of marine resource. Rapid urbanization and industrialization are causing alterations of the characteristics of marine environment thus threatening the ecosystem health and sustainability of marine environment and Affects public health, recreational water quality and economic viability.Threats to marine ecosystem include Over-exploitation, habitat destruction, Global warming- rise in SST, HABs and invasive species, Ocean acidification and Marine pollution

  10. Framework for regional environmental management. [Problem-solving techniques; public relations

    Energy Technology Data Exchange (ETDEWEB)

    Sievering, H.; Sinopoli, J.

    1976-04-01

    A framework for environmental decision-making is described in which both qualitative and quantitative aspects of regional problems can be integrated into a problem-solving context. The techniques employed in this framework are computer simulation, games, and vote-trading. The paper concludes that through this framework: (a) environmental analysts can assess public value structure goal sets which can be used in the development of regional simulations, and (b) in turn, the quantitative aspects of the problems will be more easily communicated to the affected public. A brief description of the application of the framework is also presented.

  11. TEM and EELS study of deuterated carbon: application to the fuel retention in tokamaks; Etude couplee MET-EELS du carbone deutere: application a la retention du combustible dans les tokamaks

    Energy Technology Data Exchange (ETDEWEB)

    Bernier, N

    2007-12-15

    We developed a methodology, based on the combination of TEM and EELS techniques, for a structural and chemical characterization, at a high spatial resolution, of a wide range of carbon materials. We i) optimized, in the framework of theoretical models, the sp2 fraction quantification from pure carbons by EELS ii) transferred this quantification to deuterated amorphous carbon layers iii) showed, from graphitized carbons, how the TEM-EELS combination allows to detect low concentrations of implanted D. Due to the accomplishment of these developments, we applied our approach to the study of D retention in composites C/C, which are the plasma-facing materials in TS. We showed that specific localized retention sites correspond to relatively large ({approx} 3 mm.) cracks between fibres and matrix; such cracks offer a simple and direct path for deuterated amorphous carbon. The particle balance performed in TS is discussed in the light of this trapping mechanism. (author)

  12. Atmospheric deposition of heavy metals in transilvanian plateau of romania studied by the moss bio monitoring Technique employing nuclear and related analytical Techniques and gis technology

    International Nuclear Information System (INIS)

    Lucaciu, Adriana; Craciun, L.; Cuculeanu, V.; Eseanu, D.

    2001-01-01

    This paper presents data for 39 elements of 69 moss samples (Hypnum cupressiforme) collected in the Transilvanian Plateau of Romania. This results have obtained in the framework of the project Atmospheric Deposition of Heavy Metals in Rural and Urban Areas of Romania Studied by the Moss Bio monitoring Technique Employing Nuclear and Related Analytical Techniques and GIS Technology carried out under the auspices of the International Atomic Energy Agency, Vienna.The samples collected have been analyzed by ENAA with the exception of Cu, Cd, and Pb which were determined by AAS. IAEA certified materials were used to ensure the quality of the measurements. The regional concentration variations of selected elements are presented in the form of maps constructed by GIS technology. Extremely high values are observed for elements such as Cu, Zn, As and Sb in parts of this territory affected by local metal industries. The levels are among the highest observed in the world, and could be partly responsible for the unfortunate health situation in some of these areas

  13. Complications of transanal endoscopic microsurgery (TEMS): a prospective audit.

    Science.gov (United States)

    Bignell, M B; Ramwell, A; Evans, J R; Dastur, N; Simson, J N L

    2010-07-01

    The aim of this study was to determine the postoperative complications of Transanal Endoscopic Microsurgery (TEMS) excision of rectal lesions. A prospective audit of 262 consecutive TEMS procedures performed by a single surgeon between 1999 and 2008. The mean age of patients was 72 years. The mean area of the lesions excised was 17.5 cm(2) with a mean diameter of 4.5 cm at a mean distance of 7.4 cm from the dentate line. There were 201 full thickness excisions, 51 partial thickness excisions and nine were mixed or unclassified. Thirty-three (13%) patients developed 41 complications. There were two (0.8%) deaths within 30 days. Pelvic sepsis occurred in seven (3%) patients and was significantly more common after excision of low lesions within 2 cm of the dentate line. Postoperative haemorrhage occurred in seven (3%) patients and was significantly less common when dissection was performed with ultrasonic dissection than with diathermy. Fourteen (5%) patients developed acute urinary retention. Four (1.5%) patients developed rectal stenosis and four (1.5%) suffered uncomplicated surgical emphysema that required no treatment. Transanal endoscopic microsurgery is a safe operation with a low mortality and morbidity. Pelvic sepsis is more common after excision of lesions within 2 cm of the dentate line. Ultrasonic dissection is associated with less postoperative haemorrhage than diathermy.

  14. Literature-related discovery techniques applied to ocular disease : a vitreous restoration example

    NARCIS (Netherlands)

    Kostoff, Ronald N.; Los, Leonoor I.

    2013-01-01

    Purpose of reviewLiterature-related discovery and innovation (LRDI) is a text mining approach for bridging unconnected disciplines to hypothesize radical discovery. Application to medical problems involves identifying key disease symptoms, and identifying causes and treatments for those symptoms

  15. Pro-angiogenic TIE-2-expressing monocytes/TEMs as a biomarker of the effect of sorafenib in patients with advanced hepatocellular carcinoma.

    Science.gov (United States)

    Shoji, Hirotaka; Yoshio, Sachiyo; Mano, Yohei; Doi, Hiroyoshi; Sugiyama, Masaya; Osawa, Yosuke; Kimura, Kiminori; Arai, Taeang; Itokawa, Norio; Atsukawa, Masanori; Aoki, Yoshihiko; Fukai, Moto; Taketomi, Akinobu; Mizokami, Masashi; Kanto, Tatsuya

    2017-09-01

    Sorafenib, a multi-kinase inhibitor, inhibits tumor angiogenesis and is the first-line systemic therapy for patients with advanced hepatocellular carcinoma (HCC). However, due to its limited effects and frequent occurrence of side effects, biomarkers are needed to predict the effects of sorafenib. We considered the possibility of using TIE-2-expressing monocytes (TEMs) to predict the response in sorafenib-treated patients with advanced HCC. TEMs serve as a diagnostic marker of HCC and are related to angiogenesis. We analyzed 25 advanced HCC patients and prospectively evaluated TEMs before (Pre TEMs) and at 1 month after initial therapy (T1m TEMs). The radiologic response was evaluated by modified Response Evaluation Criteria in Solid Tumors (mRECIST). Median survival time (MST) was significantly longer in the partial response/stable disease (PR/SD) group (21.8 months) than in the PD group (8.7 months). ΔTEMs (changes of T1m TEMs compared to Pre TEMs) were significantly lower in the PR/SD group than in the PD group. MST of the ΔTEMs low group (14.2 months) was significantly longer than that of the high group (8.7 months). Univariate and multivariate Cox regression analyses showed that ΔTEMs [hazard ratio (HR) = 8.53, 95% confidence interval (CI) = 1.51-48.16, p = 0.015] and Child-Pugh class (HR = 5.59, 95% CI = 1.06-29.63, p = 0.043) were independently associated with overall survival. Our results suggest that ΔTEMs could serve as a biomarker for predicting radiologic response and overall survival in sorafenib-treated patients with advanced HCC. © 2017 UICC.

  16. Evaluation of the reproducibility of two techniques used to determine and record centric relation in angle's class I patients

    Directory of Open Access Journals (Sweden)

    Fernanda Paixão

    2007-08-01

    Full Text Available The centric relation is a mandibular position that determines a balance relation among the temporomandibular joints, the chew muscles and the occlusion. This position makes possible to the dentist to plan and to execute oral rehabilitation respecting the physiological principles of the stomatognathic system. The aim of this study was to investigate the reproducibility of centric relation records obtained using two techniques: Dawson's Bilateral Manipulation and Gysi's Gothic Arch Tracing. Twenty volunteers (14 females and 6 males with no dental loss, presenting occlusal contacts according to those described in Angle's I classification and without signs and symptoms of temporomandibular disorders were selected. All volunteers were submitted five times with a 1-week interval, always in the same schedule, to the Dawson's Bilateral Manipulation and to the Gysi's Gothic Arch Tracing with aid of an intraoral apparatus. The average standard error of each technique was calculated (Bilateral Manipulation 0.94 and Gothic Arch Tracing 0.27. Shapiro-Wilk test was applied and the results allowed application of Student's t-test (sampling error of 5%. The techniques showed different degrees of variability. The Gysi's Gothic Arch Tracing was found to be more accurate than the Bilateral Manipulation in reproducing the centric relation records.

  17. Single injection techniques in determining age-related changes in porcine renal function

    International Nuclear Information System (INIS)

    Robbins, M.E.C.

    1984-01-01

    Glomerular filtration rate (GFR) and effective renal plasma flow (ERPF) were determined in 32 anaesthetised female Large White pigs, aged 4-24 months, from the plasma disappearance curves of [sup(99m)Tc]DTPA and [ 131 I]hippuran respectively. Clearance was also monitored by external counting over the heart. GFR and ERPF increased markedly with age in pigs up to 12 months old, reaching mean values of 242.06 +- 5.89 and 919.39 +- 79.01 mL/min. In pigs aged 12-24 months ERPF increased slightly but renal function remained essentially unchanged after 1 yr of age. These results for renal function were similar to previous estimates, using continuous infusion techniques inferring that GFR and ERPF could be accurately monitored using single injection procedures. (author)

  18. The composition-explicit distillation curve technique: Relating chemical analysis and physical properties of complex fluids.

    Science.gov (United States)

    Bruno, Thomas J; Ott, Lisa S; Lovestead, Tara M; Huber, Marcia L

    2010-04-16

    The analysis of complex fluids such as crude oils, fuels, vegetable oils and mixed waste streams poses significant challenges arising primarily from the multiplicity of components, the different properties of the components (polarity, polarizability, etc.) and matrix properties. We have recently introduced an analytical strategy that simplifies many of these analyses, and provides the added potential of linking compositional information with physical property information. This aspect can be used to facilitate equation of state development for the complex fluids. In addition to chemical characterization, the approach provides the ability to calculate thermodynamic properties for such complex heterogeneous streams. The technique is based on the advanced distillation curve (ADC) metrology, which separates a complex fluid by distillation into fractions that are sampled, and for which thermodynamically consistent temperatures are measured at atmospheric pressure. The collected sample fractions can be analyzed by any method that is appropriate. The analytical methods we have applied include gas chromatography (with flame ionization, mass spectrometric and sulfur chemiluminescence detection), thin layer chromatography, FTIR, corrosivity analysis, neutron activation analysis and cold neutron prompt gamma activation analysis. By far, the most widely used analytical technique we have used with the ADC is gas chromatography. This has enabled us to study finished fuels (gasoline, diesel fuels, aviation fuels, rocket propellants), crude oils (including a crude oil made from swine manure) and waste oils streams (used automotive and transformer oils). In this special issue of the Journal of Chromatography, specifically dedicated to extraction technologies, we describe the essential features of the advanced distillation curve metrology as an analytical strategy for complex fluids. Published by Elsevier B.V.

  19. Muscle Torque and its Relation to Technique, Tactics, Sports Level and Age Group in Judo Contestants

    Science.gov (United States)

    Lech, Grzegorz; Chwała, Wiesław; Ambroży, Tadeusz; Sterkowicz, Stanisław

    2015-01-01

    The aim of this study was to perform a comparative analysis of maximal muscle torques at individual stages of development of athletes and to determine the relationship between muscle torques, fighting methods and the level of sports performance. The activity of 25 judo contestants during judo combats and the effectiveness of actions were evaluated. Maximum muscle torques in flexors/extensors of the body trunk, shoulder, elbow, hip and knee joints were measured. The level of significance was set at p≤0.05; for multiple comparisons the Mann-Whitney U test, p≤0.016, was used. Intergroup differences in relative torques in five muscle groups studied (elbow extensors, shoulder flexors, knee flexors, knee extensors, hip flexors) were not significant. In cadets, relative maximum muscle torques in hip extensors correlated with the activity index (Spearman’s r=0.756). In juniors, maximum relative torques in elbow flexors and knee flexors correlated with the activity index (r=0.73 and r=0.76, respectively). The effectiveness of actions correlated with relative maximum torque in elbow extensors (r=0.67). In seniors, the relative maximum muscle torque in shoulder flexors correlated with the activity index during the second part of the combat (r=0.821). PMID:25964820

  20. Muscle torque and its relation to technique, tactics, sports level and age group in judo contestants.

    Science.gov (United States)

    Lech, Grzegorz; Chwała, Wiesław; Ambroży, Tadeusz; Sterkowicz, Stanisław

    2015-03-29

    The aim of this study was to perform a comparative analysis of maximal muscle torques at individual stages of development of athletes and to determine the relationship between muscle torques, fighting methods and the level of sports performance. The activity of 25 judo contestants during judo combats and the effectiveness of actions were evaluated. Maximum muscle torques in flexors/extensors of the body trunk, shoulder, elbow, hip and knee joints were measured. The level of significance was set at p≤0.05; for multiple comparisons the Mann-Whitney U test, p≤0.016, was used. Intergroup differences in relative torques in five muscle groups studied (elbow extensors, shoulder flexors, knee flexors, knee extensors, hip flexors) were not significant. In cadets, relative maximum muscle torques in hip extensors correlated with the activity index (Spearman's r=0.756). In juniors, maximum relative torques in elbow flexors and knee flexors correlated with the activity index (r=0.73 and r=0.76, respectively). The effectiveness of actions correlated with relative maximum torque in elbow extensors (r=0.67). In seniors, the relative maximum muscle torque in shoulder flexors correlated with the activity index during the second part of the combat (r=0.821).

  1. Integrity evaluation of power plant components by fracture mechanics and related techniques

    International Nuclear Information System (INIS)

    Mukherjee, B.; Vanderglas, M.L.; Davies, P.H.

    1982-01-01

    Power plant components can be subject to unexpected failures with serious consequences, unless careful attention is paid to minute crack defects and their possible growth. The Linear Elastic Fracture Mechanics approach to structural integrity evaluation, as it appears in the ASME Code, is discussed. Projects related to material data generation and the development of structural analysis methods to make the above method usable are described. Several integrity-related questions outside the scope of the Code guidelines are documented, concluding with comments on possible future developments

  2. Using Alternative Teaching Techniques To Enhance Student Performance in the Traditional Introductory Public Relations Course.

    Science.gov (United States)

    Lubbers, Charles A.

    2002-01-01

    Examines the value of two alternative tools as supplements for the traditional introduction to public relations course. Considers the usage of a study manual, usage of televised review sessions, year in school and major status. Indicates that all four variables are significantly correlated with class performance, but that the study manual explains…

  3. Conditioning techniques and ischemic reperfusion injury in relation to on-pump cardiac surgery

    DEFF Research Database (Denmark)

    Holmberg, Fredrik Eric Olof; Ottas, Konstantin Alex; Andreasen, Charlotte

    2014-01-01

    OBJECTIVES: The objective was to investigate the potential protective effects of two conditioning methods, on myocardial ischemic and reperfusion injury in relation to cardiac surgery. DESIGN: Totally 68 patients were randomly assigned to either a control group (n = 23), a remote ischemic...

  4. Short Cuts and Extended Techniques: Rethinking Relations between Technology and Educational Theory

    Science.gov (United States)

    Thumlert, Kurt; de Castell, Suzanne; Jenson, Jennifer

    2015-01-01

    Building upon a recent call to renew actor-network theory (ANT) for educational research, this article reconsiders relations between technology and educational theory. Taking cues from actor-network theorists, this discussion considers the technologically-mediated networks in which learning actors are situated, acted upon, and acting, and traces…

  5. Proceedings of XIV Workshop on Nuclear Physics. VIII International Symposium on Nuclear and Related Techniques. WONP-NURT 2013

    International Nuclear Information System (INIS)

    2013-02-01

    This year 2013, the XIV Workshop on Nuclear Physics and VIII International Symposium on Nuclear and Related Techniques, WONP-NURT 2013 organized by the Center of Technological Applications and Nuclear Development from 5 to 8 February at the National Museum of Fine Arts. NURT is one of the key Cuban scientific meetings since 1997 dealing with the peaceful applications of nuclear techniques in several domains of the society. WONP and NURT provide an unique opportunity for the national and international scientific community to meet outstanding researchers and discuss current trends in several areas of theoretical, experimental and applied nuclear physics and related topics. The papers submitted to this event are presented in this CD-ROM

  6. Proceedings of XV Workshop on Nuclear Physics. IX International Symposium on Nuclear and Related Techniques. WONP-NURT 2015

    International Nuclear Information System (INIS)

    2015-02-01

    This year 2015, the XV Workshop on Nuclear Physics and IX International Symposium on Nuclear and Related Techniques, WONP-NURT 2015 organized by the Center of Technological Applications and Nuclear Development from 9 to 13 February at the National Museum of Fine Arts. NURT is one of the key Cuban scientific meetings since 1997 dealing with the peaceful applications of nuclear techniques in several domains of the society. WONP and NURT provide an unique opportunity for the national and international scientific community to meet outstanding researchers and discuss current trends in several areas of theoretical, experimental and applied nuclear physics and related topics. The papers submitted to this event are presented in this CD-ROM.

  7. Behaviour of TEM metal grids during in-situ heating experiments.

    Science.gov (United States)

    Zhang, Zaoli; Su, Dangsheng

    2009-05-01

    The stability of Ni, Cu, Mo and Au transmission electron microscope (TEM) grids coated with ultra-thin amorphous carbon (alpha-C) or silicon monoxide film is examined by in-situ heating up to a temperature in the range 500-850 degrees C in a transmission electron microscope. It is demonstrated that some grids can generate nano-particles either due to the surface diffusion of metal atoms on amorphous film or due to the metal evaporation/redeposition. The emergence of nano-particles can complicate experimental observations, particularly in in-situ heating studies of dynamic behaviours of nano-materials in TEM. The most widely used Cu grid covered with amorphous carbon is unstable, and numerous Cu nano-particles start to form once the heating temperature reaches 600 degrees C. In the case of Ni grid covered with alpha-C film, a large number of Ni nano-crystals occur immediately when the temperature approaches 600 degrees C, accompanied by the graphitization of amorphous carbon. In contrast, both Mo and Au grids covered with alpha-C film exhibit good stability at elevated temperature, for instance, up to 680 and 850 degrees C for Mo and Au, respectively, and any other metal nano-particles are detected. Cu grid covered Si monoxide thin film is stable up to 550 degrees C, but Si nano-crystals appear under intensive electron beam. The generated nano-particles are well characterized by spectroscopic techniques (EDXS/EELS) and high-resolution TEM. The mechanism of nano-particle formation is addressed based on the interactions between the metal grid and the amorphous carbon film and on the sublimation of metal.

  8. Acupuncture-Related Techniques for Psoriasis: A Systematic Review with Pairwise and Network Meta-Analyses of Randomized Controlled Trials.

    Science.gov (United States)

    Yeh, Mei-Ling; Ko, Shu-Hua; Wang, Mei-Hua; Chi, Ching-Chi; Chung, Yu-Chu

    2017-12-01

    There has be a large body of evidence on the pharmacological treatments for psoriasis, but whether nonpharmacological interventions are effective in managing psoriasis remains largely unclear. This systematic review conducted pairwise and network meta-analyses to determine the effects of acupuncture-related techniques on acupoint stimulation for the treatment of psoriasis and to determine the order of effectiveness of these remedies. This study searched the following databases from inception to March 15, 2016: Medline, PubMed, Cochrane Central Register of Controlled Trials, EBSCO (including Academic Search Premier, American Doctoral Dissertations, and CINAHL), Airiti Library, and China National Knowledge Infrastructure. Randomized controlled trials (RCTs) on the effects of acupuncture-related techniques on acupoint stimulation as intervention for psoriasis were independently reviewed by two researchers. A total of 13 RCTs with 1,060 participants were included. The methodological quality of included studies was not rigorous. Acupoint stimulation, compared with nonacupoint stimulation, had a significant treatment for psoriasis. However, the most common adverse events were thirst and dry mouth. Subgroup analysis was further done to confirm that the short-term treatment effect was superior to that of the long-term effect in treating psoriasis. Network meta-analysis identified acupressure or acupoint catgut embedding, compared with medication, and had a significant effect for improving psoriasis. It was noted that acupressure was the most effective treatment. Acupuncture-related techniques could be considered as an alternative or adjuvant therapy for psoriasis in short term, especially of acupressure and acupoint catgut embedding. This study recommends further well-designed, methodologically rigorous, and more head-to-head randomized trials to explore the effects of acupuncture-related techniques for treating psoriasis.

  9. Techniques for optimizing human-machine information transfer related to real-time interactive display systems

    Science.gov (United States)

    Granaas, Michael M.; Rhea, Donald C.

    1989-01-01

    In recent years the needs of ground-based researcher-analysts to access real-time engineering data in the form of processed information has expanded rapidly. Fortunately, the capacity to deliver that information has also expanded. The development of advanced display systems is essential to the success of a research test activity. Those developed at the National Aeronautics and Space Administration (NASA), Western Aeronautical Test Range (WATR), range from simple alphanumerics to interactive mapping and graphics. These unique display systems are designed not only to meet basic information display requirements of the user, but also to take advantage of techniques for optimizing information display. Future ground-based display systems will rely heavily not only on new technologies, but also on interaction with the human user and the associated productivity with that interaction. The psychological abilities and limitations of the user will become even more important in defining the difference between a usable and a useful display system. This paper reviews the requirements for development of real-time displays; the psychological aspects of design such as the layout, color selection, real-time response rate, and interactivity of displays; and an analysis of some existing WATR displays.

  10. Diagnosis of animal diseases using nuclear and related techniques: Developments and trends

    International Nuclear Information System (INIS)

    Anderson, J.; McKay, J.A.

    1991-01-01

    Nuclear techniques such as radioimmune precipitation, radioimmunoassay, DNA cloning and amino acid sequencing have led to a greater understanding of protein structure and function, antigenic variation and the immune response to infection. Knowledge gained from the use of this technology has led to the development of improved diagnostic assays. Although radioimmunoassay has been used for animal disease diagnosis for many years, more recently it has been replaced by the enzyme linked immunosorbent assay (ELISA). The ELISA offers advantages in speed of reading and longer reagent shelf life and obviates the use of radiochemicals. This is particularly important in developing countries, which may have no facilities for storage, handling and disposal of radioactive materials. In the case of rinderpest diagnosis, taken as an example, the virus neutralization test was replaced by a simple indirect ELISA for seromonitoring throughout the Pan-African Rinderpest Campaign. In the near future, this will be replaced by a competitive ELISA using a rinderpest specific monoclonal antibody, which will offer significant advantages in sensitivity and specificity. In the future it may be possible to replace the rinderpest antigen with vector expressed proteins or synthetic polypeptides. More recent developments such as the 'amplified' ELISA and the use of fluorogenic and bioluminescent substrates may further improve disease diagnosis. The knowledge gained from the use of modern technology is essential to the development of improved diagnostic assays which in turn will lead to improved disease diagnosis and control. (author). 9 refs

  11. Consideration on the diagnostic ability of various imaging techniques in relation to renal tumor

    International Nuclear Information System (INIS)

    Ike, Katsushi

    1984-01-01

    Radiological diagnosis of renal tumors is being improved with the increased imaging accuracy which has resulted from advancement in the various equipment used and improvement in techniques. However, at the clinical level, diagnostic procedures based on the characteristics of the delineated images are not yet established and the diverse diagnostic procedures are being conducted currently in a stereotyped manner. In this study, the images of 61 cases diagnosed as renal tumor were analysed retrospectively with the purpose of establishing the imaging accuracy, capacity for diagnosis based on image characteristics and a subseguent proper diagnostic procedure. It was found that CT and Angio gave similar diagnostic accuracy. It was further revealed that US images enabled to differentiate renal tumors from the more commonly experienced renal cystic disease. For determination of tunica involucrum infiltration, which is essential to diagnose Stage I and II renal tumors, CT was proved to be superior to Angio. CT and US were also to be so in the determination of metastasis to para-aortic lymph nodes which is a Stage III criterion. In recent years, CT and US imaging accuracies have increased, hence the improvement in the capacity to diagnose non-observable renal tumors is highly expected. (author)

  12. Characterization of carbonated serpentine using XPS and TEM

    International Nuclear Information System (INIS)

    Schulze, Roland K.; Hill, Mary Ann; Field, Robert D.; Papin, Pallas A.; Hanrahan, Robert J.; Byler, Darrin D.

    2004-01-01

    With the increasing concentration volume of carbon dioxide in the atmosphere, there has been an increasing interest in carbon dioxide sequestration. One method is to store the carbon dioxide in mineral form, reacting solution dissolved CO 2 to precipitate carbonates. In order to understand whether or not such an endeavor is feasible, the carbonation reaction must first be understood. In this study, the surface of ground serpentine, untreated, heat treated and following a carbonation experiment, has been characterized using X-ray photoelectron spectroscopy (XPS) and transmission electron microscopy (TEM). The results indicate that the mechanism for the reaction involves dissolution of the serpentine through the formation of an amorphous phase and subsequent precipitation of magnesite. The rate limiting step appears to be the diffusion of Mg out of the amorphous phase

  13. TEM examination of irradiated zircaloy-2 pressure tube material

    International Nuclear Information System (INIS)

    Srivastava, D.; Tewari, R.; Dey, G.K.; Sharma, B.P.; Sah, D.N.; Banerjee, Suparna; Sahoo, K.C.

    2005-09-01

    In the present work, microstructure of the zircaloy-2 pressure tube material irradiated in the Indian Pressurized Heavy Water RAPP-1. Reactor (PHWR) has been examined for the first time using transmission electron microscope (TEM). The samples were obtained from a zircaloy-2 pressure tube, which had been in operation in the high flux region of Rajasthan Atomic Power Station Unit -1, for a period for 6.77 effective full power years (EFPYs) and expected to have a cumulative radiation damage of about 3 dpa. In this study irradiated microstructure has been characterized and compared it with the microstructure of the unirradiated pressure tube samples. The effect of irradiation on the hydriding behaviour is also studied. (author)

  14. Water state and TEM analysis of Konjac irradiation copolymer

    International Nuclear Information System (INIS)

    Geng Shengrong; Xia Hezhou; Chen Xueling; Ye Lixiu; Hua Yuejin

    2012-01-01

    To study the absorption performance of Konjac-AA copolymer prepared by irradiation, the water absorbent capacity, sorbent speed and water keeping ability was determined and DSC and TEM analysis were used to explore the water content and structure characters. The results showed that on room temperature the largest water absorption speed was 16 g · g -1 · min -1 at, and the largest water absorption was 400 times at 60 min. The water absorption was affected by granularity, temperature, ion content and ion type, especially the ion type, the water keeping ability was affected by temperature and time, which was up to 35% while the fully water absorbed copolymer was kept under room temperature for 15 d. The free and bounder water content which was assimilated by the plants was 99.617%. The gel stale co polymer has a three-dimensional structure of spiral, which was constituted by spherical objects of varying sizes. (authors)

  15. TEM analysis of fine sulphides dissolution and precipitation in steel

    International Nuclear Information System (INIS)

    Garbarz, B.; Marcisz, J.; Wojtas, J.

    2003-01-01

    Results of transmission electron microscopy (TEM) investigation of morphology, size distribution and chemistry of nano-inclusions formed in 4 mm thick laboratory steel ingots in as-cast condition and after heat treatment are reported. The investigated steel contained 0.11-0.14 C, 0.6 Mn, 0.25 Si, 0.22 Cu, 0.025-0.037 S (wt.%), and 80-115 ppm O and solidified at an average cooling rate of 250 K s -1 . In the as-cast specimens most nano-inclusions had a diameter in the range 10-100 nm with an average size of 30 nm. They were identified by microanalysis in thin foils as sulphides: MnS, (Mn,Cu)S, CuS and Cu 2 S. After a solution treatment of the thin ingots the re-precipitation of nano-sulphides was investigated

  16. Properties of TEM standing waves with E||B

    Science.gov (United States)

    Zaghloul, H.; Buckmaster, H. A.

    This paper summarizes the known properties of E∥B TEM standing waves and shows that for such waves (i) E and B cannot be linearly polarized, (ii) E ≠ αB where α is a constant (iii) it is impossible to find a Lorentz frame where E>B, (iv) direction of the propagation vector cannot be inferred from the fields at one point of the space, (v) their behaviour under Lorentz, parity, time-reversal and gauge transformations is proper, (vi) both Lorentz invariants E2 - B2 and E·B are nonzero, (vii) the magnetic helicity may be nonzero, (viii) the magnetic field may be force-free, and (ix) kμFμv ≠ 0. It also shows how electromagnetic waves can be classified using Lorentz invariants. Cet article résume les qualités connues des ondes stationnaires E∥B TEM et montre que pour des ondes parallèles (i) E et B ne peuvent pas être polarisées linéairement, (ii) E ≠ αB où a est une constante, (iii) il est impossible de trouver une construction de Lorentz où E>B, (iv) la direction de propagation d'un vecteur ne peut pas être déduite des opérations à un point d'intervalle, (v) leur conduite sous Lorentz, parité, temps inverse et transformations de jauge est propre, (vi) les deux invariants de Lorentz E2 - B2 et E·B sont non nulles (vii) l'hélice magnétique peut être non nulle (viii) l'opération magnétique peut être de force libre et (ix) KμFμ v ≠ 0. Ceci montre aussi comment les ondes électromagnétiques peuvent être classifiées, en employant les invariants de Lorentz.

  17. An alternative to the TEM (Transformed Eulerian Mean) equations

    Science.gov (United States)

    Gaßmann, Almut

    2013-04-01

    The TEM equations constitute a powerful means to get access to the residual circulation. However, due to their foundation on the wave perspective, they deliver only a zonally averaged picture without access to the three-dimensional structure or the local origins of the residual circulation. Therefore it is worth to investigate whether there are alternatives. The pathway followed here is to perform a transformation of the momentum and the potential temperature equation before taking the zonal mean. This is done by removing the steady state ideal wind solution vid = ?×?B-(?±P) from the equations (? - potential temperature, B - Bernoulli function, P - Ertel's potential vorticity EPV, ?± - density). The advantage of that approach is that the total EPV-flux does no longer contain an explicitly visible 'do-nothing-flux'. This flux, ?? ×?B, does only vanish when averaging on isentropic surfaces, but not on other isosurfaces. Here we find the reason why the conventional zonal mean on isentropes delivers a direct overturning cell on each hemisphere, whereas on other isosurfaces we obtain the typical three-cell structure with Headley, Ferrel, and polar cells. It will be demonstrated and made visible through idealized climate experiments with the ICON-IAP model that the zonal averages of the nonideal wind components vnid = v - vid and wnid = w - wid constitute similar direct overturning cells on non-isentropic surfaces as obtained with the TEM-generated v* and w*. It is also interesting to inspect fields of local nonideal wind components, the very origin of the residual circulation.

  18. Combined RBS and TEM characterization of nano-SiGe layers embedded in SiO2

    International Nuclear Information System (INIS)

    Kling, A.; Ortiz, M.I.; Sangrador, J.; Rodriguez, A.; Rodriguez, T.; Ballesteros, C.; Soares, J.C.

    2006-01-01

    Grazing incidence RBS has been tested as a technique to detect and characterize SiGe nanoparticles embedded in a SiO 2 matrix. Suitable structures were deposited by low pressure chemical vapour deposition and characterized by TEM and RBS. The layers containing nanoparticles have been modelled by stacks of sublayers consisting of SiGeO layers with compositions calculated according to presumed shapes, sizes, Si/Ge ratios and particle area densities and used as input for RUMP. The nanoparticle parameters obtained by fitting the experimental RBS spectra agree well with the findings by TEM. This demonstrates that RBS is a useful and fast technique to characterize this kind of structures

  19. Use of nuclear and related analytical techniques in environmental research as exemplified by selected air pollution studies

    International Nuclear Information System (INIS)

    Smodis, B.; Jacimovic, R.; Jeran, Z.; Stropnik, B.; Svetina, M.

    2000-01-01

    Among nuclear and nuclear related analytical techniques, neutron activation analysis and X-ray fluorescence spectrometry proved to be particularly useful for environmental studies owing to their nondestructive character and multi element capability. This paper emphasizes their importance among other multielement analytical methods by discussing their specific role due to specific physics basis, quite different to other destructive non-nuclear methods, and by summarizing results obtained in several studies related to air pollution research, including analyses of airborne particulate matter, water samples, lichens and mosses. (author)

  20. Assessment of soil erosion and sedimentation through the use of the 137Cs and related techniques

    International Nuclear Information System (INIS)

    Queralt, I.; Zapata, F.; Garcia Agudo, E.

    2000-01-01

    During the last decades the international scientific community has been increasingly aware of both the risk and the effects of soil erosion and sedimentation processes cause to sustainable agricultural activities and the quality of the superficial environment. Soil erosion is a major environmental worldwide concern of our time. Over the past thirty years two main streams of thought have developed about the effects of soil erosion. The first one, mainly based on ecologist and environmentalist criteria, believes that soil erosion is a true disease on the land that quickly depletes the soil production capacity with some additional subsequent effects such as eutrophication of water reservoirs and pollution of natural waters. The second one supports that soil erosion is a natural process shaping the overall landscape. Development of fertile soils on river valleys can be attributed to erosion processes in the upper reaches of catchment. Loss of productivity due to soil erosion on agricultural lands can be easily compensated by small addition of fertilisers . W h a t ever position we adopt a development of methods offering reliable data is needed. The use of models based on radiogenic isotopes distribution in soil profiles can offer valuable data set both in soil erosion and deposition. In addition, soil redistribution can be effectively assessed. These methods can be applied in a huge range of soil conditions in different geographic zones and the results are comparable at global scale. The International Atomic Energy Agency (IAEA) sponsored since 1995, the implementation of two co-ordinated research projects (CRP's) dealing with the application of the 137 Cs technique in soil erosion and sedimentation studies respectively. A joint Meeting of both CRP's was organised by the Land and Water Conservation Group of the Institute of Earth Sciences 'Jaume Almera', CSIC, in Barcelona, Spain, from 4 to 8 October 1999. This Special Issue of Acta Geologica Hispanica contains a

  1. An evaluation of diabetes targeted apps for Android smartphone in relation to behaviour change techniques.

    Science.gov (United States)

    Hoppe, C D; Cade, J E; Carter, M

    2017-06-01

    Mobile applications (apps) could support diabetes management through dietary, weight and blood glucose self-monitoring, as well as by promoting behaviour change. The present study aimed to evaluate diabetes apps for content, functions and behaviour change techniques (BCTs). Diabetes self-management apps for Android smartphones were searched for on the Google Play Store. Ten apps each from the following search terms were included; 'diabetes', 'diabetes type 1', 'diabetes type 2', 'gestational diabetes'. Apps were evaluated by being scored according to their number of functions and BCTs, price, and user rating. The mean (SD) number of functions was 8.9 (5.9) out of a possible maximum of 27. Furthermore, the mean (SD) number of BCTs was 4.4 (2.6) out of a possible maximum of 26. Apps with optimum BCT had significantly more functions [13.8; 95% confidence interval (CI) = 11.9-15.9] than apps that did not (4.7; 95% CI = 3.2-6.2; P < 0.01) and significantly more BCTs (5.8; 95% CI = 4.8-7.0) than apps without (3.1; 95% CI = 2.2-4.1; P < 0.01). Additionally, apps with optimum BCT also cost more than other apps. In the adjusted models, highly rated apps had an average of 4.8 (95% CI = 0.9-8.7; P = 0.02) more functions than lower rated apps. 'Diabetes apps' include few functions or BCTs compared to the maximum score possible. Apps with optimum BCTs could indicate higher quality. App developers should consider including both specific functions and BCTs in 'diabetes apps' to make them more helpful. More research is needed to understand the components of an effective app for people with diabetes. © 2016 The British Dietetic Association Ltd.

  2. Evidence for the effectiveness of Alexander Technique lessons in medical and health-related conditions: a systematic review.

    Science.gov (United States)

    Woodman, J P; Moore, N R

    2012-01-01

    Complementary medicine and alternative approaches to chronic and intractable health conditions are increasingly being used, and require critical evaluation. The aim of this review was to systematically evaluate available evidence for the effectiveness and safety of instruction in the Alexander Technique in health-related conditions. PUBMED, EMBASE, PSYCHINFO, ISI Web-of-Knowledge, AMED, CINHAL-plus, Cochrane library and Evidence-based Medicine Reviews were searched to July 2011. Inclusion criteria were prospective studies evaluating Alexander Technique instruction (individual lessons or group delivery) as an intervention for any medical indication/health-related condition. Studies were categorised and data extracted on study population, randomisation method, nature of intervention and control, practitioner characteristics, validity and reliability of outcome measures, completeness of follow-up and statistical analyses.   Of 271 publications identified, 18 were selected: three randomised, controlled trials (RCTs), two controlled non-randomised studies, eight non-controlled studies, four qualitative analyses and one health economic analysis. One well-designed, well-conducted RCT demonstrated that, compared with usual GP care, Alexander Technique lessons led to significant long-term reductions in back pain and incapacity caused by chronic back pain. The results were broadly supported by a smaller, earlier RCT in chronic back pain. The third RCT, a small, well-designed, well-conducted study in individuals with Parkinson's disease, showed a sustained increased ability to carry out everyday activities following Alexander lessons, compared with usual care. The 15 non-RCT studies are also reviewed. Strong evidence exists for the effectiveness of Alexander Technique lessons for chronic back pain and moderate evidence in Parkinson's-associated disability. Preliminary evidence suggests that Alexander Technique lessons may lead to improvements in balance skills in the

  3. Applications of decision analysis and related techniques to industrial engineering problems at KSC

    Science.gov (United States)

    Evans, Gerald W.

    1995-01-01

    This report provides: (1) a discussion of the origination of decision analysis problems (well-structured problems) from ill-structured problems; (2) a review of the various methodologies and software packages for decision analysis and related problem areas; (3) a discussion of how the characteristics of a decision analysis problem affect the choice of modeling methodologies, thus providing a guide as to when to choose a particular methodology; and (4) examples of applications of decision analysis to particular problems encountered by the IE Group at KSC. With respect to the specific applications at KSC, particular emphasis is placed on the use of the Demos software package (Lumina Decision Systems, 1993).

  4. Investigation of graphite composite anodes surfaces by atomic force microscopy and related techniques

    Energy Technology Data Exchange (ETDEWEB)

    Hirasawa, Karen Akemi; Nishioka, Keiko; Sato, Tomohiro; Yamaguchi, Shoji; Mori, Shoichiro [Mitsubishi Chemical Corp., Tsukuba Research Center, Ibaraki (Japan)

    1997-11-01

    The surface of a synthetic graphite (KS-44) and polyvinylidene difluoride binder (PVDF) anode for lithium-ion secondary batteries is imaged using atomic force microscopy (AFM) and several related scanning probe microscope (SPM) instruments including: dynamic force microscopy (DFM), friction force microscopy (FFM), laterally-modulated friction force microscopy (LM-FFM), visco-elasticity atomic force microscopy (VE-AFM), and AFM/simultaneous current measurement mode (SCM). DFM is found to be an exceptional mode for topographic imaging while FFM results in the clearest contrast distinction between PVDF binder and KS-44 graphite regions. (orig.)

  5. Comparative study of label and label-free techniques using shotgun proteomics for relative protein quantification.

    Science.gov (United States)

    Sjödin, Marcus O D; Wetterhall, Magnus; Kultima, Kim; Artemenko, Konstantin

    2013-06-01

    The analytical performance of three different strategies, iTRAQ (isobaric tag for relative and absolute quantification), dimethyl labeling (DML) and label free (LF) for relative protein quantification using shotgun proteomics have been evaluated. The methods have been explored using samples containing (i) Bovine proteins in known ratios and (ii) Bovine proteins in known ratios spiked into Escherichia coli. The latter case mimics the actual conditions in a typical biological sample with a few differentially expressed proteins and a bulk of proteins with unchanged ratios. Additionally, the evaluation was performed on both QStar and LTQ-FTICR mass spectrometers. LF LTQ-FTICR was found to have the highest proteome coverage while the highest accuracy based on the artificially regulated proteins was found for DML LTQ-FTICR (54%). A varying linearity (k: 0.55-1.16, r(2): 0.61-0.96) was shown for all methods within selected dynamic ranges. All methods were found to consistently underestimate Bovine protein ratios when matrix proteins were added. However, LF LTQ-FTICR was more tolerant toward a compression effect. A single peptide was demonstrated to be sufficient for a reliable quantification using iTRAQ. A ranking system utilizing several parameters important for quantitative proteomics demonstrated that the overall performance of the five different methods was; DML LTQ-FTICR>iTRAQ QStar>LF LTQ-FTICR>DML QStar>LF QStar. Copyright © 2013 Elsevier B.V. All rights reserved.

  6. In-situ TEM studies of microstructure evolution under ion irradiation for nuclear engineering applications

    International Nuclear Information System (INIS)

    Kaoumi, D.

    2011-01-01

    One of the difficulties of studying processes occurring under irradiation (in a reactor environment) is the lack of kinetics information since usually samples are examined ex situ (i.e. after irradiation) so that only snapshots of the process are available. Given the dynamic nature of the phenomena, direct in situ observation is invaluable for better understanding the mechanisms, kinetics and driving forces of the processes involved. This can be done using in situ ion irradiation in a TEM at the IVEM facility at Argonne National Laboratory which, in the USA, is a unique facility. To predict the in reactor behavior of alloys, it is essential to understand the basic mechanisms of radiation damage formation (loop density, defect interactions) and accumulation (loop evolution, precipitation or dissolution of second phases etc.). In-situ Ion-irradiation in a TEM has proven a very good tool for that purpose as it allows for the direct determination of the formation and evolution of irradiation-induced damage and the spatial correlation of the defect structures with the pre-existing microstructure (including lath boundaries, network dislocations and carbides) as a function of dose, dose rate, temperature and ion type. Using this technique, different aspects of microstructure evolution under irradiation were studied, such as defect cluster formation and evolution as a function of dose in advanced Ferritic/Martensitic (F/M) steels, the irradiation stability of precipitates in Oxide Dispersion Strengthened (ODS) steels, and irradiation-induced grain-growth. Such studies will be reported in this presentation

  7. EBSD and TEM Characterization of High Burn-up Mixed Oxide Fuel

    International Nuclear Information System (INIS)

    Teague, Melissa C; Gorman, Brian P.; Miller, Brandon D; King, Jeffrey

    2014-01-01

    Understanding and studying the irradiation behavior of high burn-up oxide fuel is critical to licensing of future fast breeder reactors. Advancements in experimental techniques and equipment are allowing for new insights into previously irradiated samples. In this work dual column focused ion beam (FIB)/scanning electron microscope (SEM) was utilized to prepared transmission electron microscope samples from mixed oxide fuel with a burn-up of 6.7% FIMA. Utilizing the FIB/SEM for preparation resulted in samples with a dose rate of <0.5 mRem/h compared to approximately 1.1 R/h for a traditionally prepared TEM sample. The TEM analysis showed that the sample taken from the cooler rim region of the fuel pellet had approximately 2.5x higher dislocation density than that of the sample taken from the mid-radius due to the lower irradiation temperature of the rim. The dual column FIB/SEM was additionally used to prepared and serially slice approximately 25 um cubes. High quality electron back scatter diffraction (EBSD) were collected from the face at each step, showing, for the first time, the ability to obtain EBSD data from high activity irradiated fuel

  8. Cross section TEM characterization of high-energy-Xe-irradiated U-Mo

    Energy Technology Data Exchange (ETDEWEB)

    Ye, B., E-mail: bye@anl.gov [Nuclear Engineering Division, Argonne National Laboratory, 9700 S. Cass Ave. Lemont, IL 60439 (United States); Jamison, L.; Miao, Y. [Nuclear Engineering Division, Argonne National Laboratory, 9700 S. Cass Ave. Lemont, IL 60439 (United States); Bhattacharya, S. [Department of Materials Science and Engineering, Northwestern University, 2220 Campus Dr. Evanston, IL 60208 (United States); Hofman, G.L.; Yacout, A.M. [Nuclear Engineering Division, Argonne National Laboratory, 9700 S. Cass Ave. Lemont, IL 60439 (United States)

    2017-05-15

    U-Mo alloys irradiated with 84 MeV Xe ions to various doses were characterized with transmission electron microscopy (TEM) and scanning transmission electron microscopy (STEM) techniques. The TEM thin foils were prepared perpendicular to the irradiated surface to allow a direct observation of the entire region modified by ions. Therefore, depth-selective microstructural information was revealed. Varied irradiation-induced phenomena such as gas bubble formation, phase reversal, and recrystallization were observed at different ion penetration depths in U-Mo. - Highlights: •Three distinct zones were observed along the ion traveling direction in U-7Mo irradiated with 84 MeV Xe ions at 350 °C. •The α-U particles within the Xe-implanted region were reverted to γ-U phase by irradiation. •High-density random intra-granular bubbles in a size of 4–5 nm were found in the irradiated region, coexisting with large inter-granular bubbles. •The high lattice stresses built up during the irradiation-induced phase reversal is probably the driving force for the small grain formation at cell boundaries.

  9. XRD, TEM, and thermal analysis of Arizona Ca-montmorillonites modified with didodecyldimethylammonium bromide.

    Science.gov (United States)

    Sun, Zhiming; Park, Yuri; Zheng, Shuilin; Ayoko, Godwin A; Frost, Ray L

    2013-10-15

    An Arizona SAz-2 calcium montmorillonite was modified by a typical dialkyl cationic surfactant (didodecyldimethylammonium bromide, abbreviated to DDDMA) through direct ion exchange. The obtained organoclays were characterized by X-ray diffraction (XRD), high-resolution transmission electron microscopy (HR-TEM), high-resolution thermogravimetric analysis (HR-TG), and infrared emission spectroscopy (IES). The intercalation of surfactants greatly increased the basal spacing of the interlayers and the conformation arrangement of the loaded surfactant were assessed based on the XRD and TEM measurements. This work shows that the dialkyl surfactant can be directly intercalated into the montmorillonite without first undergoing Na(+) exchange. Moreover, the thermal stability of organoclays and the different arrangements of the surfactant molecules intercalated in the SAz-2 Ca-montmorillonite were determined by a combination of TG and IES techniques. The detailed conformational ordering of different intercalated surfactants under different conditions was also studied. The surfactant molecule DDDMA has proved to be thermally stable even at 400°C which indicates that the prepared organoclay is stable to significantly high temperatures. This study offers new insights into the structure and thermal stabilities of SAz-2 Ca-montmorillonite modified with DDDMA. The experimental results also confirm the potential applications of organic SAz-2 Ca-montmorillonites as adsorbents and polymer-clay nanocomposites. Copyright © 2013 Elsevier Inc. All rights reserved.

  10. eV-TEM: Transmission electron microscopy in a low energy cathode lens instrument

    Energy Technology Data Exchange (ETDEWEB)

    Geelen, Daniël, E-mail: geelen@physics.leidenuniv.nl [Huygens-Kamerlingh Onnes Laboratory, Leiden Institute of Physics, Leiden University, P.O. Box 9504, 2300 RA Leiden (Netherlands); Thete, Aniket [Huygens-Kamerlingh Onnes Laboratory, Leiden Institute of Physics, Leiden University, P.O. Box 9504, 2300 RA Leiden (Netherlands); Schaff, Oliver; Kaiser, Alexander [SPECS GmbH, Voltastrasse 5, D-13355 Berlin (Germany); Molen, Sense Jan van der [Huygens-Kamerlingh Onnes Laboratory, Leiden Institute of Physics, Leiden University, P.O. Box 9504, 2300 RA Leiden (Netherlands); Tromp, Rudolf [IBM T.J. Watson Research Center, 1101 Kitchawan Road, P.O. Box 218, Yorktown Heights, NY 10598 (United States)

    2015-12-15

    We are developing a transmission electron microscope that operates at extremely low electron energies, 0–40 eV. We call this technique eV-TEM. Its feasibility is based on the fact that at very low electron energies the number of energy loss pathways decreases. Hence, the electron inelastic mean free path increases dramatically. eV-TEM will enable us to study elastic and inelastic interactions of electrons with thin samples. With the recent development of aberration correction in cathode lens instruments, a spatial resolution of a few nm appears within range, even for these very low electron energies. Such resolution will be highly relevant to study biological samples such as proteins and cell membranes. The low electron energies minimize adverse effects due to radiation damage. - Highlights: • We present a new way of performing low energy transmission electron microscopy in an aberration corrected LEEM/PEEM instrument. • We show a proof of principle where we measure transmitted electrons through a suspended graphene monolayer with a preliminary setup. • We present an improved setup design that provides better control of the incident electron beam.

  11. Multielement determination in Cuban red mangrove samples using nuclear and related analytical techniques

    International Nuclear Information System (INIS)

    Estevez Alvarez, J.R.; Aguiar Lambert, D.; Montero Alvarez, A.; Pupo Gonzalez, I.; Padilla Alvarez, R.; Gonzalez Garcia, H.; Ramirez Sasco, M.

    1998-01-01

    In the present work the contents of Al; K; Ca; Mn; Fe; Ni; Cu; Zn; Sr; Cd and Pb in red mangroves (Rhizophora mangle) from different Cuban regions are determined, using Energy Dispersive X-Ray Fluorescence (Emission-Transmission (Et) and I/C methods), Atomic Absorption Spectrophotometry (AAS), and Polarography (Anodic Stripping Voltametry method). Biological Certified Reference Materials (CRM) are employed for the tracing of the tracing of the curves of the relative I/C method and for the evaluation of the analytical results accuracy. The reliability of the results is also checked by statistical means. Standard deviations and the detection limits of each method are reported. Finally, the obtained values for the concentration of the different elements in each studied ecosystem are presented; a detailed discussion about their significance will be performed in a further paper

  12. Molecular identification of TEM-116 beta-lactamase gene in isolates ...

    African Journals Online (AJOL)

    Keywords: P. aeruginosa, Clinical isolates, Sequencing, TEM-116, Antibiotic susceptibility. Tropical Journal of ... organisms produce a wide range of beta ... TEM-1 is the most commonly encountered beta-lactamase in Gram-negative bacteria.

  13. Applied research on air pollution using nuclear-related analytical techniques. Report on the second research co-ordination meeting

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-07-01

    A co-ordinated research programme (CRP) on applied research on air pollution using nuclear-related techniques is a global CRP which started in 1992, and is scheduled to run until early 1997. The purpose of this CRP is to promote the use of nuclear analytical techniques in air pollution studies, e.g. NAA, XRF, and PIXE for the analysis of toxic and other trace elements in air particulate matter. The main purposes of the core programme are i) to support the use of nuclear and nuclear-related analytical techniques for research and monitoring studies on air pollution, ii) to identify major sources of air pollution affecting each of the participating countries with particular reference to toxic heavy metals, and iii) to obtain comparative data on pollution levels in areas of high pollution (e.g. a city centre or a populated area downwind of a large pollution source) and low pollution (e.g. rural area). This document reports the discussions held during the second Research Co-ordination Meeting (RCM) for the CRP which took place at ANSTO in Menai, Australia. (author)

  14. Applied research on air pollution using nuclear-related analytical techniques. Report on the second research co-ordination meeting

    International Nuclear Information System (INIS)

    1995-01-01

    A co-ordinated research programme (CRP) on applied research on air pollution using nuclear-related techniques is a global CRP which started in 1992, and is scheduled to run until early 1997. The purpose of this CRP is to promote the use of nuclear analytical techniques in air pollution studies, e.g. NAA, XRF, and PIXE for the analysis of toxic and other trace elements in air particulate matter. The main purposes of the core programme are i) to support the use of nuclear and nuclear-related analytical techniques for research and monitoring studies on air pollution, ii) to identify major sources of air pollution affecting each of the participating countries with particular reference to toxic heavy metals, and iii) to obtain comparative data on pollution levels in areas of high pollution (e.g. a city centre or a populated area downwind of a large pollution source) and low pollution (e.g. rural area). This document reports the discussions held during the second Research Co-ordination Meeting (RCM) for the CRP which took place at ANSTO in Menai, Australia. (author)

  15. A new approach for 3D reconstruction from bright field TEM imaging: Beam precession assisted electron tomography

    International Nuclear Information System (INIS)

    Rebled, J.M.; Yedra, Ll.; Estrade, S.; Portillo, J.; Peiro, F.

    2011-01-01

    The successful combination of electron beam precession and bright field electron tomography for 3D reconstruction is reported. Beam precession is demonstrated to be a powerful technique to reduce the contrast artifacts due to diffraction and curvature in thin foils. Taking advantage of these benefits, Precession assisted electron tomography has been applied to reconstruct the morphology of Sn precipitates embedded in an Al matrix, from a tilt series acquired in a range from +49 o to -61 o at intervals of 2 o and with a precession angle of 0.6 o in bright field mode. The combination of electron tomography and beam precession in conventional TEM mode is proposed as an alternative procedure to obtain 3D reconstructions of nano-objects without a scanning system or a high angle annular dark field detector. -- Highlights: → Electron beam precession reduces spurious diffraction contrast in bright field mode. → Bend contour related contrast depends on precession angle. → Electron beam precession is combined with bright field electron tomography. → Precession assisted BF tomography allowed 3D reconstruction of a Sn precipitate.

  16. Analysis of arsenic speciation in mine contaminated lacustrine sediment using selective sequential extraction, HR-ICPMS and TEM

    International Nuclear Information System (INIS)

    Haus, Kelly L.; Hooper, Robert L.; Strumness, Laura A.; Mahoney, J. Brian

    2008-01-01

    In order to determine how As speciation in lacustrine sediment changes as a function of local conditions, sediment cores were taken from three lakes with differing hydrologic regimes and subjected to extensive chemical and TEM analysis. The lakes (Killarney, Thompson and Swan Lakes) are located within the Coeur d' Alene River system (northern Idaho, USA), which has been contaminated with trace metals and As, from over 100 a of sulfide mining. Previous analyses of these lakebed sediments have shown an extensive amount of contaminant metals and As associated with sub-μm grains, making them extremely difficult to analyze using standard methods (scanning electron microscopy, X-ray diffraction). Transmission electron microscopy offers great advantages in spatial resolution and can be invaluable in determining As speciation when combined with other techniques. Data indicate that because of differences in local redox conditions, As speciation and stability is dramatically different in these lakes. Killarney and Thompson Lakes experience seasonal water-level fluctuations due to drawdown on a downstream dam, causing changes in O 2 content in sediment exposed during drawdown. Swan Lake has relatively constant water levels as its only inlet is dammed. Consequently, Killarney and Thompson Lakes show an increase in labile As-bearing phases with depth, while Swan Lake data indicate stable As hosts throughout the sediment profile. Based on these observations it can be stated that As in lakebed sediments is much less mobile, and therefore less bioavailable, when water is kept at a constant level

  17. A new approach for 3D reconstruction from bright field TEM imaging: Beam precession assisted electron tomography

    Energy Technology Data Exchange (ETDEWEB)

    Rebled, J.M. [LENS-MIND-IN2UB, Departament d' Electronica, Universitat de Barcelona, Marti i Franques 1, 08028 Barcelona (Spain); Institut de Ciencia de Materials de Barcelona-CSIC, Campus UAB, 08193 Bellaterra (Spain); Yedra, Ll. [LENS-MIND-IN2UB, Departament d' Electronica, Universitat de Barcelona, Marti i Franques 1, 08028 Barcelona (Spain); Estrade, S.; Portillo, J. [LENS-MIND-IN2UB, Departament d' Electronica, Universitat de Barcelona, Marti i Franques 1, 08028 Barcelona (Spain); TEM-MAT, CCiT-UB, Sole i Sabaris 1, 08028 Barcelona (Spain); Peiro, F., E-mail: francesca.peiro@ub.edu [LENS-MIND-IN2UB, Departament d' Electronica, Universitat de Barcelona, Marti i Franques 1, 08028 Barcelona (Spain)

    2011-08-15

    The successful combination of electron beam precession and bright field electron tomography for 3D reconstruction is reported. Beam precession is demonstrated to be a powerful technique to reduce the contrast artifacts due to diffraction and curvature in thin foils. Taking advantage of these benefits, Precession assisted electron tomography has been applied to reconstruct the morphology of Sn precipitates embedded in an Al matrix, from a tilt series acquired in a range from +49{sup o} to -61{sup o} at intervals of 2{sup o} and with a precession angle of 0.6{sup o} in bright field mode. The combination of electron tomography and beam precession in conventional TEM mode is proposed as an alternative procedure to obtain 3D reconstructions of nano-objects without a scanning system or a high angle annular dark field detector. -- Highlights: {yields} Electron beam precession reduces spurious diffraction contrast in bright field mode. {yields} Bend contour related contrast depends on precession angle. {yields} Electron beam precession is combined with bright field electron tomography. {yields} Precession assisted BF tomography allowed 3D reconstruction of a Sn precipitate.

  18. Analysis of arsenic speciation in mine contaminated lacustrine sediment using selective sequential extraction, HR-ICPMS and TEM

    Energy Technology Data Exchange (ETDEWEB)

    Haus, Kelly L. [Department of Geology, Phillips 157, University of Wisconsin - Eau Claire, Eau Claire, WI 54702-4004 (United States)], E-mail: khaus@vt.edu; Hooper, Robert L.; Strumness, Laura A.; Mahoney, J. Brian [Department of Geology, Phillips 157, University of Wisconsin - Eau Claire, Eau Claire, WI 54702-4004 (United States)

    2008-04-15

    In order to determine how As speciation in lacustrine sediment changes as a function of local conditions, sediment cores were taken from three lakes with differing hydrologic regimes and subjected to extensive chemical and TEM analysis. The lakes (Killarney, Thompson and Swan Lakes) are located within the Coeur d' Alene River system (northern Idaho, USA), which has been contaminated with trace metals and As, from over 100 a of sulfide mining. Previous analyses of these lakebed sediments have shown an extensive amount of contaminant metals and As associated with sub-{mu}m grains, making them extremely difficult to analyze using standard methods (scanning electron microscopy, X-ray diffraction). Transmission electron microscopy offers great advantages in spatial resolution and can be invaluable in determining As speciation when combined with other techniques. Data indicate that because of differences in local redox conditions, As speciation and stability is dramatically different in these lakes. Killarney and Thompson Lakes experience seasonal water-level fluctuations due to drawdown on a downstream dam, causing changes in O{sub 2} content in sediment exposed during drawdown. Swan Lake has relatively constant water levels as its only inlet is dammed. Consequently, Killarney and Thompson Lakes show an increase in labile As-bearing phases with depth, while Swan Lake data indicate stable As hosts throughout the sediment profile. Based on these observations it can be stated that As in lakebed sediments is much less mobile, and therefore less bioavailable, when water is kept at a constant level.

  19. Study of organohalogens in foodstuffs and environmental samples by neutron activation analysis and related techniques

    International Nuclear Information System (INIS)

    Xu, D. D.; Mao, X.Y.; Ouyang, H.; Chai, Z. F.; Zhang, H.; Sun, H. B.

    2004-01-01

    Pine needles and foodstuffs collected from Beijing, China, were analyzed by instrumental neutron activation analysis (INAA) combined with organic solvent extraction for total halogens, extractable organohalogens (EOX) and extractable persistent organohalogens (EPOX). The INAA detection limits are 50 ng, 8 ng and 3.5 ng for Cl, Br and I, respectively. The contents and distribution patterns of organohalogens in these samples are reported. EOCl accounted for 0.013-0.016% and 1.6-2.7% of the total chlorine in yogurt and apples, respectively, which suggested that chlorine in foodstuffs mainly existed as inorganic species and non-extractable organochlorines. EOCl contents in pine needles and foodstuffs were noticeably higher than those of EOBr and EOI. For pine needles, yogurt and apples, 1.6-34%, 23-58% and 29-35% of EOCl remained as extractable persistent organochlorine (EPOCl), respectively. Pine needle containing higher EOCl contents in chemical industrial and traffic hub areas indicated that chemical industries and exhaust emission from vehicle were the main sources of organochlorines in the Beijing's air. The relative proportions of the known organochlorines (such as HCHs, DDTs, chlordanes, heptachlor, HCB and PCBs) to the total EOCl and EPOCl were 0.04-1.6% and 0.7-21.5%, respectively, which implied that the identity of species of a major portion of the EOCl and EPOCl measured in pine needles was unknown. (author)

  20. Comparative Evaluations and Microstructure: Mechanical Property Relations of Sintered Silicon Carbide Consolidated by Various Techniques

    Science.gov (United States)

    Barick, Prasenjit; Chatterjee, Arya; Majumdar, Bhaskar; Saha, Bhaskar Prasad; Mitra, Rahul

    2018-04-01

    A comparative evaluation between pressureless or self-sintered silicon carbide (SSiC), hot-pressed silicon carbide (HP-SiC), and spark plasma-sintered silicon carbide (SPS-SiC) has been carried out with emphasis on examination of their microstructures and mechanical properties. The effect of sample dimensions on density and properties of SPS-SiC has been also examined. Elastic modulus, flexural strength, and fracture toughness measured by indentation or testing of single-edge notched beam specimens have been found to follow the following trend, HP-SiC > SSiC > SPS-SiC. The SPS-SiC samples have shown size-dependent densification and mechanical properties, with the smaller sample exhibiting superior properties. The mechanical properties of sintered SiC samples appear to be influenced by relative density, grain size, and morphology, as well as the existence of intergranular glassy phase. Studies of fracture surface morphologies have revealed the mechanism of failure to be transgranular in SSiC or HP-SiC, and intergranular in case of SPS-SiC, indicating the dominating influence of grain size and α-SiC formation with high aspect ratio.

  1. Studies of osteoporosis in urban residents of Sao Paulo, Brazil, using isotope related techniques

    International Nuclear Information System (INIS)

    Borelli, Aurelio

    2002-01-01

    Poor bone mass is a major public health problem of worldwide concern. Obviously the main reason for this concern is the fact that the decreasing bone mass is directly related to bone fragility, osteoporosis and increased incidence of fractures affecting mainly elder people. The problems originated from the bone fractures involved areas as economy, social and scientific. Such is the importance of this problem that the Scientific Advisory Committee of the World Health Organization selected osteoporosis as one of the four priority research areas being developed by the Program for Research on Aging. The project on osteoporosis is a crossnational study which will try to explain the differences in hip fractures in countries around the world disclosing the risk and protective factors which will help developing etiologic hypotheses and planning specific preventive interventions. One of the primary objectives is to determine the age range over which peak bone mass (BMD) is maintained which is a valuable guide for plans of osteoporosis prevention. This project is aimed at defining the peak bone mass as well as the period it lasts before the non-nal decrease with aging

  2. Studies of osteoporosis in urban residents of Sao Paulo, Brazil, using isotope related techniques

    International Nuclear Information System (INIS)

    Borelli, A.

    1998-01-01

    Osteoporosis is presently a major problem scientific as well as economic all over the world. For this reason this disease has been studied quite intensely involving not only researchers but also densitometer makers and medicine manufacturers. Many etiologies have been described relating factors which could interfere either in bone formation or bone reabsorption or both. As bone loss along the life is a normal event it is quite understandable that the amount of remaining bone will depend on the amount gained during bone formation. For this reason it is quite important to know the peak of bone mass and the factors that would interfere in the amount of bone formed. It is also very important to define for a certain population its peak of bone mass which would be a valuable guide for future plans of osteoporosis prevention. This project is aimed at defining the peak of bone mass in an urban population which was chosen randomly taken into account the fact that there is a great miscegenation in S.Paulo

  3. A Review of Techniques for Detection of Movement Intention Using Movement-Related Cortical Potentials

    Directory of Open Access Journals (Sweden)

    Aqsa Shakeel

    2015-01-01

    Full Text Available The movement-related cortical potential (MRCP is a low-frequency negative shift in the electroencephalography (EEG recording that takes place about 2 seconds prior to voluntary movement production. MRCP replicates the cortical processes employed in planning and preparation of movement. In this study, we recapitulate the features such as signal’s acquisition, processing, and enhancement and different electrode montages used for EEG data recoding from different studies that used MRCPs to predict the upcoming real or imaginary movement. An authentic identification of human movement intention, accompanying the knowledge of the limb engaged in the performance and its direction of movement, has a potential implication in the control of external devices. This information could be helpful in development of a proficient patient-driven rehabilitation tool based on brain-computer interfaces (BCIs. Such a BCI paradigm with shorter response time appears more natural to the amputees and can also induce plasticity in brain. Along with different training schedules, this can lead to restoration of motor control in stroke patients.

  4. Biomonitoring of air pollution in Jamaica through trace-element analysis of epiphytic plants using nuclear and related analytical techniques

    International Nuclear Information System (INIS)

    Vutchkov, Mitko

    2001-01-01

    The main goal of the Coordinated Research Project (No:9937/R0), entitled 'Biomonitoring of Air Pollution in Jamaica Through Trace-Element Analysis of Epiphytic Plants Using Nuclear and Related Analytical Techniques', is to identify and validate site specific epiphytic plants for biomonitoring the atmospheric pollution in Jamaica using nuclear analytical techniques at the International Centre for Environmental and Nuclear Sciences (ICENS). The specific objectives for the second year of the project were: Development of HOP for sampling epiphytic plants in Jamaica; Sampling design and sample collection; Sample preparation and analysis; Development of an in-house SRM and participation in the NAT-5 inter-laboratory study; Data analysis and interpretation of the results; Development of a work plan of the third year of the project

  5. TEMs but not DKK1 could serve as complementary biomarkers for AFP in diagnosing AFP-negative hepatocellular carcinoma.

    Directory of Open Access Journals (Sweden)

    Liping Mao

    Full Text Available Hepatitis B virus (HBV-related hepatocellular carcinoma (HCC is prevalent worldwide. Despite its limitations, serum alpha-fetoprotein (AFP remains the most widely-used biomarker for the diagnosis of HCC. This study aimed to assess whether measurement of peripheral plasma Dickkopf-1 (DKK1 and Tie2-expressing monocytes (TEMs could overcome the limitations of AFP and improve the diagnostic accuracy of HCC.Plasma DKK1 level and the percentage of TEMs in peripheral CD14+CD16+ monocytes from HCC patients (n = 82, HBV-related liver cirrhosis (LC patients (n = 29, chronic hepatitis B (CHB infected patients (n = 28 and healthy volunteers (n = 31 were analyzed by ELISA and flow cytometry. Receiver operating characteristic (ROC curves were used to analyze a single biomarker, or a combination of two or three biomarkers. Univariate and multivariate analyses were performed to assess the significance of each marker in prediction of HCC and AFP-negative HCC from LC patients.The percentage of TEMs in peripheral CD14+CD16+ monocytes and plasma level of DKK1 in HCC group were significantly higher than those in LC, CHB and healthy control groups (all P-values 0.05. A combination of DKK1, TEMs and AFP measurements increased the AUC for HCC diagnosis as compared with either marker alone (0.833; 95%CI 0.768-0.886. The AUC for TEMs was 0.692 (95% CI 0.564-0.819 in differentiating AFP-negative HCC from LC, with a sensitivity of 80.0% and a specificity of 65.52%. Only TEMs prevailed as a significant predictor for AFP-negative HCC differentiating from LC patients in univariate and multivariate analyses (P = 0.016, P = 0.023.TEMs and DKK1 may prove to be potential complementary biomarkers for AFP in the diagnosis of HCC. TEMs rather than DKK1 could serve as a complementary biomarker for AFP in the differential diagnosis of AFP-negative HCC versus LC patients.

  6. Matrix Results and Techniques in Quantum Information Science and Related Topics

    Science.gov (United States)

    Pelejo, Diane Christine

    In this dissertation, we present several matrix-related problems and results motivated by quantum information theory. Some background material of quantum information science will be discussed in chapter 1, while chapter 7 gives a summary of results and concluding remarks. In chapter 2, we look at 2n x 2 n unitary matrices, which describe operations on a closed n-qubit system. We define a set of simple quantum gates, called controlled single qubit gates, and their associated operational cost. We then present a recurrence scheme to decompose a general 2n x 2n unitary matrix to the product of no more than 2n-12n-1 single qubit gates with small number of controls. In chapter 3, we address the problem of finding a specific element phi among a given set of quantum channels S that will produce the optimal value of a scalar function D(rho 1,phi(rho2)), on two fixed quantum states rho 1 and rho2. Some of the functions we considered for D(·,·) are the trace distance, quantum fidelity and quantum relative entropy. We discuss the optimal solution when S is the set of unitary quantum channels, the set of mixed unitary channels, the set of unital quantum channels, and the set of all quantum channels. In chapter 4, we focus on the spectral properties of qubit-qudit bipartite states with a maximally mixed qudit subsystem. More specifically, given positive numbers a1 ≥ ... ≥ a 2n ≥ 0, we want to determine if there exist a 2n x 2n density matrix rho having eigenvalues a1,..., a2n and satisfying tr 1(rho)=1/n In. This problem is a special case of the more general quantum marginal problem. We give the minimal necessary and sufficient conditions on a1,..., a2n for n ≤ 6 and state some observations on general values of n.. In chapter 5, we discuss the numerical method of alternating projections and illustrate its usefulness in: (a) constructing a quantum channel, if it exists, such that phi(rho(1))=sigma(1),...,phi(rho (k))=sigma(k) for given rho (1),...,rho(k) ∈ Dn and

  7. A P300 event related potential technique for assessment of sexually oriented interest.

    Science.gov (United States)

    Vardi, Yoram; Volos, Michal; Sprecher, Elliot; Granovsky, Yelena; Gruenwald, Ilan; Yarnitsky, David

    2006-12-01

    Despite all of the modern, sophisticated tests that exist for diagnosing and assessing male and female sexual disorders, to our knowledge there is no objective psychophysiological test to evaluate sexual arousal and interest. We provide preliminary data showing a decrease in auditory P300 wave amplitude during exposure to sexually explicit video clips and a significant correlation between the auditory P300 amplitude decrease and self-reported scores of sexual arousal and interest in the clips. A total of 30 healthy subjects were exposed to several blocks of auditory stimuli administered using an oddball paradigm. Baseline auditory P300 amplitudes were obtained and auditory stimuli were then delivered while viewing visual clips with 3 types of content, including sport, scenery and sex. Auditory P300 amplitude significantly decreased during viewing clips of all contents. Viewing sexual content clips caused a maximal decrease in P300 amplitude (p <0.0001). In addition, a high correlation was found between the amplitude decrease and scores on the sexual arousal questionnaire regarding the viewed clips (r = 0.61, p <0.001). In addition, the P300 amplitude decrease was significantly related to the sexual interest score (r = 0.37, p = 0.042) but not to interest in clips of nonsexual content. The change in auditory P300 amplitude during exposure to visual stimuli with sexual context seems to be an objective measure of subject sexual interest. This method might be applied to assess therapeutic intervention and as a diagnostic tool for assessing disorders of impaired libido or psychogenic sexual dysfunction.

  8. IAEA activities in nuclear medicine and related medical applications of nuclear techniques

    International Nuclear Information System (INIS)

    Dudley, R.A.

    1986-01-01

    One of the objectives of the International Atomic Energy Agency, as specified in its Statute, is to ''enlarge the contribution of atomic energy to peace, health and prosperity throughout the world.'' Its programmes in human health include both the exploitation and measurement of radiation fields (radiotherapy and dosimetry) and the use of radionuclides in an investigative or tracer role (the primary subject of this Symposium). The Agency carries out its programmes by means of several mechanisms. The technical co-operation programme, responding to requests for support from governments of Member States, is the dominant mechanism. Through it, experts may be made available to introduce new skills to a laboratory; essential equipment may be provided; and training may be organized in various forms. A second mechanism is the research contract programme, providing financial support to individual laboratories for particular research projects. A third mechanism is information exchange: scientific meetings, publications and the nuclear abstracts service of the International Nuclear Information System (INIS). In the field covered by this Symposium, the technical content of the projects supported by the Agency using these mechanisms may be classed in several categories. One domain that penetrates all others is instrumentation: selection, quality control and maintenance to prevent or correct breakdowns. Another category of activity, requiring the least sophisticated technology, is radioimmunoassay and related procedures. A third category involves the use of radionuclides in vivo, notably the classic applications of nuclear medicine in diagnosing the health status of individual patients, but including also investigation of the nature and aetiology of disease. A fourth category of project includes the study of the biological role of trace elements, especially by neutron activation analysis

  9. Studies of osteoporosis in South Africa using isotope-related and other techniques

    International Nuclear Information System (INIS)

    Wynchank, S.

    1998-01-01

    This report is limited by its being an interim account of the research and is of necessity incomplete. Amongst the present data, there are insufficient results obtained for African subjects and for the extreme age ranges. These lacunae are expected to remain temporary set backs. All the measurements were made on the patients' left sides. This was chosen to coincide with the non-dominant femoral region. One trend is clear for all groups of subjects, where there are sufficient statistics. There is the expected fall in BMD beyond the age of menopause. Although there are severe statistical constraints on data to date from African subjects, their BMD is probably not lower than that of the other groups. Since their social circumstances are generally unsatisfactory, this is at first sight surprising and clearly requires further investigation. For persons of the other two groups the statistics are better. There is little discernible difference in the BMD values of the two groups at all ages. Important questions raised in this work include the following. What are the relative contributions of genetic and dietary influences to differences in BMD? This can only be answered by more BMD studies, especially on Africans, and preferably accompanied by investigations of dietary and other relevant habits It is likely that the African diet differs from that of the other groups. But there is evidence to show that such differences are becoming eroded. (Such evidence arises both from dietary surveys and from incidence of the burden of life-style associated diseases.) Future work will include trace element determinations on autopsy samples

  10. Two novel kinetic techniques for determining relative V/K values for alternate substrates

    International Nuclear Information System (INIS)

    Anderson, V.; Kannan, B.

    1986-01-01

    The equilibrium perturbation method of determining kinetic isotope effects has been extended to permit the accurate measurement of relative V/K values for alternate substrates. In the Enoyl-CoA hydratase reaction at pH 8.0 the V/K for trans-2-pentenoyl-CoA (5:1(2t)-CoA) less than 10% greater than V/K for crotonyl-CoA while at pH 4.6 V/K for 5:1(2t)-CoA is over twice the V/K for crotonyl-CoA. This change in the ratio of V/K values indicates that there must be a pKa in the V/K pH profile for 5:1(2t)-CoA that is not characteristic of the free enzyme, a simple interpretation being 5:1(2t)-CoA is a sticky substrate. The pseudoequilibrium perturbation method is inaccurate when the ratio of V/K values exceeds 3. A companion pseudoequilibrium method is introduced where the initial conditions are constrained to produce an initial velocity of zero, rather than requiring the initial and final concentrations of the chromophoric substrate to be identical. The ratio of V/K values is simply the ratio of the concentration of the perturbant molecule to the equilibrium concentration of the nonperturbing analogue. This method combines the advantages of both the equilibrium perturbation method and of initial steady state measurements. The kinetic mechanism of L-3-hydroxyacyl-CoA dehydrogenase, an enzyme whose severe substrate inhibition and small primary 2 H isotope effect have made routine kinetic studies impractical, has been investigated by this method

  11. Public relations and political support in area-wide integrated pest management programmes that integrate the sterile insect technique

    International Nuclear Information System (INIS)

    Dyck, V.A.; Regidor Fernandez, E.E.; Reyes Flores, J.; Teruya, T.; Barnes, B.; Gomez Riera, P.; Lindquist, D.; Reuben, R.

    2005-01-01

    The public relations component of area-wide integrated pest management (AW-IPM) programmes that integrate the sterile insect technique (SIT) has a large impact on programme success. Full-time professionals should direct public relations activities and secure vital political support from governments and community organizations. Good communication among programme staff, and between programme staff and the public, is required to maintain participation and support, and to keep the work goal-oriented even when some programme activities are controversial. The media can be valuable and effective partners by informing the public about the real facts and activities of a programme, especially if this is done in a non-technical and straightforward way. Ongoing research support improves the programme technology, provides technical credibility on contentious issues, and solves operational problems. Programme failure can result from poor public relations and inadequate public support. (author)

  12. Multi-scale characterization by FIB-SEM/TEM/3DAP.

    Science.gov (United States)

    Ohkubo, T; Sepehri-Amin, H; Sasaki, T T; Hono, K

    2014-11-01

    In order to improve properties of functional materials, it is important to understand the relation between the structure and the properties since the structure has large effect to the properties. This can be done by using multi-scale microstructure analysis from macro-scale to nano and atomic scale. Scanning electron microscope (SEM) equipped with focused ion beam (FIB), transmission electron microscope (TEM) and 3D atom probe (3DAP) are complementary analysis tools making it possible to know the structure and the chemistry from micron to atomic resolution. SEM gives us overall microstructural and chemical information by various kinds of detectors such as secondary electron, backscattered electron, EDS and EBSD detectors. Also, it is possible to analyze 3D structure and chemistry via FIB serial sectioning. In addition, using TEM we can focus on desired region to get more complementary information from HRTEM/STEM/Lorentz images, SAED/NBD patterns and EDS/EELS to see the detail micro or nano-structure and chemistry. Especially, combination of probe Cs corrector and split EDS detectors with large detector size enable us to analyze the atomic scale elemental distribution. Furthermore, if the specimen has a complicated 3D nanostructure, or we need to analyze light elements such as hydrogen, lithium or boron, 3DAP can be used as the only technique which can visualize and analyze distribution of all constituent atoms of our materials within a few hundreds nm area. Hence, site-specific sample preparation using FIB/SEM is necessary to get desired information from region of interest. Therefore, this complementary analysis combination works very well to understand the detail of materials.In this presentation, we will show the analysis results obtained from some of functional materials by Carl Zeiss CrossBeam 1540EsB FIB/SEM, FEI Tecnai G(2) F30, Titan G2 80-200 TEMs and locally build laser assisted 3DAP. As the one of the example, result of multi-scale characterization for

  13. Novel Time-domain Ultra-wide Band TEM Horn Antenna for Highway GPR Applications

    Directory of Open Access Journals (Sweden)

    Yin De

    2017-12-01

    Full Text Available Based on transmission line theory and impedance transition, we design an ultra-wideband Transverse ElectroMagnetic (TEM horn antenna that takes advantage of index gradient structure and loading techniques and is optimized for highway Ground Penetrating Radar (GPR applications. We use numerical simulation to analyze the effects of different curved surfaces as an extension of the antenna and further improve the antenna performance by the use of a metallic reflective cavity and distributed resistor loading. We then fabricated an antenna based on the optimization results and determined the Voltage Standing Wave Ratio (VSWR of the antenna to be less than 2 for bandwidths ranging from 0.9–12.6 GHz. The waveform fidelity of the antenna is also good and when we applied this antenna to highway scenarios, it achieved good results.

  14. TEM and HRTEM of Soot-in-oil particles and agglomerates from internal combustion engines

    International Nuclear Information System (INIS)

    Fay, M W; Rocca, A La; Shayler, P J

    2014-01-01

    Over time, the performance of lubricating oil in a diesel engine is affected by the build-up of carbon soot produced by the combustion process. TEM and HRTEM are commonly used to investigate the characteristics of individual and agglomerated particles from diesel exhaust, to understand the structure and distribution of the carbon sheets in the primary particles and the nanostructure morphology. However, high resolution imaging of soot-in-oil is more challenging, as mineral oil is a contaminant for the electron microscope and leads to instability under the electron beam. In this work we compare solvent extraction and centrifugation techniques for removing the mineral oil contaminant, and the effect on particle size distribution

  15. Intraoperative hypercarbia and massive surgical emphysema secondary to transanal endoscopic microsurgery (TEMS).

    Science.gov (United States)

    Chandra, Aninda; Clarke, Robert; Shawkat, Hany

    2014-03-12

    We describe a case where full-thickness excision of a rectal lesion caused massive surgical emphysema and subsequent hypercarbia with associated difficulties with ventilation. This unique case highlights the risks of respiratory failure with extraperitoneal insufflation as in this case and as more commonly with intraperitoneal insufflation. Transanal endoscopic microsurgery (TEMS) is a technique that is being increasingly used in the management of large and early malignant rectal polyps. We reviewed the literature in order to understand the case and to highlight factors that should minimise any adverse sequelae. In the presence of ventilatory difficulties secondary to postoperative surgical emphysema, whether via extraperitoneal insufflation as described here or with intraperitoneal insufflation (as in laparoscopy), consider decreasing gas pressures, expediting the procedure, delaying extubation and prolonged close monitoring in recovery with possible admission to a high dependency unit (HDU) or intensive care unit (ICU).

  16. TEM investigation of plant-irradiated NPP bolt material

    International Nuclear Information System (INIS)

    Pakarinen, J.; Ehrnsten, U.; Keinaenen, H.; Karlsen, W.; Karlsen, T.

    2015-01-01

    Analytical transmission electron microscopy (ATEM) was used to examine irradiation-induced damage in material removed from two different bolts from two different nuclear power plants. One section came from a French PWR, was made of CW AISI 316, and included a section of the bolt that had accumulated a dose of approximately 15 dpa during 19 operation cycles at 350 - 390 C. degrees. Another section came from a VVER bolt that was removed from the plant due to indications found in non-destructive examinations (NDE). The VVER bolt was made of solution annealed titanium stabilized 0X18H10T (corresponding to Type AISI 321) and had accumulated a fluence of 2.9 dpa. During the removal of that bolt, it was found that the bolt washer had been inappropriately spot welded to the shielding plate during assembly. Destructive investigations showed that the bolt had two large intergranular cracks, and the TEM samples were prepared from the material adjacent to those cracks. The PWR bolt had not failed, although cracks in the bolts with a similar history had been found previously. The fluence for the cold-worked AISI 316 PWR bolt was estimated to be about 15 dpa. Both the examined bolts showed a clear radiation induced segregation of alloying elements at the grain boundaries (GB-RIS), the presence of dislocation loops, the formation of precipitates, and linear deformation microstructures. Additionally, voids were found from the PWR bolt and the VVER bolt had a high density of dislocations. (authors)

  17. TEM study of impurity segregations in beryllium pebbles

    Energy Technology Data Exchange (ETDEWEB)

    Klimenkov, M., E-mail: michael.klimenkov@kit.edu [Institute for Applied Materials – Applied Materials Physics, Karlsruhe Institute of Technology, Hermann-von-Helmholz-Platz 1, 76344 Eggenstein-Leopoldshafen (Germany); Chakin, V.; Moeslang, A. [Institute for Applied Materials – Applied Materials Physics, Karlsruhe Institute of Technology, Hermann-von-Helmholz-Platz 1, 76344 Eggenstein-Leopoldshafen (Germany); Rolli, R. [Institute for Applied Materials – Materials and Biomechanics, Karlsruhe Institute of Technology, Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen (Germany)

    2014-12-15

    Beryllium is planned to be used as a neutron multiplier in the Helium-cooled Pebble Bed European concept of a breeding blanket of demonstration power reactor DEMO. In order to evaluate the irradiation performance, individual pebbles and constrained pebble beds were neutron-irradiated at temperatures typical of fusion blankets. Beryllium pebbles 1 mm in diameter produced by the rotating electrode method were subjected to a TEM study before and after irradiation at High Flux Reactor, Petten, Netherlands at 861 K. The grain size varied in a wide range from sub-micron size up to several tens of micrometers, which indicated formation bimodal grain size distribution. Based on the application of combined electron energy loss spectroscopy and energy dispersive X-ray spectroscopy methods, we suggest that impurity precipitates play an important role in controlling the mechanical properties of beryllium. The impurity elements were present in beryllium at a sub-percent concentration form beryllide particles of a complex (Fe/Al/Mn/Cr)B composition. These particles are often ordered along dislocations lines, forming several micron-long chains. It can be suggested that fracture surfaces often extended along these chains in irradiated material.

  18. Large-scale nanofabrication of periodic nanostructures using nanosphere-related techniques for green technology applications (Conference Presentation)

    Science.gov (United States)

    Yen, Chen-Chung; Wu, Jyun-De; Chien, Yi-Hsin; Wang, Chang-Han; Liu, Chi-Ching; Ku, Chen-Ta; Chen, Yen-Jon; Chou, Meng-Cheng; Chang, Yun-Chorng

    2016-09-01

    Nanotechnology has been developed for decades and many interesting optical properties have been demonstrated. However, the major hurdle for the further development of nanotechnology depends on finding economic ways to fabricate such nanostructures in large-scale. Here, we demonstrate how to achieve low-cost fabrication using nanosphere-related techniques, such as Nanosphere Lithography (NSL) and Nanospherical-Lens Lithography (NLL). NSL is a low-cost nano-fabrication technique that has the ability to fabricate nano-triangle arrays that cover a very large area. NLL is a very similar technique that uses polystyrene nanospheres to focus the incoming ultraviolet light and exposure the underlying photoresist (PR) layer. PR hole arrays form after developing. Metal nanodisk arrays can be fabricated following metal evaporation and lifting-off processes. Nanodisk or nano-ellipse arrays with various sizes and aspect ratios are routinely fabricated in our research group. We also demonstrate we can fabricate more complicated nanostructures, such as nanodisk oligomers, by combining several other key technologies such as angled exposure and deposition, we can modify these methods to obtain various metallic nanostructures. The metallic structures are of high fidelity and in large scale. The metallic nanostructures can be transformed into semiconductor nanostructures and be used in several green technology applications.

  19. Investigation of the load on the lumbar region in nursing technique's movements - relation between twist and surface electromyogram.

    Science.gov (United States)

    Maekawa, Yasuko; Shiozaki, Akira; Majima, Yukie

    2009-01-01

    This study measured the twist angle of the lumbar region and the surface electromyogram (EMG) and examined their mutual relation to elucidate the degree and influence of factors of "twist" in nursing techniques as a cause of lower back pain. Using a goniometer (two-way angle and twist sensors) and an EMG(SX230; DKH Co., Ltd.), we conducted measurements by affixing the goniometer on the lumbar vertebral column and EMG sensor at four points of right and left sides of L2 and L4 (of the erector muscle of the spine). The measured nursing techniques were three common methods of "transferring a patient from bed to wheelchair," which is said to impart a heavy load on the lumbar region. Results show that the correlation value between the twist angle rate and mean energy is likely to be greater, suggesting that the magnitude of the load on the lumbar region should be related to the twist speed rather than to the twist angle of the movement itself.

  20. Oil refinery dusts: morphological and size analysis by TEM.

    Science.gov (United States)

    Sielicki, Przemysław; Janik, Helena; Guzman, Agnieszka; Broniszewski, Mieczysław; Namieśnik, Jacek

    2011-03-01

    The objectives of this work were to develop a means of sampling atmospheric dusts on the premises of an oil refinery for electron microscopic study to carry out preliminary morphological analyses and to compare these dusts with those collected at sites beyond the refinery limits. Carbon and collodion membranes were used as a support for collection of dust particles straight on transmission electron microscopy (TEM) grids. Micrographs of the dust particles were taken at magnifications from ×4,000 to ×80,000 with a Tesla BS500 transmission electron microscope. Four parameters were defined on the basis of the micrographs: surface area, Feret diameter, circumference, and shape coefficient. The micrographs and literature data were used to classify the atmospheric dusts into six groups: particles with an irregular shape and rounded edges; particles with an irregular shape and sharp edges; soot and its aggregates; spherical particles; singly occurring, ultrafine dust particles; and particles not allocated to any of the previous five groups. The types of dusts found in all the samples were similar, although differences did exist between the various morphological parameters. Dust particles with the largest Feret diameter were present in sample 3 (mean, 0.739 μm)-these were collected near the refinery's effluent treatment plant. The particles with the smallest diameter were found in the sample that had been intended to be a reference sample for the remaining results (mean, 0.326 μm). The dust particles collected in the refinery had larger mean Feret diameters, even 100% larger, than those collected beyond it. Particles with diameters from 0.1 to 0.2 μm made up the most numerous group in all the samples collected in the refinery.

  1. Heliborne time-domain electromagnetic (TEM) surveys for uranium exploration

    International Nuclear Information System (INIS)

    Chaturvedi, A.K.

    2015-01-01

    Airborne geophysical surveys have been used extensively in petroleum, mineral exploration, and environmental mapping. Of all the geophysical methods, Electromagnetic (EM) methods, both ground and airborne are used to map the conductive ore bodies buried in the resistive bed rock. Mapping resistivity variations can help unravel complex geological problems and identify areas of hidden potential. Besides the traditional applications to ground water investigations and other natural resource exploration and geological mapping, a number of new applications have been reported. These include hazardous-waste characterization studies, precision agriculture applications, archaeological surveys etc. Airborne Electromagnetic (AEM) methods have undergone rapid improvements over the past few decades. Several new airborne Time Do-main EM (TDEM) systems appeared; existing systems were updated and/or enhanced. The use of natural field (passive) EM surveys continued to increase, with new or improved systems becoming available for both airborne and ground surveys. The number of large airborne survey systems with combined EM, magnetic, gravimetric and gamma-ray spectrometric capabilities also increased. Exploration of a mineral deposit is a multi-stage and multi-disciplinary approach that commences from regional investigations and concludes with establishing of a deposit. As economics play a major role in exploration, a proper integrated study is always beneficial in narrowing down the potential mineral target zones. Heliborne geophysical surveys are being conducted world-wide for exploration of base metals, gold, phosphorite, oil, uranium etc. that are very effective tool in identifying zones of interest accurately, economically and with less span of time. These surveys give a very good insight of surface and sub-surface geophysical signatures that can be attributed to geology with proper modeling. Heliborne Time - domain Electromagnetic (TEM) methods are well known for search of

  2. Oil refinery dusts: morphological and size analysis by TEM

    Energy Technology Data Exchange (ETDEWEB)

    Sielicki, Przemyslaw; Janik, Helena; Guzman, Agnieszka [Gdansk University of Technology, Department of Polymer Technology, Chemical Faculty, Gdansk (Poland); Broniszewski, Mieczyslaw [Environmental Protection Office, Lotos Group, Gdansk (Poland); Namiesnik, Jacek [Gdansk University of Technology, Department of Analytical Chemistry, Chemical Faculty, Gdansk (Poland)

    2011-03-15

    The objectives of this work were to develop a means of sampling atmospheric dusts on the premises of an oil refinery for electron microscopic study to carry out preliminary morphological analyses and to compare these dusts with those collected at sites beyond the refinery limits. Carbon and collodion membranes were used as a support for collection of dust particles straight on transmission electron microscopy (TEM) grids. Micrographs of the dust particles were taken at magnifications from x 4,000 to x 80,000 with a Tesla BS500 transmission electron microscope. Four parameters were defined on the basis of the micrographs: surface area, Feret diameter, circumference, and shape coefficient. The micrographs and literature data were used to classify the atmospheric dusts into six groups: particles with an irregular shape and rounded edges; particles with an irregular shape and sharp edges; soot and its aggregates; spherical particles; singly occurring, ultrafine dust particles; and particles not allocated to any of the previous five groups. The types of dusts found in all the samples were similar, although differences did exist between the various morphological parameters. Dust particles with the largest Feret diameter were present in sample 3 (mean, 0.739 {mu}m) - these were collected near the refinery's effluent treatment plant. The particles with the smallest diameter were found in the sample that had been intended to be a reference sample for the remaining results (mean, 0.326 {mu}m). The dust particles collected in the refinery had larger mean Feret diameters, even 100% larger, than those collected beyond it. Particles with diameters from 0.1 to 0.2 {mu}m made up the most numerous group in all the samples collected in the refinery. (orig.)

  3. Quantitative in-situ TEM nanotensile testing of single crystal Ni facilitated by a new sample preparation approach.

    Science.gov (United States)

    Samaeeaghmiyoni, Vahid; Idrissi, Hosni; Groten, Jonas; Schwaiger, Ruth; Schryvers, Dominique

    2017-03-01

    Twin-jet electro-polishing and Focused Ion Beam (FIB) were combined to produce small size Nickel single crystal specimens for quantitative in-situ nanotensile experiments in the transmission electron microscope. The combination of these techniques allows producing samples with nearly defect-free zones in the centre in contrast to conventional FIB-prepared samples. Since TEM investigations can be performed on the electro-polished samples prior to in-situ TEM straining, specimens with desired crystallographic orientation and initial microstructure can be prepared. The present results reveal a dislocation nucleation-controlled plasticity, in which small loops induced by FIB near the edges of the samples play a central role. Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. Analyzing the scale of the bainitic ferrite plates by XRD, SEM and TEM

    International Nuclear Information System (INIS)

    Garcia-Mateo, Carlos; Jimenez, Jose A.; Lopez-Ezquerra, Belen; Rementeria, Rosalia; Morales-Rivas, Lucia; Kuntz, Matthias; Caballero, Francisca G.

    2016-01-01

    Since the major strengthening mechanisms in nanocrystalline bainitic steels arise from the exceptionally small size of the bainitc ferrite plate, accurate determination of this parameter is fundamental for quantitative relating the microstructure to the mechanical properties. In this work, the thickness of the bainitic ferrite subunits obtained by different bainitic heat treatments was determined in two steels, with carbon contents of 0.3 and 0.7 wt.%, from SEM and TEM micrographs. As these measurements were made on 2D images taken from random sections, the method includes some stereological correction factors to obtain accurate information. Finally, the determined thicknesses of bainitic ferrite plates were compared with the crystallite size calculated from the analysis of X-ray diffraction peak broadening. Although in some case the values obtained for crystallite size and plate thickness can be similar, this study confirms that indeed they are two different parameters. - Highlights: •Bainitic microstructure in a nanostructured and sub-micron steel •Bainitic ferrite plate thickness measured by SEM and TEM •Crystallite size determined by X-ray analysis

  5. Analyzing the scale of the bainitic ferrite plates by XRD, SEM and TEM

    Energy Technology Data Exchange (ETDEWEB)

    Garcia-Mateo, Carlos, E-mail: cgm@cenim.csic.es [Department of Physical Metallurgy, Spanish National Center for Metallurgical Research (CENIM-CSIC), Avda. Gregorio del Amo 8, E-28040 Madrid (Spain); Jimenez, Jose A.; Lopez-Ezquerra, Belen; Rementeria, Rosalia; Morales-Rivas, Lucia [Department of Physical Metallurgy, Spanish National Center for Metallurgical Research (CENIM-CSIC), Avda. Gregorio del Amo 8, E-28040 Madrid (Spain); Kuntz, Matthias [Robert-Bosch GmbH, Materials and Process Engineering Metals, Renningen, 70465 Stuttgart (Germany); Caballero, Francisca G. [Department of Physical Metallurgy, Spanish National Center for Metallurgical Research (CENIM-CSIC), Avda. Gregorio del Amo 8, E-28040 Madrid (Spain)

    2016-12-15

    Since the major strengthening mechanisms in nanocrystalline bainitic steels arise from the exceptionally small size of the bainitc ferrite plate, accurate determination of this parameter is fundamental for quantitative relating the microstructure to the mechanical properties. In this work, the thickness of the bainitic ferrite subunits obtained by different bainitic heat treatments was determined in two steels, with carbon contents of 0.3 and 0.7 wt.%, from SEM and TEM micrographs. As these measurements were made on 2D images taken from random sections, the method includes some stereological correction factors to obtain accurate information. Finally, the determined thicknesses of bainitic ferrite plates were compared with the crystallite size calculated from the analysis of X-ray diffraction peak broadening. Although in some case the values obtained for crystallite size and plate thickness can be similar, this study confirms that indeed they are two different parameters. - Highlights: •Bainitic microstructure in a nanostructured and sub-micron steel •Bainitic ferrite plate thickness measured by SEM and TEM •Crystallite size determined by X-ray analysis.

  6. Determination of the activation energy in a cast aluminium alloy by TEM and DSC

    International Nuclear Information System (INIS)

    Ovono Ovono, D.; Guillot, I.; Massinon, D.

    2007-01-01

    The precipitation behaviour and microstructure development of the A319 alloy during ageing were investigated by scanning electron microscopy (SEM), transmission electron microscopy (TEM and STEM). During T5 treatment, θ' precipitates with an average size of about 18 nm were observed by TEM. The precipitate sizes increased with ageing temperature and attained an average size of 107 nm. In addition, there was a linear relationship between precipitate growth temperature and the cube of the precipitate size. This indicates that precipitate growth of the A319 alloy belongs to a thermal activated process of the Arrhenius type. The activation energy for the precipitate growth was calculated to be 140.4 ± 13.3 kJ/mol. However, under continuous heating conditions, the activation energy for the precipitate growth obtained by Kissinger plot was determined to be 119.5 ± 8.3 kJ/mol. Allowing for experimental error, both values are comparable and are related to the diffusion of Cu and/or Si in Al

  7. TEM characterization of corrosion products formed on a SS-15ZR alloy

    International Nuclear Information System (INIS)

    Luo, J. S.; Abraham, D. P.

    2000-01-01

    The corrosion products formed on a stainless steel-15Zr (SS-15Zr) alloy have been characterized by transmission electron microscopy (TEM) and energy dispersive x-ray spectroscopy (EDS). Examination of alloy particles that were immersed in 90 C deionized water for two years revealed that different corrosion products were formed on the stainless steel and intermetallic phases. Two corrosion products were identified on an austenite particle: trevorite (NiFe 2 O 4 ) in the layer close to the metal and maghemite (Fe 2 O 3 ) in the outer layer. The corrosion layer formed on the intermetallic was uniform, adherent, and amorphous. The EDS analysis indicated that the layer was enriched in zirconium when compared with the intermetallic composition. High-resolution TEM images of the intermetallic-corrosion layer interface show an interlocking metal-oxide interface which may explain the relatively strong adherence of the corrosion layer to the intermetallic surface. These results will be used to evaluate corrosion mechanisms and predict long-term corrosion behavior of the alloy waste form

  8. Towards 3D crystal orientation reconstruction using automated crystal orientation mapping transmission electron microscopy (ACOM-TEM).

    Science.gov (United States)

    Kobler, Aaron; Kübel, Christian

    2018-01-01

    To relate the internal structure of a volume (crystallite and phase boundaries) to properties (electrical, magnetic, mechanical, thermal), a full 3D reconstruction in combination with in situ testing is desirable. In situ testing allows the crystallographic changes in a material to be followed by tracking and comparing the individual crystals and phases. Standard transmission electron microscopy (TEM) delivers a projection image through the 3D volume of an electron-transparent TEM sample lamella. Only with the help of a dedicated TEM tomography sample holder is an accurate 3D reconstruction of the TEM lamella currently possible. 2D crystal orientation mapping has become a standard method for crystal orientation and phase determination while 3D crystal orientation mapping have been reported only a few times. The combination of in situ testing with 3D crystal orientation mapping remains a challenge in terms of stability and accuracy. Here, we outline a method to 3D reconstruct the crystal orientation from a superimposed diffraction pattern of overlapping crystals without sample tilt. Avoiding the typically required tilt series for 3D reconstruction enables not only faster in situ tests but also opens the possibility for more stable and more accurate in situ mechanical testing. The approach laid out here should serve as an inspiration for further research and does not make a claim to be complete.

  9. Speciation of trace elements in biological samples by nuclear analytical and related techniques coupled with chemical and biochemical separation

    International Nuclear Information System (INIS)

    Chen, C.Y.; Gao, Y.X.; Li, B.; Yu, H.W.; Li, Y.F.; Sun, J.; Chai, Z.F.

    2005-01-01

    In the past, most analytical problems relating to biological systems were addressed by measuring the total concentrations of elements. Now there is increasing interest of the importance of their chemical forms, in which an element is present in biological systems, e.g., the oxidation state, the binding state with macromolecules, or even the molecular structure. The biological effects of chromium, which is classified as an essential nutrient, are dependent upon its oxidation. state. In general, trivalent chromium is biochemically active, whereas hexavalent chromium is considered to be toxic. Mercury is one of serious environmental persistent pollutants. However, organic forms of mercury are known to possess much higher toxicity than inorganic mercury. Therefore, information on speciation is critically required in order to better understanding of their bioavailability, metabolism, transformation, and toxicity in vivo. Recently, chemical speciation of selenium, mercury, copper, zinc, iron, and so on, has been investigated by INAA, ICP-MS, XRF, EXAFS and related techniques combined with chemical and biochemical separation (extraction, chromatography, gel electrophoresis, etc.). INAA, XRF, and ICP-MS have superior advantages in aspect of multielemental analysis with high accuracy and sensitivity, which render the possibility of analyzing various elements of interest simultaneously. These offline or online techniques have been flexibly applied to different biological matrixes, such as human hair, serum, urine, various tissues and organs in our researches. In addition, EXAFS provides structural information about the moiety of metal centers up to a distance of approximately 4-5 Anstrom. For instance, hepatocellular carcinoma (HCC) is one of the most common cancers worldwide. Imbalance of elements, such as Se, Zn, Fe, Cu, Cd, Ca, etc., has been found in the whole blood or serum of patients with HCC. We found that the profiles of Se, Cd, Fe, Zn and Cu-containing proteins

  10. The investigation of nanostructures of magnetic recording media by TEM

    International Nuclear Information System (INIS)

    Peng Yingguo; Ohkubo, Tadakatsu; Laughlin, David E.

    2003-01-01

    Diverse applications of transmission electron microscopy techniques used in investigating the nanostructures of magnetic recording materials are presented. Specimen preparation methods are discussed for the specific case of magnetic thin film recording media. Investigations of the crystallographic orientation, grain size and distribution, and interfacial nanostructures are presented

  11. Oxidation of nickel particles in an environmental TEM

    DEFF Research Database (Denmark)

    Jeangros, Q.; Hansen, Thomas Willum; Wagner, Jakob Birkedal

    nanometres in size. These domains impinge and cover the particles surface. As the temperature increases under O2, the NiO film grows and creates irregular structures composed of many crystallites. The reaction kinetics are inferred by EELS using different techniques analyzing changes in shapes of the Ni L2...... temperature, providing new insights into oxidation/corrosion processes....

  12. A TEM Study on the Microstructure of Fine Flaky Graphite

    DEFF Research Database (Denmark)

    Moumeni, Elham; Tiedje, Niels Skat; Horsewell, Andy

    In this investigation the microstructure of the graphite flakes in titanium alloyed cast iron is studied using electron microscopy techniques. Based on this information, growth models for the platelets in the fine graphite flakes in cast iron are considered. Detailed crystallographic analysis...... of the defects observed such as multiple twin boundaries and possible spiral growth configurations are required...

  13. Progress in study of Prespa Lake using nuclear and related techniques (IAEA Regional Project RER/8/008)

    International Nuclear Information System (INIS)

    Anovski, Todor

    2001-09-01

    One of the main objective of the IAEA - Regional project RER/8/008 entitled Study of Prespa Lake Using Nuclear and Related Techniques was to provide a scientific basis for sustainable and environmental management of the Lake Prespa (Three lakes: Ohrid, Big Prespa and Small Prespa are on the borders between Albania, Republic of Macedonia and Greece, and are separated by the Mali i Thate and Galichica, mostly Carstificated mountains), see Fig. 1. In this sense investigations connected with the hydrogeology, water quality (Physics-chemical, biological and radiological characteristics) and water balance determination by application of Environmental isotopes ( i.e. H,D,T,O-18,O-18 etc.,) distribution, artificial water tracers and other relevant analytical techniques such as: AAS, HPLC, Total α and β-activity, α and γ-spectrometry as well as ultra sonic measurements (defining of the Lake bottom profile) through regional cooperation / Scientists from Albania, Greece and Republic of Macedonia, participated in the implementation of the Project/ during one hydrological year, had been initiated and valuable results obtained, a part of which are presented in this report. This cooperation was the only way for providing necessary data for better understanding beside the other, of the water quality of the Prespa Lake and its hydrological relationship to Ohrid Lake too, representing a unique regional hydro system in the world. (Author)

  14. Theory and practical understanding of the migration behavior of proteins and peptides in CE and related techniques.

    Science.gov (United States)

    Freitag, Ruth; Hilbrig, Frank

    2007-07-01

    CEC is defined as an analytical method, where the analytes are separated on a chromatographic column in the presence of an applied voltage. The separation of charged analytes in CEC is complex, since chromatographic interaction, electroosmosis and electrophoresis contribute to the experimentally observed behavior. The putative contribution of effects such as surface electrodiffusion has been suggested. A sound theoretical treatment incorporating all effects is currently not available. The question of whether the different effects contribute in an independent or an interdependent manner is still under discussion. In this contribution, the state-of-the-art in the theoretical description of the individual contributions as well as models for the retention behavior and in particular possible dimensionless 'retention factors' is discussed, together with the experimental database for the separation of charged analytes, in particular proteins and peptides, by CEC and related techniques.

  15. Characterization of TEM1/endosialin in human and murine brain tumors

    International Nuclear Information System (INIS)

    Carson-Walter, Eleanor B; Walter, Kevin A; Winans, Bethany N; Whiteman, Melissa C; Liu, Yang; Jarvela, Sally; Haapasalo, Hannu; Tyler, Betty M; Huso, David L; Johnson, Mahlon D

    2009-01-01

    TEM1/endosialin is an emerging microvascular marker of tumor angiogenesis. We characterized the expression pattern of TEM1/endosialin in astrocytic and metastatic brain tumors and investigated its role as a therapeutic target in human endothelial cells and mouse xenograft models. In situ hybridization (ISH), immunohistochemistry (IH) and immunofluorescence (IF) were used to localize TEM1/endosialin expression in grade II-IV astrocytomas and metastatic brain tumors on tissue microarrays. Changes in TEM1/endosialin expression in response to pro-angiogenic conditions were assessed in human endothelial cells grown in vitro. Intracranial U87MG glioblastoma (GBM) xenografts were analyzed in nude TEM1/endosialin knockout (KO) and wildtype (WT) mice. TEM1/endosialin was upregulated in primary and metastatic human brain tumors, where it localized primarily to the tumor vasculature and a subset of tumor stromal cells. Analysis of 275 arrayed grade II-IV astrocytomas demonstrated TEM1/endosialin expression in 79% of tumors. Robust TEM1/endosialin expression occurred in 31% of glioblastomas (grade IV astroctyomas). TEM1/endosialin expression was inversely correlated with patient age. TEM1/endosialin showed limited co-localization with CD31, αSMA and fibronectin in clinical specimens. In vitro, TEM1/endosialin was upregulated in human endothelial cells cultured in matrigel. Vascular Tem1/endosialin was induced in intracranial U87MG GBM xenografts grown in mice. Tem1/endosialin KO vs WT mice demonstrated equivalent survival and tumor growth when implanted with intracranial GBM xenografts, although Tem1/endosialin KO tumors were significantly more vascular than the WT counterparts. TEM1/endosialin was induced in the vasculature of high-grade brain tumors where its expression was inversely correlated with patient age. Although lack of TEM1/endosialin did not suppress growth of intracranial GBM xenografts, it did increase tumor vascularity. The cellular localization of TEM1

  16. Transmission Electron Microscopy (TEM) Sample Preparation of Si(1-x)Gex in c-Plane Sapphire Substrate

    Science.gov (United States)

    Kim, Hyun Jung; Choi, Sang H.; Bae, Hyung-Bin; Lee, Tae Woo

    2012-01-01

    The National Aeronautics and Space Administration-invented X-ray diffraction (XRD) methods, including the total defect density measurement method and the spatial wafer mapping method, have confirmed super hetero epitaxy growth for rhombohedral single crystalline silicon germanium (Si1-xGex) on a c-plane sapphire substrate. However, the XRD method cannot observe the surface morphology or roughness because of the method s limited resolution. Therefore the authors used transmission electron microscopy (TEM) with samples prepared in two ways, the focused ion beam (FIB) method and the tripod method to study the structure between Si1-xGex and sapphire substrate and Si1?xGex itself. The sample preparation for TEM should be as fast as possible so that the sample should contain few or no artifacts induced by the preparation. The standard sample preparation method of mechanical polishing often requires a relatively long ion milling time (several hours), which increases the probability of inducing defects into the sample. The TEM sampling of the Si1-xGex on sapphire is also difficult because of the sapphire s high hardness and mechanical instability. The FIB method and the tripod method eliminate both problems when performing a cross-section TEM sampling of Si1-xGex on c-plane sapphire, which shows the surface morphology, the interface between film and substrate, and the crystal structure of the film. This paper explains the FIB sampling method and the tripod sampling method, and why sampling Si1-xGex, on a sapphire substrate with TEM, is necessary.

  17. SEM and TEM characterization of microstructure of stainless steel composites reinforced with TiB2

    International Nuclear Information System (INIS)

    Sulima, Iwona; Boczkal, Sonia; Jaworska, Lucyna

    2016-01-01

    Steel-8TiB 2 composites were produced by two new sintering techniques, i.e. Spark Plasma Sintering (SPS) and High Pressure-High Temperature (HP-HT) sintering. This study discusses the impact of these sintering methods on the microstructure of steel composites reinforced with TiB 2 particles. Scanning electron microscopy (SEM), wavelength dispersive spectroscopy (WDS), X-ray diffraction, electron backscatter diffraction (EBSD) and transmission electron microscopy (TEM) were used to analyze the microstructure evolution in steel matrix composites. The results of microscopic examinations revealed a close relationship between the composite microstructure and the methods and conditions of sintering. Substantial differences were observed in the grain size of materials sintered by HP-HT and SPS. It has been demonstrated that the composites sintered by HP-HT tend to form a chromium-iron-nickel phase in the steel matrix. In contrast, the microstructure of the composites sintered by SPS is characterized by the presence of complex borides and chromium-iron phase. - Highlights: •The steel-8TiB 2 composites were fabricated by Spark Plasma Sintering (SPS) and High Pressure-High Temperature (HP-HT). •Sintering techniques has an important effect on changes in the microstructure of steel-8TiB 2 composites. •New phases of different size and morphology were identified.

  18. TEM study of amorphous alloys produced by ion implantation

    International Nuclear Information System (INIS)

    Johnson, E.; Grant, W.A.; Wohlenberg, P.; Hansen, P.; Chadderton, L.T.

    1978-01-01

    Ion implantation is a technique for introducing foreign elements into surface layers of solids. Ions, as a suitably accelerated beam, penetrate the surface, slow down by collisions with target atoms to produce a doped layer. This non-equilibrium technique can provide a wide range of alloys without the restrictions imposed by equilibrium phase diagrams. This paper reports on the production of some amorphous transition metal-metalloid alloys by implantation. Thinned foils of Ni, Fe and stainless steel were implanted at room temperature with Dy + and P + ions at doses between 10 13 - 10 17 ions/cm 2 at energies of 20 and 40 keV respectively. Transmission electron microscopy and selected area diffraction analysis were used to investigate the implanted specimens. Radial diffracted intensity measurements confirmed the presence of an amorphous implanted layer. The peak positions of the maxima are in good agreement with data for similar alloys produced by conventional techniques. Only certain ion/target combinations produce these amorphous layers. Implantations at doses lower than those needed for amorphization often result in formation of new crystalline phases such as an h.c.p. phase in nickel and a b.c.c. phase in stainless steel. (Auth.)

  19. Mechanical properties and TEM examination of RAFM steels irradiated up to 70 dpa in BOR-60

    Energy Technology Data Exchange (ETDEWEB)

    Gaganidze, E., E-mail: Ermile.Gaganidze@kit.edu [Karlsruher Institut fuer Technologie, Institut fuer Angewandte Materialien, Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen (Germany); Petersen, C.; Materna-Morris, E.; Dethloff, C.; Weiss, O.J.; Aktaa, J. [Karlsruher Institut fuer Technologie, Institut fuer Angewandte Materialien, Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen (Germany); Povstyanko, A.; Fedoseev, A.; Makarov, O.; Prokhorov, V. [Joint Stock Company ' State Scientific Centre Research Institute of Atomic Reactors' , 433510 Dimitrovgrad-10, Ulyanovsk Region (Russian Federation)

    2011-10-01

    Mechanical properties of Reduced Activation Ferritic/Martensitic (RAFM) steels were studied after irradiation in BOR-60 reactor to a neutron displacement damage of 70 dpa at 330-340 deg. C. Yield stress and Ductile-to-Brittle-Transition-Temperature of EUROFER97 indicate saturation of hardening and embrittlement. The phenomenological models for description of microstructure evolution and resulting irradiation hardening and embrittlement are discussed. The evolution of yield stress with dose is qualitatively understood within a Whapham and Makin model. Dislocation loops examined in TEM are considered a main source for low-temperature irradiation hardening. The analysis of the fatigue data in terms of the inelastic strain reveals comparable fatigue behaviour both for unirradiated and irradiated conditions, which can be described by a common Manson-Coffin relation. The study of helium effects in B-doped model steels indicated progressive material embrittlement with helium content. Post-irradiation annealing of RAFM steels yielded substantial recovery of mechanical properties.

  20. OSCE vs. TEM: Different approaches to assess clinical skills of nursing students

    Directory of Open Access Journals (Sweden)

    Prasuna Jelly

    2017-01-01

    Full Text Available Introduction: Nurses are trained with specific clinical skills, and objective structured clinical examination (OSCE could be a better approach to assess clinical skills of nursing students. Materials and Methods: A comparative study was conducted by observational checklist regarding antenatal care and opinionnaire on the usefulness of OSCE and tradition evaluation method (TEM was used to assess the clinical skills and to get opinion. Results: The mean score of OSCE was more than TEM and the difference was statistically significant (P < 0.001. The opinion of students regarding the usefulness of OSCE was higher than TEM. Conclusions: The study concluded that implementing OSCE will overweigh the advantages of the TEM.

  1. Retrofit implementation of Zernike phase plate imaging for cryo-TEM.

    Science.gov (United States)

    Marko, Michael; Leith, Ardean; Hsieh, Chyongere; Danev, Radostin

    2011-05-01

    In-focus phase-plate imaging is particularly beneficial for cryo-TEM because it offers a substantial overall increase in image contrast, without an electron dose penalty, and it simplifies image interpretation. We show how phase-plate cryo-TEM can be implemented with an appropriate existing TEM, and provide a basic practical introduction to use of thin-film (carbon) phase plates. We point out potential pitfalls of phase-plate operation, and discuss solutions. We provide information on evaluating a particular TEM for its suitability. Copyright © 2011 Elsevier Inc. All rights reserved.

  2. A simple algorithm for measuring particle size distributions on an uneven background from TEM images

    DEFF Research Database (Denmark)

    Gontard, Lionel Cervera; Ozkaya, Dogan; Dunin-Borkowski, Rafal E.

    2011-01-01

    Nanoparticles have a wide range of applications in science and technology. Their sizes are often measured using transmission electron microscopy (TEM) or X-ray diffraction. Here, we describe a simple computer algorithm for measuring particle size distributions from TEM images in the presence of a...... application to images of heterogeneous catalysts is presented.......Nanoparticles have a wide range of applications in science and technology. Their sizes are often measured using transmission electron microscopy (TEM) or X-ray diffraction. Here, we describe a simple computer algorithm for measuring particle size distributions from TEM images in the presence...

  3. Investigation of diversity of plasmids carrying the blaTEM-52 gene

    DEFF Research Database (Denmark)

    Bielak, Eliza Maria; Bergenholtz, Rikke D.; Jørgensen, Mikael Skaanning

    2011-01-01

    OBJECTIVES: To investigate the diversity of plasmids that carry blaTEM-52 genes among Escherichia coli and Salmonella enterica originating from animals, meat products and humans. METHODS: A collection of 22 blaTEM-52-encoding plasmids was characterized by restriction fragment length polymorphism...... of self-transfer to a plasmid-free E. coli recipient. CONCLUSIONS: The blaTEM-52 gene found in humans could have been transmitted on transferable plasmids originating from animal sources. Some of the blaTEM-52 plasmids carry replicons that differ from the classical ones. Two novel replicons were detected...

  4. Fast FIB-milled Electron-transparent Microchips for in situ TEM Investigations

    DEFF Research Database (Denmark)

    Lei, Anders; Petersen, Dirch Hjorth; Kallesøe, Christian

    In this work we present a fast approach to 50 nm resolution structures defined in a generic TEM-chip template in few minutes. While creating complex electrical and NEMS circuits for a specific insitu TEM experiment can be a cumbersome process, microchips with 100 nm thin flakes of single crystall......In this work we present a fast approach to 50 nm resolution structures defined in a generic TEM-chip template in few minutes. While creating complex electrical and NEMS circuits for a specific insitu TEM experiment can be a cumbersome process, microchips with 100 nm thin flakes of single...

  5. Identification of proangiogenic TIE2-expressing monocytes (TEMs) in human peripheral blood and cancer.

    Science.gov (United States)

    Venneri, Mary Anna; De Palma, Michele; Ponzoni, Maurilio; Pucci, Ferdinando; Scielzo, Cristina; Zonari, Erika; Mazzieri, Roberta; Doglioni, Claudio; Naldini, Luigi

    2007-06-15

    Tumor-infiltrating myeloid cells, including tumor-associated macrophages (TAMs), have been implicated in tumor progression. We recently described a lineage of mouse monocytes characterized by expression of the Tie2 angiopoietin receptor and required for the vascularization and growth of several tumor models. Here, we report that TIE2 expression in human blood identifies a subset of monocytes distinct from classical inflammatory monocytes and comprised within the less abundant "resident" population. These TIE2-expressing monocytes (TEMs) accounted for 2% to 7% of blood mononuclear cells in healthy donors and were distinct from rare circulating endothelial cells and progenitors. In human cancer patients, TEMs were observed in the blood and, intriguingly, within the tumors, where they represented the main monocyte population distinct from TAMs. Conversely, TEMs were hardly detected in nonneoplastic tissues. In vitro, TEMs migrated toward angiopoietin-2, a TIE2 ligand released by activated endothelial cells and angiogenic vessels, suggesting a homing mechanism for TEMs to tumors. Purified human TEMs, but not TEM-depleted monocytes, markedly promoted angiogenesis in xenotransplanted human tumors, suggesting a potentially critical role of TEMs in human cancer progression. Human TEMs may provide a novel, biologically relevant marker of angiogenesis and represent a previously unrecognized target of cancer therapy.

  6. Copper implantation defects in MgO observed by positron beam analysis, RBS and X-TEM

    International Nuclear Information System (INIS)

    Huis, M.A. van; Fedorov, A.V.; Veen, A. van; Smulders, P.J.M.; Kooi, B.J.; Hosson, J.Th.M. de

    2000-01-01

    In this work, effects of copper ion implantation in MgO were studied. (1 0 0) MgO samples were implanted with 50 keV Cu ions and thermally annealed stepwise in air for 30 minutes at 550, 750, 1000, 1250 and 1350 K. After ion implantation and after each annealing step, the samples were analysed with positron beam analysis (PBA). Use was also made of Rutherford backscattering spectrometry/channeling (RBS-C) and cross-sectional transmission electron microscopy (X-TEM). The combination of these techniques enabled to monitor the depth resolved evolution of both created defects and the copper atom depth distribution. PBA results show that copper implantation at a dose of 10 15 ions cm -2 yields a single layer of vacancy type defects after annealing. However a copper implantation at a dose of 10 16 ions cm -2 clearly yields two layers of defects in the material after annealing, separated by an intermediate layer. In both layers nanocavities have been identified. RBS experimental results show that the implanted copper atoms diffuse into the bulk material during annealing. X-TEM and channeling results show that after annealing, the lattice of the copper nanoprecipitates is epitaxial to the MgO host lattice. Under some circumstances, copper precipitates and small voids can co-exist. Furthermore, X-TEM measurements show that the nanocavities have rectangular shapes

  7. Development of a National Consensus for Tactical Emergency Medical Support (TEMS) Training Programs--Operators and Medical Providers.

    Science.gov (United States)

    Schwartz, Richard; Lerner, Brooke; Llwewllyn, Craig; Pennardt, Andre; Wedmore, Ian; Callaway, David; Wightman, John; Casillas, Raymond; Eastman, Alex; Gerold, Kevin; Giebner, Stephen; Davidson, Robert; Kamin, Richard; Piazza, Gina; Bollard, Glenn; Carmona, Phillip; Sonstrom, Ben; Seifarth, William; Nicely, Barbara; Croushorn, John; Carmona, Richard

    2014-01-01

    Tactical teams are at high risk of sustaining injuries. Caring for these casualties in the field involves unique requirements beyond what is provided by traditional civilian emergency medical services (EMS) systems. Despite this need, the training objectives and competencies are not uniformly agreed to or taught. An expert panel was convened that included members from the Departments of Defense, Homeland Security, Justice, and Health and Human Services, as well as federal, state, and local law-enforcement officers who were recruited through requests to stakeholder agencies and open invitations to individuals involved in Tactical Emergency Medical Services (TEMS) or its oversight. Two face-to-face meetings took place. Using a modified Delphi technique, previously published TEMS competencies were reviewed and updated. The original 17 competency domains were modified and the most significant changes were the addition of Tactical Emergency Casualty Care (TECC), Tactical Familiarization, Legal Aspects of TEMS, and Mass Casualty Triage to the competency domains. Additionally, enabling and terminal learning objectives were developed for each competency domain. This project has developed a minimum set of medical competencies and learning objectives for both tactical medical providers and operators. This work should serve as a platform for ensuring minimum knowledge among providers, which will serve enhance team interoperability and improve the health and safety of tactical teams and the public. 2014.

  8. Treating Stress-Related Pain with the Flotation Restricted Environmental Stimulation Technique: Are There Differences between Women and Men?

    Directory of Open Access Journals (Sweden)

    Sven Å Bood

    2009-01-01

    Full Text Available The aim of the present study was to explore, for the first time, sex differences among patients diagnosed with stress-related pain before and after flotation restricted environmental stimulation technique (REST treatment, delivered 12 times during seven weeks. The present study included 88 patients (69 women, 19 men from three different studies (post hoc analysis. They had been diagnosed by a physician as having chronic stress-related muscle tension pain. The analyses indicated that the flotation-REST treatment had beneficial effects on stress, anxiety, depression, sleep quality and pain and that there were few sex differences. Women were more depressed than men before treatment, but after treatment there was no difference between sexes. However, there was a sex difference in the ability to endure experimentally induced pain, suggesting that men exhibited greater endurance both before and after the flotation-REST treatment. The results also showed, for the first time, that both sexes improved their ability to endure experimentally induced pain (higher scores for upper pain threshold following the successful flotation-REST pain treatment.

  9. Health-Related Quality of Life in Children with Celiac Disease: A Study Based on the Critical Incident Technique

    Directory of Open Access Journals (Sweden)

    Carlo Catassi

    2013-11-01

    Full Text Available Celiac Disease (CD is a chronic autoimmune disease triggered by dietary gluten. Gluten avoidance, which is the only available treatment for CD, could impact on quality of life of children with CD. We present the results of a qualitative study on the emotional impact of gluten free diet (GFD on the everyday life of children affected with CD. We investigated 76 celiac patients aged 2–18 years (average age: 9.5 years. By using the Critical Incident Technique (CIT, we defined emotions related to difficulties and awkward situations experienced by the patients. Written answers to open-ended questions from either children (older than 8 years and parents (children younger than 8 years were analyzed qualitatively. We found 80 dilemmas experienced in three different arenas (food situations at school, meals at home, meals outside and characterized lived experiences of children with CD in everyday life (specific emotions, difficulties in relationships and in management of daily life. Children with CD experience strong emotions related to the GFD, permeating several aspects of everyday life. These dilemmas may be missed by a conventional, questionnaire-based approach to the psycho-social consequences of CD treatment.

  10. The use of nuclear related analytical techniques for the determination of ingestion and body content of trace elements

    International Nuclear Information System (INIS)

    Djojosubroto, H.; Santoso, D.; Widjajakusuma, B.

    1998-01-01

    A number of observations revealed that various human disease states are associated with measurable abnormalities of trace element levels. Until present there is no data on trace element levels in human tissues and dietary intake representing the population in Indonesia. Trace element level in various biological materials, especially human serum related to health syndrome (e.g. acute myocardial infarction and goiter prevalences) was performed by National Atomic Energy Agency in cooperation with relevant institutes. The present study is concerned with determination of ingestion and organ content of trace elements of importance in radiological protection (Cs, Sr, I, Th and U). Quantitation of the elements in the samples will be determined by neutron activation analysis, complemented by nuclear related analytical techniques, e.g. inductively coupled plasma - mass spectrometry and atomic absorption spectrometry. Samples to be analyzed consist of (a) total diets and individual staple foodstuffs, (b) autopsy specimens of liver, lung, kidney, muscle, thyroid and bone, and (c) drinking water. It seems difficult for us to define nationally representative specimens of total diets and individual staple foodstuffs. Based on these facts, in the first year activity samples of dietary intake from various socio economic levels of population in West Java will be collected. Human tissue sample is obtained from autopsy of normal persons who are killed in traffic accident or homicide victim. Traces of Th and U in drinking water are determined by neutron activation analysis following preconcentration of these elements in chelating resin Chlelex 100. (author)

  11. Environmental and traffic-related parameters affecting road dust composition: A multi-technique approach applied to Venice area (Italy)

    Science.gov (United States)

    Valotto, Gabrio; Rampazzo, Giancarlo; Visin, Flavia; Gonella, Francesco; Cattaruzza, Elti; Glisenti, Antonella; Formenton, Gianni; Tieppo, Paulo

    2015-12-01

    Road dust is a non-exhaust source of atmospheric particulate by re-suspension. It is composed of particles originating from natural sources as well as other non-exhaust source such as tire, brake and asphalt wear. The discrimination between atmospheric particles directly emitted from abrasion process and those related to re-suspension is therefore an open issue, as far as the percentage contribution of non-exhaust emissions is becoming more considerable due also to the recent policy actions and the technological upgrades in the automotive field, focused on the reduction of exhaust emissions. In this paper, road dust collected along the bridge that connects Venice (Italy) to the mainland is characterized with a multi-technique approach in order to determine its composition depending on environmental as well as traffic-related conditions. Six pollutant sources of road dust particles were identified by cluster analysis: brake, railway, tire, asphalt, soil + marine, and mixed combustions. Considering the lack of information on this matrix in this area, this study is intended to provide useful information for future identification of road dust re-suspension source in atmospheric particulate.

  12. Structural characterizaiton and gas reactions of small metal particles by high-resolution, in-situ TEM and TED

    Science.gov (United States)

    1984-01-01

    The existing in-situ transmission electron microscopy (TEM) facility was improved by adding a separately pumped mini-specimen chamber. The chamber contains wire-evaporation sources for three metals and a specimen heater for moderate substrate temperatures. A sample introduction device was constructed, installed, and tested, facilitating rapid introduction of a specimen into the mini-chamber while maintaining the background pressure in that chamber in the 10(-9) millibar range. Small particles and clusters of Pd, grown by deposition from the vapor phase in an in-situ TEM facility on amorphous and crystalline support films of alumina and on ultra-thin carbon films, were analyzed by conventional high-resolution TEM and image analysis in terms of detectability, number density, and size distribution. The smallest particles that could be detected and counted contained no more than 6 atoms; size determinations could be made for particles 1 nm in diameter. The influence of various oxygen plasma treatments, annealing treatments, and of increasing the substrate temperature during deposition was investigated. The TEM technique was employed to demonstrate that under otherwise identica l conditions the lattice parameter of Pd particles in the 1 to 2 nm size range and supported in random orientation on ex-situ prepared mica films is expanded by some 3% when compared to 5 nm size particles. It is believed that this expansion is neither a small-particle diffraction effect nor due to pseudomorphism, but that it is due to a annealing-induced transformation of the small as-deposited particles with predominantly composite crystal structures into larger particles with true f.c.c. structure and thus inherently smaller lattice parameter.

  13. Electron impact ionization technique on the study of terpenes and related species in French Guiana tropical forest

    International Nuclear Information System (INIS)

    Lopes, Paula Regina Corain; Bustillos, Oscar W.V.; Guenther, Alex B.; Turnipseed, Andrew A.; Emmons, Louisa; Bonal, Damien; Burban, Benoit; Siebicke, Lukas; Serca, Dominique

    2013-01-01

    The electron impact ionization is, originally, a mass spectrometry ionization method and still the most widely used of all ionization methods.In this technique, a beam of electrons passes through the gas phase sample. An electron that collides with a neutral analyte molecule can knock off another electron, resulting in a positively charged ion. The fragmentation process dependent sup on many qualities including primary structure, electron energy and ion source temperature. This paper presents a study on the seasonal variation of isoprene and some other significant biogenic volatile organic compounds (BVOC) such as α-pinene, β-pinene, limonene, e-βocimene and longifolene, measured at the Guyaflux Tower located in a wet tropical forest in French Guiana using the Relaxed Eddy Accumulation technique and analyzed by a mass spectrometer coupled to a gas chromatograph, a thermo desorption unit and a flame ionization detector (TD-GC-MS-FID). The results showed that isoprene was by far the biogenic volatile organic compound with the highest concentration and flux, followed by alpha-pinene. Previous limited studies in Amazonia and the Congo suggested that a higher concentration and flux rate of isoprene and alpha-pinene should be expected during the dry season with lower emissions during the wet season, which is in relative agreement with what was observed at this tropical forest site in French Guiana. The exceptions were observed in a long wet period in which the concentration of isoprene and alpha-pinene increased more than it was expected to, for this time of the year. (author)

  14. Electron impact ionization technique on the study of terpenes and related species in French Guiana tropical forest

    Energy Technology Data Exchange (ETDEWEB)

    Lopes, Paula Regina Corain; Bustillos, Oscar W.V., E-mail: paulinhacorain@usp.br, E-mail: ovega@ipen.br [Instituto de Pesquisa Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Guenther, Alex B.; Turnipseed, Andrew A.; Emmons, Louisa, E-mail: guenther@ucar.edu [Biosphere Atmosphere Interaction Group, Atmosphere Chemistry Division of National Center for Atmospheric Research (NCAR), Boulder, CO (United States); Bonal, Damien; Burban, Benoit; Siebicke, Lukas, E-mail: lukas.siebicke@ecofog.gf [Institut National de la Recherche Agronomique (INRA-UMR EEF), Nancy (France); Serca, Dominique, E-mail: dominique.serca@aero.obs-mip.fr [Universite Paul Sabatier (UPS), Toulouse (France). Laboratoire d' Aerologie

    2013-07-01

    The electron impact ionization is, originally, a mass spectrometry ionization method and still the most widely used of all ionization methods.In this technique, a beam of electrons passes through the gas phase sample. An electron that collides with a neutral analyte molecule can knock off another electron, resulting in a positively charged ion. The fragmentation process dependent sup on many qualities including primary structure, electron energy and ion source temperature. This paper presents a study on the seasonal variation of isoprene and some other significant biogenic volatile organic compounds (BVOC) such as α-pinene, β-pinene, limonene, e-βocimene and longifolene, measured at the Guyaflux Tower located in a wet tropical forest in French Guiana using the Relaxed Eddy Accumulation technique and analyzed by a mass spectrometer coupled to a gas chromatograph, a thermo desorption unit and a flame ionization detector (TD-GC-MS-FID). The results showed that isoprene was by far the biogenic volatile organic compound with the highest concentration and flux, followed by alpha-pinene. Previous limited studies in Amazonia and the Congo suggested that a higher concentration and flux rate of isoprene and alpha-pinene should be expected during the dry season with lower emissions during the wet season, which is in relative agreement with what was observed at this tropical forest site in French Guiana. The exceptions were observed in a long wet period in which the concentration of isoprene and alpha-pinene increased more than it was expected to, for this time of the year. (author)

  15. The p300 event-related potential technique for libido assessment in women with hypoactive sexual desire disorder.

    Science.gov (United States)

    Vardi, Yoram; Sprecher, Elliot; Gruenwald, Ilan; Yarnitsky, David; Gartman, Irena; Granovsky, Yelena

    2009-06-01

    There is a need for an objective technique to assess the degree of hypoactive sexual desire disorder (HSDD). Recently, we described such a methodology (event-related potential technique [ERP]) based on recording of p300 electroencephalography (EEG) waves elicited by auditory stimuli during synchronous exposure to erotic films. To compare sexual interest of sexually healthy women to females with sexual dysfunction (FSD) using ERP, and to explore whether FSD women with and without HSDD would respond differently to two different types of erotic stimuli-films containing (I) or not containing (NI) sexual intercourse scenes. Twenty-two women with FSD, of which nine had HSDD only, and 30 sexually healthy women were assessed by the Female Sexual Functioning Index. ERP methodology was performed applying erotic NI or I films. Significant differences in percent of auditory p300 amplitude reduction (PR) in response to erotic stimuli within and between all three groups for each film type. PRs to each film type were similar in sexually healthy women (60.6% +/- 40.3 (NI) and 51.7% +/- 32.3 [I]), while in women with FSD, reduction was greater when viewing the NI vs. I erotic films (71.4% +/- 41.0 vs. 37.7% +/- 45.7; P = 0.0099). This difference was mainly due to the greater PR of the subgroup with HSDD in response to NI vs. I films (77.7% +/- 46.7 vs. 17.0% +/- 50.3) than in the FSD women without HSDD group or the sexually healthy women (67.5% +/- 38.7 vs. 50.4% +/- 39.4 respectively), P = 0.0084. For comparisons, we used the mixed-model one-way analysis of variance. Differences in neurophysiological response patterns between sexually healthy vs. sexually dysfunctional females may point to a specific inverse discrimination ability for sexually relevant information in the subgroup of women with HSDD. These findings suggest that the p300 ERP technique could be used as an objective quantitative tool for libido assessment in sexually dysfunctional women.

  16. Overall and peripheral lung function assessment by spirometry and forced oscillation technique in relation to asthma diagnosis and control.

    Science.gov (United States)

    Heijkenskjöld Rentzhog, C; Janson, C; Berglund, L; Borres, M P; Nordvall, L; Alving, K; Malinovschi, A

    2017-12-01

    Classic spirometry is effort dependent and of limited value in assessing small airways. Peripheral airway involvement, and relation to poor control, in asthma, has been highlighted recently. Forced oscillation technique (FOT) offers an effort-independent assessment of overall and peripheral lung mechanics. We studied the association between lung function variables, obtained either by spirometry or multifrequency (5, 11 and 19 Hz) FOT, and asthma diagnosis and control. Spirometry measures, resistance at 5 (R5) and 19 Hz (R19), reactance at 5 Hz (X5), resonant frequency (f res ), resistance difference between 5-19 Hz (R5-R19) and Asthma Control Test scores were determined in 234 asthmatic and 60 healthy subjects (aged 13-39 years). We used standardized lung function variables in logistic regression analyses, unadjusted and adjusted for age, height, gender and weight. Lower FEV 1 /FVC (OR [95% CI] 0.47 [0.32, 0.69]) and FEF 50 (0.62 [0.46, 0.85]) per standard deviation increase, and higher R5 (3.31 [1.95, 5.62]) and R19 (2.54 [1.65, 3.91]) were associated with asthma diagnosis. Independent predictive effects of FEV 1 /FVC and R5 or R19, respectively, were found for asthma diagnosis. Lower FEV 1 /FVC and altered peripheral FOT measures (X5, f res and R5-R19) were associated with uncontrolled asthma (P-values < .05). Resistance FOT measures were equally informative as spirometry, related to asthma diagnosis, and, furthermore, offered additive information to FEV 1 /FVC, supporting a complementary role for FOT. Asthma control was related to FOT measures of peripheral airways, suggesting a potential use in identifying such involvement. Further studies are needed to determine a clinical value and relevant reference values in children, for the multifrequency FOT measurements. © 2017 John Wiley & Sons Ltd.

  17. TEM studies of the crystal growth of indanthrone pigments

    International Nuclear Information System (INIS)

    McHendry, P.

    1998-01-01

    The aim of this work was to study the crystal growth of indanthrone during the pigmentation process. The colouring properties of a pigment are dependant on the chemical and crystallographic structure of the pigment. However, other factors are known to affect these properties including particle size, particle size distribution and level of dispersion in the chosen application medium. The parameters which affect the growth of the pigment particles were investigated with the emphasis placed on the mechanism by which growth took place. The final form of the crystals after growth was also investigated in some detail. Various electron microscopy techniques were employed in the investigations in this thesis. High and low magnification imaging and diffraction were studied on the CTEM (conventional transmission electron microscope) whilst PEELS (parallel electron energy loss spectroscopy) and DPC (differential phase contrast) studies took place on the VG HB5 STEM (scanning transmission electron microscope). In addition to these studies, x-ray diffraction and surface area analysis techniques were employed. The low magnification CTEM work gave good information on the size, shape and size distribution of the pigment particles and enabled detailed analysis of the level of growth attained under varied reaction conditions. (author)

  18. Analysis of Premature Wear-Out of Aircraft Gun Barrel by Applying a Transmission Electron Microscopy (TEM

    Directory of Open Access Journals (Sweden)

    Łęczycki Krzysztof

    2017-08-01

    Full Text Available Firing from gun armament generates a wide range of physico-chemical phenomena contributing to the degradation of barrel material, e.g. pressure, high temperature, chemically aggressive character of post-detonation gases and friction of a driving band. In this work the technique of thin foils was used in Transmission Electron Microscopy (TEM to study the influence of physicochemical phenomena on the material microstructure of aircraft gun barrel. A mechanism and reason of premature wear-out of the barrel under consideration was also outlined by utilising light microscopy and hardness measurements.

  19. In situ TEM experiments of electrochemical lithiation and delithiation of individual nanostructures

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Xiao Hua; Liu, Yang; Huang, Jian Yu [Center for Integrated Nanotechnologies (CINT), Sandia National Laboratories, Albuquerque, New Mexico (United States); Kushima, Akihiro; Li, Ju [Department of Nuclear Science and Engineering and Department of Materials Science and Engineering, Massachusetts Institute of Technology, Cambridge, Massachusetts (United States); Zhang, Sulin [Department of Engineering Science and Mechanics, Pennsylvania State University, University Park, Pennsylvania (United States); Zhu, Ting [Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, Georgia (United States)

    2012-07-15

    Understanding the microscopic mechanisms of electrochemical reaction and material degradation is crucial for the rational design of high-performance lithium ion batteries (LIBs). A novel nanobattery assembly and testing platform inside a transmission electron microscope (TEM) has been designed, which allows a direct study of the structural evolution of individual nanowire or nanoparticle electrodes with near-atomic resolution in real time. In this review, recent progresses in the study of several important anode materials are summarized. The consistency between in situ and ex situ results is shown, thereby validating the new in situ testing paradigm. Comparisons between a variety of nanostructures lead to the conclusion that electrochemical reaction and mechanical degradation are material specific, size dependent, and geometrically and compositionally sensitive. For example, a highly anisotropic lithiation in Si is observed, in contrast to the nearly isotropic response in Ge. The Ge nanowires can develop a spongy network, a unique mechanism for mitigating the large volume changes during cycling. The Si nanoparticles show a critical size of {proportional_to}150 nm below which fracture is averted during lithiation, and above which surface cracking, rather than central cracking, is observed. In carbonaceous nanomaterials, the lithiated multi-walled carbon nanotubes (MWCNTs) are drastically embrittled, while few-layer graphene nanoribbons remain mechanically robust after lithiation. This distinct contrast manifests a strong 'geometrical embrittlement' effect as compared to a relatively weak 'chemical embrittlement' effect. In oxide nanowires, discrete cracks in ZnO nanowires are generated near the lithiation reaction front, leading to leapfrog cracking, while a mobile dislocation cloud at the reaction front is observed in SnO{sub 2} nanowires. This contrast is corroborated by ab initio calculations that indicate a strong chemical embrittlement of Zn

  20. PREFACE: International Conference on the Use of X-ray (and related) Techniques in Arts and Cultural Heritage (XTACH 11)

    Science.gov (United States)

    Hamdan, Nasser; El-Khatib, Sami

    2012-07-01

    The International Conference on the Use of X-Ray (and related) Techniques in Arts and Cultural Heritage (XTACH11) was held on 7 and 8 December 2011 at the American University of Sharjah (AUS) in the United Arab Emirates. The conference was organized in collaboration with the International Atomic Energy Agency (IAEA) and the National X-ray Fluorescence Laboratory (NXFL). The conference was inaugurated by Dr Peter Heath, Chancellor of the American University of Shrjah and attended by Mr Kwaku Aning, deputy Director General of the International Atomic Energy and Ambassador Hamad Al-Kaabi, Ambassador of the UAE to the International Atomic Energy university officials, faculty and students. The conference covered a variety of topics including the use of x-ray and micro beam x-ray analysis, synchrotron based techniques, ion beam and neutron based techniques, optical imaging and mass spectroscopy and chromatography techniques as well as best conservation practices. XTACH11 provided an excellent forum for scientists in the region to interact, exchange ideas and to initiate collaborations with each other as well as with the international community. It showcased some of the latest technical developments in the field of non-destructive testing for the diagnosis and conservation of cultural heritage materials. In addition to the presentations by the invited speakers (Rene van Grieken and K Janssens, University of Antwerp, Belgium; Thomas Calligaro, Centre de Recherche et de Restauration des Musees de France; Stefano Ridolfi, Ars Mensurae, Rome, Italy, and Andrzej Markowicz, IAEA, Austria), a total of 25 other research papers were also presented and discussed. Scientists from many countries participated in the conference: Austria, Belgium, Egypt, Italy, India, Iran, Iraq, Jordan, Lebanon, Qatar, Saudi Arabia, Spain, Sri Lanka, Syria, Thailand, the United Arab Emirates and Yemen. The conference concluded with a Discussion Panel. Thomas Calligaro (Centre de Recherché et de

  1. MORPHOLOGICAL ASPECTS OF HUMAN LENS CAPSULES - A COMPARATIVE LM, SEM AND TEM EXAMINATION

    NARCIS (Netherlands)

    JONGEBLOED, WL; KALICHARAN, D; LOS, LI; VANDERVEEN, G; WORST, JGF

    1991-01-01

    Lens capsules of patients of advanced age, obtained after extracapsular cataract surgery, were carefully prepared for a combined LM, TEM and SEM investigation, after preliminary washing and mounting onto a holder in a buffer solution. After pre-fixation with GA, samples were postfixed for LM/TEM and

  2. HUMAN CAPSULE EPITHELIAL-CELL DEGENERATION A LM, SEM AND TEM INVESTIGATION

    NARCIS (Netherlands)

    JONGEBLOED, WL; KALICHARAN, D; WORST, JGF

    1993-01-01

    The degeneration of the capsule epithelium of cataractous lenses has been studied with LM, SEM on TEM with emphases on TEM. The observed degeneration of the epithelial cells can be described as follows: The cell nucleus becomes picnotic and desintegrates as result of change of the chromatin.

  3. Molecular identification of TEM-116 beta-lactamase gene in isolates ...

    African Journals Online (AJOL)

    Purpose: Purpose: To determine TEM-116 beta-lactamase gene prevalence in drug-resistant Pseudomonas aeruginosa isolates from Pakistan. Methods: Sequence analysis of TEM beta-lactamase isolates and their antibiotic susceptibility patterns were carried out. Quantitative bacteriostatic concentrations for commonly ...

  4. XRD and TEM analysis of microstructure in the welding zone of 9Cr ...

    Indian Academy of Sciences (India)

    Unknown

    XRD and TEM analysis of microstructure in the welding zone of. 9Cr–1Mo–V–Nb ... steel, which has highest Cr content in the heat-resisting. Cr–Mo ... This research provides essential ... film samples were observed under TEM and select elec-.

  5. ANALISIS JARINGAN UMTS PADA MENARA ROOFTOP DENGAN MENGGUNAKAN SOFTWARE TEMS INVESTIGATION DAN G-NETTRACK PRO

    OpenAIRE

    Pande Putu Wahyu Pramanda; Pande Ketut Sudiarta; Ngurah Indra ER.

    2016-01-01

    Berkembangnya dunia teknologi telekomunikasi dan informasi sejalan dengan kebutuhan akan kecepatan dan kestabilan akses internet teknologi UMTS. Metode drive test adalah metode yang biasanya digunakan untuk pengukuran kualitas sebuah site. Pihak provider umumnya menggunakan software TEMS Investigation dalam melakukan drive test. Melakukan drive test dengan TEMS Investigation sangatlah tidak praktis dan memerlukan biaya yang besar. Berkembangnya teknologi smartphone membuat drive test dapat di...

  6. Analyzing the Relative Linkages of Land Use and Hydrologic Variables with Urban Surface Water Quality using Multivariate Techniques

    Science.gov (United States)

    Ahmed, S.; Abdul-Aziz, O. I.

    2015-12-01

    We used a systematic data-analytics approach to analyze and quantify relative linkages of four stream water quality indicators (total nitrogen, TN; total phosphorus, TP; chlorophyll-a, Chla; and dissolved oxygen, DO) with six land use and four hydrologic variables, along with the potential external (upstream in-land and downstream coastal) controls in highly complex coastal urban watersheds of southeast Florida, U.S.A. Multivariate pattern recognition techniques of principle component and factor analyses, in concert with Pearson correlation analysis, were applied to map interrelations and identify latent patterns of the participatory variables. Relative linkages of the in-stream water quality variables with their associated drivers were then quantified by developing dimensionless partial least squares (PLS) regression model based on standardized data. Model fitting efficiency (R2=0.71-0.87) and accuracy (ratio of root-mean-square error to the standard deviation of the observations, RSR=0.35-0.53) suggested good predictions of the water quality variables in both wet and dry seasons. Agricultural land and groundwater exhibited substantial controls on surface water quality. In-stream TN concentration appeared to be mostly contributed by the upstream water entering from Everglades in both wet and dry seasons. In contrast, watershed land uses had stronger linkages with TP and Chla than that of the watershed hydrologic and upstream (Everglades) components for both seasons. Both land use and hydrologic components showed strong linkages with DO in wet season; however, the land use linkage appeared to be less in dry season. The data-analytics method provided a comprehensive empirical framework to achieve crucial mechanistic insights into the urban stream water quality processes. Our study quantitatively identified dominant drivers of water quality, indicating key management targets to maintain healthy stream ecosystems in complex urban-natural environments near the coast.

  7. Latent profiles of elite Malaysian athletes’ use of psychological skills and techniques and relations with mental toughness

    Directory of Open Access Journals (Sweden)

    Vellapandian Ponnusamy

    2018-05-01

    Full Text Available Background The majority of past work on athletes’ use of psychological skills and techniques (PSTs has adopted a variable-centered approach in which the statistical relations among study variables are averaged across a sample. However, variable-centered-analyses exclude the possibility that PSTs may be used in tandem or combined in different ways across practice and competition settings. With this empirical gap in mind, the purposes of this study were to identify the number and type of profiles of elite athletes’ use of PSTs, and examine differences between these clusters in terms of their self-reported mental toughness. Methods In this cross-sectional survey study, 285 Malaysian elite athletes (170 males, 115 females aged 15–44 years (M = 18.89, SD = 4.49 completed measures of various PSTs and mental toughness. Latent profile analysis was employed to determine the type and number of profiles that best represent athletes’ reports of their use of PSTs in practice and competition settings, and examine differences between these classes in terms of self-reported mental toughness. Results Our results revealed three profiles (low, moderate, high use in both practice and competition settings that were distinguished primarily according to quantitative differences in the absolute levels of reported use across most of the PSTs assessed in practice and competition settings, which in turn, were differentially related with mental toughness. Specifically, higher use of PSTs was associated with higher levels of mental toughness. Conclusion This study provides one of the first analyses of the different configurations of athletes’ use of PSTs that typify unique subgroups of performers. An important next step is to examine the longitudinal (in stability of such classes and therefore provide insight into the temporal dynamics of different configurations of athletes’ use of PSTs.

  8. Biomonitoring of air pollution in Jamaica through trace-element analysis of epiphytic plants using nuclear and related analytical techniques

    International Nuclear Information System (INIS)

    Vutchkov, M.; Lalor, G.C.; Preston, J.

    1999-01-01

    Air quality has been monitored at selected areas in Jamaica using high volume samplers. The results obtained, showed elevated levels of aluminium in bauxitic areas and very high lead concentrations in urban areas, from 5 to 35 times greater than in rural areas. The lower throughput of the conventional air particulate samplers however, restricts the air quality and health assessment on a nation-wide scale. Biomonitoring offers a cost-effective alternative to air-quality assessment if appropriate indicator species are chosen. The epiphytic lower plants such as lichens and mosses have been used as indicators of regional air quality in several European countries and USA. However, there is not enough studies on lichens and mosses in tropical countries, probably due to the lower occurrence of these species, which cover only 8% of the world's land surface. In Jamaica the epiphytic higher plants, represented by the genus Tillandsia are widely distributed, which make them along with the lichens and mosses potential site-specific bioindicators of air quality. The IAEA Co-ordinated Research Project entitled 'Biomonitoring of Air Pollution in Jamaica Through Trace-Element Analysis of Epiphytic Plants Using Nuclear And Related Analytical Techniques' will address these needs of the country. The primary purpose of the present study was to develop specific bioindicators of atmospheric air pollution in Jamaica, which will provide baseline information for health hazards assessment

  9. Use of nuclear and nuclear-related analytical techniques in studies of trace and minor elements in air pollution

    International Nuclear Information System (INIS)

    Smodis, Borut; Stropnik, Boris

    1994-01-01

    Among nuclear and nuclear-related analytical techniques, neutron activation and X-ray fluorescence analysis are particularly useful for environmental studies owing to their non-destructive character and multi-element capability. In this work, procedures for k o -standardized instrumental neutron activation analysis (INAA) and energy-dispersive X-ray fluorescence (EDXRF) spectrometry for trace and minor elements in air pollution studies were investigated. The methods applied were validated by the analysis of suitable reference materials. Using INAA, 20 experimentally obtained elemental values out of 21 certified and all 29 experimentally obtained values compared with 'consensus' values (for the elements where no certified numbers are available) in two SRMs were statistically indistinguishable. Also, the contents of 28 elements in candidate NIST SRM 1573a Tomato Leaves are reported. The EDXRF results were statistically indistinguishable from certified values for eight out of nine elements in NIST SRM 3087. The detection limit for this method is around at 0.1 μg cm -2 per element, so in BCR CRM No. 128, which is intended for ambient air pollution data, only Fe and Zn out of 14 elements reported in the certificate were detected with acceptable precision (i.e., 10%) owing to the very low air particulate matter loading, lying in the region of only 250 μg cm -2 . (Author)

  10. A state-of-the-art review of continuous monitoring and surveillance techniques in relation to reactor pressure circuit integrity

    International Nuclear Information System (INIS)

    Nichols, R.W.

    1991-01-01

    This report reviews the present state of the art in the application to LWR primary circuit components of techniques for continuous monitoring and surveillance as an aid to structural integrity engineering assessments and to plant-life management. After discussing aspects related to the monitoring of plant operating conditions, particularly with respect to transient recording, the paper discusses neutron noise and vibration/noise measurements. The aspects of stress, temperature and chemical environment monitoring are discussed. Turning to measuring changes in mechanical properties of the structural materials the review first covers surveillance programmes for assessing irradiation embrittlement and then indicates a number of possibilities for the non-destructive monitoring of such changes although it is emphasized that none of these is ready for application without further development, calibration and plant trials. Moving on to the subject of monitoring structural damage the role of in-service inspection (ISI) using non-destructive testing methods is mentioned and the way that other methods, especially acoustic emission measurements, could supplement or in part replace such ISI is discussed. Other subjects covered include loose parts detection and leak detection which again often involve the use of acoustic emission. The paper ends with a short discussion and recommendations on future work and future possibilities

  11. Relation between anchorings of liquid crystals and conformation changes in aligning agents by the Langmuir-Blodgett film technique investigation

    International Nuclear Information System (INIS)

    Zhu, Y.; Lu, Z.; Wei, Y.

    1995-01-01

    The anchoring direction of liquid crystals on a solid substrate surface depends upon many parameters characterizing the liquid-crystal--substrate interface, a variation of which may change this anchoring direction leading to the so-called anchoring transition. Here, based on the Langmuir-Blodgett film technique, we present two model systems to study the relation between anchoring directions and the conformation changes in aligning agents. A double-armed crown ether liquid crystal and a side chain polymer liquid crystal at an air-water interface both show phase transitions, accompanied by conformation changes. However, when the monolayers in different phases were transferred onto solid substrates to orient liquid crystals, we found that for the crown ether material the conformation change can alter the anchoring of liquid crystals between homeotropic and homogeneous alignments, while for the polymer liquid crystal, despite the conformation changes, the liquid crystals can only be aligned homeotropically. The involved mechanisms were briefly discussed in terms of the Landau-type phenomenological theory

  12. On the determination of loop nature in the TEM

    International Nuclear Information System (INIS)

    Jenkins, M.L.

    1997-01-01

    The two direct methods available for determining the nature of small clusters, were studied. Experiments in heavy-ion irradiated Ag and Cu, including comparisons with Black-White contrast analysis (B-W), forced us to conclude that use of the 2-1/2D technique for analysis of faulted loops is impossible because of reciprocal-lattice spike and other effects. We used B-W analysis to study the clusters produced by RT heavy-ion irradiation of Cu. In-situ irradiations were performed in Argonne HVEM-Tandem Facility using 40 and 80 keV Kr + ions. Nearly all the analysable first-layer loops were vacancy in nature. Some deeper cluster were also certainly vacancy. There is no unequivocal evidence for interstitial loops under these conditions. The near impossibility of establishing that interstitial loops are not present, is shown by the fact that a large fraction of loops (over 50%) could not be analyzed either because they did not display clear B-W contrast under any condition or sufficiently consistent B-W contrast under several different operating conditions

  13. Automatic exposure control systems designed to maintain constant image noise: effects on computed tomography dose and noise relative to clinically accepted technique charts.

    Science.gov (United States)

    Favazza, Christopher P; Yu, Lifeng; Leng, Shuai; Kofler, James M; McCollough, Cynthia H

    2015-01-01

    To compare computed tomography dose and noise arising from use of an automatic exposure control (AEC) system designed to maintain constant image noise as patient size varies with clinically accepted technique charts and AEC systems designed to vary image noise. A model was developed to describe tube current modulation as a function of patient thickness. Relative dose and noise values were calculated as patient width varied for AEC settings designed to yield constant or variable noise levels and were compared to empirically derived values used by our clinical practice. Phantom experiments were performed in which tube current was measured as a function of thickness using a constant-noise-based AEC system and the results were compared with clinical technique charts. For 12-, 20-, 28-, 44-, and 50-cm patient widths, the requirement of constant noise across patient size yielded relative doses of 5%, 14%, 38%, 260%, and 549% and relative noises of 435%, 267%, 163%, 61%, and 42%, respectively, as compared with our clinically used technique chart settings at each respective width. Experimental measurements showed that a constant noise-based AEC system yielded 175% relative noise for a 30-cm phantom and 206% relative dose for a 40-cm phantom compared with our clinical technique chart. Automatic exposure control systems that prescribe constant noise as patient size varies can yield excessive noise in small patients and excessive dose in obese patients compared with clinically accepted technique charts. Use of noise-level technique charts and tube current limits can mitigate these effects.

  14. TEM Nanostructural Study of Al-6Si-3Cu-Mg Melt-Spun Ribbons

    Directory of Open Access Journals (Sweden)

    Ismeli Alfonso López

    2008-01-01

    Full Text Available Three quaternary Al-6Si-3Cu-xMg (x = 0.59, 3.80, and 6.78 wt.% alloys were produced by melt-spun and characterized using X-ray diffractometry (XRD, transmission electron microscopy (TEM, and microhardness techniques. Obtained second phases were Al2Cu( for the alloy with 0.59% Mg and Al5Cu2Mg8Si6 (Q for the alloys with 3.80 and 6.78% Mg. These phases are present as 30–50 nm or as 5–10 nm nanoparticles. Alloying elements content in solid solution increased, mainly for Si and Mg. The high alloying elements content in solid solution and the small -Al cell size for melt-spun alloys leads to microhardness values about 2 times higher than those of ingot counterparts. The microhardness increase for melt-spun alloys with 3.80 and 6.78% Mg depends on Mg content in solid solution.

  15. TEM studies of domain formation mechanisms in MnV{sub 2}O{sub 4}

    Energy Technology Data Exchange (ETDEWEB)

    Murakami, Y., E-mail: murakami@tagen.tohoku.ac.jp [Institute of Multidisciplinary Research for Advanced Materials, Tohoku University, Sendai 980-8577 (Japan); Advanced Science Institute, RIKEN, Wako 351-0198 (Japan); Nii, Y.; Arima, T. [Institute of Multidisciplinary Research for Advanced Materials, Tohoku University, Sendai 980-8577 (Japan); Shindo, D. [Institute of Multidisciplinary Research for Advanced Materials, Tohoku University, Sendai 980-8577 (Japan); Advanced Science Institute, RIKEN, Wako 351-0198 (Japan); Yanagisawa, K. [Advanced Science Institute, RIKEN, Wako 351-0198 (Japan); Okinawa Institute of Science and Technology, Onna-son, Okinawa 904-0412 (Japan); Tonomura, A. [Advanced Science Institute, RIKEN, Wako 351-0198 (Japan); Central Research Laboratory, Hitachi Ltd., Hatoyama 350-0395 (Japan); Okinawa Institute of Science and Technology, Onna-son, Okinawa 904-0412 (Japan)

    2013-11-15

    Highlights: ► Irregular shape of the phase boundary, due to the small transformation strain. ► TEM studies demonstrate the essential reduction of net magnetization by cooling. ► Twining morphology provides a key to understating of the anomalous magnetic domains. -- Abstract: Crystallographic and magnetic domains produced in a spinel-type compound MnV{sub 2}O{sub 4}, which exhibits a type of giant magnetostriction attributed to twin boundary motion, have been studied using transmission electron microscopy techniques. Although MnV{sub 2}O{sub 4} undergoes a displacive cubic-to-tetragonal transformation upon cooling, it does not show a well-defined habit plane (i.e. the plane with a specific index that is favored for minimizing the transformation) due to the small elongation/contraction in the lattice. Electron holography demonstrates a considerable reduction in the magnetic signal by cooling the tetragonal phase to 40 K. Despite the elimination of micrometer-scale ferrimagnetic domains, weak magnetic contrast still remained, indicating small residual magnetic domains in particular portions, such as in the crosshatch of twinning pairs.

  16. Growth of Ag-seeded III-V Nanowires and TEM Characterization

    DEFF Research Database (Denmark)

    Lindberg, Anna Helmi Caroline

    appropriate, the density and the vertical yield were obtained. The crystal structures for the grown nanowires have been investigated with TEM.We have also performed additional growths to further understand exactly how the nanowire growth proceeds as well as to understand the limitations of using Ag as a seed......This thesis deals with growth and characterization of GaAs and InAs nanowires. Today Au nanoparticle-seeding together with self-catalyzing are the dominating techniques to grow III-V nanowires with molecular beam epitaxy. In this thesis we instead investigate the possibility to use Ag as seed...... particle for growth of GaAs and InAs nanowires. The aim with the experiments performed has been to conclude whether Ag can be used to nucleate and grow nanowires on III-V substrates with molecular beam epitaxy. To investigate this we have performed growths of GaAs nanowires on GaAs(111)B and GaAs(100...

  17. Investigation of size-fractionated urban aerosol and trace gases in Budapest by nuclear-related and other analytical techniques

    International Nuclear Information System (INIS)

    Salma, I.; Maenhaut, W.; Zemplen-Papp, E.; Bobvos, J.

    1998-01-01

    An air pollution study was conducted at two urban residential sites in Budapest (one representing the downtown, the other representing a wooded suburb) from 9 April till 17 May 1996. Size-fractionated aerosol samples were simultaneously collected on a daily basis, and meteorological conditions were recorded at both sampling sites. Stacked filter units (SFUs) with an upper size inlet cut-off were used as sampling device separating the urban aerosol into a coarse (about 10-2 μm equivalent aerodynamic diameter, EAD) and a fine ( 2 , SO 2 , CO and the total mass of the suspended particulate matter were measured every half hour at one of the sampling sites by commercial equipment. The SFU filters were analyzed by gravimetry for the total particle mass, by a light reflectance technique for black carbon, by particle-induced X-ray emission analysis and instrumental neutron activation analysis for elemental composition (in combination for up to 40-45 elements). The analytical results were used for characterizing the levels and the multi-elemental composition of the urban aerosol at both sampling sites and for both size fractions, for investigating the atmospheric concentrations and diurnal variation of some criteria pollutants, and for comparing the time-trends of aerosols and trace gases. Identification of the major source types of the aerosol fractions and trace gases, and assessment of the relative contribution from these sources are to be accomplished by multivariate receptor modeling. The present paper reports on the status of the air pollution study, and gives a discussion of the results

  18. Understanding neighborhood environment related to Hong Kong children's physical activity: a qualitative study using nominal group technique.

    Directory of Open Access Journals (Sweden)

    Gang He

    Full Text Available BACKGROUND: Relationships between the neighborhood environment and children's physical activity have been well documented in Western countries but are less investigated in ultra-dense Asian cities. The aim of this study was to identify the environmental facilitators and barriers of physical activity behaviors among Hong Kong Chinese children using nominal group technique. METHODS: Five nominal groups were conducted among 34 children aged 10-11 years from four types of neighborhoods varying in socio-economic status and walkability in Hong Kong. Environmental factors were generated by children in response to the question "What neighborhood environments do you think would increase or decrease your willingness to do physical activity?" Factors were prioritized in order of their importance to children's physical activity. RESULTS: Sixteen unique environmental factors, which were perceived as the most important to children's physical activity, were identified. Factors perceived as physical activity-facilitators included "Sufficient lighting", "Bridge or tunnel", "Few cars on roads", "Convenient transportation", "Subway station", "Recreation grounds", "Shopping malls with air conditioning", "Fresh air", "Interesting animals", and "Perfume shop". Factors perceived as physical activity-barriers included "People who make me feel unsafe", "Crimes nearby", "Afraid of being taken or hurt at night", "Hard to find toilet in shopping mall", "Too much noise", and "Too many people in recreation grounds". CONCLUSIONS: Specific physical activity-related environmental facilitators and barriers, which are unique in an ultra-dense city, were identified by Hong Kong children. These initial findings can inform future examinations of the physical activity-environment relationship among children in Hong Kong and similar Asian cities.

  19. Understanding neighborhood environment related to Hong Kong children's physical activity: a qualitative study using nominal group technique.

    Science.gov (United States)

    He, Gang; Cerin, Ester; Huang, Wendy Y; Wong, Stephen H

    2014-01-01

    Relationships between the neighborhood environment and children's physical activity have been well documented in Western countries but are less investigated in ultra-dense Asian cities. The aim of this study was to identify the environmental facilitators and barriers of physical activity behaviors among Hong Kong Chinese children using nominal group technique. Five nominal groups were conducted among 34 children aged 10-11 years from four types of neighborhoods varying in socio-economic status and walkability in Hong Kong. Environmental factors were generated by children in response to the question "What neighborhood environments do you think would increase or decrease your willingness to do physical activity?" Factors were prioritized in order of their importance to children's physical activity. Sixteen unique environmental factors, which were perceived as the most important to children's physical activity, were identified. Factors perceived as physical activity-facilitators included "Sufficient lighting", "Bridge or tunnel", "Few cars on roads", "Convenient transportation", "Subway station", "Recreation grounds", "Shopping malls with air conditioning", "Fresh air", "Interesting animals", and "Perfume shop". Factors perceived as physical activity-barriers included "People who make me feel unsafe", "Crimes nearby", "Afraid of being taken or hurt at night", "Hard to find toilet in shopping mall", "Too much noise", and "Too many people in recreation grounds". Specific physical activity-related environmental facilitators and barriers, which are unique in an ultra-dense city, were identified by Hong Kong children. These initial findings can inform future examinations of the physical activity-environment relationship among children in Hong Kong and similar Asian cities.

  20. Understanding Neighborhood Environment Related to Hong Kong Children’s Physical Activity: A Qualitative Study Using Nominal Group Technique

    Science.gov (United States)

    He, Gang; Cerin, Ester; Huang, Wendy Y.; Wong, Stephen H.

    2014-01-01

    Background Relationships between the neighborhood environment and children’s physical activity have been well documented in Western countries but are less investigated in ultra-dense Asian cities. The aim of this study was to identify the environmental facilitators and barriers of physical activity behaviors among Hong Kong Chinese children using nominal group technique. Methods Five nominal groups were conducted among 34 children aged 10–11 years from four types of neighborhoods varying in socio-economic status and walkability in Hong Kong. Environmental factors were generated by children in response to the question “What neighborhood environments do you think would increase or decrease your willingness to do physical activity?” Factors were prioritized in order of their importance to children’s physical activity. Results Sixteen unique environmental factors, which were perceived as the most important to children’s physical activity, were identified. Factors perceived as physical activity-facilitators included “Sufficient lighting”, “Bridge or tunnel”, “Few cars on roads”, “Convenient transportation”, “Subway station”, “Recreation grounds”, “Shopping malls with air conditioning”, “Fresh air”, “Interesting animals”, and “Perfume shop”. Factors perceived as physical activity-barriers included “People who make me feel unsafe”, “Crimes nearby”, “Afraid of being taken or hurt at night”, “Hard to find toilet in shopping mall”, “Too much noise”, and “Too many people in recreation grounds”. Conclusions Specific physical activity-related environmental facilitators and barriers, which are unique in an ultra-dense city, were identified by Hong Kong children. These initial findings can inform future examinations of the physical activity-environment relationship among children in Hong Kong and similar Asian cities. PMID:25187960

  1. Predatory functional morphology in raptors: interdigital variation in talon size is related to prey restraint and immobilisation technique.

    Science.gov (United States)

    Fowler, Denver W; Freedman, Elizabeth A; Scannella, John B

    2009-11-25

    Despite the ubiquity of raptors in terrestrial ecosystems, many aspects of their predatory behaviour remain poorly understood. Surprisingly little is known about the morphology of raptor talons and how they are employed during feeding behaviour. Talon size variation among digits can be used to distinguish families of raptors and is related to different techniques of prey restraint and immobilisation. The hypertrophied talons on digits (D) I and II in Accipitridae have evolved primarily to restrain large struggling prey while they are immobilised by dismemberment. Falconidae have only modest talons on each digit and only slightly enlarged D-I and II. For immobilisation, Falconini rely more strongly on strike impact and breaking the necks of their prey, having evolved a 'tooth' on the beak to aid in doing so. Pandionidae have enlarged, highly recurved talons on each digit, an adaptation for piscivory, convergently seen to a lesser extent in fishing eagles. Strigiformes bear enlarged talons with comparatively low curvature on each digit, part of a suite of adaptations to increase constriction efficiency by maximising grip strength, indicative of specialisation on small prey. Restraint and immobilisation strategy change as prey increase in size. Small prey are restrained by containment within the foot and immobilised by constriction and beak attacks. Large prey are restrained by pinning under the bodyweight of the raptor, maintaining grip with the talons, and immobilised by dismemberment (Accipitridae), or severing the spinal cord (Falconini). Within all raptors, physical attributes of the feet trade off against each other to attain great strength, but it is the variable means by which this is achieved that distinguishes them ecologically. Our findings show that interdigital talon morphology varies consistently among raptor families, and that this is directly correlative with variation in their typical prey capture and restraint strategy.

  2. Communication-related behavior change techniques used in face-to-face lifestyle interventions in primary care: A systematic review of the literature

    NARCIS (Netherlands)

    Noordman, J.; Weijden, T.T. van der; Dulmen, A.M. van

    2012-01-01

    OBJECTIVES: To systematically review the literature on the relative effectiveness of face-to-face communication-related behavior change techniques (BCTs) provided in primary care by either physicians or nurses to intervene on patients' lifestyle behavior. METHODS: PubMed, EMBASE, PsychINFO, CINAHL

  3. Communication-related behavior change techniques used in face-to-face lifestyle interventions in primary care: a systematic review of the literature.

    NARCIS (Netherlands)

    Noordman, J.; Weijden, T. van der; Dulmen, S. van

    2012-01-01

    Objectives: To systematically review the literature on the relative effectiveness of face-to-face communication-related behavior change techniques (BCTs) provided in primary care by either physicians or nurses to intervene on patients’ lifestyle behavior. Methods: PubMed, EMBASE, PsychINFO, CINAHL

  4. TEM studies of nanostructure in melt-spun Mg-Ni-La alloy manifesting enhanced hydrogen desorbing kinetics

    International Nuclear Information System (INIS)

    Tanaka, K.; Miwa, T.; Sasaki, K.; Kuroda, K.

    2009-01-01

    The hydrogen storage properties of a magnesium-rich Mg-Ni-La alloy prepared by melt-spinning are significantly improved by nanostructure formation during crystallization and activation. It can absorb and desorb ∼5 wt% hydrogen at temperatures as low as 200 deg. C in moderate time periods. Transmission electron microscopic (TEM) studies on this alloy indicate that the nanostructure, consisting of LaH 3 and Mg 2 NiH 4 nano-particles dispersed homogeneously in MgH 2 matrices after hydrogenation, is rather stable at temperatures below 300 deg. C but undergoes coarsening and segregation of these particles and matrices above ∼400 deg. C. These structural changes have been confirmed by electron energy-loss spectroscopic (EELS) imaging as well as high-resolution TEM techniques. A new EELS peak associated with a plasmon excitation in the MgH 2 phase (H-plasmon) is found for the first time in this study. By imaging the H-plasmon peak, the hydrogen distribution in the alloy has been clearly visualized. We have succeeded in observing the hydrogen desorption process at ∼400 deg. C in-situ in the microscope using this EELS imaging technique.

  5. Are we Breathing Clean Air in Metro Manila? (Nuclear and Related Analytical Techniques and Receptor Modeling Revealing the Real Score)

    International Nuclear Information System (INIS)

    Pabroa, Preciosa Corazon B.

    2015-01-01

    Air Particulate matter (APM) is a mixture of different pollutant sources which can be of anthropogenic and/or natural origin, of which the size of great concern with regard to adverse effects on human health are generally less than 10μm (Referred to as PM10). Identification and apportionment of pollutant sources is important to be able to have better understanding of prevailing conditions in the area and thus better air quality management can be applied. APM (PM10) at sampling sites in Metro Manila (Philippines) has been monitored since 1998 for the primary purpose of source identification and source apportionment. APM samples (fractionated into coarse (PM2.5-10) and fine (PM2.5) fractions) were collected using a Gent air sampler. Particulate mass was determined by gravimetry and black carbon by reflectometry organic carbon/elemental carbon by thermal optical reflectance. Elemental concentrations were determined using nuclear and related analytical techniques such as the particle-induced x-ray emission (PIXE) spectrometry and x-ray fluorescence (XRF) spectrometry. Source apportionment of fine air particles was done using PMF2. Result show PM10 levels to be in compliance to the Philippine 1-year guideline value of 60 μg m“-“3 but in exceedance of the US EPA 1-year standard of 15 μg m“-“3 and the WHO 1-year guideline value of 10 μg m“-“3. Annual mean % Fine BC levels range from 33% to 59%, but individual points can reach up to more than 80% of the PM2.5 levels. Pb level in the fine fraction exhibit decreasing trend coinciding with the introduction of unleaded-gasoline starting in 1998 and the eventual phase-out of the use of leaded-gasoline in 2001. Six air pollution sources have been identified in the fine fraction with vehicular emissions making up the bulk at about 50%. Other sources are smoke, secondary S, fine soil and industry. Addressing problems regarding traffic-related activities can greatly reduce the fine particulate pollution problems

  6. Patient-related quality assurance with different combinations of treatment planning systems, techniques, and machines. A multi-institutional survey

    Energy Technology Data Exchange (ETDEWEB)

    Steiniger, Beatrice; Schwedas, Michael; Weibert, Kirsten; Wiezorek, Tilo [University Hospital Jena, Department of Radiation Oncology, Jena (Germany); Berger, Rene [SRH Hospital Gera, Department of Radiation Oncology, Gera (Germany); Eilzer, Sabine [Martin-Luther-Hospital, Radiation Therapy, Berlin (Germany); Kornhuber, Christine [University Hospital Halle, Department of Radiation Oncology, Halle (Saale) (Germany); Lorenz, Kathleen [Hospital of Chemnitz, Department for Radiation Oncology, Chemnitz (Germany); Peil, Torsten [MVZ Center for Radiation Oncology Halle GmbH, Halle (Saale) (Germany); Reiffenstuhl, Carsten [University Hospital Carl Gustav Carus, Department of Radiation Oncology, Dresden (Germany); Schilz, Johannes [Helios Hospital Erfurt, Department of Radiation Oncology, Erfurt (Germany); Schroeder, Dirk [SRH Central Hospital Suhl, Department of Radiation Oncology, Suhl (Germany); Pensold, Stephanie [Community Hospital Dresden-Friedrichstadt, Department of Radiation Oncology, Dresden (Germany); Walke, Mathias [Otto-von-Guericke University Magdeburg, Department of Radiation Oncology, Magdeburg (Germany); Wolf, Ulrich [University Hospital Leipzig, Department of Radiation Oncology, Leipzig (Germany)

    2017-01-15

    This project compares the different patient-related quality assurance systems for intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) techniques currently used in the central Germany area with an independent measuring system. The participating institutions generated 21 treatment plans with different combinations of treatment planning systems (TPS) and linear accelerators (LINAC) for the QUASIMODO (Quality ASsurance of Intensity MODulated radiation Oncology) patient model. The plans were exposed to the ArcCHECK measuring system (Sun Nuclear Corporation, Melbourne, FL, USA). The dose distributions were analyzed using the corresponding software and a point dose measured at the isocenter with an ionization chamber. According to the generally used criteria of a 10 % threshold, 3 % difference, and 3 mm distance, the majority of plans investigated showed a gamma index exceeding 95 %. Only one plan did not fulfill the criteria and three of the plans did not comply with the commonly accepted tolerance level of ±3 % in point dose measurement. Using only one of the two examined methods for patient-related quality assurance is not sufficiently significant in all cases. (orig.) [German] Im Rahmen des Projekts sollten die verschiedenen derzeit im mitteldeutschen Raum eingesetzten patientenbezogenen Qualitaetssicherungssysteme zur intensitaetsmodulierten Radiotherapie (IMRT) und volumenmodulierten Arc-Radiotherapie (VMAT) mit einem unabhaengigen Messsystem verglichen werden. Die teilnehmenden Einrichtungen berechneten insgesamt 21 Bestrahlungsplaene mit verschiedenen Planungssystemen (TPS) und Linearbeschleunigern (LINAC) fuer das Patientenmodell QUASIMODO (Quality ASsurance of Intensity MODulated radiation Oncology), die dann auf das ArcCHECK-Phantom (Sun Nuclear Corporation, Melbourne, FL, USA) uebertragen und abgestrahlt wurden. Zur Auswertung wurde sowohl eine Punktmessung im Isozentrum als auch die Dosisverteilung in der Diodenebene des

  7. Geoelectrical characterization by joint inversion of VES/TEM in Paraná basin, Brazil

    Science.gov (United States)

    Bortolozo, C. A.; Couto, M. A.; Almeida, E. R.; Porsani, J. L.; Santos, F. M.

    2012-12-01

    For many years electrical (DC) and transient electromagnetic (TEM) soundings have been used in a great number of environmental, hydrological and mining exploration studies. The data of both methods are interpreted usually by individual 1D models resulting in many cases in ambiguous models. This can be explained by how the two different methodologies sample the subsurface. The vertical electrical sounding (VES) is good on marking very resistive structures, while the transient electromagnetic sounding (TEM) is very sensitive to map conductive structures. Another characteristic is that VES is more sensitive to shallow structures, while TEM soundings can reach deeper structures. A Matlab program for joint inversion of VES and TEM soundings, by using CRS algorithm was developed aiming explore the best of the both methods. Initially, the algorithm was tested with synthetic data and after it was used to invert experimental data from Paraná sedimentary basin. We present the results of a re-interpretation of 46 VES/TEM soundings data set acquired in Bebedouro region in São Paulo State - Brazil. The previous interpretation was based in geoelectrical models obtained by single inversion of the VES and TEM soundings. In this work we present the results with single inversion of VES and TEM sounding inverted by the Curupira Program and a new interpretation based in the joint inversion of both methodologies. The goal is increase the accuracy in determining the underground structures. As a result a new geoelectrical model of the region is obtained.

  8. TEM assessment of defects in (CdHg)Te heterostructures

    International Nuclear Information System (INIS)

    Lawson-Jack, S.G.; Jones, I.P.; Williams, D.J.; Astles, M.G.

    1991-01-01

    This paper reports on transmission electron microscopy used to assess the defect contents of the various layers and interfaces in (CdHg)Te heterostructures. Examination of cross sectional specimens of these materials suggests that the density of misfit dislocations at the interfaces is related to the layer thicknesses, and that the high density of dislocations which are generated at the GaAs/CdTe interface are effectively prevented from penetrating into the CdHgTe epilayer by a 3 μm thick buffer layer. The majority of the dislocations in the layers were found to have a Burgers vector b = a/2 left-angle 110 right-angle and either lie approximately parallel or inclined at an angle of ∼ 60 degrees to the interfactial plane

  9. Ranking TEM cameras by their response to electron shot noise

    International Nuclear Information System (INIS)

    Grob, Patricia; Bean, Derek; Typke, Dieter; Li, Xueming; Nogales, Eva; Glaeser, Robert M.

    2013-01-01

    We demonstrate two ways in which the Fourier transforms of images that consist solely of randomly distributed electrons (shot noise) can be used to compare the relative performance of different electronic cameras. The principle is to determine how closely the Fourier transform of a given image does, or does not, approach that of an image produced by an ideal camera, i.e. one for which single-electron events are modeled as Kronecker delta functions located at the same pixels where the electrons were incident on the camera. Experimentally, the average width of the single-electron response is characterized by fitting a single Lorentzian function to the azimuthally averaged amplitude of the Fourier transform. The reciprocal of the spatial frequency at which the Lorentzian function falls to a value of 0.5 provides an estimate of the number of pixels at which the corresponding line-spread function falls to a value of 1/e. In addition, the excess noise due to stochastic variations in the magnitude of the response of the camera (for single-electron events) is characterized by the amount to which the appropriately normalized power spectrum does, or does not, exceed the total number of electrons in the image. These simple measurements provide an easy way to evaluate the relative performance of different cameras. To illustrate this point we present data for three different types of scintillator–coupled camera plus a silicon-pixel (direct detection) camera. - Highlights: ► Fourier amplitude spectra of noise are well fitted by a single Lorentzian. ► This measures how closely, or not, the response approaches the single-pixel ideal. ► Noise in the Fourier amplitudes is (1−π/4) times the shot noise power spectrum. ► Finite variance in the single-electron responses adds to the output noise. ► This excess noise may be equal to or greater than shot noise itself

  10. Novel Techniques and Their Wide Applications to Health Foods, Medical and Agricultural Biotechnology in Relation to Policy Making on Genetically Modified Crops and Foods

    CERN Document Server

    Baianu, I C; Lozano, P; Lin, H C

    2004-01-01

    Selected applications of novel techniques in Agricultural Biotechnology, Health Food formulations and Medical Biotechnology are being reviewed with the aim of unraveling future developments and policy changes that are likely to open new markets for Biotechnology and prevent the shrinking or closing of existing ones. Amongst the selected novel techniques with applications in both Agricultural and Medical Biotechnology are: immobilized bacterial cells and enzymes, microencapsulation and liposome production, genetic manipulation of microorganisms, development of novel vaccines from plants, epigenomics of mammalian cells and organisms, and biocomputational tools for molecular modeling related to disease and Bioinformatics. Both fundamental and applied aspects of the emerging new techniques are being discussed in relation to their anticipated, marked impact on future markets and present policy changes that are needed for success in either Agricultural or Medical Biotechnology. The novel techniques are illustrated ...

  11. In situ TEM observations of unusual nanocrystallization in a Ti-based bulk metallic glass

    International Nuclear Information System (INIS)

    Yan, M.; Wang, D.J.; Shen, J.; Qian, M.

    2011-01-01

    In situ transmission electron microscopy (TEM) has been used to witness the nanocrystallization of amorphous Ti 42.5 Cu 40 Zr 10 Ni 5 Sn 2.5 . A crystallization front exists to separate the TEM sample into two parts with different thermal stabilities. The number density of the crystallization products varies significantly, with the precipitate sizes ranging from a few nanometres to ∼100 nm. Detailed TEM analysis suggests that oxygen is the most likely reason for realizing the unusual nanocrystallization. External thermal analysis also indicates that oxygen affects the crystallization.

  12. TEM investigation of the microstructural evolution in nickel during MeV helium implantation

    International Nuclear Information System (INIS)

    Gadalla, A.A.; Jaeger, W.; Ehrhart, P.

    1986-01-01

    In a recent TEM investigation of high energy He-implanted copper the low average helium density could be understood by the observation of the coexistence of two types of vacancy agglomerates i.e. relaxed vacancy agglomerates in the form of stacking fault tetrahedra (SFT) and small bubbles. In order to arrive at a more systematic understanding of the evolution of the microstructure during high energy helium implantation we extended these TEM investigations to nickel. Of particular interest was also the minimum implantation dose necessary to precipitate bubbles that are large enough to be visible in the TEM. (orig./RK)

  13. Tie2-expressing monocytes (TEMs): novel targets and vehicles of anticancer therapy?

    Science.gov (United States)

    De Palma, Michele; Naldini, Luigi

    2009-08-01

    There is a growing interest in understanding the complex interactions between bone marrow-derived myeloid-lineage cells and angiogenesis in tumors. Such interest has been revived recently by the observation that tumor-infiltrating myeloid cells convey proangiogenic programs that can counteract the activity of antiangiogenic drugs in mouse tumor models. Among myeloid cells, Tie2-expressing monocytes (TEMs) appear to have nonredundant function in promoting tumor angiogenesis and growth in mouse models. The identification and functional characterization of TEMs in mice and humans may provide novel molecular targets for anticancer therapy. Moreover, TEMs may be exploited to deliver antitumor drugs specifically to the tumor microenvironment.

  14. Obtaining TEM images with a uniform deviation parameter

    International Nuclear Information System (INIS)

    Eades, Alwyn

    2006-01-01

    In transmission electron microscopes made during the last quarter of a century, it has been impossible to take images in which the diffraction contrast conditions are uniform across the field of view. This is inconvenient when, for example, imaging dislocations at a relatively low magnification. The problem arises because modern microscopes use immersion lenses in which the sample sits in a high magnetic field. The resulting helical trajectories of the electrons at the sample plane mean that it is not possible to make a beam that is parallel at the sample. Results of a method to overcome this problem are presented. It is shown that a simple modification to the microscope (which, on a computer-controlled microscope, could be implemented in software) can be used to produce images in which the deviation parameter is essentially constant across many microns of image. By a happy accident, this method can be used, not only to correct for the helicity imparted by immersion lenses, but also to correct for buckling of the sample (up to a point)

  15. Parental acceptance of behaviour-management techniques used in paediatric dentistry and its relation to parental dental anxiety and experience.

    Science.gov (United States)

    Boka, V; Arapostathis, K; Vretos, N; Kotsanos, N

    2014-10-01

    The aim of this study was to examine the acceptance by Greek parents of nine behaviour-management techniques and its association with several possible confounding factors. Following ethical approval, 106 parents whose 3- to 12-year-old children had been receiving treatment in a university postgraduate paediatric dental clinic, and 123 parents of children from a private paediatric dental practice agreed to participate. After being shown a video with nine behaviour-management techniques, parents rated the acceptance of each technique on a 0-10 scale. They were then asked to complete a questionnaire about demographics, their previous dental experience and dental anxiety (modified Corah dental anxiety scale). The best accepted technique was tell-show-do (9.76 ± 0.69), followed by parental presence/absence (PPA) technique (7.83 ± 3.06) and nitrous oxide inhalation sedation (7.09 ± 3.02). The least accepted techniques were passive restraint (4.21 ± 3.84) and general anaesthesia (4.21 ± 4.02). No correlations were found between acceptance of any individual management technique and parental age, gender, income, education, dental experience and dental anxiety or the child's age, gender and dental experience. Parents whose children had been treated at the University clinic had lower income and educational levels, and rated passive restraint, oral sedation and general anaesthesia higher than those from the private practice. When the parents were specifically asked to choose between general anaesthesia over any of the active or passive restraint, hand-over-mouth and voice control techniques, 10% preferred general anaesthesia, and these parents reported statistically significant more negative dental experience but not higher dental anxiety. Statistical significance of differences was explored using the Tukey-Kramer method. There was no correlation between parental dental experience and dental anxiety and the acceptance of any specific behaviour-management technique

  16. Short-term Local Forecasting by Artificial Intelligence Techniques and Assess Related Social Effects from Heterogeneous Data

    OpenAIRE

    Gong, Bing

    2017-01-01

    This work aims to use the sophisticated artificial intelligence and statistic techniques to forecast pollution and assess its social impact. To achieve the target of the research, this study is divided into several research sub-objectives as follows: First research sub-objective: propose a framework for relocating and reconfiguring the existing pollution monitoring networks by using feature selection, artificial intelligence techniques, and information theory. Second research sub-objective: c...

  17. Ergonomic factors related to drop-off detection with the long cane: effects of cane tips and techniques.

    Science.gov (United States)

    Kim, Dae Shik; Emerson, Robert S Wall; Curtis, Amy B

    2010-06-01

    This study examined the effect of cane tips and cane techniques on drop-off detection with the long cane. Blind pedestrians depend on a long cane to detect drop-offs. Missing a drop-off may result in falls or collision with moving vehicles in the street. Although cane tips appear to affect a cane user's ability to detect drop-offs, few experimental studies have examined such effect. A repeated-measures design with block randomization was used for the study. Participants were 17 adults who were legally blind and had no other disabilities. Participants attempted to detect the drop-offs of varied depths using different cane tips and cane techniques. Drop-off detection rates were similar between the marshmallow tip (77.0%) and the marshmallow roller tip (79.4%) when both tips were used with the constant contact technique, p = .294. However, participants detected drop-offs at a significantly higher percentage when they used the constant contact technique with the marshmallow roller tip (79.4%) than when they used the two-point touch technique with the marshmallow tip (63.2%), p marshmallow roller tip (perceived as a less advantageous tip) was more effective than the two-point touch technique used with a marshmallow tip (perceived as a more advantageous tip) in detecting drop-offs. The findings of the study may help cane users and orientation and mobility specialists select appropriate cane techniques and cane tips in accordance with the cane user's characteristics and the nature of the travel environment.

  18. Size Determination of Au Aerosol Nanoparticles by Off-Line TEM/STEM Observations

    Science.gov (United States)

    Karlsson, Lisa S.; Deppert, Knut; Malm, Jan-Olle

    2006-12-01

    Determination of particle size distributions of Au aerosol nanoparticles has been performed by a TEM/STEM investigation. The particles are generated by an evaporation/condensation method and are size-selected by differential mobility analyzers (DMA) based on their electrical mobility. Off-line TEM measurements resulted in equivalent projected area diameters assuming that the particles are spherical in shape. In this paper critical factors such as magnification calibration, sampling, image analysis, beam exposure and, particle shape are treated. The study shows that the measures of central tendency; mean, median and mode, are equal as expected from a narrow size distribution. Moreover, the correlation between TEM/STEM and DMA are good, in practice 1:1. Also, STEM has the advantage over TEM due to enhanced contrast and is proposed as an alternative route for determination of particle size distributions of nanoparticles with lower contrast.

  19. Size Determination of Au Aerosol Nanoparticles by Off-Line TEM/STEM Observations

    International Nuclear Information System (INIS)

    Karlsson, Lisa S.; Deppert, Knut; Malm, Jan-Olle

    2006-01-01

    Determination of particle size distributions of Au aerosol nanoparticles has been performed by a TEM/STEM investigation. The particles are generated by an evaporation/condensation method and are size-selected by differential mobility analyzers (DMA) based on their electrical mobility. Off-line TEM measurements resulted in equivalent projected area diameters assuming that the particles are spherical in shape. In this paper critical factors such as magnification calibration, sampling, image analysis, beam exposure and, particle shape are treated. The study shows that the measures of central tendency; mean, median and mode, are equal as expected from a narrow size distribution. Moreover, the correlation between TEM/STEM and DMA are good, in practice 1:1. Also, STEM has the advantage over TEM due to enhanced contrast and is proposed as an alternative route for determination of particle size distributions of nanoparticles with lower contrast

  20. TEM characterization of UO2-Gd2O3 nuclear fuels synthesized by coprecipitation method

    International Nuclear Information System (INIS)

    Soldati, A.; Gana Watkins, I.; Menghini, J.; Prado, M.

    2013-01-01

    We present a micro and nano structural characterization of 4% weight doped Gd 2 O 3 -UO 2 pellet using Transmission Electron Microscopy (TEM). Agglomerate morphology and crystallite sizes were determined using light/dark field and high resolution (HR-TEM) images. Convergent beam Energy Dispersive Spectroscopy (EDS) and Electron Diffraction (ED) were used to evaluate sample composition and homogeneity, even at the nanometer scale. We obtained an average crystallite size of 90±20 nm. Moreover, from TEM-EDS analyses we determined the presence of Gadolinium in all the analyzed crystallites but with 25% variation among their concentrations. These results show the capability of TEM analysis to characterize a nuclear fuel pellet with burnable poisons nano structure and homogeneity.(author)

  1. ANALISIS JARINGAN UMTS PADA MENARA ROOFTOP DENGAN MENGGUNAKAN SOFTWARE TEMS INVESTIGATION DAN G-NETTRACK PRO

    Directory of Open Access Journals (Sweden)

    Pande Putu Wahyu Pramanda

    2016-03-01

    Full Text Available Berkembangnya dunia teknologi telekomunikasi dan informasi sejalan dengan kebutuhan akan kecepatan dan kestabilan akses internet teknologi UMTS. Metode drive test adalah metode yang biasanya digunakan untuk pengukuran kualitas sebuah site. Pihak provider umumnya menggunakan software TEMS Investigation dalam melakukan drive test. Melakukan drive test dengan TEMS Investigation sangatlah tidak praktis dan memerlukan biaya yang besar. Berkembangnya teknologi smartphone membuat drive test dapat dilakukan dengan menggunakan handphone yaitu dengan G-NetTrack Pro. Namun G-NetTrack Pro tidak memiliki kemampuan yang sama dengan TEMS Investigation. Software G-NetTrack Pro dapat digunakan sebagai bahan pembelajaran yaitu untuk pengenalan drivetest namun belum cocok digunakan secara profesional. G-NetTrack Pro dapat menampilkan data yang dibutuhkan dalam drive test namun tidak sedetail TEMS Investigation, sehingga dalam proses pembelajaran dapat digunakan untuk pengenalan karena efisien dan dapat di install pada handphone mahasiswa namun tidak dapat digunakan melakukan drive test misalnya dalam dunia kerja atau secara professional.

  2. Interpretation of interfacial structures in X-ray multilayers by TEM Fresnel fringe effects

    OpenAIRE

    Nguyen, Tai D.; O'Keefe, Michael A.; Kilaas, Roar; Gronsky, Ronald; Kortright, Jeffrey B.

    1991-01-01

    Assessment of interfacial structures from high-resolution TEM images of cross-sectional specimens is difficult due to Fresnel fringe effects producing different apparent structures in the images. The effects of these fringes have been commonly over-looked in efforts of making quantitative interpretation of interfacial profiles. In this report, we present the observations of the Fresnel fringes in nanometer period Mo/Si, W/C, and WC/C multilayers in through-focus-series TEM images. Calculation...

  3. Maredata: red temática sobre datos de investigación en abierto

    OpenAIRE

    Abadal Falgueras, Ernest; Aleixandre, Rafael; Canals, Agustí; Ferrer, Antonia; Garrigós, Irene; Hernández, Tony; López-Borrull, Alexandre; Mazón, José N.; Melero Melero, Remedios; Méndez Rodríguez, Eva María; Ollé, Eva; Peset Mancebo, María Fernanda

    2017-01-01

    [ES]El objetivo central de la red temática MAREDATA es aglutinar y consolidar la colaboración entre grupos de investigación españoles centrados en el estudio de los datos científicos y también establecer relación con aquellos sectores y disciplinas interesados en esta temática.

  4. Recent advances in cryo-TEM imaging of soft lipid nanoparticles

    DEFF Research Database (Denmark)

    Helvig, Shen Yu; Mat Azmi, Intan Diana Binti; Moghimi, Seyed Moien

    2015-01-01

    Cryo-transmission electron microscopy (Cryo-TEM), and its technological variations thereof, have become a powerful tool for detailed morphological characterization and 3D tomography of soft lipid and polymeric nanoparticles as well as biological materials such as viruses and DNA without chemical...... fixation. Here, we review and discuss recent advances in Cryo-TEM analysis of lipid-based drug nanocarriers with particular emphasis on morphological and internal nanostructure characterization of lyotropic liquid crystalline nanoparticles such as cubosomes and hexosomes....

  5. Sub-surface microstructure of single and polycrystalline tungsten after high flux plasma exposure studied by TEM

    Energy Technology Data Exchange (ETDEWEB)

    Dubinko, A., E-mail: adubinko@sckcen.be [Institute for Nuclear Material Sciences, SCK-CEN, 2400 Mol (Belgium); Department of Applied Physics, Ghent University, 9000 Ghent (Belgium); Terentyev, D. [Institute for Nuclear Material Sciences, SCK-CEN, 2400 Mol (Belgium); Bakaeva, A. [Institute for Nuclear Material Sciences, SCK-CEN, 2400 Mol (Belgium); Department of Applied Physics, Ghent University, 9000 Ghent (Belgium); Hernández-Mayoral, M. [Division of Materials, CIEMAT, 28040 Madrid (Spain); De Temmerman, G. [ITER Organization, Route de Vinon-sur-Verdon, CS 90 046, 13067 St Paul-lez-Durance Cedex (France); Buzi, L. [Forschungszentrum Julich, Inst. Energie & Klimaforsch Plasmaphys, D-52425 Julich (Germany); Noterdaeme, J.-M. [Department of Applied Physics, Ghent University, 9000 Ghent (Belgium); Unterberg, B. [Forschungszentrum Julich, Inst. Energie & Klimaforsch Plasmaphys, D-52425 Julich (Germany)

    2017-01-30

    Highlights: • Plasma exposure induces dislocation-dominated microstructure as indicated by TEM. • Plasma exposure increases surface dislocation density by an order of magnitude in the polycrystalline tungsten. • Intensive dislocation-grain boundary interaction observed in polycrystalline tungsten. • Dislocation loops are observed in both polycrystalline and single crystal tungsten. - Abstract: We have performed high flux plasma exposure of tungsten and subsequent microstructural characterization using transmission electron microscopy (TEM) techniques. The aim was to reveal the nanometric features in the sub-surface region as well as to compare the microstructural evolution in tungsten single crystal and ITER-relevant specification. In both types of samples, TEM examination revealed the formation of a dense dislocation network and dislocation tangles. The estimated dislocation density in the sub-surface region was of the order of 10{sup 14} m{sup −2} and it gradually decreased with a depth position of the examined sample. Besides individual dislocation lines, networks and tangles, the interstitial dislocation loops have been observed in all examined samples only after the exposure. Contrary to that, examination of the pristine single crystal W and backside of the plasma-exposed samples did not reveal the presence of dislocation loops and tangles. This clearly proves that high flux plasma exposure induces severe plastic deformation in the sub-surface region irrespective of the presence of initial dislocations and sub-grains, and the formation of dislocation tangles, networks and interstitial loops is a co-product of thermal stress and intensive plasma particles uptake.

  6. TEM in situ cube-corner indentation analysis using ViBe motion detection algorithm

    Science.gov (United States)

    Yano, K. H.; Thomas, S.; Swenson, M. J.; Lu, Y.; Wharry, J. P.

    2018-04-01

    Transmission electron microscopic (TEM) in situ mechanical testing is a promising method for understanding plasticity in shallow ion irradiated layers and other volume-limited materials. One of the simplest TEM in situ experiments is cube-corner indentation of a lamella, but the subsequent analysis and interpretation of the experiment is challenging, especially in engineering materials with complex microstructures. In this work, we: (a) develop MicroViBE, a motion detection and background subtraction-based post-processing approach, and (b) demonstrate the ability of MicroViBe, in combination with post-mortem TEM imaging, to carry out an unbiased qualitative interpretation of TEM indentation videos. We focus this work around a Fe-9%Cr oxide dispersion strengthened (ODS) alloy, irradiated with Fe2+ ions to 3 dpa at 500 °C. MicroViBe identifies changes in Laue contrast that are induced by the indentation; these changes accumulate throughout the mechanical loading to generate a "heatmap" of features in the original TEM video that change the most during the loading. Dislocation loops with b = ½ identified by post-mortem scanning TEM (STEM) imaging correspond to hotspots on the heatmap, whereas positions of dislocation loops with b = do not correspond to hotspots. Further, MicroViBe enables consistent, objective quantitative approximation of the b = ½ dislocation loop number density.

  7. VES/TEM 1D joint inversion by using Controlled Random Search (CRS) algorithm

    Science.gov (United States)

    Bortolozo, Cassiano Antonio; Porsani, Jorge Luís; Santos, Fernando Acácio Monteiro dos; Almeida, Emerson Rodrigo

    2015-01-01

    Electrical (DC) and Transient Electromagnetic (TEM) soundings are used in a great number of environmental, hydrological, and mining exploration studies. Usually, data interpretation is accomplished by individual 1D models resulting often in ambiguous models. This fact can be explained by the way as the two different methodologies sample the medium beneath surface. Vertical Electrical Sounding (VES) is good in marking resistive structures, while Transient Electromagnetic sounding (TEM) is very sensitive to conductive structures. Another difference is VES is better to detect shallow structures, while TEM soundings can reach deeper layers. A Matlab program for 1D joint inversion of VES and TEM soundings was developed aiming at exploring the best of both methods. The program uses CRS - Controlled Random Search - algorithm for both single and 1D joint inversions. Usually inversion programs use Marquadt type algorithms but for electrical and electromagnetic methods, these algorithms may find a local minimum or not converge. Initially, the algorithm was tested with synthetic data, and then it was used to invert experimental data from two places in Paraná sedimentary basin (Bebedouro and Pirassununga cities), both located in São Paulo State, Brazil. Geoelectric model obtained from VES and TEM data 1D joint inversion is similar to the real geological condition, and ambiguities were minimized. Results with synthetic and real data show that 1D VES/TEM joint inversion better recovers simulated models and shows a great potential in geological studies, especially in hydrogeological studies.

  8. Comparison between measured and predicted turbulence frequency spectra in ITG and TEM regimes

    Science.gov (United States)

    Citrin, J.; Arnichand, H.; Bernardo, J.; Bourdelle, C.; Garbet, X.; Jenko, F.; Hacquin, S.; Pueschel, M. J.; Sabot, R.

    2017-06-01

    The observation of distinct peaks in tokamak core reflectometry measurements—named quasi-coherent-modes (QCMs)—are identified as a signature of trapped-electron-mode (TEM) turbulence (Arnichand et al 2016 Plasma Phys. Control. Fusion 58 014037). This phenomenon is investigated with detailed linear and nonlinear gyrokinetic simulations using the Gene code. A Tore-Supra density scan is studied, which traverses through a linear (LOC) to saturated (SOC) ohmic confinement transition. The LOC and SOC phases are both simulated separately. In the LOC phase, where QCMs are observed, TEMs are robustly predicted unstable in linear studies. In the later SOC phase, where QCMs are no longer observed, ion-temperature-gradient (ITG) modes are identified. In nonlinear simulations, in the ITG (SOC) phase, a broadband spectrum is seen. In the TEM (LOC) phase, a clear emergence of a peak at the TEM frequencies is seen. This is due to reduced nonlinear frequency broadening of the underlying linear modes in the TEM regime compared with the ITG regime. A synthetic diagnostic of the nonlinearly simulated frequency spectra reproduces the features observed in the reflectometry measurements. These results support the identification of core QCMs as an experimental marker for TEM turbulence.

  9. Benchmarking of a novel contactless characterisation method for micro thermoelectric modules (μTEMs)

    International Nuclear Information System (INIS)

    Hickey, S; Punch, J; Jeffers, N

    2014-01-01

    Significant challenges exist in the thermal control of Photonics Integrated Circuits (PICs) for use in optical communications. Increasing component density coupled with greater functionality is leading to higher device-level heat fluxes, stretching the capabilities of conventional cooling methods using thermoelectric modules (TEMs). A tailored thermal control solution incorporating micro thermoelectric modules (μTEMs) to individually address hotspots within PICs could provide an energy efficient alternative to existing control methods. Performance characterisation is required to establish the suitability of commercially-available μTEMs for the operating conditions in current and next generation PICs. The objective of this paper is to outline a novel method for the characterisation of thermoelectric modules (TEMs), which utilises infra-red (IR) heat transfer and temperature measurement to obviate the need for mechanical stress on the upper surface of low compression tolerance (∼0.5N) μTEMs. The method is benchmarked using a commercially-available macro scale TEM, comparing experimental data to the manufacturer's performance data sheet.

  10. An efficient and reproducible process for transmission electron microscopy (TEM) of rare cell populations

    Science.gov (United States)

    Kumar, Sachin; Ciraolo, Georgianne; Hinge, Ashwini; Filippi, Marie-Dominique

    2014-01-01

    Transmission electron microscopy (TEM) provides ultra-structural details of cells at the sub-organelle level. However, details of the cellular ultrastructure, and the cellular organization and content of various organelles in rare populations, particularly in the suspension, like hematopoietic stem cells (HSCs) remained elusive. This is mainly due to the requirement of millions of cells for TEM studies. Thus, there is a vital requirement of a method that will allow TEM studies with low cell numbers of such rare populations. We describe an alternative and novel approach for TEM studies for rare cell populations. Here we performed TEM study from 10,000 HSC cells with quite ease. In particular, tiny cell pellets were identified by Evans blue staining after PFA-GA fixation. The cell pellet was pre-embedded in agarose in a small microcentrifuge tube and processed for dehydration, infiltration and embedding. Semi-thin and ultra-thin sections identified clusters of numerous cells per sections with well preserved morphology and ultrastructural details of golgi complex and mitochondria. Together, this method provides an efficient, easy and reproducible process to perform qualitative and quantitative TEM analysis from limited biological samples including cells in suspension. PMID:24291346

  11. Establishment of in situ TEM-implanter/accelerator interface facility at Wuhan University

    International Nuclear Information System (INIS)

    Guo, L.P.; Liu, C.S.; Li, M.; Song, B.; Ye, M.S.; Fu, D.J.; Fan, X.J.

    2008-01-01

    In order to perform in situ investigations on the evolution of microstructures during ion irradiation for the evaluation of irradiation-resistance performance of advanced materials, we have established a transmission electron microscope (TEM)-implanter/accelerator interface facility at Wuhan University, the first of its kind in China. A Hitachi H800 TEM was linked to a 200 kV ion implanter and a 2x1.7 MV tandem accelerator through the interface system designed on the basis of ion beam transportation calculations. Effective steps were taken to isolate the TEM from mechanical vibration transmitted from the ion beam lines, and no significant degradation of microscope resolution was observed when the TEM operated under high zoom modes during the ion implantation. In the test experiments, ion beams of N + , He + , Ar + , and H + were successfully transported from the implanter into the TEM chamber through the interface system, and the ion currents measured at the entrance of the TEM column were between 20 and 80 nA. The amorphisation process of Si crystal irradiated by N + ion beams was successfully observed in the preliminary experiments, demonstrating that this interface facility is capable of in situ study of ion irradiated samples

  12. ANALISIS PARAMETER JARINGAN HSDPA KONDISI INDOOR DENGAN TEMS INVESTIGATION DAN G-NETTRACK PRO

    Directory of Open Access Journals (Sweden)

    Dewa Made Mahendra Yudha

    2016-03-01

    Full Text Available Penggunaan teknologi dalam sistem komunikasi bergerak sudah berkembang cukup pesat. Salah satu contohnya ada teknologi HSDPA. Pihak provider biasanya melakukan metode walk test untuk mengecek kekuatan sinyal dengan menggunakan software TEMS Investigtions. Dengan kemajuannya Teknologi walk test dapat diterapkan dengan lebih mudah yaitu menggunakan perangkat android yang sudah terinstal aplikasi G-Net track Pro. Pada penelitian ini, akan menggunakan tahapan sesuai alur yang ada pada metode penelitian yaitu dimulai dengan melakukan pengukuran berdasarkan jarak dengan membandingkan software TEMS Investigations dan G-NET TRACK PRO dengan parameter RSCP dan Ec/No. Setelah dilakukan pengukuran kemudian akan dilanjutkan dengan menganalisa antara hubungan parameter RSCP dan Ec/No menggunakan TEMS Investigations dan G-Net Pro. kemudian dilanjutkan menggunakan perhitungan teoritis parameter RSCP. Dari hasil pengukuran diproleh pada lantai I antena 1-1 pada titik jarak 5 meter parameter RSCP dengan TEMS Investigation memiliki nilai -75 dBm sedangkan dari G-Net Track Pro memiliki nilai -83 dBm. Pada parameter Ec/No dengan TEMS Investigation memiliki nilai -6 dB dan G_Net Track memiliki nilai -5 dB. Dapat disimpulkan bahwa aplikasi G-NetTrack Pro mampu menampilkan parameter yang dibutuhkan akan tetapi tidak sedetail TEMS investigation sehingga untuk proses pembelajaran dan pengenalan walk test aplikasi G-Net track Pro dapat digunakan.

  13. Track Etch Membranes (TEMS) for separation sciences from BARC-TIFR Pelletron accelerator

    International Nuclear Information System (INIS)

    Nair, J.P.; Surendran, P.; Sparrow, Hillary; Gupta, A.K.; Kailas, S.; Bhagwat, P.V.

    2014-01-01

    TEMs are very much in need for the separation of desirable/undesirable metals from industrial effluents and radioactive wastes as well as in the field of biology and gas separation. It is necessary to optimize pore size and pore density for a specific application. TEMs available in market are imported and are used for laboratory scale activity. To carry the success of these activities on industrial scale large scale production of TEMs is needed. The availability of heavy ion accelerator made possible the production of TEMs in wide range of sizes. Many countries have set up facilities for continuous production of TEMs. BARC-TIFR Pelletron Accelerator at Mumbai delivers MeV energies of heavy ions for research in basic as well as applied sciences. Heavy ions of various species and energies from BARC-TIFR Pelletron Accelerator were used to make TEMs using polyethylene terephthalate (PET/Mylar) films of 25 micron thickness. The films used were procured from reputed manufactures in India

  14. Benchmarking of a novel contactless characterisation method for micro thermoelectric modules (μTEMs)

    Science.gov (United States)

    Hickey, S.; Punch, J.; Jeffers, N.

    2014-07-01

    Significant challenges exist in the thermal control of Photonics Integrated Circuits (PICs) for use in optical communications. Increasing component density coupled with greater functionality is leading to higher device-level heat fluxes, stretching the capabilities of conventional cooling methods using thermoelectric modules (TEMs). A tailored thermal control solution incorporating micro thermoelectric modules (μTEMs) to individually address hotspots within PICs could provide an energy efficient alternative to existing control methods. Performance characterisation is required to establish the suitability of commercially-available μTEMs for the operating conditions in current and next generation PICs. The objective of this paper is to outline a novel method for the characterisation of thermoelectric modules (TEMs), which utilises infra-red (IR) heat transfer and temperature measurement to obviate the need for mechanical stress on the upper surface of low compression tolerance (~0.5N) μTEMs. The method is benchmarked using a commercially-available macro scale TEM, comparing experimental data to the manufacturer's performance data sheet.

  15. Delayed formation of chromosome aberrations in mouse pachytebne spermatocytes treated with triethylenemelamine (TEM)

    International Nuclear Information System (INIS)

    Generoso, W.M.; Krishna, M.; Sotomayor, R.E.; Cacheiro, N.L.A.

    1977-01-01

    Induction of chromosome aberrations in pachytene spermatocytes of mice by 2 mg/kg TEM was compared with induction by 400 R x rays. These doses induced comparably high dominant lethal effects in pachytene spermatocytes of mice. Cytological analysis at diakinesis-metaphase I stage showed that whereas 76.4% of the cells treated with x rays at pachytene stage had aberrations, the frequencies observed in two TEM experiments were only 0.8 and 2.2%. On the other hand, 5% of the progeny from TEM-treated pachytene spermatocytes were found to be translocation heterozygotes. This is the first report on the recovery of heritable translocations from treated spermatocytes of mice. The aberration frequencies observed for TEM in diakinesis-metaphase I were much too low to account for all the lethal mutations and heritable translocations. Thus, the formation of the bulk of aberrations induced by TEM in pachytene spermatocytes was delayed--a marked contrast to the more immediate formation of x-ray-induced aberrations. It is postulated that the formation of the bulk of TEM-induced aberrations in pachytene spermatocytes and in certain postmeiotic stages occurs sometime during spermiogenesis, and not through the operation of postfertilization pronuclear DNA synthesis

  16. 'In situ' and 'Post-mortem' TEM study of the super-elastic effect in Cu-Al-Ni shape memory alloys

    International Nuclear Information System (INIS)

    Ibarra, A.; San Juan, J.; Bocanegra, E.H.; Caillard, D.; No, M.L.

    2006-01-01

    An analysis of the microstructure evolution during super-elastic cycling has been performed by transmission electron microscopy (TEM) in order to understand the physical mechanism responsible for the thermo-mechanical properties evolution, as well as the martensitic transformation ageing. Particularly, in this work we have studied the super-elastic effect in Cu-Al-Ni shape memory alloys by 'in situ' TEM experiments. The bright field images and diffraction patterns have allowed us to determine, during the transformation, the kind of nucleated martensite variants and their relative orientations. Finally, we have analysed the super-elastic effect on the dislocation microstructure and on the transformation temperatures

  17. Photoluminescence and TEM evaluations of defects generated during SiGe-on-insulator virtual substrate fabrication: Temperature ramping process

    International Nuclear Information System (INIS)

    Wang, D.; Ii, S.; Ikeda, K.; Nakashima, H.; Matsumoto, K.; Nakamae, M.; Nakashima, H.

    2006-01-01

    Crystal qualities were evaluated by photoluminescence (PL) and transmission electron microscopy (TEM) for cap-Si/SiGe/Si-on-insulater (SOI) structure, which is the typical structure for SiGe-on-insulator virtual substrate fabrication using the Ge condensation by dry oxidation. The thicknesses of cap-Si, SOI and BOX layers are 10, 70, and 140 nm, respectively. We have three kinds of wafers with SiGe thicknesses of 74, 154 and 234 nm. All of the wafers were heated from 200 deg.C to a target temperature (T t ) in the range of 820-1200 deg. C with a ramping rate of 5 deg. C/min, and maintained at T t for 10 min. The air in the furnace was a mixture of O 2 and N 2 . The PL measurements were carried out using a 325 nm UV line of a continuous-wave HeCd laser. Free exciton peaks were clearly observed for the as-grown wafers and decreased with an increase in the annealing temperature. For the selected wafers, cross-sectional and plan-view TEM measurements show clear generation and variation of dislocations at the interface of SiGe/SOI according to the T t . Defect-related PL signals were observed at around 0.82, 0.88, 0.95 and 1.0 eV, which also varied according to the T t and the SiGe thickness. They were identified to dislocation-related and stacking-fault-related defects by TEM

  18. Training in different brushing techniques in relation to efficacy of oral hygiene in young adults: a randomized controlled trial.

    Science.gov (United States)

    Harnacke, Daniela; Stein, Kathrin; Stein, Patrick; Margraf-Stiksrud, Jutta; Deinzer, Renate

    2016-01-01

    This study aims to assess plaque scores after oral hygiene in an unselected sample of young German adults and to compare the effects of computer-based training of the Fones versus the modified Bass technique on these scores. Seventy 18- to 19-year olds received computer-based training of the Fones technique, the modified Bass technique or basic instructions of oral hygiene alone (control group). The marginal plaque index (MPI; percentage of sections adjacent to the gingiva showing plaque) and BOP were assessed at baseline and after 6, 12 and 28 weeks. MPI was assessed immediately after participants had been asked to perform oral hygiene to the best of their abilities. At baseline, MPI levels of 83.3% ± 12.5 (mean ± SD) were observed. After 12 weeks, groups differed significantly (p group: 70.3% ± 14.7; Bass group: 77.91 ± 14.37; control group: 79.3% ± 9.2. No differences in BOP were found. High plaque levels at gingival margins after oral hygiene were observed in an unselected sample of young German adults. After 12 weeks, plaque levels after oral hygiene were slightly reduced in the group who had received training of the Fones technique but effects trailed off afterwards. The study failed to prove effects of the training on signs of gingival inflammation. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  19. Moessbauer and TEM study of martensitic transformations in ion implanted 17/7 stainless steel

    International Nuclear Information System (INIS)

    Johnson, E.; Johansen, A.; Sarholt-Kristensen, L.; Graabaek, L.

    1986-01-01

    It has earlier been shown that implantation of antimony into austenitic stainless steels induces martensitic phase transformations γ (fcc)→α (bcc). In the present work we have investigated which mechanisms are responsible for the transformation. Samples of 17/7 steels were implanted with noble gases (Kr, Ar) or the stainless steel constituent elements (Fe, Ni, Cr). The energies were selected to give ranges ∝40 nm. The phases present after implantation and the microstructures of the implanted samples were studied by CEMS and TEM respectively. A martensitic (α) phase was found to form after implantation both with Ni, Fe and Cr, in spite of the fact that these elements have opposite tendencies for stabilization of the austenite (γ) phase. The efficiency of martensite formation is therefore mainly related to stress relief associated with secondary radiation damage. This was substantiated from the noble gas implantations, where the highest degree of transformation was observed for fluences where bubble formation occurs. The CEMS analyses show that the transformation efficiency in such cases is nearly 100%. The hyperfine parameters of the implantation induced α phase are similar to those from conventionally induced martensites. (orig.)

  20. Cardiopulmonary resuscitation (CPR)-related posterior rib fractures in neonates and infants following recommended changes in CPR techniques.

    Science.gov (United States)

    Franke, I; Pingen, A; Schiffmann, H; Vogel, M; Vlajnic, D; Ganschow, R; Born, M

    2014-07-01

    Posterior rib fractures are highly indicative of non-accidental trauma (NAT) in infants. Since 2000, the "two-thumbs" technique for cardiopulmonary resuscitation (CPR) of newborns and infants has been recommended by the American Heart Association (AHA). This technique is similar to the grip on an infant's thorax while shaking. Is it possible that posterior rib fractures in newborns and infants could be caused by the "two-thumbs" technique? Using computerized databases from three German children's hospitals, we identified all infants less than 12 months old who underwent professional CPR within a 10-year period. We included all infants with anterior-posterior chest radiographs taken after CPR. Exclusion criteria were sternotomy, osteopenia, various other bone diseases and NAT. The radiographs were independently reviewed by the Chief of Pediatric Radiology (MB) and a Senior Pediatrician, Head of the local Child Protection Team (IF). Eighty infants with 546 chest radiographs were identified, and 50 of those infants underwent CPR immediately after birth. Data concerning the length of CPR was available for 41 infants. The mean length of CPR was 11min (range: 1-180min, median: 3min). On average, there were seven radiographs per infant. A total of 39 infants had a follow-up radiograph after at least 10 days. No rib fracture was visible on any chest X-ray. The results of this study suggest rib fracture after the use of the "two-thumbs" CPR technique is uncommon. Thus, there should be careful consideration of abuse when these fractures are identified, regardless of whether CPR was performed and what technique used. The discovery of rib fractures in an infant who has undergone CPR without underlying bone disease or major trauma warrants a full child protection investigation. Copyright © 2014 Elsevier Ltd. All rights reserved.

  1. A comparison of EDS microanalysis in FIB-prepared and electropolished TEM thin foils

    International Nuclear Information System (INIS)

    Hutchinson, C.R.; Hackenberg, R.E.; Shiflet, G.J.

    2003-01-01

    This paper reports the results of a fine-probe EDS microanalytical study of cellular precipitation in a Cu-Ti binary alloy. Compositional profiles across the solute depleted Cu-rich FCC lamellae and the Cu 4 Ti lamellae within isothermally formed cellular colonies were measured in a FEG-TEM from thin-foil specimens prepared by conventional electropolishing and by a technique using a Ga + focused ion-beam (FIB). The Cliff-Lorimer ratio method, with an absorption correction, was employed to quantify the compositions. Two FIB samples were prepared with different orientations of the lamellae with respect to the ion-milling direction. The compositional profiles across the Cu-rich FCC lamellae and the Cu 4 Ti compound lamellae in both the FIB-prepared samples and the electropolished sample were, within experimental error, numerically equivalent. The composition of the Cu 4 Ti compound phase lamellae was very close to the ideal stoichiometric composition of 20 at% Ti. It is concluded that for this system, and for the specimen preparation procedures used in this study, the Ga + ion-milling process has had no detectable effect on the chemistry changes across the interlamellar interface at the scale studied. These results indicate that the possible sources of chemical artifacts which include redeposition, preferential sputtering and ion-induced atomic migration can be minimized if several precautions are taken during milling in the FIB. Consistent with previous investigators, it was also found that the ion-milling process does introduce significant structural artifacts (e.g., dislocations) into the softer FCC Cu-rich phase compared with a specimen produced by conventional electropolishing

  2. Shallow groundwater investigation using time-domain electromagnetic (TEM) method at Itay El-Baroud, Nile Delta, Egypt

    Science.gov (United States)

    Shaaban, H.; El-Qady, G.; Al-Sayed, E.; Ghazala, H.; Taha, A. I.

    2016-12-01

    The Nile Delta is one of the oldest known ancient delta, largest and most important depositional complex in the Mediterranean sedimentary basin. Furthermore, it is a unique site in Egypt that is suitable for accumulation and preservation of the Quaternary sediments. In this work we applied time-domain electromagnetic (TEM) method to investigate the Quaternary sediments sequence as well as detecting the groundwater aquifer in the area of study. A suite of 232 TEM sounding at 43 stations were carried out using a ;SIROTEM MK-3; time-domain electromagnetic system. A simple coincident loop configuration, in which the same loop transmits and receives signals, was employed with loop side length of 25 m. The 1-D modeling technique was applied to estimate the depth and the apparent resistivity of the interpreted geoelectrical data. Based on the interpretation of the acquired geophysical data, four geoelectric cross-sections were constructed. These sections show that the Upper Quaternary sequence consists of three geoelectric layers. The Holocene Nile mud is separated into two layers: the agricultural root zone (Layer 1) and thick water saturated mud (Layer 2). The Upper Pleistocene sandy aquifer (Layer 3) is very complicated non-linear boundary. This aquifer is the most important unit since it is considered as the main water bearing unit in the study area.

  3. Comparison of ultramicrotomy and focused-ion-beam for the preparation of TEM and STEM cross section of organic solar cells

    Energy Technology Data Exchange (ETDEWEB)

    Corazza, Michael, E-mail: michael.corazza@gmail.com [Department of Energy Conversion and Storage, Technical University of Denmark, Frederiksborgvej 399, 4000 Roskilde (Denmark); Simonsen, Søren B. [Department of Energy Conversion and Storage, Technical University of Denmark, Frederiksborgvej 399, 4000 Roskilde (Denmark); Gnaegi, Helmut [Diatome Ltd., Biel-Bienne (Switzerland); Thydén, Karl T.S.; Krebs, Frederik C.; Gevorgyan, Suren A. [Department of Energy Conversion and Storage, Technical University of Denmark, Frederiksborgvej 399, 4000 Roskilde (Denmark)

    2016-12-15

    Highlights: • Comparison of flexible solar cell sections prepared by ultramicrotomy and by FIB. • Energy filtered TEM analysis of phase separation in the P3HT:PCBM active layer. • Imaging of aging effects on solar cell cross section prepared by ultramicrotomy. • Ultramicrotomy provides great details while FIB better preserves the structure. - Abstract: The challenge of preparing cross sections of organic photovoltaics (OPV) suitable for transmission electron microscopy (TEM) and scanning TEM (STEM) is addressed. The samples were polymer solar cells fabricated using roll-to-roll (R2R) processing methods on a flexible polyethylene terephthalate (PET) substrate. Focused ion beam (FIB) and ultramicrotomy were used to prepare the cross sections. The differences between the samples prepared by ultramicrotomy and FIB are addressed, focusing on the advantages and disadvantages of each technique. The sample prepared by ultramicrotomy yielded good resolution, enabling further studies of phase separation of P3HT:PCBM by means of energy filtered TEM (EFTEM). The sample prepared by FIB shows good structure preservation, but reduced resolution due to non-optimal thicknesses achieved after treatment. Degradation studies of samples prepared by ultramicrotomy are further discussed, which reveal particular effects of the ISOS-L-3 aging test (85 °C, 50% R.H., 0.7 Sun) onto the sample, especially pronounced in the silver layer.

  4. Generation of a microelectron beam by an intense short pulse laser in the TEM(1, 0) + TEM(0, 1) mode in vacuum

    International Nuclear Information System (INIS)

    Miyazaki, Shuji; Kawata, Shigeo; Kong, Qing; Miyauchi, Koichi; Sakai, Kei; Hasumi, Shotaro; Sonobe, Ryo; Kikuchi, Takashi

    2005-01-01

    The generation of a high energy microelectron bunch in vacuum by an intense short pulse laser in the TEM(1, 0) + TEM(0, 1) mode is investigated in this paper numerically and analytically. A focused short pulse laser in the TEM(1, 0) + TEM(0, 1) mode has a confinement effect on electrons in the transverse direction due to the transverse ponderomotive force, and at the same time the electrons are accelerated and compressed longitudinally by a longitudinal electric field. In our three-dimensional particle simulations, the maximum kinetic energy of electrons reaches 455 MeV, the maximum density is 3.87 x 10 10 cm -3 , and the normalized transverse and longitudinal rms emittances of accelerated electrons are of the order of 10 -6 m rad at the following parameter values: a 0 = eE 0 /(m e ω c) = 10 (where a 0 is the dimensionless parameter of the laser amplitude, e and m e are the electron charge and rest mass, respectively, E 0 is the laser amplitude, ω the angular frequency of the laser and c the speed of light in vacuum), a laser wavelength λ = 0.8 μm, laser spot size 20λ, laser pulse length 5λ and initial electron velocity 0.99c. Moreover, the transverse and longitudinal sizes of the compressed electron bunch are about 600λ and 10λ, respectively. In this paper, we also present a scaling law of the maximum electron energy. The estimated results of the maximum electron energy coincide well with the simulation results

  5. In situ TEM and synchrotron characterization of U–10Mo thin specimen annealed at the fast reactor temperature regime

    International Nuclear Information System (INIS)

    Yun, Di; Mo, Kun; Mohamed, Walid; Ye, Bei; Kirk, Marquis A.; Baldo, Peter; Xu, Ruqing; Yacout, Abdellatif M.

    2015-01-01

    U–Mo metallic alloys have been extensively used for the Reduced Enrichment for Research and Test Reactors (RERTR) program, which is now known as the Office of Material Management and Minimization under the Conversion Program. This fuel form has also recently been proposed as fast reactor metallic fuels in the recent DOE Ultra-high Burnup Fast Reactor project. In order to better understand the behavior of U–10Mo fuels within the fast reactor temperature regime, a series of annealing and characterization experiments have been performed. Annealing experiments were performed in situ at the Intermediate Voltage Electron Microscope (IVEM-Tandem) facility at Argonne National Laboratory (ANL). An electro-polished U–10Mo alloy fuel specimen was annealed in situ up to 700 °C. At an elevated temperature of about 540 °C, the U–10Mo specimen underwent a relatively slow microstructure transition. Nano-sized grains were observed to emerge near the surface. At the end temperature of 700 °C, the near-surface microstructure had evolved to a nano-crystalline state. In order to clarify the nature of the observed microstructure, Laue diffraction and powder diffraction experiments were carried out at beam line 34-ID of the Advanced Photon Source (APS) at ANL. Phases present in the as-annealed specimen were identified with both Laue diffraction and powder diffraction techniques. The U–10Mo was found to recrystallize due to thermally-induced recrystallization driven by a high density of pre-existing dislocations. A separate in situ annealing experiment was carried out with a Focused Ion Beam processed (FIB) specimen. A similar microstructure transition occurred at a lower temperature of about 460 °C with a much faster transition rate compared to the electro-polished specimen. - Highlights: • TEM annealing experiments were performed in situ at the IVEM facility up to fast reactor temperature. • At 540 °C, the U-10Mo specimen underwent a slow microstructure transition

  6. In situ TEM and synchrotron characterization of U–10Mo thin specimen annealed at the fast reactor temperature regime

    Energy Technology Data Exchange (ETDEWEB)

    Yun, Di, E-mail: diyun1979@xjtu.edu.cn [Argonne National Laboratory, 9700 South Cass Avenue, Argonne, IL 60439 (United States); Xi' an Jiao Tong University, 28 Xian Ning West Road, Xi' an 710049 (China); Mo, Kun; Mohamed, Walid; Ye, Bei; Kirk, Marquis A.; Baldo, Peter; Xu, Ruqing; Yacout, Abdellatif M. [Argonne National Laboratory, 9700 South Cass Avenue, Argonne, IL 60439 (United States)

    2015-12-15

    U–Mo metallic alloys have been extensively used for the Reduced Enrichment for Research and Test Reactors (RERTR) program, which is now known as the Office of Material Management and Minimization under the Conversion Program. This fuel form has also recently been proposed as fast reactor metallic fuels in the recent DOE Ultra-high Burnup Fast Reactor project. In order to better understand the behavior of U–10Mo fuels within the fast reactor temperature regime, a series of annealing and characterization experiments have been performed. Annealing experiments were performed in situ at the Intermediate Voltage Electron Microscope (IVEM-Tandem) facility at Argonne National Laboratory (ANL). An electro-polished U–10Mo alloy fuel specimen was annealed in situ up to 700 °C. At an elevated temperature of about 540 °C, the U–10Mo specimen underwent a relatively slow microstructure transition. Nano-sized grains were observed to emerge near the surface. At the end temperature of 700 °C, the near-surface microstructure had evolved to a nano-crystalline state. In order to clarify the nature of the observed microstructure, Laue diffraction and powder diffraction experiments were carried out at beam line 34-ID of the Advanced Photon Source (APS) at ANL. Phases present in the as-annealed specimen were identified with both Laue diffraction and powder diffraction techniques. The U–10Mo was found to recrystallize due to thermally-induced recrystallization driven by a high density of pre-existing dislocations. A separate in situ annealing experiment was carried out with a Focused Ion Beam processed (FIB) specimen. A similar microstructure transition occurred at a lower temperature of about 460 °C with a much faster transition rate compared to the electro-polished specimen. - Highlights: • TEM annealing experiments were performed in situ at the IVEM facility up to fast reactor temperature. • At 540 °C, the U-10Mo specimen underwent a slow microstructure transition

  7. A study on effects of size and structure on hygroscopicity of nanoparticles using a tandem differential mobility analyzer and TEM

    Energy Technology Data Exchange (ETDEWEB)

    Park, Kihong, E-mail: kpark@gist.ac.kr; Kim, Jae-Seok [Gwangju Institute of Science and Technology (GIST), Research Center for Biomolecular Nanotechnology, Department of Environmental Science and Engineering (Korea, Republic of); Miller, Arthur L. [National Institute for Occupational Safety and Health/Spokane Research Lab (United States)

    2009-01-15

    A hygroscopicity tandem differential mobility analyzer (HTDMA) technique is used to determine size-effect of nanoparticles (NaCl, (NH{sub 4}){sub 2}SO{sub 4}, KCl, NH{sub 4}NO{sub 3}, MgCl{sub 2}, CaCl{sub 2}) on their hygroscopic properties (deliquescence relative humidity (DRH) and hygroscopic growth factor (GF)). The HTDMA system uses a combination of two nano DMAs and two regular DMAs to measure particle size change in a wide dynamic particle size range. Particles are subsequently analyzed with a transmission electron microscopy to investigate the potential effect of particle structure or morphology on the hygroscopic properties. We found that structural properties of NaCl and (NH{sub 4}){sub 2}SO{sub 4} particles also play an important role in determination of the DRH and GF and are more pronounced at smaller diameters. Data show that the DRH of NaCl nanoparticles increased from {approx}75% up to {approx}83% RH at 8 nm and that their GF decreased with decreasing size. The extent to which the GF of NaCl nanoparticles decreased with decreasing size was greater than theoretically predicted with the Kelvin correction. The GF of furnace-generated NaCl nanoparticles that have pores and aggregate shape was found to be smaller than that of atomizer-generated particles that are close to perfectly cubic. For the case of atomizer-generated (NH{sub 4}){sub 2}SO{sub 4} nanoparticles, we observed no significant size-effect on their DRH, and the measured GF agreed well with predicted values using the Kelvin correction. For furnace-generated (NH{sub 4}){sub 2}SO{sub 4} nanoparticles, a gradual growth at moderate RH without noticeable deliquescence behavior occurred. Their TEM images showed that contrary to atomizer-generated (NH{sub 4}){sub 2}SO{sub 4} nanoparticles the furnace-generated (NH{sub 4}){sub 2}SO{sub 4} nanoparticles are not perfectly spherical and are often aggregates having pores and holes, which may favor holding residual water even in the dried condition. For

  8. Introducing the event related fixed interval area (ERFIA) multilevel technique: a method to analyze the complete epoch of event-related potentials at single trial level

    NARCIS (Netherlands)

    Vossen, C.J.; Vossen, H.G.M.; Marcus, M.A.E.; van Os, J.; Lousberg, R.

    2013-01-01

    In analyzing time-locked event-related potentials (ERPs), many studies have focused on specific peaks and their differences between experimental conditions. In theory, each latency point after a stimulus contains potentially meaningful information, regardless of whether it is peak-related. Based on

  9. Integrated model for providing tactical emergency medicine support (TEMS): analysis of 120 tactical situations.

    Science.gov (United States)

    Vainionpää, T; Peräjoki, K; Hiltunen, T; Porthan, K; Taskinen, A; Boyd, J; Kuisma, M

    2012-02-01

    Various models for organising tactical emergency medicine support (TEMS) in law enforcement operations exist. In Helsinki, TEMS is organised as an integral part of emergency medical service (EMS) and applied in hostage, siege, bomb threat and crowd control situations and in other tactical situations after police request. Our aim was to analyse TEMS operations, patient profile, and the level of on-site care provided. We conducted a retrospective cohort study of TEMS operations in Helsinki from 2004 to 2009. Data were retrieved from EMS, hospital and dispatching centre files and from TEMS reports. One hundred twenty TEMS operations were analysed. Median time from dispatching to arrival on scene was 10 min [Interquartile Range (IQR) 7-14]. Median duration of operations was 41 min (IQR 19-63). Standby was the only activity in 72 operations, four patients were dead on arrival, 16 requests were called off en route and patient examination or care was needed in 28 operations. Twenty-eight patients (records retrieved) were alive on arrival and were classified as trauma (n = 12) or medical (n = 16). Of traumas, two sustained a gunshot wound, one sustained a penetrating abdominal wound, three sustained medium severity injuries and nine sustained minor injuries. There was neither on-scene nor in-hospital mortality among patients who were alive on arrival. The level of on-site care performed was basic life support in all cases. The results showed that TEMS integrated to daily EMS services including safe zone working only was a feasible, rapid and efficient way to provide medical support to law enforcement operations. © 2011 The Authors Acta Anaesthesiologica Scandinavica © 2011 The Acta Anaesthesiologica Scandinavica Foundation.

  10. Moessbauer, TEM/SAED and XRD investigation on waste dumps of the Valea lui Stan gold mines

    Energy Technology Data Exchange (ETDEWEB)

    Constantinescu, Serban Grigore, E-mail: sconst@infim.ro [National Institute of Materials Physics, Bucharest-Magurele (Romania); Udubasa, Sorin S.; Udubasa, Gheorghe [University of Bucharest, Fac. of Geology and Geophysics (Romania); Kuncser, Victor; Popescu-Pogrion, Nicoleta; Mercioniu, Ionel; Feder, Marcel [National Institute of Materials Physics, Bucharest-Magurele (Romania)

    2012-03-15

    The complementary investigation techniques, Moessbauer spectroscopy, transmission electron microscopy with selected area electron diffraction (TEM/SAED), X-ray diffraction (XRD) have been used to investigate the fate of the Valea lui Stan, Romania, gold-ore nanoscale-minerals during the long time of residence in the waste dumps. The preliminary investigations showed such waste dumps to contain significant amount of metals which cannot be identified by conventional methods. An intense research activity started up in order to evaluate the possibilities to recycle Valea lui Stan waste dumps and to recover metals by chemical or phytoextraction procedures. The waste dumps naturally show different mineral constituents with clay minerals as major phases, observed by XRD-technique. Although the waste dumps materials have whitish-yellowish colours, MOeSSBAUER technique evidences the presence of the finely dispersed iron bearing minerals. The authors are focusing to inspect and analyze Fe-compounds in the samples collected from Valea lui Stan's waste dumps in order to identify the magnetic phases by Moessbauer technique.

  11. SEM and TEM Characterization of As-Fabricated U-7Mo Disperson Fuel Plates

    International Nuclear Information System (INIS)

    Keiser, D.D. Jr.; Yao, B.; Perez, E.; Sohn, Y.H.

    2009-01-01

    The starting microstructure of a dispersion fuel plate can have a dramatic impact on the overall performance of the plate during irradiation. To improve the understanding of the as-fabricated microstructures of dispersion fuel plates, SEM and TEM analysis have been performed on RERTR-9A archive fuel plates, which went through an additional hot isostatic procsssing (HIP) step during fabrication. The fuel plates had depleted U-7Mo fuel particles dispersed in either Al-2Si or 4043 Al alloy matrix. For the characterized samples, it was observed that a large fraction of the ?-phase U-7Mo alloy particles had decomposed during fabrication, and in areas near the fuel/matrix interface where the transformation products were present significant fuel/matrix interaction had occurred. Relatively thin Si-rich interaction layers were also observed around the U-7Mo particles. In the thick interaction layers, (U)(Al,Si)3 and U6Mo4Al43 were identified, and in the thin interaction layers U(Al,Si)3, U3Si3Al2, U3Si5, and USi1.88-type phases were observed. The U3Si3Al2 phase contained some Mo. Based on the results of this work, exposure of dispersion fuel plates to relatively high temperatures during fabrication impacts the overall microstructure, particularly the nature of the interaction layers around the fuel particles. The time and temperature of fabrication should be carefully controlled in order to produce the most uniform Si-rich layers around the U-7Mo particles.

  12. Challenges in quantitative crystallographic characterization of 3D thin films by ACOM-TEM

    Energy Technology Data Exchange (ETDEWEB)

    Kobler, A. [Institute of Nanotechnology (INT), Karlsruhe Institute of Technology (KIT), Hermann-von-Helmholtz-Platz 1, 76344, Eggenstein-Leopoldshafen (Germany); Karlsruhe Nano Micro Facility (KNMF), Karlsruhe Institute of Technology (KIT), Hermann-von-Helmholtz-Platz 1, 76344, Eggenstein-Leopoldshafen (Germany); Kübel, C., E-mail: christian.kuebel@kit.edu [Institute of Nanotechnology (INT), Karlsruhe Institute of Technology (KIT), Hermann-von-Helmholtz-Platz 1, 76344, Eggenstein-Leopoldshafen (Germany); Karlsruhe Nano Micro Facility (KNMF), Karlsruhe Institute of Technology (KIT), Hermann-von-Helmholtz-Platz 1, 76344, Eggenstein-Leopoldshafen (Germany)

    2017-02-15

    Automated crystal orientation mapping for transmission electron microscopy (ACOM-TEM) has become an easy to use method for the investigation of crystalline materials and complements other TEM methods by adding local crystallographic information over large areas. It fills the gap between high resolution electron microscopy and electron back scatter diffraction in terms of spatial resolution. Recent investigations showed that spot diffraction ACOM-TEM is a quantitative method with respect to sample parameters like grain size, twin density, orientation density and others. It can even be used in combination with in-situ tensile or thermal testing. However, there are limitations of the current method. In this paper we discuss some of the challenges and discuss solutions, e.g. we present an ambiguity filter that reduces the number of pixels with a ‘180° ambiguity problem’. For that an ACOM-TEM tilt series of nanocrystalline Pd thin films with overlapping crystallites was acquired and analyzed. - Highlights: • Tilt series of nanocrystalline Pd thin films. • Quantitative ACOM-TEM data processing, including a rotation map of crystallites. • Noise filter for orientation data: Ambiguity Filter and min. distance filter.

  13. Minimum depth of investigation for grounded-wire TEM due to self-transients

    Science.gov (United States)

    Zhou, Nannan; Xue, Guoqiang

    2018-05-01

    The grounded-wire transient electromagnetic method (TEM) has been widely used for near-surface metalliferous prospecting, oil and gas exploration, and hydrogeological surveying in the subsurface. However, it is commonly observed that such TEM signal is contaminated by the self-transient process occurred at the early stage of data acquisition. Correspondingly, there exists a minimum depth of investigation, above which the observed signal is not applicable for reliable data processing and interpretation. Therefore, for achieving a more comprehensive understanding of the TEM method, it is necessary to perform research on the self-transient process and moreover develop an approach for quantifying the minimum detection depth. In this paper, we first analyze the temporal procedure of the equivalent circuit of the TEM method and present a theoretical equation for estimating the self-induction voltage based on the inductor of the transmitting wire. Then, numerical modeling is applied for building the relationship between the minimum depth of investigation and various properties, including resistivity of the earth, offset, and source length. It is guide for the design of survey parameters when the grounded-wire TEM is applied to the shallow detection. Finally, it is verified through applications to a coal field in China.

  14. Structure and Output Characteristics of a TEM Array Fitted to a Fin Heat Exchanger

    Science.gov (United States)

    Zhang, Z.; Chen, L. N.; Chen, Z. J.; Xiao, G. Q.; Liu, Z. J.

    2015-06-01

    In the design of a thermoelectric generator, both the heat transfer area and the number of thermoelectric modules (TEMs) should be increased accordingly as the generator power increases; crucially, both aspects need to be coordinated. A kilowatt thermoelectric generator with a fin heat exchanger is proposed for use in a constant-speed diesel generator unit. Interior fins enhance convective heat transfer, whereas an exterior fin segment increases the heat transfer area. The heat transfer surface is double that of a plane heat exchanger, and the temperature field over the exterior fins is constrained to a one-dimensional distribution. Between adjoining exterior fins, there is a cooling water channel with trapezoid cross-section, enabling compact TEMs and cooling them. Hence, more TEMs are built as a series-parallel array of TEMs with lower resistance and more stable output current. Under nonuniform conditions, to prevent circulation and energy loss, bypass diodes and antidiodes are added. Experiments and numerical calculations show that, with matching and optimization of the heat exchanger and TEM array, a stable maximum output power is obtainable from the interior of the thermoelectric generator system, which can be connected to an external maximum power point tracking system.

  15. A preliminary study of CdS for solar cells using combined TEM and cathodoluminescence

    International Nuclear Information System (INIS)

    Mam, K.; Durose, K.; Halliday, D.P.; Szczerbakow, A.

    2005-01-01

    A study of the suitability of a combined transmission electron microscope (TEM)/cathodoluminescence (CL) imaging and spectroscopy apparatus for investigations of CdS is presented. Photoluminescence (PL) was used to evaluate the effect of the Ar + and I + ion beam thinning used in TEM specimen preparation of CdS: a minor increase in yellow emission (594 nm) resulted. However, excitation of luminescence spectra in the TEM had a quenching effect on red luminescence (734 nm), this being considered due to the high excitation density compared to that in PL. Significant electron beam damage to the CdS could be avoided by using scanning transmission electron microscope (STEM) illumination in preference to the conventional TEM mode, which generally uses higher beam current density. Dislocation images were correlated with contrast in the STEM-CL imaging mode. The potential of the apparatus to make further direct correlations of CL images with diffraction contrast TEM imaging was assessed using the Rose visibility criterion

  16. Evaluating the effectiveness of behavior change techniques in health-related behavior: a scoping review of methods used.

    Science.gov (United States)

    Michie, Susan; West, Robert; Sheals, Kate; Godinho, Cristina A

    2018-03-01

    Behavior change interventions typically contain multiple potentially active components: behavior change techniques (BCTs). Identifying which specific BCTs or BCT combinations have the potential to be effective for a given behavior in a given context presents a major challenge. The aim of this study was to review the methods that have been used to identify effective BCTs for given behaviors in given contexts and evaluate their strengths and limitations. A scoping review was conducted of studies that had sought to identify effective BCTs. Articles referring to "behavio(u)r change technique(s)" in the abstract/text were located, and ones that involved identification of effective BCTs were selected. The methods reported were coded. The methods were analyzed in general terms using "PASS" criteria: Practicability (facility to apply the method appropriately), Applicability (facility to generalize from findings to contexts and populations of interest), Sensitivity (facility to identify effective BCTs), and Specificity (facility to rule out ineffective BCTs). A sample of 10% of the studies reviewed was then evaluated using these criteria to assess how far the strengths and limitations identified in principle were borne out in practice. One hundred and thirty-five studies were identified. The methods used in those studies were experimental manipulation of BCTs, observational studies comparing outcomes in the presence or absence of BCTs, meta-analyses of BCT comparisons, meta-regressions evaluating effect sizes with and without specific BCTs, reviews of BCTs found in effective interventions, and meta-classification and regression trees. The limitations of each method meant that only weak conclusions could be drawn regarding the effectiveness of specific BCTs or BCT combinations. Methods for identifying effective BCTs linked to target behavior and context all have important inherent limitations. A strategy needs to be developed that can systematically combine the strengths of

  17. Public Relations Techniques for Leaders in a Crisis: Mackenzie King and John Curtin in the Canadian-Australian War Alliance, 1941-1945

    Directory of Open Access Journals (Sweden)

    Caryn Coatney

    2012-12-01

    Full Text Available During their Pacific war alliance, the Canadian and Australian prime ministers initiated public relations techniques that secured journalists’ support, providing insights for developing positive media relations in the contemporary global financial crisis. As popular leaders, Canada’s Mackenzie King and Australia’s John Curtin used their backgrounds in news management and journalism to set precedents in government-media interactions. Yet there has been a lack of publications on their success as public relations strategists to persuade journalists and citizens to endorse their leadership in this alliance. King and Curtin advanced the use of relatively new media to convey symbolic messages that they were trustworthy leaders, sharing similar values and challenges as working-class audiences. Their expansion of the prime minister’s traditional use of the press, radio, and newsreel films created more opportunities for citizens to engage with political leaders and the government. By initiating more two-way discussions with journalists, they generated mainly favourable news coverage about their alliance. This paper investigates their use of interactive news interviews, practiced rhetoric, rehearsed gestures, expressions, and other media techniques to communicate with more citizens, based on the concepts of the public sphere and democratic governance developed by Habermas and Castells. Their techniques aided the development of more contemporary public relations practices in Canada and Australia. These tactics are relevant for today’s leaders when interacting with public audiences in diverse media to develop a shared understanding of common goals to resolve the global financial crisis.

  18. Applying the nominal group technique in an employment relations conflict situation: A case study of a university maintenance section in South Africa

    Directory of Open Access Journals (Sweden)

    Cornelis (Kees S. van der Waal

    2009-09-01

    Full Text Available After a breakdown in employment relations in the maintenance section of a higher education institution, the authors were asked to intervene in order to try and solve the employment relations conflict situation. It was decided to employ the Nominal Group Technique (NGT as a tool in problem identification during conflict in the workplace. An initial investigation of documentation and interviews with prominent individuals in the organisation was carried out. The NGT was then used in four focus group discussions to determine the important issues as seen by staff members. The NGT facilitates the determination of shared perceptions and the ranking of ideas. The NGT was used in diverse groups, necessitating adaptations to the technique. The perceived causes of the conflict were established. The NGT can be used in a conflict situation in the workplace in order to establish the perceived causes of employment relations conflict.

  19. An Assessment of Polynomial Regression Techniques for the Relative Radiometric Normalization (RRN of High-Resolution Multi-Temporal Airborne Thermal Infrared (TIR Imagery

    Directory of Open Access Journals (Sweden)

    Mir Mustafizur Rahman

    2014-11-01

    Full Text Available Thermal Infrared (TIR remote sensing images of urban environments are increasingly available from airborne and satellite platforms. However, limited access to high-spatial resolution (H-res: ~1 m TIR satellite images requires the use of TIR airborne sensors for mapping large complex urban surfaces, especially at micro-scales. A critical limitation of such H-res mapping is the need to acquire a large scene composed of multiple flight lines and mosaic them together. This results in the same scene components (e.g., roads, buildings, green space and water exhibiting different temperatures in different flight lines. To mitigate these effects, linear relative radiometric normalization (RRN techniques are often applied. However, the Earth’s surface is composed of features whose thermal behaviour is characterized by complexity and non-linearity. Therefore, we hypothesize that non-linear RRN techniques should demonstrate increased radiometric agreement over similar linear techniques. To test this hypothesis, this paper evaluates four (linear and non-linear RRN techniques, including: (i histogram matching (HM; (ii pseudo-invariant feature-based polynomial regression (PIF_Poly; (iii no-change stratified random sample-based linear regression (NCSRS_Lin; and (iv no-change stratified random sample-based polynomial regression (NCSRS_Poly; two of which (ii and iv are newly proposed non-linear techniques. When applied over two adjacent flight lines (~70 km2 of TABI-1800 airborne data, visual and statistical results show that both new non-linear techniques improved radiometric agreement over the previously evaluated linear techniques, with the new fully-automated method, NCSRS-based polynomial regression, providing the highest improvement in radiometric agreement between the master and the slave images, at ~56%. This is ~5% higher than the best previously evaluated linear technique (NCSRS-based linear regression.

  20. Measuring fusion excitation functions with RIBs: A thorough analysis of the stacked target technique and the related problems

    International Nuclear Information System (INIS)

    Fisichella, M.; Di Pietro, A.; Figuera, P.; Marchetta, C.; Shotter, A. C.; Lattuada, M.; Torresi, D.; Privitera, V.; Romano, L.; Ruiz, C.; Zadro, M.

    2015-01-01

    The use of the stacked target technique to measure fusion cross-sections of reactions induced by low intensity radioactive beams offers considerable advantages since several reaction energies may be simultaneously measured. The main disadvantage of the method is the degradation of the beam quality as it passes through the stack due to statistical nature of energy loss processes and any non-uniformity of the stacked targets. This degradation can lead to ambiguities of associating effective beam energies to reaction product yields for the targets within the stack. A detailed investigation of these ambiguities has been performed and some of the obtained results are presented

  1. In vitro manipulation techniques of porcine embryos: a meta-analysis related to transfers, pregnancies and piglets.

    Science.gov (United States)

    Liu, Ying; Li, Juan; Løvendahl, Peter; Schmidt, Mette; Larsen, Knud; Callesen, Henrik

    2015-03-01

    During the last 17 years, considerable advancements have been achieved in the production of pigs, transgenic and non-transgenic, by methods of somatic cell nuclear transfer, in vitro fertilisation, intracytoplasmic sperm injection, microinjection and sperm-mediated gene transfer by artificial insemination. Therefore, a review of the overall efficiency for the developmental competence of embryos produced by these in vitro methods would be useful in order to obtain a more thorough overview of this growing area with respect to its development and present status. In this review a meta-analysis was used to analyse data collected from all published articles with a focus on zygotes and embryos for transfer, pregnancy, full-term development and piglets born. It was generally concluded that an increasing level of in vitro manipulation of porcine embryos decreased the overall efficiency for production of piglets. The techniques of nuclear transfer have been developed markedly through the increasing number of studies performed, and the results have become more stable. Prolonged in vitro culture period did not lead to any negative effect on nuclear transfer embryos after their transfer and it resulted in a similar or even higher litter size. More complete information is needed in future scientific articles about these in vitro manipulation techniques to establish a more solid basis for the evaluation of their status and to reveal and further investigate any eventual problems.

  2. Formation and properties of epitaxial CdSe, ZnSe quantum dots. Conventional molecular beam epitaxy and related techniques

    Energy Technology Data Exchange (ETDEWEB)

    Mahapatra, Suddhasatta

    2008-01-16

    This thesis systematically investigates three such alternative approaches, along with conventional MBE, with emphasis on the formation-mechanism of QDs, and optimization of their morphological and optical attributes. it is shown here that no distinct 3D islands are formed in MBE growth of CdSe on ZnSe. While CdSe heteroepitaxy occurs in the multilayer-mode at T{sub G}=300 C, a reentrant recovery of the layer-by-layer mode is reported in this thesis, for growth at T{sub G}<{proportional_to}240 C. In the second variant technique, formation of large and distinct islands is demonstrated by deposition of amorphous selenium (a-Se) onto a 2D CdSe epilayer at room temperature and its subsequent desorption at a higher temperature (T{sub D}=230 C). The process steps of the third variant technique, developed in course of this work, are very similar to those of the previous one-the only alteration being the substitution of selenium with tellurium as the cap-forming-material. (orig.)

  3. Dissecting functions of the retinoblastoma tumor suppressor and the related pocket proteins by integrating genetic, cell biology, and electrophoretic techniques

    DEFF Research Database (Denmark)

    Hansen, Klaus; Lukas, J; Holm, K

    1999-01-01

    The members of the 'pocket protein' family, comprising the retinoblastoma tumor suppressor (pRB) and its relatives, p107 and p130, negatively regulate cell proliferation and modulate fundamental biological processes including embryonic development, differentiation, homeostatic tissue renewal...

  4. Ciência, técnica e cultura: relações entre risco e práticas de saúde Science, technique, and culture: relations between risk and health practices

    Directory of Open Access Journals (Sweden)

    Dina Czeresnia

    2004-04-01

    Full Text Available Este artigo tem como objetivo discutir conseqüências culturais dos discursos e práticas voltados à capacitação dos sujeitos para a escolha racional e informada de riscos, calculados com base no conhecimento científico. O conceito de risco epidemiológico é um dos elementos centrais deste processo, especialmente no contexto das práticas de saúde. Inicialmente é apresentada uma breve caracterização do conceito de risco epidemiológico, ressaltando que, como modelo abstrato, reduz a complexidade dos fenômenos que estuda. A apreensão da realidade mediante essa abstração gera valores e significados. A reflexão de Canguilhem sobre as relações entre ciência, técnica e vida é retomada com a perspectiva de aprofundar a compreensão das conseqüências culturais produzidas, que contribuem para a transformação das concepções clássicas de individualidade, autonomia e sociabilidade. Temas vitais cruciais, como individualidade, alteridade, relação com a morte, estão presentes (ocultos nas questões que envolvem a nuclearidade do risco no mundo atual.This article discusses the cultural consequences of discourses and practices aimed at training subjects for a rational, informed choice in relation to risks, calculated on the basis of scientific knowledge. The epidemiological risk concept is a central element in this process, especially in the context of health practices. The article begins by briefly characterizing the epidemiological risk concept, emphasizing that as an abstract model, it reduces the complexity of the phenomena it studies. Grasping reality through this abstraction generates values and meanings. Canguilhem's reflection on the relations between science, technique, and life is further discussed from the perspective of deepening an understanding of the cultural consequences of this process, contributing to the transformation of classical concepts of individuality, autonomy, and sociability. Such vital themes as

  5. A Structural Study of Escherichia coli Cells Using an In Situ Liquid Chamber TEM Technology

    Directory of Open Access Journals (Sweden)

    Yibing Wang

    2015-01-01

    Full Text Available Studying cell microstructures and their behaviors under living conditions has been a challenging subject in microbiology. In this work, in situ liquid chamber TEM was used to study structures of Escherichia coli cells in aqueous solutions at a nanometer-scale resolution. Most of the cells remained intact under electron beam irradiation, and nanoscale structures were observed during the TEM imaging. The analysis revealed structures of pili surrounding the E. coli cells; the movements of the pili in the liquid were also observed during the in situ tests. This technology also allowed the observation of features of the nucleoid in the E. coli cells. Overall, in situ TEM can be applied as a valuable tool to study real-time microscopic structures and processes in microbial cells residing in native aqueous solutions.

  6. Analysis and design of a coupled coaxial line TEM resonator for magnetic resonance imaging

    International Nuclear Information System (INIS)

    Benahmed, Nasreddine; Feham, Mohammed; Khelif, M'Hamed

    2006-01-01

    In this paper, we have successfully realized a numerical tool to analyse and to design an n-element unloaded coaxial line transverse electromagnetic (TEM) resonator. This numerical tool allows the determination of the primary parameters, matrices [L], [C] and [R], and simulates the frequency response of S 11 at the RF port of the designed TEM resonator. The frequency response permits evaluation of the unloaded quality factor Q 0 . As an application, we present the analysis and the design of an eight-element unloaded TEM resonator for animal studies at 4.7 T. The simulated performance has a -62.81 dB minimum reflection and a quality factor of 260 around 200 MHz

  7. Speciation of uranium in minerals by Sem, Tem, μ-PIXE, XPS and XAFS

    International Nuclear Information System (INIS)

    Toshihiko Ohnuki; Hiroshi Isobe; Tomihiro Kamiya; Takuro Sakai; Takashi Murakami

    2001-01-01

    Many kinds of electromagnetic waves and particle beams are used as analytical probes for the investigation of uranium-mineralogy and speciation. The representatives of the probes are SEM, TEM, μ-PIRE, XPS and XAFS. Each of these analytical probes has its own advantages and disadvantages. We have performed studies to compare the advantages and disadvantages on the basis of the analysis of the distribution and speciation of U containing rock samples collected at the Koongarra uranium deposit, Australia. The spatial resolutions of the probes are in the order of TEM>SEM, μ-PIXE>XFAS, XPS. The lower detection limits of the probes are in the order of μ-PIXE< TEM, SEM< XFAS, XPS. Oxidation state of U was determined by XFAS and XPS. These results indicate that combination of the above probes can give us sufficient data on U speciation not only in natural rock samples but in solid samples obtained in the laboratory. (authors)

  8. Observation of Pt-{100}-p(2×2-O reconstruction by an environmental TEM

    Directory of Open Access Journals (Sweden)

    Hengbo Li

    2016-06-01

    Full Text Available The surface structure of noble metal nanoparticles usually plays a crucial role during the catalytic process in the fields of energy and environment. It has been studied extensively by surface analytic methods, such as scanning tunneling microscopy. However, it is still challenging to secure a direct observation of the structural evolution of surfaces of nanocatalysts in reaction (gas and heating conditions at the atomic scale. Here we report an in-situ observation of atomic reconstruction on Pt {100} surfaces exposed to oxygen in an environmental transmission electron microscope (TEM. Our high-resolution TEM images revealed that Pt-{100}-p(2×2-O reconstruction occurs during the reaction between oxygen atoms and {100} facets. A reconstruction model was proposed, and TEM images simulated according to this model with different defocus values match the experimental results well.

  9. Nonlinear interplay of TEM and ITG turbulence and its effect on transport

    Science.gov (United States)

    Merz, F.; Jenko, F.

    2010-05-01

    The dominant source of anomalous transport in fusion plasmas on ion scales is turbulence driven by trapped electron modes (TEMs) and ion temperature gradient (ITG) modes. While the individual properties of each of these two instabilities and the corresponding microturbulence have been examined in detail in the past, the effects of a coexistence of the two modes and the phenomena of transitions between the TEM and ITG dominated regimes are not well studied. In many experimental situations, the temperature and density gradients support both microinstabilities simultaneously, so that transitional regimes are important for a detailed understanding of fusion plasmas. In this paper, this issue is addressed, using the gyrokinetic code GENE for a detailed investigation of the dominant and subdominant linear instabilities and the corresponding nonlinear system. A simple quasilinear model based on eigenvalue computations is presented which is shown to reproduce important features of the nonlinear TEM-ITG transition.

  10. Qualidade de vida do paciente submetido à Microcirurgia Endoscópica Transanal (TEM Quality of life after Transanal Endoscopic Microsurgery (TEM

    Directory of Open Access Journals (Sweden)

    Roberto da Silveira Moraes

    2007-03-01

    Full Text Available RACIONAL: A Microcirurgia Endoscópica Transanal (TEM é procedimento minimamente invasivo para o tratamento de tumores retais selecionados. Atualmente, existe crescente interesse médico na medida quantitativa da qualidade de vida. OBJETIVO: Avaliar a qualidade de vida dos pacientes submetidos a TEM no Serviço de Cirurgia do Aparelho Digestivo no Hospital de Clínicas da Universidade Federal do Paraná. MÉTODOS: Trata-se de um estudo observacional prospectivo e de coorte da avaliação da qualidade de vida após TEM. Trinta e quatro pacientes responderam a um questionário composto de 14 questões, abordando aspectos pós-operatórios e laborais. Dirigiam-se elas para levantar dados principalmente sobre: o consentimento informado; a dor experimentada após a operação; a capacidade de o paciente caminhar no período pós-operatório; o período para retorno às atividades habituais; a satisfação com a ausência de cicatriz pós-operatória; a incontinência no pós-operatório; se recomendaria a operação a um familiar ou conhecido. RESULTADOS: Todos os 34 pacientes relataram ter sido adequadamente informados sobre o procedimento. Ausência de dor pós-operatória foi observada em 82,5% e todos se mostraram capazes de deambular no 1º dia do pós-operatório. O retorno às atividades habituais deu-se em média sete dias após o procedimento. Somente cinco pacientes (14,70% apresentaram incontinência fecal transitória, não maior que uma semana. Três pacientes (8,82% necessitaram de re-internação, sendo dois por tumores residuais e outro por recidiva tumoral. Dois pacientes (5,88% referiram modificação temporária na vida sexual após a cirurgia e 97,05% indicariam a TEM a um familiar ou amigo. O período médio de internação foi de três dias. CONCLUSÃO: Os pacientes apresentaram boa evolução, com pouca dor pós-operatória, curto período de internação e baixo índice de complicações, mostrando satisfação e adequada

  11. The use of a resource-based relative value scale (RBRVS) to determine practice expense costs: a novel technique of practice management for the vascular surgeon.

    Science.gov (United States)

    Mabry, C D

    2001-03-01

    Vascular surgeons have had to contend with rising costs while their reimbursements have undergone steady reductions. The use of newer accounting techniques can help vascular surgeons better manage their practices, plan for future expansion, and control costs. This article reviews traditional accounting methods, together with activity-based costing (ABC) principles that have been used in the past for practice expense analysis. The main focus is on a new technique-resource-based costing (RBC)-which uses the widely available Resource-Based Relative Value Scale (RBRVS) as its basis. The RBC technique promises easier implementation as well as more flexibility in determining true costs of performing various procedures, as opposed to more traditional accounting methods. It is hoped that RBC will assist vascular surgeons in coping with decreasing reimbursement. Copyright 2001 by W.B. Saunders Company

  12. Anatomic study of the pelvis in carcinoma of the uterine cervix as related to the box technique

    International Nuclear Information System (INIS)

    Zunino, Silvia; Rosato, Otilio; Lucino, Sergio; Jauregui, Esteban; Rossi, Luis; Venencia, Daniel

    1999-01-01

    Purpose: To review the radiation therapy 'box' technique for cancer of the cervix by means of magnetic resonance imaging (MRI), lymphangiography, and anatomic studies on cadavers. Methods and Materials: From 1993 to 1996, the anatomic borders of the 'box' technique used at our Radiation Oncology Department--the superior border of the AP-PA fields at the inferior edge of L4; the inferior border at the inferior edge of the ischium; the lateral borders placed 2.5 cm outside of the bony pelvis rim; the anterior border of the lateral fields over the anterior edge of the pubic symphysis; and the posterior at the S2-S3 interspace - were reviewed in 35 sagittal MRI and 10 lymphangiographies of patients with FIGO IB (6), IIA (6), IIB (19), IIIB (3), and IVA (1). An anatomic revision was conducted on 30 cadavers to identify aortic bifurcation, lymphatic nodes, and uterus flexion. Results: In 50% of the patients with FIGO IB, the posterior border of the lateral field was inadequate to encompass the planning target volume (PTV), and in 67% with Stage IIA. In IIB, the anterior border was inadequate in 1 patient, and the posterior in 8 (42%). In IIB and IVA patients, the PTV was not encompassed. When correlating the anterior and posterior borders of the lateral field and the treatment volume in the 35 sagittal MRIs, the posterior border of the lateral field was inadequate in 49%, and the anterior border in 9% of the cases. According to the lymphangiography, the portals encompassed the external iliac nodes. Dissected female pelvises revealed that the aortic bifurcation occurred at the level of the inferior L4 edge in 80% of the cadavers. There was no correlation between uterus flexion in MRIs and in cadavers. Conclusion: The design of the lateral fields of the four-field technique for the irradiation of the uterine cervix based on anatomic bone references failed to encompass the planning-target volume in a significant number of patients

  13. 2.5D Modeling of TEM Data Applied to Hidrogeological Studies in PARANÁ Basin, Brazil

    Science.gov (United States)

    Bortolozo, C. A.; Porsani, J. L.; Santos, F. M.

    2013-12-01

    The transient electromagnetic method (TEM) is used all over the world and has shown great potential in hydrological, hazardous waste site characterization, mineral exploration, general geological mapping, and geophysical reconnaissance. However, the behavior of TEM fields are very complex and is not yet fully understood. Forward modeling is one of the most common and effective methods to understand the physical behavior and significance of the electromagnetics responses of a TEM sounding. Until now, there are a limited number of solutions for the 2D forward problem for TEM. More rare are the descriptions of a three-component response of a 3D source over 2D earth, which is the so-called 2.5D. The 2.5D approach is more realistic than the conventional 2D source previous used, once normally the source cannot be realistic represented for a 2D approximation (normally source are square loops). At present the 2.5D model represents the only way of interpreting TEM data in terms of a complex earth, due to the prohibitive amount of computer time and storage required for a full 3D model. In this work we developed a TEM modeling program for understanding the different responses and how the magnetic and electric fields, produced by loop sources at air-earth interface, behave in different geoelectrical distributions. The models used in the examples are proposed focusing hydrogeological studies, once the main objective of this work is for detecting different kinds of aquifers in Paraná sedimentary basin, in São Paulo State - Brazil. The program was developed in MATLAB, a widespread language very common in the scientific community.

  14. Aberration-corrected STEM/TEM imaging at 15 kV

    International Nuclear Information System (INIS)

    Sasaki, Takeo; Sawada, Hidetaka; Hosokawa, Fumio; Sato, Yuta; Suenaga, Kazu

    2014-01-01

    The performance of aberration-corrected (scanning) transmission electron microscopy (S/TEM) at an accelerating voltage of 15 kV was evaluated in a low-voltage microscope equipped with a cold-field emission gun and a higher-order aberration corrector. Aberrations up to the fifth order were corrected by the aberration measurement and auto-correction system using the diffractogram tableau method in TEM and Ronchigram analysis in STEM. TEM observation of nanometer-sized particles demonstrated that aberrations up to an angle of 50 mrad were compensated. A TEM image of Si[110] exhibited lattice fringes with a spacing of 0.192 nm, and the power spectrum of the image showed spots corresponding to distances of 0.111 nm. An annular dark-field STEM image of Si[110] showed lattice fringes of (111) and (22¯0) planes corresponding to lattice distances of 0.314 nm and 0.192 nm, respectively. At an accelerating voltage of 15 kV, the developed low-voltage microscope achieved atomic-resolution imaging with a small chromatic aberration and a large uniform phase. - Highlights: • Aberration-corrected STEM/TEM imaging at 15 kV demonstrated lattice fringes of Si[110] single crystal with a spacing of 0.192 nm. • To achieve this performance at a lower accelerating voltage, uniform phase area over 50 mrad is mandatory in Ronchigram and Diffractogram tableau. • This means a higher-order aberration of six-fold astigmatism should be compensated. • In addition, decreasing the effect of chromatic aberration plays an important role for improving the performance of linear scattering component at 15 kV TEM

  15. The breeding of a wheat mutant pollen-derived variety Chuanfu No.5 and the related techniques

    International Nuclear Information System (INIS)

    Xuan Pu; Yin Chunrong; Yue Chunfang; Qu Shihong

    2002-01-01

    With the treatment of 150 Gy 60 Co-γ irradiation to the dry F 1 (Mianyang 88-334 x 8811525) hybrid seeds and the donor plants chosen from MF 2 , wheat anther culture was made based on MW 14 and modified MS media and the pure diploid lines of MH 1 derived from anther pollen were obtained. In 1996, the new mutant line 6086 and its sibling lines, 6086 and 6087, were selected and bred successfully. In 2002, the mutant pollen-derived line 6086 was denominated as Chuanfu No.5 by Sichuan Crop Variety Identification Committee and became the first mutant variety via anther culture of wheat in Sichuan. The success of Chuanfu No.5 shown that combining radiation induction and anther technique could shorten the breeding period and increase the efficiency of breeding of wheat

  16. Formation and properties of epitaxial CdSe, ZnSe quantum dots. Conventional molecular beam epitaxy and related techniques

    International Nuclear Information System (INIS)

    Mahapatra, Suddhasatta

    2008-01-01

    This thesis systematically investigates three such alternative approaches, along with conventional MBE, with emphasis on the formation-mechanism of QDs, and optimization of their morphological and optical attributes. it is shown here that no distinct 3D islands are formed in MBE growth of CdSe on ZnSe. While CdSe heteroepitaxy occurs in the multilayer-mode at T G =300 C, a reentrant recovery of the layer-by-layer mode is reported in this thesis, for growth at T G D =230 C). The process steps of the third variant technique, developed in course of this work, are very similar to those of the previous one-the only alteration being the substitution of selenium with tellurium as the cap-forming-material. (orig.)

  17. The preclinical sheep model of high tibial osteotomy relating basic science to the clinics: standards, techniques and pitfalls.

    Science.gov (United States)

    Pape, Dietrich; Madry, Henning

    2013-01-01

    To develop a preclinical large animal model of high tibial osteotomy to study the effect of axial alignment on the lower extremity on specific issues of the knee joint, such as in articular cartilage repair, development of osteoarthritis and meniscal lesions. Preoperative planning, surgical procedure and postoperative care known from humans were adapted to develop a HTO model in the adult sheep. Thirty-five healthy, skeletally mature, female Merino sheep between 2 and 4 years of age underwent a HTO of their right tibia in a medial open-wedge technique inducing a normal (group 1) and an excessive valgus alignment (group 2) and a closed-wedge technique (group 3) inducing a varus alignment with the aim of elucidating the effect of limb alignment on cartilage repair in vivo. Animals were followed up for 6 months. Solid bone healing and maintenance of correction are most likely if the following surgical principles are respected: (1) medial and longitudinal approach to the proximal tibia; (2) biplanar osteotomy to increase initial rotatory stability regardless of the direction of correction; (3) small, narrow but long implant with locking screws; (4) posterior plate placement to avoid slope changes; (5) use of bicortical screws to account for the brittle bone of the tibial head and to avoid tibial head displacement. Although successful high tibial osteotomy in sheep is complex, the sheep may--because of its similarities with humans--serve as an elegant model to induce axial malalignment in a clinically relevant environment, and osteotomy healing under challenging mechanical conditions.

  18. Cognitive behavioral therapy in practice: therapist perceptions of techniques, outcome measures, practitioner qualifications, and relation to research.

    Science.gov (United States)

    Bohman, Benjamin; Santi, Alberto; Andersson, Gerhard

    2017-09-01

    Cognitive behavioral therapy (CBT) has a strong evidence base for several psychiatric disorders, however, it may be argued that currently there is no overall agreement on what counts as 'CBT'. One reason is that CBT is commonly perceived as encompassing a broad range of treatments, from purely cognitive to purely behavioral, making it difficult to arrive at a clear definition. The purpose of the present study was to explore practicing therapists' perceptions of CBT. Three hundred fifty members of two multi-disciplinary interest groups for CBT in Sweden participated. Mean age was 46 years, 68% were females, 63% psychologists and mean number of years of professional experience was 12 years. Participants completed a web-based survey including items covering various aspects of CBT practice. Overall, therapist perceptions of the extent to which different treatment techniques and procedures were consistent with CBT were in line with current evidence-based CBT protocols and practice guidelines, as were therapists' application of the techniques and procedures in their own practice. A majority of participants (78%) agreed that quality of life or level of functioning were the most important outcome measures for evaluating treatment success. Eighty percent of therapists believed that training in CBT at a basic level was a requirement for practicing CBT. There was a medium size Spearman correlation of r s= .46 between the perceived importance of research to practice and the extent to which participants kept themselves updated on research. Implications for training, quality assurance, and the effectiveness of CBT in clinical practice are discussed.

  19. In situ TEM observation of the growth and decomposition of monoclinic W18O49 nanowires

    International Nuclear Information System (INIS)

    Chen, C L; Mori, H

    2009-01-01

    The growth of monoclinic W 18 O 49 nanowires by heat treatment of a tungsten filament at ∼873 K and the decomposition of these nanowires under 200 keV electron irradiation at ∼1023 K have been investigated using in situ transmission electron microscopy (TEM). In situ TEM observation of the growth confirmed the vapor-solid growth mechanism of the monoclinic W 18 O 49 nanowires. In situ irradiation experiments revealed the formation of metallic bcc tungsten from monoclinic W 18 O 49 nanowires under 200 keV electron irradiation.

  20. Quantitative in situ TEM tensile testing of an individual nickel nanowire

    International Nuclear Information System (INIS)

    Lu Yang; Peng Cheng; Ganesan, Yogeeswaran; Lou Jun; Huang Jianyu

    2011-01-01

    In this paper, we have demonstrated the usage of a novel micro-mechanical device (MMD) to perform quantitative in situ tensile tests on individual metallic nanowires inside a transmission electron microscope (TEM). Our preliminary experiment on a 360 nm diameter nickel nanowire showed that the sample fractured at an engineering stress of ∼ 1.2 GPa and an engineering strain of ∼ 4%, which is consistent with earlier experiments performed inside a scanning electron microscope (SEM). With in situ high resolution TEM imaging and diffraction capabilities, this novel experimental set-up could provide unique opportunities to reveal the underlying deformation and damage mechanisms for metals at the nanoscale.